{"lab":{"_id":"69ad52a3de79e566650fb2d2","accr_number":"AB 554","country":"PL","accr_body":"PCA","address":"- GÓRNOŚLĄSKI INSTYTUT TECHNOLOGICZNY, Centrum Badań Materiałów, ul. Karola Miarki 12-14, 44-100 Gliwice","categories":["materials"],"city":"Gliwice","imported_at":"2026-03-08T10:42:43.265Z","methods_count":20,"name":"SIEĆ BADAWCZA ŁUKASIEWICZ","parse_status":"parsed","parse_version":3,"pdf_files":["AB_554.pdf"],"scope_summary":"","search_text":"sieć badawcza łukasiewicz - górnośląski instytut technologiczny, centrum badań materiałów, ul. karola miarki 12-14, 44-100 gliwice materials other","status":"active","updated_at":"2026-03-08T14:51:26.508Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:26.508Z","location":{"type":"Point","coordinates":[18.6714,50.2945]},"email_confidence":"high","email_mx":true,"email_source":"https://git.lukasiewicz.gov.pl/kontakt/","fields_of_testing":[{"codes":"C/8","pl":"Badania chemiczne wyrobów i materiałów konstrukcyjnych","en":"Chemical tests of construction products and materials"},{"codes":"J/8","pl":"Badania mechaniczne i metalograficzne wyrobów i materiałów konstrukcyjnych","en":"Mechanical tests, metallographic tests of construction products and materials"},{"codes":"N/8","pl":"Badania właściwości fizycznych wyrobów i materiałów konstrukcyjnych","en":"Tests of physical properties of construction products and materials"}],"issue":{"no":"21","date":"03.03.2026"},"parse_date":"2026-07-20T07:09:42.912Z","parse_source":"script-pdfplumber","map_coord":[50.294839,18.658329],"map_geo":"nominatim-street","has_en":true,"category_counts":{"materials":14,"other":6},"category_scores":{"materials":9.8,"other":1.8},"has_zh":true},"methods":[{"_id":"6a5dc9b6f1c10c8ce825cf1e","lab_id":"69ad52a3de79e566650fb2d2","country":"PL","accr_number":"AB 554","accr_body":"PCA","test_object":"Wyroby metalowe","test_object_en":"Metal products","methodology":"Granica plastyczności Re, Rp","methodology_en":"Yield strength Re, Rp","parameters":[{"name":"Wytrzymałość na rozciąganie Rm"},{"name":"Wydłużenie A, Agt"},{"name":"Przewężenie Z"},{"name":"Zakres siły F: do 600 kN w temp. pokojowej do 100 kN w temp. podwyższonej","range":"do 900 °C"}],"parameters_en":[{"name":"Tensile strength Rm"},{"name":"Elongation A, Agt"},{"name":"Reduction of area Z"},{"name":"Force range F: up to 600 kN at room temp. up to 100 kN at elevated temp.","range":"do 900 °C"}],"technique":"Metoda: Statyczna próba rozciągania","techniques":["Metoda: Statyczna próba rozciągania"],"technique_en":"Method: Static tensile test","computed":[],"computed_en":[],"activity":"Granica plastyczności Re, Rp\nZakres:\nWytrzymałość na rozciąganie Rm\nWydłużenie A, Agt\nPrzewężenie Z\nZakres siły F: do 600 kN w temp. pokojowej do 100 kN w temp. podwyższonej do 900 °C\nMetoda: Statyczna próba rozciągania","reference":"* | PN-EN ISO 6892-1:2020-05 | PN-EN ISO 6892-2:2018-08","norm_bases":["*","PN-EN ISO 6892-1:2020-05","PN-EN ISO 6892-2:2018-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby metalowe Granica plastyczności Re, Rp\nZakres:\nWytrzymałość na rozciąganie Rm\nWydłużenie A, Agt\nPrzewężenie Z\nZakres siły F: do 600 kN w temp. pokojowej do 100 kN w temp. podwyższonej do 900 °C\nMetoda: Statyczna próba rozciągania * | PN-EN ISO 6892-1:2020-05 | PN-EN ISO 6892-2:2018-08 Wyroby metalowe Granica plastycznosci Re, Rp\nZakres:\nWytrzymalosc na rozciaganie Rm\nWydluzenie A, Agt\nPrzewezenie Z\nZakres sily F: do 600 kN w temp. pokojowej do 100 kN w temp. podwyzszonej do 900 °C\nMetoda: Statyczna proba rozciagania * | PN-EN ISO 6892-1:2020-05 | PN-EN ISO 6892-2:2018-08","categories":["materials"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Metal products Yield strength Re, Rp Method: Static tensile test Tensile strength Rm Elongation A, Agt Reduction of area Z Force range F: up to 600 kN at room temp. up to 100 kN at elevated temp. * | PN-EN ISO 6892-1:2020-05 | PN-EN ISO 6892-2:2018-08","search_zh":"金属制品 抗拉强度 Rm 断面收缩率 Z * | PN-EN ISO 6892-1:2020-05 | PN-EN ISO 6892-2:2018-08","test_object_zh":"金属制品","parameters_zh":[{"name":"抗拉强度 Rm"},{"name":"Wydłużenie A, Agt"},{"name":"断面收缩率 Z"},{"name":"Zakres siły F: do 600 kN w temp. pokojowej do 100 kN w temp. podwyższonej","range":"do 900 °C"}]},{"_id":"6a5dc9b6f1c10c8ce825cf1f","lab_id":"69ad52a3de79e566650fb2d2","country":"PL","accr_number":"AB 554","accr_body":"PCA","test_object":"Wyroby metalowe","test_object_en":"Metal products","methodology":"Energia pochłonięta KV2, KU2","methodology_en":"Absorbed energy KV2, KU2","parameters":[{"name":"Początkowa energia młota 300 J Zakres temperatur","range":"(-80 – 500) °C"},{"name":"i w temp. ciekkłego azotu"}],"parameters_en":[{"name":"Initial hammer energy 300 J Temperature range","range":"(-80 – 500) °C"},{"name":"and at liquid nitrogen temp."}],"technique":"Metoda: Udarność sposobem Charpy’ego","techniques":["Metoda: Udarność sposobem Charpy’ego"],"technique_en":"Method: Impact strength by the Charpy method","computed":[],"computed_en":[],"activity":"Energia pochłonięta KV2, KU2\nZakres:\nPoczątkowa energia młota 300 J Zakres temperatur (-80 – 500) °C\ni w temp. ciekkłego azotu\nMetoda: Udarność sposobem Charpy’ego","reference":"PN-EN ISO 148-1:2017-02 *","norm_bases":["PN-EN ISO 148-1:2017-02 *"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby metalowe Energia pochłonięta KV2, KU2\nZakres:\nPoczątkowa energia młota 300 J Zakres temperatur (-80 – 500) °C\ni w temp. ciekkłego azotu\nMetoda: Udarność sposobem Charpy’ego PN-EN ISO 148-1:2017-02 * Wyroby metalowe Energia pochlonieta KV2, KU2\nZakres:\nPoczatkowa energia mlota 300 J Zakres temperatur (-80 – 500) °C\ni w temp. ciekklego azotu\nMetoda: Udarnosc sposobem Charpy’ego PN-EN ISO 148-1:2017-02 *","categories":["materials"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Metal products Absorbed energy KV2, KU2 Method: Impact strength by the Charpy method Initial hammer energy 300 J Temperature range and at liquid nitrogen temp. PN-EN ISO 148-1:2017-02 *","search_zh":"金属制品 PN-EN ISO 148-1:2017-02 *","test_object_zh":"金属制品"},{"_id":"6a5dc9b6f1c10c8ce825cf20","lab_id":"69ad52a3de79e566650fb2d2","country":"PL","accr_number":"AB 554","accr_body":"PCA","test_object":"Wyroby metalowe","test_object_en":"Metal products","methodology":"Twardość","methodology_en":"Hardness","parameters":[{"name":"Zakres","range":"HV0,1 – HV30"},{"name":"Zakres","range":"(20 – 88) HRA"},{"name":"Zakres","range":"(20 – 100) HRB"},{"name":"Zakres","range":"(20 – 70) HRC"},{"name":"Zakres","range":"do 650 HB"}],"parameters_en":[{"name":"Range","range":"HV0,1 – HV30"},{"name":"Range","range":"(20 – 88) HRA"},{"name":"Range","range":"(20 – 100) HRB"},{"name":"Range","range":"(20 – 70) HRC"},{"name":"Range","range":"do 650 HB"}],"technique":"Metoda: sposobem Vickersa; Metoda: sposobem Rockwella (skala A, B, C); Metoda: sposobem Brinella ( średnica kulki: 2,5; 5; 10 mm)","techniques":["Metoda: sposobem Vickersa","Metoda: sposobem Rockwella (skala A, B, C)","Metoda: sposobem Brinella ( średnica kulki: 2,5; 5; 10 mm)"],"technique_en":"Method: by the Vickers method; Method: by the Rockwell method (scale A, B, C); Method: by the Brinell method ( ball diameter: 2,5; 5; 10 mm)","computed":[],"computed_en":[],"activity":"Twardość\nZakres:\nZakres HV0,1 – HV30\nZakres (20 – 88) HRA\nZakres (20 – 100) HRB\nZakres (20 – 70) HRC\nZakres do 650 HB\nMetoda: sposobem Vickersa; Metoda: sposobem Rockwella (skala A, B, C); Metoda: sposobem Brinella ( średnica kulki: 2,5; 5; 10 mm)","reference":"* | PN-EN ISO 6507-1:2024-04 | PN-EN ISO 6508-1:2024-06 | PN-EN ISO 6506-1:2014-12","norm_bases":["*","PN-EN ISO 6507-1:2024-04","PN-EN ISO 6508-1:2024-06","PN-EN ISO 6506-1:2014-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby metalowe Twardość\nZakres:\nZakres HV0,1 – HV30\nZakres (20 – 88) HRA\nZakres (20 – 100) HRB\nZakres (20 – 70) HRC\nZakres do 650 HB\nMetoda: sposobem Vickersa; Metoda: sposobem Rockwella (skala A, B, C); Metoda: sposobem Brinella ( średnica kulki: 2,5; 5; 10 mm) * | PN-EN ISO 6507-1:2024-04 | PN-EN ISO 6508-1:2024-06 | PN-EN ISO 6506-1:2014-12 Wyroby metalowe Twardosc\nZakres:\nZakres HV0,1 – HV30\nZakres (20 – 88) HRA\nZakres (20 – 100) HRB\nZakres (20 – 70) HRC\nZakres do 650 HB\nMetoda: sposobem Vickersa; Metoda: sposobem Rockwella (skala A, B, C); Metoda: sposobem Brinella ( srednica kulki: 2,5; 5; 10 mm) * | PN-EN ISO 6507-1:2024-04 | PN-EN ISO 6508-1:2024-06 | PN-EN ISO 6506-1:2014-12","categories":["materials"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Metal products Hardness Method: by the Vickers method; Method: by the Rockwell method (scale A, B, C); Method: by the Brinell method ( ball diameter: 2,5; 5; 10 mm) Range Range Range Range Range * | PN-EN ISO 6507-1:2024-04 | PN-EN ISO 6508-1:2024-06 | PN-EN ISO 6506-1:2014-12","parameters_zh":[{"name":"范围","range":"HV0,1 – HV30"},{"name":"范围","range":"(20 – 88) HRA"},{"name":"范围","range":"(20 – 100) HRB"},{"name":"范围","range":"(20 – 70) HRC"},{"name":"范围","range":"do 650 HB"}],"search_zh":"金属制品 硬度 范围 范围 范围 范围 范围 * | PN-EN ISO 6507-1:2024-04 | PN-EN ISO 6508-1:2024-06 | PN-EN ISO 6506-1:2014-12","methodology_zh":"硬度","test_object_zh":"金属制品"},{"_id":"6a5dc9b6f1c10c8ce825cf21","lab_id":"69ad52a3de79e566650fb2d2","country":"PL","accr_number":"AB 554","accr_body":"PCA","test_object":"Wyroby metalowe","test_object_en":"Metal products","methodology":"Stopień zanieczyszczenia stali wtrąceniami niemetalicznymi, Mikrostruktura, Wielkość ziarna, Metalograficzne badania mikroskopowe: metoda mikroskopii świetlnej","methodology_en":"Non-metallic inclusion content in steel, Microstructure, Grain size, Metallographic microscopic examination: light microscopy method","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stopień zanieczyszczenia stali wtrąceniami niemetalicznymi, Mikrostruktura, Wielkość ziarna, Metalograficzne badania mikroskopowe: metoda mikroskopii świetlnej","reference":"* | PN-64/H-04510 | PN-63/H-04504 | PN-66/H-04505 | PN-H-04507-01:1984/Az1:1998 | PN-H-04507-02:1984 | PN-EN ISO 643:2020-07","norm_bases":["*","PN-64/H-04510","PN-63/H-04504","PN-66/H-04505","PN-H-04507-01:1984/Az1:1998","PN-H-04507-02:1984","PN-EN ISO 643:2020-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby metalowe Stopień zanieczyszczenia stali wtrąceniami niemetalicznymi, Mikrostruktura, Wielkość ziarna, Metalograficzne badania mikroskopowe: metoda mikroskopii świetlnej * | PN-64/H-04510 | PN-63/H-04504 | PN-66/H-04505 | PN-H-04507-01:1984/Az1:1998 | PN-H-04507-02:1984 | PN-EN ISO 643:2020-07 Wyroby metalowe Stopien zanieczyszczenia stali wtraceniami niemetalicznymi, Mikrostruktura, Wielkosc ziarna, Metalograficzne badania mikroskopowe: metoda mikroskopii swietlnej * | PN-64/H-04510 | PN-63/H-04504 | PN-66/H-04505 | PN-H-04507-01:1984/Az1:1998 | PN-H-04507-02:1984 | PN-EN ISO 643:2020-07","categories":["materials"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Metal products Non-metallic inclusion content in steel, Microstructure, Grain size, Metallographic microscopic examination: light microscopy method * | PN-64/H-04510 | PN-63/H-04504 | PN-66/H-04505 | PN-H-04507-01:1984/Az1:1998 | PN-H-04507-02:1984 | PN-EN ISO 643:2020-07","search_zh":"金属制品 * | PN-64/H-04510 | PN-63/H-04504 | PN-66/H-04505 | PN-H-04507-01:1984/Az1:1998 | PN-H-04507-02:1984 | PN-EN ISO 643:2020-07","test_object_zh":"金属制品"},{"_id":"6a5dc9b6f1c10c8ce825cf22","lab_id":"69ad52a3de79e566650fb2d2","country":"PL","accr_number":"AB 554","accr_body":"PCA","test_object":"Materiały polikrystaliczne: - lite - proszki","test_object_en":"Polycrystalline materials: - bulk - powders","methodology":"Jakościowa analiza fazowa","methodology_en":"Qualitative phase analysis","parameters":[],"parameters_en":[],"technique":"Metoda dyfrakcji rentgenowskiej","techniques":["Metoda dyfrakcji rentgenowskiej"],"technique_en":"X-ray diffraction method","computed":[],"computed_en":[],"activity":"Jakościowa analiza fazowa\nMetoda dyfrakcji rentgenowskiej","reference":"* Procedura M1-RTG, wyd. 8: 11.2025 | PN-EN 13925-1:2007 z wyłączeniem 7.8 - 7.11 oraz 8","norm_bases":["* Procedura M1-RTG, wyd. 8: 11.2025","PN-EN 13925-1:2007 z wyłączeniem 7.8 - 7.11 oraz 8"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały polikrystaliczne: - lite - proszki Jakościowa analiza fazowa\nMetoda dyfrakcji rentgenowskiej * Procedura M1-RTG, wyd. 8: 11.2025 | PN-EN 13925-1:2007 z wyłączeniem 7.8 - 7.11 oraz 8 Materialy polikrystaliczne: - lite - proszki Jakosciowa analiza fazowa\nMetoda dyfrakcji rentgenowskiej * Procedura M1-RTG, wyd. 8: 11.2025 | PN-EN 13925-1:2007 z wylaczeniem 7.8 - 7.11 oraz 8","categories":["materials"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Polycrystalline materials: - bulk - powders Qualitative phase analysis X-ray diffraction method * Procedura M1-RTG, wyd. 8: 11.2025 | PN-EN 13925-1:2007 z wyłączeniem 7.8 - 7.11 oraz 8","search_zh":"X射线衍射法 * Procedura M1-RTG, wyd. 8: 11.2025 | PN-EN 13925-1:2007 z wyłączeniem 7.8 - 7.11 oraz 8","technique_zh":"X射线衍射法"},{"_id":"6a5dc9b6f1c10c8ce825cf23","lab_id":"69ad52a3de79e566650fb2d2","country":"PL","accr_number":"AB 554","accr_body":"PCA","test_object":"Materiały polikrystaliczne: - lite - proszki","test_object_en":"Polycrystalline materials: - bulk - powders","methodology":"Ilościowa analiza fazowa","methodology_en":"Quantitative phase analysis","parameters":[],"parameters_en":[],"technique":"Metoda dyfrakcji rentegowskiej; Metoda Rietvelda; Metoda Averbacha-Cohena","techniques":["Metoda dyfrakcji rentegowskiej","Metoda Rietvelda","Metoda Averbacha-Cohena"],"technique_en":"X-ray diffraction method; Rietveld method; Averbach-Cohen method","computed":[],"computed_en":[],"activity":"Ilościowa analiza fazowa\nMetoda dyfrakcji rentegowskiej; Metoda Rietvelda; Metoda Averbacha-Cohena","reference":"* Procedura M2-RTG, wyd. 8: 11.2025 | PN-EN 13925-1:2007 z wyłączeniem 7.8 - 7.11 oraz 8","norm_bases":["* Procedura M2-RTG, wyd. 8: 11.2025","PN-EN 13925-1:2007 z wyłączeniem 7.8 - 7.11 oraz 8"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały polikrystaliczne: - lite - proszki Ilościowa analiza fazowa\nMetoda dyfrakcji rentegowskiej; Metoda Rietvelda; Metoda Averbacha-Cohena * Procedura M2-RTG, wyd. 8: 11.2025 | PN-EN 13925-1:2007 z wyłączeniem 7.8 - 7.11 oraz 8 Materialy polikrystaliczne: - lite - proszki Ilosciowa analiza fazowa\nMetoda dyfrakcji rentegowskiej; Metoda Rietvelda; Metoda Averbacha-Cohena * Procedura M2-RTG, wyd. 8: 11.2025 | PN-EN 13925-1:2007 z wylaczeniem 7.8 - 7.11 oraz 8","categories":["materials"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Polycrystalline materials: - bulk - powders Quantitative phase analysis X-ray diffraction method; Rietveld method; Averbach-Cohen method * Procedura M2-RTG, wyd. 8: 11.2025 | PN-EN 13925-1:2007 z wyłączeniem 7.8 - 7.11 oraz 8"},{"_id":"6a5dc9b6f1c10c8ce825cf24","lab_id":"69ad52a3de79e566650fb2d2","country":"PL","accr_number":"AB 554","accr_body":"PCA","test_object":"Rudy żelaza","test_object_en":"Iron ores","methodology":"Zawartość: Fe, Mn, TiO2, CaO, SiO2, Al2O3, MgO, P, K2O, S","methodology_en":"Content of: Fe, Mn, TiO2, CaO, SiO2, Al2O3, MgO, P, K2O, S","parameters":[{"name":"Fe","range":"(35,0 – 71,0) %"},{"name":"Mn","range":"(0,02 – 4,0) %"},{"name":"TiO2","range":"(0,01 – 7,8) %"},{"name":"CaO","range":"(0,01 – 18,0) %"},{"name":"SiO2","range":"(0,15 – 38,5) %"},{"name":"Al2O3","range":"(0,1 – 6,5) %"},{"name":"MgO","range":"(0,06 – 4,0) %"},{"name":"P","range":"(0,005 – 0,6) %"},{"name":"K2O","range":"(0,005 – 0,8) %"},{"name":"S","range":"(0,005 – 0,9) %"}],"parameters_en":[{"name":"Fe","range":"(35,0 – 71,0) %"},{"name":"Mn","range":"(0,02 – 4,0) %"},{"name":"TiO2","range":"(0,01 – 7,8) %"},{"name":"CaO","range":"(0,01 – 18,0) %"},{"name":"SiO2","range":"(0,15 – 38,5) %"},{"name":"Al2O3","range":"(0,1 – 6,5) %"},{"name":"MgO","range":"(0,06 – 4,0) %"},{"name":"P","range":"(0,005 – 0,6) %"},{"name":"K2O","range":"(0,005 – 0,8) %"},{"name":"S","range":"(0,005 – 0,9) %"}],"technique":"Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali(WD-XRF)","techniques":["Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali(WD-XRF)"],"technique_en":"Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF)","computed":[],"computed_en":[],"activity":"Zawartość: Fe, Mn, TiO2, CaO, SiO2, Al2O3, MgO, P, K2O, S\nZakres:\nFe (35,0 – 71,0) %\nMn (0,02 – 4,0) %\nTiO2 (0,01 – 7,8) %\nCaO (0,01 – 18,0) %\nSiO2 (0,15 – 38,5) %\nAl2O3 (0,1 – 6,5) %\nMgO (0,06 – 4,0) %\nP (0,005 – 0,6) %\nK2O (0,005 – 0,8) %\nS (0,005 – 0,9) %\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali(WD-XRF)","reference":"Procedura nr 1/CHEM, wyd. 6: 10.2025","norm_bases":["Procedura nr 1/CHEM, wyd. 6: 10.2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rudy żelaza Zawartość: Fe, Mn, TiO2, CaO, SiO2, Al2O3, MgO, P, K2O, S\nZakres:\nFe (35,0 – 71,0) %\nMn (0,02 – 4,0) %\nTiO2 (0,01 – 7,8) %\nCaO (0,01 – 18,0) %\nSiO2 (0,15 – 38,5) %\nAl2O3 (0,1 – 6,5) %\nMgO (0,06 – 4,0) %\nP (0,005 – 0,6) %\nK2O (0,005 – 0,8) %\nS (0,005 – 0,9) %\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali(WD-XRF) Procedura nr 1/CHEM, wyd. 6: 10.2025 Rudy zelaza Zawartosc: Fe, Mn, TiO2, CaO, SiO2, Al2O3, MgO, P, K2O, S\nZakres:\nFe (35,0 – 71,0) %\nMn (0,02 – 4,0) %\nTiO2 (0,01 – 7,8) %\nCaO (0,01 – 18,0) %\nSiO2 (0,15 – 38,5) %\nAl2O3 (0,1 – 6,5) %\nMgO (0,06 – 4,0) %\nP (0,005 – 0,6) %\nK2O (0,005 – 0,8) %\nS (0,005 – 0,9) %\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersja fali(WD-XRF) Procedura nr 1/CHEM, wyd. 6: 10.2025","categories":["other"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Iron ores Content of: Fe, Mn, TiO2, CaO, SiO2, Al2O3, MgO, P, K2O, S Wavelength dispersive X-ray fluorescence spectrometry method (WD-XRF) Fe Mn TiO2 CaO SiO2 Al2O3 MgO P K2O S Procedura nr 1/CHEM, wyd. 6: 10.2025","parameters_zh":[{"name":"Fe","range":"(35,0 – 71,0) %"},{"name":"Mn","range":"(0,02 – 4,0) %"},{"name":"TiO2","range":"(0,01 – 7,8) %"},{"name":"CaO","range":"(0,01 – 18,0) %"},{"name":"SiO2","range":"(0,15 – 38,5) %"},{"name":"Al2O3","range":"(0,1 – 6,5) %"},{"name":"MgO","range":"(0,06 – 4,0) %"},{"name":"P","range":"(0,005 – 0,6) %"},{"name":"K2O","range":"(0,005 – 0,8) %"},{"name":"S","range":"(0,005 – 0,9) %"}],"search_zh":"Fe Mn TiO2 CaO SiO2 Al2O3 MgO P K2O S Procedura nr 1/CHEM, wyd. 6: 10.2025"},{"_id":"6a5dc9b6f1c10c8ce825cf25","lab_id":"69ad52a3de79e566650fb2d2","country":"PL","accr_number":"AB 554","accr_body":"PCA","test_object":"Rudy żelaza","test_object_en":"Iron ores","methodology":"Zawartość żelaza całkowitego i żelaza (II)","methodology_en":"Content of total iron and iron (II)","parameters":[{"name":"Żelazo całkowite","range":"(30 – 72) %"},{"name":"Żelazo (II) rozpuszczalne w","range":"(1 – 25) %"},{"name":"kwasach"}],"parameters_en":[{"name":"Total iron","range":"(30 – 72) %"},{"name":"Iron(II) soluble in","range":"(1 – 25) %"},{"name":"acids"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Zawartość żelaza całkowitego i żelaza (II)\nZakres:\nŻelazo całkowite (30 – 72) %\nŻelazo (II) rozpuszczalne w (1 – 25) %\nkwasach\nMetoda miareczkowa","reference":"Procedura nr 7/CHEM, wyd. 4: 09.2021","norm_bases":["Procedura nr 7/CHEM, wyd. 4: 09.2021"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rudy żelaza Zawartość żelaza całkowitego i żelaza (II)\nZakres:\nŻelazo całkowite (30 – 72) %\nŻelazo (II) rozpuszczalne w (1 – 25) %\nkwasach\nMetoda miareczkowa Procedura nr 7/CHEM, wyd. 4: 09.2021 Rudy zelaza Zawartosc zelaza calkowitego i zelaza (II)\nZakres:\nZelazo calkowite (30 – 72) %\nZelazo (II) rozpuszczalne w (1 – 25) %\nkwasach\nMetoda miareczkowa Procedura nr 7/CHEM, wyd. 4: 09.2021","categories":["other"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Iron ores Content of total iron and iron (II) Titrimetric method Total iron Iron(II) soluble in acids Procedura nr 7/CHEM, wyd. 4: 09.2021","search_zh":"滴定法 Procedura nr 7/CHEM, wyd. 4: 09.2021","technique_zh":"滴定法"},{"_id":"6a5dc9b6f1c10c8ce825cf26","lab_id":"69ad52a3de79e566650fb2d2","country":"PL","accr_number":"AB 554","accr_body":"PCA","test_object":"Stal chromowa i chromoniklowa","test_object_en":"Chromium and chromium-nickel steel","methodology":"Zawartość C, Mn, Si, P, S, Cr, Ni, Cu, Mo, V, Ti, Nb, Al, W","methodology_en":"C, Mn, Si, P, S, Cr, Ni, Cu, Mo, V, Ti, Nb, Al, W content","parameters":[{"name":"C","range":"(0,014 – 1,08) %"},{"name":"Mn","range":"(0,29 – 2,0) %"},{"name":"Si","range":"(0,30 – 2,5) %"},{"name":"P","range":"(0,010 – 0,040) %"},{"name":"S","range":"(0,004 – 0,035) %"},{"name":"Cr","range":"(8,0 – 28,0) %"},{"name":"Ni","range":"(0,5 – 35,2) %"},{"name":"Cu","range":"(0,05 – 3,5) %"},{"name":"Mo","range":"(0,06 – 3,7) %"},{"name":"V","range":"(0,04 – 0,78) %"},{"name":"Ti","range":"(0,04 – 1,0) %"},{"name":"Nb","range":"(0,07 – 1,1) %"},{"name":"Al","range":"(0,01 – 0,88) %"},{"name":"W","range":"(0,02 – 2,1) %"}],"parameters_en":[{"name":"C","range":"(0,014 – 1,08) %"},{"name":"Mn","range":"(0,29 – 2,0) %"},{"name":"Si","range":"(0,30 – 2,5) %"},{"name":"P","range":"(0,010 – 0,040) %"},{"name":"S","range":"(0,004 – 0,035) %"},{"name":"Cr","range":"(8,0 – 28,0) %"},{"name":"Ni","range":"(0,5 – 35,2) %"},{"name":"Cu","range":"(0,05 – 3,5) %"},{"name":"Mo","range":"(0,06 – 3,7) %"},{"name":"V","range":"(0,04 – 0,78) %"},{"name":"Ti","range":"(0,04 – 1,0) %"},{"name":"Nb","range":"(0,07 – 1,1) %"},{"name":"Al","range":"(0,01 – 0,88) %"},{"name":"W","range":"(0,02 – 2,1) %"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem iskrowym","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem iskrowym"],"technique_en":"Spark excitation atomic emission spectrometry","computed":[],"computed_en":[],"activity":"Zawartość C, Mn, Si, P, S, Cr, Ni, Cu, Mo, V, Ti, Nb, Al, W\nZakres:\nC (0,014 – 1,08) %\nMn (0,29 – 2,0) %\nSi (0,30 – 2,5) %\nP (0,010 – 0,040) %\nS (0,004 – 0,035) %\nCr (8,0 – 28,0) %\nNi (0,5 – 35,2) %\nCu (0,05 – 3,5) %\nMo (0,06 – 3,7) %\nV (0,04 – 0,78) %\nTi (0,04 – 1,0) %\nNb (0,07 – 1,1) %\nAl (0,01 – 0,88) %\nW (0,02 – 2,1) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem iskrowym","reference":"Procedura nr 2a/CHEM, wyd. 7: 10.2025","norm_bases":["Procedura nr 2a/CHEM, wyd. 7: 10.2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stal chromowa i chromoniklowa Zawartość C, Mn, Si, P, S, Cr, Ni, Cu, Mo, V, Ti, Nb, Al, W\nZakres:\nC (0,014 – 1,08) %\nMn (0,29 – 2,0) %\nSi (0,30 – 2,5) %\nP (0,010 – 0,040) %\nS (0,004 – 0,035) %\nCr (8,0 – 28,0) %\nNi (0,5 – 35,2) %\nCu (0,05 – 3,5) %\nMo (0,06 – 3,7) %\nV (0,04 – 0,78) %\nTi (0,04 – 1,0) %\nNb (0,07 – 1,1) %\nAl (0,01 – 0,88) %\nW (0,02 – 2,1) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem iskrowym Procedura nr 2a/CHEM, wyd. 7: 10.2025 Stal chromowa i chromoniklowa Zawartosc C, Mn, Si, P, S, Cr, Ni, Cu, Mo, V, Ti, Nb, Al, W\nZakres:\nC (0,014 – 1,08) %\nMn (0,29 – 2,0) %\nSi (0,30 – 2,5) %\nP (0,010 – 0,040) %\nS (0,004 – 0,035) %\nCr (8,0 – 28,0) %\nNi (0,5 – 35,2) %\nCu (0,05 – 3,5) %\nMo (0,06 – 3,7) %\nV (0,04 – 0,78) %\nTi (0,04 – 1,0) %\nNb (0,07 – 1,1) %\nAl (0,01 – 0,88) %\nW (0,02 – 2,1) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem iskrowym Procedura nr 2a/CHEM, wyd. 7: 10.2025","categories":["materials"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Chromium and chromium-nickel steel C, Mn, Si, P, S, Cr, Ni, Cu, Mo, V, Ti, Nb, Al, W content Spark excitation atomic emission spectrometry C Mn Si P S Cr Ni Cu Mo V Ti Nb Al W Procedura nr 2a/CHEM, wyd. 7: 10.2025","parameters_zh":[{"name":"C","range":"(0,014 – 1,08) %"},{"name":"Mn","range":"(0,29 – 2,0) %"},{"name":"Si","range":"(0,30 – 2,5) %"},{"name":"P","range":"(0,010 – 0,040) %"},{"name":"S","range":"(0,004 – 0,035) %"},{"name":"Cr","range":"(8,0 – 28,0) %"},{"name":"Ni","range":"(0,5 – 35,2) %"},{"name":"Cu","range":"(0,05 – 3,5) %"},{"name":"Mo","range":"(0,06 – 3,7) %"},{"name":"V","range":"(0,04 – 0,78) %"},{"name":"Ti","range":"(0,04 – 1,0) %"},{"name":"Nb","range":"(0,07 – 1,1) %"},{"name":"Al","range":"(0,01 – 0,88) %"},{"name":"W","range":"(0,02 – 2,1) %"}],"search_zh":"火花激发原子发射光谱法 C Mn Si P S Cr Ni Cu Mo V Ti Al Procedura nr 2a/CHEM, wyd. 7: 10.2025","technique_zh":"火花激发原子发射光谱法"},{"_id":"6a5dc9b6f1c10c8ce825cf27","lab_id":"69ad52a3de79e566650fb2d2","country":"PL","accr_number":"AB 554","accr_body":"PCA","test_object":"Stal chromowa i chromoniklowa *)","test_object_en":"Chromium and chromium-nickel steel *)","methodology":"Zawartość: N","methodology_en":"Content of: N","parameters":[{"name":"N","range":"(0,03 – 0,26) %"}],"parameters_en":[{"name":"N","range":"(0,03 – 0,26) %"}],"technique":"Metoda optycznej spektrometrii emisyjnej ze wzbudzeniem iskrowym","techniques":["Metoda optycznej spektrometrii emisyjnej ze wzbudzeniem iskrowym"],"technique_en":"Optical emission spectrometry method with spark excitation","computed":[],"computed_en":[],"activity":"Zawartość: N\nN (0,03 – 0,26) %\nMetoda optycznej spektrometrii emisyjnej ze wzbudzeniem iskrowym","reference":"Procedura nr 2a/CHEM, wyd. 6: 09.2024","norm_bases":["Procedura nr 2a/CHEM, wyd. 6: 09.2024"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stal chromowa i chromoniklowa *) Zawartość: N\nN (0,03 – 0,26) %\nMetoda optycznej spektrometrii emisyjnej ze wzbudzeniem iskrowym Procedura nr 2a/CHEM, wyd. 6: 09.2024 Stal chromowa i chromoniklowa *) Zawartosc: N\nN (0,03 – 0,26) %\nMetoda optycznej spektrometrii emisyjnej ze wzbudzeniem iskrowym Procedura nr 2a/CHEM, wyd. 6: 09.2024","categories":["materials"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Chromium and chromium-nickel steel *) Content of: N Optical emission spectrometry method with spark excitation N Procedura nr 2a/CHEM, wyd. 6: 09.2024"},{"_id":"6a5dc9b6f1c10c8ce825cf28","lab_id":"69ad52a3de79e566650fb2d2","country":"PL","accr_number":"AB 554","accr_body":"PCA","test_object":"Stal węglowa, nisko i średniostopowa","test_object_en":"Carbon, low- and medium-alloy steel","methodology":"Zawartość C, Mn, Si, P, S, Cr, Ni, Cu, Mo, V, Ti, Al, Nb, B, Sn","methodology_en":"C, Mn, Si, P, S, Cr, Ni, Cu, Mo, V, Ti, Al, Nb, B, Sn content","parameters":[{"name":"C","range":"(0,006 – 1,3) %"},{"name":"Mn","range":"(0,05 – 2,0) %"},{"name":"Si","range":"(0,010 – 1,8) %"},{"name":"P","range":"(0,005 – 0,092) %"},{"name":"S","range":"(0,003 – 0,18) %"},{"name":"Cr","range":"(0,01 – 5,2) %"},{"name":"Ni","range":"(0,015 – 4,5) %"},{"name":"Cu","range":"(0,005 – 0,90) %"},{"name":"Mo","range":"(0,005 – 1,5) %"},{"name":"V","range":"(0,003 – 0,8) %"},{"name":"Ti","range":"(0,001 – 0,28) %"},{"name":"Al","range":"(0,003 – 0,55) %"},{"name":"Nb","range":"(0,005 – 0,3) %"},{"name":"B","range":"(0,001 – 0,015) %"},{"name":"Sn","range":"(0,005 – 0,15) %"}],"parameters_en":[{"name":"C","range":"(0,006 – 1,3) %"},{"name":"Mn","range":"(0,05 – 2,0) %"},{"name":"Si","range":"(0,010 – 1,8) %"},{"name":"P","range":"(0,005 – 0,092) %"},{"name":"S","range":"(0,003 – 0,18) %"},{"name":"Cr","range":"(0,01 – 5,2) %"},{"name":"Ni","range":"(0,015 – 4,5) %"},{"name":"Cu","range":"(0,005 – 0,90) %"},{"name":"Mo","range":"(0,005 – 1,5) %"},{"name":"V","range":"(0,003 – 0,8) %"},{"name":"Ti","range":"(0,001 – 0,28) %"},{"name":"Al","range":"(0,003 – 0,55) %"},{"name":"Nb","range":"(0,005 – 0,3) %"},{"name":"B","range":"(0,001 – 0,015) %"},{"name":"Sn","range":"(0,005 – 0,15) %"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem iskrowym","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem iskrowym"],"technique_en":"Spark excitation atomic emission spectrometry","computed":[],"computed_en":[],"activity":"Zawartość C, Mn, Si, P, S, Cr, Ni, Cu, Mo, V, Ti, Al, Nb, B, Sn\nZakres:\nC (0,006 – 1,3) %\nMn (0,05 – 2,0) %\nSi (0,010 – 1,8) %\nP (0,005 – 0,092) %\nS (0,003 – 0,18) %\nCr (0,01 – 5,2) %\nNi (0,015 – 4,5) %\nCu (0,005 – 0,90) %\nMo (0,005 – 1,5) %\nV (0,003 – 0,8) %\nTi (0,001 – 0,28) %\nAl (0,003 – 0,55) %\nNb (0,005 – 0,3) %\nB (0,001 – 0,015) %\nSn (0,005 – 0,15) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem iskrowym","reference":"Procedura nr 3/CHEM, wyd. 7: 10.2025","norm_bases":["Procedura nr 3/CHEM, wyd. 7: 10.2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stal węglowa, nisko i średniostopowa Zawartość C, Mn, Si, P, S, Cr, Ni, Cu, Mo, V, Ti, Al, Nb, B, Sn\nZakres:\nC (0,006 – 1,3) %\nMn (0,05 – 2,0) %\nSi (0,010 – 1,8) %\nP (0,005 – 0,092) %\nS (0,003 – 0,18) %\nCr (0,01 – 5,2) %\nNi (0,015 – 4,5) %\nCu (0,005 – 0,90) %\nMo (0,005 – 1,5) %\nV (0,003 – 0,8) %\nTi (0,001 – 0,28) %\nAl (0,003 – 0,55) %\nNb (0,005 – 0,3) %\nB (0,001 – 0,015) %\nSn (0,005 – 0,15) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem iskrowym Procedura nr 3/CHEM, wyd. 7: 10.2025 Stal weglowa, nisko i sredniostopowa Zawartosc C, Mn, Si, P, S, Cr, Ni, Cu, Mo, V, Ti, Al, Nb, B, Sn\nZakres:\nC (0,006 – 1,3) %\nMn (0,05 – 2,0) %\nSi (0,010 – 1,8) %\nP (0,005 – 0,092) %\nS (0,003 – 0,18) %\nCr (0,01 – 5,2) %\nNi (0,015 – 4,5) %\nCu (0,005 – 0,90) %\nMo (0,005 – 1,5) %\nV (0,003 – 0,8) %\nTi (0,001 – 0,28) %\nAl (0,003 – 0,55) %\nNb (0,005 – 0,3) %\nB (0,001 – 0,015) %\nSn (0,005 – 0,15) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem iskrowym Procedura nr 3/CHEM, wyd. 7: 10.2025","categories":["materials"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Carbon, low- and medium-alloy steel C, Mn, Si, P, S, Cr, Ni, Cu, Mo, V, Ti, Al, Nb, B, Sn content Spark excitation atomic emission spectrometry C Mn Si P S Cr Ni Cu Mo V Ti Al Nb B Sn Procedura nr 3/CHEM, wyd. 7: 10.2025","parameters_zh":[{"name":"C","range":"(0,006 – 1,3) %"},{"name":"Mn","range":"(0,05 – 2,0) %"},{"name":"Si","range":"(0,010 – 1,8) %"},{"name":"P","range":"(0,005 – 0,092) %"},{"name":"S","range":"(0,003 – 0,18) %"},{"name":"Cr","range":"(0,01 – 5,2) %"},{"name":"Ni","range":"(0,015 – 4,5) %"},{"name":"Cu","range":"(0,005 – 0,90) %"},{"name":"Mo","range":"(0,005 – 1,5) %"},{"name":"V","range":"(0,003 – 0,8) %"},{"name":"Ti","range":"(0,001 – 0,28) %"},{"name":"Al","range":"(0,003 – 0,55) %"},{"name":"Nb","range":"(0,005 – 0,3) %"},{"name":"B","range":"(0,001 – 0,015) %"},{"name":"Sn","range":"(0,005 – 0,15) %"}],"search_zh":"火花激发原子发射光谱法 C Mn Si P S Cr Ni Cu Mo V Ti Al B Sn Procedura nr 3/CHEM, wyd. 7: 10.2025","technique_zh":"火花激发原子发射光谱法"},{"_id":"6a5dc9b6f1c10c8ce825cf29","lab_id":"69ad52a3de79e566650fb2d2","country":"PL","accr_number":"AB 554","accr_body":"PCA","test_object":"Stal, żeliwo","test_object_en":"Steel, cast iron","methodology":"Zawartość C, S","methodology_en":"C, S content","parameters":[{"name":"C","range":"(0,006 – 3,9) %"},{"name":"S","range":"(0,0020 – 0,30) %"}],"parameters_en":[{"name":"C","range":"(0,006 – 3,9) %"},{"name":"S","range":"(0,0020 – 0,30) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"technique_en":"High-temperature combustion with IR detection","computed":[],"computed_en":[],"activity":"Zawartość C, S\nZakres:\nC (0,006 – 3,9) %\nS (0,0020 – 0,30) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"Procedura nr 4/CHEM, wyd. 5: 10.2025","norm_bases":["Procedura nr 4/CHEM, wyd. 5: 10.2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stal, żeliwo Zawartość C, S\nZakres:\nC (0,006 – 3,9) %\nS (0,0020 – 0,30) %\nMetoda wysokotemperaturowego spalania z detekcją IR Procedura nr 4/CHEM, wyd. 5: 10.2025 Stal, zeliwo Zawartosc C, S\nZakres:\nC (0,006 – 3,9) %\nS (0,0020 – 0,30) %\nMetoda wysokotemperaturowego spalania z detekcja IR Procedura nr 4/CHEM, wyd. 5: 10.2025","categories":["materials"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Steel, cast iron C, S content High-temperature combustion with IR detection C S Procedura nr 4/CHEM, wyd. 5: 10.2025","search_zh":"高温燃烧红外检测法 C S Procedura nr 4/CHEM, wyd. 5: 10.2025","technique_zh":"高温燃烧红外检测法","parameters_zh":[{"name":"C","range":"(0,006 – 3,9) %"},{"name":"S","range":"(0,0020 – 0,30) %"}]},{"_id":"6a5dc9b6f1c10c8ce825cf2a","lab_id":"69ad52a3de79e566650fb2d2","country":"PL","accr_number":"AB 554","accr_body":"PCA","test_object":"Stal, żeliwo, stopy niklu","test_object_en":"Steel, cast iron, nickel alloys","methodology":"Zawartość N, O","methodology_en":"N, O content","parameters":[{"name":"stal, żeliwo","range":"(0,002 – 0,29) %"},{"name":"N stopy niklu","range":"(0,0004 – 0,012) %"},{"name":"O stopy niklu","range":"(0,0005 – 0,0014) %"}],"parameters_en":[{"name":"steel, cast iron","range":"(0,002 – 0,29) %"},{"name":"N nickel alloys","range":"(0,0004 – 0,012) %"},{"name":"O nickel alloys","range":"(0,0005 – 0,0014) %"}],"technique":"Metoda wysokotemperaturowej ekstrakcji z detekcją (TC) stal, żeliwo (0,0003 – 0,030) %; Metoda wysokotemperaturowej ekstrakcji z detekcją IR","techniques":["Metoda wysokotemperaturowej ekstrakcji z detekcją (TC) stal, żeliwo (0,0003 – 0,030) %","Metoda wysokotemperaturowej ekstrakcji z detekcją IR"],"technique_en":"High-temperature extraction method with (TC) detection steel, cast iron (0,0003 – 0,030) %; High-temperature extraction method with IR detection","computed":[],"computed_en":[],"activity":"Zawartość N, O\nZakres:\nstal, żeliwo (0,002 – 0,29) %\nN stopy niklu (0,0004 – 0,012) %\nO stopy niklu (0,0005 – 0,0014) %\nMetoda wysokotemperaturowej ekstrakcji z detekcją (TC) stal, żeliwo (0,0003 – 0,030) %; Metoda wysokotemperaturowej ekstrakcji z detekcją IR","reference":"Procedura nr 5/CHEM, wyd. 5: 10.2025","norm_bases":["Procedura nr 5/CHEM, wyd. 5: 10.2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stal, żeliwo, stopy niklu Zawartość N, O\nZakres:\nstal, żeliwo (0,002 – 0,29) %\nN stopy niklu (0,0004 – 0,012) %\nO stopy niklu (0,0005 – 0,0014) %\nMetoda wysokotemperaturowej ekstrakcji z detekcją (TC) stal, żeliwo (0,0003 – 0,030) %; Metoda wysokotemperaturowej ekstrakcji z detekcją IR Procedura nr 5/CHEM, wyd. 5: 10.2025 Stal, zeliwo, stopy niklu Zawartosc N, O\nZakres:\nstal, zeliwo (0,002 – 0,29) %\nN stopy niklu (0,0004 – 0,012) %\nO stopy niklu (0,0005 – 0,0014) %\nMetoda wysokotemperaturowej ekstrakcji z detekcja (TC) stal, zeliwo (0,0003 – 0,030) %; Metoda wysokotemperaturowej ekstrakcji z detekcja IR Procedura nr 5/CHEM, wyd. 5: 10.2025","categories":["materials"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Steel, cast iron, nickel alloys N, O content High-temperature extraction method with (TC) detection steel, cast iron (0,0003 – 0,030) %; High-temperature extraction method with IR detection steel, cast iron N nickel alloys O nickel alloys Procedura nr 5/CHEM, wyd. 5: 10.2025"},{"_id":"6a5dc9b6f1c10c8ce825cf2b","lab_id":"69ad52a3de79e566650fb2d2","country":"PL","accr_number":"AB 554","accr_body":"PCA","test_object":"Stalowe, surówka, żeliwo","test_object_en":"Steel, pig iron, cast iron","methodology":"Zawartość: Mn, Cr, Ni, Cu, Mo, V, Ti, Al, W, Si, P","methodology_en":"Content of: Mn, Cr, Ni, Cu, Mo, V, Ti, Al, W, Si, P","parameters":[{"name":"Mn","range":"(0,01 – 4) %"},{"name":"Cr","range":"(0,01 – 25) %"},{"name":"Ni","range":"(0,01 – 25) %"},{"name":"Cu","range":"(0,01 – 4) %"},{"name":"Mo","range":"(0,01 – 4) %"},{"name":"V","range":"(0,01 – 4) %"},{"name":"Ti","range":"(0,001 – 4) %"},{"name":"Al","range":"(0,01 – 4) %"},{"name":"W","range":"(0,01 – 4) %"},{"name":"Si","range":"(0,005 – 5) %"},{"name":"P","range":"(0,005 – 2) %"}],"parameters_en":[{"name":"Mn","range":"(0,01 – 4) %"},{"name":"Cr","range":"(0,01 – 25) %"},{"name":"Ni","range":"(0,01 – 25) %"},{"name":"Cu","range":"(0,01 – 4) %"},{"name":"Mo","range":"(0,01 – 4) %"},{"name":"V","range":"(0,01 – 4) %"},{"name":"Ti","range":"(0,001 – 4) %"},{"name":"Al","range":"(0,01 – 4) %"},{"name":"W","range":"(0,01 – 4) %"},{"name":"Si","range":"(0,005 – 5) %"},{"name":"P","range":"(0,005 – 2) %"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","computed":[],"computed_en":[],"activity":"Zawartość: Mn, Cr, Ni, Cu, Mo, V, Ti, Al, W, Si, P\nZakres:\nMn (0,01 – 4) %\nCr (0,01 – 25) %\nNi (0,01 – 25) %\nCu (0,01 – 4) %\nMo (0,01 – 4) %\nV (0,01 – 4) %\nTi (0,001 – 4) %\nAl (0,01 – 4) %\nW (0,01 – 4) %\nSi (0,005 – 5) %\nP (0,005 – 2) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"Procedura nr 6/CHEM, wyd. 6: 09.2023","norm_bases":["Procedura nr 6/CHEM, wyd. 6: 09.2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stalowe, surówka, żeliwo Zawartość: Mn, Cr, Ni, Cu, Mo, V, Ti, Al, W, Si, P\nZakres:\nMn (0,01 – 4) %\nCr (0,01 – 25) %\nNi (0,01 – 25) %\nCu (0,01 – 4) %\nMo (0,01 – 4) %\nV (0,01 – 4) %\nTi (0,001 – 4) %\nAl (0,01 – 4) %\nW (0,01 – 4) %\nSi (0,005 – 5) %\nP (0,005 – 2) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) Procedura nr 6/CHEM, wyd. 6: 09.2023 Stalowe, surowka, zeliwo Zawartosc: Mn, Cr, Ni, Cu, Mo, V, Ti, Al, W, Si, P\nZakres:\nMn (0,01 – 4) %\nCr (0,01 – 25) %\nNi (0,01 – 25) %\nCu (0,01 – 4) %\nMo (0,01 – 4) %\nV (0,01 – 4) %\nTi (0,001 – 4) %\nAl (0,01 – 4) %\nW (0,01 – 4) %\nSi (0,005 – 5) %\nP (0,005 – 2) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) Procedura nr 6/CHEM, wyd. 6: 09.2023","categories":["materials"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Steel, pig iron, cast iron Content of: Mn, Cr, Ni, Cu, Mo, V, Ti, Al, W, Si, P Inductively coupled plasma optical emission spectrometry (ICP-OES) Mn Cr Ni Cu Mo V Ti Al W Si P Procedura nr 6/CHEM, wyd. 6: 09.2023","parameters_zh":[{"name":"Mn","range":"(0,01 – 4) %"},{"name":"Cr","range":"(0,01 – 25) %"},{"name":"Ni","range":"(0,01 – 25) %"},{"name":"Cu","range":"(0,01 – 4) %"},{"name":"Mo","range":"(0,01 – 4) %"},{"name":"V","range":"(0,01 – 4) %"},{"name":"Ti","range":"(0,001 – 4) %"},{"name":"Al","range":"(0,01 – 4) %"},{"name":"W","range":"(0,01 – 4) %"},{"name":"Si","range":"(0,005 – 5) %"},{"name":"P","range":"(0,005 – 2) %"}],"search_zh":"电感耦合等离子体原子发射光谱法（ICP-OES） Mn Cr Ni Cu Mo V Ti Al Si P Procedura nr 6/CHEM, wyd. 6: 09.2023","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）"},{"_id":"6a5dc9b6f1c10c8ce825cf2c","lab_id":"69ad52a3de79e566650fb2d2","country":"PL","accr_number":"AB 554","accr_body":"PCA","test_object":"Stalowe, surówka, żeliwo","test_object_en":"Steel, pig iron, cast iron","methodology":"Zawartość krzemu","methodology_en":"Silicon content","parameters":[{"name":"Zakres","range":"(0,2 – 5) %"}],"parameters_en":[{"name":"Range","range":"(0,2 – 5) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość krzemu\nZakres (0,2 – 5) %\nMetoda wagowa","reference":"Procedura nr 9/CHEM, wyd. 5: 09.2023","norm_bases":["Procedura nr 9/CHEM, wyd. 5: 09.2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stalowe, surówka, żeliwo Zawartość krzemu\nZakres (0,2 – 5) %\nMetoda wagowa Procedura nr 9/CHEM, wyd. 5: 09.2023 Stalowe, surowka, zeliwo Zawartosc krzemu\nZakres (0,2 – 5) %\nMetoda wagowa Procedura nr 9/CHEM, wyd. 5: 09.2023","categories":["materials"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Steel, pig iron, cast iron Silicon content Gravimetric method Range Procedura nr 9/CHEM, wyd. 5: 09.2023","parameters_zh":[{"name":"范围","range":"(0,2 – 5) %"}],"search_zh":"重量法 范围 Procedura nr 9/CHEM, wyd. 5: 09.2023","technique_zh":"重量法"},{"_id":"6a5dc9b6f1c10c8ce825cf2d","lab_id":"69ad52a3de79e566650fb2d2","country":"PL","accr_number":"AB 554","accr_body":"PCA","test_object":"Stal","test_object_en":"Steel","methodology":"Zawartość H","methodology_en":"H content","parameters":[{"name":"Zakres","range":"(0,7 – 12) ppm"}],"parameters_en":[{"name":"Range","range":"(0,7 – 12) ppm"}],"technique":"Metoda wysokotemperaturowej ekstrakcji z detekcją IR","techniques":["Metoda wysokotemperaturowej ekstrakcji z detekcją IR"],"technique_en":"High-temperature extraction with IR detection","computed":[],"computed_en":[],"activity":"Zawartość H\nZakres (0,7 – 12) ppm\nMetoda wysokotemperaturowej ekstrakcji z detekcją IR","reference":"Procedura nr 15/CHEM, wyd. 5: 11.2025","norm_bases":["Procedura nr 15/CHEM, wyd. 5: 11.2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stal Zawartość H\nZakres (0,7 – 12) ppm\nMetoda wysokotemperaturowej ekstrakcji z detekcją IR Procedura nr 15/CHEM, wyd. 5: 11.2025 Stal Zawartosc H\nZakres (0,7 – 12) ppm\nMetoda wysokotemperaturowej ekstrakcji z detekcja IR Procedura nr 15/CHEM, wyd. 5: 11.2025","categories":["materials"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Steel H content High-temperature extraction with IR detection Range Procedura nr 15/CHEM, wyd. 5: 11.2025","parameters_zh":[{"name":"范围","range":"(0,7 – 12) ppm"}],"search_zh":"钢 范围 Procedura nr 15/CHEM, wyd. 5: 11.2025","test_object_zh":"钢"},{"_id":"6a5dc9b6f1c10c8ce825cf2e","lab_id":"69ad52a3de79e566650fb2d2","country":"PL","accr_number":"AB 554","accr_body":"PCA","test_object":"Stopy niklu","test_object_en":"Nickel alloys","methodology":"Zawartość Mo, Nb, Zr, Re, W, Ta, Cu, Hf, Co, Fe, Mn, Cr, V, Ti, P, Si, Al, B, C","methodology_en":"Mo, Nb, Zr, Re, W, Ta, Cu, Hf, Co, Fe, Mn, Cr, V, Ti, P, Si, Al, B, C content","parameters":[{"name":"Mo","range":"(0,05 – 34,0) %"},{"name":"Nb","range":"(0,005 – 7,5) %"},{"name":"Zr","range":"(0,005 – 0,22) %"},{"name":"Re","range":"(0,01 – 6,2) %"},{"name":"W","range":"(0,02 – 14,8) %"},{"name":"Ta","range":"(0,02 – 12,0) %"},{"name":"Cu","range":"(0,01 – 1,7) %"},{"name":"Hf","range":"(0,01 – 1,5) %"},{"name":"Co","range":"(0,03 – 33,5) %"},{"name":"Fe","range":"(0,02 – 40,5) %"},{"name":"Mn","range":"(0,01 – 1,6) %"},{"name":"Cr","range":"(0,1 – 29,5) %"},{"name":"V","range":"(0,01 – 1,0) %"},{"name":"Ti","range":"(0,005 – 5,3) %"},{"name":"P","range":"(0,002 – 0,056) %"},{"name":"Si","range":"(0,01 – 1,35) %"},{"name":"Al","range":"(0,05 – 6,5) %"}],"parameters_en":[{"name":"Mo","range":"(0,05 – 34,0) %"},{"name":"Nb","range":"(0,005 – 7,5) %"},{"name":"Zr","range":"(0,005 – 0,22) %"},{"name":"Re","range":"(0,01 – 6,2) %"},{"name":"W","range":"(0,02 – 14,8) %"},{"name":"Ta","range":"(0,02 – 12,0) %"},{"name":"Cu","range":"(0,01 – 1,7) %"},{"name":"Hf","range":"(0,01 – 1,5) %"},{"name":"Co","range":"(0,03 – 33,5) %"},{"name":"Fe","range":"(0,02 – 40,5) %"},{"name":"Mn","range":"(0,01 – 1,6) %"},{"name":"Cr","range":"(0,1 – 29,5) %"},{"name":"V","range":"(0,01 – 1,0) %"},{"name":"Ti","range":"(0,005 – 5,3) %"},{"name":"P","range":"(0,002 – 0,056) %"},{"name":"Si","range":"(0,01 – 1,35) %"},{"name":"Al","range":"(0,05 – 6,5) %"}],"technique":"Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF)","techniques":["Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF)"],"technique_en":"Wavelength dispersive X-ray fluorescence spectrometry (WD-XRF)","computed":[],"computed_en":[],"activity":"Zawartość Mo, Nb, Zr, Re, W, Ta, Cu, Hf, Co, Fe, Mn, Cr, V, Ti, P, Si, Al, B, C\nZakres:\nMo (0,05 – 34,0) %\nNb (0,005 – 7,5) %\nZr (0,005 – 0,22) %\nRe (0,01 – 6,2) %\nW (0,02 – 14,8) %\nTa (0,02 – 12,0) %\nCu (0,01 – 1,7) %\nHf (0,01 – 1,5) %\nCo (0,03 – 33,5) %\nFe (0,02 – 40,5) %\nMn (0,01 – 1,6) %\nCr (0,1 – 29,5) %\nV (0,01 – 1,0) %\nTi (0,005 – 5,3) %\nP (0,002 – 0,056) %\nSi (0,01 – 1,35) %\nAl (0,05 – 6,5) %\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF)","reference":"Procedura nr 21/CHEM, wyd. 7: 10.2025","norm_bases":["Procedura nr 21/CHEM, wyd. 7: 10.2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stopy niklu Zawartość Mo, Nb, Zr, Re, W, Ta, Cu, Hf, Co, Fe, Mn, Cr, V, Ti, P, Si, Al, B, C\nZakres:\nMo (0,05 – 34,0) %\nNb (0,005 – 7,5) %\nZr (0,005 – 0,22) %\nRe (0,01 – 6,2) %\nW (0,02 – 14,8) %\nTa (0,02 – 12,0) %\nCu (0,01 – 1,7) %\nHf (0,01 – 1,5) %\nCo (0,03 – 33,5) %\nFe (0,02 – 40,5) %\nMn (0,01 – 1,6) %\nCr (0,1 – 29,5) %\nV (0,01 – 1,0) %\nTi (0,005 – 5,3) %\nP (0,002 – 0,056) %\nSi (0,01 – 1,35) %\nAl (0,05 – 6,5) %\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF) Procedura nr 21/CHEM, wyd. 7: 10.2025 Stopy niklu Zawartosc Mo, Nb, Zr, Re, W, Ta, Cu, Hf, Co, Fe, Mn, Cr, V, Ti, P, Si, Al, B, C\nZakres:\nMo (0,05 – 34,0) %\nNb (0,005 – 7,5) %\nZr (0,005 – 0,22) %\nRe (0,01 – 6,2) %\nW (0,02 – 14,8) %\nTa (0,02 – 12,0) %\nCu (0,01 – 1,7) %\nHf (0,01 – 1,5) %\nCo (0,03 – 33,5) %\nFe (0,02 – 40,5) %\nMn (0,01 – 1,6) %\nCr (0,1 – 29,5) %\nV (0,01 – 1,0) %\nTi (0,005 – 5,3) %\nP (0,002 – 0,056) %\nSi (0,01 – 1,35) %\nAl (0,05 – 6,5) %\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersja fali (WD-XRF) Procedura nr 21/CHEM, wyd. 7: 10.2025","categories":["other"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Nickel alloys Mo, Nb, Zr, Re, W, Ta, Cu, Hf, Co, Fe, Mn, Cr, V, Ti, P, Si, Al, B, C content Wavelength dispersive X-ray fluorescence spectrometry (WD-XRF) Mo Nb Zr Re W Ta Cu Hf Co Fe Mn Cr V Ti P Si Al Procedura nr 21/CHEM, wyd. 7: 10.2025","parameters_zh":[{"name":"Mo","range":"(0,05 – 34,0) %"},{"name":"Nb","range":"(0,005 – 7,5) %"},{"name":"Zr","range":"(0,005 – 0,22) %"},{"name":"Re","range":"(0,01 – 6,2) %"},{"name":"W","range":"(0,02 – 14,8) %"},{"name":"Ta","range":"(0,02 – 12,0) %"},{"name":"Cu","range":"(0,01 – 1,7) %"},{"name":"Hf","range":"(0,01 – 1,5) %"},{"name":"Co","range":"(0,03 – 33,5) %"},{"name":"Fe","range":"(0,02 – 40,5) %"},{"name":"Mn","range":"(0,01 – 1,6) %"},{"name":"Cr","range":"(0,1 – 29,5) %"},{"name":"V","range":"(0,01 – 1,0) %"},{"name":"Ti","range":"(0,005 – 5,3) %"},{"name":"P","range":"(0,002 – 0,056) %"},{"name":"Si","range":"(0,01 – 1,35) %"},{"name":"Al","range":"(0,05 – 6,5) %"}],"search_zh":"波长色散 X 射线荧光光谱法（WD-XRF） Mo Cu Co Fe Mn Cr V Ti P Si Al Procedura nr 21/CHEM, wyd. 7: 10.2025","technique_zh":"波长色散 X 射线荧光光谱法（WD-XRF）"},{"_id":"6a5dc9b6f1c10c8ce825cf2f","lab_id":"69ad52a3de79e566650fb2d2","country":"PL","accr_number":"AB 554","accr_body":"PCA","test_object":"Stopy niklu","test_object_en":"Nickel alloys","methodology":"B (0,002 – 0,016) %, C (0,035 – 0,35) %","methodology_en":"B (0,002 – 0,016) %, C (0,035 – 0,35) %","parameters":[],"parameters_en":[],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem iskrowym","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem iskrowym"],"technique_en":"Spark excitation atomic emission spectrometry","computed":[],"computed_en":[],"activity":"B (0,002 – 0,016) %, C (0,035 – 0,35) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem iskrowym","reference":"Procedura nr 21/CHEM, wyd. 7: 10.2025","norm_bases":["Procedura nr 21/CHEM, wyd. 7: 10.2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stopy niklu B (0,002 – 0,016) %, C (0,035 – 0,35) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem iskrowym Procedura nr 21/CHEM, wyd. 7: 10.2025 Stopy niklu B (0,002 – 0,016) %, C (0,035 – 0,35) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem iskrowym Procedura nr 21/CHEM, wyd. 7: 10.2025","categories":["other"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Nickel alloys B (0,002 – 0,016) %, C (0,035 – 0,35) % Spark excitation atomic emission spectrometry Procedura nr 21/CHEM, wyd. 7: 10.2025","search_zh":"火花激发原子发射光谱法 Procedura nr 21/CHEM, wyd. 7: 10.2025","technique_zh":"火花激发原子发射光谱法"},{"_id":"6a5dc9b6f1c10c8ce825cf30","lab_id":"69ad52a3de79e566650fb2d2","country":"PL","accr_number":"AB 554","accr_body":"PCA","test_object":"Stopy niklu","test_object_en":"Nickel alloys","methodology":"Zawartość Pb, Bi, Sn, Se, Ag, Tl, Te","methodology_en":"Content of Pb, Bi, Sn, Se, Ag, Tl, Te","parameters":[{"name":"Pb","range":"(0,5 – 10) ppm"},{"name":"Bi","range":"(0,3 –10) ppm"},{"name":"Sn","range":"(1,0 – 6) ppm"},{"name":"Se","range":"(0,5 – 10) ppm"},{"name":"Ag","range":"(0,5 – 4) ppm"},{"name":"Tl","range":"(0,5 – 8) ppm"},{"name":"Te","range":"(0,5 – 10) ppm"}],"parameters_en":[{"name":"Pb","range":"(0,5 – 10) ppm"},{"name":"Bi","range":"(0,3 –10) ppm"},{"name":"Sn","range":"(1,0 – 6) ppm"},{"name":"Se","range":"(0,5 – 10) ppm"},{"name":"Ag","range":"(0,5 – 4) ppm"},{"name":"Tl","range":"(0,5 – 8) ppm"},{"name":"Te","range":"(0,5 – 10) ppm"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)"],"technique_en":"Electrothermal atomization atomic absorption spectrometry (ETAAS)","computed":[],"computed_en":[],"activity":"Zawartość Pb, Bi, Sn, Se, Ag, Tl, Te\nZakres:\nPb (0,5 – 10) ppm\nBi (0,3 –10) ppm\nSn (1,0 – 6) ppm\nSe (0,5 – 10) ppm\nAg (0,5 – 4) ppm\nTl (0,5 – 8) ppm\nTe (0,5 – 10) ppm\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","reference":"Procedura nr 24/CHEM, wyd. 8: 10.2025","norm_bases":["Procedura nr 24/CHEM, wyd. 8: 10.2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stopy niklu Zawartość Pb, Bi, Sn, Se, Ag, Tl, Te\nZakres:\nPb (0,5 – 10) ppm\nBi (0,3 –10) ppm\nSn (1,0 – 6) ppm\nSe (0,5 – 10) ppm\nAg (0,5 – 4) ppm\nTl (0,5 – 8) ppm\nTe (0,5 – 10) ppm\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS) Procedura nr 24/CHEM, wyd. 8: 10.2025 Stopy niklu Zawartosc Pb, Bi, Sn, Se, Ag, Tl, Te\nZakres:\nPb (0,5 – 10) ppm\nBi (0,3 –10) ppm\nSn (1,0 – 6) ppm\nSe (0,5 – 10) ppm\nAg (0,5 – 4) ppm\nTl (0,5 – 8) ppm\nTe (0,5 – 10) ppm\nMetoda absorpcyjnej spektrometrii atomowej z atomizacja elektrotermiczna (ETAAS) Procedura nr 24/CHEM, wyd. 8: 10.2025","categories":["other"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Nickel alloys Content of Pb, Bi, Sn, Se, Ag, Tl, Te Electrothermal atomization atomic absorption spectrometry (ETAAS) Pb Bi Sn Se Ag Tl Te Procedura nr 24/CHEM, wyd. 8: 10.2025","parameters_zh":[{"name":"Pb","range":"(0,5 – 10) ppm"},{"name":"Bi","range":"(0,3 –10) ppm"},{"name":"Sn","range":"(1,0 – 6) ppm"},{"name":"Se","range":"(0,5 – 10) ppm"},{"name":"Ag","range":"(0,5 – 4) ppm"},{"name":"Tl","range":"(0,5 – 8) ppm"},{"name":"Te","range":"(0,5 – 10) ppm"}],"search_zh":"电热原子化原子吸收光谱法（ETAAS） Pb Sn Se Ag Tl Procedura nr 24/CHEM, wyd. 8: 10.2025","technique_zh":"电热原子化原子吸收光谱法（ETAAS）"},{"_id":"6a5dc9b6f1c10c8ce825cf31","lab_id":"69ad52a3de79e566650fb2d2","country":"PL","accr_number":"AB 554","accr_body":"PCA","test_object":"Stopy tytanu","test_object_en":"Titanium alloys","methodology":"Zawartość V, Fe, Al, Si","methodology_en":"Content of V, Fe, Al, Si","parameters":[{"name":"V","range":"(2,6 – 14,5) %"},{"name":"Fe","range":"(0,07 – 0,5) %"},{"name":"Al","range":"(2,1 – 6,1) %"},{"name":"Si","range":"(0,01 – 0,075) %"}],"parameters_en":[{"name":"V","range":"(2,6 – 14,5) %"},{"name":"Fe","range":"(0,07 – 0,5) %"},{"name":"Al","range":"(2,1 – 6,1) %"},{"name":"Si","range":"(0,01 – 0,075) %"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","computed":[],"computed_en":[],"activity":"Zawartość V, Fe, Al, Si\nZakres:\nV (2,6 – 14,5) %\nFe (0,07 – 0,5) %\nAl (2,1 – 6,1) %\nSi (0,01 – 0,075) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"Procedura nr 10/CHEM, wyd. 1: 10.2025","norm_bases":["Procedura nr 10/CHEM, wyd. 1: 10.2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stopy tytanu Zawartość V, Fe, Al, Si\nZakres:\nV (2,6 – 14,5) %\nFe (0,07 – 0,5) %\nAl (2,1 – 6,1) %\nSi (0,01 – 0,075) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) Procedura nr 10/CHEM, wyd. 1: 10.2025 Stopy tytanu Zawartosc V, Fe, Al, Si\nZakres:\nV (2,6 – 14,5) %\nFe (0,07 – 0,5) %\nAl (2,1 – 6,1) %\nSi (0,01 – 0,075) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) Procedura nr 10/CHEM, wyd. 1: 10.2025","categories":["other"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Titanium alloys Content of V, Fe, Al, Si Inductively coupled plasma optical emission spectrometry (ICP-OES) V Fe Al Si Procedura nr 10/CHEM, wyd. 1: 10.2025","search_zh":"电感耦合等离子体原子发射光谱法（ICP-OES） V Fe Al Si Procedura nr 10/CHEM, wyd. 1: 10.2025","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","parameters_zh":[{"name":"V","range":"(2,6 – 14,5) %"},{"name":"Fe","range":"(0,07 – 0,5) %"},{"name":"Al","range":"(2,1 – 6,1) %"},{"name":"Si","range":"(0,01 – 0,075) %"}]}],"has_pdf":true}