{"lab":{"_id":"69ad52a3de79e566650fb33e","accr_number":"AB 631","country":"PL","accr_body":"PCA","address":"W RYBNIKU, ul. Kpt. Leopolda Janiego 1, 44-200 Rybnik","categories":["water","microbiology"],"city":"Rybnik","imported_at":"2026-03-08T10:42:43.265Z","methods_count":36,"name":"POWIATOWA STACJA SANITARNO-EPIDEMIOLOGICZNA","parse_status":"parsed","parse_version":3,"pdf_files":["AB_631.pdf"],"scope_summary":"","search_text":"powiatowa stacja sanitarno-epidemiologiczna w rybniku, ul. kpt. leopolda janiego 1, 44-200 rybnik water pharma electronics other microbiology automotive","status":"active","updated_at":"2026-03-08T14:51:32.041Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:32.041Z","location":{"type":"Point","coordinates":[18.5463,50.0971]},"email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20631,podmiot.html","fields_of_testing":[{"codes":"C/28; C/29","pl":"Badania chemiczne wody, wody do spożycia","en":"Chemical tests of water, drinking water"},{"codes":"K/28; K/29","pl":"Badania mikrobiologiczne wody, wody do spożycia","en":"Microbiological tests of water and drinking water"},{"codes":"N/28; N/29","pl":"Badania właściwości fizycznych wody, wody do spożycia","en":"Tests of physical properties of water, drinking water"}],"issue":{"no":"22","date":"11.07.2025"},"parse_date":"2026-07-20T07:09:45.809Z","parse_source":"script-pdfplumber","map_coord":[50.11054,18.545204],"map_geo":"nominatim-street","has_en":true,"category_counts":{"water":36,"microbiology":8},"category_scores":{"water":29.45,"microbiology":1.45},"has_zh":true},"methods":[{"_id":"6a5dc9b9f1c10c8ce825d9ac","lab_id":"69ad52a3de79e566650fb33e","country":"PL","accr_number":"AB 631","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Barwa","methodology_en":"Colour","parameters":[{"name":"Zakres","range":"(5 – 100) mg/l Pt"}],"parameters_en":[{"name":"Range","range":"(5 – 100) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Barwa\nZakres (5 – 100) mg/l Pt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012 +Ap1:2015-06 Metoda C","norm_bases":["PN-EN ISO 7887:2012 +Ap1:2015-06 Metoda C"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Barwa\nZakres (5 – 100) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 +Ap1:2015-06 Metoda C Woda, Woda do spozycia przez ludzi Barwa\nZakres (5 – 100) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 +Ap1:2015-06 Metoda C","categories":["water"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Colour Spectrophotometric method Range PN-EN ISO 7887:2012 +Ap1:2015-06 Metoda C","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(5 – 100) mg/l Pt"}],"search_zh":"水、生活饮用水 色度 分光光度法 范围 PN-EN ISO 7887:2012 +Ap1:2015-06 Metoda C","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9b9f1c10c8ce825d9ad","lab_id":"69ad52a3de79e566650fb33e","country":"PL","accr_number":"AB 631","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Przewodność elektryczna właściwa","methodology_en":"Electrical conductivity","parameters":[{"name":"Zakres","range":"(100 – 3000) μS/cm"}],"parameters_en":[{"name":"Range","range":"(100 – 3000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"technique_en":"Conductometric method","computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa\nZakres (100 – 3000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Przewodność elektryczna właściwa\nZakres (100 – 3000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, Woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa\nZakres (100 – 3000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Electrical conductivity Conductometric method Range PN-EN 27888:1999","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(100 – 3000) μS/cm"}],"search_zh":"水、生活饮用水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9b9f1c10c8ce825d9ae","lab_id":"69ad52a3de79e566650fb33e","country":"PL","accr_number":"AB 631","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Stężenie jonu amonowego","methodology_en":"Ammonium ion concentration","parameters":[{"name":"Zakres","range":"(0,20 – 2,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,20 – 2,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie jonu amonowego\nZakres (0,20 – 2,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-C-04576-4:1994","norm_bases":["PN-C-04576-4:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie jonu amonowego\nZakres (0,20 – 2,0) mg/l\nMetoda spektrofotometryczna PN-C-04576-4:1994 Woda, Woda do spozycia przez ludzi Stezenie jonu amonowego\nZakres (0,20 – 2,0) mg/l\nMetoda spektrofotometryczna PN-C-04576-4:1994","categories":["water"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Ammonium ion concentration Spectrophotometric method Range PN-C-04576-4:1994","methodology_zh":"铵离子浓度","parameters_zh":[{"name":"范围","range":"(0,20 – 2,0) mg/l"}],"search_zh":"水、生活饮用水 铵离子浓度 分光光度法 范围 PN-C-04576-4:1994","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9b9f1c10c8ce825d9af","lab_id":"69ad52a3de79e566650fb33e","country":"PL","accr_number":"AB 631","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Stężenie azotynów","methodology_en":"Nitrite concentration","parameters":[{"name":"Zakres","range":"(0,0125 – 1,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,0125 – 1,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotynów\nZakres (0,0125 – 1,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie azotynów\nZakres (0,0125 – 1,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, Woda do spozycia przez ludzi Stezenie azotynow\nZakres (0,0125 – 1,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Nitrite concentration Spectrophotometric method Range PN-EN 26777:1999","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,0125 – 1,0) mg/l"}],"search_zh":"水、生活饮用水 亚硝酸盐浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9b9f1c10c8ce825d9b0","lab_id":"69ad52a3de79e566650fb33e","country":"PL","accr_number":"AB 631","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Stężenie manganu","methodology_en":"Manganese concentration","parameters":[{"name":"Zakres","range":"(0,015– 4,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,015– 4,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie manganu\nZakres (0,015– 4,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-92/C-04590/03","norm_bases":["PN-92/C-04590/03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie manganu\nZakres (0,015– 4,0) mg/l\nMetoda spektrofotometryczna PN-92/C-04590/03 Woda, Woda do spozycia przez ludzi Stezenie manganu\nZakres (0,015– 4,0) mg/l\nMetoda spektrofotometryczna PN-92/C-04590/03","categories":["water"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Manganese concentration Spectrophotometric method Range PN-92/C-04590/03","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(0,015– 4,0) mg/l"}],"search_zh":"水、生活饮用水 锰浓度 分光光度法 范围 PN-92/C-04590/03","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9b9f1c10c8ce825d9b1","lab_id":"69ad52a3de79e566650fb33e","country":"PL","accr_number":"AB 631","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Stężenie chlorków","methodology_en":"Chloride concentration","parameters":[{"name":"Zakres","range":"(5 – 400) mg/l"}],"parameters_en":[{"name":"Range","range":"(5 – 400) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie chlorków\nZakres (5 – 400) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie chlorków\nZakres (5 – 400) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda, Woda do spozycia przez ludzi Stezenie chlorkow\nZakres (5 – 400) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Chloride concentration Titrimetric method Range PN-ISO 9297:1994","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5 – 400) mg/l"}],"search_zh":"水、生活饮用水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9b9f1c10c8ce825d9b2","lab_id":"69ad52a3de79e566650fb33e","country":"PL","accr_number":"AB 631","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Stężenie wapnia","methodology_en":"Calcium concentration","parameters":[{"name":"Zakres","range":"(2 – 100) mg/l"}],"parameters_en":[{"name":"Range","range":"(2 – 100) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie wapnia\nZakres (2 – 100) mg/l\nMetoda miareczkowa","reference":"PN-ISO 6058:1999","norm_bases":["PN-ISO 6058:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie wapnia\nZakres (2 – 100) mg/l\nMetoda miareczkowa PN-ISO 6058:1999 Woda, Woda do spozycia przez ludzi Stezenie wapnia\nZakres (2 – 100) mg/l\nMetoda miareczkowa PN-ISO 6058:1999","categories":["water"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Calcium concentration Titrimetric method Range PN-ISO 6058:1999","parameters_zh":[{"name":"范围","range":"(2 – 100) mg/l"}],"search_zh":"水、生活饮用水 钙浓度 滴定法 范围 PN-ISO 6058:1999","technique_zh":"滴定法","test_object_zh":"水、生活饮用水","methodology_zh":"钙浓度"},{"_id":"6a5dc9b9f1c10c8ce825d9b3","lab_id":"69ad52a3de79e566650fb33e","country":"PL","accr_number":"AB 631","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Sumaryczne stężenie wapnia i magnezu (twardość ogólna)","methodology_en":"Total concentration of calcium and magnesium (total hardness)","parameters":[{"name":"Zakres","range":"(5,0 – 500) mg/l CaCO3"}],"parameters_en":[{"name":"Range","range":"(5,0 – 500) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Sumaryczne stężenie wapnia i magnezu (twardość ogólna)\nZakres (5,0 – 500) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Sumaryczne stężenie wapnia i magnezu (twardość ogólna)\nZakres (5,0 – 500) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999 Woda, Woda do spozycia przez ludzi Sumaryczne stezenie wapnia i magnezu (twardosc ogolna)\nZakres (5,0 – 500) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Total concentration of calcium and magnesium (total hardness) Titrimetric method Range PN-ISO 6059:1999","parameters_zh":[{"name":"范围","range":"(5,0 – 500) mg/l CaCO3"}],"search_zh":"水、生活饮用水 钙与镁的总浓度（总硬度） 滴定法 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"水、生活饮用水","methodology_zh":"钙与镁的总浓度（总硬度）"},{"_id":"6a5dc9b9f1c10c8ce825d9b4","lab_id":"69ad52a3de79e566650fb33e","country":"PL","accr_number":"AB 631","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Stężenie magnezu (z obliczeń)","methodology_en":"Magnesium concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie magnezu (z obliczeń)","reference":"PN-C-04554-4:1999","norm_bases":["PN-C-04554-4:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie magnezu (z obliczeń) PN-C-04554-4:1999 Woda, Woda do spozycia przez ludzi Stezenie magnezu (z obliczen) PN-C-04554-4:1999","categories":["water"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Magnesium concentration (calculated) PN-C-04554-4:1999","search_zh":"水、生活饮用水 镁浓度（计算值） PN-C-04554-4:1999","test_object_zh":"水、生活饮用水","methodology_zh":"镁浓度（计算值）"},{"_id":"6a5dc9b9f1c10c8ce825d9b5","lab_id":"69ad52a3de79e566650fb33e","country":"PL","accr_number":"AB 631","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Stężenie chloru wolnego","methodology_en":"Free chlorine concentration","parameters":[{"name":"Zakres","range":"(0,05 – 2,00) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,05 – 2,00) mg/l"}],"technique":"Metoda kolorymetryczna","techniques":["Metoda kolorymetryczna"],"technique_en":"Colorimetric method","computed":[],"computed_en":[],"activity":"Stężenie chloru wolnego\nZakres (0,05 – 2,00) mg/l\nMetoda kolorymetryczna","reference":"Instrukcja nr OL.FHK/IR-27 wyd.3 z dnia 01.04.2020 na podstawie testu Hach LANGE nr 8021","norm_bases":["Instrukcja nr OL.FHK/IR-27 wyd.3 z dnia 01.04.2020 na podstawie testu Hach LANGE nr 8021"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie chloru wolnego\nZakres (0,05 – 2,00) mg/l\nMetoda kolorymetryczna Instrukcja nr OL.FHK/IR-27 wyd.3 z dnia 01.04.2020 na podstawie testu Hach LANGE nr 8021 Woda, Woda do spozycia przez ludzi Stezenie chloru wolnego\nZakres (0,05 – 2,00) mg/l\nMetoda kolorymetryczna Instrukcja nr OL.FHK/IR-27 wyd.3 z dnia 01.04.2020 na podstawie testu Hach LANGE nr 8021","categories":["water"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Free chlorine concentration Colorimetric method Range Instrukcja nr OL.FHK/IR-27 wyd.3 z dnia 01.04.2020 na podstawie testu Hach LANGE nr 8021","methodology_zh":"游离氯浓度","parameters_zh":[{"name":"范围","range":"(0,05 – 2,00) mg/l"}],"search_zh":"水、生活饮用水 游离氯浓度 比色法 范围 Instrukcja nr OL.FHK/IR-27 wyd.3 z dnia 01.04.2020 na podstawie testu Hach LANGE nr 8021","technique_zh":"比色法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9b9f1c10c8ce825d9b6","lab_id":"69ad52a3de79e566650fb33e","country":"PL","accr_number":"AB 631","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi","test_object_en":"Water (including swimming pool water), Water intended for human consumption","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"(4,0 – 10,0)"}],"parameters_en":[{"name":"Range","range":"(4,0 – 10,0)"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres (4,0 – 10,0)\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi pH\nZakres (4,0 – 10,0)\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda (w tym woda na plywalniach), Woda do spozycia przez ludzi pH\nZakres (4,0 – 10,0)\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water (including swimming pool water), Water intended for human consumption pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"(4,0 – 10,0)"}],"search_zh":"水（含游泳池水）、生活饮用水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a5dc9b9f1c10c8ce825d9b7","lab_id":"69ad52a3de79e566650fb33e","country":"PL","accr_number":"AB 631","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi","test_object_en":"Water (including swimming pool water), Water intended for human consumption","methodology":"Mętność","methodology_en":"Turbidity","parameters":[{"name":"Zakres","range":"(0,10 – 100) NTU"}],"parameters_en":[{"name":"Range","range":"(0,10 – 100) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"technique_en":"Nephelometric method","computed":[],"computed_en":[],"activity":"Mętność\nZakres (0,10 – 100) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09 z wyłączeniem pkt. 5.4.","norm_bases":["PN-EN ISO 7027-1:2016-09 z wyłączeniem pkt. 5.4."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi Mętność\nZakres (0,10 – 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 z wyłączeniem pkt. 5.4. Woda (w tym woda na plywalniach), Woda do spozycia przez ludzi Metnosc\nZakres (0,10 – 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 z wylaczeniem pkt. 5.4.","categories":["water"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water (including swimming pool water), Water intended for human consumption Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09 z wyłączeniem pkt. 5.4.","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,10 – 100) NTU"}],"search_zh":"水（含游泳池水）、生活饮用水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09 z wyłączeniem pkt. 5.4.","technique_zh":"浊度法（散射法）","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a5dc9b9f1c10c8ce825d9b8","lab_id":"69ad52a3de79e566650fb33e","country":"PL","accr_number":"AB 631","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi","test_object_en":"Water (including swimming pool water), Water intended for human consumption","methodology":"Stężenie azotanów","methodology_en":"Nitrate concentration","parameters":[{"name":"Zakres","range":"(0,18 – 100) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,18 – 100) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotanów\nZakres (0,18 – 100) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi Stężenie azotanów\nZakres (0,18 – 100) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08 Woda (w tym woda na plywalniach), Woda do spozycia przez ludzi Stezenie azotanow\nZakres (0,18 – 100) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water (including swimming pool water), Water intended for human consumption Nitrate concentration Spectrophotometric method Range PN-82/C-04576/08","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,18 – 100) mg/l"}],"search_zh":"水（含游泳池水）、生活饮用水 硝酸盐浓度 分光光度法 范围 PN-82/C-04576/08","technique_zh":"分光光度法","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a5dc9b9f1c10c8ce825d9b9","lab_id":"69ad52a3de79e566650fb33e","country":"PL","accr_number":"AB 631","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi","test_object_en":"Water (including swimming pool water), Water intended for human consumption","methodology":"Stężenie glinu","methodology_en":"Aluminium concentration","parameters":[{"name":"Zakres","range":"(0,040 – 0,40) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,040 – 0,40) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie glinu\nZakres (0,040 – 0,40) mg/l\nMetoda spektrofotometryczna","reference":"PN-92/C-04605/02","norm_bases":["PN-92/C-04605/02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi Stężenie glinu\nZakres (0,040 – 0,40) mg/l\nMetoda spektrofotometryczna PN-92/C-04605/02 Woda (w tym woda na plywalniach), Woda do spozycia przez ludzi Stezenie glinu\nZakres (0,040 – 0,40) mg/l\nMetoda spektrofotometryczna PN-92/C-04605/02","categories":["water"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water (including swimming pool water), Water intended for human consumption Aluminium concentration Spectrophotometric method Range PN-92/C-04605/02","parameters_zh":[{"name":"范围","range":"(0,040 – 0,40) mg/l"}],"search_zh":"水（含游泳池水）、生活饮用水 铝浓度 分光光度法 范围 PN-92/C-04605/02","technique_zh":"分光光度法","methodology_zh":"铝浓度","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a5dc9b9f1c10c8ce825d9ba","lab_id":"69ad52a3de79e566650fb33e","country":"PL","accr_number":"AB 631","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi","test_object_en":"Water (including swimming pool water), Water intended for human consumption","methodology":"Stężenie żelaza ogólnego","methodology_en":"Total iron concentration","parameters":[{"name":"Zakres","range":"(0,050 – 4,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,050 – 4,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie żelaza ogólnego\nZakres (0,050 – 4,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001+Ap1:2016-06","norm_bases":["PN-ISO 6332:2001+Ap1:2016-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi Stężenie żelaza ogólnego\nZakres (0,050 – 4,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06 Woda (w tym woda na plywalniach), Woda do spozycia przez ludzi Stezenie zelaza ogolnego\nZakres (0,050 – 4,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06","categories":["water"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water (including swimming pool water), Water intended for human consumption Total iron concentration Spectrophotometric method Range PN-ISO 6332:2001+Ap1:2016-06","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(0,050 – 4,0) mg/l"}],"search_zh":"水（含游泳池水）、生活饮用水 总铁浓度 分光光度法 范围 PN-ISO 6332:2001+Ap1:2016-06","technique_zh":"分光光度法","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a5dc9b9f1c10c8ce825d9bb","lab_id":"69ad52a3de79e566650fb33e","country":"PL","accr_number":"AB 631","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi","test_object_en":"Water (including swimming pool water), Water intended for human consumption","methodology":"Indeks nadmanganianowy (utlenialność z KMnO4)","methodology_en":"Permanganate index (oxidisability with KMnO4)","parameters":[{"name":"Zakres","range":"(0,6 – 10,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,6 – 10,0) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Indeks nadmanganianowy (utlenialność z KMnO4)\nZakres (0,6 – 10,0) mg/l\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi Indeks nadmanganianowy (utlenialność z KMnO4)\nZakres (0,6 – 10,0) mg/l\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda (w tym woda na plywalniach), Woda do spozycia przez ludzi Indeks nadmanganianowy (utlenialnosc z KMnO4)\nZakres (0,6 – 10,0) mg/l\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water (including swimming pool water), Water intended for human consumption Permanganate index (oxidisability with KMnO4) Titrimetric method Range PN-EN ISO 8467:2001","parameters_zh":[{"name":"范围","range":"(0,6 – 10,0) mg/l"}],"search_zh":"水（含游泳池水）、生活饮用水 高锰酸盐指数（KMnO4 耗氧量） 滴定法 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"水（含游泳池水）、生活饮用水","methodology_zh":"高锰酸盐指数（KMnO4 耗氧量）"},{"_id":"6a5dc9b9f1c10c8ce825d9bc","lab_id":"69ad52a3de79e566650fb33e","country":"PL","accr_number":"AB 631","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach)","test_object_en":"Water (including swimming pool water)","methodology":"Potencjał utleniająco-redukujący (redox) wzg. Ag/AgCl 3,5 mol/l KCl","methodology_en":"Oxidation-reduction (redox) potential ref. to Ag/AgCl 3,5 mol/l KCl","parameters":[{"name":"Zakres","range":"(200-1000) mV"}],"parameters_en":[{"name":"Range","range":"(200-1000) mV"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"Potencjał utleniająco-redukujący (redox) wzg. Ag/AgCl 3,5 mol/l KCl\nZakres (200-1000) mV\nMetoda potencjometryczna","reference":"Instrukcja nr OL.FHK/IR-28 wyd.2 z dnia 01.04.2020","norm_bases":["Instrukcja nr OL.FHK/IR-28 wyd.2 z dnia 01.04.2020"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach) Potencjał utleniająco-redukujący (redox) wzg. Ag/AgCl 3,5 mol/l KCl\nZakres (200-1000) mV\nMetoda potencjometryczna Instrukcja nr OL.FHK/IR-28 wyd.2 z dnia 01.04.2020 Woda (w tym woda na plywalniach) Potencjal utleniajaco-redukujacy (redox) wzg. Ag/AgCl 3,5 mol/l KCl\nZakres (200-1000) mV\nMetoda potencjometryczna Instrukcja nr OL.FHK/IR-28 wyd.2 z dnia 01.04.2020","categories":["water"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water (including swimming pool water) Oxidation-reduction (redox) potential ref. to Ag/AgCl 3,5 mol/l KCl Potentiometric method Range Instrukcja nr OL.FHK/IR-28 wyd.2 z dnia 01.04.2020","parameters_zh":[{"name":"范围","range":"(200-1000) mV"}],"search_zh":"水（含游泳池水） 电位法 范围 Instrukcja nr OL.FHK/IR-28 wyd.2 z dnia 01.04.2020","technique_zh":"电位法","test_object_zh":"水（含游泳池水）"},{"_id":"6a5dc9b9f1c10c8ce825d9bd","lab_id":"69ad52a3de79e566650fb33e","country":"PL","accr_number":"AB 631","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach)","test_object_en":"Water (including swimming pool water)","methodology":"Stężenie chloru wolnego","methodology_en":"Free chlorine concentration","parameters":[{"name":"Zakres","range":"(0,05-2,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,05-2,0) mg/l"}],"technique":"Metoda kolorymetryczna","techniques":["Metoda kolorymetryczna"],"technique_en":"Colorimetric method","computed":[],"computed_en":[],"activity":"Stężenie chloru wolnego\nZakres (0,05-2,0) mg/l\nMetoda kolorymetryczna","reference":"Instrukcja nr OL.FHK/IR-27 wyd.3 z dnia 01.04.2020 na podstawie testu Hach LANGE nr 8021","norm_bases":["Instrukcja nr OL.FHK/IR-27 wyd.3 z dnia 01.04.2020 na podstawie testu Hach LANGE nr 8021"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach) Stężenie chloru wolnego\nZakres (0,05-2,0) mg/l\nMetoda kolorymetryczna Instrukcja nr OL.FHK/IR-27 wyd.3 z dnia 01.04.2020 na podstawie testu Hach LANGE nr 8021 Woda (w tym woda na plywalniach) Stezenie chloru wolnego\nZakres (0,05-2,0) mg/l\nMetoda kolorymetryczna Instrukcja nr OL.FHK/IR-27 wyd.3 z dnia 01.04.2020 na podstawie testu Hach LANGE nr 8021","categories":["water"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water (including swimming pool water) Free chlorine concentration Colorimetric method Range Instrukcja nr OL.FHK/IR-27 wyd.3 z dnia 01.04.2020 na podstawie testu Hach LANGE nr 8021","methodology_zh":"游离氯浓度","parameters_zh":[{"name":"范围","range":"(0,05-2,0) mg/l"}],"search_zh":"水（含游泳池水） 游离氯浓度 比色法 范围 Instrukcja nr OL.FHK/IR-27 wyd.3 z dnia 01.04.2020 na podstawie testu Hach LANGE nr 8021","technique_zh":"比色法","test_object_zh":"水（含游泳池水）"},{"_id":"6a5dc9b9f1c10c8ce825d9be","lab_id":"69ad52a3de79e566650fb33e","country":"PL","accr_number":"AB 631","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach)","test_object_en":"Water (including swimming pool water)","methodology":"Stężenie chloru całkowitego","methodology_en":"Total chlorine concentration","parameters":[{"name":"Zakres","range":"(0,05-2,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,05-2,0) mg/l"}],"technique":"Metoda kolorymetryczna","techniques":["Metoda kolorymetryczna"],"technique_en":"Colorimetric method","computed":[],"computed_en":[],"activity":"Stężenie chloru całkowitego\nZakres (0,05-2,0) mg/l\nMetoda kolorymetryczna","reference":"Instrukcja nr OL.FHK/IR-27 wyd.3 z dnia 01.04.2020 na podstawie testu Hach LANGE nr 8167","norm_bases":["Instrukcja nr OL.FHK/IR-27 wyd.3 z dnia 01.04.2020 na podstawie testu Hach LANGE nr 8167"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach) Stężenie chloru całkowitego\nZakres (0,05-2,0) mg/l\nMetoda kolorymetryczna Instrukcja nr OL.FHK/IR-27 wyd.3 z dnia 01.04.2020 na podstawie testu Hach LANGE nr 8167 Woda (w tym woda na plywalniach) Stezenie chloru calkowitego\nZakres (0,05-2,0) mg/l\nMetoda kolorymetryczna Instrukcja nr OL.FHK/IR-27 wyd.3 z dnia 01.04.2020 na podstawie testu Hach LANGE nr 8167","categories":["water"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water (including swimming pool water) Total chlorine concentration Colorimetric method Range Instrukcja nr OL.FHK/IR-27 wyd.3 z dnia 01.04.2020 na podstawie testu Hach LANGE nr 8167","parameters_zh":[{"name":"范围","range":"(0,05-2,0) mg/l"}],"search_zh":"水（含游泳池水） 总氯浓度 比色法 范围 Instrukcja nr OL.FHK/IR-27 wyd.3 z dnia 01.04.2020 na podstawie testu Hach LANGE nr 8167","technique_zh":"比色法","test_object_zh":"水（含游泳池水）","methodology_zh":"总氯浓度"},{"_id":"6a5dc9b9f1c10c8ce825d9bf","lab_id":"69ad52a3de79e566650fb33e","country":"PL","accr_number":"AB 631","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach)","test_object_en":"Water (including swimming pool water)","methodology":"Stężenie chloru związanego (z obliczeń)","methodology_en":"Combined chlorine concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chloru związanego (z obliczeń)","reference":"Instrukcja nr OL.FHK/IR-27 wyd.3 z dnia 01.04.2020 pkt 2.4.","norm_bases":["Instrukcja nr OL.FHK/IR-27 wyd.3 z dnia 01.04.2020 pkt 2.4."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach) Stężenie chloru związanego (z obliczeń) Instrukcja nr OL.FHK/IR-27 wyd.3 z dnia 01.04.2020 pkt 2.4. Woda (w tym woda na plywalniach) Stezenie chloru zwiazanego (z obliczen) Instrukcja nr OL.FHK/IR-27 wyd.3 z dnia 01.04.2020 pkt 2.4.","categories":["water"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water (including swimming pool water) Combined chlorine concentration (calculated) Instrukcja nr OL.FHK/IR-27 wyd.3 z dnia 01.04.2020 pkt 2.4.","methodology_zh":"化合氯浓度（计算值）","search_zh":"水（含游泳池水） 化合氯浓度（计算值） Instrukcja nr OL.FHK/IR-27 wyd.3 z dnia 01.04.2020 pkt 2.4.","test_object_zh":"水（含游泳池水）"},{"_id":"6a5dc9b9f1c10c8ce825d9c0","lab_id":"69ad52a3de79e566650fb33e","country":"PL","accr_number":"AB 631","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Liczba bakterii grupy coli","methodology_en":"Coliform bacteria count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-ISO 9308-1:1999","norm_bases":["PN-ISO 9308-1:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-ISO 9308-1:1999 Woda, Woda do spozycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-ISO 9308-1:1999","categories":["water","microbiology"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Coliform bacteria count Membrane filtration method PN-ISO 9308-1:1999","methodology_zh":"大肠菌群计数","search_zh":"水、生活饮用水 大肠菌群计数 膜过滤法 PN-ISO 9308-1:1999","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9b9f1c10c8ce825d9c1","lab_id":"69ad52a3de79e566650fb33e","country":"PL","accr_number":"AB 631","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Liczba bakterii grupy coli termotolerancyjnych (typ kałowy) oraz Escherichia coli","methodology_en":"Count of thermotolerant coliform bacteria (faecal type) and Escherichia coli","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba bakterii grupy coli termotolerancyjnych (typ kałowy) oraz Escherichia coli\nMetoda filtracji membranowej","reference":"PN-ISO 9308-1:1999","norm_bases":["PN-ISO 9308-1:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Liczba bakterii grupy coli termotolerancyjnych (typ kałowy) oraz Escherichia coli\nMetoda filtracji membranowej PN-ISO 9308-1:1999 Woda, Woda do spozycia przez ludzi Liczba bakterii grupy coli termotolerancyjnych (typ kalowy) oraz Escherichia coli\nMetoda filtracji membranowej PN-ISO 9308-1:1999","categories":["microbiology","water"],"row_index":21,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Count of thermotolerant coliform bacteria (faecal type) and Escherichia coli Membrane filtration method PN-ISO 9308-1:1999","search_zh":"水、生活饮用水 膜过滤法 PN-ISO 9308-1:1999","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9b9f1c10c8ce825d9c2","lab_id":"69ad52a3de79e566650fb33e","country":"PL","accr_number":"AB 631","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Ogólna liczba mikroorganizmów w 22 oC","methodology_en":"Total viable count at 22 oC","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"technique_en":"Plate method (pour plate)","computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w 22 oC\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 22 oC\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda, Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 22 oC\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":22,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Total viable count at 22 oC Plate method (pour plate) PN-EN ISO 6222:2004","methodology_zh":"22 °C 微生物总数","search_zh":"水、生活饮用水 22 °C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9b9f1c10c8ce825d9c3","lab_id":"69ad52a3de79e566650fb33e","country":"PL","accr_number":"AB 631","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Liczba bakterii grupy coli","methodology_en":"Coliform bacteria count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 + A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 + A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 + A1:2017-04 Woda, Woda do spozycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 + A1:2017-04","categories":["water","microbiology"],"row_index":23,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 + A1:2017-04","methodology_zh":"大肠菌群计数","search_zh":"水、生活饮用水 大肠菌群计数 膜过滤法 PN-EN ISO 9308-1:2014-12 + A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9b9f1c10c8ce825d9c4","lab_id":"69ad52a3de79e566650fb33e","country":"PL","accr_number":"AB 631","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Liczba Escherichia coli","methodology_en":"Escherichia coli count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 + A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 + A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 + A1:2017-04 Woda, Woda do spozycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 + A1:2017-04","categories":["water","microbiology"],"row_index":24,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 + A1:2017-04","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"水、生活饮用水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PN-EN ISO 9308-1:2014-12 + A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9b9f1c10c8ce825d9c5","lab_id":"69ad52a3de79e566650fb33e","country":"PL","accr_number":"AB 631","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Liczba paciorkowców kałowych (enterokoków)","methodology_en":"Faecal streptococci (enterococci) count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba paciorkowców kałowych (enterokoków)\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Liczba paciorkowców kałowych (enterokoków)\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda, Woda do spozycia przez ludzi Liczba paciorkowcow kalowych (enterokokow)\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":25,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Faecal streptococci (enterococci) count Membrane filtration method PN-EN ISO 7899-2:2004","search_zh":"水、生活饮用水 粪链球菌（肠球菌）数 膜过滤法 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水","methodology_zh":"粪链球菌（肠球菌）数"},{"_id":"6a5dc9b9f1c10c8ce825d9c6","lab_id":"69ad52a3de79e566650fb33e","country":"PL","accr_number":"AB 631","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Liczba Pseudomonas aeruginosa","methodology_en":"Pseudomonas aeruginosa count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009 Woda, Woda do spozycia przez ludzi Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water"],"row_index":26,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009","methodology_zh":"铜绿假单胞菌计数","search_zh":"水、生活饮用水 铜绿假单胞菌计数 膜过滤法 PN-EN ISO 16266:2009","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9b9f1c10c8ce825d9c7","lab_id":"69ad52a3de79e566650fb33e","country":"PL","accr_number":"AB 631","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Liczba Clostridium perfringens łącznie z przetrwalnikami","methodology_en":"Clostridium perfringens count including spores","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Clostridium perfringens łącznie z przetrwalnikami\nMetoda filtracji membranowej","reference":"PN-EN ISO 14189:2016-10","norm_bases":["PN-EN ISO 14189:2016-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Liczba Clostridium perfringens łącznie z przetrwalnikami\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10 Woda, Woda do spozycia przez ludzi Liczba Clostridium perfringens lacznie z przetrwalnikami\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10","categories":["water"],"row_index":27,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Clostridium perfringens count including spores Membrane filtration method PN-EN ISO 14189:2016-10","search_zh":"水、生活饮用水 产气荚膜梭菌数（含芽孢） 膜过滤法 PN-EN ISO 14189:2016-10","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水","methodology_zh":"产气荚膜梭菌数（含芽孢）"},{"_id":"6a5dc9b9f1c10c8ce825d9c8","lab_id":"69ad52a3de79e566650fb33e","country":"PL","accr_number":"AB 631","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Liczba bakterii z rodzaju Legionella","methodology_en":"Count of bacteria of the genus Legionella","parameters":[{"name":"Matryca A: Procedura 5 (BCYE), 7 (GVPC)"}],"parameters_en":[{"name":"Matrix A: Procedure 5 (BCYE), 7 (GVPC)"}],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba bakterii z rodzaju Legionella\nMatryca A: Procedura 5 (BCYE), 7 (GVPC)\nMetoda filtracji membranowej","reference":"PN-EN ISO 11731: 2017-08 +Ap1:2019-12","norm_bases":["PN-EN ISO 11731: 2017-08 +Ap1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Liczba bakterii z rodzaju Legionella\nMatryca A: Procedura 5 (BCYE), 7 (GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731: 2017-08 +Ap1:2019-12 Woda, Woda do spozycia przez ludzi Liczba bakterii z rodzaju Legionella\nMatryca A: Procedura 5 (BCYE), 7 (GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731: 2017-08 +Ap1:2019-12","categories":["microbiology","water"],"row_index":28,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Count of bacteria of the genus Legionella Membrane filtration method Matrix A: Procedure 5 (BCYE), 7 (GVPC) PN-EN ISO 11731: 2017-08 +Ap1:2019-12","search_zh":"水、生活饮用水 军团菌属细菌计数 膜过滤法 PN-EN ISO 11731: 2017-08 +Ap1:2019-12","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水","methodology_zh":"军团菌属细菌计数"},{"_id":"6a5dc9b9f1c10c8ce825d9c9","lab_id":"69ad52a3de79e566650fb33e","country":"PL","accr_number":"AB 631","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi","test_object_en":"Water (including swimming pool water), Water intended for human consumption","methodology":"Ogólna liczba mikroorganizmów w 36 oC","methodology_en":"Total viable count at 36 oC","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"technique_en":"Plate method (pour plate)","computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w 36 oC\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 36 oC\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda (w tym woda na plywalniach), Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 36 oC\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":29,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water (including swimming pool water), Water intended for human consumption Total viable count at 36 oC Plate method (pour plate) PN-EN ISO 6222:2004","methodology_zh":"36 °C 微生物总数","search_zh":"水（含游泳池水）、生活饮用水 36 °C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a5dc9b9f1c10c8ce825d9ca","lab_id":"69ad52a3de79e566650fb33e","country":"PL","accr_number":"AB 631","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi","test_object_en":"Water (including swimming pool water), Water intended for human consumption","methodology":"Liczba Pseudomonas aeruginosa","methodology_en":"Pseudomonas aeruginosa count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009 Woda (w tym woda na plywalniach), Woda do spozycia przez ludzi Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water"],"row_index":30,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water (including swimming pool water), Water intended for human consumption Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009","methodology_zh":"铜绿假单胞菌计数","search_zh":"水（含游泳池水）、生活饮用水 铜绿假单胞菌计数 膜过滤法 PN-EN ISO 16266:2009","technique_zh":"膜过滤法","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a5dc9b9f1c10c8ce825d9cb","lab_id":"69ad52a3de79e566650fb33e","country":"PL","accr_number":"AB 631","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi","test_object_en":"Water (including swimming pool water), Water intended for human consumption","methodology":"Liczba gronkowców koagulazododatnich","methodology_en":"Coagulase-positive staphylococci count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba gronkowców koagulazododatnich\nMetoda filtracji membranowej","reference":"Metodyka PZH ZHK:2007","norm_bases":["Metodyka PZH ZHK:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi Liczba gronkowców koagulazododatnich\nMetoda filtracji membranowej Metodyka PZH ZHK:2007 Woda (w tym woda na plywalniach), Woda do spozycia przez ludzi Liczba gronkowcow koagulazododatnich\nMetoda filtracji membranowej Metodyka PZH ZHK:2007","categories":["water"],"row_index":31,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water (including swimming pool water), Water intended for human consumption Coagulase-positive staphylococci count Membrane filtration method Metodyka PZH ZHK:2007","search_zh":"水（含游泳池水）、生活饮用水 凝固酶阳性葡萄球菌计数 膜过滤法 Metodyka PZH ZHK:2007","technique_zh":"膜过滤法","methodology_zh":"凝固酶阳性葡萄球菌计数","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a5dc9b9f1c10c8ce825d9cc","lab_id":"69ad52a3de79e566650fb33e","country":"PL","accr_number":"AB 631","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi","test_object_en":"Water (including swimming pool water), Water intended for human consumption","methodology":"Liczba Escherichia coli","methodology_en":"Escherichia coli count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014- 12 + A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014- 12 + A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014- 12 + A1:2017-04 Woda (w tym woda na plywalniach), Woda do spozycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014- 12 + A1:2017-04","categories":["water","microbiology"],"row_index":32,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water (including swimming pool water), Water intended for human consumption Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014- 12 + A1:2017-04","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"水（含游泳池水）、生活饮用水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PN-EN ISO 9308-1:2014- 12 + A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a5dc9b9f1c10c8ce825d9cd","lab_id":"69ad52a3de79e566650fb33e","country":"PL","accr_number":"AB 631","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach)","test_object_en":"Water (including swimming pool water)","methodology":"Liczba bakterii z rodzaju Legionella","methodology_en":"Count of bacteria of the genus Legionella","parameters":[{"name":"Matryca B: Procedura 7 (GVPC)"}],"parameters_en":[{"name":"Matrix B: Procedure 7 (GVPC)"}],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba bakterii z rodzaju Legionella\nMatryca B: Procedura 7 (GVPC)\nMetoda filtracji membranowej","reference":"PN-EN ISO 11731: 2017-08 +Ap1:2019-12","norm_bases":["PN-EN ISO 11731: 2017-08 +Ap1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach) Liczba bakterii z rodzaju Legionella\nMatryca B: Procedura 7 (GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731: 2017-08 +Ap1:2019-12 Woda (w tym woda na plywalniach) Liczba bakterii z rodzaju Legionella\nMatryca B: Procedura 7 (GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731: 2017-08 +Ap1:2019-12","categories":["microbiology","water"],"row_index":33,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water (including swimming pool water) Count of bacteria of the genus Legionella Membrane filtration method Matrix B: Procedure 7 (GVPC) PN-EN ISO 11731: 2017-08 +Ap1:2019-12","search_zh":"水（含游泳池水） 军团菌属细菌计数 膜过滤法 PN-EN ISO 11731: 2017-08 +Ap1:2019-12","technique_zh":"膜过滤法","methodology_zh":"军团菌属细菌计数","test_object_zh":"水（含游泳池水）"},{"_id":"6a5dc9b9f1c10c8ce825d9ce","lab_id":"69ad52a3de79e566650fb33e","country":"PL","accr_number":"AB 631","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Najbardziej prawdopodobna liczba, Escherichia coli","methodology_en":"Most probable number, Escherichia coli","parameters":[],"parameters_en":[],"technique":"Metoda zminiaturyzowana (NPL)","techniques":["Metoda zminiaturyzowana (NPL)"],"technique_en":"Miniaturized method (MPN)","computed":[],"computed_en":[],"activity":"Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda zminiaturyzowana (NPL)","reference":"PN-EN ISO 9308-3:2002","norm_bases":["PN-EN ISO 9308-3:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda zminiaturyzowana (NPL) PN-EN ISO 9308-3:2002 Woda Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda zminiaturyzowana (NPL) PN-EN ISO 9308-3:2002","categories":["water","microbiology"],"row_index":34,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Most probable number, Escherichia coli Miniaturized method (MPN) PN-EN ISO 9308-3:2002","methodology_zh":"大肠埃希氏菌（Escherichia coli）最可能数（MPN）","search_zh":"水 大肠埃希氏菌（Escherichia coli）最可能数（MPN） 微量法（MPN） PN-EN ISO 9308-3:2002","test_object_zh":"水","technique_zh":"微量法（MPN）"},{"_id":"6a5dc9b9f1c10c8ce825d9cf","lab_id":"69ad52a3de79e566650fb33e","country":"PL","accr_number":"AB 631","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Najbardziej prawdopodobna liczba enterokoków kałowych","methodology_en":"Most probable number of intestinal enterococci","parameters":[],"parameters_en":[],"technique":"Metoda zminiaturyzowana (NPL)","techniques":["Metoda zminiaturyzowana (NPL)"],"technique_en":"Miniaturized method (MPN)","computed":[],"computed_en":[],"activity":"Najbardziej prawdopodobna liczba enterokoków kałowych\nMetoda zminiaturyzowana (NPL)","reference":"PN-EN ISO 7899-1:2002","norm_bases":["PN-EN ISO 7899-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Najbardziej prawdopodobna liczba enterokoków kałowych\nMetoda zminiaturyzowana (NPL) PN-EN ISO 7899-1:2002 Woda Najbardziej prawdopodobna liczba enterokokow kalowych\nMetoda zminiaturyzowana (NPL) PN-EN ISO 7899-1:2002","categories":["water"],"row_index":35,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Most probable number of intestinal enterococci Miniaturized method (MPN) PN-EN ISO 7899-1:2002","search_zh":"水 粪肠球菌最可能数 微量法（MPN） PN-EN ISO 7899-1:2002","test_object_zh":"水","technique_zh":"微量法（MPN）","methodology_zh":"粪肠球菌最可能数"}],"has_pdf":true}