{"lab":{"_id":"69ad52a3de79e566650fb2c4","accr_number":"AB 543","country":"PL","accr_body":"PCA","address":"ul. Przybyszewskiego 10, 93-189 Łódź","categories":["water","microbiology"],"city":"Łódź","imported_at":"2026-03-08T10:42:43.265Z","methods_count":32,"name":"POWIATOWA STACJA SANITARNO-EPIDEMIOLOGICZNA W ŁODZI","parse_status":"parsed","parse_version":3,"pdf_files":["AB_543.pdf"],"scope_summary":"","search_text":"powiatowa stacja sanitarno-epidemiologiczna w łodzi ul. przybyszewskiego 10, 93-189 łódź other water automotive microbiology pharma electronics petro","status":"active","updated_at":"2026-03-08T14:51:25.382Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:25.382Z","location":{"type":"Point","coordinates":[19.456,51.7592]},"email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20543,podmiot.html","fields_of_testing":[{"codes":"C/28; C/29","pl":"Badania chemiczne wody, wody do spożycia przez ludzi","en":"Chemical tests of air, water, drinking water"},{"codes":"N/28; N/29","pl":"Badania właściwości fizycznych wody, wody do spożycia przez ludzi","en":"Tests of physical properties of water, drinking water"},{"codes":"K/3; K/28; K/29","pl":"Badania mikrobiologiczne obiektów i materiałów biologicznych przeznaczonych do badań, wody i wody do spożycia przez ludzi","en":"Microbiological tests of biological items and materials for testing, water, drinking water"}],"issue":{"no":"26","date":"20.02.2026"},"parse_date":"2026-07-20T07:09:42.473Z","parse_source":"script-pdfplumber","map_coord":[51.743822,19.46563],"map_geo":"nominatim-street","has_en":true,"category_counts":{"water":26,"microbiology":12},"category_scores":{"water":17.79,"microbiology":3.79},"has_zh":true},"methods":[{"_id":"6a5dc9b6f1c10c8ce825cd90","lab_id":"69ad52a3de79e566650fb2c4","country":"PL","accr_number":"AB 543","accr_body":"PCA","test_object":"Woda, Woda do spożycia","test_object_en":"Water, Drinking water","methodology":"Ogólna liczba mikroorganizmów w 36 °C","methodology_en":"Total viable count at 36 °C","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"technique_en":"Plate method (pour plate)","computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w 36 °C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia Ogólna liczba mikroorganizmów w 36 °C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda, Woda do spozycia Ogolna liczba mikroorganizmow w 36 °C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Drinking water Total viable count at 36 °C Plate method (pour plate) PN-EN ISO 6222:2004","methodology_zh":"36 °C 微生物总数","search_zh":"水、饮用水 36 °C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水、饮用水"},{"_id":"6a5dc9b6f1c10c8ce825cd91","lab_id":"69ad52a3de79e566650fb2c4","country":"PL","accr_number":"AB 543","accr_body":"PCA","test_object":"Woda, Woda do spożycia","test_object_en":"Water, Drinking water","methodology":"Ogólna liczba mikroorganizmów w 22 °C","methodology_en":"Total viable count at 22 °C","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"technique_en":"Plate method (pour plate)","computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w 22 °C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia Ogólna liczba mikroorganizmów w 22 °C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda, Woda do spozycia Ogolna liczba mikroorganizmow w 22 °C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Drinking water Total viable count at 22 °C Plate method (pour plate) PN-EN ISO 6222:2004","methodology_zh":"22 °C 微生物总数","search_zh":"水、饮用水 22 °C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水、饮用水"},{"_id":"6a5dc9b6f1c10c8ce825cd92","lab_id":"69ad52a3de79e566650fb2c4","country":"PL","accr_number":"AB 543","accr_body":"PCA","test_object":"Woda, Woda do spożycia","test_object_en":"Water, Drinking water","methodology":"Lliczba enterokoków kałowych","methodology_en":"Count of intestinal enterococci","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Lliczba enterokoków kałowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia Lliczba enterokoków kałowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda, Woda do spozycia Lliczba enterokokow kalowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Drinking water Count of intestinal enterococci Membrane filtration method PN-EN ISO 7899-2:2004","search_zh":"水、饮用水 膜过滤法 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"水、饮用水"},{"_id":"6a5dc9b6f1c10c8ce825cd93","lab_id":"69ad52a3de79e566650fb2c4","country":"PL","accr_number":"AB 543","accr_body":"PCA","test_object":"Woda, Woda do spożycia","test_object_en":"Water, Drinking water","methodology":"Liczba Escherichia coli","methodology_en":"Escherichia coli count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda, Woda do spozycia Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Drinking water Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"水、饮用水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水、饮用水"},{"_id":"6a5dc9b6f1c10c8ce825cd94","lab_id":"69ad52a3de79e566650fb2c4","country":"PL","accr_number":"AB 543","accr_body":"PCA","test_object":"Woda, Woda do spożycia","test_object_en":"Water, Drinking water","methodology":"Liczba bakterii grupy coli","methodology_en":"Coliform bacteria count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda, Woda do spozycia Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Drinking water Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04","methodology_zh":"大肠菌群计数","search_zh":"水、饮用水 大肠菌群计数 膜过滤法 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水、饮用水"},{"_id":"6a5dc9b6f1c10c8ce825cd95","lab_id":"69ad52a3de79e566650fb2c4","country":"PL","accr_number":"AB 543","accr_body":"PCA","test_object":"Woda, Woda do spożycia","test_object_en":"Water, Drinking water","methodology":"Liczba Clostridium perfringens (łącznie z przetrwalnikami)","methodology_en":"Clostridium perfringens count (including spores)","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Clostridium perfringens (łącznie z przetrwalnikami)\nMetoda filtracji membranowej","reference":"PN-EN ISO 14189:2016-10","norm_bases":["PN-EN ISO 14189:2016-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia Liczba Clostridium perfringens (łącznie z przetrwalnikami)\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10 Woda, Woda do spozycia Liczba Clostridium perfringens (lacznie z przetrwalnikami)\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10","categories":["water"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Drinking water Clostridium perfringens count (including spores) Membrane filtration method PN-EN ISO 14189:2016-10","search_zh":"水、饮用水 产气荚膜梭菌数（含芽孢） 膜过滤法 PN-EN ISO 14189:2016-10","technique_zh":"膜过滤法","test_object_zh":"水、饮用水","methodology_zh":"产气荚膜梭菌数（含芽孢）"},{"_id":"6a5dc9b6f1c10c8ce825cd96","lab_id":"69ad52a3de79e566650fb2c4","country":"PL","accr_number":"AB 543","accr_body":"PCA","test_object":"Woda, Woda do spożycia","test_object_en":"Water, Drinking water","methodology":"Liczba Pseudomonas aeruginosa","methodology_en":"Pseudomonas aeruginosa count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009 Woda, Woda do spozycia Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Drinking water Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009","methodology_zh":"铜绿假单胞菌计数","search_zh":"水、饮用水 铜绿假单胞菌计数 膜过滤法 PN-EN ISO 16266:2009","technique_zh":"膜过滤法","test_object_zh":"水、饮用水"},{"_id":"6a5dc9b6f1c10c8ce825cd97","lab_id":"69ad52a3de79e566650fb2c4","country":"PL","accr_number":"AB 543","accr_body":"PCA","test_object":"Woda, Woda do spożycia","test_object_en":"Water, Drinking water","methodology":"Liczba Escherichia coli","methodology_en":"Escherichia coli count","parameters":[],"parameters_en":[],"technique":"Metoda NPL – Colilert-18","techniques":["Metoda NPL – Colilert-18"],"technique_en":"MPN method – Colilert-18","computed":[],"computed_en":[],"activity":"Liczba Escherichia coli\nMetoda NPL – Colilert-18","reference":"PN-EN ISO 9308-2:2014","norm_bases":["PN-EN ISO 9308-2:2014"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia Liczba Escherichia coli\nMetoda NPL – Colilert-18 PN-EN ISO 9308-2:2014 Woda, Woda do spozycia Liczba Escherichia coli\nMetoda NPL – Colilert-18 PN-EN ISO 9308-2:2014","categories":["water","microbiology"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Drinking water Escherichia coli count MPN method – Colilert-18 PN-EN ISO 9308-2:2014","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"水、饮用水 大肠埃希氏菌（Escherichia coli）计数 PN-EN ISO 9308-2:2014","test_object_zh":"水、饮用水"},{"_id":"6a5dc9b6f1c10c8ce825cd98","lab_id":"69ad52a3de79e566650fb2c4","country":"PL","accr_number":"AB 543","accr_body":"PCA","test_object":"Woda, Woda do spożycia","test_object_en":"Water, Drinking water","methodology":"Liczba bakterii grupy coli","methodology_en":"Coliform bacteria count","parameters":[],"parameters_en":[],"technique":"Metoda NPL – Colilert-18","techniques":["Metoda NPL – Colilert-18"],"technique_en":"MPN method – Colilert-18","computed":[],"computed_en":[],"activity":"Liczba bakterii grupy coli\nMetoda NPL – Colilert-18","reference":"PN-EN ISO 9308-2:2014","norm_bases":["PN-EN ISO 9308-2:2014"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia Liczba bakterii grupy coli\nMetoda NPL – Colilert-18 PN-EN ISO 9308-2:2014 Woda, Woda do spozycia Liczba bakterii grupy coli\nMetoda NPL – Colilert-18 PN-EN ISO 9308-2:2014","categories":["water","microbiology"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Drinking water Coliform bacteria count MPN method – Colilert-18 PN-EN ISO 9308-2:2014","methodology_zh":"大肠菌群计数","search_zh":"水、饮用水 大肠菌群计数 PN-EN ISO 9308-2:2014","test_object_zh":"水、饮用水"},{"_id":"6a5dc9b6f1c10c8ce825cd99","lab_id":"69ad52a3de79e566650fb2c4","country":"PL","accr_number":"AB 543","accr_body":"PCA","test_object":"Woda, Woda do spożycia","test_object_en":"Water, Drinking water","methodology":"Liczba gronkowców koagulazododatnich","methodology_en":"Coagulase-positive staphylococci count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba gronkowców koagulazododatnich\nMetoda filtracji membranowej","reference":"PB/L-15 wydanie 4 z dnia 18.02.2016 r. | na podstawie metodyki PZH","norm_bases":["PB/L-15 wydanie 4 z dnia 18.02.2016 r.","na podstawie metodyki PZH"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia Liczba gronkowców koagulazododatnich\nMetoda filtracji membranowej PB/L-15 wydanie 4 z dnia 18.02.2016 r. | na podstawie metodyki PZH Woda, Woda do spozycia Liczba gronkowcow koagulazododatnich\nMetoda filtracji membranowej PB/L-15 wydanie 4 z dnia 18.02.2016 r. | na podstawie metodyki PZH","categories":["water"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Drinking water Coagulase-positive staphylococci count Membrane filtration method PB/L-15 wydanie 4 z dnia 18.02.2016 r. | na podstawie metodyki PZH","search_zh":"水、饮用水 凝固酶阳性葡萄球菌计数 膜过滤法 PB/L-15 wydanie 4 z dnia 18.02.2016 r. | na podstawie metodyki PZH","technique_zh":"膜过滤法","methodology_zh":"凝固酶阳性葡萄球菌计数","test_object_zh":"水、饮用水"},{"_id":"6a5dc9b6f1c10c8ce825cd9a","lab_id":"69ad52a3de79e566650fb2c4","country":"PL","accr_number":"AB 543","accr_body":"PCA","test_object":"Woda do spożycia","test_object_en":"Drinking water","methodology":"Liczba bakterii z rodzaju Legionella zakres od: 1 jtk/100 ml, 1 jtk/1000 ml,","methodology_en":"Count of bacteria of the genus Legionella range from: 1 CFU/100 ml, 1 CFU/1000 ml,","parameters":[{"name":"Matryca A: Procedura 5 (pożywka BCYE) Procedura 7 (pożywka GVPC)"}],"parameters_en":[{"name":"Matrix A: Procedure 5 (medium BCYE) Procedure 7 (medium GVPC)"}],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba bakterii z rodzaju Legionella zakres od: 1 jtk/100 ml, 1 jtk/1000 ml,\nMatryca A: Procedura 5 (pożywka BCYE) Procedura 7 (pożywka GVPC)\nMetoda filtracji membranowej","reference":"PN-EN ISO 11731:2017-08 + Ap1:2019-12","norm_bases":["PN-EN ISO 11731:2017-08 + Ap1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia Liczba bakterii z rodzaju Legionella zakres od: 1 jtk/100 ml, 1 jtk/1000 ml,\nMatryca A: Procedura 5 (pożywka BCYE) Procedura 7 (pożywka GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 + Ap1:2019-12 Woda do spozycia Liczba bakterii z rodzaju Legionella zakres od: 1 jtk/100 ml, 1 jtk/1000 ml,\nMatryca A: Procedura 5 (pozywka BCYE) Procedura 7 (pozywka GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 + Ap1:2019-12","categories":["microbiology","water"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Drinking water Count of bacteria of the genus Legionella range from: 1 CFU/100 ml, 1 CFU/1000 ml, Membrane filtration method Matrix A: Procedure 5 (medium BCYE) Procedure 7 (medium GVPC) PN-EN ISO 11731:2017-08 + Ap1:2019-12","search_zh":"饮用水 膜过滤法 PN-EN ISO 11731:2017-08 + Ap1:2019-12","technique_zh":"膜过滤法","test_object_zh":"饮用水"},{"_id":"6a5dc9b6f1c10c8ce825cd9b","lab_id":"69ad52a3de79e566650fb2c4","country":"PL","accr_number":"AB 543","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Liczba bakterii z rodzaju Legionella zakres od: 1 jtk/100 ml","methodology_en":"Count of bacteria of the genus Legionella range from: 1 CFU/100 ml","parameters":[{"name":"Matryca B: Procedura 7 (pożywka GVPC)"}],"parameters_en":[{"name":"Matrix B: Procedure 7 (medium GVPC)"}],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba bakterii z rodzaju Legionella zakres od: 1 jtk/100 ml\nMatryca B: Procedura 7 (pożywka GVPC)\nMetoda filtracji membranowej","reference":"PN-EN ISO 11731:2017-08 + Ap1:2019-12","norm_bases":["PN-EN ISO 11731:2017-08 + Ap1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Liczba bakterii z rodzaju Legionella zakres od: 1 jtk/100 ml\nMatryca B: Procedura 7 (pożywka GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 + Ap1:2019-12 Woda na plywalniach Liczba bakterii z rodzaju Legionella zakres od: 1 jtk/100 ml\nMatryca B: Procedura 7 (pozywka GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 + Ap1:2019-12","categories":["microbiology","water"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water Count of bacteria of the genus Legionella range from: 1 CFU/100 ml Membrane filtration method Matrix B: Procedure 7 (medium GVPC) PN-EN ISO 11731:2017-08 + Ap1:2019-12","search_zh":"游泳池水 膜过滤法 PN-EN ISO 11731:2017-08 + Ap1:2019-12","technique_zh":"膜过滤法","test_object_zh":"游泳池水"},{"_id":"6a5dc9b6f1c10c8ce825cd9c","lab_id":"69ad52a3de79e566650fb2c4","country":"PL","accr_number":"AB 543","accr_body":"PCA","test_object":"Woda, Woda do spożycia","test_object_en":"Water, Drinking water","methodology":"Stężenie azotynów","methodology_en":"Nitrite concentration","parameters":[{"name":"Zakres","range":"(0,026 – 0,329) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,026 – 0,329) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotynów\nZakres (0,026 – 0,329) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia Stężenie azotynów\nZakres (0,026 – 0,329) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, Woda do spozycia Stezenie azotynow\nZakres (0,026 – 0,329) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Drinking water Nitrite concentration Spectrophotometric method Range PN-EN 26777:1999","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,026 – 0,329) mg/l"}],"search_zh":"水、饮用水 亚硝酸盐浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、饮用水"},{"_id":"6a5dc9b6f1c10c8ce825cd9d","lab_id":"69ad52a3de79e566650fb2c4","country":"PL","accr_number":"AB 543","accr_body":"PCA","test_object":"Woda, Woda do spożycia","test_object_en":"Water, Drinking water","methodology":"Przewodność elektryczna właściwa","methodology_en":"Electrical conductivity","parameters":[{"name":"Zakres","range":"(140 – 1410) μS/cm"}],"parameters_en":[{"name":"Range","range":"(140 – 1410) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"technique_en":"Conductometric method","computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa\nZakres (140 – 1410) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia Przewodność elektryczna właściwa\nZakres (140 – 1410) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, Woda do spozycia Przewodnosc elektryczna wlasciwa\nZakres (140 – 1410) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Drinking water Electrical conductivity Conductometric method Range PN-EN 27888:1999","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(140 – 1410) μS/cm"}],"search_zh":"水、饮用水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、饮用水"},{"_id":"6a5dc9b6f1c10c8ce825cd9e","lab_id":"69ad52a3de79e566650fb2c4","country":"PL","accr_number":"AB 543","accr_body":"PCA","test_object":"Woda, Woda do spożycia","test_object_en":"Water, Drinking water","methodology":"Stężenie żelaza","methodology_en":"Iron concentration","parameters":[{"name":"Zakres","range":"(60 – 2000) μg/l"}],"parameters_en":[{"name":"Range","range":"(60 – 2000) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie żelaza\nZakres (60 – 2000) μg/l\nMetoda spektrofotometryczna","reference":"PN- ISO 6332:2001+ Ap1:2016-06","norm_bases":["PN- ISO 6332:2001+ Ap1:2016-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia Stężenie żelaza\nZakres (60 – 2000) μg/l\nMetoda spektrofotometryczna PN- ISO 6332:2001+ Ap1:2016-06 Woda, Woda do spozycia Stezenie zelaza\nZakres (60 – 2000) μg/l\nMetoda spektrofotometryczna PN- ISO 6332:2001+ Ap1:2016-06","categories":["water"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Drinking water Iron concentration Spectrophotometric method Range PN- ISO 6332:2001+ Ap1:2016-06","methodology_zh":"铁浓度","parameters_zh":[{"name":"范围","range":"(60 – 2000) μg/l"}],"search_zh":"水、饮用水 铁浓度 分光光度法 范围 PN- ISO 6332:2001+ Ap1:2016-06","technique_zh":"分光光度法","test_object_zh":"水、饮用水"},{"_id":"6a5dc9b6f1c10c8ce825cd9f","lab_id":"69ad52a3de79e566650fb2c4","country":"PL","accr_number":"AB 543","accr_body":"PCA","test_object":"Woda, Woda do spożycia","test_object_en":"Water, Drinking water","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"4,0 – 9,2"}],"parameters_en":[{"name":"Range","range":"4,0 – 9,2"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 4,0 – 9,2\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia pH\nZakres 4,0 – 9,2\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, Woda do spozycia pH\nZakres 4,0 – 9,2\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Drinking water pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 9,2"}],"search_zh":"水、饮用水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、饮用水"},{"_id":"6a5dc9b6f1c10c8ce825cda0","lab_id":"69ad52a3de79e566650fb2c4","country":"PL","accr_number":"AB 543","accr_body":"PCA","test_object":"Woda, Woda do spożycia","test_object_en":"Water, Drinking water","methodology":"Stężenie azotanów","methodology_en":"Nitrate concentration","parameters":[{"name":"Zakres","range":"(0,44 – 44) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,44 – 44) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotanów\nZakres (0,44 – 44) mg/l\nMetoda spektrofotometryczna","reference":"PN- 82/C-04576-08","norm_bases":["PN- 82/C-04576-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia Stężenie azotanów\nZakres (0,44 – 44) mg/l\nMetoda spektrofotometryczna PN- 82/C-04576-08 Woda, Woda do spozycia Stezenie azotanow\nZakres (0,44 – 44) mg/l\nMetoda spektrofotometryczna PN- 82/C-04576-08","categories":["water"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Drinking water Nitrate concentration Spectrophotometric method Range PN- 82/C-04576-08","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,44 – 44) mg/l"}],"search_zh":"水、饮用水 硝酸盐浓度 分光光度法 范围 PN- 82/C-04576-08","technique_zh":"分光光度法","test_object_zh":"水、饮用水"},{"_id":"6a5dc9b6f1c10c8ce825cda1","lab_id":"69ad52a3de79e566650fb2c4","country":"PL","accr_number":"AB 543","accr_body":"PCA","test_object":"Woda, Woda do spożycia","test_object_en":"Water, Drinking water","methodology":"Mętność","methodology_en":"Turbidity","parameters":[{"name":"Zakres","range":"(0,10 – 200) NTU"}],"parameters_en":[{"name":"Range","range":"(0,10 – 200) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"technique_en":"Nephelometric method","computed":[],"computed_en":[],"activity":"Mętność\nZakres (0,10 – 200) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016","norm_bases":["PN-EN ISO 7027-1:2016"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia Mętność\nZakres (0,10 – 200) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016 Woda, Woda do spozycia Metnosc\nZakres (0,10 – 200) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016","categories":["water"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Drinking water Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,10 – 200) NTU"}],"search_zh":"水、饮用水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016","technique_zh":"浊度法（散射法）","test_object_zh":"水、饮用水"},{"_id":"6a5dc9b6f1c10c8ce825cda2","lab_id":"69ad52a3de79e566650fb2c4","country":"PL","accr_number":"AB 543","accr_body":"PCA","test_object":"Woda, Woda do spożycia","test_object_en":"Water, Drinking water","methodology":"Stężenie manganu","methodology_en":"Manganese concentration","parameters":[{"name":"Zakres","range":"(20 – 2000) μg/l"}],"parameters_en":[{"name":"Range","range":"(20 – 2000) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie manganu\nZakres (20 – 2000) μg/l\nMetoda spektrofotometryczna","reference":"PB/L-12 wydanie 1 z dnia 8.12.2005 r.","norm_bases":["PB/L-12 wydanie 1 z dnia 8.12.2005 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia Stężenie manganu\nZakres (20 – 2000) μg/l\nMetoda spektrofotometryczna PB/L-12 wydanie 1 z dnia 8.12.2005 r. Woda, Woda do spozycia Stezenie manganu\nZakres (20 – 2000) μg/l\nMetoda spektrofotometryczna PB/L-12 wydanie 1 z dnia 8.12.2005 r.","categories":["water"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Drinking water Manganese concentration Spectrophotometric method Range PB/L-12 wydanie 1 z dnia 8.12.2005 r.","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(20 – 2000) μg/l"}],"search_zh":"水、饮用水 锰浓度 分光光度法 范围 PB/L-12 wydanie 1 z dnia 8.12.2005 r.","technique_zh":"分光光度法","test_object_zh":"水、饮用水"},{"_id":"6a5dc9b6f1c10c8ce825cda3","lab_id":"69ad52a3de79e566650fb2c4","country":"PL","accr_number":"AB 543","accr_body":"PCA","test_object":"Woda, Woda do spożycia","test_object_en":"Water, Drinking water","methodology":"Stężenie fluorków","methodology_en":"Fluoride concentration","parameters":[{"name":"Zakres","range":"(0,10 – 2,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,10 – 2,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie fluorków\nZakres (0,10 – 2,0) mg/l\nMetoda spektrofotometryczna","reference":"PB/L-23 wydanie 1 z dnia 30.03.2007 r.","norm_bases":["PB/L-23 wydanie 1 z dnia 30.03.2007 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia Stężenie fluorków\nZakres (0,10 – 2,0) mg/l\nMetoda spektrofotometryczna PB/L-23 wydanie 1 z dnia 30.03.2007 r. Woda, Woda do spozycia Stezenie fluorkow\nZakres (0,10 – 2,0) mg/l\nMetoda spektrofotometryczna PB/L-23 wydanie 1 z dnia 30.03.2007 r.","categories":["water"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Drinking water Fluoride concentration Spectrophotometric method Range PB/L-23 wydanie 1 z dnia 30.03.2007 r.","parameters_zh":[{"name":"范围","range":"(0,10 – 2,0) mg/l"}],"search_zh":"水、饮用水 氟化物浓度 分光光度法 范围 PB/L-23 wydanie 1 z dnia 30.03.2007 r.","technique_zh":"分光光度法","methodology_zh":"氟化物浓度","test_object_zh":"水、饮用水"},{"_id":"6a5dc9b6f1c10c8ce825cda4","lab_id":"69ad52a3de79e566650fb2c4","country":"PL","accr_number":"AB 543","accr_body":"PCA","test_object":"Woda, Woda do spożycia","test_object_en":"Water, Drinking water","methodology":"Barwa","methodology_en":"Colour","parameters":[{"name":"Zakres","range":"(4 – 30) mg/l Pt"}],"parameters_en":[{"name":"Range","range":"(4 – 30) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Barwa\nZakres (4 – 30) mg/l Pt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012 + Ap1:2015-06 pkt. 6","norm_bases":["PN-EN ISO 7887:2012 + Ap1:2015-06 pkt. 6"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia Barwa\nZakres (4 – 30) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 + Ap1:2015-06 pkt. 6 Woda, Woda do spozycia Barwa\nZakres (4 – 30) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 + Ap1:2015-06 pkt. 6","categories":["water"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Drinking water Colour Spectrophotometric method Range PN-EN ISO 7887:2012 + Ap1:2015-06 pkt. 6","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(4 – 30) mg/l Pt"}],"search_zh":"水、饮用水 色度 分光光度法 范围 PN-EN ISO 7887:2012 + Ap1:2015-06 pkt. 6","technique_zh":"分光光度法","test_object_zh":"水、饮用水"},{"_id":"6a5dc9b6f1c10c8ce825cda5","lab_id":"69ad52a3de79e566650fb2c4","country":"PL","accr_number":"AB 543","accr_body":"PCA","test_object":"Woda, Woda do spożycia","test_object_en":"Water, Drinking water","methodology":"Stężenie glinu","methodology_en":"Aluminium concentration","parameters":[{"name":"Zakres","range":"(60 – 800) μg/l"}],"parameters_en":[{"name":"Range","range":"(60 – 800) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie glinu\nZakres (60 – 800) μg/l\nMetoda spektrofotometryczna","reference":"PB/L-32 wydanie 1 z dnia 10.03.2008 r.","norm_bases":["PB/L-32 wydanie 1 z dnia 10.03.2008 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia Stężenie glinu\nZakres (60 – 800) μg/l\nMetoda spektrofotometryczna PB/L-32 wydanie 1 z dnia 10.03.2008 r. Woda, Woda do spozycia Stezenie glinu\nZakres (60 – 800) μg/l\nMetoda spektrofotometryczna PB/L-32 wydanie 1 z dnia 10.03.2008 r.","categories":["water"],"row_index":21,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Drinking water Aluminium concentration Spectrophotometric method Range PB/L-32 wydanie 1 z dnia 10.03.2008 r.","parameters_zh":[{"name":"范围","range":"(60 – 800) μg/l"}],"search_zh":"水、饮用水 铝浓度 分光光度法 范围 PB/L-32 wydanie 1 z dnia 10.03.2008 r.","technique_zh":"分光光度法","methodology_zh":"铝浓度","test_object_zh":"水、饮用水"},{"_id":"6a5dc9b6f1c10c8ce825cda6","lab_id":"69ad52a3de79e566650fb2c4","country":"PL","accr_number":"AB 543","accr_body":"PCA","test_object":"Woda, Woda do spożycia","test_object_en":"Water, Drinking water","methodology":"Stężenie jonu amonowego","methodology_en":"Ammonium ion concentration","parameters":[{"name":"Zakres","range":"(0,039 – 1,29) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,039 – 1,29) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie jonu amonowego\nZakres (0,039 – 1,29) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia Stężenie jonu amonowego\nZakres (0,039 – 1,29) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, Woda do spozycia Stezenie jonu amonowego\nZakres (0,039 – 1,29) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":22,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Drinking water Ammonium ion concentration Spectrophotometric method Range PN-ISO 7150-1:2002","methodology_zh":"铵离子浓度","parameters_zh":[{"name":"范围","range":"(0,039 – 1,29) mg/l"}],"search_zh":"水、饮用水 铵离子浓度 分光光度法 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水、饮用水"},{"_id":"6a5dc9b6f1c10c8ce825cda7","lab_id":"69ad52a3de79e566650fb2c4","country":"PL","accr_number":"AB 543","accr_body":"PCA","test_object":"Woda, Woda do spożycia","test_object_en":"Water, Drinking water","methodology":"Stężenie chloru wolnego","methodology_en":"Free chlorine concentration","parameters":[{"name":"Zakres","range":"(0,10 – 2,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,10 – 2,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie chloru wolnego\nZakres (0,10 – 2,0) mg/l\nMetoda spektrofotometryczna","reference":"Metoda HACH nr 8021","norm_bases":["Metoda HACH nr 8021"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia Stężenie chloru wolnego\nZakres (0,10 – 2,0) mg/l\nMetoda spektrofotometryczna Metoda HACH nr 8021 Woda, Woda do spozycia Stezenie chloru wolnego\nZakres (0,10 – 2,0) mg/l\nMetoda spektrofotometryczna Metoda HACH nr 8021","categories":["water"],"row_index":23,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Drinking water Free chlorine concentration Spectrophotometric method Range Metoda HACH nr 8021","methodology_zh":"游离氯浓度","parameters_zh":[{"name":"范围","range":"(0,10 – 2,0) mg/l"}],"search_zh":"水、饮用水 游离氯浓度 分光光度法 范围 Metoda HACH nr 8021","technique_zh":"分光光度法","test_object_zh":"水、饮用水"},{"_id":"6a5dc9b6f1c10c8ce825cda8","lab_id":"69ad52a3de79e566650fb2c4","country":"PL","accr_number":"AB 543","accr_body":"PCA","test_object":"Woda, Woda do spożycia","test_object_en":"Water, Drinking water","methodology":"Stężenie chloru całkowitego","methodology_en":"Total chlorine concentration","parameters":[{"name":"Zakres","range":"(0,10 – 2,0) mg/l"},{"name":"Stężenie chloru związanego (z obliczeń)"}],"parameters_en":[{"name":"Range","range":"(0,10 – 2,0) mg/l"},{"name":"Combined chlorine concentration (calculated)"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie chloru całkowitego\nZakres:\nZakres (0,10 – 2,0) mg/l\nStężenie chloru związanego (z obliczeń)\nMetoda spektrofotometryczna","reference":"Metoda HACH nr 8167","norm_bases":["Metoda HACH nr 8167"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia Stężenie chloru całkowitego\nZakres:\nZakres (0,10 – 2,0) mg/l\nStężenie chloru związanego (z obliczeń)\nMetoda spektrofotometryczna Metoda HACH nr 8167 Woda, Woda do spozycia Stezenie chloru calkowitego\nZakres:\nZakres (0,10 – 2,0) mg/l\nStezenie chloru zwiazanego (z obliczen)\nMetoda spektrofotometryczna Metoda HACH nr 8167","categories":["water"],"row_index":24,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Drinking water Total chlorine concentration Spectrophotometric method Range Combined chlorine concentration (calculated) Metoda HACH nr 8167","parameters_zh":[{"name":"范围","range":"(0,10 – 2,0) mg/l"},{"name":"化合氯浓度（计算值）"}],"search_zh":"水、饮用水 总氯浓度 分光光度法 范围 化合氯浓度（计算值） Metoda HACH nr 8167","technique_zh":"分光光度法","methodology_zh":"总氯浓度","test_object_zh":"水、饮用水"},{"_id":"6a5dc9b6f1c10c8ce825cda9","lab_id":"69ad52a3de79e566650fb2c4","country":"PL","accr_number":"AB 543","accr_body":"PCA","test_object":"Woda, Woda do spożycia","test_object_en":"Water, Drinking water","methodology":"Indeks nadmanganianowy","methodology_en":"Permanganate index","parameters":[{"name":"Zakres","range":"(1,0 – 20) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(1,0 – 20) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Indeks nadmanganianowy\nZakres (1,0 – 20) mg/l O2\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia Indeks nadmanganianowy\nZakres (1,0 – 20) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda, Woda do spozycia Indeks nadmanganianowy\nZakres (1,0 – 20) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":25,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Drinking water Permanganate index Titrimetric method Range PN-EN ISO 8467:2001","methodology_zh":"高锰酸盐指数","parameters_zh":[{"name":"范围","range":"(1,0 – 20) mg/l O2"}],"search_zh":"水、饮用水 高锰酸盐指数 滴定法 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"水、饮用水"},{"_id":"6a5dc9b6f1c10c8ce825cdaa","lab_id":"69ad52a3de79e566650fb2c4","country":"PL","accr_number":"AB 543","accr_body":"PCA","test_object":"Biologiczne wskaźniki kontroli skuteczności sterylizacji – sporal „A”","test_object_en":"Biological indicators for sterilization efficacy control – sporal „A”","methodology":"Obecność drobnoustroju wskaźnikowego, Geobacillus stearothermophilus","methodology_en":"Presence of the indicator microorganism, Geobacillus stearothermophilus","parameters":[],"parameters_en":[],"technique":"Metoda hodowlana","techniques":["Metoda hodowlana"],"technique_en":"Culture method","computed":[],"computed_en":[],"activity":"Obecność drobnoustroju wskaźnikowego, Geobacillus stearothermophilus\nMetoda hodowlana","reference":"PB/L-04 wydanie 4 z dnia 15.11.2021 r.","norm_bases":["PB/L-04 wydanie 4 z dnia 15.11.2021 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Biologiczne wskaźniki kontroli skuteczności sterylizacji – sporal „A” Obecność drobnoustroju wskaźnikowego, Geobacillus stearothermophilus\nMetoda hodowlana PB/L-04 wydanie 4 z dnia 15.11.2021 r. Biologiczne wskazniki kontroli skutecznosci sterylizacji – sporal „A” Obecnosc drobnoustroju wskaznikowego, Geobacillus stearothermophilus\nMetoda hodowlana PB/L-04 wydanie 4 z dnia 15.11.2021 r.","categories":["microbiology"],"row_index":26,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Biological indicators for sterilization efficacy control – sporal „A” Presence of the indicator microorganism, Geobacillus stearothermophilus Culture method PB/L-04 wydanie 4 z dnia 15.11.2021 r.","methodology_zh":"指示微生物嗜热脂肪地芽孢杆菌（Geobacillus stearothermophilus）检出","search_zh":"指示微生物嗜热脂肪地芽孢杆菌（Geobacillus stearothermophilus）检出 培养法 PB/L-04 wydanie 4 z dnia 15.11.2021 r.","technique_zh":"培养法"},{"_id":"6a5dc9b6f1c10c8ce825cdab","lab_id":"69ad52a3de79e566650fb2c4","country":"PL","accr_number":"AB 543","accr_body":"PCA","test_object":"Biologiczne wskaźniki kontroli skuteczności sterylizacji – sporal „S”","test_object_en":"Biological indicators for sterilization efficacy control – sporal „S”","methodology":"Obecność drobnoustroju wskaźnikowego Bacillus subtilis","methodology_en":"Presence of the indicator microorganism Bacillus subtilis","parameters":[],"parameters_en":[],"technique":"Metoda hodowlana","techniques":["Metoda hodowlana"],"technique_en":"Culture method","computed":[],"computed_en":[],"activity":"Obecność drobnoustroju wskaźnikowego Bacillus subtilis\nMetoda hodowlana","reference":"PB/L-04 w y d a n i e 4 z d n i a 1 5 . 1 1.2021 r.","norm_bases":["PB/L-04 w y d a n i e 4 z d n i a 1 5 . 1 1.2021 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Biologiczne wskaźniki kontroli skuteczności sterylizacji – sporal „S” Obecność drobnoustroju wskaźnikowego Bacillus subtilis\nMetoda hodowlana PB/L-04 w y d a n i e 4 z d n i a 1 5 . 1 1.2021 r. Biologiczne wskazniki kontroli skutecznosci sterylizacji – sporal „S” Obecnosc drobnoustroju wskaznikowego Bacillus subtilis\nMetoda hodowlana PB/L-04 w y d a n i e 4 z d n i a 1 5 . 1 1.2021 r.","categories":["microbiology"],"row_index":27,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Biological indicators for sterilization efficacy control – sporal „S” Presence of the indicator microorganism Bacillus subtilis Culture method PB/L-04 w y d a n i e 4 z d n i a 1 5 . 1 1.2021 r.","search_zh":"指示微生物枯草芽孢杆菌的检出 培养法 PB/L-04 w y d a n i e 4 z d n i a 1 5 . 1 1.2021 r.","technique_zh":"培养法","methodology_zh":"指示微生物枯草芽孢杆菌的检出"},{"_id":"6a5dc9b6f1c10c8ce825cdac","lab_id":"69ad52a3de79e566650fb2c4","country":"PL","accr_number":"AB 543","accr_body":"PCA","test_object":"Wymazy sanitarne","test_object_en":"Sanitary swabs","methodology":"Obecność drobnoustrojów w warunkach tlenowych – metoda hodowlana","methodology_en":"Presence of microorganisms under aerobic conditions – culture method","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Obecność drobnoustrojów w warunkach tlenowych – metoda hodowlana","reference":"PB/L-05 wydanie 3 z dnia 23.03.2009 r.","norm_bases":["PB/L-05 wydanie 3 z dnia 23.03.2009 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wymazy sanitarne Obecność drobnoustrojów w warunkach tlenowych – metoda hodowlana PB/L-05 wydanie 3 z dnia 23.03.2009 r. Wymazy sanitarne Obecnosc drobnoustrojow w warunkach tlenowych – metoda hodowlana PB/L-05 wydanie 3 z dnia 23.03.2009 r.","categories":["microbiology"],"row_index":28,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sanitary swabs Presence of microorganisms under aerobic conditions – culture method PB/L-05 wydanie 3 z dnia 23.03.2009 r."},{"_id":"6a5dc9b6f1c10c8ce825cdad","lab_id":"69ad52a3de79e566650fb2c4","country":"PL","accr_number":"AB 543","accr_body":"PCA","test_object":"Kał lub wymaz z odbytu","test_object_en":"Faeces or rectal swab","methodology":"Obecność i identyfikacja pałeczek jelitowych z rodzaju Salmonella i Shigella","methodology_en":"Presence and identification of enteric rods of the genus Salmonella and Shigella","parameters":[],"parameters_en":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"technique_en":"Culture method with biochemical and serological confirmation","computed":[],"computed_en":[],"activity":"Obecność i identyfikacja pałeczek jelitowych z rodzaju Salmonella i Shigella\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PB/L-21 w y danie 3 z dnia 14.12.2009 r.","norm_bases":["PB/L-21 w y danie 3 z dnia 14.12.2009 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kał lub wymaz z odbytu Obecność i identyfikacja pałeczek jelitowych z rodzaju Salmonella i Shigella\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB/L-21 w y danie 3 z dnia 14.12.2009 r. Kal lub wymaz z odbytu Obecnosc i identyfikacja paleczek jelitowych z rodzaju Salmonella i Shigella\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB/L-21 w y danie 3 z dnia 14.12.2009 r.","categories":["microbiology"],"row_index":29,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Faeces or rectal swab Presence and identification of enteric rods of the genus Salmonella and Shigella Culture method with biochemical and serological confirmation PB/L-21 w y danie 3 z dnia 14.12.2009 r.","search_zh":"培养法结合生化与血清学确认 PB/L-21 w y danie 3 z dnia 14.12.2009 r.","technique_zh":"培养法结合生化与血清学确认"},{"_id":"6a5dc9b6f1c10c8ce825cdae","lab_id":"69ad52a3de79e566650fb2c4","country":"PL","accr_number":"AB 543","accr_body":"PCA","test_object":"Kał lub wymaz z odbytu","test_object_en":"Faeces or rectal swab","methodology":"Obecność enteropatogennych i enterokrwotocznych Escherichia coli","methodology_en":"Presence of enteropathogenic and enterohaemorrhagic Escherichia coli","parameters":[],"parameters_en":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym"],"technique_en":"Culture method with biochemical confirmation","computed":[],"computed_en":[],"activity":"Obecność enteropatogennych i enterokrwotocznych Escherichia coli\nMetoda hodowlana z potwierdzeniem biochemicznym","reference":"P B / L-08 wydanie 2 z dnia 14.12.2009 r.","norm_bases":["P B / L-08 wydanie 2 z dnia 14.12.2009 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kał lub wymaz z odbytu Obecność enteropatogennych i enterokrwotocznych Escherichia coli\nMetoda hodowlana z potwierdzeniem biochemicznym P B / L-08 wydanie 2 z dnia 14.12.2009 r. Kal lub wymaz z odbytu Obecnosc enteropatogennych i enterokrwotocznych Escherichia coli\nMetoda hodowlana z potwierdzeniem biochemicznym P B / L-08 wydanie 2 z dnia 14.12.2009 r.","categories":["microbiology"],"row_index":30,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Faeces or rectal swab Presence of enteropathogenic and enterohaemorrhagic Escherichia coli Culture method with biochemical confirmation P B / L-08 wydanie 2 z dnia 14.12.2009 r.","search_zh":"培养法结合生化确认 P B / L-08 wydanie 2 z dnia 14.12.2009 r.","technique_zh":"培养法结合生化确认"},{"_id":"6a5dc9b6f1c10c8ce825cdaf","lab_id":"69ad52a3de79e566650fb2c4","country":"PL","accr_number":"AB 543","accr_body":"PCA","test_object":"Kał lub wymaz z odbytu","test_object_en":"Faeces or rectal swab","methodology":"Obecność i identyfikacja bakterii z rodziny Enterobacteriacae","methodology_en":"Presence and identification of bacteria of the family Enterobacteriacae","parameters":[],"parameters_en":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym"],"technique_en":"Culture method with biochemical confirmation","computed":[],"computed_en":[],"activity":"Obecność i identyfikacja bakterii z rodziny Enterobacteriacae\nMetoda hodowlana z potwierdzeniem biochemicznym","reference":"P B/L-07 wydanie 2 z dnia 14.12.2009 r.","norm_bases":["P B/L-07 wydanie 2 z dnia 14.12.2009 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kał lub wymaz z odbytu Obecność i identyfikacja bakterii z rodziny Enterobacteriacae\nMetoda hodowlana z potwierdzeniem biochemicznym P B/L-07 wydanie 2 z dnia 14.12.2009 r. Kal lub wymaz z odbytu Obecnosc i identyfikacja bakterii z rodziny Enterobacteriacae\nMetoda hodowlana z potwierdzeniem biochemicznym P B/L-07 wydanie 2 z dnia 14.12.2009 r.","categories":["microbiology"],"row_index":31,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Faeces or rectal swab Presence and identification of bacteria of the family Enterobacteriacae Culture method with biochemical confirmation P B/L-07 wydanie 2 z dnia 14.12.2009 r.","search_zh":"培养法结合生化确认 P B/L-07 wydanie 2 z dnia 14.12.2009 r.","technique_zh":"培养法结合生化确认"}],"has_pdf":true}