{"lab":{"_id":"69ad52a3de79e566650fb2ee","accr_number":"AB 580","country":"PL","accr_body":"PCA","address":"PRACOWNIA DIAGNOSTYKI I NAPRAW MOSTÓW, ul. Instytutowa 1, 03-302 Warszawa","categories":["construction","water"],"city":"Warszawa","imported_at":"2026-03-08T10:42:43.265Z","methods_count":18,"name":"INSTYTUT BADAWCZY DRÓG I MOSTÓW","parse_status":"parsed","parse_version":2,"pdf_files":["AB_580.pdf"],"scope_summary":"","search_text":"instytut badawczy dróg i mostów pracownia diagnostyki i napraw mostów, ul. instytutowa 1, 03-302 warszawa construction other metrology water","status":"active","updated_at":"2026-03-08T14:51:27.895Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:27.895Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20580,podmiot.html","fields_of_testing":[{"codes":"J/5","pl":"Badania mechaniczne materiałów i konstrukcji budowlanych","en":"Mechanical tests of building materials and building items"},{"codes":"N/5","pl":"Badania właściwości fizycznych materiałów budowlanych","en":"Tests of physical properties of building materials"}],"issue":{"no":"17","date":"30.01.2025"},"parse_date":"2026-07-20T07:09:43.768Z","parse_source":"script-pdfplumber","map_coord":[52.267295,21.025067],"map_geo":"nominatim-street","has_en":true,"category_counts":{"other":9,"construction":8,"water":1},"category_scores":{"other":4.5,"construction":3.56,"water":0.06},"has_zh":true},"methods":[{"_id":"6a5dc9b7f1c10c8ce825d21d","lab_id":"69ad52a3de79e566650fb2ee","country":"PL","accr_number":"AB 580","accr_body":"PCA","test_object":"Izolacje przeciwwodne","test_object_en":"Waterproofing","methodology":"Wygląd zewnętrzny","methodology_en":"External appearance","parameters":[],"parameters_en":[],"technique":"Metoda: ocena wizualna","techniques":["Metoda: ocena wizualna"],"technique_en":"Method: visual assessment","computed":[],"computed_en":[],"activity":"Wygląd zewnętrzny\nMetoda: ocena wizualna","reference":"PN-90/B-04615 p. 2.3","norm_bases":["PN-90/B-04615 p. 2.3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Izolacje przeciwwodne Wygląd zewnętrzny\nMetoda: ocena wizualna PN-90/B-04615 p. 2.3 Izolacje przeciwwodne Wyglad zewnetrzny\nMetoda: ocena wizualna PN-90/B-04615 p. 2.3","categories":["construction"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waterproofing External appearance Method: visual assessment PN-90/B-04615 p. 2.3","methodology_zh":"外观","search_zh":"防水隔离层 外观 方法：目视评定 PN-90/B-04615 p. 2.3","test_object_zh":"防水隔离层","technique_zh":"方法：目视评定"},{"_id":"6a5dc9b7f1c10c8ce825d21e","lab_id":"69ad52a3de79e566650fb2ee","country":"PL","accr_number":"AB 580","accr_body":"PCA","test_object":"Izolacje przeciwwodne","test_object_en":"Waterproofing","methodology":"Wymiary arkusza","methodology_en":"Sheet dimensions","parameters":[{"name":"długość","range":"(0 - 20) m"},{"name":"szerokość","range":"(0 - 1,5) m"}],"parameters_en":[{"name":"length","range":"(0 - 20) m"},{"name":"width","range":"(0 - 1,5) m"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Wymiary arkusza\nZakres:\ndługość (0 - 20) m\nszerokość (0 - 1,5) m\nMetoda: pomiar bezpośredni","reference":"PN-90/B-04615 p. 2.4","norm_bases":["PN-90/B-04615 p. 2.4"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Izolacje przeciwwodne Wymiary arkusza\nZakres:\ndługość (0 - 20) m\nszerokość (0 - 1,5) m\nMetoda: pomiar bezpośredni PN-90/B-04615 p. 2.4 Izolacje przeciwwodne Wymiary arkusza\nZakres:\ndlugosc (0 - 20) m\nszerokosc (0 - 1,5) m\nMetoda: pomiar bezposredni PN-90/B-04615 p. 2.4","categories":["construction"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waterproofing Sheet dimensions Method: direct measurement length width PN-90/B-04615 p. 2.4","search_zh":"防水隔离层 方法：直接测量 长度 宽度 PN-90/B-04615 p. 2.4","technique_zh":"方法：直接测量","test_object_zh":"防水隔离层","parameters_zh":[{"name":"长度","range":"(0 - 20) m"},{"name":"宽度","range":"(0 - 1,5) m"}]},{"_id":"6a5dc9b7f1c10c8ce825d21f","lab_id":"69ad52a3de79e566650fb2ee","country":"PL","accr_number":"AB 580","accr_body":"PCA","test_object":"Izolacje przeciwwodne","test_object_en":"Waterproofing","methodology":"Przyczepność izolacji do podłoża","methodology_en":"Adhesion of the insulation to the substrate","parameters":[{"name":"Zakres","range":"(0 - 8) MPa"}],"parameters_en":[{"name":"Range","range":"(0 - 8) MPa"}],"technique":"Metoda: „pull-off” − pomiar przez odrywanie","techniques":["Metoda: „pull-off” − pomiar przez odrywanie"],"technique_en":"Method: „pull-off” − measurement by pulling off","computed":[],"computed_en":[],"activity":"Przyczepność izolacji do podłoża\nZakres (0 - 8) MPa\nMetoda: „pull-off” − pomiar przez odrywanie","reference":"PB/TM-1/5:2024 wydanie 5 z dnia 26.11.2024 r.","norm_bases":["PB/TM-1/5:2024 wydanie 5 z dnia 26.11.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Izolacje przeciwwodne Przyczepność izolacji do podłoża\nZakres (0 - 8) MPa\nMetoda: „pull-off” − pomiar przez odrywanie PB/TM-1/5:2024 wydanie 5 z dnia 26.11.2024 r. Izolacje przeciwwodne Przyczepnosc izolacji do podloza\nZakres (0 - 8) MPa\nMetoda: „pull-off” − pomiar przez odrywanie PB/TM-1/5:2024 wydanie 5 z dnia 26.11.2024 r.","categories":["construction"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waterproofing Adhesion of the insulation to the substrate Method: „pull-off” − measurement by pulling off Range PB/TM-1/5:2024 wydanie 5 z dnia 26.11.2024 r.","parameters_zh":[{"name":"范围","range":"(0 - 8) MPa"}],"search_zh":"防水隔离层 范围 PB/TM-1/5:2024 wydanie 5 z dnia 26.11.2024 r.","test_object_zh":"防水隔离层"},{"_id":"6a5dc9b7f1c10c8ce825d220","lab_id":"69ad52a3de79e566650fb2ee","country":"PL","accr_number":"AB 580","accr_body":"PCA","test_object":"Izolacje przeciwwodne","test_object_en":"Waterproofing","methodology":"Grubość arkusza","methodology_en":"Sheet thickness","parameters":[{"name":"Zakres","range":"(0 - 150) mm"}],"parameters_en":[{"name":"Range","range":"(0 - 150) mm"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Grubość arkusza\nZakres (0 - 150) mm\nMetoda: pomiar bezpośredni","reference":"PB/TM-1/1:2024 wydanie 4 z dnia 26.11.2024 r.","norm_bases":["PB/TM-1/1:2024 wydanie 4 z dnia 26.11.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Izolacje przeciwwodne Grubość arkusza\nZakres (0 - 150) mm\nMetoda: pomiar bezpośredni PB/TM-1/1:2024 wydanie 4 z dnia 26.11.2024 r. Izolacje przeciwwodne Grubosc arkusza\nZakres (0 - 150) mm\nMetoda: pomiar bezposredni PB/TM-1/1:2024 wydanie 4 z dnia 26.11.2024 r.","categories":["construction"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waterproofing Sheet thickness Method: direct measurement Range PB/TM-1/1:2024 wydanie 4 z dnia 26.11.2024 r.","parameters_zh":[{"name":"范围","range":"(0 - 150) mm"}],"search_zh":"防水隔离层 方法：直接测量 范围 PB/TM-1/1:2024 wydanie 4 z dnia 26.11.2024 r.","technique_zh":"方法：直接测量","test_object_zh":"防水隔离层"},{"_id":"6a5dc9b7f1c10c8ce825d221","lab_id":"69ad52a3de79e566650fb2ee","country":"PL","accr_number":"AB 580","accr_body":"PCA","test_object":"Izolacje przeciwwodne","test_object_en":"Waterproofing","methodology":"Grubość warstwy izolacyjnej pod osnową","methodology_en":"Thickness of the insulating layer under the carrier","parameters":[{"name":"Zakres","range":"(0 - 150) mm"}],"parameters_en":[{"name":"Range","range":"(0 - 150) mm"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Grubość warstwy izolacyjnej pod osnową\nZakres (0 - 150) mm\nMetoda: pomiar bezpośredni","reference":"PB/TM-1/2:2024 wydanie 4 z dnia 26.11.2024 r.","norm_bases":["PB/TM-1/2:2024 wydanie 4 z dnia 26.11.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Izolacje przeciwwodne Grubość warstwy izolacyjnej pod osnową\nZakres (0 - 150) mm\nMetoda: pomiar bezpośredni PB/TM-1/2:2024 wydanie 4 z dnia 26.11.2024 r. Izolacje przeciwwodne Grubosc warstwy izolacyjnej pod osnowa\nZakres (0 - 150) mm\nMetoda: pomiar bezposredni PB/TM-1/2:2024 wydanie 4 z dnia 26.11.2024 r.","categories":["construction"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waterproofing Thickness of the insulating layer under the carrier Method: direct measurement Range PB/TM-1/2:2024 wydanie 4 z dnia 26.11.2024 r.","parameters_zh":[{"name":"范围","range":"(0 - 150) mm"}],"search_zh":"防水隔离层 方法：直接测量 范围 PB/TM-1/2:2024 wydanie 4 z dnia 26.11.2024 r.","technique_zh":"方法：直接测量","test_object_zh":"防水隔离层"},{"_id":"6a5dc9b7f1c10c8ce825d222","lab_id":"69ad52a3de79e566650fb2ee","country":"PL","accr_number":"AB 580","accr_body":"PCA","test_object":"Izolacje przeciwwodne","test_object_en":"Waterproofing","methodology":"Odporność na podwyższoną temperaturę","methodology_en":"Resistance to elevated temperature","parameters":[{"name":"Zakres","range":"(100 - 150) °C"}],"parameters_en":[{"name":"Range","range":"(100 - 150) °C"}],"technique":"Metoda: ocena wizualna","techniques":["Metoda: ocena wizualna"],"technique_en":"Method: visual assessment","computed":[],"computed_en":[],"activity":"Odporność na podwyższoną temperaturę\nZakres (100 - 150) °C\nMetoda: ocena wizualna","reference":"PN-90/B-04615 p. 2.2 i 2.11","norm_bases":["PN-90/B-04615 p. 2.2 i 2.11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Izolacje przeciwwodne Odporność na podwyższoną temperaturę\nZakres (100 - 150) °C\nMetoda: ocena wizualna PN-90/B-04615 p. 2.2 i 2.11 Izolacje przeciwwodne Odpornosc na podwyzszona temperature\nZakres (100 - 150) °C\nMetoda: ocena wizualna PN-90/B-04615 p. 2.2 i 2.11","categories":["construction"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waterproofing Resistance to elevated temperature Method: visual assessment Range PN-90/B-04615 p. 2.2 i 2.11","parameters_zh":[{"name":"范围","range":"(100 - 150) °C"}],"search_zh":"防水隔离层 方法：目视评定 范围 PN-90/B-04615 p. 2.2 i 2.11","test_object_zh":"防水隔离层","technique_zh":"方法：目视评定"},{"_id":"6a5dc9b7f1c10c8ce825d223","lab_id":"69ad52a3de79e566650fb2ee","country":"PL","accr_number":"AB 580","accr_body":"PCA","test_object":"Izolacje przeciwwodne","test_object_en":"Waterproofing","methodology":"Nasiąkliwość","methodology_en":"Water absorption","parameters":[{"name":"Zakres","range":"(0 - 10) %"}],"parameters_en":[{"name":"Range","range":"(0 - 10) %"}],"technique":"Metoda: pomiar masy","techniques":["Metoda: pomiar masy"],"technique_en":"Method: mass measurement","computed":[],"computed_en":[],"activity":"Nasiąkliwość\nZakres (0 - 10) %\nMetoda: pomiar masy","reference":"PN-90/B-04615 p. 2.2 i 2.10","norm_bases":["PN-90/B-04615 p. 2.2 i 2.10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Izolacje przeciwwodne Nasiąkliwość\nZakres (0 - 10) %\nMetoda: pomiar masy PN-90/B-04615 p. 2.2 i 2.10 Izolacje przeciwwodne Nasiakliwosc\nZakres (0 - 10) %\nMetoda: pomiar masy PN-90/B-04615 p. 2.2 i 2.10","categories":["construction"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waterproofing Water absorption Method: mass measurement Range PN-90/B-04615 p. 2.2 i 2.10","methodology_zh":"吸水率","parameters_zh":[{"name":"范围","range":"(0 - 10) %"}],"search_zh":"防水隔离层 吸水率 范围 PN-90/B-04615 p. 2.2 i 2.10","test_object_zh":"防水隔离层"},{"_id":"6a5dc9b7f1c10c8ce825d224","lab_id":"69ad52a3de79e566650fb2ee","country":"PL","accr_number":"AB 580","accr_body":"PCA","test_object":"Roztwory asfaltowe","test_object_en":"Bituminous solutions","methodology":"Wygląd zewnętrzny i konsystencja robocza","methodology_en":"External appearance and working consistency","parameters":[],"parameters_en":[],"technique":"Metoda: ocena wizualna","techniques":["Metoda: ocena wizualna"],"technique_en":"Method: visual assessment","computed":[],"computed_en":[],"activity":"Wygląd zewnętrzny i konsystencja robocza\nMetoda: ocena wizualna","reference":"PN-B-24620:1998 p. 2.2.2 i 2.5.1 | PN-B-24620:1998/Az1:2004","norm_bases":["PN-B-24620:1998 p. 2.2.2 i 2.5.1","PN-B-24620:1998/Az1:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Roztwory asfaltowe Wygląd zewnętrzny i konsystencja robocza\nMetoda: ocena wizualna PN-B-24620:1998 p. 2.2.2 i 2.5.1 | PN-B-24620:1998/Az1:2004 Roztwory asfaltowe Wyglad zewnetrzny i konsystencja robocza\nMetoda: ocena wizualna PN-B-24620:1998 p. 2.2.2 i 2.5.1 | PN-B-24620:1998/Az1:2004","categories":["other"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Bituminous solutions External appearance and working consistency Method: visual assessment PN-B-24620:1998 p. 2.2.2 i 2.5.1 | PN-B-24620:1998/Az1:2004","search_zh":"方法：目视评定 PN-B-24620:1998 p. 2.2.2 i 2.5.1 | PN-B-24620:1998/Az1:2004","technique_zh":"方法：目视评定"},{"_id":"6a5dc9b7f1c10c8ce825d225","lab_id":"69ad52a3de79e566650fb2ee","country":"PL","accr_number":"AB 580","accr_body":"PCA","test_object":"Roztwory asfaltowe","test_object_en":"Bituminous solutions","methodology":"Czas wysychania","methodology_en":"Drying time","parameters":[],"parameters_en":[],"technique":"Metoda: ocena wizualna","techniques":["Metoda: ocena wizualna"],"technique_en":"Method: visual assessment","computed":[],"computed_en":[],"activity":"Czas wysychania\nMetoda: ocena wizualna","reference":"PB-TM-1/10:2024 wydanie 6 z dnia 26.11.2024 r.","norm_bases":["PB-TM-1/10:2024 wydanie 6 z dnia 26.11.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Roztwory asfaltowe Czas wysychania\nMetoda: ocena wizualna PB-TM-1/10:2024 wydanie 6 z dnia 26.11.2024 r. Roztwory asfaltowe Czas wysychania\nMetoda: ocena wizualna PB-TM-1/10:2024 wydanie 6 z dnia 26.11.2024 r.","categories":["other"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Bituminous solutions Drying time Method: visual assessment PB-TM-1/10:2024 wydanie 6 z dnia 26.11.2024 r.","search_zh":"方法：目视评定 PB-TM-1/10:2024 wydanie 6 z dnia 26.11.2024 r.","technique_zh":"方法：目视评定"},{"_id":"6a5dc9b7f1c10c8ce825d226","lab_id":"69ad52a3de79e566650fb2ee","country":"PL","accr_number":"AB 580","accr_body":"PCA","test_object":"Zaprawy naprawcze i powłoki","test_object_en":"Repair mortars and coatings","methodology":"Przyczepność do podłoża","methodology_en":"Adhesion to the substrate","parameters":[{"name":"Zakres","range":"(0 - 8) MPa"}],"parameters_en":[{"name":"Range","range":"(0 - 8) MPa"}],"technique":"Metoda „pull-off” − pomiar przez odrywanie","techniques":["Metoda „pull-off” − pomiar przez odrywanie"],"technique_en":"„Pull-off” method − pull-off measurement","computed":[],"computed_en":[],"activity":"Przyczepność do podłoża\nZakres (0 - 8) MPa\nMetoda „pull-off” − pomiar przez odrywanie","reference":"PB/TM-1/6:2024 wydanie 5 z dnia 26.11.2024 r.","norm_bases":["PB/TM-1/6:2024 wydanie 5 z dnia 26.11.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zaprawy naprawcze i powłoki Przyczepność do podłoża\nZakres (0 - 8) MPa\nMetoda „pull-off” − pomiar przez odrywanie PB/TM-1/6:2024 wydanie 5 z dnia 26.11.2024 r. Zaprawy naprawcze i powloki Przyczepnosc do podloza\nZakres (0 - 8) MPa\nMetoda „pull-off” − pomiar przez odrywanie PB/TM-1/6:2024 wydanie 5 z dnia 26.11.2024 r.","categories":["other"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Repair mortars and coatings Adhesion to the substrate „Pull-off” method − pull-off measurement Range PB/TM-1/6:2024 wydanie 5 z dnia 26.11.2024 r.","parameters_zh":[{"name":"范围","range":"(0 - 8) MPa"}],"search_zh":"修补砂浆与涂层 与基层的粘结强度 范围 PB/TM-1/6:2024 wydanie 5 z dnia 26.11.2024 r.","methodology_zh":"与基层的粘结强度","test_object_zh":"修补砂浆与涂层"},{"_id":"6a5dc9b7f1c10c8ce825d227","lab_id":"69ad52a3de79e566650fb2ee","country":"PL","accr_number":"AB 580","accr_body":"PCA","test_object":"Zaprawy naprawcze i powłoki","test_object_en":"Repair mortars and coatings","methodology":"Mrozoodporność (zaprawy naprawcze)","methodology_en":"Frost resistance (repair mortars)","parameters":[{"name":"Zakres","range":"(50 - 300) cykli"}],"parameters_en":[{"name":"Range","range":"(50 - 300) cykli"}],"technique":"Metoda: bezpośredni pomiar masy i wytrzymałości","techniques":["Metoda: bezpośredni pomiar masy i wytrzymałości"],"technique_en":"Method: direct measurement of mass and strength","computed":[],"computed_en":[],"activity":"Mrozoodporność (zaprawy naprawcze)\nZakres (50 - 300) cykli\nMetoda: bezpośredni pomiar masy i wytrzymałości","reference":"PB/TM-1/12:2024 wydanie 3 z dnia 26.11.2024 r.","norm_bases":["PB/TM-1/12:2024 wydanie 3 z dnia 26.11.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zaprawy naprawcze i powłoki Mrozoodporność (zaprawy naprawcze)\nZakres (50 - 300) cykli\nMetoda: bezpośredni pomiar masy i wytrzymałości PB/TM-1/12:2024 wydanie 3 z dnia 26.11.2024 r. Zaprawy naprawcze i powloki Mrozoodpornosc (zaprawy naprawcze)\nZakres (50 - 300) cykli\nMetoda: bezposredni pomiar masy i wytrzymalosci PB/TM-1/12:2024 wydanie 3 z dnia 26.11.2024 r.","categories":["other"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Repair mortars and coatings Frost resistance (repair mortars) Method: direct measurement of mass and strength Range PB/TM-1/12:2024 wydanie 3 z dnia 26.11.2024 r.","parameters_zh":[{"name":"范围","range":"(50 - 300) cykli"}],"search_zh":"修补砂浆与涂层 范围 PB/TM-1/12:2024 wydanie 3 z dnia 26.11.2024 r.","test_object_zh":"修补砂浆与涂层"},{"_id":"6a5dc9b7f1c10c8ce825d228","lab_id":"69ad52a3de79e566650fb2ee","country":"PL","accr_number":"AB 580","accr_body":"PCA","test_object":"Zaprawy naprawcze i powłoki","test_object_en":"Repair mortars and coatings","methodology":"Stan powłoki (lub wyprawy) ochronnej po próbie mrozoodporności","methodology_en":"Condition of the protective coating (or render) after the frost resistance test","parameters":[{"name":"Zakres","range":"(50 – 300) cykli"}],"parameters_en":[{"name":"Range","range":"(50 – 300) cykli"}],"technique":"Metoda: ocena wizualna","techniques":["Metoda: ocena wizualna"],"technique_en":"Method: visual assessment","computed":[],"computed_en":[],"activity":"Stan powłoki (lub wyprawy) ochronnej po próbie mrozoodporności\nZakres (50 – 300) cykli\nMetoda: ocena wizualna","reference":"PB/TM-1/13:2024 wydanie 2 z dnia 26.11.2024 r.","norm_bases":["PB/TM-1/13:2024 wydanie 2 z dnia 26.11.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zaprawy naprawcze i powłoki Stan powłoki (lub wyprawy) ochronnej po próbie mrozoodporności\nZakres (50 – 300) cykli\nMetoda: ocena wizualna PB/TM-1/13:2024 wydanie 2 z dnia 26.11.2024 r. Zaprawy naprawcze i powloki Stan powloki (lub wyprawy) ochronnej po probie mrozoodpornosci\nZakres (50 – 300) cykli\nMetoda: ocena wizualna PB/TM-1/13:2024 wydanie 2 z dnia 26.11.2024 r.","categories":["other"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Repair mortars and coatings Condition of the protective coating (or render) after the frost resistance test Method: visual assessment Range PB/TM-1/13:2024 wydanie 2 z dnia 26.11.2024 r.","parameters_zh":[{"name":"范围","range":"(50 – 300) cykli"}],"search_zh":"修补砂浆与涂层 方法：目视评定 范围 PB/TM-1/13:2024 wydanie 2 z dnia 26.11.2024 r.","test_object_zh":"修补砂浆与涂层","technique_zh":"方法：目视评定"},{"_id":"6a5dc9b7f1c10c8ce825d229","lab_id":"69ad52a3de79e566650fb2ee","country":"PL","accr_number":"AB 580","accr_body":"PCA","test_object":"Zaprawy naprawcze i powłoki","test_object_en":"Repair mortars and coatings","methodology":"Wytrzymałość na ściskanie (zaprawy naprawcze)","methodology_en":"Compressive strength (repair mortars)","parameters":[{"name":"Zakres","range":"(0 – 250) kN"}],"parameters_en":[{"name":"Range","range":"(0 – 250) kN"}],"technique":"Metoda: bezpośredni pomiar wytrzymałości","techniques":["Metoda: bezpośredni pomiar wytrzymałości"],"technique_en":"Method: direct strength measurement","computed":[],"computed_en":[],"activity":"Wytrzymałość na ściskanie (zaprawy naprawcze)\nZakres (0 – 250) kN\nMetoda: bezpośredni pomiar wytrzymałości","reference":"PN-EN 12190:2000","norm_bases":["PN-EN 12190:2000"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zaprawy naprawcze i powłoki Wytrzymałość na ściskanie (zaprawy naprawcze)\nZakres (0 – 250) kN\nMetoda: bezpośredni pomiar wytrzymałości PN-EN 12190:2000 Zaprawy naprawcze i powloki Wytrzymalosc na sciskanie (zaprawy naprawcze)\nZakres (0 – 250) kN\nMetoda: bezposredni pomiar wytrzymalosci PN-EN 12190:2000","categories":["other"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Repair mortars and coatings Compressive strength (repair mortars) Method: direct strength measurement Range PN-EN 12190:2000","parameters_zh":[{"name":"范围","range":"(0 – 250) kN"}],"search_zh":"修补砂浆与涂层 范围 PN-EN 12190:2000","test_object_zh":"修补砂浆与涂层"},{"_id":"6a5dc9b7f1c10c8ce825d22a","lab_id":"69ad52a3de79e566650fb2ee","country":"PL","accr_number":"AB 580","accr_body":"PCA","test_object":"Zaprawy naprawcze i powłoki","test_object_en":"Repair mortars and coatings","methodology":"Gęstość objętościowa","methodology_en":"Bulk density","parameters":[],"parameters_en":[],"technique":"Metoda: wagowa","techniques":["Metoda: wagowa"],"technique_en":"Method: gravimetric","computed":[],"computed_en":[],"activity":"Gęstość objętościowa\nMetoda: wagowa","reference":"PN-EN 12190:2000","norm_bases":["PN-EN 12190:2000"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zaprawy naprawcze i powłoki Gęstość objętościowa\nMetoda: wagowa PN-EN 12190:2000 Zaprawy naprawcze i powloki Gestosc objetosciowa\nMetoda: wagowa PN-EN 12190:2000","categories":["other"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Repair mortars and coatings Bulk density Method: gravimetric PN-EN 12190:2000","search_zh":"修补砂浆与涂层 堆积密度 方法：重量法 PN-EN 12190:2000","technique_zh":"方法：重量法","methodology_zh":"堆积密度","test_object_zh":"修补砂浆与涂层"},{"_id":"6a5dc9b7f1c10c8ce825d22b","lab_id":"69ad52a3de79e566650fb2ee","country":"PL","accr_number":"AB 580","accr_body":"PCA","test_object":"Zaprawy naprawcze i powłoki","test_object_en":"Repair mortars and coatings","methodology":"Wytrzymałość na zginanie i ściskanie (zaprawy naprawcze)","methodology_en":"Flexural and compressive strength (repair mortars)","parameters":[{"name":"ściskania","range":"(0 - 250) kN"},{"name":"zginanie","range":"(0- 15) kN"}],"parameters_en":[{"name":"compression","range":"(0 - 250) kN"},{"name":"bending","range":"(0- 15) kN"}],"technique":"Metoda: bezpośredni pomiar wytrzymałości","techniques":["Metoda: bezpośredni pomiar wytrzymałości"],"technique_en":"Method: direct strength measurement","computed":[],"computed_en":[],"activity":"Wytrzymałość na zginanie i ściskanie (zaprawy naprawcze)\nZakres:\nściskania (0 - 250) kN\nzginanie (0- 15) kN\nMetoda: bezpośredni pomiar wytrzymałości","reference":"PN-EN 1015-11:2020-04 p. 8 i 9","norm_bases":["PN-EN 1015-11:2020-04 p. 8 i 9"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zaprawy naprawcze i powłoki Wytrzymałość na zginanie i ściskanie (zaprawy naprawcze)\nZakres:\nściskania (0 - 250) kN\nzginanie (0- 15) kN\nMetoda: bezpośredni pomiar wytrzymałości PN-EN 1015-11:2020-04 p. 8 i 9 Zaprawy naprawcze i powloki Wytrzymalosc na zginanie i sciskanie (zaprawy naprawcze)\nZakres:\nsciskania (0 - 250) kN\nzginanie (0- 15) kN\nMetoda: bezposredni pomiar wytrzymalosci PN-EN 1015-11:2020-04 p. 8 i 9","categories":["other"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Repair mortars and coatings Flexural and compressive strength (repair mortars) Method: direct strength measurement compression bending PN-EN 1015-11:2020-04 p. 8 i 9","search_zh":"修补砂浆与涂层 PN-EN 1015-11:2020-04 p. 8 i 9","test_object_zh":"修补砂浆与涂层"},{"_id":"6a5dc9b7f1c10c8ce825d22c","lab_id":"69ad52a3de79e566650fb2ee","country":"PL","accr_number":"AB 580","accr_body":"PCA","test_object":"Zaprawy naprawcze i powłoki","test_object_en":"Repair mortars and coatings","methodology":"Przepuszczalność wody (absorpcja kapilarna powłoki)","methodology_en":"Water permeability (capillary absorption of the coating)","parameters":[],"parameters_en":[],"technique":"Metoda: wagowa","techniques":["Metoda: wagowa"],"technique_en":"Method: gravimetric","computed":[],"computed_en":[],"activity":"Przepuszczalność wody (absorpcja kapilarna powłoki)\nMetoda: wagowa","reference":"PN-EN 1062-3:2008","norm_bases":["PN-EN 1062-3:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zaprawy naprawcze i powłoki Przepuszczalność wody (absorpcja kapilarna powłoki)\nMetoda: wagowa PN-EN 1062-3:2008 Zaprawy naprawcze i powloki Przepuszczalnosc wody (absorpcja kapilarna powloki)\nMetoda: wagowa PN-EN 1062-3:2008","categories":["water"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Repair mortars and coatings Water permeability (capillary absorption of the coating) Method: gravimetric PN-EN 1062-3:2008","search_zh":"修补砂浆与涂层 方法：重量法 PN-EN 1062-3:2008","technique_zh":"方法：重量法","test_object_zh":"修补砂浆与涂层"},{"_id":"6a5dc9b7f1c10c8ce825d22d","lab_id":"69ad52a3de79e566650fb2ee","country":"PL","accr_number":"AB 580","accr_body":"PCA","test_object":"Zaprawy naprawcze i powłoki","test_object_en":"Repair mortars and coatings","methodology":"Absorpcja kapilarna (zapraw)","methodology_en":"Capillary absorption (of mortars)","parameters":[],"parameters_en":[],"technique":"Metoda: wagowa","techniques":["Metoda: wagowa"],"technique_en":"Method: gravimetric","computed":[],"computed_en":[],"activity":"Absorpcja kapilarna (zapraw)\nMetoda: wagowa","reference":"PN-EN 13057:2004","norm_bases":["PN-EN 13057:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zaprawy naprawcze i powłoki Absorpcja kapilarna (zapraw)\nMetoda: wagowa PN-EN 13057:2004 Zaprawy naprawcze i powloki Absorpcja kapilarna (zapraw)\nMetoda: wagowa PN-EN 13057:2004","categories":["other"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Repair mortars and coatings Capillary absorption (of mortars) Method: gravimetric PN-EN 13057:2004","search_zh":"修补砂浆与涂层 方法：重量法 PN-EN 13057:2004","technique_zh":"方法：重量法","test_object_zh":"修补砂浆与涂层"},{"_id":"6a5dc9b7f1c10c8ce825d22e","lab_id":"69ad52a3de79e566650fb2ee","country":"PL","accr_number":"AB 580","accr_body":"PCA","test_object":"Beton w konstrukcjach","test_object_en":"Concrete in structures","methodology":"Liczba odbicia","methodology_en":"Rebound number","parameters":[{"name":"Zakres","range":"(20 – 85) jednostek"}],"parameters_en":[{"name":"Range","range":"(20 – 85) jednostek"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Liczba odbicia\nZakres (20 – 85) jednostek\nMetoda: pomiar bezpośredni","reference":"PN-EN 12504-2:2013-03","norm_bases":["PN-EN 12504-2:2013-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Beton w konstrukcjach Liczba odbicia\nZakres (20 – 85) jednostek\nMetoda: pomiar bezpośredni PN-EN 12504-2:2013-03 Beton w konstrukcjach Liczba odbicia\nZakres (20 – 85) jednostek\nMetoda: pomiar bezposredni PN-EN 12504-2:2013-03","categories":["construction"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Concrete in structures Rebound number Method: direct measurement Range PN-EN 12504-2:2013-03","parameters_zh":[{"name":"范围","range":"(20 – 85) jednostek"}],"search_zh":"结构中的混凝土 方法：直接测量 范围 PN-EN 12504-2:2013-03","technique_zh":"方法：直接测量","test_object_zh":"结构中的混凝土"}],"has_pdf":true}