{"lab":{"_id":"69ad52a3de79e566650fb3a8","country":"PL","accr_number":"AB 726","accr_body":"PCA","address":"CENTRUM BADAWCZO-ROZWOJOWE, ul. Gen. Wł. Sikorskiego 2-8, 53-659 Wrocław, LABORATORIUM BADAŃ MATERIAŁOWYCH","categories":["materials","construction"],"city":"Wrocław","imported_at":"2026-03-08T10:42:43.265Z","methods_count":17,"name":"KGHM CUPRUM SP. Z O.O.","parse_status":"parsed","parse_version":2,"pdf_files":["AB_726.pdf"],"scope_summary":"","search_text":"kghm cuprum sp. z o.o. centrum badawczo-rozwojowe, ul. gen. wł. sikorskiego 2-8, 53-659 wrocław, laboratorium badań materiałowych other construction materials","status":"active","updated_at":"2026-03-08T14:51:37.314Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-13T08:10:42.959Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20726,podmiot.html","fields_of_testing":[{"codes":"J/5, J/31","pl":"Badania mechaniczne wyrobów budowlanych, skał","en":"Machanical tests of building products, rocks"},{"codes":"L/5,L/8","pl":"","en":""},{"codes":"N/5,N/8, N/31","pl":"","en":""},{"codes":"P/31","pl":"","en":""}],"issue":{"no":"18","date":"02.06.2026"},"parse_date":"2026-08-13T08:10:42.959Z","parse_source":"agent-claude-code","map_coord":[51.108978,17.032669],"map_geo":"nominatim-city","lab_locations":[{"name":"LABORATORIUM BADAŃ MATERIAŁOWYCH","address":"AB 726 ul. Pracka 3","city":null,"postal":null},{"name":"Pracownia Badania Fizykomechanicznych Własności Skał, Betonu, Gruntów i Podsadzki (PS)","address":"ul. Pracka 3, 54-066 Wrocław","city":"Wrocław","postal":"54-066"},{"name":"Pracownia Badania i Monitorowania Obudów Górniczych (PO)","address":"ul. Pracka 3, 54-066 Wrocław","city":"Wrocław","postal":"54-066"},{"name":"Laboratorium Badań Materiałowych; Pracownia Badania Fizykomechanicznych Własności Skał, Betonu, Gruntów i Podsadzki (PS)","address":null,"city":null,"postal":null},{"name":"Laboratorium Badań Materiałowych; Pracownia Badania i Monitorowania Obudów Górniczych (PO)","address":null,"city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka5","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/13/95e34b4bcddc70888e4f772682f3bad2/AB%20726.pdf","has_en":true,"category_counts":{"materials":8,"other":6,"construction":3},"category_scores":{"materials":3.76,"other":2.12,"construction":0.53},"has_zh":true,"lab_locations_zh":[{"name":"LABORATORIUM BADAŃ MATERIAŁOWYCH","address":"AB 726 ul. Pracka 3","city":null,"postal":null},{"name":"Pracownia Badania Fizykomechanicznych Własności Skał, Betonu, Gruntów i Podsadzki (PS)","address":"ul. Pracka 3, 54-066 Wrocław","city":"Wrocław","postal":"54-066"},{"name":"Pracownia Badania i Monitorowania Obudów Górniczych (PO)","address":"ul. Pracka 3, 54-066 Wrocław","city":"Wrocław","postal":"54-066"},{"name":"材料检验实验室；岩石、混凝土、土体与充填材料物理力学性能检验室（PS）","address":null,"city":null,"postal":null},{"name":"材料检验实验室；矿用支架检验与监测室（PO）","address":null,"city":null,"postal":null}]},"methods":[{"_id":"6a7d7c020636ba417e41c183","lab_id":"69ad52a3de79e566650fb3a8","country":"PL","accr_number":"AB 726","accr_body":"PCA","test_object":"Skały zwięzłe","methodology":"Wytrzymałość na ściskanie","parameters":[{"name":"Zakres obciążeń","range":"(10 - 1500) kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na ściskanie\nZakres obciążeń (10 - 1500) kN","reference":"PN-G-04303:1997","norm_bases":["PN-G-04303:1997"],"lab_section":"Laboratorium Badań Materiałowych; Pracownia Badania Fizykomechanicznych Własności Skał, Betonu, Gruntów i Podsadzki (PS)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Skały zwięzłe Wytrzymałość na ściskanie\nZakres obciążeń (10 - 1500) kN PN-G-04303:1997 Skaly zwiezle Wytrzymalosc na sciskanie\nZakres obciazen (10 - 1500) kN PN-G-04303:1997","categories":["other"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Materials Testing Laboratory; Laboratory for Testing Physical and Mechanical Properties of Rocks, Concrete, Soils and Backfill (PS)","methodology_en":"Compressive strength","parameters_en":[{"name":"Load range","range":"(10 - 1500) kN"}],"search_en":"Compact rocks Compressive strength Materials Testing Laboratory; Laboratory for Testing Physical and Mechanical Properties of Rocks, Concrete, Soils and Backfill (PS) Load range PN-G-04303:1997","test_object_en":"Compact rocks","methodology_zh":"抗压强度","search_zh":"致密岩石 抗压强度 材料检验实验室；岩石、混凝土、土体与充填材料物理力学性能检验室（PS） 载荷范围 PN-G-04303:1997","parameters_zh":[{"name":"载荷范围","range":"(10 - 1500) kN"}],"lab_section_zh":"材料检验实验室；岩石、混凝土、土体与充填材料物理力学性能检验室（PS）","test_object_zh":"致密岩石"},{"_id":"6a7d7c020636ba417e41c184","lab_id":"69ad52a3de79e566650fb3a8","country":"PL","accr_number":"AB 726","accr_body":"PCA","test_object":"Skały zwięzłe","methodology":"Wytrzymałość na rozciąganie","parameters":[{"name":"Zakres obciążeń","range":"(10 - 100) kN"}],"technique":"Metoda poprzecznego ściskania","techniques":["Metoda poprzecznego ściskania"],"computed":[],"activity":"Wytrzymałość na rozciąganie\nZakres obciążeń (10 - 100) kN\nMetoda poprzecznego ściskania","reference":"PN-G-04302:1997","norm_bases":["PN-G-04302:1997"],"lab_section":"Laboratorium Badań Materiałowych; Pracownia Badania Fizykomechanicznych Własności Skał, Betonu, Gruntów i Podsadzki (PS)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Skały zwięzłe Wytrzymałość na rozciąganie\nZakres obciążeń (10 - 100) kN\nMetoda poprzecznego ściskania PN-G-04302:1997 Skaly zwiezle Wytrzymalosc na rozciaganie\nZakres obciazen (10 - 100) kN\nMetoda poprzecznego sciskania PN-G-04302:1997","categories":["other"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Materials Testing Laboratory; Laboratory for Testing Physical and Mechanical Properties of Rocks, Concrete, Soils and Backfill (PS)","methodology_en":"Tensile strength","parameters_en":[{"name":"Load range","range":"(10 - 100) kN"}],"search_en":"Compact rocks Tensile strength Transverse compression method Materials Testing Laboratory; Laboratory for Testing Physical and Mechanical Properties of Rocks, Concrete, Soils and Backfill (PS) Load range PN-G-04302:1997","technique_en":"Transverse compression method","test_object_en":"Compact rocks","parameters_zh":[{"name":"载荷范围","range":"(10 - 100) kN"}],"search_zh":"致密岩石 抗拉强度 材料检验实验室；岩石、混凝土、土体与充填材料物理力学性能检验室（PS） 载荷范围 PN-G-04302:1997","methodology_zh":"抗拉强度","lab_section_zh":"材料检验实验室；岩石、混凝土、土体与充填材料物理力学性能检验室（PS）","test_object_zh":"致密岩石"},{"_id":"6a7d7c020636ba417e41c185","lab_id":"69ad52a3de79e566650fb3a8","country":"PL","accr_number":"AB 726","accr_body":"PCA","test_object":"Skały zwięzłe","methodology":"Wytrzymałość na ścinanie proste","parameters":[{"name":"Zakres obciążeń","range":"(5 - 100) kN"}],"technique":"Metoda z użyciem próbek w postaci krążka","techniques":["Metoda z użyciem próbek w postaci krążka"],"computed":[],"activity":"Wytrzymałość na ścinanie proste\nZakres obciążeń (5 - 100) kN\nMetoda z użyciem próbek w postaci krążka","reference":"PN-G-04304:1997+Az1:1999","norm_bases":["PN-G-04304:1997+Az1:1999"],"lab_section":"Laboratorium Badań Materiałowych; Pracownia Badania Fizykomechanicznych Własności Skał, Betonu, Gruntów i Podsadzki (PS)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Skały zwięzłe Wytrzymałość na ścinanie proste\nZakres obciążeń (5 - 100) kN\nMetoda z użyciem próbek w postaci krążka PN-G-04304:1997+Az1:1999 Skaly zwiezle Wytrzymalosc na scinanie proste\nZakres obciazen (5 - 100) kN\nMetoda z uzyciem probek w postaci krazka PN-G-04304:1997+Az1:1999","categories":["other"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Materials Testing Laboratory; Laboratory for Testing Physical and Mechanical Properties of Rocks, Concrete, Soils and Backfill (PS)","methodology_en":"Simple shear strength","parameters_en":[{"name":"Load range","range":"(5 - 100) kN"}],"search_en":"Compact rocks Simple shear strength Method using disc-shaped specimens Materials Testing Laboratory; Laboratory for Testing Physical and Mechanical Properties of Rocks, Concrete, Soils and Backfill (PS) Load range PN-G-04304:1997+Az1:1999","technique_en":"Method using disc-shaped specimens","test_object_en":"Compact rocks","parameters_zh":[{"name":"载荷范围","range":"(5 - 100) kN"}],"search_zh":"致密岩石 材料检验实验室；岩石、混凝土、土体与充填材料物理力学性能检验室（PS） 载荷范围 PN-G-04304:1997+Az1:1999","lab_section_zh":"材料检验实验室；岩石、混凝土、土体与充填材料物理力学性能检验室（PS）","test_object_zh":"致密岩石"},{"_id":"6a7d7c020636ba417e41c186","lab_id":"69ad52a3de79e566650fb3a8","country":"PL","accr_number":"AB 726","accr_body":"PCA","test_object":"Skały zwięzłe","methodology":"Wytrzymałość na zginanie","parameters":[{"name":"Zakres obciążeń","range":"(5 - 100) kN"}],"technique":"Metoda z użyciem próbek w postaci krążka","techniques":["Metoda z użyciem próbek w postaci krążka"],"computed":[],"activity":"Wytrzymałość na zginanie\nZakres obciążeń (5 - 100) kN\nMetoda z użyciem próbek w postaci krążka","reference":"PN-G-04306:1998","norm_bases":["PN-G-04306:1998"],"lab_section":"Laboratorium Badań Materiałowych; Pracownia Badania Fizykomechanicznych Własności Skał, Betonu, Gruntów i Podsadzki (PS)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Skały zwięzłe Wytrzymałość na zginanie\nZakres obciążeń (5 - 100) kN\nMetoda z użyciem próbek w postaci krążka PN-G-04306:1998 Skaly zwiezle Wytrzymalosc na zginanie\nZakres obciazen (5 - 100) kN\nMetoda z uzyciem probek w postaci krazka PN-G-04306:1998","categories":["other"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Materials Testing Laboratory; Laboratory for Testing Physical and Mechanical Properties of Rocks, Concrete, Soils and Backfill (PS)","methodology_en":"Flexural strength","parameters_en":[{"name":"Load range","range":"(5 - 100) kN"}],"search_en":"Compact rocks Flexural strength Method using disc-shaped specimens Materials Testing Laboratory; Laboratory for Testing Physical and Mechanical Properties of Rocks, Concrete, Soils and Backfill (PS) Load range PN-G-04306:1998","technique_en":"Method using disc-shaped specimens","test_object_en":"Compact rocks","methodology_zh":"抗弯强度","search_zh":"致密岩石 抗弯强度 材料检验实验室；岩石、混凝土、土体与充填材料物理力学性能检验室（PS） 载荷范围 PN-G-04306:1998","parameters_zh":[{"name":"载荷范围","range":"(5 - 100) kN"}],"lab_section_zh":"材料检验实验室；岩石、混凝土、土体与充填材料物理力学性能检验室（PS）","test_object_zh":"致密岩石"},{"_id":"6a7d7c020636ba417e41c187","lab_id":"69ad52a3de79e566650fb3a8","country":"PL","accr_number":"AB 726","accr_body":"PCA","test_object":"Beton","methodology":"Wytrzymałość na ściskanie","parameters":[{"name":"Zakres obciążeń","range":"(200 - 2000) kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na ściskanie\nZakres obciążeń (200 - 2000) kN","reference":"PN-EN 12390-3:2019-07","norm_bases":["PN-EN 12390-3:2019-07"],"lab_section":"Laboratorium Badań Materiałowych; Pracownia Badania Fizykomechanicznych Własności Skał, Betonu, Gruntów i Podsadzki (PS)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Wytrzymałość na ściskanie\nZakres obciążeń (200 - 2000) kN PN-EN 12390-3:2019-07 Beton Wytrzymalosc na sciskanie\nZakres obciazen (200 - 2000) kN PN-EN 12390-3:2019-07","categories":["construction"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Materials Testing Laboratory; Laboratory for Testing Physical and Mechanical Properties of Rocks, Concrete, Soils and Backfill (PS)","methodology_en":"Compressive strength","parameters_en":[{"name":"Load range","range":"(200 - 2000) kN"}],"search_en":"Concrete Compressive strength Materials Testing Laboratory; Laboratory for Testing Physical and Mechanical Properties of Rocks, Concrete, Soils and Backfill (PS) Load range PN-EN 12390-3:2019-07","test_object_en":"Concrete","methodology_zh":"抗压强度","search_zh":"混凝土 抗压强度 材料检验实验室；岩石、混凝土、土体与充填材料物理力学性能检验室（PS） 载荷范围 PN-EN 12390-3:2019-07","test_object_zh":"混凝土","parameters_zh":[{"name":"载荷范围","range":"(200 - 2000) kN"}],"lab_section_zh":"材料检验实验室；岩石、混凝土、土体与充填材料物理力学性能检验室（PS）"},{"_id":"6a7d7c020636ba417e41c188","lab_id":"69ad52a3de79e566650fb3a8","country":"PL","accr_number":"AB 726","accr_body":"PCA","test_object":"Materiały podsadzkowe pochodzenia naturalnego i przemysłowego","methodology":"Zawartość ziarn o wymiarach poniżej","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość ziarn o wymiarach poniżej","reference":"PN-G-11010:1993, p.5.3.1","norm_bases":["PN-G-11010:1993, p.5.3.1"],"lab_section":"Laboratorium Badań Materiałowych; Pracownia Badania Fizykomechanicznych Własności Skał, Betonu, Gruntów i Podsadzki (PS)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały podsadzkowe pochodzenia naturalnego i przemysłowego Zawartość ziarn o wymiarach poniżej PN-G-11010:1993, p.5.3.1 Materialy podsadzkowe pochodzenia naturalnego i przemyslowego Zawartosc ziarn o wymiarach ponizej PN-G-11010:1993, p.5.3.1","categories":["materials"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Materials Testing Laboratory; Laboratory for Testing Physical and Mechanical Properties of Rocks, Concrete, Soils and Backfill (PS)","methodology_en":"Content of grains with dimensions below","search_en":"Backfill materials of natural and industrial origin Content of grains with dimensions below Materials Testing Laboratory; Laboratory for Testing Physical and Mechanical Properties of Rocks, Concrete, Soils and Backfill (PS) PN-G-11010:1993, p.5.3.1","test_object_en":"Backfill materials of natural and industrial origin","lab_section_zh":"材料检验实验室；岩石、混凝土、土体与充填材料物理力学性能检验室（PS）","search_zh":"天然与工业来源的充填材料 材料检验实验室；岩石、混凝土、土体与充填材料物理力学性能检验室（PS） PN-G-11010:1993, p.5.3.1","test_object_zh":"天然与工业来源的充填材料"},{"_id":"6a7d7c020636ba417e41c189","lab_id":"69ad52a3de79e566650fb3a8","country":"PL","accr_number":"AB 726","accr_body":"PCA","test_object":"Materiały podsadzkowe pochodzenia naturalnego i przemysłowego","methodology":"0,1 mm","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"0,1 mm","reference":"PN-G-11010:1993, p.5.3.1","norm_bases":["PN-G-11010:1993, p.5.3.1"],"lab_section":"Laboratorium Badań Materiałowych; Pracownia Badania Fizykomechanicznych Własności Skał, Betonu, Gruntów i Podsadzki (PS)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały podsadzkowe pochodzenia naturalnego i przemysłowego 0,1 mm PN-G-11010:1993, p.5.3.1 Materialy podsadzkowe pochodzenia naturalnego i przemyslowego 0,1 mm PN-G-11010:1993, p.5.3.1","categories":["materials"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Materials Testing Laboratory; Laboratory for Testing Physical and Mechanical Properties of Rocks, Concrete, Soils and Backfill (PS)","methodology_en":"0,1 mm","search_en":"Backfill materials of natural and industrial origin 0,1 mm Materials Testing Laboratory; Laboratory for Testing Physical and Mechanical Properties of Rocks, Concrete, Soils and Backfill (PS) PN-G-11010:1993, p.5.3.1","test_object_en":"Backfill materials of natural and industrial origin","lab_section_zh":"材料检验实验室；岩石、混凝土、土体与充填材料物理力学性能检验室（PS）","search_zh":"天然与工业来源的充填材料 材料检验实验室；岩石、混凝土、土体与充填材料物理力学性能检验室（PS） PN-G-11010:1993, p.5.3.1","test_object_zh":"天然与工业来源的充填材料"},{"_id":"6a7d7c020636ba417e41c18a","lab_id":"69ad52a3de79e566650fb3a8","country":"PL","accr_number":"AB 726","accr_body":"PCA","test_object":"Materiały podsadzkowe pochodzenia naturalnego i przemysłowego","methodology":"Najwyższy wymiar ziarna","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Najwyższy wymiar ziarna","reference":"PN-G-11010:1993, p.5.3.2","norm_bases":["PN-G-11010:1993, p.5.3.2"],"lab_section":"Laboratorium Badań Materiałowych; Pracownia Badania Fizykomechanicznych Własności Skał, Betonu, Gruntów i Podsadzki (PS)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały podsadzkowe pochodzenia naturalnego i przemysłowego Najwyższy wymiar ziarna PN-G-11010:1993, p.5.3.2 Materialy podsadzkowe pochodzenia naturalnego i przemyslowego Najwyzszy wymiar ziarna PN-G-11010:1993, p.5.3.2","categories":["materials"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Materials Testing Laboratory; Laboratory for Testing Physical and Mechanical Properties of Rocks, Concrete, Soils and Backfill (PS)","methodology_en":"Maximum grain size","search_en":"Backfill materials of natural and industrial origin Maximum grain size Materials Testing Laboratory; Laboratory for Testing Physical and Mechanical Properties of Rocks, Concrete, Soils and Backfill (PS) PN-G-11010:1993, p.5.3.2","test_object_en":"Backfill materials of natural and industrial origin","lab_section_zh":"材料检验实验室；岩石、混凝土、土体与充填材料物理力学性能检验室（PS）","search_zh":"天然与工业来源的充填材料 材料检验实验室；岩石、混凝土、土体与充填材料物理力学性能检验室（PS） PN-G-11010:1993, p.5.3.2","test_object_zh":"天然与工业来源的充填材料"},{"_id":"6a7d7c020636ba417e41c18b","lab_id":"69ad52a3de79e566650fb3a8","country":"PL","accr_number":"AB 726","accr_body":"PCA","test_object":"Materiały podsadzkowe pochodzenia naturalnego i przemysłowego","methodology":"Ściśliwość dla ciśnienia (0 - 25) MPa, Ściśliwość","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ściśliwość dla ciśnienia (0 - 25) MPa, Ściśliwość","reference":"PN-G-11010:1993, p.5.3.3","norm_bases":["PN-G-11010:1993, p.5.3.3"],"lab_section":"Laboratorium Badań Materiałowych; Pracownia Badania Fizykomechanicznych Własności Skał, Betonu, Gruntów i Podsadzki (PS)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały podsadzkowe pochodzenia naturalnego i przemysłowego Ściśliwość dla ciśnienia (0 - 25) MPa, Ściśliwość PN-G-11010:1993, p.5.3.3 Materialy podsadzkowe pochodzenia naturalnego i przemyslowego Scisliwosc dla cisnienia (0 - 25) MPa, Scisliwosc PN-G-11010:1993, p.5.3.3","categories":["materials"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Materials Testing Laboratory; Laboratory for Testing Physical and Mechanical Properties of Rocks, Concrete, Soils and Backfill (PS)","methodology_en":"Compressibility for pressure (0 - 25) MPa, Compressibility","search_en":"Backfill materials of natural and industrial origin Compressibility for pressure (0 - 25) MPa, Compressibility Materials Testing Laboratory; Laboratory for Testing Physical and Mechanical Properties of Rocks, Concrete, Soils and Backfill (PS) PN-G-11010:1993, p.5.3.3","test_object_en":"Backfill materials of natural and industrial origin","lab_section_zh":"材料检验实验室；岩石、混凝土、土体与充填材料物理力学性能检验室（PS）","search_zh":"天然与工业来源的充填材料 材料检验实验室；岩石、混凝土、土体与充填材料物理力学性能检验室（PS） PN-G-11010:1993, p.5.3.3","test_object_zh":"天然与工业来源的充填材料"},{"_id":"6a7d7c020636ba417e41c18c","lab_id":"69ad52a3de79e566650fb3a8","country":"PL","accr_number":"AB 726","accr_body":"PCA","test_object":"Materiały podsadzkowe pochodzenia naturalnego i przemysłowego","methodology":"Wodoprzepuszczalność","parameters":[{"name":"Zakres","range":"(0,0004 - 0,05) cm/s"}],"technique":null,"techniques":[],"computed":[],"activity":"Wodoprzepuszczalność\nZakres (0,0004 - 0,05) cm/s","reference":"PN-G-11010:1993, p.5.3.4","norm_bases":["PN-G-11010:1993, p.5.3.4"],"lab_section":"Laboratorium Badań Materiałowych; Pracownia Badania Fizykomechanicznych Własności Skał, Betonu, Gruntów i Podsadzki (PS)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały podsadzkowe pochodzenia naturalnego i przemysłowego Wodoprzepuszczalność\nZakres (0,0004 - 0,05) cm/s PN-G-11010:1993, p.5.3.4 Materialy podsadzkowe pochodzenia naturalnego i przemyslowego Wodoprzepuszczalnosc\nZakres (0,0004 - 0,05) cm/s PN-G-11010:1993, p.5.3.4","categories":["materials"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Materials Testing Laboratory; Laboratory for Testing Physical and Mechanical Properties of Rocks, Concrete, Soils and Backfill (PS)","methodology_en":"Water permeability","parameters_en":[{"name":"Range","range":"(0,0004 - 0,05) cm/s"}],"search_en":"Backfill materials of natural and industrial origin Water permeability Materials Testing Laboratory; Laboratory for Testing Physical and Mechanical Properties of Rocks, Concrete, Soils and Backfill (PS) Range PN-G-11010:1993, p.5.3.4","test_object_en":"Backfill materials of natural and industrial origin","parameters_zh":[{"name":"范围","range":"(0,0004 - 0,05) cm/s"}],"search_zh":"天然与工业来源的充填材料 材料检验实验室；岩石、混凝土、土体与充填材料物理力学性能检验室（PS） 范围 PN-G-11010:1993, p.5.3.4","lab_section_zh":"材料检验实验室；岩石、混凝土、土体与充填材料物理力学性能检验室（PS）","test_object_zh":"天然与工业来源的充填材料"},{"_id":"6a7d7c020636ba417e41c18d","lab_id":"69ad52a3de79e566650fb3a8","country":"PL","accr_number":"AB 726","accr_body":"PCA","test_object":"Materiały podsadzkowe pochodzenia naturalnego i przemysłowego","methodology":"Rozmywalność","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Rozmywalność","reference":"PN-G-11010:1993, p.5.3.5","norm_bases":["PN-G-11010:1993, p.5.3.5"],"lab_section":"Laboratorium Badań Materiałowych; Pracownia Badania Fizykomechanicznych Własności Skał, Betonu, Gruntów i Podsadzki (PS)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały podsadzkowe pochodzenia naturalnego i przemysłowego Rozmywalność PN-G-11010:1993, p.5.3.5 Materialy podsadzkowe pochodzenia naturalnego i przemyslowego Rozmywalnosc PN-G-11010:1993, p.5.3.5","categories":["materials"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Materials Testing Laboratory; Laboratory for Testing Physical and Mechanical Properties of Rocks, Concrete, Soils and Backfill (PS)","methodology_en":"Slaking","search_en":"Backfill materials of natural and industrial origin Slaking Materials Testing Laboratory; Laboratory for Testing Physical and Mechanical Properties of Rocks, Concrete, Soils and Backfill (PS) PN-G-11010:1993, p.5.3.5","test_object_en":"Backfill materials of natural and industrial origin","lab_section_zh":"材料检验实验室；岩石、混凝土、土体与充填材料物理力学性能检验室（PS）","search_zh":"天然与工业来源的充填材料 材料检验实验室；岩石、混凝土、土体与充填材料物理力学性能检验室（PS） PN-G-11010:1993, p.5.3.5","test_object_zh":"天然与工业来源的充填材料"},{"_id":"6a7d7c020636ba417e41c18e","lab_id":"69ad52a3de79e566650fb3a8","country":"PL","accr_number":"AB 726","accr_body":"PCA","test_object":"Materiały podsadzkowe pochodzenia naturalnego i przemysłowego","methodology":"Gęstość nasypowa","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Gęstość nasypowa","reference":"PN-G-11010:1993, p.5.3.6","norm_bases":["PN-G-11010:1993, p.5.3.6"],"lab_section":"Laboratorium Badań Materiałowych; Pracownia Badania Fizykomechanicznych Własności Skał, Betonu, Gruntów i Podsadzki (PS)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały podsadzkowe pochodzenia naturalnego i przemysłowego Gęstość nasypowa PN-G-11010:1993, p.5.3.6 Materialy podsadzkowe pochodzenia naturalnego i przemyslowego Gestosc nasypowa PN-G-11010:1993, p.5.3.6","categories":["materials"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Materials Testing Laboratory; Laboratory for Testing Physical and Mechanical Properties of Rocks, Concrete, Soils and Backfill (PS)","methodology_en":"Bulk density","search_en":"Backfill materials of natural and industrial origin Bulk density Materials Testing Laboratory; Laboratory for Testing Physical and Mechanical Properties of Rocks, Concrete, Soils and Backfill (PS) PN-G-11010:1993, p.5.3.6","test_object_en":"Backfill materials of natural and industrial origin","methodology_zh":"堆积密度","search_zh":"天然与工业来源的充填材料 堆积密度 材料检验实验室；岩石、混凝土、土体与充填材料物理力学性能检验室（PS） PN-G-11010:1993, p.5.3.6","lab_section_zh":"材料检验实验室；岩石、混凝土、土体与充填材料物理力学性能检验室（PS）","test_object_zh":"天然与工业来源的充填材料"},{"_id":"6a7d7c020636ba417e41c18f","lab_id":"69ad52a3de79e566650fb3a8","country":"PL","accr_number":"AB 726","accr_body":"PCA","test_object":"Materiały podsadzkowe pochodzenia naturalnego i przemysłowego","methodology":"Pobieranie próbek","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek","reference":"PN-G-11010:1993, p.5.2","norm_bases":["PN-G-11010:1993, p.5.2"],"lab_section":"Laboratorium Badań Materiałowych; Pracownia Badania Fizykomechanicznych Własności Skał, Betonu, Gruntów i Podsadzki (PS)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały podsadzkowe pochodzenia naturalnego i przemysłowego Pobieranie próbek PN-G-11010:1993, p.5.2 Materialy podsadzkowe pochodzenia naturalnego i przemyslowego Pobieranie probek PN-G-11010:1993, p.5.2","categories":["materials"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Materials Testing Laboratory; Laboratory for Testing Physical and Mechanical Properties of Rocks, Concrete, Soils and Backfill (PS)","methodology_en":"Sampling","search_en":"Backfill materials of natural and industrial origin Sampling Materials Testing Laboratory; Laboratory for Testing Physical and Mechanical Properties of Rocks, Concrete, Soils and Backfill (PS) PN-G-11010:1993, p.5.2","test_object_en":"Backfill materials of natural and industrial origin","methodology_zh":"样品采集","search_zh":"天然与工业来源的充填材料 样品采集 材料检验实验室；岩石、混凝土、土体与充填材料物理力学性能检验室（PS） PN-G-11010:1993, p.5.2","lab_section_zh":"材料检验实验室；岩石、混凝土、土体与充填材料物理力学性能检验室（PS）","test_object_zh":"天然与工业来源的充填材料"},{"_id":"6a7d7c020636ba417e41c190","lab_id":"69ad52a3de79e566650fb3a8","country":"PL","accr_number":"AB 726","accr_body":"PCA","test_object":"Obudowa betonowa szybu","methodology":"Wytrzymałość betonu na ściskanie","parameters":[{"name":"Zakres","range":"(5 - 80) MPa"}],"technique":"Metoda ultradźwiękowa","techniques":["Metoda ultradźwiękowa"],"computed":[],"activity":"Wytrzymałość betonu na ściskanie\nZakres (5 - 80) MPa\nMetoda ultradźwiękowa","reference":"PB/LAB-02-003/01 pkt. 4.3.1 wyd. 3 z dnia 26.01.2009 r.","norm_bases":["PB/LAB-02-003/01 pkt. 4.3.1 wyd. 3 z dnia 26.01.2009 r."],"lab_section":"Laboratorium Badań Materiałowych; Pracownia Badania i Monitorowania Obudów Górniczych (PO)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Obudowa betonowa szybu Wytrzymałość betonu na ściskanie\nZakres (5 - 80) MPa\nMetoda ultradźwiękowa PB/LAB-02-003/01 pkt. 4.3.1 wyd. 3 z dnia 26.01.2009 r. Obudowa betonowa szybu Wytrzymalosc betonu na sciskanie\nZakres (5 - 80) MPa\nMetoda ultradzwiekowa PB/LAB-02-003/01 pkt. 4.3.1 wyd. 3 z dnia 26.01.2009 r.","categories":["construction"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Materials Testing Laboratory; Mine Support Testing and Monitoring Laboratory (PO)","methodology_en":"Compressive strength of concrete","parameters_en":[{"name":"Range","range":"(5 - 80) MPa"}],"search_en":"Concrete shaft lining Compressive strength of concrete Ultrasonic method Materials Testing Laboratory; Mine Support Testing and Monitoring Laboratory (PO) Range PB/LAB-02-003/01 pkt. 4.3.1 wyd. 3 z dnia 26.01.2009 r.","technique_en":"Ultrasonic method","test_object_en":"Concrete shaft lining","parameters_zh":[{"name":"范围","range":"(5 - 80) MPa"}],"search_zh":"超声法 材料检验实验室；矿用支架检验与监测室（PO） 范围 PB/LAB-02-003/01 pkt. 4.3.1 wyd. 3 z dnia 26.01.2009 r.","technique_zh":"超声法","lab_section_zh":"材料检验实验室；矿用支架检验与监测室（PO）"},{"_id":"6a7d7c020636ba417e41c191","lab_id":"69ad52a3de79e566650fb3a8","country":"PL","accr_number":"AB 726","accr_body":"PCA","test_object":"Obudowa betonowa szybu","methodology":"Wytrzymałość betonu na ściskanie","parameters":[{"name":"Zakres","range":"(5 - 60) MPa"}],"technique":"Metoda sklerometryczna","techniques":["Metoda sklerometryczna"],"computed":[],"activity":"Wytrzymałość betonu na ściskanie\nZakres (5 - 60) MPa\nMetoda sklerometryczna","reference":"PB/LAB-02-003/01: pkt. 4.3.2 wyd. 3 z dnia 26.01.2009 r. wyd. 3 z dnia 26.01.2009 r.","norm_bases":["PB/LAB-02-003/01: pkt. 4.3.2 wyd. 3 z dnia 26.01.2009 r. wyd. 3 z dnia 26.01.2009 r."],"lab_section":"Laboratorium Badań Materiałowych; Pracownia Badania i Monitorowania Obudów Górniczych (PO)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Obudowa betonowa szybu Wytrzymałość betonu na ściskanie\nZakres (5 - 60) MPa\nMetoda sklerometryczna PB/LAB-02-003/01: pkt. 4.3.2 wyd. 3 z dnia 26.01.2009 r. wyd. 3 z dnia 26.01.2009 r. Obudowa betonowa szybu Wytrzymalosc betonu na sciskanie\nZakres (5 - 60) MPa\nMetoda sklerometryczna PB/LAB-02-003/01: pkt. 4.3.2 wyd. 3 z dnia 26.01.2009 r. wyd. 3 z dnia 26.01.2009 r.","categories":["construction"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Materials Testing Laboratory; Mine Support Testing and Monitoring Laboratory (PO)","methodology_en":"Compressive strength of concrete","parameters_en":[{"name":"Range","range":"(5 - 60) MPa"}],"search_en":"Concrete shaft lining Compressive strength of concrete Sclerometric method Materials Testing Laboratory; Mine Support Testing and Monitoring Laboratory (PO) Range PB/LAB-02-003/01: pkt. 4.3.2 wyd. 3 z dnia 26.01.2009 r. wyd. 3 z dnia 26.01.2009 r.","technique_en":"Sclerometric method","test_object_en":"Concrete shaft lining","parameters_zh":[{"name":"范围","range":"(5 - 60) MPa"}],"search_zh":"材料检验实验室；矿用支架检验与监测室（PO） 范围 PB/LAB-02-003/01: pkt. 4.3.2 wyd. 3 z dnia 26.01.2009 r. wyd. 3 z dnia 26.01.2009 r.","lab_section_zh":"材料检验实验室；矿用支架检验与监测室（PO）"},{"_id":"6a7d7c020636ba417e41c192","lab_id":"69ad52a3de79e566650fb3a8","country":"PL","accr_number":"AB 726","accr_body":"PCA","test_object":"Obudowa tubingowa szybu","methodology":"Grubość ścianki","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Grubość ścianki","reference":"PB/LAB-02-003: pkt. 5 wyd. 3 z dnia 26.01.2009 r.","norm_bases":["PB/LAB-02-003: pkt. 5 wyd. 3 z dnia 26.01.2009 r."],"lab_section":"Laboratorium Badań Materiałowych; Pracownia Badania i Monitorowania Obudów Górniczych (PO)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Obudowa tubingowa szybu Grubość ścianki PB/LAB-02-003: pkt. 5 wyd. 3 z dnia 26.01.2009 r. Obudowa tubingowa szybu Grubosc scianki PB/LAB-02-003: pkt. 5 wyd. 3 z dnia 26.01.2009 r.","categories":["other"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Materials Testing Laboratory; Mine Support Testing and Monitoring Laboratory (PO)","methodology_en":"Wall thickness","search_en":"Tubbing shaft lining Wall thickness Materials Testing Laboratory; Mine Support Testing and Monitoring Laboratory (PO) PB/LAB-02-003: pkt. 5 wyd. 3 z dnia 26.01.2009 r.","test_object_en":"Tubbing shaft lining","lab_section_zh":"材料检验实验室；矿用支架检验与监测室（PO）","search_zh":"材料检验实验室；矿用支架检验与监测室（PO） PB/LAB-02-003: pkt. 5 wyd. 3 z dnia 26.01.2009 r."},{"_id":"6a7d7c020636ba417e41c193","lab_id":"69ad52a3de79e566650fb3a8","country":"PL","accr_number":"AB 726","accr_body":"PCA","test_object":"Obudowa tubingowa szybu","methodology":"","parameters":[{"name":"Zakres","range":"(30 - 130) mm"}],"technique":"Metoda ultradźwiękowa","techniques":["Metoda ultradźwiękowa"],"computed":[],"activity":"Zakres (30 - 130) mm\nMetoda ultradźwiękowa","reference":"wyd. 3 z dnia 26.01.2009 r.","norm_bases":["wyd. 3 z dnia 26.01.2009 r."],"lab_section":"Laboratorium Badań Materiałowych; Pracownia Badania i Monitorowania Obudów Górniczych (PO)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Obudowa tubingowa szybu Zakres (30 - 130) mm\nMetoda ultradźwiękowa wyd. 3 z dnia 26.01.2009 r. Obudowa tubingowa szybu Zakres (30 - 130) mm\nMetoda ultradzwiekowa wyd. 3 z dnia 26.01.2009 r.","categories":["other"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Materials Testing Laboratory; Mine Support Testing and Monitoring Laboratory (PO)","parameters_en":[{"name":"Range","range":"(30 - 130) mm"}],"search_en":"Tubbing shaft lining Ultrasonic method Materials Testing Laboratory; Mine Support Testing and Monitoring Laboratory (PO) Range wyd. 3 z dnia 26.01.2009 r.","technique_en":"Ultrasonic method","test_object_en":"Tubbing shaft lining","parameters_zh":[{"name":"范围","range":"(30 - 130) mm"}],"search_zh":"超声法 材料检验实验室；矿用支架检验与监测室（PO） 范围 wyd. 3 z dnia 26.01.2009 r.","technique_zh":"超声法","lab_section_zh":"材料检验实验室；矿用支架检验与监测室（PO）"}],"has_pdf":true}