{"lab":{"_id":"69ad52a3de79e566650fb326","accr_number":"AB 616","country":"PL","accr_body":"PCA","address":"al. Wojska Polskiego 43, 64-920 Piła","categories":["water","microbiology"],"city":"Piła","imported_at":"2026-03-08T10:42:43.265Z","methods_count":43,"name":"POWIATOWA STACJA SANITARNO-EPIDEMIOLOGICZNA W PILE","parse_status":"parsed","parse_version":3,"pdf_files":["AB_616.pdf"],"scope_summary":"","search_text":"powiatowa stacja sanitarno-epidemiologiczna w pile al. wojska polskiego 43, 64-920 piła water other pharma electronics automotive microbiology","status":"active","updated_at":"2026-03-08T14:51:31.008Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:31.008Z","location":{"type":"Point","coordinates":[16.7385,53.151]},"email_confidence":"high","email_mx":true,"email_source":"https://www.pca.gov.pl/akredytowane-podmioty/akredytacje-aktywne/laboratoria-badawcze/AB%20616,plik.html","fields_of_testing":[{"codes":"­ C/28; C/29","pl":"­ Badania chemiczne wody, wody do spożycia przez ludzi","en":"Chemical tests of water, drinking water"},{"codes":"­ K/28; K/29","pl":"­ Badania mikrobiologiczne wody, wody do spożycia przez ludzi","en":"Microbiological tests of water, drinking water"},{"codes":"­ K/3","pl":"­ Badania mikrobiologiczne obiektów i materiałów biologicznych przeznaczonych do badań","en":"Microbiological tests of biological items and materials for testing"},{"codes":"­ N/28; N/29","pl":"­ Badania właściwości fizycznych wody, wody do spożycia przez ludzi","en":"Tests of physical properties of water, drinking water"},{"codes":"­ Q/29","pl":"­ Badania sensoryczne wody do spożycia przez ludzi","en":"Sensory tests of drinking water"}],"issue":{"no":"26","date":"29.05.2025"},"parse_date":"2026-07-20T07:09:45.262Z","parse_source":"script-pdfplumber","map_coord":[53.04734,16.735906],"map_geo":"nominatim-street","has_en":true,"category_counts":{"water":41,"microbiology":8,"materials":1},"category_scores":{"water":33.62,"microbiology":1.28,"materials":0.02},"has_zh":true},"methods":[{"_id":"6a5dc9b9f1c10c8ce825d7b1","lab_id":"69ad52a3de79e566650fb326","country":"PL","accr_number":"AB 616","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Stężenie żelaza","methodology_en":"Iron concentration","parameters":[{"name":"Zakres","range":"(30 – 9000) μg/l"}],"parameters_en":[{"name":"Range","range":"(30 – 9000) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie żelaza\nZakres (30 – 9000) μg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001 | PN-ISO 6332:2001/Ap1:2016-06","norm_bases":["PN-ISO 6332:2001","PN-ISO 6332:2001/Ap1:2016-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie żelaza\nZakres (30 – 9000) μg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001 | PN-ISO 6332:2001/Ap1:2016-06 Woda, Woda do spozycia przez ludzi Stezenie zelaza\nZakres (30 – 9000) μg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001 | PN-ISO 6332:2001/Ap1:2016-06","categories":["water"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Iron concentration Spectrophotometric method Range PN-ISO 6332:2001 | PN-ISO 6332:2001/Ap1:2016-06","methodology_zh":"铁浓度","parameters_zh":[{"name":"范围","range":"(30 – 9000) μg/l"}],"search_zh":"水、生活饮用水 铁浓度 分光光度法 范围 PN-ISO 6332:2001 | PN-ISO 6332:2001/Ap1:2016-06","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9b9f1c10c8ce825d7b2","lab_id":"69ad52a3de79e566650fb326","country":"PL","accr_number":"AB 616","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Stężenie azotynów","methodology_en":"Nitrite concentration","parameters":[{"name":"Zakres","range":"(0,01 – 4,9) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,01 – 4,9) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotynów\nZakres (0,01 – 4,9) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie azotynów\nZakres (0,01 – 4,9) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, Woda do spozycia przez ludzi Stezenie azotynow\nZakres (0,01 – 4,9) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Nitrite concentration Spectrophotometric method Range PN-EN 26777:1999","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,01 – 4,9) mg/l"}],"search_zh":"水、生活饮用水 亚硝酸盐浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9b9f1c10c8ce825d7b3","lab_id":"69ad52a3de79e566650fb326","country":"PL","accr_number":"AB 616","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Stężenie azotanów","methodology_en":"Nitrate concentration","parameters":[{"name":"Zakres","range":"(0,44 – 100) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,44 – 100) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotanów\nZakres (0,44 – 100) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576.08","norm_bases":["PN-82/C-04576.08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie azotanów\nZakres (0,44 – 100) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08 Woda, Woda do spozycia przez ludzi Stezenie azotanow\nZakres (0,44 – 100) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08","categories":["water"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Nitrate concentration Spectrophotometric method Range PN-82/C-04576.08","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,44 – 100) mg/l"}],"search_zh":"水、生活饮用水 硝酸盐浓度 分光光度法 范围 PN-82/C-04576.08","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9b9f1c10c8ce825d7b4","lab_id":"69ad52a3de79e566650fb326","country":"PL","accr_number":"AB 616","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Stężenie jonu amonowego","methodology_en":"Ammonium ion concentration","parameters":[{"name":"Zakres","range":"(0,05 – 12,9) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,05 – 12,9) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie jonu amonowego\nZakres (0,05 – 12,9) mg/l\nMetoda spektrofotometryczna","reference":"PN-C-04576-4:1994","norm_bases":["PN-C-04576-4:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie jonu amonowego\nZakres (0,05 – 12,9) mg/l\nMetoda spektrofotometryczna PN-C-04576-4:1994 Woda, Woda do spozycia przez ludzi Stezenie jonu amonowego\nZakres (0,05 – 12,9) mg/l\nMetoda spektrofotometryczna PN-C-04576-4:1994","categories":["water"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Ammonium ion concentration Spectrophotometric method Range PN-C-04576-4:1994","methodology_zh":"铵离子浓度","parameters_zh":[{"name":"范围","range":"(0,05 – 12,9) mg/l"}],"search_zh":"水、生活饮用水 铵离子浓度 分光光度法 范围 PN-C-04576-4:1994","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9b9f1c10c8ce825d7b5","lab_id":"69ad52a3de79e566650fb326","country":"PL","accr_number":"AB 616","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Stężenie jonu amonowego","methodology_en":"Ammonium ion concentration","parameters":[{"name":"Zakres","range":"(0,13 – 2,58) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,13 – 2,58) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie jonu amonowego\nZakres (0,13 – 2,58) mg/l\nMetoda spektrofotometryczna","reference":"W/PB-36 wyd. 2 z 21.07.2023 r. | na podstawie testu NANOCOLOR nr REF 91805","norm_bases":["W/PB-36 wyd. 2 z 21.07.2023 r.","na podstawie testu NANOCOLOR nr REF 91805"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie jonu amonowego\nZakres (0,13 – 2,58) mg/l\nMetoda spektrofotometryczna W/PB-36 wyd. 2 z 21.07.2023 r. | na podstawie testu NANOCOLOR nr REF 91805 Woda, Woda do spozycia przez ludzi Stezenie jonu amonowego\nZakres (0,13 – 2,58) mg/l\nMetoda spektrofotometryczna W/PB-36 wyd. 2 z 21.07.2023 r. | na podstawie testu NANOCOLOR nr REF 91805","categories":["water"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Ammonium ion concentration Spectrophotometric method Range W/PB-36 wyd. 2 z 21.07.2023 r. | na podstawie testu NANOCOLOR nr REF 91805","methodology_zh":"铵离子浓度","parameters_zh":[{"name":"范围","range":"(0,13 – 2,58) mg/l"}],"search_zh":"水、生活饮用水 铵离子浓度 分光光度法 范围 W/PB-36 wyd. 2 z 21.07.2023 r. | na podstawie testu NANOCOLOR nr REF 91805","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9b9f1c10c8ce825d7b6","lab_id":"69ad52a3de79e566650fb326","country":"PL","accr_number":"AB 616","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, Woda do spozycia przez ludzi pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"水、生活饮用水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9b9f1c10c8ce825d7b7","lab_id":"69ad52a3de79e566650fb326","country":"PL","accr_number":"AB 616","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Przewodność elektryczna właściwa","methodology_en":"Electrical conductivity","parameters":[{"name":"Zakres","range":"(84 – 2700) μS/cm"}],"parameters_en":[{"name":"Range","range":"(84 – 2700) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"technique_en":"Conductometric method","computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa\nZakres (84 – 2700) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Przewodność elektryczna właściwa\nZakres (84 – 2700) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, Woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa\nZakres (84 – 2700) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Electrical conductivity Conductometric method Range PN-EN 27888:1999","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(84 – 2700) μS/cm"}],"search_zh":"水、生活饮用水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9b9f1c10c8ce825d7b8","lab_id":"69ad52a3de79e566650fb326","country":"PL","accr_number":"AB 616","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Barwa","methodology_en":"Colour","parameters":[{"name":"Zakres","range":"(2,5 – 70) mg/l Pt"}],"parameters_en":[{"name":"Range","range":"(2,5 – 70) mg/l Pt"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"technique_en":"Visual method","computed":[],"computed_en":[],"activity":"Barwa\nZakres (2,5 – 70) mg/l Pt\nMetoda wizualna","reference":"PN-EN ISO 7887:2012 Metoda D | PN-EN ISO 7887:2012/Ap1:2015-06","norm_bases":["PN-EN ISO 7887:2012 Metoda D","PN-EN ISO 7887:2012/Ap1:2015-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Barwa\nZakres (2,5 – 70) mg/l Pt\nMetoda wizualna PN-EN ISO 7887:2012 Metoda D | PN-EN ISO 7887:2012/Ap1:2015-06 Woda, Woda do spozycia przez ludzi Barwa\nZakres (2,5 – 70) mg/l Pt\nMetoda wizualna PN-EN ISO 7887:2012 Metoda D | PN-EN ISO 7887:2012/Ap1:2015-06","categories":["water"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Colour Visual method Range PN-EN ISO 7887:2012 Metoda D | PN-EN ISO 7887:2012/Ap1:2015-06","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(2,5 – 70) mg/l Pt"}],"search_zh":"水、生活饮用水 色度 目视法 范围 PN-EN ISO 7887:2012 Metoda D | PN-EN ISO 7887:2012/Ap1:2015-06","technique_zh":"目视法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9b9f1c10c8ce825d7b9","lab_id":"69ad52a3de79e566650fb326","country":"PL","accr_number":"AB 616","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Barwa","methodology_en":"Colour","parameters":[{"name":"Zakres","range":"(2 – 70) mg/l Pt"}],"parameters_en":[{"name":"Range","range":"(2 – 70) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Barwa\nZakres (2 – 70) mg/l Pt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012 Metoda C | PN-EN ISO 7887:2012/Ap1:2015-06","norm_bases":["PN-EN ISO 7887:2012 Metoda C","PN-EN ISO 7887:2012/Ap1:2015-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Barwa\nZakres (2 – 70) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 Metoda C | PN-EN ISO 7887:2012/Ap1:2015-06 Woda, Woda do spozycia przez ludzi Barwa\nZakres (2 – 70) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 Metoda C | PN-EN ISO 7887:2012/Ap1:2015-06","categories":["water"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Colour Spectrophotometric method Range PN-EN ISO 7887:2012 Metoda C | PN-EN ISO 7887:2012/Ap1:2015-06","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(2 – 70) mg/l Pt"}],"search_zh":"水、生活饮用水 色度 分光光度法 范围 PN-EN ISO 7887:2012 Metoda C | PN-EN ISO 7887:2012/Ap1:2015-06","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9b9f1c10c8ce825d7ba","lab_id":"69ad52a3de79e566650fb326","country":"PL","accr_number":"AB 616","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)","methodology_en":"Total content of calcium and magnesium (total hardness)","parameters":[{"name":"Zakres","range":"(10 – 600) mg/l CaCO3"}],"parameters_en":[{"name":"Range","range":"(10 – 600) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (10 – 600) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (10 – 600) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999 Woda, Woda do spozycia przez ludzi Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna)\nZakres (10 – 600) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Total content of calcium and magnesium (total hardness) Titrimetric method Range PN-ISO 6059:1999","methodology_zh":"钙与镁总量（总硬度）","parameters_zh":[{"name":"范围","range":"(10 – 600) mg/l CaCO3"}],"search_zh":"水、生活饮用水 钙与镁总量（总硬度） 滴定法 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9b9f1c10c8ce825d7bb","lab_id":"69ad52a3de79e566650fb326","country":"PL","accr_number":"AB 616","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Stężenie wapnia","methodology_en":"Calcium concentration","parameters":[{"name":"Zakres","range":"(2 – 200) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(2 – 200) mg/dm3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie wapnia\nZakres (2 – 200) mg/dm3\nMetoda miareczkowa","reference":"PN-ISO 6058:1999","norm_bases":["PN-ISO 6058:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie wapnia\nZakres (2 – 200) mg/dm3\nMetoda miareczkowa PN-ISO 6058:1999 Woda, Woda do spozycia przez ludzi Stezenie wapnia\nZakres (2 – 200) mg/dm3\nMetoda miareczkowa PN-ISO 6058:1999","categories":["water"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Calcium concentration Titrimetric method Range PN-ISO 6058:1999","parameters_zh":[{"name":"范围","range":"(2 – 200) mg/dm3"}],"search_zh":"水、生活饮用水 钙浓度 滴定法 范围 PN-ISO 6058:1999","technique_zh":"滴定法","test_object_zh":"水、生活饮用水","methodology_zh":"钙浓度"},{"_id":"6a5dc9b9f1c10c8ce825d7bc","lab_id":"69ad52a3de79e566650fb326","country":"PL","accr_number":"AB 616","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Stężenie magnezu (z obliczeń)","methodology_en":"Magnesium concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie magnezu (z obliczeń)","reference":"PN-C-04554-4:1999 Załącznik A","norm_bases":["PN-C-04554-4:1999 Załącznik A"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie magnezu (z obliczeń) PN-C-04554-4:1999 Załącznik A Woda, Woda do spozycia przez ludzi Stezenie magnezu (z obliczen) PN-C-04554-4:1999 Zalacznik A","categories":["water"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Magnesium concentration (calculated) PN-C-04554-4:1999 Załącznik A","search_zh":"水、生活饮用水 镁浓度（计算值） PN-C-04554-4:1999 Załącznik A","test_object_zh":"水、生活饮用水","methodology_zh":"镁浓度（计算值）"},{"_id":"6a5dc9b9f1c10c8ce825d7bd","lab_id":"69ad52a3de79e566650fb326","country":"PL","accr_number":"AB 616","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Mętność","methodology_en":"Turbidity","parameters":[{"name":"Zakres","range":"(0,20 – 100) NTU"}],"parameters_en":[{"name":"Range","range":"(0,20 – 100) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"technique_en":"Nephelometric method","computed":[],"computed_en":[],"activity":"Mętność\nZakres (0,20 – 100) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Mętność\nZakres (0,20 – 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda, Woda do spozycia przez ludzi Metnosc\nZakres (0,20 – 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,20 – 100) NTU"}],"search_zh":"水、生活饮用水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9b9f1c10c8ce825d7be","lab_id":"69ad52a3de79e566650fb326","country":"PL","accr_number":"AB 616","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Stężenie fluorków","methodology_en":"Fluoride concentration","parameters":[{"name":"Zakres","range":"(0,02 – 5) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,02 – 5) mg/l"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"Stężenie fluorków\nZakres (0,02 – 5) mg/l\nMetoda potencjometryczna","reference":"PN-78/C-04588.03","norm_bases":["PN-78/C-04588.03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie fluorków\nZakres (0,02 – 5) mg/l\nMetoda potencjometryczna PN-78/C-04588.03 Woda, Woda do spozycia przez ludzi Stezenie fluorkow\nZakres (0,02 – 5) mg/l\nMetoda potencjometryczna PN-78/C-04588.03","categories":["water"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Fluoride concentration Potentiometric method Range PN-78/C-04588.03","parameters_zh":[{"name":"范围","range":"(0,02 – 5) mg/l"}],"search_zh":"水、生活饮用水 氟化物浓度 电位法 范围 PN-78/C-04588.03","technique_zh":"电位法","test_object_zh":"水、生活饮用水","methodology_zh":"氟化物浓度"},{"_id":"6a5dc9b9f1c10c8ce825d7bf","lab_id":"69ad52a3de79e566650fb326","country":"PL","accr_number":"AB 616","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Stężenie chlorków","methodology_en":"Chloride concentration","parameters":[{"name":"Zakres","range":"(5 – 500) mg/l"}],"parameters_en":[{"name":"Range","range":"(5 – 500) mg/l"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"Stężenie chlorków\nZakres (5 – 500) mg/l\nMetoda potencjometryczna","reference":"PN-80/C-04617.04","norm_bases":["PN-80/C-04617.04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie chlorków\nZakres (5 – 500) mg/l\nMetoda potencjometryczna PN-80/C-04617.04 Woda, Woda do spozycia przez ludzi Stezenie chlorkow\nZakres (5 – 500) mg/l\nMetoda potencjometryczna PN-80/C-04617.04","categories":["water"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Chloride concentration Potentiometric method Range PN-80/C-04617.04","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5 – 500) mg/l"}],"search_zh":"水、生活饮用水 氯化物浓度 电位法 范围 PN-80/C-04617.04","technique_zh":"电位法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9b9f1c10c8ce825d7c0","lab_id":"69ad52a3de79e566650fb326","country":"PL","accr_number":"AB 616","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Indeks nadmanganianowy","methodology_en":"Permanganate index","parameters":[{"name":"Zakres","range":"(0,5 – 10) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(0,5 – 10) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Indeks nadmanganianowy\nZakres (0,5 – 10) mg/l O2\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Indeks nadmanganianowy\nZakres (0,5 – 10) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda, Woda do spozycia przez ludzi Indeks nadmanganianowy\nZakres (0,5 – 10) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Permanganate index Titrimetric method Range PN-EN ISO 8467:2001","methodology_zh":"高锰酸盐指数","parameters_zh":[{"name":"范围","range":"(0,5 – 10) mg/l O2"}],"search_zh":"水、生活饮用水 高锰酸盐指数 滴定法 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9b9f1c10c8ce825d7c1","lab_id":"69ad52a3de79e566650fb326","country":"PL","accr_number":"AB 616","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Stężenie wielopierścieniowych węglowodorów aromatycznych WWA","methodology_en":"Polycyclic aromatic hydrocarbons PAH concentration","parameters":[{"name":"Benzo(a)piren","range":"(0,003 – 0,05) μg/l"},{"name":"Benzo(b)fluoranten"},{"name":"Zakres","range":"(0,005 – 0,05) μg/l"},{"name":"Benzo(k)fluoranten","range":"(0,005 – 0,05) μg/l"},{"name":"Benzo(g,h,i)perylen","range":"(0,005 – 0,05) μg/l"},{"name":"Indeno","range":"(1,2,3-c,d)piren"},{"name":"(0,005 – 0,05) μg/l"},{"name":"Suma wielopierścieniowych węglowodorów aromatycznych WWA (z obliczeń)"}],"parameters_en":[{"name":"Benzo(a)pyrene","range":"(0,003 – 0,05) μg/l"},{"name":"Benzo(b)fluoranthene"},{"name":"Range","range":"(0,005 – 0,05) μg/l"},{"name":"Benzo(k)fluoranthene","range":"(0,005 – 0,05) μg/l"},{"name":"Benzo(g,h,i)perylene","range":"(0,005 – 0,05) μg/l"},{"name":"Indeno","range":"(1,2,3-c,d)piren"},{"name":"(0,005 – 0,05) μg/l"},{"name":"Sum of polycyclic aromatic hydrocarbons PAH (calculated)"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD)","computed":[],"computed_en":[],"activity":"Stężenie wielopierścieniowych węglowodorów aromatycznych WWA\nZakres:\nBenzo(a)piren (0,003 – 0,05) μg/l\nBenzo(b)fluoranten\nZakres (0,005 – 0,05) μg/l\nBenzo(k)fluoranten (0,005 – 0,05) μg/l\nBenzo(g,h,i)perylen (0,005 – 0,05) μg/l\nIndeno (1,2,3-c,d)piren\n(0,005 – 0,05) μg/l\nSuma wielopierścieniowych węglowodorów aromatycznych WWA (z obliczeń)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"W/PB-35 wyd. 4 z dnia 11.12.2024 r.","norm_bases":["W/PB-35 wyd. 4 z dnia 11.12.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie wielopierścieniowych węglowodorów aromatycznych WWA\nZakres:\nBenzo(a)piren (0,003 – 0,05) μg/l\nBenzo(b)fluoranten\nZakres (0,005 – 0,05) μg/l\nBenzo(k)fluoranten (0,005 – 0,05) μg/l\nBenzo(g,h,i)perylen (0,005 – 0,05) μg/l\nIndeno (1,2,3-c,d)piren\n(0,005 – 0,05) μg/l\nSuma wielopierścieniowych węglowodorów aromatycznych WWA (z obliczeń)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) W/PB-35 wyd. 4 z dnia 11.12.2024 r. Woda, Woda do spozycia przez ludzi Stezenie wielopierscieniowych weglowodorow aromatycznych WWA\nZakres:\nBenzo(a)piren (0,003 – 0,05) μg/l\nBenzo(b)fluoranten\nZakres (0,005 – 0,05) μg/l\nBenzo(k)fluoranten (0,005 – 0,05) μg/l\nBenzo(g,h,i)perylen (0,005 – 0,05) μg/l\nIndeno (1,2,3-c,d)piren\n(0,005 – 0,05) μg/l\nSuma wielopierscieniowych weglowodorow aromatycznych WWA (z obliczen)\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) W/PB-35 wyd. 4 z dnia 11.12.2024 r.","categories":["water"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Polycyclic aromatic hydrocarbons PAH concentration High-performance liquid chromatography with fluorescence detection (HPLC-FLD) Benzo(a)pyrene Benzo(b)fluoranthene Range Benzo(k)fluoranthene Benzo(g,h,i)perylene Indeno (0,005 – 0,05) μg/l Sum of polycyclic aromatic hydrocarbons PAH (calculated) W/PB-35 wyd. 4 z dnia 11.12.2024 r.","parameters_zh":[{"name":"苯并(a)芘","range":"(0,003 – 0,05) μg/l"},{"name":"苯并(b)荧蒽"},{"name":"范围","range":"(0,005 – 0,05) μg/l"},{"name":"苯并(k)荧蒽","range":"(0,005 – 0,05) μg/l"},{"name":"苯并(g,h,i)苝","range":"(0,005 – 0,05) μg/l"},{"name":"茚并","range":"(1,2,3-c,d)piren"},{"name":"(0,005 – 0,05) μg/l"},{"name":"Suma wielopierścieniowych węglowodorów aromatycznych WWA (z obliczeń)"}],"search_zh":"水、生活饮用水 多环芳烃 PAH 浓度 高效液相色谱-荧光检测法（HPLC-FLD） 苯并(a)芘 苯并(b)荧蒽 范围 苯并(k)荧蒽 苯并(g,h,i)苝 茚并 W/PB-35 wyd. 4 z dnia 11.12.2024 r.","technique_zh":"高效液相色谱-荧光检测法（HPLC-FLD）","test_object_zh":"水、生活饮用水","methodology_zh":"多环芳烃 PAH 浓度"},{"_id":"6a5dc9b9f1c10c8ce825d7c2","lab_id":"69ad52a3de79e566650fb326","country":"PL","accr_number":"AB 616","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Stężenie sodu","methodology_en":"Sodium concentration","parameters":[{"name":"Zakres","range":"(5 – 250) mg/l"}],"parameters_en":[{"name":"Range","range":"(5 – 250) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"technique_en":"Flame atomic absorption spectrometry (FAAS)","computed":[],"computed_en":[],"activity":"Stężenie sodu\nZakres (5 – 250) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 9964-1:1994 | PN-ISO 9964-1:1994/Ap1:2009","norm_bases":["PN-ISO 9964-1:1994","PN-ISO 9964-1:1994/Ap1:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie sodu\nZakres (5 – 250) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 9964-1:1994 | PN-ISO 9964-1:1994/Ap1:2009 Woda, Woda do spozycia przez ludzi Stezenie sodu\nZakres (5 – 250) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 9964-1:1994 | PN-ISO 9964-1:1994/Ap1:2009","categories":["water"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Sodium concentration Flame atomic absorption spectrometry (FAAS) Range PN-ISO 9964-1:1994 | PN-ISO 9964-1:1994/Ap1:2009","parameters_zh":[{"name":"范围","range":"(5 – 250) mg/l"}],"search_zh":"水、生活饮用水 钠浓度 火焰原子吸收光谱法（FAAS） 范围 PN-ISO 9964-1:1994 | PN-ISO 9964-1:1994/Ap1:2009","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"水、生活饮用水","methodology_zh":"钠浓度"},{"_id":"6a5dc9b9f1c10c8ce825d7c3","lab_id":"69ad52a3de79e566650fb326","country":"PL","accr_number":"AB 616","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Stężenie siarczanów","methodology_en":"Sulfate concentration","parameters":[{"name":"Zakres","range":"(2,5 – 400) mg/l"}],"parameters_en":[{"name":"Range","range":"(2,5 – 400) mg/l"}],"technique":"Metoda turbidymetryczna","techniques":["Metoda turbidymetryczna"],"technique_en":"Turbidimetric method","computed":[],"computed_en":[],"activity":"Stężenie siarczanów\nZakres (2,5 – 400) mg/l\nMetoda turbidymetryczna","reference":"PN-79/C-04566.10","norm_bases":["PN-79/C-04566.10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie siarczanów\nZakres (2,5 – 400) mg/l\nMetoda turbidymetryczna PN-79/C-04566.10 Woda, Woda do spozycia przez ludzi Stezenie siarczanow\nZakres (2,5 – 400) mg/l\nMetoda turbidymetryczna PN-79/C-04566.10","categories":["water"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Sulfate concentration Turbidimetric method Range PN-79/C-04566.10","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(2,5 – 400) mg/l"}],"search_zh":"水、生活饮用水 硫酸盐浓度 浊度法 范围 PN-79/C-04566.10","test_object_zh":"水、生活饮用水","technique_zh":"浊度法"},{"_id":"6a5dc9b9f1c10c8ce825d7c4","lab_id":"69ad52a3de79e566650fb326","country":"PL","accr_number":"AB 616","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Stężenie manganu","methodology_en":"Manganese concentration","parameters":[{"name":"Zakres","range":"(15 – 900) μg/l"}],"parameters_en":[{"name":"Range","range":"(15 – 900) μg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"technique_en":"Flame atomic absorption spectrometry (FAAS)","computed":[],"computed_en":[],"activity":"Stężenie manganu\nZakres (15 – 900) μg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-92/C-04570/01","norm_bases":["PN-92/C-04570/01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie manganu\nZakres (15 – 900) μg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-92/C-04570/01 Woda, Woda do spozycia przez ludzi Stezenie manganu\nZakres (15 – 900) μg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-92/C-04570/01","categories":["water"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Manganese concentration Flame atomic absorption spectrometry (FAAS) Range PN-92/C-04570/01","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(15 – 900) μg/l"}],"search_zh":"水、生活饮用水 锰浓度 火焰原子吸收光谱法（FAAS） 范围 PN-92/C-04570/01","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9b9f1c10c8ce825d7c5","lab_id":"69ad52a3de79e566650fb326","country":"PL","accr_number":"AB 616","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Stężenie anionów","methodology_en":"Anion concentrations","parameters":[{"name":"Azotany","range":"(0,1 – 100) mg/dm3"},{"name":"Azotyny","range":"(0,05 – 2,5) mg/dm3"},{"name":"Chlorki","range":"(2 – 500) mg/dm3"},{"name":"Fluorki","range":"(0,1 – 5,0) mg/dm3"},{"name":"Siarczany","range":"(2 – 500) mg/dm3"}],"parameters_en":[{"name":"Nitrates","range":"(0,1 – 100) mg/dm3"},{"name":"Nitrites","range":"(0,05 – 2,5) mg/dm3"},{"name":"Chlorides","range":"(2 – 500) mg/dm3"},{"name":"Fluorides","range":"(0,1 – 5,0) mg/dm3"},{"name":"Sulfates","range":"(2 – 500) mg/dm3"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"technique_en":"Ion chromatography with conductometric detection (IC-CD)","computed":[],"computed_en":[],"activity":"Stężenie anionów\nZakres:\nAzotany (0,1 – 100) mg/dm3\nAzotyny (0,05 – 2,5) mg/dm3\nChlorki (2 – 500) mg/dm3\nFluorki (0,1 – 5,0) mg/dm3\nSiarczany (2 – 500) mg/dm3\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009 | PN-EN ISO 10304-1:2009/AC:2012","norm_bases":["PN-EN ISO 10304-1:2009","PN-EN ISO 10304-1:2009/AC:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie anionów\nZakres:\nAzotany (0,1 – 100) mg/dm3\nAzotyny (0,05 – 2,5) mg/dm3\nChlorki (2 – 500) mg/dm3\nFluorki (0,1 – 5,0) mg/dm3\nSiarczany (2 – 500) mg/dm3\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009 | PN-EN ISO 10304-1:2009/AC:2012 Woda, Woda do spozycia przez ludzi Stezenie anionow\nZakres:\nAzotany (0,1 – 100) mg/dm3\nAzotyny (0,05 – 2,5) mg/dm3\nChlorki (2 – 500) mg/dm3\nFluorki (0,1 – 5,0) mg/dm3\nSiarczany (2 – 500) mg/dm3\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009 | PN-EN ISO 10304-1:2009/AC:2012","categories":["water"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Anion concentrations Ion chromatography with conductometric detection (IC-CD) Nitrates Nitrites Chlorides Fluorides Sulfates PN-EN ISO 10304-1:2009 | PN-EN ISO 10304-1:2009/AC:2012","methodology_zh":"阴离子浓度","parameters_zh":[{"name":"硝酸盐","range":"(0,1 – 100) mg/dm3"},{"name":"亚硝酸盐","range":"(0,05 – 2,5) mg/dm3"},{"name":"氯化物","range":"(2 – 500) mg/dm3"},{"name":"氟化物","range":"(0,1 – 5,0) mg/dm3"},{"name":"硫酸盐","range":"(2 – 500) mg/dm3"}],"search_zh":"水、生活饮用水 阴离子浓度 离子色谱-电导检测法（IC-CD） 硝酸盐 亚硝酸盐 氯化物 氟化物 硫酸盐 PN-EN ISO 10304-1:2009 | PN-EN ISO 10304-1:2009/AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9b9f1c10c8ce825d7c6","lab_id":"69ad52a3de79e566650fb326","country":"PL","accr_number":"AB 616","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Stężenie chloranów","methodology_en":"Chlorate concentration","parameters":[{"name":"Zakres","range":"(0,050 – 1,0) mg/dm3"},{"name":"Stężenie chlorynów"},{"name":"Zakres","range":"(0,050 – 1,0) mg/dm3"},{"name":"Suma stężeń chloranów i chlorynów (z obliczeń)"}],"parameters_en":[{"name":"Range","range":"(0,050 – 1,0) mg/dm3"},{"name":"Chlorite concentration"},{"name":"Range","range":"(0,050 – 1,0) mg/dm3"},{"name":"Sum of chlorate and chlorite concentrations (calculated)"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"technique_en":"Ion chromatography with conductometric detection (IC-CD)","computed":[],"computed_en":[],"activity":"Stężenie chloranów\nZakres:\nZakres (0,050 – 1,0) mg/dm3\nStężenie chlorynów\nZakres (0,050 – 1,0) mg/dm3\nSuma stężeń chloranów i chlorynów (z obliczeń)\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-4:2022-08","norm_bases":["PN-EN ISO 10304-4:2022-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie chloranów\nZakres:\nZakres (0,050 – 1,0) mg/dm3\nStężenie chlorynów\nZakres (0,050 – 1,0) mg/dm3\nSuma stężeń chloranów i chlorynów (z obliczeń)\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-4:2022-08 Woda, Woda do spozycia przez ludzi Stezenie chloranow\nZakres:\nZakres (0,050 – 1,0) mg/dm3\nStezenie chlorynow\nZakres (0,050 – 1,0) mg/dm3\nSuma stezen chloranow i chlorynow (z obliczen)\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-4:2022-08","categories":["water"],"row_index":21,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Chlorate concentration Ion chromatography with conductometric detection (IC-CD) Range Chlorite concentration Range Sum of chlorate and chlorite concentrations (calculated) PN-EN ISO 10304-4:2022-08","parameters_zh":[{"name":"范围","range":"(0,050 – 1,0) mg/dm3"},{"name":"亚氯酸盐浓度"},{"name":"范围","range":"(0,050 – 1,0) mg/dm3"},{"name":"Suma stężeń chloranów i chlorynów (z obliczeń)"}],"search_zh":"水、生活饮用水 氯酸盐浓度 离子色谱-电导检测法（IC-CD） 范围 亚氯酸盐浓度 范围 PN-EN ISO 10304-4:2022-08","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水、生活饮用水","methodology_zh":"氯酸盐浓度"},{"_id":"6a5dc9b9f1c10c8ce825d7c7","lab_id":"69ad52a3de79e566650fb326","country":"PL","accr_number":"AB 616","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Obecność obcego zapachu (metoda jakościowa) Liczba progowa zapachu TON","methodology_en":"Presence of foreign odour (qualitative method) Threshold odour number TON","parameters":[{"name":"Zakres","range":"2"}],"parameters_en":[{"name":"Range","range":"2"}],"technique":"Metoda uproszczona, parzysta, wybór niewymuszony","techniques":["Metoda uproszczona, parzysta, wybór niewymuszony"],"technique_en":"Simplified method, paired, non-forced choice","computed":[],"computed_en":[],"activity":"Obecność obcego zapachu (metoda jakościowa) Liczba progowa zapachu TON\nZakres 2\nMetoda uproszczona, parzysta, wybór niewymuszony","reference":"PN-EN 1622:2006","norm_bases":["PN-EN 1622:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Obecność obcego zapachu (metoda jakościowa) Liczba progowa zapachu TON\nZakres 2\nMetoda uproszczona, parzysta, wybór niewymuszony PN-EN 1622:2006 Woda do spozycia przez ludzi Obecnosc obcego zapachu (metoda jakosciowa) Liczba progowa zapachu TON\nZakres 2\nMetoda uproszczona, parzysta, wybor niewymuszony PN-EN 1622:2006","categories":["water"],"row_index":22,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Presence of foreign odour (qualitative method) Threshold odour number TON Simplified method, paired, non-forced choice Range PN-EN 1622:2006","parameters_zh":[{"name":"范围","range":"2"}],"search_zh":"生活饮用水 简化法，成对，非强制选择 范围 PN-EN 1622:2006","test_object_zh":"生活饮用水","technique_zh":"简化法，成对，非强制选择"},{"_id":"6a5dc9b9f1c10c8ce825d7c8","lab_id":"69ad52a3de79e566650fb326","country":"PL","accr_number":"AB 616","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Obecność obcego smaku (metoda jakościowa) Liczba progowa smaku TFN","methodology_en":"Presence of foreign taste (qualitative method) Threshold flavour number TFN","parameters":[{"name":"Zakres","range":"2"}],"parameters_en":[{"name":"Range","range":"2"}],"technique":"Metoda uproszczona, parzysta, wybór niewymuszony","techniques":["Metoda uproszczona, parzysta, wybór niewymuszony"],"technique_en":"Simplified method, paired, non-forced choice","computed":[],"computed_en":[],"activity":"Obecność obcego smaku (metoda jakościowa) Liczba progowa smaku TFN\nZakres 2\nMetoda uproszczona, parzysta, wybór niewymuszony","reference":"PN-EN 1622:2006","norm_bases":["PN-EN 1622:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Obecność obcego smaku (metoda jakościowa) Liczba progowa smaku TFN\nZakres 2\nMetoda uproszczona, parzysta, wybór niewymuszony PN-EN 1622:2006 Woda do spozycia przez ludzi Obecnosc obcego smaku (metoda jakosciowa) Liczba progowa smaku TFN\nZakres 2\nMetoda uproszczona, parzysta, wybor niewymuszony PN-EN 1622:2006","categories":["water"],"row_index":23,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Presence of foreign taste (qualitative method) Threshold flavour number TFN Simplified method, paired, non-forced choice Range PN-EN 1622:2006","parameters_zh":[{"name":"范围","range":"2"}],"search_zh":"生活饮用水 简化法，成对，非强制选择 范围 PN-EN 1622:2006","test_object_zh":"生活饮用水","technique_zh":"简化法，成对，非强制选择"},{"_id":"6a5dc9b9f1c10c8ce825d7c9","lab_id":"69ad52a3de79e566650fb326","country":"PL","accr_number":"AB 616","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Stężenie azotanów","methodology_en":"Nitrate concentration","parameters":[{"name":"Zakres","range":"(0,44 – 100) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,44 – 100) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotanów\nZakres (0,44 – 100) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576.08","norm_bases":["PN-82/C-04576.08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Stężenie azotanów\nZakres (0,44 – 100) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08 Woda na plywalniach Stezenie azotanow\nZakres (0,44 – 100) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08","categories":["water"],"row_index":24,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water Nitrate concentration Spectrophotometric method Range PN-82/C-04576.08","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,44 – 100) mg/l"}],"search_zh":"游泳池水 硝酸盐浓度 分光光度法 范围 PN-82/C-04576.08","technique_zh":"分光光度法","test_object_zh":"游泳池水"},{"_id":"6a5dc9b9f1c10c8ce825d7ca","lab_id":"69ad52a3de79e566650fb326","country":"PL","accr_number":"AB 616","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Mętność","methodology_en":"Turbidity","parameters":[{"name":"Zakres","range":"(0,20 – 100) NTU"}],"parameters_en":[{"name":"Range","range":"(0,20 – 100) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"technique_en":"Nephelometric method","computed":[],"computed_en":[],"activity":"Mętność\nZakres (0,20 – 100) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Mętność\nZakres (0,20 – 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda na plywalniach Metnosc\nZakres (0,20 – 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":25,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,20 – 100) NTU"}],"search_zh":"游泳池水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"游泳池水"},{"_id":"6a5dc9b9f1c10c8ce825d7cb","lab_id":"69ad52a3de79e566650fb326","country":"PL","accr_number":"AB 616","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Indeks nadmanganianowy","methodology_en":"Permanganate index","parameters":[{"name":"Zakres","range":"(0,5 – 10) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(0,5 – 10) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Indeks nadmanganianowy\nZakres (0,5 – 10) mg/l O2\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Indeks nadmanganianowy\nZakres (0,5 – 10) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda na plywalniach Indeks nadmanganianowy\nZakres (0,5 – 10) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":26,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water Permanganate index Titrimetric method Range PN-EN ISO 8467:2001","methodology_zh":"高锰酸盐指数","parameters_zh":[{"name":"范围","range":"(0,5 – 10) mg/l O2"}],"search_zh":"游泳池水 高锰酸盐指数 滴定法 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"游泳池水"},{"_id":"6a5dc9b9f1c10c8ce825d7cc","lab_id":"69ad52a3de79e566650fb326","country":"PL","accr_number":"AB 616","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Stężenie azotanów","methodology_en":"Nitrate concentration","parameters":[{"name":"Zakres","range":"(1 – 100) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(1 – 100) mg/dm3"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"technique_en":"Ion chromatography with conductometric detection (IC-CD)","computed":[],"computed_en":[],"activity":"Stężenie azotanów\nZakres (1 – 100) mg/dm3\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009 | PN-EN ISO 10304-1:2009/AC:2012","norm_bases":["PN-EN ISO 10304-1:2009","PN-EN ISO 10304-1:2009/AC:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Stężenie azotanów\nZakres (1 – 100) mg/dm3\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009 | PN-EN ISO 10304-1:2009/AC:2012 Woda na plywalniach Stezenie azotanow\nZakres (1 – 100) mg/dm3\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009 | PN-EN ISO 10304-1:2009/AC:2012","categories":["water"],"row_index":27,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water Nitrate concentration Ion chromatography with conductometric detection (IC-CD) Range PN-EN ISO 10304-1:2009 | PN-EN ISO 10304-1:2009/AC:2012","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(1 – 100) mg/dm3"}],"search_zh":"游泳池水 硝酸盐浓度 离子色谱-电导检测法（IC-CD） 范围 PN-EN ISO 10304-1:2009 | PN-EN ISO 10304-1:2009/AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"游泳池水"},{"_id":"6a5dc9b9f1c10c8ce825d7cd","lab_id":"69ad52a3de79e566650fb326","country":"PL","accr_number":"AB 616","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Najbardziej prawdopodobna liczba, Escherichia coli","methodology_en":"Most probable number, Escherichia coli","parameters":[],"parameters_en":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"technique_en":"MPN method","computed":[],"computed_en":[],"activity":"Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda NPL","reference":"PN-EN ISO 9308-3:2002","norm_bases":["PN-EN ISO 9308-3:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda NPL PN-EN ISO 9308-3:2002 Woda Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda NPL PN-EN ISO 9308-3:2002","categories":["water","microbiology"],"row_index":28,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Most probable number, Escherichia coli MPN method PN-EN ISO 9308-3:2002","methodology_zh":"大肠埃希氏菌（Escherichia coli）最可能数（MPN）","search_zh":"水 大肠埃希氏菌（Escherichia coli）最可能数（MPN） 最可能数法（MPN） PN-EN ISO 9308-3:2002","technique_zh":"最可能数法（MPN）","test_object_zh":"水"},{"_id":"6a5dc9b9f1c10c8ce825d7ce","lab_id":"69ad52a3de79e566650fb326","country":"PL","accr_number":"AB 616","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Liczba enterokoków kałowych","methodology_en":"Intestinal enterococci count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba enterokoków kałowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Liczba enterokoków kałowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda, Woda do spozycia przez ludzi Liczba enterokokow kalowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":29,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004","methodology_zh":"粪肠球菌计数","search_zh":"水、生活饮用水 粪肠球菌计数 膜过滤法 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9b9f1c10c8ce825d7cf","lab_id":"69ad52a3de79e566650fb326","country":"PL","accr_number":"AB 616","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Liczba bakterii grupy coli","methodology_en":"Coliform bacteria count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12","PN-EN ISO 9308-1:2014-12 /A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04 Woda, Woda do spozycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04","categories":["water","microbiology"],"row_index":30,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04","methodology_zh":"大肠菌群计数","search_zh":"水、生活饮用水 大肠菌群计数 膜过滤法 PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9b9f1c10c8ce825d7d0","lab_id":"69ad52a3de79e566650fb326","country":"PL","accr_number":"AB 616","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Liczba Escherichia coli","methodology_en":"Escherichia coli count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12","PN-EN ISO 9308-1:2014-12 /A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04 Woda, Woda do spozycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04","categories":["water","microbiology"],"row_index":31,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"水、生活饮用水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9b9f1c10c8ce825d7d1","lab_id":"69ad52a3de79e566650fb326","country":"PL","accr_number":"AB 616","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Ogólna liczba mikroorganizmów w 36oC","methodology_en":"Total viable count at 36oC","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa - posiew wgłębny","techniques":["Metoda płytkowa - posiew wgłębny"],"technique_en":"Plate method - pour plate","computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w 36oC\nMetoda płytkowa - posiew wgłębny","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 36oC\nMetoda płytkowa - posiew wgłębny PN-EN ISO 6222:2004 Woda, Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 36oC\nMetoda plytkowa - posiew wglebny PN-EN ISO 6222:2004","categories":["water"],"row_index":32,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Total viable count at 36oC Plate method - pour plate PN-EN ISO 6222:2004","search_zh":"水、生活饮用水 36oC 微生物总数 平板法 － 倾注平板 PN-EN ISO 6222:2004","test_object_zh":"水、生活饮用水","methodology_zh":"36oC 微生物总数","technique_zh":"平板法 － 倾注平板"},{"_id":"6a5dc9b9f1c10c8ce825d7d2","lab_id":"69ad52a3de79e566650fb326","country":"PL","accr_number":"AB 616","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Ogólna liczba mikroorganizmów w 22oC","methodology_en":"Total viable count at 22oC","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa - posiew wgłębny","techniques":["Metoda płytkowa - posiew wgłębny"],"technique_en":"Plate method - pour plate","computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w 22oC\nMetoda płytkowa - posiew wgłębny","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 22oC\nMetoda płytkowa - posiew wgłębny PN-EN ISO 6222:2004 Woda, Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 22oC\nMetoda plytkowa - posiew wglebny PN-EN ISO 6222:2004","categories":["water"],"row_index":33,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Total viable count at 22oC Plate method - pour plate PN-EN ISO 6222:2004","search_zh":"水、生活饮用水 22oC 微生物总数 平板法 － 倾注平板 PN-EN ISO 6222:2004","test_object_zh":"水、生活饮用水","methodology_zh":"22oC 微生物总数","technique_zh":"平板法 － 倾注平板"},{"_id":"6a5dc9b9f1c10c8ce825d7d3","lab_id":"69ad52a3de79e566650fb326","country":"PL","accr_number":"AB 616","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Liczba bakterii z rodzaju Legionella","methodology_en":"Count of bacteria of the genus Legionella","parameters":[{"name":"Matryca A Procedura 5 (pożywka BCYE) 7 (pożywka GVPC)"}],"parameters_en":[{"name":"Matrix A Procedure 5 (medium BCYE) 7 (medium GVPC)"}],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba bakterii z rodzaju Legionella\nMatryca A Procedura 5 (pożywka BCYE) 7 (pożywka GVPC)\nMetoda filtracji membranowej","reference":"PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08 /Ap1:2019-12","norm_bases":["PN-EN ISO 11731:2017-08","PN-EN ISO 11731:2017-08 /Ap1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Liczba bakterii z rodzaju Legionella\nMatryca A Procedura 5 (pożywka BCYE) 7 (pożywka GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08 /Ap1:2019-12 Woda, Woda do spozycia przez ludzi Liczba bakterii z rodzaju Legionella\nMatryca A Procedura 5 (pozywka BCYE) 7 (pozywka GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08 /Ap1:2019-12","categories":["microbiology","water"],"row_index":34,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Count of bacteria of the genus Legionella Membrane filtration method Matrix A Procedure 5 (medium BCYE) 7 (medium GVPC) PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08 /Ap1:2019-12","search_zh":"水、生活饮用水 军团菌属细菌计数 膜过滤法 PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08 /Ap1:2019-12","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水","methodology_zh":"军团菌属细菌计数"},{"_id":"6a5dc9b9f1c10c8ce825d7d4","lab_id":"69ad52a3de79e566650fb326","country":"PL","accr_number":"AB 616","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Liczba Clostridium perfringens (łącznie ze sporami)","methodology_en":"Clostridium perfringens count (including spores)","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Clostridium perfringens (łącznie ze sporami)\nMetoda filtracji membranowej","reference":"PN-EN ISO 14189:2016-10","norm_bases":["PN-EN ISO 14189:2016-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Liczba Clostridium perfringens (łącznie ze sporami)\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10 Woda, Woda do spozycia przez ludzi Liczba Clostridium perfringens (lacznie ze sporami)\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10","categories":["water"],"row_index":35,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Clostridium perfringens count (including spores) Membrane filtration method PN-EN ISO 14189:2016-10","search_zh":"水、生活饮用水 产气荚膜梭菌计数（含芽孢） 膜过滤法 PN-EN ISO 14189:2016-10","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水","methodology_zh":"产气荚膜梭菌计数（含芽孢）"},{"_id":"6a5dc9b9f1c10c8ce825d7d5","lab_id":"69ad52a3de79e566650fb326","country":"PL","accr_number":"AB 616","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Liczba Pseudomonas aeruginosa","methodology_en":"Pseudomonas aeruginosa count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009 Woda, Woda do spozycia przez ludzi Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water"],"row_index":36,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009","methodology_zh":"铜绿假单胞菌计数","search_zh":"水、生活饮用水 铜绿假单胞菌计数 膜过滤法 PN-EN ISO 16266:2009","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9b9f1c10c8ce825d7d6","lab_id":"69ad52a3de79e566650fb326","country":"PL","accr_number":"AB 616","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Ogólna liczba mikroorganizmów w 36oC","methodology_en":"Total viable count at 36oC","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa - posiew wgłębny","techniques":["Metoda płytkowa - posiew wgłębny"],"technique_en":"Plate method - pour plate","computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w 36oC\nMetoda płytkowa - posiew wgłębny","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Ogólna liczba mikroorganizmów w 36oC\nMetoda płytkowa - posiew wgłębny PN-EN ISO 6222:2004 Woda na plywalniach Ogolna liczba mikroorganizmow w 36oC\nMetoda plytkowa - posiew wglebny PN-EN ISO 6222:2004","categories":["water"],"row_index":37,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water Total viable count at 36oC Plate method - pour plate PN-EN ISO 6222:2004","search_zh":"游泳池水 36oC 微生物总数 平板法 － 倾注平板 PN-EN ISO 6222:2004","test_object_zh":"游泳池水","methodology_zh":"36oC 微生物总数","technique_zh":"平板法 － 倾注平板"},{"_id":"6a5dc9b9f1c10c8ce825d7d7","lab_id":"69ad52a3de79e566650fb326","country":"PL","accr_number":"AB 616","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Liczba Escherichia coli","methodology_en":"Escherichia coli count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12","PN-EN ISO 9308-1:2014-12 /A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04 Woda na plywalniach Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04","categories":["water","microbiology"],"row_index":38,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"游泳池水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"游泳池水"},{"_id":"6a5dc9b9f1c10c8ce825d7d8","lab_id":"69ad52a3de79e566650fb326","country":"PL","accr_number":"AB 616","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Liczba Pseudomonas aeruginosa","methodology_en":"Pseudomonas aeruginosa count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009 Woda na plywalniach Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water"],"row_index":39,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009","methodology_zh":"铜绿假单胞菌计数","search_zh":"游泳池水 铜绿假单胞菌计数 膜过滤法 PN-EN ISO 16266:2009","technique_zh":"膜过滤法","test_object_zh":"游泳池水"},{"_id":"6a5dc9b9f1c10c8ce825d7d9","lab_id":"69ad52a3de79e566650fb326","country":"PL","accr_number":"AB 616","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Liczba bakterii z rodzaju Legionella","methodology_en":"Count of bacteria of the genus Legionella","parameters":[{"name":"Matryca A Procedura 5 (pożywka BCYE) 7 (pożywka GVPC)"}],"parameters_en":[{"name":"Matrix A Procedure 5 (medium BCYE) 7 (medium GVPC)"}],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba bakterii z rodzaju Legionella\nMatryca A Procedura 5 (pożywka BCYE) 7 (pożywka GVPC)\nMetoda filtracji membranowej","reference":"PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08 /Ap1:2019-12","norm_bases":["PN-EN ISO 11731:2017-08","PN-EN ISO 11731:2017-08 /Ap1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Liczba bakterii z rodzaju Legionella\nMatryca A Procedura 5 (pożywka BCYE) 7 (pożywka GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08 /Ap1:2019-12 Woda na plywalniach Liczba bakterii z rodzaju Legionella\nMatryca A Procedura 5 (pozywka BCYE) 7 (pozywka GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08 /Ap1:2019-12","categories":["microbiology","water"],"row_index":40,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water Count of bacteria of the genus Legionella Membrane filtration method Matrix A Procedure 5 (medium BCYE) 7 (medium GVPC) PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08 /Ap1:2019-12","search_zh":"游泳池水 军团菌属细菌计数 膜过滤法 PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08 /Ap1:2019-12","technique_zh":"膜过滤法","test_object_zh":"游泳池水","methodology_zh":"军团菌属细菌计数"},{"_id":"6a5dc9b9f1c10c8ce825d7da","lab_id":"69ad52a3de79e566650fb326","country":"PL","accr_number":"AB 616","accr_body":"PCA","test_object":"Materiał biologiczny ludzki (kał, wymaz z odbytu)","test_object_en":"Human biological material (faeces, rectal swab)","methodology":"Obecność i identyfikacja pałeczek, Salmonella, Shigella","methodology_en":"Presence and identification of rods, Salmonella, Shigella","parameters":[],"parameters_en":[],"technique":"Metoda hodowlana, uzupełniona testami biochemicznymi i serologicznymi","techniques":["Metoda hodowlana, uzupełniona testami biochemicznymi i serologicznymi"],"technique_en":"Culture method, supplemented with biochemical and serological tests","computed":[],"computed_en":[],"activity":"Obecność i identyfikacja pałeczek, Salmonella, Shigella\nMetoda hodowlana, uzupełniona testami biochemicznymi i serologicznymi","reference":"M/PB-01 wyd. 6 z dnia 21.07.2023 r.","norm_bases":["M/PB-01 wyd. 6 z dnia 21.07.2023 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiał biologiczny ludzki (kał, wymaz z odbytu) Obecność i identyfikacja pałeczek, Salmonella, Shigella\nMetoda hodowlana, uzupełniona testami biochemicznymi i serologicznymi M/PB-01 wyd. 6 z dnia 21.07.2023 r. Material biologiczny ludzki (kal, wymaz z odbytu) Obecnosc i identyfikacja paleczek, Salmonella, Shigella\nMetoda hodowlana, uzupelniona testami biochemicznymi i serologicznymi M/PB-01 wyd. 6 z dnia 21.07.2023 r.","categories":["microbiology","materials"],"row_index":41,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Human biological material (faeces, rectal swab) Presence and identification of rods, Salmonella, Shigella Culture method, supplemented with biochemical and serological tests M/PB-01 wyd. 6 z dnia 21.07.2023 r.","methodology_zh":"沙门氏菌与志贺氏菌检出与鉴定","search_zh":"沙门氏菌与志贺氏菌检出与鉴定 M/PB-01 wyd. 6 z dnia 21.07.2023 r."},{"_id":"6a5dc9b9f1c10c8ce825d7db","lab_id":"69ad52a3de79e566650fb326","country":"PL","accr_number":"AB 616","accr_body":"PCA","test_object":"Biologiczne wskaźniki kontroli skuteczności sterylizacji","test_object_en":"Biological indicators for the control of sterilization efficacy","methodology":"Obecność drobnoustroju wskaźnikowego (Geobacillus stearothermophillus)","methodology_en":"Presence of the indicator microorganism (Geobacillus stearothermophillus)","parameters":[],"parameters_en":[],"technique":"Metoda hodowlana","techniques":["Metoda hodowlana"],"technique_en":"Culture method","computed":[],"computed_en":[],"activity":"Obecność drobnoustroju wskaźnikowego (Geobacillus stearothermophillus)\nMetoda hodowlana","reference":"M/PB-02 wyd. 4 z dnia 21.07.2023 r.","norm_bases":["M/PB-02 wyd. 4 z dnia 21.07.2023 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Biologiczne wskaźniki kontroli skuteczności sterylizacji Obecność drobnoustroju wskaźnikowego (Geobacillus stearothermophillus)\nMetoda hodowlana M/PB-02 wyd. 4 z dnia 21.07.2023 r. Biologiczne wskazniki kontroli skutecznosci sterylizacji Obecnosc drobnoustroju wskaznikowego (Geobacillus stearothermophillus)\nMetoda hodowlana M/PB-02 wyd. 4 z dnia 21.07.2023 r.","categories":["microbiology"],"row_index":42,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Biological indicators for the control of sterilization efficacy Presence of the indicator microorganism (Geobacillus stearothermophillus) Culture method M/PB-02 wyd. 4 z dnia 21.07.2023 r.","search_zh":"灭菌效果监测用生物指示物 培养法 M/PB-02 wyd. 4 z dnia 21.07.2023 r.","technique_zh":"培养法","test_object_zh":"灭菌效果监测用生物指示物"}],"has_pdf":true}