{"lab":{"_id":"69ad52a3de79e566650fb2bc","accr_number":"AB 538","country":"PL","accr_body":"PCA","address":"W ŁODZI, ul. Wodna 40, 90-046 Łódź","categories":["water","food","microbiology","environment","materials","pharma"],"city":"Łódź","imported_at":"2026-03-08T10:42:43.265Z","methods_count":153,"name":"WOJEWÓDZKA STACJA SANITARNO-EPIDEMIOLOGICZNA","parse_status":"parsed","parse_version":3,"pdf_files":["AB_538.pdf"],"scope_summary":"","search_text":"wojewódzka stacja sanitarno-epidemiologiczna w łodzi, ul. wodna 40, 90-046 łódź other microbiology food pharma materials environment water automotive electronics petro metrology","status":"active","updated_at":"2026-03-08T14:51:24.991Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-17T20:51:01.686Z","location":{"type":"Point","coordinates":[19.456,51.7592]},"email_confidence":"high","email_mx":true,"email_source":"https://www.pca.gov.pl/akredytowane-podmioty/akredytacje-aktywne/laboratoria-badawcze/AB%20538,podmiot.html","fields_of_testing":[{"codes":"C/1; C/18; C/21; C/22; C/28, C/29, C/42, C/49","pl":"Badania chemiczne produktów rolnych, papieru, tektury, wyrobów z tworzyw sztucznych, żywności, wody, wody do spożycia przez ludzi, kosmetyków, materiałów opakowaniowych","en":"Chemical tests of agricultural products, paper, cardboard, plastic products, food, water, drinking water, cosmetics, packaging materials"},{"codes":"C/28/P; C/29/P","pl":"Badania chemiczne i pobieranie próbek wody, wody do spożycia przez ludzi","en":"Chemical tests and sampling of water, drinking water"},{"codes":"D/3","pl":"Badania kliniczne medyczne obiektów i materiałów biologicznych przeznaczonych do badań","en":"Clinical, medical tests of biological items and materials for testing"},{"codes":"G/33","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki szkodliwe i uciążliwe – oświetlenie, hałas, mikroklimat, drgania, pole elekromagnetyczne)","en":"Tests concerning environmental engineering (environmental and climatic) – workplace (harmful and nuisance factors – lighting, noice, microclimate, vibration, electromagnetic field)"}],"issue":{"no":"34","date":"10.06.2026"},"parse_date":"2026-08-17T20:51:01.686Z","parse_source":"agent-claude-code","map_coord":[51.761693,19.476822],"map_geo":"nominatim-street","lab_locations":[{"name":"Dział Laboratoryjny","address":"ul. Wodna 40, 90-046 Łódź","city":"Łódź","postal":"90-046"},{"name":"Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych","address":"ul. Wodna 40, 90-046 Łódź","city":"Łódź","postal":"90-046"},{"name":"Pracownia Badań Mikrobiologicznych","address":"ul. Wodna 40, 90-046 Łódź","city":"Łódź","postal":"90-046"},{"name":"Pracownia Badań Chemicznych","address":"ul. Wodna 40, 90-046 Łódź","city":"Łódź","postal":"90-046"},{"name":"Oddział Laboratoryjny Badań Środowiskowych","address":"ul. Wodna 40, 90-046 Łódź","city":"Łódź","postal":"90-046"},{"name":"Pracownia Badań Biologicznych","address":"ul. Wodna 40, 90-046 Łódź","city":"Łódź","postal":"90-046"},{"name":"Pracownia Badań Fizykochemicznych","address":"ul. Wodna 40, 90-046 Łódź","city":"Łódź","postal":"90-046"},{"name":"Sekcja Badania Wody w Zduńskiej Woli","address":"ul. Łaska 13, 98-220 Zduńska Wola","city":"Zduńska Wola","postal":"98-220"},{"name":"Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych","address":"ul. Wodna 40, 90-046 Łódź","city":"Łódź","postal":"90-046"},{"name":"Pracownia Badań i Pomiarów Środowiska Pracy","address":"ul. Wodna 40, 90-046 Łódź","city":"Łódź","postal":"90-046"},{"name":"Pracownia Badań Radiacyjnych","address":"ul. Wodna 40, 90-046 Łódź","city":"Łódź","postal":"90-046"},{"name":"Oddział Laboratoryjny Mikrobiologii i Epidemiologii","address":"ul. Wodna 40, 90-046 Łódź","city":"Łódź","postal":"90-046"},{"name":"Pracownia Bakteriologii","address":"ul. Wodna 40, 90-046 Łódź","city":"Łódź","postal":"90-046"},{"name":"Pracownia Biologii Molekularnej i Serologii","address":"ul. Wodna 40, 90-046 Łódź","city":"Łódź","postal":"90-046"},{"name":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","address":null,"city":null,"postal":null},{"name":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Mikrobiologicznych","address":null,"city":null,"postal":null},{"name":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań Radiacyjnych","address":null,"city":null,"postal":null},{"name":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań i Pomiarów Środowiska Pracy","address":null,"city":null,"postal":null},{"name":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Biologicznych","address":null,"city":null,"postal":null},{"name":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Fizykochemicznych","address":null,"city":null,"postal":null},{"name":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Fizykochemicznych; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycz","address":null,"city":null,"postal":null},{"name":"Dział Laboratoryjny; Oddział Laboratoryjny Mikrobiologii i Epidemiologii; Pracownia Bakteriologii","address":null,"city":null,"postal":null},{"name":"Dział Laboratoryjny; Oddział Laboratoryjny Mikrobiologii i Epidemiologii; Pracownia Biologii Molekularnej i Serologii","address":null,"city":null,"postal":null}],"scope_format":"PCA::pracownie+elastyczny+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/ed165784833440119c4defab9fca7d93/AB%20538.pdf","has_en":true,"category_counts":{"water":78,"food":36,"microbiology":27,"environment":25,"materials":15,"other":10,"pharma":9},"category_scores":{"water":30.42,"food":6.48,"microbiology":3.65,"environment":3.13,"materials":1.13,"other":0.5,"pharma":0.41},"has_zh":true,"lab_locations_zh":[{"name":"实验室部","address":"ul. Wodna 40, 90-046 Łódź","city":"Łódź","postal":"90-046"},{"name":"Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych","address":"ul. Wodna 40, 90-046 Łódź","city":"Łódź","postal":"90-046"},{"name":"Pracownia Badań Mikrobiologicznych","address":"ul. Wodna 40, 90-046 Łódź","city":"Łódź","postal":"90-046"},{"name":"Pracownia Badań Chemicznych","address":"ul. Wodna 40, 90-046 Łódź","city":"Łódź","postal":"90-046"},{"name":"Oddział Laboratoryjny Badań Środowiskowych","address":"ul. Wodna 40, 90-046 Łódź","city":"Łódź","postal":"90-046"},{"name":"Pracownia Badań Biologicznych","address":"ul. Wodna 40, 90-046 Łódź","city":"Łódź","postal":"90-046"},{"name":"Pracownia Badań Fizykochemicznych","address":"ul. Wodna 40, 90-046 Łódź","city":"Łódź","postal":"90-046"},{"name":"Sekcja Badania Wody w Zduńskiej Woli","address":"ul. Łaska 13, 98-220 Zduńska Wola","city":"Zduńska Wola","postal":"98-220"},{"name":"Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych","address":"ul. Wodna 40, 90-046 Łódź","city":"Łódź","postal":"90-046"},{"name":"工作环境检验与测量室","address":"ul. Wodna 40, 90-046 Łódź","city":"Łódź","postal":"90-046"},{"name":"Pracownia Badań Radiacyjnych","address":"ul. Wodna 40, 90-046 Łódź","city":"Łódź","postal":"90-046"},{"name":"Oddział Laboratoryjny Mikrobiologii i Epidemiologii","address":"ul. Wodna 40, 90-046 Łódź","city":"Łódź","postal":"90-046"},{"name":"Pracownia Bakteriologii","address":"ul. Wodna 40, 90-046 Łódź","city":"Łódź","postal":"90-046"},{"name":"Pracownia Biologii Molekularnej i Serologii","address":"ul. Wodna 40, 90-046 Łódź","city":"Łódź","postal":"90-046"},{"name":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","address":null,"city":null,"postal":null},{"name":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Mikrobiologicznych","address":null,"city":null,"postal":null},{"name":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań Radiacyjnych","address":null,"city":null,"postal":null},{"name":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań i Pomiarów Środowiska Pracy","address":null,"city":null,"postal":null},{"name":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Biologicznych","address":null,"city":null,"postal":null},{"name":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Fizykochemicznych","address":null,"city":null,"postal":null},{"name":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Fizykochemicznych; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycz","address":null,"city":null,"postal":null},{"name":"Dział Laboratoryjny; Oddział Laboratoryjny Mikrobiologii i Epidemiologii; Pracownia Bakteriologii","address":null,"city":null,"postal":null},{"name":"Dział Laboratoryjny; Oddział Laboratoryjny Mikrobiologii i Epidemiologii; Pracownia Biologii Molekularnej i Serologii","address":null,"city":null,"postal":null}]},"methods":[{"_id":"6a837436af14b9c0e7b1f34b","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Żywność E","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i mikroskopowym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i mikroskopowym"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym i mikroskopowym","reference":"Normy","norm_bases":["Normy"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Mikrobiologicznych","lab_address":null,"regulatory_area":"E- Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.\nLista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniona publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym i mikroskopowym Normy Zywnosc E Obecnosc drobnoustrojow\nMetoda hodowlana z potwierdzeniem biochemicznym i mikroskopowym Normy","categories":["food","microbiology"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of microorganisms","search_en":"Food E Presence of microorganisms Culture method with biochemical and microscopic confirmation Normy","technique_en":"Culture method with biochemical and microscopic confirmation","test_object_en":"Food E","search_zh":"食品 E 微生物的检出 培养法（附生化与显微确证） Normy","test_object_zh":"食品 E","methodology_zh":"微生物的检出","technique_zh":"培养法（附生化与显微确证）"},{"_id":"6a837436af14b9c0e7b1f34c","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Żywność E","methodology":"Obecność enterotoksyny gronkowcowej","parameters":[],"technique":"Metoda immunoenzymatyczna (ELFA)","techniques":["Metoda immunoenzymatyczna (ELFA)"],"computed":[],"activity":"Obecność enterotoksyny gronkowcowej\nMetoda immunoenzymatyczna (ELFA)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Mikrobiologicznych","lab_address":null,"regulatory_area":"E- Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.\nLista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniona publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Obecność enterotoksyny gronkowcowej\nMetoda immunoenzymatyczna (ELFA) Normy Zywnosc E Obecnosc enterotoksyny gronkowcowej\nMetoda immunoenzymatyczna (ELFA) Normy","categories":["food"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of staphylococcal enterotoxin","search_en":"Food E Presence of staphylococcal enterotoxin Enzyme immunoassay method (ELFA) Normy","technique_en":"Enzyme immunoassay method (ELFA)","test_object_en":"Food E","search_zh":"食品 E Normy","test_object_zh":"食品 E"},{"_id":"6a837436af14b9c0e7b1f34d","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Żywność E","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda płytkowa (posiew powierzchniowy)"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda płytkowa (posiew powierzchniowy)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Mikrobiologicznych","lab_address":null,"regulatory_area":"E- Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.\nLista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniona publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Liczba drobnoustrojów\nMetoda płytkowa (posiew powierzchniowy) Normy Zywnosc E Liczba drobnoustrojow\nMetoda plytkowa (posiew powierzchniowy) Normy","categories":["food","microbiology"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Microorganism count","search_en":"Food E Microorganism count Plate method (spread plate) Normy","technique_en":"Plate method (spread plate)","test_object_en":"Food E","methodology_zh":"菌落总数","search_zh":"食品 E 菌落总数 平板法（表面涂布） Normy","technique_zh":"平板法（表面涂布）","test_object_zh":"食品 E"},{"_id":"6a837436af14b9c0e7b1f34e","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Żywność E","methodology":"Obecność specyficznego DNA, Escherichia coli oraz Escherichia coli wytwarzających toksynę Shiga (STEC) 0103, 0157, 0111, 026, 0145, 0121, 045, 0104","parameters":[],"technique":"Metoda Real Time PCR","techniques":["Metoda Real Time PCR"],"computed":[],"activity":"Obecność specyficznego DNA, Escherichia coli oraz Escherichia coli wytwarzających toksynę Shiga (STEC) 0103, 0157, 0111, 026, 0145, 0121, 045, 0104\nMetoda Real Time PCR","reference":"Normy","norm_bases":["Normy"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Mikrobiologicznych","lab_address":null,"regulatory_area":"E- Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.\nLista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniona publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Obecność specyficznego DNA, Escherichia coli oraz Escherichia coli wytwarzających toksynę Shiga (STEC) 0103, 0157, 0111, 026, 0145, 0121, 045, 0104\nMetoda Real Time PCR Normy Zywnosc E Obecnosc specyficznego DNA, Escherichia coli oraz Escherichia coli wytwarzajacych toksyne Shiga (STEC) 0103, 0157, 0111, 026, 0145, 0121, 045, 0104\nMetoda Real Time PCR Normy","categories":["food","microbiology"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Food E Real Time PCR method Normy","technique_en":"Real Time PCR method","test_object_en":"Food E","search_zh":"食品 E 实时荧光 PCR 法 Normy","test_object_zh":"食品 E","technique_zh":"实时荧光 PCR 法"},{"_id":"6a837436af14b9c0e7b1f34f","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Żywność E","methodology":"Obecność materiału genetycznego wirusów","parameters":[],"technique":"Metoda Real Time RT-PCR","techniques":["Metoda Real Time RT-PCR"],"computed":[],"activity":"Obecność materiału genetycznego wirusów\nMetoda Real Time RT-PCR","reference":"Normy","norm_bases":["Normy"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Mikrobiologicznych","lab_address":null,"regulatory_area":"E- Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.\nLista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniona publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Obecność materiału genetycznego wirusów\nMetoda Real Time RT-PCR Normy Zywnosc E Obecnosc materialu genetycznego wirusow\nMetoda Real Time RT-PCR Normy","categories":["food","materials"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of viral genetic material","search_en":"Food E Presence of viral genetic material Normy","test_object_en":"Food E","search_zh":"食品 E 病毒遗传物质的检出 Normy","test_object_zh":"食品 E","methodology_zh":"病毒遗传物质的检出"},{"_id":"6a837436af14b9c0e7b1f350","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Żywność E, Obiekty z obszaru produkcji żywności E","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"Normy","norm_bases":["Normy"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Mikrobiologicznych","lab_address":null,"regulatory_area":"E- Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.\nLista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniona publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Obiekty z obszaru produkcji żywności E Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym Normy Zywnosc E, Obiekty z obszaru produkcji zywnosci E Obecnosc drobnoustrojow\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym Normy","categories":["food","microbiology"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of microorganisms","search_en":"Presence of microorganisms Culture method with biochemical and serological confirmation Normy","technique_en":"Culture method with biochemical and serological confirmation","search_zh":"微生物的检出 培养法结合生化与血清学确认 Normy","technique_zh":"培养法结合生化与血清学确认","methodology_zh":"微生物的检出"},{"_id":"6a837436af14b9c0e7b1f351","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Żywność E, Obiekty z obszaru produkcji żywności E","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym","reference":"Normy","norm_bases":["Normy"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Mikrobiologicznych","lab_address":null,"regulatory_area":"E- Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.\nLista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniona publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Obiekty z obszaru produkcji żywności E Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym Normy Zywnosc E, Obiekty z obszaru produkcji zywnosci E Obecnosc drobnoustrojow\nMetoda hodowlana z potwierdzeniem biochemicznym Normy","categories":["food","microbiology"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of microorganisms","search_en":"Presence of microorganisms Culture method with biochemical confirmation Normy","technique_en":"Culture method with biochemical confirmation","search_zh":"微生物的检出 培养法结合生化确认 Normy","technique_zh":"培养法结合生化确认","methodology_zh":"微生物的检出"},{"_id":"6a837436af14b9c0e7b1f352","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Żywność E, Obiekty z obszaru produkcji żywności E","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Mikrobiologicznych","lab_address":null,"regulatory_area":"E- Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.\nLista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniona publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Obiekty z obszaru produkcji żywności E Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny) Normy Zywnosc E, Obiekty z obszaru produkcji zywnosci E Liczba drobnoustrojow\nMetoda plytkowa (posiew wglebny) Normy","categories":["food","microbiology"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Microorganism count","search_en":"Microorganism count Plate method (pour plate) Normy","technique_en":"Plate method (pour plate)","methodology_zh":"菌落总数","search_zh":"菌落总数 平板法（倾注培养） Normy","technique_zh":"平板法（倾注培养）"},{"_id":"6a837436af14b9c0e7b1f353","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Żywność pochodzenia roślinnego","methodology":"Pozostałość ditiokarbaminianów","parameters":[{"name":"Zakres","range":"(0,010 – 10,00) mg/kg"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC/MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC/MS)"],"computed":[],"activity":"Pozostałość ditiokarbaminianów\nZakres (0,010 – 10,00) mg/kg\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC/MS)","reference":"PB/ L- 112 wydanie 2 z dnia 10.03.2025r.","norm_bases":["PB/ L- 112 wydanie 2 z dnia 10.03.2025r."],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Żywność pochodzenia roślinnego Pozostałość ditiokarbaminianów\nZakres (0,010 – 10,00) mg/kg\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC/MS) PB/ L- 112 wydanie 2 z dnia 10.03.2025r. Zywnosc pochodzenia roslinnego Pozostalosc ditiokarbaminianow\nZakres (0,010 – 10,00) mg/kg\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC/MS) PB/ L- 112 wydanie 2 z dnia 10.03.2025r.","categories":["food"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dithiocarbamate residue","parameters_en":[{"name":"Range","range":"(0,010 – 10,00) mg/kg"}],"search_en":"Food of plant origin Dithiocarbamate residue Gas chromatography with mass spectrometry detection (GC/MS) Range PB/ L- 112 wydanie 2 z dnia 10.03.2025r.","technique_en":"Gas chromatography with mass spectrometry detection (GC/MS)","test_object_en":"Food of plant origin","parameters_zh":[{"name":"范围","range":"(0,010 – 10,00) mg/kg"}],"search_zh":"范围 PB/ L- 112 wydanie 2 z dnia 10.03.2025r."},{"_id":"6a837436af14b9c0e7b1f354","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Żywność pochodzenia roślinnego","methodology":"Zawartość miedzi","parameters":[{"name":"Zakres","range":"(5,0 - 100,0) mg/kg"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Zawartość miedzi\nZakres (5,0 - 100,0) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-EN 14084:2004","norm_bases":["PN-EN 14084:2004"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Żywność pochodzenia roślinnego Zawartość miedzi\nZakres (5,0 - 100,0) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN 14084:2004 Zywnosc pochodzenia roslinnego Zawartosc miedzi\nZakres (5,0 - 100,0) mg/kg\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN 14084:2004","categories":["food"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Copper content","parameters_en":[{"name":"Range","range":"(5,0 - 100,0) mg/kg"}],"search_en":"Food of plant origin Copper content Flame atomic absorption spectrometry (FAAS) Range PN-EN 14084:2004","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Food of plant origin","parameters_zh":[{"name":"范围","range":"(5,0 - 100,0) mg/kg"}],"search_zh":"铜含量 火焰原子吸收光谱法（FAAS） 范围 PN-EN 14084:2004","technique_zh":"火焰原子吸收光谱法（FAAS）","methodology_zh":"铜含量"},{"_id":"6a837436af14b9c0e7b1f355","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Świeże ryby, owoce morza i ich przetwory","methodology":"Zawartość histaminy","parameters":[{"name":"Zakres","range":"(15,0 - 480,0) mg/kg"}],"technique":"Metoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC/MS/MS)","techniques":["Metoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC/MS/MS)"],"computed":[],"activity":"Zawartość histaminy\nZakres (15,0 - 480,0) mg/kg\nMetoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC/MS/MS)","reference":"PB/L-113 wydanie 1 z dnia 02.12.2024 r.","norm_bases":["PB/L-113 wydanie 1 z dnia 02.12.2024 r."],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Świeże ryby, owoce morza i ich przetwory Zawartość histaminy\nZakres (15,0 - 480,0) mg/kg\nMetoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC/MS/MS) PB/L-113 wydanie 1 z dnia 02.12.2024 r. Swieze ryby, owoce morza i ich przetwory Zawartosc histaminy\nZakres (15,0 - 480,0) mg/kg\nMetoda chromatografii cieczowej z detekcja tandemowa spektrometria mas (LC/MS/MS) PB/L-113 wydanie 1 z dnia 02.12.2024 r.","categories":["other"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Histamine content","parameters_en":[{"name":"Range","range":"(15,0 - 480,0) mg/kg"}],"search_en":"Fresh fish, seafood and their products Histamine content Liquid chromatography with tandem mass spectrometry detection (LC/MS/MS) Range PB/L-113 wydanie 1 z dnia 02.12.2024 r.","technique_en":"Liquid chromatography with tandem mass spectrometry detection (LC/MS/MS)","test_object_en":"Fresh fish, seafood and their products","parameters_zh":[{"name":"范围","range":"(15,0 - 480,0) mg/kg"}],"search_zh":"组胺含量 液相色谱-串联质谱检测法（LC/MS/MS） 范围 PB/L-113 wydanie 1 z dnia 02.12.2024 r.","methodology_zh":"组胺含量","technique_zh":"液相色谱-串联质谱检测法（LC/MS/MS）"},{"_id":"6a837436af14b9c0e7b1f356","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Kawa herbata, koncentraty spożywcze, mięso i produkty mięsne, drób i produkty drobiowe, mleko i produkty mleczne, napoje bezalkoholowe, napoje alkoholowe, owoce i warzywa, przetwory owocowe, warzywne, warzywno- mięsne, ryby i przetwory rybne, słodycze i wyroby cukiernicze, surowce, przetwory zielarskie, przyprawy, środki specjalnego przeznaczenia żywieniowego, tłuszcze roślinne i zwierzęce, zboża i przetwory zbożowe, żywność mrożona, wyroby garmażeryjne, grzyby, sól, suplementy diety substancje dodatkowe, miód, orzechy i ziarna roślin oleistych, ocet, sosy, cukier, drożdże","methodology":"Zawartość rtęci","parameters":[{"name":"Zakres","range":"(0,0005 – 15) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)"],"computed":[],"activity":"Zawartość rtęci\nZakres (0,0005 – 15) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"PB/L-01 wydanie 5 z dnia 16.07.2021 r.","norm_bases":["PB/L-01 wydanie 5 z dnia 16.07.2021 r."],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kawa herbata, koncentraty spożywcze, mięso i produkty mięsne, drób i produkty drobiowe, mleko i produkty mleczne, napoje bezalkoholowe, napoje alkoholowe, owoce i warzywa, przetwory owocowe, warzywne, warzywno- mięsne, ryby i przetwory rybne, słodycze i wyroby cukiernicze, surowce, przetwory zielarskie, przyprawy, środki specjalnego przeznaczenia żywieniowego, tłuszcze roślinne i zwierzęce, zboża i przetwory zbożowe, żywność mrożona, wyroby garmażeryjne, grzyby, sól, suplementy diety substancje dodatkowe, miód, orzechy i ziarna roślin oleistych, ocet, sosy, cukier, drożdże Zawartość rtęci\nZakres (0,0005 – 15) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PB/L-01 wydanie 5 z dnia 16.07.2021 r. Kawa herbata, koncentraty spozywcze, mieso i produkty miesne, drob i produkty drobiowe, mleko i produkty mleczne, napoje bezalkoholowe, napoje alkoholowe, owoce i warzywa, przetwory owocowe, warzywne, warzywno- miesne, ryby i przetwory rybne, slodycze i wyroby cukiernicze, surowce, przetwory zielarskie, przyprawy, srodki specjalnego przeznaczenia zywieniowego, tluszcze roslinne i zwierzece, zboza i przetwory zbozowe, zywnosc mrozona, wyroby garmazeryjne, grzyby, sol, suplementy diety substancje dodatkowe, miod, orzechy i ziarna roslin oleistych, ocet, sosy, cukier, drozdze Zawartosc rteci\nZakres (0,0005 – 15) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PB/L-01 wydanie 5 z dnia 16.07.2021 r.","categories":["food","microbiology","pharma"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury content","parameters_en":[{"name":"Range","range":"(0,0005 – 15) mg/kg"}],"search_en":"Coffee tea, food concentrates, meat and meat products, poultry and poultry products, milk and milk products, non-alcoholic beverages, alcoholic beverages, fruit and vegetables, fruit, vegetable and vegetable-meat preserves, fish and fish products, sweets and confectionery, raw materials, herbal preparations, spices, foodstuffs for particular nutritional uses, vegetable and animal fats, cereals and cereal products, frozen food, delicatessen products, mushrooms, salt, food supplements food additives, honey, nuts and oilseeds, vinegar, sauces, sugar, yeasts Mercury content Cold vapour atomic absorption spectrometry (CVAAS) Range PB/L-01 wydanie 5 z dnia 16.07.2021 r.","technique_en":"Cold vapour atomic absorption spectrometry (CVAAS)","test_object_en":"Coffee tea, food concentrates, meat and meat products, poultry and poultry products, milk and milk products, non-alcoholic beverages, alcoholic beverages, fruit and vegetables, fruit, vegetable and vegetable-meat preserves, fish and fish products, sweets and confectionery, raw materials, herbal preparations, spices, foodstuffs for particular nutritional uses, vegetable and animal fats, cereals and cereal products, frozen food, delicatessen products, mushrooms, salt, food supplements food additives, honey, nuts and oilseeds, vinegar, sauces, sugar, yeasts","methodology_zh":"汞含量","parameters_zh":[{"name":"范围","range":"(0,0005 – 15) mg/kg"}],"search_zh":"汞含量 冷蒸气原子吸收光谱法（CVAAS） 范围 PB/L-01 wydanie 5 z dnia 16.07.2021 r.","technique_zh":"冷蒸气原子吸收光谱法（CVAAS）"},{"_id":"6a837436af14b9c0e7b1f357","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Kawa herbata, koncentraty spożywcze, mięso i produkty mięsne, drób i produkty drobiowe, mleko i produkty mleczne, napoje bezalkoholowe, napoje alkoholowe, owoce i warzywa, przetwory owocowe, warzywne, warzywno- mięsne, ryby i przetwory rybne, słodycze i wyroby cukiernicze, surowce, przetwory zielarskie, przyprawy, środki specjalnego przeznaczenia żywieniowego, tłuszcze roślinne i zwierzęce, zboża i przetwory zbożowe, żywność mrożona, wyroby garmażeryjne, grzyby, sól, suplementy diety substancje dodatkowe, miód, orzechy i ziarna roślin oleistych, ocet, sosy, cukier, drożdże","methodology":"Zawartość arsenu","parameters":[{"name":"Zakres","range":"(0,01 – 25,00) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generacją wodorków (HGAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generacją wodorków (HGAAS)"],"computed":[],"activity":"Zawartość arsenu\nZakres (0,01 – 25,00) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generacją wodorków (HGAAS)","reference":"Wydawnictwo Metodyczne Państwowego Zakładu Higieny Warszawa 2005 r.","norm_bases":["Wydawnictwo Metodyczne Państwowego Zakładu Higieny Warszawa 2005 r."],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kawa herbata, koncentraty spożywcze, mięso i produkty mięsne, drób i produkty drobiowe, mleko i produkty mleczne, napoje bezalkoholowe, napoje alkoholowe, owoce i warzywa, przetwory owocowe, warzywne, warzywno- mięsne, ryby i przetwory rybne, słodycze i wyroby cukiernicze, surowce, przetwory zielarskie, przyprawy, środki specjalnego przeznaczenia żywieniowego, tłuszcze roślinne i zwierzęce, zboża i przetwory zbożowe, żywność mrożona, wyroby garmażeryjne, grzyby, sól, suplementy diety substancje dodatkowe, miód, orzechy i ziarna roślin oleistych, ocet, sosy, cukier, drożdże Zawartość arsenu\nZakres (0,01 – 25,00) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generacją wodorków (HGAAS) Wydawnictwo Metodyczne Państwowego Zakładu Higieny Warszawa 2005 r. Kawa herbata, koncentraty spozywcze, mieso i produkty miesne, drob i produkty drobiowe, mleko i produkty mleczne, napoje bezalkoholowe, napoje alkoholowe, owoce i warzywa, przetwory owocowe, warzywne, warzywno- miesne, ryby i przetwory rybne, slodycze i wyroby cukiernicze, surowce, przetwory zielarskie, przyprawy, srodki specjalnego przeznaczenia zywieniowego, tluszcze roslinne i zwierzece, zboza i przetwory zbozowe, zywnosc mrozona, wyroby garmazeryjne, grzyby, sol, suplementy diety substancje dodatkowe, miod, orzechy i ziarna roslin oleistych, ocet, sosy, cukier, drozdze Zawartosc arsenu\nZakres (0,01 – 25,00) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generacja wodorkow (HGAAS) Wydawnictwo Metodyczne Panstwowego Zakladu Higieny Warszawa 2005 r.","categories":["food","microbiology","pharma"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Arsenic content","parameters_en":[{"name":"Range","range":"(0,01 – 25,00) mg/kg"}],"search_en":"Coffee tea, food concentrates, meat and meat products, poultry and poultry products, milk and milk products, non-alcoholic beverages, alcoholic beverages, fruit and vegetables, fruit, vegetable and vegetable-meat preserves, fish and fish products, sweets and confectionery, raw materials, herbal preparations, spices, foodstuffs for particular nutritional uses, vegetable and animal fats, cereals and cereal products, frozen food, delicatessen products, mushrooms, salt, food supplements food additives, honey, nuts and oilseeds, vinegar, sauces, sugar, yeasts Arsenic content Hydride generation atomic absorption spectrometry (HGAAS) Range Wydawnictwo Metodyczne Państwowego Zakładu Higieny Warszawa 2005 r.","technique_en":"Hydride generation atomic absorption spectrometry (HGAAS)","test_object_en":"Coffee tea, food concentrates, meat and meat products, poultry and poultry products, milk and milk products, non-alcoholic beverages, alcoholic beverages, fruit and vegetables, fruit, vegetable and vegetable-meat preserves, fish and fish products, sweets and confectionery, raw materials, herbal preparations, spices, foodstuffs for particular nutritional uses, vegetable and animal fats, cereals and cereal products, frozen food, delicatessen products, mushrooms, salt, food supplements food additives, honey, nuts and oilseeds, vinegar, sauces, sugar, yeasts","parameters_zh":[{"name":"范围","range":"(0,01 – 25,00) mg/kg"}],"search_zh":"砷含量 氢化物发生原子吸收光谱法（HGAAS） 范围 Wydawnictwo Metodyczne Państwowego Zakładu Higieny Warszawa 2005 r.","methodology_zh":"砷含量","technique_zh":"氢化物发生原子吸收光谱法（HGAAS）"},{"_id":"6a837436af14b9c0e7b1f358","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Substancje dodatkowe, Suplementy diety, Kawa herbata, koncentraty spożywcze, mięso i produkty mięsne, drób i produkty drobiowe, mleko i produkty mleczne, owoce i warzywa, przetwory owocowe, warzywne, warzywno-mięsne, ryby i przetwory rybne, słodycze i wyroby cukiernicze, surowce, przetwory zielarskie, przyprawy, środki specjalnego przeznaczenia żywieniowego, zboża i przetwory zbożowe, żywność mrożona, wyroby garmażeryjne, grzyby, sól, miód, orzechy i ziarna roślin oleistych, ocet, sosy, cukier, drożdże","methodology":"Zawartość ołowiu","parameters":[{"name":"Zakres","range":"(0,01 – 20,0) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)"],"computed":[],"activity":"Zawartość ołowiu\nZakres (0,01 – 20,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","reference":"PN-EN 14083:2004","norm_bases":["PN-EN 14083:2004"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Substancje dodatkowe, Suplementy diety, Kawa herbata, koncentraty spożywcze, mięso i produkty mięsne, drób i produkty drobiowe, mleko i produkty mleczne, owoce i warzywa, przetwory owocowe, warzywne, warzywno-mięsne, ryby i przetwory rybne, słodycze i wyroby cukiernicze, surowce, przetwory zielarskie, przyprawy, środki specjalnego przeznaczenia żywieniowego, zboża i przetwory zbożowe, żywność mrożona, wyroby garmażeryjne, grzyby, sól, miód, orzechy i ziarna roślin oleistych, ocet, sosy, cukier, drożdże Zawartość ołowiu\nZakres (0,01 – 20,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS) PN-EN 14083:2004 Substancje dodatkowe, Suplementy diety, Kawa herbata, koncentraty spozywcze, mieso i produkty miesne, drob i produkty drobiowe, mleko i produkty mleczne, owoce i warzywa, przetwory owocowe, warzywne, warzywno-miesne, ryby i przetwory rybne, slodycze i wyroby cukiernicze, surowce, przetwory zielarskie, przyprawy, srodki specjalnego przeznaczenia zywieniowego, zboza i przetwory zbozowe, zywnosc mrozona, wyroby garmazeryjne, grzyby, sol, miod, orzechy i ziarna roslin oleistych, ocet, sosy, cukier, drozdze Zawartosc olowiu\nZakres (0,01 – 20,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z atomizacja elektrotermiczna (ETAAS) PN-EN 14083:2004","categories":["food","microbiology","pharma"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Lead content","parameters_en":[{"name":"Range","range":"(0,01 – 20,0) mg/kg"}],"search_en":"Food additives, Food supplements, Coffee tea, food concentrates, meat and meat products, poultry and poultry products, milk and milk products, fruit and vegetables, fruit, vegetable and vegetable-meat products, fish and fish products, sweets and confectionery products, raw materials, herbal products, spices, foodstuffs for particular nutritional uses, cereals and cereal products, frozen food, delicatessen products, mushrooms, salt, honey, nuts and oilseeds, vinegar, sauces, sugar, yeast Lead content Electrothermal atomization atomic absorption spectrometry (ETAAS) Range PN-EN 14083:2004","technique_en":"Electrothermal atomization atomic absorption spectrometry (ETAAS)","test_object_en":"Food additives, Food supplements, Coffee tea, food concentrates, meat and meat products, poultry and poultry products, milk and milk products, fruit and vegetables, fruit, vegetable and vegetable-meat products, fish and fish products, sweets and confectionery products, raw materials, herbal products, spices, foodstuffs for particular nutritional uses, cereals and cereal products, frozen food, delicatessen products, mushrooms, salt, honey, nuts and oilseeds, vinegar, sauces, sugar, yeast","parameters_zh":[{"name":"范围","range":"(0,01 – 20,0) mg/kg"}],"search_zh":"铅含量 电热原子化原子吸收光谱法（ETAAS） 范围 PN-EN 14083:2004","technique_zh":"电热原子化原子吸收光谱法（ETAAS）","methodology_zh":"铅含量"},{"_id":"6a837436af14b9c0e7b1f359","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Substancje dodatkowe, Suplementy diety, Kawa herbata, koncentraty spożywcze, mięso i produkty mięsne, drób i produkty drobiowe, mleko i produkty mleczne, owoce i warzywa, przetwory owocowe, warzywne, warzywno-mięsne, ryby i przetwory rybne, słodycze i wyroby cukiernicze, surowce, przetwory zielarskie, przyprawy, środki specjalnego przeznaczenia żywieniowego, zboża i przetwory zbożowe, żywność mrożona, wyroby garmażeryjne, grzyby, sól, miód, orzechy i ziarna roślin oleistych, ocet, sosy, cukier, drożdże","methodology":"Zawartość kadmu","parameters":[{"name":"Zakres","range":"(0,002 – 20,0) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)"],"computed":[],"activity":"Zawartość kadmu\nZakres (0,002 – 20,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","reference":"PN-EN 14083:2004","norm_bases":["PN-EN 14083:2004"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Substancje dodatkowe, Suplementy diety, Kawa herbata, koncentraty spożywcze, mięso i produkty mięsne, drób i produkty drobiowe, mleko i produkty mleczne, owoce i warzywa, przetwory owocowe, warzywne, warzywno-mięsne, ryby i przetwory rybne, słodycze i wyroby cukiernicze, surowce, przetwory zielarskie, przyprawy, środki specjalnego przeznaczenia żywieniowego, zboża i przetwory zbożowe, żywność mrożona, wyroby garmażeryjne, grzyby, sól, miód, orzechy i ziarna roślin oleistych, ocet, sosy, cukier, drożdże Zawartość kadmu\nZakres (0,002 – 20,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS) PN-EN 14083:2004 Substancje dodatkowe, Suplementy diety, Kawa herbata, koncentraty spozywcze, mieso i produkty miesne, drob i produkty drobiowe, mleko i produkty mleczne, owoce i warzywa, przetwory owocowe, warzywne, warzywno-miesne, ryby i przetwory rybne, slodycze i wyroby cukiernicze, surowce, przetwory zielarskie, przyprawy, srodki specjalnego przeznaczenia zywieniowego, zboza i przetwory zbozowe, zywnosc mrozona, wyroby garmazeryjne, grzyby, sol, miod, orzechy i ziarna roslin oleistych, ocet, sosy, cukier, drozdze Zawartosc kadmu\nZakres (0,002 – 20,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z atomizacja elektrotermiczna (ETAAS) PN-EN 14083:2004","categories":["food","microbiology","pharma"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Cadmium content","parameters_en":[{"name":"Range","range":"(0,002 – 20,0) mg/kg"}],"search_en":"Food additives, Food supplements, Coffee tea, food concentrates, meat and meat products, poultry and poultry products, milk and milk products, fruit and vegetables, fruit, vegetable and vegetable-meat products, fish and fish products, sweets and confectionery products, raw materials, herbal products, spices, foodstuffs for particular nutritional uses, cereals and cereal products, frozen food, delicatessen products, mushrooms, salt, honey, nuts and oilseeds, vinegar, sauces, sugar, yeast Cadmium content Electrothermal atomization atomic absorption spectrometry (ETAAS) Range PN-EN 14083:2004","technique_en":"Electrothermal atomization atomic absorption spectrometry (ETAAS)","test_object_en":"Food additives, Food supplements, Coffee tea, food concentrates, meat and meat products, poultry and poultry products, milk and milk products, fruit and vegetables, fruit, vegetable and vegetable-meat products, fish and fish products, sweets and confectionery products, raw materials, herbal products, spices, foodstuffs for particular nutritional uses, cereals and cereal products, frozen food, delicatessen products, mushrooms, salt, honey, nuts and oilseeds, vinegar, sauces, sugar, yeast","parameters_zh":[{"name":"范围","range":"(0,002 – 20,0) mg/kg"}],"search_zh":"镉含量 电热原子化原子吸收光谱法（ETAAS） 范围 PN-EN 14083:2004","technique_zh":"电热原子化原子吸收光谱法（ETAAS）","methodology_zh":"镉含量"},{"_id":"6a837436af14b9c0e7b1f35a","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Konserwy mięsne, drobiowe, mleko i produkty mleczne w puszkach, napoje bezalkoholowe w puszkach, owoce i warzywa, przetwory owocowe, warzywne, warzywno-mięsne w puszkach, konserwy rybne, środki specjalnego przeznaczenia żywieniowego w puszkach, Suplementy diety, Substancje dodatkowe","methodology":"Zawartość cyny","parameters":[{"name":"Zakres","range":"(2 – 500) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)"],"computed":[],"activity":"Zawartość cyny\nZakres (2 – 500) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","reference":"PN-EN 15764:2010","norm_bases":["PN-EN 15764:2010"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Konserwy mięsne, drobiowe, mleko i produkty mleczne w puszkach, napoje bezalkoholowe w puszkach, owoce i warzywa, przetwory owocowe, warzywne, warzywno-mięsne w puszkach, konserwy rybne, środki specjalnego przeznaczenia żywieniowego w puszkach, Suplementy diety, Substancje dodatkowe Zawartość cyny\nZakres (2 – 500) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS) PN-EN 15764:2010 Konserwy miesne, drobiowe, mleko i produkty mleczne w puszkach, napoje bezalkoholowe w puszkach, owoce i warzywa, przetwory owocowe, warzywne, warzywno-miesne w puszkach, konserwy rybne, srodki specjalnego przeznaczenia zywieniowego w puszkach, Suplementy diety, Substancje dodatkowe Zawartosc cyny\nZakres (2 – 500) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z atomizacja elektrotermiczna (ETAAS) PN-EN 15764:2010","categories":["food","pharma"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Tin content","parameters_en":[{"name":"Range","range":"(2 – 500) mg/kg"}],"search_en":"Canned meat, poultry, canned milk and dairy products, canned non-alcoholic beverages, fruit and vegetables, canned fruit, vegetable and vegetable-meat products, canned fish, canned foodstuffs for particular nutritional uses, Dietary supplements, Food additives Tin content Electrothermal atomization atomic absorption spectrometry (ETAAS) Range PN-EN 15764:2010","technique_en":"Electrothermal atomization atomic absorption spectrometry (ETAAS)","test_object_en":"Canned meat, poultry, canned milk and dairy products, canned non-alcoholic beverages, fruit and vegetables, canned fruit, vegetable and vegetable-meat products, canned fish, canned foodstuffs for particular nutritional uses, Dietary supplements, Food additives","parameters_zh":[{"name":"范围","range":"(2 – 500) mg/kg"}],"search_zh":"锡含量 电热原子化原子吸收光谱法（ETAAS） 范围 PN-EN 15764:2010","technique_zh":"电热原子化原子吸收光谱法（ETAAS）","methodology_zh":"锡含量"},{"_id":"6a837436af14b9c0e7b1f35b","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Mięso, podroby i produkty mięsne, drób, podroby drobiowe, produkty drobiarskie, jaja i produkty jajeczne, ryby i owoce morza oraz ich przetwory, mleko i przetwory mleczne, ziarno zbóż i przetwory zbożowe, wyroby cukiernicze, orzechy i ziarna roślin oleistych, zioła i przyprawy, środki spożywcze specjalnego przeznaczenia, cukier, miód, warzywa i ich przetwory, owoce i ich przetwory, grzyby, drożdże, napoje alkoholowe i bezalkoholowe, tłuszcze roślinne, ocet, herbata, herbata ziołowa i owocowa, kawa, suplementy diety","methodology":"Zawartość niklu","parameters":[{"name":"Zakres","range":"(0,05 – 200,00) mg/kg"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Zawartość niklu\nZakres (0,05 – 200,00) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PB/L- 105 wydanie 3 z dnia 02.02.2022r.","norm_bases":["PB/L- 105 wydanie 3 z dnia 02.02.2022r."],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso, podroby i produkty mięsne, drób, podroby drobiowe, produkty drobiarskie, jaja i produkty jajeczne, ryby i owoce morza oraz ich przetwory, mleko i przetwory mleczne, ziarno zbóż i przetwory zbożowe, wyroby cukiernicze, orzechy i ziarna roślin oleistych, zioła i przyprawy, środki spożywcze specjalnego przeznaczenia, cukier, miód, warzywa i ich przetwory, owoce i ich przetwory, grzyby, drożdże, napoje alkoholowe i bezalkoholowe, tłuszcze roślinne, ocet, herbata, herbata ziołowa i owocowa, kawa, suplementy diety Zawartość niklu\nZakres (0,05 – 200,00) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB/L- 105 wydanie 3 z dnia 02.02.2022r. Mieso, podroby i produkty miesne, drob, podroby drobiowe, produkty drobiarskie, jaja i produkty jajeczne, ryby i owoce morza oraz ich przetwory, mleko i przetwory mleczne, ziarno zboz i przetwory zbozowe, wyroby cukiernicze, orzechy i ziarna roslin oleistych, ziola i przyprawy, srodki spozywcze specjalnego przeznaczenia, cukier, miod, warzywa i ich przetwory, owoce i ich przetwory, grzyby, drozdze, napoje alkoholowe i bezalkoholowe, tluszcze roslinne, ocet, herbata, herbata ziolowa i owocowa, kawa, suplementy diety Zawartosc niklu\nZakres (0,05 – 200,00) mg/kg\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB/L- 105 wydanie 3 z dnia 02.02.2022r.","categories":["food","microbiology","pharma"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nickel content","parameters_en":[{"name":"Range","range":"(0,05 – 200,00) mg/kg"}],"search_en":"Meat, offal and meat products, poultry, poultry offal, poultry products, eggs and egg products, fish and seafood and their products, milk and dairy products, cereal grain and cereal products, confectionery products, nuts and oilseeds, herbs and spices, foodstuffs for particular nutritional uses, sugar, honey, vegetables and their products, fruit and their products, mushrooms, yeast, alcoholic and non-alcoholic beverages, vegetable fats, vinegar, tea, herbal and fruit tea, coffee, food supplements Nickel content Flame atomic absorption spectrometry (FAAS) Range PB/L- 105 wydanie 3 z dnia 02.02.2022r.","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Meat, offal and meat products, poultry, poultry offal, poultry products, eggs and egg products, fish and seafood and their products, milk and dairy products, cereal grain and cereal products, confectionery products, nuts and oilseeds, herbs and spices, foodstuffs for particular nutritional uses, sugar, honey, vegetables and their products, fruit and their products, mushrooms, yeast, alcoholic and non-alcoholic beverages, vegetable fats, vinegar, tea, herbal and fruit tea, coffee, food supplements","parameters_zh":[{"name":"范围","range":"(0,05 – 200,00) mg/kg"}],"search_zh":"镍含量 火焰原子吸收光谱法（FAAS） 范围 PB/L- 105 wydanie 3 z dnia 02.02.2022r.","technique_zh":"火焰原子吸收光谱法（FAAS）","methodology_zh":"镍含量"},{"_id":"6a837436af14b9c0e7b1f35c","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Ryby, przetwory rybne i owoce morza, zboża i produkty zbożowe, owoce i warzywa, grzyby, przyprawy i zioła, nasiona roślin oleistych i orzechy","methodology":"Zawartość arsenu nieorganicznego.","parameters":[{"name":"Zakres","range":"(0,025 – 2,5) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generacją wodorków (HGAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generacją wodorków (HGAAS)"],"computed":[],"activity":"Zawartość arsenu nieorganicznego.\nZakres (0,025 – 2,5) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generacją wodorków (HGAAS)","reference":"PB/L-110 wyd. 1 z dnia 10.01.2025r.","norm_bases":["PB/L-110 wyd. 1 z dnia 10.01.2025r."],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ryby, przetwory rybne i owoce morza, zboża i produkty zbożowe, owoce i warzywa, grzyby, przyprawy i zioła, nasiona roślin oleistych i orzechy Zawartość arsenu nieorganicznego.\nZakres (0,025 – 2,5) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generacją wodorków (HGAAS) PB/L-110 wyd. 1 z dnia 10.01.2025r. Ryby, przetwory rybne i owoce morza, zboza i produkty zbozowe, owoce i warzywa, grzyby, przyprawy i ziola, nasiona roslin oleistych i orzechy Zawartosc arsenu nieorganicznego.\nZakres (0,025 – 2,5) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generacja wodorkow (HGAAS) PB/L-110 wyd. 1 z dnia 10.01.2025r.","categories":["microbiology"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,025 – 2,5) mg/kg"}],"search_en":"Hydride generation atomic absorption spectrometry (HGAAS) Range PB/L-110 wyd. 1 z dnia 10.01.2025r.","technique_en":"Hydride generation atomic absorption spectrometry (HGAAS)","parameters_zh":[{"name":"范围","range":"(0,025 – 2,5) mg/kg"}],"search_zh":"氢化物发生原子吸收光谱法（HGAAS） 范围 PB/L-110 wyd. 1 z dnia 10.01.2025r.","technique_zh":"氢化物发生原子吸收光谱法（HGAAS）"},{"_id":"6a837436af14b9c0e7b1f35d","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Soki i napoje bezalkoholowe. Żywność dla niemowląt i małych dzieci oraz środki spożywcze specjalnego przeznaczenia medycznego.","methodology":"Zawartość arsenu nieorganicznego.","parameters":[{"name":"Zakres","range":"(0,010 – 0,25) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generacją wodorków (HGAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generacją wodorków (HGAAS)"],"computed":[],"activity":"Zawartość arsenu nieorganicznego.\nZakres (0,010 – 0,25) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generacją wodorków (HGAAS)","reference":"PB/L-110 wyd. 1 z dnia 10.01.2025r.","norm_bases":["PB/L-110 wyd. 1 z dnia 10.01.2025r."],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Soki i napoje bezalkoholowe. Żywność dla niemowląt i małych dzieci oraz środki spożywcze specjalnego przeznaczenia medycznego. Zawartość arsenu nieorganicznego.\nZakres (0,010 – 0,25) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generacją wodorków (HGAAS) PB/L-110 wyd. 1 z dnia 10.01.2025r. Soki i napoje bezalkoholowe. Zywnosc dla niemowlat i malych dzieci oraz srodki spozywcze specjalnego przeznaczenia medycznego. Zawartosc arsenu nieorganicznego.\nZakres (0,010 – 0,25) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generacja wodorkow (HGAAS) PB/L-110 wyd. 1 z dnia 10.01.2025r.","categories":["food"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,010 – 0,25) mg/kg"}],"search_en":"Hydride generation atomic absorption spectrometry (HGAAS) Range PB/L-110 wyd. 1 z dnia 10.01.2025r.","technique_en":"Hydride generation atomic absorption spectrometry (HGAAS)","parameters_zh":[{"name":"范围","range":"(0,010 – 0,25) mg/kg"}],"search_zh":"氢化物发生原子吸收光谱法（HGAAS） 范围 PB/L-110 wyd. 1 z dnia 10.01.2025r.","technique_zh":"氢化物发生原子吸收光谱法（HGAAS）"},{"_id":"6a837436af14b9c0e7b1f35e","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość metali szkodliwych dla zdrowia","parameters":[],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"computed":[],"activity":"Zawartość metali szkodliwych dla zdrowia\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":"E- Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.\nLista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniona publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Zawartość metali szkodliwych dla zdrowia\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) Normy Zywnosc E Zawartosc metali szkodliwych dla zdrowia\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) Normy","categories":["materials","food"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of metals harmful to health","search_en":"Food E Content of metals harmful to health Inductively coupled plasma mass spectrometry (ICP-MS) Normy","technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","test_object_en":"Food E","search_zh":"食品 E 电感耦合等离子体质谱法（ICP-MS） Normy","technique_zh":"电感耦合等离子体质谱法（ICP-MS）","test_object_zh":"食品 E"},{"_id":"6a837436af14b9c0e7b1f35f","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Żywność pochodzenia roślinnego, produkty rolne E","methodology":"Pozostałość pestycydów","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC/MS/MS)","techniques":["Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC/MS/MS)"],"computed":[],"activity":"Pozostałość pestycydów\nMetoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC/MS/MS)","reference":"PN-EN 15662","norm_bases":["PN-EN 15662"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":"E- Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.\nLista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniona publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność pochodzenia roślinnego, produkty rolne E Pozostałość pestycydów\nMetoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC/MS/MS) PN-EN 15662 Zywnosc pochodzenia roslinnego, produkty rolne E Pozostalosc pestycydow\nMetoda chromatografii gazowej z detekcja tandemowa spektrometria mas (GC/MS/MS) PN-EN 15662","categories":["food"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Pesticide residue","search_en":"Food of plant origin, agricultural products E Pesticide residue Gas chromatography with tandem mass spectrometry detection (GC/MS/MS) PN-EN 15662","technique_en":"Gas chromatography with tandem mass spectrometry detection (GC/MS/MS)","test_object_en":"Food of plant origin, agricultural products E","methodology_zh":"农药残留","search_zh":"植物源食品、农产品 E 农药残留 PN-EN 15662","test_object_zh":"植物源食品、农产品 E"},{"_id":"6a837436af14b9c0e7b1f360","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Żywność pochodzenia roślinnego, produkty rolne E","methodology":"Pozostałość pestycydów","parameters":[],"technique":"Metoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC/MS/MS)","techniques":["Metoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC/MS/MS)"],"computed":[],"activity":"Pozostałość pestycydów\nMetoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC/MS/MS)","reference":"PN-EN 15662","norm_bases":["PN-EN 15662"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":"E- Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.\nLista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniona publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność pochodzenia roślinnego, produkty rolne E Pozostałość pestycydów\nMetoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC/MS/MS) PN-EN 15662 Zywnosc pochodzenia roslinnego, produkty rolne E Pozostalosc pestycydow\nMetoda chromatografii cieczowej z detekcja tandemowa spektrometria mas (LC/MS/MS) PN-EN 15662","categories":["food"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Pesticide residue","search_en":"Food of plant origin, agricultural products E Pesticide residue Liquid chromatography with tandem mass spectrometry detection (LC/MS/MS) PN-EN 15662","technique_en":"Liquid chromatography with tandem mass spectrometry detection (LC/MS/MS)","test_object_en":"Food of plant origin, agricultural products E","methodology_zh":"农药残留","search_zh":"植物源食品、农产品 E 农药残留 液相色谱-串联质谱检测法（LC/MS/MS） PN-EN 15662","technique_zh":"液相色谱-串联质谱检测法（LC/MS/MS）","test_object_zh":"植物源食品、农产品 E"},{"_id":"6a837436af14b9c0e7b1f361","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA)","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"PB/L-61","norm_bases":["PB/L-61"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":"E- Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.\nLista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniona publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) PB/L-61 Zywnosc E Zawartosc wielopierscieniowych weglowodorow aromatycznych (WWA)\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) PB/L-61","categories":["food"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Polycyclic aromatic hydrocarbons (PAH) content","search_en":"Food E Polycyclic aromatic hydrocarbons (PAH) content High-performance liquid chromatography with fluorescence detection (HPLC-FLD) PB/L-61","technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD)","test_object_en":"Food E","search_zh":"食品 E 多环芳烃（PAHs）含量 高效液相色谱-荧光检测法（HPLC-FLD） PB/L-61","technique_zh":"高效液相色谱-荧光检测法（HPLC-FLD）","test_object_zh":"食品 E","methodology_zh":"多环芳烃（PAHs）含量"},{"_id":"6a837436af14b9c0e7b1f362","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Żywność pochodzenia roślinnego E","methodology":"Pozostałość pestycydów","parameters":[],"technique":"Metoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC/MS/MS)","techniques":["Metoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC/MS/MS)"],"computed":[],"activity":"Pozostałość pestycydów\nMetoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC/MS/MS)","reference":"EURL-SRM QuPPe-PO-Method","norm_bases":["EURL-SRM QuPPe-PO-Method"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":"E- Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.\nLista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniona publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność pochodzenia roślinnego E Pozostałość pestycydów\nMetoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC/MS/MS) EURL-SRM QuPPe-PO-Method Zywnosc pochodzenia roslinnego E Pozostalosc pestycydow\nMetoda chromatografii cieczowej z detekcja tandemowa spektrometria mas (LC/MS/MS) EURL-SRM QuPPe-PO-Method","categories":["food"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Pesticide residue","search_en":"Food of plant origin E Pesticide residue Liquid chromatography with tandem mass spectrometry detection (LC/MS/MS) EURL-SRM QuPPe-PO-Method","technique_en":"Liquid chromatography with tandem mass spectrometry detection (LC/MS/MS)","test_object_en":"Food of plant origin E","methodology_zh":"农药残留","search_zh":"植物源食品 E 农药残留 液相色谱-串联质谱检测法（LC/MS/MS） EURL-SRM QuPPe-PO-Method","technique_zh":"液相色谱-串联质谱检测法（LC/MS/MS）","test_object_zh":"植物源食品 E"},{"_id":"6a837436af14b9c0e7b1f363","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Napoje spirytusowe","methodology":"Zawartość metanolu","parameters":[{"name":"Zakres","range":"(2,0 – 2000) g/hl alkoholu 100%"},{"name":"objętości"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC/FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC/FID)"],"computed":[],"activity":"Zawartość metanolu\nZakres:\nZakres (2,0 – 2000) g/hl alkoholu 100%\nobjętości\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC/FID)","reference":"PN-A 79529-7:2005","norm_bases":["PN-A 79529-7:2005"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Napoje spirytusowe Zawartość metanolu\nZakres:\nZakres (2,0 – 2000) g/hl alkoholu 100%\nobjętości\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC/FID) PN-A 79529-7:2005 Napoje spirytusowe Zawartosc metanolu\nZakres:\nZakres (2,0 – 2000) g/hl alkoholu 100%\nobjetosci\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC/FID) PN-A 79529-7:2005","categories":["food"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Methanol content","parameters_en":[{"name":"Range","range":"(2,0 – 2000) g/hl alkoholu 100%"},{"name":"volume"}],"search_en":"Spirit drinks Methanol content Gas chromatography with flame ionization detection (GC/FID) Range volume PN-A 79529-7:2005","technique_en":"Gas chromatography with flame ionization detection (GC/FID)","test_object_en":"Spirit drinks","parameters_zh":[{"name":"范围","range":"(2,0 – 2000) g/hl alkoholu 100%"},{"name":"objętości"}],"search_zh":"烈性酒 甲醇含量 范围 PN-A 79529-7:2005","test_object_zh":"烈性酒","methodology_zh":"甲醇含量"},{"_id":"6a837436af14b9c0e7b1f364","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Napoje spirytusowe","methodology":"Moc objętościowa alkoholu","parameters":[{"name":"Zakres","range":"(5,0 – 96,0)%"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC/FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC/FID)"],"computed":[],"activity":"Moc objętościowa alkoholu\nZakres (5,0 – 96,0)%\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC/FID)","reference":"PB/L-90 wyd. 1 z dnia 03.04.2014r.","norm_bases":["PB/L-90 wyd. 1 z dnia 03.04.2014r."],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Napoje spirytusowe Moc objętościowa alkoholu\nZakres (5,0 – 96,0)%\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC/FID) PB/L-90 wyd. 1 z dnia 03.04.2014r. Napoje spirytusowe Moc objetosciowa alkoholu\nZakres (5,0 – 96,0)%\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC/FID) PB/L-90 wyd. 1 z dnia 03.04.2014r.","categories":["food"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Alcoholic strength by volume","parameters_en":[{"name":"Range","range":"(5,0 – 96,0)%"}],"search_en":"Spirit drinks Alcoholic strength by volume Gas chromatography with flame ionization detection (GC/FID) Range PB/L-90 wyd. 1 z dnia 03.04.2014r.","technique_en":"Gas chromatography with flame ionization detection (GC/FID)","test_object_en":"Spirit drinks","parameters_zh":[{"name":"范围","range":"(5,0 – 96,0)%"}],"search_zh":"烈性酒 范围 PB/L-90 wyd. 1 z dnia 03.04.2014r.","test_object_zh":"烈性酒"},{"_id":"6a837436af14b9c0e7b1f365","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Napoje bezalkoholowe, Suplementy diety","methodology":"Zawartość kofeiny","parameters":[{"name":"Zakres","range":"(10 – 1000) mg/l"},{"name":"Zakres","range":"(1 – 500) mg/porcję"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją UV-Vis (HPLC/PDA)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją UV-Vis (HPLC/PDA)"],"computed":[],"activity":"Zawartość kofeiny\nZakres:\nZakres (10 – 1000) mg/l\nZakres (1 – 500) mg/porcję\nMetoda wysokosprawnej chromatografii cieczowej z detekcją UV-Vis (HPLC/PDA)","reference":"PB/L-92 wyd. 3 z dnia 28.02.2022r.","norm_bases":["PB/L-92 wyd. 3 z dnia 28.02.2022r."],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Napoje bezalkoholowe, Suplementy diety Zawartość kofeiny\nZakres:\nZakres (10 – 1000) mg/l\nZakres (1 – 500) mg/porcję\nMetoda wysokosprawnej chromatografii cieczowej z detekcją UV-Vis (HPLC/PDA) PB/L-92 wyd. 3 z dnia 28.02.2022r. Napoje bezalkoholowe, Suplementy diety Zawartosc kofeiny\nZakres:\nZakres (10 – 1000) mg/l\nZakres (1 – 500) mg/porcje\nMetoda wysokosprawnej chromatografii cieczowej z detekcja UV-Vis (HPLC/PDA) PB/L-92 wyd. 3 z dnia 28.02.2022r.","categories":["food","pharma"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Caffeine content","parameters_en":[{"name":"Range","range":"(10 – 1000) mg/l"},{"name":"Range","range":"(1 – 500) mg/porcję"}],"search_en":"Non-alcoholic beverages, Food supplements Caffeine content High-performance liquid chromatography with UV-Vis detection (HPLC/PDA) Range Range PB/L-92 wyd. 3 z dnia 28.02.2022r.","technique_en":"High-performance liquid chromatography with UV-Vis detection (HPLC/PDA)","test_object_en":"Non-alcoholic beverages, Food supplements","parameters_zh":[{"name":"范围","range":"(10 – 1000) mg/l"},{"name":"范围","range":"(1 – 500) mg/porcję"}],"search_zh":"咖啡因含量 范围 范围 PB/L-92 wyd. 3 z dnia 28.02.2022r.","methodology_zh":"咖啡因含量"},{"_id":"6a837436af14b9c0e7b1f366","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Suplementy diety","methodology":"Zawartość diosminy","parameters":[{"name":"Zakres","range":"(10 – 600) mg/porcję"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją UV-Vis (HPLC/PDA)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją UV-Vis (HPLC/PDA)"],"computed":[],"activity":"Zawartość diosminy\nZakres (10 – 600) mg/porcję\nMetoda wysokosprawnej chromatografii cieczowej z detekcją UV-Vis (HPLC/PDA)","reference":"PB/L-101 wyd. 3 z dnia 28.02.2022r.","norm_bases":["PB/L-101 wyd. 3 z dnia 28.02.2022r."],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Suplementy diety Zawartość diosminy\nZakres (10 – 600) mg/porcję\nMetoda wysokosprawnej chromatografii cieczowej z detekcją UV-Vis (HPLC/PDA) PB/L-101 wyd. 3 z dnia 28.02.2022r. Suplementy diety Zawartosc diosminy\nZakres (10 – 600) mg/porcje\nMetoda wysokosprawnej chromatografii cieczowej z detekcja UV-Vis (HPLC/PDA) PB/L-101 wyd. 3 z dnia 28.02.2022r.","categories":["pharma"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Diosmin content","parameters_en":[{"name":"Range","range":"(10 – 600) mg/porcję"}],"search_en":"Food supplements Diosmin content High-performance liquid chromatography with UV-Vis detection (HPLC/PDA) Range PB/L-101 wyd. 3 z dnia 28.02.2022r.","technique_en":"High-performance liquid chromatography with UV-Vis detection (HPLC/PDA)","test_object_en":"Food supplements","parameters_zh":[{"name":"范围","range":"(10 – 600) mg/porcję"}],"search_zh":"膳食补充剂 范围 PB/L-101 wyd. 3 z dnia 28.02.2022r.","test_object_zh":"膳食补充剂"},{"_id":"6a837436af14b9c0e7b1f367","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Suplementy diety","methodology":"Zawartość rutyny","parameters":[{"name":"Zakres","range":"(0,5 – 600) mg/porcję"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją UV-Vis (HPLC/PDA)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją UV-Vis (HPLC/PDA)"],"computed":[],"activity":"Zawartość rutyny\nZakres (0,5 – 600) mg/porcję\nMetoda wysokosprawnej chromatografii cieczowej z detekcją UV-Vis (HPLC/PDA)","reference":"PB/L-102 wyd. 3 z dnia 28.02.2022r.","norm_bases":["PB/L-102 wyd. 3 z dnia 28.02.2022r."],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Suplementy diety Zawartość rutyny\nZakres (0,5 – 600) mg/porcję\nMetoda wysokosprawnej chromatografii cieczowej z detekcją UV-Vis (HPLC/PDA) PB/L-102 wyd. 3 z dnia 28.02.2022r. Suplementy diety Zawartosc rutyny\nZakres (0,5 – 600) mg/porcje\nMetoda wysokosprawnej chromatografii cieczowej z detekcja UV-Vis (HPLC/PDA) PB/L-102 wyd. 3 z dnia 28.02.2022r.","categories":["pharma"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Rutin content","parameters_en":[{"name":"Range","range":"(0,5 – 600) mg/porcję"}],"search_en":"Food supplements Rutin content High-performance liquid chromatography with UV-Vis detection (HPLC/PDA) Range PB/L-102 wyd. 3 z dnia 28.02.2022r.","technique_en":"High-performance liquid chromatography with UV-Vis detection (HPLC/PDA)","test_object_en":"Food supplements","parameters_zh":[{"name":"范围","range":"(0,5 – 600) mg/porcję"}],"search_zh":"膳食补充剂 范围 PB/L-102 wyd. 3 z dnia 28.02.2022r.","test_object_zh":"膳食补充剂"},{"_id":"6a837436af14b9c0e7b1f368","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w temp. 22°C w temp. 36°C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w temp. 22°C w temp. 36°C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Biologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w temp. 22°C w temp. 36°C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w temp. 22°C w temp. 36°C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total count of microorganisms at 22°C at 36°C","search_en":"Water intended for human consumption Total count of microorganisms at 22°C at 36°C Plate method (pour plate) PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"生活饮用水"},{"_id":"6a837436af14b9c0e7b1f369","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba enterokoków kałowych.","parameters":[],"technique":"Metoda filtracji membranowej;","techniques":["Metoda filtracji membranowej;"],"computed":[],"activity":"Liczba enterokoków kałowych.\nMetoda filtracji membranowej;","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Biologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba enterokoków kałowych.\nMetoda filtracji membranowej; PN-EN ISO 7899-2:2004 Woda do spozycia przez ludzi Liczba enterokokow kalowych.\nMetoda filtracji membranowej; PN-EN ISO 7899-2:2004","categories":["water"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Intestinal enterococci count.","search_en":"Water intended for human consumption Intestinal enterococci count. Membrane filtration method; PN-EN ISO 7899-2:2004","technique_en":"Membrane filtration method;","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 PN-EN ISO 7899-2:2004","test_object_zh":"生活饮用水"},{"_id":"6a837436af14b9c0e7b1f36a","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba bakterii Pseudomonas aeruginosa.","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii Pseudomonas aeruginosa.\nMetoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Biologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba bakterii Pseudomonas aeruginosa.\nMetoda filtracji membranowej PN-EN ISO 16266:2009 Woda do spozycia przez ludzi Liczba bakterii Pseudomonas aeruginosa.\nMetoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water","microbiology"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Pseudomonas aeruginosa count.","search_en":"Water intended for human consumption Pseudomonas aeruginosa count. Membrane filtration method PN-EN ISO 16266:2009","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 膜过滤法 PN-EN ISO 16266:2009","technique_zh":"膜过滤法","test_object_zh":"生活饮用水"},{"_id":"6a837436af14b9c0e7b1f36b","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba przetrwalników beztlenowców redukujących siarczyny (Clostridia).","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba przetrwalników beztlenowców redukujących siarczyny (Clostridia).\nMetoda filtracji membranowej","reference":"PN-EN 26461-2:2001","norm_bases":["PN-EN 26461-2:2001"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Biologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba przetrwalników beztlenowców redukujących siarczyny (Clostridia).\nMetoda filtracji membranowej PN-EN 26461-2:2001 Woda do spozycia przez ludzi Liczba przetrwalnikow beztlenowcow redukujacych siarczyny (Clostridia).\nMetoda filtracji membranowej PN-EN 26461-2:2001","categories":["water"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Count of spores of sulphite-reducing anaerobes (Clostridia).","search_en":"Water intended for human consumption Count of spores of sulphite-reducing anaerobes (Clostridia). Membrane filtration method PN-EN 26461-2:2001","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 膜过滤法 PN-EN 26461-2:2001","technique_zh":"膜过滤法","test_object_zh":"生活饮用水"},{"_id":"6a837436af14b9c0e7b1f36c","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba Clostridium perfringens łącznie ze sporami","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Clostridium perfringens łącznie ze sporami\nMetoda filtracji membranowej","reference":"PN-EN ISO 14189:2016-10","norm_bases":["PN-EN ISO 14189:2016-10"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Biologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba Clostridium perfringens łącznie ze sporami\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10 Woda do spozycia przez ludzi Liczba Clostridium perfringens lacznie ze sporami\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10","categories":["water"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Clostridium perfringens count including spores","search_en":"Water intended for human consumption Clostridium perfringens count including spores Membrane filtration method PN-EN ISO 14189:2016-10","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 产气荚膜梭菌数（含芽孢） 膜过滤法 PN-EN ISO 14189:2016-10","technique_zh":"膜过滤法","test_object_zh":"生活饮用水","methodology_zh":"产气荚膜梭菌数（含芽孢）"},{"_id":"6a837436af14b9c0e7b1f36d","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba bakterii z grupy coli.","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii z grupy coli.\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014/A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12","PN-EN ISO 9308-1:2014/A1:2017-04"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Biologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba bakterii z grupy coli.\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014/A1:2017-04 Woda do spozycia przez ludzi Liczba bakterii z grupy coli.\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014/A1:2017-04","categories":["water","microbiology"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Coliform bacteria count.","search_en":"Water intended for human consumption Coliform bacteria count. Membrane filtration method PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014/A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 膜过滤法 PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014/A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"生活饮用水"},{"_id":"6a837436af14b9c0e7b1f36e","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba Escherichia coli.","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Escherichia coli.\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014/A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12","PN-EN ISO 9308-1:2014/A1:2017-04"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Biologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba Escherichia coli.\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014/A1:2017-04 Woda do spozycia przez ludzi Liczba Escherichia coli.\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014/A1:2017-04","categories":["water","microbiology"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Escherichia coli count.","search_en":"Water intended for human consumption Escherichia coli count. Membrane filtration method PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014/A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 膜过滤法 PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014/A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"生活饮用水"},{"_id":"6a837436af14b9c0e7b1f36f","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda ciepła użytkowa","methodology":"Liczba bakterii z rodzaju Legionella, Matryca A: Procedura 5 (pożywka A - BCYE);, Procedura 7 (pożywka C -GVPC);","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii z rodzaju Legionella, Matryca A: Procedura 5 (pożywka A - BCYE);, Procedura 7 (pożywka C -GVPC);\nMetoda filtracji membranowej","reference":"PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08/Ap1:2019-12","norm_bases":["PN-EN ISO 11731:2017-08","PN-EN ISO 11731:2017-08/Ap1:2019-12"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Biologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda ciepła użytkowa Liczba bakterii z rodzaju Legionella, Matryca A: Procedura 5 (pożywka A - BCYE);, Procedura 7 (pożywka C -GVPC);\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08/Ap1:2019-12 Woda ciepla uzytkowa Liczba bakterii z rodzaju Legionella, Matryca A: Procedura 5 (pozywka A - BCYE);, Procedura 7 (pozywka C -GVPC);\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08/Ap1:2019-12","categories":["microbiology","water"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Count of bacteria of the genus Legionella, Matrix A: Procedure 5 (medium A - BCYE);, Procedure 7 (medium C -GVPC);","search_en":"Domestic hot water Count of bacteria of the genus Legionella, Matrix A: Procedure 5 (medium A - BCYE);, Procedure 7 (medium C -GVPC); Membrane filtration method PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08/Ap1:2019-12","technique_en":"Membrane filtration method","test_object_en":"Domestic hot water","search_zh":"生活热水 膜过滤法 PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08/Ap1:2019-12","technique_zh":"膜过滤法","test_object_zh":"生活热水"},{"_id":"6a837436af14b9c0e7b1f370","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda ciepła użytkowa","methodology":"Pobieranie próbek do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007","norm_bases":["PN-EN ISO 19458:2007"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Biologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda ciepła użytkowa Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 Woda do spozycia przez ludzi, Woda ciepla uzytkowa Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007","categories":["water","microbiology"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for microbiological testing","search_en":"Water intended for human consumption, Domestic hot water Sampling for microbiological testing PN-EN ISO 19458:2007","test_object_en":"Water intended for human consumption, Domestic hot water","methodology_zh":"微生物检测用样品采集","search_zh":"微生物检测用样品采集 PN-EN ISO 19458:2007"},{"_id":"6a837436af14b9c0e7b1f371","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-5:2017-10","norm_bases":["PN-ISO 5667-5:2017-10"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-5:2017-10 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-5:2017-10","categories":["water"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Water intended for human consumption Sampling for chemical and physical testing PN-ISO 5667-5:2017-10","test_object_en":"Water intended for human consumption","methodology_zh":"化学与物理检测用样品采集","search_zh":"生活饮用水 化学与物理检测用样品采集 PN-ISO 5667-5:2017-10","test_object_zh":"生活饮用水"},{"_id":"6a837436af14b9c0e7b1f372","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Przewodność elektryczna właściwa w 25oC","parameters":[{"name":"Zakres","range":"(100 – 3000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa w 25oC\nZakres (100 – 3000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Przewodność elektryczna właściwa w 25oC\nZakres (100 – 3000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa w 25oC\nZakres (100 – 3000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity at 25oC","parameters_en":[{"name":"Range","range":"(100 – 3000) μS/cm"}],"search_en":"Water intended for human consumption Electrical conductivity at 25oC Conductometric method Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(100 – 3000) μS/cm"}],"search_zh":"生活饮用水 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"生活饮用水"},{"_id":"6a837436af14b9c0e7b1f373","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie rozpuszczonych jonów","parameters":[{"name":"Fluorki","range":"(0,05 – 2,0) mg/l"},{"name":"Chlorki","range":"(0,05 – 250) mg/l"},{"name":"Azotyny","range":"(0,05 – 5,0) mg/l"},{"name":"Azotany","range":"(0,05 – 100) mg/l"},{"name":"Siarczany","range":"(0,05 – 250) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie rozpuszczonych jonów\nZakres:\nFluorki (0,05 – 2,0) mg/l\nChlorki (0,05 – 250) mg/l\nAzotyny (0,05 – 5,0) mg/l\nAzotany (0,05 – 100) mg/l\nSiarczany (0,05 – 250) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie rozpuszczonych jonów\nZakres:\nFluorki (0,05 – 2,0) mg/l\nChlorki (0,05 – 250) mg/l\nAzotyny (0,05 – 5,0) mg/l\nAzotany (0,05 – 100) mg/l\nSiarczany (0,05 – 250) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Woda do spozycia przez ludzi Stezenie rozpuszczonych jonow\nZakres:\nFluorki (0,05 – 2,0) mg/l\nChlorki (0,05 – 250) mg/l\nAzotyny (0,05 – 5,0) mg/l\nAzotany (0,05 – 100) mg/l\nSiarczany (0,05 – 250) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissolved ion concentration","parameters_en":[{"name":"Fluorides","range":"(0,05 – 2,0) mg/l"},{"name":"Chlorides","range":"(0,05 – 250) mg/l"},{"name":"Nitrites","range":"(0,05 – 5,0) mg/l"},{"name":"Nitrates","range":"(0,05 – 100) mg/l"},{"name":"Sulfates","range":"(0,05 – 250) mg/l"}],"search_en":"Water intended for human consumption Dissolved ion concentration Ion chromatography with conductometric detection (IC-CD) Fluorides Chlorides Nitrites Nitrates Sulfates PN-EN ISO 10304-1:2009+AC:2012","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"氟化物","range":"(0,05 – 2,0) mg/l"},{"name":"氯化物","range":"(0,05 – 250) mg/l"},{"name":"亚硝酸盐","range":"(0,05 – 5,0) mg/l"},{"name":"硝酸盐","range":"(0,05 – 100) mg/l"},{"name":"硫酸盐","range":"(0,05 – 250) mg/l"}],"search_zh":"生活饮用水 溶解性离子浓度 离子色谱-电导检测法（IC-CD） 氟化物 氯化物 亚硝酸盐 硝酸盐 硫酸盐 PN-EN ISO 10304-1:2009+AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"生活饮用水","methodology_zh":"溶解性离子浓度"},{"_id":"6a837436af14b9c0e7b1f374","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,025 – 2,5) mg/l"}],"technique":"Metoda spektrometryczna","techniques":["Metoda spektrometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,025 – 2,5) mg/l\nMetoda spektrometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie azotu amonowego\nZakres (0,025 – 2,5) mg/l\nMetoda spektrometryczna PN-ISO 7150-1:2002 Woda do spozycia przez ludzi Stezenie azotu amonowego\nZakres (0,025 – 2,5) mg/l\nMetoda spektrometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,025 – 2,5) mg/l"}],"search_en":"Water intended for human consumption Ammonium nitrogen concentration Spectrometric method Range PN-ISO 7150-1:2002","technique_en":"Spectrometric method","test_object_en":"Water intended for human consumption","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,025 – 2,5) mg/l"}],"search_zh":"生活饮用水 氨氮浓度 光谱法 范围 PN-ISO 7150-1:2002","test_object_zh":"生活饮用水","technique_zh":"光谱法"},{"_id":"6a837436af14b9c0e7b1f375","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi pH\nZakres 2,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda do spozycia przez ludzi pH\nZakres 2,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 – 10,0"}],"search_en":"Water intended for human consumption pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water intended for human consumption","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 10,0"}],"search_zh":"生活饮用水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"生活饮用水"},{"_id":"6a837436af14b9c0e7b1f376","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,20 – 100) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,20 – 100) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016","norm_bases":["PN-EN ISO 7027-1:2016"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Mętność\nZakres (0,20 – 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016 Woda do spozycia przez ludzi Metnosc\nZakres (0,20 – 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016","categories":["water"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,20 – 100) NTU"}],"search_en":"Water intended for human consumption Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016","technique_en":"Nephelometric method","test_object_en":"Water intended for human consumption","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,20 – 100) NTU"}],"search_zh":"生活饮用水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016","technique_zh":"浊度法（散射法）","test_object_zh":"生活饮用水"},{"_id":"6a837436af14b9c0e7b1f377","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(2 – 60) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Barwa\nZakres (2 – 60) mg/l Pt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012+Ap1:2015-06 Metoda C","norm_bases":["PN-EN ISO 7887:2012+Ap1:2015-06 Metoda C"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Barwa\nZakres (2 – 60) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012+Ap1:2015-06 Metoda C Woda do spozycia przez ludzi Barwa\nZakres (2 – 60) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012+Ap1:2015-06 Metoda C","categories":["water"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"(2 – 60) mg/l Pt"}],"search_en":"Water intended for human consumption Colour Spectrophotometric method Range PN-EN ISO 7887:2012+Ap1:2015-06 Metoda C","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(2 – 60) mg/l Pt"}],"search_zh":"生活饮用水 色度 分光光度法 范围 PN-EN ISO 7887:2012+Ap1:2015-06 Metoda C","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a837436af14b9c0e7b1f378","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie chloru wolnego","parameters":[{"name":"Zakres","range":"(0,05 – 5,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chloru wolnego\nZakres (0,05 – 5,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7393-2:2018-04","norm_bases":["PN-EN ISO 7393-2:2018-04"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie chloru wolnego\nZakres (0,05 – 5,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 7393-2:2018-04 Woda do spozycia przez ludzi Stezenie chloru wolnego\nZakres (0,05 – 5,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 7393-2:2018-04","categories":["water"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free chlorine concentration","parameters_en":[{"name":"Range","range":"(0,05 – 5,0) mg/l"}],"search_en":"Water intended for human consumption Free chlorine concentration Spectrophotometric method Range PN-EN ISO 7393-2:2018-04","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","methodology_zh":"游离氯浓度","parameters_zh":[{"name":"范围","range":"(0,05 – 5,0) mg/l"}],"search_zh":"生活饮用水 游离氯浓度 分光光度法 范围 PN-EN ISO 7393-2:2018-04","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a837436af14b9c0e7b1f379","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie chloranów, chlorynów","parameters":[{"name":"Chlorany","range":"(0,10 – 1,0) mg/l"},{"name":"Chloryny","range":"(0,10 – 1,0) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie chloranów, chlorynów\nZakres:\nChlorany (0,10 – 1,0) mg/l\nChloryny (0,10 – 1,0) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-4:2022-08","norm_bases":["PN-EN ISO 10304-4:2022-08"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie chloranów, chlorynów\nZakres:\nChlorany (0,10 – 1,0) mg/l\nChloryny (0,10 – 1,0) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-4:2022-08 Woda do spozycia przez ludzi Stezenie chloranow, chlorynow\nZakres:\nChlorany (0,10 – 1,0) mg/l\nChloryny (0,10 – 1,0) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-4:2022-08","categories":["water"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chlorate, chlorite concentration","parameters_en":[{"name":"Chlorates","range":"(0,10 – 1,0) mg/l"},{"name":"Chlorites","range":"(0,10 – 1,0) mg/l"}],"search_en":"Water intended for human consumption Chlorate, chlorite concentration Ion chromatography with conductometric detection (IC-CD) Chlorates Chlorites PN-EN ISO 10304-4:2022-08","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 氯酸盐、亚氯酸盐浓度 离子色谱-电导检测法（IC-CD） 氯酸盐 亚氯酸盐 PN-EN ISO 10304-4:2022-08","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"生活饮用水","parameters_zh":[{"name":"氯酸盐","range":"(0,10 – 1,0) mg/l"},{"name":"亚氯酸盐","range":"(0,10 – 1,0) mg/l"}],"methodology_zh":"氯酸盐、亚氯酸盐浓度"},{"_id":"6a837436af14b9c0e7b1f37a","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Suma chloranów i chlorynów (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma chloranów i chlorynów (z obliczeń)","reference":"PN-EN ISO 10304-4:2022-08","norm_bases":["PN-EN ISO 10304-4:2022-08"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Suma chloranów i chlorynów (z obliczeń) PN-EN ISO 10304-4:2022-08 Woda do spozycia przez ludzi Suma chloranow i chlorynow (z obliczen) PN-EN ISO 10304-4:2022-08","categories":["water"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of chlorates and chlorites (calculated)","search_en":"Water intended for human consumption Sum of chlorates and chlorites (calculated) PN-EN ISO 10304-4:2022-08","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 氯酸盐与亚氯酸盐总量（由计算得出） PN-EN ISO 10304-4:2022-08","test_object_zh":"生活饮用水","methodology_zh":"氯酸盐与亚氯酸盐总量（由计算得出）"},{"_id":"6a837436af14b9c0e7b1f37b","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie kationów","parameters":[{"name":"Magnez","range":"(1 – 125) mg/l"},{"name":"Sód","range":"(1 – 200) mg/l"},{"name":"Wapń","range":"(2 – 200) mg/l"},{"name":"Jon amonowy","range":"(0,1 – 2,5) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie kationów\nZakres:\nMagnez (1 – 125) mg/l\nSód (1 – 200) mg/l\nWapń (2 – 200) mg/l\nJon amonowy (0,1 – 2,5) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 14911:2002","norm_bases":["PN-EN ISO 14911:2002"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie kationów\nZakres:\nMagnez (1 – 125) mg/l\nSód (1 – 200) mg/l\nWapń (2 – 200) mg/l\nJon amonowy (0,1 – 2,5) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 14911:2002 Woda do spozycia przez ludzi Stezenie kationow\nZakres:\nMagnez (1 – 125) mg/l\nSod (1 – 200) mg/l\nWapn (2 – 200) mg/l\nJon amonowy (0,1 – 2,5) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 14911:2002","categories":["water"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Cation concentrations","parameters_en":[{"name":"Magnesium","range":"(1 – 125) mg/l"},{"name":"Sodium","range":"(1 – 200) mg/l"},{"name":"Calcium","range":"(2 – 200) mg/l"},{"name":"Ammonium ion","range":"(0,1 – 2,5) mg/l"}],"search_en":"Water intended for human consumption Cation concentrations Ion chromatography with conductometric detection (IC-CD) Magnesium Sodium Calcium Ammonium ion PN-EN ISO 14911:2002","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 阳离子浓度 离子色谱-电导检测法（IC-CD） 镁 钠 钙 PN-EN ISO 14911:2002","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"生活饮用水","parameters_zh":[{"name":"镁","range":"(1 – 125) mg/l"},{"name":"钠","range":"(1 – 200) mg/l"},{"name":"钙","range":"(2 – 200) mg/l"},{"name":"Jon amonowy","range":"(0,1 – 2,5) mg/l"}],"methodology_zh":"阳离子浓度"},{"_id":"6a837436af14b9c0e7b1f37c","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Sumaryczna zawartość wapnia i magnezu – twardość ogólna (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Sumaryczna zawartość wapnia i magnezu – twardość ogólna (z obliczeń)","reference":"PN-EN ISO 14911:2002","norm_bases":["PN-EN ISO 14911:2002"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Sumaryczna zawartość wapnia i magnezu – twardość ogólna (z obliczeń) PN-EN ISO 14911:2002 Woda do spozycia przez ludzi Sumaryczna zawartosc wapnia i magnezu – twardosc ogolna (z obliczen) PN-EN ISO 14911:2002","categories":["water"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total calcium and magnesium content – total hardness (calculated)","search_en":"Water intended for human consumption Total calcium and magnesium content – total hardness (calculated) PN-EN ISO 14911:2002","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 PN-EN ISO 14911:2002","test_object_zh":"生活饮用水"},{"_id":"6a837436af14b9c0e7b1f37d","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie cyjanków ogólnych","parameters":[{"name":"Zakres","range":"(5,0 – 100) μg/l"}],"technique":"Metoda analizy przepływowej ciągłej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda analizy przepływowej ciągłej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie cyjanków ogólnych\nZakres (5,0 – 100) μg/l\nMetoda analizy przepływowej ciągłej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 14403-2:2012","norm_bases":["PN-EN ISO 14403-2:2012"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie cyjanków ogólnych\nZakres (5,0 – 100) μg/l\nMetoda analizy przepływowej ciągłej (CFA) z detekcją spektrofotometryczną PN-EN ISO 14403-2:2012 Woda do spozycia przez ludzi Stezenie cyjankow ogolnych\nZakres (5,0 – 100) μg/l\nMetoda analizy przeplywowej ciaglej (CFA) z detekcja spektrofotometryczna PN-EN ISO 14403-2:2012","categories":["water"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total cyanide concentration","parameters_en":[{"name":"Range","range":"(5,0 – 100) μg/l"}],"search_en":"Water intended for human consumption Total cyanide concentration Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN ISO 14403-2:2012","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(5,0 – 100) μg/l"}],"search_zh":"生活饮用水 总氰化物浓度 范围 PN-EN ISO 14403-2:2012","test_object_zh":"生活饮用水","methodology_zh":"总氰化物浓度"},{"_id":"6a837436af14b9c0e7b1f37e","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Wartość indeksu nadmanganianowego","parameters":[{"name":"Zakres","range":"(0,50 – 10) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Wartość indeksu nadmanganianowego\nZakres (0,50 – 10) mg/l O2\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Wartość indeksu nadmanganianowego\nZakres (0,50 – 10) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda do spozycia przez ludzi Wartosc indeksu nadmanganianowego\nZakres (0,50 – 10) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Permanganate index value","parameters_en":[{"name":"Range","range":"(0,50 – 10) mg/l O2"}],"search_en":"Water intended for human consumption Permanganate index value Titrimetric method Range PN-EN ISO 8467:2001","technique_en":"Titrimetric method","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,50 – 10) mg/l O2"}],"search_zh":"生活饮用水 滴定法 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"生活饮用水"},{"_id":"6a837436af14b9c0e7b1f37f","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie związków organicznych","parameters":[{"name":"Benzen","range":"(0,2 – 20) μg/l"},{"name":"Zakres","range":"1,2-dichloroetan (0,2 – 20) μg/l"},{"name":"Trichloroeten","range":"(0,2 – 20) μg/l"},{"name":"Tetrachloroeten","range":"(0,2 – 20) μg/l"}],"technique":"Metoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją spektrometrią mas (P&T GC-MS)","techniques":["Metoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją spektrometrią mas (P&T GC-MS)"],"computed":[],"activity":"Stężenie związków organicznych\nZakres:\nBenzen (0,2 – 20) μg/l\nZakres 1,2-dichloroetan (0,2 – 20) μg/l\nTrichloroeten (0,2 – 20) μg/l\nTetrachloroeten (0,2 – 20) μg/l\nMetoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją spektrometrią mas (P&T GC-MS)","reference":"PN-EN ISO 15680:2008","norm_bases":["PN-EN ISO 15680:2008"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie związków organicznych\nZakres:\nBenzen (0,2 – 20) μg/l\nZakres 1,2-dichloroetan (0,2 – 20) μg/l\nTrichloroeten (0,2 – 20) μg/l\nTetrachloroeten (0,2 – 20) μg/l\nMetoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją spektrometrią mas (P&T GC-MS) PN-EN ISO 15680:2008 Woda do spozycia przez ludzi Stezenie zwiazkow organicznych\nZakres:\nBenzen (0,2 – 20) μg/l\nZakres 1,2-dichloroetan (0,2 – 20) μg/l\nTrichloroeten (0,2 – 20) μg/l\nTetrachloroeten (0,2 – 20) μg/l\nMetoda chromatografii gazowej z technika wylapywania i wyplukiwania (Purge&Trap) i detekcja spektrometria mas (P&T GC-MS) PN-EN ISO 15680:2008","categories":["water"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of organic compounds","parameters_en":[{"name":"Benzene","range":"(0,2 – 20) μg/l"},{"name":"Range","range":"1,2-dichloroetan (0,2 – 20) μg/l"},{"name":"Trichloroethene","range":"(0,2 – 20) μg/l"},{"name":"Tetrachloroethene","range":"(0,2 – 20) μg/l"}],"search_en":"Water intended for human consumption Concentration of organic compounds Gas chromatography with purge and trap technique (Purge&Trap) and mass spectrometry detection (P&T GC-MS) Benzene Range Trichloroethene Tetrachloroethene PN-EN ISO 15680:2008","technique_en":"Gas chromatography with purge and trap technique (Purge&Trap) and mass spectrometry detection (P&T GC-MS)","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"苯","range":"(0,2 – 20) μg/l"},{"name":"范围","range":"1,2-dichloroetan (0,2 – 20) μg/l"},{"name":"三氯乙烯","range":"(0,2 – 20) μg/l"},{"name":"四氯乙烯","range":"(0,2 – 20) μg/l"}],"search_zh":"生活饮用水 有机化合物浓度 吹扫捕集气相色谱-质谱法（P&T GC-MS） 苯 范围 三氯乙烯 四氯乙烯 PN-EN ISO 15680:2008","test_object_zh":"生活饮用水","methodology_zh":"有机化合物浓度","technique_zh":"吹扫捕集气相色谱-质谱法（P&T GC-MS）"},{"_id":"6a837436af14b9c0e7b1f380","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Suma trichloroetenu i tetrachloroetenu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma trichloroetenu i tetrachloroetenu (z obliczeń)","reference":"PN-EN ISO 15680:2008","norm_bases":["PN-EN ISO 15680:2008"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Suma trichloroetenu i tetrachloroetenu (z obliczeń) PN-EN ISO 15680:2008 Woda do spozycia przez ludzi Suma trichloroetenu i tetrachloroetenu (z obliczen) PN-EN ISO 15680:2008","categories":["water"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of trichloroethene and tetrachloroethene (calculated)","search_en":"Water intended for human consumption Sum of trichloroethene and tetrachloroethene (calculated) PN-EN ISO 15680:2008","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 三氯乙烯与四氯乙烯总量（由计算得出） PN-EN ISO 15680:2008","test_object_zh":"生活饮用水","methodology_zh":"三氯乙烯与四氯乙烯总量（由计算得出）"},{"_id":"6a837436af14b9c0e7b1f381","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda na pływalniach","methodology":"Stężenie trihalometanów (THM)","parameters":[{"name":"Trichlorometan (chloroform)","range":"(2,0 – 300) μg/l"},{"name":"Bromodichlorometan","range":"(2,0 – 150) μg/l"},{"name":"Dibromochlorometan","range":"(2,0 – 150) μg/l"},{"name":"Tribromometan (bromoform)","range":"(2,0 – 150) μg/l"}],"technique":"Metoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją spektrometrią mas (P&T GC-MS)","techniques":["Metoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją spektrometrią mas (P&T GC-MS)"],"computed":[],"activity":"Stężenie trihalometanów (THM)\nZakres:\nTrichlorometan (chloroform) (2,0 – 300) μg/l\nBromodichlorometan (2,0 – 150) μg/l\nDibromochlorometan (2,0 – 150) μg/l\nTribromometan (bromoform) (2,0 – 150) μg/l\nMetoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją spektrometrią mas (P&T GC-MS)","reference":"PN-EN ISO 15680:2008","norm_bases":["PN-EN ISO 15680:2008"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda na pływalniach Stężenie trihalometanów (THM)\nZakres:\nTrichlorometan (chloroform) (2,0 – 300) μg/l\nBromodichlorometan (2,0 – 150) μg/l\nDibromochlorometan (2,0 – 150) μg/l\nTribromometan (bromoform) (2,0 – 150) μg/l\nMetoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją spektrometrią mas (P&T GC-MS) PN-EN ISO 15680:2008 Woda do spozycia przez ludzi, Woda na plywalniach Stezenie trihalometanow (THM)\nZakres:\nTrichlorometan (chloroform) (2,0 – 300) μg/l\nBromodichlorometan (2,0 – 150) μg/l\nDibromochlorometan (2,0 – 150) μg/l\nTribromometan (bromoform) (2,0 – 150) μg/l\nMetoda chromatografii gazowej z technika wylapywania i wyplukiwania (Purge&Trap) i detekcja spektrometria mas (P&T GC-MS) PN-EN ISO 15680:2008","categories":["water"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Trihalomethanes (THM) concentration","parameters_en":[{"name":"Trichloromethane (chloroform)","range":"(2,0 – 300) μg/l"},{"name":"Bromodichloromethane","range":"(2,0 – 150) μg/l"},{"name":"Dibromochloromethane","range":"(2,0 – 150) μg/l"},{"name":"Tribromometan (bromoform)","range":"(2,0 – 150) μg/l"}],"search_en":"Water intended for human consumption, Swimming pool water Trihalomethanes (THM) concentration Gas chromatography with purge and trap technique (Purge&Trap) and mass spectrometry detection (P&T GC-MS) Trichloromethane (chloroform) Bromodichloromethane Dibromochloromethane PN-EN ISO 15680:2008","technique_en":"Gas chromatography with purge and trap technique (Purge&Trap) and mass spectrometry detection (P&T GC-MS)","test_object_en":"Water intended for human consumption, Swimming pool water","search_zh":"生活饮用水、游泳池水 三卤甲烷（THM）浓度 吹扫捕集气相色谱-质谱法（P&T GC-MS） 一溴二氯甲烷 二溴一氯甲烷 PN-EN ISO 15680:2008","test_object_zh":"生活饮用水、游泳池水","parameters_zh":[{"name":"Trichlorometan (chloroform)","range":"(2,0 – 300) μg/l"},{"name":"一溴二氯甲烷","range":"(2,0 – 150) μg/l"},{"name":"二溴一氯甲烷","range":"(2,0 – 150) μg/l"},{"name":"Tribromometan (bromoform)","range":"(2,0 – 150) μg/l"}],"technique_zh":"吹扫捕集气相色谱-质谱法（P&T GC-MS）","methodology_zh":"三卤甲烷（THM）浓度"},{"_id":"6a837436af14b9c0e7b1f382","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda na pływalniach","methodology":"Suma stężeń trihalometanów (THM) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma stężeń trihalometanów (THM) (z obliczeń)","reference":"PN-EN ISO 15680:2008","norm_bases":["PN-EN ISO 15680:2008"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda na pływalniach Suma stężeń trihalometanów (THM) (z obliczeń) PN-EN ISO 15680:2008 Woda do spozycia przez ludzi, Woda na plywalniach Suma stezen trihalometanow (THM) (z obliczen) PN-EN ISO 15680:2008","categories":["water"],"row_index":55,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of trihalomethane (THM) concentrations (calculated)","search_en":"Water intended for human consumption, Swimming pool water Sum of trihalomethane (THM) concentrations (calculated) PN-EN ISO 15680:2008","test_object_en":"Water intended for human consumption, Swimming pool water","search_zh":"生活饮用水、游泳池水 PN-EN ISO 15680:2008","test_object_zh":"生活饮用水、游泳池水"},{"_id":"6a837436af14b9c0e7b1f383","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)","parameters":[{"name":"Benzo(a)piren","range":"(0,0018 - 0,05) μg/l"},{"name":"Benzo(b)fluoranten","range":"(0,0014 - 0,05) μg/l"},{"name":"Benzo(k)fluoranten","range":"(0,0009 - 0,05) μg/l"},{"name":"Benzo(ghi)perylen","range":"(0,0028 - 0,05) μg/l"},{"name":"Indeno(1,2,3-cd)piren","range":"(0,0024 - 0,05) μg/l"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC – FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC – FLD)"],"computed":[],"activity":"Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)\nZakres:\nBenzo(a)piren (0,0018 - 0,05) μg/l\nBenzo(b)fluoranten (0,0014 - 0,05) μg/l\nBenzo(k)fluoranten (0,0009 - 0,05) μg/l\nBenzo(ghi)perylen (0,0028 - 0,05) μg/l\nIndeno(1,2,3-cd)piren (0,0024 - 0,05) μg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC – FLD)","reference":"PB/L-82 wydanie 1 z dnia 11.04.2012r.","norm_bases":["PB/L-82 wydanie 1 z dnia 11.04.2012r."],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Fizykochemicznych; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)\nZakres:\nBenzo(a)piren (0,0018 - 0,05) μg/l\nBenzo(b)fluoranten (0,0014 - 0,05) μg/l\nBenzo(k)fluoranten (0,0009 - 0,05) μg/l\nBenzo(ghi)perylen (0,0028 - 0,05) μg/l\nIndeno(1,2,3-cd)piren (0,0024 - 0,05) μg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC – FLD) PB/L-82 wydanie 1 z dnia 11.04.2012r. Woda do spozycia przez ludzi Stezenie wielopierscieniowych weglowodorow aromatycznych (WWA)\nZakres:\nBenzo(a)piren (0,0018 - 0,05) μg/l\nBenzo(b)fluoranten (0,0014 - 0,05) μg/l\nBenzo(k)fluoranten (0,0009 - 0,05) μg/l\nBenzo(ghi)perylen (0,0028 - 0,05) μg/l\nIndeno(1,2,3-cd)piren (0,0024 - 0,05) μg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC – FLD) PB/L-82 wydanie 1 z dnia 11.04.2012r.","categories":["water"],"row_index":56,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of polycyclic aromatic hydrocarbons (PAH)","parameters_en":[{"name":"Benzo(a)pyrene","range":"(0,0018 - 0,05) μg/l"},{"name":"Benzo(b)fluoranthene","range":"(0,0014 - 0,05) μg/l"},{"name":"Benzo(k)fluoranthene","range":"(0,0009 - 0,05) μg/l"},{"name":"Benzo(ghi)perylene","range":"(0,0028 - 0,05) μg/l"},{"name":"Indeno(1,2,3-cd)pyrene","range":"(0,0024 - 0,05) μg/l"}],"search_en":"Water intended for human consumption Concentration of polycyclic aromatic hydrocarbons (PAH) High-performance liquid chromatography with fluorescence detection (HPLC – FLD) Benzo(a)pyrene Benzo(b)fluoranthene Benzo(k)fluoranthene Benzo(ghi)perylene Indeno(1,2,3-cd)pyrene PB/L-82 wydanie 1 z dnia 11.04.2012r.","technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC – FLD)","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 多环芳烃（PAHs）浓度 高效液相色谱-荧光检测法（HPLC – FLD） 苯并(a)芘 苯并(b)荧蒽 苯并(k)荧蒽 苯并(ghi)苝 茚并(1,2,3-cd)芘 PB/L-82 wydanie 1 z dnia 11.04.2012r.","test_object_zh":"生活饮用水","methodology_zh":"多环芳烃（PAHs）浓度","parameters_zh":[{"name":"苯并(a)芘","range":"(0,0018 - 0,05) μg/l"},{"name":"苯并(b)荧蒽","range":"(0,0014 - 0,05) μg/l"},{"name":"苯并(k)荧蒽","range":"(0,0009 - 0,05) μg/l"},{"name":"苯并(ghi)苝","range":"(0,0028 - 0,05) μg/l"},{"name":"茚并(1,2,3-cd)芘","range":"(0,0024 - 0,05) μg/l"}],"technique_zh":"高效液相色谱-荧光检测法（HPLC – FLD）"},{"_id":"6a837436af14b9c0e7b1f384","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Suma stężeń: Benzo(b)fluorantenu, Benzo(k)fluorantenu, Benzo(ghi)perylenu, Indeno(1,2,3-cd)pirenu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma stężeń: Benzo(b)fluorantenu, Benzo(k)fluorantenu, Benzo(ghi)perylenu, Indeno(1,2,3-cd)pirenu (z obliczeń)","reference":"PB/L-82 wydanie 1 z dnia 11.04.2012r.","norm_bases":["PB/L-82 wydanie 1 z dnia 11.04.2012r."],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Fizykochemicznych; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Suma stężeń: Benzo(b)fluorantenu, Benzo(k)fluorantenu, Benzo(ghi)perylenu, Indeno(1,2,3-cd)pirenu (z obliczeń) PB/L-82 wydanie 1 z dnia 11.04.2012r. Woda do spozycia przez ludzi Suma stezen: Benzo(b)fluorantenu, Benzo(k)fluorantenu, Benzo(ghi)perylenu, Indeno(1,2,3-cd)pirenu (z obliczen) PB/L-82 wydanie 1 z dnia 11.04.2012r.","categories":["water"],"row_index":57,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of concentrations of: Benzo(b)fluoranthene, Benzo(k)fluoranthene, Benzo(ghi)perylene, Indeno(1,2,3-cd)pyrene (calculated)","search_en":"Water intended for human consumption Sum of concentrations of: Benzo(b)fluoranthene, Benzo(k)fluoranthene, Benzo(ghi)perylene, Indeno(1,2,3-cd)pyrene (calculated) PB/L-82 wydanie 1 z dnia 11.04.2012r.","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 PB/L-82 wydanie 1 z dnia 11.04.2012r.","test_object_zh":"生活饮用水"},{"_id":"6a837436af14b9c0e7b1f385","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie rtęci","parameters":[{"name":"Zakres","range":"(0,0005 – 0,01) mg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)"],"computed":[],"activity":"Stężenie rtęci\nZakres (0,0005 – 0,01) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"PB/L-01 wydanie 5 z dnia 16.07.2021 r.","norm_bases":["PB/L-01 wydanie 5 z dnia 16.07.2021 r."],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Fizykochemicznych; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie rtęci\nZakres (0,0005 – 0,01) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PB/L-01 wydanie 5 z dnia 16.07.2021 r. Woda do spozycia przez ludzi Stezenie rteci\nZakres (0,0005 – 0,01) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PB/L-01 wydanie 5 z dnia 16.07.2021 r.","categories":["water"],"row_index":58,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury concentration","parameters_en":[{"name":"Range","range":"(0,0005 – 0,01) mg/l"}],"search_en":"Water intended for human consumption Mercury concentration Cold vapour atomic absorption spectrometry (CVAAS) Range PB/L-01 wydanie 5 z dnia 16.07.2021 r.","technique_en":"Cold vapour atomic absorption spectrometry (CVAAS)","test_object_en":"Water intended for human consumption","methodology_zh":"汞浓度","parameters_zh":[{"name":"范围","range":"(0,0005 – 0,01) mg/l"}],"search_zh":"生活饮用水 汞浓度 冷蒸气原子吸收光谱法（CVAAS） 范围 PB/L-01 wydanie 5 z dnia 16.07.2021 r.","technique_zh":"冷蒸气原子吸收光谱法（CVAAS）","test_object_zh":"生活饮用水"},{"_id":"6a837436af14b9c0e7b1f386","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie metali","parameters":[{"name":"Bor","range":"(10,0-5000) μg/l"},{"name":"Glin","range":"(10,0-5000) μg/l"},{"name":"Chrom","range":"(1,0-100) μg/l"},{"name":"Mangan","range":"(10,0-10000) μg/l"},{"name":"Żelazo","range":"(10,0-25000) μg/l"},{"name":"Nikiel","range":"(1,0-100) μg/l"},{"name":"Miedź","range":"(10,0-5000) μg/l"},{"name":"Arsen","range":"(1,0-100) μg/l"},{"name":"Selen","range":"(1,0-100) μg/l"},{"name":"Kadm","range":"(1,0-100) μg/l"},{"name":"Antymon","range":"(1,0-100) μg/l"},{"name":"Ołów","range":"(1,0-100) μg/l"},{"name":"Uran","range":"(1,0-100) μg/l"},{"name":"Srebro","range":"(1,0-100) μg/l"}],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"computed":[],"activity":"Stężenie metali\nZakres:\nBor (10,0-5000) μg/l\nGlin (10,0-5000) μg/l\nChrom (1,0-100) μg/l\nMangan (10,0-10000) μg/l\nŻelazo (10,0-25000) μg/l\nNikiel (1,0-100) μg/l\nMiedź (10,0-5000) μg/l\nArsen (1,0-100) μg/l\nSelen (1,0-100) μg/l\nKadm (1,0-100) μg/l\nAntymon (1,0-100) μg/l\nOłów (1,0-100) μg/l\nUran (1,0-100) μg/l\nSrebro (1,0-100) μg/l\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"PN-EN ISO 17294-2:2024-04","norm_bases":["PN-EN ISO 17294-2:2024-04"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Fizykochemicznych; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie metali\nZakres:\nBor (10,0-5000) μg/l\nGlin (10,0-5000) μg/l\nChrom (1,0-100) μg/l\nMangan (10,0-10000) μg/l\nŻelazo (10,0-25000) μg/l\nNikiel (1,0-100) μg/l\nMiedź (10,0-5000) μg/l\nArsen (1,0-100) μg/l\nSelen (1,0-100) μg/l\nKadm (1,0-100) μg/l\nAntymon (1,0-100) μg/l\nOłów (1,0-100) μg/l\nUran (1,0-100) μg/l\nSrebro (1,0-100) μg/l\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) PN-EN ISO 17294-2:2024-04 Woda do spozycia przez ludzi Stezenie metali\nZakres:\nBor (10,0-5000) μg/l\nGlin (10,0-5000) μg/l\nChrom (1,0-100) μg/l\nMangan (10,0-10000) μg/l\nZelazo (10,0-25000) μg/l\nNikiel (1,0-100) μg/l\nMiedz (10,0-5000) μg/l\nArsen (1,0-100) μg/l\nSelen (1,0-100) μg/l\nKadm (1,0-100) μg/l\nAntymon (1,0-100) μg/l\nOlow (1,0-100) μg/l\nUran (1,0-100) μg/l\nSrebro (1,0-100) μg/l\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) PN-EN ISO 17294-2:2024-04","categories":["materials","water"],"row_index":59,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Metal concentrations","parameters_en":[{"name":"Boron","range":"(10,0-5000) μg/l"},{"name":"Aluminium","range":"(10,0-5000) μg/l"},{"name":"Chromium","range":"(1,0-100) μg/l"},{"name":"Manganese","range":"(10,0-10000) μg/l"},{"name":"Iron","range":"(10,0-25000) μg/l"},{"name":"Nickel","range":"(1,0-100) μg/l"},{"name":"Copper","range":"(10,0-5000) μg/l"},{"name":"Arsenic","range":"(1,0-100) μg/l"},{"name":"Selenium","range":"(1,0-100) μg/l"},{"name":"Cadmium","range":"(1,0-100) μg/l"},{"name":"Antimony","range":"(1,0-100) μg/l"},{"name":"Lead","range":"(1,0-100) μg/l"},{"name":"Uranium","range":"(1,0-100) μg/l"},{"name":"Silver","range":"(1,0-100) μg/l"}],"search_en":"Water intended for human consumption Metal concentrations Inductively coupled plasma mass spectrometry (ICP-MS) Boron Aluminium Chromium Manganese Iron Nickel Copper Arsenic Selenium Cadmium Antimony Lead Uranium Silver PN-EN ISO 17294-2:2024-04","technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","test_object_en":"Water intended for human consumption","methodology_zh":"金属浓度","parameters_zh":[{"name":"硼","range":"(10,0-5000) μg/l"},{"name":"铝","range":"(10,0-5000) μg/l"},{"name":"铬","range":"(1,0-100) μg/l"},{"name":"锰","range":"(10,0-10000) μg/l"},{"name":"铁","range":"(10,0-25000) μg/l"},{"name":"镍","range":"(1,0-100) μg/l"},{"name":"铜","range":"(10,0-5000) μg/l"},{"name":"砷","range":"(1,0-100) μg/l"},{"name":"硒","range":"(1,0-100) μg/l"},{"name":"镉","range":"(1,0-100) μg/l"},{"name":"锑","range":"(1,0-100) μg/l"},{"name":"铅","range":"(1,0-100) μg/l"},{"name":"铀","range":"(1,0-100) μg/l"},{"name":"银","range":"(1,0-100) μg/l"}],"search_zh":"生活饮用水 金属浓度 电感耦合等离子体质谱法（ICP-MS） 硼 铝 铬 锰 铁 镍 铜 砷 硒 镉 锑 铅 铀 银 PN-EN ISO 17294-2:2024-04","technique_zh":"电感耦合等离子体质谱法（ICP-MS）","test_object_zh":"生活饮用水"},{"_id":"6a837436af14b9c0e7b1f387","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pozostałość pestycydów","parameters":[{"name":"Acefat","range":"(0,03-0,50) μg/l"},{"name":"Acetamipryd","range":"(0,03-0,50) μg/l"},{"name":"Atrazyna","range":"(0,03-0,50) μg/l"},{"name":"Azinfos etylowy","range":"(0,10-0,50) μg/l"},{"name":"Azinfos metylowy","range":"(0,10-0,50) μg/l"},{"name":"Azoksystrobina","range":"(0,03-0,50) μg/l"},{"name":"Chlorantraniliprol","range":"(0,03-0,50) μg/l"},{"name":"Chlorotoluron","range":"(0,03-0,50) μg/l"},{"name":"Cyjazofamid","range":"(0,10-0,50) μg/l"},{"name":"Diflubenzuron","range":"(0,05-0,50) μg/l"},{"name":"Dimetoat","range":"(0,03-0,50) μg/l"},{"name":"Dimetomorf","range":"(0,03-0,50) μg/l"},{"name":"Ditianon","range":"(0,05-0,50) μg/l"},{"name":"Etirimol","range":"(0,03-0,50) μg/l"},{"name":"Fipronil","range":"(0,03-0,50) μg/l"},{"name":"Fipronil sulfon","range":"(0,03-0,50) μg/l"},{"name":"Fluazifop (free acide)","range":"(0,10-0,50) μg/l"},{"name":"Fluoksastrobina","range":"(0,03-0,50) μg/l"},{"name":"Flutolanil","range":"(0,03-0,50) μg/l"},{"name":"Flusulfamid","range":"(0,03-0,50) μg/l"},{"name":"Foksym","range":"(0,10-0,50) μg/l"},{"name":"Formetanat","range":"(0,03-0,50) μg/l"},{"name":"Fosmet","range":"(0,10-0,50) μg/l"},{"name":"Fosmetu oxon","range":"(0,03-0,50) μg/l"},{"name":"Heksytiazoks","range":"(0,03-0,50) μg/l"},{"name":"Imidaklopryd","range":"(0,03-0,50) μg/l"},{"name":"Iprowalikarb","range":"(0,03-0,50) μg/l"},{"name":"Izoproturon","range":"(0,03-0,50) μg/l"},{"name":"Karbalyl","range":"(0,03-0,50) μg/l"},{"name":"Karbendazim","range":"(0,03-0,50) μg/l"},{"name":"Klotianidyna","range":"(0,10-0,50) μg/l"},{"name":"Lenacil","range":"(0,10-0,50) μg/l"},{"name":"Linuron","range":"(0,10-0,50) μg/l"},{"name":"Mandipropanid","range":"(0,10-0,50) μg/l"},{"name":"Mepanipirym","range":"(0,05-0,50) μg/l"},{"name":"Metamidofos","range":"(0,03-0,50) μg/l"},{"name":"Metalaksyl","range":"(0,03-0,50) μg/l"},{"name":"Metobromuron","range":"(0,10-0,50) μg/l"},{"name":"Metiokarb","range":"(0,05-0,50) μg/l"},{"name":"Metiokarbu sulfon","range":"(0,05-0,50) μg/l"},{"name":"Metiokarbu sulfotlenek","range":"(0,03-0,50) μg/l"},{"name":"Metoksyfenozyd","range":"(0,03-0,50) μg/l"},{"name":"Metomyl","range":"(0,05-0,50) μg/l"},{"name":"Nitenpyram","range":"(0,10-0,50) μg/l"},{"name":"Okadiksyl","range":"(0,03-0,50) μg/l"},{"name":"Oksydemeton metylowy","range":"(0,03-0,50) μg/l"},{"name":"Ometoat","range":"(0,03-0,50) μg/l"}],"technique":"Metoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC/MS/MS)","techniques":["Metoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC/MS/MS)"],"computed":[],"activity":"Pozostałość pestycydów\nZakres:\nAcefat (0,03-0,50) μg/l\nAcetamipryd (0,03-0,50) μg/l\nAtrazyna (0,03-0,50) μg/l\nAzinfos etylowy (0,10-0,50) μg/l\nAzinfos metylowy (0,10-0,50) μg/l\nAzoksystrobina (0,03-0,50) μg/l\nChlorantraniliprol (0,03-0,50) μg/l\nChlorotoluron (0,03-0,50) μg/l\nCyjazofamid (0,10-0,50) μg/l\nDiflubenzuron (0,05-0,50) μg/l\nDimetoat (0,03-0,50) μg/l\nDimetomorf (0,03-0,50) μg/l\nDitianon (0,05-0,50) μg/l\nEtirimol (0,03-0,50) μg/l\nFipronil (0,03-0,50) μg/l\nFipronil sulfon (0,03-0,50) μg/l\nFluazifop (free acide) (0,10-0,50) μg/l\nFluoksastrobina (0,03-0,50) μg/l\nFlutolanil (0,03-0,50) μg/l\nFlusulfamid (0,03-0,50) μg/l\nFoksym (0,10-0,50) μg/l\nFormetanat (0,03-0,50) μg/l\nFosmet (0,10-0,50) μg/l\nFosmetu oxon (0,03-0,50) μg/l\nHeksytiazoks (0,03-0,50) μg/l\nImidaklopryd (0,03-0,50) μg/l\nIprowalikarb (0,03-0,50) μg/l\nIzoproturon (0,03-0,50) μg/l\nKarbalyl (0,03-0,50) μg/l\nKarbendazim (0,03-0,50) μg/l\nKlotianidyna (0,10-0,50) μg/l\nLenacil (0,10-0,50) μg/l\nLinuron (0,10-0,50) μg/l\nMandipropanid (0,10-0,50) μg/l\nMepanipirym (0,05-0,50) μg/l\nMetamidofos (0,03-0,50) μg/l\nMetalaksyl (0,03-0,50) μg/l\nMetobromuron (0,10-0,50) μg/l\nMetiokarb (0,05-0,50) μg/l\nMetiokarbu sulfon (0,05-0,50) μg/l\nMetiokarbu sulfotlenek (0,03-0,50) μg/l\nMetoksyfenozyd (0,03-0,50) μg/l\nMetomyl (0,05-0,50) μg/l\nNitenpyram (0,10-0,50) μg/l\nOkadiksyl (0,03-0,50) μg/l\nOksydemeton metylowy (0,03-0,50) μg/l\nOmetoat (0,03-0,50) μg/l\nMetoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC/MS/MS)","reference":"PB/L – 107 wyd.1 z dnia 17.04.2020 r.","norm_bases":["PB/L – 107 wyd.1 z dnia 17.04.2020 r."],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Fizykochemicznych; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pozostałość pestycydów\nZakres:\nAcefat (0,03-0,50) μg/l\nAcetamipryd (0,03-0,50) μg/l\nAtrazyna (0,03-0,50) μg/l\nAzinfos etylowy (0,10-0,50) μg/l\nAzinfos metylowy (0,10-0,50) μg/l\nAzoksystrobina (0,03-0,50) μg/l\nChlorantraniliprol (0,03-0,50) μg/l\nChlorotoluron (0,03-0,50) μg/l\nCyjazofamid (0,10-0,50) μg/l\nDiflubenzuron (0,05-0,50) μg/l\nDimetoat (0,03-0,50) μg/l\nDimetomorf (0,03-0,50) μg/l\nDitianon (0,05-0,50) μg/l\nEtirimol (0,03-0,50) μg/l\nFipronil (0,03-0,50) μg/l\nFipronil sulfon (0,03-0,50) μg/l\nFluazifop (free acide) (0,10-0,50) μg/l\nFluoksastrobina (0,03-0,50) μg/l\nFlutolanil (0,03-0,50) μg/l\nFlusulfamid (0,03-0,50) μg/l\nFoksym (0,10-0,50) μg/l\nFormetanat (0,03-0,50) μg/l\nFosmet (0,10-0,50) μg/l\nFosmetu oxon (0,03-0,50) μg/l\nHeksytiazoks (0,03-0,50) μg/l\nImidaklopryd (0,03-0,50) μg/l\nIprowalikarb (0,03-0,50) μg/l\nIzoproturon (0,03-0,50) μg/l\nKarbalyl (0,03-0,50) μg/l\nKarbendazim (0,03-0,50) μg/l\nKlotianidyna (0,10-0,50) μg/l\nLenacil (0,10-0,50) μg/l\nLinuron (0,10-0,50) μg/l\nMandipropanid (0,10-0,50) μg/l\nMepanipirym (0,05-0,50) μg/l\nMetamidofos (0,03-0,50) μg/l\nMetalaksyl (0,03-0,50) μg/l\nMetobromuron (0,10-0,50) μg/l\nMetiokarb (0,05-0,50) μg/l\nMetiokarbu sulfon (0,05-0,50) μg/l\nMetiokarbu sulfotlenek (0,03-0,50) μg/l\nMetoksyfenozyd (0,03-0,50) μg/l\nMetomyl (0,05-0,50) μg/l\nNitenpyram (0,10-0,50) μg/l\nOkadiksyl (0,03-0,50) μg/l\nOksydemeton metylowy (0,03-0,50) μg/l\nOmetoat (0,03-0,50) μg/l\nMetoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC/MS/MS) PB/L – 107 wyd.1 z dnia 17.04.2020 r. Woda do spozycia przez ludzi Pozostalosc pestycydow\nZakres:\nAcefat (0,03-0,50) μg/l\nAcetamipryd (0,03-0,50) μg/l\nAtrazyna (0,03-0,50) μg/l\nAzinfos etylowy (0,10-0,50) μg/l\nAzinfos metylowy (0,10-0,50) μg/l\nAzoksystrobina (0,03-0,50) μg/l\nChlorantraniliprol (0,03-0,50) μg/l\nChlorotoluron (0,03-0,50) μg/l\nCyjazofamid (0,10-0,50) μg/l\nDiflubenzuron (0,05-0,50) μg/l\nDimetoat (0,03-0,50) μg/l\nDimetomorf (0,03-0,50) μg/l\nDitianon (0,05-0,50) μg/l\nEtirimol (0,03-0,50) μg/l\nFipronil (0,03-0,50) μg/l\nFipronil sulfon (0,03-0,50) μg/l\nFluazifop (free acide) (0,10-0,50) μg/l\nFluoksastrobina (0,03-0,50) μg/l\nFlutolanil (0,03-0,50) μg/l\nFlusulfamid (0,03-0,50) μg/l\nFoksym (0,10-0,50) μg/l\nFormetanat (0,03-0,50) μg/l\nFosmet (0,10-0,50) μg/l\nFosmetu oxon (0,03-0,50) μg/l\nHeksytiazoks (0,03-0,50) μg/l\nImidaklopryd (0,03-0,50) μg/l\nIprowalikarb (0,03-0,50) μg/l\nIzoproturon (0,03-0,50) μg/l\nKarbalyl (0,03-0,50) μg/l\nKarbendazim (0,03-0,50) μg/l\nKlotianidyna (0,10-0,50) μg/l\nLenacil (0,10-0,50) μg/l\nLinuron (0,10-0,50) μg/l\nMandipropanid (0,10-0,50) μg/l\nMepanipirym (0,05-0,50) μg/l\nMetamidofos (0,03-0,50) μg/l\nMetalaksyl (0,03-0,50) μg/l\nMetobromuron (0,10-0,50) μg/l\nMetiokarb (0,05-0,50) μg/l\nMetiokarbu sulfon (0,05-0,50) μg/l\nMetiokarbu sulfotlenek (0,03-0,50) μg/l\nMetoksyfenozyd (0,03-0,50) μg/l\nMetomyl (0,05-0,50) μg/l\nNitenpyram (0,10-0,50) μg/l\nOkadiksyl (0,03-0,50) μg/l\nOksydemeton metylowy (0,03-0,50) μg/l\nOmetoat (0,03-0,50) μg/l\nMetoda chromatografii cieczowej z detekcja tandemowa spektrometria mas (LC/MS/MS) PB/L – 107 wyd.1 z dnia 17.04.2020 r.","categories":["materials","water"],"row_index":60,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Pesticide residue","parameters_en":[{"name":"Acephate","range":"(0,03-0,50) μg/l"},{"name":"Acetamiprid","range":"(0,03-0,50) μg/l"},{"name":"Atrazine","range":"(0,03-0,50) μg/l"},{"name":"Azinphos-ethyl","range":"(0,10-0,50) μg/l"},{"name":"Azinphos-methyl","range":"(0,10-0,50) μg/l"},{"name":"Azoxystrobin","range":"(0,03-0,50) μg/l"},{"name":"Chlorantraniliprole","range":"(0,03-0,50) μg/l"},{"name":"Chlorotoluron","range":"(0,03-0,50) μg/l"},{"name":"Cyazofamid","range":"(0,10-0,50) μg/l"},{"name":"Diflubenzuron","range":"(0,05-0,50) μg/l"},{"name":"Dimethoate","range":"(0,03-0,50) μg/l"},{"name":"Dimethomorph","range":"(0,03-0,50) μg/l"},{"name":"Dithianon","range":"(0,05-0,50) μg/l"},{"name":"Ethirimol","range":"(0,03-0,50) μg/l"},{"name":"Fipronil","range":"(0,03-0,50) μg/l"},{"name":"Fipronil sulfone","range":"(0,03-0,50) μg/l"},{"name":"Fluazifop (free acide)","range":"(0,10-0,50) μg/l"},{"name":"Fluoxastrobin","range":"(0,03-0,50) μg/l"},{"name":"Flutolanil","range":"(0,03-0,50) μg/l"},{"name":"Flusulfamide","range":"(0,03-0,50) μg/l"},{"name":"Phoxim","range":"(0,10-0,50) μg/l"},{"name":"Formetanate","range":"(0,03-0,50) μg/l"},{"name":"Phosmet","range":"(0,10-0,50) μg/l"},{"name":"Phosmet oxon","range":"(0,03-0,50) μg/l"},{"name":"Hexythiazox","range":"(0,03-0,50) μg/l"},{"name":"Imidacloprid","range":"(0,03-0,50) μg/l"},{"name":"Iprovalicarb","range":"(0,03-0,50) μg/l"},{"name":"Isoproturon","range":"(0,03-0,50) μg/l"},{"name":"Carbaryl","range":"(0,03-0,50) μg/l"},{"name":"Carbendazim","range":"(0,03-0,50) μg/l"},{"name":"Clothianidin","range":"(0,10-0,50) μg/l"},{"name":"Lenacil","range":"(0,10-0,50) μg/l"},{"name":"Linuron","range":"(0,10-0,50) μg/l"},{"name":"Mandipropamid","range":"(0,10-0,50) μg/l"},{"name":"Mepanipyrim","range":"(0,05-0,50) μg/l"},{"name":"Methamidophos","range":"(0,03-0,50) μg/l"},{"name":"Metalaxyl","range":"(0,03-0,50) μg/l"},{"name":"Metobromuron","range":"(0,10-0,50) μg/l"},{"name":"Methiocarb","range":"(0,05-0,50) μg/l"},{"name":"Methiocarb sulfone","range":"(0,05-0,50) μg/l"},{"name":"Methiocarb sulfoxide","range":"(0,03-0,50) μg/l"},{"name":"Methoxyfenozide","range":"(0,03-0,50) μg/l"},{"name":"Methomyl","range":"(0,05-0,50) μg/l"},{"name":"Nitenpyram","range":"(0,10-0,50) μg/l"},{"name":"Oxadixyl","range":"(0,03-0,50) μg/l"},{"name":"Oxydemeton-methyl","range":"(0,03-0,50) μg/l"},{"name":"Omethoate","range":"(0,03-0,50) μg/l"}],"search_en":"Water intended for human consumption Pesticide residue Liquid chromatography with tandem mass spectrometry detection (LC/MS/MS) Acephate Acetamiprid Atrazine Azinphos-ethyl Azinphos-methyl Azoxystrobin Chlorantraniliprole Chlorotoluron Cyazofamid Diflubenzuron Dimethoate Dimethomorph Dithianon Ethirimol Fipronil Fipronil sulfone Fluazifop (free acide) Fluoxastrobin Flutolanil Flusulfamide Phoxim Formetanate Phosmet Phosmet oxon Hexythiazox Imidacloprid Iprovalicarb Isoproturon Carbaryl Carbendazim Clothianidin Lenacil Linuron Mandipropamid Mepanipyrim Methamidophos Metalaxyl Metobromuron Methiocarb Methiocarb sulfone Methiocarb sulfoxide Methoxyfenozide Methomyl Nitenpyram Oxadixyl Oxydemeton-methyl Omethoate PB/L – 107 wyd.1 z dnia 17.04.2020 r.","technique_en":"Liquid chromatography with tandem mass spectrometry detection (LC/MS/MS)","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 农药残留 液相色谱-串联质谱检测法（LC/MS/MS） 莠去津 PB/L – 107 wyd.1 z dnia 17.04.2020 r.","test_object_zh":"生活饮用水","methodology_zh":"农药残留","parameters_zh":[{"name":"Acefat","range":"(0,03-0,50) μg/l"},{"name":"Acetamipryd","range":"(0,03-0,50) μg/l"},{"name":"莠去津","range":"(0,03-0,50) μg/l"},{"name":"Azinfos etylowy","range":"(0,10-0,50) μg/l"},{"name":"Azinfos metylowy","range":"(0,10-0,50) μg/l"},{"name":"Azoksystrobina","range":"(0,03-0,50) μg/l"},{"name":"Chlorantraniliprol","range":"(0,03-0,50) μg/l"},{"name":"Chlorotoluron","range":"(0,03-0,50) μg/l"},{"name":"Cyjazofamid","range":"(0,10-0,50) μg/l"},{"name":"Diflubenzuron","range":"(0,05-0,50) μg/l"},{"name":"Dimetoat","range":"(0,03-0,50) μg/l"},{"name":"Dimetomorf","range":"(0,03-0,50) μg/l"},{"name":"Ditianon","range":"(0,05-0,50) μg/l"},{"name":"Etirimol","range":"(0,03-0,50) μg/l"},{"name":"Fipronil","range":"(0,03-0,50) μg/l"},{"name":"Fipronil sulfon","range":"(0,03-0,50) μg/l"},{"name":"Fluazifop (free acide)","range":"(0,10-0,50) μg/l"},{"name":"Fluoksastrobina","range":"(0,03-0,50) μg/l"},{"name":"Flutolanil","range":"(0,03-0,50) μg/l"},{"name":"Flusulfamid","range":"(0,03-0,50) μg/l"},{"name":"Foksym","range":"(0,10-0,50) μg/l"},{"name":"Formetanat","range":"(0,03-0,50) μg/l"},{"name":"Fosmet","range":"(0,10-0,50) μg/l"},{"name":"Fosmetu oxon","range":"(0,03-0,50) μg/l"},{"name":"Heksytiazoks","range":"(0,03-0,50) μg/l"},{"name":"Imidaklopryd","range":"(0,03-0,50) μg/l"},{"name":"Iprowalikarb","range":"(0,03-0,50) μg/l"},{"name":"Izoproturon","range":"(0,03-0,50) μg/l"},{"name":"Karbalyl","range":"(0,03-0,50) μg/l"},{"name":"Karbendazim","range":"(0,03-0,50) μg/l"},{"name":"Klotianidyna","range":"(0,10-0,50) μg/l"},{"name":"Lenacil","range":"(0,10-0,50) μg/l"},{"name":"Linuron","range":"(0,10-0,50) μg/l"},{"name":"Mandipropanid","range":"(0,10-0,50) μg/l"},{"name":"Mepanipirym","range":"(0,05-0,50) μg/l"},{"name":"Metamidofos","range":"(0,03-0,50) μg/l"},{"name":"Metalaksyl","range":"(0,03-0,50) μg/l"},{"name":"Metobromuron","range":"(0,10-0,50) μg/l"},{"name":"Metiokarb","range":"(0,05-0,50) μg/l"},{"name":"Metiokarbu sulfon","range":"(0,05-0,50) μg/l"},{"name":"Metiokarbu sulfotlenek","range":"(0,03-0,50) μg/l"},{"name":"Metoksyfenozyd","range":"(0,03-0,50) μg/l"},{"name":"Metomyl","range":"(0,05-0,50) μg/l"},{"name":"Nitenpyram","range":"(0,10-0,50) μg/l"},{"name":"Okadiksyl","range":"(0,03-0,50) μg/l"},{"name":"Oksydemeton metylowy","range":"(0,03-0,50) μg/l"},{"name":"Ometoat","range":"(0,03-0,50) μg/l"}],"technique_zh":"液相色谱-串联质谱检测法（LC/MS/MS）"},{"_id":"6a837436af14b9c0e7b1f388","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pozostałość pestycydów","parameters":[{"name":"Pencykuron","range":"(0,03-0,50) μg/l"},{"name":"Pimetrozyna","range":"(0,03-0,50) μg/l"},{"name":"Piryproksyfen","range":"(0,03-0,50) μg/l"},{"name":"Piraklostrobina","range":"(0,03-0,50) μg/l"},{"name":"Propamokarb","range":"(0,03-0,50) μg/l"},{"name":"Spiroksamina","range":"(0,03-0,50) μg/l"},{"name":"Tebufenozyd","range":"(0,05-0,50) μg/l"},{"name":"Tebufenpyrad","range":"(0,03-0,50) μg/l"},{"name":"Tetrakonazol","range":"(0,03-0,50) μg/l"},{"name":"Tiabendazol","range":"(0,03-0,50) μg/l"},{"name":"Tiodikarb","range":"(0,05-0,50) μg/l"},{"name":"Trifloksystrobina","range":"(0,03-0,50) μg/l"},{"name":"Tiametoksam","range":"(0,03-0,50) μg/l"},{"name":"Tiaklopryd","range":"(0,03-0,50) μg/l"},{"name":"Tiofanat metylu","range":"(0,03-0,50) μg/l"},{"name":"Forat oxon sulfon","range":"(0,03-0,50) μg/l"},{"name":"Forat sulfon","range":"(0,05-0,50) μg/l"},{"name":"Forat sulfotlenek","range":"(0,03-0,50) μg/l"},{"name":"Forat oxon","range":"(0,05-0,50) μg/l"}],"technique":"Metoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC/MS/MS)","techniques":["Metoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC/MS/MS)"],"computed":[],"activity":"Pozostałość pestycydów\nZakres:\nPencykuron (0,03-0,50) μg/l\nPimetrozyna (0,03-0,50) μg/l\nPiryproksyfen (0,03-0,50) μg/l\nPiraklostrobina (0,03-0,50) μg/l\nPropamokarb (0,03-0,50) μg/l\nSpiroksamina (0,03-0,50) μg/l\nTebufenozyd (0,05-0,50) μg/l\nTebufenpyrad (0,03-0,50) μg/l\nTetrakonazol (0,03-0,50) μg/l\nTiabendazol (0,03-0,50) μg/l\nTiodikarb (0,05-0,50) μg/l\nTrifloksystrobina (0,03-0,50) μg/l\nTiametoksam (0,03-0,50) μg/l\nTiaklopryd (0,03-0,50) μg/l\nTiofanat metylu (0,03-0,50) μg/l\nForat oxon sulfon (0,03-0,50) μg/l\nForat sulfon (0,05-0,50) μg/l\nForat sulfotlenek (0,03-0,50) μg/l\nForat oxon (0,05-0,50) μg/l\nMetoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC/MS/MS)","reference":"PB/L – 107 wyd.1 z dnia 17.04.2020 r.","norm_bases":["PB/L – 107 wyd.1 z dnia 17.04.2020 r."],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Fizykochemicznych; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pozostałość pestycydów\nZakres:\nPencykuron (0,03-0,50) μg/l\nPimetrozyna (0,03-0,50) μg/l\nPiryproksyfen (0,03-0,50) μg/l\nPiraklostrobina (0,03-0,50) μg/l\nPropamokarb (0,03-0,50) μg/l\nSpiroksamina (0,03-0,50) μg/l\nTebufenozyd (0,05-0,50) μg/l\nTebufenpyrad (0,03-0,50) μg/l\nTetrakonazol (0,03-0,50) μg/l\nTiabendazol (0,03-0,50) μg/l\nTiodikarb (0,05-0,50) μg/l\nTrifloksystrobina (0,03-0,50) μg/l\nTiametoksam (0,03-0,50) μg/l\nTiaklopryd (0,03-0,50) μg/l\nTiofanat metylu (0,03-0,50) μg/l\nForat oxon sulfon (0,03-0,50) μg/l\nForat sulfon (0,05-0,50) μg/l\nForat sulfotlenek (0,03-0,50) μg/l\nForat oxon (0,05-0,50) μg/l\nMetoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC/MS/MS) PB/L – 107 wyd.1 z dnia 17.04.2020 r. Woda do spozycia przez ludzi Pozostalosc pestycydow\nZakres:\nPencykuron (0,03-0,50) μg/l\nPimetrozyna (0,03-0,50) μg/l\nPiryproksyfen (0,03-0,50) μg/l\nPiraklostrobina (0,03-0,50) μg/l\nPropamokarb (0,03-0,50) μg/l\nSpiroksamina (0,03-0,50) μg/l\nTebufenozyd (0,05-0,50) μg/l\nTebufenpyrad (0,03-0,50) μg/l\nTetrakonazol (0,03-0,50) μg/l\nTiabendazol (0,03-0,50) μg/l\nTiodikarb (0,05-0,50) μg/l\nTrifloksystrobina (0,03-0,50) μg/l\nTiametoksam (0,03-0,50) μg/l\nTiaklopryd (0,03-0,50) μg/l\nTiofanat metylu (0,03-0,50) μg/l\nForat oxon sulfon (0,03-0,50) μg/l\nForat sulfon (0,05-0,50) μg/l\nForat sulfotlenek (0,03-0,50) μg/l\nForat oxon (0,05-0,50) μg/l\nMetoda chromatografii cieczowej z detekcja tandemowa spektrometria mas (LC/MS/MS) PB/L – 107 wyd.1 z dnia 17.04.2020 r.","categories":["water"],"row_index":61,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Pesticide residue","parameters_en":[{"name":"Pencycuron","range":"(0,03-0,50) μg/l"},{"name":"Pymetrozine","range":"(0,03-0,50) μg/l"},{"name":"Pyriproxyfen","range":"(0,03-0,50) μg/l"},{"name":"Pyraclostrobin","range":"(0,03-0,50) μg/l"},{"name":"Propamocarb","range":"(0,03-0,50) μg/l"},{"name":"Spiroxamine","range":"(0,03-0,50) μg/l"},{"name":"Tebufenozide","range":"(0,05-0,50) μg/l"},{"name":"Tebufenpyrad","range":"(0,03-0,50) μg/l"},{"name":"Tetraconazole","range":"(0,03-0,50) μg/l"},{"name":"Thiabendazole","range":"(0,03-0,50) μg/l"},{"name":"Thiodicarb","range":"(0,05-0,50) μg/l"},{"name":"Trifloxystrobin","range":"(0,03-0,50) μg/l"},{"name":"Thiamethoxam","range":"(0,03-0,50) μg/l"},{"name":"Thiacloprid","range":"(0,03-0,50) μg/l"},{"name":"Thiophanate-methyl","range":"(0,03-0,50) μg/l"},{"name":"Phorate oxon sulfone","range":"(0,03-0,50) μg/l"},{"name":"Phorate sulfone","range":"(0,05-0,50) μg/l"},{"name":"Phorate sulfoxide","range":"(0,03-0,50) μg/l"},{"name":"Phorate oxon","range":"(0,05-0,50) μg/l"}],"search_en":"Water intended for human consumption Pesticide residue Liquid chromatography with tandem mass spectrometry detection (LC/MS/MS) Pencycuron Pymetrozine Pyriproxyfen Pyraclostrobin Propamocarb Spiroxamine Tebufenozide Tebufenpyrad Tetraconazole Thiabendazole Thiodicarb Trifloxystrobin Thiamethoxam Thiacloprid Thiophanate-methyl Phorate oxon sulfone Phorate sulfone Phorate sulfoxide Phorate oxon PB/L – 107 wyd.1 z dnia 17.04.2020 r.","technique_en":"Liquid chromatography with tandem mass spectrometry detection (LC/MS/MS)","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 农药残留 液相色谱-串联质谱检测法（LC/MS/MS） PB/L – 107 wyd.1 z dnia 17.04.2020 r.","test_object_zh":"生活饮用水","methodology_zh":"农药残留","technique_zh":"液相色谱-串联质谱检测法（LC/MS/MS）"},{"_id":"6a837436af14b9c0e7b1f389","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Suma pestycydów (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma pestycydów (z obliczeń)","reference":"PB/L – 107 wyd.1 z dnia 17.04.2020 r.","norm_bases":["PB/L – 107 wyd.1 z dnia 17.04.2020 r."],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Pracownia Badań Fizykochemicznych; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Suma pestycydów (z obliczeń) PB/L – 107 wyd.1 z dnia 17.04.2020 r. Woda do spozycia przez ludzi Suma pestycydow (z obliczen) PB/L – 107 wyd.1 z dnia 17.04.2020 r.","categories":["water"],"row_index":62,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of pesticides (calculated)","search_en":"Water intended for human consumption Sum of pesticides (calculated) PB/L – 107 wyd.1 z dnia 17.04.2020 r.","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 农药总量（由计算得出） PB/L – 107 wyd.1 z dnia 17.04.2020 r.","test_object_zh":"生活饮用水","methodology_zh":"农药总量（由计算得出）"},{"_id":"6a837436af14b9c0e7b1f38a","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-5:2017-10","norm_bases":["PN-ISO 5667-5:2017-10"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-5:2017-10 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-5:2017-10","categories":["water"],"row_index":63,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Water intended for human consumption Sampling for chemical and physical testing PN-ISO 5667-5:2017-10","test_object_en":"Water intended for human consumption","methodology_zh":"化学与物理检测用样品采集","search_zh":"生活饮用水 化学与物理检测用样品采集 PN-ISO 5667-5:2017-10","test_object_zh":"生活饮用水"},{"_id":"6a837436af14b9c0e7b1f38b","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie azotynów","parameters":[{"name":"Zakres","range":"(0,010 – 1,5) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotynów\nZakres (0,010 – 1,5) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie azotynów\nZakres (0,010 – 1,5) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, Woda do spozycia przez ludzi Stezenie azotynow\nZakres (0,010 – 1,5) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":64,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite concentration","parameters_en":[{"name":"Range","range":"(0,010 – 1,5) mg/l"}],"search_en":"Water, Water intended for human consumption Nitrite concentration Spectrophotometric method Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,010 – 1,5) mg/l"}],"search_zh":"水、生活饮用水 亚硝酸盐浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a837436af14b9c0e7b1f38c","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(148 – 1410) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (148 – 1410) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Przewodność elektryczna właściwa\nZakres (148 – 1410) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, Woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa\nZakres (148 – 1410) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":65,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(148 – 1410) μS/cm"}],"search_en":"Water, Water intended for human consumption Electrical conductivity Conductometric method Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(148 – 1410) μS/cm"}],"search_zh":"水、生活饮用水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、生活饮用水"},{"_id":"6a837436af14b9c0e7b1f38d","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie jonu amonowego","parameters":[{"name":"Zakres","range":"(0,030 – 5,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie jonu amonowego\nZakres (0,030 – 5,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie jonu amonowego\nZakres (0,030 – 5,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, Woda do spozycia przez ludzi Stezenie jonu amonowego\nZakres (0,030 – 5,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":66,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium ion concentration","parameters_en":[{"name":"Range","range":"(0,030 – 5,0) mg/l"}],"search_en":"Water, Water intended for human consumption Ammonium ion concentration Spectrophotometric method Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"铵离子浓度","parameters_zh":[{"name":"范围","range":"(0,030 – 5,0) mg/l"}],"search_zh":"水、生活饮用水 铵离子浓度 分光光度法 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a837436af14b9c0e7b1f38e","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie azotanów","parameters":[{"name":"Zakres","range":"(0,90 – 60) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotanów\nZakres (0,90 – 60) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576.08","norm_bases":["PN-82/C-04576.08"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie azotanów\nZakres (0,90 – 60) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08 Woda, Woda do spozycia przez ludzi Stezenie azotanow\nZakres (0,90 – 60) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08","categories":["water"],"row_index":67,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate concentration","parameters_en":[{"name":"Range","range":"(0,90 – 60) mg/l"}],"search_en":"Water, Water intended for human consumption Nitrate concentration Spectrophotometric method Range PN-82/C-04576.08","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,90 – 60) mg/l"}],"search_zh":"水、生活饮用水 硝酸盐浓度 分光光度法 范围 PN-82/C-04576.08","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a837436af14b9c0e7b1f38f","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"pH","parameters":[{"name":"Zakres","range":"3,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 3,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi pH\nZakres 3,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, Woda do spozycia przez ludzi pH\nZakres 3,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":68,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"3,0 – 10,0"}],"search_en":"Water, Water intended for human consumption pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"3,0 – 10,0"}],"search_zh":"水、生活饮用水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、生活饮用水"},{"_id":"6a837436af14b9c0e7b1f390","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,10 – 1000) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,10 – 1000) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Mętność\nZakres (0,10 – 1000) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda, Woda do spozycia przez ludzi Metnosc\nZakres (0,10 – 1000) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":69,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,10 – 1000) NTU"}],"search_en":"Water, Water intended for human consumption Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09","technique_en":"Nephelometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,10 – 1000) NTU"}],"search_zh":"水、生活饮用水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"水、生活饮用水"},{"_id":"6a837436af14b9c0e7b1f391","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(5,0 – 40) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Barwa\nZakres (5,0 – 40) mg/l Pt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012+Ap1:2015-06 pkt 6","norm_bases":["PN-EN ISO 7887:2012+Ap1:2015-06 pkt 6"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Barwa\nZakres (5,0 – 40) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012+Ap1:2015-06 pkt 6 Woda, Woda do spozycia przez ludzi Barwa\nZakres (5,0 – 40) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012+Ap1:2015-06 pkt 6","categories":["water"],"row_index":70,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"(5,0 – 40) mg/l Pt"}],"search_en":"Water, Water intended for human consumption Colour Spectrophotometric method Range PN-EN ISO 7887:2012+Ap1:2015-06 pkt 6","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(5,0 – 40) mg/l Pt"}],"search_zh":"水、生活饮用水 色度 分光光度法 范围 PN-EN ISO 7887:2012+Ap1:2015-06 pkt 6","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a837436af14b9c0e7b1f392","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie fluorków","parameters":[{"name":"Zakres","range":"(0,10 – 4,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fluorków\nZakres (0,10 – 4,0) mg/l\nMetoda spektrofotometryczna","reference":"PB/L-115, wyd.1 z 09.02.2026 r. | na podstawie metody Hach nr 8029","norm_bases":["PB/L-115, wyd.1 z 09.02.2026 r.","na podstawie metody Hach nr 8029"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie fluorków\nZakres (0,10 – 4,0) mg/l\nMetoda spektrofotometryczna PB/L-115, wyd.1 z 09.02.2026 r. | na podstawie metody Hach nr 8029 Woda, Woda do spozycia przez ludzi Stezenie fluorkow\nZakres (0,10 – 4,0) mg/l\nMetoda spektrofotometryczna PB/L-115, wyd.1 z 09.02.2026 r. | na podstawie metody Hach nr 8029","categories":["water"],"row_index":71,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fluoride concentration","parameters_en":[{"name":"Range","range":"(0,10 – 4,0) mg/l"}],"search_en":"Water, Water intended for human consumption Fluoride concentration Spectrophotometric method Range PB/L-115, wyd.1 z 09.02.2026 r. | na podstawie metody Hach nr 8029","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,10 – 4,0) mg/l"}],"search_zh":"水、生活饮用水 氟化物浓度 分光光度法 范围 PB/L-115, wyd.1 z 09.02.2026 r. | na podstawie metody Hach nr 8029","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","methodology_zh":"氟化物浓度"},{"_id":"6a837436af14b9c0e7b1f393","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie chloru wolnego","parameters":[{"name":"Zakres","range":"(0,050 – 4,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chloru wolnego\nZakres (0,050 – 4,0) mg/l\nMetoda spektrofotometryczna","reference":"PB/L-116, wyd. 1 z 09.02.2026 r. | na podstawie metody Hach nr 8021","norm_bases":["PB/L-116, wyd. 1 z 09.02.2026 r.","na podstawie metody Hach nr 8021"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie chloru wolnego\nZakres (0,050 – 4,0) mg/l\nMetoda spektrofotometryczna PB/L-116, wyd. 1 z 09.02.2026 r. | na podstawie metody Hach nr 8021 Woda, Woda do spozycia przez ludzi Stezenie chloru wolnego\nZakres (0,050 – 4,0) mg/l\nMetoda spektrofotometryczna PB/L-116, wyd. 1 z 09.02.2026 r. | na podstawie metody Hach nr 8021","categories":["water"],"row_index":72,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free chlorine concentration","parameters_en":[{"name":"Range","range":"(0,050 – 4,0) mg/l"}],"search_en":"Water, Water intended for human consumption Free chlorine concentration Spectrophotometric method Range PB/L-116, wyd. 1 z 09.02.2026 r. | na podstawie metody Hach nr 8021","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"游离氯浓度","parameters_zh":[{"name":"范围","range":"(0,050 – 4,0) mg/l"}],"search_zh":"水、生活饮用水 游离氯浓度 分光光度法 范围 PB/L-116, wyd. 1 z 09.02.2026 r. | na podstawie metody Hach nr 8021","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a837436af14b9c0e7b1f394","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(10 – 350) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie siarczanów\nZakres (10 – 350) mg/l\nMetoda spektrofotometryczna","reference":"PB/L-117, wyd. 1 z 09.02.2026 r. | na podstawie metody Hach nr 8051","norm_bases":["PB/L-117, wyd. 1 z 09.02.2026 r.","na podstawie metody Hach nr 8051"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie siarczanów\nZakres (10 – 350) mg/l\nMetoda spektrofotometryczna PB/L-117, wyd. 1 z 09.02.2026 r. | na podstawie metody Hach nr 8051 Woda, Woda do spozycia przez ludzi Stezenie siarczanow\nZakres (10 – 350) mg/l\nMetoda spektrofotometryczna PB/L-117, wyd. 1 z 09.02.2026 r. | na podstawie metody Hach nr 8051","categories":["water"],"row_index":73,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Range","range":"(10 – 350) mg/l"}],"search_en":"Water, Water intended for human consumption Sulfate concentration Spectrophotometric method Range PB/L-117, wyd. 1 z 09.02.2026 r. | na podstawie metody Hach nr 8051","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(10 – 350) mg/l"}],"search_zh":"水、生活饮用水 硫酸盐浓度 分光光度法 范围 PB/L-117, wyd. 1 z 09.02.2026 r. | na podstawie metody Hach nr 8051","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a837436af14b9c0e7b1f395","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5,0 – 400) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5,0 – 400) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie chlorków\nZakres (5,0 – 400) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda, Woda do spozycia przez ludzi Stezenie chlorkow\nZakres (5,0 – 400) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":74,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5,0 – 400) mg/l"}],"search_en":"Water, Water intended for human consumption Chloride concentration Titrimetric method Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,0 – 400) mg/l"}],"search_zh":"水、生活饮用水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水、生活饮用水"},{"_id":"6a837436af14b9c0e7b1f396","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie glinu","parameters":[{"name":"Zakres","range":"(0,020 – 0,25) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie glinu\nZakres (0,020 – 0,25) mg/l\nMetoda spektrofotometryczna","reference":"PB/L-118, wyd. 1 z 09.02.2026 r. | na podstawie metody Hach nr 8326","norm_bases":["PB/L-118, wyd. 1 z 09.02.2026 r.","na podstawie metody Hach nr 8326"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie glinu\nZakres (0,020 – 0,25) mg/l\nMetoda spektrofotometryczna PB/L-118, wyd. 1 z 09.02.2026 r. | na podstawie metody Hach nr 8326 Woda, Woda do spozycia przez ludzi Stezenie glinu\nZakres (0,020 – 0,25) mg/l\nMetoda spektrofotometryczna PB/L-118, wyd. 1 z 09.02.2026 r. | na podstawie metody Hach nr 8326","categories":["water"],"row_index":75,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Aluminium concentration","parameters_en":[{"name":"Range","range":"(0,020 – 0,25) mg/l"}],"search_en":"Water, Water intended for human consumption Aluminium concentration Spectrophotometric method Range PB/L-118, wyd. 1 z 09.02.2026 r. | na podstawie metody Hach nr 8326","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,020 – 0,25) mg/l"}],"search_zh":"水、生活饮用水 铝浓度 分光光度法 范围 PB/L-118, wyd. 1 z 09.02.2026 r. | na podstawie metody Hach nr 8326","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","methodology_zh":"铝浓度"},{"_id":"6a837436af14b9c0e7b1f397","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Indeks nadmanganianowy","parameters":[{"name":"Zakres","range":"(1,0 – 20) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Indeks nadmanganianowy\nZakres (1,0 – 20) mg/l O2\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Indeks nadmanganianowy\nZakres (1,0 – 20) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda, Woda do spozycia przez ludzi Indeks nadmanganianowy\nZakres (1,0 – 20) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":76,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Permanganate index","parameters_en":[{"name":"Range","range":"(1,0 – 20) mg/l O2"}],"search_en":"Water, Water intended for human consumption Permanganate index Titrimetric method Range PN-EN ISO 8467:2001","technique_en":"Titrimetric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"高锰酸盐指数","parameters_zh":[{"name":"范围","range":"(1,0 – 20) mg/l O2"}],"search_zh":"水、生活饮用水 高锰酸盐指数 滴定法 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"水、生活饮用水"},{"_id":"6a837436af14b9c0e7b1f398","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie fluorków","parameters":[{"name":"Zakres","range":"(0,10 – 2,0) mg/l"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"Stężenie fluorków\nZakres (0,10 – 2,0) mg/l\nMetoda potencjometryczna","reference":"PN-78/C-04588/03","norm_bases":["PN-78/C-04588/03"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie fluorków\nZakres (0,10 – 2,0) mg/l\nMetoda potencjometryczna PN-78/C-04588/03 Woda, Woda do spozycia przez ludzi Stezenie fluorkow\nZakres (0,10 – 2,0) mg/l\nMetoda potencjometryczna PN-78/C-04588/03","categories":["water"],"row_index":77,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fluoride concentration","parameters_en":[{"name":"Range","range":"(0,10 – 2,0) mg/l"}],"search_en":"Water, Water intended for human consumption Fluoride concentration Potentiometric method Range PN-78/C-04588/03","technique_en":"Potentiometric method","test_object_en":"Water, Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,10 – 2,0) mg/l"}],"search_zh":"水、生活饮用水 氟化物浓度 电位法 范围 PN-78/C-04588/03","technique_zh":"电位法","test_object_zh":"水、生活饮用水","methodology_zh":"氟化物浓度"},{"_id":"6a837436af14b9c0e7b1f399","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Chlor całkowity","parameters":[{"name":"Zakres","range":"(0,050 – 4,0) mg/l"},{"name":"Chlor związany (z obliczeń)"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chlor całkowity\nZakres:\nZakres (0,050 – 4,0) mg/l\nChlor związany (z obliczeń)\nMetoda spektrofotometryczna","reference":"PB/L-119 wyd. 1 z 09.02.2026 | na podstawie metody Hach nr 8167","norm_bases":["PB/L-119 wyd. 1 z 09.02.2026","na podstawie metody Hach nr 8167"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Chlor całkowity\nZakres:\nZakres (0,050 – 4,0) mg/l\nChlor związany (z obliczeń)\nMetoda spektrofotometryczna PB/L-119 wyd. 1 z 09.02.2026 | na podstawie metody Hach nr 8167 Woda, Woda do spozycia przez ludzi Chlor calkowity\nZakres:\nZakres (0,050 – 4,0) mg/l\nChlor zwiazany (z obliczen)\nMetoda spektrofotometryczna PB/L-119 wyd. 1 z 09.02.2026 | na podstawie metody Hach nr 8167","categories":["water"],"row_index":78,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total chlorine","parameters_en":[{"name":"Range","range":"(0,050 – 4,0) mg/l"},{"name":"Combined chlorine (calculated)"}],"search_en":"Water, Water intended for human consumption Total chlorine Spectrophotometric method Range Combined chlorine (calculated) PB/L-119 wyd. 1 z 09.02.2026 | na podstawie metody Hach nr 8167","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,050 – 4,0) mg/l"},{"name":"化合氯（由计算得出）"}],"search_zh":"水、生活饮用水 分光光度法 范围 化合氯（由计算得出） PB/L-119 wyd. 1 z 09.02.2026 | na podstawie metody Hach nr 8167","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a837436af14b9c0e7b1f39a","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)","parameters":[{"name":"Zakres","range":"(5 – 700) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (5 – 700) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (5 – 700) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999 Woda, Woda do spozycia przez ludzi Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna)\nZakres (5 – 700) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":79,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total content of calcium and magnesium (total hardness)","parameters_en":[{"name":"Range","range":"(5 – 700) mg/l CaCO3"}],"search_en":"Water, Water intended for human consumption Total content of calcium and magnesium (total hardness) Titrimetric method Range PN-ISO 6059:1999","technique_en":"Titrimetric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"钙与镁总量（总硬度）","parameters_zh":[{"name":"范围","range":"(5 – 700) mg/l CaCO3"}],"search_zh":"水、生活饮用水 钙与镁总量（总硬度） 滴定法 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"水、生活饮用水"},{"_id":"6a837436af14b9c0e7b1f39b","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie wapnia","parameters":[{"name":"Zakres","range":"(2 – 100) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie wapnia\nZakres (2 – 100) mg/l\nMetoda miareczkowa","reference":"PN-ISO 6058:1999","norm_bases":["PN-ISO 6058:1999"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie wapnia\nZakres (2 – 100) mg/l\nMetoda miareczkowa PN-ISO 6058:1999 Woda, Woda do spozycia przez ludzi Stezenie wapnia\nZakres (2 – 100) mg/l\nMetoda miareczkowa PN-ISO 6058:1999","categories":["water"],"row_index":80,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Calcium concentration","parameters_en":[{"name":"Range","range":"(2 – 100) mg/l"}],"search_en":"Water, Water intended for human consumption Calcium concentration Titrimetric method Range PN-ISO 6058:1999","technique_en":"Titrimetric method","test_object_en":"Water, Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(2 – 100) mg/l"}],"search_zh":"水、生活饮用水 钙浓度 滴定法 范围 PN-ISO 6058:1999","technique_zh":"滴定法","test_object_zh":"水、生活饮用水","methodology_zh":"钙浓度"},{"_id":"6a837436af14b9c0e7b1f39c","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie magnezu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie magnezu (z obliczeń)","reference":"PN-99/C-04554/04 załącznik A","norm_bases":["PN-99/C-04554/04 załącznik A"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie magnezu (z obliczeń) PN-99/C-04554/04 załącznik A Woda, Woda do spozycia przez ludzi Stezenie magnezu (z obliczen) PN-99/C-04554/04 zalacznik A","categories":["water"],"row_index":81,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnesium concentration (calculated)","search_en":"Water, Water intended for human consumption Magnesium concentration (calculated) PN-99/C-04554/04 załącznik A","test_object_en":"Water, Water intended for human consumption","search_zh":"水、生活饮用水 镁浓度（计算值） PN-99/C-04554/04 załącznik A","test_object_zh":"水、生活饮用水","methodology_zh":"镁浓度（计算值）"},{"_id":"6a837436af14b9c0e7b1f39d","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Woda na pływalniach","methodology":"Pobieranie próbek do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.5, 4.4.6","norm_bases":["PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.5, 4.4.6"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Woda na pływalniach Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.5, 4.4.6 Woda, Woda do spozycia przez ludzi, Woda na plywalniach Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007 z wylaczeniem pkt. 4.4.5, 4.4.6","categories":["water","microbiology"],"row_index":82,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for microbiological testing","search_en":"Water, Water intended for human consumption, Swimming pool water Sampling for microbiological testing PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.5, 4.4.6","test_object_en":"Water, Water intended for human consumption, Swimming pool water","methodology_zh":"微生物检测用样品采集","search_zh":"水、生活饮用水、游泳池水 微生物检测用样品采集 PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.5, 4.4.6","test_object_zh":"水、生活饮用水、游泳池水"},{"_id":"6a837436af14b9c0e7b1f39e","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w 22°C","parameters":[],"technique":"Metoda płytkowa – posiew wgłębny","techniques":["Metoda płytkowa – posiew wgłębny"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w 22°C\nMetoda płytkowa – posiew wgłębny","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 22°C\nMetoda płytkowa – posiew wgłębny PN-EN ISO 6222:2004 Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 22°C\nMetoda plytkowa – posiew wglebny PN-EN ISO 6222:2004","categories":["water"],"row_index":83,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total viable count at 22°C","search_en":"Water intended for human consumption Total viable count at 22°C PN-EN ISO 6222:2004","test_object_en":"Water intended for human consumption","methodology_zh":"22°C 微生物总数","search_zh":"生活饮用水 22°C 微生物总数 PN-EN ISO 6222:2004","test_object_zh":"生活饮用水"},{"_id":"6a837436af14b9c0e7b1f39f","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w 36°C","parameters":[],"technique":"Metoda płytkowa – posiew wgłębny","techniques":["Metoda płytkowa – posiew wgłębny"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w 36°C\nMetoda płytkowa – posiew wgłębny","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 36°C\nMetoda płytkowa – posiew wgłębny PN-EN ISO 6222:2004 Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 36°C\nMetoda plytkowa – posiew wglebny PN-EN ISO 6222:2004","categories":["water"],"row_index":84,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total viable count at 36°C","search_en":"Water intended for human consumption Total viable count at 36°C PN-EN ISO 6222:2004","test_object_en":"Water intended for human consumption","methodology_zh":"36°C 微生物总数","search_zh":"生活饮用水 36°C 微生物总数 PN-EN ISO 6222:2004","test_object_zh":"生活饮用水"},{"_id":"6a837436af14b9c0e7b1f3a0","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba enterokoków kałowych","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba enterokoków kałowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba enterokoków kałowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda do spozycia przez ludzi Liczba enterokokow kalowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":85,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Intestinal enterococci count","search_en":"Water intended for human consumption Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption","methodology_zh":"粪肠球菌计数","search_zh":"生活饮用水 粪肠球菌计数 膜过滤法 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"生活饮用水"},{"_id":"6a837436af14b9c0e7b1f3a1","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba bakterii Legionella sp. Matryca A Procedura 5, podłoże A (BCYE), Procedura 7, podłoże C (GVPC)","parameters":[{"name":"Zakres","range":"od 1 jtk/100 ml; od 1 jtk / 1000 ml"}],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii Legionella sp. Matryca A Procedura 5, podłoże A (BCYE), Procedura 7, podłoże C (GVPC)\nZakres od 1 jtk/100 ml; od 1 jtk / 1000 ml\nMetoda filtracji membranowej","reference":"PN-EN ISO 11731:2017-08 +Ap1:2019-12","norm_bases":["PN-EN ISO 11731:2017-08 +Ap1:2019-12"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba bakterii Legionella sp. Matryca A Procedura 5, podłoże A (BCYE), Procedura 7, podłoże C (GVPC)\nZakres od 1 jtk/100 ml; od 1 jtk / 1000 ml\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 +Ap1:2019-12 Woda do spozycia przez ludzi Liczba bakterii Legionella sp. Matryca A Procedura 5, podloze A (BCYE), Procedura 7, podloze C (GVPC)\nZakres od 1 jtk/100 ml; od 1 jtk / 1000 ml\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 +Ap1:2019-12","categories":["microbiology","water"],"row_index":86,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"od 1 jtk/100 ml; od 1 jtk / 1000 ml"}],"search_en":"Water intended for human consumption Membrane filtration method Range PN-EN ISO 11731:2017-08 +Ap1:2019-12","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"od 1 jtk/100 ml; od 1 jtk / 1000 ml"}],"search_zh":"生活饮用水 膜过滤法 范围 PN-EN ISO 11731:2017-08 +Ap1:2019-12","technique_zh":"膜过滤法","test_object_zh":"生活饮用水"},{"_id":"6a837436af14b9c0e7b1f3a2","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda do spozycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":87,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Escherichia coli count","search_en":"Water intended for human consumption Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"生活饮用水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"生活饮用水"},{"_id":"6a837436af14b9c0e7b1f3a3","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba bakterii grupy coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda do spozycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":88,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Coliform bacteria count","search_en":"Water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption","methodology_zh":"大肠菌群计数","search_zh":"生活饮用水 大肠菌群计数 膜过滤法 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"生活饮用水"},{"_id":"6a837436af14b9c0e7b1f3a4","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba Pseudomonas aeruginosa","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009 Woda do spozycia przez ludzi Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water"],"row_index":89,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Pseudomonas aeruginosa count","search_en":"Water intended for human consumption Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption","methodology_zh":"铜绿假单胞菌计数","search_zh":"生活饮用水 铜绿假单胞菌计数 膜过滤法 PN-EN ISO 16266:2009","technique_zh":"膜过滤法","test_object_zh":"生活饮用水"},{"_id":"6a837436af14b9c0e7b1f3a5","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Ogólna liczba mikroorganizmów w 36°C","parameters":[],"technique":"Metoda płytkowa – posiew wgłębny","techniques":["Metoda płytkowa – posiew wgłębny"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w 36°C\nMetoda płytkowa – posiew wgłębny","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Ogólna liczba mikroorganizmów w 36°C\nMetoda płytkowa – posiew wgłębny PN-EN ISO 6222:2004 Woda na plywalniach Ogolna liczba mikroorganizmow w 36°C\nMetoda plytkowa – posiew wglebny PN-EN ISO 6222:2004","categories":["water"],"row_index":90,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total viable count at 36°C","search_en":"Swimming pool water Total viable count at 36°C PN-EN ISO 6222:2004","test_object_en":"Swimming pool water","methodology_zh":"36°C 微生物总数","search_zh":"游泳池水 36°C 微生物总数 PN-EN ISO 6222:2004","test_object_zh":"游泳池水"},{"_id":"6a837436af14b9c0e7b1f3a6","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Liczba Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda na plywalniach Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":91,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Escherichia coli count","search_en":"Swimming pool water Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Swimming pool water","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"游泳池水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"游泳池水"},{"_id":"6a837436af14b9c0e7b1f3a7","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Liczba gronkowców koagulazododatnich","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba gronkowców koagulazododatnich\nMetoda filtracji membranowej","reference":"PB/L-114, wyd. 1 z 09.02.2026 r.","norm_bases":["PB/L-114, wyd. 1 z 09.02.2026 r."],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Liczba gronkowców koagulazododatnich\nMetoda filtracji membranowej PB/L-114, wyd. 1 z 09.02.2026 r. Woda na plywalniach Liczba gronkowcow koagulazododatnich\nMetoda filtracji membranowej PB/L-114, wyd. 1 z 09.02.2026 r.","categories":["water"],"row_index":92,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Coagulase-positive staphylococci count","search_en":"Swimming pool water Coagulase-positive staphylococci count Membrane filtration method PB/L-114, wyd. 1 z 09.02.2026 r.","technique_en":"Membrane filtration method","test_object_en":"Swimming pool water","search_zh":"游泳池水 凝固酶阳性葡萄球菌计数 膜过滤法 PB/L-114, wyd. 1 z 09.02.2026 r.","technique_zh":"膜过滤法","test_object_zh":"游泳池水","methodology_zh":"凝固酶阳性葡萄球菌计数"},{"_id":"6a837436af14b9c0e7b1f3a8","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Liczba bakterii Legionella sp. Matryca A Procedura 5, podłoże A (BCYE), Procedura 7, podłoże C (GVPC)","parameters":[{"name":"Zakres","range":"od 1 jtk/100 ml"}],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii Legionella sp. Matryca A Procedura 5, podłoże A (BCYE), Procedura 7, podłoże C (GVPC)\nZakres od 1 jtk/100 ml\nMetoda filtracji membranowej","reference":"PN-EN ISO 11731:2017-08 +Ap1:2019-12","norm_bases":["PN-EN ISO 11731:2017-08 +Ap1:2019-12"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Liczba bakterii Legionella sp. Matryca A Procedura 5, podłoże A (BCYE), Procedura 7, podłoże C (GVPC)\nZakres od 1 jtk/100 ml\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 +Ap1:2019-12 Woda na plywalniach Liczba bakterii Legionella sp. Matryca A Procedura 5, podloze A (BCYE), Procedura 7, podloze C (GVPC)\nZakres od 1 jtk/100 ml\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 +Ap1:2019-12","categories":["microbiology","water"],"row_index":93,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"od 1 jtk/100 ml"}],"search_en":"Swimming pool water Membrane filtration method Range PN-EN ISO 11731:2017-08 +Ap1:2019-12","technique_en":"Membrane filtration method","test_object_en":"Swimming pool water","parameters_zh":[{"name":"范围","range":"od 1 jtk/100 ml"}],"search_zh":"游泳池水 膜过滤法 范围 PN-EN ISO 11731:2017-08 +Ap1:2019-12","technique_zh":"膜过滤法","test_object_zh":"游泳池水"},{"_id":"6a837436af14b9c0e7b1f3a9","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Liczba Pseudomonas aeruginosa","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009 Woda na plywalniach Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water"],"row_index":94,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Pseudomonas aeruginosa count","search_en":"Swimming pool water Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009","technique_en":"Membrane filtration method","test_object_en":"Swimming pool water","methodology_zh":"铜绿假单胞菌计数","search_zh":"游泳池水 铜绿假单胞菌计数 膜过滤法 PN-EN ISO 16266:2009","technique_zh":"膜过滤法","test_object_zh":"游泳池水"},{"_id":"6a837436af14b9c0e7b1f3aa","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda","methodology":"Ogólna liczba mikroorganizmów w 22°C","parameters":[],"technique":"Metoda płytkowa – posiew wgłębny","techniques":["Metoda płytkowa – posiew wgłębny"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w 22°C\nMetoda płytkowa – posiew wgłębny","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Ogólna liczba mikroorganizmów w 22°C\nMetoda płytkowa – posiew wgłębny PN-EN ISO 6222:2004 Woda Ogolna liczba mikroorganizmow w 22°C\nMetoda plytkowa – posiew wglebny PN-EN ISO 6222:2004","categories":["water"],"row_index":95,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total viable count at 22°C","search_en":"Water Total viable count at 22°C PN-EN ISO 6222:2004","test_object_en":"Water","methodology_zh":"22°C 微生物总数","search_zh":"水 22°C 微生物总数 PN-EN ISO 6222:2004","test_object_zh":"水"},{"_id":"6a837436af14b9c0e7b1f3ab","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda","methodology":"Ogólna liczba mikroorganizmów w 36°C","parameters":[],"technique":"Metoda płytkowa – posiew wgłębny","techniques":["Metoda płytkowa – posiew wgłębny"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w 36°C\nMetoda płytkowa – posiew wgłębny","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Ogólna liczba mikroorganizmów w 36°C\nMetoda płytkowa – posiew wgłębny PN-EN ISO 6222:2004 Woda Ogolna liczba mikroorganizmow w 36°C\nMetoda plytkowa – posiew wglebny PN-EN ISO 6222:2004","categories":["water"],"row_index":96,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total viable count at 36°C","search_en":"Water Total viable count at 36°C PN-EN ISO 6222:2004","test_object_en":"Water","methodology_zh":"36°C 微生物总数","search_zh":"水 36°C 微生物总数 PN-EN ISO 6222:2004","test_object_zh":"水"},{"_id":"6a837436af14b9c0e7b1f3ac","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda","methodology":"Liczba enterokoków kałowych","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba enterokoków kałowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Liczba enterokoków kałowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda Liczba enterokokow kalowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":97,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Intestinal enterococci count","search_en":"Water Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004","technique_en":"Membrane filtration method","test_object_en":"Water","methodology_zh":"粪肠球菌计数","search_zh":"水 粪肠球菌计数 膜过滤法 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"水"},{"_id":"6a837436af14b9c0e7b1f3ad","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda","methodology":"Liczba Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":98,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Escherichia coli count","search_en":"Water Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水"},{"_id":"6a837436af14b9c0e7b1f3ae","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda","methodology":"Liczba bakterii grupy coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":99,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Coliform bacteria count","search_en":"Water Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water","methodology_zh":"大肠菌群计数","search_zh":"水 大肠菌群计数 膜过滤法 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水"},{"_id":"6a837436af14b9c0e7b1f3af","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie manganu","parameters":[{"name":"Zakres","range":"(15 - 700) μg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie manganu\nZakres (15 - 700) μg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 8288:2002 Metoda A","norm_bases":["PN-ISO 8288:2002 Metoda A"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie manganu\nZakres (15 - 700) μg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 Metoda A Woda, Woda do spozycia przez ludzi Stezenie manganu\nZakres (15 - 700) μg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 Metoda A","categories":["water"],"row_index":100,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Manganese concentration","parameters_en":[{"name":"Range","range":"(15 - 700) μg/l"}],"search_en":"Water, Water intended for human consumption Manganese concentration Flame atomic absorption spectrometry (FAAS) Range PN-ISO 8288:2002 Metoda A","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Water, Water intended for human consumption","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(15 - 700) μg/l"}],"search_zh":"水、生活饮用水 锰浓度 火焰原子吸收光谱法（FAAS） 范围 PN-ISO 8288:2002 Metoda A","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"水、生活饮用水"},{"_id":"6a837436af14b9c0e7b1f3b0","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie żelaza","parameters":[{"name":"Zakres","range":"(50 - 5000) μg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie żelaza\nZakres (50 - 5000) μg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 8288:2002 Metoda A","norm_bases":["PN-ISO 8288:2002 Metoda A"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie żelaza\nZakres (50 - 5000) μg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 Metoda A Woda, Woda do spozycia przez ludzi Stezenie zelaza\nZakres (50 - 5000) μg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 Metoda A","categories":["water"],"row_index":101,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Iron concentration","parameters_en":[{"name":"Range","range":"(50 - 5000) μg/l"}],"search_en":"Water, Water intended for human consumption Iron concentration Flame atomic absorption spectrometry (FAAS) Range PN-ISO 8288:2002 Metoda A","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Water, Water intended for human consumption","methodology_zh":"铁浓度","parameters_zh":[{"name":"范围","range":"(50 - 5000) μg/l"}],"search_zh":"水、生活饮用水 铁浓度 火焰原子吸收光谱法（FAAS） 范围 PN-ISO 8288:2002 Metoda A","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"水、生活饮用水"},{"_id":"6a837436af14b9c0e7b1f3b1","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie trichlorometanu (chloroform)","parameters":[{"name":"Zakres","range":"(5,0 - 50) μg/l"},{"name":"Stężenie dibromochlorometanu","range":"(3,0 - 50) μg/l"},{"name":"Stężenie bromodichlorometanu","range":"(5,0 - 50) μg/l"},{"name":"Stężenie tribromometanu (bromoform)","range":"(5,0 - 50) μg/l"},{"name":"Σ THM (Σ trichlorometanu, dibromochlorometanu, bromodichlorometanu, tribromometanu) (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","techniques":["Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)"],"computed":[],"activity":"Stężenie trichlorometanu (chloroform)\nZakres:\nZakres (5,0 - 50) μg/l\nStężenie dibromochlorometanu (3,0 - 50) μg/l\nStężenie bromodichlorometanu (5,0 - 50) μg/l\nStężenie tribromometanu (bromoform) (5,0 - 50) μg/l\nΣ THM (Σ trichlorometanu, dibromochlorometanu, bromodichlorometanu, tribromometanu) (z obliczeń)\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","reference":"PN-EN ISO 10301:2002","norm_bases":["PN-EN ISO 10301:2002"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiskowych; Sekcja Badania Wody w Zduńskiej Woli","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie trichlorometanu (chloroform)\nZakres:\nZakres (5,0 - 50) μg/l\nStężenie dibromochlorometanu (3,0 - 50) μg/l\nStężenie bromodichlorometanu (5,0 - 50) μg/l\nStężenie tribromometanu (bromoform) (5,0 - 50) μg/l\nΣ THM (Σ trichlorometanu, dibromochlorometanu, bromodichlorometanu, tribromometanu) (z obliczeń)\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) PN-EN ISO 10301:2002 Woda, Woda do spozycia przez ludzi Stezenie trichlorometanu (chloroform)\nZakres:\nZakres (5,0 - 50) μg/l\nStezenie dibromochlorometanu (3,0 - 50) μg/l\nStezenie bromodichlorometanu (5,0 - 50) μg/l\nStezenie tribromometanu (bromoform) (5,0 - 50) μg/l\nΣ THM (Σ trichlorometanu, dibromochlorometanu, bromodichlorometanu, tribromometanu) (z obliczen)\nMetoda chromatografii gazowej z detekcja wychwytu elektronow (GC-ECD) PN-EN ISO 10301:2002","categories":["water"],"row_index":102,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(5,0 - 50) μg/l"},{"name":"Dibromochloromethane concentration","range":"(3,0 - 50) μg/l"},{"name":"Bromodichloromethane concentration","range":"(5,0 - 50) μg/l"},{"name":"Stężenie tribromometanu (bromoform)","range":"(5,0 - 50) μg/l"},{"name":"Σ THM (Σ trichlorometanu, dibromochlorometanu, bromodichlorometanu, tribromometanu) (z obliczeń)"}],"search_en":"Water, Water intended for human consumption Gas chromatography with electron capture detection (GC-ECD) Range Dibromochloromethane concentration Bromodichloromethane concentration PN-EN ISO 10301:2002","technique_en":"Gas chromatography with electron capture detection (GC-ECD)","test_object_en":"Water, Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(5,0 - 50) μg/l"},{"name":"Stężenie dibromochlorometanu","range":"(3,0 - 50) μg/l"},{"name":"Stężenie bromodichlorometanu","range":"(5,0 - 50) μg/l"},{"name":"Stężenie tribromometanu (bromoform)","range":"(5,0 - 50) μg/l"},{"name":"Σ THM (Σ trichlorometanu, dibromochlorometanu, bromodichlorometanu, tribromometanu) (z obliczeń)"}],"search_zh":"水、生活饮用水 气相色谱-电子捕获检测法（GC-ECD） 范围 PN-EN ISO 10301:2002","technique_zh":"气相色谱-电子捕获检测法（GC-ECD）","test_object_zh":"水、生活饮用水"},{"_id":"6a837436af14b9c0e7b1f3b2","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością","methodology":"Migracja globalna do wodnych płynów modelowych","parameters":[{"name":"metoda przez całkowite zanurzenie woda","range":"(1,0 -150) mg/dm2"},{"name":"Zakres","range":"3% kw. octowy (1,0 - 150) mg/dm2"},{"name":"10% etanol","range":"(1,0 - 150) mg/dm2"},{"name":"20% etanol","range":"(1,0 - 150) mg/dm2"},{"name":"50% etanol","range":"(1,0 - 150) mg/dm2"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Migracja globalna do wodnych płynów modelowych\nZakres:\nmetoda przez całkowite zanurzenie woda (1,0 -150) mg/dm2\nZakres 3% kw. octowy (1,0 - 150) mg/dm2\n10% etanol (1,0 - 150) mg/dm2\n20% etanol (1,0 - 150) mg/dm2\n50% etanol (1,0 - 150) mg/dm2\nMetoda wagowa","reference":"PN-EN 1186-3:2023-01","norm_bases":["PN-EN 1186-3:2023-01"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością Migracja globalna do wodnych płynów modelowych\nZakres:\nmetoda przez całkowite zanurzenie woda (1,0 -150) mg/dm2\nZakres 3% kw. octowy (1,0 - 150) mg/dm2\n10% etanol (1,0 - 150) mg/dm2\n20% etanol (1,0 - 150) mg/dm2\n50% etanol (1,0 - 150) mg/dm2\nMetoda wagowa PN-EN 1186-3:2023-01 Materialy i wyroby z tworzyw sztucznych przeznaczone do kontaktu z zywnoscia Migracja globalna do wodnych plynow modelowych\nZakres:\nmetoda przez calkowite zanurzenie woda (1,0 -150) mg/dm2\nZakres 3% kw. octowy (1,0 - 150) mg/dm2\n10% etanol (1,0 - 150) mg/dm2\n20% etanol (1,0 - 150) mg/dm2\n50% etanol (1,0 - 150) mg/dm2\nMetoda wagowa PN-EN 1186-3:2023-01","categories":["materials","water","food"],"row_index":103,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Overall migration into aqueous food simulants","parameters_en":[{"name":"total immersion method water","range":"(1,0 -150) mg/dm2"},{"name":"Range","range":"3% kw. octowy (1,0 - 150) mg/dm2"},{"name":"10% ethanol","range":"(1,0 - 150) mg/dm2"},{"name":"20% ethanol","range":"(1,0 - 150) mg/dm2"},{"name":"50% ethanol","range":"(1,0 - 150) mg/dm2"}],"search_en":"Plastic materials and articles intended to come into contact with food Overall migration into aqueous food simulants Gravimetric method total immersion method water Range 10% ethanol 20% ethanol 50% ethanol PN-EN 1186-3:2023-01","technique_en":"Gravimetric method","test_object_en":"Plastic materials and articles intended to come into contact with food","parameters_zh":[{"name":"metoda przez całkowite zanurzenie woda","range":"(1,0 -150) mg/dm2"},{"name":"范围","range":"3% kw. octowy (1,0 - 150) mg/dm2"},{"name":"10% 乙醇","range":"(1,0 - 150) mg/dm2"},{"name":"20% 乙醇","range":"(1,0 - 150) mg/dm2"},{"name":"50% 乙醇","range":"(1,0 - 150) mg/dm2"}],"search_zh":"拟与食品接触的塑料材料及制品 向水基食品模拟物的总迁移量 重量法 范围 10% 乙醇 20% 乙醇 50% 乙醇 PN-EN 1186-3:2023-01","technique_zh":"重量法","test_object_zh":"拟与食品接触的塑料材料及制品","methodology_zh":"向水基食品模拟物的总迁移量"},{"_id":"6a837436af14b9c0e7b1f3b3","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością","methodology":"Migracja globalna do wodnych płynów modelowych","parameters":[{"name":"metoda z zastosowaniem komory pomiarowej woda","range":"(1,0 -150) mg/dm2"},{"name":"Zakres","range":"3% kw. octowy (1,0 - 150) mg/dm2"},{"name":"10% etanol","range":"(1,0 - 150) mg/dm2"},{"name":"20% etanol","range":"(1,0 - 150) mg/dm2"},{"name":"50% etanol","range":"(1,0 - 150) mg/dm2"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Migracja globalna do wodnych płynów modelowych\nZakres:\nmetoda z zastosowaniem komory pomiarowej woda (1,0 -150) mg/dm2\nZakres 3% kw. octowy (1,0 - 150) mg/dm2\n10% etanol (1,0 - 150) mg/dm2\n20% etanol (1,0 - 150) mg/dm2\n50% etanol (1,0 - 150) mg/dm2\nMetoda wagowa","reference":"PN-EN 1186-3:2023-01","norm_bases":["PN-EN 1186-3:2023-01"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością Migracja globalna do wodnych płynów modelowych\nZakres:\nmetoda z zastosowaniem komory pomiarowej woda (1,0 -150) mg/dm2\nZakres 3% kw. octowy (1,0 - 150) mg/dm2\n10% etanol (1,0 - 150) mg/dm2\n20% etanol (1,0 - 150) mg/dm2\n50% etanol (1,0 - 150) mg/dm2\nMetoda wagowa PN-EN 1186-3:2023-01 Materialy i wyroby z tworzyw sztucznych przeznaczone do kontaktu z zywnoscia Migracja globalna do wodnych plynow modelowych\nZakres:\nmetoda z zastosowaniem komory pomiarowej woda (1,0 -150) mg/dm2\nZakres 3% kw. octowy (1,0 - 150) mg/dm2\n10% etanol (1,0 - 150) mg/dm2\n20% etanol (1,0 - 150) mg/dm2\n50% etanol (1,0 - 150) mg/dm2\nMetoda wagowa PN-EN 1186-3:2023-01","categories":["materials","water","food"],"row_index":104,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Overall migration into aqueous food simulants","parameters_en":[{"name":"method using a test cell water","range":"(1,0 -150) mg/dm2"},{"name":"Range","range":"3% kw. octowy (1,0 - 150) mg/dm2"},{"name":"10% ethanol","range":"(1,0 - 150) mg/dm2"},{"name":"20% ethanol","range":"(1,0 - 150) mg/dm2"},{"name":"50% ethanol","range":"(1,0 - 150) mg/dm2"}],"search_en":"Plastic materials and articles intended to come into contact with food Overall migration into aqueous food simulants Gravimetric method method using a test cell water Range 10% ethanol 20% ethanol 50% ethanol PN-EN 1186-3:2023-01","technique_en":"Gravimetric method","test_object_en":"Plastic materials and articles intended to come into contact with food","parameters_zh":[{"name":"metoda z zastosowaniem komory pomiarowej woda","range":"(1,0 -150) mg/dm2"},{"name":"范围","range":"3% kw. octowy (1,0 - 150) mg/dm2"},{"name":"10% 乙醇","range":"(1,0 - 150) mg/dm2"},{"name":"20% 乙醇","range":"(1,0 - 150) mg/dm2"},{"name":"50% 乙醇","range":"(1,0 - 150) mg/dm2"}],"search_zh":"拟与食品接触的塑料材料及制品 向水基食品模拟物的总迁移量 重量法 范围 10% 乙醇 20% 乙醇 50% 乙醇 PN-EN 1186-3:2023-01","technique_zh":"重量法","test_object_zh":"拟与食品接触的塑料材料及制品","methodology_zh":"向水基食品模拟物的总迁移量"},{"_id":"6a837436af14b9c0e7b1f3b4","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością","methodology":"Migracja globalna do wodnych płynów modelowych","parameters":[{"name":"metoda z zastosowaniem torebki woda","range":"(1,0 - 150) mg/dm2"},{"name":"Zakres","range":"3% kw. octowy (1,0 - 150) mg/dm2"},{"name":"10% etanol","range":"(1,0 - 150) mg/dm2"},{"name":"20% etanol","range":"(1,0 - 150) mg/dm2"},{"name":"50% etanol","range":"(1,0 - 150) mg/dm2"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Migracja globalna do wodnych płynów modelowych\nZakres:\nmetoda z zastosowaniem torebki woda (1,0 - 150) mg/dm2\nZakres 3% kw. octowy (1,0 - 150) mg/dm2\n10% etanol (1,0 - 150) mg/dm2\n20% etanol (1,0 - 150) mg/dm2\n50% etanol (1,0 - 150) mg/dm2\nMetoda wagowa","reference":"PN-EN 1186-3:2023-01","norm_bases":["PN-EN 1186-3:2023-01"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością Migracja globalna do wodnych płynów modelowych\nZakres:\nmetoda z zastosowaniem torebki woda (1,0 - 150) mg/dm2\nZakres 3% kw. octowy (1,0 - 150) mg/dm2\n10% etanol (1,0 - 150) mg/dm2\n20% etanol (1,0 - 150) mg/dm2\n50% etanol (1,0 - 150) mg/dm2\nMetoda wagowa PN-EN 1186-3:2023-01 Materialy i wyroby z tworzyw sztucznych przeznaczone do kontaktu z zywnoscia Migracja globalna do wodnych plynow modelowych\nZakres:\nmetoda z zastosowaniem torebki woda (1,0 - 150) mg/dm2\nZakres 3% kw. octowy (1,0 - 150) mg/dm2\n10% etanol (1,0 - 150) mg/dm2\n20% etanol (1,0 - 150) mg/dm2\n50% etanol (1,0 - 150) mg/dm2\nMetoda wagowa PN-EN 1186-3:2023-01","categories":["materials","water","food"],"row_index":105,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Overall migration into aqueous food simulants","parameters_en":[{"name":"pouch method water","range":"(1,0 - 150) mg/dm2"},{"name":"Range","range":"3% kw. octowy (1,0 - 150) mg/dm2"},{"name":"10% ethanol","range":"(1,0 - 150) mg/dm2"},{"name":"20% ethanol","range":"(1,0 - 150) mg/dm2"},{"name":"50% ethanol","range":"(1,0 - 150) mg/dm2"}],"search_en":"Plastic materials and articles intended to come into contact with food Overall migration into aqueous food simulants Gravimetric method pouch method water Range 10% ethanol 20% ethanol 50% ethanol PN-EN 1186-3:2023-01","technique_en":"Gravimetric method","test_object_en":"Plastic materials and articles intended to come into contact with food","parameters_zh":[{"name":"metoda z zastosowaniem torebki woda","range":"(1,0 - 150) mg/dm2"},{"name":"范围","range":"3% kw. octowy (1,0 - 150) mg/dm2"},{"name":"10% 乙醇","range":"(1,0 - 150) mg/dm2"},{"name":"20% 乙醇","range":"(1,0 - 150) mg/dm2"},{"name":"50% 乙醇","range":"(1,0 - 150) mg/dm2"}],"search_zh":"拟与食品接触的塑料材料及制品 向水基食品模拟物的总迁移量 重量法 范围 10% 乙醇 20% 乙醇 50% 乙醇 PN-EN 1186-3:2023-01","technique_zh":"重量法","test_object_zh":"拟与食品接触的塑料材料及制品","methodology_zh":"向水基食品模拟物的总迁移量"},{"_id":"6a837436af14b9c0e7b1f3b5","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością","methodology":"Migracja globalna do wodnych płynów modelowych","parameters":[{"name":"metoda przez napełnienie wyrobu woda","range":"(1,0 - 150) mg/dm2"},{"name":"Zakres","range":"(6,0 - 500) mg/kg"},{"name":"3% kw. octowy","range":"(1,0 - 150) mg/dm2"},{"name":"(6,0 - 500) mg/kg"},{"name":"10% etanol","range":"(1,0 - 150) mg/dm2"},{"name":"(6,0 - 500) mg/kg"},{"name":"20% etanol","range":"(1,0 - 150) mg/dm2"},{"name":"(6,0 - 500) mg/kg"},{"name":"50% etanol","range":"(1,0 - 150) mg/dm2"},{"name":"(6,0 - 500) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Migracja globalna do wodnych płynów modelowych\nZakres:\nmetoda przez napełnienie wyrobu woda (1,0 - 150) mg/dm2\nZakres (6,0 - 500) mg/kg\n3% kw. octowy (1,0 - 150) mg/dm2\n(6,0 - 500) mg/kg\n10% etanol (1,0 - 150) mg/dm2\n(6,0 - 500) mg/kg\n20% etanol (1,0 - 150) mg/dm2\n(6,0 - 500) mg/kg\n50% etanol (1,0 - 150) mg/dm2\n(6,0 - 500) mg/kg\nMetoda wagowa","reference":"PN-EN 1186-3:2023-01","norm_bases":["PN-EN 1186-3:2023-01"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością Migracja globalna do wodnych płynów modelowych\nZakres:\nmetoda przez napełnienie wyrobu woda (1,0 - 150) mg/dm2\nZakres (6,0 - 500) mg/kg\n3% kw. octowy (1,0 - 150) mg/dm2\n(6,0 - 500) mg/kg\n10% etanol (1,0 - 150) mg/dm2\n(6,0 - 500) mg/kg\n20% etanol (1,0 - 150) mg/dm2\n(6,0 - 500) mg/kg\n50% etanol (1,0 - 150) mg/dm2\n(6,0 - 500) mg/kg\nMetoda wagowa PN-EN 1186-3:2023-01 Materialy i wyroby z tworzyw sztucznych przeznaczone do kontaktu z zywnoscia Migracja globalna do wodnych plynow modelowych\nZakres:\nmetoda przez napelnienie wyrobu woda (1,0 - 150) mg/dm2\nZakres (6,0 - 500) mg/kg\n3% kw. octowy (1,0 - 150) mg/dm2\n(6,0 - 500) mg/kg\n10% etanol (1,0 - 150) mg/dm2\n(6,0 - 500) mg/kg\n20% etanol (1,0 - 150) mg/dm2\n(6,0 - 500) mg/kg\n50% etanol (1,0 - 150) mg/dm2\n(6,0 - 500) mg/kg\nMetoda wagowa PN-EN 1186-3:2023-01","categories":["materials","water","food"],"row_index":106,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Overall migration into aqueous food simulants","parameters_en":[{"name":"article filling method water","range":"(1,0 - 150) mg/dm2"},{"name":"Range","range":"(6,0 - 500) mg/kg"},{"name":"3% acetic acid","range":"(1,0 - 150) mg/dm2"},{"name":"(6,0 - 500) mg/kg"},{"name":"10% ethanol","range":"(1,0 - 150) mg/dm2"},{"name":"(6,0 - 500) mg/kg"},{"name":"20% ethanol","range":"(1,0 - 150) mg/dm2"},{"name":"(6,0 - 500) mg/kg"},{"name":"50% ethanol","range":"(1,0 - 150) mg/dm2"},{"name":"(6,0 - 500) mg/kg"}],"search_en":"Plastic materials and articles intended to come into contact with food Overall migration into aqueous food simulants Gravimetric method article filling method water Range 3% acetic acid (6,0 - 500) mg/kg 10% ethanol (6,0 - 500) mg/kg 20% ethanol (6,0 - 500) mg/kg 50% ethanol (6,0 - 500) mg/kg PN-EN 1186-3:2023-01","technique_en":"Gravimetric method","test_object_en":"Plastic materials and articles intended to come into contact with food","parameters_zh":[{"name":"metoda przez napełnienie wyrobu woda","range":"(1,0 - 150) mg/dm2"},{"name":"范围","range":"(6,0 - 500) mg/kg"},{"name":"3% kw. octowy","range":"(1,0 - 150) mg/dm2"},{"name":"(6,0 - 500) mg/kg"},{"name":"10% 乙醇","range":"(1,0 - 150) mg/dm2"},{"name":"(6,0 - 500) mg/kg"},{"name":"20% 乙醇","range":"(1,0 - 150) mg/dm2"},{"name":"(6,0 - 500) mg/kg"},{"name":"50% 乙醇","range":"(1,0 - 150) mg/dm2"},{"name":"(6,0 - 500) mg/kg"}],"search_zh":"拟与食品接触的塑料材料及制品 向水基食品模拟物的总迁移量 重量法 范围 10% 乙醇 20% 乙醇 50% 乙醇 PN-EN 1186-3:2023-01","technique_zh":"重量法","test_object_zh":"拟与食品接触的塑料材料及制品","methodology_zh":"向水基食品模拟物的总迁移量"},{"_id":"6a837436af14b9c0e7b1f3b6","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością","methodology":"Migracja globalna do mediów substytucyjnych","parameters":[{"name":"izooktan","range":"(1,0 - 150,0) mg/dm2"},{"name":"Zakres","range":"(6,0 - 500,0) mg/kg"},{"name":"95% etanol","range":"(1,0 - 150,0) mg/dm2"},{"name":"(6,0 - 500,0) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Migracja globalna do mediów substytucyjnych\nZakres:\nizooktan (1,0 - 150,0) mg/dm2\nZakres (6,0 - 500,0) mg/kg\n95% etanol (1,0 - 150,0) mg/dm2\n(6,0 - 500,0) mg/kg\nMetoda wagowa","reference":"PN-EN 1186-3:2023-01","norm_bases":["PN-EN 1186-3:2023-01"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością Migracja globalna do mediów substytucyjnych\nZakres:\nizooktan (1,0 - 150,0) mg/dm2\nZakres (6,0 - 500,0) mg/kg\n95% etanol (1,0 - 150,0) mg/dm2\n(6,0 - 500,0) mg/kg\nMetoda wagowa PN-EN 1186-3:2023-01 Materialy i wyroby z tworzyw sztucznych przeznaczone do kontaktu z zywnoscia Migracja globalna do mediow substytucyjnych\nZakres:\nizooktan (1,0 - 150,0) mg/dm2\nZakres (6,0 - 500,0) mg/kg\n95% etanol (1,0 - 150,0) mg/dm2\n(6,0 - 500,0) mg/kg\nMetoda wagowa PN-EN 1186-3:2023-01","categories":["materials","food"],"row_index":107,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Overall migration into substitute media","parameters_en":[{"name":"isooctane","range":"(1,0 - 150,0) mg/dm2"},{"name":"Range","range":"(6,0 - 500,0) mg/kg"},{"name":"95% ethanol","range":"(1,0 - 150,0) mg/dm2"},{"name":"(6,0 - 500,0) mg/kg"}],"search_en":"Plastic materials and articles intended to come into contact with food Overall migration into substitute media Gravimetric method isooctane Range 95% ethanol (6,0 - 500,0) mg/kg PN-EN 1186-3:2023-01","technique_en":"Gravimetric method","test_object_en":"Plastic materials and articles intended to come into contact with food","parameters_zh":[{"name":"异辛烷","range":"(1,0 - 150,0) mg/dm2"},{"name":"范围","range":"(6,0 - 500,0) mg/kg"},{"name":"95% 乙醇","range":"(1,0 - 150,0) mg/dm2"},{"name":"(6,0 - 500,0) mg/kg"}],"search_zh":"拟与食品接触的塑料材料及制品 向替代介质的总迁移量 重量法 异辛烷 范围 95% 乙醇 PN-EN 1186-3:2023-01","technique_zh":"重量法","test_object_zh":"拟与食品接触的塑料材料及制品","methodology_zh":"向替代介质的总迁移量"},{"_id":"6a837436af14b9c0e7b1f3b7","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością","methodology":"Migracja formaldehydu do płynów modelowych","parameters":[{"name":"Zakres","range":"3% kw. octowy (1,5 - 30,0) mg/kg"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Migracja formaldehydu do płynów modelowych\nZakres 3% kw. octowy (1,5 - 30,0) mg/kg\nMetoda spektrofotometryczna","reference":"CEN/TS 13130-23: 2005","norm_bases":["CEN/TS 13130-23: 2005"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością Migracja formaldehydu do płynów modelowych\nZakres 3% kw. octowy (1,5 - 30,0) mg/kg\nMetoda spektrofotometryczna CEN/TS 13130-23: 2005 Materialy i wyroby z tworzyw sztucznych przeznaczone do kontaktu z zywnoscia Migracja formaldehydu do plynow modelowych\nZakres 3% kw. octowy (1,5 - 30,0) mg/kg\nMetoda spektrofotometryczna CEN/TS 13130-23: 2005","categories":["materials","food"],"row_index":108,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Formaldehyde migration into food simulants","parameters_en":[{"name":"Range","range":"3% kw. octowy (1,5 - 30,0) mg/kg"}],"search_en":"Plastic materials and articles intended to come into contact with food Formaldehyde migration into food simulants Spectrophotometric method Range CEN/TS 13130-23: 2005","technique_en":"Spectrophotometric method","test_object_en":"Plastic materials and articles intended to come into contact with food","parameters_zh":[{"name":"范围","range":"3% kw. octowy (1,5 - 30,0) mg/kg"}],"search_zh":"拟与食品接触的塑料材料及制品 甲醛向食品模拟物的迁移量 分光光度法 范围 CEN/TS 13130-23: 2005","technique_zh":"分光光度法","test_object_zh":"拟与食品接触的塑料材料及制品","methodology_zh":"甲醛向食品模拟物的迁移量"},{"_id":"6a837436af14b9c0e7b1f3b8","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością","methodology":"Migracja pierwszorzędowych amin aromatycznych (PAA) do płynów modelowych – 3% kw. octowy","parameters":[{"name":"Zakres","range":"2,4-TDA (0,002 - 0,03) mg/kg"},{"name":"2,6-TDA","range":"(0,002 - 0,03) mg/kg"},{"name":"Anilina","range":"(0,002 - 0,03) mg/kg"},{"name":"4,4-MDA","range":"(0,002 - 0,03) mg/kg"},{"name":"1,3 - fenylenodiamina","range":"(0,002 – 0,03) mg/kg"},{"name":"1,5 - diaminonaftalen","range":"(0,002 – 0,03) mg/kg"},{"name":"4,4 - oksydianilina","range":"(0,002 – 0,03) mg/kg"},{"name":"3,3 - dimetylobenzydyna","range":"(0,002 – 0,03) mg/kg"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC – DAD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC – DAD)"],"computed":[],"activity":"Migracja pierwszorzędowych amin aromatycznych (PAA) do płynów modelowych – 3% kw. octowy\nZakres:\nZakres 2,4-TDA (0,002 - 0,03) mg/kg\n2,6-TDA (0,002 - 0,03) mg/kg\nAnilina (0,002 - 0,03) mg/kg\n4,4-MDA (0,002 - 0,03) mg/kg\n1,3 - fenylenodiamina (0,002 – 0,03) mg/kg\n1,5 - diaminonaftalen (0,002 – 0,03) mg/kg\n4,4 - oksydianilina (0,002 – 0,03) mg/kg\n3,3 - dimetylobenzydyna (0,002 – 0,03) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC – DAD)","reference":"PB/L-84 wyd. 3 z dnia 10.01.2024 r.","norm_bases":["PB/L-84 wyd. 3 z dnia 10.01.2024 r."],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością Migracja pierwszorzędowych amin aromatycznych (PAA) do płynów modelowych – 3% kw. octowy\nZakres:\nZakres 2,4-TDA (0,002 - 0,03) mg/kg\n2,6-TDA (0,002 - 0,03) mg/kg\nAnilina (0,002 - 0,03) mg/kg\n4,4-MDA (0,002 - 0,03) mg/kg\n1,3 - fenylenodiamina (0,002 – 0,03) mg/kg\n1,5 - diaminonaftalen (0,002 – 0,03) mg/kg\n4,4 - oksydianilina (0,002 – 0,03) mg/kg\n3,3 - dimetylobenzydyna (0,002 – 0,03) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC – DAD) PB/L-84 wyd. 3 z dnia 10.01.2024 r. Materialy i wyroby z tworzyw sztucznych przeznaczone do kontaktu z zywnoscia Migracja pierwszorzedowych amin aromatycznych (PAA) do plynow modelowych – 3% kw. octowy\nZakres:\nZakres 2,4-TDA (0,002 - 0,03) mg/kg\n2,6-TDA (0,002 - 0,03) mg/kg\nAnilina (0,002 - 0,03) mg/kg\n4,4-MDA (0,002 - 0,03) mg/kg\n1,3 - fenylenodiamina (0,002 – 0,03) mg/kg\n1,5 - diaminonaftalen (0,002 – 0,03) mg/kg\n4,4 - oksydianilina (0,002 – 0,03) mg/kg\n3,3 - dimetylobenzydyna (0,002 – 0,03) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcja matryca diodowa (HPLC – DAD) PB/L-84 wyd. 3 z dnia 10.01.2024 r.","categories":["materials","food"],"row_index":109,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Migration of primary aromatic amines (PAA) into food simulants – 3% acetic acid","parameters_en":[{"name":"Range","range":"2,4-TDA (0,002 - 0,03) mg/kg"},{"name":"2,6-TDA","range":"(0,002 - 0,03) mg/kg"},{"name":"Aniline","range":"(0,002 - 0,03) mg/kg"},{"name":"4,4-MDA","range":"(0,002 - 0,03) mg/kg"},{"name":"1,3 - phenylenediamine","range":"(0,002 – 0,03) mg/kg"},{"name":"1,5 - diaminonaphthalene","range":"(0,002 – 0,03) mg/kg"},{"name":"4,4 - oxydianiline","range":"(0,002 – 0,03) mg/kg"},{"name":"3,3 - dimethylbenzidine","range":"(0,002 – 0,03) mg/kg"}],"search_en":"Plastic materials and articles intended to come into contact with food Migration of primary aromatic amines (PAA) into food simulants – 3% acetic acid High-performance liquid chromatography with diode array detection (HPLC – DAD) Range 2,6-TDA Aniline 4,4-MDA 1,3 - phenylenediamine 1,5 - diaminonaphthalene 4,4 - oxydianiline 3,3 - dimethylbenzidine PB/L-84 wyd. 3 z dnia 10.01.2024 r.","technique_en":"High-performance liquid chromatography with diode array detection (HPLC – DAD)","test_object_en":"Plastic materials and articles intended to come into contact with food","parameters_zh":[{"name":"范围","range":"2,4-TDA (0,002 - 0,03) mg/kg"},{"name":"2,6-TDA","range":"(0,002 - 0,03) mg/kg"},{"name":"Anilina","range":"(0,002 - 0,03) mg/kg"},{"name":"4,4-MDA","range":"(0,002 - 0,03) mg/kg"},{"name":"1,3 - fenylenodiamina","range":"(0,002 – 0,03) mg/kg"},{"name":"1,5 - diaminonaftalen","range":"(0,002 – 0,03) mg/kg"},{"name":"4,4 - oksydianilina","range":"(0,002 – 0,03) mg/kg"},{"name":"3,3 - dimetylobenzydyna","range":"(0,002 – 0,03) mg/kg"}],"search_zh":"拟与食品接触的塑料材料及制品 高效液相色谱-二极管阵列检测法（HPLC – DAD） 范围 PB/L-84 wyd. 3 z dnia 10.01.2024 r.","test_object_zh":"拟与食品接触的塑料材料及制品","technique_zh":"高效液相色谱-二极管阵列检测法（HPLC – DAD）"},{"_id":"6a837436af14b9c0e7b1f3b9","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością","methodology":"Migracja bisfenolu A","parameters":[{"name":"Zakres","range":"(0,01 - 0,1) mg/kg"}],"technique":"Metoda chromatografii cieczowej z detekcją fluorescencyjną (HPLC – FLD)","techniques":["Metoda chromatografii cieczowej z detekcją fluorescencyjną (HPLC – FLD)"],"computed":[],"activity":"Migracja bisfenolu A\nZakres (0,01 - 0,1) mg/kg\nMetoda chromatografii cieczowej z detekcją fluorescencyjną (HPLC – FLD)","reference":"PB/L-108 wyd. 1 z dnia 05.09.2022r.","norm_bases":["PB/L-108 wyd. 1 z dnia 05.09.2022r."],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością Migracja bisfenolu A\nZakres (0,01 - 0,1) mg/kg\nMetoda chromatografii cieczowej z detekcją fluorescencyjną (HPLC – FLD) PB/L-108 wyd. 1 z dnia 05.09.2022r. Materialy i wyroby z tworzyw sztucznych przeznaczone do kontaktu z zywnoscia Migracja bisfenolu A\nZakres (0,01 - 0,1) mg/kg\nMetoda chromatografii cieczowej z detekcja fluorescencyjna (HPLC – FLD) PB/L-108 wyd. 1 z dnia 05.09.2022r.","categories":["materials","food"],"row_index":110,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Migration of bisphenol A","parameters_en":[{"name":"Range","range":"(0,01 - 0,1) mg/kg"}],"search_en":"Plastic materials and articles intended to come into contact with food Migration of bisphenol A Liquid chromatography with fluorescence detection (HPLC – FLD) Range PB/L-108 wyd. 1 z dnia 05.09.2022r.","technique_en":"Liquid chromatography with fluorescence detection (HPLC – FLD)","test_object_en":"Plastic materials and articles intended to come into contact with food","parameters_zh":[{"name":"范围","range":"(0,01 - 0,1) mg/kg"}],"search_zh":"拟与食品接触的塑料材料及制品 范围 PB/L-108 wyd. 1 z dnia 05.09.2022r.","test_object_zh":"拟与食品接触的塑料材料及制品"},{"_id":"6a837436af14b9c0e7b1f3ba","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Papier i tektura przeznaczone do kontaktu z żywnością","methodology":"Zawartość formaldehydu w wyciągu wodnym","parameters":[{"name":"Zakres","range":"(1 – 25) mg/kg"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość formaldehydu w wyciągu wodnym\nZakres (1 – 25) mg/kg\nMetoda spektrofotometryczna","reference":"PN-EN 1541:2003","norm_bases":["PN-EN 1541:2003"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Papier i tektura przeznaczone do kontaktu z żywnością Zawartość formaldehydu w wyciągu wodnym\nZakres (1 – 25) mg/kg\nMetoda spektrofotometryczna PN-EN 1541:2003 Papier i tektura przeznaczone do kontaktu z zywnoscia Zawartosc formaldehydu w wyciagu wodnym\nZakres (1 – 25) mg/kg\nMetoda spektrofotometryczna PN-EN 1541:2003","categories":["food"],"row_index":111,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Formaldehyde content in the water extract","parameters_en":[{"name":"Range","range":"(1 – 25) mg/kg"}],"search_en":"Paper and paperboard intended to come into contact with food Formaldehyde content in the water extract Spectrophotometric method Range PN-EN 1541:2003","technique_en":"Spectrophotometric method","test_object_en":"Paper and paperboard intended to come into contact with food","parameters_zh":[{"name":"范围","range":"(1 – 25) mg/kg"}],"search_zh":"拟与食品接触的纸与纸板 水浸出液中的甲醛含量 分光光度法 范围 PN-EN 1541:2003","technique_zh":"分光光度法","methodology_zh":"水浸出液中的甲醛含量","test_object_zh":"拟与食品接触的纸与纸板"},{"_id":"6a837436af14b9c0e7b1f3bb","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Papier i tektura przeznaczone do kontaktu z żywnością","methodology":"Zawartość niezwiązanego fenolu w wyciągu wodnym","parameters":[{"name":"Zakres","range":"(0,25 – 25) mg/kg"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość niezwiązanego fenolu w wyciągu wodnym\nZakres (0,25 – 25) mg/kg\nMetoda spektrofotometryczna","reference":"PN-P-50430:1998 załącznik D","norm_bases":["PN-P-50430:1998 załącznik D"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Papier i tektura przeznaczone do kontaktu z żywnością Zawartość niezwiązanego fenolu w wyciągu wodnym\nZakres (0,25 – 25) mg/kg\nMetoda spektrofotometryczna PN-P-50430:1998 załącznik D Papier i tektura przeznaczone do kontaktu z zywnoscia Zawartosc niezwiazanego fenolu w wyciagu wodnym\nZakres (0,25 – 25) mg/kg\nMetoda spektrofotometryczna PN-P-50430:1998 zalacznik D","categories":["food"],"row_index":112,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of unbound phenol in the water extract","parameters_en":[{"name":"Range","range":"(0,25 – 25) mg/kg"}],"search_en":"Paper and paperboard intended to come into contact with food Content of unbound phenol in the water extract Spectrophotometric method Range PN-P-50430:1998 załącznik D","technique_en":"Spectrophotometric method","test_object_en":"Paper and paperboard intended to come into contact with food","parameters_zh":[{"name":"范围","range":"(0,25 – 25) mg/kg"}],"search_zh":"拟与食品接触的纸与纸板 分光光度法 范围 PN-P-50430:1998 załącznik D","technique_zh":"分光光度法","test_object_zh":"拟与食品接触的纸与纸板"},{"_id":"6a837436af14b9c0e7b1f3bc","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Produkty kosmetyczne","methodology":"Zawartość formaldehydu","parameters":[{"name":"Zakres","range":"(0,002 - 0,05) %"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość formaldehydu\nZakres (0,002 - 0,05) %\nMetoda spektrofotometryczna","reference":"Rozporządzenie Ministra Zdrowia z dnia 19 marca 2020 r. (Dz. U. z dnia 26 maja 2020r., poz. 931) Zał. punkt XI","norm_bases":["Rozporządzenie Ministra Zdrowia z dnia 19 marca 2020 r. (Dz. U. z dnia 26 maja 2020r., poz. 931) Zał. punkt XI"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Produkty kosmetyczne Zawartość formaldehydu\nZakres (0,002 - 0,05) %\nMetoda spektrofotometryczna Rozporządzenie Ministra Zdrowia z dnia 19 marca 2020 r. (Dz. U. z dnia 26 maja 2020r., poz. 931) Zał. punkt XI Produkty kosmetyczne Zawartosc formaldehydu\nZakres (0,002 - 0,05) %\nMetoda spektrofotometryczna Rozporzadzenie Ministra Zdrowia z dnia 19 marca 2020 r. (Dz. U. z dnia 26 maja 2020r., poz. 931) Zal. punkt XI","categories":["other"],"row_index":113,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Formaldehyde content","parameters_en":[{"name":"Range","range":"(0,002 - 0,05) %"}],"search_en":"Cosmetic products Formaldehyde content Spectrophotometric method Range Rozporządzenie Ministra Zdrowia z dnia 19 marca 2020 r. (Dz. U. z dnia 26 maja 2020r., poz. 931) Zał. punkt XI","technique_en":"Spectrophotometric method","test_object_en":"Cosmetic products","parameters_zh":[{"name":"范围","range":"(0,002 - 0,05) %"}],"search_zh":"化妆品 甲醛含量 分光光度法 范围 Rozporządzenie Ministra Zdrowia z dnia 19 marca 2020 r. (Dz. U. z dnia 26 maja 2020r., poz. 931) Zał. punkt XI","technique_zh":"分光光度法","methodology_zh":"甲醛含量","test_object_zh":"化妆品"},{"_id":"6a837436af14b9c0e7b1f3bd","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Produkty kosmetyczne","methodology":"Zawartość azotynów","parameters":[{"name":"Zakres","range":"(0,04 - 0,20)%"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość azotynów\nZakres (0,04 - 0,20)%\nMetoda spektrofotometryczna","reference":"Rozporządzenie Ministra Zdrowia z dnia 19 marca 2020 r. (Dz. U. z dnia 26 maja 2020r., poz. 931) Zał. punkt X","norm_bases":["Rozporządzenie Ministra Zdrowia z dnia 19 marca 2020 r. (Dz. U. z dnia 26 maja 2020r., poz. 931) Zał. punkt X"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badania Żywności i Produktów Kosmetycznych; Pracownia Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Produkty kosmetyczne Zawartość azotynów\nZakres (0,04 - 0,20)%\nMetoda spektrofotometryczna Rozporządzenie Ministra Zdrowia z dnia 19 marca 2020 r. (Dz. U. z dnia 26 maja 2020r., poz. 931) Zał. punkt X Produkty kosmetyczne Zawartosc azotynow\nZakres (0,04 - 0,20)%\nMetoda spektrofotometryczna Rozporzadzenie Ministra Zdrowia z dnia 19 marca 2020 r. (Dz. U. z dnia 26 maja 2020r., poz. 931) Zal. punkt X","categories":["other"],"row_index":114,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite content","parameters_en":[{"name":"Range","range":"(0,04 - 0,20)%"}],"search_en":"Cosmetic products Nitrite content Spectrophotometric method Range Rozporządzenie Ministra Zdrowia z dnia 19 marca 2020 r. (Dz. U. z dnia 26 maja 2020r., poz. 931) Zał. punkt X","technique_en":"Spectrophotometric method","test_object_en":"Cosmetic products","parameters_zh":[{"name":"范围","range":"(0,04 - 0,20)%"}],"search_zh":"化妆品 亚硝酸盐含量 分光光度法 范围 Rozporządzenie Ministra Zdrowia z dnia 19 marca 2020 r. (Dz. U. z dnia 26 maja 2020r., poz. 931) Zał. punkt X","technique_zh":"分光光度法","methodology_zh":"亚硝酸盐含量","test_object_zh":"化妆品"},{"_id":"6a837436af14b9c0e7b1f3be","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Środowisko pracy - hałas","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(44 – 136) dB"},{"name":"Szczytowy poziom dźwięku C","range":"(50 – 140) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (44 – 136) dB\nSzczytowy poziom dźwięku C (50 – 140) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 | PN-EN ISO 9612: 2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612: 2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań i Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (44 – 136) dB\nSzczytowy poziom dźwięku C (50 – 140) dB\nMetoda pomiarowa bezpośrednia PN-N-01307:1994 | PN-EN ISO 9612: 2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11 Srodowisko pracy - halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A\nZakres:\nZakres (44 – 136) dB\nSzczytowy poziom dzwieku C (50 – 140) dB\nMetoda pomiarowa bezposrednia PN-N-01307:1994 | PN-EN ISO 9612: 2011 z wylaczeniem metody obejmujacej strategie 2 i 3 – punkt 10 i 11","categories":["environment"],"row_index":115,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound level Maximum A-weighted sound level","parameters_en":[{"name":"Range","range":"(44 – 136) dB"},{"name":"C-weighted peak sound pressure level","range":"(50 – 140) dB"}],"search_en":"Workplace environment - noise A-weighted equivalent sound level Maximum A-weighted sound level Direct measurement method Range C-weighted peak sound pressure level PN-N-01307:1994 | PN-EN ISO 9612: 2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11","technique_en":"Direct measurement method","test_object_en":"Workplace environment - noise","methodology_zh":"A 计权等效声级 A 计权最大声级","parameters_zh":[{"name":"范围","range":"(44 – 136) dB"},{"name":"C 计权峰值声级","range":"(50 – 140) dB"}],"search_zh":"工作场所环境 — 噪声 A 计权等效声级 A 计权最大声级 直接测量法 范围 C 计权峰值声级 PN-N-01307:1994 | PN-EN ISO 9612: 2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a837436af14b9c0e7b1f3bf","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Środowisko pracy - hałas","methodology":"Poziom ekspozycji na hałas odniesiony do:","parameters":[{"name":"8-godzinnego dobowego wymiaru czasu pracy"},{"name":"tygodnia pracy (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godzinnego dobowego wymiaru czasu pracy\ntygodnia pracy (z obliczeń)","reference":"PN-N-01307:1994 | PN-EN ISO 9612: 2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612: 2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań i Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - hałas Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godzinnego dobowego wymiaru czasu pracy\ntygodnia pracy (z obliczeń) PN-N-01307:1994 | PN-EN ISO 9612: 2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11 Srodowisko pracy - halas Poziom ekspozycji na halas odniesiony do:\nZakres:\n8-godzinnego dobowego wymiaru czasu pracy\ntygodnia pracy (z obliczen) PN-N-01307:1994 | PN-EN ISO 9612: 2011 z wylaczeniem metody obejmujacej strategie 2 i 3 – punkt 10 i 11","categories":["environment"],"row_index":116,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Noise exposure level referred to:","parameters_en":[{"name":"an 8-hour daily working time"},{"name":"the working week (calculated)"}],"search_en":"Workplace environment - noise Noise exposure level referred to: an 8-hour daily working time the working week (calculated) PN-N-01307:1994 | PN-EN ISO 9612: 2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11","test_object_en":"Workplace environment - noise","methodology_zh":"噪声暴露级，参照：","search_zh":"工作场所环境 — 噪声 噪声暴露级，参照： 8 小时日工作时间 工作周（由计算得出） PN-N-01307:1994 | PN-EN ISO 9612: 2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11","test_object_zh":"工作场所环境 — 噪声","parameters_zh":[{"name":"8 小时日工作时间"},{"name":"工作周（由计算得出）"}]},{"_id":"6a837436af14b9c0e7b1f3c0","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Środowisko pracy - drgania działające na organizm człowieka przez kończyny górne","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","parameters":[{"name":"Zakres","range":"(0,06 – 200) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,06 – 200) m/s2\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-2:2004/A1:2015-11"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań i Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - drgania działające na organizm człowieka przez kończyny górne Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,06 – 200) m/s2\nMetoda pomiarowa bezpośrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 Srodowisko pracy - drgania dzialajace na organizm czlowieka przez konczyny gorne Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres (0,06 – 200) m/s2\nMetoda pomiarowa bezposrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","categories":["environment"],"row_index":117,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Frequency-weighted r.m.s. vibration acceleration","parameters_en":[{"name":"Range","range":"(0,06 – 200) m/s2"}],"search_en":"Workplace environment - hand-arm vibration Frequency-weighted r.m.s. vibration acceleration Direct measurement method Range PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","technique_en":"Direct measurement method","test_object_en":"Workplace environment - hand-arm vibration","methodology_zh":"频率计权振动加速度有效值","parameters_zh":[{"name":"范围","range":"(0,06 – 200) m/s2"}],"search_zh":"工作场所环境 — 手传振动 频率计权振动加速度有效值 直接测量法 范围 PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 手传振动"},{"_id":"6a837436af14b9c0e7b1f3c1","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Środowisko pracy - drgania działające na organizm człowieka przez kończyny górne","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-2:2004/A1:2015-11"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań i Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - drgania działające na organizm człowieka przez kończyny górne Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 Srodowisko pracy - drgania dzialajace na organizm czlowieka przez konczyny gorne Ekspozycja dzienna, wyrazona w postaci rownowaznej energetycznie dla 8-godzin dzialania sumy wektorowej skutecznych, skorygowanych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci sumy wektorowej skutecznych, wazonych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz) (z obliczen) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","categories":["environment"],"row_index":118,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated)","search_en":"Workplace environment - hand-arm vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","test_object_en":"Workplace environment - hand-arm vibration","methodology_zh":"日暴露量，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值矢量和的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值的矢量和表示（计算值）","search_zh":"工作场所环境 — 手传振动 日暴露量，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值矢量和的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值的矢量和表示（计算值） PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","test_object_zh":"工作场所环境 — 手传振动"},{"_id":"6a837436af14b9c0e7b1f3c2","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","parameters":[{"name":"Zakres","range":"(0,01– 157) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,01– 157) m/s2\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań i Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,01– 157) m/s2\nMetoda pomiarowa bezpośrednia PN-EN 14253+A1:2011 Srodowisko pracy – drgania o ogolnym dzialaniu na organizm czlowieka Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres (0,01– 157) m/s2\nMetoda pomiarowa bezposrednia PN-EN 14253+A1:2011","categories":["environment"],"row_index":119,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Frequency-weighted r.m.s. vibration acceleration","parameters_en":[{"name":"Range","range":"(0,01– 157) m/s2"}],"search_en":"Workplace environment – whole-body vibration Frequency-weighted r.m.s. vibration acceleration Direct measurement method Range PN-EN 14253+A1:2011","technique_en":"Direct measurement method","test_object_en":"Workplace environment – whole-body vibration","methodology_zh":"频率计权振动加速度有效值","parameters_zh":[{"name":"范围","range":"(0,01– 157) m/s2"}],"search_zh":"工作场所环境 — 全身振动 频率计权振动加速度有效值 直接测量法 范围 PN-EN 14253+A1:2011","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 全身振动"},{"_id":"6a837436af14b9c0e7b1f3c3","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz) (z obliczeń)","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań i Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz) (z obliczeń) PN-EN 14253+A1:2011 Srodowisko pracy – drgania o ogolnym dzialaniu na organizm czlowieka Ekspozycja dzienna, wyrazona w postaci rownowaznego energetycznie dla 8-godzin dzialania skutecznego, skorygowanego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1,4awx, 1,4awy, awz), Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci skutecznego, wazonego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1,4awx, 1,4awy, awz) (z obliczen) PN-EN 14253+A1:2011","categories":["environment"],"row_index":120,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1,4awx, 1,4awy, awz), Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1,4awx, 1,4awy, awz) (calculated)","search_en":"Workplace environment – whole-body vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1,4awx, 1,4awy, awz), Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1,4awx, 1,4awy, awz) (calculated) PN-EN 14253+A1:2011","test_object_en":"Workplace environment – whole-body vibration","search_zh":"工作场所环境 — 全身振动 日暴露量，以考虑相应系数后三个方向分量（1,4awx、1,4awy、awz）所测定的振动加速度中占主导的频率计权有效振动加速度的8小时能量等效值表示；持续30分钟及以下的暴露量，以考虑相应系数后三个方向分量（1,4awx、1,4awy、awz）所测定的振动加速度中占主导的频率计权有效振动加速度表示（由计算得出） PN-EN 14253+A1:2011","test_object_zh":"工作场所环境 — 全身振动","methodology_zh":"日暴露量，以考虑相应系数后三个方向分量（1,4awx、1,4awy、awz）所测定的振动加速度中占主导的频率计权有效振动加速度的8小时能量等效值表示；持续30分钟及以下的暴露量，以考虑相应系数后三个方向分量（1,4awx、1,4awy、awz）所测定的振动加速度中占主导的频率计权有效振动加速度表示（由计算得出）"},{"_id":"6a837436af14b9c0e7b1f3c4","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie elektryczne","methodology":"Natężenie oświetlenia","parameters":[{"name":"Zakres","range":"(5 – 10 000) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie oświetlenia\nZakres (5 – 10 000) lx\nMetoda pomiarowa bezpośrednia","reference":"PN-83/E-04040.03","norm_bases":["PN-83/E-04040.03"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań i Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie elektryczne Natężenie oświetlenia\nZakres (5 – 10 000) lx\nMetoda pomiarowa bezpośrednia PN-83/E-04040.03 Srodowisko pracy - oswietlenie elektryczne Natezenie oswietlenia\nZakres (5 – 10 000) lx\nMetoda pomiarowa bezposrednia PN-83/E-04040.03","categories":["environment"],"row_index":121,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance","parameters_en":[{"name":"Range","range":"(5 – 10 000) lx"}],"search_en":"Workplace environment - electric lighting Illuminance Direct measurement method Range PN-83/E-04040.03","technique_en":"Direct measurement method","test_object_en":"Workplace environment - electric lighting","methodology_zh":"照度","parameters_zh":[{"name":"范围","range":"(5 – 10 000) lx"}],"search_zh":"工作环境 － 电气照明 照度 直接测量法 范围 PN-83/E-04040.03","technique_zh":"直接测量法","test_object_zh":"工作环境 － 电气照明"},{"_id":"6a837436af14b9c0e7b1f3c5","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie elektryczne","methodology":"Równomierność oświetlenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równomierność oświetlenia (z obliczeń)","reference":"PN-83/E-04040.03","norm_bases":["PN-83/E-04040.03"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań i Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie elektryczne Równomierność oświetlenia (z obliczeń) PN-83/E-04040.03 Srodowisko pracy - oswietlenie elektryczne Rownomiernosc oswietlenia (z obliczen) PN-83/E-04040.03","categories":["environment"],"row_index":122,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance uniformity (calculated)","search_en":"Workplace environment - electric lighting Illuminance uniformity (calculated) PN-83/E-04040.03","test_object_en":"Workplace environment - electric lighting","methodology_zh":"照度均匀度（计算值）","search_zh":"工作环境 － 电气照明 照度均匀度（计算值） PN-83/E-04040.03","test_object_zh":"工作环境 － 电气照明"},{"_id":"6a837436af14b9c0e7b1f3c6","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat zimny","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(-20 – 10) °C"},{"name":"Temperatura poczernionej kuli","range":"(-20 – 15) °C"},{"name":"Wilgotność powietrza","range":"(25 – 80) %"},{"name":"Prędkość powietrza","range":"(0,15 – 5,0) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (-20 – 10) °C\nTemperatura poczernionej kuli (-20 – 15) °C\nWilgotność powietrza (25 – 80) %\nPrędkość powietrza (0,15 – 5,0) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 11079:2008","norm_bases":["PN-EN ISO 11079:2008"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań i Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat zimny Temperatura powietrza\nZakres:\nZakres (-20 – 10) °C\nTemperatura poczernionej kuli (-20 – 15) °C\nWilgotność powietrza (25 – 80) %\nPrędkość powietrza (0,15 – 5,0) m/s\nMetoda pomiarowa bezpośrednia PN-EN ISO 11079:2008 Srodowisko pracy - mikroklimat zimny Temperatura powietrza\nZakres:\nZakres (-20 – 10) °C\nTemperatura poczernionej kuli (-20 – 15) °C\nWilgotnosc powietrza (25 – 80) %\nPredkosc powietrza (0,15 – 5,0) m/s\nMetoda pomiarowa bezposrednia PN-EN ISO 11079:2008","categories":["environment"],"row_index":123,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(-20 – 10) °C"},{"name":"Black globe temperature","range":"(-20 – 15) °C"},{"name":"Air humidity","range":"(25 – 80) %"},{"name":"Air velocity","range":"(0,15 – 5,0) m/s"}],"search_en":"Workplace environment - cold microclimate Air temperature Direct measurement method Range Black globe temperature Air humidity Air velocity PN-EN ISO 11079:2008","technique_en":"Direct measurement method","test_object_en":"Workplace environment - cold microclimate","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(-20 – 10) °C"},{"name":"黑球温度","range":"(-20 – 15) °C"},{"name":"空气湿度","range":"(25 – 80) %"},{"name":"空气流速","range":"(0,15 – 5,0) m/s"}],"search_zh":"工作场所环境 — 低温微气候 空气温度 直接测量法 范围 黑球温度 空气湿度 空气流速 PN-EN ISO 11079:2008","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 低温微气候"},{"_id":"6a837436af14b9c0e7b1f3c7","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat zimny","methodology":"Wskaźnik IREQmin, Wskaźnik IREQneutral, Wskaźnik twc (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik IREQmin, Wskaźnik IREQneutral, Wskaźnik twc (z obliczeń)","reference":"PN-EN ISO 11079:2008","norm_bases":["PN-EN ISO 11079:2008"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań i Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat zimny Wskaźnik IREQmin, Wskaźnik IREQneutral, Wskaźnik twc (z obliczeń) PN-EN ISO 11079:2008 Srodowisko pracy - mikroklimat zimny Wskaznik IREQmin, Wskaznik IREQneutral, Wskaznik twc (z obliczen) PN-EN ISO 11079:2008","categories":["environment"],"row_index":124,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"IREQmin index, IREQneutral index, twc index (calculated)","search_en":"Workplace environment - cold microclimate IREQmin index, IREQneutral index, twc index (calculated) PN-EN ISO 11079:2008","test_object_en":"Workplace environment - cold microclimate","search_zh":"工作场所环境 — 低温微气候 IREQmin 指数、IREQneutral 指数、twc 指数（计算值） PN-EN ISO 11079:2008","test_object_zh":"工作场所环境 — 低温微气候","methodology_zh":"IREQmin 指数、IREQneutral 指数、twc 指数（计算值）"},{"_id":"6a837436af14b9c0e7b1f3c8","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat gorący","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(15 – 50) °C"},{"name":"Temperatura wilgotna naturalna","range":"(15 – 50) °C"},{"name":"Temperatura poczernionej kuli","range":"(15 – 60) °C"},{"name":"Prędkość powietrza","range":"(0,15 – 5,0) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (15 – 50) °C\nTemperatura wilgotna naturalna (15 – 50) °C\nTemperatura poczernionej kuli (15 – 60) °C\nPrędkość powietrza (0,15 – 5,0) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020-04","norm_bases":["PN-EN ISO 7243:2018-01","PN-EN ISO 7243:2018-01/Ap2:2020-04"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań i Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat gorący Temperatura powietrza\nZakres:\nZakres (15 – 50) °C\nTemperatura wilgotna naturalna (15 – 50) °C\nTemperatura poczernionej kuli (15 – 60) °C\nPrędkość powietrza (0,15 – 5,0) m/s\nMetoda pomiarowa bezpośrednia PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020-04 Srodowisko pracy - mikroklimat goracy Temperatura powietrza\nZakres:\nZakres (15 – 50) °C\nTemperatura wilgotna naturalna (15 – 50) °C\nTemperatura poczernionej kuli (15 – 60) °C\nPredkosc powietrza (0,15 – 5,0) m/s\nMetoda pomiarowa bezposrednia PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020-04","categories":["environment"],"row_index":125,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(15 – 50) °C"},{"name":"Natural wet bulb temperature","range":"(15 – 50) °C"},{"name":"Black globe temperature","range":"(15 – 60) °C"},{"name":"Air velocity","range":"(0,15 – 5,0) m/s"}],"search_en":"Workplace environment - hot microclimate Air temperature Direct measurement method Range Natural wet bulb temperature Black globe temperature Air velocity PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020-04","technique_en":"Direct measurement method","test_object_en":"Workplace environment - hot microclimate","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(15 – 50) °C"},{"name":"自然湿球温度","range":"(15 – 50) °C"},{"name":"黑球温度","range":"(15 – 60) °C"},{"name":"空气流速","range":"(0,15 – 5,0) m/s"}],"search_zh":"工作场所环境 — 高温微气候 空气温度 直接测量法 范围 自然湿球温度 黑球温度 空气流速 PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020-04","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 高温微气候"},{"_id":"6a837436af14b9c0e7b1f3c9","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat gorący","methodology":"Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń)","reference":"PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020-04","norm_bases":["PN-EN ISO 7243:2018-01","PN-EN ISO 7243:2018-01/Ap2:2020-04"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań i Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat gorący Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń) PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020-04 Srodowisko pracy - mikroklimat goracy Wskaznik WBGT, Wskaznik WBGTeff (z obliczen) PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020-04","categories":["environment"],"row_index":126,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"WBGT index, WBGTeff index (calculated)","search_en":"Workplace environment - hot microclimate WBGT index, WBGTeff index (calculated) PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020-04","test_object_en":"Workplace environment - hot microclimate","methodology_zh":"WBGT 指数、WBGTeff 指数（计算值）","search_zh":"工作场所环境 — 高温微气候 WBGT 指数、WBGTeff 指数（计算值） PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020-04","test_object_zh":"工作场所环境 — 高温微气候"},{"_id":"6a837436af14b9c0e7b1f3ca","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Środowisko pracy − mikroklimat umiarkowany","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(10 – 30)°C"},{"name":"Temperatura poczernionej kuli","range":"(10 – 35)°C"},{"name":"Wilgotność powietrza","range":"(25 – 80) %"},{"name":"Prędkość powietrza","range":"(0,15 – 1,0) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (10 – 30)°C\nTemperatura poczernionej kuli (10 – 35)°C\nWilgotność powietrza (25 – 80) %\nPrędkość powietrza (0,15 – 1,0) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7730:2006","norm_bases":["PN-EN ISO 7730:2006"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań i Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − mikroklimat umiarkowany Temperatura powietrza\nZakres:\nZakres (10 – 30)°C\nTemperatura poczernionej kuli (10 – 35)°C\nWilgotność powietrza (25 – 80) %\nPrędkość powietrza (0,15 – 1,0) m/s\nMetoda pomiarowa bezpośrednia PN-EN ISO 7730:2006 Srodowisko pracy − mikroklimat umiarkowany Temperatura powietrza\nZakres:\nZakres (10 – 30)°C\nTemperatura poczernionej kuli (10 – 35)°C\nWilgotnosc powietrza (25 – 80) %\nPredkosc powietrza (0,15 – 1,0) m/s\nMetoda pomiarowa bezposrednia PN-EN ISO 7730:2006","categories":["environment"],"row_index":127,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(10 – 30)°C"},{"name":"Black globe temperature","range":"(10 – 35)°C"},{"name":"Air humidity","range":"(25 – 80) %"},{"name":"Air velocity","range":"(0,15 – 1,0) m/s"}],"search_en":"Workplace environment − moderate microclimate Air temperature Direct measurement method Range Black globe temperature Air humidity Air velocity PN-EN ISO 7730:2006","technique_en":"Direct measurement method","test_object_en":"Workplace environment − moderate microclimate","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(10 – 30)°C"},{"name":"黑球温度","range":"(10 – 35)°C"},{"name":"空气湿度","range":"(25 – 80) %"},{"name":"空气流速","range":"(0,15 – 1,0) m/s"}],"search_zh":"工作场所环境 − 中等微气候 空气温度 直接测量法 范围 黑球温度 空气湿度 空气流速 PN-EN ISO 7730:2006","technique_zh":"直接测量法","test_object_zh":"工作场所环境 − 中等微气候"},{"_id":"6a837436af14b9c0e7b1f3cb","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Środowisko pracy − mikroklimat umiarkowany","methodology":"Wskaźnik PMV, Wskaźnik PPD (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik PMV, Wskaźnik PPD (z obliczeń)","reference":"PN-EN ISO 7730:2006","norm_bases":["PN-EN ISO 7730:2006"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań i Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − mikroklimat umiarkowany Wskaźnik PMV, Wskaźnik PPD (z obliczeń) PN-EN ISO 7730:2006 Srodowisko pracy − mikroklimat umiarkowany Wskaznik PMV, Wskaznik PPD (z obliczen) PN-EN ISO 7730:2006","categories":["environment"],"row_index":128,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"PMV index, PPD index (calculated)","search_en":"Workplace environment − moderate microclimate PMV index, PPD index (calculated) PN-EN ISO 7730:2006","test_object_en":"Workplace environment − moderate microclimate","methodology_zh":"PMV 指数、PPD 指数（计算值）","search_zh":"工作场所环境 − 中等微气候 PMV 指数、PPD 指数（计算值） PN-EN ISO 7730:2006","test_object_zh":"工作场所环境 − 中等微气候"},{"_id":"6a837436af14b9c0e7b1f3cc","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń do magnetoterapii","methodology":"Indukcja magnetyczna:","parameters":[{"name":"w zakresie częstotliwości od 10 Hz","range":"do 400 kHz"},{"name":"Zakres","range":"(1,0 – 19000) μT"}],"technique":"Metoda pomiarowa bezpośrednia (uproszczona)","techniques":["Metoda pomiarowa bezpośrednia (uproszczona)"],"computed":[],"activity":"Indukcja magnetyczna:\nZakres:\nw zakresie częstotliwości od 10 Hz do 400 kHz\nZakres (1,0 – 19000) μT\nMetoda pomiarowa bezpośrednia (uproszczona)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), str. 151-180","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), str. 151-180"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań i Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (tj. Dz. U. z 2018 r. poz. 331)","flexible":false,"search_text":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń do magnetoterapii Indukcja magnetyczna:\nZakres:\nw zakresie częstotliwości od 10 Hz do 400 kHz\nZakres (1,0 – 19000) μT\nMetoda pomiarowa bezpośrednia (uproszczona) Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), str. 151-180 Srodowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzace od urzadzen do magnetoterapii Indukcja magnetyczna:\nZakres:\nw zakresie czestotliwosci od 10 Hz do 400 kHz\nZakres (1,0 – 19000) μT\nMetoda pomiarowa bezposrednia (uproszczona) Podstawy i Metody Oceny Srodowiska Pracy 2016, nr 4 (90), str. 151-180","categories":["environment"],"row_index":129,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic flux density:","parameters_en":[{"name":"in the frequency range from 10 Hz","range":"do 400 kHz"},{"name":"Range","range":"(1,0 – 19000) μT"}],"search_en":"Workplace environment – electromagnetic field in the workspace from magnetotherapy devices Magnetic flux density: Direct measurement method (simplified) in the frequency range from 10 Hz Range Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), str. 151-180","technique_en":"Direct measurement method (simplified)","test_object_en":"Workplace environment – electromagnetic field in the workspace from magnetotherapy devices","parameters_zh":[{"name":"频率范围自 10 Hz 起","range":"do 400 kHz"},{"name":"范围","range":"(1,0 – 19000) μT"}],"search_zh":"工作环境 － 作业空间内由磁疗设备产生的电磁场 磁感应强度： 直接测量法（简化） 频率范围自 10 Hz 起 范围 Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), str. 151-180","methodology_zh":"磁感应强度：","technique_zh":"直接测量法（简化）","test_object_zh":"工作环境 － 作业空间内由磁疗设备产生的电磁场"},{"_id":"6a837436af14b9c0e7b1f3cd","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń do magnetoterapii","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości od 10 Hz","range":"do 400 kHz"},{"name":"(z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 10 Hz do 400 kHz\n(z obliczeń)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), str. 151-180","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), str. 151-180"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań i Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (tj. Dz. U. z 2018 r. poz. 331)","flexible":false,"search_text":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń do magnetoterapii Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 10 Hz do 400 kHz\n(z obliczeń) Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), str. 151-180 Srodowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzace od urzadzen do magnetoterapii Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 10 Hz do 400 kHz\n(z obliczen) Podstawy i Metody Oceny Srodowiska Pracy 2016, nr 4 (90), str. 151-180","categories":["environment"],"row_index":130,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength:","parameters_en":[{"name":"in the frequency range from 10 Hz","range":"do 400 kHz"},{"name":"(calculated)"}],"search_en":"Workplace environment – electromagnetic field in the workspace from magnetotherapy devices Magnetic field strength: in the frequency range from 10 Hz (calculated) Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), str. 151-180","test_object_en":"Workplace environment – electromagnetic field in the workspace from magnetotherapy devices","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围自 10 Hz 起","range":"do 400 kHz"},{"name":"（计算得出）"}],"search_zh":"工作环境 － 作业空间内由磁疗设备产生的电磁场 磁场强度： 频率范围自 10 Hz 起 （计算得出） Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), str. 151-180","test_object_zh":"工作环境 － 作业空间内由磁疗设备产生的电磁场"},{"_id":"6a837436af14b9c0e7b1f3ce","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne od instalacji i urządzeń przemysłowych: - urządzenia do grzania dielektrycznego","methodology":"Natężenie pola elektrycznego w zakresie częstotliwości: od 100 kHz do 18 GHz","parameters":[{"name":"Zakres","range":"(0,5 – 1000) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego w zakresie częstotliwości: od 100 kHz do 18 GHz\nZakres (0,5 – 1000) V/m\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB/L-100 wydanie 3 z dnia 03.04.2025 r.","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","PB/L-100 wydanie 3 z dnia 03.04.2025 r."],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań i Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne od instalacji i urządzeń przemysłowych: - urządzenia do grzania dielektrycznego Natężenie pola elektrycznego w zakresie częstotliwości: od 100 kHz do 18 GHz\nZakres (0,5 – 1000) V/m\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB/L-100 wydanie 3 z dnia 03.04.2025 r. Srodowisko pracy - pole elektromagnetyczne od instalacji i urzadzen przemyslowych: - urzadzenia do grzania dielektrycznego Natezenie pola elektrycznego w zakresie czestotliwosci: od 100 kHz do 18 GHz\nZakres (0,5 – 1000) V/m\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB/L-100 wydanie 3 z dnia 03.04.2025 r.","categories":["environment"],"row_index":131,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electric field strength in the frequency range: from 100 kHz to 18 GHz","parameters_en":[{"name":"Range","range":"(0,5 – 1000) V/m"}],"search_en":"Workplace environment - electromagnetic field from industrial installations and equipment: - dielectric heating equipment Electric field strength in the frequency range: from 100 kHz to 18 GHz Direct measurement method Range PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB/L-100 wydanie 3 z dnia 03.04.2025 r.","technique_en":"Direct measurement method","test_object_en":"Workplace environment - electromagnetic field from industrial installations and equipment: - dielectric heating equipment","parameters_zh":[{"name":"范围","range":"(0,5 – 1000) V/m"}],"search_zh":"直接测量法 范围 PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB/L-100 wydanie 3 z dnia 03.04.2025 r.","technique_zh":"直接测量法"},{"_id":"6a837436af14b9c0e7b1f3cf","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne od instalacji i urządzeń przemysłowych: - urządzenia do grzania dielektrycznego","methodology":"Natężenie pola magnetycznego w zakresie częstotliwości: od 300 kHz do 1 GHz","parameters":[{"name":"Zakres","range":"(0,010 – 16) A/m"}],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego w zakresie częstotliwości: od 300 kHz do 1 GHz\nZakres (0,010 – 16) A/m","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB/L-100 wydanie 3 z dnia 03.04.2025 r.","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","PB/L-100 wydanie 3 z dnia 03.04.2025 r."],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań i Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne od instalacji i urządzeń przemysłowych: - urządzenia do grzania dielektrycznego Natężenie pola magnetycznego w zakresie częstotliwości: od 300 kHz do 1 GHz\nZakres (0,010 – 16) A/m PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB/L-100 wydanie 3 z dnia 03.04.2025 r. Srodowisko pracy - pole elektromagnetyczne od instalacji i urzadzen przemyslowych: - urzadzenia do grzania dielektrycznego Natezenie pola magnetycznego w zakresie czestotliwosci: od 300 kHz do 1 GHz\nZakres (0,010 – 16) A/m PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB/L-100 wydanie 3 z dnia 03.04.2025 r.","categories":["environment"],"row_index":132,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength in the frequency range: from 300 kHz to 1 GHz","parameters_en":[{"name":"Range","range":"(0,010 – 16) A/m"}],"search_en":"Workplace environment - electromagnetic field from industrial installations and equipment: - dielectric heating equipment Magnetic field strength in the frequency range: from 300 kHz to 1 GHz Range PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB/L-100 wydanie 3 z dnia 03.04.2025 r.","test_object_en":"Workplace environment - electromagnetic field from industrial installations and equipment: - dielectric heating equipment","parameters_zh":[{"name":"范围","range":"(0,010 – 16) A/m"}],"search_zh":"范围 PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB/L-100 wydanie 3 z dnia 03.04.2025 r."},{"_id":"6a837436af14b9c0e7b1f3d0","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Środowisko pracy − pole elektromagnetyczne pochodzące od urządzeń stosowanych w technice medycznej: - diatermie chirurgiczne - diatermie fizykoterapeutyczne","methodology":"Natężenie pola elektrycznego w zakresie częstotliwości: od 100 kHz do 18 GHz","parameters":[{"name":"Zakres","range":"(0,5 – 1000) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego w zakresie częstotliwości: od 100 kHz do 18 GHz\nZakres (0,5 – 1000) V/m\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB/L-100 wydanie 3 z dnia 03.04.2025 r.","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","PB/L-100 wydanie 3 z dnia 03.04.2025 r."],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań i Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − pole elektromagnetyczne pochodzące od urządzeń stosowanych w technice medycznej: - diatermie chirurgiczne - diatermie fizykoterapeutyczne Natężenie pola elektrycznego w zakresie częstotliwości: od 100 kHz do 18 GHz\nZakres (0,5 – 1000) V/m\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB/L-100 wydanie 3 z dnia 03.04.2025 r. Srodowisko pracy − pole elektromagnetyczne pochodzace od urzadzen stosowanych w technice medycznej: - diatermie chirurgiczne - diatermie fizykoterapeutyczne Natezenie pola elektrycznego w zakresie czestotliwosci: od 100 kHz do 18 GHz\nZakres (0,5 – 1000) V/m\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB/L-100 wydanie 3 z dnia 03.04.2025 r.","categories":["environment"],"row_index":133,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electric field strength in the frequency range: from 100 kHz to 18 GHz","parameters_en":[{"name":"Range","range":"(0,5 – 1000) V/m"}],"search_en":"Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units Electric field strength in the frequency range: from 100 kHz to 18 GHz Direct measurement method Range PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB/L-100 wydanie 3 z dnia 03.04.2025 r.","technique_en":"Direct measurement method","test_object_en":"Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units","parameters_zh":[{"name":"范围","range":"(0,5 – 1000) V/m"}],"search_zh":"工作环境 － 医疗技术设备产生的电磁场：－ 外科电刀 － 理疗透热治疗仪 直接测量法 范围 PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB/L-100 wydanie 3 z dnia 03.04.2025 r.","technique_zh":"直接测量法","test_object_zh":"工作环境 － 医疗技术设备产生的电磁场：－ 外科电刀 － 理疗透热治疗仪"},{"_id":"6a837436af14b9c0e7b1f3d1","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Środowisko pracy − pole elektromagnetyczne pochodzące od urządzeń stosowanych w technice medycznej: - diatermie chirurgiczne - diatermie fizykoterapeutyczne","methodology":"Natężenie pola magnetycznego w zakresie częstotliwości: od 300 kHz do 1 GHz","parameters":[{"name":"Zakres","range":"(0,010 – 16) A/m"}],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego w zakresie częstotliwości: od 300 kHz do 1 GHz\nZakres (0,010 – 16) A/m","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB/L-100 wydanie 3 z dnia 03.04.2025 r.","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","PB/L-100 wydanie 3 z dnia 03.04.2025 r."],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań i Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − pole elektromagnetyczne pochodzące od urządzeń stosowanych w technice medycznej: - diatermie chirurgiczne - diatermie fizykoterapeutyczne Natężenie pola magnetycznego w zakresie częstotliwości: od 300 kHz do 1 GHz\nZakres (0,010 – 16) A/m PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB/L-100 wydanie 3 z dnia 03.04.2025 r. Srodowisko pracy − pole elektromagnetyczne pochodzace od urzadzen stosowanych w technice medycznej: - diatermie chirurgiczne - diatermie fizykoterapeutyczne Natezenie pola magnetycznego w zakresie czestotliwosci: od 300 kHz do 1 GHz\nZakres (0,010 – 16) A/m PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB/L-100 wydanie 3 z dnia 03.04.2025 r.","categories":["environment"],"row_index":134,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength in the frequency range: from 300 kHz to 1 GHz","parameters_en":[{"name":"Range","range":"(0,010 – 16) A/m"}],"search_en":"Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units Magnetic field strength in the frequency range: from 300 kHz to 1 GHz Range PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB/L-100 wydanie 3 z dnia 03.04.2025 r.","test_object_en":"Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units","parameters_zh":[{"name":"范围","range":"(0,010 – 16) A/m"}],"search_zh":"工作环境 － 医疗技术设备产生的电磁场：－ 外科电刀 － 理疗透热治疗仪 范围 PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB/L-100 wydanie 3 z dnia 03.04.2025 r.","test_object_zh":"工作环境 － 医疗技术设备产生的电磁场：－ 外科电刀 － 理疗透热治疗仪"},{"_id":"6a837436af14b9c0e7b1f3d2","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Środowisko pracy − pole elektromagnetyczne pochodzące od urządzeń stosowanych w technice medycznej: - diatermie chirurgiczne - diatermie fizykoterapeutyczne","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości od 1","range":"do 3 GHz"},{"name":"(z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 1 do 3 GHz\n(z obliczeń)","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB/L-100 wydanie 3 z dnia 03.04.2025 r.","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","PB/L-100 wydanie 3 z dnia 03.04.2025 r."],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań i Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − pole elektromagnetyczne pochodzące od urządzeń stosowanych w technice medycznej: - diatermie chirurgiczne - diatermie fizykoterapeutyczne Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 1 do 3 GHz\n(z obliczeń) PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB/L-100 wydanie 3 z dnia 03.04.2025 r. Srodowisko pracy − pole elektromagnetyczne pochodzace od urzadzen stosowanych w technice medycznej: - diatermie chirurgiczne - diatermie fizykoterapeutyczne Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 1 do 3 GHz\n(z obliczen) PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB/L-100 wydanie 3 z dnia 03.04.2025 r.","categories":["environment"],"row_index":135,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength:","parameters_en":[{"name":"in the frequency range from 1","range":"do 3 GHz"},{"name":"(calculated)"}],"search_en":"Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units Magnetic field strength: in the frequency range from 1 (calculated) PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB/L-100 wydanie 3 z dnia 03.04.2025 r.","test_object_en":"Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围自 1 起","range":"do 3 GHz"},{"name":"（计算得出）"}],"search_zh":"工作环境 － 医疗技术设备产生的电磁场：－ 外科电刀 － 理疗透热治疗仪 磁场强度： 频率范围自 1 起 （计算得出） PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB/L-100 wydanie 3 z dnia 03.04.2025 r.","test_object_zh":"工作环境 － 医疗技术设备产生的电磁场：－ 外科电刀 － 理疗透热治疗仪"},{"_id":"6a837436af14b9c0e7b1f3d3","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Pobieranie próbek w celu oceny narażenia zawodowego na:","parameters":[{"name":"czynniki pyłowe"},{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna"}],"technique":"Metoda dozymetrii indywidualnej","techniques":["Metoda dozymetrii indywidualnej"],"computed":[],"activity":"Pobieranie próbek w celu oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe\nfrakcja wdychalna\nfrakcja respirabilna\nMetoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002","norm_bases":["PN-Z-04008-7:2002"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań i Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Pobieranie próbek w celu oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe\nfrakcja wdychalna\nfrakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002 Srodowisko pracy - powietrze Pobieranie probek w celu oceny narazenia zawodowego na:\nZakres:\nczynniki pylowe\nfrakcja wdychalna\nfrakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002","categories":["environment"],"row_index":136,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for the assessment of occupational exposure to:","parameters_en":[{"name":"dust agents"},{"name":"inhalable fraction"},{"name":"respirable fraction"}],"search_en":"Workplace environment - air Sampling for the assessment of occupational exposure to: Personal dosimetry method dust agents inhalable fraction respirable fraction PN-Z-04008-7:2002","technique_en":"Personal dosimetry method","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"粉尘因素"},{"name":"可吸入组分"},{"name":"呼吸性组分"}],"search_zh":"工作场所环境 — 空气 职业接触评估采样，针对： 个体剂量测定法 粉尘因素 可吸入组分 呼吸性组分 PN-Z-04008-7:2002","technique_zh":"个体剂量测定法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"职业接触评估采样，针对："},{"_id":"6a837436af14b9c0e7b1f3d4","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Wskaźnik narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PN-Z-04008-7:2002","norm_bases":["PN-Z-04008-7:2002"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań i Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Wskaźnik narażenia (z obliczeń) PN-Z-04008-7:2002 Srodowisko pracy - powietrze Wskaznik narazenia (z obliczen) PN-Z-04008-7:2002","categories":["environment"],"row_index":137,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Exposure index (calculated)","search_en":"Workplace environment - air Exposure index (calculated) PN-Z-04008-7:2002","test_object_en":"Workplace environment - air","methodology_zh":"暴露指数（计算得出）","search_zh":"工作场所环境 — 空气 暴露指数（计算得出） PN-Z-04008-7:2002","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a837436af14b9c0e7b1f3d5","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie pyłowych czynników szkodliwych - frakcja wdychalna","parameters":[{"name":"Grafit naturalny"},{"name":"Grafit syntetyczny"},{"name":"Krzemionka bezpostaciowa i syntetyczna"},{"name":"Pyły drewna"},{"name":"Pyły mąki"},{"name":"Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Sadza techniczna"},{"name":"Węglan wapnia"},{"name":"Zakres","range":"(0,15 – 20,00) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych - frakcja wdychalna\nZakres:\nGrafit naturalny\nGrafit syntetyczny\nKrzemionka bezpostaciowa i syntetyczna\nPyły drewna\nPyły mąki\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nSadza techniczna\nWęglan wapnia\nZakres (0,15 – 20,00) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04507:2022-05","PN-Z-04507:2022-05/Ap1:2022-08"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań i Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie pyłowych czynników szkodliwych - frakcja wdychalna\nZakres:\nGrafit naturalny\nGrafit syntetyczny\nKrzemionka bezpostaciowa i syntetyczna\nPyły drewna\nPyły mąki\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nSadza techniczna\nWęglan wapnia\nZakres (0,15 – 20,00) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08 Srodowisko pracy - powietrze Stezenie pylowych czynnikow szkodliwych - frakcja wdychalna\nZakres:\nGrafit naturalny\nGrafit syntetyczny\nKrzemionka bezpostaciowa i syntetyczna\nPyly drewna\nPyly maki\nPyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nSadza techniczna\nWeglan wapnia\nZakres (0,15 – 20,00) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","categories":["environment"],"row_index":138,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of harmful dust agents - inhalable fraction","parameters_en":[{"name":"Natural graphite"},{"name":"Synthetic graphite"},{"name":"Amorphous and synthetic silica"},{"name":"Wood dusts"},{"name":"Flour dusts"},{"name":"Organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"Carbon black"},{"name":"Calcium carbonate"},{"name":"Range","range":"(0,15 – 20,00) mg/m3"}],"search_en":"Workplace environment - air Concentration of harmful dust agents - inhalable fraction Gravimetric method Natural graphite Synthetic graphite Amorphous and synthetic silica Wood dusts Flour dusts Organic dusts of animal and plant origin, excluding wood and flour dusts Carbon black Calcium carbonate Range PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"天然石墨"},{"name":"合成石墨"},{"name":"无定形与合成二氧化硅"},{"name":"木粉尘"},{"name":"面粉粉尘"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"炭黑"},{"name":"Węglan wapnia"},{"name":"范围","range":"(0,15 – 20,00) mg/m3"}],"search_zh":"工作场所环境 — 空气 重量法 天然石墨 合成石墨 无定形与合成二氧化硅 木粉尘 面粉粉尘 动植物来源有机粉尘，木粉和面粉除外 炭黑 范围 PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a837436af14b9c0e7b1f3d6","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie pyłowych czynników szkodliwych - frakcja respirabilna","parameters":[{"name":"Grafit naturalny"},{"name":"Krzemionka bezpostaciowa i syntetyczna"},{"name":"Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Zakres","range":"(0,10 – 9,26) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych - frakcja respirabilna\nZakres:\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nZakres (0,10 – 9,26) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04508:2022-05","PN-Z-04508:2022-05/Ap1:2022-08"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań i Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie pyłowych czynników szkodliwych - frakcja respirabilna\nZakres:\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nZakres (0,10 – 9,26) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08 Srodowisko pracy - powietrze Stezenie pylowych czynnikow szkodliwych - frakcja respirabilna\nZakres:\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nZakres (0,10 – 9,26) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","categories":["environment"],"row_index":139,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of harmful dust agents - respirable fraction","parameters_en":[{"name":"Natural graphite"},{"name":"Amorphous and synthetic silica"},{"name":"Organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"Range","range":"(0,10 – 9,26) mg/m3"}],"search_en":"Workplace environment - air Concentration of harmful dust agents - respirable fraction Gravimetric method Natural graphite Amorphous and synthetic silica Organic dusts of animal and plant origin, excluding wood and flour dusts Range PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"天然石墨"},{"name":"无定形与合成二氧化硅"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"范围","range":"(0,10 – 9,26) mg/m3"}],"search_zh":"工作场所环境 — 空气 重量法 天然石墨 无定形与合成二氧化硅 动植物来源有机粉尘，木粉和面粉除外 范围 PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a837436af14b9c0e7b1f3d7","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Urządzenie stosowane w stomatologii – aparaty do zdjęć wewnątrzustnych","methodology":"Testy specjalistyczne","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Testy specjalistyczne","reference":"Załącznik nr 1 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. 2022 poz. 2759) | PB/L-93 wydanie 3 z dnia 24.02.2023 r.","norm_bases":["Załącznik nr 1 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. 2022 poz. 2759)","PB/L-93 wydanie 3 z dnia 24.02.2023 r."],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań Radiacyjnych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenie stosowane w stomatologii – aparaty do zdjęć wewnątrzustnych Testy specjalistyczne Załącznik nr 1 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. 2022 poz. 2759) | PB/L-93 wydanie 3 z dnia 24.02.2023 r. Urzadzenie stosowane w stomatologii – aparaty do zdjec wewnatrzustnych Testy specjalistyczne Zalacznik nr 1 do rozporzadzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. 2022 poz. 2759) | PB/L-93 wydanie 3 z dnia 24.02.2023 r.","categories":["other"],"row_index":140,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Specialist tests","search_en":"Dental equipment – intraoral radiography units Specialist tests Załącznik nr 1 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. 2022 poz. 2759) | PB/L-93 wydanie 3 z dnia 24.02.2023 r.","test_object_en":"Dental equipment – intraoral radiography units","methodology_zh":"专项检测","search_zh":"口腔科设备 — 口内摄影 X 射线机 专项检测 Załącznik nr 1 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. 2022 poz. 2759) | PB/L-93 wydanie 3 z dnia 24.02.2023 r.","test_object_zh":"口腔科设备 — 口内摄影 X 射线机"},{"_id":"6a837436af14b9c0e7b1f3d8","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Urządzenia stosowane w radiografii ogólnej cyfrowej","methodology":"Testy specjalistyczne","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Testy specjalistyczne","reference":"Załącznik nr 1 i 2 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. z 2022 r. poz. 2759) | PB/L-96 wydanie 5 z dnia 19.04.2023 r. | PB/L-109 wydanie 1 z dnia 24.02.2023 r.","norm_bases":["Załącznik nr 1 i 2 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. z 2022 r. poz. 2759)","PB/L-96 wydanie 5 z dnia 19.04.2023 r.","PB/L-109 wydanie 1 z dnia 24.02.2023 r."],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań Radiacyjnych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia stosowane w radiografii ogólnej cyfrowej Testy specjalistyczne Załącznik nr 1 i 2 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. z 2022 r. poz. 2759) | PB/L-96 wydanie 5 z dnia 19.04.2023 r. | PB/L-109 wydanie 1 z dnia 24.02.2023 r. Urzadzenia stosowane w radiografii ogolnej cyfrowej Testy specjalistyczne Zalacznik nr 1 i 2 do rozporzadzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. z 2022 r. poz. 2759) | PB/L-96 wydanie 5 z dnia 19.04.2023 r. | PB/L-109 wydanie 1 z dnia 24.02.2023 r.","categories":["other"],"row_index":141,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Specialist tests","search_en":"Equipment used in general digital radiography Specialist tests Załącznik nr 1 i 2 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. z 2022 r. poz. 2759) | PB/L-96 wydanie 5 z dnia 19.04.2023 r. | PB/L-109 wydanie 1 z dnia 24.02.2023 r.","test_object_en":"Equipment used in general digital radiography","methodology_zh":"专项检测","search_zh":"数字普通放射摄影用设备 专项检测 Załącznik nr 1 i 2 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. z 2022 r. poz. 2759) | PB/L-96 wydanie 5 z dnia 19.04.2023 r. | PB/L-109 wydanie 1 z dnia 24.02.2023 r.","test_object_zh":"数字普通放射摄影用设备"},{"_id":"6a837436af14b9c0e7b1f3d9","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Urządzenie stosowane w stomatologii – aparaty do zdjęć pantomograficznych oraz cefalometrii analogowej","methodology":"Testy specjalistyczne","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Testy specjalistyczne","reference":"Załącznik nr 1 i 2 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. z 2022 r. poz. 2759) | PB/L-94 wydanie 4 z dnia 19.04.2023 r. | PB/L-109 wydanie 1 z dnia 24.02.2023 r.","norm_bases":["Załącznik nr 1 i 2 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. z 2022 r. poz. 2759)","PB/L-94 wydanie 4 z dnia 19.04.2023 r.","PB/L-109 wydanie 1 z dnia 24.02.2023 r."],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań Radiacyjnych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenie stosowane w stomatologii – aparaty do zdjęć pantomograficznych oraz cefalometrii analogowej Testy specjalistyczne Załącznik nr 1 i 2 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. z 2022 r. poz. 2759) | PB/L-94 wydanie 4 z dnia 19.04.2023 r. | PB/L-109 wydanie 1 z dnia 24.02.2023 r. Urzadzenie stosowane w stomatologii – aparaty do zdjec pantomograficznych oraz cefalometrii analogowej Testy specjalistyczne Zalacznik nr 1 i 2 do rozporzadzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. z 2022 r. poz. 2759) | PB/L-94 wydanie 4 z dnia 19.04.2023 r. | PB/L-109 wydanie 1 z dnia 24.02.2023 r.","categories":["other"],"row_index":142,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Specialist tests","search_en":"Dental equipment – panoramic radiography and analogue cephalometry units Specialist tests Załącznik nr 1 i 2 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. z 2022 r. poz. 2759) | PB/L-94 wydanie 4 z dnia 19.04.2023 r. | PB/L-109 wydanie 1 z dnia 24.02.2023 r.","test_object_en":"Dental equipment – panoramic radiography and analogue cephalometry units","methodology_zh":"专项检测","search_zh":"口腔科设备 — 全景摄影与模拟头影测量 X 射线机 专项检测 Załącznik nr 1 i 2 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. z 2022 r. poz. 2759) | PB/L-94 wydanie 4 z dnia 19.04.2023 r. | PB/L-109 wydanie 1 z dnia 24.02.2023 r.","test_object_zh":"口腔科设备 — 全景摄影与模拟头影测量 X 射线机"},{"_id":"6a837436af14b9c0e7b1f3da","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Urządzenie stosowane w stomatologii – aparaty do zdjęć pantomograficznych oraz cefalometrii cyfrowej","methodology":"Testy specjalistyczne","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Testy specjalistyczne","reference":"Załącznik nr 1 i 2 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. z 2022 r. poz. 2759) | PB/L-94 wydanie 4 z dnia 19.04.2023 r. | PB/L-109 wydanie 1 z dnia 24.02.2023 r.","norm_bases":["Załącznik nr 1 i 2 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. z 2022 r. poz. 2759)","PB/L-94 wydanie 4 z dnia 19.04.2023 r.","PB/L-109 wydanie 1 z dnia 24.02.2023 r."],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań Radiacyjnych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenie stosowane w stomatologii – aparaty do zdjęć pantomograficznych oraz cefalometrii cyfrowej Testy specjalistyczne Załącznik nr 1 i 2 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. z 2022 r. poz. 2759) | PB/L-94 wydanie 4 z dnia 19.04.2023 r. | PB/L-109 wydanie 1 z dnia 24.02.2023 r. Urzadzenie stosowane w stomatologii – aparaty do zdjec pantomograficznych oraz cefalometrii cyfrowej Testy specjalistyczne Zalacznik nr 1 i 2 do rozporzadzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. z 2022 r. poz. 2759) | PB/L-94 wydanie 4 z dnia 19.04.2023 r. | PB/L-109 wydanie 1 z dnia 24.02.2023 r.","categories":["other"],"row_index":143,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Specialist tests","search_en":"Dental equipment – panoramic radiography and digital cephalometry units Specialist tests Załącznik nr 1 i 2 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. z 2022 r. poz. 2759) | PB/L-94 wydanie 4 z dnia 19.04.2023 r. | PB/L-109 wydanie 1 z dnia 24.02.2023 r.","test_object_en":"Dental equipment – panoramic radiography and digital cephalometry units","methodology_zh":"专项检测","search_zh":"口腔科设备 — 全景摄影与数字头影测量 X 射线机 专项检测 Załącznik nr 1 i 2 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. z 2022 r. poz. 2759) | PB/L-94 wydanie 4 z dnia 19.04.2023 r. | PB/L-109 wydanie 1 z dnia 24.02.2023 r.","test_object_zh":"口腔科设备 — 全景摄影与数字头影测量 X 射线机"},{"_id":"6a837436af14b9c0e7b1f3db","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Urządzenie stosowane w stomatologicznej tomografii komputerowej wiązki stożkowej","methodology":"Testy specjalistyczne","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Testy specjalistyczne","reference":"Załącznik nr 1 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. z 2022 r. poz. 2759) | PB/L-106 wydanie 3 z dnia 24.02.2023 r.","norm_bases":["Załącznik nr 1 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. z 2022 r. poz. 2759)","PB/L-106 wydanie 3 z dnia 24.02.2023 r."],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań Radiacyjnych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenie stosowane w stomatologicznej tomografii komputerowej wiązki stożkowej Testy specjalistyczne Załącznik nr 1 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. z 2022 r. poz. 2759) | PB/L-106 wydanie 3 z dnia 24.02.2023 r. Urzadzenie stosowane w stomatologicznej tomografii komputerowej wiazki stozkowej Testy specjalistyczne Zalacznik nr 1 do rozporzadzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. z 2022 r. poz. 2759) | PB/L-106 wydanie 3 z dnia 24.02.2023 r.","categories":["other"],"row_index":144,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Specialist tests","search_en":"Equipment used in dental cone beam computed tomography Specialist tests Załącznik nr 1 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. z 2022 r. poz. 2759) | PB/L-106 wydanie 3 z dnia 24.02.2023 r.","test_object_en":"Equipment used in dental cone beam computed tomography","methodology_zh":"专项检测","search_zh":"口腔锥形束计算机断层扫描用设备 专项检测 Załącznik nr 1 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. z 2022 r. poz. 2759) | PB/L-106 wydanie 3 z dnia 24.02.2023 r.","test_object_zh":"口腔锥形束计算机断层扫描用设备"},{"_id":"6a837436af14b9c0e7b1f3dc","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Urządzenia stosowane we fluoroskopii i angiografii","methodology":"Testy specjalistyczne","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Testy specjalistyczne","reference":"Załącznik nr 1 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. z 2022 r. poz. 2759) | PB/L-97 wydanie 5 z dnia 19.04.2023 r.","norm_bases":["Załącznik nr 1 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. z 2022 r. poz. 2759)","PB/L-97 wydanie 5 z dnia 19.04.2023 r."],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań Radiacyjnych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia stosowane we fluoroskopii i angiografii Testy specjalistyczne Załącznik nr 1 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. z 2022 r. poz. 2759) | PB/L-97 wydanie 5 z dnia 19.04.2023 r. Urzadzenia stosowane we fluoroskopii i angiografii Testy specjalistyczne Zalacznik nr 1 do rozporzadzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. z 2022 r. poz. 2759) | PB/L-97 wydanie 5 z dnia 19.04.2023 r.","categories":["other"],"row_index":145,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Specialist tests","search_en":"Equipment used in fluoroscopy and angiography Specialist tests Załącznik nr 1 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. z 2022 r. poz. 2759) | PB/L-97 wydanie 5 z dnia 19.04.2023 r.","test_object_en":"Equipment used in fluoroscopy and angiography","methodology_zh":"专项检测","search_zh":"透视与血管造影用设备 专项检测 Załącznik nr 1 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. z 2022 r. poz. 2759) | PB/L-97 wydanie 5 z dnia 19.04.2023 r.","test_object_zh":"透视与血管造影用设备"},{"_id":"6a837436af14b9c0e7b1f3dd","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Monitory stosowane do prezentacji obrazów medycznych","methodology":"Testy specjalistyczne","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Testy specjalistyczne","reference":"Załącznik nr 2 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. z 2022 r. poz. 2759) | PB/L-98 wydanie 3 z dnia 24.02.2023 r.","norm_bases":["Załącznik nr 2 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. z 2022 r. poz. 2759)","PB/L-98 wydanie 3 z dnia 24.02.2023 r."],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań Radiacyjnych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Monitory stosowane do prezentacji obrazów medycznych Testy specjalistyczne Załącznik nr 2 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. z 2022 r. poz. 2759) | PB/L-98 wydanie 3 z dnia 24.02.2023 r. Monitory stosowane do prezentacji obrazow medycznych Testy specjalistyczne Zalacznik nr 2 do rozporzadzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. z 2022 r. poz. 2759) | PB/L-98 wydanie 3 z dnia 24.02.2023 r.","categories":["other"],"row_index":146,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Specialist tests","search_en":"Monitors used for the display of medical images Specialist tests Załącznik nr 2 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. z 2022 r. poz. 2759) | PB/L-98 wydanie 3 z dnia 24.02.2023 r.","test_object_en":"Monitors used for the display of medical images","methodology_zh":"专项检测","search_zh":"医学影像显示用监视器 专项检测 Załącznik nr 2 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz. U. z 2022 r. poz. 2759) | PB/L-98 wydanie 3 z dnia 24.02.2023 r.","test_object_zh":"医学影像显示用监视器"},{"_id":"6a837436af14b9c0e7b1f3de","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Promieniowanie jonizujące, Żywność","methodology":"Stężenie aktywności radionuklidu: 137 Cs","parameters":[{"name":"Zakres","range":"(0,2 – 5000) Bq/kg"}],"technique":"Metoda spektometrii promieniowania gamma","techniques":["Metoda spektometrii promieniowania gamma"],"computed":[],"activity":"Stężenie aktywności radionuklidu: 137 Cs\nZakres (0,2 – 5000) Bq/kg\nMetoda spektometrii promieniowania gamma","reference":"PB/L-67 wydanie 3 z dnia 11.03.2024r.","norm_bases":["PB/L-67 wydanie 3 z dnia 11.03.2024r."],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Badań Środowiska Pracy i Badań Radiacyjnych; Pracownia Badań Radiacyjnych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Promieniowanie jonizujące, Żywność Stężenie aktywności radionuklidu: 137 Cs\nZakres (0,2 – 5000) Bq/kg\nMetoda spektometrii promieniowania gamma PB/L-67 wydanie 3 z dnia 11.03.2024r. Promieniowanie jonizujace, Zywnosc Stezenie aktywnosci radionuklidu: 137 Cs\nZakres (0,2 – 5000) Bq/kg\nMetoda spektometrii promieniowania gamma PB/L-67 wydanie 3 z dnia 11.03.2024r.","categories":["food"],"row_index":147,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Activity concentration of radionuclide: 137 Cs","parameters_en":[{"name":"Range","range":"(0,2 – 5000) Bq/kg"}],"search_en":"Ionising radiation, Food Activity concentration of radionuclide: 137 Cs Gamma-ray spectrometry Range PB/L-67 wydanie 3 z dnia 11.03.2024r.","technique_en":"Gamma-ray spectrometry","test_object_en":"Ionising radiation, Food","parameters_zh":[{"name":"范围","range":"(0,2 – 5000) Bq/kg"}],"search_zh":"γ 射线能谱法 范围 PB/L-67 wydanie 3 z dnia 11.03.2024r.","technique_zh":"γ 射线能谱法"},{"_id":"6a837436af14b9c0e7b1f3df","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Kał, wymaz z odbytu, szczep bakteryjny","methodology":"Obecność i identyfikacja pałeczek jelitowych z rodzaju Salmonella i Shigella","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność i identyfikacja pałeczek jelitowych z rodzaju Salmonella i Shigella\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PB/L-09 wydanie 5 z dnia 10.02.2025 r. | na podstawie publikacji metodycznych","norm_bases":["PB/L-09 wydanie 5 z dnia 10.02.2025 r.","na podstawie publikacji metodycznych"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Mikrobiologii i Epidemiologii; Pracownia Bakteriologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kał, wymaz z odbytu, szczep bakteryjny Obecność i identyfikacja pałeczek jelitowych z rodzaju Salmonella i Shigella\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB/L-09 wydanie 5 z dnia 10.02.2025 r. | na podstawie publikacji metodycznych Kal, wymaz z odbytu, szczep bakteryjny Obecnosc i identyfikacja paleczek jelitowych z rodzaju Salmonella i Shigella\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB/L-09 wydanie 5 z dnia 10.02.2025 r. | na podstawie publikacji metodycznych","categories":["microbiology"],"row_index":148,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence and identification of enteric rods of the genus Salmonella and Shigella","search_en":"Faeces, rectal swab, bacterial strain Presence and identification of enteric rods of the genus Salmonella and Shigella Culture method with biochemical and serological confirmation PB/L-09 wydanie 5 z dnia 10.02.2025 r. | na podstawie publikacji metodycznych","technique_en":"Culture method with biochemical and serological confirmation","test_object_en":"Faeces, rectal swab, bacterial strain","search_zh":"粪便、肛拭子、菌株 培养法结合生化与血清学确认 PB/L-09 wydanie 5 z dnia 10.02.2025 r. | na podstawie publikacji metodycznych","technique_zh":"培养法结合生化与血清学确认","test_object_zh":"粪便、肛拭子、菌株"},{"_id":"6a837436af14b9c0e7b1f3e0","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Kał, wymaz z odbytu, szczep bakteryjny","methodology":"Obecność i identyfikacja pałeczek jelitowych z rodzaju Yersinia i Escherichia coli O 157","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność i identyfikacja pałeczek jelitowych z rodzaju Yersinia i Escherichia coli O 157\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PB/L-10 wydanie 5 z dnia 10.02.2025 r. | na podstawie publikacji metodycznych","norm_bases":["PB/L-10 wydanie 5 z dnia 10.02.2025 r.","na podstawie publikacji metodycznych"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Mikrobiologii i Epidemiologii; Pracownia Bakteriologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kał, wymaz z odbytu, szczep bakteryjny Obecność i identyfikacja pałeczek jelitowych z rodzaju Yersinia i Escherichia coli O 157\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB/L-10 wydanie 5 z dnia 10.02.2025 r. | na podstawie publikacji metodycznych Kal, wymaz z odbytu, szczep bakteryjny Obecnosc i identyfikacja paleczek jelitowych z rodzaju Yersinia i Escherichia coli O 157\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB/L-10 wydanie 5 z dnia 10.02.2025 r. | na podstawie publikacji metodycznych","categories":["microbiology"],"row_index":149,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence and identification of enteric rods of the genus Yersinia and Escherichia coli O 157","search_en":"Faeces, rectal swab, bacterial strain Presence and identification of enteric rods of the genus Yersinia and Escherichia coli O 157 Culture method with biochemical and serological confirmation PB/L-10 wydanie 5 z dnia 10.02.2025 r. | na podstawie publikacji metodycznych","technique_en":"Culture method with biochemical and serological confirmation","test_object_en":"Faeces, rectal swab, bacterial strain","search_zh":"粪便、肛拭子、菌株 培养法结合生化与血清学确认 PB/L-10 wydanie 5 z dnia 10.02.2025 r. | na podstawie publikacji metodycznych","technique_zh":"培养法结合生化与血清学确认","test_object_zh":"粪便、肛拭子、菌株"},{"_id":"6a837436af14b9c0e7b1f3e1","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Wymaz z gardła i nosa","methodology":"Obecność materiału genetycznego wirusa grypy typu A, B, A(H1N1)pmd09, A(H3N2)","parameters":[],"technique":"Metoda real time RT-PCR","techniques":["Metoda real time RT-PCR"],"computed":[],"activity":"Obecność materiału genetycznego wirusa grypy typu A, B, A(H1N1)pmd09, A(H3N2)\nMetoda real time RT-PCR","reference":"PB/L-111 wydanie 1 z dnia 18.02.2025 r. | na podstawie instrukcji producentów","norm_bases":["PB/L-111 wydanie 1 z dnia 18.02.2025 r.","na podstawie instrukcji producentów"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Mikrobiologii i Epidemiologii; Pracownia Biologii Molekularnej i Serologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wymaz z gardła i nosa Obecność materiału genetycznego wirusa grypy typu A, B, A(H1N1)pmd09, A(H3N2)\nMetoda real time RT-PCR PB/L-111 wydanie 1 z dnia 18.02.2025 r. | na podstawie instrukcji producentów Wymaz z gardla i nosa Obecnosc materialu genetycznego wirusa grypy typu A, B, A(H1N1)pmd09, A(H3N2)\nMetoda real time RT-PCR PB/L-111 wydanie 1 z dnia 18.02.2025 r. | na podstawie instrukcji producentow","categories":["materials"],"row_index":150,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of genetic material of influenza virus type A, B, A(H1N1)pmd09, A(H3N2)","search_en":"Throat and nose swab Presence of genetic material of influenza virus type A, B, A(H1N1)pmd09, A(H3N2) Real time RT-PCR method PB/L-111 wydanie 1 z dnia 18.02.2025 r. | na podstawie instrukcji producentów","technique_en":"Real time RT-PCR method","test_object_en":"Throat and nose swab","search_zh":"实时荧光定量 RT-PCR 法 PB/L-111 wydanie 1 z dnia 18.02.2025 r. | na podstawie instrukcji producentów","technique_zh":"实时荧光定量 RT-PCR 法"},{"_id":"6a837436af14b9c0e7b1f3e2","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Wymaz z gardła i nosa","methodology":"Obecność materiału genetycznego wirusów RSV typu A i B","parameters":[],"technique":"Metoda real time RT-PCR","techniques":["Metoda real time RT-PCR"],"computed":[],"activity":"Obecność materiału genetycznego wirusów RSV typu A i B\nMetoda real time RT-PCR","reference":"PB/L-111 wydanie 1 z dnia 18.02.2025 r. | na podstawie instrukcji producentów","norm_bases":["PB/L-111 wydanie 1 z dnia 18.02.2025 r.","na podstawie instrukcji producentów"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Mikrobiologii i Epidemiologii; Pracownia Biologii Molekularnej i Serologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wymaz z gardła i nosa Obecność materiału genetycznego wirusów RSV typu A i B\nMetoda real time RT-PCR PB/L-111 wydanie 1 z dnia 18.02.2025 r. | na podstawie instrukcji producentów Wymaz z gardla i nosa Obecnosc materialu genetycznego wirusow RSV typu A i B\nMetoda real time RT-PCR PB/L-111 wydanie 1 z dnia 18.02.2025 r. | na podstawie instrukcji producentow","categories":["materials"],"row_index":151,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of genetic material of RSV viruses type A and B","search_en":"Throat and nose swab Presence of genetic material of RSV viruses type A and B Real time RT-PCR method PB/L-111 wydanie 1 z dnia 18.02.2025 r. | na podstawie instrukcji producentów","technique_en":"Real time RT-PCR method","test_object_en":"Throat and nose swab","search_zh":"实时荧光定量 RT-PCR 法 PB/L-111 wydanie 1 z dnia 18.02.2025 r. | na podstawie instrukcji producentów","technique_zh":"实时荧光定量 RT-PCR 法"},{"_id":"6a837436af14b9c0e7b1f3e3","lab_id":"69ad52a3de79e566650fb2bc","country":"PL","accr_number":"AB 538","accr_body":"PCA","test_object":"Wymaz z gardła i nosa","methodology":"Obecność materiału genetycznego koronawirusa SARS-CoV-2","parameters":[],"technique":"Metoda real time RT-PCR","techniques":["Metoda real time RT-PCR"],"computed":[],"activity":"Obecność materiału genetycznego koronawirusa SARS-CoV-2\nMetoda real time RT-PCR","reference":"PB/L-111 wydanie 1 z dnia 18.02.2025 r. | na podstawie instrukcji producentów","norm_bases":["PB/L-111 wydanie 1 z dnia 18.02.2025 r.","na podstawie instrukcji producentów"],"lab_section":"Dział Laboratoryjny; Oddział Laboratoryjny Mikrobiologii i Epidemiologii; Pracownia Biologii Molekularnej i Serologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wymaz z gardła i nosa Obecność materiału genetycznego koronawirusa SARS-CoV-2\nMetoda real time RT-PCR PB/L-111 wydanie 1 z dnia 18.02.2025 r. | na podstawie instrukcji producentów Wymaz z gardla i nosa Obecnosc materialu genetycznego koronawirusa SARS-CoV-2\nMetoda real time RT-PCR PB/L-111 wydanie 1 z dnia 18.02.2025 r. | na podstawie instrukcji producentow","categories":["materials"],"row_index":152,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of genetic material of the SARS-CoV-2 coronavirus","search_en":"Throat and nose swab Presence of genetic material of the SARS-CoV-2 coronavirus Real time RT-PCR method PB/L-111 wydanie 1 z dnia 18.02.2025 r. | na podstawie instrukcji producentów","technique_en":"Real time RT-PCR method","test_object_en":"Throat and nose swab","search_zh":"实时荧光定量 RT-PCR 法 PB/L-111 wydanie 1 z dnia 18.02.2025 r. | na podstawie instrukcji producentów","technique_zh":"实时荧光定量 RT-PCR 法"}],"has_pdf":true}