{"lab":{"_id":"69ad52a3de79e566650fb2c2","accr_number":"AB 542","country":"PL","accr_body":"PCA","address":"W WIELUNIU, ul. Polskiej Organizacji Wojskowej 14, 98-300 Wieluń","categories":["water","microbiology"],"city":"Wieluń","imported_at":"2026-03-08T10:42:43.265Z","methods_count":59,"name":"POWIATOWA STACJA SANITARNO-EPIDEMIOLOGICZNA","parse_status":"parsed","parse_version":3,"pdf_files":["AB_542.pdf"],"scope_summary":"","search_text":"powiatowa stacja sanitarno-epidemiologiczna w wieluniu, ul. polskiej organizacji wojskowej 14, 98-300 wieluń water other pharma electronics microbiology automotive petro","status":"active","updated_at":"2026-03-08T14:51:25.307Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-28T00:31:41.755Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20542,podmiot.html","fields_of_testing":[{"codes":"C/28; C/29/P","pl":"Badania chemiczne wody, badania chemiczne i pobieranie próbek wody do spożycia przez ludzi","en":"Chemical tests of water, chemical tests and sampling of drinking water"},{"codes":"D/3","pl":"Badania kliniczne i medyczne obiektów i materiałów biologicznych przeznaczonych do badań","en":"Clinical and medical tests of biological items and materials for testing"},{"codes":"K/3","pl":"Badania mikrobiologiczne obiektów i materiałów biologicznych przeznaczonych do badań","en":"Microbiological tests of biological ithems and materialals for testing"},{"codes":"K/28; K/29/P","pl":"Badania mikrobiologiczne wody, badania mikrobiologiczne i pobieranie próbek wody do spożycia przez ludzi","en":"Microbiological tests of water, microbiological tests and sampling od drinking water"},{"codes":"N/28; N/29/P","pl":"Badania właściwości fizycznych wody, badania właściwości fizycznych i pobieranie próbek wody do spożycia przez ludzi","en":"Phisical tests of water, phisical tests and sampling of drinking water"}],"issue":{"no":"24","date":"26.08.2026"},"parse_date":"2026-08-28T00:31:41.755Z","parse_source":"agent-claude-code","map_coord":[51.218558,18.581463],"map_geo":"nominatim-street","has_en":true,"category_counts":{"water":41,"microbiology":8,"other":1},"category_scores":{"water":33.62,"microbiology":1.28,"other":0.02},"has_zh":true,"lab_locations":[{"name":"ODDZIAŁ LABORATORYJNY","address":"ul. Polskiej Organizacji Wojskowej 14, 98-300 Wieluń","city":"Wieluń","postal":"98-300"},{"name":"Laboratorium Higieny Komunalnej","address":"ul. Polskiej Organizacji Wojskowej 14, 98-300 Wieluń","city":"Wieluń","postal":"98-300"},{"name":"Laboratorium Analiz Instrumentalnych","address":"ul. Polskiej Organizacji Wojskowej 14, 98-300 Wieluń","city":"Wieluń","postal":"98-300"},{"name":"Laboratorium Badań Epidemiologicznych","address":"ul. Polskiej Organizacji Wojskowej 14, 98-300 Wieluń","city":"Wieluń","postal":"98-300"},{"name":"ODDZIAŁ LABORATORYJNY; Laboratorium Analiz Instrumentalnych","address":null,"city":null,"postal":null},{"name":"ODDZIAŁ LABORATORYJNY; Laboratorium Badań Epidemiologicznych","address":null,"city":null,"postal":null},{"name":"ODDZIAŁ LABORATORYJNY; Laboratorium Higieny Komunalnej","address":null,"city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka5","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/27/3b9699f596ae7e0d46213e35a557940d/AB%20542.pdf"},"methods":[{"_id":"6a90d6ed3e9c9f260ef7e66b","lab_id":"69ad52a3de79e566650fb2c2","country":"PL","accr_number":"AB 542","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi","methodology":"pH","parameters":[{"name":"Zakres","range":"(3 – 10)"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres (3 – 10)\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"ODDZIAŁ LABORATORYJNY; Laboratorium Higieny Komunalnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi pH\nZakres (3 – 10)\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda (w tym woda na plywalniach), Woda do spozycia przez ludzi pH\nZakres (3 – 10)\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d6ed3e9c9f260ef7e66c","lab_id":"69ad52a3de79e566650fb2c2","country":"PL","accr_number":"AB 542","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,1 – 1000) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,1 – 1000) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":"ODDZIAŁ LABORATORYJNY; Laboratorium Higieny Komunalnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi Mętność\nZakres (0,1 – 1000) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda (w tym woda na plywalniach), Woda do spozycia przez ludzi Metnosc\nZakres (0,1 – 1000) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d6ed3e9c9f260ef7e66d","lab_id":"69ad52a3de79e566650fb2c2","country":"PL","accr_number":"AB 542","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi","methodology":"Stężenie żelaza ogólnego","parameters":[{"name":"Zakres","range":"(25 – 1000) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza ogólnego\nZakres (25 – 1000) μg/l\nMetoda spektrofotometryczna","reference":"PB/L/LHK-02 wydanie 1 z dnia 07.05.2004 r.","norm_bases":["PB/L/LHK-02 wydanie 1 z dnia 07.05.2004 r."],"lab_section":"ODDZIAŁ LABORATORYJNY; Laboratorium Higieny Komunalnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi Stężenie żelaza ogólnego\nZakres (25 – 1000) μg/l\nMetoda spektrofotometryczna PB/L/LHK-02 wydanie 1 z dnia 07.05.2004 r. Woda (w tym woda na plywalniach), Woda do spozycia przez ludzi Stezenie zelaza ogolnego\nZakres (25 – 1000) μg/l\nMetoda spektrofotometryczna PB/L/LHK-02 wydanie 1 z dnia 07.05.2004 r.","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d6ed3e9c9f260ef7e66e","lab_id":"69ad52a3de79e566650fb2c2","country":"PL","accr_number":"AB 542","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi","methodology":"Stężenie azotanów","parameters":[{"name":"Zakres","range":"(1,0 – 100) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotanów\nZakres (1,0 – 100) mg/l\nMetoda spektrofotometryczna","reference":"PB/L/LHK-07 wydanie 1 z dnia 07.05.2004 r.","norm_bases":["PB/L/LHK-07 wydanie 1 z dnia 07.05.2004 r."],"lab_section":"ODDZIAŁ LABORATORYJNY; Laboratorium Higieny Komunalnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi Stężenie azotanów\nZakres (1,0 – 100) mg/l\nMetoda spektrofotometryczna PB/L/LHK-07 wydanie 1 z dnia 07.05.2004 r. Woda (w tym woda na plywalniach), Woda do spozycia przez ludzi Stezenie azotanow\nZakres (1,0 – 100) mg/l\nMetoda spektrofotometryczna PB/L/LHK-07 wydanie 1 z dnia 07.05.2004 r.","categories":["water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d6ed3e9c9f260ef7e66f","lab_id":"69ad52a3de79e566650fb2c2","country":"PL","accr_number":"AB 542","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi","methodology":"Stężenie chloru wolnego","parameters":[{"name":"Zakres","range":"(0,05 – 2,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chloru wolnego\nZakres (0,05 – 2,00) mg/l\nMetoda spektrofotometryczna","reference":"PB/L/LHK-10 wydanie 1 z dnia 07.05.2004 r.","norm_bases":["PB/L/LHK-10 wydanie 1 z dnia 07.05.2004 r."],"lab_section":"ODDZIAŁ LABORATORYJNY; Laboratorium Higieny Komunalnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi Stężenie chloru wolnego\nZakres (0,05 – 2,00) mg/l\nMetoda spektrofotometryczna PB/L/LHK-10 wydanie 1 z dnia 07.05.2004 r. Woda (w tym woda na plywalniach), Woda do spozycia przez ludzi Stezenie chloru wolnego\nZakres (0,05 – 2,00) mg/l\nMetoda spektrofotometryczna PB/L/LHK-10 wydanie 1 z dnia 07.05.2004 r.","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d6ed3e9c9f260ef7e670","lab_id":"69ad52a3de79e566650fb2c2","country":"PL","accr_number":"AB 542","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi","methodology":"Stężenie glinu","parameters":[{"name":"Zakres","range":"(20 – 250) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie glinu\nZakres (20 – 250) μg/l\nMetoda spektrofotometryczna","reference":"PB/L/LHK-30 wydanie 1 z dnia 05.01.2011 r.","norm_bases":["PB/L/LHK-30 wydanie 1 z dnia 05.01.2011 r."],"lab_section":"ODDZIAŁ LABORATORYJNY; Laboratorium Higieny Komunalnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi Stężenie glinu\nZakres (20 – 250) μg/l\nMetoda spektrofotometryczna PB/L/LHK-30 wydanie 1 z dnia 05.01.2011 r. Woda (w tym woda na plywalniach), Woda do spozycia przez ludzi Stezenie glinu\nZakres (20 – 250) μg/l\nMetoda spektrofotometryczna PB/L/LHK-30 wydanie 1 z dnia 05.01.2011 r.","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d6ed3e9c9f260ef7e671","lab_id":"69ad52a3de79e566650fb2c2","country":"PL","accr_number":"AB 542","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi","methodology":"Indeks nadmanganianowy","parameters":[{"name":"Zakres","range":"(0,5 – 20) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Indeks nadmanganianowy\nZakres (0,5 – 20) mg/l O2\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":"ODDZIAŁ LABORATORYJNY; Laboratorium Higieny Komunalnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi Indeks nadmanganianowy\nZakres (0,5 – 20) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda (w tym woda na plywalniach), Woda do spozycia przez ludzi Indeks nadmanganianowy\nZakres (0,5 – 20) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d6ed3e9c9f260ef7e672","lab_id":"69ad52a3de79e566650fb2c2","country":"PL","accr_number":"AB 542","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(5 – 30) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Barwa\nZakres (5 – 30) mg/l Pt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012 +Ap1:2015-06 pkt 6","norm_bases":["PN-EN ISO 7887:2012 +Ap1:2015-06 pkt 6"],"lab_section":"ODDZIAŁ LABORATORYJNY; Laboratorium Higieny Komunalnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Barwa\nZakres (5 – 30) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 +Ap1:2015-06 pkt 6 Woda, Woda do spozycia przez ludzi Barwa\nZakres (5 – 30) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 +Ap1:2015-06 pkt 6","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d6ed3e9c9f260ef7e673","lab_id":"69ad52a3de79e566650fb2c2","country":"PL","accr_number":"AB 542","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(148 – 1410) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (148 – 1410) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"ODDZIAŁ LABORATORYJNY; Laboratorium Higieny Komunalnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Przewodność elektryczna właściwa\nZakres (148 – 1410) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, Woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa\nZakres (148 – 1410) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d6ed3e9c9f260ef7e674","lab_id":"69ad52a3de79e566650fb2c2","country":"PL","accr_number":"AB 542","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie azotynów","parameters":[{"name":"Zakres","range":"(0,025 – 1,000) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotynów\nZakres (0,025 – 1,000) mg/l\nMetoda spektrofotometryczna","reference":"PB/L/LHK-01 wydanie 1 z dnia 07.05.2004 r.","norm_bases":["PB/L/LHK-01 wydanie 1 z dnia 07.05.2004 r."],"lab_section":"ODDZIAŁ LABORATORYJNY; Laboratorium Higieny Komunalnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie azotynów\nZakres (0,025 – 1,000) mg/l\nMetoda spektrofotometryczna PB/L/LHK-01 wydanie 1 z dnia 07.05.2004 r. Woda, Woda do spozycia przez ludzi Stezenie azotynow\nZakres (0,025 – 1,000) mg/l\nMetoda spektrofotometryczna PB/L/LHK-01 wydanie 1 z dnia 07.05.2004 r.","categories":["water"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d6ed3e9c9f260ef7e675","lab_id":"69ad52a3de79e566650fb2c2","country":"PL","accr_number":"AB 542","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie manganu","parameters":[{"name":"Zakres","range":"(10 – 200) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie manganu\nZakres (10 – 200) μg/l\nMetoda spektrofotometryczna","reference":"PB/L/LHK-05 wydanie 1 z dnia 07.05.2004 r.","norm_bases":["PB/L/LHK-05 wydanie 1 z dnia 07.05.2004 r."],"lab_section":"ODDZIAŁ LABORATORYJNY; Laboratorium Higieny Komunalnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie manganu\nZakres (10 – 200) μg/l\nMetoda spektrofotometryczna PB/L/LHK-05 wydanie 1 z dnia 07.05.2004 r. Woda, Woda do spozycia przez ludzi Stezenie manganu\nZakres (10 – 200) μg/l\nMetoda spektrofotometryczna PB/L/LHK-05 wydanie 1 z dnia 07.05.2004 r.","categories":["water"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d6ed3e9c9f260ef7e676","lab_id":"69ad52a3de79e566650fb2c2","country":"PL","accr_number":"AB 542","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie fluorków","parameters":[{"name":"Zakres","range":"(0,05 – 2,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fluorków\nZakres (0,05 – 2,00) mg/l\nMetoda spektrofotometryczna","reference":"PB/L/LHK-08 wydanie 1 z dnia 07.05.2004 r.","norm_bases":["PB/L/LHK-08 wydanie 1 z dnia 07.05.2004 r."],"lab_section":"ODDZIAŁ LABORATORYJNY; Laboratorium Higieny Komunalnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie fluorków\nZakres (0,05 – 2,00) mg/l\nMetoda spektrofotometryczna PB/L/LHK-08 wydanie 1 z dnia 07.05.2004 r. Woda, Woda do spozycia przez ludzi Stezenie fluorkow\nZakres (0,05 – 2,00) mg/l\nMetoda spektrofotometryczna PB/L/LHK-08 wydanie 1 z dnia 07.05.2004 r.","categories":["water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d6ed3e9c9f260ef7e677","lab_id":"69ad52a3de79e566650fb2c2","country":"PL","accr_number":"AB 542","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie jonu amonowego","parameters":[{"name":"Zakres","range":"(0,05 – 2,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie jonu amonowego\nZakres (0,05 – 2,0) mg/l\nMetoda spektrofotometryczna","reference":"PB/L/LHK-06 wydanie 1 z dnia 07.05.2004 r.","norm_bases":["PB/L/LHK-06 wydanie 1 z dnia 07.05.2004 r."],"lab_section":"ODDZIAŁ LABORATORYJNY; Laboratorium Higieny Komunalnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie jonu amonowego\nZakres (0,05 – 2,0) mg/l\nMetoda spektrofotometryczna PB/L/LHK-06 wydanie 1 z dnia 07.05.2004 r. Woda, Woda do spozycia przez ludzi Stezenie jonu amonowego\nZakres (0,05 – 2,0) mg/l\nMetoda spektrofotometryczna PB/L/LHK-06 wydanie 1 z dnia 07.05.2004 r.","categories":["water"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d6ed3e9c9f260ef7e678","lab_id":"69ad52a3de79e566650fb2c2","country":"PL","accr_number":"AB 542","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(3,0 – 300) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie siarczanów\nZakres (3,0 – 300) mg/l\nMetoda spektrofotometryczna","reference":"PB/L/LHK-09 wydanie 2 z dnia 12.11.2008 r.","norm_bases":["PB/L/LHK-09 wydanie 2 z dnia 12.11.2008 r."],"lab_section":"ODDZIAŁ LABORATORYJNY; Laboratorium Higieny Komunalnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie siarczanów\nZakres (3,0 – 300) mg/l\nMetoda spektrofotometryczna PB/L/LHK-09 wydanie 2 z dnia 12.11.2008 r. Woda, Woda do spozycia przez ludzi Stezenie siarczanow\nZakres (3,0 – 300) mg/l\nMetoda spektrofotometryczna PB/L/LHK-09 wydanie 2 z dnia 12.11.2008 r.","categories":["water"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d6ed3e9c9f260ef7e679","lab_id":"69ad52a3de79e566650fb2c2","country":"PL","accr_number":"AB 542","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5,0 – 300) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5,0 – 300) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"ODDZIAŁ LABORATORYJNY; Laboratorium Higieny Komunalnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie chlorków\nZakres (5,0 – 300) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda, Woda do spozycia przez ludzi Stezenie chlorkow\nZakres (5,0 – 300) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d6ed3e9c9f260ef7e67a","lab_id":"69ad52a3de79e566650fb2c2","country":"PL","accr_number":"AB 542","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Twardość ogólna","parameters":[{"name":"Zakres","range":"(5 – 500) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Twardość ogólna\nZakres (5 – 500) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":"ODDZIAŁ LABORATORYJNY; Laboratorium Higieny Komunalnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Twardość ogólna\nZakres (5 – 500) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999 Woda, Woda do spozycia przez ludzi Twardosc ogolna\nZakres (5 – 500) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d6ed3e9c9f260ef7e67b","lab_id":"69ad52a3de79e566650fb2c2","country":"PL","accr_number":"AB 542","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie wapnia","parameters":[{"name":"Zakres","range":"(2 – 150) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie wapnia\nZakres (2 – 150) mg/l\nMetoda miareczkowa","reference":"PN-ISO 6058:1999","norm_bases":["PN-ISO 6058:1999"],"lab_section":"ODDZIAŁ LABORATORYJNY; Laboratorium Higieny Komunalnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie wapnia\nZakres (2 – 150) mg/l\nMetoda miareczkowa PN-ISO 6058:1999 Woda, Woda do spozycia przez ludzi Stezenie wapnia\nZakres (2 – 150) mg/l\nMetoda miareczkowa PN-ISO 6058:1999","categories":["water"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d6ed3e9c9f260ef7e67c","lab_id":"69ad52a3de79e566650fb2c2","country":"PL","accr_number":"AB 542","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie magnezu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie magnezu (z obliczeń)","reference":"PN-ISO 6058:1999","norm_bases":["PN-ISO 6058:1999"],"lab_section":"ODDZIAŁ LABORATORYJNY; Laboratorium Higieny Komunalnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie magnezu (z obliczeń) PN-ISO 6058:1999 Woda, Woda do spozycia przez ludzi Stezenie magnezu (z obliczen) PN-ISO 6058:1999","categories":["water"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d6ed3e9c9f260ef7e67d","lab_id":"69ad52a3de79e566650fb2c2","country":"PL","accr_number":"AB 542","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Stężenie chloru całkowitego","parameters":[{"name":"Zakres","range":"(0,05 – 2,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chloru całkowitego\nZakres (0,05 – 2,00) mg/l\nMetoda spektrofotometryczna","reference":"PB/L/LHK-32 wydanie 1 z dnia 16.12.2015 r.","norm_bases":["PB/L/LHK-32 wydanie 1 z dnia 16.12.2015 r."],"lab_section":"ODDZIAŁ LABORATORYJNY; Laboratorium Higieny Komunalnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Stężenie chloru całkowitego\nZakres (0,05 – 2,00) mg/l\nMetoda spektrofotometryczna PB/L/LHK-32 wydanie 1 z dnia 16.12.2015 r. Woda na plywalniach Stezenie chloru calkowitego\nZakres (0,05 – 2,00) mg/l\nMetoda spektrofotometryczna PB/L/LHK-32 wydanie 1 z dnia 16.12.2015 r.","categories":["water"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d6ed3e9c9f260ef7e67e","lab_id":"69ad52a3de79e566650fb2c2","country":"PL","accr_number":"AB 542","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Stężenie chloru związanego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie chloru związanego (z obliczeń)","reference":"PB/L/LHK-32 wydanie 1 z dnia 16.12.2015 r.","norm_bases":["PB/L/LHK-32 wydanie 1 z dnia 16.12.2015 r."],"lab_section":"ODDZIAŁ LABORATORYJNY; Laboratorium Higieny Komunalnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Stężenie chloru związanego (z obliczeń) PB/L/LHK-32 wydanie 1 z dnia 16.12.2015 r. Woda na plywalniach Stezenie chloru zwiazanego (z obliczen) PB/L/LHK-32 wydanie 1 z dnia 16.12.2015 r.","categories":["water"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d6ed3e9c9f260ef7e67f","lab_id":"69ad52a3de79e566650fb2c2","country":"PL","accr_number":"AB 542","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Ogólna liczba mikroorganizmów na agarze odżywczym w temperaturze 36oC","parameters":[],"technique":"Metoda płytkowa / posiew wgłębny","techniques":["Metoda płytkowa / posiew wgłębny"],"computed":[],"activity":"Ogólna liczba mikroorganizmów na agarze odżywczym w temperaturze 36oC\nMetoda płytkowa / posiew wgłębny","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"ODDZIAŁ LABORATORYJNY; Laboratorium Higieny Komunalnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Ogólna liczba mikroorganizmów na agarze odżywczym w temperaturze 36oC\nMetoda płytkowa / posiew wgłębny PN-EN ISO 6222:2004 Woda na plywalniach Ogolna liczba mikroorganizmow na agarze odzywczym w temperaturze 36oC\nMetoda plytkowa / posiew wglebny PN-EN ISO 6222:2004","categories":["water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d6ed3e9c9f260ef7e680","lab_id":"69ad52a3de79e566650fb2c2","country":"PL","accr_number":"AB 542","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Liczba bakterii z rodzaju Legionella, Matrix B, procedura 7 (pożywka C – GVPC)","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii z rodzaju Legionella, Matrix B, procedura 7 (pożywka C – GVPC)\nMetoda filtracji membranowej","reference":"PN-EN ISO 11731:2017-08 +Ap1:2019-12","norm_bases":["PN-EN ISO 11731:2017-08 +Ap1:2019-12"],"lab_section":"ODDZIAŁ LABORATORYJNY; Laboratorium Higieny Komunalnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Liczba bakterii z rodzaju Legionella, Matrix B, procedura 7 (pożywka C – GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 +Ap1:2019-12 Woda na plywalniach Liczba bakterii z rodzaju Legionella, Matrix B, procedura 7 (pozywka C – GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 +Ap1:2019-12","categories":["microbiology","water"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d6ed3e9c9f260ef7e681","lab_id":"69ad52a3de79e566650fb2c2","country":"PL","accr_number":"AB 542","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Liczba bakterii Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":"ODDZIAŁ LABORATORYJNY; Laboratorium Higieny Komunalnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Liczba bakterii Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda na plywalniach Liczba bakterii Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["microbiology","water"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d6ed3e9c9f260ef7e682","lab_id":"69ad52a3de79e566650fb2c2","country":"PL","accr_number":"AB 542","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Liczba bakterii Pseudomonas aeruginosa","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":"ODDZIAŁ LABORATORYJNY; Laboratorium Higieny Komunalnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Liczba bakterii Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009 Woda na plywalniach Liczba bakterii Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water","microbiology"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d6ed3e9c9f260ef7e683","lab_id":"69ad52a3de79e566650fb2c2","country":"PL","accr_number":"AB 542","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów na agarze odżywczym w temperaturze 22oC","parameters":[],"technique":"Metoda płytkowa / posiew wgłębny","techniques":["Metoda płytkowa / posiew wgłębny"],"computed":[],"activity":"Ogólna liczba mikroorganizmów na agarze odżywczym w temperaturze 22oC\nMetoda płytkowa / posiew wgłębny","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"ODDZIAŁ LABORATORYJNY; Laboratorium Higieny Komunalnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów na agarze odżywczym w temperaturze 22oC\nMetoda płytkowa / posiew wgłębny PN-EN ISO 6222:2004 Woda, Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow na agarze odzywczym w temperaturze 22oC\nMetoda plytkowa / posiew wglebny PN-EN ISO 6222:2004","categories":["water"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d6ed3e9c9f260ef7e684","lab_id":"69ad52a3de79e566650fb2c2","country":"PL","accr_number":"AB 542","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów na agarze odżywczym w temperaturze 36oC","parameters":[],"technique":"Metoda płytkowa / posiew wgłębny","techniques":["Metoda płytkowa / posiew wgłębny"],"computed":[],"activity":"Ogólna liczba mikroorganizmów na agarze odżywczym w temperaturze 36oC\nMetoda płytkowa / posiew wgłębny","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"ODDZIAŁ LABORATORYJNY; Laboratorium Higieny Komunalnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów na agarze odżywczym w temperaturze 36oC\nMetoda płytkowa / posiew wgłębny PN-EN ISO 6222:2004 Woda, Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow na agarze odzywczym w temperaturze 36oC\nMetoda plytkowa / posiew wglebny PN-EN ISO 6222:2004","categories":["water"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d6ed3e9c9f260ef7e685","lab_id":"69ad52a3de79e566650fb2c2","country":"PL","accr_number":"AB 542","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Liczba enterokoków kałowych","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba enterokoków kałowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":"ODDZIAŁ LABORATORYJNY; Laboratorium Higieny Komunalnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Liczba enterokoków kałowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda, Woda do spozycia przez ludzi Liczba enterokokow kalowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d6ed3e9c9f260ef7e686","lab_id":"69ad52a3de79e566650fb2c2","country":"PL","accr_number":"AB 542","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Liczba bakterii z rodzaju Legionella, Matrix B, procedura 7 (pożywka C – GVPC), Matrix A, procedura 5,7 (pożywka A – BCYE i pożywka C – GVPC)","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii z rodzaju Legionella, Matrix B, procedura 7 (pożywka C – GVPC), Matrix A, procedura 5,7 (pożywka A – BCYE i pożywka C – GVPC)\nMetoda filtracji membranowej","reference":"PN-EN ISO 11731:2017-08 +Ap1:2019-12","norm_bases":["PN-EN ISO 11731:2017-08 +Ap1:2019-12"],"lab_section":"ODDZIAŁ LABORATORYJNY; Laboratorium Higieny Komunalnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Liczba bakterii z rodzaju Legionella, Matrix B, procedura 7 (pożywka C – GVPC), Matrix A, procedura 5,7 (pożywka A – BCYE i pożywka C – GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 +Ap1:2019-12 Woda, Woda do spozycia przez ludzi Liczba bakterii z rodzaju Legionella, Matrix B, procedura 7 (pozywka C – GVPC), Matrix A, procedura 5,7 (pozywka A – BCYE i pozywka C – GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 +Ap1:2019-12","categories":["microbiology","water"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d6ed3e9c9f260ef7e687","lab_id":"69ad52a3de79e566650fb2c2","country":"PL","accr_number":"AB 542","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Liczba bakterii grupy coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":"ODDZIAŁ LABORATORYJNY; Laboratorium Higieny Komunalnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda, Woda do spozycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d6ed3e9c9f260ef7e688","lab_id":"69ad52a3de79e566650fb2c2","country":"PL","accr_number":"AB 542","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Liczba bakterii Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":"ODDZIAŁ LABORATORYJNY; Laboratorium Higieny Komunalnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Liczba bakterii Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda, Woda do spozycia przez ludzi Liczba bakterii Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["microbiology","water"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d6ed3e9c9f260ef7e689","lab_id":"69ad52a3de79e566650fb2c2","country":"PL","accr_number":"AB 542","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Liczba bakterii Pseudomonas aeruginosa","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":"ODDZIAŁ LABORATORYJNY; Laboratorium Higieny Komunalnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Liczba bakterii Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009 Woda, Woda do spozycia przez ludzi Liczba bakterii Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water","microbiology"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d6ed3e9c9f260ef7e68a","lab_id":"69ad52a3de79e566650fb2c2","country":"PL","accr_number":"AB 542","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007","norm_bases":["PN-EN ISO 19458:2007"],"lab_section":"ODDZIAŁ LABORATORYJNY; Laboratorium Higieny Komunalnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 Woda, Woda do spozycia przez ludzi Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007","categories":["water","microbiology"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d6ed3e9c9f260ef7e68b","lab_id":"69ad52a3de79e566650fb2c2","country":"PL","accr_number":"AB 542","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań chemicznych i właściwości fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i właściwości fizycznych","reference":"PN-ISO 5667-5:2017-10","norm_bases":["PN-ISO 5667-5:2017-10"],"lab_section":"ODDZIAŁ LABORATORYJNY; Laboratorium Higieny Komunalnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i właściwości fizycznych PN-ISO 5667-5:2017-10 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i wlasciwosci fizycznych PN-ISO 5667-5:2017-10","categories":["water"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d6ed3e9c9f260ef7e68c","lab_id":"69ad52a3de79e566650fb2c2","country":"PL","accr_number":"AB 542","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi","methodology":"Stężenie łatwolotnych chlorowcowych pochodnych węglowodorów","parameters":[{"name":"Bromoform","range":"(0,6 – 50) μg/l"},{"name":"Chloroform","range":"(0,3 – 95) μg/l"},{"name":"Dibromochlorometan","range":"(0,3 – 50) μg/l"},{"name":"Bromodichlorometan","range":"(0,3 – 50) μg/l"},{"name":"suma THM (z obliczeń)"},{"name":"Zakres","range":"1,2-dichloroetan (0,6 – 10) μg/l"},{"name":"Trichloroeten","range":"(0,3 – 50) μg/l"},{"name":"Tetrachloroeten","range":"(0,3 – 50) μg/l"},{"name":"suma Trichloroetenu i Tetrachloroetenu (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","techniques":["Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)"],"computed":[],"activity":"Stężenie łatwolotnych chlorowcowych pochodnych węglowodorów\nZakres:\nBromoform (0,6 – 50) μg/l\nChloroform (0,3 – 95) μg/l\nDibromochlorometan (0,3 – 50) μg/l\nBromodichlorometan (0,3 – 50) μg/l\nsuma THM (z obliczeń)\nZakres 1,2-dichloroetan (0,6 – 10) μg/l\nTrichloroeten (0,3 – 50) μg/l\nTetrachloroeten (0,3 – 50) μg/l\nsuma Trichloroetenu i Tetrachloroetenu (z obliczeń)\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","reference":"PN-EN ISO 10301:2002 Rozdział 2","norm_bases":["PN-EN ISO 10301:2002 Rozdział 2"],"lab_section":"ODDZIAŁ LABORATORYJNY; Laboratorium Analiz Instrumentalnych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi Stężenie łatwolotnych chlorowcowych pochodnych węglowodorów\nZakres:\nBromoform (0,6 – 50) μg/l\nChloroform (0,3 – 95) μg/l\nDibromochlorometan (0,3 – 50) μg/l\nBromodichlorometan (0,3 – 50) μg/l\nsuma THM (z obliczeń)\nZakres 1,2-dichloroetan (0,6 – 10) μg/l\nTrichloroeten (0,3 – 50) μg/l\nTetrachloroeten (0,3 – 50) μg/l\nsuma Trichloroetenu i Tetrachloroetenu (z obliczeń)\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) PN-EN ISO 10301:2002 Rozdział 2 Woda (w tym woda na plywalniach), Woda do spozycia przez ludzi Stezenie latwolotnych chlorowcowych pochodnych weglowodorow\nZakres:\nBromoform (0,6 – 50) μg/l\nChloroform (0,3 – 95) μg/l\nDibromochlorometan (0,3 – 50) μg/l\nBromodichlorometan (0,3 – 50) μg/l\nsuma THM (z obliczen)\nZakres 1,2-dichloroetan (0,6 – 10) μg/l\nTrichloroeten (0,3 – 50) μg/l\nTetrachloroeten (0,3 – 50) μg/l\nsuma Trichloroetenu i Tetrachloroetenu (z obliczen)\nMetoda chromatografii gazowej z detekcja wychwytu elektronow (GC-ECD) PN-EN ISO 10301:2002 Rozdzial 2","categories":["water"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d6ed3e9c9f260ef7e68d","lab_id":"69ad52a3de79e566650fb2c2","country":"PL","accr_number":"AB 542","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie żelaza","parameters":[{"name":"Zakres","range":"(0,500 – 5,00) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie żelaza\nZakres (0,500 – 5,00) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PB/L/LAI-02 Wydanie 1 z dnia 28.02.2024 r.","norm_bases":["PB/L/LAI-02 Wydanie 1 z dnia 28.02.2024 r."],"lab_section":"ODDZIAŁ LABORATORYJNY; Laboratorium Analiz Instrumentalnych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie żelaza\nZakres (0,500 – 5,00) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB/L/LAI-02 Wydanie 1 z dnia 28.02.2024 r. Woda, Woda do spozycia przez ludzi Stezenie zelaza\nZakres (0,500 – 5,00) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB/L/LAI-02 Wydanie 1 z dnia 28.02.2024 r.","categories":["water"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d6ed3e9c9f260ef7e68e","lab_id":"69ad52a3de79e566650fb2c2","country":"PL","accr_number":"AB 542","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie manganu","parameters":[{"name":"Zakres","range":"(0,100 – 10) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie manganu\nZakres (0,100 – 10) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PB/L/LAI-02 Wydanie 1 z dnia 28.02.2024 r.","norm_bases":["PB/L/LAI-02 Wydanie 1 z dnia 28.02.2024 r."],"lab_section":"ODDZIAŁ LABORATORYJNY; Laboratorium Analiz Instrumentalnych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie manganu\nZakres (0,100 – 10) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB/L/LAI-02 Wydanie 1 z dnia 28.02.2024 r. Woda, Woda do spozycia przez ludzi Stezenie manganu\nZakres (0,100 – 10) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB/L/LAI-02 Wydanie 1 z dnia 28.02.2024 r.","categories":["water"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d6ed3e9c9f260ef7e68f","lab_id":"69ad52a3de79e566650fb2c2","country":"PL","accr_number":"AB 542","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie sodu","parameters":[{"name":"Zakres","range":"(1,0 – 200) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie sodu\nZakres (1,0 – 200) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PB/L/LAI-02 Wydanie 1 z dnia 28.02.2024 r.","norm_bases":["PB/L/LAI-02 Wydanie 1 z dnia 28.02.2024 r."],"lab_section":"ODDZIAŁ LABORATORYJNY; Laboratorium Analiz Instrumentalnych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie sodu\nZakres (1,0 – 200) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB/L/LAI-02 Wydanie 1 z dnia 28.02.2024 r. Woda, Woda do spozycia przez ludzi Stezenie sodu\nZakres (1,0 – 200) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB/L/LAI-02 Wydanie 1 z dnia 28.02.2024 r.","categories":["water"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d6ed3e9c9f260ef7e690","lab_id":"69ad52a3de79e566650fb2c2","country":"PL","accr_number":"AB 542","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie miedzi","parameters":[{"name":"Zakres","range":"(0,10 – 5,0) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie miedzi\nZakres (0,10 – 5,0) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PB/L/LAI-02 Wydanie 1 z dnia 28.02.2024 r.","norm_bases":["PB/L/LAI-02 Wydanie 1 z dnia 28.02.2024 r."],"lab_section":"ODDZIAŁ LABORATORYJNY; Laboratorium Analiz Instrumentalnych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie miedzi\nZakres (0,10 – 5,0) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB/L/LAI-02 Wydanie 1 z dnia 28.02.2024 r. Woda, Woda do spozycia przez ludzi Stezenie miedzi\nZakres (0,10 – 5,0) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB/L/LAI-02 Wydanie 1 z dnia 28.02.2024 r.","categories":["water"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d6ed3e9c9f260ef7e691","lab_id":"69ad52a3de79e566650fb2c2","country":"PL","accr_number":"AB 542","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie cynku","parameters":[{"name":"Zakres","range":"(0,20 – 20) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie cynku\nZakres (0,20 – 20) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PB/L/LAI-02 Wydanie 1 z dnia 28.02.2024 r.","norm_bases":["PB/L/LAI-02 Wydanie 1 z dnia 28.02.2024 r."],"lab_section":"ODDZIAŁ LABORATORYJNY; Laboratorium Analiz Instrumentalnych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie cynku\nZakres (0,20 – 20) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB/L/LAI-02 Wydanie 1 z dnia 28.02.2024 r. Woda, Woda do spozycia przez ludzi Stezenie cynku\nZakres (0,20 – 20) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB/L/LAI-02 Wydanie 1 z dnia 28.02.2024 r.","categories":["water"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d6ed3e9c9f260ef7e692","lab_id":"69ad52a3de79e566650fb2c2","country":"PL","accr_number":"AB 542","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie żelaza","parameters":[{"name":"Zakres","range":"(0,500 – 5,00) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie żelaza\nZakres (0,500 – 5,00) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PB/L/LAI-01 Wydanie 3 z dnia 02.12.2020 r.","norm_bases":["PB/L/LAI-01 Wydanie 3 z dnia 02.12.2020 r."],"lab_section":"ODDZIAŁ LABORATORYJNY; Laboratorium Analiz Instrumentalnych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie żelaza\nZakres (0,500 – 5,00) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB/L/LAI-01 Wydanie 3 z dnia 02.12.2020 r. Woda, Woda do spozycia przez ludzi Stezenie zelaza\nZakres (0,500 – 5,00) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB/L/LAI-01 Wydanie 3 z dnia 02.12.2020 r.","categories":["water"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d6ed3e9c9f260ef7e693","lab_id":"69ad52a3de79e566650fb2c2","country":"PL","accr_number":"AB 542","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie manganu","parameters":[{"name":"Zakres","range":"(0,050 – 10) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie manganu\nZakres (0,050 – 10) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PB/L/LAI-01 Wydanie 3 z dnia 02.12.2020 r.","norm_bases":["PB/L/LAI-01 Wydanie 3 z dnia 02.12.2020 r."],"lab_section":"ODDZIAŁ LABORATORYJNY; Laboratorium Analiz Instrumentalnych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie manganu\nZakres (0,050 – 10) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB/L/LAI-01 Wydanie 3 z dnia 02.12.2020 r. Woda, Woda do spozycia przez ludzi Stezenie manganu\nZakres (0,050 – 10) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB/L/LAI-01 Wydanie 3 z dnia 02.12.2020 r.","categories":["water"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d6ed3e9c9f260ef7e694","lab_id":"69ad52a3de79e566650fb2c2","country":"PL","accr_number":"AB 542","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie ołowiu","parameters":[{"name":"Zakres","range":"(3,0 – 60) μg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie ołowiu\nZakres (3,0 – 60) μg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PB/L/LAI-01 Wydanie 3 z dnia 02.12.2020 r.","norm_bases":["PB/L/LAI-01 Wydanie 3 z dnia 02.12.2020 r."],"lab_section":"ODDZIAŁ LABORATORYJNY; Laboratorium Analiz Instrumentalnych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie ołowiu\nZakres (3,0 – 60) μg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB/L/LAI-01 Wydanie 3 z dnia 02.12.2020 r. Woda, Woda do spozycia przez ludzi Stezenie olowiu\nZakres (3,0 – 60) μg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB/L/LAI-01 Wydanie 3 z dnia 02.12.2020 r.","categories":["water"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d6ed3e9c9f260ef7e695","lab_id":"69ad52a3de79e566650fb2c2","country":"PL","accr_number":"AB 542","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie chromu","parameters":[{"name":"Zakres","range":"(5,0 - 600) μg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie chromu\nZakres (5,0 - 600) μg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PB/L/LAI-01 Wydanie 3 z dnia 02.12.2020 r.","norm_bases":["PB/L/LAI-01 Wydanie 3 z dnia 02.12.2020 r."],"lab_section":"ODDZIAŁ LABORATORYJNY; Laboratorium Analiz Instrumentalnych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie chromu\nZakres (5,0 - 600) μg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB/L/LAI-01 Wydanie 3 z dnia 02.12.2020 r. Woda, Woda do spozycia przez ludzi Stezenie chromu\nZakres (5,0 - 600) μg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB/L/LAI-01 Wydanie 3 z dnia 02.12.2020 r.","categories":["water"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d6ed3e9c9f260ef7e696","lab_id":"69ad52a3de79e566650fb2c2","country":"PL","accr_number":"AB 542","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie kadmu","parameters":[{"name":"Zakres","range":"(1,0 - 500) μg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie kadmu\nZakres (1,0 - 500) μg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PB/L/LAI-01 Wydanie 3 z dnia 02.12.2020 r.","norm_bases":["PB/L/LAI-01 Wydanie 3 z dnia 02.12.2020 r."],"lab_section":"ODDZIAŁ LABORATORYJNY; Laboratorium Analiz Instrumentalnych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie kadmu\nZakres (1,0 - 500) μg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB/L/LAI-01 Wydanie 3 z dnia 02.12.2020 r. Woda, Woda do spozycia przez ludzi Stezenie kadmu\nZakres (1,0 - 500) μg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB/L/LAI-01 Wydanie 3 z dnia 02.12.2020 r.","categories":["water"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d6ed3e9c9f260ef7e697","lab_id":"69ad52a3de79e566650fb2c2","country":"PL","accr_number":"AB 542","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie sodu","parameters":[{"name":"Zakres","range":"(0,2 – 100) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie sodu\nZakres (0,2 – 100) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PB/L/LAI-01 Wydanie 3 z dnia 02.12.2020 r.","norm_bases":["PB/L/LAI-01 Wydanie 3 z dnia 02.12.2020 r."],"lab_section":"ODDZIAŁ LABORATORYJNY; Laboratorium Analiz Instrumentalnych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie sodu\nZakres (0,2 – 100) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB/L/LAI-01 Wydanie 3 z dnia 02.12.2020 r. Woda, Woda do spozycia przez ludzi Stezenie sodu\nZakres (0,2 – 100) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB/L/LAI-01 Wydanie 3 z dnia 02.12.2020 r.","categories":["water"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d6ed3e9c9f260ef7e698","lab_id":"69ad52a3de79e566650fb2c2","country":"PL","accr_number":"AB 542","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie miedzi","parameters":[{"name":"Zakres","range":"(0,10 – 5,00) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie miedzi\nZakres (0,10 – 5,00) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PB/L/LAI-01 Wydanie 3 z dnia 02.12.2020 r.","norm_bases":["PB/L/LAI-01 Wydanie 3 z dnia 02.12.2020 r."],"lab_section":"ODDZIAŁ LABORATORYJNY; Laboratorium Analiz Instrumentalnych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie miedzi\nZakres (0,10 – 5,00) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB/L/LAI-01 Wydanie 3 z dnia 02.12.2020 r. Woda, Woda do spozycia przez ludzi Stezenie miedzi\nZakres (0,10 – 5,00) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB/L/LAI-01 Wydanie 3 z dnia 02.12.2020 r.","categories":["water"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d6ed3e9c9f260ef7e699","lab_id":"69ad52a3de79e566650fb2c2","country":"PL","accr_number":"AB 542","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie niklu","parameters":[{"name":"Zakres","range":"(5,0 – 800) μg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie niklu\nZakres (5,0 – 800) μg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PB/L/LAI-01 Wydanie 3 z dnia 02.12.2020 r.","norm_bases":["PB/L/LAI-01 Wydanie 3 z dnia 02.12.2020 r."],"lab_section":"ODDZIAŁ LABORATORYJNY; Laboratorium Analiz Instrumentalnych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie niklu\nZakres (5,0 – 800) μg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB/L/LAI-01 Wydanie 3 z dnia 02.12.2020 r. Woda, Woda do spozycia przez ludzi Stezenie niklu\nZakres (5,0 – 800) μg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB/L/LAI-01 Wydanie 3 z dnia 02.12.2020 r.","categories":["water"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d6ed3e9c9f260ef7e69a","lab_id":"69ad52a3de79e566650fb2c2","country":"PL","accr_number":"AB 542","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie cynku","parameters":[{"name":"Zakres","range":"(0,20 – 20) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie cynku\nZakres (0,20 – 20) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PB/L/LAI-01 Wydanie 3 z dnia 02.12.2020 r.","norm_bases":["PB/L/LAI-01 Wydanie 3 z dnia 02.12.2020 r."],"lab_section":"ODDZIAŁ LABORATORYJNY; Laboratorium Analiz Instrumentalnych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie cynku\nZakres (0,20 – 20) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB/L/LAI-01 Wydanie 3 z dnia 02.12.2020 r. Woda, Woda do spozycia przez ludzi Stezenie cynku\nZakres (0,20 – 20) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB/L/LAI-01 Wydanie 3 z dnia 02.12.2020 r.","categories":["water"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d6ed3e9c9f260ef7e69b","lab_id":"69ad52a3de79e566650fb2c2","country":"PL","accr_number":"AB 542","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie kadmu","parameters":[{"name":"Zakres","range":"(1,0 – 20) μg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)"],"computed":[],"activity":"Stężenie kadmu\nZakres (1,0 – 20) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","reference":"PN-EN ISO 15586:2005","norm_bases":["PN-EN ISO 15586:2005"],"lab_section":"ODDZIAŁ LABORATORYJNY; Laboratorium Analiz Instrumentalnych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie kadmu\nZakres (1,0 – 20) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS) PN-EN ISO 15586:2005 Woda, Woda do spozycia przez ludzi Stezenie kadmu\nZakres (1,0 – 20) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacja elektrotermiczna (ETAAS) PN-EN ISO 15586:2005","categories":["water"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d6ed3e9c9f260ef7e69c","lab_id":"69ad52a3de79e566650fb2c2","country":"PL","accr_number":"AB 542","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie ołowiu","parameters":[{"name":"Zakres","range":"(3,0 – 50) μg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)"],"computed":[],"activity":"Stężenie ołowiu\nZakres (3,0 – 50) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","reference":"PN-EN ISO 15586:2005","norm_bases":["PN-EN ISO 15586:2005"],"lab_section":"ODDZIAŁ LABORATORYJNY; Laboratorium Analiz Instrumentalnych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie ołowiu\nZakres (3,0 – 50) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS) PN-EN ISO 15586:2005 Woda, Woda do spozycia przez ludzi Stezenie olowiu\nZakres (3,0 – 50) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacja elektrotermiczna (ETAAS) PN-EN ISO 15586:2005","categories":["water"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d6ed3e9c9f260ef7e69d","lab_id":"69ad52a3de79e566650fb2c2","country":"PL","accr_number":"AB 542","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie chromu","parameters":[{"name":"Zakres","range":"(5,0 – 100) μg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)"],"computed":[],"activity":"Stężenie chromu\nZakres (5,0 – 100) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","reference":"PN-EN ISO 15586:2005","norm_bases":["PN-EN ISO 15586:2005"],"lab_section":"ODDZIAŁ LABORATORYJNY; Laboratorium Analiz Instrumentalnych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie chromu\nZakres (5,0 – 100) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS) PN-EN ISO 15586:2005 Woda, Woda do spozycia przez ludzi Stezenie chromu\nZakres (5,0 – 100) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacja elektrotermiczna (ETAAS) PN-EN ISO 15586:2005","categories":["water"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d6ed3e9c9f260ef7e69e","lab_id":"69ad52a3de79e566650fb2c2","country":"PL","accr_number":"AB 542","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie niklu","parameters":[{"name":"Zakres","range":"(5,0 – 50) μg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)"],"computed":[],"activity":"Stężenie niklu\nZakres (5,0 – 50) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","reference":"PN-EN ISO 15586:2005","norm_bases":["PN-EN ISO 15586:2005"],"lab_section":"ODDZIAŁ LABORATORYJNY; Laboratorium Analiz Instrumentalnych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie niklu\nZakres (5,0 – 50) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS) PN-EN ISO 15586:2005 Woda, Woda do spozycia przez ludzi Stezenie niklu\nZakres (5,0 – 50) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacja elektrotermiczna (ETAAS) PN-EN ISO 15586:2005","categories":["water"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d6ed3e9c9f260ef7e69f","lab_id":"69ad52a3de79e566650fb2c2","country":"PL","accr_number":"AB 542","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie arsenu","parameters":[{"name":"Zakres","range":"(3,0 – 20) μg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)"],"computed":[],"activity":"Stężenie arsenu\nZakres (3,0 – 20) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","reference":"PN-EN ISO 15586:2005","norm_bases":["PN-EN ISO 15586:2005"],"lab_section":"ODDZIAŁ LABORATORYJNY; Laboratorium Analiz Instrumentalnych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie arsenu\nZakres (3,0 – 20) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS) PN-EN ISO 15586:2005 Woda, Woda do spozycia przez ludzi Stezenie arsenu\nZakres (3,0 – 20) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacja elektrotermiczna (ETAAS) PN-EN ISO 15586:2005","categories":["water"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d6ed3e9c9f260ef7e6a0","lab_id":"69ad52a3de79e566650fb2c2","country":"PL","accr_number":"AB 542","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie selenu","parameters":[{"name":"Zakres","range":"(3,0 – 20) μg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)"],"computed":[],"activity":"Stężenie selenu\nZakres (3,0 – 20) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","reference":"PN-EN ISO 15586:2005","norm_bases":["PN-EN ISO 15586:2005"],"lab_section":"ODDZIAŁ LABORATORYJNY; Laboratorium Analiz Instrumentalnych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie selenu\nZakres (3,0 – 20) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS) PN-EN ISO 15586:2005 Woda, Woda do spozycia przez ludzi Stezenie selenu\nZakres (3,0 – 20) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacja elektrotermiczna (ETAAS) PN-EN ISO 15586:2005","categories":["water"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d6ed3e9c9f260ef7e6a1","lab_id":"69ad52a3de79e566650fb2c2","country":"PL","accr_number":"AB 542","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie antymonu","parameters":[{"name":"Zakres","range":"(1,5 – 10) μg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)"],"computed":[],"activity":"Stężenie antymonu\nZakres (1,5 – 10) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","reference":"PN-EN ISO 15586:2005","norm_bases":["PN-EN ISO 15586:2005"],"lab_section":"ODDZIAŁ LABORATORYJNY; Laboratorium Analiz Instrumentalnych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie antymonu\nZakres (1,5 – 10) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS) PN-EN ISO 15586:2005 Woda, Woda do spozycia przez ludzi Stezenie antymonu\nZakres (1,5 – 10) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacja elektrotermiczna (ETAAS) PN-EN ISO 15586:2005","categories":["water"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d6ed3e9c9f260ef7e6a2","lab_id":"69ad52a3de79e566650fb2c2","country":"PL","accr_number":"AB 542","accr_body":"PCA","test_object":"Kał i wymaz z odbytu","methodology":"Obecność i serotyp pałeczek jelitowych z rodzaju Salmonella, Shigella","parameters":[],"technique":"Metoda hodowlana uzupełniona testami biochemicznymi i serologicznymi","techniques":["Metoda hodowlana uzupełniona testami biochemicznymi i serologicznymi"],"computed":[],"activity":"Obecność i serotyp pałeczek jelitowych z rodzaju Salmonella, Shigella\nMetoda hodowlana uzupełniona testami biochemicznymi i serologicznymi","reference":"PB/L/LEp-01 wydanie 2 z dnia 25.04.2014 r.","norm_bases":["PB/L/LEp-01 wydanie 2 z dnia 25.04.2014 r."],"lab_section":"ODDZIAŁ LABORATORYJNY; Laboratorium Badań Epidemiologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kał i wymaz z odbytu Obecność i serotyp pałeczek jelitowych z rodzaju Salmonella, Shigella\nMetoda hodowlana uzupełniona testami biochemicznymi i serologicznymi PB/L/LEp-01 wydanie 2 z dnia 25.04.2014 r. Kal i wymaz z odbytu Obecnosc i serotyp paleczek jelitowych z rodzaju Salmonella, Shigella\nMetoda hodowlana uzupelniona testami biochemicznymi i serologicznymi PB/L/LEp-01 wydanie 2 z dnia 25.04.2014 r.","categories":["microbiology"],"row_index":55,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d6ed3e9c9f260ef7e6a3","lab_id":"69ad52a3de79e566650fb2c2","country":"PL","accr_number":"AB 542","accr_body":"PCA","test_object":"Kał i wymaz z odbytu od osób chorych","methodology":"Obecność i serotyp pałeczek jelitowych z rodzaju Salmonella, Shigella","parameters":[],"technique":"Metoda hodowlana uzupełniona testami biochemicznymi i serologicznymi","techniques":["Metoda hodowlana uzupełniona testami biochemicznymi i serologicznymi"],"computed":[],"activity":"Obecność i serotyp pałeczek jelitowych z rodzaju Salmonella, Shigella\nMetoda hodowlana uzupełniona testami biochemicznymi i serologicznymi","reference":"PB/L/LEp-07 wydanie 2 z dnia 25.04.2014 r.","norm_bases":["PB/L/LEp-07 wydanie 2 z dnia 25.04.2014 r."],"lab_section":"ODDZIAŁ LABORATORYJNY; Laboratorium Badań Epidemiologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kał i wymaz z odbytu od osób chorych Obecność i serotyp pałeczek jelitowych z rodzaju Salmonella, Shigella\nMetoda hodowlana uzupełniona testami biochemicznymi i serologicznymi PB/L/LEp-07 wydanie 2 z dnia 25.04.2014 r. Kal i wymaz z odbytu od osob chorych Obecnosc i serotyp paleczek jelitowych z rodzaju Salmonella, Shigella\nMetoda hodowlana uzupelniona testami biochemicznymi i serologicznymi PB/L/LEp-07 wydanie 2 z dnia 25.04.2014 r.","categories":["microbiology"],"row_index":56,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d6ed3e9c9f260ef7e6a4","lab_id":"69ad52a3de79e566650fb2c2","country":"PL","accr_number":"AB 542","accr_body":"PCA","test_object":"Kał i wymaz z odbytu od osób chorych","methodology":"Obecność enteropatogennych i enterokrwotocznych Escherichia coli","parameters":[],"technique":"Metoda hodowlana uzupełniona testami biochemicznymi i serologicznymi","techniques":["Metoda hodowlana uzupełniona testami biochemicznymi i serologicznymi"],"computed":[],"activity":"Obecność enteropatogennych i enterokrwotocznych Escherichia coli\nMetoda hodowlana uzupełniona testami biochemicznymi i serologicznymi","reference":"PB/L/LEp-07 wydanie 2 z dnia 25.04.2014 r.","norm_bases":["PB/L/LEp-07 wydanie 2 z dnia 25.04.2014 r."],"lab_section":"ODDZIAŁ LABORATORYJNY; Laboratorium Badań Epidemiologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kał i wymaz z odbytu od osób chorych Obecność enteropatogennych i enterokrwotocznych Escherichia coli\nMetoda hodowlana uzupełniona testami biochemicznymi i serologicznymi PB/L/LEp-07 wydanie 2 z dnia 25.04.2014 r. Kal i wymaz z odbytu od osob chorych Obecnosc enteropatogennych i enterokrwotocznych Escherichia coli\nMetoda hodowlana uzupelniona testami biochemicznymi i serologicznymi PB/L/LEp-07 wydanie 2 z dnia 25.04.2014 r.","categories":["microbiology"],"row_index":57,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d6ed3e9c9f260ef7e6a5","lab_id":"69ad52a3de79e566650fb2c2","country":"PL","accr_number":"AB 542","accr_body":"PCA","test_object":"Biologiczne wskaźniki skuteczności procesu sterylizacji, Sporal A, Sporal S","methodology":"Obecność, Geobacillus stearothermophilus, Bacillus subtilis","parameters":[],"technique":"Metoda hodowlana","techniques":["Metoda hodowlana"],"computed":[],"activity":"Obecność, Geobacillus stearothermophilus, Bacillus subtilis\nMetoda hodowlana","reference":"PB/L/LEp-03 wydanie 3 z dnia 24.06.2021 r.","norm_bases":["PB/L/LEp-03 wydanie 3 z dnia 24.06.2021 r."],"lab_section":"ODDZIAŁ LABORATORYJNY; Laboratorium Badań Epidemiologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Biologiczne wskaźniki skuteczności procesu sterylizacji, Sporal A, Sporal S Obecność, Geobacillus stearothermophilus, Bacillus subtilis\nMetoda hodowlana PB/L/LEp-03 wydanie 3 z dnia 24.06.2021 r. Biologiczne wskazniki skutecznosci procesu sterylizacji, Sporal A, Sporal S Obecnosc, Geobacillus stearothermophilus, Bacillus subtilis\nMetoda hodowlana PB/L/LEp-03 wydanie 3 z dnia 24.06.2021 r.","categories":["other"],"row_index":58,"parse_version":4,"parse_source":"agent-claude-code"}],"has_pdf":true}