{"lab":{"_id":"69ad52a3de79e566650fb37a","accr_number":"AB 682","country":"PL","accr_body":"PCA","address":"W JELENIEJ GÓRZE, ul. Kasprowicza 17, 58-500 Jelenia Góra","categories":["water","microbiology","environment","food"],"city":"Jelenia Góra","imported_at":"2026-03-08T10:42:43.265Z","methods_count":57,"name":"POWIATOWA STACJA SANITARNO-EPIDEMIOLOGICZNA","parse_status":"parsed","parse_version":3,"pdf_files":["AB_682.pdf"],"scope_summary":"","search_text":"powiatowa stacja sanitarno-epidemiologiczna w jeleniej górze, ul. kasprowicza 17, 58-500 jelenia góra other water pharma electronics microbiology food automotive materials environment metrology construction","status":"active","updated_at":"2026-03-08T14:51:35.061Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:35.061Z","location":{"type":"Point","coordinates":[15.7197,50.9044]},"email_confidence":"high","email_mx":true,"email_source":"https://www.gov.pl/web/psse-jelenia-gora/kontakt-z-psse-w-jeleniej-gorze","fields_of_testing":[{"codes":"C/28; C/29","pl":"Badania chemiczne wody, wody do spożycia przez ludzi","en":"Chemical tests of water, drinking water,"},{"codes":"G/33","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne): - środowisko pracy (czynniki szkodliwe i uciążliwe – hałas, drgania)","en":"Tests concerning environmental engineering (environmental and climatic) – workplace (harmful and nuisance factors – noise, vibration)"},{"codes":"K/3; K/22","pl":"Badania mikrobiologiczne obiektów i materiałów biologicznych przeznaczonych do badań, żywności","en":"Microbiological tests of biological items and materials for testing, food"},{"codes":"K/28/P; K/29/P","pl":"Badania mikrobiologiczne i pobieranie próbek wody, wody do spożycia przez ludzi/","en":"Microbiological tests and sampling of water, drinking water"},{"codes":"N/33/P","pl":"Badania właściwości fizycznych i pobieranie próbek – środowisko pracy (czynniki szkodliwe - powietrze)","en":"Tests of physical properties and sampling – working enviroment (harmful factors – air)"},{"codes":"N/28; N/29","pl":"Badania właściwości fizycznych wody, wody do spożycia przez ludzi","en":"Tests of physical properties water, drinking water"}],"issue":{"no":"20","date":"26.01.2026"},"parse_date":"2026-07-20T07:09:47.496Z","parse_source":"script-pdfplumber","map_coord":[50.899927,15.729135],"map_geo":"nominatim-street","has_en":true,"category_counts":{"water":41,"microbiology":10,"environment":9,"food":5,"construction":2,"materials":2,"pharma":2},"category_scores":{"water":23.68,"microbiology":1.41,"environment":1.14,"food":0.35,"construction":0.06,"materials":0.06,"pharma":0.06},"has_zh":true},"methods":[{"_id":"6a5dc9bbf1c10c8ce825df89","lab_id":"69ad52a3de79e566650fb37a","country":"PL","accr_number":"AB 682","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"2,0 – 10,0"}],"parameters_en":[{"name":"Range","range":"2,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 2,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi pH\nZakres 2,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, Woda do spozycia przez ludzi pH\nZakres 2,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 10,0"}],"search_zh":"水、生活饮用水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9bbf1c10c8ce825df8a","lab_id":"69ad52a3de79e566650fb37a","country":"PL","accr_number":"AB 682","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Barwa","methodology_en":"Colour","parameters":[{"name":"Zakres","range":"(5 – 70) mg/l Pt"}],"parameters_en":[{"name":"Range","range":"(5 – 70) mg/l Pt"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"technique_en":"Visual method","computed":[],"computed_en":[],"activity":"Barwa\nZakres (5 – 70) mg/l Pt\nMetoda wizualna","reference":"PN-EN ISO 7887:2012+Ap1: 2015-06","norm_bases":["PN-EN ISO 7887:2012+Ap1: 2015-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Barwa\nZakres (5 – 70) mg/l Pt\nMetoda wizualna PN-EN ISO 7887:2012+Ap1: 2015-06 Woda, Woda do spozycia przez ludzi Barwa\nZakres (5 – 70) mg/l Pt\nMetoda wizualna PN-EN ISO 7887:2012+Ap1: 2015-06","categories":["water"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Colour Visual method Range PN-EN ISO 7887:2012+Ap1: 2015-06","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(5 – 70) mg/l Pt"}],"search_zh":"水、生活饮用水 色度 目视法 范围 PN-EN ISO 7887:2012+Ap1: 2015-06","technique_zh":"目视法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9bbf1c10c8ce825df8b","lab_id":"69ad52a3de79e566650fb37a","country":"PL","accr_number":"AB 682","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Mętność","methodology_en":"Turbidity","parameters":[{"name":"Zakres","range":"(0,10 – 10) NTU"}],"parameters_en":[{"name":"Range","range":"(0,10 – 10) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"technique_en":"Nephelometric method","computed":[],"computed_en":[],"activity":"Mętność\nZakres (0,10 – 10) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Mętność\nZakres (0,10 – 10) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda, Woda do spozycia przez ludzi Metnosc\nZakres (0,10 – 10) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,10 – 10) NTU"}],"search_zh":"水、生活饮用水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9bbf1c10c8ce825df8c","lab_id":"69ad52a3de79e566650fb37a","country":"PL","accr_number":"AB 682","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Przewodność elektryczna właściwa","methodology_en":"Electrical conductivity","parameters":[{"name":"Zakres","range":"(5 – 5000) μS/cm"}],"parameters_en":[{"name":"Range","range":"(5 – 5000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"technique_en":"Conductometric method","computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa\nZakres (5 – 5000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Przewodność elektryczna właściwa\nZakres (5 – 5000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, Woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa\nZakres (5 – 5000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Electrical conductivity Conductometric method Range PN-EN 27888:1999","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(5 – 5000) μS/cm"}],"search_zh":"水、生活饮用水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9bbf1c10c8ce825df8d","lab_id":"69ad52a3de79e566650fb37a","country":"PL","accr_number":"AB 682","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Stężenie sumaryczne wapnia i magnezu (Twardość)","methodology_en":"Total concentration of calcium and magnesium (Hardness)","parameters":[{"name":"Zakres","range":"(4 – 600) mg/l CaCO3"}],"parameters_en":[{"name":"Range","range":"(4 – 600) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie sumaryczne wapnia i magnezu (Twardość)\nZakres (4 – 600) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie sumaryczne wapnia i magnezu (Twardość)\nZakres (4 – 600) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999 Woda, Woda do spozycia przez ludzi Stezenie sumaryczne wapnia i magnezu (Twardosc)\nZakres (4 – 600) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Total concentration of calcium and magnesium (Hardness) Titrimetric method Range PN-ISO 6059:1999","parameters_zh":[{"name":"范围","range":"(4 – 600) mg/l CaCO3"}],"search_zh":"水、生活饮用水 滴定法 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9bbf1c10c8ce825df8e","lab_id":"69ad52a3de79e566650fb37a","country":"PL","accr_number":"AB 682","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Stężenie wapnia","methodology_en":"Calcium concentration","parameters":[{"name":"Zakres","range":"(3 – 80) mg/l"}],"parameters_en":[{"name":"Range","range":"(3 – 80) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie wapnia\nZakres (3 – 80) mg/l\nMetoda miareczkowa","reference":"PN-ISO 6058:1999","norm_bases":["PN-ISO 6058:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie wapnia\nZakres (3 – 80) mg/l\nMetoda miareczkowa PN-ISO 6058:1999 Woda, Woda do spozycia przez ludzi Stezenie wapnia\nZakres (3 – 80) mg/l\nMetoda miareczkowa PN-ISO 6058:1999","categories":["water"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Calcium concentration Titrimetric method Range PN-ISO 6058:1999","parameters_zh":[{"name":"范围","range":"(3 – 80) mg/l"}],"search_zh":"水、生活饮用水 钙浓度 滴定法 范围 PN-ISO 6058:1999","technique_zh":"滴定法","test_object_zh":"水、生活饮用水","methodology_zh":"钙浓度"},{"_id":"6a5dc9bbf1c10c8ce825df8f","lab_id":"69ad52a3de79e566650fb37a","country":"PL","accr_number":"AB 682","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Stężenie magnezu (z obliczeń)","methodology_en":"Magnesium concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie magnezu (z obliczeń)","reference":"PN-C-04554-4:1999 załącznik A","norm_bases":["PN-C-04554-4:1999 załącznik A"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie magnezu (z obliczeń) PN-C-04554-4:1999 załącznik A Woda, Woda do spozycia przez ludzi Stezenie magnezu (z obliczen) PN-C-04554-4:1999 zalacznik A","categories":["water"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Magnesium concentration (calculated) PN-C-04554-4:1999 załącznik A","search_zh":"水、生活饮用水 镁浓度（计算值） PN-C-04554-4:1999 załącznik A","test_object_zh":"水、生活饮用水","methodology_zh":"镁浓度（计算值）"},{"_id":"6a5dc9bbf1c10c8ce825df90","lab_id":"69ad52a3de79e566650fb37a","country":"PL","accr_number":"AB 682","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Stężenie żelaza ogólnego","methodology_en":"Total iron concentration","parameters":[{"name":"Zakres","range":"(0,02 – 10,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,02 – 10,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie żelaza ogólnego\nZakres (0,02 – 10,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001+Ap1:2016-06","norm_bases":["PN-ISO 6332:2001+Ap1:2016-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie żelaza ogólnego\nZakres (0,02 – 10,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06 Woda, Woda do spozycia przez ludzi Stezenie zelaza ogolnego\nZakres (0,02 – 10,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06","categories":["water"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Total iron concentration Spectrophotometric method Range PN-ISO 6332:2001+Ap1:2016-06","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(0,02 – 10,0) mg/l"}],"search_zh":"水、生活饮用水 总铁浓度 分光光度法 范围 PN-ISO 6332:2001+Ap1:2016-06","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9bbf1c10c8ce825df91","lab_id":"69ad52a3de79e566650fb37a","country":"PL","accr_number":"AB 682","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Stężenie jonu amonowego","methodology_en":"Ammonium ion concentration","parameters":[{"name":"Zakres","range":"(0,05 – 0,97) mg/l"},{"name":"Stężenie amoniaku"},{"name":"Zakres","range":"(0,05 – 0,97) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,05 – 0,97) mg/l"},{"name":"Ammonia concentration"},{"name":"Range","range":"(0,05 – 0,97) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie jonu amonowego\nZakres:\nZakres (0,05 – 0,97) mg/l\nStężenie amoniaku\nZakres (0,05 – 0,97) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie jonu amonowego\nZakres:\nZakres (0,05 – 0,97) mg/l\nStężenie amoniaku\nZakres (0,05 – 0,97) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, Woda do spozycia przez ludzi Stezenie jonu amonowego\nZakres:\nZakres (0,05 – 0,97) mg/l\nStezenie amoniaku\nZakres (0,05 – 0,97) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Ammonium ion concentration Spectrophotometric method Range Ammonia concentration Range PN-ISO 7150-1:2002","methodology_zh":"铵离子浓度","parameters_zh":[{"name":"范围","range":"(0,05 – 0,97) mg/l"},{"name":"氨浓度"},{"name":"范围","range":"(0,05 – 0,97) mg/l"}],"search_zh":"水、生活饮用水 铵离子浓度 分光光度法 范围 氨浓度 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9bbf1c10c8ce825df92","lab_id":"69ad52a3de79e566650fb37a","country":"PL","accr_number":"AB 682","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Stężenie azotynów","methodology_en":"Nitrite concentration","parameters":[{"name":"Zakres","range":"(0,04 – 0,820) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,04 – 0,820) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotynów\nZakres (0,04 – 0,820) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie azotynów\nZakres (0,04 – 0,820) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, Woda do spozycia przez ludzi Stezenie azotynow\nZakres (0,04 – 0,820) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Nitrite concentration Spectrophotometric method Range PN-EN 26777:1999","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,04 – 0,820) mg/l"}],"search_zh":"水、生活饮用水 亚硝酸盐浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9bbf1c10c8ce825df93","lab_id":"69ad52a3de79e566650fb37a","country":"PL","accr_number":"AB 682","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Stężenie azotanów","methodology_en":"Nitrate concentration","parameters":[{"name":"Zakres","range":"(0,70 – 90) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,70 – 90) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotanów\nZakres (0,70 – 90) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576.08","norm_bases":["PN-82/C-04576.08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie azotanów\nZakres (0,70 – 90) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08 Woda, Woda do spozycia przez ludzi Stezenie azotanow\nZakres (0,70 – 90) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08","categories":["water"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Nitrate concentration Spectrophotometric method Range PN-82/C-04576.08","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,70 – 90) mg/l"}],"search_zh":"水、生活饮用水 硝酸盐浓度 分光光度法 范围 PN-82/C-04576.08","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9bbf1c10c8ce825df94","lab_id":"69ad52a3de79e566650fb37a","country":"PL","accr_number":"AB 682","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Stężenie chlorków","methodology_en":"Chloride concentration","parameters":[{"name":"Zakres","range":"(7 – 250) mg/l"}],"parameters_en":[{"name":"Range","range":"(7 – 250) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie chlorków\nZakres (7 – 250) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie chlorków\nZakres (7 – 250) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda, Woda do spozycia przez ludzi Stezenie chlorkow\nZakres (7 – 250) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Chloride concentration Titrimetric method Range PN-ISO 9297:1994","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(7 – 250) mg/l"}],"search_zh":"水、生活饮用水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9bbf1c10c8ce825df95","lab_id":"69ad52a3de79e566650fb37a","country":"PL","accr_number":"AB 682","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Stężenie fluorków","methodology_en":"Fluoride concentration","parameters":[{"name":"Zakres","range":"(0,1 – 2) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,1 – 2) mg/l"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"Stężenie fluorków\nZakres (0,1 – 2) mg/l\nMetoda potencjometryczna","reference":"PN-78-C-04588/03","norm_bases":["PN-78-C-04588/03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie fluorków\nZakres (0,1 – 2) mg/l\nMetoda potencjometryczna PN-78-C-04588/03 Woda, Woda do spozycia przez ludzi Stezenie fluorkow\nZakres (0,1 – 2) mg/l\nMetoda potencjometryczna PN-78-C-04588/03","categories":["water"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Fluoride concentration Potentiometric method Range PN-78-C-04588/03","parameters_zh":[{"name":"范围","range":"(0,1 – 2) mg/l"}],"search_zh":"水、生活饮用水 氟化物浓度 电位法 范围 PN-78-C-04588/03","technique_zh":"电位法","test_object_zh":"水、生活饮用水","methodology_zh":"氟化物浓度"},{"_id":"6a5dc9bbf1c10c8ce825df96","lab_id":"69ad52a3de79e566650fb37a","country":"PL","accr_number":"AB 682","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Stężenie siarczanów","methodology_en":"Sulfate concentration","parameters":[{"name":"Zakres","range":"(2,5 – 250) mg/l"}],"parameters_en":[{"name":"Range","range":"(2,5 – 250) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie siarczanów\nZakres (2,5 – 250) mg/l\nMetoda spektrofotometryczna","reference":"PN-79-C-04566.10","norm_bases":["PN-79-C-04566.10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie siarczanów\nZakres (2,5 – 250) mg/l\nMetoda spektrofotometryczna PN-79-C-04566.10 Woda, Woda do spozycia przez ludzi Stezenie siarczanow\nZakres (2,5 – 250) mg/l\nMetoda spektrofotometryczna PN-79-C-04566.10","categories":["water"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Sulfate concentration Spectrophotometric method Range PN-79-C-04566.10","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(2,5 – 250) mg/l"}],"search_zh":"水、生活饮用水 硫酸盐浓度 分光光度法 范围 PN-79-C-04566.10","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9bbf1c10c8ce825df97","lab_id":"69ad52a3de79e566650fb37a","country":"PL","accr_number":"AB 682","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Indeks nadmanganianowy","methodology_en":"Permanganate index","parameters":[{"name":"Zakres","range":"(0,70 – 10) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(0,70 – 10) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Indeks nadmanganianowy\nZakres (0,70 – 10) mg/l O2\nMetoda miareczkowa","reference":"PN-EN ISO 8467: 2001","norm_bases":["PN-EN ISO 8467: 2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Indeks nadmanganianowy\nZakres (0,70 – 10) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467: 2001 Woda, Woda do spozycia przez ludzi Indeks nadmanganianowy\nZakres (0,70 – 10) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467: 2001","categories":["water"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Permanganate index Titrimetric method Range PN-EN ISO 8467: 2001","methodology_zh":"高锰酸盐指数","parameters_zh":[{"name":"范围","range":"(0,70 – 10) mg/l O2"}],"search_zh":"水、生活饮用水 高锰酸盐指数 滴定法 范围 PN-EN ISO 8467: 2001","technique_zh":"滴定法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9bbf1c10c8ce825df98","lab_id":"69ad52a3de79e566650fb37a","country":"PL","accr_number":"AB 682","accr_body":"PCA","test_object":"Woda, Woda na pływalniach / basenach kąpielowych","test_object_en":"Water, Water in swimming pools / bathing pools","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"2,0 – 10,0"}],"parameters_en":[{"name":"Range","range":"2,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 2,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda na pływalniach / basenach kąpielowych pH\nZakres 2,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, Woda na plywalniach / basenach kapielowych pH\nZakres 2,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water in swimming pools / bathing pools pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 10,0"}],"search_zh":"水、游泳池/泳池水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、游泳池/泳池水"},{"_id":"6a5dc9bbf1c10c8ce825df99","lab_id":"69ad52a3de79e566650fb37a","country":"PL","accr_number":"AB 682","accr_body":"PCA","test_object":"Woda, Woda na pływalniach / basenach kąpielowych","test_object_en":"Water, Water in swimming pools / bathing pools","methodology":"Mętność","methodology_en":"Turbidity","parameters":[{"name":"Zakres","range":"(0,10 – 10) NTU"}],"parameters_en":[{"name":"Range","range":"(0,10 – 10) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"technique_en":"Nephelometric method","computed":[],"computed_en":[],"activity":"Mętność\nZakres (0,10 – 10) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda na pływalniach / basenach kąpielowych Mętność\nZakres (0,10 – 10) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda, Woda na plywalniach / basenach kapielowych Metnosc\nZakres (0,10 – 10) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water in swimming pools / bathing pools Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,10 – 10) NTU"}],"search_zh":"水、游泳池/泳池水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"水、游泳池/泳池水"},{"_id":"6a5dc9bbf1c10c8ce825df9a","lab_id":"69ad52a3de79e566650fb37a","country":"PL","accr_number":"AB 682","accr_body":"PCA","test_object":"Woda, Woda na pływalniach / basenach kąpielowych","test_object_en":"Water, Water in swimming pools / bathing pools","methodology":"Stężenie żelaza ogólnego","methodology_en":"Total iron concentration","parameters":[{"name":"Zakres","range":"(0,02 – 0,60) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,02 – 0,60) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie żelaza ogólnego\nZakres (0,02 – 0,60) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001+Ap1:2016-06","norm_bases":["PN-ISO 6332:2001+Ap1:2016-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda na pływalniach / basenach kąpielowych Stężenie żelaza ogólnego\nZakres (0,02 – 0,60) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06 Woda, Woda na plywalniach / basenach kapielowych Stezenie zelaza ogolnego\nZakres (0,02 – 0,60) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06","categories":["water"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water in swimming pools / bathing pools Total iron concentration Spectrophotometric method Range PN-ISO 6332:2001+Ap1:2016-06","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(0,02 – 0,60) mg/l"}],"search_zh":"水、游泳池/泳池水 总铁浓度 分光光度法 范围 PN-ISO 6332:2001+Ap1:2016-06","technique_zh":"分光光度法","test_object_zh":"水、游泳池/泳池水"},{"_id":"6a5dc9bbf1c10c8ce825df9b","lab_id":"69ad52a3de79e566650fb37a","country":"PL","accr_number":"AB 682","accr_body":"PCA","test_object":"Woda, Woda na pływalniach / basenach kąpielowych","test_object_en":"Water, Water in swimming pools / bathing pools","methodology":"Stężenie azotanów","methodology_en":"Nitrate concentration","parameters":[{"name":"Zakres","range":"(0,70 – 90) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,70 – 90) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotanów\nZakres (0,70 – 90) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576.08","norm_bases":["PN-82/C-04576.08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda na pływalniach / basenach kąpielowych Stężenie azotanów\nZakres (0,70 – 90) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08 Woda, Woda na plywalniach / basenach kapielowych Stezenie azotanow\nZakres (0,70 – 90) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08","categories":["water"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water in swimming pools / bathing pools Nitrate concentration Spectrophotometric method Range PN-82/C-04576.08","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,70 – 90) mg/l"}],"search_zh":"水、游泳池/泳池水 硝酸盐浓度 分光光度法 范围 PN-82/C-04576.08","technique_zh":"分光光度法","test_object_zh":"水、游泳池/泳池水"},{"_id":"6a5dc9bbf1c10c8ce825df9c","lab_id":"69ad52a3de79e566650fb37a","country":"PL","accr_number":"AB 682","accr_body":"PCA","test_object":"Woda, Woda na pływalniach / basenach kąpielowych","test_object_en":"Water, Water in swimming pools / bathing pools","methodology":"Indeks nadmanganianowy","methodology_en":"Permanganate index","parameters":[{"name":"Zakres","range":"(0,70 – 10) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(0,70 – 10) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Indeks nadmanganianowy\nZakres (0,70 – 10) mg/l O2\nMetoda miareczkowa","reference":"PN-EN ISO 8467: 2001","norm_bases":["PN-EN ISO 8467: 2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda na pływalniach / basenach kąpielowych Indeks nadmanganianowy\nZakres (0,70 – 10) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467: 2001 Woda, Woda na plywalniach / basenach kapielowych Indeks nadmanganianowy\nZakres (0,70 – 10) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467: 2001","categories":["water"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water in swimming pools / bathing pools Permanganate index Titrimetric method Range PN-EN ISO 8467: 2001","methodology_zh":"高锰酸盐指数","parameters_zh":[{"name":"范围","range":"(0,70 – 10) mg/l O2"}],"search_zh":"水、游泳池/泳池水 高锰酸盐指数 滴定法 范围 PN-EN ISO 8467: 2001","technique_zh":"滴定法","test_object_zh":"水、游泳池/泳池水"},{"_id":"6a5dc9bbf1c10c8ce825df9d","lab_id":"69ad52a3de79e566650fb37a","country":"PL","accr_number":"AB 682","accr_body":"PCA","test_object":"Mleko i produkty mleczne, Lody na bazie substytutów mleka, Owoce i warzywa, przetwory owocowo-warzywne oraz warzywno-mięsne, Słodycze, wyroby cukiernicze i ciastkarskie, Mięso i produkty mięsne, Wyroby garmażeryjne, Ryby i przetwory rybne oraz owoce morza, Mięso i produkty drobiowe, Jaja i przetwory jajeczne, Suplementy diety, Kawa i herbata, Koncentraty spożywcze, Surowce i przetwory zielarskie, przyprawy, Preparaty dla niemowląt i dalszego żywienia niemowląt, Suszone zboża, owoce, orzechy, nasiona i warzywa, Wieloskładnikowa żywność lub składniki posiłków, Produkty zbożowo-mączne, Substytuty nabiału, Substytuty mięsa","test_object_en":"Milk and dairy products, Ice cream based on milk substitutes, Fruit and vegetables, fruit-vegetable and vegetable-meat products, Sweets, confectionery and pastry products, Meat and meat products, Delicatessen products, Fish and fish products and seafood, Poultry meat and poultry products, Eggs and egg products, Food supplements, Coffee and tea, Food concentrates, Herbal raw materials and products, spices, Infant formulae and follow-on formulae, Dried cereals, fruit, nuts, seeds and vegetables, Multi-ingredient food or meal components, Cereal and flour products, Dairy substitutes, Meat substitutes","methodology":"Obecność Salmonella spp. do 25 g lub 25 ml","methodology_en":"Presence of Salmonella spp. in up to 25 g or 25 ml","parameters":[],"parameters_en":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"technique_en":"Culture method with biochemical and serological confirmation","computed":[],"computed_en":[],"activity":"Obecność Salmonella spp. do 25 g lub 25 ml\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PN-EN ISO 6579-1:2017-04 | PN-EN ISO 6579-1:2017-04/A1:2020:09","norm_bases":["PN-EN ISO 6579-1:2017-04","PN-EN ISO 6579-1:2017-04/A1:2020:09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mleko i produkty mleczne, Lody na bazie substytutów mleka, Owoce i warzywa, przetwory owocowo-warzywne oraz warzywno-mięsne, Słodycze, wyroby cukiernicze i ciastkarskie, Mięso i produkty mięsne, Wyroby garmażeryjne, Ryby i przetwory rybne oraz owoce morza, Mięso i produkty drobiowe, Jaja i przetwory jajeczne, Suplementy diety, Kawa i herbata, Koncentraty spożywcze, Surowce i przetwory zielarskie, przyprawy, Preparaty dla niemowląt i dalszego żywienia niemowląt, Suszone zboża, owoce, orzechy, nasiona i warzywa, Wieloskładnikowa żywność lub składniki posiłków, Produkty zbożowo-mączne, Substytuty nabiału, Substytuty mięsa Obecność Salmonella spp. do 25 g lub 25 ml\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579-1:2017-04 | PN-EN ISO 6579-1:2017-04/A1:2020:09 Mleko i produkty mleczne, Lody na bazie substytutow mleka, Owoce i warzywa, przetwory owocowo-warzywne oraz warzywno-miesne, Slodycze, wyroby cukiernicze i ciastkarskie, Mieso i produkty miesne, Wyroby garmazeryjne, Ryby i przetwory rybne oraz owoce morza, Mieso i produkty drobiowe, Jaja i przetwory jajeczne, Suplementy diety, Kawa i herbata, Koncentraty spozywcze, Surowce i przetwory zielarskie, przyprawy, Preparaty dla niemowlat i dalszego zywienia niemowlat, Suszone zboza, owoce, orzechy, nasiona i warzywa, Wieloskladnikowa zywnosc lub skladniki posilkow, Produkty zbozowo-maczne, Substytuty nabialu, Substytuty miesa Obecnosc Salmonella spp. do 25 g lub 25 ml\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579-1:2017-04 | PN-EN ISO 6579-1:2017-04/A1:2020:09","categories":["food","microbiology","pharma"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Milk and dairy products, Ice cream based on milk substitutes, Fruit and vegetables, fruit-vegetable and vegetable-meat products, Sweets, confectionery and pastry products, Meat and meat products, Delicatessen products, Fish and fish products and seafood, Poultry meat and poultry products, Eggs and egg products, Food supplements, Coffee and tea, Food concentrates, Herbal raw materials and products, spices, Infant formulae and follow-on formulae, Dried cereals, fruit, nuts, seeds and vegetables, Multi-ingredient food or meal components, Cereal and flour products, Dairy substitutes, Meat substitutes Presence of Salmonella spp. in up to 25 g or 25 ml Culture method with biochemical and serological confirmation PN-EN ISO 6579-1:2017-04 | PN-EN ISO 6579-1:2017-04/A1:2020:09","search_zh":"培养法结合生化与血清学确认 PN-EN ISO 6579-1:2017-04 | PN-EN ISO 6579-1:2017-04/A1:2020:09","technique_zh":"培养法结合生化与血清学确认"},{"_id":"6a5dc9bbf1c10c8ce825df9e","lab_id":"69ad52a3de79e566650fb37a","country":"PL","accr_number":"AB 682","accr_body":"PCA","test_object":"Mleko i produkty mleczne, Owoce i warzywa, przetwory owocowo-warzywne oraz warzywno-mięsne, Słodycze, wyroby cukiernicze i ciastkarskie, Wyroby garmażeryjne","test_object_en":"Milk and dairy products, Fruit and vegetables, fruit-vegetable and vegetable-meat products, Sweets, confectionery and pastry products, Delicatessen products","methodology":"Liczba Listeria monocytogenes","methodology_en":"Listeria monocytogenes count","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda płytkowa (posiew powierzchniowy)"],"technique_en":"Plate method (spread plate)","computed":[],"computed_en":[],"activity":"Liczba Listeria monocytogenes\nMetoda płytkowa (posiew powierzchniowy)","reference":"PN-EN ISO 11290-2:2017-07","norm_bases":["PN-EN ISO 11290-2:2017-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mleko i produkty mleczne, Owoce i warzywa, przetwory owocowo-warzywne oraz warzywno-mięsne, Słodycze, wyroby cukiernicze i ciastkarskie, Wyroby garmażeryjne Liczba Listeria monocytogenes\nMetoda płytkowa (posiew powierzchniowy) PN-EN ISO 11290-2:2017-07 Mleko i produkty mleczne, Owoce i warzywa, przetwory owocowo-warzywne oraz warzywno-miesne, Slodycze, wyroby cukiernicze i ciastkarskie, Wyroby garmazeryjne Liczba Listeria monocytogenes\nMetoda plytkowa (posiew powierzchniowy) PN-EN ISO 11290-2:2017-07","categories":["food","microbiology"],"row_index":21,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Milk and dairy products, Fruit and vegetables, fruit-vegetable and vegetable-meat products, Sweets, confectionery and pastry products, Delicatessen products Listeria monocytogenes count Plate method (spread plate) PN-EN ISO 11290-2:2017-07","search_zh":"单核细胞增生李斯特氏菌计数 平板法（表面涂布） PN-EN ISO 11290-2:2017-07","technique_zh":"平板法（表面涂布）","methodology_zh":"单核细胞增生李斯特氏菌计数"},{"_id":"6a5dc9bbf1c10c8ce825df9f","lab_id":"69ad52a3de79e566650fb37a","country":"PL","accr_number":"AB 682","accr_body":"PCA","test_object":"Słodycze, wyroby cukiernicze i ciastkarskie, Wyroby garmażeryjne, Produkty zbożowo-mączne, Wieloskładnikowa żywność lub składniki posiłków, Substytuty nabiału, Substytuty mięsa, Suplementy diety","test_object_en":"Sweets, confectionery and pastry products, Delicatessen products, Cereal-flour products, Multi-ingredient foods or meal components, Dairy substitutes, Meat substitutes, Food supplements","methodology":"Liczba Bacillus cereus","methodology_en":"Bacillus cereus count","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda płytkowa (posiew powierzchniowy)"],"technique_en":"Plate method (spread plate)","computed":[],"computed_en":[],"activity":"Liczba Bacillus cereus\nMetoda płytkowa (posiew powierzchniowy)","reference":"PN-EN ISO 7932:2005 | PN-EN ISO 7932:2005/A1:2020-09 z wył. pkt. 9.5","norm_bases":["PN-EN ISO 7932:2005","PN-EN ISO 7932:2005/A1:2020-09 z wył. pkt. 9.5"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Słodycze, wyroby cukiernicze i ciastkarskie, Wyroby garmażeryjne, Produkty zbożowo-mączne, Wieloskładnikowa żywność lub składniki posiłków, Substytuty nabiału, Substytuty mięsa, Suplementy diety Liczba Bacillus cereus\nMetoda płytkowa (posiew powierzchniowy) PN-EN ISO 7932:2005 | PN-EN ISO 7932:2005/A1:2020-09 z wył. pkt. 9.5 Slodycze, wyroby cukiernicze i ciastkarskie, Wyroby garmazeryjne, Produkty zbozowo-maczne, Wieloskladnikowa zywnosc lub skladniki posilkow, Substytuty nabialu, Substytuty miesa, Suplementy diety Liczba Bacillus cereus\nMetoda plytkowa (posiew powierzchniowy) PN-EN ISO 7932:2005 | PN-EN ISO 7932:2005/A1:2020-09 z wyl. pkt. 9.5","categories":["food","pharma"],"row_index":22,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sweets, confectionery and pastry products, Delicatessen products, Cereal-flour products, Multi-ingredient foods or meal components, Dairy substitutes, Meat substitutes, Food supplements Bacillus cereus count Plate method (spread plate) PN-EN ISO 7932:2005 | PN-EN ISO 7932:2005/A1:2020-09 z wył. pkt. 9.5","search_zh":"蜡样芽孢杆菌数 平板法（表面涂布） PN-EN ISO 7932:2005 | PN-EN ISO 7932:2005/A1:2020-09 z wył. pkt. 9.5","technique_zh":"平板法（表面涂布）","methodology_zh":"蜡样芽孢杆菌数"},{"_id":"6a5dc9bbf1c10c8ce825dfa0","lab_id":"69ad52a3de79e566650fb37a","country":"PL","accr_number":"AB 682","accr_body":"PCA","test_object":"Mleko i produkty mleczne, Wieloskładnikowa żywność lub składniki posiłków, Słodycze, wyroby cukiernicze i ciastkarskie, Produkty zbożowo-mączne, Preparaty dla niemowląt i dalszego żywienia niemowląt, Wyroby garmażeryjne","test_object_en":"Milk and dairy products, Multi-ingredient food or meal components, Sweets, confectionery and pastry products, Cereal and flour products, Infant formulae and follow-on formulae, Delicatessen products","methodology":"Liczba Enterobacteriaceae","methodology_en":"Enterobacteriaceae count","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"technique_en":"Plate method (pour plate)","computed":[],"computed_en":[],"activity":"Liczba Enterobacteriaceae\nMetoda płytkowa (posiew wgłębny)","reference":"PN-ISO 21528-2:2017-08","norm_bases":["PN-ISO 21528-2:2017-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mleko i produkty mleczne, Wieloskładnikowa żywność lub składniki posiłków, Słodycze, wyroby cukiernicze i ciastkarskie, Produkty zbożowo-mączne, Preparaty dla niemowląt i dalszego żywienia niemowląt, Wyroby garmażeryjne Liczba Enterobacteriaceae\nMetoda płytkowa (posiew wgłębny) PN-ISO 21528-2:2017-08 Mleko i produkty mleczne, Wieloskladnikowa zywnosc lub skladniki posilkow, Slodycze, wyroby cukiernicze i ciastkarskie, Produkty zbozowo-maczne, Preparaty dla niemowlat i dalszego zywienia niemowlat, Wyroby garmazeryjne Liczba Enterobacteriaceae\nMetoda plytkowa (posiew wglebny) PN-ISO 21528-2:2017-08","categories":["food"],"row_index":23,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Milk and dairy products, Multi-ingredient food or meal components, Sweets, confectionery and pastry products, Cereal and flour products, Infant formulae and follow-on formulae, Delicatessen products Enterobacteriaceae count Plate method (pour plate) PN-ISO 21528-2:2017-08","methodology_zh":"肠杆菌科（Enterobacteriaceae）计数","search_zh":"肠杆菌科（Enterobacteriaceae）计数 平板法（倾注培养） PN-ISO 21528-2:2017-08","technique_zh":"平板法（倾注培养）"},{"_id":"6a5dc9bbf1c10c8ce825dfa1","lab_id":"69ad52a3de79e566650fb37a","country":"PL","accr_number":"AB 682","accr_body":"PCA","test_object":"Mleko i produkty mleczne, Mięso i produkty drobiowe, Wieloskładnikowa żywność lub składniki posiłków, Wyroby garmażeryjne, Produkty zbożowo-mączne","test_object_en":"Milk and dairy products, Poultry meat and poultry products, Multi-ingredient food or meal components, Delicatessen products, Cereal and flour products","methodology":"Liczba gronkowców koagulazo-dodatnich (Staphylococcus aureus i innych gatunków)","methodology_en":"Coagulase-positive staphylococci count (Staphylococcus aureus and other species)","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda płytkowa (posiew powierzchniowy)"],"technique_en":"Plate method (spread plate)","computed":[],"computed_en":[],"activity":"Liczba gronkowców koagulazo-dodatnich (Staphylococcus aureus i innych gatunków)\nMetoda płytkowa (posiew powierzchniowy)","reference":"PN-EN ISO 6888-1:2022-03/A1:2024-02","norm_bases":["PN-EN ISO 6888-1:2022-03/A1:2024-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mleko i produkty mleczne, Mięso i produkty drobiowe, Wieloskładnikowa żywność lub składniki posiłków, Wyroby garmażeryjne, Produkty zbożowo-mączne Liczba gronkowców koagulazo-dodatnich (Staphylococcus aureus i innych gatunków)\nMetoda płytkowa (posiew powierzchniowy) PN-EN ISO 6888-1:2022-03/A1:2024-02 Mleko i produkty mleczne, Mieso i produkty drobiowe, Wieloskladnikowa zywnosc lub skladniki posilkow, Wyroby garmazeryjne, Produkty zbozowo-maczne Liczba gronkowcow koagulazo-dodatnich (Staphylococcus aureus i innych gatunkow)\nMetoda plytkowa (posiew powierzchniowy) PN-EN ISO 6888-1:2022-03/A1:2024-02","categories":["food"],"row_index":24,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Milk and dairy products, Poultry meat and poultry products, Multi-ingredient food or meal components, Delicatessen products, Cereal and flour products Coagulase-positive staphylococci count (Staphylococcus aureus and other species) Plate method (spread plate) PN-EN ISO 6888-1:2022-03/A1:2024-02","search_zh":"凝固酶阳性葡萄球菌数（金黄色葡萄球菌及其他菌种） 平板法（表面涂布） PN-EN ISO 6888-1:2022-03/A1:2024-02","technique_zh":"平板法（表面涂布）","methodology_zh":"凝固酶阳性葡萄球菌数（金黄色葡萄球菌及其他菌种）"},{"_id":"6a5dc9bbf1c10c8ce825dfa2","lab_id":"69ad52a3de79e566650fb37a","country":"PL","accr_number":"AB 682","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Liczba bakterii z rodzaju Legionella","methodology_en":"Count of bacteria of the genus Legionella","parameters":[{"name":"Matryca A Procedura 7 (pożywka GVPC)"}],"parameters_en":[{"name":"Matrix A Procedure 7 (medium GVPC)"}],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba bakterii z rodzaju Legionella\nMatryca A Procedura 7 (pożywka GVPC)\nMetoda filtracji membranowej","reference":"PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08/Ap1:2019-12","norm_bases":["PN-EN ISO 11731:2017-08","PN-EN ISO 11731:2017-08/Ap1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Liczba bakterii z rodzaju Legionella\nMatryca A Procedura 7 (pożywka GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08/Ap1:2019-12 Woda, Woda do spozycia przez ludzi Liczba bakterii z rodzaju Legionella\nMatryca A Procedura 7 (pozywka GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08/Ap1:2019-12","categories":["microbiology","water"],"row_index":25,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Count of bacteria of the genus Legionella Membrane filtration method Matrix A Procedure 7 (medium GVPC) PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08/Ap1:2019-12","search_zh":"水、生活饮用水 军团菌属细菌计数 膜过滤法 PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08/Ap1:2019-12","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水","methodology_zh":"军团菌属细菌计数"},{"_id":"6a5dc9bbf1c10c8ce825dfa3","lab_id":"69ad52a3de79e566650fb37a","country":"PL","accr_number":"AB 682","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Liczba bakterii grupy coli","methodology_en":"Coliform bacteria count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda, Woda do spozycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":26,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04","methodology_zh":"大肠菌群计数","search_zh":"水、生活饮用水 大肠菌群计数 膜过滤法 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9bbf1c10c8ce825dfa4","lab_id":"69ad52a3de79e566650fb37a","country":"PL","accr_number":"AB 682","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Liczba Escherichia coli","methodology_en":"Escherichia coli count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda, Woda do spozycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":27,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"水、生活饮用水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9bbf1c10c8ce825dfa5","lab_id":"69ad52a3de79e566650fb37a","country":"PL","accr_number":"AB 682","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Ogólna liczba mikroorganizmów w temp. 22°C","methodology_en":"Total viable count at 22°C","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"technique_en":"Plate method (pour plate)","computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w temp. 22°C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w temp. 22°C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda, Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w temp. 22°C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":28,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Total viable count at 22°C Plate method (pour plate) PN-EN ISO 6222:2004","methodology_zh":"22°C 微生物总数","search_zh":"水、生活饮用水 22°C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9bbf1c10c8ce825dfa6","lab_id":"69ad52a3de79e566650fb37a","country":"PL","accr_number":"AB 682","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Ogólna liczba mikroorganizmów w temp. 36°C","methodology_en":"Total viable count at 36°C","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"technique_en":"Plate method (pour plate)","computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w temp. 36°C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w temp. 36°C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda, Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w temp. 36°C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":29,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Total viable count at 36°C Plate method (pour plate) PN-EN ISO 6222:2004","search_zh":"水、生活饮用水 36°C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水、生活饮用水","methodology_zh":"36°C 微生物总数"},{"_id":"6a5dc9bbf1c10c8ce825dfa7","lab_id":"69ad52a3de79e566650fb37a","country":"PL","accr_number":"AB 682","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Liczba enterokoków kałowych","methodology_en":"Intestinal enterococci count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba enterokoków kałowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Liczba enterokoków kałowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda, Woda do spozycia przez ludzi Liczba enterokokow kalowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":30,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004","methodology_zh":"粪肠球菌计数","search_zh":"水、生活饮用水 粪肠球菌计数 膜过滤法 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9bbf1c10c8ce825dfa8","lab_id":"69ad52a3de79e566650fb37a","country":"PL","accr_number":"AB 682","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Liczba Clostridium perfringens (ze sporami)","methodology_en":"Clostridium perfringens count (with spores)","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Clostridium perfringens (ze sporami)\nMetoda filtracji membranowej","reference":"PN-EN ISO 14189:2016-10","norm_bases":["PN-EN ISO 14189:2016-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Liczba Clostridium perfringens (ze sporami)\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10 Woda, Woda do spozycia przez ludzi Liczba Clostridium perfringens (ze sporami)\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10","categories":["water"],"row_index":31,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Clostridium perfringens count (with spores) Membrane filtration method PN-EN ISO 14189:2016-10","search_zh":"水、生活饮用水 膜过滤法 PN-EN ISO 14189:2016-10","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9bbf1c10c8ce825dfa9","lab_id":"69ad52a3de79e566650fb37a","country":"PL","accr_number":"AB 682","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Liczba Pseudomonas aeruginosa","methodology_en":"Pseudomonas aeruginosa count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009 Woda na plywalniach Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water"],"row_index":32,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009","methodology_zh":"铜绿假单胞菌计数","search_zh":"游泳池水 铜绿假单胞菌计数 膜过滤法 PN-EN ISO 16266:2009","technique_zh":"膜过滤法","test_object_zh":"游泳池水"},{"_id":"6a5dc9bbf1c10c8ce825dfaa","lab_id":"69ad52a3de79e566650fb37a","country":"PL","accr_number":"AB 682","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Liczba Escherichia coli","methodology_en":"Escherichia coli count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12+A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12+A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12+A1:2017-04 Woda na plywalniach Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12+A1:2017-04","categories":["water","microbiology"],"row_index":33,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12+A1:2017-04","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"游泳池水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PN-EN ISO 9308-1:2014-12+A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"游泳池水"},{"_id":"6a5dc9bbf1c10c8ce825dfab","lab_id":"69ad52a3de79e566650fb37a","country":"PL","accr_number":"AB 682","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Ogólna liczba mikroorganizmów w temp. 36°C","methodology_en":"Total viable count at 36°C","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"technique_en":"Plate method (pour plate)","computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w temp. 36°C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Ogólna liczba mikroorganizmów w temp. 36°C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda na plywalniach Ogolna liczba mikroorganizmow w temp. 36°C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":34,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water Total viable count at 36°C Plate method (pour plate) PN-EN ISO 6222:2004","search_zh":"游泳池水 36°C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"游泳池水","methodology_zh":"36°C 微生物总数"},{"_id":"6a5dc9bbf1c10c8ce825dfac","lab_id":"69ad52a3de79e566650fb37a","country":"PL","accr_number":"AB 682","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Liczba bakterii z rodzaju Legionella","methodology_en":"Count of bacteria of the genus Legionella","parameters":[{"name":"Matryca A Procedura 7 (pożywka GVPC)"}],"parameters_en":[{"name":"Matrix A Procedure 7 (medium GVPC)"}],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba bakterii z rodzaju Legionella\nMatryca A Procedura 7 (pożywka GVPC)\nMetoda filtracji membranowej","reference":"PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08/Ap1:2019-12","norm_bases":["PN-EN ISO 11731:2017-08","PN-EN ISO 11731:2017-08/Ap1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Liczba bakterii z rodzaju Legionella\nMatryca A Procedura 7 (pożywka GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08/Ap1:2019-12 Woda na plywalniach Liczba bakterii z rodzaju Legionella\nMatryca A Procedura 7 (pozywka GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08/Ap1:2019-12","categories":["microbiology","water"],"row_index":35,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water Count of bacteria of the genus Legionella Membrane filtration method Matrix A Procedure 7 (medium GVPC) PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08/Ap1:2019-12","search_zh":"游泳池水 军团菌属细菌计数 膜过滤法 PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08/Ap1:2019-12","technique_zh":"膜过滤法","test_object_zh":"游泳池水","methodology_zh":"军团菌属细菌计数"},{"_id":"6a5dc9bbf1c10c8ce825dfad","lab_id":"69ad52a3de79e566650fb37a","country":"PL","accr_number":"AB 682","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Stężenie rtęci","methodology_en":"Mercury concentration","parameters":[{"name":"Zakres","range":"(0,0003 – 0,002) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,0003 – 0,002) mg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)"],"technique_en":"Cold vapour atomic absorption spectrometry (CVAAS)","computed":[],"computed_en":[],"activity":"Stężenie rtęci\nZakres (0,0003 – 0,002) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"PN-EN 1483:2007","norm_bases":["PN-EN 1483:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie rtęci\nZakres (0,0003 – 0,002) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN 1483:2007 Woda, Woda do spozycia przez ludzi Stezenie rteci\nZakres (0,0003 – 0,002) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN 1483:2007","categories":["water"],"row_index":36,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Mercury concentration Cold vapour atomic absorption spectrometry (CVAAS) Range PN-EN 1483:2007","methodology_zh":"汞浓度","parameters_zh":[{"name":"范围","range":"(0,0003 – 0,002) mg/l"}],"search_zh":"水、生活饮用水 汞浓度 冷蒸气原子吸收光谱法（CVAAS） 范围 PN-EN 1483:2007","technique_zh":"冷蒸气原子吸收光谱法（CVAAS）","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9bbf1c10c8ce825dfae","lab_id":"69ad52a3de79e566650fb37a","country":"PL","accr_number":"AB 682","accr_body":"PCA","test_object":"Kał, Wymaz z odbytu, Szczepy bakteryjne","test_object_en":"Faeces, Rectal swab, Bacterial strains","methodology":"Obecność pałeczek, Salmonella spp. i Shigella spp.","methodology_en":"Presence of rods, Salmonella spp. and Shigella spp.","parameters":[],"parameters_en":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"technique_en":"Culture method with biochemical and serological confirmation","computed":[],"computed_en":[],"activity":"Obecność pałeczek, Salmonella spp. i Shigella spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PB-01 wydanie 08 z dnia 01.12.2021 r.","norm_bases":["PB-01 wydanie 08 z dnia 01.12.2021 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kał, Wymaz z odbytu, Szczepy bakteryjne Obecność pałeczek, Salmonella spp. i Shigella spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB-01 wydanie 08 z dnia 01.12.2021 r. Kal, Wymaz z odbytu, Szczepy bakteryjne Obecnosc paleczek, Salmonella spp. i Shigella spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB-01 wydanie 08 z dnia 01.12.2021 r.","categories":["microbiology"],"row_index":37,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Faeces, Rectal swab, Bacterial strains Presence of rods, Salmonella spp. and Shigella spp. Culture method with biochemical and serological confirmation PB-01 wydanie 08 z dnia 01.12.2021 r.","search_zh":"培养法结合生化与血清学确认 PB-01 wydanie 08 z dnia 01.12.2021 r.","technique_zh":"培养法结合生化与血清学确认"},{"_id":"6a5dc9bbf1c10c8ce825dfaf","lab_id":"69ad52a3de79e566650fb37a","country":"PL","accr_number":"AB 682","accr_body":"PCA","test_object":"Kał, Wymaz z odbytu, Szczepy bakteryjne","test_object_en":"Faeces, Rectal swab, Bacterial strains","methodology":"Obecność pałeczek:","methodology_en":"Presence of rods:","parameters":[{"name":"Salmonella Enteritidis"},{"name":"Salmonella Typhimurium"}],"parameters_en":[{"name":"Salmonella Enteritidis"},{"name":"Salmonella Typhimurium"}],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"technique_en":"Culture method with biochemical and serological confirmation","computed":[],"computed_en":[],"activity":"Obecność pałeczek:\nZakres:\nSalmonella Enteritidis\nSalmonella Typhimurium\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PB-01 wydanie 08 z dnia 01.12.2021 r.","norm_bases":["PB-01 wydanie 08 z dnia 01.12.2021 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kał, Wymaz z odbytu, Szczepy bakteryjne Obecność pałeczek:\nZakres:\nSalmonella Enteritidis\nSalmonella Typhimurium\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB-01 wydanie 08 z dnia 01.12.2021 r. Kal, Wymaz z odbytu, Szczepy bakteryjne Obecnosc paleczek:\nZakres:\nSalmonella Enteritidis\nSalmonella Typhimurium\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB-01 wydanie 08 z dnia 01.12.2021 r.","categories":["microbiology"],"row_index":38,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Faeces, Rectal swab, Bacterial strains Presence of rods: Culture method with biochemical and serological confirmation Salmonella Enteritidis Salmonella Typhimurium PB-01 wydanie 08 z dnia 01.12.2021 r.","search_zh":"培养法结合生化与血清学确认 PB-01 wydanie 08 z dnia 01.12.2021 r.","technique_zh":"培养法结合生化与血清学确认"},{"_id":"6a5dc9bbf1c10c8ce825dfb0","lab_id":"69ad52a3de79e566650fb37a","country":"PL","accr_number":"AB 682","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Woda na pływalniach","test_object_en":"Water, Water intended for human consumption, Swimming pool water","methodology":"Stężenie trihalogenometanów (THM):","methodology_en":"Trihalomethane (THM) concentration:","parameters":[{"name":"Trichlorometan","range":"(0,002 – 0,120) mg/l"},{"name":"Tribromometan","range":"(0,002 – 0,120) mg/l"},{"name":"Bromodichlorometan","range":"(0,002 – 0,120) mg/l"},{"name":"Dibromochlorometan","range":"(0,002 – 0,120) mg/l"},{"name":"Σ THM (z obliczeń)"}],"parameters_en":[{"name":"Trichloromethane","range":"(0,002 – 0,120) mg/l"},{"name":"Tribromomethane","range":"(0,002 – 0,120) mg/l"},{"name":"Bromodichloromethane","range":"(0,002 – 0,120) mg/l"},{"name":"Dibromochloromethane","range":"(0,002 – 0,120) mg/l"},{"name":"Σ THM (calculated)"}],"technique":"Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","techniques":["Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)"],"technique_en":"Gas chromatography with electron capture detection (GC-ECD)","computed":[],"computed_en":[],"activity":"Stężenie trihalogenometanów (THM):\nZakres:\nTrichlorometan (0,002 – 0,120) mg/l\nTribromometan (0,002 – 0,120) mg/l\nBromodichlorometan (0,002 – 0,120) mg/l\nDibromochlorometan (0,002 – 0,120) mg/l\nΣ THM (z obliczeń)\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","reference":"PN-EN ISO 10301:2002 z wył. pkt. 2.6 IT-118 wydanie 04 z dnia 07.11.2022 r.","norm_bases":["PN-EN ISO 10301:2002 z wył. pkt. 2.6 IT-118 wydanie 04 z dnia 07.11.2022 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi, Woda na pływalniach Stężenie trihalogenometanów (THM):\nZakres:\nTrichlorometan (0,002 – 0,120) mg/l\nTribromometan (0,002 – 0,120) mg/l\nBromodichlorometan (0,002 – 0,120) mg/l\nDibromochlorometan (0,002 – 0,120) mg/l\nΣ THM (z obliczeń)\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) PN-EN ISO 10301:2002 z wył. pkt. 2.6 IT-118 wydanie 04 z dnia 07.11.2022 r. Woda, Woda do spozycia przez ludzi, Woda na plywalniach Stezenie trihalogenometanow (THM):\nZakres:\nTrichlorometan (0,002 – 0,120) mg/l\nTribromometan (0,002 – 0,120) mg/l\nBromodichlorometan (0,002 – 0,120) mg/l\nDibromochlorometan (0,002 – 0,120) mg/l\nΣ THM (z obliczen)\nMetoda chromatografii gazowej z detekcja wychwytu elektronow (GC-ECD) PN-EN ISO 10301:2002 z wyl. pkt. 2.6 IT-118 wydanie 04 z dnia 07.11.2022 r.","categories":["water"],"row_index":39,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption, Swimming pool water Trihalomethane (THM) concentration: Gas chromatography with electron capture detection (GC-ECD) Trichloromethane Tribromomethane Bromodichloromethane Dibromochloromethane Σ THM (calculated) PN-EN ISO 10301:2002 z wył. pkt. 2.6 IT-118 wydanie 04 z dnia 07.11.2022 r.","search_zh":"水、生活饮用水、游泳池水 气相色谱-电子捕获检测法（GC-ECD） 三氯甲烷 三溴甲烷 一溴二氯甲烷 二溴一氯甲烷 PN-EN ISO 10301:2002 z wył. pkt. 2.6 IT-118 wydanie 04 z dnia 07.11.2022 r.","technique_zh":"气相色谱-电子捕获检测法（GC-ECD）","test_object_zh":"水、生活饮用水、游泳池水","parameters_zh":[{"name":"三氯甲烷","range":"(0,002 – 0,120) mg/l"},{"name":"三溴甲烷","range":"(0,002 – 0,120) mg/l"},{"name":"一溴二氯甲烷","range":"(0,002 – 0,120) mg/l"},{"name":"二溴一氯甲烷","range":"(0,002 – 0,120) mg/l"},{"name":"Σ THM (z obliczeń)"}]},{"_id":"6a5dc9bbf1c10c8ce825dfb1","lab_id":"69ad52a3de79e566650fb37a","country":"PL","accr_number":"AB 682","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Woda na pływalniach","test_object_en":"Water, Water intended for human consumption, Swimming pool water","methodology":"Stężenie pierwiastków","methodology_en":"Element concentration","parameters":[{"name":"glin","range":"(0,030 – 4,00) mg/l"}],"parameters_en":[{"name":"aluminium","range":"(0,030 – 4,00) mg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)"],"technique_en":"Electrothermal atomization atomic absorption spectrometry (ETAAS)","computed":[],"computed_en":[],"activity":"Stężenie pierwiastków\nglin (0,030 – 4,00) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","reference":"PN-EN ISO 15586:2005","norm_bases":["PN-EN ISO 15586:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi, Woda na pływalniach Stężenie pierwiastków\nglin (0,030 – 4,00) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS) PN-EN ISO 15586:2005 Woda, Woda do spozycia przez ludzi, Woda na plywalniach Stezenie pierwiastkow\nglin (0,030 – 4,00) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacja elektrotermiczna (ETAAS) PN-EN ISO 15586:2005","categories":["water"],"row_index":40,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption, Swimming pool water Element concentration Electrothermal atomization atomic absorption spectrometry (ETAAS) aluminium PN-EN ISO 15586:2005","methodology_zh":"元素浓度","search_zh":"水、生活饮用水、游泳池水 元素浓度 电热原子化原子吸收光谱法（ETAAS） 铝 PN-EN ISO 15586:2005","technique_zh":"电热原子化原子吸收光谱法（ETAAS）","parameters_zh":[{"name":"铝","range":"(0,030 – 4,00) mg/l"}],"test_object_zh":"水、生活饮用水、游泳池水"},{"_id":"6a5dc9bbf1c10c8ce825dfb2","lab_id":"69ad52a3de79e566650fb37a","country":"PL","accr_number":"AB 682","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Stężenie łatwolotnych chlorowcowych pochodnych węglowodorów alifatycznych","methodology_en":"Concentration of highly volatile aliphatic halogenated hydrocarbon derivatives","parameters":[{"name":"Trichloroeten","range":"(0,5 - 12) μg/l"},{"name":"Tetrachloroeten","range":"(0,5 - 12) μg/l"},{"name":"1,2-Dichloroetan","range":"(0,5 - 12) μg/l"},{"name":"Tetrachlorometan","range":"(0,5 - 12) μg/l"},{"name":"Σ Trichloroeten i Tetrachloroeten (z obliczeń)"}],"parameters_en":[{"name":"Trichloroethene","range":"(0,5 - 12) μg/l"},{"name":"Tetrachloroethene","range":"(0,5 - 12) μg/l"},{"name":"1,2-Dichloroethane","range":"(0,5 - 12) μg/l"},{"name":"Tetrachloromethane","range":"(0,5 - 12) μg/l"},{"name":"Σ Trichloroethene and Tetrachloroethene (calculated)"}],"technique":"Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","techniques":["Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)"],"technique_en":"Gas chromatography with electron capture detection (GC-ECD)","computed":[],"computed_en":[],"activity":"Stężenie łatwolotnych chlorowcowych pochodnych węglowodorów alifatycznych\nZakres:\nTrichloroeten (0,5 - 12) μg/l\nTetrachloroeten (0,5 - 12) μg/l\n1,2-Dichloroetan (0,5 - 12) μg/l\nTetrachlorometan (0,5 - 12) μg/l\nΣ Trichloroeten i Tetrachloroeten (z obliczeń)\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","reference":"PN-EN ISO 10301:2002 z wył. pkt. 2.6 IT-119 wydanie 04 z dnia 07.11.2022 r.","norm_bases":["PN-EN ISO 10301:2002 z wył. pkt. 2.6 IT-119 wydanie 04 z dnia 07.11.2022 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie łatwolotnych chlorowcowych pochodnych węglowodorów alifatycznych\nZakres:\nTrichloroeten (0,5 - 12) μg/l\nTetrachloroeten (0,5 - 12) μg/l\n1,2-Dichloroetan (0,5 - 12) μg/l\nTetrachlorometan (0,5 - 12) μg/l\nΣ Trichloroeten i Tetrachloroeten (z obliczeń)\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) PN-EN ISO 10301:2002 z wył. pkt. 2.6 IT-119 wydanie 04 z dnia 07.11.2022 r. Woda, Woda do spozycia przez ludzi Stezenie latwolotnych chlorowcowych pochodnych weglowodorow alifatycznych\nZakres:\nTrichloroeten (0,5 - 12) μg/l\nTetrachloroeten (0,5 - 12) μg/l\n1,2-Dichloroetan (0,5 - 12) μg/l\nTetrachlorometan (0,5 - 12) μg/l\nΣ Trichloroeten i Tetrachloroeten (z obliczen)\nMetoda chromatografii gazowej z detekcja wychwytu elektronow (GC-ECD) PN-EN ISO 10301:2002 z wyl. pkt. 2.6 IT-119 wydanie 04 z dnia 07.11.2022 r.","categories":["water"],"row_index":41,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Concentration of highly volatile aliphatic halogenated hydrocarbon derivatives Gas chromatography with electron capture detection (GC-ECD) Trichloroethene Tetrachloroethene 1,2-Dichloroethane Tetrachloromethane Σ Trichloroethene and Tetrachloroethene (calculated) PN-EN ISO 10301:2002 z wył. pkt. 2.6 IT-119 wydanie 04 z dnia 07.11.2022 r.","search_zh":"水、生活饮用水 气相色谱-电子捕获检测法（GC-ECD） 三氯乙烯 四氯乙烯 四氯化碳 PN-EN ISO 10301:2002 z wył. pkt. 2.6 IT-119 wydanie 04 z dnia 07.11.2022 r.","technique_zh":"气相色谱-电子捕获检测法（GC-ECD）","test_object_zh":"水、生活饮用水","parameters_zh":[{"name":"三氯乙烯","range":"(0,5 - 12) μg/l"},{"name":"四氯乙烯","range":"(0,5 - 12) μg/l"},{"name":"1,2-Dichloroetan","range":"(0,5 - 12) μg/l"},{"name":"四氯化碳","range":"(0,5 - 12) μg/l"},{"name":"Σ Trichloroeten i Tetrachloroeten (z obliczeń)"}]},{"_id":"6a5dc9bbf1c10c8ce825dfb3","lab_id":"69ad52a3de79e566650fb37a","country":"PL","accr_number":"AB 682","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Stężenie arsenu","methodology_en":"Arsenic concentration","parameters":[{"name":"Zakres","range":"(0,001 – 0,020) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,001 – 0,020) mg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem wodorków (HGAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem wodorków (HGAAS)"],"technique_en":"Hydride generation atomic absorption spectrometry (HGAAS)","computed":[],"computed_en":[],"activity":"Stężenie arsenu\nZakres (0,001 – 0,020) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem wodorków (HGAAS)","reference":"PN-EN ISO 11969:1999","norm_bases":["PN-EN ISO 11969:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie arsenu\nZakres (0,001 – 0,020) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem wodorków (HGAAS) PN-EN ISO 11969:1999 Woda, Woda do spozycia przez ludzi Stezenie arsenu\nZakres (0,001 – 0,020) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem wodorkow (HGAAS) PN-EN ISO 11969:1999","categories":["water"],"row_index":42,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Arsenic concentration Hydride generation atomic absorption spectrometry (HGAAS) Range PN-EN ISO 11969:1999","parameters_zh":[{"name":"范围","range":"(0,001 – 0,020) mg/l"}],"search_zh":"水、生活饮用水 砷浓度 氢化物发生原子吸收光谱法（HGAAS） 范围 PN-EN ISO 11969:1999","test_object_zh":"水、生活饮用水","technique_zh":"氢化物发生原子吸收光谱法（HGAAS）","methodology_zh":"砷浓度"},{"_id":"6a5dc9bbf1c10c8ce825dfb4","lab_id":"69ad52a3de79e566650fb37a","country":"PL","accr_number":"AB 682","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Stężenie pierwiastków","methodology_en":"Element concentration","parameters":[{"name":"mangan","range":"(0,003 – 2,00) mg/l"},{"name":"kadm","range":"(0,001 – 0,010) mg/l"},{"name":"ołów","range":"(0,002 – 0,020) mg/l"},{"name":"nikiel","range":"(0,005 – 0,050) mg/l"},{"name":"miedź","range":"(0,005 – 4,0) mg/l"},{"name":"antymon","range":"(0,002 – 0,010) mg/l"},{"name":"selen","range":"(0,002 – 0,020) mg/l"},{"name":"chrom ogólny","range":"(0,002 – 0,060) mg/l"},{"name":"arsen","range":"(0,002 - 0,050) mg/l"}],"parameters_en":[{"name":"manganese","range":"(0,003 – 2,00) mg/l"},{"name":"cadmium","range":"(0,001 – 0,010) mg/l"},{"name":"lead","range":"(0,002 – 0,020) mg/l"},{"name":"nickel","range":"(0,005 – 0,050) mg/l"},{"name":"copper","range":"(0,005 – 4,0) mg/l"},{"name":"antimony","range":"(0,002 – 0,010) mg/l"},{"name":"selenium","range":"(0,002 – 0,020) mg/l"},{"name":"total chromium","range":"(0,002 – 0,060) mg/l"},{"name":"arsenic","range":"(0,002 - 0,050) mg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)"],"technique_en":"Electrothermal atomization atomic absorption spectrometry (ETAAS)","computed":[],"computed_en":[],"activity":"Stężenie pierwiastków\nZakres:\nmangan (0,003 – 2,00) mg/l\nkadm (0,001 – 0,010) mg/l\nołów (0,002 – 0,020) mg/l\nnikiel (0,005 – 0,050) mg/l\nmiedź (0,005 – 4,0) mg/l\nantymon (0,002 – 0,010) mg/l\nselen (0,002 – 0,020) mg/l\nchrom ogólny (0,002 – 0,060) mg/l\narsen (0,002 - 0,050) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","reference":"PN-EN ISO 15586:2005","norm_bases":["PN-EN ISO 15586:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie pierwiastków\nZakres:\nmangan (0,003 – 2,00) mg/l\nkadm (0,001 – 0,010) mg/l\nołów (0,002 – 0,020) mg/l\nnikiel (0,005 – 0,050) mg/l\nmiedź (0,005 – 4,0) mg/l\nantymon (0,002 – 0,010) mg/l\nselen (0,002 – 0,020) mg/l\nchrom ogólny (0,002 – 0,060) mg/l\narsen (0,002 - 0,050) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS) PN-EN ISO 15586:2005 Woda, Woda do spozycia przez ludzi Stezenie pierwiastkow\nZakres:\nmangan (0,003 – 2,00) mg/l\nkadm (0,001 – 0,010) mg/l\nolow (0,002 – 0,020) mg/l\nnikiel (0,005 – 0,050) mg/l\nmiedz (0,005 – 4,0) mg/l\nantymon (0,002 – 0,010) mg/l\nselen (0,002 – 0,020) mg/l\nchrom ogolny (0,002 – 0,060) mg/l\narsen (0,002 - 0,050) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacja elektrotermiczna (ETAAS) PN-EN ISO 15586:2005","categories":["water","materials"],"row_index":43,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Element concentration Electrothermal atomization atomic absorption spectrometry (ETAAS) manganese cadmium lead nickel copper antimony selenium total chromium arsenic PN-EN ISO 15586:2005","methodology_zh":"元素浓度","parameters_zh":[{"name":"锰","range":"(0,003 – 2,00) mg/l"},{"name":"镉","range":"(0,001 – 0,010) mg/l"},{"name":"铅","range":"(0,002 – 0,020) mg/l"},{"name":"镍","range":"(0,005 – 0,050) mg/l"},{"name":"铜","range":"(0,005 – 4,0) mg/l"},{"name":"锑","range":"(0,002 – 0,010) mg/l"},{"name":"硒","range":"(0,002 – 0,020) mg/l"},{"name":"总铬","range":"(0,002 – 0,060) mg/l"},{"name":"砷","range":"(0,002 - 0,050) mg/l"}],"search_zh":"水、生活饮用水 元素浓度 电热原子化原子吸收光谱法（ETAAS） 锰 镉 铅 镍 铜 锑 硒 总铬 砷 PN-EN ISO 15586:2005","technique_zh":"电热原子化原子吸收光谱法（ETAAS）","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9bbf1c10c8ce825dfb5","lab_id":"69ad52a3de79e566650fb37a","country":"PL","accr_number":"AB 682","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Stężenie pierwiastków","methodology_en":"Element concentration","parameters":[{"name":"sód","range":"(1 – 300) mg/l"},{"name":"potas","range":"(1 – 30) mg/l"}],"parameters_en":[{"name":"sodium","range":"(1 – 300) mg/l"},{"name":"potassium","range":"(1 – 30) mg/l"}],"technique":"Metoda płomieniowej emisyjnej spektrometrii atomowej (FAES)","techniques":["Metoda płomieniowej emisyjnej spektrometrii atomowej (FAES)"],"technique_en":"Flame atomic emission spectrometry (FAES)","computed":[],"computed_en":[],"activity":"Stężenie pierwiastków\nZakres:\nsód (1 – 300) mg/l\npotas (1 – 30) mg/l\nMetoda płomieniowej emisyjnej spektrometrii atomowej (FAES)","reference":"PN-ISO 9964-3:1994","norm_bases":["PN-ISO 9964-3:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie pierwiastków\nZakres:\nsód (1 – 300) mg/l\npotas (1 – 30) mg/l\nMetoda płomieniowej emisyjnej spektrometrii atomowej (FAES) PN-ISO 9964-3:1994 Woda, Woda do spozycia przez ludzi Stezenie pierwiastkow\nZakres:\nsod (1 – 300) mg/l\npotas (1 – 30) mg/l\nMetoda plomieniowej emisyjnej spektrometrii atomowej (FAES) PN-ISO 9964-3:1994","categories":["water"],"row_index":44,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Element concentration Flame atomic emission spectrometry (FAES) sodium potassium PN-ISO 9964-3:1994","methodology_zh":"元素浓度","search_zh":"水、生活饮用水 元素浓度 火焰原子发射光谱法（FAES） 钠 钾 PN-ISO 9964-3:1994","test_object_zh":"水、生活饮用水","parameters_zh":[{"name":"钠","range":"(1 – 300) mg/l"},{"name":"钾","range":"(1 – 30) mg/l"}],"technique_zh":"火焰原子发射光谱法（FAES）"},{"_id":"6a5dc9bbf1c10c8ce825dfb6","lab_id":"69ad52a3de79e566650fb37a","country":"PL","accr_number":"AB 682","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Stężenie pierwiastków","methodology_en":"Element concentration","parameters":[{"name":"mangan","range":"(0,015 − 4,0) mg/l"},{"name":"miedź","range":"(0,025 – 4,0) mg/l"},{"name":"cynk","range":"(0,025 – 5,0) mg/l"},{"name":"żelazo ogólne","range":"(0,050 – 10,0) mg/l"}],"parameters_en":[{"name":"manganese","range":"(0,015 − 4,0) mg/l"},{"name":"copper","range":"(0,025 – 4,0) mg/l"},{"name":"zinc","range":"(0,025 – 5,0) mg/l"},{"name":"total iron","range":"(0,050 – 10,0) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"technique_en":"Flame atomic absorption spectrometry (FAAS)","computed":[],"computed_en":[],"activity":"Stężenie pierwiastków\nZakres:\nmangan (0,015 − 4,0) mg/l\nmiedź (0,025 – 4,0) mg/l\ncynk (0,025 – 5,0) mg/l\nżelazo ogólne (0,050 – 10,0) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 8288:2002","norm_bases":["PN-ISO 8288:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie pierwiastków\nZakres:\nmangan (0,015 − 4,0) mg/l\nmiedź (0,025 – 4,0) mg/l\ncynk (0,025 – 5,0) mg/l\nżelazo ogólne (0,050 – 10,0) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 Woda, Woda do spozycia przez ludzi Stezenie pierwiastkow\nZakres:\nmangan (0,015 − 4,0) mg/l\nmiedz (0,025 – 4,0) mg/l\ncynk (0,025 – 5,0) mg/l\nzelazo ogolne (0,050 – 10,0) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002","categories":["water","materials"],"row_index":45,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Element concentration Flame atomic absorption spectrometry (FAAS) manganese copper zinc total iron PN-ISO 8288:2002","methodology_zh":"元素浓度","parameters_zh":[{"name":"锰","range":"(0,015 − 4,0) mg/l"},{"name":"铜","range":"(0,025 – 4,0) mg/l"},{"name":"锌","range":"(0,025 – 5,0) mg/l"},{"name":"żelazo ogólne","range":"(0,050 – 10,0) mg/l"}],"search_zh":"水、生活饮用水 元素浓度 火焰原子吸收光谱法（FAAS） 锰 铜 锌 PN-ISO 8288:2002","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9bbf1c10c8ce825dfb7","lab_id":"69ad52a3de79e566650fb37a","country":"PL","accr_number":"AB 682","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Stężenie rtęci","methodology_en":"Mercury concentration","parameters":[{"name":"Zakres","range":"(0,0003 – 0,0020) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,0003 – 0,0020) mg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","techniques":["Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji"],"technique_en":"Atomic absorption spectrometry with amalgamation technique","computed":[],"computed_en":[],"activity":"Stężenie rtęci\nZakres (0,0003 – 0,0020) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","reference":"PB-021 wyd. 2 z dnia 11.10.2023 r.","norm_bases":["PB-021 wyd. 2 z dnia 11.10.2023 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie rtęci\nZakres (0,0003 – 0,0020) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji PB-021 wyd. 2 z dnia 11.10.2023 r. Woda, Woda do spozycia przez ludzi Stezenie rteci\nZakres (0,0003 – 0,0020) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z technika amalgamacji PB-021 wyd. 2 z dnia 11.10.2023 r.","categories":["water"],"row_index":46,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Mercury concentration Atomic absorption spectrometry with amalgamation technique Range PB-021 wyd. 2 z dnia 11.10.2023 r.","methodology_zh":"汞浓度","parameters_zh":[{"name":"范围","range":"(0,0003 – 0,0020) mg/l"}],"search_zh":"水、生活饮用水 汞浓度 原子吸收光谱法（汞齐化技术） 范围 PB-021 wyd. 2 z dnia 11.10.2023 r.","technique_zh":"原子吸收光谱法（汞齐化技术）","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9bbf1c10c8ce825dfb8","lab_id":"69ad52a3de79e566650fb37a","country":"PL","accr_number":"AB 682","accr_body":"PCA","test_object":"Środowisko pracy − hałas","test_object_en":"Workplace environment − noise","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A","methodology_en":"A-weighted equivalent sound level Maximum A-weighted sound level","parameters":[{"name":"Zakres","range":"(25 – 135) dB"},{"name":"Szczytowy poziom dźwięku C"},{"name":"Zakres","range":"(35 – 138) dB"},{"name":"Poziom ekspozycji na hałas odniesiony do:"},{"name":"8-godz. dobowego wymiaru czasu pracy"},{"name":"tygodnia pracy (z obliczeń)"}],"parameters_en":[{"name":"Range","range":"(25 – 135) dB"},{"name":"C-weighted peak sound pressure level"},{"name":"Range","range":"(35 – 138) dB"},{"name":"Noise exposure level referred to:"},{"name":"an 8-hour daily working time"},{"name":"the working week (calculated)"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (25 – 135) dB\nSzczytowy poziom dźwięku C\nZakres (35 – 138) dB\nPoziom ekspozycji na hałas odniesiony do:\n8-godz. dobowego wymiaru czasu pracy\ntygodnia pracy (z obliczeń)\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 - punkt 10 Strategię 3 – punkt 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 - punkt 10 Strategię 3 – punkt 11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (25 – 135) dB\nSzczytowy poziom dźwięku C\nZakres (35 – 138) dB\nPoziom ekspozycji na hałas odniesiony do:\n8-godz. dobowego wymiaru czasu pracy\ntygodnia pracy (z obliczeń)\nMetoda pomiarowa bezpośrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 - punkt 10 Strategię 3 – punkt 11 Srodowisko pracy − halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A\nZakres:\nZakres (25 – 135) dB\nSzczytowy poziom dzwieku C\nZakres (35 – 138) dB\nPoziom ekspozycji na halas odniesiony do:\n8-godz. dobowego wymiaru czasu pracy\ntygodnia pracy (z obliczen)\nMetoda pomiarowa bezposrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej Strategie 2 - punkt 10 Strategie 3 – punkt 11","categories":["environment"],"row_index":47,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − noise A-weighted equivalent sound level Maximum A-weighted sound level Direct measurement method Range C-weighted peak sound pressure level Range Noise exposure level referred to: an 8-hour daily working time the working week (calculated) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 - punkt 10 Strategię 3 – punkt 11","methodology_zh":"A 计权等效声级 A 计权最大声级","parameters_zh":[{"name":"范围","range":"(25 – 135) dB"},{"name":"C 计权峰值声级"},{"name":"范围","range":"(35 – 138) dB"},{"name":"噪声暴露级，参照："},{"name":"8 小时日工作时间"},{"name":"工作周（由计算得出）"}],"search_zh":"工作环境 − 噪声 A 计权等效声级 A 计权最大声级 直接测量法 范围 C 计权峰值声级 范围 噪声暴露级，参照： 8 小时日工作时间 工作周（由计算得出） PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 - punkt 10 Strategię 3 – punkt 11","technique_zh":"直接测量法","test_object_zh":"工作环境 − 噪声"},{"_id":"6a5dc9bbf1c10c8ce825dfb9","lab_id":"69ad52a3de79e566650fb37a","country":"PL","accr_number":"AB 682","accr_body":"PCA","test_object":"Środowisko pracy − drgania mechaniczne działające na organizm człowieka przez kończyny górne","test_object_en":"Workplace environment − hand-arm mechanical vibration","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","methodology_en":"Frequency-weighted r.m.s. vibration acceleration","parameters":[{"name":"Zakres","range":"(0,1 – 1000) m/s2"}],"parameters_en":[{"name":"Range","range":"(0,1 – 1000) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia; Metoda próbkowania","techniques":["Metoda pomiarowa bezpośrednia","Metoda próbkowania"],"technique_en":"Direct measurement method; Sampling method","computed":[],"computed_en":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,1 – 1000) m/s2\nMetoda pomiarowa bezpośrednia; Metoda próbkowania","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-2:2004/A1:2015"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − drgania mechaniczne działające na organizm człowieka przez kończyny górne Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,1 – 1000) m/s2\nMetoda pomiarowa bezpośrednia; Metoda próbkowania PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015 Srodowisko pracy − drgania mechaniczne dzialajace na organizm czlowieka przez konczyny gorne Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres (0,1 – 1000) m/s2\nMetoda pomiarowa bezposrednia; Metoda probkowania PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015","categories":["environment"],"row_index":48,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − hand-arm mechanical vibration Frequency-weighted r.m.s. vibration acceleration Direct measurement method; Sampling method Range PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015","methodology_zh":"频率计权振动加速度有效值","parameters_zh":[{"name":"范围","range":"(0,1 – 1000) m/s2"}],"search_zh":"工作环境 － 经上肢作用于人体的机械振动 频率计权振动加速度有效值 直接测量法；采样法 范围 PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015","technique_zh":"直接测量法；采样法","test_object_zh":"工作环境 － 经上肢作用于人体的机械振动"},{"_id":"6a5dc9bbf1c10c8ce825dfba","lab_id":"69ad52a3de79e566650fb37a","country":"PL","accr_number":"AB 682","accr_body":"PCA","test_object":"Środowisko pracy − drgania mechaniczne działające na organizm człowieka przez kończyny górne","test_object_en":"Workplace environment − hand-arm mechanical vibration","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)","methodology_en":"Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-2:2004/A1:2015"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − drgania mechaniczne działające na organizm człowieka przez kończyny górne Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015 Srodowisko pracy − drgania mechaniczne dzialajace na organizm czlowieka przez konczyny gorne Ekspozycja dzienna, wyrazona w postaci rownowaznej energetycznie dla 8-godzin dzialania sumy wektorowej skutecznych, skorygowanych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci sumy wektorowej skutecznych, wazonych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz) (z obliczen) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015","categories":["environment"],"row_index":49,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − hand-arm mechanical vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015","methodology_zh":"日暴露量，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值矢量和的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值的矢量和表示（计算值）","search_zh":"工作环境 － 经上肢作用于人体的机械振动 日暴露量，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值矢量和的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值的矢量和表示（计算值） PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015","test_object_zh":"工作环境 － 经上肢作用于人体的机械振动"},{"_id":"6a5dc9bbf1c10c8ce825dfbb","lab_id":"69ad52a3de79e566650fb37a","country":"PL","accr_number":"AB 682","accr_body":"PCA","test_object":"Środowisko pracy − drgania mechaniczne o ogólnym działaniu na organizm człowieka","test_object_en":"Workplace environment − whole-body mechanical vibration","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","methodology_en":"Frequency-weighted r.m.s. vibration acceleration","parameters":[{"name":"Zakres","range":"(0,01 – 100) m/s2"}],"parameters_en":[{"name":"Range","range":"(0,01 – 100) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia; Metoda próbkowania","techniques":["Metoda pomiarowa bezpośrednia","Metoda próbkowania"],"technique_en":"Direct measurement method; Sampling method","computed":[],"computed_en":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,01 – 100) m/s2\nMetoda pomiarowa bezpośrednia; Metoda próbkowania","reference":"PN-EN-14253 + A1:2011","norm_bases":["PN-EN-14253 + A1:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − drgania mechaniczne o ogólnym działaniu na organizm człowieka Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,01 – 100) m/s2\nMetoda pomiarowa bezpośrednia; Metoda próbkowania PN-EN-14253 + A1:2011 Srodowisko pracy − drgania mechaniczne o ogolnym dzialaniu na organizm czlowieka Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres (0,01 – 100) m/s2\nMetoda pomiarowa bezposrednia; Metoda probkowania PN-EN-14253 + A1:2011","categories":["environment"],"row_index":50,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − whole-body mechanical vibration Frequency-weighted r.m.s. vibration acceleration Direct measurement method; Sampling method Range PN-EN-14253 + A1:2011","methodology_zh":"频率计权振动加速度有效值","parameters_zh":[{"name":"范围","range":"(0,01 – 100) m/s2"}],"search_zh":"工作环境 － 对人体产生全身作用的机械振动 频率计权振动加速度有效值 直接测量法；采样法 范围 PN-EN-14253 + A1:2011","technique_zh":"直接测量法；采样法","test_object_zh":"工作环境 － 对人体产生全身作用的机械振动"},{"_id":"6a5dc9bbf1c10c8ce825dfbc","lab_id":"69ad52a3de79e566650fb37a","country":"PL","accr_number":"AB 682","accr_body":"PCA","test_object":"Środowisko pracy − drgania mechaniczne o ogólnym działaniu na organizm człowieka","test_object_en":"Workplace environment − whole-body mechanical vibration","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń)","methodology_en":"Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz), Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz) (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń)","reference":"PN-EN-14253 + A1:2011","norm_bases":["PN-EN-14253 + A1:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − drgania mechaniczne o ogólnym działaniu na organizm człowieka Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń) PN-EN-14253 + A1:2011 Srodowisko pracy − drgania mechaniczne o ogolnym dzialaniu na organizm czlowieka Ekspozycja dzienna, wyrazona w postaci rownowaznego energetycznie dla 8-godzin dzialania skutecznego, skorygowanego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1.4awx, 1.4awy, awz), Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci skutecznego, wazonego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1.4awx, 1.4awy, awz) (z obliczen) PN-EN-14253 + A1:2011","categories":["environment"],"row_index":51,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − whole-body mechanical vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz), Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz) (calculated) PN-EN-14253 + A1:2011","methodology_zh":"日暴露量，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值表示（计算值）","search_zh":"工作环境 － 对人体产生全身作用的机械振动 日暴露量，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值表示（计算值） PN-EN-14253 + A1:2011","test_object_zh":"工作环境 － 对人体产生全身作用的机械振动"},{"_id":"6a5dc9bbf1c10c8ce825dfbd","lab_id":"69ad52a3de79e566650fb37a","country":"PL","accr_number":"AB 682","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","test_object_en":"Workplace environment − air","methodology":"Pobieranie próbek do oceny narażenia zawodowego na:","methodology_en":"Sampling for the assessment of occupational exposure to:","parameters":[{"name":"pyły przemysłowe"},{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna"},{"name":"substancje nieorganiczne"},{"name":"frakcja respirabilna"}],"parameters_en":[{"name":"industrial dusts"},{"name":"inhalable fraction"},{"name":"respirable fraction"},{"name":"inorganic substances"},{"name":"respirable fraction"}],"technique":"Metoda dozymetrii indywidualnej","techniques":["Metoda dozymetrii indywidualnej"],"technique_en":"Personal dosimetry method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\npyły przemysłowe\nfrakcja wdychalna\nfrakcja respirabilna\nsubstancje nieorganiczne\nfrakcja respirabilna\nMetoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002+Az1:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − powietrze Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\npyły przemysłowe\nfrakcja wdychalna\nfrakcja respirabilna\nsubstancje nieorganiczne\nfrakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy − powietrze Pobieranie probek do oceny narazenia zawodowego na:\nZakres:\npyly przemyslowe\nfrakcja wdychalna\nfrakcja respirabilna\nsubstancje nieorganiczne\nfrakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002+Az1:2004","categories":["environment"],"row_index":52,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − air Sampling for the assessment of occupational exposure to: Personal dosimetry method industrial dusts inhalable fraction respirable fraction inorganic substances respirable fraction PN-Z-04008-7:2002+Az1:2004","methodology_zh":"职业接触评估采样，针对：","parameters_zh":[{"name":"工业粉尘"},{"name":"可吸入组分"},{"name":"呼吸性组分"},{"name":"无机物质"},{"name":"呼吸性组分"}],"search_zh":"工作环境 − 空气 职业接触评估采样，针对： 个体剂量测定法 工业粉尘 可吸入组分 呼吸性组分 无机物质 呼吸性组分 PN-Z-04008-7:2002+Az1:2004","technique_zh":"个体剂量测定法","test_object_zh":"工作环境 − 空气"},{"_id":"6a5dc9bbf1c10c8ce825dfbe","lab_id":"69ad52a3de79e566650fb37a","country":"PL","accr_number":"AB 682","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","test_object_en":"Workplace environment − air","methodology":"Wskaźnik narażenia (z obliczeń)","methodology_en":"Exposure index (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002+Az1:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − powietrze Wskaźnik narażenia (z obliczeń) PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy − powietrze Wskaznik narazenia (z obliczen) PN-Z-04008-7:2002+Az1:2004","categories":["environment"],"row_index":53,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − air Exposure index (calculated) PN-Z-04008-7:2002+Az1:2004","methodology_zh":"暴露指数（计算得出）","search_zh":"工作环境 − 空气 暴露指数（计算得出） PN-Z-04008-7:2002+Az1:2004","test_object_zh":"工作环境 − 空气"},{"_id":"6a5dc9bbf1c10c8ce825dfbf","lab_id":"69ad52a3de79e566650fb37a","country":"PL","accr_number":"AB 682","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","test_object_en":"Workplace environment − air","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia -frakcja wdychalna: -Asfalt naftowy -Apatyty i fosforyty -Cement portlandzki -Ditlenek tytanu -Grafit naturalny -Grafit syntetyczny -Kaolin -Krzemionka bezpostaciowa i syntetyczna -Pyły drewna -Pyły mąki -Pyły niesklasyfikowane ze względu na toksyczność -Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki -Siarczan (VI) wapnia (gips) -Sadza techniczna -Talk -Węgiel (kamienny, brunatny) Węglan magnezu wapnia (dolomit) Węglik krzemu, niewłóknisty","methodology_en":"Concentration of harmful dust agents -inhalable fraction: -Petroleum asphalt -Apatites and phosphorites -Portland cement -Titanium dioxide -Natural graphite -Synthetic graphite -Kaolin -Amorphous and synthetic silica -Wood dust -Flour dust -Dusts not classified according to toxicity -Organic dusts of animal and plant origin except wood and flour dust -Calcium sulphate (VI) (gypsum) -Carbon black -Talc -Coal (hard, brown) Magnesium calcium carbonate (dolomite) Silicon carbide, non-fibrous","parameters":[{"name":"Zakres","range":"(0,12-17,77) mg/m3"}],"parameters_en":[{"name":"Range","range":"(0,12-17,77) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia -frakcja wdychalna: -Asfalt naftowy -Apatyty i fosforyty -Cement portlandzki -Ditlenek tytanu -Grafit naturalny -Grafit syntetyczny -Kaolin -Krzemionka bezpostaciowa i syntetyczna -Pyły drewna -Pyły mąki -Pyły niesklasyfikowane ze względu na toksyczność -Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki -Siarczan (VI) wapnia (gips) -Sadza techniczna -Talk -Węgiel (kamienny, brunatny) Węglan magnezu wapnia (dolomit) Węglik krzemu, niewłóknisty\nZakres (0,12-17,77) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022:08","norm_bases":["PN-Z-04507:2022-05","PN-Z-04507:2022-05/Ap1:2022:08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia -frakcja wdychalna: -Asfalt naftowy -Apatyty i fosforyty -Cement portlandzki -Ditlenek tytanu -Grafit naturalny -Grafit syntetyczny -Kaolin -Krzemionka bezpostaciowa i syntetyczna -Pyły drewna -Pyły mąki -Pyły niesklasyfikowane ze względu na toksyczność -Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki -Siarczan (VI) wapnia (gips) -Sadza techniczna -Talk -Węgiel (kamienny, brunatny) Węglan magnezu wapnia (dolomit) Węglik krzemu, niewłóknisty\nZakres (0,12-17,77) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022:08 Srodowisko pracy − powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia -frakcja wdychalna: -Asfalt naftowy -Apatyty i fosforyty -Cement portlandzki -Ditlenek tytanu -Grafit naturalny -Grafit syntetyczny -Kaolin -Krzemionka bezpostaciowa i syntetyczna -Pyly drewna -Pyly maki -Pyly niesklasyfikowane ze wzgledu na toksycznosc -Pyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki -Siarczan (VI) wapnia (gips) -Sadza techniczna -Talk -Wegiel (kamienny, brunatny) Weglan magnezu wapnia (dolomit) Weglik krzemu, niewloknisty\nZakres (0,12-17,77) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022:08","categories":["environment","construction"],"row_index":54,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − air Concentration of harmful dust agents -inhalable fraction: -Petroleum asphalt -Apatites and phosphorites -Portland cement -Titanium dioxide -Natural graphite -Synthetic graphite -Kaolin -Amorphous and synthetic silica -Wood dust -Flour dust -Dusts not classified according to toxicity -Organic dusts of animal and plant origin except wood and flour dust -Calcium sulphate (VI) (gypsum) -Carbon black -Talc -Coal (hard, brown) Magnesium calcium carbonate (dolomite) Silicon carbide, non-fibrous Gravimetric method Range PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022:08","parameters_zh":[{"name":"范围","range":"(0,12-17,77) mg/m3"}],"search_zh":"工作环境 − 空气 重量法 范围 PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022:08","technique_zh":"重量法","test_object_zh":"工作环境 − 空气"},{"_id":"6a5dc9bbf1c10c8ce825dfc0","lab_id":"69ad52a3de79e566650fb37a","country":"PL","accr_number":"AB 682","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","test_object_en":"Workplace environment − air","methodology":"Stężenie pyłów czynników szkodliwych dla zdrowia","methodology_en":"Concentration of harmful dust agents","parameters":[{"name":"frakcja respirabilna: -Apatyty i fosforyty -Cement portlandzki -Grafit naturalny -Krzemionka bezpostaciowa i syntetyczna -Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki -Spaliny silnika Diesla"},{"name":"Talk -Węgiel (kamienny i brunatny)"},{"name":"Zakres","range":"(0,05-15,53) mg/m3"}],"parameters_en":[{"name":"respirable fraction: -Apatites and phosphorites -Portland cement -Natural graphite -Amorphous and synthetic silica -Organic dusts of animal and plant origin excluding wood and flour dusts -Diesel engine exhaust"},{"name":"Talc - Coal (hard and brown)"},{"name":"Range","range":"(0,05-15,53) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie pyłów czynników szkodliwych dla zdrowia\nZakres:\nfrakcja respirabilna: -Apatyty i fosforyty -Cement portlandzki -Grafit naturalny -Krzemionka bezpostaciowa i syntetyczna -Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki -Spaliny silnika Diesla\nTalk -Węgiel (kamienny i brunatny)\nZakres (0,05-15,53) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022:08","norm_bases":["PN-Z-04508:2022-05","PN-Z-04508:2022-05/Ap1:2022:08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − powietrze Stężenie pyłów czynników szkodliwych dla zdrowia\nZakres:\nfrakcja respirabilna: -Apatyty i fosforyty -Cement portlandzki -Grafit naturalny -Krzemionka bezpostaciowa i syntetyczna -Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki -Spaliny silnika Diesla\nTalk -Węgiel (kamienny i brunatny)\nZakres (0,05-15,53) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022:08 Srodowisko pracy − powietrze Stezenie pylow czynnikow szkodliwych dla zdrowia\nZakres:\nfrakcja respirabilna: -Apatyty i fosforyty -Cement portlandzki -Grafit naturalny -Krzemionka bezpostaciowa i syntetyczna -Pyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki -Spaliny silnika Diesla\nTalk -Wegiel (kamienny i brunatny)\nZakres (0,05-15,53) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022:08","categories":["environment","construction"],"row_index":55,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − air Concentration of harmful dust agents Gravimetric method respirable fraction: -Apatites and phosphorites -Portland cement -Natural graphite -Amorphous and synthetic silica -Organic dusts of animal and plant origin excluding wood and flour dusts -Diesel engine exhaust Talc - Coal (hard and brown) Range PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022:08","parameters_zh":[{"name":"frakcja respirabilna: -Apatyty i fosforyty -Cement portlandzki -Grafit naturalny -Krzemionka bezpostaciowa i syntetyczna -Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki -Spaliny silnika Diesla"},{"name":"Talk -Węgiel (kamienny i brunatny)"},{"name":"范围","range":"(0,05-15,53) mg/m3"}],"search_zh":"工作环境 − 空气 重量法 范围 PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022:08","technique_zh":"重量法","test_object_zh":"工作环境 − 空气"},{"_id":"6a5dc9bbf1c10c8ce825dfc1","lab_id":"69ad52a3de79e566650fb37a","country":"PL","accr_number":"AB 682","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda na pływalniach","test_object_en":"Water intended for human consumption, Swimming pool water","methodology":"Pobieranie próbek do badań mikrobiologicznych","methodology_en":"Sampling for microbiological testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.2; 4.4.4; 4.4.5; 4.4.6","norm_bases":["PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.2; 4.4.4; 4.4.5; 4.4.6"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi, Woda na pływalniach Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.2; 4.4.4; 4.4.5; 4.4.6 Woda do spozycia przez ludzi, Woda na plywalniach Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007 z wylaczeniem pkt. 4.4.2; 4.4.4; 4.4.5; 4.4.6","categories":["water","microbiology"],"row_index":56,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption, Swimming pool water Sampling for microbiological testing PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.2; 4.4.4; 4.4.5; 4.4.6","methodology_zh":"微生物检测用样品采集","search_zh":"生活饮用水、游泳池水 微生物检测用样品采集 PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.2; 4.4.4; 4.4.5; 4.4.6","test_object_zh":"生活饮用水、游泳池水"}],"has_pdf":true}