{"lab":{"_id":"69ad52a3de79e566650fb2bc","accr_number":"AB 538","country":"PL","accr_body":"PCA","address":"W ŁODZI, ul. Wodna 40, 90-046 Łódź","categories":["water","food","microbiology","environment","materials","pharma"],"city":"Łódź","imported_at":"2026-03-08T10:42:43.265Z","methods_count":153,"name":"WOJEWÓDZKA STACJA SANITARNO-EPIDEMIOLOGICZNA","parse_status":"parsed","parse_version":3,"pdf_files":["AB_538.pdf"],"scope_summary":"","search_text":"wojewódzka stacja sanitarno-epidemiologiczna w łodzi, ul. wodna 40, 90-046 łódź other microbiology food pharma materials environment water automotive electronics petro metrology","status":"active","updated_at":"2026-03-08T14:51:24.991Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-09-02T00:38:42.486Z","location":{"type":"Point","coordinates":[19.456,51.7592]},"email_confidence":"high","email_mx":true,"email_source":"https://www.pca.gov.pl/akredytowane-podmioty/akredytacje-aktywne/laboratoria-badawcze/AB%20538,podmiot.html","fields_of_testing":[{"codes":"C/1; C/18; C/21; C/22; C/28, C/29, C/42, C/49","pl":"Badania chemiczne produktów rolnych, papieru, tektury, wyrobów z tworzyw sztucznych, żywności, wody, wody do spożycia przez ludzi, kosmetyków, materiałów opakowaniowych","en":"Chemical tests of agricultural products, paper, cardboard, plastic products, food, water, drinking water, cosmetics, packaging materials"},{"codes":"C/28/P; C/29/P","pl":"Badania chemiczne i pobieranie próbek wody, wody do spożycia przez ludzi","en":"Chemical tests and sampling of water, drinking water"},{"codes":"D/3","pl":"Badania kliniczne medyczne obiektów i materiałów biologicznych przeznaczonych do badań","en":"Clinical, medical tests of biological items and materials for testing"},{"codes":"G/33","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki szkodliwe i uciążliwe – oświetlenie, hałas, mikroklimat, drgania, pole elekromagnetyczne)","en":"Tests concerning environmental engineering (environmental and climatic) – workplace (harmful and nuisance factors – lighting, noice, microclimate, vibration, electromagnetic field)"}],"issue":{"no":"34","date":"10.06.2026"},"parse_date":"2026-09-02T00:38:42.486Z","parse_source":"agent-claude-code","map_coord":[51.761693,19.476822],"map_geo":"nominatim-street","lab_locations":[{"code":null,"name":"WOJEWÓDZKA STACJA SANITARNO-EPIDEMIOLOGICZNA","street":"ul. Wodna 40","postal_code":"90-046","city":"Łódź","is_hq":true,"address":"ul. Wodna 40, 90-046 Łódź","site":"90-046|wodna40"},{"code":null,"name":"Dział Laboratoryjny","street":"ul. Wodna 40","postal_code":"90-046","city":"Łódź","is_hq":false,"address":"ul. Wodna 40, 90-046 Łódź","site":"90-046|wodna40"},{"code":null,"name":"Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych","street":"ul. Wodna 40","postal_code":"90-046","city":"Łódź","is_hq":false,"address":"ul. Wodna 40, 90-046 Łódź","site":"90-046|wodna40"},{"code":null,"name":"Pracownia Badań Mikrobiologicznych","street":"ul. Wodna 40","postal_code":"90-046","city":"Łódź","is_hq":false,"address":"ul. Wodna 40, 90-046 Łódź","site":"90-046|wodna40"},{"code":null,"name":"Pracownia Badań Chemicznych","street":"ul. Wodna 40","postal_code":"90-046","city":"Łódź","is_hq":false,"address":"ul. Wodna 40, 90-046 Łódź","site":"90-046|wodna40"},{"code":null,"name":"Oddział Laboratoryjny Badań Środowiskowych","street":"ul. Wodna 40","postal_code":"90-046","city":"Łódź","is_hq":false,"address":"ul. Wodna 40, 90-046 Łódź","site":"90-046|wodna40"},{"code":null,"name":"Pracownia Badań Biologicznych","street":"ul. Wodna 40","postal_code":"90-046","city":"Łódź","is_hq":false,"address":"ul. Wodna 40, 90-046 Łódź","site":"90-046|wodna40"},{"code":null,"name":"Pracownia Badań Fizykochemicznych","street":"ul. Wodna 40","postal_code":"90-046","city":"Łódź","is_hq":false,"address":"ul. Wodna 40, 90-046 Łódź","site":"90-046|wodna40"},{"code":null,"name":"Sekcja Badania Wody w Zduńskiej Woli","street":"ul. Łaska 13","postal_code":"98-220","city":"Zduńska Wola","is_hq":false,"address":"ul. Łaska 13, 98-220 Zduńska Wola","site":"98-220|łaska13"},{"code":null,"name":"Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych","street":"ul. Wodna 40","postal_code":"90-046","city":"Łódź","is_hq":false,"address":"ul. Wodna 40, 90-046 Łódź","site":"90-046|wodna40"},{"code":null,"name":"Pracownia Badań i Pomiarów Środowiska Pracy","street":"ul. Wodna 40","postal_code":"90-046","city":"Łódź","is_hq":false,"address":"ul. Wodna 40, 90-046 Łódź","site":"90-046|wodna40"},{"code":null,"name":"Pracownia Badań Radiacyjnych","street":"ul. Wodna 40","postal_code":"90-046","city":"Łódź","is_hq":false,"address":"ul. Wodna 40, 90-046 Łódź","site":"90-046|wodna40"},{"code":null,"name":"Oddział Laboratoryjny Mikrobiologii i Epidemiologii","street":"ul. Wodna 40","postal_code":"90-046","city":"Łódź","is_hq":false,"address":"ul. Wodna 40, 90-046 Łódź","site":"90-046|wodna40"},{"code":null,"name":"Pracownia Bakteriologii","street":"ul. Wodna 40","postal_code":"90-046","city":"Łódź","is_hq":false,"address":"ul. Wodna 40, 90-046 Łódź","site":"90-046|wodna40"},{"code":null,"name":"Pracownia Biologii Molekularnej i Serologii","street":"ul. Wodna 40","postal_code":"90-046","city":"Łódź","is_hq":false,"address":"ul. Wodna 40, 90-046 Łódź","site":"90-046|wodna40"},{"code":null,"name":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","street":"","postal_code":"","city":"","is_hq":false,"address":"","site":"|"},{"code":null,"name":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Mikrobiologicznych","street":"","postal_code":"","city":"","is_hq":false,"address":"","site":"|"},{"code":null,"name":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań Radiacyjnych","street":"","postal_code":"","city":"","is_hq":false,"address":"","site":"|"},{"code":null,"name":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań i Pomiarów Środowiska Pracy","street":"","postal_code":"","city":"","is_hq":false,"address":"","site":"|"},{"code":null,"name":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Biologicznych","street":"","postal_code":"","city":"","is_hq":false,"address":"","site":"|"},{"code":null,"name":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Fizykochemicznych","street":"","postal_code":"","city":"","is_hq":false,"address":"","site":"|"},{"code":null,"name":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Fizykochemicznych; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycz","street":"","postal_code":"","city":"","is_hq":false,"address":"","site":"|"},{"code":null,"name":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","street":"","postal_code":"","city":"","is_hq":false,"address":"","site":"|"},{"code":null,"name":"Dział Laboratoryjny; Oddział Laboratoryjny Mikrobiologii i Epidemiologii; Pracownia Bakteriologii","street":"","postal_code":"","city":"","is_hq":false,"address":"","site":"|"},{"code":null,"name":"Dział Laboratoryjny; Oddział Laboratoryjny Mikrobiologii i Epidemiologii; Pracownia Biologii Molekularnej i Serologii","street":"","postal_code":"","city":"","is_hq":false,"address":"","site":"|"}],"scope_format":"PCA::pracownie+elastyczny+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/9/1/5d7eede987dca3a41510ae6a4852c038/AB%20538.pdf","has_en":true,"category_counts":{"water":78,"food":36,"microbiology":27,"environment":25,"materials":15,"other":10,"pharma":9},"category_scores":{"water":30.42,"food":6.48,"microbiology":3.65,"environment":3.13,"materials":1.13,"other":0.5,"pharma":0.41},"has_zh":true,"lab_locations_zh":[{"code":null,"name":"WOJEWÓDZKA STACJA SANITARNO-EPIDEMIOLOGICZNA","street":"ul. Wodna 40","postal_code":"90-046","city":"Łódź","is_hq":true,"address":"ul. Wodna 40, 90-046 Łódź","site":"90-046|wodna40"},{"code":null,"name":"实验室部","street":"ul. Wodna 40","postal_code":"90-046","city":"Łódź","is_hq":false,"address":"ul. Wodna 40, 90-046 Łódź","site":"90-046|wodna40"},{"code":null,"name":"Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych","street":"ul. Wodna 40","postal_code":"90-046","city":"Łódź","is_hq":false,"address":"ul. Wodna 40, 90-046 Łódź","site":"90-046|wodna40"},{"code":null,"name":"Pracownia Badań Mikrobiologicznych","street":"ul. Wodna 40","postal_code":"90-046","city":"Łódź","is_hq":false,"address":"ul. Wodna 40, 90-046 Łódź","site":"90-046|wodna40"},{"code":null,"name":"Pracownia Badań Chemicznych","street":"ul. Wodna 40","postal_code":"90-046","city":"Łódź","is_hq":false,"address":"ul. Wodna 40, 90-046 Łódź","site":"90-046|wodna40"},{"code":null,"name":"Oddział Laboratoryjny Badań Środowiskowych","street":"ul. Wodna 40","postal_code":"90-046","city":"Łódź","is_hq":false,"address":"ul. Wodna 40, 90-046 Łódź","site":"90-046|wodna40"},{"code":null,"name":"Pracownia Badań Biologicznych","street":"ul. Wodna 40","postal_code":"90-046","city":"Łódź","is_hq":false,"address":"ul. Wodna 40, 90-046 Łódź","site":"90-046|wodna40"},{"code":null,"name":"Pracownia Badań Fizykochemicznych","street":"ul. Wodna 40","postal_code":"90-046","city":"Łódź","is_hq":false,"address":"ul. Wodna 40, 90-046 Łódź","site":"90-046|wodna40"},{"code":null,"name":"Sekcja Badania Wody w Zduńskiej Woli","street":"ul. Łaska 13","postal_code":"98-220","city":"Zduńska Wola","is_hq":false,"address":"ul. Łaska 13, 98-220 Zduńska Wola","site":"98-220|łaska13"},{"code":null,"name":"Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych","street":"ul. Wodna 40","postal_code":"90-046","city":"Łódź","is_hq":false,"address":"ul. Wodna 40, 90-046 Łódź","site":"90-046|wodna40"},{"code":null,"name":"工作环境检验与测量室","street":"ul. Wodna 40","postal_code":"90-046","city":"Łódź","is_hq":false,"address":"ul. Wodna 40, 90-046 Łódź","site":"90-046|wodna40"},{"code":null,"name":"Pracownia Badań Radiacyjnych","street":"ul. Wodna 40","postal_code":"90-046","city":"Łódź","is_hq":false,"address":"ul. Wodna 40, 90-046 Łódź","site":"90-046|wodna40"},{"code":null,"name":"Oddział Laboratoryjny Mikrobiologii i Epidemiologii","street":"ul. Wodna 40","postal_code":"90-046","city":"Łódź","is_hq":false,"address":"ul. Wodna 40, 90-046 Łódź","site":"90-046|wodna40"},{"code":null,"name":"Pracownia Bakteriologii","street":"ul. Wodna 40","postal_code":"90-046","city":"Łódź","is_hq":false,"address":"ul. Wodna 40, 90-046 Łódź","site":"90-046|wodna40"},{"code":null,"name":"Pracownia Biologii Molekularnej i Serologii","street":"ul. Wodna 40","postal_code":"90-046","city":"Łódź","is_hq":false,"address":"ul. Wodna 40, 90-046 Łódź","site":"90-046|wodna40"},{"code":null,"name":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","street":"","postal_code":"","city":"","is_hq":false,"address":"","site":"|"},{"code":null,"name":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Mikrobiologicznych","street":"","postal_code":"","city":"","is_hq":false,"address":"","site":"|"},{"code":null,"name":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań Radiacyjnych","street":"","postal_code":"","city":"","is_hq":false,"address":"","site":"|"},{"code":null,"name":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań i Pomiarów Środowiska Pracy","street":"","postal_code":"","city":"","is_hq":false,"address":"","site":"|"},{"code":null,"name":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Biologicznych","street":"","postal_code":"","city":"","is_hq":false,"address":"","site":"|"},{"code":null,"name":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Fizykochemicznych","street":"","postal_code":"","city":"","is_hq":false,"address":"","site":"|"},{"code":null,"name":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Fizykochemicznych; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycz","street":"","postal_code":"","city":"","is_hq":false,"address":"","site":"|"},{"code":null,"name":"Dział Laboratoryjny; Oddział Laboratoryjny Mikrobiologii i Epidemiologii; Pracownia Bakteriologii","street":"","postal_code":"","city":"","is_hq":false,"address":"","site":"|"},{"code":null,"name":"Dział Laboratoryjny; Oddział Laboratoryjny Mikrobiologii i Epidemiologii; Pracownia Biologii Molekularnej i Serologii","street":"","postal_code":"","city":"","is_hq":false,"address":"","site":"|"}]},"methods":[{"_id":"6a9770136972b3d89ffa00c6","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Żywność E","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i mikroskopowym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i mikroskopowym"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym i mikroskopowym","reference":"Normy","norm_bases":["Normy"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Mikrobiologicznych","lab_address":null,"regulatory_area":"E- Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniona publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym i mikroskopowym Normy Zywnosc E Obecnosc drobnoustrojow\nMetoda hodowlana z potwierdzeniem biochemicznym i mikroskopowym Normy","categories":["food","microbiology"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa00c7","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Żywność E","methodology":"Obecność enterotoksyny gronkowcowej","parameters":[],"technique":"Metoda immunoenzymatyczna (ELFA)","techniques":["Metoda immunoenzymatyczna (ELFA)"],"computed":[],"activity":"Obecność enterotoksyny gronkowcowej\nMetoda immunoenzymatyczna (ELFA)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Mikrobiologicznych","lab_address":null,"regulatory_area":"E- Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniona publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Obecność enterotoksyny gronkowcowej\nMetoda immunoenzymatyczna (ELFA) Normy Zywnosc E Obecnosc enterotoksyny gronkowcowej\nMetoda immunoenzymatyczna (ELFA) Normy","categories":["food"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa00c8","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Żywność E","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda płytkowa (posiew powierzchniowy)"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda płytkowa (posiew powierzchniowy)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Mikrobiologicznych","lab_address":null,"regulatory_area":"E- Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniona publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Liczba drobnoustrojów\nMetoda płytkowa (posiew powierzchniowy) Normy Zywnosc E Liczba drobnoustrojow\nMetoda plytkowa (posiew powierzchniowy) Normy","categories":["food","microbiology"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa00c9","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Żywność E","methodology":"Obecność specyficznego DNA, Escherichia coli oraz Escherichia coli wytwarzających toksynę Shiga (STEC) 0103, 0157, 0111, 026, 0145, 0121, 045, 0104","parameters":[],"technique":"Metoda Real Time PCR","techniques":["Metoda Real Time PCR"],"computed":[],"activity":"Obecność specyficznego DNA, Escherichia coli oraz Escherichia coli wytwarzających toksynę Shiga (STEC) 0103, 0157, 0111, 026, 0145, 0121, 045, 0104\nMetoda Real Time PCR","reference":"Normy","norm_bases":["Normy"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Mikrobiologicznych","lab_address":null,"regulatory_area":"E- Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniona publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Obecność specyficznego DNA, Escherichia coli oraz Escherichia coli wytwarzających toksynę Shiga (STEC) 0103, 0157, 0111, 026, 0145, 0121, 045, 0104\nMetoda Real Time PCR Normy Zywnosc E Obecnosc specyficznego DNA, Escherichia coli oraz Escherichia coli wytwarzajacych toksyne Shiga (STEC) 0103, 0157, 0111, 026, 0145, 0121, 045, 0104\nMetoda Real Time PCR Normy","categories":["food","microbiology"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa00ca","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Żywność E","methodology":"Obecność materiału genetycznego wirusów","parameters":[],"technique":"Metoda Real Time RT-PCR","techniques":["Metoda Real Time RT-PCR"],"computed":[],"activity":"Obecność materiału genetycznego wirusów\nMetoda Real Time RT-PCR","reference":"Normy","norm_bases":["Normy"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Mikrobiologicznych","lab_address":null,"regulatory_area":"E- Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniona publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Obecność materiału genetycznego wirusów\nMetoda Real Time RT-PCR Normy Zywnosc E Obecnosc materialu genetycznego wirusow\nMetoda Real Time RT-PCR Normy","categories":["food","materials"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa00cb","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Żywność E, Obiekty z obszaru produkcji żywności E","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"Normy","norm_bases":["Normy"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Mikrobiologicznych","lab_address":null,"regulatory_area":"E- Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniona publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Obiekty z obszaru produkcji żywności E Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym Normy Zywnosc E, Obiekty z obszaru produkcji zywnosci E Obecnosc drobnoustrojow\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym Normy","categories":["food","microbiology"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa00cc","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Żywność E, Obiekty z obszaru produkcji żywności E","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym","reference":"Normy","norm_bases":["Normy"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Mikrobiologicznych","lab_address":null,"regulatory_area":"E- Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniona publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Obiekty z obszaru produkcji żywności E Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym Normy Zywnosc E, Obiekty z obszaru produkcji zywnosci E Obecnosc drobnoustrojow\nMetoda hodowlana z potwierdzeniem biochemicznym Normy","categories":["food","microbiology"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa00cd","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Żywność E, Obiekty z obszaru produkcji żywności E","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Mikrobiologicznych","lab_address":null,"regulatory_area":"E- Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniona publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Obiekty z obszaru produkcji żywności E Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny) Normy Zywnosc E, Obiekty z obszaru produkcji zywnosci E Liczba drobnoustrojow\nMetoda plytkowa (posiew wglebny) Normy","categories":["food","microbiology"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa00ce","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Żywność pochodzenia roślinnego","methodology":"Pozostałość ditiokarbaminianów","parameters":[{"name":"Zakres","range":"(0,010 – 10,00) mg/kg"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC/MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC/MS)"],"computed":[],"activity":"Pozostałość ditiokarbaminianów\nZakres (0,010 – 10,00) mg/kg\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC/MS)","reference":"PB/ L- 112 wydanie 2 z dnia 10.03.2025r.","norm_bases":["PB/ L- 112 wydanie 2 z dnia 10.03.2025r."],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Żywność pochodzenia roślinnego Pozostałość ditiokarbaminianów\nZakres (0,010 – 10,00) mg/kg\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC/MS) PB/ L- 112 wydanie 2 z dnia 10.03.2025r. Zywnosc pochodzenia roslinnego Pozostalosc ditiokarbaminianow\nZakres (0,010 – 10,00) mg/kg\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC/MS) PB/ L- 112 wydanie 2 z dnia 10.03.2025r.","categories":["food"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa00cf","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Żywność pochodzenia roślinnego","methodology":"Zawartość miedzi","parameters":[{"name":"Zakres","range":"(5,0 - 100,0) mg/kg"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Zawartość miedzi\nZakres (5,0 - 100,0) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-EN 14084:2004","norm_bases":["PN-EN 14084:2004"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Żywność pochodzenia roślinnego Zawartość miedzi\nZakres (5,0 - 100,0) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN 14084:2004 Zywnosc pochodzenia roslinnego Zawartosc miedzi\nZakres (5,0 - 100,0) mg/kg\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN 14084:2004","categories":["food"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa00d0","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Świeże ryby, owoce morza i ich przetwory","methodology":"Zawartość histaminy","parameters":[{"name":"Zakres","range":"(15,0 - 480,0) mg/kg"}],"technique":"Metoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC/MS/MS)","techniques":["Metoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC/MS/MS)"],"computed":[],"activity":"Zawartość histaminy\nZakres (15,0 - 480,0) mg/kg\nMetoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC/MS/MS)","reference":"PB/L-113 wydanie 1 z dnia 02.12.2024 r.","norm_bases":["PB/L-113 wydanie 1 z dnia 02.12.2024 r."],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Świeże ryby, owoce morza i ich przetwory Zawartość histaminy\nZakres (15,0 - 480,0) mg/kg\nMetoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC/MS/MS) PB/L-113 wydanie 1 z dnia 02.12.2024 r. Swieze ryby, owoce morza i ich przetwory Zawartosc histaminy\nZakres (15,0 - 480,0) mg/kg\nMetoda chromatografii cieczowej z detekcja tandemowa spektrometria mas (LC/MS/MS) PB/L-113 wydanie 1 z dnia 02.12.2024 r.","categories":["other"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa00d1","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Kawa herbata, koncentraty spożywcze, mięso i produkty mięsne, drób i produkty drobiowe, mleko i produkty mleczne, napoje bezalkoholowe, napoje alkoholowe, owoce i warzywa, przetwory owocowe, warzywne, warzywno- mięsne, ryby i przetwory rybne, słodycze i wyroby cukiernicze, surowce, przetwory zielarskie, przyprawy, środki specjalnego przeznaczenia żywieniowego, tłuszcze roślinne i zwierzęce, zboża i przetwory zbożowe, żywność mrożona, wyroby garmażeryjne, grzyby, sól, suplementy diety substancje dodatkowe, miód, orzechy i ziarna roślin oleistych, ocet, sosy, cukier, drożdże","methodology":"Zawartość rtęci","parameters":[{"name":"Zakres","range":"(0,0005 – 15) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)"],"computed":[],"activity":"Zawartość rtęci\nZakres (0,0005 – 15) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"PB/L-01 wydanie 5 z dnia 16.07.2021 r.","norm_bases":["PB/L-01 wydanie 5 z dnia 16.07.2021 r."],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kawa herbata, koncentraty spożywcze, mięso i produkty mięsne, drób i produkty drobiowe, mleko i produkty mleczne, napoje bezalkoholowe, napoje alkoholowe, owoce i warzywa, przetwory owocowe, warzywne, warzywno- mięsne, ryby i przetwory rybne, słodycze i wyroby cukiernicze, surowce, przetwory zielarskie, przyprawy, środki specjalnego przeznaczenia żywieniowego, tłuszcze roślinne i zwierzęce, zboża i przetwory zbożowe, żywność mrożona, wyroby garmażeryjne, grzyby, sól, suplementy diety substancje dodatkowe, miód, orzechy i ziarna roślin oleistych, ocet, sosy, cukier, drożdże Zawartość rtęci\nZakres (0,0005 – 15) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PB/L-01 wydanie 5 z dnia 16.07.2021 r. Kawa herbata, koncentraty spozywcze, mieso i produkty miesne, drob i produkty drobiowe, mleko i produkty mleczne, napoje bezalkoholowe, napoje alkoholowe, owoce i warzywa, przetwory owocowe, warzywne, warzywno- miesne, ryby i przetwory rybne, slodycze i wyroby cukiernicze, surowce, przetwory zielarskie, przyprawy, srodki specjalnego przeznaczenia zywieniowego, tluszcze roslinne i zwierzece, zboza i przetwory zbozowe, zywnosc mrozona, wyroby garmazeryjne, grzyby, sol, suplementy diety substancje dodatkowe, miod, orzechy i ziarna roslin oleistych, ocet, sosy, cukier, drozdze Zawartosc rteci\nZakres (0,0005 – 15) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PB/L-01 wydanie 5 z dnia 16.07.2021 r.","categories":["food","microbiology","pharma"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa00d2","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Kawa herbata, koncentraty spożywcze, mięso i produkty mięsne, drób i produkty drobiowe, mleko i produkty mleczne, napoje bezalkoholowe, napoje alkoholowe, owoce i warzywa, przetwory owocowe, warzywne, warzywno- mięsne, ryby i przetwory rybne, słodycze i wyroby cukiernicze, surowce, przetwory zielarskie, przyprawy, środki specjalnego przeznaczenia żywieniowego, tłuszcze roślinne i zwierzęce, zboża i przetwory zbożowe, żywność mrożona, wyroby garmażeryjne, grzyby, sól, suplementy diety substancje dodatkowe, miód, orzechy i ziarna roślin oleistych, ocet, sosy, cukier, drożdże","methodology":"Zawartość arsenu","parameters":[{"name":"Zakres","range":"(0,01 – 25,00) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generacją wodorków (HGAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generacją wodorków (HGAAS)"],"computed":[],"activity":"Zawartość arsenu\nZakres (0,01 – 25,00) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generacją wodorków (HGAAS)","reference":"Wydawnictwo Metodyczne Państwowego Zakładu Higieny Warszawa 2005 r.","norm_bases":["Wydawnictwo Metodyczne Państwowego Zakładu Higieny Warszawa 2005 r."],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kawa herbata, koncentraty spożywcze, mięso i produkty mięsne, drób i produkty drobiowe, mleko i produkty mleczne, napoje bezalkoholowe, napoje alkoholowe, owoce i warzywa, przetwory owocowe, warzywne, warzywno- mięsne, ryby i przetwory rybne, słodycze i wyroby cukiernicze, surowce, przetwory zielarskie, przyprawy, środki specjalnego przeznaczenia żywieniowego, tłuszcze roślinne i zwierzęce, zboża i przetwory zbożowe, żywność mrożona, wyroby garmażeryjne, grzyby, sól, suplementy diety substancje dodatkowe, miód, orzechy i ziarna roślin oleistych, ocet, sosy, cukier, drożdże Zawartość arsenu\nZakres (0,01 – 25,00) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generacją wodorków (HGAAS) Wydawnictwo Metodyczne Państwowego Zakładu Higieny Warszawa 2005 r. Kawa herbata, koncentraty spozywcze, mieso i produkty miesne, drob i produkty drobiowe, mleko i produkty mleczne, napoje bezalkoholowe, napoje alkoholowe, owoce i warzywa, przetwory owocowe, warzywne, warzywno- miesne, ryby i przetwory rybne, slodycze i wyroby cukiernicze, surowce, przetwory zielarskie, przyprawy, srodki specjalnego przeznaczenia zywieniowego, tluszcze roslinne i zwierzece, zboza i przetwory zbozowe, zywnosc mrozona, wyroby garmazeryjne, grzyby, sol, suplementy diety substancje dodatkowe, miod, orzechy i ziarna roslin oleistych, ocet, sosy, cukier, drozdze Zawartosc arsenu\nZakres (0,01 – 25,00) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generacja wodorkow (HGAAS) Wydawnictwo Metodyczne Panstwowego Zakladu Higieny Warszawa 2005 r.","categories":["food","microbiology","pharma"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa00d3","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Substancje dodatkowe, Suplementy diety, Kawa herbata, koncentraty spożywcze, mięso i produkty mięsne, drób i produkty drobiowe, mleko i produkty mleczne, owoce i warzywa, przetwory owocowe, warzywne, warzywno-mięsne, ryby i przetwory rybne, słodycze i wyroby cukiernicze, surowce, przetwory zielarskie, przyprawy, środki specjalnego przeznaczenia żywieniowego, zboża i przetwory zbożowe, żywność mrożona, wyroby garmażeryjne, grzyby, sól, miód, orzechy i ziarna roślin oleistych, ocet, sosy, cukier, drożdże","methodology":"Zawartość ołowiu","parameters":[{"name":"Zakres","range":"(0,01 – 20,0) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)"],"computed":[],"activity":"Zawartość ołowiu\nZakres (0,01 – 20,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","reference":"PN-EN 14083:2004","norm_bases":["PN-EN 14083:2004"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Substancje dodatkowe, Suplementy diety, Kawa herbata, koncentraty spożywcze, mięso i produkty mięsne, drób i produkty drobiowe, mleko i produkty mleczne, owoce i warzywa, przetwory owocowe, warzywne, warzywno-mięsne, ryby i przetwory rybne, słodycze i wyroby cukiernicze, surowce, przetwory zielarskie, przyprawy, środki specjalnego przeznaczenia żywieniowego, zboża i przetwory zbożowe, żywność mrożona, wyroby garmażeryjne, grzyby, sól, miód, orzechy i ziarna roślin oleistych, ocet, sosy, cukier, drożdże Zawartość ołowiu\nZakres (0,01 – 20,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS) PN-EN 14083:2004 Substancje dodatkowe, Suplementy diety, Kawa herbata, koncentraty spozywcze, mieso i produkty miesne, drob i produkty drobiowe, mleko i produkty mleczne, owoce i warzywa, przetwory owocowe, warzywne, warzywno-miesne, ryby i przetwory rybne, slodycze i wyroby cukiernicze, surowce, przetwory zielarskie, przyprawy, srodki specjalnego przeznaczenia zywieniowego, zboza i przetwory zbozowe, zywnosc mrozona, wyroby garmazeryjne, grzyby, sol, miod, orzechy i ziarna roslin oleistych, ocet, sosy, cukier, drozdze Zawartosc olowiu\nZakres (0,01 – 20,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z atomizacja elektrotermiczna (ETAAS) PN-EN 14083:2004","categories":["food","microbiology","pharma"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa00d4","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Substancje dodatkowe, Suplementy diety, Kawa herbata, koncentraty spożywcze, mięso i produkty mięsne, drób i produkty drobiowe, mleko i produkty mleczne, owoce i warzywa, przetwory owocowe, warzywne, warzywno-mięsne, ryby i przetwory rybne, słodycze i wyroby cukiernicze, surowce, przetwory zielarskie, przyprawy, środki specjalnego przeznaczenia żywieniowego, zboża i przetwory zbożowe, żywność mrożona, wyroby garmażeryjne, grzyby, sól, miód, orzechy i ziarna roślin oleistych, ocet, sosy, cukier, drożdże","methodology":"Zawartość kadmu","parameters":[{"name":"Zakres","range":"(0,002 – 20,0) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)"],"computed":[],"activity":"Zawartość kadmu\nZakres (0,002 – 20,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","reference":"PN-EN 14083:2004","norm_bases":["PN-EN 14083:2004"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Substancje dodatkowe, Suplementy diety, Kawa herbata, koncentraty spożywcze, mięso i produkty mięsne, drób i produkty drobiowe, mleko i produkty mleczne, owoce i warzywa, przetwory owocowe, warzywne, warzywno-mięsne, ryby i przetwory rybne, słodycze i wyroby cukiernicze, surowce, przetwory zielarskie, przyprawy, środki specjalnego przeznaczenia żywieniowego, zboża i przetwory zbożowe, żywność mrożona, wyroby garmażeryjne, grzyby, sól, miód, orzechy i ziarna roślin oleistych, ocet, sosy, cukier, drożdże Zawartość kadmu\nZakres (0,002 – 20,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS) PN-EN 14083:2004 Substancje dodatkowe, Suplementy diety, Kawa herbata, koncentraty spozywcze, mieso i produkty miesne, drob i produkty drobiowe, mleko i produkty mleczne, owoce i warzywa, przetwory owocowe, warzywne, warzywno-miesne, ryby i przetwory rybne, slodycze i wyroby cukiernicze, surowce, przetwory zielarskie, przyprawy, srodki specjalnego przeznaczenia zywieniowego, zboza i przetwory zbozowe, zywnosc mrozona, wyroby garmazeryjne, grzyby, sol, miod, orzechy i ziarna roslin oleistych, ocet, sosy, cukier, drozdze Zawartosc kadmu\nZakres (0,002 – 20,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z atomizacja elektrotermiczna (ETAAS) PN-EN 14083:2004","categories":["food","microbiology","pharma"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa00d5","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Konserwy mięsne, drobiowe, mleko i produkty mleczne w puszkach, napoje bezalkoholowe w puszkach, owoce i warzywa, przetwory owocowe, warzywne, warzywno-mięsne w puszkach, konserwy rybne, środki specjalnego przeznaczenia żywieniowego w puszkach, Suplementy diety, Substancje dodatkowe","methodology":"Zawartość cyny","parameters":[{"name":"Zakres","range":"(2 – 500) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)"],"computed":[],"activity":"Zawartość cyny\nZakres (2 – 500) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","reference":"PN-EN 15764:2010","norm_bases":["PN-EN 15764:2010"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Konserwy mięsne, drobiowe, mleko i produkty mleczne w puszkach, napoje bezalkoholowe w puszkach, owoce i warzywa, przetwory owocowe, warzywne, warzywno-mięsne w puszkach, konserwy rybne, środki specjalnego przeznaczenia żywieniowego w puszkach, Suplementy diety, Substancje dodatkowe Zawartość cyny\nZakres (2 – 500) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS) PN-EN 15764:2010 Konserwy miesne, drobiowe, mleko i produkty mleczne w puszkach, napoje bezalkoholowe w puszkach, owoce i warzywa, przetwory owocowe, warzywne, warzywno-miesne w puszkach, konserwy rybne, srodki specjalnego przeznaczenia zywieniowego w puszkach, Suplementy diety, Substancje dodatkowe Zawartosc cyny\nZakres (2 – 500) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z atomizacja elektrotermiczna (ETAAS) PN-EN 15764:2010","categories":["food","pharma"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa00d6","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Mięso, podroby i produkty mięsne, drób, podroby drobiowe, produkty drobiarskie, jaja i produkty jajeczne, ryby i owoce morza oraz ich przetwory, mleko i przetwory mleczne, ziarno zbóż i przetwory zbożowe, wyroby cukiernicze, orzechy i ziarna roślin oleistych, zioła i przyprawy, środki spożywcze specjalnego przeznaczenia, cukier, miód, warzywa i ich przetwory, owoce i ich przetwory, grzyby, drożdże, napoje alkoholowe i bezalkoholowe, tłuszcze roślinne, ocet, herbata, herbata ziołowa i owocowa, kawa, suplementy diety","methodology":"Zawartość niklu","parameters":[{"name":"Zakres","range":"(0,05 – 200,00) mg/kg"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Zawartość niklu\nZakres (0,05 – 200,00) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PB/L- 105 wydanie 3 z dnia 02.02.2022r.","norm_bases":["PB/L- 105 wydanie 3 z dnia 02.02.2022r."],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso, podroby i produkty mięsne, drób, podroby drobiowe, produkty drobiarskie, jaja i produkty jajeczne, ryby i owoce morza oraz ich przetwory, mleko i przetwory mleczne, ziarno zbóż i przetwory zbożowe, wyroby cukiernicze, orzechy i ziarna roślin oleistych, zioła i przyprawy, środki spożywcze specjalnego przeznaczenia, cukier, miód, warzywa i ich przetwory, owoce i ich przetwory, grzyby, drożdże, napoje alkoholowe i bezalkoholowe, tłuszcze roślinne, ocet, herbata, herbata ziołowa i owocowa, kawa, suplementy diety Zawartość niklu\nZakres (0,05 – 200,00) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB/L- 105 wydanie 3 z dnia 02.02.2022r. Mieso, podroby i produkty miesne, drob, podroby drobiowe, produkty drobiarskie, jaja i produkty jajeczne, ryby i owoce morza oraz ich przetwory, mleko i przetwory mleczne, ziarno zboz i przetwory zbozowe, wyroby cukiernicze, orzechy i ziarna roslin oleistych, ziola i przyprawy, srodki spozywcze specjalnego przeznaczenia, cukier, miod, warzywa i ich przetwory, owoce i ich przetwory, grzyby, drozdze, napoje alkoholowe i bezalkoholowe, tluszcze roslinne, ocet, herbata, herbata ziolowa i owocowa, kawa, suplementy diety Zawartosc niklu\nZakres (0,05 – 200,00) mg/kg\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB/L- 105 wydanie 3 z dnia 02.02.2022r.","categories":["food","microbiology","pharma"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa00d7","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Ryby, przetwory rybne i owoce morza, zboża i produkty zbożowe, owoce i warzywa, grzyby, przyprawy i zioła, nasiona roślin oleistych i orzechy","methodology":"Zawartość arsenu nieorganicznego.","parameters":[{"name":"Zakres","range":"(0,025 – 2,5) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generacją wodorków (HGAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generacją wodorków (HGAAS)"],"computed":[],"activity":"Zawartość arsenu nieorganicznego.\nZakres (0,025 – 2,5) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generacją wodorków (HGAAS)","reference":"PB/L-110 wyd. 1 z dnia 10.01.2025r.","norm_bases":["PB/L-110 wyd. 1 z dnia 10.01.2025r."],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ryby, przetwory rybne i owoce morza, zboża i produkty zbożowe, owoce i warzywa, grzyby, przyprawy i zioła, nasiona roślin oleistych i orzechy Zawartość arsenu nieorganicznego.\nZakres (0,025 – 2,5) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generacją wodorków (HGAAS) PB/L-110 wyd. 1 z dnia 10.01.2025r. Ryby, przetwory rybne i owoce morza, zboza i produkty zbozowe, owoce i warzywa, grzyby, przyprawy i ziola, nasiona roslin oleistych i orzechy Zawartosc arsenu nieorganicznego.\nZakres (0,025 – 2,5) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generacja wodorkow (HGAAS) PB/L-110 wyd. 1 z dnia 10.01.2025r.","categories":["microbiology"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa00d8","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Soki i napoje bezalkoholowe. Żywność dla niemowląt i małych dzieci oraz środki spożywcze specjalnego przeznaczenia medycznego.","methodology":"Zawartość arsenu nieorganicznego.","parameters":[{"name":"Zakres","range":"(0,010 – 0,25) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generacją wodorków (HGAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generacją wodorków (HGAAS)"],"computed":[],"activity":"Zawartość arsenu nieorganicznego.\nZakres (0,010 – 0,25) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generacją wodorków (HGAAS)","reference":"PB/L-110 wyd. 1 z dnia 10.01.2025r.","norm_bases":["PB/L-110 wyd. 1 z dnia 10.01.2025r."],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Soki i napoje bezalkoholowe. Żywność dla niemowląt i małych dzieci oraz środki spożywcze specjalnego przeznaczenia medycznego. Zawartość arsenu nieorganicznego.\nZakres (0,010 – 0,25) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generacją wodorków (HGAAS) PB/L-110 wyd. 1 z dnia 10.01.2025r. Soki i napoje bezalkoholowe. Zywnosc dla niemowlat i malych dzieci oraz srodki spozywcze specjalnego przeznaczenia medycznego. Zawartosc arsenu nieorganicznego.\nZakres (0,010 – 0,25) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generacja wodorkow (HGAAS) PB/L-110 wyd. 1 z dnia 10.01.2025r.","categories":["food"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa00d9","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość metali szkodliwych dla zdrowia","parameters":[],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"computed":[],"activity":"Zawartość metali szkodliwych dla zdrowia\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":"E- Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniona publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Zawartość metali szkodliwych dla zdrowia\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) Normy Zywnosc E Zawartosc metali szkodliwych dla zdrowia\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) Normy","categories":["materials","food"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa00da","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Żywność pochodzenia roślinnego, produkty rolne E","methodology":"Pozostałość pestycydów","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC/MS/MS)","techniques":["Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC/MS/MS)"],"computed":[],"activity":"Pozostałość pestycydów\nMetoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC/MS/MS)","reference":"PN-EN 15662","norm_bases":["PN-EN 15662"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":"E- Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniona publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność pochodzenia roślinnego, produkty rolne E Pozostałość pestycydów\nMetoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC/MS/MS) PN-EN 15662 Zywnosc pochodzenia roslinnego, produkty rolne E Pozostalosc pestycydow\nMetoda chromatografii gazowej z detekcja tandemowa spektrometria mas (GC/MS/MS) PN-EN 15662","categories":["food"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa00db","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Żywność pochodzenia roślinnego, produkty rolne E","methodology":"Pozostałość pestycydów","parameters":[],"technique":"Metoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC/MS/MS)","techniques":["Metoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC/MS/MS)"],"computed":[],"activity":"Pozostałość pestycydów\nMetoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC/MS/MS)","reference":"PN-EN 15662","norm_bases":["PN-EN 15662"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":"E- Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniona publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność pochodzenia roślinnego, produkty rolne E Pozostałość pestycydów\nMetoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC/MS/MS) PN-EN 15662 Zywnosc pochodzenia roslinnego, produkty rolne E Pozostalosc pestycydow\nMetoda chromatografii cieczowej z detekcja tandemowa spektrometria mas (LC/MS/MS) PN-EN 15662","categories":["food"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa00dc","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA)","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"PB/L-61","norm_bases":["PB/L-61"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":"E- Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniona publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) PB/L-61 Zywnosc E Zawartosc wielopierscieniowych weglowodorow aromatycznych (WWA)\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) PB/L-61","categories":["food"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa00dd","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Żywność pochodzenia roślinnego E","methodology":"Pozostałość pestycydów","parameters":[],"technique":"Metoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC/MS/MS)","techniques":["Metoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC/MS/MS)"],"computed":[],"activity":"Pozostałość pestycydów\nMetoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC/MS/MS)","reference":"EURL-SRM QuPPe-PO-Method","norm_bases":["EURL-SRM QuPPe-PO-Method"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":"E- Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniona publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność pochodzenia roślinnego E Pozostałość pestycydów\nMetoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC/MS/MS) EURL-SRM QuPPe-PO-Method Zywnosc pochodzenia roslinnego E Pozostalosc pestycydow\nMetoda chromatografii cieczowej z detekcja tandemowa spektrometria mas (LC/MS/MS) EURL-SRM QuPPe-PO-Method","categories":["food"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa00de","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Napoje spirytusowe","methodology":"Zawartość metanolu","parameters":[{"name":"Zakres","range":"(2,0 – 2000) g/hl alkoholu 100%"},{"name":"objętości"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC/FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC/FID)"],"computed":[],"activity":"Zawartość metanolu\nZakres:\nZakres (2,0 – 2000) g/hl alkoholu 100%\nobjętości\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC/FID)","reference":"PN-A 79529-7:2005","norm_bases":["PN-A 79529-7:2005"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Napoje spirytusowe Zawartość metanolu\nZakres:\nZakres (2,0 – 2000) g/hl alkoholu 100%\nobjętości\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC/FID) PN-A 79529-7:2005 Napoje spirytusowe Zawartosc metanolu\nZakres:\nZakres (2,0 – 2000) g/hl alkoholu 100%\nobjetosci\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC/FID) PN-A 79529-7:2005","categories":["food"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa00df","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Napoje spirytusowe","methodology":"Moc objętościowa alkoholu","parameters":[{"name":"Zakres","range":"(5,0 – 96,0)%"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC/FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC/FID)"],"computed":[],"activity":"Moc objętościowa alkoholu\nZakres (5,0 – 96,0)%\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC/FID)","reference":"PB/L-90 wyd. 1 z dnia 03.04.2014r.","norm_bases":["PB/L-90 wyd. 1 z dnia 03.04.2014r."],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Napoje spirytusowe Moc objętościowa alkoholu\nZakres (5,0 – 96,0)%\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC/FID) PB/L-90 wyd. 1 z dnia 03.04.2014r. Napoje spirytusowe Moc objetosciowa alkoholu\nZakres (5,0 – 96,0)%\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC/FID) PB/L-90 wyd. 1 z dnia 03.04.2014r.","categories":["food"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa00e0","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Napoje bezalkoholowe, Suplementy diety","methodology":"Zawartość kofeiny","parameters":[{"name":"Zakres","range":"(10 – 1000) mg/l"},{"name":"Zakres","range":"(1 – 500) mg/porcję"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją UV-Vis (HPLC/PDA)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją UV-Vis (HPLC/PDA)"],"computed":[],"activity":"Zawartość kofeiny\nZakres:\nZakres (10 – 1000) mg/l\nZakres (1 – 500) mg/porcję\nMetoda wysokosprawnej chromatografii cieczowej z detekcją UV-Vis (HPLC/PDA)","reference":"PB/L-92 wyd. 3 z dnia 28.02.2022r.","norm_bases":["PB/L-92 wyd. 3 z dnia 28.02.2022r."],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Napoje bezalkoholowe, Suplementy diety Zawartość kofeiny\nZakres:\nZakres (10 – 1000) mg/l\nZakres (1 – 500) mg/porcję\nMetoda wysokosprawnej chromatografii cieczowej z detekcją UV-Vis (HPLC/PDA) PB/L-92 wyd. 3 z dnia 28.02.2022r. Napoje bezalkoholowe, Suplementy diety Zawartosc kofeiny\nZakres:\nZakres (10 – 1000) mg/l\nZakres (1 – 500) mg/porcje\nMetoda wysokosprawnej chromatografii cieczowej z detekcja UV-Vis (HPLC/PDA) PB/L-92 wyd. 3 z dnia 28.02.2022r.","categories":["food","pharma"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa00e1","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Suplementy diety","methodology":"Zawartość diosminy","parameters":[{"name":"Zakres","range":"(10 – 600) mg/porcję"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją UV-Vis (HPLC/PDA)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją UV-Vis (HPLC/PDA)"],"computed":[],"activity":"Zawartość diosminy\nZakres (10 – 600) mg/porcję\nMetoda wysokosprawnej chromatografii cieczowej z detekcją UV-Vis (HPLC/PDA)","reference":"PB/L-101 wyd. 3 z dnia 28.02.2022r.","norm_bases":["PB/L-101 wyd. 3 z dnia 28.02.2022r."],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Suplementy diety Zawartość diosminy\nZakres (10 – 600) mg/porcję\nMetoda wysokosprawnej chromatografii cieczowej z detekcją UV-Vis (HPLC/PDA) PB/L-101 wyd. 3 z dnia 28.02.2022r. Suplementy diety Zawartosc diosminy\nZakres (10 – 600) mg/porcje\nMetoda wysokosprawnej chromatografii cieczowej z detekcja UV-Vis (HPLC/PDA) PB/L-101 wyd. 3 z dnia 28.02.2022r.","categories":["pharma"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa00e2","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Suplementy diety","methodology":"Zawartość rutyny","parameters":[{"name":"Zakres","range":"(0,5 – 600) mg/porcję"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją UV-Vis (HPLC/PDA)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją UV-Vis (HPLC/PDA)"],"computed":[],"activity":"Zawartość rutyny\nZakres (0,5 – 600) mg/porcję\nMetoda wysokosprawnej chromatografii cieczowej z detekcją UV-Vis (HPLC/PDA)","reference":"PB/L-102 wyd. 3 z dnia 28.02.2022r.","norm_bases":["PB/L-102 wyd. 3 z dnia 28.02.2022r."],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Suplementy diety Zawartość rutyny\nZakres (0,5 – 600) mg/porcję\nMetoda wysokosprawnej chromatografii cieczowej z detekcją UV-Vis (HPLC/PDA) PB/L-102 wyd. 3 z dnia 28.02.2022r. Suplementy diety Zawartosc rutyny\nZakres (0,5 – 600) mg/porcje\nMetoda wysokosprawnej chromatografii cieczowej z detekcja UV-Vis (HPLC/PDA) PB/L-102 wyd. 3 z dnia 28.02.2022r.","categories":["pharma"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa00e3","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w temp. 22°C w temp. 36°C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w temp. 22°C w temp. 36°C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Biologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w temp. 22°C w temp. 36°C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w temp. 22°C w temp. 36°C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa00e4","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba enterokoków kałowych.","parameters":[],"technique":"Metoda filtracji membranowej;","techniques":["Metoda filtracji membranowej;"],"computed":[],"activity":"Liczba enterokoków kałowych.\nMetoda filtracji membranowej;","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Biologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba enterokoków kałowych.\nMetoda filtracji membranowej; PN-EN ISO 7899-2:2004 Woda do spozycia przez ludzi Liczba enterokokow kalowych.\nMetoda filtracji membranowej; PN-EN ISO 7899-2:2004","categories":["water"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa00e5","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba bakterii Pseudomonas aeruginosa.","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii Pseudomonas aeruginosa.\nMetoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Biologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba bakterii Pseudomonas aeruginosa.\nMetoda filtracji membranowej PN-EN ISO 16266:2009 Woda do spozycia przez ludzi Liczba bakterii Pseudomonas aeruginosa.\nMetoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water","microbiology"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa00e6","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba przetrwalników beztlenowców redukujących siarczyny (Clostridia).","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba przetrwalników beztlenowców redukujących siarczyny (Clostridia).\nMetoda filtracji membranowej","reference":"PN-EN 26461-2:2001","norm_bases":["PN-EN 26461-2:2001"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Biologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba przetrwalników beztlenowców redukujących siarczyny (Clostridia).\nMetoda filtracji membranowej PN-EN 26461-2:2001 Woda do spozycia przez ludzi Liczba przetrwalnikow beztlenowcow redukujacych siarczyny (Clostridia).\nMetoda filtracji membranowej PN-EN 26461-2:2001","categories":["water"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa00e7","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba Clostridium perfringens łącznie ze sporami","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Clostridium perfringens łącznie ze sporami\nMetoda filtracji membranowej","reference":"PN-EN ISO 14189:2016-10","norm_bases":["PN-EN ISO 14189:2016-10"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Biologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba Clostridium perfringens łącznie ze sporami\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10 Woda do spozycia przez ludzi Liczba Clostridium perfringens lacznie ze sporami\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10","categories":["water"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa00e8","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba bakterii z grupy coli.","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii z grupy coli.\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014/A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12","PN-EN ISO 9308-1:2014/A1:2017-04"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Biologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba bakterii z grupy coli.\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014/A1:2017-04 Woda do spozycia przez ludzi Liczba bakterii z grupy coli.\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014/A1:2017-04","categories":["water","microbiology"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa00e9","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba Escherichia coli.","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Escherichia coli.\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014/A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12","PN-EN ISO 9308-1:2014/A1:2017-04"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Biologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba Escherichia coli.\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014/A1:2017-04 Woda do spozycia przez ludzi Liczba Escherichia coli.\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014/A1:2017-04","categories":["water","microbiology"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa00ea","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda ciepła użytkowa","methodology":"Liczba bakterii z rodzaju Legionella, Matryca A: Procedura 5 (pożywka A - BCYE);, Procedura 7 (pożywka C -GVPC);","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii z rodzaju Legionella, Matryca A: Procedura 5 (pożywka A - BCYE);, Procedura 7 (pożywka C -GVPC);\nMetoda filtracji membranowej","reference":"PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08/Ap1:2019-12","norm_bases":["PN-EN ISO 11731:2017-08","PN-EN ISO 11731:2017-08/Ap1:2019-12"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Biologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda ciepła użytkowa Liczba bakterii z rodzaju Legionella, Matryca A: Procedura 5 (pożywka A - BCYE);, Procedura 7 (pożywka C -GVPC);\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08/Ap1:2019-12 Woda ciepla uzytkowa Liczba bakterii z rodzaju Legionella, Matryca A: Procedura 5 (pozywka A - BCYE);, Procedura 7 (pozywka C -GVPC);\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08/Ap1:2019-12","categories":["microbiology","water"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa00eb","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda ciepła użytkowa","methodology":"Pobieranie próbek do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007","norm_bases":["PN-EN ISO 19458:2007"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Biologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda ciepła użytkowa Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 Woda do spozycia przez ludzi, Woda ciepla uzytkowa Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007","categories":["water","microbiology"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa00ec","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-5:2017-10","norm_bases":["PN-ISO 5667-5:2017-10"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-5:2017-10 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-5:2017-10","categories":["water"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa00ed","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Przewodność elektryczna właściwa w 25oC","parameters":[{"name":"Zakres","range":"(100 – 3000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa w 25oC\nZakres (100 – 3000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Przewodność elektryczna właściwa w 25oC\nZakres (100 – 3000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa w 25oC\nZakres (100 – 3000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa00ee","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie rozpuszczonych jonów","parameters":[{"name":"Fluorki","range":"(0,05 – 2,0) mg/l"},{"name":"Chlorki","range":"(0,05 – 250) mg/l"},{"name":"Azotyny","range":"(0,05 – 5,0) mg/l"},{"name":"Azotany","range":"(0,05 – 100) mg/l"},{"name":"Siarczany","range":"(0,05 – 250) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie rozpuszczonych jonów\nZakres:\nFluorki (0,05 – 2,0) mg/l\nChlorki (0,05 – 250) mg/l\nAzotyny (0,05 – 5,0) mg/l\nAzotany (0,05 – 100) mg/l\nSiarczany (0,05 – 250) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie rozpuszczonych jonów\nZakres:\nFluorki (0,05 – 2,0) mg/l\nChlorki (0,05 – 250) mg/l\nAzotyny (0,05 – 5,0) mg/l\nAzotany (0,05 – 100) mg/l\nSiarczany (0,05 – 250) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Woda do spozycia przez ludzi Stezenie rozpuszczonych jonow\nZakres:\nFluorki (0,05 – 2,0) mg/l\nChlorki (0,05 – 250) mg/l\nAzotyny (0,05 – 5,0) mg/l\nAzotany (0,05 – 100) mg/l\nSiarczany (0,05 – 250) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa00ef","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,025 – 2,5) mg/l"}],"technique":"Metoda spektrometryczna","techniques":["Metoda spektrometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,025 – 2,5) mg/l\nMetoda spektrometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie azotu amonowego\nZakres (0,025 – 2,5) mg/l\nMetoda spektrometryczna PN-ISO 7150-1:2002 Woda do spozycia przez ludzi Stezenie azotu amonowego\nZakres (0,025 – 2,5) mg/l\nMetoda spektrometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa00f0","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi pH\nZakres 2,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda do spozycia przez ludzi pH\nZakres 2,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa00f1","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,20 – 100) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,20 – 100) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016","norm_bases":["PN-EN ISO 7027-1:2016"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Mętność\nZakres (0,20 – 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016 Woda do spozycia przez ludzi Metnosc\nZakres (0,20 – 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016","categories":["water"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa00f2","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(2 – 60) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Barwa\nZakres (2 – 60) mg/l Pt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012+Ap1:2015-06 Metoda C","norm_bases":["PN-EN ISO 7887:2012+Ap1:2015-06 Metoda C"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Barwa\nZakres (2 – 60) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012+Ap1:2015-06 Metoda C Woda do spozycia przez ludzi Barwa\nZakres (2 – 60) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012+Ap1:2015-06 Metoda C","categories":["water"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa00f3","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie chloru wolnego","parameters":[{"name":"Zakres","range":"(0,05 – 5,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chloru wolnego\nZakres (0,05 – 5,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7393-2:2018-04","norm_bases":["PN-EN ISO 7393-2:2018-04"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie chloru wolnego\nZakres (0,05 – 5,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 7393-2:2018-04 Woda do spozycia przez ludzi Stezenie chloru wolnego\nZakres (0,05 – 5,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 7393-2:2018-04","categories":["water"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa00f4","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie chloranów, chlorynów","parameters":[{"name":"Chlorany","range":"(0,10 – 1,0) mg/l"},{"name":"Chloryny","range":"(0,10 – 1,0) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie chloranów, chlorynów\nZakres:\nChlorany (0,10 – 1,0) mg/l\nChloryny (0,10 – 1,0) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-4:2022-08","norm_bases":["PN-EN ISO 10304-4:2022-08"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie chloranów, chlorynów\nZakres:\nChlorany (0,10 – 1,0) mg/l\nChloryny (0,10 – 1,0) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-4:2022-08 Woda do spozycia przez ludzi Stezenie chloranow, chlorynow\nZakres:\nChlorany (0,10 – 1,0) mg/l\nChloryny (0,10 – 1,0) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-4:2022-08","categories":["water"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa00f5","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Suma chloranów i chlorynów (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma chloranów i chlorynów (z obliczeń)","reference":"PN-EN ISO 10304-4:2022-08","norm_bases":["PN-EN ISO 10304-4:2022-08"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Suma chloranów i chlorynów (z obliczeń) PN-EN ISO 10304-4:2022-08 Woda do spozycia przez ludzi Suma chloranow i chlorynow (z obliczen) PN-EN ISO 10304-4:2022-08","categories":["water"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa00f6","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie kationów","parameters":[{"name":"Magnez","range":"(1 – 125) mg/l"},{"name":"Sód","range":"(1 – 200) mg/l"},{"name":"Wapń","range":"(2 – 200) mg/l"},{"name":"Jon amonowy","range":"(0,1 – 2,5) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie kationów\nZakres:\nMagnez (1 – 125) mg/l\nSód (1 – 200) mg/l\nWapń (2 – 200) mg/l\nJon amonowy (0,1 – 2,5) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 14911:2002","norm_bases":["PN-EN ISO 14911:2002"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie kationów\nZakres:\nMagnez (1 – 125) mg/l\nSód (1 – 200) mg/l\nWapń (2 – 200) mg/l\nJon amonowy (0,1 – 2,5) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 14911:2002 Woda do spozycia przez ludzi Stezenie kationow\nZakres:\nMagnez (1 – 125) mg/l\nSod (1 – 200) mg/l\nWapn (2 – 200) mg/l\nJon amonowy (0,1 – 2,5) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 14911:2002","categories":["water"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa00f7","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Sumaryczna zawartość wapnia i magnezu – twardość ogólna (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Sumaryczna zawartość wapnia i magnezu – twardość ogólna (z obliczeń)","reference":"PN-EN ISO 14911:2002","norm_bases":["PN-EN ISO 14911:2002"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Sumaryczna zawartość wapnia i magnezu – twardość ogólna (z obliczeń) PN-EN ISO 14911:2002 Woda do spozycia przez ludzi Sumaryczna zawartosc wapnia i magnezu – twardosc ogolna (z obliczen) PN-EN ISO 14911:2002","categories":["water"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa00f8","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie cyjanków ogólnych","parameters":[{"name":"Zakres","range":"(5,0 – 100) μg/l"}],"technique":"Metoda analizy przepływowej ciągłej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda analizy przepływowej ciągłej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie cyjanków ogólnych\nZakres (5,0 – 100) μg/l\nMetoda analizy przepływowej ciągłej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 14403-2:2012","norm_bases":["PN-EN ISO 14403-2:2012"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie cyjanków ogólnych\nZakres (5,0 – 100) μg/l\nMetoda analizy przepływowej ciągłej (CFA) z detekcją spektrofotometryczną PN-EN ISO 14403-2:2012 Woda do spozycia przez ludzi Stezenie cyjankow ogolnych\nZakres (5,0 – 100) μg/l\nMetoda analizy przeplywowej ciaglej (CFA) z detekcja spektrofotometryczna PN-EN ISO 14403-2:2012","categories":["water"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa00f9","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Wartość indeksu nadmanganianowego","parameters":[{"name":"Zakres","range":"(0,50 – 10) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Wartość indeksu nadmanganianowego\nZakres (0,50 – 10) mg/l O2\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Wartość indeksu nadmanganianowego\nZakres (0,50 – 10) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda do spozycia przez ludzi Wartosc indeksu nadmanganianowego\nZakres (0,50 – 10) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa00fa","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie związków organicznych","parameters":[{"name":"Benzen","range":"(0,2 – 20) μg/l"},{"name":"Zakres","range":"1,2-dichloroetan (0,2 – 20) μg/l"},{"name":"Trichloroeten","range":"(0,2 – 20) μg/l"},{"name":"Tetrachloroeten","range":"(0,2 – 20) μg/l"}],"technique":"Metoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją spektrometrią mas (P&T GC-MS)","techniques":["Metoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją spektrometrią mas (P&T GC-MS)"],"computed":[],"activity":"Stężenie związków organicznych\nZakres:\nBenzen (0,2 – 20) μg/l\nZakres 1,2-dichloroetan (0,2 – 20) μg/l\nTrichloroeten (0,2 – 20) μg/l\nTetrachloroeten (0,2 – 20) μg/l\nMetoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją spektrometrią mas (P&T GC-MS)","reference":"PN-EN ISO 15680:2008","norm_bases":["PN-EN ISO 15680:2008"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie związków organicznych\nZakres:\nBenzen (0,2 – 20) μg/l\nZakres 1,2-dichloroetan (0,2 – 20) μg/l\nTrichloroeten (0,2 – 20) μg/l\nTetrachloroeten (0,2 – 20) μg/l\nMetoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją spektrometrią mas (P&T GC-MS) PN-EN ISO 15680:2008 Woda do spozycia przez ludzi Stezenie zwiazkow organicznych\nZakres:\nBenzen (0,2 – 20) μg/l\nZakres 1,2-dichloroetan (0,2 – 20) μg/l\nTrichloroeten (0,2 – 20) μg/l\nTetrachloroeten (0,2 – 20) μg/l\nMetoda chromatografii gazowej z technika wylapywania i wyplukiwania (Purge&Trap) i detekcja spektrometria mas (P&T GC-MS) PN-EN ISO 15680:2008","categories":["water"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa00fb","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Suma trichloroetenu i tetrachloroetenu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma trichloroetenu i tetrachloroetenu (z obliczeń)","reference":"PN-EN ISO 15680:2008","norm_bases":["PN-EN ISO 15680:2008"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Suma trichloroetenu i tetrachloroetenu (z obliczeń) PN-EN ISO 15680:2008 Woda do spozycia przez ludzi Suma trichloroetenu i tetrachloroetenu (z obliczen) PN-EN ISO 15680:2008","categories":["water"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa00fc","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda na pływalniach","methodology":"Stężenie trihalometanów (THM) Zakres:","parameters":[{"name":"Trichlorometan (chloroform) (2,0 – 300) μg/l"},{"name":"Bromodichlorometan (2,0 – 150) μg/l"},{"name":"Dibromochlorometan (2,0 – 150) μg/l"},{"name":"Tribromometan (bromoform) (2,0 – 150) μg/l"}],"technique":"Metoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją spektrometrią mas (P&T GC-MS)","techniques":["Metoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją spektrometrią mas (P&T GC-MS)"],"computed":[],"activity":"Stężenie trihalometanów (THM) Zakres:\nZakres:\nTrichlorometan (chloroform) (2,0 – 300) μg/l\nBromodichlorometan (2,0 – 150) μg/l\nDibromochlorometan (2,0 – 150) μg/l\nTribromometan (bromoform) (2,0 – 150) μg/l\nMetoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją spektrometrią mas (P&T GC-MS)","reference":"PN-EN ISO 15680:2008","norm_bases":["PN-EN ISO 15680:2008"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda na pływalniach Stężenie trihalometanów (THM) Zakres:\nZakres:\nTrichlorometan (chloroform) (2,0 – 300) μg/l\nBromodichlorometan (2,0 – 150) μg/l\nDibromochlorometan (2,0 – 150) μg/l\nTribromometan (bromoform) (2,0 – 150) μg/l\nMetoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją spektrometrią mas (P&T GC-MS) PN-EN ISO 15680:2008 Woda do spozycia przez ludzi, Woda na plywalniach Stezenie trihalometanow (THM) Zakres:\nZakres:\nTrichlorometan (chloroform) (2,0 – 300) μg/l\nBromodichlorometan (2,0 – 150) μg/l\nDibromochlorometan (2,0 – 150) μg/l\nTribromometan (bromoform) (2,0 – 150) μg/l\nMetoda chromatografii gazowej z technika wylapywania i wyplukiwania (Purge&Trap) i detekcja spektrometria mas (P&T GC-MS) PN-EN ISO 15680:2008","categories":["water"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa00fd","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda na pływalniach","methodology":"Suma stężeń trihalometanów (THM) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma stężeń trihalometanów (THM) (z obliczeń)","reference":"PN-EN ISO 15680:2008","norm_bases":["PN-EN ISO 15680:2008"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda na pływalniach Suma stężeń trihalometanów (THM) (z obliczeń) PN-EN ISO 15680:2008 Woda do spozycia przez ludzi, Woda na plywalniach Suma stezen trihalometanow (THM) (z obliczen) PN-EN ISO 15680:2008","categories":["water"],"row_index":55,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa00fe","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)","parameters":[{"name":"Benzo(a)piren","range":"(0,0018 - 0,05) μg/l"},{"name":"Benzo(b)fluoranten","range":"(0,0014 - 0,05) μg/l"},{"name":"Benzo(k)fluoranten","range":"(0,0009 - 0,05) μg/l"},{"name":"Benzo(ghi)perylen","range":"(0,0028 - 0,05) μg/l"},{"name":"Indeno(1,2,3-cd)piren","range":"(0,0024 - 0,05) μg/l"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC – FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC – FLD)"],"computed":[],"activity":"Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)\nZakres:\nBenzo(a)piren (0,0018 - 0,05) μg/l\nBenzo(b)fluoranten (0,0014 - 0,05) μg/l\nBenzo(k)fluoranten (0,0009 - 0,05) μg/l\nBenzo(ghi)perylen (0,0028 - 0,05) μg/l\nIndeno(1,2,3-cd)piren (0,0024 - 0,05) μg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC – FLD)","reference":"PB/L-82 wydanie 1 z dnia 11.04.2012r.","norm_bases":["PB/L-82 wydanie 1 z dnia 11.04.2012r."],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Fizykochemicznych; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)\nZakres:\nBenzo(a)piren (0,0018 - 0,05) μg/l\nBenzo(b)fluoranten (0,0014 - 0,05) μg/l\nBenzo(k)fluoranten (0,0009 - 0,05) μg/l\nBenzo(ghi)perylen (0,0028 - 0,05) μg/l\nIndeno(1,2,3-cd)piren (0,0024 - 0,05) μg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC – FLD) PB/L-82 wydanie 1 z dnia 11.04.2012r. Woda do spozycia przez ludzi Stezenie wielopierscieniowych weglowodorow aromatycznych (WWA)\nZakres:\nBenzo(a)piren (0,0018 - 0,05) μg/l\nBenzo(b)fluoranten (0,0014 - 0,05) μg/l\nBenzo(k)fluoranten (0,0009 - 0,05) μg/l\nBenzo(ghi)perylen (0,0028 - 0,05) μg/l\nIndeno(1,2,3-cd)piren (0,0024 - 0,05) μg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC – FLD) PB/L-82 wydanie 1 z dnia 11.04.2012r.","categories":["water"],"row_index":56,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa00ff","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Suma stężeń: Benzo(b)fluorantenu, Benzo(k)fluorantenu, Benzo(ghi)perylenu, Indeno(1,2,3-cd)pirenu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma stężeń: Benzo(b)fluorantenu, Benzo(k)fluorantenu, Benzo(ghi)perylenu, Indeno(1,2,3-cd)pirenu (z obliczeń)","reference":"PB/L-82 wydanie 1 z dnia 11.04.2012r.","norm_bases":["PB/L-82 wydanie 1 z dnia 11.04.2012r."],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Fizykochemicznych; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Suma stężeń: Benzo(b)fluorantenu, Benzo(k)fluorantenu, Benzo(ghi)perylenu, Indeno(1,2,3-cd)pirenu (z obliczeń) PB/L-82 wydanie 1 z dnia 11.04.2012r. Woda do spozycia przez ludzi Suma stezen: Benzo(b)fluorantenu, Benzo(k)fluorantenu, Benzo(ghi)perylenu, Indeno(1,2,3-cd)pirenu (z obliczen) PB/L-82 wydanie 1 z dnia 11.04.2012r.","categories":["water"],"row_index":57,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa0100","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie rtęci","parameters":[{"name":"Zakres","range":"(0,0005 – 0,01) mg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)"],"computed":[],"activity":"Stężenie rtęci\nZakres (0,0005 – 0,01) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"PB/L-01 wydanie 5 z dnia 16.07.2021 r.","norm_bases":["PB/L-01 wydanie 5 z dnia 16.07.2021 r."],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Fizykochemicznych; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie rtęci\nZakres (0,0005 – 0,01) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PB/L-01 wydanie 5 z dnia 16.07.2021 r. Woda do spozycia przez ludzi Stezenie rteci\nZakres (0,0005 – 0,01) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PB/L-01 wydanie 5 z dnia 16.07.2021 r.","categories":["water"],"row_index":58,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa0101","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie metali","parameters":[{"name":"Bor","range":"(10,0-5000) μg/l"},{"name":"Glin","range":"(10,0-5000) μg/l"},{"name":"Chrom","range":"(1,0-100) μg/l"},{"name":"Mangan","range":"(10,0-10000) μg/l"},{"name":"Żelazo","range":"(10,0-25000) μg/l"},{"name":"Nikiel","range":"(1,0-100) μg/l"},{"name":"Miedź","range":"(10,0-5000) μg/l"},{"name":"Arsen","range":"(1,0-100) μg/l"},{"name":"Selen","range":"(1,0-100) μg/l"},{"name":"Kadm","range":"(1,0-100) μg/l"},{"name":"Antymon","range":"(1,0-100) μg/l"},{"name":"Ołów","range":"(1,0-100) μg/l"},{"name":"Uran","range":"(1,0-100) μg/l"},{"name":"Srebro","range":"(1,0-100) μg/l"}],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"computed":[],"activity":"Stężenie metali\nZakres:\nBor (10,0-5000) μg/l\nGlin (10,0-5000) μg/l\nChrom (1,0-100) μg/l\nMangan (10,0-10000) μg/l\nŻelazo (10,0-25000) μg/l\nNikiel (1,0-100) μg/l\nMiedź (10,0-5000) μg/l\nArsen (1,0-100) μg/l\nSelen (1,0-100) μg/l\nKadm (1,0-100) μg/l\nAntymon (1,0-100) μg/l\nOłów (1,0-100) μg/l\nUran (1,0-100) μg/l\nSrebro (1,0-100) μg/l\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"PN-EN ISO 17294-2:2024-04","norm_bases":["PN-EN ISO 17294-2:2024-04"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Fizykochemicznych; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie metali\nZakres:\nBor (10,0-5000) μg/l\nGlin (10,0-5000) μg/l\nChrom (1,0-100) μg/l\nMangan (10,0-10000) μg/l\nŻelazo (10,0-25000) μg/l\nNikiel (1,0-100) μg/l\nMiedź (10,0-5000) μg/l\nArsen (1,0-100) μg/l\nSelen (1,0-100) μg/l\nKadm (1,0-100) μg/l\nAntymon (1,0-100) μg/l\nOłów (1,0-100) μg/l\nUran (1,0-100) μg/l\nSrebro (1,0-100) μg/l\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) PN-EN ISO 17294-2:2024-04 Woda do spozycia przez ludzi Stezenie metali\nZakres:\nBor (10,0-5000) μg/l\nGlin (10,0-5000) μg/l\nChrom (1,0-100) μg/l\nMangan (10,0-10000) μg/l\nZelazo (10,0-25000) μg/l\nNikiel (1,0-100) μg/l\nMiedz (10,0-5000) μg/l\nArsen (1,0-100) μg/l\nSelen (1,0-100) μg/l\nKadm (1,0-100) μg/l\nAntymon (1,0-100) μg/l\nOlow (1,0-100) μg/l\nUran (1,0-100) μg/l\nSrebro (1,0-100) μg/l\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) PN-EN ISO 17294-2:2024-04","categories":["materials","water"],"row_index":59,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa0102","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pozostałość pestycydów","parameters":[{"name":"Acefat","range":"(0,03-0,50) μg/l"},{"name":"Acetamipryd","range":"(0,03-0,50) μg/l"},{"name":"Atrazyna","range":"(0,03-0,50) μg/l"},{"name":"Azinfos etylowy","range":"(0,10-0,50) μg/l"},{"name":"Azinfos metylowy","range":"(0,10-0,50) μg/l"},{"name":"Azoksystrobina","range":"(0,03-0,50) μg/l"},{"name":"Chlorantraniliprol","range":"(0,03-0,50) μg/l"},{"name":"Chlorotoluron","range":"(0,03-0,50) μg/l"},{"name":"Cyjazofamid","range":"(0,10-0,50) μg/l"},{"name":"Diflubenzuron","range":"(0,05-0,50) μg/l"},{"name":"Dimetoat","range":"(0,03-0,50) μg/l"},{"name":"Dimetomorf","range":"(0,03-0,50) μg/l"},{"name":"Ditianon","range":"(0,05-0,50) μg/l"},{"name":"Etirimol","range":"(0,03-0,50) μg/l"},{"name":"Fipronil","range":"(0,03-0,50) μg/l"},{"name":"Fipronil sulfon","range":"(0,03-0,50) μg/l"},{"name":"Fluazifop (free acide)","range":"(0,10-0,50) μg/l"},{"name":"Fluoksastrobina","range":"(0,03-0,50) μg/l"},{"name":"Flutolanil","range":"(0,03-0,50) μg/l"},{"name":"Flusulfamid","range":"(0,03-0,50) μg/l"},{"name":"Foksym","range":"(0,10-0,50) μg/l"},{"name":"Formetanat","range":"(0,03-0,50) μg/l"},{"name":"Fosmet","range":"(0,10-0,50) μg/l"},{"name":"Fosmetu oxon","range":"(0,03-0,50) μg/l"},{"name":"Heksytiazoks","range":"(0,03-0,50) μg/l"},{"name":"Imidaklopryd","range":"(0,03-0,50) μg/l"},{"name":"Iprowalikarb","range":"(0,03-0,50) μg/l"},{"name":"Izoproturon","range":"(0,03-0,50) μg/l"},{"name":"Karbalyl","range":"(0,03-0,50) μg/l"},{"name":"Karbendazim","range":"(0,03-0,50) μg/l"},{"name":"Klotianidyna","range":"(0,10-0,50) μg/l"},{"name":"Lenacil","range":"(0,10-0,50) μg/l"},{"name":"Linuron","range":"(0,10-0,50) μg/l"},{"name":"Mandipropanid","range":"(0,10-0,50) μg/l"},{"name":"Mepanipirym","range":"(0,05-0,50) μg/l"},{"name":"Metamidofos","range":"(0,03-0,50) μg/l"},{"name":"Metalaksyl","range":"(0,03-0,50) μg/l"},{"name":"Metobromuron","range":"(0,10-0,50) μg/l"},{"name":"Metiokarb","range":"(0,05-0,50) μg/l"},{"name":"Metiokarbu sulfon","range":"(0,05-0,50) μg/l"},{"name":"Metiokarbu sulfotlenek"},{"name":"Zakres","range":"(0,03-0,50) μg/l"},{"name":"Metoksyfenozyd","range":"(0,03-0,50) μg/l"},{"name":"Metomyl","range":"(0,05-0,50) μg/l"},{"name":"Nitenpyram","range":"(0,10-0,50) μg/l"},{"name":"Okadiksyl","range":"(0,03-0,50) μg/l"},{"name":"Oksydemeton metylowy","range":"(0,03-0,50) μg/l"},{"name":"Ometoat","range":"(0,03-0,50) μg/l"}],"technique":"Metoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC/MS/MS)","techniques":["Metoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC/MS/MS)"],"computed":[],"activity":"Pozostałość pestycydów\nZakres:\nAcefat (0,03-0,50) μg/l\nAcetamipryd (0,03-0,50) μg/l\nAtrazyna (0,03-0,50) μg/l\nAzinfos etylowy (0,10-0,50) μg/l\nAzinfos metylowy (0,10-0,50) μg/l\nAzoksystrobina (0,03-0,50) μg/l\nChlorantraniliprol (0,03-0,50) μg/l\nChlorotoluron (0,03-0,50) μg/l\nCyjazofamid (0,10-0,50) μg/l\nDiflubenzuron (0,05-0,50) μg/l\nDimetoat (0,03-0,50) μg/l\nDimetomorf (0,03-0,50) μg/l\nDitianon (0,05-0,50) μg/l\nEtirimol (0,03-0,50) μg/l\nFipronil (0,03-0,50) μg/l\nFipronil sulfon (0,03-0,50) μg/l\nFluazifop (free acide) (0,10-0,50) μg/l\nFluoksastrobina (0,03-0,50) μg/l\nFlutolanil (0,03-0,50) μg/l\nFlusulfamid (0,03-0,50) μg/l\nFoksym (0,10-0,50) μg/l\nFormetanat (0,03-0,50) μg/l\nFosmet (0,10-0,50) μg/l\nFosmetu oxon (0,03-0,50) μg/l\nHeksytiazoks (0,03-0,50) μg/l\nImidaklopryd (0,03-0,50) μg/l\nIprowalikarb (0,03-0,50) μg/l\nIzoproturon (0,03-0,50) μg/l\nKarbalyl (0,03-0,50) μg/l\nKarbendazim (0,03-0,50) μg/l\nKlotianidyna (0,10-0,50) μg/l\nLenacil (0,10-0,50) μg/l\nLinuron (0,10-0,50) μg/l\nMandipropanid (0,10-0,50) μg/l\nMepanipirym (0,05-0,50) μg/l\nMetamidofos (0,03-0,50) μg/l\nMetalaksyl (0,03-0,50) μg/l\nMetobromuron (0,10-0,50) μg/l\nMetiokarb (0,05-0,50) μg/l\nMetiokarbu sulfon (0,05-0,50) μg/l\nMetiokarbu sulfotlenek\nZakres (0,03-0,50) μg/l\nMetoksyfenozyd (0,03-0,50) μg/l\nMetomyl (0,05-0,50) μg/l\nNitenpyram (0,10-0,50) μg/l\nOkadiksyl (0,03-0,50) μg/l\nOksydemeton metylowy (0,03-0,50) μg/l\nOmetoat (0,03-0,50) μg/l\nMetoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC/MS/MS)","reference":"PB/L – 107 wyd.1 z dnia 17.04.2020 r.","norm_bases":["PB/L – 107 wyd.1 z dnia 17.04.2020 r."],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Fizykochemicznych; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pozostałość pestycydów\nZakres:\nAcefat (0,03-0,50) μg/l\nAcetamipryd (0,03-0,50) μg/l\nAtrazyna (0,03-0,50) μg/l\nAzinfos etylowy (0,10-0,50) μg/l\nAzinfos metylowy (0,10-0,50) μg/l\nAzoksystrobina (0,03-0,50) μg/l\nChlorantraniliprol (0,03-0,50) μg/l\nChlorotoluron (0,03-0,50) μg/l\nCyjazofamid (0,10-0,50) μg/l\nDiflubenzuron (0,05-0,50) μg/l\nDimetoat (0,03-0,50) μg/l\nDimetomorf (0,03-0,50) μg/l\nDitianon (0,05-0,50) μg/l\nEtirimol (0,03-0,50) μg/l\nFipronil (0,03-0,50) μg/l\nFipronil sulfon (0,03-0,50) μg/l\nFluazifop (free acide) (0,10-0,50) μg/l\nFluoksastrobina (0,03-0,50) μg/l\nFlutolanil (0,03-0,50) μg/l\nFlusulfamid (0,03-0,50) μg/l\nFoksym (0,10-0,50) μg/l\nFormetanat (0,03-0,50) μg/l\nFosmet (0,10-0,50) μg/l\nFosmetu oxon (0,03-0,50) μg/l\nHeksytiazoks (0,03-0,50) μg/l\nImidaklopryd (0,03-0,50) μg/l\nIprowalikarb (0,03-0,50) μg/l\nIzoproturon (0,03-0,50) μg/l\nKarbalyl (0,03-0,50) μg/l\nKarbendazim (0,03-0,50) μg/l\nKlotianidyna (0,10-0,50) μg/l\nLenacil (0,10-0,50) μg/l\nLinuron (0,10-0,50) μg/l\nMandipropanid (0,10-0,50) μg/l\nMepanipirym (0,05-0,50) μg/l\nMetamidofos (0,03-0,50) μg/l\nMetalaksyl (0,03-0,50) μg/l\nMetobromuron (0,10-0,50) μg/l\nMetiokarb (0,05-0,50) μg/l\nMetiokarbu sulfon (0,05-0,50) μg/l\nMetiokarbu sulfotlenek\nZakres (0,03-0,50) μg/l\nMetoksyfenozyd (0,03-0,50) μg/l\nMetomyl (0,05-0,50) μg/l\nNitenpyram (0,10-0,50) μg/l\nOkadiksyl (0,03-0,50) μg/l\nOksydemeton metylowy (0,03-0,50) μg/l\nOmetoat (0,03-0,50) μg/l\nMetoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC/MS/MS) PB/L – 107 wyd.1 z dnia 17.04.2020 r. Woda do spozycia przez ludzi Pozostalosc pestycydow\nZakres:\nAcefat (0,03-0,50) μg/l\nAcetamipryd (0,03-0,50) μg/l\nAtrazyna (0,03-0,50) μg/l\nAzinfos etylowy (0,10-0,50) μg/l\nAzinfos metylowy (0,10-0,50) μg/l\nAzoksystrobina (0,03-0,50) μg/l\nChlorantraniliprol (0,03-0,50) μg/l\nChlorotoluron (0,03-0,50) μg/l\nCyjazofamid (0,10-0,50) μg/l\nDiflubenzuron (0,05-0,50) μg/l\nDimetoat (0,03-0,50) μg/l\nDimetomorf (0,03-0,50) μg/l\nDitianon (0,05-0,50) μg/l\nEtirimol (0,03-0,50) μg/l\nFipronil (0,03-0,50) μg/l\nFipronil sulfon (0,03-0,50) μg/l\nFluazifop (free acide) (0,10-0,50) μg/l\nFluoksastrobina (0,03-0,50) μg/l\nFlutolanil (0,03-0,50) μg/l\nFlusulfamid (0,03-0,50) μg/l\nFoksym (0,10-0,50) μg/l\nFormetanat (0,03-0,50) μg/l\nFosmet (0,10-0,50) μg/l\nFosmetu oxon (0,03-0,50) μg/l\nHeksytiazoks (0,03-0,50) μg/l\nImidaklopryd (0,03-0,50) μg/l\nIprowalikarb (0,03-0,50) μg/l\nIzoproturon (0,03-0,50) μg/l\nKarbalyl (0,03-0,50) μg/l\nKarbendazim (0,03-0,50) μg/l\nKlotianidyna (0,10-0,50) μg/l\nLenacil (0,10-0,50) μg/l\nLinuron (0,10-0,50) μg/l\nMandipropanid (0,10-0,50) μg/l\nMepanipirym (0,05-0,50) μg/l\nMetamidofos (0,03-0,50) μg/l\nMetalaksyl (0,03-0,50) μg/l\nMetobromuron (0,10-0,50) μg/l\nMetiokarb (0,05-0,50) μg/l\nMetiokarbu sulfon (0,05-0,50) μg/l\nMetiokarbu sulfotlenek\nZakres (0,03-0,50) μg/l\nMetoksyfenozyd (0,03-0,50) μg/l\nMetomyl (0,05-0,50) μg/l\nNitenpyram (0,10-0,50) μg/l\nOkadiksyl (0,03-0,50) μg/l\nOksydemeton metylowy (0,03-0,50) μg/l\nOmetoat (0,03-0,50) μg/l\nMetoda chromatografii cieczowej z detekcja tandemowa spektrometria mas (LC/MS/MS) PB/L – 107 wyd.1 z dnia 17.04.2020 r.","categories":["water"],"row_index":60,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa0103","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pozostałość pestycydów","parameters":[{"name":"Pencykuron","range":"(0,03-0,50) μg/l"},{"name":"Pimetrozyna","range":"(0,03-0,50) μg/l"},{"name":"Piryproksyfen","range":"(0,03-0,50) μg/l"},{"name":"Piraklostrobina","range":"(0,03-0,50) μg/l"},{"name":"Propamokarb","range":"(0,03-0,50) μg/l"},{"name":"Spiroksamina","range":"(0,03-0,50) μg/l"},{"name":"Tebufenozyd","range":"(0,05-0,50) μg/l"},{"name":"Tebufenpyrad","range":"(0,03-0,50) μg/l"},{"name":"Tetrakonazol","range":"(0,03-0,50) μg/l"},{"name":"Tiabendazol","range":"(0,03-0,50) μg/l"},{"name":"Tiodikarb","range":"(0,05-0,50) μg/l"},{"name":"Trifloksystrobina","range":"(0,03-0,50) μg/l"},{"name":"Tiametoksam","range":"(0,03-0,50) μg/l"},{"name":"Tiaklopryd","range":"(0,03-0,50) μg/l"},{"name":"Tiofanat metylu","range":"(0,03-0,50) μg/l"},{"name":"Forat oxon sulfon","range":"(0,03-0,50) μg/l"},{"name":"Forat sulfon","range":"(0,05-0,50) μg/l"},{"name":"Forat sulfotlenek","range":"(0,03-0,50) μg/l"},{"name":"Forat oxon","range":"(0,05-0,50) μg/l"}],"technique":"Metoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC/MS/MS)","techniques":["Metoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC/MS/MS)"],"computed":[],"activity":"Pozostałość pestycydów\nZakres:\nPencykuron (0,03-0,50) μg/l\nPimetrozyna (0,03-0,50) μg/l\nPiryproksyfen (0,03-0,50) μg/l\nPiraklostrobina (0,03-0,50) μg/l\nPropamokarb (0,03-0,50) μg/l\nSpiroksamina (0,03-0,50) μg/l\nTebufenozyd (0,05-0,50) μg/l\nTebufenpyrad (0,03-0,50) μg/l\nTetrakonazol (0,03-0,50) μg/l\nTiabendazol (0,03-0,50) μg/l\nTiodikarb (0,05-0,50) μg/l\nTrifloksystrobina (0,03-0,50) μg/l\nTiametoksam (0,03-0,50) μg/l\nTiaklopryd (0,03-0,50) μg/l\nTiofanat metylu (0,03-0,50) μg/l\nForat oxon sulfon (0,03-0,50) μg/l\nForat sulfon (0,05-0,50) μg/l\nForat sulfotlenek (0,03-0,50) μg/l\nForat oxon (0,05-0,50) μg/l\nMetoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC/MS/MS)","reference":"PB/L – 107 wyd.1 z dnia 17.04.2020 r.","norm_bases":["PB/L – 107 wyd.1 z dnia 17.04.2020 r."],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Fizykochemicznych; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pozostałość pestycydów\nZakres:\nPencykuron (0,03-0,50) μg/l\nPimetrozyna (0,03-0,50) μg/l\nPiryproksyfen (0,03-0,50) μg/l\nPiraklostrobina (0,03-0,50) μg/l\nPropamokarb (0,03-0,50) μg/l\nSpiroksamina (0,03-0,50) μg/l\nTebufenozyd (0,05-0,50) μg/l\nTebufenpyrad (0,03-0,50) μg/l\nTetrakonazol (0,03-0,50) μg/l\nTiabendazol (0,03-0,50) μg/l\nTiodikarb (0,05-0,50) μg/l\nTrifloksystrobina (0,03-0,50) μg/l\nTiametoksam (0,03-0,50) μg/l\nTiaklopryd (0,03-0,50) μg/l\nTiofanat metylu (0,03-0,50) μg/l\nForat oxon sulfon (0,03-0,50) μg/l\nForat sulfon (0,05-0,50) μg/l\nForat sulfotlenek (0,03-0,50) μg/l\nForat oxon (0,05-0,50) μg/l\nMetoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC/MS/MS) PB/L – 107 wyd.1 z dnia 17.04.2020 r. Woda do spozycia przez ludzi Pozostalosc pestycydow\nZakres:\nPencykuron (0,03-0,50) μg/l\nPimetrozyna (0,03-0,50) μg/l\nPiryproksyfen (0,03-0,50) μg/l\nPiraklostrobina (0,03-0,50) μg/l\nPropamokarb (0,03-0,50) μg/l\nSpiroksamina (0,03-0,50) μg/l\nTebufenozyd (0,05-0,50) μg/l\nTebufenpyrad (0,03-0,50) μg/l\nTetrakonazol (0,03-0,50) μg/l\nTiabendazol (0,03-0,50) μg/l\nTiodikarb (0,05-0,50) μg/l\nTrifloksystrobina (0,03-0,50) μg/l\nTiametoksam (0,03-0,50) μg/l\nTiaklopryd (0,03-0,50) μg/l\nTiofanat metylu (0,03-0,50) μg/l\nForat oxon sulfon (0,03-0,50) μg/l\nForat sulfon (0,05-0,50) μg/l\nForat sulfotlenek (0,03-0,50) μg/l\nForat oxon (0,05-0,50) μg/l\nMetoda chromatografii cieczowej z detekcja tandemowa spektrometria mas (LC/MS/MS) PB/L – 107 wyd.1 z dnia 17.04.2020 r.","categories":["water"],"row_index":61,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa0104","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Suma pestycydów (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma pestycydów (z obliczeń)","reference":"PB/L – 107 wyd.1 z dnia 17.04.2020 r.","norm_bases":["PB/L – 107 wyd.1 z dnia 17.04.2020 r."],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Fizykochemicznych; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Suma pestycydów (z obliczeń) PB/L – 107 wyd.1 z dnia 17.04.2020 r. Woda do spozycia przez ludzi Suma pestycydow (z obliczen) PB/L – 107 wyd.1 z dnia 17.04.2020 r.","categories":["water"],"row_index":62,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa0105","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-5:2017-10","norm_bases":["PN-ISO 5667-5:2017-10"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-5:2017-10 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-5:2017-10","categories":["water"],"row_index":63,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa0106","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie azotynów","parameters":[{"name":"Zakres","range":"(0,010 – 1,5) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotynów\nZakres (0,010 – 1,5) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie azotynów\nZakres (0,010 – 1,5) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, Woda do spozycia przez ludzi Stezenie azotynow\nZakres (0,010 – 1,5) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":64,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa0107","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(148 – 1410) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (148 – 1410) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Przewodność elektryczna właściwa\nZakres (148 – 1410) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, Woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa\nZakres (148 – 1410) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":65,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa0108","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie jonu amonowego","parameters":[{"name":"Zakres","range":"(0,030 – 5,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie jonu amonowego\nZakres (0,030 – 5,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie jonu amonowego\nZakres (0,030 – 5,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, Woda do spozycia przez ludzi Stezenie jonu amonowego\nZakres (0,030 – 5,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":66,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa0109","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie azotanów","parameters":[{"name":"Zakres","range":"(0,90 – 60) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotanów\nZakres (0,90 – 60) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576.08","norm_bases":["PN-82/C-04576.08"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie azotanów\nZakres (0,90 – 60) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08 Woda, Woda do spozycia przez ludzi Stezenie azotanow\nZakres (0,90 – 60) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08","categories":["water"],"row_index":67,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa010a","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"pH","parameters":[{"name":"Zakres","range":"3,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 3,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi pH\nZakres 3,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, Woda do spozycia przez ludzi pH\nZakres 3,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":68,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa010b","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,10 – 1000) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,10 – 1000) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Mętność\nZakres (0,10 – 1000) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda, Woda do spozycia przez ludzi Metnosc\nZakres (0,10 – 1000) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":69,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa010c","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(5,0 – 40) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Barwa\nZakres (5,0 – 40) mg/l Pt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012+Ap1:2015-06 pkt 6","norm_bases":["PN-EN ISO 7887:2012+Ap1:2015-06 pkt 6"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Barwa\nZakres (5,0 – 40) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012+Ap1:2015-06 pkt 6 Woda, Woda do spozycia przez ludzi Barwa\nZakres (5,0 – 40) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012+Ap1:2015-06 pkt 6","categories":["water"],"row_index":70,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa010d","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie fluorków","parameters":[{"name":"Zakres","range":"(0,10 – 4,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fluorków\nZakres (0,10 – 4,0) mg/l\nMetoda spektrofotometryczna","reference":"PB/L-115, wyd.1 z 09.02.2026 r. | na podstawie metody Hach nr 8029","norm_bases":["PB/L-115, wyd.1 z 09.02.2026 r.","na podstawie metody Hach nr 8029"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie fluorków\nZakres (0,10 – 4,0) mg/l\nMetoda spektrofotometryczna PB/L-115, wyd.1 z 09.02.2026 r. | na podstawie metody Hach nr 8029 Woda, Woda do spozycia przez ludzi Stezenie fluorkow\nZakres (0,10 – 4,0) mg/l\nMetoda spektrofotometryczna PB/L-115, wyd.1 z 09.02.2026 r. | na podstawie metody Hach nr 8029","categories":["water"],"row_index":71,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa010e","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie chloru wolnego","parameters":[{"name":"Zakres","range":"(0,050 – 4,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chloru wolnego\nZakres (0,050 – 4,0) mg/l\nMetoda spektrofotometryczna","reference":"PB/L-116, wyd. 1 z 09.02.2026 r. | na podstawie metody Hach nr 8021","norm_bases":["PB/L-116, wyd. 1 z 09.02.2026 r.","na podstawie metody Hach nr 8021"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie chloru wolnego\nZakres (0,050 – 4,0) mg/l\nMetoda spektrofotometryczna PB/L-116, wyd. 1 z 09.02.2026 r. | na podstawie metody Hach nr 8021 Woda, Woda do spozycia przez ludzi Stezenie chloru wolnego\nZakres (0,050 – 4,0) mg/l\nMetoda spektrofotometryczna PB/L-116, wyd. 1 z 09.02.2026 r. | na podstawie metody Hach nr 8021","categories":["water"],"row_index":72,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa010f","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(10 – 350) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie siarczanów\nZakres (10 – 350) mg/l\nMetoda spektrofotometryczna","reference":"PB/L-117, wyd. 1 z 09.02.2026 r. | na podstawie metody Hach nr 8051","norm_bases":["PB/L-117, wyd. 1 z 09.02.2026 r.","na podstawie metody Hach nr 8051"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie siarczanów\nZakres (10 – 350) mg/l\nMetoda spektrofotometryczna PB/L-117, wyd. 1 z 09.02.2026 r. | na podstawie metody Hach nr 8051 Woda, Woda do spozycia przez ludzi Stezenie siarczanow\nZakres (10 – 350) mg/l\nMetoda spektrofotometryczna PB/L-117, wyd. 1 z 09.02.2026 r. | na podstawie metody Hach nr 8051","categories":["water"],"row_index":73,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa0110","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5,0 – 400) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5,0 – 400) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie chlorków\nZakres (5,0 – 400) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda, Woda do spozycia przez ludzi Stezenie chlorkow\nZakres (5,0 – 400) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":74,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa0111","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie glinu","parameters":[{"name":"Zakres","range":"(0,020 – 0,25) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie glinu\nZakres (0,020 – 0,25) mg/l\nMetoda spektrofotometryczna","reference":"PB/L-118, wyd. 1 z 09.02.2026 r. | na podstawie metody Hach nr 8326","norm_bases":["PB/L-118, wyd. 1 z 09.02.2026 r.","na podstawie metody Hach nr 8326"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie glinu\nZakres (0,020 – 0,25) mg/l\nMetoda spektrofotometryczna PB/L-118, wyd. 1 z 09.02.2026 r. | na podstawie metody Hach nr 8326 Woda, Woda do spozycia przez ludzi Stezenie glinu\nZakres (0,020 – 0,25) mg/l\nMetoda spektrofotometryczna PB/L-118, wyd. 1 z 09.02.2026 r. | na podstawie metody Hach nr 8326","categories":["water"],"row_index":75,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa0112","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Indeks nadmanganianowy","parameters":[{"name":"Zakres","range":"(1,0 – 20) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Indeks nadmanganianowy\nZakres (1,0 – 20) mg/l O2\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Indeks nadmanganianowy\nZakres (1,0 – 20) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda, Woda do spozycia przez ludzi Indeks nadmanganianowy\nZakres (1,0 – 20) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":76,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa0113","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie fluorków","parameters":[{"name":"Zakres","range":"(0,10 – 2,0) mg/l"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"Stężenie fluorków\nZakres (0,10 – 2,0) mg/l\nMetoda potencjometryczna","reference":"PN-78/C-04588/03","norm_bases":["PN-78/C-04588/03"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie fluorków\nZakres (0,10 – 2,0) mg/l\nMetoda potencjometryczna PN-78/C-04588/03 Woda, Woda do spozycia przez ludzi Stezenie fluorkow\nZakres (0,10 – 2,0) mg/l\nMetoda potencjometryczna PN-78/C-04588/03","categories":["water"],"row_index":77,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa0114","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Chlor całkowity","parameters":[{"name":"Zakres","range":"(0,050 – 4,0) mg/l"},{"name":"Chlor związany (z obliczeń)"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chlor całkowity\nZakres:\nZakres (0,050 – 4,0) mg/l\nChlor związany (z obliczeń)\nMetoda spektrofotometryczna","reference":"PB/L-119 wyd. 1 z 09.02.2026 | na podstawie metody Hach nr 8167","norm_bases":["PB/L-119 wyd. 1 z 09.02.2026","na podstawie metody Hach nr 8167"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Chlor całkowity\nZakres:\nZakres (0,050 – 4,0) mg/l\nChlor związany (z obliczeń)\nMetoda spektrofotometryczna PB/L-119 wyd. 1 z 09.02.2026 | na podstawie metody Hach nr 8167 Woda, Woda do spozycia przez ludzi Chlor calkowity\nZakres:\nZakres (0,050 – 4,0) mg/l\nChlor zwiazany (z obliczen)\nMetoda spektrofotometryczna PB/L-119 wyd. 1 z 09.02.2026 | na podstawie metody Hach nr 8167","categories":["water"],"row_index":78,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa0115","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)","parameters":[{"name":"Zakres","range":"(5 – 700) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (5 – 700) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (5 – 700) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999 Woda, Woda do spozycia przez ludzi Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna)\nZakres (5 – 700) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":79,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa0116","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie wapnia","parameters":[{"name":"Zakres","range":"(2 – 100) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie wapnia\nZakres (2 – 100) mg/l\nMetoda miareczkowa","reference":"PN-ISO 6058:1999","norm_bases":["PN-ISO 6058:1999"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie wapnia\nZakres (2 – 100) mg/l\nMetoda miareczkowa PN-ISO 6058:1999 Woda, Woda do spozycia przez ludzi Stezenie wapnia\nZakres (2 – 100) mg/l\nMetoda miareczkowa PN-ISO 6058:1999","categories":["water"],"row_index":80,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa0117","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie magnezu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie magnezu (z obliczeń)","reference":"PN-99/C-04554/04 załącznik A","norm_bases":["PN-99/C-04554/04 załącznik A"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie magnezu (z obliczeń) PN-99/C-04554/04 załącznik A Woda, Woda do spozycia przez ludzi Stezenie magnezu (z obliczen) PN-99/C-04554/04 zalacznik A","categories":["water"],"row_index":81,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa0118","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Woda na pływalniach","methodology":"Pobieranie próbek do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.5, 4.4.6","norm_bases":["PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.5, 4.4.6"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Woda na pływalniach Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.5, 4.4.6 Woda, Woda do spozycia przez ludzi, Woda na plywalniach Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007 z wylaczeniem pkt. 4.4.5, 4.4.6","categories":["water","microbiology"],"row_index":82,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa0119","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w 22°C","parameters":[],"technique":"Metoda płytkowa – posiew wgłębny","techniques":["Metoda płytkowa – posiew wgłębny"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w 22°C\nMetoda płytkowa – posiew wgłębny","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 22°C\nMetoda płytkowa – posiew wgłębny PN-EN ISO 6222:2004 Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 22°C\nMetoda plytkowa – posiew wglebny PN-EN ISO 6222:2004","categories":["water"],"row_index":83,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa011a","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w 36°C","parameters":[],"technique":"Metoda płytkowa – posiew wgłębny","techniques":["Metoda płytkowa – posiew wgłębny"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w 36°C\nMetoda płytkowa – posiew wgłębny","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 36°C\nMetoda płytkowa – posiew wgłębny PN-EN ISO 6222:2004 Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 36°C\nMetoda plytkowa – posiew wglebny PN-EN ISO 6222:2004","categories":["water"],"row_index":84,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa011b","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba enterokoków kałowych","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba enterokoków kałowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba enterokoków kałowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda do spozycia przez ludzi Liczba enterokokow kalowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":85,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa011c","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba bakterii Legionella sp. Matryca A Procedura 5, podłoże A (BCYE), Procedura 7, podłoże C (GVPC)","parameters":[{"name":"Zakres","range":"od 1 jtk/100 ml;"},{"name":"od 1 jtk / 1000 ml"}],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii Legionella sp. Matryca A Procedura 5, podłoże A (BCYE), Procedura 7, podłoże C (GVPC)\nZakres:\nZakres od 1 jtk/100 ml;\nod 1 jtk / 1000 ml\nMetoda filtracji membranowej","reference":"PN-EN ISO 11731:2017-08 +Ap1:2019-12","norm_bases":["PN-EN ISO 11731:2017-08 +Ap1:2019-12"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba bakterii Legionella sp. Matryca A Procedura 5, podłoże A (BCYE), Procedura 7, podłoże C (GVPC)\nZakres:\nZakres od 1 jtk/100 ml;\nod 1 jtk / 1000 ml\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 +Ap1:2019-12 Woda do spozycia przez ludzi Liczba bakterii Legionella sp. Matryca A Procedura 5, podloze A (BCYE), Procedura 7, podloze C (GVPC)\nZakres:\nZakres od 1 jtk/100 ml;\nod 1 jtk / 1000 ml\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 +Ap1:2019-12","categories":["microbiology","water"],"row_index":86,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa011d","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda do spozycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":87,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa011e","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba bakterii grupy coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda do spozycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":88,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa011f","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba Pseudomonas aeruginosa","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009 Woda do spozycia przez ludzi Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water"],"row_index":89,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa0120","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Ogólna liczba mikroorganizmów w 36°C","parameters":[],"technique":"Metoda płytkowa – posiew wgłębny","techniques":["Metoda płytkowa – posiew wgłębny"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w 36°C\nMetoda płytkowa – posiew wgłębny","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Ogólna liczba mikroorganizmów w 36°C\nMetoda płytkowa – posiew wgłębny PN-EN ISO 6222:2004 Woda na plywalniach Ogolna liczba mikroorganizmow w 36°C\nMetoda plytkowa – posiew wglebny PN-EN ISO 6222:2004","categories":["water"],"row_index":90,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa0121","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Liczba Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda na plywalniach Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":91,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa0122","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Liczba gronkowców koagulazododatnich","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba gronkowców koagulazododatnich\nMetoda filtracji membranowej","reference":"PB/L-114, wyd. 1 z 09.02.2026 r.","norm_bases":["PB/L-114, wyd. 1 z 09.02.2026 r."],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Liczba gronkowców koagulazododatnich\nMetoda filtracji membranowej PB/L-114, wyd. 1 z 09.02.2026 r. Woda na plywalniach Liczba gronkowcow koagulazododatnich\nMetoda filtracji membranowej PB/L-114, wyd. 1 z 09.02.2026 r.","categories":["water"],"row_index":92,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa0123","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Liczba bakterii Legionella sp. Matryca A Procedura 5, podłoże A (BCYE), Procedura 7, podłoże C (GVPC)","parameters":[{"name":"Zakres","range":"od 1 jtk/100 ml;"}],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii Legionella sp. Matryca A Procedura 5, podłoże A (BCYE), Procedura 7, podłoże C (GVPC)\nZakres od 1 jtk/100 ml;\nMetoda filtracji membranowej","reference":"PN-EN ISO 11731:2017-08 +Ap1:2019-12","norm_bases":["PN-EN ISO 11731:2017-08 +Ap1:2019-12"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Liczba bakterii Legionella sp. Matryca A Procedura 5, podłoże A (BCYE), Procedura 7, podłoże C (GVPC)\nZakres od 1 jtk/100 ml;\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 +Ap1:2019-12 Woda na plywalniach Liczba bakterii Legionella sp. Matryca A Procedura 5, podloze A (BCYE), Procedura 7, podloze C (GVPC)\nZakres od 1 jtk/100 ml;\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 +Ap1:2019-12","categories":["microbiology","water"],"row_index":93,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa0124","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Liczba Pseudomonas aeruginosa","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009 Woda na plywalniach Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water"],"row_index":94,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa0125","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda","methodology":"Ogólna liczba mikroorganizmów w 22°C","parameters":[],"technique":"Metoda płytkowa – posiew wgłębny","techniques":["Metoda płytkowa – posiew wgłębny"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w 22°C\nMetoda płytkowa – posiew wgłębny","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Ogólna liczba mikroorganizmów w 22°C\nMetoda płytkowa – posiew wgłębny PN-EN ISO 6222:2004 Woda Ogolna liczba mikroorganizmow w 22°C\nMetoda plytkowa – posiew wglebny PN-EN ISO 6222:2004","categories":["water"],"row_index":95,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa0126","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda","methodology":"Ogólna liczba mikroorganizmów w 36°C","parameters":[],"technique":"Metoda płytkowa – posiew wgłębny","techniques":["Metoda płytkowa – posiew wgłębny"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w 36°C\nMetoda płytkowa – posiew wgłębny","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Ogólna liczba mikroorganizmów w 36°C\nMetoda płytkowa – posiew wgłębny PN-EN ISO 6222:2004 Woda Ogolna liczba mikroorganizmow w 36°C\nMetoda plytkowa – posiew wglebny PN-EN ISO 6222:2004","categories":["water"],"row_index":96,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa0127","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda","methodology":"Liczba enterokoków kałowych","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba enterokoków kałowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Liczba enterokoków kałowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda Liczba enterokokow kalowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":97,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa0128","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda","methodology":"Liczba Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":98,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa0129","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda","methodology":"Liczba bakterii grupy coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":99,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa012a","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie manganu","parameters":[{"name":"Zakres","range":"(15 - 700) μg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie manganu\nZakres (15 - 700) μg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 8288:2002 Metoda A","norm_bases":["PN-ISO 8288:2002 Metoda A"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie manganu\nZakres (15 - 700) μg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 Metoda A Woda, Woda do spozycia przez ludzi Stezenie manganu\nZakres (15 - 700) μg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 Metoda A","categories":["water"],"row_index":100,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa012b","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie żelaza","parameters":[{"name":"Zakres","range":"(50 - 5000) μg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie żelaza\nZakres (50 - 5000) μg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 8288:2002 Metoda A","norm_bases":["PN-ISO 8288:2002 Metoda A"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie żelaza\nZakres (50 - 5000) μg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 Metoda A Woda, Woda do spozycia przez ludzi Stezenie zelaza\nZakres (50 - 5000) μg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 Metoda A","categories":["water"],"row_index":101,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa012c","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie trichlorometanu (chloroform)","parameters":[{"name":"Zakres","range":"(5,0 - 50) μg/l"},{"name":"Stężenie dibromochlorometanu"},{"name":"Zakres","range":"(3,0 - 50) μg/l"},{"name":"Stężenie bromodichlorometanu"},{"name":"Zakres","range":"(5,0 - 50) μg/l"},{"name":"Stężenie tribromometanu (bromoform)"},{"name":"Zakres","range":"(5,0 - 50) μg/l"},{"name":"Σ THM (Σ trichlorometanu, dibromochlorometanu, bromodichlorometanu, tribromometanu) (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","techniques":["Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)"],"computed":[],"activity":"Stężenie trichlorometanu (chloroform)\nZakres:\nZakres (5,0 - 50) μg/l\nStężenie dibromochlorometanu\nZakres (3,0 - 50) μg/l\nStężenie bromodichlorometanu\nZakres (5,0 - 50) μg/l\nStężenie tribromometanu (bromoform)\nZakres (5,0 - 50) μg/l\nΣ THM (Σ trichlorometanu, dibromochlorometanu, bromodichlorometanu, tribromometanu) (z obliczeń)\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","reference":"PN-EN ISO 10301:2002","norm_bases":["PN-EN ISO 10301:2002"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie trichlorometanu (chloroform)\nZakres:\nZakres (5,0 - 50) μg/l\nStężenie dibromochlorometanu\nZakres (3,0 - 50) μg/l\nStężenie bromodichlorometanu\nZakres (5,0 - 50) μg/l\nStężenie tribromometanu (bromoform)\nZakres (5,0 - 50) μg/l\nΣ THM (Σ trichlorometanu, dibromochlorometanu, bromodichlorometanu, tribromometanu) (z obliczeń)\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) PN-EN ISO 10301:2002 Woda, Woda do spozycia przez ludzi Stezenie trichlorometanu (chloroform)\nZakres:\nZakres (5,0 - 50) μg/l\nStezenie dibromochlorometanu\nZakres (3,0 - 50) μg/l\nStezenie bromodichlorometanu\nZakres (5,0 - 50) μg/l\nStezenie tribromometanu (bromoform)\nZakres (5,0 - 50) μg/l\nΣ THM (Σ trichlorometanu, dibromochlorometanu, bromodichlorometanu, tribromometanu) (z obliczen)\nMetoda chromatografii gazowej z detekcja wychwytu elektronow (GC-ECD) PN-EN ISO 10301:2002","categories":["water"],"row_index":102,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa012d","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością","methodology":"Migracja globalna do wodnych płynów modelowych","parameters":[{"name":"metoda przez całkowite zanurzenie woda","range":"(1,0 -150) mg/dm2"},{"name":"Zakres","range":"3% kw. octowy (1,0 - 150) mg/dm2"},{"name":"10% etanol","range":"(1,0 - 150) mg/dm2"},{"name":"20% etanol","range":"(1,0 - 150) mg/dm2"},{"name":"50% etanol","range":"(1,0 - 150) mg/dm2"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Migracja globalna do wodnych płynów modelowych\nZakres:\nmetoda przez całkowite zanurzenie woda (1,0 -150) mg/dm2\nZakres 3% kw. octowy (1,0 - 150) mg/dm2\n10% etanol (1,0 - 150) mg/dm2\n20% etanol (1,0 - 150) mg/dm2\n50% etanol (1,0 - 150) mg/dm2\nMetoda wagowa","reference":"PN-EN 1186-3:2023-01","norm_bases":["PN-EN 1186-3:2023-01"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością Migracja globalna do wodnych płynów modelowych\nZakres:\nmetoda przez całkowite zanurzenie woda (1,0 -150) mg/dm2\nZakres 3% kw. octowy (1,0 - 150) mg/dm2\n10% etanol (1,0 - 150) mg/dm2\n20% etanol (1,0 - 150) mg/dm2\n50% etanol (1,0 - 150) mg/dm2\nMetoda wagowa PN-EN 1186-3:2023-01 Materialy i wyroby z tworzyw sztucznych przeznaczone do kontaktu z zywnoscia Migracja globalna do wodnych plynow modelowych\nZakres:\nmetoda przez calkowite zanurzenie woda (1,0 -150) mg/dm2\nZakres 3% kw. octowy (1,0 - 150) mg/dm2\n10% etanol (1,0 - 150) mg/dm2\n20% etanol (1,0 - 150) mg/dm2\n50% etanol (1,0 - 150) mg/dm2\nMetoda wagowa PN-EN 1186-3:2023-01","categories":["materials","food"],"row_index":103,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa012e","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością","methodology":"Migracja globalna do wodnych płynów modelowych","parameters":[{"name":"metoda z zastosowaniem komory pomiarowej woda","range":"(1,0 -150) mg/dm2"},{"name":"Zakres","range":"3% kw. octowy (1,0 - 150) mg/dm2"},{"name":"10% etanol","range":"(1,0 - 150) mg/dm2"},{"name":"20% etanol","range":"(1,0 - 150) mg/dm2"},{"name":"50% etanol","range":"(1,0 - 150) mg/dm2"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Migracja globalna do wodnych płynów modelowych\nZakres:\nmetoda z zastosowaniem komory pomiarowej woda (1,0 -150) mg/dm2\nZakres 3% kw. octowy (1,0 - 150) mg/dm2\n10% etanol (1,0 - 150) mg/dm2\n20% etanol (1,0 - 150) mg/dm2\n50% etanol (1,0 - 150) mg/dm2\nMetoda wagowa","reference":"PN-EN 1186-3:2023-01","norm_bases":["PN-EN 1186-3:2023-01"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością Migracja globalna do wodnych płynów modelowych\nZakres:\nmetoda z zastosowaniem komory pomiarowej woda (1,0 -150) mg/dm2\nZakres 3% kw. octowy (1,0 - 150) mg/dm2\n10% etanol (1,0 - 150) mg/dm2\n20% etanol (1,0 - 150) mg/dm2\n50% etanol (1,0 - 150) mg/dm2\nMetoda wagowa PN-EN 1186-3:2023-01 Materialy i wyroby z tworzyw sztucznych przeznaczone do kontaktu z zywnoscia Migracja globalna do wodnych plynow modelowych\nZakres:\nmetoda z zastosowaniem komory pomiarowej woda (1,0 -150) mg/dm2\nZakres 3% kw. octowy (1,0 - 150) mg/dm2\n10% etanol (1,0 - 150) mg/dm2\n20% etanol (1,0 - 150) mg/dm2\n50% etanol (1,0 - 150) mg/dm2\nMetoda wagowa PN-EN 1186-3:2023-01","categories":["materials","food"],"row_index":104,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa012f","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością","methodology":"Migracja globalna do wodnych płynów modelowych","parameters":[{"name":"metoda z zastosowaniem torebki woda","range":"(1,0 - 150) mg/dm2"},{"name":"Zakres","range":"3% kw. octowy (1,0 - 150) mg/dm2"},{"name":"10% etanol","range":"(1,0 - 150) mg/dm2"},{"name":"20% etanol","range":"(1,0 - 150) mg/dm2"},{"name":"50% etanol","range":"(1,0 - 150) mg/dm2"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Migracja globalna do wodnych płynów modelowych\nZakres:\nmetoda z zastosowaniem torebki woda (1,0 - 150) mg/dm2\nZakres 3% kw. octowy (1,0 - 150) mg/dm2\n10% etanol (1,0 - 150) mg/dm2\n20% etanol (1,0 - 150) mg/dm2\n50% etanol (1,0 - 150) mg/dm2\nMetoda wagowa","reference":"PN-EN 1186-3:2023-01","norm_bases":["PN-EN 1186-3:2023-01"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością Migracja globalna do wodnych płynów modelowych\nZakres:\nmetoda z zastosowaniem torebki woda (1,0 - 150) mg/dm2\nZakres 3% kw. octowy (1,0 - 150) mg/dm2\n10% etanol (1,0 - 150) mg/dm2\n20% etanol (1,0 - 150) mg/dm2\n50% etanol (1,0 - 150) mg/dm2\nMetoda wagowa PN-EN 1186-3:2023-01 Materialy i wyroby z tworzyw sztucznych przeznaczone do kontaktu z zywnoscia Migracja globalna do wodnych plynow modelowych\nZakres:\nmetoda z zastosowaniem torebki woda (1,0 - 150) mg/dm2\nZakres 3% kw. octowy (1,0 - 150) mg/dm2\n10% etanol (1,0 - 150) mg/dm2\n20% etanol (1,0 - 150) mg/dm2\n50% etanol (1,0 - 150) mg/dm2\nMetoda wagowa PN-EN 1186-3:2023-01","categories":["materials","food"],"row_index":105,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa0130","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością","methodology":"Migracja globalna do wodnych płynów modelowych","parameters":[{"name":"metoda przez napełnienie wyrobu woda","range":"(1,0 - 150) mg/dm2"},{"name":"Zakres","range":"(6,0 - 500) mg/kg"},{"name":"3% kw. octowy","range":"(1,0 - 150) mg/dm2"},{"name":"(6,0 - 500) mg/kg"},{"name":"10% etanol","range":"(1,0 - 150) mg/dm2"},{"name":"(6,0 - 500) mg/kg"},{"name":"20% etanol","range":"(1,0 - 150) mg/dm2"},{"name":"(6,0 - 500) mg/kg"},{"name":"50% etanol","range":"(1,0 - 150) mg/dm2"},{"name":"(6,0 - 500) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Migracja globalna do wodnych płynów modelowych\nZakres:\nmetoda przez napełnienie wyrobu woda (1,0 - 150) mg/dm2\nZakres (6,0 - 500) mg/kg\n3% kw. octowy (1,0 - 150) mg/dm2\n(6,0 - 500) mg/kg\n10% etanol (1,0 - 150) mg/dm2\n(6,0 - 500) mg/kg\n20% etanol (1,0 - 150) mg/dm2\n(6,0 - 500) mg/kg\n50% etanol (1,0 - 150) mg/dm2\n(6,0 - 500) mg/kg\nMetoda wagowa","reference":"PN-EN 1186-3:2023-01","norm_bases":["PN-EN 1186-3:2023-01"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością Migracja globalna do wodnych płynów modelowych\nZakres:\nmetoda przez napełnienie wyrobu woda (1,0 - 150) mg/dm2\nZakres (6,0 - 500) mg/kg\n3% kw. octowy (1,0 - 150) mg/dm2\n(6,0 - 500) mg/kg\n10% etanol (1,0 - 150) mg/dm2\n(6,0 - 500) mg/kg\n20% etanol (1,0 - 150) mg/dm2\n(6,0 - 500) mg/kg\n50% etanol (1,0 - 150) mg/dm2\n(6,0 - 500) mg/kg\nMetoda wagowa PN-EN 1186-3:2023-01 Materialy i wyroby z tworzyw sztucznych przeznaczone do kontaktu z zywnoscia Migracja globalna do wodnych plynow modelowych\nZakres:\nmetoda przez napelnienie wyrobu woda (1,0 - 150) mg/dm2\nZakres (6,0 - 500) mg/kg\n3% kw. octowy (1,0 - 150) mg/dm2\n(6,0 - 500) mg/kg\n10% etanol (1,0 - 150) mg/dm2\n(6,0 - 500) mg/kg\n20% etanol (1,0 - 150) mg/dm2\n(6,0 - 500) mg/kg\n50% etanol (1,0 - 150) mg/dm2\n(6,0 - 500) mg/kg\nMetoda wagowa PN-EN 1186-3:2023-01","categories":["materials","food"],"row_index":106,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa0131","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością","methodology":"Migracja globalna do mediów substytucyjnych","parameters":[{"name":"izooktan","range":"(1,0 - 150,0) mg/dm2"},{"name":"Zakres","range":"(6,0 - 500,0) mg/kg"},{"name":"95% etanol","range":"(1,0 - 150,0) mg/dm2"},{"name":"(6,0 - 500,0) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Migracja globalna do mediów substytucyjnych\nZakres:\nizooktan (1,0 - 150,0) mg/dm2\nZakres (6,0 - 500,0) mg/kg\n95% etanol (1,0 - 150,0) mg/dm2\n(6,0 - 500,0) mg/kg\nMetoda wagowa","reference":"PN-EN 1186-3:2023-01","norm_bases":["PN-EN 1186-3:2023-01"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością Migracja globalna do mediów substytucyjnych\nZakres:\nizooktan (1,0 - 150,0) mg/dm2\nZakres (6,0 - 500,0) mg/kg\n95% etanol (1,0 - 150,0) mg/dm2\n(6,0 - 500,0) mg/kg\nMetoda wagowa PN-EN 1186-3:2023-01 Materialy i wyroby z tworzyw sztucznych przeznaczone do kontaktu z zywnoscia Migracja globalna do mediow substytucyjnych\nZakres:\nizooktan (1,0 - 150,0) mg/dm2\nZakres (6,0 - 500,0) mg/kg\n95% etanol (1,0 - 150,0) mg/dm2\n(6,0 - 500,0) mg/kg\nMetoda wagowa PN-EN 1186-3:2023-01","categories":["materials","food"],"row_index":107,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa0132","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością","methodology":"Migracja formaldehydu do płynów modelowych","parameters":[{"name":"Zakres","range":"3% kw. octowy (1,5 - 30,0) mg/kg"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Migracja formaldehydu do płynów modelowych\nZakres 3% kw. octowy (1,5 - 30,0) mg/kg\nMetoda spektrofotometryczna","reference":"CEN/TS 13130-23: 2005","norm_bases":["CEN/TS 13130-23: 2005"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością Migracja formaldehydu do płynów modelowych\nZakres 3% kw. octowy (1,5 - 30,0) mg/kg\nMetoda spektrofotometryczna CEN/TS 13130-23: 2005 Materialy i wyroby z tworzyw sztucznych przeznaczone do kontaktu z zywnoscia Migracja formaldehydu do plynow modelowych\nZakres 3% kw. octowy (1,5 - 30,0) mg/kg\nMetoda spektrofotometryczna CEN/TS 13130-23: 2005","categories":["materials","food"],"row_index":108,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa0133","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością","methodology":"Migracja pierwszorzędowych amin aromatycznych (PAA) do płynów modelowych – 3% kw. octowy","parameters":[{"name":"Zakres","range":"2,4-TDA (0,002 - 0,03) mg/kg"},{"name":"2,6-TDA","range":"(0,002 - 0,03) mg/kg"},{"name":"Anilina","range":"(0,002 - 0,03) mg/kg"},{"name":"4,4-MDA","range":"(0,002 - 0,03) mg/kg"},{"name":"1,3 - fenylenodiamina","range":"(0,002 – 0,03) mg/kg"},{"name":"1,5 - diaminonaftalen","range":"(0,002 – 0,03) mg/kg"},{"name":"4,4 - oksydianilina","range":"(0,002 – 0,03) mg/kg"},{"name":"3,3 - dimetylobenzydyna","range":"(0,002 – 0,03) mg/kg"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC – DAD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC – DAD)"],"computed":[],"activity":"Migracja pierwszorzędowych amin aromatycznych (PAA) do płynów modelowych – 3% kw. octowy\nZakres:\nZakres 2,4-TDA (0,002 - 0,03) mg/kg\n2,6-TDA (0,002 - 0,03) mg/kg\nAnilina (0,002 - 0,03) mg/kg\n4,4-MDA (0,002 - 0,03) mg/kg\n1,3 - fenylenodiamina (0,002 – 0,03) mg/kg\n1,5 - diaminonaftalen (0,002 – 0,03) mg/kg\n4,4 - oksydianilina (0,002 – 0,03) mg/kg\n3,3 - dimetylobenzydyna (0,002 – 0,03) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC – DAD)","reference":"PB/L-84 wyd. 3 z dnia 10.01.2024 r.","norm_bases":["PB/L-84 wyd. 3 z dnia 10.01.2024 r."],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością Migracja pierwszorzędowych amin aromatycznych (PAA) do płynów modelowych – 3% kw. octowy\nZakres:\nZakres 2,4-TDA (0,002 - 0,03) mg/kg\n2,6-TDA (0,002 - 0,03) mg/kg\nAnilina (0,002 - 0,03) mg/kg\n4,4-MDA (0,002 - 0,03) mg/kg\n1,3 - fenylenodiamina (0,002 – 0,03) mg/kg\n1,5 - diaminonaftalen (0,002 – 0,03) mg/kg\n4,4 - oksydianilina (0,002 – 0,03) mg/kg\n3,3 - dimetylobenzydyna (0,002 – 0,03) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC – DAD) PB/L-84 wyd. 3 z dnia 10.01.2024 r. Materialy i wyroby z tworzyw sztucznych przeznaczone do kontaktu z zywnoscia Migracja pierwszorzedowych amin aromatycznych (PAA) do plynow modelowych – 3% kw. octowy\nZakres:\nZakres 2,4-TDA (0,002 - 0,03) mg/kg\n2,6-TDA (0,002 - 0,03) mg/kg\nAnilina (0,002 - 0,03) mg/kg\n4,4-MDA (0,002 - 0,03) mg/kg\n1,3 - fenylenodiamina (0,002 – 0,03) mg/kg\n1,5 - diaminonaftalen (0,002 – 0,03) mg/kg\n4,4 - oksydianilina (0,002 – 0,03) mg/kg\n3,3 - dimetylobenzydyna (0,002 – 0,03) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcja matryca diodowa (HPLC – DAD) PB/L-84 wyd. 3 z dnia 10.01.2024 r.","categories":["materials","food"],"row_index":109,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa0134","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością","methodology":"Migracja bisfenolu A","parameters":[{"name":"Zakres","range":"(0,01 - 0,1) mg/kg"}],"technique":"Metoda chromatografii cieczowej z detekcją fluorescencyjną (HPLC – FLD)","techniques":["Metoda chromatografii cieczowej z detekcją fluorescencyjną (HPLC – FLD)"],"computed":[],"activity":"Migracja bisfenolu A\nZakres (0,01 - 0,1) mg/kg\nMetoda chromatografii cieczowej z detekcją fluorescencyjną (HPLC – FLD)","reference":"PB/L-108 wyd. 1 z dnia 05.09.2022r.","norm_bases":["PB/L-108 wyd. 1 z dnia 05.09.2022r."],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością Migracja bisfenolu A\nZakres (0,01 - 0,1) mg/kg\nMetoda chromatografii cieczowej z detekcją fluorescencyjną (HPLC – FLD) PB/L-108 wyd. 1 z dnia 05.09.2022r. Materialy i wyroby z tworzyw sztucznych przeznaczone do kontaktu z zywnoscia Migracja bisfenolu A\nZakres (0,01 - 0,1) mg/kg\nMetoda chromatografii cieczowej z detekcja fluorescencyjna (HPLC – FLD) PB/L-108 wyd. 1 z dnia 05.09.2022r.","categories":["materials","food"],"row_index":110,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa0135","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Papier i tektura przeznaczone do kontaktu z żywnością","methodology":"Zawartość formaldehydu w wyciągu wodnym","parameters":[{"name":"Zakres","range":"(1 – 25) mg/kg"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość formaldehydu w wyciągu wodnym\nZakres (1 – 25) mg/kg\nMetoda spektrofotometryczna","reference":"PN-EN 1541:2003","norm_bases":["PN-EN 1541:2003"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Papier i tektura przeznaczone do kontaktu z żywnością Zawartość formaldehydu w wyciągu wodnym\nZakres (1 – 25) mg/kg\nMetoda spektrofotometryczna PN-EN 1541:2003 Papier i tektura przeznaczone do kontaktu z zywnoscia Zawartosc formaldehydu w wyciagu wodnym\nZakres (1 – 25) mg/kg\nMetoda spektrofotometryczna PN-EN 1541:2003","categories":["food"],"row_index":111,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa0136","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Papier i tektura przeznaczone do kontaktu z żywnością","methodology":"Zawartość niezwiązanego fenolu w wyciągu wodnym","parameters":[{"name":"Zakres","range":"(0,25 – 25) mg/kg"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość niezwiązanego fenolu w wyciągu wodnym\nZakres (0,25 – 25) mg/kg\nMetoda spektrofotometryczna","reference":"PN-P-50430:1998 załącznik D","norm_bases":["PN-P-50430:1998 załącznik D"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Papier i tektura przeznaczone do kontaktu z żywnością Zawartość niezwiązanego fenolu w wyciągu wodnym\nZakres (0,25 – 25) mg/kg\nMetoda spektrofotometryczna PN-P-50430:1998 załącznik D Papier i tektura przeznaczone do kontaktu z zywnoscia Zawartosc niezwiazanego fenolu w wyciagu wodnym\nZakres (0,25 – 25) mg/kg\nMetoda spektrofotometryczna PN-P-50430:1998 zalacznik D","categories":["food"],"row_index":112,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa0137","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Produkty kosmetyczne","methodology":"Zawartość formaldehydu","parameters":[{"name":"Zakres","range":"(0,002 - 0,05) %"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość formaldehydu\nZakres (0,002 - 0,05) %\nMetoda spektrofotometryczna","reference":"Rozporządzenie Ministra Zdrowia z dnia 19 marca 2020 r. (Dz. U. z dnia 26 maja 2020r., poz. 931) Zał. punkt XI","norm_bases":["Rozporządzenie Ministra Zdrowia z dnia 19 marca 2020 r. (Dz. U. z dnia 26 maja 2020r., poz. 931) Zał. punkt XI"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Produkty kosmetyczne Zawartość formaldehydu\nZakres (0,002 - 0,05) %\nMetoda spektrofotometryczna Rozporządzenie Ministra Zdrowia z dnia 19 marca 2020 r. (Dz. U. z dnia 26 maja 2020r., poz. 931) Zał. punkt XI Produkty kosmetyczne Zawartosc formaldehydu\nZakres (0,002 - 0,05) %\nMetoda spektrofotometryczna Rozporzadzenie Ministra Zdrowia z dnia 19 marca 2020 r. (Dz. U. z dnia 26 maja 2020r., poz. 931) Zal. punkt XI","categories":["other"],"row_index":113,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa0138","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Produkty kosmetyczne","methodology":"Zawartość azotynów","parameters":[{"name":"Zakres","range":"(0,04 - 0,20)%"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość azotynów\nZakres (0,04 - 0,20)%\nMetoda spektrofotometryczna","reference":"Rozporządzenie Ministra Zdrowia z dnia 19 marca 2020 r. (Dz. U. z dnia 26 maja 2020r., poz. 931) Zał. punkt X","norm_bases":["Rozporządzenie Ministra Zdrowia z dnia 19 marca 2020 r. (Dz. U. z dnia 26 maja 2020r., poz. 931) Zał. punkt X"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Produkty kosmetyczne Zawartość azotynów\nZakres (0,04 - 0,20)%\nMetoda spektrofotometryczna Rozporządzenie Ministra Zdrowia z dnia 19 marca 2020 r. (Dz. U. z dnia 26 maja 2020r., poz. 931) Zał. punkt X Produkty kosmetyczne Zawartosc azotynow\nZakres (0,04 - 0,20)%\nMetoda spektrofotometryczna Rozporzadzenie Ministra Zdrowia z dnia 19 marca 2020 r. (Dz. U. z dnia 26 maja 2020r., poz. 931) Zal. punkt X","categories":["other"],"row_index":114,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa0139","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Środowisko pracy - hałas","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(44 – 136) dB"},{"name":"Szczytowy poziom dźwięku C"},{"name":"Zakres","range":"(50 – 140) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (44 – 136) dB\nSzczytowy poziom dźwięku C\nZakres (50 – 140) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 | PN-EN ISO 9612: 2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612: 2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań i Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (44 – 136) dB\nSzczytowy poziom dźwięku C\nZakres (50 – 140) dB\nMetoda pomiarowa bezpośrednia PN-N-01307:1994 | PN-EN ISO 9612: 2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11 Srodowisko pracy - halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A\nZakres:\nZakres (44 – 136) dB\nSzczytowy poziom dzwieku C\nZakres (50 – 140) dB\nMetoda pomiarowa bezposrednia PN-N-01307:1994 | PN-EN ISO 9612: 2011 z wylaczeniem metody obejmujacej strategie 2 i 3 – punkt 10 i 11","categories":["environment"],"row_index":115,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa013a","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Środowisko pracy - hałas","methodology":"Poziom ekspozycji na hałas odniesiony do:","parameters":[{"name":"8-godzinnego dobowego wymiaru czasu pracy"},{"name":"tygodnia pracy (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godzinnego dobowego wymiaru czasu pracy\ntygodnia pracy (z obliczeń)","reference":"PN-N-01307:1994 | PN-EN ISO 9612: 2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612: 2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań i Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - hałas Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godzinnego dobowego wymiaru czasu pracy\ntygodnia pracy (z obliczeń) PN-N-01307:1994 | PN-EN ISO 9612: 2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11 Srodowisko pracy - halas Poziom ekspozycji na halas odniesiony do:\nZakres:\n8-godzinnego dobowego wymiaru czasu pracy\ntygodnia pracy (z obliczen) PN-N-01307:1994 | PN-EN ISO 9612: 2011 z wylaczeniem metody obejmujacej strategie 2 i 3 – punkt 10 i 11","categories":["environment"],"row_index":116,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa013b","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Środowisko pracy - drgania działające na organizm człowieka przez kończyny górne","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","parameters":[{"name":"Zakres","range":"(0,06 – 200) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,06 – 200) m/s2\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-2:2004/A1:2015-11"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań i Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - drgania działające na organizm człowieka przez kończyny górne Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,06 – 200) m/s2\nMetoda pomiarowa bezpośrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 Srodowisko pracy - drgania dzialajace na organizm czlowieka przez konczyny gorne Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres (0,06 – 200) m/s2\nMetoda pomiarowa bezposrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","categories":["environment"],"row_index":117,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa013c","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Środowisko pracy - drgania działające na organizm człowieka przez kończyny górne","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-2:2004/A1:2015-11"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań i Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - drgania działające na organizm człowieka przez kończyny górne Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 Srodowisko pracy - drgania dzialajace na organizm czlowieka przez konczyny gorne Ekspozycja dzienna, wyrazona w postaci rownowaznej energetycznie dla 8-godzin dzialania sumy wektorowej skutecznych, skorygowanych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci sumy wektorowej skutecznych, wazonych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz) (z obliczen) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","categories":["environment"],"row_index":118,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa013d","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","parameters":[{"name":"Zakres","range":"(0,01– 157) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,01– 157) m/s2\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań i Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,01– 157) m/s2\nMetoda pomiarowa bezpośrednia PN-EN 14253+A1:2011 Srodowisko pracy – drgania o ogolnym dzialaniu na organizm czlowieka Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres (0,01– 157) m/s2\nMetoda pomiarowa bezposrednia PN-EN 14253+A1:2011","categories":["environment"],"row_index":119,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa013e","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz) (z obliczeń)","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań i Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz) (z obliczeń) PN-EN 14253+A1:2011 Srodowisko pracy – drgania o ogolnym dzialaniu na organizm czlowieka Ekspozycja dzienna, wyrazona w postaci rownowaznego energetycznie dla 8-godzin dzialania skutecznego, skorygowanego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1,4awx, 1,4awy, awz), Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci skutecznego, wazonego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1,4awx, 1,4awy, awz) (z obliczen) PN-EN 14253+A1:2011","categories":["environment"],"row_index":120,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa013f","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie elektryczne","methodology":"Natężenie oświetlenia","parameters":[{"name":"Zakres","range":"(5 – 10 000) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie oświetlenia\nZakres (5 – 10 000) lx\nMetoda pomiarowa bezpośrednia","reference":"PN-83/E-04040.03","norm_bases":["PN-83/E-04040.03"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań i Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie elektryczne Natężenie oświetlenia\nZakres (5 – 10 000) lx\nMetoda pomiarowa bezpośrednia PN-83/E-04040.03 Srodowisko pracy - oswietlenie elektryczne Natezenie oswietlenia\nZakres (5 – 10 000) lx\nMetoda pomiarowa bezposrednia PN-83/E-04040.03","categories":["environment"],"row_index":121,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa0140","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie elektryczne","methodology":"Równomierność oświetlenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równomierność oświetlenia (z obliczeń)","reference":"PN-83/E-04040.03","norm_bases":["PN-83/E-04040.03"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań i Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie elektryczne Równomierność oświetlenia (z obliczeń) PN-83/E-04040.03 Srodowisko pracy - oswietlenie elektryczne Rownomiernosc oswietlenia (z obliczen) PN-83/E-04040.03","categories":["environment"],"row_index":122,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa0141","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat zimny","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(-20 – 10) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(-20 – 15) °C"},{"name":"Wilgotność powietrza"},{"name":"Zakres","range":"(25 – 80) %"},{"name":"Prędkość powietrza"},{"name":"Zakres","range":"(0,15 – 5,0) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (-20 – 10) °C\nTemperatura poczernionej kuli\nZakres (-20 – 15) °C\nWilgotność powietrza\nZakres (25 – 80) %\nPrędkość powietrza\nZakres (0,15 – 5,0) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 11079:2008","norm_bases":["PN-EN ISO 11079:2008"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań i Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat zimny Temperatura powietrza\nZakres:\nZakres (-20 – 10) °C\nTemperatura poczernionej kuli\nZakres (-20 – 15) °C\nWilgotność powietrza\nZakres (25 – 80) %\nPrędkość powietrza\nZakres (0,15 – 5,0) m/s\nMetoda pomiarowa bezpośrednia PN-EN ISO 11079:2008 Srodowisko pracy - mikroklimat zimny Temperatura powietrza\nZakres:\nZakres (-20 – 10) °C\nTemperatura poczernionej kuli\nZakres (-20 – 15) °C\nWilgotnosc powietrza\nZakres (25 – 80) %\nPredkosc powietrza\nZakres (0,15 – 5,0) m/s\nMetoda pomiarowa bezposrednia PN-EN ISO 11079:2008","categories":["environment"],"row_index":123,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa0142","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat zimny","methodology":"Wskaźnik IREQmin, Wskaźnik IREQneutral, Wskaźnik twc (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik IREQmin, Wskaźnik IREQneutral, Wskaźnik twc (z obliczeń)","reference":"PN-EN ISO 11079:2008","norm_bases":["PN-EN ISO 11079:2008"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań i Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat zimny Wskaźnik IREQmin, Wskaźnik IREQneutral, Wskaźnik twc (z obliczeń) PN-EN ISO 11079:2008 Srodowisko pracy - mikroklimat zimny Wskaznik IREQmin, Wskaznik IREQneutral, Wskaznik twc (z obliczen) PN-EN ISO 11079:2008","categories":["environment"],"row_index":124,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa0143","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat gorący","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(15 – 50) °C"},{"name":"Temperatura wilgotna naturalna"},{"name":"Zakres","range":"(15 – 50) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(15 – 60) °C"},{"name":"Prędkość powietrza"},{"name":"Zakres","range":"(0,15 – 5,0) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (15 – 50) °C\nTemperatura wilgotna naturalna\nZakres (15 – 50) °C\nTemperatura poczernionej kuli\nZakres (15 – 60) °C\nPrędkość powietrza\nZakres (0,15 – 5,0) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020-04","norm_bases":["PN-EN ISO 7243:2018-01","PN-EN ISO 7243:2018-01/Ap2:2020-04"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań i Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat gorący Temperatura powietrza\nZakres:\nZakres (15 – 50) °C\nTemperatura wilgotna naturalna\nZakres (15 – 50) °C\nTemperatura poczernionej kuli\nZakres (15 – 60) °C\nPrędkość powietrza\nZakres (0,15 – 5,0) m/s\nMetoda pomiarowa bezpośrednia PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020-04 Srodowisko pracy - mikroklimat goracy Temperatura powietrza\nZakres:\nZakres (15 – 50) °C\nTemperatura wilgotna naturalna\nZakres (15 – 50) °C\nTemperatura poczernionej kuli\nZakres (15 – 60) °C\nPredkosc powietrza\nZakres (0,15 – 5,0) m/s\nMetoda pomiarowa bezposrednia PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020-04","categories":["environment"],"row_index":125,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa0144","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat gorący","methodology":"Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń)","reference":"PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020-04","norm_bases":["PN-EN ISO 7243:2018-01","PN-EN ISO 7243:2018-01/Ap2:2020-04"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań i Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat gorący Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń) PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020-04 Srodowisko pracy - mikroklimat goracy Wskaznik WBGT, Wskaznik WBGTeff (z obliczen) PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020-04","categories":["environment"],"row_index":126,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa0145","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Środowisko pracy − mikroklimat umiarkowany","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(10 – 30)°C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(10 – 35)°C"},{"name":"Wilgotność powietrza"},{"name":"Zakres","range":"(25 – 80) %"},{"name":"Prędkość powietrza"},{"name":"Zakres","range":"(0,15 – 1,0) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (10 – 30)°C\nTemperatura poczernionej kuli\nZakres (10 – 35)°C\nWilgotność powietrza\nZakres (25 – 80) %\nPrędkość powietrza\nZakres (0,15 – 1,0) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7730:2006","norm_bases":["PN-EN ISO 7730:2006"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań i Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − mikroklimat umiarkowany Temperatura powietrza\nZakres:\nZakres (10 – 30)°C\nTemperatura poczernionej kuli\nZakres (10 – 35)°C\nWilgotność powietrza\nZakres (25 – 80) %\nPrędkość powietrza\nZakres (0,15 – 1,0) m/s\nMetoda pomiarowa bezpośrednia PN-EN ISO 7730:2006 Srodowisko pracy − mikroklimat umiarkowany Temperatura powietrza\nZakres:\nZakres (10 – 30)°C\nTemperatura poczernionej kuli\nZakres (10 – 35)°C\nWilgotnosc powietrza\nZakres (25 – 80) %\nPredkosc powietrza\nZakres (0,15 – 1,0) m/s\nMetoda pomiarowa bezposrednia PN-EN ISO 7730:2006","categories":["environment"],"row_index":127,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa0146","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Środowisko pracy − mikroklimat umiarkowany","methodology":"Wskaźnik PMV, Wskaźnik PPD (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik PMV, Wskaźnik PPD (z obliczeń)","reference":"PN-EN ISO 7730:2006","norm_bases":["PN-EN ISO 7730:2006"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań i Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − mikroklimat umiarkowany Wskaźnik PMV, Wskaźnik PPD (z obliczeń) PN-EN ISO 7730:2006 Srodowisko pracy − mikroklimat umiarkowany Wskaznik PMV, Wskaznik PPD (z obliczen) PN-EN ISO 7730:2006","categories":["environment"],"row_index":128,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa0147","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń do magnetoterapii","methodology":"Indukcja magnetyczna:","parameters":[{"name":"w zakresie częstotliwości od 10 Hz","range":"do 400 kHz"},{"name":"Zakres","range":"(1,0 – 19000) μT"}],"technique":"Metoda pomiarowa bezpośrednia (uproszczona)","techniques":["Metoda pomiarowa bezpośrednia (uproszczona)"],"computed":[],"activity":"Indukcja magnetyczna:\nZakres:\nw zakresie częstotliwości od 10 Hz do 400 kHz\nZakres (1,0 – 19000) μT\nMetoda pomiarowa bezpośrednia (uproszczona)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), str. 151-180","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), str. 151-180"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań i Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego; Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (tj. Dz. U. z 2018 r. poz. 331)","flexible":false,"search_text":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń do magnetoterapii Indukcja magnetyczna:\nZakres:\nw zakresie częstotliwości od 10 Hz do 400 kHz\nZakres (1,0 – 19000) μT\nMetoda pomiarowa bezpośrednia (uproszczona) Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), str. 151-180 Srodowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzace od urzadzen do magnetoterapii Indukcja magnetyczna:\nZakres:\nw zakresie czestotliwosci od 10 Hz do 400 kHz\nZakres (1,0 – 19000) μT\nMetoda pomiarowa bezposrednia (uproszczona) Podstawy i Metody Oceny Srodowiska Pracy 2016, nr 4 (90), str. 151-180","categories":["environment"],"row_index":129,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa0148","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń do magnetoterapii","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości od 10 Hz","range":"do 400 kHz"},{"name":"(z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 10 Hz do 400 kHz\n(z obliczeń)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), str. 151-180","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), str. 151-180"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań i Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego; Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (tj. Dz. U. z 2018 r. poz. 331)","flexible":false,"search_text":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń do magnetoterapii Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 10 Hz do 400 kHz\n(z obliczeń) Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), str. 151-180 Srodowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzace od urzadzen do magnetoterapii Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 10 Hz do 400 kHz\n(z obliczen) Podstawy i Metody Oceny Srodowiska Pracy 2016, nr 4 (90), str. 151-180","categories":["environment"],"row_index":130,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa0149","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne od instalacji i urządzeń przemysłowych: - urządzenia do grzania dielektrycznego","methodology":"Natężenie pola elektrycznego w zakresie częstotliwości: od 100 kHz do 18 GHz","parameters":[{"name":"Zakres","range":"(0,5 – 1000) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego w zakresie częstotliwości: od 100 kHz do 18 GHz\nZakres (0,5 – 1000) V/m\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego PB/L-100 wydanie 3 z dnia 03.04.2025 r.","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego PB/L-100 wydanie 3 z dnia 03.04.2025 r."],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań i Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne od instalacji i urządzeń przemysłowych: - urządzenia do grzania dielektrycznego Natężenie pola elektrycznego w zakresie częstotliwości: od 100 kHz do 18 GHz\nZakres (0,5 – 1000) V/m\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego PB/L-100 wydanie 3 z dnia 03.04.2025 r. Srodowisko pracy - pole elektromagnetyczne od instalacji i urzadzen przemyslowych: - urzadzenia do grzania dielektrycznego Natezenie pola elektrycznego w zakresie czestotliwosci: od 100 kHz do 18 GHz\nZakres (0,5 – 1000) V/m\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego PB/L-100 wydanie 3 z dnia 03.04.2025 r.","categories":["environment"],"row_index":131,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa014a","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne od instalacji i urządzeń przemysłowych: - urządzenia do grzania dielektrycznego","methodology":"Natężenie pola magnetycznego w zakresie częstotliwości: od 300 kHz do 1 GHz","parameters":[{"name":"Zakres","range":"(0,010 – 16) A/m"}],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego w zakresie częstotliwości: od 300 kHz do 1 GHz\nZakres (0,010 – 16) A/m","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego PB/L-100 wydanie 3 z dnia 03.04.2025 r.","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego PB/L-100 wydanie 3 z dnia 03.04.2025 r."],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań i Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne od instalacji i urządzeń przemysłowych: - urządzenia do grzania dielektrycznego Natężenie pola magnetycznego w zakresie częstotliwości: od 300 kHz do 1 GHz\nZakres (0,010 – 16) A/m PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego PB/L-100 wydanie 3 z dnia 03.04.2025 r. Srodowisko pracy - pole elektromagnetyczne od instalacji i urzadzen przemyslowych: - urzadzenia do grzania dielektrycznego Natezenie pola magnetycznego w zakresie czestotliwosci: od 300 kHz do 1 GHz\nZakres (0,010 – 16) A/m PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego PB/L-100 wydanie 3 z dnia 03.04.2025 r.","categories":["environment"],"row_index":132,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa014b","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Środowisko pracy − pole elektromagnetyczne pochodzące od urządzeń stosowanych w technice medycznej: - diatermie chirurgiczne - diatermie fizykoterapeutyczne","methodology":"Natężenie pola elektrycznego w zakresie częstotliwości: od 100 kHz do 18 GHz","parameters":[{"name":"Zakres","range":"(0,5 – 1000) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego w zakresie częstotliwości: od 100 kHz do 18 GHz\nZakres (0,5 – 1000) V/m\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego PB/L-100 wydanie 3 z dnia 03.04.2025 r.","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego PB/L-100 wydanie 3 z dnia 03.04.2025 r."],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań i Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − pole elektromagnetyczne pochodzące od urządzeń stosowanych w technice medycznej: - diatermie chirurgiczne - diatermie fizykoterapeutyczne Natężenie pola elektrycznego w zakresie częstotliwości: od 100 kHz do 18 GHz\nZakres (0,5 – 1000) V/m\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego PB/L-100 wydanie 3 z dnia 03.04.2025 r. Srodowisko pracy − pole elektromagnetyczne pochodzace od urzadzen stosowanych w technice medycznej: - diatermie chirurgiczne - diatermie fizykoterapeutyczne Natezenie pola elektrycznego w zakresie czestotliwosci: od 100 kHz do 18 GHz\nZakres (0,5 – 1000) V/m\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego PB/L-100 wydanie 3 z dnia 03.04.2025 r.","categories":["environment"],"row_index":133,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa014c","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Środowisko pracy − pole elektromagnetyczne pochodzące od urządzeń stosowanych w technice medycznej: - diatermie chirurgiczne - diatermie fizykoterapeutyczne","methodology":"Natężenie pola magnetycznego w zakresie częstotliwości: od 300 kHz do 1 GHz","parameters":[{"name":"Zakres","range":"(0,010 – 16) A/m"}],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego w zakresie częstotliwości: od 300 kHz do 1 GHz\nZakres (0,010 – 16) A/m","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego PB/L-100 wydanie 3 z dnia 03.04.2025 r.","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego PB/L-100 wydanie 3 z dnia 03.04.2025 r."],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań i Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − pole elektromagnetyczne pochodzące od urządzeń stosowanych w technice medycznej: - diatermie chirurgiczne - diatermie fizykoterapeutyczne Natężenie pola magnetycznego w zakresie częstotliwości: od 300 kHz do 1 GHz\nZakres (0,010 – 16) A/m PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego PB/L-100 wydanie 3 z dnia 03.04.2025 r. Srodowisko pracy − pole elektromagnetyczne pochodzace od urzadzen stosowanych w technice medycznej: - diatermie chirurgiczne - diatermie fizykoterapeutyczne Natezenie pola magnetycznego w zakresie czestotliwosci: od 300 kHz do 1 GHz\nZakres (0,010 – 16) A/m PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego PB/L-100 wydanie 3 z dnia 03.04.2025 r.","categories":["environment"],"row_index":134,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa014d","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Środowisko pracy − pole elektromagnetyczne pochodzące od urządzeń stosowanych w technice medycznej: - diatermie chirurgiczne - diatermie fizykoterapeutyczne","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości od 1","range":"do 3 GHz"},{"name":"(z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 1 do 3 GHz\n(z obliczeń)","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego PB/L-100 wydanie 3 z dnia 03.04.2025 r.","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego PB/L-100 wydanie 3 z dnia 03.04.2025 r."],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań i Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − pole elektromagnetyczne pochodzące od urządzeń stosowanych w technice medycznej: - diatermie chirurgiczne - diatermie fizykoterapeutyczne Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 1 do 3 GHz\n(z obliczeń) PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego PB/L-100 wydanie 3 z dnia 03.04.2025 r. Srodowisko pracy − pole elektromagnetyczne pochodzace od urzadzen stosowanych w technice medycznej: - diatermie chirurgiczne - diatermie fizykoterapeutyczne Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 1 do 3 GHz\n(z obliczen) PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego PB/L-100 wydanie 3 z dnia 03.04.2025 r.","categories":["environment"],"row_index":135,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa014e","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Pobieranie próbek w celu oceny narażenia zawodowego na:","parameters":[{"name":"czynniki pyłowe"},{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna"}],"technique":"Metoda dozymetrii indywidualnej","techniques":["Metoda dozymetrii indywidualnej"],"computed":[],"activity":"Pobieranie próbek w celu oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe\nfrakcja wdychalna\nfrakcja respirabilna\nMetoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002","norm_bases":["PN-Z-04008-7:2002"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań i Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Pobieranie próbek w celu oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe\nfrakcja wdychalna\nfrakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002 Srodowisko pracy - powietrze Pobieranie probek w celu oceny narazenia zawodowego na:\nZakres:\nczynniki pylowe\nfrakcja wdychalna\nfrakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002","categories":["environment"],"row_index":136,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa014f","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Wskaźnik narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PN-Z-04008-7:2002","norm_bases":["PN-Z-04008-7:2002"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań i Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Wskaźnik narażenia (z obliczeń) PN-Z-04008-7:2002 Srodowisko pracy - powietrze Wskaznik narazenia (z obliczen) PN-Z-04008-7:2002","categories":["environment"],"row_index":137,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa0150","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie pyłowych czynników szkodliwych - frakcja wdychalna","parameters":[{"name":"Grafit naturalny"},{"name":"Grafit syntetyczny"},{"name":"Krzemionka bezpostaciowa i syntetyczna"},{"name":"Pyły drewna"},{"name":"Pyły mąki"},{"name":"Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Sadza techniczna"},{"name":"Węglan wapnia"},{"name":"Zakres","range":"(0,15 – 20,00) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych - frakcja wdychalna\nZakres:\nGrafit naturalny\nGrafit syntetyczny\nKrzemionka bezpostaciowa i syntetyczna\nPyły drewna\nPyły mąki\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nSadza techniczna\nWęglan wapnia\nZakres (0,15 – 20,00) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04507:2022-05","PN-Z-04507:2022-05/Ap1:2022-08"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań i Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie pyłowych czynników szkodliwych - frakcja wdychalna\nZakres:\nGrafit naturalny\nGrafit syntetyczny\nKrzemionka bezpostaciowa i syntetyczna\nPyły drewna\nPyły mąki\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nSadza techniczna\nWęglan wapnia\nZakres (0,15 – 20,00) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08 Srodowisko pracy - powietrze Stezenie pylowych czynnikow szkodliwych - frakcja wdychalna\nZakres:\nGrafit naturalny\nGrafit syntetyczny\nKrzemionka bezpostaciowa i syntetyczna\nPyly drewna\nPyly maki\nPyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nSadza techniczna\nWeglan wapnia\nZakres (0,15 – 20,00) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","categories":["environment"],"row_index":138,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa0151","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie pyłowych czynników szkodliwych - frakcja respirabilna","parameters":[{"name":"Grafit naturalny"},{"name":"Krzemionka bezpostaciowa i syntetyczna"},{"name":"Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Zakres","range":"(0,10 – 9,26) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych - frakcja respirabilna\nZakres:\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nZakres (0,10 – 9,26) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04508:2022-05","PN-Z-04508:2022-05/Ap1:2022-08"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań i Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie pyłowych czynników szkodliwych - frakcja respirabilna\nZakres:\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nZakres (0,10 – 9,26) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08 Srodowisko pracy - powietrze Stezenie pylowych czynnikow szkodliwych - frakcja respirabilna\nZakres:\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nZakres (0,10 – 9,26) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","categories":["environment"],"row_index":139,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa0152","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Urządzenie stosowane w stomatologii – aparaty do zdjęć wewnątrzustnych","methodology":"Testy specjalistyczne","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Testy specjalistyczne","reference":"Załącznik nr 1 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. 2022 poz. 2759) PB/L-93 wydanie 3 z dnia 24.02.2023 r.","norm_bases":["Załącznik nr 1 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. 2022 poz. 2759) PB/L-93 wydanie 3 z dnia 24.02.2023 r."],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań Radiacyjnych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenie stosowane w stomatologii – aparaty do zdjęć wewnątrzustnych Testy specjalistyczne Załącznik nr 1 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. 2022 poz. 2759) PB/L-93 wydanie 3 z dnia 24.02.2023 r. Urzadzenie stosowane w stomatologii – aparaty do zdjec wewnatrzustnych Testy specjalistyczne Zalacznik nr 1 do rozporzadzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. 2022 poz. 2759) PB/L-93 wydanie 3 z dnia 24.02.2023 r.","categories":["other"],"row_index":140,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa0153","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Urządzenia stosowane w radiografii ogólnej cyfrowej","methodology":"Testy specjalistyczne","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Testy specjalistyczne","reference":"Załącznik nr 1 i 2 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. z 2022 r. poz. 2759) PB/L-96 wydanie 5 z dnia 19.04.2023 r. PB/L-109 wydanie 1 z dnia 24.02.2023 r. wydanie 1 z dnia 24.02.2023 r.","norm_bases":["Załącznik nr 1 i 2 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. z 2022 r. poz. 2759) PB/L-96 wydanie 5 z dnia 19.04.2023 r. PB/L-109 wydanie 1 z dnia 24.02.2023 r. wydanie 1 z dnia 24.02.2023 r."],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań Radiacyjnych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia stosowane w radiografii ogólnej cyfrowej Testy specjalistyczne Załącznik nr 1 i 2 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. z 2022 r. poz. 2759) PB/L-96 wydanie 5 z dnia 19.04.2023 r. PB/L-109 wydanie 1 z dnia 24.02.2023 r. wydanie 1 z dnia 24.02.2023 r. Urzadzenia stosowane w radiografii ogolnej cyfrowej Testy specjalistyczne Zalacznik nr 1 i 2 do rozporzadzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. z 2022 r. poz. 2759) PB/L-96 wydanie 5 z dnia 19.04.2023 r. PB/L-109 wydanie 1 z dnia 24.02.2023 r. wydanie 1 z dnia 24.02.2023 r.","categories":["other"],"row_index":141,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa0154","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Urządzenie stosowane w stomatologii – aparaty do zdjęć pantomograficznych oraz cefalometrii analogowej","methodology":"Testy specjalistyczne","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Testy specjalistyczne","reference":"Załącznik nr 1 i 2 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. z 2022 r. poz. 2759) PB/L-94 wydanie 4 z dnia 19.04.2023 r. PB/L-109 wydanie 1 z dnia 24.02.2023 r. wydanie 1 z dnia 24.02.2023 r.","norm_bases":["Załącznik nr 1 i 2 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. z 2022 r. poz. 2759) PB/L-94 wydanie 4 z dnia 19.04.2023 r. PB/L-109 wydanie 1 z dnia 24.02.2023 r. wydanie 1 z dnia 24.02.2023 r."],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań Radiacyjnych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenie stosowane w stomatologii – aparaty do zdjęć pantomograficznych oraz cefalometrii analogowej Testy specjalistyczne Załącznik nr 1 i 2 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. z 2022 r. poz. 2759) PB/L-94 wydanie 4 z dnia 19.04.2023 r. PB/L-109 wydanie 1 z dnia 24.02.2023 r. wydanie 1 z dnia 24.02.2023 r. Urzadzenie stosowane w stomatologii – aparaty do zdjec pantomograficznych oraz cefalometrii analogowej Testy specjalistyczne Zalacznik nr 1 i 2 do rozporzadzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. z 2022 r. poz. 2759) PB/L-94 wydanie 4 z dnia 19.04.2023 r. PB/L-109 wydanie 1 z dnia 24.02.2023 r. wydanie 1 z dnia 24.02.2023 r.","categories":["other"],"row_index":142,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa0155","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Urządzenie stosowane w stomatologii – aparaty do zdjęć pantomograficznych oraz cefalometrii cyfrowej","methodology":"Testy specjalistyczne","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Testy specjalistyczne","reference":"Załącznik nr 1 i 2 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. z 2022 r. poz. 2759) PB/L-94 wydanie 4 z dnia 19.04.2023 r. PB/L-109 wydanie 1 z dnia 24.02.2023 r. wydanie 1 z dnia 24.02.2023 r.","norm_bases":["Załącznik nr 1 i 2 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. z 2022 r. poz. 2759) PB/L-94 wydanie 4 z dnia 19.04.2023 r. PB/L-109 wydanie 1 z dnia 24.02.2023 r. wydanie 1 z dnia 24.02.2023 r."],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań Radiacyjnych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenie stosowane w stomatologii – aparaty do zdjęć pantomograficznych oraz cefalometrii cyfrowej Testy specjalistyczne Załącznik nr 1 i 2 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. z 2022 r. poz. 2759) PB/L-94 wydanie 4 z dnia 19.04.2023 r. PB/L-109 wydanie 1 z dnia 24.02.2023 r. wydanie 1 z dnia 24.02.2023 r. Urzadzenie stosowane w stomatologii – aparaty do zdjec pantomograficznych oraz cefalometrii cyfrowej Testy specjalistyczne Zalacznik nr 1 i 2 do rozporzadzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. z 2022 r. poz. 2759) PB/L-94 wydanie 4 z dnia 19.04.2023 r. PB/L-109 wydanie 1 z dnia 24.02.2023 r. wydanie 1 z dnia 24.02.2023 r.","categories":["other"],"row_index":143,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa0156","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Urządzenie stosowane w stomatologicznej tomografii komputerowej wiązki stożkowej","methodology":"Testy specjalistyczne","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Testy specjalistyczne","reference":"Załącznik nr 1 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. z 2022 r. poz. 2759) PB/L-106 wydanie 3 z dnia 24.02.2023 r. wydanie 3 z dnia 24.02.2023 r.","norm_bases":["Załącznik nr 1 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. z 2022 r. poz. 2759) PB/L-106 wydanie 3 z dnia 24.02.2023 r. wydanie 3 z dnia 24.02.2023 r."],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań Radiacyjnych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenie stosowane w stomatologicznej tomografii komputerowej wiązki stożkowej Testy specjalistyczne Załącznik nr 1 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. z 2022 r. poz. 2759) PB/L-106 wydanie 3 z dnia 24.02.2023 r. wydanie 3 z dnia 24.02.2023 r. Urzadzenie stosowane w stomatologicznej tomografii komputerowej wiazki stozkowej Testy specjalistyczne Zalacznik nr 1 do rozporzadzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. z 2022 r. poz. 2759) PB/L-106 wydanie 3 z dnia 24.02.2023 r. wydanie 3 z dnia 24.02.2023 r.","categories":["other"],"row_index":144,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa0157","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Urządzenia stosowane we fluoroskopii i angiografii","methodology":"Testy specjalistyczne","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Testy specjalistyczne","reference":"Załącznik nr 1 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. z 2022 r. poz. 2759) PB/L-97 wydanie 5 z dnia 19.04.2023 r. wydanie 5 z dnia 19.04.2023 r.","norm_bases":["Załącznik nr 1 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. z 2022 r. poz. 2759) PB/L-97 wydanie 5 z dnia 19.04.2023 r. wydanie 5 z dnia 19.04.2023 r."],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań Radiacyjnych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia stosowane we fluoroskopii i angiografii Testy specjalistyczne Załącznik nr 1 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. z 2022 r. poz. 2759) PB/L-97 wydanie 5 z dnia 19.04.2023 r. wydanie 5 z dnia 19.04.2023 r. Urzadzenia stosowane we fluoroskopii i angiografii Testy specjalistyczne Zalacznik nr 1 do rozporzadzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. z 2022 r. poz. 2759) PB/L-97 wydanie 5 z dnia 19.04.2023 r. wydanie 5 z dnia 19.04.2023 r.","categories":["other"],"row_index":145,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa0158","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Monitory stosowane do prezentacji obrazów medycznych","methodology":"Testy specjalistyczne","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Testy specjalistyczne","reference":"Załącznik nr 2 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. z 2022 r. poz. 2759) PB/L-98 wydanie 3 z dnia 24.02.2023 r. wydanie 3 z dnia 24.02.2023 r.","norm_bases":["Załącznik nr 2 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. z 2022 r. poz. 2759) PB/L-98 wydanie 3 z dnia 24.02.2023 r. wydanie 3 z dnia 24.02.2023 r."],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań Radiacyjnych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Monitory stosowane do prezentacji obrazów medycznych Testy specjalistyczne Załącznik nr 2 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. z 2022 r. poz. 2759) PB/L-98 wydanie 3 z dnia 24.02.2023 r. wydanie 3 z dnia 24.02.2023 r. Monitory stosowane do prezentacji obrazow medycznych Testy specjalistyczne Zalacznik nr 2 do rozporzadzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. z 2022 r. poz. 2759) PB/L-98 wydanie 3 z dnia 24.02.2023 r. wydanie 3 z dnia 24.02.2023 r.","categories":["other"],"row_index":146,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa0159","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Promieniowanie jonizujące, Żywność","methodology":"Stężenie aktywności radionuklidu: 137 Cs","parameters":[{"name":"Zakres","range":"(0,2 – 5000) Bq/kg"}],"technique":"Metoda spektometrii promieniowania gamma","techniques":["Metoda spektometrii promieniowania gamma"],"computed":[],"activity":"Stężenie aktywności radionuklidu: 137 Cs\nZakres (0,2 – 5000) Bq/kg\nMetoda spektometrii promieniowania gamma","reference":"PB/L-67 wydanie 3 z dnia 11.03.2024r.","norm_bases":["PB/L-67 wydanie 3 z dnia 11.03.2024r."],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań Radiacyjnych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Promieniowanie jonizujące, Żywność Stężenie aktywności radionuklidu: 137 Cs\nZakres (0,2 – 5000) Bq/kg\nMetoda spektometrii promieniowania gamma PB/L-67 wydanie 3 z dnia 11.03.2024r. Promieniowanie jonizujace, Zywnosc Stezenie aktywnosci radionuklidu: 137 Cs\nZakres (0,2 – 5000) Bq/kg\nMetoda spektometrii promieniowania gamma PB/L-67 wydanie 3 z dnia 11.03.2024r.","categories":["food"],"row_index":147,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa015a","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Kał, wymaz z odbytu, szczep bakteryjny","methodology":"Obecność i identyfikacja pałeczek jelitowych z rodzaju Salmonella i Shigella","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność i identyfikacja pałeczek jelitowych z rodzaju Salmonella i Shigella\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PB/L-09 wydanie 5 z dnia 10.02.2025 r. | na podstawie publikacji metodycznych","norm_bases":["PB/L-09 wydanie 5 z dnia 10.02.2025 r.","na podstawie publikacji metodycznych"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Mikrobiologii i Epidemiologii; Pracownia Bakteriologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kał, wymaz z odbytu, szczep bakteryjny Obecność i identyfikacja pałeczek jelitowych z rodzaju Salmonella i Shigella\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB/L-09 wydanie 5 z dnia 10.02.2025 r. | na podstawie publikacji metodycznych Kal, wymaz z odbytu, szczep bakteryjny Obecnosc i identyfikacja paleczek jelitowych z rodzaju Salmonella i Shigella\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB/L-09 wydanie 5 z dnia 10.02.2025 r. | na podstawie publikacji metodycznych","categories":["microbiology"],"row_index":148,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa015b","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Kał, wymaz z odbytu, szczep bakteryjny","methodology":"Obecność i identyfikacja pałeczek jelitowych z rodzaju Yersinia i Escherichia coli O 157","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność i identyfikacja pałeczek jelitowych z rodzaju Yersinia i Escherichia coli O 157\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PB/L-10 wydanie 5 z dnia 10.02.2025 r. | na podstawie publikacji metodycznych","norm_bases":["PB/L-10 wydanie 5 z dnia 10.02.2025 r.","na podstawie publikacji metodycznych"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Mikrobiologii i Epidemiologii; Pracownia Bakteriologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kał, wymaz z odbytu, szczep bakteryjny Obecność i identyfikacja pałeczek jelitowych z rodzaju Yersinia i Escherichia coli O 157\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB/L-10 wydanie 5 z dnia 10.02.2025 r. | na podstawie publikacji metodycznych Kal, wymaz z odbytu, szczep bakteryjny Obecnosc i identyfikacja paleczek jelitowych z rodzaju Yersinia i Escherichia coli O 157\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB/L-10 wydanie 5 z dnia 10.02.2025 r. | na podstawie publikacji metodycznych","categories":["microbiology"],"row_index":149,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa015c","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Wymaz z gardła i nosa","methodology":"Obecność materiału genetycznego wirusa grypy typu A, B, A(H1N1)pmd09, A(H3N2)","parameters":[],"technique":"Metoda real time RT-PCR","techniques":["Metoda real time RT-PCR"],"computed":[],"activity":"Obecność materiału genetycznego wirusa grypy typu A, B, A(H1N1)pmd09, A(H3N2)\nMetoda real time RT-PCR","reference":"PB/L-111 wydanie 1 z dnia 18.02.2025 r. | na podstawie instrukcji producentów","norm_bases":["PB/L-111 wydanie 1 z dnia 18.02.2025 r.","na podstawie instrukcji producentów"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Mikrobiologii i Epidemiologii; Pracownia Biologii Molekularnej i Serologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wymaz z gardła i nosa Obecność materiału genetycznego wirusa grypy typu A, B, A(H1N1)pmd09, A(H3N2)\nMetoda real time RT-PCR PB/L-111 wydanie 1 z dnia 18.02.2025 r. | na podstawie instrukcji producentów Wymaz z gardla i nosa Obecnosc materialu genetycznego wirusa grypy typu A, B, A(H1N1)pmd09, A(H3N2)\nMetoda real time RT-PCR PB/L-111 wydanie 1 z dnia 18.02.2025 r. | na podstawie instrukcji producentow","categories":["materials"],"row_index":150,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa015d","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Wymaz z gardła i nosa","methodology":"Obecność materiału genetycznego wirusów RSV typu A i B","parameters":[],"technique":"Metoda real time RT-PCR","techniques":["Metoda real time RT-PCR"],"computed":[],"activity":"Obecność materiału genetycznego wirusów RSV typu A i B\nMetoda real time RT-PCR","reference":"PB/L-111 wydanie 1 z dnia 18.02.2025 r. | na podstawie instrukcji producentów","norm_bases":["PB/L-111 wydanie 1 z dnia 18.02.2025 r.","na podstawie instrukcji producentów"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Mikrobiologii i Epidemiologii; Pracownia Biologii Molekularnej i Serologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wymaz z gardła i nosa Obecność materiału genetycznego wirusów RSV typu A i B\nMetoda real time RT-PCR PB/L-111 wydanie 1 z dnia 18.02.2025 r. | na podstawie instrukcji producentów Wymaz z gardla i nosa Obecnosc materialu genetycznego wirusow RSV typu A i B\nMetoda real time RT-PCR PB/L-111 wydanie 1 z dnia 18.02.2025 r. | na podstawie instrukcji producentow","categories":["materials"],"row_index":151,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9770136972b3d89ffa015e","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Wymaz z gardła i nosa","methodology":"Obecność materiału genetycznego koronawirusa SARS-CoV-2","parameters":[],"technique":"Metoda real time RT-PCR","techniques":["Metoda real time RT-PCR"],"computed":[],"activity":"Obecność materiału genetycznego koronawirusa SARS-CoV-2\nMetoda real time RT-PCR","reference":"PB/L-111 wydanie 1 z dnia 18.02.2025 r. | na podstawie instrukcji producentów","norm_bases":["PB/L-111 wydanie 1 z dnia 18.02.2025 r.","na podstawie instrukcji producentów"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Mikrobiologii i Epidemiologii; Pracownia Biologii Molekularnej i Serologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wymaz z gardła i nosa Obecność materiału genetycznego koronawirusa SARS-CoV-2\nMetoda real time RT-PCR PB/L-111 wydanie 1 z dnia 18.02.2025 r. | na podstawie instrukcji producentów Wymaz z gardla i nosa Obecnosc materialu genetycznego koronawirusa SARS-CoV-2\nMetoda real time RT-PCR PB/L-111 wydanie 1 z dnia 18.02.2025 r. | na podstawie instrukcji producentow","categories":["materials"],"row_index":152,"parse_version":4,"parse_source":"agent-claude-code"}],"has_pdf":true}