{"lab":{"_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","address":"LABORATORIUM BADAWCZO-ROZWOJOWE, ul. Ujastek 1, 31-752 Kraków","categories":["construction","petro","materials","environment","water"],"city":"Kraków","imported_at":"2026-03-08T10:42:43.265Z","methods_count":180,"name":"FERROCARBO Sp. z o.o.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_687.pdf"],"scope_summary":"","search_text":"ferrocarbo sp. z o.o. laboratorium badawczo-rozwojowe, ul. ujastek 1, 31-752 kraków materials other environment construction electronics petro water pharma food","status":"active","updated_at":"2026-03-08T14:51:35.262Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:35.262Z","location":{"type":"Point","coordinates":[19.945,50.0647]},"email_confidence":"high","email_mx":true,"email_source":"https://ferrocarbo.pl/en/contact/","fields_of_testing":[{"codes":"C/5/P; C/10/P; C/12/P; C/32/P","pl":"Badania chemiczne i pobieranie próbek wyrobów budowlanych, materiałów budowlanych, paliw, szkła i ceramiki, odpadów","en":"Chemical tests and sampling of building products, building materials, fuels, glass and ceramics, waste"},{"codes":"C/5; C/8; C/10; C/12; C/32","pl":"Badania chemiczne wyrobów budowlanych, materiałów budowlanych, materiałów konstrukcyjnych, paliw, szkła i ceramiki, odpadów","en":"Chemical tests of building products, building materials, construction materials, fuels, glass and ceramics, waste"},{"codes":"J/5/P; J/12/P","pl":"Badania mechaniczne i pobieranie próbek wyrobów budowlanych, materiałów budowlanych, szkła i ceramiki","en":"Mechanical tests and sampling of building products, building materials, glass and ceramics"},{"codes":"N/5/P; N/10/P; N/12/P; N/32/P","pl":"Badania właściwości fizycznych i pobieranie próbek wyrobów budowlanych, materiałów budowlanych, paliw, szkła i ceramiki, odpadów","en":"Tests of physical properties and sampling of building products, building materials, fuels, glass and ceramics, waste"},{"codes":"N/5; N/10; N/12; N/32","pl":"Badania właściwości fizycznych wyrobów budowlanych, materiałów budowlanych, paliw, szkła i ceramiki, odpadów","en":"Tests of physical properties of building products, building materials, fuels, glass and ceramics, waste"},{"codes":"O/5/P","pl":"Badania promieniowania i pobieranie próbek wyrobów budowlanych, materiałów budowlanych","en":"tests of radiation and sampling of building products, building materials"},{"codes":"O/5; O/32","pl":"Badania promieniowania wyrobów budowlanych, materiałów budowlanych i odpadów","en":"tests of radiation of building products, building materials and waste"}],"issue":{"no":"22","date":"26.01.2026"},"parse_date":"2026-07-20T07:09:47.591Z","parse_source":"script-pdfplumber","map_coord":[50.07867,20.090219],"map_geo":"nominatim-street","has_en":true,"category_counts":{"other":85,"construction":38,"petro":36,"materials":32,"environment":23,"water":8},"category_scores":{"other":32.55,"construction":6.5,"petro":5.84,"materials":4.61,"environment":2.38,"water":0.29},"has_zh":true},"methods":[{"_id":"6a5dc9bbf1c10c8ce825dfcc","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Wyroby i materiały ogniotrwałe, żużle, surowce, wyroby ceramiczne","test_object_en":"Refractory products and materials, slags, raw materials, ceramic products","methodology":"Strata prażenia","methodology_en":"Loss on ignition","parameters":[{"name":"Zakres","range":"(0,05 – 97,0) %"}],"parameters_en":[{"name":"Range","range":"(0,05 – 97,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Strata prażenia\nZakres (0,05 – 97,0) %\nMetoda wagowa","reference":"PN-EN ISO 26845:2009","norm_bases":["PN-EN ISO 26845:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby i materiały ogniotrwałe, żużle, surowce, wyroby ceramiczne Strata prażenia\nZakres (0,05 – 97,0) %\nMetoda wagowa PN-EN ISO 26845:2009 Wyroby i materialy ogniotrwale, zuzle, surowce, wyroby ceramiczne Strata prazenia\nZakres (0,05 – 97,0) %\nMetoda wagowa PN-EN ISO 26845:2009","categories":["materials"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Refractory products and materials, slags, raw materials, ceramic products Loss on ignition Gravimetric method Range PN-EN ISO 26845:2009","parameters_zh":[{"name":"范围","range":"(0,05 – 97,0) %"}],"search_zh":"烧失量 重量法 范围 PN-EN ISO 26845:2009","technique_zh":"重量法","methodology_zh":"烧失量"},{"_id":"6a5dc9bbf1c10c8ce825dfcd","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Wyroby i materiały ogniotrwałe, żużle, surowce, wyroby ceramiczne","test_object_en":"Refractory products and materials, slags, raw materials, ceramic products","methodology":"Zawartość SiO2, Fe2O3, Al2O3, TiO2, CaO, MgO, K2O, Na2O, MnO, Cr2O3, P2O5, SO3, ZrO2","methodology_en":"Content of SiO2, Fe2O3, Al2O3, TiO2, CaO, MgO, K2O, Na2O, MnO, Cr2O3, P2O5, SO3, ZrO2","parameters":[{"name":"SiO2","range":"(0,10 – 99,9) %"},{"name":"Fe2O3","range":"(0,10 – 99,8) %"},{"name":"Al2O3","range":"(0,10 – 99,9) %"},{"name":"TiO2","range":"(0,10 – 3,60) %"},{"name":"CaO","range":"(0,10 – 98,0) %"},{"name":"MgO","range":"(0,10 – 98,5) %"},{"name":"K2O","range":"(0,10 – 11,0) %"},{"name":"Na2O","range":"(0,10 – 7,50) %"},{"name":"MnO","range":"(0,10 – 4,50) %"},{"name":"Cr2O3","range":"(0,10 – 42,0) %"},{"name":"P2O5","range":"(0,10 – 31,0) %"},{"name":"SO3","range":"(0,10 – 11,0) %"},{"name":"ZrO2","range":"(0,10 – 94,0) %"}],"parameters_en":[{"name":"SiO2","range":"(0,10 – 99,9) %"},{"name":"Fe2O3","range":"(0,10 – 99,8) %"},{"name":"Al2O3","range":"(0,10 – 99,9) %"},{"name":"TiO2","range":"(0,10 – 3,60) %"},{"name":"CaO","range":"(0,10 – 98,0) %"},{"name":"MgO","range":"(0,10 – 98,5) %"},{"name":"K2O","range":"(0,10 – 11,0) %"},{"name":"Na2O","range":"(0,10 – 7,50) %"},{"name":"MnO","range":"(0,10 – 4,50) %"},{"name":"Cr2O3","range":"(0,10 – 42,0) %"},{"name":"P2O5","range":"(0,10 – 31,0) %"},{"name":"SO3","range":"(0,10 – 11,0) %"},{"name":"ZrO2","range":"(0,10 – 94,0) %"}],"technique":"Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF)","techniques":["Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF)"],"technique_en":"Wavelength dispersive X-ray fluorescence spectrometry (WD-XRF)","computed":[],"computed_en":[],"activity":"Zawartość SiO2, Fe2O3, Al2O3, TiO2, CaO, MgO, K2O, Na2O, MnO, Cr2O3, P2O5, SO3, ZrO2\nZakres:\nSiO2 (0,10 – 99,9) %\nFe2O3 (0,10 – 99,8) %\nAl2O3 (0,10 – 99,9) %\nTiO2 (0,10 – 3,60) %\nCaO (0,10 – 98,0) %\nMgO (0,10 – 98,5) %\nK2O (0,10 – 11,0) %\nNa2O (0,10 – 7,50) %\nMnO (0,10 – 4,50) %\nCr2O3 (0,10 – 42,0) %\nP2O5 (0,10 – 31,0) %\nSO3 (0,10 – 11,0) %\nZrO2 (0,10 – 94,0) %\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF)","reference":"PN-EN ISO 12677:2011","norm_bases":["PN-EN ISO 12677:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby i materiały ogniotrwałe, żużle, surowce, wyroby ceramiczne Zawartość SiO2, Fe2O3, Al2O3, TiO2, CaO, MgO, K2O, Na2O, MnO, Cr2O3, P2O5, SO3, ZrO2\nZakres:\nSiO2 (0,10 – 99,9) %\nFe2O3 (0,10 – 99,8) %\nAl2O3 (0,10 – 99,9) %\nTiO2 (0,10 – 3,60) %\nCaO (0,10 – 98,0) %\nMgO (0,10 – 98,5) %\nK2O (0,10 – 11,0) %\nNa2O (0,10 – 7,50) %\nMnO (0,10 – 4,50) %\nCr2O3 (0,10 – 42,0) %\nP2O5 (0,10 – 31,0) %\nSO3 (0,10 – 11,0) %\nZrO2 (0,10 – 94,0) %\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF) PN-EN ISO 12677:2011 Wyroby i materialy ogniotrwale, zuzle, surowce, wyroby ceramiczne Zawartosc SiO2, Fe2O3, Al2O3, TiO2, CaO, MgO, K2O, Na2O, MnO, Cr2O3, P2O5, SO3, ZrO2\nZakres:\nSiO2 (0,10 – 99,9) %\nFe2O3 (0,10 – 99,8) %\nAl2O3 (0,10 – 99,9) %\nTiO2 (0,10 – 3,60) %\nCaO (0,10 – 98,0) %\nMgO (0,10 – 98,5) %\nK2O (0,10 – 11,0) %\nNa2O (0,10 – 7,50) %\nMnO (0,10 – 4,50) %\nCr2O3 (0,10 – 42,0) %\nP2O5 (0,10 – 31,0) %\nSO3 (0,10 – 11,0) %\nZrO2 (0,10 – 94,0) %\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersja fali (WD-XRF) PN-EN ISO 12677:2011","categories":["materials"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Refractory products and materials, slags, raw materials, ceramic products Content of SiO2, Fe2O3, Al2O3, TiO2, CaO, MgO, K2O, Na2O, MnO, Cr2O3, P2O5, SO3, ZrO2 Wavelength dispersive X-ray fluorescence spectrometry (WD-XRF) SiO2 Fe2O3 Al2O3 TiO2 CaO MgO K2O Na2O MnO Cr2O3 P2O5 SO3 ZrO2 PN-EN ISO 12677:2011","parameters_zh":[{"name":"SiO2","range":"(0,10 – 99,9) %"},{"name":"Fe2O3","range":"(0,10 – 99,8) %"},{"name":"Al2O3","range":"(0,10 – 99,9) %"},{"name":"TiO2","range":"(0,10 – 3,60) %"},{"name":"CaO","range":"(0,10 – 98,0) %"},{"name":"MgO","range":"(0,10 – 98,5) %"},{"name":"K2O","range":"(0,10 – 11,0) %"},{"name":"Na2O","range":"(0,10 – 7,50) %"},{"name":"MnO","range":"(0,10 – 4,50) %"},{"name":"Cr2O3","range":"(0,10 – 42,0) %"},{"name":"P2O5","range":"(0,10 – 31,0) %"},{"name":"SO3","range":"(0,10 – 11,0) %"},{"name":"ZrO2","range":"(0,10 – 94,0) %"}],"search_zh":"波长色散 X 射线荧光光谱法（WD-XRF） SiO2 Fe2O3 Al2O3 TiO2 CaO MgO K2O Na2O MnO P2O5 PN-EN ISO 12677:2011","technique_zh":"波长色散 X 射线荧光光谱法（WD-XRF）"},{"_id":"6a5dc9bbf1c10c8ce825dfce","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Odpady: kod 10 01 01, 10 01 02, 10 02 01, 10 01 80, 19 12 10, 19 12 11*","test_object_en":"Waste: code 10 01 01, 10 01 02, 10 02 01, 10 01 80, 19 12 10, 19 12 11*","methodology":"Zawartość SiO2, Fe2O3, Al2O3, CaO, MgO, K2O, Na2O, TiO2, Mn2O3, Cr2O3, P2O5","methodology_en":"Content of SiO2, Fe2O3, Al2O3, CaO, MgO, K2O, Na2O, TiO2, Mn2O3, Cr2O3, P2O5","parameters":[{"name":"SiO2","range":"(4,50 – 52,0) %"},{"name":"Fe2O3","range":"(0,50 – 80,0) %"},{"name":"Al2O3","range":"(1,00 – 30,0) %"},{"name":"CaO","range":"(3,00 – 50,0) %"},{"name":"MgO","range":"(0,20 – 6,00) %"},{"name":"K2O","range":"(0,10 – 2,10) %"},{"name":"Na2O","range":"(0,20 – 4,00) %"},{"name":"TiO2","range":"(0,10 – 12,5) %"},{"name":"Mn2O3","range":"(0,10 – 0,60) %"},{"name":"Cr2O3","range":"(0,10 – 0,20) %"},{"name":"P2O5","range":"(0,10 – 5,00) %"}],"parameters_en":[{"name":"SiO2","range":"(4,50 – 52,0) %"},{"name":"Fe2O3","range":"(0,50 – 80,0) %"},{"name":"Al2O3","range":"(1,00 – 30,0) %"},{"name":"CaO","range":"(3,00 – 50,0) %"},{"name":"MgO","range":"(0,20 – 6,00) %"},{"name":"K2O","range":"(0,10 – 2,10) %"},{"name":"Na2O","range":"(0,20 – 4,00) %"},{"name":"TiO2","range":"(0,10 – 12,5) %"},{"name":"Mn2O3","range":"(0,10 – 0,60) %"},{"name":"Cr2O3","range":"(0,10 – 0,20) %"},{"name":"P2O5","range":"(0,10 – 5,00) %"}],"technique":"Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF)","techniques":["Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF)"],"technique_en":"Wavelength dispersive X-ray fluorescence spectrometry (WD-XRF)","computed":[],"computed_en":[],"activity":"Zawartość SiO2, Fe2O3, Al2O3, CaO, MgO, K2O, Na2O, TiO2, Mn2O3, Cr2O3, P2O5\nZakres:\nSiO2 (4,50 – 52,0) %\nFe2O3 (0,50 – 80,0) %\nAl2O3 (1,00 – 30,0) %\nCaO (3,00 – 50,0) %\nMgO (0,20 – 6,00) %\nK2O (0,10 – 2,10) %\nNa2O (0,20 – 4,00) %\nTiO2 (0,10 – 12,5) %\nMn2O3 (0,10 – 0,60) %\nCr2O3 (0,10 – 0,20) %\nP2O5 (0,10 – 5,00) %\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF)","reference":"PN-EN 196-2:2013-11 | PB 34 wydanie 2 z dnia 21.02.2025 r.","norm_bases":["PN-EN 196-2:2013-11","PB 34 wydanie 2 z dnia 21.02.2025 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady: kod 10 01 01, 10 01 02, 10 02 01, 10 01 80, 19 12 10, 19 12 11* Zawartość SiO2, Fe2O3, Al2O3, CaO, MgO, K2O, Na2O, TiO2, Mn2O3, Cr2O3, P2O5\nZakres:\nSiO2 (4,50 – 52,0) %\nFe2O3 (0,50 – 80,0) %\nAl2O3 (1,00 – 30,0) %\nCaO (3,00 – 50,0) %\nMgO (0,20 – 6,00) %\nK2O (0,10 – 2,10) %\nNa2O (0,20 – 4,00) %\nTiO2 (0,10 – 12,5) %\nMn2O3 (0,10 – 0,60) %\nCr2O3 (0,10 – 0,20) %\nP2O5 (0,10 – 5,00) %\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF) PN-EN 196-2:2013-11 | PB 34 wydanie 2 z dnia 21.02.2025 r. Odpady: kod 10 01 01, 10 01 02, 10 02 01, 10 01 80, 19 12 10, 19 12 11* Zawartosc SiO2, Fe2O3, Al2O3, CaO, MgO, K2O, Na2O, TiO2, Mn2O3, Cr2O3, P2O5\nZakres:\nSiO2 (4,50 – 52,0) %\nFe2O3 (0,50 – 80,0) %\nAl2O3 (1,00 – 30,0) %\nCaO (3,00 – 50,0) %\nMgO (0,20 – 6,00) %\nK2O (0,10 – 2,10) %\nNa2O (0,20 – 4,00) %\nTiO2 (0,10 – 12,5) %\nMn2O3 (0,10 – 0,60) %\nCr2O3 (0,10 – 0,20) %\nP2O5 (0,10 – 5,00) %\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersja fali (WD-XRF) PN-EN 196-2:2013-11 | PB 34 wydanie 2 z dnia 21.02.2025 r.","categories":["environment"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste: code 10 01 01, 10 01 02, 10 02 01, 10 01 80, 19 12 10, 19 12 11* Content of SiO2, Fe2O3, Al2O3, CaO, MgO, K2O, Na2O, TiO2, Mn2O3, Cr2O3, P2O5 Wavelength dispersive X-ray fluorescence spectrometry (WD-XRF) SiO2 Fe2O3 Al2O3 CaO MgO K2O Na2O TiO2 Mn2O3 Cr2O3 P2O5 PN-EN 196-2:2013-11 | PB 34 wydanie 2 z dnia 21.02.2025 r.","parameters_zh":[{"name":"SiO2","range":"(4,50 – 52,0) %"},{"name":"Fe2O3","range":"(0,50 – 80,0) %"},{"name":"Al2O3","range":"(1,00 – 30,0) %"},{"name":"CaO","range":"(3,00 – 50,0) %"},{"name":"MgO","range":"(0,20 – 6,00) %"},{"name":"K2O","range":"(0,10 – 2,10) %"},{"name":"Na2O","range":"(0,20 – 4,00) %"},{"name":"TiO2","range":"(0,10 – 12,5) %"},{"name":"Mn2O3","range":"(0,10 – 0,60) %"},{"name":"Cr2O3","range":"(0,10 – 0,20) %"},{"name":"P2O5","range":"(0,10 – 5,00) %"}],"search_zh":"波长色散 X 射线荧光光谱法（WD-XRF） SiO2 Fe2O3 Al2O3 CaO MgO K2O Na2O TiO2 P2O5 PN-EN 196-2:2013-11 | PB 34 wydanie 2 z dnia 21.02.2025 r.","technique_zh":"波长色散 X 射线荧光光谱法（WD-XRF）"},{"_id":"6a5dc9bbf1c10c8ce825dfcf","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Cementy, składniki cementu, klinkiery, popioły lotne, żużle wielkopiecowe, pyły krzemionkowe, wapno, surowce do produkcji cementu, materiały wiążące, spoiwa mineralno-cementowe","test_object_en":"Cements, cement constituents, clinkers, fly ashes, blast furnace slags, silica fumes, lime, raw materials for cement production, binding materials, mineral-cement binders","methodology":"Zawartość SiO2, Fe2O3, Al2O3, TiO2, CaO, MgO, K2O, Na2O, Mn2O3, Cr2O3, P2O5, ZnO, SrO","methodology_en":"SiO2, Fe2O3, Al2O3, TiO2, CaO, MgO, K2O, Na2O, Mn2O3, Cr2O3, P2O5, ZnO, SrO content","parameters":[{"name":"SiO2","range":"(0,10 – 99,0) %"},{"name":"Fe2O3","range":"(0,10 – 80,0) %"},{"name":"Al2O3","range":"(0,10 – 90,0) %"},{"name":"TiO2","range":"(0,10 – 3,50) %"},{"name":"CaO","range":"(0,10 – 98,0) %"},{"name":"MgO","range":"(0,10 – 80,0) %"},{"name":"K2O","range":"(0,10 – 11,5) %"},{"name":"Na2O","range":"(0,10 – 9,00) %"},{"name":"Mn2O3","range":"(0,10 – 5,00) %"},{"name":"Cr2O3","range":"(0,10 – 3,50) %"},{"name":"P2O5","range":"(0,10 – 8,50) %"},{"name":"ZnO","range":"(0,10 – 10,0) %"},{"name":"SrO","range":"(0,10 – 1,20) %"}],"parameters_en":[{"name":"SiO2","range":"(0,10 – 99,0) %"},{"name":"Fe2O3","range":"(0,10 – 80,0) %"},{"name":"Al2O3","range":"(0,10 – 90,0) %"},{"name":"TiO2","range":"(0,10 – 3,50) %"},{"name":"CaO","range":"(0,10 – 98,0) %"},{"name":"MgO","range":"(0,10 – 80,0) %"},{"name":"K2O","range":"(0,10 – 11,5) %"},{"name":"Na2O","range":"(0,10 – 9,00) %"},{"name":"Mn2O3","range":"(0,10 – 5,00) %"},{"name":"Cr2O3","range":"(0,10 – 3,50) %"},{"name":"P2O5","range":"(0,10 – 8,50) %"},{"name":"ZnO","range":"(0,10 – 10,0) %"},{"name":"SrO","range":"(0,10 – 1,20) %"}],"technique":"Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF)","techniques":["Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF)"],"technique_en":"Wavelength dispersive X-ray fluorescence spectrometry (WD-XRF)","computed":[],"computed_en":[],"activity":"Zawartość SiO2, Fe2O3, Al2O3, TiO2, CaO, MgO, K2O, Na2O, Mn2O3, Cr2O3, P2O5, ZnO, SrO\nZakres:\nSiO2 (0,10 – 99,0) %\nFe2O3 (0,10 – 80,0) %\nAl2O3 (0,10 – 90,0) %\nTiO2 (0,10 – 3,50) %\nCaO (0,10 – 98,0) %\nMgO (0,10 – 80,0) %\nK2O (0,10 – 11,5) %\nNa2O (0,10 – 9,00) %\nMn2O3 (0,10 – 5,00) %\nCr2O3 (0,10 – 3,50) %\nP2O5 (0,10 – 8,50) %\nZnO (0,10 – 10,0) %\nSrO (0,10 – 1,20) %\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF)","reference":"PN-EN 196-2:2013-11","norm_bases":["PN-EN 196-2:2013-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Cementy, składniki cementu, klinkiery, popioły lotne, żużle wielkopiecowe, pyły krzemionkowe, wapno, surowce do produkcji cementu, materiały wiążące, spoiwa mineralno-cementowe Zawartość SiO2, Fe2O3, Al2O3, TiO2, CaO, MgO, K2O, Na2O, Mn2O3, Cr2O3, P2O5, ZnO, SrO\nZakres:\nSiO2 (0,10 – 99,0) %\nFe2O3 (0,10 – 80,0) %\nAl2O3 (0,10 – 90,0) %\nTiO2 (0,10 – 3,50) %\nCaO (0,10 – 98,0) %\nMgO (0,10 – 80,0) %\nK2O (0,10 – 11,5) %\nNa2O (0,10 – 9,00) %\nMn2O3 (0,10 – 5,00) %\nCr2O3 (0,10 – 3,50) %\nP2O5 (0,10 – 8,50) %\nZnO (0,10 – 10,0) %\nSrO (0,10 – 1,20) %\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF) PN-EN 196-2:2013-11 Cementy, skladniki cementu, klinkiery, popioly lotne, zuzle wielkopiecowe, pyly krzemionkowe, wapno, surowce do produkcji cementu, materialy wiazace, spoiwa mineralno-cementowe Zawartosc SiO2, Fe2O3, Al2O3, TiO2, CaO, MgO, K2O, Na2O, Mn2O3, Cr2O3, P2O5, ZnO, SrO\nZakres:\nSiO2 (0,10 – 99,0) %\nFe2O3 (0,10 – 80,0) %\nAl2O3 (0,10 – 90,0) %\nTiO2 (0,10 – 3,50) %\nCaO (0,10 – 98,0) %\nMgO (0,10 – 80,0) %\nK2O (0,10 – 11,5) %\nNa2O (0,10 – 9,00) %\nMn2O3 (0,10 – 5,00) %\nCr2O3 (0,10 – 3,50) %\nP2O5 (0,10 – 8,50) %\nZnO (0,10 – 10,0) %\nSrO (0,10 – 1,20) %\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersja fali (WD-XRF) PN-EN 196-2:2013-11","categories":["construction","materials"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cements, cement constituents, clinkers, fly ashes, blast furnace slags, silica fumes, lime, raw materials for cement production, binding materials, mineral-cement binders SiO2, Fe2O3, Al2O3, TiO2, CaO, MgO, K2O, Na2O, Mn2O3, Cr2O3, P2O5, ZnO, SrO content Wavelength dispersive X-ray fluorescence spectrometry (WD-XRF) SiO2 Fe2O3 Al2O3 TiO2 CaO MgO K2O Na2O Mn2O3 Cr2O3 P2O5 ZnO SrO PN-EN 196-2:2013-11","parameters_zh":[{"name":"SiO2","range":"(0,10 – 99,0) %"},{"name":"Fe2O3","range":"(0,10 – 80,0) %"},{"name":"Al2O3","range":"(0,10 – 90,0) %"},{"name":"TiO2","range":"(0,10 – 3,50) %"},{"name":"CaO","range":"(0,10 – 98,0) %"},{"name":"MgO","range":"(0,10 – 80,0) %"},{"name":"K2O","range":"(0,10 – 11,5) %"},{"name":"Na2O","range":"(0,10 – 9,00) %"},{"name":"Mn2O3","range":"(0,10 – 5,00) %"},{"name":"Cr2O3","range":"(0,10 – 3,50) %"},{"name":"P2O5","range":"(0,10 – 8,50) %"},{"name":"ZnO","range":"(0,10 – 10,0) %"},{"name":"SrO","range":"(0,10 – 1,20) %"}],"search_zh":"波长色散 X 射线荧光光谱法（WD-XRF） SiO2 Fe2O3 Al2O3 TiO2 CaO MgO K2O Na2O P2O5 ZnO SrO PN-EN 196-2:2013-11","technique_zh":"波长色散 X 射线荧光光谱法（WD-XRF）"},{"_id":"6a5dc9bbf1c10c8ce825dfd0","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Cementy, składniki cementu, klinkiery, popioły lotne, żużle wielkopiecowe, pyły krzemionkowe, wapno, surowce do produkcji cementu, materiały wiążące, spoiwa mineralno-cementowe","test_object_en":"Cements, cement constituents, clinkers, fly ashes, blast furnace slags, silica fumes, lime, raw materials for cement production, binding materials, mineral-cement binders","methodology":"Strata prażenia","methodology_en":"Loss on ignition","parameters":[{"name":"Zakres","range":"(0,40 – 44,0) %"},{"name":"Zakres","range":"(0,20 – 28,0) %"}],"parameters_en":[{"name":"Range","range":"(0,40 – 44,0) %"},{"name":"Range","range":"(0,20 – 28,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Strata prażenia\nZakres:\nZakres (0,40 – 44,0) %\nZakres (0,20 – 28,0) %\nMetoda wagowa","reference":"PN-EN 196-2:2013-11 | PN-EN 450-1:2012 | PN-EN 13263-1+A1:2010 | PN-EN 459-2:2021-12","norm_bases":["PN-EN 196-2:2013-11","PN-EN 450-1:2012","PN-EN 13263-1+A1:2010","PN-EN 459-2:2021-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Cementy, składniki cementu, klinkiery, popioły lotne, żużle wielkopiecowe, pyły krzemionkowe, wapno, surowce do produkcji cementu, materiały wiążące, spoiwa mineralno-cementowe Strata prażenia\nZakres:\nZakres (0,40 – 44,0) %\nZakres (0,20 – 28,0) %\nMetoda wagowa PN-EN 196-2:2013-11 | PN-EN 450-1:2012 | PN-EN 13263-1+A1:2010 | PN-EN 459-2:2021-12 Cementy, skladniki cementu, klinkiery, popioly lotne, zuzle wielkopiecowe, pyly krzemionkowe, wapno, surowce do produkcji cementu, materialy wiazace, spoiwa mineralno-cementowe Strata prazenia\nZakres:\nZakres (0,40 – 44,0) %\nZakres (0,20 – 28,0) %\nMetoda wagowa PN-EN 196-2:2013-11 | PN-EN 450-1:2012 | PN-EN 13263-1+A1:2010 | PN-EN 459-2:2021-12","categories":["construction","materials"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cements, cement constituents, clinkers, fly ashes, blast furnace slags, silica fumes, lime, raw materials for cement production, binding materials, mineral-cement binders Loss on ignition Gravimetric method Range Range PN-EN 196-2:2013-11 | PN-EN 450-1:2012 | PN-EN 13263-1+A1:2010 | PN-EN 459-2:2021-12","parameters_zh":[{"name":"范围","range":"(0,40 – 44,0) %"},{"name":"范围","range":"(0,20 – 28,0) %"}],"search_zh":"烧失量 重量法 范围 范围 PN-EN 196-2:2013-11 | PN-EN 450-1:2012 | PN-EN 13263-1+A1:2010 | PN-EN 459-2:2021-12","technique_zh":"重量法","methodology_zh":"烧失量"},{"_id":"6a5dc9bbf1c10c8ce825dfd1","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Popiół z paliw stałych","test_object_en":"Ash from solid fuels","methodology":"Zawartość SiO2, Fe2O3, Al2O3, TiO2, CaO, MgO, K2O, Na2O, Mn2O3, Cr2O3, P2O5, ZnO, SrO","methodology_en":"SiO2, Fe2O3, Al2O3, TiO2, CaO, MgO, K2O, Na2O, Mn2O3, Cr2O3, P2O5, ZnO, SrO content","parameters":[{"name":"SiO2","range":"(8,50 – 52,0) %"},{"name":"Fe2O3","range":"(2,50 – 12,0) %"},{"name":"Al2O3","range":"(4,00 – 30,0) %"},{"name":"TiO2","range":"(0,70 – 3,00) %"},{"name":"CaO","range":"(2,00 – 35,0) %"},{"name":"MgO","range":"(1,00 – 10,0) %"},{"name":"K2O","range":"(0,90 – 10,0) %"},{"name":"Na2O","range":"(0,30 – 2,00) %"},{"name":"Mn2O3","range":"(0,10 – 2,00) %"},{"name":"Cr2O3","range":"(0,10 – 0,20) %"},{"name":"P2O5","range":"(1,00 – 4,50) %"},{"name":"ZnO","range":"(0,30 – 0,50) %"},{"name":"SrO","range":"(0,10 – 0,40) %"}],"parameters_en":[{"name":"SiO2","range":"(8,50 – 52,0) %"},{"name":"Fe2O3","range":"(2,50 – 12,0) %"},{"name":"Al2O3","range":"(4,00 – 30,0) %"},{"name":"TiO2","range":"(0,70 – 3,00) %"},{"name":"CaO","range":"(2,00 – 35,0) %"},{"name":"MgO","range":"(1,00 – 10,0) %"},{"name":"K2O","range":"(0,90 – 10,0) %"},{"name":"Na2O","range":"(0,30 – 2,00) %"},{"name":"Mn2O3","range":"(0,10 – 2,00) %"},{"name":"Cr2O3","range":"(0,10 – 0,20) %"},{"name":"P2O5","range":"(1,00 – 4,50) %"},{"name":"ZnO","range":"(0,30 – 0,50) %"},{"name":"SrO","range":"(0,10 – 0,40) %"}],"technique":"Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF)","techniques":["Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF)"],"technique_en":"Wavelength dispersive X-ray fluorescence spectrometry (WD-XRF)","computed":[],"computed_en":[],"activity":"Zawartość SiO2, Fe2O3, Al2O3, TiO2, CaO, MgO, K2O, Na2O, Mn2O3, Cr2O3, P2O5, ZnO, SrO\nZakres:\nSiO2 (8,50 – 52,0) %\nFe2O3 (2,50 – 12,0) %\nAl2O3 (4,00 – 30,0) %\nTiO2 (0,70 – 3,00) %\nCaO (2,00 – 35,0) %\nMgO (1,00 – 10,0) %\nK2O (0,90 – 10,0) %\nNa2O (0,30 – 2,00) %\nMn2O3 (0,10 – 2,00) %\nCr2O3 (0,10 – 0,20) %\nP2O5 (1,00 – 4,50) %\nZnO (0,30 – 0,50) %\nSrO (0,10 – 0,40) %\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF)","reference":"PN-EN 196-2:2013-11","norm_bases":["PN-EN 196-2:2013-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Popiół z paliw stałych Zawartość SiO2, Fe2O3, Al2O3, TiO2, CaO, MgO, K2O, Na2O, Mn2O3, Cr2O3, P2O5, ZnO, SrO\nZakres:\nSiO2 (8,50 – 52,0) %\nFe2O3 (2,50 – 12,0) %\nAl2O3 (4,00 – 30,0) %\nTiO2 (0,70 – 3,00) %\nCaO (2,00 – 35,0) %\nMgO (1,00 – 10,0) %\nK2O (0,90 – 10,0) %\nNa2O (0,30 – 2,00) %\nMn2O3 (0,10 – 2,00) %\nCr2O3 (0,10 – 0,20) %\nP2O5 (1,00 – 4,50) %\nZnO (0,30 – 0,50) %\nSrO (0,10 – 0,40) %\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF) PN-EN 196-2:2013-11 Popiol z paliw stalych Zawartosc SiO2, Fe2O3, Al2O3, TiO2, CaO, MgO, K2O, Na2O, Mn2O3, Cr2O3, P2O5, ZnO, SrO\nZakres:\nSiO2 (8,50 – 52,0) %\nFe2O3 (2,50 – 12,0) %\nAl2O3 (4,00 – 30,0) %\nTiO2 (0,70 – 3,00) %\nCaO (2,00 – 35,0) %\nMgO (1,00 – 10,0) %\nK2O (0,90 – 10,0) %\nNa2O (0,30 – 2,00) %\nMn2O3 (0,10 – 2,00) %\nCr2O3 (0,10 – 0,20) %\nP2O5 (1,00 – 4,50) %\nZnO (0,30 – 0,50) %\nSrO (0,10 – 0,40) %\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersja fali (WD-XRF) PN-EN 196-2:2013-11","categories":["petro"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Ash from solid fuels SiO2, Fe2O3, Al2O3, TiO2, CaO, MgO, K2O, Na2O, Mn2O3, Cr2O3, P2O5, ZnO, SrO content Wavelength dispersive X-ray fluorescence spectrometry (WD-XRF) SiO2 Fe2O3 Al2O3 TiO2 CaO MgO K2O Na2O Mn2O3 Cr2O3 P2O5 ZnO SrO PN-EN 196-2:2013-11","parameters_zh":[{"name":"SiO2","range":"(8,50 – 52,0) %"},{"name":"Fe2O3","range":"(2,50 – 12,0) %"},{"name":"Al2O3","range":"(4,00 – 30,0) %"},{"name":"TiO2","range":"(0,70 – 3,00) %"},{"name":"CaO","range":"(2,00 – 35,0) %"},{"name":"MgO","range":"(1,00 – 10,0) %"},{"name":"K2O","range":"(0,90 – 10,0) %"},{"name":"Na2O","range":"(0,30 – 2,00) %"},{"name":"Mn2O3","range":"(0,10 – 2,00) %"},{"name":"Cr2O3","range":"(0,10 – 0,20) %"},{"name":"P2O5","range":"(1,00 – 4,50) %"},{"name":"ZnO","range":"(0,30 – 0,50) %"},{"name":"SrO","range":"(0,10 – 0,40) %"}],"search_zh":"波长色散 X 射线荧光光谱法（WD-XRF） SiO2 Fe2O3 Al2O3 TiO2 CaO MgO K2O Na2O P2O5 ZnO SrO PN-EN 196-2:2013-11","technique_zh":"波长色散 X 射线荧光光谱法（WD-XRF）"},{"_id":"6a5dc9bbf1c10c8ce825dfd2","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Cementy, składniki cementu, klinkiery, popioły lotne, żużle wielkopiecowe, pyły krzemionkowe, wapno, materiały wiążące, spoiwa mineralno-cementowe","test_object_en":"Cements, cement constituents, clinkers, fly ashes, blast furnace slags, silica fumes, lime, binding materials, mineral-cement binders","methodology":"Zawartość chlorków Cl","methodology_en":"Chloride content Cl","parameters":[{"name":"Zakres","range":"(0,002 – 0,920) %"}],"parameters_en":[{"name":"Range","range":"(0,002 – 0,920) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Zawartość chlorków Cl\nZakres (0,002 – 0,920) %\nMetoda miareczkowa","reference":"PN-EN 196-2:2013-11","norm_bases":["PN-EN 196-2:2013-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Cementy, składniki cementu, klinkiery, popioły lotne, żużle wielkopiecowe, pyły krzemionkowe, wapno, materiały wiążące, spoiwa mineralno-cementowe Zawartość chlorków Cl\nZakres (0,002 – 0,920) %\nMetoda miareczkowa PN-EN 196-2:2013-11 Cementy, skladniki cementu, klinkiery, popioly lotne, zuzle wielkopiecowe, pyly krzemionkowe, wapno, materialy wiazace, spoiwa mineralno-cementowe Zawartosc chlorkow Cl\nZakres (0,002 – 0,920) %\nMetoda miareczkowa PN-EN 196-2:2013-11","categories":["construction","materials"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cements, cement constituents, clinkers, fly ashes, blast furnace slags, silica fumes, lime, binding materials, mineral-cement binders Chloride content Cl Titrimetric method Range PN-EN 196-2:2013-11","parameters_zh":[{"name":"范围","range":"(0,002 – 0,920) %"}],"search_zh":"滴定法 范围 PN-EN 196-2:2013-11","technique_zh":"滴定法"},{"_id":"6a5dc9bbf1c10c8ce825dfd3","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Cementy, składniki cementu, klinkiery, popioły lotne, żużle wielkopiecowe, pyły krzemionkowe, wapno, materiały wiążące, spoiwa mineralno-cementowe","test_object_en":"Cements, cement constituents, clinkers, fly ashes, blast furnace slags, silica fumes, lime, binding materials, mineral-cement binders","methodology":"Zawartość siarczanów SO3","methodology_en":"Sulphate content SO3","parameters":[{"name":"Zakres","range":"(0,05 – 52,00) %"}],"parameters_en":[{"name":"Range","range":"(0,05 – 52,00) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość siarczanów SO3\nZakres (0,05 – 52,00) %\nMetoda wagowa","reference":"PN-EN 196-2:2013-11","norm_bases":["PN-EN 196-2:2013-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Cementy, składniki cementu, klinkiery, popioły lotne, żużle wielkopiecowe, pyły krzemionkowe, wapno, materiały wiążące, spoiwa mineralno-cementowe Zawartość siarczanów SO3\nZakres (0,05 – 52,00) %\nMetoda wagowa PN-EN 196-2:2013-11 Cementy, skladniki cementu, klinkiery, popioly lotne, zuzle wielkopiecowe, pyly krzemionkowe, wapno, materialy wiazace, spoiwa mineralno-cementowe Zawartosc siarczanow SO3\nZakres (0,05 – 52,00) %\nMetoda wagowa PN-EN 196-2:2013-11","categories":["construction","materials"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cements, cement constituents, clinkers, fly ashes, blast furnace slags, silica fumes, lime, binding materials, mineral-cement binders Sulphate content SO3 Gravimetric method Range PN-EN 196-2:2013-11","parameters_zh":[{"name":"范围","range":"(0,05 – 52,00) %"}],"search_zh":"重量法 范围 PN-EN 196-2:2013-11","technique_zh":"重量法"},{"_id":"6a5dc9bbf1c10c8ce825dfd4","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Cementy, popioły lotne, materiały wiążące, spoiwa mineralno- cementowe","test_object_en":"Cements, fly ashes, binding materials, mineral-cement binders","methodology":"Zawartość części nierozpuszczalnych","methodology_en":"Content of insoluble matter","parameters":[{"name":"Zakres","range":"(0,40 – 60,00)%"}],"parameters_en":[{"name":"Range","range":"(0,40 – 60,00)%"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość części nierozpuszczalnych\nZakres (0,40 – 60,00)%\nMetoda wagowa","reference":"PN-EN 196-2:2013-11","norm_bases":["PN-EN 196-2:2013-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Cementy, popioły lotne, materiały wiążące, spoiwa mineralno- cementowe Zawartość części nierozpuszczalnych\nZakres (0,40 – 60,00)%\nMetoda wagowa PN-EN 196-2:2013-11 Cementy, popioly lotne, materialy wiazace, spoiwa mineralno- cementowe Zawartosc czesci nierozpuszczalnych\nZakres (0,40 – 60,00)%\nMetoda wagowa PN-EN 196-2:2013-11","categories":["materials","construction"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cements, fly ashes, binding materials, mineral-cement binders Content of insoluble matter Gravimetric method Range PN-EN 196-2:2013-11","parameters_zh":[{"name":"范围","range":"(0,40 – 60,00)%"}],"search_zh":"不溶物含量 重量法 范围 PN-EN 196-2:2013-11","technique_zh":"重量法","methodology_zh":"不溶物含量"},{"_id":"6a5dc9bbf1c10c8ce825dfd5","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Popioły lotne, pyły krzemionkowe","test_object_en":"Fly ashes, silica fume","methodology":"Zawartość wolnego tlenku wapnia","methodology_en":"Free calcium oxide content","parameters":[{"name":"Zakres","range":"(0,01 – 20,0) %"}],"parameters_en":[{"name":"Range","range":"(0,01 – 20,0) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Zawartość wolnego tlenku wapnia\nZakres (0,01 – 20,0) %\nMetoda miareczkowa","reference":"PN-EN 451-1:2017-06","norm_bases":["PN-EN 451-1:2017-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Popioły lotne, pyły krzemionkowe Zawartość wolnego tlenku wapnia\nZakres (0,01 – 20,0) %\nMetoda miareczkowa PN-EN 451-1:2017-06 Popioly lotne, pyly krzemionkowe Zawartosc wolnego tlenku wapnia\nZakres (0,01 – 20,0) %\nMetoda miareczkowa PN-EN 451-1:2017-06","categories":["other"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Fly ashes, silica fume Free calcium oxide content Titrimetric method Range PN-EN 451-1:2017-06","parameters_zh":[{"name":"范围","range":"(0,01 – 20,0) %"}],"search_zh":"游离氧化钙含量 滴定法 范围 PN-EN 451-1:2017-06","technique_zh":"滴定法","methodology_zh":"游离氧化钙含量"},{"_id":"6a5dc9bbf1c10c8ce825dfd6","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Wapno, kruszywa","test_object_en":"Lime, aggregates","methodology":"Zawartość wapna czynnego","methodology_en":"Active lime content","parameters":[{"name":"Zakres","range":"(0,20 – 95,0) %"}],"parameters_en":[{"name":"Range","range":"(0,20 – 95,0) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Zawartość wapna czynnego\nZakres (0,20 – 95,0) %\nMetoda miareczkowa","reference":"PN-EN 459-2:2021-12","norm_bases":["PN-EN 459-2:2021-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wapno, kruszywa Zawartość wapna czynnego\nZakres (0,20 – 95,0) %\nMetoda miareczkowa PN-EN 459-2:2021-12 Wapno, kruszywa Zawartosc wapna czynnego\nZakres (0,20 – 95,0) %\nMetoda miareczkowa PN-EN 459-2:2021-12","categories":["other"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Lime, aggregates Active lime content Titrimetric method Range PN-EN 459-2:2021-12","parameters_zh":[{"name":"范围","range":"(0,20 – 95,0) %"}],"search_zh":"滴定法 范围 PN-EN 459-2:2021-12","technique_zh":"滴定法"},{"_id":"6a5dc9bbf1c10c8ce825dfd7","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Wapno","test_object_en":"Lime","methodology":"Wolna woda (wilgoć)","methodology_en":"Free water (moisture)","parameters":[{"name":"Zakres","range":"(0,05 – 60,0) %"}],"parameters_en":[{"name":"Range","range":"(0,05 – 60,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Wolna woda (wilgoć)\nZakres (0,05 – 60,0) %\nMetoda wagowa","reference":"PN-EN 459-2:2021-12","norm_bases":["PN-EN 459-2:2021-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wapno Wolna woda (wilgoć)\nZakres (0,05 – 60,0) %\nMetoda wagowa PN-EN 459-2:2021-12 Wapno Wolna woda (wilgoc)\nZakres (0,05 – 60,0) %\nMetoda wagowa PN-EN 459-2:2021-12","categories":["water"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Lime Free water (moisture) Gravimetric method Range PN-EN 459-2:2021-12","parameters_zh":[{"name":"范围","range":"(0,05 – 60,0) %"}],"search_zh":"重量法 范围 PN-EN 459-2:2021-12","technique_zh":"重量法"},{"_id":"6a5dc9bbf1c10c8ce825dfd8","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Cementy","test_object_en":"Cements","methodology":"Gęstość ziarn","methodology_en":"Particle density","parameters":[{"name":"Zakres","range":"(1,00 – 5,00) g/cm3"}],"parameters_en":[{"name":"Range","range":"(1,00 – 5,00) g/cm3"}],"technique":"Metoda za pomocą piknometru","techniques":["Metoda za pomocą piknometru"],"technique_en":"Method using a pycnometer","computed":[],"computed_en":[],"activity":"Gęstość ziarn\nZakres (1,00 – 5,00) g/cm3\nMetoda za pomocą piknometru","reference":"PN-EN 196-6:2019-01","norm_bases":["PN-EN 196-6:2019-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Cementy Gęstość ziarn\nZakres (1,00 – 5,00) g/cm3\nMetoda za pomocą piknometru PN-EN 196-6:2019-01 Cementy Gestosc ziarn\nZakres (1,00 – 5,00) g/cm3\nMetoda za pomoca piknometru PN-EN 196-6:2019-01","categories":["construction"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cements Particle density Method using a pycnometer Range PN-EN 196-6:2019-01","parameters_zh":[{"name":"范围","range":"(1,00 – 5,00) g/cm3"}],"search_zh":"水泥 颗粒密度 范围 PN-EN 196-6:2019-01","test_object_zh":"水泥","methodology_zh":"颗粒密度"},{"_id":"6a5dc9bbf1c10c8ce825dfd9","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Cementy","test_object_en":"Cements","methodology":"Powierzchnia właściwa","methodology_en":"Specific surface area","parameters":[],"parameters_en":[],"technique":"Metoda za pomocą aparatu Blaine'a","techniques":["Metoda za pomocą aparatu Blaine'a"],"technique_en":"Method using the Blaine apparatus","computed":[],"computed_en":[],"activity":"Powierzchnia właściwa\nMetoda za pomocą aparatu Blaine'a","reference":"PN-EN 196-6:2019-01","norm_bases":["PN-EN 196-6:2019-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Cementy Powierzchnia właściwa\nMetoda za pomocą aparatu Blaine'a PN-EN 196-6:2019-01 Cementy Powierzchnia wlasciwa\nMetoda za pomoca aparatu Blaine'a PN-EN 196-6:2019-01","categories":["construction"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cements Specific surface area Method using the Blaine apparatus PN-EN 196-6:2019-01","methodology_zh":"比表面积","search_zh":"水泥 比表面积 PN-EN 196-6:2019-01","test_object_zh":"水泥"},{"_id":"6a5dc9bbf1c10c8ce825dfda","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Cementy","test_object_en":"Cements","methodology":"Zawartość chromu Cr (VI) rozpuszczalnego w wodzie","methodology_en":"Water-soluble chromium Cr (VI) content","parameters":[{"name":"Zakres","range":"(0,000005 – 0,00050)%"}],"parameters_en":[{"name":"Range","range":"(0,000005 – 0,00050)%"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Zawartość chromu Cr (VI) rozpuszczalnego w wodzie\nZakres (0,000005 – 0,00050)%\nMetoda spektrofotometryczna","reference":"PN-EN 196-10:2016-07","norm_bases":["PN-EN 196-10:2016-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Cementy Zawartość chromu Cr (VI) rozpuszczalnego w wodzie\nZakres (0,000005 – 0,00050)%\nMetoda spektrofotometryczna PN-EN 196-10:2016-07 Cementy Zawartosc chromu Cr (VI) rozpuszczalnego w wodzie\nZakres (0,000005 – 0,00050)%\nMetoda spektrofotometryczna PN-EN 196-10:2016-07","categories":["construction"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cements Water-soluble chromium Cr (VI) content Spectrophotometric method Range PN-EN 196-10:2016-07","parameters_zh":[{"name":"范围","range":"(0,000005 – 0,00050)%"}],"search_zh":"水泥 分光光度法 范围 PN-EN 196-10:2016-07","technique_zh":"分光光度法","test_object_zh":"水泥"},{"_id":"6a5dc9bbf1c10c8ce825dfdb","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Cementy","test_object_en":"Cements","methodology":"Udział popiołu lotnego w cemencie (z obliczeń)","methodology_en":"Fly ash content in cement (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Udział popiołu lotnego w cemencie (z obliczeń)","reference":"PN-B-19707:2023-05","norm_bases":["PN-B-19707:2023-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Cementy Udział popiołu lotnego w cemencie (z obliczeń) PN-B-19707:2023-05 Cementy Udzial popiolu lotnego w cemencie (z obliczen) PN-B-19707:2023-05","categories":["construction"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cements Fly ash content in cement (calculated) PN-B-19707:2023-05","search_zh":"水泥 PN-B-19707:2023-05","test_object_zh":"水泥"},{"_id":"6a5dc9bbf1c10c8ce825dfdc","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Popioły lotne","test_object_en":"Fly ashes","methodology":"Miałkość","methodology_en":"Fineness","parameters":[{"name":"Zakres","range":"(0,1 – 70,0) %"}],"parameters_en":[{"name":"Range","range":"(0,1 – 70,0) %"}],"technique":"Metoda sitowa","techniques":["Metoda sitowa"],"technique_en":"Sieve method","computed":[],"computed_en":[],"activity":"Miałkość\nZakres (0,1 – 70,0) %\nMetoda sitowa","reference":"PN-EN 451-2:2017-06","norm_bases":["PN-EN 451-2:2017-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Popioły lotne Miałkość\nZakres (0,1 – 70,0) %\nMetoda sitowa PN-EN 451-2:2017-06 Popioly lotne Mialkosc\nZakres (0,1 – 70,0) %\nMetoda sitowa PN-EN 451-2:2017-06","categories":["other"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Fly ashes Fineness Sieve method Range PN-EN 451-2:2017-06","parameters_zh":[{"name":"范围","range":"(0,1 – 70,0) %"}],"search_zh":"飞灰 细度 筛析法 范围 PN-EN 451-2:2017-06","technique_zh":"筛析法","methodology_zh":"细度","test_object_zh":"飞灰"},{"_id":"6a5dc9bbf1c10c8ce825dfdd","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Popioły lotne","test_object_en":"Fly ashes","methodology":"Zawartość reaktywnego CaO (z obliczeń)","methodology_en":"Reactive CaO content (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość reaktywnego CaO (z obliczeń)","reference":"PN-EN 197-1:2012 | PN-EN 450-1:2012","norm_bases":["PN-EN 197-1:2012","PN-EN 450-1:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Popioły lotne Zawartość reaktywnego CaO (z obliczeń) PN-EN 197-1:2012 | PN-EN 450-1:2012 Popioly lotne Zawartosc reaktywnego CaO (z obliczen) PN-EN 197-1:2012 | PN-EN 450-1:2012","categories":["other"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Fly ashes Reactive CaO content (calculated) PN-EN 197-1:2012 | PN-EN 450-1:2012","search_zh":"飞灰 PN-EN 197-1:2012 | PN-EN 450-1:2012","test_object_zh":"飞灰"},{"_id":"6a5dc9bbf1c10c8ce825dfde","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Popioły lotne","test_object_en":"Fly ashes","methodology":"Zawartość reaktywnego SiO2 (z obliczeń)","methodology_en":"Reactive SiO2 content (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość reaktywnego SiO2 (z obliczeń)","reference":"PN-EN 197-1:2012 | PN-EN 450-1:2012","norm_bases":["PN-EN 197-1:2012","PN-EN 450-1:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Popioły lotne Zawartość reaktywnego SiO2 (z obliczeń) PN-EN 197-1:2012 | PN-EN 450-1:2012 Popioly lotne Zawartosc reaktywnego SiO2 (z obliczen) PN-EN 197-1:2012 | PN-EN 450-1:2012","categories":["other"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Fly ashes Reactive SiO2 content (calculated) PN-EN 197-1:2012 | PN-EN 450-1:2012","search_zh":"飞灰 PN-EN 197-1:2012 | PN-EN 450-1:2012","test_object_zh":"飞灰"},{"_id":"6a5dc9bbf1c10c8ce825dfdf","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Cementy, surowce, kruszywa wypełniające, popiół lotny","test_object_en":"Cements, raw materials, filler aggregates, fly ash","methodology":"Zawartość dwutlenku węgla","methodology_en":"Carbon dioxide content","parameters":[{"name":"Zakres","range":"(0,01 – 47,0) %"}],"parameters_en":[{"name":"Range","range":"(0,01 – 47,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość dwutlenku węgla\nZakres (0,01 – 47,0) %\nMetoda wagowa","reference":"PN-EN 196-2:2013-11 p. 4.5.17","norm_bases":["PN-EN 196-2:2013-11 p. 4.5.17"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Cementy, surowce, kruszywa wypełniające, popiół lotny Zawartość dwutlenku węgla\nZakres (0,01 – 47,0) %\nMetoda wagowa PN-EN 196-2:2013-11 p. 4.5.17 Cementy, surowce, kruszywa wypelniajace, popiol lotny Zawartosc dwutlenku wegla\nZakres (0,01 – 47,0) %\nMetoda wagowa PN-EN 196-2:2013-11 p. 4.5.17","categories":["construction"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cements, raw materials, filler aggregates, fly ash Carbon dioxide content Gravimetric method Range PN-EN 196-2:2013-11 p. 4.5.17","parameters_zh":[{"name":"范围","range":"(0,01 – 47,0) %"}],"search_zh":"二氧化碳含量 重量法 范围 PN-EN 196-2:2013-11 p. 4.5.17","technique_zh":"重量法","methodology_zh":"二氧化碳含量"},{"_id":"6a5dc9bbf1c10c8ce825dfe0","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Surowce, materiały ceramiczne, materiały budowlane","test_object_en":"Raw materials, ceramic materials, construction materials","methodology":"Zawartość węgla nieorganicznego TIC","methodology_en":"Content of inorganic carbon TIC","parameters":[{"name":"Zakres","range":"(0,10 – 12,0) %"}],"parameters_en":[{"name":"Range","range":"(0,10 – 12,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość węgla nieorganicznego TIC\nZakres (0,10 – 12,0) %\nMetoda wagowa","reference":"PN-EN 15936:2022-07 metoda A","norm_bases":["PN-EN 15936:2022-07 metoda A"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Surowce, materiały ceramiczne, materiały budowlane Zawartość węgla nieorganicznego TIC\nZakres (0,10 – 12,0) %\nMetoda wagowa PN-EN 15936:2022-07 metoda A Surowce, materialy ceramiczne, materialy budowlane Zawartosc wegla nieorganicznego TIC\nZakres (0,10 – 12,0) %\nMetoda wagowa PN-EN 15936:2022-07 metoda A","categories":["materials","construction"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Raw materials, ceramic materials, construction materials Content of inorganic carbon TIC Gravimetric method Range PN-EN 15936:2022-07 metoda A","parameters_zh":[{"name":"范围","range":"(0,10 – 12,0) %"}],"search_zh":"重量法 范围 PN-EN 15936:2022-07 metoda A","technique_zh":"重量法"},{"_id":"6a5dc9bbf1c10c8ce825dfe1","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Węglik krzemu, wyroby z dodatkiem węglika krzemu","test_object_en":"Silicon carbide, products containing silicon carbide","methodology":"Zawartość SiC","methodology_en":"SiC content","parameters":[{"name":"Zakres","range":"(0,10 – 99,0) %"}],"parameters_en":[{"name":"Range","range":"(0,10 – 99,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość SiC\nZakres (0,10 – 99,0) %\nMetoda wagowa","reference":"PN-86/H-04157 p. 3.2","norm_bases":["PN-86/H-04157 p. 3.2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Węglik krzemu, wyroby z dodatkiem węglika krzemu Zawartość SiC\nZakres (0,10 – 99,0) %\nMetoda wagowa PN-86/H-04157 p. 3.2 Weglik krzemu, wyroby z dodatkiem weglika krzemu Zawartosc SiC\nZakres (0,10 – 99,0) %\nMetoda wagowa PN-86/H-04157 p. 3.2","categories":["other"],"row_index":21,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Silicon carbide, products containing silicon carbide SiC content Gravimetric method Range PN-86/H-04157 p. 3.2","parameters_zh":[{"name":"范围","range":"(0,10 – 99,0) %"}],"search_zh":"重量法 范围 PN-86/H-04157 p. 3.2","technique_zh":"重量法"},{"_id":"6a5dc9bbf1c10c8ce825dfe2","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Kruszywa","test_object_en":"Aggregates","methodology":"Zawartość chlorków rozpuszczalnych w wodzie","methodology_en":"Water-soluble chloride content","parameters":[{"name":"Zakres","range":"(0,001 – 0,700) %"}],"parameters_en":[{"name":"Range","range":"(0,001 – 0,700) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Zawartość chlorków rozpuszczalnych w wodzie\nZakres (0,001 – 0,700) %\nMetoda miareczkowa","reference":"PN-EN 1744-1+A1:2013-05 p.7","norm_bases":["PN-EN 1744-1+A1:2013-05 p.7"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywa Zawartość chlorków rozpuszczalnych w wodzie\nZakres (0,001 – 0,700) %\nMetoda miareczkowa PN-EN 1744-1+A1:2013-05 p.7 Kruszywa Zawartosc chlorkow rozpuszczalnych w wodzie\nZakres (0,001 – 0,700) %\nMetoda miareczkowa PN-EN 1744-1+A1:2013-05 p.7","categories":["other"],"row_index":22,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Aggregates Water-soluble chloride content Titrimetric method Range PN-EN 1744-1+A1:2013-05 p.7","parameters_zh":[{"name":"范围","range":"(0,001 – 0,700) %"}],"search_zh":"骨料 水溶性氯化物含量 滴定法 范围 PN-EN 1744-1+A1:2013-05 p.7","technique_zh":"滴定法","test_object_zh":"骨料","methodology_zh":"水溶性氯化物含量"},{"_id":"6a5dc9bbf1c10c8ce825dfe3","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Kruszywa","test_object_en":"Aggregates","methodology":"Zawartość siarczanów rozpuszczalnych w wodzie","methodology_en":"Content of water-soluble sulfates","parameters":[{"name":"Zakres","range":"(0,01 – 1,00) %"}],"parameters_en":[{"name":"Range","range":"(0,01 – 1,00) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość siarczanów rozpuszczalnych w wodzie\nZakres (0,01 – 1,00) %\nMetoda wagowa","reference":"PN-EN 1744-1+A1:2013-05 p.10","norm_bases":["PN-EN 1744-1+A1:2013-05 p.10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywa Zawartość siarczanów rozpuszczalnych w wodzie\nZakres (0,01 – 1,00) %\nMetoda wagowa PN-EN 1744-1+A1:2013-05 p.10 Kruszywa Zawartosc siarczanow rozpuszczalnych w wodzie\nZakres (0,01 – 1,00) %\nMetoda wagowa PN-EN 1744-1+A1:2013-05 p.10","categories":["other"],"row_index":23,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Aggregates Content of water-soluble sulfates Gravimetric method Range PN-EN 1744-1+A1:2013-05 p.10","parameters_zh":[{"name":"范围","range":"(0,01 – 1,00) %"}],"search_zh":"骨料 重量法 范围 PN-EN 1744-1+A1:2013-05 p.10","technique_zh":"重量法","test_object_zh":"骨料"},{"_id":"6a5dc9bbf1c10c8ce825dfe4","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Kruszywa","test_object_en":"Aggregates","methodology":"Zawartość siarki całkowitej","methodology_en":"Total sulfur content","parameters":[{"name":"Zakres","range":"(0,1 – 3,0) %"}],"parameters_en":[{"name":"Range","range":"(0,1 – 3,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość siarki całkowitej\nZakres (0,1 – 3,0) %\nMetoda wagowa","reference":"PN-EN 1744-1+A1:2013-05 p.11","norm_bases":["PN-EN 1744-1+A1:2013-05 p.11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywa Zawartość siarki całkowitej\nZakres (0,1 – 3,0) %\nMetoda wagowa PN-EN 1744-1+A1:2013-05 p.11 Kruszywa Zawartosc siarki calkowitej\nZakres (0,1 – 3,0) %\nMetoda wagowa PN-EN 1744-1+A1:2013-05 p.11","categories":["other"],"row_index":24,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Aggregates Total sulfur content Gravimetric method Range PN-EN 1744-1+A1:2013-05 p.11","methodology_zh":"全硫含量","parameters_zh":[{"name":"范围","range":"(0,1 – 3,0) %"}],"search_zh":"骨料 全硫含量 重量法 范围 PN-EN 1744-1+A1:2013-05 p.11","technique_zh":"重量法","test_object_zh":"骨料"},{"_id":"6a5dc9bbf1c10c8ce825dfe5","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Kruszywa","test_object_en":"Aggregates","methodology":"Zawartość siarczanów rozpuszczalnych w kwasie","methodology_en":"Content of acid-soluble sulfates","parameters":[{"name":"Zakres","range":"(0,1 – 6,0) %"}],"parameters_en":[{"name":"Range","range":"(0,1 – 6,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość siarczanów rozpuszczalnych w kwasie\nZakres (0,1 – 6,0) %\nMetoda wagowa","reference":"PN-EN 1744-1+A1:2013-05 p.12","norm_bases":["PN-EN 1744-1+A1:2013-05 p.12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywa Zawartość siarczanów rozpuszczalnych w kwasie\nZakres (0,1 – 6,0) %\nMetoda wagowa PN-EN 1744-1+A1:2013-05 p.12 Kruszywa Zawartosc siarczanow rozpuszczalnych w kwasie\nZakres (0,1 – 6,0) %\nMetoda wagowa PN-EN 1744-1+A1:2013-05 p.12","categories":["other"],"row_index":25,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Aggregates Content of acid-soluble sulfates Gravimetric method Range PN-EN 1744-1+A1:2013-05 p.12","parameters_zh":[{"name":"范围","range":"(0,1 – 6,0) %"}],"search_zh":"骨料 重量法 范围 PN-EN 1744-1+A1:2013-05 p.12","technique_zh":"重量法","test_object_zh":"骨料"},{"_id":"6a5dc9bbf1c10c8ce825dfe6","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Kruszywa","test_object_en":"Aggregates","methodology":"Zawartość zanieczyszczeń lekkich","methodology_en":"Content of light impurities","parameters":[{"name":"Zakres","range":"od 0,1 %"}],"parameters_en":[{"name":"Range","range":"od 0,1 %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość zanieczyszczeń lekkich\nZakres od 0,1 %\nMetoda wagowa","reference":"PN-EN 1744-1+A1:2013-05 p.14.2","norm_bases":["PN-EN 1744-1+A1:2013-05 p.14.2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywa Zawartość zanieczyszczeń lekkich\nZakres od 0,1 %\nMetoda wagowa PN-EN 1744-1+A1:2013-05 p.14.2 Kruszywa Zawartosc zanieczyszczen lekkich\nZakres od 0,1 %\nMetoda wagowa PN-EN 1744-1+A1:2013-05 p.14.2","categories":["other"],"row_index":26,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Aggregates Content of light impurities Gravimetric method Range PN-EN 1744-1+A1:2013-05 p.14.2","parameters_zh":[{"name":"范围","range":"od 0,1 %"}],"search_zh":"骨料 重量法 范围 PN-EN 1744-1+A1:2013-05 p.14.2","technique_zh":"重量法","test_object_zh":"骨料"},{"_id":"6a5dc9bbf1c10c8ce825dfe7","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Kruszywa","test_object_en":"Aggregates","methodology":"Obecność humusu","methodology_en":"Presence of humus","parameters":[],"parameters_en":[],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"technique_en":"Visual method","computed":[],"computed_en":[],"activity":"Obecność humusu\nMetoda wizualna","reference":"PN-EN 1744-1+A1:2013-05 p.15.1","norm_bases":["PN-EN 1744-1+A1:2013-05 p.15.1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywa Obecność humusu\nMetoda wizualna PN-EN 1744-1+A1:2013-05 p.15.1 Kruszywa Obecnosc humusu\nMetoda wizualna PN-EN 1744-1+A1:2013-05 p.15.1","categories":["other"],"row_index":27,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Aggregates Presence of humus Visual method PN-EN 1744-1+A1:2013-05 p.15.1","search_zh":"骨料 腐殖质的检出 目视法 PN-EN 1744-1+A1:2013-05 p.15.1","technique_zh":"目视法","test_object_zh":"骨料","methodology_zh":"腐殖质的检出"},{"_id":"6a5dc9bbf1c10c8ce825dfe8","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Kruszywa","test_object_en":"Aggregates","methodology":"Zawartość kwasu fulvo","methodology_en":"Fulvic acid content","parameters":[],"parameters_en":[],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"technique_en":"Visual method","computed":[],"computed_en":[],"activity":"Zawartość kwasu fulvo\nMetoda wizualna","reference":"PN-EN 1744-1+A1:2013-05 p.15.2","norm_bases":["PN-EN 1744-1+A1:2013-05 p.15.2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywa Zawartość kwasu fulvo\nMetoda wizualna PN-EN 1744-1+A1:2013-05 p.15.2 Kruszywa Zawartosc kwasu fulvo\nMetoda wizualna PN-EN 1744-1+A1:2013-05 p.15.2","categories":["other"],"row_index":28,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Aggregates Fulvic acid content Visual method PN-EN 1744-1+A1:2013-05 p.15.2","search_zh":"骨料 目视法 PN-EN 1744-1+A1:2013-05 p.15.2","technique_zh":"目视法","test_object_zh":"骨料"},{"_id":"6a5dc9bbf1c10c8ce825dfe9","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Kruszywa","test_object_en":"Aggregates","methodology":"Rozpuszczalność w wodzie","methodology_en":"Solubility in water","parameters":[{"name":"Zakres","range":"(0,1 – 10,0) %"}],"parameters_en":[{"name":"Range","range":"(0,1 – 10,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Rozpuszczalność w wodzie\nZakres (0,1 – 10,0) %\nMetoda wagowa","reference":"PN-EN 1744-1+A1:2013-05 p.16","norm_bases":["PN-EN 1744-1+A1:2013-05 p.16"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywa Rozpuszczalność w wodzie\nZakres (0,1 – 10,0) %\nMetoda wagowa PN-EN 1744-1+A1:2013-05 p.16 Kruszywa Rozpuszczalnosc w wodzie\nZakres (0,1 – 10,0) %\nMetoda wagowa PN-EN 1744-1+A1:2013-05 p.16","categories":["other"],"row_index":29,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Aggregates Solubility in water Gravimetric method Range PN-EN 1744-1+A1:2013-05 p.16","parameters_zh":[{"name":"范围","range":"(0,1 – 10,0) %"}],"search_zh":"骨料 重量法 范围 PN-EN 1744-1+A1:2013-05 p.16","technique_zh":"重量法","test_object_zh":"骨料"},{"_id":"6a5dc9bbf1c10c8ce825dfea","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Kruszywa","test_object_en":"Aggregates","methodology":"Straty przy prażeniu","methodology_en":"Loss on ignition","parameters":[{"name":"Zakres","range":"(0,01 – 52,0) %"}],"parameters_en":[{"name":"Range","range":"(0,01 – 52,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Straty przy prażeniu\nZakres (0,01 – 52,0) %\nMetoda wagowa","reference":"PN-EN 1744-1+A1:2013-05 p.17","norm_bases":["PN-EN 1744-1+A1:2013-05 p.17"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywa Straty przy prażeniu\nZakres (0,01 – 52,0) %\nMetoda wagowa PN-EN 1744-1+A1:2013-05 p.17 Kruszywa Straty przy prazeniu\nZakres (0,01 – 52,0) %\nMetoda wagowa PN-EN 1744-1+A1:2013-05 p.17","categories":["other"],"row_index":30,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Aggregates Loss on ignition Gravimetric method Range PN-EN 1744-1+A1:2013-05 p.17","parameters_zh":[{"name":"范围","range":"(0,01 – 52,0) %"}],"search_zh":"骨料 烧失量 重量法 范围 PN-EN 1744-1+A1:2013-05 p.17","technique_zh":"重量法","test_object_zh":"骨料","methodology_zh":"烧失量"},{"_id":"6a5dc9bbf1c10c8ce825dfeb","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Kruszywa","test_object_en":"Aggregates","methodology":"Rozpad krzemianu dwuwapniowego","methodology_en":"Dicalcium silicate disintegration","parameters":[],"parameters_en":[],"technique":"Metoda opisowa wizualna","techniques":["Metoda opisowa wizualna"],"technique_en":"Visual descriptive method","computed":[],"computed_en":[],"activity":"Rozpad krzemianu dwuwapniowego\nMetoda opisowa wizualna","reference":"PN-EN 1744-1+A1:2013-05 p.19.1","norm_bases":["PN-EN 1744-1+A1:2013-05 p.19.1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywa Rozpad krzemianu dwuwapniowego\nMetoda opisowa wizualna PN-EN 1744-1+A1:2013-05 p.19.1 Kruszywa Rozpad krzemianu dwuwapniowego\nMetoda opisowa wizualna PN-EN 1744-1+A1:2013-05 p.19.1","categories":["other"],"row_index":31,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Aggregates Dicalcium silicate disintegration Visual descriptive method PN-EN 1744-1+A1:2013-05 p.19.1","search_zh":"骨料 硅酸二钙分解 PN-EN 1744-1+A1:2013-05 p.19.1","test_object_zh":"骨料","methodology_zh":"硅酸二钙分解"},{"_id":"6a5dc9bbf1c10c8ce825dfec","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Kruszywa","test_object_en":"Aggregates","methodology":"Rozpad żelaza","methodology_en":"Iron disintegration","parameters":[],"parameters_en":[],"technique":"Metoda opisowa wizualna","techniques":["Metoda opisowa wizualna"],"technique_en":"Visual descriptive method","computed":[],"computed_en":[],"activity":"Rozpad żelaza\nMetoda opisowa wizualna","reference":"PN-EN 1744-1+A1:2013-05 p.19.2","norm_bases":["PN-EN 1744-1+A1:2013-05 p.19.2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywa Rozpad żelaza\nMetoda opisowa wizualna PN-EN 1744-1+A1:2013-05 p.19.2 Kruszywa Rozpad zelaza\nMetoda opisowa wizualna PN-EN 1744-1+A1:2013-05 p.19.2","categories":["other"],"row_index":32,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Aggregates Iron disintegration Visual descriptive method PN-EN 1744-1+A1:2013-05 p.19.2","search_zh":"骨料 PN-EN 1744-1+A1:2013-05 p.19.2","test_object_zh":"骨料"},{"_id":"6a5dc9bbf1c10c8ce825dfed","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Kruszywa","test_object_en":"Aggregates","methodology":"Reaktywność alkaliczna","methodology_en":"Alkali reactivity","parameters":[],"parameters_en":[],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Reaktywność alkaliczna\nMetoda wagowa","reference":"PN-B-06714/46:1992","norm_bases":["PN-B-06714/46:1992"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywa Reaktywność alkaliczna\nMetoda wagowa PN-B-06714/46:1992 Kruszywa Reaktywnosc alkaliczna\nMetoda wagowa PN-B-06714/46:1992","categories":["other"],"row_index":33,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Aggregates Alkali reactivity Gravimetric method PN-B-06714/46:1992","search_zh":"骨料 碱活性 重量法 PN-B-06714/46:1992","technique_zh":"重量法","test_object_zh":"骨料","methodology_zh":"碱活性"},{"_id":"6a5dc9bbf1c10c8ce825dfee","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Kruszywa","test_object_en":"Aggregates","methodology":"Zawartość drobnych cząstek – badanie błękitem metylenowym","methodology_en":"Fines content – methylene blue test","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość drobnych cząstek – badanie błękitem metylenowym","reference":"PN-EN 933-9:2022-07","norm_bases":["PN-EN 933-9:2022-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywa Zawartość drobnych cząstek – badanie błękitem metylenowym PN-EN 933-9:2022-07 Kruszywa Zawartosc drobnych czastek – badanie blekitem metylenowym PN-EN 933-9:2022-07","categories":["other"],"row_index":34,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Aggregates Fines content – methylene blue test PN-EN 933-9:2022-07","search_zh":"骨料 细颗粒含量 － 亚甲蓝试验 PN-EN 933-9:2022-07","test_object_zh":"骨料","methodology_zh":"细颗粒含量 － 亚甲蓝试验"},{"_id":"6a5dc9bbf1c10c8ce825dfef","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Kruszywa","test_object_en":"Aggregates","methodology":"Gęstość ziaren i nasiąkliwość","methodology_en":"Particle density and water absorption","parameters":[{"name":"Zakres","range":"(0,063 – 31,5) mm"}],"parameters_en":[{"name":"Range","range":"(0,063 – 31,5) mm"}],"technique":"Metoda piknometryczna","techniques":["Metoda piknometryczna"],"technique_en":"Pycnometric method","computed":[],"computed_en":[],"activity":"Gęstość ziaren i nasiąkliwość\nZakres (0,063 – 31,5) mm\nMetoda piknometryczna","reference":"PN-EN 1097-6:2022-07","norm_bases":["PN-EN 1097-6:2022-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywa Gęstość ziaren i nasiąkliwość\nZakres (0,063 – 31,5) mm\nMetoda piknometryczna PN-EN 1097-6:2022-07 Kruszywa Gestosc ziaren i nasiakliwosc\nZakres (0,063 – 31,5) mm\nMetoda piknometryczna PN-EN 1097-6:2022-07","categories":["other"],"row_index":35,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Aggregates Particle density and water absorption Pycnometric method Range PN-EN 1097-6:2022-07","parameters_zh":[{"name":"范围","range":"(0,063 – 31,5) mm"}],"search_zh":"骨料 颗粒密度与吸水率 比重瓶法 范围 PN-EN 1097-6:2022-07","test_object_zh":"骨料","technique_zh":"比重瓶法","methodology_zh":"颗粒密度与吸水率"},{"_id":"6a5dc9bbf1c10c8ce825dff0","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Kruszywa","test_object_en":"Aggregates","methodology":"Właściwości cieplne i odporność na działanie czynników atmosferycznych, Badanie w siarczanie magnezu","methodology_en":"Thermal properties and resistance to weathering, Magnesium sulfate test","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Właściwości cieplne i odporność na działanie czynników atmosferycznych, Badanie w siarczanie magnezu","reference":"PN-EN 1367-2:2010","norm_bases":["PN-EN 1367-2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywa Właściwości cieplne i odporność na działanie czynników atmosferycznych, Badanie w siarczanie magnezu PN-EN 1367-2:2010 Kruszywa Wlasciwosci cieplne i odpornosc na dzialanie czynnikow atmosferycznych, Badanie w siarczanie magnezu PN-EN 1367-2:2010","categories":["other"],"row_index":36,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Aggregates Thermal properties and resistance to weathering, Magnesium sulfate test PN-EN 1367-2:2010","search_zh":"骨料 PN-EN 1367-2:2010","test_object_zh":"骨料"},{"_id":"6a5dc9bbf1c10c8ce825dff1","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Kruszywa","test_object_en":"Aggregates","methodology":"Właściwości cieplne i odporność na działanie czynników atmosferycznych, Badanie bazaltowej zgorzeli słonecznej metodą gotowania","methodology_en":"Thermal properties and resistance to weathering, Test for basalt sunburn (Sonnenbrand) by the boiling method","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Właściwości cieplne i odporność na działanie czynników atmosferycznych, Badanie bazaltowej zgorzeli słonecznej metodą gotowania","reference":"PN-EN 1367-3:2002+AC:2004","norm_bases":["PN-EN 1367-3:2002+AC:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywa Właściwości cieplne i odporność na działanie czynników atmosferycznych, Badanie bazaltowej zgorzeli słonecznej metodą gotowania PN-EN 1367-3:2002+AC:2004 Kruszywa Wlasciwosci cieplne i odpornosc na dzialanie czynnikow atmosferycznych, Badanie bazaltowej zgorzeli slonecznej metoda gotowania PN-EN 1367-3:2002+AC:2004","categories":["other"],"row_index":37,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Aggregates Thermal properties and resistance to weathering, Test for basalt sunburn (Sonnenbrand) by the boiling method PN-EN 1367-3:2002+AC:2004","search_zh":"骨料 PN-EN 1367-3:2002+AC:2004","test_object_zh":"骨料"},{"_id":"6a5dc9bbf1c10c8ce825dff2","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Kruszywa, Popioły lotne","test_object_en":"Aggregates, Fly ashes","methodology":"Gęstość wypełniacza","methodology_en":"Density of filler","parameters":[],"parameters_en":[],"technique":"Metoda piknometryczna","techniques":["Metoda piknometryczna"],"technique_en":"Pycnometric method","computed":[],"computed_en":[],"activity":"Gęstość wypełniacza\nMetoda piknometryczna","reference":"PN-EN 1097-7:2023-04","norm_bases":["PN-EN 1097-7:2023-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywa, Popioły lotne Gęstość wypełniacza\nMetoda piknometryczna PN-EN 1097-7:2023-04 Kruszywa, Popioly lotne Gestosc wypelniacza\nMetoda piknometryczna PN-EN 1097-7:2023-04","categories":["other"],"row_index":38,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Aggregates, Fly ashes Density of filler Pycnometric method PN-EN 1097-7:2023-04","search_zh":"比重瓶法 PN-EN 1097-7:2023-04","technique_zh":"比重瓶法"},{"_id":"6a5dc9bbf1c10c8ce825dff3","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Kruszywa wypełniające","test_object_en":"Filler aggregates","methodology":"Przyrost temperatury mięknienia mieszanki wypełniacz-asfalt","methodology_en":"Increase in softening point of the filler-bitumen mixture","parameters":[],"parameters_en":[],"technique":"Metoda pierścienia i kuli","techniques":["Metoda pierścienia i kuli"],"technique_en":"Ring and ball method","computed":[],"computed_en":[],"activity":"Przyrost temperatury mięknienia mieszanki wypełniacz-asfalt\nMetoda pierścienia i kuli","reference":"PN-EN 13179-1:2013-10","norm_bases":["PN-EN 13179-1:2013-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywa wypełniające Przyrost temperatury mięknienia mieszanki wypełniacz-asfalt\nMetoda pierścienia i kuli PN-EN 13179-1:2013-10 Kruszywa wypelniajace Przyrost temperatury mieknienia mieszanki wypelniacz-asfalt\nMetoda pierscienia i kuli PN-EN 13179-1:2013-10","categories":["other"],"row_index":39,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Filler aggregates Increase in softening point of the filler-bitumen mixture Ring and ball method PN-EN 13179-1:2013-10","search_zh":"环球法 PN-EN 13179-1:2013-10","technique_zh":"环球法"},{"_id":"6a5dc9bbf1c10c8ce825dff4","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Domieszki do betonu, zaprawy i zaczynu","test_object_en":"Admixtures for concrete, mortar and grout","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"ISO 4316:1977","norm_bases":["ISO 4316:1977"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Domieszki do betonu, zaprawy i zaczynu pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna ISO 4316:1977 Domieszki do betonu, zaprawy i zaczynu pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna ISO 4316:1977","categories":["construction"],"row_index":40,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Admixtures for concrete, mortar and grout pH Potentiometric method Range ISO 4316:1977","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"混凝土、砂浆与净浆用外加剂 pH 值 电位法 范围 ISO 4316:1977","technique_zh":"电位法","test_object_zh":"混凝土、砂浆与净浆用外加剂"},{"_id":"6a5dc9bbf1c10c8ce825dff5","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Domieszki do betonu, zaprawy i zaczynu","test_object_en":"Admixtures for concrete, mortar and grout","methodology":"Chlorki rozpuszczalne w wodzie","methodology_en":"Water-soluble chlorides","parameters":[{"name":"Zakres","range":"(0,01 – 0,50) %"}],"parameters_en":[{"name":"Range","range":"(0,01 – 0,50) %"}],"technique":"Metoda miareczkowania potencjometrycznego","techniques":["Metoda miareczkowania potencjometrycznego"],"technique_en":"Potentiometric titration method","computed":[],"computed_en":[],"activity":"Chlorki rozpuszczalne w wodzie\nZakres (0,01 – 0,50) %\nMetoda miareczkowania potencjometrycznego","reference":"PN-EN 480-10:2011","norm_bases":["PN-EN 480-10:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Domieszki do betonu, zaprawy i zaczynu Chlorki rozpuszczalne w wodzie\nZakres (0,01 – 0,50) %\nMetoda miareczkowania potencjometrycznego PN-EN 480-10:2011 Domieszki do betonu, zaprawy i zaczynu Chlorki rozpuszczalne w wodzie\nZakres (0,01 – 0,50) %\nMetoda miareczkowania potencjometrycznego PN-EN 480-10:2011","categories":["construction"],"row_index":41,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Admixtures for concrete, mortar and grout Water-soluble chlorides Potentiometric titration method Range PN-EN 480-10:2011","parameters_zh":[{"name":"范围","range":"(0,01 – 0,50) %"}],"search_zh":"混凝土、砂浆与净浆用外加剂 电位滴定法 范围 PN-EN 480-10:2011","technique_zh":"电位滴定法","test_object_zh":"混凝土、砂浆与净浆用外加剂"},{"_id":"6a5dc9bbf1c10c8ce825dff6","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Domieszki do betonu, zaprawy i zaczynu","test_object_en":"Admixtures for concrete, mortar and grout","methodology":"Umowna zawartość suchej substancji","methodology_en":"Conventional dry matter content","parameters":[{"name":"Zakres","range":"(1,0 – 40,0) %"}],"parameters_en":[{"name":"Range","range":"(1,0 – 40,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Umowna zawartość suchej substancji\nZakres (1,0 – 40,0) %\nMetoda wagowa","reference":"PN-EN 480-8:2012","norm_bases":["PN-EN 480-8:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Domieszki do betonu, zaprawy i zaczynu Umowna zawartość suchej substancji\nZakres (1,0 – 40,0) %\nMetoda wagowa PN-EN 480-8:2012 Domieszki do betonu, zaprawy i zaczynu Umowna zawartosc suchej substancji\nZakres (1,0 – 40,0) %\nMetoda wagowa PN-EN 480-8:2012","categories":["construction"],"row_index":42,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Admixtures for concrete, mortar and grout Conventional dry matter content Gravimetric method Range PN-EN 480-8:2012","parameters_zh":[{"name":"范围","range":"(1,0 – 40,0) %"}],"search_zh":"混凝土、砂浆与净浆用外加剂 约定干物质含量 重量法 范围 PN-EN 480-8:2012","technique_zh":"重量法","methodology_zh":"约定干物质含量","test_object_zh":"混凝土、砂浆与净浆用外加剂"},{"_id":"6a5dc9bbf1c10c8ce825dff7","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Domieszki do betonu, zaprawy i zaczynu","test_object_en":"Admixtures for concrete, mortar and grout","methodology":"Gęstość","methodology_en":"Density","parameters":[{"name":"Zakres","range":"(1,00 – 1,20) g/cm3"}],"parameters_en":[{"name":"Range","range":"(1,00 – 1,20) g/cm3"}],"technique":"Metoda piknometryczna","techniques":["Metoda piknometryczna"],"technique_en":"Pycnometric method","computed":[],"computed_en":[],"activity":"Gęstość\nZakres (1,00 – 1,20) g/cm3\nMetoda piknometryczna","reference":"ISO 758:1976","norm_bases":["ISO 758:1976"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Domieszki do betonu, zaprawy i zaczynu Gęstość\nZakres (1,00 – 1,20) g/cm3\nMetoda piknometryczna ISO 758:1976 Domieszki do betonu, zaprawy i zaczynu Gestosc\nZakres (1,00 – 1,20) g/cm3\nMetoda piknometryczna ISO 758:1976","categories":["construction"],"row_index":43,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Admixtures for concrete, mortar and grout Density Pycnometric method Range ISO 758:1976","methodology_zh":"密度","parameters_zh":[{"name":"范围","range":"(1,00 – 1,20) g/cm3"}],"search_zh":"混凝土、砂浆与净浆用外加剂 密度 比重瓶法 范围 ISO 758:1976","technique_zh":"比重瓶法","test_object_zh":"混凝土、砂浆与净浆用外加剂"},{"_id":"6a5dc9bbf1c10c8ce825dff8","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Materiały budowlane: kruszywo, popiół lotny, spoiwa mineralno- cementowe (wyciągi wodne), Gleby, grunty (wyciągi wodne), Odpady: kod 17 05 04, 20 02 02, 19 12 09 (wyciągi wodne)","test_object_en":"Building materials: aggregate, fly ash, mineral-cement binders (aqueous extracts), Soils, ground (aqueous extracts), Waste: code 17 05 04, 20 02 02, 19 12 09 (aqueous extracts)","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"2,0 – 13,0"}],"parameters_en":[{"name":"Range","range":"2,0 – 13,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 2,0 – 13,0\nMetoda potencjometryczna","reference":"PN-EN 12457-2:2006 | PN-EN 12457-4:2006 | PN-EN ISO 10523:2012","norm_bases":["PN-EN 12457-2:2006","PN-EN 12457-4:2006","PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały budowlane: kruszywo, popiół lotny, spoiwa mineralno- cementowe (wyciągi wodne), Gleby, grunty (wyciągi wodne), Odpady: kod 17 05 04, 20 02 02, 19 12 09 (wyciągi wodne) pH\nZakres 2,0 – 13,0\nMetoda potencjometryczna PN-EN 12457-2:2006 | PN-EN 12457-4:2006 | PN-EN ISO 10523:2012 Materialy budowlane: kruszywo, popiol lotny, spoiwa mineralno- cementowe (wyciagi wodne), Gleby, grunty (wyciagi wodne), Odpady: kod 17 05 04, 20 02 02, 19 12 09 (wyciagi wodne) pH\nZakres 2,0 – 13,0\nMetoda potencjometryczna PN-EN 12457-2:2006 | PN-EN 12457-4:2006 | PN-EN ISO 10523:2012","categories":["construction","materials","environment"],"row_index":44,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Building materials: aggregate, fly ash, mineral-cement binders (aqueous extracts), Soils, ground (aqueous extracts), Waste: code 17 05 04, 20 02 02, 19 12 09 (aqueous extracts) pH Potentiometric method Range PN-EN 12457-2:2006 | PN-EN 12457-4:2006 | PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 13,0"}],"search_zh":"pH 值 电位法 范围 PN-EN 12457-2:2006 | PN-EN 12457-4:2006 | PN-EN ISO 10523:2012","technique_zh":"电位法"},{"_id":"6a5dc9bbf1c10c8ce825dff9","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Materiały budowlane: kruszywo, popiół lotny, spoiwa mineralno- cementowe (wyciągi wodne), Gleby, grunty (wyciągi wodne), Odpady: kod 17 05 04, 20 02 02, 19 12 09 (wyciągi wodne)","test_object_en":"Building materials: aggregate, fly ash, mineral-cement binders (aqueous extracts), Soils, ground (aqueous extracts), Waste: code 17 05 04, 20 02 02, 19 12 09 (aqueous extracts)","methodology":"Stężenie i zawartość pierwiastków","methodology_en":"Element concentration and content","parameters":[{"name":"As","range":"(0,023 – 0,700) mg/l"},{"name":"Zakres","range":"(0,23 – 7,00) mg/kg"},{"name":"Ba","range":"(0,0010 – 4,20) mg/l"},{"name":"(0,010 – 42,0) mg/kg"},{"name":"Cd","range":"(0,0010 – 0,300) mg/l"},{"name":"(0,010 – 3,00) mg/kg"},{"name":"Cr całk.","range":"(0,0060 – 0,500) mg/l"},{"name":"(0,060 – 5,00) mg/kg"},{"name":"Cu","range":"(0,0090 – 0,800) mg/l"},{"name":"(0,090 – 8,00) mg/kg"},{"name":"Mo","range":"(0,0060 – 0,800) mg/l"},{"name":"(0,060 – 8,00) mg/kg"},{"name":"Ni","range":"(0,0080 – 0,800) mg/l"},{"name":"(0,080 – 8,00) mg/kg"},{"name":"Pb","range":"(0,021 – 2,80) mg/l"},{"name":"(0,21 – 28,0) mg/kg"},{"name":"Sb","range":"(0,038 – 0,600) mg/l"},{"name":"(0,38 – 6,00) mg/kg"},{"name":"Se","range":"(0,037 – 0,200) mg/l"},{"name":"(0,37 – 2,00) mg/kg"},{"name":"Zn","range":"(0,022 – 0,900) mg/l"},{"name":"(0,22 – 9,00) mg/kg"}],"parameters_en":[{"name":"As","range":"(0,023 – 0,700) mg/l"},{"name":"Range","range":"(0,23 – 7,00) mg/kg"},{"name":"Ba","range":"(0,0010 – 4,20) mg/l"},{"name":"(0,010 – 42,0) mg/kg"},{"name":"Cd","range":"(0,0010 – 0,300) mg/l"},{"name":"(0,010 – 3,00) mg/kg"},{"name":"Cr total","range":"(0,0060 – 0,500) mg/l"},{"name":"(0,060 – 5,00) mg/kg"},{"name":"Cu","range":"(0,0090 – 0,800) mg/l"},{"name":"(0,090 – 8,00) mg/kg"},{"name":"Mo","range":"(0,0060 – 0,800) mg/l"},{"name":"(0,060 – 8,00) mg/kg"},{"name":"Ni","range":"(0,0080 – 0,800) mg/l"},{"name":"(0,080 – 8,00) mg/kg"},{"name":"Pb","range":"(0,021 – 2,80) mg/l"},{"name":"(0,21 – 28,0) mg/kg"},{"name":"Sb","range":"(0,038 – 0,600) mg/l"},{"name":"(0,38 – 6,00) mg/kg"},{"name":"Se","range":"(0,037 – 0,200) mg/l"},{"name":"(0,37 – 2,00) mg/kg"},{"name":"Zn","range":"(0,022 – 0,900) mg/l"},{"name":"(0,22 – 9,00) mg/kg"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","computed":[],"computed_en":[],"activity":"Stężenie i zawartość pierwiastków\nZakres:\nAs (0,023 – 0,700) mg/l\nZakres (0,23 – 7,00) mg/kg\nBa (0,0010 – 4,20) mg/l\n(0,010 – 42,0) mg/kg\nCd (0,0010 – 0,300) mg/l\n(0,010 – 3,00) mg/kg\nCr całk. (0,0060 – 0,500) mg/l\n(0,060 – 5,00) mg/kg\nCu (0,0090 – 0,800) mg/l\n(0,090 – 8,00) mg/kg\nMo (0,0060 – 0,800) mg/l\n(0,060 – 8,00) mg/kg\nNi (0,0080 – 0,800) mg/l\n(0,080 – 8,00) mg/kg\nPb (0,021 – 2,80) mg/l\n(0,21 – 28,0) mg/kg\nSb (0,038 – 0,600) mg/l\n(0,38 – 6,00) mg/kg\nSe (0,037 – 0,200) mg/l\n(0,37 – 2,00) mg/kg\nZn (0,022 – 0,900) mg/l\n(0,22 – 9,00) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN 12457-2:2006 | PN-EN 12457-4:2006 | PN-EN ISO 11885:2009","norm_bases":["PN-EN 12457-2:2006","PN-EN 12457-4:2006","PN-EN ISO 11885:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały budowlane: kruszywo, popiół lotny, spoiwa mineralno- cementowe (wyciągi wodne), Gleby, grunty (wyciągi wodne), Odpady: kod 17 05 04, 20 02 02, 19 12 09 (wyciągi wodne) Stężenie i zawartość pierwiastków\nZakres:\nAs (0,023 – 0,700) mg/l\nZakres (0,23 – 7,00) mg/kg\nBa (0,0010 – 4,20) mg/l\n(0,010 – 42,0) mg/kg\nCd (0,0010 – 0,300) mg/l\n(0,010 – 3,00) mg/kg\nCr całk. (0,0060 – 0,500) mg/l\n(0,060 – 5,00) mg/kg\nCu (0,0090 – 0,800) mg/l\n(0,090 – 8,00) mg/kg\nMo (0,0060 – 0,800) mg/l\n(0,060 – 8,00) mg/kg\nNi (0,0080 – 0,800) mg/l\n(0,080 – 8,00) mg/kg\nPb (0,021 – 2,80) mg/l\n(0,21 – 28,0) mg/kg\nSb (0,038 – 0,600) mg/l\n(0,38 – 6,00) mg/kg\nSe (0,037 – 0,200) mg/l\n(0,37 – 2,00) mg/kg\nZn (0,022 – 0,900) mg/l\n(0,22 – 9,00) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN 12457-2:2006 | PN-EN 12457-4:2006 | PN-EN ISO 11885:2009 Materialy budowlane: kruszywo, popiol lotny, spoiwa mineralno- cementowe (wyciagi wodne), Gleby, grunty (wyciagi wodne), Odpady: kod 17 05 04, 20 02 02, 19 12 09 (wyciagi wodne) Stezenie i zawartosc pierwiastkow\nZakres:\nAs (0,023 – 0,700) mg/l\nZakres (0,23 – 7,00) mg/kg\nBa (0,0010 – 4,20) mg/l\n(0,010 – 42,0) mg/kg\nCd (0,0010 – 0,300) mg/l\n(0,010 – 3,00) mg/kg\nCr calk. (0,0060 – 0,500) mg/l\n(0,060 – 5,00) mg/kg\nCu (0,0090 – 0,800) mg/l\n(0,090 – 8,00) mg/kg\nMo (0,0060 – 0,800) mg/l\n(0,060 – 8,00) mg/kg\nNi (0,0080 – 0,800) mg/l\n(0,080 – 8,00) mg/kg\nPb (0,021 – 2,80) mg/l\n(0,21 – 28,0) mg/kg\nSb (0,038 – 0,600) mg/l\n(0,38 – 6,00) mg/kg\nSe (0,037 – 0,200) mg/l\n(0,37 – 2,00) mg/kg\nZn (0,022 – 0,900) mg/l\n(0,22 – 9,00) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN 12457-2:2006 | PN-EN 12457-4:2006 | PN-EN ISO 11885:2009","categories":["construction","materials","environment"],"row_index":45,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Building materials: aggregate, fly ash, mineral-cement binders (aqueous extracts), Soils, ground (aqueous extracts), Waste: code 17 05 04, 20 02 02, 19 12 09 (aqueous extracts) Element concentration and content Inductively coupled plasma optical emission spectrometry (ICP-OES) As Range Ba (0,010 – 42,0) mg/kg Cd (0,010 – 3,00) mg/kg Cr total (0,060 – 5,00) mg/kg Cu (0,090 – 8,00) mg/kg Mo (0,060 – 8,00) mg/kg Ni (0,080 – 8,00) mg/kg Pb (0,21 – 28,0) mg/kg Sb (0,38 – 6,00) mg/kg Se (0,37 – 2,00) mg/kg Zn (0,22 – 9,00) mg/kg PN-EN 12457-2:2006 | PN-EN 12457-4:2006 | PN-EN ISO 11885:2009","parameters_zh":[{"name":"As","range":"(0,023 – 0,700) mg/l"},{"name":"范围","range":"(0,23 – 7,00) mg/kg"},{"name":"Ba","range":"(0,0010 – 4,20) mg/l"},{"name":"(0,010 – 42,0) mg/kg"},{"name":"Cd","range":"(0,0010 – 0,300) mg/l"},{"name":"(0,010 – 3,00) mg/kg"},{"name":"Cr całk.","range":"(0,0060 – 0,500) mg/l"},{"name":"(0,060 – 5,00) mg/kg"},{"name":"Cu","range":"(0,0090 – 0,800) mg/l"},{"name":"(0,090 – 8,00) mg/kg"},{"name":"Mo","range":"(0,0060 – 0,800) mg/l"},{"name":"(0,060 – 8,00) mg/kg"},{"name":"Ni","range":"(0,0080 – 0,800) mg/l"},{"name":"(0,080 – 8,00) mg/kg"},{"name":"Pb","range":"(0,021 – 2,80) mg/l"},{"name":"(0,21 – 28,0) mg/kg"},{"name":"Sb","range":"(0,038 – 0,600) mg/l"},{"name":"(0,38 – 6,00) mg/kg"},{"name":"Se","range":"(0,037 – 0,200) mg/l"},{"name":"(0,37 – 2,00) mg/kg"},{"name":"Zn","range":"(0,022 – 0,900) mg/l"},{"name":"(0,22 – 9,00) mg/kg"}],"search_zh":"元素的浓度与含量 电感耦合等离子体原子发射光谱法（ICP-OES） As 范围 Ba Cd Cu Mo Ni Pb Sb Se Zn PN-EN 12457-2:2006 | PN-EN 12457-4:2006 | PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","methodology_zh":"元素的浓度与含量"},{"_id":"6a5dc9bbf1c10c8ce825dffa","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-G-04502:2014-11 p. 5.3.3, 5.3.4","norm_bases":["PN-G-04502:2014-11 p. 5.3.3, 5.3.4"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Pobieranie próbek do badań chemicznych i fizycznych PN-G-04502:2014-11 p. 5.3.3, 5.3.4 Paliwa stale: wegiel kamienny Pobieranie probek do badan chemicznych i fizycznych PN-G-04502:2014-11 p. 5.3.3, 5.3.4","categories":["petro"],"row_index":46,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Sampling for chemical and physical testing PN-G-04502:2014-11 p. 5.3.3, 5.3.4","methodology_zh":"化学与物理检测用样品采集","search_zh":"固体燃料：烟煤 化学与物理检测用样品采集 PN-G-04502:2014-11 p. 5.3.3, 5.3.4","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5dc9bbf1c10c8ce825dffb","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wilgoci całkowitej","methodology_en":"Total moisture content","parameters":[{"name":"Zakres","range":"(1,0 – 27,0) %"}],"parameters_en":[{"name":"Range","range":"(1,0 – 27,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość wilgoci całkowitej\nZakres (1,0 – 27,0) %\nMetoda wagowa","reference":"PN-ISO 589:2006 met. B1","norm_bases":["PN-ISO 589:2006 met. B1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci całkowitej\nZakres (1,0 – 27,0) %\nMetoda wagowa PN-ISO 589:2006 met. B1 Paliwa stale: wegiel kamienny Zawartosc wilgoci calkowitej\nZakres (1,0 – 27,0) %\nMetoda wagowa PN-ISO 589:2006 met. B1","categories":["petro"],"row_index":47,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Total moisture content Gravimetric method Range PN-ISO 589:2006 met. B1","methodology_zh":"全水分含量","parameters_zh":[{"name":"范围","range":"(1,0 – 27,0) %"}],"search_zh":"固体燃料：烟煤 全水分含量 重量法 范围 PN-ISO 589:2006 met. B1","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5dc9bbf1c10c8ce825dffc","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wilgoci w próbce analitycznej","methodology_en":"Moisture content in the analytical sample","parameters":[{"name":"Zakres","range":"(0,6 – 11,0) %"}],"parameters_en":[{"name":"Range","range":"(0,6 – 11,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (0,6 – 11,0) %\nMetoda wagowa","reference":"PN-ISO 11722:2009","norm_bases":["PN-ISO 11722:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci w próbce analitycznej\nZakres (0,6 – 11,0) %\nMetoda wagowa PN-ISO 11722:2009 Paliwa stale: wegiel kamienny Zawartosc wilgoci w probce analitycznej\nZakres (0,6 – 11,0) %\nMetoda wagowa PN-ISO 11722:2009","categories":["petro"],"row_index":48,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Moisture content in the analytical sample Gravimetric method Range PN-ISO 11722:2009","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(0,6 – 11,0) %"}],"search_zh":"固体燃料：烟煤 分析样品水分含量 重量法 范围 PN-ISO 11722:2009","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5dc9bbf1c10c8ce825dffd","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny, koks","test_object_en":"Solid fuels: hard coal, coke","methodology":"Zawartość wilgoci całkowitej","methodology_en":"Total moisture content","parameters":[{"name":"Zakres","range":"(0,1 – 27,0) %"}],"parameters_en":[{"name":"Range","range":"(0,1 – 27,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość wilgoci całkowitej\nZakres (0,1 – 27,0) %\nMetoda wagowa","reference":"PN-G-04611:2020-06","norm_bases":["PN-G-04611:2020-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny, koks Zawartość wilgoci całkowitej\nZakres (0,1 – 27,0) %\nMetoda wagowa PN-G-04611:2020-06 Paliwa stale: wegiel kamienny, koks Zawartosc wilgoci calkowitej\nZakres (0,1 – 27,0) %\nMetoda wagowa PN-G-04611:2020-06","categories":["petro"],"row_index":49,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal, coke Total moisture content Gravimetric method Range PN-G-04611:2020-06","methodology_zh":"全水分含量","parameters_zh":[{"name":"范围","range":"(0,1 – 27,0) %"}],"search_zh":"固体燃料：烟煤、焦炭 全水分含量 重量法 范围 PN-G-04611:2020-06","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤、焦炭"},{"_id":"6a5dc9bbf1c10c8ce825dffe","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny, koks","test_object_en":"Solid fuels: hard coal, coke","methodology":"Zawartość wilgoci w próbce analitycznej","methodology_en":"Moisture content in the analytical sample","parameters":[{"name":"Zakres","range":"(0,1 – 15,0) %"}],"parameters_en":[{"name":"Range","range":"(0,1 – 15,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (0,1 – 15,0) %\nMetoda wagowa","reference":"PN-G-04611:2020-06","norm_bases":["PN-G-04611:2020-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny, koks Zawartość wilgoci w próbce analitycznej\nZakres (0,1 – 15,0) %\nMetoda wagowa PN-G-04611:2020-06 Paliwa stale: wegiel kamienny, koks Zawartosc wilgoci w probce analitycznej\nZakres (0,1 – 15,0) %\nMetoda wagowa PN-G-04611:2020-06","categories":["petro"],"row_index":50,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal, coke Moisture content in the analytical sample Gravimetric method Range PN-G-04611:2020-06","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(0,1 – 15,0) %"}],"search_zh":"固体燃料：烟煤、焦炭 分析样品水分含量 重量法 范围 PN-G-04611:2020-06","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤、焦炭"},{"_id":"6a5dc9bbf1c10c8ce825dfff","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny, koks","test_object_en":"Solid fuels: hard coal, coke","methodology":"Zawartość wilgoci przemijającej","methodology_en":"Free moisture content","parameters":[{"name":"Zakres","range":"(7,0 – 23,0) %"}],"parameters_en":[{"name":"Range","range":"(7,0 – 23,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość wilgoci przemijającej\nZakres (7,0 – 23,0) %\nMetoda wagowa","reference":"PN-G-04611:2020-06","norm_bases":["PN-G-04611:2020-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny, koks Zawartość wilgoci przemijającej\nZakres (7,0 – 23,0) %\nMetoda wagowa PN-G-04611:2020-06 Paliwa stale: wegiel kamienny, koks Zawartosc wilgoci przemijajacej\nZakres (7,0 – 23,0) %\nMetoda wagowa PN-G-04611:2020-06","categories":["petro"],"row_index":51,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal, coke Free moisture content Gravimetric method Range PN-G-04611:2020-06","parameters_zh":[{"name":"范围","range":"(7,0 – 23,0) %"}],"search_zh":"固体燃料：烟煤、焦炭 外在水分含量 重量法 范围 PN-G-04611:2020-06","technique_zh":"重量法","methodology_zh":"外在水分含量","test_object_zh":"固体燃料：烟煤、焦炭"},{"_id":"6a5dc9bbf1c10c8ce825e000","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny, koks","test_object_en":"Solid fuels: hard coal, coke","methodology":"Zawartość popiołu","methodology_en":"Ash content","parameters":[{"name":"Zakres","range":"(1,0 – 25,0) %"}],"parameters_en":[{"name":"Range","range":"(1,0 – 25,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość popiołu\nZakres (1,0 – 25,0) %\nMetoda wagowa","reference":"PN-ISO 1171:2002","norm_bases":["PN-ISO 1171:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny, koks Zawartość popiołu\nZakres (1,0 – 25,0) %\nMetoda wagowa PN-ISO 1171:2002 Paliwa stale: wegiel kamienny, koks Zawartosc popiolu\nZakres (1,0 – 25,0) %\nMetoda wagowa PN-ISO 1171:2002","categories":["petro"],"row_index":52,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal, coke Ash content Gravimetric method Range PN-ISO 1171:2002","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(1,0 – 25,0) %"}],"search_zh":"固体燃料：烟煤、焦炭 灰分含量 重量法 范围 PN-ISO 1171:2002","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤、焦炭"},{"_id":"6a5dc9bbf1c10c8ce825e001","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny, koks","test_object_en":"Solid fuels: hard coal, coke","methodology":"Ciepło spalania","methodology_en":"Gross calorific value","parameters":[{"name":"Zakres","range":"(15 000 – 36 000) kJ/kg"},{"name":"Wartość opałowa (z obliczeń)"}],"parameters_en":[{"name":"Range","range":"(15 000 – 36 000) kJ/kg"},{"name":"Net calorific value (calculated)"}],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna"],"technique_en":"Calorimetric method","computed":[],"computed_en":[],"activity":"Ciepło spalania\nZakres:\nZakres (15 000 – 36 000) kJ/kg\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna","reference":"PN-ISO 1928:2020-05","norm_bases":["PN-ISO 1928:2020-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny, koks Ciepło spalania\nZakres:\nZakres (15 000 – 36 000) kJ/kg\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna PN-ISO 1928:2020-05 Paliwa stale: wegiel kamienny, koks Cieplo spalania\nZakres:\nZakres (15 000 – 36 000) kJ/kg\nWartosc opalowa (z obliczen)\nMetoda kalorymetryczna PN-ISO 1928:2020-05","categories":["petro"],"row_index":53,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal, coke Gross calorific value Calorimetric method Range Net calorific value (calculated) PN-ISO 1928:2020-05","methodology_zh":"高位发热量","parameters_zh":[{"name":"范围","range":"(15 000 – 36 000) kJ/kg"},{"name":"低位发热量（计算值）"}],"search_zh":"固体燃料：烟煤、焦炭 高位发热量 量热法 范围 低位发热量（计算值） PN-ISO 1928:2020-05","technique_zh":"量热法","test_object_zh":"固体燃料：烟煤、焦炭"},{"_id":"6a5dc9bbf1c10c8ce825e002","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny, koks","test_object_en":"Solid fuels: hard coal, coke","methodology":"Zawartość części lotnych","methodology_en":"Volatile matter content","parameters":[{"name":"Zakres","range":"(1,00 – 30,00) %"}],"parameters_en":[{"name":"Range","range":"(1,00 – 30,00) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość części lotnych\nZakres (1,00 – 30,00) %\nMetoda wagowa","reference":"PN-G-04516:1998","norm_bases":["PN-G-04516:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny, koks Zawartość części lotnych\nZakres (1,00 – 30,00) %\nMetoda wagowa PN-G-04516:1998 Paliwa stale: wegiel kamienny, koks Zawartosc czesci lotnych\nZakres (1,00 – 30,00) %\nMetoda wagowa PN-G-04516:1998","categories":["petro"],"row_index":54,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal, coke Volatile matter content Gravimetric method Range PN-G-04516:1998","parameters_zh":[{"name":"范围","range":"(1,00 – 30,00) %"}],"search_zh":"固体燃料：烟煤、焦炭 挥发分含量 重量法 范围 PN-G-04516:1998","technique_zh":"重量法","methodology_zh":"挥发分含量","test_object_zh":"固体燃料：烟煤、焦炭"},{"_id":"6a5dc9bbf1c10c8ce825e003","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny, koks","test_object_en":"Solid fuels: hard coal, coke","methodology":"Zawartość wilgoci analitycznej","methodology_en":"Analytical moisture content","parameters":[{"name":"Zakres","range":"(0,10 – 20,00) %"},{"name":"Zawartość popiołu"},{"name":"Zakres","range":"(0,10 – 50,00) %"}],"parameters_en":[{"name":"Range","range":"(0,10 – 20,00) %"},{"name":"Ash content"},{"name":"Range","range":"(0,10 – 50,00) %"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)"],"technique_en":"Thermogravimetric method (TGA)","computed":[],"computed_en":[],"activity":"Zawartość wilgoci analitycznej\nZakres:\nZakres (0,10 – 20,00) %\nZawartość popiołu\nZakres (0,10 – 50,00) %\nMetoda termograwimetryczna (TGA)","reference":"PN-G-04560:1998","norm_bases":["PN-G-04560:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny, koks Zawartość wilgoci analitycznej\nZakres:\nZakres (0,10 – 20,00) %\nZawartość popiołu\nZakres (0,10 – 50,00) %\nMetoda termograwimetryczna (TGA) PN-G-04560:1998 Paliwa stale: wegiel kamienny, koks Zawartosc wilgoci analitycznej\nZakres:\nZakres (0,10 – 20,00) %\nZawartosc popiolu\nZakres (0,10 – 50,00) %\nMetoda termograwimetryczna (TGA) PN-G-04560:1998","categories":["petro"],"row_index":55,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal, coke Analytical moisture content Thermogravimetric method (TGA) Range Ash content Range PN-G-04560:1998","parameters_zh":[{"name":"范围","range":"(0,10 – 20,00) %"},{"name":"灰分含量"},{"name":"范围","range":"(0,10 – 50,00) %"}],"search_zh":"固体燃料：烟煤、焦炭 分析水分含量 热重法（TGA） 范围 灰分含量 范围 PN-G-04560:1998","technique_zh":"热重法（TGA）","methodology_zh":"分析水分含量","test_object_zh":"固体燃料：烟煤、焦炭"},{"_id":"6a5dc9bbf1c10c8ce825e004","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny, koks","test_object_en":"Solid fuels: hard coal, coke","methodology":"Zawartość chloru","methodology_en":"Chlorine content","parameters":[{"name":"Zakres","range":"(0,005 – 1,00) %"}],"parameters_en":[{"name":"Range","range":"(0,005 – 1,00) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Zawartość chloru\nZakres (0,005 – 1,00) %\nMetoda miareczkowa","reference":"PN-ISO 587:2000 p.7.2.1","norm_bases":["PN-ISO 587:2000 p.7.2.1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny, koks Zawartość chloru\nZakres (0,005 – 1,00) %\nMetoda miareczkowa PN-ISO 587:2000 p.7.2.1 Paliwa stale: wegiel kamienny, koks Zawartosc chloru\nZakres (0,005 – 1,00) %\nMetoda miareczkowa PN-ISO 587:2000 p.7.2.1","categories":["petro"],"row_index":56,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal, coke Chlorine content Titrimetric method Range PN-ISO 587:2000 p.7.2.1","parameters_zh":[{"name":"范围","range":"(0,005 – 1,00) %"}],"search_zh":"固体燃料：烟煤、焦炭 氯含量 滴定法 范围 PN-ISO 587:2000 p.7.2.1","technique_zh":"滴定法","methodology_zh":"氯含量","test_object_zh":"固体燃料：烟煤、焦炭"},{"_id":"6a5dc9bbf1c10c8ce825e005","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny, koks","test_object_en":"Solid fuels: hard coal, coke","methodology":"Zawartość siarki całkowitej","methodology_en":"Total sulfur content","parameters":[{"name":"Zakres","range":"(0,01 – 4,50) %"}],"parameters_en":[{"name":"Range","range":"(0,01 – 4,50) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"technique_en":"High-temperature combustion with IR detection","computed":[],"computed_en":[],"activity":"Zawartość siarki całkowitej\nZakres (0,01 – 4,50) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04584:2001","norm_bases":["PN-G-04584:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny, koks Zawartość siarki całkowitej\nZakres (0,01 – 4,50) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04584:2001 Paliwa stale: wegiel kamienny, koks Zawartosc siarki calkowitej\nZakres (0,01 – 4,50) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04584:2001","categories":["petro"],"row_index":57,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal, coke Total sulfur content High-temperature combustion with IR detection Range PN-G-04584:2001","methodology_zh":"全硫含量","parameters_zh":[{"name":"范围","range":"(0,01 – 4,50) %"}],"search_zh":"固体燃料：烟煤、焦炭 全硫含量 高温燃烧红外检测法 范围 PN-G-04584:2001","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：烟煤、焦炭"},{"_id":"6a5dc9bbf1c10c8ce825e006","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny, koks","test_object_en":"Solid fuels: hard coal, coke","methodology":"Zawartość węgla całkowitego","methodology_en":"Total carbon content","parameters":[{"name":"Zakres","range":"(12,0 – 99,9) %"},{"name":"Zawartość wodoru"},{"name":"Zakres","range":"(0,05 – 6,00) %"}],"parameters_en":[{"name":"Range","range":"(12,0 – 99,9) %"},{"name":"Hydrogen content"},{"name":"Range","range":"(0,05 – 6,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"technique_en":"High-temperature combustion with IR detection","computed":[],"computed_en":[],"activity":"Zawartość węgla całkowitego\nZakres:\nZakres (12,0 – 99,9) %\nZawartość wodoru\nZakres (0,05 – 6,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04571:1998","norm_bases":["PN-G-04571:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny, koks Zawartość węgla całkowitego\nZakres:\nZakres (12,0 – 99,9) %\nZawartość wodoru\nZakres (0,05 – 6,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04571:1998 Paliwa stale: wegiel kamienny, koks Zawartosc wegla calkowitego\nZakres:\nZakres (12,0 – 99,9) %\nZawartosc wodoru\nZakres (0,05 – 6,00) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04571:1998","categories":["petro"],"row_index":58,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal, coke Total carbon content High-temperature combustion with IR detection Range Hydrogen content Range PN-G-04571:1998","methodology_zh":"总碳含量","parameters_zh":[{"name":"范围","range":"(12,0 – 99,9) %"},{"name":"氢含量"},{"name":"范围","range":"(0,05 – 6,00) %"}],"search_zh":"固体燃料：烟煤、焦炭 总碳含量 高温燃烧红外检测法 范围 氢含量 范围 PN-G-04571:1998","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：烟煤、焦炭"},{"_id":"6a5dc9bbf1c10c8ce825e007","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Paliwa stałe: Koks","test_object_en":"Solid fuels: Coke","methodology":"Zawartość wilgoci całkowitej","methodology_en":"Total moisture content","parameters":[{"name":"Zakres","range":"(0,5 – 12,5) %"}],"parameters_en":[{"name":"Range","range":"(0,5 – 12,5) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość wilgoci całkowitej\nZakres (0,5 – 12,5) %\nMetoda wagowa","reference":"PN-ISO 579:2002","norm_bases":["PN-ISO 579:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: Koks Zawartość wilgoci całkowitej\nZakres (0,5 – 12,5) %\nMetoda wagowa PN-ISO 579:2002 Paliwa stale: Koks Zawartosc wilgoci calkowitej\nZakres (0,5 – 12,5) %\nMetoda wagowa PN-ISO 579:2002","categories":["petro"],"row_index":59,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: Coke Total moisture content Gravimetric method Range PN-ISO 579:2002","methodology_zh":"全水分含量","parameters_zh":[{"name":"范围","range":"(0,5 – 12,5) %"}],"search_zh":"全水分含量 重量法 范围 PN-ISO 579:2002","technique_zh":"重量法"},{"_id":"6a5dc9bbf1c10c8ce825e008","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Paliwa stałe: Koks","test_object_en":"Solid fuels: Coke","methodology":"Zawartość wilgoci analitycznej","methodology_en":"Analytical moisture content","parameters":[{"name":"Zakres","range":"(0,10 – 20,0) %"}],"parameters_en":[{"name":"Range","range":"(0,10 – 20,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość wilgoci analitycznej\nZakres (0,10 – 20,0) %\nMetoda wagowa","reference":"PN-ISO 687:2005","norm_bases":["PN-ISO 687:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: Koks Zawartość wilgoci analitycznej\nZakres (0,10 – 20,0) %\nMetoda wagowa PN-ISO 687:2005 Paliwa stale: Koks Zawartosc wilgoci analitycznej\nZakres (0,10 – 20,0) %\nMetoda wagowa PN-ISO 687:2005","categories":["petro"],"row_index":60,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: Coke Analytical moisture content Gravimetric method Range PN-ISO 687:2005","parameters_zh":[{"name":"范围","range":"(0,10 – 20,0) %"}],"search_zh":"分析水分含量 重量法 范围 PN-ISO 687:2005","technique_zh":"重量法","methodology_zh":"分析水分含量"},{"_id":"6a5dc9bbf1c10c8ce825e009","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Paliwa stałe: biopaliwa stałe – biomasa stała","test_object_en":"Solid fuels: solid biofuels – solid biomass","methodology":"Zawartość wilgoci całkowitej","methodology_en":"Total moisture content","parameters":[{"name":"Zakres","range":"(1,0 – 60,0) %"}],"parameters_en":[{"name":"Range","range":"(1,0 – 60,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość wilgoci całkowitej\nZakres (1,0 – 60,0) %\nMetoda wagowa","reference":"PN-EN ISO 18134-1:2023-02","norm_bases":["PN-EN ISO 18134-1:2023-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biopaliwa stałe – biomasa stała Zawartość wilgoci całkowitej\nZakres (1,0 – 60,0) %\nMetoda wagowa PN-EN ISO 18134-1:2023-02 Paliwa stale: biopaliwa stale – biomasa stala Zawartosc wilgoci calkowitej\nZakres (1,0 – 60,0) %\nMetoda wagowa PN-EN ISO 18134-1:2023-02","categories":["petro"],"row_index":61,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: solid biofuels – solid biomass Total moisture content Gravimetric method Range PN-EN ISO 18134-1:2023-02","methodology_zh":"全水分含量","parameters_zh":[{"name":"范围","range":"(1,0 – 60,0) %"}],"search_zh":"固体燃料：固体生物燃料 － 固体生物质 全水分含量 重量法 范围 PN-EN ISO 18134-1:2023-02","technique_zh":"重量法","test_object_zh":"固体燃料：固体生物燃料 － 固体生物质"},{"_id":"6a5dc9bbf1c10c8ce825e00a","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Paliwa stałe: biopaliwa stałe – biomasa stała","test_object_en":"Solid fuels: solid biofuels – solid biomass","methodology":"Zawartość wilgoci w próbce analitycznej","methodology_en":"Moisture content in the analytical sample","parameters":[{"name":"Zakres","range":"(1,5 – 21,0) %"}],"parameters_en":[{"name":"Range","range":"(1,5 – 21,0) %"}],"technique":"Metoda termograwimetryczna (TGA); Metoda wagowa","techniques":["Metoda termograwimetryczna (TGA)","Metoda wagowa"],"technique_en":"Thermogravimetric method (TGA); Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (1,5 – 21,0) %\nMetoda termograwimetryczna (TGA); Metoda wagowa","reference":"PN-EN ISO 18134-3:2023-12","norm_bases":["PN-EN ISO 18134-3:2023-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biopaliwa stałe – biomasa stała Zawartość wilgoci w próbce analitycznej\nZakres (1,5 – 21,0) %\nMetoda termograwimetryczna (TGA); Metoda wagowa PN-EN ISO 18134-3:2023-12 Paliwa stale: biopaliwa stale – biomasa stala Zawartosc wilgoci w probce analitycznej\nZakres (1,5 – 21,0) %\nMetoda termograwimetryczna (TGA); Metoda wagowa PN-EN ISO 18134-3:2023-12","categories":["petro"],"row_index":62,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: solid biofuels – solid biomass Moisture content in the analytical sample Thermogravimetric method (TGA); Gravimetric method Range PN-EN ISO 18134-3:2023-12","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(1,5 – 21,0) %"}],"search_zh":"固体燃料：固体生物燃料 － 固体生物质 分析样品水分含量 热重法（TGA）；重量法 范围 PN-EN ISO 18134-3:2023-12","test_object_zh":"固体燃料：固体生物燃料 － 固体生物质","technique_zh":"热重法（TGA）；重量法"},{"_id":"6a5dc9bbf1c10c8ce825e00b","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Paliwa stałe: biopaliwa stałe – biomasa stała","test_object_en":"Solid fuels: solid biofuels – solid biomass","methodology":"Zawartość popiołu","methodology_en":"Ash content","parameters":[{"name":"Zakres","range":"(0,3 – 22,0) %"}],"parameters_en":[{"name":"Range","range":"(0,3 – 22,0) %"}],"technique":"Metoda termograwimetryczna (TGA); Metoda wagowa","techniques":["Metoda termograwimetryczna (TGA)","Metoda wagowa"],"technique_en":"Thermogravimetric method (TGA); Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość popiołu\nZakres (0,3 – 22,0) %\nMetoda termograwimetryczna (TGA); Metoda wagowa","reference":"PN-EN ISO 18122:2023-05","norm_bases":["PN-EN ISO 18122:2023-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biopaliwa stałe – biomasa stała Zawartość popiołu\nZakres (0,3 – 22,0) %\nMetoda termograwimetryczna (TGA); Metoda wagowa PN-EN ISO 18122:2023-05 Paliwa stale: biopaliwa stale – biomasa stala Zawartosc popiolu\nZakres (0,3 – 22,0) %\nMetoda termograwimetryczna (TGA); Metoda wagowa PN-EN ISO 18122:2023-05","categories":["petro"],"row_index":63,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: solid biofuels – solid biomass Ash content Thermogravimetric method (TGA); Gravimetric method Range PN-EN ISO 18122:2023-05","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(0,3 – 22,0) %"}],"search_zh":"固体燃料：固体生物燃料 － 固体生物质 灰分含量 热重法（TGA）；重量法 范围 PN-EN ISO 18122:2023-05","test_object_zh":"固体燃料：固体生物燃料 － 固体生物质","technique_zh":"热重法（TGA）；重量法"},{"_id":"6a5dc9bbf1c10c8ce825e00c","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Paliwa stałe: biopaliwa stałe – biomasa stała","test_object_en":"Solid fuels: solid biofuels – solid biomass","methodology":"Zawartość części lotnych","methodology_en":"Volatile matter content","parameters":[{"name":"Zakres","range":"(40,0 – 80,0) %"}],"parameters_en":[{"name":"Range","range":"(40,0 – 80,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość części lotnych\nZakres (40,0 – 80,0) %\nMetoda wagowa","reference":"PN-EN ISO 18123:2023-10","norm_bases":["PN-EN ISO 18123:2023-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biopaliwa stałe – biomasa stała Zawartość części lotnych\nZakres (40,0 – 80,0) %\nMetoda wagowa PN-EN ISO 18123:2023-10 Paliwa stale: biopaliwa stale – biomasa stala Zawartosc czesci lotnych\nZakres (40,0 – 80,0) %\nMetoda wagowa PN-EN ISO 18123:2023-10","categories":["petro"],"row_index":64,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: solid biofuels – solid biomass Volatile matter content Gravimetric method Range PN-EN ISO 18123:2023-10","parameters_zh":[{"name":"范围","range":"(40,0 – 80,0) %"}],"search_zh":"固体燃料：固体生物燃料 － 固体生物质 挥发分含量 重量法 范围 PN-EN ISO 18123:2023-10","technique_zh":"重量法","methodology_zh":"挥发分含量","test_object_zh":"固体燃料：固体生物燃料 － 固体生物质"},{"_id":"6a5dc9bbf1c10c8ce825e00d","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Paliwa stałe: biopaliwa stałe – biomasa stała","test_object_en":"Solid fuels: solid biofuels – solid biomass","methodology":"Ciepło spalania","methodology_en":"Gross calorific value","parameters":[{"name":"Zakres","range":"(10 000 – 25 000) kJ/kg"},{"name":"Wartość opałowa (z obliczeń)"}],"parameters_en":[{"name":"Range","range":"(10 000 – 25 000) kJ/kg"},{"name":"Net calorific value (calculated)"}],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna"],"technique_en":"Calorimetric method","computed":[],"computed_en":[],"activity":"Ciepło spalania\nZakres:\nZakres (10 000 – 25 000) kJ/kg\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna","reference":"PN-EN ISO 18125:2017-07","norm_bases":["PN-EN ISO 18125:2017-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biopaliwa stałe – biomasa stała Ciepło spalania\nZakres:\nZakres (10 000 – 25 000) kJ/kg\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna PN-EN ISO 18125:2017-07 Paliwa stale: biopaliwa stale – biomasa stala Cieplo spalania\nZakres:\nZakres (10 000 – 25 000) kJ/kg\nWartosc opalowa (z obliczen)\nMetoda kalorymetryczna PN-EN ISO 18125:2017-07","categories":["petro"],"row_index":65,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: solid biofuels – solid biomass Gross calorific value Calorimetric method Range Net calorific value (calculated) PN-EN ISO 18125:2017-07","methodology_zh":"高位发热量","parameters_zh":[{"name":"范围","range":"(10 000 – 25 000) kJ/kg"},{"name":"低位发热量（计算值）"}],"search_zh":"固体燃料：固体生物燃料 － 固体生物质 高位发热量 量热法 范围 低位发热量（计算值） PN-EN ISO 18125:2017-07","technique_zh":"量热法","test_object_zh":"固体燃料：固体生物燃料 － 固体生物质"},{"_id":"6a5dc9bbf1c10c8ce825e00e","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Paliwa stałe: biopaliwa stałe – biomasa stała","test_object_en":"Solid fuels: solid biofuels – solid biomass","methodology":"Zawartość węgla całkowitego","methodology_en":"Total carbon content","parameters":[{"name":"Zakres","range":"(35,0 – 75,0) %"},{"name":"Zawartość wodoru"},{"name":"Zakres","range":"(2,50 – 6,50) %"}],"parameters_en":[{"name":"Range","range":"(35,0 – 75,0) %"},{"name":"Hydrogen content"},{"name":"Range","range":"(2,50 – 6,50) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"technique_en":"High-temperature combustion with IR detection","computed":[],"computed_en":[],"activity":"Zawartość węgla całkowitego\nZakres:\nZakres (35,0 – 75,0) %\nZawartość wodoru\nZakres (2,50 – 6,50) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN ISO 16948:2015-07","norm_bases":["PN-EN ISO 16948:2015-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biopaliwa stałe – biomasa stała Zawartość węgla całkowitego\nZakres:\nZakres (35,0 – 75,0) %\nZawartość wodoru\nZakres (2,50 – 6,50) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN ISO 16948:2015-07 Paliwa stale: biopaliwa stale – biomasa stala Zawartosc wegla calkowitego\nZakres:\nZakres (35,0 – 75,0) %\nZawartosc wodoru\nZakres (2,50 – 6,50) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN ISO 16948:2015-07","categories":["petro"],"row_index":66,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: solid biofuels – solid biomass Total carbon content High-temperature combustion with IR detection Range Hydrogen content Range PN-EN ISO 16948:2015-07","methodology_zh":"总碳含量","parameters_zh":[{"name":"范围","range":"(35,0 – 75,0) %"},{"name":"氢含量"},{"name":"范围","range":"(2,50 – 6,50) %"}],"search_zh":"固体燃料：固体生物燃料 － 固体生物质 总碳含量 高温燃烧红外检测法 范围 氢含量 范围 PN-EN ISO 16948:2015-07","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：固体生物燃料 － 固体生物质"},{"_id":"6a5dc9bbf1c10c8ce825e00f","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Paliwa stałe: biopaliwa stałe – biomasa stała","test_object_en":"Solid fuels: solid biofuels – solid biomass","methodology":"Zawartość siarki","methodology_en":"Sulfur content","parameters":[{"name":"Zakres","range":"(0,01 – 1,00) %"}],"parameters_en":[{"name":"Range","range":"(0,01 – 1,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"technique_en":"High-temperature combustion with IR detection","computed":[],"computed_en":[],"activity":"Zawartość siarki\nZakres (0,01 – 1,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN ISO 16994:2016-10","norm_bases":["PN-EN ISO 16994:2016-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biopaliwa stałe – biomasa stała Zawartość siarki\nZakres (0,01 – 1,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN ISO 16994:2016-10 Paliwa stale: biopaliwa stale – biomasa stala Zawartosc siarki\nZakres (0,01 – 1,00) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN ISO 16994:2016-10","categories":["petro"],"row_index":67,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: solid biofuels – solid biomass Sulfur content High-temperature combustion with IR detection Range PN-EN ISO 16994:2016-10","parameters_zh":[{"name":"范围","range":"(0,01 – 1,00) %"}],"search_zh":"固体燃料：固体生物燃料 － 固体生物质 硫含量 高温燃烧红外检测法 范围 PN-EN ISO 16994:2016-10","technique_zh":"高温燃烧红外检测法","methodology_zh":"硫含量","test_object_zh":"固体燃料：固体生物燃料 － 固体生物质"},{"_id":"6a5dc9bbf1c10c8ce825e010","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Paliwa stałe: biopaliwa stałe – biomasa stała","test_object_en":"Solid fuels: solid biofuels – solid biomass","methodology":"Zawartość frakcji biodegradowalnej – udział masowy biomasy z zastosowaniem selektywnego","methodology_en":"Biodegradable fraction content – biomass mass fraction using selective","parameters":[{"name":"rozpuszczania"},{"name":"Zakres","range":"(20,0 - 99,9) %"},{"name":"Zawartość frakcji niebiodegradowalnej – udział masowy niebiomasy (z obliczeń) Zawartość frakcji biodegradowalnej – udział biomasy na podstawie węgla całkowitego (z obliczeń)"}],"parameters_en":[{"name":"dissolution"},{"name":"Range","range":"(20,0 - 99,9) %"},{"name":"Content of the non-biodegradable fraction – mass fraction of non-biomass (calculated) Content of the biodegradable fraction – biomass fraction based on total carbon (calculated)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość frakcji biodegradowalnej – udział masowy biomasy z zastosowaniem selektywnego\nZakres:\nrozpuszczania\nZakres (20,0 - 99,9) %\nZawartość frakcji niebiodegradowalnej – udział masowy niebiomasy (z obliczeń) Zawartość frakcji biodegradowalnej – udział biomasy na podstawie węgla całkowitego (z obliczeń)\nMetoda wagowa","reference":"PN-EN ISO 21644:2021-07 Aneks B, p. B.7 i B.9","norm_bases":["PN-EN ISO 21644:2021-07 Aneks B, p. B.7 i B.9"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biopaliwa stałe – biomasa stała Zawartość frakcji biodegradowalnej – udział masowy biomasy z zastosowaniem selektywnego\nZakres:\nrozpuszczania\nZakres (20,0 - 99,9) %\nZawartość frakcji niebiodegradowalnej – udział masowy niebiomasy (z obliczeń) Zawartość frakcji biodegradowalnej – udział biomasy na podstawie węgla całkowitego (z obliczeń)\nMetoda wagowa PN-EN ISO 21644:2021-07 Aneks B, p. B.7 i B.9 Paliwa stale: biopaliwa stale – biomasa stala Zawartosc frakcji biodegradowalnej – udzial masowy biomasy z zastosowaniem selektywnego\nZakres:\nrozpuszczania\nZakres (20,0 - 99,9) %\nZawartosc frakcji niebiodegradowalnej – udzial masowy niebiomasy (z obliczen) Zawartosc frakcji biodegradowalnej – udzial biomasy na podstawie wegla calkowitego (z obliczen)\nMetoda wagowa PN-EN ISO 21644:2021-07 Aneks B, p. B.7 i B.9","categories":["petro"],"row_index":68,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: solid biofuels – solid biomass Biodegradable fraction content – biomass mass fraction using selective Gravimetric method dissolution Range Content of the non-biodegradable fraction – mass fraction of non-biomass (calculated) Content of the biodegradable fraction – biomass fraction based on total carbon (calculated) PN-EN ISO 21644:2021-07 Aneks B, p. B.7 i B.9","parameters_zh":[{"name":"溶解"},{"name":"范围","range":"(20,0 - 99,9) %"},{"name":"Zawartość frakcji niebiodegradowalnej – udział masowy niebiomasy (z obliczeń) Zawartość frakcji biodegradowalnej – udział biomasy na podstawie węgla całkowitego (z obliczeń)"}],"search_zh":"固体燃料：固体生物燃料 － 固体生物质 可生物降解组分含量 － 采用选择性溶解法测定的生物质质量分数 重量法 溶解 范围 PN-EN ISO 21644:2021-07 Aneks B, p. B.7 i B.9","technique_zh":"重量法","test_object_zh":"固体燃料：固体生物燃料 － 固体生物质","methodology_zh":"可生物降解组分含量 － 采用选择性溶解法测定的生物质质量分数"},{"_id":"6a5dc9bbf1c10c8ce825e011","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Paliwa stałe: biopaliwa stałe – biomasa stała","test_object_en":"Solid fuels: solid biofuels – solid biomass","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-EN ISO 18135:2017-06 p. 12.2.3.3","norm_bases":["PN-EN ISO 18135:2017-06 p. 12.2.3.3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biopaliwa stałe – biomasa stała Pobieranie próbek do badań chemicznych i fizycznych PN-EN ISO 18135:2017-06 p. 12.2.3.3 Paliwa stale: biopaliwa stale – biomasa stala Pobieranie probek do badan chemicznych i fizycznych PN-EN ISO 18135:2017-06 p. 12.2.3.3","categories":["petro"],"row_index":69,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: solid biofuels – solid biomass Sampling for chemical and physical testing PN-EN ISO 18135:2017-06 p. 12.2.3.3","methodology_zh":"化学与物理检测用样品采集","search_zh":"固体燃料：固体生物燃料 － 固体生物质 化学与物理检测用样品采集 PN-EN ISO 18135:2017-06 p. 12.2.3.3","test_object_zh":"固体燃料：固体生物燃料 － 固体生物质"},{"_id":"6a5dc9bbf1c10c8ce825e012","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwa wtórne, Odpady: kod 03 03 05, 03 03 07, 03 03 10, 19 12 10, 19 12 12, 20 03 01, 19 12 11*","test_object_en":"Solid fuels: solid recovered fuels, Waste: code 03 03 05, 03 03 07, 03 03 10, 19 12 10, 19 12 12, 20 03 01, 19 12 11*","methodology":"Ciepło spalania","methodology_en":"Gross calorific value","parameters":[{"name":"Zakres","range":"(4 000 – 36 000) kJ/kg"},{"name":"Wartość opałowa (z obliczeń)"}],"parameters_en":[{"name":"Range","range":"(4 000 – 36 000) kJ/kg"},{"name":"Net calorific value (calculated)"}],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna"],"technique_en":"Calorimetric method","computed":[],"computed_en":[],"activity":"Ciepło spalania\nZakres:\nZakres (4 000 – 36 000) kJ/kg\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna","reference":"PN-EN ISO 21654:2021-12","norm_bases":["PN-EN ISO 21654:2021-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: stałe paliwa wtórne, Odpady: kod 03 03 05, 03 03 07, 03 03 10, 19 12 10, 19 12 12, 20 03 01, 19 12 11* Ciepło spalania\nZakres:\nZakres (4 000 – 36 000) kJ/kg\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna PN-EN ISO 21654:2021-12 Paliwa stale: stale paliwa wtorne, Odpady: kod 03 03 05, 03 03 07, 03 03 10, 19 12 10, 19 12 12, 20 03 01, 19 12 11* Cieplo spalania\nZakres:\nZakres (4 000 – 36 000) kJ/kg\nWartosc opalowa (z obliczen)\nMetoda kalorymetryczna PN-EN ISO 21654:2021-12","categories":["environment","petro"],"row_index":70,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: solid recovered fuels, Waste: code 03 03 05, 03 03 07, 03 03 10, 19 12 10, 19 12 12, 20 03 01, 19 12 11* Gross calorific value Calorimetric method Range Net calorific value (calculated) PN-EN ISO 21654:2021-12","methodology_zh":"高位发热量","parameters_zh":[{"name":"范围","range":"(4 000 – 36 000) kJ/kg"},{"name":"低位发热量（计算值）"}],"search_zh":"固体燃料：固体再生燃料；废物：代码 03 03 05、03 03 07、03 03 10、19 12 10、19 12 12、20 03 01、19 12 11* 高位发热量 量热法 范围 低位发热量（计算值） PN-EN ISO 21654:2021-12","technique_zh":"量热法","test_object_zh":"固体燃料：固体再生燃料；废物：代码 03 03 05、03 03 07、03 03 10、19 12 10、19 12 12、20 03 01、19 12 11*"},{"_id":"6a5dc9bbf1c10c8ce825e013","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwa wtórne, Odpady: kod 03 03 05, 03 03 07, 03 03 10, 19 12 10, 19 12 12, 20 03 01, 19 12 11*","test_object_en":"Solid fuels: solid recovered fuels, Waste: code 03 03 05, 03 03 07, 03 03 10, 19 12 10, 19 12 12, 20 03 01, 19 12 11*","methodology":"Zawartość wilgoci całkowitej","methodology_en":"Total moisture content","parameters":[{"name":"Zakres","range":"(0,1 – 90,0) %"}],"parameters_en":[{"name":"Range","range":"(0,1 – 90,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość wilgoci całkowitej\nZakres (0,1 – 90,0) %\nMetoda wagowa","reference":"CEN/TS 15414-1:2010","norm_bases":["CEN/TS 15414-1:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: stałe paliwa wtórne, Odpady: kod 03 03 05, 03 03 07, 03 03 10, 19 12 10, 19 12 12, 20 03 01, 19 12 11* Zawartość wilgoci całkowitej\nZakres (0,1 – 90,0) %\nMetoda wagowa CEN/TS 15414-1:2010 Paliwa stale: stale paliwa wtorne, Odpady: kod 03 03 05, 03 03 07, 03 03 10, 19 12 10, 19 12 12, 20 03 01, 19 12 11* Zawartosc wilgoci calkowitej\nZakres (0,1 – 90,0) %\nMetoda wagowa CEN/TS 15414-1:2010","categories":["environment","petro"],"row_index":71,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: solid recovered fuels, Waste: code 03 03 05, 03 03 07, 03 03 10, 19 12 10, 19 12 12, 20 03 01, 19 12 11* Total moisture content Gravimetric method Range CEN/TS 15414-1:2010","methodology_zh":"全水分含量","parameters_zh":[{"name":"范围","range":"(0,1 – 90,0) %"}],"search_zh":"固体燃料：固体再生燃料；废物：代码 03 03 05、03 03 07、03 03 10、19 12 10、19 12 12、20 03 01、19 12 11* 全水分含量 重量法 范围 CEN/TS 15414-1:2010","technique_zh":"重量法","test_object_zh":"固体燃料：固体再生燃料；废物：代码 03 03 05、03 03 07、03 03 10、19 12 10、19 12 12、20 03 01、19 12 11*"},{"_id":"6a5dc9bbf1c10c8ce825e014","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwa wtórne, Odpady: kod 03 03 05, 03 03 07, 03 03 10, 19 12 10, 19 12 12, 20 03 01, 19 12 11*","test_object_en":"Solid fuels: solid recovered fuels, Waste: code 03 03 05, 03 03 07, 03 03 10, 19 12 10, 19 12 12, 20 03 01, 19 12 11*","methodology":"Zawartość wilgoci w próbce analitycznej","methodology_en":"Moisture content in the analytical sample","parameters":[{"name":"Zakres","range":"(0,10 – 15,0) %"}],"parameters_en":[{"name":"Range","range":"(0,10 – 15,0) %"}],"technique":"Metoda termograwimetryczna (TGA); Metoda wagowa","techniques":["Metoda termograwimetryczna (TGA)","Metoda wagowa"],"technique_en":"Thermogravimetric method (TGA); Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (0,10 – 15,0) %\nMetoda termograwimetryczna (TGA); Metoda wagowa","reference":"PN-EN ISO 21660-3:2021-08","norm_bases":["PN-EN ISO 21660-3:2021-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: stałe paliwa wtórne, Odpady: kod 03 03 05, 03 03 07, 03 03 10, 19 12 10, 19 12 12, 20 03 01, 19 12 11* Zawartość wilgoci w próbce analitycznej\nZakres (0,10 – 15,0) %\nMetoda termograwimetryczna (TGA); Metoda wagowa PN-EN ISO 21660-3:2021-08 Paliwa stale: stale paliwa wtorne, Odpady: kod 03 03 05, 03 03 07, 03 03 10, 19 12 10, 19 12 12, 20 03 01, 19 12 11* Zawartosc wilgoci w probce analitycznej\nZakres (0,10 – 15,0) %\nMetoda termograwimetryczna (TGA); Metoda wagowa PN-EN ISO 21660-3:2021-08","categories":["environment","petro"],"row_index":72,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: solid recovered fuels, Waste: code 03 03 05, 03 03 07, 03 03 10, 19 12 10, 19 12 12, 20 03 01, 19 12 11* Moisture content in the analytical sample Thermogravimetric method (TGA); Gravimetric method Range PN-EN ISO 21660-3:2021-08","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(0,10 – 15,0) %"}],"search_zh":"固体燃料：固体再生燃料；废物：代码 03 03 05、03 03 07、03 03 10、19 12 10、19 12 12、20 03 01、19 12 11* 分析样品水分含量 热重法（TGA）；重量法 范围 PN-EN ISO 21660-3:2021-08","test_object_zh":"固体燃料：固体再生燃料；废物：代码 03 03 05、03 03 07、03 03 10、19 12 10、19 12 12、20 03 01、19 12 11*","technique_zh":"热重法（TGA）；重量法"},{"_id":"6a5dc9bbf1c10c8ce825e015","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwa wtórne, Odpady: kod 03 03 05, 03 03 07, 03 03 10, 19 12 10, 19 12 12, 20 03 01, 19 12 11*","test_object_en":"Solid fuels: solid recovered fuels, Waste: code 03 03 05, 03 03 07, 03 03 10, 19 12 10, 19 12 12, 20 03 01, 19 12 11*","methodology":"Zawartość popiołu","methodology_en":"Ash content","parameters":[{"name":"Zakres","range":"(0,8 – 73,0) %"}],"parameters_en":[{"name":"Range","range":"(0,8 – 73,0) %"}],"technique":"Metoda termograwimetryczna (TGA); Metoda wagowa","techniques":["Metoda termograwimetryczna (TGA)","Metoda wagowa"],"technique_en":"Thermogravimetric method (TGA); Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość popiołu\nZakres (0,8 – 73,0) %\nMetoda termograwimetryczna (TGA); Metoda wagowa","reference":"PN-EN ISO 21656:2021-08","norm_bases":["PN-EN ISO 21656:2021-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: stałe paliwa wtórne, Odpady: kod 03 03 05, 03 03 07, 03 03 10, 19 12 10, 19 12 12, 20 03 01, 19 12 11* Zawartość popiołu\nZakres (0,8 – 73,0) %\nMetoda termograwimetryczna (TGA); Metoda wagowa PN-EN ISO 21656:2021-08 Paliwa stale: stale paliwa wtorne, Odpady: kod 03 03 05, 03 03 07, 03 03 10, 19 12 10, 19 12 12, 20 03 01, 19 12 11* Zawartosc popiolu\nZakres (0,8 – 73,0) %\nMetoda termograwimetryczna (TGA); Metoda wagowa PN-EN ISO 21656:2021-08","categories":["environment","petro"],"row_index":73,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: solid recovered fuels, Waste: code 03 03 05, 03 03 07, 03 03 10, 19 12 10, 19 12 12, 20 03 01, 19 12 11* Ash content Thermogravimetric method (TGA); Gravimetric method Range PN-EN ISO 21656:2021-08","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(0,8 – 73,0) %"}],"search_zh":"固体燃料：固体再生燃料；废物：代码 03 03 05、03 03 07、03 03 10、19 12 10、19 12 12、20 03 01、19 12 11* 灰分含量 热重法（TGA）；重量法 范围 PN-EN ISO 21656:2021-08","test_object_zh":"固体燃料：固体再生燃料；废物：代码 03 03 05、03 03 07、03 03 10、19 12 10、19 12 12、20 03 01、19 12 11*","technique_zh":"热重法（TGA）；重量法"},{"_id":"6a5dc9bbf1c10c8ce825e016","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwa wtórne, Odpady: kod 03 03 05, 03 03 07, 03 03 10, 19 12 10, 19 12 12, 20 03 01, 19 12 11*","test_object_en":"Solid fuels: solid recovered fuels, Waste: code 03 03 05, 03 03 07, 03 03 10, 19 12 10, 19 12 12, 20 03 01, 19 12 11*","methodology":"Zawartość części lotnych","methodology_en":"Volatile matter content","parameters":[{"name":"Zakres","range":"(10,0 – 80,0) %"}],"parameters_en":[{"name":"Range","range":"(10,0 – 80,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość części lotnych\nZakres (10,0 – 80,0) %\nMetoda wagowa","reference":"PN-EN ISO 22167:2021-08","norm_bases":["PN-EN ISO 22167:2021-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: stałe paliwa wtórne, Odpady: kod 03 03 05, 03 03 07, 03 03 10, 19 12 10, 19 12 12, 20 03 01, 19 12 11* Zawartość części lotnych\nZakres (10,0 – 80,0) %\nMetoda wagowa PN-EN ISO 22167:2021-08 Paliwa stale: stale paliwa wtorne, Odpady: kod 03 03 05, 03 03 07, 03 03 10, 19 12 10, 19 12 12, 20 03 01, 19 12 11* Zawartosc czesci lotnych\nZakres (10,0 – 80,0) %\nMetoda wagowa PN-EN ISO 22167:2021-08","categories":["environment","petro"],"row_index":74,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: solid recovered fuels, Waste: code 03 03 05, 03 03 07, 03 03 10, 19 12 10, 19 12 12, 20 03 01, 19 12 11* Volatile matter content Gravimetric method Range PN-EN ISO 22167:2021-08","parameters_zh":[{"name":"范围","range":"(10,0 – 80,0) %"}],"search_zh":"固体燃料：固体再生燃料；废物：代码 03 03 05、03 03 07、03 03 10、19 12 10、19 12 12、20 03 01、19 12 11* 挥发分含量 重量法 范围 PN-EN ISO 22167:2021-08","technique_zh":"重量法","methodology_zh":"挥发分含量","test_object_zh":"固体燃料：固体再生燃料；废物：代码 03 03 05、03 03 07、03 03 10、19 12 10、19 12 12、20 03 01、19 12 11*"},{"_id":"6a5dc9bbf1c10c8ce825e017","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwa wtórne, Odpady: kod 03 03 05, 03 03 07, 03 03 10, 19 12 10, 19 12 12, 20 03 01, 19 12 11*","test_object_en":"Solid fuels: solid recovered fuels, Waste: code 03 03 05, 03 03 07, 03 03 10, 19 12 10, 19 12 12, 20 03 01, 19 12 11*","methodology":"Zawartość węgla całkowitego","methodology_en":"Total carbon content","parameters":[{"name":"Zakres","range":"(10,0 – 75,0) %"},{"name":"Zawartość wodoru"},{"name":"Zakres","range":"(1,50 – 10,0) %"}],"parameters_en":[{"name":"Range","range":"(10,0 – 75,0) %"},{"name":"Hydrogen content"},{"name":"Range","range":"(1,50 – 10,0) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"technique_en":"High-temperature combustion with IR detection","computed":[],"computed_en":[],"activity":"Zawartość węgla całkowitego\nZakres:\nZakres (10,0 – 75,0) %\nZawartość wodoru\nZakres (1,50 – 10,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN ISO 21663:2021-06","norm_bases":["PN-EN ISO 21663:2021-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: stałe paliwa wtórne, Odpady: kod 03 03 05, 03 03 07, 03 03 10, 19 12 10, 19 12 12, 20 03 01, 19 12 11* Zawartość węgla całkowitego\nZakres:\nZakres (10,0 – 75,0) %\nZawartość wodoru\nZakres (1,50 – 10,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN ISO 21663:2021-06 Paliwa stale: stale paliwa wtorne, Odpady: kod 03 03 05, 03 03 07, 03 03 10, 19 12 10, 19 12 12, 20 03 01, 19 12 11* Zawartosc wegla calkowitego\nZakres:\nZakres (10,0 – 75,0) %\nZawartosc wodoru\nZakres (1,50 – 10,0) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN ISO 21663:2021-06","categories":["environment","petro"],"row_index":75,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: solid recovered fuels, Waste: code 03 03 05, 03 03 07, 03 03 10, 19 12 10, 19 12 12, 20 03 01, 19 12 11* Total carbon content High-temperature combustion with IR detection Range Hydrogen content Range PN-EN ISO 21663:2021-06","methodology_zh":"总碳含量","parameters_zh":[{"name":"范围","range":"(10,0 – 75,0) %"},{"name":"氢含量"},{"name":"范围","range":"(1,50 – 10,0) %"}],"search_zh":"固体燃料：固体再生燃料；废物：代码 03 03 05、03 03 07、03 03 10、19 12 10、19 12 12、20 03 01、19 12 11* 总碳含量 高温燃烧红外检测法 范围 氢含量 范围 PN-EN ISO 21663:2021-06","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：固体再生燃料；废物：代码 03 03 05、03 03 07、03 03 10、19 12 10、19 12 12、20 03 01、19 12 11*"},{"_id":"6a5dc9bbf1c10c8ce825e018","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwa wtórne, Odpady: kod 03 03 05, 03 03 07, 03 03 10, 19 12 10, 19 12 12, 20 03 01, 19 12 11*","test_object_en":"Solid fuels: solid recovered fuels, Waste: code 03 03 05, 03 03 07, 03 03 10, 19 12 10, 19 12 12, 20 03 01, 19 12 11*","methodology":"Zawartość siarki","methodology_en":"Sulfur content","parameters":[{"name":"Zakres","range":"(0,05 – 2,00) %"}],"parameters_en":[{"name":"Range","range":"(0,05 – 2,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"technique_en":"High-temperature combustion with IR detection","computed":[],"computed_en":[],"activity":"Zawartość siarki\nZakres (0,05 – 2,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN ISO 21663:2021-06","norm_bases":["PN-EN ISO 21663:2021-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: stałe paliwa wtórne, Odpady: kod 03 03 05, 03 03 07, 03 03 10, 19 12 10, 19 12 12, 20 03 01, 19 12 11* Zawartość siarki\nZakres (0,05 – 2,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN ISO 21663:2021-06 Paliwa stale: stale paliwa wtorne, Odpady: kod 03 03 05, 03 03 07, 03 03 10, 19 12 10, 19 12 12, 20 03 01, 19 12 11* Zawartosc siarki\nZakres (0,05 – 2,00) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN ISO 21663:2021-06","categories":["environment","petro"],"row_index":76,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: solid recovered fuels, Waste: code 03 03 05, 03 03 07, 03 03 10, 19 12 10, 19 12 12, 20 03 01, 19 12 11* Sulfur content High-temperature combustion with IR detection Range PN-EN ISO 21663:2021-06","parameters_zh":[{"name":"范围","range":"(0,05 – 2,00) %"}],"search_zh":"固体燃料：固体再生燃料；废物：代码 03 03 05、03 03 07、03 03 10、19 12 10、19 12 12、20 03 01、19 12 11* 硫含量 高温燃烧红外检测法 范围 PN-EN ISO 21663:2021-06","technique_zh":"高温燃烧红外检测法","methodology_zh":"硫含量","test_object_zh":"固体燃料：固体再生燃料；废物：代码 03 03 05、03 03 07、03 03 10、19 12 10、19 12 12、20 03 01、19 12 11*"},{"_id":"6a5dc9bbf1c10c8ce825e019","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwa wtórne, Odpady: kod 03 03 05, 03 03 07, 03 03 10, 19 12 10, 19 12 12, 20 03 01, 19 12 11*","test_object_en":"Solid fuels: solid recovered fuels, Waste: code 03 03 05, 03 03 07, 03 03 10, 19 12 10, 19 12 12, 20 03 01, 19 12 11*","methodology":"Zawartość chloru","methodology_en":"Chlorine content","parameters":[{"name":"Zakres","range":"(0,015 – 2,00) %"}],"parameters_en":[{"name":"Range","range":"(0,015 – 2,00) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Zawartość chloru\nZakres (0,015 – 2,00) %\nMetoda miareczkowa","reference":"PN-EN 15408:2011","norm_bases":["PN-EN 15408:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: stałe paliwa wtórne, Odpady: kod 03 03 05, 03 03 07, 03 03 10, 19 12 10, 19 12 12, 20 03 01, 19 12 11* Zawartość chloru\nZakres (0,015 – 2,00) %\nMetoda miareczkowa PN-EN 15408:2011 Paliwa stale: stale paliwa wtorne, Odpady: kod 03 03 05, 03 03 07, 03 03 10, 19 12 10, 19 12 12, 20 03 01, 19 12 11* Zawartosc chloru\nZakres (0,015 – 2,00) %\nMetoda miareczkowa PN-EN 15408:2011","categories":["environment","petro"],"row_index":77,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: solid recovered fuels, Waste: code 03 03 05, 03 03 07, 03 03 10, 19 12 10, 19 12 12, 20 03 01, 19 12 11* Chlorine content Titrimetric method Range PN-EN 15408:2011","parameters_zh":[{"name":"范围","range":"(0,015 – 2,00) %"}],"search_zh":"固体燃料：固体再生燃料；废物：代码 03 03 05、03 03 07、03 03 10、19 12 10、19 12 12、20 03 01、19 12 11* 氯含量 滴定法 范围 PN-EN 15408:2011","technique_zh":"滴定法","methodology_zh":"氯含量","test_object_zh":"固体燃料：固体再生燃料；废物：代码 03 03 05、03 03 07、03 03 10、19 12 10、19 12 12、20 03 01、19 12 11*"},{"_id":"6a5dc9bbf1c10c8ce825e01a","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwa wtórne, Odpady: kod 03 03 05, 03 03 07, 03 03 10, 19 12 10, 19 12 12, 20 03 01","test_object_en":"Solid fuels: solid recovered fuels, Waste: code 03 03 05, 03 03 07, 03 03 10, 19 12 10, 19 12 12, 20 03 01","methodology":"Zawartość frakcji biodegradowalnej – udział masowy biomasy z zastosowaniem selektywnego","methodology_en":"Biodegradable fraction content – biomass mass fraction using selective","parameters":[{"name":"rozpuszczania"},{"name":"Zakres","range":"(20,0 – 99,9) %"},{"name":"Zawartość frakcji niebiodegradowalnej – udział masowy niebiomasy (z obliczeń) Zawartość frakcji biodegradowalnej – udział biomasy na podstawie węgla całkowitego (z obliczeń)"}],"parameters_en":[{"name":"dissolution"},{"name":"Range","range":"(20,0 – 99,9) %"},{"name":"Content of the non-biodegradable fraction – mass fraction of non-biomass (calculated) Content of the biodegradable fraction – biomass fraction based on total carbon (calculated)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość frakcji biodegradowalnej – udział masowy biomasy z zastosowaniem selektywnego\nZakres:\nrozpuszczania\nZakres (20,0 – 99,9) %\nZawartość frakcji niebiodegradowalnej – udział masowy niebiomasy (z obliczeń) Zawartość frakcji biodegradowalnej – udział biomasy na podstawie węgla całkowitego (z obliczeń)\nMetoda wagowa","reference":"PN-EN ISO 21644:2021-07 Aneks B, p. B.7 i B.9","norm_bases":["PN-EN ISO 21644:2021-07 Aneks B, p. B.7 i B.9"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: stałe paliwa wtórne, Odpady: kod 03 03 05, 03 03 07, 03 03 10, 19 12 10, 19 12 12, 20 03 01 Zawartość frakcji biodegradowalnej – udział masowy biomasy z zastosowaniem selektywnego\nZakres:\nrozpuszczania\nZakres (20,0 – 99,9) %\nZawartość frakcji niebiodegradowalnej – udział masowy niebiomasy (z obliczeń) Zawartość frakcji biodegradowalnej – udział biomasy na podstawie węgla całkowitego (z obliczeń)\nMetoda wagowa PN-EN ISO 21644:2021-07 Aneks B, p. B.7 i B.9 Paliwa stale: stale paliwa wtorne, Odpady: kod 03 03 05, 03 03 07, 03 03 10, 19 12 10, 19 12 12, 20 03 01 Zawartosc frakcji biodegradowalnej – udzial masowy biomasy z zastosowaniem selektywnego\nZakres:\nrozpuszczania\nZakres (20,0 – 99,9) %\nZawartosc frakcji niebiodegradowalnej – udzial masowy niebiomasy (z obliczen) Zawartosc frakcji biodegradowalnej – udzial biomasy na podstawie wegla calkowitego (z obliczen)\nMetoda wagowa PN-EN ISO 21644:2021-07 Aneks B, p. B.7 i B.9","categories":["environment","petro"],"row_index":78,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: solid recovered fuels, Waste: code 03 03 05, 03 03 07, 03 03 10, 19 12 10, 19 12 12, 20 03 01 Biodegradable fraction content – biomass mass fraction using selective Gravimetric method dissolution Range Content of the non-biodegradable fraction – mass fraction of non-biomass (calculated) Content of the biodegradable fraction – biomass fraction based on total carbon (calculated) PN-EN ISO 21644:2021-07 Aneks B, p. B.7 i B.9","parameters_zh":[{"name":"溶解"},{"name":"范围","range":"(20,0 – 99,9) %"},{"name":"Zawartość frakcji niebiodegradowalnej – udział masowy niebiomasy (z obliczeń) Zawartość frakcji biodegradowalnej – udział biomasy na podstawie węgla całkowitego (z obliczeń)"}],"search_zh":"可生物降解组分含量 － 采用选择性溶解法测定的生物质质量分数 重量法 溶解 范围 PN-EN ISO 21644:2021-07 Aneks B, p. B.7 i B.9","technique_zh":"重量法","methodology_zh":"可生物降解组分含量 － 采用选择性溶解法测定的生物质质量分数"},{"_id":"6a5dc9bbf1c10c8ce825e01b","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwa wtórne, Odpady: kod 19 12 10, 19 12 12","test_object_en":"Solid fuels: solid recovered fuels, Waste: code 19 12 10, 19 12 12","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-EN ISO 21645:2021-09","norm_bases":["PN-EN ISO 21645:2021-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: stałe paliwa wtórne, Odpady: kod 19 12 10, 19 12 12 Pobieranie próbek do badań chemicznych i fizycznych PN-EN ISO 21645:2021-09 Paliwa stale: stale paliwa wtorne, Odpady: kod 19 12 10, 19 12 12 Pobieranie probek do badan chemicznych i fizycznych PN-EN ISO 21645:2021-09","categories":["environment","petro"],"row_index":79,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: solid recovered fuels, Waste: code 19 12 10, 19 12 12 Sampling for chemical and physical testing PN-EN ISO 21645:2021-09","methodology_zh":"化学与物理检测用样品采集","search_zh":"化学与物理检测用样品采集 PN-EN ISO 21645:2021-09"},{"_id":"6a5dc9bbf1c10c8ce825e01c","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Odpady: kod 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 15, 10 01 17, 10 01 19, 10 01 21, 10 01 23, 10 01 24, 10 01 25, 10 01 80, 10 01 81, 10 01 82, 10 01 99, Odpady paleniskowe: popiół, żużel, mieszanki popiołowo- żużlowe","test_object_en":"Waste: code 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 15, 10 01 17, 10 01 19, 10 01 21, 10 01 23, 10 01 24, 10 01 25, 10 01 80, 10 01 81, 10 01 82, 10 01 99, Combustion waste: ash, slag, ash-slag mixtures","methodology":"Zawartość węgla całkowitego","methodology_en":"Total carbon content","parameters":[{"name":"Zakres","range":"(0,5 – 30,0) %"}],"parameters_en":[{"name":"Range","range":"(0,5 – 30,0) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"technique_en":"High-temperature combustion with IR detection","computed":[],"computed_en":[],"activity":"Zawartość węgla całkowitego\nZakres (0,5 – 30,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04571:1998","norm_bases":["PN-G-04571:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady: kod 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 15, 10 01 17, 10 01 19, 10 01 21, 10 01 23, 10 01 24, 10 01 25, 10 01 80, 10 01 81, 10 01 82, 10 01 99, Odpady paleniskowe: popiół, żużel, mieszanki popiołowo- żużlowe Zawartość węgla całkowitego\nZakres (0,5 – 30,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04571:1998 Odpady: kod 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 15, 10 01 17, 10 01 19, 10 01 21, 10 01 23, 10 01 24, 10 01 25, 10 01 80, 10 01 81, 10 01 82, 10 01 99, Odpady paleniskowe: popiol, zuzel, mieszanki popiolowo- zuzlowe Zawartosc wegla calkowitego\nZakres (0,5 – 30,0) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04571:1998","categories":["environment"],"row_index":80,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste: code 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 15, 10 01 17, 10 01 19, 10 01 21, 10 01 23, 10 01 24, 10 01 25, 10 01 80, 10 01 81, 10 01 82, 10 01 99, Combustion waste: ash, slag, ash-slag mixtures Total carbon content High-temperature combustion with IR detection Range PN-G-04571:1998","methodology_zh":"总碳含量","parameters_zh":[{"name":"范围","range":"(0,5 – 30,0) %"}],"search_zh":"废物：代码 10 01 01、10 01 02、10 01 03、10 01 05、10 01 07、10 01 15、10 01 17、10 01 19、10 01 21、10 01 23、10 01 24、10 01 25、10 01 80、10 01 81、10 01 82、10 01 99；炉膛废物：灰、炉渣、灰渣混合料 总碳含量 高温燃烧红外检测法 范围 PN-G-04571:1998","technique_zh":"高温燃烧红外检测法","test_object_zh":"废物：代码 10 01 01、10 01 02、10 01 03、10 01 05、10 01 07、10 01 15、10 01 17、10 01 19、10 01 21、10 01 23、10 01 24、10 01 25、10 01 80、10 01 81、10 01 82、10 01 99；炉膛废物：灰、炉渣、灰渣混合料"},{"_id":"6a5dc9bbf1c10c8ce825e01d","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Odpady: kod 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 15, 10 01 17, 10 01 19, 10 01 21, 10 01 23, 10 01 24, 10 01 25, 10 01 80, 10 01 81, 10 01 82, 10 01 99, Odpady paleniskowe: popiół, żużel, mieszanki popiołowo- żużlowe","test_object_en":"Waste: code 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 15, 10 01 17, 10 01 19, 10 01 21, 10 01 23, 10 01 24, 10 01 25, 10 01 80, 10 01 81, 10 01 82, 10 01 99, Combustion waste: ash, slag, ash-slag mixtures","methodology":"Zawartość wilgoci analitycznej","methodology_en":"Analytical moisture content","parameters":[{"name":"Zakres","range":"(0,10 – 10,0) %"}],"parameters_en":[{"name":"Range","range":"(0,10 – 10,0) %"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)"],"technique_en":"Thermogravimetric method (TGA)","computed":[],"computed_en":[],"activity":"Zawartość wilgoci analitycznej\nZakres (0,10 – 10,0) %\nMetoda termograwimetryczna (TGA)","reference":"PN-G-04560:1998","norm_bases":["PN-G-04560:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady: kod 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 15, 10 01 17, 10 01 19, 10 01 21, 10 01 23, 10 01 24, 10 01 25, 10 01 80, 10 01 81, 10 01 82, 10 01 99, Odpady paleniskowe: popiół, żużel, mieszanki popiołowo- żużlowe Zawartość wilgoci analitycznej\nZakres (0,10 – 10,0) %\nMetoda termograwimetryczna (TGA) PN-G-04560:1998 Odpady: kod 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 15, 10 01 17, 10 01 19, 10 01 21, 10 01 23, 10 01 24, 10 01 25, 10 01 80, 10 01 81, 10 01 82, 10 01 99, Odpady paleniskowe: popiol, zuzel, mieszanki popiolowo- zuzlowe Zawartosc wilgoci analitycznej\nZakres (0,10 – 10,0) %\nMetoda termograwimetryczna (TGA) PN-G-04560:1998","categories":["environment"],"row_index":81,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste: code 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 15, 10 01 17, 10 01 19, 10 01 21, 10 01 23, 10 01 24, 10 01 25, 10 01 80, 10 01 81, 10 01 82, 10 01 99, Combustion waste: ash, slag, ash-slag mixtures Analytical moisture content Thermogravimetric method (TGA) Range PN-G-04560:1998","parameters_zh":[{"name":"范围","range":"(0,10 – 10,0) %"}],"search_zh":"废物：代码 10 01 01、10 01 02、10 01 03、10 01 05、10 01 07、10 01 15、10 01 17、10 01 19、10 01 21、10 01 23、10 01 24、10 01 25、10 01 80、10 01 81、10 01 82、10 01 99；炉膛废物：灰、炉渣、灰渣混合料 分析水分含量 热重法（TGA） 范围 PN-G-04560:1998","technique_zh":"热重法（TGA）","methodology_zh":"分析水分含量","test_object_zh":"废物：代码 10 01 01、10 01 02、10 01 03、10 01 05、10 01 07、10 01 15、10 01 17、10 01 19、10 01 21、10 01 23、10 01 24、10 01 25、10 01 80、10 01 81、10 01 82、10 01 99；炉膛废物：灰、炉渣、灰渣混合料"},{"_id":"6a5dc9bbf1c10c8ce825e01e","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Odpady: kod 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 15, 10 01 17, 10 01 19, 10 01 21, 10 01 23, 10 01 24, 10 01 25, 10 01 80, 10 01 81, 10 01 82, 10 01 99, Odpady paleniskowe: popiół, żużel, mieszanki popiołowo- żużlowe","test_object_en":"Waste: code 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 15, 10 01 17, 10 01 19, 10 01 21, 10 01 23, 10 01 24, 10 01 25, 10 01 80, 10 01 81, 10 01 82, 10 01 99, Combustion waste: ash, slag, ash-slag mixtures","methodology":"Zawartość wilgoci całkowitej","methodology_en":"Total moisture content","parameters":[{"name":"Zakres","range":"(0,10 – 35,0) %"}],"parameters_en":[{"name":"Range","range":"(0,10 – 35,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość wilgoci całkowitej\nZakres (0,10 – 35,0) %\nMetoda wagowa","reference":"PN-ISO 589:2006 met. B1","norm_bases":["PN-ISO 589:2006 met. B1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady: kod 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 15, 10 01 17, 10 01 19, 10 01 21, 10 01 23, 10 01 24, 10 01 25, 10 01 80, 10 01 81, 10 01 82, 10 01 99, Odpady paleniskowe: popiół, żużel, mieszanki popiołowo- żużlowe Zawartość wilgoci całkowitej\nZakres (0,10 – 35,0) %\nMetoda wagowa PN-ISO 589:2006 met. B1 Odpady: kod 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 15, 10 01 17, 10 01 19, 10 01 21, 10 01 23, 10 01 24, 10 01 25, 10 01 80, 10 01 81, 10 01 82, 10 01 99, Odpady paleniskowe: popiol, zuzel, mieszanki popiolowo- zuzlowe Zawartosc wilgoci calkowitej\nZakres (0,10 – 35,0) %\nMetoda wagowa PN-ISO 589:2006 met. B1","categories":["environment"],"row_index":82,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste: code 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 15, 10 01 17, 10 01 19, 10 01 21, 10 01 23, 10 01 24, 10 01 25, 10 01 80, 10 01 81, 10 01 82, 10 01 99, Combustion waste: ash, slag, ash-slag mixtures Total moisture content Gravimetric method Range PN-ISO 589:2006 met. B1","methodology_zh":"全水分含量","parameters_zh":[{"name":"范围","range":"(0,10 – 35,0) %"}],"search_zh":"废物：代码 10 01 01、10 01 02、10 01 03、10 01 05、10 01 07、10 01 15、10 01 17、10 01 19、10 01 21、10 01 23、10 01 24、10 01 25、10 01 80、10 01 81、10 01 82、10 01 99；炉膛废物：灰、炉渣、灰渣混合料 全水分含量 重量法 范围 PN-ISO 589:2006 met. B1","technique_zh":"重量法","test_object_zh":"废物：代码 10 01 01、10 01 02、10 01 03、10 01 05、10 01 07、10 01 15、10 01 17、10 01 19、10 01 21、10 01 23、10 01 24、10 01 25、10 01 80、10 01 81、10 01 82、10 01 99；炉膛废物：灰、炉渣、灰渣混合料"},{"_id":"6a5dc9bbf1c10c8ce825e01f","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Odpady: kod 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 15, 10 01 17, 10 01 19, 10 01 21, 10 01 23, 10 01 24, 10 01 25, 10 01 80, 10 01 81, 10 01 82, 10 01 99, Odpady paleniskowe: popiół, żużel, mieszanki popiołowo- żużlowe","test_object_en":"Waste: code 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 15, 10 01 17, 10 01 19, 10 01 21, 10 01 23, 10 01 24, 10 01 25, 10 01 80, 10 01 81, 10 01 82, 10 01 99, Combustion waste: ash, slag, ash-slag mixtures","methodology":"Zawartość wilgoci całkowitej","methodology_en":"Total moisture content","parameters":[{"name":"Zakres","range":"(0,10 – 50,0) %"}],"parameters_en":[{"name":"Range","range":"(0,10 – 50,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość wilgoci całkowitej\nZakres (0,10 – 50,0) %\nMetoda wagowa","reference":"CEN/TS 15414-1:2010","norm_bases":["CEN/TS 15414-1:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady: kod 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 15, 10 01 17, 10 01 19, 10 01 21, 10 01 23, 10 01 24, 10 01 25, 10 01 80, 10 01 81, 10 01 82, 10 01 99, Odpady paleniskowe: popiół, żużel, mieszanki popiołowo- żużlowe Zawartość wilgoci całkowitej\nZakres (0,10 – 50,0) %\nMetoda wagowa CEN/TS 15414-1:2010 Odpady: kod 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 15, 10 01 17, 10 01 19, 10 01 21, 10 01 23, 10 01 24, 10 01 25, 10 01 80, 10 01 81, 10 01 82, 10 01 99, Odpady paleniskowe: popiol, zuzel, mieszanki popiolowo- zuzlowe Zawartosc wilgoci calkowitej\nZakres (0,10 – 50,0) %\nMetoda wagowa CEN/TS 15414-1:2010","categories":["environment"],"row_index":83,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste: code 10 01 01, 10 01 02, 10 01 03, 10 01 05, 10 01 07, 10 01 15, 10 01 17, 10 01 19, 10 01 21, 10 01 23, 10 01 24, 10 01 25, 10 01 80, 10 01 81, 10 01 82, 10 01 99, Combustion waste: ash, slag, ash-slag mixtures Total moisture content Gravimetric method Range CEN/TS 15414-1:2010","methodology_zh":"全水分含量","parameters_zh":[{"name":"范围","range":"(0,10 – 50,0) %"}],"search_zh":"废物：代码 10 01 01、10 01 02、10 01 03、10 01 05、10 01 07、10 01 15、10 01 17、10 01 19、10 01 21、10 01 23、10 01 24、10 01 25、10 01 80、10 01 81、10 01 82、10 01 99；炉膛废物：灰、炉渣、灰渣混合料 全水分含量 重量法 范围 CEN/TS 15414-1:2010","technique_zh":"重量法","test_object_zh":"废物：代码 10 01 01、10 01 02、10 01 03、10 01 05、10 01 07、10 01 15、10 01 17、10 01 19、10 01 21、10 01 23、10 01 24、10 01 25、10 01 80、10 01 81、10 01 82、10 01 99；炉膛废物：灰、炉渣、灰渣混合料"},{"_id":"6a5dc9bbf1c10c8ce825e020","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Surowce, materiały ceramiczne, Materiały budowlane","test_object_en":"Raw materials, ceramic materials, Building materials","methodology":"Zawartość węgla pierwiastkowego","methodology_en":"Elemental carbon content","parameters":[{"name":"Zakres","range":"(0,10 – 78,0) %"}],"parameters_en":[{"name":"Range","range":"(0,10 – 78,0) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"technique_en":"High-temperature combustion with IR detection","computed":[],"computed_en":[],"activity":"Zawartość węgla pierwiastkowego\nZakres (0,10 – 78,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PB 32 wydanie 2 z dnia 01.10.2021 r.","norm_bases":["PB 32 wydanie 2 z dnia 01.10.2021 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Surowce, materiały ceramiczne, Materiały budowlane Zawartość węgla pierwiastkowego\nZakres (0,10 – 78,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR PB 32 wydanie 2 z dnia 01.10.2021 r. Surowce, materialy ceramiczne, Materialy budowlane Zawartosc wegla pierwiastkowego\nZakres (0,10 – 78,0) %\nMetoda wysokotemperaturowego spalania z detekcja IR PB 32 wydanie 2 z dnia 01.10.2021 r.","categories":["materials","construction"],"row_index":84,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Raw materials, ceramic materials, Building materials Elemental carbon content High-temperature combustion with IR detection Range PB 32 wydanie 2 z dnia 01.10.2021 r.","parameters_zh":[{"name":"范围","range":"(0,10 – 78,0) %"}],"search_zh":"高温燃烧红外检测法 范围 PB 32 wydanie 2 z dnia 01.10.2021 r.","technique_zh":"高温燃烧红外检测法"},{"_id":"6a5dc9bbf1c10c8ce825e021","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Surowce, materiały ceramiczne, Materiały budowlane","test_object_en":"Raw materials, ceramic materials, Building materials","methodology":"Zawartość węgla całkowitego TC","methodology_en":"Total carbon TC content","parameters":[{"name":"Zakres","range":"(0,10 – 78,0) %"}],"parameters_en":[{"name":"Range","range":"(0,10 – 78,0) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"technique_en":"High-temperature combustion with IR detection","computed":[],"computed_en":[],"activity":"Zawartość węgla całkowitego TC\nZakres (0,10 – 78,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN 15936:2022-07 metoda A","norm_bases":["PN-EN 15936:2022-07 metoda A"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Surowce, materiały ceramiczne, Materiały budowlane Zawartość węgla całkowitego TC\nZakres (0,10 – 78,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN 15936:2022-07 metoda A Surowce, materialy ceramiczne, Materialy budowlane Zawartosc wegla calkowitego TC\nZakres (0,10 – 78,0) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN 15936:2022-07 metoda A","categories":["materials","construction"],"row_index":85,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Raw materials, ceramic materials, Building materials Total carbon TC content High-temperature combustion with IR detection Range PN-EN 15936:2022-07 metoda A","parameters_zh":[{"name":"范围","range":"(0,10 – 78,0) %"}],"search_zh":"总碳含量 TC 高温燃烧红外检测法 范围 PN-EN 15936:2022-07 metoda A","technique_zh":"高温燃烧红外检测法","methodology_zh":"总碳含量 TC"},{"_id":"6a5dc9bbf1c10c8ce825e022","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Surowce, materiały ceramiczne, Materiały budowlane","test_object_en":"Raw materials, ceramic materials, Building materials","methodology":"Zawartość węgla organicznego TOC (z obliczeń)","methodology_en":"Organic carbon content TOC (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość węgla organicznego TOC (z obliczeń)","reference":"PN-EN 15936:2022-07 metoda A","norm_bases":["PN-EN 15936:2022-07 metoda A"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Surowce, materiały ceramiczne, Materiały budowlane Zawartość węgla organicznego TOC (z obliczeń) PN-EN 15936:2022-07 metoda A Surowce, materialy ceramiczne, Materialy budowlane Zawartosc wegla organicznego TOC (z obliczen) PN-EN 15936:2022-07 metoda A","categories":["materials","construction"],"row_index":86,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Raw materials, ceramic materials, Building materials Organic carbon content TOC (calculated) PN-EN 15936:2022-07 metoda A"},{"_id":"6a5dc9bbf1c10c8ce825e023","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Nawęglacz","test_object_en":"Recarburiser","methodology":"Zawartość wilgoci całkowitej","methodology_en":"Total moisture content","parameters":[{"name":"Zakres","range":"(0,4 – 2,4)%"}],"parameters_en":[{"name":"Range","range":"(0,4 – 2,4)%"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość wilgoci całkowitej\nZakres (0,4 – 2,4)%\nMetoda wagowa","reference":"PN-ISO 589:2006 met. B1","norm_bases":["PN-ISO 589:2006 met. B1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Nawęglacz Zawartość wilgoci całkowitej\nZakres (0,4 – 2,4)%\nMetoda wagowa PN-ISO 589:2006 met. B1 Naweglacz Zawartosc wilgoci calkowitej\nZakres (0,4 – 2,4)%\nMetoda wagowa PN-ISO 589:2006 met. B1","categories":["other"],"row_index":87,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Recarburiser Total moisture content Gravimetric method Range PN-ISO 589:2006 met. B1","methodology_zh":"全水分含量","parameters_zh":[{"name":"范围","range":"(0,4 – 2,4)%"}],"search_zh":"增碳剂 全水分含量 重量法 范围 PN-ISO 589:2006 met. B1","technique_zh":"重量法","test_object_zh":"增碳剂"},{"_id":"6a5dc9bbf1c10c8ce825e024","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Nawęglacz","test_object_en":"Recarburiser","methodology":"Zawartość wilgoci analitycznej","methodology_en":"Analytical moisture content","parameters":[{"name":"Zakres","range":"(0,10 – 2,25)%"},{"name":"Zawartość popiołu"},{"name":"Zakres","range":"(1,60 – 33,00)%"}],"parameters_en":[{"name":"Range","range":"(0,10 – 2,25)%"},{"name":"Ash content"},{"name":"Range","range":"(1,60 – 33,00)%"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)"],"technique_en":"Thermogravimetric method (TGA)","computed":[],"computed_en":[],"activity":"Zawartość wilgoci analitycznej\nZakres:\nZakres (0,10 – 2,25)%\nZawartość popiołu\nZakres (1,60 – 33,00)%\nMetoda termograwimetryczna (TGA)","reference":"PN-G-04560:1998","norm_bases":["PN-G-04560:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Nawęglacz Zawartość wilgoci analitycznej\nZakres:\nZakres (0,10 – 2,25)%\nZawartość popiołu\nZakres (1,60 – 33,00)%\nMetoda termograwimetryczna (TGA) PN-G-04560:1998 Naweglacz Zawartosc wilgoci analitycznej\nZakres:\nZakres (0,10 – 2,25)%\nZawartosc popiolu\nZakres (1,60 – 33,00)%\nMetoda termograwimetryczna (TGA) PN-G-04560:1998","categories":["other"],"row_index":88,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Recarburiser Analytical moisture content Thermogravimetric method (TGA) Range Ash content Range PN-G-04560:1998","parameters_zh":[{"name":"范围","range":"(0,10 – 2,25)%"},{"name":"灰分含量"},{"name":"范围","range":"(1,60 – 33,00)%"}],"search_zh":"增碳剂 分析水分含量 热重法（TGA） 范围 灰分含量 范围 PN-G-04560:1998","technique_zh":"热重法（TGA）","methodology_zh":"分析水分含量","test_object_zh":"增碳剂"},{"_id":"6a5dc9bbf1c10c8ce825e025","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Nawęglacz","test_object_en":"Recarburiser","methodology":"Zawartość węgla całkowitego","methodology_en":"Total carbon content","parameters":[{"name":"Zakres","range":"(60,0 – 98,0)%"}],"parameters_en":[{"name":"Range","range":"(60,0 – 98,0)%"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"technique_en":"High-temperature combustion with IR detection","computed":[],"computed_en":[],"activity":"Zawartość węgla całkowitego\nZakres (60,0 – 98,0)%\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04571:1998","norm_bases":["PN-G-04571:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Nawęglacz Zawartość węgla całkowitego\nZakres (60,0 – 98,0)%\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04571:1998 Naweglacz Zawartosc wegla calkowitego\nZakres (60,0 – 98,0)%\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04571:1998","categories":["other"],"row_index":89,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Recarburiser Total carbon content High-temperature combustion with IR detection Range PN-G-04571:1998","methodology_zh":"总碳含量","parameters_zh":[{"name":"范围","range":"(60,0 – 98,0)%"}],"search_zh":"增碳剂 总碳含量 高温燃烧红外检测法 范围 PN-G-04571:1998","technique_zh":"高温燃烧红外检测法","test_object_zh":"增碳剂"},{"_id":"6a5dc9bbf1c10c8ce825e026","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Nawęglacz","test_object_en":"Recarburiser","methodology":"Zawartość siarki całkowitej","methodology_en":"Total sulfur content","parameters":[{"name":"Zakres","range":"(0,10 – 0,95)%"}],"parameters_en":[{"name":"Range","range":"(0,10 – 0,95)%"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"technique_en":"High-temperature combustion with IR detection","computed":[],"computed_en":[],"activity":"Zawartość siarki całkowitej\nZakres (0,10 – 0,95)%\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04584:2001","norm_bases":["PN-G-04584:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Nawęglacz Zawartość siarki całkowitej\nZakres (0,10 – 0,95)%\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04584:2001 Naweglacz Zawartosc siarki calkowitej\nZakres (0,10 – 0,95)%\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04584:2001","categories":["other"],"row_index":90,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Recarburiser Total sulfur content High-temperature combustion with IR detection Range PN-G-04584:2001","methodology_zh":"全硫含量","parameters_zh":[{"name":"范围","range":"(0,10 – 0,95)%"}],"search_zh":"增碳剂 全硫含量 高温燃烧红外检测法 范围 PN-G-04584:2001","technique_zh":"高温燃烧红外检测法","test_object_zh":"增碳剂"},{"_id":"6a5dc9bbf1c10c8ce825e027","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Nawęglacz","test_object_en":"Recarburiser","methodology":"Zawartość części lotnych","methodology_en":"Volatile matter content","parameters":[{"name":"Zakres","range":"(1,00 – 2,10)%"}],"parameters_en":[{"name":"Range","range":"(1,00 – 2,10)%"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość części lotnych\nZakres (1,00 – 2,10)%\nMetoda wagowa","reference":"PN-G-04516:1998","norm_bases":["PN-G-04516:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Nawęglacz Zawartość części lotnych\nZakres (1,00 – 2,10)%\nMetoda wagowa PN-G-04516:1998 Naweglacz Zawartosc czesci lotnych\nZakres (1,00 – 2,10)%\nMetoda wagowa PN-G-04516:1998","categories":["other"],"row_index":91,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Recarburiser Volatile matter content Gravimetric method Range PN-G-04516:1998","parameters_zh":[{"name":"范围","range":"(1,00 – 2,10)%"}],"search_zh":"增碳剂 挥发分含量 重量法 范围 PN-G-04516:1998","technique_zh":"重量法","methodology_zh":"挥发分含量","test_object_zh":"增碳剂"},{"_id":"6a5dc9bbf1c10c8ce825e028","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Materiały i surowce ogniotrwałe","test_object_en":"Refractory materials and raw materials","methodology":"Gęstość rzeczywista","methodology_en":"True density","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Gęstość rzeczywista","reference":"PN-EN 993-2:1997+A1:2004","norm_bases":["PN-EN 993-2:1997+A1:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały i surowce ogniotrwałe Gęstość rzeczywista PN-EN 993-2:1997+A1:2004 Materialy i surowce ogniotrwale Gestosc rzeczywista PN-EN 993-2:1997+A1:2004","categories":["materials"],"row_index":92,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Refractory materials and raw materials True density PN-EN 993-2:1997+A1:2004","search_zh":"耐火材料与原料 PN-EN 993-2:1997+A1:2004","test_object_zh":"耐火材料与原料"},{"_id":"6a5dc9bbf1c10c8ce825e029","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Materiały i surowce ogniotrwałe","test_object_en":"Refractory materials and raw materials","methodology":"Gęstość nasypowa","methodology_en":"Bulk density","parameters":[],"parameters_en":[],"technique":"Metoda A i B","techniques":["Metoda A i B"],"technique_en":"Method A and B","computed":[],"computed_en":[],"activity":"Gęstość nasypowa\nMetoda A i B","reference":"PN-80/C-04532","norm_bases":["PN-80/C-04532"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały i surowce ogniotrwałe Gęstość nasypowa\nMetoda A i B PN-80/C-04532 Materialy i surowce ogniotrwale Gestosc nasypowa\nMetoda A i B PN-80/C-04532","categories":["materials"],"row_index":93,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Refractory materials and raw materials Bulk density Method A and B PN-80/C-04532","methodology_zh":"堆积密度","search_zh":"耐火材料与原料 堆积密度 PN-80/C-04532","test_object_zh":"耐火材料与原料"},{"_id":"6a5dc9bbf1c10c8ce825e02a","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Materiały i surowce ogniotrwałe","test_object_en":"Refractory materials and raw materials","methodology":"Porowatość otwarta, Nasiąkliwość","methodology_en":"Open porosity, Water absorption","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Porowatość otwarta, Nasiąkliwość","reference":"PB 05 wydanie 5 z dnia 01.08.2025 r.","norm_bases":["PB 05 wydanie 5 z dnia 01.08.2025 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały i surowce ogniotrwałe Porowatość otwarta, Nasiąkliwość PB 05 wydanie 5 z dnia 01.08.2025 r. Materialy i surowce ogniotrwale Porowatosc otwarta, Nasiakliwosc PB 05 wydanie 5 z dnia 01.08.2025 r.","categories":["materials"],"row_index":94,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Refractory materials and raw materials Open porosity, Water absorption PB 05 wydanie 5 z dnia 01.08.2025 r.","search_zh":"耐火材料与原料 PB 05 wydanie 5 z dnia 01.08.2025 r.","test_object_zh":"耐火材料与原料"},{"_id":"6a5dc9bbf1c10c8ce825e02b","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Materiały i surowce ogniotrwałe","test_object_en":"Refractory materials and raw materials","methodology":"Gęstość pozorna","methodology_en":"Apparent density","parameters":[],"parameters_en":[],"technique":"Metoda próżniowa","techniques":["Metoda próżniowa"],"technique_en":"Vacuum method","computed":[],"computed_en":[],"activity":"Gęstość pozorna\nMetoda próżniowa","reference":"PN-EN ISO 8840:2024-12","norm_bases":["PN-EN ISO 8840:2024-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały i surowce ogniotrwałe Gęstość pozorna\nMetoda próżniowa PN-EN ISO 8840:2024-12 Materialy i surowce ogniotrwale Gestosc pozorna\nMetoda prozniowa PN-EN ISO 8840:2024-12","categories":["materials"],"row_index":95,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Refractory materials and raw materials Apparent density Vacuum method PN-EN ISO 8840:2024-12","search_zh":"耐火材料与原料 表观密度 真空法 PN-EN ISO 8840:2024-12","technique_zh":"真空法","methodology_zh":"表观密度","test_object_zh":"耐火材料与原料"},{"_id":"6a5dc9bbf1c10c8ce825e02c","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Materiały ogniotrwałe","test_object_en":"Refractory materials","methodology":"Nasiąkliwość","methodology_en":"Water absorption","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Nasiąkliwość","reference":"PN-92/H-04185","norm_bases":["PN-92/H-04185"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały ogniotrwałe Nasiąkliwość PN-92/H-04185 Materialy ogniotrwale Nasiakliwosc PN-92/H-04185","categories":["materials"],"row_index":96,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Refractory materials Water absorption PN-92/H-04185","methodology_zh":"吸水率","search_zh":"吸水率 PN-92/H-04185"},{"_id":"6a5dc9bbf1c10c8ce825e02d","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Materiały ogniotrwałe","test_object_en":"Refractory materials","methodology":"Gęstość pozorna, Porowatość otwarta, Porowatość całkowita","methodology_en":"Apparent density, Open porosity, Total porosity","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Gęstość pozorna, Porowatość otwarta, Porowatość całkowita","reference":"PN-EN 993-1:2019-01","norm_bases":["PN-EN 993-1:2019-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały ogniotrwałe Gęstość pozorna, Porowatość otwarta, Porowatość całkowita PN-EN 993-1:2019-01 Materialy ogniotrwale Gestosc pozorna, Porowatosc otwarta, Porowatosc calkowita PN-EN 993-1:2019-01","categories":["materials"],"row_index":97,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Refractory materials Apparent density, Open porosity, Total porosity PN-EN 993-1:2019-01"},{"_id":"6a5dc9bbf1c10c8ce825e02e","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Materiały ogniotrwałe","test_object_en":"Refractory materials","methodology":"Wytrzymałość na ściskanie","methodology_en":"Compressive strength","parameters":[{"name":"Zakres siły","range":"(30 – 500) kN"}],"parameters_en":[{"name":"Force range","range":"(30 – 500) kN"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ściskanie\nZakres siły (30 – 500) kN","reference":"PN-EN 993-5:2019-01 | PN-EN ISO 8895:2007","norm_bases":["PN-EN 993-5:2019-01","PN-EN ISO 8895:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały ogniotrwałe Wytrzymałość na ściskanie\nZakres siły (30 – 500) kN PN-EN 993-5:2019-01 | PN-EN ISO 8895:2007 Materialy ogniotrwale Wytrzymalosc na sciskanie\nZakres sily (30 – 500) kN PN-EN 993-5:2019-01 | PN-EN ISO 8895:2007","categories":["materials"],"row_index":98,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Refractory materials Compressive strength Force range PN-EN 993-5:2019-01 | PN-EN ISO 8895:2007","methodology_zh":"抗压强度","parameters_zh":[{"name":"力值范围","range":"(30 – 500) kN"}],"search_zh":"抗压强度 力值范围 PN-EN 993-5:2019-01 | PN-EN ISO 8895:2007"},{"_id":"6a5dc9bbf1c10c8ce825e02f","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Izolacyjne materiały ogniotrwałe","test_object_en":"Insulating refractory materials","methodology":"Gęstość pozorna, Porowatość całkowita","methodology_en":"Apparent density, Total porosity","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Gęstość pozorna, Porowatość całkowita","reference":"PN-EN 1094-4:1998","norm_bases":["PN-EN 1094-4:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Izolacyjne materiały ogniotrwałe Gęstość pozorna, Porowatość całkowita PN-EN 1094-4:1998 Izolacyjne materialy ogniotrwale Gestosc pozorna, Porowatosc calkowita PN-EN 1094-4:1998","categories":["materials","construction"],"row_index":99,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Insulating refractory materials Apparent density, Total porosity PN-EN 1094-4:1998"},{"_id":"6a5dc9bbf1c10c8ce825e030","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Surowce ogniotrwałe, zaprawy","test_object_en":"Refractory raw materials, mortars","methodology":"Analiza sitowa","methodology_en":"Sieve analysis","parameters":[{"name":"Zakres","range":"(0,063 – 16) mm"}],"parameters_en":[{"name":"Range","range":"(0,063 – 16) mm"}],"technique":"Metoda przesiewania","techniques":["Metoda przesiewania"],"technique_en":"Sieving method","computed":[],"computed_en":[],"activity":"Analiza sitowa\nZakres (0,063 – 16) mm\nMetoda przesiewania","reference":"PN-EN ISO 1927-3:2013-06","norm_bases":["PN-EN ISO 1927-3:2013-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Surowce ogniotrwałe, zaprawy Analiza sitowa\nZakres (0,063 – 16) mm\nMetoda przesiewania PN-EN ISO 1927-3:2013-06 Surowce ogniotrwale, zaprawy Analiza sitowa\nZakres (0,063 – 16) mm\nMetoda przesiewania PN-EN ISO 1927-3:2013-06","categories":["other"],"row_index":100,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Refractory raw materials, mortars Sieve analysis Sieving method Range PN-EN ISO 1927-3:2013-06","parameters_zh":[{"name":"范围","range":"(0,063 – 16) mm"}],"search_zh":"筛分分析 筛分法 范围 PN-EN ISO 1927-3:2013-06","technique_zh":"筛分法","methodology_zh":"筛分分析"},{"_id":"6a5dc9bbf1c10c8ce825e031","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Żużle, surowce i wyroby ceramiczne, wyroby i materiały ogniotrwałe","test_object_en":"Slags, ceramic raw materials and products, refractory products and materials","methodology":"Zawartość wilgoci","methodology_en":"Moisture content","parameters":[{"name":"Zakres","range":"(0,1 – 60,0) %"}],"parameters_en":[{"name":"Range","range":"(0,1 – 60,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość wilgoci\nZakres (0,1 – 60,0) %\nMetoda wagowa","reference":"PN-EN ISO 1927-3:2013-06","norm_bases":["PN-EN ISO 1927-3:2013-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Żużle, surowce i wyroby ceramiczne, wyroby i materiały ogniotrwałe Zawartość wilgoci\nZakres (0,1 – 60,0) %\nMetoda wagowa PN-EN ISO 1927-3:2013-06 Zuzle, surowce i wyroby ceramiczne, wyroby i materialy ogniotrwale Zawartosc wilgoci\nZakres (0,1 – 60,0) %\nMetoda wagowa PN-EN ISO 1927-3:2013-06","categories":["materials"],"row_index":101,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Slags, ceramic raw materials and products, refractory products and materials Moisture content Gravimetric method Range PN-EN ISO 1927-3:2013-06","parameters_zh":[{"name":"范围","range":"(0,1 – 60,0) %"}],"search_zh":"水分含量 重量法 范围 PN-EN ISO 1927-3:2013-06","technique_zh":"重量法","methodology_zh":"水分含量"},{"_id":"6a5dc9bbf1c10c8ce825e032","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Nieformowane wyroby ogniotrwałe","test_object_en":"Unshaped refractory products","methodology":"Rozkład uziarnienia","methodology_en":"Particle size distribution","parameters":[{"name":"Zakres","range":"(0,063 – 16) mm"}],"parameters_en":[{"name":"Range","range":"(0,063 – 16) mm"}],"technique":"Metoda przesiewania","techniques":["Metoda przesiewania"],"technique_en":"Sieving method","computed":[],"computed_en":[],"activity":"Rozkład uziarnienia\nZakres (0,063 – 16) mm\nMetoda przesiewania","reference":"PN-EN ISO 1927-3:2013-06","norm_bases":["PN-EN ISO 1927-3:2013-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Nieformowane wyroby ogniotrwałe Rozkład uziarnienia\nZakres (0,063 – 16) mm\nMetoda przesiewania PN-EN ISO 1927-3:2013-06 Nieformowane wyroby ogniotrwale Rozklad uziarnienia\nZakres (0,063 – 16) mm\nMetoda przesiewania PN-EN ISO 1927-3:2013-06","categories":["other"],"row_index":102,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Unshaped refractory products Particle size distribution Sieving method Range PN-EN ISO 1927-3:2013-06","parameters_zh":[{"name":"范围","range":"(0,063 – 16) mm"}],"search_zh":"不定形耐火制品 筛分法 范围 PN-EN ISO 1927-3:2013-06","technique_zh":"筛分法","test_object_zh":"不定形耐火制品"},{"_id":"6a5dc9bbf1c10c8ce825e033","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Nieformowane wyroby ogniotrwałe","test_object_en":"Unshaped refractory products","methodology":"Geometryczna gęstość pozorna","methodology_en":"Geometric apparent density","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Geometryczna gęstość pozorna","reference":"PN-EN ISO 1927-6:2013-06","norm_bases":["PN-EN ISO 1927-6:2013-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Nieformowane wyroby ogniotrwałe Geometryczna gęstość pozorna PN-EN ISO 1927-6:2013-06 Nieformowane wyroby ogniotrwale Geometryczna gestosc pozorna PN-EN ISO 1927-6:2013-06","categories":["other"],"row_index":103,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Unshaped refractory products Geometric apparent density PN-EN ISO 1927-6:2013-06","search_zh":"不定形耐火制品 PN-EN ISO 1927-6:2013-06","test_object_zh":"不定形耐火制品"},{"_id":"6a5dc9bbf1c10c8ce825e034","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Nieformowane wyroby ogniotrwałe","test_object_en":"Unshaped refractory products","methodology":"Gęstość pozorna","methodology_en":"Apparent density","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Gęstość pozorna","reference":"PN-EN ISO 1927-6:2013-06","norm_bases":["PN-EN ISO 1927-6:2013-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Nieformowane wyroby ogniotrwałe Gęstość pozorna PN-EN ISO 1927-6:2013-06 Nieformowane wyroby ogniotrwale Gestosc pozorna PN-EN ISO 1927-6:2013-06","categories":["other"],"row_index":104,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Unshaped refractory products Apparent density PN-EN ISO 1927-6:2013-06","methodology_zh":"表观密度","search_zh":"不定形耐火制品 表观密度 PN-EN ISO 1927-6:2013-06","test_object_zh":"不定形耐火制品"},{"_id":"6a5dc9bbf1c10c8ce825e035","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Nieformowane wyroby ogniotrwałe","test_object_en":"Unshaped refractory products","methodology":"Porowatość otwarta","methodology_en":"Open porosity","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Porowatość otwarta","reference":"PN-EN ISO 1927-6:2013-06","norm_bases":["PN-EN ISO 1927-6:2013-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Nieformowane wyroby ogniotrwałe Porowatość otwarta PN-EN ISO 1927-6:2013-06 Nieformowane wyroby ogniotrwale Porowatosc otwarta PN-EN ISO 1927-6:2013-06","categories":["other"],"row_index":105,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Unshaped refractory products Open porosity PN-EN ISO 1927-6:2013-06","search_zh":"不定形耐火制品 PN-EN ISO 1927-6:2013-06","test_object_zh":"不定形耐火制品"},{"_id":"6a5dc9bbf1c10c8ce825e036","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Nieformowane wyroby ogniotrwałe","test_object_en":"Unshaped refractory products","methodology":"Porowatość całkowita","methodology_en":"Total porosity","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Porowatość całkowita","reference":"PN-EN ISO 1927-6:2013-06","norm_bases":["PN-EN ISO 1927-6:2013-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Nieformowane wyroby ogniotrwałe Porowatość całkowita PN-EN ISO 1927-6:2013-06 Nieformowane wyroby ogniotrwale Porowatosc calkowita PN-EN ISO 1927-6:2013-06","categories":["other"],"row_index":106,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Unshaped refractory products Total porosity PN-EN ISO 1927-6:2013-06","search_zh":"不定形耐火制品 PN-EN ISO 1927-6:2013-06","test_object_zh":"不定形耐火制品"},{"_id":"6a5dc9bbf1c10c8ce825e037","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Nieformowane wyroby ogniotrwałe","test_object_en":"Unshaped refractory products","methodology":"Wytrzymałość na ściskanie","methodology_en":"Compressive strength","parameters":[{"name":"Zakres siły","range":"(30 – 500) kN"},{"name":"Próbki o wymiarach 230x114x64mm Próbki o wymiarach 230x64x64mm"}],"parameters_en":[{"name":"Force range","range":"(30 – 500) kN"},{"name":"Specimens with dimensions 230x114x64mm Specimens with dimensions 230x64x64mm"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ściskanie\nZakres:\nZakres siły (30 – 500) kN\nPróbki o wymiarach 230x114x64mm Próbki o wymiarach 230x64x64mm","reference":"PN-EN ISO 1927-6:2013-06","norm_bases":["PN-EN ISO 1927-6:2013-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Nieformowane wyroby ogniotrwałe Wytrzymałość na ściskanie\nZakres:\nZakres siły (30 – 500) kN\nPróbki o wymiarach 230x114x64mm Próbki o wymiarach 230x64x64mm PN-EN ISO 1927-6:2013-06 Nieformowane wyroby ogniotrwale Wytrzymalosc na sciskanie\nZakres:\nZakres sily (30 – 500) kN\nProbki o wymiarach 230x114x64mm Probki o wymiarach 230x64x64mm PN-EN ISO 1927-6:2013-06","categories":["other"],"row_index":107,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Unshaped refractory products Compressive strength Force range Specimens with dimensions 230x114x64mm Specimens with dimensions 230x64x64mm PN-EN ISO 1927-6:2013-06","methodology_zh":"抗压强度","parameters_zh":[{"name":"力值范围","range":"(30 – 500) kN"},{"name":"Próbki o wymiarach 230x114x64mm Próbki o wymiarach 230x64x64mm"}],"search_zh":"不定形耐火制品 抗压强度 力值范围 PN-EN ISO 1927-6:2013-06","test_object_zh":"不定形耐火制品"},{"_id":"6a5dc9bbf1c10c8ce825e038","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Nieformowane wyroby ogniotrwałe","test_object_en":"Unshaped refractory products","methodology":"Trwała zmiana liniowa","methodology_en":"Permanent linear change","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Trwała zmiana liniowa","reference":"PN-EN ISO 1927-6:2013-06","norm_bases":["PN-EN ISO 1927-6:2013-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Nieformowane wyroby ogniotrwałe Trwała zmiana liniowa PN-EN ISO 1927-6:2013-06 Nieformowane wyroby ogniotrwale Trwala zmiana liniowa PN-EN ISO 1927-6:2013-06","categories":["other"],"row_index":108,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Unshaped refractory products Permanent linear change PN-EN ISO 1927-6:2013-06","search_zh":"不定形耐火制品 PN-EN ISO 1927-6:2013-06","test_object_zh":"不定形耐火制品"},{"_id":"6a5dc9bbf1c10c8ce825e039","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Elementy murowe ceramiczne","test_object_en":"Clay masonry units","methodology":"Odporność na zamrażanie-odmrażanie","methodology_en":"Freeze-thaw resistance","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na zamrażanie-odmrażanie","reference":"PN-B-12012:2022-07","norm_bases":["PN-B-12012:2022-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy murowe ceramiczne Odporność na zamrażanie-odmrażanie PN-B-12012:2022-07 Elementy murowe ceramiczne Odpornosc na zamrazanie-odmrazanie PN-B-12012:2022-07","categories":["other"],"row_index":109,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Clay masonry units Freeze-thaw resistance PN-B-12012:2022-07","search_zh":"烧结黏土砌块 PN-B-12012:2022-07","test_object_zh":"烧结黏土砌块"},{"_id":"6a5dc9bbf1c10c8ce825e03a","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Dachówki ceramiczne","test_object_en":"Clay roof tiles","methodology":"Mrozoodporność","methodology_en":"Frost resistance","parameters":[{"name":"Zakres","range":"(od -19 do +17) oC"}],"parameters_en":[{"name":"Range","range":"(od -19 do +17) oC"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Mrozoodporność\nZakres (od -19 do +17) oC","reference":"PN-EN 539-2:2013-07","norm_bases":["PN-EN 539-2:2013-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Dachówki ceramiczne Mrozoodporność\nZakres (od -19 do +17) oC PN-EN 539-2:2013-07 Dachowki ceramiczne Mrozoodpornosc\nZakres (od -19 do +17) oC PN-EN 539-2:2013-07","categories":["construction"],"row_index":110,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Clay roof tiles Frost resistance Range PN-EN 539-2:2013-07","parameters_zh":[{"name":"范围","range":"(od -19 do +17) oC"}],"search_zh":"陶瓷屋面瓦 抗冻性 范围 PN-EN 539-2:2013-07","methodology_zh":"抗冻性","test_object_zh":"陶瓷屋面瓦"},{"_id":"6a5dc9bbf1c10c8ce825e03b","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Dachówki ceramiczne","test_object_en":"Clay roof tiles","methodology":"Absorpcja wody","methodology_en":"Water absorption","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Absorpcja wody","reference":"PN-EN 539-2:2013-07","norm_bases":["PN-EN 539-2:2013-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Dachówki ceramiczne Absorpcja wody PN-EN 539-2:2013-07 Dachowki ceramiczne Absorpcja wody PN-EN 539-2:2013-07","categories":["water","construction"],"row_index":111,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Clay roof tiles Water absorption PN-EN 539-2:2013-07","methodology_zh":"吸水率","search_zh":"陶瓷屋面瓦 吸水率 PN-EN 539-2:2013-07","test_object_zh":"陶瓷屋面瓦"},{"_id":"6a5dc9bbf1c10c8ce825e03c","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Kruszywa","test_object_en":"Aggregates","methodology":"Pobieranie próbek","methodology_en":"Sampling","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek","reference":"PN-EN 932-1:1999","norm_bases":["PN-EN 932-1:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywa Pobieranie próbek PN-EN 932-1:1999 Kruszywa Pobieranie probek PN-EN 932-1:1999","categories":["other"],"row_index":112,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Aggregates Sampling PN-EN 932-1:1999","methodology_zh":"样品采集","search_zh":"骨料 样品采集 PN-EN 932-1:1999","test_object_zh":"骨料"},{"_id":"6a5dc9bbf1c10c8ce825e03d","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Elementy murowe ceramiczne","test_object_en":"Clay masonry units","methodology":"Wytrzymałość na ściskanie","methodology_en":"Compressive strength","parameters":[{"name":"Zakres siły","range":"(100 – 5000) kN"}],"parameters_en":[{"name":"Force range","range":"(100 – 5000) kN"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ściskanie\nZakres siły (100 – 5000) kN","reference":"PN-EN 772-1+A1:2015-10","norm_bases":["PN-EN 772-1+A1:2015-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy murowe ceramiczne Wytrzymałość na ściskanie\nZakres siły (100 – 5000) kN PN-EN 772-1+A1:2015-10 Elementy murowe ceramiczne Wytrzymalosc na sciskanie\nZakres sily (100 – 5000) kN PN-EN 772-1+A1:2015-10","categories":["other"],"row_index":113,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Clay masonry units Compressive strength Force range PN-EN 772-1+A1:2015-10","methodology_zh":"抗压强度","parameters_zh":[{"name":"力值范围","range":"(100 – 5000) kN"}],"search_zh":"烧结黏土砌块 抗压强度 力值范围 PN-EN 772-1+A1:2015-10","test_object_zh":"烧结黏土砌块"},{"_id":"6a5dc9bbf1c10c8ce825e03e","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Elementy murowe ceramiczne","test_object_en":"Clay masonry units","methodology":"Objętość netto, Udział % drążeń","methodology_en":"Net volume, % of voids","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Objętość netto, Udział % drążeń","reference":"PN-EN 772-3:2000","norm_bases":["PN-EN 772-3:2000"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy murowe ceramiczne Objętość netto, Udział % drążeń PN-EN 772-3:2000 Elementy murowe ceramiczne Objetosc netto, Udzial % drazen PN-EN 772-3:2000","categories":["other"],"row_index":114,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Clay masonry units Net volume, % of voids PN-EN 772-3:2000","search_zh":"烧结黏土砌块 PN-EN 772-3:2000","test_object_zh":"烧结黏土砌块"},{"_id":"6a5dc9bbf1c10c8ce825e03f","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Elementy murowe ceramiczne","test_object_en":"Clay masonry units","methodology":"Absorpcja wody metodą gotowania","methodology_en":"Water absorption by the boiling method","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Absorpcja wody metodą gotowania","reference":"PN-EN 772-7:2000","norm_bases":["PN-EN 772-7:2000"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy murowe ceramiczne Absorpcja wody metodą gotowania PN-EN 772-7:2000 Elementy murowe ceramiczne Absorpcja wody metoda gotowania PN-EN 772-7:2000","categories":["water"],"row_index":115,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Clay masonry units Water absorption by the boiling method PN-EN 772-7:2000","search_zh":"烧结黏土砌块 PN-EN 772-7:2000","test_object_zh":"烧结黏土砌块"},{"_id":"6a5dc9bbf1c10c8ce825e040","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Elementy murowe ceramiczne","test_object_en":"Clay masonry units","methodology":"Objętość brutto, Objętość netto, Udział % drążeń","methodology_en":"Gross volume, Net volume, % of voids","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Objętość brutto, Objętość netto, Udział % drążeń","reference":"PN-EN 772-9:2006","norm_bases":["PN-EN 772-9:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy murowe ceramiczne Objętość brutto, Objętość netto, Udział % drążeń PN-EN 772-9:2006 Elementy murowe ceramiczne Objetosc brutto, Objetosc netto, Udzial % drazen PN-EN 772-9:2006","categories":["other"],"row_index":116,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Clay masonry units Gross volume, Net volume, % of voids PN-EN 772-9:2006","search_zh":"烧结黏土砌块 PN-EN 772-9:2006","test_object_zh":"烧结黏土砌块"},{"_id":"6a5dc9bbf1c10c8ce825e041","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Elementy murowe ceramiczne","test_object_en":"Clay masonry units","methodology":"Początkowa absorpcja wody","methodology_en":"Initial water absorption","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Początkowa absorpcja wody","reference":"PN-EN 772-11:2011","norm_bases":["PN-EN 772-11:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy murowe ceramiczne Początkowa absorpcja wody PN-EN 772-11:2011 Elementy murowe ceramiczne Poczatkowa absorpcja wody PN-EN 772-11:2011","categories":["water"],"row_index":117,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Clay masonry units Initial water absorption PN-EN 772-11:2011","search_zh":"烧结黏土砌块 初始吸水率 PN-EN 772-11:2011","test_object_zh":"烧结黏土砌块","methodology_zh":"初始吸水率"},{"_id":"6a5dc9bbf1c10c8ce825e042","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Elementy murowe ceramiczne","test_object_en":"Clay masonry units","methodology":"Masa w stanie suchym, Gęstość netto w stanie suchym, Gęstość brutto w stanie suchym","methodology_en":"Dry mass, Net dry density, Gross dry density","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Masa w stanie suchym, Gęstość netto w stanie suchym, Gęstość brutto w stanie suchym","reference":"PN-EN 772-13:2001","norm_bases":["PN-EN 772-13:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy murowe ceramiczne Masa w stanie suchym, Gęstość netto w stanie suchym, Gęstość brutto w stanie suchym PN-EN 772-13:2001 Elementy murowe ceramiczne Masa w stanie suchym, Gestosc netto w stanie suchym, Gestosc brutto w stanie suchym PN-EN 772-13:2001","categories":["other"],"row_index":118,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Clay masonry units Dry mass, Net dry density, Gross dry density PN-EN 772-13:2001","search_zh":"烧结黏土砌块 PN-EN 772-13:2001","test_object_zh":"烧结黏土砌块"},{"_id":"6a5dc9bbf1c10c8ce825e043","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Elementy murowe ceramiczne","test_object_en":"Clay masonry units","methodology":"Wymiary:","methodology_en":"Dimensions:","parameters":[{"name":"długość, szerokość, wysokość, równoległość powierzchni kładzenia, płaskość powierzchni kładzenia"},{"name":"Kształt i budowa: grubość ścianek zewnętrznych, wewnętrznych, głębokość otworów łączna grubość ścianek wewnętrznych i zewnętrznych"}],"parameters_en":[{"name":"length, width, height, parallelism of bed faces, flatness of bed faces"},{"name":"Shape and structure: thickness of external and internal walls, depth of holes total thickness of internal and external walls"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wymiary:\nZakres:\ndługość, szerokość, wysokość, równoległość powierzchni kładzenia, płaskość powierzchni kładzenia\nKształt i budowa: grubość ścianek zewnętrznych, wewnętrznych, głębokość otworów łączna grubość ścianek wewnętrznych i zewnętrznych","reference":"PN-EN 772-16:2011","norm_bases":["PN-EN 772-16:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy murowe ceramiczne Wymiary:\nZakres:\ndługość, szerokość, wysokość, równoległość powierzchni kładzenia, płaskość powierzchni kładzenia\nKształt i budowa: grubość ścianek zewnętrznych, wewnętrznych, głębokość otworów łączna grubość ścianek wewnętrznych i zewnętrznych PN-EN 772-16:2011 Elementy murowe ceramiczne Wymiary:\nZakres:\ndlugosc, szerokosc, wysokosc, rownoleglosc powierzchni kladzenia, plaskosc powierzchni kladzenia\nKsztalt i budowa: grubosc scianek zewnetrznych, wewnetrznych, glebokosc otworow laczna grubosc scianek wewnetrznych i zewnetrznych PN-EN 772-16:2011","categories":["other"],"row_index":119,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Clay masonry units Dimensions: length, width, height, parallelism of bed faces, flatness of bed faces Shape and structure: thickness of external and internal walls, depth of holes total thickness of internal and external walls PN-EN 772-16:2011","search_zh":"烧结黏土砌块 PN-EN 772-16:2011","test_object_zh":"烧结黏土砌块"},{"_id":"6a5dc9bbf1c10c8ce825e044","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Elementy murowe ceramiczne","test_object_en":"Clay masonry units","methodology":"Płaskość powierzchni licowych","methodology_en":"Flatness of the facing surfaces","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Płaskość powierzchni licowych","reference":"PN-EN 772-20:2002+A1:2005","norm_bases":["PN-EN 772-20:2002+A1:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy murowe ceramiczne Płaskość powierzchni licowych PN-EN 772-20:2002+A1:2005 Elementy murowe ceramiczne Plaskosc powierzchni licowych PN-EN 772-20:2002+A1:2005","categories":["other"],"row_index":120,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Clay masonry units Flatness of the facing surfaces PN-EN 772-20:2002+A1:2005","search_zh":"烧结黏土砌块 PN-EN 772-20:2002+A1:2005","test_object_zh":"烧结黏土砌块"},{"_id":"6a5dc9bbf1c10c8ce825e045","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Elementy murowe ceramiczne","test_object_en":"Clay masonry units","methodology":"Absorpcja wody","methodology_en":"Water absorption","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Absorpcja wody","reference":"PN-EN 772-21:2011","norm_bases":["PN-EN 772-21:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy murowe ceramiczne Absorpcja wody PN-EN 772-21:2011 Elementy murowe ceramiczne Absorpcja wody PN-EN 772-21:2011","categories":["water"],"row_index":121,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Clay masonry units Water absorption PN-EN 772-21:2011","search_zh":"烧结黏土砌块 吸水率 PN-EN 772-21:2011","test_object_zh":"烧结黏土砌块","methodology_zh":"吸水率"},{"_id":"6a5dc9bbf1c10c8ce825e046","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Elementy murowe ceramiczne","test_object_en":"Clay masonry units","methodology":"Odporność na zamrażanie-odmrażanie","methodology_en":"Freeze-thaw resistance","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na zamrażanie-odmrażanie","reference":"PN-B-12012:2022-07 | PN-EN 772-22:2019-01","norm_bases":["PN-B-12012:2022-07","PN-EN 772-22:2019-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy murowe ceramiczne Odporność na zamrażanie-odmrażanie PN-B-12012:2022-07 | PN-EN 772-22:2019-01 Elementy murowe ceramiczne Odpornosc na zamrazanie-odmrazanie PN-B-12012:2022-07 | PN-EN 772-22:2019-01","categories":["other"],"row_index":122,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Clay masonry units Freeze-thaw resistance PN-B-12012:2022-07 | PN-EN 772-22:2019-01","search_zh":"烧结黏土砌块 PN-B-12012:2022-07 | PN-EN 772-22:2019-01","test_object_zh":"烧结黏土砌块"},{"_id":"6a5dc9bbf1c10c8ce825e047","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Pustaki ceramiczne wentylacyjne","test_object_en":"Ceramic ventilation blocks","methodology":"Wytrzymałość na ściskanie","methodology_en":"Compressive strength","parameters":[{"name":"Zakres siły","range":"(100 – 3000) kN"}],"parameters_en":[{"name":"Force range","range":"(100 – 3000) kN"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ściskanie\nZakres siły (100 – 3000) kN","reference":"PN-EN 772-1+A1:2015-10","norm_bases":["PN-EN 772-1+A1:2015-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pustaki ceramiczne wentylacyjne Wytrzymałość na ściskanie\nZakres siły (100 – 3000) kN PN-EN 772-1+A1:2015-10 Pustaki ceramiczne wentylacyjne Wytrzymalosc na sciskanie\nZakres sily (100 – 3000) kN PN-EN 772-1+A1:2015-10","categories":["other"],"row_index":123,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Ceramic ventilation blocks Compressive strength Force range PN-EN 772-1+A1:2015-10","methodology_zh":"抗压强度","parameters_zh":[{"name":"力值范围","range":"(100 – 3000) kN"}],"search_zh":"陶瓷通风空心砖 抗压强度 力值范围 PN-EN 772-1+A1:2015-10","test_object_zh":"陶瓷通风空心砖"},{"_id":"6a5dc9bbf1c10c8ce825e048","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Pustaki ceramiczne wentylacyjne","test_object_en":"Ceramic ventilation blocks","methodology":"Masa w stanie suchym, Gęstość netto w stanie suchym, Gęstość brutto w stanie suchym","methodology_en":"Dry mass, Net dry density, Gross dry density","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Masa w stanie suchym, Gęstość netto w stanie suchym, Gęstość brutto w stanie suchym","reference":"PN-EN 772-13:2001","norm_bases":["PN-EN 772-13:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pustaki ceramiczne wentylacyjne Masa w stanie suchym, Gęstość netto w stanie suchym, Gęstość brutto w stanie suchym PN-EN 772-13:2001 Pustaki ceramiczne wentylacyjne Masa w stanie suchym, Gestosc netto w stanie suchym, Gestosc brutto w stanie suchym PN-EN 772-13:2001","categories":["other"],"row_index":124,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Ceramic ventilation blocks Dry mass, Net dry density, Gross dry density PN-EN 772-13:2001","search_zh":"陶瓷通风空心砖 PN-EN 772-13:2001","test_object_zh":"陶瓷通风空心砖"},{"_id":"6a5dc9bbf1c10c8ce825e049","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Pustaki ceramiczne wentylacyjne","test_object_en":"Ceramic ventilation blocks","methodology":"Wymiary: długość, szerokość, wysokość, Kształt i budowa: grubość ścianek zewnętrznych, wewnętrznych, powierzchnia otworów wentylacyjnych","methodology_en":"Dimensions: length, width, height, Shape and configuration: thickness of external and internal walls, area of the ventilation openings","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wymiary: długość, szerokość, wysokość, Kształt i budowa: grubość ścianek zewnętrznych, wewnętrznych, powierzchnia otworów wentylacyjnych","reference":"PN-EN 772-16:2011 | PN-B-12014:2023-07","norm_bases":["PN-EN 772-16:2011","PN-B-12014:2023-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pustaki ceramiczne wentylacyjne Wymiary: długość, szerokość, wysokość, Kształt i budowa: grubość ścianek zewnętrznych, wewnętrznych, powierzchnia otworów wentylacyjnych PN-EN 772-16:2011 | PN-B-12014:2023-07 Pustaki ceramiczne wentylacyjne Wymiary: dlugosc, szerokosc, wysokosc, Ksztalt i budowa: grubosc scianek zewnetrznych, wewnetrznych, powierzchnia otworow wentylacyjnych PN-EN 772-16:2011 | PN-B-12014:2023-07","categories":["other"],"row_index":125,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Ceramic ventilation blocks Dimensions: length, width, height, Shape and configuration: thickness of external and internal walls, area of the ventilation openings PN-EN 772-16:2011 | PN-B-12014:2023-07","search_zh":"陶瓷通风空心砖 PN-EN 772-16:2011 | PN-B-12014:2023-07","test_object_zh":"陶瓷通风空心砖"},{"_id":"6a5dc9bbf1c10c8ce825e04a","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Pustaki ceramiczne wentylacyjne","test_object_en":"Ceramic ventilation blocks","methodology":"Absorpcja wody","methodology_en":"Water absorption","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Absorpcja wody","reference":"PN-EN 772-21:2011","norm_bases":["PN-EN 772-21:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pustaki ceramiczne wentylacyjne Absorpcja wody PN-EN 772-21:2011 Pustaki ceramiczne wentylacyjne Absorpcja wody PN-EN 772-21:2011","categories":["water"],"row_index":126,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Ceramic ventilation blocks Water absorption PN-EN 772-21:2011","methodology_zh":"吸水率","search_zh":"陶瓷通风空心砖 吸水率 PN-EN 772-21:2011","test_object_zh":"陶瓷通风空心砖"},{"_id":"6a5dc9bbf1c10c8ce825e04b","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Dachówki ceramiczne","test_object_en":"Clay roof tiles","methodology":"Nośność na zginanie","methodology_en":"Bending load capacity","parameters":[{"name":"Zakres siły","range":"(0,5 – 20,0) kN"}],"parameters_en":[{"name":"Force range","range":"(0,5 – 20,0) kN"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Nośność na zginanie\nZakres siły (0,5 – 20,0) kN","reference":"PN-EN 538:1999","norm_bases":["PN-EN 538:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Dachówki ceramiczne Nośność na zginanie\nZakres siły (0,5 – 20,0) kN PN-EN 538:1999 Dachowki ceramiczne Nosnosc na zginanie\nZakres sily (0,5 – 20,0) kN PN-EN 538:1999","categories":["construction"],"row_index":127,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Clay roof tiles Bending load capacity Force range PN-EN 538:1999","parameters_zh":[{"name":"力值范围","range":"(0,5 – 20,0) kN"}],"search_zh":"陶瓷屋面瓦 力值范围 PN-EN 538:1999","test_object_zh":"陶瓷屋面瓦"},{"_id":"6a5dc9bbf1c10c8ce825e04c","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Dachówki ceramiczne","test_object_en":"Clay roof tiles","methodology":"Przesiąkliwość","methodology_en":"Water penetration","parameters":[],"parameters_en":[],"technique":"Metoda 2","techniques":["Metoda 2"],"technique_en":"Method 2","computed":[],"computed_en":[],"activity":"Przesiąkliwość\nMetoda 2","reference":"PN-EN 539-1:2007","norm_bases":["PN-EN 539-1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Dachówki ceramiczne Przesiąkliwość\nMetoda 2 PN-EN 539-1:2007 Dachowki ceramiczne Przesiakliwosc\nMetoda 2 PN-EN 539-1:2007","categories":["construction"],"row_index":128,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Clay roof tiles Water penetration Method 2 PN-EN 539-1:2007","search_zh":"陶瓷屋面瓦 方法 2 PN-EN 539-1:2007","test_object_zh":"陶瓷屋面瓦","technique_zh":"方法 2"},{"_id":"6a5dc9bbf1c10c8ce825e04d","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Dachówki ceramiczne","test_object_en":"Clay roof tiles","methodology":"Mrozoodporność","methodology_en":"Frost resistance","parameters":[{"name":"Zakres","range":"(od -19 do +17) oC"}],"parameters_en":[{"name":"Range","range":"(od -19 do +17) oC"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Mrozoodporność\nZakres (od -19 do +17) oC","reference":"PN-EN 539-2:2013-07","norm_bases":["PN-EN 539-2:2013-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Dachówki ceramiczne Mrozoodporność\nZakres (od -19 do +17) oC PN-EN 539-2:2013-07 Dachowki ceramiczne Mrozoodpornosc\nZakres (od -19 do +17) oC PN-EN 539-2:2013-07","categories":["construction"],"row_index":129,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Clay roof tiles Frost resistance Range PN-EN 539-2:2013-07","parameters_zh":[{"name":"范围","range":"(od -19 do +17) oC"}],"search_zh":"陶瓷屋面瓦 抗冻性 范围 PN-EN 539-2:2013-07","methodology_zh":"抗冻性","test_object_zh":"陶瓷屋面瓦"},{"_id":"6a5dc9bbf1c10c8ce825e04e","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Dachówki ceramiczne","test_object_en":"Clay roof tiles","methodology":"Absorpcja wody","methodology_en":"Water absorption","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Absorpcja wody","reference":"PN-EN 539-2:2013-07","norm_bases":["PN-EN 539-2:2013-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Dachówki ceramiczne Absorpcja wody PN-EN 539-2:2013-07 Dachowki ceramiczne Absorpcja wody PN-EN 539-2:2013-07","categories":["water","construction"],"row_index":130,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Clay roof tiles Water absorption PN-EN 539-2:2013-07","methodology_zh":"吸水率","search_zh":"陶瓷屋面瓦 吸水率 PN-EN 539-2:2013-07","test_object_zh":"陶瓷屋面瓦"},{"_id":"6a5dc9bbf1c10c8ce825e04f","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Dachówki ceramiczne","test_object_en":"Clay roof tiles","methodology":"Wymiary geometryczne liniowe","methodology_en":"Linear geometric dimensions","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wymiary geometryczne liniowe","reference":"PN-EN 1024:2012","norm_bases":["PN-EN 1024:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Dachówki ceramiczne Wymiary geometryczne liniowe PN-EN 1024:2012 Dachowki ceramiczne Wymiary geometryczne liniowe PN-EN 1024:2012","categories":["construction"],"row_index":131,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Clay roof tiles Linear geometric dimensions PN-EN 1024:2012","methodology_zh":"几何线性尺寸","search_zh":"陶瓷屋面瓦 几何线性尺寸 PN-EN 1024:2012","test_object_zh":"陶瓷屋面瓦"},{"_id":"6a5dc9bbf1c10c8ce825e050","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Cementy, spoiwa mineralno- cementowe, popioły lotne, materiały wiążące","test_object_en":"Cements, mineral-cement binders, fly ashes, binding materials","methodology":"Wytrzymałość na ściskanie","methodology_en":"Compressive strength","parameters":[{"name":"Zakres","range":"(0,5 – 100) kN"},{"name":"Wytrzymałość na zginanie"},{"name":"Zakres","range":"(0,5 – 50) kN"}],"parameters_en":[{"name":"Range","range":"(0,5 – 100) kN"},{"name":"Flexural strength"},{"name":"Range","range":"(0,5 – 50) kN"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ściskanie\nZakres:\nZakres (0,5 – 100) kN\nWytrzymałość na zginanie\nZakres (0,5 – 50) kN","reference":"PN-EN 196-1:2016-07","norm_bases":["PN-EN 196-1:2016-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Cementy, spoiwa mineralno- cementowe, popioły lotne, materiały wiążące Wytrzymałość na ściskanie\nZakres:\nZakres (0,5 – 100) kN\nWytrzymałość na zginanie\nZakres (0,5 – 50) kN PN-EN 196-1:2016-07 Cementy, spoiwa mineralno- cementowe, popioly lotne, materialy wiazace Wytrzymalosc na sciskanie\nZakres:\nZakres (0,5 – 100) kN\nWytrzymalosc na zginanie\nZakres (0,5 – 50) kN PN-EN 196-1:2016-07","categories":["materials","construction"],"row_index":132,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cements, mineral-cement binders, fly ashes, binding materials Compressive strength Range Flexural strength Range PN-EN 196-1:2016-07","methodology_zh":"抗压强度","parameters_zh":[{"name":"范围","range":"(0,5 – 100) kN"},{"name":"抗弯强度"},{"name":"范围","range":"(0,5 – 50) kN"}],"search_zh":"抗压强度 范围 抗弯强度 范围 PN-EN 196-1:2016-07"},{"_id":"6a5dc9bbf1c10c8ce825e051","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Cementy, spoiwa mineralno- cementowe, popioły lotne, materiały wiążące","test_object_en":"Cements, mineral-cement binders, fly ashes, binding materials","methodology":"Czas wiązania","methodology_en":"Setting time","parameters":[{"name":"Vicata"}],"parameters_en":[{"name":"Vicat"}],"technique":"Metoda ręczna za pomocą aparatu; Metoda za pomocą automatycznego aparatu Vicata","techniques":["Metoda ręczna za pomocą aparatu","Metoda za pomocą automatycznego aparatu Vicata"],"technique_en":"Manual method using an apparatus; Method using an automatic Vicat apparatus","computed":[],"computed_en":[],"activity":"Czas wiązania\nVicata\nMetoda ręczna za pomocą aparatu; Metoda za pomocą automatycznego aparatu Vicata","reference":"PN-EN 196-3:2016-12 | PN-EN 450-1:2012","norm_bases":["PN-EN 196-3:2016-12","PN-EN 450-1:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Cementy, spoiwa mineralno- cementowe, popioły lotne, materiały wiążące Czas wiązania\nVicata\nMetoda ręczna za pomocą aparatu; Metoda za pomocą automatycznego aparatu Vicata PN-EN 196-3:2016-12 | PN-EN 450-1:2012 Cementy, spoiwa mineralno- cementowe, popioly lotne, materialy wiazace Czas wiazania\nVicata\nMetoda reczna za pomoca aparatu; Metoda za pomoca automatycznego aparatu Vicata PN-EN 196-3:2016-12 | PN-EN 450-1:2012","categories":["materials","construction"],"row_index":133,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cements, mineral-cement binders, fly ashes, binding materials Setting time Manual method using an apparatus; Method using an automatic Vicat apparatus Vicat PN-EN 196-3:2016-12 | PN-EN 450-1:2012","methodology_zh":"凝结时间","search_zh":"凝结时间 PN-EN 196-3:2016-12 | PN-EN 450-1:2012"},{"_id":"6a5dc9bbf1c10c8ce825e052","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Cementy, spoiwa mineralno- cementowe, popioły lotne, materiały wiążące","test_object_en":"Cements, mineral-cement binders, fly ashes, binding materials","methodology":"Stałość objętości","methodology_en":"Soundness","parameters":[{"name":"Zakres","range":"(0 – 5) mm"},{"name":"Le Chateliera"}],"parameters_en":[{"name":"Range","range":"(0 – 5) mm"},{"name":"Le Chatelier"}],"technique":"Metoda za pomocą pierścienia","techniques":["Metoda za pomocą pierścienia"],"technique_en":"Method using a ring","computed":[],"computed_en":[],"activity":"Stałość objętości\nZakres:\nZakres (0 – 5) mm\nLe Chateliera\nMetoda za pomocą pierścienia","reference":"PN-EN 196-3:2016-12 | PN-EN 450-1:2012","norm_bases":["PN-EN 196-3:2016-12","PN-EN 450-1:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Cementy, spoiwa mineralno- cementowe, popioły lotne, materiały wiążące Stałość objętości\nZakres:\nZakres (0 – 5) mm\nLe Chateliera\nMetoda za pomocą pierścienia PN-EN 196-3:2016-12 | PN-EN 450-1:2012 Cementy, spoiwa mineralno- cementowe, popioly lotne, materialy wiazace Stalosc objetosci\nZakres:\nZakres (0 – 5) mm\nLe Chateliera\nMetoda za pomoca pierscienia PN-EN 196-3:2016-12 | PN-EN 450-1:2012","categories":["materials","construction"],"row_index":134,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cements, mineral-cement binders, fly ashes, binding materials Soundness Method using a ring Range Le Chatelier PN-EN 196-3:2016-12 | PN-EN 450-1:2012","parameters_zh":[{"name":"范围","range":"(0 – 5) mm"},{"name":"勒沙特列"}],"search_zh":"体积安定性 范围 勒沙特列 PN-EN 196-3:2016-12 | PN-EN 450-1:2012","methodology_zh":"体积安定性"},{"_id":"6a5dc9bbf1c10c8ce825e053","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Cementy, spoiwa mineralno- cementowe, materiały wiążące","test_object_en":"Cements, mineral-cement binders, binding materials","methodology":"Konsystencja (wodożądność)","methodology_en":"Consistency (water demand)","parameters":[],"parameters_en":[],"technique":"Metoda za pomocą aparatu Vicata","techniques":["Metoda za pomocą aparatu Vicata"],"technique_en":"Method using the Vicat apparatus","computed":[],"computed_en":[],"activity":"Konsystencja (wodożądność)\nMetoda za pomocą aparatu Vicata","reference":"PN-EN 196-3:2016-12","norm_bases":["PN-EN 196-3:2016-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Cementy, spoiwa mineralno- cementowe, materiały wiążące Konsystencja (wodożądność)\nMetoda za pomocą aparatu Vicata PN-EN 196-3:2016-12 Cementy, spoiwa mineralno- cementowe, materialy wiazace Konsystencja (wodozadnosc)\nMetoda za pomoca aparatu Vicata PN-EN 196-3:2016-12","categories":["materials","construction"],"row_index":135,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cements, mineral-cement binders, binding materials Consistency (water demand) Method using the Vicat apparatus PN-EN 196-3:2016-12"},{"_id":"6a5dc9bbf1c10c8ce825e054","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Popioły lotne","test_object_en":"Fly ashes","methodology":"Konsystencja (wodożądność)","methodology_en":"Consistency (water demand)","parameters":[],"parameters_en":[],"technique":"Metoda za pomocą stolika rozpływu","techniques":["Metoda za pomocą stolika rozpływu"],"technique_en":"Method using a flow table","computed":[],"computed_en":[],"activity":"Konsystencja (wodożądność)\nMetoda za pomocą stolika rozpływu","reference":"PN-EN 450-1:2012","norm_bases":["PN-EN 450-1:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Popioły lotne Konsystencja (wodożądność)\nMetoda za pomocą stolika rozpływu PN-EN 450-1:2012 Popioly lotne Konsystencja (wodozadnosc)\nMetoda za pomoca stolika rozplywu PN-EN 450-1:2012","categories":["other"],"row_index":136,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Fly ashes Consistency (water demand) Method using a flow table PN-EN 450-1:2012","search_zh":"飞灰 PN-EN 450-1:2012","test_object_zh":"飞灰"},{"_id":"6a5dc9bbf1c10c8ce825e055","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Popioły lotne","test_object_en":"Fly ashes","methodology":"Wskaźnik aktywności (z obliczeń)","methodology_en":"Activity index (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik aktywności (z obliczeń)","reference":"PN-EN 450-1:2012","norm_bases":["PN-EN 450-1:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Popioły lotne Wskaźnik aktywności (z obliczeń) PN-EN 450-1:2012 Popioly lotne Wskaznik aktywnosci (z obliczen) PN-EN 450-1:2012","categories":["other"],"row_index":137,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Fly ashes Activity index (calculated) PN-EN 450-1:2012","methodology_zh":"活性指数（由计算得出）","search_zh":"飞灰 活性指数（由计算得出） PN-EN 450-1:2012","test_object_zh":"飞灰"},{"_id":"6a5dc9bbf1c10c8ce825e056","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Żużle wielkopiecowe","test_object_en":"Blast furnace slags","methodology":"Czas wiązania","methodology_en":"Setting time","parameters":[{"name":"Vicata"}],"parameters_en":[{"name":"Vicat"}],"technique":"Metoda ręczna za pomocą aparatu; Metoda za pomocą automatycznego aparatu Vicata","techniques":["Metoda ręczna za pomocą aparatu","Metoda za pomocą automatycznego aparatu Vicata"],"technique_en":"Manual method using an apparatus; Method using an automatic Vicat apparatus","computed":[],"computed_en":[],"activity":"Czas wiązania\nVicata\nMetoda ręczna za pomocą aparatu; Metoda za pomocą automatycznego aparatu Vicata","reference":"PN-EN 15167-1:2007 | PN-EN 196-3:2016-12","norm_bases":["PN-EN 15167-1:2007","PN-EN 196-3:2016-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Żużle wielkopiecowe Czas wiązania\nVicata\nMetoda ręczna za pomocą aparatu; Metoda za pomocą automatycznego aparatu Vicata PN-EN 15167-1:2007 | PN-EN 196-3:2016-12 Zuzle wielkopiecowe Czas wiazania\nVicata\nMetoda reczna za pomoca aparatu; Metoda za pomoca automatycznego aparatu Vicata PN-EN 15167-1:2007 | PN-EN 196-3:2016-12","categories":["other"],"row_index":138,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Blast furnace slags Setting time Manual method using an apparatus; Method using an automatic Vicat apparatus Vicat PN-EN 15167-1:2007 | PN-EN 196-3:2016-12","methodology_zh":"凝结时间","search_zh":"凝结时间 PN-EN 15167-1:2007 | PN-EN 196-3:2016-12"},{"_id":"6a5dc9bbf1c10c8ce825e057","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Kruszywa","test_object_en":"Aggregates","methodology":"Skład ziarnowy","methodology_en":"Particle size distribution","parameters":[{"name":"Zakres","range":"(0,063 – 90,0) mm"}],"parameters_en":[{"name":"Range","range":"(0,063 – 90,0) mm"}],"technique":"Metoda przesiewania","techniques":["Metoda przesiewania"],"technique_en":"Sieving method","computed":[],"computed_en":[],"activity":"Skład ziarnowy\nZakres (0,063 – 90,0) mm\nMetoda przesiewania","reference":"PN-EN 933-1:2012","norm_bases":["PN-EN 933-1:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywa Skład ziarnowy\nZakres (0,063 – 90,0) mm\nMetoda przesiewania PN-EN 933-1:2012 Kruszywa Sklad ziarnowy\nZakres (0,063 – 90,0) mm\nMetoda przesiewania PN-EN 933-1:2012","categories":["other"],"row_index":139,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Aggregates Particle size distribution Sieving method Range PN-EN 933-1:2012","parameters_zh":[{"name":"范围","range":"(0,063 – 90,0) mm"}],"search_zh":"骨料 粒度分布 筛分法 范围 PN-EN 933-1:2012","test_object_zh":"骨料","methodology_zh":"粒度分布","technique_zh":"筛分法"},{"_id":"6a5dc9bbf1c10c8ce825e058","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Kruszywa","test_object_en":"Aggregates","methodology":"Zawartość pyłów <0,063 mm","methodology_en":"Fines content <0,063 mm","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość pyłów <0,063 mm","reference":"PN-EN 933-1:2012","norm_bases":["PN-EN 933-1:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywa Zawartość pyłów <0,063 mm PN-EN 933-1:2012 Kruszywa Zawartosc pylow <0,063 mm PN-EN 933-1:2012","categories":["other"],"row_index":140,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Aggregates Fines content <0,063 mm PN-EN 933-1:2012","search_zh":"骨料 PN-EN 933-1:2012","test_object_zh":"骨料"},{"_id":"6a5dc9bbf1c10c8ce825e059","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Kruszywa","test_object_en":"Aggregates","methodology":"Zawartość ziaren drobnych <0,5 mm","methodology_en":"Content of fine grains <0,5 mm","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość ziaren drobnych <0,5 mm","reference":"PN-EN 933-1:2012","norm_bases":["PN-EN 933-1:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywa Zawartość ziaren drobnych <0,5 mm PN-EN 933-1:2012 Kruszywa Zawartosc ziaren drobnych <0,5 mm PN-EN 933-1:2012","categories":["other"],"row_index":141,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Aggregates Content of fine grains <0,5 mm PN-EN 933-1:2012","search_zh":"骨料 PN-EN 933-1:2012","test_object_zh":"骨料"},{"_id":"6a5dc9bbf1c10c8ce825e05a","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Kruszywa","test_object_en":"Aggregates","methodology":"Wskaźnik płaskości","methodology_en":"Flakiness index","parameters":[{"name":"Zakres","range":"(4 – 100) mm"}],"parameters_en":[{"name":"Range","range":"(4 – 100) mm"}],"technique":"Metoda przesiewania","techniques":["Metoda przesiewania"],"technique_en":"Sieving method","computed":[],"computed_en":[],"activity":"Wskaźnik płaskości\nZakres (4 – 100) mm\nMetoda przesiewania","reference":"PN-EN 933-3:2012 WTWiOPK Id-110:2024","norm_bases":["PN-EN 933-3:2012 WTWiOPK Id-110:2024"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywa Wskaźnik płaskości\nZakres (4 – 100) mm\nMetoda przesiewania PN-EN 933-3:2012 WTWiOPK Id-110:2024 Kruszywa Wskaznik plaskosci\nZakres (4 – 100) mm\nMetoda przesiewania PN-EN 933-3:2012 WTWiOPK Id-110:2024","categories":["other"],"row_index":142,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Aggregates Flakiness index Sieving method Range PN-EN 933-3:2012 WTWiOPK Id-110:2024","parameters_zh":[{"name":"范围","range":"(4 – 100) mm"}],"search_zh":"骨料 片状指数 筛分法 范围 PN-EN 933-3:2012 WTWiOPK Id-110:2024","test_object_zh":"骨料","technique_zh":"筛分法","methodology_zh":"片状指数"},{"_id":"6a5dc9bbf1c10c8ce825e05b","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Kruszywa","test_object_en":"Aggregates","methodology":"Wskaźnik kształtu","methodology_en":"Shape index","parameters":[],"parameters_en":[],"technique":"Metoda za pomocą suwmiarki Schultza","techniques":["Metoda za pomocą suwmiarki Schultza"],"technique_en":"Method using the Schultz calliper","computed":[],"computed_en":[],"activity":"Wskaźnik kształtu\nMetoda za pomocą suwmiarki Schultza","reference":"PN-EN 933-4:2008","norm_bases":["PN-EN 933-4:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywa Wskaźnik kształtu\nMetoda za pomocą suwmiarki Schultza PN-EN 933-4:2008 Kruszywa Wskaznik ksztaltu\nMetoda za pomoca suwmiarki Schultza PN-EN 933-4:2008","categories":["other"],"row_index":143,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Aggregates Shape index Method using the Schultz calliper PN-EN 933-4:2008","search_zh":"骨料 形状指数 PN-EN 933-4:2008","test_object_zh":"骨料","methodology_zh":"形状指数"},{"_id":"6a5dc9bbf1c10c8ce825e05c","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Kruszywa","test_object_en":"Aggregates","methodology":"Zawartość ziarn przekruszonych","methodology_en":"Content of crushed particles","parameters":[{"name":"Zakres","range":"(4 – 63) mm"}],"parameters_en":[{"name":"Range","range":"(4 – 63) mm"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość ziarn przekruszonych\nZakres (4 – 63) mm\nMetoda wagowa","reference":"PN-EN 933-5:2023-05","norm_bases":["PN-EN 933-5:2023-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywa Zawartość ziarn przekruszonych\nZakres (4 – 63) mm\nMetoda wagowa PN-EN 933-5:2023-05 Kruszywa Zawartosc ziarn przekruszonych\nZakres (4 – 63) mm\nMetoda wagowa PN-EN 933-5:2023-05","categories":["other"],"row_index":144,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Aggregates Content of crushed particles Gravimetric method Range PN-EN 933-5:2023-05","parameters_zh":[{"name":"范围","range":"(4 – 63) mm"}],"search_zh":"骨料 压碎颗粒含量 重量法 范围 PN-EN 933-5:2023-05","technique_zh":"重量法","test_object_zh":"骨料","methodology_zh":"压碎颗粒含量"},{"_id":"6a5dc9bbf1c10c8ce825e05d","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Kruszywa","test_object_en":"Aggregates","methodology":"Wskaźnik przepływu kruszyw","methodology_en":"Flow coefficient of aggregates","parameters":[{"name":"Zakres","range":"(0 – 2) mm"}],"parameters_en":[{"name":"Range","range":"(0 – 2) mm"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik przepływu kruszyw\nZakres (0 – 2) mm","reference":"PN-EN 933-6:2023-06","norm_bases":["PN-EN 933-6:2023-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywa Wskaźnik przepływu kruszyw\nZakres (0 – 2) mm PN-EN 933-6:2023-06 Kruszywa Wskaznik przeplywu kruszyw\nZakres (0 – 2) mm PN-EN 933-6:2023-06","categories":["other"],"row_index":145,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Aggregates Flow coefficient of aggregates Range PN-EN 933-6:2023-06","parameters_zh":[{"name":"范围","range":"(0 – 2) mm"}],"search_zh":"骨料 范围 PN-EN 933-6:2023-06","test_object_zh":"骨料"},{"_id":"6a5dc9bbf1c10c8ce825e05e","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Kruszywa","test_object_en":"Aggregates","methodology":"Wskaźnik piaskowy","methodology_en":"Sand equivalent value","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik piaskowy","reference":"PN-EN 933-8+A1:2015-07","norm_bases":["PN-EN 933-8+A1:2015-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywa Wskaźnik piaskowy PN-EN 933-8+A1:2015-07 Kruszywa Wskaznik piaskowy PN-EN 933-8+A1:2015-07","categories":["other"],"row_index":146,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Aggregates Sand equivalent value PN-EN 933-8+A1:2015-07","search_zh":"骨料 砂当量 PN-EN 933-8+A1:2015-07","test_object_zh":"骨料","methodology_zh":"砂当量"},{"_id":"6a5dc9bbf1c10c8ce825e05f","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Kruszywa","test_object_en":"Aggregates","methodology":"Odporność na ścieranie","methodology_en":"Abrasion resistance","parameters":[],"parameters_en":[],"technique":"Metoda mikro-Deval","techniques":["Metoda mikro-Deval"],"technique_en":"Micro-Deval method","computed":[],"computed_en":[],"activity":"Odporność na ścieranie\nMetoda mikro-Deval","reference":"PN-EN 1097-1:2024-05","norm_bases":["PN-EN 1097-1:2024-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywa Odporność na ścieranie\nMetoda mikro-Deval PN-EN 1097-1:2024-05 Kruszywa Odpornosc na scieranie\nMetoda mikro-Deval PN-EN 1097-1:2024-05","categories":["other"],"row_index":147,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Aggregates Abrasion resistance Micro-Deval method PN-EN 1097-1:2024-05","search_zh":"骨料 耐磨性 微 Deval 法 PN-EN 1097-1:2024-05","test_object_zh":"骨料","methodology_zh":"耐磨性","technique_zh":"微 Deval 法"},{"_id":"6a5dc9bbf1c10c8ce825e060","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Kruszywa","test_object_en":"Aggregates","methodology":"Odporność na rozdrabnianie","methodology_en":"Resistance to fragmentation","parameters":[],"parameters_en":[],"technique":"Metoda Los Angeles","techniques":["Metoda Los Angeles"],"technique_en":"Los Angeles method","computed":[],"computed_en":[],"activity":"Odporność na rozdrabnianie\nMetoda Los Angeles","reference":"PN-EN 1097-2:2020-09","norm_bases":["PN-EN 1097-2:2020-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywa Odporność na rozdrabnianie\nMetoda Los Angeles PN-EN 1097-2:2020-09 Kruszywa Odpornosc na rozdrabnianie\nMetoda Los Angeles PN-EN 1097-2:2020-09","categories":["other"],"row_index":148,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Aggregates Resistance to fragmentation Los Angeles method PN-EN 1097-2:2020-09","search_zh":"骨料 抗破碎性 洛杉矶法 PN-EN 1097-2:2020-09","test_object_zh":"骨料","methodology_zh":"抗破碎性","technique_zh":"洛杉矶法"},{"_id":"6a5dc9bbf1c10c8ce825e061","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Kruszywa","test_object_en":"Aggregates","methodology":"Gęstość nasypowa i jamistość","methodology_en":"Bulk density and voids","parameters":[{"name":"Zakres","range":"(0 – 63) mm"}],"parameters_en":[{"name":"Range","range":"(0 – 63) mm"}],"technique":"Metoda wagowo-objętościowa","techniques":["Metoda wagowo-objętościowa"],"technique_en":"Gravimetric-volumetric method","computed":[],"computed_en":[],"activity":"Gęstość nasypowa i jamistość\nZakres (0 – 63) mm\nMetoda wagowo-objętościowa","reference":"PN-EN 1097-3:2000","norm_bases":["PN-EN 1097-3:2000"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywa Gęstość nasypowa i jamistość\nZakres (0 – 63) mm\nMetoda wagowo-objętościowa PN-EN 1097-3:2000 Kruszywa Gestosc nasypowa i jamistosc\nZakres (0 – 63) mm\nMetoda wagowo-objetosciowa PN-EN 1097-3:2000","categories":["other"],"row_index":149,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Aggregates Bulk density and voids Gravimetric-volumetric method Range PN-EN 1097-3:2000","parameters_zh":[{"name":"范围","range":"(0 – 63) mm"}],"search_zh":"骨料 堆积密度与空隙率 重量-容量法 范围 PN-EN 1097-3:2000","technique_zh":"重量-容量法","test_object_zh":"骨料","methodology_zh":"堆积密度与空隙率"},{"_id":"6a5dc9bbf1c10c8ce825e062","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Kruszywa","test_object_en":"Aggregates","methodology":"Zawartość wody","methodology_en":"Water content","parameters":[{"name":"Zakres","range":"(0,1 – 13,0) %"}],"parameters_en":[{"name":"Range","range":"(0,1 – 13,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość wody\nZakres (0,1 – 13,0) %\nMetoda wagowa","reference":"PN-EN 1097-5:2008","norm_bases":["PN-EN 1097-5:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywa Zawartość wody\nZakres (0,1 – 13,0) %\nMetoda wagowa PN-EN 1097-5:2008 Kruszywa Zawartosc wody\nZakres (0,1 – 13,0) %\nMetoda wagowa PN-EN 1097-5:2008","categories":["water"],"row_index":150,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Aggregates Water content Gravimetric method Range PN-EN 1097-5:2008","methodology_zh":"水分含量","parameters_zh":[{"name":"范围","range":"(0,1 – 13,0) %"}],"search_zh":"骨料 水分含量 重量法 范围 PN-EN 1097-5:2008","technique_zh":"重量法","test_object_zh":"骨料"},{"_id":"6a5dc9bbf1c10c8ce825e063","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Kruszywa","test_object_en":"Aggregates","methodology":"Gęstość ziaren i nasiąkliwość","methodology_en":"Particle density and water absorption","parameters":[{"name":"Zakres","range":"(31,5 – 63,0) mm"}],"parameters_en":[{"name":"Range","range":"(31,5 – 63,0) mm"}],"technique":"Metoda drucianego kosza","techniques":["Metoda drucianego kosza"],"technique_en":"Wire basket method","computed":[],"computed_en":[],"activity":"Gęstość ziaren i nasiąkliwość\nZakres (31,5 – 63,0) mm\nMetoda drucianego kosza","reference":"PN-EN 1097-6:2022-07","norm_bases":["PN-EN 1097-6:2022-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywa Gęstość ziaren i nasiąkliwość\nZakres (31,5 – 63,0) mm\nMetoda drucianego kosza PN-EN 1097-6:2022-07 Kruszywa Gestosc ziaren i nasiakliwosc\nZakres (31,5 – 63,0) mm\nMetoda drucianego kosza PN-EN 1097-6:2022-07","categories":["other"],"row_index":151,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Aggregates Particle density and water absorption Wire basket method Range PN-EN 1097-6:2022-07","parameters_zh":[{"name":"范围","range":"(31,5 – 63,0) mm"}],"search_zh":"骨料 颗粒密度与吸水率 金属丝笼法 范围 PN-EN 1097-6:2022-07","test_object_zh":"骨料","methodology_zh":"颗粒密度与吸水率","technique_zh":"金属丝笼法"},{"_id":"6a5dc9bbf1c10c8ce825e064","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Kruszywa","test_object_en":"Aggregates","methodology":"Mrozoodporność w wodzie","methodology_en":"Frost resistance in water","parameters":[{"name":"Zakres","range":"(od -17,5 do +20) oC"}],"parameters_en":[{"name":"Range","range":"(od -17,5 do +20) oC"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Mrozoodporność w wodzie\nZakres (od -17,5 do +20) oC","reference":"PN-EN 1367-1:2007 | PN-EN 13450:2004+AC:2004","norm_bases":["PN-EN 1367-1:2007","PN-EN 13450:2004+AC:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywa Mrozoodporność w wodzie\nZakres (od -17,5 do +20) oC PN-EN 1367-1:2007 | PN-EN 13450:2004+AC:2004 Kruszywa Mrozoodpornosc w wodzie\nZakres (od -17,5 do +20) oC PN-EN 1367-1:2007 | PN-EN 13450:2004+AC:2004","categories":["other"],"row_index":152,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Aggregates Frost resistance in water Range PN-EN 1367-1:2007 | PN-EN 13450:2004+AC:2004","parameters_zh":[{"name":"范围","range":"(od -17,5 do +20) oC"}],"search_zh":"骨料 水中抗冻性 范围 PN-EN 1367-1:2007 | PN-EN 13450:2004+AC:2004","test_object_zh":"骨料","methodology_zh":"水中抗冻性"},{"_id":"6a5dc9bbf1c10c8ce825e065","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Kruszywa","test_object_en":"Aggregates","methodology":"Odporność na szok termiczny","methodology_en":"Resistance to thermal shock","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na szok termiczny","reference":"PN-EN 1367-5:2011","norm_bases":["PN-EN 1367-5:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywa Odporność na szok termiczny PN-EN 1367-5:2011 Kruszywa Odpornosc na szok termiczny PN-EN 1367-5:2011","categories":["other"],"row_index":153,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Aggregates Resistance to thermal shock PN-EN 1367-5:2011","search_zh":"骨料 耐热震性 PN-EN 1367-5:2011","test_object_zh":"骨料","methodology_zh":"耐热震性"},{"_id":"6a5dc9bbf1c10c8ce825e066","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Kruszywa","test_object_en":"Aggregates","methodology":"Mrozoodporność w soli","methodology_en":"Freeze-thaw resistance in salt","parameters":[{"name":"Zakres","range":"(od -17,5 do +20) oC"}],"parameters_en":[{"name":"Range","range":"(od -17,5 do +20) oC"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Mrozoodporność w soli\nZakres (od -17,5 do +20) oC","reference":"PN-EN 1367-6:2008","norm_bases":["PN-EN 1367-6:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywa Mrozoodporność w soli\nZakres (od -17,5 do +20) oC PN-EN 1367-6:2008 Kruszywa Mrozoodpornosc w soli\nZakres (od -17,5 do +20) oC PN-EN 1367-6:2008","categories":["other"],"row_index":154,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Aggregates Freeze-thaw resistance in salt Range PN-EN 1367-6:2008","parameters_zh":[{"name":"范围","range":"(od -17,5 do +20) oC"}],"search_zh":"骨料 盐冻抗冻性 范围 PN-EN 1367-6:2008","test_object_zh":"骨料","methodology_zh":"盐冻抗冻性"},{"_id":"6a5dc9bbf1c10c8ce825e067","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Kruszywa","test_object_en":"Aggregates","methodology":"Długość ziarna","methodology_en":"Grain length","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Długość ziarna","reference":"PN-EN 13450:2004+AC:2004","norm_bases":["PN-EN 13450:2004+AC:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywa Długość ziarna PN-EN 13450:2004+AC:2004 Kruszywa Dlugosc ziarna PN-EN 13450:2004+AC:2004","categories":["other"],"row_index":155,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Aggregates Grain length PN-EN 13450:2004+AC:2004","search_zh":"骨料 颗粒长度 PN-EN 13450:2004+AC:2004","test_object_zh":"骨料","methodology_zh":"颗粒长度"},{"_id":"6a5dc9bbf1c10c8ce825e068","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Kruszywa","test_object_en":"Aggregates","methodology":"Uproszczony opis petrograficzny","methodology_en":"Simplified petrographic description","parameters":[],"parameters_en":[],"technique":"Metoda: ocena makroskopowa","techniques":["Metoda: ocena makroskopowa"],"technique_en":"Method: macroscopic assessment","computed":[],"computed_en":[],"activity":"Uproszczony opis petrograficzny\nMetoda: ocena makroskopowa","reference":"PN-EN 932-3:2022-12","norm_bases":["PN-EN 932-3:2022-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywa Uproszczony opis petrograficzny\nMetoda: ocena makroskopowa PN-EN 932-3:2022-12 Kruszywa Uproszczony opis petrograficzny\nMetoda: ocena makroskopowa PN-EN 932-3:2022-12","categories":["petro"],"row_index":156,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Aggregates Simplified petrographic description Method: macroscopic assessment PN-EN 932-3:2022-12","search_zh":"骨料 简化岩相描述 PN-EN 932-3:2022-12","test_object_zh":"骨料","methodology_zh":"简化岩相描述"},{"_id":"6a5dc9bbf1c10c8ce825e069","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Kruszywa","test_object_en":"Aggregates","methodology":"Reaktywność alkaliczna","methodology_en":"Alkali reactivity","parameters":[],"parameters_en":[],"technique":"Metoda beleczkowa przyspieszona","techniques":["Metoda beleczkowa przyspieszona"],"technique_en":"Accelerated bar method","computed":[],"computed_en":[],"activity":"Reaktywność alkaliczna\nMetoda beleczkowa przyspieszona","reference":"Procedura Badawcza GDDKiA PB/1/18","norm_bases":["Procedura Badawcza GDDKiA PB/1/18"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywa Reaktywność alkaliczna\nMetoda beleczkowa przyspieszona Procedura Badawcza GDDKiA PB/1/18 Kruszywa Reaktywnosc alkaliczna\nMetoda beleczkowa przyspieszona Procedura Badawcza GDDKiA PB/1/18","categories":["other"],"row_index":157,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Aggregates Alkali reactivity Accelerated bar method Procedura Badawcza GDDKiA PB/1/18","search_zh":"骨料 碱活性 加速小梁法 Procedura Badawcza GDDKiA PB/1/18","test_object_zh":"骨料","methodology_zh":"碱活性","technique_zh":"加速小梁法"},{"_id":"6a5dc9bbf1c10c8ce825e06a","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Kruszywa","test_object_en":"Aggregates","methodology":"Reaktywność alkaliczna","methodology_en":"Alkali reactivity","parameters":[],"parameters_en":[],"technique":"Metoda beleczkowa długoterminowa","techniques":["Metoda beleczkowa długoterminowa"],"technique_en":"Long-term bar method","computed":[],"computed_en":[],"activity":"Reaktywność alkaliczna\nMetoda beleczkowa długoterminowa","reference":"Procedura Badawcza GDDKiA PB/2/18","norm_bases":["Procedura Badawcza GDDKiA PB/2/18"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywa Reaktywność alkaliczna\nMetoda beleczkowa długoterminowa Procedura Badawcza GDDKiA PB/2/18 Kruszywa Reaktywnosc alkaliczna\nMetoda beleczkowa dlugoterminowa Procedura Badawcza GDDKiA PB/2/18","categories":["other"],"row_index":158,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Aggregates Alkali reactivity Long-term bar method Procedura Badawcza GDDKiA PB/2/18","search_zh":"骨料 碱活性 Procedura Badawcza GDDKiA PB/2/18","test_object_zh":"骨料","methodology_zh":"碱活性"},{"_id":"6a5dc9bbf1c10c8ce825e06b","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Kruszywa","test_object_en":"Aggregates","methodology":"Zanieczyszczenia – obce i stałe","methodology_en":"Impurities – foreign and solid","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Zanieczyszczenia – obce i stałe","reference":"PN-B-06714/12:1976 WTWiOPK Id-110:2024","norm_bases":["PN-B-06714/12:1976 WTWiOPK Id-110:2024"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywa Zanieczyszczenia – obce i stałe PN-B-06714/12:1976 WTWiOPK Id-110:2024 Kruszywa Zanieczyszczenia – obce i stale PN-B-06714/12:1976 WTWiOPK Id-110:2024","categories":["other"],"row_index":159,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Aggregates Impurities – foreign and solid PN-B-06714/12:1976 WTWiOPK Id-110:2024","search_zh":"骨料 PN-B-06714/12:1976 WTWiOPK Id-110:2024","test_object_zh":"骨料"},{"_id":"6a5dc9bbf1c10c8ce825e06c","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Kruszywa wypełniające","test_object_en":"Filler aggregates","methodology":"Puste przestrzenie suchego zagęszczonego wypełniacza","methodology_en":"Voids in dry compacted filler","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Puste przestrzenie suchego zagęszczonego wypełniacza","reference":"PN-EN 1097-4:2008","norm_bases":["PN-EN 1097-4:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywa wypełniające Puste przestrzenie suchego zagęszczonego wypełniacza PN-EN 1097-4:2008 Kruszywa wypelniajace Puste przestrzenie suchego zageszczonego wypelniacza PN-EN 1097-4:2008","categories":["other"],"row_index":160,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Filler aggregates Voids in dry compacted filler PN-EN 1097-4:2008"},{"_id":"6a5dc9bbf1c10c8ce825e06d","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Kruszywa wypełniające","test_object_en":"Filler aggregates","methodology":"Liczba bitumiczna","methodology_en":"Bitumen number","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba bitumiczna","reference":"PN-EN 13179-2:2002","norm_bases":["PN-EN 13179-2:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywa wypełniające Liczba bitumiczna PN-EN 13179-2:2002 Kruszywa wypelniajace Liczba bitumiczna PN-EN 13179-2:2002","categories":["other"],"row_index":161,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Filler aggregates Bitumen number PN-EN 13179-2:2002","methodology_zh":"沥青值","search_zh":"沥青值 PN-EN 13179-2:2002"},{"_id":"6a5dc9bbf1c10c8ce825e06e","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Kruszywa i grunty","test_object_en":"Aggregates and soils","methodology":"Wilgotność optymalna","methodology_en":"Optimum moisture content","parameters":[{"name":"Zakres","range":"(1,0 – 40,0) %"},{"name":"Maksymalna gęstość szkieletu gruntowego"},{"name":"Zakres","range":"(1,00 – 3,00) g/cm3"}],"parameters_en":[{"name":"Range","range":"(1,0 – 40,0) %"},{"name":"Maximum density of the soil skeleton"},{"name":"Range","range":"(1,00 – 3,00) g/cm3"}],"technique":"Metoda Proctora","techniques":["Metoda Proctora"],"technique_en":"Proctor method","computed":[],"computed_en":[],"activity":"Wilgotność optymalna\nZakres:\nZakres (1,0 – 40,0) %\nMaksymalna gęstość szkieletu gruntowego\nZakres (1,00 – 3,00) g/cm3\nMetoda Proctora","reference":"PN-88/B-04481 | PN-EN 13286-2:2010 | PN-EN 13286-2:2010/AC:2014-07","norm_bases":["PN-88/B-04481","PN-EN 13286-2:2010","PN-EN 13286-2:2010/AC:2014-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywa i grunty Wilgotność optymalna\nZakres:\nZakres (1,0 – 40,0) %\nMaksymalna gęstość szkieletu gruntowego\nZakres (1,00 – 3,00) g/cm3\nMetoda Proctora PN-88/B-04481 | PN-EN 13286-2:2010 | PN-EN 13286-2:2010/AC:2014-07 Kruszywa i grunty Wilgotnosc optymalna\nZakres:\nZakres (1,0 – 40,0) %\nMaksymalna gestosc szkieletu gruntowego\nZakres (1,00 – 3,00) g/cm3\nMetoda Proctora PN-88/B-04481 | PN-EN 13286-2:2010 | PN-EN 13286-2:2010/AC:2014-07","categories":["other"],"row_index":162,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Aggregates and soils Optimum moisture content Proctor method Range Maximum density of the soil skeleton Range PN-88/B-04481 | PN-EN 13286-2:2010 | PN-EN 13286-2:2010/AC:2014-07","parameters_zh":[{"name":"范围","range":"(1,0 – 40,0) %"},{"name":"Maksymalna gęstość szkieletu gruntowego"},{"name":"范围","range":"(1,00 – 3,00) g/cm3"}],"search_zh":"最佳含水率 普氏击实法 范围 范围 PN-88/B-04481 | PN-EN 13286-2:2010 | PN-EN 13286-2:2010/AC:2014-07","technique_zh":"普氏击实法","methodology_zh":"最佳含水率"},{"_id":"6a5dc9bbf1c10c8ce825e06f","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Mieszanki niezwiązane i związane spoiwem hydraulicznym, Grunty, kruszywa","test_object_en":"Unbound and hydraulically bound mixtures, Soils, aggregates","methodology":"Pęcznienie liniowe","methodology_en":"Linear swelling","parameters":[{"name":"Zakres","range":"(0 – 5) mm"}],"parameters_en":[{"name":"Range","range":"(0 – 5) mm"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pęcznienie liniowe\nZakres (0 – 5) mm","reference":"PN-EN 13286-47:2022-04 | PN-S-06102:1997 Załącznik A | PN-S-02205:1998 Załącznik A","norm_bases":["PN-EN 13286-47:2022-04","PN-S-06102:1997 Załącznik A","PN-S-02205:1998 Załącznik A"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mieszanki niezwiązane i związane spoiwem hydraulicznym, Grunty, kruszywa Pęcznienie liniowe\nZakres (0 – 5) mm PN-EN 13286-47:2022-04 | PN-S-06102:1997 Załącznik A | PN-S-02205:1998 Załącznik A Mieszanki niezwiazane i zwiazane spoiwem hydraulicznym, Grunty, kruszywa Pecznienie liniowe\nZakres (0 – 5) mm PN-EN 13286-47:2022-04 | PN-S-06102:1997 Zalacznik A | PN-S-02205:1998 Zalacznik A","categories":["other"],"row_index":163,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Unbound and hydraulically bound mixtures, Soils, aggregates Linear swelling Range PN-EN 13286-47:2022-04 | PN-S-06102:1997 Załącznik A | PN-S-02205:1998 Załącznik A","parameters_zh":[{"name":"范围","range":"(0 – 5) mm"}],"search_zh":"线性膨胀 范围 PN-EN 13286-47:2022-04 | PN-S-06102:1997 Załącznik A | PN-S-02205:1998 Załącznik A","methodology_zh":"线性膨胀"},{"_id":"6a5dc9bbf1c10c8ce825e070","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Mieszanki niezwiązane i związane spoiwem hydraulicznym, Grunty, kruszywa","test_object_en":"Unbound and hydraulically bound mixtures, Soils, aggregates","methodology":"Wskaźnik nośności","methodology_en":"Bearing ratio","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik nośności","reference":"PN-EN 13286-47:2022-04 | PN-S-06102:1997 Załącznik A | PN-S-02205:1998 Załącznik A","norm_bases":["PN-EN 13286-47:2022-04","PN-S-06102:1997 Załącznik A","PN-S-02205:1998 Załącznik A"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mieszanki niezwiązane i związane spoiwem hydraulicznym, Grunty, kruszywa Wskaźnik nośności PN-EN 13286-47:2022-04 | PN-S-06102:1997 Załącznik A | PN-S-02205:1998 Załącznik A Mieszanki niezwiazane i zwiazane spoiwem hydraulicznym, Grunty, kruszywa Wskaznik nosnosci PN-EN 13286-47:2022-04 | PN-S-06102:1997 Zalacznik A | PN-S-02205:1998 Zalacznik A","categories":["other"],"row_index":164,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Unbound and hydraulically bound mixtures, Soils, aggregates Bearing ratio PN-EN 13286-47:2022-04 | PN-S-06102:1997 Załącznik A | PN-S-02205:1998 Załącznik A","methodology_zh":"承载比","search_zh":"承载比 PN-EN 13286-47:2022-04 | PN-S-06102:1997 Załącznik A | PN-S-02205:1998 Załącznik A"},{"_id":"6a5dc9bbf1c10c8ce825e071","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Surowce, materiały budowlane, Odpady: kod 10 01 01, 10 01 02, 03 01 05, 03 03 05, 10 01 03, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 81, 10 01 82","test_object_en":"Raw materials, building materials, Waste: code 10 01 01, 10 01 02, 03 01 05, 03 03 05, 10 01 03, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 81, 10 01 82","methodology":"","methodology_en":null,"parameters":[{"name":"Stężenie aktywności radionuklidu","range":"40K"},{"name":"Zakres","range":"(60 – 9 000) Bq/kg"}],"parameters_en":[{"name":"Radionuclide activity concentration","range":"40K"},{"name":"Range","range":"(60 – 9 000) Bq/kg"}],"technique":"Metoda spektrometrii promieniowania gamma","techniques":["Metoda spektrometrii promieniowania gamma"],"technique_en":"Gamma-ray spectrometry method","computed":[],"computed_en":[],"activity":"\nZakres:\nStężenie aktywności radionuklidu 40K\nZakres (60 – 9 000) Bq/kg\nMetoda spektrometrii promieniowania gamma","reference":"PB 33 wydanie 2 z dnia 22.04.2024 r.","norm_bases":["PB 33 wydanie 2 z dnia 22.04.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Surowce, materiały budowlane, Odpady: kod 10 01 01, 10 01 02, 03 01 05, 03 03 05, 10 01 03, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 81, 10 01 82 \nZakres:\nStężenie aktywności radionuklidu 40K\nZakres (60 – 9 000) Bq/kg\nMetoda spektrometrii promieniowania gamma PB 33 wydanie 2 z dnia 22.04.2024 r. Surowce, materialy budowlane, Odpady: kod 10 01 01, 10 01 02, 03 01 05, 03 03 05, 10 01 03, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 81, 10 01 82 \nZakres:\nStezenie aktywnosci radionuklidu 40K\nZakres (60 – 9 000) Bq/kg\nMetoda spektrometrii promieniowania gamma PB 33 wydanie 2 z dnia 22.04.2024 r.","categories":["materials","environment","construction"],"row_index":165,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Raw materials, building materials, Waste: code 10 01 01, 10 01 02, 03 01 05, 03 03 05, 10 01 03, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 81, 10 01 82 Gamma-ray spectrometry method Radionuclide activity concentration Range PB 33 wydanie 2 z dnia 22.04.2024 r.","parameters_zh":[{"name":"放射性核素活度浓度","range":"40K"},{"name":"范围","range":"(60 – 9 000) Bq/kg"}],"search_zh":"原料、建筑材料、废物：代码 10 01 01、10 01 02、03 01 05、03 03 05、10 01 03、10 01 17、10 01 24、10 01 25、10 01 80、10 01 81、10 01 82 γ 能谱法 放射性核素活度浓度 范围 PB 33 wydanie 2 z dnia 22.04.2024 r.","technique_zh":"γ 能谱法","test_object_zh":"原料、建筑材料、废物：代码 10 01 01、10 01 02、03 01 05、03 03 05、10 01 03、10 01 17、10 01 24、10 01 25、10 01 80、10 01 81、10 01 82"},{"_id":"6a5dc9bbf1c10c8ce825e072","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Surowce, materiały budowlane, Odpady: kod 10 01 01, 10 01 02, 03 01 05, 03 03 05, 10 01 03, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 81, 10 01 82","test_object_en":"Raw materials, building materials, Waste: code 10 01 01, 10 01 02, 03 01 05, 03 03 05, 10 01 03, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 81, 10 01 82","methodology":"","methodology_en":null,"parameters":[{"name":"Stężenie aktywności radionuklidu","range":"214Bi"},{"name":"Zakres","range":"(15 – 5 000) Bq/kg"}],"parameters_en":[{"name":"Radionuclide activity concentration","range":"214Bi"},{"name":"Range","range":"(15 – 5 000) Bq/kg"}],"technique":"Metoda spektrometrii promieniowania gamma","techniques":["Metoda spektrometrii promieniowania gamma"],"technique_en":"Gamma-ray spectrometry method","computed":[],"computed_en":[],"activity":"\nZakres:\nStężenie aktywności radionuklidu 214Bi\nZakres (15 – 5 000) Bq/kg\nMetoda spektrometrii promieniowania gamma","reference":"PB 33 wydanie 2 z dnia 22.04.2024 r.","norm_bases":["PB 33 wydanie 2 z dnia 22.04.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Surowce, materiały budowlane, Odpady: kod 10 01 01, 10 01 02, 03 01 05, 03 03 05, 10 01 03, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 81, 10 01 82 \nZakres:\nStężenie aktywności radionuklidu 214Bi\nZakres (15 – 5 000) Bq/kg\nMetoda spektrometrii promieniowania gamma PB 33 wydanie 2 z dnia 22.04.2024 r. Surowce, materialy budowlane, Odpady: kod 10 01 01, 10 01 02, 03 01 05, 03 03 05, 10 01 03, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 81, 10 01 82 \nZakres:\nStezenie aktywnosci radionuklidu 214Bi\nZakres (15 – 5 000) Bq/kg\nMetoda spektrometrii promieniowania gamma PB 33 wydanie 2 z dnia 22.04.2024 r.","categories":["materials","environment","construction"],"row_index":166,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Raw materials, building materials, Waste: code 10 01 01, 10 01 02, 03 01 05, 03 03 05, 10 01 03, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 81, 10 01 82 Gamma-ray spectrometry method Radionuclide activity concentration Range PB 33 wydanie 2 z dnia 22.04.2024 r.","parameters_zh":[{"name":"放射性核素活度浓度","range":"214Bi"},{"name":"范围","range":"(15 – 5 000) Bq/kg"}],"search_zh":"原料、建筑材料、废物：代码 10 01 01、10 01 02、03 01 05、03 03 05、10 01 03、10 01 17、10 01 24、10 01 25、10 01 80、10 01 81、10 01 82 γ 能谱法 放射性核素活度浓度 范围 PB 33 wydanie 2 z dnia 22.04.2024 r.","technique_zh":"γ 能谱法","test_object_zh":"原料、建筑材料、废物：代码 10 01 01、10 01 02、03 01 05、03 03 05、10 01 03、10 01 17、10 01 24、10 01 25、10 01 80、10 01 81、10 01 82"},{"_id":"6a5dc9bbf1c10c8ce825e073","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Surowce, materiały budowlane, Odpady: kod 10 01 01, 10 01 02, 03 01 05, 03 03 05, 10 01 03, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 81, 10 01 82","test_object_en":"Raw materials, building materials, Waste: code 10 01 01, 10 01 02, 03 01 05, 03 03 05, 10 01 03, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 81, 10 01 82","methodology":"","methodology_en":null,"parameters":[{"name":"Stężenie aktywności radionuklidu","range":"208Tl"},{"name":"Zakres","range":"(7 – 5 000) Bq/kg"}],"parameters_en":[{"name":"Radionuclide activity concentration","range":"208Tl"},{"name":"Range","range":"(7 – 5 000) Bq/kg"}],"technique":"Metoda spektrometrii promieniowania gamma","techniques":["Metoda spektrometrii promieniowania gamma"],"technique_en":"Gamma-ray spectrometry method","computed":[],"computed_en":[],"activity":"\nZakres:\nStężenie aktywności radionuklidu 208Tl\nZakres (7 – 5 000) Bq/kg\nMetoda spektrometrii promieniowania gamma","reference":"PB 33 wydanie 2 z dnia 22.04.2024 r.","norm_bases":["PB 33 wydanie 2 z dnia 22.04.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Surowce, materiały budowlane, Odpady: kod 10 01 01, 10 01 02, 03 01 05, 03 03 05, 10 01 03, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 81, 10 01 82 \nZakres:\nStężenie aktywności radionuklidu 208Tl\nZakres (7 – 5 000) Bq/kg\nMetoda spektrometrii promieniowania gamma PB 33 wydanie 2 z dnia 22.04.2024 r. Surowce, materialy budowlane, Odpady: kod 10 01 01, 10 01 02, 03 01 05, 03 03 05, 10 01 03, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 81, 10 01 82 \nZakres:\nStezenie aktywnosci radionuklidu 208Tl\nZakres (7 – 5 000) Bq/kg\nMetoda spektrometrii promieniowania gamma PB 33 wydanie 2 z dnia 22.04.2024 r.","categories":["materials","environment","construction"],"row_index":167,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Raw materials, building materials, Waste: code 10 01 01, 10 01 02, 03 01 05, 03 03 05, 10 01 03, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 81, 10 01 82 Gamma-ray spectrometry method Radionuclide activity concentration Range PB 33 wydanie 2 z dnia 22.04.2024 r.","parameters_zh":[{"name":"放射性核素活度浓度","range":"208Tl"},{"name":"范围","range":"(7 – 5 000) Bq/kg"}],"search_zh":"原料、建筑材料、废物：代码 10 01 01、10 01 02、03 01 05、03 03 05、10 01 03、10 01 17、10 01 24、10 01 25、10 01 80、10 01 81、10 01 82 γ 能谱法 放射性核素活度浓度 范围 PB 33 wydanie 2 z dnia 22.04.2024 r.","technique_zh":"γ 能谱法","test_object_zh":"原料、建筑材料、废物：代码 10 01 01、10 01 02、03 01 05、03 03 05、10 01 03、10 01 17、10 01 24、10 01 25、10 01 80、10 01 81、10 01 82"},{"_id":"6a5dc9bbf1c10c8ce825e074","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Surowce, materiały budowlane, Odpady: kod 10 01 01, 10 01 02, 03 01 05, 03 03 05, 10 01 03, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 81, 10 01 82","test_object_en":"Raw materials, building materials, Waste: code 10 01 01, 10 01 02, 03 01 05, 03 03 05, 10 01 03, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 81, 10 01 82","methodology":"","methodology_en":null,"parameters":[{"name":"Stężenie aktywności radionuklidu","range":"226Ra"},{"name":"(z obliczeń)"}],"parameters_en":[{"name":"Radionuclide activity concentration","range":"226Ra"},{"name":"(calculated)"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"\nZakres:\nStężenie aktywności radionuklidu 226Ra\n(z obliczeń)","reference":"PB 33 wydanie 2 z dnia 22.04.2024 r.","norm_bases":["PB 33 wydanie 2 z dnia 22.04.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Surowce, materiały budowlane, Odpady: kod 10 01 01, 10 01 02, 03 01 05, 03 03 05, 10 01 03, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 81, 10 01 82 \nZakres:\nStężenie aktywności radionuklidu 226Ra\n(z obliczeń) PB 33 wydanie 2 z dnia 22.04.2024 r. Surowce, materialy budowlane, Odpady: kod 10 01 01, 10 01 02, 03 01 05, 03 03 05, 10 01 03, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 81, 10 01 82 \nZakres:\nStezenie aktywnosci radionuklidu 226Ra\n(z obliczen) PB 33 wydanie 2 z dnia 22.04.2024 r.","categories":["materials","environment","construction"],"row_index":168,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Raw materials, building materials, Waste: code 10 01 01, 10 01 02, 03 01 05, 03 03 05, 10 01 03, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 81, 10 01 82 Radionuclide activity concentration (calculated) PB 33 wydanie 2 z dnia 22.04.2024 r.","parameters_zh":[{"name":"放射性核素活度浓度","range":"226Ra"},{"name":"（计算得出）"}],"search_zh":"原料、建筑材料、废物：代码 10 01 01、10 01 02、03 01 05、03 03 05、10 01 03、10 01 17、10 01 24、10 01 25、10 01 80、10 01 81、10 01 82 放射性核素活度浓度 （计算得出） PB 33 wydanie 2 z dnia 22.04.2024 r.","test_object_zh":"原料、建筑材料、废物：代码 10 01 01、10 01 02、03 01 05、03 03 05、10 01 03、10 01 17、10 01 24、10 01 25、10 01 80、10 01 81、10 01 82"},{"_id":"6a5dc9bbf1c10c8ce825e075","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Surowce, materiały budowlane, Odpady: kod 10 01 01, 10 01 02, 03 01 05, 03 03 05, 10 01 03, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 81, 10 01 82","test_object_en":"Raw materials, building materials, Waste: code 10 01 01, 10 01 02, 03 01 05, 03 03 05, 10 01 03, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 81, 10 01 82","methodology":"","methodology_en":null,"parameters":[{"name":"Stężenie aktywności radionuklidu","range":"232Th"},{"name":"(z obliczeń)"}],"parameters_en":[{"name":"Radionuclide activity concentration","range":"232Th"},{"name":"(calculated)"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"\nZakres:\nStężenie aktywności radionuklidu 232Th\n(z obliczeń)","reference":"PB 33 wydanie 2 z dnia 22.04.2024 r.","norm_bases":["PB 33 wydanie 2 z dnia 22.04.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Surowce, materiały budowlane, Odpady: kod 10 01 01, 10 01 02, 03 01 05, 03 03 05, 10 01 03, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 81, 10 01 82 \nZakres:\nStężenie aktywności radionuklidu 232Th\n(z obliczeń) PB 33 wydanie 2 z dnia 22.04.2024 r. Surowce, materialy budowlane, Odpady: kod 10 01 01, 10 01 02, 03 01 05, 03 03 05, 10 01 03, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 81, 10 01 82 \nZakres:\nStezenie aktywnosci radionuklidu 232Th\n(z obliczen) PB 33 wydanie 2 z dnia 22.04.2024 r.","categories":["materials","environment","construction"],"row_index":169,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Raw materials, building materials, Waste: code 10 01 01, 10 01 02, 03 01 05, 03 03 05, 10 01 03, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 81, 10 01 82 Radionuclide activity concentration (calculated) PB 33 wydanie 2 z dnia 22.04.2024 r.","parameters_zh":[{"name":"放射性核素活度浓度","range":"232Th"},{"name":"（计算得出）"}],"search_zh":"原料、建筑材料、废物：代码 10 01 01、10 01 02、03 01 05、03 03 05、10 01 03、10 01 17、10 01 24、10 01 25、10 01 80、10 01 81、10 01 82 放射性核素活度浓度 （计算得出） PB 33 wydanie 2 z dnia 22.04.2024 r.","test_object_zh":"原料、建筑材料、废物：代码 10 01 01、10 01 02、03 01 05、03 03 05、10 01 03、10 01 17、10 01 24、10 01 25、10 01 80、10 01 81、10 01 82"},{"_id":"6a5dc9bbf1c10c8ce825e076","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Surowce, materiały budowlane, Odpady: kod 10 01 01, 10 01 02, 03 01 05, 03 03 05, 10 01 03, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 81, 10 01 82","test_object_en":"Raw materials, building materials, Waste: code 10 01 01, 10 01 02, 03 01 05, 03 03 05, 10 01 03, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 81, 10 01 82","methodology":"Wskaźnik stężenia promieniotwórczego I (z obliczeń)","methodology_en":"Activity concentration index I (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik stężenia promieniotwórczego I (z obliczeń)","reference":"PB 33 wydanie 2 z dnia 22.04.2024 r.","norm_bases":["PB 33 wydanie 2 z dnia 22.04.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Surowce, materiały budowlane, Odpady: kod 10 01 01, 10 01 02, 03 01 05, 03 03 05, 10 01 03, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 81, 10 01 82 Wskaźnik stężenia promieniotwórczego I (z obliczeń) PB 33 wydanie 2 z dnia 22.04.2024 r. Surowce, materialy budowlane, Odpady: kod 10 01 01, 10 01 02, 03 01 05, 03 03 05, 10 01 03, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 81, 10 01 82 Wskaznik stezenia promieniotworczego I (z obliczen) PB 33 wydanie 2 z dnia 22.04.2024 r.","categories":["materials","environment","construction"],"row_index":170,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Raw materials, building materials, Waste: code 10 01 01, 10 01 02, 03 01 05, 03 03 05, 10 01 03, 10 01 17, 10 01 24, 10 01 25, 10 01 80, 10 01 81, 10 01 82 Activity concentration index I (calculated) PB 33 wydanie 2 z dnia 22.04.2024 r.","methodology_zh":"放射性浓度指数 I（计算得出）","search_zh":"原料、建筑材料、废物：代码 10 01 01、10 01 02、03 01 05、03 03 05、10 01 03、10 01 17、10 01 24、10 01 25、10 01 80、10 01 81、10 01 82 放射性浓度指数 I（计算得出） PB 33 wydanie 2 z dnia 22.04.2024 r.","test_object_zh":"原料、建筑材料、废物：代码 10 01 01、10 01 02、03 01 05、03 03 05、10 01 03、10 01 17、10 01 24、10 01 25、10 01 80、10 01 81、10 01 82"},{"_id":"6a5dc9bbf1c10c8ce825e077","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Kruszywa","test_object_en":"Aggregates","methodology":"Skład ziarnowy","methodology_en":"Particle size distribution","parameters":[{"name":"Zakres","range":"(0,063 – 90,0) mm"}],"parameters_en":[{"name":"Range","range":"(0,063 – 90,0) mm"}],"technique":"Metoda przesiewania","techniques":["Metoda przesiewania"],"technique_en":"Sieving method","computed":[],"computed_en":[],"activity":"Skład ziarnowy\nZakres (0,063 – 90,0) mm\nMetoda przesiewania","reference":"PN-EN 933-1:2012","norm_bases":["PN-EN 933-1:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywa Skład ziarnowy\nZakres (0,063 – 90,0) mm\nMetoda przesiewania PN-EN 933-1:2012 Kruszywa Sklad ziarnowy\nZakres (0,063 – 90,0) mm\nMetoda przesiewania PN-EN 933-1:2012","categories":["other"],"row_index":171,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Aggregates Particle size distribution Sieving method Range PN-EN 933-1:2012","parameters_zh":[{"name":"范围","range":"(0,063 – 90,0) mm"}],"search_zh":"骨料 粒度分布 筛分法 范围 PN-EN 933-1:2012","test_object_zh":"骨料","methodology_zh":"粒度分布","technique_zh":"筛分法"},{"_id":"6a5dc9bbf1c10c8ce825e078","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Kruszywa","test_object_en":"Aggregates","methodology":"Zawartość pyłów <0,063 mm","methodology_en":"Fines content <0,063 mm","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość pyłów <0,063 mm","reference":"PN-EN 933-1:2012","norm_bases":["PN-EN 933-1:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywa Zawartość pyłów <0,063 mm PN-EN 933-1:2012 Kruszywa Zawartosc pylow <0,063 mm PN-EN 933-1:2012","categories":["other"],"row_index":172,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Aggregates Fines content <0,063 mm PN-EN 933-1:2012","search_zh":"骨料 PN-EN 933-1:2012","test_object_zh":"骨料"},{"_id":"6a5dc9bbf1c10c8ce825e079","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Kruszywa","test_object_en":"Aggregates","methodology":"Zawartość ziaren drobnych <0,5 mm","methodology_en":"Content of fine grains <0,5 mm","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość ziaren drobnych <0,5 mm","reference":"PN-EN 933-1:2012","norm_bases":["PN-EN 933-1:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywa Zawartość ziaren drobnych <0,5 mm PN-EN 933-1:2012 Kruszywa Zawartosc ziaren drobnych <0,5 mm PN-EN 933-1:2012","categories":["other"],"row_index":173,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Aggregates Content of fine grains <0,5 mm PN-EN 933-1:2012","search_zh":"骨料 PN-EN 933-1:2012","test_object_zh":"骨料"},{"_id":"6a5dc9bbf1c10c8ce825e07a","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Kruszywa","test_object_en":"Aggregates","methodology":"Wskaźnik płaskości","methodology_en":"Flakiness index","parameters":[{"name":"Zakres","range":"(4 – 100) mm"}],"parameters_en":[{"name":"Range","range":"(4 – 100) mm"}],"technique":"Metoda przesiewania","techniques":["Metoda przesiewania"],"technique_en":"Sieving method","computed":[],"computed_en":[],"activity":"Wskaźnik płaskości\nZakres (4 – 100) mm\nMetoda przesiewania","reference":"PN-EN 933-3:2012 WTWiOPK Id-110:2024","norm_bases":["PN-EN 933-3:2012 WTWiOPK Id-110:2024"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywa Wskaźnik płaskości\nZakres (4 – 100) mm\nMetoda przesiewania PN-EN 933-3:2012 WTWiOPK Id-110:2024 Kruszywa Wskaznik plaskosci\nZakres (4 – 100) mm\nMetoda przesiewania PN-EN 933-3:2012 WTWiOPK Id-110:2024","categories":["other"],"row_index":174,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Aggregates Flakiness index Sieving method Range PN-EN 933-3:2012 WTWiOPK Id-110:2024","parameters_zh":[{"name":"范围","range":"(4 – 100) mm"}],"search_zh":"骨料 片状指数 筛分法 范围 PN-EN 933-3:2012 WTWiOPK Id-110:2024","test_object_zh":"骨料","technique_zh":"筛分法","methodology_zh":"片状指数"},{"_id":"6a5dc9bbf1c10c8ce825e07b","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Kruszywa","test_object_en":"Aggregates","methodology":"Wskaźnik kształtu","methodology_en":"Shape index","parameters":[{"name":"Schultza"}],"parameters_en":[{"name":"Schultz"}],"technique":"Metoda za pomocą suwmiarki","techniques":["Metoda za pomocą suwmiarki"],"technique_en":"Method using a calliper","computed":[],"computed_en":[],"activity":"Wskaźnik kształtu\nSchultza\nMetoda za pomocą suwmiarki","reference":"PN-EN 933-4:2008","norm_bases":["PN-EN 933-4:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywa Wskaźnik kształtu\nSchultza\nMetoda za pomocą suwmiarki PN-EN 933-4:2008 Kruszywa Wskaznik ksztaltu\nSchultza\nMetoda za pomoca suwmiarki PN-EN 933-4:2008","categories":["other"],"row_index":175,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Aggregates Shape index Method using a calliper Schultz PN-EN 933-4:2008","search_zh":"骨料 形状指数 PN-EN 933-4:2008","test_object_zh":"骨料","methodology_zh":"形状指数"},{"_id":"6a5dc9bbf1c10c8ce825e07c","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Kruszywa","test_object_en":"Aggregates","methodology":"Odporność na ścieranie","methodology_en":"Abrasion resistance","parameters":[],"parameters_en":[],"technique":"Metoda mikro-Deval","techniques":["Metoda mikro-Deval"],"technique_en":"Micro-Deval method","computed":[],"computed_en":[],"activity":"Odporność na ścieranie\nMetoda mikro-Deval","reference":"PN-EN 1097-1:2024-05","norm_bases":["PN-EN 1097-1:2024-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywa Odporność na ścieranie\nMetoda mikro-Deval PN-EN 1097-1:2024-05 Kruszywa Odpornosc na scieranie\nMetoda mikro-Deval PN-EN 1097-1:2024-05","categories":["other"],"row_index":176,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Aggregates Abrasion resistance Micro-Deval method PN-EN 1097-1:2024-05","search_zh":"骨料 耐磨性 微 Deval 法 PN-EN 1097-1:2024-05","test_object_zh":"骨料","methodology_zh":"耐磨性","technique_zh":"微 Deval 法"},{"_id":"6a5dc9bbf1c10c8ce825e07d","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Kruszywa","test_object_en":"Aggregates","methodology":"Odporność na rozdrabnianie","methodology_en":"Resistance to fragmentation","parameters":[],"parameters_en":[],"technique":"Metoda Los Angeles","techniques":["Metoda Los Angeles"],"technique_en":"Los Angeles method","computed":[],"computed_en":[],"activity":"Odporność na rozdrabnianie\nMetoda Los Angeles","reference":"PN-EN 1097-2:2020-09","norm_bases":["PN-EN 1097-2:2020-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywa Odporność na rozdrabnianie\nMetoda Los Angeles PN-EN 1097-2:2020-09 Kruszywa Odpornosc na rozdrabnianie\nMetoda Los Angeles PN-EN 1097-2:2020-09","categories":["other"],"row_index":177,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Aggregates Resistance to fragmentation Los Angeles method PN-EN 1097-2:2020-09","search_zh":"骨料 抗破碎性 洛杉矶法 PN-EN 1097-2:2020-09","test_object_zh":"骨料","methodology_zh":"抗破碎性","technique_zh":"洛杉矶法"},{"_id":"6a5dc9bbf1c10c8ce825e07e","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Kruszywa","test_object_en":"Aggregates","methodology":"Zanieczyszczenia – obce i stałe","methodology_en":"Impurities – foreign and solid","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Zanieczyszczenia – obce i stałe","reference":"PN-B-06714/12:1976 WTWiOPK Id-110:2024","norm_bases":["PN-B-06714/12:1976 WTWiOPK Id-110:2024"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywa Zanieczyszczenia – obce i stałe PN-B-06714/12:1976 WTWiOPK Id-110:2024 Kruszywa Zanieczyszczenia – obce i stale PN-B-06714/12:1976 WTWiOPK Id-110:2024","categories":["other"],"row_index":178,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Aggregates Impurities – foreign and solid PN-B-06714/12:1976 WTWiOPK Id-110:2024","search_zh":"骨料 PN-B-06714/12:1976 WTWiOPK Id-110:2024","test_object_zh":"骨料"},{"_id":"6a5dc9bbf1c10c8ce825e07f","lab_id":"69ad52a3de79e566650fb37e","country":"PL","accr_number":"AB 687","accr_body":"PCA","test_object":"Kruszywa","test_object_en":"Aggregates","methodology":"Pobieranie próbek","methodology_en":"Sampling","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek","reference":"PN-EN 932-1:1999 p. 8.2 i 8.8","norm_bases":["PN-EN 932-1:1999 p. 8.2 i 8.8"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywa Pobieranie próbek PN-EN 932-1:1999 p. 8.2 i 8.8 Kruszywa Pobieranie probek PN-EN 932-1:1999 p. 8.2 i 8.8","categories":["other"],"row_index":179,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Aggregates Sampling PN-EN 932-1:1999 p. 8.2 i 8.8","methodology_zh":"样品采集","search_zh":"骨料 样品采集 PN-EN 932-1:1999 p. 8.2 i 8.8","test_object_zh":"骨料"}],"has_pdf":true}