{"lab":{"_id":"69ad52a3de79e566650fb34e","accr_number":"AB 646","country":"PL","accr_body":"PCA","address":"INSTYTUT MORSKI, ul. Morska 81-87, 81-225 Gdynia, LABORATORIUM ZAKŁADU OCHRONY ŚRODOWISKA, ul. Trzy Lipy 3","categories":["water","environment","construction","petro","materials"],"city":"Gdynia","imported_at":"2026-03-08T10:42:43.265Z","methods_count":138,"name":"UNIWERSYTET MORSKI W GDYNI","parse_status":"parsed","parse_version":3,"pdf_files":["AB_646.pdf"],"scope_summary":"","search_text":"uniwersytet morski w gdyni instytut morski, ul. morska 81-87, 81-225 gdynia, laboratorium zakładu ochrony środowiska, ul. trzy lipy 3 water other environment metrology petro food pharma electronics construction materials","status":"active","updated_at":"2026-03-08T14:51:33.091Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-17T21:12:50.434Z","location":{"type":"Point","coordinates":[18.5305,54.5189]},"email_confidence":"high","email_mx":true,"email_source":"https://www.pca.gov.pl/akredytowane-podmioty/akredytacje-aktywne/laboratoria-badawcze/AB%20646,podmiot.html","fields_of_testing":[{"codes":"C/28/P, C/29/P, C/30/P, C/31/P, C/32/P","pl":"Badania chemiczne i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków, gruntów, osadów, odpadów","en":"Chemical tests and sampling of water, drinking water, sewage, soil, sediments, waste"},{"codes":"C/3; C/22","pl":"Badania chemiczne obiektów i materiałów biologicznych przeznaczonych do badań, żywności","en":"Chemical tests of biological items and materials for testing, food"},{"codes":"N/28/P, N/29/P, N/30/P, N/31/P, N/32/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków, gruntów, osadów, odpadów","en":"Tests of physical properties and sampling water, drinking water, sewage, soil, sediments, waste"}],"issue":{"no":"26","date":"29.06.2026"},"parse_date":"2026-08-17T21:12:50.434Z","parse_source":"agent-claude-code","map_coord":[54.526437,18.511657],"map_geo":"nominatim-street","lab_locations":[{"name":"LABORATORIUM ZAKŁADU OCHRONY ŚRODOWISKA","address":"ul. Trzy Lipy 3","city":"Gdańsk","postal":"80-172"}],"scope_format":"PCA::pracownie+siatka5","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/a133b567da952decb0a0db36fa3aa700/AB%20646.pdf","has_en":true,"category_counts":{"water":128,"environment":31,"construction":16,"petro":5,"materials":5,"other":2},"category_scores":{"water":87.61,"environment":5.14,"construction":1.37,"petro":0.13,"materials":0.13,"other":0.02},"has_zh":true},"methods":[{"_id":"6a837952af14b9c0e7b1fc36","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda podziemna","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura","parameters":[{"name":"Zakres","range":"(0 – 50)°C"}],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura\nZakres (0 – 50)°C","reference":"I-25 wydanie 2 z dnia 26.02.2024 r. | I-29 wydanie 2 z dnia 26.02.2024 r.","norm_bases":["I-25 wydanie 2 z dnia 26.02.2024 r.","I-29 wydanie 2 z dnia 26.02.2024 r."],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda podziemna Pobieranie próbek do badań chemicznych i fizycznych Temperatura\nZakres (0 – 50)°C I-25 wydanie 2 z dnia 26.02.2024 r. | I-29 wydanie 2 z dnia 26.02.2024 r. Woda podziemna Pobieranie probek do badan chemicznych i fizycznych Temperatura\nZakres (0 – 50)°C I-25 wydanie 2 z dnia 26.02.2024 r. | I-29 wydanie 2 z dnia 26.02.2024 r.","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing Temperature","parameters_en":[{"name":"Range","range":"(0 – 50)°C"}],"search_en":"Groundwater Sampling for chemical and physical testing Temperature Range I-25 wydanie 2 z dnia 26.02.2024 r. | I-29 wydanie 2 z dnia 26.02.2024 r.","test_object_en":"Groundwater","parameters_zh":[{"name":"范围","range":"(0 – 50)°C"}],"search_zh":"地下水 化学和物理检测采样 温度 范围 I-25 wydanie 2 z dnia 26.02.2024 r. | I-29 wydanie 2 z dnia 26.02.2024 r.","methodology_zh":"化学和物理检测采样 温度","test_object_zh":"地下水"},{"_id":"6a837952af14b9c0e7b1fc37","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Ścieki, Wody opadowe i roztopowe","methodology":"Pobieranie próbek do badań fizycznych i chemicznych","parameters":[{"name":"Temperatura"},{"name":"Zakres","range":"(-4 – 50) °C"}],"technique":"Metoda manualna","techniques":["Metoda manualna"],"computed":[],"activity":"Pobieranie próbek do badań fizycznych i chemicznych\nZakres:\nTemperatura\nZakres (-4 – 50) °C\nMetoda manualna","reference":"PN-ISO 5667-10:2021-11 | I-29 wydanie 2 z dnia 26.02.2024 r.","norm_bases":["PN-ISO 5667-10:2021-11","I-29 wydanie 2 z dnia 26.02.2024 r."],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, Wody opadowe i roztopowe Pobieranie próbek do badań fizycznych i chemicznych\nZakres:\nTemperatura\nZakres (-4 – 50) °C\nMetoda manualna PN-ISO 5667-10:2021-11 | I-29 wydanie 2 z dnia 26.02.2024 r. Scieki, Wody opadowe i roztopowe Pobieranie probek do badan fizycznych i chemicznych\nZakres:\nTemperatura\nZakres (-4 – 50) °C\nMetoda manualna PN-ISO 5667-10:2021-11 | I-29 wydanie 2 z dnia 26.02.2024 r.","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for physical and chemical testing","parameters_en":[{"name":"Temperature"},{"name":"Range","range":"(-4 – 50) °C"}],"search_en":"Wastewater, Rainwater and snowmelt water Sampling for physical and chemical testing Manual method Temperature Range PN-ISO 5667-10:2021-11 | I-29 wydanie 2 z dnia 26.02.2024 r.","technique_en":"Manual method","test_object_en":"Wastewater, Rainwater and snowmelt water","methodology_zh":"物理与化学检测用样品采集","parameters_zh":[{"name":"温度"},{"name":"范围","range":"(-4 – 50) °C"}],"search_zh":"废水、雨水与融雪水 物理与化学检测用样品采集 手工法 温度 范围 PN-ISO 5667-10:2021-11 | I-29 wydanie 2 z dnia 26.02.2024 r.","technique_zh":"手工法","test_object_zh":"废水、雨水与融雪水"},{"_id":"6a837952af14b9c0e7b1fc38","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań fizycznych i chemicznych Temperatura","parameters":[{"name":"Zakres","range":"(0 – 50) oC"}],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań fizycznych i chemicznych Temperatura\nZakres (0 – 50) oC","reference":"PN-ISO 5667-5:2017-10 | I-29 wydanie 2 z dnia 26.02.2024 r.","norm_bases":["PN-ISO 5667-5:2017-10","I-29 wydanie 2 z dnia 26.02.2024 r."],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań fizycznych i chemicznych Temperatura\nZakres (0 – 50) oC PN-ISO 5667-5:2017-10 | I-29 wydanie 2 z dnia 26.02.2024 r. Woda do spozycia przez ludzi Pobieranie probek do badan fizycznych i chemicznych Temperatura\nZakres (0 – 50) oC PN-ISO 5667-5:2017-10 | I-29 wydanie 2 z dnia 26.02.2024 r.","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0 – 50) oC"}],"search_en":"Water intended for human consumption Range PN-ISO 5667-5:2017-10 | I-29 wydanie 2 z dnia 26.02.2024 r.","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0 – 50) oC"}],"search_zh":"生活饮用水 范围 PN-ISO 5667-5:2017-10 | I-29 wydanie 2 z dnia 26.02.2024 r.","test_object_zh":"生活饮用水"},{"_id":"6a837952af14b9c0e7b1fc39","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda powierzchniowa","methodology":"Pobieranie próbek do badań fizycznych i chemicznych Temperatura","parameters":[{"name":"Zakres","range":"(0 – 35) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań fizycznych i chemicznych Temperatura\nZakres (0 – 35) °C","reference":"PN-ISO 5667-6:2016-12 | PN-ISO 5667-4:2017-10 | I-29 wydanie 2 z dnia 26.02.2024 r.","norm_bases":["PN-ISO 5667-6:2016-12","PN-ISO 5667-4:2017-10","I-29 wydanie 2 z dnia 26.02.2024 r."],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda powierzchniowa Pobieranie próbek do badań fizycznych i chemicznych Temperatura\nZakres (0 – 35) °C PN-ISO 5667-6:2016-12 | PN-ISO 5667-4:2017-10 | I-29 wydanie 2 z dnia 26.02.2024 r. Woda powierzchniowa Pobieranie probek do badan fizycznych i chemicznych Temperatura\nZakres (0 – 35) °C PN-ISO 5667-6:2016-12 | PN-ISO 5667-4:2017-10 | I-29 wydanie 2 z dnia 26.02.2024 r.","categories":["water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0 – 35) °C"}],"search_en":"Surface water Range PN-ISO 5667-6:2016-12 | PN-ISO 5667-4:2017-10 | I-29 wydanie 2 z dnia 26.02.2024 r.","test_object_en":"Surface water","parameters_zh":[{"name":"范围","range":"(0 – 35) °C"}],"search_zh":"地表水 范围 PN-ISO 5667-6:2016-12 | PN-ISO 5667-4:2017-10 | I-29 wydanie 2 z dnia 26.02.2024 r.","test_object_zh":"地表水"},{"_id":"6a837952af14b9c0e7b1fc3a","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda morska","methodology":"Pobieranie próbek do badań fizycznych i chemicznych Temperatura","parameters":[{"name":"Zakres","range":"(-4 – 35) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań fizycznych i chemicznych Temperatura\nZakres (-4 – 35) °C","reference":"PN-ISO 5667-9:2005 | I-29 wydanie 2 z dnia 26.02.2024 r.","norm_bases":["PN-ISO 5667-9:2005","I-29 wydanie 2 z dnia 26.02.2024 r."],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda morska Pobieranie próbek do badań fizycznych i chemicznych Temperatura\nZakres (-4 – 35) °C PN-ISO 5667-9:2005 | I-29 wydanie 2 z dnia 26.02.2024 r. Woda morska Pobieranie probek do badan fizycznych i chemicznych Temperatura\nZakres (-4 – 35) °C PN-ISO 5667-9:2005 | I-29 wydanie 2 z dnia 26.02.2024 r.","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(-4 – 35) °C"}],"search_en":"Seawater Range PN-ISO 5667-9:2005 | I-29 wydanie 2 z dnia 26.02.2024 r.","test_object_en":"Seawater","parameters_zh":[{"name":"范围","range":"(-4 – 35) °C"}],"search_zh":"海水 范围 PN-ISO 5667-9:2005 | I-29 wydanie 2 z dnia 26.02.2024 r.","test_object_zh":"海水"},{"_id":"6a837952af14b9c0e7b1fc3b","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Pobieranie próbek do badań fizycznych i chemicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań fizycznych i chemicznych","reference":"PN-EN ISO 5667-13:2011 z wyłączeniem punktów 6.3.3; 6.3.4; 6.3.5; 6.3.7; 6.3.8.5","norm_bases":["PN-EN ISO 5667-13:2011 z wyłączeniem punktów 6.3.3; 6.3.4; 6.3.5; 6.3.7; 6.3.8.5"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Pobieranie próbek do badań fizycznych i chemicznych PN-EN ISO 5667-13:2011 z wyłączeniem punktów 6.3.3; 6.3.4; 6.3.5; 6.3.7; 6.3.8.5 Osady sciekowe Pobieranie probek do badan fizycznych i chemicznych PN-EN ISO 5667-13:2011 z wylaczeniem punktow 6.3.3; 6.3.4; 6.3.5; 6.3.7; 6.3.8.5","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for physical and chemical testing","search_en":"Sewage sludge Sampling for physical and chemical testing PN-EN ISO 5667-13:2011 z wyłączeniem punktów 6.3.3; 6.3.4; 6.3.5; 6.3.7; 6.3.8.5","test_object_en":"Sewage sludge","methodology_zh":"物理与化学检测用样品采集","search_zh":"污泥 物理与化学检测用样品采集 PN-EN ISO 5667-13:2011 z wyłączeniem punktów 6.3.3; 6.3.4; 6.3.5; 6.3.7; 6.3.8.5","test_object_zh":"污泥"},{"_id":"6a837952af14b9c0e7b1fc3c","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Gleba, Grunty","methodology":"Pobieranie próbek do badań fizycznych i chemicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań fizycznych i chemicznych","reference":"PN-R-04031:1997 | PN-ISO 10381-4:2007-01 | PN-ISO 10381-5:2009","norm_bases":["PN-R-04031:1997","PN-ISO 10381-4:2007-01","PN-ISO 10381-5:2009"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, Grunty Pobieranie próbek do badań fizycznych i chemicznych PN-R-04031:1997 | PN-ISO 10381-4:2007-01 | PN-ISO 10381-5:2009 Gleba, Grunty Pobieranie probek do badan fizycznych i chemicznych PN-R-04031:1997 | PN-ISO 10381-4:2007-01 | PN-ISO 10381-5:2009","categories":["environment"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for physical and chemical testing","search_en":"Soil, Grounds Sampling for physical and chemical testing PN-R-04031:1997 | PN-ISO 10381-4:2007-01 | PN-ISO 10381-5:2009","test_object_en":"Soil, Grounds","methodology_zh":"物理与化学检测用样品采集","search_zh":"物理与化学检测用样品采集 PN-R-04031:1997 | PN-ISO 10381-4:2007-01 | PN-ISO 10381-5:2009"},{"_id":"6a837952af14b9c0e7b1fc3d","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Osady denne","methodology":"Pobieranie próbek do badań fizycznych i chemicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań fizycznych i chemicznych","reference":"PN-EN ISO 5667-19:2006","norm_bases":["PN-EN ISO 5667-19:2006"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady denne Pobieranie próbek do badań fizycznych i chemicznych PN-EN ISO 5667-19:2006 Osady denne Pobieranie probek do badan fizycznych i chemicznych PN-EN ISO 5667-19:2006","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for physical and chemical testing","search_en":"Bottom sediments Sampling for physical and chemical testing PN-EN ISO 5667-19:2006","test_object_en":"Bottom sediments","methodology_zh":"物理与化学检测用样品采集","search_zh":"底泥 物理与化学检测用样品采集 PN-EN ISO 5667-19:2006","test_object_zh":"底泥"},{"_id":"6a837952af14b9c0e7b1fc3e","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda morska","methodology":"Stężenie azotu ogólnego","parameters":[{"name":"Zakres","range":"(5,0 – 60) μmol/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu ogólnego\nZakres (5,0 – 60) μmol/dm3\nMetoda spektrofotometryczna","reference":"PB–27 wydanie 5 z dnia 22.02.2024 r.","norm_bases":["PB–27 wydanie 5 z dnia 22.02.2024 r."],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda morska Stężenie azotu ogólnego\nZakres (5,0 – 60) μmol/dm3\nMetoda spektrofotometryczna PB–27 wydanie 5 z dnia 22.02.2024 r. Woda morska Stezenie azotu ogolnego\nZakres (5,0 – 60) μmol/dm3\nMetoda spektrofotometryczna PB–27 wydanie 5 z dnia 22.02.2024 r.","categories":["water"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total nitrogen concentration","parameters_en":[{"name":"Range","range":"(5,0 – 60) μmol/dm3"}],"search_en":"Seawater Total nitrogen concentration Spectrophotometric method Range PB–27 wydanie 5 z dnia 22.02.2024 r.","technique_en":"Spectrophotometric method","test_object_en":"Seawater","methodology_zh":"总氮浓度","parameters_zh":[{"name":"范围","range":"(5,0 – 60) μmol/dm3"}],"search_zh":"海水 总氮浓度 分光光度法 范围 PB–27 wydanie 5 z dnia 22.02.2024 r.","technique_zh":"分光光度法","test_object_zh":"海水"},{"_id":"6a837952af14b9c0e7b1fc3f","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda morska","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,20 – 15) μmol/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,20 – 15) μmol/dm3\nMetoda spektrofotometryczna","reference":"PB–30 wydanie 6 z dnia 22.02.2024 r.","norm_bases":["PB–30 wydanie 6 z dnia 22.02.2024 r."],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda morska Stężenie azotu amonowego\nZakres (0,20 – 15) μmol/dm3\nMetoda spektrofotometryczna PB–30 wydanie 6 z dnia 22.02.2024 r. Woda morska Stezenie azotu amonowego\nZakres (0,20 – 15) μmol/dm3\nMetoda spektrofotometryczna PB–30 wydanie 6 z dnia 22.02.2024 r.","categories":["water"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,20 – 15) μmol/dm3"}],"search_en":"Seawater Ammonium nitrogen concentration Spectrophotometric method Range PB–30 wydanie 6 z dnia 22.02.2024 r.","technique_en":"Spectrophotometric method","test_object_en":"Seawater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,20 – 15) μmol/dm3"}],"search_zh":"海水 氨氮浓度 分光光度法 范围 PB–30 wydanie 6 z dnia 22.02.2024 r.","technique_zh":"分光光度法","test_object_zh":"海水"},{"_id":"6a837952af14b9c0e7b1fc40","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda morska","methodology":"Stężenie azotu azotanowego","parameters":[{"name":"Zakres","range":"(0,20 – 15) μmol/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotanowego\nZakres (0,20 – 15) μmol/dm3\nMetoda spektrofotometryczna","reference":"PB–28 wydanie 7 z dnia 22.02.2024 r.","norm_bases":["PB–28 wydanie 7 z dnia 22.02.2024 r."],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda morska Stężenie azotu azotanowego\nZakres (0,20 – 15) μmol/dm3\nMetoda spektrofotometryczna PB–28 wydanie 7 z dnia 22.02.2024 r. Woda morska Stezenie azotu azotanowego\nZakres (0,20 – 15) μmol/dm3\nMetoda spektrofotometryczna PB–28 wydanie 7 z dnia 22.02.2024 r.","categories":["water"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,20 – 15) μmol/dm3"}],"search_en":"Seawater Nitrate nitrogen concentration Spectrophotometric method Range PB–28 wydanie 7 z dnia 22.02.2024 r.","technique_en":"Spectrophotometric method","test_object_en":"Seawater","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,20 – 15) μmol/dm3"}],"search_zh":"海水 硝态氮浓度 分光光度法 范围 PB–28 wydanie 7 z dnia 22.02.2024 r.","technique_zh":"分光光度法","test_object_zh":"海水"},{"_id":"6a837952af14b9c0e7b1fc41","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda morska","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,20 – 3,0) μmol/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres (0,20 – 3,0) μmol/dm3\nMetoda spektrofotometryczna","reference":"PB–29 wydanie 7 z dnia 22.02.2024 r.","norm_bases":["PB–29 wydanie 7 z dnia 22.02.2024 r."],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda morska Stężenie azotu azotynowego\nZakres (0,20 – 3,0) μmol/dm3\nMetoda spektrofotometryczna PB–29 wydanie 7 z dnia 22.02.2024 r. Woda morska Stezenie azotu azotynowego\nZakres (0,20 – 3,0) μmol/dm3\nMetoda spektrofotometryczna PB–29 wydanie 7 z dnia 22.02.2024 r.","categories":["water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,20 – 3,0) μmol/dm3"}],"search_en":"Seawater Nitrite nitrogen concentration Spectrophotometric method Range PB–29 wydanie 7 z dnia 22.02.2024 r.","technique_en":"Spectrophotometric method","test_object_en":"Seawater","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,20 – 3,0) μmol/dm3"}],"search_zh":"海水 亚硝态氮浓度 分光光度法 范围 PB–29 wydanie 7 z dnia 22.02.2024 r.","technique_zh":"分光光度法","test_object_zh":"海水"},{"_id":"6a837952af14b9c0e7b1fc42","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda morska","methodology":"Stężenie azotu mineralnego (DIN) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu mineralnego (DIN) (z obliczeń)","reference":"I-16 wydanie 3 z dnia 26.02.2024 r.","norm_bases":["I-16 wydanie 3 z dnia 26.02.2024 r."],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda morska Stężenie azotu mineralnego (DIN) (z obliczeń) I-16 wydanie 3 z dnia 26.02.2024 r. Woda morska Stezenie azotu mineralnego (DIN) (z obliczen) I-16 wydanie 3 z dnia 26.02.2024 r.","categories":["water"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mineral nitrogen (DIN) concentration (calculated)","search_en":"Seawater Mineral nitrogen (DIN) concentration (calculated) I-16 wydanie 3 z dnia 26.02.2024 r.","test_object_en":"Seawater","search_zh":"海水 I-16 wydanie 3 z dnia 26.02.2024 r.","test_object_zh":"海水"},{"_id":"6a837952af14b9c0e7b1fc43","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda morska","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,30 – 10) μmol/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,30 – 10) μmol/dm3\nMetoda spektrofotometryczna","reference":"PB–31 wydanie 7 z dnia 22.02.2024 r.","norm_bases":["PB–31 wydanie 7 z dnia 22.02.2024 r."],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda morska Stężenie fosforu ogólnego\nZakres (0,30 – 10) μmol/dm3\nMetoda spektrofotometryczna PB–31 wydanie 7 z dnia 22.02.2024 r. Woda morska Stezenie fosforu ogolnego\nZakres (0,30 – 10) μmol/dm3\nMetoda spektrofotometryczna PB–31 wydanie 7 z dnia 22.02.2024 r.","categories":["water"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,30 – 10) μmol/dm3"}],"search_en":"Seawater Total phosphorus concentration Spectrophotometric method Range PB–31 wydanie 7 z dnia 22.02.2024 r.","technique_en":"Spectrophotometric method","test_object_en":"Seawater","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,30 – 10) μmol/dm3"}],"search_zh":"海水 总磷浓度 分光光度法 范围 PB–31 wydanie 7 z dnia 22.02.2024 r.","technique_zh":"分光光度法","test_object_zh":"海水"},{"_id":"6a837952af14b9c0e7b1fc44","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda morska","methodology":"Stężenie fosforanów","parameters":[{"name":"Zakres","range":"(0,30 – 10) μmol/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforanów\nZakres (0,30 – 10) μmol/dm3\nMetoda spektrofotometryczna","reference":"PB–32 wydanie 7 z dnia 22.02.2024 r.","norm_bases":["PB–32 wydanie 7 z dnia 22.02.2024 r."],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda morska Stężenie fosforanów\nZakres (0,30 – 10) μmol/dm3\nMetoda spektrofotometryczna PB–32 wydanie 7 z dnia 22.02.2024 r. Woda morska Stezenie fosforanow\nZakres (0,30 – 10) μmol/dm3\nMetoda spektrofotometryczna PB–32 wydanie 7 z dnia 22.02.2024 r.","categories":["water"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phosphate concentration","parameters_en":[{"name":"Range","range":"(0,30 – 10) μmol/dm3"}],"search_en":"Seawater Phosphate concentration Spectrophotometric method Range PB–32 wydanie 7 z dnia 22.02.2024 r.","technique_en":"Spectrophotometric method","test_object_en":"Seawater","parameters_zh":[{"name":"范围","range":"(0,30 – 10) μmol/dm3"}],"search_zh":"海水 磷酸盐浓度 分光光度法 范围 PB–32 wydanie 7 z dnia 22.02.2024 r.","technique_zh":"分光光度法","methodology_zh":"磷酸盐浓度","test_object_zh":"海水"},{"_id":"6a837952af14b9c0e7b1fc45","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda powierzchniowa","methodology":"Przeźroczystość (widzialność krążka Secchiego)","parameters":[{"name":"Zakres","range":"(0,1 – 10) m"}],"technique":"Metoda pomiaru bezpośredniego","techniques":["Metoda pomiaru bezpośredniego"],"computed":[],"activity":"Przeźroczystość (widzialność krążka Secchiego)\nZakres (0,1 – 10) m\nMetoda pomiaru bezpośredniego","reference":"PN-EN ISO 7027-2:2019-04 punkt 5.2","norm_bases":["PN-EN ISO 7027-2:2019-04 punkt 5.2"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda powierzchniowa Przeźroczystość (widzialność krążka Secchiego)\nZakres (0,1 – 10) m\nMetoda pomiaru bezpośredniego PN-EN ISO 7027-2:2019-04 punkt 5.2 Woda powierzchniowa Przezroczystosc (widzialnosc krazka Secchiego)\nZakres (0,1 – 10) m\nMetoda pomiaru bezposredniego PN-EN ISO 7027-2:2019-04 punkt 5.2","categories":["water"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Transparency (Secchi disc visibility)","parameters_en":[{"name":"Range","range":"(0,1 – 10) m"}],"search_en":"Surface water Transparency (Secchi disc visibility) Direct measurement method Range PN-EN ISO 7027-2:2019-04 punkt 5.2","technique_en":"Direct measurement method","test_object_en":"Surface water","parameters_zh":[{"name":"范围","range":"(0,1 – 10) m"}],"search_zh":"地表水 直接测量法 范围 PN-EN ISO 7027-2:2019-04 punkt 5.2","test_object_zh":"地表水","technique_zh":"直接测量法"},{"_id":"6a837952af14b9c0e7b1fc46","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda morska, Woda do spożycia przez ludzi","methodology":"Stężenie chloru wolnego","parameters":[{"name":"Zakres","range":"(0,02 – 2,00) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chloru wolnego\nZakres (0,02 – 2,00) mg/dm3\nMetoda spektrofotometryczna","reference":"PB – 49 wydanie 1 z dnia 15.01.2025r. Na podstawie testu HACH 8021","norm_bases":["PB – 49 wydanie 1 z dnia 15.01.2025r. Na podstawie testu HACH 8021"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda morska, Woda do spożycia przez ludzi Stężenie chloru wolnego\nZakres (0,02 – 2,00) mg/dm3\nMetoda spektrofotometryczna PB – 49 wydanie 1 z dnia 15.01.2025r. Na podstawie testu HACH 8021 Woda morska, Woda do spozycia przez ludzi Stezenie chloru wolnego\nZakres (0,02 – 2,00) mg/dm3\nMetoda spektrofotometryczna PB – 49 wydanie 1 z dnia 15.01.2025r. Na podstawie testu HACH 8021","categories":["water"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free chlorine concentration","parameters_en":[{"name":"Range","range":"(0,02 – 2,00) mg/dm3"}],"search_en":"Free chlorine concentration Spectrophotometric method Range PB – 49 wydanie 1 z dnia 15.01.2025r. Na podstawie testu HACH 8021","technique_en":"Spectrophotometric method","methodology_zh":"游离氯浓度","parameters_zh":[{"name":"范围","range":"(0,02 – 2,00) mg/dm3"}],"search_zh":"游离氯浓度 分光光度法 范围 PB – 49 wydanie 1 z dnia 15.01.2025r. Na podstawie testu HACH 8021","technique_zh":"分光光度法"},{"_id":"6a837952af14b9c0e7b1fc47","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,010 –100) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,010 –100) mg/dm3\nMetoda spektrofotometryczna","reference":"PB-06 wydanie 6 z dnia 22.02.2024 r. Na podstawie testu kuwetowego nr 1.14752 MERCK","norm_bases":["PB-06 wydanie 6 z dnia 22.02.2024 r. Na podstawie testu kuwetowego nr 1.14752 MERCK"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie azotu amonowego\nZakres (0,010 –100) mg/dm3\nMetoda spektrofotometryczna PB-06 wydanie 6 z dnia 22.02.2024 r. Na podstawie testu kuwetowego nr 1.14752 MERCK Woda, Woda do spozycia przez ludzi, Scieki Stezenie azotu amonowego\nZakres (0,010 –100) mg/dm3\nMetoda spektrofotometryczna PB-06 wydanie 6 z dnia 22.02.2024 r. Na podstawie testu kuwetowego nr 1.14752 MERCK","categories":["water"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,010 –100) mg/dm3"}],"search_en":"Water, Water intended for human consumption, Wastewater Ammonium nitrogen concentration Spectrophotometric method Range PB-06 wydanie 6 z dnia 22.02.2024 r. Na podstawie testu kuwetowego nr 1.14752 MERCK","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,010 –100) mg/dm3"}],"search_zh":"水、生活饮用水、废水 氨氮浓度 分光光度法 范围 PB-06 wydanie 6 z dnia 22.02.2024 r. Na podstawie testu kuwetowego nr 1.14752 MERCK","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a837952af14b9c0e7b1fc48","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(0,50 – 1000) mg/dm3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (0,50 – 1000) mg/dm3\nMetoda miareczkowa","reference":"PN-EN 25663:2001 z wyłączeniem punktu 5.8 | I-19 wydanie 3 z dnia 26.02.2024 r.","norm_bases":["PN-EN 25663:2001 z wyłączeniem punktu 5.8","I-19 wydanie 3 z dnia 26.02.2024 r."],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie azotu Kjeldahla\nZakres (0,50 – 1000) mg/dm3\nMetoda miareczkowa PN-EN 25663:2001 z wyłączeniem punktu 5.8 | I-19 wydanie 3 z dnia 26.02.2024 r. Woda, Woda do spozycia przez ludzi, Scieki Stezenie azotu Kjeldahla\nZakres (0,50 – 1000) mg/dm3\nMetoda miareczkowa PN-EN 25663:2001 z wylaczeniem punktu 5.8 | I-19 wydanie 3 z dnia 26.02.2024 r.","categories":["water"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,50 – 1000) mg/dm3"}],"search_en":"Water, Water intended for human consumption, Wastewater Kjeldahl nitrogen concentration Titrimetric method Range PN-EN 25663:2001 z wyłączeniem punktu 5.8 | I-19 wydanie 3 z dnia 26.02.2024 r.","technique_en":"Titrimetric method","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(0,50 – 1000) mg/dm3"}],"search_zh":"水、生活饮用水、废水 凯氏氮浓度 滴定法 范围 PN-EN 25663:2001 z wyłączeniem punktu 5.8 | I-19 wydanie 3 z dnia 26.02.2024 r.","technique_zh":"滴定法","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a837952af14b9c0e7b1fc49","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie azotu Kjeldahla (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu Kjeldahla (z obliczeń)","reference":"I-18 wydanie 3 z dnia 26.02.2024 r.","norm_bases":["I-18 wydanie 3 z dnia 26.02.2024 r."],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie azotu Kjeldahla (z obliczeń) I-18 wydanie 3 z dnia 26.02.2024 r. Woda, Woda do spozycia przez ludzi, Scieki Stezenie azotu Kjeldahla (z obliczen) I-18 wydanie 3 z dnia 26.02.2024 r.","categories":["water"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen concentration (calculated)","search_en":"Water, Water intended for human consumption, Wastewater Kjeldahl nitrogen concentration (calculated) I-18 wydanie 3 z dnia 26.02.2024 r.","test_object_en":"Water, Water intended for human consumption, Wastewater","search_zh":"水、生活饮用水、废水 I-18 wydanie 3 z dnia 26.02.2024 r.","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a837952af14b9c0e7b1fc4a","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie azotu ogólnego","parameters":[{"name":"Zakres","range":"(0,50 – 1000) mg/dm3"}],"technique":"Metoda chemiluminescencyjna","techniques":["Metoda chemiluminescencyjna"],"computed":[],"activity":"Stężenie azotu ogólnego\nZakres (0,50 – 1000) mg/dm3\nMetoda chemiluminescencyjna","reference":"PN-EN ISO 20236:2025-05","norm_bases":["PN-EN ISO 20236:2025-05"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie azotu ogólnego\nZakres (0,50 – 1000) mg/dm3\nMetoda chemiluminescencyjna PN-EN ISO 20236:2025-05 Woda, Woda do spozycia przez ludzi, Scieki Stezenie azotu ogolnego\nZakres (0,50 – 1000) mg/dm3\nMetoda chemiluminescencyjna PN-EN ISO 20236:2025-05","categories":["water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,50 – 1000) mg/dm3"}],"search_en":"Water, Water intended for human consumption, Wastewater Total nitrogen concentration Chemiluminescence method Range PN-EN ISO 20236:2025-05","technique_en":"Chemiluminescence method","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology_zh":"总氮浓度","parameters_zh":[{"name":"范围","range":"(0,50 – 1000) mg/dm3"}],"search_zh":"水、生活饮用水、废水 总氮浓度 化学发光法 范围 PN-EN ISO 20236:2025-05","test_object_zh":"水、生活饮用水、废水","technique_zh":"化学发光法"},{"_id":"6a837952af14b9c0e7b1fc4b","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie azotu ogólnego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"I-20 wydanie 3 z dnia 26.02.2024 r.","norm_bases":["I-20 wydanie 3 z dnia 26.02.2024 r."],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie azotu ogólnego (z obliczeń) I-20 wydanie 3 z dnia 26.02.2024 r. Woda, Woda do spozycia przez ludzi, Scieki Stezenie azotu ogolnego (z obliczen) I-20 wydanie 3 z dnia 26.02.2024 r.","categories":["water"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total nitrogen concentration (calculated)","search_en":"Water, Water intended for human consumption, Wastewater Total nitrogen concentration (calculated) I-20 wydanie 3 z dnia 26.02.2024 r.","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology_zh":"总氮浓度（计算值）","search_zh":"水、生活饮用水、废水 总氮浓度（计算值） I-20 wydanie 3 z dnia 26.02.2024 r.","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a837952af14b9c0e7b1fc4c","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie fenolu (indeks fenolowy)","parameters":[{"name":"Zakres","range":"(0,0010 – 0,10) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fenolu (indeks fenolowy)\nZakres (0,0010 – 0,10) mg/dm3\nMetoda spektrofotometryczna","reference":"PN-ISO 6439:1994 metoda B","norm_bases":["PN-ISO 6439:1994 metoda B"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie fenolu (indeks fenolowy)\nZakres (0,0010 – 0,10) mg/dm3\nMetoda spektrofotometryczna PN-ISO 6439:1994 metoda B Woda, Woda do spozycia przez ludzi, Scieki Stezenie fenolu (indeks fenolowy)\nZakres (0,0010 – 0,10) mg/dm3\nMetoda spektrofotometryczna PN-ISO 6439:1994 metoda B","categories":["water"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phenol concentration (phenol index)","parameters_en":[{"name":"Range","range":"(0,0010 – 0,10) mg/dm3"}],"search_en":"Water, Water intended for human consumption, Wastewater Phenol concentration (phenol index) Spectrophotometric method Range PN-ISO 6439:1994 metoda B","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption, Wastewater","parameters_zh":[{"name":"范围","range":"(0,0010 – 0,10) mg/dm3"}],"search_zh":"水、生活饮用水、废水 分光光度法 范围 PN-ISO 6439:1994 metoda B","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a837952af14b9c0e7b1fc4d","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,5"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 12,5\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki pH\nZakres 2,0 – 12,5\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, Woda do spozycia przez ludzi, Scieki pH\nZakres 2,0 – 12,5\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 – 12,5"}],"search_en":"Water, Water intended for human consumption, Wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 12,5"}],"search_zh":"水、生活饮用水、废水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a837952af14b9c0e7b1fc4e","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie anionów","parameters":[{"name":"Fluorki","range":"(0,05 − 100 ) mg/dm3"},{"name":"Azotyny","range":"(0,10 − 50) mg/dm3"},{"name":"Bromki","range":"(0,10 − 50) mg/dm3"},{"name":"Fosforany","range":"(0,20 − 100) mg/dm3"},{"name":"Chlorki","range":"(0,10 – 10 000) mg/dm3"},{"name":"Siarczany","range":"(0,10 − 10 000) mg/dm3"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie anionów\nZakres:\nFluorki (0,05 − 100 ) mg/dm3\nAzotyny (0,10 − 50) mg/dm3\nBromki (0,10 − 50) mg/dm3\nFosforany (0,20 − 100) mg/dm3\nChlorki (0,10 – 10 000) mg/dm3\nSiarczany (0,10 − 10 000) mg/dm3\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie anionów\nZakres:\nFluorki (0,05 − 100 ) mg/dm3\nAzotyny (0,10 − 50) mg/dm3\nBromki (0,10 − 50) mg/dm3\nFosforany (0,20 − 100) mg/dm3\nChlorki (0,10 – 10 000) mg/dm3\nSiarczany (0,10 − 10 000) mg/dm3\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Woda, Woda do spozycia przez ludzi, Scieki Stezenie anionow\nZakres:\nFluorki (0,05 − 100 ) mg/dm3\nAzotyny (0,10 − 50) mg/dm3\nBromki (0,10 − 50) mg/dm3\nFosforany (0,20 − 100) mg/dm3\nChlorki (0,10 – 10 000) mg/dm3\nSiarczany (0,10 − 10 000) mg/dm3\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Anion concentrations","parameters_en":[{"name":"Fluorides","range":"(0,05 − 100 ) mg/dm3"},{"name":"Nitrites","range":"(0,10 − 50) mg/dm3"},{"name":"Bromides","range":"(0,10 − 50) mg/dm3"},{"name":"Phosphates","range":"(0,20 − 100) mg/dm3"},{"name":"Chlorides","range":"(0,10 – 10 000) mg/dm3"},{"name":"Sulfates","range":"(0,10 − 10 000) mg/dm3"}],"search_en":"Water, Water intended for human consumption, Wastewater Anion concentrations Ion chromatography with conductometric detection (IC-CD) Fluorides Nitrites Bromides Phosphates Chlorides Sulfates PN-EN ISO 10304-1:2009+AC:2012","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology_zh":"阴离子浓度","parameters_zh":[{"name":"氟化物","range":"(0,05 − 100 ) mg/dm3"},{"name":"亚硝酸盐","range":"(0,10 − 50) mg/dm3"},{"name":"Bromki","range":"(0,10 − 50) mg/dm3"},{"name":"磷酸盐","range":"(0,20 − 100) mg/dm3"},{"name":"氯化物","range":"(0,10 – 10 000) mg/dm3"},{"name":"硫酸盐","range":"(0,10 − 10 000) mg/dm3"}],"search_zh":"水、生活饮用水、废水 阴离子浓度 离子色谱-电导检测法（IC-CD） 氟化物 亚硝酸盐 磷酸盐 氯化物 硫酸盐 PN-EN ISO 10304-1:2009+AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a837952af14b9c0e7b1fc4f","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Twardość ogólna (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Twardość ogólna (z obliczeń)","reference":"I-11 wydanie 3 z dnia 26.02.2024 r.","norm_bases":["I-11 wydanie 3 z dnia 26.02.2024 r."],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Twardość ogólna (z obliczeń) I-11 wydanie 3 z dnia 26.02.2024 r. Woda, Woda do spozycia przez ludzi, Scieki Twardosc ogolna (z obliczen) I-11 wydanie 3 z dnia 26.02.2024 r.","categories":["water"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total hardness (calculated)","search_en":"Water, Water intended for human consumption, Wastewater Total hardness (calculated) I-11 wydanie 3 z dnia 26.02.2024 r.","test_object_en":"Water, Water intended for human consumption, Wastewater","search_zh":"水、生活饮用水、废水 总硬度（由计算得出） I-11 wydanie 3 z dnia 26.02.2024 r.","test_object_zh":"水、生活饮用水、废水","methodology_zh":"总硬度（由计算得出）"},{"_id":"6a837952af14b9c0e7b1fc50","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Twardość węglanowa (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Twardość węglanowa (z obliczeń)","reference":"I-11 wydanie 3 z dnia 26.02.2024 r.","norm_bases":["I-11 wydanie 3 z dnia 26.02.2024 r."],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Twardość węglanowa (z obliczeń) I-11 wydanie 3 z dnia 26.02.2024 r. Woda, Woda do spozycia przez ludzi, Scieki Twardosc weglanowa (z obliczen) I-11 wydanie 3 z dnia 26.02.2024 r.","categories":["water"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Carbonate hardness (calculated)","search_en":"Water, Water intended for human consumption, Wastewater Carbonate hardness (calculated) I-11 wydanie 3 z dnia 26.02.2024 r.","test_object_en":"Water, Water intended for human consumption, Wastewater","search_zh":"水、生活饮用水、废水 碳酸盐硬度（由计算得出） I-11 wydanie 3 z dnia 26.02.2024 r.","test_object_zh":"水、生活饮用水、废水","methodology_zh":"碳酸盐硬度（由计算得出）"},{"_id":"6a837952af14b9c0e7b1fc51","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Twardość niewęglanowa (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Twardość niewęglanowa (z obliczeń)","reference":"I-11 wydanie 3 z dnia 26.02.2024 r.","norm_bases":["I-11 wydanie 3 z dnia 26.02.2024 r."],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Twardość niewęglanowa (z obliczeń) I-11 wydanie 3 z dnia 26.02.2024 r. Woda, Woda do spozycia przez ludzi, Scieki Twardosc nieweglanowa (z obliczen) I-11 wydanie 3 z dnia 26.02.2024 r.","categories":["water"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Non-carbonate hardness (calculated)","search_en":"Water, Water intended for human consumption, Wastewater Non-carbonate hardness (calculated) I-11 wydanie 3 z dnia 26.02.2024 r.","test_object_en":"Water, Water intended for human consumption, Wastewater","search_zh":"水、生活饮用水、废水 非碳酸盐硬度（由计算得出） I-11 wydanie 3 z dnia 26.02.2024 r.","test_object_zh":"水、生活饮用水、废水","methodology_zh":"非碳酸盐硬度（由计算得出）"},{"_id":"6a837952af14b9c0e7b1fc52","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Twardość magnezowa (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Twardość magnezowa (z obliczeń)","reference":"I-11 wydanie 3 z dnia 26.02.2024 r.","norm_bases":["I-11 wydanie 3 z dnia 26.02.2024 r."],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Twardość magnezowa (z obliczeń) I-11 wydanie 3 z dnia 26.02.2024 r. Woda, Woda do spozycia przez ludzi, Scieki Twardosc magnezowa (z obliczen) I-11 wydanie 3 z dnia 26.02.2024 r.","categories":["water"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnesium hardness (calculated)","search_en":"Water, Water intended for human consumption, Wastewater Magnesium hardness (calculated) I-11 wydanie 3 z dnia 26.02.2024 r.","test_object_en":"Water, Water intended for human consumption, Wastewater","search_zh":"水、生活饮用水、废水 I-11 wydanie 3 z dnia 26.02.2024 r.","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a837952af14b9c0e7b1fc53","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Twardość wapniowa (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Twardość wapniowa (z obliczeń)","reference":"I-11 wydanie 3 z dnia 26.02.2024 r.","norm_bases":["I-11 wydanie 3 z dnia 26.02.2024 r."],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Twardość wapniowa (z obliczeń) I-11 wydanie 3 z dnia 26.02.2024 r. Woda, Woda do spozycia przez ludzi, Scieki Twardosc wapniowa (z obliczen) I-11 wydanie 3 z dnia 26.02.2024 r.","categories":["water"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Calcium hardness (calculated)","search_en":"Water, Water intended for human consumption, Wastewater Calcium hardness (calculated) I-11 wydanie 3 z dnia 26.02.2024 r.","test_object_en":"Water, Water intended for human consumption, Wastewater","search_zh":"水、生活饮用水、废水 I-11 wydanie 3 z dnia 26.02.2024 r.","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a837952af14b9c0e7b1fc54","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie polichlorowanych bifenyli (PCB)","parameters":[{"name":"PCB 28","range":"(1 – 1000) ng/dm3"},{"name":"PCB 52","range":"(1 – 1000) ng/dm3"},{"name":"PCB 101","range":"(1 – 1000) ng/dm3"},{"name":"PCB 118","range":"(1 – 1000) ng/dm3"},{"name":"PCB 138","range":"(1 – 1000) ng/dm3"},{"name":"PCB 153","range":"(1 – 1000) ng/dm3"},{"name":"PCB 180","range":"(1 – 1000) ng/dm3"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Stężenie polichlorowanych bifenyli (PCB)\nZakres:\nPCB 28 (1 – 1000) ng/dm3\nPCB 52 (1 – 1000) ng/dm3\nPCB 101 (1 – 1000) ng/dm3\nPCB 118 (1 – 1000) ng/dm3\nPCB 138 (1 – 1000) ng/dm3\nPCB 153 (1 – 1000) ng/dm3\nPCB 180 (1 – 1000) ng/dm3\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"PB-02 wydanie 6 z dnia 22.02.2024 r.","norm_bases":["PB-02 wydanie 6 z dnia 22.02.2024 r."],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie polichlorowanych bifenyli (PCB)\nZakres:\nPCB 28 (1 – 1000) ng/dm3\nPCB 52 (1 – 1000) ng/dm3\nPCB 101 (1 – 1000) ng/dm3\nPCB 118 (1 – 1000) ng/dm3\nPCB 138 (1 – 1000) ng/dm3\nPCB 153 (1 – 1000) ng/dm3\nPCB 180 (1 – 1000) ng/dm3\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) PB-02 wydanie 6 z dnia 22.02.2024 r. Woda, Woda do spozycia przez ludzi, Scieki Stezenie polichlorowanych bifenyli (PCB)\nZakres:\nPCB 28 (1 – 1000) ng/dm3\nPCB 52 (1 – 1000) ng/dm3\nPCB 101 (1 – 1000) ng/dm3\nPCB 118 (1 – 1000) ng/dm3\nPCB 138 (1 – 1000) ng/dm3\nPCB 153 (1 – 1000) ng/dm3\nPCB 180 (1 – 1000) ng/dm3\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) PB-02 wydanie 6 z dnia 22.02.2024 r.","categories":["water"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Polychlorinated biphenyls (PCB) concentration","parameters_en":[{"name":"PCB 28","range":"(1 – 1000) ng/dm3"},{"name":"PCB 52","range":"(1 – 1000) ng/dm3"},{"name":"PCB 101","range":"(1 – 1000) ng/dm3"},{"name":"PCB 118","range":"(1 – 1000) ng/dm3"},{"name":"PCB 138","range":"(1 – 1000) ng/dm3"},{"name":"PCB 153","range":"(1 – 1000) ng/dm3"},{"name":"PCB 180","range":"(1 – 1000) ng/dm3"}],"search_en":"Water, Water intended for human consumption, Wastewater Polychlorinated biphenyls (PCB) concentration Gas chromatography with mass spectrometry detection (GC-MS) PCB 28 PCB 52 PCB 101 PCB 118 PCB 138 PCB 153 PCB 180 PB-02 wydanie 6 z dnia 22.02.2024 r.","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","test_object_en":"Water, Water intended for human consumption, Wastewater","search_zh":"水、生活饮用水、废水 多氯联苯（PCB）浓度 气相色谱-质谱法（GC-MS） PCB 28 PCB 52 PCB 101 PCB 118 PCB 138 PCB 153 PCB 180 PB-02 wydanie 6 z dnia 22.02.2024 r.","technique_zh":"气相色谱-质谱法（GC-MS）","test_object_zh":"水、生活饮用水、废水","parameters_zh":[{"name":"PCB 28","range":"(1 – 1000) ng/dm3"},{"name":"PCB 52","range":"(1 – 1000) ng/dm3"},{"name":"PCB 101","range":"(1 – 1000) ng/dm3"},{"name":"PCB 118","range":"(1 – 1000) ng/dm3"},{"name":"PCB 138","range":"(1 – 1000) ng/dm3"},{"name":"PCB 153","range":"(1 – 1000) ng/dm3"},{"name":"PCB 180","range":"(1 – 1000) ng/dm3"}],"methodology_zh":"多氯联苯（PCB）浓度"},{"_id":"6a837952af14b9c0e7b1fc55","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Suma polichlorowanych bifenyli (PCB) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma polichlorowanych bifenyli (PCB) (z obliczeń)","reference":"I-24 wydanie 3 z dnia 26.02.2024 r.","norm_bases":["I-24 wydanie 3 z dnia 26.02.2024 r."],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Suma polichlorowanych bifenyli (PCB) (z obliczeń) I-24 wydanie 3 z dnia 26.02.2024 r. Woda, Woda do spozycia przez ludzi, Scieki Suma polichlorowanych bifenyli (PCB) (z obliczen) I-24 wydanie 3 z dnia 26.02.2024 r.","categories":["water"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of polychlorinated biphenyls (PCB) (calculated)","search_en":"Water, Water intended for human consumption, Wastewater Sum of polychlorinated biphenyls (PCB) (calculated) I-24 wydanie 3 z dnia 26.02.2024 r.","test_object_en":"Water, Water intended for human consumption, Wastewater","search_zh":"水、生活饮用水、废水 多氯联苯（PCB）总量（由计算得出） I-24 wydanie 3 z dnia 26.02.2024 r.","test_object_zh":"水、生活饮用水、废水","methodology_zh":"多氯联苯（PCB）总量（由计算得出）"},{"_id":"6a837952af14b9c0e7b1fc56","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Chemiczne zapotrzebowanie tlenu","parameters":[{"name":"ChZT-Cr"},{"name":"Zakres","range":"(10 – 700) mg/dm3 O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (10 – 700) mg/dm3 O2\nMetoda miareczkowa","reference":"PB-19 wydanie 5 z dnia 22.02.2024 r.","norm_bases":["PB-19 wydanie 5 z dnia 22.02.2024 r."],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (10 – 700) mg/dm3 O2\nMetoda miareczkowa PB-19 wydanie 5 z dnia 22.02.2024 r. Woda, Woda do spozycia przez ludzi, Scieki Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (10 – 700) mg/dm3 O2\nMetoda miareczkowa PB-19 wydanie 5 z dnia 22.02.2024 r.","categories":["water"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand","parameters_en":[{"name":"COD-Cr"},{"name":"Range","range":"(10 – 700) mg/dm3 O2"}],"search_en":"Water, Water intended for human consumption, Wastewater Chemical oxygen demand Titrimetric method COD-Cr Range PB-19 wydanie 5 z dnia 22.02.2024 r.","technique_en":"Titrimetric method","test_object_en":"Water, Water intended for human consumption, Wastewater","parameters_zh":[{"name":"化学需氧量（COD-Cr）"},{"name":"范围","range":"(10 – 700) mg/dm3 O2"}],"search_zh":"水、生活饮用水、废水 化学需氧量（COD） 滴定法 化学需氧量（COD-Cr） 范围 PB-19 wydanie 5 z dnia 22.02.2024 r.","technique_zh":"滴定法","test_object_zh":"水、生活饮用水、废水","methodology_zh":"化学需氧量（COD）"},{"_id":"6a837952af14b9c0e7b1fc57","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Chemiczne zapotrzebowanie tlenu","parameters":[{"name":"ChZT-Cr"},{"name":"Zakres","range":"(10 – 5000) mg/dm3 O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (10 – 5000) mg/dm3 O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (10 – 5000) mg/dm3 O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda, Woda do spozycia przez ludzi, Scieki Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (10 – 5000) mg/dm3 O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand","parameters_en":[{"name":"COD-Cr"},{"name":"Range","range":"(10 – 5000) mg/dm3 O2"}],"search_en":"Water, Water intended for human consumption, Wastewater Chemical oxygen demand Spectrophotometric method COD-Cr Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption, Wastewater","parameters_zh":[{"name":"化学需氧量（COD-Cr）"},{"name":"范围","range":"(10 – 5000) mg/dm3 O2"}],"search_zh":"水、生活饮用水、废水 化学需氧量（COD） 分光光度法 化学需氧量（COD-Cr） 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、废水","methodology_zh":"化学需氧量（COD）"},{"_id":"6a837952af14b9c0e7b1fc58","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Ścieki","methodology":"Suma chlorków i siarczanów (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma chlorków i siarczanów (z obliczeń)","reference":"I-24 wydanie 3 z dnia 26.02.2024 r.","norm_bases":["I-24 wydanie 3 z dnia 26.02.2024 r."],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Suma chlorków i siarczanów (z obliczeń) I-24 wydanie 3 z dnia 26.02.2024 r. Scieki Suma chlorkow i siarczanow (z obliczen) I-24 wydanie 3 z dnia 26.02.2024 r.","categories":["water"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of chlorides and sulphates (calculated)","search_en":"Wastewater Sum of chlorides and sulphates (calculated) I-24 wydanie 3 z dnia 26.02.2024 r.","test_object_en":"Wastewater","search_zh":"污水 氯化物与硫酸盐总量（由计算得出） I-24 wydanie 3 z dnia 26.02.2024 r.","test_object_zh":"污水","methodology_zh":"氯化物与硫酸盐总量（由计算得出）"},{"_id":"6a837952af14b9c0e7b1fc59","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie adsorbowalnych związków chlorowcoorganicznych (AOX)","parameters":[{"name":"Zakres","range":"(0,5 - 1000) mg/dm3 Cl"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie adsorbowalnych związków chlorowcoorganicznych (AOX)\nZakres (0,5 - 1000) mg/dm3 Cl\nMetoda spektrofotometryczna","reference":"PB-35 wydanie 5 z dnia 22.02.2024 r.","norm_bases":["PB-35 wydanie 5 z dnia 22.02.2024 r."],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie adsorbowalnych związków chlorowcoorganicznych (AOX)\nZakres (0,5 - 1000) mg/dm3 Cl\nMetoda spektrofotometryczna PB-35 wydanie 5 z dnia 22.02.2024 r. Scieki Stezenie adsorbowalnych zwiazkow chlorowcoorganicznych (AOX)\nZakres (0,5 - 1000) mg/dm3 Cl\nMetoda spektrofotometryczna PB-35 wydanie 5 z dnia 22.02.2024 r.","categories":["water"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Adsorbable organic halogen compounds (AOX) concentration","parameters_en":[{"name":"Range","range":"(0,5 - 1000) mg/dm3 Cl"}],"search_en":"Wastewater Adsorbable organic halogen compounds (AOX) concentration Spectrophotometric method Range PB-35 wydanie 5 z dnia 22.02.2024 r.","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(0,5 - 1000) mg/dm3 Cl"}],"search_zh":"污水 分光光度法 范围 PB-35 wydanie 5 z dnia 22.02.2024 r.","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a837952af14b9c0e7b1fc5a","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Ścieki","methodology":"Azotany (0,10 − 500) mg/dm3","parameters":[],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Azotany (0,10 − 500) mg/dm3\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Azotany (0,10 − 500) mg/dm3\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Scieki Azotany (0,10 − 500) mg/dm3\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Wastewater Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Wastewater","search_zh":"污水 离子色谱-电导检测法（IC-CD） PN-EN ISO 10304-1:2009+AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"污水"},{"_id":"6a837952af14b9c0e7b1fc5b","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie arsenu","parameters":[{"name":"Zakres","range":"(0,001 – 0,050) mg/dm3"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES)"],"computed":[],"activity":"Stężenie arsenu\nZakres (0,001 – 0,050) mg/dm3\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES)","reference":"PB- 25 wydanie 5 z dnia 22.02.2024 r.","norm_bases":["PB- 25 wydanie 5 z dnia 22.02.2024 r."],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie arsenu\nZakres (0,001 – 0,050) mg/dm3\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES) PB- 25 wydanie 5 z dnia 22.02.2024 r. Woda, Woda do spozycia przez ludzi, Scieki Stezenie arsenu\nZakres (0,001 – 0,050) mg/dm3\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej z generowaniem wodorkow (HG-ICP-OES) PB- 25 wydanie 5 z dnia 22.02.2024 r.","categories":["water"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Arsenic concentration","parameters_en":[{"name":"Range","range":"(0,001 – 0,050) mg/dm3"}],"search_en":"Water, Water intended for human consumption, Wastewater Arsenic concentration Hydride generation inductively coupled plasma optical emission spectrometry (HG-ICP-OES) Range PB- 25 wydanie 5 z dnia 22.02.2024 r.","technique_en":"Hydride generation inductively coupled plasma optical emission spectrometry (HG-ICP-OES)","test_object_en":"Water, Water intended for human consumption, Wastewater","parameters_zh":[{"name":"范围","range":"(0,001 – 0,050) mg/dm3"}],"search_zh":"水、生活饮用水、废水 砷浓度 氢化物发生电感耦合等离子体发射光谱法（HG-ICP-OES） 范围 PB- 25 wydanie 5 z dnia 22.02.2024 r.","test_object_zh":"水、生活饮用水、废水","technique_zh":"氢化物发生电感耦合等离子体发射光谱法（HG-ICP-OES）","methodology_zh":"砷浓度"},{"_id":"6a837952af14b9c0e7b1fc5c","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie antymonu","parameters":[{"name":"Zakres","range":"(0,001 – 0,050) mg/dm3"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES)"],"computed":[],"activity":"Stężenie antymonu\nZakres (0,001 – 0,050) mg/dm3\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES)","reference":"PB-18 wydanie 6 z dnia 26.02.2024 r.","norm_bases":["PB-18 wydanie 6 z dnia 26.02.2024 r."],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie antymonu\nZakres (0,001 – 0,050) mg/dm3\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES) PB-18 wydanie 6 z dnia 26.02.2024 r. Woda, Woda do spozycia przez ludzi, Scieki Stezenie antymonu\nZakres (0,001 – 0,050) mg/dm3\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej z generowaniem wodorkow (HG-ICP-OES) PB-18 wydanie 6 z dnia 26.02.2024 r.","categories":["water"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Antimony concentration","parameters_en":[{"name":"Range","range":"(0,001 – 0,050) mg/dm3"}],"search_en":"Water, Water intended for human consumption, Wastewater Antimony concentration Hydride generation inductively coupled plasma optical emission spectrometry (HG-ICP-OES) Range PB-18 wydanie 6 z dnia 26.02.2024 r.","technique_en":"Hydride generation inductively coupled plasma optical emission spectrometry (HG-ICP-OES)","test_object_en":"Water, Water intended for human consumption, Wastewater","parameters_zh":[{"name":"范围","range":"(0,001 – 0,050) mg/dm3"}],"search_zh":"水、生活饮用水、废水 锑浓度 氢化物发生电感耦合等离子体发射光谱法（HG-ICP-OES） 范围 PB-18 wydanie 6 z dnia 26.02.2024 r.","test_object_zh":"水、生活饮用水、废水","technique_zh":"氢化物发生电感耦合等离子体发射光谱法（HG-ICP-OES）","methodology_zh":"锑浓度"},{"_id":"6a837952af14b9c0e7b1fc5d","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie selenu","parameters":[{"name":"Zakres","range":"(0,001 – 0,050) mg/dm3"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES)"],"computed":[],"activity":"Stężenie selenu\nZakres (0,001 – 0,050) mg/dm3\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES)","reference":"PB-26 wydanie 5 z dnia 22.02.2024 r.","norm_bases":["PB-26 wydanie 5 z dnia 22.02.2024 r."],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie selenu\nZakres (0,001 – 0,050) mg/dm3\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES) PB-26 wydanie 5 z dnia 22.02.2024 r. Woda, Woda do spozycia przez ludzi, Scieki Stezenie selenu\nZakres (0,001 – 0,050) mg/dm3\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej z generowaniem wodorkow (HG-ICP-OES) PB-26 wydanie 5 z dnia 22.02.2024 r.","categories":["water"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Selenium concentration","parameters_en":[{"name":"Range","range":"(0,001 – 0,050) mg/dm3"}],"search_en":"Water, Water intended for human consumption, Wastewater Selenium concentration Hydride generation inductively coupled plasma optical emission spectrometry (HG-ICP-OES) Range PB-26 wydanie 5 z dnia 22.02.2024 r.","technique_en":"Hydride generation inductively coupled plasma optical emission spectrometry (HG-ICP-OES)","test_object_en":"Water, Water intended for human consumption, Wastewater","parameters_zh":[{"name":"范围","range":"(0,001 – 0,050) mg/dm3"}],"search_zh":"水、生活饮用水、废水 硒浓度 氢化物发生电感耦合等离子体发射光谱法（HG-ICP-OES） 范围 PB-26 wydanie 5 z dnia 22.02.2024 r.","test_object_zh":"水、生活饮用水、废水","technique_zh":"氢化物发生电感耦合等离子体发射光谱法（HG-ICP-OES）","methodology_zh":"硒浓度"},{"_id":"6a837952af14b9c0e7b1fc5e","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie BTEX","parameters":[{"name":"Benzen","range":"(0,03 – 150) μg/dm3"},{"name":"Etylobenzen","range":"(0,03 – 150) μg/dm3"},{"name":"Toulen","range":"(0,03 – 150) μg/dm3"},{"name":"m+p Ksylen","range":"(0,03 – 300) μg/dm3"},{"name":"o-Ksylen","range":"(0,03 – 150) μg/dm3"},{"name":"Styren","range":"(0,03 – 150) μg/dm3"}],"technique":"Metoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją płomieniowo-jonizacyjną (P&T GC-FID)","techniques":["Metoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją płomieniowo-jonizacyjną (P&T GC-FID)"],"computed":[],"activity":"Stężenie BTEX\nZakres:\nBenzen (0,03 – 150) μg/dm3\nEtylobenzen (0,03 – 150) μg/dm3\nToulen (0,03 – 150) μg/dm3\nm+p Ksylen (0,03 – 300) μg/dm3\no-Ksylen (0,03 – 150) μg/dm3\nStyren (0,03 – 150) μg/dm3\nMetoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją płomieniowo-jonizacyjną (P&T GC-FID)","reference":"PN-EN ISO 15680:2008","norm_bases":["PN-EN ISO 15680:2008"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie BTEX\nZakres:\nBenzen (0,03 – 150) μg/dm3\nEtylobenzen (0,03 – 150) μg/dm3\nToulen (0,03 – 150) μg/dm3\nm+p Ksylen (0,03 – 300) μg/dm3\no-Ksylen (0,03 – 150) μg/dm3\nStyren (0,03 – 150) μg/dm3\nMetoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją płomieniowo-jonizacyjną (P&T GC-FID) PN-EN ISO 15680:2008 Woda, Woda do spozycia przez ludzi, Scieki Stezenie BTEX\nZakres:\nBenzen (0,03 – 150) μg/dm3\nEtylobenzen (0,03 – 150) μg/dm3\nToulen (0,03 – 150) μg/dm3\nm+p Ksylen (0,03 – 300) μg/dm3\no-Ksylen (0,03 – 150) μg/dm3\nStyren (0,03 – 150) μg/dm3\nMetoda chromatografii gazowej z technika wylapywania i wyplukiwania (Purge&Trap) i detekcja plomieniowo-jonizacyjna (P&T GC-FID) PN-EN ISO 15680:2008","categories":["water"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"BTEX concentration","parameters_en":[{"name":"Benzene","range":"(0,03 – 150) μg/dm3"},{"name":"Ethylbenzene","range":"(0,03 – 150) μg/dm3"},{"name":"Toluene","range":"(0,03 – 150) μg/dm3"},{"name":"m+p Xylene","range":"(0,03 – 300) μg/dm3"},{"name":"o-Xylene","range":"(0,03 – 150) μg/dm3"},{"name":"Styrene","range":"(0,03 – 150) μg/dm3"}],"search_en":"Water, Water intended for human consumption, Wastewater BTEX concentration Gas chromatography with purge and trap technique (Purge&Trap) and flame ionization detection (P&T GC-FID) Benzene Ethylbenzene Toluene m+p Xylene o-Xylene Styrene PN-EN ISO 15680:2008","technique_en":"Gas chromatography with purge and trap technique (Purge&Trap) and flame ionization detection (P&T GC-FID)","test_object_en":"Water, Water intended for human consumption, Wastewater","search_zh":"水、生活饮用水、废水 苯 乙苯 邻二甲苯 苯乙烯 PN-EN ISO 15680:2008","test_object_zh":"水、生活饮用水、废水","parameters_zh":[{"name":"苯","range":"(0,03 – 150) μg/dm3"},{"name":"乙苯","range":"(0,03 – 150) μg/dm3"},{"name":"Toulen","range":"(0,03 – 150) μg/dm3"},{"name":"m+p Ksylen","range":"(0,03 – 300) μg/dm3"},{"name":"邻二甲苯","range":"(0,03 – 150) μg/dm3"},{"name":"苯乙烯","range":"(0,03 – 150) μg/dm3"}]},{"_id":"6a837952af14b9c0e7b1fc5f","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Suma BTEX i BTX (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma BTEX i BTX (z obliczeń)","reference":"I-24 wydanie 3 z dnia 26.02.2024 r.","norm_bases":["I-24 wydanie 3 z dnia 26.02.2024 r."],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Suma BTEX i BTX (z obliczeń) I-24 wydanie 3 z dnia 26.02.2024 r. Woda, Woda do spozycia przez ludzi, Scieki Suma BTEX i BTX (z obliczen) I-24 wydanie 3 z dnia 26.02.2024 r.","categories":["water"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of BTEX and BTX (calculated)","search_en":"Water, Water intended for human consumption, Wastewater Sum of BTEX and BTX (calculated) I-24 wydanie 3 z dnia 26.02.2024 r.","test_object_en":"Water, Water intended for human consumption, Wastewater","search_zh":"水、生活饮用水、废水 I-24 wydanie 3 z dnia 26.02.2024 r.","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a837952af14b9c0e7b1fc60","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie BTEX","parameters":[{"name":"Benzen","range":"(0,03 – 150) μg/dm3"},{"name":"Etylobenzen","range":"(0,03 – 150) μg/dm3"},{"name":"Toluen","range":"(0,03 – 150) μg/dm3"},{"name":"m+p-Ksylen","range":"(0,03 – 300) μg/dm3"},{"name":"o-Ksylen","range":"(0,03 – 150) μg/dm3"},{"name":"Styren","range":"(0,03 – 150) μg/dm3"}],"technique":"Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)","techniques":["Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)"],"computed":[],"activity":"Stężenie BTEX\nZakres:\nBenzen (0,03 – 150) μg/dm3\nEtylobenzen (0,03 – 150) μg/dm3\nToluen (0,03 – 150) μg/dm3\nm+p-Ksylen (0,03 – 300) μg/dm3\no-Ksylen (0,03 – 150) μg/dm3\nStyren (0,03 – 150) μg/dm3\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)","reference":"PB-47 wydanie 2 z 22.02.2024 r.","norm_bases":["PB-47 wydanie 2 z 22.02.2024 r."],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie BTEX\nZakres:\nBenzen (0,03 – 150) μg/dm3\nEtylobenzen (0,03 – 150) μg/dm3\nToluen (0,03 – 150) μg/dm3\nm+p-Ksylen (0,03 – 300) μg/dm3\no-Ksylen (0,03 – 150) μg/dm3\nStyren (0,03 – 150) μg/dm3\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS) PB-47 wydanie 2 z 22.02.2024 r. Woda, Woda do spozycia przez ludzi, Scieki Stezenie BTEX\nZakres:\nBenzen (0,03 – 150) μg/dm3\nEtylobenzen (0,03 – 150) μg/dm3\nToluen (0,03 – 150) μg/dm3\nm+p-Ksylen (0,03 – 300) μg/dm3\no-Ksylen (0,03 – 150) μg/dm3\nStyren (0,03 – 150) μg/dm3\nMetoda chromatografii gazowej z analiza fazy nadpowierzchniowej i detekcja spektrometria mas (HS-GC-MS) PB-47 wydanie 2 z 22.02.2024 r.","categories":["water"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"BTEX concentration","parameters_en":[{"name":"Benzene","range":"(0,03 – 150) μg/dm3"},{"name":"Ethylbenzene","range":"(0,03 – 150) μg/dm3"},{"name":"Toluene","range":"(0,03 – 150) μg/dm3"},{"name":"m+p-Xylene","range":"(0,03 – 300) μg/dm3"},{"name":"o-Xylene","range":"(0,03 – 150) μg/dm3"},{"name":"Styrene","range":"(0,03 – 150) μg/dm3"}],"search_en":"Water, Water intended for human consumption, Wastewater BTEX concentration Headspace gas chromatography with mass spectrometry detection (HS-GC-MS) Benzene Ethylbenzene Toluene m+p-Xylene o-Xylene Styrene PB-47 wydanie 2 z 22.02.2024 r.","technique_en":"Headspace gas chromatography with mass spectrometry detection (HS-GC-MS)","test_object_en":"Water, Water intended for human consumption, Wastewater","search_zh":"水、生活饮用水、废水 顶空气相色谱-质谱法（HS-GC-MS） 苯 乙苯 甲苯 邻二甲苯 苯乙烯 PB-47 wydanie 2 z 22.02.2024 r.","test_object_zh":"水、生活饮用水、废水","technique_zh":"顶空气相色谱-质谱法（HS-GC-MS）","parameters_zh":[{"name":"苯","range":"(0,03 – 150) μg/dm3"},{"name":"乙苯","range":"(0,03 – 150) μg/dm3"},{"name":"甲苯","range":"(0,03 – 150) μg/dm3"},{"name":"m+p-Ksylen","range":"(0,03 – 300) μg/dm3"},{"name":"邻二甲苯","range":"(0,03 – 150) μg/dm3"},{"name":"苯乙烯","range":"(0,03 – 150) μg/dm3"}]},{"_id":"6a837952af14b9c0e7b1fc61","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie węgla:","parameters":[{"name":"ogólnego węgla organicznego (TOC)"},{"name":"Zakres","range":"(0,5 – 500) mg/dm3"},{"name":"całkowitego węgla (TC)"},{"name":"Zakres","range":"(0,5 – 500) mg/dm3"},{"name":"węgla nieorganicznego (IC)"},{"name":"Zakres","range":"(0,5 – 500) mg/dm3"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Stężenie węgla:\nZakres:\nogólnego węgla organicznego (TOC)\nZakres (0,5 – 500) mg/dm3\ncałkowitego węgla (TC)\nZakres (0,5 – 500) mg/dm3\nwęgla nieorganicznego (IC)\nZakres (0,5 – 500) mg/dm3\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN 1484:1999","norm_bases":["PN-EN 1484:1999"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie węgla:\nZakres:\nogólnego węgla organicznego (TOC)\nZakres (0,5 – 500) mg/dm3\ncałkowitego węgla (TC)\nZakres (0,5 – 500) mg/dm3\nwęgla nieorganicznego (IC)\nZakres (0,5 – 500) mg/dm3\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN 1484:1999 Woda, Scieki Stezenie wegla:\nZakres:\nogolnego wegla organicznego (TOC)\nZakres (0,5 – 500) mg/dm3\ncalkowitego wegla (TC)\nZakres (0,5 – 500) mg/dm3\nwegla nieorganicznego (IC)\nZakres (0,5 – 500) mg/dm3\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN 1484:1999","categories":["water"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Carbon concentration:","parameters_en":[{"name":"total organic carbon (TOC)"},{"name":"Range","range":"(0,5 – 500) mg/dm3"},{"name":"total carbon (TC)"},{"name":"Range","range":"(0,5 – 500) mg/dm3"},{"name":"inorganic carbon (IC)"},{"name":"Range","range":"(0,5 – 500) mg/dm3"}],"search_en":"Water, Wastewater Carbon concentration: High-temperature combustion with IR detection total organic carbon (TOC) Range total carbon (TC) Range inorganic carbon (IC) Range PN-EN 1484:1999","technique_en":"High-temperature combustion with IR detection","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"ogólnego węgla organicznego (TOC)"},{"name":"范围","range":"(0,5 – 500) mg/dm3"},{"name":"całkowitego węgla (TC)"},{"name":"范围","range":"(0,5 – 500) mg/dm3"},{"name":"węgla nieorganicznego (IC)"},{"name":"范围","range":"(0,5 – 500) mg/dm3"}],"search_zh":"水、污水 高温燃烧红外检测法 范围 范围 范围 PN-EN 1484:1999","technique_zh":"高温燃烧红外检测法","test_object_zh":"水、污水"},{"_id":"6a837952af14b9c0e7b1fc62","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie węgla:","parameters":[{"name":"ogólnego węgla organicznego (TOC)"},{"name":"Zakres","range":"(0,5 – 100) mg/dm3"},{"name":"całkowitego węgla (TC)"},{"name":"Zakres","range":"(0,5 – 100) mg/dm3"},{"name":"węgla nieorganicznego (IC)"},{"name":"Zakres","range":"(0,5 – 100) mg/dm3"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Stężenie węgla:\nZakres:\nogólnego węgla organicznego (TOC)\nZakres (0,5 – 100) mg/dm3\ncałkowitego węgla (TC)\nZakres (0,5 – 100) mg/dm3\nwęgla nieorganicznego (IC)\nZakres (0,5 – 100) mg/dm3\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN 1484:1999","norm_bases":["PN-EN 1484:1999"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie węgla:\nZakres:\nogólnego węgla organicznego (TOC)\nZakres (0,5 – 100) mg/dm3\ncałkowitego węgla (TC)\nZakres (0,5 – 100) mg/dm3\nwęgla nieorganicznego (IC)\nZakres (0,5 – 100) mg/dm3\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN 1484:1999 Woda do spozycia przez ludzi Stezenie wegla:\nZakres:\nogolnego wegla organicznego (TOC)\nZakres (0,5 – 100) mg/dm3\ncalkowitego wegla (TC)\nZakres (0,5 – 100) mg/dm3\nwegla nieorganicznego (IC)\nZakres (0,5 – 100) mg/dm3\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN 1484:1999","categories":["water"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Carbon concentration:","parameters_en":[{"name":"total organic carbon (TOC)"},{"name":"Range","range":"(0,5 – 100) mg/dm3"},{"name":"total carbon (TC)"},{"name":"Range","range":"(0,5 – 100) mg/dm3"},{"name":"inorganic carbon (IC)"},{"name":"Range","range":"(0,5 – 100) mg/dm3"}],"search_en":"Water intended for human consumption Carbon concentration: High-temperature combustion with IR detection total organic carbon (TOC) Range total carbon (TC) Range inorganic carbon (IC) Range PN-EN 1484:1999","technique_en":"High-temperature combustion with IR detection","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"ogólnego węgla organicznego (TOC)"},{"name":"范围","range":"(0,5 – 100) mg/dm3"},{"name":"całkowitego węgla (TC)"},{"name":"范围","range":"(0,5 – 100) mg/dm3"},{"name":"węgla nieorganicznego (IC)"},{"name":"范围","range":"(0,5 – 100) mg/dm3"}],"search_zh":"生活饮用水 高温燃烧红外检测法 范围 范围 范围 PN-EN 1484:1999","technique_zh":"高温燃烧红外检测法","test_object_zh":"生活饮用水"},{"_id":"6a837952af14b9c0e7b1fc63","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda morska","methodology":"Stężenie węgla:","parameters":[{"name":"ogólnego węgla organicznego (TOC)"},{"name":"Zakres","range":"(0,5 – 20) mg/dm3"},{"name":"całkowitego węgla (TC)"},{"name":"Zakres","range":"(0,5 – 20) mg/dm3"},{"name":"węgla nieorganicznego (IC)"},{"name":"Zakres","range":"(0,5 – 20) mg/dm3"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Stężenie węgla:\nZakres:\nogólnego węgla organicznego (TOC)\nZakres (0,5 – 20) mg/dm3\ncałkowitego węgla (TC)\nZakres (0,5 – 20) mg/dm3\nwęgla nieorganicznego (IC)\nZakres (0,5 – 20) mg/dm3\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN 1484:1999","norm_bases":["PN-EN 1484:1999"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda morska Stężenie węgla:\nZakres:\nogólnego węgla organicznego (TOC)\nZakres (0,5 – 20) mg/dm3\ncałkowitego węgla (TC)\nZakres (0,5 – 20) mg/dm3\nwęgla nieorganicznego (IC)\nZakres (0,5 – 20) mg/dm3\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN 1484:1999 Woda morska Stezenie wegla:\nZakres:\nogolnego wegla organicznego (TOC)\nZakres (0,5 – 20) mg/dm3\ncalkowitego wegla (TC)\nZakres (0,5 – 20) mg/dm3\nwegla nieorganicznego (IC)\nZakres (0,5 – 20) mg/dm3\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN 1484:1999","categories":["water"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Carbon concentration:","parameters_en":[{"name":"total organic carbon (TOC)"},{"name":"Range","range":"(0,5 – 20) mg/dm3"},{"name":"total carbon (TC)"},{"name":"Range","range":"(0,5 – 20) mg/dm3"},{"name":"inorganic carbon (IC)"},{"name":"Range","range":"(0,5 – 20) mg/dm3"}],"search_en":"Seawater Carbon concentration: High-temperature combustion with IR detection total organic carbon (TOC) Range total carbon (TC) Range inorganic carbon (IC) Range PN-EN 1484:1999","technique_en":"High-temperature combustion with IR detection","test_object_en":"Seawater","parameters_zh":[{"name":"ogólnego węgla organicznego (TOC)"},{"name":"范围","range":"(0,5 – 20) mg/dm3"},{"name":"całkowitego węgla (TC)"},{"name":"范围","range":"(0,5 – 20) mg/dm3"},{"name":"węgla nieorganicznego (IC)"},{"name":"范围","range":"(0,5 – 20) mg/dm3"}],"search_zh":"海水 高温燃烧红外检测法 范围 范围 范围 PN-EN 1484:1999","technique_zh":"高温燃烧红外检测法","test_object_zh":"海水"},{"_id":"6a837952af14b9c0e7b1fc64","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie cyjanków wolnych","parameters":[{"name":"Zakres","range":"(0,005 – 15,0) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie cyjanków wolnych\nZakres (0,005 – 15,0) mg/dm3\nMetoda spektrofotometryczna","reference":"PN-C-04603-01:1980","norm_bases":["PN-C-04603-01:1980"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie cyjanków wolnych\nZakres (0,005 – 15,0) mg/dm3\nMetoda spektrofotometryczna PN-C-04603-01:1980 Woda Stezenie cyjankow wolnych\nZakres (0,005 – 15,0) mg/dm3\nMetoda spektrofotometryczna PN-C-04603-01:1980","categories":["water"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free cyanide concentration","parameters_en":[{"name":"Range","range":"(0,005 – 15,0) mg/dm3"}],"search_en":"Water Free cyanide concentration Spectrophotometric method Range PN-C-04603-01:1980","technique_en":"Spectrophotometric method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,005 – 15,0) mg/dm3"}],"search_zh":"水 游离氰化物浓度 分光光度法 范围 PN-C-04603-01:1980","technique_zh":"分光光度法","test_object_zh":"水","methodology_zh":"游离氰化物浓度"},{"_id":"6a837952af14b9c0e7b1fc65","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie cyjanków związanych","parameters":[{"name":"Zakres","range":"(0,005 – 15,0) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie cyjanków związanych\nZakres (0,005 – 15,0) mg/dm3\nMetoda spektrofotometryczna","reference":"PN-C-04603-01:1980","norm_bases":["PN-C-04603-01:1980"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie cyjanków związanych\nZakres (0,005 – 15,0) mg/dm3\nMetoda spektrofotometryczna PN-C-04603-01:1980 Woda Stezenie cyjankow zwiazanych\nZakres (0,005 – 15,0) mg/dm3\nMetoda spektrofotometryczna PN-C-04603-01:1980","categories":["water"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Bound cyanide concentration","parameters_en":[{"name":"Range","range":"(0,005 – 15,0) mg/dm3"}],"search_en":"Water Bound cyanide concentration Spectrophotometric method Range PN-C-04603-01:1980","technique_en":"Spectrophotometric method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,005 – 15,0) mg/dm3"}],"search_zh":"水 络合氰化物浓度 分光光度法 范围 PN-C-04603-01:1980","technique_zh":"分光光度法","test_object_zh":"水","methodology_zh":"络合氰化物浓度"},{"_id":"6a837952af14b9c0e7b1fc66","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie cyjanków ogólnych","parameters":[{"name":"Zakres","range":"(0,05 – 15,0) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie cyjanków ogólnych\nZakres (0,05 – 15,0) mg/dm3\nMetoda spektrofotometryczna","reference":"PN-C-04603-01:1980","norm_bases":["PN-C-04603-01:1980"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie cyjanków ogólnych\nZakres (0,05 – 15,0) mg/dm3\nMetoda spektrofotometryczna PN-C-04603-01:1980 Woda Stezenie cyjankow ogolnych\nZakres (0,05 – 15,0) mg/dm3\nMetoda spektrofotometryczna PN-C-04603-01:1980","categories":["water"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total cyanide concentration","parameters_en":[{"name":"Range","range":"(0,05 – 15,0) mg/dm3"}],"search_en":"Water Total cyanide concentration Spectrophotometric method Range PN-C-04603-01:1980","technique_en":"Spectrophotometric method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,05 – 15,0) mg/dm3"}],"search_zh":"水 总氰化物浓度 分光光度法 范围 PN-C-04603-01:1980","technique_zh":"分光光度法","test_object_zh":"水","methodology_zh":"总氰化物浓度"},{"_id":"6a837952af14b9c0e7b1fc67","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie 17β-estradiolu (E2)","parameters":[{"name":"Zakres","range":"(0,010 –1,0) μg/dm3"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Stężenie 17β-estradiolu (E2)\nZakres (0,010 –1,0) μg/dm3\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"PB-46 wydanie 3 z dnia 22.02.2024 r.","norm_bases":["PB-46 wydanie 3 z dnia 22.02.2024 r."],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie 17β-estradiolu (E2)\nZakres (0,010 –1,0) μg/dm3\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) PB-46 wydanie 3 z dnia 22.02.2024 r. Woda Stezenie 17β-estradiolu (E2)\nZakres (0,010 –1,0) μg/dm3\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) PB-46 wydanie 3 z dnia 22.02.2024 r.","categories":["water"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"17β-estradiol (E2) concentration","parameters_en":[{"name":"Range","range":"(0,010 –1,0) μg/dm3"}],"search_en":"Water 17β-estradiol (E2) concentration Gas chromatography with mass spectrometry detection (GC-MS) Range PB-46 wydanie 3 z dnia 22.02.2024 r.","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,010 –1,0) μg/dm3"}],"search_zh":"水 气相色谱-质谱法（GC-MS） 范围 PB-46 wydanie 3 z dnia 22.02.2024 r.","technique_zh":"气相色谱-质谱法（GC-MS）","test_object_zh":"水"},{"_id":"6a837952af14b9c0e7b1fc68","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie 17β-estradiolu (E2)","parameters":[{"name":"Zakres","range":"(0,0010 –1,0) μg/dm3"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Stężenie 17β-estradiolu (E2)\nZakres (0,0010 –1,0) μg/dm3\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"PB-46 wydanie 3 z dnia 22.02.2024 r.","norm_bases":["PB-46 wydanie 3 z dnia 22.02.2024 r."],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie 17β-estradiolu (E2)\nZakres (0,0010 –1,0) μg/dm3\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) PB-46 wydanie 3 z dnia 22.02.2024 r. Woda do spozycia przez ludzi Stezenie 17β-estradiolu (E2)\nZakres (0,0010 –1,0) μg/dm3\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) PB-46 wydanie 3 z dnia 22.02.2024 r.","categories":["water"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"17β-estradiol (E2) concentration","parameters_en":[{"name":"Range","range":"(0,0010 –1,0) μg/dm3"}],"search_en":"Water intended for human consumption 17β-estradiol (E2) concentration Gas chromatography with mass spectrometry detection (GC-MS) Range PB-46 wydanie 3 z dnia 22.02.2024 r.","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,0010 –1,0) μg/dm3"}],"search_zh":"生活饮用水 气相色谱-质谱法（GC-MS） 范围 PB-46 wydanie 3 z dnia 22.02.2024 r.","technique_zh":"气相色谱-质谱法（GC-MS）","test_object_zh":"生活饮用水"},{"_id":"6a837952af14b9c0e7b1fc69","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda","methodology":"Potencjał redukująco-utleniający (redox) wzgl. SEW","parameters":[{"name":"Zakres","range":"(-100 – 1000) mV"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"Potencjał redukująco-utleniający (redox) wzgl. SEW\nZakres (-100 – 1000) mV\nMetoda potencjometryczna","reference":"PB-48 wydanie 2 z dnia 22.02.2024 r.","norm_bases":["PB-48 wydanie 2 z dnia 22.02.2024 r."],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Potencjał redukująco-utleniający (redox) wzgl. SEW\nZakres (-100 – 1000) mV\nMetoda potencjometryczna PB-48 wydanie 2 z dnia 22.02.2024 r. Woda Potencjal redukujaco-utleniajacy (redox) wzgl. SEW\nZakres (-100 – 1000) mV\nMetoda potencjometryczna PB-48 wydanie 2 z dnia 22.02.2024 r.","categories":["water"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Reduction-oxidation (redox) potential ref. to SHE","parameters_en":[{"name":"Range","range":"(-100 – 1000) mV"}],"search_en":"Water Reduction-oxidation (redox) potential ref. to SHE Potentiometric method Range PB-48 wydanie 2 z dnia 22.02.2024 r.","technique_en":"Potentiometric method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(-100 – 1000) mV"}],"search_zh":"水 电位法 范围 PB-48 wydanie 2 z dnia 22.02.2024 r.","technique_zh":"电位法","test_object_zh":"水"},{"_id":"6a837952af14b9c0e7b1fc6a","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Potencjał redukująco-utleniający (redox) wzgl. Ag/AgCl 3,5 mol/l KCl","parameters":[{"name":"Zakres","range":"(-280 – 850) mV"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"Potencjał redukująco-utleniający (redox) wzgl. Ag/AgCl 3,5 mol/l KCl\nZakres (-280 – 850) mV\nMetoda potencjometryczna","reference":"PB-48 wydanie 2 z dnia 22.02.2024 r.","norm_bases":["PB-48 wydanie 2 z dnia 22.02.2024 r."],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Potencjał redukująco-utleniający (redox) wzgl. Ag/AgCl 3,5 mol/l KCl\nZakres (-280 – 850) mV\nMetoda potencjometryczna PB-48 wydanie 2 z dnia 22.02.2024 r. Woda na plywalniach Potencjal redukujaco-utleniajacy (redox) wzgl. Ag/AgCl 3,5 mol/l KCl\nZakres (-280 – 850) mV\nMetoda potencjometryczna PB-48 wydanie 2 z dnia 22.02.2024 r.","categories":["water"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Reduction-oxidation (redox) potential ref. to Ag/AgCl 3,5 mol/l KCl","parameters_en":[{"name":"Range","range":"(-280 – 850) mV"}],"search_en":"Swimming pool water Reduction-oxidation (redox) potential ref. to Ag/AgCl 3,5 mol/l KCl Potentiometric method Range PB-48 wydanie 2 z dnia 22.02.2024 r.","technique_en":"Potentiometric method","test_object_en":"Swimming pool water","parameters_zh":[{"name":"范围","range":"(-280 – 850) mV"}],"search_zh":"游泳池水 电位法 范围 PB-48 wydanie 2 z dnia 22.02.2024 r.","technique_zh":"电位法","test_object_zh":"游泳池水"},{"_id":"6a837952af14b9c0e7b1fc6b","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Indeks nadmanganianowy","parameters":[{"name":"Zakres","range":"(0,5 – 100) mg/dm3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Indeks nadmanganianowy\nZakres (0,5 – 100) mg/dm3\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Indeks nadmanganianowy\nZakres (0,5 – 100) mg/dm3\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda, Woda do spozycia przez ludzi Indeks nadmanganianowy\nZakres (0,5 – 100) mg/dm3\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Permanganate index","parameters_en":[{"name":"Range","range":"(0,5 – 100) mg/dm3"}],"search_en":"Water, Water intended for human consumption Permanganate index Titrimetric method Range PN-EN ISO 8467:2001","technique_en":"Titrimetric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"高锰酸盐指数","parameters_zh":[{"name":"范围","range":"(0,5 – 100) mg/dm3"}],"search_zh":"水、生活饮用水 高锰酸盐指数 滴定法 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"水、生活饮用水"},{"_id":"6a837952af14b9c0e7b1fc6c","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Azotany (0,10 − 250) mg/dm3","parameters":[],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Azotany (0,10 − 250) mg/dm3\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Azotany (0,10 − 250) mg/dm3\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Woda, Woda do spozycia przez ludzi Azotany (0,10 − 250) mg/dm3\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Water, Water intended for human consumption Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water, Water intended for human consumption","search_zh":"水、生活饮用水 离子色谱-电导检测法（IC-CD） PN-EN ISO 10304-1:2009+AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水、生活饮用水"},{"_id":"6a837952af14b9c0e7b1fc6d","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie bisfenolu A","parameters":[{"name":"Zakres","range":"(0,010 – 5,0) μg/dm3"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Stężenie bisfenolu A\nZakres (0,010 – 5,0) μg/dm3\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"PB-46 wydanie 3 z dnia 22.02.2024 r.","norm_bases":["PB-46 wydanie 3 z dnia 22.02.2024 r."],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie bisfenolu A\nZakres (0,010 – 5,0) μg/dm3\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) PB-46 wydanie 3 z dnia 22.02.2024 r. Woda, Woda do spozycia przez ludzi Stezenie bisfenolu A\nZakres (0,010 – 5,0) μg/dm3\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) PB-46 wydanie 3 z dnia 22.02.2024 r.","categories":["water"],"row_index":55,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Bisphenol A concentration","parameters_en":[{"name":"Range","range":"(0,010 – 5,0) μg/dm3"}],"search_en":"Water, Water intended for human consumption Bisphenol A concentration Gas chromatography with mass spectrometry detection (GC-MS) Range PB-46 wydanie 3 z dnia 22.02.2024 r.","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","test_object_en":"Water, Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,010 – 5,0) μg/dm3"}],"search_zh":"水、生活饮用水 双酚 A 浓度 气相色谱-质谱法（GC-MS） 范围 PB-46 wydanie 3 z dnia 22.02.2024 r.","technique_zh":"气相色谱-质谱法（GC-MS）","test_object_zh":"水、生活饮用水","methodology_zh":"双酚 A 浓度"},{"_id":"6a837952af14b9c0e7b1fc6e","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie 17-etynyloestradiolu (EE2)","parameters":[{"name":"Zakres","range":"(0,010 – 1,0) μg/dm3"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Stężenie 17-etynyloestradiolu (EE2)\nZakres (0,010 – 1,0) μg/dm3\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"PB-46 wydanie 3 z dnia 22.02.2024 r.","norm_bases":["PB-46 wydanie 3 z dnia 22.02.2024 r."],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie 17-etynyloestradiolu (EE2)\nZakres (0,010 – 1,0) μg/dm3\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) PB-46 wydanie 3 z dnia 22.02.2024 r. Woda, Woda do spozycia przez ludzi Stezenie 17-etynyloestradiolu (EE2)\nZakres (0,010 – 1,0) μg/dm3\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) PB-46 wydanie 3 z dnia 22.02.2024 r.","categories":["water"],"row_index":56,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,010 – 1,0) μg/dm3"}],"search_en":"Water, Water intended for human consumption Gas chromatography with mass spectrometry detection (GC-MS) Range PB-46 wydanie 3 z dnia 22.02.2024 r.","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","test_object_en":"Water, Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,010 – 1,0) μg/dm3"}],"search_zh":"水、生活饮用水 气相色谱-质谱法（GC-MS） 范围 PB-46 wydanie 3 z dnia 22.02.2024 r.","technique_zh":"气相色谱-质谱法（GC-MS）","test_object_zh":"水、生活饮用水"},{"_id":"6a837952af14b9c0e7b1fc6f","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie rtęci","parameters":[{"name":"Zakres","range":"0,05 μg/dm3 – 1,0 mg/dm3"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","techniques":["Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji"],"computed":[],"activity":"Stężenie rtęci\nZakres 0,05 μg/dm3 – 1,0 mg/dm3\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","reference":"PB-21 wydanie 8 z dnia 30.03.2026 r.","norm_bases":["PB-21 wydanie 8 z dnia 30.03.2026 r."],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie rtęci\nZakres 0,05 μg/dm3 – 1,0 mg/dm3\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji PB-21 wydanie 8 z dnia 30.03.2026 r. Woda, Woda do spozycia przez ludzi Stezenie rteci\nZakres 0,05 μg/dm3 – 1,0 mg/dm3\nMetoda absorpcyjnej spektrometrii atomowej z technika amalgamacji PB-21 wydanie 8 z dnia 30.03.2026 r.","categories":["water"],"row_index":57,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury concentration","parameters_en":[{"name":"Range","range":"0,05 μg/dm3 – 1,0 mg/dm3"}],"search_en":"Water, Water intended for human consumption Mercury concentration Atomic absorption spectrometry with amalgamation technique Range PB-21 wydanie 8 z dnia 30.03.2026 r.","technique_en":"Atomic absorption spectrometry with amalgamation technique","test_object_en":"Water, Water intended for human consumption","methodology_zh":"汞浓度","parameters_zh":[{"name":"范围","range":"0,05 μg/dm3 – 1,0 mg/dm3"}],"search_zh":"水、生活饮用水 汞浓度 原子吸收光谱法（汞齐化技术） 范围 PB-21 wydanie 8 z dnia 30.03.2026 r.","technique_zh":"原子吸收光谱法（汞齐化技术）","test_object_zh":"水、生活饮用水"},{"_id":"6a837952af14b9c0e7b1fc70","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)","parameters":[{"name":"naftalen","range":"(1 – 1000) ng/dm3"},{"name":"acenaftylen","range":"(1 – 1000) ng/dm3"},{"name":"acenaften","range":"(1 – 1000) ng/dm3"},{"name":"fluoren","range":"(1 – 1000) ng/dm3"},{"name":"fenantren","range":"(1 – 1000) ng/dm3"},{"name":"antracen","range":"(1 – 1000) ng/dm3"},{"name":"fluoranten","range":"(1 – 1000) ng/dm3"},{"name":"piren","range":"(1 – 1000) ng/dm3"},{"name":"benzo(a)antracen","range":"(1 – 1000) ng/dm3"},{"name":"chryzen","range":"(1 – 1000) ng/dm3"},{"name":"benzo(b)fluoranten","range":"(1 – 1000) ng/dm3"},{"name":"benzo(k)fluoranten","range":"(1 – 1000) ng/dm3"},{"name":"benzo(a)piren","range":"(0,17 – 1000) ng/dm3"},{"name":"indeno(1,2,3,-cd)piren","range":"(1 – 1000) ng/dm3"},{"name":"dibenzo(a,h)antracen","range":"(1 – 1000) ng/dm3"},{"name":"benzo(g,h,i)perylen","range":"(0,17 – 1000) ng/dm3"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)\nZakres:\nnaftalen (1 – 1000) ng/dm3\nacenaftylen (1 – 1000) ng/dm3\nacenaften (1 – 1000) ng/dm3\nfluoren (1 – 1000) ng/dm3\nfenantren (1 – 1000) ng/dm3\nantracen (1 – 1000) ng/dm3\nfluoranten (1 – 1000) ng/dm3\npiren (1 – 1000) ng/dm3\nbenzo(a)antracen (1 – 1000) ng/dm3\nchryzen (1 – 1000) ng/dm3\nbenzo(b)fluoranten (1 – 1000) ng/dm3\nbenzo(k)fluoranten (1 – 1000) ng/dm3\nbenzo(a)piren (0,17 – 1000) ng/dm3\nindeno(1,2,3,-cd)piren (1 – 1000) ng/dm3\ndibenzo(a,h)antracen (1 – 1000) ng/dm3\nbenzo(g,h,i)perylen (0,17 – 1000) ng/dm3\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"PB-02 wydanie 6 z dnia 22.02.2024 r.","norm_bases":["PB-02 wydanie 6 z dnia 22.02.2024 r."],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)\nZakres:\nnaftalen (1 – 1000) ng/dm3\nacenaftylen (1 – 1000) ng/dm3\nacenaften (1 – 1000) ng/dm3\nfluoren (1 – 1000) ng/dm3\nfenantren (1 – 1000) ng/dm3\nantracen (1 – 1000) ng/dm3\nfluoranten (1 – 1000) ng/dm3\npiren (1 – 1000) ng/dm3\nbenzo(a)antracen (1 – 1000) ng/dm3\nchryzen (1 – 1000) ng/dm3\nbenzo(b)fluoranten (1 – 1000) ng/dm3\nbenzo(k)fluoranten (1 – 1000) ng/dm3\nbenzo(a)piren (0,17 – 1000) ng/dm3\nindeno(1,2,3,-cd)piren (1 – 1000) ng/dm3\ndibenzo(a,h)antracen (1 – 1000) ng/dm3\nbenzo(g,h,i)perylen (0,17 – 1000) ng/dm3\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) PB-02 wydanie 6 z dnia 22.02.2024 r. Woda, Woda do spozycia przez ludzi Stezenie wielopierscieniowych weglowodorow aromatycznych (WWA)\nZakres:\nnaftalen (1 – 1000) ng/dm3\nacenaftylen (1 – 1000) ng/dm3\nacenaften (1 – 1000) ng/dm3\nfluoren (1 – 1000) ng/dm3\nfenantren (1 – 1000) ng/dm3\nantracen (1 – 1000) ng/dm3\nfluoranten (1 – 1000) ng/dm3\npiren (1 – 1000) ng/dm3\nbenzo(a)antracen (1 – 1000) ng/dm3\nchryzen (1 – 1000) ng/dm3\nbenzo(b)fluoranten (1 – 1000) ng/dm3\nbenzo(k)fluoranten (1 – 1000) ng/dm3\nbenzo(a)piren (0,17 – 1000) ng/dm3\nindeno(1,2,3,-cd)piren (1 – 1000) ng/dm3\ndibenzo(a,h)antracen (1 – 1000) ng/dm3\nbenzo(g,h,i)perylen (0,17 – 1000) ng/dm3\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) PB-02 wydanie 6 z dnia 22.02.2024 r.","categories":["water"],"row_index":58,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of polycyclic aromatic hydrocarbons (PAH)","parameters_en":[{"name":"naphthalene","range":"(1 – 1000) ng/dm3"},{"name":"acenaphthylene","range":"(1 – 1000) ng/dm3"},{"name":"acenaphthene","range":"(1 – 1000) ng/dm3"},{"name":"fluorene","range":"(1 – 1000) ng/dm3"},{"name":"phenanthrene","range":"(1 – 1000) ng/dm3"},{"name":"anthracene","range":"(1 – 1000) ng/dm3"},{"name":"fluoranthene","range":"(1 – 1000) ng/dm3"},{"name":"pyrene","range":"(1 – 1000) ng/dm3"},{"name":"benzo(a)anthracene","range":"(1 – 1000) ng/dm3"},{"name":"chrysene","range":"(1 – 1000) ng/dm3"},{"name":"benzo(b)fluoranthene","range":"(1 – 1000) ng/dm3"},{"name":"benzo(k)fluoranthene","range":"(1 – 1000) ng/dm3"},{"name":"benzo(a)pyrene","range":"(0,17 – 1000) ng/dm3"},{"name":"indeno(1,2,3,-cd)pyrene","range":"(1 – 1000) ng/dm3"},{"name":"dibenzo(a,h)anthracene","range":"(1 – 1000) ng/dm3"},{"name":"benzo(g,h,i)perylene","range":"(0,17 – 1000) ng/dm3"}],"search_en":"Water, Water intended for human consumption Concentration of polycyclic aromatic hydrocarbons (PAH) Gas chromatography with mass spectrometry detection (GC-MS) naphthalene acenaphthylene acenaphthene fluorene phenanthrene anthracene fluoranthene pyrene benzo(a)anthracene chrysene benzo(b)fluoranthene benzo(k)fluoranthene benzo(a)pyrene indeno(1,2,3,-cd)pyrene dibenzo(a,h)anthracene benzo(g,h,i)perylene PB-02 wydanie 6 z dnia 22.02.2024 r.","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","test_object_en":"Water, Water intended for human consumption","search_zh":"水、生活饮用水 多环芳烃（PAHs）浓度 气相色谱-质谱法（GC-MS） 萘 苊烯 苊 芴 菲 蒽 荧蒽 芘 苯并（a）蒽 䓛 苯并（b）荧蒽 苯并（k）荧蒽 苯并（a）芘 二苯并（a,h）蒽 苯并(g,h,i)苝 PB-02 wydanie 6 z dnia 22.02.2024 r.","technique_zh":"气相色谱-质谱法（GC-MS）","test_object_zh":"水、生活饮用水","parameters_zh":[{"name":"萘","range":"(1 – 1000) ng/dm3"},{"name":"苊烯","range":"(1 – 1000) ng/dm3"},{"name":"苊","range":"(1 – 1000) ng/dm3"},{"name":"芴","range":"(1 – 1000) ng/dm3"},{"name":"菲","range":"(1 – 1000) ng/dm3"},{"name":"蒽","range":"(1 – 1000) ng/dm3"},{"name":"荧蒽","range":"(1 – 1000) ng/dm3"},{"name":"芘","range":"(1 – 1000) ng/dm3"},{"name":"苯并（a）蒽","range":"(1 – 1000) ng/dm3"},{"name":"䓛","range":"(1 – 1000) ng/dm3"},{"name":"苯并（b）荧蒽","range":"(1 – 1000) ng/dm3"},{"name":"苯并（k）荧蒽","range":"(1 – 1000) ng/dm3"},{"name":"苯并（a）芘","range":"(0,17 – 1000) ng/dm3"},{"name":"indeno(1,2,3,-cd)piren","range":"(1 – 1000) ng/dm3"},{"name":"二苯并（a,h）蒽","range":"(1 – 1000) ng/dm3"},{"name":"苯并(g,h,i)苝","range":"(0,17 – 1000) ng/dm3"}],"methodology_zh":"多环芳烃（PAHs）浓度"},{"_id":"6a837952af14b9c0e7b1fc71","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Suma wielopierścieniowych węglowodorów aromatycznych (WWA) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma wielopierścieniowych węglowodorów aromatycznych (WWA) (z obliczeń)","reference":"I-24 wydanie 3 z dnia 26.02.2024 r.","norm_bases":["I-24 wydanie 3 z dnia 26.02.2024 r."],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Suma wielopierścieniowych węglowodorów aromatycznych (WWA) (z obliczeń) I-24 wydanie 3 z dnia 26.02.2024 r. Woda, Woda do spozycia przez ludzi Suma wielopierscieniowych weglowodorow aromatycznych (WWA) (z obliczen) I-24 wydanie 3 z dnia 26.02.2024 r.","categories":["water"],"row_index":59,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of polycyclic aromatic hydrocarbons (PAH) (calculated)","search_en":"Water, Water intended for human consumption Sum of polycyclic aromatic hydrocarbons (PAH) (calculated) I-24 wydanie 3 z dnia 26.02.2024 r.","test_object_en":"Water, Water intended for human consumption","search_zh":"水、生活饮用水 多环芳烃（PAH）总量（由计算得出） I-24 wydanie 3 z dnia 26.02.2024 r.","test_object_zh":"水、生活饮用水","methodology_zh":"多环芳烃（PAH）总量（由计算得出）"},{"_id":"6a837952af14b9c0e7b1fc72","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Suma węglowodorów alifatycznych i aromatycznych C6 – C12 (suma benzyn)","parameters":[{"name":"Zakres","range":"(1 – 200) μg/dm3"}],"technique":"Metoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją płomieniowo-jonizacyjną (P&T GC-FID)","techniques":["Metoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją płomieniowo-jonizacyjną (P&T GC-FID)"],"computed":[],"activity":"Suma węglowodorów alifatycznych i aromatycznych C6 – C12 (suma benzyn)\nZakres (1 – 200) μg/dm3\nMetoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją płomieniowo-jonizacyjną (P&T GC-FID)","reference":"PB-12 wydanie nr 11 z 22.02.2024 r.","norm_bases":["PB-12 wydanie nr 11 z 22.02.2024 r."],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Suma węglowodorów alifatycznych i aromatycznych C6 – C12 (suma benzyn)\nZakres (1 – 200) μg/dm3\nMetoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją płomieniowo-jonizacyjną (P&T GC-FID) PB-12 wydanie nr 11 z 22.02.2024 r. Woda, Woda do spozycia przez ludzi Suma weglowodorow alifatycznych i aromatycznych C6 – C12 (suma benzyn)\nZakres (1 – 200) μg/dm3\nMetoda chromatografii gazowej z technika wylapywania i wyplukiwania (Purge&Trap) i detekcja plomieniowo-jonizacyjna (P&T GC-FID) PB-12 wydanie nr 11 z 22.02.2024 r.","categories":["water"],"row_index":60,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of aliphatic and aromatic hydrocarbons C6 – C12 (sum of gasolines)","parameters_en":[{"name":"Range","range":"(1 – 200) μg/dm3"}],"search_en":"Water, Water intended for human consumption Sum of aliphatic and aromatic hydrocarbons C6 – C12 (sum of gasolines) Gas chromatography with purge and trap technique (Purge&Trap) and flame ionization detection (P&T GC-FID) Range PB-12 wydanie nr 11 z 22.02.2024 r.","technique_en":"Gas chromatography with purge and trap technique (Purge&Trap) and flame ionization detection (P&T GC-FID)","test_object_en":"Water, Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(1 – 200) μg/dm3"}],"search_zh":"水、生活饮用水 范围 PB-12 wydanie nr 11 z 22.02.2024 r.","test_object_zh":"水、生活饮用水"},{"_id":"6a837952af14b9c0e7b1fc73","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Suma węglowodorów C6 – C40 (suma benzyn i oleju mineralnego) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma węglowodorów C6 – C40 (suma benzyn i oleju mineralnego) (z obliczeń)","reference":"I-24 wydanie 3 z dnia 26.02.2024 r.","norm_bases":["I-24 wydanie 3 z dnia 26.02.2024 r."],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Suma węglowodorów C6 – C40 (suma benzyn i oleju mineralnego) (z obliczeń) I-24 wydanie 3 z dnia 26.02.2024 r. Woda, Woda do spozycia przez ludzi Suma weglowodorow C6 – C40 (suma benzyn i oleju mineralnego) (z obliczen) I-24 wydanie 3 z dnia 26.02.2024 r.","categories":["water","petro"],"row_index":61,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of hydrocarbons C6 – C40 (sum of gasolines and mineral oil) (calculated)","search_en":"Water, Water intended for human consumption Sum of hydrocarbons C6 – C40 (sum of gasolines and mineral oil) (calculated) I-24 wydanie 3 z dnia 26.02.2024 r.","test_object_en":"Water, Water intended for human consumption","search_zh":"水、生活饮用水 I-24 wydanie 3 z dnia 26.02.2024 r.","test_object_zh":"水、生活饮用水"},{"_id":"6a837952af14b9c0e7b1fc74","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie chromu (VI)","parameters":[{"name":"Zakres","range":"(0,005 – 0,200) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chromu (VI)\nZakres (0,005 – 0,200) mg/dm3\nMetoda spektrofotometryczna","reference":"PN-EN ISO 18412:2007","norm_bases":["PN-EN ISO 18412:2007"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie chromu (VI)\nZakres (0,005 – 0,200) mg/dm3\nMetoda spektrofotometryczna PN-EN ISO 18412:2007 Woda, Woda do spozycia przez ludzi Stezenie chromu (VI)\nZakres (0,005 – 0,200) mg/dm3\nMetoda spektrofotometryczna PN-EN ISO 18412:2007","categories":["water"],"row_index":62,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chromium(VI) concentration","parameters_en":[{"name":"Range","range":"(0,005 – 0,200) mg/dm3"}],"search_en":"Water, Water intended for human consumption Chromium(VI) concentration Spectrophotometric method Range PN-EN ISO 18412:2007","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,005 – 0,200) mg/dm3"}],"search_zh":"水、生活饮用水 六价铬浓度 分光光度法 范围 PN-EN ISO 18412:2007","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","methodology_zh":"六价铬浓度"},{"_id":"6a837952af14b9c0e7b1fc75","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie azotu ogólnego","parameters":[{"name":"Zakres","range":"(0,5 – 150) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu ogólnego\nZakres (0,5 – 150) mg/dm3\nMetoda spektrofotometryczna","reference":"PB-03 wydanie 6 z dnia 22.02.2024 r. Na podstawie testu kuwetowego nr 1.14537 i 1.14763 MERCK","norm_bases":["PB-03 wydanie 6 z dnia 22.02.2024 r. Na podstawie testu kuwetowego nr 1.14537 i 1.14763 MERCK"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie azotu ogólnego\nZakres (0,5 – 150) mg/dm3\nMetoda spektrofotometryczna PB-03 wydanie 6 z dnia 22.02.2024 r. Na podstawie testu kuwetowego nr 1.14537 i 1.14763 MERCK Woda Stezenie azotu ogolnego\nZakres (0,5 – 150) mg/dm3\nMetoda spektrofotometryczna PB-03 wydanie 6 z dnia 22.02.2024 r. Na podstawie testu kuwetowego nr 1.14537 i 1.14763 MERCK","categories":["water"],"row_index":63,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,5 – 150) mg/dm3"}],"search_en":"Water Total nitrogen concentration Spectrophotometric method Range PB-03 wydanie 6 z dnia 22.02.2024 r. Na podstawie testu kuwetowego nr 1.14537 i 1.14763 MERCK","technique_en":"Spectrophotometric method","test_object_en":"Water","methodology_zh":"总氮浓度","parameters_zh":[{"name":"范围","range":"(0,5 – 150) mg/dm3"}],"search_zh":"水 总氮浓度 分光光度法 范围 PB-03 wydanie 6 z dnia 22.02.2024 r. Na podstawie testu kuwetowego nr 1.14537 i 1.14763 MERCK","technique_zh":"分光光度法","test_object_zh":"水"},{"_id":"6a837952af14b9c0e7b1fc76","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie azotu ogólnego","parameters":[{"name":"Zakres","range":"(0,5 – 700) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu ogólnego\nZakres (0,5 – 700) mg/dm3\nMetoda spektrofotometryczna","reference":"PB-03 wydanie 6 z dnia 22.02.2024 r. Na podstawie testu kuwetowego nr 1.14537 i 1.14763 MERCK","norm_bases":["PB-03 wydanie 6 z dnia 22.02.2024 r. Na podstawie testu kuwetowego nr 1.14537 i 1.14763 MERCK"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie azotu ogólnego\nZakres (0,5 – 700) mg/dm3\nMetoda spektrofotometryczna PB-03 wydanie 6 z dnia 22.02.2024 r. Na podstawie testu kuwetowego nr 1.14537 i 1.14763 MERCK Woda Stezenie azotu ogolnego\nZakres (0,5 – 700) mg/dm3\nMetoda spektrofotometryczna PB-03 wydanie 6 z dnia 22.02.2024 r. Na podstawie testu kuwetowego nr 1.14537 i 1.14763 MERCK","categories":["water"],"row_index":64,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,5 – 700) mg/dm3"}],"search_en":"Water Total nitrogen concentration Spectrophotometric method Range PB-03 wydanie 6 z dnia 22.02.2024 r. Na podstawie testu kuwetowego nr 1.14537 i 1.14763 MERCK","technique_en":"Spectrophotometric method","test_object_en":"Water","methodology_zh":"总氮浓度","parameters_zh":[{"name":"范围","range":"(0,5 – 700) mg/dm3"}],"search_zh":"水 总氮浓度 分光光度法 范围 PB-03 wydanie 6 z dnia 22.02.2024 r. Na podstawie testu kuwetowego nr 1.14537 i 1.14763 MERCK","technique_zh":"分光光度法","test_object_zh":"水"},{"_id":"6a837952af14b9c0e7b1fc77","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Substancje rozpuszczone","parameters":[{"name":"Zakres","range":"(1,00 – 10 000) mg/dm3"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Substancje rozpuszczone\nZakres (1,00 – 10 000) mg/dm3\nMetoda wagowa","reference":"PB-13 wydanie 5 z dnia 22.02.2024 r.","norm_bases":["PB-13 wydanie 5 z dnia 22.02.2024 r."],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Substancje rozpuszczone\nZakres (1,00 – 10 000) mg/dm3\nMetoda wagowa PB-13 wydanie 5 z dnia 22.02.2024 r. Woda, Scieki Substancje rozpuszczone\nZakres (1,00 – 10 000) mg/dm3\nMetoda wagowa PB-13 wydanie 5 z dnia 22.02.2024 r.","categories":["water"],"row_index":65,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissolved solids","parameters_en":[{"name":"Range","range":"(1,00 – 10 000) mg/dm3"}],"search_en":"Water, Wastewater Dissolved solids Gravimetric method Range PB-13 wydanie 5 z dnia 22.02.2024 r.","technique_en":"Gravimetric method","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(1,00 – 10 000) mg/dm3"}],"search_zh":"水、污水 溶解性固体 重量法 范围 PB-13 wydanie 5 z dnia 22.02.2024 r.","technique_zh":"重量法","test_object_zh":"水、污水","methodology_zh":"溶解性固体"},{"_id":"6a837952af14b9c0e7b1fc78","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Sucha pozostałość w temp. 105°C i 180°C","parameters":[{"name":"Zakres","range":"(10,0 – 10000) mg/dm3"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha pozostałość w temp. 105°C i 180°C\nZakres (10,0 – 10000) mg/dm3\nMetoda wagowa","reference":"PB-13 wydanie 5 z dnia 22.02.2024 r.","norm_bases":["PB-13 wydanie 5 z dnia 22.02.2024 r."],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Sucha pozostałość w temp. 105°C i 180°C\nZakres (10,0 – 10000) mg/dm3\nMetoda wagowa PB-13 wydanie 5 z dnia 22.02.2024 r. Woda, Scieki Sucha pozostalosc w temp. 105°C i 180°C\nZakres (10,0 – 10000) mg/dm3\nMetoda wagowa PB-13 wydanie 5 z dnia 22.02.2024 r.","categories":["water"],"row_index":66,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry residue at 105°C and 180°C","parameters_en":[{"name":"Range","range":"(10,0 – 10000) mg/dm3"}],"search_en":"Water, Wastewater Dry residue at 105°C and 180°C Gravimetric method Range PB-13 wydanie 5 z dnia 22.02.2024 r.","technique_en":"Gravimetric method","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(10,0 – 10000) mg/dm3"}],"search_zh":"水、污水 重量法 范围 PB-13 wydanie 5 z dnia 22.02.2024 r.","technique_zh":"重量法","test_object_zh":"水、污水"},{"_id":"6a837952af14b9c0e7b1fc79","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5,0 – 5000) mg/dm3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5,0 – 5000) mg/dm3\nMetoda miareczkowa","reference":"PN-EN ISO 9297:1994","norm_bases":["PN-EN ISO 9297:1994"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie chlorków\nZakres (5,0 – 5000) mg/dm3\nMetoda miareczkowa PN-EN ISO 9297:1994 Woda, Scieki Stezenie chlorkow\nZakres (5,0 – 5000) mg/dm3\nMetoda miareczkowa PN-EN ISO 9297:1994","categories":["water"],"row_index":67,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5,0 – 5000) mg/dm3"}],"search_en":"Water, Wastewater Chloride concentration Titrimetric method Range PN-EN ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Water, Wastewater","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,0 – 5000) mg/dm3"}],"search_zh":"水、污水 氯化物浓度 滴定法 范围 PN-EN ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水、污水"},{"_id":"6a837952af14b9c0e7b1fc7a","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(5 – 1000) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie siarczanów\nZakres (5 – 1000) mg/dm3\nMetoda spektrofotometryczna","reference":"PB–08 wydanie 7 z dnia 22.02.2024 r. | na podstawie testu kuwetowego nr 1.14548 MERCK","norm_bases":["PB–08 wydanie 7 z dnia 22.02.2024 r.","na podstawie testu kuwetowego nr 1.14548 MERCK"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie siarczanów\nZakres (5 – 1000) mg/dm3\nMetoda spektrofotometryczna PB–08 wydanie 7 z dnia 22.02.2024 r. | na podstawie testu kuwetowego nr 1.14548 MERCK Woda, Scieki Stezenie siarczanow\nZakres (5 – 1000) mg/dm3\nMetoda spektrofotometryczna PB–08 wydanie 7 z dnia 22.02.2024 r. | na podstawie testu kuwetowego nr 1.14548 MERCK","categories":["water"],"row_index":68,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Range","range":"(5 – 1000) mg/dm3"}],"search_en":"Water, Wastewater Sulfate concentration Spectrophotometric method Range PB–08 wydanie 7 z dnia 22.02.2024 r. | na podstawie testu kuwetowego nr 1.14548 MERCK","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(5 – 1000) mg/dm3"}],"search_zh":"水、污水 硫酸盐浓度 分光光度法 范围 PB–08 wydanie 7 z dnia 22.02.2024 r. | na podstawie testu kuwetowego nr 1.14548 MERCK","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a837952af14b9c0e7b1fc7b","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie fosforanów","parameters":[{"name":"Zakres","range":"(0,03 – 40) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforanów\nZakres (0,03 – 40) mg/dm3\nMetoda spektrofotometryczna","reference":"PB-07 wydanie 6 z dnia 22.02.2024 r. Na podstawie testu kuwetowego nr 1.14848 MERCK","norm_bases":["PB-07 wydanie 6 z dnia 22.02.2024 r. Na podstawie testu kuwetowego nr 1.14848 MERCK"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie fosforanów\nZakres (0,03 – 40) mg/dm3\nMetoda spektrofotometryczna PB-07 wydanie 6 z dnia 22.02.2024 r. Na podstawie testu kuwetowego nr 1.14848 MERCK Woda, Scieki Stezenie fosforanow\nZakres (0,03 – 40) mg/dm3\nMetoda spektrofotometryczna PB-07 wydanie 6 z dnia 22.02.2024 r. Na podstawie testu kuwetowego nr 1.14848 MERCK","categories":["water"],"row_index":69,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phosphate concentration","parameters_en":[{"name":"Range","range":"(0,03 – 40) mg/dm3"}],"search_en":"Water, Wastewater Phosphate concentration Spectrophotometric method Range PB-07 wydanie 6 z dnia 22.02.2024 r. Na podstawie testu kuwetowego nr 1.14848 MERCK","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(0,03 – 40) mg/dm3"}],"search_zh":"水、污水 磷酸盐浓度 分光光度法 范围 PB-07 wydanie 6 z dnia 22.02.2024 r. Na podstawie testu kuwetowego nr 1.14848 MERCK","technique_zh":"分光光度法","test_object_zh":"水、污水","methodology_zh":"磷酸盐浓度"},{"_id":"6a837952af14b9c0e7b1fc7c","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,05 – 50,0) mg /dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,05 – 50,0) mg /dm3\nMetoda spektrofotometryczna","reference":"PB-20 wydanie 5 z dnia 22.02.2024 r. Na podstawie testu kuwetowego nr 1.14543 MERCK","norm_bases":["PB-20 wydanie 5 z dnia 22.02.2024 r. Na podstawie testu kuwetowego nr 1.14543 MERCK"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie fosforu ogólnego\nZakres (0,05 – 50,0) mg /dm3\nMetoda spektrofotometryczna PB-20 wydanie 5 z dnia 22.02.2024 r. Na podstawie testu kuwetowego nr 1.14543 MERCK Woda, Scieki Stezenie fosforu ogolnego\nZakres (0,05 – 50,0) mg /dm3\nMetoda spektrofotometryczna PB-20 wydanie 5 z dnia 22.02.2024 r. Na podstawie testu kuwetowego nr 1.14543 MERCK","categories":["water"],"row_index":70,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,05 – 50,0) mg /dm3"}],"search_en":"Water, Wastewater Total phosphorus concentration Spectrophotometric method Range PB-20 wydanie 5 z dnia 22.02.2024 r. Na podstawie testu kuwetowego nr 1.14543 MERCK","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,05 – 50,0) mg /dm3"}],"search_zh":"水、污水 总磷浓度 分光光度法 范围 PB-20 wydanie 5 z dnia 22.02.2024 r. Na podstawie testu kuwetowego nr 1.14543 MERCK","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a837952af14b9c0e7b1fc7d","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie azotu azotanowego","parameters":[{"name":"Zakres","range":"(0,2 – 20) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotanowego\nZakres (0,2 – 20) mg/dm3\nMetoda spektrofotometryczna","reference":"PB-04 wydanie 6 z dnia 22.02.2024 r. Na podstawie testu kuwetowego nr 1.14773 MERCK","norm_bases":["PB-04 wydanie 6 z dnia 22.02.2024 r. Na podstawie testu kuwetowego nr 1.14773 MERCK"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie azotu azotanowego\nZakres (0,2 – 20) mg/dm3\nMetoda spektrofotometryczna PB-04 wydanie 6 z dnia 22.02.2024 r. Na podstawie testu kuwetowego nr 1.14773 MERCK Woda, Scieki Stezenie azotu azotanowego\nZakres (0,2 – 20) mg/dm3\nMetoda spektrofotometryczna PB-04 wydanie 6 z dnia 22.02.2024 r. Na podstawie testu kuwetowego nr 1.14773 MERCK","categories":["water"],"row_index":71,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,2 – 20) mg/dm3"}],"search_en":"Water, Wastewater Nitrate nitrogen concentration Spectrophotometric method Range PB-04 wydanie 6 z dnia 22.02.2024 r. Na podstawie testu kuwetowego nr 1.14773 MERCK","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,2 – 20) mg/dm3"}],"search_zh":"水、污水 硝态氮浓度 分光光度法 范围 PB-04 wydanie 6 z dnia 22.02.2024 r. Na podstawie testu kuwetowego nr 1.14773 MERCK","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a837952af14b9c0e7b1fc7e","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,002 – 1,00) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres (0,002 – 1,00) mg/dm3\nMetoda spektrofotometryczna","reference":"PB-05 wydanie 6 z dnia 22.02.2024 r. Na podstawie testu kuwetowego nr 1.14776 MERCK","norm_bases":["PB-05 wydanie 6 z dnia 22.02.2024 r. Na podstawie testu kuwetowego nr 1.14776 MERCK"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie azotu azotynowego\nZakres (0,002 – 1,00) mg/dm3\nMetoda spektrofotometryczna PB-05 wydanie 6 z dnia 22.02.2024 r. Na podstawie testu kuwetowego nr 1.14776 MERCK Woda, Scieki Stezenie azotu azotynowego\nZakres (0,002 – 1,00) mg/dm3\nMetoda spektrofotometryczna PB-05 wydanie 6 z dnia 22.02.2024 r. Na podstawie testu kuwetowego nr 1.14776 MERCK","categories":["water"],"row_index":72,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,002 – 1,00) mg/dm3"}],"search_en":"Water, Wastewater Nitrite nitrogen concentration Spectrophotometric method Range PB-05 wydanie 6 z dnia 22.02.2024 r. Na podstawie testu kuwetowego nr 1.14776 MERCK","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,002 – 1,00) mg/dm3"}],"search_zh":"水、污水 亚硝态氮浓度 分光光度法 范围 PB-05 wydanie 6 z dnia 22.02.2024 r. Na podstawie testu kuwetowego nr 1.14776 MERCK","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a837952af14b9c0e7b1fc7f","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie siarczków","parameters":[{"name":"Zakres","range":"(0,05 − 1,5) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie siarczków\nZakres (0,05 − 1,5) mg/dm3\nMetoda spektrofotometryczna","reference":"PB-17 wydanie 5 z dnia 22.02.2024 r. Na podstawie testu kuwetowego nr 1.14779 MERCK","norm_bases":["PB-17 wydanie 5 z dnia 22.02.2024 r. Na podstawie testu kuwetowego nr 1.14779 MERCK"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie siarczków\nZakres (0,05 − 1,5) mg/dm3\nMetoda spektrofotometryczna PB-17 wydanie 5 z dnia 22.02.2024 r. Na podstawie testu kuwetowego nr 1.14779 MERCK Woda, Scieki Stezenie siarczkow\nZakres (0,05 − 1,5) mg/dm3\nMetoda spektrofotometryczna PB-17 wydanie 5 z dnia 22.02.2024 r. Na podstawie testu kuwetowego nr 1.14779 MERCK","categories":["water"],"row_index":73,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfide concentration","parameters_en":[{"name":"Range","range":"(0,05 − 1,5) mg/dm3"}],"search_en":"Water, Wastewater Sulfide concentration Spectrophotometric method Range PB-17 wydanie 5 z dnia 22.02.2024 r. Na podstawie testu kuwetowego nr 1.14779 MERCK","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(0,05 − 1,5) mg/dm3"}],"search_zh":"水、污水 硫化物浓度 分光光度法 范围 PB-17 wydanie 5 z dnia 22.02.2024 r. Na podstawie testu kuwetowego nr 1.14779 MERCK","technique_zh":"分光光度法","test_object_zh":"水、污水","methodology_zh":"硫化物浓度"},{"_id":"6a837952af14b9c0e7b1fc80","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki, Wody opadowe i roztopowe","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(50 – 50 000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (50 – 50 000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki, Wody opadowe i roztopowe Przewodność elektryczna właściwa\nZakres (50 – 50 000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, Woda do spozycia przez ludzi, Scieki, Wody opadowe i roztopowe Przewodnosc elektryczna wlasciwa\nZakres (50 – 50 000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":74,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(50 – 50 000) μS/cm"}],"search_en":"Water, Water intended for human consumption, Wastewater, Rainwater and snowmelt water Electrical conductivity Conductometric method Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water, Water intended for human consumption, Wastewater, Rainwater and snowmelt water","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(50 – 50 000) μS/cm"}],"search_zh":"水、生活饮用水、废水、雨水与融雪水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、生活饮用水、废水、雨水与融雪水"},{"_id":"6a837952af14b9c0e7b1fc81","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki, Wody opadowe i roztopowe","methodology":"Indeks oleju mineralnego","parameters":[{"name":"Zakres","range":"(0,01 – 50) mg/dm3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Indeks oleju mineralnego\nZakres (0,01 – 50) mg/dm3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN ISO 9377-2:2003","norm_bases":["PN-EN ISO 9377-2:2003"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki, Wody opadowe i roztopowe Indeks oleju mineralnego\nZakres (0,01 – 50) mg/dm3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN ISO 9377-2:2003 Woda, Woda do spozycia przez ludzi, Scieki, Wody opadowe i roztopowe Indeks oleju mineralnego\nZakres (0,01 – 50) mg/dm3\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN ISO 9377-2:2003","categories":["water","petro"],"row_index":75,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mineral oil index","parameters_en":[{"name":"Range","range":"(0,01 – 50) mg/dm3"}],"search_en":"Water, Water intended for human consumption, Wastewater, Rainwater and snowmelt water Mineral oil index Gas chromatography with flame ionization detection (GC-FID) Range PN-EN ISO 9377-2:2003","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Water, Water intended for human consumption, Wastewater, Rainwater and snowmelt water","parameters_zh":[{"name":"范围","range":"(0,01 – 50) mg/dm3"}],"search_zh":"水、生活饮用水、废水、雨水与融雪水 矿物油指数 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-EN ISO 9377-2:2003","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","methodology_zh":"矿物油指数","test_object_zh":"水、生活饮用水、废水、雨水与融雪水"},{"_id":"6a837952af14b9c0e7b1fc82","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki, Wody opadowe i roztopowe","methodology":"Biochemiczne zapotrzebowanie tlenu","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(0,50 – 3,00) mg/dm3 O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,50 – 3,00) mg/dm3 O2\nMetoda miareczkowa","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki, Wody opadowe i roztopowe Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,50 – 3,00) mg/dm3 O2\nMetoda miareczkowa PN-EN 1899-2:2002 Woda, Woda do spozycia przez ludzi, Scieki, Wody opadowe i roztopowe Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,50 – 3,00) mg/dm3 O2\nMetoda miareczkowa PN-EN 1899-2:2002","categories":["water"],"row_index":76,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand","parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(0,50 – 3,00) mg/dm3 O2"}],"search_en":"Water, Water intended for human consumption, Wastewater, Rainwater and snowmelt water Biochemical oxygen demand Titrimetric method BOD5 Range PN-EN 1899-2:2002","technique_en":"Titrimetric method","test_object_en":"Water, Water intended for human consumption, Wastewater, Rainwater and snowmelt water","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(0,50 – 3,00) mg/dm3 O2"}],"search_zh":"水、生活饮用水、废水、雨水与融雪水 生化需氧量 滴定法 BZT5（BOD5） 范围 PN-EN 1899-2:2002","technique_zh":"滴定法","test_object_zh":"水、生活饮用水、废水、雨水与融雪水"},{"_id":"6a837952af14b9c0e7b1fc83","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki, Wody opadowe i roztopowe","methodology":"Biochemiczne zapotrzebowanie tlenu","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(2,00 – 2100) mg/dm3 O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (2,00 – 2100) mg/dm3 O2\nMetoda miareczkowa","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki, Wody opadowe i roztopowe Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (2,00 – 2100) mg/dm3 O2\nMetoda miareczkowa PN-EN ISO 5815-1:2019-12 Woda, Woda do spozycia przez ludzi, Scieki, Wody opadowe i roztopowe Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (2,00 – 2100) mg/dm3 O2\nMetoda miareczkowa PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":77,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand","parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(2,00 – 2100) mg/dm3 O2"}],"search_en":"Water, Water intended for human consumption, Wastewater, Rainwater and snowmelt water Biochemical oxygen demand Titrimetric method BOD5 Range PN-EN ISO 5815-1:2019-12","technique_en":"Titrimetric method","test_object_en":"Water, Water intended for human consumption, Wastewater, Rainwater and snowmelt water","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(2,00 – 2100) mg/dm3 O2"}],"search_zh":"水、生活饮用水、废水、雨水与融雪水 生化需氧量 滴定法 BZT5（BOD5） 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"滴定法","test_object_zh":"水、生活饮用水、废水、雨水与融雪水"},{"_id":"6a837952af14b9c0e7b1fc84","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki, Wody opadowe i roztopowe","methodology":"Biochemiczne zapotrzebowanie tlenu","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(0,50 – 3,00) mg/dm3 O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,50 – 3,00) mg/dm3 O2\nMetoda optyczna","reference":"PN-EN 1899-2:2002 ISO 17289:2014","norm_bases":["PN-EN 1899-2:2002 ISO 17289:2014"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki, Wody opadowe i roztopowe Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,50 – 3,00) mg/dm3 O2\nMetoda optyczna PN-EN 1899-2:2002 ISO 17289:2014 Woda, Woda do spozycia przez ludzi, Scieki, Wody opadowe i roztopowe Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,50 – 3,00) mg/dm3 O2\nMetoda optyczna PN-EN 1899-2:2002 ISO 17289:2014","categories":["water"],"row_index":78,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand","parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(0,50 – 3,00) mg/dm3 O2"}],"search_en":"Water, Water intended for human consumption, Wastewater, Rainwater and snowmelt water Biochemical oxygen demand Optical method BOD5 Range PN-EN 1899-2:2002 ISO 17289:2014","technique_en":"Optical method","test_object_en":"Water, Water intended for human consumption, Wastewater, Rainwater and snowmelt water","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(0,50 – 3,00) mg/dm3 O2"}],"search_zh":"水、生活饮用水、废水、雨水与融雪水 生化需氧量 光学法 BZT5（BOD5） 范围 PN-EN 1899-2:2002 ISO 17289:2014","technique_zh":"光学法","test_object_zh":"水、生活饮用水、废水、雨水与融雪水"},{"_id":"6a837952af14b9c0e7b1fc85","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki, Wody opadowe i roztopowe","methodology":"Biochemiczne zapotrzebowanie tlenu","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(2, 00 – 2100) mg/dm3 O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (2, 00 – 2100) mg/dm3 O2\nMetoda optyczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki, Wody opadowe i roztopowe Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (2, 00 – 2100) mg/dm3 O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12 Woda, Woda do spozycia przez ludzi, Scieki, Wody opadowe i roztopowe Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (2, 00 – 2100) mg/dm3 O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":79,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand","parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(2, 00 – 2100) mg/dm3 O2"}],"search_en":"Water, Water intended for human consumption, Wastewater, Rainwater and snowmelt water Biochemical oxygen demand Optical method BOD5 Range PN-EN ISO 5815-1:2019-12","technique_en":"Optical method","test_object_en":"Water, Water intended for human consumption, Wastewater, Rainwater and snowmelt water","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(2, 00 – 2100) mg/dm3 O2"}],"search_zh":"水、生活饮用水、废水、雨水与融雪水 生化需氧量 光学法 BZT5（BOD5） 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"光学法","test_object_zh":"水、生活饮用水、废水、雨水与融雪水"},{"_id":"6a837952af14b9c0e7b1fc86","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki, Wody opadowe i roztopowe","methodology":"Stężenie tlenu rozpuszczonego","parameters":[{"name":"Zakres","range":"(0,50 − 15,0) mg/dm3 O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie tlenu rozpuszczonego\nZakres (0,50 − 15,0) mg/dm3 O2\nMetoda miareczkowa","reference":"PN-EN 25813:1997","norm_bases":["PN-EN 25813:1997"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki, Wody opadowe i roztopowe Stężenie tlenu rozpuszczonego\nZakres (0,50 − 15,0) mg/dm3 O2\nMetoda miareczkowa PN-EN 25813:1997 Woda, Woda do spozycia przez ludzi, Scieki, Wody opadowe i roztopowe Stezenie tlenu rozpuszczonego\nZakres (0,50 − 15,0) mg/dm3 O2\nMetoda miareczkowa PN-EN 25813:1997","categories":["water"],"row_index":80,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissolved oxygen concentration","parameters_en":[{"name":"Range","range":"(0,50 − 15,0) mg/dm3 O2"}],"search_en":"Water, Water intended for human consumption, Wastewater, Rainwater and snowmelt water Dissolved oxygen concentration Titrimetric method Range PN-EN 25813:1997","technique_en":"Titrimetric method","test_object_en":"Water, Water intended for human consumption, Wastewater, Rainwater and snowmelt water","parameters_zh":[{"name":"范围","range":"(0,50 − 15,0) mg/dm3 O2"}],"search_zh":"水、生活饮用水、废水、雨水与融雪水 溶解氧浓度 滴定法 范围 PN-EN 25813:1997","technique_zh":"滴定法","methodology_zh":"溶解氧浓度","test_object_zh":"水、生活饮用水、废水、雨水与融雪水"},{"_id":"6a837952af14b9c0e7b1fc87","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki, Wody opadowe i roztopowe","methodology":"Stężenie tlenu rozpuszczonego","parameters":[{"name":"Zakres","range":"(0,5 − 20) mg/dm3 O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Stężenie tlenu rozpuszczonego\nZakres (0,5 − 20) mg/dm3 O2\nMetoda optyczna","reference":"ISO 17289:2014","norm_bases":["ISO 17289:2014"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki, Wody opadowe i roztopowe Stężenie tlenu rozpuszczonego\nZakres (0,5 − 20) mg/dm3 O2\nMetoda optyczna ISO 17289:2014 Woda, Woda do spozycia przez ludzi, Scieki, Wody opadowe i roztopowe Stezenie tlenu rozpuszczonego\nZakres (0,5 − 20) mg/dm3 O2\nMetoda optyczna ISO 17289:2014","categories":["water"],"row_index":81,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissolved oxygen concentration","parameters_en":[{"name":"Range","range":"(0,5 − 20) mg/dm3 O2"}],"search_en":"Water, Water intended for human consumption, Wastewater, Rainwater and snowmelt water Dissolved oxygen concentration Optical method Range ISO 17289:2014","technique_en":"Optical method","test_object_en":"Water, Water intended for human consumption, Wastewater, Rainwater and snowmelt water","parameters_zh":[{"name":"范围","range":"(0,5 − 20) mg/dm3 O2"}],"search_zh":"水、生活饮用水、废水、雨水与融雪水 溶解氧浓度 光学法 范围 ISO 17289:2014","technique_zh":"光学法","methodology_zh":"溶解氧浓度","test_object_zh":"水、生活饮用水、废水、雨水与融雪水"},{"_id":"6a837952af14b9c0e7b1fc88","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki, Wody opadowe i roztopowe","methodology":"Zasadowość / wodorowęglany","parameters":[{"name":"Zakres","range":"(0,40 − 20) mmol/dm3"},{"name":"(0,40 − 20) mval/dm3"},{"name":"(20 − 1000) mg/dm3 CaCO3"},{"name":"Wodorowęglany"},{"name":"Zakres","range":"(24,4 − 1220) mg/dm3 HCO3 ̅"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zasadowość / wodorowęglany\nZakres:\nZakres (0,40 − 20) mmol/dm3\n(0,40 − 20) mval/dm3\n(20 − 1000) mg/dm3 CaCO3\nWodorowęglany\nZakres (24,4 − 1220) mg/dm3 HCO3 ̅\nMetoda miareczkowa","reference":"PN-EN ISO 9963-1:2001+Ap1:2004","norm_bases":["PN-EN ISO 9963-1:2001+Ap1:2004"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki, Wody opadowe i roztopowe Zasadowość / wodorowęglany\nZakres:\nZakres (0,40 − 20) mmol/dm3\n(0,40 − 20) mval/dm3\n(20 − 1000) mg/dm3 CaCO3\nWodorowęglany\nZakres (24,4 − 1220) mg/dm3 HCO3 ̅\nMetoda miareczkowa PN-EN ISO 9963-1:2001+Ap1:2004 Woda, Woda do spozycia przez ludzi, Scieki, Wody opadowe i roztopowe Zasadowosc / wodoroweglany\nZakres:\nZakres (0,40 − 20) mmol/dm3\n(0,40 − 20) mval/dm3\n(20 − 1000) mg/dm3 CaCO3\nWodoroweglany\nZakres (24,4 − 1220) mg/dm3 HCO3 \nMetoda miareczkowa PN-EN ISO 9963-1:2001+Ap1:2004","categories":["water"],"row_index":82,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Alkalinity / hydrogen carbonates","parameters_en":[{"name":"Range","range":"(0,40 − 20) mmol/dm3"},{"name":"(0,40 − 20) mval/dm3"},{"name":"(20 − 1000) mg/dm3 CaCO3"},{"name":"Bicarbonates"},{"name":"Range","range":"(24,4 − 1220) mg/dm3 HCO3 ̅"}],"search_en":"Water, Water intended for human consumption, Wastewater, Rainwater and snowmelt water Alkalinity / hydrogen carbonates Titrimetric method Range (0,40 − 20) mval/dm3 (20 − 1000) mg/dm3 CaCO3 Bicarbonates Range PN-EN ISO 9963-1:2001+Ap1:2004","technique_en":"Titrimetric method","test_object_en":"Water, Water intended for human consumption, Wastewater, Rainwater and snowmelt water","parameters_zh":[{"name":"范围","range":"(0,40 − 20) mmol/dm3"},{"name":"(0,40 − 20) mval/dm3"},{"name":"(20 − 1000) mg/dm3 CaCO3"},{"name":"碳酸氢盐"},{"name":"范围","range":"(24,4 − 1220) mg/dm3 HCO3 ̅"}],"search_zh":"水、生活饮用水、废水、雨水与融雪水 滴定法 范围 碳酸氢盐 范围 PN-EN ISO 9963-1:2001+Ap1:2004","technique_zh":"滴定法","test_object_zh":"水、生活饮用水、废水、雨水与融雪水"},{"_id":"6a837952af14b9c0e7b1fc89","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki, Wody opadowe i roztopowe","methodology":"Zasadowość alkaliczna (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zasadowość alkaliczna (z obliczeń)","reference":"I-23 wydanie 2 z dnia 26.02.2024 r.","norm_bases":["I-23 wydanie 2 z dnia 26.02.2024 r."],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki, Wody opadowe i roztopowe Zasadowość alkaliczna (z obliczeń) I-23 wydanie 2 z dnia 26.02.2024 r. Woda, Woda do spozycia przez ludzi, Scieki, Wody opadowe i roztopowe Zasadowosc alkaliczna (z obliczen) I-23 wydanie 2 z dnia 26.02.2024 r.","categories":["water"],"row_index":83,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Alkaline alkalinity (calculated)","search_en":"Water, Water intended for human consumption, Wastewater, Rainwater and snowmelt water Alkaline alkalinity (calculated) I-23 wydanie 2 z dnia 26.02.2024 r.","test_object_en":"Water, Water intended for human consumption, Wastewater, Rainwater and snowmelt water","search_zh":"水、生活饮用水、废水、雨水与融雪水 苛性碱度（由计算得出） I-23 wydanie 2 z dnia 26.02.2024 r.","test_object_zh":"水、生活饮用水、废水、雨水与融雪水","methodology_zh":"苛性碱度（由计算得出）"},{"_id":"6a837952af14b9c0e7b1fc8a","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki, Wody opadowe i roztopowe","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,00 – 1000) mg/dm3"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,00 – 1000) mg/dm3\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki, Wody opadowe i roztopowe Zawiesiny ogólne\nZakres (2,00 – 1000) mg/dm3\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, Woda do spozycia przez ludzi, Scieki, Wody opadowe i roztopowe Zawiesiny ogolne\nZakres (2,00 – 1000) mg/dm3\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":84,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2,00 – 1000) mg/dm3"}],"search_en":"Water, Water intended for human consumption, Wastewater, Rainwater and snowmelt water Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Water, Water intended for human consumption, Wastewater, Rainwater and snowmelt water","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,00 – 1000) mg/dm3"}],"search_zh":"水、生活饮用水、废水、雨水与融雪水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"水、生活饮用水、废水、雨水与融雪水"},{"_id":"6a837952af14b9c0e7b1fc8b","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Wody opadowe i roztopowe, Ścieki","methodology":"Indeks nadmanganianowy","parameters":[{"name":"Zakres","range":"(5 – 100) mg/dm3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Indeks nadmanganianowy\nZakres (5 – 100) mg/dm3\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wody opadowe i roztopowe, Ścieki Indeks nadmanganianowy\nZakres (5 – 100) mg/dm3\nMetoda miareczkowa PN-EN ISO 8467:2001 Wody opadowe i roztopowe, Scieki Indeks nadmanganianowy\nZakres (5 – 100) mg/dm3\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":85,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Permanganate index","parameters_en":[{"name":"Range","range":"(5 – 100) mg/dm3"}],"search_en":"Rainwater and snowmelt water, Wastewater Permanganate index Titrimetric method Range PN-EN ISO 8467:2001","technique_en":"Titrimetric method","test_object_en":"Rainwater and snowmelt water, Wastewater","methodology_zh":"高锰酸盐指数","parameters_zh":[{"name":"范围","range":"(5 – 100) mg/dm3"}],"search_zh":"高锰酸盐指数 滴定法 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法"},{"_id":"6a837952af14b9c0e7b1fc8c","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie rtęci","parameters":[{"name":"Zakres","range":"0,05 μg/dm3 – 30 mg/dm3"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","techniques":["Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji"],"computed":[],"activity":"Stężenie rtęci\nZakres 0,05 μg/dm3 – 30 mg/dm3\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","reference":"PB-21 wydanie 8 z dnia 30.03.2026 r.","norm_bases":["PB-21 wydanie 8 z dnia 30.03.2026 r."],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie rtęci\nZakres 0,05 μg/dm3 – 30 mg/dm3\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji PB-21 wydanie 8 z dnia 30.03.2026 r. Scieki Stezenie rteci\nZakres 0,05 μg/dm3 – 30 mg/dm3\nMetoda absorpcyjnej spektrometrii atomowej z technika amalgamacji PB-21 wydanie 8 z dnia 30.03.2026 r.","categories":["water"],"row_index":86,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury concentration","parameters_en":[{"name":"Range","range":"0,05 μg/dm3 – 30 mg/dm3"}],"search_en":"Wastewater Mercury concentration Atomic absorption spectrometry with amalgamation technique Range PB-21 wydanie 8 z dnia 30.03.2026 r.","technique_en":"Atomic absorption spectrometry with amalgamation technique","test_object_en":"Wastewater","methodology_zh":"汞浓度","parameters_zh":[{"name":"范围","range":"0,05 μg/dm3 – 30 mg/dm3"}],"search_zh":"污水 汞浓度 原子吸收光谱法（汞齐化技术） 范围 PB-21 wydanie 8 z dnia 30.03.2026 r.","technique_zh":"原子吸收光谱法（汞齐化技术）","test_object_zh":"污水"},{"_id":"6a837952af14b9c0e7b1fc8d","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)","parameters":[{"name":"naftalen","range":"(1 – 1000) ng/dm3"},{"name":"acenaftylen","range":"(1 – 1000) ng/dm3"},{"name":"acenaften","range":"(1 – 1000) ng/dm3"},{"name":"fluoren","range":"(1 – 1000) ng/dm3"},{"name":"fenantren","range":"(1 – 1000) ng/dm3"},{"name":"antracen","range":"(1 – 1000) ng/dm3"},{"name":"fluoranten","range":"(1 – 1000) ng/dm3"},{"name":"piren","range":"(1 – 1000) ng/dm3"},{"name":"benzo(a)antracen","range":"(1 – 1000) ng/dm3"},{"name":"chryzen","range":"(1 – 1000) ng/dm3"},{"name":"benzo(b)fluoranten","range":"(1 – 1000) ng/dm3"},{"name":"benzo(k)fluoranten","range":"(1 – 1000) ng/dm3"},{"name":"benzo(a)piren","range":"(1 – 1000) ng/dm3"},{"name":"indeno(1,2,3,-cd)piren","range":"(1 – 1000) ng/dm3"},{"name":"dibenzo(a,h)antracen","range":"(1 – 1000) ng/dm3"},{"name":"benzo(g,h,i)perylen","range":"(1 – 1000) ng/dm3"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)\nZakres:\nnaftalen (1 – 1000) ng/dm3\nacenaftylen (1 – 1000) ng/dm3\nacenaften (1 – 1000) ng/dm3\nfluoren (1 – 1000) ng/dm3\nfenantren (1 – 1000) ng/dm3\nantracen (1 – 1000) ng/dm3\nfluoranten (1 – 1000) ng/dm3\npiren (1 – 1000) ng/dm3\nbenzo(a)antracen (1 – 1000) ng/dm3\nchryzen (1 – 1000) ng/dm3\nbenzo(b)fluoranten (1 – 1000) ng/dm3\nbenzo(k)fluoranten (1 – 1000) ng/dm3\nbenzo(a)piren (1 – 1000) ng/dm3\nindeno(1,2,3,-cd)piren (1 – 1000) ng/dm3\ndibenzo(a,h)antracen (1 – 1000) ng/dm3\nbenzo(g,h,i)perylen (1 – 1000) ng/dm3\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"PB-02 wydanie 6 z dnia 22.02.2024 r.","norm_bases":["PB-02 wydanie 6 z dnia 22.02.2024 r."],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)\nZakres:\nnaftalen (1 – 1000) ng/dm3\nacenaftylen (1 – 1000) ng/dm3\nacenaften (1 – 1000) ng/dm3\nfluoren (1 – 1000) ng/dm3\nfenantren (1 – 1000) ng/dm3\nantracen (1 – 1000) ng/dm3\nfluoranten (1 – 1000) ng/dm3\npiren (1 – 1000) ng/dm3\nbenzo(a)antracen (1 – 1000) ng/dm3\nchryzen (1 – 1000) ng/dm3\nbenzo(b)fluoranten (1 – 1000) ng/dm3\nbenzo(k)fluoranten (1 – 1000) ng/dm3\nbenzo(a)piren (1 – 1000) ng/dm3\nindeno(1,2,3,-cd)piren (1 – 1000) ng/dm3\ndibenzo(a,h)antracen (1 – 1000) ng/dm3\nbenzo(g,h,i)perylen (1 – 1000) ng/dm3\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) PB-02 wydanie 6 z dnia 22.02.2024 r. Scieki Stezenie wielopierscieniowych weglowodorow aromatycznych (WWA)\nZakres:\nnaftalen (1 – 1000) ng/dm3\nacenaftylen (1 – 1000) ng/dm3\nacenaften (1 – 1000) ng/dm3\nfluoren (1 – 1000) ng/dm3\nfenantren (1 – 1000) ng/dm3\nantracen (1 – 1000) ng/dm3\nfluoranten (1 – 1000) ng/dm3\npiren (1 – 1000) ng/dm3\nbenzo(a)antracen (1 – 1000) ng/dm3\nchryzen (1 – 1000) ng/dm3\nbenzo(b)fluoranten (1 – 1000) ng/dm3\nbenzo(k)fluoranten (1 – 1000) ng/dm3\nbenzo(a)piren (1 – 1000) ng/dm3\nindeno(1,2,3,-cd)piren (1 – 1000) ng/dm3\ndibenzo(a,h)antracen (1 – 1000) ng/dm3\nbenzo(g,h,i)perylen (1 – 1000) ng/dm3\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) PB-02 wydanie 6 z dnia 22.02.2024 r.","categories":["water"],"row_index":87,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of polycyclic aromatic hydrocarbons (PAH)","parameters_en":[{"name":"naphthalene","range":"(1 – 1000) ng/dm3"},{"name":"acenaphthylene","range":"(1 – 1000) ng/dm3"},{"name":"acenaphthene","range":"(1 – 1000) ng/dm3"},{"name":"fluorene","range":"(1 – 1000) ng/dm3"},{"name":"phenanthrene","range":"(1 – 1000) ng/dm3"},{"name":"anthracene","range":"(1 – 1000) ng/dm3"},{"name":"fluoranthene","range":"(1 – 1000) ng/dm3"},{"name":"pyrene","range":"(1 – 1000) ng/dm3"},{"name":"benzo(a)anthracene","range":"(1 – 1000) ng/dm3"},{"name":"chrysene","range":"(1 – 1000) ng/dm3"},{"name":"benzo(b)fluoranthene","range":"(1 – 1000) ng/dm3"},{"name":"benzo(k)fluoranthene","range":"(1 – 1000) ng/dm3"},{"name":"benzo(a)pyrene","range":"(1 – 1000) ng/dm3"},{"name":"indeno(1,2,3,-cd)pyrene","range":"(1 – 1000) ng/dm3"},{"name":"dibenzo(a,h)anthracene","range":"(1 – 1000) ng/dm3"},{"name":"benzo(g,h,i)perylene","range":"(1 – 1000) ng/dm3"}],"search_en":"Wastewater Concentration of polycyclic aromatic hydrocarbons (PAH) Gas chromatography with mass spectrometry detection (GC-MS) naphthalene acenaphthylene acenaphthene fluorene phenanthrene anthracene fluoranthene pyrene benzo(a)anthracene chrysene benzo(b)fluoranthene benzo(k)fluoranthene benzo(a)pyrene indeno(1,2,3,-cd)pyrene dibenzo(a,h)anthracene benzo(g,h,i)perylene PB-02 wydanie 6 z dnia 22.02.2024 r.","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","test_object_en":"Wastewater","search_zh":"污水 多环芳烃（PAHs）浓度 气相色谱-质谱法（GC-MS） 萘 苊烯 苊 芴 菲 蒽 荧蒽 芘 苯并（a）蒽 䓛 苯并（b）荧蒽 苯并（k）荧蒽 苯并（a）芘 二苯并（a,h）蒽 苯并(g,h,i)苝 PB-02 wydanie 6 z dnia 22.02.2024 r.","technique_zh":"气相色谱-质谱法（GC-MS）","test_object_zh":"污水","parameters_zh":[{"name":"萘","range":"(1 – 1000) ng/dm3"},{"name":"苊烯","range":"(1 – 1000) ng/dm3"},{"name":"苊","range":"(1 – 1000) ng/dm3"},{"name":"芴","range":"(1 – 1000) ng/dm3"},{"name":"菲","range":"(1 – 1000) ng/dm3"},{"name":"蒽","range":"(1 – 1000) ng/dm3"},{"name":"荧蒽","range":"(1 – 1000) ng/dm3"},{"name":"芘","range":"(1 – 1000) ng/dm3"},{"name":"苯并（a）蒽","range":"(1 – 1000) ng/dm3"},{"name":"䓛","range":"(1 – 1000) ng/dm3"},{"name":"苯并（b）荧蒽","range":"(1 – 1000) ng/dm3"},{"name":"苯并（k）荧蒽","range":"(1 – 1000) ng/dm3"},{"name":"苯并（a）芘","range":"(1 – 1000) ng/dm3"},{"name":"indeno(1,2,3,-cd)piren","range":"(1 – 1000) ng/dm3"},{"name":"二苯并（a,h）蒽","range":"(1 – 1000) ng/dm3"},{"name":"苯并(g,h,i)苝","range":"(1 – 1000) ng/dm3"}],"methodology_zh":"多环芳烃（PAHs）浓度"},{"_id":"6a837952af14b9c0e7b1fc8e","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Ścieki","methodology":"Suma wielopierścieniowych węglowodorów aromatycznych (WWA) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma wielopierścieniowych węglowodorów aromatycznych (WWA) (z obliczeń)","reference":"I-24 wydanie 3 z dnia 26.02.2024 r.","norm_bases":["I-24 wydanie 3 z dnia 26.02.2024 r."],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Suma wielopierścieniowych węglowodorów aromatycznych (WWA) (z obliczeń) I-24 wydanie 3 z dnia 26.02.2024 r. Scieki Suma wielopierscieniowych weglowodorow aromatycznych (WWA) (z obliczen) I-24 wydanie 3 z dnia 26.02.2024 r.","categories":["water"],"row_index":88,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of polycyclic aromatic hydrocarbons (PAH) (calculated)","search_en":"Wastewater Sum of polycyclic aromatic hydrocarbons (PAH) (calculated) I-24 wydanie 3 z dnia 26.02.2024 r.","test_object_en":"Wastewater","search_zh":"污水 多环芳烃（PAH）总量（由计算得出） I-24 wydanie 3 z dnia 26.02.2024 r.","test_object_zh":"污水","methodology_zh":"多环芳烃（PAH）总量（由计算得出）"},{"_id":"6a837952af14b9c0e7b1fc8f","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie 17β-estradiolu (E2)","parameters":[{"name":"Zakres","range":"(0,10 –5,0) μg/dm3"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Stężenie 17β-estradiolu (E2)\nZakres (0,10 –5,0) μg/dm3\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"PB-46 wydanie 3 z dnia 22.02.2024 r.","norm_bases":["PB-46 wydanie 3 z dnia 22.02.2024 r."],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie 17β-estradiolu (E2)\nZakres (0,10 –5,0) μg/dm3\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) PB-46 wydanie 3 z dnia 22.02.2024 r. Scieki Stezenie 17β-estradiolu (E2)\nZakres (0,10 –5,0) μg/dm3\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) PB-46 wydanie 3 z dnia 22.02.2024 r.","categories":["water"],"row_index":89,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"17β-estradiol (E2) concentration","parameters_en":[{"name":"Range","range":"(0,10 –5,0) μg/dm3"}],"search_en":"Wastewater 17β-estradiol (E2) concentration Gas chromatography with mass spectrometry detection (GC-MS) Range PB-46 wydanie 3 z dnia 22.02.2024 r.","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(0,10 –5,0) μg/dm3"}],"search_zh":"污水 气相色谱-质谱法（GC-MS） 范围 PB-46 wydanie 3 z dnia 22.02.2024 r.","technique_zh":"气相色谱-质谱法（GC-MS）","test_object_zh":"污水"},{"_id":"6a837952af14b9c0e7b1fc90","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie 17α-etynyloestradiolu (EE2)","parameters":[{"name":"Zakres","range":"(0,10 – 5,0) μg/dm3"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Stężenie 17α-etynyloestradiolu (EE2)\nZakres (0,10 – 5,0) μg/dm3\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"PB-46 wydanie 3 z dnia 22.02.2024 r.","norm_bases":["PB-46 wydanie 3 z dnia 22.02.2024 r."],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie 17α-etynyloestradiolu (EE2)\nZakres (0,10 – 5,0) μg/dm3\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) PB-46 wydanie 3 z dnia 22.02.2024 r. Scieki Stezenie 17α-etynyloestradiolu (EE2)\nZakres (0,10 – 5,0) μg/dm3\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) PB-46 wydanie 3 z dnia 22.02.2024 r.","categories":["water"],"row_index":90,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"17α-ethinylestradiol (EE2) concentration","parameters_en":[{"name":"Range","range":"(0,10 – 5,0) μg/dm3"}],"search_en":"Wastewater 17α-ethinylestradiol (EE2) concentration Gas chromatography with mass spectrometry detection (GC-MS) Range PB-46 wydanie 3 z dnia 22.02.2024 r.","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(0,10 – 5,0) μg/dm3"}],"search_zh":"污水 气相色谱-质谱法（GC-MS） 范围 PB-46 wydanie 3 z dnia 22.02.2024 r.","technique_zh":"气相色谱-质谱法（GC-MS）","test_object_zh":"污水"},{"_id":"6a837952af14b9c0e7b1fc91","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie bisfenolu A","parameters":[{"name":"Zakres","range":"(0,10 – 5,0) μg/dm3"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Stężenie bisfenolu A\nZakres (0,10 – 5,0) μg/dm3\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"PB-46 wydanie 3 z dnia 22.02.2024 r.","norm_bases":["PB-46 wydanie 3 z dnia 22.02.2024 r."],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie bisfenolu A\nZakres (0,10 – 5,0) μg/dm3\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) PB-46 wydanie 3 z dnia 22.02.2024 r. Scieki Stezenie bisfenolu A\nZakres (0,10 – 5,0) μg/dm3\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) PB-46 wydanie 3 z dnia 22.02.2024 r.","categories":["water"],"row_index":91,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Bisphenol A concentration","parameters_en":[{"name":"Range","range":"(0,10 – 5,0) μg/dm3"}],"search_en":"Wastewater Bisphenol A concentration Gas chromatography with mass spectrometry detection (GC-MS) Range PB-46 wydanie 3 z dnia 22.02.2024 r.","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(0,10 – 5,0) μg/dm3"}],"search_zh":"污水 双酚 A 浓度 气相色谱-质谱法（GC-MS） 范围 PB-46 wydanie 3 z dnia 22.02.2024 r.","technique_zh":"气相色谱-质谱法（GC-MS）","test_object_zh":"污水","methodology_zh":"双酚 A 浓度"},{"_id":"6a837952af14b9c0e7b1fc92","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Grunty, Osady denne","methodology":"Zawartość rtęci","parameters":[{"name":"Zakres","range":"(0,010 – 6,0) mg/kg"}],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"computed":[],"activity":"Zawartość rtęci\nZakres (0,010 – 6,0) mg/kg\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"PB–42 wydanie 7 z dnia 05.06.2025 r.","norm_bases":["PB–42 wydanie 7 z dnia 05.06.2025 r."],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty, Osady denne Zawartość rtęci\nZakres (0,010 – 6,0) mg/kg\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) PB–42 wydanie 7 z dnia 05.06.2025 r. Grunty, Osady denne Zawartosc rteci\nZakres (0,010 – 6,0) mg/kg\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) PB–42 wydanie 7 z dnia 05.06.2025 r.","categories":["water"],"row_index":92,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury content","parameters_en":[{"name":"Range","range":"(0,010 – 6,0) mg/kg"}],"search_en":"Ground, Bottom sediments Mercury content Inductively coupled plasma mass spectrometry (ICP-MS) Range PB–42 wydanie 7 z dnia 05.06.2025 r.","technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","test_object_en":"Ground, Bottom sediments","methodology_zh":"汞含量","parameters_zh":[{"name":"范围","range":"(0,010 – 6,0) mg/kg"}],"search_zh":"汞含量 电感耦合等离子体质谱法（ICP-MS） 范围 PB–42 wydanie 7 z dnia 05.06.2025 r.","technique_zh":"电感耦合等离子体质谱法（ICP-MS）"},{"_id":"6a837952af14b9c0e7b1fc93","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Grunty, Osady denne","methodology":"Skład granulometryczny w zakresie wielkości cząstek (< 0,063 – 2,00) mm z podziałem na frakcje","parameters":[{"name":"Zakres","range":"(0,5 – 99,5) %"}],"technique":"Metoda sitowa","techniques":["Metoda sitowa"],"computed":[],"activity":"Skład granulometryczny w zakresie wielkości cząstek (< 0,063 – 2,00) mm z podziałem na frakcje\nZakres (0,5 – 99,5) %\nMetoda sitowa","reference":"PN-EN ISO 17892-4:2017-01","norm_bases":["PN-EN ISO 17892-4:2017-01"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty, Osady denne Skład granulometryczny w zakresie wielkości cząstek (< 0,063 – 2,00) mm z podziałem na frakcje\nZakres (0,5 – 99,5) %\nMetoda sitowa PN-EN ISO 17892-4:2017-01 Grunty, Osady denne Sklad granulometryczny w zakresie wielkosci czastek (< 0,063 – 2,00) mm z podzialem na frakcje\nZakres (0,5 – 99,5) %\nMetoda sitowa PN-EN ISO 17892-4:2017-01","categories":["water"],"row_index":93,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Particle size distribution in the particle size range (< 0,063 – 2,00) mm divided into fractions","parameters_en":[{"name":"Range","range":"(0,5 – 99,5) %"}],"search_en":"Ground, Bottom sediments Particle size distribution in the particle size range (< 0,063 – 2,00) mm divided into fractions Sieve method Range PN-EN ISO 17892-4:2017-01","technique_en":"Sieve method","test_object_en":"Ground, Bottom sediments","parameters_zh":[{"name":"范围","range":"(0,5 – 99,5) %"}],"search_zh":"筛析法 范围 PN-EN ISO 17892-4:2017-01","technique_zh":"筛析法"},{"_id":"6a837952af14b9c0e7b1fc94","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Grunty, Osady denne","methodology":"Wodoprzepuszczalność - współczynnik filtracji","parameters":[{"name":"Zakres","range":"(10-7 – 10-1) m/s"},{"name":"(z obliczeń na podstawie krzywej uziarnienia)"}],"technique":null,"techniques":[],"computed":[],"activity":"Wodoprzepuszczalność - współczynnik filtracji\nZakres:\nZakres (10-7 – 10-1) m/s\n(z obliczeń na podstawie krzywej uziarnienia)","reference":"PB-44 wydanie 3 z dnia 22.02.2024 r.","norm_bases":["PB-44 wydanie 3 z dnia 22.02.2024 r."],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty, Osady denne Wodoprzepuszczalność - współczynnik filtracji\nZakres:\nZakres (10-7 – 10-1) m/s\n(z obliczeń na podstawie krzywej uziarnienia) PB-44 wydanie 3 z dnia 22.02.2024 r. Grunty, Osady denne Wodoprzepuszczalnosc - wspolczynnik filtracji\nZakres:\nZakres (10-7 – 10-1) m/s\n(z obliczen na podstawie krzywej uziarnienia) PB-44 wydanie 3 z dnia 22.02.2024 r.","categories":["water"],"row_index":94,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water permeability - coefficient of permeability","parameters_en":[{"name":"Range","range":"(10-7 – 10-1) m/s"},{"name":"(z obliczeń na podstawie krzywej uziarnienia)"}],"search_en":"Ground, Bottom sediments Water permeability - coefficient of permeability Range PB-44 wydanie 3 z dnia 22.02.2024 r.","test_object_en":"Ground, Bottom sediments","parameters_zh":[{"name":"范围","range":"(10-7 – 10-1) m/s"},{"name":"(z obliczeń na podstawie krzywej uziarnienia)"}],"search_zh":"透水性 － 渗透系数 范围 PB-44 wydanie 3 z dnia 22.02.2024 r.","methodology_zh":"透水性 － 渗透系数"},{"_id":"6a837952af14b9c0e7b1fc95","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Grunty, Osady denne, Osady ściekowe","methodology":"Sucha masa / zawartość wody","parameters":[{"name":"Zakres","range":"(0,5 – 99,9) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha masa / zawartość wody\nZakres (0,5 – 99,9) %\nMetoda wagowa","reference":"PN-EN ISO 11465:2026-03","norm_bases":["PN-EN ISO 11465:2026-03"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty, Osady denne, Osady ściekowe Sucha masa / zawartość wody\nZakres (0,5 – 99,9) %\nMetoda wagowa PN-EN ISO 11465:2026-03 Grunty, Osady denne, Osady sciekowe Sucha masa / zawartosc wody\nZakres (0,5 – 99,9) %\nMetoda wagowa PN-EN ISO 11465:2026-03","categories":["water"],"row_index":95,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry matter / water content","parameters_en":[{"name":"Range","range":"(0,5 – 99,9) %"}],"search_en":"Ground, Bottom sediments, Sewage sludge Dry matter / water content Gravimetric method Range PN-EN ISO 11465:2026-03","technique_en":"Gravimetric method","test_object_en":"Ground, Bottom sediments, Sewage sludge","parameters_zh":[{"name":"范围","range":"(0,5 – 99,9) %"}],"search_zh":"土体、底泥、污水污泥 干物质 / 水分含量 重量法 范围 PN-EN ISO 11465:2026-03","technique_zh":"重量法","methodology_zh":"干物质 / 水分含量","test_object_zh":"土体、底泥、污水污泥"},{"_id":"6a837952af14b9c0e7b1fc96","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Grunty, Osady denne, Osady ściekowe","methodology":"pH - w H2O, pH - w KCl","parameters":[{"name":"Zakres","range":"2,0 – 13,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH - w H2O, pH - w KCl\nZakres 2,0 – 13,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty, Osady denne, Osady ściekowe pH - w H2O, pH - w KCl\nZakres 2,0 – 13,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 Grunty, Osady denne, Osady sciekowe pH - w H2O, pH - w KCl\nZakres 2,0 – 13,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["water"],"row_index":96,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH - in H2O, pH - in KCl","parameters_en":[{"name":"Range","range":"2,0 – 13,0"}],"search_en":"Ground, Bottom sediments, Sewage sludge pH - in H2O, pH - in KCl Potentiometric method Range PN-EN ISO 10390:2022-09","technique_en":"Potentiometric method","test_object_en":"Ground, Bottom sediments, Sewage sludge","parameters_zh":[{"name":"范围","range":"2,0 – 13,0"}],"search_zh":"土体、底泥、污水污泥 pH － 于 H2O 中，pH － 于 KCl 中 电位法 范围 PN-EN ISO 10390:2022-09","technique_zh":"电位法","test_object_zh":"土体、底泥、污水污泥","methodology_zh":"pH － 于 H2O 中，pH － 于 KCl 中"},{"_id":"6a837952af14b9c0e7b1fc97","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Grunty, Osady denne, Osady ściekowe","methodology":"Straty przy prażeniu suchej masy (LOI)","parameters":[{"name":"Zakres","range":"(0,1 – 99,9) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Straty przy prażeniu suchej masy (LOI)\nZakres (0,1 – 99,9) %\nMetoda wagowa","reference":"PN-EN 15935:2022-01","norm_bases":["PN-EN 15935:2022-01"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty, Osady denne, Osady ściekowe Straty przy prażeniu suchej masy (LOI)\nZakres (0,1 – 99,9) %\nMetoda wagowa PN-EN 15935:2022-01 Grunty, Osady denne, Osady sciekowe Straty przy prazeniu suchej masy (LOI)\nZakres (0,1 – 99,9) %\nMetoda wagowa PN-EN 15935:2022-01","categories":["water"],"row_index":97,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Loss on ignition of dry matter (LOI)","parameters_en":[{"name":"Range","range":"(0,1 – 99,9) %"}],"search_en":"Ground, Bottom sediments, Sewage sludge Loss on ignition of dry matter (LOI) Gravimetric method Range PN-EN 15935:2022-01","technique_en":"Gravimetric method","test_object_en":"Ground, Bottom sediments, Sewage sludge","parameters_zh":[{"name":"范围","range":"(0,1 – 99,9) %"}],"search_zh":"土体、底泥、污水污泥 干物质烧失量（LOI） 重量法 范围 PN-EN 15935:2022-01","technique_zh":"重量法","methodology_zh":"干物质烧失量（LOI）","test_object_zh":"土体、底泥、污水污泥"},{"_id":"6a837952af14b9c0e7b1fc98","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Grunty, Osady denne, Osady ściekowe","methodology":"Zawartość węglowodorów w zakresie C10 do C40 (oleje mineralne)","parameters":[{"name":"Zakres","range":"(5,0 – 10 000) mg/ kg"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość węglowodorów w zakresie C10 do C40 (oleje mineralne)\nZakres (5,0 – 10 000) mg/ kg\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN ISO 16703:2011","norm_bases":["PN-EN ISO 16703:2011"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty, Osady denne, Osady ściekowe Zawartość węglowodorów w zakresie C10 do C40 (oleje mineralne)\nZakres (5,0 – 10 000) mg/ kg\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN ISO 16703:2011 Grunty, Osady denne, Osady sciekowe Zawartosc weglowodorow w zakresie C10 do C40 (oleje mineralne)\nZakres (5,0 – 10 000) mg/ kg\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN ISO 16703:2011","categories":["water","petro"],"row_index":98,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of hydrocarbons in the range C10 to C40 (mineral oils)","parameters_en":[{"name":"Range","range":"(5,0 – 10 000) mg/ kg"}],"search_en":"Ground, Bottom sediments, Sewage sludge Content of hydrocarbons in the range C10 to C40 (mineral oils) Gas chromatography with flame ionization detection (GC-FID) Range PN-EN ISO 16703:2011","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Ground, Bottom sediments, Sewage sludge","parameters_zh":[{"name":"范围","range":"(5,0 – 10 000) mg/ kg"}],"search_zh":"土体、底泥、污水污泥 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-EN ISO 16703:2011","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"土体、底泥、污水污泥"},{"_id":"6a837952af14b9c0e7b1fc99","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Grunty, Osady denne, Osady ściekowe","methodology":"Suma wielopierścieniowych węglowodorów aromatycznych (WWA) i węglowodorów w zakresie C10 do C40 (oleje mineralne) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma wielopierścieniowych węglowodorów aromatycznych (WWA) i węglowodorów w zakresie C10 do C40 (oleje mineralne) (z obliczeń)","reference":"I-24 wydanie 3 z dnia 26.02.2024 r.","norm_bases":["I-24 wydanie 3 z dnia 26.02.2024 r."],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty, Osady denne, Osady ściekowe Suma wielopierścieniowych węglowodorów aromatycznych (WWA) i węglowodorów w zakresie C10 do C40 (oleje mineralne) (z obliczeń) I-24 wydanie 3 z dnia 26.02.2024 r. Grunty, Osady denne, Osady sciekowe Suma wielopierscieniowych weglowodorow aromatycznych (WWA) i weglowodorow w zakresie C10 do C40 (oleje mineralne) (z obliczen) I-24 wydanie 3 z dnia 26.02.2024 r.","categories":["water","petro"],"row_index":99,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of polycyclic aromatic hydrocarbons (PAH) and hydrocarbons in the range C10 to C40 (mineral oils) (calculated)","search_en":"Ground, Bottom sediments, Sewage sludge Sum of polycyclic aromatic hydrocarbons (PAH) and hydrocarbons in the range C10 to C40 (mineral oils) (calculated) I-24 wydanie 3 z dnia 26.02.2024 r.","test_object_en":"Ground, Bottom sediments, Sewage sludge","search_zh":"土体、底泥、污水污泥 I-24 wydanie 3 z dnia 26.02.2024 r.","test_object_zh":"土体、底泥、污水污泥"},{"_id":"6a837952af14b9c0e7b1fc9a","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Grunty, Osady denne, Osady ściekowe","methodology":"Zawartość węglowodorów C6-C12 (frakcji benzyn)","parameters":[{"name":"Zakres","range":"(1,0 – 1000) mg/kg"}],"technique":"Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)","techniques":["Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)"],"computed":[],"activity":"Zawartość węglowodorów C6-C12 (frakcji benzyn)\nZakres (1,0 – 1000) mg/kg\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)","reference":"PB-43 wydanie 3 z dnia 22.02.2024 r.","norm_bases":["PB-43 wydanie 3 z dnia 22.02.2024 r."],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty, Osady denne, Osady ściekowe Zawartość węglowodorów C6-C12 (frakcji benzyn)\nZakres (1,0 – 1000) mg/kg\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS) PB-43 wydanie 3 z dnia 22.02.2024 r. Grunty, Osady denne, Osady sciekowe Zawartosc weglowodorow C6-C12 (frakcji benzyn)\nZakres (1,0 – 1000) mg/kg\nMetoda chromatografii gazowej z analiza fazy nadpowierzchniowej i detekcja spektrometria mas (HS-GC-MS) PB-43 wydanie 3 z dnia 22.02.2024 r.","categories":["water"],"row_index":100,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of hydrocarbons C6-C12 (petrol fraction)","parameters_en":[{"name":"Range","range":"(1,0 – 1000) mg/kg"}],"search_en":"Ground, Bottom sediments, Sewage sludge Content of hydrocarbons C6-C12 (petrol fraction) Headspace gas chromatography with mass spectrometry detection (HS-GC-MS) Range PB-43 wydanie 3 z dnia 22.02.2024 r.","technique_en":"Headspace gas chromatography with mass spectrometry detection (HS-GC-MS)","test_object_en":"Ground, Bottom sediments, Sewage sludge","parameters_zh":[{"name":"范围","range":"(1,0 – 1000) mg/kg"}],"search_zh":"土体、底泥、污水污泥 顶空气相色谱-质谱法（HS-GC-MS） 范围 PB-43 wydanie 3 z dnia 22.02.2024 r.","technique_zh":"顶空气相色谱-质谱法（HS-GC-MS）","test_object_zh":"土体、底泥、污水污泥"},{"_id":"6a837952af14b9c0e7b1fc9b","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"OdpadyDAB-11: Osady i odpady mineralne (I), Odpady budowlane (III), Osady z procesów przemysłowych (VII), Odpady z oczyszczania gazów odlotowych (X), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV), OdpadO) kod: 19 09 99","methodology":"Pobieranie próbek do badań fizycznych i chemicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań fizycznych i chemicznych","reference":"I-28 wydanie 2 z dnia 26.02.2024 r.","norm_bases":["I-28 wydanie 2 z dnia 26.02.2024 r."],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":"Pobieranie wykonywane dla celów obszaru regulowanego objętego:\n- Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz.U. 2015 poz. 1277)\n- Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (Dz.U. 2015 poz. 257 z późn. zm.)\n- Rozporządzeniem Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz.U. 2015 poz. 132)\n- Rozporządzeniem Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz.U. 2015 poz. 796)\nDAB-11) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grup walidacyjnych podano w Załączniku nr 1 do DAB-11\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"OdpadyDAB-11: Osady i odpady mineralne (I), Odpady budowlane (III), Osady z procesów przemysłowych (VII), Odpady z oczyszczania gazów odlotowych (X), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV), OdpadO) kod: 19 09 99 Pobieranie próbek do badań fizycznych i chemicznych I-28 wydanie 2 z dnia 26.02.2024 r. OdpadyDAB-11: Osady i odpady mineralne (I), Odpady budowlane (III), Osady z procesow przemyslowych (VII), Odpady z oczyszczania gazow odlotowych (X), Zuzle, popioly i pyly paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV), OdpadO) kod: 19 09 99 Pobieranie probek do badan fizycznych i chemicznych I-28 wydanie 2 z dnia 26.02.2024 r.","categories":["water","environment","construction"],"row_index":101,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for physical and chemical testing","search_en":"Sampling for physical and chemical testing I-28 wydanie 2 z dnia 26.02.2024 r.","methodology_zh":"物理与化学检测用样品采集","search_zh":"物理与化学检测用样品采集 I-28 wydanie 2 z dnia 26.02.2024 r."},{"_id":"6a837952af14b9c0e7b1fc9c","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"OdpadO) kod: 19 08 05","methodology":"Pobieranie próbek do badań fizycznych i chemicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań fizycznych i chemicznych","reference":"PN-EN ISO 5667-13:2011 z wyłączeniem punktów 6.3.3; 6.3.4; 6.3.5; 6.3.7; 6.3.8.5","norm_bases":["PN-EN ISO 5667-13:2011 z wyłączeniem punktów 6.3.3; 6.3.4; 6.3.5; 6.3.7; 6.3.8.5"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":"Pobieranie wykonywane dla celów obszaru regulowanego objętego:\n- Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz.U. 2015 poz. 1277)\n- Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (Dz.U. 2015 poz. 257 z późn. zm.)\n- Rozporządzeniem Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz.U. 2015 poz. 132)\n- Rozporządzeniem Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz.U. 2015 poz. 796)\nDAB-11) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grup walidacyjnych podano w Załączniku nr 1 do DAB-11\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"OdpadO) kod: 19 08 05 Pobieranie próbek do badań fizycznych i chemicznych PN-EN ISO 5667-13:2011 z wyłączeniem punktów 6.3.3; 6.3.4; 6.3.5; 6.3.7; 6.3.8.5 OdpadO) kod: 19 08 05 Pobieranie probek do badan fizycznych i chemicznych PN-EN ISO 5667-13:2011 z wylaczeniem punktow 6.3.3; 6.3.4; 6.3.5; 6.3.7; 6.3.8.5","categories":["environment"],"row_index":102,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for physical and chemical testing","search_en":"WasteO) code: 19 08 05 Sampling for physical and chemical testing PN-EN ISO 5667-13:2011 z wyłączeniem punktów 6.3.3; 6.3.4; 6.3.5; 6.3.7; 6.3.8.5","test_object_en":"WasteO) code: 19 08 05","methodology_zh":"物理与化学检测用样品采集","search_zh":"物理与化学检测用样品采集 PN-EN ISO 5667-13:2011 z wyłączeniem punktów 6.3.3; 6.3.4; 6.3.5; 6.3.7; 6.3.8.5"},{"_id":"6a837952af14b9c0e7b1fc9d","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"OdpadyDAB-11: Osady i odpady mineralne (I), Odpady budowlane (III), Osady z procesów przemysłowych (VII), Odpady z oczyszczania gazów odlotowych (X), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV);, OdpadyO) kod: 02 03 80, 04 02 21, 19 09 99","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,5"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 12,5\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012 | PN-EN 12457-2:2006","norm_bases":["PN-EN ISO 10523:2012","PN-EN 12457-2:2006"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz.U. 2015 poz. 1277)\nDAB-11) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grup walidacyjnych podano w Załączniku nr 1 do DAB-11\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"OdpadyDAB-11: Osady i odpady mineralne (I), Odpady budowlane (III), Osady z procesów przemysłowych (VII), Odpady z oczyszczania gazów odlotowych (X), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV);, OdpadyO) kod: 02 03 80, 04 02 21, 19 09 99 pH\nZakres 2,0 – 12,5\nMetoda potencjometryczna PN-EN ISO 10523:2012 | PN-EN 12457-2:2006 OdpadyDAB-11: Osady i odpady mineralne (I), Odpady budowlane (III), Osady z procesow przemyslowych (VII), Odpady z oczyszczania gazow odlotowych (X), Zuzle, popioly i pyly paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV);, OdpadyO) kod: 02 03 80, 04 02 21, 19 09 99 pH\nZakres 2,0 – 12,5\nMetoda potencjometryczna PN-EN ISO 10523:2012 | PN-EN 12457-2:2006","categories":["water","environment","construction"],"row_index":103,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 – 12,5"}],"search_en":"pH Potentiometric method Range PN-EN ISO 10523:2012 | PN-EN 12457-2:2006","technique_en":"Potentiometric method","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 12,5"}],"search_zh":"pH 值 电位法 范围 PN-EN ISO 10523:2012 | PN-EN 12457-2:2006","technique_zh":"电位法"},{"_id":"6a837952af14b9c0e7b1fc9e","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"OdpadyDAB-11: Osady i odpady mineralne (I), Odpady budowlane (III), Osady z procesów przemysłowych (VII), Odpady z oczyszczania gazów odlotowych (X), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV);, OdpadyO) kod: 02 03 80, 04 02 21, 19 09 99","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(50 – 50 000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (50 – 50 000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999 | PN-EN 12457-2:2006","norm_bases":["PN-EN 27888:1999","PN-EN 12457-2:2006"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz.U. 2015 poz. 1277)\nDAB-11) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grup walidacyjnych podano w Załączniku nr 1 do DAB-11\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"OdpadyDAB-11: Osady i odpady mineralne (I), Odpady budowlane (III), Osady z procesów przemysłowych (VII), Odpady z oczyszczania gazów odlotowych (X), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV);, OdpadyO) kod: 02 03 80, 04 02 21, 19 09 99 Przewodność elektryczna właściwa\nZakres (50 – 50 000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 | PN-EN 12457-2:2006 OdpadyDAB-11: Osady i odpady mineralne (I), Odpady budowlane (III), Osady z procesow przemyslowych (VII), Odpady z oczyszczania gazow odlotowych (X), Zuzle, popioly i pyly paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV);, OdpadyO) kod: 02 03 80, 04 02 21, 19 09 99 Przewodnosc elektryczna wlasciwa\nZakres (50 – 50 000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 | PN-EN 12457-2:2006","categories":["water","environment","construction"],"row_index":104,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(50 – 50 000) μS/cm"}],"search_en":"Electrical conductivity Conductometric method Range PN-EN 27888:1999 | PN-EN 12457-2:2006","technique_en":"Conductometric method","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(50 – 50 000) μS/cm"}],"search_zh":"电导率 电导法 范围 PN-EN 27888:1999 | PN-EN 12457-2:2006","technique_zh":"电导法"},{"_id":"6a837952af14b9c0e7b1fc9f","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"OdpadyDAB-11: Osady i odpady mineralne (I), Odpady budowlane (III), Osady z procesów przemysłowych (VII), Odpady z oczyszczania gazów odlotowych (X), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV);, OdpadyO) kod: 02 03 80, 04 02 21, 19 09 99","methodology":"Zawartość arsenu","parameters":[{"name":"Zakres","range":"(0,01 – 0,50) mg/kg"}],"technique":"Metoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z techniką generacji wodorków (HG-ICP-OES)","techniques":["Metoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z techniką generacji wodorków (HG-ICP-OES)"],"computed":[],"activity":"Zawartość arsenu\nZakres (0,01 – 0,50) mg/kg\nMetoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z techniką generacji wodorków (HG-ICP-OES)","reference":"PB-25 wydanie 5 z dnia 22.02.2024 r. | PN-EN 12457-2:2006","norm_bases":["PB-25 wydanie 5 z dnia 22.02.2024 r.","PN-EN 12457-2:2006"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz.U. 2015 poz. 1277)\nDAB-11) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grup walidacyjnych podano w Załączniku nr 1 do DAB-11\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"OdpadyDAB-11: Osady i odpady mineralne (I), Odpady budowlane (III), Osady z procesów przemysłowych (VII), Odpady z oczyszczania gazów odlotowych (X), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV);, OdpadyO) kod: 02 03 80, 04 02 21, 19 09 99 Zawartość arsenu\nZakres (0,01 – 0,50) mg/kg\nMetoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z techniką generacji wodorków (HG-ICP-OES) PB-25 wydanie 5 z dnia 22.02.2024 r. | PN-EN 12457-2:2006 OdpadyDAB-11: Osady i odpady mineralne (I), Odpady budowlane (III), Osady z procesow przemyslowych (VII), Odpady z oczyszczania gazow odlotowych (X), Zuzle, popioly i pyly paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV);, OdpadyO) kod: 02 03 80, 04 02 21, 19 09 99 Zawartosc arsenu\nZakres (0,01 – 0,50) mg/kg\nMetoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzezonej z technika generacji wodorkow (HG-ICP-OES) PB-25 wydanie 5 z dnia 22.02.2024 r. | PN-EN 12457-2:2006","categories":["water","environment","construction"],"row_index":105,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Arsenic content","parameters_en":[{"name":"Range","range":"(0,01 – 0,50) mg/kg"}],"search_en":"Arsenic content Range PB-25 wydanie 5 z dnia 22.02.2024 r. | PN-EN 12457-2:2006","parameters_zh":[{"name":"范围","range":"(0,01 – 0,50) mg/kg"}],"search_zh":"砷含量 范围 PB-25 wydanie 5 z dnia 22.02.2024 r. | PN-EN 12457-2:2006","methodology_zh":"砷含量"},{"_id":"6a837952af14b9c0e7b1fca0","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"OdpadyDAB-11: Osady i odpady mineralne (I), Odpady budowlane (III), Osady z procesów przemysłowych (VII), Odpady z oczyszczania gazów odlotowych (X), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV);, OdpadyO) kod: 02 03 80, 04 02 21, 19 09 99","methodology":"Zawartość antymonu","parameters":[{"name":"Zakres","range":"(0,01 – 0,50) mg/kg"}],"technique":"Metoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z techniką generacji wodorków (HG-ICP-OES)","techniques":["Metoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z techniką generacji wodorków (HG-ICP-OES)"],"computed":[],"activity":"Zawartość antymonu\nZakres (0,01 – 0,50) mg/kg\nMetoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z techniką generacji wodorków (HG-ICP-OES)","reference":"PB-18 wydanie 6 z dnia 22.02.2024 r. | PN-EN 12457-2:2006","norm_bases":["PB-18 wydanie 6 z dnia 22.02.2024 r.","PN-EN 12457-2:2006"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz.U. 2015 poz. 1277)\nDAB-11) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grup walidacyjnych podano w Załączniku nr 1 do DAB-11\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"OdpadyDAB-11: Osady i odpady mineralne (I), Odpady budowlane (III), Osady z procesów przemysłowych (VII), Odpady z oczyszczania gazów odlotowych (X), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV);, OdpadyO) kod: 02 03 80, 04 02 21, 19 09 99 Zawartość antymonu\nZakres (0,01 – 0,50) mg/kg\nMetoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z techniką generacji wodorków (HG-ICP-OES) PB-18 wydanie 6 z dnia 22.02.2024 r. | PN-EN 12457-2:2006 OdpadyDAB-11: Osady i odpady mineralne (I), Odpady budowlane (III), Osady z procesow przemyslowych (VII), Odpady z oczyszczania gazow odlotowych (X), Zuzle, popioly i pyly paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV);, OdpadyO) kod: 02 03 80, 04 02 21, 19 09 99 Zawartosc antymonu\nZakres (0,01 – 0,50) mg/kg\nMetoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzezonej z technika generacji wodorkow (HG-ICP-OES) PB-18 wydanie 6 z dnia 22.02.2024 r. | PN-EN 12457-2:2006","categories":["water","environment","construction"],"row_index":106,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Antimony content","parameters_en":[{"name":"Range","range":"(0,01 – 0,50) mg/kg"}],"search_en":"Antimony content Range PB-18 wydanie 6 z dnia 22.02.2024 r. | PN-EN 12457-2:2006","parameters_zh":[{"name":"范围","range":"(0,01 – 0,50) mg/kg"}],"search_zh":"范围 PB-18 wydanie 6 z dnia 22.02.2024 r. | PN-EN 12457-2:2006"},{"_id":"6a837952af14b9c0e7b1fca1","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"OdpadyDAB-11: Osady i odpady mineralne (I), Odpady budowlane (III), Osady z procesów przemysłowych (VII), Odpady z oczyszczania gazów odlotowych (X), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV);, OdpadyO) kod: 02 03 80, 04 02 21, 19 09 99","methodology":"Zawartość selenu","parameters":[{"name":"Zakres","range":"(0,01 – 0,50) mg/kg"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES)"],"computed":[],"activity":"Zawartość selenu\nZakres (0,01 – 0,50) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES)","reference":"PB-26 wydanie 5 z dnia 22.02.2024 r. | PN-EN 12457-2:2006","norm_bases":["PB-26 wydanie 5 z dnia 22.02.2024 r.","PN-EN 12457-2:2006"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz.U. 2015 poz. 1277)\nDAB-11) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grup walidacyjnych podano w Załączniku nr 1 do DAB-11\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"OdpadyDAB-11: Osady i odpady mineralne (I), Odpady budowlane (III), Osady z procesów przemysłowych (VII), Odpady z oczyszczania gazów odlotowych (X), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV);, OdpadyO) kod: 02 03 80, 04 02 21, 19 09 99 Zawartość selenu\nZakres (0,01 – 0,50) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES) PB-26 wydanie 5 z dnia 22.02.2024 r. | PN-EN 12457-2:2006 OdpadyDAB-11: Osady i odpady mineralne (I), Odpady budowlane (III), Osady z procesow przemyslowych (VII), Odpady z oczyszczania gazow odlotowych (X), Zuzle, popioly i pyly paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV);, OdpadyO) kod: 02 03 80, 04 02 21, 19 09 99 Zawartosc selenu\nZakres (0,01 – 0,50) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej z generowaniem wodorkow (HG-ICP-OES) PB-26 wydanie 5 z dnia 22.02.2024 r. | PN-EN 12457-2:2006","categories":["water","environment","construction"],"row_index":107,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Selenium content","parameters_en":[{"name":"Range","range":"(0,01 – 0,50) mg/kg"}],"search_en":"Selenium content Hydride generation inductively coupled plasma optical emission spectrometry (HG-ICP-OES) Range PB-26 wydanie 5 z dnia 22.02.2024 r. | PN-EN 12457-2:2006","technique_en":"Hydride generation inductively coupled plasma optical emission spectrometry (HG-ICP-OES)","parameters_zh":[{"name":"范围","range":"(0,01 – 0,50) mg/kg"}],"search_zh":"硒含量 氢化物发生电感耦合等离子体发射光谱法（HG-ICP-OES） 范围 PB-26 wydanie 5 z dnia 22.02.2024 r. | PN-EN 12457-2:2006","technique_zh":"氢化物发生电感耦合等离子体发射光谱法（HG-ICP-OES）","methodology_zh":"硒含量"},{"_id":"6a837952af14b9c0e7b1fca2","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"OdpadyDAB-11: Osady i odpady mineralne (I), Odpady budowlane (III), Osady z procesów przemysłowych (VII), Odpady z oczyszczania gazów odlotowych (X), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV);, OdpadyO) kod: 02 03 80, 04 02 21, 19 09 99","methodology":"Zawartość selenu, arsenu, antymonu","parameters":[{"name":"Se","range":"(0,01 – 10) mg/kg"},{"name":"As","range":"(0,01 – 10) mg/kg"},{"name":"Sb","range":"(0,01 – 10) mg/kg"}],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"computed":[],"activity":"Zawartość selenu, arsenu, antymonu\nZakres:\nSe (0,01 – 10) mg/kg\nAs (0,01 – 10) mg/kg\nSb (0,01 – 10) mg/kg\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"PN-EN 12457-2:2006 | PN-EN ISO 17294-2:2024-04","norm_bases":["PN-EN 12457-2:2006","PN-EN ISO 17294-2:2024-04"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz.U. 2015 poz. 1277)\nDAB-11) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grup walidacyjnych podano w Załączniku nr 1 do DAB-11\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"OdpadyDAB-11: Osady i odpady mineralne (I), Odpady budowlane (III), Osady z procesów przemysłowych (VII), Odpady z oczyszczania gazów odlotowych (X), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV);, OdpadyO) kod: 02 03 80, 04 02 21, 19 09 99 Zawartość selenu, arsenu, antymonu\nZakres:\nSe (0,01 – 10) mg/kg\nAs (0,01 – 10) mg/kg\nSb (0,01 – 10) mg/kg\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) PN-EN 12457-2:2006 | PN-EN ISO 17294-2:2024-04 OdpadyDAB-11: Osady i odpady mineralne (I), Odpady budowlane (III), Osady z procesow przemyslowych (VII), Odpady z oczyszczania gazow odlotowych (X), Zuzle, popioly i pyly paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV);, OdpadyO) kod: 02 03 80, 04 02 21, 19 09 99 Zawartosc selenu, arsenu, antymonu\nZakres:\nSe (0,01 – 10) mg/kg\nAs (0,01 – 10) mg/kg\nSb (0,01 – 10) mg/kg\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) PN-EN 12457-2:2006 | PN-EN ISO 17294-2:2024-04","categories":["water","environment","construction"],"row_index":108,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Se","range":"(0,01 – 10) mg/kg"},{"name":"As","range":"(0,01 – 10) mg/kg"},{"name":"Sb","range":"(0,01 – 10) mg/kg"}],"search_en":"Inductively coupled plasma mass spectrometry (ICP-MS) Se As Sb PN-EN 12457-2:2006 | PN-EN ISO 17294-2:2024-04","technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","search_zh":"电感耦合等离子体质谱法（ICP-MS） Se As Sb PN-EN 12457-2:2006 | PN-EN ISO 17294-2:2024-04","technique_zh":"电感耦合等离子体质谱法（ICP-MS）","parameters_zh":[{"name":"Se","range":"(0,01 – 10) mg/kg"},{"name":"As","range":"(0,01 – 10) mg/kg"},{"name":"Sb","range":"(0,01 – 10) mg/kg"}]},{"_id":"6a837952af14b9c0e7b1fca3","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"OdpadyDAB-11: Osady i odpady mineralne (I), Odpady budowlane (III), Osady z procesów przemysłowych (VII), Odpady z oczyszczania gazów odlotowych (X), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV);, OdpadyO) kod: 02 03 80, 04 02 21, 19 09 99","methodology":"Zawartość substancji rozpuszczonych","parameters":[{"name":"Zakres","range":"(100 – 75 000) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość substancji rozpuszczonych\nZakres (100 – 75 000) mg/kg\nMetoda wagowa","reference":"PB-13 wydanie 5 z dnia 22.02.2024 r. | PN-EN 12457-2:2006","norm_bases":["PB-13 wydanie 5 z dnia 22.02.2024 r.","PN-EN 12457-2:2006"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz.U. 2015 poz. 1277)\nDAB-11) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grup walidacyjnych podano w Załączniku nr 1 do DAB-11\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"OdpadyDAB-11: Osady i odpady mineralne (I), Odpady budowlane (III), Osady z procesów przemysłowych (VII), Odpady z oczyszczania gazów odlotowych (X), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV);, OdpadyO) kod: 02 03 80, 04 02 21, 19 09 99 Zawartość substancji rozpuszczonych\nZakres (100 – 75 000) mg/kg\nMetoda wagowa PB-13 wydanie 5 z dnia 22.02.2024 r. | PN-EN 12457-2:2006 OdpadyDAB-11: Osady i odpady mineralne (I), Odpady budowlane (III), Osady z procesow przemyslowych (VII), Odpady z oczyszczania gazow odlotowych (X), Zuzle, popioly i pyly paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV);, OdpadyO) kod: 02 03 80, 04 02 21, 19 09 99 Zawartosc substancji rozpuszczonych\nZakres (100 – 75 000) mg/kg\nMetoda wagowa PB-13 wydanie 5 z dnia 22.02.2024 r. | PN-EN 12457-2:2006","categories":["water","environment","construction"],"row_index":109,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissolved solids content","parameters_en":[{"name":"Range","range":"(100 – 75 000) mg/kg"}],"search_en":"Dissolved solids content Gravimetric method Range PB-13 wydanie 5 z dnia 22.02.2024 r. | PN-EN 12457-2:2006","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(100 – 75 000) mg/kg"}],"search_zh":"溶解性物质含量 重量法 范围 PB-13 wydanie 5 z dnia 22.02.2024 r. | PN-EN 12457-2:2006","technique_zh":"重量法","methodology_zh":"溶解性物质含量"},{"_id":"6a837952af14b9c0e7b1fca4","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"OdpadyDAB-11: Osady i odpady mineralne (I), Odpady budowlane (III), Osady z procesów przemysłowych (VII), Odpady z oczyszczania gazów odlotowych (X), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV);, OdpadyO) kod: 02 03 80, 04 02 21, 19 09 99","methodology":"Zawartość anionów","parameters":[{"name":"Fluorki","range":"(1,0 – 1000) mg/kg"},{"name":"Chlorki","range":"(50 – 50 000) mg/kg"},{"name":"Siarczany","range":"(50 – 10 000) mg/kg"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Zawartość anionów\nZakres:\nFluorki (1,0 – 1000) mg/kg\nChlorki (50 – 50 000) mg/kg\nSiarczany (50 – 10 000) mg/kg\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012 | PN-EN 12457-2:2006","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012","PN-EN 12457-2:2006"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz.U. 2015 poz. 1277)\nDAB-11) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grup walidacyjnych podano w Załączniku nr 1 do DAB-11\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"OdpadyDAB-11: Osady i odpady mineralne (I), Odpady budowlane (III), Osady z procesów przemysłowych (VII), Odpady z oczyszczania gazów odlotowych (X), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV);, OdpadyO) kod: 02 03 80, 04 02 21, 19 09 99 Zawartość anionów\nZakres:\nFluorki (1,0 – 1000) mg/kg\nChlorki (50 – 50 000) mg/kg\nSiarczany (50 – 10 000) mg/kg\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 | PN-EN 12457-2:2006 OdpadyDAB-11: Osady i odpady mineralne (I), Odpady budowlane (III), Osady z procesow przemyslowych (VII), Odpady z oczyszczania gazow odlotowych (X), Zuzle, popioly i pyly paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV);, OdpadyO) kod: 02 03 80, 04 02 21, 19 09 99 Zawartosc anionow\nZakres:\nFluorki (1,0 – 1000) mg/kg\nChlorki (50 – 50 000) mg/kg\nSiarczany (50 – 10 000) mg/kg\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 | PN-EN 12457-2:2006","categories":["water","environment","construction"],"row_index":110,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Anion content","parameters_en":[{"name":"Fluorides","range":"(1,0 – 1000) mg/kg"},{"name":"Chlorides","range":"(50 – 50 000) mg/kg"},{"name":"Sulfates","range":"(50 – 10 000) mg/kg"}],"search_en":"Anion content Ion chromatography with conductometric detection (IC-CD) Fluorides Chlorides Sulfates PN-EN ISO 10304-1:2009+AC:2012 | PN-EN 12457-2:2006","technique_en":"Ion chromatography with conductometric detection (IC-CD)","parameters_zh":[{"name":"氟化物","range":"(1,0 – 1000) mg/kg"},{"name":"氯化物","range":"(50 – 50 000) mg/kg"},{"name":"硫酸盐","range":"(50 – 10 000) mg/kg"}],"search_zh":"阴离子含量 离子色谱-电导检测法（IC-CD） 氟化物 氯化物 硫酸盐 PN-EN ISO 10304-1:2009+AC:2012 | PN-EN 12457-2:2006","technique_zh":"离子色谱-电导检测法（IC-CD）","methodology_zh":"阴离子含量"},{"_id":"6a837952af14b9c0e7b1fca5","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"OdpadyDAB-11: Osady i odpady mineralne (I), Odpady budowlane (III), Osady z procesów przemysłowych (VII), Odpady z oczyszczania gazów odlotowych (X), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV);, OdpadyO) kod: 02 03 80, 04 02 21, 19 09 99","methodology":"Zawartość rtęci","parameters":[{"name":"Zakres","range":"(0,005– 200) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","techniques":["Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji"],"computed":[],"activity":"Zawartość rtęci\nZakres (0,005– 200) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","reference":"PB–21 wydanie 8 z dnia 30.03.2026 r | PN-EN 12457-2:2006","norm_bases":["PB–21 wydanie 8 z dnia 30.03.2026 r","PN-EN 12457-2:2006"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz.U. 2015 poz. 1277)\nDAB-11) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grup walidacyjnych podano w Załączniku nr 1 do DAB-11\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"OdpadyDAB-11: Osady i odpady mineralne (I), Odpady budowlane (III), Osady z procesów przemysłowych (VII), Odpady z oczyszczania gazów odlotowych (X), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV);, OdpadyO) kod: 02 03 80, 04 02 21, 19 09 99 Zawartość rtęci\nZakres (0,005– 200) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji PB–21 wydanie 8 z dnia 30.03.2026 r | PN-EN 12457-2:2006 OdpadyDAB-11: Osady i odpady mineralne (I), Odpady budowlane (III), Osady z procesow przemyslowych (VII), Odpady z oczyszczania gazow odlotowych (X), Zuzle, popioly i pyly paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV);, OdpadyO) kod: 02 03 80, 04 02 21, 19 09 99 Zawartosc rteci\nZakres (0,005– 200) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z technika amalgamacji PB–21 wydanie 8 z dnia 30.03.2026 r | PN-EN 12457-2:2006","categories":["water","environment","construction"],"row_index":111,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury content","parameters_en":[{"name":"Range","range":"(0,005– 200) mg/kg"}],"search_en":"Mercury content Atomic absorption spectrometry with amalgamation technique Range PB–21 wydanie 8 z dnia 30.03.2026 r | PN-EN 12457-2:2006","technique_en":"Atomic absorption spectrometry with amalgamation technique","methodology_zh":"汞含量","parameters_zh":[{"name":"范围","range":"(0,005– 200) mg/kg"}],"search_zh":"汞含量 原子吸收光谱法（汞齐化技术） 范围 PB–21 wydanie 8 z dnia 30.03.2026 r | PN-EN 12457-2:2006","technique_zh":"原子吸收光谱法（汞齐化技术）"},{"_id":"6a837952af14b9c0e7b1fca6","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"OdpadyDAB-11: Osady i odpady mineralne (I), Odpady budowlane (III), Osady z procesów przemysłowych (VII), Odpady z oczyszczania gazów odlotowych (X), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV);, OdpadyO) kod: 02 03 80, 04 02 21, 19 09 99","methodology":"Zawartość rozpuszczonego węgla organicznego (DOC)","parameters":[{"name":"Zakres","range":"(40 – 5000) mg/kg"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość rozpuszczonego węgla organicznego (DOC)\nZakres (40 – 5000) mg/kg\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN 1484:1999 | PN-EN 12457-2:2006","norm_bases":["PN-EN 1484:1999","PN-EN 12457-2:2006"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz.U. 2015 poz. 1277)\nDAB-11) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grup walidacyjnych podano w Załączniku nr 1 do DAB-11\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"OdpadyDAB-11: Osady i odpady mineralne (I), Odpady budowlane (III), Osady z procesów przemysłowych (VII), Odpady z oczyszczania gazów odlotowych (X), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV);, OdpadyO) kod: 02 03 80, 04 02 21, 19 09 99 Zawartość rozpuszczonego węgla organicznego (DOC)\nZakres (40 – 5000) mg/kg\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN 1484:1999 | PN-EN 12457-2:2006 OdpadyDAB-11: Osady i odpady mineralne (I), Odpady budowlane (III), Osady z procesow przemyslowych (VII), Odpady z oczyszczania gazow odlotowych (X), Zuzle, popioly i pyly paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV);, OdpadyO) kod: 02 03 80, 04 02 21, 19 09 99 Zawartosc rozpuszczonego wegla organicznego (DOC)\nZakres (40 – 5000) mg/kg\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN 1484:1999 | PN-EN 12457-2:2006","categories":["water","environment","construction"],"row_index":112,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissolved organic carbon (DOC) content","parameters_en":[{"name":"Range","range":"(40 – 5000) mg/kg"}],"search_en":"Dissolved organic carbon (DOC) content High-temperature combustion with IR detection Range PN-EN 1484:1999 | PN-EN 12457-2:2006","technique_en":"High-temperature combustion with IR detection","parameters_zh":[{"name":"范围","range":"(40 – 5000) mg/kg"}],"search_zh":"溶解性有机碳（DOC）含量 高温燃烧红外检测法 范围 PN-EN 1484:1999 | PN-EN 12457-2:2006","technique_zh":"高温燃烧红外检测法","methodology_zh":"溶解性有机碳（DOC）含量"},{"_id":"6a837952af14b9c0e7b1fca7","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"OdpadyDAB-11: Osady i odpady mineralne (I), Odpady budowlane (III), Osady z procesów przemysłowych (VII), Odpady z oczyszczania gazów odlotowych (X), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV);, OdpadyO) kod: 02 03 80, 04 02 21, 19 09 99","methodology":"Zawartość metali","parameters":[{"name":"Pb","range":"(0,05 – 1000) mg/kg"},{"name":"Cu","range":"(0,06 – 1000) mg/kg"},{"name":"Zn","range":"(0,22 – 5000) mg/kg"},{"name":"Ni","range":"(0,05 – 1000) mg/kg"},{"name":"Cd","range":"(0,005 – 1000) mg/kg"},{"name":"Cr","range":"(0,05 – 1000) mg/kg"},{"name":"Ba","range":"(0,01 – 1000) mg/kg"},{"name":"Mo","range":"(0,08 – 1000) mg/kg"}],"technique":"Metoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość metali\nZakres:\nPb (0,05 – 1000) mg/kg\nCu (0,06 – 1000) mg/kg\nZn (0,22 – 5000) mg/kg\nNi (0,05 – 1000) mg/kg\nCd (0,005 – 1000) mg/kg\nCr (0,05 – 1000) mg/kg\nBa (0,01 – 1000) mg/kg\nMo (0,08 – 1000) mg/kg\nMetoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009 | PN-EN 12457-2:2006","norm_bases":["PN-EN ISO 11885:2009","PN-EN 12457-2:2006"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz.U. 2015 poz. 1277)\nDAB-11) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grup walidacyjnych podano w Załączniku nr 1 do DAB-11\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"OdpadyDAB-11: Osady i odpady mineralne (I), Odpady budowlane (III), Osady z procesów przemysłowych (VII), Odpady z oczyszczania gazów odlotowych (X), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV);, OdpadyO) kod: 02 03 80, 04 02 21, 19 09 99 Zawartość metali\nZakres:\nPb (0,05 – 1000) mg/kg\nCu (0,06 – 1000) mg/kg\nZn (0,22 – 5000) mg/kg\nNi (0,05 – 1000) mg/kg\nCd (0,005 – 1000) mg/kg\nCr (0,05 – 1000) mg/kg\nBa (0,01 – 1000) mg/kg\nMo (0,08 – 1000) mg/kg\nMetoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 | PN-EN 12457-2:2006 OdpadyDAB-11: Osady i odpady mineralne (I), Odpady budowlane (III), Osady z procesow przemyslowych (VII), Odpady z oczyszczania gazow odlotowych (X), Zuzle, popioly i pyly paleniskowe (XI), Odpady chemiczne – organiczne zmieszane (XIV);, OdpadyO) kod: 02 03 80, 04 02 21, 19 09 99 Zawartosc metali\nZakres:\nPb (0,05 – 1000) mg/kg\nCu (0,06 – 1000) mg/kg\nZn (0,22 – 5000) mg/kg\nNi (0,05 – 1000) mg/kg\nCd (0,005 – 1000) mg/kg\nCr (0,05 – 1000) mg/kg\nBa (0,01 – 1000) mg/kg\nMo (0,08 – 1000) mg/kg\nMetoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009 | PN-EN 12457-2:2006","categories":["water","materials","environment","construction"],"row_index":113,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Metal content","parameters_en":[{"name":"Pb","range":"(0,05 – 1000) mg/kg"},{"name":"Cu","range":"(0,06 – 1000) mg/kg"},{"name":"Zn","range":"(0,22 – 5000) mg/kg"},{"name":"Ni","range":"(0,05 – 1000) mg/kg"},{"name":"Cd","range":"(0,005 – 1000) mg/kg"},{"name":"Cr","range":"(0,05 – 1000) mg/kg"},{"name":"Ba","range":"(0,01 – 1000) mg/kg"},{"name":"Mo","range":"(0,08 – 1000) mg/kg"}],"search_en":"Metal content Inductively coupled plasma optical emission spectrometry (ICP-OES) Pb Cu Zn Ni Cd Cr Ba Mo PN-EN ISO 11885:2009 | PN-EN 12457-2:2006","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","parameters_zh":[{"name":"Pb","range":"(0,05 – 1000) mg/kg"},{"name":"Cu","range":"(0,06 – 1000) mg/kg"},{"name":"Zn","range":"(0,22 – 5000) mg/kg"},{"name":"Ni","range":"(0,05 – 1000) mg/kg"},{"name":"Cd","range":"(0,005 – 1000) mg/kg"},{"name":"Cr","range":"(0,05 – 1000) mg/kg"},{"name":"Ba","range":"(0,01 – 1000) mg/kg"},{"name":"Mo","range":"(0,08 – 1000) mg/kg"}],"search_zh":"金属含量 电感耦合等离子体发射光谱法（ICP-OES） Pb Cu Zn Ni Cd Cr Ba Mo PN-EN ISO 11885:2009 | PN-EN 12457-2:2006","methodology_zh":"金属含量","technique_zh":"电感耦合等离子体发射光谱法（ICP-OES）"},{"_id":"6a837952af14b9c0e7b1fca8","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"OdpadyDAB-11: Odpady budowlane (III), Odpady z oczyszczania gazów odlotowych (X), Żużle, popioły i pyły paleniskowe (XI)","methodology":"Zawartość metali","parameters":[{"name":"As","range":"(0,03 – 1000) mg/kg"},{"name":"Se","range":"(0,03 – 1000) mg/kg"},{"name":"Sb","range":"(0,04 – 1000) mg/kg"}],"technique":"Metoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość metali\nZakres:\nAs (0,03 – 1000) mg/kg\nSe (0,03 – 1000) mg/kg\nSb (0,04 – 1000) mg/kg\nMetoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009 | PN-EN 12457-2:2006","norm_bases":["PN-EN ISO 11885:2009","PN-EN 12457-2:2006"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz.U. 2015 poz. 1277)\nDAB-11) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grup walidacyjnych podano w Załączniku nr 1 do DAB-11\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"OdpadyDAB-11: Odpady budowlane (III), Odpady z oczyszczania gazów odlotowych (X), Żużle, popioły i pyły paleniskowe (XI) Zawartość metali\nZakres:\nAs (0,03 – 1000) mg/kg\nSe (0,03 – 1000) mg/kg\nSb (0,04 – 1000) mg/kg\nMetoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 | PN-EN 12457-2:2006 OdpadyDAB-11: Odpady budowlane (III), Odpady z oczyszczania gazow odlotowych (X), Zuzle, popioly i pyly paleniskowe (XI) Zawartosc metali\nZakres:\nAs (0,03 – 1000) mg/kg\nSe (0,03 – 1000) mg/kg\nSb (0,04 – 1000) mg/kg\nMetoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009 | PN-EN 12457-2:2006","categories":["materials","environment","construction"],"row_index":114,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Metal content","parameters_en":[{"name":"As","range":"(0,03 – 1000) mg/kg"},{"name":"Se","range":"(0,03 – 1000) mg/kg"},{"name":"Sb","range":"(0,04 – 1000) mg/kg"}],"search_en":"Metal content Inductively coupled plasma optical emission spectrometry (ICP-OES) As Se Sb PN-EN ISO 11885:2009 | PN-EN 12457-2:2006","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","methodology_zh":"金属含量","parameters_zh":[{"name":"As","range":"(0,03 – 1000) mg/kg"},{"name":"Se","range":"(0,03 – 1000) mg/kg"},{"name":"Sb","range":"(0,04 – 1000) mg/kg"}],"search_zh":"金属含量 电感耦合等离子体发射光谱法（ICP-OES） As Se Sb PN-EN ISO 11885:2009 | PN-EN 12457-2:2006","technique_zh":"电感耦合等离子体发射光谱法（ICP-OES）"},{"_id":"6a837952af14b9c0e7b1fca9","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"OdpadyO) kod: 10 01 01, 10 01 02, 10 01 05, 10 01 21, 19 09 05, 10 01 80","methodology":"Zdolność do neutralizacji kwasów ANC (siła zobojętniająca)","parameters":[{"name":"Zakres","range":"(2,0 – 400) mmol/kg"}],"technique":"Metoda miareczkowa; Metoda miareczkowania potencjometrycznego","techniques":["Metoda miareczkowa","Metoda miareczkowania potencjometrycznego"],"computed":[],"activity":"Zdolność do neutralizacji kwasów ANC (siła zobojętniająca)\nZakres (2,0 – 400) mmol/kg\nMetoda miareczkowa; Metoda miareczkowania potencjometrycznego","reference":"PN-EN ISO 9963-1:2001+Ap1:2004 | PN-EN 12457-2:2006","norm_bases":["PN-EN ISO 9963-1:2001+Ap1:2004","PN-EN 12457-2:2006"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz.U. 2015 poz. 1277)\nDAB-11) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grup walidacyjnych podano w Załączniku nr 1 do DAB-11\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"OdpadyO) kod: 10 01 01, 10 01 02, 10 01 05, 10 01 21, 19 09 05, 10 01 80 Zdolność do neutralizacji kwasów ANC (siła zobojętniająca)\nZakres (2,0 – 400) mmol/kg\nMetoda miareczkowa; Metoda miareczkowania potencjometrycznego PN-EN ISO 9963-1:2001+Ap1:2004 | PN-EN 12457-2:2006 OdpadyO) kod: 10 01 01, 10 01 02, 10 01 05, 10 01 21, 19 09 05, 10 01 80 Zdolnosc do neutralizacji kwasow ANC (sila zobojetniajaca)\nZakres (2,0 – 400) mmol/kg\nMetoda miareczkowa; Metoda miareczkowania potencjometrycznego PN-EN ISO 9963-1:2001+Ap1:2004 | PN-EN 12457-2:2006","categories":["environment"],"row_index":115,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Acid neutralization capacity ANC (neutralizing power)","parameters_en":[{"name":"Range","range":"(2,0 – 400) mmol/kg"}],"search_en":"Acid neutralization capacity ANC (neutralizing power) Titrimetric method; Potentiometric titration method Range PN-EN ISO 9963-1:2001+Ap1:2004 | PN-EN 12457-2:2006","technique_en":"Titrimetric method; Potentiometric titration method","parameters_zh":[{"name":"范围","range":"(2,0 – 400) mmol/kg"}],"search_zh":"范围 PN-EN ISO 9963-1:2001+Ap1:2004 | PN-EN 12457-2:2006"},{"_id":"6a837952af14b9c0e7b1fcaa","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"OdpadyO): kod 17 05 04, 17 05 05*, 17 05 06, 17 08 01*, 17 08 02, 17 01 81, 01 05 05*, 01 05 08, 06 05 02 *, 06 05 03","methodology":"Zawartość węglowodorów w zakresie C10 do C40 (oleje mineralne)","parameters":[{"name":"Zakres","range":"(5,0 – 10 000) mg/ kg"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość węglowodorów w zakresie C10 do C40 (oleje mineralne)\nZakres (5,0 – 10 000) mg/ kg\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 14039:2008","norm_bases":["PN-EN 14039:2008"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz.U. 2015 poz. 1277)\nDAB-11) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grup walidacyjnych podano w Załączniku nr 1 do DAB-11\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"OdpadyO): kod 17 05 04, 17 05 05*, 17 05 06, 17 08 01*, 17 08 02, 17 01 81, 01 05 05*, 01 05 08, 06 05 02 *, 06 05 03 Zawartość węglowodorów w zakresie C10 do C40 (oleje mineralne)\nZakres (5,0 – 10 000) mg/ kg\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 14039:2008 OdpadyO): kod 17 05 04, 17 05 05*, 17 05 06, 17 08 01*, 17 08 02, 17 01 81, 01 05 05*, 01 05 08, 06 05 02 *, 06 05 03 Zawartosc weglowodorow w zakresie C10 do C40 (oleje mineralne)\nZakres (5,0 – 10 000) mg/ kg\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 14039:2008","categories":["environment","petro"],"row_index":116,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of hydrocarbons in the range C10 to C40 (mineral oils)","parameters_en":[{"name":"Range","range":"(5,0 – 10 000) mg/ kg"}],"search_en":"Content of hydrocarbons in the range C10 to C40 (mineral oils) Gas chromatography with flame ionization detection (GC-FID) Range PN-EN 14039:2008","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","parameters_zh":[{"name":"范围","range":"(5,0 – 10 000) mg/ kg"}],"search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-EN 14039:2008","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a837952af14b9c0e7b1fcab","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"OdpadyDAB-11: Osady i odpady mineralne (I), Odpady budowlane (III), Osady z procesów przemysłowych (VII);, Żużle, popioły i pyły paleniskowe (XI);, OdpadyO) kod: 10 01 05, 19 09 05, 19 09 99","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 13,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 13,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego:\n- Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz.U. 2015 poz. 1277)\n- Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (Dz.U. 2015 poz. 257 z późn. zm.)\n- Rozporządzeniem Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz.U. 2015 poz. 132)\nDAB-11) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grup walidacyjnych podano w Załączniku nr 1 do DAB-11\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"OdpadyDAB-11: Osady i odpady mineralne (I), Odpady budowlane (III), Osady z procesów przemysłowych (VII);, Żużle, popioły i pyły paleniskowe (XI);, OdpadyO) kod: 10 01 05, 19 09 05, 19 09 99 pH\nZakres 2,0 – 13,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 OdpadyDAB-11: Osady i odpady mineralne (I), Odpady budowlane (III), Osady z procesow przemyslowych (VII);, Zuzle, popioly i pyly paleniskowe (XI);, OdpadyO) kod: 10 01 05, 19 09 05, 19 09 99 pH\nZakres 2,0 – 13,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["water","environment","construction"],"row_index":117,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 – 13,0"}],"search_en":"pH Potentiometric method Range PN-EN ISO 10390:2022-09","technique_en":"Potentiometric method","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 13,0"}],"search_zh":"pH 值 电位法 范围 PN-EN ISO 10390:2022-09","technique_zh":"电位法"},{"_id":"6a837952af14b9c0e7b1fcac","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"OdpadyDAB-11: Osady i odpady mineralne (I), Odpady budowlane (III), Osady z procesów przemysłowych (VII);, Żużle, popioły i pyły paleniskowe (XI);, OdpadyO) kod: 10 01 05, 19 09 05, 19 09 99","methodology":"Sucha masa / zawartość wody","parameters":[{"name":"Zakres","range":"(0,5 – 99,9)%"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha masa / zawartość wody\nZakres (0,5 – 99,9)%\nMetoda wagowa","reference":"PN-EN ISO 11465:2026-03","norm_bases":["PN-EN ISO 11465:2026-03"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego:\n- Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz.U. 2015 poz. 1277)\n- Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (Dz.U. 2015 poz. 257 z późn. zm.)\n- Rozporządzeniem Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz.U. 2015 poz. 132)\nDAB-11) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grup walidacyjnych podano w Załączniku nr 1 do DAB-11\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"OdpadyDAB-11: Osady i odpady mineralne (I), Odpady budowlane (III), Osady z procesów przemysłowych (VII);, Żużle, popioły i pyły paleniskowe (XI);, OdpadyO) kod: 10 01 05, 19 09 05, 19 09 99 Sucha masa / zawartość wody\nZakres (0,5 – 99,9)%\nMetoda wagowa PN-EN ISO 11465:2026-03 OdpadyDAB-11: Osady i odpady mineralne (I), Odpady budowlane (III), Osady z procesow przemyslowych (VII);, Zuzle, popioly i pyly paleniskowe (XI);, OdpadyO) kod: 10 01 05, 19 09 05, 19 09 99 Sucha masa / zawartosc wody\nZakres (0,5 – 99,9)%\nMetoda wagowa PN-EN ISO 11465:2026-03","categories":["water","environment","construction"],"row_index":118,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry matter / water content","parameters_en":[{"name":"Range","range":"(0,5 – 99,9)%"}],"search_en":"Dry matter / water content Gravimetric method Range PN-EN ISO 11465:2026-03","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(0,5 – 99,9)%"}],"search_zh":"干物质 / 水分含量 重量法 范围 PN-EN ISO 11465:2026-03","technique_zh":"重量法","methodology_zh":"干物质 / 水分含量"},{"_id":"6a837952af14b9c0e7b1fcad","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"OdpadyDAB-11: Osady i odpady mineralne (I), Odpady budowlane (III), Osady z procesów przemysłowych (VII);, Żużle, popioły i pyły paleniskowe (XI);, OdpadyO) kod: 10 01 05, 19 09 05, 19 09 99","methodology":"Straty przy prażeniu suchej masy (LOI)","parameters":[{"name":"Zakres","range":"(0,1 – 99,9)%"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Straty przy prażeniu suchej masy (LOI)\nZakres (0,1 – 99,9)%\nMetoda wagowa","reference":"PN-EN 15935:2022-01","norm_bases":["PN-EN 15935:2022-01"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego:\n- Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz.U. 2015 poz. 1277)\n- Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (Dz.U. 2015 poz. 257 z późn. zm.)\n- Rozporządzeniem Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz.U. 2015 poz. 132)\nDAB-11) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grup walidacyjnych podano w Załączniku nr 1 do DAB-11\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"OdpadyDAB-11: Osady i odpady mineralne (I), Odpady budowlane (III), Osady z procesów przemysłowych (VII);, Żużle, popioły i pyły paleniskowe (XI);, OdpadyO) kod: 10 01 05, 19 09 05, 19 09 99 Straty przy prażeniu suchej masy (LOI)\nZakres (0,1 – 99,9)%\nMetoda wagowa PN-EN 15935:2022-01 OdpadyDAB-11: Osady i odpady mineralne (I), Odpady budowlane (III), Osady z procesow przemyslowych (VII);, Zuzle, popioly i pyly paleniskowe (XI);, OdpadyO) kod: 10 01 05, 19 09 05, 19 09 99 Straty przy prazeniu suchej masy (LOI)\nZakres (0,1 – 99,9)%\nMetoda wagowa PN-EN 15935:2022-01","categories":["water","environment","construction"],"row_index":119,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Loss on ignition of dry matter (LOI)","parameters_en":[{"name":"Range","range":"(0,1 – 99,9)%"}],"search_en":"Loss on ignition of dry matter (LOI) Gravimetric method Range PN-EN 15935:2022-01","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(0,1 – 99,9)%"}],"search_zh":"干物质烧失量（LOI） 重量法 范围 PN-EN 15935:2022-01","technique_zh":"重量法","methodology_zh":"干物质烧失量（LOI）"},{"_id":"6a837952af14b9c0e7b1fcae","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Grunty, Osady denne, Osady ściekowe, Odpady O) kod: 01 05 08, 01 05 05*, 17 05 05*, 17 05 06","methodology":"Zawartość BTEX","parameters":[{"name":"Benzen","range":"(0,05 – 300) mg/kg"},{"name":"Etylobenzen","range":"(0,05 – 300) mg/kg"},{"name":"Toluen","range":"(0,05 – 300) mg/kg"},{"name":"m+p-Ksylen","range":"(0,10 – 300) mg/kg"},{"name":"o-Ksylen","range":"(0,05 – 300) mg/kg"},{"name":"Styren","range":"(0,05 – 300) mg/kg"}],"technique":"Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)","techniques":["Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)"],"computed":[],"activity":"Zawartość BTEX\nZakres:\nBenzen (0,05 – 300) mg/kg\nEtylobenzen (0,05 – 300) mg/kg\nToluen (0,05 – 300) mg/kg\nm+p-Ksylen (0,10 – 300) mg/kg\no-Ksylen (0,05 – 300) mg/kg\nStyren (0,05 – 300) mg/kg\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)","reference":"PN-EN ISO 22155:2016-07","norm_bases":["PN-EN ISO 22155:2016-07"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":"O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Grunty, Osady denne, Osady ściekowe, Odpady O) kod: 01 05 08, 01 05 05*, 17 05 05*, 17 05 06 Zawartość BTEX\nZakres:\nBenzen (0,05 – 300) mg/kg\nEtylobenzen (0,05 – 300) mg/kg\nToluen (0,05 – 300) mg/kg\nm+p-Ksylen (0,10 – 300) mg/kg\no-Ksylen (0,05 – 300) mg/kg\nStyren (0,05 – 300) mg/kg\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS) PN-EN ISO 22155:2016-07 Grunty, Osady denne, Osady sciekowe, Odpady O) kod: 01 05 08, 01 05 05*, 17 05 05*, 17 05 06 Zawartosc BTEX\nZakres:\nBenzen (0,05 – 300) mg/kg\nEtylobenzen (0,05 – 300) mg/kg\nToluen (0,05 – 300) mg/kg\nm+p-Ksylen (0,10 – 300) mg/kg\no-Ksylen (0,05 – 300) mg/kg\nStyren (0,05 – 300) mg/kg\nMetoda chromatografii gazowej z analiza fazy nadpowierzchniowej i detekcja spektrometria mas (HS-GC-MS) PN-EN ISO 22155:2016-07","categories":["water","environment"],"row_index":120,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"BTEX content","parameters_en":[{"name":"Benzene","range":"(0,05 – 300) mg/kg"},{"name":"Ethylbenzene","range":"(0,05 – 300) mg/kg"},{"name":"Toluene","range":"(0,05 – 300) mg/kg"},{"name":"m+p-Xylene","range":"(0,10 – 300) mg/kg"},{"name":"o-Xylene","range":"(0,05 – 300) mg/kg"},{"name":"Styrene","range":"(0,05 – 300) mg/kg"}],"search_en":"BTEX content Headspace gas chromatography with mass spectrometry detection (HS-GC-MS) Benzene Ethylbenzene Toluene m+p-Xylene o-Xylene Styrene PN-EN ISO 22155:2016-07","technique_en":"Headspace gas chromatography with mass spectrometry detection (HS-GC-MS)","search_zh":"顶空气相色谱-质谱法（HS-GC-MS） 苯 乙苯 甲苯 邻二甲苯 苯乙烯 PN-EN ISO 22155:2016-07","technique_zh":"顶空气相色谱-质谱法（HS-GC-MS）","parameters_zh":[{"name":"苯","range":"(0,05 – 300) mg/kg"},{"name":"乙苯","range":"(0,05 – 300) mg/kg"},{"name":"甲苯","range":"(0,05 – 300) mg/kg"},{"name":"m+p-Ksylen","range":"(0,10 – 300) mg/kg"},{"name":"邻二甲苯","range":"(0,05 – 300) mg/kg"},{"name":"苯乙烯","range":"(0,05 – 300) mg/kg"}]},{"_id":"6a837952af14b9c0e7b1fcaf","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Grunty, Osady denne, Osady ściekowe, Odpady O) kod: 01 05 08, 01 05 05*, 17 05 05*, 17 05 06","methodology":"Suma BTEX i BTX (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma BTEX i BTX (z obliczeń)","reference":"I-24 wydanie 3 z dnia 26.02.2024 r.","norm_bases":["I-24 wydanie 3 z dnia 26.02.2024 r."],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":"O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Grunty, Osady denne, Osady ściekowe, Odpady O) kod: 01 05 08, 01 05 05*, 17 05 05*, 17 05 06 Suma BTEX i BTX (z obliczeń) I-24 wydanie 3 z dnia 26.02.2024 r. Grunty, Osady denne, Osady sciekowe, Odpady O) kod: 01 05 08, 01 05 05*, 17 05 05*, 17 05 06 Suma BTEX i BTX (z obliczen) I-24 wydanie 3 z dnia 26.02.2024 r.","categories":["water","environment"],"row_index":121,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of BTEX and BTX (calculated)","search_en":"Sum of BTEX and BTX (calculated) I-24 wydanie 3 z dnia 26.02.2024 r."},{"_id":"6a837952af14b9c0e7b1fcb0","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Grunty, Osady denne, Osady ściekowe, Odpady O) kod: 17 05 05*, 17 05 06","methodology":"Zawartość węgla: Całkowity węgiel organiczny (TOC)","parameters":[{"name":"Zakres","range":"(1,0 – 400) g/kg"},{"name":"Całkowity węgiel (TC)"},{"name":"Zakres","range":"(1,0 – 400) g/kg"},{"name":"Węgiel nieorganiczny (IC)"},{"name":"Zakres","range":"(1,0 – 120) g/kg"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość węgla: Całkowity węgiel organiczny (TOC)\nZakres:\nZakres (1,0 – 400) g/kg\nCałkowity węgiel (TC)\nZakres (1,0 – 400) g/kg\nWęgiel nieorganiczny (IC)\nZakres (1,0 – 120) g/kg\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN - ISO 10694:2002 | PN-EN 13137:2004","norm_bases":["PN - ISO 10694:2002","PN-EN 13137:2004"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":"O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Grunty, Osady denne, Osady ściekowe, Odpady O) kod: 17 05 05*, 17 05 06 Zawartość węgla: Całkowity węgiel organiczny (TOC)\nZakres:\nZakres (1,0 – 400) g/kg\nCałkowity węgiel (TC)\nZakres (1,0 – 400) g/kg\nWęgiel nieorganiczny (IC)\nZakres (1,0 – 120) g/kg\nMetoda wysokotemperaturowego spalania z detekcją IR PN - ISO 10694:2002 | PN-EN 13137:2004 Grunty, Osady denne, Osady sciekowe, Odpady O) kod: 17 05 05*, 17 05 06 Zawartosc wegla: Calkowity wegiel organiczny (TOC)\nZakres:\nZakres (1,0 – 400) g/kg\nCalkowity wegiel (TC)\nZakres (1,0 – 400) g/kg\nWegiel nieorganiczny (IC)\nZakres (1,0 – 120) g/kg\nMetoda wysokotemperaturowego spalania z detekcja IR PN - ISO 10694:2002 | PN-EN 13137:2004","categories":["water","environment"],"row_index":122,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Carbon content: Total organic carbon (TOC)","parameters_en":[{"name":"Range","range":"(1,0 – 400) g/kg"},{"name":"Total carbon (TC)"},{"name":"Range","range":"(1,0 – 400) g/kg"},{"name":"Inorganic carbon (IC)"},{"name":"Range","range":"(1,0 – 120) g/kg"}],"search_en":"Carbon content: Total organic carbon (TOC) High-temperature combustion with IR detection Range Total carbon (TC) Range Inorganic carbon (IC) Range PN - ISO 10694:2002 | PN-EN 13137:2004","technique_en":"High-temperature combustion with IR detection","parameters_zh":[{"name":"范围","range":"(1,0 – 400) g/kg"},{"name":"Całkowity węgiel (TC)"},{"name":"范围","range":"(1,0 – 400) g/kg"},{"name":"Węgiel nieorganiczny (IC)"},{"name":"范围","range":"(1,0 – 120) g/kg"}],"search_zh":"高温燃烧红外检测法 范围 范围 范围 PN - ISO 10694:2002 | PN-EN 13137:2004","technique_zh":"高温燃烧红外检测法"},{"_id":"6a837952af14b9c0e7b1fcb1","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Grunty, Osady denne, Osady ściekowe, Odpady O) kod: 17 05 05*, 17 05 06","methodology":"Zawartość polichlorowanych bifenyli (PCB)","parameters":[{"name":"PCB 28","range":"(0,1 – 50) μg/kg"},{"name":"PCB 52","range":"(0,1 – 50) μg/kg"},{"name":"PCB 101","range":"(0,1 – 50) μg/kg"},{"name":"PCB 118","range":"(0,1 – 50) μg/kg"},{"name":"PCB 138","range":"(0,1 – 50) μg/kg"},{"name":"PCB 153","range":"(0,1 – 50) μg/kg"},{"name":"PCB 180","range":"(0,1 – 50) μg/kg"}],"technique":"Metoda chromatografii gazowej ze spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej ze spektrometrią mas (GC-MS)"],"computed":[],"activity":"Zawartość polichlorowanych bifenyli (PCB)\nZakres:\nPCB 28 (0,1 – 50) μg/kg\nPCB 52 (0,1 – 50) μg/kg\nPCB 101 (0,1 – 50) μg/kg\nPCB 118 (0,1 – 50) μg/kg\nPCB 138 (0,1 – 50) μg/kg\nPCB 153 (0,1 – 50) μg/kg\nPCB 180 (0,1 – 50) μg/kg\nMetoda chromatografii gazowej ze spektrometrią mas (GC-MS)","reference":"PB-09 wydanie 6 z dnia 22.02.2024 r.","norm_bases":["PB-09 wydanie 6 z dnia 22.02.2024 r."],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":"O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Grunty, Osady denne, Osady ściekowe, Odpady O) kod: 17 05 05*, 17 05 06 Zawartość polichlorowanych bifenyli (PCB)\nZakres:\nPCB 28 (0,1 – 50) μg/kg\nPCB 52 (0,1 – 50) μg/kg\nPCB 101 (0,1 – 50) μg/kg\nPCB 118 (0,1 – 50) μg/kg\nPCB 138 (0,1 – 50) μg/kg\nPCB 153 (0,1 – 50) μg/kg\nPCB 180 (0,1 – 50) μg/kg\nMetoda chromatografii gazowej ze spektrometrią mas (GC-MS) PB-09 wydanie 6 z dnia 22.02.2024 r. Grunty, Osady denne, Osady sciekowe, Odpady O) kod: 17 05 05*, 17 05 06 Zawartosc polichlorowanych bifenyli (PCB)\nZakres:\nPCB 28 (0,1 – 50) μg/kg\nPCB 52 (0,1 – 50) μg/kg\nPCB 101 (0,1 – 50) μg/kg\nPCB 118 (0,1 – 50) μg/kg\nPCB 138 (0,1 – 50) μg/kg\nPCB 153 (0,1 – 50) μg/kg\nPCB 180 (0,1 – 50) μg/kg\nMetoda chromatografii gazowej ze spektrometria mas (GC-MS) PB-09 wydanie 6 z dnia 22.02.2024 r.","categories":["water","environment"],"row_index":123,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Polychlorinated biphenyls (PCB) content","parameters_en":[{"name":"PCB 28","range":"(0,1 – 50) μg/kg"},{"name":"PCB 52","range":"(0,1 – 50) μg/kg"},{"name":"PCB 101","range":"(0,1 – 50) μg/kg"},{"name":"PCB 118","range":"(0,1 – 50) μg/kg"},{"name":"PCB 138","range":"(0,1 – 50) μg/kg"},{"name":"PCB 153","range":"(0,1 – 50) μg/kg"},{"name":"PCB 180","range":"(0,1 – 50) μg/kg"}],"search_en":"Polychlorinated biphenyls (PCB) content Gas chromatography with mass spectrometry (GC-MS) PCB 28 PCB 52 PCB 101 PCB 118 PCB 138 PCB 153 PCB 180 PB-09 wydanie 6 z dnia 22.02.2024 r.","technique_en":"Gas chromatography with mass spectrometry (GC-MS)","parameters_zh":[{"name":"PCB 28","range":"(0,1 – 50) μg/kg"},{"name":"PCB 52","range":"(0,1 – 50) μg/kg"},{"name":"PCB 101","range":"(0,1 – 50) μg/kg"},{"name":"PCB 118","range":"(0,1 – 50) μg/kg"},{"name":"PCB 138","range":"(0,1 – 50) μg/kg"},{"name":"PCB 153","range":"(0,1 – 50) μg/kg"},{"name":"PCB 180","range":"(0,1 – 50) μg/kg"}],"search_zh":"多氯联苯（PCB）含量 气相色谱-质谱法（GC-MS） PCB 28 PCB 52 PCB 101 PCB 118 PCB 138 PCB 153 PCB 180 PB-09 wydanie 6 z dnia 22.02.2024 r.","technique_zh":"气相色谱-质谱法（GC-MS）","methodology_zh":"多氯联苯（PCB）含量"},{"_id":"6a837952af14b9c0e7b1fcb2","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Grunty, Osady denne, Osady ściekowe, Odpady O) kod: 17 05 05*, 17 05 06","methodology":"Suma polichlorowanych bifenyli (PCB) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma polichlorowanych bifenyli (PCB) (z obliczeń)","reference":"I-24 wydanie 3 z dnia 26.02.2024 r.","norm_bases":["I-24 wydanie 3 z dnia 26.02.2024 r."],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":"O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Grunty, Osady denne, Osady ściekowe, Odpady O) kod: 17 05 05*, 17 05 06 Suma polichlorowanych bifenyli (PCB) (z obliczeń) I-24 wydanie 3 z dnia 26.02.2024 r. Grunty, Osady denne, Osady sciekowe, Odpady O) kod: 17 05 05*, 17 05 06 Suma polichlorowanych bifenyli (PCB) (z obliczen) I-24 wydanie 3 z dnia 26.02.2024 r.","categories":["water","environment"],"row_index":124,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of polychlorinated biphenyls (PCB) (calculated)","search_en":"Sum of polychlorinated biphenyls (PCB) (calculated) I-24 wydanie 3 z dnia 26.02.2024 r.","methodology_zh":"多氯联苯（PCB）总量（由计算得出）","search_zh":"多氯联苯（PCB）总量（由计算得出） I-24 wydanie 3 z dnia 26.02.2024 r."},{"_id":"6a837952af14b9c0e7b1fcb3","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Grunty, Osady denne, Osady ściekowe, Odpady O) kod: 17 05 05*, 17 05 06","methodology":"Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA)","parameters":[{"name":"Naftalen","range":"(0,001 – 1000) mg/kg"},{"name":"Acenaftylen","range":"(0,001 – 1000) mg/kg"},{"name":"Acenaften","range":"(0,001 – 1000) mg/kg"},{"name":"Fluoren","range":"(0,001 – 1000) mg/kg"},{"name":"Fenantren","range":"(0,001 – 1000) mg/kg"},{"name":"Antracen","range":"(0,001 – 1000) mg/kg"},{"name":"Fluoranten","range":"(0,001 – 1000) mg/kg"},{"name":"Piren","range":"(0,001 – 1000) mg/kg"},{"name":"Benzo(a)antracen"},{"name":"Zakres","range":"(0,001 – 1000) mg/kg"},{"name":"Chryzen","range":"(0,001 – 1000) mg/kg"},{"name":"Benzo(b)fluoranten","range":"(0,001 – 1000) mg/kg"},{"name":"Benzo(k)fluoranten","range":"(0,001 – 1000) mg/kg"},{"name":"Benzo(a)piren","range":"(0,001 – 1000) mg/kg"},{"name":"Indeno","range":"(1,2,3,-cd)piren"},{"name":"(0,001 – 1000) mg/kg"},{"name":"Dibenzo(a,h)antracen","range":"(0,001 – 1000) mg/kg"},{"name":"Benzo(g,h,i)perylen","range":"(0,001 – 1000) mg/kg"}],"technique":"Metoda chromatografii gazowej ze spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej ze spektrometrią mas (GC-MS)"],"computed":[],"activity":"Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA)\nZakres:\nNaftalen (0,001 – 1000) mg/kg\nAcenaftylen (0,001 – 1000) mg/kg\nAcenaften (0,001 – 1000) mg/kg\nFluoren (0,001 – 1000) mg/kg\nFenantren (0,001 – 1000) mg/kg\nAntracen (0,001 – 1000) mg/kg\nFluoranten (0,001 – 1000) mg/kg\nPiren (0,001 – 1000) mg/kg\nBenzo(a)antracen\nZakres (0,001 – 1000) mg/kg\nChryzen (0,001 – 1000) mg/kg\nBenzo(b)fluoranten (0,001 – 1000) mg/kg\nBenzo(k)fluoranten (0,001 – 1000) mg/kg\nBenzo(a)piren (0,001 – 1000) mg/kg\nIndeno (1,2,3,-cd)piren\n(0,001 – 1000) mg/kg\nDibenzo(a,h)antracen (0,001 – 1000) mg/kg\nBenzo(g,h,i)perylen (0,001 – 1000) mg/kg\nMetoda chromatografii gazowej ze spektrometrią mas (GC-MS)","reference":"PB-09 wydanie 6 z dnia 22.02.2024 r.","norm_bases":["PB-09 wydanie 6 z dnia 22.02.2024 r."],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":"O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Grunty, Osady denne, Osady ściekowe, Odpady O) kod: 17 05 05*, 17 05 06 Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA)\nZakres:\nNaftalen (0,001 – 1000) mg/kg\nAcenaftylen (0,001 – 1000) mg/kg\nAcenaften (0,001 – 1000) mg/kg\nFluoren (0,001 – 1000) mg/kg\nFenantren (0,001 – 1000) mg/kg\nAntracen (0,001 – 1000) mg/kg\nFluoranten (0,001 – 1000) mg/kg\nPiren (0,001 – 1000) mg/kg\nBenzo(a)antracen\nZakres (0,001 – 1000) mg/kg\nChryzen (0,001 – 1000) mg/kg\nBenzo(b)fluoranten (0,001 – 1000) mg/kg\nBenzo(k)fluoranten (0,001 – 1000) mg/kg\nBenzo(a)piren (0,001 – 1000) mg/kg\nIndeno (1,2,3,-cd)piren\n(0,001 – 1000) mg/kg\nDibenzo(a,h)antracen (0,001 – 1000) mg/kg\nBenzo(g,h,i)perylen (0,001 – 1000) mg/kg\nMetoda chromatografii gazowej ze spektrometrią mas (GC-MS) PB-09 wydanie 6 z dnia 22.02.2024 r. Grunty, Osady denne, Osady sciekowe, Odpady O) kod: 17 05 05*, 17 05 06 Zawartosc wielopierscieniowych weglowodorow aromatycznych (WWA)\nZakres:\nNaftalen (0,001 – 1000) mg/kg\nAcenaftylen (0,001 – 1000) mg/kg\nAcenaften (0,001 – 1000) mg/kg\nFluoren (0,001 – 1000) mg/kg\nFenantren (0,001 – 1000) mg/kg\nAntracen (0,001 – 1000) mg/kg\nFluoranten (0,001 – 1000) mg/kg\nPiren (0,001 – 1000) mg/kg\nBenzo(a)antracen\nZakres (0,001 – 1000) mg/kg\nChryzen (0,001 – 1000) mg/kg\nBenzo(b)fluoranten (0,001 – 1000) mg/kg\nBenzo(k)fluoranten (0,001 – 1000) mg/kg\nBenzo(a)piren (0,001 – 1000) mg/kg\nIndeno (1,2,3,-cd)piren\n(0,001 – 1000) mg/kg\nDibenzo(a,h)antracen (0,001 – 1000) mg/kg\nBenzo(g,h,i)perylen (0,001 – 1000) mg/kg\nMetoda chromatografii gazowej ze spektrometria mas (GC-MS) PB-09 wydanie 6 z dnia 22.02.2024 r.","categories":["water","environment"],"row_index":125,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Polycyclic aromatic hydrocarbons (PAH) content","parameters_en":[{"name":"Naphthalene","range":"(0,001 – 1000) mg/kg"},{"name":"Acenaphthylene","range":"(0,001 – 1000) mg/kg"},{"name":"Acenaphthene","range":"(0,001 – 1000) mg/kg"},{"name":"Fluorene","range":"(0,001 – 1000) mg/kg"},{"name":"Phenanthrene","range":"(0,001 – 1000) mg/kg"},{"name":"Anthracene","range":"(0,001 – 1000) mg/kg"},{"name":"Fluoranthene","range":"(0,001 – 1000) mg/kg"},{"name":"Pyrene","range":"(0,001 – 1000) mg/kg"},{"name":"Benzo(a)anthracene"},{"name":"Range","range":"(0,001 – 1000) mg/kg"},{"name":"Chrysene","range":"(0,001 – 1000) mg/kg"},{"name":"Benzo(b)fluoranthene","range":"(0,001 – 1000) mg/kg"},{"name":"Benzo(k)fluoranthene","range":"(0,001 – 1000) mg/kg"},{"name":"Benzo(a)pyrene","range":"(0,001 – 1000) mg/kg"},{"name":"Indeno","range":"(1,2,3,-cd)piren"},{"name":"(0,001 – 1000) mg/kg"},{"name":"Dibenzo(a,h)anthracene","range":"(0,001 – 1000) mg/kg"},{"name":"Benzo(g,h,i)perylene","range":"(0,001 – 1000) mg/kg"}],"search_en":"Polycyclic aromatic hydrocarbons (PAH) content Gas chromatography with mass spectrometry (GC-MS) Naphthalene Acenaphthylene Acenaphthene Fluorene Phenanthrene Anthracene Fluoranthene Pyrene Benzo(a)anthracene Range Chrysene Benzo(b)fluoranthene Benzo(k)fluoranthene Benzo(a)pyrene Indeno (0,001 – 1000) mg/kg Dibenzo(a,h)anthracene Benzo(g,h,i)perylene PB-09 wydanie 6 z dnia 22.02.2024 r.","technique_en":"Gas chromatography with mass spectrometry (GC-MS)","parameters_zh":[{"name":"萘","range":"(0,001 – 1000) mg/kg"},{"name":"苊烯","range":"(0,001 – 1000) mg/kg"},{"name":"苊","range":"(0,001 – 1000) mg/kg"},{"name":"芴","range":"(0,001 – 1000) mg/kg"},{"name":"菲","range":"(0,001 – 1000) mg/kg"},{"name":"蒽","range":"(0,001 – 1000) mg/kg"},{"name":"荧蒽","range":"(0,001 – 1000) mg/kg"},{"name":"芘","range":"(0,001 – 1000) mg/kg"},{"name":"苯并(a)蒽"},{"name":"范围","range":"(0,001 – 1000) mg/kg"},{"name":"䓛","range":"(0,001 – 1000) mg/kg"},{"name":"苯并(b)荧蒽","range":"(0,001 – 1000) mg/kg"},{"name":"苯并(k)荧蒽","range":"(0,001 – 1000) mg/kg"},{"name":"苯并(a)芘","range":"(0,001 – 1000) mg/kg"},{"name":"茚并","range":"(1,2,3,-cd)piren"},{"name":"(0,001 – 1000) mg/kg"},{"name":"二苯并(a,h)蒽","range":"(0,001 – 1000) mg/kg"},{"name":"苯并(g,h,i)苝","range":"(0,001 – 1000) mg/kg"}],"search_zh":"多环芳烃（PAHs）含量 气相色谱-质谱法（GC-MS） 萘 苊烯 苊 芴 菲 蒽 荧蒽 芘 苯并(a)蒽 范围 䓛 苯并(b)荧蒽 苯并(k)荧蒽 苯并(a)芘 茚并 二苯并(a,h)蒽 苯并(g,h,i)苝 PB-09 wydanie 6 z dnia 22.02.2024 r.","methodology_zh":"多环芳烃（PAHs）含量","technique_zh":"气相色谱-质谱法（GC-MS）"},{"_id":"6a837952af14b9c0e7b1fcb4","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Grunty, Osady denne, Osady ściekowe, Odpady O) kod: 17 05 05*, 17 05 06","methodology":"Suma wielopierścieniowych węglowodorów aromatycznych (WWA) z obliczeń","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma wielopierścieniowych węglowodorów aromatycznych (WWA) z obliczeń","reference":"I-24 wydanie 3 z dnia 26.02.2024 r.","norm_bases":["I-24 wydanie 3 z dnia 26.02.2024 r."],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":"O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Grunty, Osady denne, Osady ściekowe, Odpady O) kod: 17 05 05*, 17 05 06 Suma wielopierścieniowych węglowodorów aromatycznych (WWA) z obliczeń I-24 wydanie 3 z dnia 26.02.2024 r. Grunty, Osady denne, Osady sciekowe, Odpady O) kod: 17 05 05*, 17 05 06 Suma wielopierscieniowych weglowodorow aromatycznych (WWA) z obliczen I-24 wydanie 3 z dnia 26.02.2024 r.","categories":["water","environment"],"row_index":126,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of polycyclic aromatic hydrocarbons (PAH) calculated","search_en":"Sum of polycyclic aromatic hydrocarbons (PAH) calculated I-24 wydanie 3 z dnia 26.02.2024 r."},{"_id":"6a837952af14b9c0e7b1fcb5","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Grunty, Osady denne, Odpady O) kod: 17 05 05*, 17 05 06","methodology":"Zawartość związków cynoorganicznych:","parameters":[{"name":"Tributylocyna (TBT)","range":"(0,01 – 10) mg/kg"},{"name":"Dibutylocyna (DBT)","range":"(0,001 – 10) mg/kg"},{"name":"Monobutylocyna (MBT)"},{"name":"Zakres","range":"(0,005 – 10) mg/kg"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Zawartość związków cynoorganicznych:\nZakres:\nTributylocyna (TBT) (0,01 – 10) mg/kg\nDibutylocyna (DBT) (0,001 – 10) mg/kg\nMonobutylocyna (MBT)\nZakres (0,005 – 10) mg/kg\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"PN-EN ISO 23161:2019-03","norm_bases":["PN-EN ISO 23161:2019-03"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":"O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Grunty, Osady denne, Odpady O) kod: 17 05 05*, 17 05 06 Zawartość związków cynoorganicznych:\nZakres:\nTributylocyna (TBT) (0,01 – 10) mg/kg\nDibutylocyna (DBT) (0,001 – 10) mg/kg\nMonobutylocyna (MBT)\nZakres (0,005 – 10) mg/kg\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) PN-EN ISO 23161:2019-03 Grunty, Osady denne, Odpady O) kod: 17 05 05*, 17 05 06 Zawartosc zwiazkow cynoorganicznych:\nZakres:\nTributylocyna (TBT) (0,01 – 10) mg/kg\nDibutylocyna (DBT) (0,001 – 10) mg/kg\nMonobutylocyna (MBT)\nZakres (0,005 – 10) mg/kg\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) PN-EN ISO 23161:2019-03","categories":["water","environment"],"row_index":127,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of organotin compounds:","parameters_en":[{"name":"Tributyltin (TBT)","range":"(0,01 – 10) mg/kg"},{"name":"Dibutyltin (DBT)","range":"(0,001 – 10) mg/kg"},{"name":"Monobutyltin (MBT)"},{"name":"Range","range":"(0,005 – 10) mg/kg"}],"search_en":"Content of organotin compounds: Gas chromatography with mass spectrometry detection (GC-MS) Tributyltin (TBT) Dibutyltin (DBT) Monobutyltin (MBT) Range PN-EN ISO 23161:2019-03","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","parameters_zh":[{"name":"Tributylocyna (TBT)","range":"(0,01 – 10) mg/kg"},{"name":"Dibutylocyna (DBT)","range":"(0,001 – 10) mg/kg"},{"name":"Monobutylocyna (MBT)"},{"name":"范围","range":"(0,005 – 10) mg/kg"}],"search_zh":"气相色谱-质谱法（GC-MS） 范围 PN-EN ISO 23161:2019-03","technique_zh":"气相色谱-质谱法（GC-MS）"},{"_id":"6a837952af14b9c0e7b1fcb6","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Ryby","methodology":"Zawartość rtęci","parameters":[{"name":"Zakres","range":"(0,005 - 2,00) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","techniques":["Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji"],"computed":[],"activity":"Zawartość rtęci\nZakres (0,005 - 2,00) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","reference":"PB-41 wydanie 5 z dnia 30.03.2026 r.","norm_bases":["PB-41 wydanie 5 z dnia 30.03.2026 r."],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ryby Zawartość rtęci\nZakres (0,005 - 2,00) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji PB-41 wydanie 5 z dnia 30.03.2026 r. Ryby Zawartosc rteci\nZakres (0,005 - 2,00) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z technika amalgamacji PB-41 wydanie 5 z dnia 30.03.2026 r.","categories":["other"],"row_index":128,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury content","parameters_en":[{"name":"Range","range":"(0,005 - 2,00) mg/kg"}],"search_en":"Fish Mercury content Atomic absorption spectrometry with amalgamation technique Range PB-41 wydanie 5 z dnia 30.03.2026 r.","technique_en":"Atomic absorption spectrometry with amalgamation technique","test_object_en":"Fish","methodology_zh":"汞含量","parameters_zh":[{"name":"范围","range":"(0,005 - 2,00) mg/kg"}],"search_zh":"鱼 汞含量 原子吸收光谱法（汞齐化技术） 范围 PB-41 wydanie 5 z dnia 30.03.2026 r.","technique_zh":"原子吸收光谱法（汞齐化技术）","test_object_zh":"鱼"},{"_id":"6a837952af14b9c0e7b1fcb7","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Ryby","methodology":"Zawartość rtęci","parameters":[{"name":"Zakres","range":"(0,005 – 1,0) mg/kg"}],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"computed":[],"activity":"Zawartość rtęci\nZakres (0,005 – 1,0) mg/kg\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"PB–42 wydanie 7 z dnia 05.06.2025 r.","norm_bases":["PB–42 wydanie 7 z dnia 05.06.2025 r."],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ryby Zawartość rtęci\nZakres (0,005 – 1,0) mg/kg\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) PB–42 wydanie 7 z dnia 05.06.2025 r. Ryby Zawartosc rteci\nZakres (0,005 – 1,0) mg/kg\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) PB–42 wydanie 7 z dnia 05.06.2025 r.","categories":["other"],"row_index":129,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury content","parameters_en":[{"name":"Range","range":"(0,005 – 1,0) mg/kg"}],"search_en":"Fish Mercury content Inductively coupled plasma mass spectrometry (ICP-MS) Range PB–42 wydanie 7 z dnia 05.06.2025 r.","technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","test_object_en":"Fish","methodology_zh":"汞含量","parameters_zh":[{"name":"范围","range":"(0,005 – 1,0) mg/kg"}],"search_zh":"鱼 汞含量 电感耦合等离子体质谱法（ICP-MS） 范围 PB–42 wydanie 7 z dnia 05.06.2025 r.","technique_zh":"电感耦合等离子体质谱法（ICP-MS）","test_object_zh":"鱼"},{"_id":"6a837952af14b9c0e7b1fcb8","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Ryby","methodology":"Zawartość metali","parameters":[{"name":"Pb","range":"(0,005 – 5,0) mg/kg"},{"name":"Cd","range":"(0,0020 – 1,00) mg/kg"},{"name":"As","range":"(0,0050 – 5,00) mg/kg"}],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"computed":[],"activity":"Zawartość metali\nZakres:\nPb (0,005 – 5,0) mg/kg\nCd (0,0020 – 1,00) mg/kg\nAs (0,0050 – 5,00) mg/kg\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"PB–42 wydanie 7 z dnia 05.06.2025 r.","norm_bases":["PB–42 wydanie 7 z dnia 05.06.2025 r."],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ryby Zawartość metali\nZakres:\nPb (0,005 – 5,0) mg/kg\nCd (0,0020 – 1,00) mg/kg\nAs (0,0050 – 5,00) mg/kg\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) PB–42 wydanie 7 z dnia 05.06.2025 r. Ryby Zawartosc metali\nZakres:\nPb (0,005 – 5,0) mg/kg\nCd (0,0020 – 1,00) mg/kg\nAs (0,0050 – 5,00) mg/kg\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) PB–42 wydanie 7 z dnia 05.06.2025 r.","categories":["materials"],"row_index":130,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Metal content","parameters_en":[{"name":"Pb","range":"(0,005 – 5,0) mg/kg"},{"name":"Cd","range":"(0,0020 – 1,00) mg/kg"},{"name":"As","range":"(0,0050 – 5,00) mg/kg"}],"search_en":"Fish Metal content Inductively coupled plasma mass spectrometry (ICP-MS) Pb Cd As PB–42 wydanie 7 z dnia 05.06.2025 r.","technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","test_object_en":"Fish","parameters_zh":[{"name":"Pb","range":"(0,005 – 5,0) mg/kg"},{"name":"Cd","range":"(0,0020 – 1,00) mg/kg"},{"name":"As","range":"(0,0050 – 5,00) mg/kg"}],"search_zh":"鱼 金属含量 电感耦合等离子体质谱法（ICP-MS） Pb Cd As PB–42 wydanie 7 z dnia 05.06.2025 r.","technique_zh":"电感耦合等离子体质谱法（ICP-MS）","methodology_zh":"金属含量","test_object_zh":"鱼"},{"_id":"6a837952af14b9c0e7b1fcb9","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Grunty, Osady denne, Osady ściekowe, Odpady O) kod: 10 01 01, 10 01 02, 10 01 05, 17 05 06, 17 05 05*, 10 01 21, 19 09 05, 10 01 80","methodology":"Zawartość azotu ogólnego","parameters":[{"name":"Zakres","range":"(0,02 – 18,5) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu ogólnego\nZakres (0,02 – 18,5) %\nMetoda miareczkowa","reference":"PN-ISO 11261:2002","norm_bases":["PN-ISO 11261:2002"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":"O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Grunty, Osady denne, Osady ściekowe, Odpady O) kod: 10 01 01, 10 01 02, 10 01 05, 17 05 06, 17 05 05*, 10 01 21, 19 09 05, 10 01 80 Zawartość azotu ogólnego\nZakres (0,02 – 18,5) %\nMetoda miareczkowa PN-ISO 11261:2002 Grunty, Osady denne, Osady sciekowe, Odpady O) kod: 10 01 01, 10 01 02, 10 01 05, 17 05 06, 17 05 05*, 10 01 21, 19 09 05, 10 01 80 Zawartosc azotu ogolnego\nZakres (0,02 – 18,5) %\nMetoda miareczkowa PN-ISO 11261:2002","categories":["water","environment"],"row_index":131,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total nitrogen content","parameters_en":[{"name":"Range","range":"(0,02 – 18,5) %"}],"search_en":"Total nitrogen content Titrimetric method Range PN-ISO 11261:2002","technique_en":"Titrimetric method","parameters_zh":[{"name":"范围","range":"(0,02 – 18,5) %"}],"search_zh":"总氮含量 滴定法 范围 PN-ISO 11261:2002","technique_zh":"滴定法","methodology_zh":"总氮含量"},{"_id":"6a837952af14b9c0e7b1fcba","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Grunty, Osady denne, Osady ściekowe, Odpady O) kod: 10 01 01, 10 01 02, 10 01 05, 17 05 06, 17 05 05*, 10 01 21, 19 09 05, 10 01 80","methodology":"Zawartość rtęci","parameters":[{"name":"Zakres","range":"(0,01 – 50) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","techniques":["Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji"],"computed":[],"activity":"Zawartość rtęci\nZakres (0,01 – 50) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","reference":"PB–21 wydanie 8 z dnia 30.03.2026 r.","norm_bases":["PB–21 wydanie 8 z dnia 30.03.2026 r."],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":"O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Grunty, Osady denne, Osady ściekowe, Odpady O) kod: 10 01 01, 10 01 02, 10 01 05, 17 05 06, 17 05 05*, 10 01 21, 19 09 05, 10 01 80 Zawartość rtęci\nZakres (0,01 – 50) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji PB–21 wydanie 8 z dnia 30.03.2026 r. Grunty, Osady denne, Osady sciekowe, Odpady O) kod: 10 01 01, 10 01 02, 10 01 05, 17 05 06, 17 05 05*, 10 01 21, 19 09 05, 10 01 80 Zawartosc rteci\nZakres (0,01 – 50) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z technika amalgamacji PB–21 wydanie 8 z dnia 30.03.2026 r.","categories":["water","environment"],"row_index":132,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury content","parameters_en":[{"name":"Range","range":"(0,01 – 50) mg/kg"}],"search_en":"Mercury content Atomic absorption spectrometry with amalgamation technique Range PB–21 wydanie 8 z dnia 30.03.2026 r.","technique_en":"Atomic absorption spectrometry with amalgamation technique","methodology_zh":"汞含量","parameters_zh":[{"name":"范围","range":"(0,01 – 50) mg/kg"}],"search_zh":"汞含量 原子吸收光谱法（汞齐化技术） 范围 PB–21 wydanie 8 z dnia 30.03.2026 r.","technique_zh":"原子吸收光谱法（汞齐化技术）"},{"_id":"6a837952af14b9c0e7b1fcbb","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Materiał roślinny","methodology":"Zawartość rtęci","parameters":[{"name":"Zakres","range":"(0,0005 – 1,0) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","techniques":["Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji"],"computed":[],"activity":"Zawartość rtęci\nZakres (0,0005 – 1,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","reference":"PB–21 wydanie 8 z dnia 30.03.2026 r.","norm_bases":["PB–21 wydanie 8 z dnia 30.03.2026 r."],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiał roślinny Zawartość rtęci\nZakres (0,0005 – 1,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji PB–21 wydanie 8 z dnia 30.03.2026 r. Material roslinny Zawartosc rteci\nZakres (0,0005 – 1,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z technika amalgamacji PB–21 wydanie 8 z dnia 30.03.2026 r.","categories":["materials"],"row_index":133,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury content","parameters_en":[{"name":"Range","range":"(0,0005 – 1,0) mg/kg"}],"search_en":"Plant material Mercury content Atomic absorption spectrometry with amalgamation technique Range PB–21 wydanie 8 z dnia 30.03.2026 r.","technique_en":"Atomic absorption spectrometry with amalgamation technique","test_object_en":"Plant material","methodology_zh":"汞含量","parameters_zh":[{"name":"范围","range":"(0,0005 – 1,0) mg/kg"}],"search_zh":"植物材料 汞含量 原子吸收光谱法（汞齐化技术） 范围 PB–21 wydanie 8 z dnia 30.03.2026 r.","technique_zh":"原子吸收光谱法（汞齐化技术）","test_object_zh":"植物材料"},{"_id":"6a837952af14b9c0e7b1fcbc","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Materiał roślinny","methodology":"Zawartość rtęci","parameters":[{"name":"Zakres","range":"(0,005 – 1,0) mg/kg"}],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"computed":[],"activity":"Zawartość rtęci\nZakres (0,005 – 1,0) mg/kg\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"PB–42 wydanie 7 z dnia 05.06.2025 r.","norm_bases":["PB–42 wydanie 7 z dnia 05.06.2025 r."],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiał roślinny Zawartość rtęci\nZakres (0,005 – 1,0) mg/kg\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) PB–42 wydanie 7 z dnia 05.06.2025 r. Material roslinny Zawartosc rteci\nZakres (0,005 – 1,0) mg/kg\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) PB–42 wydanie 7 z dnia 05.06.2025 r.","categories":["materials"],"row_index":134,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury content","parameters_en":[{"name":"Range","range":"(0,005 – 1,0) mg/kg"}],"search_en":"Plant material Mercury content Inductively coupled plasma mass spectrometry (ICP-MS) Range PB–42 wydanie 7 z dnia 05.06.2025 r.","technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","test_object_en":"Plant material","methodology_zh":"汞含量","parameters_zh":[{"name":"范围","range":"(0,005 – 1,0) mg/kg"}],"search_zh":"植物材料 汞含量 电感耦合等离子体质谱法（ICP-MS） 范围 PB–42 wydanie 7 z dnia 05.06.2025 r.","technique_zh":"电感耦合等离子体质谱法（ICP-MS）","test_object_zh":"植物材料"},{"_id":"6a837952af14b9c0e7b1fcbd","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Grunty E, Osady denneE, Osady ściekowe E, Odpady O) E kod : 06 05 02*, 06 05 03, 10 01 01, 10 01 02, 10 01 05, 17 05 05*, 17 05 06, 10 01 21, 19 09 05, 10 01 80","methodology":"Zawartość pierwiastków","parameters":[],"technique":"Metoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość pierwiastków\nMetoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PB-10","norm_bases":["PB-10"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":"Elastyczny zakres elastyczny\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.\nLista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot lub na każde żądanie.\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Grunty E, Osady denneE, Osady ściekowe E, Odpady O) E kod : 06 05 02*, 06 05 03, 10 01 01, 10 01 02, 10 01 05, 17 05 05*, 17 05 06, 10 01 21, 19 09 05, 10 01 80 Zawartość pierwiastków\nMetoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PB-10 Grunty E, Osady denneE, Osady sciekowe E, Odpady O) E kod : 06 05 02*, 06 05 03, 10 01 01, 10 01 02, 10 01 05, 17 05 05*, 17 05 06, 10 01 21, 19 09 05, 10 01 80 Zawartosc pierwiastkow\nMetoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PB-10","categories":["water","environment"],"row_index":135,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element content","regulatory_area_en":"Elastyczny zakres elastyczny\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.\nLista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot lub na każde żądanie.\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","search_en":"Element content Inductively coupled plasma optical emission spectrometry (ICP-OES) Elastyczny zakres elastyczny\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.\nLista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot lub na każde żądanie.\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów PB-10","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","methodology_zh":"元素含量","regulatory_area_zh":"Elastyczny zakres elastyczny\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。\nLista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot lub na każde żądanie.\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","search_zh":"元素含量 电感耦合等离子体发射光谱法（ICP-OES） Elastyczny zakres elastyczny\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。\nLista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot lub na każde żądanie.\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów PB-10","technique_zh":"电感耦合等离子体发射光谱法（ICP-OES）"},{"_id":"6a837952af14b9c0e7b1fcbe","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda E, Woda do spożycia przez ludzi E, Ścieki E","methodology":"Stężenia pierwiastków","parameters":[],"technique":"Metoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenia pierwiastków\nMetoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885","norm_bases":["PN-EN ISO 11885"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":"Elastyczny zakres elastyczny\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.\nLista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot lub na każde żądanie.","flexible":false,"search_text":"Woda E, Woda do spożycia przez ludzi E, Ścieki E Stężenia pierwiastków\nMetoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885 Woda E, Woda do spozycia przez ludzi E, Scieki E Stezenia pierwiastkow\nMetoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885","categories":["water"],"row_index":136,"parse_version":4,"parse_source":"agent-claude-code","regulatory_area_en":"Elastyczny zakres elastyczny\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.\nLista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot lub na każde żądanie.","search_en":"Water E, Water intended for human consumption E, Wastewater E Inductively coupled plasma optical emission spectrometry (ICP-OES) Elastyczny zakres elastyczny\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.\nLista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot lub na każde żądanie. PN-EN ISO 11885","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Water E, Water intended for human consumption E, Wastewater E","regulatory_area_zh":"Elastyczny zakres elastyczny\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。\nLista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot lub na każde żądanie.","search_zh":"水 E、生活饮用水 E、废水 E 电感耦合等离子体发射光谱法（ICP-OES） Elastyczny zakres elastyczny\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。\nLista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot lub na każde żądanie. PN-EN ISO 11885","technique_zh":"电感耦合等离子体发射光谱法（ICP-OES）","test_object_zh":"水 E、生活饮用水 E、废水 E"},{"_id":"6a837952af14b9c0e7b1fcbf","lab_id":"69ad52a3de79e566650fb34e","country":"PL","accr_number":"AB 646","accr_body":"PCA","test_object":"Woda E, Woda do spożycia przez ludzi E, Ścieki E","methodology":"Stężenia pierwiastków","parameters":[],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"computed":[],"activity":"Stężenia pierwiastków\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"PN-EN ISO 17294-2","norm_bases":["PN-EN ISO 17294-2"],"lab_section":"Laboratorium Zakładu Ochrony Środowiska","lab_address":null,"regulatory_area":"Elastyczny zakres elastyczny\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.\nLista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot lub na każde żądanie.","flexible":false,"search_text":"Woda E, Woda do spożycia przez ludzi E, Ścieki E Stężenia pierwiastków\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) PN-EN ISO 17294-2 Woda E, Woda do spozycia przez ludzi E, Scieki E Stezenia pierwiastkow\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) PN-EN ISO 17294-2","categories":["water"],"row_index":137,"parse_version":4,"parse_source":"agent-claude-code","regulatory_area_en":"Elastyczny zakres elastyczny\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.\nLista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot lub na każde żądanie.","search_en":"Water E, Water intended for human consumption E, Wastewater E Inductively coupled plasma mass spectrometry (ICP-MS) Elastyczny zakres elastyczny\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.\nLista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot lub na każde żądanie. PN-EN ISO 17294-2","technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","test_object_en":"Water E, Water intended for human consumption E, Wastewater E","regulatory_area_zh":"Elastyczny zakres elastyczny\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。\nLista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot lub na każde żądanie.","search_zh":"水 E、生活饮用水 E、废水 E 电感耦合等离子体质谱法（ICP-MS） Elastyczny zakres elastyczny\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。\nLista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot lub na każde żądanie. PN-EN ISO 17294-2","technique_zh":"电感耦合等离子体质谱法（ICP-MS）","test_object_zh":"水 E、生活饮用水 E、废水 E"}],"has_pdf":true}