{"lab":{"_id":"69ad52a3de79e566650fb30c","accr_number":"AB 598","country":"PL","accr_body":"PCA","address":"Z SIEDZIBĄ W SIEDLCACH, ul. Kazimierzowska 29, 08-110 Siedlce, ZAKŁAD HIGIENY WETERYNARYJNEJ W WARSZAWIE, ul. Lechicka 21","categories":["food","microbiology","environment"],"city":"Siedlce","imported_at":"2026-03-08T10:42:43.265Z","methods_count":94,"name":"WOJEWÓDZKI INSPEKTORAT WETERYNARII","parse_status":"parsed","parse_version":3,"pdf_files":["AB_598.pdf"],"scope_summary":"","search_text":"wojewódzki inspektorat weterynarii z siedzibą w siedlcach, ul. kazimierzowska 29, 08-110 siedlce, zakład higieny weterynaryjnej w warszawie, ul. lechicka 21 other microbiology food pharma environment electronics water materials construction","status":"active","updated_at":"2026-03-08T14:51:29.548Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:29.548Z","location":{"type":"Point","coordinates":[22.2902,52.1676]},"email_confidence":"high","email_mx":true,"email_source":"https://www.pca.gov.pl/akredytowane-podmioty/akredytacje-aktywne/laboratoria-badawcze/AB%20598,podmiot.html","fields_of_testing":[{"codes":"B/3; B/22; B/55; B/57","pl":"Badania biologiczne i biochemiczne obiektów i materiałów biologicznych przeznaczonych do badań, żywności, pasz dla zwierząt, obiektów z obszaru produkcji żywności","en":"Biological and biochemical tests of biological items and materials for testing, food, animal feedstuffs, objects from food production area"},{"codes":"C/3; C/22; C/28","pl":"Badania chemiczne obiektów i materiałów biologicznych przeznaczonych do badań, żywności, wody","en":"Chemical tests of biological items and materials for testing, food, water"},{"codes":"D/3","pl":"Badania kliniczne, medyczne i weterynaryjne obiektów i materiałów biologicznych przeznaczonych do badań","en":"Clinical, medical and veterinary tests of biological items and materials for testing"},{"codes":"K/3; K/22; K/28; K/55; K/57","pl":"Badania mikrobiologiczne obiektów i materiałów biologicznych przeznaczonych do badań, żywności, wody, pasz dla zwierząt, obiektów z obszaru produkcji żywności","en":"Microbiological tests of biological items and materials for testing, food, water, animal feedstuffs, objects from food production area,"},{"codes":"N/22","pl":"Badania właściwości fizycznych żywności","en":"Tests of physical properties of food"},{"codes":"O/22","pl":"Badania radiochemiczne i promieniowania w tym nuklearne żywności","en":"Radiochemical tests and tests of radiation – including nuclear radiation of food"}],"parse_date":"2026-07-20T19:34:27.261Z","parse_source":"script-pdfplumber","map_coord":[52.175402,22.301308],"map_geo":"nominatim-street","has_en":true,"category_counts":{"food":67,"other":21,"microbiology":14,"environment":8,"water":4,"materials":3,"pharma":2,"construction":1},"category_scores":{"food":37.41,"other":3.68,"microbiology":1.63,"environment":0.53,"water":0.13,"materials":0.08,"pharma":0.03,"construction":0.01},"has_zh":true},"methods":[{"_id":"6a5e78434cc76d93cba3acc4","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Mleko i produkty mleczne, Mięso i produkty mięsne","test_object_en":"Milk and dairy products, Meat and meat products","methodology":"Liczba gronkowców koagulazododatnich","methodology_en":"Coagulase-positive staphylococci count","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"technique_en":"Plate method (pour plate)","computed":[],"computed_en":[],"activity":"Liczba gronkowców koagulazododatnich\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6888 – 2:2022-03 +A1:2024-02","norm_bases":["PN-EN ISO 6888 – 2:2022-03 +A1:2024-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mleko i produkty mleczne, Mięso i produkty mięsne Liczba gronkowców koagulazododatnich\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6888 – 2:2022-03 +A1:2024-02 Mleko i produkty mleczne, Mieso i produkty miesne Liczba gronkowcow koagulazododatnich\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6888 – 2:2022-03 +A1:2024-02","categories":["food"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Milk and dairy products, Meat and meat products Coagulase-positive staphylococci count Plate method (pour plate) PN-EN ISO 6888 – 2:2022-03 +A1:2024-02","search_zh":"乳与乳制品、肉与肉制品 凝固酶阳性葡萄球菌计数 平板法（倾注培养） PN-EN ISO 6888 – 2:2022-03 +A1:2024-02","technique_zh":"平板法（倾注培养）","methodology_zh":"凝固酶阳性葡萄球菌计数","test_object_zh":"乳与乳制品、肉与肉制品"},{"_id":"6a5e78434cc76d93cba3acc5","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Próbki środowiskowe z obszaru produkcji i obrotu żywnością oraz pasz 1)","test_object_en":"Environmental samples from the food and feed production and trade area 1)","methodology":"Ogólna liczba drobnoustrojów","methodology_en":"Total viable count","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"technique_en":"Plate method (pour plate)","computed":[],"computed_en":[],"activity":"Ogólna liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 4833 2)","norm_bases":["PN-EN ISO 4833 2)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Próbki środowiskowe z obszaru produkcji i obrotu żywnością oraz pasz 1) Ogólna liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 4833 2) Probki srodowiskowe z obszaru produkcji i obrotu zywnoscia oraz pasz 1) Ogolna liczba drobnoustrojow\nMetoda plytkowa (posiew wglebny) PN-EN ISO 4833 2)","categories":["food","environment","microbiology"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Environmental samples from the food and feed production and trade area 1) Total viable count Plate method (pour plate) PN-EN ISO 4833 2)","methodology_zh":"微生物总数","search_zh":"来自食品与饲料生产及流通领域的环境样品 1) 微生物总数 平板法（倾注培养） PN-EN ISO 4833 2)","technique_zh":"平板法（倾注培养）","test_object_zh":"来自食品与饲料生产及流通领域的环境样品 1)"},{"_id":"6a5e78434cc76d93cba3acc6","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Próbki środowiskowe z obszaru produkcji i obrotu żywnością oraz pasz 1)","test_object_en":"Environmental samples from the food and feed production and trade area 1)","methodology":"Liczba Enterobacteriaceae","methodology_en":"Enterobacteriaceae count","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"technique_en":"Plate method (pour plate)","computed":[],"computed_en":[],"activity":"Liczba Enterobacteriaceae\nMetoda płytkowa (posiew wgłębny)","reference":"PN-ISO 21528 2)","norm_bases":["PN-ISO 21528 2)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Próbki środowiskowe z obszaru produkcji i obrotu żywnością oraz pasz 1) Liczba Enterobacteriaceae\nMetoda płytkowa (posiew wgłębny) PN-ISO 21528 2) Probki srodowiskowe z obszaru produkcji i obrotu zywnoscia oraz pasz 1) Liczba Enterobacteriaceae\nMetoda plytkowa (posiew wglebny) PN-ISO 21528 2)","categories":["food","environment"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Environmental samples from the food and feed production and trade area 1) Enterobacteriaceae count Plate method (pour plate) PN-ISO 21528 2)","methodology_zh":"肠杆菌科（Enterobacteriaceae）计数","search_zh":"来自食品与饲料生产及流通领域的环境样品 1) 肠杆菌科（Enterobacteriaceae）计数 平板法（倾注培养） PN-ISO 21528 2)","technique_zh":"平板法（倾注培养）","test_object_zh":"来自食品与饲料生产及流通领域的环境样品 1)"},{"_id":"6a5e78434cc76d93cba3acc7","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Próbki środowiskowe z obszaru produkcji i obrotu żywnością oraz pasz 1)","test_object_en":"Environmental samples from the food and feed production and trade area 1)","methodology":"Obecność Salmonella spp.","methodology_en":"Presence of Salmonella spp.","parameters":[],"parameters_en":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"technique_en":"Culture method with biochemical and serological confirmation","computed":[],"computed_en":[],"activity":"Obecność Salmonella spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PN-EN ISO 6579 2)","norm_bases":["PN-EN ISO 6579 2)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Próbki środowiskowe z obszaru produkcji i obrotu żywnością oraz pasz 1) Obecność Salmonella spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579 2) Probki srodowiskowe z obszaru produkcji i obrotu zywnoscia oraz pasz 1) Obecnosc Salmonella spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579 2)","categories":["microbiology","food","environment"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Environmental samples from the food and feed production and trade area 1) Presence of Salmonella spp. Culture method with biochemical and serological confirmation PN-EN ISO 6579 2)","methodology_zh":"沙门氏菌属（Salmonella spp.）的检出","search_zh":"来自食品与饲料生产及流通领域的环境样品 1) 沙门氏菌属（Salmonella spp.）的检出 培养法结合生化与血清学确认 PN-EN ISO 6579 2)","technique_zh":"培养法结合生化与血清学确认","test_object_zh":"来自食品与饲料生产及流通领域的环境样品 1)"},{"_id":"6a5e78434cc76d93cba3acc8","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Próbki środowiskowe z obszaru produkcji i obrotu żywnością oraz pasz 1)","test_object_en":"Environmental samples from the food and feed production and trade area 1)","methodology":"Obecność Listeria monocytogenes","methodology_en":"Presence of Listeria monocytogenes","parameters":[],"parameters_en":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym"],"technique_en":"Culture method with biochemical confirmation","computed":[],"computed_en":[],"activity":"Obecność Listeria monocytogenes\nMetoda hodowlana z potwierdzeniem biochemicznym","reference":"PN-EN ISO 11290 2)","norm_bases":["PN-EN ISO 11290 2)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Próbki środowiskowe z obszaru produkcji i obrotu żywnością oraz pasz 1) Obecność Listeria monocytogenes\nMetoda hodowlana z potwierdzeniem biochemicznym PN-EN ISO 11290 2) Probki srodowiskowe z obszaru produkcji i obrotu zywnoscia oraz pasz 1) Obecnosc Listeria monocytogenes\nMetoda hodowlana z potwierdzeniem biochemicznym PN-EN ISO 11290 2)","categories":["food","environment","microbiology"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Environmental samples from the food and feed production and trade area 1) Presence of Listeria monocytogenes Culture method with biochemical confirmation PN-EN ISO 11290 2)","search_zh":"来自食品与饲料生产及流通领域的环境样品 1) 单核细胞增生李斯特氏菌的检出 培养法结合生化确认 PN-EN ISO 11290 2)","technique_zh":"培养法结合生化确认","methodology_zh":"单核细胞增生李斯特氏菌的检出","test_object_zh":"来自食品与饲料生产及流通领域的环境样品 1)"},{"_id":"6a5e78434cc76d93cba3acc9","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Próbki środowiskowe z obszaru produkcji i obrotu żywnością oraz pasz 1)","test_object_en":"Environmental samples from the food and feed production and trade area 1)","methodology":"Obecność Campylobacter spp.","methodology_en":"Presence of Campylobacter spp.","parameters":[],"parameters_en":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i mikroskopowym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i mikroskopowym"],"technique_en":"Culture method with biochemical and microscopic confirmation","computed":[],"computed_en":[],"activity":"Obecność Campylobacter spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i mikroskopowym","reference":"PN-EN ISO 10272 2)","norm_bases":["PN-EN ISO 10272 2)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Próbki środowiskowe z obszaru produkcji i obrotu żywnością oraz pasz 1) Obecność Campylobacter spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i mikroskopowym PN-EN ISO 10272 2) Probki srodowiskowe z obszaru produkcji i obrotu zywnoscia oraz pasz 1) Obecnosc Campylobacter spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i mikroskopowym PN-EN ISO 10272 2)","categories":["food","environment"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Environmental samples from the food and feed production and trade area 1) Presence of Campylobacter spp. Culture method with biochemical and microscopic confirmation PN-EN ISO 10272 2)","search_zh":"来自食品与饲料生产及流通领域的环境样品 1) 弯曲杆菌属的检出 培养法（附生化与显微确证） PN-EN ISO 10272 2)","technique_zh":"培养法（附生化与显微确证）","methodology_zh":"弯曲杆菌属的检出","test_object_zh":"来自食品与饲料生产及流通领域的环境样品 1)"},{"_id":"6a5e78434cc76d93cba3acca","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Próbki środowiskowe z obszaru produkcji i obrotu żywnością oraz pasz 1)","test_object_en":"Environmental samples from the food and feed production and trade area 1)","methodology":"Liczba Campylobacter spp.","methodology_en":"Campylobacter spp. count","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda płytkowa (posiew powierzchniowy)"],"technique_en":"Plate method (spread plate)","computed":[],"computed_en":[],"activity":"Liczba Campylobacter spp.\nMetoda płytkowa (posiew powierzchniowy)","reference":"PN-EN ISO 10272 2)","norm_bases":["PN-EN ISO 10272 2)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Próbki środowiskowe z obszaru produkcji i obrotu żywnością oraz pasz 1) Liczba Campylobacter spp.\nMetoda płytkowa (posiew powierzchniowy) PN-EN ISO 10272 2) Probki srodowiskowe z obszaru produkcji i obrotu zywnoscia oraz pasz 1) Liczba Campylobacter spp.\nMetoda plytkowa (posiew powierzchniowy) PN-EN ISO 10272 2)","categories":["food","environment"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Environmental samples from the food and feed production and trade area 1) Campylobacter spp. count Plate method (spread plate) PN-EN ISO 10272 2)","search_zh":"来自食品与饲料生产及流通领域的环境样品 1) 弯曲杆菌属计数 平板法（表面涂布） PN-EN ISO 10272 2)","technique_zh":"平板法（表面涂布）","methodology_zh":"弯曲杆菌属计数","test_object_zh":"来自食品与饲料生产及流通领域的环境样品 1)"},{"_id":"6a5e78434cc76d93cba3accb","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Żywność 1)","test_object_en":"Food 1)","methodology":"Liczba Enterobacteriaceae","methodology_en":"Enterobacteriaceae count","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"technique_en":"Plate method (pour plate)","computed":[],"computed_en":[],"activity":"Liczba Enterobacteriaceae\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 21528 2)","norm_bases":["PN-EN ISO 21528 2)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Żywność 1) Liczba Enterobacteriaceae\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 21528 2) Zywnosc 1) Liczba Enterobacteriaceae\nMetoda plytkowa (posiew wglebny) PN-EN ISO 21528 2)","categories":["food"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Food 1) Enterobacteriaceae count Plate method (pour plate) PN-EN ISO 21528 2)","methodology_zh":"肠杆菌科（Enterobacteriaceae）计数","search_zh":"食品 1) 肠杆菌科（Enterobacteriaceae）计数 平板法（倾注培养） PN-EN ISO 21528 2)","technique_zh":"平板法（倾注培养）","test_object_zh":"食品 1)"},{"_id":"6a5e78434cc76d93cba3accc","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Żywność 1)","test_object_en":"Food 1)","methodology":"Ogólna liczba drobnoustrojów","methodology_en":"Total viable count","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"technique_en":"Plate method (pour plate)","computed":[],"computed_en":[],"activity":"Ogólna liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 4833 2)","norm_bases":["PN-EN ISO 4833 2)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Żywność 1) Ogólna liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 4833 2) Zywnosc 1) Ogolna liczba drobnoustrojow\nMetoda plytkowa (posiew wglebny) PN-EN ISO 4833 2)","categories":["food","microbiology"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Food 1) Total viable count Plate method (pour plate) PN-EN ISO 4833 2)","methodology_zh":"微生物总数","search_zh":"食品 1) 微生物总数 平板法（倾注培养） PN-EN ISO 4833 2)","technique_zh":"平板法（倾注培养）","test_object_zh":"食品 1)"},{"_id":"6a5e78434cc76d93cba3accd","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Żywność 1)","test_object_en":"Food 1)","methodology":"Liczba gronkowców koagulazododatnich","methodology_en":"Coagulase-positive staphylococci count","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda płytkowa (posiew powierzchniowy)"],"technique_en":"Plate method (spread plate)","computed":[],"computed_en":[],"activity":"Liczba gronkowców koagulazododatnich\nMetoda płytkowa (posiew powierzchniowy)","reference":"PN-EN ISO 6888 2)","norm_bases":["PN-EN ISO 6888 2)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Żywność 1) Liczba gronkowców koagulazododatnich\nMetoda płytkowa (posiew powierzchniowy) PN-EN ISO 6888 2) Zywnosc 1) Liczba gronkowcow koagulazododatnich\nMetoda plytkowa (posiew powierzchniowy) PN-EN ISO 6888 2)","categories":["food"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Food 1) Coagulase-positive staphylococci count Plate method (spread plate) PN-EN ISO 6888 2)","search_zh":"食品 1) 凝固酶阳性葡萄球菌计数 平板法（表面涂布） PN-EN ISO 6888 2)","technique_zh":"平板法（表面涂布）","test_object_zh":"食品 1)","methodology_zh":"凝固酶阳性葡萄球菌计数"},{"_id":"6a5e78434cc76d93cba3acce","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Żywność 1)","test_object_en":"Food 1)","methodology":"Liczba β-glukuronidazo-dodatnich, E.coli","methodology_en":"Count of β-glucuronidase-positive, E.coli","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"technique_en":"Plate method (pour plate)","computed":[],"computed_en":[],"activity":"Liczba β-glukuronidazo-dodatnich, E.coli\nMetoda płytkowa (posiew wgłębny)","reference":"PN-ISO 16649 2)","norm_bases":["PN-ISO 16649 2)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Żywność 1) Liczba β-glukuronidazo-dodatnich, E.coli\nMetoda płytkowa (posiew wgłębny) PN-ISO 16649 2) Zywnosc 1) Liczba β-glukuronidazo-dodatnich, E.coli\nMetoda plytkowa (posiew wglebny) PN-ISO 16649 2)","categories":["food"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Food 1) Count of β-glucuronidase-positive, E.coli Plate method (pour plate) PN-ISO 16649 2)","search_zh":"食品 1) 平板法（倾注培养） PN-ISO 16649 2)","technique_zh":"平板法（倾注培养）","test_object_zh":"食品 1)"},{"_id":"6a5e78434cc76d93cba3accf","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Żywność 1)","test_object_en":"Food 1)","methodology":"Obecność Salmonella spp.","methodology_en":"Presence of Salmonella spp.","parameters":[],"parameters_en":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"technique_en":"Culture method with biochemical and serological confirmation","computed":[],"computed_en":[],"activity":"Obecność Salmonella spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PN-EN ISO 6579 2)","norm_bases":["PN-EN ISO 6579 2)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Żywność 1) Obecność Salmonella spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579 2) Zywnosc 1) Obecnosc Salmonella spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579 2)","categories":["microbiology","food"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Food 1) Presence of Salmonella spp. Culture method with biochemical and serological confirmation PN-EN ISO 6579 2)","methodology_zh":"沙门氏菌属（Salmonella spp.）的检出","search_zh":"食品 1) 沙门氏菌属（Salmonella spp.）的检出 培养法结合生化与血清学确认 PN-EN ISO 6579 2)","technique_zh":"培养法结合生化与血清学确认","test_object_zh":"食品 1)"},{"_id":"6a5e78434cc76d93cba3acd0","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Żywność 1)","test_object_en":"Food 1)","methodology":"Liczba Listeria monocytogenes","methodology_en":"Listeria monocytogenes count","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda płytkowa (posiew powierzchniowy)"],"technique_en":"Plate method (spread plate)","computed":[],"computed_en":[],"activity":"Liczba Listeria monocytogenes\nMetoda płytkowa (posiew powierzchniowy)","reference":"PN-EN ISO 11290 2)","norm_bases":["PN-EN ISO 11290 2)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Żywność 1) Liczba Listeria monocytogenes\nMetoda płytkowa (posiew powierzchniowy) PN-EN ISO 11290 2) Zywnosc 1) Liczba Listeria monocytogenes\nMetoda plytkowa (posiew powierzchniowy) PN-EN ISO 11290 2)","categories":["food","microbiology"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Food 1) Listeria monocytogenes count Plate method (spread plate) PN-EN ISO 11290 2)","search_zh":"食品 1) 单核细胞增生李斯特氏菌计数 平板法（表面涂布） PN-EN ISO 11290 2)","technique_zh":"平板法（表面涂布）","test_object_zh":"食品 1)","methodology_zh":"单核细胞增生李斯特氏菌计数"},{"_id":"6a5e78434cc76d93cba3acd1","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Żywność 1)","test_object_en":"Food 1)","methodology":"Obecność Listeria monocytogenes","methodology_en":"Presence of Listeria monocytogenes","parameters":[],"parameters_en":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym"],"technique_en":"Culture method with biochemical confirmation","computed":[],"computed_en":[],"activity":"Obecność Listeria monocytogenes\nMetoda hodowlana z potwierdzeniem biochemicznym","reference":"PN-EN ISO 11290 2)","norm_bases":["PN-EN ISO 11290 2)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Żywność 1) Obecność Listeria monocytogenes\nMetoda hodowlana z potwierdzeniem biochemicznym PN-EN ISO 11290 2) Zywnosc 1) Obecnosc Listeria monocytogenes\nMetoda hodowlana z potwierdzeniem biochemicznym PN-EN ISO 11290 2)","categories":["food","microbiology"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Food 1) Presence of Listeria monocytogenes Culture method with biochemical confirmation PN-EN ISO 11290 2)","search_zh":"食品 1) 单核细胞增生李斯特氏菌的检出 培养法结合生化确认 PN-EN ISO 11290 2)","technique_zh":"培养法结合生化确认","test_object_zh":"食品 1)","methodology_zh":"单核细胞增生李斯特氏菌的检出"},{"_id":"6a5e78434cc76d93cba3acd2","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Żywność 1)","test_object_en":"Food 1)","methodology":"Obecność Campylobacter spp.","methodology_en":"Presence of Campylobacter spp.","parameters":[],"parameters_en":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i mikroskopowym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i mikroskopowym"],"technique_en":"Culture method with biochemical and microscopic confirmation","computed":[],"computed_en":[],"activity":"Obecność Campylobacter spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i mikroskopowym","reference":"PN-EN ISO 10272 2)","norm_bases":["PN-EN ISO 10272 2)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Żywność 1) Obecność Campylobacter spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i mikroskopowym PN-EN ISO 10272 2) Zywnosc 1) Obecnosc Campylobacter spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i mikroskopowym PN-EN ISO 10272 2)","categories":["food"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Food 1) Presence of Campylobacter spp. Culture method with biochemical and microscopic confirmation PN-EN ISO 10272 2)","search_zh":"食品 1) 弯曲杆菌属的检出 培养法（附生化与显微确证） PN-EN ISO 10272 2)","test_object_zh":"食品 1)","technique_zh":"培养法（附生化与显微确证）","methodology_zh":"弯曲杆菌属的检出"},{"_id":"6a5e78434cc76d93cba3acd3","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Żywność 1)","test_object_en":"Food 1)","methodology":"Liczba Campylobacter spp.","methodology_en":"Campylobacter spp. count","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda płytkowa (posiew powierzchniowy)"],"technique_en":"Plate method (spread plate)","computed":[],"computed_en":[],"activity":"Liczba Campylobacter spp.\nMetoda płytkowa (posiew powierzchniowy)","reference":"PN-EN ISO 10272 2)","norm_bases":["PN-EN ISO 10272 2)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Żywność 1) Liczba Campylobacter spp.\nMetoda płytkowa (posiew powierzchniowy) PN-EN ISO 10272 2) Zywnosc 1) Liczba Campylobacter spp.\nMetoda plytkowa (posiew powierzchniowy) PN-EN ISO 10272 2)","categories":["food"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Food 1) Campylobacter spp. count Plate method (spread plate) PN-EN ISO 10272 2)","search_zh":"食品 1) 弯曲杆菌属计数 平板法（表面涂布） PN-EN ISO 10272 2)","technique_zh":"平板法（表面涂布）","test_object_zh":"食品 1)","methodology_zh":"弯曲杆菌属计数"},{"_id":"6a5e78434cc76d93cba3acd4","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Żywność 1)","test_object_en":"Food 1)","methodology":"Obecność enterotoksyn gronkowcowych, Metoda enzymo–immunofluorescencyjna (ELFA)","methodology_en":"Presence of staphylococcal enterotoxins, Enzyme–linked fluorescent immunoassay (ELFA)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Obecność enterotoksyn gronkowcowych, Metoda enzymo–immunofluorescencyjna (ELFA)","reference":"PN-EN ISO 19020 z wyłączeniem pkt.11 2) | Instrukcja Vidas Staph Enterotoxin II (SET2) 2)","norm_bases":["PN-EN ISO 19020 z wyłączeniem pkt.11 2)","Instrukcja Vidas Staph Enterotoxin II (SET2) 2)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Żywność 1) Obecność enterotoksyn gronkowcowych, Metoda enzymo–immunofluorescencyjna (ELFA) PN-EN ISO 19020 z wyłączeniem pkt.11 2) | Instrukcja Vidas Staph Enterotoxin II (SET2) 2) Zywnosc 1) Obecnosc enterotoksyn gronkowcowych, Metoda enzymo–immunofluorescencyjna (ELFA) PN-EN ISO 19020 z wylaczeniem pkt.11 2) | Instrukcja Vidas Staph Enterotoxin II (SET2) 2)","categories":["food"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Food 1) Presence of staphylococcal enterotoxins, Enzyme–linked fluorescent immunoassay (ELFA) PN-EN ISO 19020 z wyłączeniem pkt.11 2) | Instrukcja Vidas Staph Enterotoxin II (SET2) 2)","search_zh":"食品 1) PN-EN ISO 19020 z wyłączeniem pkt.11 2) | Instrukcja Vidas Staph Enterotoxin II (SET2) 2)","test_object_zh":"食品 1)"},{"_id":"6a5e78434cc76d93cba3acd5","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Surowe mięso drobiowe","test_object_en":"Raw poultry meat","methodology":"Obecność i identyfikacja Salmonella spp.","methodology_en":"Presence and identification of Salmonella spp.","parameters":[],"parameters_en":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"technique_en":"Culture method with biochemical and serological confirmation","computed":[],"computed_en":[],"activity":"Obecność i identyfikacja Salmonella spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PN-EN ISO 6579 2) Schemat White’a - Kauffmanna – Le Minora2)","norm_bases":["PN-EN ISO 6579 2) Schemat White’a - Kauffmanna – Le Minora2)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Surowe mięso drobiowe Obecność i identyfikacja Salmonella spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579 2) Schemat White’a - Kauffmanna – Le Minora2) Surowe mieso drobiowe Obecnosc i identyfikacja Salmonella spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579 2) Schemat White’a - Kauffmanna – Le Minora2)","categories":["microbiology","food"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Raw poultry meat Presence and identification of Salmonella spp. Culture method with biochemical and serological confirmation PN-EN ISO 6579 2) Schemat White’a - Kauffmanna – Le Minora2)","search_zh":"沙门氏菌属的检出与鉴定 培养法结合生化与血清学确认 PN-EN ISO 6579 2) Schemat White’a - Kauffmanna – Le Minora2)","technique_zh":"培养法结合生化与血清学确认","methodology_zh":"沙门氏菌属的检出与鉴定"},{"_id":"6a5e78434cc76d93cba3acd6","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Mleko surowe","test_object_en":"Raw milk","methodology":"Obecność pozostałości antybiotyków i innych substancji przeciwbakteryjnych","methodology_en":"Presence of residues of antibiotics and other antibacterial substances","parameters":[],"parameters_en":[],"technique":"Metoda dyfuzyjna DELVOTEST","techniques":["Metoda dyfuzyjna DELVOTEST"],"technique_en":"DELVOTEST diffusion method","computed":[],"computed_en":[],"activity":"Obecność pozostałości antybiotyków i innych substancji przeciwbakteryjnych\nMetoda dyfuzyjna DELVOTEST","reference":"PB-03/MŻ | na podstawie instrukcji testu DELVOTEST SP NT 3)","norm_bases":["PB-03/MŻ","na podstawie instrukcji testu DELVOTEST SP NT 3)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mleko surowe Obecność pozostałości antybiotyków i innych substancji przeciwbakteryjnych\nMetoda dyfuzyjna DELVOTEST PB-03/MŻ | na podstawie instrukcji testu DELVOTEST SP NT 3) Mleko surowe Obecnosc pozostalosci antybiotykow i innych substancji przeciwbakteryjnych\nMetoda dyfuzyjna DELVOTEST PB-03/MZ | na podstawie instrukcji testu DELVOTEST SP NT 3)","categories":["food"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Raw milk Presence of residues of antibiotics and other antibacterial substances DELVOTEST diffusion method PB-03/MŻ | na podstawie instrukcji testu DELVOTEST SP NT 3)","search_zh":"生乳 抗生素与其他抗菌物质残留的检出 PB-03/MŻ | na podstawie instrukcji testu DELVOTEST SP NT 3)","test_object_zh":"生乳","methodology_zh":"抗生素与其他抗菌物质残留的检出"},{"_id":"6a5e78434cc76d93cba3acd7","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Mleko surowe","test_object_en":"Raw milk","methodology":"Obecność pozostałości antybiotyków β–laktamowych, dihydrostreptomycyny, streptomycyny, chloramfenikolu i tetracyklin","methodology_en":"Presence of residues of β–lactam antibiotics, dihydrostreptomycin, streptomycin, chloramphenicol and tetracyclines","parameters":[],"parameters_en":[],"technique":"Metoda receptorowa 4-Sensor","techniques":["Metoda receptorowa 4-Sensor"],"technique_en":"Receptor method 4-Sensor","computed":[],"computed_en":[],"activity":"Obecność pozostałości antybiotyków β–laktamowych, dihydrostreptomycyny, streptomycyny, chloramfenikolu i tetracyklin\nMetoda receptorowa 4-Sensor","reference":"PB-08/MŻ | na podstawie instrukcji testu 4-Sensor 3)","norm_bases":["PB-08/MŻ","na podstawie instrukcji testu 4-Sensor 3)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mleko surowe Obecność pozostałości antybiotyków β–laktamowych, dihydrostreptomycyny, streptomycyny, chloramfenikolu i tetracyklin\nMetoda receptorowa 4-Sensor PB-08/MŻ | na podstawie instrukcji testu 4-Sensor 3) Mleko surowe Obecnosc pozostalosci antybiotykow β–laktamowych, dihydrostreptomycyny, streptomycyny, chloramfenikolu i tetracyklin\nMetoda receptorowa 4-Sensor PB-08/MZ | na podstawie instrukcji testu 4-Sensor 3)","categories":["food"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Raw milk Presence of residues of β–lactam antibiotics, dihydrostreptomycin, streptomycin, chloramphenicol and tetracyclines Receptor method 4-Sensor PB-08/MŻ | na podstawie instrukcji testu 4-Sensor 3)","search_zh":"生乳 PB-08/MŻ | na podstawie instrukcji testu 4-Sensor 3)","test_object_zh":"生乳"},{"_id":"6a5e78434cc76d93cba3acd8","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Tkanki zwierzęce, Jaja, Woda dla zwierząt","test_object_en":"Animal tissues, Eggs, Water for animals","methodology":"Obecność pozostałości substancji przeciwbakteryjnych z grupy B1","methodology_en":"Presence of residues of antibacterial substances of group B1","parameters":[],"parameters_en":[],"technique":"Metoda dyfuzyjna, 5-płytkowa","techniques":["Metoda dyfuzyjna, 5-płytkowa"],"technique_en":"Diffusion method, 5-plate","computed":[],"computed_en":[],"activity":"Obecność pozostałości substancji przeciwbakteryjnych z grupy B1\nMetoda dyfuzyjna, 5-płytkowa","reference":"PB-06/MŻ | na podstawie Instrukcji PIW- PIB Puławy z 2011 r. 3)","norm_bases":["PB-06/MŻ","na podstawie Instrukcji PIW- PIB Puławy z 2011 r. 3)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Tkanki zwierzęce, Jaja, Woda dla zwierząt Obecność pozostałości substancji przeciwbakteryjnych z grupy B1\nMetoda dyfuzyjna, 5-płytkowa PB-06/MŻ | na podstawie Instrukcji PIW- PIB Puławy z 2011 r. 3) Tkanki zwierzece, Jaja, Woda dla zwierzat Obecnosc pozostalosci substancji przeciwbakteryjnych z grupy B1\nMetoda dyfuzyjna, 5-plytkowa PB-06/MZ | na podstawie Instrukcji PIW- PIB Pulawy z 2011 r. 3)","categories":["water","food"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Animal tissues, Eggs, Water for animals Presence of residues of antibacterial substances of group B1 Diffusion method, 5-plate PB-06/MŻ | na podstawie Instrukcji PIW- PIB Puławy z 2011 r. 3)"},{"_id":"6a5e78434cc76d93cba3acd9","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Pasze","test_object_en":"Feed","methodology":"Liczba Enterobacteriaceae","methodology_en":"Enterobacteriaceae count","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"technique_en":"Plate method (pour plate)","computed":[],"computed_en":[],"activity":"Liczba Enterobacteriaceae\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 21528 2)","norm_bases":["PN-EN ISO 21528 2)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pasze Liczba Enterobacteriaceae\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 21528 2) Pasze Liczba Enterobacteriaceae\nMetoda plytkowa (posiew wglebny) PN-EN ISO 21528 2)","categories":["food"],"row_index":21,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Feed Enterobacteriaceae count Plate method (pour plate) PN-EN ISO 21528 2)","methodology_zh":"肠杆菌科（Enterobacteriaceae）计数","search_zh":"饲料 肠杆菌科（Enterobacteriaceae）计数 平板法（倾注培养） PN-EN ISO 21528 2)","technique_zh":"平板法（倾注培养）","test_object_zh":"饲料"},{"_id":"6a5e78434cc76d93cba3acda","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Pasze","test_object_en":"Feed","methodology":"Ogólna liczba drobnoustrojów","methodology_en":"Total viable count","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"technique_en":"Plate method (pour plate)","computed":[],"computed_en":[],"activity":"Ogólna liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 4833 2)","norm_bases":["PN-EN ISO 4833 2)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pasze Ogólna liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 4833 2) Pasze Ogolna liczba drobnoustrojow\nMetoda plytkowa (posiew wglebny) PN-EN ISO 4833 2)","categories":["food","microbiology"],"row_index":22,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Feed Total viable count Plate method (pour plate) PN-EN ISO 4833 2)","methodology_zh":"微生物总数","search_zh":"饲料 微生物总数 平板法（倾注培养） PN-EN ISO 4833 2)","technique_zh":"平板法（倾注培养）","test_object_zh":"饲料"},{"_id":"6a5e78434cc76d93cba3acdb","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Pasze","test_object_en":"Feed","methodology":"Obecność Salmonella spp.","methodology_en":"Presence of Salmonella spp.","parameters":[],"parameters_en":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"technique_en":"Culture method with biochemical and serological confirmation","computed":[],"computed_en":[],"activity":"Obecność Salmonella spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PN-EN ISO 6579 2)","norm_bases":["PN-EN ISO 6579 2)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pasze Obecność Salmonella spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579 2) Pasze Obecnosc Salmonella spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579 2)","categories":["microbiology","food"],"row_index":23,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Feed Presence of Salmonella spp. Culture method with biochemical and serological confirmation PN-EN ISO 6579 2)","methodology_zh":"沙门氏菌属（Salmonella spp.）的检出","search_zh":"饲料 沙门氏菌属（Salmonella spp.）的检出 培养法结合生化与血清学确认 PN-EN ISO 6579 2)","technique_zh":"培养法结合生化与血清学确认","test_object_zh":"饲料"},{"_id":"6a5e78434cc76d93cba3acdc","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Pasze, Tłuszcz","test_object_en":"Feed, Fat","methodology":"Obecność składników pochodzenia zwierzęcego","methodology_en":"Presence of components of animal origin","parameters":[],"parameters_en":[],"technique":"Metoda mikroskopowa","techniques":["Metoda mikroskopowa"],"technique_en":"Microscopic method","computed":[],"computed_en":[],"activity":"Obecność składników pochodzenia zwierzęcego\nMetoda mikroskopowa","reference":"Rozporządzenie wykonawcze Komisji (UE) 2022/893 z dnia 7 czerwca 2022 r. zmieniające załącznik VI do rozporządzenia (WE) nr 152/2009 w odniesieniu do metod analizy dotyczących wykrywania składników pochodzących z bezkręgowców lądowych do celów urzędowej kontroli pasz","norm_bases":["Rozporządzenie wykonawcze Komisji (UE) 2022/893 z dnia 7 czerwca 2022 r. zmieniające załącznik VI do rozporządzenia (WE) nr 152/2009 w odniesieniu do metod analizy dotyczących wykrywania składników pochodzących z bezkręgowców lądowych do celów urzędowej kontroli pasz"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pasze, Tłuszcz Obecność składników pochodzenia zwierzęcego\nMetoda mikroskopowa Rozporządzenie wykonawcze Komisji (UE) 2022/893 z dnia 7 czerwca 2022 r. zmieniające załącznik VI do rozporządzenia (WE) nr 152/2009 w odniesieniu do metod analizy dotyczących wykrywania składników pochodzących z bezkręgowców lądowych do celów urzędowej kontroli pasz Pasze, Tluszcz Obecnosc skladnikow pochodzenia zwierzecego\nMetoda mikroskopowa Rozporzadzenie wykonawcze Komisji (UE) 2022/893 z dnia 7 czerwca 2022 r. zmieniajace zalacznik VI do rozporzadzenia (WE) nr 152/2009 w odniesieniu do metod analizy dotyczacych wykrywania skladnikow pochodzacych z bezkregowcow ladowych do celow urzedowej kontroli pasz","categories":["food"],"row_index":24,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Feed, Fat Presence of components of animal origin Microscopic method Rozporządzenie wykonawcze Komisji (UE) 2022/893 z dnia 7 czerwca 2022 r. zmieniające załącznik VI do rozporządzenia (WE) nr 152/2009 w odniesieniu do metod analizy dotyczących wykrywania składników pochodzących z bezkręgowców lądowych do celów urzędowej kontroli pasz","search_zh":"动物源成分的检出 显微镜法 Rozporządzenie wykonawcze Komisji (UE) 2022/893 z dnia 7 czerwca 2022 r. zmieniające załącznik VI do rozporządzenia (WE) nr 152/2009 w odniesieniu do metod analizy dotyczących wykrywania składników pochodzących z bezkręgowców lądowych do celów urzędowej kontroli pasz","technique_zh":"显微镜法","methodology_zh":"动物源成分的检出"},{"_id":"6a5e78434cc76d93cba3acdd","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Pasze, Ziarna zbóż przeznaczonych na cele paszowe","test_object_en":"Feed, Cereal grains intended for feed purposes","methodology":"Obecność szkodników żywych","methodology_en":"Presence of live pests","parameters":[],"parameters_en":[],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"technique_en":"Visual method","computed":[],"computed_en":[],"activity":"Obecność szkodników żywych\nMetoda wizualna","reference":"PB-03/MP wydanie 04 z dnia 14.11.2024 r.","norm_bases":["PB-03/MP wydanie 04 z dnia 14.11.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pasze, Ziarna zbóż przeznaczonych na cele paszowe Obecność szkodników żywych\nMetoda wizualna PB-03/MP wydanie 04 z dnia 14.11.2024 r. Pasze, Ziarna zboz przeznaczonych na cele paszowe Obecnosc szkodnikow zywych\nMetoda wizualna PB-03/MP wydanie 04 z dnia 14.11.2024 r.","categories":["food"],"row_index":25,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Feed, Cereal grains intended for feed purposes Presence of live pests Visual method PB-03/MP wydanie 04 z dnia 14.11.2024 r.","search_zh":"活虫害的检出 目视法 PB-03/MP wydanie 04 z dnia 14.11.2024 r.","technique_zh":"目视法","methodology_zh":"活虫害的检出"},{"_id":"6a5e78434cc76d93cba3acde","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Pasze, Ziarna zbóż przeznaczonych na cele paszowe","test_object_en":"Feed, Cereal grains intended for feed purposes","methodology":"Zawartość zanieczyszczeń botanicznych w paszach","methodology_en":"Content of botanical impurities in feed","parameters":[{"name":"od 1 mg/kg"}],"parameters_en":[{"name":"from 1 mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość zanieczyszczeń botanicznych w paszach\nod 1 mg/kg\nMetoda wagowa","reference":"PB-02/MP wydanie 03 z dnia 14.11.2024 r.","norm_bases":["PB-02/MP wydanie 03 z dnia 14.11.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pasze, Ziarna zbóż przeznaczonych na cele paszowe Zawartość zanieczyszczeń botanicznych w paszach\nod 1 mg/kg\nMetoda wagowa PB-02/MP wydanie 03 z dnia 14.11.2024 r. Pasze, Ziarna zboz przeznaczonych na cele paszowe Zawartosc zanieczyszczen botanicznych w paszach\nod 1 mg/kg\nMetoda wagowa PB-02/MP wydanie 03 z dnia 14.11.2024 r.","categories":["food"],"row_index":26,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Feed, Cereal grains intended for feed purposes Content of botanical impurities in feed Gravimetric method from 1 mg/kg PB-02/MP wydanie 03 z dnia 14.11.2024 r.","search_zh":"重量法 PB-02/MP wydanie 03 z dnia 14.11.2024 r.","technique_zh":"重量法"},{"_id":"6a5e78434cc76d93cba3acdf","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością – wymazy, wycinki z powierzchni ograniczonej szablonem, Mięso i produkty mięsne, Mleko i produkty mleczne, Pasze","test_object_en":"Environmental samples from food production and distribution areas – swabs, excised samples from an area delimited by a template, Meat and meat products, Milk and milk products, Feed","methodology":"Obecność DNA Salmonella spp.","methodology_en":"Presence of Salmonella spp. DNA","parameters":[],"parameters_en":[],"technique":"Metoda real - time PCR","techniques":["Metoda real - time PCR"],"technique_en":"Real - time PCR method","computed":[],"computed_en":[],"activity":"Obecność DNA Salmonella spp.\nMetoda real - time PCR","reference":"PB-01/PCR wydanie 03 z dnia 12.11.2024 r.","norm_bases":["PB-01/PCR wydanie 03 z dnia 12.11.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością – wymazy, wycinki z powierzchni ograniczonej szablonem, Mięso i produkty mięsne, Mleko i produkty mleczne, Pasze Obecność DNA Salmonella spp.\nMetoda real - time PCR PB-01/PCR wydanie 03 z dnia 12.11.2024 r. Probki srodowiskowe z obszarow produkcji zywnosci i obrotu zywnoscia – wymazy, wycinki z powierzchni ograniczonej szablonem, Mieso i produkty miesne, Mleko i produkty mleczne, Pasze Obecnosc DNA Salmonella spp.\nMetoda real - time PCR PB-01/PCR wydanie 03 z dnia 12.11.2024 r.","categories":["food","microbiology","environment"],"row_index":27,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Environmental samples from food production and distribution areas – swabs, excised samples from an area delimited by a template, Meat and meat products, Milk and milk products, Feed Presence of Salmonella spp. DNA Real - time PCR method PB-01/PCR wydanie 03 z dnia 12.11.2024 r.","methodology_zh":"沙门氏菌属（Salmonella spp.）DNA 的检出","search_zh":"沙门氏菌属（Salmonella spp.）DNA 的检出 实时荧光定量 PCR 法 PB-01/PCR wydanie 03 z dnia 12.11.2024 r.","technique_zh":"实时荧光定量 PCR 法"},{"_id":"6a5e78434cc76d93cba3ace0","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością – wymazy, Mięso i produkty mięsne, Mleko i produkty mleczne, Ryby przetwory rybne, Wyroby garmażeryjne","test_object_en":"Environmental samples from food production and distribution areas – swabs, Meat and meat products, Milk and milk products, Fish fish products, Delicatessen products","methodology":"Obecność DNA Listeria monocytogenes","methodology_en":"Presence of Listeria monocytogenes DNA","parameters":[],"parameters_en":[],"technique":"Metoda real - time PCR","techniques":["Metoda real - time PCR"],"technique_en":"Real - time PCR method","computed":[],"computed_en":[],"activity":"Obecność DNA Listeria monocytogenes\nMetoda real - time PCR","reference":"PB-02/PCR wydanie 02 z dnia 13.11.2024 r.","norm_bases":["PB-02/PCR wydanie 02 z dnia 13.11.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością – wymazy, Mięso i produkty mięsne, Mleko i produkty mleczne, Ryby przetwory rybne, Wyroby garmażeryjne Obecność DNA Listeria monocytogenes\nMetoda real - time PCR PB-02/PCR wydanie 02 z dnia 13.11.2024 r. Probki srodowiskowe z obszarow produkcji zywnosci i obrotu zywnoscia – wymazy, Mieso i produkty miesne, Mleko i produkty mleczne, Ryby przetwory rybne, Wyroby garmazeryjne Obecnosc DNA Listeria monocytogenes\nMetoda real - time PCR PB-02/PCR wydanie 02 z dnia 13.11.2024 r.","categories":["food","environment","microbiology"],"row_index":28,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Environmental samples from food production and distribution areas – swabs, Meat and meat products, Milk and milk products, Fish fish products, Delicatessen products Presence of Listeria monocytogenes DNA Real - time PCR method PB-02/PCR wydanie 02 z dnia 13.11.2024 r.","methodology_zh":"单核细胞增生李斯特氏菌 DNA 的检出","search_zh":"单核细胞增生李斯特氏菌 DNA 的检出 实时荧光定量 PCR 法 PB-02/PCR wydanie 02 z dnia 13.11.2024 r.","technique_zh":"实时荧光定量 PCR 法"},{"_id":"6a5e78434cc76d93cba3ace1","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Mięso surowe świń i dzików","test_object_en":"Raw meat of pigs and wild boars","methodology":"Obecność włośni (Trichinella) metoda wytrawiania próbki zbiorczej z zastosowaniem metody magnetycznego mieszania","methodology_en":"Presence of trichinae (Trichinella) magnetic stirring method of digestion of a pooled sample","parameters":[],"parameters_en":[],"technique":"Metoda referencyjna","techniques":["Metoda referencyjna"],"technique_en":"Reference method","computed":[],"computed_en":[],"activity":"Obecność włośni (Trichinella) metoda wytrawiania próbki zbiorczej z zastosowaniem metody magnetycznego mieszania\nMetoda referencyjna","reference":"PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2)","norm_bases":["PN-EN ISO 18743 1)","Instrukcja Głównego Lekarza Weterynarii 2)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mięso surowe świń i dzików Obecność włośni (Trichinella) metoda wytrawiania próbki zbiorczej z zastosowaniem metody magnetycznego mieszania\nMetoda referencyjna PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2) Mieso surowe swin i dzikow Obecnosc wlosni (Trichinella) metoda wytrawiania probki zbiorczej z zastosowaniem metody magnetycznego mieszania\nMetoda referencyjna PN-EN ISO 18743 1) | Instrukcja Glownego Lekarza Weterynarii 2)","categories":["food"],"row_index":29,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Raw meat of pigs and wild boars Presence of trichinae (Trichinella) magnetic stirring method of digestion of a pooled sample Reference method PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2)","search_zh":"猪和野猪生肉 旋毛虫（Trichinella）的检出 混合样品磁力搅拌消化法 基准方法 PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2)","technique_zh":"基准方法","test_object_zh":"猪和野猪生肉","methodology_zh":"旋毛虫（Trichinella）的检出 混合样品磁力搅拌消化法"},{"_id":"6a5e78434cc76d93cba3ace2","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Mięso surowe świń","test_object_en":"Raw meat of pigs","methodology":"Obecność włośni (Trichinella) metoda wytrawiania próbki zbiorczej z zastosowaniem metody magnetycznego mieszania","methodology_en":"Presence of trichinae (Trichinella) magnetic stirring method of digestion of a pooled sample","parameters":[],"parameters_en":[],"technique":"Metoda referencyjna","techniques":["Metoda referencyjna"],"technique_en":"Reference method","computed":[],"computed_en":[],"activity":"Obecność włośni (Trichinella) metoda wytrawiania próbki zbiorczej z zastosowaniem metody magnetycznego mieszania\nMetoda referencyjna","reference":"PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2)","norm_bases":["PN-EN ISO 18743 1)","Instrukcja Głównego Lekarza Weterynarii 2)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mięso surowe świń Obecność włośni (Trichinella) metoda wytrawiania próbki zbiorczej z zastosowaniem metody magnetycznego mieszania\nMetoda referencyjna PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2) Mieso surowe swin Obecnosc wlosni (Trichinella) metoda wytrawiania probki zbiorczej z zastosowaniem metody magnetycznego mieszania\nMetoda referencyjna PN-EN ISO 18743 1) | Instrukcja Glownego Lekarza Weterynarii 2)","categories":["food"],"row_index":30,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Raw meat of pigs Presence of trichinae (Trichinella) magnetic stirring method of digestion of a pooled sample Reference method PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2)","search_zh":"猪生肉 旋毛虫（Trichinella）的检出 混合样品磁力搅拌消化法 基准方法 PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2)","technique_zh":"基准方法","test_object_zh":"猪生肉","methodology_zh":"旋毛虫（Trichinella）的检出 混合样品磁力搅拌消化法"},{"_id":"6a5e78434cc76d93cba3ace3","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Mięso surowe świń i dzików","test_object_en":"Raw meat of pigs and wild boars","methodology":"Obecność włośni (Trichinella) metoda wytrawiania próbki zbiorczej z zastosowaniem metody magnetycznego mieszania","methodology_en":"Presence of trichinae (Trichinella) magnetic stirring method of digestion of a pooled sample","parameters":[],"parameters_en":[],"technique":"Metoda referencyjna","techniques":["Metoda referencyjna"],"technique_en":"Reference method","computed":[],"computed_en":[],"activity":"Obecność włośni (Trichinella) metoda wytrawiania próbki zbiorczej z zastosowaniem metody magnetycznego mieszania\nMetoda referencyjna","reference":"PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2)","norm_bases":["PN-EN ISO 18743 1)","Instrukcja Głównego Lekarza Weterynarii 2)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mięso surowe świń i dzików Obecność włośni (Trichinella) metoda wytrawiania próbki zbiorczej z zastosowaniem metody magnetycznego mieszania\nMetoda referencyjna PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2) Mieso surowe swin i dzikow Obecnosc wlosni (Trichinella) metoda wytrawiania probki zbiorczej z zastosowaniem metody magnetycznego mieszania\nMetoda referencyjna PN-EN ISO 18743 1) | Instrukcja Glownego Lekarza Weterynarii 2)","categories":["food"],"row_index":31,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Raw meat of pigs and wild boars Presence of trichinae (Trichinella) magnetic stirring method of digestion of a pooled sample Reference method PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2)","search_zh":"猪和野猪生肉 旋毛虫（Trichinella）的检出 混合样品磁力搅拌消化法 基准方法 PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2)","technique_zh":"基准方法","test_object_zh":"猪和野猪生肉","methodology_zh":"旋毛虫（Trichinella）的检出 混合样品磁力搅拌消化法"},{"_id":"6a5e78434cc76d93cba3ace4","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Mięso surowe świń","test_object_en":"Raw meat of pigs","methodology":"Obecność włośni (Trichinella) metoda wytrawiania próbki zbiorczej z zastosowaniem metody magnetycznego mieszania","methodology_en":"Presence of trichinae (Trichinella) magnetic stirring method of digestion of a pooled sample","parameters":[],"parameters_en":[],"technique":"Metoda referencyjna","techniques":["Metoda referencyjna"],"technique_en":"Reference method","computed":[],"computed_en":[],"activity":"Obecność włośni (Trichinella) metoda wytrawiania próbki zbiorczej z zastosowaniem metody magnetycznego mieszania\nMetoda referencyjna","reference":"PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2)","norm_bases":["PN-EN ISO 18743 1)","Instrukcja Głównego Lekarza Weterynarii 2)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mięso surowe świń Obecność włośni (Trichinella) metoda wytrawiania próbki zbiorczej z zastosowaniem metody magnetycznego mieszania\nMetoda referencyjna PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2) Mieso surowe swin Obecnosc wlosni (Trichinella) metoda wytrawiania probki zbiorczej z zastosowaniem metody magnetycznego mieszania\nMetoda referencyjna PN-EN ISO 18743 1) | Instrukcja Glownego Lekarza Weterynarii 2)","categories":["food"],"row_index":32,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Raw meat of pigs Presence of trichinae (Trichinella) magnetic stirring method of digestion of a pooled sample Reference method PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2)","search_zh":"猪生肉 旋毛虫（Trichinella）的检出 混合样品磁力搅拌消化法 基准方法 PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2)","technique_zh":"基准方法","test_object_zh":"猪生肉","methodology_zh":"旋毛虫（Trichinella）的检出 混合样品磁力搅拌消化法"},{"_id":"6a5e78434cc76d93cba3ace5","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Mięso surowe świń","test_object_en":"Raw meat of pigs","methodology":"Obecność włośni (Trichinella) metoda wytrawiania próbki zbiorczej z zastosowaniem metody magnetycznego mieszania","methodology_en":"Presence of trichinae (Trichinella) magnetic stirring method of digestion of a pooled sample","parameters":[],"parameters_en":[],"technique":"Metoda referencyjna","techniques":["Metoda referencyjna"],"technique_en":"Reference method","computed":[],"computed_en":[],"activity":"Obecność włośni (Trichinella) metoda wytrawiania próbki zbiorczej z zastosowaniem metody magnetycznego mieszania\nMetoda referencyjna","reference":"PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2)","norm_bases":["PN-EN ISO 18743 1)","Instrukcja Głównego Lekarza Weterynarii 2)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mięso surowe świń Obecność włośni (Trichinella) metoda wytrawiania próbki zbiorczej z zastosowaniem metody magnetycznego mieszania\nMetoda referencyjna PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2) Mieso surowe swin Obecnosc wlosni (Trichinella) metoda wytrawiania probki zbiorczej z zastosowaniem metody magnetycznego mieszania\nMetoda referencyjna PN-EN ISO 18743 1) | Instrukcja Glownego Lekarza Weterynarii 2)","categories":["food"],"row_index":33,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Raw meat of pigs Presence of trichinae (Trichinella) magnetic stirring method of digestion of a pooled sample Reference method PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2)","search_zh":"猪生肉 旋毛虫（Trichinella）的检出 混合样品磁力搅拌消化法 基准方法 PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2)","technique_zh":"基准方法","test_object_zh":"猪生肉","methodology_zh":"旋毛虫（Trichinella）的检出 混合样品磁力搅拌消化法"},{"_id":"6a5e78434cc76d93cba3ace6","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Mięso surowe świń","test_object_en":"Raw meat of pigs","methodology":"Obecność włośni (Trichinella) metoda wytrawiania próbki zbiorczej z zastosowaniem metody magnetycznego mieszania","methodology_en":"Presence of trichinae (Trichinella) magnetic stirring method of digestion of a pooled sample","parameters":[],"parameters_en":[],"technique":"Metoda referencyjna","techniques":["Metoda referencyjna"],"technique_en":"Reference method","computed":[],"computed_en":[],"activity":"Obecność włośni (Trichinella) metoda wytrawiania próbki zbiorczej z zastosowaniem metody magnetycznego mieszania\nMetoda referencyjna","reference":"PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2)","norm_bases":["PN-EN ISO 18743 1)","Instrukcja Głównego Lekarza Weterynarii 2)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mięso surowe świń Obecność włośni (Trichinella) metoda wytrawiania próbki zbiorczej z zastosowaniem metody magnetycznego mieszania\nMetoda referencyjna PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2) Mieso surowe swin Obecnosc wlosni (Trichinella) metoda wytrawiania probki zbiorczej z zastosowaniem metody magnetycznego mieszania\nMetoda referencyjna PN-EN ISO 18743 1) | Instrukcja Glownego Lekarza Weterynarii 2)","categories":["food"],"row_index":34,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Raw meat of pigs Presence of trichinae (Trichinella) magnetic stirring method of digestion of a pooled sample Reference method PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2)","search_zh":"猪生肉 旋毛虫（Trichinella）的检出 混合样品磁力搅拌消化法 基准方法 PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2)","technique_zh":"基准方法","test_object_zh":"猪生肉","methodology_zh":"旋毛虫（Trichinella）的检出 混合样品磁力搅拌消化法"},{"_id":"6a5e78434cc76d93cba3ace7","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Tkanka tłuszczowa, Ryby, Jaja (tłuszcz)","test_object_en":"Adipose tissue, Fish, Eggs (fat)","methodology":"Zawartość pestycydów chloroorganicznych","methodology_en":"Organochlorine pesticide content","parameters":[{"name":"Tkanka tłuszczowa: Aldryna","range":"(0,005-0,050) mg/kg"},{"name":"Dieldryna","range":"(0,005-0,050) mg/kg"},{"name":"Chlordan - cis (lambda)","range":"(0,005-0,050) mg/kg"},{"name":"Chlordan-trans (alfa)","range":"(0,005-0,050) mg/kg"},{"name":"Oksychlordan","range":"(0,005-0,050) mg/kg"},{"name":"pp”DDD","range":"(0,005-0,050) mg/kg"},{"name":"pp”DDE","range":"(0,005-0,050) mg/kg"},{"name":"pp”DDT","range":"(0,005-0,050) mg/kg"},{"name":"op” DDT","range":"(0,005-0,050) mg/kg"},{"name":"pp” DMD - (metoksychlor)","range":"(0,005-0,050) mg/kg"},{"name":"Endosulfan alfa","range":"(0,005-0,050) mg/kg"},{"name":"Endosulfan beta","range":"(0,005-0,050) mg/kg"},{"name":"Endosulfanu siarczan","range":"(0,005-0,050) mg/kg"},{"name":"Endryna","range":"(0,005-0,050) mg/kg"},{"name":"HCB","range":"(0,005-0,050) mg/kg"},{"name":"HCH - alfa","range":"(0,005-0,050) mg/kg"},{"name":"HCH - beta","range":"(0,005-0,050) mg/kg"},{"name":"HCH - gamma (lindan)","range":"(0,005-0,050) mg/kg"},{"name":"Cis – epoksyd heptachloru","range":"(0,005-0,050) mg/kg"},{"name":"Trans – epoksyd heptachloru","range":"(0,005-0,050) mg/kg"},{"name":"Heptachlor","range":"(0,005-0,050) mg/kg"},{"name":"Jaja (tłuszcz): Aldryna","range":"(0,005-0,050) mg/kg"},{"name":"Dieldryna","range":"(0,005-0,050) mg/kg"},{"name":"Chlordan - cis (lambda)","range":"(0,005-0,050) mg/kg"},{"name":"Chlordan-trans (alfa)","range":"(0,005-0,050) mg/kg"},{"name":"Oksychlordan","range":"(0,001-0,050) mg/kg"},{"name":"pp”DDD","range":"(0,005-0,050) mg/kg"},{"name":"pp”DDE","range":"(0,005-0,050) mg/kg"},{"name":"pp”DDT","range":"(0,005-0,050) mg/kg"},{"name":"op” DDT","range":"(0,005-0,050) mg/kg"},{"name":"pp” DMD - (metoksychlor)","range":"(0,005-0,050) mg/kg"},{"name":"Endosulfan alfa","range":"(0,005-0,050) mg/kg"},{"name":"Endosulfan beta","range":"(0,005-0,050) mg/kg"},{"name":"Endosulfanu siarczan","range":"(0,005-0,050) mg/kg"},{"name":"Endryna","range":"(0,005-0,050) mg/kg"},{"name":"HCB","range":"(0,005-0,050) mg/kg"},{"name":"HCH - alfa","range":"(0,005-0,050) mg/kg"},{"name":"HCH - beta","range":"(0,005-0,050) mg/kg"},{"name":"HCH - gamma (lindan)","range":"(0,005-0,050) mg/kg"},{"name":"Cis – epoksyd heptachloru","range":"(0,005-0,050) mg/kg"},{"name":"Trans – epoksyd heptachloru","range":"(0,005-0,050) mg/kg"},{"name":"Heptachlor","range":"(0,005-0,050) mg/kg"}],"parameters_en":[{"name":"Adipose tissue: Aldrin","range":"(0,005-0,050) mg/kg"},{"name":"Dieldrin","range":"(0,005-0,050) mg/kg"},{"name":"Chlordane - cis (lambda)","range":"(0,005-0,050) mg/kg"},{"name":"Chlordane-trans (alpha)","range":"(0,005-0,050) mg/kg"},{"name":"Oxychlordane","range":"(0,005-0,050) mg/kg"},{"name":"pp”DDD","range":"(0,005-0,050) mg/kg"},{"name":"pp”DDE","range":"(0,005-0,050) mg/kg"},{"name":"pp”DDT","range":"(0,005-0,050) mg/kg"},{"name":"op” DDT","range":"(0,005-0,050) mg/kg"},{"name":"pp” DMD - (methoxychlor)","range":"(0,005-0,050) mg/kg"},{"name":"Endosulfan alpha","range":"(0,005-0,050) mg/kg"},{"name":"Endosulfan beta","range":"(0,005-0,050) mg/kg"},{"name":"Endosulfan sulfate","range":"(0,005-0,050) mg/kg"},{"name":"Endrin","range":"(0,005-0,050) mg/kg"},{"name":"HCB","range":"(0,005-0,050) mg/kg"},{"name":"HCH - alpha","range":"(0,005-0,050) mg/kg"},{"name":"HCH - beta","range":"(0,005-0,050) mg/kg"},{"name":"HCH - gamma (lindane)","range":"(0,005-0,050) mg/kg"},{"name":"Cis – heptachlor epoxide","range":"(0,005-0,050) mg/kg"},{"name":"Trans – heptachlor epoxide","range":"(0,005-0,050) mg/kg"},{"name":"Heptachlor","range":"(0,005-0,050) mg/kg"},{"name":"Eggs (fat): Aldrin","range":"(0,005-0,050) mg/kg"},{"name":"Dieldrin","range":"(0,005-0,050) mg/kg"},{"name":"Chlordane - cis (lambda)","range":"(0,005-0,050) mg/kg"},{"name":"Chlordane-trans (alpha)","range":"(0,005-0,050) mg/kg"},{"name":"Oxychlordane","range":"(0,001-0,050) mg/kg"},{"name":"pp”DDD","range":"(0,005-0,050) mg/kg"},{"name":"pp”DDE","range":"(0,005-0,050) mg/kg"},{"name":"pp”DDT","range":"(0,005-0,050) mg/kg"},{"name":"op” DDT","range":"(0,005-0,050) mg/kg"},{"name":"pp” DMD - (methoxychlor)","range":"(0,005-0,050) mg/kg"},{"name":"Endosulfan alpha","range":"(0,005-0,050) mg/kg"},{"name":"Endosulfan beta","range":"(0,005-0,050) mg/kg"},{"name":"Endosulfan sulfate","range":"(0,005-0,050) mg/kg"},{"name":"Endrin","range":"(0,005-0,050) mg/kg"},{"name":"HCB","range":"(0,005-0,050) mg/kg"},{"name":"HCH - alpha","range":"(0,005-0,050) mg/kg"},{"name":"HCH - beta","range":"(0,005-0,050) mg/kg"},{"name":"HCH - gamma (lindane)","range":"(0,005-0,050) mg/kg"},{"name":"Cis – heptachlor epoxide","range":"(0,005-0,050) mg/kg"},{"name":"Trans – heptachlor epoxide","range":"(0,005-0,050) mg/kg"},{"name":"Heptachlor","range":"(0,005-0,050) mg/kg"}],"technique":"Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","techniques":["Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)"],"technique_en":"Gas chromatography with electron capture detection (GC-ECD)","computed":[],"computed_en":[],"activity":"Zawartość pestycydów chloroorganicznych\nZakres:\nTkanka tłuszczowa: Aldryna (0,005-0,050) mg/kg\nDieldryna (0,005-0,050) mg/kg\nChlordan - cis (lambda) (0,005-0,050) mg/kg\nChlordan-trans (alfa) (0,005-0,050) mg/kg\nOksychlordan (0,005-0,050) mg/kg\npp”DDD (0,005-0,050) mg/kg\npp”DDE (0,005-0,050) mg/kg\npp”DDT (0,005-0,050) mg/kg\nop” DDT (0,005-0,050) mg/kg\npp” DMD - (metoksychlor) (0,005-0,050) mg/kg\nEndosulfan alfa (0,005-0,050) mg/kg\nEndosulfan beta (0,005-0,050) mg/kg\nEndosulfanu siarczan (0,005-0,050) mg/kg\nEndryna (0,005-0,050) mg/kg\nHCB (0,005-0,050) mg/kg\nHCH - alfa (0,005-0,050) mg/kg\nHCH - beta (0,005-0,050) mg/kg\nHCH - gamma (lindan) (0,005-0,050) mg/kg\nCis – epoksyd heptachloru (0,005-0,050) mg/kg\nTrans – epoksyd heptachloru (0,005-0,050) mg/kg\nHeptachlor (0,005-0,050) mg/kg\nJaja (tłuszcz): Aldryna (0,005-0,050) mg/kg\nDieldryna (0,005-0,050) mg/kg\nChlordan - cis (lambda) (0,005-0,050) mg/kg\nChlordan-trans (alfa) (0,005-0,050) mg/kg\nOksychlordan (0,001-0,050) mg/kg\npp”DDD (0,005-0,050) mg/kg\npp”DDE (0,005-0,050) mg/kg\npp”DDT (0,005-0,050) mg/kg\nop” DDT (0,005-0,050) mg/kg\npp” DMD - (metoksychlor) (0,005-0,050) mg/kg\nEndosulfan alfa (0,005-0,050) mg/kg\nEndosulfan beta (0,005-0,050) mg/kg\nEndosulfanu siarczan (0,005-0,050) mg/kg\nEndryna (0,005-0,050) mg/kg\nHCB (0,005-0,050) mg/kg\nHCH - alfa (0,005-0,050) mg/kg\nHCH - beta (0,005-0,050) mg/kg\nHCH - gamma (lindan) (0,005-0,050) mg/kg\nCis – epoksyd heptachloru (0,005-0,050) mg/kg\nTrans – epoksyd heptachloru (0,005-0,050) mg/kg\nHeptachlor (0,005-0,050) mg/kg\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","reference":"P B - 0 1/CHŻ wydanie 08 z dnia 25.07.2024 r.","norm_bases":["P B - 0 1/CHŻ wydanie 08 z dnia 25.07.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Tkanka tłuszczowa, Ryby, Jaja (tłuszcz) Zawartość pestycydów chloroorganicznych\nZakres:\nTkanka tłuszczowa: Aldryna (0,005-0,050) mg/kg\nDieldryna (0,005-0,050) mg/kg\nChlordan - cis (lambda) (0,005-0,050) mg/kg\nChlordan-trans (alfa) (0,005-0,050) mg/kg\nOksychlordan (0,005-0,050) mg/kg\npp”DDD (0,005-0,050) mg/kg\npp”DDE (0,005-0,050) mg/kg\npp”DDT (0,005-0,050) mg/kg\nop” DDT (0,005-0,050) mg/kg\npp” DMD - (metoksychlor) (0,005-0,050) mg/kg\nEndosulfan alfa (0,005-0,050) mg/kg\nEndosulfan beta (0,005-0,050) mg/kg\nEndosulfanu siarczan (0,005-0,050) mg/kg\nEndryna (0,005-0,050) mg/kg\nHCB (0,005-0,050) mg/kg\nHCH - alfa (0,005-0,050) mg/kg\nHCH - beta (0,005-0,050) mg/kg\nHCH - gamma (lindan) (0,005-0,050) mg/kg\nCis – epoksyd heptachloru (0,005-0,050) mg/kg\nTrans – epoksyd heptachloru (0,005-0,050) mg/kg\nHeptachlor (0,005-0,050) mg/kg\nJaja (tłuszcz): Aldryna (0,005-0,050) mg/kg\nDieldryna (0,005-0,050) mg/kg\nChlordan - cis (lambda) (0,005-0,050) mg/kg\nChlordan-trans (alfa) (0,005-0,050) mg/kg\nOksychlordan (0,001-0,050) mg/kg\npp”DDD (0,005-0,050) mg/kg\npp”DDE (0,005-0,050) mg/kg\npp”DDT (0,005-0,050) mg/kg\nop” DDT (0,005-0,050) mg/kg\npp” DMD - (metoksychlor) (0,005-0,050) mg/kg\nEndosulfan alfa (0,005-0,050) mg/kg\nEndosulfan beta (0,005-0,050) mg/kg\nEndosulfanu siarczan (0,005-0,050) mg/kg\nEndryna (0,005-0,050) mg/kg\nHCB (0,005-0,050) mg/kg\nHCH - alfa (0,005-0,050) mg/kg\nHCH - beta (0,005-0,050) mg/kg\nHCH - gamma (lindan) (0,005-0,050) mg/kg\nCis – epoksyd heptachloru (0,005-0,050) mg/kg\nTrans – epoksyd heptachloru (0,005-0,050) mg/kg\nHeptachlor (0,005-0,050) mg/kg\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) P B - 0 1/CHŻ wydanie 08 z dnia 25.07.2024 r. Tkanka tluszczowa, Ryby, Jaja (tluszcz) Zawartosc pestycydow chloroorganicznych\nZakres:\nTkanka tluszczowa: Aldryna (0,005-0,050) mg/kg\nDieldryna (0,005-0,050) mg/kg\nChlordan - cis (lambda) (0,005-0,050) mg/kg\nChlordan-trans (alfa) (0,005-0,050) mg/kg\nOksychlordan (0,005-0,050) mg/kg\npp”DDD (0,005-0,050) mg/kg\npp”DDE (0,005-0,050) mg/kg\npp”DDT (0,005-0,050) mg/kg\nop” DDT (0,005-0,050) mg/kg\npp” DMD - (metoksychlor) (0,005-0,050) mg/kg\nEndosulfan alfa (0,005-0,050) mg/kg\nEndosulfan beta (0,005-0,050) mg/kg\nEndosulfanu siarczan (0,005-0,050) mg/kg\nEndryna (0,005-0,050) mg/kg\nHCB (0,005-0,050) mg/kg\nHCH - alfa (0,005-0,050) mg/kg\nHCH - beta (0,005-0,050) mg/kg\nHCH - gamma (lindan) (0,005-0,050) mg/kg\nCis – epoksyd heptachloru (0,005-0,050) mg/kg\nTrans – epoksyd heptachloru (0,005-0,050) mg/kg\nHeptachlor (0,005-0,050) mg/kg\nJaja (tluszcz): Aldryna (0,005-0,050) mg/kg\nDieldryna (0,005-0,050) mg/kg\nChlordan - cis (lambda) (0,005-0,050) mg/kg\nChlordan-trans (alfa) (0,005-0,050) mg/kg\nOksychlordan (0,001-0,050) mg/kg\npp”DDD (0,005-0,050) mg/kg\npp”DDE (0,005-0,050) mg/kg\npp”DDT (0,005-0,050) mg/kg\nop” DDT (0,005-0,050) mg/kg\npp” DMD - (metoksychlor) (0,005-0,050) mg/kg\nEndosulfan alfa (0,005-0,050) mg/kg\nEndosulfan beta (0,005-0,050) mg/kg\nEndosulfanu siarczan (0,005-0,050) mg/kg\nEndryna (0,005-0,050) mg/kg\nHCB (0,005-0,050) mg/kg\nHCH - alfa (0,005-0,050) mg/kg\nHCH - beta (0,005-0,050) mg/kg\nHCH - gamma (lindan) (0,005-0,050) mg/kg\nCis – epoksyd heptachloru (0,005-0,050) mg/kg\nTrans – epoksyd heptachloru (0,005-0,050) mg/kg\nHeptachlor (0,005-0,050) mg/kg\nMetoda chromatografii gazowej z detekcja wychwytu elektronow (GC-ECD) P B - 0 1/CHZ wydanie 08 z dnia 25.07.2024 r.","categories":["food"],"row_index":35,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Adipose tissue, Fish, Eggs (fat) Organochlorine pesticide content Gas chromatography with electron capture detection (GC-ECD) Adipose tissue: Aldrin Dieldrin Chlordane - cis (lambda) Chlordane-trans (alpha) Oxychlordane pp”DDD pp”DDE pp”DDT op” DDT pp” DMD - (methoxychlor) Endosulfan alpha Endosulfan beta Endosulfan sulfate Endrin HCB HCH - alpha HCH - beta HCH - gamma (lindane) Cis – heptachlor epoxide Trans – heptachlor epoxide Heptachlor Eggs (fat): Aldrin Dieldrin Chlordane - cis (lambda) Chlordane-trans (alpha) Oxychlordane pp”DDD pp”DDE pp”DDT op” DDT pp” DMD - (methoxychlor) Endosulfan alpha Endosulfan beta Endosulfan sulfate Endrin HCB HCH - alpha HCH - beta HCH - gamma (lindane) Cis – heptachlor epoxide Trans – heptachlor epoxide Heptachlor P B - 0 1/CHŻ wydanie 08 z dnia 25.07.2024 r.","search_zh":"有机氯农药含量 气相色谱-电子捕获检测法（GC-ECD） 狄氏剂 氧化氯丹 异狄氏剂 六氯苯（HCB） 七氯 狄氏剂 氧化氯丹 异狄氏剂 六氯苯（HCB） 七氯 P B - 0 1/CHŻ wydanie 08 z dnia 25.07.2024 r.","technique_zh":"气相色谱-电子捕获检测法（GC-ECD）","parameters_zh":[{"name":"Tkanka tłuszczowa: Aldryna","range":"(0,005-0,050) mg/kg"},{"name":"狄氏剂","range":"(0,005-0,050) mg/kg"},{"name":"Chlordan - cis (lambda)","range":"(0,005-0,050) mg/kg"},{"name":"Chlordan-trans (alfa)","range":"(0,005-0,050) mg/kg"},{"name":"氧化氯丹","range":"(0,005-0,050) mg/kg"},{"name":"pp”DDD","range":"(0,005-0,050) mg/kg"},{"name":"pp”DDE","range":"(0,005-0,050) mg/kg"},{"name":"pp”DDT","range":"(0,005-0,050) mg/kg"},{"name":"op” DDT","range":"(0,005-0,050) mg/kg"},{"name":"pp” DMD - (metoksychlor)","range":"(0,005-0,050) mg/kg"},{"name":"Endosulfan alfa","range":"(0,005-0,050) mg/kg"},{"name":"Endosulfan beta","range":"(0,005-0,050) mg/kg"},{"name":"Endosulfanu siarczan","range":"(0,005-0,050) mg/kg"},{"name":"异狄氏剂","range":"(0,005-0,050) mg/kg"},{"name":"六氯苯（HCB）","range":"(0,005-0,050) mg/kg"},{"name":"HCH - alfa","range":"(0,005-0,050) mg/kg"},{"name":"HCH - beta","range":"(0,005-0,050) mg/kg"},{"name":"HCH - gamma (lindan)","range":"(0,005-0,050) mg/kg"},{"name":"Cis – epoksyd heptachloru","range":"(0,005-0,050) mg/kg"},{"name":"Trans – epoksyd heptachloru","range":"(0,005-0,050) mg/kg"},{"name":"七氯","range":"(0,005-0,050) mg/kg"},{"name":"Jaja (tłuszcz): Aldryna","range":"(0,005-0,050) mg/kg"},{"name":"狄氏剂","range":"(0,005-0,050) mg/kg"},{"name":"Chlordan - cis (lambda)","range":"(0,005-0,050) mg/kg"},{"name":"Chlordan-trans (alfa)","range":"(0,005-0,050) mg/kg"},{"name":"氧化氯丹","range":"(0,001-0,050) mg/kg"},{"name":"pp”DDD","range":"(0,005-0,050) mg/kg"},{"name":"pp”DDE","range":"(0,005-0,050) mg/kg"},{"name":"pp”DDT","range":"(0,005-0,050) mg/kg"},{"name":"op” DDT","range":"(0,005-0,050) mg/kg"},{"name":"pp” DMD - (metoksychlor)","range":"(0,005-0,050) mg/kg"},{"name":"Endosulfan alfa","range":"(0,005-0,050) mg/kg"},{"name":"Endosulfan beta","range":"(0,005-0,050) mg/kg"},{"name":"Endosulfanu siarczan","range":"(0,005-0,050) mg/kg"},{"name":"异狄氏剂","range":"(0,005-0,050) mg/kg"},{"name":"六氯苯（HCB）","range":"(0,005-0,050) mg/kg"},{"name":"HCH - alfa","range":"(0,005-0,050) mg/kg"},{"name":"HCH - beta","range":"(0,005-0,050) mg/kg"},{"name":"HCH - gamma (lindan)","range":"(0,005-0,050) mg/kg"},{"name":"Cis – epoksyd heptachloru","range":"(0,005-0,050) mg/kg"},{"name":"Trans – epoksyd heptachloru","range":"(0,005-0,050) mg/kg"},{"name":"七氯","range":"(0,005-0,050) mg/kg"}],"methodology_zh":"有机氯农药含量"},{"_id":"6a5e78434cc76d93cba3ace8","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Tkanka tłuszczowa, Ryby, Jaja (tłuszcz)","test_object_en":"Adipose tissue, Fish, Eggs (fat)","methodology":"Zawartość pestycydów chloroorganicznych","methodology_en":"Organochlorine pesticide content","parameters":[{"name":"Ryby: Aldryna","range":"(0,005-0,050) mg/kg"},{"name":"Dieldryna","range":"(0,005-0,050) mg/kg"},{"name":"Chlordan - cis (lambda)","range":"(0,005-0,050) mg/kg"},{"name":"Chlordan-trans (alfa)","range":"(0,005-0,050) mg/kg"},{"name":"Oksychlordan","range":"(0,005-0,050) mg/kg"},{"name":"pp”DDD","range":"(0,005-0,050) mg/kg"},{"name":"pp”DDE","range":"(0,005-0,050) mg/kg"},{"name":"pp”DDT","range":"(0,005-0,050) mg/kg"},{"name":"op” DDT","range":"(0,005-0,050) mg/kg"},{"name":"pp” DMD - (metoksychlor)","range":"(0,005-0,050) mg/kg"},{"name":"Endosulfan alfa","range":"(0,005-0,050) mg/kg"},{"name":"Endosulfan beta","range":"(0,005-0,050) mg/kg"},{"name":"Endosulfanu siarczan","range":"(0,005-0,050) mg/kg"},{"name":"Endryna","range":"(0,005-0,050) mg/kg"},{"name":"HCB","range":"(0,005-0,050) mg/kg"},{"name":"HCH - alfa","range":"(0,005-0,050) mg/kg"},{"name":"HCH - beta","range":"(0,005-0,050) mg/kg"},{"name":"HCH - gamma (lindan)","range":"(0,005-0,050) mg/kg"},{"name":"Cis – epoksyd heptachloru","range":"(0,005-0,050) mg/kg"},{"name":"Trans – epoksyd heptachloru","range":"(0,005-0,050) mg/kg"},{"name":"Heptachlor","range":"(0,005-0,050) mg/kg"}],"parameters_en":[{"name":"Fish: Aldrin","range":"(0,005-0,050) mg/kg"},{"name":"Dieldrin","range":"(0,005-0,050) mg/kg"},{"name":"Chlordane - cis (lambda)","range":"(0,005-0,050) mg/kg"},{"name":"Chlordane-trans (alpha)","range":"(0,005-0,050) mg/kg"},{"name":"Oxychlordane","range":"(0,005-0,050) mg/kg"},{"name":"pp”DDD","range":"(0,005-0,050) mg/kg"},{"name":"pp”DDE","range":"(0,005-0,050) mg/kg"},{"name":"pp”DDT","range":"(0,005-0,050) mg/kg"},{"name":"op” DDT","range":"(0,005-0,050) mg/kg"},{"name":"pp” DMD - (methoxychlor)","range":"(0,005-0,050) mg/kg"},{"name":"Endosulfan alpha","range":"(0,005-0,050) mg/kg"},{"name":"Endosulfan beta","range":"(0,005-0,050) mg/kg"},{"name":"Endosulfan sulfate","range":"(0,005-0,050) mg/kg"},{"name":"Endrin","range":"(0,005-0,050) mg/kg"},{"name":"HCB","range":"(0,005-0,050) mg/kg"},{"name":"HCH - alpha","range":"(0,005-0,050) mg/kg"},{"name":"HCH - beta","range":"(0,005-0,050) mg/kg"},{"name":"HCH - gamma (lindane)","range":"(0,005-0,050) mg/kg"},{"name":"Cis – heptachlor epoxide","range":"(0,005-0,050) mg/kg"},{"name":"Trans – heptachlor epoxide","range":"(0,005-0,050) mg/kg"},{"name":"Heptachlor","range":"(0,005-0,050) mg/kg"}],"technique":"Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","techniques":["Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)"],"technique_en":"Gas chromatography with electron capture detection (GC-ECD)","computed":[],"computed_en":[],"activity":"Zawartość pestycydów chloroorganicznych\nZakres:\nRyby: Aldryna (0,005-0,050) mg/kg\nDieldryna (0,005-0,050) mg/kg\nChlordan - cis (lambda) (0,005-0,050) mg/kg\nChlordan-trans (alfa) (0,005-0,050) mg/kg\nOksychlordan (0,005-0,050) mg/kg\npp”DDD (0,005-0,050) mg/kg\npp”DDE (0,005-0,050) mg/kg\npp”DDT (0,005-0,050) mg/kg\nop” DDT (0,005-0,050) mg/kg\npp” DMD - (metoksychlor) (0,005-0,050) mg/kg\nEndosulfan alfa (0,005-0,050) mg/kg\nEndosulfan beta (0,005-0,050) mg/kg\nEndosulfanu siarczan (0,005-0,050) mg/kg\nEndryna (0,005-0,050) mg/kg\nHCB (0,005-0,050) mg/kg\nHCH - alfa (0,005-0,050) mg/kg\nHCH - beta (0,005-0,050) mg/kg\nHCH - gamma (lindan) (0,005-0,050) mg/kg\nCis – epoksyd heptachloru (0,005-0,050) mg/kg\nTrans – epoksyd heptachloru (0,005-0,050) mg/kg\nHeptachlor (0,005-0,050) mg/kg\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","reference":"P B - 0 1/CHŻ wydanie 08 z dnia 25.07.2024 r.","norm_bases":["P B - 0 1/CHŻ wydanie 08 z dnia 25.07.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Tkanka tłuszczowa, Ryby, Jaja (tłuszcz) Zawartość pestycydów chloroorganicznych\nZakres:\nRyby: Aldryna (0,005-0,050) mg/kg\nDieldryna (0,005-0,050) mg/kg\nChlordan - cis (lambda) (0,005-0,050) mg/kg\nChlordan-trans (alfa) (0,005-0,050) mg/kg\nOksychlordan (0,005-0,050) mg/kg\npp”DDD (0,005-0,050) mg/kg\npp”DDE (0,005-0,050) mg/kg\npp”DDT (0,005-0,050) mg/kg\nop” DDT (0,005-0,050) mg/kg\npp” DMD - (metoksychlor) (0,005-0,050) mg/kg\nEndosulfan alfa (0,005-0,050) mg/kg\nEndosulfan beta (0,005-0,050) mg/kg\nEndosulfanu siarczan (0,005-0,050) mg/kg\nEndryna (0,005-0,050) mg/kg\nHCB (0,005-0,050) mg/kg\nHCH - alfa (0,005-0,050) mg/kg\nHCH - beta (0,005-0,050) mg/kg\nHCH - gamma (lindan) (0,005-0,050) mg/kg\nCis – epoksyd heptachloru (0,005-0,050) mg/kg\nTrans – epoksyd heptachloru (0,005-0,050) mg/kg\nHeptachlor (0,005-0,050) mg/kg\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) P B - 0 1/CHŻ wydanie 08 z dnia 25.07.2024 r. Tkanka tluszczowa, Ryby, Jaja (tluszcz) Zawartosc pestycydow chloroorganicznych\nZakres:\nRyby: Aldryna (0,005-0,050) mg/kg\nDieldryna (0,005-0,050) mg/kg\nChlordan - cis (lambda) (0,005-0,050) mg/kg\nChlordan-trans (alfa) (0,005-0,050) mg/kg\nOksychlordan (0,005-0,050) mg/kg\npp”DDD (0,005-0,050) mg/kg\npp”DDE (0,005-0,050) mg/kg\npp”DDT (0,005-0,050) mg/kg\nop” DDT (0,005-0,050) mg/kg\npp” DMD - (metoksychlor) (0,005-0,050) mg/kg\nEndosulfan alfa (0,005-0,050) mg/kg\nEndosulfan beta (0,005-0,050) mg/kg\nEndosulfanu siarczan (0,005-0,050) mg/kg\nEndryna (0,005-0,050) mg/kg\nHCB (0,005-0,050) mg/kg\nHCH - alfa (0,005-0,050) mg/kg\nHCH - beta (0,005-0,050) mg/kg\nHCH - gamma (lindan) (0,005-0,050) mg/kg\nCis – epoksyd heptachloru (0,005-0,050) mg/kg\nTrans – epoksyd heptachloru (0,005-0,050) mg/kg\nHeptachlor (0,005-0,050) mg/kg\nMetoda chromatografii gazowej z detekcja wychwytu elektronow (GC-ECD) P B - 0 1/CHZ wydanie 08 z dnia 25.07.2024 r.","categories":["food"],"row_index":36,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Adipose tissue, Fish, Eggs (fat) Organochlorine pesticide content Gas chromatography with electron capture detection (GC-ECD) Fish: Aldrin Dieldrin Chlordane - cis (lambda) Chlordane-trans (alpha) Oxychlordane pp”DDD pp”DDE pp”DDT op” DDT pp” DMD - (methoxychlor) Endosulfan alpha Endosulfan beta Endosulfan sulfate Endrin HCB HCH - alpha HCH - beta HCH - gamma (lindane) Cis – heptachlor epoxide Trans – heptachlor epoxide Heptachlor P B - 0 1/CHŻ wydanie 08 z dnia 25.07.2024 r.","search_zh":"有机氯农药含量 气相色谱-电子捕获检测法（GC-ECD） 狄氏剂 氧化氯丹 异狄氏剂 六氯苯（HCB） 七氯 P B - 0 1/CHŻ wydanie 08 z dnia 25.07.2024 r.","technique_zh":"气相色谱-电子捕获检测法（GC-ECD）","parameters_zh":[{"name":"Ryby: Aldryna","range":"(0,005-0,050) mg/kg"},{"name":"狄氏剂","range":"(0,005-0,050) mg/kg"},{"name":"Chlordan - cis (lambda)","range":"(0,005-0,050) mg/kg"},{"name":"Chlordan-trans (alfa)","range":"(0,005-0,050) mg/kg"},{"name":"氧化氯丹","range":"(0,005-0,050) mg/kg"},{"name":"pp”DDD","range":"(0,005-0,050) mg/kg"},{"name":"pp”DDE","range":"(0,005-0,050) mg/kg"},{"name":"pp”DDT","range":"(0,005-0,050) mg/kg"},{"name":"op” DDT","range":"(0,005-0,050) mg/kg"},{"name":"pp” DMD - (metoksychlor)","range":"(0,005-0,050) mg/kg"},{"name":"Endosulfan alfa","range":"(0,005-0,050) mg/kg"},{"name":"Endosulfan beta","range":"(0,005-0,050) mg/kg"},{"name":"Endosulfanu siarczan","range":"(0,005-0,050) mg/kg"},{"name":"异狄氏剂","range":"(0,005-0,050) mg/kg"},{"name":"六氯苯（HCB）","range":"(0,005-0,050) mg/kg"},{"name":"HCH - alfa","range":"(0,005-0,050) mg/kg"},{"name":"HCH - beta","range":"(0,005-0,050) mg/kg"},{"name":"HCH - gamma (lindan)","range":"(0,005-0,050) mg/kg"},{"name":"Cis – epoksyd heptachloru","range":"(0,005-0,050) mg/kg"},{"name":"Trans – epoksyd heptachloru","range":"(0,005-0,050) mg/kg"},{"name":"七氯","range":"(0,005-0,050) mg/kg"}],"methodology_zh":"有机氯农药含量"},{"_id":"6a5e78434cc76d93cba3ace9","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Ryby, Produkty rybne","test_object_en":"Fish, Fish products","methodology":"Zawartość histaminy Ryby surowe","methodology_en":"Histamine content Raw fish","parameters":[{"name":"Zakres","range":"(15-400) mg/kg"},{"name":"Ryba w zalewie"},{"name":"Zakres","range":"(15-600)mg/kg"},{"name":"Ryba wędzona"},{"name":"Zakres","range":"(15-400)mg/kg"}],"parameters_en":[{"name":"Range","range":"(15-400) mg/kg"},{"name":"Fish in brine"},{"name":"Range","range":"(15-600)mg/kg"},{"name":"Smoked fish"},{"name":"Range","range":"(15-400)mg/kg"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)"],"technique_en":"High-performance liquid chromatography with diode array detection (HPLC-DAD)","computed":[],"computed_en":[],"activity":"Zawartość histaminy Ryby surowe\nZakres:\nZakres (15-400) mg/kg\nRyba w zalewie\nZakres (15-600)mg/kg\nRyba wędzona\nZakres (15-400)mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)","reference":"PB-32/CHŻ Wydanie 04 z dnia 19.02.2024 r.","norm_bases":["PB-32/CHŻ Wydanie 04 z dnia 19.02.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ryby, Produkty rybne Zawartość histaminy Ryby surowe\nZakres:\nZakres (15-400) mg/kg\nRyba w zalewie\nZakres (15-600)mg/kg\nRyba wędzona\nZakres (15-400)mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD) PB-32/CHŻ Wydanie 04 z dnia 19.02.2024 r. Ryby, Produkty rybne Zawartosc histaminy Ryby surowe\nZakres:\nZakres (15-400) mg/kg\nRyba w zalewie\nZakres (15-600)mg/kg\nRyba wedzona\nZakres (15-400)mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcja matryca diodowa (HPLC-DAD) PB-32/CHZ Wydanie 04 z dnia 19.02.2024 r.","categories":["other"],"row_index":37,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Fish, Fish products Histamine content Raw fish High-performance liquid chromatography with diode array detection (HPLC-DAD) Range Fish in brine Range Smoked fish Range PB-32/CHŻ Wydanie 04 z dnia 19.02.2024 r.","parameters_zh":[{"name":"范围","range":"(15-400) mg/kg"},{"name":"Ryba w zalewie"},{"name":"范围","range":"(15-600)mg/kg"},{"name":"Ryba wędzona"},{"name":"范围","range":"(15-400)mg/kg"}],"search_zh":"鱼、鱼制品 高效液相色谱-二极管阵列检测法（HPLC-DAD） 范围 范围 范围 PB-32/CHŻ Wydanie 04 z dnia 19.02.2024 r.","technique_zh":"高效液相色谱-二极管阵列检测法（HPLC-DAD）","test_object_zh":"鱼、鱼制品"},{"_id":"6a5e78434cc76d93cba3acea","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Mleko","test_object_en":"Milk","methodology":"Zawartość makrocyklicznych","methodology_en":"Content of macrocyclic","parameters":[{"name":"laktonów"},{"name":"Abamektyna"},{"name":"Zakres","range":"(10-40) μg/kg"},{"name":"Doramektyna"},{"name":"Zakres","range":"(10-40) μg/kg"},{"name":"Eprinomektyna"},{"name":"Zakres","range":"(10-40) μg/kg"},{"name":"Iwermektyna"},{"name":"Zakres","range":"(10-40) μg/kg"},{"name":"Moksydektyna"},{"name":"Zakres","range":"(10-80) μg/kg"}],"parameters_en":[{"name":"lactones"},{"name":"Abamectin"},{"name":"Range","range":"(10-40) μg/kg"},{"name":"Doramectin"},{"name":"Range","range":"(10-40) μg/kg"},{"name":"Eprinomectin"},{"name":"Range","range":"(10-40) μg/kg"},{"name":"Ivermectin"},{"name":"Range","range":"(10-40) μg/kg"},{"name":"Moxidectin"},{"name":"Range","range":"(10-80) μg/kg"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD)","computed":[],"computed_en":[],"activity":"Zawartość makrocyklicznych\nZakres:\nlaktonów\nAbamektyna\nZakres (10-40) μg/kg\nDoramektyna\nZakres (10-40) μg/kg\nEprinomektyna\nZakres (10-40) μg/kg\nIwermektyna\nZakres (10-40) μg/kg\nMoksydektyna\nZakres (10-80) μg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"PB-48/CHŻ Wydanie 05 z dnia 24.01.2024 r.","norm_bases":["PB-48/CHŻ Wydanie 05 z dnia 24.01.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mleko Zawartość makrocyklicznych\nZakres:\nlaktonów\nAbamektyna\nZakres (10-40) μg/kg\nDoramektyna\nZakres (10-40) μg/kg\nEprinomektyna\nZakres (10-40) μg/kg\nIwermektyna\nZakres (10-40) μg/kg\nMoksydektyna\nZakres (10-80) μg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) PB-48/CHŻ Wydanie 05 z dnia 24.01.2024 r. Mleko Zawartosc makrocyklicznych\nZakres:\nlaktonow\nAbamektyna\nZakres (10-40) μg/kg\nDoramektyna\nZakres (10-40) μg/kg\nEprinomektyna\nZakres (10-40) μg/kg\nIwermektyna\nZakres (10-40) μg/kg\nMoksydektyna\nZakres (10-80) μg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) PB-48/CHZ Wydanie 05 z dnia 24.01.2024 r.","categories":["food"],"row_index":38,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Milk Content of macrocyclic High-performance liquid chromatography with fluorescence detection (HPLC-FLD) lactones Abamectin Range Doramectin Range Eprinomectin Range Ivermectin Range Moxidectin Range PB-48/CHŻ Wydanie 05 z dnia 24.01.2024 r.","parameters_zh":[{"name":"laktonów"},{"name":"Abamektyna"},{"name":"范围","range":"(10-40) μg/kg"},{"name":"多拉菌素"},{"name":"范围","range":"(10-40) μg/kg"},{"name":"乙酰氨基阿维菌素"},{"name":"范围","range":"(10-40) μg/kg"},{"name":"伊维菌素"},{"name":"范围","range":"(10-40) μg/kg"},{"name":"莫西菌素"},{"name":"范围","range":"(10-80) μg/kg"}],"search_zh":"乳 高效液相色谱-荧光检测法（HPLC-FLD） 范围 多拉菌素 范围 乙酰氨基阿维菌素 范围 伊维菌素 范围 莫西菌素 范围 PB-48/CHŻ Wydanie 05 z dnia 24.01.2024 r.","technique_zh":"高效液相色谱-荧光检测法（HPLC-FLD）","test_object_zh":"乳"},{"_id":"6a5e78434cc76d93cba3aceb","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Wątroba","test_object_en":"Liver","methodology":"Zawartość makrocyklicznych","methodology_en":"Content of macrocyclic","parameters":[{"name":"laktonów Wątroba – bydło, owca"},{"name":"Abamektyna"},{"name":"Zakres","range":"(10-40) μg/kg"},{"name":"Doramektyna"},{"name":"Zakres","range":"(10-200) μg/kg"},{"name":"Eprinomektyna"},{"name":"Zakres","range":"(200-2250) μg/kg"},{"name":"Iwermektyna"},{"name":"Zakres","range":"(10-200) μg/kg"},{"name":"Moksydektyna"},{"name":"Zakres","range":"(10-200) μg/kg"},{"name":"Wątroba – drób Abamektyna"},{"name":"Zakres","range":"(10-40) μg/kg"},{"name":"Doramektyna"},{"name":"Zakres","range":"(10-40) μg/kg"},{"name":"Eprinomektyna"},{"name":"Zakres","range":"(10-100) μg/kg"},{"name":"Iwermektyna"},{"name":"Zakres","range":"(10-40) μg/kg"},{"name":"Moksydektyna"},{"name":"Zakres","range":"(10-100) μg/kg"},{"name":"Wątroba – świnia Abamektyna"},{"name":"Zakres","range":"(10-40) μg/kg"},{"name":"Doramektyna"},{"name":"Zakres","range":"(10-200) μg/kg"},{"name":"Eprinomektyna"},{"name":"Zakres","range":"(10-100) μg/kg"},{"name":"Iwermektyna"},{"name":"Zakres","range":"(10-200) μg/kg"},{"name":"Moksydektyna"},{"name":"Zakres","range":"(10-100) μg/kg"}],"parameters_en":[{"name":"lactones Liver – cattle, sheep"},{"name":"Abamectin"},{"name":"Range","range":"(10-40) μg/kg"},{"name":"Doramectin"},{"name":"Range","range":"(10-200) μg/kg"},{"name":"Eprinomectin"},{"name":"Range","range":"(200-2250) μg/kg"},{"name":"Ivermectin"},{"name":"Range","range":"(10-200) μg/kg"},{"name":"Moxidectin"},{"name":"Range","range":"(10-200) μg/kg"},{"name":"Liver – poultry Abamectin"},{"name":"Range","range":"(10-40) μg/kg"},{"name":"Doramectin"},{"name":"Range","range":"(10-40) μg/kg"},{"name":"Eprinomectin"},{"name":"Range","range":"(10-100) μg/kg"},{"name":"Ivermectin"},{"name":"Range","range":"(10-40) μg/kg"},{"name":"Moxidectin"},{"name":"Range","range":"(10-100) μg/kg"},{"name":"Liver – pig Abamectin"},{"name":"Range","range":"(10-40) μg/kg"},{"name":"Doramectin"},{"name":"Range","range":"(10-200) μg/kg"},{"name":"Eprinomectin"},{"name":"Range","range":"(10-100) μg/kg"},{"name":"Ivermectin"},{"name":"Range","range":"(10-200) μg/kg"},{"name":"Moxidectin"},{"name":"Range","range":"(10-100) μg/kg"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD)","computed":[],"computed_en":[],"activity":"Zawartość makrocyklicznych\nZakres:\nlaktonów Wątroba – bydło, owca\nAbamektyna\nZakres (10-40) μg/kg\nDoramektyna\nZakres (10-200) μg/kg\nEprinomektyna\nZakres (200-2250) μg/kg\nIwermektyna\nZakres (10-200) μg/kg\nMoksydektyna\nZakres (10-200) μg/kg\nWątroba – drób Abamektyna\nZakres (10-40) μg/kg\nDoramektyna\nZakres (10-40) μg/kg\nEprinomektyna\nZakres (10-100) μg/kg\nIwermektyna\nZakres (10-40) μg/kg\nMoksydektyna\nZakres (10-100) μg/kg\nWątroba – świnia Abamektyna\nZakres (10-40) μg/kg\nDoramektyna\nZakres (10-200) μg/kg\nEprinomektyna\nZakres (10-100) μg/kg\nIwermektyna\nZakres (10-200) μg/kg\nMoksydektyna\nZakres (10-100) μg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"PB-48/CHŻ Wydanie 05 z dnia 24.01.2024 r.","norm_bases":["PB-48/CHŻ Wydanie 05 z dnia 24.01.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wątroba Zawartość makrocyklicznych\nZakres:\nlaktonów Wątroba – bydło, owca\nAbamektyna\nZakres (10-40) μg/kg\nDoramektyna\nZakres (10-200) μg/kg\nEprinomektyna\nZakres (200-2250) μg/kg\nIwermektyna\nZakres (10-200) μg/kg\nMoksydektyna\nZakres (10-200) μg/kg\nWątroba – drób Abamektyna\nZakres (10-40) μg/kg\nDoramektyna\nZakres (10-40) μg/kg\nEprinomektyna\nZakres (10-100) μg/kg\nIwermektyna\nZakres (10-40) μg/kg\nMoksydektyna\nZakres (10-100) μg/kg\nWątroba – świnia Abamektyna\nZakres (10-40) μg/kg\nDoramektyna\nZakres (10-200) μg/kg\nEprinomektyna\nZakres (10-100) μg/kg\nIwermektyna\nZakres (10-200) μg/kg\nMoksydektyna\nZakres (10-100) μg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) PB-48/CHŻ Wydanie 05 z dnia 24.01.2024 r. Watroba Zawartosc makrocyklicznych\nZakres:\nlaktonow Watroba – bydlo, owca\nAbamektyna\nZakres (10-40) μg/kg\nDoramektyna\nZakres (10-200) μg/kg\nEprinomektyna\nZakres (200-2250) μg/kg\nIwermektyna\nZakres (10-200) μg/kg\nMoksydektyna\nZakres (10-200) μg/kg\nWatroba – drob Abamektyna\nZakres (10-40) μg/kg\nDoramektyna\nZakres (10-40) μg/kg\nEprinomektyna\nZakres (10-100) μg/kg\nIwermektyna\nZakres (10-40) μg/kg\nMoksydektyna\nZakres (10-100) μg/kg\nWatroba – swinia Abamektyna\nZakres (10-40) μg/kg\nDoramektyna\nZakres (10-200) μg/kg\nEprinomektyna\nZakres (10-100) μg/kg\nIwermektyna\nZakres (10-200) μg/kg\nMoksydektyna\nZakres (10-100) μg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) PB-48/CHZ Wydanie 05 z dnia 24.01.2024 r.","categories":["other"],"row_index":39,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Liver Content of macrocyclic High-performance liquid chromatography with fluorescence detection (HPLC-FLD) lactones Liver – cattle, sheep Abamectin Range Doramectin Range Eprinomectin Range Ivermectin Range Moxidectin Range Liver – poultry Abamectin Range Doramectin Range Eprinomectin Range Ivermectin Range Moxidectin Range Liver – pig Abamectin Range Doramectin Range Eprinomectin Range Ivermectin Range Moxidectin Range PB-48/CHŻ Wydanie 05 z dnia 24.01.2024 r.","parameters_zh":[{"name":"laktonów Wątroba – bydło, owca"},{"name":"Abamektyna"},{"name":"范围","range":"(10-40) μg/kg"},{"name":"多拉菌素"},{"name":"范围","range":"(10-200) μg/kg"},{"name":"乙酰氨基阿维菌素"},{"name":"范围","range":"(200-2250) μg/kg"},{"name":"伊维菌素"},{"name":"范围","range":"(10-200) μg/kg"},{"name":"莫西菌素"},{"name":"范围","range":"(10-200) μg/kg"},{"name":"Wątroba – drób Abamektyna"},{"name":"范围","range":"(10-40) μg/kg"},{"name":"多拉菌素"},{"name":"范围","range":"(10-40) μg/kg"},{"name":"乙酰氨基阿维菌素"},{"name":"范围","range":"(10-100) μg/kg"},{"name":"伊维菌素"},{"name":"范围","range":"(10-40) μg/kg"},{"name":"莫西菌素"},{"name":"范围","range":"(10-100) μg/kg"},{"name":"Wątroba – świnia Abamektyna"},{"name":"范围","range":"(10-40) μg/kg"},{"name":"多拉菌素"},{"name":"范围","range":"(10-200) μg/kg"},{"name":"乙酰氨基阿维菌素"},{"name":"范围","range":"(10-100) μg/kg"},{"name":"伊维菌素"},{"name":"范围","range":"(10-200) μg/kg"},{"name":"莫西菌素"},{"name":"范围","range":"(10-100) μg/kg"}],"search_zh":"高效液相色谱-荧光检测法（HPLC-FLD） 范围 多拉菌素 范围 乙酰氨基阿维菌素 范围 伊维菌素 范围 莫西菌素 范围 范围 多拉菌素 范围 乙酰氨基阿维菌素 范围 伊维菌素 范围 莫西菌素 范围 范围 多拉菌素 范围 乙酰氨基阿维菌素 范围 伊维菌素 范围 莫西菌素 范围 PB-48/CHŻ Wydanie 05 z dnia 24.01.2024 r.","technique_zh":"高效液相色谱-荧光检测法（HPLC-FLD）"},{"_id":"6a5e78434cc76d93cba3acec","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Surowica","test_object_en":"Serum","methodology":"Zawartość pozostałości hormonów naturalnych 17 beta – Estradiol (17 β – Estradiol)","methodology_en":"Content of natural hormone residues 17 beta – Estradiol (17 β – Estradiol)","parameters":[{"name":"Zakres","range":"(0,05 – 0,15) μg/kg"},{"name":"17 beta – Testosteron","range":"(17 β – Testosteron)"},{"name":"Zakres","range":"(0,3 – 35,0) μg/kg"}],"parameters_en":[{"name":"Range","range":"(0,05 – 0,15) μg/kg"},{"name":"17 beta – Testosterone","range":"(17 β – Testosteron)"},{"name":"Range","range":"(0,3 – 35,0) μg/kg"}],"technique":"Metoda chromatografii cieczowej sprzężonej z detekcją tandemową spektrometrią mas (LC-MS/MS)","techniques":["Metoda chromatografii cieczowej sprzężonej z detekcją tandemową spektrometrią mas (LC-MS/MS)"],"technique_en":"Liquid chromatography coupled with tandem mass spectrometry detection (LC-MS/MS)","computed":[],"computed_en":[],"activity":"Zawartość pozostałości hormonów naturalnych 17 beta – Estradiol (17 β – Estradiol)\nZakres:\nZakres (0,05 – 0,15) μg/kg\n17 beta – Testosteron (17 β – Testosteron)\nZakres (0,3 – 35,0) μg/kg\nMetoda chromatografii cieczowej sprzężonej z detekcją tandemową spektrometrią mas (LC-MS/MS)","reference":"PB-66/CHŻ Wydanie 02 z dnia 24.01.2024 r.","norm_bases":["PB-66/CHŻ Wydanie 02 z dnia 24.01.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Surowica Zawartość pozostałości hormonów naturalnych 17 beta – Estradiol (17 β – Estradiol)\nZakres:\nZakres (0,05 – 0,15) μg/kg\n17 beta – Testosteron (17 β – Testosteron)\nZakres (0,3 – 35,0) μg/kg\nMetoda chromatografii cieczowej sprzężonej z detekcją tandemową spektrometrią mas (LC-MS/MS) PB-66/CHŻ Wydanie 02 z dnia 24.01.2024 r. Surowica Zawartosc pozostalosci hormonow naturalnych 17 beta – Estradiol (17 β – Estradiol)\nZakres:\nZakres (0,05 – 0,15) μg/kg\n17 beta – Testosteron (17 β – Testosteron)\nZakres (0,3 – 35,0) μg/kg\nMetoda chromatografii cieczowej sprzezonej z detekcja tandemowa spektrometria mas (LC-MS/MS) PB-66/CHZ Wydanie 02 z dnia 24.01.2024 r.","categories":["other"],"row_index":40,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Serum Content of natural hormone residues 17 beta – Estradiol (17 β – Estradiol) Liquid chromatography coupled with tandem mass spectrometry detection (LC-MS/MS) Range 17 beta – Testosterone Range PB-66/CHŻ Wydanie 02 z dnia 24.01.2024 r.","parameters_zh":[{"name":"范围","range":"(0,05 – 0,15) μg/kg"},{"name":"17 beta – Testosteron","range":"(17 β – Testosteron)"},{"name":"范围","range":"(0,3 – 35,0) μg/kg"}],"search_zh":"血清 液相色谱-串联质谱联用检测法（LC-MS/MS） 范围 范围 PB-66/CHŻ Wydanie 02 z dnia 24.01.2024 r.","test_object_zh":"血清","technique_zh":"液相色谱-串联质谱联用检测法（LC-MS/MS）"},{"_id":"6a5e78434cc76d93cba3aced","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Mięśnie zwierząt rzeźnych i ryb, Mocz, Mleko, Jaja, Surowica","test_object_en":"Muscle of slaughter animals and fish, Urine, Milk, Eggs, Serum","methodology":"Zawartość metabolitów nitrofuranów 2) 3)","methodology_en":"Nitrofuran metabolite content 2) 3)","parameters":[],"parameters_en":[],"technique":"Metoda chromatografii cieczowej sprzężonej z detekcją tandemową spektrometrią mas (LC-MS/MS)","techniques":["Metoda chromatografii cieczowej sprzężonej z detekcją tandemową spektrometrią mas (LC-MS/MS)"],"technique_en":"Liquid chromatography coupled with tandem mass spectrometry detection (LC-MS/MS)","computed":[],"computed_en":[],"activity":"Zawartość metabolitów nitrofuranów 2) 3)\nMetoda chromatografii cieczowej sprzężonej z detekcją tandemową spektrometrią mas (LC-MS/MS)","reference":"PB-38/CHŻ 4)","norm_bases":["PB-38/CHŻ 4)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mięśnie zwierząt rzeźnych i ryb, Mocz, Mleko, Jaja, Surowica Zawartość metabolitów nitrofuranów 2) 3)\nMetoda chromatografii cieczowej sprzężonej z detekcją tandemową spektrometrią mas (LC-MS/MS) PB-38/CHŻ 4) Miesnie zwierzat rzeznych i ryb, Mocz, Mleko, Jaja, Surowica Zawartosc metabolitow nitrofuranow 2) 3)\nMetoda chromatografii cieczowej sprzezonej z detekcja tandemowa spektrometria mas (LC-MS/MS) PB-38/CHZ 4)","categories":["food"],"row_index":41,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Muscle of slaughter animals and fish, Urine, Milk, Eggs, Serum Nitrofuran metabolite content 2) 3) Liquid chromatography coupled with tandem mass spectrometry detection (LC-MS/MS) PB-38/CHŻ 4)","search_zh":"液相色谱-串联质谱联用检测法（LC-MS/MS） PB-38/CHŻ 4)","technique_zh":"液相色谱-串联质谱联用检测法（LC-MS/MS）"},{"_id":"6a5e78434cc76d93cba3acee","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Mięśnie zwierząt rzeźnych i ryb, Mocz, Mleko, Jaja, Woda","test_object_en":"Muscle of slaughter animals and fish, Urine, Milk, Eggs, Water","methodology":"Zawartość chloramfenikolu (CAP) 2) 3)","methodology_en":"Chloramphenicol (CAP) content 2) 3)","parameters":[],"parameters_en":[],"technique":"Metoda chromatografii cieczowej sprzężonej z detekcją tandemową spektrometrią mas (LC-MS/MS)","techniques":["Metoda chromatografii cieczowej sprzężonej z detekcją tandemową spektrometrią mas (LC-MS/MS)"],"technique_en":"Liquid chromatography coupled with tandem mass spectrometry detection (LC-MS/MS)","computed":[],"computed_en":[],"activity":"Zawartość chloramfenikolu (CAP) 2) 3)\nMetoda chromatografii cieczowej sprzężonej z detekcją tandemową spektrometrią mas (LC-MS/MS)","reference":"PB-22/CHŻ 4)","norm_bases":["PB-22/CHŻ 4)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mięśnie zwierząt rzeźnych i ryb, Mocz, Mleko, Jaja, Woda Zawartość chloramfenikolu (CAP) 2) 3)\nMetoda chromatografii cieczowej sprzężonej z detekcją tandemową spektrometrią mas (LC-MS/MS) PB-22/CHŻ 4) Miesnie zwierzat rzeznych i ryb, Mocz, Mleko, Jaja, Woda Zawartosc chloramfenikolu (CAP) 2) 3)\nMetoda chromatografii cieczowej sprzezonej z detekcja tandemowa spektrometria mas (LC-MS/MS) PB-22/CHZ 4)","categories":["food","water"],"row_index":42,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Muscle of slaughter animals and fish, Urine, Milk, Eggs, Water Chloramphenicol (CAP) content 2) 3) Liquid chromatography coupled with tandem mass spectrometry detection (LC-MS/MS) PB-22/CHŻ 4)","search_zh":"液相色谱-串联质谱联用检测法（LC-MS/MS） PB-22/CHŻ 4)","technique_zh":"液相色谱-串联质谱联用检测法（LC-MS/MS）"},{"_id":"6a5e78434cc76d93cba3acef","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Mięśnie zwierząt rzeźnych i ryb, Mocz, Woda","test_object_en":"Muscle of slaughter animals and fish, Urine, Water","methodology":"Zawartość hormonów anabolicznych 2) 3)","methodology_en":"Anabolic hormone content 2) 3)","parameters":[],"parameters_en":[],"technique":"Metoda chromatografii cieczowej sprzężonej z detekcją tandemową spektrometrią mas (LC-MS/MS)","techniques":["Metoda chromatografii cieczowej sprzężonej z detekcją tandemową spektrometrią mas (LC-MS/MS)"],"technique_en":"Liquid chromatography coupled with tandem mass spectrometry detection (LC-MS/MS)","computed":[],"computed_en":[],"activity":"Zawartość hormonów anabolicznych 2) 3)\nMetoda chromatografii cieczowej sprzężonej z detekcją tandemową spektrometrią mas (LC-MS/MS)","reference":"PB-44/CHŻ 4)","norm_bases":["PB-44/CHŻ 4)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mięśnie zwierząt rzeźnych i ryb, Mocz, Woda Zawartość hormonów anabolicznych 2) 3)\nMetoda chromatografii cieczowej sprzężonej z detekcją tandemową spektrometrią mas (LC-MS/MS) PB-44/CHŻ 4) Miesnie zwierzat rzeznych i ryb, Mocz, Woda Zawartosc hormonow anabolicznych 2) 3)\nMetoda chromatografii cieczowej sprzezonej z detekcja tandemowa spektrometria mas (LC-MS/MS) PB-44/CHZ 4)","categories":["water"],"row_index":43,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Muscle of slaughter animals and fish, Urine, Water Anabolic hormone content 2) 3) Liquid chromatography coupled with tandem mass spectrometry detection (LC-MS/MS) PB-44/CHŻ 4)","search_zh":"液相色谱-串联质谱联用检测法（LC-MS/MS） PB-44/CHŻ 4)","technique_zh":"液相色谱-串联质谱联用检测法（LC-MS/MS）"},{"_id":"6a5e78434cc76d93cba3acf0","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Ryby","test_object_en":"Fish","methodology":"Zawartość barwników 2) 3)","methodology_en":"Dye content 2) 3)","parameters":[],"parameters_en":[],"technique":"Metoda chromatografii cieczowej sprzężonej z detekcją tandemową spektrometrią mas (LC-MS/MS)","techniques":["Metoda chromatografii cieczowej sprzężonej z detekcją tandemową spektrometrią mas (LC-MS/MS)"],"technique_en":"Liquid chromatography coupled with tandem mass spectrometry detection (LC-MS/MS)","computed":[],"computed_en":[],"activity":"Zawartość barwników 2) 3)\nMetoda chromatografii cieczowej sprzężonej z detekcją tandemową spektrometrią mas (LC-MS/MS)","reference":"PB-20 /CHŻ 4)","norm_bases":["PB-20 /CHŻ 4)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ryby Zawartość barwników 2) 3)\nMetoda chromatografii cieczowej sprzężonej z detekcją tandemową spektrometrią mas (LC-MS/MS) PB-20 /CHŻ 4) Ryby Zawartosc barwnikow 2) 3)\nMetoda chromatografii cieczowej sprzezonej z detekcja tandemowa spektrometria mas (LC-MS/MS) PB-20 /CHZ 4)","categories":["other"],"row_index":44,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Fish Dye content 2) 3) Liquid chromatography coupled with tandem mass spectrometry detection (LC-MS/MS) PB-20 /CHŻ 4)","search_zh":"鱼 液相色谱-串联质谱联用检测法（LC-MS/MS） PB-20 /CHŻ 4)","technique_zh":"液相色谱-串联质谱联用检测法（LC-MS/MS）","test_object_zh":"鱼"},{"_id":"6a5e78434cc76d93cba3acf1","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Mocz, Woda","test_object_en":"Urine, Water","methodology":"Zawartość tyreostatyków 2) 3)","methodology_en":"Content of thyreostats 2) 3)","parameters":[],"parameters_en":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS/MS)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS/MS)"],"technique_en":"High-performance liquid chromatography with tandem mass spectrometry detection (LC-MS/MS)","computed":[],"computed_en":[],"activity":"Zawartość tyreostatyków 2) 3)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS/MS)","reference":"PB-30/CHŻ 4)","norm_bases":["PB-30/CHŻ 4)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mocz, Woda Zawartość tyreostatyków 2) 3)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS/MS) PB-30/CHŻ 4) Mocz, Woda Zawartosc tyreostatykow 2) 3)\nMetoda wysokosprawnej chromatografii cieczowej z detekcja tandemowa spektrometria mas (LC-MS/MS) PB-30/CHZ 4)","categories":["water"],"row_index":45,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Urine, Water Content of thyreostats 2) 3) High-performance liquid chromatography with tandem mass spectrometry detection (LC-MS/MS) PB-30/CHŻ 4)","search_zh":"高效液相色谱-串联质谱法（LC-MS/MS） PB-30/CHŻ 4)","technique_zh":"高效液相色谱-串联质谱法（LC-MS/MS）"},{"_id":"6a5e78434cc76d93cba3acf2","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Wątroba","test_object_en":"Liver","methodology":"Zawartość kokcydiostatyków 2) 3)","methodology_en":"Coccidiostat content 2) 3)","parameters":[],"parameters_en":[],"technique":"Metoda chromatografii cieczowej sprzężonej z detekcją tandemową spektrometrią mas (LC-MS/MS)","techniques":["Metoda chromatografii cieczowej sprzężonej z detekcją tandemową spektrometrią mas (LC-MS/MS)"],"technique_en":"Liquid chromatography coupled with tandem mass spectrometry detection (LC-MS/MS)","computed":[],"computed_en":[],"activity":"Zawartość kokcydiostatyków 2) 3)\nMetoda chromatografii cieczowej sprzężonej z detekcją tandemową spektrometrią mas (LC-MS/MS)","reference":"PB-36/CHŻ 4)","norm_bases":["PB-36/CHŻ 4)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wątroba Zawartość kokcydiostatyków 2) 3)\nMetoda chromatografii cieczowej sprzężonej z detekcją tandemową spektrometrią mas (LC-MS/MS) PB-36/CHŻ 4) Watroba Zawartosc kokcydiostatykow 2) 3)\nMetoda chromatografii cieczowej sprzezonej z detekcja tandemowa spektrometria mas (LC-MS/MS) PB-36/CHZ 4)","categories":["other"],"row_index":46,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Liver Coccidiostat content 2) 3) Liquid chromatography coupled with tandem mass spectrometry detection (LC-MS/MS) PB-36/CHŻ 4)","search_zh":"液相色谱-串联质谱联用检测法（LC-MS/MS） PB-36/CHŻ 4)","technique_zh":"液相色谱-串联质谱联用检测法（LC-MS/MS）"},{"_id":"6a5e78434cc76d93cba3acf3","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Mięśnie zwierząt rzeźnych","test_object_en":"Muscle of slaughter animals","methodology":"Zawartość leków przeciwbakteryjnych 2) 3)","methodology_en":"Antibacterial drug content 2) 3)","parameters":[],"parameters_en":[],"technique":"Metoda chromatografii cieczowej sprzężonej z detekcją tandemową spektrometrią mas (LC-MS/MS)","techniques":["Metoda chromatografii cieczowej sprzężonej z detekcją tandemową spektrometrią mas (LC-MS/MS)"],"technique_en":"Liquid chromatography coupled with tandem mass spectrometry detection (LC-MS/MS)","computed":[],"computed_en":[],"activity":"Zawartość leków przeciwbakteryjnych 2) 3)\nMetoda chromatografii cieczowej sprzężonej z detekcją tandemową spektrometrią mas (LC-MS/MS)","reference":"PB-58/CHŻ 4)","norm_bases":["PB-58/CHŻ 4)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mięśnie zwierząt rzeźnych Zawartość leków przeciwbakteryjnych 2) 3)\nMetoda chromatografii cieczowej sprzężonej z detekcją tandemową spektrometrią mas (LC-MS/MS) PB-58/CHŻ 4) Miesnie zwierzat rzeznych Zawartosc lekow przeciwbakteryjnych 2) 3)\nMetoda chromatografii cieczowej sprzezonej z detekcja tandemowa spektrometria mas (LC-MS/MS) PB-58/CHZ 4)","categories":["pharma"],"row_index":47,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Muscle of slaughter animals Antibacterial drug content 2) 3) Liquid chromatography coupled with tandem mass spectrometry detection (LC-MS/MS) PB-58/CHŻ 4)","search_zh":"液相色谱-串联质谱联用检测法（LC-MS/MS） PB-58/CHŻ 4)","technique_zh":"液相色谱-串联质谱联用检测法（LC-MS/MS）"},{"_id":"6a5e78434cc76d93cba3acf4","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Żywność 1)","test_object_en":"Food 1)","methodology":"Zawartość leków przeciwbakteryjnych 2) 3)","methodology_en":"Antibacterial drug content 2) 3)","parameters":[],"parameters_en":[],"technique":"Metoda chromatografii cieczowej sprzężonej z detekcją tandemową spektrometrią mas (LC-MS/MS)","techniques":["Metoda chromatografii cieczowej sprzężonej z detekcją tandemową spektrometrią mas (LC-MS/MS)"],"technique_en":"Liquid chromatography coupled with tandem mass spectrometry detection (LC-MS/MS)","computed":[],"computed_en":[],"activity":"Zawartość leków przeciwbakteryjnych 2) 3)\nMetoda chromatografii cieczowej sprzężonej z detekcją tandemową spektrometrią mas (LC-MS/MS)","reference":"PB-58/CHŻ 4)","norm_bases":["PB-58/CHŻ 4)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Żywność 1) Zawartość leków przeciwbakteryjnych 2) 3)\nMetoda chromatografii cieczowej sprzężonej z detekcją tandemową spektrometrią mas (LC-MS/MS) PB-58/CHŻ 4) Zywnosc 1) Zawartosc lekow przeciwbakteryjnych 2) 3)\nMetoda chromatografii cieczowej sprzezonej z detekcja tandemowa spektrometria mas (LC-MS/MS) PB-58/CHZ 4)","categories":["food","pharma"],"row_index":48,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Food 1) Antibacterial drug content 2) 3) Liquid chromatography coupled with tandem mass spectrometry detection (LC-MS/MS) PB-58/CHŻ 4)","search_zh":"食品 1) 液相色谱-串联质谱联用检测法（LC-MS/MS） PB-58/CHŻ 4)","test_object_zh":"食品 1)","technique_zh":"液相色谱-串联质谱联用检测法（LC-MS/MS）"},{"_id":"6a5e78434cc76d93cba3acf5","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Mocz zwierząt rzeźnych","test_object_en":"Urine of slaughter animals","methodology":"Zawartość i stanozololu i 16β- hydroksystanozololu 3)","methodology_en":"Content of stanozolol and 16β- hydroxystanozolol 3)","parameters":[],"parameters_en":[],"technique":"Metoda chromatografii cieczowej sprzężonej z detekcją tandemową spektrometrią mas (LC-MS/MS)","techniques":["Metoda chromatografii cieczowej sprzężonej z detekcją tandemową spektrometrią mas (LC-MS/MS)"],"technique_en":"Liquid chromatography coupled with tandem mass spectrometry detection (LC-MS/MS)","computed":[],"computed_en":[],"activity":"Zawartość i stanozololu i 16β- hydroksystanozololu 3)\nMetoda chromatografii cieczowej sprzężonej z detekcją tandemową spektrometrią mas (LC-MS/MS)","reference":"PB-64/CHŻ 4)","norm_bases":["PB-64/CHŻ 4)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mocz zwierząt rzeźnych Zawartość i stanozololu i 16β- hydroksystanozololu 3)\nMetoda chromatografii cieczowej sprzężonej z detekcją tandemową spektrometrią mas (LC-MS/MS) PB-64/CHŻ 4) Mocz zwierzat rzeznych Zawartosc i stanozololu i 16β- hydroksystanozololu 3)\nMetoda chromatografii cieczowej sprzezonej z detekcja tandemowa spektrometria mas (LC-MS/MS) PB-64/CHZ 4)","categories":["other"],"row_index":49,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Urine of slaughter animals Content of stanozolol and 16β- hydroxystanozolol 3) Liquid chromatography coupled with tandem mass spectrometry detection (LC-MS/MS) PB-64/CHŻ 4)","search_zh":"液相色谱-串联质谱联用检测法（LC-MS/MS） PB-64/CHŻ 4)","technique_zh":"液相色谱-串联质谱联用检测法（LC-MS/MS）"},{"_id":"6a5e78434cc76d93cba3acf6","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Tłuszcz zwierząt rzeźnych","test_object_en":"Fat of slaughter animals","methodology":"Zawartość gestagenów 2) 3)","methodology_en":"Gestagen content 2) 3)","parameters":[],"parameters_en":[],"technique":"Metoda chromatografii cieczowej sprzężonej z detekcją tandemową spektrometrią mas (LC-MS/MS)","techniques":["Metoda chromatografii cieczowej sprzężonej z detekcją tandemową spektrometrią mas (LC-MS/MS)"],"technique_en":"Liquid chromatography coupled with tandem mass spectrometry detection (LC-MS/MS)","computed":[],"computed_en":[],"activity":"Zawartość gestagenów 2) 3)\nMetoda chromatografii cieczowej sprzężonej z detekcją tandemową spektrometrią mas (LC-MS/MS)","reference":"PB-63/CHŻ 4)","norm_bases":["PB-63/CHŻ 4)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Tłuszcz zwierząt rzeźnych Zawartość gestagenów 2) 3)\nMetoda chromatografii cieczowej sprzężonej z detekcją tandemową spektrometrią mas (LC-MS/MS) PB-63/CHŻ 4) Tluszcz zwierzat rzeznych Zawartosc gestagenow 2) 3)\nMetoda chromatografii cieczowej sprzezonej z detekcja tandemowa spektrometria mas (LC-MS/MS) PB-63/CHZ 4)","categories":["other"],"row_index":50,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Fat of slaughter animals Gestagen content 2) 3) Liquid chromatography coupled with tandem mass spectrometry detection (LC-MS/MS) PB-63/CHŻ 4)","search_zh":"液相色谱-串联质谱联用检测法（LC-MS/MS） PB-63/CHŻ 4)","technique_zh":"液相色谱-串联质谱联用检测法（LC-MS/MS）"},{"_id":"6a5e78434cc76d93cba3acf7","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Próbki pobrane na etapie produkcji pierwotnej, w tym materiał biologiczny: odchody zwierzęce, kurz, wymazy, narządy wewnętrzne zwierząt","test_object_en":"Samples taken at the primary production stage, including biological material: animal droppings, dust, swabs, internal organs of animals","methodology":"Obecność i identyfikacja Salmonella spp.","methodology_en":"Presence and identification of Salmonella spp.","parameters":[],"parameters_en":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"technique_en":"Culture method with biochemical and serological confirmation","computed":[],"computed_en":[],"activity":"Obecność i identyfikacja Salmonella spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PN-EN ISO 6579-1:2017-04 +A1:2020-09 z wyłączeniem Załącznika D Schemat White‘a – Kauffmanna – Le Minora: 2007 ISO/TR 6579-3:2014","norm_bases":["PN-EN ISO 6579-1:2017-04 +A1:2020-09 z wyłączeniem Załącznika D Schemat White‘a – Kauffmanna – Le Minora: 2007 ISO/TR 6579-3:2014"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Próbki pobrane na etapie produkcji pierwotnej, w tym materiał biologiczny: odchody zwierzęce, kurz, wymazy, narządy wewnętrzne zwierząt Obecność i identyfikacja Salmonella spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579-1:2017-04 +A1:2020-09 z wyłączeniem Załącznika D Schemat White‘a – Kauffmanna – Le Minora: 2007 ISO/TR 6579-3:2014 Probki pobrane na etapie produkcji pierwotnej, w tym material biologiczny: odchody zwierzece, kurz, wymazy, narzady wewnetrzne zwierzat Obecnosc i identyfikacja Salmonella spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579-1:2017-04 +A1:2020-09 z wylaczeniem Zalacznika D Schemat White‘a – Kauffmanna – Le Minora: 2007 ISO/TR 6579-3:2014","categories":["microbiology","materials"],"row_index":51,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Samples taken at the primary production stage, including biological material: animal droppings, dust, swabs, internal organs of animals Presence and identification of Salmonella spp. Culture method with biochemical and serological confirmation PN-EN ISO 6579-1:2017-04 +A1:2020-09 z wyłączeniem Załącznika D Schemat White‘a – Kauffmanna – Le Minora: 2007 ISO/TR 6579-3:2014","search_zh":"沙门氏菌属的检出与鉴定 培养法结合生化与血清学确认 PN-EN ISO 6579-1:2017-04 +A1:2020-09 z wyłączeniem Załącznika D Schemat White‘a – Kauffmanna – Le Minora: 2007 ISO/TR 6579-3:2014","technique_zh":"培养法结合生化与血清学确认","methodology_zh":"沙门氏菌属的检出与鉴定"},{"_id":"6a5e78434cc76d93cba3acf8","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Mózgowie zwierząt","test_object_en":"Animal brain tissue","methodology":"Obecność antygenu lyssawirusa","methodology_en":"Presence of lyssavirus antigen","parameters":[],"parameters_en":[],"technique":"Metoda immunofluorescencji bezpośredniej","techniques":["Metoda immunofluorescencji bezpośredniej"],"technique_en":"Direct immunofluorescence method","computed":[],"computed_en":[],"activity":"Obecność antygenu lyssawirusa\nMetoda immunofluorescencji bezpośredniej","reference":"Instrukcja Głównego Lekarza Weterynarii Nr GIWpr-02010-3/2018 z dnia 7 lutego 2018 r.","norm_bases":["Instrukcja Głównego Lekarza Weterynarii Nr GIWpr-02010-3/2018 z dnia 7 lutego 2018 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mózgowie zwierząt Obecność antygenu lyssawirusa\nMetoda immunofluorescencji bezpośredniej Instrukcja Głównego Lekarza Weterynarii Nr GIWpr-02010-3/2018 z dnia 7 lutego 2018 r. Mozgowie zwierzat Obecnosc antygenu lyssawirusa\nMetoda immunofluorescencji bezposredniej Instrukcja Glownego Lekarza Weterynarii Nr GIWpr-02010-3/2018 z dnia 7 lutego 2018 r.","categories":["other"],"row_index":52,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Animal brain tissue Presence of lyssavirus antigen Direct immunofluorescence method Instrukcja Głównego Lekarza Weterynarii Nr GIWpr-02010-3/2018 z dnia 7 lutego 2018 r.","methodology_zh":"狂犬病病毒抗原的检出","search_zh":"动物脑组织 狂犬病病毒抗原的检出 直接免疫荧光法 Instrukcja Głównego Lekarza Weterynarii Nr GIWpr-02010-3/2018 z dnia 7 lutego 2018 r.","test_object_zh":"动物脑组织","technique_zh":"直接免疫荧光法"},{"_id":"6a5e78434cc76d93cba3acf9","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Surowica krwi bydła, owiec i kóz","test_object_en":"Blood serum of cattle, sheep and goats","methodology":"Obecność przeciwciał przeciwko Brucella spp.","methodology_en":"Presence of antibodies against Brucella spp.","parameters":[],"parameters_en":[],"technique":"Metoda odczynu kwaśnej aglutynacji płytowej (OKAP)","techniques":["Metoda odczynu kwaśnej aglutynacji płytowej (OKAP)"],"technique_en":"Acidified plate agglutination test (OKAP)","computed":[],"computed_en":[],"activity":"Obecność przeciwciał przeciwko Brucella spp.\nMetoda odczynu kwaśnej aglutynacji płytowej (OKAP)","reference":"Instrukcja Nr 27/2003 Głównego Lekarza Weterynarii z dnia 25 czerwca 2003 r. Nr GIW VII.420/lab – 4/2003","norm_bases":["Instrukcja Nr 27/2003 Głównego Lekarza Weterynarii z dnia 25 czerwca 2003 r. Nr GIW VII.420/lab – 4/2003"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Surowica krwi bydła, owiec i kóz Obecność przeciwciał przeciwko Brucella spp.\nMetoda odczynu kwaśnej aglutynacji płytowej (OKAP) Instrukcja Nr 27/2003 Głównego Lekarza Weterynarii z dnia 25 czerwca 2003 r. Nr GIW VII.420/lab – 4/2003 Surowica krwi bydla, owiec i koz Obecnosc przeciwcial przeciwko Brucella spp.\nMetoda odczynu kwasnej aglutynacji plytowej (OKAP) Instrukcja Nr 27/2003 Glownego Lekarza Weterynarii z dnia 25 czerwca 2003 r. Nr GIW VII.420/lab – 4/2003","categories":["other"],"row_index":53,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Blood serum of cattle, sheep and goats Presence of antibodies against Brucella spp. Acidified plate agglutination test (OKAP) Instrukcja Nr 27/2003 Głównego Lekarza Weterynarii z dnia 25 czerwca 2003 r. Nr GIW VII.420/lab – 4/2003","search_zh":"布鲁氏菌属（Brucella spp.）抗体的检出 酸性平板凝集试验法（OKAP） Instrukcja Nr 27/2003 Głównego Lekarza Weterynarii z dnia 25 czerwca 2003 r. Nr GIW VII.420/lab – 4/2003","technique_zh":"酸性平板凝集试验法（OKAP）","methodology_zh":"布鲁氏菌属（Brucella spp.）抗体的检出"},{"_id":"6a5e78434cc76d93cba3acfa","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Surowica krwi bydła","test_object_en":"Cattle blood serum","methodology":"Obecność przeciwciał przeciwko Brucella spp.","methodology_en":"Presence of antibodies against Brucella spp.","parameters":[],"parameters_en":[],"technique":"Metoda odczynu aglutynacji probówkowej (OA)","techniques":["Metoda odczynu aglutynacji probówkowej (OA)"],"technique_en":"Tube agglutination test (OA)","computed":[],"computed_en":[],"activity":"Obecność przeciwciał przeciwko Brucella spp.\nMetoda odczynu aglutynacji probówkowej (OA)","reference":"Instrukcja Nr 26/2003 Głównego Lekarza Weterynarii z dnia 25 czerwca 2003 r. Nr GIW z VII. 420/lab – 3/2003","norm_bases":["Instrukcja Nr 26/2003 Głównego Lekarza Weterynarii z dnia 25 czerwca 2003 r. Nr GIW z VII. 420/lab – 3/2003"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Surowica krwi bydła Obecność przeciwciał przeciwko Brucella spp.\nMetoda odczynu aglutynacji probówkowej (OA) Instrukcja Nr 26/2003 Głównego Lekarza Weterynarii z dnia 25 czerwca 2003 r. Nr GIW z VII. 420/lab – 3/2003 Surowica krwi bydla Obecnosc przeciwcial przeciwko Brucella spp.\nMetoda odczynu aglutynacji probowkowej (OA) Instrukcja Nr 26/2003 Glownego Lekarza Weterynarii z dnia 25 czerwca 2003 r. Nr GIW z VII. 420/lab – 3/2003","categories":["other"],"row_index":54,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cattle blood serum Presence of antibodies against Brucella spp. Tube agglutination test (OA) Instrukcja Nr 26/2003 Głównego Lekarza Weterynarii z dnia 25 czerwca 2003 r. Nr GIW z VII. 420/lab – 3/2003","search_zh":"牛血清 布鲁氏菌属（Brucella spp.）抗体的检出 试管凝集试验法（OA） Instrukcja Nr 26/2003 Głównego Lekarza Weterynarii z dnia 25 czerwca 2003 r. Nr GIW z VII. 420/lab – 3/2003","test_object_zh":"牛血清","technique_zh":"试管凝集试验法（OA）","methodology_zh":"布鲁氏菌属（Brucella spp.）抗体的检出"},{"_id":"6a5e78434cc76d93cba3acfb","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Surowica krwi zwierząt 1)","test_object_en":"Animal blood serum 1)","methodology":"Obecność przeciwciał 2)","methodology_en":"Presence of antibodies 2)","parameters":[],"parameters_en":[],"technique":"Metoda odczynu wiązania dopełniacza (OWD)","techniques":["Metoda odczynu wiązania dopełniacza (OWD)"],"technique_en":"Complement fixation test method (OWD)","computed":[],"computed_en":[],"activity":"Obecność przeciwciał 2)\nMetoda odczynu wiązania dopełniacza (OWD)","reference":"Instrukcja Głównego Lekarza Weterynarii 3)","norm_bases":["Instrukcja Głównego Lekarza Weterynarii 3)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Surowica krwi zwierząt 1) Obecność przeciwciał 2)\nMetoda odczynu wiązania dopełniacza (OWD) Instrukcja Głównego Lekarza Weterynarii 3) Surowica krwi zwierzat 1) Obecnosc przeciwcial 2)\nMetoda odczynu wiazania dopelniacza (OWD) Instrukcja Glownego Lekarza Weterynarii 3)","categories":["other"],"row_index":55,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Animal blood serum 1) Presence of antibodies 2) Complement fixation test method (OWD) Instrukcja Głównego Lekarza Weterynarii 3)","search_zh":"动物血清 1) 抗体 2) 的检出 补体结合试验法（OWD） Instrukcja Głównego Lekarza Weterynarii 3)","technique_zh":"补体结合试验法（OWD）","methodology_zh":"抗体 2) 的检出","test_object_zh":"动物血清 1)"},{"_id":"6a5e78434cc76d93cba3acfc","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Surowica krwi zwierząt 1)","test_object_en":"Animal blood serum 1)","methodology":"Obecność przeciwciał 2)","methodology_en":"Presence of antibodies 2)","parameters":[],"parameters_en":[],"technique":"Metoda immunoenzymatyczna (ELISA)","techniques":["Metoda immunoenzymatyczna (ELISA)"],"technique_en":"Enzyme immunoassay method (ELISA)","computed":[],"computed_en":[],"activity":"Obecność przeciwciał 2)\nMetoda immunoenzymatyczna (ELISA)","reference":"Instrukcje Głównego Lekarza Weterynarii 3) Procedury badawcze 4)","norm_bases":["Instrukcje Głównego Lekarza Weterynarii 3) Procedury badawcze 4)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Surowica krwi zwierząt 1) Obecność przeciwciał 2)\nMetoda immunoenzymatyczna (ELISA) Instrukcje Głównego Lekarza Weterynarii 3) Procedury badawcze 4) Surowica krwi zwierzat 1) Obecnosc przeciwcial 2)\nMetoda immunoenzymatyczna (ELISA) Instrukcje Glownego Lekarza Weterynarii 3) Procedury badawcze 4)","categories":["other"],"row_index":56,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Animal blood serum 1) Presence of antibodies 2) Enzyme immunoassay method (ELISA) Instrukcje Głównego Lekarza Weterynarii 3) Procedury badawcze 4)","search_zh":"动物血清 1) 抗体 2) 的检出 酶联免疫吸附法（ELISA） Instrukcje Głównego Lekarza Weterynarii 3) Procedury badawcze 4)","technique_zh":"酶联免疫吸附法（ELISA）","methodology_zh":"抗体 2) 的检出","test_object_zh":"动物血清 1)"},{"_id":"6a5e78434cc76d93cba3acfd","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Materiał biologiczny, Żywność, Obiekty z obszaru produkcji żywności 1)","test_object_en":"Biological material, Food, Objects from the food production area 1)","methodology":"Obecność materiału genetycznego 2)","methodology_en":"Presence of genetic material 2)","parameters":[],"parameters_en":[],"technique":"Metoda real-time PCR / real-time RT- PCR","techniques":["Metoda real-time PCR / real-time RT- PCR"],"technique_en":"Real-time PCR / real-time RT- PCR method","computed":[],"computed_en":[],"activity":"Obecność materiału genetycznego 2)\nMetoda real-time PCR / real-time RT- PCR","reference":"Instrukcja Głównego Lekarza Weterynarii 3) Procedury badawcze 4)","norm_bases":["Instrukcja Głównego Lekarza Weterynarii 3) Procedury badawcze 4)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiał biologiczny, Żywność, Obiekty z obszaru produkcji żywności 1) Obecność materiału genetycznego 2)\nMetoda real-time PCR / real-time RT- PCR Instrukcja Głównego Lekarza Weterynarii 3) Procedury badawcze 4) Material biologiczny, Zywnosc, Obiekty z obszaru produkcji zywnosci 1) Obecnosc materialu genetycznego 2)\nMetoda real-time PCR / real-time RT- PCR Instrukcja Glownego Lekarza Weterynarii 3) Procedury badawcze 4)","categories":["food","materials"],"row_index":57,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Biological material, Food, Objects from the food production area 1) Presence of genetic material 2) Real-time PCR / real-time RT- PCR method Instrukcja Głównego Lekarza Weterynarii 3) Procedury badawcze 4)"},{"_id":"6a5e78434cc76d93cba3acfe","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Mózgowie zwierząt","test_object_en":"Animal brain tissue","methodology":"Obecność antygenu lyssawirusa","methodology_en":"Presence of lyssavirus antigen","parameters":[],"parameters_en":[],"technique":"Metoda immunofluorescencji bezpośredniej","techniques":["Metoda immunofluorescencji bezpośredniej"],"technique_en":"Direct immunofluorescence method","computed":[],"computed_en":[],"activity":"Obecność antygenu lyssawirusa\nMetoda immunofluorescencji bezpośredniej","reference":"Instrukcja Głównego Lekarza Weterynarii Nr GIWpr-02010-3/2018 z dnia 7 lutego 2018 r.","norm_bases":["Instrukcja Głównego Lekarza Weterynarii Nr GIWpr-02010-3/2018 z dnia 7 lutego 2018 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mózgowie zwierząt Obecność antygenu lyssawirusa\nMetoda immunofluorescencji bezpośredniej Instrukcja Głównego Lekarza Weterynarii Nr GIWpr-02010-3/2018 z dnia 7 lutego 2018 r. Mozgowie zwierzat Obecnosc antygenu lyssawirusa\nMetoda immunofluorescencji bezposredniej Instrukcja Glownego Lekarza Weterynarii Nr GIWpr-02010-3/2018 z dnia 7 lutego 2018 r.","categories":["other"],"row_index":58,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Animal brain tissue Presence of lyssavirus antigen Direct immunofluorescence method Instrukcja Głównego Lekarza Weterynarii Nr GIWpr-02010-3/2018 z dnia 7 lutego 2018 r.","methodology_zh":"狂犬病病毒抗原的检出","search_zh":"动物脑组织 狂犬病病毒抗原的检出 直接免疫荧光法 Instrukcja Głównego Lekarza Weterynarii Nr GIWpr-02010-3/2018 z dnia 7 lutego 2018 r.","test_object_zh":"动物脑组织","technique_zh":"直接免疫荧光法"},{"_id":"6a5e78434cc76d93cba3acff","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Szlif kostny pochodzący od lisów wolnożyjących","test_object_en":"Bone section from free-living foxes","methodology":"Obecność tetracykliny","methodology_en":"Presence of tetracycline","parameters":[],"parameters_en":[],"technique":"Metoda mikroskopowa","techniques":["Metoda mikroskopowa"],"technique_en":"Microscopic method","computed":[],"computed_en":[],"activity":"Obecność tetracykliny\nMetoda mikroskopowa","reference":"Instrukcja Głównego Lekarza Weterynarii Nr GIWpr-02010-36/2016 z dnia 12 grudnia 2016 r.","norm_bases":["Instrukcja Głównego Lekarza Weterynarii Nr GIWpr-02010-36/2016 z dnia 12 grudnia 2016 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Szlif kostny pochodzący od lisów wolnożyjących Obecność tetracykliny\nMetoda mikroskopowa Instrukcja Głównego Lekarza Weterynarii Nr GIWpr-02010-36/2016 z dnia 12 grudnia 2016 r. Szlif kostny pochodzacy od lisow wolnozyjacych Obecnosc tetracykliny\nMetoda mikroskopowa Instrukcja Glownego Lekarza Weterynarii Nr GIWpr-02010-36/2016 z dnia 12 grudnia 2016 r.","categories":["other"],"row_index":59,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Bone section from free-living foxes Presence of tetracycline Microscopic method Instrukcja Głównego Lekarza Weterynarii Nr GIWpr-02010-36/2016 z dnia 12 grudnia 2016 r.","search_zh":"显微镜法 Instrukcja Głównego Lekarza Weterynarii Nr GIWpr-02010-36/2016 z dnia 12 grudnia 2016 r.","technique_zh":"显微镜法"},{"_id":"6a5e78434cc76d93cba3ad00","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Mózgowie zwierząt","test_object_en":"Animal brain tissue","methodology":"Obecność lyssawirusa","methodology_en":"Presence of lyssavirus","parameters":[],"parameters_en":[],"technique":"Metoda izolacji lyssawirusa w hodowli komórek mysiej neuroblastomy","techniques":["Metoda izolacji lyssawirusa w hodowli komórek mysiej neuroblastomy"],"technique_en":"Lyssavirus isolation in mouse neuroblastoma cell culture","computed":[],"computed_en":[],"activity":"Obecność lyssawirusa\nMetoda izolacji lyssawirusa w hodowli komórek mysiej neuroblastomy","reference":"Instrukcja Głównego Lekarza Weterynarii Nr GIWpr-02010-38/2016 z dnia 12 grudnia 2016 r.","norm_bases":["Instrukcja Głównego Lekarza Weterynarii Nr GIWpr-02010-38/2016 z dnia 12 grudnia 2016 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mózgowie zwierząt Obecność lyssawirusa\nMetoda izolacji lyssawirusa w hodowli komórek mysiej neuroblastomy Instrukcja Głównego Lekarza Weterynarii Nr GIWpr-02010-38/2016 z dnia 12 grudnia 2016 r. Mozgowie zwierzat Obecnosc lyssawirusa\nMetoda izolacji lyssawirusa w hodowli komorek mysiej neuroblastomy Instrukcja Glownego Lekarza Weterynarii Nr GIWpr-02010-38/2016 z dnia 12 grudnia 2016 r.","categories":["construction"],"row_index":60,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Animal brain tissue Presence of lyssavirus Lyssavirus isolation in mouse neuroblastoma cell culture Instrukcja Głównego Lekarza Weterynarii Nr GIWpr-02010-38/2016 z dnia 12 grudnia 2016 r.","methodology_zh":"狂犬病病毒的检出","search_zh":"动物脑组织 狂犬病病毒的检出 在小鼠神经母细胞瘤细胞培养物中分离狂犬病病毒的方法 Instrukcja Głównego Lekarza Weterynarii Nr GIWpr-02010-38/2016 z dnia 12 grudnia 2016 r.","test_object_zh":"动物脑组织","technique_zh":"在小鼠神经母细胞瘤细胞培养物中分离狂犬病病毒的方法"},{"_id":"6a5e78434cc76d93cba3ad01","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Surowica, Plazma, Płyny z jam ciała","test_object_en":"Serum, Plasma, Body cavity fluids","methodology":"Obecność przeciwciał przeciwko wirusowi wścieklizny","methodology_en":"Presence of antibodies against rabies virus","parameters":[],"parameters_en":[],"technique":"Metoda immunoenzymatyczna (ELISA)","techniques":["Metoda immunoenzymatyczna (ELISA)"],"technique_en":"Enzyme immunoassay method (ELISA)","computed":[],"computed_en":[],"activity":"Obecność przeciwciał przeciwko wirusowi wścieklizny\nMetoda immunoenzymatyczna (ELISA)","reference":"Instrukcja Głównego Lekarza Weterynarii Nr GIWpr-02010-35/2016 z dnia 12 grudnia 2016 r.","norm_bases":["Instrukcja Głównego Lekarza Weterynarii Nr GIWpr-02010-35/2016 z dnia 12 grudnia 2016 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Surowica, Plazma, Płyny z jam ciała Obecność przeciwciał przeciwko wirusowi wścieklizny\nMetoda immunoenzymatyczna (ELISA) Instrukcja Głównego Lekarza Weterynarii Nr GIWpr-02010-35/2016 z dnia 12 grudnia 2016 r. Surowica, Plazma, Plyny z jam ciala Obecnosc przeciwcial przeciwko wirusowi wscieklizny\nMetoda immunoenzymatyczna (ELISA) Instrukcja Glownego Lekarza Weterynarii Nr GIWpr-02010-35/2016 z dnia 12 grudnia 2016 r.","categories":["other"],"row_index":61,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Serum, Plasma, Body cavity fluids Presence of antibodies against rabies virus Enzyme immunoassay method (ELISA) Instrukcja Głównego Lekarza Weterynarii Nr GIWpr-02010-35/2016 z dnia 12 grudnia 2016 r.","search_zh":"狂犬病病毒抗体的检出 酶联免疫吸附法（ELISA） Instrukcja Głównego Lekarza Weterynarii Nr GIWpr-02010-35/2016 z dnia 12 grudnia 2016 r.","technique_zh":"酶联免疫吸附法（ELISA）","methodology_zh":"狂犬病病毒抗体的检出"},{"_id":"6a5e78434cc76d93cba3ad02","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Mięso surowe świń, dzików i koni","test_object_en":"Raw meat of pigs, wild boars and horses","methodology":"Obecność włośni (Trichinella) metoda wytrawiania próbki zbiorczej z zastosowaniem metody magnetycznego mieszania","methodology_en":"Presence of trichinae (Trichinella) magnetic stirring method of digestion of a pooled sample","parameters":[],"parameters_en":[],"technique":"Metoda referencyjna","techniques":["Metoda referencyjna"],"technique_en":"Reference method","computed":[],"computed_en":[],"activity":"Obecność włośni (Trichinella) metoda wytrawiania próbki zbiorczej z zastosowaniem metody magnetycznego mieszania\nMetoda referencyjna","reference":"PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2)","norm_bases":["PN-EN ISO 18743 1)","Instrukcja Głównego Lekarza Weterynarii 2)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mięso surowe świń, dzików i koni Obecność włośni (Trichinella) metoda wytrawiania próbki zbiorczej z zastosowaniem metody magnetycznego mieszania\nMetoda referencyjna PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2) Mieso surowe swin, dzikow i koni Obecnosc wlosni (Trichinella) metoda wytrawiania probki zbiorczej z zastosowaniem metody magnetycznego mieszania\nMetoda referencyjna PN-EN ISO 18743 1) | Instrukcja Glownego Lekarza Weterynarii 2)","categories":["food"],"row_index":62,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Raw meat of pigs, wild boars and horses Presence of trichinae (Trichinella) magnetic stirring method of digestion of a pooled sample Reference method PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2)","search_zh":"猪、野猪与马的生鲜肉 旋毛虫（Trichinella）的检出 混合样品磁力搅拌消化法 基准方法 PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2)","technique_zh":"基准方法","methodology_zh":"旋毛虫（Trichinella）的检出 混合样品磁力搅拌消化法","test_object_zh":"猪、野猪与马的生鲜肉"},{"_id":"6a5e78434cc76d93cba3ad03","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Mięso surowe świń, dzików i koni","test_object_en":"Raw meat of pigs, wild boars and horses","methodology":"Obecność włośni (Trichinella) metoda wytrawiania próbki zbiorczej z zastosowaniem metody magnetycznego mieszania","methodology_en":"Presence of trichinae (Trichinella) magnetic stirring method of digestion of a pooled sample","parameters":[],"parameters_en":[],"technique":"Metoda referencyjna","techniques":["Metoda referencyjna"],"technique_en":"Reference method","computed":[],"computed_en":[],"activity":"Obecność włośni (Trichinella) metoda wytrawiania próbki zbiorczej z zastosowaniem metody magnetycznego mieszania\nMetoda referencyjna","reference":"PN-EN ISO 187431) | Instrukcja Głównego Lekarza Weterynarii 2)","norm_bases":["PN-EN ISO 187431)","Instrukcja Głównego Lekarza Weterynarii 2)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mięso surowe świń, dzików i koni Obecność włośni (Trichinella) metoda wytrawiania próbki zbiorczej z zastosowaniem metody magnetycznego mieszania\nMetoda referencyjna PN-EN ISO 187431) | Instrukcja Głównego Lekarza Weterynarii 2) Mieso surowe swin, dzikow i koni Obecnosc wlosni (Trichinella) metoda wytrawiania probki zbiorczej z zastosowaniem metody magnetycznego mieszania\nMetoda referencyjna PN-EN ISO 187431) | Instrukcja Glownego Lekarza Weterynarii 2)","categories":["food"],"row_index":63,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Raw meat of pigs, wild boars and horses Presence of trichinae (Trichinella) magnetic stirring method of digestion of a pooled sample Reference method PN-EN ISO 187431) | Instrukcja Głównego Lekarza Weterynarii 2)","search_zh":"猪、野猪与马的生鲜肉 旋毛虫（Trichinella）的检出 混合样品磁力搅拌消化法 基准方法 PN-EN ISO 187431) | Instrukcja Głównego Lekarza Weterynarii 2)","technique_zh":"基准方法","methodology_zh":"旋毛虫（Trichinella）的检出 混合样品磁力搅拌消化法","test_object_zh":"猪、野猪与马的生鲜肉"},{"_id":"6a5e78434cc76d93cba3ad04","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Mięso surowe świń i dzików","test_object_en":"Raw meat of pigs and wild boars","methodology":"Obecność włośni (Trichinella) metoda wytrawiania próbki zbiorczej z zastosowaniem metody magnetycznego mieszania","methodology_en":"Presence of trichinae (Trichinella) magnetic stirring method of digestion of a pooled sample","parameters":[],"parameters_en":[],"technique":"Metoda referencyjna","techniques":["Metoda referencyjna"],"technique_en":"Reference method","computed":[],"computed_en":[],"activity":"Obecność włośni (Trichinella) metoda wytrawiania próbki zbiorczej z zastosowaniem metody magnetycznego mieszania\nMetoda referencyjna","reference":"PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2)","norm_bases":["PN-EN ISO 18743 1)","Instrukcja Głównego Lekarza Weterynarii 2)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mięso surowe świń i dzików Obecność włośni (Trichinella) metoda wytrawiania próbki zbiorczej z zastosowaniem metody magnetycznego mieszania\nMetoda referencyjna PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2) Mieso surowe swin i dzikow Obecnosc wlosni (Trichinella) metoda wytrawiania probki zbiorczej z zastosowaniem metody magnetycznego mieszania\nMetoda referencyjna PN-EN ISO 18743 1) | Instrukcja Glownego Lekarza Weterynarii 2)","categories":["food"],"row_index":64,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Raw meat of pigs and wild boars Presence of trichinae (Trichinella) magnetic stirring method of digestion of a pooled sample Reference method PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2)","search_zh":"猪和野猪生肉 旋毛虫（Trichinella）的检出 混合样品磁力搅拌消化法 基准方法 PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2)","technique_zh":"基准方法","test_object_zh":"猪和野猪生肉","methodology_zh":"旋毛虫（Trichinella）的检出 混合样品磁力搅拌消化法"},{"_id":"6a5e78434cc76d93cba3ad05","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Mięso surowe świń i dzików","test_object_en":"Raw meat of pigs and wild boars","methodology":"Obecność włośni (Trichinella) metoda wytrawiania próbki zbiorczej z zastosowaniem metody magnetycznego mieszania","methodology_en":"Presence of trichinae (Trichinella) magnetic stirring method of digestion of a pooled sample","parameters":[],"parameters_en":[],"technique":"Metoda referencyjna","techniques":["Metoda referencyjna"],"technique_en":"Reference method","computed":[],"computed_en":[],"activity":"Obecność włośni (Trichinella) metoda wytrawiania próbki zbiorczej z zastosowaniem metody magnetycznego mieszania\nMetoda referencyjna","reference":"PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2)","norm_bases":["PN-EN ISO 18743 1)","Instrukcja Głównego Lekarza Weterynarii 2)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mięso surowe świń i dzików Obecność włośni (Trichinella) metoda wytrawiania próbki zbiorczej z zastosowaniem metody magnetycznego mieszania\nMetoda referencyjna PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2) Mieso surowe swin i dzikow Obecnosc wlosni (Trichinella) metoda wytrawiania probki zbiorczej z zastosowaniem metody magnetycznego mieszania\nMetoda referencyjna PN-EN ISO 18743 1) | Instrukcja Glownego Lekarza Weterynarii 2)","categories":["food"],"row_index":65,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Raw meat of pigs and wild boars Presence of trichinae (Trichinella) magnetic stirring method of digestion of a pooled sample Reference method PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2)","search_zh":"猪和野猪生肉 旋毛虫（Trichinella）的检出 混合样品磁力搅拌消化法 基准方法 PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2)","technique_zh":"基准方法","test_object_zh":"猪和野猪生肉","methodology_zh":"旋毛虫（Trichinella）的检出 混合样品磁力搅拌消化法"},{"_id":"6a5e78434cc76d93cba3ad06","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Mięso surowe świń i dzików","test_object_en":"Raw meat of pigs and wild boars","methodology":"Obecność włośni (Trichinella) metoda wytrawiania próbki zbiorczej z zastosowaniem metody magnetycznego mieszania","methodology_en":"Presence of trichinae (Trichinella) magnetic stirring method of digestion of a pooled sample","parameters":[],"parameters_en":[],"technique":"Metoda referencyjna","techniques":["Metoda referencyjna"],"technique_en":"Reference method","computed":[],"computed_en":[],"activity":"Obecność włośni (Trichinella) metoda wytrawiania próbki zbiorczej z zastosowaniem metody magnetycznego mieszania\nMetoda referencyjna","reference":"PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2)","norm_bases":["PN-EN ISO 18743 1)","Instrukcja Głównego Lekarza Weterynarii 2)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mięso surowe świń i dzików Obecność włośni (Trichinella) metoda wytrawiania próbki zbiorczej z zastosowaniem metody magnetycznego mieszania\nMetoda referencyjna PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2) Mieso surowe swin i dzikow Obecnosc wlosni (Trichinella) metoda wytrawiania probki zbiorczej z zastosowaniem metody magnetycznego mieszania\nMetoda referencyjna PN-EN ISO 18743 1) | Instrukcja Glownego Lekarza Weterynarii 2)","categories":["food"],"row_index":66,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Raw meat of pigs and wild boars Presence of trichinae (Trichinella) magnetic stirring method of digestion of a pooled sample Reference method PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2)","search_zh":"猪和野猪生肉 旋毛虫（Trichinella）的检出 混合样品磁力搅拌消化法 基准方法 PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2)","technique_zh":"基准方法","test_object_zh":"猪和野猪生肉","methodology_zh":"旋毛虫（Trichinella）的检出 混合样品磁力搅拌消化法"},{"_id":"6a5e78434cc76d93cba3ad07","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Mięso surowe świń i dzików","test_object_en":"Raw meat of pigs and wild boars","methodology":"Obecność włośni (Trichinella) metoda wytrawiania próbki zbiorczej z zastosowaniem metody magnetycznego mieszania","methodology_en":"Presence of trichinae (Trichinella) magnetic stirring method of digestion of a pooled sample","parameters":[],"parameters_en":[],"technique":"Metoda referencyjna","techniques":["Metoda referencyjna"],"technique_en":"Reference method","computed":[],"computed_en":[],"activity":"Obecność włośni (Trichinella) metoda wytrawiania próbki zbiorczej z zastosowaniem metody magnetycznego mieszania\nMetoda referencyjna","reference":"PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2)","norm_bases":["PN-EN ISO 18743 1)","Instrukcja Głównego Lekarza Weterynarii 2)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mięso surowe świń i dzików Obecność włośni (Trichinella) metoda wytrawiania próbki zbiorczej z zastosowaniem metody magnetycznego mieszania\nMetoda referencyjna PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2) Mieso surowe swin i dzikow Obecnosc wlosni (Trichinella) metoda wytrawiania probki zbiorczej z zastosowaniem metody magnetycznego mieszania\nMetoda referencyjna PN-EN ISO 18743 1) | Instrukcja Glownego Lekarza Weterynarii 2)","categories":["food"],"row_index":67,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Raw meat of pigs and wild boars Presence of trichinae (Trichinella) magnetic stirring method of digestion of a pooled sample Reference method PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2)","search_zh":"猪和野猪生肉 旋毛虫（Trichinella）的检出 混合样品磁力搅拌消化法 基准方法 PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2)","technique_zh":"基准方法","test_object_zh":"猪和野猪生肉","methodology_zh":"旋毛虫（Trichinella）的检出 混合样品磁力搅拌消化法"},{"_id":"6a5e78434cc76d93cba3ad08","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Mleko surowe","test_object_en":"Raw milk","methodology":"Ogólna liczba drobnoustrojów","methodology_en":"Total viable count","parameters":[{"name":"(od 1x103do 6x105 ) CFU/1ml"}],"parameters_en":[{"name":"(from 1x103to 6x105 ) CFU/1ml"}],"technique":"Metoda cytometrii przepływowej","techniques":["Metoda cytometrii przepływowej"],"technique_en":"Flow cytometry method","computed":[],"computed_en":[],"activity":"Ogólna liczba drobnoustrojów\n(od 1x103do 6x105 ) CFU/1ml\nMetoda cytometrii przepływowej","reference":"PB-01/ML_OTS Wydanie 10 z 22.01.2018 r. w oparciu o instrukcję aparatu Bactocount IBC","norm_bases":["PB-01/ML_OTS Wydanie 10 z 22.01.2018 r. w oparciu o instrukcję aparatu Bactocount IBC"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mleko surowe Ogólna liczba drobnoustrojów\n(od 1x103do 6x105 ) CFU/1ml\nMetoda cytometrii przepływowej PB-01/ML_OTS Wydanie 10 z 22.01.2018 r. w oparciu o instrukcję aparatu Bactocount IBC Mleko surowe Ogolna liczba drobnoustrojow\n(od 1x103do 6x105 ) CFU/1ml\nMetoda cytometrii przeplywowej PB-01/ML_OTS Wydanie 10 z 22.01.2018 r. w oparciu o instrukcje aparatu Bactocount IBC","categories":["food","microbiology"],"row_index":68,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Raw milk Total viable count Flow cytometry method (from 1x103to 6x105 ) CFU/1ml PB-01/ML_OTS Wydanie 10 z 22.01.2018 r. w oparciu o instrukcję aparatu Bactocount IBC","methodology_zh":"微生物总数","search_zh":"生乳 微生物总数 流式细胞术 PB-01/ML_OTS Wydanie 10 z 22.01.2018 r. w oparciu o instrukcję aparatu Bactocount IBC","technique_zh":"流式细胞术","test_object_zh":"生乳"},{"_id":"6a5e78434cc76d93cba3ad09","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Mleko surowe","test_object_en":"Raw milk","methodology":"Liczba komórek somatycznych","methodology_en":"Somatic cell count","parameters":[{"name":"(od 1x103 do 18x105 ) komórek/1ml"}],"parameters_en":[{"name":"(from 1x103 to 18x105 ) cells/1ml"}],"technique":"Metoda cytometrii przepływowej","techniques":["Metoda cytometrii przepływowej"],"technique_en":"Flow cytometry method","computed":[],"computed_en":[],"activity":"Liczba komórek somatycznych\n(od 1x103 do 18x105 ) komórek/1ml\nMetoda cytometrii przepływowej","reference":"PN-EN ISO 13366 – 2:2007 z zastosowaniem aparatu Dairy Spec FT Combi","norm_bases":["PN-EN ISO 13366 – 2:2007 z zastosowaniem aparatu Dairy Spec FT Combi"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mleko surowe Liczba komórek somatycznych\n(od 1x103 do 18x105 ) komórek/1ml\nMetoda cytometrii przepływowej PN-EN ISO 13366 – 2:2007 z zastosowaniem aparatu Dairy Spec FT Combi Mleko surowe Liczba komorek somatycznych\n(od 1x103 do 18x105 ) komorek/1ml\nMetoda cytometrii przeplywowej PN-EN ISO 13366 – 2:2007 z zastosowaniem aparatu Dairy Spec FT Combi","categories":["food"],"row_index":69,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Raw milk Somatic cell count Flow cytometry method (from 1x103 to 18x105 ) cells/1ml PN-EN ISO 13366 – 2:2007 z zastosowaniem aparatu Dairy Spec FT Combi","methodology_zh":"体细胞计数","search_zh":"生乳 体细胞计数 流式细胞术 PN-EN ISO 13366 – 2:2007 z zastosowaniem aparatu Dairy Spec FT Combi","technique_zh":"流式细胞术","test_object_zh":"生乳"},{"_id":"6a5e78434cc76d93cba3ad0a","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Mleko surowe","test_object_en":"Raw milk","methodology":"Zawartość białka","methodology_en":"Protein content","parameters":[{"name":"(od 2,50 do 4,00) %"}],"parameters_en":[{"name":"(from 2,50 to 4,00) %"}],"technique":"Metoda spektrometrii w podczerwieni","techniques":["Metoda spektrometrii w podczerwieni"],"technique_en":"Infrared spectrometry method","computed":[],"computed_en":[],"activity":"Zawartość białka\n(od 2,50 do 4,00) %\nMetoda spektrometrii w podczerwieni","reference":"PN-ISO 9622:2015-09 z zastosowaniem aparatu Dairy Spec FT Combi","norm_bases":["PN-ISO 9622:2015-09 z zastosowaniem aparatu Dairy Spec FT Combi"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mleko surowe Zawartość białka\n(od 2,50 do 4,00) %\nMetoda spektrometrii w podczerwieni PN-ISO 9622:2015-09 z zastosowaniem aparatu Dairy Spec FT Combi Mleko surowe Zawartosc bialka\n(od 2,50 do 4,00) %\nMetoda spektrometrii w podczerwieni PN-ISO 9622:2015-09 z zastosowaniem aparatu Dairy Spec FT Combi","categories":["food"],"row_index":70,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Raw milk Protein content Infrared spectrometry method (from 2,50 to 4,00) % PN-ISO 9622:2015-09 z zastosowaniem aparatu Dairy Spec FT Combi","methodology_zh":"蛋白质含量","search_zh":"生乳 蛋白质含量 红外光谱法 PN-ISO 9622:2015-09 z zastosowaniem aparatu Dairy Spec FT Combi","technique_zh":"红外光谱法","test_object_zh":"生乳"},{"_id":"6a5e78434cc76d93cba3ad0b","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Mleko surowe","test_object_en":"Raw milk","methodology":"Zawartość tłuszczu","methodology_en":"Fat content","parameters":[{"name":"(od 2,50 do 5,00 )%"}],"parameters_en":[{"name":"(from 2,50 to 5,00 )%"}],"technique":"Metoda spektrometrii w podczerwieni","techniques":["Metoda spektrometrii w podczerwieni"],"technique_en":"Infrared spectrometry method","computed":[],"computed_en":[],"activity":"Zawartość tłuszczu\n(od 2,50 do 5,00 )%\nMetoda spektrometrii w podczerwieni","reference":"PN-ISO 9622:2015-09 z zastosowaniem aparatu Dairy Spec FT Combi","norm_bases":["PN-ISO 9622:2015-09 z zastosowaniem aparatu Dairy Spec FT Combi"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mleko surowe Zawartość tłuszczu\n(od 2,50 do 5,00 )%\nMetoda spektrometrii w podczerwieni PN-ISO 9622:2015-09 z zastosowaniem aparatu Dairy Spec FT Combi Mleko surowe Zawartosc tluszczu\n(od 2,50 do 5,00 )%\nMetoda spektrometrii w podczerwieni PN-ISO 9622:2015-09 z zastosowaniem aparatu Dairy Spec FT Combi","categories":["food"],"row_index":71,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Raw milk Fat content Infrared spectrometry method (from 2,50 to 5,00 )% PN-ISO 9622:2015-09 z zastosowaniem aparatu Dairy Spec FT Combi","methodology_zh":"脂肪含量","search_zh":"生乳 脂肪含量 红外光谱法 PN-ISO 9622:2015-09 z zastosowaniem aparatu Dairy Spec FT Combi","technique_zh":"红外光谱法","test_object_zh":"生乳"},{"_id":"6a5e78434cc76d93cba3ad0c","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Mleko surowe","test_object_en":"Raw milk","methodology":"Zawartość mocznika","methodology_en":"Urea content","parameters":[{"name":"(od 150 do 500)mg/l"}],"parameters_en":[{"name":"(from 150 to 500)mg/l"}],"technique":"Metoda spektrometrii w podczerwieni","techniques":["Metoda spektrometrii w podczerwieni"],"technique_en":"Infrared spectrometry method","computed":[],"computed_en":[],"activity":"Zawartość mocznika\n(od 150 do 500)mg/l\nMetoda spektrometrii w podczerwieni","reference":"PN-ISO 9622:2015-09 z zastosowaniem aparatu Dairy Spec FT Combi","norm_bases":["PN-ISO 9622:2015-09 z zastosowaniem aparatu Dairy Spec FT Combi"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mleko surowe Zawartość mocznika\n(od 150 do 500)mg/l\nMetoda spektrometrii w podczerwieni PN-ISO 9622:2015-09 z zastosowaniem aparatu Dairy Spec FT Combi Mleko surowe Zawartosc mocznika\n(od 150 do 500)mg/l\nMetoda spektrometrii w podczerwieni PN-ISO 9622:2015-09 z zastosowaniem aparatu Dairy Spec FT Combi","categories":["food"],"row_index":72,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Raw milk Urea content Infrared spectrometry method (from 150 to 500)mg/l PN-ISO 9622:2015-09 z zastosowaniem aparatu Dairy Spec FT Combi","search_zh":"生乳 尿素含量 红外光谱法 PN-ISO 9622:2015-09 z zastosowaniem aparatu Dairy Spec FT Combi","technique_zh":"红外光谱法","test_object_zh":"生乳","methodology_zh":"尿素含量"},{"_id":"6a5e78434cc76d93cba3ad0d","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Mleko surowe","test_object_en":"Raw milk","methodology":"Zawartość laktozy","methodology_en":"Lactose content","parameters":[{"name":"(od 4,2 do 5,0)%"}],"parameters_en":[{"name":"(from 4,2 to 5,0)%"}],"technique":"Metoda spektrometrii w podczerwieni","techniques":["Metoda spektrometrii w podczerwieni"],"technique_en":"Infrared spectrometry method","computed":[],"computed_en":[],"activity":"Zawartość laktozy\n(od 4,2 do 5,0)%\nMetoda spektrometrii w podczerwieni","reference":"PN-ISO 9622:2015-09 z zastosowaniem aparatu Dairy Spec FT Combi","norm_bases":["PN-ISO 9622:2015-09 z zastosowaniem aparatu Dairy Spec FT Combi"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mleko surowe Zawartość laktozy\n(od 4,2 do 5,0)%\nMetoda spektrometrii w podczerwieni PN-ISO 9622:2015-09 z zastosowaniem aparatu Dairy Spec FT Combi Mleko surowe Zawartosc laktozy\n(od 4,2 do 5,0)%\nMetoda spektrometrii w podczerwieni PN-ISO 9622:2015-09 z zastosowaniem aparatu Dairy Spec FT Combi","categories":["food"],"row_index":73,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Raw milk Lactose content Infrared spectrometry method (from 4,2 to 5,0)% PN-ISO 9622:2015-09 z zastosowaniem aparatu Dairy Spec FT Combi","search_zh":"生乳 乳糖含量 红外光谱法 PN-ISO 9622:2015-09 z zastosowaniem aparatu Dairy Spec FT Combi","technique_zh":"红外光谱法","test_object_zh":"生乳","methodology_zh":"乳糖含量"},{"_id":"6a5e78434cc76d93cba3ad0e","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Mleko surowe","test_object_en":"Raw milk","methodology":"Punkt zamarzania","methodology_en":"Freezing point","parameters":[{"name":"(od -0,550 do -0,450)oC"}],"parameters_en":[{"name":"(from -0,550 to -0,450)oC"}],"technique":"Metoda spektrometrii w podczerwieni","techniques":["Metoda spektrometrii w podczerwieni"],"technique_en":"Infrared spectrometry method","computed":[],"computed_en":[],"activity":"Punkt zamarzania\n(od -0,550 do -0,450)oC\nMetoda spektrometrii w podczerwieni","reference":"PN-ISO 9622:2015-09 z zastosowaniem aparatu Dairy Spec FT Combi","norm_bases":["PN-ISO 9622:2015-09 z zastosowaniem aparatu Dairy Spec FT Combi"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mleko surowe Punkt zamarzania\n(od -0,550 do -0,450)oC\nMetoda spektrometrii w podczerwieni PN-ISO 9622:2015-09 z zastosowaniem aparatu Dairy Spec FT Combi Mleko surowe Punkt zamarzania\n(od -0,550 do -0,450)oC\nMetoda spektrometrii w podczerwieni PN-ISO 9622:2015-09 z zastosowaniem aparatu Dairy Spec FT Combi","categories":["food"],"row_index":74,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Raw milk Freezing point Infrared spectrometry method (from -0,550 to -0,450)oC PN-ISO 9622:2015-09 z zastosowaniem aparatu Dairy Spec FT Combi","search_zh":"生乳 冰点 红外光谱法 PN-ISO 9622:2015-09 z zastosowaniem aparatu Dairy Spec FT Combi","technique_zh":"红外光谱法","test_object_zh":"生乳","methodology_zh":"冰点"},{"_id":"6a5e78434cc76d93cba3ad0f","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Mleko surowe","test_object_en":"Raw milk","methodology":"Punkt zamarzania","methodology_en":"Freezing point","parameters":[{"name":"(-0,600 ÷ - 0,408)oC"}],"parameters_en":[{"name":"(-0,600 ÷ - 0,408)oC"}],"technique":"Metoda krioskopowa","techniques":["Metoda krioskopowa"],"technique_en":"Cryoscopic method","computed":[],"computed_en":[],"activity":"Punkt zamarzania\n(-0,600 ÷ - 0,408)oC\nMetoda krioskopowa","reference":"PN-EN ISO 5764:2010 z zastosowaniem aparatu CryoTouch 20","norm_bases":["PN-EN ISO 5764:2010 z zastosowaniem aparatu CryoTouch 20"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mleko surowe Punkt zamarzania\n(-0,600 ÷ - 0,408)oC\nMetoda krioskopowa PN-EN ISO 5764:2010 z zastosowaniem aparatu CryoTouch 20 Mleko surowe Punkt zamarzania\n(-0,600 ÷ - 0,408)oC\nMetoda krioskopowa PN-EN ISO 5764:2010 z zastosowaniem aparatu CryoTouch 20","categories":["food"],"row_index":75,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Raw milk Freezing point Cryoscopic method (-0,600 ÷ - 0,408)oC PN-EN ISO 5764:2010 z zastosowaniem aparatu CryoTouch 20","search_zh":"生乳 冰点 冰点法 PN-EN ISO 5764:2010 z zastosowaniem aparatu CryoTouch 20","test_object_zh":"生乳","technique_zh":"冰点法","methodology_zh":"冰点"},{"_id":"6a5e78434cc76d93cba3ad10","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Mleko surowe","test_object_en":"Raw milk","methodology":"Obecność antybiotyków i sulfonamidów","methodology_en":"Presence of antibiotics and sulfonamides","parameters":[],"parameters_en":[],"technique":"Metoda dyfuzyjna","techniques":["Metoda dyfuzyjna"],"technique_en":"Diffusion method","computed":[],"computed_en":[],"activity":"Obecność antybiotyków i sulfonamidów\nMetoda dyfuzyjna","reference":"PB-02/ML_OTS Wydanie 08 z 22.01.2018 r. w oparciu o instrukcję producenta testu DELVOTEST SP -NT","norm_bases":["PB-02/ML_OTS Wydanie 08 z 22.01.2018 r. w oparciu o instrukcję producenta testu DELVOTEST SP -NT"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mleko surowe Obecność antybiotyków i sulfonamidów\nMetoda dyfuzyjna PB-02/ML_OTS Wydanie 08 z 22.01.2018 r. w oparciu o instrukcję producenta testu DELVOTEST SP -NT Mleko surowe Obecnosc antybiotykow i sulfonamidow\nMetoda dyfuzyjna PB-02/ML_OTS Wydanie 08 z 22.01.2018 r. w oparciu o instrukcje producenta testu DELVOTEST SP -NT","categories":["food"],"row_index":76,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Raw milk Presence of antibiotics and sulfonamides Diffusion method PB-02/ML_OTS Wydanie 08 z 22.01.2018 r. w oparciu o instrukcję producenta testu DELVOTEST SP -NT","search_zh":"生乳 扩散法 PB-02/ML_OTS Wydanie 08 z 22.01.2018 r. w oparciu o instrukcję producenta testu DELVOTEST SP -NT","technique_zh":"扩散法","test_object_zh":"生乳"},{"_id":"6a5e78434cc76d93cba3ad11","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Mleko surowe","test_object_en":"Raw milk","methodology":"Zawartość azotu","methodology_en":"Nitrogen content","parameters":[{"name":"Zakres","range":"(0,400-0.600) %"},{"name":"Zawartość białka (z obliczeń)"}],"parameters_en":[{"name":"Range","range":"(0,400-0.600) %"},{"name":"Protein content (calculated)"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Zawartość azotu\nZakres:\nZakres (0,400-0.600) %\nZawartość białka (z obliczeń)\nMetoda miareczkowa","reference":"PN-EN ISO 8968-1:2014-03","norm_bases":["PN-EN ISO 8968-1:2014-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mleko surowe Zawartość azotu\nZakres:\nZakres (0,400-0.600) %\nZawartość białka (z obliczeń)\nMetoda miareczkowa PN-EN ISO 8968-1:2014-03 Mleko surowe Zawartosc azotu\nZakres:\nZakres (0,400-0.600) %\nZawartosc bialka (z obliczen)\nMetoda miareczkowa PN-EN ISO 8968-1:2014-03","categories":["food"],"row_index":77,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Raw milk Nitrogen content Titrimetric method Range Protein content (calculated) PN-EN ISO 8968-1:2014-03","methodology_zh":"氮含量","parameters_zh":[{"name":"范围","range":"(0,400-0.600) %"},{"name":"蛋白质含量（计算值）"}],"search_zh":"生乳 氮含量 滴定法 范围 蛋白质含量（计算值） PN-EN ISO 8968-1:2014-03","technique_zh":"滴定法","test_object_zh":"生乳"},{"_id":"6a5e78434cc76d93cba3ad12","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Mleko surowe","test_object_en":"Raw milk","methodology":"Zawartość tłuszczu","methodology_en":"Fat content","parameters":[{"name":"Zakres","range":"(1,50-7,00) %"}],"parameters_en":[{"name":"Range","range":"(1,50-7,00) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość tłuszczu\nZakres (1,50-7,00) %\nMetoda wagowa","reference":"PN-EN ISO 1211:2011","norm_bases":["PN-EN ISO 1211:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mleko surowe Zawartość tłuszczu\nZakres (1,50-7,00) %\nMetoda wagowa PN-EN ISO 1211:2011 Mleko surowe Zawartosc tluszczu\nZakres (1,50-7,00) %\nMetoda wagowa PN-EN ISO 1211:2011","categories":["food"],"row_index":78,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Raw milk Fat content Gravimetric method Range PN-EN ISO 1211:2011","methodology_zh":"脂肪含量","parameters_zh":[{"name":"范围","range":"(1,50-7,00) %"}],"search_zh":"生乳 脂肪含量 重量法 范围 PN-EN ISO 1211:2011","technique_zh":"重量法","test_object_zh":"生乳"},{"_id":"6a5e78434cc76d93cba3ad13","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Surowica krwi bydła, świń, owiec i kóz","test_object_en":"Blood serum of cattle, pigs, sheep and goats","methodology":"Obecność przeciwciał przeciwko, Brucella spp.","methodology_en":"Presence of antibodies against, Brucella spp.","parameters":[],"parameters_en":[],"technique":"Metoda odczynu kwaśnej aglutynacji płytkowej (OKAP)","techniques":["Metoda odczynu kwaśnej aglutynacji płytkowej (OKAP)"],"technique_en":"Acidified plate agglutination test method (OKAP)","computed":[],"computed_en":[],"activity":"Obecność przeciwciał przeciwko, Brucella spp.\nMetoda odczynu kwaśnej aglutynacji płytkowej (OKAP)","reference":"Instrukcja Głównego Lekarza Weterynarii Nr 27/2003 z dnia 25 czerwca 2003 r. Nr GIWz VII.420/lab-4/2003","norm_bases":["Instrukcja Głównego Lekarza Weterynarii Nr 27/2003 z dnia 25 czerwca 2003 r. Nr GIWz VII.420/lab-4/2003"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Surowica krwi bydła, świń, owiec i kóz Obecność przeciwciał przeciwko, Brucella spp.\nMetoda odczynu kwaśnej aglutynacji płytkowej (OKAP) Instrukcja Głównego Lekarza Weterynarii Nr 27/2003 z dnia 25 czerwca 2003 r. Nr GIWz VII.420/lab-4/2003 Surowica krwi bydla, swin, owiec i koz Obecnosc przeciwcial przeciwko, Brucella spp.\nMetoda odczynu kwasnej aglutynacji plytkowej (OKAP) Instrukcja Glownego Lekarza Weterynarii Nr 27/2003 z dnia 25 czerwca 2003 r. Nr GIWz VII.420/lab-4/2003","categories":["other"],"row_index":79,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Blood serum of cattle, pigs, sheep and goats Presence of antibodies against, Brucella spp. Acidified plate agglutination test method (OKAP) Instrukcja Głównego Lekarza Weterynarii Nr 27/2003 z dnia 25 czerwca 2003 r. Nr GIWz VII.420/lab-4/2003","methodology_zh":"针对布鲁氏菌属（Brucella spp.）抗体的检出","search_zh":"针对布鲁氏菌属（Brucella spp.）抗体的检出 Instrukcja Głównego Lekarza Weterynarii Nr 27/2003 z dnia 25 czerwca 2003 r. Nr GIWz VII.420/lab-4/2003"},{"_id":"6a5e78434cc76d93cba3ad14","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Surowica krwi bydła, owiec i kóz","test_object_en":"Blood serum of cattle, sheep and goats","methodology":"Obecność przeciwciał przeciwko, Brucella abortus","methodology_en":"Presence of antibodies against, Brucella abortus","parameters":[],"parameters_en":[],"technique":"Metoda odczynu aglutynacji probówkowej (OA)","techniques":["Metoda odczynu aglutynacji probówkowej (OA)"],"technique_en":"Tube agglutination test (OA)","computed":[],"computed_en":[],"activity":"Obecność przeciwciał przeciwko, Brucella abortus\nMetoda odczynu aglutynacji probówkowej (OA)","reference":"Instrukcja Głównego Lekarza Weterynarii Nr 26/2003 z dnia 25 czerwca 2003 r. Nr GIWzVII.420/lab-3/2003","norm_bases":["Instrukcja Głównego Lekarza Weterynarii Nr 26/2003 z dnia 25 czerwca 2003 r. Nr GIWzVII.420/lab-3/2003"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Surowica krwi bydła, owiec i kóz Obecność przeciwciał przeciwko, Brucella abortus\nMetoda odczynu aglutynacji probówkowej (OA) Instrukcja Głównego Lekarza Weterynarii Nr 26/2003 z dnia 25 czerwca 2003 r. Nr GIWzVII.420/lab-3/2003 Surowica krwi bydla, owiec i koz Obecnosc przeciwcial przeciwko, Brucella abortus\nMetoda odczynu aglutynacji probowkowej (OA) Instrukcja Glownego Lekarza Weterynarii Nr 26/2003 z dnia 25 czerwca 2003 r. Nr GIWzVII.420/lab-3/2003","categories":["other"],"row_index":80,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Blood serum of cattle, sheep and goats Presence of antibodies against, Brucella abortus Tube agglutination test (OA) Instrukcja Głównego Lekarza Weterynarii Nr 26/2003 z dnia 25 czerwca 2003 r. Nr GIWzVII.420/lab-3/2003","search_zh":"流产布鲁氏菌（Brucella abortus）抗体的检出 试管凝集试验法（OA） Instrukcja Głównego Lekarza Weterynarii Nr 26/2003 z dnia 25 czerwca 2003 r. Nr GIWzVII.420/lab-3/2003","technique_zh":"试管凝集试验法（OA）","methodology_zh":"流产布鲁氏菌（Brucella abortus）抗体的检出"},{"_id":"6a5e78434cc76d93cba3ad15","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Surowica krwi koniowatych","test_object_en":"Equine blood serum","methodology":"Obecność przeciwciał przeciwko wirusowi niedokrwistości zakaźnej koni (NZK)","methodology_en":"Presence of antibodies against equine infectious anaemia virus (EIA)","parameters":[],"parameters_en":[],"technique":"Metoda immunodyfuzji w żelu","techniques":["Metoda immunodyfuzji w żelu"],"technique_en":"Gel immunodiffusion method","computed":[],"computed_en":[],"activity":"Obecność przeciwciał przeciwko wirusowi niedokrwistości zakaźnej koni (NZK)\nMetoda immunodyfuzji w żelu","reference":"Instrukcja Głównego Lekarza Weterynarii Nr GIWpr-02010-29/2016 z dnia 07 września 2016 r. | IB-01/Ser_OTS wydanie 03 z 02.09.2024 r. opracowana na podstawie instrukcji producenta testu","norm_bases":["Instrukcja Głównego Lekarza Weterynarii Nr GIWpr-02010-29/2016 z dnia 07 września 2016 r.","IB-01/Ser_OTS wydanie 03 z 02.09.2024 r. opracowana na podstawie instrukcji producenta testu"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Surowica krwi koniowatych Obecność przeciwciał przeciwko wirusowi niedokrwistości zakaźnej koni (NZK)\nMetoda immunodyfuzji w żelu Instrukcja Głównego Lekarza Weterynarii Nr GIWpr-02010-29/2016 z dnia 07 września 2016 r. | IB-01/Ser_OTS wydanie 03 z 02.09.2024 r. opracowana na podstawie instrukcji producenta testu Surowica krwi koniowatych Obecnosc przeciwcial przeciwko wirusowi niedokrwistosci zakaznej koni (NZK)\nMetoda immunodyfuzji w zelu Instrukcja Glownego Lekarza Weterynarii Nr GIWpr-02010-29/2016 z dnia 07 wrzesnia 2016 r. | IB-01/Ser_OTS wydanie 03 z 02.09.2024 r. opracowana na podstawie instrukcji producenta testu","categories":["other"],"row_index":81,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Equine blood serum Presence of antibodies against equine infectious anaemia virus (EIA) Gel immunodiffusion method Instrukcja Głównego Lekarza Weterynarii Nr GIWpr-02010-29/2016 z dnia 07 września 2016 r. | IB-01/Ser_OTS wydanie 03 z 02.09.2024 r. opracowana na podstawie instrukcji producenta testu","search_zh":"马属动物血清 马传染性贫血（NZK）病毒抗体的检出 凝胶免疫扩散法 Instrukcja Głównego Lekarza Weterynarii Nr GIWpr-02010-29/2016 z dnia 07 września 2016 r. | IB-01/Ser_OTS wydanie 03 z 02.09.2024 r. opracowana na podstawie instrukcji producenta testu","test_object_zh":"马属动物血清","methodology_zh":"马传染性贫血（NZK）病毒抗体的检出","technique_zh":"凝胶免疫扩散法"},{"_id":"6a5e78434cc76d93cba3ad16","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Surowica krwi zwierząt 1)","test_object_en":"Animal blood serum 1)","methodology":"Obecność przeciwciał 2)","methodology_en":"Presence of antibodies 2)","parameters":[],"parameters_en":[],"technique":"Metoda immunoenzymatyczna (ELISA)","techniques":["Metoda immunoenzymatyczna (ELISA)"],"technique_en":"Enzyme immunoassay method (ELISA)","computed":[],"computed_en":[],"activity":"Obecność przeciwciał 2)\nMetoda immunoenzymatyczna (ELISA)","reference":"PB-01/Ser_OTS 3) opracowana na podstawie Instrukcji Głównego Lekarza Weterynarii i Instrukcji producentów testów","norm_bases":["PB-01/Ser_OTS 3) opracowana na podstawie Instrukcji Głównego Lekarza Weterynarii i Instrukcji producentów testów"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Surowica krwi zwierząt 1) Obecność przeciwciał 2)\nMetoda immunoenzymatyczna (ELISA) PB-01/Ser_OTS 3) opracowana na podstawie Instrukcji Głównego Lekarza Weterynarii i Instrukcji producentów testów Surowica krwi zwierzat 1) Obecnosc przeciwcial 2)\nMetoda immunoenzymatyczna (ELISA) PB-01/Ser_OTS 3) opracowana na podstawie Instrukcji Glownego Lekarza Weterynarii i Instrukcji producentow testow","categories":["other"],"row_index":82,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Animal blood serum 1) Presence of antibodies 2) Enzyme immunoassay method (ELISA) PB-01/Ser_OTS 3) opracowana na podstawie Instrukcji Głównego Lekarza Weterynarii i Instrukcji producentów testów","search_zh":"动物血清 1) 抗体 2) 的检出 酶联免疫吸附法（ELISA） PB-01/Ser_OTS 3) opracowana na podstawie Instrukcji Głównego Lekarza Weterynarii i Instrukcji producentów testów","technique_zh":"酶联免疫吸附法（ELISA）","methodology_zh":"抗体 2) 的检出","test_object_zh":"动物血清 1)"},{"_id":"6a5e78434cc76d93cba3ad17","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Surowica krwi zwierząt 1)","test_object_en":"Animal blood serum 1)","methodology":"Obecność przeciwciał 2)","methodology_en":"Presence of antibodies 2)","parameters":[],"parameters_en":[],"technique":"Metoda odczynu wiązania dopełniacza (OWD)","techniques":["Metoda odczynu wiązania dopełniacza (OWD)"],"technique_en":"Complement fixation test method (OWD)","computed":[],"computed_en":[],"activity":"Obecność przeciwciał 2)\nMetoda odczynu wiązania dopełniacza (OWD)","reference":"PB-02/Ser_OTS 3) opracowana na podstawie Instrukcji Głównego Lekarza Weterynarii","norm_bases":["PB-02/Ser_OTS 3) opracowana na podstawie Instrukcji Głównego Lekarza Weterynarii"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Surowica krwi zwierząt 1) Obecność przeciwciał 2)\nMetoda odczynu wiązania dopełniacza (OWD) PB-02/Ser_OTS 3) opracowana na podstawie Instrukcji Głównego Lekarza Weterynarii Surowica krwi zwierzat 1) Obecnosc przeciwcial 2)\nMetoda odczynu wiazania dopelniacza (OWD) PB-02/Ser_OTS 3) opracowana na podstawie Instrukcji Glownego Lekarza Weterynarii","categories":["other"],"row_index":83,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Animal blood serum 1) Presence of antibodies 2) Complement fixation test method (OWD) PB-02/Ser_OTS 3) opracowana na podstawie Instrukcji Głównego Lekarza Weterynarii","search_zh":"动物血清 1) 抗体 2) 的检出 补体结合试验法（OWD） PB-02/Ser_OTS 3) opracowana na podstawie Instrukcji Głównego Lekarza Weterynarii","technique_zh":"补体结合试验法（OWD）","methodology_zh":"抗体 2) 的检出","test_object_zh":"动物血清 1)"},{"_id":"6a5e78434cc76d93cba3ad18","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Materiał biologiczny 1)","test_object_en":"Biological material 1)","methodology":"Obecność materiału genetycznego 2)","methodology_en":"Presence of genetic material 2)","parameters":[],"parameters_en":[],"technique":"Metoda Real Time PCR","techniques":["Metoda Real Time PCR"],"technique_en":"Real Time PCR method","computed":[],"computed_en":[],"activity":"Obecność materiału genetycznego 2)\nMetoda Real Time PCR","reference":"Instrukcja Głównego Lekarza Weterynarii 4) | PB-03/Ser_OTS 3) opracowana na podstawie instrukcji producentów testów diagnostycznych","norm_bases":["Instrukcja Głównego Lekarza Weterynarii 4)","PB-03/Ser_OTS 3) opracowana na podstawie instrukcji producentów testów diagnostycznych"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiał biologiczny 1) Obecność materiału genetycznego 2)\nMetoda Real Time PCR Instrukcja Głównego Lekarza Weterynarii 4) | PB-03/Ser_OTS 3) opracowana na podstawie instrukcji producentów testów diagnostycznych Material biologiczny 1) Obecnosc materialu genetycznego 2)\nMetoda Real Time PCR Instrukcja Glownego Lekarza Weterynarii 4) | PB-03/Ser_OTS 3) opracowana na podstawie instrukcji producentow testow diagnostycznych","categories":["materials"],"row_index":84,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Biological material 1) Presence of genetic material 2) Real Time PCR method Instrukcja Głównego Lekarza Weterynarii 4) | PB-03/Ser_OTS 3) opracowana na podstawie instrukcji producentów testów diagnostycznych","search_zh":"实时荧光 PCR 法 Instrukcja Głównego Lekarza Weterynarii 4) | PB-03/Ser_OTS 3) opracowana na podstawie instrukcji producentów testów diagnostycznych","technique_zh":"实时荧光 PCR 法"},{"_id":"6a5e78434cc76d93cba3ad19","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Pień mózgu przeżuwaczy 1)","test_object_en":"Ruminant brain stem 1)","methodology":"Obecność patologicznego białka prionowego","methodology_en":"Presence of pathological prion protein","parameters":[],"parameters_en":[],"technique":"Metoda immunoenzymatyczna (ELISA)","techniques":["Metoda immunoenzymatyczna (ELISA)"],"technique_en":"Enzyme immunoassay method (ELISA)","computed":[],"computed_en":[],"activity":"Obecność patologicznego białka prionowego\nMetoda immunoenzymatyczna (ELISA)","reference":"PB-01/TSE_OTS 2) opracowana na podstawie Instrukcji Głównego Lekarza Weterynarii i instrukcji producentów testów","norm_bases":["PB-01/TSE_OTS 2) opracowana na podstawie Instrukcji Głównego Lekarza Weterynarii i instrukcji producentów testów"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pień mózgu przeżuwaczy 1) Obecność patologicznego białka prionowego\nMetoda immunoenzymatyczna (ELISA) PB-01/TSE_OTS 2) opracowana na podstawie Instrukcji Głównego Lekarza Weterynarii i instrukcji producentów testów Pien mozgu przezuwaczy 1) Obecnosc patologicznego bialka prionowego\nMetoda immunoenzymatyczna (ELISA) PB-01/TSE_OTS 2) opracowana na podstawie Instrukcji Glownego Lekarza Weterynarii i instrukcji producentow testow","categories":["other"],"row_index":85,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Ruminant brain stem 1) Presence of pathological prion protein Enzyme immunoassay method (ELISA) PB-01/TSE_OTS 2) opracowana na podstawie Instrukcji Głównego Lekarza Weterynarii i instrukcji producentów testów","search_zh":"酶联免疫吸附法（ELISA） PB-01/TSE_OTS 2) opracowana na podstawie Instrukcji Głównego Lekarza Weterynarii i instrukcji producentów testów","technique_zh":"酶联免疫吸附法（ELISA）"},{"_id":"6a5e78434cc76d93cba3ad1a","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Mięso surowe świń i dzików","test_object_en":"Raw meat of pigs and wild boars","methodology":"Obecność włośni (Trichinella) metoda wytrawiania próbki zbiorczej z zastosowaniem metody magnetycznego mieszania","methodology_en":"Presence of trichinae (Trichinella) magnetic stirring method of digestion of a pooled sample","parameters":[],"parameters_en":[],"technique":"Metoda referencyjna","techniques":["Metoda referencyjna"],"technique_en":"Reference method","computed":[],"computed_en":[],"activity":"Obecność włośni (Trichinella) metoda wytrawiania próbki zbiorczej z zastosowaniem metody magnetycznego mieszania\nMetoda referencyjna","reference":"PN-EN ISO 187431) | Instrukcja Głównego Lekarza Weterynarii 2)","norm_bases":["PN-EN ISO 187431)","Instrukcja Głównego Lekarza Weterynarii 2)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mięso surowe świń i dzików Obecność włośni (Trichinella) metoda wytrawiania próbki zbiorczej z zastosowaniem metody magnetycznego mieszania\nMetoda referencyjna PN-EN ISO 187431) | Instrukcja Głównego Lekarza Weterynarii 2) Mieso surowe swin i dzikow Obecnosc wlosni (Trichinella) metoda wytrawiania probki zbiorczej z zastosowaniem metody magnetycznego mieszania\nMetoda referencyjna PN-EN ISO 187431) | Instrukcja Glownego Lekarza Weterynarii 2)","categories":["food"],"row_index":86,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Raw meat of pigs and wild boars Presence of trichinae (Trichinella) magnetic stirring method of digestion of a pooled sample Reference method PN-EN ISO 187431) | Instrukcja Głównego Lekarza Weterynarii 2)","search_zh":"猪和野猪生肉 旋毛虫（Trichinella）的检出 混合样品磁力搅拌消化法 基准方法 PN-EN ISO 187431) | Instrukcja Głównego Lekarza Weterynarii 2)","technique_zh":"基准方法","test_object_zh":"猪和野猪生肉","methodology_zh":"旋毛虫（Trichinella）的检出 混合样品磁力搅拌消化法"},{"_id":"6a5e78434cc76d93cba3ad1b","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Mięso surowe świń i dzików","test_object_en":"Raw meat of pigs and wild boars","methodology":"Obecność włośni (Trichinella) metoda wytrawiania próbki zbiorczej z zastosowaniem metody magnetycznego mieszania","methodology_en":"Presence of trichinae (Trichinella) magnetic stirring method of digestion of a pooled sample","parameters":[],"parameters_en":[],"technique":"Metoda referencyjna","techniques":["Metoda referencyjna"],"technique_en":"Reference method","computed":[],"computed_en":[],"activity":"Obecność włośni (Trichinella) metoda wytrawiania próbki zbiorczej z zastosowaniem metody magnetycznego mieszania\nMetoda referencyjna","reference":"PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2)","norm_bases":["PN-EN ISO 18743 1)","Instrukcja Głównego Lekarza Weterynarii 2)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mięso surowe świń i dzików Obecność włośni (Trichinella) metoda wytrawiania próbki zbiorczej z zastosowaniem metody magnetycznego mieszania\nMetoda referencyjna PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2) Mieso surowe swin i dzikow Obecnosc wlosni (Trichinella) metoda wytrawiania probki zbiorczej z zastosowaniem metody magnetycznego mieszania\nMetoda referencyjna PN-EN ISO 18743 1) | Instrukcja Glownego Lekarza Weterynarii 2)","categories":["food"],"row_index":87,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Raw meat of pigs and wild boars Presence of trichinae (Trichinella) magnetic stirring method of digestion of a pooled sample Reference method PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2)","search_zh":"猪和野猪生肉 旋毛虫（Trichinella）的检出 混合样品磁力搅拌消化法 基准方法 PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2)","technique_zh":"基准方法","test_object_zh":"猪和野猪生肉","methodology_zh":"旋毛虫（Trichinella）的检出 混合样品磁力搅拌消化法"},{"_id":"6a5e78434cc76d93cba3ad1c","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Mięso surowe świń i dzików","test_object_en":"Raw meat of pigs and wild boars","methodology":"Obecność włośni (Trichinella) metoda wytrawiania próbki zbiorczej z zastosowaniem metody magnetycznego mieszania","methodology_en":"Presence of trichinae (Trichinella) magnetic stirring method of digestion of a pooled sample","parameters":[],"parameters_en":[],"technique":"Metoda referencyjna","techniques":["Metoda referencyjna"],"technique_en":"Reference method","computed":[],"computed_en":[],"activity":"Obecność włośni (Trichinella) metoda wytrawiania próbki zbiorczej z zastosowaniem metody magnetycznego mieszania\nMetoda referencyjna","reference":"PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2)","norm_bases":["PN-EN ISO 18743 1)","Instrukcja Głównego Lekarza Weterynarii 2)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mięso surowe świń i dzików Obecność włośni (Trichinella) metoda wytrawiania próbki zbiorczej z zastosowaniem metody magnetycznego mieszania\nMetoda referencyjna PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2) Mieso surowe swin i dzikow Obecnosc wlosni (Trichinella) metoda wytrawiania probki zbiorczej z zastosowaniem metody magnetycznego mieszania\nMetoda referencyjna PN-EN ISO 18743 1) | Instrukcja Glownego Lekarza Weterynarii 2)","categories":["food"],"row_index":88,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Raw meat of pigs and wild boars Presence of trichinae (Trichinella) magnetic stirring method of digestion of a pooled sample Reference method PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2)","search_zh":"猪和野猪生肉 旋毛虫（Trichinella）的检出 混合样品磁力搅拌消化法 基准方法 PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2)","technique_zh":"基准方法","test_object_zh":"猪和野猪生肉","methodology_zh":"旋毛虫（Trichinella）的检出 混合样品磁力搅拌消化法"},{"_id":"6a5e78434cc76d93cba3ad1d","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Mięso surowe świń i dzików","test_object_en":"Raw meat of pigs and wild boars","methodology":"Obecność włośni (Trichinella) metoda wytrawiania próbki zbiorczej z zastosowaniem metody magnetycznego mieszania","methodology_en":"Presence of trichinae (Trichinella) magnetic stirring method of digestion of a pooled sample","parameters":[],"parameters_en":[],"technique":"Metoda referencyjna","techniques":["Metoda referencyjna"],"technique_en":"Reference method","computed":[],"computed_en":[],"activity":"Obecność włośni (Trichinella) metoda wytrawiania próbki zbiorczej z zastosowaniem metody magnetycznego mieszania\nMetoda referencyjna","reference":"PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2)","norm_bases":["PN-EN ISO 18743 1)","Instrukcja Głównego Lekarza Weterynarii 2)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mięso surowe świń i dzików Obecność włośni (Trichinella) metoda wytrawiania próbki zbiorczej z zastosowaniem metody magnetycznego mieszania\nMetoda referencyjna PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2) Mieso surowe swin i dzikow Obecnosc wlosni (Trichinella) metoda wytrawiania probki zbiorczej z zastosowaniem metody magnetycznego mieszania\nMetoda referencyjna PN-EN ISO 18743 1) | Instrukcja Glownego Lekarza Weterynarii 2)","categories":["food"],"row_index":89,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Raw meat of pigs and wild boars Presence of trichinae (Trichinella) magnetic stirring method of digestion of a pooled sample Reference method PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2)","search_zh":"猪和野猪生肉 旋毛虫（Trichinella）的检出 混合样品磁力搅拌消化法 基准方法 PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2)","technique_zh":"基准方法","test_object_zh":"猪和野猪生肉","methodology_zh":"旋毛虫（Trichinella）的检出 混合样品磁力搅拌消化法"},{"_id":"6a5e78434cc76d93cba3ad1e","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Mięso surowe świń i dzików","test_object_en":"Raw meat of pigs and wild boars","methodology":"Obecność włośni (Trichinella) metoda wytrawiania próbki zbiorczej z zastosowaniem metody magnetycznego mieszania","methodology_en":"Presence of trichinae (Trichinella) magnetic stirring method of digestion of a pooled sample","parameters":[],"parameters_en":[],"technique":"Metoda referencyjna","techniques":["Metoda referencyjna"],"technique_en":"Reference method","computed":[],"computed_en":[],"activity":"Obecność włośni (Trichinella) metoda wytrawiania próbki zbiorczej z zastosowaniem metody magnetycznego mieszania\nMetoda referencyjna","reference":"PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2)","norm_bases":["PN-EN ISO 18743 1)","Instrukcja Głównego Lekarza Weterynarii 2)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mięso surowe świń i dzików Obecność włośni (Trichinella) metoda wytrawiania próbki zbiorczej z zastosowaniem metody magnetycznego mieszania\nMetoda referencyjna PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2) Mieso surowe swin i dzikow Obecnosc wlosni (Trichinella) metoda wytrawiania probki zbiorczej z zastosowaniem metody magnetycznego mieszania\nMetoda referencyjna PN-EN ISO 18743 1) | Instrukcja Glownego Lekarza Weterynarii 2)","categories":["food"],"row_index":90,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Raw meat of pigs and wild boars Presence of trichinae (Trichinella) magnetic stirring method of digestion of a pooled sample Reference method PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2)","search_zh":"猪和野猪生肉 旋毛虫（Trichinella）的检出 混合样品磁力搅拌消化法 基准方法 PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2)","technique_zh":"基准方法","test_object_zh":"猪和野猪生肉","methodology_zh":"旋毛虫（Trichinella）的检出 混合样品磁力搅拌消化法"},{"_id":"6a5e78434cc76d93cba3ad1f","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Mięso surowe świń i dzików","test_object_en":"Raw meat of pigs and wild boars","methodology":"Obecność włośni (Trichinella) metoda wytrawiania próbki zbiorczej z zastosowaniem metody magnetycznego mieszania","methodology_en":"Presence of trichinae (Trichinella) magnetic stirring method of digestion of a pooled sample","parameters":[],"parameters_en":[],"technique":"Metoda referencyjna","techniques":["Metoda referencyjna"],"technique_en":"Reference method","computed":[],"computed_en":[],"activity":"Obecność włośni (Trichinella) metoda wytrawiania próbki zbiorczej z zastosowaniem metody magnetycznego mieszania\nMetoda referencyjna","reference":"PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2)","norm_bases":["PN-EN ISO 18743 1)","Instrukcja Głównego Lekarza Weterynarii 2)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mięso surowe świń i dzików Obecność włośni (Trichinella) metoda wytrawiania próbki zbiorczej z zastosowaniem metody magnetycznego mieszania\nMetoda referencyjna PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2) Mieso surowe swin i dzikow Obecnosc wlosni (Trichinella) metoda wytrawiania probki zbiorczej z zastosowaniem metody magnetycznego mieszania\nMetoda referencyjna PN-EN ISO 18743 1) | Instrukcja Glownego Lekarza Weterynarii 2)","categories":["food"],"row_index":91,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Raw meat of pigs and wild boars Presence of trichinae (Trichinella) magnetic stirring method of digestion of a pooled sample Reference method PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2)","search_zh":"猪和野猪生肉 旋毛虫（Trichinella）的检出 混合样品磁力搅拌消化法 基准方法 PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2)","technique_zh":"基准方法","test_object_zh":"猪和野猪生肉","methodology_zh":"旋毛虫（Trichinella）的检出 混合样品磁力搅拌消化法"},{"_id":"6a5e78434cc76d93cba3ad20","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Mięso surowe świń i dzików","test_object_en":"Raw meat of pigs and wild boars","methodology":"Obecność włośni (Trichinella) metoda wytrawiania próbki zbiorczej z zastosowaniem metody magnetycznego mieszania","methodology_en":"Presence of trichinae (Trichinella) magnetic stirring method of digestion of a pooled sample","parameters":[],"parameters_en":[],"technique":"Metoda referencyjna","techniques":["Metoda referencyjna"],"technique_en":"Reference method","computed":[],"computed_en":[],"activity":"Obecność włośni (Trichinella) metoda wytrawiania próbki zbiorczej z zastosowaniem metody magnetycznego mieszania\nMetoda referencyjna","reference":"PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2)","norm_bases":["PN-EN ISO 18743 1)","Instrukcja Głównego Lekarza Weterynarii 2)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mięso surowe świń i dzików Obecność włośni (Trichinella) metoda wytrawiania próbki zbiorczej z zastosowaniem metody magnetycznego mieszania\nMetoda referencyjna PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2) Mieso surowe swin i dzikow Obecnosc wlosni (Trichinella) metoda wytrawiania probki zbiorczej z zastosowaniem metody magnetycznego mieszania\nMetoda referencyjna PN-EN ISO 18743 1) | Instrukcja Glownego Lekarza Weterynarii 2)","categories":["food"],"row_index":92,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Raw meat of pigs and wild boars Presence of trichinae (Trichinella) magnetic stirring method of digestion of a pooled sample Reference method PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2)","search_zh":"猪和野猪生肉 旋毛虫（Trichinella）的检出 混合样品磁力搅拌消化法 基准方法 PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2)","technique_zh":"基准方法","test_object_zh":"猪和野猪生肉","methodology_zh":"旋毛虫（Trichinella）的检出 混合样品磁力搅拌消化法"},{"_id":"6a5e78434cc76d93cba3ad21","lab_id":"69ad52a3de79e566650fb30c","country":"PL","accr_number":"AB 598","accr_body":"PCA","test_object":"Mięso surowe świń i dzików","test_object_en":"Raw meat of pigs and wild boars","methodology":"Obecność włośni (Trichinella) metoda wytrawiania próbki zbiorczej z zastosowaniem metody magnetycznego mieszania","methodology_en":"Presence of trichinae (Trichinella) magnetic stirring method of digestion of a pooled sample","parameters":[],"parameters_en":[],"technique":"Metoda referencyjna","techniques":["Metoda referencyjna"],"technique_en":"Reference method","computed":[],"computed_en":[],"activity":"Obecność włośni (Trichinella) metoda wytrawiania próbki zbiorczej z zastosowaniem metody magnetycznego mieszania\nMetoda referencyjna","reference":"PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2)","norm_bases":["PN-EN ISO 18743 1)","Instrukcja Głównego Lekarza Weterynarii 2)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mięso surowe świń i dzików Obecność włośni (Trichinella) metoda wytrawiania próbki zbiorczej z zastosowaniem metody magnetycznego mieszania\nMetoda referencyjna PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2) Mieso surowe swin i dzikow Obecnosc wlosni (Trichinella) metoda wytrawiania probki zbiorczej z zastosowaniem metody magnetycznego mieszania\nMetoda referencyjna PN-EN ISO 18743 1) | Instrukcja Glownego Lekarza Weterynarii 2)","categories":["food"],"row_index":93,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Raw meat of pigs and wild boars Presence of trichinae (Trichinella) magnetic stirring method of digestion of a pooled sample Reference method PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2)","search_zh":"猪和野猪生肉 旋毛虫（Trichinella）的检出 混合样品磁力搅拌消化法 基准方法 PN-EN ISO 18743 1) | Instrukcja Głównego Lekarza Weterynarii 2)","technique_zh":"基准方法","test_object_zh":"猪和野猪生肉","methodology_zh":"旋毛虫（Trichinella）的检出 混合样品磁力搅拌消化法"}],"has_pdf":true}