{"lab":{"_id":"69ad52a3de79e566650fb380","accr_number":"AB 688","country":"PL","accr_body":"PCA","address":"ul. Promienna 51, 43-603 Jaworzno, DEPARTAMENT ANALIZ CHEMICZNYCH, ul. Promienna 51","categories":["petro","environment","water","materials","construction"],"city":"Jaworzno","imported_at":"2026-03-08T10:42:43.265Z","methods_count":263,"name":"TAURON WYTWARZANIE SPÓŁKA AKCYJNA","parse_status":"parsed","parse_version":3,"pdf_files":["AB_688.pdf"],"scope_summary":"","search_text":"tauron wytwarzanie spółka akcyjna ul. promienna 51, 43-603 jaworzno, departament analiz chemicznych, ul. promienna 51 water pharma electronics other materials petro automotive food environment construction","status":"active","updated_at":"2026-03-08T14:51:35.521Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-17T21:17:11.724Z","location":{"type":"Point","coordinates":[19.2717,50.2056]},"email_confidence":"high","email_mx":true,"email_source":"https://www.pca.gov.pl/akredytowane-podmioty/akredytacje-aktywne/laboratoria-badawcze/AB%20688,podmiot.html","fields_of_testing":[{"codes":"C/10/P; C/28/P; C/30/P","pl":"Badania chemiczne i pobieranie próbek i paliw stałych, wód, ścieków","en":"Chemical tests and sampling of solid fuels, water, sewage"},{"codes":"C/4; C/5; C/10; C/32","pl":"Badania chemiczne wyrobów chemicznych, materiałów budowlanych, paliw ciekłych, odpadów","en":"Chemical tests and samplinaag of chemical products, building materials, liquid fuels, wastes"},{"codes":"N/10/P; N/28/P; N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek paliw stałych, wód, ścieków","en":"Physical properties and sampling of solid fuels, water, sewage"},{"codes":"N/4; N/5; N/32","pl":"Badania właściwości fizycznych wyrobów chemicznych, materiałów budowlanych, odpadów","en":"Physical properties chemical products, building materials, wastes"}],"issue":{"no":"29","date":"18.05.2026"},"parse_date":"2026-08-17T21:17:11.724Z","parse_source":"agent-claude-code","map_coord":[50.206229,19.204367],"map_geo":"nominatim-street","lab_locations":[{"name":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","address":"ul. Promienna 51, 43-603 Jaworzno","city":"Jaworzno","postal":"43-603"},{"name":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","address":"ul. Energetyków 15, 43-603 Jaworzno","city":"Jaworzno","postal":"43-603"},{"name":"Oddział Analiz Chemicznych w Elektrowni Łaziska","address":"ul. Wyzwolenia 30, 43-170 Łaziska Górne","city":"Łaziska Górne","postal":"43-170"},{"name":"Oddział Analiz Chemicznych w Elektrowni Łagisza","address":"ul. Pokoju 14, 42-504 Będzin","city":"Będzin","postal":"42-504"},{"name":"Oddział Analiz Chemicznych w Elektrowni Siersza","address":"32-541 Trzebinia","city":"Trzebinia","postal":"32-541"},{"name":"Oddział Analiz Chemicznych w Elektrociepłowni Katowice","address":"ul. Siemianowicka 60, 40-301 Katowice","city":"Katowice","postal":"40-301"},{"name":"Oddział Analiz Chemicznych w Elektrociepłowni Tychy","address":"ul. Przemysłowa 47, 43-100 Tychy","city":"Tychy","postal":"43-100"},{"name":"Oddział Analiz Chemicznych w Elektrociepłowni Bielsko - Biała","address":"ul. Tuwima 2, 43-300 Bielsko - Biała","city":"Bielsko - Biała","postal":"43-300"},{"name":"Oddział Analiz Chemicznych w Elektrociepłowni Bielsko - Biała","address":"ul. Legionów 243A, 43-500 Czechowice - Dziedzice","city":"Czechowice - Dziedzice","postal":"43-500"},{"name":"Oddział Analiz Chemicznych w Zakładzie Górniczym Sobieski","address":"ul. Sulińskiego 2, 43-600 Jaworzno","city":"Jaworzno","postal":"43-600"},{"name":"Oddział Analiz Chemicznych w Zakładzie Górniczym Janina","address":"ul. Górnicza 23, 32-590 Libiąż","city":"Libiąż","postal":"32-590"},{"name":"Oddział Analiz Chemicznych w Zakładzie Górniczym Brzeszcze","address":"ul. Kościuszki 1, 32-620 Brzeszcze","city":"Brzeszcze","postal":"32-620"}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/aa50ac5950af1cf5a4c4d6f9d752652f/AB%20688.pdf","has_en":true,"category_counts":{"petro":94,"environment":73,"water":60,"materials":59,"construction":42,"other":8},"category_scores":{"petro":26.3,"environment":15.86,"water":10.71,"materials":10.36,"construction":5.25,"other":0.19},"has_zh":true},"methods":[{"_id":"6a837a57af14b9c0e7b1fd4d","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań fizycznych i chemicznych","parameters":[],"technique":"Metoda manualna","techniques":["Metoda manualna"],"computed":[],"activity":"Pobieranie próbek do badań fizycznych i chemicznych\nMetoda manualna","reference":"PN-ISO 5667-10:1997","norm_bases":["PN-ISO 5667-10:1997"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań fizycznych i chemicznych\nMetoda manualna PN-ISO 5667-10:1997 Scieki Pobieranie probek do badan fizycznych i chemicznych\nMetoda manualna PN-ISO 5667-10:1997","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for physical and chemical testing","search_en":"Wastewater Sampling for physical and chemical testing Manual method PN-ISO 5667-10:1997","technique_en":"Manual method","test_object_en":"Wastewater","methodology_zh":"物理与化学检测用样品采集","search_zh":"污水 物理与化学检测用样品采集 手工法 PN-ISO 5667-10:1997","test_object_zh":"污水","technique_zh":"手工法"},{"_id":"6a837a57af14b9c0e7b1fd4e","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Scieki, woda pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"search_en":"Wastewater, water pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Wastewater, water","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"废水、水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"废水、水"},{"_id":"6a837a57af14b9c0e7b1fd4f","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(0,001– 200,0) mS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (0,001– 200,0) mS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Przewodność elektryczna właściwa\nZakres (0,001– 200,0) mS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Scieki, woda Przewodnosc elektryczna wlasciwa\nZakres (0,001– 200,0) mS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(0,001– 200,0) mS/cm"}],"search_en":"Wastewater, water Electrical conductivity Conductometric method Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Wastewater, water","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(0,001– 200,0) mS/cm"}],"search_zh":"废水、水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"废水、水"},{"_id":"6a837a57af14b9c0e7b1fd50","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Twardość ogólna Sumaryczna zawartość wapnia i magnezu","parameters":[{"name":"Zakres","range":"(5 – 6200) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Twardość ogólna Sumaryczna zawartość wapnia i magnezu\nZakres (5 – 6200) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Twardość ogólna Sumaryczna zawartość wapnia i magnezu\nZakres (5 – 6200) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999 Scieki, woda Twardosc ogolna Sumaryczna zawartosc wapnia i magnezu\nZakres (5 – 6200) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total hardness Total content of calcium and magnesium","parameters_en":[{"name":"Range","range":"(5 – 6200) mg/l CaCO3"}],"search_en":"Wastewater, water Total hardness Total content of calcium and magnesium Titrimetric method Range PN-ISO 6059:1999","technique_en":"Titrimetric method","test_object_en":"Wastewater, water","parameters_zh":[{"name":"范围","range":"(5 – 6200) mg/l CaCO3"}],"search_zh":"废水、水 滴定法 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"废水、水"},{"_id":"6a837a57af14b9c0e7b1fd51","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Zasadowość ogólna i zasadowość wobec fenoloftaleiny","parameters":[{"name":"Zakres","range":"(0,05 – 20) mmol/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zasadowość ogólna i zasadowość wobec fenoloftaleiny\nZakres (0,05 – 20) mmol/l\nMetoda miareczkowa","reference":"PN-EN ISO 9963-1:2001+Ap1:2004","norm_bases":["PN-EN ISO 9963-1:2001+Ap1:2004"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Zasadowość ogólna i zasadowość wobec fenoloftaleiny\nZakres (0,05 – 20) mmol/l\nMetoda miareczkowa PN-EN ISO 9963-1:2001+Ap1:2004 Scieki, woda Zasadowosc ogolna i zasadowosc wobec fenoloftaleiny\nZakres (0,05 – 20) mmol/l\nMetoda miareczkowa PN-EN ISO 9963-1:2001+Ap1:2004","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total alkalinity and phenolphthalein alkalinity","parameters_en":[{"name":"Range","range":"(0,05 – 20) mmol/l"}],"search_en":"Wastewater, water Total alkalinity and phenolphthalein alkalinity Titrimetric method Range PN-EN ISO 9963-1:2001+Ap1:2004","technique_en":"Titrimetric method","test_object_en":"Wastewater, water","parameters_zh":[{"name":"范围","range":"(0,05 – 20) mmol/l"}],"search_zh":"废水、水 总碱度与酚酞碱度 滴定法 范围 PN-EN ISO 9963-1:2001+Ap1:2004","technique_zh":"滴定法","test_object_zh":"废水、水","methodology_zh":"总碱度与酚酞碱度"},{"_id":"6a837a57af14b9c0e7b1fd52","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Stężenie krzemionki zdysocjowanej","parameters":[{"name":"Zakres","range":"(0,005 – 10,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie krzemionki zdysocjowanej\nZakres (0,005 – 10,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-71/C-04567.03","norm_bases":["PN-71/C-04567.03"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Stężenie krzemionki zdysocjowanej\nZakres (0,005 – 10,0) mg/l\nMetoda spektrofotometryczna PN-71/C-04567.03 Scieki, woda Stezenie krzemionki zdysocjowanej\nZakres (0,005 – 10,0) mg/l\nMetoda spektrofotometryczna PN-71/C-04567.03","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissociated silica concentration","parameters_en":[{"name":"Range","range":"(0,005 – 10,0) mg/l"}],"search_en":"Wastewater, water Dissociated silica concentration Spectrophotometric method Range PN-71/C-04567.03","technique_en":"Spectrophotometric method","test_object_en":"Wastewater, water","parameters_zh":[{"name":"范围","range":"(0,005 – 10,0) mg/l"}],"search_zh":"废水、水 解离二氧化硅浓度 分光光度法 范围 PN-71/C-04567.03","technique_zh":"分光光度法","test_object_zh":"废水、水","methodology_zh":"解离二氧化硅浓度"},{"_id":"6a837a57af14b9c0e7b1fd53","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5 – 26000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5 – 26000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Stężenie chlorków\nZakres (5 – 26000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Scieki, woda Stezenie chlorkow\nZakres (5 – 26000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5 – 26000) mg/l"}],"search_en":"Wastewater, water Chloride concentration Titrimetric method Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Wastewater, water","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5 – 26000) mg/l"}],"search_zh":"废水、水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"废水、水"},{"_id":"6a837a57af14b9c0e7b1fd54","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Stężenie żelaza","parameters":[{"name":"Zakres","range":"(0,010 – 15,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza\nZakres (0,010 – 15,0) mg/l\nMetoda spektrofotometryczna","reference":"PN ISO 6332:2001+Ap1:2016-06 z wyłączeniem pkt. 7.3.","norm_bases":["PN ISO 6332:2001+Ap1:2016-06 z wyłączeniem pkt. 7.3."],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Stężenie żelaza\nZakres (0,010 – 15,0) mg/l\nMetoda spektrofotometryczna PN ISO 6332:2001+Ap1:2016-06 z wyłączeniem pkt. 7.3. Scieki, woda Stezenie zelaza\nZakres (0,010 – 15,0) mg/l\nMetoda spektrofotometryczna PN ISO 6332:2001+Ap1:2016-06 z wylaczeniem pkt. 7.3.","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Iron concentration","parameters_en":[{"name":"Range","range":"(0,010 – 15,0) mg/l"}],"search_en":"Wastewater, water Iron concentration Spectrophotometric method Range PN ISO 6332:2001+Ap1:2016-06 z wyłączeniem pkt. 7.3.","technique_en":"Spectrophotometric method","test_object_en":"Wastewater, water","methodology_zh":"铁浓度","parameters_zh":[{"name":"范围","range":"(0,010 – 15,0) mg/l"}],"search_zh":"废水、水 铁浓度 分光光度法 范围 PN ISO 6332:2001+Ap1:2016-06 z wyłączeniem pkt. 7.3.","technique_zh":"分光光度法","test_object_zh":"废水、水"},{"_id":"6a837a57af14b9c0e7b1fd55","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0 – 2500) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 2500) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Zawiesiny ogólne\nZakres (2,0 – 2500) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Scieki, woda Zawiesiny ogolne\nZakres (2,0 – 2500) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2,0 – 2500) mg/l"}],"search_en":"Wastewater, water Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Wastewater, water","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 2500) mg/l"}],"search_zh":"废水、水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"废水、水"},{"_id":"6a837a57af14b9c0e7b1fd56","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Całkowite substancje rozpuszczone (TDS)","parameters":[{"name":"Zakres","range":"(20,0 – 15000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Całkowite substancje rozpuszczone (TDS)\nZakres (20,0 – 15000) mg/l\nMetoda wagowa","reference":"PN-EN 15216:2022-03","norm_bases":["PN-EN 15216:2022-03"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Całkowite substancje rozpuszczone (TDS)\nZakres (20,0 – 15000) mg/l\nMetoda wagowa PN-EN 15216:2022-03 Scieki, woda Calkowite substancje rozpuszczone (TDS)\nZakres (20,0 – 15000) mg/l\nMetoda wagowa PN-EN 15216:2022-03","categories":["water"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total dissolved solids (TDS)","parameters_en":[{"name":"Range","range":"(20,0 – 15000) mg/l"}],"search_en":"Wastewater, water Total dissolved solids (TDS) Gravimetric method Range PN-EN 15216:2022-03","technique_en":"Gravimetric method","test_object_en":"Wastewater, water","parameters_zh":[{"name":"范围","range":"(20,0 – 15000) mg/l"}],"search_zh":"废水、水 溶解性总固体（TDS） 重量法 范围 PN-EN 15216:2022-03","technique_zh":"重量法","test_object_zh":"废水、水","methodology_zh":"溶解性总固体（TDS）"},{"_id":"6a837a57af14b9c0e7b1fd57","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Stężenie ortofosofranów","parameters":[{"name":"Zakres","range":"(0,015 – 20,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie ortofosofranów\nZakres (0,015 – 20,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 pkt 4 Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 pkt 4 Ap1:2010+Ap2:2010"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Stężenie ortofosofranów\nZakres (0,015 – 20,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt 4 Ap1:2010+Ap2:2010 Scieki, woda Stezenie ortofosofranow\nZakres (0,015 – 20,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt 4 Ap1:2010+Ap2:2010","categories":["water"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Orthophosphate concentration","parameters_en":[{"name":"Range","range":"(0,015 – 20,0) mg/l"}],"search_en":"Wastewater, water Orthophosphate concentration Spectrophotometric method Range PN-EN ISO 6878:2006 pkt 4 Ap1:2010+Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Wastewater, water","parameters_zh":[{"name":"范围","range":"(0,015 – 20,0) mg/l"}],"search_zh":"废水、水 分光光度法 范围 PN-EN ISO 6878:2006 pkt 4 Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"废水、水"},{"_id":"6a837a57af14b9c0e7b1fd58","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,03 – 8,5) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,03 – 8,5) mg/l\nMetoda spektrofotometryczna","reference":"PN-C-04576-4:1994","norm_bases":["PN-C-04576-4:1994"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Stężenie azotu amonowego\nZakres (0,03 – 8,5) mg/l\nMetoda spektrofotometryczna PN-C-04576-4:1994 Scieki, woda Stezenie azotu amonowego\nZakres (0,03 – 8,5) mg/l\nMetoda spektrofotometryczna PN-C-04576-4:1994","categories":["water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,03 – 8,5) mg/l"}],"search_en":"Wastewater, water Ammonium nitrogen concentration Spectrophotometric method Range PN-C-04576-4:1994","technique_en":"Spectrophotometric method","test_object_en":"Wastewater, water","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,03 – 8,5) mg/l"}],"search_zh":"废水、水 氨氮浓度 分光光度法 范围 PN-C-04576-4:1994","technique_zh":"分光光度法","test_object_zh":"废水、水"},{"_id":"6a837a57af14b9c0e7b1fd59","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Stężenie jonu amonowego","parameters":[{"name":"Zakres","range":"(0,04 – 10,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie jonu amonowego\nZakres (0,04 – 10,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-C-04576-4:1994","norm_bases":["PN-C-04576-4:1994"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Stężenie jonu amonowego\nZakres (0,04 – 10,0) mg/l\nMetoda spektrofotometryczna PN-C-04576-4:1994 Scieki, woda Stezenie jonu amonowego\nZakres (0,04 – 10,0) mg/l\nMetoda spektrofotometryczna PN-C-04576-4:1994","categories":["water"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium ion concentration","parameters_en":[{"name":"Range","range":"(0,04 – 10,0) mg/l"}],"search_en":"Wastewater, water Ammonium ion concentration Spectrophotometric method Range PN-C-04576-4:1994","technique_en":"Spectrophotometric method","test_object_en":"Wastewater, water","methodology_zh":"铵离子浓度","parameters_zh":[{"name":"范围","range":"(0,04 – 10,0) mg/l"}],"search_zh":"废水、水 铵离子浓度 分光光度法 范围 PN-C-04576-4:1994","technique_zh":"分光光度法","test_object_zh":"废水、水"},{"_id":"6a837a57af14b9c0e7b1fd5a","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(10,0 – 1000) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie siarczanów\nZakres (10,0 – 1000) mg/l\nMetoda spektrofotometryczna","reference":"IB-DPA-02 wersja 06 z dnia 02-01-2026 r. | na podstawie testu kuwetowego HACH 8051","norm_bases":["IB-DPA-02 wersja 06 z dnia 02-01-2026 r.","na podstawie testu kuwetowego HACH 8051"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Stężenie siarczanów\nZakres (10,0 – 1000) mg/l\nMetoda spektrofotometryczna IB-DPA-02 wersja 06 z dnia 02-01-2026 r. | na podstawie testu kuwetowego HACH 8051 Scieki, woda Stezenie siarczanow\nZakres (10,0 – 1000) mg/l\nMetoda spektrofotometryczna IB-DPA-02 wersja 06 z dnia 02-01-2026 r. | na podstawie testu kuwetowego HACH 8051","categories":["water"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Range","range":"(10,0 – 1000) mg/l"}],"search_en":"Wastewater, water Sulfate concentration Spectrophotometric method Range IB-DPA-02 wersja 06 z dnia 02-01-2026 r. | na podstawie testu kuwetowego HACH 8051","technique_en":"Spectrophotometric method","test_object_en":"Wastewater, water","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(10,0 – 1000) mg/l"}],"search_zh":"废水、水 硫酸盐浓度 分光光度法 范围 IB-DPA-02 wersja 06 z dnia 02-01-2026 r. | na podstawie testu kuwetowego HACH 8051","technique_zh":"分光光度法","test_object_zh":"废水、水"},{"_id":"6a837a57af14b9c0e7b1fd5b","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Chemiczne zapotrzebowanie tlenu (ChZT-Cr)","parameters":[{"name":"Zakres","range":"(10 – 260) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu (ChZT-Cr)\nZakres (10 – 260) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Chemiczne zapotrzebowanie tlenu (ChZT-Cr)\nZakres (10 – 260) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Scieki, woda Chemiczne zapotrzebowanie tlenu (ChZT-Cr)\nZakres (10 – 260) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand (COD-Cr)","parameters_en":[{"name":"Range","range":"(10 – 260) mg/l O2"}],"search_en":"Wastewater, water Chemical oxygen demand (COD-Cr) Spectrophotometric method Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Wastewater, water","methodology_zh":"化学需氧量（ChZT-Cr / CODCr）","parameters_zh":[{"name":"范围","range":"(10 – 260) mg/l O2"}],"search_zh":"废水、水 化学需氧量（ChZT-Cr / CODCr） 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"废水、水"},{"_id":"6a837a57af14b9c0e7b1fd5c","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Stężenie metali","parameters":[{"name":"Pb","range":"(0,020 – 1,0) mg/l"},{"name":"Mo","range":"(0,008 – 1,0) mg/l"},{"name":"Cr","range":"(0,015 – 1,0) mg/l"},{"name":"Zn","range":"(0,007 – 5,0) mg/l"},{"name":"Cd","range":"(0,007 – 0,5) mg/l"},{"name":"Ni","range":"(0,008 – 1,0) mg/l"},{"name":"Co","range":"(0,008 – 0,5) mg/l"},{"name":"Mn","range":"(0,006 – 1,0) mg/l"},{"name":"V","range":"(0,007 – 0,5) mg/l"},{"name":"Cu","range":"(0,014 – 1,0) mg/l"},{"name":"Sr","range":"(0,019 – 2,0) mg/l"},{"name":"B","range":"(0,014 – 20,0) mg/l"},{"name":"Ba","range":"(0,010 – 2,0) mg/l"},{"name":"As","range":"(0,020 – 2,0) mg/l"},{"name":"Na","range":"(0,060 – 1000) mg/l"},{"name":"K","range":"(0,20 – 1000) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie metali\nZakres:\nPb (0,020 – 1,0) mg/l\nMo (0,008 – 1,0) mg/l\nCr (0,015 – 1,0) mg/l\nZn (0,007 – 5,0) mg/l\nCd (0,007 – 0,5) mg/l\nNi (0,008 – 1,0) mg/l\nCo (0,008 – 0,5) mg/l\nMn (0,006 – 1,0) mg/l\nV (0,007 – 0,5) mg/l\nCu (0,014 – 1,0) mg/l\nSr (0,019 – 2,0) mg/l\nB (0,014 – 20,0) mg/l\nBa (0,010 – 2,0) mg/l\nAs (0,020 – 2,0) mg/l\nNa (0,060 – 1000) mg/l\nK (0,20 – 1000) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Stężenie metali\nZakres:\nPb (0,020 – 1,0) mg/l\nMo (0,008 – 1,0) mg/l\nCr (0,015 – 1,0) mg/l\nZn (0,007 – 5,0) mg/l\nCd (0,007 – 0,5) mg/l\nNi (0,008 – 1,0) mg/l\nCo (0,008 – 0,5) mg/l\nMn (0,006 – 1,0) mg/l\nV (0,007 – 0,5) mg/l\nCu (0,014 – 1,0) mg/l\nSr (0,019 – 2,0) mg/l\nB (0,014 – 20,0) mg/l\nBa (0,010 – 2,0) mg/l\nAs (0,020 – 2,0) mg/l\nNa (0,060 – 1000) mg/l\nK (0,20 – 1000) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Scieki, woda Stezenie metali\nZakres:\nPb (0,020 – 1,0) mg/l\nMo (0,008 – 1,0) mg/l\nCr (0,015 – 1,0) mg/l\nZn (0,007 – 5,0) mg/l\nCd (0,007 – 0,5) mg/l\nNi (0,008 – 1,0) mg/l\nCo (0,008 – 0,5) mg/l\nMn (0,006 – 1,0) mg/l\nV (0,007 – 0,5) mg/l\nCu (0,014 – 1,0) mg/l\nSr (0,019 – 2,0) mg/l\nB (0,014 – 20,0) mg/l\nBa (0,010 – 2,0) mg/l\nAs (0,020 – 2,0) mg/l\nNa (0,060 – 1000) mg/l\nK (0,20 – 1000) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["water","materials"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Metal concentrations","parameters_en":[{"name":"Pb","range":"(0,020 – 1,0) mg/l"},{"name":"Mo","range":"(0,008 – 1,0) mg/l"},{"name":"Cr","range":"(0,015 – 1,0) mg/l"},{"name":"Zn","range":"(0,007 – 5,0) mg/l"},{"name":"Cd","range":"(0,007 – 0,5) mg/l"},{"name":"Ni","range":"(0,008 – 1,0) mg/l"},{"name":"Co","range":"(0,008 – 0,5) mg/l"},{"name":"Mn","range":"(0,006 – 1,0) mg/l"},{"name":"V","range":"(0,007 – 0,5) mg/l"},{"name":"Cu","range":"(0,014 – 1,0) mg/l"},{"name":"Sr","range":"(0,019 – 2,0) mg/l"},{"name":"B","range":"(0,014 – 20,0) mg/l"},{"name":"Ba","range":"(0,010 – 2,0) mg/l"},{"name":"As","range":"(0,020 – 2,0) mg/l"},{"name":"Na","range":"(0,060 – 1000) mg/l"},{"name":"K","range":"(0,20 – 1000) mg/l"}],"search_en":"Wastewater, water Metal concentrations Inductively coupled plasma optical emission spectrometry (ICP-OES) Pb Mo Cr Zn Cd Ni Co Mn V Cu Sr B Ba As Na K PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Wastewater, water","methodology_zh":"金属浓度","parameters_zh":[{"name":"Pb","range":"(0,020 – 1,0) mg/l"},{"name":"Mo","range":"(0,008 – 1,0) mg/l"},{"name":"Cr","range":"(0,015 – 1,0) mg/l"},{"name":"Zn","range":"(0,007 – 5,0) mg/l"},{"name":"Cd","range":"(0,007 – 0,5) mg/l"},{"name":"Ni","range":"(0,008 – 1,0) mg/l"},{"name":"Co","range":"(0,008 – 0,5) mg/l"},{"name":"Mn","range":"(0,006 – 1,0) mg/l"},{"name":"V","range":"(0,007 – 0,5) mg/l"},{"name":"Cu","range":"(0,014 – 1,0) mg/l"},{"name":"Sr","range":"(0,019 – 2,0) mg/l"},{"name":"B","range":"(0,014 – 20,0) mg/l"},{"name":"Ba","range":"(0,010 – 2,0) mg/l"},{"name":"As","range":"(0,020 – 2,0) mg/l"},{"name":"Na","range":"(0,060 – 1000) mg/l"},{"name":"K","range":"(0,20 – 1000) mg/l"}],"search_zh":"废水、水 金属浓度 电感耦合等离子体原子发射光谱法（ICP-OES） Pb Mo Cr Zn Cd Ni Co Mn V Cu Sr B Ba As Na K PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"废水、水"},{"_id":"6a837a57af14b9c0e7b1fd5d","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Stężenie rtęci","parameters":[{"name":"Zakres","range":"(0,060 - 150) μg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","techniques":["Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji"],"computed":[],"activity":"Stężenie rtęci\nZakres (0,060 - 150) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","reference":"IB-DPA-09 wersja 04 z dnia 02-01-2026 r.","norm_bases":["IB-DPA-09 wersja 04 z dnia 02-01-2026 r."],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Stężenie rtęci\nZakres (0,060 - 150) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji IB-DPA-09 wersja 04 z dnia 02-01-2026 r. Scieki, woda Stezenie rteci\nZakres (0,060 - 150) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z technika amalgamacji IB-DPA-09 wersja 04 z dnia 02-01-2026 r.","categories":["water"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury concentration","parameters_en":[{"name":"Range","range":"(0,060 - 150) μg/l"}],"search_en":"Wastewater, water Mercury concentration Atomic absorption spectrometry with amalgamation technique Range IB-DPA-09 wersja 04 z dnia 02-01-2026 r.","technique_en":"Atomic absorption spectrometry with amalgamation technique","test_object_en":"Wastewater, water","methodology_zh":"汞浓度","parameters_zh":[{"name":"范围","range":"(0,060 - 150) μg/l"}],"search_zh":"废水、水 汞浓度 原子吸收光谱法（汞齐化技术） 范围 IB-DPA-09 wersja 04 z dnia 02-01-2026 r.","technique_zh":"原子吸收光谱法（汞齐化技术）","test_object_zh":"废水、水"},{"_id":"6a837a57af14b9c0e7b1fd5e","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Stężenie anionów","parameters":[{"name":"Chlorki","range":"(0,05 - 18000) mg/l"},{"name":"Siarczany","range":"(0,05 - 6000) mg/l"},{"name":"Fosforany","range":"(0,10 – 30,00) mg/l"},{"name":"Fluorki","range":"(0,01 – 27,0) mg/l"},{"name":"Azotany","range":"(0,05 – 600) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie anionów\nZakres:\nChlorki (0,05 - 18000) mg/l\nSiarczany (0,05 - 6000) mg/l\nFosforany (0,10 – 30,00) mg/l\nFluorki (0,01 – 27,0) mg/l\nAzotany (0,05 – 600) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009 +AC:2012","norm_bases":["PN-EN ISO 10304-1:2009 +AC:2012"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Stężenie anionów\nZakres:\nChlorki (0,05 - 18000) mg/l\nSiarczany (0,05 - 6000) mg/l\nFosforany (0,10 – 30,00) mg/l\nFluorki (0,01 – 27,0) mg/l\nAzotany (0,05 – 600) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009 +AC:2012 Scieki, woda Stezenie anionow\nZakres:\nChlorki (0,05 - 18000) mg/l\nSiarczany (0,05 - 6000) mg/l\nFosforany (0,10 – 30,00) mg/l\nFluorki (0,01 – 27,0) mg/l\nAzotany (0,05 – 600) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009 +AC:2012","categories":["water"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Anion concentrations","parameters_en":[{"name":"Chlorides","range":"(0,05 - 18000) mg/l"},{"name":"Sulfates","range":"(0,05 - 6000) mg/l"},{"name":"Phosphates","range":"(0,10 – 30,00) mg/l"},{"name":"Fluorides","range":"(0,01 – 27,0) mg/l"},{"name":"Nitrates","range":"(0,05 – 600) mg/l"}],"search_en":"Wastewater, water Anion concentrations Ion chromatography with conductometric detection (IC-CD) Chlorides Sulfates Phosphates Fluorides Nitrates PN-EN ISO 10304-1:2009 +AC:2012","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Wastewater, water","methodology_zh":"阴离子浓度","parameters_zh":[{"name":"氯化物","range":"(0,05 - 18000) mg/l"},{"name":"硫酸盐","range":"(0,05 - 6000) mg/l"},{"name":"磷酸盐","range":"(0,10 – 30,00) mg/l"},{"name":"氟化物","range":"(0,01 – 27,0) mg/l"},{"name":"硝酸盐","range":"(0,05 – 600) mg/l"}],"search_zh":"废水、水 阴离子浓度 离子色谱-电导检测法（IC-CD） 氯化物 硫酸盐 磷酸盐 氟化物 硝酸盐 PN-EN ISO 10304-1:2009 +AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"废水、水"},{"_id":"6a837a57af14b9c0e7b1fd5f","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-G-04502:2014-11 pkt 5.3.1.2; 5.3.1.3; 5.3.3; 5.3.4; 5.3.6","norm_bases":["PN-G-04502:2014-11 pkt 5.3.1.2; 5.3.1.3; 5.3.3; 5.3.4; 5.3.6"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Pobieranie próbek do badań chemicznych i fizycznych PN-G-04502:2014-11 pkt 5.3.1.2; 5.3.1.3; 5.3.3; 5.3.4; 5.3.6 Paliwa stale: wegiel kamienny Pobieranie probek do badan chemicznych i fizycznych PN-G-04502:2014-11 pkt 5.3.1.2; 5.3.1.3; 5.3.3; 5.3.4; 5.3.6","categories":["petro"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Solid fuels: hard coal Sampling for chemical and physical testing PN-G-04502:2014-11 pkt 5.3.1.2; 5.3.1.3; 5.3.3; 5.3.4; 5.3.6","test_object_en":"Solid fuels: hard coal","methodology_zh":"化学与物理检测用样品采集","search_zh":"固体燃料：烟煤 化学与物理检测用样品采集 PN-G-04502:2014-11 pkt 5.3.1.2; 5.3.1.3; 5.3.3; 5.3.4; 5.3.6","test_object_zh":"固体燃料：烟煤"},{"_id":"6a837a57af14b9c0e7b1fd60","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wilgoci pierwszego stopnia (wilgoci przemijającej)","parameters":[{"name":"Zakres","range":"(0,5 – 39,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci pierwszego stopnia (wilgoci przemijającej)\nZakres (0,5 – 39,0) %\nMetoda wagowa","reference":"PN-ISO 589:2006 | PN-G-04611:2020-06","norm_bases":["PN-ISO 589:2006","PN-G-04611:2020-06"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci pierwszego stopnia (wilgoci przemijającej)\nZakres (0,5 – 39,0) %\nMetoda wagowa PN-ISO 589:2006 | PN-G-04611:2020-06 Paliwa stale: wegiel kamienny Zawartosc wilgoci pierwszego stopnia (wilgoci przemijajacej)\nZakres (0,5 – 39,0) %\nMetoda wagowa PN-ISO 589:2006 | PN-G-04611:2020-06","categories":["petro"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"First-stage moisture content (free moisture)","parameters_en":[{"name":"Range","range":"(0,5 – 39,0) %"}],"search_en":"Solid fuels: hard coal First-stage moisture content (free moisture) Gravimetric method Range PN-ISO 589:2006 | PN-G-04611:2020-06","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","parameters_zh":[{"name":"范围","range":"(0,5 – 39,0) %"}],"search_zh":"固体燃料：烟煤 第一阶段水分（外在水分）含量 重量法 范围 PN-ISO 589:2006 | PN-G-04611:2020-06","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤","methodology_zh":"第一阶段水分（外在水分）含量"},{"_id":"6a837a57af14b9c0e7b1fd61","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wilgoci całkowitej (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość wilgoci całkowitej (z obliczeń)","reference":"PN-ISO 589:2006, metoda A | PN-G-04611:2020-06","norm_bases":["PN-ISO 589:2006, metoda A","PN-G-04611:2020-06"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci całkowitej (z obliczeń) PN-ISO 589:2006, metoda A | PN-G-04611:2020-06 Paliwa stale: wegiel kamienny Zawartosc wilgoci calkowitej (z obliczen) PN-ISO 589:2006, metoda A | PN-G-04611:2020-06","categories":["petro"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total moisture content (calculated)","search_en":"Solid fuels: hard coal Total moisture content (calculated) PN-ISO 589:2006, metoda A | PN-G-04611:2020-06","test_object_en":"Solid fuels: hard coal","search_zh":"固体燃料：烟煤 全水分含量（计算值） PN-ISO 589:2006, metoda A | PN-G-04611:2020-06","test_object_zh":"固体燃料：烟煤","methodology_zh":"全水分含量（计算值）"},{"_id":"6a837a57af14b9c0e7b1fd62","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wilgoci w próbce analitycznej","parameters":[{"name":"Zakres","range":"(0,7 – 17,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (0,7 – 17,0) %\nMetoda wagowa","reference":"PN-ISO 11722:2009","norm_bases":["PN-ISO 11722:2009"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci w próbce analitycznej\nZakres (0,7 – 17,0) %\nMetoda wagowa PN-ISO 11722:2009 Paliwa stale: wegiel kamienny Zawartosc wilgoci w probce analitycznej\nZakres (0,7 – 17,0) %\nMetoda wagowa PN-ISO 11722:2009","categories":["petro"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Moisture content in the analytical sample","parameters_en":[{"name":"Range","range":"(0,7 – 17,0) %"}],"search_en":"Solid fuels: hard coal Moisture content in the analytical sample Gravimetric method Range PN-ISO 11722:2009","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(0,7 – 17,0) %"}],"search_zh":"固体燃料：烟煤 分析样品水分含量 重量法 范围 PN-ISO 11722:2009","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a837a57af14b9c0e7b1fd63","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wilgoci w próbce analitycznej","parameters":[{"name":"Zakres","range":"(0,7 – 17,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (0,7 – 17,0) %\nMetoda wagowa","reference":"PN-G-04611:2020-06","norm_bases":["PN-G-04611:2020-06"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci w próbce analitycznej\nZakres (0,7 – 17,0) %\nMetoda wagowa PN-G-04611:2020-06 Paliwa stale: wegiel kamienny Zawartosc wilgoci w probce analitycznej\nZakres (0,7 – 17,0) %\nMetoda wagowa PN-G-04611:2020-06","categories":["petro"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Moisture content in the analytical sample","parameters_en":[{"name":"Range","range":"(0,7 – 17,0) %"}],"search_en":"Solid fuels: hard coal Moisture content in the analytical sample Gravimetric method Range PN-G-04611:2020-06","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(0,7 – 17,0) %"}],"search_zh":"固体燃料：烟煤 分析样品水分含量 重量法 范围 PN-G-04611:2020-06","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a837a57af14b9c0e7b1fd64","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wilgoci w próbce analitycznej","parameters":[{"name":"Zakres","range":"(0,40 –17,00) %"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (0,40 –17,00) %\nMetoda termograwimetryczna (TGA)","reference":"PN-G-04560:1998","norm_bases":["PN-G-04560:1998"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci w próbce analitycznej\nZakres (0,40 –17,00) %\nMetoda termograwimetryczna (TGA) PN-G-04560:1998 Paliwa stale: wegiel kamienny Zawartosc wilgoci w probce analitycznej\nZakres (0,40 –17,00) %\nMetoda termograwimetryczna (TGA) PN-G-04560:1998","categories":["petro"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Moisture content in the analytical sample","parameters_en":[{"name":"Range","range":"(0,40 –17,00) %"}],"search_en":"Solid fuels: hard coal Moisture content in the analytical sample Thermogravimetric method (TGA) Range PN-G-04560:1998","technique_en":"Thermogravimetric method (TGA)","test_object_en":"Solid fuels: hard coal","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(0,40 –17,00) %"}],"search_zh":"固体燃料：烟煤 分析样品水分含量 热重法（TGA） 范围 PN-G-04560:1998","technique_zh":"热重法（TGA）","test_object_zh":"固体燃料：烟煤"},{"_id":"6a837a57af14b9c0e7b1fd65","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wilgoci całkowitej","parameters":[{"name":"Zakres","range":"(1,5 – 42,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci całkowitej\nZakres (1,5 – 42,0) %\nMetoda wagowa","reference":"PN-G-04611:2020-06","norm_bases":["PN-G-04611:2020-06"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci całkowitej\nZakres (1,5 – 42,0) %\nMetoda wagowa PN-G-04611:2020-06 Paliwa stale: wegiel kamienny Zawartosc wilgoci calkowitej\nZakres (1,5 – 42,0) %\nMetoda wagowa PN-G-04611:2020-06","categories":["petro"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total moisture content","parameters_en":[{"name":"Range","range":"(1,5 – 42,0) %"}],"search_en":"Solid fuels: hard coal Total moisture content Gravimetric method Range PN-G-04611:2020-06","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","methodology_zh":"全水分含量","parameters_zh":[{"name":"范围","range":"(1,5 – 42,0) %"}],"search_zh":"固体燃料：烟煤 全水分含量 重量法 范围 PN-G-04611:2020-06","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a837a57af14b9c0e7b1fd66","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wilgoci całkowitej","parameters":[{"name":"Zakres","range":"(1,5 – 42,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci całkowitej\nZakres (1,5 – 42,0) %\nMetoda wagowa","reference":"PN-ISO 589:2006 Metoda B1 i B2","norm_bases":["PN-ISO 589:2006 Metoda B1 i B2"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci całkowitej\nZakres (1,5 – 42,0) %\nMetoda wagowa PN-ISO 589:2006 Metoda B1 i B2 Paliwa stale: wegiel kamienny Zawartosc wilgoci calkowitej\nZakres (1,5 – 42,0) %\nMetoda wagowa PN-ISO 589:2006 Metoda B1 i B2","categories":["petro"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total moisture content","parameters_en":[{"name":"Range","range":"(1,5 – 42,0) %"}],"search_en":"Solid fuels: hard coal Total moisture content Gravimetric method Range PN-ISO 589:2006 Metoda B1 i B2","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","methodology_zh":"全水分含量","parameters_zh":[{"name":"范围","range":"(1,5 – 42,0) %"}],"search_zh":"固体燃料：烟煤 全水分含量 重量法 范围 PN-ISO 589:2006 Metoda B1 i B2","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a837a57af14b9c0e7b1fd67","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wilgoci drugiego stopnia (wilgoci pozostałej w próbce)","parameters":[{"name":"Zakres","range":"(0,7 – 15,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci drugiego stopnia (wilgoci pozostałej w próbce)\nZakres (0,7 – 15,0) %\nMetoda wagowa","reference":"PN-ISO 589:2006 Metoda A1 i A2","norm_bases":["PN-ISO 589:2006 Metoda A1 i A2"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci drugiego stopnia (wilgoci pozostałej w próbce)\nZakres (0,7 – 15,0) %\nMetoda wagowa PN-ISO 589:2006 Metoda A1 i A2 Paliwa stale: wegiel kamienny Zawartosc wilgoci drugiego stopnia (wilgoci pozostalej w probce)\nZakres (0,7 – 15,0) %\nMetoda wagowa PN-ISO 589:2006 Metoda A1 i A2","categories":["petro"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Second-stage moisture content (moisture remaining in the sample)","parameters_en":[{"name":"Range","range":"(0,7 – 15,0) %"}],"search_en":"Solid fuels: hard coal Second-stage moisture content (moisture remaining in the sample) Gravimetric method Range PN-ISO 589:2006 Metoda A1 i A2","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","parameters_zh":[{"name":"范围","range":"(0,7 – 15,0) %"}],"search_zh":"固体燃料：烟煤 第二阶段水分（样品残余水分）含量 重量法 范围 PN-ISO 589:2006 Metoda A1 i A2","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤","methodology_zh":"第二阶段水分（样品残余水分）含量"},{"_id":"6a837a57af14b9c0e7b1fd68","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość popiołu","parameters":[{"name":"Zakres","range":"(2,0 – 85,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość popiołu\nZakres (2,0 – 85,0) %\nMetoda wagowa","reference":"PN-ISO 1171:2002","norm_bases":["PN-ISO 1171:2002"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość popiołu\nZakres (2,0 – 85,0) %\nMetoda wagowa PN-ISO 1171:2002 Paliwa stale: wegiel kamienny Zawartosc popiolu\nZakres (2,0 – 85,0) %\nMetoda wagowa PN-ISO 1171:2002","categories":["petro"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ash content","parameters_en":[{"name":"Range","range":"(2,0 – 85,0) %"}],"search_en":"Solid fuels: hard coal Ash content Gravimetric method Range PN-ISO 1171:2002","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(2,0 – 85,0) %"}],"search_zh":"固体燃料：烟煤 灰分含量 重量法 范围 PN-ISO 1171:2002","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a837a57af14b9c0e7b1fd69","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość popiołu","parameters":[{"name":"Zakres","range":"(2,00 – 85,00) %"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)"],"computed":[],"activity":"Zawartość popiołu\nZakres (2,00 – 85,00) %\nMetoda termograwimetryczna (TGA)","reference":"PN-G-04560:1998","norm_bases":["PN-G-04560:1998"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość popiołu\nZakres (2,00 – 85,00) %\nMetoda termograwimetryczna (TGA) PN-G-04560:1998 Paliwa stale: wegiel kamienny Zawartosc popiolu\nZakres (2,00 – 85,00) %\nMetoda termograwimetryczna (TGA) PN-G-04560:1998","categories":["petro"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ash content","parameters_en":[{"name":"Range","range":"(2,00 – 85,00) %"}],"search_en":"Solid fuels: hard coal Ash content Thermogravimetric method (TGA) Range PN-G-04560:1998","technique_en":"Thermogravimetric method (TGA)","test_object_en":"Solid fuels: hard coal","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(2,00 – 85,00) %"}],"search_zh":"固体燃料：烟煤 灰分含量 热重法（TGA） 范围 PN-G-04560:1998","technique_zh":"热重法（TGA）","test_object_zh":"固体燃料：烟煤"},{"_id":"6a837a57af14b9c0e7b1fd6a","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość siarki całkowitej","parameters":[{"name":"Zakres","range":"(0,10 – 5,20) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość siarki całkowitej\nZakres (0,10 – 5,20) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04584:2001 | ISO 19579:2006","norm_bases":["PN-G-04584:2001","ISO 19579:2006"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość siarki całkowitej\nZakres (0,10 – 5,20) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04584:2001 | ISO 19579:2006 Paliwa stale: wegiel kamienny Zawartosc siarki calkowitej\nZakres (0,10 – 5,20) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04584:2001 | ISO 19579:2006","categories":["petro"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total sulfur content","parameters_en":[{"name":"Range","range":"(0,10 – 5,20) %"}],"search_en":"Solid fuels: hard coal Total sulfur content High-temperature combustion with IR detection Range PN-G-04584:2001 | ISO 19579:2006","technique_en":"High-temperature combustion with IR detection","test_object_en":"Solid fuels: hard coal","methodology_zh":"全硫含量","parameters_zh":[{"name":"范围","range":"(0,10 – 5,20) %"}],"search_zh":"固体燃料：烟煤 全硫含量 高温燃烧红外检测法 范围 PN-G-04584:2001 | ISO 19579:2006","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a837a57af14b9c0e7b1fd6b","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość siarki w popiele z węgla kamiennego","parameters":[{"name":"Zakres","range":"(0,20 – 3,20) %"},{"name":"Zawartość siarki popiołowej (z obliczeń) Zawartość siarki palnej (z obliczeń)"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość siarki w popiele z węgla kamiennego\nZakres:\nZakres (0,20 – 3,20) %\nZawartość siarki popiołowej (z obliczeń) Zawartość siarki palnej (z obliczeń)\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04584:2001","norm_bases":["PN-G-04584:2001"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość siarki w popiele z węgla kamiennego\nZakres:\nZakres (0,20 – 3,20) %\nZawartość siarki popiołowej (z obliczeń) Zawartość siarki palnej (z obliczeń)\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04584:2001 Paliwa stale: wegiel kamienny Zawartosc siarki w popiele z wegla kamiennego\nZakres:\nZakres (0,20 – 3,20) %\nZawartosc siarki popiolowej (z obliczen) Zawartosc siarki palnej (z obliczen)\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04584:2001","categories":["petro"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,20 – 3,20) %"},{"name":"Zawartość siarki popiołowej (z obliczeń) Zawartość siarki palnej (z obliczeń)"}],"search_en":"Solid fuels: hard coal High-temperature combustion with IR detection Range PN-G-04584:2001","technique_en":"High-temperature combustion with IR detection","test_object_en":"Solid fuels: hard coal","parameters_zh":[{"name":"范围","range":"(0,20 – 3,20) %"},{"name":"Zawartość siarki popiołowej (z obliczeń) Zawartość siarki palnej (z obliczeń)"}],"search_zh":"固体燃料：烟煤 高温燃烧红外检测法 范围 PN-G-04584:2001","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a837a57af14b9c0e7b1fd6c","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość siarki pirytowej","parameters":[{"name":"Zakres","range":"(0,01 - 3,00) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość siarki pirytowej\nZakres (0,01 - 3,00) %\nMetoda wagowa","reference":"PN-G-04582:1997","norm_bases":["PN-G-04582:1997"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość siarki pirytowej\nZakres (0,01 - 3,00) %\nMetoda wagowa PN-G-04582:1997 Paliwa stale: wegiel kamienny Zawartosc siarki pirytowej\nZakres (0,01 - 3,00) %\nMetoda wagowa PN-G-04582:1997","categories":["petro"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Pyritic sulfur content","parameters_en":[{"name":"Range","range":"(0,01 - 3,00) %"}],"search_en":"Solid fuels: hard coal Pyritic sulfur content Gravimetric method Range PN-G-04582:1997","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","parameters_zh":[{"name":"范围","range":"(0,01 - 3,00) %"}],"search_zh":"固体燃料：烟煤 重量法 范围 PN-G-04582:1997","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a837a57af14b9c0e7b1fd6d","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Ciepło spalania","parameters":[{"name":"Zakres","range":"(2500 – 34000) kJ/kg"},{"name":"Wartość opałowa (z obliczeń)"}],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna"],"computed":[],"activity":"Ciepło spalania\nZakres:\nZakres (2500 – 34000) kJ/kg\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna","reference":"PN-81/G-04513 | PN-ISO 1928:2020-05","norm_bases":["PN-81/G-04513","PN-ISO 1928:2020-05"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Ciepło spalania\nZakres:\nZakres (2500 – 34000) kJ/kg\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna PN-81/G-04513 | PN-ISO 1928:2020-05 Paliwa stale: wegiel kamienny Cieplo spalania\nZakres:\nZakres (2500 – 34000) kJ/kg\nWartosc opalowa (z obliczen)\nMetoda kalorymetryczna PN-81/G-04513 | PN-ISO 1928:2020-05","categories":["petro"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gross calorific value","parameters_en":[{"name":"Range","range":"(2500 – 34000) kJ/kg"},{"name":"Net calorific value (calculated)"}],"search_en":"Solid fuels: hard coal Gross calorific value Calorimetric method Range Net calorific value (calculated) PN-81/G-04513 | PN-ISO 1928:2020-05","technique_en":"Calorimetric method","test_object_en":"Solid fuels: hard coal","methodology_zh":"高位发热量","parameters_zh":[{"name":"范围","range":"(2500 – 34000) kJ/kg"},{"name":"低位发热量（计算值）"}],"search_zh":"固体燃料：烟煤 高位发热量 量热法 范围 低位发热量（计算值） PN-81/G-04513 | PN-ISO 1928:2020-05","technique_zh":"量热法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a837a57af14b9c0e7b1fd6e","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość tlenu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość tlenu (z obliczeń)","reference":"PN-ISO 1928:2020-05","norm_bases":["PN-ISO 1928:2020-05"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość tlenu (z obliczeń) PN-ISO 1928:2020-05 Paliwa stale: wegiel kamienny Zawartosc tlenu (z obliczen) PN-ISO 1928:2020-05","categories":["petro"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Oxygen content (calculated)","search_en":"Solid fuels: hard coal Oxygen content (calculated) PN-ISO 1928:2020-05","test_object_en":"Solid fuels: hard coal","search_zh":"固体燃料：烟煤 氧含量（由计算得出） PN-ISO 1928:2020-05","test_object_zh":"固体燃料：烟煤","methodology_zh":"氧含量（由计算得出）"},{"_id":"6a837a57af14b9c0e7b1fd6f","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość części lotnych","parameters":[{"name":"Zakres","range":"(10,0 – 40,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość części lotnych\nZakres (10,0 – 40,0) %\nMetoda wagowa","reference":"PN-G-04516:1998","norm_bases":["PN-G-04516:1998"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość części lotnych\nZakres (10,0 – 40,0) %\nMetoda wagowa PN-G-04516:1998 Paliwa stale: wegiel kamienny Zawartosc czesci lotnych\nZakres (10,0 – 40,0) %\nMetoda wagowa PN-G-04516:1998","categories":["petro"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Volatile matter content","parameters_en":[{"name":"Range","range":"(10,0 – 40,0) %"}],"search_en":"Solid fuels: hard coal Volatile matter content Gravimetric method Range PN-G-04516:1998","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","parameters_zh":[{"name":"范围","range":"(10,0 – 40,0) %"}],"search_zh":"固体燃料：烟煤 挥发分含量 重量法 范围 PN-G-04516:1998","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤","methodology_zh":"挥发分含量"},{"_id":"6a837a57af14b9c0e7b1fd70","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość węgla całkowitego","parameters":[{"name":"Zakres","range":"(10,0 – 90,0) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość węgla całkowitego\nZakres (10,0 – 90,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04571:1998 | ISO 29541:2025-02","norm_bases":["PN-G-04571:1998","ISO 29541:2025-02"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość węgla całkowitego\nZakres (10,0 – 90,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04571:1998 | ISO 29541:2025-02 Paliwa stale: wegiel kamienny Zawartosc wegla calkowitego\nZakres (10,0 – 90,0) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04571:1998 | ISO 29541:2025-02","categories":["petro"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total carbon content","parameters_en":[{"name":"Range","range":"(10,0 – 90,0) %"}],"search_en":"Solid fuels: hard coal Total carbon content High-temperature combustion with IR detection Range PN-G-04571:1998 | ISO 29541:2025-02","technique_en":"High-temperature combustion with IR detection","test_object_en":"Solid fuels: hard coal","methodology_zh":"总碳含量","parameters_zh":[{"name":"范围","range":"(10,0 – 90,0) %"}],"search_zh":"固体燃料：烟煤 总碳含量 高温燃烧红外检测法 范围 PN-G-04571:1998 | ISO 29541:2025-02","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a837a57af14b9c0e7b1fd71","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wodoru","parameters":[{"name":"Zakres","range":"(1,50 – 6,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość wodoru\nZakres (1,50 – 6,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04571:1998 | ISO 29541:2025-02","norm_bases":["PN-G-04571:1998","ISO 29541:2025-02"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wodoru\nZakres (1,50 – 6,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04571:1998 | ISO 29541:2025-02 Paliwa stale: wegiel kamienny Zawartosc wodoru\nZakres (1,50 – 6,00) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04571:1998 | ISO 29541:2025-02","categories":["petro"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrogen content","parameters_en":[{"name":"Range","range":"(1,50 – 6,00) %"}],"search_en":"Solid fuels: hard coal Hydrogen content High-temperature combustion with IR detection Range PN-G-04571:1998 | ISO 29541:2025-02","technique_en":"High-temperature combustion with IR detection","test_object_en":"Solid fuels: hard coal","parameters_zh":[{"name":"范围","range":"(1,50 – 6,00) %"}],"search_zh":"固体燃料：烟煤 氢含量 高温燃烧红外检测法 范围 PN-G-04571:1998 | ISO 29541:2025-02","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：烟煤","methodology_zh":"氢含量"},{"_id":"6a837a57af14b9c0e7b1fd72","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość azotu","parameters":[{"name":"Zakres","range":"(0,20 – 2,50) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją TC","techniques":["Metoda wysokotemperaturowego spalania z detekcją TC"],"computed":[],"activity":"Zawartość azotu\nZakres (0,20 – 2,50) %\nMetoda wysokotemperaturowego spalania z detekcją TC","reference":"ISO 29541:2025-02","norm_bases":["ISO 29541:2025-02"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość azotu\nZakres (0,20 – 2,50) %\nMetoda wysokotemperaturowego spalania z detekcją TC ISO 29541:2025-02 Paliwa stale: wegiel kamienny Zawartosc azotu\nZakres (0,20 – 2,50) %\nMetoda wysokotemperaturowego spalania z detekcja TC ISO 29541:2025-02","categories":["petro"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrogen content","parameters_en":[{"name":"Range","range":"(0,20 – 2,50) %"}],"search_en":"Solid fuels: hard coal Nitrogen content High-temperature combustion with TC detection Range ISO 29541:2025-02","technique_en":"High-temperature combustion with TC detection","test_object_en":"Solid fuels: hard coal","methodology_zh":"氮含量","parameters_zh":[{"name":"范围","range":"(0,20 – 2,50) %"}],"search_zh":"固体燃料：烟煤 氮含量 高温燃烧总碳检测法 范围 ISO 29541:2025-02","test_object_zh":"固体燃料：烟煤","technique_zh":"高温燃烧总碳检测法"},{"_id":"6a837a57af14b9c0e7b1fd73","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość azotu","parameters":[{"name":"Zakres","range":"(0,20 – 1,80) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją TC","techniques":["Metoda wysokotemperaturowego spalania z detekcją TC"],"computed":[],"activity":"Zawartość azotu\nZakres (0,20 – 1,80) %\nMetoda wysokotemperaturowego spalania z detekcją TC","reference":"PN-G-04571:1998","norm_bases":["PN-G-04571:1998"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość azotu\nZakres (0,20 – 1,80) %\nMetoda wysokotemperaturowego spalania z detekcją TC PN-G-04571:1998 Paliwa stale: wegiel kamienny Zawartosc azotu\nZakres (0,20 – 1,80) %\nMetoda wysokotemperaturowego spalania z detekcja TC PN-G-04571:1998","categories":["petro"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrogen content","parameters_en":[{"name":"Range","range":"(0,20 – 1,80) %"}],"search_en":"Solid fuels: hard coal Nitrogen content High-temperature combustion with TC detection Range PN-G-04571:1998","technique_en":"High-temperature combustion with TC detection","test_object_en":"Solid fuels: hard coal","methodology_zh":"氮含量","parameters_zh":[{"name":"范围","range":"(0,20 – 1,80) %"}],"search_zh":"固体燃料：烟煤 氮含量 高温燃烧总碳检测法 范围 PN-G-04571:1998","test_object_zh":"固体燃料：烟煤","technique_zh":"高温燃烧总碳检测法"},{"_id":"6a837a57af14b9c0e7b1fd74","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość chloru","parameters":[{"name":"Zakres","range":"(0,010 - 1,200) %"}],"technique":"Metoda miareczkowania potencjometrycznego","techniques":["Metoda miareczkowania potencjometrycznego"],"computed":[],"activity":"Zawartość chloru\nZakres (0,010 - 1,200) %\nMetoda miareczkowania potencjometrycznego","reference":"IB-DPA-21 wersja 07 z dnia 02-01-2026 r.","norm_bases":["IB-DPA-21 wersja 07 z dnia 02-01-2026 r."],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość chloru\nZakres (0,010 - 1,200) %\nMetoda miareczkowania potencjometrycznego IB-DPA-21 wersja 07 z dnia 02-01-2026 r. Paliwa stale: wegiel kamienny Zawartosc chloru\nZakres (0,010 - 1,200) %\nMetoda miareczkowania potencjometrycznego IB-DPA-21 wersja 07 z dnia 02-01-2026 r.","categories":["petro"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chlorine content","parameters_en":[{"name":"Range","range":"(0,010 - 1,200) %"}],"search_en":"Solid fuels: hard coal Chlorine content Potentiometric titration method Range IB-DPA-21 wersja 07 z dnia 02-01-2026 r.","technique_en":"Potentiometric titration method","test_object_en":"Solid fuels: hard coal","parameters_zh":[{"name":"范围","range":"(0,010 - 1,200) %"}],"search_zh":"固体燃料：烟煤 氯含量 电位滴定法 范围 IB-DPA-21 wersja 07 z dnia 02-01-2026 r.","technique_zh":"电位滴定法","test_object_zh":"固体燃料：烟煤","methodology_zh":"氯含量"},{"_id":"6a837a57af14b9c0e7b1fd75","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość fluoru","parameters":[{"name":"Zakres","range":"(0,001-0,030) %"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"Zawartość fluoru\nZakres (0,001-0,030) %\nMetoda potencjometryczna","reference":"PN-82/G-04543 pkt 3.3","norm_bases":["PN-82/G-04543 pkt 3.3"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość fluoru\nZakres (0,001-0,030) %\nMetoda potencjometryczna PN-82/G-04543 pkt 3.3 Paliwa stale: wegiel kamienny Zawartosc fluoru\nZakres (0,001-0,030) %\nMetoda potencjometryczna PN-82/G-04543 pkt 3.3","categories":["petro"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fluorine content","parameters_en":[{"name":"Range","range":"(0,001-0,030) %"}],"search_en":"Solid fuels: hard coal Fluorine content Potentiometric method Range PN-82/G-04543 pkt 3.3","technique_en":"Potentiometric method","test_object_en":"Solid fuels: hard coal","parameters_zh":[{"name":"范围","range":"(0,001-0,030) %"}],"search_zh":"固体燃料：烟煤 氟含量 电位法 范围 PN-82/G-04543 pkt 3.3","technique_zh":"电位法","test_object_zh":"固体燃料：烟煤","methodology_zh":"氟含量"},{"_id":"6a837a57af14b9c0e7b1fd76","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość chloru","parameters":[{"name":"Zakres","range":"(0,020 - 1,200) %"}],"technique":"Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii (EDXRF)","techniques":["Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii (EDXRF)"],"computed":[],"activity":"Zawartość chloru\nZakres (0,020 - 1,200) %\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii (EDXRF)","reference":"IB-DPA-26 wersja 04 z dnia 02-01-2026 r.","norm_bases":["IB-DPA-26 wersja 04 z dnia 02-01-2026 r."],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość chloru\nZakres (0,020 - 1,200) %\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii (EDXRF) IB-DPA-26 wersja 04 z dnia 02-01-2026 r. Paliwa stale: wegiel kamienny Zawartosc chloru\nZakres (0,020 - 1,200) %\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersja energii (EDXRF) IB-DPA-26 wersja 04 z dnia 02-01-2026 r.","categories":["petro"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chlorine content","parameters_en":[{"name":"Range","range":"(0,020 - 1,200) %"}],"search_en":"Solid fuels: hard coal Chlorine content Energy dispersive X-ray fluorescence spectrometry method (EDXRF) Range IB-DPA-26 wersja 04 z dnia 02-01-2026 r.","technique_en":"Energy dispersive X-ray fluorescence spectrometry method (EDXRF)","test_object_en":"Solid fuels: hard coal","parameters_zh":[{"name":"范围","range":"(0,020 - 1,200) %"}],"search_zh":"固体燃料：烟煤 氯含量 范围 IB-DPA-26 wersja 04 z dnia 02-01-2026 r.","test_object_zh":"固体燃料：烟煤","methodology_zh":"氯含量"},{"_id":"6a837a57af14b9c0e7b1fd77","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość bromu","parameters":[{"name":"Zakres","range":"(0,0002 – 0,0200) %"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Zawartość bromu\nZakres (0,0002 – 0,0200) %\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN 15408:2011","norm_bases":["PN-EN 15408:2011"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość bromu\nZakres (0,0002 – 0,0200) %\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN 15408:2011 Paliwa stale: wegiel kamienny Zawartosc bromu\nZakres (0,0002 – 0,0200) %\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN 15408:2011","categories":["petro"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Bromine content","parameters_en":[{"name":"Range","range":"(0,0002 – 0,0200) %"}],"search_en":"Solid fuels: hard coal Bromine content Ion chromatography with conductometric detection (IC-CD) Range PN-EN 15408:2011","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Solid fuels: hard coal","parameters_zh":[{"name":"范围","range":"(0,0002 – 0,0200) %"}],"search_zh":"固体燃料：烟煤 溴含量 离子色谱-电导检测法（IC-CD） 范围 PN-EN 15408:2011","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"固体燃料：烟煤","methodology_zh":"溴含量"},{"_id":"6a837a57af14b9c0e7b1fd78","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość fluoru","parameters":[{"name":"Zakres","range":"(0,0020 – 0,0300) %"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Zawartość fluoru\nZakres (0,0020 – 0,0300) %\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN 15408:2011","norm_bases":["PN-EN 15408:2011"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość fluoru\nZakres (0,0020 – 0,0300) %\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN 15408:2011 Paliwa stale: wegiel kamienny Zawartosc fluoru\nZakres (0,0020 – 0,0300) %\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN 15408:2011","categories":["petro"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fluorine content","parameters_en":[{"name":"Range","range":"(0,0020 – 0,0300) %"}],"search_en":"Solid fuels: hard coal Fluorine content Ion chromatography with conductometric detection (IC-CD) Range PN-EN 15408:2011","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Solid fuels: hard coal","parameters_zh":[{"name":"范围","range":"(0,0020 – 0,0300) %"}],"search_zh":"固体燃料：烟煤 氟含量 离子色谱-电导检测法（IC-CD） 范围 PN-EN 15408:2011","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"固体燃料：烟煤","methodology_zh":"氟含量"},{"_id":"6a837a57af14b9c0e7b1fd79","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Fixed carbon (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Fixed carbon (z obliczeń)","reference":"PN-G-04516:1998","norm_bases":["PN-G-04516:1998"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Fixed carbon (z obliczeń) PN-G-04516:1998 Paliwa stale: wegiel kamienny Fixed carbon (z obliczen) PN-G-04516:1998","categories":["petro"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fixed carbon (calculated)","search_en":"Solid fuels: hard coal Fixed carbon (calculated) PN-G-04516:1998","test_object_en":"Solid fuels: hard coal","search_zh":"固体燃料：烟煤 固定碳（由计算得出） PN-G-04516:1998","test_object_zh":"固体燃料：烟煤","methodology_zh":"固定碳（由计算得出）"},{"_id":"6a837a57af14b9c0e7b1fd7a","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość pierwiastków i tlenków w popiele z węgla kamiennego:","parameters":[{"name":"Si","range":"(0,05 – 44,4) %"},{"name":"SiO2","range":"(0,10 – 95,0) %"},{"name":"Al","range":"(0,009 – 21,2)%"},{"name":"Al2O3","range":"(0,017 – 40,0) %"},{"name":"Fe","range":"(0,07 – 28,0) %"},{"name":"Fe2O3","range":"(0,10 – 40,0) %"},{"name":"Ca","range":"(0,01 – 50,0) %"},{"name":"CaO","range":"(0,02 – 70,0) %"},{"name":"Mg","range":"(0,02 – 18,1) %"},{"name":"MgO","range":"(0,03 – 30,0) %"},{"name":"Na","range":"(0,007 – 7,4) %"},{"name":"Na2O","range":"(0,01 – 10,0) %"},{"name":"K","range":"(0,008 – 8,3) %"},{"name":"K2O","range":"(0,01 – 10,0)%"},{"name":"P","range":"(0,01 – 10,0) %"},{"name":"Ti","range":"(0,01 – 10,0) %"},{"name":"As","range":"(10,0 – 1000) mg/kg"},{"name":"B","range":"(14,0 – 5300) mg/kg"},{"name":"Ba","range":"(10,0 – 14300) mg/kg"},{"name":"Cd","range":"(7,0 – 30,0) mg/kg"},{"name":"Co","range":"(8,0 – 100) mg/kg"},{"name":"Cr","range":"(10,0 – 300) mg/kg"},{"name":"Cu","range":"(10,0 – 5000) mg/kg"},{"name":"Mo","range":"(8,0 – 100) mg/kg"},{"name":"Mn","range":"(6,0 – 3500) mg/kg"},{"name":"Ni","range":"(8,0 – 1500) mg/kg"},{"name":"Pb","range":"(5,0 – 1500) mg/kg"},{"name":"Sn","range":"(2,0 – 1000) mg/kg"},{"name":"Sr","range":"(19,0 – 1000) mg/kg"},{"name":"V","range":"(7,0 – 4000) mg/kg"},{"name":"Zn","range":"(5,0 – 5500) mg/kg"},{"name":"Zawartość pierwiastków i tlenków w węglu kamiennym (z obliczeń)"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość pierwiastków i tlenków w popiele z węgla kamiennego:\nZakres:\nSi (0,05 – 44,4) %\nSiO2 (0,10 – 95,0) %\nAl (0,009 – 21,2)%\nAl2O3 (0,017 – 40,0) %\nFe (0,07 – 28,0) %\nFe2O3 (0,10 – 40,0) %\nCa (0,01 – 50,0) %\nCaO (0,02 – 70,0) %\nMg (0,02 – 18,1) %\nMgO (0,03 – 30,0) %\nNa (0,007 – 7,4) %\nNa2O (0,01 – 10,0) %\nK (0,008 – 8,3) %\nK2O (0,01 – 10,0)%\nP (0,01 – 10,0) %\nTi (0,01 – 10,0) %\nAs (10,0 – 1000) mg/kg\nB (14,0 – 5300) mg/kg\nBa (10,0 – 14300) mg/kg\nCd (7,0 – 30,0) mg/kg\nCo (8,0 – 100) mg/kg\nCr (10,0 – 300) mg/kg\nCu (10,0 – 5000) mg/kg\nMo (8,0 – 100) mg/kg\nMn (6,0 – 3500) mg/kg\nNi (8,0 – 1500) mg/kg\nPb (5,0 – 1500) mg/kg\nSn (2,0 – 1000) mg/kg\nSr (19,0 – 1000) mg/kg\nV (7,0 – 4000) mg/kg\nZn (5,0 – 5500) mg/kg\nZawartość pierwiastków i tlenków w węglu kamiennym (z obliczeń)\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN 13657:2006 | PN-EN 13656:2021-05 | PN-EN ISO 11885:2009","norm_bases":["PN-EN 13657:2006","PN-EN 13656:2021-05","PN-EN ISO 11885:2009"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość pierwiastków i tlenków w popiele z węgla kamiennego:\nZakres:\nSi (0,05 – 44,4) %\nSiO2 (0,10 – 95,0) %\nAl (0,009 – 21,2)%\nAl2O3 (0,017 – 40,0) %\nFe (0,07 – 28,0) %\nFe2O3 (0,10 – 40,0) %\nCa (0,01 – 50,0) %\nCaO (0,02 – 70,0) %\nMg (0,02 – 18,1) %\nMgO (0,03 – 30,0) %\nNa (0,007 – 7,4) %\nNa2O (0,01 – 10,0) %\nK (0,008 – 8,3) %\nK2O (0,01 – 10,0)%\nP (0,01 – 10,0) %\nTi (0,01 – 10,0) %\nAs (10,0 – 1000) mg/kg\nB (14,0 – 5300) mg/kg\nBa (10,0 – 14300) mg/kg\nCd (7,0 – 30,0) mg/kg\nCo (8,0 – 100) mg/kg\nCr (10,0 – 300) mg/kg\nCu (10,0 – 5000) mg/kg\nMo (8,0 – 100) mg/kg\nMn (6,0 – 3500) mg/kg\nNi (8,0 – 1500) mg/kg\nPb (5,0 – 1500) mg/kg\nSn (2,0 – 1000) mg/kg\nSr (19,0 – 1000) mg/kg\nV (7,0 – 4000) mg/kg\nZn (5,0 – 5500) mg/kg\nZawartość pierwiastków i tlenków w węglu kamiennym (z obliczeń)\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN 13657:2006 | PN-EN 13656:2021-05 | PN-EN ISO 11885:2009 Paliwa stale: wegiel kamienny Zawartosc pierwiastkow i tlenkow w popiele z wegla kamiennego:\nZakres:\nSi (0,05 – 44,4) %\nSiO2 (0,10 – 95,0) %\nAl (0,009 – 21,2)%\nAl2O3 (0,017 – 40,0) %\nFe (0,07 – 28,0) %\nFe2O3 (0,10 – 40,0) %\nCa (0,01 – 50,0) %\nCaO (0,02 – 70,0) %\nMg (0,02 – 18,1) %\nMgO (0,03 – 30,0) %\nNa (0,007 – 7,4) %\nNa2O (0,01 – 10,0) %\nK (0,008 – 8,3) %\nK2O (0,01 – 10,0)%\nP (0,01 – 10,0) %\nTi (0,01 – 10,0) %\nAs (10,0 – 1000) mg/kg\nB (14,0 – 5300) mg/kg\nBa (10,0 – 14300) mg/kg\nCd (7,0 – 30,0) mg/kg\nCo (8,0 – 100) mg/kg\nCr (10,0 – 300) mg/kg\nCu (10,0 – 5000) mg/kg\nMo (8,0 – 100) mg/kg\nMn (6,0 – 3500) mg/kg\nNi (8,0 – 1500) mg/kg\nPb (5,0 – 1500) mg/kg\nSn (2,0 – 1000) mg/kg\nSr (19,0 – 1000) mg/kg\nV (7,0 – 4000) mg/kg\nZn (5,0 – 5500) mg/kg\nZawartosc pierwiastkow i tlenkow w weglu kamiennym (z obliczen)\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN 13657:2006 | PN-EN 13656:2021-05 | PN-EN ISO 11885:2009","categories":["petro"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of elements and oxides in hard coal ash:","parameters_en":[{"name":"Si","range":"(0,05 – 44,4) %"},{"name":"SiO2","range":"(0,10 – 95,0) %"},{"name":"Al","range":"(0,009 – 21,2)%"},{"name":"Al2O3","range":"(0,017 – 40,0) %"},{"name":"Fe","range":"(0,07 – 28,0) %"},{"name":"Fe2O3","range":"(0,10 – 40,0) %"},{"name":"Ca","range":"(0,01 – 50,0) %"},{"name":"CaO","range":"(0,02 – 70,0) %"},{"name":"Mg","range":"(0,02 – 18,1) %"},{"name":"MgO","range":"(0,03 – 30,0) %"},{"name":"Na","range":"(0,007 – 7,4) %"},{"name":"Na2O","range":"(0,01 – 10,0) %"},{"name":"K","range":"(0,008 – 8,3) %"},{"name":"K2O","range":"(0,01 – 10,0)%"},{"name":"P","range":"(0,01 – 10,0) %"},{"name":"Ti","range":"(0,01 – 10,0) %"},{"name":"As","range":"(10,0 – 1000) mg/kg"},{"name":"B","range":"(14,0 – 5300) mg/kg"},{"name":"Ba","range":"(10,0 – 14300) mg/kg"},{"name":"Cd","range":"(7,0 – 30,0) mg/kg"},{"name":"Co","range":"(8,0 – 100) mg/kg"},{"name":"Cr","range":"(10,0 – 300) mg/kg"},{"name":"Cu","range":"(10,0 – 5000) mg/kg"},{"name":"Mo","range":"(8,0 – 100) mg/kg"},{"name":"Mn","range":"(6,0 – 3500) mg/kg"},{"name":"Ni","range":"(8,0 – 1500) mg/kg"},{"name":"Pb","range":"(5,0 – 1500) mg/kg"},{"name":"Sn","range":"(2,0 – 1000) mg/kg"},{"name":"Sr","range":"(19,0 – 1000) mg/kg"},{"name":"V","range":"(7,0 – 4000) mg/kg"},{"name":"Zn","range":"(5,0 – 5500) mg/kg"},{"name":"Content of elements and oxides in hard coal (calculated)"}],"search_en":"Solid fuels: hard coal Content of elements and oxides in hard coal ash: Inductively coupled plasma optical emission spectrometry (ICP-OES) Si SiO2 Al Al2O3 Fe Fe2O3 Ca CaO Mg MgO Na Na2O K K2O P Ti As B Ba Cd Co Cr Cu Mo Mn Ni Pb Sn Sr V Zn Content of elements and oxides in hard coal (calculated) PN-EN 13657:2006 | PN-EN 13656:2021-05 | PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Solid fuels: hard coal","parameters_zh":[{"name":"Si","range":"(0,05 – 44,4) %"},{"name":"SiO2","range":"(0,10 – 95,0) %"},{"name":"Al","range":"(0,009 – 21,2)%"},{"name":"Al2O3","range":"(0,017 – 40,0) %"},{"name":"Fe","range":"(0,07 – 28,0) %"},{"name":"Fe2O3","range":"(0,10 – 40,0) %"},{"name":"Ca","range":"(0,01 – 50,0) %"},{"name":"CaO","range":"(0,02 – 70,0) %"},{"name":"Mg","range":"(0,02 – 18,1) %"},{"name":"MgO","range":"(0,03 – 30,0) %"},{"name":"Na","range":"(0,007 – 7,4) %"},{"name":"Na2O","range":"(0,01 – 10,0) %"},{"name":"K","range":"(0,008 – 8,3) %"},{"name":"K2O","range":"(0,01 – 10,0)%"},{"name":"P","range":"(0,01 – 10,0) %"},{"name":"Ti","range":"(0,01 – 10,0) %"},{"name":"As","range":"(10,0 – 1000) mg/kg"},{"name":"B","range":"(14,0 – 5300) mg/kg"},{"name":"Ba","range":"(10,0 – 14300) mg/kg"},{"name":"Cd","range":"(7,0 – 30,0) mg/kg"},{"name":"Co","range":"(8,0 – 100) mg/kg"},{"name":"Cr","range":"(10,0 – 300) mg/kg"},{"name":"Cu","range":"(10,0 – 5000) mg/kg"},{"name":"Mo","range":"(8,0 – 100) mg/kg"},{"name":"Mn","range":"(6,0 – 3500) mg/kg"},{"name":"Ni","range":"(8,0 – 1500) mg/kg"},{"name":"Pb","range":"(5,0 – 1500) mg/kg"},{"name":"Sn","range":"(2,0 – 1000) mg/kg"},{"name":"Sr","range":"(19,0 – 1000) mg/kg"},{"name":"V","range":"(7,0 – 4000) mg/kg"},{"name":"Zn","range":"(5,0 – 5500) mg/kg"},{"name":"Zawartość pierwiastków i tlenków w węglu kamiennym (z obliczeń)"}],"search_zh":"固体燃料：烟煤 电感耦合等离子体原子发射光谱法（ICP-OES） Si SiO2 Al Al2O3 Fe Fe2O3 Ca CaO Mg MgO Na Na2O K K2O P Ti As B Ba Cd Co Cr Cu Mo Mn Ni Pb Sn Sr V Zn PN-EN 13657:2006 | PN-EN 13656:2021-05 | PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"固体燃料：烟煤"},{"_id":"6a837a57af14b9c0e7b1fd7b","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość tlenków w popiele z węgla kamiennego","parameters":[{"name":"SiO2","range":"(34,00 – 70,00) %"},{"name":"Fe2O3","range":"(6,00 – 20,00) %"},{"name":"Al2O3","range":"(8,00 – 32,00) %"},{"name":"CaO","range":"(1,00 – 7,00) %"},{"name":"MgO","range":"(1,00 – 3,50) %"},{"name":"Na2O","range":"(0,30 – 4,00) %"},{"name":"K2O","range":"(1,00 – 3,50) %"},{"name":"P2O5","range":"(0,10 – 0,80) %"},{"name":"TiO2","range":"(0,80 – 1,80) %"}],"technique":"Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF)","techniques":["Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF)"],"computed":[],"activity":"Zawartość tlenków w popiele z węgla kamiennego\nZakres:\nSiO2 (34,00 – 70,00) %\nFe2O3 (6,00 – 20,00) %\nAl2O3 (8,00 – 32,00) %\nCaO (1,00 – 7,00) %\nMgO (1,00 – 3,50) %\nNa2O (0,30 – 4,00) %\nK2O (1,00 – 3,50) %\nP2O5 (0,10 – 0,80) %\nTiO2 (0,80 – 1,80) %\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF)","reference":"ISO 13605:2018-10","norm_bases":["ISO 13605:2018-10"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość tlenków w popiele z węgla kamiennego\nZakres:\nSiO2 (34,00 – 70,00) %\nFe2O3 (6,00 – 20,00) %\nAl2O3 (8,00 – 32,00) %\nCaO (1,00 – 7,00) %\nMgO (1,00 – 3,50) %\nNa2O (0,30 – 4,00) %\nK2O (1,00 – 3,50) %\nP2O5 (0,10 – 0,80) %\nTiO2 (0,80 – 1,80) %\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF) ISO 13605:2018-10 Paliwa stale: wegiel kamienny Zawartosc tlenkow w popiele z wegla kamiennego\nZakres:\nSiO2 (34,00 – 70,00) %\nFe2O3 (6,00 – 20,00) %\nAl2O3 (8,00 – 32,00) %\nCaO (1,00 – 7,00) %\nMgO (1,00 – 3,50) %\nNa2O (0,30 – 4,00) %\nK2O (1,00 – 3,50) %\nP2O5 (0,10 – 0,80) %\nTiO2 (0,80 – 1,80) %\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersja fali (WD-XRF) ISO 13605:2018-10","categories":["petro"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of oxides in hard coal ash","parameters_en":[{"name":"SiO2","range":"(34,00 – 70,00) %"},{"name":"Fe2O3","range":"(6,00 – 20,00) %"},{"name":"Al2O3","range":"(8,00 – 32,00) %"},{"name":"CaO","range":"(1,00 – 7,00) %"},{"name":"MgO","range":"(1,00 – 3,50) %"},{"name":"Na2O","range":"(0,30 – 4,00) %"},{"name":"K2O","range":"(1,00 – 3,50) %"},{"name":"P2O5","range":"(0,10 – 0,80) %"},{"name":"TiO2","range":"(0,80 – 1,80) %"}],"search_en":"Solid fuels: hard coal Content of oxides in hard coal ash Wavelength dispersive X-ray fluorescence spectrometry (WD-XRF) SiO2 Fe2O3 Al2O3 CaO MgO Na2O K2O P2O5 TiO2 ISO 13605:2018-10","technique_en":"Wavelength dispersive X-ray fluorescence spectrometry (WD-XRF)","test_object_en":"Solid fuels: hard coal","search_zh":"固体燃料：烟煤 波长色散 X 射线荧光光谱法（WD-XRF） SiO2 Fe2O3 Al2O3 CaO MgO Na2O K2O P2O5 TiO2 ISO 13605:2018-10","test_object_zh":"固体燃料：烟煤","parameters_zh":[{"name":"SiO2","range":"(34,00 – 70,00) %"},{"name":"Fe2O3","range":"(6,00 – 20,00) %"},{"name":"Al2O3","range":"(8,00 – 32,00) %"},{"name":"CaO","range":"(1,00 – 7,00) %"},{"name":"MgO","range":"(1,00 – 3,50) %"},{"name":"Na2O","range":"(0,30 – 4,00) %"},{"name":"K2O","range":"(1,00 – 3,50) %"},{"name":"P2O5","range":"(0,10 – 0,80) %"},{"name":"TiO2","range":"(0,80 – 1,80) %"}],"technique_zh":"波长色散 X 射线荧光光谱法（WD-XRF）"},{"_id":"6a837a57af14b9c0e7b1fd7c","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość rtęci","parameters":[{"name":"Zakres","range":"(0,0010 – 1,000) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","techniques":["Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji"],"computed":[],"activity":"Zawartość rtęci\nZakres (0,0010 – 1,000) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","reference":"IB-DPA-09 wersja 04 z dnia 02-01-2026 r.","norm_bases":["IB-DPA-09 wersja 04 z dnia 02-01-2026 r."],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość rtęci\nZakres (0,0010 – 1,000) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji IB-DPA-09 wersja 04 z dnia 02-01-2026 r. Paliwa stale: wegiel kamienny Zawartosc rteci\nZakres (0,0010 – 1,000) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z technika amalgamacji IB-DPA-09 wersja 04 z dnia 02-01-2026 r.","categories":["petro"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury content","parameters_en":[{"name":"Range","range":"(0,0010 – 1,000) mg/kg"}],"search_en":"Solid fuels: hard coal Mercury content Atomic absorption spectrometry with amalgamation technique Range IB-DPA-09 wersja 04 z dnia 02-01-2026 r.","technique_en":"Atomic absorption spectrometry with amalgamation technique","test_object_en":"Solid fuels: hard coal","methodology_zh":"汞含量","parameters_zh":[{"name":"范围","range":"(0,0010 – 1,000) mg/kg"}],"search_zh":"固体燃料：烟煤 汞含量 原子吸收光谱法（汞齐化技术） 范围 IB-DPA-09 wersja 04 z dnia 02-01-2026 r.","technique_zh":"原子吸收光谱法（汞齐化技术）","test_object_zh":"固体燃料：烟煤"},{"_id":"6a837a57af14b9c0e7b1fd7d","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zdolność spiekania","parameters":[{"name":"Zakres","range":"(0 – 80)"}],"technique":"Metoda Rogi","techniques":["Metoda Rogi"],"computed":[],"activity":"Zdolność spiekania\nZakres (0 – 80)\nMetoda Rogi","reference":"PN-G-04508:2020-05","norm_bases":["PN-G-04508:2020-05"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zdolność spiekania\nZakres (0 – 80)\nMetoda Rogi PN-G-04508:2020-05 Paliwa stale: wegiel kamienny Zdolnosc spiekania\nZakres (0 – 80)\nMetoda Rogi PN-G-04508:2020-05","categories":["petro"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Caking ability","parameters_en":[{"name":"Range","range":"(0 – 80)"}],"search_en":"Solid fuels: hard coal Caking ability Roga method Range PN-G-04508:2020-05","technique_en":"Roga method","test_object_en":"Solid fuels: hard coal","parameters_zh":[{"name":"范围","range":"(0 – 80)"}],"search_zh":"固体燃料：烟煤 黏结性 罗加法（Roga） 范围 PN-G-04508:2020-05","test_object_zh":"固体燃料：烟煤","methodology_zh":"黏结性","technique_zh":"罗加法（Roga）"},{"_id":"6a837a57af14b9c0e7b1fd7e","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","methodology":"Zawartość metali i tlenków w popiele z biomasy","parameters":[{"name":"Al - (0,030 – 4,7) %"},{"name":"Al2O3 - (0,056 – 8,9) %"},{"name":"Ca - (0,50 – 35,0) %"},{"name":"CaO - (0,69 – 49,0) %"},{"name":"Fe - (0,080 – 15,0) %"},{"name":"Fe2O3 - (0,11 – 21,4) %"},{"name":"Mg - (0,090 – 9,50) %"},{"name":"MgO - (0,14 – 15,7) %"},{"name":"P - (0,01 – 35,0) %"},{"name":"K - (0,060 – 28,0) %"},{"name":"K2O - - (0,072 – 33,7)%"},{"name":"Na - (0,002 - 7,60) %"},{"name":"Na2O - (0,026 – 10,24) %"},{"name":"Zawartość metali i tlenków w biomasie (z obliczeń)"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość metali i tlenków w popiele z biomasy\nZakres:\nAl - (0,030 – 4,7) %\nAl2O3 - (0,056 – 8,9) %\nCa - (0,50 – 35,0) %\nCaO - (0,69 – 49,0) %\nFe - (0,080 – 15,0) %\nFe2O3 - (0,11 – 21,4) %\nMg - (0,090 – 9,50) %\nMgO - (0,14 – 15,7) %\nP - (0,01 – 35,0) %\nK - (0,060 – 28,0) %\nK2O - - (0,072 – 33,7)%\nNa - (0,002 - 7,60) %\nNa2O - (0,026 – 10,24) %\nZawartość metali i tlenków w biomasie (z obliczeń)\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 16967:2015-06 | PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 16967:2015-06","PN-EN ISO 11885:2009"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Zawartość metali i tlenków w popiele z biomasy\nZakres:\nAl - (0,030 – 4,7) %\nAl2O3 - (0,056 – 8,9) %\nCa - (0,50 – 35,0) %\nCaO - (0,69 – 49,0) %\nFe - (0,080 – 15,0) %\nFe2O3 - (0,11 – 21,4) %\nMg - (0,090 – 9,50) %\nMgO - (0,14 – 15,7) %\nP - (0,01 – 35,0) %\nK - (0,060 – 28,0) %\nK2O - - (0,072 – 33,7)%\nNa - (0,002 - 7,60) %\nNa2O - (0,026 – 10,24) %\nZawartość metali i tlenków w biomasie (z obliczeń)\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 16967:2015-06 | PN-EN ISO 11885:2009 Paliwa stale: biomasa stala – biopaliwo stale Zawartosc metali i tlenkow w popiele z biomasy\nZakres:\nAl - (0,030 – 4,7) %\nAl2O3 - (0,056 – 8,9) %\nCa - (0,50 – 35,0) %\nCaO - (0,69 – 49,0) %\nFe - (0,080 – 15,0) %\nFe2O3 - (0,11 – 21,4) %\nMg - (0,090 – 9,50) %\nMgO - (0,14 – 15,7) %\nP - (0,01 – 35,0) %\nK - (0,060 – 28,0) %\nK2O - - (0,072 – 33,7)%\nNa - (0,002 - 7,60) %\nNa2O - (0,026 – 10,24) %\nZawartosc metali i tlenkow w biomasie (z obliczen)\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 16967:2015-06 | PN-EN ISO 11885:2009","categories":["materials","petro"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of metals and oxides in biomass ash","parameters_en":[{"name":"Al - (0,030 – 4,7) %"},{"name":"Al2O3 - (0,056 – 8,9) %"},{"name":"Ca - (0,50 – 35,0) %"},{"name":"CaO - (0,69 – 49,0) %"},{"name":"Fe - (0,080 – 15,0) %"},{"name":"Fe2O3 - (0,11 – 21,4) %"},{"name":"Mg - (0,090 – 9,50) %"},{"name":"MgO - (0,14 – 15,7) %"},{"name":"P - (0,01 – 35,0) %"},{"name":"K - (0,060 – 28,0) %"},{"name":"K2O - - (0,072 – 33,7)%"},{"name":"Na - (0,002 - 7,60) %"},{"name":"Na2O - (0,026 – 10,24) %"},{"name":"Content of metals and oxides in biomass (calculated)"}],"search_en":"Solid fuels: solid biomass – solid biofuel Content of metals and oxides in biomass ash Inductively coupled plasma optical emission spectrometry (ICP-OES) Al - (0,030 – 4,7) % Al2O3 - (0,056 – 8,9) % Ca - (0,50 – 35,0) % CaO - (0,69 – 49,0) % Fe - (0,080 – 15,0) % Fe2O3 - (0,11 – 21,4) % Mg - (0,090 – 9,50) % MgO - (0,14 – 15,7) % P - (0,01 – 35,0) % K - (0,060 – 28,0) % K2O - - (0,072 – 33,7)% Na - (0,002 - 7,60) % Na2O - (0,026 – 10,24) % Content of metals and oxides in biomass (calculated) PN-EN ISO 16967:2015-06 | PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Solid fuels: solid biomass – solid biofuel","search_zh":"固体燃料：固体生物质 – 固体生物燃料 电感耦合等离子体原子发射光谱法（ICP-OES） PN-EN ISO 16967:2015-06 | PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料"},{"_id":"6a837a57af14b9c0e7b1fd7f","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","methodology":"Zawartość metali w biomasie","parameters":[{"name":"Cd - (0,015 - 10,0) mg/kg"},{"name":"Co - (0,40 - 90,0) mg/kg"},{"name":"Cr - (4,0 - 800) mg/kg"},{"name":"Cu - (1,0 - 250) mg/kg"},{"name":"Mn - (6,0 - 5000) mg/kg"},{"name":"Mo - (0,10 - 100) mg/kg"},{"name":"Ni - (0,40 - 400) mg/kg"},{"name":"Pb - (0,40 - 100) mg/kg"},{"name":"V - (0,20 - 120) mg/kg"},{"name":"Zn - (2,0 - 900) mg/kg"},{"name":"Zawartość metali w popiele z biomasy (z obliczeń)"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość metali w biomasie\nZakres:\nCd - (0,015 - 10,0) mg/kg\nCo - (0,40 - 90,0) mg/kg\nCr - (4,0 - 800) mg/kg\nCu - (1,0 - 250) mg/kg\nMn - (6,0 - 5000) mg/kg\nMo - (0,10 - 100) mg/kg\nNi - (0,40 - 400) mg/kg\nPb - (0,40 - 100) mg/kg\nV - (0,20 - 120) mg/kg\nZn - (2,0 - 900) mg/kg\nZawartość metali w popiele z biomasy (z obliczeń)\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 16968:2015-07 | PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 16968:2015-07","PN-EN ISO 11885:2009"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Zawartość metali w biomasie\nZakres:\nCd - (0,015 - 10,0) mg/kg\nCo - (0,40 - 90,0) mg/kg\nCr - (4,0 - 800) mg/kg\nCu - (1,0 - 250) mg/kg\nMn - (6,0 - 5000) mg/kg\nMo - (0,10 - 100) mg/kg\nNi - (0,40 - 400) mg/kg\nPb - (0,40 - 100) mg/kg\nV - (0,20 - 120) mg/kg\nZn - (2,0 - 900) mg/kg\nZawartość metali w popiele z biomasy (z obliczeń)\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 16968:2015-07 | PN-EN ISO 11885:2009 Paliwa stale: biomasa stala – biopaliwo stale Zawartosc metali w biomasie\nZakres:\nCd - (0,015 - 10,0) mg/kg\nCo - (0,40 - 90,0) mg/kg\nCr - (4,0 - 800) mg/kg\nCu - (1,0 - 250) mg/kg\nMn - (6,0 - 5000) mg/kg\nMo - (0,10 - 100) mg/kg\nNi - (0,40 - 400) mg/kg\nPb - (0,40 - 100) mg/kg\nV - (0,20 - 120) mg/kg\nZn - (2,0 - 900) mg/kg\nZawartosc metali w popiele z biomasy (z obliczen)\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 16968:2015-07 | PN-EN ISO 11885:2009","categories":["materials","petro"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Metal content in biomass","parameters_en":[{"name":"Cd - (0,015 - 10,0) mg/kg"},{"name":"Co - (0,40 - 90,0) mg/kg"},{"name":"Cr - (4,0 - 800) mg/kg"},{"name":"Cu - (1,0 - 250) mg/kg"},{"name":"Mn - (6,0 - 5000) mg/kg"},{"name":"Mo - (0,10 - 100) mg/kg"},{"name":"Ni - (0,40 - 400) mg/kg"},{"name":"Pb - (0,40 - 100) mg/kg"},{"name":"V - (0,20 - 120) mg/kg"},{"name":"Zn - (2,0 - 900) mg/kg"},{"name":"Metal content in biomass ash (calculated)"}],"search_en":"Solid fuels: solid biomass – solid biofuel Metal content in biomass Inductively coupled plasma optical emission spectrometry (ICP-OES) Cd - (0,015 - 10,0) mg/kg Co - (0,40 - 90,0) mg/kg Cr - (4,0 - 800) mg/kg Cu - (1,0 - 250) mg/kg Mn - (6,0 - 5000) mg/kg Mo - (0,10 - 100) mg/kg Ni - (0,40 - 400) mg/kg Pb - (0,40 - 100) mg/kg V - (0,20 - 120) mg/kg Zn - (2,0 - 900) mg/kg Metal content in biomass ash (calculated) PN-EN ISO 16968:2015-07 | PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Solid fuels: solid biomass – solid biofuel","search_zh":"固体燃料：固体生物质 – 固体生物燃料 电感耦合等离子体原子发射光谱法（ICP-OES） PN-EN ISO 16968:2015-07 | PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料"},{"_id":"6a837a57af14b9c0e7b1fd80","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","methodology":"Zawartość rtęci","parameters":[{"name":"Zakres","range":"(0,0010 – 0,100) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","techniques":["Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji"],"computed":[],"activity":"Zawartość rtęci\nZakres (0,0010 – 0,100) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","reference":"IB-DPA-09 wersja 04 z dnia 02-01-2026 r.","norm_bases":["IB-DPA-09 wersja 04 z dnia 02-01-2026 r."],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Zawartość rtęci\nZakres (0,0010 – 0,100) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji IB-DPA-09 wersja 04 z dnia 02-01-2026 r. Paliwa stale: biomasa stala – biopaliwo stale Zawartosc rteci\nZakres (0,0010 – 0,100) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z technika amalgamacji IB-DPA-09 wersja 04 z dnia 02-01-2026 r.","categories":["petro"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury content","parameters_en":[{"name":"Range","range":"(0,0010 – 0,100) mg/kg"}],"search_en":"Solid fuels: solid biomass – solid biofuel Mercury content Atomic absorption spectrometry with amalgamation technique Range IB-DPA-09 wersja 04 z dnia 02-01-2026 r.","technique_en":"Atomic absorption spectrometry with amalgamation technique","test_object_en":"Solid fuels: solid biomass – solid biofuel","methodology_zh":"汞含量","parameters_zh":[{"name":"范围","range":"(0,0010 – 0,100) mg/kg"}],"search_zh":"固体燃料：固体生物质 – 固体生物燃料 汞含量 原子吸收光谱法（汞齐化技术） 范围 IB-DPA-09 wersja 04 z dnia 02-01-2026 r.","technique_zh":"原子吸收光谱法（汞齐化技术）","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料"},{"_id":"6a837a57af14b9c0e7b1fd81","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","methodology":"Zawartość metali w biomasie","parameters":[{"name":"Si - (0,01 – 45,0) %"},{"name":"SiO2 - (0,02 – 96,3) %"},{"name":"Zawartość Si w popiele z biomasy (z obliczeń)"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość metali w biomasie\nZakres:\nSi - (0,01 – 45,0) %\nSiO2 - (0,02 – 96,3) %\nZawartość Si w popiele z biomasy (z obliczeń)\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 16967:2015-06 | PN-EN ISO 16968:2015-07 | PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 16967:2015-06","PN-EN ISO 16968:2015-07","PN-EN ISO 11885:2009"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Zawartość metali w biomasie\nZakres:\nSi - (0,01 – 45,0) %\nSiO2 - (0,02 – 96,3) %\nZawartość Si w popiele z biomasy (z obliczeń)\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 16967:2015-06 | PN-EN ISO 16968:2015-07 | PN-EN ISO 11885:2009 Paliwa stale: biomasa stala – biopaliwo stale Zawartosc metali w biomasie\nZakres:\nSi - (0,01 – 45,0) %\nSiO2 - (0,02 – 96,3) %\nZawartosc Si w popiele z biomasy (z obliczen)\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 16967:2015-06 | PN-EN ISO 16968:2015-07 | PN-EN ISO 11885:2009","categories":["materials","petro"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Metal content in biomass","parameters_en":[{"name":"Si - (0,01 – 45,0) %"},{"name":"SiO2 - (0,02 – 96,3) %"},{"name":"Si content in biomass ash (calculated)"}],"search_en":"Solid fuels: solid biomass – solid biofuel Metal content in biomass Inductively coupled plasma optical emission spectrometry (ICP-OES) Si - (0,01 – 45,0) % SiO2 - (0,02 – 96,3) % Si content in biomass ash (calculated) PN-EN ISO 16967:2015-06 | PN-EN ISO 16968:2015-07 | PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Solid fuels: solid biomass – solid biofuel","search_zh":"固体燃料：固体生物质 – 固体生物燃料 电感耦合等离子体原子发射光谱法（ICP-OES） PN-EN ISO 16967:2015-06 | PN-EN ISO 16968:2015-07 | PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料"},{"_id":"6a837a57af14b9c0e7b1fd82","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","methodology":"Zawartość chloru","parameters":[{"name":"Zakres","range":"(0,005 -1,000) %"}],"technique":"Metoda miareczkowania potencjometrycznego","techniques":["Metoda miareczkowania potencjometrycznego"],"computed":[],"activity":"Zawartość chloru\nZakres (0,005 -1,000) %\nMetoda miareczkowania potencjometrycznego","reference":"PN-EN ISO 16994:2016-10","norm_bases":["PN-EN ISO 16994:2016-10"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Zawartość chloru\nZakres (0,005 -1,000) %\nMetoda miareczkowania potencjometrycznego PN-EN ISO 16994:2016-10 Paliwa stale: biomasa stala – biopaliwo stale Zawartosc chloru\nZakres (0,005 -1,000) %\nMetoda miareczkowania potencjometrycznego PN-EN ISO 16994:2016-10","categories":["petro"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chlorine content","parameters_en":[{"name":"Range","range":"(0,005 -1,000) %"}],"search_en":"Solid fuels: solid biomass – solid biofuel Chlorine content Potentiometric titration method Range PN-EN ISO 16994:2016-10","technique_en":"Potentiometric titration method","test_object_en":"Solid fuels: solid biomass – solid biofuel","parameters_zh":[{"name":"范围","range":"(0,005 -1,000) %"}],"search_zh":"固体燃料：固体生物质 – 固体生物燃料 氯含量 电位滴定法 范围 PN-EN ISO 16994:2016-10","technique_zh":"电位滴定法","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料","methodology_zh":"氯含量"},{"_id":"6a837a57af14b9c0e7b1fd83","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","methodology":"Zawartość fluoru","parameters":[{"name":"Zakres","range":"(0,001- 0,030) %"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"Zawartość fluoru\nZakres (0,001- 0,030) %\nMetoda potencjometryczna","reference":"PN-82/G-04543 pkt. 3.3 | PN-EN 14582:2017-02","norm_bases":["PN-82/G-04543 pkt. 3.3","PN-EN 14582:2017-02"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Zawartość fluoru\nZakres (0,001- 0,030) %\nMetoda potencjometryczna PN-82/G-04543 pkt. 3.3 | PN-EN 14582:2017-02 Paliwa stale: biomasa stala – biopaliwo stale Zawartosc fluoru\nZakres (0,001- 0,030) %\nMetoda potencjometryczna PN-82/G-04543 pkt. 3.3 | PN-EN 14582:2017-02","categories":["petro"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fluorine content","parameters_en":[{"name":"Range","range":"(0,001- 0,030) %"}],"search_en":"Solid fuels: solid biomass – solid biofuel Fluorine content Potentiometric method Range PN-82/G-04543 pkt. 3.3 | PN-EN 14582:2017-02","technique_en":"Potentiometric method","test_object_en":"Solid fuels: solid biomass – solid biofuel","parameters_zh":[{"name":"范围","range":"(0,001- 0,030) %"}],"search_zh":"固体燃料：固体生物质 – 固体生物燃料 氟含量 电位法 范围 PN-82/G-04543 pkt. 3.3 | PN-EN 14582:2017-02","technique_zh":"电位法","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料","methodology_zh":"氟含量"},{"_id":"6a837a57af14b9c0e7b1fd84","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa ciekłe: olej opałowy lekki","methodology":"Ciepło spalania","parameters":[{"name":"Zakres","range":"(39000 – 46800) kJ/kg"},{"name":"Wartość opałowa (z obliczeń)"}],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna"],"computed":[],"activity":"Ciepło spalania\nZakres:\nZakres (39000 – 46800) kJ/kg\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna","reference":"PN-C-04062:2018-05","norm_bases":["PN-C-04062:2018-05"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej opałowy lekki Ciepło spalania\nZakres:\nZakres (39000 – 46800) kJ/kg\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna PN-C-04062:2018-05 Paliwa ciekle: olej opalowy lekki Cieplo spalania\nZakres:\nZakres (39000 – 46800) kJ/kg\nWartosc opalowa (z obliczen)\nMetoda kalorymetryczna PN-C-04062:2018-05","categories":["petro"],"row_index":55,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gross calorific value","parameters_en":[{"name":"Range","range":"(39000 – 46800) kJ/kg"},{"name":"Net calorific value (calculated)"}],"search_en":"Liquid fuels: light fuel oil Gross calorific value Calorimetric method Range Net calorific value (calculated) PN-C-04062:2018-05","technique_en":"Calorimetric method","test_object_en":"Liquid fuels: light fuel oil","methodology_zh":"高位发热量","parameters_zh":[{"name":"范围","range":"(39000 – 46800) kJ/kg"},{"name":"低位发热量（计算值）"}],"search_zh":"液体燃料：轻质燃料油 高位发热量 量热法 范围 低位发热量（计算值） PN-C-04062:2018-05","technique_zh":"量热法","test_object_zh":"液体燃料：轻质燃料油"},{"_id":"6a837a57af14b9c0e7b1fd85","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa ciekłe: olej opałowy lekki","methodology":"Zawartość wody","parameters":[{"name":"Zakres","range":"(0,003 – 0,03) %m/m"}],"technique":"Metoda miareczkowania kulometrycznego","techniques":["Metoda miareczkowania kulometrycznego"],"computed":[],"activity":"Zawartość wody\nZakres (0,003 – 0,03) %m/m\nMetoda miareczkowania kulometrycznego","reference":"PN-EN ISO 12937:2005 z wyłączeniem pkt. 6.2.4. | PN-EN ISO 12937:2005/Ap1:2021-11","norm_bases":["PN-EN ISO 12937:2005 z wyłączeniem pkt. 6.2.4.","PN-EN ISO 12937:2005/Ap1:2021-11"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej opałowy lekki Zawartość wody\nZakres (0,003 – 0,03) %m/m\nMetoda miareczkowania kulometrycznego PN-EN ISO 12937:2005 z wyłączeniem pkt. 6.2.4. | PN-EN ISO 12937:2005/Ap1:2021-11 Paliwa ciekle: olej opalowy lekki Zawartosc wody\nZakres (0,003 – 0,03) %m/m\nMetoda miareczkowania kulometrycznego PN-EN ISO 12937:2005 z wylaczeniem pkt. 6.2.4. | PN-EN ISO 12937:2005/Ap1:2021-11","categories":["petro","water"],"row_index":56,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water content","parameters_en":[{"name":"Range","range":"(0,003 – 0,03) %m/m"}],"search_en":"Liquid fuels: light fuel oil Water content Coulometric titration method Range PN-EN ISO 12937:2005 z wyłączeniem pkt. 6.2.4. | PN-EN ISO 12937:2005/Ap1:2021-11","technique_en":"Coulometric titration method","test_object_en":"Liquid fuels: light fuel oil","methodology_zh":"水分含量","parameters_zh":[{"name":"范围","range":"(0,003 – 0,03) %m/m"}],"search_zh":"液体燃料：轻质燃料油 水分含量 库仑滴定法 范围 PN-EN ISO 12937:2005 z wyłączeniem pkt. 6.2.4. | PN-EN ISO 12937:2005/Ap1:2021-11","technique_zh":"库仑滴定法","test_object_zh":"液体燃料：轻质燃料油"},{"_id":"6a837a57af14b9c0e7b1fd86","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa ciekłe: olej opałowy lekki","methodology":"Zawartość siarki całkowitej","parameters":[{"name":"Zakres","range":"(0,06 – 0,50) %m/m"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość siarki całkowitej\nZakres (0,06 – 0,50) %m/m\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"ASTM D 1552-23 z wyłączeniem Procedury B","norm_bases":["ASTM D 1552-23 z wyłączeniem Procedury B"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej opałowy lekki Zawartość siarki całkowitej\nZakres (0,06 – 0,50) %m/m\nMetoda wysokotemperaturowego spalania z detekcją IR ASTM D 1552-23 z wyłączeniem Procedury B Paliwa ciekle: olej opalowy lekki Zawartosc siarki calkowitej\nZakres (0,06 – 0,50) %m/m\nMetoda wysokotemperaturowego spalania z detekcja IR ASTM D 1552-23 z wylaczeniem Procedury B","categories":["petro"],"row_index":57,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total sulfur content","parameters_en":[{"name":"Range","range":"(0,06 – 0,50) %m/m"}],"search_en":"Liquid fuels: light fuel oil Total sulfur content High-temperature combustion with IR detection Range ASTM D 1552-23 z wyłączeniem Procedury B","technique_en":"High-temperature combustion with IR detection","test_object_en":"Liquid fuels: light fuel oil","methodology_zh":"全硫含量","parameters_zh":[{"name":"范围","range":"(0,06 – 0,50) %m/m"}],"search_zh":"液体燃料：轻质燃料油 全硫含量 高温燃烧红外检测法 范围 ASTM D 1552-23 z wyłączeniem Procedury B","technique_zh":"高温燃烧红外检测法","test_object_zh":"液体燃料：轻质燃料油"},{"_id":"6a837a57af14b9c0e7b1fd87","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa ciekłe: olej opałowy lekki","methodology":"Zawartość węgla całkowitego","parameters":[{"name":"Zakres","range":"(80,0 - 92,0) %m/m"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość węgla całkowitego\nZakres (80,0 - 92,0) %m/m\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"ASTM D 5291-21 Metoda A","norm_bases":["ASTM D 5291-21 Metoda A"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej opałowy lekki Zawartość węgla całkowitego\nZakres (80,0 - 92,0) %m/m\nMetoda wysokotemperaturowego spalania z detekcją IR ASTM D 5291-21 Metoda A Paliwa ciekle: olej opalowy lekki Zawartosc wegla calkowitego\nZakres (80,0 - 92,0) %m/m\nMetoda wysokotemperaturowego spalania z detekcja IR ASTM D 5291-21 Metoda A","categories":["petro"],"row_index":58,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total carbon content","parameters_en":[{"name":"Range","range":"(80,0 - 92,0) %m/m"}],"search_en":"Liquid fuels: light fuel oil Total carbon content High-temperature combustion with IR detection Range ASTM D 5291-21 Metoda A","technique_en":"High-temperature combustion with IR detection","test_object_en":"Liquid fuels: light fuel oil","methodology_zh":"总碳含量","parameters_zh":[{"name":"范围","range":"(80,0 - 92,0) %m/m"}],"search_zh":"液体燃料：轻质燃料油 总碳含量 高温燃烧红外检测法 范围 ASTM D 5291-21 Metoda A","technique_zh":"高温燃烧红外检测法","test_object_zh":"液体燃料：轻质燃料油"},{"_id":"6a837a57af14b9c0e7b1fd88","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa ciekłe: olej opałowy lekki","methodology":"Zawartość wodoru","parameters":[{"name":"Zakres","range":"(10,00 - 16,00) %m/m"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość wodoru\nZakres (10,00 - 16,00) %m/m\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"ASTM D 5291-21 Metoda A","norm_bases":["ASTM D 5291-21 Metoda A"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej opałowy lekki Zawartość wodoru\nZakres (10,00 - 16,00) %m/m\nMetoda wysokotemperaturowego spalania z detekcją IR ASTM D 5291-21 Metoda A Paliwa ciekle: olej opalowy lekki Zawartosc wodoru\nZakres (10,00 - 16,00) %m/m\nMetoda wysokotemperaturowego spalania z detekcja IR ASTM D 5291-21 Metoda A","categories":["petro"],"row_index":59,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrogen content","parameters_en":[{"name":"Range","range":"(10,00 - 16,00) %m/m"}],"search_en":"Liquid fuels: light fuel oil Hydrogen content High-temperature combustion with IR detection Range ASTM D 5291-21 Metoda A","technique_en":"High-temperature combustion with IR detection","test_object_en":"Liquid fuels: light fuel oil","parameters_zh":[{"name":"范围","range":"(10,00 - 16,00) %m/m"}],"search_zh":"液体燃料：轻质燃料油 氢含量 高温燃烧红外检测法 范围 ASTM D 5291-21 Metoda A","technique_zh":"高温燃烧红外检测法","methodology_zh":"氢含量","test_object_zh":"液体燃料：轻质燃料油"},{"_id":"6a837a57af14b9c0e7b1fd89","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 24, 10 01 80, 10 01 82, Materiał budowlany: popiół lotny do betonu, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Popiół z torfu i drewna","methodology":"Zawartość wolnego tlenku wapnia CaO","parameters":[{"name":"Zakres","range":"(0,01 – 20,0) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość wolnego tlenku wapnia CaO\nZakres (0,01 – 20,0) %\nMetoda miareczkowa","reference":"PN-EN 451-1:2017-06","norm_bases":["PN-EN 451-1:2017-06"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 24, 10 01 80, 10 01 82, Materiał budowlany: popiół lotny do betonu, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Popiół z torfu i drewna Zawartość wolnego tlenku wapnia CaO\nZakres (0,01 – 20,0) %\nMetoda miareczkowa PN-EN 451-1:2017-06 Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 24, 10 01 80, 10 01 82, Material budowlany: popiol lotny do betonu, Popiol, zuzel, Mieszanka popiolowo zuzlowa, Popiol z produktami odsiarczania - lotny, Popiol z produktami odsiarczania - fluidalny, Piaski ze zloz fluidalnych, Popiol z torfu i drewna Zawartosc wolnego tlenku wapnia CaO\nZakres (0,01 – 20,0) %\nMetoda miareczkowa PN-EN 451-1:2017-06","categories":["construction","environment","materials"],"row_index":60,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free calcium oxide CaO content","parameters_en":[{"name":"Range","range":"(0,01 – 20,0) %"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Free calcium oxide CaO content Titrimetric method waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Range PN-EN 451-1:2017-06","technique_en":"Titrimetric method","parameters_zh":[{"name":"范围","range":"(0,01 – 20,0) %"}],"search_zh":"游离氧化钙 CaO 含量 滴定法 依据气候部长关于废物目录的条例的废物代码。 范围 PN-EN 451-1:2017-06","technique_zh":"滴定法","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。","methodology_zh":"游离氧化钙 CaO 含量"},{"_id":"6a837a57af14b9c0e7b1fd8a","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 24, 10 01 80, 10 01 82, Materiał budowlany: popiół lotny do betonu, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Popiół z torfu i drewna","methodology":"Straty prażenia","parameters":[{"name":"Zakres","range":"(0,20 – 35,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Straty prażenia\nZakres (0,20 – 35,0) %\nMetoda wagowa","reference":"PN-EN 196-2:2013 -11 | PN-EN 450-1:2012","norm_bases":["PN-EN 196-2:2013 -11","PN-EN 450-1:2012"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 24, 10 01 80, 10 01 82, Materiał budowlany: popiół lotny do betonu, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Popiół z torfu i drewna Straty prażenia\nZakres (0,20 – 35,0) %\nMetoda wagowa PN-EN 196-2:2013 -11 | PN-EN 450-1:2012 Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 24, 10 01 80, 10 01 82, Material budowlany: popiol lotny do betonu, Popiol, zuzel, Mieszanka popiolowo zuzlowa, Popiol z produktami odsiarczania - lotny, Popiol z produktami odsiarczania - fluidalny, Piaski ze zloz fluidalnych, Popiol z torfu i drewna Straty prazenia\nZakres (0,20 – 35,0) %\nMetoda wagowa PN-EN 196-2:2013 -11 | PN-EN 450-1:2012","categories":["construction","environment","materials"],"row_index":61,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Loss on ignition","parameters_en":[{"name":"Range","range":"(0,20 – 35,0) %"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Loss on ignition Gravimetric method waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Range PN-EN 196-2:2013 -11 | PN-EN 450-1:2012","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(0,20 – 35,0) %"}],"search_zh":"烧失量 重量法 依据气候部长关于废物目录的条例的废物代码。 范围 PN-EN 196-2:2013 -11 | PN-EN 450-1:2012","technique_zh":"重量法","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。","methodology_zh":"烧失量"},{"_id":"6a837a57af14b9c0e7b1fd8b","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 24, 10 01 80, 10 01 82, Materiał budowlany: popiół lotny do betonu, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Popiół z torfu i drewna","methodology":"Miałkość","parameters":[{"name":"Zakres","range":"(10,0 – 50,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Miałkość\nZakres (10,0 – 50,0) %\nMetoda wagowa","reference":"PN-EN 451-2:2017-06","norm_bases":["PN-EN 451-2:2017-06"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 24, 10 01 80, 10 01 82, Materiał budowlany: popiół lotny do betonu, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Popiół z torfu i drewna Miałkość\nZakres (10,0 – 50,0) %\nMetoda wagowa PN-EN 451-2:2017-06 Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 24, 10 01 80, 10 01 82, Material budowlany: popiol lotny do betonu, Popiol, zuzel, Mieszanka popiolowo zuzlowa, Popiol z produktami odsiarczania - lotny, Popiol z produktami odsiarczania - fluidalny, Piaski ze zloz fluidalnych, Popiol z torfu i drewna Mialkosc\nZakres (10,0 – 50,0) %\nMetoda wagowa PN-EN 451-2:2017-06","categories":["construction","environment","materials"],"row_index":62,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fineness","parameters_en":[{"name":"Range","range":"(10,0 – 50,0) %"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Fineness Gravimetric method waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Range PN-EN 451-2:2017-06","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(10,0 – 50,0) %"}],"search_zh":"细度 重量法 依据气候部长关于废物目录的条例的废物代码。 范围 PN-EN 451-2:2017-06","technique_zh":"重量法","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。","methodology_zh":"细度"},{"_id":"6a837a57af14b9c0e7b1fd8c","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 24, 10 01 80, 10 01 82, Materiał budowlany: popiół lotny do betonu, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Popiół z torfu i drewna","methodology":"Zawartość siarki całkowitej","parameters":[{"name":"Zakres","range":"(0,005 – 8,00) %"},{"name":"Zawartość SO3 (z obliczeń)"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość siarki całkowitej\nZakres:\nZakres (0,005 – 8,00) %\nZawartość SO3 (z obliczeń)\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04584:2001","norm_bases":["PN-G-04584:2001"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 24, 10 01 80, 10 01 82, Materiał budowlany: popiół lotny do betonu, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Popiół z torfu i drewna Zawartość siarki całkowitej\nZakres:\nZakres (0,005 – 8,00) %\nZawartość SO3 (z obliczeń)\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04584:2001 Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 24, 10 01 80, 10 01 82, Material budowlany: popiol lotny do betonu, Popiol, zuzel, Mieszanka popiolowo zuzlowa, Popiol z produktami odsiarczania - lotny, Popiol z produktami odsiarczania - fluidalny, Piaski ze zloz fluidalnych, Popiol z torfu i drewna Zawartosc siarki calkowitej\nZakres:\nZakres (0,005 – 8,00) %\nZawartosc SO3 (z obliczen)\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04584:2001","categories":["construction","environment","materials"],"row_index":63,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total sulfur content","parameters_en":[{"name":"Range","range":"(0,005 – 8,00) %"},{"name":"SO3 content (calculated)"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Total sulfur content High-temperature combustion with IR detection waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Range SO3 content (calculated) PN-G-04584:2001","technique_en":"High-temperature combustion with IR detection","methodology_zh":"全硫含量","parameters_zh":[{"name":"范围","range":"(0,005 – 8,00) %"},{"name":"Zawartość SO3 (z obliczeń)"}],"search_zh":"全硫含量 高温燃烧红外检测法 依据气候部长关于废物目录的条例的废物代码。 范围 PN-G-04584:2001","technique_zh":"高温燃烧红外检测法","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。"},{"_id":"6a837a57af14b9c0e7b1fd8d","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 24, 10 01 80, 10 01 82, Materiał budowlany: popiół lotny do betonu, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Popiół z torfu i drewna","methodology":"Zawartość węgla całkowitego","parameters":[{"name":"Zakres","range":"(0,10 – 50,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość węgla całkowitego\nZakres (0,10 – 50,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"IB-DPA-23 wersja 08 z dnia 02-01-2026 r.","norm_bases":["IB-DPA-23 wersja 08 z dnia 02-01-2026 r."],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 24, 10 01 80, 10 01 82, Materiał budowlany: popiół lotny do betonu, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Popiół z torfu i drewna Zawartość węgla całkowitego\nZakres (0,10 – 50,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR IB-DPA-23 wersja 08 z dnia 02-01-2026 r. Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 24, 10 01 80, 10 01 82, Material budowlany: popiol lotny do betonu, Popiol, zuzel, Mieszanka popiolowo zuzlowa, Popiol z produktami odsiarczania - lotny, Popiol z produktami odsiarczania - fluidalny, Piaski ze zloz fluidalnych, Popiol z torfu i drewna Zawartosc wegla calkowitego\nZakres (0,10 – 50,00) %\nMetoda wysokotemperaturowego spalania z detekcja IR IB-DPA-23 wersja 08 z dnia 02-01-2026 r.","categories":["construction","environment","materials"],"row_index":64,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total carbon content","parameters_en":[{"name":"Range","range":"(0,10 – 50,00) %"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Total carbon content High-temperature combustion with IR detection waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Range IB-DPA-23 wersja 08 z dnia 02-01-2026 r.","technique_en":"High-temperature combustion with IR detection","methodology_zh":"总碳含量","parameters_zh":[{"name":"范围","range":"(0,10 – 50,00) %"}],"search_zh":"总碳含量 高温燃烧红外检测法 依据气候部长关于废物目录的条例的废物代码。 范围 IB-DPA-23 wersja 08 z dnia 02-01-2026 r.","technique_zh":"高温燃烧红外检测法","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。"},{"_id":"6a837a57af14b9c0e7b1fd8e","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 24, 10 01 80, 10 01 82, Materiał budowlany: popiół lotny do betonu, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Popiół z torfu i drewna","methodology":"Zawartość reaktywnego CaO (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość reaktywnego CaO (z obliczeń)","reference":"PN-EN 197-1:2012","norm_bases":["PN-EN 197-1:2012"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 24, 10 01 80, 10 01 82, Materiał budowlany: popiół lotny do betonu, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Popiół z torfu i drewna Zawartość reaktywnego CaO (z obliczeń) PN-EN 197-1:2012 Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 24, 10 01 80, 10 01 82, Material budowlany: popiol lotny do betonu, Popiol, zuzel, Mieszanka popiolowo zuzlowa, Popiol z produktami odsiarczania - lotny, Popiol z produktami odsiarczania - fluidalny, Piaski ze zloz fluidalnych, Popiol z torfu i drewna Zawartosc reaktywnego CaO (z obliczen) PN-EN 197-1:2012","categories":["construction","environment","materials"],"row_index":65,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Reactive CaO content (calculated)","regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Reactive CaO content (calculated) waste codes according to the Regulation of the Minister of Climate on the waste catalogue. PN-EN 197-1:2012","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。","search_zh":"依据气候部长关于废物目录的条例的废物代码。 PN-EN 197-1:2012"},{"_id":"6a837a57af14b9c0e7b1fd8f","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 24, 10 01 80, 10 01 82, Materiał budowlany: popiół lotny do betonu, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Popiół z torfu i drewna","methodology":"Zawartość CaO","parameters":[{"name":"Zakres","range":"(0,1 – 21,0) %"},{"name":"Zawartość Ca"},{"name":"Zakres","range":"(0,1 – 15,0) %"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość CaO\nZakres:\nZakres (0,1 – 21,0) %\nZawartość Ca\nZakres (0,1 – 15,0) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN 196-2:2013-11 pkt 4.5.2 z wyłączeniem pkt. 4.5.12 | PN-EN 450-1:2012 pkt 5.2.1 | IB-DPA-25 wersja 08 z dnia 02-01-2026 r.","norm_bases":["PN-EN 196-2:2013-11 pkt 4.5.2 z wyłączeniem pkt. 4.5.12","PN-EN 450-1:2012 pkt 5.2.1","IB-DPA-25 wersja 08 z dnia 02-01-2026 r."],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 24, 10 01 80, 10 01 82, Materiał budowlany: popiół lotny do betonu, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Popiół z torfu i drewna Zawartość CaO\nZakres:\nZakres (0,1 – 21,0) %\nZawartość Ca\nZakres (0,1 – 15,0) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN 196-2:2013-11 pkt 4.5.2 z wyłączeniem pkt. 4.5.12 | PN-EN 450-1:2012 pkt 5.2.1 | IB-DPA-25 wersja 08 z dnia 02-01-2026 r. Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 24, 10 01 80, 10 01 82, Material budowlany: popiol lotny do betonu, Popiol, zuzel, Mieszanka popiolowo zuzlowa, Popiol z produktami odsiarczania - lotny, Popiol z produktami odsiarczania - fluidalny, Piaski ze zloz fluidalnych, Popiol z torfu i drewna Zawartosc CaO\nZakres:\nZakres (0,1 – 21,0) %\nZawartosc Ca\nZakres (0,1 – 15,0) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN 196-2:2013-11 pkt 4.5.2 z wylaczeniem pkt. 4.5.12 | PN-EN 450-1:2012 pkt 5.2.1 | IB-DPA-25 wersja 08 z dnia 02-01-2026 r.","categories":["construction","environment","materials"],"row_index":66,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"CaO content","parameters_en":[{"name":"Range","range":"(0,1 – 21,0) %"},{"name":"Ca content"},{"name":"Range","range":"(0,1 – 15,0) %"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"CaO content Inductively coupled plasma optical emission spectrometry (ICP-OES) waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Range Ca content Range PN-EN 196-2:2013-11 pkt 4.5.2 z wyłączeniem pkt. 4.5.12 | PN-EN 450-1:2012 pkt 5.2.1 | IB-DPA-25 wersja 08 z dnia 02-01-2026 r.","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","parameters_zh":[{"name":"范围","range":"(0,1 – 21,0) %"},{"name":"Zawartość Ca"},{"name":"范围","range":"(0,1 – 15,0) %"}],"search_zh":"CaO 含量 电感耦合等离子体原子发射光谱法（ICP-OES） 依据气候部长关于废物目录的条例的废物代码。 范围 范围 PN-EN 196-2:2013-11 pkt 4.5.2 z wyłączeniem pkt. 4.5.12 | PN-EN 450-1:2012 pkt 5.2.1 | IB-DPA-25 wersja 08 z dnia 02-01-2026 r.","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。","methodology_zh":"CaO 含量"},{"_id":"6a837a57af14b9c0e7b1fd90","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 24, 10 01 80, 10 01 82, Materiał budowlany: popiół lotny do betonu, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Popiół z torfu i drewna","methodology":"Zawartość reaktywnego SiO2 (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość reaktywnego SiO2 (z obliczeń)","reference":"PN-EN 197-1:2012","norm_bases":["PN-EN 197-1:2012"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 24, 10 01 80, 10 01 82, Materiał budowlany: popiół lotny do betonu, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Popiół z torfu i drewna Zawartość reaktywnego SiO2 (z obliczeń) PN-EN 197-1:2012 Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 24, 10 01 80, 10 01 82, Material budowlany: popiol lotny do betonu, Popiol, zuzel, Mieszanka popiolowo zuzlowa, Popiol z produktami odsiarczania - lotny, Popiol z produktami odsiarczania - fluidalny, Piaski ze zloz fluidalnych, Popiol z torfu i drewna Zawartosc reaktywnego SiO2 (z obliczen) PN-EN 197-1:2012","categories":["construction","environment","materials"],"row_index":67,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Reactive SiO2 content (calculated)","regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Reactive SiO2 content (calculated) waste codes according to the Regulation of the Minister of Climate on the waste catalogue. PN-EN 197-1:2012","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。","search_zh":"依据气候部长关于废物目录的条例的废物代码。 PN-EN 197-1:2012"},{"_id":"6a837a57af14b9c0e7b1fd91","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 24, 10 01 80, 10 01 82, Materiał budowlany: popiół lotny do betonu, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Popiół z torfu i drewna","methodology":"Zawartość części nierozpuszczalnych","parameters":[{"name":"Zakres","range":"(1,0 – 50,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość części nierozpuszczalnych\nZakres (1,0 – 50,0) %\nMetoda wagowa","reference":"PN-EN 196-2:2013-11 pkt 4.4.4","norm_bases":["PN-EN 196-2:2013-11 pkt 4.4.4"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 24, 10 01 80, 10 01 82, Materiał budowlany: popiół lotny do betonu, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Popiół z torfu i drewna Zawartość części nierozpuszczalnych\nZakres (1,0 – 50,0) %\nMetoda wagowa PN-EN 196-2:2013-11 pkt 4.4.4 Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 24, 10 01 80, 10 01 82, Material budowlany: popiol lotny do betonu, Popiol, zuzel, Mieszanka popiolowo zuzlowa, Popiol z produktami odsiarczania - lotny, Popiol z produktami odsiarczania - fluidalny, Piaski ze zloz fluidalnych, Popiol z torfu i drewna Zawartosc czesci nierozpuszczalnych\nZakres (1,0 – 50,0) %\nMetoda wagowa PN-EN 196-2:2013-11 pkt 4.4.4","categories":["construction","environment","materials"],"row_index":68,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of insoluble matter","parameters_en":[{"name":"Range","range":"(1,0 – 50,0) %"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Content of insoluble matter Gravimetric method waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Range PN-EN 196-2:2013-11 pkt 4.4.4","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(1,0 – 50,0) %"}],"search_zh":"不溶物含量 重量法 依据气候部长关于废物目录的条例的废物代码。 范围 PN-EN 196-2:2013-11 pkt 4.4.4","technique_zh":"重量法","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。","methodology_zh":"不溶物含量"},{"_id":"6a837a57af14b9c0e7b1fd92","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 24, 10 01 80, 10 01 82, Materiał budowlany: popiół lotny do betonu, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Popiół z torfu i drewna","methodology":"Alkalia (Na + K)","parameters":[{"name":"Zakres","range":"(0,05 – 10,0) %"},{"name":"Zawartość równoważnika Na2O (z obliczeń) Zawartość Na"},{"name":"Zakres","range":"(0,05 – 5,0) %"},{"name":"Zawartość Na2O"},{"name":"Zakres","range":"(0,07 – 6,7) %"},{"name":"Zawartość K"},{"name":"Zakres","range":"(0,05 – 5,0) %"},{"name":"Zawartość K2O"},{"name":"Zakres","range":"(0,06 – 6,0) %"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Alkalia (Na + K)\nZakres:\nZakres (0,05 – 10,0) %\nZawartość równoważnika Na2O (z obliczeń) Zawartość Na\nZakres (0,05 – 5,0) %\nZawartość Na2O\nZakres (0,07 – 6,7) %\nZawartość K\nZakres (0,05 – 5,0) %\nZawartość K2O\nZakres (0,06 – 6,0) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN 196-2:2013-11 pkt. 4.5.19. z wyłączeniem pkt. 4.5.19.5 | IB-DPA-27 wersja 09 z dnia 02-01-2026 r.","norm_bases":["PN-EN 196-2:2013-11 pkt. 4.5.19. z wyłączeniem pkt. 4.5.19.5","IB-DPA-27 wersja 09 z dnia 02-01-2026 r."],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 24, 10 01 80, 10 01 82, Materiał budowlany: popiół lotny do betonu, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Popiół z torfu i drewna Alkalia (Na + K)\nZakres:\nZakres (0,05 – 10,0) %\nZawartość równoważnika Na2O (z obliczeń) Zawartość Na\nZakres (0,05 – 5,0) %\nZawartość Na2O\nZakres (0,07 – 6,7) %\nZawartość K\nZakres (0,05 – 5,0) %\nZawartość K2O\nZakres (0,06 – 6,0) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN 196-2:2013-11 pkt. 4.5.19. z wyłączeniem pkt. 4.5.19.5 | IB-DPA-27 wersja 09 z dnia 02-01-2026 r. Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 24, 10 01 80, 10 01 82, Material budowlany: popiol lotny do betonu, Popiol, zuzel, Mieszanka popiolowo zuzlowa, Popiol z produktami odsiarczania - lotny, Popiol z produktami odsiarczania - fluidalny, Piaski ze zloz fluidalnych, Popiol z torfu i drewna Alkalia (Na + K)\nZakres:\nZakres (0,05 – 10,0) %\nZawartosc rownowaznika Na2O (z obliczen) Zawartosc Na\nZakres (0,05 – 5,0) %\nZawartosc Na2O\nZakres (0,07 – 6,7) %\nZawartosc K\nZakres (0,05 – 5,0) %\nZawartosc K2O\nZakres (0,06 – 6,0) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN 196-2:2013-11 pkt. 4.5.19. z wylaczeniem pkt. 4.5.19.5 | IB-DPA-27 wersja 09 z dnia 02-01-2026 r.","categories":["construction","environment","materials"],"row_index":69,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Alkalis (Na + K)","parameters_en":[{"name":"Range","range":"(0,05 – 10,0) %"},{"name":"Na2O equivalent content (calculated) Na content"},{"name":"Range","range":"(0,05 – 5,0) %"},{"name":"Na2O content"},{"name":"Range","range":"(0,07 – 6,7) %"},{"name":"K content"},{"name":"Range","range":"(0,05 – 5,0) %"},{"name":"K2O content"},{"name":"Range","range":"(0,06 – 6,0) %"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Alkalis (Na + K) Inductively coupled plasma optical emission spectrometry (ICP-OES) waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Range Na2O equivalent content (calculated) Na content Range Na2O content Range K content Range K2O content Range PN-EN 196-2:2013-11 pkt. 4.5.19. z wyłączeniem pkt. 4.5.19.5 | IB-DPA-27 wersja 09 z dnia 02-01-2026 r.","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","parameters_zh":[{"name":"范围","range":"(0,05 – 10,0) %"},{"name":"Zawartość równoważnika Na2O (z obliczeń) Zawartość Na"},{"name":"范围","range":"(0,05 – 5,0) %"},{"name":"Zawartość Na2O"},{"name":"范围","range":"(0,07 – 6,7) %"},{"name":"Zawartość K"},{"name":"范围","range":"(0,05 – 5,0) %"},{"name":"Zawartość K2O"},{"name":"范围","range":"(0,06 – 6,0) %"}],"search_zh":"电感耦合等离子体原子发射光谱法（ICP-OES） 依据气候部长关于废物目录的条例的废物代码。 范围 范围 范围 范围 范围 PN-EN 196-2:2013-11 pkt. 4.5.19. z wyłączeniem pkt. 4.5.19.5 | IB-DPA-27 wersja 09 z dnia 02-01-2026 r.","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。"},{"_id":"6a837a57af14b9c0e7b1fd93","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 24, 10 01 80, 10 01 82, Materiał budowlany: popiół lotny do betonu, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Popiół z torfu i drewna","methodology":"Zawartość MgO","parameters":[{"name":"Zakres","range":"(0,2 – 10,0) %"},{"name":"Zawartość Mg"},{"name":"Zakres","range":"(0,1 – 6,0) %"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość MgO\nZakres:\nZakres (0,2 – 10,0) %\nZawartość Mg\nZakres (0,1 – 6,0) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN 196-2:2013–11 pkt 4.5.2 z wyłączeniem pkt 4.5.13 | PN-EN 450-1:2012 pkt 5.2.1 | IB-DPA-25 wersja 08 z dnia 02-01-2026 r.","norm_bases":["PN-EN 196-2:2013–11 pkt 4.5.2 z wyłączeniem pkt 4.5.13","PN-EN 450-1:2012 pkt 5.2.1","IB-DPA-25 wersja 08 z dnia 02-01-2026 r."],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 24, 10 01 80, 10 01 82, Materiał budowlany: popiół lotny do betonu, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Popiół z torfu i drewna Zawartość MgO\nZakres:\nZakres (0,2 – 10,0) %\nZawartość Mg\nZakres (0,1 – 6,0) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN 196-2:2013–11 pkt 4.5.2 z wyłączeniem pkt 4.5.13 | PN-EN 450-1:2012 pkt 5.2.1 | IB-DPA-25 wersja 08 z dnia 02-01-2026 r. Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 24, 10 01 80, 10 01 82, Material budowlany: popiol lotny do betonu, Popiol, zuzel, Mieszanka popiolowo zuzlowa, Popiol z produktami odsiarczania - lotny, Popiol z produktami odsiarczania - fluidalny, Piaski ze zloz fluidalnych, Popiol z torfu i drewna Zawartosc MgO\nZakres:\nZakres (0,2 – 10,0) %\nZawartosc Mg\nZakres (0,1 – 6,0) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN 196-2:2013–11 pkt 4.5.2 z wylaczeniem pkt 4.5.13 | PN-EN 450-1:2012 pkt 5.2.1 | IB-DPA-25 wersja 08 z dnia 02-01-2026 r.","categories":["construction","environment","materials"],"row_index":70,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"MgO content","parameters_en":[{"name":"Range","range":"(0,2 – 10,0) %"},{"name":"Mg content"},{"name":"Range","range":"(0,1 – 6,0) %"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"MgO content Inductively coupled plasma optical emission spectrometry (ICP-OES) waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Range Mg content Range PN-EN 196-2:2013–11 pkt 4.5.2 z wyłączeniem pkt 4.5.13 | PN-EN 450-1:2012 pkt 5.2.1 | IB-DPA-25 wersja 08 z dnia 02-01-2026 r.","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","parameters_zh":[{"name":"范围","range":"(0,2 – 10,0) %"},{"name":"Zawartość Mg"},{"name":"范围","range":"(0,1 – 6,0) %"}],"search_zh":"电感耦合等离子体原子发射光谱法（ICP-OES） 依据气候部长关于废物目录的条例的废物代码。 范围 范围 PN-EN 196-2:2013–11 pkt 4.5.2 z wyłączeniem pkt 4.5.13 | PN-EN 450-1:2012 pkt 5.2.1 | IB-DPA-25 wersja 08 z dnia 02-01-2026 r.","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。"},{"_id":"6a837a57af14b9c0e7b1fd94","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 24, 10 01 80, 10 01 82, Materiał budowlany: popiół lotny do betonu, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Popiół z torfu i drewna","methodology":"Zawartość rozpuszczalnych fosforanów (V)","parameters":[{"name":"Zakres","range":"(1,0 – 200) mg/kg jako P2O5"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość rozpuszczalnych fosforanów (V)\nZakres (1,0 – 200) mg/kg jako P2O5\nMetoda spektrofotometryczna","reference":"PN-EN 450-1:2012 załącznik C","norm_bases":["PN-EN 450-1:2012 załącznik C"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 24, 10 01 80, 10 01 82, Materiał budowlany: popiół lotny do betonu, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Popiół z torfu i drewna Zawartość rozpuszczalnych fosforanów (V)\nZakres (1,0 – 200) mg/kg jako P2O5\nMetoda spektrofotometryczna PN-EN 450-1:2012 załącznik C Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 24, 10 01 80, 10 01 82, Material budowlany: popiol lotny do betonu, Popiol, zuzel, Mieszanka popiolowo zuzlowa, Popiol z produktami odsiarczania - lotny, Popiol z produktami odsiarczania - fluidalny, Piaski ze zloz fluidalnych, Popiol z torfu i drewna Zawartosc rozpuszczalnych fosforanow (V)\nZakres (1,0 – 200) mg/kg jako P2O5\nMetoda spektrofotometryczna PN-EN 450-1:2012 zalacznik C","categories":["construction","environment","materials"],"row_index":71,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of soluble phosphates (V)","parameters_en":[{"name":"Range","range":"(1,0 – 200) mg/kg jako P2O5"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Content of soluble phosphates (V) Spectrophotometric method waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Range PN-EN 450-1:2012 załącznik C","technique_en":"Spectrophotometric method","parameters_zh":[{"name":"范围","range":"(1,0 – 200) mg/kg jako P2O5"}],"search_zh":"分光光度法 依据气候部长关于废物目录的条例的废物代码。 范围 PN-EN 450-1:2012 załącznik C","technique_zh":"分光光度法","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。"},{"_id":"6a837a57af14b9c0e7b1fd95","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 24, 10 01 80, 10 01 82, Materiał budowlany: popiół lotny do betonu, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Popiół z torfu i drewna","methodology":"Suma Al2O3+Fe2O3+SiO2 całkowity (z obliczeń) Zawartość Al2O3","parameters":[{"name":"Zakres","range":"(5,0 – 40,0) %"},{"name":"Zawartość Al"},{"name":"Zakres","range":"(2,65 – 21,2) %"},{"name":"Zawartość Fe2O3"},{"name":"Zakres","range":"(1,0 – 30,0) %"},{"name":"Zawartość Fe"},{"name":"Zakres","range":"(0,70 – 21,0) %"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Suma Al2O3+Fe2O3+SiO2 całkowity (z obliczeń) Zawartość Al2O3\nZakres:\nZakres (5,0 – 40,0) %\nZawartość Al\nZakres (2,65 – 21,2) %\nZawartość Fe2O3\nZakres (1,0 – 30,0) %\nZawartość Fe\nZakres (0,70 – 21,0) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN 196-2:2013-11 pkt. 4.5.2 z wyłączeniem pkt. 4.5.10 i 4.5.11 | PN EN 450-1:2012 pkt 5.2.1 | IB-DPA-28 wersja 09 z dnia 02-01-2026 r.","norm_bases":["PN-EN 196-2:2013-11 pkt. 4.5.2 z wyłączeniem pkt. 4.5.10 i 4.5.11","PN EN 450-1:2012 pkt 5.2.1","IB-DPA-28 wersja 09 z dnia 02-01-2026 r."],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 24, 10 01 80, 10 01 82, Materiał budowlany: popiół lotny do betonu, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Popiół z torfu i drewna Suma Al2O3+Fe2O3+SiO2 całkowity (z obliczeń) Zawartość Al2O3\nZakres:\nZakres (5,0 – 40,0) %\nZawartość Al\nZakres (2,65 – 21,2) %\nZawartość Fe2O3\nZakres (1,0 – 30,0) %\nZawartość Fe\nZakres (0,70 – 21,0) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN 196-2:2013-11 pkt. 4.5.2 z wyłączeniem pkt. 4.5.10 i 4.5.11 | PN EN 450-1:2012 pkt 5.2.1 | IB-DPA-28 wersja 09 z dnia 02-01-2026 r. Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 24, 10 01 80, 10 01 82, Material budowlany: popiol lotny do betonu, Popiol, zuzel, Mieszanka popiolowo zuzlowa, Popiol z produktami odsiarczania - lotny, Popiol z produktami odsiarczania - fluidalny, Piaski ze zloz fluidalnych, Popiol z torfu i drewna Suma Al2O3+Fe2O3+SiO2 calkowity (z obliczen) Zawartosc Al2O3\nZakres:\nZakres (5,0 – 40,0) %\nZawartosc Al\nZakres (2,65 – 21,2) %\nZawartosc Fe2O3\nZakres (1,0 – 30,0) %\nZawartosc Fe\nZakres (0,70 – 21,0) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN 196-2:2013-11 pkt. 4.5.2 z wylaczeniem pkt. 4.5.10 i 4.5.11 | PN EN 450-1:2012 pkt 5.2.1 | IB-DPA-28 wersja 09 z dnia 02-01-2026 r.","categories":["construction","environment","materials"],"row_index":72,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of Al2O3+Fe2O3+SiO2 total (calculated) Al2O3 content","parameters_en":[{"name":"Range","range":"(5,0 – 40,0) %"},{"name":"Al content"},{"name":"Range","range":"(2,65 – 21,2) %"},{"name":"Fe2O3 content"},{"name":"Range","range":"(1,0 – 30,0) %"},{"name":"Fe content"},{"name":"Range","range":"(0,70 – 21,0) %"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Sum of Al2O3+Fe2O3+SiO2 total (calculated) Al2O3 content Inductively coupled plasma optical emission spectrometry (ICP-OES) waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Range Al content Range Fe2O3 content Range Fe content Range PN-EN 196-2:2013-11 pkt. 4.5.2 z wyłączeniem pkt. 4.5.10 i 4.5.11 | PN EN 450-1:2012 pkt 5.2.1 | IB-DPA-28 wersja 09 z dnia 02-01-2026 r.","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","parameters_zh":[{"name":"范围","range":"(5,0 – 40,0) %"},{"name":"Zawartość Al"},{"name":"范围","range":"(2,65 – 21,2) %"},{"name":"Zawartość Fe2O3"},{"name":"范围","range":"(1,0 – 30,0) %"},{"name":"Zawartość Fe"},{"name":"范围","range":"(0,70 – 21,0) %"}],"search_zh":"电感耦合等离子体原子发射光谱法（ICP-OES） 依据气候部长关于废物目录的条例的废物代码。 范围 范围 范围 范围 PN-EN 196-2:2013-11 pkt. 4.5.2 z wyłączeniem pkt. 4.5.10 i 4.5.11 | PN EN 450-1:2012 pkt 5.2.1 | IB-DPA-28 wersja 09 z dnia 02-01-2026 r.","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。"},{"_id":"6a837a57af14b9c0e7b1fd96","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 24, 10 01 80, 10 01 82, Materiał budowlany: popiół lotny do betonu, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Popiół z torfu i drewna","methodology":"Zawartość Si rozpuszczalny","parameters":[{"name":"Zakres","range":"(0,02 – 2,34) %"},{"name":"Zawartość SiO2 rozpuszczalny"},{"name":"Zakres","range":"(0,05 – 5,00) %"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość Si rozpuszczalny\nZakres:\nZakres (0,02 – 2,34) %\nZawartość SiO2 rozpuszczalny\nZakres (0,05 – 5,00) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN 196-2:2013-11 pkt.4.5.2 z wyłączeniem pkt. 4.5.8. | PN-EN 450-1:2012 pkt 5.2.1 | IB-DPA-28 wersja 09 z dnia 02-01-2026 r.","norm_bases":["PN-EN 196-2:2013-11 pkt.4.5.2 z wyłączeniem pkt. 4.5.8.","PN-EN 450-1:2012 pkt 5.2.1","IB-DPA-28 wersja 09 z dnia 02-01-2026 r."],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 24, 10 01 80, 10 01 82, Materiał budowlany: popiół lotny do betonu, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Popiół z torfu i drewna Zawartość Si rozpuszczalny\nZakres:\nZakres (0,02 – 2,34) %\nZawartość SiO2 rozpuszczalny\nZakres (0,05 – 5,00) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN 196-2:2013-11 pkt.4.5.2 z wyłączeniem pkt. 4.5.8. | PN-EN 450-1:2012 pkt 5.2.1 | IB-DPA-28 wersja 09 z dnia 02-01-2026 r. Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 24, 10 01 80, 10 01 82, Material budowlany: popiol lotny do betonu, Popiol, zuzel, Mieszanka popiolowo zuzlowa, Popiol z produktami odsiarczania - lotny, Popiol z produktami odsiarczania - fluidalny, Piaski ze zloz fluidalnych, Popiol z torfu i drewna Zawartosc Si rozpuszczalny\nZakres:\nZakres (0,02 – 2,34) %\nZawartosc SiO2 rozpuszczalny\nZakres (0,05 – 5,00) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN 196-2:2013-11 pkt.4.5.2 z wylaczeniem pkt. 4.5.8. | PN-EN 450-1:2012 pkt 5.2.1 | IB-DPA-28 wersja 09 z dnia 02-01-2026 r.","categories":["construction","environment","materials"],"row_index":73,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of soluble Si","parameters_en":[{"name":"Range","range":"(0,02 – 2,34) %"},{"name":"Content of soluble SiO2"},{"name":"Range","range":"(0,05 – 5,00) %"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Content of soluble Si Inductively coupled plasma optical emission spectrometry (ICP-OES) waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Range Content of soluble SiO2 Range PN-EN 196-2:2013-11 pkt.4.5.2 z wyłączeniem pkt. 4.5.8. | PN-EN 450-1:2012 pkt 5.2.1 | IB-DPA-28 wersja 09 z dnia 02-01-2026 r.","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","parameters_zh":[{"name":"范围","range":"(0,02 – 2,34) %"},{"name":"Zawartość SiO2 rozpuszczalny"},{"name":"范围","range":"(0,05 – 5,00) %"}],"search_zh":"电感耦合等离子体原子发射光谱法（ICP-OES） 依据气候部长关于废物目录的条例的废物代码。 范围 范围 PN-EN 196-2:2013-11 pkt.4.5.2 z wyłączeniem pkt. 4.5.8. | PN-EN 450-1:2012 pkt 5.2.1 | IB-DPA-28 wersja 09 z dnia 02-01-2026 r.","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。"},{"_id":"6a837a57af14b9c0e7b1fd97","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 24, 10 01 80, 10 01 82, Materiał budowlany: popiół lotny do betonu, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Popiół z torfu i drewna","methodology":"Zawartość czystego SiO2","parameters":[{"name":"Zakres","range":"(3,0 – 60,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość czystego SiO2\nZakres (3,0 – 60,0) %\nMetoda wagowa","reference":"PN-EN 196-2:2013-11 pkt.4.5.2 | PN-EN 450-1:2012 pkt 5.2.1","norm_bases":["PN-EN 196-2:2013-11 pkt.4.5.2","PN-EN 450-1:2012 pkt 5.2.1"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 24, 10 01 80, 10 01 82, Materiał budowlany: popiół lotny do betonu, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Popiół z torfu i drewna Zawartość czystego SiO2\nZakres (3,0 – 60,0) %\nMetoda wagowa PN-EN 196-2:2013-11 pkt.4.5.2 | PN-EN 450-1:2012 pkt 5.2.1 Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 24, 10 01 80, 10 01 82, Material budowlany: popiol lotny do betonu, Popiol, zuzel, Mieszanka popiolowo zuzlowa, Popiol z produktami odsiarczania - lotny, Popiol z produktami odsiarczania - fluidalny, Piaski ze zloz fluidalnych, Popiol z torfu i drewna Zawartosc czystego SiO2\nZakres (3,0 – 60,0) %\nMetoda wagowa PN-EN 196-2:2013-11 pkt.4.5.2 | PN-EN 450-1:2012 pkt 5.2.1","categories":["construction","environment","materials"],"row_index":74,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Pure SiO2 content","parameters_en":[{"name":"Range","range":"(3,0 – 60,0) %"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Pure SiO2 content Gravimetric method waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Range PN-EN 196-2:2013-11 pkt.4.5.2 | PN-EN 450-1:2012 pkt 5.2.1","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(3,0 – 60,0) %"}],"search_zh":"重量法 依据气候部长关于废物目录的条例的废物代码。 范围 PN-EN 196-2:2013-11 pkt.4.5.2 | PN-EN 450-1:2012 pkt 5.2.1","technique_zh":"重量法","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。"},{"_id":"6a837a57af14b9c0e7b1fd98","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 24, 10 01 80, 10 01 82, Materiał budowlany: popiół lotny do betonu, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Popiół z torfu i drewna","methodology":"Zawartość całkowitego SiO2 (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość całkowitego SiO2 (z obliczeń)","reference":"PN-EN 196-2:2013-11 pkt. 4.5.9","norm_bases":["PN-EN 196-2:2013-11 pkt. 4.5.9"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 24, 10 01 80, 10 01 82, Materiał budowlany: popiół lotny do betonu, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Popiół z torfu i drewna Zawartość całkowitego SiO2 (z obliczeń) PN-EN 196-2:2013-11 pkt. 4.5.9 Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 24, 10 01 80, 10 01 82, Material budowlany: popiol lotny do betonu, Popiol, zuzel, Mieszanka popiolowo zuzlowa, Popiol z produktami odsiarczania - lotny, Popiol z produktami odsiarczania - fluidalny, Piaski ze zloz fluidalnych, Popiol z torfu i drewna Zawartosc calkowitego SiO2 (z obliczen) PN-EN 196-2:2013-11 pkt. 4.5.9","categories":["construction","environment","materials"],"row_index":75,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total SiO2 content (calculated)","regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Total SiO2 content (calculated) waste codes according to the Regulation of the Minister of Climate on the waste catalogue. PN-EN 196-2:2013-11 pkt. 4.5.9","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。","search_zh":"依据气候部长关于废物目录的条例的废物代码。 PN-EN 196-2:2013-11 pkt. 4.5.9"},{"_id":"6a837a57af14b9c0e7b1fd99","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 24, 10 01 80, 10 01 82, Materiał budowlany: popiół lotny do betonu, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Popiół z torfu i drewna","methodology":"Zawartość CO2","parameters":[{"name":"Zakres","range":"(0,10 – 20,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość CO2\nZakres (0,10 – 20,0) %\nMetoda wagowa","reference":"PN-EN 196-2:2013-11 pkt. 4.5.17","norm_bases":["PN-EN 196-2:2013-11 pkt. 4.5.17"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 24, 10 01 80, 10 01 82, Materiał budowlany: popiół lotny do betonu, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Popiół z torfu i drewna Zawartość CO2\nZakres (0,10 – 20,0) %\nMetoda wagowa PN-EN 196-2:2013-11 pkt. 4.5.17 Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 24, 10 01 80, 10 01 82, Material budowlany: popiol lotny do betonu, Popiol, zuzel, Mieszanka popiolowo zuzlowa, Popiol z produktami odsiarczania - lotny, Popiol z produktami odsiarczania - fluidalny, Piaski ze zloz fluidalnych, Popiol z torfu i drewna Zawartosc CO2\nZakres (0,10 – 20,0) %\nMetoda wagowa PN-EN 196-2:2013-11 pkt. 4.5.17","categories":["construction","environment","materials"],"row_index":76,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"CO2 content","parameters_en":[{"name":"Range","range":"(0,10 – 20,0) %"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"CO2 content Gravimetric method waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Range PN-EN 196-2:2013-11 pkt. 4.5.17","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(0,10 – 20,0) %"}],"search_zh":"重量法 依据气候部长关于废物目录的条例的废物代码。 范围 PN-EN 196-2:2013-11 pkt. 4.5.17","technique_zh":"重量法","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。"},{"_id":"6a837a57af14b9c0e7b1fd9a","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 24, 10 01 80, 10 01 82, Materiał budowlany: popiół lotny do betonu, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Popiół z torfu i drewna","methodology":"Zawartość rtęci","parameters":[{"name":"Zakres","range":"(0,0010 – 0,800 ) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","techniques":["Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji"],"computed":[],"activity":"Zawartość rtęci\nZakres (0,0010 – 0,800 ) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","reference":"IB-DPA-09 wersja 04 z dnia 02-01-2026 r.","norm_bases":["IB-DPA-09 wersja 04 z dnia 02-01-2026 r."],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 24, 10 01 80, 10 01 82, Materiał budowlany: popiół lotny do betonu, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Popiół z torfu i drewna Zawartość rtęci\nZakres (0,0010 – 0,800 ) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji IB-DPA-09 wersja 04 z dnia 02-01-2026 r. Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 24, 10 01 80, 10 01 82, Material budowlany: popiol lotny do betonu, Popiol, zuzel, Mieszanka popiolowo zuzlowa, Popiol z produktami odsiarczania - lotny, Popiol z produktami odsiarczania - fluidalny, Piaski ze zloz fluidalnych, Popiol z torfu i drewna Zawartosc rteci\nZakres (0,0010 – 0,800 ) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z technika amalgamacji IB-DPA-09 wersja 04 z dnia 02-01-2026 r.","categories":["construction","environment","materials"],"row_index":77,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury content","parameters_en":[{"name":"Range","range":"(0,0010 – 0,800 ) mg/kg"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Mercury content Atomic absorption spectrometry with amalgamation technique waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Range IB-DPA-09 wersja 04 z dnia 02-01-2026 r.","technique_en":"Atomic absorption spectrometry with amalgamation technique","methodology_zh":"汞含量","parameters_zh":[{"name":"范围","range":"(0,0010 – 0,800 ) mg/kg"}],"search_zh":"汞含量 原子吸收光谱法（汞齐化技术） 依据气候部长关于废物目录的条例的废物代码。 范围 IB-DPA-09 wersja 04 z dnia 02-01-2026 r.","technique_zh":"原子吸收光谱法（汞齐化技术）","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。"},{"_id":"6a837a57af14b9c0e7b1fd9b","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Odpady kod: 10 01 02, 10 01 82, Materiał budowlany: popiół lotny do betonu","methodology":"Zawartość siarczanów VI jako SO3","parameters":[{"name":"Zakres","range":"(0,20 – 3,5) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość siarczanów VI jako SO3\nZakres (0,20 – 3,5) %\nMetoda wagowa","reference":"PN-EN 196-2:2013-11","norm_bases":["PN-EN 196-2:2013-11"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 10 01 02, 10 01 82, Materiał budowlany: popiół lotny do betonu Zawartość siarczanów VI jako SO3\nZakres (0,20 – 3,5) %\nMetoda wagowa PN-EN 196-2:2013-11 Odpady kod: 10 01 02, 10 01 82, Material budowlany: popiol lotny do betonu Zawartosc siarczanow VI jako SO3\nZakres (0,20 – 3,5) %\nMetoda wagowa PN-EN 196-2:2013-11","categories":["construction","environment","materials"],"row_index":78,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulphate VI content as SO3","parameters_en":[{"name":"Range","range":"(0,20 – 3,5) %"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Waste code: 10 01 02, 10 01 82, Construction material: fly ash for concrete Sulphate VI content as SO3 Gravimetric method waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Range PN-EN 196-2:2013-11","technique_en":"Gravimetric method","test_object_en":"Waste code: 10 01 02, 10 01 82, Construction material: fly ash for concrete","parameters_zh":[{"name":"范围","range":"(0,20 – 3,5) %"}],"search_zh":"重量法 依据气候部长关于废物目录的条例的废物代码。 范围 PN-EN 196-2:2013-11","technique_zh":"重量法","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。"},{"_id":"6a837a57af14b9c0e7b1fd9c","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Odpady kod: 10 01 02, 10 01 82, Materiał budowlany: popiół lotny do betonu","methodology":"Zawartość tlenków:","parameters":[{"name":"SiO2","range":"(24,4 – 74,0) %"},{"name":"Fe2O3","range":"(1,60 – 15,0) %"},{"name":"Al2O3","range":"(2,50 – 35,0) %"},{"name":"TiO2","range":"(0,11 – 1,65) %"},{"name":"CaO","range":"(2,54 – 32,6) %"},{"name":"MgO","range":"(0,90 – 3,50) %"},{"name":"K2O","range":"(0,45 – 4,81) %"},{"name":"Na2O","range":"(0,14 – 3,20) %"},{"name":"P2O5","range":"(0,060 – 1,50) %"}],"technique":"Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali","techniques":["Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali"],"computed":[],"activity":"Zawartość tlenków:\nZakres:\nSiO2 (24,4 – 74,0) %\nFe2O3 (1,60 – 15,0) %\nAl2O3 (2,50 – 35,0) %\nTiO2 (0,11 – 1,65) %\nCaO (2,54 – 32,6) %\nMgO (0,90 – 3,50) %\nK2O (0,45 – 4,81) %\nNa2O (0,14 – 3,20) %\nP2O5 (0,060 – 1,50) %\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali","reference":"PN-EN 196-2:2013-11 p. 5","norm_bases":["PN-EN 196-2:2013-11 p. 5"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 10 01 02, 10 01 82, Materiał budowlany: popiół lotny do betonu Zawartość tlenków:\nZakres:\nSiO2 (24,4 – 74,0) %\nFe2O3 (1,60 – 15,0) %\nAl2O3 (2,50 – 35,0) %\nTiO2 (0,11 – 1,65) %\nCaO (2,54 – 32,6) %\nMgO (0,90 – 3,50) %\nK2O (0,45 – 4,81) %\nNa2O (0,14 – 3,20) %\nP2O5 (0,060 – 1,50) %\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali PN-EN 196-2:2013-11 p. 5 Odpady kod: 10 01 02, 10 01 82, Material budowlany: popiol lotny do betonu Zawartosc tlenkow:\nZakres:\nSiO2 (24,4 – 74,0) %\nFe2O3 (1,60 – 15,0) %\nAl2O3 (2,50 – 35,0) %\nTiO2 (0,11 – 1,65) %\nCaO (2,54 – 32,6) %\nMgO (0,90 – 3,50) %\nK2O (0,45 – 4,81) %\nNa2O (0,14 – 3,20) %\nP2O5 (0,060 – 1,50) %\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersja fali PN-EN 196-2:2013-11 p. 5","categories":["construction","environment","materials"],"row_index":79,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of oxides:","parameters_en":[{"name":"SiO2","range":"(24,4 – 74,0) %"},{"name":"Fe2O3","range":"(1,60 – 15,0) %"},{"name":"Al2O3","range":"(2,50 – 35,0) %"},{"name":"TiO2","range":"(0,11 – 1,65) %"},{"name":"CaO","range":"(2,54 – 32,6) %"},{"name":"MgO","range":"(0,90 – 3,50) %"},{"name":"K2O","range":"(0,45 – 4,81) %"},{"name":"Na2O","range":"(0,14 – 3,20) %"},{"name":"P2O5","range":"(0,060 – 1,50) %"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Waste code: 10 01 02, 10 01 82, Construction material: fly ash for concrete Content of oxides: Wavelength-dispersive X-ray fluorescence spectrometry waste codes according to the Regulation of the Minister of Climate on the waste catalogue. SiO2 Fe2O3 Al2O3 TiO2 CaO MgO K2O Na2O P2O5 PN-EN 196-2:2013-11 p. 5","technique_en":"Wavelength-dispersive X-ray fluorescence spectrometry","test_object_en":"Waste code: 10 01 02, 10 01 82, Construction material: fly ash for concrete","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。","search_zh":"波长色散X射线荧光光谱法 依据气候部长关于废物目录的条例的废物代码。 SiO2 Fe2O3 Al2O3 TiO2 CaO MgO K2O Na2O P2O5 PN-EN 196-2:2013-11 p. 5","parameters_zh":[{"name":"SiO2","range":"(24,4 – 74,0) %"},{"name":"Fe2O3","range":"(1,60 – 15,0) %"},{"name":"Al2O3","range":"(2,50 – 35,0) %"},{"name":"TiO2","range":"(0,11 – 1,65) %"},{"name":"CaO","range":"(2,54 – 32,6) %"},{"name":"MgO","range":"(0,90 – 3,50) %"},{"name":"K2O","range":"(0,45 – 4,81) %"},{"name":"Na2O","range":"(0,14 – 3,20) %"},{"name":"P2O5","range":"(0,060 – 1,50) %"}],"technique_zh":"波长色散X射线荧光光谱法"},{"_id":"6a837a57af14b9c0e7b1fd9d","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Odpady kod: 10 01 02, Materiał budowlany: popiół lotny do betonu","methodology":"Zawartość chlorków","parameters":[{"name":"Zakres","range":"(0,001 – 0,2) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość chlorków\nZakres (0,001 – 0,2) %\nMetoda miareczkowa","reference":"PN-EN 196-2:2013-11","norm_bases":["PN-EN 196-2:2013-11"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 10 01 02, Materiał budowlany: popiół lotny do betonu Zawartość chlorków\nZakres (0,001 – 0,2) %\nMetoda miareczkowa PN-EN 196-2:2013-11 Odpady kod: 10 01 02, Material budowlany: popiol lotny do betonu Zawartosc chlorkow\nZakres (0,001 – 0,2) %\nMetoda miareczkowa PN-EN 196-2:2013-11","categories":["construction","environment","materials"],"row_index":80,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride content","parameters_en":[{"name":"Range","range":"(0,001 – 0,2) %"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Waste code: 10 01 02, Construction material: fly ash for concrete Chloride content Titrimetric method waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Range PN-EN 196-2:2013-11","technique_en":"Titrimetric method","test_object_en":"Waste code: 10 01 02, Construction material: fly ash for concrete","parameters_zh":[{"name":"范围","range":"(0,001 – 0,2) %"}],"search_zh":"氯化物含量 滴定法 依据气候部长关于废物目录的条例的废物代码。 范围 PN-EN 196-2:2013-11","technique_zh":"滴定法","methodology_zh":"氯化物含量","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。"},{"_id":"6a837a57af14b9c0e7b1fd9e","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Odpady kod: 10 01 01, 10 01 03, 10 01 05, 10 01 24, 10 01 80, 10 01 82, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Produkt odsiarczania, Popiół z torfu i drewna","methodology":"Zawartość chlorków","parameters":[{"name":"Zakres","range":"(0,001 – 9,0) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość chlorków\nZakres (0,001 – 9,0) %\nMetoda miareczkowa","reference":"PN-EN 196-2:2013-11","norm_bases":["PN-EN 196-2:2013-11"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 10 01 01, 10 01 03, 10 01 05, 10 01 24, 10 01 80, 10 01 82, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Produkt odsiarczania, Popiół z torfu i drewna Zawartość chlorków\nZakres (0,001 – 9,0) %\nMetoda miareczkowa PN-EN 196-2:2013-11 Odpady kod: 10 01 01, 10 01 03, 10 01 05, 10 01 24, 10 01 80, 10 01 82, Popiol, zuzel, Mieszanka popiolowo zuzlowa, Popiol z produktami odsiarczania - lotny, Popiol z produktami odsiarczania - fluidalny, Piaski ze zloz fluidalnych, Produkt odsiarczania, Popiol z torfu i drewna Zawartosc chlorkow\nZakres (0,001 – 9,0) %\nMetoda miareczkowa PN-EN 196-2:2013-11","categories":["environment"],"row_index":81,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride content","parameters_en":[{"name":"Range","range":"(0,001 – 9,0) %"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Chloride content Titrimetric method waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Range PN-EN 196-2:2013-11","technique_en":"Titrimetric method","parameters_zh":[{"name":"范围","range":"(0,001 – 9,0) %"}],"search_zh":"氯化物含量 滴定法 依据气候部长关于废物目录的条例的废物代码。 范围 PN-EN 196-2:2013-11","technique_zh":"滴定法","methodology_zh":"氯化物含量","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。"},{"_id":"6a837a57af14b9c0e7b1fd9f","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Odpady kod: 10 01 05, 10 01 19, 10 01 21, 10 01 25, 10 01 26, 19 09 02, 19 09 03, 19 09 04, Popiół, żużel, Produkt odsiarczania","methodology":"Zawartość wolnego tlenku wapnia CaO","parameters":[{"name":"Zakres","range":"(0,01 – 20,0) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość wolnego tlenku wapnia CaO\nZakres (0,01 – 20,0) %\nMetoda miareczkowa","reference":"PN-EN 451-1:2017-06","norm_bases":["PN-EN 451-1:2017-06"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 10 01 05, 10 01 19, 10 01 21, 10 01 25, 10 01 26, 19 09 02, 19 09 03, 19 09 04, Popiół, żużel, Produkt odsiarczania Zawartość wolnego tlenku wapnia CaO\nZakres (0,01 – 20,0) %\nMetoda miareczkowa PN-EN 451-1:2017-06 Odpady kod: 10 01 05, 10 01 19, 10 01 21, 10 01 25, 10 01 26, 19 09 02, 19 09 03, 19 09 04, Popiol, zuzel, Produkt odsiarczania Zawartosc wolnego tlenku wapnia CaO\nZakres (0,01 – 20,0) %\nMetoda miareczkowa PN-EN 451-1:2017-06","categories":["environment"],"row_index":82,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free calcium oxide CaO content","parameters_en":[{"name":"Range","range":"(0,01 – 20,0) %"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Free calcium oxide CaO content Titrimetric method waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Range PN-EN 451-1:2017-06","technique_en":"Titrimetric method","parameters_zh":[{"name":"范围","range":"(0,01 – 20,0) %"}],"search_zh":"游离氧化钙 CaO 含量 滴定法 依据气候部长关于废物目录的条例的废物代码。 范围 PN-EN 451-1:2017-06","technique_zh":"滴定法","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。","methodology_zh":"游离氧化钙 CaO 含量"},{"_id":"6a837a57af14b9c0e7b1fda0","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Odpady kod: 10 01 05, 10 01 19, 10 01 21, 10 01 25, 10 01 26, 19 09 02, 19 09 03, 19 09 04, Popiół, żużel, Produkt odsiarczania","methodology":"Straty prażenia","parameters":[{"name":"Zakres","range":"(0,20 – 35,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Straty prażenia\nZakres (0,20 – 35,0) %\nMetoda wagowa","reference":"PN-EN 196-2:2013 -11 | PN-EN 450-1:2012","norm_bases":["PN-EN 196-2:2013 -11","PN-EN 450-1:2012"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 10 01 05, 10 01 19, 10 01 21, 10 01 25, 10 01 26, 19 09 02, 19 09 03, 19 09 04, Popiół, żużel, Produkt odsiarczania Straty prażenia\nZakres (0,20 – 35,0) %\nMetoda wagowa PN-EN 196-2:2013 -11 | PN-EN 450-1:2012 Odpady kod: 10 01 05, 10 01 19, 10 01 21, 10 01 25, 10 01 26, 19 09 02, 19 09 03, 19 09 04, Popiol, zuzel, Produkt odsiarczania Straty prazenia\nZakres (0,20 – 35,0) %\nMetoda wagowa PN-EN 196-2:2013 -11 | PN-EN 450-1:2012","categories":["environment"],"row_index":83,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Loss on ignition","parameters_en":[{"name":"Range","range":"(0,20 – 35,0) %"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Loss on ignition Gravimetric method waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Range PN-EN 196-2:2013 -11 | PN-EN 450-1:2012","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(0,20 – 35,0) %"}],"search_zh":"烧失量 重量法 依据气候部长关于废物目录的条例的废物代码。 范围 PN-EN 196-2:2013 -11 | PN-EN 450-1:2012","technique_zh":"重量法","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。","methodology_zh":"烧失量"},{"_id":"6a837a57af14b9c0e7b1fda1","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Odpady kod: 10 01 05, 10 01 19, 10 01 21, 10 01 25, 10 01 26, 19 09 02, 19 09 03, 19 09 04, Popiół, żużel, Produkt odsiarczania","methodology":"Zawartość siarki całkowitej","parameters":[{"name":"Zakres","range":"(0,005 – 17,00) %"},{"name":"Zawartość SO3 (z obliczeń)"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość siarki całkowitej\nZakres:\nZakres (0,005 – 17,00) %\nZawartość SO3 (z obliczeń)\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04584:2001","norm_bases":["PN-G-04584:2001"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 10 01 05, 10 01 19, 10 01 21, 10 01 25, 10 01 26, 19 09 02, 19 09 03, 19 09 04, Popiół, żużel, Produkt odsiarczania Zawartość siarki całkowitej\nZakres:\nZakres (0,005 – 17,00) %\nZawartość SO3 (z obliczeń)\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04584:2001 Odpady kod: 10 01 05, 10 01 19, 10 01 21, 10 01 25, 10 01 26, 19 09 02, 19 09 03, 19 09 04, Popiol, zuzel, Produkt odsiarczania Zawartosc siarki calkowitej\nZakres:\nZakres (0,005 – 17,00) %\nZawartosc SO3 (z obliczen)\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04584:2001","categories":["environment"],"row_index":84,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total sulfur content","parameters_en":[{"name":"Range","range":"(0,005 – 17,00) %"},{"name":"SO3 content (calculated)"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Total sulfur content High-temperature combustion with IR detection waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Range SO3 content (calculated) PN-G-04584:2001","technique_en":"High-temperature combustion with IR detection","methodology_zh":"全硫含量","parameters_zh":[{"name":"范围","range":"(0,005 – 17,00) %"},{"name":"Zawartość SO3 (z obliczeń)"}],"search_zh":"全硫含量 高温燃烧红外检测法 依据气候部长关于废物目录的条例的废物代码。 范围 PN-G-04584:2001","technique_zh":"高温燃烧红外检测法","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。"},{"_id":"6a837a57af14b9c0e7b1fda2","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Odpady kod: 10 01 05, 10 01 19, 10 01 21, 10 01 25, 10 01 26, 19 09 02, 19 09 03, 19 09 04, Popiół, żużel, Produkt odsiarczania","methodology":"Zawartość węgla całkowitego","parameters":[{"name":"Zakres","range":"(0,10 – 50,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość węgla całkowitego\nZakres (0,10 – 50,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"IB-DPA-23 wersja 08 z dnia 02-01-2026 r.","norm_bases":["IB-DPA-23 wersja 08 z dnia 02-01-2026 r."],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 10 01 05, 10 01 19, 10 01 21, 10 01 25, 10 01 26, 19 09 02, 19 09 03, 19 09 04, Popiół, żużel, Produkt odsiarczania Zawartość węgla całkowitego\nZakres (0,10 – 50,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR IB-DPA-23 wersja 08 z dnia 02-01-2026 r. Odpady kod: 10 01 05, 10 01 19, 10 01 21, 10 01 25, 10 01 26, 19 09 02, 19 09 03, 19 09 04, Popiol, zuzel, Produkt odsiarczania Zawartosc wegla calkowitego\nZakres (0,10 – 50,00) %\nMetoda wysokotemperaturowego spalania z detekcja IR IB-DPA-23 wersja 08 z dnia 02-01-2026 r.","categories":["environment"],"row_index":85,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total carbon content","parameters_en":[{"name":"Range","range":"(0,10 – 50,00) %"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Total carbon content High-temperature combustion with IR detection waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Range IB-DPA-23 wersja 08 z dnia 02-01-2026 r.","technique_en":"High-temperature combustion with IR detection","methodology_zh":"总碳含量","parameters_zh":[{"name":"范围","range":"(0,10 – 50,00) %"}],"search_zh":"总碳含量 高温燃烧红外检测法 依据气候部长关于废物目录的条例的废物代码。 范围 IB-DPA-23 wersja 08 z dnia 02-01-2026 r.","technique_zh":"高温燃烧红外检测法","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。"},{"_id":"6a837a57af14b9c0e7b1fda3","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Odpady kod: 10 01 05, 10 01 19, 10 01 21, 10 01 25, 10 01 26, 19 09 02, 19 09 03, 19 09 04, Popiół, żużel, Produkt odsiarczania","methodology":"Zawartość reaktywnego CaO (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość reaktywnego CaO (z obliczeń)","reference":"PN-EN 197-1:2012","norm_bases":["PN-EN 197-1:2012"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 10 01 05, 10 01 19, 10 01 21, 10 01 25, 10 01 26, 19 09 02, 19 09 03, 19 09 04, Popiół, żużel, Produkt odsiarczania Zawartość reaktywnego CaO (z obliczeń) PN-EN 197-1:2012 Odpady kod: 10 01 05, 10 01 19, 10 01 21, 10 01 25, 10 01 26, 19 09 02, 19 09 03, 19 09 04, Popiol, zuzel, Produkt odsiarczania Zawartosc reaktywnego CaO (z obliczen) PN-EN 197-1:2012","categories":["environment"],"row_index":86,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Reactive CaO content (calculated)","regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Reactive CaO content (calculated) waste codes according to the Regulation of the Minister of Climate on the waste catalogue. PN-EN 197-1:2012","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。","search_zh":"依据气候部长关于废物目录的条例的废物代码。 PN-EN 197-1:2012"},{"_id":"6a837a57af14b9c0e7b1fda4","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Odpady kod: 10 01 05, 10 01 19, 10 01 21, 10 01 25, 10 01 26, 19 09 02, 19 09 03, 19 09 04, Popiół, żużel, Produkt odsiarczania","methodology":"Zawartość CaO","parameters":[{"name":"Zakres","range":"(0,1 – 21,0) %"},{"name":"Zawartość Ca"},{"name":"Zakres","range":"(0,1 – 15,0) %"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość CaO\nZakres:\nZakres (0,1 – 21,0) %\nZawartość Ca\nZakres (0,1 – 15,0) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN 196-2:2013-11 pkt 4.5.2 z wyłączeniem pkt. 4.5.12 | PN-EN 450-1:2012 pkt 5.2.1 | IB-DPA-25 wersja 08 z dnia 02-01-2026 r.","norm_bases":["PN-EN 196-2:2013-11 pkt 4.5.2 z wyłączeniem pkt. 4.5.12","PN-EN 450-1:2012 pkt 5.2.1","IB-DPA-25 wersja 08 z dnia 02-01-2026 r."],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 10 01 05, 10 01 19, 10 01 21, 10 01 25, 10 01 26, 19 09 02, 19 09 03, 19 09 04, Popiół, żużel, Produkt odsiarczania Zawartość CaO\nZakres:\nZakres (0,1 – 21,0) %\nZawartość Ca\nZakres (0,1 – 15,0) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN 196-2:2013-11 pkt 4.5.2 z wyłączeniem pkt. 4.5.12 | PN-EN 450-1:2012 pkt 5.2.1 | IB-DPA-25 wersja 08 z dnia 02-01-2026 r. Odpady kod: 10 01 05, 10 01 19, 10 01 21, 10 01 25, 10 01 26, 19 09 02, 19 09 03, 19 09 04, Popiol, zuzel, Produkt odsiarczania Zawartosc CaO\nZakres:\nZakres (0,1 – 21,0) %\nZawartosc Ca\nZakres (0,1 – 15,0) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN 196-2:2013-11 pkt 4.5.2 z wylaczeniem pkt. 4.5.12 | PN-EN 450-1:2012 pkt 5.2.1 | IB-DPA-25 wersja 08 z dnia 02-01-2026 r.","categories":["environment"],"row_index":87,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"CaO content","parameters_en":[{"name":"Range","range":"(0,1 – 21,0) %"},{"name":"Ca content"},{"name":"Range","range":"(0,1 – 15,0) %"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"CaO content Inductively coupled plasma optical emission spectrometry (ICP-OES) waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Range Ca content Range PN-EN 196-2:2013-11 pkt 4.5.2 z wyłączeniem pkt. 4.5.12 | PN-EN 450-1:2012 pkt 5.2.1 | IB-DPA-25 wersja 08 z dnia 02-01-2026 r.","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","parameters_zh":[{"name":"范围","range":"(0,1 – 21,0) %"},{"name":"Zawartość Ca"},{"name":"范围","range":"(0,1 – 15,0) %"}],"search_zh":"CaO 含量 电感耦合等离子体原子发射光谱法（ICP-OES） 依据气候部长关于废物目录的条例的废物代码。 范围 范围 PN-EN 196-2:2013-11 pkt 4.5.2 z wyłączeniem pkt. 4.5.12 | PN-EN 450-1:2012 pkt 5.2.1 | IB-DPA-25 wersja 08 z dnia 02-01-2026 r.","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。","methodology_zh":"CaO 含量"},{"_id":"6a837a57af14b9c0e7b1fda5","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Odpady kod: 10 01 05, 10 01 19, 10 01 21, 10 01 25, 10 01 26, 19 09 02, 19 09 03, 19 09 04, Popiół, żużel, Produkt odsiarczania","methodology":"Zawartość CO2","parameters":[{"name":"Zakres","range":"(0,10 – 20,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość CO2\nZakres (0,10 – 20,0) %\nMetoda wagowa","reference":"PN-EN 196-2:2013-11 pkt. 4.5.17","norm_bases":["PN-EN 196-2:2013-11 pkt. 4.5.17"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 10 01 05, 10 01 19, 10 01 21, 10 01 25, 10 01 26, 19 09 02, 19 09 03, 19 09 04, Popiół, żużel, Produkt odsiarczania Zawartość CO2\nZakres (0,10 – 20,0) %\nMetoda wagowa PN-EN 196-2:2013-11 pkt. 4.5.17 Odpady kod: 10 01 05, 10 01 19, 10 01 21, 10 01 25, 10 01 26, 19 09 02, 19 09 03, 19 09 04, Popiol, zuzel, Produkt odsiarczania Zawartosc CO2\nZakres (0,10 – 20,0) %\nMetoda wagowa PN-EN 196-2:2013-11 pkt. 4.5.17","categories":["environment"],"row_index":88,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"CO2 content","parameters_en":[{"name":"Range","range":"(0,10 – 20,0) %"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"CO2 content Gravimetric method waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Range PN-EN 196-2:2013-11 pkt. 4.5.17","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(0,10 – 20,0) %"}],"search_zh":"重量法 依据气候部长关于废物目录的条例的废物代码。 范围 PN-EN 196-2:2013-11 pkt. 4.5.17","technique_zh":"重量法","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。"},{"_id":"6a837a57af14b9c0e7b1fda6","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Odpady kod: 10 01 05, 10 01 19, 10 01 21, 10 01 25, 10 01 26, 19 09 02, 19 09 03, 19 09 04, Popiół, żużel, Produkt odsiarczania","methodology":"Zawartość rtęci","parameters":[{"name":"Zakres","range":"(0,0010 – 0,800 ) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","techniques":["Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji"],"computed":[],"activity":"Zawartość rtęci\nZakres (0,0010 – 0,800 ) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","reference":"IB-DPA-09 wersja 04 z dnia 02-01-2026 r.","norm_bases":["IB-DPA-09 wersja 04 z dnia 02-01-2026 r."],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 10 01 05, 10 01 19, 10 01 21, 10 01 25, 10 01 26, 19 09 02, 19 09 03, 19 09 04, Popiół, żużel, Produkt odsiarczania Zawartość rtęci\nZakres (0,0010 – 0,800 ) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji IB-DPA-09 wersja 04 z dnia 02-01-2026 r. Odpady kod: 10 01 05, 10 01 19, 10 01 21, 10 01 25, 10 01 26, 19 09 02, 19 09 03, 19 09 04, Popiol, zuzel, Produkt odsiarczania Zawartosc rteci\nZakres (0,0010 – 0,800 ) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z technika amalgamacji IB-DPA-09 wersja 04 z dnia 02-01-2026 r.","categories":["environment"],"row_index":89,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury content","parameters_en":[{"name":"Range","range":"(0,0010 – 0,800 ) mg/kg"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Mercury content Atomic absorption spectrometry with amalgamation technique waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Range IB-DPA-09 wersja 04 z dnia 02-01-2026 r.","technique_en":"Atomic absorption spectrometry with amalgamation technique","methodology_zh":"汞含量","parameters_zh":[{"name":"范围","range":"(0,0010 – 0,800 ) mg/kg"}],"search_zh":"汞含量 原子吸收光谱法（汞齐化技术） 依据气候部长关于废物目录的条例的废物代码。 范围 IB-DPA-09 wersja 04 z dnia 02-01-2026 r.","technique_zh":"原子吸收光谱法（汞齐化技术）","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。"},{"_id":"6a837a57af14b9c0e7b1fda7","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Odpady kod: 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 21, 10 01 24, 10 01 25, 10 01 26, 10 01 80, 10 01 82 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 05 04, 17 06 04, 17 09 04, 19 08 05, 19 09 02, 19 09 03, 19 09 04, 20 02 01, Materiał budowlany: popiół lotny do betonu, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania – lotny, Popiół z produktami odsiarczania – fluidalny, Piaski ze złóż fluidalnych, Produkt odsiarczania, Popiół z torfu i drewna","methodology":"Zawartość wody","parameters":[{"name":"Zakres","range":"(0,10 – 98,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wody\nZakres (0,10 – 98,0) %\nMetoda wagowa","reference":"PN-EN 12457-4:2006 | PN-EN 12880:2004","norm_bases":["PN-EN 12457-4:2006","PN-EN 12880:2004"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 21, 10 01 24, 10 01 25, 10 01 26, 10 01 80, 10 01 82 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 05 04, 17 06 04, 17 09 04, 19 08 05, 19 09 02, 19 09 03, 19 09 04, 20 02 01, Materiał budowlany: popiół lotny do betonu, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania – lotny, Popiół z produktami odsiarczania – fluidalny, Piaski ze złóż fluidalnych, Produkt odsiarczania, Popiół z torfu i drewna Zawartość wody\nZakres (0,10 – 98,0) %\nMetoda wagowa PN-EN 12457-4:2006 | PN-EN 12880:2004 Odpady kod: 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 21, 10 01 24, 10 01 25, 10 01 26, 10 01 80, 10 01 82 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 05 04, 17 06 04, 17 09 04, 19 08 05, 19 09 02, 19 09 03, 19 09 04, 20 02 01, Material budowlany: popiol lotny do betonu, Popiol, zuzel, Mieszanka popiolowo zuzlowa, Popiol z produktami odsiarczania – lotny, Popiol z produktami odsiarczania – fluidalny, Piaski ze zloz fluidalnych, Produkt odsiarczania, Popiol z torfu i drewna Zawartosc wody\nZakres (0,10 – 98,0) %\nMetoda wagowa PN-EN 12457-4:2006 | PN-EN 12880:2004","categories":["construction","environment","water","materials"],"row_index":90,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water content","parameters_en":[{"name":"Range","range":"(0,10 – 98,0) %"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Water content Gravimetric method waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Range PN-EN 12457-4:2006 | PN-EN 12880:2004","technique_en":"Gravimetric method","methodology_zh":"水分含量","parameters_zh":[{"name":"范围","range":"(0,10 – 98,0) %"}],"search_zh":"水分含量 重量法 依据气候部长关于废物目录的条例的废物代码。 范围 PN-EN 12457-4:2006 | PN-EN 12880:2004","technique_zh":"重量法","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。"},{"_id":"6a837a57af14b9c0e7b1fda8","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 21, 10 01 24, 10 01 25, 10 01 26, 10 01 80, 10 01 82, 19 09 02, 19 09 03, 19 09 04, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania – lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Produkt odsiarczania, Popiół z torfu i drewna","methodology":"Strata prażenia (części palne)","parameters":[{"name":"Zakres","range":"(0,10 – 65,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Strata prażenia (części palne)\nZakres (0,10 – 65,0) %\nMetoda wagowa","reference":"PN-77/G-04528.02","norm_bases":["PN-77/G-04528.02"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 21, 10 01 24, 10 01 25, 10 01 26, 10 01 80, 10 01 82, 19 09 02, 19 09 03, 19 09 04, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania – lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Produkt odsiarczania, Popiół z torfu i drewna Strata prażenia (części palne)\nZakres (0,10 – 65,0) %\nMetoda wagowa PN-77/G-04528.02 Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 21, 10 01 24, 10 01 25, 10 01 26, 10 01 80, 10 01 82, 19 09 02, 19 09 03, 19 09 04, Popiol, zuzel, Mieszanka popiolowo zuzlowa, Popiol z produktami odsiarczania – lotny, Popiol z produktami odsiarczania - fluidalny, Piaski ze zloz fluidalnych, Produkt odsiarczania, Popiol z torfu i drewna Strata prazenia (czesci palne)\nZakres (0,10 – 65,0) %\nMetoda wagowa PN-77/G-04528.02","categories":["environment"],"row_index":91,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Loss on ignition (combustible matter)","parameters_en":[{"name":"Range","range":"(0,10 – 65,0) %"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Loss on ignition (combustible matter) Gravimetric method waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Range PN-77/G-04528.02","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(0,10 – 65,0) %"}],"search_zh":"烧失量（可燃组分） 重量法 依据气候部长关于废物目录的条例的废物代码。 范围 PN-77/G-04528.02","technique_zh":"重量法","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。","methodology_zh":"烧失量（可燃组分）"},{"_id":"6a837a57af14b9c0e7b1fda9","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 21, 10 01 24, 10 01 25, 10 01 26, 10 01 80, 10 01 82, 19 09 02, 19 09 03, 19 09 04, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania – lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Produkt odsiarczania, Popiół z torfu i drewna","methodology":"Strata prażenia (części palne)","parameters":[{"name":"Zakres","range":"(0,05 – 65,00) %"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)"],"computed":[],"activity":"Strata prażenia (części palne)\nZakres (0,05 – 65,00) %\nMetoda termograwimetryczna (TGA)","reference":"IB-DPA-24 wersja 07 z dnia 02-01-2026 r.","norm_bases":["IB-DPA-24 wersja 07 z dnia 02-01-2026 r."],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 21, 10 01 24, 10 01 25, 10 01 26, 10 01 80, 10 01 82, 19 09 02, 19 09 03, 19 09 04, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania – lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Produkt odsiarczania, Popiół z torfu i drewna Strata prażenia (części palne)\nZakres (0,05 – 65,00) %\nMetoda termograwimetryczna (TGA) IB-DPA-24 wersja 07 z dnia 02-01-2026 r. Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 21, 10 01 24, 10 01 25, 10 01 26, 10 01 80, 10 01 82, 19 09 02, 19 09 03, 19 09 04, Popiol, zuzel, Mieszanka popiolowo zuzlowa, Popiol z produktami odsiarczania – lotny, Popiol z produktami odsiarczania - fluidalny, Piaski ze zloz fluidalnych, Produkt odsiarczania, Popiol z torfu i drewna Strata prazenia (czesci palne)\nZakres (0,05 – 65,00) %\nMetoda termograwimetryczna (TGA) IB-DPA-24 wersja 07 z dnia 02-01-2026 r.","categories":["environment"],"row_index":92,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Loss on ignition (combustible matter)","parameters_en":[{"name":"Range","range":"(0,05 – 65,00) %"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Loss on ignition (combustible matter) Thermogravimetric method (TGA) waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Range IB-DPA-24 wersja 07 z dnia 02-01-2026 r.","technique_en":"Thermogravimetric method (TGA)","parameters_zh":[{"name":"范围","range":"(0,05 – 65,00) %"}],"search_zh":"烧失量（可燃组分） 热重法（TGA） 依据气候部长关于废物目录的条例的废物代码。 范围 IB-DPA-24 wersja 07 z dnia 02-01-2026 r.","technique_zh":"热重法（TGA）","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。","methodology_zh":"烧失量（可燃组分）"},{"_id":"6a837a57af14b9c0e7b1fdaa","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 21, 10 01 24, 10 01 25, 10 01 26, 10 01 80, 10 01 82, 19 09 02, 19 09 03, 19 09 04, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania – lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Produkt odsiarczania, Popiół z torfu i drewna","methodology":"Straty przy prażeniu suchej masy","parameters":[{"name":"Zakres","range":"(0,5 – 80,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Straty przy prażeniu suchej masy\nZakres (0,5 – 80,0) %\nMetoda wagowa","reference":"PN-EN 15169:2011+Ap1:2012","norm_bases":["PN-EN 15169:2011+Ap1:2012"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 21, 10 01 24, 10 01 25, 10 01 26, 10 01 80, 10 01 82, 19 09 02, 19 09 03, 19 09 04, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania – lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Produkt odsiarczania, Popiół z torfu i drewna Straty przy prażeniu suchej masy\nZakres (0,5 – 80,0) %\nMetoda wagowa PN-EN 15169:2011+Ap1:2012 Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 21, 10 01 24, 10 01 25, 10 01 26, 10 01 80, 10 01 82, 19 09 02, 19 09 03, 19 09 04, Popiol, zuzel, Mieszanka popiolowo zuzlowa, Popiol z produktami odsiarczania – lotny, Popiol z produktami odsiarczania - fluidalny, Piaski ze zloz fluidalnych, Produkt odsiarczania, Popiol z torfu i drewna Straty przy prazeniu suchej masy\nZakres (0,5 – 80,0) %\nMetoda wagowa PN-EN 15169:2011+Ap1:2012","categories":["environment"],"row_index":93,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Loss on ignition of dry matter","parameters_en":[{"name":"Range","range":"(0,5 – 80,0) %"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Loss on ignition of dry matter Gravimetric method waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Range PN-EN 15169:2011+Ap1:2012","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(0,5 – 80,0) %"}],"search_zh":"干物质烧失量 重量法 依据气候部长关于废物目录的条例的废物代码。 范围 PN-EN 15169:2011+Ap1:2012","technique_zh":"重量法","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。","methodology_zh":"干物质烧失量"},{"_id":"6a837a57af14b9c0e7b1fdab","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 05 04, 19 08 05, 20 02 01","methodology":"Straty przy prażeniu suchej masy","parameters":[{"name":"Zakres","range":"(0,5 – 80,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Straty przy prażeniu suchej masy\nZakres (0,5 – 80,0) %\nMetoda wagowa","reference":"PN-EN 15169:2011+Ap1:2012","norm_bases":["PN-EN 15169:2011+Ap1:2012"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 05 04, 19 08 05, 20 02 01 Straty przy prażeniu suchej masy\nZakres (0,5 – 80,0) %\nMetoda wagowa PN-EN 15169:2011+Ap1:2012 Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 05 04, 19 08 05, 20 02 01 Straty przy prazeniu suchej masy\nZakres (0,5 – 80,0) %\nMetoda wagowa PN-EN 15169:2011+Ap1:2012","categories":["environment"],"row_index":94,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Loss on ignition of dry matter","parameters_en":[{"name":"Range","range":"(0,5 – 80,0) %"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Loss on ignition of dry matter Gravimetric method waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Range PN-EN 15169:2011+Ap1:2012","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(0,5 – 80,0) %"}],"search_zh":"干物质烧失量 重量法 依据气候部长关于废物目录的条例的废物代码。 范围 PN-EN 15169:2011+Ap1:2012","technique_zh":"重量法","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。","methodology_zh":"干物质烧失量"},{"_id":"6a837a57af14b9c0e7b1fdac","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 05 04, 20 02 01","methodology":"Zawartość tlenków i pierwiastków:","parameters":[{"name":"SiO2","range":"(0,10 – 95,0) %"},{"name":"Si","range":"(0,05 – 44,4) %"},{"name":"Al2O3","range":"(0,017 – 40,0) %"},{"name":"Al","range":"(0,008 – 21,2) %"},{"name":"Fe2O3","range":"(0,10 – 99,0) %"},{"name":"Fe","range":"(0,06 – 69,2) %"},{"name":"CaO","range":"(0,02 – 70,0) %"},{"name":"Ca","range":"(0,014 – 50,0) %"},{"name":"MgO","range":"(0,03 – 30,0) %"},{"name":"Mg","range":"(0,018 – 18,1) %"},{"name":"Na2O","range":"(0,01 – 10,0) %"},{"name":"Na","range":"(0,007 – 7,42) %"},{"name":"K2O","range":"(0,01 – 10,0) %"},{"name":"K","range":"(0,008 – 8,3) %"},{"name":"P2O5","range":"(0,022 – 22,94) %"},{"name":"PO4","range":"(0,03 – 30,7) %"},{"name":"P","range":"(0,01 – 10,0) %"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość tlenków i pierwiastków:\nZakres:\nSiO2 (0,10 – 95,0) %\nSi (0,05 – 44,4) %\nAl2O3 (0,017 – 40,0) %\nAl (0,008 – 21,2) %\nFe2O3 (0,10 – 99,0) %\nFe (0,06 – 69,2) %\nCaO (0,02 – 70,0) %\nCa (0,014 – 50,0) %\nMgO (0,03 – 30,0) %\nMg (0,018 – 18,1) %\nNa2O (0,01 – 10,0) %\nNa (0,007 – 7,42) %\nK2O (0,01 – 10,0) %\nK (0,008 – 8,3) %\nP2O5 (0,022 – 22,94) %\nPO4 (0,03 – 30,7) %\nP (0,01 – 10,0) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN 13657:2006 | PN-EN 13656:2021-05 | PN-EN ISO 11885:2009","norm_bases":["PN-EN 13657:2006","PN-EN 13656:2021-05","PN-EN ISO 11885:2009"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 05 04, 20 02 01 Zawartość tlenków i pierwiastków:\nZakres:\nSiO2 (0,10 – 95,0) %\nSi (0,05 – 44,4) %\nAl2O3 (0,017 – 40,0) %\nAl (0,008 – 21,2) %\nFe2O3 (0,10 – 99,0) %\nFe (0,06 – 69,2) %\nCaO (0,02 – 70,0) %\nCa (0,014 – 50,0) %\nMgO (0,03 – 30,0) %\nMg (0,018 – 18,1) %\nNa2O (0,01 – 10,0) %\nNa (0,007 – 7,42) %\nK2O (0,01 – 10,0) %\nK (0,008 – 8,3) %\nP2O5 (0,022 – 22,94) %\nPO4 (0,03 – 30,7) %\nP (0,01 – 10,0) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN 13657:2006 | PN-EN 13656:2021-05 | PN-EN ISO 11885:2009 Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 05 04, 20 02 01 Zawartosc tlenkow i pierwiastkow:\nZakres:\nSiO2 (0,10 – 95,0) %\nSi (0,05 – 44,4) %\nAl2O3 (0,017 – 40,0) %\nAl (0,008 – 21,2) %\nFe2O3 (0,10 – 99,0) %\nFe (0,06 – 69,2) %\nCaO (0,02 – 70,0) %\nCa (0,014 – 50,0) %\nMgO (0,03 – 30,0) %\nMg (0,018 – 18,1) %\nNa2O (0,01 – 10,0) %\nNa (0,007 – 7,42) %\nK2O (0,01 – 10,0) %\nK (0,008 – 8,3) %\nP2O5 (0,022 – 22,94) %\nPO4 (0,03 – 30,7) %\nP (0,01 – 10,0) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN 13657:2006 | PN-EN 13656:2021-05 | PN-EN ISO 11885:2009","categories":["environment"],"row_index":95,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of oxides and elements:","parameters_en":[{"name":"SiO2","range":"(0,10 – 95,0) %"},{"name":"Si","range":"(0,05 – 44,4) %"},{"name":"Al2O3","range":"(0,017 – 40,0) %"},{"name":"Al","range":"(0,008 – 21,2) %"},{"name":"Fe2O3","range":"(0,10 – 99,0) %"},{"name":"Fe","range":"(0,06 – 69,2) %"},{"name":"CaO","range":"(0,02 – 70,0) %"},{"name":"Ca","range":"(0,014 – 50,0) %"},{"name":"MgO","range":"(0,03 – 30,0) %"},{"name":"Mg","range":"(0,018 – 18,1) %"},{"name":"Na2O","range":"(0,01 – 10,0) %"},{"name":"Na","range":"(0,007 – 7,42) %"},{"name":"K2O","range":"(0,01 – 10,0) %"},{"name":"K","range":"(0,008 – 8,3) %"},{"name":"P2O5","range":"(0,022 – 22,94) %"},{"name":"PO4","range":"(0,03 – 30,7) %"},{"name":"P","range":"(0,01 – 10,0) %"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Content of oxides and elements: Inductively coupled plasma optical emission spectrometry (ICP-OES) waste codes according to the Regulation of the Minister of Climate on the waste catalogue. SiO2 Si Al2O3 Al Fe2O3 Fe CaO Ca MgO Mg Na2O Na K2O K P2O5 PO4 P PN-EN 13657:2006 | PN-EN 13656:2021-05 | PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","search_zh":"电感耦合等离子体原子发射光谱法（ICP-OES） 依据气候部长关于废物目录的条例的废物代码。 SiO2 Si Al2O3 Al Fe2O3 Fe CaO Ca MgO Mg Na2O Na K2O K P2O5 P PN-EN 13657:2006 | PN-EN 13656:2021-05 | PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","parameters_zh":[{"name":"SiO2","range":"(0,10 – 95,0) %"},{"name":"Si","range":"(0,05 – 44,4) %"},{"name":"Al2O3","range":"(0,017 – 40,0) %"},{"name":"Al","range":"(0,008 – 21,2) %"},{"name":"Fe2O3","range":"(0,10 – 99,0) %"},{"name":"Fe","range":"(0,06 – 69,2) %"},{"name":"CaO","range":"(0,02 – 70,0) %"},{"name":"Ca","range":"(0,014 – 50,0) %"},{"name":"MgO","range":"(0,03 – 30,0) %"},{"name":"Mg","range":"(0,018 – 18,1) %"},{"name":"Na2O","range":"(0,01 – 10,0) %"},{"name":"Na","range":"(0,007 – 7,42) %"},{"name":"K2O","range":"(0,01 – 10,0) %"},{"name":"K","range":"(0,008 – 8,3) %"},{"name":"P2O5","range":"(0,022 – 22,94) %"},{"name":"PO4","range":"(0,03 – 30,7) %"},{"name":"P","range":"(0,01 – 10,0) %"}],"regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。"},{"_id":"6a837a57af14b9c0e7b1fdad","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 21, 10 01 24, 10 01 25, 10 01 26, 10 01 80, 10 01 82, 19 09 02, 19 09 03, 19 09 04, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania – lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Produkt odsiarczania, Popiół z torfu i drewna","methodology":"Zawartość tlenków i pierwiastków:","parameters":[{"name":"SiO2","range":"(0,1 – 95,0) %"},{"name":"Si","range":"(0,05 – 44,4) %"},{"name":"Al.2O3","range":"(0,017 – 40,0) %"},{"name":"Al","range":"(0,008 – 21,2) %"},{"name":"Fe2O3","range":"(0,1 – 99,0) %"},{"name":"Fe","range":"(0,06 – 69,2) %"},{"name":"CaO","range":"(0,02 – 70,0) %"},{"name":"Ca","range":"(0,014 – 50,0) %"},{"name":"MgO","range":"(0,03 – 30,0) %"},{"name":"Mg","range":"(0,018 – 18,1) %"},{"name":"Na2O","range":"(0,01 – 10,0) %"},{"name":"Na","range":"(0,007 – 7,42) %"},{"name":"K2O","range":"(0,01 – 10,0) %"},{"name":"K","range":"(0,008 – 8,3) %"},{"name":"P","range":"(0,01 – 10,0) %"},{"name":"P2O5","range":"(0,02 – 22,9) %"},{"name":"B","range":"(14,0 – 5300) mg/kg"},{"name":"Ba","range":"(10,0 – 14300) mg/kg"},{"name":"Cd","range":"(7,0 – 30,0) mg/kg"},{"name":"Co","range":"(8,0 – 100) mg/kg"},{"name":"Cr","range":"(10,0 – 300) mg/kg"},{"name":"Cu","range":"(10,0 – 5000) mg/kg"},{"name":"Mo","range":"(8,0 – 100) mg/kg"},{"name":"Mn","range":"(6,0 – 3500) mg/kg"},{"name":"Ni","range":"(8,0 – 1500) mg/kg"},{"name":"Pb","range":"(5,0 – 1500) mg/kg"},{"name":"Sr","range":"(19,0 – 1000) mg/kg"},{"name":"V","range":"(7,0 – 4000) mg/kg"},{"name":"Zn","range":"(5,0 – 5500) mg/kg"},{"name":"As","range":"(10,0 – 1000) mg/kg"},{"name":"Sn","range":"(2,0 – 1000) mg/kg"},{"name":"Ti","range":"(0,01 – 10,0) %"},{"name":"TiO2","range":"(0,017 – 16,7) %"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość tlenków i pierwiastków:\nZakres:\nSiO2 (0,1 – 95,0) %\nSi (0,05 – 44,4) %\nAl.2O3 (0,017 – 40,0) %\nAl (0,008 – 21,2) %\nFe2O3 (0,1 – 99,0) %\nFe (0,06 – 69,2) %\nCaO (0,02 – 70,0) %\nCa (0,014 – 50,0) %\nMgO (0,03 – 30,0) %\nMg (0,018 – 18,1) %\nNa2O (0,01 – 10,0) %\nNa (0,007 – 7,42) %\nK2O (0,01 – 10,0) %\nK (0,008 – 8,3) %\nP (0,01 – 10,0) %\nP2O5 (0,02 – 22,9) %\nB (14,0 – 5300) mg/kg\nBa (10,0 – 14300) mg/kg\nCd (7,0 – 30,0) mg/kg\nCo (8,0 – 100) mg/kg\nCr (10,0 – 300) mg/kg\nCu (10,0 – 5000) mg/kg\nMo (8,0 – 100) mg/kg\nMn (6,0 – 3500) mg/kg\nNi (8,0 – 1500) mg/kg\nPb (5,0 – 1500) mg/kg\nSr (19,0 – 1000) mg/kg\nV (7,0 – 4000) mg/kg\nZn (5,0 – 5500) mg/kg\nAs (10,0 – 1000) mg/kg\nSn (2,0 – 1000) mg/kg\nTi (0,01 – 10,0) %\nTiO2 (0,017 – 16,7) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN 13657:2006 | PN-EN 13656:2021-05 | PN-EN 196-2:2013-11 pkt. 4.5.2 | PN-EN ISO 11885:2009","norm_bases":["PN-EN 13657:2006","PN-EN 13656:2021-05","PN-EN 196-2:2013-11 pkt. 4.5.2","PN-EN ISO 11885:2009"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 21, 10 01 24, 10 01 25, 10 01 26, 10 01 80, 10 01 82, 19 09 02, 19 09 03, 19 09 04, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania – lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Produkt odsiarczania, Popiół z torfu i drewna Zawartość tlenków i pierwiastków:\nZakres:\nSiO2 (0,1 – 95,0) %\nSi (0,05 – 44,4) %\nAl.2O3 (0,017 – 40,0) %\nAl (0,008 – 21,2) %\nFe2O3 (0,1 – 99,0) %\nFe (0,06 – 69,2) %\nCaO (0,02 – 70,0) %\nCa (0,014 – 50,0) %\nMgO (0,03 – 30,0) %\nMg (0,018 – 18,1) %\nNa2O (0,01 – 10,0) %\nNa (0,007 – 7,42) %\nK2O (0,01 – 10,0) %\nK (0,008 – 8,3) %\nP (0,01 – 10,0) %\nP2O5 (0,02 – 22,9) %\nB (14,0 – 5300) mg/kg\nBa (10,0 – 14300) mg/kg\nCd (7,0 – 30,0) mg/kg\nCo (8,0 – 100) mg/kg\nCr (10,0 – 300) mg/kg\nCu (10,0 – 5000) mg/kg\nMo (8,0 – 100) mg/kg\nMn (6,0 – 3500) mg/kg\nNi (8,0 – 1500) mg/kg\nPb (5,0 – 1500) mg/kg\nSr (19,0 – 1000) mg/kg\nV (7,0 – 4000) mg/kg\nZn (5,0 – 5500) mg/kg\nAs (10,0 – 1000) mg/kg\nSn (2,0 – 1000) mg/kg\nTi (0,01 – 10,0) %\nTiO2 (0,017 – 16,7) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN 13657:2006 | PN-EN 13656:2021-05 | PN-EN 196-2:2013-11 pkt. 4.5.2 | PN-EN ISO 11885:2009 Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 21, 10 01 24, 10 01 25, 10 01 26, 10 01 80, 10 01 82, 19 09 02, 19 09 03, 19 09 04, Popiol, zuzel, Mieszanka popiolowo zuzlowa, Popiol z produktami odsiarczania – lotny, Popiol z produktami odsiarczania - fluidalny, Piaski ze zloz fluidalnych, Produkt odsiarczania, Popiol z torfu i drewna Zawartosc tlenkow i pierwiastkow:\nZakres:\nSiO2 (0,1 – 95,0) %\nSi (0,05 – 44,4) %\nAl.2O3 (0,017 – 40,0) %\nAl (0,008 – 21,2) %\nFe2O3 (0,1 – 99,0) %\nFe (0,06 – 69,2) %\nCaO (0,02 – 70,0) %\nCa (0,014 – 50,0) %\nMgO (0,03 – 30,0) %\nMg (0,018 – 18,1) %\nNa2O (0,01 – 10,0) %\nNa (0,007 – 7,42) %\nK2O (0,01 – 10,0) %\nK (0,008 – 8,3) %\nP (0,01 – 10,0) %\nP2O5 (0,02 – 22,9) %\nB (14,0 – 5300) mg/kg\nBa (10,0 – 14300) mg/kg\nCd (7,0 – 30,0) mg/kg\nCo (8,0 – 100) mg/kg\nCr (10,0 – 300) mg/kg\nCu (10,0 – 5000) mg/kg\nMo (8,0 – 100) mg/kg\nMn (6,0 – 3500) mg/kg\nNi (8,0 – 1500) mg/kg\nPb (5,0 – 1500) mg/kg\nSr (19,0 – 1000) mg/kg\nV (7,0 – 4000) mg/kg\nZn (5,0 – 5500) mg/kg\nAs (10,0 – 1000) mg/kg\nSn (2,0 – 1000) mg/kg\nTi (0,01 – 10,0) %\nTiO2 (0,017 – 16,7) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN 13657:2006 | PN-EN 13656:2021-05 | PN-EN 196-2:2013-11 pkt. 4.5.2 | PN-EN ISO 11885:2009","categories":["environment"],"row_index":96,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of oxides and elements:","parameters_en":[{"name":"SiO2","range":"(0,1 – 95,0) %"},{"name":"Si","range":"(0,05 – 44,4) %"},{"name":"Al.2O3","range":"(0,017 – 40,0) %"},{"name":"Al","range":"(0,008 – 21,2) %"},{"name":"Fe2O3","range":"(0,1 – 99,0) %"},{"name":"Fe","range":"(0,06 – 69,2) %"},{"name":"CaO","range":"(0,02 – 70,0) %"},{"name":"Ca","range":"(0,014 – 50,0) %"},{"name":"MgO","range":"(0,03 – 30,0) %"},{"name":"Mg","range":"(0,018 – 18,1) %"},{"name":"Na2O","range":"(0,01 – 10,0) %"},{"name":"Na","range":"(0,007 – 7,42) %"},{"name":"K2O","range":"(0,01 – 10,0) %"},{"name":"K","range":"(0,008 – 8,3) %"},{"name":"P","range":"(0,01 – 10,0) %"},{"name":"P2O5","range":"(0,02 – 22,9) %"},{"name":"B","range":"(14,0 – 5300) mg/kg"},{"name":"Ba","range":"(10,0 – 14300) mg/kg"},{"name":"Cd","range":"(7,0 – 30,0) mg/kg"},{"name":"Co","range":"(8,0 – 100) mg/kg"},{"name":"Cr","range":"(10,0 – 300) mg/kg"},{"name":"Cu","range":"(10,0 – 5000) mg/kg"},{"name":"Mo","range":"(8,0 – 100) mg/kg"},{"name":"Mn","range":"(6,0 – 3500) mg/kg"},{"name":"Ni","range":"(8,0 – 1500) mg/kg"},{"name":"Pb","range":"(5,0 – 1500) mg/kg"},{"name":"Sr","range":"(19,0 – 1000) mg/kg"},{"name":"V","range":"(7,0 – 4000) mg/kg"},{"name":"Zn","range":"(5,0 – 5500) mg/kg"},{"name":"As","range":"(10,0 – 1000) mg/kg"},{"name":"Sn","range":"(2,0 – 1000) mg/kg"},{"name":"Ti","range":"(0,01 – 10,0) %"},{"name":"TiO2","range":"(0,017 – 16,7) %"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Content of oxides and elements: Inductively coupled plasma optical emission spectrometry (ICP-OES) waste codes according to the Regulation of the Minister of Climate on the waste catalogue. SiO2 Si Al.2O3 Al Fe2O3 Fe CaO Ca MgO Mg Na2O Na K2O K P P2O5 B Ba Cd Co Cr Cu Mo Mn Ni Pb Sr V Zn As Sn Ti TiO2 PN-EN 13657:2006 | PN-EN 13656:2021-05 | PN-EN 196-2:2013-11 pkt. 4.5.2 | PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","parameters_zh":[{"name":"SiO2","range":"(0,1 – 95,0) %"},{"name":"Si","range":"(0,05 – 44,4) %"},{"name":"Al.2O3","range":"(0,017 – 40,0) %"},{"name":"Al","range":"(0,008 – 21,2) %"},{"name":"Fe2O3","range":"(0,1 – 99,0) %"},{"name":"Fe","range":"(0,06 – 69,2) %"},{"name":"CaO","range":"(0,02 – 70,0) %"},{"name":"Ca","range":"(0,014 – 50,0) %"},{"name":"MgO","range":"(0,03 – 30,0) %"},{"name":"Mg","range":"(0,018 – 18,1) %"},{"name":"Na2O","range":"(0,01 – 10,0) %"},{"name":"Na","range":"(0,007 – 7,42) %"},{"name":"K2O","range":"(0,01 – 10,0) %"},{"name":"K","range":"(0,008 – 8,3) %"},{"name":"P","range":"(0,01 – 10,0) %"},{"name":"P2O5","range":"(0,02 – 22,9) %"},{"name":"B","range":"(14,0 – 5300) mg/kg"},{"name":"Ba","range":"(10,0 – 14300) mg/kg"},{"name":"Cd","range":"(7,0 – 30,0) mg/kg"},{"name":"Co","range":"(8,0 – 100) mg/kg"},{"name":"Cr","range":"(10,0 – 300) mg/kg"},{"name":"Cu","range":"(10,0 – 5000) mg/kg"},{"name":"Mo","range":"(8,0 – 100) mg/kg"},{"name":"Mn","range":"(6,0 – 3500) mg/kg"},{"name":"Ni","range":"(8,0 – 1500) mg/kg"},{"name":"Pb","range":"(5,0 – 1500) mg/kg"},{"name":"Sr","range":"(19,0 – 1000) mg/kg"},{"name":"V","range":"(7,0 – 4000) mg/kg"},{"name":"Zn","range":"(5,0 – 5500) mg/kg"},{"name":"As","range":"(10,0 – 1000) mg/kg"},{"name":"Sn","range":"(2,0 – 1000) mg/kg"},{"name":"Ti","range":"(0,01 – 10,0) %"},{"name":"TiO2","range":"(0,017 – 16,7) %"}],"search_zh":"电感耦合等离子体原子发射光谱法（ICP-OES） 依据气候部长关于废物目录的条例的废物代码。 SiO2 Si Al Fe2O3 Fe CaO Ca MgO Mg Na2O Na K2O K P P2O5 B Ba Cd Co Cr Cu Mo Mn Ni Pb Sr V Zn As Sn Ti TiO2 PN-EN 13657:2006 | PN-EN 13656:2021-05 | PN-EN 196-2:2013-11 pkt. 4.5.2 | PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。"},{"_id":"6a837a57af14b9c0e7b1fdae","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Odpadyo) kod: 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 21, 10 01 24, 10 01 25, 10 01 82, 17 09 04, 19 08 05, 19 09 03, 20 02 01, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania – lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych","methodology":"Zawartość wilgoci przemijającej","parameters":[{"name":"Zakres","range":"(0,01 – 62,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci przemijającej\nZakres (0,01 – 62,0) %\nMetoda wagowa","reference":"PN-80/G-04511","norm_bases":["PN-80/G-04511"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpadyo) kod: 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 21, 10 01 24, 10 01 25, 10 01 82, 17 09 04, 19 08 05, 19 09 03, 20 02 01, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania – lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych Zawartość wilgoci przemijającej\nZakres (0,01 – 62,0) %\nMetoda wagowa PN-80/G-04511 Odpadyo) kod: 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 21, 10 01 24, 10 01 25, 10 01 82, 17 09 04, 19 08 05, 19 09 03, 20 02 01, Popiol, zuzel, Mieszanka popiolowo zuzlowa, Popiol z produktami odsiarczania – lotny, Popiol z produktami odsiarczania - fluidalny, Piaski ze zloz fluidalnych Zawartosc wilgoci przemijajacej\nZakres (0,01 – 62,0) %\nMetoda wagowa PN-80/G-04511","categories":["environment"],"row_index":97,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free moisture content","parameters_en":[{"name":"Range","range":"(0,01 – 62,0) %"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Free moisture content Gravimetric method waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Range PN-80/G-04511","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(0,01 – 62,0) %"}],"search_zh":"外在水分含量 重量法 依据气候部长关于废物目录的条例的废物代码。 范围 PN-80/G-04511","technique_zh":"重量法","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。","methodology_zh":"外在水分含量"},{"_id":"6a837a57af14b9c0e7b1fdaf","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Odpadyo) kod: 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 21, 10 01 24, 10 01 25, 10 01 82, 17 09 04, 19 08 05, 19 09 03, 20 02 01, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania – lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych","methodology":"Zawartość wilgoci całkowitej","parameters":[{"name":"Zakres","range":"(0,05 – 63,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci całkowitej\nZakres (0,05 – 63,0) %\nMetoda wagowa","reference":"PN-80/G-04511","norm_bases":["PN-80/G-04511"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpadyo) kod: 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 21, 10 01 24, 10 01 25, 10 01 82, 17 09 04, 19 08 05, 19 09 03, 20 02 01, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania – lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych Zawartość wilgoci całkowitej\nZakres (0,05 – 63,0) %\nMetoda wagowa PN-80/G-04511 Odpadyo) kod: 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 21, 10 01 24, 10 01 25, 10 01 82, 17 09 04, 19 08 05, 19 09 03, 20 02 01, Popiol, zuzel, Mieszanka popiolowo zuzlowa, Popiol z produktami odsiarczania – lotny, Popiol z produktami odsiarczania - fluidalny, Piaski ze zloz fluidalnych Zawartosc wilgoci calkowitej\nZakres (0,05 – 63,0) %\nMetoda wagowa PN-80/G-04511","categories":["environment"],"row_index":98,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total moisture content","parameters_en":[{"name":"Range","range":"(0,05 – 63,0) %"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Total moisture content Gravimetric method waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Range PN-80/G-04511","technique_en":"Gravimetric method","methodology_zh":"全水分含量","parameters_zh":[{"name":"范围","range":"(0,05 – 63,0) %"}],"search_zh":"全水分含量 重量法 依据气候部长关于废物目录的条例的废物代码。 范围 PN-80/G-04511","technique_zh":"重量法","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。"},{"_id":"6a837a57af14b9c0e7b1fdb0","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Odpadyo) kod: 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 21, 10 01 24, 10 01 25, 10 01 82, 17 09 04, 19 08 05, 19 09 03, 20 02 01, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania – lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych","methodology":"Zawartość wilgoci w próbce analitycznej","parameters":[{"name":"Zakres","range":"(0,01 – 16,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (0,01 – 16,0) %\nMetoda wagowa","reference":"PN-80/G-04511","norm_bases":["PN-80/G-04511"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpadyo) kod: 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 21, 10 01 24, 10 01 25, 10 01 82, 17 09 04, 19 08 05, 19 09 03, 20 02 01, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania – lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych Zawartość wilgoci w próbce analitycznej\nZakres (0,01 – 16,0) %\nMetoda wagowa PN-80/G-04511 Odpadyo) kod: 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 21, 10 01 24, 10 01 25, 10 01 82, 17 09 04, 19 08 05, 19 09 03, 20 02 01, Popiol, zuzel, Mieszanka popiolowo zuzlowa, Popiol z produktami odsiarczania – lotny, Popiol z produktami odsiarczania - fluidalny, Piaski ze zloz fluidalnych Zawartosc wilgoci w probce analitycznej\nZakres (0,01 – 16,0) %\nMetoda wagowa PN-80/G-04511","categories":["environment"],"row_index":99,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Moisture content in the analytical sample","parameters_en":[{"name":"Range","range":"(0,01 – 16,0) %"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Moisture content in the analytical sample Gravimetric method waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Range PN-80/G-04511","technique_en":"Gravimetric method","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(0,01 – 16,0) %"}],"search_zh":"分析样品水分含量 重量法 依据气候部长关于废物目录的条例的废物代码。 范围 PN-80/G-04511","technique_zh":"重量法","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。"},{"_id":"6a837a57af14b9c0e7b1fdb1","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Odpadyo) kod: 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 21, 10 01 24, 10 01 25, 10 01 82, 17 09 04, 19 08 05, 19 09 03, 20 02 01, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania – lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych","methodology":"Zawartość wilgoci w próbce analitycznej","parameters":[{"name":"Zakres","range":"(0,01 – 16,00) %"}],"technique":"Metoda termograwimetryczna TGA","techniques":["Metoda termograwimetryczna TGA"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (0,01 – 16,00) %\nMetoda termograwimetryczna TGA","reference":"PN-G-04560:1998","norm_bases":["PN-G-04560:1998"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpadyo) kod: 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 21, 10 01 24, 10 01 25, 10 01 82, 17 09 04, 19 08 05, 19 09 03, 20 02 01, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania – lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych Zawartość wilgoci w próbce analitycznej\nZakres (0,01 – 16,00) %\nMetoda termograwimetryczna TGA PN-G-04560:1998 Odpadyo) kod: 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 21, 10 01 24, 10 01 25, 10 01 82, 17 09 04, 19 08 05, 19 09 03, 20 02 01, Popiol, zuzel, Mieszanka popiolowo zuzlowa, Popiol z produktami odsiarczania – lotny, Popiol z produktami odsiarczania - fluidalny, Piaski ze zloz fluidalnych Zawartosc wilgoci w probce analitycznej\nZakres (0,01 – 16,00) %\nMetoda termograwimetryczna TGA PN-G-04560:1998","categories":["environment"],"row_index":100,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Moisture content in the analytical sample","parameters_en":[{"name":"Range","range":"(0,01 – 16,00) %"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Moisture content in the analytical sample Thermogravimetric method TGA waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Range PN-G-04560:1998","technique_en":"Thermogravimetric method TGA","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(0,01 – 16,00) %"}],"search_zh":"分析样品水分含量 依据气候部长关于废物目录的条例的废物代码。 范围 PN-G-04560:1998","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。"},{"_id":"6a837a57af14b9c0e7b1fdb2","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Odpadyo) kod: 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 21, 10 01 24, 10 01 25, 10 01 82, 17 09 04, 19 08 05, 19 09 03, 20 02 01, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania – lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych","methodology":"Zawartość popiołu","parameters":[{"name":"Zakres","range":"(0,20 – 100,00) %"}],"technique":"Metoda termograwimetryczna TGA","techniques":["Metoda termograwimetryczna TGA"],"computed":[],"activity":"Zawartość popiołu\nZakres (0,20 – 100,00) %\nMetoda termograwimetryczna TGA","reference":"PN-G-04560:1998","norm_bases":["PN-G-04560:1998"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpadyo) kod: 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 21, 10 01 24, 10 01 25, 10 01 82, 17 09 04, 19 08 05, 19 09 03, 20 02 01, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania – lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych Zawartość popiołu\nZakres (0,20 – 100,00) %\nMetoda termograwimetryczna TGA PN-G-04560:1998 Odpadyo) kod: 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 21, 10 01 24, 10 01 25, 10 01 82, 17 09 04, 19 08 05, 19 09 03, 20 02 01, Popiol, zuzel, Mieszanka popiolowo zuzlowa, Popiol z produktami odsiarczania – lotny, Popiol z produktami odsiarczania - fluidalny, Piaski ze zloz fluidalnych Zawartosc popiolu\nZakres (0,20 – 100,00) %\nMetoda termograwimetryczna TGA PN-G-04560:1998","categories":["environment"],"row_index":101,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ash content","parameters_en":[{"name":"Range","range":"(0,20 – 100,00) %"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Ash content Thermogravimetric method TGA waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Range PN-G-04560:1998","technique_en":"Thermogravimetric method TGA","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(0,20 – 100,00) %"}],"search_zh":"灰分含量 依据气候部长关于废物目录的条例的废物代码。 范围 PN-G-04560:1998","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。"},{"_id":"6a837a57af14b9c0e7b1fdb3","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Odpadyo) kod: 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 21, 10 01 24, 10 01 25, 10 01 82, 17 09 04, 19 08 05, 19 09 03, 20 02 01, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania – lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych","methodology":"Zawartość popiołu","parameters":[{"name":"Zakres","range":"(0,20 – 100,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość popiołu\nZakres (0,20 – 100,0) %\nMetoda wagowa","reference":"PN-ISO 1171:2002","norm_bases":["PN-ISO 1171:2002"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpadyo) kod: 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 21, 10 01 24, 10 01 25, 10 01 82, 17 09 04, 19 08 05, 19 09 03, 20 02 01, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania – lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych Zawartość popiołu\nZakres (0,20 – 100,0) %\nMetoda wagowa PN-ISO 1171:2002 Odpadyo) kod: 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 21, 10 01 24, 10 01 25, 10 01 82, 17 09 04, 19 08 05, 19 09 03, 20 02 01, Popiol, zuzel, Mieszanka popiolowo zuzlowa, Popiol z produktami odsiarczania – lotny, Popiol z produktami odsiarczania - fluidalny, Piaski ze zloz fluidalnych Zawartosc popiolu\nZakres (0,20 – 100,0) %\nMetoda wagowa PN-ISO 1171:2002","categories":["environment"],"row_index":102,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ash content","parameters_en":[{"name":"Range","range":"(0,20 – 100,0) %"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Ash content Gravimetric method waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Range PN-ISO 1171:2002","technique_en":"Gravimetric method","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(0,20 – 100,0) %"}],"search_zh":"灰分含量 重量法 依据气候部长关于废物目录的条例的废物代码。 范围 PN-ISO 1171:2002","technique_zh":"重量法","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。"},{"_id":"6a837a57af14b9c0e7b1fdb4","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Odpadyo) kod: 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 21, 10 01 24, 10 01 25, 10 01 82, 17 09 04, 19 08 05, 19 09 03, 20 02 01, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania – lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych","methodology":"Zawartość siarki całkowitej","parameters":[{"name":"Zakres","range":"(0,015 – 12,50) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość siarki całkowitej\nZakres (0,015 – 12,50) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04584:2001","norm_bases":["PN-G-04584:2001"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpadyo) kod: 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 21, 10 01 24, 10 01 25, 10 01 82, 17 09 04, 19 08 05, 19 09 03, 20 02 01, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania – lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych Zawartość siarki całkowitej\nZakres (0,015 – 12,50) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04584:2001 Odpadyo) kod: 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 21, 10 01 24, 10 01 25, 10 01 82, 17 09 04, 19 08 05, 19 09 03, 20 02 01, Popiol, zuzel, Mieszanka popiolowo zuzlowa, Popiol z produktami odsiarczania – lotny, Popiol z produktami odsiarczania - fluidalny, Piaski ze zloz fluidalnych Zawartosc siarki calkowitej\nZakres (0,015 – 12,50) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04584:2001","categories":["environment"],"row_index":103,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total sulfur content","parameters_en":[{"name":"Range","range":"(0,015 – 12,50) %"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Total sulfur content High-temperature combustion with IR detection waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Range PN-G-04584:2001","technique_en":"High-temperature combustion with IR detection","methodology_zh":"全硫含量","parameters_zh":[{"name":"范围","range":"(0,015 – 12,50) %"}],"search_zh":"全硫含量 高温燃烧红外检测法 依据气候部长关于废物目录的条例的废物代码。 范围 PN-G-04584:2001","technique_zh":"高温燃烧红外检测法","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。"},{"_id":"6a837a57af14b9c0e7b1fdb5","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Odpadyo) kod: 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 21, 10 01 24, 10 01 25, 10 01 82, 17 09 04, 19 08 05, 19 09 03, 20 02 01, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania – lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych","methodology":"Ciepło spalania","parameters":[{"name":"Zakres","range":"(250 – 25500) kJ/kg"},{"name":"Wartość opałowa (z obliczeń)"}],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna"],"computed":[],"activity":"Ciepło spalania\nZakres:\nZakres (250 – 25500) kJ/kg\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna","reference":"PN-81/G-04513","norm_bases":["PN-81/G-04513"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpadyo) kod: 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 21, 10 01 24, 10 01 25, 10 01 82, 17 09 04, 19 08 05, 19 09 03, 20 02 01, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania – lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych Ciepło spalania\nZakres:\nZakres (250 – 25500) kJ/kg\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna PN-81/G-04513 Odpadyo) kod: 01 04 12, 01 04 81, 10 01 01, 10 01 02, 10 01 21, 10 01 24, 10 01 25, 10 01 82, 17 09 04, 19 08 05, 19 09 03, 20 02 01, Popiol, zuzel, Mieszanka popiolowo zuzlowa, Popiol z produktami odsiarczania – lotny, Popiol z produktami odsiarczania - fluidalny, Piaski ze zloz fluidalnych Cieplo spalania\nZakres:\nZakres (250 – 25500) kJ/kg\nWartosc opalowa (z obliczen)\nMetoda kalorymetryczna PN-81/G-04513","categories":["environment"],"row_index":104,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gross calorific value","parameters_en":[{"name":"Range","range":"(250 – 25500) kJ/kg"},{"name":"Net calorific value (calculated)"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Gross calorific value Calorimetric method waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Range Net calorific value (calculated) PN-81/G-04513","technique_en":"Calorimetric method","methodology_zh":"高位发热量","parameters_zh":[{"name":"范围","range":"(250 – 25500) kJ/kg"},{"name":"低位发热量（计算值）"}],"search_zh":"高位发热量 量热法 依据气候部长关于废物目录的条例的废物代码。 范围 低位发热量（计算值） PN-81/G-04513","technique_zh":"量热法","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。"},{"_id":"6a837a57af14b9c0e7b1fdb6","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Materiał budowlany: kruszywa","methodology":"Zawartość tlenków i pierwiastków:","parameters":[{"name":"SiO2","range":"(0,10 – 95,0) %"},{"name":"Si","range":"(0,05 – 44,4) %"},{"name":"Al2O3","range":"(0,017 – 40,0) %"},{"name":"Al","range":"(0,008 – 21,2) %"},{"name":"Fe2O3","range":"(0,014 – 99,0) %"},{"name":"Fe","range":"(0,009 – 69,2) %"},{"name":"CaO","range":"(0,02 – 70,0) %"},{"name":"Ca","range":"(0,014 – 50,0) %"},{"name":"MgO","range":"(0,03 – 30,0) %"},{"name":"Mg","range":"(0,018 – 18,1) %"},{"name":"Na2O","range":"(0,01 – 10,0) %"},{"name":"Na","range":"(0,007 – 7,42) %"},{"name":"K2O","range":"(0,01 – 10,0) %"},{"name":"K","range":"(0,008 – 8,3) %"},{"name":"P","range":"(0,01 – 10,0) %"},{"name":"P2O5","range":"(0,02 – 22,9) %"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość tlenków i pierwiastków:\nZakres:\nSiO2 (0,10 – 95,0) %\nSi (0,05 – 44,4) %\nAl2O3 (0,017 – 40,0) %\nAl (0,008 – 21,2) %\nFe2O3 (0,014 – 99,0) %\nFe (0,009 – 69,2) %\nCaO (0,02 – 70,0) %\nCa (0,014 – 50,0) %\nMgO (0,03 – 30,0) %\nMg (0,018 – 18,1) %\nNa2O (0,01 – 10,0) %\nNa (0,007 – 7,42) %\nK2O (0,01 – 10,0) %\nK (0,008 – 8,3) %\nP (0,01 – 10,0) %\nP2O5 (0,02 – 22,9) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN 13657:2006 | PN-EN 13656:2021-05 | PN-EN ISO 11885:2009","norm_bases":["PN-EN 13657:2006","PN-EN 13656:2021-05","PN-EN ISO 11885:2009"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiał budowlany: kruszywa Zawartość tlenków i pierwiastków:\nZakres:\nSiO2 (0,10 – 95,0) %\nSi (0,05 – 44,4) %\nAl2O3 (0,017 – 40,0) %\nAl (0,008 – 21,2) %\nFe2O3 (0,014 – 99,0) %\nFe (0,009 – 69,2) %\nCaO (0,02 – 70,0) %\nCa (0,014 – 50,0) %\nMgO (0,03 – 30,0) %\nMg (0,018 – 18,1) %\nNa2O (0,01 – 10,0) %\nNa (0,007 – 7,42) %\nK2O (0,01 – 10,0) %\nK (0,008 – 8,3) %\nP (0,01 – 10,0) %\nP2O5 (0,02 – 22,9) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN 13657:2006 | PN-EN 13656:2021-05 | PN-EN ISO 11885:2009 Material budowlany: kruszywa Zawartosc tlenkow i pierwiastkow:\nZakres:\nSiO2 (0,10 – 95,0) %\nSi (0,05 – 44,4) %\nAl2O3 (0,017 – 40,0) %\nAl (0,008 – 21,2) %\nFe2O3 (0,014 – 99,0) %\nFe (0,009 – 69,2) %\nCaO (0,02 – 70,0) %\nCa (0,014 – 50,0) %\nMgO (0,03 – 30,0) %\nMg (0,018 – 18,1) %\nNa2O (0,01 – 10,0) %\nNa (0,007 – 7,42) %\nK2O (0,01 – 10,0) %\nK (0,008 – 8,3) %\nP (0,01 – 10,0) %\nP2O5 (0,02 – 22,9) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN 13657:2006 | PN-EN 13656:2021-05 | PN-EN ISO 11885:2009","categories":["materials","construction"],"row_index":105,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of oxides and elements:","parameters_en":[{"name":"SiO2","range":"(0,10 – 95,0) %"},{"name":"Si","range":"(0,05 – 44,4) %"},{"name":"Al2O3","range":"(0,017 – 40,0) %"},{"name":"Al","range":"(0,008 – 21,2) %"},{"name":"Fe2O3","range":"(0,014 – 99,0) %"},{"name":"Fe","range":"(0,009 – 69,2) %"},{"name":"CaO","range":"(0,02 – 70,0) %"},{"name":"Ca","range":"(0,014 – 50,0) %"},{"name":"MgO","range":"(0,03 – 30,0) %"},{"name":"Mg","range":"(0,018 – 18,1) %"},{"name":"Na2O","range":"(0,01 – 10,0) %"},{"name":"Na","range":"(0,007 – 7,42) %"},{"name":"K2O","range":"(0,01 – 10,0) %"},{"name":"K","range":"(0,008 – 8,3) %"},{"name":"P","range":"(0,01 – 10,0) %"},{"name":"P2O5","range":"(0,02 – 22,9) %"}],"search_en":"Construction material: aggregates Content of oxides and elements: Inductively coupled plasma optical emission spectrometry (ICP-OES) SiO2 Si Al2O3 Al Fe2O3 Fe CaO Ca MgO Mg Na2O Na K2O K P P2O5 PN-EN 13657:2006 | PN-EN 13656:2021-05 | PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Construction material: aggregates","search_zh":"建筑材料：集料 电感耦合等离子体原子发射光谱法（ICP-OES） SiO2 Si Al2O3 Al Fe2O3 Fe CaO Ca MgO Mg Na2O Na K2O K P P2O5 PN-EN 13657:2006 | PN-EN 13656:2021-05 | PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","parameters_zh":[{"name":"SiO2","range":"(0,10 – 95,0) %"},{"name":"Si","range":"(0,05 – 44,4) %"},{"name":"Al2O3","range":"(0,017 – 40,0) %"},{"name":"Al","range":"(0,008 – 21,2) %"},{"name":"Fe2O3","range":"(0,014 – 99,0) %"},{"name":"Fe","range":"(0,009 – 69,2) %"},{"name":"CaO","range":"(0,02 – 70,0) %"},{"name":"Ca","range":"(0,014 – 50,0) %"},{"name":"MgO","range":"(0,03 – 30,0) %"},{"name":"Mg","range":"(0,018 – 18,1) %"},{"name":"Na2O","range":"(0,01 – 10,0) %"},{"name":"Na","range":"(0,007 – 7,42) %"},{"name":"K2O","range":"(0,01 – 10,0) %"},{"name":"K","range":"(0,008 – 8,3) %"},{"name":"P","range":"(0,01 – 10,0) %"},{"name":"P2O5","range":"(0,02 – 22,9) %"}],"test_object_zh":"建筑材料：集料"},{"_id":"6a837a57af14b9c0e7b1fdb7","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Materiał budowlany: kruszywa","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(2,5 - 1200) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie chlorków\nZakres (2,5 - 1200) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-93/G-11010 | PN-EN ISO 10304-1:2009+AC:2012 | PN-EN 12457-4:2006 | PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-93/G-11010","PN-EN ISO 10304-1:2009+AC:2012","PN-EN 12457-4:2006","PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiał budowlany: kruszywa Stężenie chlorków\nZakres (2,5 - 1200) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-93/G-11010 | PN-EN ISO 10304-1:2009+AC:2012 | PN-EN 12457-4:2006 | PN-EN ISO 10304-1:2009+AC:2012 Material budowlany: kruszywa Stezenie chlorkow\nZakres (2,5 - 1200) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-93/G-11010 | PN-EN ISO 10304-1:2009+AC:2012 | PN-EN 12457-4:2006 | PN-EN ISO 10304-1:2009+AC:2012","categories":["materials","construction"],"row_index":106,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(2,5 - 1200) mg/l"}],"search_en":"Construction material: aggregates Chloride concentration Ion chromatography with conductometric detection (IC-CD) Range PN-93/G-11010 | PN-EN ISO 10304-1:2009+AC:2012 | PN-EN 12457-4:2006 | PN-EN ISO 10304-1:2009+AC:2012","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Construction material: aggregates","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(2,5 - 1200) mg/l"}],"search_zh":"建筑材料：集料 氯化物浓度 离子色谱-电导检测法（IC-CD） 范围 PN-93/G-11010 | PN-EN ISO 10304-1:2009+AC:2012 | PN-EN 12457-4:2006 | PN-EN ISO 10304-1:2009+AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"建筑材料：集料"},{"_id":"6a837a57af14b9c0e7b1fdb8","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Materiał budowlany: kruszywa","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(2,5– - 2000) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie siarczanów\nZakres (2,5– - 2000) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-93/G-11010 | PN-EN ISO 10304-1:2009+AC:2012 | PN-EN 12457-4:2006 | PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-93/G-11010","PN-EN ISO 10304-1:2009+AC:2012","PN-EN 12457-4:2006","PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiał budowlany: kruszywa Stężenie siarczanów\nZakres (2,5– - 2000) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-93/G-11010 | PN-EN ISO 10304-1:2009+AC:2012 | PN-EN 12457-4:2006 | PN-EN ISO 10304-1:2009+AC:2012 Material budowlany: kruszywa Stezenie siarczanow\nZakres (2,5– - 2000) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-93/G-11010 | PN-EN ISO 10304-1:2009+AC:2012 | PN-EN 12457-4:2006 | PN-EN ISO 10304-1:2009+AC:2012","categories":["materials","construction"],"row_index":107,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Range","range":"(2,5– - 2000) mg/l"}],"search_en":"Construction material: aggregates Sulfate concentration Ion chromatography with conductometric detection (IC-CD) Range PN-93/G-11010 | PN-EN ISO 10304-1:2009+AC:2012 | PN-EN 12457-4:2006 | PN-EN ISO 10304-1:2009+AC:2012","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Construction material: aggregates","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(2,5– - 2000) mg/l"}],"search_zh":"建筑材料：集料 硫酸盐浓度 离子色谱-电导检测法（IC-CD） 范围 PN-93/G-11010 | PN-EN ISO 10304-1:2009+AC:2012 | PN-EN 12457-4:2006 | PN-EN ISO 10304-1:2009+AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"建筑材料：集料"},{"_id":"6a837a57af14b9c0e7b1fdb9","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Materiał budowlany: kruszywa","methodology":"Stężenie fluorków","parameters":[{"name":"Zakres","range":"(0,20 – 6,20) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie fluorków\nZakres (0,20 – 6,20) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN 12457-4:2006 | PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN 12457-4:2006","PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiał budowlany: kruszywa Stężenie fluorków\nZakres (0,20 – 6,20) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN 12457-4:2006 | PN-EN ISO 10304-1:2009+AC:2012 Material budowlany: kruszywa Stezenie fluorkow\nZakres (0,20 – 6,20) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN 12457-4:2006 | PN-EN ISO 10304-1:2009+AC:2012","categories":["materials","construction"],"row_index":108,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fluoride concentration","parameters_en":[{"name":"Range","range":"(0,20 – 6,20) mg/l"}],"search_en":"Construction material: aggregates Fluoride concentration Ion chromatography with conductometric detection (IC-CD) Range PN-EN 12457-4:2006 | PN-EN ISO 10304-1:2009+AC:2012","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Construction material: aggregates","parameters_zh":[{"name":"范围","range":"(0,20 – 6,20) mg/l"}],"search_zh":"建筑材料：集料 氟化物浓度 离子色谱-电导检测法（IC-CD） 范围 PN-EN 12457-4:2006 | PN-EN ISO 10304-1:2009+AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","methodology_zh":"氟化物浓度","test_object_zh":"建筑材料：集料"},{"_id":"6a837a57af14b9c0e7b1fdba","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Materiał budowlany: kruszywa","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-93/G-11010 | PN-EN ISO 10523:2012 | PN-EN 12457-4:2006 | PN-EN ISO 10523:2012","norm_bases":["PN-93/G-11010","PN-EN ISO 10523:2012","PN-EN 12457-4:2006","PN-EN ISO 10523:2012"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiał budowlany: kruszywa pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-93/G-11010 | PN-EN ISO 10523:2012 | PN-EN 12457-4:2006 | PN-EN ISO 10523:2012 Material budowlany: kruszywa pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-93/G-11010 | PN-EN ISO 10523:2012 | PN-EN 12457-4:2006 | PN-EN ISO 10523:2012","categories":["materials","construction"],"row_index":109,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"search_en":"Construction material: aggregates pH Potentiometric method Range PN-93/G-11010 | PN-EN ISO 10523:2012 | PN-EN 12457-4:2006 | PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Construction material: aggregates","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"建筑材料：集料 pH 值 电位法 范围 PN-93/G-11010 | PN-EN ISO 10523:2012 | PN-EN 12457-4:2006 | PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"建筑材料：集料"},{"_id":"6a837a57af14b9c0e7b1fdbb","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Materiał budowlany: kruszywa","methodology":"Chemiczne zapotrzebowanie tlenu ChZT-Cr","parameters":[{"name":"Zakres","range":"(10,0 – 70,0) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu ChZT-Cr\nZakres (10,0 – 70,0) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-93/G-11010 | PN-ISO 15705:2005","norm_bases":["PN-93/G-11010","PN-ISO 15705:2005"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiał budowlany: kruszywa Chemiczne zapotrzebowanie tlenu ChZT-Cr\nZakres (10,0 – 70,0) mg/l O2\nMetoda spektrofotometryczna PN-93/G-11010 | PN-ISO 15705:2005 Material budowlany: kruszywa Chemiczne zapotrzebowanie tlenu ChZT-Cr\nZakres (10,0 – 70,0) mg/l O2\nMetoda spektrofotometryczna PN-93/G-11010 | PN-ISO 15705:2005","categories":["materials","construction"],"row_index":110,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand COD-Cr","parameters_en":[{"name":"Range","range":"(10,0 – 70,0) mg/l O2"}],"search_en":"Construction material: aggregates Chemical oxygen demand COD-Cr Spectrophotometric method Range PN-93/G-11010 | PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Construction material: aggregates","parameters_zh":[{"name":"范围","range":"(10,0 – 70,0) mg/l O2"}],"search_zh":"建筑材料：集料 化学需氧量 COD-Cr 分光光度法 范围 PN-93/G-11010 | PN-ISO 15705:2005","technique_zh":"分光光度法","methodology_zh":"化学需氧量 COD-Cr","test_object_zh":"建筑材料：集料"},{"_id":"6a837a57af14b9c0e7b1fdbc","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Materiał budowlany: kruszywa","methodology":"Stężenie metali, Na - (1,0 – 100,0) mg/l, K - (0,70 – 50,0) mg/l, Zn - (0,007 – 1,00) mg/l, Cd - (0,007 – 0,20) mg/l, Cu - (0,014 – 0,50) mg/l, Cr - (0,015 – 0,50) mg/l, Pb - (0,020 – 0,50) mg/l, Ni - (0,008 – 0,50) mg/l","parameters":[],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie metali, Na - (1,0 – 100,0) mg/l, K - (0,70 – 50,0) mg/l, Zn - (0,007 – 1,00) mg/l, Cd - (0,007 – 0,20) mg/l, Cu - (0,014 – 0,50) mg/l, Cr - (0,015 – 0,50) mg/l, Pb - (0,020 – 0,50) mg/l, Ni - (0,008 – 0,50) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-93/G-11010 | PN-EN ISO 11885:2009","norm_bases":["PN-93/G-11010","PN-EN ISO 11885:2009"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiał budowlany: kruszywa Stężenie metali, Na - (1,0 – 100,0) mg/l, K - (0,70 – 50,0) mg/l, Zn - (0,007 – 1,00) mg/l, Cd - (0,007 – 0,20) mg/l, Cu - (0,014 – 0,50) mg/l, Cr - (0,015 – 0,50) mg/l, Pb - (0,020 – 0,50) mg/l, Ni - (0,008 – 0,50) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-93/G-11010 | PN-EN ISO 11885:2009 Material budowlany: kruszywa Stezenie metali, Na - (1,0 – 100,0) mg/l, K - (0,70 – 50,0) mg/l, Zn - (0,007 – 1,00) mg/l, Cd - (0,007 – 0,20) mg/l, Cu - (0,014 – 0,50) mg/l, Cr - (0,015 – 0,50) mg/l, Pb - (0,020 – 0,50) mg/l, Ni - (0,008 – 0,50) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-93/G-11010 | PN-EN ISO 11885:2009","categories":["materials","construction"],"row_index":111,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Metal concentrations, Na - (1,0 – 100,0) mg/l, K - (0,70 – 50,0) mg/l, Zn - (0,007 – 1,00) mg/l, Cd - (0,007 – 0,20) mg/l, Cu - (0,014 – 0,50) mg/l, Cr - (0,015 – 0,50) mg/l, Pb - (0,020 – 0,50) mg/l, Ni - (0,008 – 0,50) mg/l","search_en":"Construction material: aggregates Metal concentrations, Na - (1,0 – 100,0) mg/l, K - (0,70 – 50,0) mg/l, Zn - (0,007 – 1,00) mg/l, Cd - (0,007 – 0,20) mg/l, Cu - (0,014 – 0,50) mg/l, Cr - (0,015 – 0,50) mg/l, Pb - (0,020 – 0,50) mg/l, Ni - (0,008 – 0,50) mg/l Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-93/G-11010 | PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Construction material: aggregates","search_zh":"建筑材料：集料 电感耦合等离子体原子发射光谱法（ICP-OES） PN-93/G-11010 | PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"建筑材料：集料"},{"_id":"6a837a57af14b9c0e7b1fdbd","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Materiał budowlany: kruszywa","methodology":"Stężenie pierwiastków, As - (0,008 – 0,50) mg/l, Ba - (0,010 – 0,50) mg/l, Zn - (0,007 – 1,00) mg/l, Cd - (0,007 – 0,50) mg/l, Cu - (0,014 – 0,50) mg/l, Cr - (0,015 – 0,50) mg/l, Pb - (0,020 – 0,50) mg/l, Ni - (0,008 – 0,50) mg/l, Sb - (0,016 – 0,50) mg/l, Se - (0,006 – 0,50) mg/l, Mo - (0,008 – 0,50) mg/l","parameters":[],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie pierwiastków, As - (0,008 – 0,50) mg/l, Ba - (0,010 – 0,50) mg/l, Zn - (0,007 – 1,00) mg/l, Cd - (0,007 – 0,50) mg/l, Cu - (0,014 – 0,50) mg/l, Cr - (0,015 – 0,50) mg/l, Pb - (0,020 – 0,50) mg/l, Ni - (0,008 – 0,50) mg/l, Sb - (0,016 – 0,50) mg/l, Se - (0,006 – 0,50) mg/l, Mo - (0,008 – 0,50) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN 12457-4:2006 | PN-EN ISO 11885:2009","norm_bases":["PN-EN 12457-4:2006","PN-EN ISO 11885:2009"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiał budowlany: kruszywa Stężenie pierwiastków, As - (0,008 – 0,50) mg/l, Ba - (0,010 – 0,50) mg/l, Zn - (0,007 – 1,00) mg/l, Cd - (0,007 – 0,50) mg/l, Cu - (0,014 – 0,50) mg/l, Cr - (0,015 – 0,50) mg/l, Pb - (0,020 – 0,50) mg/l, Ni - (0,008 – 0,50) mg/l, Sb - (0,016 – 0,50) mg/l, Se - (0,006 – 0,50) mg/l, Mo - (0,008 – 0,50) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN 12457-4:2006 | PN-EN ISO 11885:2009 Material budowlany: kruszywa Stezenie pierwiastkow, As - (0,008 – 0,50) mg/l, Ba - (0,010 – 0,50) mg/l, Zn - (0,007 – 1,00) mg/l, Cd - (0,007 – 0,50) mg/l, Cu - (0,014 – 0,50) mg/l, Cr - (0,015 – 0,50) mg/l, Pb - (0,020 – 0,50) mg/l, Ni - (0,008 – 0,50) mg/l, Sb - (0,016 – 0,50) mg/l, Se - (0,006 – 0,50) mg/l, Mo - (0,008 – 0,50) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN 12457-4:2006 | PN-EN ISO 11885:2009","categories":["materials","construction"],"row_index":112,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element concentrations, As - (0,008 – 0,50) mg/l, Ba - (0,010 – 0,50) mg/l, Zn - (0,007 – 1,00) mg/l, Cd - (0,007 – 0,50) mg/l, Cu - (0,014 – 0,50) mg/l, Cr - (0,015 – 0,50) mg/l, Pb - (0,020 – 0,50) mg/l, Ni - (0,008 – 0,50) mg/l, Sb - (0,016 – 0,50) mg/l, Se - (0,006 – 0,50) mg/l, Mo - (0,008 – 0,50) mg/l","search_en":"Construction material: aggregates Element concentrations, As - (0,008 – 0,50) mg/l, Ba - (0,010 – 0,50) mg/l, Zn - (0,007 – 1,00) mg/l, Cd - (0,007 – 0,50) mg/l, Cu - (0,014 – 0,50) mg/l, Cr - (0,015 – 0,50) mg/l, Pb - (0,020 – 0,50) mg/l, Ni - (0,008 – 0,50) mg/l, Sb - (0,016 – 0,50) mg/l, Se - (0,006 – 0,50) mg/l, Mo - (0,008 – 0,50) mg/l Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN 12457-4:2006 | PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Construction material: aggregates","search_zh":"建筑材料：集料 电感耦合等离子体原子发射光谱法（ICP-OES） PN-EN 12457-4:2006 | PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"建筑材料：集料"},{"_id":"6a837a57af14b9c0e7b1fdbe","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Materiał budowlany: kruszywa","methodology":"Stałe związki rozpuszczone","parameters":[{"name":"Zakres","range":"(10,0 – 3000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stałe związki rozpuszczone\nZakres (10,0 – 3000) mg/l\nMetoda wagowa","reference":"PN-EN 12457-4:2006 | PN-EN 15216:2022-03","norm_bases":["PN-EN 12457-4:2006","PN-EN 15216:2022-03"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiał budowlany: kruszywa Stałe związki rozpuszczone\nZakres (10,0 – 3000) mg/l\nMetoda wagowa PN-EN 12457-4:2006 | PN-EN 15216:2022-03 Material budowlany: kruszywa Stale zwiazki rozpuszczone\nZakres (10,0 – 3000) mg/l\nMetoda wagowa PN-EN 12457-4:2006 | PN-EN 15216:2022-03","categories":["materials","construction"],"row_index":113,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissolved solids","parameters_en":[{"name":"Range","range":"(10,0 – 3000) mg/l"}],"search_en":"Construction material: aggregates Dissolved solids Gravimetric method Range PN-EN 12457-4:2006 | PN-EN 15216:2022-03","technique_en":"Gravimetric method","test_object_en":"Construction material: aggregates","parameters_zh":[{"name":"范围","range":"(10,0 – 3000) mg/l"}],"search_zh":"建筑材料：集料 重量法 范围 PN-EN 12457-4:2006 | PN-EN 15216:2022-03","technique_zh":"重量法","test_object_zh":"建筑材料：集料"},{"_id":"6a837a57af14b9c0e7b1fdbf","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Odpadyo) kod: 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 21, 10 01 24, 10 01 25, 10 01 26, 10 01 80, 10 01 82, 17 06 04, 17 09 04, 19 09 02, 19 09 03, 19 09 04, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania – lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Produkt odsiarczania, Popiół z torfu i drewna","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 – 13,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 – 13,0\nMetoda potencjometryczna","reference":"PN-EN 12457-4:2006 | PN-EN ISO 10523:2012 | PN-93/G-11010 | PN-EN ISO 10523:2012","norm_bases":["PN-EN 12457-4:2006","PN-EN ISO 10523:2012","PN-93/G-11010","PN-EN ISO 10523:2012"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpadyo) kod: 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 21, 10 01 24, 10 01 25, 10 01 26, 10 01 80, 10 01 82, 17 06 04, 17 09 04, 19 09 02, 19 09 03, 19 09 04, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania – lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Produkt odsiarczania, Popiół z torfu i drewna pH\nZakres 4,0 – 13,0\nMetoda potencjometryczna PN-EN 12457-4:2006 | PN-EN ISO 10523:2012 | PN-93/G-11010 | PN-EN ISO 10523:2012 Odpadyo) kod: 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 21, 10 01 24, 10 01 25, 10 01 26, 10 01 80, 10 01 82, 17 06 04, 17 09 04, 19 09 02, 19 09 03, 19 09 04, Popiol, zuzel, Mieszanka popiolowo zuzlowa, Popiol z produktami odsiarczania – lotny, Popiol z produktami odsiarczania - fluidalny, Piaski ze zloz fluidalnych, Produkt odsiarczania, Popiol z torfu i drewna pH\nZakres 4,0 – 13,0\nMetoda potencjometryczna PN-EN 12457-4:2006 | PN-EN ISO 10523:2012 | PN-93/G-11010 | PN-EN ISO 10523:2012","categories":["environment"],"row_index":114,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 – 13,0"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"pH Potentiometric method waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Range PN-EN 12457-4:2006 | PN-EN ISO 10523:2012 | PN-93/G-11010 | PN-EN ISO 10523:2012","technique_en":"Potentiometric method","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 13,0"}],"search_zh":"pH 值 电位法 依据气候部长关于废物目录的条例的废物代码。 范围 PN-EN 12457-4:2006 | PN-EN ISO 10523:2012 | PN-93/G-11010 | PN-EN ISO 10523:2012","technique_zh":"电位法","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。"},{"_id":"6a837a57af14b9c0e7b1fdc0","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Odpadyo) kod: 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 21, 10 01 24, 10 01 25, 10 01 26, 10 01 80, 10 01 82, 17 06 04, 17 09 04, 19 09 02, 19 09 03, 19 09 04, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania – lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Produkt odsiarczania, Popiół z torfu i drewna","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(0,001– 200,0) mS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (0,001– 200,0) mS/cm\nMetoda konduktometryczna","reference":"PN-EN 12457-4:2006 | PN-EN 27888:1999 | PN-93/G-11010 | PN-EN 27888:1999","norm_bases":["PN-EN 12457-4:2006","PN-EN 27888:1999","PN-93/G-11010","PN-EN 27888:1999"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpadyo) kod: 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 21, 10 01 24, 10 01 25, 10 01 26, 10 01 80, 10 01 82, 17 06 04, 17 09 04, 19 09 02, 19 09 03, 19 09 04, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania – lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Produkt odsiarczania, Popiół z torfu i drewna Przewodność elektryczna właściwa\nZakres (0,001– 200,0) mS/cm\nMetoda konduktometryczna PN-EN 12457-4:2006 | PN-EN 27888:1999 | PN-93/G-11010 | PN-EN 27888:1999 Odpadyo) kod: 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 21, 10 01 24, 10 01 25, 10 01 26, 10 01 80, 10 01 82, 17 06 04, 17 09 04, 19 09 02, 19 09 03, 19 09 04, Popiol, zuzel, Mieszanka popiolowo zuzlowa, Popiol z produktami odsiarczania – lotny, Popiol z produktami odsiarczania - fluidalny, Piaski ze zloz fluidalnych, Produkt odsiarczania, Popiol z torfu i drewna Przewodnosc elektryczna wlasciwa\nZakres (0,001– 200,0) mS/cm\nMetoda konduktometryczna PN-EN 12457-4:2006 | PN-EN 27888:1999 | PN-93/G-11010 | PN-EN 27888:1999","categories":["environment"],"row_index":115,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(0,001– 200,0) mS/cm"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Electrical conductivity Conductometric method waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Range PN-EN 12457-4:2006 | PN-EN 27888:1999 | PN-93/G-11010 | PN-EN 27888:1999","technique_en":"Conductometric method","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(0,001– 200,0) mS/cm"}],"search_zh":"电导率 电导法 依据气候部长关于废物目录的条例的废物代码。 范围 PN-EN 12457-4:2006 | PN-EN 27888:1999 | PN-93/G-11010 | PN-EN 27888:1999","technique_zh":"电导法","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。"},{"_id":"6a837a57af14b9c0e7b1fdc1","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 21, 10 01 24, 10 01 25, 10 01 26, 10 01 80, 10 01 82, 17 06 04, 17 09 04, 19 09 02, 19 09 03, 19 09 04, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Produkt odsiarczania, Popiół z torfu i drewna","methodology":"Całkowite substancje rozpuszczone (TDS)","parameters":[{"name":"Zakres","range":"(10,0 - 20000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Całkowite substancje rozpuszczone (TDS)\nZakres (10,0 - 20000) mg/l\nMetoda wagowa","reference":"PN-EN 12457-4:2006 | PN-EN 15216:2022-03","norm_bases":["PN-EN 12457-4:2006","PN-EN 15216:2022-03"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 21, 10 01 24, 10 01 25, 10 01 26, 10 01 80, 10 01 82, 17 06 04, 17 09 04, 19 09 02, 19 09 03, 19 09 04, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Produkt odsiarczania, Popiół z torfu i drewna Całkowite substancje rozpuszczone (TDS)\nZakres (10,0 - 20000) mg/l\nMetoda wagowa PN-EN 12457-4:2006 | PN-EN 15216:2022-03 Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 21, 10 01 24, 10 01 25, 10 01 26, 10 01 80, 10 01 82, 17 06 04, 17 09 04, 19 09 02, 19 09 03, 19 09 04, Popiol, zuzel, Mieszanka popiolowo zuzlowa, Popiol z produktami odsiarczania - lotny, Popiol z produktami odsiarczania - fluidalny, Piaski ze zloz fluidalnych, Produkt odsiarczania, Popiol z torfu i drewna Calkowite substancje rozpuszczone (TDS)\nZakres (10,0 - 20000) mg/l\nMetoda wagowa PN-EN 12457-4:2006 | PN-EN 15216:2022-03","categories":["environment"],"row_index":116,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total dissolved solids (TDS)","parameters_en":[{"name":"Range","range":"(10,0 - 20000) mg/l"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Total dissolved solids (TDS) Gravimetric method waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Range PN-EN 12457-4:2006 | PN-EN 15216:2022-03","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(10,0 - 20000) mg/l"}],"search_zh":"溶解性总固体（TDS） 重量法 依据气候部长关于废物目录的条例的废物代码。 范围 PN-EN 12457-4:2006 | PN-EN 15216:2022-03","technique_zh":"重量法","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。","methodology_zh":"溶解性总固体（TDS）"},{"_id":"6a837a57af14b9c0e7b1fdc2","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 21, 10 01 24, 10 01 25, 10 01 26, 10 01 80, 10 01 82, 17 06 04, 17 09 04, 19 09 02, 19 09 03, 19 09 04, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Produkt odsiarczania, Popiół z torfu i drewna","methodology":"Chemiczne zapotrzebowanie tlenu (ChZT-Cr)","parameters":[{"name":"Zakres","range":"(10 - 610) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu (ChZT-Cr)\nZakres (10 - 610) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-EN 12457-4:2006 | PN-93/G-11010 | PN-ISO 15705:2005","norm_bases":["PN-EN 12457-4:2006","PN-93/G-11010","PN-ISO 15705:2005"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 21, 10 01 24, 10 01 25, 10 01 26, 10 01 80, 10 01 82, 17 06 04, 17 09 04, 19 09 02, 19 09 03, 19 09 04, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Produkt odsiarczania, Popiół z torfu i drewna Chemiczne zapotrzebowanie tlenu (ChZT-Cr)\nZakres (10 - 610) mg/l O2\nMetoda spektrofotometryczna PN-EN 12457-4:2006 | PN-93/G-11010 | PN-ISO 15705:2005 Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 21, 10 01 24, 10 01 25, 10 01 26, 10 01 80, 10 01 82, 17 06 04, 17 09 04, 19 09 02, 19 09 03, 19 09 04, Popiol, zuzel, Mieszanka popiolowo zuzlowa, Popiol z produktami odsiarczania - lotny, Popiol z produktami odsiarczania - fluidalny, Piaski ze zloz fluidalnych, Produkt odsiarczania, Popiol z torfu i drewna Chemiczne zapotrzebowanie tlenu (ChZT-Cr)\nZakres (10 - 610) mg/l O2\nMetoda spektrofotometryczna PN-EN 12457-4:2006 | PN-93/G-11010 | PN-ISO 15705:2005","categories":["environment"],"row_index":117,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand (COD-Cr)","parameters_en":[{"name":"Range","range":"(10 - 610) mg/l O2"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Chemical oxygen demand (COD-Cr) Spectrophotometric method waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Range PN-EN 12457-4:2006 | PN-93/G-11010 | PN-ISO 15705:2005","technique_en":"Spectrophotometric method","methodology_zh":"化学需氧量（ChZT-Cr / CODCr）","parameters_zh":[{"name":"范围","range":"(10 - 610) mg/l O2"}],"search_zh":"化学需氧量（ChZT-Cr / CODCr） 分光光度法 依据气候部长关于废物目录的条例的废物代码。 范围 PN-EN 12457-4:2006 | PN-93/G-11010 | PN-ISO 15705:2005","technique_zh":"分光光度法","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。"},{"_id":"6a837a57af14b9c0e7b1fdc3","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 21, 10 01 24, 10 01 25, 10 01 26, 10 01 80, 10 01 82, 17 06 04, 17 09 04, 19 09 02, 19 09 03, 19 09 04, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Produkt odsiarczania, Popiół z torfu i drewna","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)","parameters":[{"name":"Zakres","range":"(5,0 – 16000) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (5,0 – 16000) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-EN 12457-4:2006 | PN-93/G-11010 | PN-ISO 6059:1999","norm_bases":["PN-EN 12457-4:2006","PN-93/G-11010","PN-ISO 6059:1999"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 21, 10 01 24, 10 01 25, 10 01 26, 10 01 80, 10 01 82, 17 06 04, 17 09 04, 19 09 02, 19 09 03, 19 09 04, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Produkt odsiarczania, Popiół z torfu i drewna Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (5,0 – 16000) mg/l CaCO3\nMetoda miareczkowa PN-EN 12457-4:2006 | PN-93/G-11010 | PN-ISO 6059:1999 Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 21, 10 01 24, 10 01 25, 10 01 26, 10 01 80, 10 01 82, 17 06 04, 17 09 04, 19 09 02, 19 09 03, 19 09 04, Popiol, zuzel, Mieszanka popiolowo zuzlowa, Popiol z produktami odsiarczania - lotny, Popiol z produktami odsiarczania - fluidalny, Piaski ze zloz fluidalnych, Produkt odsiarczania, Popiol z torfu i drewna Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna)\nZakres (5,0 – 16000) mg/l CaCO3\nMetoda miareczkowa PN-EN 12457-4:2006 | PN-93/G-11010 | PN-ISO 6059:1999","categories":["environment"],"row_index":118,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total content of calcium and magnesium (total hardness)","parameters_en":[{"name":"Range","range":"(5,0 – 16000) mg/l CaCO3"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Total content of calcium and magnesium (total hardness) Titrimetric method waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Range PN-EN 12457-4:2006 | PN-93/G-11010 | PN-ISO 6059:1999","technique_en":"Titrimetric method","methodology_zh":"钙与镁总量（总硬度）","parameters_zh":[{"name":"范围","range":"(5,0 – 16000) mg/l CaCO3"}],"search_zh":"钙与镁总量（总硬度） 滴定法 依据气候部长关于废物目录的条例的废物代码。 范围 PN-EN 12457-4:2006 | PN-93/G-11010 | PN-ISO 6059:1999","technique_zh":"滴定法","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。"},{"_id":"6a837a57af14b9c0e7b1fdc4","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 21, 10 01 24, 10 01 25, 10 01 26, 10 01 80, 10 01 82, 17 06 04, 17 09 04, 19 09 02, 19 09 03, 19 09 04, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Produkt odsiarczania, Popiół z torfu i drewna","methodology":"Zasadowość ogólna i zasadowość wobec fenoloftaleiny","parameters":[{"name":"Zakres","range":"(0,4 – 60) mmol/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zasadowość ogólna i zasadowość wobec fenoloftaleiny\nZakres (0,4 – 60) mmol/l\nMetoda miareczkowa","reference":"PN-EN 12457-4:2006 | PN-93/G-11010 | PN-EN ISO 9963-1:2001+Ap1:2004","norm_bases":["PN-EN 12457-4:2006","PN-93/G-11010","PN-EN ISO 9963-1:2001+Ap1:2004"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 21, 10 01 24, 10 01 25, 10 01 26, 10 01 80, 10 01 82, 17 06 04, 17 09 04, 19 09 02, 19 09 03, 19 09 04, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Produkt odsiarczania, Popiół z torfu i drewna Zasadowość ogólna i zasadowość wobec fenoloftaleiny\nZakres (0,4 – 60) mmol/l\nMetoda miareczkowa PN-EN 12457-4:2006 | PN-93/G-11010 | PN-EN ISO 9963-1:2001+Ap1:2004 Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 21, 10 01 24, 10 01 25, 10 01 26, 10 01 80, 10 01 82, 17 06 04, 17 09 04, 19 09 02, 19 09 03, 19 09 04, Popiol, zuzel, Mieszanka popiolowo zuzlowa, Popiol z produktami odsiarczania - lotny, Popiol z produktami odsiarczania - fluidalny, Piaski ze zloz fluidalnych, Produkt odsiarczania, Popiol z torfu i drewna Zasadowosc ogolna i zasadowosc wobec fenoloftaleiny\nZakres (0,4 – 60) mmol/l\nMetoda miareczkowa PN-EN 12457-4:2006 | PN-93/G-11010 | PN-EN ISO 9963-1:2001+Ap1:2004","categories":["environment"],"row_index":119,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total alkalinity and phenolphthalein alkalinity","parameters_en":[{"name":"Range","range":"(0,4 – 60) mmol/l"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Total alkalinity and phenolphthalein alkalinity Titrimetric method waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Range PN-EN 12457-4:2006 | PN-93/G-11010 | PN-EN ISO 9963-1:2001+Ap1:2004","technique_en":"Titrimetric method","parameters_zh":[{"name":"范围","range":"(0,4 – 60) mmol/l"}],"search_zh":"总碱度与酚酞碱度 滴定法 依据气候部长关于废物目录的条例的废物代码。 范围 PN-EN 12457-4:2006 | PN-93/G-11010 | PN-EN ISO 9963-1:2001+Ap1:2004","technique_zh":"滴定法","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。","methodology_zh":"总碱度与酚酞碱度"},{"_id":"6a837a57af14b9c0e7b1fdc5","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 21, 10 01 24, 10 01 25, 10 01 26, 10 01 80, 10 01 82, 17 06 04, 17 09 04, 19 09 02, 19 09 03, 19 09 04, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Produkt odsiarczania, Popiół z torfu i drewna","methodology":"Stężenie fosforanów","parameters":[{"name":"Zakres","range":"(0,01 – 3,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforanów\nZakres (0,01 – 3,00) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 12457-4:2006 | PN-93/G-11010 | PN-EN ISO 6878:2006 pkt. 4 +Ap1:2010+ Ap2:2010","norm_bases":["PN-EN 12457-4:2006","PN-93/G-11010","PN-EN ISO 6878:2006 pkt. 4 +Ap1:2010+ Ap2:2010"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 21, 10 01 24, 10 01 25, 10 01 26, 10 01 80, 10 01 82, 17 06 04, 17 09 04, 19 09 02, 19 09 03, 19 09 04, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Produkt odsiarczania, Popiół z torfu i drewna Stężenie fosforanów\nZakres (0,01 – 3,00) mg/l\nMetoda spektrofotometryczna PN-EN 12457-4:2006 | PN-93/G-11010 | PN-EN ISO 6878:2006 pkt. 4 +Ap1:2010+ Ap2:2010 Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 21, 10 01 24, 10 01 25, 10 01 26, 10 01 80, 10 01 82, 17 06 04, 17 09 04, 19 09 02, 19 09 03, 19 09 04, Popiol, zuzel, Mieszanka popiolowo zuzlowa, Popiol z produktami odsiarczania - lotny, Popiol z produktami odsiarczania - fluidalny, Piaski ze zloz fluidalnych, Produkt odsiarczania, Popiol z torfu i drewna Stezenie fosforanow\nZakres (0,01 – 3,00) mg/l\nMetoda spektrofotometryczna PN-EN 12457-4:2006 | PN-93/G-11010 | PN-EN ISO 6878:2006 pkt. 4 +Ap1:2010+ Ap2:2010","categories":["environment"],"row_index":120,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phosphate concentration","parameters_en":[{"name":"Range","range":"(0,01 – 3,00) mg/l"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Phosphate concentration Spectrophotometric method waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Range PN-EN 12457-4:2006 | PN-93/G-11010 | PN-EN ISO 6878:2006 pkt. 4 +Ap1:2010+ Ap2:2010","technique_en":"Spectrophotometric method","parameters_zh":[{"name":"范围","range":"(0,01 – 3,00) mg/l"}],"search_zh":"磷酸盐浓度 分光光度法 依据气候部长关于废物目录的条例的废物代码。 范围 PN-EN 12457-4:2006 | PN-93/G-11010 | PN-EN ISO 6878:2006 pkt. 4 +Ap1:2010+ Ap2:2010","technique_zh":"分光光度法","methodology_zh":"磷酸盐浓度","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。"},{"_id":"6a837a57af14b9c0e7b1fdc6","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 21, 10 01 24, 10 01 25, 10 01 26, 10 01 80, 10 01 82, 17 06 04, 17 09 04, 19 09 02, 19 09 03, 19 09 04, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Produkt odsiarczania, Popiół z torfu i drewna","methodology":"Stężenie chromu +6","parameters":[{"name":"Zakres","range":"(0,010 – 0,700) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chromu +6\nZakres (0,010 – 0,700) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 12457-4:2006 | PN-93/G-11010 | IB-DPA-47 wersja 07 z dnia 02-01-2026 r. | na podstawie testu kuwetowego HACH 8023","norm_bases":["PN-EN 12457-4:2006","PN-93/G-11010","IB-DPA-47 wersja 07 z dnia 02-01-2026 r.","na podstawie testu kuwetowego HACH 8023"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 21, 10 01 24, 10 01 25, 10 01 26, 10 01 80, 10 01 82, 17 06 04, 17 09 04, 19 09 02, 19 09 03, 19 09 04, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Produkt odsiarczania, Popiół z torfu i drewna Stężenie chromu +6\nZakres (0,010 – 0,700) mg/l\nMetoda spektrofotometryczna PN-EN 12457-4:2006 | PN-93/G-11010 | IB-DPA-47 wersja 07 z dnia 02-01-2026 r. | na podstawie testu kuwetowego HACH 8023 Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 21, 10 01 24, 10 01 25, 10 01 26, 10 01 80, 10 01 82, 17 06 04, 17 09 04, 19 09 02, 19 09 03, 19 09 04, Popiol, zuzel, Mieszanka popiolowo zuzlowa, Popiol z produktami odsiarczania - lotny, Popiol z produktami odsiarczania - fluidalny, Piaski ze zloz fluidalnych, Produkt odsiarczania, Popiol z torfu i drewna Stezenie chromu +6\nZakres (0,010 – 0,700) mg/l\nMetoda spektrofotometryczna PN-EN 12457-4:2006 | PN-93/G-11010 | IB-DPA-47 wersja 07 z dnia 02-01-2026 r. | na podstawie testu kuwetowego HACH 8023","categories":["environment"],"row_index":121,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chromium +6 concentration","parameters_en":[{"name":"Range","range":"(0,010 – 0,700) mg/l"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Chromium +6 concentration Spectrophotometric method waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Range PN-EN 12457-4:2006 | PN-93/G-11010 | IB-DPA-47 wersja 07 z dnia 02-01-2026 r. | na podstawie testu kuwetowego HACH 8023","technique_en":"Spectrophotometric method","parameters_zh":[{"name":"范围","range":"(0,010 – 0,700) mg/l"}],"search_zh":"六价铬浓度 分光光度法 依据气候部长关于废物目录的条例的废物代码。 范围 PN-EN 12457-4:2006 | PN-93/G-11010 | IB-DPA-47 wersja 07 z dnia 02-01-2026 r. | na podstawie testu kuwetowego HACH 8023","technique_zh":"分光光度法","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。","methodology_zh":"六价铬浓度"},{"_id":"6a837a57af14b9c0e7b1fdc7","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 21, 10 01 24, 10 01 25, 10 01 26, 10 01 80, 10 01 82, 17 06 04, 17 09 04, 19 09 02, 19 09 03, 19 09 04, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Produkt odsiarczania, Popiół z torfu i drewna","methodology":"Stężenie anionów","parameters":[{"name":"Chlorki","range":"(0,05 - 18000) mg/l"},{"name":"Siarczany","range":"(0,05 - 6000) mg/l"},{"name":"Fosforany","range":"(0,1 – 70,0) mg/l"},{"name":"Fluorki","range":"(0,01 – 27,0) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie anionów\nZakres:\nChlorki (0,05 - 18000) mg/l\nSiarczany (0,05 - 6000) mg/l\nFosforany (0,1 – 70,0) mg/l\nFluorki (0,01 – 27,0) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN 12457-4:2006 | PN-93/G-11010 | PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN 12457-4:2006","PN-93/G-11010","PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 21, 10 01 24, 10 01 25, 10 01 26, 10 01 80, 10 01 82, 17 06 04, 17 09 04, 19 09 02, 19 09 03, 19 09 04, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Produkt odsiarczania, Popiół z torfu i drewna Stężenie anionów\nZakres:\nChlorki (0,05 - 18000) mg/l\nSiarczany (0,05 - 6000) mg/l\nFosforany (0,1 – 70,0) mg/l\nFluorki (0,01 – 27,0) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN 12457-4:2006 | PN-93/G-11010 | PN-EN ISO 10304-1:2009+AC:2012 Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 21, 10 01 24, 10 01 25, 10 01 26, 10 01 80, 10 01 82, 17 06 04, 17 09 04, 19 09 02, 19 09 03, 19 09 04, Popiol, zuzel, Mieszanka popiolowo zuzlowa, Popiol z produktami odsiarczania - lotny, Popiol z produktami odsiarczania - fluidalny, Piaski ze zloz fluidalnych, Produkt odsiarczania, Popiol z torfu i drewna Stezenie anionow\nZakres:\nChlorki (0,05 - 18000) mg/l\nSiarczany (0,05 - 6000) mg/l\nFosforany (0,1 – 70,0) mg/l\nFluorki (0,01 – 27,0) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN 12457-4:2006 | PN-93/G-11010 | PN-EN ISO 10304-1:2009+AC:2012","categories":["environment"],"row_index":122,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Anion concentrations","parameters_en":[{"name":"Chlorides","range":"(0,05 - 18000) mg/l"},{"name":"Sulfates","range":"(0,05 - 6000) mg/l"},{"name":"Phosphates","range":"(0,1 – 70,0) mg/l"},{"name":"Fluorides","range":"(0,01 – 27,0) mg/l"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Anion concentrations Ion chromatography with conductometric detection (IC-CD) waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Chlorides Sulfates Phosphates Fluorides PN-EN 12457-4:2006 | PN-93/G-11010 | PN-EN ISO 10304-1:2009+AC:2012","technique_en":"Ion chromatography with conductometric detection (IC-CD)","methodology_zh":"阴离子浓度","parameters_zh":[{"name":"氯化物","range":"(0,05 - 18000) mg/l"},{"name":"硫酸盐","range":"(0,05 - 6000) mg/l"},{"name":"磷酸盐","range":"(0,1 – 70,0) mg/l"},{"name":"氟化物","range":"(0,01 – 27,0) mg/l"}],"search_zh":"阴离子浓度 离子色谱-电导检测法（IC-CD） 依据气候部长关于废物目录的条例的废物代码。 氯化物 硫酸盐 磷酸盐 氟化物 PN-EN 12457-4:2006 | PN-93/G-11010 | PN-EN ISO 10304-1:2009+AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。"},{"_id":"6a837a57af14b9c0e7b1fdc8","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 21, 10 01 24, 10 01 25, 10 01 26, 10 01 80, 10 01 82, 17 06 04, 17 09 04, 19 09 02, 19 09 03, 19 09 04, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Produkt odsiarczania, Popiół z torfu i drewna","methodology":"Stężenie pierwiastków","parameters":[{"name":"As","range":"(0,008 – 2,0) mg/l"},{"name":"Sb","range":"(0,016 – 2,0) mg/l"},{"name":"Se","range":"(0,006 – 2,0) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie pierwiastków\nZakres:\nAs (0,008 – 2,0) mg/l\nSb (0,016 – 2,0) mg/l\nSe (0,006 – 2,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN 12457-4:2006 | PN-93/G-11010 | PN-EN ISO 11885:2009","norm_bases":["PN-EN 12457-4:2006","PN-93/G-11010","PN-EN ISO 11885:2009"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 21, 10 01 24, 10 01 25, 10 01 26, 10 01 80, 10 01 82, 17 06 04, 17 09 04, 19 09 02, 19 09 03, 19 09 04, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Produkt odsiarczania, Popiół z torfu i drewna Stężenie pierwiastków\nZakres:\nAs (0,008 – 2,0) mg/l\nSb (0,016 – 2,0) mg/l\nSe (0,006 – 2,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN 12457-4:2006 | PN-93/G-11010 | PN-EN ISO 11885:2009 Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 21, 10 01 24, 10 01 25, 10 01 26, 10 01 80, 10 01 82, 17 06 04, 17 09 04, 19 09 02, 19 09 03, 19 09 04, Popiol, zuzel, Mieszanka popiolowo zuzlowa, Popiol z produktami odsiarczania - lotny, Popiol z produktami odsiarczania - fluidalny, Piaski ze zloz fluidalnych, Produkt odsiarczania, Popiol z torfu i drewna Stezenie pierwiastkow\nZakres:\nAs (0,008 – 2,0) mg/l\nSb (0,016 – 2,0) mg/l\nSe (0,006 – 2,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN 12457-4:2006 | PN-93/G-11010 | PN-EN ISO 11885:2009","categories":["environment"],"row_index":123,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element concentration","parameters_en":[{"name":"As","range":"(0,008 – 2,0) mg/l"},{"name":"Sb","range":"(0,016 – 2,0) mg/l"},{"name":"Se","range":"(0,006 – 2,0) mg/l"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Element concentration Inductively coupled plasma optical emission spectrometry (ICP-OES) waste codes according to the Regulation of the Minister of Climate on the waste catalogue. As Sb Se PN-EN 12457-4:2006 | PN-93/G-11010 | PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","methodology_zh":"元素浓度","search_zh":"元素浓度 电感耦合等离子体原子发射光谱法（ICP-OES） 依据气候部长关于废物目录的条例的废物代码。 As Sb Se PN-EN 12457-4:2006 | PN-93/G-11010 | PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","parameters_zh":[{"name":"As","range":"(0,008 – 2,0) mg/l"},{"name":"Sb","range":"(0,016 – 2,0) mg/l"},{"name":"Se","range":"(0,006 – 2,0) mg/l"}],"regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。"},{"_id":"6a837a57af14b9c0e7b1fdc9","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 21, 10 01 24, 10 01 25, 10 01 26, 10 01 80, 10 01 82, 17 06 04, 17 09 04, 19 09 02, 19 09 03, 19 09 04, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Produkt odsiarczania, Popiół z torfu i drewna","methodology":"Stężenie pierwiastków","parameters":[{"name":"B","range":"(0,014 – 100) mg/l"},{"name":"Ba","range":"(0,010 – 10,0) mg/l"},{"name":"Ca","range":"(5,0 – 4600) mg/l"},{"name":"Cd","range":"(0,007 – 10,0) mg/l"},{"name":"Co","range":"(0,008 – 10,0) mg/l"},{"name":"Cr","range":"(0,015 – 10,0) mg/l"},{"name":"Cu","range":"(0,014 – 10,0) mg/l"},{"name":"K","range":"(0,7 – 500) mg/l"},{"name":"Mg","range":"(0,030 – 1100)mg/l"},{"name":"Mo","range":"(0,008 – 100) mg/l"},{"name":"Mn","range":"(0,006 – 10,0) mg/l"},{"name":"Na","range":"(1,0 – 500) mg/l"},{"name":"Ni","range":"(0,008 – 10,0) mg/l"},{"name":"Pb","range":"(0,020 – 1000) mg/l"},{"name":"Sr","range":"(0,019 – 10,0) mg/l"},{"name":"V","range":"(0,007– 10,0) mg/l"},{"name":"Zn","range":"(0,007 – 10,0) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie pierwiastków\nZakres:\nB (0,014 – 100) mg/l\nBa (0,010 – 10,0) mg/l\nCa (5,0 – 4600) mg/l\nCd (0,007 – 10,0) mg/l\nCo (0,008 – 10,0) mg/l\nCr (0,015 – 10,0) mg/l\nCu (0,014 – 10,0) mg/l\nK (0,7 – 500) mg/l\nMg (0,030 – 1100)mg/l\nMo (0,008 – 100) mg/l\nMn (0,006 – 10,0) mg/l\nNa (1,0 – 500) mg/l\nNi (0,008 – 10,0) mg/l\nPb (0,020 – 1000) mg/l\nSr (0,019 – 10,0) mg/l\nV (0,007– 10,0) mg/l\nZn (0,007 – 10,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN 12457-4:2006 | PN-EN ISO 11885:2009","norm_bases":["PN-EN 12457-4:2006","PN-EN ISO 11885:2009"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 21, 10 01 24, 10 01 25, 10 01 26, 10 01 80, 10 01 82, 17 06 04, 17 09 04, 19 09 02, 19 09 03, 19 09 04, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Produkt odsiarczania, Popiół z torfu i drewna Stężenie pierwiastków\nZakres:\nB (0,014 – 100) mg/l\nBa (0,010 – 10,0) mg/l\nCa (5,0 – 4600) mg/l\nCd (0,007 – 10,0) mg/l\nCo (0,008 – 10,0) mg/l\nCr (0,015 – 10,0) mg/l\nCu (0,014 – 10,0) mg/l\nK (0,7 – 500) mg/l\nMg (0,030 – 1100)mg/l\nMo (0,008 – 100) mg/l\nMn (0,006 – 10,0) mg/l\nNa (1,0 – 500) mg/l\nNi (0,008 – 10,0) mg/l\nPb (0,020 – 1000) mg/l\nSr (0,019 – 10,0) mg/l\nV (0,007– 10,0) mg/l\nZn (0,007 – 10,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN 12457-4:2006 | PN-EN ISO 11885:2009 Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 21, 10 01 24, 10 01 25, 10 01 26, 10 01 80, 10 01 82, 17 06 04, 17 09 04, 19 09 02, 19 09 03, 19 09 04, Popiol, zuzel, Mieszanka popiolowo zuzlowa, Popiol z produktami odsiarczania - lotny, Popiol z produktami odsiarczania - fluidalny, Piaski ze zloz fluidalnych, Produkt odsiarczania, Popiol z torfu i drewna Stezenie pierwiastkow\nZakres:\nB (0,014 – 100) mg/l\nBa (0,010 – 10,0) mg/l\nCa (5,0 – 4600) mg/l\nCd (0,007 – 10,0) mg/l\nCo (0,008 – 10,0) mg/l\nCr (0,015 – 10,0) mg/l\nCu (0,014 – 10,0) mg/l\nK (0,7 – 500) mg/l\nMg (0,030 – 1100)mg/l\nMo (0,008 – 100) mg/l\nMn (0,006 – 10,0) mg/l\nNa (1,0 – 500) mg/l\nNi (0,008 – 10,0) mg/l\nPb (0,020 – 1000) mg/l\nSr (0,019 – 10,0) mg/l\nV (0,007– 10,0) mg/l\nZn (0,007 – 10,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN 12457-4:2006 | PN-EN ISO 11885:2009","categories":["environment"],"row_index":124,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element concentration","parameters_en":[{"name":"B","range":"(0,014 – 100) mg/l"},{"name":"Ba","range":"(0,010 – 10,0) mg/l"},{"name":"Ca","range":"(5,0 – 4600) mg/l"},{"name":"Cd","range":"(0,007 – 10,0) mg/l"},{"name":"Co","range":"(0,008 – 10,0) mg/l"},{"name":"Cr","range":"(0,015 – 10,0) mg/l"},{"name":"Cu","range":"(0,014 – 10,0) mg/l"},{"name":"K","range":"(0,7 – 500) mg/l"},{"name":"Mg","range":"(0,030 – 1100)mg/l"},{"name":"Mo","range":"(0,008 – 100) mg/l"},{"name":"Mn","range":"(0,006 – 10,0) mg/l"},{"name":"Na","range":"(1,0 – 500) mg/l"},{"name":"Ni","range":"(0,008 – 10,0) mg/l"},{"name":"Pb","range":"(0,020 – 1000) mg/l"},{"name":"Sr","range":"(0,019 – 10,0) mg/l"},{"name":"V","range":"(0,007– 10,0) mg/l"},{"name":"Zn","range":"(0,007 – 10,0) mg/l"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Element concentration Inductively coupled plasma optical emission spectrometry (ICP-OES) waste codes according to the Regulation of the Minister of Climate on the waste catalogue. B Ba Ca Cd Co Cr Cu K Mg Mo Mn Na Ni Pb Sr V Zn PN-EN 12457-4:2006 | PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","methodology_zh":"元素浓度","parameters_zh":[{"name":"B","range":"(0,014 – 100) mg/l"},{"name":"Ba","range":"(0,010 – 10,0) mg/l"},{"name":"Ca","range":"(5,0 – 4600) mg/l"},{"name":"Cd","range":"(0,007 – 10,0) mg/l"},{"name":"Co","range":"(0,008 – 10,0) mg/l"},{"name":"Cr","range":"(0,015 – 10,0) mg/l"},{"name":"Cu","range":"(0,014 – 10,0) mg/l"},{"name":"K","range":"(0,7 – 500) mg/l"},{"name":"Mg","range":"(0,030 – 1100)mg/l"},{"name":"Mo","range":"(0,008 – 100) mg/l"},{"name":"Mn","range":"(0,006 – 10,0) mg/l"},{"name":"Na","range":"(1,0 – 500) mg/l"},{"name":"Ni","range":"(0,008 – 10,0) mg/l"},{"name":"Pb","range":"(0,020 – 1000) mg/l"},{"name":"Sr","range":"(0,019 – 10,0) mg/l"},{"name":"V","range":"(0,007– 10,0) mg/l"},{"name":"Zn","range":"(0,007 – 10,0) mg/l"}],"search_zh":"元素浓度 电感耦合等离子体原子发射光谱法（ICP-OES） 依据气候部长关于废物目录的条例的废物代码。 B Ba Ca Cd Co Cr Cu K Mg Mo Mn Na Ni Pb Sr V Zn PN-EN 12457-4:2006 | PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。"},{"_id":"6a837a57af14b9c0e7b1fdca","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 21, 10 01 24, 10 01 25, 10 01 26, 10 01 80, 10 01 82, 17 06 04, 17 09 04, 19 09 02, 19 09 03, 19 09 04, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Produkt odsiarczania, Popiół z torfu i drewna","methodology":"Stężenie pierwiastków","parameters":[{"name":"B","range":"(0,014 – 100) mg/l"},{"name":"Ba","range":"(0,010 – 10,0) mg/l"},{"name":"Ca","range":"(5,0 – 4600) mg/l"},{"name":"Cd","range":"(0,007 – 10,0) mg/l"},{"name":"Co","range":"(0,008 – 10,0) mg/l"},{"name":"Cr","range":"(0,015 – 10,0) mg/l"},{"name":"Cu","range":"(0,014 – 10,0) mg/l"},{"name":"K","range":"(0,7 – 500) mg/l"},{"name":"Mg","range":"(0,030 – 1100) mg/l"},{"name":"Mo","range":"(0,008 – 100) mg/l"},{"name":"Mn","range":"(0,006 – 10,0) mg/l"},{"name":"Na","range":"(1,0 – 500) mg/l"},{"name":"Ni","range":"(0,008 – 10,0) mg/l"},{"name":"Pb","range":"(0,020 – 1000) mg/l"},{"name":"Sr","range":"(0,019 – 10,0) mg/l"},{"name":"V","range":"(0,007– 10,0) mg/l"},{"name":"Zn","range":"(0,007 – 10,0) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie pierwiastków\nZakres:\nB (0,014 – 100) mg/l\nBa (0,010 – 10,0) mg/l\nCa (5,0 – 4600) mg/l\nCd (0,007 – 10,0) mg/l\nCo (0,008 – 10,0) mg/l\nCr (0,015 – 10,0) mg/l\nCu (0,014 – 10,0) mg/l\nK (0,7 – 500) mg/l\nMg (0,030 – 1100) mg/l\nMo (0,008 – 100) mg/l\nMn (0,006 – 10,0) mg/l\nNa (1,0 – 500) mg/l\nNi (0,008 – 10,0) mg/l\nPb (0,020 – 1000) mg/l\nSr (0,019 – 10,0) mg/l\nV (0,007– 10,0) mg/l\nZn (0,007 – 10,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-93/G-11010 | PN-EN ISO 11885:2009","norm_bases":["PN-93/G-11010","PN-EN ISO 11885:2009"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 21, 10 01 24, 10 01 25, 10 01 26, 10 01 80, 10 01 82, 17 06 04, 17 09 04, 19 09 02, 19 09 03, 19 09 04, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Produkt odsiarczania, Popiół z torfu i drewna Stężenie pierwiastków\nZakres:\nB (0,014 – 100) mg/l\nBa (0,010 – 10,0) mg/l\nCa (5,0 – 4600) mg/l\nCd (0,007 – 10,0) mg/l\nCo (0,008 – 10,0) mg/l\nCr (0,015 – 10,0) mg/l\nCu (0,014 – 10,0) mg/l\nK (0,7 – 500) mg/l\nMg (0,030 – 1100) mg/l\nMo (0,008 – 100) mg/l\nMn (0,006 – 10,0) mg/l\nNa (1,0 – 500) mg/l\nNi (0,008 – 10,0) mg/l\nPb (0,020 – 1000) mg/l\nSr (0,019 – 10,0) mg/l\nV (0,007– 10,0) mg/l\nZn (0,007 – 10,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-93/G-11010 | PN-EN ISO 11885:2009 Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 21, 10 01 24, 10 01 25, 10 01 26, 10 01 80, 10 01 82, 17 06 04, 17 09 04, 19 09 02, 19 09 03, 19 09 04, Popiol, zuzel, Mieszanka popiolowo zuzlowa, Popiol z produktami odsiarczania - lotny, Popiol z produktami odsiarczania - fluidalny, Piaski ze zloz fluidalnych, Produkt odsiarczania, Popiol z torfu i drewna Stezenie pierwiastkow\nZakres:\nB (0,014 – 100) mg/l\nBa (0,010 – 10,0) mg/l\nCa (5,0 – 4600) mg/l\nCd (0,007 – 10,0) mg/l\nCo (0,008 – 10,0) mg/l\nCr (0,015 – 10,0) mg/l\nCu (0,014 – 10,0) mg/l\nK (0,7 – 500) mg/l\nMg (0,030 – 1100) mg/l\nMo (0,008 – 100) mg/l\nMn (0,006 – 10,0) mg/l\nNa (1,0 – 500) mg/l\nNi (0,008 – 10,0) mg/l\nPb (0,020 – 1000) mg/l\nSr (0,019 – 10,0) mg/l\nV (0,007– 10,0) mg/l\nZn (0,007 – 10,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-93/G-11010 | PN-EN ISO 11885:2009","categories":["environment"],"row_index":125,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element concentration","parameters_en":[{"name":"B","range":"(0,014 – 100) mg/l"},{"name":"Ba","range":"(0,010 – 10,0) mg/l"},{"name":"Ca","range":"(5,0 – 4600) mg/l"},{"name":"Cd","range":"(0,007 – 10,0) mg/l"},{"name":"Co","range":"(0,008 – 10,0) mg/l"},{"name":"Cr","range":"(0,015 – 10,0) mg/l"},{"name":"Cu","range":"(0,014 – 10,0) mg/l"},{"name":"K","range":"(0,7 – 500) mg/l"},{"name":"Mg","range":"(0,030 – 1100) mg/l"},{"name":"Mo","range":"(0,008 – 100) mg/l"},{"name":"Mn","range":"(0,006 – 10,0) mg/l"},{"name":"Na","range":"(1,0 – 500) mg/l"},{"name":"Ni","range":"(0,008 – 10,0) mg/l"},{"name":"Pb","range":"(0,020 – 1000) mg/l"},{"name":"Sr","range":"(0,019 – 10,0) mg/l"},{"name":"V","range":"(0,007– 10,0) mg/l"},{"name":"Zn","range":"(0,007 – 10,0) mg/l"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Element concentration Inductively coupled plasma optical emission spectrometry (ICP-OES) waste codes according to the Regulation of the Minister of Climate on the waste catalogue. B Ba Ca Cd Co Cr Cu K Mg Mo Mn Na Ni Pb Sr V Zn PN-93/G-11010 | PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","methodology_zh":"元素浓度","parameters_zh":[{"name":"B","range":"(0,014 – 100) mg/l"},{"name":"Ba","range":"(0,010 – 10,0) mg/l"},{"name":"Ca","range":"(5,0 – 4600) mg/l"},{"name":"Cd","range":"(0,007 – 10,0) mg/l"},{"name":"Co","range":"(0,008 – 10,0) mg/l"},{"name":"Cr","range":"(0,015 – 10,0) mg/l"},{"name":"Cu","range":"(0,014 – 10,0) mg/l"},{"name":"K","range":"(0,7 – 500) mg/l"},{"name":"Mg","range":"(0,030 – 1100) mg/l"},{"name":"Mo","range":"(0,008 – 100) mg/l"},{"name":"Mn","range":"(0,006 – 10,0) mg/l"},{"name":"Na","range":"(1,0 – 500) mg/l"},{"name":"Ni","range":"(0,008 – 10,0) mg/l"},{"name":"Pb","range":"(0,020 – 1000) mg/l"},{"name":"Sr","range":"(0,019 – 10,0) mg/l"},{"name":"V","range":"(0,007– 10,0) mg/l"},{"name":"Zn","range":"(0,007 – 10,0) mg/l"}],"search_zh":"元素浓度 电感耦合等离子体原子发射光谱法（ICP-OES） 依据气候部长关于废物目录的条例的废物代码。 B Ba Ca Cd Co Cr Cu K Mg Mo Mn Na Ni Pb Sr V Zn PN-93/G-11010 | PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。"},{"_id":"6a837a57af14b9c0e7b1fdcb","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 21, 10 01 24, 10 01 25, 10 01 26, 10 01 80, 10 01 82, 17 06 04, 17 09 04, 19 09 02, 19 09 03, 19 09 04, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Produkt odsiarczania, Popiół z torfu i drewna","methodology":"Stężenie rtęci Hg","parameters":[{"name":"Zakres","range":"(0,050 – 300,00) μg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","techniques":["Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji"],"computed":[],"activity":"Stężenie rtęci Hg\nZakres (0,050 – 300,00) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","reference":"PN-EN 12457-4:2006 | PN-93/G-11010 | IB-DPA-09 wersja 04 z dnia 02-01-2026 r.","norm_bases":["PN-EN 12457-4:2006","PN-93/G-11010","IB-DPA-09 wersja 04 z dnia 02-01-2026 r."],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 21, 10 01 24, 10 01 25, 10 01 26, 10 01 80, 10 01 82, 17 06 04, 17 09 04, 19 09 02, 19 09 03, 19 09 04, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Produkt odsiarczania, Popiół z torfu i drewna Stężenie rtęci Hg\nZakres (0,050 – 300,00) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji PN-EN 12457-4:2006 | PN-93/G-11010 | IB-DPA-09 wersja 04 z dnia 02-01-2026 r. Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 21, 10 01 24, 10 01 25, 10 01 26, 10 01 80, 10 01 82, 17 06 04, 17 09 04, 19 09 02, 19 09 03, 19 09 04, Popiol, zuzel, Mieszanka popiolowo zuzlowa, Popiol z produktami odsiarczania - lotny, Popiol z produktami odsiarczania - fluidalny, Piaski ze zloz fluidalnych, Produkt odsiarczania, Popiol z torfu i drewna Stezenie rteci Hg\nZakres (0,050 – 300,00) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z technika amalgamacji PN-EN 12457-4:2006 | PN-93/G-11010 | IB-DPA-09 wersja 04 z dnia 02-01-2026 r.","categories":["environment"],"row_index":126,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury Hg concentration","parameters_en":[{"name":"Range","range":"(0,050 – 300,00) μg/l"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Mercury Hg concentration Atomic absorption spectrometry with amalgamation technique waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Range PN-EN 12457-4:2006 | PN-93/G-11010 | IB-DPA-09 wersja 04 z dnia 02-01-2026 r.","technique_en":"Atomic absorption spectrometry with amalgamation technique","parameters_zh":[{"name":"范围","range":"(0,050 – 300,00) μg/l"}],"search_zh":"原子吸收光谱法（汞齐化技术） 依据气候部长关于废物目录的条例的废物代码。 范围 PN-EN 12457-4:2006 | PN-93/G-11010 | IB-DPA-09 wersja 04 z dnia 02-01-2026 r.","technique_zh":"原子吸收光谱法（汞齐化技术）","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。"},{"_id":"6a837a57af14b9c0e7b1fdcc","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 05 04, 20 02 01","methodology":"Całkowite substancje rozpuszczone (TDS)","parameters":[{"name":"Zakres","range":"(10,0 – 20000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Całkowite substancje rozpuszczone (TDS)\nZakres (10,0 – 20000) mg/l\nMetoda wagowa","reference":"PN-EN 12457-4:2006 | PN-EN 15216:2022-03","norm_bases":["PN-EN 12457-4:2006","PN-EN 15216:2022-03"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 05 04, 20 02 01 Całkowite substancje rozpuszczone (TDS)\nZakres (10,0 – 20000) mg/l\nMetoda wagowa PN-EN 12457-4:2006 | PN-EN 15216:2022-03 Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 05 04, 20 02 01 Calkowite substancje rozpuszczone (TDS)\nZakres (10,0 – 20000) mg/l\nMetoda wagowa PN-EN 12457-4:2006 | PN-EN 15216:2022-03","categories":["environment"],"row_index":127,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total dissolved solids (TDS)","parameters_en":[{"name":"Range","range":"(10,0 – 20000) mg/l"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Total dissolved solids (TDS) Gravimetric method waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Range PN-EN 12457-4:2006 | PN-EN 15216:2022-03","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(10,0 – 20000) mg/l"}],"search_zh":"溶解性总固体（TDS） 重量法 依据气候部长关于废物目录的条例的废物代码。 范围 PN-EN 12457-4:2006 | PN-EN 15216:2022-03","technique_zh":"重量法","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。","methodology_zh":"溶解性总固体（TDS）"},{"_id":"6a837a57af14b9c0e7b1fdcd","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 05 04, 20 02 01","methodology":"Stężenie anionów","parameters":[{"name":"Chlorki","range":"(0,05 - 18000) mg/l"},{"name":"Siarczany","range":"(0,05 - 6000) mg/l"},{"name":"Fluorki","range":"(0,01 – 27,0) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie anionów\nZakres:\nChlorki (0,05 - 18000) mg/l\nSiarczany (0,05 - 6000) mg/l\nFluorki (0,01 – 27,0) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN 12457-4:2006 | PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN 12457-4:2006","PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 05 04, 20 02 01 Stężenie anionów\nZakres:\nChlorki (0,05 - 18000) mg/l\nSiarczany (0,05 - 6000) mg/l\nFluorki (0,01 – 27,0) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN 12457-4:2006 | PN-EN ISO 10304-1:2009+AC:2012 Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 05 04, 20 02 01 Stezenie anionow\nZakres:\nChlorki (0,05 - 18000) mg/l\nSiarczany (0,05 - 6000) mg/l\nFluorki (0,01 – 27,0) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN 12457-4:2006 | PN-EN ISO 10304-1:2009+AC:2012","categories":["environment"],"row_index":128,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Anion concentrations","parameters_en":[{"name":"Chlorides","range":"(0,05 - 18000) mg/l"},{"name":"Sulfates","range":"(0,05 - 6000) mg/l"},{"name":"Fluorides","range":"(0,01 – 27,0) mg/l"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Anion concentrations Ion chromatography with conductometric detection (IC-CD) waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Chlorides Sulfates Fluorides PN-EN 12457-4:2006 | PN-EN ISO 10304-1:2009+AC:2012","technique_en":"Ion chromatography with conductometric detection (IC-CD)","methodology_zh":"阴离子浓度","parameters_zh":[{"name":"氯化物","range":"(0,05 - 18000) mg/l"},{"name":"硫酸盐","range":"(0,05 - 6000) mg/l"},{"name":"氟化物","range":"(0,01 – 27,0) mg/l"}],"search_zh":"阴离子浓度 离子色谱-电导检测法（IC-CD） 依据气候部长关于废物目录的条例的废物代码。 氯化物 硫酸盐 氟化物 PN-EN 12457-4:2006 | PN-EN ISO 10304-1:2009+AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。"},{"_id":"6a837a57af14b9c0e7b1fdce","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 05 04, 20 02 01","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 – 13,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 – 13,0\nMetoda potencjometryczna","reference":"PN-EN 12457-4:2006 | PN-EN ISO 10523:2012","norm_bases":["PN-EN 12457-4:2006","PN-EN ISO 10523:2012"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 05 04, 20 02 01 pH\nZakres 4,0 – 13,0\nMetoda potencjometryczna PN-EN 12457-4:2006 | PN-EN ISO 10523:2012 Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 05 04, 20 02 01 pH\nZakres 4,0 – 13,0\nMetoda potencjometryczna PN-EN 12457-4:2006 | PN-EN ISO 10523:2012","categories":["environment"],"row_index":129,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 – 13,0"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"pH Potentiometric method waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Range PN-EN 12457-4:2006 | PN-EN ISO 10523:2012","technique_en":"Potentiometric method","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 13,0"}],"search_zh":"pH 值 电位法 依据气候部长关于废物目录的条例的废物代码。 范围 PN-EN 12457-4:2006 | PN-EN ISO 10523:2012","technique_zh":"电位法","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。"},{"_id":"6a837a57af14b9c0e7b1fdcf","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 05 04, 20 02 01","methodology":"Stężenie pierwiastków, As - (0,008 – 2,00) mg/l, Ba - (0,010 – 10,0) mg/l, Zn - (0,007 – 10,0) mg/l, Cd - (0,007 – 10,0) mg/l, Cu - (0,014 – 10,0) mg/l, Cr - (0,015 – 10,0) mg/l, Pb - (0,020 – 1000) mg/l, Ni - (0,008 – 10,0) mg/l, Sb - (0,016 – 2,00) mg/l, Se - (0,006 – 2,00) mg/l, Mo - (0,008 – 100) mg/l","parameters":[],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie pierwiastków, As - (0,008 – 2,00) mg/l, Ba - (0,010 – 10,0) mg/l, Zn - (0,007 – 10,0) mg/l, Cd - (0,007 – 10,0) mg/l, Cu - (0,014 – 10,0) mg/l, Cr - (0,015 – 10,0) mg/l, Pb - (0,020 – 1000) mg/l, Ni - (0,008 – 10,0) mg/l, Sb - (0,016 – 2,00) mg/l, Se - (0,006 – 2,00) mg/l, Mo - (0,008 – 100) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN 12457-4:2006 | PN-EN ISO 11885:2009","norm_bases":["PN-EN 12457-4:2006","PN-EN ISO 11885:2009"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 05 04, 20 02 01 Stężenie pierwiastków, As - (0,008 – 2,00) mg/l, Ba - (0,010 – 10,0) mg/l, Zn - (0,007 – 10,0) mg/l, Cd - (0,007 – 10,0) mg/l, Cu - (0,014 – 10,0) mg/l, Cr - (0,015 – 10,0) mg/l, Pb - (0,020 – 1000) mg/l, Ni - (0,008 – 10,0) mg/l, Sb - (0,016 – 2,00) mg/l, Se - (0,006 – 2,00) mg/l, Mo - (0,008 – 100) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN 12457-4:2006 | PN-EN ISO 11885:2009 Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 05 04, 20 02 01 Stezenie pierwiastkow, As - (0,008 – 2,00) mg/l, Ba - (0,010 – 10,0) mg/l, Zn - (0,007 – 10,0) mg/l, Cd - (0,007 – 10,0) mg/l, Cu - (0,014 – 10,0) mg/l, Cr - (0,015 – 10,0) mg/l, Pb - (0,020 – 1000) mg/l, Ni - (0,008 – 10,0) mg/l, Sb - (0,016 – 2,00) mg/l, Se - (0,006 – 2,00) mg/l, Mo - (0,008 – 100) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN 12457-4:2006 | PN-EN ISO 11885:2009","categories":["environment"],"row_index":130,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element concentrations, As - (0,008 – 2,00) mg/l, Ba - (0,010 – 10,0) mg/l, Zn - (0,007 – 10,0) mg/l, Cd - (0,007 – 10,0) mg/l, Cu - (0,014 – 10,0) mg/l, Cr - (0,015 – 10,0) mg/l, Pb - (0,020 – 1000) mg/l, Ni - (0,008 – 10,0) mg/l, Sb - (0,016 – 2,00) mg/l, Se - (0,006 – 2,00) mg/l, Mo - (0,008 – 100) mg/l","regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Element concentrations, As - (0,008 – 2,00) mg/l, Ba - (0,010 – 10,0) mg/l, Zn - (0,007 – 10,0) mg/l, Cd - (0,007 – 10,0) mg/l, Cu - (0,014 – 10,0) mg/l, Cr - (0,015 – 10,0) mg/l, Pb - (0,020 – 1000) mg/l, Ni - (0,008 – 10,0) mg/l, Sb - (0,016 – 2,00) mg/l, Se - (0,006 – 2,00) mg/l, Mo - (0,008 – 100) mg/l Inductively coupled plasma optical emission spectrometry (ICP-OES) waste codes according to the Regulation of the Minister of Climate on the waste catalogue. PN-EN 12457-4:2006 | PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","search_zh":"电感耦合等离子体原子发射光谱法（ICP-OES） 依据气候部长关于废物目录的条例的废物代码。 PN-EN 12457-4:2006 | PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。"},{"_id":"6a837a57af14b9c0e7b1fdd0","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Materiał budowalny: gips","methodology":"Zawartość wilgoci","parameters":[{"name":"Zakres","range":"(0,1 – 50,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci\nZakres (0,1 – 50,0) %\nMetoda wagowa","reference":"IB-DPA-29 wersja 06 z dnia 02-01-2026 r.","norm_bases":["IB-DPA-29 wersja 06 z dnia 02-01-2026 r."],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiał budowalny: gips Zawartość wilgoci\nZakres (0,1 – 50,0) %\nMetoda wagowa IB-DPA-29 wersja 06 z dnia 02-01-2026 r. Material budowalny: gips Zawartosc wilgoci\nZakres (0,1 – 50,0) %\nMetoda wagowa IB-DPA-29 wersja 06 z dnia 02-01-2026 r.","categories":["materials"],"row_index":131,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Moisture content","parameters_en":[{"name":"Range","range":"(0,1 – 50,0) %"}],"search_en":"Construction material: gypsum Moisture content Gravimetric method Range IB-DPA-29 wersja 06 z dnia 02-01-2026 r.","technique_en":"Gravimetric method","test_object_en":"Construction material: gypsum","parameters_zh":[{"name":"范围","range":"(0,1 – 50,0) %"}],"search_zh":"建筑材料：石膏 水分含量 重量法 范围 IB-DPA-29 wersja 06 z dnia 02-01-2026 r.","technique_zh":"重量法","methodology_zh":"水分含量","test_object_zh":"建筑材料：石膏"},{"_id":"6a837a57af14b9c0e7b1fdd1","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Materiał budowalny: gips","methodology":"Zawartość CaSO4 x 2H2O","parameters":[{"name":"Zakres","range":"(50,0 – 99,9) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość CaSO4 x 2H2O\nZakres (50,0 – 99,9) %\nMetoda wagowa","reference":"IB-DPA-30 wersja 06 z dnia 02-01-2026 r.","norm_bases":["IB-DPA-30 wersja 06 z dnia 02-01-2026 r."],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiał budowalny: gips Zawartość CaSO4 x 2H2O\nZakres (50,0 – 99,9) %\nMetoda wagowa IB-DPA-30 wersja 06 z dnia 02-01-2026 r. Material budowalny: gips Zawartosc CaSO4 x 2H2O\nZakres (50,0 – 99,9) %\nMetoda wagowa IB-DPA-30 wersja 06 z dnia 02-01-2026 r.","categories":["materials"],"row_index":132,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"CaSO4 x 2H2O content","parameters_en":[{"name":"Range","range":"(50,0 – 99,9) %"}],"search_en":"Construction material: gypsum CaSO4 x 2H2O content Gravimetric method Range IB-DPA-30 wersja 06 z dnia 02-01-2026 r.","technique_en":"Gravimetric method","test_object_en":"Construction material: gypsum","parameters_zh":[{"name":"范围","range":"(50,0 – 99,9) %"}],"search_zh":"建筑材料：石膏 重量法 范围 IB-DPA-30 wersja 06 z dnia 02-01-2026 r.","technique_zh":"重量法","test_object_zh":"建筑材料：石膏"},{"_id":"6a837a57af14b9c0e7b1fdd2","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Materiał budowalny: gips","methodology":"Zawartość CaCO3","parameters":[{"name":"Zakres","range":"(0,40 – 35,00) % CaCO3"}],"technique":"Metoda miareczkowania potencjometrycznego","techniques":["Metoda miareczkowania potencjometrycznego"],"computed":[],"activity":"Zawartość CaCO3\nZakres (0,40 – 35,00) % CaCO3\nMetoda miareczkowania potencjometrycznego","reference":"IB-DPA-32 wersja 06 z dnia 02-01-2026 r.","norm_bases":["IB-DPA-32 wersja 06 z dnia 02-01-2026 r."],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiał budowalny: gips Zawartość CaCO3\nZakres (0,40 – 35,00) % CaCO3\nMetoda miareczkowania potencjometrycznego IB-DPA-32 wersja 06 z dnia 02-01-2026 r. Material budowalny: gips Zawartosc CaCO3\nZakres (0,40 – 35,00) % CaCO3\nMetoda miareczkowania potencjometrycznego IB-DPA-32 wersja 06 z dnia 02-01-2026 r.","categories":["materials"],"row_index":133,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"CaCO3 content","parameters_en":[{"name":"Range","range":"(0,40 – 35,00) % CaCO3"}],"search_en":"Construction material: gypsum CaCO3 content Potentiometric titration method Range IB-DPA-32 wersja 06 z dnia 02-01-2026 r.","technique_en":"Potentiometric titration method","test_object_en":"Construction material: gypsum","parameters_zh":[{"name":"范围","range":"(0,40 – 35,00) % CaCO3"}],"search_zh":"建筑材料：石膏 CaCO3 含量 电位滴定法 范围 IB-DPA-32 wersja 06 z dnia 02-01-2026 r.","technique_zh":"电位滴定法","test_object_zh":"建筑材料：石膏","methodology_zh":"CaCO3 含量"},{"_id":"6a837a57af14b9c0e7b1fdd3","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Materiał budowalny: gips","methodology":"Zawartość chlorków","parameters":[{"name":"Zakres","range":"(0,0010 – 0,16) %"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość chlorków\nZakres (0,0010 – 0,16) %\nMetoda spektrofotometryczna","reference":"IB-DPA-33 wersja 06 z dnia 02-01-2026 r.","norm_bases":["IB-DPA-33 wersja 06 z dnia 02-01-2026 r."],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiał budowalny: gips Zawartość chlorków\nZakres (0,0010 – 0,16) %\nMetoda spektrofotometryczna IB-DPA-33 wersja 06 z dnia 02-01-2026 r. Material budowalny: gips Zawartosc chlorkow\nZakres (0,0010 – 0,16) %\nMetoda spektrofotometryczna IB-DPA-33 wersja 06 z dnia 02-01-2026 r.","categories":["materials"],"row_index":134,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride content","parameters_en":[{"name":"Range","range":"(0,0010 – 0,16) %"}],"search_en":"Construction material: gypsum Chloride content Spectrophotometric method Range IB-DPA-33 wersja 06 z dnia 02-01-2026 r.","technique_en":"Spectrophotometric method","test_object_en":"Construction material: gypsum","parameters_zh":[{"name":"范围","range":"(0,0010 – 0,16) %"}],"search_zh":"建筑材料：石膏 氯化物含量 分光光度法 范围 IB-DPA-33 wersja 06 z dnia 02-01-2026 r.","technique_zh":"分光光度法","methodology_zh":"氯化物含量","test_object_zh":"建筑材料：石膏"},{"_id":"6a837a57af14b9c0e7b1fdd4","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Materiał budowalny: gips","methodology":"Zawartość metali i tlenków metali","parameters":[{"name":"Fe","range":"(20,0 – 1000) mg/kg"},{"name":"Al","range":"(20,0 – 1000) mg/kg"},{"name":"Mg","range":"(69,0 – 10000) mg/kg"},{"name":"Na","range":"(30,0 – 10000) mg/kg"},{"name":"K","range":"(120 – 10000) mg/kg"},{"name":"Fe2O3","range":"(0,003 – 1,00) %"},{"name":"Al2O3","range":"(0,004 – 1,00) %"},{"name":"MgO","range":"(0,011 – 2,00) %"},{"name":"Na2O","range":"(0,004 – 1,00) %"},{"name":"K2O","range":"(0,015 – 1,00) %"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość metali i tlenków metali\nZakres:\nFe (20,0 – 1000) mg/kg\nAl (20,0 – 1000) mg/kg\nMg (69,0 – 10000) mg/kg\nNa (30,0 – 10000) mg/kg\nK (120 – 10000) mg/kg\nFe2O3 (0,003 – 1,00) %\nAl2O3 (0,004 – 1,00) %\nMgO (0,011 – 2,00) %\nNa2O (0,004 – 1,00) %\nK2O (0,015 – 1,00) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"IB-DPA-35 wersja 06 z dnia 02-01-2026 r.","norm_bases":["IB-DPA-35 wersja 06 z dnia 02-01-2026 r."],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiał budowalny: gips Zawartość metali i tlenków metali\nZakres:\nFe (20,0 – 1000) mg/kg\nAl (20,0 – 1000) mg/kg\nMg (69,0 – 10000) mg/kg\nNa (30,0 – 10000) mg/kg\nK (120 – 10000) mg/kg\nFe2O3 (0,003 – 1,00) %\nAl2O3 (0,004 – 1,00) %\nMgO (0,011 – 2,00) %\nNa2O (0,004 – 1,00) %\nK2O (0,015 – 1,00) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) IB-DPA-35 wersja 06 z dnia 02-01-2026 r. Material budowalny: gips Zawartosc metali i tlenkow metali\nZakres:\nFe (20,0 – 1000) mg/kg\nAl (20,0 – 1000) mg/kg\nMg (69,0 – 10000) mg/kg\nNa (30,0 – 10000) mg/kg\nK (120 – 10000) mg/kg\nFe2O3 (0,003 – 1,00) %\nAl2O3 (0,004 – 1,00) %\nMgO (0,011 – 2,00) %\nNa2O (0,004 – 1,00) %\nK2O (0,015 – 1,00) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) IB-DPA-35 wersja 06 z dnia 02-01-2026 r.","categories":["materials"],"row_index":135,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of metals and metal oxides","parameters_en":[{"name":"Fe","range":"(20,0 – 1000) mg/kg"},{"name":"Al","range":"(20,0 – 1000) mg/kg"},{"name":"Mg","range":"(69,0 – 10000) mg/kg"},{"name":"Na","range":"(30,0 – 10000) mg/kg"},{"name":"K","range":"(120 – 10000) mg/kg"},{"name":"Fe2O3","range":"(0,003 – 1,00) %"},{"name":"Al2O3","range":"(0,004 – 1,00) %"},{"name":"MgO","range":"(0,011 – 2,00) %"},{"name":"Na2O","range":"(0,004 – 1,00) %"},{"name":"K2O","range":"(0,015 – 1,00) %"}],"search_en":"Construction material: gypsum Content of metals and metal oxides Inductively coupled plasma optical emission spectrometry (ICP-OES) Fe Al Mg Na K Fe2O3 Al2O3 MgO Na2O K2O IB-DPA-35 wersja 06 z dnia 02-01-2026 r.","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Construction material: gypsum","search_zh":"建筑材料：石膏 电感耦合等离子体原子发射光谱法（ICP-OES） Fe Al Mg Na K Fe2O3 Al2O3 MgO Na2O K2O IB-DPA-35 wersja 06 z dnia 02-01-2026 r.","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","parameters_zh":[{"name":"Fe","range":"(20,0 – 1000) mg/kg"},{"name":"Al","range":"(20,0 – 1000) mg/kg"},{"name":"Mg","range":"(69,0 – 10000) mg/kg"},{"name":"Na","range":"(30,0 – 10000) mg/kg"},{"name":"K","range":"(120 – 10000) mg/kg"},{"name":"Fe2O3","range":"(0,003 – 1,00) %"},{"name":"Al2O3","range":"(0,004 – 1,00) %"},{"name":"MgO","range":"(0,011 – 2,00) %"},{"name":"Na2O","range":"(0,004 – 1,00) %"},{"name":"K2O","range":"(0,015 – 1,00) %"}],"test_object_zh":"建筑材料：石膏"},{"_id":"6a837a57af14b9c0e7b1fdd5","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Materiał budowalny: gips","methodology":"Zawartość metali","parameters":[{"name":"Pb","range":"(5,0 – 200) mg/kg"},{"name":"Mo","range":"(8,0 – 200) mg/kg"},{"name":"Cr","range":"(10,0 – 200) mg/kg"},{"name":"Zn","range":"(7,0 – 200) mg/kg"},{"name":"Cd","range":"(7,0 – 200) mg/kg"},{"name":"Ni","range":"(8,0 – 200) mg/kg"},{"name":"Co","range":"(8,0 – 200) mg/kg"},{"name":"Mn","range":"(6,0 – 200) mg/kg"},{"name":"V","range":"(7,0 – 200) mg/kg"},{"name":"Cu","range":"(10,0 – 200) mg/kg"},{"name":"As","range":"(20,0 – 50,0) mg/kg"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość metali\nZakres:\nPb (5,0 – 200) mg/kg\nMo (8,0 – 200) mg/kg\nCr (10,0 – 200) mg/kg\nZn (7,0 – 200) mg/kg\nCd (7,0 – 200) mg/kg\nNi (8,0 – 200) mg/kg\nCo (8,0 – 200) mg/kg\nMn (6,0 – 200) mg/kg\nV (7,0 – 200) mg/kg\nCu (10,0 – 200) mg/kg\nAs (20,0 – 50,0) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"IB-DPA-35 wersja 06 z dnia 02-01-2026 r.","norm_bases":["IB-DPA-35 wersja 06 z dnia 02-01-2026 r."],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiał budowalny: gips Zawartość metali\nZakres:\nPb (5,0 – 200) mg/kg\nMo (8,0 – 200) mg/kg\nCr (10,0 – 200) mg/kg\nZn (7,0 – 200) mg/kg\nCd (7,0 – 200) mg/kg\nNi (8,0 – 200) mg/kg\nCo (8,0 – 200) mg/kg\nMn (6,0 – 200) mg/kg\nV (7,0 – 200) mg/kg\nCu (10,0 – 200) mg/kg\nAs (20,0 – 50,0) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) IB-DPA-35 wersja 06 z dnia 02-01-2026 r. Material budowalny: gips Zawartosc metali\nZakres:\nPb (5,0 – 200) mg/kg\nMo (8,0 – 200) mg/kg\nCr (10,0 – 200) mg/kg\nZn (7,0 – 200) mg/kg\nCd (7,0 – 200) mg/kg\nNi (8,0 – 200) mg/kg\nCo (8,0 – 200) mg/kg\nMn (6,0 – 200) mg/kg\nV (7,0 – 200) mg/kg\nCu (10,0 – 200) mg/kg\nAs (20,0 – 50,0) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) IB-DPA-35 wersja 06 z dnia 02-01-2026 r.","categories":["materials"],"row_index":136,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Metal content","parameters_en":[{"name":"Pb","range":"(5,0 – 200) mg/kg"},{"name":"Mo","range":"(8,0 – 200) mg/kg"},{"name":"Cr","range":"(10,0 – 200) mg/kg"},{"name":"Zn","range":"(7,0 – 200) mg/kg"},{"name":"Cd","range":"(7,0 – 200) mg/kg"},{"name":"Ni","range":"(8,0 – 200) mg/kg"},{"name":"Co","range":"(8,0 – 200) mg/kg"},{"name":"Mn","range":"(6,0 – 200) mg/kg"},{"name":"V","range":"(7,0 – 200) mg/kg"},{"name":"Cu","range":"(10,0 – 200) mg/kg"},{"name":"As","range":"(20,0 – 50,0) mg/kg"}],"search_en":"Construction material: gypsum Metal content Inductively coupled plasma optical emission spectrometry (ICP-OES) Pb Mo Cr Zn Cd Ni Co Mn V Cu As IB-DPA-35 wersja 06 z dnia 02-01-2026 r.","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Construction material: gypsum","parameters_zh":[{"name":"Pb","range":"(5,0 – 200) mg/kg"},{"name":"Mo","range":"(8,0 – 200) mg/kg"},{"name":"Cr","range":"(10,0 – 200) mg/kg"},{"name":"Zn","range":"(7,0 – 200) mg/kg"},{"name":"Cd","range":"(7,0 – 200) mg/kg"},{"name":"Ni","range":"(8,0 – 200) mg/kg"},{"name":"Co","range":"(8,0 – 200) mg/kg"},{"name":"Mn","range":"(6,0 – 200) mg/kg"},{"name":"V","range":"(7,0 – 200) mg/kg"},{"name":"Cu","range":"(10,0 – 200) mg/kg"},{"name":"As","range":"(20,0 – 50,0) mg/kg"}],"search_zh":"建筑材料：石膏 金属含量 电感耦合等离子体原子发射光谱法（ICP-OES） Pb Mo Cr Zn Cd Ni Co Mn V Cu As IB-DPA-35 wersja 06 z dnia 02-01-2026 r.","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","methodology_zh":"金属含量","test_object_zh":"建筑材料：石膏"},{"_id":"6a837a57af14b9c0e7b1fdd6","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Materiał budowalny: gips","methodology":"Zawartość krzemionki i części nierozpuszczalnych","parameters":[{"name":"Zakres","range":"(0,10 – 10,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość krzemionki i części nierozpuszczalnych\nZakres (0,10 – 10,0) %\nMetoda wagowa","reference":"IB-DPA-35 wersja 06 z dnia 02-01-2026 r.","norm_bases":["IB-DPA-35 wersja 06 z dnia 02-01-2026 r."],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiał budowalny: gips Zawartość krzemionki i części nierozpuszczalnych\nZakres (0,10 – 10,0) %\nMetoda wagowa IB-DPA-35 wersja 06 z dnia 02-01-2026 r. Material budowalny: gips Zawartosc krzemionki i czesci nierozpuszczalnych\nZakres (0,10 – 10,0) %\nMetoda wagowa IB-DPA-35 wersja 06 z dnia 02-01-2026 r.","categories":["materials"],"row_index":137,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Silica and insoluble matter content","parameters_en":[{"name":"Range","range":"(0,10 – 10,0) %"}],"search_en":"Construction material: gypsum Silica and insoluble matter content Gravimetric method Range IB-DPA-35 wersja 06 z dnia 02-01-2026 r.","technique_en":"Gravimetric method","test_object_en":"Construction material: gypsum","parameters_zh":[{"name":"范围","range":"(0,10 – 10,0) %"}],"search_zh":"建筑材料：石膏 重量法 范围 IB-DPA-35 wersja 06 z dnia 02-01-2026 r.","technique_zh":"重量法","test_object_zh":"建筑材料：石膏"},{"_id":"6a837a57af14b9c0e7b1fdd7","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Materiał budowalny: gips","methodology":"pH wyciągu wodnego","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH wyciągu wodnego\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"IB-DPA-38 wersja 06 z dnia 02-01-2026 r.","norm_bases":["IB-DPA-38 wersja 06 z dnia 02-01-2026 r."],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiał budowalny: gips pH wyciągu wodnego\nZakres 4,0 – 10,0\nMetoda potencjometryczna IB-DPA-38 wersja 06 z dnia 02-01-2026 r. Material budowalny: gips pH wyciagu wodnego\nZakres 4,0 – 10,0\nMetoda potencjometryczna IB-DPA-38 wersja 06 z dnia 02-01-2026 r.","categories":["materials"],"row_index":138,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH of the aqueous extract","parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"search_en":"Construction material: gypsum pH of the aqueous extract Potentiometric method Range IB-DPA-38 wersja 06 z dnia 02-01-2026 r.","technique_en":"Potentiometric method","test_object_en":"Construction material: gypsum","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"建筑材料：石膏 电位法 范围 IB-DPA-38 wersja 06 z dnia 02-01-2026 r.","technique_zh":"电位法","test_object_zh":"建筑材料：石膏"},{"_id":"6a837a57af14b9c0e7b1fdd8","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Materiał budowalny: gips","methodology":"Zawartość rtęci Hg","parameters":[{"name":"Zakres","range":"(0,0020 – 0,300) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","techniques":["Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji"],"computed":[],"activity":"Zawartość rtęci Hg\nZakres (0,0020 – 0,300) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","reference":"IB-DPA-09 wersja 04 z dnia 02-01-2026 r.","norm_bases":["IB-DPA-09 wersja 04 z dnia 02-01-2026 r."],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiał budowalny: gips Zawartość rtęci Hg\nZakres (0,0020 – 0,300) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji IB-DPA-09 wersja 04 z dnia 02-01-2026 r. Material budowalny: gips Zawartosc rteci Hg\nZakres (0,0020 – 0,300) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z technika amalgamacji IB-DPA-09 wersja 04 z dnia 02-01-2026 r.","categories":["materials"],"row_index":139,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury Hg content","parameters_en":[{"name":"Range","range":"(0,0020 – 0,300) mg/kg"}],"search_en":"Construction material: gypsum Mercury Hg content Atomic absorption spectrometry with amalgamation technique Range IB-DPA-09 wersja 04 z dnia 02-01-2026 r.","technique_en":"Atomic absorption spectrometry with amalgamation technique","test_object_en":"Construction material: gypsum","parameters_zh":[{"name":"范围","range":"(0,0020 – 0,300) mg/kg"}],"search_zh":"建筑材料：石膏 原子吸收光谱法（汞齐化技术） 范围 IB-DPA-09 wersja 04 z dnia 02-01-2026 r.","technique_zh":"原子吸收光谱法（汞齐化技术）","test_object_zh":"建筑材料：石膏"},{"_id":"6a837a57af14b9c0e7b1fdd9","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Wyroby chemiczne: kamień wapienny, w tym sorbenty wapniowe i węglanowe","methodology":"Zawartość wilgoci","parameters":[{"name":"Zakres","range":"(0,10 – 10,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci\nZakres (0,10 – 10,0) %\nMetoda wagowa","reference":"IB-DPA-40 wersja 06 z dnia 02-01-2026 r.","norm_bases":["IB-DPA-40 wersja 06 z dnia 02-01-2026 r."],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby chemiczne: kamień wapienny, w tym sorbenty wapniowe i węglanowe Zawartość wilgoci\nZakres (0,10 – 10,0) %\nMetoda wagowa IB-DPA-40 wersja 06 z dnia 02-01-2026 r. Wyroby chemiczne: kamien wapienny, w tym sorbenty wapniowe i weglanowe Zawartosc wilgoci\nZakres (0,10 – 10,0) %\nMetoda wagowa IB-DPA-40 wersja 06 z dnia 02-01-2026 r.","categories":["other"],"row_index":140,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Moisture content","parameters_en":[{"name":"Range","range":"(0,10 – 10,0) %"}],"search_en":"Chemical products: limestone, including calcium and carbonate sorbents Moisture content Gravimetric method Range IB-DPA-40 wersja 06 z dnia 02-01-2026 r.","technique_en":"Gravimetric method","test_object_en":"Chemical products: limestone, including calcium and carbonate sorbents","parameters_zh":[{"name":"范围","range":"(0,10 – 10,0) %"}],"search_zh":"化工产品：石灰石，含钙质与碳酸盐吸收剂 水分含量 重量法 范围 IB-DPA-40 wersja 06 z dnia 02-01-2026 r.","technique_zh":"重量法","methodology_zh":"水分含量","test_object_zh":"化工产品：石灰石，含钙质与碳酸盐吸收剂"},{"_id":"6a837a57af14b9c0e7b1fdda","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Wyroby chemiczne: kamień wapienny, w tym sorbenty wapniowe i węglanowe","methodology":"Zawartość CaCO3","parameters":[{"name":"Zakres","range":"(50,0 – 99,9) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość CaCO3\nZakres (50,0 – 99,9) %\nMetoda miareczkowa","reference":"IB-DPA-41 wersja 06 z dnia 02-01-2026 r.","norm_bases":["IB-DPA-41 wersja 06 z dnia 02-01-2026 r."],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby chemiczne: kamień wapienny, w tym sorbenty wapniowe i węglanowe Zawartość CaCO3\nZakres (50,0 – 99,9) %\nMetoda miareczkowa IB-DPA-41 wersja 06 z dnia 02-01-2026 r. Wyroby chemiczne: kamien wapienny, w tym sorbenty wapniowe i weglanowe Zawartosc CaCO3\nZakres (50,0 – 99,9) %\nMetoda miareczkowa IB-DPA-41 wersja 06 z dnia 02-01-2026 r.","categories":["other"],"row_index":141,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"CaCO3 content","parameters_en":[{"name":"Range","range":"(50,0 – 99,9) %"}],"search_en":"Chemical products: limestone, including calcium and carbonate sorbents CaCO3 content Titrimetric method Range IB-DPA-41 wersja 06 z dnia 02-01-2026 r.","technique_en":"Titrimetric method","test_object_en":"Chemical products: limestone, including calcium and carbonate sorbents","parameters_zh":[{"name":"范围","range":"(50,0 – 99,9) %"}],"search_zh":"化工产品：石灰石，含钙质与碳酸盐吸收剂 CaCO3 含量 滴定法 范围 IB-DPA-41 wersja 06 z dnia 02-01-2026 r.","technique_zh":"滴定法","test_object_zh":"化工产品：石灰石，含钙质与碳酸盐吸收剂","methodology_zh":"CaCO3 含量"},{"_id":"6a837a57af14b9c0e7b1fddb","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Wyroby chemiczne: kamień wapienny, w tym sorbenty wapniowe i węglanowe","methodology":"Zawartość metali i tlenków metali","parameters":[{"name":"Na","range":"(30,0 – 10000) mg/kg"},{"name":"K","range":"(120 – 10000) mg/kg"},{"name":"Na2O","range":"(0,004 – 1,00) %"},{"name":"K2O","range":"(0,015 – 1,00) %"},{"name":"Fe2O3","range":"(0,020 – 1,00) %"},{"name":"Fe","range":"(0,013 – 0,70) %"},{"name":"Al2O3","range":"(0,020 – 1,00) %"},{"name":"Al.","range":"(0,010 – 0,52) %"},{"name":"MgO","range":"(0,090 – 5,00) %"},{"name":"Mg","range":"(0,054 – 3,01) %"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość metali i tlenków metali\nZakres:\nNa (30,0 – 10000) mg/kg\nK (120 – 10000) mg/kg\nNa2O (0,004 – 1,00) %\nK2O (0,015 – 1,00) %\nFe2O3 (0,020 – 1,00) %\nFe (0,013 – 0,70) %\nAl2O3 (0,020 – 1,00) %\nAl. (0,010 – 0,52) %\nMgO (0,090 – 5,00) %\nMg (0,054 – 3,01) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"IB-DPA-43 wersja 06 z dnia 02-01-2026 r.","norm_bases":["IB-DPA-43 wersja 06 z dnia 02-01-2026 r."],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby chemiczne: kamień wapienny, w tym sorbenty wapniowe i węglanowe Zawartość metali i tlenków metali\nZakres:\nNa (30,0 – 10000) mg/kg\nK (120 – 10000) mg/kg\nNa2O (0,004 – 1,00) %\nK2O (0,015 – 1,00) %\nFe2O3 (0,020 – 1,00) %\nFe (0,013 – 0,70) %\nAl2O3 (0,020 – 1,00) %\nAl. (0,010 – 0,52) %\nMgO (0,090 – 5,00) %\nMg (0,054 – 3,01) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) IB-DPA-43 wersja 06 z dnia 02-01-2026 r. Wyroby chemiczne: kamien wapienny, w tym sorbenty wapniowe i weglanowe Zawartosc metali i tlenkow metali\nZakres:\nNa (30,0 – 10000) mg/kg\nK (120 – 10000) mg/kg\nNa2O (0,004 – 1,00) %\nK2O (0,015 – 1,00) %\nFe2O3 (0,020 – 1,00) %\nFe (0,013 – 0,70) %\nAl2O3 (0,020 – 1,00) %\nAl. (0,010 – 0,52) %\nMgO (0,090 – 5,00) %\nMg (0,054 – 3,01) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) IB-DPA-43 wersja 06 z dnia 02-01-2026 r.","categories":["materials"],"row_index":142,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of metals and metal oxides","parameters_en":[{"name":"Na","range":"(30,0 – 10000) mg/kg"},{"name":"K","range":"(120 – 10000) mg/kg"},{"name":"Na2O","range":"(0,004 – 1,00) %"},{"name":"K2O","range":"(0,015 – 1,00) %"},{"name":"Fe2O3","range":"(0,020 – 1,00) %"},{"name":"Fe","range":"(0,013 – 0,70) %"},{"name":"Al2O3","range":"(0,020 – 1,00) %"},{"name":"Al.","range":"(0,010 – 0,52) %"},{"name":"MgO","range":"(0,090 – 5,00) %"},{"name":"Mg","range":"(0,054 – 3,01) %"}],"search_en":"Chemical products: limestone, including calcium and carbonate sorbents Content of metals and metal oxides Inductively coupled plasma optical emission spectrometry (ICP-OES) Na K Na2O K2O Fe2O3 Fe Al2O3 Al. MgO Mg IB-DPA-43 wersja 06 z dnia 02-01-2026 r.","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Chemical products: limestone, including calcium and carbonate sorbents","search_zh":"化工产品：石灰石，含钙质与碳酸盐吸收剂 电感耦合等离子体原子发射光谱法（ICP-OES） Na K Na2O K2O Fe2O3 Fe Al2O3 MgO Mg IB-DPA-43 wersja 06 z dnia 02-01-2026 r.","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","parameters_zh":[{"name":"Na","range":"(30,0 – 10000) mg/kg"},{"name":"K","range":"(120 – 10000) mg/kg"},{"name":"Na2O","range":"(0,004 – 1,00) %"},{"name":"K2O","range":"(0,015 – 1,00) %"},{"name":"Fe2O3","range":"(0,020 – 1,00) %"},{"name":"Fe","range":"(0,013 – 0,70) %"},{"name":"Al2O3","range":"(0,020 – 1,00) %"},{"name":"Al.","range":"(0,010 – 0,52) %"},{"name":"MgO","range":"(0,090 – 5,00) %"},{"name":"Mg","range":"(0,054 – 3,01) %"}],"test_object_zh":"化工产品：石灰石，含钙质与碳酸盐吸收剂"},{"_id":"6a837a57af14b9c0e7b1fddc","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Wyroby chemiczne: kamień wapienny, w tym sorbenty wapniowe i węglanowe","methodology":"Zawartość krzemionki i części nierozpuszczalnych","parameters":[{"name":"Zakres","range":"(0,10 – 10,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość krzemionki i części nierozpuszczalnych\nZakres (0,10 – 10,0) %\nMetoda wagowa","reference":"IB-DPA-43 wersja 06 z dnia 02-01-2026 r.","norm_bases":["IB-DPA-43 wersja 06 z dnia 02-01-2026 r."],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby chemiczne: kamień wapienny, w tym sorbenty wapniowe i węglanowe Zawartość krzemionki i części nierozpuszczalnych\nZakres (0,10 – 10,0) %\nMetoda wagowa IB-DPA-43 wersja 06 z dnia 02-01-2026 r. Wyroby chemiczne: kamien wapienny, w tym sorbenty wapniowe i weglanowe Zawartosc krzemionki i czesci nierozpuszczalnych\nZakres (0,10 – 10,0) %\nMetoda wagowa IB-DPA-43 wersja 06 z dnia 02-01-2026 r.","categories":["other"],"row_index":143,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Silica and insoluble matter content","parameters_en":[{"name":"Range","range":"(0,10 – 10,0) %"}],"search_en":"Chemical products: limestone, including calcium and carbonate sorbents Silica and insoluble matter content Gravimetric method Range IB-DPA-43 wersja 06 z dnia 02-01-2026 r.","technique_en":"Gravimetric method","test_object_en":"Chemical products: limestone, including calcium and carbonate sorbents","parameters_zh":[{"name":"范围","range":"(0,10 – 10,0) %"}],"search_zh":"化工产品：石灰石，含钙质与碳酸盐吸收剂 重量法 范围 IB-DPA-43 wersja 06 z dnia 02-01-2026 r.","technique_zh":"重量法","test_object_zh":"化工产品：石灰石，含钙质与碳酸盐吸收剂"},{"_id":"6a837a57af14b9c0e7b1fddd","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Wyroby chemiczne: kamień wapienny, w tym sorbenty wapniowe i węglanowe","methodology":"Zawartość węgla całkowitego","parameters":[{"name":"Zakres","range":"(1,30 – 12,00)%"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość węgla całkowitego\nZakres (1,30 – 12,00)%\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"IB-DPA-44 wersja 06 z dnia 02-01-2026 r.","norm_bases":["IB-DPA-44 wersja 06 z dnia 02-01-2026 r."],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby chemiczne: kamień wapienny, w tym sorbenty wapniowe i węglanowe Zawartość węgla całkowitego\nZakres (1,30 – 12,00)%\nMetoda wysokotemperaturowego spalania z detekcją IR IB-DPA-44 wersja 06 z dnia 02-01-2026 r. Wyroby chemiczne: kamien wapienny, w tym sorbenty wapniowe i weglanowe Zawartosc wegla calkowitego\nZakres (1,30 – 12,00)%\nMetoda wysokotemperaturowego spalania z detekcja IR IB-DPA-44 wersja 06 z dnia 02-01-2026 r.","categories":["other"],"row_index":144,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total carbon content","parameters_en":[{"name":"Range","range":"(1,30 – 12,00)%"}],"search_en":"Chemical products: limestone, including calcium and carbonate sorbents Total carbon content High-temperature combustion with IR detection Range IB-DPA-44 wersja 06 z dnia 02-01-2026 r.","technique_en":"High-temperature combustion with IR detection","test_object_en":"Chemical products: limestone, including calcium and carbonate sorbents","methodology_zh":"总碳含量","parameters_zh":[{"name":"范围","range":"(1,30 – 12,00)%"}],"search_zh":"化工产品：石灰石，含钙质与碳酸盐吸收剂 总碳含量 高温燃烧红外检测法 范围 IB-DPA-44 wersja 06 z dnia 02-01-2026 r.","technique_zh":"高温燃烧红外检测法","test_object_zh":"化工产品：石灰石，含钙质与碳酸盐吸收剂"},{"_id":"6a837a57af14b9c0e7b1fdde","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Wyroby chemiczne: kamień wapienny, w tym sorbenty wapniowe i węglanowe","methodology":"Zawartość rtęci Hg","parameters":[{"name":"Zakres","range":"(0,0030 – 0,020) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","techniques":["Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji"],"computed":[],"activity":"Zawartość rtęci Hg\nZakres (0,0030 – 0,020) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","reference":"IB-DPA-09 wersja 04 z dnia 02-01-2026 r.","norm_bases":["IB-DPA-09 wersja 04 z dnia 02-01-2026 r."],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby chemiczne: kamień wapienny, w tym sorbenty wapniowe i węglanowe Zawartość rtęci Hg\nZakres (0,0030 – 0,020) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji IB-DPA-09 wersja 04 z dnia 02-01-2026 r. Wyroby chemiczne: kamien wapienny, w tym sorbenty wapniowe i weglanowe Zawartosc rteci Hg\nZakres (0,0030 – 0,020) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z technika amalgamacji IB-DPA-09 wersja 04 z dnia 02-01-2026 r.","categories":["other"],"row_index":145,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury Hg content","parameters_en":[{"name":"Range","range":"(0,0030 – 0,020) mg/kg"}],"search_en":"Chemical products: limestone, including calcium and carbonate sorbents Mercury Hg content Atomic absorption spectrometry with amalgamation technique Range IB-DPA-09 wersja 04 z dnia 02-01-2026 r.","technique_en":"Atomic absorption spectrometry with amalgamation technique","test_object_en":"Chemical products: limestone, including calcium and carbonate sorbents","parameters_zh":[{"name":"范围","range":"(0,0030 – 0,020) mg/kg"}],"search_zh":"化工产品：石灰石，含钙质与碳酸盐吸收剂 原子吸收光谱法（汞齐化技术） 范围 IB-DPA-09 wersja 04 z dnia 02-01-2026 r.","technique_zh":"原子吸收光谱法（汞齐化技术）","test_object_zh":"化工产品：石灰石，含钙质与碳酸盐吸收剂"},{"_id":"6a837a57af14b9c0e7b1fddf","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-G-04502:2014-11 pkt 5.3.1.2; 5.3.1.3; 5.3.1.4; 5.3.3; 5.3.4; 5.3.6","norm_bases":["PN-G-04502:2014-11 pkt 5.3.1.2; 5.3.1.3; 5.3.1.4; 5.3.3; 5.3.4; 5.3.6"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Pobieranie próbek do badań chemicznych i fizycznych PN-G-04502:2014-11 pkt 5.3.1.2; 5.3.1.3; 5.3.1.4; 5.3.3; 5.3.4; 5.3.6 Paliwa stale: wegiel kamienny Pobieranie probek do badan chemicznych i fizycznych PN-G-04502:2014-11 pkt 5.3.1.2; 5.3.1.3; 5.3.1.4; 5.3.3; 5.3.4; 5.3.6","categories":["petro"],"row_index":146,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Solid fuels: hard coal Sampling for chemical and physical testing PN-G-04502:2014-11 pkt 5.3.1.2; 5.3.1.3; 5.3.1.4; 5.3.3; 5.3.4; 5.3.6","test_object_en":"Solid fuels: hard coal","methodology_zh":"化学与物理检测用样品采集","search_zh":"固体燃料：烟煤 化学与物理检测用样品采集 PN-G-04502:2014-11 pkt 5.3.1.2; 5.3.1.3; 5.3.1.4; 5.3.3; 5.3.4; 5.3.6","test_object_zh":"固体燃料：烟煤"},{"_id":"6a837a57af14b9c0e7b1fde0","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wilgoci pierwszego stopnia (wilgoci przemijającej)","parameters":[{"name":"Zakres","range":"(1,0 – 39,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci pierwszego stopnia (wilgoci przemijającej)\nZakres (1,0 – 39,0) %\nMetoda wagowa","reference":"PN-ISO 589:2006 | PN-G-04611:2020-06","norm_bases":["PN-ISO 589:2006","PN-G-04611:2020-06"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci pierwszego stopnia (wilgoci przemijającej)\nZakres (1,0 – 39,0) %\nMetoda wagowa PN-ISO 589:2006 | PN-G-04611:2020-06 Paliwa stale: wegiel kamienny Zawartosc wilgoci pierwszego stopnia (wilgoci przemijajacej)\nZakres (1,0 – 39,0) %\nMetoda wagowa PN-ISO 589:2006 | PN-G-04611:2020-06","categories":["petro"],"row_index":147,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"First-stage moisture content (free moisture)","parameters_en":[{"name":"Range","range":"(1,0 – 39,0) %"}],"search_en":"Solid fuels: hard coal First-stage moisture content (free moisture) Gravimetric method Range PN-ISO 589:2006 | PN-G-04611:2020-06","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","parameters_zh":[{"name":"范围","range":"(1,0 – 39,0) %"}],"search_zh":"固体燃料：烟煤 第一阶段水分（外在水分）含量 重量法 范围 PN-ISO 589:2006 | PN-G-04611:2020-06","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤","methodology_zh":"第一阶段水分（外在水分）含量"},{"_id":"6a837a57af14b9c0e7b1fde1","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wilgoci w próbce analitycznej","parameters":[{"name":"Zakres","range":"(0,4 – 13,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (0,4 – 13,0) %\nMetoda wagowa","reference":"PN-G-04611:2020-06","norm_bases":["PN-G-04611:2020-06"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci w próbce analitycznej\nZakres (0,4 – 13,0) %\nMetoda wagowa PN-G-04611:2020-06 Paliwa stale: wegiel kamienny Zawartosc wilgoci w probce analitycznej\nZakres (0,4 – 13,0) %\nMetoda wagowa PN-G-04611:2020-06","categories":["petro"],"row_index":148,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Moisture content in the analytical sample","parameters_en":[{"name":"Range","range":"(0,4 – 13,0) %"}],"search_en":"Solid fuels: hard coal Moisture content in the analytical sample Gravimetric method Range PN-G-04611:2020-06","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(0,4 – 13,0) %"}],"search_zh":"固体燃料：烟煤 分析样品水分含量 重量法 范围 PN-G-04611:2020-06","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a837a57af14b9c0e7b1fde2","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wilgoci w próbce analitycznej","parameters":[{"name":"Zakres","range":"(0,40 – 15,00) %"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (0,40 – 15,00) %\nMetoda termograwimetryczna (TGA)","reference":"PN-G-04560:1998","norm_bases":["PN-G-04560:1998"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci w próbce analitycznej\nZakres (0,40 – 15,00) %\nMetoda termograwimetryczna (TGA) PN-G-04560:1998 Paliwa stale: wegiel kamienny Zawartosc wilgoci w probce analitycznej\nZakres (0,40 – 15,00) %\nMetoda termograwimetryczna (TGA) PN-G-04560:1998","categories":["petro"],"row_index":149,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Moisture content in the analytical sample","parameters_en":[{"name":"Range","range":"(0,40 – 15,00) %"}],"search_en":"Solid fuels: hard coal Moisture content in the analytical sample Thermogravimetric method (TGA) Range PN-G-04560:1998","technique_en":"Thermogravimetric method (TGA)","test_object_en":"Solid fuels: hard coal","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(0,40 – 15,00) %"}],"search_zh":"固体燃料：烟煤 分析样品水分含量 热重法（TGA） 范围 PN-G-04560:1998","technique_zh":"热重法（TGA）","test_object_zh":"固体燃料：烟煤"},{"_id":"6a837a57af14b9c0e7b1fde3","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wilgoci całkowitej (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość wilgoci całkowitej (z obliczeń)","reference":"PN-ISO 589:2006, Metoda A2 | PN-G-04611:2020-06","norm_bases":["PN-ISO 589:2006, Metoda A2","PN-G-04611:2020-06"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci całkowitej (z obliczeń) PN-ISO 589:2006, Metoda A2 | PN-G-04611:2020-06 Paliwa stale: wegiel kamienny Zawartosc wilgoci calkowitej (z obliczen) PN-ISO 589:2006, Metoda A2 | PN-G-04611:2020-06","categories":["petro"],"row_index":150,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total moisture content (calculated)","search_en":"Solid fuels: hard coal Total moisture content (calculated) PN-ISO 589:2006, Metoda A2 | PN-G-04611:2020-06","test_object_en":"Solid fuels: hard coal","search_zh":"固体燃料：烟煤 全水分含量（计算值） PN-ISO 589:2006, Metoda A2 | PN-G-04611:2020-06","test_object_zh":"固体燃料：烟煤","methodology_zh":"全水分含量（计算值）"},{"_id":"6a837a57af14b9c0e7b1fde4","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wilgoci całkowitej","parameters":[{"name":"Zakres","range":"(2,0 – 45,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci całkowitej\nZakres (2,0 – 45,0) %\nMetoda wagowa","reference":"PN-G-04611:2020-06","norm_bases":["PN-G-04611:2020-06"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci całkowitej\nZakres (2,0 – 45,0) %\nMetoda wagowa PN-G-04611:2020-06 Paliwa stale: wegiel kamienny Zawartosc wilgoci calkowitej\nZakres (2,0 – 45,0) %\nMetoda wagowa PN-G-04611:2020-06","categories":["petro"],"row_index":151,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total moisture content","parameters_en":[{"name":"Range","range":"(2,0 – 45,0) %"}],"search_en":"Solid fuels: hard coal Total moisture content Gravimetric method Range PN-G-04611:2020-06","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","methodology_zh":"全水分含量","parameters_zh":[{"name":"范围","range":"(2,0 – 45,0) %"}],"search_zh":"固体燃料：烟煤 全水分含量 重量法 范围 PN-G-04611:2020-06","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a837a57af14b9c0e7b1fde5","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wilgoci całkowitej","parameters":[{"name":"Zakres","range":"(2,0 – 45,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci całkowitej\nZakres (2,0 – 45,0) %\nMetoda wagowa","reference":"PN-ISO 589:2006, Metoda B2","norm_bases":["PN-ISO 589:2006, Metoda B2"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci całkowitej\nZakres (2,0 – 45,0) %\nMetoda wagowa PN-ISO 589:2006, Metoda B2 Paliwa stale: wegiel kamienny Zawartosc wilgoci calkowitej\nZakres (2,0 – 45,0) %\nMetoda wagowa PN-ISO 589:2006, Metoda B2","categories":["petro"],"row_index":152,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total moisture content","parameters_en":[{"name":"Range","range":"(2,0 – 45,0) %"}],"search_en":"Solid fuels: hard coal Total moisture content Gravimetric method Range PN-ISO 589:2006, Metoda B2","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","methodology_zh":"全水分含量","parameters_zh":[{"name":"范围","range":"(2,0 – 45,0) %"}],"search_zh":"固体燃料：烟煤 全水分含量 重量法 范围 PN-ISO 589:2006, Metoda B2","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a837a57af14b9c0e7b1fde6","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wilgoci drugiego stopnia (wilgoć pozostała w próbce)","parameters":[{"name":"Zakres","range":"(0,4 – 15,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci drugiego stopnia (wilgoć pozostała w próbce)\nZakres (0,4 – 15,0) %\nMetoda wagowa","reference":"PN-ISO 589:2006, Metoda A2","norm_bases":["PN-ISO 589:2006, Metoda A2"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci drugiego stopnia (wilgoć pozostała w próbce)\nZakres (0,4 – 15,0) %\nMetoda wagowa PN-ISO 589:2006, Metoda A2 Paliwa stale: wegiel kamienny Zawartosc wilgoci drugiego stopnia (wilgoc pozostala w probce)\nZakres (0,4 – 15,0) %\nMetoda wagowa PN-ISO 589:2006, Metoda A2","categories":["petro"],"row_index":153,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Second-stage moisture content (residual moisture in the sample)","parameters_en":[{"name":"Range","range":"(0,4 – 15,0) %"}],"search_en":"Solid fuels: hard coal Second-stage moisture content (residual moisture in the sample) Gravimetric method Range PN-ISO 589:2006, Metoda A2","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","parameters_zh":[{"name":"范围","range":"(0,4 – 15,0) %"}],"search_zh":"固体燃料：烟煤 第二阶段水分（样品残余水分）含量 重量法 范围 PN-ISO 589:2006, Metoda A2","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤","methodology_zh":"第二阶段水分（样品残余水分）含量"},{"_id":"6a837a57af14b9c0e7b1fde7","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość popiołu","parameters":[{"name":"Zakres","range":"(2,0 – 75,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość popiołu\nZakres (2,0 – 75,0) %\nMetoda wagowa","reference":"PN-ISO 1171:2002","norm_bases":["PN-ISO 1171:2002"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość popiołu\nZakres (2,0 – 75,0) %\nMetoda wagowa PN-ISO 1171:2002 Paliwa stale: wegiel kamienny Zawartosc popiolu\nZakres (2,0 – 75,0) %\nMetoda wagowa PN-ISO 1171:2002","categories":["petro"],"row_index":154,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ash content","parameters_en":[{"name":"Range","range":"(2,0 – 75,0) %"}],"search_en":"Solid fuels: hard coal Ash content Gravimetric method Range PN-ISO 1171:2002","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(2,0 – 75,0) %"}],"search_zh":"固体燃料：烟煤 灰分含量 重量法 范围 PN-ISO 1171:2002","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a837a57af14b9c0e7b1fde8","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość popiołu","parameters":[{"name":"Zakres","range":"(2,00 – 75,00) %"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)"],"computed":[],"activity":"Zawartość popiołu\nZakres (2,00 – 75,00) %\nMetoda termograwimetryczna (TGA)","reference":"PN-G-04560:1998","norm_bases":["PN-G-04560:1998"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość popiołu\nZakres (2,00 – 75,00) %\nMetoda termograwimetryczna (TGA) PN-G-04560:1998 Paliwa stale: wegiel kamienny Zawartosc popiolu\nZakres (2,00 – 75,00) %\nMetoda termograwimetryczna (TGA) PN-G-04560:1998","categories":["petro"],"row_index":155,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ash content","parameters_en":[{"name":"Range","range":"(2,00 – 75,00) %"}],"search_en":"Solid fuels: hard coal Ash content Thermogravimetric method (TGA) Range PN-G-04560:1998","technique_en":"Thermogravimetric method (TGA)","test_object_en":"Solid fuels: hard coal","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(2,00 – 75,00) %"}],"search_zh":"固体燃料：烟煤 灰分含量 热重法（TGA） 范围 PN-G-04560:1998","technique_zh":"热重法（TGA）","test_object_zh":"固体燃料：烟煤"},{"_id":"6a837a57af14b9c0e7b1fde9","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość siarki całkowitej","parameters":[{"name":"Zakres","range":"(0,10 – 3,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość siarki całkowitej\nZakres (0,10 – 3,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04584:2001 | ISO 19579:2006","norm_bases":["PN-G-04584:2001","ISO 19579:2006"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość siarki całkowitej\nZakres (0,10 – 3,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04584:2001 | ISO 19579:2006 Paliwa stale: wegiel kamienny Zawartosc siarki calkowitej\nZakres (0,10 – 3,00) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04584:2001 | ISO 19579:2006","categories":["petro"],"row_index":156,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total sulfur content","parameters_en":[{"name":"Range","range":"(0,10 – 3,00) %"}],"search_en":"Solid fuels: hard coal Total sulfur content High-temperature combustion with IR detection Range PN-G-04584:2001 | ISO 19579:2006","technique_en":"High-temperature combustion with IR detection","test_object_en":"Solid fuels: hard coal","methodology_zh":"全硫含量","parameters_zh":[{"name":"范围","range":"(0,10 – 3,00) %"}],"search_zh":"固体燃料：烟煤 全硫含量 高温燃烧红外检测法 范围 PN-G-04584:2001 | ISO 19579:2006","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a837a57af14b9c0e7b1fdea","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Ciepło spalania","parameters":[{"name":"Zakres","range":"(6000– 34000) kJ/kg"},{"name":"Wartość opałowa (z obliczeń)"}],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna"],"computed":[],"activity":"Ciepło spalania\nZakres:\nZakres (6000– 34000) kJ/kg\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna","reference":"PN-81/G-04513 | PN-ISO 1928:2020-05","norm_bases":["PN-81/G-04513","PN-ISO 1928:2020-05"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Ciepło spalania\nZakres:\nZakres (6000– 34000) kJ/kg\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna PN-81/G-04513 | PN-ISO 1928:2020-05 Paliwa stale: wegiel kamienny Cieplo spalania\nZakres:\nZakres (6000– 34000) kJ/kg\nWartosc opalowa (z obliczen)\nMetoda kalorymetryczna PN-81/G-04513 | PN-ISO 1928:2020-05","categories":["petro"],"row_index":157,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gross calorific value","parameters_en":[{"name":"Range","range":"(6000– 34000) kJ/kg"},{"name":"Net calorific value (calculated)"}],"search_en":"Solid fuels: hard coal Gross calorific value Calorimetric method Range Net calorific value (calculated) PN-81/G-04513 | PN-ISO 1928:2020-05","technique_en":"Calorimetric method","test_object_en":"Solid fuels: hard coal","methodology_zh":"高位发热量","parameters_zh":[{"name":"范围","range":"(6000– 34000) kJ/kg"},{"name":"低位发热量（计算值）"}],"search_zh":"固体燃料：烟煤 高位发热量 量热法 范围 低位发热量（计算值） PN-81/G-04513 | PN-ISO 1928:2020-05","technique_zh":"量热法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a837a57af14b9c0e7b1fdeb","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość węgla całkowitego","parameters":[{"name":"Zakres","range":"(15,0 – 85,0) %"},{"name":"Zawartość wodoru"},{"name":"Zakres","range":"(1,30 – 5,50) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość węgla całkowitego\nZakres:\nZakres (15,0 – 85,0) %\nZawartość wodoru\nZakres (1,30 – 5,50) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"ISO 29541:2025-02","norm_bases":["ISO 29541:2025-02"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość węgla całkowitego\nZakres:\nZakres (15,0 – 85,0) %\nZawartość wodoru\nZakres (1,30 – 5,50) %\nMetoda wysokotemperaturowego spalania z detekcją IR ISO 29541:2025-02 Paliwa stale: wegiel kamienny Zawartosc wegla calkowitego\nZakres:\nZakres (15,0 – 85,0) %\nZawartosc wodoru\nZakres (1,30 – 5,50) %\nMetoda wysokotemperaturowego spalania z detekcja IR ISO 29541:2025-02","categories":["petro"],"row_index":158,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total carbon content","parameters_en":[{"name":"Range","range":"(15,0 – 85,0) %"},{"name":"Hydrogen content"},{"name":"Range","range":"(1,30 – 5,50) %"}],"search_en":"Solid fuels: hard coal Total carbon content High-temperature combustion with IR detection Range Hydrogen content Range ISO 29541:2025-02","technique_en":"High-temperature combustion with IR detection","test_object_en":"Solid fuels: hard coal","methodology_zh":"总碳含量","parameters_zh":[{"name":"范围","range":"(15,0 – 85,0) %"},{"name":"氢含量"},{"name":"范围","range":"(1,30 – 5,50) %"}],"search_zh":"固体燃料：烟煤 总碳含量 高温燃烧红外检测法 范围 氢含量 范围 ISO 29541:2025-02","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a837a57af14b9c0e7b1fdec","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość azotu","parameters":[{"name":"Zakres","range":"(0,20 – 1,90) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją TC","techniques":["Metoda wysokotemperaturowego spalania z detekcją TC"],"computed":[],"activity":"Zawartość azotu\nZakres (0,20 – 1,90) %\nMetoda wysokotemperaturowego spalania z detekcją TC","reference":"ISO 29541:2025-02","norm_bases":["ISO 29541:2025-02"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość azotu\nZakres (0,20 – 1,90) %\nMetoda wysokotemperaturowego spalania z detekcją TC ISO 29541:2025-02 Paliwa stale: wegiel kamienny Zawartosc azotu\nZakres (0,20 – 1,90) %\nMetoda wysokotemperaturowego spalania z detekcja TC ISO 29541:2025-02","categories":["petro"],"row_index":159,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrogen content","parameters_en":[{"name":"Range","range":"(0,20 – 1,90) %"}],"search_en":"Solid fuels: hard coal Nitrogen content High-temperature combustion with TC detection Range ISO 29541:2025-02","technique_en":"High-temperature combustion with TC detection","test_object_en":"Solid fuels: hard coal","methodology_zh":"氮含量","parameters_zh":[{"name":"范围","range":"(0,20 – 1,90) %"}],"search_zh":"固体燃料：烟煤 氮含量 高温燃烧总碳检测法 范围 ISO 29541:2025-02","test_object_zh":"固体燃料：烟煤","technique_zh":"高温燃烧总碳检测法"},{"_id":"6a837a57af14b9c0e7b1fded","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość węgla całkowitego","parameters":[{"name":"Zakres","range":"(15,0 – 85,0) %"},{"name":"Zawartość wodoru"},{"name":"Zakres","range":"(1,30 – 5,50) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość węgla całkowitego\nZakres:\nZakres (15,0 – 85,0) %\nZawartość wodoru\nZakres (1,30 – 5,50) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04571:1998","norm_bases":["PN-G-04571:1998"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość węgla całkowitego\nZakres:\nZakres (15,0 – 85,0) %\nZawartość wodoru\nZakres (1,30 – 5,50) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04571:1998 Paliwa stale: wegiel kamienny Zawartosc wegla calkowitego\nZakres:\nZakres (15,0 – 85,0) %\nZawartosc wodoru\nZakres (1,30 – 5,50) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04571:1998","categories":["petro"],"row_index":160,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total carbon content","parameters_en":[{"name":"Range","range":"(15,0 – 85,0) %"},{"name":"Hydrogen content"},{"name":"Range","range":"(1,30 – 5,50) %"}],"search_en":"Solid fuels: hard coal Total carbon content High-temperature combustion with IR detection Range Hydrogen content Range PN-G-04571:1998","technique_en":"High-temperature combustion with IR detection","test_object_en":"Solid fuels: hard coal","methodology_zh":"总碳含量","parameters_zh":[{"name":"范围","range":"(15,0 – 85,0) %"},{"name":"氢含量"},{"name":"范围","range":"(1,30 – 5,50) %"}],"search_zh":"固体燃料：烟煤 总碳含量 高温燃烧红外检测法 范围 氢含量 范围 PN-G-04571:1998","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a837a57af14b9c0e7b1fdee","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość azotu","parameters":[{"name":"Zakres","range":"(0,20 – 1,50) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją TC","techniques":["Metoda wysokotemperaturowego spalania z detekcją TC"],"computed":[],"activity":"Zawartość azotu\nZakres (0,20 – 1,50) %\nMetoda wysokotemperaturowego spalania z detekcją TC","reference":"PN-G-04571:1998","norm_bases":["PN-G-04571:1998"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość azotu\nZakres (0,20 – 1,50) %\nMetoda wysokotemperaturowego spalania z detekcją TC PN-G-04571:1998 Paliwa stale: wegiel kamienny Zawartosc azotu\nZakres (0,20 – 1,50) %\nMetoda wysokotemperaturowego spalania z detekcja TC PN-G-04571:1998","categories":["petro"],"row_index":161,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrogen content","parameters_en":[{"name":"Range","range":"(0,20 – 1,50) %"}],"search_en":"Solid fuels: hard coal Nitrogen content High-temperature combustion with TC detection Range PN-G-04571:1998","technique_en":"High-temperature combustion with TC detection","test_object_en":"Solid fuels: hard coal","methodology_zh":"氮含量","parameters_zh":[{"name":"范围","range":"(0,20 – 1,50) %"}],"search_zh":"固体燃料：烟煤 氮含量 高温燃烧总碳检测法 范围 PN-G-04571:1998","test_object_zh":"固体燃料：烟煤","technique_zh":"高温燃烧总碳检测法"},{"_id":"6a837a57af14b9c0e7b1fdef","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość części lotnych","parameters":[{"name":"Zakres","range":"(10,00 – 40,00) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość części lotnych\nZakres (10,00 – 40,00) %\nMetoda wagowa","reference":"PN-G-04516:1998","norm_bases":["PN-G-04516:1998"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość części lotnych\nZakres (10,00 – 40,00) %\nMetoda wagowa PN-G-04516:1998 Paliwa stale: wegiel kamienny Zawartosc czesci lotnych\nZakres (10,00 – 40,00) %\nMetoda wagowa PN-G-04516:1998","categories":["petro"],"row_index":162,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Volatile matter content","parameters_en":[{"name":"Range","range":"(10,00 – 40,00) %"}],"search_en":"Solid fuels: hard coal Volatile matter content Gravimetric method Range PN-G-04516:1998","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","parameters_zh":[{"name":"范围","range":"(10,00 – 40,00) %"}],"search_zh":"固体燃料：烟煤 挥发分含量 重量法 范围 PN-G-04516:1998","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤","methodology_zh":"挥发分含量"},{"_id":"6a837a57af14b9c0e7b1fdf0","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Fixed carbon (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Fixed carbon (z obliczeń)","reference":"PN-G-04516:1998","norm_bases":["PN-G-04516:1998"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Fixed carbon (z obliczeń) PN-G-04516:1998 Paliwa stale: wegiel kamienny Fixed carbon (z obliczen) PN-G-04516:1998","categories":["petro"],"row_index":163,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fixed carbon (calculated)","search_en":"Solid fuels: hard coal Fixed carbon (calculated) PN-G-04516:1998","test_object_en":"Solid fuels: hard coal","search_zh":"固体燃料：烟煤 固定碳（由计算得出） PN-G-04516:1998","test_object_zh":"固体燃料：烟煤","methodology_zh":"固定碳（由计算得出）"},{"_id":"6a837a57af14b9c0e7b1fdf1","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-EN ISO 18135:2017-06 z wyłączeniem pkt 12.4","norm_bases":["PN-EN ISO 18135:2017-06 z wyłączeniem pkt 12.4"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Pobieranie próbek do badań chemicznych i fizycznych PN-EN ISO 18135:2017-06 z wyłączeniem pkt 12.4 Paliwa stale: biomasa stala – biopaliwo stale Pobieranie probek do badan chemicznych i fizycznych PN-EN ISO 18135:2017-06 z wylaczeniem pkt 12.4","categories":["petro"],"row_index":164,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Solid fuels: solid biomass – solid biofuel Sampling for chemical and physical testing PN-EN ISO 18135:2017-06 z wyłączeniem pkt 12.4","test_object_en":"Solid fuels: solid biomass – solid biofuel","methodology_zh":"化学与物理检测用样品采集","search_zh":"固体燃料：固体生物质 – 固体生物燃料 化学与物理检测用样品采集 PN-EN ISO 18135:2017-06 z wyłączeniem pkt 12.4","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料"},{"_id":"6a837a57af14b9c0e7b1fdf2","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","methodology":"Zawartość wilgoci całkowitej","parameters":[{"name":"Zakres","range":"(4,0 – 70,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci całkowitej\nZakres (4,0 – 70,0) %\nMetoda wagowa","reference":"PN-EN ISO 18134-1:2023-02","norm_bases":["PN-EN ISO 18134-1:2023-02"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Zawartość wilgoci całkowitej\nZakres (4,0 – 70,0) %\nMetoda wagowa PN-EN ISO 18134-1:2023-02 Paliwa stale: biomasa stala – biopaliwo stale Zawartosc wilgoci calkowitej\nZakres (4,0 – 70,0) %\nMetoda wagowa PN-EN ISO 18134-1:2023-02","categories":["petro"],"row_index":165,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total moisture content","parameters_en":[{"name":"Range","range":"(4,0 – 70,0) %"}],"search_en":"Solid fuels: solid biomass – solid biofuel Total moisture content Gravimetric method Range PN-EN ISO 18134-1:2023-02","technique_en":"Gravimetric method","test_object_en":"Solid fuels: solid biomass – solid biofuel","methodology_zh":"全水分含量","parameters_zh":[{"name":"范围","range":"(4,0 – 70,0) %"}],"search_zh":"固体燃料：固体生物质 – 固体生物燃料 全水分含量 重量法 范围 PN-EN ISO 18134-1:2023-02","technique_zh":"重量法","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料"},{"_id":"6a837a57af14b9c0e7b1fdf3","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","methodology":"Zawartość wilgoci całkowitej","parameters":[{"name":"Zakres","range":"(4,0 – 70,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci całkowitej\nZakres (4,0 – 70,0) %\nMetoda wagowa","reference":"PN-EN ISO 18134-2:2024-10","norm_bases":["PN-EN ISO 18134-2:2024-10"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Zawartość wilgoci całkowitej\nZakres (4,0 – 70,0) %\nMetoda wagowa PN-EN ISO 18134-2:2024-10 Paliwa stale: biomasa stala – biopaliwo stale Zawartosc wilgoci calkowitej\nZakres (4,0 – 70,0) %\nMetoda wagowa PN-EN ISO 18134-2:2024-10","categories":["petro"],"row_index":166,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total moisture content","parameters_en":[{"name":"Range","range":"(4,0 – 70,0) %"}],"search_en":"Solid fuels: solid biomass – solid biofuel Total moisture content Gravimetric method Range PN-EN ISO 18134-2:2024-10","technique_en":"Gravimetric method","test_object_en":"Solid fuels: solid biomass – solid biofuel","methodology_zh":"全水分含量","parameters_zh":[{"name":"范围","range":"(4,0 – 70,0) %"}],"search_zh":"固体燃料：固体生物质 – 固体生物燃料 全水分含量 重量法 范围 PN-EN ISO 18134-2:2024-10","technique_zh":"重量法","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料"},{"_id":"6a837a57af14b9c0e7b1fdf4","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","methodology":"Zawartość wilgoci w próbce analitycznej","parameters":[{"name":"Zakres","range":"(0,5 – 15,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (0,5 – 15,0) %\nMetoda wagowa","reference":"PN-EN ISO 18134-3:2023-12","norm_bases":["PN-EN ISO 18134-3:2023-12"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Zawartość wilgoci w próbce analitycznej\nZakres (0,5 – 15,0) %\nMetoda wagowa PN-EN ISO 18134-3:2023-12 Paliwa stale: biomasa stala – biopaliwo stale Zawartosc wilgoci w probce analitycznej\nZakres (0,5 – 15,0) %\nMetoda wagowa PN-EN ISO 18134-3:2023-12","categories":["petro"],"row_index":167,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Moisture content in the analytical sample","parameters_en":[{"name":"Range","range":"(0,5 – 15,0) %"}],"search_en":"Solid fuels: solid biomass – solid biofuel Moisture content in the analytical sample Gravimetric method Range PN-EN ISO 18134-3:2023-12","technique_en":"Gravimetric method","test_object_en":"Solid fuels: solid biomass – solid biofuel","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(0,5 – 15,0) %"}],"search_zh":"固体燃料：固体生物质 – 固体生物燃料 分析样品水分含量 重量法 范围 PN-EN ISO 18134-3:2023-12","technique_zh":"重量法","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料"},{"_id":"6a837a57af14b9c0e7b1fdf5","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","methodology":"Zawartość wilgoci w próbce analitycznej","parameters":[{"name":"Zakres","range":"(0,50 – 15,00) %"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (0,50 – 15,00) %\nMetoda termograwimetryczna (TGA)","reference":"PN-EN ISO 18134-3:2023-12","norm_bases":["PN-EN ISO 18134-3:2023-12"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Zawartość wilgoci w próbce analitycznej\nZakres (0,50 – 15,00) %\nMetoda termograwimetryczna (TGA) PN-EN ISO 18134-3:2023-12 Paliwa stale: biomasa stala – biopaliwo stale Zawartosc wilgoci w probce analitycznej\nZakres (0,50 – 15,00) %\nMetoda termograwimetryczna (TGA) PN-EN ISO 18134-3:2023-12","categories":["petro"],"row_index":168,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Moisture content in the analytical sample","parameters_en":[{"name":"Range","range":"(0,50 – 15,00) %"}],"search_en":"Solid fuels: solid biomass – solid biofuel Moisture content in the analytical sample Thermogravimetric method (TGA) Range PN-EN ISO 18134-3:2023-12","technique_en":"Thermogravimetric method (TGA)","test_object_en":"Solid fuels: solid biomass – solid biofuel","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(0,50 – 15,00) %"}],"search_zh":"固体燃料：固体生物质 – 固体生物燃料 分析样品水分含量 热重法（TGA） 范围 PN-EN ISO 18134-3:2023-12","technique_zh":"热重法（TGA）","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料"},{"_id":"6a837a57af14b9c0e7b1fdf6","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","methodology":"Zawartość popiołu w próbce analitycznej","parameters":[{"name":"Zakres","range":"(0,3 – 90,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość popiołu w próbce analitycznej\nZakres (0,3 – 90,0) %\nMetoda wagowa","reference":"PN-EN ISO 18122:2023-05","norm_bases":["PN-EN ISO 18122:2023-05"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Zawartość popiołu w próbce analitycznej\nZakres (0,3 – 90,0) %\nMetoda wagowa PN-EN ISO 18122:2023-05 Paliwa stale: biomasa stala – biopaliwo stale Zawartosc popiolu w probce analitycznej\nZakres (0,3 – 90,0) %\nMetoda wagowa PN-EN ISO 18122:2023-05","categories":["petro"],"row_index":169,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ash content in the analytical sample","parameters_en":[{"name":"Range","range":"(0,3 – 90,0) %"}],"search_en":"Solid fuels: solid biomass – solid biofuel Ash content in the analytical sample Gravimetric method Range PN-EN ISO 18122:2023-05","technique_en":"Gravimetric method","test_object_en":"Solid fuels: solid biomass – solid biofuel","parameters_zh":[{"name":"范围","range":"(0,3 – 90,0) %"}],"search_zh":"固体燃料：固体生物质 – 固体生物燃料 重量法 范围 PN-EN ISO 18122:2023-05","technique_zh":"重量法","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料"},{"_id":"6a837a57af14b9c0e7b1fdf7","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","methodology":"Zawartość popiołu w próbce analitycznej","parameters":[{"name":"Zakres","range":"(0,30 – 90,00) %"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)"],"computed":[],"activity":"Zawartość popiołu w próbce analitycznej\nZakres (0,30 – 90,00) %\nMetoda termograwimetryczna (TGA)","reference":"PN-EN ISO 18122:2023-05","norm_bases":["PN-EN ISO 18122:2023-05"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Zawartość popiołu w próbce analitycznej\nZakres (0,30 – 90,00) %\nMetoda termograwimetryczna (TGA) PN-EN ISO 18122:2023-05 Paliwa stale: biomasa stala – biopaliwo stale Zawartosc popiolu w probce analitycznej\nZakres (0,30 – 90,00) %\nMetoda termograwimetryczna (TGA) PN-EN ISO 18122:2023-05","categories":["petro"],"row_index":170,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ash content in the analytical sample","parameters_en":[{"name":"Range","range":"(0,30 – 90,00) %"}],"search_en":"Solid fuels: solid biomass – solid biofuel Ash content in the analytical sample Thermogravimetric method (TGA) Range PN-EN ISO 18122:2023-05","technique_en":"Thermogravimetric method (TGA)","test_object_en":"Solid fuels: solid biomass – solid biofuel","parameters_zh":[{"name":"范围","range":"(0,30 – 90,00) %"}],"search_zh":"固体燃料：固体生物质 – 固体生物燃料 热重法（TGA） 范围 PN-EN ISO 18122:2023-05","technique_zh":"热重法（TGA）","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料"},{"_id":"6a837a57af14b9c0e7b1fdf8","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","methodology":"Zawartość siarki całkowitej","parameters":[{"name":"Zakres","range":"(0,01 – 3,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość siarki całkowitej\nZakres (0,01 – 3,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN ISO 16994:2016-10","norm_bases":["PN-EN ISO 16994:2016-10"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Zawartość siarki całkowitej\nZakres (0,01 – 3,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN ISO 16994:2016-10 Paliwa stale: biomasa stala – biopaliwo stale Zawartosc siarki calkowitej\nZakres (0,01 – 3,00) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN ISO 16994:2016-10","categories":["petro"],"row_index":171,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total sulfur content","parameters_en":[{"name":"Range","range":"(0,01 – 3,00) %"}],"search_en":"Solid fuels: solid biomass – solid biofuel Total sulfur content High-temperature combustion with IR detection Range PN-EN ISO 16994:2016-10","technique_en":"High-temperature combustion with IR detection","test_object_en":"Solid fuels: solid biomass – solid biofuel","methodology_zh":"全硫含量","parameters_zh":[{"name":"范围","range":"(0,01 – 3,00) %"}],"search_zh":"固体燃料：固体生物质 – 固体生物燃料 全硫含量 高温燃烧红外检测法 范围 PN-EN ISO 16994:2016-10","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料"},{"_id":"6a837a57af14b9c0e7b1fdf9","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","methodology":"Ciepło spalania","parameters":[{"name":"Zakres","range":"(3500 − 26 000) kJ/kg"},{"name":"Wartość opałowa (z obliczeń)"}],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna"],"computed":[],"activity":"Ciepło spalania\nZakres:\nZakres (3500 − 26 000) kJ/kg\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna","reference":"PN-EN ISO 18125:2017-07","norm_bases":["PN-EN ISO 18125:2017-07"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Ciepło spalania\nZakres:\nZakres (3500 − 26 000) kJ/kg\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna PN-EN ISO 18125:2017-07 Paliwa stale: biomasa stala – biopaliwo stale Cieplo spalania\nZakres:\nZakres (3500 − 26 000) kJ/kg\nWartosc opalowa (z obliczen)\nMetoda kalorymetryczna PN-EN ISO 18125:2017-07","categories":["petro"],"row_index":172,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gross calorific value","parameters_en":[{"name":"Range","range":"(3500 − 26 000) kJ/kg"},{"name":"Net calorific value (calculated)"}],"search_en":"Solid fuels: solid biomass – solid biofuel Gross calorific value Calorimetric method Range Net calorific value (calculated) PN-EN ISO 18125:2017-07","technique_en":"Calorimetric method","test_object_en":"Solid fuels: solid biomass – solid biofuel","methodology_zh":"高位发热量","parameters_zh":[{"name":"范围","range":"(3500 − 26 000) kJ/kg"},{"name":"低位发热量（计算值）"}],"search_zh":"固体燃料：固体生物质 – 固体生物燃料 高位发热量 量热法 范围 低位发热量（计算值） PN-EN ISO 18125:2017-07","technique_zh":"量热法","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料"},{"_id":"6a837a57af14b9c0e7b1fdfa","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","methodology":"Zawartość węgla całkowitego","parameters":[{"name":"Zakres","range":"(8,00 – 60,00) %"},{"name":"Zawartość wodoru"},{"name":"Zakres","range":"(1,00 - 10,00)%"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość węgla całkowitego\nZakres:\nZakres (8,00 – 60,00) %\nZawartość wodoru\nZakres (1,00 - 10,00)%\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN ISO 16948:2015-07","norm_bases":["PN-EN ISO 16948:2015-07"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Zawartość węgla całkowitego\nZakres:\nZakres (8,00 – 60,00) %\nZawartość wodoru\nZakres (1,00 - 10,00)%\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN ISO 16948:2015-07 Paliwa stale: biomasa stala – biopaliwo stale Zawartosc wegla calkowitego\nZakres:\nZakres (8,00 – 60,00) %\nZawartosc wodoru\nZakres (1,00 - 10,00)%\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN ISO 16948:2015-07","categories":["petro"],"row_index":173,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total carbon content","parameters_en":[{"name":"Range","range":"(8,00 – 60,00) %"},{"name":"Hydrogen content"},{"name":"Range","range":"(1,00 - 10,00)%"}],"search_en":"Solid fuels: solid biomass – solid biofuel Total carbon content High-temperature combustion with IR detection Range Hydrogen content Range PN-EN ISO 16948:2015-07","technique_en":"High-temperature combustion with IR detection","test_object_en":"Solid fuels: solid biomass – solid biofuel","methodology_zh":"总碳含量","parameters_zh":[{"name":"范围","range":"(8,00 – 60,00) %"},{"name":"氢含量"},{"name":"范围","range":"(1,00 - 10,00)%"}],"search_zh":"固体燃料：固体生物质 – 固体生物燃料 总碳含量 高温燃烧红外检测法 范围 氢含量 范围 PN-EN ISO 16948:2015-07","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料"},{"_id":"6a837a57af14b9c0e7b1fdfb","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","methodology":"Zawartość azotu","parameters":[{"name":"Zakres","range":"(0,10 – 3,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją TC","techniques":["Metoda wysokotemperaturowego spalania z detekcją TC"],"computed":[],"activity":"Zawartość azotu\nZakres (0,10 – 3,00) %\nMetoda wysokotemperaturowego spalania z detekcją TC","reference":"PN-EN ISO 16948:2015-07","norm_bases":["PN-EN ISO 16948:2015-07"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Zawartość azotu\nZakres (0,10 – 3,00) %\nMetoda wysokotemperaturowego spalania z detekcją TC PN-EN ISO 16948:2015-07 Paliwa stale: biomasa stala – biopaliwo stale Zawartosc azotu\nZakres (0,10 – 3,00) %\nMetoda wysokotemperaturowego spalania z detekcja TC PN-EN ISO 16948:2015-07","categories":["petro"],"row_index":174,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrogen content","parameters_en":[{"name":"Range","range":"(0,10 – 3,00) %"}],"search_en":"Solid fuels: solid biomass – solid biofuel Nitrogen content High-temperature combustion with TC detection Range PN-EN ISO 16948:2015-07","technique_en":"High-temperature combustion with TC detection","test_object_en":"Solid fuels: solid biomass – solid biofuel","methodology_zh":"氮含量","parameters_zh":[{"name":"范围","range":"(0,10 – 3,00) %"}],"search_zh":"固体燃料：固体生物质 – 固体生物燃料 氮含量 高温燃烧总碳检测法 范围 PN-EN ISO 16948:2015-07","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料","technique_zh":"高温燃烧总碳检测法"},{"_id":"6a837a57af14b9c0e7b1fdfc","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","methodology":"Zawartość części lotnych","parameters":[{"name":"Zakres","range":"(10,0 – 85,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość części lotnych\nZakres (10,0 – 85,0) %\nMetoda wagowa","reference":"PN-EN ISO 18123:2023-10","norm_bases":["PN-EN ISO 18123:2023-10"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Zawartość części lotnych\nZakres (10,0 – 85,0) %\nMetoda wagowa PN-EN ISO 18123:2023-10 Paliwa stale: biomasa stala – biopaliwo stale Zawartosc czesci lotnych\nZakres (10,0 – 85,0) %\nMetoda wagowa PN-EN ISO 18123:2023-10","categories":["petro"],"row_index":175,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Volatile matter content","parameters_en":[{"name":"Range","range":"(10,0 – 85,0) %"}],"search_en":"Solid fuels: solid biomass – solid biofuel Volatile matter content Gravimetric method Range PN-EN ISO 18123:2023-10","technique_en":"Gravimetric method","test_object_en":"Solid fuels: solid biomass – solid biofuel","parameters_zh":[{"name":"范围","range":"(10,0 – 85,0) %"}],"search_zh":"固体燃料：固体生物质 – 固体生物燃料 挥发分含量 重量法 范围 PN-EN ISO 18123:2023-10","technique_zh":"重量法","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料","methodology_zh":"挥发分含量"},{"_id":"6a837a57af14b9c0e7b1fdfd","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 24, 10 01 80, 10 01 82, 19 09 03, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Produkt odsiarczania","methodology":"Strata prażenia (części palne)","parameters":[{"name":"Zakres","range":"(0,1 – 50,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Strata prażenia (części palne)\nZakres (0,1 – 50,0) %\nMetoda wagowa","reference":"PN-77/G-04528.02","norm_bases":["PN-77/G-04528.02"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 24, 10 01 80, 10 01 82, 19 09 03, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Produkt odsiarczania Strata prażenia (części palne)\nZakres (0,1 – 50,0) %\nMetoda wagowa PN-77/G-04528.02 Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 24, 10 01 80, 10 01 82, 19 09 03, Popiol, zuzel, Mieszanka popiolowo zuzlowa, Popiol z produktami odsiarczania - lotny, Popiol z produktami odsiarczania - fluidalny, Piaski ze zloz fluidalnych, Produkt odsiarczania Strata prazenia (czesci palne)\nZakres (0,1 – 50,0) %\nMetoda wagowa PN-77/G-04528.02","categories":["environment"],"row_index":176,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Loss on ignition (combustible matter)","parameters_en":[{"name":"Range","range":"(0,1 – 50,0) %"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Loss on ignition (combustible matter) Gravimetric method waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Range PN-77/G-04528.02","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(0,1 – 50,0) %"}],"search_zh":"烧失量（可燃组分） 重量法 依据气候部长关于废物目录的条例的废物代码。 范围 PN-77/G-04528.02","technique_zh":"重量法","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。","methodology_zh":"烧失量（可燃组分）"},{"_id":"6a837a57af14b9c0e7b1fdfe","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 24, 10 01 80, 10 01 82, 19 09 03, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Produkt odsiarczania","methodology":"Zawartość węgla całkowitego","parameters":[{"name":"Zakres","range":"(0,10 – 50,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość węgla całkowitego\nZakres (0,10 – 50,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"IB-DPA-23 wersja 08 z dnia 02-01-2026 r.","norm_bases":["IB-DPA-23 wersja 08 z dnia 02-01-2026 r."],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 24, 10 01 80, 10 01 82, 19 09 03, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Produkt odsiarczania Zawartość węgla całkowitego\nZakres (0,10 – 50,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR IB-DPA-23 wersja 08 z dnia 02-01-2026 r. Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 24, 10 01 80, 10 01 82, 19 09 03, Popiol, zuzel, Mieszanka popiolowo zuzlowa, Popiol z produktami odsiarczania - lotny, Popiol z produktami odsiarczania - fluidalny, Piaski ze zloz fluidalnych, Produkt odsiarczania Zawartosc wegla calkowitego\nZakres (0,10 – 50,00) %\nMetoda wysokotemperaturowego spalania z detekcja IR IB-DPA-23 wersja 08 z dnia 02-01-2026 r.","categories":["environment"],"row_index":177,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total carbon content","parameters_en":[{"name":"Range","range":"(0,10 – 50,00) %"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Total carbon content High-temperature combustion with IR detection waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Range IB-DPA-23 wersja 08 z dnia 02-01-2026 r.","technique_en":"High-temperature combustion with IR detection","methodology_zh":"总碳含量","parameters_zh":[{"name":"范围","range":"(0,10 – 50,00) %"}],"search_zh":"总碳含量 高温燃烧红外检测法 依据气候部长关于废物目录的条例的废物代码。 范围 IB-DPA-23 wersja 08 z dnia 02-01-2026 r.","technique_zh":"高温燃烧红外检测法","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。"},{"_id":"6a837a57af14b9c0e7b1fdff","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 24, 10 01 80, 10 01 82, 19 09 03, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Produkt odsiarczania","methodology":"Strata prażenia (części palne)","parameters":[{"name":"Zakres","range":"(0,01 – 50,00) %"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)"],"computed":[],"activity":"Strata prażenia (części palne)\nZakres (0,01 – 50,00) %\nMetoda termograwimetryczna (TGA)","reference":"IB-DPA-24 wersja 07 z dnia 02-01-2026 r.","norm_bases":["IB-DPA-24 wersja 07 z dnia 02-01-2026 r."],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 24, 10 01 80, 10 01 82, 19 09 03, Popiół, żużel, Mieszanka popiołowo żużlowa, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Produkt odsiarczania Strata prażenia (części palne)\nZakres (0,01 – 50,00) %\nMetoda termograwimetryczna (TGA) IB-DPA-24 wersja 07 z dnia 02-01-2026 r. Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 24, 10 01 80, 10 01 82, 19 09 03, Popiol, zuzel, Mieszanka popiolowo zuzlowa, Popiol z produktami odsiarczania - lotny, Popiol z produktami odsiarczania - fluidalny, Piaski ze zloz fluidalnych, Produkt odsiarczania Strata prazenia (czesci palne)\nZakres (0,01 – 50,00) %\nMetoda termograwimetryczna (TGA) IB-DPA-24 wersja 07 z dnia 02-01-2026 r.","categories":["environment"],"row_index":178,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Loss on ignition (combustible matter)","parameters_en":[{"name":"Range","range":"(0,01 – 50,00) %"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Loss on ignition (combustible matter) Thermogravimetric method (TGA) waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Range IB-DPA-24 wersja 07 z dnia 02-01-2026 r.","technique_en":"Thermogravimetric method (TGA)","parameters_zh":[{"name":"范围","range":"(0,01 – 50,00) %"}],"search_zh":"烧失量（可燃组分） 热重法（TGA） 依据气候部长关于废物目录的条例的废物代码。 范围 IB-DPA-24 wersja 07 z dnia 02-01-2026 r.","technique_zh":"热重法（TGA）","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。","methodology_zh":"烧失量（可燃组分）"},{"_id":"6a837a57af14b9c0e7b1fe00","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Wyroby chemiczne: kamień wapienny, w tym sorbenty wapniowe i węglanowe","methodology":"Zawartość węgla całkowitego","parameters":[{"name":"Zakres","range":"(10,00 – 12,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość węgla całkowitego\nZakres (10,00 – 12,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"IB-DPA-44 wersja 06 z dnia 02-01-2026 r.","norm_bases":["IB-DPA-44 wersja 06 z dnia 02-01-2026 r."],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby chemiczne: kamień wapienny, w tym sorbenty wapniowe i węglanowe Zawartość węgla całkowitego\nZakres (10,00 – 12,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR IB-DPA-44 wersja 06 z dnia 02-01-2026 r. Wyroby chemiczne: kamien wapienny, w tym sorbenty wapniowe i weglanowe Zawartosc wegla calkowitego\nZakres (10,00 – 12,00) %\nMetoda wysokotemperaturowego spalania z detekcja IR IB-DPA-44 wersja 06 z dnia 02-01-2026 r.","categories":["other"],"row_index":179,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total carbon content","parameters_en":[{"name":"Range","range":"(10,00 – 12,00) %"}],"search_en":"Chemical products: limestone, including calcium and carbonate sorbents Total carbon content High-temperature combustion with IR detection Range IB-DPA-44 wersja 06 z dnia 02-01-2026 r.","technique_en":"High-temperature combustion with IR detection","test_object_en":"Chemical products: limestone, including calcium and carbonate sorbents","methodology_zh":"总碳含量","parameters_zh":[{"name":"范围","range":"(10,00 – 12,00) %"}],"search_zh":"化工产品：石灰石，含钙质与碳酸盐吸收剂 总碳含量 高温燃烧红外检测法 范围 IB-DPA-44 wersja 06 z dnia 02-01-2026 r.","technique_zh":"高温燃烧红外检测法","test_object_zh":"化工产品：石灰石，含钙质与碳酸盐吸收剂"},{"_id":"6a837a57af14b9c0e7b1fe01","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Materiał budowalny: gips","methodology":"Uziarnienie Udział procentowy, średnica i rozkład ziaren","parameters":[{"name":"Zakres","range":"(0,50 – 900,00) μm"}],"technique":"Metoda dyfrakcji laserowej","techniques":["Metoda dyfrakcji laserowej"],"computed":[],"activity":"Uziarnienie Udział procentowy, średnica i rozkład ziaren\nZakres (0,50 – 900,00) μm\nMetoda dyfrakcji laserowej","reference":"IB-DPA-39 wersja 06 z dnia 02-01-2026 r.","norm_bases":["IB-DPA-39 wersja 06 z dnia 02-01-2026 r."],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiał budowalny: gips Uziarnienie Udział procentowy, średnica i rozkład ziaren\nZakres (0,50 – 900,00) μm\nMetoda dyfrakcji laserowej IB-DPA-39 wersja 06 z dnia 02-01-2026 r. Material budowalny: gips Uziarnienie Udzial procentowy, srednica i rozklad ziaren\nZakres (0,50 – 900,00) μm\nMetoda dyfrakcji laserowej IB-DPA-39 wersja 06 z dnia 02-01-2026 r.","categories":["materials"],"row_index":180,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Particle size distribution Percentage share, diameter and grain distribution","parameters_en":[{"name":"Range","range":"(0,50 – 900,00) μm"}],"search_en":"Construction material: gypsum Particle size distribution Percentage share, diameter and grain distribution Laser diffraction method Range IB-DPA-39 wersja 06 z dnia 02-01-2026 r.","technique_en":"Laser diffraction method","test_object_en":"Construction material: gypsum","parameters_zh":[{"name":"范围","range":"(0,50 – 900,00) μm"}],"search_zh":"建筑材料：石膏 激光衍射法 范围 IB-DPA-39 wersja 06 z dnia 02-01-2026 r.","technique_zh":"激光衍射法","test_object_zh":"建筑材料：石膏"},{"_id":"6a837a57af14b9c0e7b1fe02","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Materiał budowalny: gips","methodology":"Zawartość wilgoci","parameters":[{"name":"Zakres","range":"(1,0 – 30,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci\nZakres (1,0 – 30,0) %\nMetoda wagowa","reference":"IB-DPA-29 wersja 06 z dnia 02-01-2026 r.","norm_bases":["IB-DPA-29 wersja 06 z dnia 02-01-2026 r."],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiał budowalny: gips Zawartość wilgoci\nZakres (1,0 – 30,0) %\nMetoda wagowa IB-DPA-29 wersja 06 z dnia 02-01-2026 r. Material budowalny: gips Zawartosc wilgoci\nZakres (1,0 – 30,0) %\nMetoda wagowa IB-DPA-29 wersja 06 z dnia 02-01-2026 r.","categories":["materials"],"row_index":181,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Moisture content","parameters_en":[{"name":"Range","range":"(1,0 – 30,0) %"}],"search_en":"Construction material: gypsum Moisture content Gravimetric method Range IB-DPA-29 wersja 06 z dnia 02-01-2026 r.","technique_en":"Gravimetric method","test_object_en":"Construction material: gypsum","parameters_zh":[{"name":"范围","range":"(1,0 – 30,0) %"}],"search_zh":"建筑材料：石膏 水分含量 重量法 范围 IB-DPA-29 wersja 06 z dnia 02-01-2026 r.","technique_zh":"重量法","methodology_zh":"水分含量","test_object_zh":"建筑材料：石膏"},{"_id":"6a837a57af14b9c0e7b1fe03","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Materiał budowalny: gips","methodology":"Zawartość CaSO4 x 2H2O","parameters":[{"name":"Zakres","range":"(70,0 – 99,9) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość CaSO4 x 2H2O\nZakres (70,0 – 99,9) %\nMetoda wagowa","reference":"IB-DPA-30 wersja 06 z dnia 02-01-2026 r.","norm_bases":["IB-DPA-30 wersja 06 z dnia 02-01-2026 r."],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Jaworzno","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiał budowalny: gips Zawartość CaSO4 x 2H2O\nZakres (70,0 – 99,9) %\nMetoda wagowa IB-DPA-30 wersja 06 z dnia 02-01-2026 r. Material budowalny: gips Zawartosc CaSO4 x 2H2O\nZakres (70,0 – 99,9) %\nMetoda wagowa IB-DPA-30 wersja 06 z dnia 02-01-2026 r.","categories":["materials"],"row_index":182,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"CaSO4 x 2H2O content","parameters_en":[{"name":"Range","range":"(70,0 – 99,9) %"}],"search_en":"Construction material: gypsum CaSO4 x 2H2O content Gravimetric method Range IB-DPA-30 wersja 06 z dnia 02-01-2026 r.","technique_en":"Gravimetric method","test_object_en":"Construction material: gypsum","parameters_zh":[{"name":"范围","range":"(70,0 – 99,9) %"}],"search_zh":"建筑材料：石膏 重量法 范围 IB-DPA-30 wersja 06 z dnia 02-01-2026 r.","technique_zh":"重量法","test_object_zh":"建筑材料：石膏"},{"_id":"6a837a57af14b9c0e7b1fe04","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań fizycznych i chemicznych","parameters":[{"name":"Temperatura ścieków / pobranej próbki ścieków"},{"name":"Zakres","range":"(0,0 – 50,0) 0C"},{"name":"pH"},{"name":"Zakres","range":"4,0 – 10,0"}],"technique":"Metoda manualna i automatyczna; Metoda potencjometryczna","techniques":["Metoda manualna i automatyczna","Metoda potencjometryczna"],"computed":[],"activity":"Pobieranie próbek do badań fizycznych i chemicznych\nZakres:\nTemperatura ścieków / pobranej próbki ścieków\nZakres (0,0 – 50,0) 0C\npH\nZakres 4,0 – 10,0\nMetoda manualna i automatyczna; Metoda potencjometryczna","reference":"PN-ISO 5667-10:2021-11 | PN-77/C-04584 | PN-EN ISO 10523:2012","norm_bases":["PN-ISO 5667-10:2021-11","PN-77/C-04584","PN-EN ISO 10523:2012"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Łaziska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań fizycznych i chemicznych\nZakres:\nTemperatura ścieków / pobranej próbki ścieków\nZakres (0,0 – 50,0) 0C\npH\nZakres 4,0 – 10,0\nMetoda manualna i automatyczna; Metoda potencjometryczna PN-ISO 5667-10:2021-11 | PN-77/C-04584 | PN-EN ISO 10523:2012 Scieki Pobieranie probek do badan fizycznych i chemicznych\nZakres:\nTemperatura sciekow / pobranej probki sciekow\nZakres (0,0 – 50,0) 0C\npH\nZakres 4,0 – 10,0\nMetoda manualna i automatyczna; Metoda potencjometryczna PN-ISO 5667-10:2021-11 | PN-77/C-04584 | PN-EN ISO 10523:2012","categories":["water"],"row_index":183,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for physical and chemical testing","parameters_en":[{"name":"Temperature of wastewater / collected wastewater sample"},{"name":"Range","range":"(0,0 – 50,0) 0C"},{"name":"pH"},{"name":"Range","range":"4,0 – 10,0"}],"search_en":"Wastewater Sampling for physical and chemical testing Manual and automatic method; Potentiometric method Temperature of wastewater / collected wastewater sample Range pH Range PN-ISO 5667-10:2021-11 | PN-77/C-04584 | PN-EN ISO 10523:2012","technique_en":"Manual and automatic method; Potentiometric method","test_object_en":"Wastewater","methodology_zh":"物理与化学检测用样品采集","parameters_zh":[{"name":"废水/所采废水样品的温度"},{"name":"范围","range":"(0,0 – 50,0) 0C"},{"name":"pH 值"},{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"污水 物理与化学检测用样品采集 废水/所采废水样品的温度 范围 pH 值 范围 PN-ISO 5667-10:2021-11 | PN-77/C-04584 | PN-EN ISO 10523:2012","test_object_zh":"污水"},{"_id":"6a837a57af14b9c0e7b1fe05","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Woda","methodology":"Pobieranie próbek wód powierzchniowych do badań chemicznych i fizycznych Temperatura pobranej próbki wody","parameters":[{"name":"Zakres","range":"(0,0 – 50,0) 0C"}],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek wód powierzchniowych do badań chemicznych i fizycznych Temperatura pobranej próbki wody\nZakres (0,0 – 50,0) 0C","reference":"PN-EN ISO 5667-6:2016-12 pkt 7.2, 7.3, 7.4 | PN-77/C-04584","norm_bases":["PN-EN ISO 5667-6:2016-12 pkt 7.2, 7.3, 7.4","PN-77/C-04584"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Łaziska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Pobieranie próbek wód powierzchniowych do badań chemicznych i fizycznych Temperatura pobranej próbki wody\nZakres (0,0 – 50,0) 0C PN-EN ISO 5667-6:2016-12 pkt 7.2, 7.3, 7.4 | PN-77/C-04584 Woda Pobieranie probek wod powierzchniowych do badan chemicznych i fizycznych Temperatura pobranej probki wody\nZakres (0,0 – 50,0) 0C PN-EN ISO 5667-6:2016-12 pkt 7.2, 7.3, 7.4 | PN-77/C-04584","categories":["water"],"row_index":184,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Surface water sampling for chemical and physical testing Temperature of the collected water sample","parameters_en":[{"name":"Range","range":"(0,0 – 50,0) 0C"}],"search_en":"Water Surface water sampling for chemical and physical testing Temperature of the collected water sample Range PN-EN ISO 5667-6:2016-12 pkt 7.2, 7.3, 7.4 | PN-77/C-04584","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,0 – 50,0) 0C"}],"search_zh":"水 范围 PN-EN ISO 5667-6:2016-12 pkt 7.2, 7.3, 7.4 | PN-77/C-04584","test_object_zh":"水"},{"_id":"6a837a57af14b9c0e7b1fe06","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Woda","methodology":"Pobieranie próbek wód podziemnych do badań chemicznych i fizycznych Temperatura pobranej próbki wody","parameters":[{"name":"Zakres","range":"(0,0 – 50,0) 0C"},{"name":"Poziom zwierciadła wody"},{"name":"Zakres","range":"(0,00 – 50,0) m"}],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek wód podziemnych do badań chemicznych i fizycznych Temperatura pobranej próbki wody\nZakres:\nZakres (0,0 – 50,0) 0C\nPoziom zwierciadła wody\nZakres (0,00 – 50,0) m","reference":"PN-ISO 5667-11:2017-10 z wyłączeniem pkt 5.2, 6.1.2, 6.2, 6.3 | PN-77/C-04584 | IB-DPA-01 wersja 08 z dnia 02-01-2026 r.","norm_bases":["PN-ISO 5667-11:2017-10 z wyłączeniem pkt 5.2, 6.1.2, 6.2, 6.3","PN-77/C-04584","IB-DPA-01 wersja 08 z dnia 02-01-2026 r."],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Łaziska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Pobieranie próbek wód podziemnych do badań chemicznych i fizycznych Temperatura pobranej próbki wody\nZakres:\nZakres (0,0 – 50,0) 0C\nPoziom zwierciadła wody\nZakres (0,00 – 50,0) m PN-ISO 5667-11:2017-10 z wyłączeniem pkt 5.2, 6.1.2, 6.2, 6.3 | PN-77/C-04584 | IB-DPA-01 wersja 08 z dnia 02-01-2026 r. Woda Pobieranie probek wod podziemnych do badan chemicznych i fizycznych Temperatura pobranej probki wody\nZakres:\nZakres (0,0 – 50,0) 0C\nPoziom zwierciadla wody\nZakres (0,00 – 50,0) m PN-ISO 5667-11:2017-10 z wylaczeniem pkt 5.2, 6.1.2, 6.2, 6.3 | PN-77/C-04584 | IB-DPA-01 wersja 08 z dnia 02-01-2026 r.","categories":["water"],"row_index":185,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Groundwater sampling for chemical and physical testing Temperature of the collected water sample","parameters_en":[{"name":"Range","range":"(0,0 – 50,0) 0C"},{"name":"Poziom zwierciadła wody"},{"name":"Range","range":"(0,00 – 50,0) m"}],"search_en":"Water Groundwater sampling for chemical and physical testing Temperature of the collected water sample Range Range PN-ISO 5667-11:2017-10 z wyłączeniem pkt 5.2, 6.1.2, 6.2, 6.3 | PN-77/C-04584 | IB-DPA-01 wersja 08 z dnia 02-01-2026 r.","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,0 – 50,0) 0C"},{"name":"Poziom zwierciadła wody"},{"name":"范围","range":"(0,00 – 50,0) m"}],"search_zh":"水 范围 范围 PN-ISO 5667-11:2017-10 z wyłączeniem pkt 5.2, 6.1.2, 6.2, 6.3 | PN-77/C-04584 | IB-DPA-01 wersja 08 z dnia 02-01-2026 r.","test_object_zh":"水"},{"_id":"6a837a57af14b9c0e7b1fe07","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Łaziska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Scieki, woda pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":186,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"search_en":"Wastewater, water pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Wastewater, water","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"废水、水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"废水、水"},{"_id":"6a837a57af14b9c0e7b1fe08","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(1,0 – 120000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (1,0 – 120000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Łaziska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Przewodność elektryczna właściwa\nZakres (1,0 – 120000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Scieki, woda Przewodnosc elektryczna wlasciwa\nZakres (1,0 – 120000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":187,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(1,0 – 120000) μS/cm"}],"search_en":"Wastewater, water Electrical conductivity Conductometric method Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Wastewater, water","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(1,0 – 120000) μS/cm"}],"search_zh":"废水、水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"废水、水"},{"_id":"6a837a57af14b9c0e7b1fe09","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)","parameters":[{"name":"Zakres","range":"(2 – 2500) mg/l CaCO3"},{"name":"Zakres","range":"(0,02 – 25,0) mmol/l"},{"name":"Zakres","range":"(0,11 – 140,2) DH0"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres:\nZakres (2 – 2500) mg/l CaCO3\nZakres (0,02 – 25,0) mmol/l\nZakres (0,11 – 140,2) DH0\nMetoda miareczkowa","reference":"PN ISO 6059:1999","norm_bases":["PN ISO 6059:1999"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Łaziska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres:\nZakres (2 – 2500) mg/l CaCO3\nZakres (0,02 – 25,0) mmol/l\nZakres (0,11 – 140,2) DH0\nMetoda miareczkowa PN ISO 6059:1999 Scieki, woda Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna)\nZakres:\nZakres (2 – 2500) mg/l CaCO3\nZakres (0,02 – 25,0) mmol/l\nZakres (0,11 – 140,2) DH0\nMetoda miareczkowa PN ISO 6059:1999","categories":["water"],"row_index":188,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total content of calcium and magnesium (total hardness)","parameters_en":[{"name":"Range","range":"(2 – 2500) mg/l CaCO3"},{"name":"Range","range":"(0,02 – 25,0) mmol/l"},{"name":"Range","range":"(0,11 – 140,2) DH0"}],"search_en":"Wastewater, water Total content of calcium and magnesium (total hardness) Titrimetric method Range Range Range PN ISO 6059:1999","technique_en":"Titrimetric method","test_object_en":"Wastewater, water","methodology_zh":"钙与镁总量（总硬度）","parameters_zh":[{"name":"范围","range":"(2 – 2500) mg/l CaCO3"},{"name":"范围","range":"(0,02 – 25,0) mmol/l"},{"name":"范围","range":"(0,11 – 140,2) DH0"}],"search_zh":"废水、水 钙与镁总量（总硬度） 滴定法 范围 范围 范围 PN ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"废水、水"},{"_id":"6a837a57af14b9c0e7b1fe0a","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Zasadowość ogólna i zasadowość wobec fenoloftaleiny","parameters":[{"name":"Zakres","range":"(0,05 – 20) mmol/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zasadowość ogólna i zasadowość wobec fenoloftaleiny\nZakres (0,05 – 20) mmol/l\nMetoda miareczkowa","reference":"PN-EN ISO 9963-1:2001+Ap1:2004","norm_bases":["PN-EN ISO 9963-1:2001+Ap1:2004"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Łaziska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Zasadowość ogólna i zasadowość wobec fenoloftaleiny\nZakres (0,05 – 20) mmol/l\nMetoda miareczkowa PN-EN ISO 9963-1:2001+Ap1:2004 Scieki, woda Zasadowosc ogolna i zasadowosc wobec fenoloftaleiny\nZakres (0,05 – 20) mmol/l\nMetoda miareczkowa PN-EN ISO 9963-1:2001+Ap1:2004","categories":["water"],"row_index":189,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total alkalinity and phenolphthalein alkalinity","parameters_en":[{"name":"Range","range":"(0,05 – 20) mmol/l"}],"search_en":"Wastewater, water Total alkalinity and phenolphthalein alkalinity Titrimetric method Range PN-EN ISO 9963-1:2001+Ap1:2004","technique_en":"Titrimetric method","test_object_en":"Wastewater, water","parameters_zh":[{"name":"范围","range":"(0,05 – 20) mmol/l"}],"search_zh":"废水、水 总碱度与酚酞碱度 滴定法 范围 PN-EN ISO 9963-1:2001+Ap1:2004","technique_zh":"滴定法","test_object_zh":"废水、水","methodology_zh":"总碱度与酚酞碱度"},{"_id":"6a837a57af14b9c0e7b1fe0b","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Stężenie węglanów, wodorowęglanów, wodorotlenków, twardość węglanowa, twardość niewęglanowa (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie węglanów, wodorowęglanów, wodorotlenków, twardość węglanowa, twardość niewęglanowa (z obliczeń)","reference":"IB-DPA-05 wersja 07 z dnia 02-01-2026 r.","norm_bases":["IB-DPA-05 wersja 07 z dnia 02-01-2026 r."],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Łaziska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Stężenie węglanów, wodorowęglanów, wodorotlenków, twardość węglanowa, twardość niewęglanowa (z obliczeń) IB-DPA-05 wersja 07 z dnia 02-01-2026 r. Scieki, woda Stezenie weglanow, wodoroweglanow, wodorotlenkow, twardosc weglanowa, twardosc nieweglanowa (z obliczen) IB-DPA-05 wersja 07 z dnia 02-01-2026 r.","categories":["water"],"row_index":190,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of carbonates, bicarbonates, hydroxides, carbonate hardness, non-carbonate hardness (calculated)","search_en":"Wastewater, water Concentration of carbonates, bicarbonates, hydroxides, carbonate hardness, non-carbonate hardness (calculated) IB-DPA-05 wersja 07 z dnia 02-01-2026 r.","test_object_en":"Wastewater, water","search_zh":"废水、水 IB-DPA-05 wersja 07 z dnia 02-01-2026 r.","test_object_zh":"废水、水"},{"_id":"6a837a57af14b9c0e7b1fe0c","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Stężenie krzemionki","parameters":[{"name":"Zakres","range":"(0,50 - 25,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie krzemionki\nZakres (0,50 - 25,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6382:2000","norm_bases":["PN-ISO 6382:2000"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Łaziska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Stężenie krzemionki\nZakres (0,50 - 25,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6382:2000 Scieki, woda Stezenie krzemionki\nZakres (0,50 - 25,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6382:2000","categories":["water"],"row_index":191,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Silica concentration","parameters_en":[{"name":"Range","range":"(0,50 - 25,0) mg/l"}],"search_en":"Wastewater, water Silica concentration Spectrophotometric method Range PN-ISO 6382:2000","technique_en":"Spectrophotometric method","test_object_en":"Wastewater, water","parameters_zh":[{"name":"范围","range":"(0,50 - 25,0) mg/l"}],"search_zh":"废水、水 二氧化硅浓度 分光光度法 范围 PN-ISO 6382:2000","technique_zh":"分光光度法","test_object_zh":"废水、水","methodology_zh":"二氧化硅浓度"},{"_id":"6a837a57af14b9c0e7b1fe0d","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(0,05 – 10,0) mg/l"}],"technique":"Metoda turbidymetryczna","techniques":["Metoda turbidymetryczna"],"computed":[],"activity":"Stężenie chlorków\nZakres (0,05 – 10,0) mg/l\nMetoda turbidymetryczna","reference":"PN-76/C-04617.01","norm_bases":["PN-76/C-04617.01"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Łaziska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Stężenie chlorków\nZakres (0,05 – 10,0) mg/l\nMetoda turbidymetryczna PN-76/C-04617.01 Scieki, woda Stezenie chlorkow\nZakres (0,05 – 10,0) mg/l\nMetoda turbidymetryczna PN-76/C-04617.01","categories":["water"],"row_index":192,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(0,05 – 10,0) mg/l"}],"search_en":"Wastewater, water Chloride concentration Turbidimetric method Range PN-76/C-04617.01","technique_en":"Turbidimetric method","test_object_en":"Wastewater, water","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(0,05 – 10,0) mg/l"}],"search_zh":"废水、水 氯化物浓度 浊度法 范围 PN-76/C-04617.01","test_object_zh":"废水、水","technique_zh":"浊度法"},{"_id":"6a837a57af14b9c0e7b1fe0e","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5,0 – 25000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5,0 – 25000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Łaziska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Stężenie chlorków\nZakres (5,0 – 25000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Scieki, woda Stezenie chlorkow\nZakres (5,0 – 25000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":193,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5,0 – 25000) mg/l"}],"search_en":"Wastewater, water Chloride concentration Titrimetric method Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Wastewater, water","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,0 – 25000) mg/l"}],"search_zh":"废水、水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"废水、水"},{"_id":"6a837a57af14b9c0e7b1fe0f","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Stężenie żelaza ogólnego","parameters":[{"name":"Zakres","range":"(0,010 – 15,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza ogólnego\nZakres (0,010 – 15,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001+Ap1:2016-06","norm_bases":["PN-ISO 6332:2001+Ap1:2016-06"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Łaziska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Stężenie żelaza ogólnego\nZakres (0,010 – 15,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06 Scieki, woda Stezenie zelaza ogolnego\nZakres (0,010 – 15,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06","categories":["water"],"row_index":194,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total iron concentration","parameters_en":[{"name":"Range","range":"(0,010 – 15,0) mg/l"}],"search_en":"Wastewater, water Total iron concentration Spectrophotometric method Range PN-ISO 6332:2001+Ap1:2016-06","technique_en":"Spectrophotometric method","test_object_en":"Wastewater, water","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(0,010 – 15,0) mg/l"}],"search_zh":"废水、水 总铁浓度 分光光度法 范围 PN-ISO 6332:2001+Ap1:2016-06","technique_zh":"分光光度法","test_object_zh":"废水、水"},{"_id":"6a837a57af14b9c0e7b1fe10","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0 – 2500) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 2500) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Łaziska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Zawiesiny ogólne\nZakres (2,0 – 2500) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Scieki, woda Zawiesiny ogolne\nZakres (2,0 – 2500) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":195,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2,0 – 2500) mg/l"}],"search_en":"Wastewater, water Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Wastewater, water","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 2500) mg/l"}],"search_zh":"废水、水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"废水、水"},{"_id":"6a837a57af14b9c0e7b1fe11","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Całkowite substancje rozpuszczone (TDS)","parameters":[{"name":"Zakres","range":"(20,0 – 15000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Całkowite substancje rozpuszczone (TDS)\nZakres (20,0 – 15000) mg/l\nMetoda wagowa","reference":"PN-EN 15216:2022-03","norm_bases":["PN-EN 15216:2022-03"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Łaziska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Całkowite substancje rozpuszczone (TDS)\nZakres (20,0 – 15000) mg/l\nMetoda wagowa PN-EN 15216:2022-03 Scieki, woda Calkowite substancje rozpuszczone (TDS)\nZakres (20,0 – 15000) mg/l\nMetoda wagowa PN-EN 15216:2022-03","categories":["water"],"row_index":196,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total dissolved solids (TDS)","parameters_en":[{"name":"Range","range":"(20,0 – 15000) mg/l"}],"search_en":"Wastewater, water Total dissolved solids (TDS) Gravimetric method Range PN-EN 15216:2022-03","technique_en":"Gravimetric method","test_object_en":"Wastewater, water","parameters_zh":[{"name":"范围","range":"(20,0 – 15000) mg/l"}],"search_zh":"废水、水 溶解性总固体（TDS） 重量法 范围 PN-EN 15216:2022-03","technique_zh":"重量法","test_object_zh":"废水、水","methodology_zh":"溶解性总固体（TDS）"},{"_id":"6a837a57af14b9c0e7b1fe12","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Biochemiczne zapotrzebowanie tlenu","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(3 – 250) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3 – 250) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Łaziska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3 – 250) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Scieki, woda Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3 – 250) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":197,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand","parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(3 – 250) mg/l O2"}],"search_en":"Wastewater, water Biochemical oxygen demand Electrochemical method BOD5 Range PN-EN ISO 5815-1:2019-12","technique_en":"Electrochemical method","test_object_en":"Wastewater, water","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(3 – 250) mg/l O2"}],"search_zh":"废水、水 生化需氧量 电化学法 BZT5（BOD5） 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"废水、水"},{"_id":"6a837a57af14b9c0e7b1fe13","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Biochemiczne zapotrzebowanie tlenu","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(0,50 – 6,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,50 – 6,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Łaziska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,50 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Scieki, woda Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,50 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":198,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand","parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(0,50 – 6,0) mg/l O2"}],"search_en":"Wastewater, water Biochemical oxygen demand Electrochemical method BOD5 Range PN-EN 1899-2:2002","technique_en":"Electrochemical method","test_object_en":"Wastewater, water","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(0,50 – 6,0) mg/l O2"}],"search_zh":"废水、水 生化需氧量 电化学法 BZT5（BOD5） 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"废水、水"},{"_id":"6a837a57af14b9c0e7b1fe14","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,05 – 50,0) mg/l"},{"name":"Stężenie amoniaku jako NH3"},{"name":"Zakres","range":"(0,06 – 60,7) mg/l"},{"name":"Stężenie jonu amonowego jako NH4"},{"name":"Zakres","range":"(0,06 – 64,3) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres:\nZakres (0,05 – 50,0) mg/l\nStężenie amoniaku jako NH3\nZakres (0,06 – 60,7) mg/l\nStężenie jonu amonowego jako NH4\nZakres (0,06 – 64,3) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Łaziska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Stężenie azotu amonowego\nZakres:\nZakres (0,05 – 50,0) mg/l\nStężenie amoniaku jako NH3\nZakres (0,06 – 60,7) mg/l\nStężenie jonu amonowego jako NH4\nZakres (0,06 – 64,3) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Scieki, woda Stezenie azotu amonowego\nZakres:\nZakres (0,05 – 50,0) mg/l\nStezenie amoniaku jako NH3\nZakres (0,06 – 60,7) mg/l\nStezenie jonu amonowego jako NH4\nZakres (0,06 – 64,3) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":199,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,05 – 50,0) mg/l"},{"name":"Ammonia concentration as NH3"},{"name":"Range","range":"(0,06 – 60,7) mg/l"},{"name":"Ammonium ion concentration as NH4"},{"name":"Range","range":"(0,06 – 64,3) mg/l"}],"search_en":"Wastewater, water Ammonium nitrogen concentration Spectrophotometric method Range Ammonia concentration as NH3 Range Ammonium ion concentration as NH4 Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Wastewater, water","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,05 – 50,0) mg/l"},{"name":"Stężenie amoniaku jako NH3"},{"name":"范围","range":"(0,06 – 60,7) mg/l"},{"name":"Stężenie jonu amonowego jako NH4"},{"name":"范围","range":"(0,06 – 64,3) mg/l"}],"search_zh":"废水、水 氨氮浓度 分光光度法 范围 范围 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"废水、水"},{"_id":"6a837a57af14b9c0e7b1fe15","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Stężenie azotanów","parameters":[{"name":"Zakres","range":"(0,17 – 225,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotanów\nZakres (0,17 – 225,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576.08","norm_bases":["PN-82/C-04576.08"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Łaziska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Stężenie azotanów\nZakres (0,17 – 225,0) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08 Scieki, woda Stezenie azotanow\nZakres (0,17 – 225,0) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08","categories":["water"],"row_index":200,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate concentration","parameters_en":[{"name":"Range","range":"(0,17 – 225,0) mg/l"}],"search_en":"Wastewater, water Nitrate concentration Spectrophotometric method Range PN-82/C-04576.08","technique_en":"Spectrophotometric method","test_object_en":"Wastewater, water","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,17 – 225,0) mg/l"}],"search_zh":"废水、水 硝酸盐浓度 分光光度法 范围 PN-82/C-04576.08","technique_zh":"分光光度法","test_object_zh":"废水、水"},{"_id":"6a837a57af14b9c0e7b1fe16","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Stężenia azotu azotanowego","parameters":[{"name":"Zakres","range":"(0,04 – 50,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenia azotu azotanowego\nZakres (0,04 – 50,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576.08","norm_bases":["PN-82/C-04576.08"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Łaziska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Stężenia azotu azotanowego\nZakres (0,04 – 50,0) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08 Scieki, woda Stezenia azotu azotanowego\nZakres (0,04 – 50,0) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08","categories":["water"],"row_index":201,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate nitrogen concentrations","parameters_en":[{"name":"Range","range":"(0,04 – 50,0) mg/l"}],"search_en":"Wastewater, water Nitrate nitrogen concentrations Spectrophotometric method Range PN-82/C-04576.08","technique_en":"Spectrophotometric method","test_object_en":"Wastewater, water","parameters_zh":[{"name":"范围","range":"(0,04 – 50,0) mg/l"}],"search_zh":"废水、水 分光光度法 范围 PN-82/C-04576.08","technique_zh":"分光光度法","test_object_zh":"废水、水"},{"_id":"6a837a57af14b9c0e7b1fe17","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Chemiczne zapotrzebowanie tlenu – (ChZT- Cr)","parameters":[{"name":"Zakres","range":"(10,0 – 150) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu – (ChZT- Cr)\nZakres (10,0 – 150) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Łaziska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Chemiczne zapotrzebowanie tlenu – (ChZT- Cr)\nZakres (10,0 – 150) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Scieki, woda Chemiczne zapotrzebowanie tlenu – (ChZT- Cr)\nZakres (10,0 – 150) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":202,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(10,0 – 150) mg/l O2"}],"search_en":"Wastewater, water Spectrophotometric method Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Wastewater, water","parameters_zh":[{"name":"范围","range":"(10,0 – 150) mg/l O2"}],"search_zh":"废水、水 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"废水、水"},{"_id":"6a837a57af14b9c0e7b1fe18","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Stężenie pierwiastków","parameters":[{"name":"Pb","range":"(0,008 – 1,00) mg/l"},{"name":"Zn","range":"(0,010 – 20,0) mg/l"},{"name":"B","range":"(0,010 – 200,0) mg/l"},{"name":"Cr","range":"(0,003 – 1,00) mg/l"},{"name":"Ni","range":"(0,003 – 1,00) mg/l"},{"name":"Co","range":"(0,004 – 0,50) mg/l"},{"name":"Cu","range":"(0,004 – 1,00) mg/l"},{"name":"As","range":"(0,005 – 1,00) mg/l"},{"name":"Cd","range":"(0,0010 – 1,00) mg/l"},{"name":"Mn","range":"(0,0010 – 10,0) mg/l"},{"name":"V","range":"(0,003 – 0,50) mg/l"},{"name":"Na","range":"(0,3 – 5000) mg/l"},{"name":"K","range":"(0,3 – 1000) mg/l"},{"name":"Ca","range":"(2,0 – 2000) mg/l"},{"name":"Mg","range":"(0,5 – 500) mg/l"},{"name":"Ag","range":"(0,010 – 0,50) mg/l"},{"name":"Sr","range":"(0,010 – 50,0) mg/l"},{"name":"Ba","range":"(0,010 – 2,00) mg/l"},{"name":"Al","range":"(0,030 – 10,00) mg/l"},{"name":"Mo","range":"(0,004 – 0,500) mg/l"},{"name":"Se","range":"(0,004 – 0,50) mg/l"},{"name":"Fe","range":"(0,010 – 25,0) mg/l"},{"name":"P","range":"(0,020 – 30,0) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie pierwiastków\nZakres:\nPb (0,008 – 1,00) mg/l\nZn (0,010 – 20,0) mg/l\nB (0,010 – 200,0) mg/l\nCr (0,003 – 1,00) mg/l\nNi (0,003 – 1,00) mg/l\nCo (0,004 – 0,50) mg/l\nCu (0,004 – 1,00) mg/l\nAs (0,005 – 1,00) mg/l\nCd (0,0010 – 1,00) mg/l\nMn (0,0010 – 10,0) mg/l\nV (0,003 – 0,50) mg/l\nNa (0,3 – 5000) mg/l\nK (0,3 – 1000) mg/l\nCa (2,0 – 2000) mg/l\nMg (0,5 – 500) mg/l\nAg (0,010 – 0,50) mg/l\nSr (0,010 – 50,0) mg/l\nBa (0,010 – 2,00) mg/l\nAl (0,030 – 10,00) mg/l\nMo (0,004 – 0,500) mg/l\nSe (0,004 – 0,50) mg/l\nFe (0,010 – 25,0) mg/l\nP (0,020 – 30,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Łaziska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Stężenie pierwiastków\nZakres:\nPb (0,008 – 1,00) mg/l\nZn (0,010 – 20,0) mg/l\nB (0,010 – 200,0) mg/l\nCr (0,003 – 1,00) mg/l\nNi (0,003 – 1,00) mg/l\nCo (0,004 – 0,50) mg/l\nCu (0,004 – 1,00) mg/l\nAs (0,005 – 1,00) mg/l\nCd (0,0010 – 1,00) mg/l\nMn (0,0010 – 10,0) mg/l\nV (0,003 – 0,50) mg/l\nNa (0,3 – 5000) mg/l\nK (0,3 – 1000) mg/l\nCa (2,0 – 2000) mg/l\nMg (0,5 – 500) mg/l\nAg (0,010 – 0,50) mg/l\nSr (0,010 – 50,0) mg/l\nBa (0,010 – 2,00) mg/l\nAl (0,030 – 10,00) mg/l\nMo (0,004 – 0,500) mg/l\nSe (0,004 – 0,50) mg/l\nFe (0,010 – 25,0) mg/l\nP (0,020 – 30,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Scieki, woda Stezenie pierwiastkow\nZakres:\nPb (0,008 – 1,00) mg/l\nZn (0,010 – 20,0) mg/l\nB (0,010 – 200,0) mg/l\nCr (0,003 – 1,00) mg/l\nNi (0,003 – 1,00) mg/l\nCo (0,004 – 0,50) mg/l\nCu (0,004 – 1,00) mg/l\nAs (0,005 – 1,00) mg/l\nCd (0,0010 – 1,00) mg/l\nMn (0,0010 – 10,0) mg/l\nV (0,003 – 0,50) mg/l\nNa (0,3 – 5000) mg/l\nK (0,3 – 1000) mg/l\nCa (2,0 – 2000) mg/l\nMg (0,5 – 500) mg/l\nAg (0,010 – 0,50) mg/l\nSr (0,010 – 50,0) mg/l\nBa (0,010 – 2,00) mg/l\nAl (0,030 – 10,00) mg/l\nMo (0,004 – 0,500) mg/l\nSe (0,004 – 0,50) mg/l\nFe (0,010 – 25,0) mg/l\nP (0,020 – 30,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["water"],"row_index":203,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element concentration","parameters_en":[{"name":"Pb","range":"(0,008 – 1,00) mg/l"},{"name":"Zn","range":"(0,010 – 20,0) mg/l"},{"name":"B","range":"(0,010 – 200,0) mg/l"},{"name":"Cr","range":"(0,003 – 1,00) mg/l"},{"name":"Ni","range":"(0,003 – 1,00) mg/l"},{"name":"Co","range":"(0,004 – 0,50) mg/l"},{"name":"Cu","range":"(0,004 – 1,00) mg/l"},{"name":"As","range":"(0,005 – 1,00) mg/l"},{"name":"Cd","range":"(0,0010 – 1,00) mg/l"},{"name":"Mn","range":"(0,0010 – 10,0) mg/l"},{"name":"V","range":"(0,003 – 0,50) mg/l"},{"name":"Na","range":"(0,3 – 5000) mg/l"},{"name":"K","range":"(0,3 – 1000) mg/l"},{"name":"Ca","range":"(2,0 – 2000) mg/l"},{"name":"Mg","range":"(0,5 – 500) mg/l"},{"name":"Ag","range":"(0,010 – 0,50) mg/l"},{"name":"Sr","range":"(0,010 – 50,0) mg/l"},{"name":"Ba","range":"(0,010 – 2,00) mg/l"},{"name":"Al","range":"(0,030 – 10,00) mg/l"},{"name":"Mo","range":"(0,004 – 0,500) mg/l"},{"name":"Se","range":"(0,004 – 0,50) mg/l"},{"name":"Fe","range":"(0,010 – 25,0) mg/l"},{"name":"P","range":"(0,020 – 30,0) mg/l"}],"search_en":"Wastewater, water Element concentration Inductively coupled plasma optical emission spectrometry (ICP-OES) Pb Zn B Cr Ni Co Cu As Cd Mn V Na K Ca Mg Ag Sr Ba Al Mo Se Fe P PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Wastewater, water","methodology_zh":"元素浓度","parameters_zh":[{"name":"Pb","range":"(0,008 – 1,00) mg/l"},{"name":"Zn","range":"(0,010 – 20,0) mg/l"},{"name":"B","range":"(0,010 – 200,0) mg/l"},{"name":"Cr","range":"(0,003 – 1,00) mg/l"},{"name":"Ni","range":"(0,003 – 1,00) mg/l"},{"name":"Co","range":"(0,004 – 0,50) mg/l"},{"name":"Cu","range":"(0,004 – 1,00) mg/l"},{"name":"As","range":"(0,005 – 1,00) mg/l"},{"name":"Cd","range":"(0,0010 – 1,00) mg/l"},{"name":"Mn","range":"(0,0010 – 10,0) mg/l"},{"name":"V","range":"(0,003 – 0,50) mg/l"},{"name":"Na","range":"(0,3 – 5000) mg/l"},{"name":"K","range":"(0,3 – 1000) mg/l"},{"name":"Ca","range":"(2,0 – 2000) mg/l"},{"name":"Mg","range":"(0,5 – 500) mg/l"},{"name":"Ag","range":"(0,010 – 0,50) mg/l"},{"name":"Sr","range":"(0,010 – 50,0) mg/l"},{"name":"Ba","range":"(0,010 – 2,00) mg/l"},{"name":"Al","range":"(0,030 – 10,00) mg/l"},{"name":"Mo","range":"(0,004 – 0,500) mg/l"},{"name":"Se","range":"(0,004 – 0,50) mg/l"},{"name":"Fe","range":"(0,010 – 25,0) mg/l"},{"name":"P","range":"(0,020 – 30,0) mg/l"}],"search_zh":"废水、水 元素浓度 电感耦合等离子体原子发射光谱法（ICP-OES） Pb Zn B Cr Ni Co Cu As Cd Mn V Na K Ca Mg Ag Sr Ba Al Mo Se Fe P PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"废水、水"},{"_id":"6a837a57af14b9c0e7b1fe19","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Stężenie pierwiastków","parameters":[{"name":"Cu","range":"(0,0005 – 0,050) mg/l"},{"name":"Cd","range":"(0,0002 – 0,010) mg/l"},{"name":"Sb","range":"(0,001 – 0,500) mg/l"},{"name":"Pb","range":"(0,0050 – 0,500) mg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)"],"computed":[],"activity":"Stężenie pierwiastków\nZakres:\nCu (0,0005 – 0,050) mg/l\nCd (0,0002 – 0,010) mg/l\nSb (0,001 – 0,500) mg/l\nPb (0,0050 – 0,500) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","reference":"PN-EN ISO 15586:2005","norm_bases":["PN-EN ISO 15586:2005"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Łaziska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Stężenie pierwiastków\nZakres:\nCu (0,0005 – 0,050) mg/l\nCd (0,0002 – 0,010) mg/l\nSb (0,001 – 0,500) mg/l\nPb (0,0050 – 0,500) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS) PN-EN ISO 15586:2005 Scieki, woda Stezenie pierwiastkow\nZakres:\nCu (0,0005 – 0,050) mg/l\nCd (0,0002 – 0,010) mg/l\nSb (0,001 – 0,500) mg/l\nPb (0,0050 – 0,500) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacja elektrotermiczna (ETAAS) PN-EN ISO 15586:2005","categories":["water"],"row_index":204,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element concentration","parameters_en":[{"name":"Cu","range":"(0,0005 – 0,050) mg/l"},{"name":"Cd","range":"(0,0002 – 0,010) mg/l"},{"name":"Sb","range":"(0,001 – 0,500) mg/l"},{"name":"Pb","range":"(0,0050 – 0,500) mg/l"}],"search_en":"Wastewater, water Element concentration Electrothermal atomization atomic absorption spectrometry (ETAAS) Cu Cd Sb Pb PN-EN ISO 15586:2005","technique_en":"Electrothermal atomization atomic absorption spectrometry (ETAAS)","test_object_en":"Wastewater, water","methodology_zh":"元素浓度","parameters_zh":[{"name":"Cu","range":"(0,0005 – 0,050) mg/l"},{"name":"Cd","range":"(0,0002 – 0,010) mg/l"},{"name":"Sb","range":"(0,001 – 0,500) mg/l"},{"name":"Pb","range":"(0,0050 – 0,500) mg/l"}],"search_zh":"废水、水 元素浓度 电热原子化原子吸收光谱法（ETAAS） Cu Cd Sb Pb PN-EN ISO 15586:2005","technique_zh":"电热原子化原子吸收光谱法（ETAAS）","test_object_zh":"废水、水"},{"_id":"6a837a57af14b9c0e7b1fe1a","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,50 – 1000) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,50 – 1000) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Łaziska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Mętność\nZakres (0,50 – 1000) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Scieki, woda Metnosc\nZakres (0,50 – 1000) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":205,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,50 – 1000) NTU"}],"search_en":"Wastewater, water Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09","technique_en":"Nephelometric method","test_object_en":"Wastewater, water","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,50 – 1000) NTU"}],"search_zh":"废水、水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"废水、水"},{"_id":"6a837a57af14b9c0e7b1fe1b","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(2 – 500) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Barwa\nZakres (2 – 500) mg/l Pt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012 metoda C +Ap1:2015-06","norm_bases":["PN-EN ISO 7887:2012 metoda C +Ap1:2015-06"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Łaziska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Barwa\nZakres (2 – 500) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 metoda C +Ap1:2015-06 Scieki, woda Barwa\nZakres (2 – 500) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 metoda C +Ap1:2015-06","categories":["water"],"row_index":206,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"(2 – 500) mg/l Pt"}],"search_en":"Wastewater, water Colour Spectrophotometric method Range PN-EN ISO 7887:2012 metoda C +Ap1:2015-06","technique_en":"Spectrophotometric method","test_object_en":"Wastewater, water","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(2 – 500) mg/l Pt"}],"search_zh":"废水、水 色度 分光光度法 范围 PN-EN ISO 7887:2012 metoda C +Ap1:2015-06","technique_zh":"分光光度法","test_object_zh":"废水、水"},{"_id":"6a837a57af14b9c0e7b1fe1c","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Indeks nadmanganianowy","parameters":[{"name":"Zakres","range":"(0,50 – 120) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Indeks nadmanganianowy\nZakres (0,50 – 120) mg/l\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Łaziska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Indeks nadmanganianowy\nZakres (0,50 – 120) mg/l\nMetoda miareczkowa PN-EN ISO 8467:2001 Scieki, woda Indeks nadmanganianowy\nZakres (0,50 – 120) mg/l\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":207,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Permanganate index","parameters_en":[{"name":"Range","range":"(0,50 – 120) mg/l"}],"search_en":"Wastewater, water Permanganate index Titrimetric method Range PN-EN ISO 8467:2001","technique_en":"Titrimetric method","test_object_en":"Wastewater, water","methodology_zh":"高锰酸盐指数","parameters_zh":[{"name":"范围","range":"(0,50 – 120) mg/l"}],"search_zh":"废水、水 高锰酸盐指数 滴定法 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"废水、水"},{"_id":"6a837a57af14b9c0e7b1fe1d","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Stężenie fosforanów","parameters":[{"name":"Zakres","range":"(0,090 – 50,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforanów\nZakres (0,090 – 50,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 pkt 4 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 pkt 4 +Ap1:2010+Ap2:2010"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Łaziska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Stężenie fosforanów\nZakres (0,090 – 50,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt 4 +Ap1:2010+Ap2:2010 Scieki, woda Stezenie fosforanow\nZakres (0,090 – 50,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt 4 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":208,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phosphate concentration","parameters_en":[{"name":"Range","range":"(0,090 – 50,0) mg/l"}],"search_en":"Wastewater, water Phosphate concentration Spectrophotometric method Range PN-EN ISO 6878:2006 pkt 4 +Ap1:2010+Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Wastewater, water","parameters_zh":[{"name":"范围","range":"(0,090 – 50,0) mg/l"}],"search_zh":"废水、水 磷酸盐浓度 分光光度法 范围 PN-EN ISO 6878:2006 pkt 4 +Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"废水、水","methodology_zh":"磷酸盐浓度"},{"_id":"6a837a57af14b9c0e7b1fe1e","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Stężenie azotynów","parameters":[{"name":"Zakres","range":"(0,08 – 5,0) mg/l"},{"name":"Stężenie azotu azotynowego"},{"name":"Zakres","range":"(0,024 – 1,5) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotynów\nZakres:\nZakres (0,08 – 5,0) mg/l\nStężenie azotu azotynowego\nZakres (0,024 – 1,5) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Łaziska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Stężenie azotynów\nZakres:\nZakres (0,08 – 5,0) mg/l\nStężenie azotu azotynowego\nZakres (0,024 – 1,5) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Scieki, woda Stezenie azotynow\nZakres:\nZakres (0,08 – 5,0) mg/l\nStezenie azotu azotynowego\nZakres (0,024 – 1,5) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":209,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite concentration","parameters_en":[{"name":"Range","range":"(0,08 – 5,0) mg/l"},{"name":"Nitrite nitrogen concentration"},{"name":"Range","range":"(0,024 – 1,5) mg/l"}],"search_en":"Wastewater, water Nitrite concentration Spectrophotometric method Range Nitrite nitrogen concentration Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Wastewater, water","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,08 – 5,0) mg/l"},{"name":"亚硝态氮浓度"},{"name":"范围","range":"(0,024 – 1,5) mg/l"}],"search_zh":"废水、水 亚硝酸盐浓度 分光光度法 范围 亚硝态氮浓度 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"废水、水"},{"_id":"6a837a57af14b9c0e7b1fe1f","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(0,20 – 100) mg/l"}],"technique":"Metoda miareczkowania potencjometrycznego","techniques":["Metoda miareczkowania potencjometrycznego"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (0,20 – 100) mg/l\nMetoda miareczkowania potencjometrycznego","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Łaziska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Stężenie azotu Kjeldahla\nZakres (0,20 – 100) mg/l\nMetoda miareczkowania potencjometrycznego PN-EN 25663:2001 Scieki, woda Stezenie azotu Kjeldahla\nZakres (0,20 – 100) mg/l\nMetoda miareczkowania potencjometrycznego PN-EN 25663:2001","categories":["water"],"row_index":210,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,20 – 100) mg/l"}],"search_en":"Wastewater, water Kjeldahl nitrogen concentration Potentiometric titration method Range PN-EN 25663:2001","technique_en":"Potentiometric titration method","test_object_en":"Wastewater, water","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(0,20 – 100) mg/l"}],"search_zh":"废水、水 凯氏氮浓度 电位滴定法 范围 PN-EN 25663:2001","technique_zh":"电位滴定法","test_object_zh":"废水、水"},{"_id":"6a837a57af14b9c0e7b1fe20","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Azot ogólny (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Azot ogólny (z obliczeń)","reference":"PN-73/C-04576/14","norm_bases":["PN-73/C-04576/14"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Łaziska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Azot ogólny (z obliczeń) PN-73/C-04576/14 Scieki, woda Azot ogolny (z obliczen) PN-73/C-04576/14","categories":["water"],"row_index":211,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total nitrogen (calculated)","search_en":"Wastewater, water Total nitrogen (calculated) PN-73/C-04576/14","test_object_en":"Wastewater, water","search_zh":"废水、水 总氮（由计算得出） PN-73/C-04576/14","test_object_zh":"废水、水","methodology_zh":"总氮（由计算得出）"},{"_id":"6a837a57af14b9c0e7b1fe21","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Stężenie azotu ogólnego","parameters":[{"name":"Zakres","range":"(0,50 – 150) mg/l"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją chemiluminescencyjną","techniques":["Metoda wysokotemperaturowego spalania z detekcją chemiluminescencyjną"],"computed":[],"activity":"Stężenie azotu ogólnego\nZakres (0,50 – 150) mg/l\nMetoda wysokotemperaturowego spalania z detekcją chemiluminescencyjną","reference":"PN-EN ISO 20236:2025-05","norm_bases":["PN-EN ISO 20236:2025-05"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Łaziska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Stężenie azotu ogólnego\nZakres (0,50 – 150) mg/l\nMetoda wysokotemperaturowego spalania z detekcją chemiluminescencyjną PN-EN ISO 20236:2025-05 Scieki, woda Stezenie azotu ogolnego\nZakres (0,50 – 150) mg/l\nMetoda wysokotemperaturowego spalania z detekcja chemiluminescencyjna PN-EN ISO 20236:2025-05","categories":["water"],"row_index":212,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,50 – 150) mg/l"}],"search_en":"Wastewater, water Total nitrogen concentration High-temperature combustion with chemiluminescence detection Range PN-EN ISO 20236:2025-05","technique_en":"High-temperature combustion with chemiluminescence detection","test_object_en":"Wastewater, water","methodology_zh":"总氮浓度","parameters_zh":[{"name":"范围","range":"(0,50 – 150) mg/l"}],"search_zh":"废水、水 总氮浓度 高温燃烧-化学发光检测法 范围 PN-EN ISO 20236:2025-05","test_object_zh":"废水、水","technique_zh":"高温燃烧-化学发光检测法"},{"_id":"6a837a57af14b9c0e7b1fe22","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Stężenie anionów","parameters":[{"name":"Chlorki","range":"(2,0 – 30000) mg/l"},{"name":"Siarczany","range":"(2,0 - 3000) mg/l"},{"name":"Fosforany","range":"(0,20 – 40,0) mg/l"},{"name":"Fluorki","range":"(0,05 – 25,0) mg/l"},{"name":"Azotany","range":"(0,10 - 100) mg/l"},{"name":"Azotyny","range":"(0,10 – 10,0) mg/l"},{"name":"Azot azotanowy","range":"(0,023 – 22,6) mg/l"},{"name":"Azotyny","range":"(0,10 – 10,0) mg/l"},{"name":"Azot azotynowy","range":"(0,030 – 3,0) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie anionów\nZakres:\nChlorki (2,0 – 30000) mg/l\nSiarczany (2,0 - 3000) mg/l\nFosforany (0,20 – 40,0) mg/l\nFluorki (0,05 – 25,0) mg/l\nAzotany (0,10 - 100) mg/l\nAzotyny (0,10 – 10,0) mg/l\nAzot azotanowy (0,023 – 22,6) mg/l\nAzotyny (0,10 – 10,0) mg/l\nAzot azotynowy (0,030 – 3,0) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Łaziska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Stężenie anionów\nZakres:\nChlorki (2,0 – 30000) mg/l\nSiarczany (2,0 - 3000) mg/l\nFosforany (0,20 – 40,0) mg/l\nFluorki (0,05 – 25,0) mg/l\nAzotany (0,10 - 100) mg/l\nAzotyny (0,10 – 10,0) mg/l\nAzot azotanowy (0,023 – 22,6) mg/l\nAzotyny (0,10 – 10,0) mg/l\nAzot azotynowy (0,030 – 3,0) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Scieki, woda Stezenie anionow\nZakres:\nChlorki (2,0 – 30000) mg/l\nSiarczany (2,0 - 3000) mg/l\nFosforany (0,20 – 40,0) mg/l\nFluorki (0,05 – 25,0) mg/l\nAzotany (0,10 - 100) mg/l\nAzotyny (0,10 – 10,0) mg/l\nAzot azotanowy (0,023 – 22,6) mg/l\nAzotyny (0,10 – 10,0) mg/l\nAzot azotynowy (0,030 – 3,0) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":213,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Anion concentrations","parameters_en":[{"name":"Chlorides","range":"(2,0 – 30000) mg/l"},{"name":"Sulfates","range":"(2,0 - 3000) mg/l"},{"name":"Phosphates","range":"(0,20 – 40,0) mg/l"},{"name":"Fluorides","range":"(0,05 – 25,0) mg/l"},{"name":"Nitrates","range":"(0,10 - 100) mg/l"},{"name":"Nitrites","range":"(0,10 – 10,0) mg/l"},{"name":"Nitrate nitrogen","range":"(0,023 – 22,6) mg/l"},{"name":"Nitrites","range":"(0,10 – 10,0) mg/l"},{"name":"Nitrite nitrogen","range":"(0,030 – 3,0) mg/l"}],"search_en":"Wastewater, water Anion concentrations Ion chromatography with conductometric detection (IC-CD) Chlorides Sulfates Phosphates Fluorides Nitrates Nitrites Nitrate nitrogen Nitrites Nitrite nitrogen PN-EN ISO 10304-1:2009+AC:2012","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Wastewater, water","methodology_zh":"阴离子浓度","parameters_zh":[{"name":"氯化物","range":"(2,0 – 30000) mg/l"},{"name":"硫酸盐","range":"(2,0 - 3000) mg/l"},{"name":"磷酸盐","range":"(0,20 – 40,0) mg/l"},{"name":"氟化物","range":"(0,05 – 25,0) mg/l"},{"name":"硝酸盐","range":"(0,10 - 100) mg/l"},{"name":"亚硝酸盐","range":"(0,10 – 10,0) mg/l"},{"name":"硝酸盐氮","range":"(0,023 – 22,6) mg/l"},{"name":"亚硝酸盐","range":"(0,10 – 10,0) mg/l"},{"name":"Azot azotynowy","range":"(0,030 – 3,0) mg/l"}],"search_zh":"废水、水 阴离子浓度 离子色谱-电导检测法（IC-CD） 氯化物 硫酸盐 磷酸盐 氟化物 硝酸盐 亚硝酸盐 硝酸盐氮 亚硝酸盐 PN-EN ISO 10304-1:2009+AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"废水、水"},{"_id":"6a837a57af14b9c0e7b1fe23","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Stężenie anionów","parameters":[{"name":"Siarczyny","range":"(0,10 – 20) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie anionów\nSiarczyny (0,10 – 20) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-3:2001","norm_bases":["PN-EN ISO 10304-3:2001"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Łaziska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Stężenie anionów\nSiarczyny (0,10 – 20) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-3:2001 Scieki, woda Stezenie anionow\nSiarczyny (0,10 – 20) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-3:2001","categories":["water"],"row_index":214,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Anion concentrations","parameters_en":[{"name":"Sulfites","range":"(0,10 – 20) mg/l"}],"search_en":"Wastewater, water Anion concentrations Ion chromatography with conductometric detection (IC-CD) Sulfites PN-EN ISO 10304-3:2001","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Wastewater, water","methodology_zh":"阴离子浓度","search_zh":"废水、水 阴离子浓度 离子色谱-电导检测法（IC-CD） PN-EN ISO 10304-3:2001","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"废水、水"},{"_id":"6a837a57af14b9c0e7b1fe24","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Substancje ekstrahujące się eterem naftowym","parameters":[{"name":"Zakres","range":"(2,00 – 100) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Substancje ekstrahujące się eterem naftowym\nZakres (2,00 – 100) mg/l\nMetoda wagowa","reference":"IB-DPA-06 wersja 06 z dnia 02-01-2026 r.","norm_bases":["IB-DPA-06 wersja 06 z dnia 02-01-2026 r."],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Łaziska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Substancje ekstrahujące się eterem naftowym\nZakres (2,00 – 100) mg/l\nMetoda wagowa IB-DPA-06 wersja 06 z dnia 02-01-2026 r. Scieki, woda Substancje ekstrahujace sie eterem naftowym\nZakres (2,00 – 100) mg/l\nMetoda wagowa IB-DPA-06 wersja 06 z dnia 02-01-2026 r.","categories":["water"],"row_index":215,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Substances extractable with petroleum ether","parameters_en":[{"name":"Range","range":"(2,00 – 100) mg/l"}],"search_en":"Wastewater, water Substances extractable with petroleum ether Gravimetric method Range IB-DPA-06 wersja 06 z dnia 02-01-2026 r.","technique_en":"Gravimetric method","test_object_en":"Wastewater, water","parameters_zh":[{"name":"范围","range":"(2,00 – 100) mg/l"}],"search_zh":"废水、水 石油醚可萃取物 重量法 范围 IB-DPA-06 wersja 06 z dnia 02-01-2026 r.","technique_zh":"重量法","test_object_zh":"废水、水","methodology_zh":"石油醚可萃取物"},{"_id":"6a837a57af14b9c0e7b1fe25","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Indeks fenolowy","parameters":[{"name":"Zakres","range":"(0,005 – 1,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Indeks fenolowy\nZakres (0,005 – 1,00) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6439:1994 metoda B","norm_bases":["PN-ISO 6439:1994 metoda B"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Łaziska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Indeks fenolowy\nZakres (0,005 – 1,00) mg/l\nMetoda spektrofotometryczna PN-ISO 6439:1994 metoda B Scieki, woda Indeks fenolowy\nZakres (0,005 – 1,00) mg/l\nMetoda spektrofotometryczna PN-ISO 6439:1994 metoda B","categories":["water"],"row_index":216,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phenol index","parameters_en":[{"name":"Range","range":"(0,005 – 1,00) mg/l"}],"search_en":"Wastewater, water Phenol index Spectrophotometric method Range PN-ISO 6439:1994 metoda B","technique_en":"Spectrophotometric method","test_object_en":"Wastewater, water","parameters_zh":[{"name":"范围","range":"(0,005 – 1,00) mg/l"}],"search_zh":"废水、水 酚指数 分光光度法 范围 PN-ISO 6439:1994 metoda B","technique_zh":"分光光度法","test_object_zh":"废水、水","methodology_zh":"酚指数"},{"_id":"6a837a57af14b9c0e7b1fe26","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Indeks oleju mineralnego","parameters":[{"name":"Zakres","range":"(0,10 – 100) mg/l"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Indeks oleju mineralnego\nZakres (0,10 – 100) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PN-EN ISO 9377-2:2003","norm_bases":["PN-EN ISO 9377-2:2003"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Łaziska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Indeks oleju mineralnego\nZakres (0,10 – 100) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PN-EN ISO 9377-2:2003 Scieki, woda Indeks oleju mineralnego\nZakres (0,10 – 100) mg/l\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PN-EN ISO 9377-2:2003","categories":["water","petro"],"row_index":217,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mineral oil index","parameters_en":[{"name":"Range","range":"(0,10 – 100) mg/l"}],"search_en":"Wastewater, water Mineral oil index Gas chromatography with flame ionization detection (GC-FID) Range PN-EN ISO 9377-2:2003","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Wastewater, water","parameters_zh":[{"name":"范围","range":"(0,10 – 100) mg/l"}],"search_zh":"废水、水 矿物油指数 气相色谱-火焰离子化检测法（GC-FID） 范围 PN-EN ISO 9377-2:2003","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"废水、水","methodology_zh":"矿物油指数"},{"_id":"6a837a57af14b9c0e7b1fe27","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Ogólny węgiel organiczny (OWO) Rozpuszczony węgiel organiczny (RWO)","parameters":[{"name":"Zakres","range":"(0,50 – 1000) mg/l"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Ogólny węgiel organiczny (OWO) Rozpuszczony węgiel organiczny (RWO)\nZakres (0,50 – 1000) mg/l\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN 1484:1999","norm_bases":["PN-EN 1484:1999"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Łaziska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Ogólny węgiel organiczny (OWO) Rozpuszczony węgiel organiczny (RWO)\nZakres (0,50 – 1000) mg/l\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN 1484:1999 Scieki, woda Ogolny wegiel organiczny (OWO) Rozpuszczony wegiel organiczny (RWO)\nZakres (0,50 – 1000) mg/l\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN 1484:1999","categories":["water"],"row_index":218,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total organic carbon (TOC) Dissolved organic carbon (DOC)","parameters_en":[{"name":"Range","range":"(0,50 – 1000) mg/l"}],"search_en":"Wastewater, water Total organic carbon (TOC) Dissolved organic carbon (DOC) High-temperature combustion with IR detection Range PN-EN 1484:1999","technique_en":"High-temperature combustion with IR detection","test_object_en":"Wastewater, water","parameters_zh":[{"name":"范围","range":"(0,50 – 1000) mg/l"}],"search_zh":"废水、水 高温燃烧红外检测法 范围 PN-EN 1484:1999","technique_zh":"高温燃烧红外检测法","test_object_zh":"废水、水"},{"_id":"6a837a57af14b9c0e7b1fe28","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Stężenie cyjanków wolnych","parameters":[{"name":"Zakres","range":"(0,005 – 1,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie cyjanków wolnych\nZakres (0,005 – 1,00) mg/l\nMetoda spektrofotometryczna","reference":"PN-80/C-04603/01 z wyłączeniem pkt.7 | IB-DPA-18 wersja 03 z dnia 02-01-2026 r.","norm_bases":["PN-80/C-04603/01 z wyłączeniem pkt.7","IB-DPA-18 wersja 03 z dnia 02-01-2026 r."],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Łaziska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Stężenie cyjanków wolnych\nZakres (0,005 – 1,00) mg/l\nMetoda spektrofotometryczna PN-80/C-04603/01 z wyłączeniem pkt.7 | IB-DPA-18 wersja 03 z dnia 02-01-2026 r. Scieki, woda Stezenie cyjankow wolnych\nZakres (0,005 – 1,00) mg/l\nMetoda spektrofotometryczna PN-80/C-04603/01 z wylaczeniem pkt.7 | IB-DPA-18 wersja 03 z dnia 02-01-2026 r.","categories":["water"],"row_index":219,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free cyanide concentration","parameters_en":[{"name":"Range","range":"(0,005 – 1,00) mg/l"}],"search_en":"Wastewater, water Free cyanide concentration Spectrophotometric method Range PN-80/C-04603/01 z wyłączeniem pkt.7 | IB-DPA-18 wersja 03 z dnia 02-01-2026 r.","technique_en":"Spectrophotometric method","test_object_en":"Wastewater, water","parameters_zh":[{"name":"范围","range":"(0,005 – 1,00) mg/l"}],"search_zh":"废水、水 游离氰化物浓度 分光光度法 范围 PN-80/C-04603/01 z wyłączeniem pkt.7 | IB-DPA-18 wersja 03 z dnia 02-01-2026 r.","technique_zh":"分光光度法","test_object_zh":"废水、水","methodology_zh":"游离氰化物浓度"},{"_id":"6a837a57af14b9c0e7b1fe29","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Stężenie siarczków i siarkowodoru","parameters":[{"name":"Zakres","range":"(0,005 – 100,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie siarczków i siarkowodoru\nZakres (0,005 – 100,0) mg/l\nMetoda spektrofotometryczna","reference":"IB-DPA- 92 wersja 04 z dnia 02-01-2026 r. | na podstawie testu HACH nr 8131","norm_bases":["IB-DPA- 92 wersja 04 z dnia 02-01-2026 r.","na podstawie testu HACH nr 8131"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Łaziska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Stężenie siarczków i siarkowodoru\nZakres (0,005 – 100,0) mg/l\nMetoda spektrofotometryczna IB-DPA- 92 wersja 04 z dnia 02-01-2026 r. | na podstawie testu HACH nr 8131 Scieki, woda Stezenie siarczkow i siarkowodoru\nZakres (0,005 – 100,0) mg/l\nMetoda spektrofotometryczna IB-DPA- 92 wersja 04 z dnia 02-01-2026 r. | na podstawie testu HACH nr 8131","categories":["water"],"row_index":220,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulphide and hydrogen sulphide concentration","parameters_en":[{"name":"Range","range":"(0,005 – 100,0) mg/l"}],"search_en":"Wastewater, water Sulphide and hydrogen sulphide concentration Spectrophotometric method Range IB-DPA- 92 wersja 04 z dnia 02-01-2026 r. | na podstawie testu HACH nr 8131","technique_en":"Spectrophotometric method","test_object_en":"Wastewater, water","parameters_zh":[{"name":"范围","range":"(0,005 – 100,0) mg/l"}],"search_zh":"废水、水 硫化物与硫化氢浓度 分光光度法 范围 IB-DPA- 92 wersja 04 z dnia 02-01-2026 r. | na podstawie testu HACH nr 8131","technique_zh":"分光光度法","test_object_zh":"废水、水","methodology_zh":"硫化物与硫化氢浓度"},{"_id":"6a837a57af14b9c0e7b1fe2a","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Stężenie rtęci","parameters":[{"name":"Zakres","range":"(0,030 – 100) μg/l"}],"technique":"Metoda atomowej spektrometrii fluorescencyjnej","techniques":["Metoda atomowej spektrometrii fluorescencyjnej"],"computed":[],"activity":"Stężenie rtęci\nZakres (0,030 – 100) μg/l\nMetoda atomowej spektrometrii fluorescencyjnej","reference":"PN-EN ISO 17852:2009","norm_bases":["PN-EN ISO 17852:2009"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Łaziska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Stężenie rtęci\nZakres (0,030 – 100) μg/l\nMetoda atomowej spektrometrii fluorescencyjnej PN-EN ISO 17852:2009 Scieki, woda Stezenie rteci\nZakres (0,030 – 100) μg/l\nMetoda atomowej spektrometrii fluorescencyjnej PN-EN ISO 17852:2009","categories":["water"],"row_index":221,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury concentration","parameters_en":[{"name":"Range","range":"(0,030 – 100) μg/l"}],"search_en":"Wastewater, water Mercury concentration Atomic fluorescence spectrometry Range PN-EN ISO 17852:2009","technique_en":"Atomic fluorescence spectrometry","test_object_en":"Wastewater, water","methodology_zh":"汞浓度","parameters_zh":[{"name":"范围","range":"(0,030 – 100) μg/l"}],"search_zh":"废水、水 汞浓度 原子荧光光谱法 范围 PN-EN ISO 17852:2009","test_object_zh":"废水、水","technique_zh":"原子荧光光谱法"},{"_id":"6a837a57af14b9c0e7b1fe2b","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie chromu (VI)","parameters":[{"name":"Zakres","range":"(0,005 – 1,0) mg/l"},{"name":"Stężenie chromu (III) (z obliczeń)"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chromu (VI)\nZakres:\nZakres (0,005 – 1,0) mg/l\nStężenie chromu (III) (z obliczeń)\nMetoda spektrofotometryczna","reference":"PN-EN ISO 18412:2007 | IB-DPA-173 wersja 04 z dnia 02-01-2026 r.","norm_bases":["PN-EN ISO 18412:2007","IB-DPA-173 wersja 04 z dnia 02-01-2026 r."],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Łaziska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie chromu (VI)\nZakres:\nZakres (0,005 – 1,0) mg/l\nStężenie chromu (III) (z obliczeń)\nMetoda spektrofotometryczna PN-EN ISO 18412:2007 | IB-DPA-173 wersja 04 z dnia 02-01-2026 r. Woda Stezenie chromu (VI)\nZakres:\nZakres (0,005 – 1,0) mg/l\nStezenie chromu (III) (z obliczen)\nMetoda spektrofotometryczna PN-EN ISO 18412:2007 | IB-DPA-173 wersja 04 z dnia 02-01-2026 r.","categories":["water"],"row_index":222,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chromium(VI) concentration","parameters_en":[{"name":"Range","range":"(0,005 – 1,0) mg/l"},{"name":"Chromium (III) concentration (calculated)"}],"search_en":"Water Chromium(VI) concentration Spectrophotometric method Range Chromium (III) concentration (calculated) PN-EN ISO 18412:2007 | IB-DPA-173 wersja 04 z dnia 02-01-2026 r.","technique_en":"Spectrophotometric method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,005 – 1,0) mg/l"},{"name":"铬(III)浓度（由计算得出）"}],"search_zh":"水 六价铬浓度 分光光度法 范围 铬(III)浓度（由计算得出） PN-EN ISO 18412:2007 | IB-DPA-173 wersja 04 z dnia 02-01-2026 r.","technique_zh":"分光光度法","test_object_zh":"水","methodology_zh":"六价铬浓度"},{"_id":"6a837a57af14b9c0e7b1fe2c","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Wyciągi wodne z odpadów o) kod: 10 01 01, 10 01 02, 10 01 21, 10 01 24, 10 01 25, 10 01 26, 10 01 80, 10 01 82, 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 05 04, 17 06 04, 17 09 04, 19 09 03, 19 09 04, 20 02 01 przygotowane w Oddziale Analiz, Chemicznych w Elektrowni, Jaworzno (ul. Promienna 51), Popiół, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Żużel, Mieszanka popiołowo - żużlowa","methodology":"Rozpuszczony węgiel organiczny (RWO)","parameters":[{"name":"Zakres","range":"(0,50 – 1000) mg/l"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Rozpuszczony węgiel organiczny (RWO)\nZakres (0,50 – 1000) mg/l\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN 1484:1999","norm_bases":["PN-EN 1484:1999"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Łaziska","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Wyciągi wodne z odpadów o) kod: 10 01 01, 10 01 02, 10 01 21, 10 01 24, 10 01 25, 10 01 26, 10 01 80, 10 01 82, 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 05 04, 17 06 04, 17 09 04, 19 09 03, 19 09 04, 20 02 01 przygotowane w Oddziale Analiz, Chemicznych w Elektrowni, Jaworzno (ul. Promienna 51), Popiół, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Żużel, Mieszanka popiołowo - żużlowa Rozpuszczony węgiel organiczny (RWO)\nZakres (0,50 – 1000) mg/l\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN 1484:1999 Wyciagi wodne z odpadow o) kod: 10 01 01, 10 01 02, 10 01 21, 10 01 24, 10 01 25, 10 01 26, 10 01 80, 10 01 82, 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 05 04, 17 06 04, 17 09 04, 19 09 03, 19 09 04, 20 02 01 przygotowane w Oddziale Analiz, Chemicznych w Elektrowni, Jaworzno (ul. Promienna 51), Popiol, Popiol z produktami odsiarczania - lotny, Popiol z produktami odsiarczania - fluidalny, Piaski ze zloz fluidalnych, Zuzel, Mieszanka popiolowo - zuzlowa Rozpuszczony wegiel organiczny (RWO)\nZakres (0,50 – 1000) mg/l\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN 1484:1999","categories":["environment"],"row_index":223,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissolved organic carbon (DOC)","parameters_en":[{"name":"Range","range":"(0,50 – 1000) mg/l"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Dissolved organic carbon (DOC) High-temperature combustion with IR detection waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Range PN-EN 1484:1999","technique_en":"High-temperature combustion with IR detection","parameters_zh":[{"name":"范围","range":"(0,50 – 1000) mg/l"}],"search_zh":"高温燃烧红外检测法 依据气候部长关于废物目录的条例的废物代码。 范围 PN-EN 1484:1999","technique_zh":"高温燃烧红外检测法","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。"},{"_id":"6a837a57af14b9c0e7b1fe2d","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Wyciągi wodne z odpadów o) kod: 10 01 01, 10 01 02, 10 01 21, 10 01 24, 10 01 25, 10 01 26, 10 01 80, 10 01 82, 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 05 04, 17 06 04, 17 09 04, 19 09 03, 19 09 04, 20 02 01 przygotowane w Oddziale Analiz, Chemicznych w Elektrowni, Jaworzno (ul. Promienna 51), Popiół, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Żużel, Mieszanka popiołowo - żużlowa","methodology":"Stężenie cyjanków wolnych","parameters":[{"name":"Zakres","range":"(0,005 – 1,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie cyjanków wolnych\nZakres (0,005 – 1,00) mg/l\nMetoda spektrofotometryczna","reference":"PN-80/C-04603/01 z wyłączeniem pkt.7 | IB-DPA-18 wersja 03 z dnia 02-01-2026 r.","norm_bases":["PN-80/C-04603/01 z wyłączeniem pkt.7","IB-DPA-18 wersja 03 z dnia 02-01-2026 r."],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Łaziska","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Wyciągi wodne z odpadów o) kod: 10 01 01, 10 01 02, 10 01 21, 10 01 24, 10 01 25, 10 01 26, 10 01 80, 10 01 82, 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 05 04, 17 06 04, 17 09 04, 19 09 03, 19 09 04, 20 02 01 przygotowane w Oddziale Analiz, Chemicznych w Elektrowni, Jaworzno (ul. Promienna 51), Popiół, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Żużel, Mieszanka popiołowo - żużlowa Stężenie cyjanków wolnych\nZakres (0,005 – 1,00) mg/l\nMetoda spektrofotometryczna PN-80/C-04603/01 z wyłączeniem pkt.7 | IB-DPA-18 wersja 03 z dnia 02-01-2026 r. Wyciagi wodne z odpadow o) kod: 10 01 01, 10 01 02, 10 01 21, 10 01 24, 10 01 25, 10 01 26, 10 01 80, 10 01 82, 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 05 04, 17 06 04, 17 09 04, 19 09 03, 19 09 04, 20 02 01 przygotowane w Oddziale Analiz, Chemicznych w Elektrowni, Jaworzno (ul. Promienna 51), Popiol, Popiol z produktami odsiarczania - lotny, Popiol z produktami odsiarczania - fluidalny, Piaski ze zloz fluidalnych, Zuzel, Mieszanka popiolowo - zuzlowa Stezenie cyjankow wolnych\nZakres (0,005 – 1,00) mg/l\nMetoda spektrofotometryczna PN-80/C-04603/01 z wylaczeniem pkt.7 | IB-DPA-18 wersja 03 z dnia 02-01-2026 r.","categories":["environment"],"row_index":224,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free cyanide concentration","parameters_en":[{"name":"Range","range":"(0,005 – 1,00) mg/l"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Free cyanide concentration Spectrophotometric method waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Range PN-80/C-04603/01 z wyłączeniem pkt.7 | IB-DPA-18 wersja 03 z dnia 02-01-2026 r.","technique_en":"Spectrophotometric method","parameters_zh":[{"name":"范围","range":"(0,005 – 1,00) mg/l"}],"search_zh":"游离氰化物浓度 分光光度法 依据气候部长关于废物目录的条例的废物代码。 范围 PN-80/C-04603/01 z wyłączeniem pkt.7 | IB-DPA-18 wersja 03 z dnia 02-01-2026 r.","technique_zh":"分光光度法","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。","methodology_zh":"游离氰化物浓度"},{"_id":"6a837a57af14b9c0e7b1fe2e","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Wyciągi wodne z odpadów o) kod: 10 01 01, 10 01 02, 10 01 21, 10 01 24, 10 01 25, 10 01 26, 10 01 80, 10 01 82, 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 05 04, 17 06 04, 17 09 04, 19 09 03, 19 09 04, 20 02 01 przygotowane w Oddziale Analiz, Chemicznych w Elektrowni, Jaworzno (ul. Promienna 51), Popiół, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Żużel, Mieszanka popiołowo - żużlowa","methodology":"Stężenie siarczków i siarkowodoru","parameters":[{"name":"Zakres","range":"(0,005 – 100,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie siarczków i siarkowodoru\nZakres (0,005 – 100,0) mg/l\nMetoda spektrofotometryczna","reference":"IB-DPA- 92 wersja 04 z dnia 02-01-2026 r. | na podstawie testu HACH nr 8131","norm_bases":["IB-DPA- 92 wersja 04 z dnia 02-01-2026 r.","na podstawie testu HACH nr 8131"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Łaziska","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Wyciągi wodne z odpadów o) kod: 10 01 01, 10 01 02, 10 01 21, 10 01 24, 10 01 25, 10 01 26, 10 01 80, 10 01 82, 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 05 04, 17 06 04, 17 09 04, 19 09 03, 19 09 04, 20 02 01 przygotowane w Oddziale Analiz, Chemicznych w Elektrowni, Jaworzno (ul. Promienna 51), Popiół, Popiół z produktami odsiarczania - lotny, Popiół z produktami odsiarczania - fluidalny, Piaski ze złóż fluidalnych, Żużel, Mieszanka popiołowo - żużlowa Stężenie siarczków i siarkowodoru\nZakres (0,005 – 100,0) mg/l\nMetoda spektrofotometryczna IB-DPA- 92 wersja 04 z dnia 02-01-2026 r. | na podstawie testu HACH nr 8131 Wyciagi wodne z odpadow o) kod: 10 01 01, 10 01 02, 10 01 21, 10 01 24, 10 01 25, 10 01 26, 10 01 80, 10 01 82, 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 05 04, 17 06 04, 17 09 04, 19 09 03, 19 09 04, 20 02 01 przygotowane w Oddziale Analiz, Chemicznych w Elektrowni, Jaworzno (ul. Promienna 51), Popiol, Popiol z produktami odsiarczania - lotny, Popiol z produktami odsiarczania - fluidalny, Piaski ze zloz fluidalnych, Zuzel, Mieszanka popiolowo - zuzlowa Stezenie siarczkow i siarkowodoru\nZakres (0,005 – 100,0) mg/l\nMetoda spektrofotometryczna IB-DPA- 92 wersja 04 z dnia 02-01-2026 r. | na podstawie testu HACH nr 8131","categories":["environment"],"row_index":225,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulphide and hydrogen sulphide concentration","parameters_en":[{"name":"Range","range":"(0,005 – 100,0) mg/l"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Sulphide and hydrogen sulphide concentration Spectrophotometric method waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Range IB-DPA- 92 wersja 04 z dnia 02-01-2026 r. | na podstawie testu HACH nr 8131","technique_en":"Spectrophotometric method","parameters_zh":[{"name":"范围","range":"(0,005 – 100,0) mg/l"}],"search_zh":"硫化物与硫化氢浓度 分光光度法 依据气候部长关于废物目录的条例的废物代码。 范围 IB-DPA- 92 wersja 04 z dnia 02-01-2026 r. | na podstawie testu HACH nr 8131","technique_zh":"分光光度法","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。","methodology_zh":"硫化物与硫化氢浓度"},{"_id":"6a837a57af14b9c0e7b1fe2f","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Wyciągi wodne z materiału budowlanego: kruszywa przygotowane w Oddziale Analiz, Chemicznych w Elektrowni, Jaworzno (ul. Promienna 51)","methodology":"Stężenie cyjanków wolnych","parameters":[{"name":"Zakres","range":"(0,005 – 1,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie cyjanków wolnych\nZakres (0,005 – 1,00) mg/l\nMetoda spektrofotometryczna","reference":"PN-80/C-04603/01 z wyłączeniem pkt.7 | IB-DPA-18 wersja 03 z dnia 02-01-2026 r.","norm_bases":["PN-80/C-04603/01 z wyłączeniem pkt.7","IB-DPA-18 wersja 03 z dnia 02-01-2026 r."],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Łaziska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyciągi wodne z materiału budowlanego: kruszywa przygotowane w Oddziale Analiz, Chemicznych w Elektrowni, Jaworzno (ul. Promienna 51) Stężenie cyjanków wolnych\nZakres (0,005 – 1,00) mg/l\nMetoda spektrofotometryczna PN-80/C-04603/01 z wyłączeniem pkt.7 | IB-DPA-18 wersja 03 z dnia 02-01-2026 r. Wyciagi wodne z materialu budowlanego: kruszywa przygotowane w Oddziale Analiz, Chemicznych w Elektrowni, Jaworzno (ul. Promienna 51) Stezenie cyjankow wolnych\nZakres (0,005 – 1,00) mg/l\nMetoda spektrofotometryczna PN-80/C-04603/01 z wylaczeniem pkt.7 | IB-DPA-18 wersja 03 z dnia 02-01-2026 r.","categories":["materials","construction"],"row_index":226,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free cyanide concentration","parameters_en":[{"name":"Range","range":"(0,005 – 1,00) mg/l"}],"search_en":"Aqueous extracts from construction material: aggregates prepared at Oddział Analiz Chemicznych w Elektrowni Jaworzno (ul. Promienna 51) Free cyanide concentration Spectrophotometric method Range PN-80/C-04603/01 z wyłączeniem pkt.7 | IB-DPA-18 wersja 03 z dnia 02-01-2026 r.","technique_en":"Spectrophotometric method","test_object_en":"Aqueous extracts from construction material: aggregates prepared at Oddział Analiz Chemicznych w Elektrowni Jaworzno (ul. Promienna 51)","parameters_zh":[{"name":"范围","range":"(0,005 – 1,00) mg/l"}],"search_zh":"游离氰化物浓度 分光光度法 范围 PN-80/C-04603/01 z wyłączeniem pkt.7 | IB-DPA-18 wersja 03 z dnia 02-01-2026 r.","technique_zh":"分光光度法","methodology_zh":"游离氰化物浓度"},{"_id":"6a837a57af14b9c0e7b1fe30","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Wyciągi wodne z materiału budowlanego: kruszywa przygotowane w Oddziale Analiz, Chemicznych w Elektrowni, Jaworzno (ul. Promienna 51)","methodology":"Stężenie siarczków i siarkowodoru","parameters":[{"name":"Zakres","range":"(0,005 – 100,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie siarczków i siarkowodoru\nZakres (0,005 – 100,0) mg/l\nMetoda spektrofotometryczna","reference":"IB-DPA- 92 wersja 04 z dnia 02-01-2026 r. | na podstawie testu HACH nr 8131","norm_bases":["IB-DPA- 92 wersja 04 z dnia 02-01-2026 r.","na podstawie testu HACH nr 8131"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Łaziska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyciągi wodne z materiału budowlanego: kruszywa przygotowane w Oddziale Analiz, Chemicznych w Elektrowni, Jaworzno (ul. Promienna 51) Stężenie siarczków i siarkowodoru\nZakres (0,005 – 100,0) mg/l\nMetoda spektrofotometryczna IB-DPA- 92 wersja 04 z dnia 02-01-2026 r. | na podstawie testu HACH nr 8131 Wyciagi wodne z materialu budowlanego: kruszywa przygotowane w Oddziale Analiz, Chemicznych w Elektrowni, Jaworzno (ul. Promienna 51) Stezenie siarczkow i siarkowodoru\nZakres (0,005 – 100,0) mg/l\nMetoda spektrofotometryczna IB-DPA- 92 wersja 04 z dnia 02-01-2026 r. | na podstawie testu HACH nr 8131","categories":["materials","construction"],"row_index":227,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulphide and hydrogen sulphide concentration","parameters_en":[{"name":"Range","range":"(0,005 – 100,0) mg/l"}],"search_en":"Aqueous extracts from construction material: aggregates prepared at Oddział Analiz Chemicznych w Elektrowni Jaworzno (ul. Promienna 51) Sulphide and hydrogen sulphide concentration Spectrophotometric method Range IB-DPA- 92 wersja 04 z dnia 02-01-2026 r. | na podstawie testu HACH nr 8131","technique_en":"Spectrophotometric method","test_object_en":"Aqueous extracts from construction material: aggregates prepared at Oddział Analiz Chemicznych w Elektrowni Jaworzno (ul. Promienna 51)","parameters_zh":[{"name":"范围","range":"(0,005 – 100,0) mg/l"}],"search_zh":"硫化物与硫化氢浓度 分光光度法 范围 IB-DPA- 92 wersja 04 z dnia 02-01-2026 r. | na podstawie testu HACH nr 8131","technique_zh":"分光光度法","methodology_zh":"硫化物与硫化氢浓度"},{"_id":"6a837a57af14b9c0e7b1fe31","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-G-04502:2014-11 pkt 5.3.1.2; 5.3.1.3; 5.3.1.4; 5.3.3; 5.3.4; 5.3.6","norm_bases":["PN-G-04502:2014-11 pkt 5.3.1.2; 5.3.1.3; 5.3.1.4; 5.3.3; 5.3.4; 5.3.6"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Łaziska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Pobieranie próbek do badań chemicznych i fizycznych PN-G-04502:2014-11 pkt 5.3.1.2; 5.3.1.3; 5.3.1.4; 5.3.3; 5.3.4; 5.3.6 Paliwa stale: wegiel kamienny Pobieranie probek do badan chemicznych i fizycznych PN-G-04502:2014-11 pkt 5.3.1.2; 5.3.1.3; 5.3.1.4; 5.3.3; 5.3.4; 5.3.6","categories":["petro"],"row_index":228,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Solid fuels: hard coal Sampling for chemical and physical testing PN-G-04502:2014-11 pkt 5.3.1.2; 5.3.1.3; 5.3.1.4; 5.3.3; 5.3.4; 5.3.6","test_object_en":"Solid fuels: hard coal","methodology_zh":"化学与物理检测用样品采集","search_zh":"固体燃料：烟煤 化学与物理检测用样品采集 PN-G-04502:2014-11 pkt 5.3.1.2; 5.3.1.3; 5.3.1.4; 5.3.3; 5.3.4; 5.3.6","test_object_zh":"固体燃料：烟煤"},{"_id":"6a837a57af14b9c0e7b1fe32","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","methodology":"Zawartość wilgoci w próbce analitycznej","parameters":[{"name":"Zakres","range":"(2,0 – 10,0)%"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (2,0 – 10,0)%\nMetoda wagowa","reference":"PN-EN ISO 18134-3:2023-12","norm_bases":["PN-EN ISO 18134-3:2023-12"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Łaziska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Zawartość wilgoci w próbce analitycznej\nZakres (2,0 – 10,0)%\nMetoda wagowa PN-EN ISO 18134-3:2023-12 Paliwa stale: biomasa stala – biopaliwo stale Zawartosc wilgoci w probce analitycznej\nZakres (2,0 – 10,0)%\nMetoda wagowa PN-EN ISO 18134-3:2023-12","categories":["petro"],"row_index":229,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Moisture content in the analytical sample","parameters_en":[{"name":"Range","range":"(2,0 – 10,0)%"}],"search_en":"Solid fuels: solid biomass – solid biofuel Moisture content in the analytical sample Gravimetric method Range PN-EN ISO 18134-3:2023-12","technique_en":"Gravimetric method","test_object_en":"Solid fuels: solid biomass – solid biofuel","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(2,0 – 10,0)%"}],"search_zh":"固体燃料：固体生物质 – 固体生物燃料 分析样品水分含量 重量法 范围 PN-EN ISO 18134-3:2023-12","technique_zh":"重量法","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料"},{"_id":"6a837a57af14b9c0e7b1fe33","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","methodology":"Zawartość popiołu w próbce analitycznej","parameters":[{"name":"Zakres","range":"(0,5 – 50,0)%"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość popiołu w próbce analitycznej\nZakres (0,5 – 50,0)%\nMetoda wagowa","reference":"PN-EN ISO 18122:2023-05","norm_bases":["PN-EN ISO 18122:2023-05"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Łaziska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Zawartość popiołu w próbce analitycznej\nZakres (0,5 – 50,0)%\nMetoda wagowa PN-EN ISO 18122:2023-05 Paliwa stale: biomasa stala – biopaliwo stale Zawartosc popiolu w probce analitycznej\nZakres (0,5 – 50,0)%\nMetoda wagowa PN-EN ISO 18122:2023-05","categories":["petro"],"row_index":230,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ash content in the analytical sample","parameters_en":[{"name":"Range","range":"(0,5 – 50,0)%"}],"search_en":"Solid fuels: solid biomass – solid biofuel Ash content in the analytical sample Gravimetric method Range PN-EN ISO 18122:2023-05","technique_en":"Gravimetric method","test_object_en":"Solid fuels: solid biomass – solid biofuel","parameters_zh":[{"name":"范围","range":"(0,5 – 50,0)%"}],"search_zh":"固体燃料：固体生物质 – 固体生物燃料 重量法 范围 PN-EN ISO 18122:2023-05","technique_zh":"重量法","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料"},{"_id":"6a837a57af14b9c0e7b1fe34","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","methodology":"Zawartość frakcji biodegradowalnej","parameters":[{"name":"udział masowy biomasy z zastosowaniem selektywnego rozpuszczania"},{"name":"Zakres","range":"(70,0 – 99,5) %"},{"name":"Zawartość frakcji niebiodegradowalnej"},{"name":"udział masowy niebiomasy (z obliczeń)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość frakcji biodegradowalnej\nZakres:\nudział masowy biomasy z zastosowaniem selektywnego rozpuszczania\nZakres (70,0 – 99,5) %\nZawartość frakcji niebiodegradowalnej\nudział masowy niebiomasy (z obliczeń)\nMetoda wagowa","reference":"PN-EN ISO 21644:2021-07, aneks B, pkt. B7","norm_bases":["PN-EN ISO 21644:2021-07, aneks B, pkt. B7"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Łaziska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Zawartość frakcji biodegradowalnej\nZakres:\nudział masowy biomasy z zastosowaniem selektywnego rozpuszczania\nZakres (70,0 – 99,5) %\nZawartość frakcji niebiodegradowalnej\nudział masowy niebiomasy (z obliczeń)\nMetoda wagowa PN-EN ISO 21644:2021-07, aneks B, pkt. B7 Paliwa stale: biomasa stala – biopaliwo stale Zawartosc frakcji biodegradowalnej\nZakres:\nudzial masowy biomasy z zastosowaniem selektywnego rozpuszczania\nZakres (70,0 – 99,5) %\nZawartosc frakcji niebiodegradowalnej\nudzial masowy niebiomasy (z obliczen)\nMetoda wagowa PN-EN ISO 21644:2021-07, aneks B, pkt. B7","categories":["petro"],"row_index":231,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biodegradable fraction content","parameters_en":[{"name":"mass fraction of biomass using selective dissolution"},{"name":"Range","range":"(70,0 – 99,5) %"},{"name":"Content of the non-biodegradable fraction"},{"name":"mass fraction of non-biomass (calculated)"}],"search_en":"Solid fuels: solid biomass – solid biofuel Biodegradable fraction content Gravimetric method mass fraction of biomass using selective dissolution Range Content of the non-biodegradable fraction mass fraction of non-biomass (calculated) PN-EN ISO 21644:2021-07, aneks B, pkt. B7","technique_en":"Gravimetric method","test_object_en":"Solid fuels: solid biomass – solid biofuel","parameters_zh":[{"name":"采用选择性溶解法测定的生物质质量分数"},{"name":"范围","range":"(70,0 – 99,5) %"},{"name":"不可生物降解组分含量"},{"name":"非生物质质量分数（由计算得出）"}],"search_zh":"固体燃料：固体生物质 – 固体生物燃料 可生物降解组分含量 重量法 采用选择性溶解法测定的生物质质量分数 范围 不可生物降解组分含量 非生物质质量分数（由计算得出） PN-EN ISO 21644:2021-07, aneks B, pkt. B7","technique_zh":"重量法","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料","methodology_zh":"可生物降解组分含量"},{"_id":"6a837a57af14b9c0e7b1fe35","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Odpady kod: 10 01 80, Mieszanka popiołowo - żużlowa","methodology":"Strata prażenia","parameters":[{"name":"Zakres","range":"(0,10 – 35,00) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Strata prażenia\nZakres (0,10 – 35,00) %\nMetoda wagowa","reference":"IB-DPA-45 wersja 06 z dnia 02-01-2026 r.","norm_bases":["IB-DPA-45 wersja 06 z dnia 02-01-2026 r."],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Łaziska","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 10 01 80, Mieszanka popiołowo - żużlowa Strata prażenia\nZakres (0,10 – 35,00) %\nMetoda wagowa IB-DPA-45 wersja 06 z dnia 02-01-2026 r. Odpady kod: 10 01 80, Mieszanka popiolowo - zuzlowa Strata prazenia\nZakres (0,10 – 35,00) %\nMetoda wagowa IB-DPA-45 wersja 06 z dnia 02-01-2026 r.","categories":["environment"],"row_index":232,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Loss on ignition","parameters_en":[{"name":"Range","range":"(0,10 – 35,00) %"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Waste code: 10 01 80, Ash - slag mixture Loss on ignition Gravimetric method waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Range IB-DPA-45 wersja 06 z dnia 02-01-2026 r.","technique_en":"Gravimetric method","test_object_en":"Waste code: 10 01 80, Ash - slag mixture","parameters_zh":[{"name":"范围","range":"(0,10 – 35,00) %"}],"search_zh":"烧失量 重量法 依据气候部长关于废物目录的条例的废物代码。 范围 IB-DPA-45 wersja 06 z dnia 02-01-2026 r.","technique_zh":"重量法","methodology_zh":"烧失量","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。"},{"_id":"6a837a57af14b9c0e7b1fe36","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Odpady kod: 10 01 02, 10 01 80, Popiół, Mieszanka popiołowo – żużlowa, Popiół z produktami odsiarczania – lotny, Popiół z produktami odsiarczania - fluidalny","methodology":"Zawartość węgla całkowitego","parameters":[{"name":"Zakres","range":"(0,10 – 35,00)%"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość węgla całkowitego\nZakres (0,10 – 35,00)%\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"IB-DPA-23 wersja 08 z dnia 02-01-2026 r.","norm_bases":["IB-DPA-23 wersja 08 z dnia 02-01-2026 r."],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Łaziska","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 10 01 02, 10 01 80, Popiół, Mieszanka popiołowo – żużlowa, Popiół z produktami odsiarczania – lotny, Popiół z produktami odsiarczania - fluidalny Zawartość węgla całkowitego\nZakres (0,10 – 35,00)%\nMetoda wysokotemperaturowego spalania z detekcją IR IB-DPA-23 wersja 08 z dnia 02-01-2026 r. Odpady kod: 10 01 02, 10 01 80, Popiol, Mieszanka popiolowo – zuzlowa, Popiol z produktami odsiarczania – lotny, Popiol z produktami odsiarczania - fluidalny Zawartosc wegla calkowitego\nZakres (0,10 – 35,00)%\nMetoda wysokotemperaturowego spalania z detekcja IR IB-DPA-23 wersja 08 z dnia 02-01-2026 r.","categories":["environment"],"row_index":233,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total carbon content","parameters_en":[{"name":"Range","range":"(0,10 – 35,00)%"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Total carbon content High-temperature combustion with IR detection waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Range IB-DPA-23 wersja 08 z dnia 02-01-2026 r.","technique_en":"High-temperature combustion with IR detection","methodology_zh":"总碳含量","parameters_zh":[{"name":"范围","range":"(0,10 – 35,00)%"}],"search_zh":"总碳含量 高温燃烧红外检测法 依据气候部长关于废物目录的条例的废物代码。 范围 IB-DPA-23 wersja 08 z dnia 02-01-2026 r.","technique_zh":"高温燃烧红外检测法","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。"},{"_id":"6a837a57af14b9c0e7b1fe37","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Odpady kod: 10 01 02, Materiał budowlany – popiół lotny do betonu, Popiół","methodology":"Miałkość","parameters":[{"name":"Zakres","range":"(10,0 – 50,0)%"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Miałkość\nZakres (10,0 – 50,0)%\nMetoda wagowa","reference":"PN-EN 451-2:2017-06","norm_bases":["PN-EN 451-2:2017-06"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Łaziska","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 10 01 02, Materiał budowlany – popiół lotny do betonu, Popiół Miałkość\nZakres (10,0 – 50,0)%\nMetoda wagowa PN-EN 451-2:2017-06 Odpady kod: 10 01 02, Material budowlany – popiol lotny do betonu, Popiol Mialkosc\nZakres (10,0 – 50,0)%\nMetoda wagowa PN-EN 451-2:2017-06","categories":["construction","environment","materials"],"row_index":234,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fineness","parameters_en":[{"name":"Range","range":"(10,0 – 50,0)%"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Waste code: 10 01 02, Construction material – fly ash for concrete, Ash Fineness Gravimetric method waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Range PN-EN 451-2:2017-06","technique_en":"Gravimetric method","test_object_en":"Waste code: 10 01 02, Construction material – fly ash for concrete, Ash","parameters_zh":[{"name":"范围","range":"(10,0 – 50,0)%"}],"search_zh":"细度 重量法 依据气候部长关于废物目录的条例的废物代码。 范围 PN-EN 451-2:2017-06","technique_zh":"重量法","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。","methodology_zh":"细度"},{"_id":"6a837a57af14b9c0e7b1fe38","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Odpady kod: 10 01 02, 10 01 80, Materiał budowlany – popiół lotny do betonu, Popiół, Mieszanka popiołowo – żużlowa, Popiół z produktami odsiarczania – lotny, Popiół z produktami odsiarczania – fluidalny","methodology":"Straty prażenia","parameters":[{"name":"Zakres","range":"(0,50 – 40,00)%"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Straty prażenia\nZakres (0,50 – 40,00)%\nMetoda wagowa","reference":"PN-EN 196-2:2013-11 | PN-EN 450-1:2012","norm_bases":["PN-EN 196-2:2013-11","PN-EN 450-1:2012"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Łaziska","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 10 01 02, 10 01 80, Materiał budowlany – popiół lotny do betonu, Popiół, Mieszanka popiołowo – żużlowa, Popiół z produktami odsiarczania – lotny, Popiół z produktami odsiarczania – fluidalny Straty prażenia\nZakres (0,50 – 40,00)%\nMetoda wagowa PN-EN 196-2:2013-11 | PN-EN 450-1:2012 Odpady kod: 10 01 02, 10 01 80, Material budowlany – popiol lotny do betonu, Popiol, Mieszanka popiolowo – zuzlowa, Popiol z produktami odsiarczania – lotny, Popiol z produktami odsiarczania – fluidalny Straty prazenia\nZakres (0,50 – 40,00)%\nMetoda wagowa PN-EN 196-2:2013-11 | PN-EN 450-1:2012","categories":["construction","environment","materials"],"row_index":235,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Loss on ignition","parameters_en":[{"name":"Range","range":"(0,50 – 40,00)%"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Loss on ignition Gravimetric method waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Range PN-EN 196-2:2013-11 | PN-EN 450-1:2012","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(0,50 – 40,00)%"}],"search_zh":"烧失量 重量法 依据气候部长关于废物目录的条例的废物代码。 范围 PN-EN 196-2:2013-11 | PN-EN 450-1:2012","technique_zh":"重量法","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。","methodology_zh":"烧失量"},{"_id":"6a837a57af14b9c0e7b1fe39","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Odpady kod: 10 01 02, 10 01 24, Popiół, Popiół z produktami odsiarczania – lotny, Popiół z produktami odsiarczania – fluidalny, Piaski ze złóż fluidalnych","methodology":"Zawartość amoniaku jako NH4","parameters":[{"name":"Zakres","range":"(5,00 – 2000) mg/kg"},{"name":"Zawartość amoniaku jako NH3"},{"name":"Zakres","range":"(4,72 – 1889) mg/kg"}],"technique":"Metoda miareczkowania potencjometrycznego","techniques":["Metoda miareczkowania potencjometrycznego"],"computed":[],"activity":"Zawartość amoniaku jako NH4\nZakres:\nZakres (5,00 – 2000) mg/kg\nZawartość amoniaku jako NH3\nZakres (4,72 – 1889) mg/kg\nMetoda miareczkowania potencjometrycznego","reference":"IB-DPA-74 wersja 04 z dnia 02-01-2026 r.","norm_bases":["IB-DPA-74 wersja 04 z dnia 02-01-2026 r."],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Łaziska","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 10 01 02, 10 01 24, Popiół, Popiół z produktami odsiarczania – lotny, Popiół z produktami odsiarczania – fluidalny, Piaski ze złóż fluidalnych Zawartość amoniaku jako NH4\nZakres:\nZakres (5,00 – 2000) mg/kg\nZawartość amoniaku jako NH3\nZakres (4,72 – 1889) mg/kg\nMetoda miareczkowania potencjometrycznego IB-DPA-74 wersja 04 z dnia 02-01-2026 r. Odpady kod: 10 01 02, 10 01 24, Popiol, Popiol z produktami odsiarczania – lotny, Popiol z produktami odsiarczania – fluidalny, Piaski ze zloz fluidalnych Zawartosc amoniaku jako NH4\nZakres:\nZakres (5,00 – 2000) mg/kg\nZawartosc amoniaku jako NH3\nZakres (4,72 – 1889) mg/kg\nMetoda miareczkowania potencjometrycznego IB-DPA-74 wersja 04 z dnia 02-01-2026 r.","categories":["environment"],"row_index":236,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonia content as NH4","parameters_en":[{"name":"Range","range":"(5,00 – 2000) mg/kg"},{"name":"Ammonia content as NH3"},{"name":"Range","range":"(4,72 – 1889) mg/kg"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue.","search_en":"Ammonia content as NH4 Potentiometric titration method waste codes according to the Regulation of the Minister of Climate on the waste catalogue. Range Ammonia content as NH3 Range IB-DPA-74 wersja 04 z dnia 02-01-2026 r.","technique_en":"Potentiometric titration method","parameters_zh":[{"name":"范围","range":"(5,00 – 2000) mg/kg"},{"name":"Zawartość amoniaku jako NH3"},{"name":"范围","range":"(4,72 – 1889) mg/kg"}],"search_zh":"电位滴定法 依据气候部长关于废物目录的条例的废物代码。 范围 范围 IB-DPA-74 wersja 04 z dnia 02-01-2026 r.","technique_zh":"电位滴定法","regulatory_area_zh":"依据气候部长关于废物目录的条例的废物代码。"},{"_id":"6a837a57af14b9c0e7b1fe3a","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Materiał budowlany: gips","methodology":"Zawartość wilgoci","parameters":[{"name":"Zakres","range":"(2,0 – 25,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci\nZakres (2,0 – 25,0) %\nMetoda wagowa","reference":"IB-DPA-29 wersja 06 z dnia 02-01-2026 r.","norm_bases":["IB-DPA-29 wersja 06 z dnia 02-01-2026 r."],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Łaziska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiał budowlany: gips Zawartość wilgoci\nZakres (2,0 – 25,0) %\nMetoda wagowa IB-DPA-29 wersja 06 z dnia 02-01-2026 r. Material budowlany: gips Zawartosc wilgoci\nZakres (2,0 – 25,0) %\nMetoda wagowa IB-DPA-29 wersja 06 z dnia 02-01-2026 r.","categories":["materials","construction"],"row_index":237,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Moisture content","parameters_en":[{"name":"Range","range":"(2,0 – 25,0) %"}],"search_en":"Construction material: gypsum Moisture content Gravimetric method Range IB-DPA-29 wersja 06 z dnia 02-01-2026 r.","technique_en":"Gravimetric method","test_object_en":"Construction material: gypsum","parameters_zh":[{"name":"范围","range":"(2,0 – 25,0) %"}],"search_zh":"建筑材料：石膏 水分含量 重量法 范围 IB-DPA-29 wersja 06 z dnia 02-01-2026 r.","technique_zh":"重量法","methodology_zh":"水分含量","test_object_zh":"建筑材料：石膏"},{"_id":"6a837a57af14b9c0e7b1fe3b","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Materiał budowlany: gips","methodology":"Zawartość CaSO4 x 2H2O","parameters":[{"name":"Zakres","range":"(50,0 – 99,9) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość CaSO4 x 2H2O\nZakres (50,0 – 99,9) %\nMetoda wagowa","reference":"IB-DPA-30 wersja 06 z dnia 02-01-2026 r.","norm_bases":["IB-DPA-30 wersja 06 z dnia 02-01-2026 r."],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Łaziska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiał budowlany: gips Zawartość CaSO4 x 2H2O\nZakres (50,0 – 99,9) %\nMetoda wagowa IB-DPA-30 wersja 06 z dnia 02-01-2026 r. Material budowlany: gips Zawartosc CaSO4 x 2H2O\nZakres (50,0 – 99,9) %\nMetoda wagowa IB-DPA-30 wersja 06 z dnia 02-01-2026 r.","categories":["materials","construction"],"row_index":238,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"CaSO4 x 2H2O content","parameters_en":[{"name":"Range","range":"(50,0 – 99,9) %"}],"search_en":"Construction material: gypsum CaSO4 x 2H2O content Gravimetric method Range IB-DPA-30 wersja 06 z dnia 02-01-2026 r.","technique_en":"Gravimetric method","test_object_en":"Construction material: gypsum","parameters_zh":[{"name":"范围","range":"(50,0 – 99,9) %"}],"search_zh":"建筑材料：石膏 重量法 范围 IB-DPA-30 wersja 06 z dnia 02-01-2026 r.","technique_zh":"重量法","test_object_zh":"建筑材料：石膏"},{"_id":"6a837a57af14b9c0e7b1fe3c","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Materiał budowlany: gips","methodology":"Zawartość CaCO3","parameters":[{"name":"Zakres","range":"(0,30 – 30,00) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość CaCO3\nZakres (0,30 – 30,00) %\nMetoda miareczkowa","reference":"IB-DPA-31 wersja 06 z dnia 02-01-2026 r.","norm_bases":["IB-DPA-31 wersja 06 z dnia 02-01-2026 r."],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Łaziska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiał budowlany: gips Zawartość CaCO3\nZakres (0,30 – 30,00) %\nMetoda miareczkowa IB-DPA-31 wersja 06 z dnia 02-01-2026 r. Material budowlany: gips Zawartosc CaCO3\nZakres (0,30 – 30,00) %\nMetoda miareczkowa IB-DPA-31 wersja 06 z dnia 02-01-2026 r.","categories":["materials","construction"],"row_index":239,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"CaCO3 content","parameters_en":[{"name":"Range","range":"(0,30 – 30,00) %"}],"search_en":"Construction material: gypsum CaCO3 content Titrimetric method Range IB-DPA-31 wersja 06 z dnia 02-01-2026 r.","technique_en":"Titrimetric method","test_object_en":"Construction material: gypsum","parameters_zh":[{"name":"范围","range":"(0,30 – 30,00) %"}],"search_zh":"建筑材料：石膏 CaCO3 含量 滴定法 范围 IB-DPA-31 wersja 06 z dnia 02-01-2026 r.","technique_zh":"滴定法","test_object_zh":"建筑材料：石膏","methodology_zh":"CaCO3 含量"},{"_id":"6a837a57af14b9c0e7b1fe3d","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Materiał budowlany: gips","methodology":"Zawartość chlorków","parameters":[{"name":"Zakres","range":"(0,0010 – 0,100) %"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość chlorków\nZakres (0,0010 – 0,100) %\nMetoda spektrofotometryczna","reference":"IB-DPA-34 wersja 06 z dnia 02-01-2026 r.","norm_bases":["IB-DPA-34 wersja 06 z dnia 02-01-2026 r."],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Łaziska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiał budowlany: gips Zawartość chlorków\nZakres (0,0010 – 0,100) %\nMetoda spektrofotometryczna IB-DPA-34 wersja 06 z dnia 02-01-2026 r. Material budowlany: gips Zawartosc chlorkow\nZakres (0,0010 – 0,100) %\nMetoda spektrofotometryczna IB-DPA-34 wersja 06 z dnia 02-01-2026 r.","categories":["materials","construction"],"row_index":240,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride content","parameters_en":[{"name":"Range","range":"(0,0010 – 0,100) %"}],"search_en":"Construction material: gypsum Chloride content Spectrophotometric method Range IB-DPA-34 wersja 06 z dnia 02-01-2026 r.","technique_en":"Spectrophotometric method","test_object_en":"Construction material: gypsum","parameters_zh":[{"name":"范围","range":"(0,0010 – 0,100) %"}],"search_zh":"建筑材料：石膏 氯化物含量 分光光度法 范围 IB-DPA-34 wersja 06 z dnia 02-01-2026 r.","technique_zh":"分光光度法","methodology_zh":"氯化物含量","test_object_zh":"建筑材料：石膏"},{"_id":"6a837a57af14b9c0e7b1fe3e","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Materiał budowlany: gips","methodology":"Zawartość krzemionki i części nierozpuszczalnych","parameters":[{"name":"Zakres","range":"(0,20 – 10,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość krzemionki i części nierozpuszczalnych\nZakres (0,20 – 10,0) %\nMetoda wagowa","reference":"IB-DPA-37 wersja 06 z dnia 02-01-2026 r.","norm_bases":["IB-DPA-37 wersja 06 z dnia 02-01-2026 r."],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Łaziska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiał budowlany: gips Zawartość krzemionki i części nierozpuszczalnych\nZakres (0,20 – 10,0) %\nMetoda wagowa IB-DPA-37 wersja 06 z dnia 02-01-2026 r. Material budowlany: gips Zawartosc krzemionki i czesci nierozpuszczalnych\nZakres (0,20 – 10,0) %\nMetoda wagowa IB-DPA-37 wersja 06 z dnia 02-01-2026 r.","categories":["materials","construction"],"row_index":241,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Silica and insoluble matter content","parameters_en":[{"name":"Range","range":"(0,20 – 10,0) %"}],"search_en":"Construction material: gypsum Silica and insoluble matter content Gravimetric method Range IB-DPA-37 wersja 06 z dnia 02-01-2026 r.","technique_en":"Gravimetric method","test_object_en":"Construction material: gypsum","parameters_zh":[{"name":"范围","range":"(0,20 – 10,0) %"}],"search_zh":"建筑材料：石膏 重量法 范围 IB-DPA-37 wersja 06 z dnia 02-01-2026 r.","technique_zh":"重量法","test_object_zh":"建筑材料：石膏"},{"_id":"6a837a57af14b9c0e7b1fe3f","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Materiał budowlany: gips","methodology":"pH wyciągu wodnego","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH wyciągu wodnego\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"IB-DPA-38 wersja 06 z dnia 02-01-2026 r.","norm_bases":["IB-DPA-38 wersja 06 z dnia 02-01-2026 r."],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Łaziska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiał budowlany: gips pH wyciągu wodnego\nZakres 4,0 – 10,0\nMetoda potencjometryczna IB-DPA-38 wersja 06 z dnia 02-01-2026 r. Material budowlany: gips pH wyciagu wodnego\nZakres 4,0 – 10,0\nMetoda potencjometryczna IB-DPA-38 wersja 06 z dnia 02-01-2026 r.","categories":["materials","construction"],"row_index":242,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH of the aqueous extract","parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"search_en":"Construction material: gypsum pH of the aqueous extract Potentiometric method Range IB-DPA-38 wersja 06 z dnia 02-01-2026 r.","technique_en":"Potentiometric method","test_object_en":"Construction material: gypsum","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"建筑材料：石膏 电位法 范围 IB-DPA-38 wersja 06 z dnia 02-01-2026 r.","technique_zh":"电位法","test_object_zh":"建筑材料：石膏"},{"_id":"6a837a57af14b9c0e7b1fe40","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Materiał budowlany: gips","methodology":"Zawartość amoniaku jako NH4","parameters":[{"name":"Zakres","range":"(2,00 – 15,00) mg/kg"},{"name":"Zawartość amoniaku jako NH3"},{"name":"Zakres","range":"(1,89 – 14,17) mg/kg"}],"technique":"Metoda miareczkowania potencjometrycznego","techniques":["Metoda miareczkowania potencjometrycznego"],"computed":[],"activity":"Zawartość amoniaku jako NH4\nZakres:\nZakres (2,00 – 15,00) mg/kg\nZawartość amoniaku jako NH3\nZakres (1,89 – 14,17) mg/kg\nMetoda miareczkowania potencjometrycznego","reference":"IB-DPA-74 wersja 04 z dnia 02-01-2026 r.","norm_bases":["IB-DPA-74 wersja 04 z dnia 02-01-2026 r."],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Łaziska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiał budowlany: gips Zawartość amoniaku jako NH4\nZakres:\nZakres (2,00 – 15,00) mg/kg\nZawartość amoniaku jako NH3\nZakres (1,89 – 14,17) mg/kg\nMetoda miareczkowania potencjometrycznego IB-DPA-74 wersja 04 z dnia 02-01-2026 r. Material budowlany: gips Zawartosc amoniaku jako NH4\nZakres:\nZakres (2,00 – 15,00) mg/kg\nZawartosc amoniaku jako NH3\nZakres (1,89 – 14,17) mg/kg\nMetoda miareczkowania potencjometrycznego IB-DPA-74 wersja 04 z dnia 02-01-2026 r.","categories":["materials","construction"],"row_index":243,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonia content as NH4","parameters_en":[{"name":"Range","range":"(2,00 – 15,00) mg/kg"},{"name":"Ammonia content as NH3"},{"name":"Range","range":"(1,89 – 14,17) mg/kg"}],"search_en":"Construction material: gypsum Ammonia content as NH4 Potentiometric titration method Range Ammonia content as NH3 Range IB-DPA-74 wersja 04 z dnia 02-01-2026 r.","technique_en":"Potentiometric titration method","test_object_en":"Construction material: gypsum","parameters_zh":[{"name":"范围","range":"(2,00 – 15,00) mg/kg"},{"name":"Zawartość amoniaku jako NH3"},{"name":"范围","range":"(1,89 – 14,17) mg/kg"}],"search_zh":"建筑材料：石膏 电位滴定法 范围 范围 IB-DPA-74 wersja 04 z dnia 02-01-2026 r.","technique_zh":"电位滴定法","test_object_zh":"建筑材料：石膏"},{"_id":"6a837a57af14b9c0e7b1fe41","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Wyroby chemiczne: kamień wapienny, w tym sorbenty wapniowe i węglanowe","methodology":"Zawartość wilgoci","parameters":[{"name":"Zakres","range":"(0,10 – 10,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci\nZakres (0,10 – 10,0) %\nMetoda wagowa","reference":"IB-DPA-40 wersja 06 z dnia 02-01-2026 r.","norm_bases":["IB-DPA-40 wersja 06 z dnia 02-01-2026 r."],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Łaziska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby chemiczne: kamień wapienny, w tym sorbenty wapniowe i węglanowe Zawartość wilgoci\nZakres (0,10 – 10,0) %\nMetoda wagowa IB-DPA-40 wersja 06 z dnia 02-01-2026 r. Wyroby chemiczne: kamien wapienny, w tym sorbenty wapniowe i weglanowe Zawartosc wilgoci\nZakres (0,10 – 10,0) %\nMetoda wagowa IB-DPA-40 wersja 06 z dnia 02-01-2026 r.","categories":["other"],"row_index":244,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Moisture content","parameters_en":[{"name":"Range","range":"(0,10 – 10,0) %"}],"search_en":"Chemical products: limestone, including calcium and carbonate sorbents Moisture content Gravimetric method Range IB-DPA-40 wersja 06 z dnia 02-01-2026 r.","technique_en":"Gravimetric method","test_object_en":"Chemical products: limestone, including calcium and carbonate sorbents","parameters_zh":[{"name":"范围","range":"(0,10 – 10,0) %"}],"search_zh":"化工产品：石灰石，含钙质与碳酸盐吸收剂 水分含量 重量法 范围 IB-DPA-40 wersja 06 z dnia 02-01-2026 r.","technique_zh":"重量法","methodology_zh":"水分含量","test_object_zh":"化工产品：石灰石，含钙质与碳酸盐吸收剂"},{"_id":"6a837a57af14b9c0e7b1fe42","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Wyroby chemiczne: kamień wapienny, w tym sorbenty wapniowe i węglanowe","methodology":"Zawartość CaCO3","parameters":[{"name":"Zakres","range":"(50,0 – 99,9) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość CaCO3\nZakres (50,0 – 99,9) %\nMetoda miareczkowa","reference":"IB-DPA-42 wersja 06 z dnia 02-01-2026 r.","norm_bases":["IB-DPA-42 wersja 06 z dnia 02-01-2026 r."],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Łaziska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby chemiczne: kamień wapienny, w tym sorbenty wapniowe i węglanowe Zawartość CaCO3\nZakres (50,0 – 99,9) %\nMetoda miareczkowa IB-DPA-42 wersja 06 z dnia 02-01-2026 r. Wyroby chemiczne: kamien wapienny, w tym sorbenty wapniowe i weglanowe Zawartosc CaCO3\nZakres (50,0 – 99,9) %\nMetoda miareczkowa IB-DPA-42 wersja 06 z dnia 02-01-2026 r.","categories":["other"],"row_index":245,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"CaCO3 content","parameters_en":[{"name":"Range","range":"(50,0 – 99,9) %"}],"search_en":"Chemical products: limestone, including calcium and carbonate sorbents CaCO3 content Titrimetric method Range IB-DPA-42 wersja 06 z dnia 02-01-2026 r.","technique_en":"Titrimetric method","test_object_en":"Chemical products: limestone, including calcium and carbonate sorbents","parameters_zh":[{"name":"范围","range":"(50,0 – 99,9) %"}],"search_zh":"化工产品：石灰石，含钙质与碳酸盐吸收剂 CaCO3 含量 滴定法 范围 IB-DPA-42 wersja 06 z dnia 02-01-2026 r.","technique_zh":"滴定法","test_object_zh":"化工产品：石灰石，含钙质与碳酸盐吸收剂","methodology_zh":"CaCO3 含量"},{"_id":"6a837a57af14b9c0e7b1fe43","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-G-04502:2014-11 pkt 5.3.1.2; 5.3.1.4; 5.3.4","norm_bases":["PN-G-04502:2014-11 pkt 5.3.1.2; 5.3.1.4; 5.3.4"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Łagisza","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Pobieranie próbek do badań chemicznych i fizycznych PN-G-04502:2014-11 pkt 5.3.1.2; 5.3.1.4; 5.3.4 Paliwa stale: wegiel kamienny Pobieranie probek do badan chemicznych i fizycznych PN-G-04502:2014-11 pkt 5.3.1.2; 5.3.1.4; 5.3.4","categories":["petro"],"row_index":246,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Solid fuels: hard coal Sampling for chemical and physical testing PN-G-04502:2014-11 pkt 5.3.1.2; 5.3.1.4; 5.3.4","test_object_en":"Solid fuels: hard coal","methodology_zh":"化学与物理检测用样品采集","search_zh":"固体燃料：烟煤 化学与物理检测用样品采集 PN-G-04502:2014-11 pkt 5.3.1.2; 5.3.1.4; 5.3.4","test_object_zh":"固体燃料：烟煤"},{"_id":"6a837a57af14b9c0e7b1fe44","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-G-04502:2014-11pkt 5.3.3, 5.3.4; 5.3.6","norm_bases":["PN-G-04502:2014-11pkt 5.3.3, 5.3.4; 5.3.6"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Siersza","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Pobieranie próbek do badań chemicznych i fizycznych PN-G-04502:2014-11pkt 5.3.3, 5.3.4; 5.3.6 Paliwa stale: wegiel kamienny Pobieranie probek do badan chemicznych i fizycznych PN-G-04502:2014-11pkt 5.3.3, 5.3.4; 5.3.6","categories":["petro"],"row_index":247,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Solid fuels: hard coal Sampling for chemical and physical testing PN-G-04502:2014-11pkt 5.3.3, 5.3.4; 5.3.6","test_object_en":"Solid fuels: hard coal","methodology_zh":"化学与物理检测用样品采集","search_zh":"固体燃料：烟煤 化学与物理检测用样品采集 PN-G-04502:2014-11pkt 5.3.3, 5.3.4; 5.3.6","test_object_zh":"固体燃料：烟煤"},{"_id":"6a837a57af14b9c0e7b1fe45","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-EN ISO 18135:2017-06 z wyłączeniem pkt. 11.3, 12.3, 12.4","norm_bases":["PN-EN ISO 18135:2017-06 z wyłączeniem pkt. 11.3, 12.3, 12.4"],"lab_section":"Oddział Analiz Chemicznych w Elektrowni Siersza","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Pobieranie próbek do badań chemicznych i fizycznych PN-EN ISO 18135:2017-06 z wyłączeniem pkt. 11.3, 12.3, 12.4 Paliwa stale: biomasa stala – biopaliwo stale Pobieranie probek do badan chemicznych i fizycznych PN-EN ISO 18135:2017-06 z wylaczeniem pkt. 11.3, 12.3, 12.4","categories":["petro"],"row_index":248,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Solid fuels: solid biomass – solid biofuel Sampling for chemical and physical testing PN-EN ISO 18135:2017-06 z wyłączeniem pkt. 11.3, 12.3, 12.4","test_object_en":"Solid fuels: solid biomass – solid biofuel","methodology_zh":"化学与物理检测用样品采集","search_zh":"固体燃料：固体生物质 – 固体生物燃料 化学与物理检测用样品采集 PN-EN ISO 18135:2017-06 z wyłączeniem pkt. 11.3, 12.3, 12.4","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料"},{"_id":"6a837a57af14b9c0e7b1fe46","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-G-04502:2014-11 pkt 5.3.1.3; 5.3.1.4; 5.3.4","norm_bases":["PN-G-04502:2014-11 pkt 5.3.1.3; 5.3.1.4; 5.3.4"],"lab_section":"Oddział Analiz Chemicznych w Elektrociepłowni Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Pobieranie próbek do badań chemicznych i fizycznych PN-G-04502:2014-11 pkt 5.3.1.3; 5.3.1.4; 5.3.4 Paliwa stale: wegiel kamienny Pobieranie probek do badan chemicznych i fizycznych PN-G-04502:2014-11 pkt 5.3.1.3; 5.3.1.4; 5.3.4","categories":["petro"],"row_index":249,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Solid fuels: hard coal Sampling for chemical and physical testing PN-G-04502:2014-11 pkt 5.3.1.3; 5.3.1.4; 5.3.4","test_object_en":"Solid fuels: hard coal","methodology_zh":"化学与物理检测用样品采集","search_zh":"固体燃料：烟煤 化学与物理检测用样品采集 PN-G-04502:2014-11 pkt 5.3.1.3; 5.3.1.4; 5.3.4","test_object_zh":"固体燃料：烟煤"},{"_id":"6a837a57af14b9c0e7b1fe47","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-G-04502:2014-11 pkt 5.3.1.3; 5.3.3; 5.3.4","norm_bases":["PN-G-04502:2014-11 pkt 5.3.1.3; 5.3.3; 5.3.4"],"lab_section":"Oddział Analiz Chemicznych w Elektrociepłowni Tychy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Pobieranie próbek do badań chemicznych i fizycznych PN-G-04502:2014-11 pkt 5.3.1.3; 5.3.3; 5.3.4 Paliwa stale: wegiel kamienny Pobieranie probek do badan chemicznych i fizycznych PN-G-04502:2014-11 pkt 5.3.1.3; 5.3.3; 5.3.4","categories":["petro"],"row_index":250,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Solid fuels: hard coal Sampling for chemical and physical testing PN-G-04502:2014-11 pkt 5.3.1.3; 5.3.3; 5.3.4","test_object_en":"Solid fuels: hard coal","methodology_zh":"化学与物理检测用样品采集","search_zh":"固体燃料：烟煤 化学与物理检测用样品采集 PN-G-04502:2014-11 pkt 5.3.1.3; 5.3.3; 5.3.4","test_object_zh":"固体燃料：烟煤"},{"_id":"6a837a57af14b9c0e7b1fe48","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-EN ISO 18135:2017-06 z wyłączeniem pkt 12.4","norm_bases":["PN-EN ISO 18135:2017-06 z wyłączeniem pkt 12.4"],"lab_section":"Oddział Analiz Chemicznych w Elektrociepłowni Tychy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Pobieranie próbek do badań chemicznych i fizycznych PN-EN ISO 18135:2017-06 z wyłączeniem pkt 12.4 Paliwa stale: biomasa stala – biopaliwo stale Pobieranie probek do badan chemicznych i fizycznych PN-EN ISO 18135:2017-06 z wylaczeniem pkt 12.4","categories":["petro"],"row_index":251,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Solid fuels: solid biomass – solid biofuel Sampling for chemical and physical testing PN-EN ISO 18135:2017-06 z wyłączeniem pkt 12.4","test_object_en":"Solid fuels: solid biomass – solid biofuel","methodology_zh":"化学与物理检测用样品采集","search_zh":"固体燃料：固体生物质 – 固体生物燃料 化学与物理检测用样品采集 PN-EN ISO 18135:2017-06 z wyłączeniem pkt 12.4","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料"},{"_id":"6a837a57af14b9c0e7b1fe49","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-G-04502:2014-11 pkt 5.3.1.2; 5.3.1.3","norm_bases":["PN-G-04502:2014-11 pkt 5.3.1.2; 5.3.1.3"],"lab_section":"Oddział Analiz Chemicznych w Elektrociepłowni Bielsko - Biała","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Pobieranie próbek do badań chemicznych i fizycznych PN-G-04502:2014-11 pkt 5.3.1.2; 5.3.1.3 Paliwa stale: wegiel kamienny Pobieranie probek do badan chemicznych i fizycznych PN-G-04502:2014-11 pkt 5.3.1.2; 5.3.1.3","categories":["petro"],"row_index":252,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Solid fuels: hard coal Sampling for chemical and physical testing PN-G-04502:2014-11 pkt 5.3.1.2; 5.3.1.3","test_object_en":"Solid fuels: hard coal","methodology_zh":"化学与物理检测用样品采集","search_zh":"固体燃料：烟煤 化学与物理检测用样品采集 PN-G-04502:2014-11 pkt 5.3.1.2; 5.3.1.3","test_object_zh":"固体燃料：烟煤"},{"_id":"6a837a57af14b9c0e7b1fe4a","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-G-04502:2014-11 pkt 5.3.1.2; 5.3.1.3; 5.3.3","norm_bases":["PN-G-04502:2014-11 pkt 5.3.1.2; 5.3.1.3; 5.3.3"],"lab_section":"Oddział Analiz Chemicznych w Elektrociepłowni Bielsko - Biała","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Pobieranie próbek do badań chemicznych i fizycznych PN-G-04502:2014-11 pkt 5.3.1.2; 5.3.1.3; 5.3.3 Paliwa stale: wegiel kamienny Pobieranie probek do badan chemicznych i fizycznych PN-G-04502:2014-11 pkt 5.3.1.2; 5.3.1.3; 5.3.3","categories":["petro"],"row_index":253,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Solid fuels: hard coal Sampling for chemical and physical testing PN-G-04502:2014-11 pkt 5.3.1.2; 5.3.1.3; 5.3.3","test_object_en":"Solid fuels: hard coal","methodology_zh":"化学与物理检测用样品采集","search_zh":"固体燃料：烟煤 化学与物理检测用样品采集 PN-G-04502:2014-11 pkt 5.3.1.2; 5.3.1.3; 5.3.3","test_object_zh":"固体燃料：烟煤"},{"_id":"6a837a57af14b9c0e7b1fe4b","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-G-04502:2014-11 pkt 5.3.1.2; 5.3.1.3; 5.3.6","norm_bases":["PN-G-04502:2014-11 pkt 5.3.1.2; 5.3.1.3; 5.3.6"],"lab_section":"Oddział Analiz Chemicznych w Zakładzie Górniczym Sobieski","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Pobieranie próbek do badań chemicznych i fizycznych PN-G-04502:2014-11 pkt 5.3.1.2; 5.3.1.3; 5.3.6 Paliwa stale: wegiel kamienny Pobieranie probek do badan chemicznych i fizycznych PN-G-04502:2014-11 pkt 5.3.1.2; 5.3.1.3; 5.3.6","categories":["petro"],"row_index":254,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Solid fuels: hard coal Sampling for chemical and physical testing PN-G-04502:2014-11 pkt 5.3.1.2; 5.3.1.3; 5.3.6","test_object_en":"Solid fuels: hard coal","methodology_zh":"化学与物理检测用样品采集","search_zh":"固体燃料：烟煤 化学与物理检测用样品采集 PN-G-04502:2014-11 pkt 5.3.1.2; 5.3.1.3; 5.3.6","test_object_zh":"固体燃料：烟煤"},{"_id":"6a837a57af14b9c0e7b1fe4c","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Gęstość nasypowa","parameters":[{"name":"Zakres","range":"(0,70 -1,25) Mg/m3"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Gęstość nasypowa\nZakres (0,70 -1,25) Mg/m3\nMetoda wagowa","reference":"PN-73/G-04531 pkt 2.4 | IB-DPA-175 wersja 03 z dnia 02-01-2026 r.","norm_bases":["PN-73/G-04531 pkt 2.4","IB-DPA-175 wersja 03 z dnia 02-01-2026 r."],"lab_section":"Oddział Analiz Chemicznych w Zakładzie Górniczym Sobieski","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Gęstość nasypowa\nZakres (0,70 -1,25) Mg/m3\nMetoda wagowa PN-73/G-04531 pkt 2.4 | IB-DPA-175 wersja 03 z dnia 02-01-2026 r. Paliwa stale: wegiel kamienny Gestosc nasypowa\nZakres (0,70 -1,25) Mg/m3\nMetoda wagowa PN-73/G-04531 pkt 2.4 | IB-DPA-175 wersja 03 z dnia 02-01-2026 r.","categories":["petro"],"row_index":255,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Bulk density","parameters_en":[{"name":"Range","range":"(0,70 -1,25) Mg/m3"}],"search_en":"Solid fuels: hard coal Bulk density Gravimetric method Range PN-73/G-04531 pkt 2.4 | IB-DPA-175 wersja 03 z dnia 02-01-2026 r.","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","parameters_zh":[{"name":"范围","range":"(0,70 -1,25) Mg/m3"}],"search_zh":"固体燃料：烟煤 堆积密度 重量法 范围 PN-73/G-04531 pkt 2.4 | IB-DPA-175 wersja 03 z dnia 02-01-2026 r.","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤","methodology_zh":"堆积密度"},{"_id":"6a837a57af14b9c0e7b1fe4d","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Ciężar objętościowy","parameters":[{"name":"Zakres","range":"(0,70 - 1,50) Mg/m3"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Ciężar objętościowy\nZakres (0,70 - 1,50) Mg/m3\nMetoda wagowa","reference":"IB-DPA-175 wersja 03 z dnia 02-01-2026 r.","norm_bases":["IB-DPA-175 wersja 03 z dnia 02-01-2026 r."],"lab_section":"Oddział Analiz Chemicznych w Zakładzie Górniczym Sobieski","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Ciężar objętościowy\nZakres (0,70 - 1,50) Mg/m3\nMetoda wagowa IB-DPA-175 wersja 03 z dnia 02-01-2026 r. Paliwa stale: wegiel kamienny Ciezar objetosciowy\nZakres (0,70 - 1,50) Mg/m3\nMetoda wagowa IB-DPA-175 wersja 03 z dnia 02-01-2026 r.","categories":["petro"],"row_index":256,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Unit weight","parameters_en":[{"name":"Range","range":"(0,70 - 1,50) Mg/m3"}],"search_en":"Solid fuels: hard coal Unit weight Gravimetric method Range IB-DPA-175 wersja 03 z dnia 02-01-2026 r.","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","parameters_zh":[{"name":"范围","range":"(0,70 - 1,50) Mg/m3"}],"search_zh":"固体燃料：烟煤 重量法 范围 IB-DPA-175 wersja 03 z dnia 02-01-2026 r.","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a837a57af14b9c0e7b1fe4e","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-G-04502:2014-11 pkt 5.3.1.2; 5.3.1.4; 5.3.6","norm_bases":["PN-G-04502:2014-11 pkt 5.3.1.2; 5.3.1.4; 5.3.6"],"lab_section":"Oddział Analiz Chemicznych w Zakładzie Górniczym Janina","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Pobieranie próbek do badań chemicznych i fizycznych PN-G-04502:2014-11 pkt 5.3.1.2; 5.3.1.4; 5.3.6 Paliwa stale: wegiel kamienny Pobieranie probek do badan chemicznych i fizycznych PN-G-04502:2014-11 pkt 5.3.1.2; 5.3.1.4; 5.3.6","categories":["petro"],"row_index":257,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Solid fuels: hard coal Sampling for chemical and physical testing PN-G-04502:2014-11 pkt 5.3.1.2; 5.3.1.4; 5.3.6","test_object_en":"Solid fuels: hard coal","methodology_zh":"化学与物理检测用样品采集","search_zh":"固体燃料：烟煤 化学与物理检测用样品采集 PN-G-04502:2014-11 pkt 5.3.1.2; 5.3.1.4; 5.3.6","test_object_zh":"固体燃料：烟煤"},{"_id":"6a837a57af14b9c0e7b1fe4f","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Gęstość nasypowa","parameters":[{"name":"Zakres","range":"(0,80 - 1,25) Mg/m3"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Gęstość nasypowa\nZakres (0,80 - 1,25) Mg/m3\nMetoda wagowa","reference":"PN-73/G-04531 pkt 2.4 | IB-DPA-175 wersja 03 z dnia 02-01-2026 r.","norm_bases":["PN-73/G-04531 pkt 2.4","IB-DPA-175 wersja 03 z dnia 02-01-2026 r."],"lab_section":"Oddział Analiz Chemicznych w Zakładzie Górniczym Janina","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Gęstość nasypowa\nZakres (0,80 - 1,25) Mg/m3\nMetoda wagowa PN-73/G-04531 pkt 2.4 | IB-DPA-175 wersja 03 z dnia 02-01-2026 r. Paliwa stale: wegiel kamienny Gestosc nasypowa\nZakres (0,80 - 1,25) Mg/m3\nMetoda wagowa PN-73/G-04531 pkt 2.4 | IB-DPA-175 wersja 03 z dnia 02-01-2026 r.","categories":["petro"],"row_index":258,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Bulk density","parameters_en":[{"name":"Range","range":"(0,80 - 1,25) Mg/m3"}],"search_en":"Solid fuels: hard coal Bulk density Gravimetric method Range PN-73/G-04531 pkt 2.4 | IB-DPA-175 wersja 03 z dnia 02-01-2026 r.","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","parameters_zh":[{"name":"范围","range":"(0,80 - 1,25) Mg/m3"}],"search_zh":"固体燃料：烟煤 堆积密度 重量法 范围 PN-73/G-04531 pkt 2.4 | IB-DPA-175 wersja 03 z dnia 02-01-2026 r.","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤","methodology_zh":"堆积密度"},{"_id":"6a837a57af14b9c0e7b1fe50","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Ciężar objętościowy","parameters":[{"name":"Zakres","range":"(0,90 - 1,50) Mg/m3"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Ciężar objętościowy\nZakres (0,90 - 1,50) Mg/m3\nMetoda wagowa","reference":"IB-DPA-175 wersja 03 z dnia 02-01-2026 r.","norm_bases":["IB-DPA-175 wersja 03 z dnia 02-01-2026 r."],"lab_section":"Oddział Analiz Chemicznych w Zakładzie Górniczym Janina","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Ciężar objętościowy\nZakres (0,90 - 1,50) Mg/m3\nMetoda wagowa IB-DPA-175 wersja 03 z dnia 02-01-2026 r. Paliwa stale: wegiel kamienny Ciezar objetosciowy\nZakres (0,90 - 1,50) Mg/m3\nMetoda wagowa IB-DPA-175 wersja 03 z dnia 02-01-2026 r.","categories":["petro"],"row_index":259,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Unit weight","parameters_en":[{"name":"Range","range":"(0,90 - 1,50) Mg/m3"}],"search_en":"Solid fuels: hard coal Unit weight Gravimetric method Range IB-DPA-175 wersja 03 z dnia 02-01-2026 r.","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","parameters_zh":[{"name":"范围","range":"(0,90 - 1,50) Mg/m3"}],"search_zh":"固体燃料：烟煤 重量法 范围 IB-DPA-175 wersja 03 z dnia 02-01-2026 r.","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a837a57af14b9c0e7b1fe51","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-G-04502:2014-11 pkt 5.3.1.2; 5.3.1.3; 5.3.6","norm_bases":["PN-G-04502:2014-11 pkt 5.3.1.2; 5.3.1.3; 5.3.6"],"lab_section":"Oddział Analiz Chemicznych w Zakładzie Górniczym Brzeszcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Pobieranie próbek do badań chemicznych i fizycznych PN-G-04502:2014-11 pkt 5.3.1.2; 5.3.1.3; 5.3.6 Paliwa stale: wegiel kamienny Pobieranie probek do badan chemicznych i fizycznych PN-G-04502:2014-11 pkt 5.3.1.2; 5.3.1.3; 5.3.6","categories":["petro"],"row_index":260,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Solid fuels: hard coal Sampling for chemical and physical testing PN-G-04502:2014-11 pkt 5.3.1.2; 5.3.1.3; 5.3.6","test_object_en":"Solid fuels: hard coal","methodology_zh":"化学与物理检测用样品采集","search_zh":"固体燃料：烟煤 化学与物理检测用样品采集 PN-G-04502:2014-11 pkt 5.3.1.2; 5.3.1.3; 5.3.6","test_object_zh":"固体燃料：烟煤"},{"_id":"6a837a57af14b9c0e7b1fe52","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Gęstość nasypowa","parameters":[{"name":"Zakres","range":"(0,70 - 0,90) Mg/m3"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Gęstość nasypowa\nZakres (0,70 - 0,90) Mg/m3\nMetoda wagowa","reference":"PN-73/G-04531 pkt 2.4 | IB-DPA-175 wersja 03 z dnia 02-01-2026 r.","norm_bases":["PN-73/G-04531 pkt 2.4","IB-DPA-175 wersja 03 z dnia 02-01-2026 r."],"lab_section":"Oddział Analiz Chemicznych w Zakładzie Górniczym Brzeszcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Gęstość nasypowa\nZakres (0,70 - 0,90) Mg/m3\nMetoda wagowa PN-73/G-04531 pkt 2.4 | IB-DPA-175 wersja 03 z dnia 02-01-2026 r. Paliwa stale: wegiel kamienny Gestosc nasypowa\nZakres (0,70 - 0,90) Mg/m3\nMetoda wagowa PN-73/G-04531 pkt 2.4 | IB-DPA-175 wersja 03 z dnia 02-01-2026 r.","categories":["petro"],"row_index":261,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Bulk density","parameters_en":[{"name":"Range","range":"(0,70 - 0,90) Mg/m3"}],"search_en":"Solid fuels: hard coal Bulk density Gravimetric method Range PN-73/G-04531 pkt 2.4 | IB-DPA-175 wersja 03 z dnia 02-01-2026 r.","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","parameters_zh":[{"name":"范围","range":"(0,70 - 0,90) Mg/m3"}],"search_zh":"固体燃料：烟煤 堆积密度 重量法 范围 PN-73/G-04531 pkt 2.4 | IB-DPA-175 wersja 03 z dnia 02-01-2026 r.","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤","methodology_zh":"堆积密度"},{"_id":"6a837a57af14b9c0e7b1fe53","lab_id":"69ad52a3de79e566650fb380","country":"PL","accr_number":"AB 688","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Ciężar objętościowy","parameters":[{"name":"Zakres","range":"(0,80 - 1,60) Mg/m3"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Ciężar objętościowy\nZakres (0,80 - 1,60) Mg/m3\nMetoda wagowa","reference":"IB-DPA-175 wersja 03 z dnia 02-01-2026 r.","norm_bases":["IB-DPA-175 wersja 03 z dnia 02-01-2026 r."],"lab_section":"Oddział Analiz Chemicznych w Zakładzie Górniczym Brzeszcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Ciężar objętościowy\nZakres (0,80 - 1,60) Mg/m3\nMetoda wagowa IB-DPA-175 wersja 03 z dnia 02-01-2026 r. Paliwa stale: wegiel kamienny Ciezar objetosciowy\nZakres (0,80 - 1,60) Mg/m3\nMetoda wagowa IB-DPA-175 wersja 03 z dnia 02-01-2026 r.","categories":["petro"],"row_index":262,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Unit weight","parameters_en":[{"name":"Range","range":"(0,80 - 1,60) Mg/m3"}],"search_en":"Solid fuels: hard coal Unit weight Gravimetric method Range IB-DPA-175 wersja 03 z dnia 02-01-2026 r.","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","parameters_zh":[{"name":"范围","range":"(0,80 - 1,60) Mg/m3"}],"search_zh":"固体燃料：烟煤 重量法 范围 IB-DPA-175 wersja 03 z dnia 02-01-2026 r.","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤"}],"has_pdf":true}