{"lab":{"_id":"69ad52a3de79e566650fb360","accr_number":"AB 661","country":"PL","accr_body":"PCA","address":"ul. Laski 83, 41-306 Dąbrowa Górnicza","categories":["construction"],"city":"Dąbrowa Górnicza","imported_at":"2026-03-08T10:42:43.265Z","methods_count":28,"name":"LABORATORIUM TECHNIKI BUDOWLANEJ Sp. z o.o.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_661.pdf"],"scope_summary":"","search_text":"laboratorium techniki budowlanej sp. z o.o. ul. laski 83, 41-306 dąbrowa górnicza other construction water","status":"active","updated_at":"2026-03-08T14:51:33.896Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-17T21:20:47.677Z","location":{"type":"Point","coordinates":[19.1868,50.3217]},"email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20661,podmiot.html","fields_of_testing":[{"codes":"J/5","pl":"Badania mechaniczne wyrobów budowlanych","en":"Mechanical tests of building products"},{"codes":"N/5","pl":"Badania właściwości fizycznych wyrobów budowlanych","en":"Tests of physical properties of building products"}],"issue":{"no":"22","date":"23.06.2026"},"parse_date":"2026-08-17T21:20:47.677Z","parse_source":"agent-claude-code","map_coord":[50.336667,19.245933],"map_geo":"nominatim-street","lab_locations":[{"name":"LABORATORIUM TECHNIKI BUDOWLANEJ Sp. z o.o.","address":"ul. Laski 83","city":"Dąbrowa Górnicza","postal":"41-306"}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/8bb9e11d25e5736636cff0a3971f8fe4/AB%20661.pdf","has_en":true,"category_counts":{"other":21,"construction":6,"environment":1,"water":1},"category_scores":{"other":15.21,"construction":1.24,"environment":0.03,"water":0.03},"has_zh":true},"methods":[{"_id":"6a837b2faf14b9c0e7b20088","lab_id":"69ad52a3de79e566650fb360","country":"PL","accr_number":"AB 661","accr_body":"PCA","test_object":"Okna i drzwi, Szerokość: do 7000 mm, Wysokość: do 4000 mm","methodology":"Przepuszczalność powietrza","parameters":[{"name":"Zakres","range":"(1,3 - 520) m3/h"}],"technique":null,"techniques":[],"computed":[],"activity":"Przepuszczalność powietrza\nZakres (1,3 - 520) m3/h","reference":"PN-EN 1026:2016 „N”","norm_bases":["PN-EN 1026:2016 „N”"],"lab_section":"Laboratorium Techniki Budowlanej Sp. z o.o.","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Okna i drzwi, Szerokość: do 7000 mm, Wysokość: do 4000 mm Przepuszczalność powietrza\nZakres (1,3 - 520) m3/h PN-EN 1026:2016 „N” Okna i drzwi, Szerokosc: do 7000 mm, Wysokosc: do 4000 mm Przepuszczalnosc powietrza\nZakres (1,3 - 520) m3/h PN-EN 1026:2016 „N”","categories":["other"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air permeability","parameters_en":[{"name":"Range","range":"(1,3 - 520) m3/h"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Windows and doors, Width: up to 7000 mm, Height: up to 4000 mm Air permeability „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. Range PN-EN 1026:2016 „N”","test_object_en":"Windows and doors, Width: up to 7000 mm, Height: up to 4000 mm","parameters_zh":[{"name":"范围","range":"(1,3 - 520) m3/h"}],"regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"透气性 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 范围 PN-EN 1026:2016 „N”","methodology_zh":"透气性"},{"_id":"6a837b2faf14b9c0e7b20089","lab_id":"69ad52a3de79e566650fb360","country":"PL","accr_number":"AB 661","accr_body":"PCA","test_object":"Okna i drzwi, Szerokość: do 7000 mm, Wysokość: do 4000 mm","methodology":"Wodoszczelność","parameters":[{"name":"Zakres","range":"(0 - 3600) Pa"}],"technique":null,"techniques":[],"computed":[],"activity":"Wodoszczelność\nZakres (0 - 3600) Pa","reference":"PN-EN 1027:2016 „N”","norm_bases":["PN-EN 1027:2016 „N”"],"lab_section":"Laboratorium Techniki Budowlanej Sp. z o.o.","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Okna i drzwi, Szerokość: do 7000 mm, Wysokość: do 4000 mm Wodoszczelność\nZakres (0 - 3600) Pa PN-EN 1027:2016 „N” Okna i drzwi, Szerokosc: do 7000 mm, Wysokosc: do 4000 mm Wodoszczelnosc\nZakres (0 - 3600) Pa PN-EN 1027:2016 „N”","categories":["other"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Watertightness","parameters_en":[{"name":"Range","range":"(0 - 3600) Pa"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Windows and doors, Width: up to 7000 mm, Height: up to 4000 mm Watertightness „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. Range PN-EN 1027:2016 „N”","test_object_en":"Windows and doors, Width: up to 7000 mm, Height: up to 4000 mm","parameters_zh":[{"name":"范围","range":"(0 - 3600) Pa"}],"regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"不透水性 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 范围 PN-EN 1027:2016 „N”","methodology_zh":"不透水性"},{"_id":"6a837b2faf14b9c0e7b2008a","lab_id":"69ad52a3de79e566650fb360","country":"PL","accr_number":"AB 661","accr_body":"PCA","test_object":"Okna i drzwi, Szerokość: do 7000 mm, Wysokość: do 4000 mm","methodology":"Odporność na obciążenie wiatrem","parameters":[{"name":"Zakres","range":"(-3600 - +3600) Pa"}],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na obciążenie wiatrem\nZakres (-3600 - +3600) Pa","reference":"PN-EN 12211:2016 „N”","norm_bases":["PN-EN 12211:2016 „N”"],"lab_section":"Laboratorium Techniki Budowlanej Sp. z o.o.","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Okna i drzwi, Szerokość: do 7000 mm, Wysokość: do 4000 mm Odporność na obciążenie wiatrem\nZakres (-3600 - +3600) Pa PN-EN 12211:2016 „N” Okna i drzwi, Szerokosc: do 7000 mm, Wysokosc: do 4000 mm Odpornosc na obciazenie wiatrem\nZakres (-3600 - +3600) Pa PN-EN 12211:2016 „N”","categories":["other"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Resistance to wind load","parameters_en":[{"name":"Range","range":"(-3600 - +3600) Pa"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Windows and doors, Width: up to 7000 mm, Height: up to 4000 mm Resistance to wind load „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. Range PN-EN 12211:2016 „N”","test_object_en":"Windows and doors, Width: up to 7000 mm, Height: up to 4000 mm","parameters_zh":[{"name":"范围","range":"(-3600 - +3600) Pa"}],"regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"抗风荷载性 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 范围 PN-EN 12211:2016 „N”","methodology_zh":"抗风荷载性"},{"_id":"6a837b2faf14b9c0e7b2008b","lab_id":"69ad52a3de79e566650fb360","country":"PL","accr_number":"AB 661","accr_body":"PCA","test_object":"Okna i drzwi","methodology":"Współczynnik przenikania ciepła","parameters":[],"technique":"Metoda obliczeniowa","techniques":["Metoda obliczeniowa"],"computed":[],"activity":"Współczynnik przenikania ciepła\nMetoda obliczeniowa","reference":"PN-EN ISO 10077-1:2017-10 „N”","norm_bases":["PN-EN ISO 10077-1:2017-10 „N”"],"lab_section":"Laboratorium Techniki Budowlanej Sp. z o.o.","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Okna i drzwi Współczynnik przenikania ciepła\nMetoda obliczeniowa PN-EN ISO 10077-1:2017-10 „N” Okna i drzwi Wspolczynnik przenikania ciepla\nMetoda obliczeniowa PN-EN ISO 10077-1:2017-10 „N”","categories":["other"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Thermal transmittance","regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Windows and doors Thermal transmittance Calculation method „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. PN-EN ISO 10077-1:2017-10 „N”","technique_en":"Calculation method","test_object_en":"Windows and doors","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"窗与门 传热系数 计算法 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 PN-EN ISO 10077-1:2017-10 „N”","technique_zh":"计算法","methodology_zh":"传热系数","test_object_zh":"窗与门"},{"_id":"6a837b2faf14b9c0e7b2008c","lab_id":"69ad52a3de79e566650fb360","country":"PL","accr_number":"AB 661","accr_body":"PCA","test_object":"Okna i drzwi, Szerokość: do 4000 mm, Wysokość: do 2500 mm","methodology":"Odporność na obciążenie statyczne","parameters":[{"name":"Zakres","range":"(0 - 15) kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na obciążenie statyczne\nZakres (0 - 15) kN","reference":"PN-EN 1628:2021-11","norm_bases":["PN-EN 1628:2021-11"],"lab_section":"Laboratorium Techniki Budowlanej Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Okna i drzwi, Szerokość: do 4000 mm, Wysokość: do 2500 mm Odporność na obciążenie statyczne\nZakres (0 - 15) kN PN-EN 1628:2021-11 Okna i drzwi, Szerokosc: do 4000 mm, Wysokosc: do 2500 mm Odpornosc na obciazenie statyczne\nZakres (0 - 15) kN PN-EN 1628:2021-11","categories":["other"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Resistance to static load","parameters_en":[{"name":"Range","range":"(0 - 15) kN"}],"search_en":"Windows and doors, Width: up to 4000 mm, Height: up to 2500 mm Resistance to static load Range PN-EN 1628:2021-11","test_object_en":"Windows and doors, Width: up to 4000 mm, Height: up to 2500 mm","parameters_zh":[{"name":"范围","range":"(0 - 15) kN"}],"search_zh":"窗与门，宽度：至 4000 mm，高度：至 2500 mm 范围 PN-EN 1628:2021-11","test_object_zh":"窗与门，宽度：至 4000 mm，高度：至 2500 mm"},{"_id":"6a837b2faf14b9c0e7b2008d","lab_id":"69ad52a3de79e566650fb360","country":"PL","accr_number":"AB 661","accr_body":"PCA","test_object":"Okna i drzwi, Szerokość: do 4000 mm, Wysokość: do 2500 mm","methodology":"Odporność na obciążenie dynamiczne","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na obciążenie dynamiczne","reference":"PN-EN 1629:2021-11","norm_bases":["PN-EN 1629:2021-11"],"lab_section":"Laboratorium Techniki Budowlanej Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Okna i drzwi, Szerokość: do 4000 mm, Wysokość: do 2500 mm Odporność na obciążenie dynamiczne PN-EN 1629:2021-11 Okna i drzwi, Szerokosc: do 4000 mm, Wysokosc: do 2500 mm Odpornosc na obciazenie dynamiczne PN-EN 1629:2021-11","categories":["other"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Resistance to dynamic load","search_en":"Windows and doors, Width: up to 4000 mm, Height: up to 2500 mm Resistance to dynamic load PN-EN 1629:2021-11","test_object_en":"Windows and doors, Width: up to 4000 mm, Height: up to 2500 mm","methodology_zh":"耐动荷载性","search_zh":"窗与门，宽度：至 4000 mm，高度：至 2500 mm 耐动荷载性 PN-EN 1629:2021-11","test_object_zh":"窗与门，宽度：至 4000 mm，高度：至 2500 mm"},{"_id":"6a837b2faf14b9c0e7b2008e","lab_id":"69ad52a3de79e566650fb360","country":"PL","accr_number":"AB 661","accr_body":"PCA","test_object":"Okna i drzwi, Szerokość: do 4000 mm, Wysokość: do 2500 mm","methodology":"Odporność na próby włamania","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na próby włamania","reference":"PN-EN 1630:2021-11","norm_bases":["PN-EN 1630:2021-11"],"lab_section":"Laboratorium Techniki Budowlanej Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Okna i drzwi, Szerokość: do 4000 mm, Wysokość: do 2500 mm Odporność na próby włamania PN-EN 1630:2021-11 Okna i drzwi, Szerokosc: do 4000 mm, Wysokosc: do 2500 mm Odpornosc na proby wlamania PN-EN 1630:2021-11","categories":["other"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Resistance to burglary attempts","search_en":"Windows and doors, Width: up to 4000 mm, Height: up to 2500 mm Resistance to burglary attempts PN-EN 1630:2021-11","test_object_en":"Windows and doors, Width: up to 4000 mm, Height: up to 2500 mm","search_zh":"窗与门，宽度：至 4000 mm，高度：至 2500 mm PN-EN 1630:2021-11","test_object_zh":"窗与门，宽度：至 4000 mm，高度：至 2500 mm"},{"_id":"6a837b2faf14b9c0e7b2008f","lab_id":"69ad52a3de79e566650fb360","country":"PL","accr_number":"AB 661","accr_body":"PCA","test_object":"Okna i drzwi, Szerokość: do 4000 mm, Wysokość: do 2500 mm","methodology":"Odporność na uderzenie ciałem miękkim i ciężkim","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na uderzenie ciałem miękkim i ciężkim","reference":"PN-EN 13049:2024-03","norm_bases":["PN-EN 13049:2024-03"],"lab_section":"Laboratorium Techniki Budowlanej Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Okna i drzwi, Szerokość: do 4000 mm, Wysokość: do 2500 mm Odporność na uderzenie ciałem miękkim i ciężkim PN-EN 13049:2024-03 Okna i drzwi, Szerokosc: do 4000 mm, Wysokosc: do 2500 mm Odpornosc na uderzenie cialem miekkim i ciezkim PN-EN 13049:2024-03","categories":["other"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Resistance to soft and heavy body impact","search_en":"Windows and doors, Width: up to 4000 mm, Height: up to 2500 mm Resistance to soft and heavy body impact PN-EN 13049:2024-03","test_object_en":"Windows and doors, Width: up to 4000 mm, Height: up to 2500 mm","methodology_zh":"软体与硬重物撞击抗力","search_zh":"窗与门，宽度：至 4000 mm，高度：至 2500 mm 软体与硬重物撞击抗力 PN-EN 13049:2024-03","test_object_zh":"窗与门，宽度：至 4000 mm，高度：至 2500 mm"},{"_id":"6a837b2faf14b9c0e7b20090","lab_id":"69ad52a3de79e566650fb360","country":"PL","accr_number":"AB 661","accr_body":"PCA","test_object":"Okna","methodology":"Odporność na skręcanie","parameters":[{"name":"Zakres","range":"(20 - 350) N"}],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na skręcanie\nZakres (20 - 350) N","reference":"PN-EN 14609:2006 „N”","norm_bases":["PN-EN 14609:2006 „N”"],"lab_section":"Laboratorium Techniki Budowlanej Sp. z o.o.","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Okna Odporność na skręcanie\nZakres (20 - 350) N PN-EN 14609:2006 „N” Okna Odpornosc na skrecanie\nZakres (20 - 350) N PN-EN 14609:2006 „N”","categories":["other"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Resistance to torsion","parameters_en":[{"name":"Range","range":"(20 - 350) N"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Windows Resistance to torsion „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. Range PN-EN 14609:2006 „N”","test_object_en":"Windows","parameters_zh":[{"name":"范围","range":"(20 - 350) N"}],"regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"窗 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 范围 PN-EN 14609:2006 „N”","test_object_zh":"窗"},{"_id":"6a837b2faf14b9c0e7b20091","lab_id":"69ad52a3de79e566650fb360","country":"PL","accr_number":"AB 661","accr_body":"PCA","test_object":"Okna","methodology":"Izolacyjność akustyczna","parameters":[],"technique":"Metoda obliczeniowa","techniques":["Metoda obliczeniowa"],"computed":[],"activity":"Izolacyjność akustyczna\nMetoda obliczeniowa","reference":"PN-EN 14351-1+A2:2016 Załącznik B | Procedura LTB PL131 edycja 4 wydanie z dnia 25.03.2019 r.","norm_bases":["PN-EN 14351-1+A2:2016 Załącznik B","Procedura LTB PL131 edycja 4 wydanie z dnia 25.03.2019 r."],"lab_section":"Laboratorium Techniki Budowlanej Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Okna Izolacyjność akustyczna\nMetoda obliczeniowa PN-EN 14351-1+A2:2016 Załącznik B | Procedura LTB PL131 edycja 4 wydanie z dnia 25.03.2019 r. Okna Izolacyjnosc akustyczna\nMetoda obliczeniowa PN-EN 14351-1+A2:2016 Zalacznik B | Procedura LTB PL131 edycja 4 wydanie z dnia 25.03.2019 r.","categories":["construction"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sound insulation","search_en":"Windows Sound insulation Calculation method PN-EN 14351-1+A2:2016 Załącznik B | Procedura LTB PL131 edycja 4 wydanie z dnia 25.03.2019 r.","technique_en":"Calculation method","test_object_en":"Windows","search_zh":"窗 计算法 PN-EN 14351-1+A2:2016 Załącznik B | Procedura LTB PL131 edycja 4 wydanie z dnia 25.03.2019 r.","technique_zh":"计算法","test_object_zh":"窗"},{"_id":"6a837b2faf14b9c0e7b20092","lab_id":"69ad52a3de79e566650fb360","country":"PL","accr_number":"AB 661","accr_body":"PCA","test_object":"Okna i drzwi balkonowe, Szerokość: do 1350 mm, Wysokość: do 2550 mm","methodology":"Siły operacyjne","parameters":[{"name":"Zakres","range":"(4 - 100) N"},{"name":"Zakres","range":"(1 - 10) Nm"}],"technique":null,"techniques":[],"computed":[],"activity":"Siły operacyjne\nZakres:\nZakres (4 - 100) N\nZakres (1 - 10) Nm","reference":"PN-EN 12046-1:2005","norm_bases":["PN-EN 12046-1:2005"],"lab_section":"Laboratorium Techniki Budowlanej Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Okna i drzwi balkonowe, Szerokość: do 1350 mm, Wysokość: do 2550 mm Siły operacyjne\nZakres:\nZakres (4 - 100) N\nZakres (1 - 10) Nm PN-EN 12046-1:2005 Okna i drzwi balkonowe, Szerokosc: do 1350 mm, Wysokosc: do 2550 mm Sily operacyjne\nZakres:\nZakres (4 - 100) N\nZakres (1 - 10) Nm PN-EN 12046-1:2005","categories":["other"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Operating forces","parameters_en":[{"name":"Range","range":"(4 - 100) N"},{"name":"Range","range":"(1 - 10) Nm"}],"search_en":"Windows and balcony doors, Width: up to 1350 mm, Height: up to 2550 mm Operating forces Range Range PN-EN 12046-1:2005","test_object_en":"Windows and balcony doors, Width: up to 1350 mm, Height: up to 2550 mm","parameters_zh":[{"name":"范围","range":"(4 - 100) N"},{"name":"范围","range":"(1 - 10) Nm"}],"search_zh":"操作力 范围 范围 PN-EN 12046-1:2005","methodology_zh":"操作力"},{"_id":"6a837b2faf14b9c0e7b20093","lab_id":"69ad52a3de79e566650fb360","country":"PL","accr_number":"AB 661","accr_body":"PCA","test_object":"Okna i drzwi balkonowe rozwierane, uchylne, rozwierano-uchylne, Szerokość: do 1350 mm, Wysokość: do 2550 mm, Masa: do 150 kg","methodology":"Wielokrotne otwieranie i zamykanie","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wielokrotne otwieranie i zamykanie","reference":"PN-EN 1191:2013-06","norm_bases":["PN-EN 1191:2013-06"],"lab_section":"Laboratorium Techniki Budowlanej Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Okna i drzwi balkonowe rozwierane, uchylne, rozwierano-uchylne, Szerokość: do 1350 mm, Wysokość: do 2550 mm, Masa: do 150 kg Wielokrotne otwieranie i zamykanie PN-EN 1191:2013-06 Okna i drzwi balkonowe rozwierane, uchylne, rozwierano-uchylne, Szerokosc: do 1350 mm, Wysokosc: do 2550 mm, Masa: do 150 kg Wielokrotne otwieranie i zamykanie PN-EN 1191:2013-06","categories":["other"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Repeated opening and closing","search_en":"Repeated opening and closing PN-EN 1191:2013-06"},{"_id":"6a837b2faf14b9c0e7b20094","lab_id":"69ad52a3de79e566650fb360","country":"PL","accr_number":"AB 661","accr_body":"PCA","test_object":"Kształtowniki z niezmiękczonego poli(chlorku winylu)(PVC-U) do produkcji okien i drzwi","methodology":"Wytrzymałość na zginanie przez ściskanie zgrzewanych naroży i połączeń w kształcie T","parameters":[{"name":"Zakres","range":"(0 - 20) kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na zginanie przez ściskanie zgrzewanych naroży i połączeń w kształcie T\nZakres (0 - 20) kN","reference":"PN-EN 514:2018-02","norm_bases":["PN-EN 514:2018-02"],"lab_section":"Laboratorium Techniki Budowlanej Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kształtowniki z niezmiękczonego poli(chlorku winylu)(PVC-U) do produkcji okien i drzwi Wytrzymałość na zginanie przez ściskanie zgrzewanych naroży i połączeń w kształcie T\nZakres (0 - 20) kN PN-EN 514:2018-02 Ksztaltowniki z niezmiekczonego poli(chlorku winylu)(PVC-U) do produkcji okien i drzwi Wytrzymalosc na zginanie przez sciskanie zgrzewanych narozy i polaczen w ksztalcie T\nZakres (0 - 20) kN PN-EN 514:2018-02","categories":["other"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Flexural strength by compression of welded corners and T-joints","parameters_en":[{"name":"Range","range":"(0 - 20) kN"}],"search_en":"Unplasticized poly(vinyl chloride) (PVC-U) profiles for the fabrication of windows and doors Flexural strength by compression of welded corners and T-joints Range PN-EN 514:2018-02","test_object_en":"Unplasticized poly(vinyl chloride) (PVC-U) profiles for the fabrication of windows and doors","parameters_zh":[{"name":"范围","range":"(0 - 20) kN"}],"search_zh":"范围 PN-EN 514:2018-02"},{"_id":"6a837b2faf14b9c0e7b20095","lab_id":"69ad52a3de79e566650fb360","country":"PL","accr_number":"AB 661","accr_body":"PCA","test_object":"Drzwi rozwierane","methodology":"Wytrzymałość na skręcanie statyczne","parameters":[{"name":"Zakres","range":"(200 - 350) N"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na skręcanie statyczne\nZakres (200 - 350) N","reference":"PN-EN 948:2000 „N”","norm_bases":["PN-EN 948:2000 „N”"],"lab_section":"Laboratorium Techniki Budowlanej Sp. z o.o.","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Drzwi rozwierane Wytrzymałość na skręcanie statyczne\nZakres (200 - 350) N PN-EN 948:2000 „N” Drzwi rozwierane Wytrzymalosc na skrecanie statyczne\nZakres (200 - 350) N PN-EN 948:2000 „N”","categories":["other"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Static torsional strength","parameters_en":[{"name":"Range","range":"(200 - 350) N"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Hinged doors Static torsional strength „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. Range PN-EN 948:2000 „N”","test_object_en":"Hinged doors","parameters_zh":[{"name":"范围","range":"(200 - 350) N"}],"regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"静态抗扭强度 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 范围 PN-EN 948:2000 „N”","methodology_zh":"静态抗扭强度"},{"_id":"6a837b2faf14b9c0e7b20096","lab_id":"69ad52a3de79e566650fb360","country":"PL","accr_number":"AB 661","accr_body":"PCA","test_object":"Drzwi rozwierane","methodology":"Izolacyjność akustyczna","parameters":[],"technique":"Metoda obliczeniowa","techniques":["Metoda obliczeniowa"],"computed":[],"activity":"Izolacyjność akustyczna\nMetoda obliczeniowa","reference":"PN-EN 14351-2:2018 Załącznik B | Procedura LTB PL 131 edycja 4 wydanie z dnia 25.03.2019 r.","norm_bases":["PN-EN 14351-2:2018 Załącznik B","Procedura LTB PL 131 edycja 4 wydanie z dnia 25.03.2019 r."],"lab_section":"Laboratorium Techniki Budowlanej Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Drzwi rozwierane Izolacyjność akustyczna\nMetoda obliczeniowa PN-EN 14351-2:2018 Załącznik B | Procedura LTB PL 131 edycja 4 wydanie z dnia 25.03.2019 r. Drzwi rozwierane Izolacyjnosc akustyczna\nMetoda obliczeniowa PN-EN 14351-2:2018 Zalacznik B | Procedura LTB PL 131 edycja 4 wydanie z dnia 25.03.2019 r.","categories":["construction"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sound insulation","search_en":"Hinged doors Sound insulation Calculation method PN-EN 14351-2:2018 Załącznik B | Procedura LTB PL 131 edycja 4 wydanie z dnia 25.03.2019 r.","technique_en":"Calculation method","test_object_en":"Hinged doors","search_zh":"计算法 PN-EN 14351-2:2018 Załącznik B | Procedura LTB PL 131 edycja 4 wydanie z dnia 25.03.2019 r.","technique_zh":"计算法"},{"_id":"6a837b2faf14b9c0e7b20097","lab_id":"69ad52a3de79e566650fb360","country":"PL","accr_number":"AB 661","accr_body":"PCA","test_object":"Drzwi rozwierane, Szerokość: do 1350 mm, Wysokość: do 2550 mm","methodology":"Odporność na obciążenie pionowe","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na obciążenie pionowe","reference":"PN-EN 947:2000","norm_bases":["PN-EN 947:2000"],"lab_section":"Laboratorium Techniki Budowlanej Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Drzwi rozwierane, Szerokość: do 1350 mm, Wysokość: do 2550 mm Odporność na obciążenie pionowe PN-EN 947:2000 Drzwi rozwierane, Szerokosc: do 1350 mm, Wysokosc: do 2550 mm Odpornosc na obciazenie pionowe PN-EN 947:2000","categories":["other"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Resistance to vertical load","search_en":"Hinged doors, Width: up to 1350 mm, Height: up to 2550 mm Resistance to vertical load PN-EN 947:2000","test_object_en":"Hinged doors, Width: up to 1350 mm, Height: up to 2550 mm"},{"_id":"6a837b2faf14b9c0e7b20098","lab_id":"69ad52a3de79e566650fb360","country":"PL","accr_number":"AB 661","accr_body":"PCA","test_object":"Drzwi rozwierane jednoskrzydłowe, Szerokość: do 1350 mm, Wysokość: do 2550 mm","methodology":"Siły operacyjne","parameters":[{"name":"Zakres","range":"(4 - 100) N"},{"name":"Zakres","range":"(1 - 10) Nm"}],"technique":null,"techniques":[],"computed":[],"activity":"Siły operacyjne\nZakres:\nZakres (4 - 100) N\nZakres (1 - 10) Nm","reference":"PN-EN 12046-2:2001","norm_bases":["PN-EN 12046-2:2001"],"lab_section":"Laboratorium Techniki Budowlanej Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Drzwi rozwierane jednoskrzydłowe, Szerokość: do 1350 mm, Wysokość: do 2550 mm Siły operacyjne\nZakres:\nZakres (4 - 100) N\nZakres (1 - 10) Nm PN-EN 12046-2:2001 Drzwi rozwierane jednoskrzydlowe, Szerokosc: do 1350 mm, Wysokosc: do 2550 mm Sily operacyjne\nZakres:\nZakres (4 - 100) N\nZakres (1 - 10) Nm PN-EN 12046-2:2001","categories":["other"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Operating forces","parameters_en":[{"name":"Range","range":"(4 - 100) N"},{"name":"Range","range":"(1 - 10) Nm"}],"search_en":"Single-leaf hinged doors, Width: up to 1350 mm, Height: up to 2550 mm Operating forces Range Range PN-EN 12046-2:2001","test_object_en":"Single-leaf hinged doors, Width: up to 1350 mm, Height: up to 2550 mm","parameters_zh":[{"name":"范围","range":"(4 - 100) N"},{"name":"范围","range":"(1 - 10) Nm"}],"search_zh":"操作力 范围 范围 PN-EN 12046-2:2001","methodology_zh":"操作力"},{"_id":"6a837b2faf14b9c0e7b20099","lab_id":"69ad52a3de79e566650fb360","country":"PL","accr_number":"AB 661","accr_body":"PCA","test_object":"Drzwi rozwierane jednoskrzydłowe, Szerokość: do 1350 mm, Wysokość: do 2550 mm","methodology":"Wielokrotne otwieranie i zamykanie","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wielokrotne otwieranie i zamykanie","reference":"PN-EN 1191:2013-06","norm_bases":["PN-EN 1191:2013-06"],"lab_section":"Laboratorium Techniki Budowlanej Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Drzwi rozwierane jednoskrzydłowe, Szerokość: do 1350 mm, Wysokość: do 2550 mm Wielokrotne otwieranie i zamykanie PN-EN 1191:2013-06 Drzwi rozwierane jednoskrzydlowe, Szerokosc: do 1350 mm, Wysokosc: do 2550 mm Wielokrotne otwieranie i zamykanie PN-EN 1191:2013-06","categories":["other"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Repeated opening and closing","search_en":"Single-leaf hinged doors, Width: up to 1350 mm, Height: up to 2550 mm Repeated opening and closing PN-EN 1191:2013-06","test_object_en":"Single-leaf hinged doors, Width: up to 1350 mm, Height: up to 2550 mm"},{"_id":"6a837b2faf14b9c0e7b2009a","lab_id":"69ad52a3de79e566650fb360","country":"PL","accr_number":"AB 661","accr_body":"PCA","test_object":"Sekcje ram okien i drzwi, ich połączenia z oszkleniem","methodology":"Współczynnik przenikania ciepła","parameters":[],"technique":"Metoda obliczeniowa","techniques":["Metoda obliczeniowa"],"computed":[],"activity":"Współczynnik przenikania ciepła\nMetoda obliczeniowa","reference":"PN-EN ISO 10077-2:2017-10 „N”","norm_bases":["PN-EN ISO 10077-2:2017-10 „N”"],"lab_section":"Laboratorium Techniki Budowlanej Sp. z o.o.","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Sekcje ram okien i drzwi, ich połączenia z oszkleniem Współczynnik przenikania ciepła\nMetoda obliczeniowa PN-EN ISO 10077-2:2017-10 „N” Sekcje ram okien i drzwi, ich polaczenia z oszkleniem Wspolczynnik przenikania ciepla\nMetoda obliczeniowa PN-EN ISO 10077-2:2017-10 „N”","categories":["other"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Thermal transmittance","regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Sections of window and door frames, their connections with glazing Thermal transmittance Calculation method „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. PN-EN ISO 10077-2:2017-10 „N”","technique_en":"Calculation method","test_object_en":"Sections of window and door frames, their connections with glazing","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"传热系数 计算法 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 PN-EN ISO 10077-2:2017-10 „N”","technique_zh":"计算法","methodology_zh":"传热系数"},{"_id":"6a837b2faf14b9c0e7b2009b","lab_id":"69ad52a3de79e566650fb360","country":"PL","accr_number":"AB 661","accr_body":"PCA","test_object":"Bramy z wyłączeniem bram z napędem, Szerokość: do 7000 mm, Wysokość: do 4000 mm","methodology":"Przepuszczalność powietrza","parameters":[{"name":"Zakres","range":"(1,3 - 520) m3/h"}],"technique":null,"techniques":[],"computed":[],"activity":"Przepuszczalność powietrza\nZakres (1,3 - 520) m3/h","reference":"PN-EN 12427:2002 „N”","norm_bases":["PN-EN 12427:2002 „N”"],"lab_section":"Laboratorium Techniki Budowlanej Sp. z o.o.","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Bramy z wyłączeniem bram z napędem, Szerokość: do 7000 mm, Wysokość: do 4000 mm Przepuszczalność powietrza\nZakres (1,3 - 520) m3/h PN-EN 12427:2002 „N” Bramy z wylaczeniem bram z napedem, Szerokosc: do 7000 mm, Wysokosc: do 4000 mm Przepuszczalnosc powietrza\nZakres (1,3 - 520) m3/h PN-EN 12427:2002 „N”","categories":["other"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air permeability","parameters_en":[{"name":"Range","range":"(1,3 - 520) m3/h"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Gates excluding power-operated gates, Width: up to 7000 mm, Height: up to 4000 mm Air permeability „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. Range PN-EN 12427:2002 „N”","test_object_en":"Gates excluding power-operated gates, Width: up to 7000 mm, Height: up to 4000 mm","parameters_zh":[{"name":"范围","range":"(1,3 - 520) m3/h"}],"regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"大门，带驱动装置的大门除外，宽度：至 7000 mm，高度：至 4000 mm 透气性 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 范围 PN-EN 12427:2002 „N”","methodology_zh":"透气性","test_object_zh":"大门，带驱动装置的大门除外，宽度：至 7000 mm，高度：至 4000 mm"},{"_id":"6a837b2faf14b9c0e7b2009c","lab_id":"69ad52a3de79e566650fb360","country":"PL","accr_number":"AB 661","accr_body":"PCA","test_object":"Bramy z wyłączeniem bram z napędem, Szerokość: do 7000 mm, Wysokość: do 4000 mm","methodology":"Odporność na przenikanie wody","parameters":[{"name":"Zakres","range":"(0 - 3600) Pa"}],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na przenikanie wody\nZakres (0 - 3600) Pa","reference":"PN-EN 12489:2002 „N”","norm_bases":["PN-EN 12489:2002 „N”"],"lab_section":"Laboratorium Techniki Budowlanej Sp. z o.o.","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Bramy z wyłączeniem bram z napędem, Szerokość: do 7000 mm, Wysokość: do 4000 mm Odporność na przenikanie wody\nZakres (0 - 3600) Pa PN-EN 12489:2002 „N” Bramy z wylaczeniem bram z napedem, Szerokosc: do 7000 mm, Wysokosc: do 4000 mm Odpornosc na przenikanie wody\nZakres (0 - 3600) Pa PN-EN 12489:2002 „N”","categories":["water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Resistance to water penetration","parameters_en":[{"name":"Range","range":"(0 - 3600) Pa"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Gates excluding power-operated gates, Width: up to 7000 mm, Height: up to 4000 mm Resistance to water penetration „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. Range PN-EN 12489:2002 „N”","test_object_en":"Gates excluding power-operated gates, Width: up to 7000 mm, Height: up to 4000 mm","parameters_zh":[{"name":"范围","range":"(0 - 3600) Pa"}],"regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"大门，带驱动装置的大门除外，宽度：至 7000 mm，高度：至 4000 mm “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 范围 PN-EN 12489:2002 „N”","test_object_zh":"大门，带驱动装置的大门除外，宽度：至 7000 mm，高度：至 4000 mm"},{"_id":"6a837b2faf14b9c0e7b2009d","lab_id":"69ad52a3de79e566650fb360","country":"PL","accr_number":"AB 661","accr_body":"PCA","test_object":"Bramy z wyłączeniem bram z napędem, Szerokość: do 7000 mm, Wysokość: do 4000 mm","methodology":"Odporność na obciążenie wiatrem","parameters":[{"name":"Zakres","range":"(-3600 - +3600) Pa"}],"technique":"Metoda różnicy ciśnień","techniques":["Metoda różnicy ciśnień"],"computed":[],"activity":"Odporność na obciążenie wiatrem\nZakres (-3600 - +3600) Pa\nMetoda różnicy ciśnień","reference":"PN-EN 12444:2002 „N” za wyjątkiem p. 8","norm_bases":["PN-EN 12444:2002 „N” za wyjątkiem p. 8"],"lab_section":"Laboratorium Techniki Budowlanej Sp. z o.o.","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Bramy z wyłączeniem bram z napędem, Szerokość: do 7000 mm, Wysokość: do 4000 mm Odporność na obciążenie wiatrem\nZakres (-3600 - +3600) Pa\nMetoda różnicy ciśnień PN-EN 12444:2002 „N” za wyjątkiem p. 8 Bramy z wylaczeniem bram z napedem, Szerokosc: do 7000 mm, Wysokosc: do 4000 mm Odpornosc na obciazenie wiatrem\nZakres (-3600 - +3600) Pa\nMetoda roznicy cisnien PN-EN 12444:2002 „N” za wyjatkiem p. 8","categories":["other"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Resistance to wind load","parameters_en":[{"name":"Range","range":"(-3600 - +3600) Pa"}],"regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Gates excluding power-operated gates, Width: up to 7000 mm, Height: up to 4000 mm Resistance to wind load Pressure difference method „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. Range PN-EN 12444:2002 „N” za wyjątkiem p. 8","technique_en":"Pressure difference method","test_object_en":"Gates excluding power-operated gates, Width: up to 7000 mm, Height: up to 4000 mm","parameters_zh":[{"name":"范围","range":"(-3600 - +3600) Pa"}],"regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"大门，带驱动装置的大门除外，宽度：至 7000 mm，高度：至 4000 mm 抗风荷载性 压差法 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 范围 PN-EN 12444:2002 „N” za wyjątkiem p. 8","technique_zh":"压差法","methodology_zh":"抗风荷载性","test_object_zh":"大门，带驱动装置的大门除外，宽度：至 7000 mm，高度：至 4000 mm"},{"_id":"6a837b2faf14b9c0e7b2009e","lab_id":"69ad52a3de79e566650fb360","country":"PL","accr_number":"AB 661","accr_body":"PCA","test_object":"Bramy z wyłączeniem bram z napędem, Szerokość: do 7000 mm, Wysokość: do 4000 mm","methodology":"Współczynnik przenikania ciepła","parameters":[],"technique":"Metoda obliczeniowa","techniques":["Metoda obliczeniowa"],"computed":[],"activity":"Współczynnik przenikania ciepła\nMetoda obliczeniowa","reference":"PN-EN 12428:2013-06 „N”","norm_bases":["PN-EN 12428:2013-06 „N”"],"lab_section":"Laboratorium Techniki Budowlanej Sp. z o.o.","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Bramy z wyłączeniem bram z napędem, Szerokość: do 7000 mm, Wysokość: do 4000 mm Współczynnik przenikania ciepła\nMetoda obliczeniowa PN-EN 12428:2013-06 „N” Bramy z wylaczeniem bram z napedem, Szerokosc: do 7000 mm, Wysokosc: do 4000 mm Wspolczynnik przenikania ciepla\nMetoda obliczeniowa PN-EN 12428:2013-06 „N”","categories":["other"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Thermal transmittance","regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Gates excluding power-operated gates, Width: up to 7000 mm, Height: up to 4000 mm Thermal transmittance Calculation method „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. PN-EN 12428:2013-06 „N”","technique_en":"Calculation method","test_object_en":"Gates excluding power-operated gates, Width: up to 7000 mm, Height: up to 4000 mm","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"大门，带驱动装置的大门除外，宽度：至 7000 mm，高度：至 4000 mm 传热系数 计算法 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 PN-EN 12428:2013-06 „N”","technique_zh":"计算法","methodology_zh":"传热系数","test_object_zh":"大门，带驱动装置的大门除外，宽度：至 7000 mm，高度：至 4000 mm"},{"_id":"6a837b2faf14b9c0e7b2009f","lab_id":"69ad52a3de79e566650fb360","country":"PL","accr_number":"AB 661","accr_body":"PCA","test_object":"Ściany osłonowe","methodology":"Współczynnik przenikania ciepła","parameters":[],"technique":"Metoda obliczeniowa","techniques":["Metoda obliczeniowa"],"computed":[],"activity":"Współczynnik przenikania ciepła\nMetoda obliczeniowa","reference":"PN-EN 12631:2017-10 „N” | Procedura PL 121 edycja 10 wydanie z dnia 07.01.2021 r.","norm_bases":["PN-EN 12631:2017-10 „N”","Procedura PL 121 edycja 10 wydanie z dnia 07.01.2021 r."],"lab_section":"Laboratorium Techniki Budowlanej Sp. z o.o.","lab_address":null,"regulatory_area":"„N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r.","flexible":false,"search_text":"Ściany osłonowe Współczynnik przenikania ciepła\nMetoda obliczeniowa PN-EN 12631:2017-10 „N” | Procedura PL 121 edycja 10 wydanie z dnia 07.01.2021 r. Sciany oslonowe Wspolczynnik przenikania ciepla\nMetoda obliczeniowa PN-EN 12631:2017-10 „N” | Procedura PL 121 edycja 10 wydanie z dnia 07.01.2021 r.","categories":["other"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Thermal transmittance","regulatory_area_en":"„N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.","search_en":"Curtain walling Thermal transmittance Calculation method „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. PN-EN 12631:2017-10 „N” | Procedura PL 121 edycja 10 wydanie z dnia 07.01.2021 r.","technique_en":"Calculation method","test_object_en":"Curtain walling","regulatory_area_zh":"“N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。","search_zh":"幕墙 传热系数 计算法 “N” — 依据 2011 年 3 月 9 日欧洲议会和理事会条例（EU）第 305/2011 号，用于通告相关活动的检测方法。 PN-EN 12631:2017-10 „N” | Procedura PL 121 edycja 10 wydanie z dnia 07.01.2021 r.","technique_zh":"计算法","test_object_zh":"幕墙","methodology_zh":"传热系数"},{"_id":"6a837b2faf14b9c0e7b200a0","lab_id":"69ad52a3de79e566650fb360","country":"PL","accr_number":"AB 661","accr_body":"PCA","test_object":"Świetliki dachowe","methodology":"Współczynnik przenikania ciepła.","parameters":[],"technique":"Metoda obliczeniowa","techniques":["Metoda obliczeniowa"],"computed":[],"activity":"Współczynnik przenikania ciepła.\nMetoda obliczeniowa","reference":"PN-EN 1873:2014-07 | Procedura PL 121 edycja 10 wydanie z dnia 07.01.2021 r.","norm_bases":["PN-EN 1873:2014-07","Procedura PL 121 edycja 10 wydanie z dnia 07.01.2021 r."],"lab_section":"Laboratorium Techniki Budowlanej Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Świetliki dachowe Współczynnik przenikania ciepła.\nMetoda obliczeniowa PN-EN 1873:2014-07 | Procedura PL 121 edycja 10 wydanie z dnia 07.01.2021 r. Swietliki dachowe Wspolczynnik przenikania ciepla.\nMetoda obliczeniowa PN-EN 1873:2014-07 | Procedura PL 121 edycja 10 wydanie z dnia 07.01.2021 r.","categories":["construction"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Thermal transmittance.","search_en":"Roof lights Thermal transmittance. Calculation method PN-EN 1873:2014-07 | Procedura PL 121 edycja 10 wydanie z dnia 07.01.2021 r.","technique_en":"Calculation method","test_object_en":"Roof lights","search_zh":"计算法 PN-EN 1873:2014-07 | Procedura PL 121 edycja 10 wydanie z dnia 07.01.2021 r.","technique_zh":"计算法"},{"_id":"6a837b2faf14b9c0e7b200a1","lab_id":"69ad52a3de79e566650fb360","country":"PL","accr_number":"AB 661","accr_body":"PCA","test_object":"Wyrób(y): Drzwi, okna, okiennice, żaluzje, bramy i powiązane z nimi okucia budowlane / Okna (z przymocowanymi okuciami lub bez) / wszystkie inne","methodology":"OCENA WŁAŚCIWOŚCI UŻYTKOWYCH NA PODSTAWIE BADAŃ I OBLICZEŃ, TABELARYCZNYCH WARTOŚCI LUB OPISOWEJ DEOKUMENTACJI WYROBU BUDOWLANEGO (System 3)","parameters":[{"name":"Numer decyzji Komisji","range":"99/93/WE"}],"technique":null,"techniques":[],"computed":[],"activity":"OCENA WŁAŚCIWOŚCI UŻYTKOWYCH NA PODSTAWIE BADAŃ I OBLICZEŃ, TABELARYCZNYCH WARTOŚCI LUB OPISOWEJ DEOKUMENTACJI WYROBU BUDOWLANEGO (System 3)\nNumer decyzji Komisji 99/93/WE","reference":"Zharmonizowane specyfikacje techniczne: EN 14351-1:2006+A2:2016 | Rozporządzenie Parlamentu Europejskiego i Rady (UE) Nr 305/2011 z dnia 9 marca 2011 r. z późniejszymi zmianami, ustanawiające zharmonizowane warunki wprowadzania do obrotu wyrobów budowlanych i uchylające dyrektywę Rady 89/106/EWG (Dz. Urz. UE L 88 z 4.4.2011, z późn. zm.)","norm_bases":["Zharmonizowane specyfikacje techniczne: EN 14351-1:2006+A2:2016","Rozporządzenie Parlamentu Europejskiego i Rady (UE) Nr 305/2011 z dnia 9 marca 2011 r. z późniejszymi zmianami, ustanawiające zharmonizowane warunki wprowadzania do obrotu wyrobów budowlanych i uchylające dyrektywę Rady 89/106/EWG (Dz. Urz. UE L 88 z 4.4.2011, z późn. zm.)"],"lab_section":"Laboratorium Techniki Budowlanej Sp. z o.o.","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 99/93/WE; 96/580/WE. Laboratorium spełnia wymagania określone w Rozporządzeniu Nr 305/2011 z dnia 9 marca 2011 r. w zakresie prowadzonej działalności przewidzianej dla laboratorium badawczego (Załącznik V, pkt 2, ppkt. 3 Rozporządzenia Nr 305/2011) w powyższym zakresie.","flexible":false,"search_text":"Wyrób(y): Drzwi, okna, okiennice, żaluzje, bramy i powiązane z nimi okucia budowlane / Okna (z przymocowanymi okuciami lub bez) / wszystkie inne OCENA WŁAŚCIWOŚCI UŻYTKOWYCH NA PODSTAWIE BADAŃ I OBLICZEŃ, TABELARYCZNYCH WARTOŚCI LUB OPISOWEJ DEOKUMENTACJI WYROBU BUDOWLANEGO (System 3)\nNumer decyzji Komisji 99/93/WE Zharmonizowane specyfikacje techniczne: EN 14351-1:2006+A2:2016 | Rozporządzenie Parlamentu Europejskiego i Rady (UE) Nr 305/2011 z dnia 9 marca 2011 r. z późniejszymi zmianami, ustanawiające zharmonizowane warunki wprowadzania do obrotu wyrobów budowlanych i uchylające dyrektywę Rady 89/106/EWG (Dz. Urz. UE L 88 z 4.4.2011, z późn. zm.) Wyrob(y): Drzwi, okna, okiennice, zaluzje, bramy i powiazane z nimi okucia budowlane / Okna (z przymocowanymi okuciami lub bez) / wszystkie inne OCENA WLASCIWOSCI UZYTKOWYCH NA PODSTAWIE BADAN I OBLICZEN, TABELARYCZNYCH WARTOSCI LUB OPISOWEJ DEOKUMENTACJI WYROBU BUDOWLANEGO (System 3)\nNumer decyzji Komisji 99/93/WE Zharmonizowane specyfikacje techniczne: EN 14351-1:2006+A2:2016 | Rozporzadzenie Parlamentu Europejskiego i Rady (UE) Nr 305/2011 z dnia 9 marca 2011 r. z pozniejszymi zmianami, ustanawiajace zharmonizowane warunki wprowadzania do obrotu wyrobow budowlanych i uchylajace dyrektywe Rady 89/106/EWG (Dz. Urz. UE L 88 z 4.4.2011, z pozn. zm.)","categories":["construction"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Commission decision number","range":"99/93/WE"}],"search_en":"Commission decision number Zharmonizowane specyfikacje techniczne: EN 14351-1:2006+A2:2016 | Rozporządzenie Parlamentu Europejskiego i Rady (UE) Nr 305/2011 z dnia 9 marca 2011 r. z późniejszymi zmianami, ustanawiające zharmonizowane warunki wprowadzania do obrotu wyrobów budowlanych i uchylające dyrektywę Rady 89/106/EWG (Dz. Urz. UE L 88 z 4.4.2011, z późn. zm.)","parameters_zh":[{"name":"委员会决定编号","range":"99/93/WE"}],"search_zh":"委员会决定编号 Zharmonizowane specyfikacje techniczne: EN 14351-1:2006+A2:2016 | Rozporządzenie Parlamentu Europejskiego i Rady (UE) Nr 305/2011 z dnia 9 marca 2011 r. z późniejszymi zmianami, ustanawiające zharmonizowane warunki wprowadzania do obrotu wyrobów budowlanych i uchylające dyrektywę Rady 89/106/EWG (Dz. Urz. UE L 88 z 4.4.2011, z późn. zm.)"},{"_id":"6a837b2faf14b9c0e7b200a2","lab_id":"69ad52a3de79e566650fb360","country":"PL","accr_number":"AB 661","accr_body":"PCA","test_object":"Wyrób(y): Drzwi, okna, okiennice, żaluzje, bramy i powiązane z nimi okucia budowlane / Drzwi i bramy (z przymocowanymi okuciami lub bez) / inne wymienione specyficzne zastosowania lub zastosowania podlegające innym specyficznym wymaganiom, w szczególności takim jak hałas, energia, szczelność i bezpieczeństwo użytkowania","methodology":"OCENA WŁAŚCIWOŚCI UŻYTKOWYCH NA PODSTAWIE BADAŃ I OBLICZEŃ, TABELARYCZNYCH WARTOŚCI LUB OPISOWEJ DEOKUMENTACJI WYROBU BUDOWLANEGO (System 3)","parameters":[{"name":"Numer decyzji Komisji","range":"99/93/WE"}],"technique":null,"techniques":[],"computed":[],"activity":"OCENA WŁAŚCIWOŚCI UŻYTKOWYCH NA PODSTAWIE BADAŃ I OBLICZEŃ, TABELARYCZNYCH WARTOŚCI LUB OPISOWEJ DEOKUMENTACJI WYROBU BUDOWLANEGO (System 3)\nNumer decyzji Komisji 99/93/WE","reference":"Zharmonizowane specyfikacje techniczne: EN 13241:2003+A2:2016 | Rozporządzenie Parlamentu Europejskiego i Rady (UE) Nr 305/2011 z dnia 9 marca 2011 r. z późniejszymi zmianami, ustanawiające zharmonizowane warunki wprowadzania do obrotu wyrobów budowlanych i uchylające dyrektywę Rady 89/106/EWG (Dz. Urz. UE L 88 z 4.4.2011, z późn. zm.)","norm_bases":["Zharmonizowane specyfikacje techniczne: EN 13241:2003+A2:2016","Rozporządzenie Parlamentu Europejskiego i Rady (UE) Nr 305/2011 z dnia 9 marca 2011 r. z późniejszymi zmianami, ustanawiające zharmonizowane warunki wprowadzania do obrotu wyrobów budowlanych i uchylające dyrektywę Rady 89/106/EWG (Dz. Urz. UE L 88 z 4.4.2011, z późn. zm.)"],"lab_section":"Laboratorium Techniki Budowlanej Sp. z o.o.","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 99/93/WE; 96/580/WE. Laboratorium spełnia wymagania określone w Rozporządzeniu Nr 305/2011 z dnia 9 marca 2011 r. w zakresie prowadzonej działalności przewidzianej dla laboratorium badawczego (Załącznik V, pkt 2, ppkt. 3 Rozporządzenia Nr 305/2011) w powyższym zakresie.","flexible":false,"search_text":"Wyrób(y): Drzwi, okna, okiennice, żaluzje, bramy i powiązane z nimi okucia budowlane / Drzwi i bramy (z przymocowanymi okuciami lub bez) / inne wymienione specyficzne zastosowania lub zastosowania podlegające innym specyficznym wymaganiom, w szczególności takim jak hałas, energia, szczelność i bezpieczeństwo użytkowania OCENA WŁAŚCIWOŚCI UŻYTKOWYCH NA PODSTAWIE BADAŃ I OBLICZEŃ, TABELARYCZNYCH WARTOŚCI LUB OPISOWEJ DEOKUMENTACJI WYROBU BUDOWLANEGO (System 3)\nNumer decyzji Komisji 99/93/WE Zharmonizowane specyfikacje techniczne: EN 13241:2003+A2:2016 | Rozporządzenie Parlamentu Europejskiego i Rady (UE) Nr 305/2011 z dnia 9 marca 2011 r. z późniejszymi zmianami, ustanawiające zharmonizowane warunki wprowadzania do obrotu wyrobów budowlanych i uchylające dyrektywę Rady 89/106/EWG (Dz. Urz. UE L 88 z 4.4.2011, z późn. zm.) Wyrob(y): Drzwi, okna, okiennice, zaluzje, bramy i powiazane z nimi okucia budowlane / Drzwi i bramy (z przymocowanymi okuciami lub bez) / inne wymienione specyficzne zastosowania lub zastosowania podlegajace innym specyficznym wymaganiom, w szczegolnosci takim jak halas, energia, szczelnosc i bezpieczenstwo uzytkowania OCENA WLASCIWOSCI UZYTKOWYCH NA PODSTAWIE BADAN I OBLICZEN, TABELARYCZNYCH WARTOSCI LUB OPISOWEJ DEOKUMENTACJI WYROBU BUDOWLANEGO (System 3)\nNumer decyzji Komisji 99/93/WE Zharmonizowane specyfikacje techniczne: EN 13241:2003+A2:2016 | Rozporzadzenie Parlamentu Europejskiego i Rady (UE) Nr 305/2011 z dnia 9 marca 2011 r. z pozniejszymi zmianami, ustanawiajace zharmonizowane warunki wprowadzania do obrotu wyrobow budowlanych i uchylajace dyrektywe Rady 89/106/EWG (Dz. Urz. UE L 88 z 4.4.2011, z pozn. zm.)","categories":["environment","construction"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Commission decision number","range":"99/93/WE"}],"search_en":"Commission decision number Zharmonizowane specyfikacje techniczne: EN 13241:2003+A2:2016 | Rozporządzenie Parlamentu Europejskiego i Rady (UE) Nr 305/2011 z dnia 9 marca 2011 r. z późniejszymi zmianami, ustanawiające zharmonizowane warunki wprowadzania do obrotu wyrobów budowlanych i uchylające dyrektywę Rady 89/106/EWG (Dz. Urz. UE L 88 z 4.4.2011, z późn. zm.)","parameters_zh":[{"name":"委员会决定编号","range":"99/93/WE"}],"search_zh":"委员会决定编号 Zharmonizowane specyfikacje techniczne: EN 13241:2003+A2:2016 | Rozporządzenie Parlamentu Europejskiego i Rady (UE) Nr 305/2011 z dnia 9 marca 2011 r. z późniejszymi zmianami, ustanawiające zharmonizowane warunki wprowadzania do obrotu wyrobów budowlanych i uchylające dyrektywę Rady 89/106/EWG (Dz. Urz. UE L 88 z 4.4.2011, z późn. zm.)"},{"_id":"6a837b2faf14b9c0e7b200a3","lab_id":"69ad52a3de79e566650fb360","country":"PL","accr_number":"AB 661","accr_body":"PCA","test_object":"Wyrób(y): Zestawy ścian osłonowych / jako zewnętrzne ściany osłonowe nie objęte wymaganiami w zakresie reakcji na ogień","methodology":"OCENA WŁAŚCIWOŚCI UŻYTKOWYCH NA PODSTAWIE BADAŃ I OBLICZEŃ, TABELARYCZNYCH WARTOŚCI LUB OPISOWEJ DEOKUMENTACJI WYROBU BUDOWLANEGO (System 3)","parameters":[{"name":"Numer decyzji Komisji","range":"96/580/WE"}],"technique":null,"techniques":[],"computed":[],"activity":"OCENA WŁAŚCIWOŚCI UŻYTKOWYCH NA PODSTAWIE BADAŃ I OBLICZEŃ, TABELARYCZNYCH WARTOŚCI LUB OPISOWEJ DEOKUMENTACJI WYROBU BUDOWLANEGO (System 3)\nNumer decyzji Komisji 96/580/WE","reference":"Zharmonizowane specyfikacje techniczne: EN 13830:2003 | Rozporządzenie Parlamentu Europejskiego i Rady (UE) Nr 305/2011 z dnia 9 marca 2011 r. z późniejszymi zmianami, ustanawiające zharmonizowane warunki wprowadzania do obrotu wyrobów budowlanych i uchylające dyrektywę Rady 89/106/EWG (Dz. Urz. UE L 88 z 4.4.2011, z późn. zm.)","norm_bases":["Zharmonizowane specyfikacje techniczne: EN 13830:2003","Rozporządzenie Parlamentu Europejskiego i Rady (UE) Nr 305/2011 z dnia 9 marca 2011 r. z późniejszymi zmianami, ustanawiające zharmonizowane warunki wprowadzania do obrotu wyrobów budowlanych i uchylające dyrektywę Rady 89/106/EWG (Dz. Urz. UE L 88 z 4.4.2011, z późn. zm.)"],"lab_section":"Laboratorium Techniki Budowlanej Sp. z o.o.","lab_address":null,"regulatory_area":"Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 99/93/WE; 96/580/WE. Laboratorium spełnia wymagania określone w Rozporządzeniu Nr 305/2011 z dnia 9 marca 2011 r. w zakresie prowadzonej działalności przewidzianej dla laboratorium badawczego (Załącznik V, pkt 2, ppkt. 3 Rozporządzenia Nr 305/2011) w powyższym zakresie.","flexible":false,"search_text":"Wyrób(y): Zestawy ścian osłonowych / jako zewnętrzne ściany osłonowe nie objęte wymaganiami w zakresie reakcji na ogień OCENA WŁAŚCIWOŚCI UŻYTKOWYCH NA PODSTAWIE BADAŃ I OBLICZEŃ, TABELARYCZNYCH WARTOŚCI LUB OPISOWEJ DEOKUMENTACJI WYROBU BUDOWLANEGO (System 3)\nNumer decyzji Komisji 96/580/WE Zharmonizowane specyfikacje techniczne: EN 13830:2003 | Rozporządzenie Parlamentu Europejskiego i Rady (UE) Nr 305/2011 z dnia 9 marca 2011 r. z późniejszymi zmianami, ustanawiające zharmonizowane warunki wprowadzania do obrotu wyrobów budowlanych i uchylające dyrektywę Rady 89/106/EWG (Dz. Urz. UE L 88 z 4.4.2011, z późn. zm.) Wyrob(y): Zestawy scian oslonowych / jako zewnetrzne sciany oslonowe nie objete wymaganiami w zakresie reakcji na ogien OCENA WLASCIWOSCI UZYTKOWYCH NA PODSTAWIE BADAN I OBLICZEN, TABELARYCZNYCH WARTOSCI LUB OPISOWEJ DEOKUMENTACJI WYROBU BUDOWLANEGO (System 3)\nNumer decyzji Komisji 96/580/WE Zharmonizowane specyfikacje techniczne: EN 13830:2003 | Rozporzadzenie Parlamentu Europejskiego i Rady (UE) Nr 305/2011 z dnia 9 marca 2011 r. z pozniejszymi zmianami, ustanawiajace zharmonizowane warunki wprowadzania do obrotu wyrobow budowlanych i uchylajace dyrektywe Rady 89/106/EWG (Dz. Urz. UE L 88 z 4.4.2011, z pozn. zm.)","categories":["construction"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Commission decision number","range":"96/580/WE"}],"search_en":"Commission decision number Zharmonizowane specyfikacje techniczne: EN 13830:2003 | Rozporządzenie Parlamentu Europejskiego i Rady (UE) Nr 305/2011 z dnia 9 marca 2011 r. z późniejszymi zmianami, ustanawiające zharmonizowane warunki wprowadzania do obrotu wyrobów budowlanych i uchylające dyrektywę Rady 89/106/EWG (Dz. Urz. UE L 88 z 4.4.2011, z późn. zm.)","parameters_zh":[{"name":"委员会决定编号","range":"96/580/WE"}],"search_zh":"委员会决定编号 Zharmonizowane specyfikacje techniczne: EN 13830:2003 | Rozporządzenie Parlamentu Europejskiego i Rady (UE) Nr 305/2011 z dnia 9 marca 2011 r. z późniejszymi zmianami, ustanawiające zharmonizowane warunki wprowadzania do obrotu wyrobów budowlanych i uchylające dyrektywę Rady 89/106/EWG (Dz. Urz. UE L 88 z 4.4.2011, z późn. zm.)"}],"has_pdf":true}