{"lab":{"_id":"69ad52a3de79e566650fb2d4","accr_number":"AB 556","country":"PL","accr_body":"PCA","address":"ul. Domaniewska 41, 02-672 Warszawa, CENTRALNE LABORATORIUM BADAWCZE, Stara Góra, 26-220 Stąporków","categories":["water"],"city":"Stąporków","imported_at":"2026-03-08T10:42:43.265Z","methods_count":53,"name":"HENKEL POLSKA Sp. z o.o.","parse_status":"parsed","parse_version":2,"pdf_files":["AB_556.pdf"],"scope_summary":"","search_text":"henkel polska sp. z o.o. ul. domaniewska 41, 02-672 warszawa, centralne laboratorium badawcze, stara góra, 26-220 stąporków other water materials","status":"active","updated_at":"2026-03-08T14:51:26.573Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:26.573Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20556,podmiot.html","fields_of_testing":[{"codes":"J/5","pl":"Badania mechaniczne materiałów budowlanych","en":"Mechanical tests of building materials"},{"codes":"N/5","pl":"Badania właściwości fizycznych materiałów budowlanych","en":"Tests of physical properties of building materials"}],"issue":{"no":"20","date":"03.10.2023"},"parse_date":"2026-07-20T07:09:42.941Z","parse_source":"script-pdfplumber","map_coord":[51.138015,20.557307],"map_geo":"nominatim-city","has_en":true,"category_counts":{"other":47,"water":3,"construction":2,"materials":1},"category_scores":{"other":41.68,"water":0.17,"construction":0.08,"materials":0.02},"has_zh":true},"methods":[{"_id":"6a5dc9b6f1c10c8ce825cf32","lab_id":"69ad52a3de79e566650fb2d4","country":"PL","accr_number":"AB 556","accr_body":"PCA","test_object":"Kleje do płytek","test_object_en":"Tile adhesives","methodology":"Spływ","methodology_en":"Slip","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Spływ","reference":"PN-EN 12004-2:2017-03","norm_bases":["PN-EN 12004-2:2017-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kleje do płytek Spływ PN-EN 12004-2:2017-03 Kleje do plytek Splyw PN-EN 12004-2:2017-03","categories":["other"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Tile adhesives Slip PN-EN 12004-2:2017-03","search_zh":"瓷砖胶粘剂 流挂 PN-EN 12004-2:2017-03","test_object_zh":"瓷砖胶粘剂","methodology_zh":"流挂"},{"_id":"6a5dc9b6f1c10c8ce825cf33","lab_id":"69ad52a3de79e566650fb2d4","country":"PL","accr_number":"AB 556","accr_body":"PCA","test_object":"Kleje do płytek","test_object_en":"Tile adhesives","methodology":"Czas otwarty","methodology_en":"Open time","parameters":[{"name":"Zakres","range":"(0,1 – 18,0) kN"}],"parameters_en":[{"name":"Range","range":"(0,1 – 18,0) kN"}],"technique":"Metoda pull-off","techniques":["Metoda pull-off"],"technique_en":"Pull-off method","computed":[],"computed_en":[],"activity":"Czas otwarty\nZakres (0,1 – 18,0) kN\nMetoda pull-off","reference":"PN-EN 12004-2:2017-03","norm_bases":["PN-EN 12004-2:2017-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kleje do płytek Czas otwarty\nZakres (0,1 – 18,0) kN\nMetoda pull-off PN-EN 12004-2:2017-03 Kleje do plytek Czas otwarty\nZakres (0,1 – 18,0) kN\nMetoda pull-off PN-EN 12004-2:2017-03","categories":["other"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Tile adhesives Open time Pull-off method Range PN-EN 12004-2:2017-03","parameters_zh":[{"name":"范围","range":"(0,1 – 18,0) kN"}],"search_zh":"瓷砖胶粘剂 开放时间 拉拔法 范围 PN-EN 12004-2:2017-03","technique_zh":"拉拔法","test_object_zh":"瓷砖胶粘剂","methodology_zh":"开放时间"},{"_id":"6a5dc9b6f1c10c8ce825cf34","lab_id":"69ad52a3de79e566650fb2d4","country":"PL","accr_number":"AB 556","accr_body":"PCA","test_object":"Kleje do płytek","test_object_en":"Tile adhesives","methodology":"Przyczepność początkowa Przyczepność po zanurzeniu w wodzie Przyczepność po starzeniu","methodology_en":"Initial adhesion Adhesion after water immersion Adhesion after ageing","parameters":[{"name":"termicznym Przyczepność po cyklu zamrażaniarozmrażania"},{"name":"Zakres","range":"(0,1 – 18,0) kN"}],"parameters_en":[{"name":"thermal Adhesion after a freeze-thaw cycle"},{"name":"Range","range":"(0,1 – 18,0) kN"}],"technique":"Metoda pull-off","techniques":["Metoda pull-off"],"technique_en":"Pull-off method","computed":[],"computed_en":[],"activity":"Przyczepność początkowa Przyczepność po zanurzeniu w wodzie Przyczepność po starzeniu\nZakres:\ntermicznym Przyczepność po cyklu zamrażaniarozmrażania\nZakres (0,1 – 18,0) kN\nMetoda pull-off","reference":"PN-EN 12004-2:2017-03","norm_bases":["PN-EN 12004-2:2017-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kleje do płytek Przyczepność początkowa Przyczepność po zanurzeniu w wodzie Przyczepność po starzeniu\nZakres:\ntermicznym Przyczepność po cyklu zamrażaniarozmrażania\nZakres (0,1 – 18,0) kN\nMetoda pull-off PN-EN 12004-2:2017-03 Kleje do plytek Przyczepnosc poczatkowa Przyczepnosc po zanurzeniu w wodzie Przyczepnosc po starzeniu\nZakres:\ntermicznym Przyczepnosc po cyklu zamrazaniarozmrazania\nZakres (0,1 – 18,0) kN\nMetoda pull-off PN-EN 12004-2:2017-03","categories":["other"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Tile adhesives Initial adhesion Adhesion after water immersion Adhesion after ageing Pull-off method thermal Adhesion after a freeze-thaw cycle Range PN-EN 12004-2:2017-03","parameters_zh":[{"name":"termicznym Przyczepność po cyklu zamrażaniarozmrażania"},{"name":"范围","range":"(0,1 – 18,0) kN"}],"search_zh":"瓷砖胶粘剂 拉拔法 范围 PN-EN 12004-2:2017-03","technique_zh":"拉拔法","test_object_zh":"瓷砖胶粘剂"},{"_id":"6a5dc9b6f1c10c8ce825cf35","lab_id":"69ad52a3de79e566650fb2d4","country":"PL","accr_number":"AB 556","accr_body":"PCA","test_object":"Kleje do płytek","test_object_en":"Tile adhesives","methodology":"Odkształcenie poprzeczne","methodology_en":"Transverse deformation","parameters":[{"name":"Zakres","range":"(0,2 – 40) mm"}],"parameters_en":[{"name":"Range","range":"(0,2 – 40) mm"}],"technique":"Metoda stałego przyrostu obciążenia","techniques":["Metoda stałego przyrostu obciążenia"],"technique_en":"Constant rate of loading method","computed":[],"computed_en":[],"activity":"Odkształcenie poprzeczne\nZakres (0,2 – 40) mm\nMetoda stałego przyrostu obciążenia","reference":"PN-EN 12004-2:2017-03","norm_bases":["PN-EN 12004-2:2017-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kleje do płytek Odkształcenie poprzeczne\nZakres (0,2 – 40) mm\nMetoda stałego przyrostu obciążenia PN-EN 12004-2:2017-03 Kleje do plytek Odksztalcenie poprzeczne\nZakres (0,2 – 40) mm\nMetoda stalego przyrostu obciazenia PN-EN 12004-2:2017-03","categories":["other"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Tile adhesives Transverse deformation Constant rate of loading method Range PN-EN 12004-2:2017-03","parameters_zh":[{"name":"范围","range":"(0,2 – 40) mm"}],"search_zh":"瓷砖胶粘剂 横向变形 等速加载法 范围 PN-EN 12004-2:2017-03","test_object_zh":"瓷砖胶粘剂","methodology_zh":"横向变形","technique_zh":"等速加载法"},{"_id":"6a5dc9b6f1c10c8ce825cf36","lab_id":"69ad52a3de79e566650fb2d4","country":"PL","accr_number":"AB 556","accr_body":"PCA","test_object":"Kleje do płytek","test_object_en":"Tile adhesives","methodology":"Wytrzymałość na ścinanie","methodology_en":"Shear strength","parameters":[{"name":"Zakres","range":"(0,1 – 20) kN"}],"parameters_en":[{"name":"Range","range":"(0,1 – 20) kN"}],"technique":"Metoda stałego przyrostu obciążenia","techniques":["Metoda stałego przyrostu obciążenia"],"technique_en":"Constant rate of loading method","computed":[],"computed_en":[],"activity":"Wytrzymałość na ścinanie\nZakres (0,1 – 20) kN\nMetoda stałego przyrostu obciążenia","reference":"PN-EN 12004-2:2017-03","norm_bases":["PN-EN 12004-2:2017-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kleje do płytek Wytrzymałość na ścinanie\nZakres (0,1 – 20) kN\nMetoda stałego przyrostu obciążenia PN-EN 12004-2:2017-03 Kleje do plytek Wytrzymalosc na scinanie\nZakres (0,1 – 20) kN\nMetoda stalego przyrostu obciazenia PN-EN 12004-2:2017-03","categories":["other"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Tile adhesives Shear strength Constant rate of loading method Range PN-EN 12004-2:2017-03","parameters_zh":[{"name":"范围","range":"(0,1 – 20) kN"}],"search_zh":"瓷砖胶粘剂 抗剪强度 等速加载法 范围 PN-EN 12004-2:2017-03","methodology_zh":"抗剪强度","test_object_zh":"瓷砖胶粘剂","technique_zh":"等速加载法"},{"_id":"6a5dc9b6f1c10c8ce825cf37","lab_id":"69ad52a3de79e566650fb2d4","country":"PL","accr_number":"AB 556","accr_body":"PCA","test_object":"Zaprawy do spoinowania płytek","test_object_en":"Tile grouts","methodology":"Odporność na ścieranie","methodology_en":"Abrasion resistance","parameters":[{"name":"Zakres","range":"do 5000 mm3"}],"parameters_en":[{"name":"Range","range":"do 5000 mm3"}],"technique":"Metoda ścieralności wgłębnej","techniques":["Metoda ścieralności wgłębnej"],"technique_en":"Deep abrasion method","computed":[],"computed_en":[],"activity":"Odporność na ścieranie\nZakres do 5000 mm3\nMetoda ścieralności wgłębnej","reference":"PN-EN 13888-2:2023-02","norm_bases":["PN-EN 13888-2:2023-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zaprawy do spoinowania płytek Odporność na ścieranie\nZakres do 5000 mm3\nMetoda ścieralności wgłębnej PN-EN 13888-2:2023-02 Zaprawy do spoinowania plytek Odpornosc na scieranie\nZakres do 5000 mm3\nMetoda scieralnosci wglebnej PN-EN 13888-2:2023-02","categories":["other"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Tile grouts Abrasion resistance Deep abrasion method Range PN-EN 13888-2:2023-02","parameters_zh":[{"name":"范围","range":"do 5000 mm3"}],"search_zh":"瓷砖填缝砂浆 耐磨性 范围 PN-EN 13888-2:2023-02","methodology_zh":"耐磨性","test_object_zh":"瓷砖填缝砂浆"},{"_id":"6a5dc9b6f1c10c8ce825cf38","lab_id":"69ad52a3de79e566650fb2d4","country":"PL","accr_number":"AB 556","accr_body":"PCA","test_object":"Zaprawy do spoinowania płytek","test_object_en":"Tile grouts","methodology":"Wytrzymałość na zginanie","methodology_en":"Flexural strength","parameters":[{"name":"Zakres","range":"(0,1 – 10) kN"},{"name":"Wytrzymałość na ściskanie"},{"name":"Zakres","range":"(4,0 – 300) kN"}],"parameters_en":[{"name":"Range","range":"(0,1 – 10) kN"},{"name":"Compressive strength"},{"name":"Range","range":"(4,0 – 300) kN"}],"technique":"Metoda stałego przyrostu obciążenia","techniques":["Metoda stałego przyrostu obciążenia"],"technique_en":"Constant rate of loading method","computed":[],"computed_en":[],"activity":"Wytrzymałość na zginanie\nZakres:\nZakres (0,1 – 10) kN\nWytrzymałość na ściskanie\nZakres (4,0 – 300) kN\nMetoda stałego przyrostu obciążenia","reference":"PN-EN 13888-2:2023-02","norm_bases":["PN-EN 13888-2:2023-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zaprawy do spoinowania płytek Wytrzymałość na zginanie\nZakres:\nZakres (0,1 – 10) kN\nWytrzymałość na ściskanie\nZakres (4,0 – 300) kN\nMetoda stałego przyrostu obciążenia PN-EN 13888-2:2023-02 Zaprawy do spoinowania plytek Wytrzymalosc na zginanie\nZakres:\nZakres (0,1 – 10) kN\nWytrzymalosc na sciskanie\nZakres (4,0 – 300) kN\nMetoda stalego przyrostu obciazenia PN-EN 13888-2:2023-02","categories":["other"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Tile grouts Flexural strength Constant rate of loading method Range Compressive strength Range PN-EN 13888-2:2023-02","parameters_zh":[{"name":"范围","range":"(0,1 – 10) kN"},{"name":"抗压强度"},{"name":"范围","range":"(4,0 – 300) kN"}],"search_zh":"瓷砖填缝砂浆 抗弯强度 等速加载法 范围 抗压强度 范围 PN-EN 13888-2:2023-02","methodology_zh":"抗弯强度","technique_zh":"等速加载法","test_object_zh":"瓷砖填缝砂浆"},{"_id":"6a5dc9b6f1c10c8ce825cf39","lab_id":"69ad52a3de79e566650fb2d4","country":"PL","accr_number":"AB 556","accr_body":"PCA","test_object":"Zaprawy do spoinowania płytek","test_object_en":"Tile grouts","methodology":"Skurcz","methodology_en":"Shrinkage","parameters":[{"name":"Zakres","range":"(0 – 12) mm"}],"parameters_en":[{"name":"Range","range":"(0 – 12) mm"}],"technique":"Metoda Graf-Kaufmana","techniques":["Metoda Graf-Kaufmana"],"technique_en":"Graf-Kaufman method","computed":[],"computed_en":[],"activity":"Skurcz\nZakres (0 – 12) mm\nMetoda Graf-Kaufmana","reference":"PN-EN 13888-2:2023-02","norm_bases":["PN-EN 13888-2:2023-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zaprawy do spoinowania płytek Skurcz\nZakres (0 – 12) mm\nMetoda Graf-Kaufmana PN-EN 13888-2:2023-02 Zaprawy do spoinowania plytek Skurcz\nZakres (0 – 12) mm\nMetoda Graf-Kaufmana PN-EN 13888-2:2023-02","categories":["other"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Tile grouts Shrinkage Graf-Kaufman method Range PN-EN 13888-2:2023-02","parameters_zh":[{"name":"范围","range":"(0 – 12) mm"}],"search_zh":"瓷砖填缝砂浆 收缩 格拉夫-考夫曼法 范围 PN-EN 13888-2:2023-02","methodology_zh":"收缩","technique_zh":"格拉夫-考夫曼法","test_object_zh":"瓷砖填缝砂浆"},{"_id":"6a5dc9b6f1c10c8ce825cf3a","lab_id":"69ad52a3de79e566650fb2d4","country":"PL","accr_number":"AB 556","accr_body":"PCA","test_object":"Zaprawy do spoinowania płytek","test_object_en":"Tile grouts","methodology":"Absorbcja wody","methodology_en":"Water absorption","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Absorbcja wody","reference":"PN-EN 13888-2:2023-02","norm_bases":["PN-EN 13888-2:2023-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zaprawy do spoinowania płytek Absorbcja wody PN-EN 13888-2:2023-02 Zaprawy do spoinowania plytek Absorbcja wody PN-EN 13888-2:2023-02","categories":["water"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Tile grouts Water absorption PN-EN 13888-2:2023-02","search_zh":"瓷砖填缝砂浆 PN-EN 13888-2:2023-02","test_object_zh":"瓷砖填缝砂浆"},{"_id":"6a5dc9b6f1c10c8ce825cf3b","lab_id":"69ad52a3de79e566650fb2d4","country":"PL","accr_number":"AB 556","accr_body":"PCA","test_object":"Podkłady podłogowe","test_object_en":"Floor screeds","methodology":"Wytrzymałość na zginanie","methodology_en":"Flexural strength","parameters":[{"name":"Zakres","range":"(0,1 – 10) kN"},{"name":"Wytrzymałość na ściskanie"},{"name":"Zakres","range":"(4,0 – 300) kN"}],"parameters_en":[{"name":"Range","range":"(0,1 – 10) kN"},{"name":"Compressive strength"},{"name":"Range","range":"(4,0 – 300) kN"}],"technique":"Metoda stałego przyrostu obciążenia","techniques":["Metoda stałego przyrostu obciążenia"],"technique_en":"Constant rate of loading method","computed":[],"computed_en":[],"activity":"Wytrzymałość na zginanie\nZakres:\nZakres (0,1 – 10) kN\nWytrzymałość na ściskanie\nZakres (4,0 – 300) kN\nMetoda stałego przyrostu obciążenia","reference":"PN-EN 13892-2:2004","norm_bases":["PN-EN 13892-2:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Podkłady podłogowe Wytrzymałość na zginanie\nZakres:\nZakres (0,1 – 10) kN\nWytrzymałość na ściskanie\nZakres (4,0 – 300) kN\nMetoda stałego przyrostu obciążenia PN-EN 13892-2:2004 Podklady podlogowe Wytrzymalosc na zginanie\nZakres:\nZakres (0,1 – 10) kN\nWytrzymalosc na sciskanie\nZakres (4,0 – 300) kN\nMetoda stalego przyrostu obciazenia PN-EN 13892-2:2004","categories":["other"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Floor screeds Flexural strength Constant rate of loading method Range Compressive strength Range PN-EN 13892-2:2004","parameters_zh":[{"name":"范围","range":"(0,1 – 10) kN"},{"name":"抗压强度"},{"name":"范围","range":"(4,0 – 300) kN"}],"search_zh":"地面找平层 抗弯强度 等速加载法 范围 抗压强度 范围 PN-EN 13892-2:2004","methodology_zh":"抗弯强度","test_object_zh":"地面找平层","technique_zh":"等速加载法"},{"_id":"6a5dc9b6f1c10c8ce825cf3c","lab_id":"69ad52a3de79e566650fb2d4","country":"PL","accr_number":"AB 556","accr_body":"PCA","test_object":"Podkłady podłogowe","test_object_en":"Floor screeds","methodology":"Odporność na ścieranie","methodology_en":"Abrasion resistance","parameters":[{"name":"Zakres","range":"do 350 cm3"}],"parameters_en":[{"name":"Range","range":"do 350 cm3"}],"technique":"Metoda Böhmego","techniques":["Metoda Böhmego"],"technique_en":"Böhme method","computed":[],"computed_en":[],"activity":"Odporność na ścieranie\nZakres do 350 cm3\nMetoda Böhmego","reference":"PN-EN 13892-3:2015-02","norm_bases":["PN-EN 13892-3:2015-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Podkłady podłogowe Odporność na ścieranie\nZakres do 350 cm3\nMetoda Böhmego PN-EN 13892-3:2015-02 Podklady podlogowe Odpornosc na scieranie\nZakres do 350 cm3\nMetoda Bohmego PN-EN 13892-3:2015-02","categories":["other"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Floor screeds Abrasion resistance Böhme method Range PN-EN 13892-3:2015-02","parameters_zh":[{"name":"范围","range":"do 350 cm3"}],"search_zh":"地面找平层 耐磨性 范围 PN-EN 13892-3:2015-02","methodology_zh":"耐磨性","test_object_zh":"地面找平层"},{"_id":"6a5dc9b6f1c10c8ce825cf3d","lab_id":"69ad52a3de79e566650fb2d4","country":"PL","accr_number":"AB 556","accr_body":"PCA","test_object":"Podkłady podłogowe","test_object_en":"Floor screeds","methodology":"Odporność na ścieranie materiałów podkładów podłogowych pokrytych wykładziną podłogową","methodology_en":"Abrasion resistance of floor underlay materials covered with floor covering","parameters":[{"name":"Zakres","range":"(150 – 550) N"}],"parameters_en":[{"name":"Range","range":"(150 – 550) N"}],"technique":"Metoda nacisku toczącego się koła","techniques":["Metoda nacisku toczącego się koła"],"technique_en":"Rolling wheel load method","computed":[],"computed_en":[],"activity":"Odporność na ścieranie materiałów podkładów podłogowych pokrytych wykładziną podłogową\nZakres (150 – 550) N\nMetoda nacisku toczącego się koła","reference":"PN-EN 13892-7:2004","norm_bases":["PN-EN 13892-7:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Podkłady podłogowe Odporność na ścieranie materiałów podkładów podłogowych pokrytych wykładziną podłogową\nZakres (150 – 550) N\nMetoda nacisku toczącego się koła PN-EN 13892-7:2004 Podklady podlogowe Odpornosc na scieranie materialow podkladow podlogowych pokrytych wykladzina podlogowa\nZakres (150 – 550) N\nMetoda nacisku toczacego sie kola PN-EN 13892-7:2004","categories":["materials"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Floor screeds Abrasion resistance of floor underlay materials covered with floor covering Rolling wheel load method Range PN-EN 13892-7:2004","parameters_zh":[{"name":"范围","range":"(150 – 550) N"}],"search_zh":"地面找平层 范围 PN-EN 13892-7:2004","test_object_zh":"地面找平层"},{"_id":"6a5dc9b6f1c10c8ce825cf3e","lab_id":"69ad52a3de79e566650fb2d4","country":"PL","accr_number":"AB 556","accr_body":"PCA","test_object":"Podkłady podłogowe","test_object_en":"Floor screeds","methodology":"Przyczepność","methodology_en":"Adhesion","parameters":[{"name":"Zakres","range":"(0,1 – 18,0) kN"}],"parameters_en":[{"name":"Range","range":"(0,1 – 18,0) kN"}],"technique":"Metoda pull-off","techniques":["Metoda pull-off"],"technique_en":"Pull-off method","computed":[],"computed_en":[],"activity":"Przyczepność\nZakres (0,1 – 18,0) kN\nMetoda pull-off","reference":"PN-EN 13892-8:2004","norm_bases":["PN-EN 13892-8:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Podkłady podłogowe Przyczepność\nZakres (0,1 – 18,0) kN\nMetoda pull-off PN-EN 13892-8:2004 Podklady podlogowe Przyczepnosc\nZakres (0,1 – 18,0) kN\nMetoda pull-off PN-EN 13892-8:2004","categories":["other"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Floor screeds Adhesion Pull-off method Range PN-EN 13892-8:2004","parameters_zh":[{"name":"范围","range":"(0,1 – 18,0) kN"}],"search_zh":"地面找平层 粘结强度 拉拔法 范围 PN-EN 13892-8:2004","technique_zh":"拉拔法","methodology_zh":"粘结强度","test_object_zh":"地面找平层"},{"_id":"6a5dc9b6f1c10c8ce825cf3f","lab_id":"69ad52a3de79e566650fb2d4","country":"PL","accr_number":"AB 556","accr_body":"PCA","test_object":"Podkłady podłogowe","test_object_en":"Floor screeds","methodology":"Skurcz i pęcznienie","methodology_en":"Shrinkage and swelling","parameters":[{"name":"Zakres","range":"(0 – 12) mm"}],"parameters_en":[{"name":"Range","range":"(0 – 12) mm"}],"technique":"Metoda Graf-Kaufmana","techniques":["Metoda Graf-Kaufmana"],"technique_en":"Graf-Kaufman method","computed":[],"computed_en":[],"activity":"Skurcz i pęcznienie\nZakres (0 – 12) mm\nMetoda Graf-Kaufmana","reference":"PN-EN 13454-2:2019-02","norm_bases":["PN-EN 13454-2:2019-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Podkłady podłogowe Skurcz i pęcznienie\nZakres (0 – 12) mm\nMetoda Graf-Kaufmana PN-EN 13454-2:2019-02 Podklady podlogowe Skurcz i pecznienie\nZakres (0 – 12) mm\nMetoda Graf-Kaufmana PN-EN 13454-2:2019-02","categories":["other"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Floor screeds Shrinkage and swelling Graf-Kaufman method Range PN-EN 13454-2:2019-02","parameters_zh":[{"name":"范围","range":"(0 – 12) mm"}],"search_zh":"地面找平层 格拉夫-考夫曼法 范围 PN-EN 13454-2:2019-02","test_object_zh":"地面找平层","technique_zh":"格拉夫-考夫曼法"},{"_id":"6a5dc9b6f1c10c8ce825cf40","lab_id":"69ad52a3de79e566650fb2d4","country":"PL","accr_number":"AB 556","accr_body":"PCA","test_object":"Podkłady podłogowe","test_object_en":"Floor screeds","methodology":"Zmiana wymiarów","methodology_en":"Dimensional change","parameters":[{"name":"Zakres","range":"(0 – 12) mm"}],"parameters_en":[{"name":"Range","range":"(0 – 12) mm"}],"technique":"Metoda Graf-Kaufmana","techniques":["Metoda Graf-Kaufmana"],"technique_en":"Graf-Kaufman method","computed":[],"computed_en":[],"activity":"Zmiana wymiarów\nZakres (0 – 12) mm\nMetoda Graf-Kaufmana","reference":"PN-EN 13872:2005","norm_bases":["PN-EN 13872:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Podkłady podłogowe Zmiana wymiarów\nZakres (0 – 12) mm\nMetoda Graf-Kaufmana PN-EN 13872:2005 Podklady podlogowe Zmiana wymiarow\nZakres (0 – 12) mm\nMetoda Graf-Kaufmana PN-EN 13872:2005","categories":["other"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Floor screeds Dimensional change Graf-Kaufman method Range PN-EN 13872:2005","parameters_zh":[{"name":"范围","range":"(0 – 12) mm"}],"search_zh":"地面找平层 尺寸变化 格拉夫-考夫曼法 范围 PN-EN 13872:2005","test_object_zh":"地面找平层","methodology_zh":"尺寸变化","technique_zh":"格拉夫-考夫曼法"},{"_id":"6a5dc9b6f1c10c8ce825cf41","lab_id":"69ad52a3de79e566650fb2d4","country":"PL","accr_number":"AB 556","accr_body":"PCA","test_object":"Zaprawy do murów","test_object_en":"Masonry mortars","methodology":"Rozkład ziarn","methodology_en":"Grain size distribution","parameters":[{"name":"Zakres","range":"(0,063 – 8,0) mm"}],"parameters_en":[{"name":"Range","range":"(0,063 – 8,0) mm"}],"technique":"Metoda suchego przesiewania; Metoda mokrego przesiewania","techniques":["Metoda suchego przesiewania","Metoda mokrego przesiewania"],"technique_en":"Dry sieving method; Wet sieving method","computed":[],"computed_en":[],"activity":"Rozkład ziarn\nZakres (0,063 – 8,0) mm\nMetoda suchego przesiewania; Metoda mokrego przesiewania","reference":"PN-EN 1015-1:2000+A1:2007","norm_bases":["PN-EN 1015-1:2000+A1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zaprawy do murów Rozkład ziarn\nZakres (0,063 – 8,0) mm\nMetoda suchego przesiewania; Metoda mokrego przesiewania PN-EN 1015-1:2000+A1:2007 Zaprawy do murow Rozklad ziarn\nZakres (0,063 – 8,0) mm\nMetoda suchego przesiewania; Metoda mokrego przesiewania PN-EN 1015-1:2000+A1:2007","categories":["other"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Masonry mortars Grain size distribution Dry sieving method; Wet sieving method Range PN-EN 1015-1:2000+A1:2007","parameters_zh":[{"name":"范围","range":"(0,063 – 8,0) mm"}],"search_zh":"砌筑砂浆 范围 PN-EN 1015-1:2000+A1:2007","test_object_zh":"砌筑砂浆"},{"_id":"6a5dc9b6f1c10c8ce825cf42","lab_id":"69ad52a3de79e566650fb2d4","country":"PL","accr_number":"AB 556","accr_body":"PCA","test_object":"Zaprawy do murów","test_object_en":"Masonry mortars","methodology":"Konsystencja","methodology_en":"Consistency","parameters":[{"name":"Zakres","range":"(100 – 300) mm"}],"parameters_en":[{"name":"Range","range":"(100 – 300) mm"}],"technique":"Metoda stolika rozpływu","techniques":["Metoda stolika rozpływu"],"technique_en":"Flow table method","computed":[],"computed_en":[],"activity":"Konsystencja\nZakres (100 – 300) mm\nMetoda stolika rozpływu","reference":"PN-EN 1015-3:2000+A1:2005 +A2:2007","norm_bases":["PN-EN 1015-3:2000+A1:2005 +A2:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zaprawy do murów Konsystencja\nZakres (100 – 300) mm\nMetoda stolika rozpływu PN-EN 1015-3:2000+A1:2005 +A2:2007 Zaprawy do murow Konsystencja\nZakres (100 – 300) mm\nMetoda stolika rozplywu PN-EN 1015-3:2000+A1:2005 +A2:2007","categories":["other"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Masonry mortars Consistency Flow table method Range PN-EN 1015-3:2000+A1:2005 +A2:2007","methodology_zh":"稠度","parameters_zh":[{"name":"范围","range":"(100 – 300) mm"}],"search_zh":"砌筑砂浆 稠度 跳桌法 范围 PN-EN 1015-3:2000+A1:2005 +A2:2007","test_object_zh":"砌筑砂浆","technique_zh":"跳桌法"},{"_id":"6a5dc9b6f1c10c8ce825cf43","lab_id":"69ad52a3de79e566650fb2d4","country":"PL","accr_number":"AB 556","accr_body":"PCA","test_object":"Zaprawy do murów","test_object_en":"Masonry mortars","methodology":"Gęstość objętościowa","methodology_en":"Bulk density","parameters":[],"parameters_en":[],"technique":"Metoda wibracji; Metoda wstrząsania; Metoda napełniania","techniques":["Metoda wibracji","Metoda wstrząsania","Metoda napełniania"],"technique_en":"Vibration method; Shaking method; Filling method","computed":[],"computed_en":[],"activity":"Gęstość objętościowa\nMetoda wibracji; Metoda wstrząsania; Metoda napełniania","reference":"PN-EN 1015-6:2000+A1:2007","norm_bases":["PN-EN 1015-6:2000+A1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zaprawy do murów Gęstość objętościowa\nMetoda wibracji; Metoda wstrząsania; Metoda napełniania PN-EN 1015-6:2000+A1:2007 Zaprawy do murow Gestosc objetosciowa\nMetoda wibracji; Metoda wstrzasania; Metoda napelniania PN-EN 1015-6:2000+A1:2007","categories":["other"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Masonry mortars Bulk density Vibration method; Shaking method; Filling method PN-EN 1015-6:2000+A1:2007","methodology_zh":"堆积密度","search_zh":"砌筑砂浆 堆积密度 PN-EN 1015-6:2000+A1:2007","test_object_zh":"砌筑砂浆"},{"_id":"6a5dc9b6f1c10c8ce825cf44","lab_id":"69ad52a3de79e566650fb2d4","country":"PL","accr_number":"AB 556","accr_body":"PCA","test_object":"Zaprawy do murów","test_object_en":"Masonry mortars","methodology":"Zawartość powietrza","methodology_en":"Air content","parameters":[{"name":"Zakres","range":"poniżej 20 %"},{"name":"Zakres","range":"powyżej 20%"}],"parameters_en":[{"name":"Range","range":"poniżej 20 %"},{"name":"Range","range":"powyżej 20%"}],"technique":"Metoda A – ciśnieniowa; Metoda B – alkoholowa","techniques":["Metoda A – ciśnieniowa","Metoda B – alkoholowa"],"technique_en":"Method A – pressure; Method B – alcohol","computed":[],"computed_en":[],"activity":"Zawartość powietrza\nZakres:\nZakres poniżej 20 %\nZakres powyżej 20%\nMetoda A – ciśnieniowa; Metoda B – alkoholowa","reference":"PN-EN 1015-7:2000","norm_bases":["PN-EN 1015-7:2000"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zaprawy do murów Zawartość powietrza\nZakres:\nZakres poniżej 20 %\nZakres powyżej 20%\nMetoda A – ciśnieniowa; Metoda B – alkoholowa PN-EN 1015-7:2000 Zaprawy do murow Zawartosc powietrza\nZakres:\nZakres ponizej 20 %\nZakres powyzej 20%\nMetoda A – cisnieniowa; Metoda B – alkoholowa PN-EN 1015-7:2000","categories":["other"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Masonry mortars Air content Method A – pressure; Method B – alcohol Range Range PN-EN 1015-7:2000","methodology_zh":"含气量","parameters_zh":[{"name":"范围","range":"poniżej 20 %"},{"name":"范围","range":"powyżej 20%"}],"search_zh":"砌筑砂浆 含气量 范围 范围 PN-EN 1015-7:2000","test_object_zh":"砌筑砂浆"},{"_id":"6a5dc9b6f1c10c8ce825cf45","lab_id":"69ad52a3de79e566650fb2d4","country":"PL","accr_number":"AB 556","accr_body":"PCA","test_object":"Zaprawy do murów","test_object_en":"Masonry mortars","methodology":"Czas zachowania właściwości roboczych zaprawy ogólnego stosowania","methodology_en":"Open time of general purpose mortar","parameters":[],"parameters_en":[],"technique":"Metoda pręta penetrującego","techniques":["Metoda pręta penetrującego"],"technique_en":"Penetrating rod method","computed":[],"computed_en":[],"activity":"Czas zachowania właściwości roboczych zaprawy ogólnego stosowania\nMetoda pręta penetrującego","reference":"PN-EN 1015-9:2001+A1:2007","norm_bases":["PN-EN 1015-9:2001+A1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zaprawy do murów Czas zachowania właściwości roboczych zaprawy ogólnego stosowania\nMetoda pręta penetrującego PN-EN 1015-9:2001+A1:2007 Zaprawy do murow Czas zachowania wlasciwosci roboczych zaprawy ogolnego stosowania\nMetoda preta penetrujacego PN-EN 1015-9:2001+A1:2007","categories":["other"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Masonry mortars Open time of general purpose mortar Penetrating rod method PN-EN 1015-9:2001+A1:2007","search_zh":"砌筑砂浆 PN-EN 1015-9:2001+A1:2007","test_object_zh":"砌筑砂浆"},{"_id":"6a5dc9b6f1c10c8ce825cf46","lab_id":"69ad52a3de79e566650fb2d4","country":"PL","accr_number":"AB 556","accr_body":"PCA","test_object":"Zaprawy do murów","test_object_en":"Masonry mortars","methodology":"Czas zachowania właściwości roboczych zaprawy cienkowarstwowej","methodology_en":"Open time of thin-layer mortar","parameters":[],"parameters_en":[],"technique":"Metoda stolika rozpływu","techniques":["Metoda stolika rozpływu"],"technique_en":"Flow table method","computed":[],"computed_en":[],"activity":"Czas zachowania właściwości roboczych zaprawy cienkowarstwowej\nMetoda stolika rozpływu","reference":"PN-EN 1015-9:2001+A1:2007","norm_bases":["PN-EN 1015-9:2001+A1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zaprawy do murów Czas zachowania właściwości roboczych zaprawy cienkowarstwowej\nMetoda stolika rozpływu PN-EN 1015-9:2001+A1:2007 Zaprawy do murow Czas zachowania wlasciwosci roboczych zaprawy cienkowarstwowej\nMetoda stolika rozplywu PN-EN 1015-9:2001+A1:2007","categories":["other"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Masonry mortars Open time of thin-layer mortar Flow table method PN-EN 1015-9:2001+A1:2007","search_zh":"砌筑砂浆 跳桌法 PN-EN 1015-9:2001+A1:2007","test_object_zh":"砌筑砂浆","technique_zh":"跳桌法"},{"_id":"6a5dc9b6f1c10c8ce825cf47","lab_id":"69ad52a3de79e566650fb2d4","country":"PL","accr_number":"AB 556","accr_body":"PCA","test_object":"Zaprawy do murów","test_object_en":"Masonry mortars","methodology":"Czas korekty zaprawy cienkowarstwowej","methodology_en":"Correction time of thin-layer mortar","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Czas korekty zaprawy cienkowarstwowej","reference":"PN-EN 1015-9:2001+A1:2007","norm_bases":["PN-EN 1015-9:2001+A1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zaprawy do murów Czas korekty zaprawy cienkowarstwowej PN-EN 1015-9:2001+A1:2007 Zaprawy do murow Czas korekty zaprawy cienkowarstwowej PN-EN 1015-9:2001+A1:2007","categories":["other"],"row_index":21,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Masonry mortars Correction time of thin-layer mortar PN-EN 1015-9:2001+A1:2007","search_zh":"砌筑砂浆 PN-EN 1015-9:2001+A1:2007","test_object_zh":"砌筑砂浆"},{"_id":"6a5dc9b6f1c10c8ce825cf48","lab_id":"69ad52a3de79e566650fb2d4","country":"PL","accr_number":"AB 556","accr_body":"PCA","test_object":"Zaprawy do murów","test_object_en":"Masonry mortars","methodology":"Gęstość wysuszonej stwardniałej zaprawy","methodology_en":"Density of dried hardened mortar","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Gęstość wysuszonej stwardniałej zaprawy","reference":"PN-EN 1015-10:2001+A1:2007","norm_bases":["PN-EN 1015-10:2001+A1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zaprawy do murów Gęstość wysuszonej stwardniałej zaprawy PN-EN 1015-10:2001+A1:2007 Zaprawy do murow Gestosc wysuszonej stwardnialej zaprawy PN-EN 1015-10:2001+A1:2007","categories":["other"],"row_index":22,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Masonry mortars Density of dried hardened mortar PN-EN 1015-10:2001+A1:2007","search_zh":"砌筑砂浆 PN-EN 1015-10:2001+A1:2007","test_object_zh":"砌筑砂浆"},{"_id":"6a5dc9b6f1c10c8ce825cf49","lab_id":"69ad52a3de79e566650fb2d4","country":"PL","accr_number":"AB 556","accr_body":"PCA","test_object":"Zaprawy do murów","test_object_en":"Masonry mortars","methodology":"Wytrzymałość na zginanie","methodology_en":"Flexural strength","parameters":[{"name":"Zakres","range":"(0,1 – 10) kN"}],"parameters_en":[{"name":"Range","range":"(0,1 – 10) kN"}],"technique":"Metoda stałego przyrostu obciążenia","techniques":["Metoda stałego przyrostu obciążenia"],"technique_en":"Constant rate of loading method","computed":[],"computed_en":[],"activity":"Wytrzymałość na zginanie\nZakres (0,1 – 10) kN\nMetoda stałego przyrostu obciążenia","reference":"PN-EN 1015-11:2020-04","norm_bases":["PN-EN 1015-11:2020-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zaprawy do murów Wytrzymałość na zginanie\nZakres (0,1 – 10) kN\nMetoda stałego przyrostu obciążenia PN-EN 1015-11:2020-04 Zaprawy do murow Wytrzymalosc na zginanie\nZakres (0,1 – 10) kN\nMetoda stalego przyrostu obciazenia PN-EN 1015-11:2020-04","categories":["other"],"row_index":23,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Masonry mortars Flexural strength Constant rate of loading method Range PN-EN 1015-11:2020-04","parameters_zh":[{"name":"范围","range":"(0,1 – 10) kN"}],"search_zh":"砌筑砂浆 抗弯强度 等速加载法 范围 PN-EN 1015-11:2020-04","methodology_zh":"抗弯强度","test_object_zh":"砌筑砂浆","technique_zh":"等速加载法"},{"_id":"6a5dc9b6f1c10c8ce825cf4a","lab_id":"69ad52a3de79e566650fb2d4","country":"PL","accr_number":"AB 556","accr_body":"PCA","test_object":"Zaprawy do murów","test_object_en":"Masonry mortars","methodology":"Wytrzymałość na ściskanie","methodology_en":"Compressive strength","parameters":[{"name":"Zakres","range":"(4,0 – 300) kN"}],"parameters_en":[{"name":"Range","range":"(4,0 – 300) kN"}],"technique":"Metoda stałego przyrostu obciążenia","techniques":["Metoda stałego przyrostu obciążenia"],"technique_en":"Constant rate of loading method","computed":[],"computed_en":[],"activity":"Wytrzymałość na ściskanie\nZakres (4,0 – 300) kN\nMetoda stałego przyrostu obciążenia","reference":"PN-EN 1015-11:2020-04","norm_bases":["PN-EN 1015-11:2020-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zaprawy do murów Wytrzymałość na ściskanie\nZakres (4,0 – 300) kN\nMetoda stałego przyrostu obciążenia PN-EN 1015-11:2020-04 Zaprawy do murow Wytrzymalosc na sciskanie\nZakres (4,0 – 300) kN\nMetoda stalego przyrostu obciazenia PN-EN 1015-11:2020-04","categories":["other"],"row_index":24,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Masonry mortars Compressive strength Constant rate of loading method Range PN-EN 1015-11:2020-04","methodology_zh":"抗压强度","parameters_zh":[{"name":"范围","range":"(4,0 – 300) kN"}],"search_zh":"砌筑砂浆 抗压强度 等速加载法 范围 PN-EN 1015-11:2020-04","test_object_zh":"砌筑砂浆","technique_zh":"等速加载法"},{"_id":"6a5dc9b6f1c10c8ce825cf4b","lab_id":"69ad52a3de79e566650fb2d4","country":"PL","accr_number":"AB 556","accr_body":"PCA","test_object":"Zaprawy do murów","test_object_en":"Masonry mortars","methodology":"Przyczepność","methodology_en":"Adhesion","parameters":[{"name":"Zakres","range":"(0,1 – 18,0) kN"}],"parameters_en":[{"name":"Range","range":"(0,1 – 18,0) kN"}],"technique":"Metoda pull-off","techniques":["Metoda pull-off"],"technique_en":"Pull-off method","computed":[],"computed_en":[],"activity":"Przyczepność\nZakres (0,1 – 18,0) kN\nMetoda pull-off","reference":"PN-EN 1015-12:2016-08","norm_bases":["PN-EN 1015-12:2016-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zaprawy do murów Przyczepność\nZakres (0,1 – 18,0) kN\nMetoda pull-off PN-EN 1015-12:2016-08 Zaprawy do murow Przyczepnosc\nZakres (0,1 – 18,0) kN\nMetoda pull-off PN-EN 1015-12:2016-08","categories":["other"],"row_index":25,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Masonry mortars Adhesion Pull-off method Range PN-EN 1015-12:2016-08","parameters_zh":[{"name":"范围","range":"(0,1 – 18,0) kN"}],"search_zh":"砌筑砂浆 粘结强度 拉拔法 范围 PN-EN 1015-12:2016-08","technique_zh":"拉拔法","test_object_zh":"砌筑砂浆","methodology_zh":"粘结强度"},{"_id":"6a5dc9b6f1c10c8ce825cf4c","lab_id":"69ad52a3de79e566650fb2d4","country":"PL","accr_number":"AB 556","accr_body":"PCA","test_object":"Zaprawy do murów","test_object_en":"Masonry mortars","methodology":"Współczynnik absorpcji wody","methodology_en":"Water absorption coefficient","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Współczynnik absorpcji wody","reference":"PN-EN 1015-18:2003","norm_bases":["PN-EN 1015-18:2003"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zaprawy do murów Współczynnik absorpcji wody PN-EN 1015-18:2003 Zaprawy do murow Wspolczynnik absorpcji wody PN-EN 1015-18:2003","categories":["water"],"row_index":26,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Masonry mortars Water absorption coefficient PN-EN 1015-18:2003","search_zh":"砌筑砂浆 PN-EN 1015-18:2003","test_object_zh":"砌筑砂浆"},{"_id":"6a5dc9b6f1c10c8ce825cf4d","lab_id":"69ad52a3de79e566650fb2d4","country":"PL","accr_number":"AB 556","accr_body":"PCA","test_object":"Zaprawy do murów","test_object_en":"Masonry mortars","methodology":"Współczynnik przenoszenia pary wodnej","methodology_en":"Water vapour transmission coefficient","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Współczynnik przenoszenia pary wodnej","reference":"PN-EN 1015-19:2000+A1:2005","norm_bases":["PN-EN 1015-19:2000+A1:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zaprawy do murów Współczynnik przenoszenia pary wodnej PN-EN 1015-19:2000+A1:2005 Zaprawy do murow Wspolczynnik przenoszenia pary wodnej PN-EN 1015-19:2000+A1:2005","categories":["other"],"row_index":27,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Masonry mortars Water vapour transmission coefficient PN-EN 1015-19:2000+A1:2005","search_zh":"砌筑砂浆 PN-EN 1015-19:2000+A1:2005","test_object_zh":"砌筑砂浆"},{"_id":"6a5dc9b6f1c10c8ce825cf4e","lab_id":"69ad52a3de79e566650fb2d4","country":"PL","accr_number":"AB 556","accr_body":"PCA","test_object":"Zaprawy do murów","test_object_en":"Masonry mortars","methodology":"Mrozoodporność","methodology_en":"Frost resistance","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Mrozoodporność","reference":"PN-85/B-04500","norm_bases":["PN-85/B-04500"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zaprawy do murów Mrozoodporność PN-85/B-04500 Zaprawy do murow Mrozoodpornosc PN-85/B-04500","categories":["other"],"row_index":28,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Masonry mortars Frost resistance PN-85/B-04500","methodology_zh":"抗冻性","search_zh":"砌筑砂浆 抗冻性 PN-85/B-04500","test_object_zh":"砌筑砂浆"},{"_id":"6a5dc9b6f1c10c8ce825cf4f","lab_id":"69ad52a3de79e566650fb2d4","country":"PL","accr_number":"AB 556","accr_body":"PCA","test_object":"Kleje","test_object_en":"Adhesives","methodology":"Przyczepność zaprawy klejącej do podłoża","methodology_en":"Adhesion of the adhesive mortar to the substrate","parameters":[{"name":"Zakres","range":"(0,01 – 20) kN"}],"parameters_en":[{"name":"Range","range":"(0,01 – 20) kN"}],"technique":"Metoda pull-off","techniques":["Metoda pull-off"],"technique_en":"Pull-off method","computed":[],"computed_en":[],"activity":"Przyczepność zaprawy klejącej do podłoża\nZakres (0,01 – 20) kN\nMetoda pull-off","reference":"ETAG 004:2013 EAD 040083-00-0404","norm_bases":["ETAG 004:2013 EAD 040083-00-0404"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kleje Przyczepność zaprawy klejącej do podłoża\nZakres (0,01 – 20) kN\nMetoda pull-off ETAG 004:2013 EAD 040083-00-0404 Kleje Przyczepnosc zaprawy klejacej do podloza\nZakres (0,01 – 20) kN\nMetoda pull-off ETAG 004:2013 EAD 040083-00-0404","categories":["other"],"row_index":29,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Adhesives Adhesion of the adhesive mortar to the substrate Pull-off method Range ETAG 004:2013 EAD 040083-00-0404","parameters_zh":[{"name":"范围","range":"(0,01 – 20) kN"}],"search_zh":"胶粘剂 拉拔法 范围 ETAG 004:2013 EAD 040083-00-0404","technique_zh":"拉拔法","test_object_zh":"胶粘剂"},{"_id":"6a5dc9b6f1c10c8ce825cf50","lab_id":"69ad52a3de79e566650fb2d4","country":"PL","accr_number":"AB 556","accr_body":"PCA","test_object":"Kleje","test_object_en":"Adhesives","methodology":"Przyczepność zaprawy klejącej do wyrobu do izolacji cieplnej","methodology_en":"Adhesion of the adhesive mortar to the thermal insulation product","parameters":[{"name":"Zakres","range":"(0,01 – 20) kN"}],"parameters_en":[{"name":"Range","range":"(0,01 – 20) kN"}],"technique":"Metoda pull-off","techniques":["Metoda pull-off"],"technique_en":"Pull-off method","computed":[],"computed_en":[],"activity":"Przyczepność zaprawy klejącej do wyrobu do izolacji cieplnej\nZakres (0,01 – 20) kN\nMetoda pull-off","reference":"ETAG 004:2013 EAD 040083-00-0404","norm_bases":["ETAG 004:2013 EAD 040083-00-0404"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kleje Przyczepność zaprawy klejącej do wyrobu do izolacji cieplnej\nZakres (0,01 – 20) kN\nMetoda pull-off ETAG 004:2013 EAD 040083-00-0404 Kleje Przyczepnosc zaprawy klejacej do wyrobu do izolacji cieplnej\nZakres (0,01 – 20) kN\nMetoda pull-off ETAG 004:2013 EAD 040083-00-0404","categories":["construction"],"row_index":30,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Adhesives Adhesion of the adhesive mortar to the thermal insulation product Pull-off method Range ETAG 004:2013 EAD 040083-00-0404","parameters_zh":[{"name":"范围","range":"(0,01 – 20) kN"}],"search_zh":"胶粘剂 拉拔法 范围 ETAG 004:2013 EAD 040083-00-0404","technique_zh":"拉拔法","test_object_zh":"胶粘剂"},{"_id":"6a5dc9b6f1c10c8ce825cf51","lab_id":"69ad52a3de79e566650fb2d4","country":"PL","accr_number":"AB 556","accr_body":"PCA","test_object":"Kleje","test_object_en":"Adhesives","methodology":"Zawartość popiołu","methodology_en":"Ash content","parameters":[],"parameters_en":[],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość popiołu\nMetoda wagowa","reference":"ETAG 004:2013 EAD 040083-00-0404","norm_bases":["ETAG 004:2013 EAD 040083-00-0404"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kleje Zawartość popiołu\nMetoda wagowa ETAG 004:2013 EAD 040083-00-0404 Kleje Zawartosc popiolu\nMetoda wagowa ETAG 004:2013 EAD 040083-00-0404","categories":["other"],"row_index":31,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Adhesives Ash content Gravimetric method ETAG 004:2013 EAD 040083-00-0404","methodology_zh":"灰分含量","search_zh":"胶粘剂 灰分含量 重量法 ETAG 004:2013 EAD 040083-00-0404","technique_zh":"重量法","test_object_zh":"胶粘剂"},{"_id":"6a5dc9b6f1c10c8ce825cf52","lab_id":"69ad52a3de79e566650fb2d4","country":"PL","accr_number":"AB 556","accr_body":"PCA","test_object":"Kleje","test_object_en":"Adhesives","methodology":"Skład granulometryczny","methodology_en":"Particle size distribution","parameters":[{"name":"Zakres","range":"(0,04 – 4,0) mm"}],"parameters_en":[{"name":"Range","range":"(0,04 – 4,0) mm"}],"technique":"Metoda przesiewania strumieniem powietrza","techniques":["Metoda przesiewania strumieniem powietrza"],"technique_en":"Air jet sieving method","computed":[],"computed_en":[],"activity":"Skład granulometryczny\nZakres (0,04 – 4,0) mm\nMetoda przesiewania strumieniem powietrza","reference":"ETAG 004:2013 EAD 040083-00-0404","norm_bases":["ETAG 004:2013 EAD 040083-00-0404"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kleje Skład granulometryczny\nZakres (0,04 – 4,0) mm\nMetoda przesiewania strumieniem powietrza ETAG 004:2013 EAD 040083-00-0404 Kleje Sklad granulometryczny\nZakres (0,04 – 4,0) mm\nMetoda przesiewania strumieniem powietrza ETAG 004:2013 EAD 040083-00-0404","categories":["other"],"row_index":32,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Adhesives Particle size distribution Air jet sieving method Range ETAG 004:2013 EAD 040083-00-0404","parameters_zh":[{"name":"范围","range":"(0,04 – 4,0) mm"}],"search_zh":"胶粘剂 粒度组成 范围 ETAG 004:2013 EAD 040083-00-0404","methodology_zh":"粒度组成","test_object_zh":"胶粘剂"},{"_id":"6a5dc9b6f1c10c8ce825cf53","lab_id":"69ad52a3de79e566650fb2d4","country":"PL","accr_number":"AB 556","accr_body":"PCA","test_object":"Kleje","test_object_en":"Adhesives","methodology":"Gęstość objętościowa świeżej zaprawy","methodology_en":"Bulk density of fresh mortar","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Gęstość objętościowa świeżej zaprawy","reference":"ETAG 004:2013 EAD 040083-00-0404","norm_bases":["ETAG 004:2013 EAD 040083-00-0404"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kleje Gęstość objętościowa świeżej zaprawy ETAG 004:2013 EAD 040083-00-0404 Kleje Gestosc objetosciowa swiezej zaprawy ETAG 004:2013 EAD 040083-00-0404","categories":["other"],"row_index":33,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Adhesives Bulk density of fresh mortar ETAG 004:2013 EAD 040083-00-0404","search_zh":"胶粘剂 新拌砂浆表观密度 ETAG 004:2013 EAD 040083-00-0404","test_object_zh":"胶粘剂","methodology_zh":"新拌砂浆表观密度"},{"_id":"6a5dc9b6f1c10c8ce825cf54","lab_id":"69ad52a3de79e566650fb2d4","country":"PL","accr_number":"AB 556","accr_body":"PCA","test_object":"Kleje","test_object_en":"Adhesives","methodology":"Gęstość","methodology_en":"Density","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Gęstość","reference":"ETAG 004:2013 EAD 040083-00-0404","norm_bases":["ETAG 004:2013 EAD 040083-00-0404"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kleje Gęstość ETAG 004:2013 EAD 040083-00-0404 Kleje Gestosc ETAG 004:2013 EAD 040083-00-0404","categories":["other"],"row_index":34,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Adhesives Density ETAG 004:2013 EAD 040083-00-0404","methodology_zh":"密度","search_zh":"胶粘剂 密度 ETAG 004:2013 EAD 040083-00-0404","test_object_zh":"胶粘剂"},{"_id":"6a5dc9b6f1c10c8ce825cf55","lab_id":"69ad52a3de79e566650fb2d4","country":"PL","accr_number":"AB 556","accr_body":"PCA","test_object":"Kleje","test_object_en":"Adhesives","methodology":"Statyczny moduł sprężystości, wytrzymałość na rozerwanie i wydłużenie przy zerwaniu","methodology_en":"Static modulus of elasticity, tensile strength and elongation at break","parameters":[{"name":"Zakres","range":"(0,01 – 20) kN"},{"name":"Zakres","range":"(0,2 – 500) mm"}],"parameters_en":[{"name":"Range","range":"(0,01 – 20) kN"},{"name":"Range","range":"(0,2 – 500) mm"}],"technique":"Metoda stałego przyrostu siły","techniques":["Metoda stałego przyrostu siły"],"technique_en":"Constant rate of force increase method","computed":[],"computed_en":[],"activity":"Statyczny moduł sprężystości, wytrzymałość na rozerwanie i wydłużenie przy zerwaniu\nZakres:\nZakres (0,01 – 20) kN\nZakres (0,2 – 500) mm\nMetoda stałego przyrostu siły","reference":"ETAG 004:2013 EAD 040083-00-0404","norm_bases":["ETAG 004:2013 EAD 040083-00-0404"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kleje Statyczny moduł sprężystości, wytrzymałość na rozerwanie i wydłużenie przy zerwaniu\nZakres:\nZakres (0,01 – 20) kN\nZakres (0,2 – 500) mm\nMetoda stałego przyrostu siły ETAG 004:2013 EAD 040083-00-0404 Kleje Statyczny modul sprezystosci, wytrzymalosc na rozerwanie i wydluzenie przy zerwaniu\nZakres:\nZakres (0,01 – 20) kN\nZakres (0,2 – 500) mm\nMetoda stalego przyrostu sily ETAG 004:2013 EAD 040083-00-0404","categories":["other"],"row_index":35,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Adhesives Static modulus of elasticity, tensile strength and elongation at break Constant rate of force increase method Range Range ETAG 004:2013 EAD 040083-00-0404","parameters_zh":[{"name":"范围","range":"(0,01 – 20) kN"},{"name":"范围","range":"(0,2 – 500) mm"}],"search_zh":"胶粘剂 范围 范围 ETAG 004:2013 EAD 040083-00-0404","test_object_zh":"胶粘剂"},{"_id":"6a5dc9b6f1c10c8ce825cf56","lab_id":"69ad52a3de79e566650fb2d4","country":"PL","accr_number":"AB 556","accr_body":"PCA","test_object":"Tynki","test_object_en":"Plasters","methodology":"Gęstość objętościowa świeżej zaprawy","methodology_en":"Bulk density of fresh mortar","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Gęstość objętościowa świeżej zaprawy","reference":"ETAG 004:2013 EAD 040083-00-0404","norm_bases":["ETAG 004:2013 EAD 040083-00-0404"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Tynki Gęstość objętościowa świeżej zaprawy ETAG 004:2013 EAD 040083-00-0404 Tynki Gestosc objetosciowa swiezej zaprawy ETAG 004:2013 EAD 040083-00-0404","categories":["other"],"row_index":36,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Plasters Bulk density of fresh mortar ETAG 004:2013 EAD 040083-00-0404","methodology_zh":"新拌砂浆表观密度","search_zh":"抹面砂浆 新拌砂浆表观密度 ETAG 004:2013 EAD 040083-00-0404","test_object_zh":"抹面砂浆"},{"_id":"6a5dc9b6f1c10c8ce825cf57","lab_id":"69ad52a3de79e566650fb2d4","country":"PL","accr_number":"AB 556","accr_body":"PCA","test_object":"Tynki","test_object_en":"Plasters","methodology":"Gęstość","methodology_en":"Density","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Gęstość","reference":"ETAG 004:2013 EAD 040083-00-0404","norm_bases":["ETAG 004:2013 EAD 040083-00-0404"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Tynki Gęstość ETAG 004:2013 EAD 040083-00-0404 Tynki Gestosc ETAG 004:2013 EAD 040083-00-0404","categories":["other"],"row_index":37,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Plasters Density ETAG 004:2013 EAD 040083-00-0404","methodology_zh":"密度","search_zh":"抹面砂浆 密度 ETAG 004:2013 EAD 040083-00-0404","test_object_zh":"抹面砂浆"},{"_id":"6a5dc9b6f1c10c8ce825cf58","lab_id":"69ad52a3de79e566650fb2d4","country":"PL","accr_number":"AB 556","accr_body":"PCA","test_object":"Tynki","test_object_en":"Plasters","methodology":"Zawartość suchej substancji","methodology_en":"Dry matter content","parameters":[],"parameters_en":[],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość suchej substancji\nMetoda wagowa","reference":"ETAG 004:2013 EAD 040083-00-0404","norm_bases":["ETAG 004:2013 EAD 040083-00-0404"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Tynki Zawartość suchej substancji\nMetoda wagowa ETAG 004:2013 EAD 040083-00-0404 Tynki Zawartosc suchej substancji\nMetoda wagowa ETAG 004:2013 EAD 040083-00-0404","categories":["other"],"row_index":38,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Plasters Dry matter content Gravimetric method ETAG 004:2013 EAD 040083-00-0404","search_zh":"抹面砂浆 干物质含量 重量法 ETAG 004:2013 EAD 040083-00-0404","technique_zh":"重量法","methodology_zh":"干物质含量","test_object_zh":"抹面砂浆"},{"_id":"6a5dc9b6f1c10c8ce825cf59","lab_id":"69ad52a3de79e566650fb2d4","country":"PL","accr_number":"AB 556","accr_body":"PCA","test_object":"Tynki","test_object_en":"Plasters","methodology":"Zawartość popiołu","methodology_en":"Ash content","parameters":[],"parameters_en":[],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość popiołu\nMetoda wagowa","reference":"ETAG 004:2013 EAD 040083-00-0404","norm_bases":["ETAG 004:2013 EAD 040083-00-0404"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Tynki Zawartość popiołu\nMetoda wagowa ETAG 004:2013 EAD 040083-00-0404 Tynki Zawartosc popiolu\nMetoda wagowa ETAG 004:2013 EAD 040083-00-0404","categories":["other"],"row_index":39,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Plasters Ash content Gravimetric method ETAG 004:2013 EAD 040083-00-0404","methodology_zh":"灰分含量","search_zh":"抹面砂浆 灰分含量 重量法 ETAG 004:2013 EAD 040083-00-0404","technique_zh":"重量法","test_object_zh":"抹面砂浆"},{"_id":"6a5dc9b6f1c10c8ce825cf5a","lab_id":"69ad52a3de79e566650fb2d4","country":"PL","accr_number":"AB 556","accr_body":"PCA","test_object":"Tynki","test_object_en":"Plasters","methodology":"Skład granulometryczny","methodology_en":"Particle size distribution","parameters":[{"name":"Zakres","range":"(0,04 – 4,0) mm"}],"parameters_en":[{"name":"Range","range":"(0,04 – 4,0) mm"}],"technique":"Metoda przesiewania strumieniem powietrza; Metoda mokrego przesiewania","techniques":["Metoda przesiewania strumieniem powietrza","Metoda mokrego przesiewania"],"technique_en":"Air jet sieving method; Wet sieving method","computed":[],"computed_en":[],"activity":"Skład granulometryczny\nZakres (0,04 – 4,0) mm\nMetoda przesiewania strumieniem powietrza; Metoda mokrego przesiewania","reference":"ETAG 004:2013 EAD 040083-00-0404","norm_bases":["ETAG 004:2013 EAD 040083-00-0404"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Tynki Skład granulometryczny\nZakres (0,04 – 4,0) mm\nMetoda przesiewania strumieniem powietrza; Metoda mokrego przesiewania ETAG 004:2013 EAD 040083-00-0404 Tynki Sklad granulometryczny\nZakres (0,04 – 4,0) mm\nMetoda przesiewania strumieniem powietrza; Metoda mokrego przesiewania ETAG 004:2013 EAD 040083-00-0404","categories":["other"],"row_index":40,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Plasters Particle size distribution Air jet sieving method; Wet sieving method Range ETAG 004:2013 EAD 040083-00-0404","parameters_zh":[{"name":"范围","range":"(0,04 – 4,0) mm"}],"search_zh":"抹面砂浆 粒度组成 范围 ETAG 004:2013 EAD 040083-00-0404","methodology_zh":"粒度组成","test_object_zh":"抹面砂浆"},{"_id":"6a5dc9b6f1c10c8ce825cf5b","lab_id":"69ad52a3de79e566650fb2d4","country":"PL","accr_number":"AB 556","accr_body":"PCA","test_object":"Siatki zbrojące","test_object_en":"Reinforcing meshes","methodology":"Zawartość popiołu","methodology_en":"Ash content","parameters":[],"parameters_en":[],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość popiołu\nMetoda wagowa","reference":"ETAG 004:2013 EAD 040083-00-0404","norm_bases":["ETAG 004:2013 EAD 040083-00-0404"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Siatki zbrojące Zawartość popiołu\nMetoda wagowa ETAG 004:2013 EAD 040083-00-0404 Siatki zbrojace Zawartosc popiolu\nMetoda wagowa ETAG 004:2013 EAD 040083-00-0404","categories":["other"],"row_index":41,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Reinforcing meshes Ash content Gravimetric method ETAG 004:2013 EAD 040083-00-0404","methodology_zh":"灰分含量","search_zh":"增强网 灰分含量 重量法 ETAG 004:2013 EAD 040083-00-0404","technique_zh":"重量法","test_object_zh":"增强网"},{"_id":"6a5dc9b6f1c10c8ce825cf5c","lab_id":"69ad52a3de79e566650fb2d4","country":"PL","accr_number":"AB 556","accr_body":"PCA","test_object":"Siatki zbrojące","test_object_en":"Reinforcing meshes","methodology":"Wytrzymałość na zerwanie i wydłużenie tkaniny zbrojącej","methodology_en":"Breaking strength and elongation of the reinforcing mesh","parameters":[{"name":"Zakres","range":"(0,01 – 20) kN"}],"parameters_en":[{"name":"Range","range":"(0,01 – 20) kN"}],"technique":"Metoda stałego przyrostu siły","techniques":["Metoda stałego przyrostu siły"],"technique_en":"Constant rate of force increase method","computed":[],"computed_en":[],"activity":"Wytrzymałość na zerwanie i wydłużenie tkaniny zbrojącej\nZakres (0,01 – 20) kN\nMetoda stałego przyrostu siły","reference":"ETAG 004:2013 EAD 040083-00-0404","norm_bases":["ETAG 004:2013 EAD 040083-00-0404"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Siatki zbrojące Wytrzymałość na zerwanie i wydłużenie tkaniny zbrojącej\nZakres (0,01 – 20) kN\nMetoda stałego przyrostu siły ETAG 004:2013 EAD 040083-00-0404 Siatki zbrojace Wytrzymalosc na zerwanie i wydluzenie tkaniny zbrojacej\nZakres (0,01 – 20) kN\nMetoda stalego przyrostu sily ETAG 004:2013 EAD 040083-00-0404","categories":["other"],"row_index":42,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Reinforcing meshes Breaking strength and elongation of the reinforcing mesh Constant rate of force increase method Range ETAG 004:2013 EAD 040083-00-0404","parameters_zh":[{"name":"范围","range":"(0,01 – 20) kN"}],"search_zh":"增强网 范围 ETAG 004:2013 EAD 040083-00-0404","test_object_zh":"增强网"},{"_id":"6a5dc9b6f1c10c8ce825cf5d","lab_id":"69ad52a3de79e566650fb2d4","country":"PL","accr_number":"AB 556","accr_body":"PCA","test_object":"Układy ociepleniowe","test_object_en":"External thermal insulation systems","methodology":"Wodochłonność (badanie podciągania kapilarnego wody)","methodology_en":"Water absorption (capillary water rise test)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wodochłonność (badanie podciągania kapilarnego wody)","reference":"ETAG 004:2013 EAD 040083-00-0404","norm_bases":["ETAG 004:2013 EAD 040083-00-0404"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Układy ociepleniowe Wodochłonność (badanie podciągania kapilarnego wody) ETAG 004:2013 EAD 040083-00-0404 Uklady ociepleniowe Wodochlonnosc (badanie podciagania kapilarnego wody) ETAG 004:2013 EAD 040083-00-0404","categories":["water"],"row_index":43,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"External thermal insulation systems Water absorption (capillary water rise test) ETAG 004:2013 EAD 040083-00-0404","search_zh":"外墙保温系统 ETAG 004:2013 EAD 040083-00-0404","test_object_zh":"外墙保温系统"},{"_id":"6a5dc9b6f1c10c8ce825cf5e","lab_id":"69ad52a3de79e566650fb2d4","country":"PL","accr_number":"AB 556","accr_body":"PCA","test_object":"Układy ociepleniowe","test_object_en":"External thermal insulation systems","methodology":"Wodoszczelność (zachowanie się po cyklach cieplno-wilgotnościowych)","methodology_en":"Watertightness (behaviour after heat-humidity cycles)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wodoszczelność (zachowanie się po cyklach cieplno-wilgotnościowych)","reference":"ETAG 004:2013 EAD 040083-00-0404","norm_bases":["ETAG 004:2013 EAD 040083-00-0404"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Układy ociepleniowe Wodoszczelność (zachowanie się po cyklach cieplno-wilgotnościowych) ETAG 004:2013 EAD 040083-00-0404 Uklady ociepleniowe Wodoszczelnosc (zachowanie sie po cyklach cieplno-wilgotnosciowych) ETAG 004:2013 EAD 040083-00-0404","categories":["other"],"row_index":44,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"External thermal insulation systems Watertightness (behaviour after heat-humidity cycles) ETAG 004:2013 EAD 040083-00-0404","search_zh":"外墙保温系统 ETAG 004:2013 EAD 040083-00-0404","test_object_zh":"外墙保温系统"},{"_id":"6a5dc9b6f1c10c8ce825cf5f","lab_id":"69ad52a3de79e566650fb2d4","country":"PL","accr_number":"AB 556","accr_body":"PCA","test_object":"Układy ociepleniowe","test_object_en":"External thermal insulation systems","methodology":"Wodoszczelność (zachowanie się pod wpływem zamrażania i rozmrażania)","methodology_en":"Watertightness (behaviour under freezing and thawing)","parameters":[],"parameters_en":[],"technique":"Metoda symulacyjna","techniques":["Metoda symulacyjna"],"technique_en":"Simulation method","computed":[],"computed_en":[],"activity":"Wodoszczelność (zachowanie się pod wpływem zamrażania i rozmrażania)\nMetoda symulacyjna","reference":"ETAG 004:2013 EAD 040083-00-0404","norm_bases":["ETAG 004:2013 EAD 040083-00-0404"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Układy ociepleniowe Wodoszczelność (zachowanie się pod wpływem zamrażania i rozmrażania)\nMetoda symulacyjna ETAG 004:2013 EAD 040083-00-0404 Uklady ociepleniowe Wodoszczelnosc (zachowanie sie pod wplywem zamrazania i rozmrazania)\nMetoda symulacyjna ETAG 004:2013 EAD 040083-00-0404","categories":["other"],"row_index":45,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"External thermal insulation systems Watertightness (behaviour under freezing and thawing) Simulation method ETAG 004:2013 EAD 040083-00-0404","search_zh":"外墙保温系统 ETAG 004:2013 EAD 040083-00-0404","test_object_zh":"外墙保温系统"},{"_id":"6a5dc9b6f1c10c8ce825cf60","lab_id":"69ad52a3de79e566650fb2d4","country":"PL","accr_number":"AB 556","accr_body":"PCA","test_object":"Układy ociepleniowe","test_object_en":"External thermal insulation systems","methodology":"Odporność na uderzenie ciałem twardym","methodology_en":"Resistance to hard body impact","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na uderzenie ciałem twardym","reference":"ETAG 004:2013 EAD 040083-00-0404 | PN-B-10027:1993","norm_bases":["ETAG 004:2013 EAD 040083-00-0404","PN-B-10027:1993"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Układy ociepleniowe Odporność na uderzenie ciałem twardym ETAG 004:2013 EAD 040083-00-0404 | PN-B-10027:1993 Uklady ociepleniowe Odpornosc na uderzenie cialem twardym ETAG 004:2013 EAD 040083-00-0404 | PN-B-10027:1993","categories":["other"],"row_index":46,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"External thermal insulation systems Resistance to hard body impact ETAG 004:2013 EAD 040083-00-0404 | PN-B-10027:1993","methodology_zh":"硬物撞击抗力","search_zh":"外墙保温系统 硬物撞击抗力 ETAG 004:2013 EAD 040083-00-0404 | PN-B-10027:1993","test_object_zh":"外墙保温系统"},{"_id":"6a5dc9b6f1c10c8ce825cf61","lab_id":"69ad52a3de79e566650fb2d4","country":"PL","accr_number":"AB 556","accr_body":"PCA","test_object":"Układy ociepleniowe","test_object_en":"External thermal insulation systems","methodology":"Przepuszczalność pary wodnej (opór dyfuzyjny dla pary wodnej)","methodology_en":"Water vapour permeability (water vapour diffusion resistance)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Przepuszczalność pary wodnej (opór dyfuzyjny dla pary wodnej)","reference":"ETAG 004:2013 EAD 040083-00-0404 | PN-EN ISO 7783:2018-11","norm_bases":["ETAG 004:2013 EAD 040083-00-0404","PN-EN ISO 7783:2018-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Układy ociepleniowe Przepuszczalność pary wodnej (opór dyfuzyjny dla pary wodnej) ETAG 004:2013 EAD 040083-00-0404 | PN-EN ISO 7783:2018-11 Uklady ociepleniowe Przepuszczalnosc pary wodnej (opor dyfuzyjny dla pary wodnej) ETAG 004:2013 EAD 040083-00-0404 | PN-EN ISO 7783:2018-11","categories":["other"],"row_index":47,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"External thermal insulation systems Water vapour permeability (water vapour diffusion resistance) ETAG 004:2013 EAD 040083-00-0404 | PN-EN ISO 7783:2018-11","search_zh":"外墙保温系统 水蒸气透过性（水蒸气扩散阻力） ETAG 004:2013 EAD 040083-00-0404 | PN-EN ISO 7783:2018-11","test_object_zh":"外墙保温系统","methodology_zh":"水蒸气透过性（水蒸气扩散阻力）"},{"_id":"6a5dc9b6f1c10c8ce825cf62","lab_id":"69ad52a3de79e566650fb2d4","country":"PL","accr_number":"AB 556","accr_body":"PCA","test_object":"Układy ociepleniowe","test_object_en":"External thermal insulation systems","methodology":"Przyczepność po starzeniu","methodology_en":"Adhesion after ageing","parameters":[{"name":"Zakres","range":"(0,01 – 20) kN"}],"parameters_en":[{"name":"Range","range":"(0,01 – 20) kN"}],"technique":"Metoda pull-off","techniques":["Metoda pull-off"],"technique_en":"Pull-off method","computed":[],"computed_en":[],"activity":"Przyczepność po starzeniu\nZakres (0,01 – 20) kN\nMetoda pull-off","reference":"ETAG 004:2013 EAD 040083-00-0404","norm_bases":["ETAG 004:2013 EAD 040083-00-0404"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Układy ociepleniowe Przyczepność po starzeniu\nZakres (0,01 – 20) kN\nMetoda pull-off ETAG 004:2013 EAD 040083-00-0404 Uklady ociepleniowe Przyczepnosc po starzeniu\nZakres (0,01 – 20) kN\nMetoda pull-off ETAG 004:2013 EAD 040083-00-0404","categories":["other"],"row_index":48,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"External thermal insulation systems Adhesion after ageing Pull-off method Range ETAG 004:2013 EAD 040083-00-0404","parameters_zh":[{"name":"范围","range":"(0,01 – 20) kN"}],"search_zh":"外墙保温系统 拉拔法 范围 ETAG 004:2013 EAD 040083-00-0404","technique_zh":"拉拔法","test_object_zh":"外墙保温系统"},{"_id":"6a5dc9b6f1c10c8ce825cf63","lab_id":"69ad52a3de79e566650fb2d4","country":"PL","accr_number":"AB 556","accr_body":"PCA","test_object":"Układy ociepleniowe","test_object_en":"External thermal insulation systems","methodology":"Przyczepność warstwy zbrojonej tynku do wyrobu izolacji cieplnej","methodology_en":"Adhesion of the reinforced render layer to the thermal insulation product","parameters":[{"name":"Zakres","range":"(0,01 – 20) kN"}],"parameters_en":[{"name":"Range","range":"(0,01 – 20) kN"}],"technique":"Metoda pull-off","techniques":["Metoda pull-off"],"technique_en":"Pull-off method","computed":[],"computed_en":[],"activity":"Przyczepność warstwy zbrojonej tynku do wyrobu izolacji cieplnej\nZakres (0,01 – 20) kN\nMetoda pull-off","reference":"ETAG 004:2013 EAD 040083-00-0404","norm_bases":["ETAG 004:2013 EAD 040083-00-0404"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Układy ociepleniowe Przyczepność warstwy zbrojonej tynku do wyrobu izolacji cieplnej\nZakres (0,01 – 20) kN\nMetoda pull-off ETAG 004:2013 EAD 040083-00-0404 Uklady ociepleniowe Przyczepnosc warstwy zbrojonej tynku do wyrobu izolacji cieplnej\nZakres (0,01 – 20) kN\nMetoda pull-off ETAG 004:2013 EAD 040083-00-0404","categories":["construction"],"row_index":49,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"External thermal insulation systems Adhesion of the reinforced render layer to the thermal insulation product Pull-off method Range ETAG 004:2013 EAD 040083-00-0404","parameters_zh":[{"name":"范围","range":"(0,01 – 20) kN"}],"search_zh":"外墙保温系统 拉拔法 范围 ETAG 004:2013 EAD 040083-00-0404","technique_zh":"拉拔法","test_object_zh":"外墙保温系统"},{"_id":"6a5dc9b6f1c10c8ce825cf64","lab_id":"69ad52a3de79e566650fb2d4","country":"PL","accr_number":"AB 556","accr_body":"PCA","test_object":"Farby, Grunty","test_object_en":"Paints, Primers","methodology":"Gęstość","methodology_en":"Density","parameters":[],"parameters_en":[],"technique":"Metoda piknometryczna","techniques":["Metoda piknometryczna"],"technique_en":"Pycnometric method","computed":[],"computed_en":[],"activity":"Gęstość\nMetoda piknometryczna","reference":"ETAG 004:2013 EAD 040083-00-0404 | PN-EN ISO 2811-1:2016-04","norm_bases":["ETAG 004:2013 EAD 040083-00-0404","PN-EN ISO 2811-1:2016-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Farby, Grunty Gęstość\nMetoda piknometryczna ETAG 004:2013 EAD 040083-00-0404 | PN-EN ISO 2811-1:2016-04 Farby, Grunty Gestosc\nMetoda piknometryczna ETAG 004:2013 EAD 040083-00-0404 | PN-EN ISO 2811-1:2016-04","categories":["other"],"row_index":50,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Paints, Primers Density Pycnometric method ETAG 004:2013 EAD 040083-00-0404 | PN-EN ISO 2811-1:2016-04","methodology_zh":"密度","search_zh":"密度 比重瓶法 ETAG 004:2013 EAD 040083-00-0404 | PN-EN ISO 2811-1:2016-04","technique_zh":"比重瓶法"},{"_id":"6a5dc9b6f1c10c8ce825cf65","lab_id":"69ad52a3de79e566650fb2d4","country":"PL","accr_number":"AB 556","accr_body":"PCA","test_object":"Farby, Grunty","test_object_en":"Paints, Primers","methodology":"Zawartość suchej substancji","methodology_en":"Dry matter content","parameters":[],"parameters_en":[],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość suchej substancji\nMetoda wagowa","reference":"ETAG 004:2013 EAD 040083-00-0404","norm_bases":["ETAG 004:2013 EAD 040083-00-0404"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Farby, Grunty Zawartość suchej substancji\nMetoda wagowa ETAG 004:2013 EAD 040083-00-0404 Farby, Grunty Zawartosc suchej substancji\nMetoda wagowa ETAG 004:2013 EAD 040083-00-0404","categories":["other"],"row_index":51,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Paints, Primers Dry matter content Gravimetric method ETAG 004:2013 EAD 040083-00-0404","search_zh":"干物质含量 重量法 ETAG 004:2013 EAD 040083-00-0404","technique_zh":"重量法","methodology_zh":"干物质含量"},{"_id":"6a5dc9b6f1c10c8ce825cf66","lab_id":"69ad52a3de79e566650fb2d4","country":"PL","accr_number":"AB 556","accr_body":"PCA","test_object":"Farby, Grunty","test_object_en":"Paints, Primers","methodology":"Zawartość popiołu","methodology_en":"Ash content","parameters":[],"parameters_en":[],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość popiołu\nMetoda wagowa","reference":"ETAG 004:2013 EAD 040083-00-0404","norm_bases":["ETAG 004:2013 EAD 040083-00-0404"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Farby, Grunty Zawartość popiołu\nMetoda wagowa ETAG 004:2013 EAD 040083-00-0404 Farby, Grunty Zawartosc popiolu\nMetoda wagowa ETAG 004:2013 EAD 040083-00-0404","categories":["other"],"row_index":52,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Paints, Primers Ash content Gravimetric method ETAG 004:2013 EAD 040083-00-0404","methodology_zh":"灰分含量","search_zh":"灰分含量 重量法 ETAG 004:2013 EAD 040083-00-0404","technique_zh":"重量法"}],"has_pdf":true}