{"lab":{"_id":"69ad52a3de79e566650fb376","accr_number":"AB 680","country":"PL","accr_body":"PCA","address":"ul. Mickiewicza 28/30, 86-300 Grudziądz, LABORATORIUM CENTRALNE, ul. Curie-Skłodowskiej 10","categories":["water","environment","microbiology","materials"],"city":"Grudziądz","imported_at":"2026-03-08T10:42:43.265Z","methods_count":139,"name":"MIEJSKIE WODOCIĄGI I OCZYSZCZALNIA Sp. z o.o.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_680.pdf"],"scope_summary":"","search_text":"miejskie wodociągi i oczyszczalnia sp. z o.o. ul. mickiewicza 28/30, 86-300 grudziądz, laboratorium centralne, ul. curie-skłodowskiej 10 water other pharma electronics microbiology environment materials food automotive","status":"active","updated_at":"2026-03-08T14:51:34.894Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:34.894Z","email_confidence":"high","email_mx":true,"email_source":"https://www.pca.gov.pl/akredytowane-podmioty/akredytacje-aktywne/laboratoria-badawcze/AB%20680,podmiot.html","fields_of_testing":[{"codes":"B/32/P","pl":"Badania biologiczne i biochemiczne oraz pobieranie próbek osadów","en":"Biological and biochemical tests and sampling of sediments"},{"codes":"C/28/P; C/29/P; C/30/P; C/31/P; C/32/P","pl":"Badania chemiczne i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków, gleb, odpadów, osadów","en":"Chemical tests and sampling of water, drinking water, sewage, soil, waste, sediments"},{"codes":"C/36","pl":"Badania chemiczne gazów składowiskowych","en":"Chemical tests of landfill gases"},{"codes":"C/44/P","pl":"Badania chemiczne i pobieranie próbek środków wspomagających uprawę roślin","en":"Chemical tests and sampling of plant growth substances"},{"codes":"K/28/P, K/29/P, K/32/P; K/44/P","pl":"Badania mikrobiologiczne i pobieranie próbek wody, wody do spożycia przez ludzi, osadów, środków wspomagających uprawę roślin","en":"Microbiological tests and sampling of water, drinking water, sediments, plant growth substances"},{"codes":"N/28/P; N/29/P; N/30/P; N/31/P; N/32/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków, gleb, odpadów, osadów","en":"Tests of physical properties and sampling of water, drinking water, sewage, soil, waste, sediments"},{"codes":"N/36","pl":"Badania właściwości fizycznych gazów składowiskowych","en":"Tests of physical properties of landfill gases"},{"codes":"N/44/P","pl":"Badania właściwości fizycznych i pobieranie próbek środków wspomagających uprawę roślin","en":"Tests of physical properties and sampling of plant growth substances"},{"codes":"Q/28/P, Q/29/P","pl":"Badania sensoryczne i pobieranie próbek wody, wody do spożycia przez ludzi","en":"Sensory tests and sampling of water, drinking water"}],"issue":{"no":"23","date":"19.12.2025"},"parse_date":"2026-07-20T07:09:47.334Z","parse_source":"script-pdfplumber","map_coord":[53.490688,18.753091],"map_geo":"nominatim-street","has_en":true,"category_counts":{"water":104,"environment":30,"microbiology":8,"other":7,"materials":6,"metrology":1,"petro":1,"construction":1},"category_scores":{"water":68.46,"environment":5.7,"microbiology":0.41,"other":0.31,"materials":0.23,"metrology":0.01,"petro":0.01,"construction":0.01},"has_zh":true},"methods":[{"_id":"6a5dc9bbf1c10c8ce825dee1","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PL-IO-22 wydanie 01 z dnia 15.01.2017 r.","norm_bases":["PL-IO-22 wydanie 01 z dnia 15.01.2017 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Pobieranie próbek do badań chemicznych i fizycznych PL-IO-22 wydanie 01 z dnia 15.01.2017 r. Woda na plywalniach Pobieranie probek do badan chemicznych i fizycznych PL-IO-22 wydanie 01 z dnia 15.01.2017 r.","categories":["water"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water Sampling for chemical and physical testing PL-IO-22 wydanie 01 z dnia 15.01.2017 r.","methodology_zh":"化学与物理检测用样品采集","search_zh":"游泳池水 化学与物理检测用样品采集 PL-IO-22 wydanie 01 z dnia 15.01.2017 r.","test_object_zh":"游泳池水"},{"_id":"6a5dc9bbf1c10c8ce825dee2","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Woda powierzchniowa","test_object_en":"Surface water","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-EN ISO 5667-6:2016-12 z wyłączeniem p. 7.5, 7.6","norm_bases":["PN-EN ISO 5667-6:2016-12 z wyłączeniem p. 7.5, 7.6"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda powierzchniowa Pobieranie próbek do badań chemicznych i fizycznych PN-EN ISO 5667-6:2016-12 z wyłączeniem p. 7.5, 7.6 Woda powierzchniowa Pobieranie probek do badan chemicznych i fizycznych PN-EN ISO 5667-6:2016-12 z wylaczeniem p. 7.5, 7.6","categories":["water"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Surface water Sampling for chemical and physical testing PN-EN ISO 5667-6:2016-12 z wyłączeniem p. 7.5, 7.6","methodology_zh":"化学与物理检测用样品采集","search_zh":"地表水 化学与物理检测用样品采集 PN-EN ISO 5667-6:2016-12 z wyłączeniem p. 7.5, 7.6","test_object_zh":"地表水"},{"_id":"6a5dc9bbf1c10c8ce825dee3","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody","methodology_en":"Sampling for chemical and physical testing Temperature of the water sample taken","parameters":[{"name":"Zakres","range":"(1,0 – 60,0)°C"}],"parameters_en":[{"name":"Range","range":"(1,0 – 60,0)°C"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody\nZakres (1,0 – 60,0)°C","reference":"PN-ISO 5667-5:2017-10 | PN-77/C-04584","norm_bases":["PN-ISO 5667-5:2017-10","PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody\nZakres (1,0 – 60,0)°C PN-ISO 5667-5:2017-10 | PN-77/C-04584 Woda, woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych Temperatura pobranej probki wody\nZakres (1,0 – 60,0)°C PN-ISO 5667-5:2017-10 | PN-77/C-04584","categories":["water"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Sampling for chemical and physical testing Temperature of the water sample taken Range PN-ISO 5667-5:2017-10 | PN-77/C-04584","parameters_zh":[{"name":"范围","range":"(1,0 – 60,0)°C"}],"search_zh":"水、生活饮用水 化学和物理检测采样 所采水样的温度 范围 PN-ISO 5667-5:2017-10 | PN-77/C-04584","test_object_zh":"水、生活饮用水","methodology_zh":"化学和物理检测采样 所采水样的温度"},{"_id":"6a5dc9bbf1c10c8ce825dee4","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Woda podziemna","test_object_en":"Groundwater","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody","methodology_en":"Sampling for chemical and physical testing Temperature of the water sample taken","parameters":[{"name":"Zakres","range":"(1,0 – 60,0)°C"}],"parameters_en":[{"name":"Range","range":"(1,0 – 60,0)°C"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody\nZakres (1,0 – 60,0)°C","reference":"PN-ISO 5667-11:2017-10 z wyłączeniem p. 5.2, 6.2, 6.3 | PN-77/C-04584","norm_bases":["PN-ISO 5667-11:2017-10 z wyłączeniem p. 5.2, 6.2, 6.3","PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda podziemna Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody\nZakres (1,0 – 60,0)°C PN-ISO 5667-11:2017-10 z wyłączeniem p. 5.2, 6.2, 6.3 | PN-77/C-04584 Woda podziemna Pobieranie probek do badan chemicznych i fizycznych Temperatura pobranej probki wody\nZakres (1,0 – 60,0)°C PN-ISO 5667-11:2017-10 z wylaczeniem p. 5.2, 6.2, 6.3 | PN-77/C-04584","categories":["water"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Groundwater Sampling for chemical and physical testing Temperature of the water sample taken Range PN-ISO 5667-11:2017-10 z wyłączeniem p. 5.2, 6.2, 6.3 | PN-77/C-04584","parameters_zh":[{"name":"范围","range":"(1,0 – 60,0)°C"}],"search_zh":"地下水 化学和物理检测采样 所采水样的温度 范围 PN-ISO 5667-11:2017-10 z wyłączeniem p. 5.2, 6.2, 6.3 | PN-77/C-04584","methodology_zh":"化学和物理检测采样 所采水样的温度","test_object_zh":"地下水"},{"_id":"6a5dc9bbf1c10c8ce825dee5","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach)","test_object_en":"Water (including swimming pool water)","methodology":"Stężenie chloru wolnego, + całkowitego","methodology_en":"Free, + total chlorine concentration","parameters":[{"name":"Zakres","range":"(0,02 – 2,00) mg/l"},{"name":"Stężenie chloru związanego (z obliczeń)"}],"parameters_en":[{"name":"Range","range":"(0,02 – 2,00) mg/l"},{"name":"Combined chlorine concentration (calculated)"}],"technique":"Metoda kolorymetryczna","techniques":["Metoda kolorymetryczna"],"technique_en":"Colorimetric method","computed":[],"computed_en":[],"activity":"Stężenie chloru wolnego, + całkowitego\nZakres:\nZakres (0,02 – 2,00) mg/l\nStężenie chloru związanego (z obliczeń)\nMetoda kolorymetryczna","reference":"PL-PB-30 wydanie 06 z dnia 28.10.2025 r. | na podstawie metody HACH nr 8021 i 8167","norm_bases":["PL-PB-30 wydanie 06 z dnia 28.10.2025 r.","na podstawie metody HACH nr 8021 i 8167"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach) Stężenie chloru wolnego, + całkowitego\nZakres:\nZakres (0,02 – 2,00) mg/l\nStężenie chloru związanego (z obliczeń)\nMetoda kolorymetryczna PL-PB-30 wydanie 06 z dnia 28.10.2025 r. | na podstawie metody HACH nr 8021 i 8167 Woda (w tym woda na plywalniach) Stezenie chloru wolnego, + calkowitego\nZakres:\nZakres (0,02 – 2,00) mg/l\nStezenie chloru zwiazanego (z obliczen)\nMetoda kolorymetryczna PL-PB-30 wydanie 06 z dnia 28.10.2025 r. | na podstawie metody HACH nr 8021 i 8167","categories":["water"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water (including swimming pool water) Free, + total chlorine concentration Colorimetric method Range Combined chlorine concentration (calculated) PL-PB-30 wydanie 06 z dnia 28.10.2025 r. | na podstawie metody HACH nr 8021 i 8167","parameters_zh":[{"name":"范围","range":"(0,02 – 2,00) mg/l"},{"name":"化合氯浓度（计算值）"}],"search_zh":"水（含游泳池水） 比色法 范围 化合氯浓度（计算值） PL-PB-30 wydanie 06 z dnia 28.10.2025 r. | na podstawie metody HACH nr 8021 i 8167","technique_zh":"比色法","test_object_zh":"水（含游泳池水）"},{"_id":"6a5dc9bbf1c10c8ce825dee6","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach)","test_object_en":"Water (including swimming pool water)","methodology":"Mętność","methodology_en":"Turbidity","parameters":[{"name":"Zakres","range":"(0,10 − 40) NTU"}],"parameters_en":[{"name":"Range","range":"(0,10 − 40) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"technique_en":"Nephelometric method","computed":[],"computed_en":[],"activity":"Mętność\nZakres (0,10 − 40) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach) Mętność\nZakres (0,10 − 40) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda (w tym woda na plywalniach) Metnosc\nZakres (0,10 − 40) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water (including swimming pool water) Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,10 − 40) NTU"}],"search_zh":"水（含游泳池水） 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"水（含游泳池水）"},{"_id":"6a5dc9bbf1c10c8ce825dee7","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach)","test_object_en":"Water (including swimming pool water)","methodology":"Indeks nadmanganianowy","methodology_en":"Permanganate index","parameters":[{"name":"Zakres","range":"(0,5 − 7,0) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(0,5 − 7,0) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Indeks nadmanganianowy\nZakres (0,5 − 7,0) mg/l O2\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach) Indeks nadmanganianowy\nZakres (0,5 − 7,0) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda (w tym woda na plywalniach) Indeks nadmanganianowy\nZakres (0,5 − 7,0) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water (including swimming pool water) Permanganate index Titrimetric method Range PN-EN ISO 8467:2001","methodology_zh":"高锰酸盐指数","parameters_zh":[{"name":"范围","range":"(0,5 − 7,0) mg/l O2"}],"search_zh":"水（含游泳池水） 高锰酸盐指数 滴定法 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"水（含游泳池水）"},{"_id":"6a5dc9bbf1c10c8ce825dee8","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach)","test_object_en":"Water (including swimming pool water)","methodology":"Stężenie azotu azotanowego","methodology_en":"Nitrate nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,04 – 11,3) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,04 – 11,3) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu azotanowego\nZakres (0,04 – 11,3) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach) Stężenie azotu azotanowego\nZakres (0,04 – 11,3) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08 Woda (w tym woda na plywalniach) Stezenie azotu azotanowego\nZakres (0,04 – 11,3) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water (including swimming pool water) Nitrate nitrogen concentration Spectrophotometric method Range PN-82/C-04576/08","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,04 – 11,3) mg/l"}],"search_zh":"水（含游泳池水） 硝态氮浓度 分光光度法 范围 PN-82/C-04576/08","technique_zh":"分光光度法","test_object_zh":"水（含游泳池水）"},{"_id":"6a5dc9bbf1c10c8ce825dee9","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Liczba progowa zapachu","methodology_en":"Odour threshold number","parameters":[{"name":"Zakres","range":"(1 – 2) TON"}],"parameters_en":[{"name":"Range","range":"(1 – 2) TON"}],"technique":"Metoda parzysta, uproszczona, wybór niewymuszony","techniques":["Metoda parzysta, uproszczona, wybór niewymuszony"],"technique_en":"Paired method, simplified, non-forced choice","computed":[],"computed_en":[],"activity":"Liczba progowa zapachu\nZakres (1 – 2) TON\nMetoda parzysta, uproszczona, wybór niewymuszony","reference":"PN-EN 1622:2006","norm_bases":["PN-EN 1622:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Liczba progowa zapachu\nZakres (1 – 2) TON\nMetoda parzysta, uproszczona, wybór niewymuszony PN-EN 1622:2006 Woda, woda do spozycia przez ludzi Liczba progowa zapachu\nZakres (1 – 2) TON\nMetoda parzysta, uproszczona, wybor niewymuszony PN-EN 1622:2006","categories":["water"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Odour threshold number Paired method, simplified, non-forced choice Range PN-EN 1622:2006","parameters_zh":[{"name":"范围","range":"(1 – 2) TON"}],"search_zh":"水、生活饮用水 范围 PN-EN 1622:2006","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9bbf1c10c8ce825deea","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Liczba progowa smaku","methodology_en":"Taste threshold number","parameters":[{"name":"Zakres","range":"(1 – 2) TFN"}],"parameters_en":[{"name":"Range","range":"(1 – 2) TFN"}],"technique":"Metoda parzysta, uproszczona, wybór niewymuszony","techniques":["Metoda parzysta, uproszczona, wybór niewymuszony"],"technique_en":"Paired method, simplified, non-forced choice","computed":[],"computed_en":[],"activity":"Liczba progowa smaku\nZakres (1 – 2) TFN\nMetoda parzysta, uproszczona, wybór niewymuszony","reference":"PN-EN 1622:2006","norm_bases":["PN-EN 1622:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Liczba progowa smaku\nZakres (1 – 2) TFN\nMetoda parzysta, uproszczona, wybór niewymuszony PN-EN 1622:2006 Woda do spozycia przez ludzi Liczba progowa smaku\nZakres (1 – 2) TFN\nMetoda parzysta, uproszczona, wybor niewymuszony PN-EN 1622:2006","categories":["water"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Taste threshold number Paired method, simplified, non-forced choice Range PN-EN 1622:2006","parameters_zh":[{"name":"范围","range":"(1 – 2) TFN"}],"search_zh":"生活饮用水 范围 PN-EN 1622:2006","test_object_zh":"生活饮用水"},{"_id":"6a5dc9bbf1c10c8ce825deeb","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"3,0 – 10,0"}],"parameters_en":[{"name":"Range","range":"3,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 3,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda pH\nZakres 3,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda pH\nZakres 3,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"3,0 – 10,0"}],"search_zh":"水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水"},{"_id":"6a5dc9bbf1c10c8ce825deec","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Przewodność elektryczna właściwa","methodology_en":"Electrical conductivity","parameters":[{"name":"Zakres","range":"(5 − 5000) μS/cm"}],"parameters_en":[{"name":"Range","range":"(5 − 5000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"technique_en":"Conductometric method","computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa\nZakres (5 − 5000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Przewodność elektryczna właściwa\nZakres (5 − 5000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda Przewodnosc elektryczna wlasciwa\nZakres (5 − 5000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Electrical conductivity Conductometric method Range PN-EN 27888:1999","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(5 − 5000) μS/cm"}],"search_zh":"水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水"},{"_id":"6a5dc9bbf1c10c8ce825deed","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)","methodology_en":"Total content of calcium and magnesium (total hardness)","parameters":[{"name":"Zakres","range":"(5 − 500) mg/l CaCO3"},{"name":"Zakres","range":"(0,05 – 5) mmol/l"}],"parameters_en":[{"name":"Range","range":"(5 − 500) mg/l CaCO3"},{"name":"Range","range":"(0,05 – 5) mmol/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres:\nZakres (5 − 500) mg/l CaCO3\nZakres (0,05 – 5) mmol/l\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres:\nZakres (5 − 500) mg/l CaCO3\nZakres (0,05 – 5) mmol/l\nMetoda miareczkowa PN-ISO 6059:1999 Woda Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna)\nZakres:\nZakres (5 − 500) mg/l CaCO3\nZakres (0,05 – 5) mmol/l\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Total content of calcium and magnesium (total hardness) Titrimetric method Range Range PN-ISO 6059:1999","methodology_zh":"钙与镁总量（总硬度）","parameters_zh":[{"name":"范围","range":"(5 − 500) mg/l CaCO3"},{"name":"范围","range":"(0,05 – 5) mmol/l"}],"search_zh":"水 钙与镁总量（总硬度） 滴定法 范围 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"水"},{"_id":"6a5dc9bbf1c10c8ce825deee","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Zasadowość ogólna","methodology_en":"Total alkalinity","parameters":[{"name":"Zakres","range":"(4,0 – 10,0) mmol/l"}],"parameters_en":[{"name":"Range","range":"(4,0 – 10,0) mmol/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Zasadowość ogólna\nZakres (4,0 – 10,0) mmol/l\nMetoda miareczkowa","reference":"PN-EN ISO 9963-1:2001 p. 8.2.2 + Ap1:2004","norm_bases":["PN-EN ISO 9963-1:2001 p. 8.2.2 + Ap1:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Zasadowość ogólna\nZakres (4,0 – 10,0) mmol/l\nMetoda miareczkowa PN-EN ISO 9963-1:2001 p. 8.2.2 + Ap1:2004 Woda Zasadowosc ogolna\nZakres (4,0 – 10,0) mmol/l\nMetoda miareczkowa PN-EN ISO 9963-1:2001 p. 8.2.2 + Ap1:2004","categories":["water"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Total alkalinity Titrimetric method Range PN-EN ISO 9963-1:2001 p. 8.2.2 + Ap1:2004","parameters_zh":[{"name":"范围","range":"(4,0 – 10,0) mmol/l"}],"search_zh":"水 总碱度 滴定法 范围 PN-EN ISO 9963-1:2001 p. 8.2.2 + Ap1:2004","technique_zh":"滴定法","test_object_zh":"水","methodology_zh":"总碱度"},{"_id":"6a5dc9bbf1c10c8ce825deef","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Wodorowęglany (HCO3-) (z obliczeń)","methodology_en":"Bicarbonates (HCO3-) (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wodorowęglany (HCO3-) (z obliczeń)","reference":"PN-EN ISO 9963-1:2001 p. 8.2.2 + Ap1:2004","norm_bases":["PN-EN ISO 9963-1:2001 p. 8.2.2 + Ap1:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Wodorowęglany (HCO3-) (z obliczeń) PN-EN ISO 9963-1:2001 p. 8.2.2 + Ap1:2004 Woda Wodoroweglany (HCO3-) (z obliczen) PN-EN ISO 9963-1:2001 p. 8.2.2 + Ap1:2004","categories":["water"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Bicarbonates (HCO3-) (calculated) PN-EN ISO 9963-1:2001 p. 8.2.2 + Ap1:2004","search_zh":"水 PN-EN ISO 9963-1:2001 p. 8.2.2 + Ap1:2004","test_object_zh":"水"},{"_id":"6a5dc9bbf1c10c8ce825def0","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Barwa","methodology_en":"Colour","parameters":[{"name":"Zakres","range":"(5 − 50) mg/l Pt"}],"parameters_en":[{"name":"Range","range":"(5 − 50) mg/l Pt"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"technique_en":"Visual method","computed":[],"computed_en":[],"activity":"Barwa\nZakres (5 − 50) mg/l Pt\nMetoda wizualna","reference":"PN-EN ISO 7887:2012 p. 7 + Ap1:2015-06","norm_bases":["PN-EN ISO 7887:2012 p. 7 + Ap1:2015-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Barwa\nZakres (5 − 50) mg/l Pt\nMetoda wizualna PN-EN ISO 7887:2012 p. 7 + Ap1:2015-06 Woda Barwa\nZakres (5 − 50) mg/l Pt\nMetoda wizualna PN-EN ISO 7887:2012 p. 7 + Ap1:2015-06","categories":["water"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Colour Visual method Range PN-EN ISO 7887:2012 p. 7 + Ap1:2015-06","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(5 − 50) mg/l Pt"}],"search_zh":"水 色度 目视法 范围 PN-EN ISO 7887:2012 p. 7 + Ap1:2015-06","technique_zh":"目视法","test_object_zh":"水"},{"_id":"6a5dc9bbf1c10c8ce825def1","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Barwa","methodology_en":"Colour","parameters":[{"name":"Zakres","range":"(5 − 250) mg/l Pt"}],"parameters_en":[{"name":"Range","range":"(5 − 250) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Barwa\nZakres (5 − 250) mg/l Pt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012 p. 6 + Ap1:2015-06","norm_bases":["PN-EN ISO 7887:2012 p. 6 + Ap1:2015-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Barwa\nZakres (5 − 250) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 p. 6 + Ap1:2015-06 Woda Barwa\nZakres (5 − 250) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 p. 6 + Ap1:2015-06","categories":["water"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Colour Spectrophotometric method Range PN-EN ISO 7887:2012 p. 6 + Ap1:2015-06","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(5 − 250) mg/l Pt"}],"search_zh":"水 色度 分光光度法 范围 PN-EN ISO 7887:2012 p. 6 + Ap1:2015-06","technique_zh":"分光光度法","test_object_zh":"水"},{"_id":"6a5dc9bbf1c10c8ce825def2","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Substancje rozpuszczone, sucha pozostałość","methodology_en":"Dissolved solids, dry residue","parameters":[{"name":"Zakres","range":"(300 − 1600) mg/l"}],"parameters_en":[{"name":"Range","range":"(300 − 1600) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Substancje rozpuszczone, sucha pozostałość\nZakres (300 − 1600) mg/l\nMetoda wagowa","reference":"PN-78/C-04541","norm_bases":["PN-78/C-04541"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Substancje rozpuszczone, sucha pozostałość\nZakres (300 − 1600) mg/l\nMetoda wagowa PN-78/C-04541 Woda Substancje rozpuszczone, sucha pozostalosc\nZakres (300 − 1600) mg/l\nMetoda wagowa PN-78/C-04541","categories":["water"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Dissolved solids, dry residue Gravimetric method Range PN-78/C-04541","parameters_zh":[{"name":"范围","range":"(300 − 1600) mg/l"}],"search_zh":"水 重量法 范围 PN-78/C-04541","technique_zh":"重量法","test_object_zh":"水"},{"_id":"6a5dc9bbf1c10c8ce825def3","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie manganu","methodology_en":"Manganese concentration","parameters":[{"name":"Zakres","range":"(50 – 1000) μg/l"}],"parameters_en":[{"name":"Range","range":"(50 – 1000) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie manganu\nZakres (50 – 1000) μg/l\nMetoda spektrofotometryczna","reference":"PN-92/C-04590/02","norm_bases":["PN-92/C-04590/02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie manganu\nZakres (50 – 1000) μg/l\nMetoda spektrofotometryczna PN-92/C-04590/02 Woda Stezenie manganu\nZakres (50 – 1000) μg/l\nMetoda spektrofotometryczna PN-92/C-04590/02","categories":["water"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Manganese concentration Spectrophotometric method Range PN-92/C-04590/02","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(50 – 1000) μg/l"}],"search_zh":"水 锰浓度 分光光度法 范围 PN-92/C-04590/02","technique_zh":"分光光度法","test_object_zh":"水"},{"_id":"6a5dc9bbf1c10c8ce825def4","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie wapnia","methodology_en":"Calcium concentration","parameters":[{"name":"Zakres","range":"(2 − 140) mg/l"},{"name":"Twardość wapniowa"},{"name":"Zakres","range":"(0,05 – 3,5) mmol/l"}],"parameters_en":[{"name":"Range","range":"(2 − 140) mg/l"},{"name":"Calcium hardness"},{"name":"Range","range":"(0,05 – 3,5) mmol/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie wapnia\nZakres:\nZakres (2 − 140) mg/l\nTwardość wapniowa\nZakres (0,05 – 3,5) mmol/l\nMetoda miareczkowa","reference":"PN-ISO 6058:1999","norm_bases":["PN-ISO 6058:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie wapnia\nZakres:\nZakres (2 − 140) mg/l\nTwardość wapniowa\nZakres (0,05 – 3,5) mmol/l\nMetoda miareczkowa PN-ISO 6058:1999 Woda Stezenie wapnia\nZakres:\nZakres (2 − 140) mg/l\nTwardosc wapniowa\nZakres (0,05 – 3,5) mmol/l\nMetoda miareczkowa PN-ISO 6058:1999","categories":["water"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Calcium concentration Titrimetric method Range Calcium hardness Range PN-ISO 6058:1999","parameters_zh":[{"name":"范围","range":"(2 − 140) mg/l"},{"name":"钙硬度"},{"name":"范围","range":"(0,05 – 3,5) mmol/l"}],"search_zh":"水 钙浓度 滴定法 范围 钙硬度 范围 PN-ISO 6058:1999","technique_zh":"滴定法","test_object_zh":"水","methodology_zh":"钙浓度"},{"_id":"6a5dc9bbf1c10c8ce825def5","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie magnezu (z obliczeń)","methodology_en":"Magnesium concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie magnezu (z obliczeń)","reference":"PN-C-04554-4:1999 Zał. A","norm_bases":["PN-C-04554-4:1999 Zał. A"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie magnezu (z obliczeń) PN-C-04554-4:1999 Zał. A Woda Stezenie magnezu (z obliczen) PN-C-04554-4:1999 Zal. A","categories":["water"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Magnesium concentration (calculated) PN-C-04554-4:1999 Zał. A","search_zh":"水 镁浓度（计算值） PN-C-04554-4:1999 Zał. A","test_object_zh":"水","methodology_zh":"镁浓度（计算值）"},{"_id":"6a5dc9bbf1c10c8ce825def6","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie ortofosforanów","methodology_en":"Orthophosphate concentration","parameters":[{"name":"Zakres","range":"(0,025 − 0,80) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,025 − 0,80) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie ortofosforanów\nZakres (0,025 − 0,80) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 p. 4 + Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 p. 4 + Ap1:2010+Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie ortofosforanów\nZakres (0,025 − 0,80) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 p. 4 + Ap1:2010+Ap2:2010 Woda Stezenie ortofosforanow\nZakres (0,025 − 0,80) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 p. 4 + Ap1:2010+Ap2:2010","categories":["water"],"row_index":21,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Orthophosphate concentration Spectrophotometric method Range PN-EN ISO 6878:2006 p. 4 + Ap1:2010+Ap2:2010","parameters_zh":[{"name":"范围","range":"(0,025 − 0,80) mg/l"}],"search_zh":"水 正磷酸盐浓度 分光光度法 范围 PN-EN ISO 6878:2006 p. 4 + Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水","methodology_zh":"正磷酸盐浓度"},{"_id":"6a5dc9bbf1c10c8ce825def7","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie krzemionki","methodology_en":"Silica concentration","parameters":[{"name":"Zakres","range":"(5,0 − 50) mg/l"}],"parameters_en":[{"name":"Range","range":"(5,0 − 50) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie krzemionki\nZakres (5,0 − 50) mg/l\nMetoda spektrofotometryczna","reference":"PN-71/C-04567/02","norm_bases":["PN-71/C-04567/02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie krzemionki\nZakres (5,0 − 50) mg/l\nMetoda spektrofotometryczna PN-71/C-04567/02 Woda Stezenie krzemionki\nZakres (5,0 − 50) mg/l\nMetoda spektrofotometryczna PN-71/C-04567/02","categories":["water"],"row_index":22,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Silica concentration Spectrophotometric method Range PN-71/C-04567/02","parameters_zh":[{"name":"范围","range":"(5,0 − 50) mg/l"}],"search_zh":"水 二氧化硅浓度 分光光度法 范围 PN-71/C-04567/02","technique_zh":"分光光度法","test_object_zh":"水","methodology_zh":"二氧化硅浓度"},{"_id":"6a5dc9bbf1c10c8ce825def8","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie chromu (VI)","methodology_en":"Chromium(VI) concentration","parameters":[{"name":"Zakres","range":"(2 – 50) μg/l"}],"parameters_en":[{"name":"Range","range":"(2 – 50) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie chromu (VI)\nZakres (2 – 50) μg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 18412:2007","norm_bases":["PN-EN ISO 18412:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie chromu (VI)\nZakres (2 – 50) μg/l\nMetoda spektrofotometryczna PN-EN ISO 18412:2007 Woda Stezenie chromu (VI)\nZakres (2 – 50) μg/l\nMetoda spektrofotometryczna PN-EN ISO 18412:2007","categories":["water"],"row_index":23,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Chromium(VI) concentration Spectrophotometric method Range PN-EN ISO 18412:2007","parameters_zh":[{"name":"范围","range":"(2 – 50) μg/l"}],"search_zh":"水 六价铬浓度 分光光度法 范围 PN-EN ISO 18412:2007","technique_zh":"分光光度法","test_object_zh":"水","methodology_zh":"六价铬浓度"},{"_id":"6a5dc9bbf1c10c8ce825def9","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie azotu Kjeldahla","methodology_en":"Kjeldahl nitrogen concentration","parameters":[{"name":"Zakres","range":"(1,0 − 5,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(1,0 − 5,0) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie azotu Kjeldahla\nZakres (1,0 − 5,0) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie azotu Kjeldahla\nZakres (1,0 − 5,0) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Woda Stezenie azotu Kjeldahla\nZakres (1,0 − 5,0) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":24,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Kjeldahl nitrogen concentration Titrimetric method Range PN-EN 25663:2001","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(1,0 − 5,0) mg/l"}],"search_zh":"水 凯氏氮浓度 滴定法 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"水"},{"_id":"6a5dc9bbf1c10c8ce825defa","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Biochemiczne zapotrzebowanie tlenu (BZT5)","methodology_en":"Biochemical oxygen demand (BOD5)","parameters":[{"name":"Zakres","range":"(3,0 – 6000) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(3,0 – 6000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu (BZT5)\nZakres (3,0 – 6000) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Biochemiczne zapotrzebowanie tlenu (BZT5)\nZakres (3,0 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Woda Biochemiczne zapotrzebowanie tlenu (BZT5)\nZakres (3,0 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":25,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Biochemical oxygen demand (BOD5) Electrochemical method Range PN-EN ISO 5815-1:2019-12","parameters_zh":[{"name":"范围","range":"(3,0 – 6000) mg/l O2"}],"search_zh":"水 五日生化需氧量（BOD5） 电化学法 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a5dc9bbf1c10c8ce825defb","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Zawiesiny ogólne","methodology_en":"Total suspended solids (TSS)","parameters":[{"name":"Zakres","range":"(2,0 − 50) mg/l"}],"parameters_en":[{"name":"Range","range":"(2,0 − 50) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawiesiny ogólne\nZakres (2,0 − 50) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Zawiesiny ogólne\nZakres (2,0 − 50) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda Zawiesiny ogolne\nZakres (2,0 − 50) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":26,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 − 50) mg/l"}],"search_zh":"水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"水"},{"_id":"6a5dc9bbf1c10c8ce825defc","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie azotu amonowego","methodology_en":"Ammonium nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,05 – 10,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,05 – 10,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego\nZakres (0,05 – 10,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie azotu amonowego\nZakres (0,05 – 10,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda Stezenie azotu amonowego\nZakres (0,05 – 10,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":27,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Ammonium nitrogen concentration Spectrophotometric method Range PN-ISO 7150-1:2002","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,05 – 10,0) mg/l"}],"search_zh":"水 氨氮浓度 分光光度法 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水"},{"_id":"6a5dc9bbf1c10c8ce825defd","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie azotu azotynowego","methodology_en":"Nitrite nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,010 – 0,30) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,010 – 0,30) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu azotynowego\nZakres (0,010 – 0,30) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie azotu azotynowego\nZakres (0,010 – 0,30) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda Stezenie azotu azotynowego\nZakres (0,010 – 0,30) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":28,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Nitrite nitrogen concentration Spectrophotometric method Range PN-EN 26777:1999","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,010 – 0,30) mg/l"}],"search_zh":"水 亚硝态氮浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水"},{"_id":"6a5dc9bbf1c10c8ce825defe","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie chlorków","methodology_en":"Chloride concentration","parameters":[{"name":"Zakres","range":"(5 − 3000) mg/l"}],"parameters_en":[{"name":"Range","range":"(5 − 3000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie chlorków\nZakres (5 − 3000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie chlorków\nZakres (5 − 3000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda Stezenie chlorkow\nZakres (5 − 3000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":29,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Chloride concentration Titrimetric method Range PN-ISO 9297:1994","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5 − 3000) mg/l"}],"search_zh":"水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水"},{"_id":"6a5dc9bbf1c10c8ce825deff","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie siarczanów","methodology_en":"Sulfate concentration","parameters":[{"name":"Zakres","range":"(10 − 500) mg/l"}],"parameters_en":[{"name":"Range","range":"(10 − 500) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie siarczanów\nZakres (10 − 500) mg/l\nMetoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie siarczanów\nZakres (10 − 500) mg/l\nMetoda wagowa PN-ISO 9280:2002 Woda Stezenie siarczanow\nZakres (10 − 500) mg/l\nMetoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":30,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Sulfate concentration Gravimetric method Range PN-ISO 9280:2002","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(10 − 500) mg/l"}],"search_zh":"水 硫酸盐浓度 重量法 范围 PN-ISO 9280:2002","technique_zh":"重量法","test_object_zh":"水"},{"_id":"6a5dc9bbf1c10c8ce825df00","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Chemiczne zapotrzebowanie tlenu (SP-ChZT)","methodology_en":"Chemical oxygen demand (SP-COD)","parameters":[{"name":"Zakres","range":"(5,0 − 150) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(5,0 − 150) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu (SP-ChZT)\nZakres (5,0 − 150) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Chemiczne zapotrzebowanie tlenu (SP-ChZT)\nZakres (5,0 − 150) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda Chemiczne zapotrzebowanie tlenu (SP-ChZT)\nZakres (5,0 − 150) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":31,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Chemical oxygen demand (SP-COD) Spectrophotometric method Range PN-ISO 15705:2005","parameters_zh":[{"name":"范围","range":"(5,0 − 150) mg/l O2"}],"search_zh":"水 化学需氧量（SP-COD） 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水","methodology_zh":"化学需氧量（SP-COD）"},{"_id":"6a5dc9bbf1c10c8ce825df01","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie fosforu ogólnego","methodology_en":"Total phosphorus concentration","parameters":[{"name":"Zakres","range":"(0,06 – 5,00) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,06 – 5,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,06 – 5,00) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 p. 7 + Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 p. 7 + Ap1:2010+Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie fosforu ogólnego\nZakres (0,06 – 5,00) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 p. 7 + Ap1:2010+Ap2:2010 Woda Stezenie fosforu ogolnego\nZakres (0,06 – 5,00) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 p. 7 + Ap1:2010+Ap2:2010","categories":["water"],"row_index":32,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Total phosphorus concentration Spectrophotometric method Range PN-EN ISO 6878:2006 p. 7 + Ap1:2010+Ap2:2010","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,06 – 5,00) mg/l"}],"search_zh":"水 总磷浓度 分光光度法 范围 PN-EN ISO 6878:2006 p. 7 + Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水"},{"_id":"6a5dc9bbf1c10c8ce825df02","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie żelaza ogólnego","methodology_en":"Total iron concentration","parameters":[{"name":"Zakres","range":"(10 – 10000) μg/l"}],"parameters_en":[{"name":"Range","range":"(10 – 10000) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie żelaza ogólnego\nZakres (10 – 10000) μg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001 + Ap1:2016-06","norm_bases":["PN-ISO 6332:2001 + Ap1:2016-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie żelaza ogólnego\nZakres (10 – 10000) μg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001 + Ap1:2016-06 Woda, scieki Stezenie zelaza ogolnego\nZakres (10 – 10000) μg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001 + Ap1:2016-06","categories":["water"],"row_index":33,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Total iron concentration Spectrophotometric method Range PN-ISO 6332:2001 + Ap1:2016-06","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(10 – 10000) μg/l"}],"search_zh":"水、废水 总铁浓度 分光光度法 范围 PN-ISO 6332:2001 + Ap1:2016-06","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a5dc9bbf1c10c8ce825df03","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie cyjanków wolnych","methodology_en":"Free cyanide concentration","parameters":[{"name":"Zakres","range":"(10 – 600) μg/l"}],"parameters_en":[{"name":"Range","range":"(10 – 600) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie cyjanków wolnych\nZakres (10 – 600) μg/l\nMetoda spektrofotometryczna","reference":"PL-PB-12 wydanie 02 z dnia 15.05.2014 r. | na podstawie testu kuwetowego Hach Lange Nr 315","norm_bases":["PL-PB-12 wydanie 02 z dnia 15.05.2014 r.","na podstawie testu kuwetowego Hach Lange Nr 315"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie cyjanków wolnych\nZakres (10 – 600) μg/l\nMetoda spektrofotometryczna PL-PB-12 wydanie 02 z dnia 15.05.2014 r. | na podstawie testu kuwetowego Hach Lange Nr 315 Woda, scieki Stezenie cyjankow wolnych\nZakres (10 – 600) μg/l\nMetoda spektrofotometryczna PL-PB-12 wydanie 02 z dnia 15.05.2014 r. | na podstawie testu kuwetowego Hach Lange Nr 315","categories":["water"],"row_index":34,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Free cyanide concentration Spectrophotometric method Range PL-PB-12 wydanie 02 z dnia 15.05.2014 r. | na podstawie testu kuwetowego Hach Lange Nr 315","parameters_zh":[{"name":"范围","range":"(10 – 600) μg/l"}],"search_zh":"水、废水 游离氰化物浓度 分光光度法 范围 PL-PB-12 wydanie 02 z dnia 15.05.2014 r. | na podstawie testu kuwetowego Hach Lange Nr 315","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"游离氰化物浓度"},{"_id":"6a5dc9bbf1c10c8ce825df04","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu (BZT5)","methodology_en":"Biochemical oxygen demand (BOD5)","parameters":[{"name":"Zakres","range":"(0,5 – 6) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(0,5 – 6) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu (BZT5)\nZakres (0,5 – 6) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu (BZT5)\nZakres (0,5 – 6) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Woda, scieki Biochemiczne zapotrzebowanie tlenu (BZT5)\nZakres (0,5 – 6) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":35,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Biochemical oxygen demand (BOD5) Electrochemical method Range PN-EN 1899-2:2002","parameters_zh":[{"name":"范围","range":"(0,5 – 6) mg/l O2"}],"search_zh":"水、废水 五日生化需氧量（BOD5） 电化学法 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"水、废水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a5dc9bbf1c10c8ce825df05","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie tlenu rozpuszczonego","methodology_en":"Dissolved oxygen concentration","parameters":[{"name":"Zakres","range":"(0,5 – 15) mg/l O2"},{"name":"% nasycenia tlenem"},{"name":"Zakres","range":"(5 – 150) %"}],"parameters_en":[{"name":"Range","range":"(0,5 – 15) mg/l O2"},{"name":"% oxygen saturation"},{"name":"Range","range":"(5 – 150) %"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Stężenie tlenu rozpuszczonego\nZakres:\nZakres (0,5 – 15) mg/l O2\n% nasycenia tlenem\nZakres (5 – 150) %\nMetoda elektrochemiczna","reference":"PN-EN ISO 5814:2013","norm_bases":["PN-EN ISO 5814:2013"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie tlenu rozpuszczonego\nZakres:\nZakres (0,5 – 15) mg/l O2\n% nasycenia tlenem\nZakres (5 – 150) %\nMetoda elektrochemiczna PN-EN ISO 5814:2013 Woda, scieki Stezenie tlenu rozpuszczonego\nZakres:\nZakres (0,5 – 15) mg/l O2\n% nasycenia tlenem\nZakres (5 – 150) %\nMetoda elektrochemiczna PN-EN ISO 5814:2013","categories":["water"],"row_index":36,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Dissolved oxygen concentration Electrochemical method Range % oxygen saturation Range PN-EN ISO 5814:2013","parameters_zh":[{"name":"范围","range":"(0,5 – 15) mg/l O2"},{"name":"% nasycenia tlenem"},{"name":"范围","range":"(5 – 150) %"}],"search_zh":"水、废水 溶解氧浓度 电化学法 范围 范围 PN-EN ISO 5814:2013","technique_zh":"电化学法","test_object_zh":"水、废水","methodology_zh":"溶解氧浓度"},{"_id":"6a5dc9bbf1c10c8ce825df06","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotu ogólnego (z obliczeń)","methodology_en":"Total nitrogen concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PL-PB-27 wydanie 03 z dnia 01.10.2019 r.","norm_bases":["PL-PB-27 wydanie 03 z dnia 01.10.2019 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotu ogólnego (z obliczeń) PL-PB-27 wydanie 03 z dnia 01.10.2019 r. Woda, scieki Stezenie azotu ogolnego (z obliczen) PL-PB-27 wydanie 03 z dnia 01.10.2019 r.","categories":["water"],"row_index":37,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Total nitrogen concentration (calculated) PL-PB-27 wydanie 03 z dnia 01.10.2019 r.","methodology_zh":"总氮浓度（计算值）","search_zh":"水、废水 总氮浓度（计算值） PL-PB-27 wydanie 03 z dnia 01.10.2019 r.","test_object_zh":"水、废水"},{"_id":"6a5dc9bbf1c10c8ce825df07","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[{"name":"Temperatura pobranej próbki ścieków"},{"name":"Zakres","range":"(1,0 – 60,0) °C"}],"parameters_en":[{"name":"Temperature of the collected wastewater sample"},{"name":"Range","range":"(1,0 – 60,0) °C"}],"technique":"Metoda manualna i automatyczna","techniques":["Metoda manualna i automatyczna"],"technique_en":"Manual and automatic method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura pobranej próbki ścieków\nZakres (1,0 – 60,0) °C\nMetoda manualna i automatyczna","reference":"PN-ISO 5667-10:2021-11 | PN-77/C-04584","norm_bases":["PN-ISO 5667-10:2021-11","PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura pobranej próbki ścieków\nZakres (1,0 – 60,0) °C\nMetoda manualna i automatyczna PN-ISO 5667-10:2021-11 | PN-77/C-04584 Scieki Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nTemperatura pobranej probki sciekow\nZakres (1,0 – 60,0) °C\nMetoda manualna i automatyczna PN-ISO 5667-10:2021-11 | PN-77/C-04584","categories":["water"],"row_index":38,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Sampling for chemical and physical testing Manual and automatic method Temperature of the collected wastewater sample Range PN-ISO 5667-10:2021-11 | PN-77/C-04584","methodology_zh":"化学与物理检测用样品采集","parameters_zh":[{"name":"所采废水样品的温度"},{"name":"范围","range":"(1,0 – 60,0) °C"}],"search_zh":"污水 化学与物理检测用样品采集 手工与自动法 所采废水样品的温度 范围 PN-ISO 5667-10:2021-11 | PN-77/C-04584","test_object_zh":"污水","technique_zh":"手工与自动法"},{"_id":"6a5dc9bbf1c10c8ce825df08","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"3,0 – 10,0"}],"parameters_en":[{"name":"Range","range":"3,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 3,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki pH\nZakres 3,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Scieki pH\nZakres 3,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":39,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"3,0 – 10,0"}],"search_zh":"污水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"污水"},{"_id":"6a5dc9bbf1c10c8ce825df09","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu BZT5","methodology_en":"Biochemical oxygen demand BOD5","parameters":[{"name":"Zakres","range":"(3,0 − 6000) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(3,0 − 6000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu BZT5\nZakres (3,0 − 6000) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu BZT5\nZakres (3,0 − 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Scieki Biochemiczne zapotrzebowanie tlenu BZT5\nZakres (3,0 − 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":40,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Biochemical oxygen demand BOD5 Electrochemical method Range PN-EN ISO 5815-1:2019-12","methodology_zh":"生化需氧量 BZT5（BOD5）","parameters_zh":[{"name":"范围","range":"(3,0 − 6000) mg/l O2"}],"search_zh":"污水 生化需氧量 BZT5（BOD5） 电化学法 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"污水"},{"_id":"6a5dc9bbf1c10c8ce825df0a","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu ogólnego","methodology_en":"Total nitrogen concentration","parameters":[{"name":"Zakres","range":"(1,00 − 100) mg/l"}],"parameters_en":[{"name":"Range","range":"(1,00 − 100) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego\nZakres (1,00 − 100) mg/l\nMetoda spektrofotometryczna","reference":"PL-PB-17 wydanie 04 z dnia 16.11.2017 r. | na podstawie testu kuwetowego Hach Lange Nr 138, Nr 238, Nr 338","norm_bases":["PL-PB-17 wydanie 04 z dnia 16.11.2017 r.","na podstawie testu kuwetowego Hach Lange Nr 138, Nr 238, Nr 338"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu ogólnego\nZakres (1,00 − 100) mg/l\nMetoda spektrofotometryczna PL-PB-17 wydanie 04 z dnia 16.11.2017 r. | na podstawie testu kuwetowego Hach Lange Nr 138, Nr 238, Nr 338 Scieki Stezenie azotu ogolnego\nZakres (1,00 − 100) mg/l\nMetoda spektrofotometryczna PL-PB-17 wydanie 04 z dnia 16.11.2017 r. | na podstawie testu kuwetowego Hach Lange Nr 138, Nr 238, Nr 338","categories":["water"],"row_index":41,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Total nitrogen concentration Spectrophotometric method Range PL-PB-17 wydanie 04 z dnia 16.11.2017 r. | na podstawie testu kuwetowego Hach Lange Nr 138, Nr 238, Nr 338","methodology_zh":"总氮浓度","parameters_zh":[{"name":"范围","range":"(1,00 − 100) mg/l"}],"search_zh":"污水 总氮浓度 分光光度法 范围 PL-PB-17 wydanie 04 z dnia 16.11.2017 r. | na podstawie testu kuwetowego Hach Lange Nr 138, Nr 238, Nr 338","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a5dc9bbf1c10c8ce825df0b","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie fosforu ogólnego","methodology_en":"Total phosphorus concentration","parameters":[{"name":"Zakres","range":"(0,06 – 80,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,06 – 80,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,06 – 80,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 p. 7 + Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 p. 7 + Ap1:2010+Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie fosforu ogólnego\nZakres (0,06 – 80,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 p. 7 + Ap1:2010+Ap2:2010 Scieki Stezenie fosforu ogolnego\nZakres (0,06 – 80,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 p. 7 + Ap1:2010+Ap2:2010","categories":["water"],"row_index":42,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Total phosphorus concentration Spectrophotometric method Range PN-EN ISO 6878:2006 p. 7 + Ap1:2010+Ap2:2010","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,06 – 80,0) mg/l"}],"search_zh":"污水 总磷浓度 分光光度法 范围 PN-EN ISO 6878:2006 p. 7 + Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a5dc9bbf1c10c8ce825df0c","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie ekstraktu eterowego","methodology_en":"Ether extract concentration","parameters":[{"name":"Zakres","range":"(5 − 200) mg/l"}],"parameters_en":[{"name":"Range","range":"(5 − 200) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie ekstraktu eterowego\nZakres (5 − 200) mg/l\nMetoda wagowa","reference":"PL-PB-05 wydanie 03 z dnia 15.09.2014 r.","norm_bases":["PL-PB-05 wydanie 03 z dnia 15.09.2014 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie ekstraktu eterowego\nZakres (5 − 200) mg/l\nMetoda wagowa PL-PB-05 wydanie 03 z dnia 15.09.2014 r. Scieki Stezenie ekstraktu eterowego\nZakres (5 − 200) mg/l\nMetoda wagowa PL-PB-05 wydanie 03 z dnia 15.09.2014 r.","categories":["water"],"row_index":43,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Ether extract concentration Gravimetric method Range PL-PB-05 wydanie 03 z dnia 15.09.2014 r.","parameters_zh":[{"name":"范围","range":"(5 − 200) mg/l"}],"search_zh":"污水 重量法 范围 PL-PB-05 wydanie 03 z dnia 15.09.2014 r.","technique_zh":"重量法","test_object_zh":"污水"},{"_id":"6a5dc9bbf1c10c8ce825df0d","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu Kjeldahla","methodology_en":"Kjeldahl nitrogen concentration","parameters":[{"name":"Zakres","range":"(1,0 − 500) mg/l"}],"parameters_en":[{"name":"Range","range":"(1,0 − 500) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie azotu Kjeldahla\nZakres (1,0 − 500) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu Kjeldahla\nZakres (1,0 − 500) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Scieki Stezenie azotu Kjeldahla\nZakres (1,0 − 500) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":44,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Kjeldahl nitrogen concentration Titrimetric method Range PN-EN 25663:2001","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(1,0 − 500) mg/l"}],"search_zh":"污水 凯氏氮浓度 滴定法 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"污水"},{"_id":"6a5dc9bbf1c10c8ce825df0e","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie chromu (VI)","methodology_en":"Chromium(VI) concentration","parameters":[{"name":"Zakres","range":"(0,02 − 7,5) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,02 − 7,5) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie chromu (VI)\nZakres (0,02 − 7,5) mg/l\nMetoda spektrofotometryczna","reference":"PN-77/C-04604/08","norm_bases":["PN-77/C-04604/08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie chromu (VI)\nZakres (0,02 − 7,5) mg/l\nMetoda spektrofotometryczna PN-77/C-04604/08 Scieki Stezenie chromu (VI)\nZakres (0,02 − 7,5) mg/l\nMetoda spektrofotometryczna PN-77/C-04604/08","categories":["water"],"row_index":45,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Chromium(VI) concentration Spectrophotometric method Range PN-77/C-04604/08","parameters_zh":[{"name":"范围","range":"(0,02 − 7,5) mg/l"}],"search_zh":"污水 六价铬浓度 分光光度法 范围 PN-77/C-04604/08","technique_zh":"分光光度法","test_object_zh":"污水","methodology_zh":"六价铬浓度"},{"_id":"6a5dc9bbf1c10c8ce825df0f","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Przewodność elektryczna właściwa","methodology_en":"Electrical conductivity","parameters":[{"name":"Zakres","range":"(5 − 5000) μS/cm"}],"parameters_en":[{"name":"Range","range":"(5 − 5000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"technique_en":"Conductometric method","computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa\nZakres (5 − 5000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Przewodność elektryczna właściwa\nZakres (5 − 5000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Scieki Przewodnosc elektryczna wlasciwa\nZakres (5 − 5000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":46,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Electrical conductivity Conductometric method Range PN-EN 27888:1999","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(5 − 5000) μS/cm"}],"search_zh":"污水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"污水"},{"_id":"6a5dc9bbf1c10c8ce825df10","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Zawiesiny ogólne","methodology_en":"Total suspended solids (TSS)","parameters":[{"name":"Zakres","range":"(2,0 − 2000) mg/l"}],"parameters_en":[{"name":"Range","range":"(2,0 − 2000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawiesiny ogólne\nZakres (2,0 − 2000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Zawiesiny ogólne\nZakres (2,0 − 2000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Scieki Zawiesiny ogolne\nZakres (2,0 − 2000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":47,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 − 2000) mg/l"}],"search_zh":"污水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"污水"},{"_id":"6a5dc9bbf1c10c8ce825df11","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu amonowego","methodology_en":"Ammonium nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,05 – 80,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,05 – 80,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego\nZakres (0,05 – 80,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu amonowego\nZakres (0,05 – 80,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Scieki Stezenie azotu amonowego\nZakres (0,05 – 80,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":48,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Ammonium nitrogen concentration Spectrophotometric method Range PN-ISO 7150-1:2002","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,05 – 80,0) mg/l"}],"search_zh":"污水 氨氮浓度 分光光度法 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a5dc9bbf1c10c8ce825df12","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu azotynowego","methodology_en":"Nitrite nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,010 − 10) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,010 − 10) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu azotynowego\nZakres (0,010 − 10) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu azotynowego\nZakres (0,010 − 10) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Scieki Stezenie azotu azotynowego\nZakres (0,010 − 10) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":49,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Nitrite nitrogen concentration Spectrophotometric method Range PN-EN 26777:1999","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,010 − 10) mg/l"}],"search_zh":"污水 亚硝态氮浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a5dc9bbf1c10c8ce825df13","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu azotanowego","methodology_en":"Nitrate nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,04 − 35,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,04 − 35,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu azotanowego\nZakres (0,04 − 35,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu azotanowego\nZakres (0,04 − 35,0) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08 Scieki Stezenie azotu azotanowego\nZakres (0,04 − 35,0) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":50,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Nitrate nitrogen concentration Spectrophotometric method Range PN-82/C-04576/08","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,04 − 35,0) mg/l"}],"search_zh":"污水 硝态氮浓度 分光光度法 范围 PN-82/C-04576/08","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a5dc9bbf1c10c8ce825df14","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie chlorków","methodology_en":"Chloride concentration","parameters":[{"name":"Zakres","range":"(5 − 3000) mg/l"}],"parameters_en":[{"name":"Range","range":"(5 − 3000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie chlorków\nZakres (5 − 3000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie chlorków\nZakres (5 − 3000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Scieki Stezenie chlorkow\nZakres (5 − 3000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":51,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Chloride concentration Titrimetric method Range PN-ISO 9297:1994","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5 − 3000) mg/l"}],"search_zh":"污水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"污水"},{"_id":"6a5dc9bbf1c10c8ce825df15","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie siarczanów","methodology_en":"Sulfate concentration","parameters":[{"name":"Zakres","range":"(10 − 500) mg/l"}],"parameters_en":[{"name":"Range","range":"(10 − 500) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie siarczanów\nZakres (10 − 500) mg/l\nMetoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie siarczanów\nZakres (10 − 500) mg/l\nMetoda wagowa PN-ISO 9280:2002 Scieki Stezenie siarczanow\nZakres (10 − 500) mg/l\nMetoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":52,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Sulfate concentration Gravimetric method Range PN-ISO 9280:2002","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(10 − 500) mg/l"}],"search_zh":"污水 硫酸盐浓度 重量法 范围 PN-ISO 9280:2002","technique_zh":"重量法","test_object_zh":"污水"},{"_id":"6a5dc9bbf1c10c8ce825df16","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Chemiczne zapotrzebowanie tlenu (SP-ChZT)","methodology_en":"Chemical oxygen demand (SP-COD)","parameters":[{"name":"Zakres","range":"(5,0 − 10 000) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(5,0 − 10 000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu (SP-ChZT)\nZakres (5,0 − 10 000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Chemiczne zapotrzebowanie tlenu (SP-ChZT)\nZakres (5,0 − 10 000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Scieki Chemiczne zapotrzebowanie tlenu (SP-ChZT)\nZakres (5,0 − 10 000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":53,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Chemical oxygen demand (SP-COD) Spectrophotometric method Range PN-ISO 15705:2005","parameters_zh":[{"name":"范围","range":"(5,0 − 10 000) mg/l O2"}],"search_zh":"污水 化学需氧量（SP-COD） 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"污水","methodology_zh":"化学需氧量（SP-COD）"},{"_id":"6a5dc9bbf1c10c8ce825df17","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Pobieranie próbek do badań chemicznych, fizycznych, mikrobiologicznych i biologicznych","methodology_en":"Sampling for chemical, physical, microbiological and biological testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych, fizycznych, mikrobiologicznych i biologicznych","reference":"PN-EN ISO 5667-13:2011 z wyłączeniem p. 6.3.3, 6.3.4, 6.3.5, 6.3.10","norm_bases":["PN-EN ISO 5667-13:2011 z wyłączeniem p. 6.3.3, 6.3.4, 6.3.5, 6.3.10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Pobieranie próbek do badań chemicznych, fizycznych, mikrobiologicznych i biologicznych PN-EN ISO 5667-13:2011 z wyłączeniem p. 6.3.3, 6.3.4, 6.3.5, 6.3.10 Osady sciekowe Pobieranie probek do badan chemicznych, fizycznych, mikrobiologicznych i biologicznych PN-EN ISO 5667-13:2011 z wylaczeniem p. 6.3.3, 6.3.4, 6.3.5, 6.3.10","categories":["water","microbiology"],"row_index":54,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge Sampling for chemical, physical, microbiological and biological testing PN-EN ISO 5667-13:2011 z wyłączeniem p. 6.3.3, 6.3.4, 6.3.5, 6.3.10","search_zh":"污泥 用于化学、物理、微生物与生物检验的采样 PN-EN ISO 5667-13:2011 z wyłączeniem p. 6.3.3, 6.3.4, 6.3.5, 6.3.10","test_object_zh":"污泥","methodology_zh":"用于化学、物理、微生物与生物检验的采样"},{"_id":"6a5dc9bbf1c10c8ce825df18","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"pH – w H2O","methodology_en":"pH – in H2O","parameters":[{"name":"Zakres","range":"3,0 − 12,0"}],"parameters_en":[{"name":"Range","range":"3,0 − 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH – w H2O\nZakres 3,0 − 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe pH – w H2O\nZakres 3,0 − 12,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 Osady sciekowe pH – w H2O\nZakres 3,0 − 12,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["water"],"row_index":55,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge pH – in H2O Potentiometric method Range PN-EN ISO 10390:2022-09","parameters_zh":[{"name":"范围","range":"3,0 − 12,0"}],"search_zh":"污泥 pH — 于 H2O 中 电位法 范围 PN-EN ISO 10390:2022-09","technique_zh":"电位法","test_object_zh":"污泥","methodology_zh":"pH — 于 H2O 中"},{"_id":"6a5dc9bbf1c10c8ce825df19","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Zawartość azotu ogólnego Kjeldahla","methodology_en":"Total Kjeldahl nitrogen content","parameters":[{"name":"Zakres","range":"(0,25 − 13,0) %"}],"parameters_en":[{"name":"Range","range":"(0,25 − 13,0) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Zawartość azotu ogólnego Kjeldahla\nZakres (0,25 − 13,0) %\nMetoda miareczkowa","reference":"PN-EN 13342:2002","norm_bases":["PN-EN 13342:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Zawartość azotu ogólnego Kjeldahla\nZakres (0,25 − 13,0) %\nMetoda miareczkowa PN-EN 13342:2002 Osady sciekowe Zawartosc azotu ogolnego Kjeldahla\nZakres (0,25 − 13,0) %\nMetoda miareczkowa PN-EN 13342:2002","categories":["water"],"row_index":56,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge Total Kjeldahl nitrogen content Titrimetric method Range PN-EN 13342:2002","parameters_zh":[{"name":"范围","range":"(0,25 − 13,0) %"}],"search_zh":"污泥 凯氏总氮含量 滴定法 范围 PN-EN 13342:2002","technique_zh":"滴定法","test_object_zh":"污泥","methodology_zh":"凯氏总氮含量"},{"_id":"6a5dc9bbf1c10c8ce825df1a","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Zawartość suchej masy","methodology_en":"Dry matter content","parameters":[{"name":"Zakres","range":"(1,00 − 80,0) %"}],"parameters_en":[{"name":"Range","range":"(1,00 − 80,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość suchej masy\nZakres (1,00 − 80,0) %\nMetoda wagowa","reference":"PN-EN 15934:2013-02 z wyłączeniem metody B","norm_bases":["PN-EN 15934:2013-02 z wyłączeniem metody B"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Zawartość suchej masy\nZakres (1,00 − 80,0) %\nMetoda wagowa PN-EN 15934:2013-02 z wyłączeniem metody B Osady sciekowe Zawartosc suchej masy\nZakres (1,00 − 80,0) %\nMetoda wagowa PN-EN 15934:2013-02 z wylaczeniem metody B","categories":["water"],"row_index":57,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge Dry matter content Gravimetric method Range PN-EN 15934:2013-02 z wyłączeniem metody B","parameters_zh":[{"name":"范围","range":"(1,00 − 80,0) %"}],"search_zh":"污泥 干物质含量 重量法 范围 PN-EN 15934:2013-02 z wyłączeniem metody B","technique_zh":"重量法","test_object_zh":"污泥","methodology_zh":"干物质含量"},{"_id":"6a5dc9bbf1c10c8ce825df1b","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Zawartość wody (z obliczeń)","methodology_en":"Water content (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wody (z obliczeń)","reference":"PN-EN 15934:2013-02 z wyłączeniem metody B","norm_bases":["PN-EN 15934:2013-02 z wyłączeniem metody B"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Zawartość wody (z obliczeń) PN-EN 15934:2013-02 z wyłączeniem metody B Osady sciekowe Zawartosc wody (z obliczen) PN-EN 15934:2013-02 z wylaczeniem metody B","categories":["water"],"row_index":58,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge Water content (calculated) PN-EN 15934:2013-02 z wyłączeniem metody B","search_zh":"污泥 水分含量（计算值） PN-EN 15934:2013-02 z wyłączeniem metody B","test_object_zh":"污泥","methodology_zh":"水分含量（计算值）"},{"_id":"6a5dc9bbf1c10c8ce825df1c","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Strata przy prażeniu (substancje organiczne)","methodology_en":"Loss on ignition (organic matter)","parameters":[{"name":"Zakres","range":"(10,0 − 85,0) %"}],"parameters_en":[{"name":"Range","range":"(10,0 − 85,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Strata przy prażeniu (substancje organiczne)\nZakres (10,0 − 85,0) %\nMetoda wagowa","reference":"PN-EN 15935:2022-01","norm_bases":["PN-EN 15935:2022-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Strata przy prażeniu (substancje organiczne)\nZakres (10,0 − 85,0) %\nMetoda wagowa PN-EN 15935:2022-01 Osady sciekowe Strata przy prazeniu (substancje organiczne)\nZakres (10,0 − 85,0) %\nMetoda wagowa PN-EN 15935:2022-01","categories":["water"],"row_index":59,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge Loss on ignition (organic matter) Gravimetric method Range PN-EN 15935:2022-01","parameters_zh":[{"name":"范围","range":"(10,0 − 85,0) %"}],"search_zh":"污泥 烧失量（有机物质） 重量法 范围 PN-EN 15935:2022-01","technique_zh":"重量法","test_object_zh":"污泥","methodology_zh":"烧失量（有机物质）"},{"_id":"6a5dc9bbf1c10c8ce825df1d","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Pozostałość po prażeniu (substancje mineralne) (z obliczeń)","methodology_en":"Residue on ignition (mineral substances) (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pozostałość po prażeniu (substancje mineralne) (z obliczeń)","reference":"PN-EN 15935:2022-01","norm_bases":["PN-EN 15935:2022-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Pozostałość po prażeniu (substancje mineralne) (z obliczeń) PN-EN 15935:2022-01 Osady sciekowe Pozostalosc po prazeniu (substancje mineralne) (z obliczen) PN-EN 15935:2022-01","categories":["water"],"row_index":60,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge Residue on ignition (mineral substances) (calculated) PN-EN 15935:2022-01","search_zh":"污泥 灼烧残渣（矿物质）（由计算得出） PN-EN 15935:2022-01","test_object_zh":"污泥","methodology_zh":"灼烧残渣（矿物质）（由计算得出）"},{"_id":"6a5dc9bbf1c10c8ce825df1e","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Osady, środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby","test_object_en":"Sludges, plant cultivation aids: - soil improvers","methodology":"Zawartość azotu amonowego","methodology_en":"Ammonium nitrogen content","parameters":[{"name":"Zakres","range":"(0,10 − 9,00) %"}],"parameters_en":[{"name":"Range","range":"(0,10 − 9,00) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Zawartość azotu amonowego\nZakres (0,10 − 9,00) %\nMetoda miareczkowa","reference":"PN-75/C-04576-15","norm_bases":["PN-75/C-04576-15"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady, środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby Zawartość azotu amonowego\nZakres (0,10 − 9,00) %\nMetoda miareczkowa PN-75/C-04576-15 Osady, srodki wspomagajace uprawe roslin: - srodki poprawiajace wlasciwosci gleby Zawartosc azotu amonowego\nZakres (0,10 − 9,00) %\nMetoda miareczkowa PN-75/C-04576-15","categories":["water"],"row_index":61,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sludges, plant cultivation aids: - soil improvers Ammonium nitrogen content Titrimetric method Range PN-75/C-04576-15","parameters_zh":[{"name":"范围","range":"(0,10 − 9,00) %"}],"search_zh":"氨氮含量 滴定法 范围 PN-75/C-04576-15","technique_zh":"滴定法","methodology_zh":"氨氮含量"},{"_id":"6a5dc9bbf1c10c8ce825df1f","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Osady, środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby","test_object_en":"Sludges, plant cultivation aids: - soil improvers","methodology":"Zawartość fosforu ogólnego","methodology_en":"Total phosphorus content","parameters":[{"name":"Zakres","range":"(0,10 − 6,0) %"}],"parameters_en":[{"name":"Range","range":"(0,10 − 6,0) %"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Zawartość fosforu ogólnego\nZakres (0,10 − 6,0) %\nMetoda spektrofotometryczna","reference":"PN-EN 14672:2006","norm_bases":["PN-EN 14672:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady, środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby Zawartość fosforu ogólnego\nZakres (0,10 − 6,0) %\nMetoda spektrofotometryczna PN-EN 14672:2006 Osady, srodki wspomagajace uprawe roslin: - srodki poprawiajace wlasciwosci gleby Zawartosc fosforu ogolnego\nZakres (0,10 − 6,0) %\nMetoda spektrofotometryczna PN-EN 14672:2006","categories":["water"],"row_index":62,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sludges, plant cultivation aids: - soil improvers Total phosphorus content Spectrophotometric method Range PN-EN 14672:2006","parameters_zh":[{"name":"范围","range":"(0,10 − 6,0) %"}],"search_zh":"总磷含量 分光光度法 范围 PN-EN 14672:2006","technique_zh":"分光光度法","methodology_zh":"总磷含量"},{"_id":"6a5dc9bbf1c10c8ce825df20","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby","test_object_en":"Plant cultivation aids: - soil improvers","methodology":"Pobieranie próbek do badań chemicznych, fizycznych, mikrobiologicznych i biologicznych","methodology_en":"Sampling for chemical, physical, microbiological and biological testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych, fizycznych, mikrobiologicznych i biologicznych","reference":"PN-ISO 12579:2013","norm_bases":["PN-ISO 12579:2013"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby Pobieranie próbek do badań chemicznych, fizycznych, mikrobiologicznych i biologicznych PN-ISO 12579:2013 Srodki wspomagajace uprawe roslin: - srodki poprawiajace wlasciwosci gleby Pobieranie probek do badan chemicznych, fizycznych, mikrobiologicznych i biologicznych PN-ISO 12579:2013","categories":["microbiology"],"row_index":63,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Plant cultivation aids: - soil improvers Sampling for chemical, physical, microbiological and biological testing PN-ISO 12579:2013","search_zh":"植物栽培辅助制剂：－ 土壤改良剂 用于化学、物理、微生物与生物检验的采样 PN-ISO 12579:2013","test_object_zh":"植物栽培辅助制剂：－ 土壤改良剂","methodology_zh":"用于化学、物理、微生物与生物检验的采样"},{"_id":"6a5dc9bbf1c10c8ce825df21","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby","test_object_en":"Plant cultivation aids: - soil improvers","methodology":"Zawartość azotu całkowitego","methodology_en":"Total nitrogen content","parameters":[{"name":"Zakres","range":"(1,00 − 7,00) %"}],"parameters_en":[{"name":"Range","range":"(1,00 − 7,00) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Zawartość azotu całkowitego\nZakres (1,00 − 7,00) %\nMetoda miareczkowa","reference":"PL-PB-28 wydanie 04 z dnia 20.08.2019 r.","norm_bases":["PL-PB-28 wydanie 04 z dnia 20.08.2019 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby Zawartość azotu całkowitego\nZakres (1,00 − 7,00) %\nMetoda miareczkowa PL-PB-28 wydanie 04 z dnia 20.08.2019 r. Srodki wspomagajace uprawe roslin: - srodki poprawiajace wlasciwosci gleby Zawartosc azotu calkowitego\nZakres (1,00 − 7,00) %\nMetoda miareczkowa PL-PB-28 wydanie 04 z dnia 20.08.2019 r.","categories":["other"],"row_index":64,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Plant cultivation aids: - soil improvers Total nitrogen content Titrimetric method Range PL-PB-28 wydanie 04 z dnia 20.08.2019 r.","parameters_zh":[{"name":"范围","range":"(1,00 − 7,00) %"}],"search_zh":"植物栽培辅助制剂：－ 土壤改良剂 总氮含量 滴定法 范围 PL-PB-28 wydanie 04 z dnia 20.08.2019 r.","technique_zh":"滴定法","methodology_zh":"总氮含量","test_object_zh":"植物栽培辅助制剂：－ 土壤改良剂"},{"_id":"6a5dc9bbf1c10c8ce825df22","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby","test_object_en":"Plant cultivation aids: - soil improvers","methodology":"Zawartość suchej masy","methodology_en":"Dry matter content","parameters":[{"name":"Zakres","range":"(37,0 − 97,0) %"}],"parameters_en":[{"name":"Range","range":"(37,0 − 97,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość suchej masy\nZakres (37,0 − 97,0) %\nMetoda wagowa","reference":"PN-EN 13040:2009","norm_bases":["PN-EN 13040:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby Zawartość suchej masy\nZakres (37,0 − 97,0) %\nMetoda wagowa PN-EN 13040:2009 Srodki wspomagajace uprawe roslin: - srodki poprawiajace wlasciwosci gleby Zawartosc suchej masy\nZakres (37,0 − 97,0) %\nMetoda wagowa PN-EN 13040:2009","categories":["other"],"row_index":65,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Plant cultivation aids: - soil improvers Dry matter content Gravimetric method Range PN-EN 13040:2009","parameters_zh":[{"name":"范围","range":"(37,0 − 97,0) %"}],"search_zh":"植物栽培辅助制剂：－ 土壤改良剂 干物质含量 重量法 范围 PN-EN 13040:2009","technique_zh":"重量法","methodology_zh":"干物质含量","test_object_zh":"植物栽培辅助制剂：－ 土壤改良剂"},{"_id":"6a5dc9bbf1c10c8ce825df23","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby","test_object_en":"Plant cultivation aids: - soil improvers","methodology":"Zawartość wody (z obliczeń)","methodology_en":"Water content (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wody (z obliczeń)","reference":"PN-EN 13040:2009","norm_bases":["PN-EN 13040:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby Zawartość wody (z obliczeń) PN-EN 13040:2009 Srodki wspomagajace uprawe roslin: - srodki poprawiajace wlasciwosci gleby Zawartosc wody (z obliczen) PN-EN 13040:2009","categories":["water"],"row_index":66,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Plant cultivation aids: - soil improvers Water content (calculated) PN-EN 13040:2009","methodology_zh":"水分含量（计算值）","search_zh":"植物栽培辅助制剂：－ 土壤改良剂 水分含量（计算值） PN-EN 13040:2009","test_object_zh":"植物栽培辅助制剂：－ 土壤改良剂"},{"_id":"6a5dc9bbf1c10c8ce825df24","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby","test_object_en":"Plant cultivation aids: - soil improvers","methodology":"Strata przy prażeniu (substancje organiczne)","methodology_en":"Loss on ignition (organic matter)","parameters":[{"name":"Zakres","range":"(18,0 − 62,0) %"}],"parameters_en":[{"name":"Range","range":"(18,0 − 62,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Strata przy prażeniu (substancje organiczne)\nZakres (18,0 − 62,0) %\nMetoda wagowa","reference":"PN-EN 13039:2011","norm_bases":["PN-EN 13039:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby Strata przy prażeniu (substancje organiczne)\nZakres (18,0 − 62,0) %\nMetoda wagowa PN-EN 13039:2011 Srodki wspomagajace uprawe roslin: - srodki poprawiajace wlasciwosci gleby Strata przy prazeniu (substancje organiczne)\nZakres (18,0 − 62,0) %\nMetoda wagowa PN-EN 13039:2011","categories":["other"],"row_index":67,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Plant cultivation aids: - soil improvers Loss on ignition (organic matter) Gravimetric method Range PN-EN 13039:2011","parameters_zh":[{"name":"范围","range":"(18,0 − 62,0) %"}],"search_zh":"植物栽培辅助制剂：－ 土壤改良剂 烧失量（有机物质） 重量法 范围 PN-EN 13039:2011","technique_zh":"重量法","test_object_zh":"植物栽培辅助制剂：－ 土壤改良剂","methodology_zh":"烧失量（有机物质）"},{"_id":"6a5dc9bbf1c10c8ce825df25","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby","test_object_en":"Plant cultivation aids: - soil improvers","methodology":"Pozostałość po prażeniu (substancje mineralne) (z obliczeń)","methodology_en":"Residue on ignition (mineral substances) (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pozostałość po prażeniu (substancje mineralne) (z obliczeń)","reference":"PN-EN 13039:2011","norm_bases":["PN-EN 13039:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby Pozostałość po prażeniu (substancje mineralne) (z obliczeń) PN-EN 13039:2011 Srodki wspomagajace uprawe roslin: - srodki poprawiajace wlasciwosci gleby Pozostalosc po prazeniu (substancje mineralne) (z obliczen) PN-EN 13039:2011","categories":["other"],"row_index":68,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Plant cultivation aids: - soil improvers Residue on ignition (mineral substances) (calculated) PN-EN 13039:2011","search_zh":"植物栽培辅助制剂：－ 土壤改良剂 灼烧残渣（矿物质）（由计算得出） PN-EN 13039:2011","test_object_zh":"植物栽培辅助制剂：－ 土壤改良剂","methodology_zh":"灼烧残渣（矿物质）（由计算得出）"},{"_id":"6a5dc9bbf1c10c8ce825df26","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-R-04031:1997","norm_bases":["PN-R-04031:1997"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Pobieranie próbek do badań chemicznych i fizycznych PN-R-04031:1997 Gleba Pobieranie probek do badan chemicznych i fizycznych PN-R-04031:1997","categories":["environment"],"row_index":69,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Soil Sampling for chemical and physical testing PN-R-04031:1997","methodology_zh":"化学与物理检测用样品采集","search_zh":"土壤 化学与物理检测用样品采集 PN-R-04031:1997","test_object_zh":"土壤"},{"_id":"6a5dc9bbf1c10c8ce825df27","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"pH – w H2O","methodology_en":"pH – in H2O","parameters":[{"name":"Zakres","range":"3,0 − 10,0"}],"parameters_en":[{"name":"Range","range":"3,0 − 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH – w H2O\nZakres 3,0 − 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba pH – w H2O\nZakres 3,0 − 10,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 Gleba pH – w H2O\nZakres 3,0 − 10,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["environment"],"row_index":70,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Soil pH – in H2O Potentiometric method Range PN-EN ISO 10390:2022-09","parameters_zh":[{"name":"范围","range":"3,0 − 10,0"}],"search_zh":"土壤 pH — 于 H2O 中 电位法 范围 PN-EN ISO 10390:2022-09","technique_zh":"电位法","test_object_zh":"土壤","methodology_zh":"pH — 于 H2O 中"},{"_id":"6a5dc9bbf1c10c8ce825df28","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Zawartość suchej masy","methodology_en":"Dry matter content","parameters":[{"name":"Zakres","range":"(75,0 − 99,5) %"}],"parameters_en":[{"name":"Range","range":"(75,0 − 99,5) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość suchej masy\nZakres (75,0 − 99,5) %\nMetoda wagowa","reference":"PN-EN 15934:2013-02 z wyłączeniem metody B","norm_bases":["PN-EN 15934:2013-02 z wyłączeniem metody B"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Zawartość suchej masy\nZakres (75,0 − 99,5) %\nMetoda wagowa PN-EN 15934:2013-02 z wyłączeniem metody B Gleba Zawartosc suchej masy\nZakres (75,0 − 99,5) %\nMetoda wagowa PN-EN 15934:2013-02 z wylaczeniem metody B","categories":["environment"],"row_index":71,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Soil Dry matter content Gravimetric method Range PN-EN 15934:2013-02 z wyłączeniem metody B","parameters_zh":[{"name":"范围","range":"(75,0 − 99,5) %"}],"search_zh":"土壤 干物质含量 重量法 范围 PN-EN 15934:2013-02 z wyłączeniem metody B","technique_zh":"重量法","test_object_zh":"土壤","methodology_zh":"干物质含量"},{"_id":"6a5dc9bbf1c10c8ce825df29","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Zawartość wody (z obliczeń)","methodology_en":"Water content (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wody (z obliczeń)","reference":"PN-EN 15934:2013-02 z wyłączeniem metody B","norm_bases":["PN-EN 15934:2013-02 z wyłączeniem metody B"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Zawartość wody (z obliczeń) PN-EN 15934:2013-02 z wyłączeniem metody B Gleba Zawartosc wody (z obliczen) PN-EN 15934:2013-02 z wylaczeniem metody B","categories":["water","environment"],"row_index":72,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Soil Water content (calculated) PN-EN 15934:2013-02 z wyłączeniem metody B","search_zh":"土壤 水分含量（计算值） PN-EN 15934:2013-02 z wyłączeniem metody B","test_object_zh":"土壤","methodology_zh":"水分含量（计算值）"},{"_id":"6a5dc9bbf1c10c8ce825df2a","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Strata przy prażeniu (substancje organiczne)","methodology_en":"Loss on ignition (organic matter)","parameters":[{"name":"Zakres","range":"(1,50 − 18,0) %"}],"parameters_en":[{"name":"Range","range":"(1,50 − 18,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Strata przy prażeniu (substancje organiczne)\nZakres (1,50 − 18,0) %\nMetoda wagowa","reference":"PN-EN 15935:2022-01","norm_bases":["PN-EN 15935:2022-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Strata przy prażeniu (substancje organiczne)\nZakres (1,50 − 18,0) %\nMetoda wagowa PN-EN 15935:2022-01 Gleba Strata przy prazeniu (substancje organiczne)\nZakres (1,50 − 18,0) %\nMetoda wagowa PN-EN 15935:2022-01","categories":["environment"],"row_index":73,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Soil Loss on ignition (organic matter) Gravimetric method Range PN-EN 15935:2022-01","parameters_zh":[{"name":"范围","range":"(1,50 − 18,0) %"}],"search_zh":"土壤 烧失量（有机物质） 重量法 范围 PN-EN 15935:2022-01","technique_zh":"重量法","test_object_zh":"土壤","methodology_zh":"烧失量（有机物质）"},{"_id":"6a5dc9bbf1c10c8ce825df2b","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Pozostałość po prażeniu (substancje mineralne) (z obliczeń)","methodology_en":"Residue on ignition (mineral substances) (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pozostałość po prażeniu (substancje mineralne) (z obliczeń)","reference":"PN-EN 15935:2022-01","norm_bases":["PN-EN 15935:2022-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Pozostałość po prażeniu (substancje mineralne) (z obliczeń) PN-EN 15935:2022-01 Gleba Pozostalosc po prazeniu (substancje mineralne) (z obliczen) PN-EN 15935:2022-01","categories":["environment"],"row_index":74,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Soil Residue on ignition (mineral substances) (calculated) PN-EN 15935:2022-01","search_zh":"土壤 灼烧残渣（矿物质）（由计算得出） PN-EN 15935:2022-01","test_object_zh":"土壤","methodology_zh":"灼烧残渣（矿物质）（由计算得出）"},{"_id":"6a5dc9bbf1c10c8ce825df2c","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Gleba mineralna","test_object_en":"Mineral soil","methodology":"Zawartość fosforu przyswajalnego","methodology_en":"Available phosphorus content","parameters":[{"name":"Zakres","range":"(3,2 − 45) mg P2O5/100 g"}],"parameters_en":[{"name":"Range","range":"(3,2 − 45) mg P2O5/100 g"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Zawartość fosforu przyswajalnego\nZakres (3,2 − 45) mg P2O5/100 g\nMetoda spektrofotometryczna","reference":"PN-R-04023:1996","norm_bases":["PN-R-04023:1996"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba mineralna Zawartość fosforu przyswajalnego\nZakres (3,2 − 45) mg P2O5/100 g\nMetoda spektrofotometryczna PN-R-04023:1996 Gleba mineralna Zawartosc fosforu przyswajalnego\nZakres (3,2 − 45) mg P2O5/100 g\nMetoda spektrofotometryczna PN-R-04023:1996","categories":["environment"],"row_index":75,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Mineral soil Available phosphorus content Spectrophotometric method Range PN-R-04023:1996","parameters_zh":[{"name":"范围","range":"(3,2 − 45) mg P2O5/100 g"}],"search_zh":"矿质土壤 有效磷含量 分光光度法 范围 PN-R-04023:1996","technique_zh":"分光光度法","test_object_zh":"矿质土壤","methodology_zh":"有效磷含量"},{"_id":"6a5dc9bbf1c10c8ce825df2d","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Gazy składowiskowe","test_object_en":"Landfill gases","methodology":"Stężenie: metanu, dwutlenku węgla","methodology_en":"Concentration of: methane, carbon dioxide","parameters":[{"name":"CH4","range":"(0,7 − 70,0) %"},{"name":"CO2","range":"(0,6 − 25,0) %"},{"name":"Stężenie tlenu O2","range":"(0,5 – 20,0) %"}],"parameters_en":[{"name":"CH4","range":"(0,7 − 70,0) %"},{"name":"CO2","range":"(0,6 − 25,0) %"},{"name":"Oxygen concentration O2","range":"(0,5 – 20,0) %"}],"technique":"Metoda NDIR; Metoda elektrochemiczna","techniques":["Metoda NDIR","Metoda elektrochemiczna"],"technique_en":"NDIR method; Electrochemical method","computed":[],"computed_en":[],"activity":"Stężenie: metanu, dwutlenku węgla\nZakres:\nCH4 (0,7 − 70,0) %\nCO2 (0,6 − 25,0) %\nStężenie tlenu O2 (0,5 – 20,0) %\nMetoda NDIR; Metoda elektrochemiczna","reference":"PL-PB-26 wydanie 04 z dnia 24.11.2020 r.","norm_bases":["PL-PB-26 wydanie 04 z dnia 24.11.2020 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy składowiskowe Stężenie: metanu, dwutlenku węgla\nZakres:\nCH4 (0,7 − 70,0) %\nCO2 (0,6 − 25,0) %\nStężenie tlenu O2 (0,5 – 20,0) %\nMetoda NDIR; Metoda elektrochemiczna PL-PB-26 wydanie 04 z dnia 24.11.2020 r. Gazy skladowiskowe Stezenie: metanu, dwutlenku wegla\nZakres:\nCH4 (0,7 − 70,0) %\nCO2 (0,6 − 25,0) %\nStezenie tlenu O2 (0,5 – 20,0) %\nMetoda NDIR; Metoda elektrochemiczna PL-PB-26 wydanie 04 z dnia 24.11.2020 r.","categories":["other"],"row_index":76,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Landfill gases Concentration of: methane, carbon dioxide NDIR method; Electrochemical method CH4 CO2 Oxygen concentration O2 PL-PB-26 wydanie 04 z dnia 24.11.2020 r.","parameters_zh":[{"name":"CH4","range":"(0,7 − 70,0) %"},{"name":"CO2","range":"(0,6 − 25,0) %"},{"name":"Stężenie tlenu O2","range":"(0,5 – 20,0) %"}],"search_zh":"填埋场气体 CO2 PL-PB-26 wydanie 04 z dnia 24.11.2020 r.","test_object_zh":"填埋场气体"},{"_id":"6a5dc9bbf1c10c8ce825df2e","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Gazy składowiskowe","test_object_en":"Landfill gases","methodology":"Prędkość przepływu gazu","methodology_en":"Gas flow velocity","parameters":[{"name":"Zakres","range":"(1,0 – 5,0) m/s"},{"name":"Emisja CH4 i CO2 (z obliczeń)"}],"parameters_en":[{"name":"Range","range":"(1,0 – 5,0) m/s"},{"name":"CH4 and CO2 emission (calculated)"}],"technique":"Metoda termoanemometryczna","techniques":["Metoda termoanemometryczna"],"technique_en":"Thermoanemometric method","computed":[],"computed_en":[],"activity":"Prędkość przepływu gazu\nZakres:\nZakres (1,0 – 5,0) m/s\nEmisja CH4 i CO2 (z obliczeń)\nMetoda termoanemometryczna","reference":"PL-PB-26 wydanie 04 z dnia 24.11.2020 r.","norm_bases":["PL-PB-26 wydanie 04 z dnia 24.11.2020 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy składowiskowe Prędkość przepływu gazu\nZakres:\nZakres (1,0 – 5,0) m/s\nEmisja CH4 i CO2 (z obliczeń)\nMetoda termoanemometryczna PL-PB-26 wydanie 04 z dnia 24.11.2020 r. Gazy skladowiskowe Predkosc przeplywu gazu\nZakres:\nZakres (1,0 – 5,0) m/s\nEmisja CH4 i CO2 (z obliczen)\nMetoda termoanemometryczna PL-PB-26 wydanie 04 z dnia 24.11.2020 r.","categories":["environment"],"row_index":77,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Landfill gases Gas flow velocity Thermoanemometric method Range CH4 and CO2 emission (calculated) PL-PB-26 wydanie 04 z dnia 24.11.2020 r.","parameters_zh":[{"name":"范围","range":"(1,0 – 5,0) m/s"},{"name":"Emisja CH4 i CO2 (z obliczeń)"}],"search_zh":"填埋场气体 热线风速仪法 范围 PL-PB-26 wydanie 04 z dnia 24.11.2020 r.","test_object_zh":"填埋场气体","technique_zh":"热线风速仪法"},{"_id":"6a5dc9bbf1c10c8ce825df2f","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Odpady: kod 19 05 03, 19 05 99, 19 08 01, 19 08 02, 19 08 05, 19 12 12, 20 03 03, 20 03 06","test_object_en":"Waste: code 19 05 03, 19 05 99, 19 08 01, 19 08 02, 19 08 05, 19 12 12, 20 03 03, 20 03 06","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PL-IO-23 wydanie 05 z dnia 20.10.2022 r.","norm_bases":["PL-IO-23 wydanie 05 z dnia 20.10.2022 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady: kod 19 05 03, 19 05 99, 19 08 01, 19 08 02, 19 08 05, 19 12 12, 20 03 03, 20 03 06 Pobieranie próbek do badań chemicznych i fizycznych PL-IO-23 wydanie 05 z dnia 20.10.2022 r. Odpady: kod 19 05 03, 19 05 99, 19 08 01, 19 08 02, 19 08 05, 19 12 12, 20 03 03, 20 03 06 Pobieranie probek do badan chemicznych i fizycznych PL-IO-23 wydanie 05 z dnia 20.10.2022 r.","categories":["environment"],"row_index":78,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste: code 19 05 03, 19 05 99, 19 08 01, 19 08 02, 19 08 05, 19 12 12, 20 03 03, 20 03 06 Sampling for chemical and physical testing PL-IO-23 wydanie 05 z dnia 20.10.2022 r.","methodology_zh":"化学与物理检测用样品采集","search_zh":"化学与物理检测用样品采集 PL-IO-23 wydanie 05 z dnia 20.10.2022 r."},{"_id":"6a5dc9bbf1c10c8ce825df30","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Odpady: kod 19 05 99, 19 12 12","test_object_en":"Waste: code 19 05 99, 19 12 12","methodology":"Zapotrzebowanie tlenu (AT4)","methodology_en":"Oxygen demand (AT4)","parameters":[{"name":"Zakres","range":"(0,60 − 40,0) mg O2/g"}],"parameters_en":[{"name":"Range","range":"(0,60 − 40,0) mg O2/g"}],"technique":"Metoda manometryczna","techniques":["Metoda manometryczna"],"technique_en":"Manometric method","computed":[],"computed_en":[],"activity":"Zapotrzebowanie tlenu (AT4)\nZakres (0,60 − 40,0) mg O2/g\nMetoda manometryczna","reference":"PL-PB-13 wydanie 03 z dnia 10.09.2021 r.","norm_bases":["PL-PB-13 wydanie 03 z dnia 10.09.2021 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady: kod 19 05 99, 19 12 12 Zapotrzebowanie tlenu (AT4)\nZakres (0,60 − 40,0) mg O2/g\nMetoda manometryczna PL-PB-13 wydanie 03 z dnia 10.09.2021 r. Odpady: kod 19 05 99, 19 12 12 Zapotrzebowanie tlenu (AT4)\nZakres (0,60 − 40,0) mg O2/g\nMetoda manometryczna PL-PB-13 wydanie 03 z dnia 10.09.2021 r.","categories":["environment","metrology"],"row_index":79,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste: code 19 05 99, 19 12 12 Oxygen demand (AT4) Manometric method Range PL-PB-13 wydanie 03 z dnia 10.09.2021 r.","parameters_zh":[{"name":"范围","range":"(0,60 − 40,0) mg O2/g"}],"search_zh":"压力计法 范围 PL-PB-13 wydanie 03 z dnia 10.09.2021 r.","technique_zh":"压力计法"},{"_id":"6a5dc9bbf1c10c8ce825df31","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Odpady: kod 19 05 03, 19 05 99, 19 12 12,","test_object_en":"Waste: code 19 05 03, 19 05 99, 19 12 12,","methodology":"Sucha pozostałość (sucha masa)","methodology_en":"Dry residue (dry matter)","parameters":[{"name":"Zakres","range":"(40,0 − 98,0) %"}],"parameters_en":[{"name":"Range","range":"(40,0 − 98,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Sucha pozostałość (sucha masa)\nZakres (40,0 − 98,0) %\nMetoda wagowa","reference":"PN-EN 15934:2013-02 z wyłączeniem metody B","norm_bases":["PN-EN 15934:2013-02 z wyłączeniem metody B"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady: kod 19 05 03, 19 05 99, 19 12 12, Sucha pozostałość (sucha masa)\nZakres (40,0 − 98,0) %\nMetoda wagowa PN-EN 15934:2013-02 z wyłączeniem metody B Odpady: kod 19 05 03, 19 05 99, 19 12 12, Sucha pozostalosc (sucha masa)\nZakres (40,0 − 98,0) %\nMetoda wagowa PN-EN 15934:2013-02 z wylaczeniem metody B","categories":["environment"],"row_index":80,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste: code 19 05 03, 19 05 99, 19 12 12, Dry residue (dry matter) Gravimetric method Range PN-EN 15934:2013-02 z wyłączeniem metody B","parameters_zh":[{"name":"范围","range":"(40,0 − 98,0) %"}],"search_zh":"废物：代码 19 05 03、19 05 99、19 12 12， 干残渣（干物质） 重量法 范围 PN-EN 15934:2013-02 z wyłączeniem metody B","technique_zh":"重量法","methodology_zh":"干残渣（干物质）","test_object_zh":"废物：代码 19 05 03、19 05 99、19 12 12，"},{"_id":"6a5dc9bbf1c10c8ce825df32","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Odpady: kod 19 05 03, 19 05 99, 19 12 12,","test_object_en":"Waste: code 19 05 03, 19 05 99, 19 12 12,","methodology":"Zawartość wody (z obliczeń)","methodology_en":"Water content (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wody (z obliczeń)","reference":"PN-EN 15934:2013-02 z wyłączeniem metody B","norm_bases":["PN-EN 15934:2013-02 z wyłączeniem metody B"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady: kod 19 05 03, 19 05 99, 19 12 12, Zawartość wody (z obliczeń) PN-EN 15934:2013-02 z wyłączeniem metody B Odpady: kod 19 05 03, 19 05 99, 19 12 12, Zawartosc wody (z obliczen) PN-EN 15934:2013-02 z wylaczeniem metody B","categories":["environment","water"],"row_index":81,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste: code 19 05 03, 19 05 99, 19 12 12, Water content (calculated) PN-EN 15934:2013-02 z wyłączeniem metody B","methodology_zh":"水分含量（计算值）","search_zh":"废物：代码 19 05 03、19 05 99、19 12 12， 水分含量（计算值） PN-EN 15934:2013-02 z wyłączeniem metody B","test_object_zh":"废物：代码 19 05 03、19 05 99、19 12 12，"},{"_id":"6a5dc9bbf1c10c8ce825df33","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Odpady: kod 19 05 03, 19 05 99, 19 12 12,","test_object_en":"Waste: code 19 05 03, 19 05 99, 19 12 12,","methodology":"Strata przy prażeniu Substancje organiczne","methodology_en":"Loss on ignition Organic substances","parameters":[{"name":"Zakres","range":"(10,0 − 30,0) %"}],"parameters_en":[{"name":"Range","range":"(10,0 − 30,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Strata przy prażeniu Substancje organiczne\nZakres (10,0 − 30,0) %\nMetoda wagowa","reference":"PN-EN 15935:2022-01","norm_bases":["PN-EN 15935:2022-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady: kod 19 05 03, 19 05 99, 19 12 12, Strata przy prażeniu Substancje organiczne\nZakres (10,0 − 30,0) %\nMetoda wagowa PN-EN 15935:2022-01 Odpady: kod 19 05 03, 19 05 99, 19 12 12, Strata przy prazeniu Substancje organiczne\nZakres (10,0 − 30,0) %\nMetoda wagowa PN-EN 15935:2022-01","categories":["environment"],"row_index":82,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste: code 19 05 03, 19 05 99, 19 12 12, Loss on ignition Organic substances Gravimetric method Range PN-EN 15935:2022-01","parameters_zh":[{"name":"范围","range":"(10,0 − 30,0) %"}],"search_zh":"废物：代码 19 05 03、19 05 99、19 12 12， 重量法 范围 PN-EN 15935:2022-01","technique_zh":"重量法","test_object_zh":"废物：代码 19 05 03、19 05 99、19 12 12，"},{"_id":"6a5dc9bbf1c10c8ce825df34","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Odpady: kod 19 05 03, 19 05 99, 19 12 12,","test_object_en":"Waste: code 19 05 03, 19 05 99, 19 12 12,","methodology":"Pozostałość po prażeniu (substancje mineralne) (z obliczeń)","methodology_en":"Residue on ignition (mineral substances) (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pozostałość po prażeniu (substancje mineralne) (z obliczeń)","reference":"PN-EN 15935:2022-01","norm_bases":["PN-EN 15935:2022-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady: kod 19 05 03, 19 05 99, 19 12 12, Pozostałość po prażeniu (substancje mineralne) (z obliczeń) PN-EN 15935:2022-01 Odpady: kod 19 05 03, 19 05 99, 19 12 12, Pozostalosc po prazeniu (substancje mineralne) (z obliczen) PN-EN 15935:2022-01","categories":["environment"],"row_index":83,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste: code 19 05 03, 19 05 99, 19 12 12, Residue on ignition (mineral substances) (calculated) PN-EN 15935:2022-01","methodology_zh":"灼烧残渣（矿物质）（由计算得出）","search_zh":"废物：代码 19 05 03、19 05 99、19 12 12， 灼烧残渣（矿物质）（由计算得出） PN-EN 15935:2022-01","test_object_zh":"废物：代码 19 05 03、19 05 99、19 12 12，"},{"_id":"6a5dc9bbf1c10c8ce825df35","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Odpady: kod 19 08 01","test_object_en":"Waste: code 19 08 01","methodology":"Sucha pozostałość (sucha masa)","methodology_en":"Dry residue (dry matter)","parameters":[{"name":"Zakres","range":"(10,0 − 80,0) %"}],"parameters_en":[{"name":"Range","range":"(10,0 − 80,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Sucha pozostałość (sucha masa)\nZakres (10,0 − 80,0) %\nMetoda wagowa","reference":"PN-EN 15934:2013-02 z wyłączeniem metody B","norm_bases":["PN-EN 15934:2013-02 z wyłączeniem metody B"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady: kod 19 08 01 Sucha pozostałość (sucha masa)\nZakres (10,0 − 80,0) %\nMetoda wagowa PN-EN 15934:2013-02 z wyłączeniem metody B Odpady: kod 19 08 01 Sucha pozostalosc (sucha masa)\nZakres (10,0 − 80,0) %\nMetoda wagowa PN-EN 15934:2013-02 z wylaczeniem metody B","categories":["environment"],"row_index":84,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste: code 19 08 01 Dry residue (dry matter) Gravimetric method Range PN-EN 15934:2013-02 z wyłączeniem metody B","parameters_zh":[{"name":"范围","range":"(10,0 − 80,0) %"}],"search_zh":"废物：代码 19 08 01 干残渣（干物质） 重量法 范围 PN-EN 15934:2013-02 z wyłączeniem metody B","technique_zh":"重量法","methodology_zh":"干残渣（干物质）","test_object_zh":"废物：代码 19 08 01"},{"_id":"6a5dc9bbf1c10c8ce825df36","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Odpady: kod 19 08 01","test_object_en":"Waste: code 19 08 01","methodology":"Zawartość wody (z obliczeń)","methodology_en":"Water content (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wody (z obliczeń)","reference":"PN-EN 15934:2013-02 z wyłączeniem metody B","norm_bases":["PN-EN 15934:2013-02 z wyłączeniem metody B"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady: kod 19 08 01 Zawartość wody (z obliczeń) PN-EN 15934:2013-02 z wyłączeniem metody B Odpady: kod 19 08 01 Zawartosc wody (z obliczen) PN-EN 15934:2013-02 z wylaczeniem metody B","categories":["environment","water"],"row_index":85,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste: code 19 08 01 Water content (calculated) PN-EN 15934:2013-02 z wyłączeniem metody B","methodology_zh":"水分含量（计算值）","search_zh":"废物：代码 19 08 01 水分含量（计算值） PN-EN 15934:2013-02 z wyłączeniem metody B","test_object_zh":"废物：代码 19 08 01"},{"_id":"6a5dc9bbf1c10c8ce825df37","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Odpady: kod 19 08 01","test_object_en":"Waste: code 19 08 01","methodology":"Strata przy prażeniu Substancje organiczne","methodology_en":"Loss on ignition Organic substances","parameters":[{"name":"Zakres","range":"(70,0 − 98,0) %"}],"parameters_en":[{"name":"Range","range":"(70,0 − 98,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Strata przy prażeniu Substancje organiczne\nZakres (70,0 − 98,0) %\nMetoda wagowa","reference":"PN-EN 15935:2022-01","norm_bases":["PN-EN 15935:2022-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady: kod 19 08 01 Strata przy prażeniu Substancje organiczne\nZakres (70,0 − 98,0) %\nMetoda wagowa PN-EN 15935:2022-01 Odpady: kod 19 08 01 Strata przy prazeniu Substancje organiczne\nZakres (70,0 − 98,0) %\nMetoda wagowa PN-EN 15935:2022-01","categories":["environment"],"row_index":86,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste: code 19 08 01 Loss on ignition Organic substances Gravimetric method Range PN-EN 15935:2022-01","parameters_zh":[{"name":"范围","range":"(70,0 − 98,0) %"}],"search_zh":"废物：代码 19 08 01 重量法 范围 PN-EN 15935:2022-01","technique_zh":"重量法","test_object_zh":"废物：代码 19 08 01"},{"_id":"6a5dc9bbf1c10c8ce825df38","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Odpady: kod 19 08 01","test_object_en":"Waste: code 19 08 01","methodology":"Pozostałość po prażeniu (substancje mineralne) (z obliczeń)","methodology_en":"Residue on ignition (mineral substances) (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pozostałość po prażeniu (substancje mineralne) (z obliczeń)","reference":"PN-EN 15935:2022-01","norm_bases":["PN-EN 15935:2022-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady: kod 19 08 01 Pozostałość po prażeniu (substancje mineralne) (z obliczeń) PN-EN 15935:2022-01 Odpady: kod 19 08 01 Pozostalosc po prazeniu (substancje mineralne) (z obliczen) PN-EN 15935:2022-01","categories":["environment"],"row_index":87,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste: code 19 08 01 Residue on ignition (mineral substances) (calculated) PN-EN 15935:2022-01","methodology_zh":"灼烧残渣（矿物质）（由计算得出）","search_zh":"废物：代码 19 08 01 灼烧残渣（矿物质）（由计算得出） PN-EN 15935:2022-01","test_object_zh":"废物：代码 19 08 01"},{"_id":"6a5dc9bbf1c10c8ce825df39","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Odpady: kod 19 08 02","test_object_en":"Waste: code 19 08 02","methodology":"Sucha pozostałość (sucha masa)","methodology_en":"Dry residue (dry matter)","parameters":[{"name":"Zakres","range":"(75,0 − 99,5) %"}],"parameters_en":[{"name":"Range","range":"(75,0 − 99,5) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Sucha pozostałość (sucha masa)\nZakres (75,0 − 99,5) %\nMetoda wagowa","reference":"PN-EN 15934:2013-02 z wyłączeniem metody B","norm_bases":["PN-EN 15934:2013-02 z wyłączeniem metody B"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady: kod 19 08 02 Sucha pozostałość (sucha masa)\nZakres (75,0 − 99,5) %\nMetoda wagowa PN-EN 15934:2013-02 z wyłączeniem metody B Odpady: kod 19 08 02 Sucha pozostalosc (sucha masa)\nZakres (75,0 − 99,5) %\nMetoda wagowa PN-EN 15934:2013-02 z wylaczeniem metody B","categories":["environment"],"row_index":88,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste: code 19 08 02 Dry residue (dry matter) Gravimetric method Range PN-EN 15934:2013-02 z wyłączeniem metody B","parameters_zh":[{"name":"范围","range":"(75,0 − 99,5) %"}],"search_zh":"废物：代码 19 08 02 干残渣（干物质） 重量法 范围 PN-EN 15934:2013-02 z wyłączeniem metody B","technique_zh":"重量法","methodology_zh":"干残渣（干物质）","test_object_zh":"废物：代码 19 08 02"},{"_id":"6a5dc9bbf1c10c8ce825df3a","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Odpady: kod 19 08 02","test_object_en":"Waste: code 19 08 02","methodology":"Zawartość wody (z obliczeń)","methodology_en":"Water content (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wody (z obliczeń)","reference":"PN-EN 15934:2013-02 z wyłączeniem metody B","norm_bases":["PN-EN 15934:2013-02 z wyłączeniem metody B"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady: kod 19 08 02 Zawartość wody (z obliczeń) PN-EN 15934:2013-02 z wyłączeniem metody B Odpady: kod 19 08 02 Zawartosc wody (z obliczen) PN-EN 15934:2013-02 z wylaczeniem metody B","categories":["environment","water"],"row_index":89,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste: code 19 08 02 Water content (calculated) PN-EN 15934:2013-02 z wyłączeniem metody B","methodology_zh":"水分含量（计算值）","search_zh":"废物：代码 19 08 02 水分含量（计算值） PN-EN 15934:2013-02 z wyłączeniem metody B","test_object_zh":"废物：代码 19 08 02"},{"_id":"6a5dc9bbf1c10c8ce825df3b","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Odpady: kod 19 08 02","test_object_en":"Waste: code 19 08 02","methodology":"Strata przy prażeniu Substancje organiczne","methodology_en":"Loss on ignition Organic substances","parameters":[{"name":"Zakres","range":"(1,50 − 20,0) %"}],"parameters_en":[{"name":"Range","range":"(1,50 − 20,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Strata przy prażeniu Substancje organiczne\nZakres (1,50 − 20,0) %\nMetoda wagowa","reference":"PN-EN 15935:2022-01","norm_bases":["PN-EN 15935:2022-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady: kod 19 08 02 Strata przy prażeniu Substancje organiczne\nZakres (1,50 − 20,0) %\nMetoda wagowa PN-EN 15935:2022-01 Odpady: kod 19 08 02 Strata przy prazeniu Substancje organiczne\nZakres (1,50 − 20,0) %\nMetoda wagowa PN-EN 15935:2022-01","categories":["environment"],"row_index":90,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste: code 19 08 02 Loss on ignition Organic substances Gravimetric method Range PN-EN 15935:2022-01","parameters_zh":[{"name":"范围","range":"(1,50 − 20,0) %"}],"search_zh":"废物：代码 19 08 02 重量法 范围 PN-EN 15935:2022-01","technique_zh":"重量法","test_object_zh":"废物：代码 19 08 02"},{"_id":"6a5dc9bbf1c10c8ce825df3c","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Odpady: kod 19 08 02","test_object_en":"Waste: code 19 08 02","methodology":"Pozostałość po prażeniu (substancje mineralne) (z obliczeń)","methodology_en":"Residue on ignition (mineral substances) (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pozostałość po prażeniu (substancje mineralne) (z obliczeń)","reference":"PN-EN 15935:2022-01","norm_bases":["PN-EN 15935:2022-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady: kod 19 08 02 Pozostałość po prażeniu (substancje mineralne) (z obliczeń) PN-EN 15935:2022-01 Odpady: kod 19 08 02 Pozostalosc po prazeniu (substancje mineralne) (z obliczen) PN-EN 15935:2022-01","categories":["environment"],"row_index":91,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste: code 19 08 02 Residue on ignition (mineral substances) (calculated) PN-EN 15935:2022-01","methodology_zh":"灼烧残渣（矿物质）（由计算得出）","search_zh":"废物：代码 19 08 02 灼烧残渣（矿物质）（由计算得出） PN-EN 15935:2022-01","test_object_zh":"废物：代码 19 08 02"},{"_id":"6a5dc9bbf1c10c8ce825df3d","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Zawartość metali","methodology_en":"Metal content","parameters":[{"name":"Pb","range":"(2,5 –100) mg/kg"},{"name":"Cu","range":"(2,5 –100) mg/kg"},{"name":"Cd","range":"(0,10 – 100) mg/kg"},{"name":"Zn","range":"(2,5 – 500) mg/kg"},{"name":"Cr","range":"(2,5 – 200) mg/kg"},{"name":"Ni","range":"(2,5 – 100) mg/kg"}],"parameters_en":[{"name":"Pb","range":"(2,5 –100) mg/kg"},{"name":"Cu","range":"(2,5 –100) mg/kg"},{"name":"Cd","range":"(0,10 – 100) mg/kg"},{"name":"Zn","range":"(2,5 – 500) mg/kg"},{"name":"Cr","range":"(2,5 – 200) mg/kg"},{"name":"Ni","range":"(2,5 – 100) mg/kg"}],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","computed":[],"computed_en":[],"activity":"Zawartość metali\nZakres:\nPb (2,5 –100) mg/kg\nCu (2,5 –100) mg/kg\nCd (0,10 – 100) mg/kg\nZn (2,5 – 500) mg/kg\nCr (2,5 – 200) mg/kg\nNi (2,5 – 100) mg/kg\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"PN-EN 16171:2017-02","norm_bases":["PN-EN 16171:2017-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Zawartość metali\nZakres:\nPb (2,5 –100) mg/kg\nCu (2,5 –100) mg/kg\nCd (0,10 – 100) mg/kg\nZn (2,5 – 500) mg/kg\nCr (2,5 – 200) mg/kg\nNi (2,5 – 100) mg/kg\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) PN-EN 16171:2017-02 Gleba Zawartosc metali\nZakres:\nPb (2,5 –100) mg/kg\nCu (2,5 –100) mg/kg\nCd (0,10 – 100) mg/kg\nZn (2,5 – 500) mg/kg\nCr (2,5 – 200) mg/kg\nNi (2,5 – 100) mg/kg\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) PN-EN 16171:2017-02","categories":["materials","environment"],"row_index":92,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Soil Metal content Inductively coupled plasma mass spectrometry (ICP-MS) Pb Cu Cd Zn Cr Ni PN-EN 16171:2017-02","parameters_zh":[{"name":"Pb","range":"(2,5 –100) mg/kg"},{"name":"Cu","range":"(2,5 –100) mg/kg"},{"name":"Cd","range":"(0,10 – 100) mg/kg"},{"name":"Zn","range":"(2,5 – 500) mg/kg"},{"name":"Cr","range":"(2,5 – 200) mg/kg"},{"name":"Ni","range":"(2,5 – 100) mg/kg"}],"search_zh":"土壤 金属含量 电感耦合等离子体质谱法（ICP-MS） Pb Cu Cd Zn Cr Ni PN-EN 16171:2017-02","technique_zh":"电感耦合等离子体质谱法（ICP-MS）","test_object_zh":"土壤","methodology_zh":"金属含量"},{"_id":"6a5dc9bbf1c10c8ce825df3e","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Zawartość ogólnego węgla organicznego (TOC)","methodology_en":"Total organic carbon (TOC) content","parameters":[{"name":"Zakres","range":"(0,50 – 7,9) %"}],"parameters_en":[{"name":"Range","range":"(0,50 – 7,9) %"}],"technique":"Metoda spektrometrii w zakresie podczerwieni IR","techniques":["Metoda spektrometrii w zakresie podczerwieni IR"],"technique_en":"Spectrometry method in the infrared range IR","computed":[],"computed_en":[],"activity":"Zawartość ogólnego węgla organicznego (TOC)\nZakres (0,50 – 7,9) %\nMetoda spektrometrii w zakresie podczerwieni IR","reference":"PN-EN 15936:2022-07 z wyłączeniem Metody A","norm_bases":["PN-EN 15936:2022-07 z wyłączeniem Metody A"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Zawartość ogólnego węgla organicznego (TOC)\nZakres (0,50 – 7,9) %\nMetoda spektrometrii w zakresie podczerwieni IR PN-EN 15936:2022-07 z wyłączeniem Metody A Gleba Zawartosc ogolnego wegla organicznego (TOC)\nZakres (0,50 – 7,9) %\nMetoda spektrometrii w zakresie podczerwieni IR PN-EN 15936:2022-07 z wylaczeniem Metody A","categories":["environment"],"row_index":93,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Soil Total organic carbon (TOC) content Spectrometry method in the infrared range IR Range PN-EN 15936:2022-07 z wyłączeniem Metody A","parameters_zh":[{"name":"范围","range":"(0,50 – 7,9) %"}],"search_zh":"土壤 总有机碳（TOC）含量 红外光谱法 IR 范围 PN-EN 15936:2022-07 z wyłączeniem Metody A","test_object_zh":"土壤","technique_zh":"红外光谱法 IR","methodology_zh":"总有机碳（TOC）含量"},{"_id":"6a5dc9bbf1c10c8ce825df3f","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Zawartość rtęci","methodology_en":"Mercury content","parameters":[{"name":"Zakres","range":"(0,013 – 3,3) mg/kg"}],"parameters_en":[{"name":"Range","range":"(0,013 – 3,3) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)"],"technique_en":"Cold vapour atomic absorption spectrometry (CVAAS)","computed":[],"computed_en":[],"activity":"Zawartość rtęci\nZakres (0,013 – 3,3) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"PN-EN 16175-1:2017-02","norm_bases":["PN-EN 16175-1:2017-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Zawartość rtęci\nZakres (0,013 – 3,3) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN 16175-1:2017-02 Gleba Zawartosc rteci\nZakres (0,013 – 3,3) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN 16175-1:2017-02","categories":["environment"],"row_index":94,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Soil Mercury content Cold vapour atomic absorption spectrometry (CVAAS) Range PN-EN 16175-1:2017-02","methodology_zh":"汞含量","parameters_zh":[{"name":"范围","range":"(0,013 – 3,3) mg/kg"}],"search_zh":"土壤 汞含量 冷蒸气原子吸收光谱法（CVAAS） 范围 PN-EN 16175-1:2017-02","technique_zh":"冷蒸气原子吸收光谱法（CVAAS）","test_object_zh":"土壤"},{"_id":"6a5dc9bbf1c10c8ce825df40","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Gleba mineralna","test_object_en":"Mineral soil","methodology":"Zawartość magnezu przyswajalnego","methodology_en":"Available magnesium content","parameters":[{"name":"Zakres","range":"(6,0 – 30) mg Mg/100 g"}],"parameters_en":[{"name":"Range","range":"(6,0 – 30) mg Mg/100 g"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"technique_en":"Flame atomic absorption spectrometry (FAAS)","computed":[],"computed_en":[],"activity":"Zawartość magnezu przyswajalnego\nZakres (6,0 – 30) mg Mg/100 g\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-R-04020:1994 +Az1:2004","norm_bases":["PN-R-04020:1994 +Az1:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba mineralna Zawartość magnezu przyswajalnego\nZakres (6,0 – 30) mg Mg/100 g\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-R-04020:1994 +Az1:2004 Gleba mineralna Zawartosc magnezu przyswajalnego\nZakres (6,0 – 30) mg Mg/100 g\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-R-04020:1994 +Az1:2004","categories":["environment"],"row_index":95,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Mineral soil Available magnesium content Flame atomic absorption spectrometry (FAAS) Range PN-R-04020:1994 +Az1:2004","parameters_zh":[{"name":"范围","range":"(6,0 – 30) mg Mg/100 g"}],"search_zh":"矿质土壤 有效镁含量 火焰原子吸收光谱法（FAAS） 范围 PN-R-04020:1994 +Az1:2004","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"矿质土壤","methodology_zh":"有效镁含量"},{"_id":"6a5dc9bbf1c10c8ce825df41","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Gleba mineralna","test_object_en":"Mineral soil","methodology":"Zawartość potasu przyswajalnego","methodology_en":"Available potassium content","parameters":[{"name":"Zakres","range":"(7,0 – 60) mg K2O/100 g"}],"parameters_en":[{"name":"Range","range":"(7,0 – 60) mg K2O/100 g"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"technique_en":"Flame atomic absorption spectrometry (FAAS)","computed":[],"computed_en":[],"activity":"Zawartość potasu przyswajalnego\nZakres (7,0 – 60) mg K2O/100 g\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-R-04022:1996 +Az1:2002","norm_bases":["PN-R-04022:1996 +Az1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba mineralna Zawartość potasu przyswajalnego\nZakres (7,0 – 60) mg K2O/100 g\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-R-04022:1996 +Az1:2002 Gleba mineralna Zawartosc potasu przyswajalnego\nZakres (7,0 – 60) mg K2O/100 g\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-R-04022:1996 +Az1:2002","categories":["environment"],"row_index":96,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Mineral soil Available potassium content Flame atomic absorption spectrometry (FAAS) Range PN-R-04022:1996 +Az1:2002","parameters_zh":[{"name":"范围","range":"(7,0 – 60) mg K2O/100 g"}],"search_zh":"矿质土壤 速效钾含量 火焰原子吸收光谱法（FAAS） 范围 PN-R-04022:1996 +Az1:2002","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"矿质土壤","methodology_zh":"速效钾含量"},{"_id":"6a5dc9bbf1c10c8ce825df42","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby","test_object_en":"plant growth aids: - soil improvers","methodology":"Zawartość metali","methodology_en":"Metal content","parameters":[{"name":"Pb","range":"(2,5 – 200) mg/kg"},{"name":"Cd","range":"(0,10 – 100) mg/kg"},{"name":"Cr","range":"(2,5 – 200) mg/kg"},{"name":"Ni","range":"(2,5 – 100) mg/kg"}],"parameters_en":[{"name":"Pb","range":"(2,5 – 200) mg/kg"},{"name":"Cd","range":"(0,10 – 100) mg/kg"},{"name":"Cr","range":"(2,5 – 200) mg/kg"},{"name":"Ni","range":"(2,5 – 100) mg/kg"}],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","computed":[],"computed_en":[],"activity":"Zawartość metali\nZakres:\nPb (2,5 – 200) mg/kg\nCd (0,10 – 100) mg/kg\nCr (2,5 – 200) mg/kg\nNi (2,5 – 100) mg/kg\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"PN-EN 16171:2017-02","norm_bases":["PN-EN 16171:2017-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby Zawartość metali\nZakres:\nPb (2,5 – 200) mg/kg\nCd (0,10 – 100) mg/kg\nCr (2,5 – 200) mg/kg\nNi (2,5 – 100) mg/kg\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) PN-EN 16171:2017-02 srodki wspomagajace uprawe roslin: - srodki poprawiajace wlasciwosci gleby Zawartosc metali\nZakres:\nPb (2,5 – 200) mg/kg\nCd (0,10 – 100) mg/kg\nCr (2,5 – 200) mg/kg\nNi (2,5 – 100) mg/kg\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) PN-EN 16171:2017-02","categories":["materials"],"row_index":97,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"plant growth aids: - soil improvers Metal content Inductively coupled plasma mass spectrometry (ICP-MS) Pb Cd Cr Ni PN-EN 16171:2017-02","parameters_zh":[{"name":"Pb","range":"(2,5 – 200) mg/kg"},{"name":"Cd","range":"(0,10 – 100) mg/kg"},{"name":"Cr","range":"(2,5 – 200) mg/kg"},{"name":"Ni","range":"(2,5 – 100) mg/kg"}],"search_zh":"金属含量 电感耦合等离子体质谱法（ICP-MS） Pb Cd Cr Ni PN-EN 16171:2017-02","technique_zh":"电感耦合等离子体质谱法（ICP-MS）","methodology_zh":"金属含量"},{"_id":"6a5dc9bbf1c10c8ce825df43","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby","test_object_en":"plant growth aids: - soil improvers","methodology":"Zawartość rtęci","methodology_en":"Mercury content","parameters":[{"name":"Zakres","range":"(0,013 – 33) mg/kg"}],"parameters_en":[{"name":"Range","range":"(0,013 – 33) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)"],"technique_en":"Cold vapour atomic absorption spectrometry (CVAAS)","computed":[],"computed_en":[],"activity":"Zawartość rtęci\nZakres (0,013 – 33) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"PN-EN 16175-1:2017-02","norm_bases":["PN-EN 16175-1:2017-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby Zawartość rtęci\nZakres (0,013 – 33) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN 16175-1:2017-02 srodki wspomagajace uprawe roslin: - srodki poprawiajace wlasciwosci gleby Zawartosc rteci\nZakres (0,013 – 33) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN 16175-1:2017-02","categories":["other"],"row_index":98,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"plant growth aids: - soil improvers Mercury content Cold vapour atomic absorption spectrometry (CVAAS) Range PN-EN 16175-1:2017-02","methodology_zh":"汞含量","parameters_zh":[{"name":"范围","range":"(0,013 – 33) mg/kg"}],"search_zh":"汞含量 冷蒸气原子吸收光谱法（CVAAS） 范围 PN-EN 16175-1:2017-02","technique_zh":"冷蒸气原子吸收光谱法（CVAAS）"},{"_id":"6a5dc9bbf1c10c8ce825df44","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby","test_object_en":"plant growth aids: - soil improvers","methodology":"Zawartość potasu","methodology_en":"Potassium content","parameters":[{"name":"Zakres","range":"(0,13 – 1,32) % m/m"}],"parameters_en":[{"name":"Range","range":"(0,13 – 1,32) % m/m"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"technique_en":"Flame atomic absorption spectrometry (FAAS)","computed":[],"computed_en":[],"activity":"Zawartość potasu\nZakres (0,13 – 1,32) % m/m\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PL-PB-28 wydanie 04 z dnia 20.08.2019 r.","norm_bases":["PL-PB-28 wydanie 04 z dnia 20.08.2019 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby Zawartość potasu\nZakres (0,13 – 1,32) % m/m\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PL-PB-28 wydanie 04 z dnia 20.08.2019 r. srodki wspomagajace uprawe roslin: - srodki poprawiajace wlasciwosci gleby Zawartosc potasu\nZakres (0,13 – 1,32) % m/m\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PL-PB-28 wydanie 04 z dnia 20.08.2019 r.","categories":["other"],"row_index":99,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"plant growth aids: - soil improvers Potassium content Flame atomic absorption spectrometry (FAAS) Range PL-PB-28 wydanie 04 z dnia 20.08.2019 r.","parameters_zh":[{"name":"范围","range":"(0,13 – 1,32) % m/m"}],"search_zh":"钾含量 火焰原子吸收光谱法（FAAS） 范围 PL-PB-28 wydanie 04 z dnia 20.08.2019 r.","technique_zh":"火焰原子吸收光谱法（FAAS）","methodology_zh":"钾含量"},{"_id":"6a5dc9bbf1c10c8ce825df45","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Zawartość metali","methodology_en":"Metal content","parameters":[{"name":"Pb","range":"(2,5 –5000) mg/kg"},{"name":"Cu","range":"(2,5 –5000) mg/kg"},{"name":"Cd","range":"(0,10 – 100) mg/kg"},{"name":"Zn","range":"(2,5 – 10000) mg/kg"},{"name":"Cr","range":"(2,5 – 5000) mg/kg"},{"name":"Ni","range":"(2,5 – 5000) mg/kg"}],"parameters_en":[{"name":"Pb","range":"(2,5 –5000) mg/kg"},{"name":"Cu","range":"(2,5 –5000) mg/kg"},{"name":"Cd","range":"(0,10 – 100) mg/kg"},{"name":"Zn","range":"(2,5 – 10000) mg/kg"},{"name":"Cr","range":"(2,5 – 5000) mg/kg"},{"name":"Ni","range":"(2,5 – 5000) mg/kg"}],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","computed":[],"computed_en":[],"activity":"Zawartość metali\nZakres:\nPb (2,5 –5000) mg/kg\nCu (2,5 –5000) mg/kg\nCd (0,10 – 100) mg/kg\nZn (2,5 – 10000) mg/kg\nCr (2,5 – 5000) mg/kg\nNi (2,5 – 5000) mg/kg\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"PN-EN 16171:2017-02","norm_bases":["PN-EN 16171:2017-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Zawartość metali\nZakres:\nPb (2,5 –5000) mg/kg\nCu (2,5 –5000) mg/kg\nCd (0,10 – 100) mg/kg\nZn (2,5 – 10000) mg/kg\nCr (2,5 – 5000) mg/kg\nNi (2,5 – 5000) mg/kg\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) PN-EN 16171:2017-02 Osady sciekowe Zawartosc metali\nZakres:\nPb (2,5 –5000) mg/kg\nCu (2,5 –5000) mg/kg\nCd (0,10 – 100) mg/kg\nZn (2,5 – 10000) mg/kg\nCr (2,5 – 5000) mg/kg\nNi (2,5 – 5000) mg/kg\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) PN-EN 16171:2017-02","categories":["water","materials"],"row_index":100,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge Metal content Inductively coupled plasma mass spectrometry (ICP-MS) Pb Cu Cd Zn Cr Ni PN-EN 16171:2017-02","parameters_zh":[{"name":"Pb","range":"(2,5 –5000) mg/kg"},{"name":"Cu","range":"(2,5 –5000) mg/kg"},{"name":"Cd","range":"(0,10 – 100) mg/kg"},{"name":"Zn","range":"(2,5 – 10000) mg/kg"},{"name":"Cr","range":"(2,5 – 5000) mg/kg"},{"name":"Ni","range":"(2,5 – 5000) mg/kg"}],"search_zh":"污泥 金属含量 电感耦合等离子体质谱法（ICP-MS） Pb Cu Cd Zn Cr Ni PN-EN 16171:2017-02","technique_zh":"电感耦合等离子体质谱法（ICP-MS）","test_object_zh":"污泥","methodology_zh":"金属含量"},{"_id":"6a5dc9bbf1c10c8ce825df46","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Zawartość rtęci","methodology_en":"Mercury content","parameters":[{"name":"Zakres","range":"(0,013 – 33) mg/kg"}],"parameters_en":[{"name":"Range","range":"(0,013 – 33) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)"],"technique_en":"Cold vapour atomic absorption spectrometry (CVAAS)","computed":[],"computed_en":[],"activity":"Zawartość rtęci\nZakres (0,013 – 33) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"PN-EN 16175-1:2017-02","norm_bases":["PN-EN 16175-1:2017-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Zawartość rtęci\nZakres (0,013 – 33) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN 16175-1:2017-02 Osady sciekowe Zawartosc rteci\nZakres (0,013 – 33) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN 16175-1:2017-02","categories":["water"],"row_index":101,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge Mercury content Cold vapour atomic absorption spectrometry (CVAAS) Range PN-EN 16175-1:2017-02","methodology_zh":"汞含量","parameters_zh":[{"name":"范围","range":"(0,013 – 33) mg/kg"}],"search_zh":"污泥 汞含量 冷蒸气原子吸收光谱法（CVAAS） 范围 PN-EN 16175-1:2017-02","technique_zh":"冷蒸气原子吸收光谱法（CVAAS）","test_object_zh":"污泥"},{"_id":"6a5dc9bbf1c10c8ce825df47","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Zawartość wapnia","methodology_en":"Calcium content","parameters":[{"name":"Zakres","range":"(0,40 – 30)%"},{"name":"Zawartość magnezu"},{"name":"Zakres","range":"(0,10 – 1,00)%"}],"parameters_en":[{"name":"Range","range":"(0,40 – 30)%"},{"name":"Magnesium content"},{"name":"Range","range":"(0,10 – 1,00)%"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"technique_en":"Flame atomic absorption spectrometry (FAAS)","computed":[],"computed_en":[],"activity":"Zawartość wapnia\nZakres:\nZakres (0,40 – 30)%\nZawartość magnezu\nZakres (0,10 – 1,00)%\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-EN ISO 7980:2002 | PN-EN 16173:2012","norm_bases":["PN-EN ISO 7980:2002","PN-EN 16173:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Zawartość wapnia\nZakres:\nZakres (0,40 – 30)%\nZawartość magnezu\nZakres (0,10 – 1,00)%\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN ISO 7980:2002 | PN-EN 16173:2012 Osady sciekowe Zawartosc wapnia\nZakres:\nZakres (0,40 – 30)%\nZawartosc magnezu\nZakres (0,10 – 1,00)%\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN ISO 7980:2002 | PN-EN 16173:2012","categories":["water"],"row_index":102,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge Calcium content Flame atomic absorption spectrometry (FAAS) Range Magnesium content Range PN-EN ISO 7980:2002 | PN-EN 16173:2012","parameters_zh":[{"name":"范围","range":"(0,40 – 30)%"},{"name":"镁含量"},{"name":"范围","range":"(0,10 – 1,00)%"}],"search_zh":"污泥 钙含量 火焰原子吸收光谱法（FAAS） 范围 镁含量 范围 PN-EN ISO 7980:2002 | PN-EN 16173:2012","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"污泥","methodology_zh":"钙含量"},{"_id":"6a5dc9bbf1c10c8ce825df48","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Odpady: kod 19 05 99","test_object_en":"Waste: code 19 05 99","methodology":"Zawartość ogólnego węgla organicznego (TOC)","methodology_en":"Total organic carbon (TOC) content","parameters":[{"name":"Zakres","range":"(3,2 – 20) %"}],"parameters_en":[{"name":"Range","range":"(3,2 – 20) %"}],"technique":"Metoda spektrometrii w zakresie podczerwieni IR","techniques":["Metoda spektrometrii w zakresie podczerwieni IR"],"technique_en":"Spectrometry method in the infrared range IR","computed":[],"computed_en":[],"activity":"Zawartość ogólnego węgla organicznego (TOC)\nZakres (3,2 – 20) %\nMetoda spektrometrii w zakresie podczerwieni IR","reference":"PN-EN 15936:2022-07 z wyłączeniem Metody A","norm_bases":["PN-EN 15936:2022-07 z wyłączeniem Metody A"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady: kod 19 05 99 Zawartość ogólnego węgla organicznego (TOC)\nZakres (3,2 – 20) %\nMetoda spektrometrii w zakresie podczerwieni IR PN-EN 15936:2022-07 z wyłączeniem Metody A Odpady: kod 19 05 99 Zawartosc ogolnego wegla organicznego (TOC)\nZakres (3,2 – 20) %\nMetoda spektrometrii w zakresie podczerwieni IR PN-EN 15936:2022-07 z wylaczeniem Metody A","categories":["environment"],"row_index":103,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste: code 19 05 99 Total organic carbon (TOC) content Spectrometry method in the infrared range IR Range PN-EN 15936:2022-07 z wyłączeniem Metody A","parameters_zh":[{"name":"范围","range":"(3,2 – 20) %"}],"search_zh":"总有机碳（TOC）含量 红外光谱法 IR 范围 PN-EN 15936:2022-07 z wyłączeniem Metody A","technique_zh":"红外光谱法 IR","methodology_zh":"总有机碳（TOC）含量"},{"_id":"6a5dc9bbf1c10c8ce825df49","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Odpady: kod 19 05 03, 19 05 99","test_object_en":"Waste: code 19 05 03, 19 05 99","methodology":"Zawartość rtęci","methodology_en":"Mercury content","parameters":[{"name":"Zakres","range":"(0,013 – 33) mg/kg"}],"parameters_en":[{"name":"Range","range":"(0,013 – 33) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)"],"technique_en":"Cold vapour atomic absorption spectrometry (CVAAS)","computed":[],"computed_en":[],"activity":"Zawartość rtęci\nZakres (0,013 – 33) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"PN-EN 16175-1:2017-02","norm_bases":["PN-EN 16175-1:2017-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady: kod 19 05 03, 19 05 99 Zawartość rtęci\nZakres (0,013 – 33) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN 16175-1:2017-02 Odpady: kod 19 05 03, 19 05 99 Zawartosc rteci\nZakres (0,013 – 33) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN 16175-1:2017-02","categories":["environment"],"row_index":104,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste: code 19 05 03, 19 05 99 Mercury content Cold vapour atomic absorption spectrometry (CVAAS) Range PN-EN 16175-1:2017-02","methodology_zh":"汞含量","parameters_zh":[{"name":"范围","range":"(0,013 – 33) mg/kg"}],"search_zh":"汞含量 冷蒸气原子吸收光谱法（CVAAS） 范围 PN-EN 16175-1:2017-02","technique_zh":"冷蒸气原子吸收光谱法（CVAAS）"},{"_id":"6a5dc9bbf1c10c8ce825df4a","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Odpady: kod 19 05 03, 19 05 99","test_object_en":"Waste: code 19 05 03, 19 05 99","methodology":"Zawartość metali","methodology_en":"Metal content","parameters":[{"name":"Pb","range":"(2,5 – 400) mg/kg"},{"name":"Cu","range":"(2,5 – 400) mg/kg"},{"name":"Cd","range":"(0,10 – 100) mg/kg"},{"name":"Zn","range":"(2,5 – 4000) mg/kg"},{"name":"Cr","range":"(2,5 – 400) mg/kg"},{"name":"Ni","range":"(2,5 – 400) mg/kg"}],"parameters_en":[{"name":"Pb","range":"(2,5 – 400) mg/kg"},{"name":"Cu","range":"(2,5 – 400) mg/kg"},{"name":"Cd","range":"(0,10 – 100) mg/kg"},{"name":"Zn","range":"(2,5 – 4000) mg/kg"},{"name":"Cr","range":"(2,5 – 400) mg/kg"},{"name":"Ni","range":"(2,5 – 400) mg/kg"}],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","computed":[],"computed_en":[],"activity":"Zawartość metali\nZakres:\nPb (2,5 – 400) mg/kg\nCu (2,5 – 400) mg/kg\nCd (0,10 – 100) mg/kg\nZn (2,5 – 4000) mg/kg\nCr (2,5 – 400) mg/kg\nNi (2,5 – 400) mg/kg\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"PN-EN 16171:2017-02","norm_bases":["PN-EN 16171:2017-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady: kod 19 05 03, 19 05 99 Zawartość metali\nZakres:\nPb (2,5 – 400) mg/kg\nCu (2,5 – 400) mg/kg\nCd (0,10 – 100) mg/kg\nZn (2,5 – 4000) mg/kg\nCr (2,5 – 400) mg/kg\nNi (2,5 – 400) mg/kg\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) PN-EN 16171:2017-02 Odpady: kod 19 05 03, 19 05 99 Zawartosc metali\nZakres:\nPb (2,5 – 400) mg/kg\nCu (2,5 – 400) mg/kg\nCd (0,10 – 100) mg/kg\nZn (2,5 – 4000) mg/kg\nCr (2,5 – 400) mg/kg\nNi (2,5 – 400) mg/kg\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) PN-EN 16171:2017-02","categories":["materials","environment"],"row_index":105,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste: code 19 05 03, 19 05 99 Metal content Inductively coupled plasma mass spectrometry (ICP-MS) Pb Cu Cd Zn Cr Ni PN-EN 16171:2017-02","parameters_zh":[{"name":"Pb","range":"(2,5 – 400) mg/kg"},{"name":"Cu","range":"(2,5 – 400) mg/kg"},{"name":"Cd","range":"(0,10 – 100) mg/kg"},{"name":"Zn","range":"(2,5 – 4000) mg/kg"},{"name":"Cr","range":"(2,5 – 400) mg/kg"},{"name":"Ni","range":"(2,5 – 400) mg/kg"}],"search_zh":"金属含量 电感耦合等离子体质谱法（ICP-MS） Pb Cu Cd Zn Cr Ni PN-EN 16171:2017-02","technique_zh":"电感耦合等离子体质谱法（ICP-MS）","methodology_zh":"金属含量"},{"_id":"6a5dc9bbf1c10c8ce825df4b","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie rtęci","methodology_en":"Mercury concentration","parameters":[{"name":"Zakres","range":"(0,50 – 10) μg/l"}],"parameters_en":[{"name":"Range","range":"(0,50 – 10) μg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem wodorków (HGAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem wodorków (HGAAS)"],"technique_en":"Hydride generation atomic absorption spectrometry (HGAAS)","computed":[],"computed_en":[],"activity":"Stężenie rtęci\nZakres (0,50 – 10) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem wodorków (HGAAS)","reference":"PN-EN ISO 12846:2012 z wyłączeniem p.6 + Ap1: 2016-07","norm_bases":["PN-EN ISO 12846:2012 z wyłączeniem p.6 + Ap1: 2016-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie rtęci\nZakres (0,50 – 10) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem wodorków (HGAAS) PN-EN ISO 12846:2012 z wyłączeniem p.6 + Ap1: 2016-07 Woda Stezenie rteci\nZakres (0,50 – 10) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem wodorkow (HGAAS) PN-EN ISO 12846:2012 z wylaczeniem p.6 + Ap1: 2016-07","categories":["water"],"row_index":106,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Mercury concentration Hydride generation atomic absorption spectrometry (HGAAS) Range PN-EN ISO 12846:2012 z wyłączeniem p.6 + Ap1: 2016-07","methodology_zh":"汞浓度","parameters_zh":[{"name":"范围","range":"(0,50 – 10) μg/l"}],"search_zh":"水 汞浓度 氢化物发生原子吸收光谱法（HGAAS） 范围 PN-EN ISO 12846:2012 z wyłączeniem p.6 + Ap1: 2016-07","test_object_zh":"水","technique_zh":"氢化物发生原子吸收光谱法（HGAAS）"},{"_id":"6a5dc9bbf1c10c8ce825df4c","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie metali","methodology_en":"Metal concentrations","parameters":[{"name":"Al","range":"(5,0 – 250) μg/l"},{"name":"Cd","range":"(0, 50 – 10) μg/l"},{"name":"Cr","range":"(2,0 – 50) μg/l"},{"name":"Cu","range":"(0,0050 – 0,50) mg/l"},{"name":"Pb","range":"(2,0 – 100) μg/l"},{"name":"Ni","range":"(5,0 – 250) μg/l"},{"name":"Mn","range":"(5,0 – 250) μg/l"},{"name":"Ag","range":"(0,0010 – 0,050) mg/l"}],"parameters_en":[{"name":"Al","range":"(5,0 – 250) μg/l"},{"name":"Cd","range":"(0, 50 – 10) μg/l"},{"name":"Cr","range":"(2,0 – 50) μg/l"},{"name":"Cu","range":"(0,0050 – 0,50) mg/l"},{"name":"Pb","range":"(2,0 – 100) μg/l"},{"name":"Ni","range":"(5,0 – 250) μg/l"},{"name":"Mn","range":"(5,0 – 250) μg/l"},{"name":"Ag","range":"(0,0010 – 0,050) mg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)"],"technique_en":"Electrothermal atomization atomic absorption spectrometry (ETAAS)","computed":[],"computed_en":[],"activity":"Stężenie metali\nZakres:\nAl (5,0 – 250) μg/l\nCd (0, 50 – 10) μg/l\nCr (2,0 – 50) μg/l\nCu (0,0050 – 0,50) mg/l\nPb (2,0 – 100) μg/l\nNi (5,0 – 250) μg/l\nMn (5,0 – 250) μg/l\nAg (0,0010 – 0,050) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","reference":"PN-EN ISO 15586:2005","norm_bases":["PN-EN ISO 15586:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie metali\nZakres:\nAl (5,0 – 250) μg/l\nCd (0, 50 – 10) μg/l\nCr (2,0 – 50) μg/l\nCu (0,0050 – 0,50) mg/l\nPb (2,0 – 100) μg/l\nNi (5,0 – 250) μg/l\nMn (5,0 – 250) μg/l\nAg (0,0010 – 0,050) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS) PN-EN ISO 15586:2005 Woda Stezenie metali\nZakres:\nAl (5,0 – 250) μg/l\nCd (0, 50 – 10) μg/l\nCr (2,0 – 50) μg/l\nCu (0,0050 – 0,50) mg/l\nPb (2,0 – 100) μg/l\nNi (5,0 – 250) μg/l\nMn (5,0 – 250) μg/l\nAg (0,0010 – 0,050) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacja elektrotermiczna (ETAAS) PN-EN ISO 15586:2005","categories":["materials","water"],"row_index":107,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Metal concentrations Electrothermal atomization atomic absorption spectrometry (ETAAS) Al Cd Cr Cu Pb Ni Mn Ag PN-EN ISO 15586:2005","methodology_zh":"金属浓度","parameters_zh":[{"name":"Al","range":"(5,0 – 250) μg/l"},{"name":"Cd","range":"(0, 50 – 10) μg/l"},{"name":"Cr","range":"(2,0 – 50) μg/l"},{"name":"Cu","range":"(0,0050 – 0,50) mg/l"},{"name":"Pb","range":"(2,0 – 100) μg/l"},{"name":"Ni","range":"(5,0 – 250) μg/l"},{"name":"Mn","range":"(5,0 – 250) μg/l"},{"name":"Ag","range":"(0,0010 – 0,050) mg/l"}],"search_zh":"水 金属浓度 电热原子化原子吸收光谱法（ETAAS） Al Cd Cr Cu Pb Ni Mn Ag PN-EN ISO 15586:2005","technique_zh":"电热原子化原子吸收光谱法（ETAAS）","test_object_zh":"水"},{"_id":"6a5dc9bbf1c10c8ce825df4d","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie cynku","methodology_en":"Zinc concentration","parameters":[{"name":"Zakres","range":"(0,40 – 1,50) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,40 – 1,50) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"technique_en":"Flame atomic absorption spectrometry (FAAS)","computed":[],"computed_en":[],"activity":"Stężenie cynku\nZakres (0,40 – 1,50) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 8288:2002 metoda A","norm_bases":["PN-ISO 8288:2002 metoda A"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie cynku\nZakres (0,40 – 1,50) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 metoda A Woda Stezenie cynku\nZakres (0,40 – 1,50) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 metoda A","categories":["water"],"row_index":108,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Zinc concentration Flame atomic absorption spectrometry (FAAS) Range PN-ISO 8288:2002 metoda A","parameters_zh":[{"name":"范围","range":"(0,40 – 1,50) mg/l"}],"search_zh":"水 锌浓度 火焰原子吸收光谱法（FAAS） 范围 PN-ISO 8288:2002 metoda A","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"水","methodology_zh":"锌浓度"},{"_id":"6a5dc9bbf1c10c8ce825df4e","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie sodu","methodology_en":"Sodium concentration","parameters":[{"name":"Zakres","range":"(0,10 – 250) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,10 – 250) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"technique_en":"Flame atomic absorption spectrometry (FAAS)","computed":[],"computed_en":[],"activity":"Stężenie sodu\nZakres (0,10 – 250) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 9964-1:1994 + Ak:1997+Ap1:2009","norm_bases":["PN-ISO 9964-1:1994 + Ak:1997+Ap1:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie sodu\nZakres (0,10 – 250) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 9964-1:1994 + Ak:1997+Ap1:2009 Woda Stezenie sodu\nZakres (0,10 – 250) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 9964-1:1994 + Ak:1997+Ap1:2009","categories":["water"],"row_index":109,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Sodium concentration Flame atomic absorption spectrometry (FAAS) Range PN-ISO 9964-1:1994 + Ak:1997+Ap1:2009","parameters_zh":[{"name":"范围","range":"(0,10 – 250) mg/l"}],"search_zh":"水 钠浓度 火焰原子吸收光谱法（FAAS） 范围 PN-ISO 9964-1:1994 + Ak:1997+Ap1:2009","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"水","methodology_zh":"钠浓度"},{"_id":"6a5dc9bbf1c10c8ce825df4f","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie potasu","methodology_en":"Potassium concentration","parameters":[{"name":"Zakres","range":"(0,10 – 150) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,10 – 150) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"technique_en":"Flame atomic absorption spectrometry (FAAS)","computed":[],"computed_en":[],"activity":"Stężenie potasu\nZakres (0,10 – 150) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 9964-2:1994 + Ak:1997","norm_bases":["PN-ISO 9964-2:1994 + Ak:1997"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie potasu\nZakres (0,10 – 150) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 9964-2:1994 + Ak:1997 Woda Stezenie potasu\nZakres (0,10 – 150) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 9964-2:1994 + Ak:1997","categories":["water"],"row_index":110,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Potassium concentration Flame atomic absorption spectrometry (FAAS) Range PN-ISO 9964-2:1994 + Ak:1997","parameters_zh":[{"name":"范围","range":"(0,10 – 150) mg/l"}],"search_zh":"水 钾浓度 火焰原子吸收光谱法（FAAS） 范围 PN-ISO 9964-2:1994 + Ak:1997","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"水","methodology_zh":"钾浓度"},{"_id":"6a5dc9bbf1c10c8ce825df50","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie magnezu","methodology_en":"Magnesium concentration","parameters":[{"name":"Zakres","range":"(0,10 – 50) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,10 – 50) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"technique_en":"Flame atomic absorption spectrometry (FAAS)","computed":[],"computed_en":[],"activity":"Stężenie magnezu\nZakres (0,10 – 50) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-EN ISO 7980:2002","norm_bases":["PN-EN ISO 7980:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie magnezu\nZakres (0,10 – 50) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN ISO 7980:2002 Woda Stezenie magnezu\nZakres (0,10 – 50) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN ISO 7980:2002","categories":["water"],"row_index":111,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Magnesium concentration Flame atomic absorption spectrometry (FAAS) Range PN-EN ISO 7980:2002","parameters_zh":[{"name":"范围","range":"(0,10 – 50) mg/l"}],"search_zh":"水 镁浓度 火焰原子吸收光谱法（FAAS） 范围 PN-EN ISO 7980:2002","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"水","methodology_zh":"镁浓度"},{"_id":"6a5dc9bbf1c10c8ce825df51","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie bromianów","methodology_en":"Bromate concentration","parameters":[{"name":"Zakres","range":"(3,0 – 100) μg/l"}],"parameters_en":[{"name":"Range","range":"(3,0 – 100) μg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"technique_en":"Ion chromatography with conductometric detection (IC-CD)","computed":[],"computed_en":[],"activity":"Stężenie bromianów\nZakres (3,0 – 100) μg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PL-PB-25 wydanie 05 z dnia 11.09.2025 r.","norm_bases":["PL-PB-25 wydanie 05 z dnia 11.09.2025 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie bromianów\nZakres (3,0 – 100) μg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PL-PB-25 wydanie 05 z dnia 11.09.2025 r. Woda Stezenie bromianow\nZakres (3,0 – 100) μg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PL-PB-25 wydanie 05 z dnia 11.09.2025 r.","categories":["water"],"row_index":112,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Bromate concentration Ion chromatography with conductometric detection (IC-CD) Range PL-PB-25 wydanie 05 z dnia 11.09.2025 r.","parameters_zh":[{"name":"范围","range":"(3,0 – 100) μg/l"}],"search_zh":"水 溴酸盐浓度 离子色谱-电导检测法（IC-CD） 范围 PL-PB-25 wydanie 05 z dnia 11.09.2025 r.","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水","methodology_zh":"溴酸盐浓度"},{"_id":"6a5dc9bbf1c10c8ce825df52","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie anionów","methodology_en":"Anion concentrations","parameters":[{"name":"Azotyny","range":"(0,050 – 1,0) mg/l"},{"name":"Chlorki","range":"(1,5 – 250) mg/l"},{"name":"Bromki","range":"(0,050 – 1,0) mg/l"},{"name":"Fluorki","range":"(0,050 – 8,0 ) mg/l"},{"name":"Fosforany","range":"(0,10 – 2,0) mg/l"},{"name":"Siarczany","range":"(2,5 – 250) mg/l"}],"parameters_en":[{"name":"Nitrites","range":"(0,050 – 1,0) mg/l"},{"name":"Chlorides","range":"(1,5 – 250) mg/l"},{"name":"Bromides","range":"(0,050 – 1,0) mg/l"},{"name":"Fluorides","range":"(0,050 – 8,0 ) mg/l"},{"name":"Phosphates","range":"(0,10 – 2,0) mg/l"},{"name":"Sulfates","range":"(2,5 – 250) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"technique_en":"Ion chromatography with conductometric detection (IC-CD)","computed":[],"computed_en":[],"activity":"Stężenie anionów\nZakres:\nAzotyny (0,050 – 1,0) mg/l\nChlorki (1,5 – 250) mg/l\nBromki (0,050 – 1,0) mg/l\nFluorki (0,050 – 8,0 ) mg/l\nFosforany (0,10 – 2,0) mg/l\nSiarczany (2,5 – 250) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009 + AC:2012","norm_bases":["PN-EN ISO 10304-1:2009 + AC:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie anionów\nZakres:\nAzotyny (0,050 – 1,0) mg/l\nChlorki (1,5 – 250) mg/l\nBromki (0,050 – 1,0) mg/l\nFluorki (0,050 – 8,0 ) mg/l\nFosforany (0,10 – 2,0) mg/l\nSiarczany (2,5 – 250) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009 + AC:2012 Woda Stezenie anionow\nZakres:\nAzotyny (0,050 – 1,0) mg/l\nChlorki (1,5 – 250) mg/l\nBromki (0,050 – 1,0) mg/l\nFluorki (0,050 – 8,0 ) mg/l\nFosforany (0,10 – 2,0) mg/l\nSiarczany (2,5 – 250) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009 + AC:2012","categories":["water"],"row_index":113,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Anion concentrations Ion chromatography with conductometric detection (IC-CD) Nitrites Chlorides Bromides Fluorides Phosphates Sulfates PN-EN ISO 10304-1:2009 + AC:2012","methodology_zh":"阴离子浓度","parameters_zh":[{"name":"亚硝酸盐","range":"(0,050 – 1,0) mg/l"},{"name":"氯化物","range":"(1,5 – 250) mg/l"},{"name":"Bromki","range":"(0,050 – 1,0) mg/l"},{"name":"氟化物","range":"(0,050 – 8,0 ) mg/l"},{"name":"磷酸盐","range":"(0,10 – 2,0) mg/l"},{"name":"硫酸盐","range":"(2,5 – 250) mg/l"}],"search_zh":"水 阴离子浓度 离子色谱-电导检测法（IC-CD） 亚硝酸盐 氯化物 氟化物 磷酸盐 硫酸盐 PN-EN ISO 10304-1:2009 + AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水"},{"_id":"6a5dc9bbf1c10c8ce825df53","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie anionów","methodology_en":"Anion concentrations","parameters":[{"name":"Chloryny","range":"(0,010 – 0,50) mg/l"},{"name":"Chlorany","range":"(0,025 – 0,50) mg/l"}],"parameters_en":[{"name":"Chlorites","range":"(0,010 – 0,50) mg/l"},{"name":"Chlorates","range":"(0,025 – 0,50) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"technique_en":"Ion chromatography with conductometric detection (IC-CD)","computed":[],"computed_en":[],"activity":"Stężenie anionów\nZakres:\nChloryny (0,010 – 0,50) mg/l\nChlorany (0,025 – 0,50) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-4:2022-08","norm_bases":["PN-EN ISO 10304-4:2022-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie anionów\nZakres:\nChloryny (0,010 – 0,50) mg/l\nChlorany (0,025 – 0,50) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-4:2022-08 Woda Stezenie anionow\nZakres:\nChloryny (0,010 – 0,50) mg/l\nChlorany (0,025 – 0,50) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-4:2022-08","categories":["water"],"row_index":114,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Anion concentrations Ion chromatography with conductometric detection (IC-CD) Chlorites Chlorates PN-EN ISO 10304-4:2022-08","methodology_zh":"阴离子浓度","search_zh":"水 阴离子浓度 离子色谱-电导检测法（IC-CD） 亚氯酸盐 氯酸盐 PN-EN ISO 10304-4:2022-08","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水","parameters_zh":[{"name":"亚氯酸盐","range":"(0,010 – 0,50) mg/l"},{"name":"氯酸盐","range":"(0,025 – 0,50) mg/l"}]},{"_id":"6a5dc9bbf1c10c8ce825df54","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Suma chloranów i chlorynów (z obliczeń)","methodology_en":"Sum of chlorates and chlorites (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Suma chloranów i chlorynów (z obliczeń)","reference":"PL-PB-25 wydanie 05 z dnia 11.09.2025 r.","norm_bases":["PL-PB-25 wydanie 05 z dnia 11.09.2025 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Suma chloranów i chlorynów (z obliczeń) PL-PB-25 wydanie 05 z dnia 11.09.2025 r. Woda Suma chloranow i chlorynow (z obliczen) PL-PB-25 wydanie 05 z dnia 11.09.2025 r.","categories":["water"],"row_index":115,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Sum of chlorates and chlorites (calculated) PL-PB-25 wydanie 05 z dnia 11.09.2025 r.","search_zh":"水 氯酸盐与亚氯酸盐总量（由计算得出） PL-PB-25 wydanie 05 z dnia 11.09.2025 r.","test_object_zh":"水","methodology_zh":"氯酸盐与亚氯酸盐总量（由计算得出）"},{"_id":"6a5dc9bbf1c10c8ce825df55","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)","methodology_en":"Concentration of polycyclic aromatic hydrocarbons (PAH)","parameters":[{"name":"benzo(a)piren","range":"(0,0020 – 0,10) μg/l"},{"name":"fluoranten","range":"(0,0020 – 0,10) μg/l"},{"name":"benzo(b)fluoranten"},{"name":"Zakres","range":"(0,0020 – 0,10) μg/l"},{"name":"benzo(k)fluoranten","range":"(0,0020 – 0,10) μg/l"},{"name":"benzo(ghi)perylen","range":"(0,0020 – 0,10) μg/l"},{"name":"indeno","range":"(1,2,3-c,d)piren"},{"name":"(0,0020 – 0,10) μg/l"},{"name":"Suma WWA: (benzo(b)fluoranten, benzo(k)fluoranten, benzo(g,h,i)perylen, indeno","range":"(1,2,3-cd)piren)"},{"name":"(z obliczeń)"}],"parameters_en":[{"name":"benzo(a)pyrene","range":"(0,0020 – 0,10) μg/l"},{"name":"fluoranthene","range":"(0,0020 – 0,10) μg/l"},{"name":"benzo(b)fluoranthene"},{"name":"Range","range":"(0,0020 – 0,10) μg/l"},{"name":"benzo(k)fluoranthene","range":"(0,0020 – 0,10) μg/l"},{"name":"benzo(ghi)perylene","range":"(0,0020 – 0,10) μg/l"},{"name":"indeno","range":"(1,2,3-c,d)piren"},{"name":"(0,0020 – 0,10) μg/l"},{"name":"Sum of PAH: (benzo(b)fluoranthene, benzo(k)fluoranthene, benzo(g,h,i)perylene, indeno","range":"(1,2,3-cd)piren)"},{"name":"(calculated)"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","computed":[],"computed_en":[],"activity":"Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)\nZakres:\nbenzo(a)piren (0,0020 – 0,10) μg/l\nfluoranten (0,0020 – 0,10) μg/l\nbenzo(b)fluoranten\nZakres (0,0020 – 0,10) μg/l\nbenzo(k)fluoranten (0,0020 – 0,10) μg/l\nbenzo(ghi)perylen (0,0020 – 0,10) μg/l\nindeno (1,2,3-c,d)piren\n(0,0020 – 0,10) μg/l\nSuma WWA: (benzo(b)fluoranten, benzo(k)fluoranten, benzo(g,h,i)perylen, indeno (1,2,3-cd)piren)\n(z obliczeń)\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"PL-PB-24 wydanie 03 z dnia 03.06.2019 r.","norm_bases":["PL-PB-24 wydanie 03 z dnia 03.06.2019 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)\nZakres:\nbenzo(a)piren (0,0020 – 0,10) μg/l\nfluoranten (0,0020 – 0,10) μg/l\nbenzo(b)fluoranten\nZakres (0,0020 – 0,10) μg/l\nbenzo(k)fluoranten (0,0020 – 0,10) μg/l\nbenzo(ghi)perylen (0,0020 – 0,10) μg/l\nindeno (1,2,3-c,d)piren\n(0,0020 – 0,10) μg/l\nSuma WWA: (benzo(b)fluoranten, benzo(k)fluoranten, benzo(g,h,i)perylen, indeno (1,2,3-cd)piren)\n(z obliczeń)\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) PL-PB-24 wydanie 03 z dnia 03.06.2019 r. Woda Stezenie wielopierscieniowych weglowodorow aromatycznych (WWA)\nZakres:\nbenzo(a)piren (0,0020 – 0,10) μg/l\nfluoranten (0,0020 – 0,10) μg/l\nbenzo(b)fluoranten\nZakres (0,0020 – 0,10) μg/l\nbenzo(k)fluoranten (0,0020 – 0,10) μg/l\nbenzo(ghi)perylen (0,0020 – 0,10) μg/l\nindeno (1,2,3-c,d)piren\n(0,0020 – 0,10) μg/l\nSuma WWA: (benzo(b)fluoranten, benzo(k)fluoranten, benzo(g,h,i)perylen, indeno (1,2,3-cd)piren)\n(z obliczen)\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) PL-PB-24 wydanie 03 z dnia 03.06.2019 r.","categories":["water"],"row_index":116,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Concentration of polycyclic aromatic hydrocarbons (PAH) Gas chromatography with mass spectrometry detection (GC-MS) benzo(a)pyrene fluoranthene benzo(b)fluoranthene Range benzo(k)fluoranthene benzo(ghi)perylene indeno (0,0020 – 0,10) μg/l Sum of PAH: (benzo(b)fluoranthene, benzo(k)fluoranthene, benzo(g,h,i)perylene, indeno (calculated) PL-PB-24 wydanie 03 z dnia 03.06.2019 r.","parameters_zh":[{"name":"苯并（a）芘","range":"(0,0020 – 0,10) μg/l"},{"name":"荧蒽","range":"(0,0020 – 0,10) μg/l"},{"name":"苯并（b）荧蒽"},{"name":"范围","range":"(0,0020 – 0,10) μg/l"},{"name":"苯并（k）荧蒽","range":"(0,0020 – 0,10) μg/l"},{"name":"苯并（ghi）苝","range":"(0,0020 – 0,10) μg/l"},{"name":"茚","range":"(1,2,3-c,d)piren"},{"name":"(0,0020 – 0,10) μg/l"},{"name":"Suma WWA: (benzo(b)fluoranten, benzo(k)fluoranten, benzo(g,h,i)perylen, indeno","range":"(1,2,3-cd)piren)"},{"name":"（计算得出）"}],"search_zh":"水 多环芳烃（PAHs）浓度 气相色谱-质谱法（GC-MS） 苯并（a）芘 荧蒽 苯并（b）荧蒽 范围 苯并（k）荧蒽 苯并（ghi）苝 茚 （计算得出） PL-PB-24 wydanie 03 z dnia 03.06.2019 r.","technique_zh":"气相色谱-质谱法（GC-MS）","test_object_zh":"水","methodology_zh":"多环芳烃（PAHs）浓度"},{"_id":"6a5dc9bbf1c10c8ce825df56","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie pierwiastków","methodology_en":"Element concentration","parameters":[{"name":"Arsen","range":"(2,0 – 100) μg/l"},{"name":"Selen","range":"(2,0 – 100) μg/l"},{"name":"Antymon","range":"(1,0 – 20) μg/l"},{"name":"Bor","range":"(0,08 – 4,0) mg/l"}],"parameters_en":[{"name":"Arsenic","range":"(2,0 – 100) μg/l"},{"name":"Selenium","range":"(2,0 – 100) μg/l"},{"name":"Antimony","range":"(1,0 – 20) μg/l"},{"name":"Boron","range":"(0,08 – 4,0) mg/l"}],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","computed":[],"computed_en":[],"activity":"Stężenie pierwiastków\nZakres:\nArsen (2,0 – 100) μg/l\nSelen (2,0 – 100) μg/l\nAntymon (1,0 – 20) μg/l\nBor (0,08 – 4,0) mg/l\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"PN-EN ISO 17294-2:2024-04","norm_bases":["PN-EN ISO 17294-2:2024-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie pierwiastków\nZakres:\nArsen (2,0 – 100) μg/l\nSelen (2,0 – 100) μg/l\nAntymon (1,0 – 20) μg/l\nBor (0,08 – 4,0) mg/l\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) PN-EN ISO 17294-2:2024-04 Woda Stezenie pierwiastkow\nZakres:\nArsen (2,0 – 100) μg/l\nSelen (2,0 – 100) μg/l\nAntymon (1,0 – 20) μg/l\nBor (0,08 – 4,0) mg/l\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) PN-EN ISO 17294-2:2024-04","categories":["water"],"row_index":117,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Element concentration Inductively coupled plasma mass spectrometry (ICP-MS) Arsenic Selenium Antimony Boron PN-EN ISO 17294-2:2024-04","methodology_zh":"元素浓度","search_zh":"水 元素浓度 电感耦合等离子体质谱法（ICP-MS） 砷 硒 锑 硼 PN-EN ISO 17294-2:2024-04","technique_zh":"电感耦合等离子体质谱法（ICP-MS）","test_object_zh":"水","parameters_zh":[{"name":"砷","range":"(2,0 – 100) μg/l"},{"name":"硒","range":"(2,0 – 100) μg/l"},{"name":"锑","range":"(1,0 – 20) μg/l"},{"name":"硼","range":"(0,08 – 4,0) mg/l"}]},{"_id":"6a5dc9bbf1c10c8ce825df57","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie lotnych związków organicznych","methodology_en":"Concentration of volatile organic compounds","parameters":[{"name":"Trichloroeten","range":"(0,10 – 10) μg/l"},{"name":"Tetrachloroeten","range":"(0,10 – 10) μg/l"},{"name":"Suma trichloroeten i tetrachloroeten (z obliczeń) Czterochlorek węgla","range":"(0,10 – 10) μg/l"}],"parameters_en":[{"name":"Trichloroethene","range":"(0,10 – 10) μg/l"},{"name":"Tetrachloroethene","range":"(0,10 – 10) μg/l"},{"name":"Sum of trichloroethene and tetrachloroethene (calculated) Carbon tetrachloride","range":"(0,10 – 10) μg/l"}],"technique":"Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","techniques":["Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)"],"technique_en":"Gas chromatography with electron capture detection (GC-ECD)","computed":[],"computed_en":[],"activity":"Stężenie lotnych związków organicznych\nZakres:\nTrichloroeten (0,10 – 10) μg/l\nTetrachloroeten (0,10 – 10) μg/l\nSuma trichloroeten i tetrachloroeten (z obliczeń) Czterochlorek węgla (0,10 – 10) μg/l\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","reference":"PN-EN ISO 10301:2002","norm_bases":["PN-EN ISO 10301:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie lotnych związków organicznych\nZakres:\nTrichloroeten (0,10 – 10) μg/l\nTetrachloroeten (0,10 – 10) μg/l\nSuma trichloroeten i tetrachloroeten (z obliczeń) Czterochlorek węgla (0,10 – 10) μg/l\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) PN-EN ISO 10301:2002 Woda Stezenie lotnych zwiazkow organicznych\nZakres:\nTrichloroeten (0,10 – 10) μg/l\nTetrachloroeten (0,10 – 10) μg/l\nSuma trichloroeten i tetrachloroeten (z obliczen) Czterochlorek wegla (0,10 – 10) μg/l\nMetoda chromatografii gazowej z detekcja wychwytu elektronow (GC-ECD) PN-EN ISO 10301:2002","categories":["water"],"row_index":118,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Concentration of volatile organic compounds Gas chromatography with electron capture detection (GC-ECD) Trichloroethene Tetrachloroethene Sum of trichloroethene and tetrachloroethene (calculated) Carbon tetrachloride PN-EN ISO 10301:2002","search_zh":"水 挥发性有机物浓度 气相色谱-电子捕获检测法（GC-ECD） 三氯乙烯 四氯乙烯 PN-EN ISO 10301:2002","technique_zh":"气相色谱-电子捕获检测法（GC-ECD）","test_object_zh":"水","methodology_zh":"挥发性有机物浓度","parameters_zh":[{"name":"三氯乙烯","range":"(0,10 – 10) μg/l"},{"name":"四氯乙烯","range":"(0,10 – 10) μg/l"},{"name":"Suma trichloroeten i tetrachloroeten (z obliczeń) Czterochlorek węgla","range":"(0,10 – 10) μg/l"}]},{"_id":"6a5dc9bbf1c10c8ce825df58","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie ogólnego węgla organicznego (TOC)","methodology_en":"Total organic carbon (TOC) concentration","parameters":[{"name":"Zakres","range":"(1,40 – 18,6) mg/l"}],"parameters_en":[{"name":"Range","range":"(1,40 – 18,6) mg/l"}],"technique":"Metoda spektrometrii w zakresie podczerwieni IR","techniques":["Metoda spektrometrii w zakresie podczerwieni IR"],"technique_en":"Spectrometry method in the infrared range IR","computed":[],"computed_en":[],"activity":"Stężenie ogólnego węgla organicznego (TOC)\nZakres (1,40 – 18,6) mg/l\nMetoda spektrometrii w zakresie podczerwieni IR","reference":"PN-EN 1484:1999","norm_bases":["PN-EN 1484:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie ogólnego węgla organicznego (TOC)\nZakres (1,40 – 18,6) mg/l\nMetoda spektrometrii w zakresie podczerwieni IR PN-EN 1484:1999 Woda Stezenie ogolnego wegla organicznego (TOC)\nZakres (1,40 – 18,6) mg/l\nMetoda spektrometrii w zakresie podczerwieni IR PN-EN 1484:1999","categories":["water"],"row_index":119,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Total organic carbon (TOC) concentration Spectrometry method in the infrared range IR Range PN-EN 1484:1999","parameters_zh":[{"name":"范围","range":"(1,40 – 18,6) mg/l"}],"search_zh":"水 总有机碳（TOC）浓度 红外光谱法 IR 范围 PN-EN 1484:1999","test_object_zh":"水","technique_zh":"红外光谱法 IR","methodology_zh":"总有机碳（TOC）浓度"},{"_id":"6a5dc9bbf1c10c8ce825df59","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach)","test_object_en":"Water (including swimming pool water)","methodology":"Stężenie lotnych związków organicznych","methodology_en":"Concentration of volatile organic compounds","parameters":[{"name":"Chloroform (trichlorometan)"},{"name":"Zakres","range":"(1,0 – 120) μg/l"},{"name":"Dibromochlorometan","range":"(1,0 – 120) μg/l"},{"name":"Bromodichlorometan","range":"(1,0 – 120) μg/l"},{"name":"Bromoform","range":"(1,0 – 120) μg/l"},{"name":"Suma THM (powyższe cztery związki) (z obliczeń)"}],"parameters_en":[{"name":"Chloroform (trichloromethane)"},{"name":"Range","range":"(1,0 – 120) μg/l"},{"name":"Dibromochloromethane","range":"(1,0 – 120) μg/l"},{"name":"Bromodichloromethane","range":"(1,0 – 120) μg/l"},{"name":"Bromoform","range":"(1,0 – 120) μg/l"},{"name":"Sum of THM (the above four compounds) (calculated)"}],"technique":"Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","techniques":["Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)"],"technique_en":"Gas chromatography with electron capture detection (GC-ECD)","computed":[],"computed_en":[],"activity":"Stężenie lotnych związków organicznych\nZakres:\nChloroform (trichlorometan)\nZakres (1,0 – 120) μg/l\nDibromochlorometan (1,0 – 120) μg/l\nBromodichlorometan (1,0 – 120) μg/l\nBromoform (1,0 – 120) μg/l\nSuma THM (powyższe cztery związki) (z obliczeń)\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","reference":"PN-EN ISO 10301:2002","norm_bases":["PN-EN ISO 10301:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach) Stężenie lotnych związków organicznych\nZakres:\nChloroform (trichlorometan)\nZakres (1,0 – 120) μg/l\nDibromochlorometan (1,0 – 120) μg/l\nBromodichlorometan (1,0 – 120) μg/l\nBromoform (1,0 – 120) μg/l\nSuma THM (powyższe cztery związki) (z obliczeń)\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) PN-EN ISO 10301:2002 Woda (w tym woda na plywalniach) Stezenie lotnych zwiazkow organicznych\nZakres:\nChloroform (trichlorometan)\nZakres (1,0 – 120) μg/l\nDibromochlorometan (1,0 – 120) μg/l\nBromodichlorometan (1,0 – 120) μg/l\nBromoform (1,0 – 120) μg/l\nSuma THM (powyzsze cztery zwiazki) (z obliczen)\nMetoda chromatografii gazowej z detekcja wychwytu elektronow (GC-ECD) PN-EN ISO 10301:2002","categories":["water"],"row_index":120,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water (including swimming pool water) Concentration of volatile organic compounds Gas chromatography with electron capture detection (GC-ECD) Chloroform (trichloromethane) Range Dibromochloromethane Bromodichloromethane Bromoform Sum of THM (the above four compounds) (calculated) PN-EN ISO 10301:2002","parameters_zh":[{"name":"Chloroform (trichlorometan)"},{"name":"范围","range":"(1,0 – 120) μg/l"},{"name":"二溴一氯甲烷","range":"(1,0 – 120) μg/l"},{"name":"一溴二氯甲烷","range":"(1,0 – 120) μg/l"},{"name":"三溴甲烷","range":"(1,0 – 120) μg/l"},{"name":"Suma THM (powyższe cztery związki) (z obliczeń)"}],"search_zh":"水（含游泳池水） 挥发性有机物浓度 气相色谱-电子捕获检测法（GC-ECD） 范围 二溴一氯甲烷 一溴二氯甲烷 三溴甲烷 PN-EN ISO 10301:2002","technique_zh":"气相色谱-电子捕获检测法（GC-ECD）","test_object_zh":"水（含游泳池水）","methodology_zh":"挥发性有机物浓度"},{"_id":"6a5dc9bbf1c10c8ce825df5a","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach)","test_object_en":"Water (including swimming pool water)","methodology":"Stężenie anionów","methodology_en":"Anion concentrations","parameters":[{"name":"Azotany","range":"(0,50 – 50) mg/l"}],"parameters_en":[{"name":"Nitrates","range":"(0,50 – 50) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"technique_en":"Ion chromatography with conductometric detection (IC-CD)","computed":[],"computed_en":[],"activity":"Stężenie anionów\nAzotany (0,50 – 50) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009 + AC:2012","norm_bases":["PN-EN ISO 10304-1:2009 + AC:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach) Stężenie anionów\nAzotany (0,50 – 50) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009 + AC:2012 Woda (w tym woda na plywalniach) Stezenie anionow\nAzotany (0,50 – 50) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009 + AC:2012","categories":["water"],"row_index":121,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water (including swimming pool water) Anion concentrations Ion chromatography with conductometric detection (IC-CD) Nitrates PN-EN ISO 10304-1:2009 + AC:2012","methodology_zh":"阴离子浓度","parameters_zh":[{"name":"硝酸盐","range":"(0,50 – 50) mg/l"}],"search_zh":"水（含游泳池水） 阴离子浓度 离子色谱-电导检测法（IC-CD） 硝酸盐 PN-EN ISO 10304-1:2009 + AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水（含游泳池水）"},{"_id":"6a5dc9bbf1c10c8ce825df5b","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Indeks oleju mineralnego","methodology_en":"Mineral oil index","parameters":[{"name":"Zakres","range":"(0,10 – 100) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,10 – 100) mg/l"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Indeks oleju mineralnego\nZakres (0,10 – 100) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN ISO 9377-2:2003","norm_bases":["PN-EN ISO 9377-2:2003"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Indeks oleju mineralnego\nZakres (0,10 – 100) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN ISO 9377-2:2003 Woda, scieki Indeks oleju mineralnego\nZakres (0,10 – 100) mg/l\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN ISO 9377-2:2003","categories":["water","petro"],"row_index":122,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Mineral oil index Gas chromatography with flame ionization detection (GC-FID) Range PN-EN ISO 9377-2:2003","parameters_zh":[{"name":"范围","range":"(0,10 – 100) mg/l"}],"search_zh":"水、废水 矿物油指数 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-EN ISO 9377-2:2003","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"水、废水","methodology_zh":"矿物油指数"},{"_id":"6a5dc9bbf1c10c8ce825df5c","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie cynku","methodology_en":"Zinc concentration","parameters":[{"name":"Zakres","range":"(0,40 – 250) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,40 – 250) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"technique_en":"Flame atomic absorption spectrometry (FAAS)","computed":[],"computed_en":[],"activity":"Stężenie cynku\nZakres (0,40 – 250) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 8288:2002 metoda A","norm_bases":["PN-ISO 8288:2002 metoda A"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie cynku\nZakres (0,40 – 250) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 metoda A Scieki Stezenie cynku\nZakres (0,40 – 250) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 metoda A","categories":["water"],"row_index":123,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Zinc concentration Flame atomic absorption spectrometry (FAAS) Range PN-ISO 8288:2002 metoda A","parameters_zh":[{"name":"范围","range":"(0,40 – 250) mg/l"}],"search_zh":"污水 锌浓度 火焰原子吸收光谱法（FAAS） 范围 PN-ISO 8288:2002 metoda A","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"污水","methodology_zh":"锌浓度"},{"_id":"6a5dc9bbf1c10c8ce825df5d","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie metali:","methodology_en":"Metal concentrations:","parameters":[{"name":"Cd","range":"(0,0005 – 0,04) mg/l"},{"name":"Cr","range":"(0,0020 – 0,20) mg/l"},{"name":"Cu","range":"(0,0050 – 4,0) mg/l"},{"name":"Pb","range":"(0,0020 – 0,40) mg/l"},{"name":"Ni","range":"(0,0050 – 1,0) mg/l"}],"parameters_en":[{"name":"Cd","range":"(0,0005 – 0,04) mg/l"},{"name":"Cr","range":"(0,0020 – 0,20) mg/l"},{"name":"Cu","range":"(0,0050 – 4,0) mg/l"},{"name":"Pb","range":"(0,0020 – 0,40) mg/l"},{"name":"Ni","range":"(0,0050 – 1,0) mg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)"],"technique_en":"Electrothermal atomization atomic absorption spectrometry (ETAAS)","computed":[],"computed_en":[],"activity":"Stężenie metali:\nZakres:\nCd (0,0005 – 0,04) mg/l\nCr (0,0020 – 0,20) mg/l\nCu (0,0050 – 4,0) mg/l\nPb (0,0020 – 0,40) mg/l\nNi (0,0050 – 1,0) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","reference":"PN-EN ISO 15586:2005","norm_bases":["PN-EN ISO 15586:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie metali:\nZakres:\nCd (0,0005 – 0,04) mg/l\nCr (0,0020 – 0,20) mg/l\nCu (0,0050 – 4,0) mg/l\nPb (0,0020 – 0,40) mg/l\nNi (0,0050 – 1,0) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS) PN-EN ISO 15586:2005 Scieki Stezenie metali:\nZakres:\nCd (0,0005 – 0,04) mg/l\nCr (0,0020 – 0,20) mg/l\nCu (0,0050 – 4,0) mg/l\nPb (0,0020 – 0,40) mg/l\nNi (0,0050 – 1,0) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacja elektrotermiczna (ETAAS) PN-EN ISO 15586:2005","categories":["materials","water"],"row_index":124,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Metal concentrations: Electrothermal atomization atomic absorption spectrometry (ETAAS) Cd Cr Cu Pb Ni PN-EN ISO 15586:2005","parameters_zh":[{"name":"Cd","range":"(0,0005 – 0,04) mg/l"},{"name":"Cr","range":"(0,0020 – 0,20) mg/l"},{"name":"Cu","range":"(0,0050 – 4,0) mg/l"},{"name":"Pb","range":"(0,0020 – 0,40) mg/l"},{"name":"Ni","range":"(0,0050 – 1,0) mg/l"}],"search_zh":"污水 金属浓度： 电热原子化原子吸收光谱法（ETAAS） Cd Cr Cu Pb Ni PN-EN ISO 15586:2005","technique_zh":"电热原子化原子吸收光谱法（ETAAS）","test_object_zh":"污水","methodology_zh":"金属浓度："},{"_id":"6a5dc9bbf1c10c8ce825df5e","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie rtęci","methodology_en":"Mercury concentration","parameters":[{"name":"Zakres","range":"(0,0010 – 0,04) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,0010 – 0,04) mg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem wodorków (HGAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem wodorków (HGAAS)"],"technique_en":"Hydride generation atomic absorption spectrometry (HGAAS)","computed":[],"computed_en":[],"activity":"Stężenie rtęci\nZakres (0,0010 – 0,04) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem wodorków (HGAAS)","reference":"PN-EN ISO 12846:2012 z wyłączeniem p.6 + Ap1: 2016-07","norm_bases":["PN-EN ISO 12846:2012 z wyłączeniem p.6 + Ap1: 2016-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie rtęci\nZakres (0,0010 – 0,04) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem wodorków (HGAAS) PN-EN ISO 12846:2012 z wyłączeniem p.6 + Ap1: 2016-07 Scieki Stezenie rteci\nZakres (0,0010 – 0,04) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem wodorkow (HGAAS) PN-EN ISO 12846:2012 z wylaczeniem p.6 + Ap1: 2016-07","categories":["water"],"row_index":125,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Mercury concentration Hydride generation atomic absorption spectrometry (HGAAS) Range PN-EN ISO 12846:2012 z wyłączeniem p.6 + Ap1: 2016-07","methodology_zh":"汞浓度","parameters_zh":[{"name":"范围","range":"(0,0010 – 0,04) mg/l"}],"search_zh":"污水 汞浓度 氢化物发生原子吸收光谱法（HGAAS） 范围 PN-EN ISO 12846:2012 z wyłączeniem p.6 + Ap1: 2016-07","test_object_zh":"污水","technique_zh":"氢化物发生原子吸收光谱法（HGAAS）"},{"_id":"6a5dc9bbf1c10c8ce825df5f","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie ogólnego węgla organicznego (TOC)","methodology_en":"Total organic carbon (TOC) concentration","parameters":[{"name":"Zakres","range":"(4,30 – 380) mg/l"}],"parameters_en":[{"name":"Range","range":"(4,30 – 380) mg/l"}],"technique":"Metoda spektrometrii w zakresie podczerwieni IR","techniques":["Metoda spektrometrii w zakresie podczerwieni IR"],"technique_en":"Spectrometry method in the infrared range IR","computed":[],"computed_en":[],"activity":"Stężenie ogólnego węgla organicznego (TOC)\nZakres (4,30 – 380) mg/l\nMetoda spektrometrii w zakresie podczerwieni IR","reference":"PN-EN 1484:1999","norm_bases":["PN-EN 1484:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie ogólnego węgla organicznego (TOC)\nZakres (4,30 – 380) mg/l\nMetoda spektrometrii w zakresie podczerwieni IR PN-EN 1484:1999 Scieki Stezenie ogolnego wegla organicznego (TOC)\nZakres (4,30 – 380) mg/l\nMetoda spektrometrii w zakresie podczerwieni IR PN-EN 1484:1999","categories":["water"],"row_index":126,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Total organic carbon (TOC) concentration Spectrometry method in the infrared range IR Range PN-EN 1484:1999","parameters_zh":[{"name":"范围","range":"(4,30 – 380) mg/l"}],"search_zh":"污水 总有机碳（TOC）浓度 红外光谱法 IR 范围 PN-EN 1484:1999","test_object_zh":"污水","technique_zh":"红外光谱法 IR","methodology_zh":"总有机碳（TOC）浓度"},{"_id":"6a5dc9bbf1c10c8ce825df60","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Pobieranie próbek do badań mikrobiologicznych","methodology_en":"Sampling for microbiological testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007 z wyłączeniem p. 4.4.4.2; 4.4.5; 4.4.6","norm_bases":["PN-EN ISO 19458:2007 z wyłączeniem p. 4.4.4.2; 4.4.5; 4.4.6"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 z wyłączeniem p. 4.4.4.2; 4.4.5; 4.4.6 Woda Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007 z wylaczeniem p. 4.4.4.2; 4.4.5; 4.4.6","categories":["water","microbiology"],"row_index":127,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Sampling for microbiological testing PN-EN ISO 19458:2007 z wyłączeniem p. 4.4.4.2; 4.4.5; 4.4.6","methodology_zh":"微生物检测用样品采集","search_zh":"水 微生物检测用样品采集 PN-EN ISO 19458:2007 z wyłączeniem p. 4.4.4.2; 4.4.5; 4.4.6","test_object_zh":"水"},{"_id":"6a5dc9bbf1c10c8ce825df61","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Ogólna liczba mikroorganizmów w temp. 22 0C","methodology_en":"Total count of microorganisms at 22 0C","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"technique_en":"Plate method (pour plate)","computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w temp. 22 0C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w temp. 22 0C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w temp. 22 0C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":128,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Total count of microorganisms at 22 0C Plate method (pour plate) PN-EN ISO 6222:2004","search_zh":"生活饮用水 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"生活饮用水"},{"_id":"6a5dc9bbf1c10c8ce825df62","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach)","test_object_en":"Water (including swimming pool water)","methodology":"Ogólna liczba mikroorganizmów w temp. 36 0C","methodology_en":"Total microorganism count at 36 0C","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"technique_en":"Plate method (pour plate)","computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w temp. 36 0C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach) Ogólna liczba mikroorganizmów w temp. 36 0C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda (w tym woda na plywalniach) Ogolna liczba mikroorganizmow w temp. 36 0C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":129,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water (including swimming pool water) Total microorganism count at 36 0C Plate method (pour plate) PN-EN ISO 6222:2004","search_zh":"水（含游泳池水） 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水（含游泳池水）"},{"_id":"6a5dc9bbf1c10c8ce825df63","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Liczba bakterii grupy coli","methodology_en":"Coliform bacteria count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 + A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 + A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 + A1:2017-04 Woda Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 + A1:2017-04","categories":["water","microbiology"],"row_index":130,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 + A1:2017-04","methodology_zh":"大肠菌群计数","search_zh":"水 大肠菌群计数 膜过滤法 PN-EN ISO 9308-1:2014-12 + A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水"},{"_id":"6a5dc9bbf1c10c8ce825df64","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach)","test_object_en":"Water (including swimming pool water)","methodology":"Liczba Escherichia coli","methodology_en":"Escherichia coli count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 + A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 + A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach) Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 + A1:2017-04 Woda (w tym woda na plywalniach) Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 + A1:2017-04","categories":["water","microbiology"],"row_index":131,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water (including swimming pool water) Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 + A1:2017-04","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"水（含游泳池水） 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PN-EN ISO 9308-1:2014-12 + A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水（含游泳池水）"},{"_id":"6a5dc9bbf1c10c8ce825df65","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Liczba enterokoków (paciorkowców kałowych)","methodology_en":"Enterococci (faecal streptococci) count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba enterokoków (paciorkowców kałowych)\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Liczba enterokoków (paciorkowców kałowych)\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda Liczba enterokokow (paciorkowcow kalowych)\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":132,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Enterococci (faecal streptococci) count Membrane filtration method PN-EN ISO 7899-2:2004","search_zh":"水 肠球菌（粪链球菌）数 膜过滤法 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"水","methodology_zh":"肠球菌（粪链球菌）数"},{"_id":"6a5dc9bbf1c10c8ce825df66","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach)","test_object_en":"Water (including swimming pool water)","methodology":"Liczba Pseudomonas aeruginosa","methodology_en":"Pseudomonas aeruginosa count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach) Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009 Woda (w tym woda na plywalniach) Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water"],"row_index":133,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water (including swimming pool water) Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009","methodology_zh":"铜绿假单胞菌计数","search_zh":"水（含游泳池水） 铜绿假单胞菌计数 膜过滤法 PN-EN ISO 16266:2009","technique_zh":"膜过滤法","test_object_zh":"水（含游泳池水）"},{"_id":"6a5dc9bbf1c10c8ce825df67","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach)","test_object_en":"Water (including swimming pool water)","methodology":"Liczba bakterii z rodzaju Legionella","methodology_en":"Count of bacteria of the genus Legionella","parameters":[{"name":"Matryca A; Procedura 5; Pożywka A-BCYE Matryca A; Procedura 7; Pożywka C-GVPC Matryca B; Procedura 7; Pożywka C-GVPC"}],"parameters_en":[{"name":"Matrix A; Procedure 5; Medium A-BCYE Matrix A; Procedure 7; Medium C-GVPC Matrix B; Procedure 7; Medium C-GVPC"}],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba bakterii z rodzaju Legionella\nMatryca A; Procedura 5; Pożywka A-BCYE Matryca A; Procedura 7; Pożywka C-GVPC Matryca B; Procedura 7; Pożywka C-GVPC\nMetoda filtracji membranowej","reference":"PN-EN ISO 11731:2017-08 + Ap1:2019-12","norm_bases":["PN-EN ISO 11731:2017-08 + Ap1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach) Liczba bakterii z rodzaju Legionella\nMatryca A; Procedura 5; Pożywka A-BCYE Matryca A; Procedura 7; Pożywka C-GVPC Matryca B; Procedura 7; Pożywka C-GVPC\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 + Ap1:2019-12 Woda (w tym woda na plywalniach) Liczba bakterii z rodzaju Legionella\nMatryca A; Procedura 5; Pozywka A-BCYE Matryca A; Procedura 7; Pozywka C-GVPC Matryca B; Procedura 7; Pozywka C-GVPC\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 + Ap1:2019-12","categories":["microbiology","water"],"row_index":134,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water (including swimming pool water) Count of bacteria of the genus Legionella Membrane filtration method Matrix A; Procedure 5; Medium A-BCYE Matrix A; Procedure 7; Medium C-GVPC Matrix B; Procedure 7; Medium C-GVPC PN-EN ISO 11731:2017-08 + Ap1:2019-12","search_zh":"水（含游泳池水） 军团菌属细菌计数 膜过滤法 PN-EN ISO 11731:2017-08 + Ap1:2019-12","technique_zh":"膜过滤法","methodology_zh":"军团菌属细菌计数","test_object_zh":"水（含游泳池水）"},{"_id":"6a5dc9bbf1c10c8ce825df68","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Najbardziej prawdopodobna liczba, Escherichia coli","methodology_en":"Most probable number, Escherichia coli","parameters":[],"parameters_en":[],"technique":"Metoda NPL (zminiaturyzowana)","techniques":["Metoda NPL (zminiaturyzowana)"],"technique_en":"MPN method (miniaturized)","computed":[],"computed_en":[],"activity":"Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda NPL (zminiaturyzowana)","reference":"PN-EN ISO 9308-3:2002","norm_bases":["PN-EN ISO 9308-3:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda NPL (zminiaturyzowana) PN-EN ISO 9308-3:2002 Woda Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda NPL (zminiaturyzowana) PN-EN ISO 9308-3:2002","categories":["water","microbiology"],"row_index":135,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Most probable number, Escherichia coli MPN method (miniaturized) PN-EN ISO 9308-3:2002","methodology_zh":"大肠埃希氏菌（Escherichia coli）最可能数（MPN）","search_zh":"水 大肠埃希氏菌（Escherichia coli）最可能数（MPN） PN-EN ISO 9308-3:2002","test_object_zh":"水"},{"_id":"6a5dc9bbf1c10c8ce825df69","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Najbardziej prawdopodobna liczba enterokoków (paciorkowców kałowych)","methodology_en":"Most probable number of enterococci (faecal streptococci)","parameters":[],"parameters_en":[],"technique":"Metoda NPL (zminiaturyzowana)","techniques":["Metoda NPL (zminiaturyzowana)"],"technique_en":"MPN method (miniaturized)","computed":[],"computed_en":[],"activity":"Najbardziej prawdopodobna liczba enterokoków (paciorkowców kałowych)\nMetoda NPL (zminiaturyzowana)","reference":"PN-EN ISO 7899-1:2002","norm_bases":["PN-EN ISO 7899-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Najbardziej prawdopodobna liczba enterokoków (paciorkowców kałowych)\nMetoda NPL (zminiaturyzowana) PN-EN ISO 7899-1:2002 Woda Najbardziej prawdopodobna liczba enterokokow (paciorkowcow kalowych)\nMetoda NPL (zminiaturyzowana) PN-EN ISO 7899-1:2002","categories":["water"],"row_index":136,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Most probable number of enterococci (faecal streptococci) MPN method (miniaturized) PN-EN ISO 7899-1:2002","search_zh":"水 PN-EN ISO 7899-1:2002","test_object_zh":"水"},{"_id":"6a5dc9bbf1c10c8ce825df6a","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Osady ściekowe, środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby","test_object_en":"Sewage sludge, plant cultivation aids: - soil improvers","methodology":"Obecność bakterii z rodzaju Salmonella","methodology_en":"Presence of bacteria of the genus Salmonella","parameters":[],"parameters_en":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"technique_en":"Culture method with biochemical and serological confirmation","computed":[],"computed_en":[],"activity":"Obecność bakterii z rodzaju Salmonella\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PL-PB-23 wydanie 05 z dnia 01.10.2019 r.","norm_bases":["PL-PB-23 wydanie 05 z dnia 01.10.2019 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe, środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby Obecność bakterii z rodzaju Salmonella\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PL-PB-23 wydanie 05 z dnia 01.10.2019 r. Osady sciekowe, srodki wspomagajace uprawe roslin: - srodki poprawiajace wlasciwosci gleby Obecnosc bakterii z rodzaju Salmonella\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PL-PB-23 wydanie 05 z dnia 01.10.2019 r.","categories":["microbiology","water"],"row_index":137,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge, plant cultivation aids: - soil improvers Presence of bacteria of the genus Salmonella Culture method with biochemical and serological confirmation PL-PB-23 wydanie 05 z dnia 01.10.2019 r.","search_zh":"污水污泥、植物栽培辅助制剂：－ 土壤改良剂 沙门氏菌属细菌的检出 培养法结合生化与血清学确认 PL-PB-23 wydanie 05 z dnia 01.10.2019 r.","technique_zh":"培养法结合生化与血清学确认","test_object_zh":"污水污泥、植物栽培辅助制剂：－ 土壤改良剂","methodology_zh":"沙门氏菌属细菌的检出"},{"_id":"6a5dc9bbf1c10c8ce825df6b","lab_id":"69ad52a3de79e566650fb376","country":"PL","accr_number":"AB 680","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Obecność i liczba żywych jaj pasożytów jelitowych ATT (Ascaris spp., Trichuris spp., Toxocara spp.)","methodology_en":"Presence and number of viable eggs of intestinal parasites ATT (Ascaris spp., Trichuris spp., Toxocara spp.)","parameters":[],"parameters_en":[],"technique":"Metoda izolacji, flotacji, inkubacji i obserwacji mikroskopowej","techniques":["Metoda izolacji, flotacji, inkubacji i obserwacji mikroskopowej"],"technique_en":"Isolation, flotation, incubation and microscopic observation method","computed":[],"computed_en":[],"activity":"Obecność i liczba żywych jaj pasożytów jelitowych ATT (Ascaris spp., Trichuris spp., Toxocara spp.)\nMetoda izolacji, flotacji, inkubacji i obserwacji mikroskopowej","reference":"PN-Z-19005:2018-10","norm_bases":["PN-Z-19005:2018-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Obecność i liczba żywych jaj pasożytów jelitowych ATT (Ascaris spp., Trichuris spp., Toxocara spp.)\nMetoda izolacji, flotacji, inkubacji i obserwacji mikroskopowej PN-Z-19005:2018-10 Osady sciekowe Obecnosc i liczba zywych jaj pasozytow jelitowych ATT (Ascaris spp., Trichuris spp., Toxocara spp.)\nMetoda izolacji, flotacji, inkubacji i obserwacji mikroskopowej PN-Z-19005:2018-10","categories":["water","construction"],"row_index":138,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge Presence and number of viable eggs of intestinal parasites ATT (Ascaris spp., Trichuris spp., Toxocara spp.) Isolation, flotation, incubation and microscopic observation method PN-Z-19005:2018-10","search_zh":"污泥 分离、浮选、培养与显微镜观察法 PN-Z-19005:2018-10","test_object_zh":"污泥","technique_zh":"分离、浮选、培养与显微镜观察法"}],"has_pdf":true}