{"lab":{"_id":"69ad52a3de79e566650fb2b8","accr_number":"AB 536","country":"PL","accr_body":"PCA","address":"ul. Żeromskiego 116, 90-924 Łódź, KATEDRA BUDOWNICTWA BETONOWEGO, LABORATORIUM BADAWCZE MATERIAŁÓW, I KONSTRUKCJI BUDOWLANYCH","categories":["construction","materials","water"],"city":"Łódź","imported_at":"2026-03-08T10:42:43.265Z","methods_count":28,"name":"POLITECHNIKA ŁÓDZKA","parse_status":"parsed","parse_version":2,"pdf_files":["AB_536.pdf"],"scope_summary":"","search_text":"politechnika łódzka ul. żeromskiego 116, 90-924 łódź, katedra budownictwa betonowego, laboratorium badawcze materiałów, i konstrukcji budowlanych construction other water materials electronics","status":"active","updated_at":"2026-03-08T14:51:24.610Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-13T08:08:57.562Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20536,podmiot.html","fields_of_testing":[{"codes":"J/5/P","pl":"Badania mechaniczne i pobieranie próbek wyrobów i materiałów budowlanych","en":"Mechanical tests and sampling of building products and materials"},{"codes":"J/5, J/8","pl":"Badania mechaniczne wyrobów i materiałów budowlanych i wyrobów i materiałów konstrukcyjnych","en":"Mechanical tests of building products and materials and construction products and materials"},{"codes":"N/5","pl":"Badania właściwości fizycznych wyrobów i materiałów budowlanych","en":"Tests of physical properties of building products and materials"}],"issue":{"no":"23","date":"23.06.2026"},"parse_date":"2026-08-13T08:08:57.562Z","parse_source":"agent-claude-code","map_coord":[51.752856,19.450023],"map_geo":"nominatim-street","lab_locations":[{"name":"LABORATORIUM BADAWCZE MATERIAŁÓW","address":"AB 536 Al. Politechniki 6","city":null,"postal":null},{"name":"Laboratorium Badawcze Materiałów i Konstrukcji Budowlanych","address":"Al. Politechniki 6, 93-590 Łódź","city":"Łódź","postal":"93-590"},{"name":"Laboratorium Badawcze Materiałów i Konstrukcji Budowlanych; Al. Politechniki 6, 93-590 Łódź","address":null,"city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/13/0f600d9d175392b6f5ec90e1fe458bc4/AB%20536.pdf","has_en":true,"category_counts":{"construction":17,"other":9,"materials":4,"water":2},"category_scores":{"construction":9.03,"other":2.53,"materials":0.5,"water":0.13},"has_zh":true,"lab_locations_zh":[{"name":"LABORATORIUM BADAWCZE MATERIAŁÓW","address":"AB 536 Al. Politechniki 6","city":null,"postal":null},{"name":"Laboratorium Badawcze Materiałów i Konstrukcji Budowlanych","address":"Al. Politechniki 6, 93-590 Łódź","city":"Łódź","postal":"93-590"},{"name":"建筑材料与结构检测实验室；Al. Politechniki 6, 93-590 Łódź","address":null,"city":null,"postal":null}]},"methods":[{"_id":"6a7d7b990636ba417e41bdda","lab_id":"69ad52a3de79e566650fb2b8","country":"PL","accr_number":"AB 536","accr_body":"PCA","test_object":"Beton","methodology":"Wytrzymałość na ściskanie","parameters":[{"name":"Zakres siły","range":"(60 – 2900) kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na ściskanie\nZakres siły (60 – 2900) kN","reference":"PN-EN 12390-3:2019-07","norm_bases":["PN-EN 12390-3:2019-07"],"lab_section":"Laboratorium Badawcze Materiałów i Konstrukcji Budowlanych; Al. Politechniki 6, 93-590 Łódź","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Wytrzymałość na ściskanie\nZakres siły (60 – 2900) kN PN-EN 12390-3:2019-07 Beton Wytrzymalosc na sciskanie\nZakres sily (60 – 2900) kN PN-EN 12390-3:2019-07","categories":["construction"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Building Materials and Structures Testing Laboratory; Al. Politechniki 6, 93-590 Łódź","methodology_en":"Compressive strength","parameters_en":[{"name":"Force range","range":"(60 – 2900) kN"}],"search_en":"Concrete Compressive strength Building Materials and Structures Testing Laboratory; Al. Politechniki 6, 93-590 Łódź Force range PN-EN 12390-3:2019-07","test_object_en":"Concrete","methodology_zh":"抗压强度","parameters_zh":[{"name":"力值范围","range":"(60 – 2900) kN"}],"search_zh":"混凝土 抗压强度 建筑材料与结构检测实验室；Al. Politechniki 6, 93-590 Łódź 力值范围 PN-EN 12390-3:2019-07","test_object_zh":"混凝土","lab_section_zh":"建筑材料与结构检测实验室；Al. Politechniki 6, 93-590 Łódź"},{"_id":"6a7d7b990636ba417e41bddb","lab_id":"69ad52a3de79e566650fb2b8","country":"PL","accr_number":"AB 536","accr_body":"PCA","test_object":"Beton","methodology":"Wytrzymałość na rozciąganie przy rozłupywaniu","parameters":[{"name":"Zakres siły","range":"(60 – 2900) kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na rozciąganie przy rozłupywaniu\nZakres siły (60 – 2900) kN","reference":"PN-EN 12390-6:2024-04","norm_bases":["PN-EN 12390-6:2024-04"],"lab_section":"Laboratorium Badawcze Materiałów i Konstrukcji Budowlanych; Al. Politechniki 6, 93-590 Łódź","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Wytrzymałość na rozciąganie przy rozłupywaniu\nZakres siły (60 – 2900) kN PN-EN 12390-6:2024-04 Beton Wytrzymalosc na rozciaganie przy rozlupywaniu\nZakres sily (60 – 2900) kN PN-EN 12390-6:2024-04","categories":["construction"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Building Materials and Structures Testing Laboratory; Al. Politechniki 6, 93-590 Łódź","methodology_en":"Splitting tensile strength","parameters_en":[{"name":"Force range","range":"(60 – 2900) kN"}],"search_en":"Concrete Splitting tensile strength Building Materials and Structures Testing Laboratory; Al. Politechniki 6, 93-590 Łódź Force range PN-EN 12390-6:2024-04","test_object_en":"Concrete","methodology_zh":"劈裂抗拉强度","parameters_zh":[{"name":"力值范围","range":"(60 – 2900) kN"}],"search_zh":"混凝土 劈裂抗拉强度 建筑材料与结构检测实验室；Al. Politechniki 6, 93-590 Łódź 力值范围 PN-EN 12390-6:2024-04","test_object_zh":"混凝土","lab_section_zh":"建筑材料与结构检测实验室；Al. Politechniki 6, 93-590 Łódź"},{"_id":"6a7d7b990636ba417e41bddc","lab_id":"69ad52a3de79e566650fb2b8","country":"PL","accr_number":"AB 536","accr_body":"PCA","test_object":"Beton","methodology":"Nasiąkliwość","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Nasiąkliwość","reference":"PN-88/B-06250","norm_bases":["PN-88/B-06250"],"lab_section":"Laboratorium Badawcze Materiałów i Konstrukcji Budowlanych; Al. Politechniki 6, 93-590 Łódź","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Nasiąkliwość PN-88/B-06250 Beton Nasiakliwosc PN-88/B-06250","categories":["construction"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Building Materials and Structures Testing Laboratory; Al. Politechniki 6, 93-590 Łódź","methodology_en":"Water absorption","search_en":"Concrete Water absorption Building Materials and Structures Testing Laboratory; Al. Politechniki 6, 93-590 Łódź PN-88/B-06250","test_object_en":"Concrete","methodology_zh":"吸水率","search_zh":"混凝土 吸水率 建筑材料与结构检测实验室；Al. Politechniki 6, 93-590 Łódź PN-88/B-06250","test_object_zh":"混凝土","lab_section_zh":"建筑材料与结构检测实验室；Al. Politechniki 6, 93-590 Łódź"},{"_id":"6a7d7b990636ba417e41bddd","lab_id":"69ad52a3de79e566650fb2b8","country":"PL","accr_number":"AB 536","accr_body":"PCA","test_object":"Beton","methodology":"Przepuszczalność wody, Zakres ciśnienia max 1 MPa","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Przepuszczalność wody, Zakres ciśnienia max 1 MPa","reference":"PN-88/B-06250","norm_bases":["PN-88/B-06250"],"lab_section":"Laboratorium Badawcze Materiałów i Konstrukcji Budowlanych; Al. Politechniki 6, 93-590 Łódź","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Przepuszczalność wody, Zakres ciśnienia max 1 MPa PN-88/B-06250 Beton Przepuszczalnosc wody, Zakres cisnienia max 1 MPa PN-88/B-06250","categories":["water","construction"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Building Materials and Structures Testing Laboratory; Al. Politechniki 6, 93-590 Łódź","methodology_en":"Water permeability, Pressure range max 1 MPa","search_en":"Concrete Water permeability, Pressure range max 1 MPa Building Materials and Structures Testing Laboratory; Al. Politechniki 6, 93-590 Łódź PN-88/B-06250","test_object_en":"Concrete","search_zh":"混凝土 建筑材料与结构检测实验室；Al. Politechniki 6, 93-590 Łódź PN-88/B-06250","test_object_zh":"混凝土","lab_section_zh":"建筑材料与结构检测实验室；Al. Politechniki 6, 93-590 Łódź"},{"_id":"6a7d7b990636ba417e41bdde","lab_id":"69ad52a3de79e566650fb2b8","country":"PL","accr_number":"AB 536","accr_body":"PCA","test_object":"Beton","methodology":"Gęstość","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Gęstość","reference":"PN-EN 12390-7:2019-08","norm_bases":["PN-EN 12390-7:2019-08"],"lab_section":"Laboratorium Badawcze Materiałów i Konstrukcji Budowlanych; Al. Politechniki 6, 93-590 Łódź","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Gęstość PN-EN 12390-7:2019-08 Beton Gestosc PN-EN 12390-7:2019-08","categories":["construction"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Building Materials and Structures Testing Laboratory; Al. Politechniki 6, 93-590 Łódź","methodology_en":"Density","search_en":"Concrete Density Building Materials and Structures Testing Laboratory; Al. Politechniki 6, 93-590 Łódź PN-EN 12390-7:2019-08","test_object_en":"Concrete","methodology_zh":"密度","search_zh":"混凝土 密度 建筑材料与结构检测实验室；Al. Politechniki 6, 93-590 Łódź PN-EN 12390-7:2019-08","test_object_zh":"混凝土","lab_section_zh":"建筑材料与结构检测实验室；Al. Politechniki 6, 93-590 Łódź"},{"_id":"6a7d7b990636ba417e41bddf","lab_id":"69ad52a3de79e566650fb2b8","country":"PL","accr_number":"AB 536","accr_body":"PCA","test_object":"Beton","methodology":"Głębokość penetracji wody pod ciśnieniem","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Głębokość penetracji wody pod ciśnieniem","reference":"PN-EN 12390-8:2019-08","norm_bases":["PN-EN 12390-8:2019-08"],"lab_section":"Laboratorium Badawcze Materiałów i Konstrukcji Budowlanych; Al. Politechniki 6, 93-590 Łódź","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Głębokość penetracji wody pod ciśnieniem PN-EN 12390-8:2019-08 Beton Glebokosc penetracji wody pod cisnieniem PN-EN 12390-8:2019-08","categories":["water","construction"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Building Materials and Structures Testing Laboratory; Al. Politechniki 6, 93-590 Łódź","methodology_en":"Depth of penetration of water under pressure","search_en":"Concrete Depth of penetration of water under pressure Building Materials and Structures Testing Laboratory; Al. Politechniki 6, 93-590 Łódź PN-EN 12390-8:2019-08","test_object_en":"Concrete","methodology_zh":"压力水渗透深度","search_zh":"混凝土 压力水渗透深度 建筑材料与结构检测实验室；Al. Politechniki 6, 93-590 Łódź PN-EN 12390-8:2019-08","test_object_zh":"混凝土","lab_section_zh":"建筑材料与结构检测实验室；Al. Politechniki 6, 93-590 Łódź"},{"_id":"6a7d7b990636ba417e41bde0","lab_id":"69ad52a3de79e566650fb2b8","country":"PL","accr_number":"AB 536","accr_body":"PCA","test_object":"Beton","methodology":"Odporność na działanie mrozu","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na działanie mrozu","reference":"PN-88/B-06250 p. 6.5.1","norm_bases":["PN-88/B-06250 p. 6.5.1"],"lab_section":"Laboratorium Badawcze Materiałów i Konstrukcji Budowlanych; Al. Politechniki 6, 93-590 Łódź","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Odporność na działanie mrozu PN-88/B-06250 p. 6.5.1 Beton Odpornosc na dzialanie mrozu PN-88/B-06250 p. 6.5.1","categories":["construction"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Building Materials and Structures Testing Laboratory; Al. Politechniki 6, 93-590 Łódź","methodology_en":"Resistance to freezing","search_en":"Concrete Resistance to freezing Building Materials and Structures Testing Laboratory; Al. Politechniki 6, 93-590 Łódź PN-88/B-06250 p. 6.5.1","test_object_en":"Concrete","methodology_zh":"抗冻性","search_zh":"混凝土 抗冻性 建筑材料与结构检测实验室；Al. Politechniki 6, 93-590 Łódź PN-88/B-06250 p. 6.5.1","test_object_zh":"混凝土","lab_section_zh":"建筑材料与结构检测实验室；Al. Politechniki 6, 93-590 Łódź"},{"_id":"6a7d7b990636ba417e41bde1","lab_id":"69ad52a3de79e566650fb2b8","country":"PL","accr_number":"AB 536","accr_body":"PCA","test_object":"Kamień naturalny","methodology":"Ścieralność, Środek pasa ścierania promień r = 220 mm","parameters":[],"technique":"Metoda B tarczy Boehmego","techniques":["Metoda B tarczy Boehmego"],"computed":[],"activity":"Ścieralność, Środek pasa ścierania promień r = 220 mm\nMetoda B tarczy Boehmego","reference":"PN-EN 14157:2017-11","norm_bases":["PN-EN 14157:2017-11"],"lab_section":"Laboratorium Badawcze Materiałów i Konstrukcji Budowlanych; Al. Politechniki 6, 93-590 Łódź","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kamień naturalny Ścieralność, Środek pasa ścierania promień r = 220 mm\nMetoda B tarczy Boehmego PN-EN 14157:2017-11 Kamien naturalny Scieralnosc, Srodek pasa scierania promien r = 220 mm\nMetoda B tarczy Boehmego PN-EN 14157:2017-11","categories":["other"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Building Materials and Structures Testing Laboratory; Al. Politechniki 6, 93-590 Łódź","methodology_en":"Abrasion resistance, Centre of the abrasion track radius r = 220 mm","search_en":"Natural stone Abrasion resistance, Centre of the abrasion track radius r = 220 mm Method B, Böhme disc Building Materials and Structures Testing Laboratory; Al. Politechniki 6, 93-590 Łódź PN-EN 14157:2017-11","technique_en":"Method B, Böhme disc","test_object_en":"Natural stone","lab_section_zh":"建筑材料与结构检测实验室；Al. Politechniki 6, 93-590 Łódź","search_zh":"天然石材 磨耗性，磨耗带中心半径 r = 220 mm 建筑材料与结构检测实验室；Al. Politechniki 6, 93-590 Łódź PN-EN 14157:2017-11","test_object_zh":"天然石材","methodology_zh":"磨耗性，磨耗带中心半径 r = 220 mm"},{"_id":"6a7d7b990636ba417e41bde2","lab_id":"69ad52a3de79e566650fb2b8","country":"PL","accr_number":"AB 536","accr_body":"PCA","test_object":"Beton w konstrukcji","methodology":"Wytrzymałość na ściskanie odwiertów rdzeniowych","parameters":[{"name":"Zakres siły","range":"(60 – 2900) kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na ściskanie odwiertów rdzeniowych\nZakres siły (60 – 2900) kN","reference":"PN-EN 12504-1:2019-08+AC:2021-01 | PN-EN 12390-3:2019-07","norm_bases":["PN-EN 12504-1:2019-08+AC:2021-01","PN-EN 12390-3:2019-07"],"lab_section":"Laboratorium Badawcze Materiałów i Konstrukcji Budowlanych; Al. Politechniki 6, 93-590 Łódź","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton w konstrukcji Wytrzymałość na ściskanie odwiertów rdzeniowych\nZakres siły (60 – 2900) kN PN-EN 12504-1:2019-08+AC:2021-01 | PN-EN 12390-3:2019-07 Beton w konstrukcji Wytrzymalosc na sciskanie odwiertow rdzeniowych\nZakres sily (60 – 2900) kN PN-EN 12504-1:2019-08+AC:2021-01 | PN-EN 12390-3:2019-07","categories":["construction"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Building Materials and Structures Testing Laboratory; Al. Politechniki 6, 93-590 Łódź","methodology_en":"Compressive strength of drilled cores","parameters_en":[{"name":"Force range","range":"(60 – 2900) kN"}],"search_en":"Concrete in structures Compressive strength of drilled cores Building Materials and Structures Testing Laboratory; Al. Politechniki 6, 93-590 Łódź Force range PN-EN 12504-1:2019-08+AC:2021-01 | PN-EN 12390-3:2019-07","test_object_en":"Concrete in structures","parameters_zh":[{"name":"力值范围","range":"(60 – 2900) kN"}],"search_zh":"结构中的混凝土 建筑材料与结构检测实验室；Al. Politechniki 6, 93-590 Łódź 力值范围 PN-EN 12504-1:2019-08+AC:2021-01 | PN-EN 12390-3:2019-07","lab_section_zh":"建筑材料与结构检测实验室；Al. Politechniki 6, 93-590 Łódź","test_object_zh":"结构中的混凝土"},{"_id":"6a7d7b990636ba417e41bde3","lab_id":"69ad52a3de79e566650fb2b8","country":"PL","accr_number":"AB 536","accr_body":"PCA","test_object":"Beton w konstrukcji","methodology":"Pobieranie odwiertów rdzeniowych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie odwiertów rdzeniowych","reference":"PN-EN 12504-1:2019-08+AC:2021-01","norm_bases":["PN-EN 12504-1:2019-08+AC:2021-01"],"lab_section":"Laboratorium Badawcze Materiałów i Konstrukcji Budowlanych; Al. Politechniki 6, 93-590 Łódź","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton w konstrukcji Pobieranie odwiertów rdzeniowych PN-EN 12504-1:2019-08+AC:2021-01 Beton w konstrukcji Pobieranie odwiertow rdzeniowych PN-EN 12504-1:2019-08+AC:2021-01","categories":["construction"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Building Materials and Structures Testing Laboratory; Al. Politechniki 6, 93-590 Łódź","methodology_en":"Taking core drill samples","search_en":"Concrete in structures Taking core drill samples Building Materials and Structures Testing Laboratory; Al. Politechniki 6, 93-590 Łódź PN-EN 12504-1:2019-08+AC:2021-01","test_object_en":"Concrete in structures","lab_section_zh":"建筑材料与结构检测实验室；Al. Politechniki 6, 93-590 Łódź","search_zh":"结构中的混凝土 建筑材料与结构检测实验室；Al. Politechniki 6, 93-590 Łódź PN-EN 12504-1:2019-08+AC:2021-01","test_object_zh":"结构中的混凝土"},{"_id":"6a7d7b990636ba417e41bde4","lab_id":"69ad52a3de79e566650fb2b8","country":"PL","accr_number":"AB 536","accr_body":"PCA","test_object":"Kostka brukowa","methodology":"Nasiąkliwość","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Nasiąkliwość","reference":"PN-EN 1338:2005 zał. E +AC:2007","norm_bases":["PN-EN 1338:2005 zał. E +AC:2007"],"lab_section":"Laboratorium Badawcze Materiałów i Konstrukcji Budowlanych; Al. Politechniki 6, 93-590 Łódź","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kostka brukowa Nasiąkliwość PN-EN 1338:2005 zał. E +AC:2007 Kostka brukowa Nasiakliwosc PN-EN 1338:2005 zal. E +AC:2007","categories":["other"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Building Materials and Structures Testing Laboratory; Al. Politechniki 6, 93-590 Łódź","methodology_en":"Water absorption","search_en":"Paving blocks Water absorption Building Materials and Structures Testing Laboratory; Al. Politechniki 6, 93-590 Łódź PN-EN 1338:2005 zał. E +AC:2007","test_object_en":"Paving blocks","methodology_zh":"吸水率","search_zh":"吸水率 建筑材料与结构检测实验室；Al. Politechniki 6, 93-590 Łódź PN-EN 1338:2005 zał. E +AC:2007","lab_section_zh":"建筑材料与结构检测实验室；Al. Politechniki 6, 93-590 Łódź"},{"_id":"6a7d7b990636ba417e41bde5","lab_id":"69ad52a3de79e566650fb2b8","country":"PL","accr_number":"AB 536","accr_body":"PCA","test_object":"Płyty brukowe","methodology":"Nasiąkliwość","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Nasiąkliwość","reference":"PN-EN 1339:2005 zał. E+AC:2007","norm_bases":["PN-EN 1339:2005 zał. E+AC:2007"],"lab_section":"Laboratorium Badawcze Materiałów i Konstrukcji Budowlanych; Al. Politechniki 6, 93-590 Łódź","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Płyty brukowe Nasiąkliwość PN-EN 1339:2005 zał. E+AC:2007 Plyty brukowe Nasiakliwosc PN-EN 1339:2005 zal. E+AC:2007","categories":["other"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Building Materials and Structures Testing Laboratory; Al. Politechniki 6, 93-590 Łódź","methodology_en":"Water absorption","search_en":"Paving flags Water absorption Building Materials and Structures Testing Laboratory; Al. Politechniki 6, 93-590 Łódź PN-EN 1339:2005 zał. E+AC:2007","test_object_en":"Paving flags","methodology_zh":"吸水率","search_zh":"吸水率 建筑材料与结构检测实验室；Al. Politechniki 6, 93-590 Łódź PN-EN 1339:2005 zał. E+AC:2007","lab_section_zh":"建筑材料与结构检测实验室；Al. Politechniki 6, 93-590 Łódź"},{"_id":"6a7d7b990636ba417e41bde6","lab_id":"69ad52a3de79e566650fb2b8","country":"PL","accr_number":"AB 536","accr_body":"PCA","test_object":"Krawężniki","methodology":"Nasiąkliwość","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Nasiąkliwość","reference":"PN-EN 1340:2004 zał. E+AC:2007","norm_bases":["PN-EN 1340:2004 zał. E+AC:2007"],"lab_section":"Laboratorium Badawcze Materiałów i Konstrukcji Budowlanych; Al. Politechniki 6, 93-590 Łódź","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Krawężniki Nasiąkliwość PN-EN 1340:2004 zał. E+AC:2007 Krawezniki Nasiakliwosc PN-EN 1340:2004 zal. E+AC:2007","categories":["other"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Building Materials and Structures Testing Laboratory; Al. Politechniki 6, 93-590 Łódź","methodology_en":"Water absorption","search_en":"Kerbs Water absorption Building Materials and Structures Testing Laboratory; Al. Politechniki 6, 93-590 Łódź PN-EN 1340:2004 zał. E+AC:2007","test_object_en":"Kerbs","methodology_zh":"吸水率","search_zh":"路缘石 吸水率 建筑材料与结构检测实验室；Al. Politechniki 6, 93-590 Łódź PN-EN 1340:2004 zał. E+AC:2007","lab_section_zh":"建筑材料与结构检测实验室；Al. Politechniki 6, 93-590 Łódź","test_object_zh":"路缘石"},{"_id":"6a7d7b990636ba417e41bde7","lab_id":"69ad52a3de79e566650fb2b8","country":"PL","accr_number":"AB 536","accr_body":"PCA","test_object":"Betonowe rury i kształtki","methodology":"Nasiąkliwość","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Nasiąkliwość","reference":"PN-EN 1916:2005 zał. F+AC:2009","norm_bases":["PN-EN 1916:2005 zał. F+AC:2009"],"lab_section":"Laboratorium Badawcze Materiałów i Konstrukcji Budowlanych; Al. Politechniki 6, 93-590 Łódź","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Betonowe rury i kształtki Nasiąkliwość PN-EN 1916:2005 zał. F+AC:2009 Betonowe rury i ksztaltki Nasiakliwosc PN-EN 1916:2005 zal. F+AC:2009","categories":["construction"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Building Materials and Structures Testing Laboratory; Al. Politechniki 6, 93-590 Łódź","methodology_en":"Water absorption","search_en":"Concrete pipes and fittings Water absorption Building Materials and Structures Testing Laboratory; Al. Politechniki 6, 93-590 Łódź PN-EN 1916:2005 zał. F+AC:2009","test_object_en":"Concrete pipes and fittings","methodology_zh":"吸水率","search_zh":"吸水率 建筑材料与结构检测实验室；Al. Politechniki 6, 93-590 Łódź PN-EN 1916:2005 zał. F+AC:2009","lab_section_zh":"建筑材料与结构检测实验室；Al. Politechniki 6, 93-590 Łódź"},{"_id":"6a7d7b990636ba417e41bde8","lab_id":"69ad52a3de79e566650fb2b8","country":"PL","accr_number":"AB 536","accr_body":"PCA","test_object":"Betonowe elementy studzienek","methodology":"Nasiąkliwość","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Nasiąkliwość","reference":"PN-EN 1917:2004 zał. D+AC:2009","norm_bases":["PN-EN 1917:2004 zał. D+AC:2009"],"lab_section":"Laboratorium Badawcze Materiałów i Konstrukcji Budowlanych; Al. Politechniki 6, 93-590 Łódź","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Betonowe elementy studzienek Nasiąkliwość PN-EN 1917:2004 zał. D+AC:2009 Betonowe elementy studzienek Nasiakliwosc PN-EN 1917:2004 zal. D+AC:2009","categories":["construction"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Building Materials and Structures Testing Laboratory; Al. Politechniki 6, 93-590 Łódź","methodology_en":"Water absorption","search_en":"Concrete manhole components Water absorption Building Materials and Structures Testing Laboratory; Al. Politechniki 6, 93-590 Łódź PN-EN 1917:2004 zał. D+AC:2009","test_object_en":"Concrete manhole components","methodology_zh":"吸水率","search_zh":"吸水率 建筑材料与结构检测实验室；Al. Politechniki 6, 93-590 Łódź PN-EN 1917:2004 zał. D+AC:2009","lab_section_zh":"建筑材料与结构检测实验室；Al. Politechniki 6, 93-590 Łódź"},{"_id":"6a7d7b990636ba417e41bde9","lab_id":"69ad52a3de79e566650fb2b8","country":"PL","accr_number":"AB 536","accr_body":"PCA","test_object":"Kostka brukowa","methodology":"Ścieralność, Środek pasa ścierania promień r = 220 mm","parameters":[],"technique":"Metoda: tarczy Boehmego","techniques":["Metoda: tarczy Boehmego"],"computed":[],"activity":"Ścieralność, Środek pasa ścierania promień r = 220 mm\nMetoda: tarczy Boehmego","reference":"PN-EN 1338: 2005 zał. H+AC:2007","norm_bases":["PN-EN 1338: 2005 zał. H+AC:2007"],"lab_section":"Laboratorium Badawcze Materiałów i Konstrukcji Budowlanych; Al. Politechniki 6, 93-590 Łódź","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kostka brukowa Ścieralność, Środek pasa ścierania promień r = 220 mm\nMetoda: tarczy Boehmego PN-EN 1338: 2005 zał. H+AC:2007 Kostka brukowa Scieralnosc, Srodek pasa scierania promien r = 220 mm\nMetoda: tarczy Boehmego PN-EN 1338: 2005 zal. H+AC:2007","categories":["other"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Building Materials and Structures Testing Laboratory; Al. Politechniki 6, 93-590 Łódź","methodology_en":"Abrasion resistance, Centre of the abrasion track radius r = 220 mm","search_en":"Paving blocks Abrasion resistance, Centre of the abrasion track radius r = 220 mm Method: Böhme disc Building Materials and Structures Testing Laboratory; Al. Politechniki 6, 93-590 Łódź PN-EN 1338: 2005 zał. H+AC:2007","technique_en":"Method: Böhme disc","test_object_en":"Paving blocks","lab_section_zh":"建筑材料与结构检测实验室；Al. Politechniki 6, 93-590 Łódź","search_zh":"磨耗性，磨耗带中心半径 r = 220 mm 方法：伯姆磨盘法 建筑材料与结构检测实验室；Al. Politechniki 6, 93-590 Łódź PN-EN 1338: 2005 zał. H+AC:2007","methodology_zh":"磨耗性，磨耗带中心半径 r = 220 mm","technique_zh":"方法：伯姆磨盘法"},{"_id":"6a7d7b990636ba417e41bdea","lab_id":"69ad52a3de79e566650fb2b8","country":"PL","accr_number":"AB 536","accr_body":"PCA","test_object":"Płyty brukowe","methodology":"Ścieralność, Środek pasa ścierania promień r = 220 mm","parameters":[],"technique":"Metoda: tarczy Boehmego","techniques":["Metoda: tarczy Boehmego"],"computed":[],"activity":"Ścieralność, Środek pasa ścierania promień r = 220 mm\nMetoda: tarczy Boehmego","reference":"PN-EN 1339: 2005 zał. H+AC:2007","norm_bases":["PN-EN 1339: 2005 zał. H+AC:2007"],"lab_section":"Laboratorium Badawcze Materiałów i Konstrukcji Budowlanych; Al. Politechniki 6, 93-590 Łódź","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Płyty brukowe Ścieralność, Środek pasa ścierania promień r = 220 mm\nMetoda: tarczy Boehmego PN-EN 1339: 2005 zał. H+AC:2007 Plyty brukowe Scieralnosc, Srodek pasa scierania promien r = 220 mm\nMetoda: tarczy Boehmego PN-EN 1339: 2005 zal. H+AC:2007","categories":["other"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Building Materials and Structures Testing Laboratory; Al. Politechniki 6, 93-590 Łódź","methodology_en":"Abrasion resistance, Centre of the abrasion track radius r = 220 mm","search_en":"Paving flags Abrasion resistance, Centre of the abrasion track radius r = 220 mm Method: Böhme disc Building Materials and Structures Testing Laboratory; Al. Politechniki 6, 93-590 Łódź PN-EN 1339: 2005 zał. H+AC:2007","technique_en":"Method: Böhme disc","test_object_en":"Paving flags","lab_section_zh":"建筑材料与结构检测实验室；Al. Politechniki 6, 93-590 Łódź","search_zh":"磨耗性，磨耗带中心半径 r = 220 mm 方法：伯姆磨盘法 建筑材料与结构检测实验室；Al. Politechniki 6, 93-590 Łódź PN-EN 1339: 2005 zał. H+AC:2007","methodology_zh":"磨耗性，磨耗带中心半径 r = 220 mm","technique_zh":"方法：伯姆磨盘法"},{"_id":"6a7d7b990636ba417e41bdeb","lab_id":"69ad52a3de79e566650fb2b8","country":"PL","accr_number":"AB 536","accr_body":"PCA","test_object":"Krawężniki","methodology":"Ścieralność, Środek pasa ścierania promień r = 220 mm","parameters":[],"technique":"Metoda: tarczy Boehmego","techniques":["Metoda: tarczy Boehmego"],"computed":[],"activity":"Ścieralność, Środek pasa ścierania promień r = 220 mm\nMetoda: tarczy Boehmego","reference":"PN-EN 1340: 2004 zał. H+AC:2007","norm_bases":["PN-EN 1340: 2004 zał. H+AC:2007"],"lab_section":"Laboratorium Badawcze Materiałów i Konstrukcji Budowlanych; Al. Politechniki 6, 93-590 Łódź","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Krawężniki Ścieralność, Środek pasa ścierania promień r = 220 mm\nMetoda: tarczy Boehmego PN-EN 1340: 2004 zał. H+AC:2007 Krawezniki Scieralnosc, Srodek pasa scierania promien r = 220 mm\nMetoda: tarczy Boehmego PN-EN 1340: 2004 zal. H+AC:2007","categories":["other"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Building Materials and Structures Testing Laboratory; Al. Politechniki 6, 93-590 Łódź","methodology_en":"Abrasion resistance, Centre of the abrasion track radius r = 220 mm","search_en":"Kerbs Abrasion resistance, Centre of the abrasion track radius r = 220 mm Method: Böhme disc Building Materials and Structures Testing Laboratory; Al. Politechniki 6, 93-590 Łódź PN-EN 1340: 2004 zał. H+AC:2007","technique_en":"Method: Böhme disc","test_object_en":"Kerbs","lab_section_zh":"建筑材料与结构检测实验室；Al. Politechniki 6, 93-590 Łódź","search_zh":"路缘石 磨耗性，磨耗带中心半径 r = 220 mm 方法：伯姆磨盘法 建筑材料与结构检测实验室；Al. Politechniki 6, 93-590 Łódź PN-EN 1340: 2004 zał. H+AC:2007","test_object_zh":"路缘石","methodology_zh":"磨耗性，磨耗带中心半径 r = 220 mm","technique_zh":"方法：伯姆磨盘法"},{"_id":"6a7d7b990636ba417e41bdec","lab_id":"69ad52a3de79e566650fb2b8","country":"PL","accr_number":"AB 536","accr_body":"PCA","test_object":"Podkłady podłogowe","methodology":"Ścieralność, Środek pasa ścierania promień r = 220 mm","parameters":[],"technique":"Metoda: tarczy Boehmego","techniques":["Metoda: tarczy Boehmego"],"computed":[],"activity":"Ścieralność, Środek pasa ścierania promień r = 220 mm\nMetoda: tarczy Boehmego","reference":"PN-EN 13892-3:2015-02","norm_bases":["PN-EN 13892-3:2015-02"],"lab_section":"Laboratorium Badawcze Materiałów i Konstrukcji Budowlanych; Al. Politechniki 6, 93-590 Łódź","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Podkłady podłogowe Ścieralność, Środek pasa ścierania promień r = 220 mm\nMetoda: tarczy Boehmego PN-EN 13892-3:2015-02 Podklady podlogowe Scieralnosc, Srodek pasa scierania promien r = 220 mm\nMetoda: tarczy Boehmego PN-EN 13892-3:2015-02","categories":["other"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Building Materials and Structures Testing Laboratory; Al. Politechniki 6, 93-590 Łódź","methodology_en":"Abrasion resistance, Centre of the abrasion track radius r = 220 mm","search_en":"Floor screeds Abrasion resistance, Centre of the abrasion track radius r = 220 mm Method: Böhme disc Building Materials and Structures Testing Laboratory; Al. Politechniki 6, 93-590 Łódź PN-EN 13892-3:2015-02","technique_en":"Method: Böhme disc","test_object_en":"Floor screeds","lab_section_zh":"建筑材料与结构检测实验室；Al. Politechniki 6, 93-590 Łódź","search_zh":"地面找平层 磨耗性，磨耗带中心半径 r = 220 mm 方法：伯姆磨盘法 建筑材料与结构检测实验室；Al. Politechniki 6, 93-590 Łódź PN-EN 13892-3:2015-02","test_object_zh":"地面找平层","methodology_zh":"磨耗性，磨耗带中心半径 r = 220 mm","technique_zh":"方法：伯姆磨盘法"},{"_id":"6a7d7b990636ba417e41bded","lab_id":"69ad52a3de79e566650fb2b8","country":"PL","accr_number":"AB 536","accr_body":"PCA","test_object":"Cement","methodology":"Wytrzymałości na zginanie","parameters":[{"name":"Zakres siły","range":"(1 – 8) kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałości na zginanie\nZakres siły (1 – 8) kN","reference":"PN-EN 196-1:2016-07","norm_bases":["PN-EN 196-1:2016-07"],"lab_section":"Laboratorium Badawcze Materiałów i Konstrukcji Budowlanych; Al. Politechniki 6, 93-590 Łódź","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Cement Wytrzymałości na zginanie\nZakres siły (1 – 8) kN PN-EN 196-1:2016-07 Cement Wytrzymalosci na zginanie\nZakres sily (1 – 8) kN PN-EN 196-1:2016-07","categories":["construction"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Building Materials and Structures Testing Laboratory; Al. Politechniki 6, 93-590 Łódź","methodology_en":"Flexural strengths","parameters_en":[{"name":"Force range","range":"(1 – 8) kN"}],"search_en":"Cement Flexural strengths Building Materials and Structures Testing Laboratory; Al. Politechniki 6, 93-590 Łódź Force range PN-EN 196-1:2016-07","test_object_en":"Cement","parameters_zh":[{"name":"力值范围","range":"(1 – 8) kN"}],"search_zh":"水泥 建筑材料与结构检测实验室；Al. Politechniki 6, 93-590 Łódź 力值范围 PN-EN 196-1:2016-07","test_object_zh":"水泥","lab_section_zh":"建筑材料与结构检测实验室；Al. Politechniki 6, 93-590 Łódź"},{"_id":"6a7d7b990636ba417e41bdee","lab_id":"69ad52a3de79e566650fb2b8","country":"PL","accr_number":"AB 536","accr_body":"PCA","test_object":"Cement","methodology":"Wytrzymałości na ściskanie","parameters":[{"name":"Zakres siły","range":"(10-200) kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałości na ściskanie\nZakres siły (10-200) kN","reference":"PN-EN 196-1:2016-07","norm_bases":["PN-EN 196-1:2016-07"],"lab_section":"Laboratorium Badawcze Materiałów i Konstrukcji Budowlanych; Al. Politechniki 6, 93-590 Łódź","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Cement Wytrzymałości na ściskanie\nZakres siły (10-200) kN PN-EN 196-1:2016-07 Cement Wytrzymalosci na sciskanie\nZakres sily (10-200) kN PN-EN 196-1:2016-07","categories":["construction"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Building Materials and Structures Testing Laboratory; Al. Politechniki 6, 93-590 Łódź","methodology_en":"Compressive strengths","parameters_en":[{"name":"Force range","range":"(10-200) kN"}],"search_en":"Cement Compressive strengths Building Materials and Structures Testing Laboratory; Al. Politechniki 6, 93-590 Łódź Force range PN-EN 196-1:2016-07","test_object_en":"Cement","parameters_zh":[{"name":"力值范围","range":"(10-200) kN"}],"search_zh":"水泥 建筑材料与结构检测实验室；Al. Politechniki 6, 93-590 Łódź 力值范围 PN-EN 196-1:2016-07","test_object_zh":"水泥","lab_section_zh":"建筑材料与结构检测实验室；Al. Politechniki 6, 93-590 Łódź"},{"_id":"6a7d7b990636ba417e41bdef","lab_id":"69ad52a3de79e566650fb2b8","country":"PL","accr_number":"AB 536","accr_body":"PCA","test_object":"Cement","methodology":"Czas wiązania","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Czas wiązania","reference":"PN-EN 196-3:2016-12","norm_bases":["PN-EN 196-3:2016-12"],"lab_section":"Laboratorium Badawcze Materiałów i Konstrukcji Budowlanych; Al. Politechniki 6, 93-590 Łódź","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Cement Czas wiązania PN-EN 196-3:2016-12 Cement Czas wiazania PN-EN 196-3:2016-12","categories":["construction"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Building Materials and Structures Testing Laboratory; Al. Politechniki 6, 93-590 Łódź","methodology_en":"Setting time","search_en":"Cement Setting time Building Materials and Structures Testing Laboratory; Al. Politechniki 6, 93-590 Łódź PN-EN 196-3:2016-12","test_object_en":"Cement","search_zh":"水泥 凝结时间 建筑材料与结构检测实验室；Al. Politechniki 6, 93-590 Łódź PN-EN 196-3:2016-12","test_object_zh":"水泥","lab_section_zh":"建筑材料与结构检测实验室；Al. Politechniki 6, 93-590 Łódź","methodology_zh":"凝结时间"},{"_id":"6a7d7b990636ba417e41bdf0","lab_id":"69ad52a3de79e566650fb2b8","country":"PL","accr_number":"AB 536","accr_body":"PCA","test_object":"Cement","methodology":"Stałość objętości","parameters":[],"technique":"Metoda: Le Chateliera","techniques":["Metoda: Le Chateliera"],"computed":[],"activity":"Stałość objętości\nMetoda: Le Chateliera","reference":"PN-EN 196-3:2016-12","norm_bases":["PN-EN 196-3:2016-12"],"lab_section":"Laboratorium Badawcze Materiałów i Konstrukcji Budowlanych; Al. Politechniki 6, 93-590 Łódź","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Cement Stałość objętości\nMetoda: Le Chateliera PN-EN 196-3:2016-12 Cement Stalosc objetosci\nMetoda: Le Chateliera PN-EN 196-3:2016-12","categories":["construction"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Building Materials and Structures Testing Laboratory; Al. Politechniki 6, 93-590 Łódź","methodology_en":"Soundness","search_en":"Cement Soundness Method: Le Chatelier Building Materials and Structures Testing Laboratory; Al. Politechniki 6, 93-590 Łódź PN-EN 196-3:2016-12","technique_en":"Method: Le Chatelier","test_object_en":"Cement","search_zh":"水泥 体积安定性 建筑材料与结构检测实验室；Al. Politechniki 6, 93-590 Łódź PN-EN 196-3:2016-12","test_object_zh":"水泥","lab_section_zh":"建筑材料与结构检测实验室；Al. Politechniki 6, 93-590 Łódź","methodology_zh":"体积安定性"},{"_id":"6a7d7b990636ba417e41bdf1","lab_id":"69ad52a3de79e566650fb2b8","country":"PL","accr_number":"AB 536","accr_body":"PCA","test_object":"Kostka brukowa","methodology":"Wytrzymałość na rozciąganie przy rozłupywaniu","parameters":[{"name":"Zakres siły","range":"(100 – 2900) kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na rozciąganie przy rozłupywaniu\nZakres siły (100 – 2900) kN","reference":"PN-EN 1338:2005 zał. F + AC:2007","norm_bases":["PN-EN 1338:2005 zał. F + AC:2007"],"lab_section":"Laboratorium Badawcze Materiałów i Konstrukcji Budowlanych; Al. Politechniki 6, 93-590 Łódź","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kostka brukowa Wytrzymałość na rozciąganie przy rozłupywaniu\nZakres siły (100 – 2900) kN PN-EN 1338:2005 zał. F + AC:2007 Kostka brukowa Wytrzymalosc na rozciaganie przy rozlupywaniu\nZakres sily (100 – 2900) kN PN-EN 1338:2005 zal. F + AC:2007","categories":["other"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Building Materials and Structures Testing Laboratory; Al. Politechniki 6, 93-590 Łódź","methodology_en":"Splitting tensile strength","parameters_en":[{"name":"Force range","range":"(100 – 2900) kN"}],"search_en":"Paving blocks Splitting tensile strength Building Materials and Structures Testing Laboratory; Al. Politechniki 6, 93-590 Łódź Force range PN-EN 1338:2005 zał. F + AC:2007","test_object_en":"Paving blocks","methodology_zh":"劈裂抗拉强度","parameters_zh":[{"name":"力值范围","range":"(100 – 2900) kN"}],"search_zh":"劈裂抗拉强度 建筑材料与结构检测实验室；Al. Politechniki 6, 93-590 Łódź 力值范围 PN-EN 1338:2005 zał. F + AC:2007","lab_section_zh":"建筑材料与结构检测实验室；Al. Politechniki 6, 93-590 Łódź"},{"_id":"6a7d7b990636ba417e41bdf2","lab_id":"69ad52a3de79e566650fb2b8","country":"PL","accr_number":"AB 536","accr_body":"PCA","test_object":"Stal dla budownictwa","methodology":"Granica plastyczności Wytrzymałość na rozciąganie Wydłużenie","parameters":[{"name":"Zakres siły","range":"(6 – 600) kN"}],"technique":"Metoda: Statyczna próba rozciągania w temperaturze pokojowej","techniques":["Metoda: Statyczna próba rozciągania w temperaturze pokojowej"],"computed":[],"activity":"Granica plastyczności Wytrzymałość na rozciąganie Wydłużenie\nZakres siły (6 – 600) kN\nMetoda: Statyczna próba rozciągania w temperaturze pokojowej","reference":"PN-EN ISO 6892-1:2020-05","norm_bases":["PN-EN ISO 6892-1:2020-05"],"lab_section":"Laboratorium Badawcze Materiałów i Konstrukcji Budowlanych; Al. Politechniki 6, 93-590 Łódź","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Stal dla budownictwa Granica plastyczności Wytrzymałość na rozciąganie Wydłużenie\nZakres siły (6 – 600) kN\nMetoda: Statyczna próba rozciągania w temperaturze pokojowej PN-EN ISO 6892-1:2020-05 Stal dla budownictwa Granica plastycznosci Wytrzymalosc na rozciaganie Wydluzenie\nZakres sily (6 – 600) kN\nMetoda: Statyczna proba rozciagania w temperaturze pokojowej PN-EN ISO 6892-1:2020-05","categories":["materials"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Building Materials and Structures Testing Laboratory; Al. Politechniki 6, 93-590 Łódź","methodology_en":"Yield strength Tensile strength Elongation","parameters_en":[{"name":"Force range","range":"(6 – 600) kN"}],"search_en":"Steel for construction Yield strength Tensile strength Elongation Method: Static tensile test at room temperature Building Materials and Structures Testing Laboratory; Al. Politechniki 6, 93-590 Łódź Force range PN-EN ISO 6892-1:2020-05","technique_en":"Method: Static tensile test at room temperature","test_object_en":"Steel for construction","parameters_zh":[{"name":"力值范围","range":"(6 – 600) kN"}],"search_zh":"建筑材料与结构检测实验室；Al. Politechniki 6, 93-590 Łódź 力值范围 PN-EN ISO 6892-1:2020-05","lab_section_zh":"建筑材料与结构检测实验室；Al. Politechniki 6, 93-590 Łódź"},{"_id":"6a7d7b990636ba417e41bdf3","lab_id":"69ad52a3de79e566650fb2b8","country":"PL","accr_number":"AB 536","accr_body":"PCA","test_object":"Stal dla budownictwa","methodology":"Zginanie, Podatność do odkształceń plastycznych","parameters":[],"technique":"Metoda: zginania z podporami","techniques":["Metoda: zginania z podporami"],"computed":[],"activity":"Zginanie, Podatność do odkształceń plastycznych\nMetoda: zginania z podporami","reference":"PN-EN ISO 7438:2021-04","norm_bases":["PN-EN ISO 7438:2021-04"],"lab_section":"Laboratorium Badawcze Materiałów i Konstrukcji Budowlanych; Al. Politechniki 6, 93-590 Łódź","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Stal dla budownictwa Zginanie, Podatność do odkształceń plastycznych\nMetoda: zginania z podporami PN-EN ISO 7438:2021-04 Stal dla budownictwa Zginanie, Podatnosc do odksztalcen plastycznych\nMetoda: zginania z podporami PN-EN ISO 7438:2021-04","categories":["materials"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Building Materials and Structures Testing Laboratory; Al. Politechniki 6, 93-590 Łódź","methodology_en":"Bending, Susceptibility to plastic deformation","search_en":"Steel for construction Bending, Susceptibility to plastic deformation Method: bending with supports Building Materials and Structures Testing Laboratory; Al. Politechniki 6, 93-590 Łódź PN-EN ISO 7438:2021-04","technique_en":"Method: bending with supports","test_object_en":"Steel for construction","lab_section_zh":"建筑材料与结构检测实验室；Al. Politechniki 6, 93-590 Łódź","search_zh":"建筑材料与结构检测实验室；Al. Politechniki 6, 93-590 Łódź PN-EN ISO 7438:2021-04"},{"_id":"6a7d7b990636ba417e41bdf4","lab_id":"69ad52a3de79e566650fb2b8","country":"PL","accr_number":"AB 536","accr_body":"PCA","test_object":"Pręty kompozytowe do zbrojenia betonu","methodology":"Wytrzymałość na rozciąganie","parameters":[{"name":"Zakres siły","range":"(6 – 600) kN"}],"technique":"Metoda: statyczna próba rozciągania","techniques":["Metoda: statyczna próba rozciągania"],"computed":[],"activity":"Wytrzymałość na rozciąganie\nZakres siły (6 – 600) kN\nMetoda: statyczna próba rozciągania","reference":"ISO 10406-1 Edition 2 2015 pkt.6","norm_bases":["ISO 10406-1 Edition 2 2015 pkt.6"],"lab_section":"Laboratorium Badawcze Materiałów i Konstrukcji Budowlanych; Al. Politechniki 6, 93-590 Łódź","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pręty kompozytowe do zbrojenia betonu Wytrzymałość na rozciąganie\nZakres siły (6 – 600) kN\nMetoda: statyczna próba rozciągania ISO 10406-1 Edition 2 2015 pkt.6 Prety kompozytowe do zbrojenia betonu Wytrzymalosc na rozciaganie\nZakres sily (6 – 600) kN\nMetoda: statyczna proba rozciagania ISO 10406-1 Edition 2 2015 pkt.6","categories":["construction","materials"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Building Materials and Structures Testing Laboratory; Al. Politechniki 6, 93-590 Łódź","methodology_en":"Tensile strength","parameters_en":[{"name":"Force range","range":"(6 – 600) kN"}],"search_en":"Composite bars for concrete reinforcement Tensile strength Method: static tensile test Building Materials and Structures Testing Laboratory; Al. Politechniki 6, 93-590 Łódź Force range ISO 10406-1 Edition 2 2015 pkt.6","technique_en":"Method: static tensile test","test_object_en":"Composite bars for concrete reinforcement","parameters_zh":[{"name":"力值范围","range":"(6 – 600) kN"}],"search_zh":"抗拉强度 方法：静态拉伸试验 建筑材料与结构检测实验室；Al. Politechniki 6, 93-590 Łódź 力值范围 ISO 10406-1 Edition 2 2015 pkt.6","lab_section_zh":"建筑材料与结构检测实验室；Al. Politechniki 6, 93-590 Łódź","methodology_zh":"抗拉强度","technique_zh":"方法：静态拉伸试验"},{"_id":"6a7d7b990636ba417e41bdf5","lab_id":"69ad52a3de79e566650fb2b8","country":"PL","accr_number":"AB 536","accr_body":"PCA","test_object":"Pręty kompozytowe do zbrojenia betonu","methodology":"Moduł sprężystości przy rozciąganiu","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Moduł sprężystości przy rozciąganiu","reference":"ISO 10406-1 Edition 2 2015 pkt.6","norm_bases":["ISO 10406-1 Edition 2 2015 pkt.6"],"lab_section":"Laboratorium Badawcze Materiałów i Konstrukcji Budowlanych; Al. Politechniki 6, 93-590 Łódź","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pręty kompozytowe do zbrojenia betonu Moduł sprężystości przy rozciąganiu ISO 10406-1 Edition 2 2015 pkt.6 Prety kompozytowe do zbrojenia betonu Modul sprezystosci przy rozciaganiu ISO 10406-1 Edition 2 2015 pkt.6","categories":["construction","materials"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Building Materials and Structures Testing Laboratory; Al. Politechniki 6, 93-590 Łódź","methodology_en":"Modulus of elasticity in tension","search_en":"Composite bars for concrete reinforcement Modulus of elasticity in tension Building Materials and Structures Testing Laboratory; Al. Politechniki 6, 93-590 Łódź ISO 10406-1 Edition 2 2015 pkt.6","test_object_en":"Composite bars for concrete reinforcement","lab_section_zh":"建筑材料与结构检测实验室；Al. Politechniki 6, 93-590 Łódź","search_zh":"建筑材料与结构检测实验室；Al. Politechniki 6, 93-590 Łódź ISO 10406-1 Edition 2 2015 pkt.6"}],"has_pdf":true}