{"lab":{"_id":"69ad52a3de79e566650fb32c","accr_number":"AB 619","country":"PL","accr_body":"PCA","address":"im. STANISŁAWA STASZICA w KRAKOWIE, WYDZIAŁ INŻYNIERII MATERIAŁOWEJ I CERAMIKI, LABORATORIUM BADAŃ MATERIAŁÓW BUDOWLANYCH I CERAMICZNYCH, al. A. Mickiewicza 30","categories":["construction"],"city":"Kraków","imported_at":"2026-03-08T10:42:43.265Z","methods_count":29,"name":"AKADEMIA GÓRNICZO-HUTNICZA","parse_status":"parsed","parse_version":2,"pdf_files":["AB_619.pdf"],"scope_summary":"","search_text":"akademia górniczo-hutnicza im. stanisława staszica w krakowie, wydział inżynierii materiałowej i ceramiki, laboratorium badań materiałów budowlanych i ceramicznych, al. a. mickiewicza 30 construction other water","status":"active","updated_at":"2026-03-08T14:51:31.262Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-17T20:58:55.051Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20619,podmiot.html","fields_of_testing":[{"codes":"J/5","pl":"Badania mechaniczne wyrobów budowlanych","en":"Mechanical tests of building products"},{"codes":"N/5","pl":"Badania właściwości fizycznych materiałów i wyrobów budowlanych","en":"Tests of physical properties of building materials and products"}],"issue":{"no":"21","date":"05.05.2026"},"parse_date":"2026-08-17T20:58:55.051Z","parse_source":"agent-claude-code","map_coord":[50.061947,19.936856],"map_geo":"nominatim-city","lab_locations":[{"name":"LABORATORIUM BADAŃ MATERIAŁÓW BUDOWLANYCH I CERAMICZNYCH","address":"al. A. Mickiewicza 30","city":"Kraków","postal":"30-059"},{"name":"Laboratorium Badań Materiałów Budowlanych i Ceramicznych","address":"Al. A. Mickiewicza 30","city":"Kraków","postal":"30-059"}],"scope_format":"PCA::pracownie+siatka5","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/c6c07350104ec12bea0d10eccf241dda/AB%20619.pdf","has_en":true,"category_counts":{"construction":24,"other":4,"water":1},"category_scores":{"construction":19.86,"other":0.55,"water":0.03},"has_zh":true},"methods":[{"_id":"6a83760faf14b9c0e7b1f64f","lab_id":"69ad52a3de79e566650fb32c","country":"PL","accr_number":"AB 619","accr_body":"PCA","test_object":"Beton","methodology":"Wytrzymałość na ściskanie","parameters":[{"name":"Zakres","range":"(5-3000) kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na ściskanie\nZakres (5-3000) kN","reference":"PN-EN 12390-3:2019-07","norm_bases":["PN-EN 12390-3:2019-07"],"lab_section":"Laboratorium Badań Materiałów Budowlanych i Ceramicznych; Al. A. Mickiewicza 30, 30-059 Kraków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Wytrzymałość na ściskanie\nZakres (5-3000) kN PN-EN 12390-3:2019-07 Beton Wytrzymalosc na sciskanie\nZakres (5-3000) kN PN-EN 12390-3:2019-07","categories":["construction"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Compressive strength","parameters_en":[{"name":"Range","range":"(5-3000) kN"}],"search_en":"Concrete Compressive strength Range PN-EN 12390-3:2019-07","test_object_en":"Concrete","methodology_zh":"抗压强度","parameters_zh":[{"name":"范围","range":"(5-3000) kN"}],"search_zh":"混凝土 抗压强度 范围 PN-EN 12390-3:2019-07","test_object_zh":"混凝土"},{"_id":"6a83760faf14b9c0e7b1f650","lab_id":"69ad52a3de79e566650fb32c","country":"PL","accr_number":"AB 619","accr_body":"PCA","test_object":"Beton","methodology":"Wytrzymałość na zginanie","parameters":[{"name":"Zakres","range":"(3-150) kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na zginanie\nZakres (3-150) kN","reference":"PN-EN 12390-5:2019-08","norm_bases":["PN-EN 12390-5:2019-08"],"lab_section":"Laboratorium Badań Materiałów Budowlanych i Ceramicznych; Al. A. Mickiewicza 30, 30-059 Kraków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Wytrzymałość na zginanie\nZakres (3-150) kN PN-EN 12390-5:2019-08 Beton Wytrzymalosc na zginanie\nZakres (3-150) kN PN-EN 12390-5:2019-08","categories":["construction"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Flexural strength","parameters_en":[{"name":"Range","range":"(3-150) kN"}],"search_en":"Concrete Flexural strength Range PN-EN 12390-5:2019-08","test_object_en":"Concrete","parameters_zh":[{"name":"范围","range":"(3-150) kN"}],"search_zh":"混凝土 抗弯强度 范围 PN-EN 12390-5:2019-08","test_object_zh":"混凝土","methodology_zh":"抗弯强度"},{"_id":"6a83760faf14b9c0e7b1f651","lab_id":"69ad52a3de79e566650fb32c","country":"PL","accr_number":"AB 619","accr_body":"PCA","test_object":"Beton","methodology":"Nasiąkliwość","parameters":[],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Nasiąkliwość\nMetoda wagowa","reference":"PN-88/B-06250","norm_bases":["PN-88/B-06250"],"lab_section":"Laboratorium Badań Materiałów Budowlanych i Ceramicznych; Al. A. Mickiewicza 30, 30-059 Kraków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Nasiąkliwość\nMetoda wagowa PN-88/B-06250 Beton Nasiakliwosc\nMetoda wagowa PN-88/B-06250","categories":["construction"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water absorption","search_en":"Concrete Water absorption Gravimetric method PN-88/B-06250","technique_en":"Gravimetric method","test_object_en":"Concrete","methodology_zh":"吸水率","search_zh":"混凝土 吸水率 重量法 PN-88/B-06250","technique_zh":"重量法","test_object_zh":"混凝土"},{"_id":"6a83760faf14b9c0e7b1f652","lab_id":"69ad52a3de79e566650fb32c","country":"PL","accr_number":"AB 619","accr_body":"PCA","test_object":"Beton","methodology":"Gęstość","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Gęstość","reference":"PN-EN 12390-7:2019-08","norm_bases":["PN-EN 12390-7:2019-08"],"lab_section":"Laboratorium Badań Materiałów Budowlanych i Ceramicznych; Al. A. Mickiewicza 30, 30-059 Kraków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Gęstość PN-EN 12390-7:2019-08 Beton Gestosc PN-EN 12390-7:2019-08","categories":["construction"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Density","search_en":"Concrete Density PN-EN 12390-7:2019-08","test_object_en":"Concrete","methodology_zh":"密度","search_zh":"混凝土 密度 PN-EN 12390-7:2019-08","test_object_zh":"混凝土"},{"_id":"6a83760faf14b9c0e7b1f653","lab_id":"69ad52a3de79e566650fb32c","country":"PL","accr_number":"AB 619","accr_body":"PCA","test_object":"Beton","methodology":"Odporność na działanie mrozu","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na działanie mrozu","reference":"PN-88/B-06250 | PN-B-06265:2022-08 Załącznik N | PN-B-06265:2022-8/Az1:2025-08 Załącznik N","norm_bases":["PN-88/B-06250","PN-B-06265:2022-08 Załącznik N","PN-B-06265:2022-8/Az1:2025-08 Załącznik N"],"lab_section":"Laboratorium Badań Materiałów Budowlanych i Ceramicznych; Al. A. Mickiewicza 30, 30-059 Kraków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Odporność na działanie mrozu PN-88/B-06250 | PN-B-06265:2022-08 Załącznik N | PN-B-06265:2022-8/Az1:2025-08 Załącznik N Beton Odpornosc na dzialanie mrozu PN-88/B-06250 | PN-B-06265:2022-08 Zalacznik N | PN-B-06265:2022-8/Az1:2025-08 Zalacznik N","categories":["construction"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Resistance to freezing","search_en":"Concrete Resistance to freezing PN-88/B-06250 | PN-B-06265:2022-08 Załącznik N | PN-B-06265:2022-8/Az1:2025-08 Załącznik N","test_object_en":"Concrete","methodology_zh":"抗冻性","search_zh":"混凝土 抗冻性 PN-88/B-06250 | PN-B-06265:2022-08 Załącznik N | PN-B-06265:2022-8/Az1:2025-08 Załącznik N","test_object_zh":"混凝土"},{"_id":"6a83760faf14b9c0e7b1f654","lab_id":"69ad52a3de79e566650fb32c","country":"PL","accr_number":"AB 619","accr_body":"PCA","test_object":"Beton","methodology":"Odporność na zamrażanie i rozmrażanie w obecności soli odladzających","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na zamrażanie i rozmrażanie w obecności soli odladzających","reference":"PKN-CEN/TS 12390-9:2017-07 | PN-B-06265:2022-08 Załącznik O | PN-B-06265:2022-08 /Az1:2025-08 Załącznik O","norm_bases":["PKN-CEN/TS 12390-9:2017-07","PN-B-06265:2022-08 Załącznik O","PN-B-06265:2022-08 /Az1:2025-08 Załącznik O"],"lab_section":"Laboratorium Badań Materiałów Budowlanych i Ceramicznych; Al. A. Mickiewicza 30, 30-059 Kraków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Odporność na zamrażanie i rozmrażanie w obecności soli odladzających PKN-CEN/TS 12390-9:2017-07 | PN-B-06265:2022-08 Załącznik O | PN-B-06265:2022-08 /Az1:2025-08 Załącznik O Beton Odpornosc na zamrazanie i rozmrazanie w obecnosci soli odladzajacych PKN-CEN/TS 12390-9:2017-07 | PN-B-06265:2022-08 Zalacznik O | PN-B-06265:2022-08 /Az1:2025-08 Zalacznik O","categories":["construction"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Freeze-thaw resistance in the presence of de-icing salts","search_en":"Concrete Freeze-thaw resistance in the presence of de-icing salts PKN-CEN/TS 12390-9:2017-07 | PN-B-06265:2022-08 Załącznik O | PN-B-06265:2022-08 /Az1:2025-08 Załącznik O","test_object_en":"Concrete","search_zh":"混凝土 含除冰盐的抗冻融性 PKN-CEN/TS 12390-9:2017-07 | PN-B-06265:2022-08 Załącznik O | PN-B-06265:2022-08 /Az1:2025-08 Załącznik O","test_object_zh":"混凝土","methodology_zh":"含除冰盐的抗冻融性"},{"_id":"6a83760faf14b9c0e7b1f655","lab_id":"69ad52a3de79e566650fb32c","country":"PL","accr_number":"AB 619","accr_body":"PCA","test_object":"Betonowe kostki brukowe","methodology":"Wygląd zewnętrzny","parameters":[],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Wygląd zewnętrzny\nMetoda wizualna","reference":"PN-EN 1338:2005 | PN-EN 1338:2005/AC:2007","norm_bases":["PN-EN 1338:2005","PN-EN 1338:2005/AC:2007"],"lab_section":"Laboratorium Badań Materiałów Budowlanych i Ceramicznych; Al. A. Mickiewicza 30, 30-059 Kraków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Betonowe kostki brukowe Wygląd zewnętrzny\nMetoda wizualna PN-EN 1338:2005 | PN-EN 1338:2005/AC:2007 Betonowe kostki brukowe Wyglad zewnetrzny\nMetoda wizualna PN-EN 1338:2005 | PN-EN 1338:2005/AC:2007","categories":["construction"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"External appearance","search_en":"Concrete paving blocks External appearance Visual method PN-EN 1338:2005 | PN-EN 1338:2005/AC:2007","technique_en":"Visual method","test_object_en":"Concrete paving blocks","search_zh":"混凝土铺路砖 外观 目视法 PN-EN 1338:2005 | PN-EN 1338:2005/AC:2007","technique_zh":"目视法","test_object_zh":"混凝土铺路砖","methodology_zh":"外观"},{"_id":"6a83760faf14b9c0e7b1f656","lab_id":"69ad52a3de79e566650fb32c","country":"PL","accr_number":"AB 619","accr_body":"PCA","test_object":"Betonowe kostki brukowe","methodology":"Wymiary","parameters":[{"name":"Zakres","range":"do 1100 mm"}],"technique":null,"techniques":[],"computed":[],"activity":"Wymiary\nZakres do 1100 mm","reference":"PN-EN 1338:2005 | PN-EN 1338:2005/AC:2007","norm_bases":["PN-EN 1338:2005","PN-EN 1338:2005/AC:2007"],"lab_section":"Laboratorium Badań Materiałów Budowlanych i Ceramicznych; Al. A. Mickiewicza 30, 30-059 Kraków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Betonowe kostki brukowe Wymiary\nZakres do 1100 mm PN-EN 1338:2005 | PN-EN 1338:2005/AC:2007 Betonowe kostki brukowe Wymiary\nZakres do 1100 mm PN-EN 1338:2005 | PN-EN 1338:2005/AC:2007","categories":["construction"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dimensions","parameters_en":[{"name":"Range","range":"do 1100 mm"}],"search_en":"Concrete paving blocks Dimensions Range PN-EN 1338:2005 | PN-EN 1338:2005/AC:2007","test_object_en":"Concrete paving blocks","parameters_zh":[{"name":"范围","range":"do 1100 mm"}],"search_zh":"混凝土铺路砖 尺寸 范围 PN-EN 1338:2005 | PN-EN 1338:2005/AC:2007","methodology_zh":"尺寸","test_object_zh":"混凝土铺路砖"},{"_id":"6a83760faf14b9c0e7b1f657","lab_id":"69ad52a3de79e566650fb32c","country":"PL","accr_number":"AB 619","accr_body":"PCA","test_object":"Betonowe kostki brukowe","methodology":"Nasiąkliwość","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Nasiąkliwość","reference":"PN-EN 1338:2005 | PN-EN 1338:2005/AC:2007","norm_bases":["PN-EN 1338:2005","PN-EN 1338:2005/AC:2007"],"lab_section":"Laboratorium Badań Materiałów Budowlanych i Ceramicznych; Al. A. Mickiewicza 30, 30-059 Kraków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Betonowe kostki brukowe Nasiąkliwość PN-EN 1338:2005 | PN-EN 1338:2005/AC:2007 Betonowe kostki brukowe Nasiakliwosc PN-EN 1338:2005 | PN-EN 1338:2005/AC:2007","categories":["construction"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water absorption","search_en":"Concrete paving blocks Water absorption PN-EN 1338:2005 | PN-EN 1338:2005/AC:2007","test_object_en":"Concrete paving blocks","methodology_zh":"吸水率","search_zh":"混凝土铺路砖 吸水率 PN-EN 1338:2005 | PN-EN 1338:2005/AC:2007","test_object_zh":"混凝土铺路砖"},{"_id":"6a83760faf14b9c0e7b1f658","lab_id":"69ad52a3de79e566650fb32c","country":"PL","accr_number":"AB 619","accr_body":"PCA","test_object":"Betonowe kostki brukowe","methodology":"Wytrzymałość na rozciąganie przy rozłupywaniu","parameters":[{"name":"Zakres","range":"(10-3000) kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na rozciąganie przy rozłupywaniu\nZakres (10-3000) kN","reference":"PN-EN 1338:2005 | PN-EN 1338:2005/AC:2007","norm_bases":["PN-EN 1338:2005","PN-EN 1338:2005/AC:2007"],"lab_section":"Laboratorium Badań Materiałów Budowlanych i Ceramicznych; Al. A. Mickiewicza 30, 30-059 Kraków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Betonowe kostki brukowe Wytrzymałość na rozciąganie przy rozłupywaniu\nZakres (10-3000) kN PN-EN 1338:2005 | PN-EN 1338:2005/AC:2007 Betonowe kostki brukowe Wytrzymalosc na rozciaganie przy rozlupywaniu\nZakres (10-3000) kN PN-EN 1338:2005 | PN-EN 1338:2005/AC:2007","categories":["construction"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Splitting tensile strength","parameters_en":[{"name":"Range","range":"(10-3000) kN"}],"search_en":"Concrete paving blocks Splitting tensile strength Range PN-EN 1338:2005 | PN-EN 1338:2005/AC:2007","test_object_en":"Concrete paving blocks","methodology_zh":"劈裂抗拉强度","parameters_zh":[{"name":"范围","range":"(10-3000) kN"}],"search_zh":"混凝土铺路砖 劈裂抗拉强度 范围 PN-EN 1338:2005 | PN-EN 1338:2005/AC:2007","test_object_zh":"混凝土铺路砖"},{"_id":"6a83760faf14b9c0e7b1f659","lab_id":"69ad52a3de79e566650fb32c","country":"PL","accr_number":"AB 619","accr_body":"PCA","test_object":"Betonowe kostki brukowe","methodology":"Odporność na zamrażanie-rozmrażanie z udziałem soli odladzającej","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na zamrażanie-rozmrażanie z udziałem soli odladzającej","reference":"PN-EN 1338:2005 | PN-EN 1338:2005/AC:2007","norm_bases":["PN-EN 1338:2005","PN-EN 1338:2005/AC:2007"],"lab_section":"Laboratorium Badań Materiałów Budowlanych i Ceramicznych; Al. A. Mickiewicza 30, 30-059 Kraków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Betonowe kostki brukowe Odporność na zamrażanie-rozmrażanie z udziałem soli odladzającej PN-EN 1338:2005 | PN-EN 1338:2005/AC:2007 Betonowe kostki brukowe Odpornosc na zamrazanie-rozmrazanie z udzialem soli odladzajacej PN-EN 1338:2005 | PN-EN 1338:2005/AC:2007","categories":["construction"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Concrete paving blocks PN-EN 1338:2005 | PN-EN 1338:2005/AC:2007","test_object_en":"Concrete paving blocks","search_zh":"混凝土铺路砖 PN-EN 1338:2005 | PN-EN 1338:2005/AC:2007","test_object_zh":"混凝土铺路砖"},{"_id":"6a83760faf14b9c0e7b1f65a","lab_id":"69ad52a3de79e566650fb32c","country":"PL","accr_number":"AB 619","accr_body":"PCA","test_object":"Betonowe kostki brukowe","methodology":"Odporność na ścieranie","parameters":[],"technique":"Metoda szerokiej tarczy ściernej","techniques":["Metoda szerokiej tarczy ściernej"],"computed":[],"activity":"Odporność na ścieranie\nMetoda szerokiej tarczy ściernej","reference":"PN-EN 1338:2005 | PN-EN 1338:2005/AC:2007","norm_bases":["PN-EN 1338:2005","PN-EN 1338:2005/AC:2007"],"lab_section":"Laboratorium Badań Materiałów Budowlanych i Ceramicznych; Al. A. Mickiewicza 30, 30-059 Kraków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Betonowe kostki brukowe Odporność na ścieranie\nMetoda szerokiej tarczy ściernej PN-EN 1338:2005 | PN-EN 1338:2005/AC:2007 Betonowe kostki brukowe Odpornosc na scieranie\nMetoda szerokiej tarczy sciernej PN-EN 1338:2005 | PN-EN 1338:2005/AC:2007","categories":["construction"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Abrasion resistance","search_en":"Concrete paving blocks Abrasion resistance Wide abrasive wheel method PN-EN 1338:2005 | PN-EN 1338:2005/AC:2007","technique_en":"Wide abrasive wheel method","test_object_en":"Concrete paving blocks","methodology_zh":"耐磨性","search_zh":"混凝土铺路砖 耐磨性 PN-EN 1338:2005 | PN-EN 1338:2005/AC:2007","test_object_zh":"混凝土铺路砖"},{"_id":"6a83760faf14b9c0e7b1f65b","lab_id":"69ad52a3de79e566650fb32c","country":"PL","accr_number":"AB 619","accr_body":"PCA","test_object":"Betonowe płyty brukowe","methodology":"Wygląd zewnętrzny","parameters":[],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Wygląd zewnętrzny\nMetoda wizualna","reference":"PN-EN 1339:2005 | PN-EN 1339:2005/AC:2007","norm_bases":["PN-EN 1339:2005","PN-EN 1339:2005/AC:2007"],"lab_section":"Laboratorium Badań Materiałów Budowlanych i Ceramicznych; Al. A. Mickiewicza 30, 30-059 Kraków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Betonowe płyty brukowe Wygląd zewnętrzny\nMetoda wizualna PN-EN 1339:2005 | PN-EN 1339:2005/AC:2007 Betonowe plyty brukowe Wyglad zewnetrzny\nMetoda wizualna PN-EN 1339:2005 | PN-EN 1339:2005/AC:2007","categories":["construction"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"External appearance","search_en":"Concrete paving flags External appearance Visual method PN-EN 1339:2005 | PN-EN 1339:2005/AC:2007","technique_en":"Visual method","test_object_en":"Concrete paving flags","search_zh":"混凝土路面砖 外观 目视法 PN-EN 1339:2005 | PN-EN 1339:2005/AC:2007","technique_zh":"目视法","test_object_zh":"混凝土路面砖","methodology_zh":"外观"},{"_id":"6a83760faf14b9c0e7b1f65c","lab_id":"69ad52a3de79e566650fb32c","country":"PL","accr_number":"AB 619","accr_body":"PCA","test_object":"Betonowe płyty brukowe","methodology":"Wymiary","parameters":[{"name":"Zakres","range":"do 1100 mm"}],"technique":null,"techniques":[],"computed":[],"activity":"Wymiary\nZakres do 1100 mm","reference":"PN-EN 1339:2005 | PN-EN 1339:2005/AC:2007","norm_bases":["PN-EN 1339:2005","PN-EN 1339:2005/AC:2007"],"lab_section":"Laboratorium Badań Materiałów Budowlanych i Ceramicznych; Al. A. Mickiewicza 30, 30-059 Kraków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Betonowe płyty brukowe Wymiary\nZakres do 1100 mm PN-EN 1339:2005 | PN-EN 1339:2005/AC:2007 Betonowe plyty brukowe Wymiary\nZakres do 1100 mm PN-EN 1339:2005 | PN-EN 1339:2005/AC:2007","categories":["construction"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dimensions","parameters_en":[{"name":"Range","range":"do 1100 mm"}],"search_en":"Concrete paving flags Dimensions Range PN-EN 1339:2005 | PN-EN 1339:2005/AC:2007","test_object_en":"Concrete paving flags","parameters_zh":[{"name":"范围","range":"do 1100 mm"}],"search_zh":"混凝土路面砖 尺寸 范围 PN-EN 1339:2005 | PN-EN 1339:2005/AC:2007","methodology_zh":"尺寸","test_object_zh":"混凝土路面砖"},{"_id":"6a83760faf14b9c0e7b1f65d","lab_id":"69ad52a3de79e566650fb32c","country":"PL","accr_number":"AB 619","accr_body":"PCA","test_object":"Betonowe płyty brukowe","methodology":"Nasiąkliwość","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Nasiąkliwość","reference":"PN-EN 1339:2005 | PN-EN 1339:2005/AC:2007","norm_bases":["PN-EN 1339:2005","PN-EN 1339:2005/AC:2007"],"lab_section":"Laboratorium Badań Materiałów Budowlanych i Ceramicznych; Al. A. Mickiewicza 30, 30-059 Kraków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Betonowe płyty brukowe Nasiąkliwość PN-EN 1339:2005 | PN-EN 1339:2005/AC:2007 Betonowe plyty brukowe Nasiakliwosc PN-EN 1339:2005 | PN-EN 1339:2005/AC:2007","categories":["construction"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water absorption","search_en":"Concrete paving flags Water absorption PN-EN 1339:2005 | PN-EN 1339:2005/AC:2007","test_object_en":"Concrete paving flags","methodology_zh":"吸水率","search_zh":"混凝土路面砖 吸水率 PN-EN 1339:2005 | PN-EN 1339:2005/AC:2007","test_object_zh":"混凝土路面砖"},{"_id":"6a83760faf14b9c0e7b1f65e","lab_id":"69ad52a3de79e566650fb32c","country":"PL","accr_number":"AB 619","accr_body":"PCA","test_object":"Betonowe płyty brukowe","methodology":"Wytrzymałość na zginanie","parameters":[{"name":"Zakres","range":"(3-150) kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na zginanie\nZakres (3-150) kN","reference":"PN-EN 1339:2005 | PN-EN 1339:2005/AC:2007","norm_bases":["PN-EN 1339:2005","PN-EN 1339:2005/AC:2007"],"lab_section":"Laboratorium Badań Materiałów Budowlanych i Ceramicznych; Al. A. Mickiewicza 30, 30-059 Kraków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Betonowe płyty brukowe Wytrzymałość na zginanie\nZakres (3-150) kN PN-EN 1339:2005 | PN-EN 1339:2005/AC:2007 Betonowe plyty brukowe Wytrzymalosc na zginanie\nZakres (3-150) kN PN-EN 1339:2005 | PN-EN 1339:2005/AC:2007","categories":["construction"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Flexural strength","parameters_en":[{"name":"Range","range":"(3-150) kN"}],"search_en":"Concrete paving flags Flexural strength Range PN-EN 1339:2005 | PN-EN 1339:2005/AC:2007","test_object_en":"Concrete paving flags","parameters_zh":[{"name":"范围","range":"(3-150) kN"}],"search_zh":"混凝土路面砖 抗弯强度 范围 PN-EN 1339:2005 | PN-EN 1339:2005/AC:2007","methodology_zh":"抗弯强度","test_object_zh":"混凝土路面砖"},{"_id":"6a83760faf14b9c0e7b1f65f","lab_id":"69ad52a3de79e566650fb32c","country":"PL","accr_number":"AB 619","accr_body":"PCA","test_object":"Betonowe płyty brukowe","methodology":"Odporność na zamrażanie-rozmrażanie z udziałem soli odladzającej","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na zamrażanie-rozmrażanie z udziałem soli odladzającej","reference":"PN-EN 1339:2005 | PN-EN 1339:2005/AC:2007","norm_bases":["PN-EN 1339:2005","PN-EN 1339:2005/AC:2007"],"lab_section":"Laboratorium Badań Materiałów Budowlanych i Ceramicznych; Al. A. Mickiewicza 30, 30-059 Kraków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Betonowe płyty brukowe Odporność na zamrażanie-rozmrażanie z udziałem soli odladzającej PN-EN 1339:2005 | PN-EN 1339:2005/AC:2007 Betonowe plyty brukowe Odpornosc na zamrazanie-rozmrazanie z udzialem soli odladzajacej PN-EN 1339:2005 | PN-EN 1339:2005/AC:2007","categories":["construction"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Concrete paving flags PN-EN 1339:2005 | PN-EN 1339:2005/AC:2007","test_object_en":"Concrete paving flags","search_zh":"混凝土路面砖 PN-EN 1339:2005 | PN-EN 1339:2005/AC:2007","test_object_zh":"混凝土路面砖"},{"_id":"6a83760faf14b9c0e7b1f660","lab_id":"69ad52a3de79e566650fb32c","country":"PL","accr_number":"AB 619","accr_body":"PCA","test_object":"Betonowe płyty brukowe","methodology":"Odporność na ścieranie","parameters":[],"technique":"Metoda szerokiej tarczy ściernej","techniques":["Metoda szerokiej tarczy ściernej"],"computed":[],"activity":"Odporność na ścieranie\nMetoda szerokiej tarczy ściernej","reference":"PN-EN 1339:2005 | PN-EN 1339:2005/AC:2007","norm_bases":["PN-EN 1339:2005","PN-EN 1339:2005/AC:2007"],"lab_section":"Laboratorium Badań Materiałów Budowlanych i Ceramicznych; Al. A. Mickiewicza 30, 30-059 Kraków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Betonowe płyty brukowe Odporność na ścieranie\nMetoda szerokiej tarczy ściernej PN-EN 1339:2005 | PN-EN 1339:2005/AC:2007 Betonowe plyty brukowe Odpornosc na scieranie\nMetoda szerokiej tarczy sciernej PN-EN 1339:2005 | PN-EN 1339:2005/AC:2007","categories":["construction"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Abrasion resistance","search_en":"Concrete paving flags Abrasion resistance Wide abrasive wheel method PN-EN 1339:2005 | PN-EN 1339:2005/AC:2007","technique_en":"Wide abrasive wheel method","test_object_en":"Concrete paving flags","methodology_zh":"耐磨性","search_zh":"混凝土路面砖 耐磨性 PN-EN 1339:2005 | PN-EN 1339:2005/AC:2007","test_object_zh":"混凝土路面砖"},{"_id":"6a83760faf14b9c0e7b1f661","lab_id":"69ad52a3de79e566650fb32c","country":"PL","accr_number":"AB 619","accr_body":"PCA","test_object":"Krawężniki i obrzeża betonowe","methodology":"Wygląd zewnętrzny","parameters":[],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Wygląd zewnętrzny\nMetoda wizualna","reference":"PN-EN 1340:2004 | PN-EN 1340:2004/AC:2007","norm_bases":["PN-EN 1340:2004","PN-EN 1340:2004/AC:2007"],"lab_section":"Laboratorium Badań Materiałów Budowlanych i Ceramicznych; Al. A. Mickiewicza 30, 30-059 Kraków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Krawężniki i obrzeża betonowe Wygląd zewnętrzny\nMetoda wizualna PN-EN 1340:2004 | PN-EN 1340:2004/AC:2007 Krawezniki i obrzeza betonowe Wyglad zewnetrzny\nMetoda wizualna PN-EN 1340:2004 | PN-EN 1340:2004/AC:2007","categories":["construction"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"External appearance","search_en":"Concrete kerb units and edgings External appearance Visual method PN-EN 1340:2004 | PN-EN 1340:2004/AC:2007","technique_en":"Visual method","test_object_en":"Concrete kerb units and edgings","search_zh":"混凝土路缘石与边石 外观 目视法 PN-EN 1340:2004 | PN-EN 1340:2004/AC:2007","technique_zh":"目视法","methodology_zh":"外观","test_object_zh":"混凝土路缘石与边石"},{"_id":"6a83760faf14b9c0e7b1f662","lab_id":"69ad52a3de79e566650fb32c","country":"PL","accr_number":"AB 619","accr_body":"PCA","test_object":"Krawężniki i obrzeża betonowe","methodology":"Wymiary","parameters":[{"name":"Zakres","range":"do 1100 mm"}],"technique":null,"techniques":[],"computed":[],"activity":"Wymiary\nZakres do 1100 mm","reference":"PN-EN 1340:2004 | PN-EN 1340:2004/AC:2007","norm_bases":["PN-EN 1340:2004","PN-EN 1340:2004/AC:2007"],"lab_section":"Laboratorium Badań Materiałów Budowlanych i Ceramicznych; Al. A. Mickiewicza 30, 30-059 Kraków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Krawężniki i obrzeża betonowe Wymiary\nZakres do 1100 mm PN-EN 1340:2004 | PN-EN 1340:2004/AC:2007 Krawezniki i obrzeza betonowe Wymiary\nZakres do 1100 mm PN-EN 1340:2004 | PN-EN 1340:2004/AC:2007","categories":["construction"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dimensions","parameters_en":[{"name":"Range","range":"do 1100 mm"}],"search_en":"Concrete kerb units and edgings Dimensions Range PN-EN 1340:2004 | PN-EN 1340:2004/AC:2007","test_object_en":"Concrete kerb units and edgings","parameters_zh":[{"name":"范围","range":"do 1100 mm"}],"search_zh":"混凝土路缘石与边石 尺寸 范围 PN-EN 1340:2004 | PN-EN 1340:2004/AC:2007","methodology_zh":"尺寸","test_object_zh":"混凝土路缘石与边石"},{"_id":"6a83760faf14b9c0e7b1f663","lab_id":"69ad52a3de79e566650fb32c","country":"PL","accr_number":"AB 619","accr_body":"PCA","test_object":"Krawężniki i obrzeża betonowe","methodology":"Nasiąkliwość","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Nasiąkliwość","reference":"PN-EN 1340:2004 | PN-EN 1340:2004/AC:2007","norm_bases":["PN-EN 1340:2004","PN-EN 1340:2004/AC:2007"],"lab_section":"Laboratorium Badań Materiałów Budowlanych i Ceramicznych; Al. A. Mickiewicza 30, 30-059 Kraków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Krawężniki i obrzeża betonowe Nasiąkliwość PN-EN 1340:2004 | PN-EN 1340:2004/AC:2007 Krawezniki i obrzeza betonowe Nasiakliwosc PN-EN 1340:2004 | PN-EN 1340:2004/AC:2007","categories":["construction"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water absorption","search_en":"Concrete kerb units and edgings Water absorption PN-EN 1340:2004 | PN-EN 1340:2004/AC:2007","test_object_en":"Concrete kerb units and edgings","methodology_zh":"吸水率","search_zh":"混凝土路缘石与边石 吸水率 PN-EN 1340:2004 | PN-EN 1340:2004/AC:2007","test_object_zh":"混凝土路缘石与边石"},{"_id":"6a83760faf14b9c0e7b1f664","lab_id":"69ad52a3de79e566650fb32c","country":"PL","accr_number":"AB 619","accr_body":"PCA","test_object":"Krawężniki i obrzeża betonowe","methodology":"Wytrzymałość na zginanie","parameters":[{"name":"Zakres","range":"(3-150) kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na zginanie\nZakres (3-150) kN","reference":"PN-EN 1340:2004 | PN-EN 1340:2004/AC:2007","norm_bases":["PN-EN 1340:2004","PN-EN 1340:2004/AC:2007"],"lab_section":"Laboratorium Badań Materiałów Budowlanych i Ceramicznych; Al. A. Mickiewicza 30, 30-059 Kraków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Krawężniki i obrzeża betonowe Wytrzymałość na zginanie\nZakres (3-150) kN PN-EN 1340:2004 | PN-EN 1340:2004/AC:2007 Krawezniki i obrzeza betonowe Wytrzymalosc na zginanie\nZakres (3-150) kN PN-EN 1340:2004 | PN-EN 1340:2004/AC:2007","categories":["construction"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Flexural strength","parameters_en":[{"name":"Range","range":"(3-150) kN"}],"search_en":"Concrete kerb units and edgings Flexural strength Range PN-EN 1340:2004 | PN-EN 1340:2004/AC:2007","test_object_en":"Concrete kerb units and edgings","parameters_zh":[{"name":"范围","range":"(3-150) kN"}],"search_zh":"混凝土路缘石与边石 抗弯强度 范围 PN-EN 1340:2004 | PN-EN 1340:2004/AC:2007","methodology_zh":"抗弯强度","test_object_zh":"混凝土路缘石与边石"},{"_id":"6a83760faf14b9c0e7b1f665","lab_id":"69ad52a3de79e566650fb32c","country":"PL","accr_number":"AB 619","accr_body":"PCA","test_object":"Krawężniki i obrzeża betonowe","methodology":"Odporność na zamrażanie-rozmrażanie z udziałem soli odladzającej","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na zamrażanie-rozmrażanie z udziałem soli odladzającej","reference":"PN-EN 1340:2004 | PN-EN 1340:2004/AC:2007","norm_bases":["PN-EN 1340:2004","PN-EN 1340:2004/AC:2007"],"lab_section":"Laboratorium Badań Materiałów Budowlanych i Ceramicznych; Al. A. Mickiewicza 30, 30-059 Kraków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Krawężniki i obrzeża betonowe Odporność na zamrażanie-rozmrażanie z udziałem soli odladzającej PN-EN 1340:2004 | PN-EN 1340:2004/AC:2007 Krawezniki i obrzeza betonowe Odpornosc na zamrazanie-rozmrazanie z udzialem soli odladzajacej PN-EN 1340:2004 | PN-EN 1340:2004/AC:2007","categories":["construction"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Concrete kerb units and edgings PN-EN 1340:2004 | PN-EN 1340:2004/AC:2007","test_object_en":"Concrete kerb units and edgings","search_zh":"混凝土路缘石与边石 PN-EN 1340:2004 | PN-EN 1340:2004/AC:2007","test_object_zh":"混凝土路缘石与边石"},{"_id":"6a83760faf14b9c0e7b1f666","lab_id":"69ad52a3de79e566650fb32c","country":"PL","accr_number":"AB 619","accr_body":"PCA","test_object":"Krawężniki i obrzeża betonowe","methodology":"Odporność na ścieranie","parameters":[],"technique":"Metoda szerokiej tarczy ściernej","techniques":["Metoda szerokiej tarczy ściernej"],"computed":[],"activity":"Odporność na ścieranie\nMetoda szerokiej tarczy ściernej","reference":"PN-EN 1340:2004 | PN-EN 1340:2004/AC:2007","norm_bases":["PN-EN 1340:2004","PN-EN 1340:2004/AC:2007"],"lab_section":"Laboratorium Badań Materiałów Budowlanych i Ceramicznych; Al. A. Mickiewicza 30, 30-059 Kraków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Krawężniki i obrzeża betonowe Odporność na ścieranie\nMetoda szerokiej tarczy ściernej PN-EN 1340:2004 | PN-EN 1340:2004/AC:2007 Krawezniki i obrzeza betonowe Odpornosc na scieranie\nMetoda szerokiej tarczy sciernej PN-EN 1340:2004 | PN-EN 1340:2004/AC:2007","categories":["construction"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Abrasion resistance","search_en":"Concrete kerb units and edgings Abrasion resistance Wide abrasive wheel method PN-EN 1340:2004 | PN-EN 1340:2004/AC:2007","technique_en":"Wide abrasive wheel method","test_object_en":"Concrete kerb units and edgings","methodology_zh":"耐磨性","search_zh":"混凝土路缘石与边石 耐磨性 PN-EN 1340:2004 | PN-EN 1340:2004/AC:2007","test_object_zh":"混凝土路缘石与边石"},{"_id":"6a83760faf14b9c0e7b1f667","lab_id":"69ad52a3de79e566650fb32c","country":"PL","accr_number":"AB 619","accr_body":"PCA","test_object":"Elementy murowe","methodology":"Wytrzymałość na ściskanie","parameters":[{"name":"Zakres","range":"(10-3000) kN"},{"name":"Próbka max. wym.","range":"500x310x345 mm"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na ściskanie\nZakres:\nZakres (10-3000) kN\nPróbka max. wym. 500x310x345 mm","reference":"PN-EN 772-1+A1:2015-10","norm_bases":["PN-EN 772-1+A1:2015-10"],"lab_section":"Laboratorium Badań Materiałów Budowlanych i Ceramicznych; Al. A. Mickiewicza 30, 30-059 Kraków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elementy murowe Wytrzymałość na ściskanie\nZakres:\nZakres (10-3000) kN\nPróbka max. wym. 500x310x345 mm PN-EN 772-1+A1:2015-10 Elementy murowe Wytrzymalosc na sciskanie\nZakres:\nZakres (10-3000) kN\nProbka max. wym. 500x310x345 mm PN-EN 772-1+A1:2015-10","categories":["other"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Compressive strength","parameters_en":[{"name":"Range","range":"(10-3000) kN"},{"name":"Próbka max. wym.","range":"500x310x345 mm"}],"search_en":"Masonry units Compressive strength Range PN-EN 772-1+A1:2015-10","test_object_en":"Masonry units","methodology_zh":"抗压强度","parameters_zh":[{"name":"范围","range":"(10-3000) kN"},{"name":"Próbka max. wym.","range":"500x310x345 mm"}],"search_zh":"砌块 抗压强度 范围 PN-EN 772-1+A1:2015-10","test_object_zh":"砌块"},{"_id":"6a83760faf14b9c0e7b1f668","lab_id":"69ad52a3de79e566650fb32c","country":"PL","accr_number":"AB 619","accr_body":"PCA","test_object":"Elementy murowe","methodology":"Gęstość netto i gęstość brutto w stanie suchym (z wyjątkiem kamienia naturalnego)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Gęstość netto i gęstość brutto w stanie suchym (z wyjątkiem kamienia naturalnego)","reference":"PN-EN 772-13:2001","norm_bases":["PN-EN 772-13:2001"],"lab_section":"Laboratorium Badań Materiałów Budowlanych i Ceramicznych; Al. A. Mickiewicza 30, 30-059 Kraków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elementy murowe Gęstość netto i gęstość brutto w stanie suchym (z wyjątkiem kamienia naturalnego) PN-EN 772-13:2001 Elementy murowe Gestosc netto i gestosc brutto w stanie suchym (z wyjatkiem kamienia naturalnego) PN-EN 772-13:2001","categories":["other"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Masonry units PN-EN 772-13:2001","test_object_en":"Masonry units","search_zh":"砌块 PN-EN 772-13:2001","test_object_zh":"砌块"},{"_id":"6a83760faf14b9c0e7b1f669","lab_id":"69ad52a3de79e566650fb32c","country":"PL","accr_number":"AB 619","accr_body":"PCA","test_object":"Elementy murowe","methodology":"Wymiary","parameters":[{"name":"Zakres","range":"do 2000 mm"}],"technique":null,"techniques":[],"computed":[],"activity":"Wymiary\nZakres do 2000 mm","reference":"PN-EN 772-16:2011","norm_bases":["PN-EN 772-16:2011"],"lab_section":"Laboratorium Badań Materiałów Budowlanych i Ceramicznych; Al. A. Mickiewicza 30, 30-059 Kraków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elementy murowe Wymiary\nZakres do 2000 mm PN-EN 772-16:2011 Elementy murowe Wymiary\nZakres do 2000 mm PN-EN 772-16:2011","categories":["other"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dimensions","parameters_en":[{"name":"Range","range":"do 2000 mm"}],"search_en":"Masonry units Dimensions Range PN-EN 772-16:2011","test_object_en":"Masonry units","parameters_zh":[{"name":"范围","range":"do 2000 mm"}],"search_zh":"砌块 尺寸 范围 PN-EN 772-16:2011","methodology_zh":"尺寸","test_object_zh":"砌块"},{"_id":"6a83760faf14b9c0e7b1f66a","lab_id":"69ad52a3de79e566650fb32c","country":"PL","accr_number":"AB 619","accr_body":"PCA","test_object":"Elementy murowe","methodology":"Odporność na zamrażanie-odmrażanie elementów murowych ceramicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na zamrażanie-odmrażanie elementów murowych ceramicznych","reference":"PN-B-12012:2022-07","norm_bases":["PN-B-12012:2022-07"],"lab_section":"Laboratorium Badań Materiałów Budowlanych i Ceramicznych; Al. A. Mickiewicza 30, 30-059 Kraków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elementy murowe Odporność na zamrażanie-odmrażanie elementów murowych ceramicznych PN-B-12012:2022-07 Elementy murowe Odpornosc na zamrazanie-odmrazanie elementow murowych ceramicznych PN-B-12012:2022-07","categories":["other"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Masonry units PN-B-12012:2022-07","test_object_en":"Masonry units","search_zh":"砌块 PN-B-12012:2022-07","test_object_zh":"砌块"},{"_id":"6a83760faf14b9c0e7b1f66b","lab_id":"69ad52a3de79e566650fb32c","country":"PL","accr_number":"AB 619","accr_body":"PCA","test_object":"Elementy murowe","methodology":"Określenie absorpcji wody ceramicznych i silikatowych elementów murowych przez absorpcję zimnej wody","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Określenie absorpcji wody ceramicznych i silikatowych elementów murowych przez absorpcję zimnej wody","reference":"PN-EN 772-21:2011","norm_bases":["PN-EN 772-21:2011"],"lab_section":"Laboratorium Badań Materiałów Budowlanych i Ceramicznych; Al. A. Mickiewicza 30, 30-059 Kraków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elementy murowe Określenie absorpcji wody ceramicznych i silikatowych elementów murowych przez absorpcję zimnej wody PN-EN 772-21:2011 Elementy murowe Okreslenie absorpcji wody ceramicznych i silikatowych elementow murowych przez absorpcje zimnej wody PN-EN 772-21:2011","categories":["water"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Determination of water absorption of clay and calcium silicate masonry units by cold water absorption","search_en":"Masonry units Determination of water absorption of clay and calcium silicate masonry units by cold water absorption PN-EN 772-21:2011","test_object_en":"Masonry units","search_zh":"砌块 PN-EN 772-21:2011","test_object_zh":"砌块"}],"has_pdf":true}