{"lab":{"_id":"69ad52a3de79e566650fb344","accr_number":"AB 635","country":"PL","accr_body":"PCA","address":"W ŁOMŻY, ul. Gen. Władysława Sikorskiego 156, 18-400 Łomża","categories":["water","environment","microbiology","food","pharma"],"city":"Łomża","imported_at":"2026-03-08T10:42:43.265Z","methods_count":96,"name":"POWIATOWA STACJA SANITARNO-EPIDEMIOLOGICZNA","parse_status":"parsed","parse_version":3,"pdf_files":["AB_635.pdf"],"scope_summary":"","search_text":"powiatowa stacja sanitarno-epidemiologiczna w łomży, ul. gen. władysława sikorskiego 156, 18-400 łomża other water pharma electronics microbiology food environment metrology materials construction automotive","status":"active","updated_at":"2026-03-08T14:51:32.593Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-17T21:06:59.302Z","email_confidence":"high","email_mx":true,"email_source":"https://www.gov.pl/web/psse-lomza/dane-kontaktowe","fields_of_testing":[{"codes":"C/28/P, C/29/P","pl":"Badania chemiczne i pobieranie próbek wody, wody do spożycia przez ludzi","en":"Chemical tests and sampling of water, drinking water"},{"codes":"C/33/P","pl":"Badania chemiczne i pobieranie próbek – środowisko pracy (czynniki szkodliwe - powietrze)","en":"Chemical tests and sampling - working environment (harmful factors - air)"},{"codes":"G/33","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki szkodliwe i uciążliwe – hałas, drgania, oświetlenie)","en":"Tests concerning environmental engineering (environmental and climatic) – working environment (harmful and nuisance factors – noise, vibration, lighting)"},{"codes":"K/28/P, K/29/P","pl":"Badania mikrobiologiczne i pobieranie próbek wody, wody do spożycia przez ludzi","en":"Microbiological tests and sampling water, drinking water"},{"codes":"K/3, K/22","pl":"Badania mikrobiologiczne obiektów i materiałów biologicznych przeznaczonych do badań, żywności","en":"Microbiological tests of biological items and materials for testing, food"},{"codes":"N/28/P, N/29/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, wody do spożycia przez ludzi","en":"Tests of physical properties and sampling of water, drinking water"},{"codes":"N/33/P","pl":"Badania właściwości fizycznych i pobieranie próbek – środowisko pracy (czynniki szkodliwe - powietrze)","en":"Tests of physical properties and sampling - working environment (harmful factors - air)"},{"codes":"N/22","pl":"Badania właściwości fizycznych żywności","en":"Tests of physical properties of food"},{"codes":"Q/28/P, Q/29/P","pl":"Badania sensoryczne i pobieranie próbek wody, wody do spożycia przez ludzi","en":"Sensory tests and sampling of water, drinking water"}],"issue":{"no":"28","date":"04.05.2026"},"parse_date":"2026-08-17T21:06:59.302Z","parse_source":"agent-claude-code","map_coord":[53.173906,22.061033],"map_geo":"nominatim-street","lab_locations":[{"name":"Oddział Laboratoryjny; Sekcja Badań Fizykochemicznych","address":"ul. Dworna 21, 18-400 Łomża","city":"Łomża","postal":"18-400"},{"name":"Oddział Laboratoryjny; Sekcja Badań Mikrobiologicznych","address":"ul. Dworna 21, 18-400 Łomża","city":"Łomża","postal":"18-400"},{"name":"Medyczne Laboratorium Diagnostyczne; Sekcja Diagnostyki Medycznej","address":"ul. Dworna 21, 18-400 Łomża","city":"Łomża","postal":"18-400"}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/36e7171dce0be7507d91f8f4f0a2d770/AB%20635.pdf","has_en":true,"category_counts":{"water":55,"environment":23,"microbiology":17,"food":13,"pharma":10,"construction":2,"other":1,"materials":1},"category_scores":{"water":24.8,"environment":4.34,"microbiology":2.37,"food":1.39,"pharma":0.82,"construction":0.03,"other":0.01,"materials":0.01},"has_zh":true},"methods":[{"_id":"6a8377f3af14b9c0e7b1fb0c","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(150 – 3000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (150 – 3000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda Przewodność elektryczna właściwa\nZakres (150 – 3000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda do spozycia przez ludzi, woda Przewodnosc elektryczna wlasciwa\nZakres (150 – 3000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(150 – 3000) μS/cm"}],"search_en":"Water intended for human consumption, water Electrical conductivity Conductometric method Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water intended for human consumption, water","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(150 – 3000) μS/cm"}],"search_zh":"生活饮用水、水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"生活饮用水、水"},{"_id":"6a8377f3af14b9c0e7b1fb0d","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda do spozycia przez ludzi, woda pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"search_en":"Water intended for human consumption, water pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water intended for human consumption, water","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"生活饮用水、水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"生活饮用水、水"},{"_id":"6a8377f3af14b9c0e7b1fb0e","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,20 – 10) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,20 – 10) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09 z wyłączeniem p. 5.4","norm_bases":["PN-EN ISO 7027-1:2016-09 z wyłączeniem p. 5.4"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda Mętność\nZakres (0,20 – 10) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 z wyłączeniem p. 5.4 Woda do spozycia przez ludzi, woda Metnosc\nZakres (0,20 – 10) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 z wylaczeniem p. 5.4","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,20 – 10) NTU"}],"search_en":"Water intended for human consumption, water Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09 z wyłączeniem p. 5.4","technique_en":"Nephelometric method","test_object_en":"Water intended for human consumption, water","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,20 – 10) NTU"}],"search_zh":"生活饮用水、水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09 z wyłączeniem p. 5.4","technique_zh":"浊度法（散射法）","test_object_zh":"生活饮用水、水"},{"_id":"6a8377f3af14b9c0e7b1fb0f","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(5 – 40) mg/l Pt"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Barwa\nZakres (5 – 40) mg/l Pt\nMetoda wizualna","reference":"PN-EN ISO 7887:2012 metoda D","norm_bases":["PN-EN ISO 7887:2012 metoda D"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda Barwa\nZakres (5 – 40) mg/l Pt\nMetoda wizualna PN-EN ISO 7887:2012 metoda D Woda do spozycia przez ludzi, woda Barwa\nZakres (5 – 40) mg/l Pt\nMetoda wizualna PN-EN ISO 7887:2012 metoda D","categories":["water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"(5 – 40) mg/l Pt"}],"search_en":"Water intended for human consumption, water Colour Visual method Range PN-EN ISO 7887:2012 metoda D","technique_en":"Visual method","test_object_en":"Water intended for human consumption, water","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(5 – 40) mg/l Pt"}],"search_zh":"生活饮用水、水 色度 目视法 范围 PN-EN ISO 7887:2012 metoda D","technique_zh":"目视法","test_object_zh":"生活饮用水、水"},{"_id":"6a8377f3af14b9c0e7b1fb10","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(5 – 70) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Barwa\nZakres (5 – 70) mg/l Pt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012 metoda C","norm_bases":["PN-EN ISO 7887:2012 metoda C"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda Barwa\nZakres (5 – 70) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 metoda C Woda do spozycia przez ludzi, woda Barwa\nZakres (5 – 70) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 metoda C","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"(5 – 70) mg/l Pt"}],"search_en":"Water intended for human consumption, water Colour Spectrophotometric method Range PN-EN ISO 7887:2012 metoda C","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption, water","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(5 – 70) mg/l Pt"}],"search_zh":"生活饮用水、水 色度 分光光度法 范围 PN-EN ISO 7887:2012 metoda C","technique_zh":"分光光度法","test_object_zh":"生活饮用水、水"},{"_id":"6a8377f3af14b9c0e7b1fb11","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda","methodology":"Stężenie jonu amonowego","parameters":[{"name":"Zakres","range":"(0,13 – 2,60) mg/l NH4 +"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie jonu amonowego\nZakres (0,13 – 2,60) mg/l NH4 +\nMetoda spektrofotometryczna","reference":"PN-C-04576-4:1994","norm_bases":["PN-C-04576-4:1994"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda Stężenie jonu amonowego\nZakres (0,13 – 2,60) mg/l NH4 +\nMetoda spektrofotometryczna PN-C-04576-4:1994 Woda do spozycia przez ludzi, woda Stezenie jonu amonowego\nZakres (0,13 – 2,60) mg/l NH4 +\nMetoda spektrofotometryczna PN-C-04576-4:1994","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium ion concentration","parameters_en":[{"name":"Range","range":"(0,13 – 2,60) mg/l NH4 +"}],"search_en":"Water intended for human consumption, water Ammonium ion concentration Spectrophotometric method Range PN-C-04576-4:1994","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption, water","methodology_zh":"铵离子浓度","parameters_zh":[{"name":"范围","range":"(0,13 – 2,60) mg/l NH4 +"}],"search_zh":"生活饮用水、水 铵离子浓度 分光光度法 范围 PN-C-04576-4:1994","technique_zh":"分光光度法","test_object_zh":"生活饮用水、水"},{"_id":"6a8377f3af14b9c0e7b1fb12","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda","methodology":"Stężenie azotanów","parameters":[{"name":"Zakres","range":"(0,90 – 221) mg/l NO3-"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotanów\nZakres (0,90 – 221) mg/l NO3-\nMetoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda Stężenie azotanów\nZakres (0,90 – 221) mg/l NO3-\nMetoda spektrofotometryczna PN-82/C-04576/08 Woda do spozycia przez ludzi, woda Stezenie azotanow\nZakres (0,90 – 221) mg/l NO3-\nMetoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate concentration","parameters_en":[{"name":"Range","range":"(0,90 – 221) mg/l NO3-"}],"search_en":"Water intended for human consumption, water Nitrate concentration Spectrophotometric method Range PN-82/C-04576/08","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption, water","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,90 – 221) mg/l NO3-"}],"search_zh":"生活饮用水、水 硝酸盐浓度 分光光度法 范围 PN-82/C-04576/08","technique_zh":"分光光度法","test_object_zh":"生活饮用水、水"},{"_id":"6a8377f3af14b9c0e7b1fb13","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda","methodology":"Stężenie azotynów","parameters":[{"name":"Zakres","range":"(0,026 – 0,21) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotynów\nZakres (0,026 – 0,21) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda Stężenie azotynów\nZakres (0,026 – 0,21) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda do spozycia przez ludzi, woda Stezenie azotynow\nZakres (0,026 – 0,21) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite concentration","parameters_en":[{"name":"Range","range":"(0,026 – 0,21) mg/l"}],"search_en":"Water intended for human consumption, water Nitrite concentration Spectrophotometric method Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption, water","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,026 – 0,21) mg/l"}],"search_zh":"生活饮用水、水 亚硝酸盐浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"生活饮用水、水"},{"_id":"6a8377f3af14b9c0e7b1fb14","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda","methodology":"Stężenie żelaza","parameters":[{"name":"Zakres","range":"(0,050 – 5,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza\nZakres (0,050 – 5,00) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001 z wyłączeniem p.7.2 i p.7.3","norm_bases":["PN-ISO 6332:2001 z wyłączeniem p.7.2 i p.7.3"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda Stężenie żelaza\nZakres (0,050 – 5,00) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001 z wyłączeniem p.7.2 i p.7.3 Woda do spozycia przez ludzi, woda Stezenie zelaza\nZakres (0,050 – 5,00) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001 z wylaczeniem p.7.2 i p.7.3","categories":["water"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Iron concentration","parameters_en":[{"name":"Range","range":"(0,050 – 5,00) mg/l"}],"search_en":"Water intended for human consumption, water Iron concentration Spectrophotometric method Range PN-ISO 6332:2001 z wyłączeniem p.7.2 i p.7.3","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption, water","methodology_zh":"铁浓度","parameters_zh":[{"name":"范围","range":"(0,050 – 5,00) mg/l"}],"search_zh":"生活饮用水、水 铁浓度 分光光度法 范围 PN-ISO 6332:2001 z wyłączeniem p.7.2 i p.7.3","technique_zh":"分光光度法","test_object_zh":"生活饮用水、水"},{"_id":"6a8377f3af14b9c0e7b1fb15","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5 – 150) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5 – 150) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda Stężenie chlorków\nZakres (5 – 150) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda do spozycia przez ludzi, woda Stezenie chlorkow\nZakres (5 – 150) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5 – 150) mg/l"}],"search_en":"Water intended for human consumption, water Chloride concentration Titrimetric method Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Water intended for human consumption, water","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5 – 150) mg/l"}],"search_zh":"生活饮用水、水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"生活饮用水、水"},{"_id":"6a8377f3af14b9c0e7b1fb16","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna).","parameters":[{"name":"Zakres","range":"(50 – 500) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna).\nZakres (50 – 500) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda Sumaryczna zawartość wapnia i magnezu (twardość ogólna).\nZakres (50 – 500) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999 Woda do spozycia przez ludzi, woda Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna).\nZakres (50 – 500) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total calcium and magnesium content (total hardness).","parameters_en":[{"name":"Range","range":"(50 – 500) mg/l CaCO3"}],"search_en":"Water intended for human consumption, water Total calcium and magnesium content (total hardness). Titrimetric method Range PN-ISO 6059:1999","technique_en":"Titrimetric method","test_object_en":"Water intended for human consumption, water","parameters_zh":[{"name":"范围","range":"(50 – 500) mg/l CaCO3"}],"search_zh":"生活饮用水、水 滴定法 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"生活饮用水、水"},{"_id":"6a8377f3af14b9c0e7b1fb17","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(2,5 – 250) mg/l"}],"technique":"Metoda turbidymetryczna","techniques":["Metoda turbidymetryczna"],"computed":[],"activity":"Stężenie siarczanów\nZakres (2,5 – 250) mg/l\nMetoda turbidymetryczna","reference":"PN-79/C-04566/10","norm_bases":["PN-79/C-04566/10"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda Stężenie siarczanów\nZakres (2,5 – 250) mg/l\nMetoda turbidymetryczna PN-79/C-04566/10 Woda do spozycia przez ludzi, woda Stezenie siarczanow\nZakres (2,5 – 250) mg/l\nMetoda turbidymetryczna PN-79/C-04566/10","categories":["water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Range","range":"(2,5 – 250) mg/l"}],"search_en":"Water intended for human consumption, water Sulfate concentration Turbidimetric method Range PN-79/C-04566/10","technique_en":"Turbidimetric method","test_object_en":"Water intended for human consumption, water","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(2,5 – 250) mg/l"}],"search_zh":"生活饮用水、水 硫酸盐浓度 浊度法 范围 PN-79/C-04566/10","test_object_zh":"生活饮用水、水","technique_zh":"浊度法"},{"_id":"6a8377f3af14b9c0e7b1fb18","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda","methodology":"Indeks nadmanganianowy (utlenialność z KMnO4)","parameters":[{"name":"Zakres","range":"(0,50 – 10) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Indeks nadmanganianowy (utlenialność z KMnO4)\nZakres (0,50 – 10) mg/l O2\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda Indeks nadmanganianowy (utlenialność z KMnO4)\nZakres (0,50 – 10) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda do spozycia przez ludzi, woda Indeks nadmanganianowy (utlenialnosc z KMnO4)\nZakres (0,50 – 10) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Permanganate index (oxidisability with KMnO4)","parameters_en":[{"name":"Range","range":"(0,50 – 10) mg/l O2"}],"search_en":"Water intended for human consumption, water Permanganate index (oxidisability with KMnO4) Titrimetric method Range PN-EN ISO 8467:2001","technique_en":"Titrimetric method","test_object_en":"Water intended for human consumption, water","parameters_zh":[{"name":"范围","range":"(0,50 – 10) mg/l O2"}],"search_zh":"生活饮用水、水 高锰酸盐指数（KMnO4 耗氧量） 滴定法 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"生活饮用水、水","methodology_zh":"高锰酸盐指数（KMnO4 耗氧量）"},{"_id":"6a8377f3af14b9c0e7b1fb19","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda","methodology":"Stężenie fluorków","parameters":[{"name":"Zakres","range":"(0,10 – 20,0) mg/l"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"Stężenie fluorków\nZakres (0,10 – 20,0) mg/l\nMetoda potencjometryczna","reference":"PN-78/C-04588/03","norm_bases":["PN-78/C-04588/03"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda Stężenie fluorków\nZakres (0,10 – 20,0) mg/l\nMetoda potencjometryczna PN-78/C-04588/03 Woda do spozycia przez ludzi, woda Stezenie fluorkow\nZakres (0,10 – 20,0) mg/l\nMetoda potencjometryczna PN-78/C-04588/03","categories":["water"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fluoride concentration","parameters_en":[{"name":"Range","range":"(0,10 – 20,0) mg/l"}],"search_en":"Water intended for human consumption, water Fluoride concentration Potentiometric method Range PN-78/C-04588/03","technique_en":"Potentiometric method","test_object_en":"Water intended for human consumption, water","parameters_zh":[{"name":"范围","range":"(0,10 – 20,0) mg/l"}],"search_zh":"生活饮用水、水 氟化物浓度 电位法 范围 PN-78/C-04588/03","technique_zh":"电位法","test_object_zh":"生活饮用水、水","methodology_zh":"氟化物浓度"},{"_id":"6a8377f3af14b9c0e7b1fb1a","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda","methodology":"Stężenie anionów","parameters":[{"name":"Azotany","range":"(1,0 – 50) mg/l"},{"name":"Azotyny","range":"(0,05 – 2,5) mg/l"},{"name":"Chlorki","range":"(5,0 – 250) mg/l"},{"name":"Fluorki","range":"(0,10 – 5,0) mg/l"},{"name":"Siarczany","range":"(5,0 – 250) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie anionów\nZakres:\nAzotany (1,0 – 50) mg/l\nAzotyny (0,05 – 2,5) mg/l\nChlorki (5,0 – 250) mg/l\nFluorki (0,10 – 5,0) mg/l\nSiarczany (5,0 – 250) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009 +AC:2012","norm_bases":["PN-EN ISO 10304-1:2009 +AC:2012"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda Stężenie anionów\nZakres:\nAzotany (1,0 – 50) mg/l\nAzotyny (0,05 – 2,5) mg/l\nChlorki (5,0 – 250) mg/l\nFluorki (0,10 – 5,0) mg/l\nSiarczany (5,0 – 250) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009 +AC:2012 Woda do spozycia przez ludzi, woda Stezenie anionow\nZakres:\nAzotany (1,0 – 50) mg/l\nAzotyny (0,05 – 2,5) mg/l\nChlorki (5,0 – 250) mg/l\nFluorki (0,10 – 5,0) mg/l\nSiarczany (5,0 – 250) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009 +AC:2012","categories":["water"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Anion concentrations","parameters_en":[{"name":"Nitrates","range":"(1,0 – 50) mg/l"},{"name":"Nitrites","range":"(0,05 – 2,5) mg/l"},{"name":"Chlorides","range":"(5,0 – 250) mg/l"},{"name":"Fluorides","range":"(0,10 – 5,0) mg/l"},{"name":"Sulfates","range":"(5,0 – 250) mg/l"}],"search_en":"Water intended for human consumption, water Anion concentrations Ion chromatography with conductometric detection (IC-CD) Nitrates Nitrites Chlorides Fluorides Sulfates PN-EN ISO 10304-1:2009 +AC:2012","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water intended for human consumption, water","methodology_zh":"阴离子浓度","parameters_zh":[{"name":"硝酸盐","range":"(1,0 – 50) mg/l"},{"name":"亚硝酸盐","range":"(0,05 – 2,5) mg/l"},{"name":"氯化物","range":"(5,0 – 250) mg/l"},{"name":"氟化物","range":"(0,10 – 5,0) mg/l"},{"name":"硫酸盐","range":"(5,0 – 250) mg/l"}],"search_zh":"生活饮用水、水 阴离子浓度 离子色谱-电导检测法（IC-CD） 硝酸盐 亚硝酸盐 氯化物 氟化物 硫酸盐 PN-EN ISO 10304-1:2009 +AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"生活饮用水、水"},{"_id":"6a8377f3af14b9c0e7b1fb1b","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda","methodology":"Stężenie anionów","parameters":[{"name":"Chlorany","range":"(0,07- 0,70) mg/l"},{"name":"Chloryny","range":"(0,07- 0,70) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie anionów\nZakres:\nChlorany (0,07- 0,70) mg/l\nChloryny (0,07- 0,70) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-4:2022-08","norm_bases":["PN-EN ISO 10304-4:2022-08"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda Stężenie anionów\nZakres:\nChlorany (0,07- 0,70) mg/l\nChloryny (0,07- 0,70) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-4:2022-08 Woda do spozycia przez ludzi, woda Stezenie anionow\nZakres:\nChlorany (0,07- 0,70) mg/l\nChloryny (0,07- 0,70) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-4:2022-08","categories":["water"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Anion concentrations","parameters_en":[{"name":"Chlorates","range":"(0,07- 0,70) mg/l"},{"name":"Chlorites","range":"(0,07- 0,70) mg/l"}],"search_en":"Water intended for human consumption, water Anion concentrations Ion chromatography with conductometric detection (IC-CD) Chlorates Chlorites PN-EN ISO 10304-4:2022-08","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water intended for human consumption, water","methodology_zh":"阴离子浓度","search_zh":"生活饮用水、水 阴离子浓度 离子色谱-电导检测法（IC-CD） 氯酸盐 亚氯酸盐 PN-EN ISO 10304-4:2022-08","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"生活饮用水、水","parameters_zh":[{"name":"氯酸盐","range":"(0,07- 0,70) mg/l"},{"name":"亚氯酸盐","range":"(0,07- 0,70) mg/l"}]},{"_id":"6a8377f3af14b9c0e7b1fb1c","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda","methodology":"Σ chloranów i chlorynów (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Σ chloranów i chlorynów (z obliczeń)","reference":"PN-EN ISO 10304-4:2022-08","norm_bases":["PN-EN ISO 10304-4:2022-08"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda Σ chloranów i chlorynów (z obliczeń) PN-EN ISO 10304-4:2022-08 Woda do spozycia przez ludzi, woda Σ chloranow i chlorynow (z obliczen) PN-EN ISO 10304-4:2022-08","categories":["water"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Water intended for human consumption, water PN-EN ISO 10304-4:2022-08","test_object_en":"Water intended for human consumption, water","search_zh":"生活饮用水、水 PN-EN ISO 10304-4:2022-08","test_object_zh":"生活饮用水、水"},{"_id":"6a8377f3af14b9c0e7b1fb1d","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda","methodology":"Stężenie kadmu","parameters":[{"name":"Zakres","range":"(1,0 – 10) μg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie kadmu\nZakres (1,0 – 10) μg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 8288:2002 metoda B","norm_bases":["PN-ISO 8288:2002 metoda B"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda Stężenie kadmu\nZakres (1,0 – 10) μg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 metoda B Woda do spozycia przez ludzi, woda Stezenie kadmu\nZakres (1,0 – 10) μg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 metoda B","categories":["water"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Cadmium concentration","parameters_en":[{"name":"Range","range":"(1,0 – 10) μg/l"}],"search_en":"Water intended for human consumption, water Cadmium concentration Flame atomic absorption spectrometry (FAAS) Range PN-ISO 8288:2002 metoda B","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Water intended for human consumption, water","parameters_zh":[{"name":"范围","range":"(1,0 – 10) μg/l"}],"search_zh":"生活饮用水、水 镉浓度 火焰原子吸收光谱法（FAAS） 范围 PN-ISO 8288:2002 metoda B","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"生活饮用水、水","methodology_zh":"镉浓度"},{"_id":"6a8377f3af14b9c0e7b1fb1e","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda","methodology":"Stężenie miedzi","parameters":[{"name":"Zakres","range":"(0,05 – 1,0) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie miedzi\nZakres (0,05 – 1,0) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 8288:2002 metoda A","norm_bases":["PN-ISO 8288:2002 metoda A"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda Stężenie miedzi\nZakres (0,05 – 1,0) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 metoda A Woda do spozycia przez ludzi, woda Stezenie miedzi\nZakres (0,05 – 1,0) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 metoda A","categories":["water"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Copper concentration","parameters_en":[{"name":"Range","range":"(0,05 – 1,0) mg/l"}],"search_en":"Water intended for human consumption, water Copper concentration Flame atomic absorption spectrometry (FAAS) Range PN-ISO 8288:2002 metoda A","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Water intended for human consumption, water","parameters_zh":[{"name":"范围","range":"(0,05 – 1,0) mg/l"}],"search_zh":"生活饮用水、水 铜浓度 火焰原子吸收光谱法（FAAS） 范围 PN-ISO 8288:2002 metoda A","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"生活饮用水、水","methodology_zh":"铜浓度"},{"_id":"6a8377f3af14b9c0e7b1fb1f","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda","methodology":"Stężenie manganu","parameters":[{"name":"Zakres","range":"(20,0 – 1000) μg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie manganu\nZakres (20,0 – 1000) μg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-92/C-04570/01","norm_bases":["PN-92/C-04570/01"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda Stężenie manganu\nZakres (20,0 – 1000) μg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-92/C-04570/01 Woda do spozycia przez ludzi, woda Stezenie manganu\nZakres (20,0 – 1000) μg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-92/C-04570/01","categories":["water"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Manganese concentration","parameters_en":[{"name":"Range","range":"(20,0 – 1000) μg/l"}],"search_en":"Water intended for human consumption, water Manganese concentration Flame atomic absorption spectrometry (FAAS) Range PN-92/C-04570/01","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Water intended for human consumption, water","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(20,0 – 1000) μg/l"}],"search_zh":"生活饮用水、水 锰浓度 火焰原子吸收光谱法（FAAS） 范围 PN-92/C-04570/01","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"生活饮用水、水"},{"_id":"6a8377f3af14b9c0e7b1fb20","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda","methodology":"Stężenie sodu","parameters":[{"name":"Zakres","range":"(1,0 – 250) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie sodu\nZakres (1,0 – 250) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 9964-1:1994+Ap1:2009","norm_bases":["PN-ISO 9964-1:1994+Ap1:2009"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda Stężenie sodu\nZakres (1,0 – 250) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 9964-1:1994+Ap1:2009 Woda do spozycia przez ludzi, woda Stezenie sodu\nZakres (1,0 – 250) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 9964-1:1994+Ap1:2009","categories":["water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sodium concentration","parameters_en":[{"name":"Range","range":"(1,0 – 250) mg/l"}],"search_en":"Water intended for human consumption, water Sodium concentration Flame atomic absorption spectrometry (FAAS) Range PN-ISO 9964-1:1994+Ap1:2009","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Water intended for human consumption, water","parameters_zh":[{"name":"范围","range":"(1,0 – 250) mg/l"}],"search_zh":"生活饮用水、水 钠浓度 火焰原子吸收光谱法（FAAS） 范围 PN-ISO 9964-1:1994+Ap1:2009","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"生活饮用水、水","methodology_zh":"钠浓度"},{"_id":"6a8377f3af14b9c0e7b1fb21","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda","methodology":"Stężenie magnezu","parameters":[{"name":"Zakres","range":"(0,5 – 125) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie magnezu\nZakres (0,5 – 125) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-EN ISO 7980:2002","norm_bases":["PN-EN ISO 7980:2002"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda Stężenie magnezu\nZakres (0,5 – 125) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN ISO 7980:2002 Woda do spozycia przez ludzi, woda Stezenie magnezu\nZakres (0,5 – 125) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN ISO 7980:2002","categories":["water"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnesium concentration","parameters_en":[{"name":"Range","range":"(0,5 – 125) mg/l"}],"search_en":"Water intended for human consumption, water Magnesium concentration Flame atomic absorption spectrometry (FAAS) Range PN-EN ISO 7980:2002","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Water intended for human consumption, water","parameters_zh":[{"name":"范围","range":"(0,5 – 125) mg/l"}],"search_zh":"生活饮用水、水 镁浓度 火焰原子吸收光谱法（FAAS） 范围 PN-EN ISO 7980:2002","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"生活饮用水、水","methodology_zh":"镁浓度"},{"_id":"6a8377f3af14b9c0e7b1fb22","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda","methodology":"Stężenie chloru wolnego","parameters":[{"name":"Zakres","range":"(0,04 – 4,5) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chloru wolnego\nZakres (0,04 – 4,5) mg/l\nMetoda spektrofotometryczna","reference":"Aplikacja kolorymetru Merck na podstawie testu Merck nr 1.00599","norm_bases":["Aplikacja kolorymetru Merck na podstawie testu Merck nr 1.00599"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda Stężenie chloru wolnego\nZakres (0,04 – 4,5) mg/l\nMetoda spektrofotometryczna Aplikacja kolorymetru Merck na podstawie testu Merck nr 1.00599 Woda do spozycia przez ludzi, woda Stezenie chloru wolnego\nZakres (0,04 – 4,5) mg/l\nMetoda spektrofotometryczna Aplikacja kolorymetru Merck na podstawie testu Merck nr 1.00599","categories":["water"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free chlorine concentration","parameters_en":[{"name":"Range","range":"(0,04 – 4,5) mg/l"}],"search_en":"Water intended for human consumption, water Free chlorine concentration Spectrophotometric method Range Aplikacja kolorymetru Merck na podstawie testu Merck nr 1.00599","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption, water","methodology_zh":"游离氯浓度","parameters_zh":[{"name":"范围","range":"(0,04 – 4,5) mg/l"}],"search_zh":"生活饮用水、水 游离氯浓度 分光光度法 范围 Aplikacja kolorymetru Merck na podstawie testu Merck nr 1.00599","technique_zh":"分光光度法","test_object_zh":"生活饮用水、水"},{"_id":"6a8377f3af14b9c0e7b1fb23","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda","methodology":"Stężenie chloru ogólnego","parameters":[{"name":"Zakres","range":"(0,04 – 4,5) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chloru ogólnego\nZakres (0,04 – 4,5) mg/l\nMetoda spektrofotometryczna","reference":"Aplikacja kolorymetru Merck na podstawie testu Merck nr 1.00599","norm_bases":["Aplikacja kolorymetru Merck na podstawie testu Merck nr 1.00599"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda Stężenie chloru ogólnego\nZakres (0,04 – 4,5) mg/l\nMetoda spektrofotometryczna Aplikacja kolorymetru Merck na podstawie testu Merck nr 1.00599 Woda do spozycia przez ludzi, woda Stezenie chloru ogolnego\nZakres (0,04 – 4,5) mg/l\nMetoda spektrofotometryczna Aplikacja kolorymetru Merck na podstawie testu Merck nr 1.00599","categories":["water"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total chlorine concentration","parameters_en":[{"name":"Range","range":"(0,04 – 4,5) mg/l"}],"search_en":"Water intended for human consumption, water Total chlorine concentration Spectrophotometric method Range Aplikacja kolorymetru Merck na podstawie testu Merck nr 1.00599","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption, water","parameters_zh":[{"name":"范围","range":"(0,04 – 4,5) mg/l"}],"search_zh":"生活饮用水、水 总氯浓度 分光光度法 范围 Aplikacja kolorymetru Merck na podstawie testu Merck nr 1.00599","technique_zh":"分光光度法","test_object_zh":"生活饮用水、水","methodology_zh":"总氯浓度"},{"_id":"6a8377f3af14b9c0e7b1fb24","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda","methodology":"Stężenie chloru związanego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie chloru związanego (z obliczeń)","reference":"Aplikacja kolorymetru Merck na podstawie testu Merck nr 1.00599","norm_bases":["Aplikacja kolorymetru Merck na podstawie testu Merck nr 1.00599"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda Stężenie chloru związanego (z obliczeń) Aplikacja kolorymetru Merck na podstawie testu Merck nr 1.00599 Woda do spozycia przez ludzi, woda Stezenie chloru zwiazanego (z obliczen) Aplikacja kolorymetru Merck na podstawie testu Merck nr 1.00599","categories":["water"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Combined chlorine concentration (calculated)","search_en":"Water intended for human consumption, water Combined chlorine concentration (calculated) Aplikacja kolorymetru Merck na podstawie testu Merck nr 1.00599","test_object_en":"Water intended for human consumption, water","search_zh":"生活饮用水、水 化合氯浓度（计算值） Aplikacja kolorymetru Merck na podstawie testu Merck nr 1.00599","test_object_zh":"生活饮用水、水","methodology_zh":"化合氯浓度（计算值）"},{"_id":"6a8377f3af14b9c0e7b1fb25","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda","methodology":"Stężenie ozonu","parameters":[{"name":"Zakres","range":"(0,03 – 2,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie ozonu\nZakres (0,03 – 2,0) mg/l\nMetoda spektrofotometryczna","reference":"Aplikacja kolorymetru Merck na podstawie testu Merck nr 1.00607","norm_bases":["Aplikacja kolorymetru Merck na podstawie testu Merck nr 1.00607"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda Stężenie ozonu\nZakres (0,03 – 2,0) mg/l\nMetoda spektrofotometryczna Aplikacja kolorymetru Merck na podstawie testu Merck nr 1.00607 Woda do spozycia przez ludzi, woda Stezenie ozonu\nZakres (0,03 – 2,0) mg/l\nMetoda spektrofotometryczna Aplikacja kolorymetru Merck na podstawie testu Merck nr 1.00607","categories":["water"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ozone concentration","parameters_en":[{"name":"Range","range":"(0,03 – 2,0) mg/l"}],"search_en":"Water intended for human consumption, water Ozone concentration Spectrophotometric method Range Aplikacja kolorymetru Merck na podstawie testu Merck nr 1.00607","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption, water","parameters_zh":[{"name":"范围","range":"(0,03 – 2,0) mg/l"}],"search_zh":"生活饮用水、水 臭氧浓度 分光光度法 范围 Aplikacja kolorymetru Merck na podstawie testu Merck nr 1.00607","technique_zh":"分光光度法","test_object_zh":"生活饮用水、水","methodology_zh":"臭氧浓度"},{"_id":"6a8377f3af14b9c0e7b1fb26","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda","methodology":"Liczba progowa zapachu TON","parameters":[{"name":"Zakres","range":"1"}],"technique":"Metoda uproszczona, parzysta, wybór niewymuszony","techniques":["Metoda uproszczona, parzysta, wybór niewymuszony"],"computed":[],"activity":"Liczba progowa zapachu TON\nZakres 1\nMetoda uproszczona, parzysta, wybór niewymuszony","reference":"PN-EN 1622:2006","norm_bases":["PN-EN 1622:2006"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda Liczba progowa zapachu TON\nZakres 1\nMetoda uproszczona, parzysta, wybór niewymuszony PN-EN 1622:2006 Woda do spozycia przez ludzi, woda Liczba progowa zapachu TON\nZakres 1\nMetoda uproszczona, parzysta, wybor niewymuszony PN-EN 1622:2006","categories":["water"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Odour threshold number TON","parameters_en":[{"name":"Range","range":"1"}],"search_en":"Water intended for human consumption, water Odour threshold number TON Simplified method, paired, non-forced choice Range PN-EN 1622:2006","technique_en":"Simplified method, paired, non-forced choice","test_object_en":"Water intended for human consumption, water","parameters_zh":[{"name":"范围","range":"1"}],"search_zh":"生活饮用水、水 嗅阈值 TON 简化法，成对，非强制选择 范围 PN-EN 1622:2006","test_object_zh":"生活饮用水、水","technique_zh":"简化法，成对，非强制选择","methodology_zh":"嗅阈值 TON"},{"_id":"6a8377f3af14b9c0e7b1fb27","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda","methodology":"Liczba progowa zapachu TON","parameters":[{"name":"Zakres","range":"1 – 4"}],"technique":"Metoda pełna, parzysta, wybór niewymuszony","techniques":["Metoda pełna, parzysta, wybór niewymuszony"],"computed":[],"activity":"Liczba progowa zapachu TON\nZakres 1 – 4\nMetoda pełna, parzysta, wybór niewymuszony","reference":"PN-EN 1622:2006","norm_bases":["PN-EN 1622:2006"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda Liczba progowa zapachu TON\nZakres 1 – 4\nMetoda pełna, parzysta, wybór niewymuszony PN-EN 1622:2006 Woda do spozycia przez ludzi, woda Liczba progowa zapachu TON\nZakres 1 – 4\nMetoda pelna, parzysta, wybor niewymuszony PN-EN 1622:2006","categories":["water"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Odour threshold number TON","parameters_en":[{"name":"Range","range":"1 – 4"}],"search_en":"Water intended for human consumption, water Odour threshold number TON Full paired method, non-forced choice Range PN-EN 1622:2006","technique_en":"Full paired method, non-forced choice","test_object_en":"Water intended for human consumption, water","parameters_zh":[{"name":"范围","range":"1 – 4"}],"search_zh":"生活饮用水、水 嗅阈值 TON 完全法、成对法、非强制选择 范围 PN-EN 1622:2006","test_object_zh":"生活饮用水、水","methodology_zh":"嗅阈值 TON","technique_zh":"完全法、成对法、非强制选择"},{"_id":"6a8377f3af14b9c0e7b1fb28","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda","methodology":"Liczba progowa smaku TFN","parameters":[{"name":"Zakres","range":"1"}],"technique":"Metoda uproszczona, parzysta, wybór niewymuszony","techniques":["Metoda uproszczona, parzysta, wybór niewymuszony"],"computed":[],"activity":"Liczba progowa smaku TFN\nZakres 1\nMetoda uproszczona, parzysta, wybór niewymuszony","reference":"PN-EN 1622:2006","norm_bases":["PN-EN 1622:2006"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda Liczba progowa smaku TFN\nZakres 1\nMetoda uproszczona, parzysta, wybór niewymuszony PN-EN 1622:2006 Woda do spozycia przez ludzi, woda Liczba progowa smaku TFN\nZakres 1\nMetoda uproszczona, parzysta, wybor niewymuszony PN-EN 1622:2006","categories":["water"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Taste threshold number TFN","parameters_en":[{"name":"Range","range":"1"}],"search_en":"Water intended for human consumption, water Taste threshold number TFN Simplified method, paired, non-forced choice Range PN-EN 1622:2006","technique_en":"Simplified method, paired, non-forced choice","test_object_en":"Water intended for human consumption, water","parameters_zh":[{"name":"范围","range":"1"}],"search_zh":"生活饮用水、水 味阈值 TFN 简化法，成对，非强制选择 范围 PN-EN 1622:2006","test_object_zh":"生活饮用水、水","technique_zh":"简化法，成对，非强制选择","methodology_zh":"味阈值 TFN"},{"_id":"6a8377f3af14b9c0e7b1fb29","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda","methodology":"Liczba progowa smaku TFN","parameters":[{"name":"Zakres","range":"1 – 4"}],"technique":"Metoda pełna, parzysta, wybór niewymuszony","techniques":["Metoda pełna, parzysta, wybór niewymuszony"],"computed":[],"activity":"Liczba progowa smaku TFN\nZakres 1 – 4\nMetoda pełna, parzysta, wybór niewymuszony","reference":"PN-EN 1622:2006","norm_bases":["PN-EN 1622:2006"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda Liczba progowa smaku TFN\nZakres 1 – 4\nMetoda pełna, parzysta, wybór niewymuszony PN-EN 1622:2006 Woda do spozycia przez ludzi, woda Liczba progowa smaku TFN\nZakres 1 – 4\nMetoda pelna, parzysta, wybor niewymuszony PN-EN 1622:2006","categories":["water"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Taste threshold number TFN","parameters_en":[{"name":"Range","range":"1 – 4"}],"search_en":"Water intended for human consumption, water Taste threshold number TFN Full paired method, non-forced choice Range PN-EN 1622:2006","technique_en":"Full paired method, non-forced choice","test_object_en":"Water intended for human consumption, water","parameters_zh":[{"name":"范围","range":"1 – 4"}],"search_zh":"生活饮用水、水 味阈值 TFN 完全法、成对法、非强制选择 范围 PN-EN 1622:2006","test_object_zh":"生活饮用水、水","methodology_zh":"味阈值 TFN","technique_zh":"完全法、成对法、非强制选择"},{"_id":"6a8377f3af14b9c0e7b1fb2a","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda na plywalniach pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"search_en":"Swimming pool water pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Swimming pool water","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"游泳池水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"游泳池水"},{"_id":"6a8377f3af14b9c0e7b1fb2b","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,20 – 10) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,20 – 10) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09 z wyłączeniem p.5.4","norm_bases":["PN-EN ISO 7027-1:2016-09 z wyłączeniem p.5.4"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Mętność\nZakres (0,20 – 10) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 z wyłączeniem p.5.4 Woda na plywalniach Metnosc\nZakres (0,20 – 10) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 z wylaczeniem p.5.4","categories":["water"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,20 – 10) NTU"}],"search_en":"Swimming pool water Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09 z wyłączeniem p.5.4","technique_en":"Nephelometric method","test_object_en":"Swimming pool water","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,20 – 10) NTU"}],"search_zh":"游泳池水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09 z wyłączeniem p.5.4","technique_zh":"浊度法（散射法）","test_object_zh":"游泳池水"},{"_id":"6a8377f3af14b9c0e7b1fb2c","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Stężenie azotanów","parameters":[{"name":"Zakres","range":"(0,90 – 221) mg/l NO3-"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotanów\nZakres (0,90 – 221) mg/l NO3-\nMetoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Stężenie azotanów\nZakres (0,90 – 221) mg/l NO3-\nMetoda spektrofotometryczna PN-82/C-04576/08 Woda na plywalniach Stezenie azotanow\nZakres (0,90 – 221) mg/l NO3-\nMetoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate concentration","parameters_en":[{"name":"Range","range":"(0,90 – 221) mg/l NO3-"}],"search_en":"Swimming pool water Nitrate concentration Spectrophotometric method Range PN-82/C-04576/08","technique_en":"Spectrophotometric method","test_object_en":"Swimming pool water","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,90 – 221) mg/l NO3-"}],"search_zh":"游泳池水 硝酸盐浓度 分光光度法 范围 PN-82/C-04576/08","technique_zh":"分光光度法","test_object_zh":"游泳池水"},{"_id":"6a8377f3af14b9c0e7b1fb2d","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Stężenie żelaza","parameters":[{"name":"Zakres","range":"(0,050 – 5,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza\nZakres (0,050 – 5,00) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001 z wyłączeniem p.7.2 i p.7.3","norm_bases":["PN-ISO 6332:2001 z wyłączeniem p.7.2 i p.7.3"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Stężenie żelaza\nZakres (0,050 – 5,00) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001 z wyłączeniem p.7.2 i p.7.3 Woda na plywalniach Stezenie zelaza\nZakres (0,050 – 5,00) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001 z wylaczeniem p.7.2 i p.7.3","categories":["water"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Iron concentration","parameters_en":[{"name":"Range","range":"(0,050 – 5,00) mg/l"}],"search_en":"Swimming pool water Iron concentration Spectrophotometric method Range PN-ISO 6332:2001 z wyłączeniem p.7.2 i p.7.3","technique_en":"Spectrophotometric method","test_object_en":"Swimming pool water","methodology_zh":"铁浓度","parameters_zh":[{"name":"范围","range":"(0,050 – 5,00) mg/l"}],"search_zh":"游泳池水 铁浓度 分光光度法 范围 PN-ISO 6332:2001 z wyłączeniem p.7.2 i p.7.3","technique_zh":"分光光度法","test_object_zh":"游泳池水"},{"_id":"6a8377f3af14b9c0e7b1fb2e","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Indeks nadmanganianowy (utlenialność z KmnO4)","parameters":[{"name":"Zakres","range":"(0,50 – 10) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Indeks nadmanganianowy (utlenialność z KmnO4)\nZakres (0,50 – 10) mg/l O2\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Indeks nadmanganianowy (utlenialność z KmnO4)\nZakres (0,50 – 10) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda na plywalniach Indeks nadmanganianowy (utlenialnosc z KmnO4)\nZakres (0,50 – 10) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,50 – 10) mg/l O2"}],"search_en":"Swimming pool water Titrimetric method Range PN-EN ISO 8467:2001","technique_en":"Titrimetric method","test_object_en":"Swimming pool water","parameters_zh":[{"name":"范围","range":"(0,50 – 10) mg/l O2"}],"search_zh":"游泳池水 滴定法 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"游泳池水"},{"_id":"6a8377f3af14b9c0e7b1fb2f","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Stężenie chloru wolnego","parameters":[{"name":"Zakres","range":"(0,04 – 4,5) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chloru wolnego\nZakres (0,04 – 4,5) mg/l\nMetoda spektrofotometryczna","reference":"Aplikacja kolorymetru Merck na podstawie testu Merck nr 1.00599","norm_bases":["Aplikacja kolorymetru Merck na podstawie testu Merck nr 1.00599"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Stężenie chloru wolnego\nZakres (0,04 – 4,5) mg/l\nMetoda spektrofotometryczna Aplikacja kolorymetru Merck na podstawie testu Merck nr 1.00599 Woda na plywalniach Stezenie chloru wolnego\nZakres (0,04 – 4,5) mg/l\nMetoda spektrofotometryczna Aplikacja kolorymetru Merck na podstawie testu Merck nr 1.00599","categories":["water"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free chlorine concentration","parameters_en":[{"name":"Range","range":"(0,04 – 4,5) mg/l"}],"search_en":"Swimming pool water Free chlorine concentration Spectrophotometric method Range Aplikacja kolorymetru Merck na podstawie testu Merck nr 1.00599","technique_en":"Spectrophotometric method","test_object_en":"Swimming pool water","methodology_zh":"游离氯浓度","parameters_zh":[{"name":"范围","range":"(0,04 – 4,5) mg/l"}],"search_zh":"游泳池水 游离氯浓度 分光光度法 范围 Aplikacja kolorymetru Merck na podstawie testu Merck nr 1.00599","technique_zh":"分光光度法","test_object_zh":"游泳池水"},{"_id":"6a8377f3af14b9c0e7b1fb30","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Stężenie chloru ogólnego","parameters":[{"name":"Zakres","range":"(0,04 – 4,5) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chloru ogólnego\nZakres (0,04 – 4,5) mg/l\nMetoda spektrofotometryczna","reference":"Aplikacja kolorymetru Merck na podstawie testu Merck nr 1.00599","norm_bases":["Aplikacja kolorymetru Merck na podstawie testu Merck nr 1.00599"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Stężenie chloru ogólnego\nZakres (0,04 – 4,5) mg/l\nMetoda spektrofotometryczna Aplikacja kolorymetru Merck na podstawie testu Merck nr 1.00599 Woda na plywalniach Stezenie chloru ogolnego\nZakres (0,04 – 4,5) mg/l\nMetoda spektrofotometryczna Aplikacja kolorymetru Merck na podstawie testu Merck nr 1.00599","categories":["water"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total chlorine concentration","parameters_en":[{"name":"Range","range":"(0,04 – 4,5) mg/l"}],"search_en":"Swimming pool water Total chlorine concentration Spectrophotometric method Range Aplikacja kolorymetru Merck na podstawie testu Merck nr 1.00599","technique_en":"Spectrophotometric method","test_object_en":"Swimming pool water","parameters_zh":[{"name":"范围","range":"(0,04 – 4,5) mg/l"}],"search_zh":"游泳池水 总氯浓度 分光光度法 范围 Aplikacja kolorymetru Merck na podstawie testu Merck nr 1.00599","technique_zh":"分光光度法","test_object_zh":"游泳池水","methodology_zh":"总氯浓度"},{"_id":"6a8377f3af14b9c0e7b1fb31","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Stężenie chloru związanego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie chloru związanego (z obliczeń)","reference":"Aplikacja kolorymetru Merck na podstawie testu Merck nr 1.00599","norm_bases":["Aplikacja kolorymetru Merck na podstawie testu Merck nr 1.00599"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Stężenie chloru związanego (z obliczeń) Aplikacja kolorymetru Merck na podstawie testu Merck nr 1.00599 Woda na plywalniach Stezenie chloru zwiazanego (z obliczen) Aplikacja kolorymetru Merck na podstawie testu Merck nr 1.00599","categories":["water"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Combined chlorine concentration (calculated)","search_en":"Swimming pool water Combined chlorine concentration (calculated) Aplikacja kolorymetru Merck na podstawie testu Merck nr 1.00599","test_object_en":"Swimming pool water","search_zh":"游泳池水 化合氯浓度（计算值） Aplikacja kolorymetru Merck na podstawie testu Merck nr 1.00599","test_object_zh":"游泳池水","methodology_zh":"化合氯浓度（计算值）"},{"_id":"6a8377f3af14b9c0e7b1fb32","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Stężenie ozonu","parameters":[{"name":"Zakres","range":"(0,03 – 2,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie ozonu\nZakres (0,03 – 2,0) mg/l\nMetoda spektrofotometryczna","reference":"Aplikacja kolorymetru Merck na podstawie testu Merck nr 1.00607","norm_bases":["Aplikacja kolorymetru Merck na podstawie testu Merck nr 1.00607"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Stężenie ozonu\nZakres (0,03 – 2,0) mg/l\nMetoda spektrofotometryczna Aplikacja kolorymetru Merck na podstawie testu Merck nr 1.00607 Woda na plywalniach Stezenie ozonu\nZakres (0,03 – 2,0) mg/l\nMetoda spektrofotometryczna Aplikacja kolorymetru Merck na podstawie testu Merck nr 1.00607","categories":["water"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ozone concentration","parameters_en":[{"name":"Range","range":"(0,03 – 2,0) mg/l"}],"search_en":"Swimming pool water Ozone concentration Spectrophotometric method Range Aplikacja kolorymetru Merck na podstawie testu Merck nr 1.00607","technique_en":"Spectrophotometric method","test_object_en":"Swimming pool water","parameters_zh":[{"name":"范围","range":"(0,03 – 2,0) mg/l"}],"search_zh":"游泳池水 臭氧浓度 分光光度法 范围 Aplikacja kolorymetru Merck na podstawie testu Merck nr 1.00607","technique_zh":"分光光度法","test_object_zh":"游泳池水","methodology_zh":"臭氧浓度"},{"_id":"6a8377f3af14b9c0e7b1fb33","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Potencjał utleniająco-redukujący (redoks) wzgl. Ag/AgCl 3,5 mol/l KCl","parameters":[{"name":"Zakres","range":"(220 – 850) mV"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"Potencjał utleniająco-redukujący (redoks) wzgl. Ag/AgCl 3,5 mol/l KCl\nZakres (220 – 850) mV\nMetoda potencjometryczna","reference":"USGS-OWQ: NFM 6.5","norm_bases":["USGS-OWQ: NFM 6.5"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Potencjał utleniająco-redukujący (redoks) wzgl. Ag/AgCl 3,5 mol/l KCl\nZakres (220 – 850) mV\nMetoda potencjometryczna USGS-OWQ: NFM 6.5 Woda na plywalniach Potencjal utleniajaco-redukujacy (redoks) wzgl. Ag/AgCl 3,5 mol/l KCl\nZakres (220 – 850) mV\nMetoda potencjometryczna USGS-OWQ: NFM 6.5","categories":["water"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Oxidation-reduction (redox) potential vs. Ag/AgCl 3,5 mol/l KCl","parameters_en":[{"name":"Range","range":"(220 – 850) mV"}],"search_en":"Swimming pool water Oxidation-reduction (redox) potential vs. Ag/AgCl 3,5 mol/l KCl Potentiometric method Range USGS-OWQ: NFM 6.5","technique_en":"Potentiometric method","test_object_en":"Swimming pool water","parameters_zh":[{"name":"范围","range":"(220 – 850) mV"}],"search_zh":"游泳池水 氧化还原电位（redoks），相对于 Ag/AgCl 3,5 mol/l KCl 电位法 范围 USGS-OWQ: NFM 6.5","technique_zh":"电位法","test_object_zh":"游泳池水","methodology_zh":"氧化还原电位（redoks），相对于 Ag/AgCl 3,5 mol/l KCl"},{"_id":"6a8377f3af14b9c0e7b1fb34","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda","methodology":"Pobieranie próbek do badań chemicznych i fizycznych (w tym sensorycznych)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych (w tym sensorycznych)","reference":"PN-ISO 5667-5:2017-10","norm_bases":["PN-ISO 5667-5:2017-10"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda Pobieranie próbek do badań chemicznych i fizycznych (w tym sensorycznych) PN-ISO 5667-5:2017-10 Woda do spozycia przez ludzi, woda Pobieranie probek do badan chemicznych i fizycznych (w tym sensorycznych) PN-ISO 5667-5:2017-10","categories":["water"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing (including sensory testing)","search_en":"Water intended for human consumption, water Sampling for chemical and physical testing (including sensory testing) PN-ISO 5667-5:2017-10","test_object_en":"Water intended for human consumption, water","search_zh":"生活饮用水、水 化学和物理检测采样（含感官检测） PN-ISO 5667-5:2017-10","test_object_zh":"生活饮用水、水","methodology_zh":"化学和物理检测采样（含感官检测）"},{"_id":"6a8377f3af14b9c0e7b1fb35","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PO-03/IR-07 wydanie 11 z dnia 30.01.2026 r.","norm_bases":["PO-03/IR-07 wydanie 11 z dnia 30.01.2026 r."],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Pobieranie próbek do badań chemicznych i fizycznych PO-03/IR-07 wydanie 11 z dnia 30.01.2026 r. Woda na plywalniach Pobieranie probek do badan chemicznych i fizycznych PO-03/IR-07 wydanie 11 z dnia 30.01.2026 r.","categories":["water"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Swimming pool water Sampling for chemical and physical testing PO-03/IR-07 wydanie 11 z dnia 30.01.2026 r.","test_object_en":"Swimming pool water","methodology_zh":"化学与物理检测用样品采集","search_zh":"游泳池水 化学与物理检测用样品采集 PO-03/IR-07 wydanie 11 z dnia 30.01.2026 r.","test_object_zh":"游泳池水"},{"_id":"6a8377f3af14b9c0e7b1fb36","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Przetwory zbożowe, Makaron","methodology":"Obecność zanieczyszczeń biologicznych, w tym szkodników i ich pozostałości","parameters":[],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Obecność zanieczyszczeń biologicznych, w tym szkodników i ich pozostałości\nMetoda wizualna","reference":"PN-A-74016:1974 z wyłączeniem p.2.4.2, p. 2.5 i p.2.6 | PN-A-74130:1993 p. 3.8","norm_bases":["PN-A-74016:1974 z wyłączeniem p.2.4.2, p. 2.5 i p.2.6","PN-A-74130:1993 p. 3.8"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przetwory zbożowe, Makaron Obecność zanieczyszczeń biologicznych, w tym szkodników i ich pozostałości\nMetoda wizualna PN-A-74016:1974 z wyłączeniem p.2.4.2, p. 2.5 i p.2.6 | PN-A-74130:1993 p. 3.8 Przetwory zbozowe, Makaron Obecnosc zanieczyszczen biologicznych, w tym szkodnikow i ich pozostalosci\nMetoda wizualna PN-A-74016:1974 z wylaczeniem p.2.4.2, p. 2.5 i p.2.6 | PN-A-74130:1993 p. 3.8","categories":["other"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of biological impurities, including pests and their residues","search_en":"Presence of biological impurities, including pests and their residues Visual method PN-A-74016:1974 z wyłączeniem p.2.4.2, p. 2.5 i p.2.6 | PN-A-74130:1993 p. 3.8","technique_en":"Visual method","search_zh":"目视法 PN-A-74016:1974 z wyłączeniem p.2.4.2, p. 2.5 i p.2.6 | PN-A-74130:1993 p. 3.8","technique_zh":"目视法"},{"_id":"6a8377f3af14b9c0e7b1fb37","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Przetwory zbożowe, Makaron, Przetwory owocowo-warzywne, Miód sztuczny płynny, Przyprawy i zioła, Mleko modyfikowane i mieszanki dla niemowląt typu Laktovit, Surowce zielarskie, Susze owocowe i warzywne","methodology":"Zawartość zanieczyszczeń (z wyłączeniem ferromagnetycznych)","parameters":[{"name":"Zakres","range":"(0,01 – 0,3) % (m/m)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość zanieczyszczeń (z wyłączeniem ferromagnetycznych)\nZakres (0,01 – 0,3) % (m/m)\nMetoda wagowa","reference":"PB-18 wydanie 5 z dnia 20.02.2020 r.","norm_bases":["PB-18 wydanie 5 z dnia 20.02.2020 r."],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przetwory zbożowe, Makaron, Przetwory owocowo-warzywne, Miód sztuczny płynny, Przyprawy i zioła, Mleko modyfikowane i mieszanki dla niemowląt typu Laktovit, Surowce zielarskie, Susze owocowe i warzywne Zawartość zanieczyszczeń (z wyłączeniem ferromagnetycznych)\nZakres (0,01 – 0,3) % (m/m)\nMetoda wagowa PB-18 wydanie 5 z dnia 20.02.2020 r. Przetwory zbozowe, Makaron, Przetwory owocowo-warzywne, Miod sztuczny plynny, Przyprawy i ziola, Mleko modyfikowane i mieszanki dla niemowlat typu Laktovit, Surowce zielarskie, Susze owocowe i warzywne Zawartosc zanieczyszczen (z wylaczeniem ferromagnetycznych)\nZakres (0,01 – 0,3) % (m/m)\nMetoda wagowa PB-18 wydanie 5 z dnia 20.02.2020 r.","categories":["food"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of impurities (excluding ferromagnetic)","parameters_en":[{"name":"Range","range":"(0,01 – 0,3) % (m/m)"}],"search_en":"Cereal products, Pasta, Fruit-vegetable products, Liquid artificial honey, Spices and herbs, Modified milk and infant formulae of the Laktovit type, Herbal raw materials, Dried fruit and vegetables Content of impurities (excluding ferromagnetic) Gravimetric method Range PB-18 wydanie 5 z dnia 20.02.2020 r.","technique_en":"Gravimetric method","test_object_en":"Cereal products, Pasta, Fruit-vegetable products, Liquid artificial honey, Spices and herbs, Modified milk and infant formulae of the Laktovit type, Herbal raw materials, Dried fruit and vegetables","parameters_zh":[{"name":"范围","range":"(0,01 – 0,3) % (m/m)"}],"search_zh":"重量法 范围 PB-18 wydanie 5 z dnia 20.02.2020 r.","technique_zh":"重量法"},{"_id":"6a8377f3af14b9c0e7b1fb38","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Przetwory zbożowe, Makaron, Przetwory owocowo-warzywne, Miód sztuczny płynny, Przyprawy i zioła, Mleko modyfikowane i mieszanki dla niemowląt typu Laktovit, Surowce zielarskie, Susze owocowe i warzywne","methodology":"Zawartość zanieczyszczeń","parameters":[],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Zawartość zanieczyszczeń\nMetoda wizualna","reference":"PB-18 wydanie 5 z dnia 20.02.2020 r.","norm_bases":["PB-18 wydanie 5 z dnia 20.02.2020 r."],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przetwory zbożowe, Makaron, Przetwory owocowo-warzywne, Miód sztuczny płynny, Przyprawy i zioła, Mleko modyfikowane i mieszanki dla niemowląt typu Laktovit, Surowce zielarskie, Susze owocowe i warzywne Zawartość zanieczyszczeń\nMetoda wizualna PB-18 wydanie 5 z dnia 20.02.2020 r. Przetwory zbozowe, Makaron, Przetwory owocowo-warzywne, Miod sztuczny plynny, Przyprawy i ziola, Mleko modyfikowane i mieszanki dla niemowlat typu Laktovit, Surowce zielarskie, Susze owocowe i warzywne Zawartosc zanieczyszczen\nMetoda wizualna PB-18 wydanie 5 z dnia 20.02.2020 r.","categories":["food"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Impurity content","search_en":"Cereal products, Pasta, Fruit-vegetable products, Liquid artificial honey, Spices and herbs, Modified milk and infant formulae of the Laktovit type, Herbal raw materials, Dried fruit and vegetables Impurity content Visual method PB-18 wydanie 5 z dnia 20.02.2020 r.","technique_en":"Visual method","test_object_en":"Cereal products, Pasta, Fruit-vegetable products, Liquid artificial honey, Spices and herbs, Modified milk and infant formulae of the Laktovit type, Herbal raw materials, Dried fruit and vegetables","search_zh":"杂质含量 目视法 PB-18 wydanie 5 z dnia 20.02.2020 r.","technique_zh":"目视法","methodology_zh":"杂质含量"},{"_id":"6a8377f3af14b9c0e7b1fb39","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Środowisko pracy - hałas","methodology":"Równoważny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(55 – 135) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A\nZakres (55 – 135) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 – p. 10 i strategię 3 – p.11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 – p. 10 i strategię 3 – p.11"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - hałas Równoważny poziom dźwięku A\nZakres (55 – 135) dB\nMetoda pomiarowa bezpośrednia PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 – p. 10 i strategię 3 – p.11 Srodowisko pracy - halas Rownowazny poziom dzwieku A\nZakres (55 – 135) dB\nMetoda pomiarowa bezposrednia PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wylaczeniem metody obejmujacej strategie 2 – p. 10 i strategie 3 – p.11","categories":["environment"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound pressure level","parameters_en":[{"name":"Range","range":"(55 – 135) dB"}],"search_en":"Workplace environment - noise A-weighted equivalent sound pressure level Direct measurement method Range PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 – p. 10 i strategię 3 – p.11","technique_en":"Direct measurement method","test_object_en":"Workplace environment - noise","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"范围","range":"(55 – 135) dB"}],"search_zh":"工作场所环境 — 噪声 A 计权等效声级 直接测量法 范围 PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 – p. 10 i strategię 3 – p.11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a8377f3af14b9c0e7b1fb3a","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Środowisko pracy - hałas","methodology":"Maksymalny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(55 – 135) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Maksymalny poziom dźwięku A\nZakres (55 – 135) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 – p. 10 i strategię 3 – p.11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 – p. 10 i strategię 3 – p.11"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - hałas Maksymalny poziom dźwięku A\nZakres (55 – 135) dB\nMetoda pomiarowa bezpośrednia PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 – p. 10 i strategię 3 – p.11 Srodowisko pracy - halas Maksymalny poziom dzwieku A\nZakres (55 – 135) dB\nMetoda pomiarowa bezposrednia PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wylaczeniem metody obejmujacej strategie 2 – p. 10 i strategie 3 – p.11","categories":["environment"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Maximum A-weighted sound pressure level","parameters_en":[{"name":"Range","range":"(55 – 135) dB"}],"search_en":"Workplace environment - noise Maximum A-weighted sound pressure level Direct measurement method Range PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 – p. 10 i strategię 3 – p.11","technique_en":"Direct measurement method","test_object_en":"Workplace environment - noise","parameters_zh":[{"name":"范围","range":"(55 – 135) dB"}],"search_zh":"工作场所环境 — 噪声 A 计权最大声级 直接测量法 范围 PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 – p. 10 i strategię 3 – p.11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 噪声","methodology_zh":"A 计权最大声级"},{"_id":"6a8377f3af14b9c0e7b1fb3b","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Środowisko pracy - hałas","methodology":"Szczytowy poziom dźwięku C","parameters":[{"name":"Zakres","range":"(55 – 138) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Szczytowy poziom dźwięku C\nZakres (55 – 138) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 – p. 10 i strategię 3 – p.11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 – p. 10 i strategię 3 – p.11"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - hałas Szczytowy poziom dźwięku C\nZakres (55 – 138) dB\nMetoda pomiarowa bezpośrednia PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 – p. 10 i strategię 3 – p.11 Srodowisko pracy - halas Szczytowy poziom dzwieku C\nZakres (55 – 138) dB\nMetoda pomiarowa bezposrednia PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wylaczeniem metody obejmujacej strategie 2 – p. 10 i strategie 3 – p.11","categories":["environment"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"C-weighted peak sound pressure level","parameters_en":[{"name":"Range","range":"(55 – 138) dB"}],"search_en":"Workplace environment - noise C-weighted peak sound pressure level Direct measurement method Range PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 – p. 10 i strategię 3 – p.11","technique_en":"Direct measurement method","test_object_en":"Workplace environment - noise","methodology_zh":"C 计权峰值声级","parameters_zh":[{"name":"范围","range":"(55 – 138) dB"}],"search_zh":"工作场所环境 — 噪声 C 计权峰值声级 直接测量法 范围 PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 – p. 10 i strategię 3 – p.11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a8377f3af14b9c0e7b1fb3c","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Środowisko pracy - hałas","methodology":"Poziom ekspozycji na hałas odniesiony do:","parameters":[{"name":"8-godz. dobowego wymiaru czasu pracy","range":null},{"name":"przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","range":null}],"technique":null,"techniques":[],"computed":[],"activity":"Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 – p. 10 i strategię 3 – p.11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 – p. 10 i strategię 3 – p.11"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - hałas Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 – p. 10 i strategię 3 – p.11 Srodowisko pracy - halas Poziom ekspozycji na halas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzecietnego tygodniowego wymiaru czasu pracy (z obliczen) PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wylaczeniem metody obejmujacej strategie 2 – p. 10 i strategie 3 – p.11","categories":["environment"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Noise exposure level referred to:","parameters_en":[{"name":"an 8-hour daily working time","range":null},{"name":"the average weekly working time (calculated)","range":null}],"search_en":"Workplace environment - noise Noise exposure level referred to: an 8-hour daily working time the average weekly working time (calculated) PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 – p. 10 i strategię 3 – p.11","test_object_en":"Workplace environment - noise","methodology_zh":"噪声暴露级，参照：","parameters_zh":[{"name":"8 小时日工作时间","range":null},{"name":"平均每周工作时间（计算值）","range":null}],"search_zh":"工作场所环境 — 噪声 噪声暴露级，参照： 8 小时日工作时间 平均每周工作时间（计算值） PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 – p. 10 i strategię 3 – p.11","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a8377f3af14b9c0e7b1fb3d","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Środowisko pracy - drgania działające na organizm człowieka przez kończyny górne","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","parameters":[{"name":"Zakres","range":"(0,2 – 50) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,2 – 50) m/s2\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-2:2004/A1:2015-11"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - drgania działające na organizm człowieka przez kończyny górne Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,2 – 50) m/s2\nMetoda pomiarowa bezpośrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 Srodowisko pracy - drgania dzialajace na organizm czlowieka przez konczyny gorne Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres (0,2 – 50) m/s2\nMetoda pomiarowa bezposrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","categories":["environment"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Frequency-weighted r.m.s. vibration acceleration","parameters_en":[{"name":"Range","range":"(0,2 – 50) m/s2"}],"search_en":"Workplace environment - hand-arm vibration Frequency-weighted r.m.s. vibration acceleration Direct measurement method Range PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","technique_en":"Direct measurement method","test_object_en":"Workplace environment - hand-arm vibration","methodology_zh":"频率计权振动加速度有效值","parameters_zh":[{"name":"范围","range":"(0,2 – 50) m/s2"}],"search_zh":"工作场所环境 — 手传振动 频率计权振动加速度有效值 直接测量法 范围 PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 手传振动"},{"_id":"6a8377f3af14b9c0e7b1fb3e","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Środowisko pracy - drgania działające na organizm człowieka przez kończyny górne","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-2:2004/A1:2015-11"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - drgania działające na organizm człowieka przez kończyny górne Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 Srodowisko pracy - drgania dzialajace na organizm czlowieka przez konczyny gorne Ekspozycja dzienna, wyrazona w postaci rownowaznej energetycznie dla 8-godzin dzialania sumy wektorowej skutecznych, skorygowanych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz) Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci sumy wektorowej skutecznych, wazonych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz) (z obliczen) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","categories":["environment"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Daily exposure, expressed as the energy-equivalent for 8 hours of the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for the three directional components (ahwx, ahwy, ahwz) Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for the three directional components (ahwx, ahwy, ahwz) (calculated)","search_en":"Workplace environment - hand-arm vibration Daily exposure, expressed as the energy-equivalent for 8 hours of the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for the three directional components (ahwx, ahwy, ahwz) Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for the three directional components (ahwx, ahwy, ahwz) (calculated) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","test_object_en":"Workplace environment - hand-arm vibration","search_zh":"工作场所环境 — 手传振动 日暴露量，以三个方向分量（ahwx、ahwy、ahwz）所测定的频率计权有效振动加速度矢量和的8小时能量等效值表示；持续30分钟及以下的暴露量，以三个方向分量（ahwx、ahwy、ahwz）所测定的频率计权有效振动加速度矢量和表示（由计算得出） PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","test_object_zh":"工作场所环境 — 手传振动","methodology_zh":"日暴露量，以三个方向分量（ahwx、ahwy、ahwz）所测定的频率计权有效振动加速度矢量和的8小时能量等效值表示；持续30分钟及以下的暴露量，以三个方向分量（ahwx、ahwy、ahwz）所测定的频率计权有效振动加速度矢量和表示（由计算得出）"},{"_id":"6a8377f3af14b9c0e7b1fb3f","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Środowisko pracy - drgania o ogólnym działaniu na organizm człowieka","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","parameters":[{"name":"Zakres","range":"(0,02 – 50) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,02 – 50) m/s2\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 14253+ A1:2011","norm_bases":["PN-EN 14253+ A1:2011"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - drgania o ogólnym działaniu na organizm człowieka Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,02 – 50) m/s2\nMetoda pomiarowa bezpośrednia PN-EN 14253+ A1:2011 Srodowisko pracy - drgania o ogolnym dzialaniu na organizm czlowieka Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres (0,02 – 50) m/s2\nMetoda pomiarowa bezposrednia PN-EN 14253+ A1:2011","categories":["environment"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Frequency-weighted r.m.s. vibration acceleration","parameters_en":[{"name":"Range","range":"(0,02 – 50) m/s2"}],"search_en":"Workplace environment - whole-body vibration Frequency-weighted r.m.s. vibration acceleration Direct measurement method Range PN-EN 14253+ A1:2011","technique_en":"Direct measurement method","test_object_en":"Workplace environment - whole-body vibration","methodology_zh":"频率计权振动加速度有效值","parameters_zh":[{"name":"范围","range":"(0,02 – 50) m/s2"}],"search_zh":"工作场所环境 — 全身振动 频率计权振动加速度有效值 直接测量法 范围 PN-EN 14253+ A1:2011","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 全身振动"},{"_id":"6a8377f3af14b9c0e7b1fb40","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Środowisko pracy - drgania o ogólnym działaniu na organizm człowieka","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz) Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz) Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz) (z obliczeń)","reference":"PN-EN 14253+ A1:2011","norm_bases":["PN-EN 14253+ A1:2011"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - drgania o ogólnym działaniu na organizm człowieka Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz) Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz) (z obliczeń) PN-EN 14253+ A1:2011 Srodowisko pracy - drgania o ogolnym dzialaniu na organizm czlowieka Ekspozycja dzienna, wyrazona w postaci rownowaznego energetycznie dla 8-godzin dzialania skutecznego, skorygowanego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1,4awx, 1,4awy, awz) Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci skutecznego, wazonego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1,4awx, 1,4awy, awz) (z obliczen) PN-EN 14253+ A1:2011","categories":["environment"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Daily exposure, expressed as the 8-hour energy-equivalent frequency-weighted RMS vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate coefficients (1,4awx, 1,4awy, awz) Exposure lasting 30 minutes and less, expressed as the frequency-weighted RMS vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate coefficients (1,4awx, 1,4awy, awz) (calculated)","search_en":"Workplace environment - whole-body vibration Daily exposure, expressed as the 8-hour energy-equivalent frequency-weighted RMS vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate coefficients (1,4awx, 1,4awy, awz) Exposure lasting 30 minutes and less, expressed as the frequency-weighted RMS vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate coefficients (1,4awx, 1,4awy, awz) (calculated) PN-EN 14253+ A1:2011","test_object_en":"Workplace environment - whole-body vibration","search_zh":"工作场所环境 — 全身振动 PN-EN 14253+ A1:2011","test_object_zh":"工作场所环境 — 全身振动"},{"_id":"6a8377f3af14b9c0e7b1fb41","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie elektryczne we wnętrzach","methodology":"Natężenie oświetlenia elektrycznego","parameters":[{"name":"Zakres","range":"(5 – 5 000) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie oświetlenia elektrycznego\nZakres (5 – 5 000) lx\nMetoda pomiarowa bezpośrednia","reference":"PN-83/E-04040.03","norm_bases":["PN-83/E-04040.03"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie elektryczne we wnętrzach Natężenie oświetlenia elektrycznego\nZakres (5 – 5 000) lx\nMetoda pomiarowa bezpośrednia PN-83/E-04040.03 Srodowisko pracy - oswietlenie elektryczne we wnetrzach Natezenie oswietlenia elektrycznego\nZakres (5 – 5 000) lx\nMetoda pomiarowa bezposrednia PN-83/E-04040.03","categories":["environment"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electric lighting illuminance","parameters_en":[{"name":"Range","range":"(5 – 5 000) lx"}],"search_en":"Workplace environment - indoor electric lighting Electric lighting illuminance Direct measurement method Range PN-83/E-04040.03","technique_en":"Direct measurement method","test_object_en":"Workplace environment - indoor electric lighting","parameters_zh":[{"name":"范围","range":"(5 – 5 000) lx"}],"search_zh":"工作场所环境 — 室内电气照明 电气照明的照度 直接测量法 范围 PN-83/E-04040.03","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 室内电气照明","methodology_zh":"电气照明的照度"},{"_id":"6a8377f3af14b9c0e7b1fb42","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie elektryczne we wnętrzach","methodology":"Równomierność oświetlenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równomierność oświetlenia (z obliczeń)","reference":"PN-83/E-04040.03","norm_bases":["PN-83/E-04040.03"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie elektryczne we wnętrzach Równomierność oświetlenia (z obliczeń) PN-83/E-04040.03 Srodowisko pracy - oswietlenie elektryczne we wnetrzach Rownomiernosc oswietlenia (z obliczen) PN-83/E-04040.03","categories":["environment"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance uniformity (calculated)","search_en":"Workplace environment - indoor electric lighting Illuminance uniformity (calculated) PN-83/E-04040.03","test_object_en":"Workplace environment - indoor electric lighting","methodology_zh":"照度均匀度（计算值）","search_zh":"工作场所环境 — 室内电气照明 照度均匀度（计算值） PN-83/E-04040.03","test_object_zh":"工作场所环境 — 室内电气照明"},{"_id":"6a8377f3af14b9c0e7b1fb43","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Pobieranie próbek do oceny narażenia zawodowego na:","parameters":[{"name":"czynniki pyłowe frakcja wdychalna frakcja respirabilna","range":null},{"name":"substancje organiczne, w tym frakcja wdychalna","range":null},{"name":"metale i ich związki, w tym frakcja wdychalna frakcja respirabilna","range":null}],"technique":"Metoda dozymetrii indywidualnej","techniques":["Metoda dozymetrii indywidualnej"],"computed":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe frakcja wdychalna frakcja respirabilna\nsubstancje organiczne, w tym frakcja wdychalna\nmetale i ich związki, w tym frakcja wdychalna frakcja respirabilna\nMetoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002+Az1:2004"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe frakcja wdychalna frakcja respirabilna\nsubstancje organiczne, w tym frakcja wdychalna\nmetale i ich związki, w tym frakcja wdychalna frakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy - powietrze Pobieranie probek do oceny narazenia zawodowego na:\nZakres:\nczynniki pylowe frakcja wdychalna frakcja respirabilna\nsubstancje organiczne, w tym frakcja wdychalna\nmetale i ich zwiazki, w tym frakcja wdychalna frakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002+Az1:2004","categories":["materials","environment"],"row_index":55,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for the assessment of occupational exposure to:","parameters_en":[{"name":"dust agents inhalable fraction respirable fraction","range":null},{"name":"organic substances, including inhalable fraction","range":null},{"name":"metals and their compounds, including inhalable fraction respirable fraction","range":null}],"search_en":"Workplace environment - air Sampling for the assessment of occupational exposure to: Personal dosimetry method dust agents inhalable fraction respirable fraction organic substances, including inhalable fraction metals and their compounds, including inhalable fraction respirable fraction PN-Z-04008-7:2002+Az1:2004","technique_en":"Personal dosimetry method","test_object_en":"Workplace environment - air","methodology_zh":"职业接触评估采样，针对：","search_zh":"工作场所环境 — 空气 职业接触评估采样，针对： 个体剂量测定法 粉尘因子 可吸入性粉尘 呼吸性粉尘 有机物质，其中包括可吸入性粉尘 金属及其化合物，其中包括 可吸入性粉尘 呼吸性粉尘 PN-Z-04008-7:2002+Az1:2004","technique_zh":"个体剂量测定法","test_object_zh":"工作场所环境 — 空气","parameters_zh":[{"name":"粉尘因子 可吸入性粉尘 呼吸性粉尘","range":null},{"name":"有机物质，其中包括可吸入性粉尘","range":null},{"name":"金属及其化合物，其中包括 可吸入性粉尘 呼吸性粉尘","range":null}]},{"_id":"6a8377f3af14b9c0e7b1fb44","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Pobieranie próbek do oceny narażenia zawodowego na:","parameters":[{"name":"substancje nieorganiczne, w tym frakcja wdychalna frakcja respirabilna","range":null}],"technique":"Metoda dozymetrii indywidualnej; Metoda stacjonarna","techniques":["Metoda dozymetrii indywidualnej","Metoda stacjonarna"],"computed":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na:\nsubstancje nieorganiczne, w tym frakcja wdychalna frakcja respirabilna\nMetoda dozymetrii indywidualnej; Metoda stacjonarna","reference":"PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002+Az1:2004"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Pobieranie próbek do oceny narażenia zawodowego na:\nsubstancje nieorganiczne, w tym frakcja wdychalna frakcja respirabilna\nMetoda dozymetrii indywidualnej; Metoda stacjonarna PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy - powietrze Pobieranie probek do oceny narazenia zawodowego na:\nsubstancje nieorganiczne, w tym frakcja wdychalna frakcja respirabilna\nMetoda dozymetrii indywidualnej; Metoda stacjonarna PN-Z-04008-7:2002+Az1:2004","categories":["environment"],"row_index":56,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for the assessment of occupational exposure to:","parameters_en":[{"name":"inorganic substances, including inhalable fraction respirable fraction","range":null}],"search_en":"Workplace environment - air Sampling for the assessment of occupational exposure to: Personal dosimetry method; Stationary method inorganic substances, including inhalable fraction respirable fraction PN-Z-04008-7:2002+Az1:2004","technique_en":"Personal dosimetry method; Stationary method","test_object_en":"Workplace environment - air","methodology_zh":"职业接触评估采样，针对：","search_zh":"工作场所环境 — 空气 职业接触评估采样，针对： 个体剂量测定法；定点测定法 PN-Z-04008-7:2002+Az1:2004","test_object_zh":"工作场所环境 — 空气","technique_zh":"个体剂量测定法；定点测定法"},{"_id":"6a8377f3af14b9c0e7b1fb45","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Wskaźnik narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002+Az1:2004"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Wskaźnik narażenia (z obliczeń) PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy - powietrze Wskaznik narazenia (z obliczen) PN-Z-04008-7:2002+Az1:2004","categories":["environment"],"row_index":57,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Exposure index (calculated)","search_en":"Workplace environment - air Exposure index (calculated) PN-Z-04008-7:2002+Az1:2004","test_object_en":"Workplace environment - air","methodology_zh":"暴露指数（计算得出）","search_zh":"工作场所环境 — 空气 暴露指数（计算得出） PN-Z-04008-7:2002+Az1:2004","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a8377f3af14b9c0e7b1fb46","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna","parameters":[{"name":"Apatyty i fosforyty","range":null},{"name":"Cement portlandzki","range":null},{"name":"Ditlenek tytanu","range":null},{"name":"Grafit naturalny","range":null},{"name":"Grafit syntetyczny","range":null},{"name":"Kaolin","range":null},{"name":"Krzemionka bezpostaciowa i syntetyczna","range":null},{"name":"Pyły drewna","range":null},{"name":"Pyły mąki","range":null},{"name":"Pyły niesklasyfikowane ze względu na toksyczność","range":null},{"name":"Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki","range":null},{"name":"Siarczan (VI) wapnia (gips)","range":null},{"name":"Sadza techniczna","range":null},{"name":"Węgiel (kamienny, brunatny)","range":null},{"name":"Węglan magnezu wapnia (dolomit)","range":null},{"name":"Węglik krzemu, niewłóknisty","range":null},{"name":"Zakres","range":"(0,15 – 17,0) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna\nZakres:\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna\nPyły drewna\nPyły mąki\nPyły niesklasyfikowane ze względu na toksyczność\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nWęgiel (kamienny, brunatny)\nWęglan magnezu wapnia (dolomit)\nWęglik krzemu, niewłóknisty\nZakres (0,15 – 17,0) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04507:2022-05","PN-Z-04507:2022-05/Ap1:2022-08"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna\nZakres:\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna\nPyły drewna\nPyły mąki\nPyły niesklasyfikowane ze względu na toksyczność\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nWęgiel (kamienny, brunatny)\nWęglan magnezu wapnia (dolomit)\nWęglik krzemu, niewłóknisty\nZakres (0,15 – 17,0) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08 Srodowisko pracy - powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia - frakcja wdychalna\nZakres:\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna\nPyly drewna\nPyly maki\nPyly niesklasyfikowane ze wzgledu na toksycznosc\nPyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nWegiel (kamienny, brunatny)\nWeglan magnezu wapnia (dolomit)\nWeglik krzemu, niewloknisty\nZakres (0,15 – 17,0) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":58,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of harmful dust agents - inhalable fraction","parameters_en":[{"name":"Apatites and phosphorites","range":null},{"name":"Portland cement","range":null},{"name":"Titanium dioxide","range":null},{"name":"Natural graphite","range":null},{"name":"Synthetic graphite","range":null},{"name":"Kaolin","range":null},{"name":"Amorphous and synthetic silica","range":null},{"name":"Wood dusts","range":null},{"name":"Flour dusts","range":null},{"name":"Dusts not classified according to toxicity","range":null},{"name":"Organic dusts of animal and plant origin, excluding wood and flour dusts","range":null},{"name":"Calcium sulfate (VI) (gypsum)","range":null},{"name":"Carbon black","range":null},{"name":"Coal (hard, brown)","range":null},{"name":"Calcium magnesium carbonate (dolomite)","range":null},{"name":"Silicon carbide, non-fibrous","range":null},{"name":"Range","range":"(0,15 – 17,0) mg/m3"}],"search_en":"Workplace environment - air Concentration of harmful dust agents - inhalable fraction Gravimetric method Apatites and phosphorites Portland cement Titanium dioxide Natural graphite Synthetic graphite Kaolin Amorphous and synthetic silica Wood dusts Flour dusts Dusts not classified according to toxicity Organic dusts of animal and plant origin, excluding wood and flour dusts Calcium sulfate (VI) (gypsum) Carbon black Coal (hard, brown) Calcium magnesium carbonate (dolomite) Silicon carbide, non-fibrous Range PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"磷灰石与磷块岩","range":null},{"name":"硅酸盐水泥","range":null},{"name":"二氧化钛","range":null},{"name":"天然石墨","range":null},{"name":"合成石墨","range":null},{"name":"高岭土","range":null},{"name":"无定形与合成二氧化硅","range":null},{"name":"木粉尘","range":null},{"name":"面粉粉尘","range":null},{"name":"未按毒性分类的粉尘","range":null},{"name":"动植物来源有机粉尘，木粉和面粉除外","range":null},{"name":"硫酸钙（VI）（石膏）","range":null},{"name":"炭黑","range":null},{"name":"煤（烟煤、褐煤）","range":null},{"name":"碳酸钙镁（白云石）","range":null},{"name":"碳化硅，非纤维状","range":null},{"name":"范围","range":"(0,15 – 17,0) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害粉尘因素浓度 — 可吸入组分 重量法 磷灰石与磷块岩 硅酸盐水泥 二氧化钛 天然石墨 合成石墨 高岭土 无定形与合成二氧化硅 木粉尘 面粉粉尘 未按毒性分类的粉尘 动植物来源有机粉尘，木粉和面粉除外 硫酸钙（VI）（石膏） 炭黑 煤（烟煤、褐煤） 碳酸钙镁（白云石） 碳化硅，非纤维状 范围 PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"有害粉尘因素浓度 — 可吸入组分"},{"_id":"6a8377f3af14b9c0e7b1fb47","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja respirabilna","parameters":[{"name":"Apatyty i fosforyty","range":null},{"name":"Cement portlandzki","range":null},{"name":"Grafit naturalny","range":null},{"name":"Krzemionka bezpostaciowa i syntetyczna","range":null},{"name":"Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki","range":null},{"name":"Węgiel (kamienny, brunatny)","range":null},{"name":"Zakres","range":"(0,10 – 6,2) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja respirabilna\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nWęgiel (kamienny, brunatny)\nZakres (0,10 – 6,2) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04508:2022-05","PN-Z-04508:2022-05/Ap1:2022-08"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja respirabilna\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nWęgiel (kamienny, brunatny)\nZakres (0,10 – 6,2) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08 Srodowisko pracy - powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia - frakcja respirabilna\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nWegiel (kamienny, brunatny)\nZakres (0,10 – 6,2) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":59,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of dust harmful to health - respirable fraction","parameters_en":[{"name":"Apatites and phosphorites","range":null},{"name":"Portland cement","range":null},{"name":"Natural graphite","range":null},{"name":"Amorphous and synthetic silica","range":null},{"name":"Organic dusts of animal and plant origin, excluding wood and flour dusts","range":null},{"name":"Coal (hard, brown)","range":null},{"name":"Range","range":"(0,10 – 6,2) mg/m3"}],"search_en":"Workplace environment - air Concentration of dust harmful to health - respirable fraction Gravimetric method Apatites and phosphorites Portland cement Natural graphite Amorphous and synthetic silica Organic dusts of animal and plant origin, excluding wood and flour dusts Coal (hard, brown) Range PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"磷灰石与磷块岩","range":null},{"name":"硅酸盐水泥","range":null},{"name":"天然石墨","range":null},{"name":"无定形与合成二氧化硅","range":null},{"name":"动植物来源有机粉尘，木粉和面粉除外","range":null},{"name":"煤（烟煤、褐煤）","range":null},{"name":"范围","range":"(0,10 – 6,2) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害粉尘因素浓度 — 呼吸性组分 重量法 磷灰石与磷块岩 硅酸盐水泥 天然石墨 无定形与合成二氧化硅 动植物来源有机粉尘，木粉和面粉除外 煤（烟煤、褐煤） 范围 PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"有害粉尘因素浓度 — 呼吸性组分"},{"_id":"6a8377f3af14b9c0e7b1fb48","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie tlenków żelaza – w przeliczeniu na Fe","parameters":[{"name":"frakcja wdychalna","range":null},{"name":"Zakres","range":"(0,028 – 13,9) mg/m3"},{"name":"frakcja respirabilna","range":null},{"name":"Zakres","range":"(0,025 – 12,6) mg/m3"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie tlenków żelaza – w przeliczeniu na Fe\nZakres:\nfrakcja wdychalna\nZakres (0,028 – 13,9) mg/m3\nfrakcja respirabilna\nZakres (0,025 – 12,6) mg/m3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04469:2025-02","norm_bases":["PN-Z-04469:2025-02"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie tlenków żelaza – w przeliczeniu na Fe\nZakres:\nfrakcja wdychalna\nZakres (0,028 – 13,9) mg/m3\nfrakcja respirabilna\nZakres (0,025 – 12,6) mg/m3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04469:2025-02 Srodowisko pracy - powietrze Stezenie tlenkow zelaza – w przeliczeniu na Fe\nZakres:\nfrakcja wdychalna\nZakres (0,028 – 13,9) mg/m3\nfrakcja respirabilna\nZakres (0,025 – 12,6) mg/m3\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04469:2025-02","categories":["environment"],"row_index":60,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of iron oxides – calculated as Fe","parameters_en":[{"name":"inhalable fraction","range":null},{"name":"Range","range":"(0,028 – 13,9) mg/m3"},{"name":"respirable fraction","range":null},{"name":"Range","range":"(0,025 – 12,6) mg/m3"}],"search_en":"Workplace environment - air Concentration of iron oxides – calculated as Fe Flame atomic absorption spectrometry (FAAS) inhalable fraction Range respirable fraction Range PN-Z-04469:2025-02","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"可吸入组分","range":null},{"name":"范围","range":"(0,028 – 13,9) mg/m3"},{"name":"呼吸性组分","range":null},{"name":"范围","range":"(0,025 – 12,6) mg/m3"}],"search_zh":"工作场所环境 — 空气 火焰原子吸收光谱法（FAAS） 可吸入组分 范围 呼吸性组分 范围 PN-Z-04469:2025-02","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a8377f3af14b9c0e7b1fb49","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie manganu i jego związków nieorganicznych w przeliczeniu na Mn","parameters":[{"name":"frakcja wdychalna","range":null},{"name":"Zakres","range":"(0,004 – 0,85) mg/m3"},{"name":"frakcja respirabilna","range":null},{"name":"Zakres","range":"(0,004 – 0,77) mg/m3"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie manganu i jego związków nieorganicznych w przeliczeniu na Mn\nZakres:\nfrakcja wdychalna\nZakres (0,004 – 0,85) mg/m3\nfrakcja respirabilna\nZakres (0,004 – 0,77) mg/m3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04472:2015-10 | PN-Z-04472:2015-10/Ap1:2015-12","norm_bases":["PN-Z-04472:2015-10","PN-Z-04472:2015-10/Ap1:2015-12"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie manganu i jego związków nieorganicznych w przeliczeniu na Mn\nZakres:\nfrakcja wdychalna\nZakres (0,004 – 0,85) mg/m3\nfrakcja respirabilna\nZakres (0,004 – 0,77) mg/m3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04472:2015-10 | PN-Z-04472:2015-10/Ap1:2015-12 Srodowisko pracy - powietrze Stezenie manganu i jego zwiazkow nieorganicznych w przeliczeniu na Mn\nZakres:\nfrakcja wdychalna\nZakres (0,004 – 0,85) mg/m3\nfrakcja respirabilna\nZakres (0,004 – 0,77) mg/m3\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04472:2015-10 | PN-Z-04472:2015-10/Ap1:2015-12","categories":["environment"],"row_index":61,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of manganese and its inorganic compounds calculated as Mn","parameters_en":[{"name":"inhalable fraction","range":null},{"name":"Range","range":"(0,004 – 0,85) mg/m3"},{"name":"respirable fraction","range":null},{"name":"Range","range":"(0,004 – 0,77) mg/m3"}],"search_en":"Workplace environment - air Concentration of manganese and its inorganic compounds calculated as Mn Flame atomic absorption spectrometry (FAAS) inhalable fraction Range respirable fraction Range PN-Z-04472:2015-10 | PN-Z-04472:2015-10/Ap1:2015-12","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"可吸入组分","range":null},{"name":"范围","range":"(0,004 – 0,85) mg/m3"},{"name":"呼吸性组分","range":null},{"name":"范围","range":"(0,004 – 0,77) mg/m3"}],"search_zh":"工作场所环境 — 空气 锰及其无机化合物浓度（以 Mn 计） 火焰原子吸收光谱法（FAAS） 可吸入组分 范围 呼吸性组分 范围 PN-Z-04472:2015-10 | PN-Z-04472:2015-10/Ap1:2015-12","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 — 空气","methodology_zh":"锰及其无机化合物浓度（以 Mn 计）"},{"_id":"6a8377f3af14b9c0e7b1fb4a","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie tlenku węgla","parameters":[{"name":"Zakres","range":"(2,32 – 290) mg/m3"},{"name":"Zakres","range":"(2 – 250) ppm"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Stężenie tlenku węgla\nZakres:\nZakres (2,32 – 290) mg/m3\nZakres (2 – 250) ppm\nMetoda elektrochemiczna","reference":"PB-33 wydanie 6 z dnia 03.02.2026 r","norm_bases":["PB-33 wydanie 6 z dnia 03.02.2026 r"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie tlenku węgla\nZakres:\nZakres (2,32 – 290) mg/m3\nZakres (2 – 250) ppm\nMetoda elektrochemiczna PB-33 wydanie 6 z dnia 03.02.2026 r Srodowisko pracy - powietrze Stezenie tlenku wegla\nZakres:\nZakres (2,32 – 290) mg/m3\nZakres (2 – 250) ppm\nMetoda elektrochemiczna PB-33 wydanie 6 z dnia 03.02.2026 r","categories":["environment"],"row_index":62,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Carbon monoxide concentration","parameters_en":[{"name":"Range","range":"(2,32 – 290) mg/m3"},{"name":"Range","range":"(2 – 250) ppm"}],"search_en":"Workplace environment - air Carbon monoxide concentration Electrochemical method Range Range PB-33 wydanie 6 z dnia 03.02.2026 r","technique_en":"Electrochemical method","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"范围","range":"(2,32 – 290) mg/m3"},{"name":"范围","range":"(2 – 250) ppm"}],"search_zh":"工作场所环境 — 空气 一氧化碳浓度 电化学法 范围 范围 PB-33 wydanie 6 z dnia 03.02.2026 r","technique_zh":"电化学法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"一氧化碳浓度"},{"_id":"6a8377f3af14b9c0e7b1fb4b","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Wskaźniki narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźniki narażenia (z obliczeń)","reference":"PB-33 wydanie 6 z dnia 03.02.2026 r","norm_bases":["PB-33 wydanie 6 z dnia 03.02.2026 r"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Wskaźniki narażenia (z obliczeń) PB-33 wydanie 6 z dnia 03.02.2026 r Srodowisko pracy - powietrze Wskazniki narazenia (z obliczen) PB-33 wydanie 6 z dnia 03.02.2026 r","categories":["environment"],"row_index":63,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Exposure indices (calculated)","search_en":"Workplace environment - air Exposure indices (calculated) PB-33 wydanie 6 z dnia 03.02.2026 r","test_object_en":"Workplace environment - air","search_zh":"工作场所环境 — 空气 暴露指数（计算值） PB-33 wydanie 6 z dnia 03.02.2026 r","test_object_zh":"工作场所环境 — 空气","methodology_zh":"暴露指数（计算值）"},{"_id":"6a8377f3af14b9c0e7b1fb4c","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie miedzi i jej związków nieorganicznych - w przeliczeniu na Cu","parameters":[{"name":"Zakres","range":"(0,02 – 2,5) mg/m3"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie miedzi i jej związków nieorganicznych - w przeliczeniu na Cu\nZakres (0,02 – 2,5) mg/m3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-79/Z-04106.02","norm_bases":["PN-79/Z-04106.02"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie miedzi i jej związków nieorganicznych - w przeliczeniu na Cu\nZakres (0,02 – 2,5) mg/m3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-79/Z-04106.02 Srodowisko pracy - powietrze Stezenie miedzi i jej zwiazkow nieorganicznych - w przeliczeniu na Cu\nZakres (0,02 – 2,5) mg/m3\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-79/Z-04106.02","categories":["environment"],"row_index":64,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of copper and its inorganic compounds - calculated as Cu","parameters_en":[{"name":"Range","range":"(0,02 – 2,5) mg/m3"}],"search_en":"Workplace environment - air Concentration of copper and its inorganic compounds - calculated as Cu Flame atomic absorption spectrometry (FAAS) Range PN-79/Z-04106.02","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"范围","range":"(0,02 – 2,5) mg/m3"}],"search_zh":"工作场所环境 — 空气 火焰原子吸收光谱法（FAAS） 范围 PN-79/Z-04106.02","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a8377f3af14b9c0e7b1fb4d","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie tlenku azotu","parameters":[{"name":"Zakres","range":"(0,24 – 15,4) mg/m3"},{"name":"Zakres","range":"(0,19 – 12,3) ppm"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie tlenku azotu\nZakres:\nZakres (0,24 – 15,4) mg/m3\nZakres (0,19 – 12,3) ppm\nMetoda spektrofotometryczna","reference":"PN-Z-04009-11:2008","norm_bases":["PN-Z-04009-11:2008"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie tlenku azotu\nZakres:\nZakres (0,24 – 15,4) mg/m3\nZakres (0,19 – 12,3) ppm\nMetoda spektrofotometryczna PN-Z-04009-11:2008 Srodowisko pracy - powietrze Stezenie tlenku azotu\nZakres:\nZakres (0,24 – 15,4) mg/m3\nZakres (0,19 – 12,3) ppm\nMetoda spektrofotometryczna PN-Z-04009-11:2008","categories":["environment"],"row_index":65,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrogen oxide concentration","parameters_en":[{"name":"Range","range":"(0,24 – 15,4) mg/m3"},{"name":"Range","range":"(0,19 – 12,3) ppm"}],"search_en":"Workplace environment - air Nitrogen oxide concentration Spectrophotometric method Range Range PN-Z-04009-11:2008","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"范围","range":"(0,24 – 15,4) mg/m3"},{"name":"范围","range":"(0,19 – 12,3) ppm"}],"search_zh":"工作场所环境 — 空气 一氧化氮浓度 分光光度法 范围 范围 PN-Z-04009-11:2008","technique_zh":"分光光度法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"一氧化氮浓度"},{"_id":"6a8377f3af14b9c0e7b1fb4e","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie ditlenku azotu","parameters":[{"name":"Zakres","range":"(0,07 – 3,95) mg/m3"},{"name":"Zakres","range":"(0,04 – 2,07) ppm"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie ditlenku azotu\nZakres:\nZakres (0,07 – 3,95) mg/m3\nZakres (0,04 – 2,07) ppm\nMetoda spektrofotometryczna","reference":"PN-Z-04009-11:2008","norm_bases":["PN-Z-04009-11:2008"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie ditlenku azotu\nZakres:\nZakres (0,07 – 3,95) mg/m3\nZakres (0,04 – 2,07) ppm\nMetoda spektrofotometryczna PN-Z-04009-11:2008 Srodowisko pracy - powietrze Stezenie ditlenku azotu\nZakres:\nZakres (0,07 – 3,95) mg/m3\nZakres (0,04 – 2,07) ppm\nMetoda spektrofotometryczna PN-Z-04009-11:2008","categories":["environment"],"row_index":66,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrogen dioxide concentration","parameters_en":[{"name":"Range","range":"(0,07 – 3,95) mg/m3"},{"name":"Range","range":"(0,04 – 2,07) ppm"}],"search_en":"Workplace environment - air Nitrogen dioxide concentration Spectrophotometric method Range Range PN-Z-04009-11:2008","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"范围","range":"(0,07 – 3,95) mg/m3"},{"name":"范围","range":"(0,04 – 2,07) ppm"}],"search_zh":"工作场所环境 — 空气 二氧化氮浓度 分光光度法 范围 范围 PN-Z-04009-11:2008","technique_zh":"分光光度法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"二氧化氮浓度"},{"_id":"6a8377f3af14b9c0e7b1fb4f","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie/ zawartość krystalicznej krzemionki (kwarc, krystobalit)","parameters":[{"name":"frakcja respirabilna","range":null},{"name":"Zakres","range":"(0,010 – 0,37) mg/m³"},{"name":"Zakres","range":"(10 – 400) μg w próbce"}],"technique":"Metoda spektrometrii w podczerwieni z transformacją Fouriera (FT-IR)","techniques":["Metoda spektrometrii w podczerwieni z transformacją Fouriera (FT-IR)"],"computed":[],"activity":"Stężenie/ zawartość krystalicznej krzemionki (kwarc, krystobalit)\nZakres:\nfrakcja respirabilna\nZakres (0,010 – 0,37) mg/m³\nZakres (10 – 400) μg w próbce\nMetoda spektrometrii w podczerwieni z transformacją Fouriera (FT-IR)","reference":"Podstawy i Metody Oceny Środowiska Pracy CIOP 2012, 4(74), str. 117-130","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy CIOP 2012, 4(74), str. 117-130"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie/ zawartość krystalicznej krzemionki (kwarc, krystobalit)\nZakres:\nfrakcja respirabilna\nZakres (0,010 – 0,37) mg/m³\nZakres (10 – 400) μg w próbce\nMetoda spektrometrii w podczerwieni z transformacją Fouriera (FT-IR) Podstawy i Metody Oceny Środowiska Pracy CIOP 2012, 4(74), str. 117-130 Srodowisko pracy - powietrze Stezenie/ zawartosc krystalicznej krzemionki (kwarc, krystobalit)\nZakres:\nfrakcja respirabilna\nZakres (0,010 – 0,37) mg/m³\nZakres (10 – 400) μg w probce\nMetoda spektrometrii w podczerwieni z transformacja Fouriera (FT-IR) Podstawy i Metody Oceny Srodowiska Pracy CIOP 2012, 4(74), str. 117-130","categories":["environment"],"row_index":67,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/ content of crystalline silica (quartz, cristobalite)","parameters_en":[{"name":"respirable fraction","range":null},{"name":"Range","range":"(0,010 – 0,37) mg/m³"},{"name":"Range","range":"(10 – 400) μg w próbce"}],"search_en":"Workplace environment - air Concentration/ content of crystalline silica (quartz, cristobalite) Fourier transform infrared spectrometry (FT-IR) respirable fraction Range Range Podstawy i Metody Oceny Środowiska Pracy CIOP 2012, 4(74), str. 117-130","technique_en":"Fourier transform infrared spectrometry (FT-IR)","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"呼吸性组分","range":null},{"name":"范围","range":"(0,010 – 0,37) mg/m³"},{"name":"范围","range":"(10 – 400) μg w próbce"}],"search_zh":"工作场所环境 — 空气 傅里叶变换红外光谱法（FT-IR） 呼吸性组分 范围 范围 Podstawy i Metody Oceny Środowiska Pracy CIOP 2012, 4(74), str. 117-130","test_object_zh":"工作场所环境 — 空气","technique_zh":"傅里叶变换红外光谱法（FT-IR）"},{"_id":"6a8377f3af14b9c0e7b1fb50","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda, woda na pływalniach, woda w kąpielisku, woda w miejscu wykorzystywanym do kąpieli","methodology":"Pobieranie próbek do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN- EN ISO 19458:2007","norm_bases":["PN- EN ISO 19458:2007"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Mikrobiologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda, woda na pływalniach, woda w kąpielisku, woda w miejscu wykorzystywanym do kąpieli Pobieranie próbek do badań mikrobiologicznych PN- EN ISO 19458:2007 Woda do spozycia przez ludzi, woda, woda na plywalniach, woda w kapielisku, woda w miejscu wykorzystywanym do kapieli Pobieranie probek do badan mikrobiologicznych PN- EN ISO 19458:2007","categories":["water","microbiology"],"row_index":68,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for microbiological testing","search_en":"Water intended for human consumption, water, swimming pool water, bathing water, water at a site used for bathing Sampling for microbiological testing PN- EN ISO 19458:2007","test_object_en":"Water intended for human consumption, water, swimming pool water, bathing water, water at a site used for bathing","methodology_zh":"微生物检测用样品采集","search_zh":"生活饮用水、水、游泳池水、浴场水、用于游泳场所的水 微生物检测用样品采集 PN- EN ISO 19458:2007","test_object_zh":"生活饮用水、水、游泳池水、浴场水、用于游泳场所的水"},{"_id":"6a8377f3af14b9c0e7b1fb51","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda, woda na pływalniach, woda w kąpielisku, woda w miejscu wykorzystywanym do kąpieli","methodology":"Ogólna liczba mikroorganizmów w temp. 36°C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w temp. 36°C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Mikrobiologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda, woda na pływalniach, woda w kąpielisku, woda w miejscu wykorzystywanym do kąpieli Ogólna liczba mikroorganizmów w temp. 36°C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda do spozycia przez ludzi, woda, woda na plywalniach, woda w kapielisku, woda w miejscu wykorzystywanym do kapieli Ogolna liczba mikroorganizmow w temp. 36°C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":69,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total viable count at 36°C","search_en":"Water intended for human consumption, water, swimming pool water, bathing water, water at a site used for bathing Total viable count at 36°C Plate method (pour plate) PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water intended for human consumption, water, swimming pool water, bathing water, water at a site used for bathing","search_zh":"生活饮用水、水、游泳池水、浴场水、用于游泳场所的水 36°C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","methodology_zh":"36°C 微生物总数","test_object_zh":"生活饮用水、水、游泳池水、浴场水、用于游泳场所的水"},{"_id":"6a8377f3af14b9c0e7b1fb52","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda, woda na pływalniach, woda w kąpielisku, woda w miejscu wykorzystywanym do kąpieli","methodology":"Ogólna liczba mikroorganizmów w temp. 22°C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w temp. 22°C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Mikrobiologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda, woda na pływalniach, woda w kąpielisku, woda w miejscu wykorzystywanym do kąpieli Ogólna liczba mikroorganizmów w temp. 22°C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda do spozycia przez ludzi, woda, woda na plywalniach, woda w kapielisku, woda w miejscu wykorzystywanym do kapieli Ogolna liczba mikroorganizmow w temp. 22°C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":70,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total viable count at 22°C","search_en":"Water intended for human consumption, water, swimming pool water, bathing water, water at a site used for bathing Total viable count at 22°C Plate method (pour plate) PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water intended for human consumption, water, swimming pool water, bathing water, water at a site used for bathing","methodology_zh":"22°C 微生物总数","search_zh":"生活饮用水、水、游泳池水、浴场水、用于游泳场所的水 22°C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"生活饮用水、水、游泳池水、浴场水、用于游泳场所的水"},{"_id":"6a8377f3af14b9c0e7b1fb53","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda, woda na pływalniach, woda w kąpielisku, woda w miejscu wykorzystywanym do kąpieli","methodology":"Liczba bakterii grupy coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Mikrobiologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda, woda na pływalniach, woda w kąpielisku, woda w miejscu wykorzystywanym do kąpieli Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda do spozycia przez ludzi, woda, woda na plywalniach, woda w kapielisku, woda w miejscu wykorzystywanym do kapieli Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":71,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Coliform bacteria count","search_en":"Water intended for human consumption, water, swimming pool water, bathing water, water at a site used for bathing Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption, water, swimming pool water, bathing water, water at a site used for bathing","methodology_zh":"大肠菌群计数","search_zh":"生活饮用水、水、游泳池水、浴场水、用于游泳场所的水 大肠菌群计数 膜过滤法 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"生活饮用水、水、游泳池水、浴场水、用于游泳场所的水"},{"_id":"6a8377f3af14b9c0e7b1fb54","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda, woda na pływalniach, woda w kąpielisku, woda w miejscu wykorzystywanym do kąpieli","methodology":"Liczba Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Mikrobiologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda, woda na pływalniach, woda w kąpielisku, woda w miejscu wykorzystywanym do kąpieli Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda do spozycia przez ludzi, woda, woda na plywalniach, woda w kapielisku, woda w miejscu wykorzystywanym do kapieli Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":72,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Escherichia coli count","search_en":"Water intended for human consumption, water, swimming pool water, bathing water, water at a site used for bathing Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption, water, swimming pool water, bathing water, water at a site used for bathing","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"生活饮用水、水、游泳池水、浴场水、用于游泳场所的水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"生活饮用水、水、游泳池水、浴场水、用于游泳场所的水"},{"_id":"6a8377f3af14b9c0e7b1fb55","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda, woda na pływalniach, woda w kąpielisku, woda w miejscu wykorzystywanym do kąpieli","methodology":"Najbardziej prawdopodobna liczba bakterii grupy coli","parameters":[],"technique":"Metoda NPL (Colilert - 18)","techniques":["Metoda NPL (Colilert - 18)"],"computed":[],"activity":"Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL (Colilert - 18)","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Mikrobiologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda, woda na pływalniach, woda w kąpielisku, woda w miejscu wykorzystywanym do kąpieli Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL (Colilert - 18) PN-EN ISO 9308-2:2014-06 Woda do spozycia przez ludzi, woda, woda na plywalniach, woda w kapielisku, woda w miejscu wykorzystywanym do kapieli Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL (Colilert - 18) PN-EN ISO 9308-2:2014-06","categories":["water","microbiology"],"row_index":73,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Most probable number of coliform bacteria","search_en":"Water intended for human consumption, water, swimming pool water, bathing water, water at a site used for bathing Most probable number of coliform bacteria MPN method (Colilert - 18) PN-EN ISO 9308-2:2014-06","technique_en":"MPN method (Colilert - 18)","test_object_en":"Water intended for human consumption, water, swimming pool water, bathing water, water at a site used for bathing","methodology_zh":"大肠菌群最可能数（MPN）","search_zh":"生活饮用水、水、游泳池水、浴场水、用于游泳场所的水 大肠菌群最可能数（MPN） PN-EN ISO 9308-2:2014-06","test_object_zh":"生活饮用水、水、游泳池水、浴场水、用于游泳场所的水"},{"_id":"6a8377f3af14b9c0e7b1fb56","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda, woda na pływalniach, woda w kąpielisku, woda w miejscu wykorzystywanym do kąpieli","methodology":"Najbardziej prawdopodobna liczba Escherichia coli","parameters":[],"technique":"Metoda NPL (Colilert - 18)","techniques":["Metoda NPL (Colilert - 18)"],"computed":[],"activity":"Najbardziej prawdopodobna liczba Escherichia coli\nMetoda NPL (Colilert - 18)","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Mikrobiologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda, woda na pływalniach, woda w kąpielisku, woda w miejscu wykorzystywanym do kąpieli Najbardziej prawdopodobna liczba Escherichia coli\nMetoda NPL (Colilert - 18) PN-EN ISO 9308-2:2014-06 Woda do spozycia przez ludzi, woda, woda na plywalniach, woda w kapielisku, woda w miejscu wykorzystywanym do kapieli Najbardziej prawdopodobna liczba Escherichia coli\nMetoda NPL (Colilert - 18) PN-EN ISO 9308-2:2014-06","categories":["water","microbiology"],"row_index":74,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Most probable number of Escherichia coli","search_en":"Water intended for human consumption, water, swimming pool water, bathing water, water at a site used for bathing Most probable number of Escherichia coli MPN method (Colilert - 18) PN-EN ISO 9308-2:2014-06","technique_en":"MPN method (Colilert - 18)","test_object_en":"Water intended for human consumption, water, swimming pool water, bathing water, water at a site used for bathing","search_zh":"生活饮用水、水、游泳池水、浴场水、用于游泳场所的水 大肠埃希氏菌最可能数 PN-EN ISO 9308-2:2014-06","test_object_zh":"生活饮用水、水、游泳池水、浴场水、用于游泳场所的水","methodology_zh":"大肠埃希氏菌最可能数"},{"_id":"6a8377f3af14b9c0e7b1fb57","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda, woda na pływalniach, woda w kąpielisku, woda w miejscu wykorzystywanym do kąpieli","methodology":"Liczba enterokoków kałowych","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba enterokoków kałowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Mikrobiologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda, woda na pływalniach, woda w kąpielisku, woda w miejscu wykorzystywanym do kąpieli Liczba enterokoków kałowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda do spozycia przez ludzi, woda, woda na plywalniach, woda w kapielisku, woda w miejscu wykorzystywanym do kapieli Liczba enterokokow kalowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":75,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Intestinal enterococci count","search_en":"Water intended for human consumption, water, swimming pool water, bathing water, water at a site used for bathing Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption, water, swimming pool water, bathing water, water at a site used for bathing","methodology_zh":"粪肠球菌计数","search_zh":"生活饮用水、水、游泳池水、浴场水、用于游泳场所的水 粪肠球菌计数 膜过滤法 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"生活饮用水、水、游泳池水、浴场水、用于游泳场所的水"},{"_id":"6a8377f3af14b9c0e7b1fb58","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda, woda na pływalniach, woda w kąpielisku, woda w miejscu wykorzystywanym do kąpieli","methodology":"Liczba Pseudomonas aeruginosa","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PN-EN ISO 16266 :2009","norm_bases":["PN-EN ISO 16266 :2009"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Mikrobiologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda, woda na pływalniach, woda w kąpielisku, woda w miejscu wykorzystywanym do kąpieli Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266 :2009 Woda do spozycia przez ludzi, woda, woda na plywalniach, woda w kapielisku, woda w miejscu wykorzystywanym do kapieli Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266 :2009","categories":["water"],"row_index":76,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Pseudomonas aeruginosa count","search_en":"Water intended for human consumption, water, swimming pool water, bathing water, water at a site used for bathing Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266 :2009","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption, water, swimming pool water, bathing water, water at a site used for bathing","methodology_zh":"铜绿假单胞菌计数","search_zh":"生活饮用水、水、游泳池水、浴场水、用于游泳场所的水 铜绿假单胞菌计数 膜过滤法 PN-EN ISO 16266 :2009","technique_zh":"膜过滤法","test_object_zh":"生活饮用水、水、游泳池水、浴场水、用于游泳场所的水"},{"_id":"6a8377f3af14b9c0e7b1fb59","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda, woda na pływalniach, woda w kąpielisku, woda w miejscu wykorzystywanym do kąpieli","methodology":"Liczba gronkowców koagulazododatnich","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba gronkowców koagulazododatnich\nMetoda filtracji membranowej","reference":"NIZP-PZH ZHK: 2007 z wyłączeniem p. 2.3.1 i 2.3.3.1","norm_bases":["NIZP-PZH ZHK: 2007 z wyłączeniem p. 2.3.1 i 2.3.3.1"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Mikrobiologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda, woda na pływalniach, woda w kąpielisku, woda w miejscu wykorzystywanym do kąpieli Liczba gronkowców koagulazododatnich\nMetoda filtracji membranowej NIZP-PZH ZHK: 2007 z wyłączeniem p. 2.3.1 i 2.3.3.1 Woda do spozycia przez ludzi, woda, woda na plywalniach, woda w kapielisku, woda w miejscu wykorzystywanym do kapieli Liczba gronkowcow koagulazododatnich\nMetoda filtracji membranowej NIZP-PZH ZHK: 2007 z wylaczeniem p. 2.3.1 i 2.3.3.1","categories":["water"],"row_index":77,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Coagulase-positive staphylococci count","search_en":"Water intended for human consumption, water, swimming pool water, bathing water, water at a site used for bathing Coagulase-positive staphylococci count Membrane filtration method NIZP-PZH ZHK: 2007 z wyłączeniem p. 2.3.1 i 2.3.3.1","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption, water, swimming pool water, bathing water, water at a site used for bathing","search_zh":"生活饮用水、水、游泳池水、浴场水、用于游泳场所的水 凝固酶阳性葡萄球菌计数 膜过滤法 NIZP-PZH ZHK: 2007 z wyłączeniem p. 2.3.1 i 2.3.3.1","technique_zh":"膜过滤法","methodology_zh":"凝固酶阳性葡萄球菌计数","test_object_zh":"生活饮用水、水、游泳池水、浴场水、用于游泳场所的水"},{"_id":"6a8377f3af14b9c0e7b1fb5a","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda, woda na pływalniach","methodology":"Liczba bakterii z rodzaju Legionella","parameters":[],"technique":"Metoda filtracji membranowej matryca A metoda 5 (pożywka A) metoda 7 (pożywka C-GVPC)","techniques":["Metoda filtracji membranowej matryca A metoda 5 (pożywka A) metoda 7 (pożywka C-GVPC)"],"computed":[],"activity":"Liczba bakterii z rodzaju Legionella\nMetoda filtracji membranowej matryca A metoda 5 (pożywka A) metoda 7 (pożywka C-GVPC)","reference":"PN-EN ISO 11731:2017-08 +Ap1:2019-12","norm_bases":["PN-EN ISO 11731:2017-08 +Ap1:2019-12"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Mikrobiologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda, woda na pływalniach Liczba bakterii z rodzaju Legionella\nMetoda filtracji membranowej matryca A metoda 5 (pożywka A) metoda 7 (pożywka C-GVPC) PN-EN ISO 11731:2017-08 +Ap1:2019-12 Woda do spozycia przez ludzi, woda, woda na plywalniach Liczba bakterii z rodzaju Legionella\nMetoda filtracji membranowej matryca A metoda 5 (pozywka A) metoda 7 (pozywka C-GVPC) PN-EN ISO 11731:2017-08 +Ap1:2019-12","categories":["microbiology","water"],"row_index":78,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Count of bacteria of the genus Legionella","search_en":"Water intended for human consumption, water, swimming pool water Count of bacteria of the genus Legionella Membrane filtration method matrix A method 5 (medium A) method 7 (medium C-GVPC) PN-EN ISO 11731:2017-08 +Ap1:2019-12","technique_en":"Membrane filtration method matrix A method 5 (medium A) method 7 (medium C-GVPC)","test_object_en":"Water intended for human consumption, water, swimming pool water","methodology_zh":"军团菌属细菌计数","search_zh":"生活饮用水、水、游泳池水 军团菌属细菌计数 PN-EN ISO 11731:2017-08 +Ap1:2019-12","test_object_zh":"生活饮用水、水、游泳池水"},{"_id":"6a8377f3af14b9c0e7b1fb5b","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda, woda na pływalniach","methodology":"Identyfikacja bakterii z rodzaju Legionella w kierunku Legionella pneumophila","parameters":[],"technique":"Metoda aglutynacji","techniques":["Metoda aglutynacji"],"computed":[],"activity":"Identyfikacja bakterii z rodzaju Legionella w kierunku Legionella pneumophila\nMetoda aglutynacji","reference":"IN/OL/12 wydanie 3 z dnia 15.04.2022 r.","norm_bases":["IN/OL/12 wydanie 3 z dnia 15.04.2022 r."],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Mikrobiologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda, woda na pływalniach Identyfikacja bakterii z rodzaju Legionella w kierunku Legionella pneumophila\nMetoda aglutynacji IN/OL/12 wydanie 3 z dnia 15.04.2022 r. Woda do spozycia przez ludzi, woda, woda na plywalniach Identyfikacja bakterii z rodzaju Legionella w kierunku Legionella pneumophila\nMetoda aglutynacji IN/OL/12 wydanie 3 z dnia 15.04.2022 r.","categories":["microbiology","water"],"row_index":79,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Water intended for human consumption, water, swimming pool water Agglutination method IN/OL/12 wydanie 3 z dnia 15.04.2022 r.","technique_en":"Agglutination method","test_object_en":"Water intended for human consumption, water, swimming pool water","search_zh":"生活饮用水、水、游泳池水 IN/OL/12 wydanie 3 z dnia 15.04.2022 r.","test_object_zh":"生活饮用水、水、游泳池水"},{"_id":"6a8377f3af14b9c0e7b1fb5c","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Woda źródlana, stołowa lub mineralna","methodology":"Liczba przetrwalników beztlenowców redukujących siarczyny (Clostridia)","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba przetrwalników beztlenowców redukujących siarczyny (Clostridia)\nMetoda filtracji membranowej","reference":"PN-EN 26461-2:2001","norm_bases":["PN-EN 26461-2:2001"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Mikrobiologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda źródlana, stołowa lub mineralna Liczba przetrwalników beztlenowców redukujących siarczyny (Clostridia)\nMetoda filtracji membranowej PN-EN 26461-2:2001 Woda zrodlana, stolowa lub mineralna Liczba przetrwalnikow beztlenowcow redukujacych siarczyny (Clostridia)\nMetoda filtracji membranowej PN-EN 26461-2:2001","categories":["water"],"row_index":80,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Count of spores of sulphite-reducing anaerobes (Clostridia)","search_en":"Spring, table or mineral water Count of spores of sulphite-reducing anaerobes (Clostridia) Membrane filtration method PN-EN 26461-2:2001","technique_en":"Membrane filtration method","test_object_en":"Spring, table or mineral water","search_zh":"亚硫酸盐还原厌氧菌（梭菌属）芽孢数 膜过滤法 PN-EN 26461-2:2001","technique_zh":"膜过滤法","methodology_zh":"亚硫酸盐还原厌氧菌（梭菌属）芽孢数"},{"_id":"6a8377f3af14b9c0e7b1fb5d","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Mięso i przetwory mięsne, Drób i przetwory drobiowe, Jaja i przetwory jajeczne, Ryby i przetwory rybne, Mleko i przetwory mleczne, Przetwory zbożowo-mączne, Wyroby cukiernicze i słodycze, Owoce, warzywa i przetwory warzywno-owocowe oraz warzywno-mięsne, Koncentraty spożywcze, Surowce i przetwory zielarskie, Przyprawy, Wyroby garmażeryjne i kulinarne, Środki spożywcze specjalnego przeznaczenia żywieniowego, Suplementy diety, Żywność mrożona","methodology":"Liczba bakterii z grupy coli","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba bakterii z grupy coli\nMetoda płytkowa (posiew wgłębny)","reference":"PN-ISO 4832:2007","norm_bases":["PN-ISO 4832:2007"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Mikrobiologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i przetwory mięsne, Drób i przetwory drobiowe, Jaja i przetwory jajeczne, Ryby i przetwory rybne, Mleko i przetwory mleczne, Przetwory zbożowo-mączne, Wyroby cukiernicze i słodycze, Owoce, warzywa i przetwory warzywno-owocowe oraz warzywno-mięsne, Koncentraty spożywcze, Surowce i przetwory zielarskie, Przyprawy, Wyroby garmażeryjne i kulinarne, Środki spożywcze specjalnego przeznaczenia żywieniowego, Suplementy diety, Żywność mrożona Liczba bakterii z grupy coli\nMetoda płytkowa (posiew wgłębny) PN-ISO 4832:2007 Mieso i przetwory miesne, Drob i przetwory drobiowe, Jaja i przetwory jajeczne, Ryby i przetwory rybne, Mleko i przetwory mleczne, Przetwory zbozowo-maczne, Wyroby cukiernicze i slodycze, Owoce, warzywa i przetwory warzywno-owocowe oraz warzywno-miesne, Koncentraty spozywcze, Surowce i przetwory zielarskie, Przyprawy, Wyroby garmazeryjne i kulinarne, Srodki spozywcze specjalnego przeznaczenia zywieniowego, Suplementy diety, Zywnosc mrozona Liczba bakterii z grupy coli\nMetoda plytkowa (posiew wglebny) PN-ISO 4832:2007","categories":["food","microbiology","pharma"],"row_index":81,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Coliform bacteria count","search_en":"Meat and meat products, Poultry and poultry products, Eggs and egg products, Fish and fish products, Milk and milk products, Cereal-flour products, Confectionery products and sweets, Fruit, vegetables and vegetable-fruit and vegetable-meat preserves, Food concentrates, Herbal raw materials and preparations, Spices, Delicatessen and culinary products, Foodstuffs for particular nutritional uses, Food supplements, Frozen food Coliform bacteria count Plate method (pour plate) PN-ISO 4832:2007","technique_en":"Plate method (pour plate)","test_object_en":"Meat and meat products, Poultry and poultry products, Eggs and egg products, Fish and fish products, Milk and milk products, Cereal-flour products, Confectionery products and sweets, Fruit, vegetables and vegetable-fruit and vegetable-meat preserves, Food concentrates, Herbal raw materials and preparations, Spices, Delicatessen and culinary products, Foodstuffs for particular nutritional uses, Food supplements, Frozen food","search_zh":"肉与肉制品，禽肉与禽类制品，蛋与蛋制品，鱼与鱼制品，乳与乳制品，谷物粉制品，糖果与甜食，水果、蔬菜与果蔬制品及蔬菜肉类制品，食品浓缩制品，草药原料与制品，香辛料，熟食与烹调制品，特殊营养用途食品，膳食补充剂，冷冻食品 大肠菌群计数 平板法（倾注培养） PN-ISO 4832:2007","technique_zh":"平板法（倾注培养）","methodology_zh":"大肠菌群计数","test_object_zh":"肉与肉制品，禽肉与禽类制品，蛋与蛋制品，鱼与鱼制品，乳与乳制品，谷物粉制品，糖果与甜食，水果、蔬菜与果蔬制品及蔬菜肉类制品，食品浓缩制品，草药原料与制品，香辛料，熟食与烹调制品，特殊营养用途食品，膳食补充剂，冷冻食品"},{"_id":"6a8377f3af14b9c0e7b1fb5e","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Mięso i przetwory mięsne, Drób i przetwory drobiowe, Jaja i przetwory jajeczne, Ryby i przetwory rybne, Mleko i przetwory mleczne, Przetwory zbożowo-mączne, Wyroby cukiernicze i słodycze, Owoce, warzywa i przetwory warzywno-owocowe oraz warzywno-mięsne, Koncentraty spożywcze, Surowce i przetwory zielarskie, Przyprawy, Wyroby garmażeryjne i kulinarne, Środki spożywcze specjalnego przeznaczenia żywieniowego, Suplementy diety, Żywność mrożona","methodology":"Obecność Listeria monocytogenes","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność Listeria monocytogenes\nMetoda hodowlana z potwierdzeniem biochemicznym","reference":"PN-EN ISO 11290-1:2017-07","norm_bases":["PN-EN ISO 11290-1:2017-07"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Mikrobiologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i przetwory mięsne, Drób i przetwory drobiowe, Jaja i przetwory jajeczne, Ryby i przetwory rybne, Mleko i przetwory mleczne, Przetwory zbożowo-mączne, Wyroby cukiernicze i słodycze, Owoce, warzywa i przetwory warzywno-owocowe oraz warzywno-mięsne, Koncentraty spożywcze, Surowce i przetwory zielarskie, Przyprawy, Wyroby garmażeryjne i kulinarne, Środki spożywcze specjalnego przeznaczenia żywieniowego, Suplementy diety, Żywność mrożona Obecność Listeria monocytogenes\nMetoda hodowlana z potwierdzeniem biochemicznym PN-EN ISO 11290-1:2017-07 Mieso i przetwory miesne, Drob i przetwory drobiowe, Jaja i przetwory jajeczne, Ryby i przetwory rybne, Mleko i przetwory mleczne, Przetwory zbozowo-maczne, Wyroby cukiernicze i slodycze, Owoce, warzywa i przetwory warzywno-owocowe oraz warzywno-miesne, Koncentraty spozywcze, Surowce i przetwory zielarskie, Przyprawy, Wyroby garmazeryjne i kulinarne, Srodki spozywcze specjalnego przeznaczenia zywieniowego, Suplementy diety, Zywnosc mrozona Obecnosc Listeria monocytogenes\nMetoda hodowlana z potwierdzeniem biochemicznym PN-EN ISO 11290-1:2017-07","categories":["food","microbiology","pharma"],"row_index":82,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of Listeria monocytogenes","search_en":"Meat and meat products, Poultry and poultry products, Eggs and egg products, Fish and fish products, Milk and milk products, Cereal-flour products, Confectionery products and sweets, Fruit, vegetables and vegetable-fruit and vegetable-meat preserves, Food concentrates, Herbal raw materials and preparations, Spices, Delicatessen and culinary products, Foodstuffs for particular nutritional uses, Food supplements, Frozen food Presence of Listeria monocytogenes Culture method with biochemical confirmation PN-EN ISO 11290-1:2017-07","technique_en":"Culture method with biochemical confirmation","test_object_en":"Meat and meat products, Poultry and poultry products, Eggs and egg products, Fish and fish products, Milk and milk products, Cereal-flour products, Confectionery products and sweets, Fruit, vegetables and vegetable-fruit and vegetable-meat preserves, Food concentrates, Herbal raw materials and preparations, Spices, Delicatessen and culinary products, Foodstuffs for particular nutritional uses, Food supplements, Frozen food","search_zh":"肉与肉制品，禽肉与禽类制品，蛋与蛋制品，鱼与鱼制品，乳与乳制品，谷物粉制品，糖果与甜食，水果、蔬菜与果蔬制品及蔬菜肉类制品，食品浓缩制品，草药原料与制品，香辛料，熟食与烹调制品，特殊营养用途食品，膳食补充剂，冷冻食品 单核细胞增生李斯特氏菌的检出 培养法结合生化确认 PN-EN ISO 11290-1:2017-07","technique_zh":"培养法结合生化确认","methodology_zh":"单核细胞增生李斯特氏菌的检出","test_object_zh":"肉与肉制品，禽肉与禽类制品，蛋与蛋制品，鱼与鱼制品，乳与乳制品，谷物粉制品，糖果与甜食，水果、蔬菜与果蔬制品及蔬菜肉类制品，食品浓缩制品，草药原料与制品，香辛料，熟食与烹调制品，特殊营养用途食品，膳食补充剂，冷冻食品"},{"_id":"6a8377f3af14b9c0e7b1fb5f","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Mięso i przetwory mięsne, Drób i przetwory drobiowe, Jaja i przetwory jajeczne, Ryby i przetwory rybne, Mleko i przetwory mleczne, Przetwory zbożowo-mączne, Wyroby cukiernicze i słodycze, Owoce, warzywa i przetwory warzywno-owocowe oraz warzywno-mięsne, Koncentraty spożywcze, Surowce i przetwory zielarskie, Przyprawy, Wyroby garmażeryjne i kulinarne, Środki spożywcze specjalnego przeznaczenia żywieniowego, Suplementy diety, Żywność mrożona","methodology":"Liczba Enterobacteriaceae","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba Enterobacteriaceae\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 21528-2:2017-08","norm_bases":["PN-EN ISO 21528-2:2017-08"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Mikrobiologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i przetwory mięsne, Drób i przetwory drobiowe, Jaja i przetwory jajeczne, Ryby i przetwory rybne, Mleko i przetwory mleczne, Przetwory zbożowo-mączne, Wyroby cukiernicze i słodycze, Owoce, warzywa i przetwory warzywno-owocowe oraz warzywno-mięsne, Koncentraty spożywcze, Surowce i przetwory zielarskie, Przyprawy, Wyroby garmażeryjne i kulinarne, Środki spożywcze specjalnego przeznaczenia żywieniowego, Suplementy diety, Żywność mrożona Liczba Enterobacteriaceae\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 21528-2:2017-08 Mieso i przetwory miesne, Drob i przetwory drobiowe, Jaja i przetwory jajeczne, Ryby i przetwory rybne, Mleko i przetwory mleczne, Przetwory zbozowo-maczne, Wyroby cukiernicze i slodycze, Owoce, warzywa i przetwory warzywno-owocowe oraz warzywno-miesne, Koncentraty spozywcze, Surowce i przetwory zielarskie, Przyprawy, Wyroby garmazeryjne i kulinarne, Srodki spozywcze specjalnego przeznaczenia zywieniowego, Suplementy diety, Zywnosc mrozona Liczba Enterobacteriaceae\nMetoda plytkowa (posiew wglebny) PN-EN ISO 21528-2:2017-08","categories":["food","pharma"],"row_index":83,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Enterobacteriaceae count","search_en":"Meat and meat products, Poultry and poultry products, Eggs and egg products, Fish and fish products, Milk and milk products, Cereal-flour products, Confectionery products and sweets, Fruit, vegetables and vegetable-fruit and vegetable-meat preserves, Food concentrates, Herbal raw materials and preparations, Spices, Delicatessen and culinary products, Foodstuffs for particular nutritional uses, Food supplements, Frozen food Enterobacteriaceae count Plate method (pour plate) PN-EN ISO 21528-2:2017-08","technique_en":"Plate method (pour plate)","test_object_en":"Meat and meat products, Poultry and poultry products, Eggs and egg products, Fish and fish products, Milk and milk products, Cereal-flour products, Confectionery products and sweets, Fruit, vegetables and vegetable-fruit and vegetable-meat preserves, Food concentrates, Herbal raw materials and preparations, Spices, Delicatessen and culinary products, Foodstuffs for particular nutritional uses, Food supplements, Frozen food","methodology_zh":"肠杆菌科（Enterobacteriaceae）计数","search_zh":"肉与肉制品，禽肉与禽类制品，蛋与蛋制品，鱼与鱼制品，乳与乳制品，谷物粉制品，糖果与甜食，水果、蔬菜与果蔬制品及蔬菜肉类制品，食品浓缩制品，草药原料与制品，香辛料，熟食与烹调制品，特殊营养用途食品，膳食补充剂，冷冻食品 肠杆菌科（Enterobacteriaceae）计数 平板法（倾注培养） PN-EN ISO 21528-2:2017-08","technique_zh":"平板法（倾注培养）","test_object_zh":"肉与肉制品，禽肉与禽类制品，蛋与蛋制品，鱼与鱼制品，乳与乳制品，谷物粉制品，糖果与甜食，水果、蔬菜与果蔬制品及蔬菜肉类制品，食品浓缩制品，草药原料与制品，香辛料，熟食与烹调制品，特殊营养用途食品，膳食补充剂，冷冻食品"},{"_id":"6a8377f3af14b9c0e7b1fb60","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Mięso i przetwory mięsne, Drób i przetwory drobiowe, Jaja i przetwory jajeczne, Ryby i przetwory rybne, Mleko i przetwory mleczne, Przetwory zbożowo-mączne, Wyroby cukiernicze i słodycze, Owoce, warzywa i przetwory warzywno-owocowe oraz warzywno-mięsne, Koncentraty spożywcze, Surowce i przetwory zielarskie, Przyprawy, Wyroby garmażeryjne i kulinarne, Środki spożywcze specjalnego przeznaczenia żywieniowego, Suplementy diety, Żywność mrożona","methodology":"Obecność Enterobacteriaceae","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność Enterobacteriaceae\nMetoda hodowlana z potwierdzeniem biochemicznym","reference":"PN-EN ISO 21528-1:2017-08","norm_bases":["PN-EN ISO 21528-1:2017-08"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Mikrobiologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i przetwory mięsne, Drób i przetwory drobiowe, Jaja i przetwory jajeczne, Ryby i przetwory rybne, Mleko i przetwory mleczne, Przetwory zbożowo-mączne, Wyroby cukiernicze i słodycze, Owoce, warzywa i przetwory warzywno-owocowe oraz warzywno-mięsne, Koncentraty spożywcze, Surowce i przetwory zielarskie, Przyprawy, Wyroby garmażeryjne i kulinarne, Środki spożywcze specjalnego przeznaczenia żywieniowego, Suplementy diety, Żywność mrożona Obecność Enterobacteriaceae\nMetoda hodowlana z potwierdzeniem biochemicznym PN-EN ISO 21528-1:2017-08 Mieso i przetwory miesne, Drob i przetwory drobiowe, Jaja i przetwory jajeczne, Ryby i przetwory rybne, Mleko i przetwory mleczne, Przetwory zbozowo-maczne, Wyroby cukiernicze i slodycze, Owoce, warzywa i przetwory warzywno-owocowe oraz warzywno-miesne, Koncentraty spozywcze, Surowce i przetwory zielarskie, Przyprawy, Wyroby garmazeryjne i kulinarne, Srodki spozywcze specjalnego przeznaczenia zywieniowego, Suplementy diety, Zywnosc mrozona Obecnosc Enterobacteriaceae\nMetoda hodowlana z potwierdzeniem biochemicznym PN-EN ISO 21528-1:2017-08","categories":["food","pharma"],"row_index":84,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of Enterobacteriaceae","search_en":"Meat and meat products, Poultry and poultry products, Eggs and egg products, Fish and fish products, Milk and milk products, Cereal-flour products, Confectionery products and sweets, Fruit, vegetables and vegetable-fruit and vegetable-meat preserves, Food concentrates, Herbal raw materials and preparations, Spices, Delicatessen and culinary products, Foodstuffs for particular nutritional uses, Food supplements, Frozen food Presence of Enterobacteriaceae Culture method with biochemical confirmation PN-EN ISO 21528-1:2017-08","technique_en":"Culture method with biochemical confirmation","test_object_en":"Meat and meat products, Poultry and poultry products, Eggs and egg products, Fish and fish products, Milk and milk products, Cereal-flour products, Confectionery products and sweets, Fruit, vegetables and vegetable-fruit and vegetable-meat preserves, Food concentrates, Herbal raw materials and preparations, Spices, Delicatessen and culinary products, Foodstuffs for particular nutritional uses, Food supplements, Frozen food","search_zh":"肉与肉制品，禽肉与禽类制品，蛋与蛋制品，鱼与鱼制品，乳与乳制品，谷物粉制品，糖果与甜食，水果、蔬菜与果蔬制品及蔬菜肉类制品，食品浓缩制品，草药原料与制品，香辛料，熟食与烹调制品，特殊营养用途食品，膳食补充剂，冷冻食品 肠杆菌科的检出 培养法结合生化确认 PN-EN ISO 21528-1:2017-08","technique_zh":"培养法结合生化确认","methodology_zh":"肠杆菌科的检出","test_object_zh":"肉与肉制品，禽肉与禽类制品，蛋与蛋制品，鱼与鱼制品，乳与乳制品，谷物粉制品，糖果与甜食，水果、蔬菜与果蔬制品及蔬菜肉类制品，食品浓缩制品，草药原料与制品，香辛料，熟食与烹调制品，特殊营养用途食品，膳食补充剂，冷冻食品"},{"_id":"6a8377f3af14b9c0e7b1fb61","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Mięso i przetwory mięsne, Drób i przetwory drobiowe, Jaja i przetwory jajeczne, Ryby i przetwory rybne, Mleko i przetwory mleczne, Przetwory zbożowo-mączne, Wyroby cukiernicze i słodycze, Owoce, warzywa i przetwory warzywno-owocowe oraz warzywno-mięsne, Koncentraty spożywcze, Surowce i przetwory zielarskie, Przyprawy, Wyroby garmażeryjne i kulinarne, Środki spożywcze specjalnego przeznaczenia żywieniowego, Suplementy diety, Żywność mrożona","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 4833-1:2013-12 +Ap1:2016-11+A1:2022-06","norm_bases":["PN-EN ISO 4833-1:2013-12 +Ap1:2016-11+A1:2022-06"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Mikrobiologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i przetwory mięsne, Drób i przetwory drobiowe, Jaja i przetwory jajeczne, Ryby i przetwory rybne, Mleko i przetwory mleczne, Przetwory zbożowo-mączne, Wyroby cukiernicze i słodycze, Owoce, warzywa i przetwory warzywno-owocowe oraz warzywno-mięsne, Koncentraty spożywcze, Surowce i przetwory zielarskie, Przyprawy, Wyroby garmażeryjne i kulinarne, Środki spożywcze specjalnego przeznaczenia żywieniowego, Suplementy diety, Żywność mrożona Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 4833-1:2013-12 +Ap1:2016-11+A1:2022-06 Mieso i przetwory miesne, Drob i przetwory drobiowe, Jaja i przetwory jajeczne, Ryby i przetwory rybne, Mleko i przetwory mleczne, Przetwory zbozowo-maczne, Wyroby cukiernicze i slodycze, Owoce, warzywa i przetwory warzywno-owocowe oraz warzywno-miesne, Koncentraty spozywcze, Surowce i przetwory zielarskie, Przyprawy, Wyroby garmazeryjne i kulinarne, Srodki spozywcze specjalnego przeznaczenia zywieniowego, Suplementy diety, Zywnosc mrozona Liczba drobnoustrojow\nMetoda plytkowa (posiew wglebny) PN-EN ISO 4833-1:2013-12 +Ap1:2016-11+A1:2022-06","categories":["food","microbiology","pharma"],"row_index":85,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Microorganism count","search_en":"Meat and meat products, Poultry and poultry products, Eggs and egg products, Fish and fish products, Milk and milk products, Cereal-flour products, Confectionery products and sweets, Fruit, vegetables and vegetable-fruit and vegetable-meat preserves, Food concentrates, Herbal raw materials and preparations, Spices, Delicatessen and culinary products, Foodstuffs for particular nutritional uses, Food supplements, Frozen food Microorganism count Plate method (pour plate) PN-EN ISO 4833-1:2013-12 +Ap1:2016-11+A1:2022-06","technique_en":"Plate method (pour plate)","test_object_en":"Meat and meat products, Poultry and poultry products, Eggs and egg products, Fish and fish products, Milk and milk products, Cereal-flour products, Confectionery products and sweets, Fruit, vegetables and vegetable-fruit and vegetable-meat preserves, Food concentrates, Herbal raw materials and preparations, Spices, Delicatessen and culinary products, Foodstuffs for particular nutritional uses, Food supplements, Frozen food","methodology_zh":"菌落总数","search_zh":"肉与肉制品，禽肉与禽类制品，蛋与蛋制品，鱼与鱼制品，乳与乳制品，谷物粉制品，糖果与甜食，水果、蔬菜与果蔬制品及蔬菜肉类制品，食品浓缩制品，草药原料与制品，香辛料，熟食与烹调制品，特殊营养用途食品，膳食补充剂，冷冻食品 菌落总数 平板法（倾注培养） PN-EN ISO 4833-1:2013-12 +Ap1:2016-11+A1:2022-06","technique_zh":"平板法（倾注培养）","test_object_zh":"肉与肉制品，禽肉与禽类制品，蛋与蛋制品，鱼与鱼制品，乳与乳制品，谷物粉制品，糖果与甜食，水果、蔬菜与果蔬制品及蔬菜肉类制品，食品浓缩制品，草药原料与制品，香辛料，熟食与烹调制品，特殊营养用途食品，膳食补充剂，冷冻食品"},{"_id":"6a8377f3af14b9c0e7b1fb62","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Mięso i przetwory mięsne, Drób i przetwory drobiowe, Jaja i przetwory jajeczne, Ryby i przetwory rybne, Mleko i przetwory mleczne, Przetwory zbożowo-mączne, Wyroby cukiernicze i słodycze, Owoce, warzywa i przetwory warzywno-owocowe oraz warzywno-mięsne, Koncentraty spożywcze, Surowce i przetwory zielarskie, Przyprawy, Wyroby garmażeryjne i kulinarne, Środki spożywcze specjalnego przeznaczenia żywieniowego, Suplementy diety, Żywność mrożona","methodology":"Liczba gronkowców koagulazododatnich (Staphylococcus aureus i innych gatunków)","parameters":[],"technique":"Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda płytkowa (posiew powierzchniowy)"],"computed":[],"activity":"Liczba gronkowców koagulazododatnich (Staphylococcus aureus i innych gatunków)\nMetoda płytkowa (posiew powierzchniowy)","reference":"PN-EN ISO 6888-1:2022-03 +A1:2024-02","norm_bases":["PN-EN ISO 6888-1:2022-03 +A1:2024-02"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Mikrobiologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i przetwory mięsne, Drób i przetwory drobiowe, Jaja i przetwory jajeczne, Ryby i przetwory rybne, Mleko i przetwory mleczne, Przetwory zbożowo-mączne, Wyroby cukiernicze i słodycze, Owoce, warzywa i przetwory warzywno-owocowe oraz warzywno-mięsne, Koncentraty spożywcze, Surowce i przetwory zielarskie, Przyprawy, Wyroby garmażeryjne i kulinarne, Środki spożywcze specjalnego przeznaczenia żywieniowego, Suplementy diety, Żywność mrożona Liczba gronkowców koagulazododatnich (Staphylococcus aureus i innych gatunków)\nMetoda płytkowa (posiew powierzchniowy) PN-EN ISO 6888-1:2022-03 +A1:2024-02 Mieso i przetwory miesne, Drob i przetwory drobiowe, Jaja i przetwory jajeczne, Ryby i przetwory rybne, Mleko i przetwory mleczne, Przetwory zbozowo-maczne, Wyroby cukiernicze i slodycze, Owoce, warzywa i przetwory warzywno-owocowe oraz warzywno-miesne, Koncentraty spozywcze, Surowce i przetwory zielarskie, Przyprawy, Wyroby garmazeryjne i kulinarne, Srodki spozywcze specjalnego przeznaczenia zywieniowego, Suplementy diety, Zywnosc mrozona Liczba gronkowcow koagulazododatnich (Staphylococcus aureus i innych gatunkow)\nMetoda plytkowa (posiew powierzchniowy) PN-EN ISO 6888-1:2022-03 +A1:2024-02","categories":["food","pharma"],"row_index":86,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Coagulase-positive staphylococci count (Staphylococcus aureus and other species)","search_en":"Meat and meat products, Poultry and poultry products, Eggs and egg products, Fish and fish products, Milk and milk products, Cereal-flour products, Confectionery products and sweets, Fruit, vegetables and vegetable-fruit and vegetable-meat preserves, Food concentrates, Herbal raw materials and preparations, Spices, Delicatessen and culinary products, Foodstuffs for particular nutritional uses, Food supplements, Frozen food Coagulase-positive staphylococci count (Staphylococcus aureus and other species) Plate method (spread plate) PN-EN ISO 6888-1:2022-03 +A1:2024-02","technique_en":"Plate method (spread plate)","test_object_en":"Meat and meat products, Poultry and poultry products, Eggs and egg products, Fish and fish products, Milk and milk products, Cereal-flour products, Confectionery products and sweets, Fruit, vegetables and vegetable-fruit and vegetable-meat preserves, Food concentrates, Herbal raw materials and preparations, Spices, Delicatessen and culinary products, Foodstuffs for particular nutritional uses, Food supplements, Frozen food","search_zh":"肉与肉制品，禽肉与禽类制品，蛋与蛋制品，鱼与鱼制品，乳与乳制品，谷物粉制品，糖果与甜食，水果、蔬菜与果蔬制品及蔬菜肉类制品，食品浓缩制品，草药原料与制品，香辛料，熟食与烹调制品，特殊营养用途食品，膳食补充剂，冷冻食品 凝固酶阳性葡萄球菌计数（金黄色葡萄球菌及其他菌种） 平板法（表面涂布） PN-EN ISO 6888-1:2022-03 +A1:2024-02","technique_zh":"平板法（表面涂布）","methodology_zh":"凝固酶阳性葡萄球菌计数（金黄色葡萄球菌及其他菌种）","test_object_zh":"肉与肉制品，禽肉与禽类制品，蛋与蛋制品，鱼与鱼制品，乳与乳制品，谷物粉制品，糖果与甜食，水果、蔬菜与果蔬制品及蔬菜肉类制品，食品浓缩制品，草药原料与制品，香辛料，熟食与烹调制品，特殊营养用途食品，膳食补充剂，冷冻食品"},{"_id":"6a8377f3af14b9c0e7b1fb63","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Mięso i przetwory mięsne, Drób i przetwory drobiowe, Jaja i przetwory jajeczne, Ryby i przetwory rybne, Mleko i przetwory mleczne, Przetwory zbożowo-mączne, Wyroby cukiernicze i słodycze, Owoce, warzywa i przetwory warzywno-owocowe oraz warzywno-mięsne, Koncentraty spożywcze, Surowce i przetwory zielarskie, Przyprawy, Wyroby garmażeryjne i kulinarne, Środki spożywcze specjalnego przeznaczenia żywieniowego, Suplementy diety, Żywność mrożona","methodology":"Liczba Escherichia coli β-glukuronidazododatnich","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba Escherichia coli β-glukuronidazododatnich\nMetoda płytkowa (posiew wgłębny)","reference":"PN-ISO 16649-2:2004","norm_bases":["PN-ISO 16649-2:2004"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Mikrobiologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i przetwory mięsne, Drób i przetwory drobiowe, Jaja i przetwory jajeczne, Ryby i przetwory rybne, Mleko i przetwory mleczne, Przetwory zbożowo-mączne, Wyroby cukiernicze i słodycze, Owoce, warzywa i przetwory warzywno-owocowe oraz warzywno-mięsne, Koncentraty spożywcze, Surowce i przetwory zielarskie, Przyprawy, Wyroby garmażeryjne i kulinarne, Środki spożywcze specjalnego przeznaczenia żywieniowego, Suplementy diety, Żywność mrożona Liczba Escherichia coli β-glukuronidazododatnich\nMetoda płytkowa (posiew wgłębny) PN-ISO 16649-2:2004 Mieso i przetwory miesne, Drob i przetwory drobiowe, Jaja i przetwory jajeczne, Ryby i przetwory rybne, Mleko i przetwory mleczne, Przetwory zbozowo-maczne, Wyroby cukiernicze i slodycze, Owoce, warzywa i przetwory warzywno-owocowe oraz warzywno-miesne, Koncentraty spozywcze, Surowce i przetwory zielarskie, Przyprawy, Wyroby garmazeryjne i kulinarne, Srodki spozywcze specjalnego przeznaczenia zywieniowego, Suplementy diety, Zywnosc mrozona Liczba Escherichia coli β-glukuronidazododatnich\nMetoda plytkowa (posiew wglebny) PN-ISO 16649-2:2004","categories":["food","microbiology","pharma"],"row_index":87,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Count of β-glucuronidase-positive Escherichia coli","search_en":"Meat and meat products, Poultry and poultry products, Eggs and egg products, Fish and fish products, Milk and milk products, Cereal-flour products, Confectionery products and sweets, Fruit, vegetables and vegetable-fruit and vegetable-meat preserves, Food concentrates, Herbal raw materials and preparations, Spices, Delicatessen and culinary products, Foodstuffs for particular nutritional uses, Food supplements, Frozen food Count of β-glucuronidase-positive Escherichia coli Plate method (pour plate) PN-ISO 16649-2:2004","technique_en":"Plate method (pour plate)","test_object_en":"Meat and meat products, Poultry and poultry products, Eggs and egg products, Fish and fish products, Milk and milk products, Cereal-flour products, Confectionery products and sweets, Fruit, vegetables and vegetable-fruit and vegetable-meat preserves, Food concentrates, Herbal raw materials and preparations, Spices, Delicatessen and culinary products, Foodstuffs for particular nutritional uses, Food supplements, Frozen food","search_zh":"肉与肉制品，禽肉与禽类制品，蛋与蛋制品，鱼与鱼制品，乳与乳制品，谷物粉制品，糖果与甜食，水果、蔬菜与果蔬制品及蔬菜肉类制品，食品浓缩制品，草药原料与制品，香辛料，熟食与烹调制品，特殊营养用途食品，膳食补充剂，冷冻食品 平板法（倾注培养） PN-ISO 16649-2:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"肉与肉制品，禽肉与禽类制品，蛋与蛋制品，鱼与鱼制品，乳与乳制品，谷物粉制品，糖果与甜食，水果、蔬菜与果蔬制品及蔬菜肉类制品，食品浓缩制品，草药原料与制品，香辛料，熟食与烹调制品，特殊营养用途食品，膳食补充剂，冷冻食品"},{"_id":"6a8377f3af14b9c0e7b1fb64","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Mięso i przetwory mięsne, Drób i przetwory drobiowe, Jaja i przetwory jajeczne, Ryby i przetwory rybne, Mleko i przetwory mleczne, Przetwory zbożowo-mączne, Wyroby cukiernicze i słodycze, Owoce, warzywa i przetwory warzywno-owocowe oraz warzywno-mięsne, Koncentraty spożywcze, Surowce i przetwory zielarskie, Przyprawy, Wyroby garmażeryjne i kulinarne, Środki spożywcze specjalnego przeznaczenia żywieniowego, Suplementy diety, Żywność mrożona, Substytuty mięsa, Substytuty nabiału","methodology":"Liczba Listeria monocytogenes","parameters":[],"technique":"Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda płytkowa (posiew powierzchniowy)"],"computed":[],"activity":"Liczba Listeria monocytogenes\nMetoda płytkowa (posiew powierzchniowy)","reference":"PN-EN ISO 11290-2:2017-07","norm_bases":["PN-EN ISO 11290-2:2017-07"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Mikrobiologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i przetwory mięsne, Drób i przetwory drobiowe, Jaja i przetwory jajeczne, Ryby i przetwory rybne, Mleko i przetwory mleczne, Przetwory zbożowo-mączne, Wyroby cukiernicze i słodycze, Owoce, warzywa i przetwory warzywno-owocowe oraz warzywno-mięsne, Koncentraty spożywcze, Surowce i przetwory zielarskie, Przyprawy, Wyroby garmażeryjne i kulinarne, Środki spożywcze specjalnego przeznaczenia żywieniowego, Suplementy diety, Żywność mrożona, Substytuty mięsa, Substytuty nabiału Liczba Listeria monocytogenes\nMetoda płytkowa (posiew powierzchniowy) PN-EN ISO 11290-2:2017-07 Mieso i przetwory miesne, Drob i przetwory drobiowe, Jaja i przetwory jajeczne, Ryby i przetwory rybne, Mleko i przetwory mleczne, Przetwory zbozowo-maczne, Wyroby cukiernicze i slodycze, Owoce, warzywa i przetwory warzywno-owocowe oraz warzywno-miesne, Koncentraty spozywcze, Surowce i przetwory zielarskie, Przyprawy, Wyroby garmazeryjne i kulinarne, Srodki spozywcze specjalnego przeznaczenia zywieniowego, Suplementy diety, Zywnosc mrozona, Substytuty miesa, Substytuty nabialu Liczba Listeria monocytogenes\nMetoda plytkowa (posiew powierzchniowy) PN-EN ISO 11290-2:2017-07","categories":["food","microbiology","pharma"],"row_index":88,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Listeria monocytogenes count","search_en":"Listeria monocytogenes count Plate method (spread plate) PN-EN ISO 11290-2:2017-07","technique_en":"Plate method (spread plate)","search_zh":"单核细胞增生李斯特氏菌计数 平板法（表面涂布） PN-EN ISO 11290-2:2017-07","technique_zh":"平板法（表面涂布）","methodology_zh":"单核细胞增生李斯特氏菌计数"},{"_id":"6a8377f3af14b9c0e7b1fb65","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Mleko i przetwory mleczne","methodology":"Liczba gronkowców koagulazododatnich (Staphylococcus aureus i innych gatunków)","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba gronkowców koagulazododatnich (Staphylococcus aureus i innych gatunków)\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6888-2:2022-03 +A1:2024-02","norm_bases":["PN-EN ISO 6888-2:2022-03 +A1:2024-02"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Mikrobiologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mleko i przetwory mleczne Liczba gronkowców koagulazododatnich (Staphylococcus aureus i innych gatunków)\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6888-2:2022-03 +A1:2024-02 Mleko i przetwory mleczne Liczba gronkowcow koagulazododatnich (Staphylococcus aureus i innych gatunkow)\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6888-2:2022-03 +A1:2024-02","categories":["food"],"row_index":89,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Coagulase-positive staphylococci count (Staphylococcus aureus and other species)","search_en":"Milk and milk products Coagulase-positive staphylococci count (Staphylococcus aureus and other species) Plate method (pour plate) PN-EN ISO 6888-2:2022-03 +A1:2024-02","technique_en":"Plate method (pour plate)","test_object_en":"Milk and milk products","search_zh":"乳与乳制品 凝固酶阳性葡萄球菌计数（金黄色葡萄球菌及其他菌种） 平板法（倾注培养） PN-EN ISO 6888-2:2022-03 +A1:2024-02","technique_zh":"平板法（倾注培养）","test_object_zh":"乳与乳制品","methodology_zh":"凝固酶阳性葡萄球菌计数（金黄色葡萄球菌及其他菌种）"},{"_id":"6a8377f3af14b9c0e7b1fb66","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Mięso i przetwory mięsne, Drób i przetwory drobiowe, Jaja i przetwory jajeczne, Ryby i przetwory rybne, Mleko i przetwory mleczne, Przetwory zbożowo-mączne, Wyroby cukiernicze i słodycze, Owoce, warzywa i przetwory warzywno-owocowe oraz warzywno-mięsne, Koncentraty spożywcze, Surowce i przetwory zielarskie, Przyprawy, Wyroby garmażeryjne i kulinarne, Środki spożywcze specjalnego przeznaczenia żywieniowego, Suplementy diety, Żywność mrożona, Nasiona oleiste, Substytuty mięsa, Substytuty nabiału","methodology":"Obecność Salmonella spp.","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność Salmonella spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PN-EN ISO 6579-1:2017-04 +A1:2020-09","norm_bases":["PN-EN ISO 6579-1:2017-04 +A1:2020-09"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Mikrobiologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i przetwory mięsne, Drób i przetwory drobiowe, Jaja i przetwory jajeczne, Ryby i przetwory rybne, Mleko i przetwory mleczne, Przetwory zbożowo-mączne, Wyroby cukiernicze i słodycze, Owoce, warzywa i przetwory warzywno-owocowe oraz warzywno-mięsne, Koncentraty spożywcze, Surowce i przetwory zielarskie, Przyprawy, Wyroby garmażeryjne i kulinarne, Środki spożywcze specjalnego przeznaczenia żywieniowego, Suplementy diety, Żywność mrożona, Nasiona oleiste, Substytuty mięsa, Substytuty nabiału Obecność Salmonella spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579-1:2017-04 +A1:2020-09 Mieso i przetwory miesne, Drob i przetwory drobiowe, Jaja i przetwory jajeczne, Ryby i przetwory rybne, Mleko i przetwory mleczne, Przetwory zbozowo-maczne, Wyroby cukiernicze i slodycze, Owoce, warzywa i przetwory warzywno-owocowe oraz warzywno-miesne, Koncentraty spozywcze, Surowce i przetwory zielarskie, Przyprawy, Wyroby garmazeryjne i kulinarne, Srodki spozywcze specjalnego przeznaczenia zywieniowego, Suplementy diety, Zywnosc mrozona, Nasiona oleiste, Substytuty miesa, Substytuty nabialu Obecnosc Salmonella spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579-1:2017-04 +A1:2020-09","categories":["food","microbiology","pharma"],"row_index":90,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of Salmonella spp.","search_en":"Presence of Salmonella spp. Culture method with biochemical and serological confirmation PN-EN ISO 6579-1:2017-04 +A1:2020-09","technique_en":"Culture method with biochemical and serological confirmation","methodology_zh":"沙门氏菌属（Salmonella spp.）的检出","search_zh":"沙门氏菌属（Salmonella spp.）的检出 培养法结合生化与血清学确认 PN-EN ISO 6579-1:2017-04 +A1:2020-09","technique_zh":"培养法结合生化与血清学确认"},{"_id":"6a8377f3af14b9c0e7b1fb67","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Mięso i przetwory mięsne, Drób i przetwory drobiowe, Jaja i przetwory jajeczne, Ryby i przetwory rybne, Mleko i przetwory mleczne, Przetwory zbożowo-mączne, Wyroby cukiernicze i słodycze, Owoce, warzywa i przetwory warzywno-owocowe oraz warzywno-mięsne, Koncentraty spożywcze, Surowce i przetwory zielarskie, Przyprawy, Wyroby garmażeryjne i kulinarne, Środki spożywcze specjalnego przeznaczenia żywieniowego, Suplementy diety, Żywność mrożona, Substytuty mięsa, Substytuty nabiału","methodology":"Liczba przypuszczalnych Bacillus cereus","parameters":[],"technique":"Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda płytkowa (posiew powierzchniowy)"],"computed":[],"activity":"Liczba przypuszczalnych Bacillus cereus\nMetoda płytkowa (posiew powierzchniowy)","reference":"PN-EN ISO 7932:2005 +A1:2020-09 z wył. pkt. 9.5","norm_bases":["PN-EN ISO 7932:2005 +A1:2020-09 z wył. pkt. 9.5"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Mikrobiologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i przetwory mięsne, Drób i przetwory drobiowe, Jaja i przetwory jajeczne, Ryby i przetwory rybne, Mleko i przetwory mleczne, Przetwory zbożowo-mączne, Wyroby cukiernicze i słodycze, Owoce, warzywa i przetwory warzywno-owocowe oraz warzywno-mięsne, Koncentraty spożywcze, Surowce i przetwory zielarskie, Przyprawy, Wyroby garmażeryjne i kulinarne, Środki spożywcze specjalnego przeznaczenia żywieniowego, Suplementy diety, Żywność mrożona, Substytuty mięsa, Substytuty nabiału Liczba przypuszczalnych Bacillus cereus\nMetoda płytkowa (posiew powierzchniowy) PN-EN ISO 7932:2005 +A1:2020-09 z wył. pkt. 9.5 Mieso i przetwory miesne, Drob i przetwory drobiowe, Jaja i przetwory jajeczne, Ryby i przetwory rybne, Mleko i przetwory mleczne, Przetwory zbozowo-maczne, Wyroby cukiernicze i slodycze, Owoce, warzywa i przetwory warzywno-owocowe oraz warzywno-miesne, Koncentraty spozywcze, Surowce i przetwory zielarskie, Przyprawy, Wyroby garmazeryjne i kulinarne, Srodki spozywcze specjalnego przeznaczenia zywieniowego, Suplementy diety, Zywnosc mrozona, Substytuty miesa, Substytuty nabialu Liczba przypuszczalnych Bacillus cereus\nMetoda plytkowa (posiew powierzchniowy) PN-EN ISO 7932:2005 +A1:2020-09 z wyl. pkt. 9.5","categories":["food","pharma"],"row_index":91,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presumptive Bacillus cereus count","search_en":"Presumptive Bacillus cereus count Plate method (spread plate) PN-EN ISO 7932:2005 +A1:2020-09 z wył. pkt. 9.5","technique_en":"Plate method (spread plate)","search_zh":"蜡样芽孢杆菌推定计数 平板法（表面涂布） PN-EN ISO 7932:2005 +A1:2020-09 z wył. pkt. 9.5","technique_zh":"平板法（表面涂布）","methodology_zh":"蜡样芽孢杆菌推定计数"},{"_id":"6a8377f3af14b9c0e7b1fb68","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Kał, wymaz z odbytu","methodology":"Obecność i identyfikacja pałeczek Salmonella, Shigella","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność i identyfikacja pałeczek Salmonella, Shigella\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PB-23 wydanie 6 z dnia 02.09.2025 r. w oparciu o publikacje metodyczne i instrukcje producentów testów","norm_bases":["PB-23 wydanie 6 z dnia 02.09.2025 r. w oparciu o publikacje metodyczne i instrukcje producentów testów"],"lab_section":"Medyczne Laboratorium Diagnostyczne; Sekcja Diagnostyki Medycznej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kał, wymaz z odbytu Obecność i identyfikacja pałeczek Salmonella, Shigella\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB-23 wydanie 6 z dnia 02.09.2025 r. w oparciu o publikacje metodyczne i instrukcje producentów testów Kal, wymaz z odbytu Obecnosc i identyfikacja paleczek Salmonella, Shigella\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB-23 wydanie 6 z dnia 02.09.2025 r. w oparciu o publikacje metodyczne i instrukcje producentow testow","categories":["microbiology"],"row_index":92,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Faeces, rectal swab Culture method with biochemical and serological confirmation PB-23 wydanie 6 z dnia 02.09.2025 r. w oparciu o publikacje metodyczne i instrukcje producentów testów","technique_en":"Culture method with biochemical and serological confirmation","test_object_en":"Faeces, rectal swab","search_zh":"粪便、肛拭子 培养法结合生化与血清学确认 PB-23 wydanie 6 z dnia 02.09.2025 r. w oparciu o publikacje metodyczne i instrukcje producentów testów","technique_zh":"培养法结合生化与血清学确认","test_object_zh":"粪便、肛拭子"},{"_id":"6a8377f3af14b9c0e7b1fb69","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Szczep bakteryjny","methodology":"Identyfikacja pałeczek Salmonella, Shigella","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Identyfikacja pałeczek Salmonella, Shigella\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PB-23 wydanie 6 z dnia 02.09.2025 r. w oparciu o publikacje metodyczne i instrukcje producentów testów","norm_bases":["PB-23 wydanie 6 z dnia 02.09.2025 r. w oparciu o publikacje metodyczne i instrukcje producentów testów"],"lab_section":"Medyczne Laboratorium Diagnostyczne; Sekcja Diagnostyki Medycznej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Szczep bakteryjny Identyfikacja pałeczek Salmonella, Shigella\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB-23 wydanie 6 z dnia 02.09.2025 r. w oparciu o publikacje metodyczne i instrukcje producentów testów Szczep bakteryjny Identyfikacja paleczek Salmonella, Shigella\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB-23 wydanie 6 z dnia 02.09.2025 r. w oparciu o publikacje metodyczne i instrukcje producentow testow","categories":["microbiology"],"row_index":93,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Identification of Salmonella, Shigella","search_en":"Bacterial strain Identification of Salmonella, Shigella Culture method with biochemical and serological confirmation PB-23 wydanie 6 z dnia 02.09.2025 r. w oparciu o publikacje metodyczne i instrukcje producentów testów","technique_en":"Culture method with biochemical and serological confirmation","test_object_en":"Bacterial strain","search_zh":"菌株 培养法结合生化与血清学确认 PB-23 wydanie 6 z dnia 02.09.2025 r. w oparciu o publikacje metodyczne i instrukcje producentów testów","technique_zh":"培养法结合生化与血清学确认","test_object_zh":"菌株"},{"_id":"6a8377f3af14b9c0e7b1fb6a","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Kał, wymaz z odbytu","methodology":"Obecność i identyfikacja: Escherichia coli O157, Yersinia spp.","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność i identyfikacja: Escherichia coli O157, Yersinia spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PB-03 wydanie 6 z dnia 02.09.2025 r. w oparciu o publikacje metodyczne i instrukcje producentów testów","norm_bases":["PB-03 wydanie 6 z dnia 02.09.2025 r. w oparciu o publikacje metodyczne i instrukcje producentów testów"],"lab_section":"Medyczne Laboratorium Diagnostyczne; Sekcja Diagnostyki Medycznej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kał, wymaz z odbytu Obecność i identyfikacja: Escherichia coli O157, Yersinia spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB-03 wydanie 6 z dnia 02.09.2025 r. w oparciu o publikacje metodyczne i instrukcje producentów testów Kal, wymaz z odbytu Obecnosc i identyfikacja: Escherichia coli O157, Yersinia spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB-03 wydanie 6 z dnia 02.09.2025 r. w oparciu o publikacje metodyczne i instrukcje producentow testow","categories":["microbiology"],"row_index":94,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence and identification: Escherichia coli O157, Yersinia spp.","search_en":"Faeces, rectal swab Presence and identification: Escherichia coli O157, Yersinia spp. Culture method with biochemical and serological confirmation PB-03 wydanie 6 z dnia 02.09.2025 r. w oparciu o publikacje metodyczne i instrukcje producentów testów","technique_en":"Culture method with biochemical and serological confirmation","test_object_en":"Faeces, rectal swab","search_zh":"粪便、肛拭子 培养法结合生化与血清学确认 PB-03 wydanie 6 z dnia 02.09.2025 r. w oparciu o publikacje metodyczne i instrukcje producentów testów","technique_zh":"培养法结合生化与血清学确认","test_object_zh":"粪便、肛拭子"},{"_id":"6a8377f3af14b9c0e7b1fb6b","lab_id":"69ad52a3de79e566650fb344","country":"PL","accr_number":"AB 635","accr_body":"PCA","test_object":"Biologiczne wskaźniki kontroli skuteczności sterylizacji","methodology":"Obecność drobnoustrojów wskaźnikowych: Geobacillus stearothermophilus","parameters":[],"technique":"Metoda hodowlana","techniques":["Metoda hodowlana"],"computed":[],"activity":"Obecność drobnoustrojów wskaźnikowych: Geobacillus stearothermophilus\nMetoda hodowlana","reference":"PB-01 wydanie 6 z dnia 02.09.2025 r. w oparciu o instrukcje producentów testów","norm_bases":["PB-01 wydanie 6 z dnia 02.09.2025 r. w oparciu o instrukcje producentów testów"],"lab_section":"Medyczne Laboratorium Diagnostyczne; Sekcja Diagnostyki Medycznej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Biologiczne wskaźniki kontroli skuteczności sterylizacji Obecność drobnoustrojów wskaźnikowych: Geobacillus stearothermophilus\nMetoda hodowlana PB-01 wydanie 6 z dnia 02.09.2025 r. w oparciu o instrukcje producentów testów Biologiczne wskazniki kontroli skutecznosci sterylizacji Obecnosc drobnoustrojow wskaznikowych: Geobacillus stearothermophilus\nMetoda hodowlana PB-01 wydanie 6 z dnia 02.09.2025 r. w oparciu o instrukcje producentow testow","categories":["microbiology"],"row_index":95,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of indicator microorganisms: Geobacillus stearothermophilus","search_en":"Biological indicators for the control of sterilization efficacy Presence of indicator microorganisms: Geobacillus stearothermophilus Culture method PB-01 wydanie 6 z dnia 02.09.2025 r. w oparciu o instrukcje producentów testów","technique_en":"Culture method","test_object_en":"Biological indicators for the control of sterilization efficacy","search_zh":"灭菌效果监测用生物指示物 培养法 PB-01 wydanie 6 z dnia 02.09.2025 r. w oparciu o instrukcje producentów testów","technique_zh":"培养法","test_object_zh":"灭菌效果监测用生物指示物"}],"has_pdf":true}