{"lab":{"_id":"69ad52a3de79e566650fb3a6","country":"PL","accr_number":"AB 722","accr_body":"PCA","address":"W LUBACZOWIE, ul. Mickiewicza 45, 37-600 Lubaczów","categories":["water","environment","microbiology"],"city":"Lubaczów","imported_at":"2026-03-08T10:42:43.265Z","methods_count":22,"name":"POWIATOWA STACJA SANITARNO-EPIDEMIOLOGICZNA","parse_status":"parsed","parse_version":2,"pdf_files":["AB_722.pdf"],"scope_summary":"","search_text":"powiatowa stacja sanitarno-epidemiologiczna w lubaczowie, ul. mickiewicza 45, 37-600 lubaczów water automotive microbiology other pharma electronics environment","status":"active","updated_at":"2026-03-08T14:51:37.267Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-13T08:10:41.071Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20722,podmiot.html","fields_of_testing":[{"codes":"C/28; C/29","pl":"Badania chemiczne wody, wody do spożycia przez ludzi","en":"Chemical tests of water, drinking water"},{"codes":"G/33","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki szkodliwe – hałas)","en":"Tests concerning environmental engineering (environmental and climatic) – working environment (harmful factors – noise)"},{"codes":"K/3; K/28; K/29","pl":"Badania mikrobiologiczne obiektów i materiałów biologicznych przeznaczonych do badań, wody, wody do spożycia przez ludzi","en":"Microbiological tests of biological items and materials for testing, water, drinking water"},{"codes":"N/33/P","pl":"Badania właściwości fizycznych i pobieranie próbek – środowisko pracy (czynniki szkodliwe – powietrze)","en":"Tests of physical properties and sampling - working environment (harmful factors – air)"},{"codes":"N/28; N/29","pl":"Badania właściwości fizycznych wody, wody do spożycia przez ludzi","en":"Tests of physical properties of water, drinking water"},{"codes":"Q/29","pl":"Badania sensoryczne wody do spożycia przez ludzi","en":"Sensory tests of drinking water"}],"issue":{"no":"23","date":"06.05.2026"},"parse_date":"2026-08-13T08:10:41.071Z","parse_source":"agent-claude-code","map_coord":[50.161134,23.121244],"map_geo":"nominatim-street","lab_locations":[{"name":"Oddział Laboratoryjny","address":"ul. Mickiewicza 45, 37-600 Lubaczów","city":"Lubaczów","postal":"37-600"},{"name":"Pracownia Higieny Komunalnej","address":"ul. Mickiewicza 45, 37-600 Lubaczów","city":"Lubaczów","postal":"37-600"},{"name":"Pracownia Higieny Pracy","address":"ul. Mickiewicza 45, 37-600 Lubaczów","city":"Lubaczów","postal":"37-600"},{"name":"Pracownia Diagnostyki Mikrobiologicznej","address":"ul. Mickiewicza 45, 37-600 Lubaczów","city":"Lubaczów","postal":"37-600"},{"name":"Oddział Laboratoryjny; Pracownia Diagnostyki Mikrobiologicznej","address":null,"city":null,"postal":null},{"name":"Oddział Laboratoryjny; Pracownia Higieny Komunalnej","address":null,"city":null,"postal":null},{"name":"Oddział Laboratoryjny; Pracownia Higieny Pracy","address":null,"city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/13/d64e268944d94911ac8f2de45103a31a/AB%20722.pdf","has_en":true,"category_counts":{"water":15,"environment":6,"microbiology":3},"category_scores":{"water":9.38,"environment":1.5,"microbiology":0.38},"has_zh":true,"lab_locations_zh":[{"name":"Oddział Laboratoryjny","address":"ul. Mickiewicza 45, 37-600 Lubaczów","city":"Lubaczów","postal":"37-600"},{"name":"公共卫生室","address":"ul. Mickiewicza 45, 37-600 Lubaczów","city":"Lubaczów","postal":"37-600"},{"name":"Pracownia Higieny Pracy","address":"ul. Mickiewicza 45, 37-600 Lubaczów","city":"Lubaczów","postal":"37-600"},{"name":"Pracownia Diagnostyki Mikrobiologicznej","address":"ul. Mickiewicza 45, 37-600 Lubaczów","city":"Lubaczów","postal":"37-600"},{"name":"Oddział Laboratoryjny; Pracownia Diagnostyki Mikrobiologicznej","address":null,"city":null,"postal":null},{"name":"实验室分部；公共卫生检验室","address":null,"city":null,"postal":null},{"name":"实验室分部；劳动卫生检验室","address":null,"city":null,"postal":null}]},"methods":[{"_id":"6a7d7c010636ba417e41c15f","lab_id":"69ad52a3de79e566650fb3a6","country":"PL","accr_number":"AB 722","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Liczba bakterii grupy coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":"Oddział Laboratoryjny; Pracownia Higieny Komunalnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda, woda do spozycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Division; Municipal Hygiene Laboratory","methodology_en":"Coliform bacteria count","search_en":"Water, water intended for human consumption Coliform bacteria count Membrane filtration method Laboratory Division; Municipal Hygiene Laboratory PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water, water intended for human consumption","methodology_zh":"大肠菌群计数","search_zh":"水、生活饮用水 大肠菌群计数 膜过滤法 实验室分部；公共卫生检验室 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水","lab_section_zh":"实验室分部；公共卫生检验室"},{"_id":"6a7d7c010636ba417e41c160","lab_id":"69ad52a3de79e566650fb3a6","country":"PL","accr_number":"AB 722","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Liczba Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":"Oddział Laboratoryjny; Pracownia Higieny Komunalnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda, woda do spozycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Division; Municipal Hygiene Laboratory","methodology_en":"Escherichia coli count","search_en":"Water, water intended for human consumption Escherichia coli count Membrane filtration method Laboratory Division; Municipal Hygiene Laboratory PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water, water intended for human consumption","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"水、生活饮用水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 实验室分部；公共卫生检验室 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水","lab_section_zh":"实验室分部；公共卫生检验室"},{"_id":"6a7d7c010636ba417e41c161","lab_id":"69ad52a3de79e566650fb3a6","country":"PL","accr_number":"AB 722","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Liczba enterokoków kałowych","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba enterokoków kałowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":"Oddział Laboratoryjny; Pracownia Higieny Komunalnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Liczba enterokoków kałowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda, woda do spozycia przez ludzi Liczba enterokokow kalowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Division; Municipal Hygiene Laboratory","methodology_en":"Intestinal enterococci count","search_en":"Water, water intended for human consumption Intestinal enterococci count Membrane filtration method Laboratory Division; Municipal Hygiene Laboratory PN-EN ISO 7899-2:2004","technique_en":"Membrane filtration method","test_object_en":"Water, water intended for human consumption","methodology_zh":"粪肠球菌计数","search_zh":"水、生活饮用水 粪肠球菌计数 膜过滤法 实验室分部；公共卫生检验室 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水","lab_section_zh":"实验室分部；公共卫生检验室"},{"_id":"6a7d7c010636ba417e41c162","lab_id":"69ad52a3de79e566650fb3a6","country":"PL","accr_number":"AB 722","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w 22°C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w 22°C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Oddział Laboratoryjny; Pracownia Higieny Komunalnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 22°C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda, woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 22°C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Division; Municipal Hygiene Laboratory","methodology_en":"Total viable count at 22°C","search_en":"Water, water intended for human consumption Total viable count at 22°C Plate method (pour plate) Laboratory Division; Municipal Hygiene Laboratory PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water, water intended for human consumption","methodology_zh":"22°C 微生物总数","search_zh":"水、生活饮用水 22°C 微生物总数 平板法（倾注培养） 实验室分部；公共卫生检验室 PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水、生活饮用水","lab_section_zh":"实验室分部；公共卫生检验室"},{"_id":"6a7d7c010636ba417e41c163","lab_id":"69ad52a3de79e566650fb3a6","country":"PL","accr_number":"AB 722","accr_body":"PCA","test_object":"Woda","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Oddział Laboratoryjny; Pracownia Higieny Komunalnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Division; Municipal Hygiene Laboratory","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"search_en":"Water pH Potentiometric method Laboratory Division; Municipal Hygiene Laboratory Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"水 pH 值 电位法 实验室分部；公共卫生检验室 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水","lab_section_zh":"实验室分部；公共卫生检验室"},{"_id":"6a7d7c010636ba417e41c164","lab_id":"69ad52a3de79e566650fb3a6","country":"PL","accr_number":"AB 722","accr_body":"PCA","test_object":"Woda","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(147 – 2500) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (147 – 2500) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Oddział Laboratoryjny; Pracownia Higieny Komunalnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Przewodność elektryczna właściwa\nZakres (147 – 2500) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda Przewodnosc elektryczna wlasciwa\nZakres (147 – 2500) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Division; Municipal Hygiene Laboratory","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(147 – 2500) μS/cm"}],"search_en":"Water Electrical conductivity Conductometric method Laboratory Division; Municipal Hygiene Laboratory Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(147 – 2500) μS/cm"}],"search_zh":"水 电导率 电导法 实验室分部；公共卫生检验室 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水","lab_section_zh":"实验室分部；公共卫生检验室"},{"_id":"6a7d7c010636ba417e41c165","lab_id":"69ad52a3de79e566650fb3a6","country":"PL","accr_number":"AB 722","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie jonu amonowego","parameters":[{"name":"Zakres","range":"(0,13 – 3,87) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie jonu amonowego\nZakres (0,13 – 3,87) mg/l\nMetoda spektrofotometryczna","reference":"PN-C-04576-4:1994","norm_bases":["PN-C-04576-4:1994"],"lab_section":"Oddział Laboratoryjny; Pracownia Higieny Komunalnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie jonu amonowego\nZakres (0,13 – 3,87) mg/l\nMetoda spektrofotometryczna PN-C-04576-4:1994 Woda Stezenie jonu amonowego\nZakres (0,13 – 3,87) mg/l\nMetoda spektrofotometryczna PN-C-04576-4:1994","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Division; Municipal Hygiene Laboratory","methodology_en":"Ammonium ion concentration","parameters_en":[{"name":"Range","range":"(0,13 – 3,87) mg/l"}],"search_en":"Water Ammonium ion concentration Spectrophotometric method Laboratory Division; Municipal Hygiene Laboratory Range PN-C-04576-4:1994","technique_en":"Spectrophotometric method","test_object_en":"Water","methodology_zh":"铵离子浓度","parameters_zh":[{"name":"范围","range":"(0,13 – 3,87) mg/l"}],"search_zh":"水 铵离子浓度 分光光度法 实验室分部；公共卫生检验室 范围 PN-C-04576-4:1994","technique_zh":"分光光度法","test_object_zh":"水","lab_section_zh":"实验室分部；公共卫生检验室"},{"_id":"6a7d7c010636ba417e41c166","lab_id":"69ad52a3de79e566650fb3a6","country":"PL","accr_number":"AB 722","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie azotanów","parameters":[{"name":"Zakres","range":"(0,9 – 220) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotanów\nZakres (0,9 – 220) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576.08","norm_bases":["PN-82/C-04576.08"],"lab_section":"Oddział Laboratoryjny; Pracownia Higieny Komunalnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie azotanów\nZakres (0,9 – 220) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08 Woda Stezenie azotanow\nZakres (0,9 – 220) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Division; Municipal Hygiene Laboratory","methodology_en":"Nitrate concentration","parameters_en":[{"name":"Range","range":"(0,9 – 220) mg/l"}],"search_en":"Water Nitrate concentration Spectrophotometric method Laboratory Division; Municipal Hygiene Laboratory Range PN-82/C-04576.08","technique_en":"Spectrophotometric method","test_object_en":"Water","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,9 – 220) mg/l"}],"search_zh":"水 硝酸盐浓度 分光光度法 实验室分部；公共卫生检验室 范围 PN-82/C-04576.08","technique_zh":"分光光度法","test_object_zh":"水","lab_section_zh":"实验室分部；公共卫生检验室"},{"_id":"6a7d7c010636ba417e41c167","lab_id":"69ad52a3de79e566650fb3a6","country":"PL","accr_number":"AB 722","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie azotynów","parameters":[{"name":"Zakres","range":"(0,066 – 0,66) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotynów\nZakres (0,066 – 0,66) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Oddział Laboratoryjny; Pracownia Higieny Komunalnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie azotynów\nZakres (0,066 – 0,66) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda Stezenie azotynow\nZakres (0,066 – 0,66) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Division; Municipal Hygiene Laboratory","methodology_en":"Nitrite concentration","parameters_en":[{"name":"Range","range":"(0,066 – 0,66) mg/l"}],"search_en":"Water Nitrite concentration Spectrophotometric method Laboratory Division; Municipal Hygiene Laboratory Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,066 – 0,66) mg/l"}],"search_zh":"水 亚硝酸盐浓度 分光光度法 实验室分部；公共卫生检验室 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水","lab_section_zh":"实验室分部；公共卫生检验室"},{"_id":"6a7d7c010636ba417e41c168","lab_id":"69ad52a3de79e566650fb3a6","country":"PL","accr_number":"AB 722","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie manganu","parameters":[{"name":"Zakres","range":"(0,040 – 1,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie manganu\nZakres (0,040 – 1,00) mg/l\nMetoda spektrofotometryczna","reference":"PN-92/C-04590.03","norm_bases":["PN-92/C-04590.03"],"lab_section":"Oddział Laboratoryjny; Pracownia Higieny Komunalnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie manganu\nZakres (0,040 – 1,00) mg/l\nMetoda spektrofotometryczna PN-92/C-04590.03 Woda Stezenie manganu\nZakres (0,040 – 1,00) mg/l\nMetoda spektrofotometryczna PN-92/C-04590.03","categories":["water"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Division; Municipal Hygiene Laboratory","methodology_en":"Manganese concentration","parameters_en":[{"name":"Range","range":"(0,040 – 1,00) mg/l"}],"search_en":"Water Manganese concentration Spectrophotometric method Laboratory Division; Municipal Hygiene Laboratory Range PN-92/C-04590.03","technique_en":"Spectrophotometric method","test_object_en":"Water","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(0,040 – 1,00) mg/l"}],"search_zh":"水 锰浓度 分光光度法 实验室分部；公共卫生检验室 范围 PN-92/C-04590.03","technique_zh":"分光光度法","test_object_zh":"水","lab_section_zh":"实验室分部；公共卫生检验室"},{"_id":"6a7d7c010636ba417e41c169","lab_id":"69ad52a3de79e566650fb3a6","country":"PL","accr_number":"AB 722","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie żelaza","parameters":[{"name":"Zakres","range":"(0,040 – 2,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza\nZakres (0,040 – 2,00) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001+Ap1:2016-06","norm_bases":["PN-ISO 6332:2001+Ap1:2016-06"],"lab_section":"Oddział Laboratoryjny; Pracownia Higieny Komunalnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie żelaza\nZakres (0,040 – 2,00) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06 Woda Stezenie zelaza\nZakres (0,040 – 2,00) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06","categories":["water"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Division; Municipal Hygiene Laboratory","methodology_en":"Iron concentration","parameters_en":[{"name":"Range","range":"(0,040 – 2,00) mg/l"}],"search_en":"Water Iron concentration Spectrophotometric method Laboratory Division; Municipal Hygiene Laboratory Range PN-ISO 6332:2001+Ap1:2016-06","technique_en":"Spectrophotometric method","test_object_en":"Water","methodology_zh":"铁浓度","parameters_zh":[{"name":"范围","range":"(0,040 – 2,00) mg/l"}],"search_zh":"水 铁浓度 分光光度法 实验室分部；公共卫生检验室 范围 PN-ISO 6332:2001+Ap1:2016-06","technique_zh":"分光光度法","test_object_zh":"水","lab_section_zh":"实验室分部；公共卫生检验室"},{"_id":"6a7d7c010636ba417e41c16a","lab_id":"69ad52a3de79e566650fb3a6","country":"PL","accr_number":"AB 722","accr_body":"PCA","test_object":"Woda","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,20 – 100) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,20 – 100) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":"Oddział Laboratoryjny; Pracownia Higieny Komunalnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Mętność\nZakres (0,20 – 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda Metnosc\nZakres (0,20 – 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Division; Municipal Hygiene Laboratory","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,20 – 100) NTU"}],"search_en":"Water Turbidity Nephelometric method Laboratory Division; Municipal Hygiene Laboratory Range PN-EN ISO 7027-1:2016-09","technique_en":"Nephelometric method","test_object_en":"Water","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,20 – 100) NTU"}],"search_zh":"水 浊度 浊度法（散射法） 实验室分部；公共卫生检验室 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"水","lab_section_zh":"实验室分部；公共卫生检验室"},{"_id":"6a7d7c010636ba417e41c16b","lab_id":"69ad52a3de79e566650fb3a6","country":"PL","accr_number":"AB 722","accr_body":"PCA","test_object":"Woda","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(5 – 70) mg/l Pt"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Barwa\nZakres (5 – 70) mg/l Pt\nMetoda wizualna","reference":"PN-EN ISO 7887:2012+Ap1:2015-06 metoda D","norm_bases":["PN-EN ISO 7887:2012+Ap1:2015-06 metoda D"],"lab_section":"Oddział Laboratoryjny; Pracownia Higieny Komunalnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Barwa\nZakres (5 – 70) mg/l Pt\nMetoda wizualna PN-EN ISO 7887:2012+Ap1:2015-06 metoda D Woda Barwa\nZakres (5 – 70) mg/l Pt\nMetoda wizualna PN-EN ISO 7887:2012+Ap1:2015-06 metoda D","categories":["water"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Division; Municipal Hygiene Laboratory","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"(5 – 70) mg/l Pt"}],"search_en":"Water Colour Visual method Laboratory Division; Municipal Hygiene Laboratory Range PN-EN ISO 7887:2012+Ap1:2015-06 metoda D","technique_en":"Visual method","test_object_en":"Water","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(5 – 70) mg/l Pt"}],"search_zh":"水 色度 目视法 实验室分部；公共卫生检验室 范围 PN-EN ISO 7887:2012+Ap1:2015-06 metoda D","technique_zh":"目视法","test_object_zh":"水","lab_section_zh":"实验室分部；公共卫生检验室"},{"_id":"6a7d7c010636ba417e41c16c","lab_id":"69ad52a3de79e566650fb3a6","country":"PL","accr_number":"AB 722","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba progowa zapachu TON","parameters":[{"name":"Zakres","range":"1"}],"technique":"Metoda uproszczona, parzysta, wybór niewymuszony","techniques":["Metoda uproszczona, parzysta, wybór niewymuszony"],"computed":[],"activity":"Liczba progowa zapachu TON\nZakres 1\nMetoda uproszczona, parzysta, wybór niewymuszony","reference":"PN-EN 1622:2006","norm_bases":["PN-EN 1622:2006"],"lab_section":"Oddział Laboratoryjny; Pracownia Higieny Komunalnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba progowa zapachu TON\nZakres 1\nMetoda uproszczona, parzysta, wybór niewymuszony PN-EN 1622:2006 Woda do spozycia przez ludzi Liczba progowa zapachu TON\nZakres 1\nMetoda uproszczona, parzysta, wybor niewymuszony PN-EN 1622:2006","categories":["water"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Division; Municipal Hygiene Laboratory","methodology_en":"Odour threshold number TON","parameters_en":[{"name":"Range","range":"1"}],"search_en":"Water intended for human consumption Odour threshold number TON Simplified method, paired, non-forced choice Laboratory Division; Municipal Hygiene Laboratory Range PN-EN 1622:2006","technique_en":"Simplified method, paired, non-forced choice","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"1"}],"search_zh":"生活饮用水 嗅阈值 TON 简化法，成对，非强制选择 实验室分部；公共卫生检验室 范围 PN-EN 1622:2006","test_object_zh":"生活饮用水","technique_zh":"简化法，成对，非强制选择","methodology_zh":"嗅阈值 TON","lab_section_zh":"实验室分部；公共卫生检验室"},{"_id":"6a7d7c010636ba417e41c16d","lab_id":"69ad52a3de79e566650fb3a6","country":"PL","accr_number":"AB 722","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba progowa smaku TFN","parameters":[{"name":"Zakres","range":"1"}],"technique":"Metoda uproszczona, parzysta, wybór niewymuszony","techniques":["Metoda uproszczona, parzysta, wybór niewymuszony"],"computed":[],"activity":"Liczba progowa smaku TFN\nZakres 1\nMetoda uproszczona, parzysta, wybór niewymuszony","reference":"PN-EN 1622:2006","norm_bases":["PN-EN 1622:2006"],"lab_section":"Oddział Laboratoryjny; Pracownia Higieny Komunalnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba progowa smaku TFN\nZakres 1\nMetoda uproszczona, parzysta, wybór niewymuszony PN-EN 1622:2006 Woda do spozycia przez ludzi Liczba progowa smaku TFN\nZakres 1\nMetoda uproszczona, parzysta, wybor niewymuszony PN-EN 1622:2006","categories":["water"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Division; Municipal Hygiene Laboratory","methodology_en":"Taste threshold number TFN","parameters_en":[{"name":"Range","range":"1"}],"search_en":"Water intended for human consumption Taste threshold number TFN Simplified method, paired, non-forced choice Laboratory Division; Municipal Hygiene Laboratory Range PN-EN 1622:2006","technique_en":"Simplified method, paired, non-forced choice","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"1"}],"search_zh":"生活饮用水 味阈值 TFN 简化法，成对，非强制选择 实验室分部；公共卫生检验室 范围 PN-EN 1622:2006","test_object_zh":"生活饮用水","technique_zh":"简化法，成对，非强制选择","methodology_zh":"味阈值 TFN","lab_section_zh":"实验室分部；公共卫生检验室"},{"_id":"6a7d7c010636ba417e41c16e","lab_id":"69ad52a3de79e566650fb3a6","country":"PL","accr_number":"AB 722","accr_body":"PCA","test_object":"Środowisko pracy – hałas","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(30 – 135) dB"},{"name":"Szczytowy poziom dźwięku C"},{"name":"Zakres","range":"(45 – 137) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (30 – 135) dB\nSzczytowy poziom dźwięku C\nZakres (45 – 137) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 – punkt 10 i Strategię 3 – punkt 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 – punkt 10 i Strategię 3 – punkt 11"],"lab_section":"Oddział Laboratoryjny; Pracownia Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (30 – 135) dB\nSzczytowy poziom dźwięku C\nZakres (45 – 137) dB\nMetoda pomiarowa bezpośrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 – punkt 10 i Strategię 3 – punkt 11 Srodowisko pracy – halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A\nZakres:\nZakres (30 – 135) dB\nSzczytowy poziom dzwieku C\nZakres (45 – 137) dB\nMetoda pomiarowa bezposrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej Strategie 2 – punkt 10 i Strategie 3 – punkt 11","categories":["environment"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Division; Occupational Hygiene Laboratory","methodology_en":"A-weighted equivalent sound level Maximum A-weighted sound level","parameters_en":[{"name":"Range","range":"(30 – 135) dB"},{"name":"C-weighted peak sound pressure level"},{"name":"Range","range":"(45 – 137) dB"}],"search_en":"Workplace environment – noise A-weighted equivalent sound level Maximum A-weighted sound level Direct measurement method Laboratory Division; Occupational Hygiene Laboratory Range C-weighted peak sound pressure level Range PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 – punkt 10 i Strategię 3 – punkt 11","technique_en":"Direct measurement method","test_object_en":"Workplace environment – noise","methodology_zh":"A 计权等效声级 A 计权最大声级","parameters_zh":[{"name":"范围","range":"(30 – 135) dB"},{"name":"C 计权峰值声级"},{"name":"范围","range":"(45 – 137) dB"}],"search_zh":"工作场所环境 — 噪声 A 计权等效声级 A 计权最大声级 直接测量法 实验室分部；劳动卫生检验室 范围 C 计权峰值声级 范围 PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 – punkt 10 i Strategię 3 – punkt 11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 噪声","lab_section_zh":"实验室分部；劳动卫生检验室"},{"_id":"6a7d7c010636ba417e41c16f","lab_id":"69ad52a3de79e566650fb3a6","country":"PL","accr_number":"AB 722","accr_body":"PCA","test_object":"Środowisko pracy – hałas","methodology":"Poziom ekspozycji na hałas odniesiony do:","parameters":[{"name":"8-godz. dobowego wymiaru czasu pracy"},{"name":"przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 – punkt 10 i Strategię 3 – punkt 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 – punkt 10 i Strategię 3 – punkt 11"],"lab_section":"Oddział Laboratoryjny; Pracownia Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – hałas Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 – punkt 10 i Strategię 3 – punkt 11 Srodowisko pracy – halas Poziom ekspozycji na halas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzecietnego tygodniowego wymiaru czasu pracy (z obliczen) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej Strategie 2 – punkt 10 i Strategie 3 – punkt 11","categories":["environment"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Division; Occupational Hygiene Laboratory","methodology_en":"Noise exposure level referred to:","parameters_en":[{"name":"an 8-hour daily working time"},{"name":"the average weekly working time (calculated)"}],"search_en":"Workplace environment – noise Noise exposure level referred to: Laboratory Division; Occupational Hygiene Laboratory an 8-hour daily working time the average weekly working time (calculated) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 – punkt 10 i Strategię 3 – punkt 11","test_object_en":"Workplace environment – noise","methodology_zh":"噪声暴露级，参照：","parameters_zh":[{"name":"8 小时日工作时间"},{"name":"平均每周工作时间（计算值）"}],"search_zh":"工作场所环境 — 噪声 噪声暴露级，参照： 实验室分部；劳动卫生检验室 8 小时日工作时间 平均每周工作时间（计算值） PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 – punkt 10 i Strategię 3 – punkt 11","test_object_zh":"工作场所环境 — 噪声","lab_section_zh":"实验室分部；劳动卫生检验室"},{"_id":"6a7d7c010636ba417e41c170","lab_id":"69ad52a3de79e566650fb3a6","country":"PL","accr_number":"AB 722","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Pobieranie próbek w celu oceny narażenia zawodowego na:","parameters":[{"name":"pyły przemysłowe"},{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna"},{"name":"substancje nieorganiczne"},{"name":"frakcja respirabilna"}],"technique":"Metoda dozymetrii indywidualnej","techniques":["Metoda dozymetrii indywidualnej"],"computed":[],"activity":"Pobieranie próbek w celu oceny narażenia zawodowego na:\nZakres:\npyły przemysłowe\nfrakcja wdychalna\nfrakcja respirabilna\nsubstancje nieorganiczne\nfrakcja respirabilna\nMetoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002+Az1:2004"],"lab_section":"Oddział Laboratoryjny; Pracownia Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Pobieranie próbek w celu oceny narażenia zawodowego na:\nZakres:\npyły przemysłowe\nfrakcja wdychalna\nfrakcja respirabilna\nsubstancje nieorganiczne\nfrakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy – powietrze Pobieranie probek w celu oceny narazenia zawodowego na:\nZakres:\npyly przemyslowe\nfrakcja wdychalna\nfrakcja respirabilna\nsubstancje nieorganiczne\nfrakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002+Az1:2004","categories":["environment"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Division; Occupational Hygiene Laboratory","methodology_en":"Sampling for the assessment of occupational exposure to:","parameters_en":[{"name":"industrial dusts"},{"name":"inhalable fraction"},{"name":"respirable fraction"},{"name":"inorganic substances"},{"name":"respirable fraction"}],"search_en":"Workplace environment – air Sampling for the assessment of occupational exposure to: Personal dosimetry method Laboratory Division; Occupational Hygiene Laboratory industrial dusts inhalable fraction respirable fraction inorganic substances respirable fraction PN-Z-04008-7:2002+Az1:2004","technique_en":"Personal dosimetry method","test_object_en":"Workplace environment – air","parameters_zh":[{"name":"工业粉尘"},{"name":"可吸入组分"},{"name":"呼吸性组分"},{"name":"无机物质"},{"name":"呼吸性组分"}],"search_zh":"工作场所环境 — 空气 职业接触评估采样，针对： 个体剂量测定法 实验室分部；劳动卫生检验室 工业粉尘 可吸入组分 呼吸性组分 无机物质 呼吸性组分 PN-Z-04008-7:2002+Az1:2004","technique_zh":"个体剂量测定法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"职业接触评估采样，针对：","lab_section_zh":"实验室分部；劳动卫生检验室"},{"_id":"6a7d7c010636ba417e41c171","lab_id":"69ad52a3de79e566650fb3a6","country":"PL","accr_number":"AB 722","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Wskaźnik narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002+Az1:2004"],"lab_section":"Oddział Laboratoryjny; Pracownia Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Wskaźnik narażenia (z obliczeń) PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy – powietrze Wskaznik narazenia (z obliczen) PN-Z-04008-7:2002+Az1:2004","categories":["environment"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Division; Occupational Hygiene Laboratory","methodology_en":"Exposure index (calculated)","search_en":"Workplace environment – air Exposure index (calculated) Laboratory Division; Occupational Hygiene Laboratory PN-Z-04008-7:2002+Az1:2004","test_object_en":"Workplace environment – air","methodology_zh":"暴露指数（计算得出）","search_zh":"工作场所环境 — 空气 暴露指数（计算得出） 实验室分部；劳动卫生检验室 PN-Z-04008-7:2002+Az1:2004","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"实验室分部；劳动卫生检验室"},{"_id":"6a7d7c010636ba417e41c172","lab_id":"69ad52a3de79e566650fb3a6","country":"PL","accr_number":"AB 722","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna:","parameters":[{"name":"Pyły niesklasyfikowane ze względu na toksyczność"},{"name":"Pyły drewna"},{"name":"Pyły mąki"},{"name":"Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Zakres","range":"(0,3 – 17,0) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna:\nZakres:\nPyły niesklasyfikowane ze względu na toksyczność\nPyły drewna\nPyły mąki\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nZakres (0,3 – 17,0) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04507:2022-05","PN-Z-04507:2022-05/Ap1:2022-08"],"lab_section":"Oddział Laboratoryjny; Pracownia Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna:\nZakres:\nPyły niesklasyfikowane ze względu na toksyczność\nPyły drewna\nPyły mąki\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nZakres (0,3 – 17,0) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08 Srodowisko pracy – powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia - frakcja wdychalna:\nZakres:\nPyly niesklasyfikowane ze wzgledu na toksycznosc\nPyly drewna\nPyly maki\nPyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nZakres (0,3 – 17,0) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","categories":["environment"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Division; Occupational Hygiene Laboratory","methodology_en":"Concentration of harmful dust agents - inhalable fraction:","parameters_en":[{"name":"Dusts not classified according to toxicity"},{"name":"Wood dusts"},{"name":"Flour dusts"},{"name":"Organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"Range","range":"(0,3 – 17,0) mg/m3"}],"search_en":"Workplace environment – air Concentration of harmful dust agents - inhalable fraction: Gravimetric method Laboratory Division; Occupational Hygiene Laboratory Dusts not classified according to toxicity Wood dusts Flour dusts Organic dusts of animal and plant origin, excluding wood and flour dusts Range PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment – air","parameters_zh":[{"name":"未按毒性分类的粉尘"},{"name":"木粉尘"},{"name":"面粉粉尘"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"范围","range":"(0,3 – 17,0) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害粉尘因素浓度 — 可吸入组分： 重量法 实验室分部；劳动卫生检验室 未按毒性分类的粉尘 木粉尘 面粉粉尘 动植物来源有机粉尘，木粉和面粉除外 范围 PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"有害粉尘因素浓度 — 可吸入组分：","lab_section_zh":"实验室分部；劳动卫生检验室"},{"_id":"6a7d7c010636ba417e41c173","lab_id":"69ad52a3de79e566650fb3a6","country":"PL","accr_number":"AB 722","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja respirabilna:","parameters":[{"name":"Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Zakres","range":"(0,3 – 7,8) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja respirabilna:\nZakres:\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nZakres (0,3 – 7,8) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04508:2022-05","PN-Z-04508:2022-05/Ap1:2022-08"],"lab_section":"Oddział Laboratoryjny; Pracownia Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja respirabilna:\nZakres:\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nZakres (0,3 – 7,8) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08 Srodowisko pracy – powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia - frakcja respirabilna:\nZakres:\nPyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nZakres (0,3 – 7,8) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","categories":["environment"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Division; Occupational Hygiene Laboratory","methodology_en":"Concentration of harmful dust agents - respirable fraction:","parameters_en":[{"name":"Organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"Range","range":"(0,3 – 7,8) mg/m3"}],"search_en":"Workplace environment – air Concentration of harmful dust agents - respirable fraction: Gravimetric method Laboratory Division; Occupational Hygiene Laboratory Organic dusts of animal and plant origin, excluding wood and flour dusts Range PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment – air","parameters_zh":[{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"范围","range":"(0,3 – 7,8) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害健康的粉尘因子浓度 － 呼吸性粉尘： 重量法 实验室分部；劳动卫生检验室 动植物来源有机粉尘，木粉和面粉除外 范围 PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"有害健康的粉尘因子浓度 － 呼吸性粉尘：","lab_section_zh":"实验室分部；劳动卫生检验室"},{"_id":"6a7d7c010636ba417e41c174","lab_id":"69ad52a3de79e566650fb3a6","country":"PL","accr_number":"AB 722","accr_body":"PCA","test_object":"Kał, wymaz z odbytu","methodology":"Obecność pałeczek jelitowych z rodzaju, Salmonella, Shigella","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność pałeczek jelitowych z rodzaju, Salmonella, Shigella\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PB/OL/03 wydanie 4 z dnia 28.06.2017 r.","norm_bases":["PB/OL/03 wydanie 4 z dnia 28.06.2017 r."],"lab_section":"Oddział Laboratoryjny; Pracownia Diagnostyki Mikrobiologicznej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kał, wymaz z odbytu Obecność pałeczek jelitowych z rodzaju, Salmonella, Shigella\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB/OL/03 wydanie 4 z dnia 28.06.2017 r. Kal, wymaz z odbytu Obecnosc paleczek jelitowych z rodzaju, Salmonella, Shigella\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB/OL/03 wydanie 4 z dnia 28.06.2017 r.","categories":["microbiology"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Division; Microbiological Diagnostics Laboratory","methodology_en":"Presence of enteric rods of the genera, Salmonella, Shigella","search_en":"Faeces, rectal swab Presence of enteric rods of the genera, Salmonella, Shigella Culture method with biochemical and serological confirmation Laboratory Division; Microbiological Diagnostics Laboratory PB/OL/03 wydanie 4 z dnia 28.06.2017 r.","technique_en":"Culture method with biochemical and serological confirmation","test_object_en":"Faeces, rectal swab","search_zh":"粪便、肛拭子 培养法结合生化与血清学确认 PB/OL/03 wydanie 4 z dnia 28.06.2017 r.","technique_zh":"培养法结合生化与血清学确认","test_object_zh":"粪便、肛拭子"}],"has_pdf":true}