{"lab":{"_id":"69ad52a3de79e566650fb338","accr_number":"AB 626","country":"PL","accr_body":"PCA","address":"ul. 11 Listopada 15, 42-400 Zawiercie","categories":["water","microbiology"],"city":"Zawiercie","imported_at":"2026-03-08T10:42:43.265Z","methods_count":29,"name":"POWIATOWA STACJA SANITARNO-EPIDEMIOLOGICZNA W ZAWIERCIU","parse_status":"parsed","parse_version":2,"pdf_files":["AB_626.pdf"],"scope_summary":"","search_text":"powiatowa stacja sanitarno-epidemiologiczna w zawierciu ul. 11 listopada 15, 42-400 zawiercie water other materials pharma electronics microbiology automotive food","status":"active","updated_at":"2026-03-08T14:51:31.731Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-17T21:02:27.068Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20626,podmiot.html","fields_of_testing":[{"codes":"C/28; C/29","pl":"Badania chemiczne wody, wody do spożycia przez ludzi","en":"Chemical tests of water, drinking water"},{"codes":"K/3; K/28; K/29","pl":"Badania mikrobiologiczne obiektów i materiałów biologicznych przeznaczonych do badań, wody, wody do spożycia przez ludzi","en":"Microbiological tests of of biological items and materials for testing, water, drinking water"},{"codes":"N/28; N/29","pl":"Badanie właściwości fizycznych wody, wody do spożycia przez ludzi","en":"Tests of physical properties of water, drinking water"},{"codes":"Q/29","pl":"Badania sensoryczne wody do spożycia przez ludzi","en":"Sensory tests of drinking water"}],"issue":{"no":"21","date":"22.07.2026"},"parse_date":"2026-08-17T21:02:27.068Z","parse_source":"agent-claude-code","map_coord":[50.493346,19.417354],"map_geo":"nominatim-street","lab_locations":[{"name":"Oddział Laboratoryjny","address":"ul.11 Listopada 15,42-400 Zawiercie","city":"Zawiercie","postal":"42-400"},{"name":"Sekcja Badań Higieny Środowiska","address":"ul.11 Listopada 15,42-400 Zawiercie","city":"Zawiercie","postal":"42-400"},{"name":"Sekcja Badań Chorób Zakaźnych i Zakażeń","address":"ul.11 Listopada 15,42-400 Zawiercie","city":"Zawiercie","postal":"42-400"}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/2dad303f4202a305b4432fd52ca343a6/AB%20626.pdf","has_en":true,"category_counts":{"water":27,"microbiology":9},"category_scores":{"water":20.25,"microbiology":2.25},"has_zh":true},"methods":[{"_id":"6a8376e3af14b9c0e7b1f725","lab_id":"69ad52a3de79e566650fb338","country":"PL","accr_number":"AB 626","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5,0 – 400) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5,0 – 400) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Higieny Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie chlorków\nZakres (5,0 – 400) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda Stezenie chlorkow\nZakres (5,0 – 400) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5,0 – 400) mg/l"}],"search_en":"Water Chloride concentration Titrimetric method Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Water","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,0 – 400) mg/l"}],"search_zh":"水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水"},{"_id":"6a8376e3af14b9c0e7b1f726","lab_id":"69ad52a3de79e566650fb338","country":"PL","accr_number":"AB 626","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,003 – 0,25) mg/l"},{"name":"Stężenie azotynów"},{"name":"Zakres","range":"(0,01 – 0,80) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres:\nZakres (0,003 – 0,25) mg/l\nStężenie azotynów\nZakres (0,01 – 0,80) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Higieny Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie azotu azotynowego\nZakres:\nZakres (0,003 – 0,25) mg/l\nStężenie azotynów\nZakres (0,01 – 0,80) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda Stezenie azotu azotynowego\nZakres:\nZakres (0,003 – 0,25) mg/l\nStezenie azotynow\nZakres (0,01 – 0,80) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,003 – 0,25) mg/l"},{"name":"Nitrite concentration"},{"name":"Range","range":"(0,01 – 0,80) mg/l"}],"search_en":"Water Nitrite nitrogen concentration Spectrophotometric method Range Nitrite concentration Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,003 – 0,25) mg/l"},{"name":"亚硝酸盐浓度"},{"name":"范围","range":"(0,01 – 0,80) mg/l"}],"search_zh":"水 亚硝态氮浓度 分光光度法 范围 亚硝酸盐浓度 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水"},{"_id":"6a8376e3af14b9c0e7b1f727","lab_id":"69ad52a3de79e566650fb338","country":"PL","accr_number":"AB 626","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,04 – 2,0) mg/l"},{"name":"Stężenie jonu amonowego"},{"name":"Zakres","range":"(0,05 – 2,6) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres:\nZakres (0,04 – 2,0) mg/l\nStężenie jonu amonowego\nZakres (0,05 – 2,6) mg/l\nMetoda spektrofotometryczna","reference":"PN-C-04576-4:1994","norm_bases":["PN-C-04576-4:1994"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Higieny Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie azotu amonowego\nZakres:\nZakres (0,04 – 2,0) mg/l\nStężenie jonu amonowego\nZakres (0,05 – 2,6) mg/l\nMetoda spektrofotometryczna PN-C-04576-4:1994 Woda Stezenie azotu amonowego\nZakres:\nZakres (0,04 – 2,0) mg/l\nStezenie jonu amonowego\nZakres (0,05 – 2,6) mg/l\nMetoda spektrofotometryczna PN-C-04576-4:1994","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,04 – 2,0) mg/l"},{"name":"Ammonium ion concentration"},{"name":"Range","range":"(0,05 – 2,6) mg/l"}],"search_en":"Water Ammonium nitrogen concentration Spectrophotometric method Range Ammonium ion concentration Range PN-C-04576-4:1994","technique_en":"Spectrophotometric method","test_object_en":"Water","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,04 – 2,0) mg/l"},{"name":"铵离子浓度"},{"name":"范围","range":"(0,05 – 2,6) mg/l"}],"search_zh":"水 氨氮浓度 分光光度法 范围 铵离子浓度 范围 PN-C-04576-4:1994","technique_zh":"分光光度法","test_object_zh":"水"},{"_id":"6a8376e3af14b9c0e7b1f728","lab_id":"69ad52a3de79e566650fb338","country":"PL","accr_number":"AB 626","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie manganu ogólnego","parameters":[{"name":"Zakres","range":"(0,015 – 2,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie manganu ogólnego\nZakres (0,015 – 2,0) mg/l\nMetoda spektrofotometryczna","reference":"Instrukcja Producenta Testu Spectroquant nr 14770 Merck wydanie: Lipiec 2024","norm_bases":["Instrukcja Producenta Testu Spectroquant nr 14770 Merck wydanie: Lipiec 2024"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Higieny Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie manganu ogólnego\nZakres (0,015 – 2,0) mg/l\nMetoda spektrofotometryczna Instrukcja Producenta Testu Spectroquant nr 14770 Merck wydanie: Lipiec 2024 Woda Stezenie manganu ogolnego\nZakres (0,015 – 2,0) mg/l\nMetoda spektrofotometryczna Instrukcja Producenta Testu Spectroquant nr 14770 Merck wydanie: Lipiec 2024","categories":["water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total manganese concentration","parameters_en":[{"name":"Range","range":"(0,015 – 2,0) mg/l"}],"search_en":"Water Total manganese concentration Spectrophotometric method Range Instrukcja Producenta Testu Spectroquant nr 14770 Merck wydanie: Lipiec 2024","technique_en":"Spectrophotometric method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,015 – 2,0) mg/l"}],"search_zh":"水 总锰浓度 分光光度法 范围 Instrukcja Producenta Testu Spectroquant nr 14770 Merck wydanie: Lipiec 2024","technique_zh":"分光光度法","test_object_zh":"水","methodology_zh":"总锰浓度"},{"_id":"6a8376e3af14b9c0e7b1f729","lab_id":"69ad52a3de79e566650fb338","country":"PL","accr_number":"AB 626","accr_body":"PCA","test_object":"Woda","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(2-70) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Barwa\nZakres (2-70) mg/l Pt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012+ Ap1:2015-06 metoda C","norm_bases":["PN-EN ISO 7887:2012+ Ap1:2015-06 metoda C"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Higieny Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Barwa\nZakres (2-70) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012+ Ap1:2015-06 metoda C Woda Barwa\nZakres (2-70) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012+ Ap1:2015-06 metoda C","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"(2-70) mg/l Pt"}],"search_en":"Water Colour Spectrophotometric method Range PN-EN ISO 7887:2012+ Ap1:2015-06 metoda C","technique_en":"Spectrophotometric method","test_object_en":"Water","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(2-70) mg/l Pt"}],"search_zh":"水 色度 分光光度法 范围 PN-EN ISO 7887:2012+ Ap1:2015-06 metoda C","technique_zh":"分光光度法","test_object_zh":"水"},{"_id":"6a8376e3af14b9c0e7b1f72a","lab_id":"69ad52a3de79e566650fb338","country":"PL","accr_number":"AB 626","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie żelaza ogólnego","parameters":[{"name":"Zakres","range":"(0,03 – 2,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza ogólnego\nZakres (0,03 – 2,0) mg/l\nMetoda spektrofotometryczna","reference":"Instrukcja Producenta Testu Spectroquant nr 14761 Merck Wydanie: Marzec 2024","norm_bases":["Instrukcja Producenta Testu Spectroquant nr 14761 Merck Wydanie: Marzec 2024"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Higieny Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie żelaza ogólnego\nZakres (0,03 – 2,0) mg/l\nMetoda spektrofotometryczna Instrukcja Producenta Testu Spectroquant nr 14761 Merck Wydanie: Marzec 2024 Woda Stezenie zelaza ogolnego\nZakres (0,03 – 2,0) mg/l\nMetoda spektrofotometryczna Instrukcja Producenta Testu Spectroquant nr 14761 Merck Wydanie: Marzec 2024","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total iron concentration","parameters_en":[{"name":"Range","range":"(0,03 – 2,0) mg/l"}],"search_en":"Water Total iron concentration Spectrophotometric method Range Instrukcja Producenta Testu Spectroquant nr 14761 Merck Wydanie: Marzec 2024","technique_en":"Spectrophotometric method","test_object_en":"Water","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(0,03 – 2,0) mg/l"}],"search_zh":"水 总铁浓度 分光光度法 范围 Instrukcja Producenta Testu Spectroquant nr 14761 Merck Wydanie: Marzec 2024","technique_zh":"分光光度法","test_object_zh":"水"},{"_id":"6a8376e3af14b9c0e7b1f72b","lab_id":"69ad52a3de79e566650fb338","country":"PL","accr_number":"AB 626","accr_body":"PCA","test_object":"Woda","methodology":"Sumaryczne stężenie wapnia i magnezu (twardość ogólna)","parameters":[{"name":"Zakres","range":"(5,0 – 500) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Sumaryczne stężenie wapnia i magnezu (twardość ogólna)\nZakres (5,0 – 500) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Higieny Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Sumaryczne stężenie wapnia i magnezu (twardość ogólna)\nZakres (5,0 – 500) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999 Woda Sumaryczne stezenie wapnia i magnezu (twardosc ogolna)\nZakres (5,0 – 500) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total concentration of calcium and magnesium (total hardness)","parameters_en":[{"name":"Range","range":"(5,0 – 500) mg/l CaCO3"}],"search_en":"Water Total concentration of calcium and magnesium (total hardness) Titrimetric method Range PN-ISO 6059:1999","technique_en":"Titrimetric method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(5,0 – 500) mg/l CaCO3"}],"search_zh":"水 钙与镁的总浓度（总硬度） 滴定法 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"水","methodology_zh":"钙与镁的总浓度（总硬度）"},{"_id":"6a8376e3af14b9c0e7b1f72c","lab_id":"69ad52a3de79e566650fb338","country":"PL","accr_number":"AB 626","accr_body":"PCA","test_object":"Woda","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(100 – 2 500) µS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (100 – 2 500) µS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Higieny Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Przewodność elektryczna właściwa\nZakres (100 – 2 500) µS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda Przewodnosc elektryczna wlasciwa\nZakres (100 – 2 500) µS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(100 – 2 500) µS/cm"}],"search_en":"Water Electrical conductivity Conductometric method Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(100 – 2 500) µS/cm"}],"search_zh":"水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水"},{"_id":"6a8376e3af14b9c0e7b1f72d","lab_id":"69ad52a3de79e566650fb338","country":"PL","accr_number":"AB 626","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba progowa smaku (TFN) Liczba progowa zapachu (TON)","parameters":[{"name":"Zakres","range":"1-2"}],"technique":"Metoda: parzysta, wyboru niewymuszonego, uproszczona","techniques":["Metoda: parzysta, wyboru niewymuszonego, uproszczona"],"computed":[],"activity":"Liczba progowa smaku (TFN) Liczba progowa zapachu (TON)\nZakres 1-2\nMetoda: parzysta, wyboru niewymuszonego, uproszczona","reference":"PN-EN 1622:2006","norm_bases":["PN-EN 1622:2006"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Higieny Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba progowa smaku (TFN) Liczba progowa zapachu (TON)\nZakres 1-2\nMetoda: parzysta, wyboru niewymuszonego, uproszczona PN-EN 1622:2006 Woda do spozycia przez ludzi Liczba progowa smaku (TFN) Liczba progowa zapachu (TON)\nZakres 1-2\nMetoda: parzysta, wyboru niewymuszonego, uproszczona PN-EN 1622:2006","categories":["water"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Threshold flavour number (TFN) Threshold odour number (TON)","parameters_en":[{"name":"Range","range":"1-2"}],"search_en":"Water intended for human consumption Threshold flavour number (TFN) Threshold odour number (TON) Range PN-EN 1622:2006","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"1-2"}],"search_zh":"生活饮用水 范围 PN-EN 1622:2006","test_object_zh":"生活饮用水"},{"_id":"6a8376e3af14b9c0e7b1f72e","lab_id":"69ad52a3de79e566650fb338","country":"PL","accr_number":"AB 626","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach)","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Higieny Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach) pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda (w tym woda na plywalniach) pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"search_en":"Water (including swimming pool water) pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water (including swimming pool water)","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"水（含游泳池水） pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水（含游泳池水）"},{"_id":"6a8376e3af14b9c0e7b1f72f","lab_id":"69ad52a3de79e566650fb338","country":"PL","accr_number":"AB 626","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach)","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,10 – 40) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,10 – 40) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Higieny Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach) Mętność\nZakres (0,10 – 40) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda (w tym woda na plywalniach) Metnosc\nZakres (0,10 – 40) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,10 – 40) NTU"}],"search_en":"Water (including swimming pool water) Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09","technique_en":"Nephelometric method","test_object_en":"Water (including swimming pool water)","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,10 – 40) NTU"}],"search_zh":"水（含游泳池水） 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"水（含游泳池水）"},{"_id":"6a8376e3af14b9c0e7b1f730","lab_id":"69ad52a3de79e566650fb338","country":"PL","accr_number":"AB 626","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach)","methodology":"Stężenie azotu azotanowego","parameters":[{"name":"Zakres","range":"(0,1 – 20,0) mg/l"},{"name":"Stężenie azotanów"},{"name":"Zakres","range":"(0,4 – 90,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotanowego\nZakres:\nZakres (0,1 – 20,0) mg/l\nStężenie azotanów\nZakres (0,4 – 90,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Higieny Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach) Stężenie azotu azotanowego\nZakres:\nZakres (0,1 – 20,0) mg/l\nStężenie azotanów\nZakres (0,4 – 90,0) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08 Woda (w tym woda na plywalniach) Stezenie azotu azotanowego\nZakres:\nZakres (0,1 – 20,0) mg/l\nStezenie azotanow\nZakres (0,4 – 90,0) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,1 – 20,0) mg/l"},{"name":"Nitrate concentration"},{"name":"Range","range":"(0,4 – 90,0) mg/l"}],"search_en":"Water (including swimming pool water) Nitrate nitrogen concentration Spectrophotometric method Range Nitrate concentration Range PN-82/C-04576/08","technique_en":"Spectrophotometric method","test_object_en":"Water (including swimming pool water)","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,1 – 20,0) mg/l"},{"name":"硝酸盐浓度"},{"name":"范围","range":"(0,4 – 90,0) mg/l"}],"search_zh":"水（含游泳池水） 硝态氮浓度 分光光度法 范围 硝酸盐浓度 范围 PN-82/C-04576/08","technique_zh":"分光光度法","test_object_zh":"水（含游泳池水）"},{"_id":"6a8376e3af14b9c0e7b1f731","lab_id":"69ad52a3de79e566650fb338","country":"PL","accr_number":"AB 626","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Stężenie chloru wolnego","parameters":[{"name":"Zakres","range":"(0,10 – 2,00) mg Cl2/l"},{"name":"Stężenie chloru ogólnego"},{"name":"Zakres","range":"(0,10 – 2,00) mg Cl2/l"},{"name":"Stężenie chloru związanego (z obliczeń)"}],"technique":"Metoda kolorymetryczna","techniques":["Metoda kolorymetryczna"],"computed":[],"activity":"Stężenie chloru wolnego\nZakres:\nZakres (0,10 – 2,00) mg Cl2/l\nStężenie chloru ogólnego\nZakres (0,10 – 2,00) mg Cl2/l\nStężenie chloru związanego (z obliczeń)\nMetoda kolorymetryczna","reference":"OL/PB-06 wydanie 2 z dnia 02.01.2020 r. | na podstawie testu Hanna Instruments HI 96711-11 chlor ogólny HI 96701-11 chlor wolny","norm_bases":["OL/PB-06 wydanie 2 z dnia 02.01.2020 r.","na podstawie testu Hanna Instruments HI 96711-11 chlor ogólny HI 96701-11 chlor wolny"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Higieny Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Stężenie chloru wolnego\nZakres:\nZakres (0,10 – 2,00) mg Cl2/l\nStężenie chloru ogólnego\nZakres (0,10 – 2,00) mg Cl2/l\nStężenie chloru związanego (z obliczeń)\nMetoda kolorymetryczna OL/PB-06 wydanie 2 z dnia 02.01.2020 r. | na podstawie testu Hanna Instruments HI 96711-11 chlor ogólny HI 96701-11 chlor wolny Woda na plywalniach Stezenie chloru wolnego\nZakres:\nZakres (0,10 – 2,00) mg Cl2/l\nStezenie chloru ogolnego\nZakres (0,10 – 2,00) mg Cl2/l\nStezenie chloru zwiazanego (z obliczen)\nMetoda kolorymetryczna OL/PB-06 wydanie 2 z dnia 02.01.2020 r. | na podstawie testu Hanna Instruments HI 96711-11 chlor ogolny HI 96701-11 chlor wolny","categories":["water"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free chlorine concentration","parameters_en":[{"name":"Range","range":"(0,10 – 2,00) mg Cl2/l"},{"name":"Total chlorine concentration"},{"name":"Range","range":"(0,10 – 2,00) mg Cl2/l"},{"name":"Combined chlorine concentration (calculated)"}],"search_en":"Swimming pool water Free chlorine concentration Colorimetric method Range Total chlorine concentration Range Combined chlorine concentration (calculated) OL/PB-06 wydanie 2 z dnia 02.01.2020 r. | na podstawie testu Hanna Instruments HI 96711-11 chlor ogólny HI 96701-11 chlor wolny","technique_en":"Colorimetric method","test_object_en":"Swimming pool water","methodology_zh":"游离氯浓度","parameters_zh":[{"name":"范围","range":"(0,10 – 2,00) mg Cl2/l"},{"name":"总氯浓度"},{"name":"范围","range":"(0,10 – 2,00) mg Cl2/l"},{"name":"化合氯浓度（计算值）"}],"search_zh":"游泳池水 游离氯浓度 比色法 范围 总氯浓度 范围 化合氯浓度（计算值） OL/PB-06 wydanie 2 z dnia 02.01.2020 r. | na podstawie testu Hanna Instruments HI 96711-11 chlor ogólny HI 96701-11 chlor wolny","technique_zh":"比色法","test_object_zh":"游泳池水"},{"_id":"6a8376e3af14b9c0e7b1f732","lab_id":"69ad52a3de79e566650fb338","country":"PL","accr_number":"AB 626","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Potencjał utleniający-redukujący (redoks) wzgl. Ag/AgCl 3,5 mol/l KCl","parameters":[{"name":"Zakres","range":"(200 – 1000) mV"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"Potencjał utleniający-redukujący (redoks) wzgl. Ag/AgCl 3,5 mol/l KCl\nZakres (200 – 1000) mV\nMetoda potencjometryczna","reference":"OL/PB-07 wydanie 2 z dnia 02.01.2020 r.","norm_bases":["OL/PB-07 wydanie 2 z dnia 02.01.2020 r."],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Higieny Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Potencjał utleniający-redukujący (redoks) wzgl. Ag/AgCl 3,5 mol/l KCl\nZakres (200 – 1000) mV\nMetoda potencjometryczna OL/PB-07 wydanie 2 z dnia 02.01.2020 r. Woda na plywalniach Potencjal utleniajacy-redukujacy (redoks) wzgl. Ag/AgCl 3,5 mol/l KCl\nZakres (200 – 1000) mV\nMetoda potencjometryczna OL/PB-07 wydanie 2 z dnia 02.01.2020 r.","categories":["water"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Oxidising-reducing (redox) potential ref. to Ag/AgCl 3,5 mol/l KCl","parameters_en":[{"name":"Range","range":"(200 – 1000) mV"}],"search_en":"Swimming pool water Oxidising-reducing (redox) potential ref. to Ag/AgCl 3,5 mol/l KCl Potentiometric method Range OL/PB-07 wydanie 2 z dnia 02.01.2020 r.","technique_en":"Potentiometric method","test_object_en":"Swimming pool water","parameters_zh":[{"name":"范围","range":"(200 – 1000) mV"}],"search_zh":"游泳池水 电位法 范围 OL/PB-07 wydanie 2 z dnia 02.01.2020 r.","technique_zh":"电位法","test_object_zh":"游泳池水"},{"_id":"6a8376e3af14b9c0e7b1f733","lab_id":"69ad52a3de79e566650fb338","country":"PL","accr_number":"AB 626","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Liczba bakterii grupy coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-ISO 9308-1:1999","norm_bases":["PN-ISO 9308-1:1999"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Higieny Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-ISO 9308-1:1999 Woda, Woda do spozycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-ISO 9308-1:1999","categories":["water","microbiology"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Coliform bacteria count","search_en":"Water, Water intended for human consumption Coliform bacteria count Membrane filtration method PN-ISO 9308-1:1999","technique_en":"Membrane filtration method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"大肠菌群计数","search_zh":"水、生活饮用水 大肠菌群计数 膜过滤法 PN-ISO 9308-1:1999","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a8376e3af14b9c0e7b1f734","lab_id":"69ad52a3de79e566650fb338","country":"PL","accr_number":"AB 626","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Liczba bakterii grupy coli termotolerancyjnych, Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii grupy coli termotolerancyjnych, Escherichia coli\nMetoda filtracji membranowej","reference":"PN-ISO 9308-1:1999","norm_bases":["PN-ISO 9308-1:1999"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Higieny Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Liczba bakterii grupy coli termotolerancyjnych, Escherichia coli\nMetoda filtracji membranowej PN-ISO 9308-1:1999 Woda, Woda do spozycia przez ludzi Liczba bakterii grupy coli termotolerancyjnych, Escherichia coli\nMetoda filtracji membranowej PN-ISO 9308-1:1999","categories":["microbiology","water"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Count of thermotolerant coliform bacteria, Escherichia coli","search_en":"Water, Water intended for human consumption Count of thermotolerant coliform bacteria, Escherichia coli Membrane filtration method PN-ISO 9308-1:1999","technique_en":"Membrane filtration method","test_object_en":"Water, Water intended for human consumption","search_zh":"水、生活饮用水 膜过滤法 PN-ISO 9308-1:1999","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a8376e3af14b9c0e7b1f735","lab_id":"69ad52a3de79e566650fb338","country":"PL","accr_number":"AB 626","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w temperaturze 36 °C","parameters":[],"technique":"Metoda płytkowa, posiew wgłębny","techniques":["Metoda płytkowa, posiew wgłębny"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w temperaturze 36 °C\nMetoda płytkowa, posiew wgłębny","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Higieny Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w temperaturze 36 °C\nMetoda płytkowa, posiew wgłębny PN-EN ISO 6222:2004 Woda, Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w temperaturze 36 °C\nMetoda plytkowa, posiew wglebny PN-EN ISO 6222:2004","categories":["water"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total viable count at 36 °C","search_en":"Water, Water intended for human consumption Total viable count at 36 °C Plate method, pour plate PN-EN ISO 6222:2004","technique_en":"Plate method, pour plate","test_object_en":"Water, Water intended for human consumption","search_zh":"水、生活饮用水 36 °C 微生物总数 平板法，倾注平板 PN-EN ISO 6222:2004","test_object_zh":"水、生活饮用水","technique_zh":"平板法，倾注平板","methodology_zh":"36 °C 微生物总数"},{"_id":"6a8376e3af14b9c0e7b1f736","lab_id":"69ad52a3de79e566650fb338","country":"PL","accr_number":"AB 626","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w temperaturze 22 °C","parameters":[],"technique":"Metoda płytkowa, posiew wgłębny","techniques":["Metoda płytkowa, posiew wgłębny"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w temperaturze 22 °C\nMetoda płytkowa, posiew wgłębny","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Higieny Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w temperaturze 22 °C\nMetoda płytkowa, posiew wgłębny PN-EN ISO 6222:2004 Woda, Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w temperaturze 22 °C\nMetoda plytkowa, posiew wglebny PN-EN ISO 6222:2004","categories":["water"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total viable count at 22 °C","search_en":"Water, Water intended for human consumption Total viable count at 22 °C Plate method, pour plate PN-EN ISO 6222:2004","technique_en":"Plate method, pour plate","test_object_en":"Water, Water intended for human consumption","search_zh":"水、生活饮用水 22 °C 微生物总数 平板法，倾注平板 PN-EN ISO 6222:2004","test_object_zh":"水、生活饮用水","technique_zh":"平板法，倾注平板","methodology_zh":"22 °C 微生物总数"},{"_id":"6a8376e3af14b9c0e7b1f737","lab_id":"69ad52a3de79e566650fb338","country":"PL","accr_number":"AB 626","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Liczba enterokoków","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba enterokoków\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Higieny Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Liczba enterokoków\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda, Woda do spozycia przez ludzi Liczba enterokokow\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Enterococci count","search_en":"Water, Water intended for human consumption Enterococci count Membrane filtration method PN-EN ISO 7899-2:2004","technique_en":"Membrane filtration method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"肠球菌计数","search_zh":"水、生活饮用水 肠球菌计数 膜过滤法 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a8376e3af14b9c0e7b1f738","lab_id":"69ad52a3de79e566650fb338","country":"PL","accr_number":"AB 626","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Liczba bakterii grupy coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308 -1:2014-12+ A1:2017- 04","norm_bases":["PN-EN ISO 9308 -1:2014-12+ A1:2017- 04"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Higieny Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308 -1:2014-12+ A1:2017- 04 Woda, Woda do spozycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308 -1:2014-12+ A1:2017- 04","categories":["water","microbiology"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Coliform bacteria count","search_en":"Water, Water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308 -1:2014-12+ A1:2017- 04","technique_en":"Membrane filtration method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"大肠菌群计数","search_zh":"水、生活饮用水 大肠菌群计数 膜过滤法 PN-EN ISO 9308 -1:2014-12+ A1:2017- 04","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a8376e3af14b9c0e7b1f739","lab_id":"69ad52a3de79e566650fb338","country":"PL","accr_number":"AB 626","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Liczba Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308 -1:2014-12 +A1:2017 -04","norm_bases":["PN-EN ISO 9308 -1:2014-12 +A1:2017 -04"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Higieny Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308 -1:2014-12 +A1:2017 -04 Woda, Woda do spozycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308 -1:2014-12 +A1:2017 -04","categories":["water","microbiology"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Escherichia coli count","search_en":"Water, Water intended for human consumption Escherichia coli count Membrane filtration method PN-EN ISO 9308 -1:2014-12 +A1:2017 -04","technique_en":"Membrane filtration method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"水、生活饮用水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PN-EN ISO 9308 -1:2014-12 +A1:2017 -04","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a8376e3af14b9c0e7b1f73a","lab_id":"69ad52a3de79e566650fb338","country":"PL","accr_number":"AB 626","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Liczba bakterii z rodzaju Legionella, Matryca B: Procedura 7 – Podłoże C (GVPC)","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii z rodzaju Legionella, Matryca B: Procedura 7 – Podłoże C (GVPC)\nMetoda filtracji membranowej","reference":"PN-EN ISO 11731:2017-08 + Ap1:2019-12","norm_bases":["PN-EN ISO 11731:2017-08 + Ap1:2019-12"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Higieny Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Liczba bakterii z rodzaju Legionella, Matryca B: Procedura 7 – Podłoże C (GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 + Ap1:2019-12 Woda, Woda do spozycia przez ludzi Liczba bakterii z rodzaju Legionella, Matryca B: Procedura 7 – Podloze C (GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 + Ap1:2019-12","categories":["microbiology","water"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Water, Water intended for human consumption Membrane filtration method PN-EN ISO 11731:2017-08 + Ap1:2019-12","technique_en":"Membrane filtration method","test_object_en":"Water, Water intended for human consumption","search_zh":"水、生活饮用水 膜过滤法 PN-EN ISO 11731:2017-08 + Ap1:2019-12","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a8376e3af14b9c0e7b1f73b","lab_id":"69ad52a3de79e566650fb338","country":"PL","accr_number":"AB 626","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Liczba Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308 -1:2014-12 +A1:2017 -04","norm_bases":["PN-EN ISO 9308 -1:2014-12 +A1:2017 -04"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Higieny Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308 -1:2014-12 +A1:2017 -04 Woda na plywalniach Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308 -1:2014-12 +A1:2017 -04","categories":["water","microbiology"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Escherichia coli count","search_en":"Swimming pool water Escherichia coli count Membrane filtration method PN-EN ISO 9308 -1:2014-12 +A1:2017 -04","technique_en":"Membrane filtration method","test_object_en":"Swimming pool water","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"游泳池水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PN-EN ISO 9308 -1:2014-12 +A1:2017 -04","technique_zh":"膜过滤法","test_object_zh":"游泳池水"},{"_id":"6a8376e3af14b9c0e7b1f73c","lab_id":"69ad52a3de79e566650fb338","country":"PL","accr_number":"AB 626","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Ogólna liczba mikroorganizmów w temperaturze 36 °C","parameters":[],"technique":"Metoda płytkowa, posiew wgłębny","techniques":["Metoda płytkowa, posiew wgłębny"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w temperaturze 36 °C\nMetoda płytkowa, posiew wgłębny","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Higieny Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Ogólna liczba mikroorganizmów w temperaturze 36 °C\nMetoda płytkowa, posiew wgłębny PN-EN ISO 6222:2004 Woda na plywalniach Ogolna liczba mikroorganizmow w temperaturze 36 °C\nMetoda plytkowa, posiew wglebny PN-EN ISO 6222:2004","categories":["water"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total viable count at 36 °C","search_en":"Swimming pool water Total viable count at 36 °C Plate method, pour plate PN-EN ISO 6222:2004","technique_en":"Plate method, pour plate","test_object_en":"Swimming pool water","search_zh":"游泳池水 36 °C 微生物总数 平板法，倾注平板 PN-EN ISO 6222:2004","test_object_zh":"游泳池水","technique_zh":"平板法，倾注平板","methodology_zh":"36 °C 微生物总数"},{"_id":"6a8376e3af14b9c0e7b1f73d","lab_id":"69ad52a3de79e566650fb338","country":"PL","accr_number":"AB 626","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Liczba gronkowców koagulozododatnich","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba gronkowców koagulozododatnich\nMetoda filtracji membranowej","reference":"OL/PB-02 wydanie 2 z dnia 02.01.2020 r. W oparciu o wytyczne PZH Metodyka PZH ZHK:2007 r.","norm_bases":["OL/PB-02 wydanie 2 z dnia 02.01.2020 r. W oparciu o wytyczne PZH Metodyka PZH ZHK:2007 r."],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Higieny Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Liczba gronkowców koagulozododatnich\nMetoda filtracji membranowej OL/PB-02 wydanie 2 z dnia 02.01.2020 r. W oparciu o wytyczne PZH Metodyka PZH ZHK:2007 r. Woda na plywalniach Liczba gronkowcow koagulozododatnich\nMetoda filtracji membranowej OL/PB-02 wydanie 2 z dnia 02.01.2020 r. W oparciu o wytyczne PZH Metodyka PZH ZHK:2007 r.","categories":["water"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Count of coagulase-positive staphylococci","search_en":"Swimming pool water Count of coagulase-positive staphylococci Membrane filtration method OL/PB-02 wydanie 2 z dnia 02.01.2020 r. W oparciu o wytyczne PZH Metodyka PZH ZHK:2007 r.","technique_en":"Membrane filtration method","test_object_en":"Swimming pool water","search_zh":"游泳池水 膜过滤法 OL/PB-02 wydanie 2 z dnia 02.01.2020 r. W oparciu o wytyczne PZH Metodyka PZH ZHK:2007 r.","technique_zh":"膜过滤法","test_object_zh":"游泳池水"},{"_id":"6a8376e3af14b9c0e7b1f73e","lab_id":"69ad52a3de79e566650fb338","country":"PL","accr_number":"AB 626","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Liczba Pseudomonas aeruginosa","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PN – EN ISO 16266:2009","norm_bases":["PN – EN ISO 16266:2009"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Higieny Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN – EN ISO 16266:2009 Woda na plywalniach Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN – EN ISO 16266:2009","categories":["water"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Pseudomonas aeruginosa count","search_en":"Swimming pool water Pseudomonas aeruginosa count Membrane filtration method PN – EN ISO 16266:2009","technique_en":"Membrane filtration method","test_object_en":"Swimming pool water","methodology_zh":"铜绿假单胞菌计数","search_zh":"游泳池水 铜绿假单胞菌计数 膜过滤法 PN – EN ISO 16266:2009","technique_zh":"膜过滤法","test_object_zh":"游泳池水"},{"_id":"6a8376e3af14b9c0e7b1f73f","lab_id":"69ad52a3de79e566650fb338","country":"PL","accr_number":"AB 626","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Liczba bakterii z rodzaju Legionella, Matryca B: Procedura 7 – Podłoże C (GVPC)","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii z rodzaju Legionella, Matryca B: Procedura 7 – Podłoże C (GVPC)\nMetoda filtracji membranowej","reference":"PN-EN ISO 11731:2017-08 + Ap1:2019-12","norm_bases":["PN-EN ISO 11731:2017-08 + Ap1:2019-12"],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Higieny Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Liczba bakterii z rodzaju Legionella, Matryca B: Procedura 7 – Podłoże C (GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 + Ap1:2019-12 Woda na plywalniach Liczba bakterii z rodzaju Legionella, Matryca B: Procedura 7 – Podloze C (GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 + Ap1:2019-12","categories":["microbiology","water"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Swimming pool water Membrane filtration method PN-EN ISO 11731:2017-08 + Ap1:2019-12","technique_en":"Membrane filtration method","test_object_en":"Swimming pool water","search_zh":"游泳池水 膜过滤法 PN-EN ISO 11731:2017-08 + Ap1:2019-12","technique_zh":"膜过滤法","test_object_zh":"游泳池水"},{"_id":"6a8376e3af14b9c0e7b1f740","lab_id":"69ad52a3de79e566650fb338","country":"PL","accr_number":"AB 626","accr_body":"PCA","test_object":"Kał","methodology":"Obecność pałeczek Salmonella spp. i Shigella spp.","parameters":[],"technique":"Metoda hodowlana uzupełniona testami biochemicznymi i serologicznymi","techniques":["Metoda hodowlana uzupełniona testami biochemicznymi i serologicznymi"],"computed":[],"activity":"Obecność pałeczek Salmonella spp. i Shigella spp.\nMetoda hodowlana uzupełniona testami biochemicznymi i serologicznymi","reference":"OL/PB-03 wydanie 3 z dnia 19.11.2020 r. W oparciu o „Etiologia, obraz kliniczny i diagnostyka ostrych zakażeń i zarażeń przewodu pokarmowego oraz zatruć pokarmowych” – pod redakcją Marka Jagielskiego, Warszawa 2010 r.","norm_bases":["OL/PB-03 wydanie 3 z dnia 19.11.2020 r. W oparciu o „Etiologia, obraz kliniczny i diagnostyka ostrych zakażeń i zarażeń przewodu pokarmowego oraz zatruć pokarmowych” – pod redakcją Marka Jagielskiego, Warszawa 2010 r."],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Chorób Zakaźnych i Zakażeń","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kał Obecność pałeczek Salmonella spp. i Shigella spp.\nMetoda hodowlana uzupełniona testami biochemicznymi i serologicznymi OL/PB-03 wydanie 3 z dnia 19.11.2020 r. W oparciu o „Etiologia, obraz kliniczny i diagnostyka ostrych zakażeń i zarażeń przewodu pokarmowego oraz zatruć pokarmowych” – pod redakcją Marka Jagielskiego, Warszawa 2010 r. Kal Obecnosc paleczek Salmonella spp. i Shigella spp.\nMetoda hodowlana uzupelniona testami biochemicznymi i serologicznymi OL/PB-03 wydanie 3 z dnia 19.11.2020 r. W oparciu o „Etiologia, obraz kliniczny i diagnostyka ostrych zakazen i zarazen przewodu pokarmowego oraz zatruc pokarmowych” – pod redakcja Marka Jagielskiego, Warszawa 2010 r.","categories":["microbiology"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of Salmonella spp. and Shigella spp. rods","search_en":"Faeces Presence of Salmonella spp. and Shigella spp. rods Culture method supplemented with biochemical and serological tests OL/PB-03 wydanie 3 z dnia 19.11.2020 r. W oparciu o „Etiologia, obraz kliniczny i diagnostyka ostrych zakażeń i zarażeń przewodu pokarmowego oraz zatruć pokarmowych” – pod redakcją Marka Jagielskiego, Warszawa 2010 r.","technique_en":"Culture method supplemented with biochemical and serological tests","test_object_en":"Faeces","methodology_zh":"沙门氏菌属（Salmonella spp.）与志贺氏菌属（Shigella spp.）检出","search_zh":"粪便 沙门氏菌属（Salmonella spp.）与志贺氏菌属（Shigella spp.）检出 培养法，辅以生化与血清学试验 OL/PB-03 wydanie 3 z dnia 19.11.2020 r. W oparciu o „Etiologia, obraz kliniczny i diagnostyka ostrych zakażeń i zarażeń przewodu pokarmowego oraz zatruć pokarmowych” – pod redakcją Marka Jagielskiego, Warszawa 2010 r.","test_object_zh":"粪便","technique_zh":"培养法，辅以生化与血清学试验"},{"_id":"6a8376e3af14b9c0e7b1f741","lab_id":"69ad52a3de79e566650fb338","country":"PL","accr_number":"AB 626","accr_body":"PCA","test_object":"Kał","methodology":"Identyfikacja pałeczek Salmonella Enteritidis.","parameters":[],"technique":"Metoda serologiczna","techniques":["Metoda serologiczna"],"computed":[],"activity":"Identyfikacja pałeczek Salmonella Enteritidis.\nMetoda serologiczna","reference":"OL/PB-03 wydanie 3 z dnia 19.11.2020 r. W oparciu o „Etiologia, obraz kliniczny i diagnostyka ostrych zakażeń i zarażeń przewodu pokarmowego oraz zatruć pokarmowych” – pod redakcją Marka Jagielskiego, Warszawa 2010 r.","norm_bases":["OL/PB-03 wydanie 3 z dnia 19.11.2020 r. W oparciu o „Etiologia, obraz kliniczny i diagnostyka ostrych zakażeń i zarażeń przewodu pokarmowego oraz zatruć pokarmowych” – pod redakcją Marka Jagielskiego, Warszawa 2010 r."],"lab_section":"Oddział Laboratoryjny; Sekcja Badań Chorób Zakaźnych i Zakażeń","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kał Identyfikacja pałeczek Salmonella Enteritidis.\nMetoda serologiczna OL/PB-03 wydanie 3 z dnia 19.11.2020 r. W oparciu o „Etiologia, obraz kliniczny i diagnostyka ostrych zakażeń i zarażeń przewodu pokarmowego oraz zatruć pokarmowych” – pod redakcją Marka Jagielskiego, Warszawa 2010 r. Kal Identyfikacja paleczek Salmonella Enteritidis.\nMetoda serologiczna OL/PB-03 wydanie 3 z dnia 19.11.2020 r. W oparciu o „Etiologia, obraz kliniczny i diagnostyka ostrych zakazen i zarazen przewodu pokarmowego oraz zatruc pokarmowych” – pod redakcja Marka Jagielskiego, Warszawa 2010 r.","categories":["microbiology"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Faeces Serological method OL/PB-03 wydanie 3 z dnia 19.11.2020 r. W oparciu o „Etiologia, obraz kliniczny i diagnostyka ostrych zakażeń i zarażeń przewodu pokarmowego oraz zatruć pokarmowych” – pod redakcją Marka Jagielskiego, Warszawa 2010 r.","technique_en":"Serological method","test_object_en":"Faeces","search_zh":"粪便 血清学法 OL/PB-03 wydanie 3 z dnia 19.11.2020 r. W oparciu o „Etiologia, obraz kliniczny i diagnostyka ostrych zakażeń i zarażeń przewodu pokarmowego oraz zatruć pokarmowych” – pod redakcją Marka Jagielskiego, Warszawa 2010 r.","technique_zh":"血清学法","test_object_zh":"粪便"}],"has_pdf":true}