{"lab":{"_id":"69ad52a3de79e566650fb38a","accr_number":"AB 697","country":"PL","accr_body":"PCA","address":"WODOCIĄGÓW I KANALIZACJI Sp. z o.o. W GDYNI, ul. Witomińska 29; 81-311 Gdynia, DZIAŁ LABORATORIUM WODY I ŚCIEKÓW, ul. Dąbrowskiego 58, 84-230 Rumia","categories":["water","microbiology"],"city":"Gdynia","imported_at":"2026-03-08T10:42:43.265Z","methods_count":74,"name":"PRZEDSIĘBIORSTWO","parse_status":"parsed","parse_version":3,"pdf_files":["AB_697.pdf"],"scope_summary":"","search_text":"przedsiębiorstwo wodociągów i kanalizacji sp. z o.o. w gdyni, ul. witomińska 29; 81-311 gdynia, dział laboratorium wody i ścieków, ul. dąbrowskiego 58, 84-230 rumia other water pharma electronics materials microbiology automotive environment","status":"active","updated_at":"2026-03-08T14:51:35.992Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:35.992Z","location":{"type":"Point","coordinates":[18.5305,54.5189]},"email_confidence":"high","email_mx":true,"email_source":"https://www.pca.gov.pl/akredytowane-podmioty/akredytacje-aktywne/laboratoria-badawcze/AB%20697,podmiot.html","fields_of_testing":[{"codes":"C/28/P; C/29/P","pl":"Badania chemiczne i pobieranie próbek wody, wody do spożycia przez ludzi","en":"Chemical tests and sampling of water, drinking water"},{"codes":"C/30/P","pl":"Badania chemiczne i pobieranie próbek ścieków","en":"Chemical tests and sampling of sewage"},{"codes":"C/32","pl":"Badania chemiczne osadów ściekowych, odpadów","en":"Chemical tests of sediments, waste"},{"codes":"N/32","pl":"Badania właściwości fizycznych osadów ściekowych","en":"Tests of physical properties of sediments"},{"codes":"N/28/P; N/29/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, wody do spożycia przez ludzi","en":"Tests of physical properties and sampling of water, drinking water"},{"codes":"N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek ścieków","en":"Tests of physical properties and sampling of sewage"},{"codes":"K/28/P, K/29/P","pl":"Badania mikrobiologiczne i pobieranie próbek wody, wody do spożycia przez ludzi","en":"Microbiological tests and sampling of water, drinking water"},{"codes":"Q/28/P, Q/29/P","pl":"Badania sensoryczne i pobieranie próbek wody, wody do spożycia przez ludzi","en":"Sensory tests and sampling of water, drinking water"}],"parse_date":"2026-07-20T07:09:48.244Z","parse_source":"script-pdfplumber","map_coord":[54.510517,18.526369],"map_geo":"nominatim-street","has_en":true,"category_counts":{"water":73,"microbiology":5,"materials":4,"environment":1},"category_scores":{"water":64.2,"microbiology":0.3,"materials":0.19,"environment":0.01},"has_zh":true},"methods":[{"_id":"6a5dc9bcf1c10c8ce825e1fc","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"4,0 - 10,0"}],"parameters_en":[{"name":"Range","range":"4,0 - 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 4,0 - 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi pH\nZakres 4,0 - 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, Woda do spozycia przez ludzi pH\nZakres 4,0 - 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 - 10,0"}],"search_zh":"水、生活饮用水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9bcf1c10c8ce825e1fd","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Przewodność elektryczna właściwa","methodology_en":"Electrical conductivity","parameters":[{"name":"Zakres","range":"(200 - 2500) μS/cm"}],"parameters_en":[{"name":"Range","range":"(200 - 2500) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"technique_en":"Conductometric method","computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa\nZakres (200 - 2500) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Przewodność elektryczna właściwa\nZakres (200 - 2500) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, Woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa\nZakres (200 - 2500) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Electrical conductivity Conductometric method Range PN-EN 27888:1999","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(200 - 2500) μS/cm"}],"search_zh":"水、生活饮用水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9bcf1c10c8ce825e1fe","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Stężenie żelaza ogólnego","methodology_en":"Total iron concentration","parameters":[{"name":"Zakres","range":"(30 - 35000) μg/l"}],"parameters_en":[{"name":"Range","range":"(30 - 35000) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie żelaza ogólnego\nZakres (30 - 35000) μg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001 + Ap1:2016-06","norm_bases":["PN-ISO 6332:2001 + Ap1:2016-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie żelaza ogólnego\nZakres (30 - 35000) μg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001 + Ap1:2016-06 Woda, Woda do spozycia przez ludzi Stezenie zelaza ogolnego\nZakres (30 - 35000) μg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001 + Ap1:2016-06","categories":["water"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Total iron concentration Spectrophotometric method Range PN-ISO 6332:2001 + Ap1:2016-06","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(30 - 35000) μg/l"}],"search_zh":"水、生活饮用水 总铁浓度 分光光度法 范围 PN-ISO 6332:2001 + Ap1:2016-06","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9bcf1c10c8ce825e1ff","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)","methodology_en":"Total content of calcium and magnesium (total hardness)","parameters":[{"name":"Zakres","range":"(10 - 2000) mg/l CaCO3"}],"parameters_en":[{"name":"Range","range":"(10 - 2000) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (10 - 2000) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (10 - 2000) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999 Woda, Woda do spozycia przez ludzi Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna)\nZakres (10 - 2000) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Total content of calcium and magnesium (total hardness) Titrimetric method Range PN-ISO 6059:1999","methodology_zh":"钙与镁总量（总硬度）","parameters_zh":[{"name":"范围","range":"(10 - 2000) mg/l CaCO3"}],"search_zh":"水、生活饮用水 钙与镁总量（总硬度） 滴定法 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9bcf1c10c8ce825e200","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Zasadowość ogólna","methodology_en":"Total alkalinity","parameters":[{"name":"Zakres","range":"(0,50 - 20,0) mmol/l"}],"parameters_en":[{"name":"Range","range":"(0,50 - 20,0) mmol/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Zasadowość ogólna\nZakres (0,50 - 20,0) mmol/l\nMetoda miareczkowa","reference":"PN-EN ISO 9963-1:2001 p.8.2 + Ap1:2004","norm_bases":["PN-EN ISO 9963-1:2001 p.8.2 + Ap1:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Zasadowość ogólna\nZakres (0,50 - 20,0) mmol/l\nMetoda miareczkowa PN-EN ISO 9963-1:2001 p.8.2 + Ap1:2004 Woda, Woda do spozycia przez ludzi Zasadowosc ogolna\nZakres (0,50 - 20,0) mmol/l\nMetoda miareczkowa PN-EN ISO 9963-1:2001 p.8.2 + Ap1:2004","categories":["water"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Total alkalinity Titrimetric method Range PN-EN ISO 9963-1:2001 p.8.2 + Ap1:2004","parameters_zh":[{"name":"范围","range":"(0,50 - 20,0) mmol/l"}],"search_zh":"水、生活饮用水 总碱度 滴定法 范围 PN-EN ISO 9963-1:2001 p.8.2 + Ap1:2004","technique_zh":"滴定法","test_object_zh":"水、生活饮用水","methodology_zh":"总碱度"},{"_id":"6a5dc9bcf1c10c8ce825e201","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Stężenie wapnia","methodology_en":"Calcium concentration","parameters":[{"name":"Zakres","range":"(7 - 500) mg/l"}],"parameters_en":[{"name":"Range","range":"(7 - 500) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie wapnia\nZakres (7 - 500) mg/l\nMetoda miareczkowa","reference":"PN-ISO 6058:1999","norm_bases":["PN-ISO 6058:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie wapnia\nZakres (7 - 500) mg/l\nMetoda miareczkowa PN-ISO 6058:1999 Woda, Woda do spozycia przez ludzi Stezenie wapnia\nZakres (7 - 500) mg/l\nMetoda miareczkowa PN-ISO 6058:1999","categories":["water"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Calcium concentration Titrimetric method Range PN-ISO 6058:1999","parameters_zh":[{"name":"范围","range":"(7 - 500) mg/l"}],"search_zh":"水、生活饮用水 钙浓度 滴定法 范围 PN-ISO 6058:1999","technique_zh":"滴定法","test_object_zh":"水、生活饮用水","methodology_zh":"钙浓度"},{"_id":"6a5dc9bcf1c10c8ce825e202","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Stężenie magnezu (z obliczeń)","methodology_en":"Magnesium concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie magnezu (z obliczeń)","reference":"PN-99/C-04554-4 Załącznik A","norm_bases":["PN-99/C-04554-4 Załącznik A"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie magnezu (z obliczeń) PN-99/C-04554-4 Załącznik A Woda, Woda do spozycia przez ludzi Stezenie magnezu (z obliczen) PN-99/C-04554-4 Zalacznik A","categories":["water"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Magnesium concentration (calculated) PN-99/C-04554-4 Załącznik A","search_zh":"水、生活饮用水 镁浓度（计算值） PN-99/C-04554-4 Załącznik A","test_object_zh":"水、生活饮用水","methodology_zh":"镁浓度（计算值）"},{"_id":"6a5dc9bcf1c10c8ce825e203","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Stężenie manganu","methodology_en":"Manganese concentration","parameters":[{"name":"Zakres","range":"(10 - 10000) μg/l"}],"parameters_en":[{"name":"Range","range":"(10 - 10000) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie manganu\nZakres (10 - 10000) μg/l\nMetoda spektrofotometryczna","reference":"TL-PB-15 wydanie 1 z dnia 25.09.2020 r. | na podstawie testu odczynnikowego Macherey-Nagel nr 1-60","norm_bases":["TL-PB-15 wydanie 1 z dnia 25.09.2020 r.","na podstawie testu odczynnikowego Macherey-Nagel nr 1-60"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie manganu\nZakres (10 - 10000) μg/l\nMetoda spektrofotometryczna TL-PB-15 wydanie 1 z dnia 25.09.2020 r. | na podstawie testu odczynnikowego Macherey-Nagel nr 1-60 Woda, Woda do spozycia przez ludzi Stezenie manganu\nZakres (10 - 10000) μg/l\nMetoda spektrofotometryczna TL-PB-15 wydanie 1 z dnia 25.09.2020 r. | na podstawie testu odczynnikowego Macherey-Nagel nr 1-60","categories":["water"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Manganese concentration Spectrophotometric method Range TL-PB-15 wydanie 1 z dnia 25.09.2020 r. | na podstawie testu odczynnikowego Macherey-Nagel nr 1-60","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(10 - 10000) μg/l"}],"search_zh":"水、生活饮用水 锰浓度 分光光度法 范围 TL-PB-15 wydanie 1 z dnia 25.09.2020 r. | na podstawie testu odczynnikowego Macherey-Nagel nr 1-60","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9bcf1c10c8ce825e204","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Stężenie azotynów","methodology_en":"Nitrite concentration","parameters":[{"name":"Zakres","range":"(0,008 - 1,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,008 - 1,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotynów\nZakres (0,008 - 1,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie azotynów\nZakres (0,008 - 1,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, Woda do spozycia przez ludzi Stezenie azotynow\nZakres (0,008 - 1,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Nitrite concentration Spectrophotometric method Range PN-EN 26777:1999","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,008 - 1,0) mg/l"}],"search_zh":"水、生活饮用水 亚硝酸盐浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9bcf1c10c8ce825e205","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Stężenie azotanów","methodology_en":"Nitrate concentration","parameters":[{"name":"Zakres","range":"(0,25 - 80) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,25 - 80) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotanów\nZakres (0,25 - 80) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie azotanów\nZakres (0,25 - 80) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08 Woda, Woda do spozycia przez ludzi Stezenie azotanow\nZakres (0,25 - 80) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Nitrate concentration Spectrophotometric method Range PN-82/C-04576/08","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,25 - 80) mg/l"}],"search_zh":"水、生活饮用水 硝酸盐浓度 分光光度法 范围 PN-82/C-04576/08","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9bcf1c10c8ce825e206","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Stężenie chlorków","methodology_en":"Chloride concentration","parameters":[{"name":"Zakres","range":"(3,00 - 400) mg/l"}],"parameters_en":[{"name":"Range","range":"(3,00 - 400) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie chlorków\nZakres (3,00 - 400) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie chlorków\nZakres (3,00 - 400) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda, Woda do spozycia przez ludzi Stezenie chlorkow\nZakres (3,00 - 400) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Chloride concentration Titrimetric method Range PN-ISO 9297:1994","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(3,00 - 400) mg/l"}],"search_zh":"水、生活饮用水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9bcf1c10c8ce825e207","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Stężenie żelaza dwuwartościowego","methodology_en":"Divalent iron concentration","parameters":[{"name":"Zakres","range":"(30 - 20000) μg/l"}],"parameters_en":[{"name":"Range","range":"(30 - 20000) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie żelaza dwuwartościowego\nZakres (30 - 20000) μg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001 p.7.3 + Ap1:2016-06","norm_bases":["PN-ISO 6332:2001 p.7.3 + Ap1:2016-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie żelaza dwuwartościowego\nZakres (30 - 20000) μg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001 p.7.3 + Ap1:2016-06 Woda, Woda do spozycia przez ludzi Stezenie zelaza dwuwartosciowego\nZakres (30 - 20000) μg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001 p.7.3 + Ap1:2016-06","categories":["water"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Divalent iron concentration Spectrophotometric method Range PN-ISO 6332:2001 p.7.3 + Ap1:2016-06","parameters_zh":[{"name":"范围","range":"(30 - 20000) μg/l"}],"search_zh":"水、生活饮用水 分光光度法 范围 PN-ISO 6332:2001 p.7.3 + Ap1:2016-06","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9bcf1c10c8ce825e208","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Stężenie jonu amonu","methodology_en":"Ammonium ion concentration","parameters":[{"name":"Zakres","range":"(0,05 - 2,00) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,05 - 2,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie jonu amonu\nZakres (0,05 - 2,00) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie jonu amonu\nZakres (0,05 - 2,00) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, Woda do spozycia przez ludzi Stezenie jonu amonu\nZakres (0,05 - 2,00) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Ammonium ion concentration Spectrophotometric method Range PN-ISO 7150-1:2002","parameters_zh":[{"name":"范围","range":"(0,05 - 2,00) mg/l"}],"search_zh":"水、生活饮用水 铵离子浓度 分光光度法 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","methodology_zh":"铵离子浓度"},{"_id":"6a5dc9bcf1c10c8ce825e209","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Stężenie cyjanków ogólnych","methodology_en":"Total cyanide concentration","parameters":[{"name":"Zakres","range":"(0,002 - 0,060) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,002 - 0,060) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie cyjanków ogólnych\nZakres (0,002 - 0,060) mg/l\nMetoda spektrofotometryczna","reference":"TL-PB-10 wydanie 1 z dnia 25.09.2020 r. | na podstawie testu odczynnikowego Merck nr 1.09701.0001","norm_bases":["TL-PB-10 wydanie 1 z dnia 25.09.2020 r.","na podstawie testu odczynnikowego Merck nr 1.09701.0001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie cyjanków ogólnych\nZakres (0,002 - 0,060) mg/l\nMetoda spektrofotometryczna TL-PB-10 wydanie 1 z dnia 25.09.2020 r. | na podstawie testu odczynnikowego Merck nr 1.09701.0001 Woda, Woda do spozycia przez ludzi Stezenie cyjankow ogolnych\nZakres (0,002 - 0,060) mg/l\nMetoda spektrofotometryczna TL-PB-10 wydanie 1 z dnia 25.09.2020 r. | na podstawie testu odczynnikowego Merck nr 1.09701.0001","categories":["water"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Total cyanide concentration Spectrophotometric method Range TL-PB-10 wydanie 1 z dnia 25.09.2020 r. | na podstawie testu odczynnikowego Merck nr 1.09701.0001","parameters_zh":[{"name":"范围","range":"(0,002 - 0,060) mg/l"}],"search_zh":"水、生活饮用水 总氰化物浓度 分光光度法 范围 TL-PB-10 wydanie 1 z dnia 25.09.2020 r. | na podstawie testu odczynnikowego Merck nr 1.09701.0001","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","methodology_zh":"总氰化物浓度"},{"_id":"6a5dc9bcf1c10c8ce825e20a","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Sucha pozostałość","methodology_en":"Dry residue","parameters":[{"name":"Zakres","range":"(100 - 1800) mg/l"}],"parameters_en":[{"name":"Range","range":"(100 - 1800) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Sucha pozostałość\nZakres (100 - 1800) mg/l\nMetoda wagowa","reference":"TL-PB-24 wydanie 1 z dnia 25.09.2020 r.","norm_bases":["TL-PB-24 wydanie 1 z dnia 25.09.2020 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Sucha pozostałość\nZakres (100 - 1800) mg/l\nMetoda wagowa TL-PB-24 wydanie 1 z dnia 25.09.2020 r. Woda, Woda do spozycia przez ludzi Sucha pozostalosc\nZakres (100 - 1800) mg/l\nMetoda wagowa TL-PB-24 wydanie 1 z dnia 25.09.2020 r.","categories":["water"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Dry residue Gravimetric method Range TL-PB-24 wydanie 1 z dnia 25.09.2020 r.","parameters_zh":[{"name":"范围","range":"(100 - 1800) mg/l"}],"search_zh":"水、生活饮用水 干残渣 重量法 范围 TL-PB-24 wydanie 1 z dnia 25.09.2020 r.","technique_zh":"重量法","test_object_zh":"水、生活饮用水","methodology_zh":"干残渣"},{"_id":"6a5dc9bcf1c10c8ce825e20b","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Mętność","methodology_en":"Turbidity","parameters":[{"name":"Zakres","range":"(0,30 - 100) NTU"}],"parameters_en":[{"name":"Range","range":"(0,30 - 100) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"technique_en":"Nephelometric method","computed":[],"computed_en":[],"activity":"Mętność\nZakres (0,30 - 100) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Mętność\nZakres (0,30 - 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda, Woda do spozycia przez ludzi Metnosc\nZakres (0,30 - 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,30 - 100) NTU"}],"search_zh":"水、生活饮用水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9bcf1c10c8ce825e20c","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Stężenie lotnych związków organicznych","methodology_en":"Concentration of volatile organic compounds","parameters":[{"name":"benzen","range":"(0,10 - 100) μg/l"},{"name":"toluen","range":"(0,50 - 100) μg/l"},{"name":"etylobenzen","range":"(0,50 - 100) μg/l"},{"name":"o-ksylen","range":"(0,50 - 100) μg/l"},{"name":"m+p-ksylen","range":"(1,0 - 100) μg/l"},{"name":"chloroform","range":"(0,50 - 100) μg/l"},{"name":"bromodichlorometan","range":"(0,50 - 100) μg/l"},{"name":"dibromochlorometan","range":"(0,50 - 100) μg/l"},{"name":"bromoform","range":"(0,50 - 100) μg/l"},{"name":"tetrachlorometan","range":"(0,50 - 100) μg/l"},{"name":"Zakres","range":"1,2-dichloroetan (0,50 - 100) μg/l"},{"name":"trichloroeten","range":"(0,50 - 100) μg/l"},{"name":"tetrachloroeten","range":"(0,50 - 100) μg/l"},{"name":"chlorek winylu","range":"(0,10 - 100) μg/l"}],"parameters_en":[{"name":"benzene","range":"(0,10 - 100) μg/l"},{"name":"toluene","range":"(0,50 - 100) μg/l"},{"name":"ethylbenzene","range":"(0,50 - 100) μg/l"},{"name":"o-xylene","range":"(0,50 - 100) μg/l"},{"name":"m+p-xylene","range":"(1,0 - 100) μg/l"},{"name":"chloroform","range":"(0,50 - 100) μg/l"},{"name":"bromodichloromethane","range":"(0,50 - 100) μg/l"},{"name":"dibromochloromethane","range":"(0,50 - 100) μg/l"},{"name":"bromoform","range":"(0,50 - 100) μg/l"},{"name":"tetrachloromethane","range":"(0,50 - 100) μg/l"},{"name":"Range","range":"1,2-dichloroetan (0,50 - 100) μg/l"},{"name":"trichloroethene","range":"(0,50 - 100) μg/l"},{"name":"tetrachloroethene","range":"(0,50 - 100) μg/l"},{"name":"vinyl chloride","range":"(0,10 - 100) μg/l"}],"technique":"Metoda chromatografii gazowej z techniką wypłukiwania i wyłapywania (Purge&Trap) i detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z techniką wypłukiwania i wyłapywania (Purge&Trap) i detekcją spektrometrią mas (GC-MS)"],"technique_en":"Gas chromatography with purge and trap technique (Purge&Trap) and mass spectrometry detection (GC-MS)","computed":[],"computed_en":[],"activity":"Stężenie lotnych związków organicznych\nZakres:\nbenzen (0,10 - 100) μg/l\ntoluen (0,50 - 100) μg/l\netylobenzen (0,50 - 100) μg/l\no-ksylen (0,50 - 100) μg/l\nm+p-ksylen (1,0 - 100) μg/l\nchloroform (0,50 - 100) μg/l\nbromodichlorometan (0,50 - 100) μg/l\ndibromochlorometan (0,50 - 100) μg/l\nbromoform (0,50 - 100) μg/l\ntetrachlorometan (0,50 - 100) μg/l\nZakres 1,2-dichloroetan (0,50 - 100) μg/l\ntrichloroeten (0,50 - 100) μg/l\ntetrachloroeten (0,50 - 100) μg/l\nchlorek winylu (0,10 - 100) μg/l\nMetoda chromatografii gazowej z techniką wypłukiwania i wyłapywania (Purge&Trap) i detekcją spektrometrią mas (GC-MS)","reference":"PN-EN ISO 15680:2008","norm_bases":["PN-EN ISO 15680:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie lotnych związków organicznych\nZakres:\nbenzen (0,10 - 100) μg/l\ntoluen (0,50 - 100) μg/l\netylobenzen (0,50 - 100) μg/l\no-ksylen (0,50 - 100) μg/l\nm+p-ksylen (1,0 - 100) μg/l\nchloroform (0,50 - 100) μg/l\nbromodichlorometan (0,50 - 100) μg/l\ndibromochlorometan (0,50 - 100) μg/l\nbromoform (0,50 - 100) μg/l\ntetrachlorometan (0,50 - 100) μg/l\nZakres 1,2-dichloroetan (0,50 - 100) μg/l\ntrichloroeten (0,50 - 100) μg/l\ntetrachloroeten (0,50 - 100) μg/l\nchlorek winylu (0,10 - 100) μg/l\nMetoda chromatografii gazowej z techniką wypłukiwania i wyłapywania (Purge&Trap) i detekcją spektrometrią mas (GC-MS) PN-EN ISO 15680:2008 Woda, Woda do spozycia przez ludzi Stezenie lotnych zwiazkow organicznych\nZakres:\nbenzen (0,10 - 100) μg/l\ntoluen (0,50 - 100) μg/l\netylobenzen (0,50 - 100) μg/l\no-ksylen (0,50 - 100) μg/l\nm+p-ksylen (1,0 - 100) μg/l\nchloroform (0,50 - 100) μg/l\nbromodichlorometan (0,50 - 100) μg/l\ndibromochlorometan (0,50 - 100) μg/l\nbromoform (0,50 - 100) μg/l\ntetrachlorometan (0,50 - 100) μg/l\nZakres 1,2-dichloroetan (0,50 - 100) μg/l\ntrichloroeten (0,50 - 100) μg/l\ntetrachloroeten (0,50 - 100) μg/l\nchlorek winylu (0,10 - 100) μg/l\nMetoda chromatografii gazowej z technika wyplukiwania i wylapywania (Purge&Trap) i detekcja spektrometria mas (GC-MS) PN-EN ISO 15680:2008","categories":["water"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Concentration of volatile organic compounds Gas chromatography with purge and trap technique (Purge&Trap) and mass spectrometry detection (GC-MS) benzene toluene ethylbenzene o-xylene m+p-xylene chloroform bromodichloromethane dibromochloromethane bromoform tetrachloromethane Range trichloroethene tetrachloroethene vinyl chloride PN-EN ISO 15680:2008","parameters_zh":[{"name":"苯","range":"(0,10 - 100) μg/l"},{"name":"甲苯","range":"(0,50 - 100) μg/l"},{"name":"乙苯","range":"(0,50 - 100) μg/l"},{"name":"邻二甲苯","range":"(0,50 - 100) μg/l"},{"name":"间+对二甲苯","range":"(1,0 - 100) μg/l"},{"name":"三氯甲烷","range":"(0,50 - 100) μg/l"},{"name":"一溴二氯甲烷","range":"(0,50 - 100) μg/l"},{"name":"二溴一氯甲烷","range":"(0,50 - 100) μg/l"},{"name":"三溴甲烷","range":"(0,50 - 100) μg/l"},{"name":"四氯化碳","range":"(0,50 - 100) μg/l"},{"name":"范围","range":"1,2-dichloroetan (0,50 - 100) μg/l"},{"name":"三氯乙烯","range":"(0,50 - 100) μg/l"},{"name":"四氯乙烯","range":"(0,50 - 100) μg/l"},{"name":"氯乙烯","range":"(0,10 - 100) μg/l"}],"search_zh":"水、生活饮用水 挥发性有机物浓度 苯 甲苯 乙苯 邻二甲苯 间+对二甲苯 三氯甲烷 一溴二氯甲烷 二溴一氯甲烷 三溴甲烷 四氯化碳 范围 三氯乙烯 四氯乙烯 氯乙烯 PN-EN ISO 15680:2008","test_object_zh":"水、生活饮用水","methodology_zh":"挥发性有机物浓度"},{"_id":"6a5dc9bcf1c10c8ce825e20d","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Suma THM (z obliczeń)","methodology_en":"Sum of THM (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Suma THM (z obliczeń)","reference":"PN-EN ISO 15680:2008","norm_bases":["PN-EN ISO 15680:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Suma THM (z obliczeń) PN-EN ISO 15680:2008 Woda, Woda do spozycia przez ludzi Suma THM (z obliczen) PN-EN ISO 15680:2008","categories":["water"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Sum of THM (calculated) PN-EN ISO 15680:2008","search_zh":"水、生活饮用水 三卤甲烷总量（由计算得出） PN-EN ISO 15680:2008","test_object_zh":"水、生活饮用水","methodology_zh":"三卤甲烷总量（由计算得出）"},{"_id":"6a5dc9bcf1c10c8ce825e20e","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Suma trichloroetenu i tetrachloroetenu (z obliczeń)","methodology_en":"Sum of trichloroethene and tetrachloroethene (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Suma trichloroetenu i tetrachloroetenu (z obliczeń)","reference":"PN-EN ISO 15680:2008","norm_bases":["PN-EN ISO 15680:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Suma trichloroetenu i tetrachloroetenu (z obliczeń) PN-EN ISO 15680:2008 Woda, Woda do spozycia przez ludzi Suma trichloroetenu i tetrachloroetenu (z obliczen) PN-EN ISO 15680:2008","categories":["water"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Sum of trichloroethene and tetrachloroethene (calculated) PN-EN ISO 15680:2008","search_zh":"水、生活饮用水 三氯乙烯与四氯乙烯总量（由计算得出） PN-EN ISO 15680:2008","test_object_zh":"水、生活饮用水","methodology_zh":"三氯乙烯与四氯乙烯总量（由计算得出）"},{"_id":"6a5dc9bcf1c10c8ce825e20f","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Suma BTX (z obliczeń)","methodology_en":"Sum of BTX (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Suma BTX (z obliczeń)","reference":"PN-EN ISO 15680:2008","norm_bases":["PN-EN ISO 15680:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Suma BTX (z obliczeń) PN-EN ISO 15680:2008 Woda, Woda do spozycia przez ludzi Suma BTX (z obliczen) PN-EN ISO 15680:2008","categories":["water"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Sum of BTX (calculated) PN-EN ISO 15680:2008","search_zh":"水、生活饮用水 BTX 总量（由计算得出） PN-EN ISO 15680:2008","test_object_zh":"水、生活饮用水","methodology_zh":"BTX 总量（由计算得出）"},{"_id":"6a5dc9bcf1c10c8ce825e210","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Suma BTEX (z obliczeń)","methodology_en":"Sum of BTEX (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Suma BTEX (z obliczeń)","reference":"PN-EN ISO 15680:2008","norm_bases":["PN-EN ISO 15680:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Suma BTEX (z obliczeń) PN-EN ISO 15680:2008 Woda, Woda do spozycia przez ludzi Suma BTEX (z obliczen) PN-EN ISO 15680:2008","categories":["water"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Sum of BTEX (calculated) PN-EN ISO 15680:2008","search_zh":"水、生活饮用水 BTEX 总量（由计算得出） PN-EN ISO 15680:2008","test_object_zh":"水、生活饮用水","methodology_zh":"BTEX 总量（由计算得出）"},{"_id":"6a5dc9bcf1c10c8ce825e211","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Suma ksylenów (z obliczeń)","methodology_en":"Sum of xylenes (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Suma ksylenów (z obliczeń)","reference":"PN-EN ISO 15680:2008","norm_bases":["PN-EN ISO 15680:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Suma ksylenów (z obliczeń) PN-EN ISO 15680:2008 Woda, Woda do spozycia przez ludzi Suma ksylenow (z obliczen) PN-EN ISO 15680:2008","categories":["water"],"row_index":21,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Sum of xylenes (calculated) PN-EN ISO 15680:2008","search_zh":"水、生活饮用水 PN-EN ISO 15680:2008","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9bcf1c10c8ce825e212","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Indeks nadmanganianowy","methodology_en":"Permanganate index","parameters":[{"name":"Zakres","range":"(0,70 - 15) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(0,70 - 15) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Indeks nadmanganianowy\nZakres (0,70 - 15) mg/l O2\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Indeks nadmanganianowy\nZakres (0,70 - 15) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda, Woda do spozycia przez ludzi Indeks nadmanganianowy\nZakres (0,70 - 15) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":22,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Permanganate index Titrimetric method Range PN-EN ISO 8467:2001","methodology_zh":"高锰酸盐指数","parameters_zh":[{"name":"范围","range":"(0,70 - 15) mg/l O2"}],"search_zh":"水、生活饮用水 高锰酸盐指数 滴定法 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9bcf1c10c8ce825e213","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Chemiczne zapotrzebowanie tlenu – ChZT","methodology_en":"Chemical oxygen demand – COD","parameters":[{"name":"Zakres","range":"(10,0 - 150) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(10,0 - 150) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu – ChZT\nZakres (10,0 - 150) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Chemiczne zapotrzebowanie tlenu – ChZT\nZakres (10,0 - 150) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda, Woda do spozycia przez ludzi Chemiczne zapotrzebowanie tlenu – ChZT\nZakres (10,0 - 150) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":23,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Chemical oxygen demand – COD Spectrophotometric method Range PN-ISO 15705:2005","parameters_zh":[{"name":"范围","range":"(10,0 - 150) mg/l O2"}],"search_zh":"水、生活饮用水 化学需氧量 － COD 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","methodology_zh":"化学需氧量 － COD"},{"_id":"6a5dc9bcf1c10c8ce825e214","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Zawiesiny ogólne","methodology_en":"Total suspended solids (TSS)","parameters":[{"name":"Zakres","range":"(2,0 - 35) mg/l"}],"parameters_en":[{"name":"Range","range":"(2,0 - 35) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawiesiny ogólne\nZakres (2,0 - 35) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007 + Ap1:2007","norm_bases":["PN-EN 872:2007 + Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Zawiesiny ogólne\nZakres (2,0 - 35) mg/l\nMetoda wagowa PN-EN 872:2007 + Ap1:2007 Woda, Woda do spozycia przez ludzi Zawiesiny ogolne\nZakres (2,0 - 35) mg/l\nMetoda wagowa PN-EN 872:2007 + Ap1:2007","categories":["water"],"row_index":24,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007 + Ap1:2007","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 - 35) mg/l"}],"search_zh":"水、生活饮用水 总悬浮物 重量法 范围 PN-EN 872:2007 + Ap1:2007","technique_zh":"重量法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9bcf1c10c8ce825e215","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Barwa","methodology_en":"Colour","parameters":[{"name":"Zakres","range":"(2 - 60) mg/l Pt"}],"parameters_en":[{"name":"Range","range":"(2 - 60) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Barwa\nZakres (2 - 60) mg/l Pt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012 Metoda C + Ap1:2015-06","norm_bases":["PN-EN ISO 7887:2012 Metoda C + Ap1:2015-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Barwa\nZakres (2 - 60) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 Metoda C + Ap1:2015-06 Woda, Woda do spozycia przez ludzi Barwa\nZakres (2 - 60) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 Metoda C + Ap1:2015-06","categories":["water"],"row_index":25,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Colour Spectrophotometric method Range PN-EN ISO 7887:2012 Metoda C + Ap1:2015-06","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(2 - 60) mg/l Pt"}],"search_zh":"水、生活饮用水 色度 分光光度法 范围 PN-EN ISO 7887:2012 Metoda C + Ap1:2015-06","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9bcf1c10c8ce825e216","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Zasadowość ogólna","methodology_en":"Total alkalinity","parameters":[{"name":"Zakres","range":"(0,50 - 20,0) mmol/l"}],"parameters_en":[{"name":"Range","range":"(0,50 - 20,0) mmol/l"}],"technique":"Metoda miareczkowania potencjometrycznego","techniques":["Metoda miareczkowania potencjometrycznego"],"technique_en":"Potentiometric titration method","computed":[],"computed_en":[],"activity":"Zasadowość ogólna\nZakres (0,50 - 20,0) mmol/l\nMetoda miareczkowania potencjometrycznego","reference":"PN-EN ISO 9963-1:2001 p. 8.1 + Ap1:2004","norm_bases":["PN-EN ISO 9963-1:2001 p. 8.1 + Ap1:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Zasadowość ogólna\nZakres (0,50 - 20,0) mmol/l\nMetoda miareczkowania potencjometrycznego PN-EN ISO 9963-1:2001 p. 8.1 + Ap1:2004 Woda, Woda do spozycia przez ludzi Zasadowosc ogolna\nZakres (0,50 - 20,0) mmol/l\nMetoda miareczkowania potencjometrycznego PN-EN ISO 9963-1:2001 p. 8.1 + Ap1:2004","categories":["water"],"row_index":26,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Total alkalinity Potentiometric titration method Range PN-EN ISO 9963-1:2001 p. 8.1 + Ap1:2004","parameters_zh":[{"name":"范围","range":"(0,50 - 20,0) mmol/l"}],"search_zh":"水、生活饮用水 总碱度 电位滴定法 范围 PN-EN ISO 9963-1:2001 p. 8.1 + Ap1:2004","technique_zh":"电位滴定法","test_object_zh":"水、生活饮用水","methodology_zh":"总碱度"},{"_id":"6a5dc9bcf1c10c8ce825e217","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Substancje rozpuszczone","methodology_en":"Dissolved solids","parameters":[{"name":"Zakres","range":"(100 - 1800) mg/l"}],"parameters_en":[{"name":"Range","range":"(100 - 1800) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Substancje rozpuszczone\nZakres (100 - 1800) mg/l\nMetoda wagowa","reference":"PN-EN 15216:2022-03","norm_bases":["PN-EN 15216:2022-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Substancje rozpuszczone\nZakres (100 - 1800) mg/l\nMetoda wagowa PN-EN 15216:2022-03 Woda, Woda do spozycia przez ludzi Substancje rozpuszczone\nZakres (100 - 1800) mg/l\nMetoda wagowa PN-EN 15216:2022-03","categories":["water"],"row_index":27,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Dissolved solids Gravimetric method Range PN-EN 15216:2022-03","parameters_zh":[{"name":"范围","range":"(100 - 1800) mg/l"}],"search_zh":"水、生活饮用水 溶解性固体 重量法 范围 PN-EN 15216:2022-03","technique_zh":"重量法","test_object_zh":"水、生活饮用水","methodology_zh":"溶解性固体"},{"_id":"6a5dc9bcf1c10c8ce825e218","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Stężenie pierwiastków","methodology_en":"Element concentration","parameters":[{"name":"antymon","range":"(1,0 - 2000) μg/l"},{"name":"arsen","range":"(1,0 - 2000) μg/l"},{"name":"bar","range":"(1,0 - 2000) μg/l"},{"name":"beryl","range":"(1,0 - 2000) μg/l"},{"name":"bor","range":"(50 - 2000) μg/l"},{"name":"chrom","range":"(0,5 - 2000) μg/l"},{"name":"cyna","range":"(1,0 - 2000) μg/l"},{"name":"cynk","range":"(5,0 - 10000) μg/l"},{"name":"glin","range":"(10 - 2000) μg/l"},{"name":"kadm","range":"(0,10 - 2000) μg/l"},{"name":"kobalt","range":"(0,10 - 2000) μg/l"},{"name":"magnez","range":"(50 - 125000) μg/l"},{"name":"mangan","range":"(1,0 - 2000) μg/l"},{"name":"miedź","range":"(1,0 - 2000) μg/l"},{"name":"molibden","range":"(1,0 - 2000) μg/l"},{"name":"nikiel","range":"(1,0 - 2000) μg/l"},{"name":"ołów","range":"(1,0 - 2000) μg/l"},{"name":"potas","range":"(50 - 100000) μg/l"},{"name":"rtęć","range":"(0,10 - 100) μg/l"},{"name":"selen","range":"(1,0 - 2000) μg/l"},{"name":"srebro","range":"(1,0 - 2000) μg/l"},{"name":"sód","range":"(50 - 500000) μg/l"},{"name":"tytan","range":"(1,0 - 2000) μg/l"},{"name":"uran","range":"(0,10 - 2000) μg/l"},{"name":"wanad","range":"(1,0 - 2000) μg/l"},{"name":"wapń","range":"(50 - 500000) μg/l"},{"name":"żelazo","range":"(10 - 10000) μg/l"}],"parameters_en":[{"name":"antimony","range":"(1,0 - 2000) μg/l"},{"name":"arsenic","range":"(1,0 - 2000) μg/l"},{"name":"barium","range":"(1,0 - 2000) μg/l"},{"name":"beryllium","range":"(1,0 - 2000) μg/l"},{"name":"boron","range":"(50 - 2000) μg/l"},{"name":"chromium","range":"(0,5 - 2000) μg/l"},{"name":"tin","range":"(1,0 - 2000) μg/l"},{"name":"zinc","range":"(5,0 - 10000) μg/l"},{"name":"aluminium","range":"(10 - 2000) μg/l"},{"name":"cadmium","range":"(0,10 - 2000) μg/l"},{"name":"cobalt","range":"(0,10 - 2000) μg/l"},{"name":"magnesium","range":"(50 - 125000) μg/l"},{"name":"manganese","range":"(1,0 - 2000) μg/l"},{"name":"copper","range":"(1,0 - 2000) μg/l"},{"name":"molybdenum","range":"(1,0 - 2000) μg/l"},{"name":"nickel","range":"(1,0 - 2000) μg/l"},{"name":"lead","range":"(1,0 - 2000) μg/l"},{"name":"potassium","range":"(50 - 100000) μg/l"},{"name":"mercury","range":"(0,10 - 100) μg/l"},{"name":"selenium","range":"(1,0 - 2000) μg/l"},{"name":"silver","range":"(1,0 - 2000) μg/l"},{"name":"sodium","range":"(50 - 500000) μg/l"},{"name":"titanium","range":"(1,0 - 2000) μg/l"},{"name":"uranium","range":"(0,10 - 2000) μg/l"},{"name":"vanadium","range":"(1,0 - 2000) μg/l"},{"name":"calcium","range":"(50 - 500000) μg/l"},{"name":"iron","range":"(10 - 10000) μg/l"}],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","computed":[],"computed_en":[],"activity":"Stężenie pierwiastków\nZakres:\nantymon (1,0 - 2000) μg/l\narsen (1,0 - 2000) μg/l\nbar (1,0 - 2000) μg/l\nberyl (1,0 - 2000) μg/l\nbor (50 - 2000) μg/l\nchrom (0,5 - 2000) μg/l\ncyna (1,0 - 2000) μg/l\ncynk (5,0 - 10000) μg/l\nglin (10 - 2000) μg/l\nkadm (0,10 - 2000) μg/l\nkobalt (0,10 - 2000) μg/l\nmagnez (50 - 125000) μg/l\nmangan (1,0 - 2000) μg/l\nmiedź (1,0 - 2000) μg/l\nmolibden (1,0 - 2000) μg/l\nnikiel (1,0 - 2000) μg/l\nołów (1,0 - 2000) μg/l\npotas (50 - 100000) μg/l\nrtęć (0,10 - 100) μg/l\nselen (1,0 - 2000) μg/l\nsrebro (1,0 - 2000) μg/l\nsód (50 - 500000) μg/l\ntytan (1,0 - 2000) μg/l\nuran (0,10 - 2000) μg/l\nwanad (1,0 - 2000) μg/l\nwapń (50 - 500000) μg/l\nżelazo (10 - 10000) μg/l\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"PN-EN ISO 17294-2:2024-04","norm_bases":["PN-EN ISO 17294-2:2024-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie pierwiastków\nZakres:\nantymon (1,0 - 2000) μg/l\narsen (1,0 - 2000) μg/l\nbar (1,0 - 2000) μg/l\nberyl (1,0 - 2000) μg/l\nbor (50 - 2000) μg/l\nchrom (0,5 - 2000) μg/l\ncyna (1,0 - 2000) μg/l\ncynk (5,0 - 10000) μg/l\nglin (10 - 2000) μg/l\nkadm (0,10 - 2000) μg/l\nkobalt (0,10 - 2000) μg/l\nmagnez (50 - 125000) μg/l\nmangan (1,0 - 2000) μg/l\nmiedź (1,0 - 2000) μg/l\nmolibden (1,0 - 2000) μg/l\nnikiel (1,0 - 2000) μg/l\nołów (1,0 - 2000) μg/l\npotas (50 - 100000) μg/l\nrtęć (0,10 - 100) μg/l\nselen (1,0 - 2000) μg/l\nsrebro (1,0 - 2000) μg/l\nsód (50 - 500000) μg/l\ntytan (1,0 - 2000) μg/l\nuran (0,10 - 2000) μg/l\nwanad (1,0 - 2000) μg/l\nwapń (50 - 500000) μg/l\nżelazo (10 - 10000) μg/l\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) PN-EN ISO 17294-2:2024-04 Woda, Woda do spozycia przez ludzi Stezenie pierwiastkow\nZakres:\nantymon (1,0 - 2000) μg/l\narsen (1,0 - 2000) μg/l\nbar (1,0 - 2000) μg/l\nberyl (1,0 - 2000) μg/l\nbor (50 - 2000) μg/l\nchrom (0,5 - 2000) μg/l\ncyna (1,0 - 2000) μg/l\ncynk (5,0 - 10000) μg/l\nglin (10 - 2000) μg/l\nkadm (0,10 - 2000) μg/l\nkobalt (0,10 - 2000) μg/l\nmagnez (50 - 125000) μg/l\nmangan (1,0 - 2000) μg/l\nmiedz (1,0 - 2000) μg/l\nmolibden (1,0 - 2000) μg/l\nnikiel (1,0 - 2000) μg/l\nolow (1,0 - 2000) μg/l\npotas (50 - 100000) μg/l\nrtec (0,10 - 100) μg/l\nselen (1,0 - 2000) μg/l\nsrebro (1,0 - 2000) μg/l\nsod (50 - 500000) μg/l\ntytan (1,0 - 2000) μg/l\nuran (0,10 - 2000) μg/l\nwanad (1,0 - 2000) μg/l\nwapn (50 - 500000) μg/l\nzelazo (10 - 10000) μg/l\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) PN-EN ISO 17294-2:2024-04","categories":["water","materials"],"row_index":28,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Element concentration Inductively coupled plasma mass spectrometry (ICP-MS) antimony arsenic barium beryllium boron chromium tin zinc aluminium cadmium cobalt magnesium manganese copper molybdenum nickel lead potassium mercury selenium silver sodium titanium uranium vanadium calcium iron PN-EN ISO 17294-2:2024-04","methodology_zh":"元素浓度","parameters_zh":[{"name":"锑","range":"(1,0 - 2000) μg/l"},{"name":"砷","range":"(1,0 - 2000) μg/l"},{"name":"钡","range":"(1,0 - 2000) μg/l"},{"name":"铍","range":"(1,0 - 2000) μg/l"},{"name":"硼","range":"(50 - 2000) μg/l"},{"name":"铬","range":"(0,5 - 2000) μg/l"},{"name":"锡","range":"(1,0 - 2000) μg/l"},{"name":"锌","range":"(5,0 - 10000) μg/l"},{"name":"铝","range":"(10 - 2000) μg/l"},{"name":"镉","range":"(0,10 - 2000) μg/l"},{"name":"钴","range":"(0,10 - 2000) μg/l"},{"name":"镁","range":"(50 - 125000) μg/l"},{"name":"锰","range":"(1,0 - 2000) μg/l"},{"name":"铜","range":"(1,0 - 2000) μg/l"},{"name":"钼","range":"(1,0 - 2000) μg/l"},{"name":"镍","range":"(1,0 - 2000) μg/l"},{"name":"铅","range":"(1,0 - 2000) μg/l"},{"name":"钾","range":"(50 - 100000) μg/l"},{"name":"汞","range":"(0,10 - 100) μg/l"},{"name":"硒","range":"(1,0 - 2000) μg/l"},{"name":"银","range":"(1,0 - 2000) μg/l"},{"name":"钠","range":"(50 - 500000) μg/l"},{"name":"钛","range":"(1,0 - 2000) μg/l"},{"name":"铀","range":"(0,10 - 2000) μg/l"},{"name":"钒","range":"(1,0 - 2000) μg/l"},{"name":"钙","range":"(50 - 500000) μg/l"},{"name":"铁","range":"(10 - 10000) μg/l"}],"search_zh":"水、生活饮用水 元素浓度 电感耦合等离子体质谱法（ICP-MS） 锑 砷 钡 铍 硼 铬 锡 锌 铝 镉 钴 镁 锰 铜 钼 镍 铅 钾 汞 硒 银 钠 钛 铀 钒 钙 铁 PN-EN ISO 17294-2:2024-04","technique_zh":"电感耦合等离子体质谱法（ICP-MS）","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9bcf1c10c8ce825e219","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Twardość ogólna z obliczeń","methodology_en":"Total hardness calculated","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Twardość ogólna z obliczeń","reference":"TL-PB-88 wyd. 2 z dnia 05.12.2022 r.","norm_bases":["TL-PB-88 wyd. 2 z dnia 05.12.2022 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Twardość ogólna z obliczeń TL-PB-88 wyd. 2 z dnia 05.12.2022 r. Woda, Woda do spozycia przez ludzi Twardosc ogolna z obliczen TL-PB-88 wyd. 2 z dnia 05.12.2022 r.","categories":["water"],"row_index":29,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Total hardness calculated TL-PB-88 wyd. 2 z dnia 05.12.2022 r.","search_zh":"水、生活饮用水 TL-PB-88 wyd. 2 z dnia 05.12.2022 r.","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9bcf1c10c8ce825e21a","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Pobieranie próbek do badań chemicznych i fizycznych (w tym sensorycznych)","methodology_en":"Sampling for chemical and physical testing (including sensory testing)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych (w tym sensorycznych)","reference":"PN-ISO 5667-5:2017-10","norm_bases":["PN-ISO 5667-5:2017-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych (w tym sensorycznych) PN-ISO 5667-5:2017-10 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych (w tym sensorycznych) PN-ISO 5667-5:2017-10","categories":["water"],"row_index":30,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Sampling for chemical and physical testing (including sensory testing) PN-ISO 5667-5:2017-10","search_zh":"生活饮用水 化学和物理检测采样（含感官检测） PN-ISO 5667-5:2017-10","test_object_zh":"生活饮用水","methodology_zh":"化学和物理检测采样（含感官检测）"},{"_id":"6a5dc9bcf1c10c8ce825e21b","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Pobieranie próbek do badań chemicznych i fizycznych (w tym sensorycznych)","methodology_en":"Sampling for chemical and physical testing (including sensory testing)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych (w tym sensorycznych)","reference":"PN-ISO 5667-11:2017-10","norm_bases":["PN-ISO 5667-11:2017-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych (w tym sensorycznych) PN-ISO 5667-11:2017-10 Woda Pobieranie probek do badan chemicznych i fizycznych (w tym sensorycznych) PN-ISO 5667-11:2017-10","categories":["water"],"row_index":31,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Sampling for chemical and physical testing (including sensory testing) PN-ISO 5667-11:2017-10","search_zh":"水 化学和物理检测采样（含感官检测） PN-ISO 5667-11:2017-10","test_object_zh":"水","methodology_zh":"化学和物理检测采样（含感官检测）"},{"_id":"6a5dc9bcf1c10c8ce825e21c","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Pobieranie próbek do badań mikrobiologicznych","methodology_en":"Sampling for microbiological testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007","norm_bases":["PN-EN ISO 19458:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 Woda, Woda do spozycia przez ludzi Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007","categories":["water","microbiology"],"row_index":32,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007","methodology_zh":"微生物检测用样品采集","search_zh":"水、生活饮用水 微生物检测用样品采集 PN-EN ISO 19458:2007","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9bcf1c10c8ce825e21d","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":"Metoda automatyczna","techniques":["Metoda automatyczna"],"technique_en":"Automatic method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda automatyczna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nMetoda automatyczna PN-ISO 5667-10:2021-11 Scieki Pobieranie probek do badan chemicznych i fizycznych\nMetoda automatyczna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":33,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Sampling for chemical and physical testing Automatic method PN-ISO 5667-10:2021-11","methodology_zh":"化学与物理检测用样品采集","search_zh":"污水 化学与物理检测用样品采集 自动法 PN-ISO 5667-10:2021-11","test_object_zh":"污水","technique_zh":"自动法"},{"_id":"6a5dc9bcf1c10c8ce825e21e","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"4,0 - 12,0"}],"parameters_en":[{"name":"Range","range":"4,0 - 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 4,0 - 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki pH\nZakres 4,0 - 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Scieki pH\nZakres 4,0 - 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":34,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 - 12,0"}],"search_zh":"污水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"污水"},{"_id":"6a5dc9bcf1c10c8ce825e21f","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Przewodność elektryczna właściwa","methodology_en":"Electrical conductivity","parameters":[{"name":"Zakres","range":"150 μS/cm - 200 mS/cm"}],"parameters_en":[{"name":"Range","range":"150 μS/cm - 200 mS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"technique_en":"Conductometric method","computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa\nZakres 150 μS/cm - 200 mS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Przewodność elektryczna właściwa\nZakres 150 μS/cm - 200 mS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Scieki Przewodnosc elektryczna wlasciwa\nZakres 150 μS/cm - 200 mS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":35,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Electrical conductivity Conductometric method Range PN-EN 27888:1999","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"150 μS/cm - 200 mS/cm"}],"search_zh":"污水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"污水"},{"_id":"6a5dc9bcf1c10c8ce825e220","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie ortofosforanów","methodology_en":"Orthophosphate concentration","parameters":[{"name":"Zakres","range":"(0,05 - 50,0) mg/l P-PO43-;"},{"name":"Zakres","range":"(0,015 - 153) mg/l PO43-"}],"parameters_en":[{"name":"Range","range":"(0,05 - 50,0) mg/l P-PO43-;"},{"name":"Range","range":"(0,015 - 153) mg/l PO43-"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie ortofosforanów\nZakres:\nZakres (0,05 - 50,0) mg/l P-PO43-;\nZakres (0,015 - 153) mg/l PO43-\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 pkt 4 + Ap1:2010 + Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 pkt 4 + Ap1:2010 + Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie ortofosforanów\nZakres:\nZakres (0,05 - 50,0) mg/l P-PO43-;\nZakres (0,015 - 153) mg/l PO43-\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt 4 + Ap1:2010 + Ap2:2010 Scieki Stezenie ortofosforanow\nZakres:\nZakres (0,05 - 50,0) mg/l P-PO43-;\nZakres (0,015 - 153) mg/l PO43-\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt 4 + Ap1:2010 + Ap2:2010","categories":["water"],"row_index":36,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Orthophosphate concentration Spectrophotometric method Range Range PN-EN ISO 6878:2006 pkt 4 + Ap1:2010 + Ap2:2010","parameters_zh":[{"name":"范围","range":"(0,05 - 50,0) mg/l P-PO43-;"},{"name":"范围","range":"(0,015 - 153) mg/l PO43-"}],"search_zh":"污水 正磷酸盐浓度 分光光度法 范围 范围 PN-EN ISO 6878:2006 pkt 4 + Ap1:2010 + Ap2:2010","technique_zh":"分光光度法","test_object_zh":"污水","methodology_zh":"正磷酸盐浓度"},{"_id":"6a5dc9bcf1c10c8ce825e221","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Zasadowość ogólna","methodology_en":"Total alkalinity","parameters":[{"name":"Zakres","range":"(0,5 - 20,0) mmol/l"}],"parameters_en":[{"name":"Range","range":"(0,5 - 20,0) mmol/l"}],"technique":"Metoda miareczkowania potencjometrycznego","techniques":["Metoda miareczkowania potencjometrycznego"],"technique_en":"Potentiometric titration method","computed":[],"computed_en":[],"activity":"Zasadowość ogólna\nZakres (0,5 - 20,0) mmol/l\nMetoda miareczkowania potencjometrycznego","reference":"PN-EN ISO 9963-1:2001 p. 8.1 + Ap1:2004","norm_bases":["PN-EN ISO 9963-1:2001 p. 8.1 + Ap1:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Zasadowość ogólna\nZakres (0,5 - 20,0) mmol/l\nMetoda miareczkowania potencjometrycznego PN-EN ISO 9963-1:2001 p. 8.1 + Ap1:2004 Scieki Zasadowosc ogolna\nZakres (0,5 - 20,0) mmol/l\nMetoda miareczkowania potencjometrycznego PN-EN ISO 9963-1:2001 p. 8.1 + Ap1:2004","categories":["water"],"row_index":37,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Total alkalinity Potentiometric titration method Range PN-EN ISO 9963-1:2001 p. 8.1 + Ap1:2004","parameters_zh":[{"name":"范围","range":"(0,5 - 20,0) mmol/l"}],"search_zh":"污水 总碱度 电位滴定法 范围 PN-EN ISO 9963-1:2001 p. 8.1 + Ap1:2004","technique_zh":"电位滴定法","test_object_zh":"污水","methodology_zh":"总碱度"},{"_id":"6a5dc9bcf1c10c8ce825e222","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Zawiesiny ogólne","methodology_en":"Total suspended solids (TSS)","parameters":[{"name":"Zakres","range":"(5,0 - 5000) mg/l"}],"parameters_en":[{"name":"Range","range":"(5,0 - 5000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawiesiny ogólne\nZakres (5,0 - 5000) mg/l\nMetoda wagowa","reference":"PN-EN 872: 2007+Ap1:2007","norm_bases":["PN-EN 872: 2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Zawiesiny ogólne\nZakres (5,0 - 5000) mg/l\nMetoda wagowa PN-EN 872: 2007+Ap1:2007 Scieki Zawiesiny ogolne\nZakres (5,0 - 5000) mg/l\nMetoda wagowa PN-EN 872: 2007+Ap1:2007","categories":["water"],"row_index":38,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872: 2007+Ap1:2007","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(5,0 - 5000) mg/l"}],"search_zh":"污水 总悬浮物 重量法 范围 PN-EN 872: 2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"污水"},{"_id":"6a5dc9bcf1c10c8ce825e223","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu azotynowego","methodology_en":"Nitrite nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,002 - 3,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,002 - 3,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu azotynowego\nZakres (0,002 - 3,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu azotynowego\nZakres (0,002 - 3,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Scieki Stezenie azotu azotynowego\nZakres (0,002 - 3,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":39,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Nitrite nitrogen concentration Spectrophotometric method Range PN-EN 26777:1999","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,002 - 3,0) mg/l"}],"search_zh":"污水 亚硝态氮浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a5dc9bcf1c10c8ce825e224","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu azotanowego","methodology_en":"Nitrate nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,040 - 100) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,040 - 100) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu azotanowego\nZakres (0,040 - 100) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu azotanowego\nZakres (0,040 - 100) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08 Scieki Stezenie azotu azotanowego\nZakres (0,040 - 100) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":40,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Nitrate nitrogen concentration Spectrophotometric method Range PN-82/C-04576/08","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,040 - 100) mg/l"}],"search_zh":"污水 硝态氮浓度 分光光度法 范围 PN-82/C-04576/08","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a5dc9bcf1c10c8ce825e225","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu amonowego","methodology_en":"Ammonium nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,3 - 20) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,3 - 20) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego\nZakres (0,3 - 20) mg/l\nMetoda spektrofotometryczna","reference":"PN-C -04576-4:1994","norm_bases":["PN-C -04576-4:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu amonowego\nZakres (0,3 - 20) mg/l\nMetoda spektrofotometryczna PN-C -04576-4:1994 Scieki Stezenie azotu amonowego\nZakres (0,3 - 20) mg/l\nMetoda spektrofotometryczna PN-C -04576-4:1994","categories":["water"],"row_index":41,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Ammonium nitrogen concentration Spectrophotometric method Range PN-C -04576-4:1994","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,3 - 20) mg/l"}],"search_zh":"污水 氨氮浓度 分光光度法 范围 PN-C -04576-4:1994","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a5dc9bcf1c10c8ce825e226","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu amonowego","methodology_en":"Ammonium nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,7 - 2000) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,7 - 2000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego\nZakres (0,7 - 2000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu amonowego\nZakres (0,7 - 2000) mg/l\nMetoda miareczkowa PN-ISO 5664:2002 Scieki Stezenie azotu amonowego\nZakres (0,7 - 2000) mg/l\nMetoda miareczkowa PN-ISO 5664:2002","categories":["water"],"row_index":42,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Ammonium nitrogen concentration Titrimetric method Range PN-ISO 5664:2002","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,7 - 2000) mg/l"}],"search_zh":"污水 氨氮浓度 滴定法 范围 PN-ISO 5664:2002","technique_zh":"滴定法","test_object_zh":"污水"},{"_id":"6a5dc9bcf1c10c8ce825e227","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu Kjeldahla","methodology_en":"Kjeldahl nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,8 - 2500) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,8 - 2500) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie azotu Kjeldahla\nZakres (0,8 - 2500) mg/l\nMetoda miareczkowa","reference":"TL-PB-46 wydanie 1 z dnia 25.09.2020 r.","norm_bases":["TL-PB-46 wydanie 1 z dnia 25.09.2020 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu Kjeldahla\nZakres (0,8 - 2500) mg/l\nMetoda miareczkowa TL-PB-46 wydanie 1 z dnia 25.09.2020 r. Scieki Stezenie azotu Kjeldahla\nZakres (0,8 - 2500) mg/l\nMetoda miareczkowa TL-PB-46 wydanie 1 z dnia 25.09.2020 r.","categories":["water"],"row_index":43,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Kjeldahl nitrogen concentration Titrimetric method Range TL-PB-46 wydanie 1 z dnia 25.09.2020 r.","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(0,8 - 2500) mg/l"}],"search_zh":"污水 凯氏氮浓度 滴定法 范围 TL-PB-46 wydanie 1 z dnia 25.09.2020 r.","technique_zh":"滴定法","test_object_zh":"污水"},{"_id":"6a5dc9bcf1c10c8ce825e228","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu Kjeldahla, Zakres; (0,3 - 10) mg/l","methodology_en":"Kjeldahl nitrogen concentration, Range; (0,3 - 10) mg/l","parameters":[],"parameters_en":[],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu Kjeldahla, Zakres; (0,3 - 10) mg/l\nMetoda spektrofotometryczna","reference":"TL-PB-47 wydanie 1 z dnia 25.09.2020 r.","norm_bases":["TL-PB-47 wydanie 1 z dnia 25.09.2020 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu Kjeldahla, Zakres; (0,3 - 10) mg/l\nMetoda spektrofotometryczna TL-PB-47 wydanie 1 z dnia 25.09.2020 r. Scieki Stezenie azotu Kjeldahla, Zakres; (0,3 - 10) mg/l\nMetoda spektrofotometryczna TL-PB-47 wydanie 1 z dnia 25.09.2020 r.","categories":["water"],"row_index":44,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Kjeldahl nitrogen concentration, Range; (0,3 - 10) mg/l Spectrophotometric method TL-PB-47 wydanie 1 z dnia 25.09.2020 r.","search_zh":"污水 分光光度法 TL-PB-47 wydanie 1 z dnia 25.09.2020 r.","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a5dc9bcf1c10c8ce825e229","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu ogólnego (z obliczeń)","methodology_en":"Total nitrogen concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"TL-PB-46 wydanie 1 z dnia 25.09.2020 r. TL-PB-47 wydanie 1 z dnia 25.09.2020 r.","norm_bases":["TL-PB-46 wydanie 1 z dnia 25.09.2020 r. TL-PB-47 wydanie 1 z dnia 25.09.2020 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu ogólnego (z obliczeń) TL-PB-46 wydanie 1 z dnia 25.09.2020 r. TL-PB-47 wydanie 1 z dnia 25.09.2020 r. Scieki Stezenie azotu ogolnego (z obliczen) TL-PB-46 wydanie 1 z dnia 25.09.2020 r. TL-PB-47 wydanie 1 z dnia 25.09.2020 r.","categories":["water"],"row_index":45,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Total nitrogen concentration (calculated) TL-PB-46 wydanie 1 z dnia 25.09.2020 r. TL-PB-47 wydanie 1 z dnia 25.09.2020 r.","methodology_zh":"总氮浓度（计算值）","search_zh":"污水 总氮浓度（计算值） TL-PB-46 wydanie 1 z dnia 25.09.2020 r. TL-PB-47 wydanie 1 z dnia 25.09.2020 r.","test_object_zh":"污水"},{"_id":"6a5dc9bcf1c10c8ce825e22a","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Chemiczne zapotrzebowanie tlenu - CHZT","methodology_en":"Chemical oxygen demand - COD","parameters":[{"name":"Zakres","range":"(10 - 10000) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(10 - 10000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu - CHZT\nZakres (10 - 10000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Chemiczne zapotrzebowanie tlenu - CHZT\nZakres (10 - 10000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Scieki Chemiczne zapotrzebowanie tlenu - CHZT\nZakres (10 - 10000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":46,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Chemical oxygen demand - COD Spectrophotometric method Range PN-ISO 15705:2005","parameters_zh":[{"name":"范围","range":"(10 - 10000) mg/l O2"}],"search_zh":"污水 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a5dc9bcf1c10c8ce825e22b","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5","methodology_en":"Biochemical oxygen demand - BOD5","parameters":[{"name":"Zakres","range":"(3 - 3000) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(3 - 3000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (3 - 3000) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (3 - 3000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Scieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (3 - 3000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":47,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Biochemical oxygen demand - BOD5 Electrochemical method Range PN-EN ISO 5815-1:2019-12","parameters_zh":[{"name":"范围","range":"(3 - 3000) mg/l O2"}],"search_zh":"污水 五日生化需氧量（BOD5） 电化学法 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"污水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a5dc9bcf1c10c8ce825e22c","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie chlorków","methodology_en":"Chloride concentration","parameters":[{"name":"Zakres","range":"(10 - 5000) mg/l"}],"parameters_en":[{"name":"Range","range":"(10 - 5000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie chlorków\nZakres (10 - 5000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie chlorków\nZakres (10 - 5000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Scieki Stezenie chlorkow\nZakres (10 - 5000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":48,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Chloride concentration Titrimetric method Range PN-ISO 9297:1994","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(10 - 5000) mg/l"}],"search_zh":"污水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"污水"},{"_id":"6a5dc9bcf1c10c8ce825e22d","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie fosforu ogólnego","methodology_en":"Total phosphorus concentration","parameters":[{"name":"Zakres","range":"(0,05 - 50) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,05 - 50) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,05 - 50) mg/l\nMetoda spektrofotometryczna","reference":"TL-PB-45 wydanie 1 z dnia 25.09.2020 r. | na podstawie testów kuwetowych MERCK nr 1.14543.0001 i 1.14729.0001","norm_bases":["TL-PB-45 wydanie 1 z dnia 25.09.2020 r.","na podstawie testów kuwetowych MERCK nr 1.14543.0001 i 1.14729.0001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie fosforu ogólnego\nZakres (0,05 - 50) mg/l\nMetoda spektrofotometryczna TL-PB-45 wydanie 1 z dnia 25.09.2020 r. | na podstawie testów kuwetowych MERCK nr 1.14543.0001 i 1.14729.0001 Scieki Stezenie fosforu ogolnego\nZakres (0,05 - 50) mg/l\nMetoda spektrofotometryczna TL-PB-45 wydanie 1 z dnia 25.09.2020 r. | na podstawie testow kuwetowych MERCK nr 1.14543.0001 i 1.14729.0001","categories":["water"],"row_index":49,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Total phosphorus concentration Spectrophotometric method Range TL-PB-45 wydanie 1 z dnia 25.09.2020 r. | na podstawie testów kuwetowych MERCK nr 1.14543.0001 i 1.14729.0001","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,05 - 50) mg/l"}],"search_zh":"污水 总磷浓度 分光光度法 范围 TL-PB-45 wydanie 1 z dnia 25.09.2020 r. | na podstawie testów kuwetowych MERCK nr 1.14543.0001 i 1.14729.0001","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a5dc9bcf1c10c8ce825e22e","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie fosforu fosforanowego","methodology_en":"Phosphate phosphorus concentration","parameters":[{"name":"Zakres","range":"(0,05 - 50) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,05 - 50) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie fosforu fosforanowego\nZakres (0,05 - 50) mg/l\nMetoda spektrofotometryczna","reference":"TL-PB-45 wydanie 1 z dnia 25.09.2020 r. | na podstawie testów kuwetowych MERCK nr 1.14543.0001 i 1.14729.0001","norm_bases":["TL-PB-45 wydanie 1 z dnia 25.09.2020 r.","na podstawie testów kuwetowych MERCK nr 1.14543.0001 i 1.14729.0001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie fosforu fosforanowego\nZakres (0,05 - 50) mg/l\nMetoda spektrofotometryczna TL-PB-45 wydanie 1 z dnia 25.09.2020 r. | na podstawie testów kuwetowych MERCK nr 1.14543.0001 i 1.14729.0001 Scieki Stezenie fosforu fosforanowego\nZakres (0,05 - 50) mg/l\nMetoda spektrofotometryczna TL-PB-45 wydanie 1 z dnia 25.09.2020 r. | na podstawie testow kuwetowych MERCK nr 1.14543.0001 i 1.14729.0001","categories":["water"],"row_index":50,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Phosphate phosphorus concentration Spectrophotometric method Range TL-PB-45 wydanie 1 z dnia 25.09.2020 r. | na podstawie testów kuwetowych MERCK nr 1.14543.0001 i 1.14729.0001","parameters_zh":[{"name":"范围","range":"(0,05 - 50) mg/l"}],"search_zh":"污水 磷酸盐磷浓度 分光光度法 范围 TL-PB-45 wydanie 1 z dnia 25.09.2020 r. | na podstawie testów kuwetowych MERCK nr 1.14543.0001 i 1.14729.0001","technique_zh":"分光光度法","test_object_zh":"污水","methodology_zh":"磷酸盐磷浓度"},{"_id":"6a5dc9bcf1c10c8ce825e22f","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu amonowego","methodology_en":"Ammonium nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,20 - 2,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,20 - 2,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego\nZakres (0,20 - 2,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1: 2002","norm_bases":["PN-ISO 7150-1: 2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu amonowego\nZakres (0,20 - 2,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1: 2002 Scieki Stezenie azotu amonowego\nZakres (0,20 - 2,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1: 2002","categories":["water"],"row_index":51,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Ammonium nitrogen concentration Spectrophotometric method Range PN-ISO 7150-1: 2002","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,20 - 2,0) mg/l"}],"search_zh":"污水 氨氮浓度 分光光度法 范围 PN-ISO 7150-1: 2002","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a5dc9bcf1c10c8ce825e230","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie substancji ekstrahujących się eterem naftowym","methodology_en":"Concentration of substances extractable with petroleum ether","parameters":[{"name":"Zakres","range":"(10 - 1000) mg/l"}],"parameters_en":[{"name":"Range","range":"(10 - 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie substancji ekstrahujących się eterem naftowym\nZakres (10 - 1000) mg/l\nMetoda wagowa","reference":"TL-PB-54 wydanie 2 z dnia 28.01.2022 r.","norm_bases":["TL-PB-54 wydanie 2 z dnia 28.01.2022 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie substancji ekstrahujących się eterem naftowym\nZakres (10 - 1000) mg/l\nMetoda wagowa TL-PB-54 wydanie 2 z dnia 28.01.2022 r. Scieki Stezenie substancji ekstrahujacych sie eterem naftowym\nZakres (10 - 1000) mg/l\nMetoda wagowa TL-PB-54 wydanie 2 z dnia 28.01.2022 r.","categories":["water"],"row_index":52,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Concentration of substances extractable with petroleum ether Gravimetric method Range TL-PB-54 wydanie 2 z dnia 28.01.2022 r.","parameters_zh":[{"name":"范围","range":"(10 - 1000) mg/l"}],"search_zh":"污水 石油醚可萃取物浓度 重量法 范围 TL-PB-54 wydanie 2 z dnia 28.01.2022 r.","technique_zh":"重量法","test_object_zh":"污水","methodology_zh":"石油醚可萃取物浓度"},{"_id":"6a5dc9bcf1c10c8ce825e231","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie siarczanów","methodology_en":"Sulfate concentration","parameters":[{"name":"Zakres","range":"(30 - 1000) mg/l"}],"parameters_en":[{"name":"Range","range":"(30 - 1000) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie siarczanów\nZakres (30 - 1000) mg/l\nMetoda spektrofotometryczna","reference":"TL-PB-51 wydanie 1 z dnia 25.09.2020 r. na podstawie testów kuwetowych MERCK nr 1.14548.0001 i 1.14564.0001","norm_bases":["TL-PB-51 wydanie 1 z dnia 25.09.2020 r. na podstawie testów kuwetowych MERCK nr 1.14548.0001 i 1.14564.0001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie siarczanów\nZakres (30 - 1000) mg/l\nMetoda spektrofotometryczna TL-PB-51 wydanie 1 z dnia 25.09.2020 r. na podstawie testów kuwetowych MERCK nr 1.14548.0001 i 1.14564.0001 Scieki Stezenie siarczanow\nZakres (30 - 1000) mg/l\nMetoda spektrofotometryczna TL-PB-51 wydanie 1 z dnia 25.09.2020 r. na podstawie testow kuwetowych MERCK nr 1.14548.0001 i 1.14564.0001","categories":["water"],"row_index":53,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Sulfate concentration Spectrophotometric method Range TL-PB-51 wydanie 1 z dnia 25.09.2020 r. na podstawie testów kuwetowych MERCK nr 1.14548.0001 i 1.14564.0001","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(30 - 1000) mg/l"}],"search_zh":"污水 硫酸盐浓度 分光光度法 范围 TL-PB-51 wydanie 1 z dnia 25.09.2020 r. na podstawie testów kuwetowych MERCK nr 1.14548.0001 i 1.14564.0001","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a5dc9bcf1c10c8ce825e232","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie anionowych substancji powierzchniowo czynnych","methodology_en":"Anionic surfactants concentration","parameters":[{"name":"Zakres","range":"(0,50 – 100) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,50 – 100) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie anionowych substancji powierzchniowo czynnych\nZakres (0,50 – 100) mg/l\nMetoda spektrofotometryczna","reference":"TL-PB-81 wyd.1 z dnia 16.08.2021 na podstawie testów kuwetowych MERCK nr 1.02552.0001","norm_bases":["TL-PB-81 wyd.1 z dnia 16.08.2021 na podstawie testów kuwetowych MERCK nr 1.02552.0001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie anionowych substancji powierzchniowo czynnych\nZakres (0,50 – 100) mg/l\nMetoda spektrofotometryczna TL-PB-81 wyd.1 z dnia 16.08.2021 na podstawie testów kuwetowych MERCK nr 1.02552.0001 Scieki Stezenie anionowych substancji powierzchniowo czynnych\nZakres (0,50 – 100) mg/l\nMetoda spektrofotometryczna TL-PB-81 wyd.1 z dnia 16.08.2021 na podstawie testow kuwetowych MERCK nr 1.02552.0001","categories":["water"],"row_index":54,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Anionic surfactants concentration Spectrophotometric method Range TL-PB-81 wyd.1 z dnia 16.08.2021 na podstawie testów kuwetowych MERCK nr 1.02552.0001","parameters_zh":[{"name":"范围","range":"(0,50 – 100) mg/l"}],"search_zh":"污水 分光光度法 范围 TL-PB-81 wyd.1 z dnia 16.08.2021 na podstawie testów kuwetowych MERCK nr 1.02552.0001","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a5dc9bcf1c10c8ce825e233","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie niejonowych substancji powierzchniowo czynnych","methodology_en":"Concentration of non-ionic surfactants","parameters":[{"name":"Zakres","range":"(1,0 – 100) mg/l"}],"parameters_en":[{"name":"Range","range":"(1,0 – 100) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie niejonowych substancji powierzchniowo czynnych\nZakres (1,0 – 100) mg/l\nMetoda spektrofotometryczna","reference":"TL-PB-82 wyd.1 z dnia 16.08.2021 na podstawie testów kuwetowych MERCK nr 1.01787.0001","norm_bases":["TL-PB-82 wyd.1 z dnia 16.08.2021 na podstawie testów kuwetowych MERCK nr 1.01787.0001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie niejonowych substancji powierzchniowo czynnych\nZakres (1,0 – 100) mg/l\nMetoda spektrofotometryczna TL-PB-82 wyd.1 z dnia 16.08.2021 na podstawie testów kuwetowych MERCK nr 1.01787.0001 Scieki Stezenie niejonowych substancji powierzchniowo czynnych\nZakres (1,0 – 100) mg/l\nMetoda spektrofotometryczna TL-PB-82 wyd.1 z dnia 16.08.2021 na podstawie testow kuwetowych MERCK nr 1.01787.0001","categories":["water"],"row_index":55,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Concentration of non-ionic surfactants Spectrophotometric method Range TL-PB-82 wyd.1 z dnia 16.08.2021 na podstawie testów kuwetowych MERCK nr 1.01787.0001","parameters_zh":[{"name":"范围","range":"(1,0 – 100) mg/l"}],"search_zh":"污水 分光光度法 范围 TL-PB-82 wyd.1 z dnia 16.08.2021 na podstawie testów kuwetowych MERCK nr 1.01787.0001","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a5dc9bcf1c10c8ce825e234","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie pierwiastków","methodology_en":"Element concentration","parameters":[{"name":"antymon","range":"(1,0 - 2000) μg/l"},{"name":"arsen","range":"(1,0 - 2000) μg/l"},{"name":"bar","range":"(1,0 - 2000) μg/l"},{"name":"beryl","range":"(1,0 - 2000) μg/l"},{"name":"bor","range":"(50 - 2000) μg/l"},{"name":"chrom","range":"(0,5 - 2000) μg/l"},{"name":"cyna","range":"(1,0 - 2000) μg/l"},{"name":"cynk","range":"(5,0 - 10000) μg/l"},{"name":"fosfor ogólny","range":"(50 - 100000) μg/l"},{"name":"glin","range":"(10 - 2000) μg/l"},{"name":"kadm","range":"(0,10 - 2000) μg/l"},{"name":"kobalt","range":"(0,10 - 2000) μg/l"},{"name":"mangan","range":"(1,0 - 2000) μg/l"},{"name":"miedź","range":"(1,0 - 2000) μg/l"},{"name":"molibden","range":"(1,0 - 2000) μg/l"},{"name":"nikiel","range":"(1,0 - 2000) μg/l"},{"name":"ołów","range":"(1,0 - 2000) μg/l"},{"name":"rtęć","range":"(0,10 - 100) μg/l"},{"name":"selen","range":"(1,0 - 2000) μg/l"},{"name":"srebro","range":"(1,0 - 2000) μg/l"},{"name":"tal","range":"(1,0 - 2000) μg/l"},{"name":"tytan","range":"(1,0 - 2000) μg/l"},{"name":"wanad","range":"(1,0 - 2000) μg/l"},{"name":"uran","range":"(0,10 - 2000) μg/l"},{"name":"żelazo","range":"(10 - 10000) μg/l"}],"parameters_en":[{"name":"antimony","range":"(1,0 - 2000) μg/l"},{"name":"arsenic","range":"(1,0 - 2000) μg/l"},{"name":"barium","range":"(1,0 - 2000) μg/l"},{"name":"beryllium","range":"(1,0 - 2000) μg/l"},{"name":"boron","range":"(50 - 2000) μg/l"},{"name":"chromium","range":"(0,5 - 2000) μg/l"},{"name":"tin","range":"(1,0 - 2000) μg/l"},{"name":"zinc","range":"(5,0 - 10000) μg/l"},{"name":"total phosphorus","range":"(50 - 100000) μg/l"},{"name":"aluminium","range":"(10 - 2000) μg/l"},{"name":"cadmium","range":"(0,10 - 2000) μg/l"},{"name":"cobalt","range":"(0,10 - 2000) μg/l"},{"name":"manganese","range":"(1,0 - 2000) μg/l"},{"name":"copper","range":"(1,0 - 2000) μg/l"},{"name":"molybdenum","range":"(1,0 - 2000) μg/l"},{"name":"nickel","range":"(1,0 - 2000) μg/l"},{"name":"lead","range":"(1,0 - 2000) μg/l"},{"name":"mercury","range":"(0,10 - 100) μg/l"},{"name":"selenium","range":"(1,0 - 2000) μg/l"},{"name":"silver","range":"(1,0 - 2000) μg/l"},{"name":"thallium","range":"(1,0 - 2000) μg/l"},{"name":"titanium","range":"(1,0 - 2000) μg/l"},{"name":"vanadium","range":"(1,0 - 2000) μg/l"},{"name":"uranium","range":"(0,10 - 2000) μg/l"},{"name":"iron","range":"(10 - 10000) μg/l"}],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","computed":[],"computed_en":[],"activity":"Stężenie pierwiastków\nZakres:\nantymon (1,0 - 2000) μg/l\narsen (1,0 - 2000) μg/l\nbar (1,0 - 2000) μg/l\nberyl (1,0 - 2000) μg/l\nbor (50 - 2000) μg/l\nchrom (0,5 - 2000) μg/l\ncyna (1,0 - 2000) μg/l\ncynk (5,0 - 10000) μg/l\nfosfor ogólny (50 - 100000) μg/l\nglin (10 - 2000) μg/l\nkadm (0,10 - 2000) μg/l\nkobalt (0,10 - 2000) μg/l\nmangan (1,0 - 2000) μg/l\nmiedź (1,0 - 2000) μg/l\nmolibden (1,0 - 2000) μg/l\nnikiel (1,0 - 2000) μg/l\nołów (1,0 - 2000) μg/l\nrtęć (0,10 - 100) μg/l\nselen (1,0 - 2000) μg/l\nsrebro (1,0 - 2000) μg/l\ntal (1,0 - 2000) μg/l\ntytan (1,0 - 2000) μg/l\nwanad (1,0 - 2000) μg/l\nuran (0,10 - 2000) μg/l\nżelazo (10 - 10000) μg/l\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"PN-EN ISO 17294-2:2024-04","norm_bases":["PN-EN ISO 17294-2:2024-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie pierwiastków\nZakres:\nantymon (1,0 - 2000) μg/l\narsen (1,0 - 2000) μg/l\nbar (1,0 - 2000) μg/l\nberyl (1,0 - 2000) μg/l\nbor (50 - 2000) μg/l\nchrom (0,5 - 2000) μg/l\ncyna (1,0 - 2000) μg/l\ncynk (5,0 - 10000) μg/l\nfosfor ogólny (50 - 100000) μg/l\nglin (10 - 2000) μg/l\nkadm (0,10 - 2000) μg/l\nkobalt (0,10 - 2000) μg/l\nmangan (1,0 - 2000) μg/l\nmiedź (1,0 - 2000) μg/l\nmolibden (1,0 - 2000) μg/l\nnikiel (1,0 - 2000) μg/l\nołów (1,0 - 2000) μg/l\nrtęć (0,10 - 100) μg/l\nselen (1,0 - 2000) μg/l\nsrebro (1,0 - 2000) μg/l\ntal (1,0 - 2000) μg/l\ntytan (1,0 - 2000) μg/l\nwanad (1,0 - 2000) μg/l\nuran (0,10 - 2000) μg/l\nżelazo (10 - 10000) μg/l\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) PN-EN ISO 17294-2:2024-04 Scieki Stezenie pierwiastkow\nZakres:\nantymon (1,0 - 2000) μg/l\narsen (1,0 - 2000) μg/l\nbar (1,0 - 2000) μg/l\nberyl (1,0 - 2000) μg/l\nbor (50 - 2000) μg/l\nchrom (0,5 - 2000) μg/l\ncyna (1,0 - 2000) μg/l\ncynk (5,0 - 10000) μg/l\nfosfor ogolny (50 - 100000) μg/l\nglin (10 - 2000) μg/l\nkadm (0,10 - 2000) μg/l\nkobalt (0,10 - 2000) μg/l\nmangan (1,0 - 2000) μg/l\nmiedz (1,0 - 2000) μg/l\nmolibden (1,0 - 2000) μg/l\nnikiel (1,0 - 2000) μg/l\nolow (1,0 - 2000) μg/l\nrtec (0,10 - 100) μg/l\nselen (1,0 - 2000) μg/l\nsrebro (1,0 - 2000) μg/l\ntal (1,0 - 2000) μg/l\ntytan (1,0 - 2000) μg/l\nwanad (1,0 - 2000) μg/l\nuran (0,10 - 2000) μg/l\nzelazo (10 - 10000) μg/l\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) PN-EN ISO 17294-2:2024-04","categories":["water","materials"],"row_index":56,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Element concentration Inductively coupled plasma mass spectrometry (ICP-MS) antimony arsenic barium beryllium boron chromium tin zinc total phosphorus aluminium cadmium cobalt manganese copper molybdenum nickel lead mercury selenium silver thallium titanium vanadium uranium iron PN-EN ISO 17294-2:2024-04","methodology_zh":"元素浓度","parameters_zh":[{"name":"锑","range":"(1,0 - 2000) μg/l"},{"name":"砷","range":"(1,0 - 2000) μg/l"},{"name":"钡","range":"(1,0 - 2000) μg/l"},{"name":"铍","range":"(1,0 - 2000) μg/l"},{"name":"硼","range":"(50 - 2000) μg/l"},{"name":"铬","range":"(0,5 - 2000) μg/l"},{"name":"锡","range":"(1,0 - 2000) μg/l"},{"name":"锌","range":"(5,0 - 10000) μg/l"},{"name":"总磷","range":"(50 - 100000) μg/l"},{"name":"铝","range":"(10 - 2000) μg/l"},{"name":"镉","range":"(0,10 - 2000) μg/l"},{"name":"钴","range":"(0,10 - 2000) μg/l"},{"name":"锰","range":"(1,0 - 2000) μg/l"},{"name":"铜","range":"(1,0 - 2000) μg/l"},{"name":"钼","range":"(1,0 - 2000) μg/l"},{"name":"镍","range":"(1,0 - 2000) μg/l"},{"name":"铅","range":"(1,0 - 2000) μg/l"},{"name":"汞","range":"(0,10 - 100) μg/l"},{"name":"硒","range":"(1,0 - 2000) μg/l"},{"name":"银","range":"(1,0 - 2000) μg/l"},{"name":"铊","range":"(1,0 - 2000) μg/l"},{"name":"钛","range":"(1,0 - 2000) μg/l"},{"name":"钒","range":"(1,0 - 2000) μg/l"},{"name":"铀","range":"(0,10 - 2000) μg/l"},{"name":"铁","range":"(10 - 10000) μg/l"}],"search_zh":"污水 元素浓度 电感耦合等离子体质谱法（ICP-MS） 锑 砷 钡 铍 硼 铬 锡 锌 总磷 铝 镉 钴 锰 铜 钼 镍 铅 汞 硒 银 铊 钛 钒 铀 铁 PN-EN ISO 17294-2:2024-04","technique_zh":"电感耦合等离子体质谱法（ICP-MS）","test_object_zh":"污水"},{"_id":"6a5dc9bcf1c10c8ce825e235","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology":"Stężenie anionów","methodology_en":"Anion concentrations","parameters":[{"name":"azotany","range":"(0,50 - 50) mg/l"},{"name":"chlorki","range":"(2,0 - 400) mg/l"},{"name":"fluorki","range":"(0,20 - 10) mg/l"},{"name":"siarczany","range":"(4,0 - 400) mg/l"}],"parameters_en":[{"name":"nitrates","range":"(0,50 - 50) mg/l"},{"name":"chlorides","range":"(2,0 - 400) mg/l"},{"name":"fluorides","range":"(0,20 - 10) mg/l"},{"name":"sulfates","range":"(4,0 - 400) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"technique_en":"Ion chromatography with conductometric detection (IC-CD)","computed":[],"computed_en":[],"activity":"Stężenie anionów\nZakres:\nazotany (0,50 - 50) mg/l\nchlorki (2,0 - 400) mg/l\nfluorki (0,20 - 10) mg/l\nsiarczany (4,0 - 400) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie anionów\nZakres:\nazotany (0,50 - 50) mg/l\nchlorki (2,0 - 400) mg/l\nfluorki (0,20 - 10) mg/l\nsiarczany (4,0 - 400) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Woda, Woda do spozycia przez ludzi, Scieki Stezenie anionow\nZakres:\nazotany (0,50 - 50) mg/l\nchlorki (2,0 - 400) mg/l\nfluorki (0,20 - 10) mg/l\nsiarczany (4,0 - 400) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":57,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption, Wastewater Anion concentrations Ion chromatography with conductometric detection (IC-CD) nitrates chlorides fluorides sulfates PN-EN ISO 10304-1:2009+AC:2012","methodology_zh":"阴离子浓度","search_zh":"水、生活饮用水、废水 阴离子浓度 离子色谱-电导检测法（IC-CD） 硝酸盐 氯化物 氟化物 硫酸盐 PN-EN ISO 10304-1:2009+AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水、生活饮用水、废水","parameters_zh":[{"name":"硝酸盐","range":"(0,50 - 50) mg/l"},{"name":"氯化物","range":"(2,0 - 400) mg/l"},{"name":"氟化物","range":"(0,20 - 10) mg/l"},{"name":"硫酸盐","range":"(4,0 - 400) mg/l"}]},{"_id":"6a5dc9bcf1c10c8ce825e236","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Liczba progowa smaku (TFN)","methodology_en":"Taste threshold number (TFN)","parameters":[{"name":"Zakres","range":"(1 - 8) TFN"}],"parameters_en":[{"name":"Range","range":"(1 - 8) TFN"}],"technique":"Metoda pełna parzysta, wybór niewymuszony","techniques":["Metoda pełna parzysta, wybór niewymuszony"],"technique_en":"Full paired method, non-forced choice","computed":[],"computed_en":[],"activity":"Liczba progowa smaku (TFN)\nZakres (1 - 8) TFN\nMetoda pełna parzysta, wybór niewymuszony","reference":"PN-EN 1622: 2006","norm_bases":["PN-EN 1622: 2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Liczba progowa smaku (TFN)\nZakres (1 - 8) TFN\nMetoda pełna parzysta, wybór niewymuszony PN-EN 1622: 2006 Woda do spozycia przez ludzi Liczba progowa smaku (TFN)\nZakres (1 - 8) TFN\nMetoda pelna parzysta, wybor niewymuszony PN-EN 1622: 2006","categories":["water"],"row_index":58,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Taste threshold number (TFN) Full paired method, non-forced choice Range PN-EN 1622: 2006","parameters_zh":[{"name":"范围","range":"(1 - 8) TFN"}],"search_zh":"生活饮用水 味阈值（TFN） 完全法、成对法、非强制选择 范围 PN-EN 1622: 2006","test_object_zh":"生活饮用水","methodology_zh":"味阈值（TFN）","technique_zh":"完全法、成对法、非强制选择"},{"_id":"6a5dc9bcf1c10c8ce825e237","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Liczba progowa smaku (TFN)","methodology_en":"Taste threshold number (TFN)","parameters":[{"name":"Zakres","range":"1"}],"parameters_en":[{"name":"Range","range":"1"}],"technique":"Metoda uproszczona, parzysta, wybór niewymuszony","techniques":["Metoda uproszczona, parzysta, wybór niewymuszony"],"technique_en":"Simplified method, paired, non-forced choice","computed":[],"computed_en":[],"activity":"Liczba progowa smaku (TFN)\nZakres 1\nMetoda uproszczona, parzysta, wybór niewymuszony","reference":"PN-EN 1622: 2006","norm_bases":["PN-EN 1622: 2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Liczba progowa smaku (TFN)\nZakres 1\nMetoda uproszczona, parzysta, wybór niewymuszony PN-EN 1622: 2006 Woda do spozycia przez ludzi Liczba progowa smaku (TFN)\nZakres 1\nMetoda uproszczona, parzysta, wybor niewymuszony PN-EN 1622: 2006","categories":["water"],"row_index":59,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Taste threshold number (TFN) Simplified method, paired, non-forced choice Range PN-EN 1622: 2006","parameters_zh":[{"name":"范围","range":"1"}],"search_zh":"生活饮用水 味阈值（TFN） 简化法，成对，非强制选择 范围 PN-EN 1622: 2006","test_object_zh":"生活饮用水","technique_zh":"简化法，成对，非强制选择","methodology_zh":"味阈值（TFN）"},{"_id":"6a5dc9bcf1c10c8ce825e238","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Liczba progowa zapachu (TON)","methodology_en":"Odour threshold number (TON)","parameters":[{"name":"Zakres","range":"(1 - 128) TON"}],"parameters_en":[{"name":"Range","range":"(1 - 128) TON"}],"technique":"Metoda pełna parzysta, wybór niewymuszony","techniques":["Metoda pełna parzysta, wybór niewymuszony"],"technique_en":"Full paired method, non-forced choice","computed":[],"computed_en":[],"activity":"Liczba progowa zapachu (TON)\nZakres (1 - 128) TON\nMetoda pełna parzysta, wybór niewymuszony","reference":"PN-EN 1622: 2006","norm_bases":["PN-EN 1622: 2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Liczba progowa zapachu (TON)\nZakres (1 - 128) TON\nMetoda pełna parzysta, wybór niewymuszony PN-EN 1622: 2006 Woda, Woda do spozycia przez ludzi Liczba progowa zapachu (TON)\nZakres (1 - 128) TON\nMetoda pelna parzysta, wybor niewymuszony PN-EN 1622: 2006","categories":["water"],"row_index":60,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Odour threshold number (TON) Full paired method, non-forced choice Range PN-EN 1622: 2006","parameters_zh":[{"name":"范围","range":"(1 - 128) TON"}],"search_zh":"水、生活饮用水 嗅阈值（TON） 完全法、成对法、非强制选择 范围 PN-EN 1622: 2006","test_object_zh":"水、生活饮用水","methodology_zh":"嗅阈值（TON）","technique_zh":"完全法、成对法、非强制选择"},{"_id":"6a5dc9bcf1c10c8ce825e239","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Liczba progowa zapachu (TON)","methodology_en":"Odour threshold number (TON)","parameters":[{"name":"Zakres","range":"1"}],"parameters_en":[{"name":"Range","range":"1"}],"technique":"Metoda uproszczona, parzysta, wybór niewymuszony","techniques":["Metoda uproszczona, parzysta, wybór niewymuszony"],"technique_en":"Simplified method, paired, non-forced choice","computed":[],"computed_en":[],"activity":"Liczba progowa zapachu (TON)\nZakres 1\nMetoda uproszczona, parzysta, wybór niewymuszony","reference":"PN-EN 1622: 2006","norm_bases":["PN-EN 1622: 2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Liczba progowa zapachu (TON)\nZakres 1\nMetoda uproszczona, parzysta, wybór niewymuszony PN-EN 1622: 2006 Woda, Woda do spozycia przez ludzi Liczba progowa zapachu (TON)\nZakres 1\nMetoda uproszczona, parzysta, wybor niewymuszony PN-EN 1622: 2006","categories":["water"],"row_index":61,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Odour threshold number (TON) Simplified method, paired, non-forced choice Range PN-EN 1622: 2006","parameters_zh":[{"name":"范围","range":"1"}],"search_zh":"水、生活饮用水 嗅阈值（TON） 简化法，成对，非强制选择 范围 PN-EN 1622: 2006","test_object_zh":"水、生活饮用水","technique_zh":"简化法，成对，非强制选择","methodology_zh":"嗅阈值（TON）"},{"_id":"6a5dc9bcf1c10c8ce825e23a","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Ogólna liczba mikroorganizmów w temp. 36°C","methodology_en":"Total viable count at 36°C","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"technique_en":"Plate method (pour plate)","computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w temp. 36°C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w temp. 36°C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda, Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w temp. 36°C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":62,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Total viable count at 36°C Plate method (pour plate) PN-EN ISO 6222:2004","search_zh":"水、生活饮用水 36°C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水、生活饮用水","methodology_zh":"36°C 微生物总数"},{"_id":"6a5dc9bcf1c10c8ce825e23b","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Ogólna liczba mikroorganizmów w temp. 22°C","methodology_en":"Total viable count at 22°C","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"technique_en":"Plate method (pour plate)","computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w temp. 22°C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w temp. 22°C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda, Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w temp. 22°C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":63,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Total viable count at 22°C Plate method (pour plate) PN-EN ISO 6222:2004","methodology_zh":"22°C 微生物总数","search_zh":"水、生活饮用水 22°C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9bcf1c10c8ce825e23c","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Liczba Escherichia coli","methodology_en":"Escherichia coli count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 + A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 + A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 + A1:2017-04 Woda, Woda do spozycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 + A1:2017-04","categories":["water","microbiology"],"row_index":64,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 + A1:2017-04","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"水、生活饮用水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PN-EN ISO 9308-1:2014-12 + A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9bcf1c10c8ce825e23d","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Liczba bakterii grupy coli","methodology_en":"Coliform bacteria count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 + A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 + A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 + A1:2017-04 Woda, Woda do spozycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 + A1:2017-04","categories":["water","microbiology"],"row_index":65,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 + A1:2017-04","methodology_zh":"大肠菌群计数","search_zh":"水、生活饮用水 大肠菌群计数 膜过滤法 PN-EN ISO 9308-1:2014-12 + A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9bcf1c10c8ce825e23e","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Liczba enterokoków kałowych","methodology_en":"Intestinal enterococci count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba enterokoków kałowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Liczba enterokoków kałowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda, Woda do spozycia przez ludzi Liczba enterokokow kalowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":66,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004","methodology_zh":"粪肠球菌计数","search_zh":"水、生活饮用水 粪肠球菌计数 膜过滤法 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9bcf1c10c8ce825e23f","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Liczba Pseudomonas aeruginosa","methodology_en":"Pseudomonas aeruginosa count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009 Woda, Woda do spozycia przez ludzi Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water"],"row_index":67,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009","methodology_zh":"铜绿假单胞菌计数","search_zh":"水、生活饮用水 铜绿假单胞菌计数 膜过滤法 PN-EN ISO 16266:2009","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9bcf1c10c8ce825e240","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Najbardziej prawdopodobna liczba, Escherichia coli","methodology_en":"Most probable number, Escherichia coli","parameters":[],"parameters_en":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"technique_en":"MPN method","computed":[],"computed_en":[],"activity":"Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda NPL","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda NPL PN-EN ISO 9308-2:2014-06 Woda, Woda do spozycia przez ludzi Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda NPL PN-EN ISO 9308-2:2014-06","categories":["water","microbiology"],"row_index":68,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Most probable number, Escherichia coli MPN method PN-EN ISO 9308-2:2014-06","methodology_zh":"大肠埃希氏菌（Escherichia coli）最可能数（MPN）","search_zh":"水、生活饮用水 大肠埃希氏菌（Escherichia coli）最可能数（MPN） 最可能数法（MPN） PN-EN ISO 9308-2:2014-06","technique_zh":"最可能数法（MPN）","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9bcf1c10c8ce825e241","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Najbardziej prawdopodobna liczba bakterii grupy coli","methodology_en":"Most probable number of coliform bacteria","parameters":[],"parameters_en":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"technique_en":"MPN method","computed":[],"computed_en":[],"activity":"Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL PN-EN ISO 9308-2:2014-06 Woda, Woda do spozycia przez ludzi Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL PN-EN ISO 9308-2:2014-06","categories":["water","microbiology"],"row_index":69,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Most probable number of coliform bacteria MPN method PN-EN ISO 9308-2:2014-06","methodology_zh":"大肠菌群最可能数（MPN）","search_zh":"水、生活饮用水 大肠菌群最可能数（MPN） 最可能数法（MPN） PN-EN ISO 9308-2:2014-06","technique_zh":"最可能数法（MPN）","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9bcf1c10c8ce825e242","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Odpady kod: 19 01 14","test_object_en":"Waste code: 19 01 14","methodology":"Zawartość pierwiastków: antymon (1,0 - 1000) mg/kg chrom (1,0 - 5000) mg/kg cynk (1,0 - 10000) mg/kg fosfor (5,0 - 200000) mg/kg kadm (1,0 - 100) mg/kg miedź (1,0 - 4000) mg/kg nikiel (1,0 - 1000) mg/kg ołów (1,0 - 3000) mg/kg rtęć (0,10 - 50) mg/kg","methodology_en":"Content of elements: antimony (1,0 - 1000) mg/kg chromium (1,0 - 5000) mg/kg zinc (1,0 - 10000) mg/kg phosphorus (5,0 - 200000) mg/kg cadmium (1,0 - 100) mg/kg copper (1,0 - 4000) mg/kg nickel (1,0 - 1000) mg/kg lead (1,0 - 3000) mg/kg mercury (0,10 - 50) mg/kg","parameters":[],"parameters_en":[],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","computed":[],"computed_en":[],"activity":"Zawartość pierwiastków: antymon (1,0 - 1000) mg/kg chrom (1,0 - 5000) mg/kg cynk (1,0 - 10000) mg/kg fosfor (5,0 - 200000) mg/kg kadm (1,0 - 100) mg/kg miedź (1,0 - 4000) mg/kg nikiel (1,0 - 1000) mg/kg ołów (1,0 - 3000) mg/kg rtęć (0,10 - 50) mg/kg\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"PN-EN ISO 17294-2:2024-04 | PN-EN ISO 54321: 2021-07","norm_bases":["PN-EN ISO 17294-2:2024-04","PN-EN ISO 54321: 2021-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady kod: 19 01 14 Zawartość pierwiastków: antymon (1,0 - 1000) mg/kg chrom (1,0 - 5000) mg/kg cynk (1,0 - 10000) mg/kg fosfor (5,0 - 200000) mg/kg kadm (1,0 - 100) mg/kg miedź (1,0 - 4000) mg/kg nikiel (1,0 - 1000) mg/kg ołów (1,0 - 3000) mg/kg rtęć (0,10 - 50) mg/kg\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) PN-EN ISO 17294-2:2024-04 | PN-EN ISO 54321: 2021-07 Odpady kod: 19 01 14 Zawartosc pierwiastkow: antymon (1,0 - 1000) mg/kg chrom (1,0 - 5000) mg/kg cynk (1,0 - 10000) mg/kg fosfor (5,0 - 200000) mg/kg kadm (1,0 - 100) mg/kg miedz (1,0 - 4000) mg/kg nikiel (1,0 - 1000) mg/kg olow (1,0 - 3000) mg/kg rtec (0,10 - 50) mg/kg\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) PN-EN ISO 17294-2:2024-04 | PN-EN ISO 54321: 2021-07","categories":["environment","materials"],"row_index":70,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste code: 19 01 14 Content of elements: antimony (1,0 - 1000) mg/kg chromium (1,0 - 5000) mg/kg zinc (1,0 - 10000) mg/kg phosphorus (5,0 - 200000) mg/kg cadmium (1,0 - 100) mg/kg copper (1,0 - 4000) mg/kg nickel (1,0 - 1000) mg/kg lead (1,0 - 3000) mg/kg mercury (0,10 - 50) mg/kg Inductively coupled plasma mass spectrometry (ICP-MS) PN-EN ISO 17294-2:2024-04 | PN-EN ISO 54321: 2021-07","search_zh":"电感耦合等离子体质谱法（ICP-MS） PN-EN ISO 17294-2:2024-04 | PN-EN ISO 54321: 2021-07","technique_zh":"电感耦合等离子体质谱法（ICP-MS）"},{"_id":"6a5dc9bcf1c10c8ce825e243","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Zawartość pierwiastków: miedź (1,0 - 4000) mg/kg cynk (1,0 - 10000) mg/kg ołów (1,0 - 3000) mg/kg nikiel (1,0 - 1000) mg/kg kadm (1,0 - 100) mg/kg chrom (1,0 - 5000) mg/kg rtęć (0,10 - 50) mg/kg wapń (25 - 200000) mg/kg magnez (25 - 200000) mg/kg fosfor (5,0 - 200000 ) mg/kg","methodology_en":"Content of elements: copper (1,0 - 4000) mg/kg zinc (1,0 - 10000) mg/kg lead (1,0 - 3000) mg/kg nickel (1,0 - 1000) mg/kg cadmium (1,0 - 100) mg/kg chromium (1,0 - 5000) mg/kg mercury (0,10 - 50) mg/kg calcium (25 - 200000) mg/kg magnesium (25 - 200000) mg/kg phosphorus (5,0 - 200000 ) mg/kg","parameters":[],"parameters_en":[],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","computed":[],"computed_en":[],"activity":"Zawartość pierwiastków: miedź (1,0 - 4000) mg/kg cynk (1,0 - 10000) mg/kg ołów (1,0 - 3000) mg/kg nikiel (1,0 - 1000) mg/kg kadm (1,0 - 100) mg/kg chrom (1,0 - 5000) mg/kg rtęć (0,10 - 50) mg/kg wapń (25 - 200000) mg/kg magnez (25 - 200000) mg/kg fosfor (5,0 - 200000 ) mg/kg\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"PN-EN ISO 17294-2:2024-04 | PN-EN ISO 54321: 2021-07","norm_bases":["PN-EN ISO 17294-2:2024-04","PN-EN ISO 54321: 2021-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Zawartość pierwiastków: miedź (1,0 - 4000) mg/kg cynk (1,0 - 10000) mg/kg ołów (1,0 - 3000) mg/kg nikiel (1,0 - 1000) mg/kg kadm (1,0 - 100) mg/kg chrom (1,0 - 5000) mg/kg rtęć (0,10 - 50) mg/kg wapń (25 - 200000) mg/kg magnez (25 - 200000) mg/kg fosfor (5,0 - 200000 ) mg/kg\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) PN-EN ISO 17294-2:2024-04 | PN-EN ISO 54321: 2021-07 Osady sciekowe Zawartosc pierwiastkow: miedz (1,0 - 4000) mg/kg cynk (1,0 - 10000) mg/kg olow (1,0 - 3000) mg/kg nikiel (1,0 - 1000) mg/kg kadm (1,0 - 100) mg/kg chrom (1,0 - 5000) mg/kg rtec (0,10 - 50) mg/kg wapn (25 - 200000) mg/kg magnez (25 - 200000) mg/kg fosfor (5,0 - 200000 ) mg/kg\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) PN-EN ISO 17294-2:2024-04 | PN-EN ISO 54321: 2021-07","categories":["water","materials"],"row_index":71,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge Content of elements: copper (1,0 - 4000) mg/kg zinc (1,0 - 10000) mg/kg lead (1,0 - 3000) mg/kg nickel (1,0 - 1000) mg/kg cadmium (1,0 - 100) mg/kg chromium (1,0 - 5000) mg/kg mercury (0,10 - 50) mg/kg calcium (25 - 200000) mg/kg magnesium (25 - 200000) mg/kg phosphorus (5,0 - 200000 ) mg/kg Inductively coupled plasma mass spectrometry (ICP-MS) PN-EN ISO 17294-2:2024-04 | PN-EN ISO 54321: 2021-07","search_zh":"污泥 电感耦合等离子体质谱法（ICP-MS） PN-EN ISO 17294-2:2024-04 | PN-EN ISO 54321: 2021-07","technique_zh":"电感耦合等离子体质谱法（ICP-MS）","test_object_zh":"污泥"},{"_id":"6a5dc9bcf1c10c8ce825e244","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Zawartość suchej masy / zawartość wody","methodology_en":"Dry matter content / water content","parameters":[{"name":"Zakres","range":"(1,0 - 99,0) %"}],"parameters_en":[{"name":"Range","range":"(1,0 - 99,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość suchej masy / zawartość wody\nZakres (1,0 - 99,0) %\nMetoda wagowa","reference":"PN-EN 15934:2013-02 (Metoda A)","norm_bases":["PN-EN 15934:2013-02 (Metoda A)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Zawartość suchej masy / zawartość wody\nZakres (1,0 - 99,0) %\nMetoda wagowa PN-EN 15934:2013-02 (Metoda A) Osady sciekowe Zawartosc suchej masy / zawartosc wody\nZakres (1,0 - 99,0) %\nMetoda wagowa PN-EN 15934:2013-02 (Metoda A)","categories":["water"],"row_index":72,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge Dry matter content / water content Gravimetric method Range PN-EN 15934:2013-02 (Metoda A)","parameters_zh":[{"name":"范围","range":"(1,0 - 99,0) %"}],"search_zh":"污泥 干物质含量/水分含量 重量法 范围 PN-EN 15934:2013-02 (Metoda A)","technique_zh":"重量法","test_object_zh":"污泥","methodology_zh":"干物质含量/水分含量"},{"_id":"6a5dc9bcf1c10c8ce825e245","lab_id":"69ad52a3de79e566650fb38a","country":"PL","accr_number":"AB 697","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Straty przy prażeniu suchej masy (LOI) / substancje organiczne","methodology_en":"Loss on ignition of dry matter (LOI) / organic matter","parameters":[{"name":"Zakres","range":"(0,5 - 99,5) %"}],"parameters_en":[{"name":"Range","range":"(0,5 - 99,5) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Straty przy prażeniu suchej masy (LOI) / substancje organiczne\nZakres (0,5 - 99,5) %\nMetoda wagowa","reference":"PN-EN 15935:2022-01","norm_bases":["PN-EN 15935:2022-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Straty przy prażeniu suchej masy (LOI) / substancje organiczne\nZakres (0,5 - 99,5) %\nMetoda wagowa PN-EN 15935:2022-01 Osady sciekowe Straty przy prazeniu suchej masy (LOI) / substancje organiczne\nZakres (0,5 - 99,5) %\nMetoda wagowa PN-EN 15935:2022-01","categories":["water"],"row_index":73,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge Loss on ignition of dry matter (LOI) / organic matter Gravimetric method Range PN-EN 15935:2022-01","parameters_zh":[{"name":"范围","range":"(0,5 - 99,5) %"}],"search_zh":"污泥 重量法 范围 PN-EN 15935:2022-01","technique_zh":"重量法","test_object_zh":"污泥"}],"has_pdf":true}