{"lab":{"_id":"69ad52a3de79e566650fb2e0","accr_number":"AB 567","country":"PL","accr_body":"PCA","address":"LABORATORIUM POMIARÓW DOZYMETRYCZNYCH, DZIAŁ POMIARÓW SKAŻEŃ, ul. A. Sołtana 7, 05 - 400 Otwock","categories":["environment","materials"],"city":"Otwock","imported_at":"2026-03-08T10:42:43.265Z","methods_count":24,"name":"NARODOWE CENTRUM BADAŃ JĄDROWYCH","parse_status":"parsed","parse_version":2,"pdf_files":["AB_567.pdf"],"scope_summary":"","search_text":"narodowe centrum badań jądrowych laboratorium pomiarów dozymetrycznych, dział pomiarów skażeń, ul. a. sołtana 7, 05 - 400 otwock other metrology environment water materials","status":"active","updated_at":"2026-03-08T14:51:27.346Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:27.346Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20567,podmiot.html","fields_of_testing":[{"codes":"O/3, O/9, O/28, O/30, O/34","pl":"Badania radiochemiczne i promieniowania – w tym nuklearne w obiektach i materiałach biologicznych przeznaczonych do badań, w środowisku ogólnym, w powietrzu, wodzie, ściekach","en":"Radiochemical tests and tests of radiation – including nuclear radiation in the biological items and materials for testing, general environment, air, water, sewage"}],"issue":{"no":"19","date":"30.09.2025"},"parse_date":"2026-07-20T20:42:15.089Z","parse_source":"script-pdfplumber","map_coord":[52.10412,21.268109],"map_geo":"nominatim-city","has_en":true,"category_counts":{"other":18,"environment":3,"materials":2,"water":1},"category_scores":{"other":13.5,"environment":0.38,"materials":0.17,"water":0.04},"has_zh":true},"methods":[{"_id":"6a5e8827b979cd801f483499","lab_id":"69ad52a3de79e566650fb2e0","country":"PL","accr_number":"AB 567","accr_body":"PCA","test_object":"Ciało człowieka (pomiar in-vivo)","test_object_en":"Human body (in-vivo measurement)","methodology":"Stężenie aktywności radionuklidów gamma promieniotwórczych w ciele człowieka w zakresie energii 60 keV - 2100 keV","methodology_en":"Activity concentration of gamma-emitting radionuclides in the human body in the energy range 60 keV - 2100 keV","parameters":[{"name":"Zakres","range":"0,5 Bq/kg - 10 kBq/kg"}],"parameters_en":[{"name":"Range","range":"0,5 Bq/kg - 10 kBq/kg"}],"technique":"Metoda spektrometrii promieniowania gamma","techniques":["Metoda spektrometrii promieniowania gamma"],"technique_en":"Gamma-ray spectrometry method","computed":[],"computed_en":[],"activity":"Stężenie aktywności radionuklidów gamma promieniotwórczych w ciele człowieka w zakresie energii 60 keV - 2100 keV\nZakres 0,5 Bq/kg - 10 kBq/kg\nMetoda spektrometrii promieniowania gamma","reference":"Procedura operacyjna C-1 wydanie 7 z dnia 03.06.2025 r.","norm_bases":["Procedura operacyjna C-1 wydanie 7 z dnia 03.06.2025 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ciało człowieka (pomiar in-vivo) Stężenie aktywności radionuklidów gamma promieniotwórczych w ciele człowieka w zakresie energii 60 keV - 2100 keV\nZakres 0,5 Bq/kg - 10 kBq/kg\nMetoda spektrometrii promieniowania gamma Procedura operacyjna C-1 wydanie 7 z dnia 03.06.2025 r. Cialo czlowieka (pomiar in-vivo) Stezenie aktywnosci radionuklidow gamma promieniotworczych w ciele czlowieka w zakresie energii 60 keV - 2100 keV\nZakres 0,5 Bq/kg - 10 kBq/kg\nMetoda spektrometrii promieniowania gamma Procedura operacyjna C-1 wydanie 7 z dnia 03.06.2025 r.","categories":["other"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Human body (in-vivo measurement) Activity concentration of gamma-emitting radionuclides in the human body in the energy range 60 keV - 2100 keV Gamma-ray spectrometry method Range Procedura operacyjna C-1 wydanie 7 z dnia 03.06.2025 r.","parameters_zh":[{"name":"范围","range":"0,5 Bq/kg - 10 kBq/kg"}],"search_zh":"γ 能谱法 范围 Procedura operacyjna C-1 wydanie 7 z dnia 03.06.2025 r.","technique_zh":"γ 能谱法"},{"_id":"6a5e8827b979cd801f48349a","lab_id":"69ad52a3de79e566650fb2e0","country":"PL","accr_number":"AB 567","accr_body":"PCA","test_object":"Ciało człowieka (pomiar in-vivo)","test_object_en":"Human body (in-vivo measurement)","methodology":"Skuteczna dawka obciążająca (z obliczeń)","methodology_en":"Committed effective dose (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Skuteczna dawka obciążająca (z obliczeń)","reference":"Procedura operacyjna C-1 wydanie 7 z dnia 03.06.2025 r.","norm_bases":["Procedura operacyjna C-1 wydanie 7 z dnia 03.06.2025 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ciało człowieka (pomiar in-vivo) Skuteczna dawka obciążająca (z obliczeń) Procedura operacyjna C-1 wydanie 7 z dnia 03.06.2025 r. Cialo czlowieka (pomiar in-vivo) Skuteczna dawka obciazajaca (z obliczen) Procedura operacyjna C-1 wydanie 7 z dnia 03.06.2025 r.","categories":["other"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Human body (in-vivo measurement) Committed effective dose (calculated) Procedura operacyjna C-1 wydanie 7 z dnia 03.06.2025 r.","methodology_zh":"待积有效剂量（由计算得出）","search_zh":"待积有效剂量（由计算得出） Procedura operacyjna C-1 wydanie 7 z dnia 03.06.2025 r."},{"_id":"6a5e8827b979cd801f48349b","lab_id":"69ad52a3de79e566650fb2e0","country":"PL","accr_number":"AB 567","accr_body":"PCA","test_object":"Tarczyca człowieka (pomiar in-vivo)","test_object_en":"Human thyroid (in-vivo measurement)","methodology":"Stężenie aktywności radionuklidu","methodology_en":"Radionuclide activity concentration","parameters":[{"name":"Stężenie aktywności radionuklidu","range":"131l"},{"name":"w zakresie energii 20 keV - 500 keV"},{"name":"Zakres","range":"200 Bq - 100 kBq"}],"parameters_en":[{"name":"Radionuclide activity concentration","range":"131l"},{"name":"in the energy range 20 keV - 500 keV"},{"name":"Range","range":"200 Bq - 100 kBq"}],"technique":"Metoda spektrometrii promieniowania gamma","techniques":["Metoda spektrometrii promieniowania gamma"],"technique_en":"Gamma-ray spectrometry method","computed":[],"computed_en":[],"activity":"Stężenie aktywności radionuklidu\nZakres:\nStężenie aktywności radionuklidu 131l\nw zakresie energii 20 keV - 500 keV\nZakres 200 Bq - 100 kBq\nMetoda spektrometrii promieniowania gamma","reference":"Procedura operacyjna T-1 wydanie 5 z dnia 03.06.2025 r.","norm_bases":["Procedura operacyjna T-1 wydanie 5 z dnia 03.06.2025 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Tarczyca człowieka (pomiar in-vivo) Stężenie aktywności radionuklidu\nZakres:\nStężenie aktywności radionuklidu 131l\nw zakresie energii 20 keV - 500 keV\nZakres 200 Bq - 100 kBq\nMetoda spektrometrii promieniowania gamma Procedura operacyjna T-1 wydanie 5 z dnia 03.06.2025 r. Tarczyca czlowieka (pomiar in-vivo) Stezenie aktywnosci radionuklidu\nZakres:\nStezenie aktywnosci radionuklidu 131l\nw zakresie energii 20 keV - 500 keV\nZakres 200 Bq - 100 kBq\nMetoda spektrometrii promieniowania gamma Procedura operacyjna T-1 wydanie 5 z dnia 03.06.2025 r.","categories":["other"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Human thyroid (in-vivo measurement) Radionuclide activity concentration Gamma-ray spectrometry method Radionuclide activity concentration in the energy range 20 keV - 500 keV Range Procedura operacyjna T-1 wydanie 5 z dnia 03.06.2025 r.","parameters_zh":[{"name":"放射性核素活度浓度","range":"131l"},{"name":"w zakresie energii 20 keV - 500 keV"},{"name":"范围","range":"200 Bq - 100 kBq"}],"search_zh":"放射性核素活度浓度 γ 能谱法 放射性核素活度浓度 范围 Procedura operacyjna T-1 wydanie 5 z dnia 03.06.2025 r.","methodology_zh":"放射性核素活度浓度","technique_zh":"γ 能谱法"},{"_id":"6a5e8827b979cd801f48349c","lab_id":"69ad52a3de79e566650fb2e0","country":"PL","accr_number":"AB 567","accr_body":"PCA","test_object":"Tarczyca człowieka (pomiar in-vivo)","test_object_en":"Human thyroid (in-vivo measurement)","methodology":"Skuteczna dawka obciążająca (z obliczeń)","methodology_en":"Committed effective dose (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Skuteczna dawka obciążająca (z obliczeń)","reference":"Procedura operacyjna T-1 wydanie 5 z dnia 03.06.2025 r.","norm_bases":["Procedura operacyjna T-1 wydanie 5 z dnia 03.06.2025 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Tarczyca człowieka (pomiar in-vivo) Skuteczna dawka obciążająca (z obliczeń) Procedura operacyjna T-1 wydanie 5 z dnia 03.06.2025 r. Tarczyca czlowieka (pomiar in-vivo) Skuteczna dawka obciazajaca (z obliczen) Procedura operacyjna T-1 wydanie 5 z dnia 03.06.2025 r.","categories":["other"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Human thyroid (in-vivo measurement) Committed effective dose (calculated) Procedura operacyjna T-1 wydanie 5 z dnia 03.06.2025 r.","methodology_zh":"待积有效剂量（由计算得出）","search_zh":"待积有效剂量（由计算得出） Procedura operacyjna T-1 wydanie 5 z dnia 03.06.2025 r."},{"_id":"6a5e8827b979cd801f48349d","lab_id":"69ad52a3de79e566650fb2e0","country":"PL","accr_number":"AB 567","accr_body":"PCA","test_object":"Mocz człowieka (pomiar in-vitro)","test_object_en":"Human urine (in-vitro measurement)","methodology":"Stężenie aktywności radionuklidu: 3H","methodology_en":"Activity concentration of radionuclide: 3H","parameters":[{"name":"Zakres","range":"10 Bq/ dm3 - 10 kBq/dm3"}],"parameters_en":[{"name":"Range","range":"10 Bq/ dm3 - 10 kBq/dm3"}],"technique":"Metoda ciekłej scyntylacji (LSC)","techniques":["Metoda ciekłej scyntylacji (LSC)"],"technique_en":"Liquid scintillation method (LSC)","computed":[],"computed_en":[],"activity":"Stężenie aktywności radionuklidu: 3H\nZakres 10 Bq/ dm3 - 10 kBq/dm3\nMetoda ciekłej scyntylacji (LSC)","reference":"Procedura operacyjna W-4 wydanie 6 z dnia 13.03.2020 r.","norm_bases":["Procedura operacyjna W-4 wydanie 6 z dnia 13.03.2020 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mocz człowieka (pomiar in-vitro) Stężenie aktywności radionuklidu: 3H\nZakres 10 Bq/ dm3 - 10 kBq/dm3\nMetoda ciekłej scyntylacji (LSC) Procedura operacyjna W-4 wydanie 6 z dnia 13.03.2020 r. Mocz czlowieka (pomiar in-vitro) Stezenie aktywnosci radionuklidu: 3H\nZakres 10 Bq/ dm3 - 10 kBq/dm3\nMetoda cieklej scyntylacji (LSC) Procedura operacyjna W-4 wydanie 6 z dnia 13.03.2020 r.","categories":["other"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Human urine (in-vitro measurement) Activity concentration of radionuclide: 3H Liquid scintillation method (LSC) Range Procedura operacyjna W-4 wydanie 6 z dnia 13.03.2020 r.","parameters_zh":[{"name":"范围","range":"10 Bq/ dm3 - 10 kBq/dm3"}],"search_zh":"人尿（体外测定） 液体闪烁计数法（LSC） 范围 Procedura operacyjna W-4 wydanie 6 z dnia 13.03.2020 r.","test_object_zh":"人尿（体外测定）","technique_zh":"液体闪烁计数法（LSC）"},{"_id":"6a5e8827b979cd801f48349e","lab_id":"69ad52a3de79e566650fb2e0","country":"PL","accr_number":"AB 567","accr_body":"PCA","test_object":"Mocz człowieka (pomiar in-vitro)","test_object_en":"Human urine (in-vitro measurement)","methodology":"Skuteczna dawka obciążająca (z obliczeń)","methodology_en":"Committed effective dose (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Skuteczna dawka obciążająca (z obliczeń)","reference":"Procedura operacyjna W-4 wydanie 6 z dnia 13.03.2020 r.","norm_bases":["Procedura operacyjna W-4 wydanie 6 z dnia 13.03.2020 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mocz człowieka (pomiar in-vitro) Skuteczna dawka obciążająca (z obliczeń) Procedura operacyjna W-4 wydanie 6 z dnia 13.03.2020 r. Mocz czlowieka (pomiar in-vitro) Skuteczna dawka obciazajaca (z obliczen) Procedura operacyjna W-4 wydanie 6 z dnia 13.03.2020 r.","categories":["other"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Human urine (in-vitro measurement) Committed effective dose (calculated) Procedura operacyjna W-4 wydanie 6 z dnia 13.03.2020 r.","methodology_zh":"待积有效剂量（由计算得出）","search_zh":"人尿（体外测定） 待积有效剂量（由计算得出） Procedura operacyjna W-4 wydanie 6 z dnia 13.03.2020 r.","test_object_zh":"人尿（体外测定）"},{"_id":"6a5e8827b979cd801f48349f","lab_id":"69ad52a3de79e566650fb2e0","country":"PL","accr_number":"AB 567","accr_body":"PCA","test_object":"Mocz człowieka (pomiar in-vitro)","test_object_en":"Human urine (in-vitro measurement)","methodology":"Stężenie aktywności radionuklidu","methodology_en":"Radionuclide activity concentration","parameters":[{"name":"Stężenie aktywności radionuklidu","range":"35S"},{"name":"Zakres","range":"10 Bq/ dm3 - 1 kBq/dm3"}],"parameters_en":[{"name":"Radionuclide activity concentration","range":"35S"},{"name":"Range","range":"10 Bq/ dm3 - 1 kBq/dm3"}],"technique":"Metoda ciekłej scyntylacji (LSC)","techniques":["Metoda ciekłej scyntylacji (LSC)"],"technique_en":"Liquid scintillation method (LSC)","computed":[],"computed_en":[],"activity":"Stężenie aktywności radionuklidu\nZakres:\nStężenie aktywności radionuklidu 35S\nZakres 10 Bq/ dm3 - 1 kBq/dm3\nMetoda ciekłej scyntylacji (LSC)","reference":"Procedura operacyjna W-6 wydanie 5 z dnia 15.02.2012 r.","norm_bases":["Procedura operacyjna W-6 wydanie 5 z dnia 15.02.2012 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mocz człowieka (pomiar in-vitro) Stężenie aktywności radionuklidu\nZakres:\nStężenie aktywności radionuklidu 35S\nZakres 10 Bq/ dm3 - 1 kBq/dm3\nMetoda ciekłej scyntylacji (LSC) Procedura operacyjna W-6 wydanie 5 z dnia 15.02.2012 r. Mocz czlowieka (pomiar in-vitro) Stezenie aktywnosci radionuklidu\nZakres:\nStezenie aktywnosci radionuklidu 35S\nZakres 10 Bq/ dm3 - 1 kBq/dm3\nMetoda cieklej scyntylacji (LSC) Procedura operacyjna W-6 wydanie 5 z dnia 15.02.2012 r.","categories":["other"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Human urine (in-vitro measurement) Radionuclide activity concentration Liquid scintillation method (LSC) Radionuclide activity concentration Range Procedura operacyjna W-6 wydanie 5 z dnia 15.02.2012 r.","parameters_zh":[{"name":"放射性核素活度浓度","range":"35S"},{"name":"范围","range":"10 Bq/ dm3 - 1 kBq/dm3"}],"search_zh":"人尿（体外测定） 放射性核素活度浓度 液体闪烁计数法（LSC） 放射性核素活度浓度 范围 Procedura operacyjna W-6 wydanie 5 z dnia 15.02.2012 r.","methodology_zh":"放射性核素活度浓度","test_object_zh":"人尿（体外测定）","technique_zh":"液体闪烁计数法（LSC）"},{"_id":"6a5e8827b979cd801f4834a0","lab_id":"69ad52a3de79e566650fb2e0","country":"PL","accr_number":"AB 567","accr_body":"PCA","test_object":"Mocz człowieka (pomiar in-vitro)","test_object_en":"Human urine (in-vitro measurement)","methodology":"Skuteczna dawka obciążająca (z obliczeń)","methodology_en":"Committed effective dose (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Skuteczna dawka obciążająca (z obliczeń)","reference":"Procedura operacyjna W-6 wydanie 5 z dnia 15.02.2012 r.","norm_bases":["Procedura operacyjna W-6 wydanie 5 z dnia 15.02.2012 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mocz człowieka (pomiar in-vitro) Skuteczna dawka obciążająca (z obliczeń) Procedura operacyjna W-6 wydanie 5 z dnia 15.02.2012 r. Mocz czlowieka (pomiar in-vitro) Skuteczna dawka obciazajaca (z obliczen) Procedura operacyjna W-6 wydanie 5 z dnia 15.02.2012 r.","categories":["other"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Human urine (in-vitro measurement) Committed effective dose (calculated) Procedura operacyjna W-6 wydanie 5 z dnia 15.02.2012 r.","methodology_zh":"待积有效剂量（由计算得出）","search_zh":"人尿（体外测定） 待积有效剂量（由计算得出） Procedura operacyjna W-6 wydanie 5 z dnia 15.02.2012 r.","test_object_zh":"人尿（体外测定）"},{"_id":"6a5e8827b979cd801f4834a1","lab_id":"69ad52a3de79e566650fb2e0","country":"PL","accr_number":"AB 567","accr_body":"PCA","test_object":"Mocz człowieka (pomiar in-vitro)","test_object_en":"Human urine (in-vitro measurement)","methodology":"Stężenie aktywności radionuklidu","methodology_en":"Radionuclide activity concentration","parameters":[{"name":"Stężenie aktywności radionuklidu","range":"32P"},{"name":"Zakres","range":"10 Bq/ dm3 - 1 kBq/dm3"}],"parameters_en":[{"name":"Radionuclide activity concentration","range":"32P"},{"name":"Range","range":"10 Bq/ dm3 - 1 kBq/dm3"}],"technique":"Metoda ciekłej scyntylacji (LSC)","techniques":["Metoda ciekłej scyntylacji (LSC)"],"technique_en":"Liquid scintillation method (LSC)","computed":[],"computed_en":[],"activity":"Stężenie aktywności radionuklidu\nZakres:\nStężenie aktywności radionuklidu 32P\nZakres 10 Bq/ dm3 - 1 kBq/dm3\nMetoda ciekłej scyntylacji (LSC)","reference":"Procedura operacyjna W-5 wydanie 5 z dnia 15.02.2012 r.","norm_bases":["Procedura operacyjna W-5 wydanie 5 z dnia 15.02.2012 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mocz człowieka (pomiar in-vitro) Stężenie aktywności radionuklidu\nZakres:\nStężenie aktywności radionuklidu 32P\nZakres 10 Bq/ dm3 - 1 kBq/dm3\nMetoda ciekłej scyntylacji (LSC) Procedura operacyjna W-5 wydanie 5 z dnia 15.02.2012 r. Mocz czlowieka (pomiar in-vitro) Stezenie aktywnosci radionuklidu\nZakres:\nStezenie aktywnosci radionuklidu 32P\nZakres 10 Bq/ dm3 - 1 kBq/dm3\nMetoda cieklej scyntylacji (LSC) Procedura operacyjna W-5 wydanie 5 z dnia 15.02.2012 r.","categories":["other"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Human urine (in-vitro measurement) Radionuclide activity concentration Liquid scintillation method (LSC) Radionuclide activity concentration Range Procedura operacyjna W-5 wydanie 5 z dnia 15.02.2012 r.","parameters_zh":[{"name":"放射性核素活度浓度","range":"32P"},{"name":"范围","range":"10 Bq/ dm3 - 1 kBq/dm3"}],"search_zh":"人尿（体外测定） 放射性核素活度浓度 液体闪烁计数法（LSC） 放射性核素活度浓度 范围 Procedura operacyjna W-5 wydanie 5 z dnia 15.02.2012 r.","methodology_zh":"放射性核素活度浓度","test_object_zh":"人尿（体外测定）","technique_zh":"液体闪烁计数法（LSC）"},{"_id":"6a5e8827b979cd801f4834a2","lab_id":"69ad52a3de79e566650fb2e0","country":"PL","accr_number":"AB 567","accr_body":"PCA","test_object":"Mocz człowieka (pomiar in-vitro)","test_object_en":"Human urine (in-vitro measurement)","methodology":"Skuteczna dawka obciążająca (z obliczeń)","methodology_en":"Committed effective dose (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Skuteczna dawka obciążająca (z obliczeń)","reference":"Procedura operacyjna W-5 wydanie 5 z dnia 15.02.2012 r.","norm_bases":["Procedura operacyjna W-5 wydanie 5 z dnia 15.02.2012 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mocz człowieka (pomiar in-vitro) Skuteczna dawka obciążająca (z obliczeń) Procedura operacyjna W-5 wydanie 5 z dnia 15.02.2012 r. Mocz czlowieka (pomiar in-vitro) Skuteczna dawka obciazajaca (z obliczen) Procedura operacyjna W-5 wydanie 5 z dnia 15.02.2012 r.","categories":["other"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Human urine (in-vitro measurement) Committed effective dose (calculated) Procedura operacyjna W-5 wydanie 5 z dnia 15.02.2012 r.","methodology_zh":"待积有效剂量（由计算得出）","search_zh":"人尿（体外测定） 待积有效剂量（由计算得出） Procedura operacyjna W-5 wydanie 5 z dnia 15.02.2012 r.","test_object_zh":"人尿（体外测定）"},{"_id":"6a5e8827b979cd801f4834a3","lab_id":"69ad52a3de79e566650fb2e0","country":"PL","accr_number":"AB 567","accr_body":"PCA","test_object":"Mocz człowieka (pomiar in-vitro)","test_object_en":"Human urine (in-vitro measurement)","methodology":"Stężenie aktywności radionuklidu","methodology_en":"Radionuclide activity concentration","parameters":[{"name":"Stężenie aktywności radionuklidu","range":"90Sr"},{"name":"lub 90Y"},{"name":"Zakres","range":"0,04 Bq/ dm3 - 10 kBq/dm3"},{"name":"Licznik proporcjonalny"}],"parameters_en":[{"name":"Radionuclide activity concentration","range":"90Sr"},{"name":"or 90Y"},{"name":"Range","range":"0,04 Bq/ dm3 - 10 kBq/dm3"},{"name":"Proportional counter"}],"technique":"Metoda ciekłej scyntylacji (LSC)","techniques":["Metoda ciekłej scyntylacji (LSC)"],"technique_en":"Liquid scintillation method (LSC)","computed":[],"computed_en":[],"activity":"Stężenie aktywności radionuklidu\nZakres:\nStężenie aktywności radionuklidu 90Sr\nlub 90Y\nZakres 0,04 Bq/ dm3 - 10 kBq/dm3\nLicznik proporcjonalny\nMetoda ciekłej scyntylacji (LSC)","reference":"Procedura operacyjna W-8 wydanie 5 z dnia 15.02.2012 r.","norm_bases":["Procedura operacyjna W-8 wydanie 5 z dnia 15.02.2012 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mocz człowieka (pomiar in-vitro) Stężenie aktywności radionuklidu\nZakres:\nStężenie aktywności radionuklidu 90Sr\nlub 90Y\nZakres 0,04 Bq/ dm3 - 10 kBq/dm3\nLicznik proporcjonalny\nMetoda ciekłej scyntylacji (LSC) Procedura operacyjna W-8 wydanie 5 z dnia 15.02.2012 r. Mocz czlowieka (pomiar in-vitro) Stezenie aktywnosci radionuklidu\nZakres:\nStezenie aktywnosci radionuklidu 90Sr\nlub 90Y\nZakres 0,04 Bq/ dm3 - 10 kBq/dm3\nLicznik proporcjonalny\nMetoda cieklej scyntylacji (LSC) Procedura operacyjna W-8 wydanie 5 z dnia 15.02.2012 r.","categories":["other"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Human urine (in-vitro measurement) Radionuclide activity concentration Liquid scintillation method (LSC) Radionuclide activity concentration or 90Y Range Proportional counter Procedura operacyjna W-8 wydanie 5 z dnia 15.02.2012 r.","parameters_zh":[{"name":"放射性核素活度浓度","range":"90Sr"},{"name":"lub 90Y"},{"name":"范围","range":"0,04 Bq/ dm3 - 10 kBq/dm3"},{"name":"Licznik proporcjonalny"}],"search_zh":"人尿（体外测定） 放射性核素活度浓度 液体闪烁计数法（LSC） 放射性核素活度浓度 范围 Procedura operacyjna W-8 wydanie 5 z dnia 15.02.2012 r.","methodology_zh":"放射性核素活度浓度","test_object_zh":"人尿（体外测定）","technique_zh":"液体闪烁计数法（LSC）"},{"_id":"6a5e8827b979cd801f4834a4","lab_id":"69ad52a3de79e566650fb2e0","country":"PL","accr_number":"AB 567","accr_body":"PCA","test_object":"Mocz człowieka (pomiar in-vitro)","test_object_en":"Human urine (in-vitro measurement)","methodology":"Skuteczna dawka obciążająca (z obliczeń)","methodology_en":"Committed effective dose (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Skuteczna dawka obciążająca (z obliczeń)","reference":"Procedura operacyjna W-8 wydanie 5 z dnia 15.02.2012 r.","norm_bases":["Procedura operacyjna W-8 wydanie 5 z dnia 15.02.2012 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mocz człowieka (pomiar in-vitro) Skuteczna dawka obciążająca (z obliczeń) Procedura operacyjna W-8 wydanie 5 z dnia 15.02.2012 r. Mocz czlowieka (pomiar in-vitro) Skuteczna dawka obciazajaca (z obliczen) Procedura operacyjna W-8 wydanie 5 z dnia 15.02.2012 r.","categories":["other"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Human urine (in-vitro measurement) Committed effective dose (calculated) Procedura operacyjna W-8 wydanie 5 z dnia 15.02.2012 r.","methodology_zh":"待积有效剂量（由计算得出）","search_zh":"人尿（体外测定） 待积有效剂量（由计算得出） Procedura operacyjna W-8 wydanie 5 z dnia 15.02.2012 r.","test_object_zh":"人尿（体外测定）"},{"_id":"6a5e8827b979cd801f4834a5","lab_id":"69ad52a3de79e566650fb2e0","country":"PL","accr_number":"AB 567","accr_body":"PCA","test_object":"Mocz człowieka (pomiar in-vitro)","test_object_en":"Human urine (in-vitro measurement)","methodology":"Stężenie aktywności radionuklidów: 238Pu i 239+240Pu","methodology_en":"Activity concentration of radionuclides: 238Pu and 239+240Pu","parameters":[{"name":"Zakres","range":"(0,1– 150) mBq/dm3"}],"parameters_en":[{"name":"Range","range":"(0,1– 150) mBq/dm3"}],"technique":"Metoda spektrometrii promieniowania alfa","techniques":["Metoda spektrometrii promieniowania alfa"],"technique_en":"Alpha spectrometry method","computed":[],"computed_en":[],"activity":"Stężenie aktywności radionuklidów: 238Pu i 239+240Pu\nZakres (0,1– 150) mBq/dm3\nMetoda spektrometrii promieniowania alfa","reference":"Procedura operacyjna W-9 wydanie 1 z dnia 14.01.2013 r.","norm_bases":["Procedura operacyjna W-9 wydanie 1 z dnia 14.01.2013 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mocz człowieka (pomiar in-vitro) Stężenie aktywności radionuklidów: 238Pu i 239+240Pu\nZakres (0,1– 150) mBq/dm3\nMetoda spektrometrii promieniowania alfa Procedura operacyjna W-9 wydanie 1 z dnia 14.01.2013 r. Mocz czlowieka (pomiar in-vitro) Stezenie aktywnosci radionuklidow: 238Pu i 239+240Pu\nZakres (0,1– 150) mBq/dm3\nMetoda spektrometrii promieniowania alfa Procedura operacyjna W-9 wydanie 1 z dnia 14.01.2013 r.","categories":["other"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Human urine (in-vitro measurement) Activity concentration of radionuclides: 238Pu and 239+240Pu Alpha spectrometry method Range Procedura operacyjna W-9 wydanie 1 z dnia 14.01.2013 r.","parameters_zh":[{"name":"范围","range":"(0,1– 150) mBq/dm3"}],"search_zh":"人尿（体外测定） α 能谱法 范围 Procedura operacyjna W-9 wydanie 1 z dnia 14.01.2013 r.","test_object_zh":"人尿（体外测定）","technique_zh":"α 能谱法"},{"_id":"6a5e8827b979cd801f4834a6","lab_id":"69ad52a3de79e566650fb2e0","country":"PL","accr_number":"AB 567","accr_body":"PCA","test_object":"Mocz człowieka (pomiar in-vitro)","test_object_en":"Human urine (in-vitro measurement)","methodology":"Skuteczna dawka obciążająca (z obliczeń)","methodology_en":"Committed effective dose (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Skuteczna dawka obciążająca (z obliczeń)","reference":"Procedura operacyjna W-9 wydanie 1 z dnia 14.01.2013 r.","norm_bases":["Procedura operacyjna W-9 wydanie 1 z dnia 14.01.2013 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mocz człowieka (pomiar in-vitro) Skuteczna dawka obciążająca (z obliczeń) Procedura operacyjna W-9 wydanie 1 z dnia 14.01.2013 r. Mocz czlowieka (pomiar in-vitro) Skuteczna dawka obciazajaca (z obliczen) Procedura operacyjna W-9 wydanie 1 z dnia 14.01.2013 r.","categories":["other"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Human urine (in-vitro measurement) Committed effective dose (calculated) Procedura operacyjna W-9 wydanie 1 z dnia 14.01.2013 r.","methodology_zh":"待积有效剂量（由计算得出）","search_zh":"人尿（体外测定） 待积有效剂量（由计算得出） Procedura operacyjna W-9 wydanie 1 z dnia 14.01.2013 r.","test_object_zh":"人尿（体外测定）"},{"_id":"6a5e8827b979cd801f4834a7","lab_id":"69ad52a3de79e566650fb2e0","country":"PL","accr_number":"AB 567","accr_body":"PCA","test_object":"Mocz człowieka (pomiar in-vitro)","test_object_en":"Human urine (in-vitro measurement)","methodology":"Stężenie aktywności radionuklidu: 210Po","methodology_en":"Activity concentration of radionuclide: 210Po","parameters":[{"name":"Zakres","range":"(1,5– 1000) mBq/dm3"}],"parameters_en":[{"name":"Range","range":"(1,5– 1000) mBq/dm3"}],"technique":"Metoda spektrometrii promieniowania alfa","techniques":["Metoda spektrometrii promieniowania alfa"],"technique_en":"Alpha spectrometry method","computed":[],"computed_en":[],"activity":"Stężenie aktywności radionuklidu: 210Po\nZakres (1,5– 1000) mBq/dm3\nMetoda spektrometrii promieniowania alfa","reference":"Procedura operacyjna W-11 wydanie 3 z dnia 24.01.2020 r.","norm_bases":["Procedura operacyjna W-11 wydanie 3 z dnia 24.01.2020 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mocz człowieka (pomiar in-vitro) Stężenie aktywności radionuklidu: 210Po\nZakres (1,5– 1000) mBq/dm3\nMetoda spektrometrii promieniowania alfa Procedura operacyjna W-11 wydanie 3 z dnia 24.01.2020 r. Mocz czlowieka (pomiar in-vitro) Stezenie aktywnosci radionuklidu: 210Po\nZakres (1,5– 1000) mBq/dm3\nMetoda spektrometrii promieniowania alfa Procedura operacyjna W-11 wydanie 3 z dnia 24.01.2020 r.","categories":["other"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Human urine (in-vitro measurement) Activity concentration of radionuclide: 210Po Alpha spectrometry method Range Procedura operacyjna W-11 wydanie 3 z dnia 24.01.2020 r.","parameters_zh":[{"name":"范围","range":"(1,5– 1000) mBq/dm3"}],"search_zh":"人尿（体外测定） α 能谱法 范围 Procedura operacyjna W-11 wydanie 3 z dnia 24.01.2020 r.","test_object_zh":"人尿（体外测定）","technique_zh":"α 能谱法"},{"_id":"6a5e8827b979cd801f4834a8","lab_id":"69ad52a3de79e566650fb2e0","country":"PL","accr_number":"AB 567","accr_body":"PCA","test_object":"Mocz człowieka (pomiar in-vitro)","test_object_en":"Human urine (in-vitro measurement)","methodology":"Skuteczna dawka obciążająca (z obliczeń)","methodology_en":"Committed effective dose (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Skuteczna dawka obciążająca (z obliczeń)","reference":"Procedura operacyjna W-11 wydanie 3 z dnia 24.01.2020 r.","norm_bases":["Procedura operacyjna W-11 wydanie 3 z dnia 24.01.2020 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mocz człowieka (pomiar in-vitro) Skuteczna dawka obciążająca (z obliczeń) Procedura operacyjna W-11 wydanie 3 z dnia 24.01.2020 r. Mocz czlowieka (pomiar in-vitro) Skuteczna dawka obciazajaca (z obliczen) Procedura operacyjna W-11 wydanie 3 z dnia 24.01.2020 r.","categories":["other"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Human urine (in-vitro measurement) Committed effective dose (calculated) Procedura operacyjna W-11 wydanie 3 z dnia 24.01.2020 r.","methodology_zh":"待积有效剂量（由计算得出）","search_zh":"人尿（体外测定） 待积有效剂量（由计算得出） Procedura operacyjna W-11 wydanie 3 z dnia 24.01.2020 r.","test_object_zh":"人尿（体外测定）"},{"_id":"6a5e8827b979cd801f4834a9","lab_id":"69ad52a3de79e566650fb2e0","country":"PL","accr_number":"AB 567","accr_body":"PCA","test_object":"Mocz człowieka (pomiar in-vitro)","test_object_en":"Human urine (in-vitro measurement)","methodology":"Całkowita aktywność izotopów beta promieniotwórczych","methodology_en":"Total activity of beta-emitting radioactive isotopes","parameters":[{"name":"Zakres","range":"(0,1 – 10) Bq/dm3"}],"parameters_en":[{"name":"Range","range":"(0,1 – 10) Bq/dm3"}],"technique":"Metoda radiochemiczna","techniques":["Metoda radiochemiczna"],"technique_en":"Radiochemical method","computed":[],"computed_en":[],"activity":"Całkowita aktywność izotopów beta promieniotwórczych\nZakres (0,1 – 10) Bq/dm3\nMetoda radiochemiczna","reference":"Procedura operacyjna W-3 wydanie 5 z dnia 06.04.2021 r.","norm_bases":["Procedura operacyjna W-3 wydanie 5 z dnia 06.04.2021 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mocz człowieka (pomiar in-vitro) Całkowita aktywność izotopów beta promieniotwórczych\nZakres (0,1 – 10) Bq/dm3\nMetoda radiochemiczna Procedura operacyjna W-3 wydanie 5 z dnia 06.04.2021 r. Mocz czlowieka (pomiar in-vitro) Calkowita aktywnosc izotopow beta promieniotworczych\nZakres (0,1 – 10) Bq/dm3\nMetoda radiochemiczna Procedura operacyjna W-3 wydanie 5 z dnia 06.04.2021 r.","categories":["other"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Human urine (in-vitro measurement) Total activity of beta-emitting radioactive isotopes Radiochemical method Range Procedura operacyjna W-3 wydanie 5 z dnia 06.04.2021 r.","parameters_zh":[{"name":"范围","range":"(0,1 – 10) Bq/dm3"}],"search_zh":"人尿（体外测定） 范围 Procedura operacyjna W-3 wydanie 5 z dnia 06.04.2021 r.","test_object_zh":"人尿（体外测定）"},{"_id":"6a5e8827b979cd801f4834aa","lab_id":"69ad52a3de79e566650fb2e0","country":"PL","accr_number":"AB 567","accr_body":"PCA","test_object":"Mocz człowieka (pomiar in-vitro)","test_object_en":"Human urine (in-vitro measurement)","methodology":"Skuteczna dawka obciążająca (z obliczeń)","methodology_en":"Committed effective dose (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Skuteczna dawka obciążająca (z obliczeń)","reference":"Procedura operacyjna W-3 wydanie 5 z dnia 06.04.2021 r.","norm_bases":["Procedura operacyjna W-3 wydanie 5 z dnia 06.04.2021 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mocz człowieka (pomiar in-vitro) Skuteczna dawka obciążająca (z obliczeń) Procedura operacyjna W-3 wydanie 5 z dnia 06.04.2021 r. Mocz czlowieka (pomiar in-vitro) Skuteczna dawka obciazajaca (z obliczen) Procedura operacyjna W-3 wydanie 5 z dnia 06.04.2021 r.","categories":["other"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Human urine (in-vitro measurement) Committed effective dose (calculated) Procedura operacyjna W-3 wydanie 5 z dnia 06.04.2021 r.","methodology_zh":"待积有效剂量（由计算得出）","search_zh":"人尿（体外测定） 待积有效剂量（由计算得出） Procedura operacyjna W-3 wydanie 5 z dnia 06.04.2021 r.","test_object_zh":"人尿（体外测定）"},{"_id":"6a5e8827b979cd801f4834ab","lab_id":"69ad52a3de79e566650fb2e0","country":"PL","accr_number":"AB 567","accr_body":"PCA","test_object":"Powietrze","test_object_en":"Air","methodology":"Stężenie izotopu radonu 222Rn, Zakres oznaczania dla 30 dni ekspozycji detektora: (55 – 11111) Bq/m3","methodology_en":"Radon isotope 222Rn concentration, Determination range for 30 days of detector exposure: (55 – 11111) Bq/m3","parameters":[],"parameters_en":[],"technique":"Metoda detektorów śladowych","techniques":["Metoda detektorów śladowych"],"technique_en":"Track detector method","computed":[],"computed_en":[],"activity":"Stężenie izotopu radonu 222Rn, Zakres oznaczania dla 30 dni ekspozycji detektora: (55 – 11111) Bq/m3\nMetoda detektorów śladowych","reference":"Procedura operacyjna S-12 wydanie 1 z dnia 01.04.2019 r.","norm_bases":["Procedura operacyjna S-12 wydanie 1 z dnia 01.04.2019 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Powietrze Stężenie izotopu radonu 222Rn, Zakres oznaczania dla 30 dni ekspozycji detektora: (55 – 11111) Bq/m3\nMetoda detektorów śladowych Procedura operacyjna S-12 wydanie 1 z dnia 01.04.2019 r. Powietrze Stezenie izotopu radonu 222Rn, Zakres oznaczania dla 30 dni ekspozycji detektora: (55 – 11111) Bq/m3\nMetoda detektorow sladowych Procedura operacyjna S-12 wydanie 1 z dnia 01.04.2019 r.","categories":["environment"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Air Radon isotope 222Rn concentration, Determination range for 30 days of detector exposure: (55 – 11111) Bq/m3 Track detector method Procedura operacyjna S-12 wydanie 1 z dnia 01.04.2019 r.","search_zh":"空气 径迹探测器法 Procedura operacyjna S-12 wydanie 1 z dnia 01.04.2019 r.","test_object_zh":"空气","technique_zh":"径迹探测器法"},{"_id":"6a5e8827b979cd801f4834ac","lab_id":"69ad52a3de79e566650fb2e0","country":"PL","accr_number":"AB 567","accr_body":"PCA","test_object":"Powietrze","test_object_en":"Air","methodology":"Stężenie izotopu radonu 222Rn, Zakres dla dowolnego czasu ekspozycji detektora: (40 – 8000) kBq*h/m3 podzielony przez czas ekspozycji wyrażony w godzinach","methodology_en":"Radon isotope 222Rn concentration, Range for any detector exposure time: (40 – 8000) kBq*h/m3 divided by the exposure time expressed in hours","parameters":[],"parameters_en":[],"technique":"Metoda detektorów śladowych","techniques":["Metoda detektorów śladowych"],"technique_en":"Track detector method","computed":[],"computed_en":[],"activity":"Stężenie izotopu radonu 222Rn, Zakres dla dowolnego czasu ekspozycji detektora: (40 – 8000) kBq*h/m3 podzielony przez czas ekspozycji wyrażony w godzinach\nMetoda detektorów śladowych","reference":"Procedura operacyjna S-12 wydanie 1 z dnia 01.04.2019 r.","norm_bases":["Procedura operacyjna S-12 wydanie 1 z dnia 01.04.2019 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Powietrze Stężenie izotopu radonu 222Rn, Zakres dla dowolnego czasu ekspozycji detektora: (40 – 8000) kBq*h/m3 podzielony przez czas ekspozycji wyrażony w godzinach\nMetoda detektorów śladowych Procedura operacyjna S-12 wydanie 1 z dnia 01.04.2019 r. Powietrze Stezenie izotopu radonu 222Rn, Zakres dla dowolnego czasu ekspozycji detektora: (40 – 8000) kBq*h/m3 podzielony przez czas ekspozycji wyrazony w godzinach\nMetoda detektorow sladowych Procedura operacyjna S-12 wydanie 1 z dnia 01.04.2019 r.","categories":["environment"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Air Radon isotope 222Rn concentration, Range for any detector exposure time: (40 – 8000) kBq*h/m3 divided by the exposure time expressed in hours Track detector method Procedura operacyjna S-12 wydanie 1 z dnia 01.04.2019 r.","search_zh":"空气 径迹探测器法 Procedura operacyjna S-12 wydanie 1 z dnia 01.04.2019 r.","test_object_zh":"空气","technique_zh":"径迹探测器法"},{"_id":"6a5e8827b979cd801f4834ad","lab_id":"69ad52a3de79e566650fb2e0","country":"PL","accr_number":"AB 567","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie aktywności radionuklidu: 3H (w postaci HTO)","methodology_en":"Activity concentration of radionuclide: 3H (in the form of HTO)","parameters":[{"name":"Zakres","range":"4 Bq/dm3 – 10 MBq/dm3"}],"parameters_en":[{"name":"Range","range":"4 Bq/dm3 – 10 MBq/dm3"}],"technique":"Metoda ciekłej scyntylacji (LSC)","techniques":["Metoda ciekłej scyntylacji (LSC)"],"technique_en":"Liquid scintillation method (LSC)","computed":[],"computed_en":[],"activity":"Stężenie aktywności radionuklidu: 3H (w postaci HTO)\nZakres 4 Bq/dm3 – 10 MBq/dm3\nMetoda ciekłej scyntylacji (LSC)","reference":"Procedura operacyjna S-4 wydanie 6 z dnia 02.08.2021 r.","norm_bases":["Procedura operacyjna S-4 wydanie 6 z dnia 02.08.2021 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie aktywności radionuklidu: 3H (w postaci HTO)\nZakres 4 Bq/dm3 – 10 MBq/dm3\nMetoda ciekłej scyntylacji (LSC) Procedura operacyjna S-4 wydanie 6 z dnia 02.08.2021 r. Woda, scieki Stezenie aktywnosci radionuklidu: 3H (w postaci HTO)\nZakres 4 Bq/dm3 – 10 MBq/dm3\nMetoda cieklej scyntylacji (LSC) Procedura operacyjna S-4 wydanie 6 z dnia 02.08.2021 r.","categories":["water"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Activity concentration of radionuclide: 3H (in the form of HTO) Liquid scintillation method (LSC) Range Procedura operacyjna S-4 wydanie 6 z dnia 02.08.2021 r.","parameters_zh":[{"name":"范围","range":"4 Bq/dm3 – 10 MBq/dm3"}],"search_zh":"水、废水 液体闪烁计数法（LSC） 范围 Procedura operacyjna S-4 wydanie 6 z dnia 02.08.2021 r.","test_object_zh":"水、废水","technique_zh":"液体闪烁计数法（LSC）"},{"_id":"6a5e8827b979cd801f4834ae","lab_id":"69ad52a3de79e566650fb2e0","country":"PL","accr_number":"AB 567","accr_body":"PCA","test_object":"Obiekty i materiały biologiczne przeznaczone do badań 1)","test_object_en":"Biological items and materials intended for testing 1)","methodology":"Stężenie aktywności radionuklidów gamma promieniotwórczych w zakresie energii 20 keV - 2100 keV 2) 3)","methodology_en":"Activity concentration of gamma-emitting radionuclides in the energy range 20 keV - 2100 keV 2) 3)","parameters":[],"parameters_en":[],"technique":"Metoda spektrometrii promieniowania gamma","techniques":["Metoda spektrometrii promieniowania gamma"],"technique_en":"Gamma-ray spectrometry method","computed":[],"computed_en":[],"activity":"Stężenie aktywności radionuklidów gamma promieniotwórczych w zakresie energii 20 keV - 2100 keV 2) 3)\nMetoda spektrometrii promieniowania gamma","reference":"Procedura operacyjna W-1 4)","norm_bases":["Procedura operacyjna W-1 4)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Obiekty i materiały biologiczne przeznaczone do badań 1) Stężenie aktywności radionuklidów gamma promieniotwórczych w zakresie energii 20 keV - 2100 keV 2) 3)\nMetoda spektrometrii promieniowania gamma Procedura operacyjna W-1 4) Obiekty i materialy biologiczne przeznaczone do badan 1) Stezenie aktywnosci radionuklidow gamma promieniotworczych w zakresie energii 20 keV - 2100 keV 2) 3)\nMetoda spektrometrii promieniowania gamma Procedura operacyjna W-1 4)","categories":["materials"],"row_index":21,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Biological items and materials intended for testing 1) Activity concentration of gamma-emitting radionuclides in the energy range 20 keV - 2100 keV 2) 3) Gamma-ray spectrometry method Procedura operacyjna W-1 4)","search_zh":"γ 能谱法 Procedura operacyjna W-1 4)","technique_zh":"γ 能谱法"},{"_id":"6a5e8827b979cd801f4834af","lab_id":"69ad52a3de79e566650fb2e0","country":"PL","accr_number":"AB 567","accr_body":"PCA","test_object":"Obiekty i materiały biologiczne przeznaczone do badań 1)","test_object_en":"Biological items and materials intended for testing 1)","methodology":"Skuteczna dawka obciążająca (z obliczeń)","methodology_en":"Committed effective dose (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Skuteczna dawka obciążająca (z obliczeń)","reference":"Procedura operacyjna W-1 4)","norm_bases":["Procedura operacyjna W-1 4)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Obiekty i materiały biologiczne przeznaczone do badań 1) Skuteczna dawka obciążająca (z obliczeń) Procedura operacyjna W-1 4) Obiekty i materialy biologiczne przeznaczone do badan 1) Skuteczna dawka obciazajaca (z obliczen) Procedura operacyjna W-1 4)","categories":["materials"],"row_index":22,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Biological items and materials intended for testing 1) Committed effective dose (calculated) Procedura operacyjna W-1 4)","methodology_zh":"待积有效剂量（由计算得出）","search_zh":"待积有效剂量（由计算得出） Procedura operacyjna W-1 4)"},{"_id":"6a5e8827b979cd801f4834b0","lab_id":"69ad52a3de79e566650fb2e0","country":"PL","accr_number":"AB 567","accr_body":"PCA","test_object":"Próbki środowiskowe 1)","test_object_en":"Environmental samples 1)","methodology":"Stężenie aktywności radionuklidów gamma promieniotwórczych w zakresie energii 20 keV - 2100 keV 2) 3)","methodology_en":"Activity concentration of gamma-emitting radionuclides in the energy range 20 keV - 2100 keV 2) 3)","parameters":[],"parameters_en":[],"technique":"Metoda spektrometrii promieniowania gamma","techniques":["Metoda spektrometrii promieniowania gamma"],"technique_en":"Gamma-ray spectrometry method","computed":[],"computed_en":[],"activity":"Stężenie aktywności radionuklidów gamma promieniotwórczych w zakresie energii 20 keV - 2100 keV 2) 3)\nMetoda spektrometrii promieniowania gamma","reference":"Procedura operacyjna S-9 4) Procedura operacyjna W-1 4)","norm_bases":["Procedura operacyjna S-9 4) Procedura operacyjna W-1 4)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Próbki środowiskowe 1) Stężenie aktywności radionuklidów gamma promieniotwórczych w zakresie energii 20 keV - 2100 keV 2) 3)\nMetoda spektrometrii promieniowania gamma Procedura operacyjna S-9 4) Procedura operacyjna W-1 4) Probki srodowiskowe 1) Stezenie aktywnosci radionuklidow gamma promieniotworczych w zakresie energii 20 keV - 2100 keV 2) 3)\nMetoda spektrometrii promieniowania gamma Procedura operacyjna S-9 4) Procedura operacyjna W-1 4)","categories":["environment"],"row_index":23,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Environmental samples 1) Activity concentration of gamma-emitting radionuclides in the energy range 20 keV - 2100 keV 2) 3) Gamma-ray spectrometry method Procedura operacyjna S-9 4) Procedura operacyjna W-1 4)","search_zh":"γ 能谱法 Procedura operacyjna S-9 4) Procedura operacyjna W-1 4)","technique_zh":"γ 能谱法"}],"has_pdf":true}