{"lab":{"_id":"69ad52a3de79e566650fb2b6","accr_number":"AB 535","country":"PL","accr_body":"PCA","address":"INSTYTUT BADAŃ I CERTYFIKACJI Sp. z o. o., ul. Przemysłowa 23, 35-105 Rzeszów","categories":["construction"],"city":"Rzeszów","imported_at":"2026-03-08T10:42:43.265Z","methods_count":68,"name":"CENTRUM TECHNOLOGICZNE BUDOWNICTWA","parse_status":"parsed","parse_version":3,"pdf_files":["AB_535.pdf"],"scope_summary":"","search_text":"centrum technologiczne budownictwa instytut badań i certyfikacji sp. z o. o., ul. przemysłowa 23, 35-105 rzeszów construction water other electronics environment","status":"active","updated_at":"2026-03-08T14:51:24.554Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:24.554Z","location":{"type":"Point","coordinates":[21.9991,50.0412]},"email_confidence":"high","email_mx":true,"email_source":"https://ctb-ibc.pl/kontakt/","fields_of_testing":[{"codes":"C/5","pl":"Badania chemiczne wyrobów, materiałów i obiektów budowlanych","en":"Chemical tests of building products, building materials and building items"},{"codes":"J/5","pl":"Badania mechaniczne wyrobów, materiałów i obiektów budowlanych","en":"Mechanical tests of building products, building materials and building items"},{"codes":"N/5","pl":"Badania właściwości fizycznych wyrobów, materiałów i obiektów budowlanych","en":"Tests of physical properties of building products, building materials and building items"},{"codes":"J/5/P","pl":"Badania mechaniczne i pobieranie próbek wyrobów, materiałów i obiektów budowlanych","en":"Mechanical tests and sampling of building products, building materials and building items"},{"codes":"N/5/P","pl":"Badania właściwości fizycznych i pobieranie próbek wyrobów, materiałów i obiektów budowlanych","en":"Tests of physical properties and sampling of building products, building materials and building items"},{"codes":"P/5","pl":"Pobieranie próbek, laboratoria akredytowane do pobierania próbek wyrobów, materiałów oraz obiektów budowlanych","en":"Sampling, laboratories accredited for sampling of building products, materials and items"}],"issue":{"no":"26","date":"20.08.2025"},"parse_date":"2026-07-20T07:09:42.037Z","parse_source":"script-pdfplumber","map_coord":[50.016621,21.962985],"map_geo":"nominatim-street","has_en":true,"category_counts":{"construction":49,"other":19,"water":3},"category_scores":{"construction":33.82,"other":5.08,"water":0.13},"has_zh":true},"methods":[{"_id":"6a5dc9b6f1c10c8ce825cbc6","lab_id":"69ad52a3de79e566650fb2b6","country":"PL","accr_number":"AB 535","accr_body":"PCA","test_object":"Beton","test_object_en":"Concrete","methodology":"Przepuszczalność wody przez beton","methodology_en":"Water permeability of concrete","parameters":[{"name":"Zakres","range":"(0,2 – 1,6) MPa"}],"parameters_en":[{"name":"Range","range":"(0,2 – 1,6) MPa"}],"technique":"Metoda ciśnieniowa","techniques":["Metoda ciśnieniowa"],"technique_en":"Pressure method","computed":[],"computed_en":[],"activity":"Przepuszczalność wody przez beton\nZakres (0,2 – 1,6) MPa\nMetoda ciśnieniowa","reference":"PN-88/B-06250","norm_bases":["PN-88/B-06250"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Beton Przepuszczalność wody przez beton\nZakres (0,2 – 1,6) MPa\nMetoda ciśnieniowa PN-88/B-06250 Beton Przepuszczalnosc wody przez beton\nZakres (0,2 – 1,6) MPa\nMetoda cisnieniowa PN-88/B-06250","categories":["water","construction"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Concrete Water permeability of concrete Pressure method Range PN-88/B-06250","parameters_zh":[{"name":"范围","range":"(0,2 – 1,6) MPa"}],"search_zh":"混凝土 混凝土透水性 压力法 范围 PN-88/B-06250","test_object_zh":"混凝土","technique_zh":"压力法","methodology_zh":"混凝土透水性"},{"_id":"6a5dc9b6f1c10c8ce825cbc7","lab_id":"69ad52a3de79e566650fb2b6","country":"PL","accr_number":"AB 535","accr_body":"PCA","test_object":"Beton","test_object_en":"Concrete","methodology":"Odporność na działanie mrozu","methodology_en":"Resistance to freezing","parameters":[],"parameters_en":[],"technique":"Metoda zwykła","techniques":["Metoda zwykła"],"technique_en":"Ordinary method","computed":[],"computed_en":[],"activity":"Odporność na działanie mrozu\nMetoda zwykła","reference":"PN-88/B-06250 | PN-B-06265:2018-10 Załącznik N | PN-B-06265:2022-08 Załącznik N","norm_bases":["PN-88/B-06250","PN-B-06265:2018-10 Załącznik N","PN-B-06265:2022-08 Załącznik N"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Beton Odporność na działanie mrozu\nMetoda zwykła PN-88/B-06250 | PN-B-06265:2018-10 Załącznik N | PN-B-06265:2022-08 Załącznik N Beton Odpornosc na dzialanie mrozu\nMetoda zwykla PN-88/B-06250 | PN-B-06265:2018-10 Zalacznik N | PN-B-06265:2022-08 Zalacznik N","categories":["construction"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Concrete Resistance to freezing Ordinary method PN-88/B-06250 | PN-B-06265:2018-10 Załącznik N | PN-B-06265:2022-08 Załącznik N","methodology_zh":"抗冻性","search_zh":"混凝土 抗冻性 常规法 PN-88/B-06250 | PN-B-06265:2018-10 Załącznik N | PN-B-06265:2022-08 Załącznik N","test_object_zh":"混凝土","technique_zh":"常规法"},{"_id":"6a5dc9b6f1c10c8ce825cbc8","lab_id":"69ad52a3de79e566650fb2b6","country":"PL","accr_number":"AB 535","accr_body":"PCA","test_object":"Beton","test_object_en":"Concrete","methodology":"Wytrzymałość na ściskanie","methodology_en":"Compressive strength","parameters":[{"name":"Zakres","range":"(1 – 3000) kN"}],"parameters_en":[{"name":"Range","range":"(1 – 3000) kN"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ściskanie\nZakres (1 – 3000) kN","reference":"PN-88/B-06250 | PN-EN 12390-3:2011+AC:2012 | PN-EN 12390-3:2019-07 | PN-EN 12504-1:2011 | PN-EN 12504-1:2019-08 | PN-EN 12504-1:2019-08/AC:2021-01","norm_bases":["PN-88/B-06250","PN-EN 12390-3:2011+AC:2012","PN-EN 12390-3:2019-07","PN-EN 12504-1:2011","PN-EN 12504-1:2019-08","PN-EN 12504-1:2019-08/AC:2021-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Beton Wytrzymałość na ściskanie\nZakres (1 – 3000) kN PN-88/B-06250 | PN-EN 12390-3:2011+AC:2012 | PN-EN 12390-3:2019-07 | PN-EN 12504-1:2011 | PN-EN 12504-1:2019-08 | PN-EN 12504-1:2019-08/AC:2021-01 Beton Wytrzymalosc na sciskanie\nZakres (1 – 3000) kN PN-88/B-06250 | PN-EN 12390-3:2011+AC:2012 | PN-EN 12390-3:2019-07 | PN-EN 12504-1:2011 | PN-EN 12504-1:2019-08 | PN-EN 12504-1:2019-08/AC:2021-01","categories":["construction"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Concrete Compressive strength Range PN-88/B-06250 | PN-EN 12390-3:2011+AC:2012 | PN-EN 12390-3:2019-07 | PN-EN 12504-1:2011 | PN-EN 12504-1:2019-08 | PN-EN 12504-1:2019-08/AC:2021-01","methodology_zh":"抗压强度","parameters_zh":[{"name":"范围","range":"(1 – 3000) kN"}],"search_zh":"混凝土 抗压强度 范围 PN-88/B-06250 | PN-EN 12390-3:2011+AC:2012 | PN-EN 12390-3:2019-07 | PN-EN 12504-1:2011 | PN-EN 12504-1:2019-08 | PN-EN 12504-1:2019-08/AC:2021-01","test_object_zh":"混凝土"},{"_id":"6a5dc9b6f1c10c8ce825cbc9","lab_id":"69ad52a3de79e566650fb2b6","country":"PL","accr_number":"AB 535","accr_body":"PCA","test_object":"Beton","test_object_en":"Concrete","methodology":"Nasiąkliwość","methodology_en":"Water absorption","parameters":[],"parameters_en":[],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Nasiąkliwość\nMetoda wagowa","reference":"PN-88/B-06250","norm_bases":["PN-88/B-06250"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Beton Nasiąkliwość\nMetoda wagowa PN-88/B-06250 Beton Nasiakliwosc\nMetoda wagowa PN-88/B-06250","categories":["construction"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Concrete Water absorption Gravimetric method PN-88/B-06250","methodology_zh":"吸水率","search_zh":"混凝土 吸水率 重量法 PN-88/B-06250","technique_zh":"重量法","test_object_zh":"混凝土"},{"_id":"6a5dc9b6f1c10c8ce825cbca","lab_id":"69ad52a3de79e566650fb2b6","country":"PL","accr_number":"AB 535","accr_body":"PCA","test_object":"Beton","test_object_en":"Concrete","methodology":"Wytrzymałość na rozciąganie przy rozłupywaniu","methodology_en":"Splitting tensile strength","parameters":[{"name":"Zakres","range":"(1 – 3000) kN"}],"parameters_en":[{"name":"Range","range":"(1 – 3000) kN"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na rozciąganie przy rozłupywaniu\nZakres (1 – 3000) kN","reference":"PN-EN 12390-6:2011 | PN-EN 12390-6:2024-04","norm_bases":["PN-EN 12390-6:2011","PN-EN 12390-6:2024-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Beton Wytrzymałość na rozciąganie przy rozłupywaniu\nZakres (1 – 3000) kN PN-EN 12390-6:2011 | PN-EN 12390-6:2024-04 Beton Wytrzymalosc na rozciaganie przy rozlupywaniu\nZakres (1 – 3000) kN PN-EN 12390-6:2011 | PN-EN 12390-6:2024-04","categories":["construction"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Concrete Splitting tensile strength Range PN-EN 12390-6:2011 | PN-EN 12390-6:2024-04","methodology_zh":"劈裂抗拉强度","parameters_zh":[{"name":"范围","range":"(1 – 3000) kN"}],"search_zh":"混凝土 劈裂抗拉强度 范围 PN-EN 12390-6:2011 | PN-EN 12390-6:2024-04","test_object_zh":"混凝土"},{"_id":"6a5dc9b6f1c10c8ce825cbcb","lab_id":"69ad52a3de79e566650fb2b6","country":"PL","accr_number":"AB 535","accr_body":"PCA","test_object":"Beton","test_object_en":"Concrete","methodology":"Gęstość","methodology_en":"Density","parameters":[{"name":"Określenie objętości na podstawie wymiarów próbki"}],"parameters_en":[{"name":"Determination of volume from the sample dimensions"}],"technique":"Metoda wagowo-objętościowa","techniques":["Metoda wagowo-objętościowa"],"technique_en":"Gravimetric-volumetric method","computed":[],"computed_en":[],"activity":"Gęstość\nOkreślenie objętości na podstawie wymiarów próbki\nMetoda wagowo-objętościowa","reference":"PN-EN 12390-7:2011 | PN-EN 12390-7:2019-08 | PN-EN 12390-7:2019-08/AC:2021-01","norm_bases":["PN-EN 12390-7:2011","PN-EN 12390-7:2019-08","PN-EN 12390-7:2019-08/AC:2021-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Beton Gęstość\nOkreślenie objętości na podstawie wymiarów próbki\nMetoda wagowo-objętościowa PN-EN 12390-7:2011 | PN-EN 12390-7:2019-08 | PN-EN 12390-7:2019-08/AC:2021-01 Beton Gestosc\nOkreslenie objetosci na podstawie wymiarow probki\nMetoda wagowo-objetosciowa PN-EN 12390-7:2011 | PN-EN 12390-7:2019-08 | PN-EN 12390-7:2019-08/AC:2021-01","categories":["construction"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Concrete Density Gravimetric-volumetric method Determination of volume from the sample dimensions PN-EN 12390-7:2011 | PN-EN 12390-7:2019-08 | PN-EN 12390-7:2019-08/AC:2021-01","methodology_zh":"密度","search_zh":"混凝土 密度 重量-容量法 PN-EN 12390-7:2011 | PN-EN 12390-7:2019-08 | PN-EN 12390-7:2019-08/AC:2021-01","technique_zh":"重量-容量法","test_object_zh":"混凝土"},{"_id":"6a5dc9b6f1c10c8ce825cbcc","lab_id":"69ad52a3de79e566650fb2b6","country":"PL","accr_number":"AB 535","accr_body":"PCA","test_object":"Beton","test_object_en":"Concrete","methodology":"Głębokość penetracji wody pod ciśnieniem","methodology_en":"Depth of penetration of water under pressure","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Głębokość penetracji wody pod ciśnieniem","reference":"PN-EN 12390-8:2011 | PN-EN 12390-8:2019-08","norm_bases":["PN-EN 12390-8:2011","PN-EN 12390-8:2019-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Beton Głębokość penetracji wody pod ciśnieniem PN-EN 12390-8:2011 | PN-EN 12390-8:2019-08 Beton Glebokosc penetracji wody pod cisnieniem PN-EN 12390-8:2011 | PN-EN 12390-8:2019-08","categories":["water","construction"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Concrete Depth of penetration of water under pressure PN-EN 12390-8:2011 | PN-EN 12390-8:2019-08","methodology_zh":"压力水渗透深度","search_zh":"混凝土 压力水渗透深度 PN-EN 12390-8:2011 | PN-EN 12390-8:2019-08","test_object_zh":"混凝土"},{"_id":"6a5dc9b6f1c10c8ce825cbcd","lab_id":"69ad52a3de79e566650fb2b6","country":"PL","accr_number":"AB 535","accr_body":"PCA","test_object":"Beton","test_object_en":"Concrete","methodology":"Odporność na zamrażanie i odmrażanie","methodology_en":"Freeze-thaw resistance","parameters":[],"parameters_en":[],"technique":"Metoda referencyjna (slab test)","techniques":["Metoda referencyjna (slab test)"],"technique_en":"Reference method (slab test)","computed":[],"computed_en":[],"activity":"Odporność na zamrażanie i odmrażanie\nMetoda referencyjna (slab test)","reference":"PKN-CEN/TS 12390-9:2007 PKN-CEN/TS 12390-9:2017-07 | PN-B-06265:2018-10 Załącznik O | PN-B-06265:2022-08 Załącznik O","norm_bases":["PKN-CEN/TS 12390-9:2007 PKN-CEN/TS 12390-9:2017-07","PN-B-06265:2018-10 Załącznik O","PN-B-06265:2022-08 Załącznik O"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Beton Odporność na zamrażanie i odmrażanie\nMetoda referencyjna (slab test) PKN-CEN/TS 12390-9:2007 PKN-CEN/TS 12390-9:2017-07 | PN-B-06265:2018-10 Załącznik O | PN-B-06265:2022-08 Załącznik O Beton Odpornosc na zamrazanie i odmrazanie\nMetoda referencyjna (slab test) PKN-CEN/TS 12390-9:2007 PKN-CEN/TS 12390-9:2017-07 | PN-B-06265:2018-10 Zalacznik O | PN-B-06265:2022-08 Zalacznik O","categories":["construction"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Concrete Freeze-thaw resistance Reference method (slab test) PKN-CEN/TS 12390-9:2007 PKN-CEN/TS 12390-9:2017-07 | PN-B-06265:2018-10 Załącznik O | PN-B-06265:2022-08 Załącznik O","search_zh":"混凝土 PKN-CEN/TS 12390-9:2007 PKN-CEN/TS 12390-9:2017-07 | PN-B-06265:2018-10 Załącznik O | PN-B-06265:2022-08 Załącznik O","test_object_zh":"混凝土"},{"_id":"6a5dc9b6f1c10c8ce825cbce","lab_id":"69ad52a3de79e566650fb2b6","country":"PL","accr_number":"AB 535","accr_body":"PCA","test_object":"Beton","test_object_en":"Concrete","methodology":"Pobieranie próbek","methodology_en":"Sampling","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek","reference":"PN-EN 12504-1:2011 | PN-EN 12504-1:2019-08 | PN-EN 12504-1:2019-08/AC:2021-01","norm_bases":["PN-EN 12504-1:2011","PN-EN 12504-1:2019-08","PN-EN 12504-1:2019-08/AC:2021-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Beton Pobieranie próbek PN-EN 12504-1:2011 | PN-EN 12504-1:2019-08 | PN-EN 12504-1:2019-08/AC:2021-01 Beton Pobieranie probek PN-EN 12504-1:2011 | PN-EN 12504-1:2019-08 | PN-EN 12504-1:2019-08/AC:2021-01","categories":["construction"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Concrete Sampling PN-EN 12504-1:2011 | PN-EN 12504-1:2019-08 | PN-EN 12504-1:2019-08/AC:2021-01","methodology_zh":"样品采集","search_zh":"混凝土 样品采集 PN-EN 12504-1:2011 | PN-EN 12504-1:2019-08 | PN-EN 12504-1:2019-08/AC:2021-01","test_object_zh":"混凝土"},{"_id":"6a5dc9b6f1c10c8ce825cbcf","lab_id":"69ad52a3de79e566650fb2b6","country":"PL","accr_number":"AB 535","accr_body":"PCA","test_object":"Beton","test_object_en":"Concrete","methodology":"Wytrzymałość na zginanie","methodology_en":"Flexural strength","parameters":[{"name":"Zakres","range":"(1 – 200) kN"}],"parameters_en":[{"name":"Range","range":"(1 – 200) kN"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na zginanie\nZakres (1 – 200) kN","reference":"PN-EN 12390-5:2019-08 NO-17-A204:2015","norm_bases":["PN-EN 12390-5:2019-08 NO-17-A204:2015"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Beton Wytrzymałość na zginanie\nZakres (1 – 200) kN PN-EN 12390-5:2019-08 NO-17-A204:2015 Beton Wytrzymalosc na zginanie\nZakres (1 – 200) kN PN-EN 12390-5:2019-08 NO-17-A204:2015","categories":["construction"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Concrete Flexural strength Range PN-EN 12390-5:2019-08 NO-17-A204:2015","parameters_zh":[{"name":"范围","range":"(1 – 200) kN"}],"search_zh":"混凝土 抗弯强度 范围 PN-EN 12390-5:2019-08 NO-17-A204:2015","test_object_zh":"混凝土","methodology_zh":"抗弯强度"},{"_id":"6a5dc9b6f1c10c8ce825cbd0","lab_id":"69ad52a3de79e566650fb2b6","country":"PL","accr_number":"AB 535","accr_body":"PCA","test_object":"Mieszanka betonowa","test_object_en":"Fresh concrete","methodology":"Konsystencja","methodology_en":"Consistency","parameters":[],"parameters_en":[],"technique":"Metoda stożka opadowego","techniques":["Metoda stożka opadowego"],"technique_en":"Fall cone method","computed":[],"computed_en":[],"activity":"Konsystencja\nMetoda stożka opadowego","reference":"PN-88/B-06250 | PN-EN 12350-2:2011 | PN-EN 12350-2:2019-07","norm_bases":["PN-88/B-06250","PN-EN 12350-2:2011","PN-EN 12350-2:2019-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mieszanka betonowa Konsystencja\nMetoda stożka opadowego PN-88/B-06250 | PN-EN 12350-2:2011 | PN-EN 12350-2:2019-07 Mieszanka betonowa Konsystencja\nMetoda stozka opadowego PN-88/B-06250 | PN-EN 12350-2:2011 | PN-EN 12350-2:2019-07","categories":["construction"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Fresh concrete Consistency Fall cone method PN-88/B-06250 | PN-EN 12350-2:2011 | PN-EN 12350-2:2019-07","methodology_zh":"稠度","search_zh":"混凝土拌合物 稠度 PN-88/B-06250 | PN-EN 12350-2:2011 | PN-EN 12350-2:2019-07","test_object_zh":"混凝土拌合物"},{"_id":"6a5dc9b6f1c10c8ce825cbd1","lab_id":"69ad52a3de79e566650fb2b6","country":"PL","accr_number":"AB 535","accr_body":"PCA","test_object":"Mieszanka betonowa","test_object_en":"Fresh concrete","methodology":"Zawartość powietrza","methodology_en":"Air content","parameters":[],"parameters_en":[],"technique":"Metoda ciśnieniomierza","techniques":["Metoda ciśnieniomierza"],"technique_en":"Pressure gauge method","computed":[],"computed_en":[],"activity":"Zawartość powietrza\nMetoda ciśnieniomierza","reference":"PN-EN 12350-7:2011 | PN-EN 12350-7:2019-08","norm_bases":["PN-EN 12350-7:2011","PN-EN 12350-7:2019-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mieszanka betonowa Zawartość powietrza\nMetoda ciśnieniomierza PN-EN 12350-7:2011 | PN-EN 12350-7:2019-08 Mieszanka betonowa Zawartosc powietrza\nMetoda cisnieniomierza PN-EN 12350-7:2011 | PN-EN 12350-7:2019-08","categories":["construction"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Fresh concrete Air content Pressure gauge method PN-EN 12350-7:2011 | PN-EN 12350-7:2019-08","methodology_zh":"含气量","search_zh":"混凝土拌合物 含气量 压力计法 PN-EN 12350-7:2011 | PN-EN 12350-7:2019-08","technique_zh":"压力计法","test_object_zh":"混凝土拌合物"},{"_id":"6a5dc9b6f1c10c8ce825cbd2","lab_id":"69ad52a3de79e566650fb2b6","country":"PL","accr_number":"AB 535","accr_body":"PCA","test_object":"Mieszanka betonowa","test_object_en":"Fresh concrete","methodology":"Konsystencja","methodology_en":"Consistency","parameters":[{"name":"Zakres","range":"(20 – 70) cm"}],"parameters_en":[{"name":"Range","range":"(20 – 70) cm"}],"technique":"Metoda stolika rozpływowego","techniques":["Metoda stolika rozpływowego"],"technique_en":"Flow table method","computed":[],"computed_en":[],"activity":"Konsystencja\nZakres (20 – 70) cm\nMetoda stolika rozpływowego","reference":"PN-EN 12350-5:2011 | PN-EN 12350-5:2019-08","norm_bases":["PN-EN 12350-5:2011","PN-EN 12350-5:2019-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mieszanka betonowa Konsystencja\nZakres (20 – 70) cm\nMetoda stolika rozpływowego PN-EN 12350-5:2011 | PN-EN 12350-5:2019-08 Mieszanka betonowa Konsystencja\nZakres (20 – 70) cm\nMetoda stolika rozplywowego PN-EN 12350-5:2011 | PN-EN 12350-5:2019-08","categories":["construction"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Fresh concrete Consistency Flow table method Range PN-EN 12350-5:2011 | PN-EN 12350-5:2019-08","methodology_zh":"稠度","parameters_zh":[{"name":"范围","range":"(20 – 70) cm"}],"search_zh":"混凝土拌合物 稠度 跳桌法 范围 PN-EN 12350-5:2011 | PN-EN 12350-5:2019-08","test_object_zh":"混凝土拌合物","technique_zh":"跳桌法"},{"_id":"6a5dc9b6f1c10c8ce825cbd3","lab_id":"69ad52a3de79e566650fb2b6","country":"PL","accr_number":"AB 535","accr_body":"PCA","test_object":"Mieszanka betonowa","test_object_en":"Fresh concrete","methodology":"Konsystencja","methodology_en":"Consistency","parameters":[],"parameters_en":[],"technique":"Metoda rozpływu","techniques":["Metoda rozpływu"],"technique_en":"Spread method","computed":[],"computed_en":[],"activity":"Konsystencja\nMetoda rozpływu","reference":"PN-EN 12350-8:2012 | PN-EN 12350-8:2019-08","norm_bases":["PN-EN 12350-8:2012","PN-EN 12350-8:2019-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mieszanka betonowa Konsystencja\nMetoda rozpływu PN-EN 12350-8:2012 | PN-EN 12350-8:2019-08 Mieszanka betonowa Konsystencja\nMetoda rozplywu PN-EN 12350-8:2012 | PN-EN 12350-8:2019-08","categories":["construction"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Fresh concrete Consistency Spread method PN-EN 12350-8:2012 | PN-EN 12350-8:2019-08","methodology_zh":"稠度","search_zh":"混凝土拌合物 稠度 PN-EN 12350-8:2012 | PN-EN 12350-8:2019-08","test_object_zh":"混凝土拌合物"},{"_id":"6a5dc9b6f1c10c8ce825cbd4","lab_id":"69ad52a3de79e566650fb2b6","country":"PL","accr_number":"AB 535","accr_body":"PCA","test_object":"Mieszanka betonowa","test_object_en":"Fresh concrete","methodology":"Gęstość","methodology_en":"Density","parameters":[],"parameters_en":[],"technique":"Metoda wagowo-objętościowa","techniques":["Metoda wagowo-objętościowa"],"technique_en":"Gravimetric-volumetric method","computed":[],"computed_en":[],"activity":"Gęstość\nMetoda wagowo-objętościowa","reference":"PN-EN 12350-6:2011 | PN-EN 12350-6:2019-08","norm_bases":["PN-EN 12350-6:2011","PN-EN 12350-6:2019-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mieszanka betonowa Gęstość\nMetoda wagowo-objętościowa PN-EN 12350-6:2011 | PN-EN 12350-6:2019-08 Mieszanka betonowa Gestosc\nMetoda wagowo-objetosciowa PN-EN 12350-6:2011 | PN-EN 12350-6:2019-08","categories":["construction"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Fresh concrete Density Gravimetric-volumetric method PN-EN 12350-6:2011 | PN-EN 12350-6:2019-08","methodology_zh":"密度","search_zh":"混凝土拌合物 密度 重量-容量法 PN-EN 12350-6:2011 | PN-EN 12350-6:2019-08","technique_zh":"重量-容量法","test_object_zh":"混凝土拌合物"},{"_id":"6a5dc9b6f1c10c8ce825cbd5","lab_id":"69ad52a3de79e566650fb2b6","country":"PL","accr_number":"AB 535","accr_body":"PCA","test_object":"Mieszanka betonowa","test_object_en":"Fresh concrete","methodology":"Pobieranie próbek","methodology_en":"Sampling","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek","reference":"PN-EN 12350-1:2011 | PN-EN 12350-1:2019-07 | PN-EN 12350-1:2019-07/Ap1:2022-06","norm_bases":["PN-EN 12350-1:2011","PN-EN 12350-1:2019-07","PN-EN 12350-1:2019-07/Ap1:2022-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mieszanka betonowa Pobieranie próbek PN-EN 12350-1:2011 | PN-EN 12350-1:2019-07 | PN-EN 12350-1:2019-07/Ap1:2022-06 Mieszanka betonowa Pobieranie probek PN-EN 12350-1:2011 | PN-EN 12350-1:2019-07 | PN-EN 12350-1:2019-07/Ap1:2022-06","categories":["construction"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Fresh concrete Sampling PN-EN 12350-1:2011 | PN-EN 12350-1:2019-07 | PN-EN 12350-1:2019-07/Ap1:2022-06","methodology_zh":"样品采集","search_zh":"混凝土拌合物 样品采集 PN-EN 12350-1:2011 | PN-EN 12350-1:2019-07 | PN-EN 12350-1:2019-07/Ap1:2022-06","test_object_zh":"混凝土拌合物"},{"_id":"6a5dc9b6f1c10c8ce825cbd6","lab_id":"69ad52a3de79e566650fb2b6","country":"PL","accr_number":"AB 535","accr_body":"PCA","test_object":"Cementy","test_object_en":"Cements","methodology":"Wytrzymałość na zginanie","methodology_en":"Flexural strength","parameters":[{"name":"Zakres","range":"(1 – 100) kN"}],"parameters_en":[{"name":"Range","range":"(1 – 100) kN"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na zginanie\nZakres (1 – 100) kN","reference":"PN-EN 196-1:2016-07","norm_bases":["PN-EN 196-1:2016-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Cementy Wytrzymałość na zginanie\nZakres (1 – 100) kN PN-EN 196-1:2016-07 Cementy Wytrzymalosc na zginanie\nZakres (1 – 100) kN PN-EN 196-1:2016-07","categories":["construction"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cements Flexural strength Range PN-EN 196-1:2016-07","parameters_zh":[{"name":"范围","range":"(1 – 100) kN"}],"search_zh":"水泥 抗弯强度 范围 PN-EN 196-1:2016-07","methodology_zh":"抗弯强度","test_object_zh":"水泥"},{"_id":"6a5dc9b6f1c10c8ce825cbd7","lab_id":"69ad52a3de79e566650fb2b6","country":"PL","accr_number":"AB 535","accr_body":"PCA","test_object":"Cementy","test_object_en":"Cements","methodology":"Wytrzymałość na ściskanie","methodology_en":"Compressive strength","parameters":[{"name":"Zakres","range":"(1 – 3000) kN"}],"parameters_en":[{"name":"Range","range":"(1 – 3000) kN"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ściskanie\nZakres (1 – 3000) kN","reference":"PN-EN 196-1:2016-07","norm_bases":["PN-EN 196-1:2016-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Cementy Wytrzymałość na ściskanie\nZakres (1 – 3000) kN PN-EN 196-1:2016-07 Cementy Wytrzymalosc na sciskanie\nZakres (1 – 3000) kN PN-EN 196-1:2016-07","categories":["construction"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cements Compressive strength Range PN-EN 196-1:2016-07","methodology_zh":"抗压强度","parameters_zh":[{"name":"范围","range":"(1 – 3000) kN"}],"search_zh":"水泥 抗压强度 范围 PN-EN 196-1:2016-07","test_object_zh":"水泥"},{"_id":"6a5dc9b6f1c10c8ce825cbd8","lab_id":"69ad52a3de79e566650fb2b6","country":"PL","accr_number":"AB 535","accr_body":"PCA","test_object":"Zaprawy","test_object_en":"Mortars","methodology":"Konsystencja","methodology_en":"Consistency","parameters":[{"name":"Zakres","range":"(100 – 300) mm"}],"parameters_en":[{"name":"Range","range":"(100 – 300) mm"}],"technique":"Metoda stolika rozpływowego","techniques":["Metoda stolika rozpływowego"],"technique_en":"Flow table method","computed":[],"computed_en":[],"activity":"Konsystencja\nZakres (100 – 300) mm\nMetoda stolika rozpływowego","reference":"PN-EN 1015-3:2000+A1:2005+ A2:2007","norm_bases":["PN-EN 1015-3:2000+A1:2005+ A2:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zaprawy Konsystencja\nZakres (100 – 300) mm\nMetoda stolika rozpływowego PN-EN 1015-3:2000+A1:2005+ A2:2007 Zaprawy Konsystencja\nZakres (100 – 300) mm\nMetoda stolika rozplywowego PN-EN 1015-3:2000+A1:2005+ A2:2007","categories":["other"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Mortars Consistency Flow table method Range PN-EN 1015-3:2000+A1:2005+ A2:2007","methodology_zh":"稠度","parameters_zh":[{"name":"范围","range":"(100 – 300) mm"}],"search_zh":"砂浆 稠度 跳桌法 范围 PN-EN 1015-3:2000+A1:2005+ A2:2007","test_object_zh":"砂浆","technique_zh":"跳桌法"},{"_id":"6a5dc9b6f1c10c8ce825cbd9","lab_id":"69ad52a3de79e566650fb2b6","country":"PL","accr_number":"AB 535","accr_body":"PCA","test_object":"Zaprawy","test_object_en":"Mortars","methodology":"Gęstość objętościowa świeżej zaprawy","methodology_en":"Bulk density of fresh mortar","parameters":[],"parameters_en":[],"technique":"Metoda wagowo-objętościowa","techniques":["Metoda wagowo-objętościowa"],"technique_en":"Gravimetric-volumetric method","computed":[],"computed_en":[],"activity":"Gęstość objętościowa świeżej zaprawy\nMetoda wagowo-objętościowa","reference":"PN-EN 1015-6:2000+A1:2007","norm_bases":["PN-EN 1015-6:2000+A1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zaprawy Gęstość objętościowa świeżej zaprawy\nMetoda wagowo-objętościowa PN-EN 1015-6:2000+A1:2007 Zaprawy Gestosc objetosciowa swiezej zaprawy\nMetoda wagowo-objetosciowa PN-EN 1015-6:2000+A1:2007","categories":["other"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Mortars Bulk density of fresh mortar Gravimetric-volumetric method PN-EN 1015-6:2000+A1:2007","search_zh":"砂浆 新拌砂浆表观密度 重量-容量法 PN-EN 1015-6:2000+A1:2007","technique_zh":"重量-容量法","test_object_zh":"砂浆","methodology_zh":"新拌砂浆表观密度"},{"_id":"6a5dc9b6f1c10c8ce825cbda","lab_id":"69ad52a3de79e566650fb2b6","country":"PL","accr_number":"AB 535","accr_body":"PCA","test_object":"Zaprawy","test_object_en":"Mortars","methodology":"Zawartość powietrza w świeżej zaprawie","methodology_en":"Air content in fresh mortar","parameters":[],"parameters_en":[],"technique":"Metoda ciśnieniowa","techniques":["Metoda ciśnieniowa"],"technique_en":"Pressure method","computed":[],"computed_en":[],"activity":"Zawartość powietrza w świeżej zaprawie\nMetoda ciśnieniowa","reference":"PN-EN 1015-7:2000","norm_bases":["PN-EN 1015-7:2000"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zaprawy Zawartość powietrza w świeżej zaprawie\nMetoda ciśnieniowa PN-EN 1015-7:2000 Zaprawy Zawartosc powietrza w swiezej zaprawie\nMetoda cisnieniowa PN-EN 1015-7:2000","categories":["other"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Mortars Air content in fresh mortar Pressure method PN-EN 1015-7:2000","search_zh":"砂浆 新拌砂浆含气量 压力法 PN-EN 1015-7:2000","technique_zh":"压力法","test_object_zh":"砂浆","methodology_zh":"新拌砂浆含气量"},{"_id":"6a5dc9b6f1c10c8ce825cbdb","lab_id":"69ad52a3de79e566650fb2b6","country":"PL","accr_number":"AB 535","accr_body":"PCA","test_object":"Zaprawy","test_object_en":"Mortars","methodology":"Wytrzymałość na ściskanie","methodology_en":"Compressive strength","parameters":[{"name":"Zakres","range":"(1 – 3000) kN"}],"parameters_en":[{"name":"Range","range":"(1 – 3000) kN"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ściskanie\nZakres (1 – 3000) kN","reference":"PN-EN 1015-11:2001+A1:2007 | PN-EN 1015-11:2020-04","norm_bases":["PN-EN 1015-11:2001+A1:2007","PN-EN 1015-11:2020-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zaprawy Wytrzymałość na ściskanie\nZakres (1 – 3000) kN PN-EN 1015-11:2001+A1:2007 | PN-EN 1015-11:2020-04 Zaprawy Wytrzymalosc na sciskanie\nZakres (1 – 3000) kN PN-EN 1015-11:2001+A1:2007 | PN-EN 1015-11:2020-04","categories":["other"],"row_index":21,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Mortars Compressive strength Range PN-EN 1015-11:2001+A1:2007 | PN-EN 1015-11:2020-04","methodology_zh":"抗压强度","parameters_zh":[{"name":"范围","range":"(1 – 3000) kN"}],"search_zh":"砂浆 抗压强度 范围 PN-EN 1015-11:2001+A1:2007 | PN-EN 1015-11:2020-04","test_object_zh":"砂浆"},{"_id":"6a5dc9b6f1c10c8ce825cbdc","lab_id":"69ad52a3de79e566650fb2b6","country":"PL","accr_number":"AB 535","accr_body":"PCA","test_object":"Zaprawy","test_object_en":"Mortars","methodology":"Wytrzymałość na zginanie","methodology_en":"Flexural strength","parameters":[{"name":"Zakres","range":"(1 – 100) kN"}],"parameters_en":[{"name":"Range","range":"(1 – 100) kN"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na zginanie\nZakres (1 – 100) kN","reference":"PN-EN 1015-11:2001+A1:2007 | PN-EN 1015-11:2020-04","norm_bases":["PN-EN 1015-11:2001+A1:2007","PN-EN 1015-11:2020-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zaprawy Wytrzymałość na zginanie\nZakres (1 – 100) kN PN-EN 1015-11:2001+A1:2007 | PN-EN 1015-11:2020-04 Zaprawy Wytrzymalosc na zginanie\nZakres (1 – 100) kN PN-EN 1015-11:2001+A1:2007 | PN-EN 1015-11:2020-04","categories":["other"],"row_index":22,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Mortars Flexural strength Range PN-EN 1015-11:2001+A1:2007 | PN-EN 1015-11:2020-04","parameters_zh":[{"name":"范围","range":"(1 – 100) kN"}],"search_zh":"砂浆 抗弯强度 范围 PN-EN 1015-11:2001+A1:2007 | PN-EN 1015-11:2020-04","methodology_zh":"抗弯强度","test_object_zh":"砂浆"},{"_id":"6a5dc9b6f1c10c8ce825cbdd","lab_id":"69ad52a3de79e566650fb2b6","country":"PL","accr_number":"AB 535","accr_body":"PCA","test_object":"Podkłady podłogowe","test_object_en":"Floor screeds","methodology":"Wytrzymałość na ściskanie","methodology_en":"Compressive strength","parameters":[{"name":"Zakres","range":"(1 – 3000) kN"}],"parameters_en":[{"name":"Range","range":"(1 – 3000) kN"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ściskanie\nZakres (1 – 3000) kN","reference":"PN-EN 13892-2:2004","norm_bases":["PN-EN 13892-2:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Podkłady podłogowe Wytrzymałość na ściskanie\nZakres (1 – 3000) kN PN-EN 13892-2:2004 Podklady podlogowe Wytrzymalosc na sciskanie\nZakres (1 – 3000) kN PN-EN 13892-2:2004","categories":["other"],"row_index":23,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Floor screeds Compressive strength Range PN-EN 13892-2:2004","methodology_zh":"抗压强度","parameters_zh":[{"name":"范围","range":"(1 – 3000) kN"}],"search_zh":"地面找平层 抗压强度 范围 PN-EN 13892-2:2004","test_object_zh":"地面找平层"},{"_id":"6a5dc9b6f1c10c8ce825cbde","lab_id":"69ad52a3de79e566650fb2b6","country":"PL","accr_number":"AB 535","accr_body":"PCA","test_object":"Podkłady podłogowe","test_object_en":"Floor screeds","methodology":"Wytrzymałość na zginanie","methodology_en":"Flexural strength","parameters":[{"name":"Zakres","range":"(1 – 100) kN"}],"parameters_en":[{"name":"Range","range":"(1 – 100) kN"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na zginanie\nZakres (1 – 100) kN","reference":"PN-EN 13892-2:2004","norm_bases":["PN-EN 13892-2:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Podkłady podłogowe Wytrzymałość na zginanie\nZakres (1 – 100) kN PN-EN 13892-2:2004 Podklady podlogowe Wytrzymalosc na zginanie\nZakres (1 – 100) kN PN-EN 13892-2:2004","categories":["other"],"row_index":24,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Floor screeds Flexural strength Range PN-EN 13892-2:2004","parameters_zh":[{"name":"范围","range":"(1 – 100) kN"}],"search_zh":"地面找平层 抗弯强度 范围 PN-EN 13892-2:2004","methodology_zh":"抗弯强度","test_object_zh":"地面找平层"},{"_id":"6a5dc9b6f1c10c8ce825cbdf","lab_id":"69ad52a3de79e566650fb2b6","country":"PL","accr_number":"AB 535","accr_body":"PCA","test_object":"Podkłady podłogowe (na bazie cementu)","test_object_en":"Floor screeds (cement-based)","methodology":"Pobieranie próbek","methodology_en":"Sampling","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek","reference":"PN-EN 13892-1:2004","norm_bases":["PN-EN 13892-1:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Podkłady podłogowe (na bazie cementu) Pobieranie próbek PN-EN 13892-1:2004 Podklady podlogowe (na bazie cementu) Pobieranie probek PN-EN 13892-1:2004","categories":["construction"],"row_index":25,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Floor screeds (cement-based) Sampling PN-EN 13892-1:2004","methodology_zh":"样品采集","search_zh":"样品采集 PN-EN 13892-1:2004"},{"_id":"6a5dc9b6f1c10c8ce825cbe0","lab_id":"69ad52a3de79e566650fb2b6","country":"PL","accr_number":"AB 535","accr_body":"PCA","test_object":"Kruszywo","test_object_en":"Aggregate","methodology":"Skład ziarnowy","methodology_en":"Particle size distribution","parameters":[{"name":"Zakres","range":"(0 – 31,5) mm"}],"parameters_en":[{"name":"Range","range":"(0 – 31,5) mm"}],"technique":"Metoda przesiewania","techniques":["Metoda przesiewania"],"technique_en":"Sieving method","computed":[],"computed_en":[],"activity":"Skład ziarnowy\nZakres (0 – 31,5) mm\nMetoda przesiewania","reference":"PN-91/B-06714/15 | PN-EN 933-1:2012","norm_bases":["PN-91/B-06714/15","PN-EN 933-1:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywo Skład ziarnowy\nZakres (0 – 31,5) mm\nMetoda przesiewania PN-91/B-06714/15 | PN-EN 933-1:2012 Kruszywo Sklad ziarnowy\nZakres (0 – 31,5) mm\nMetoda przesiewania PN-91/B-06714/15 | PN-EN 933-1:2012","categories":["construction"],"row_index":26,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Aggregate Particle size distribution Sieving method Range PN-91/B-06714/15 | PN-EN 933-1:2012","parameters_zh":[{"name":"范围","range":"(0 – 31,5) mm"}],"search_zh":"骨料 粒度分布 筛分法 范围 PN-91/B-06714/15 | PN-EN 933-1:2012","methodology_zh":"粒度分布","technique_zh":"筛分法","test_object_zh":"骨料"},{"_id":"6a5dc9b6f1c10c8ce825cbe1","lab_id":"69ad52a3de79e566650fb2b6","country":"PL","accr_number":"AB 535","accr_body":"PCA","test_object":"Kruszywo","test_object_en":"Aggregate","methodology":"Zawartość zanieczyszczeń organicznych","methodology_en":"Content of organic impurities","parameters":[],"parameters_en":[],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"technique_en":"Visual method","computed":[],"computed_en":[],"activity":"Zawartość zanieczyszczeń organicznych\nMetoda wizualna","reference":"PN-78/B-06714/26","norm_bases":["PN-78/B-06714/26"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywo Zawartość zanieczyszczeń organicznych\nMetoda wizualna PN-78/B-06714/26 Kruszywo Zawartosc zanieczyszczen organicznych\nMetoda wizualna PN-78/B-06714/26","categories":["construction"],"row_index":27,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Aggregate Content of organic impurities Visual method PN-78/B-06714/26","search_zh":"骨料 目视法 PN-78/B-06714/26","technique_zh":"目视法","test_object_zh":"骨料"},{"_id":"6a5dc9b6f1c10c8ce825cbe2","lab_id":"69ad52a3de79e566650fb2b6","country":"PL","accr_number":"AB 535","accr_body":"PCA","test_object":"Kruszywo","test_object_en":"Aggregate","methodology":"Wytrzymałość na miażdżenie (wskaźnik rozkruszenia)","methodology_en":"Crushing strength (crushing index)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na miażdżenie (wskaźnik rozkruszenia)","reference":"PN-78/B-06714/40","norm_bases":["PN-78/B-06714/40"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywo Wytrzymałość na miażdżenie (wskaźnik rozkruszenia) PN-78/B-06714/40 Kruszywo Wytrzymalosc na miazdzenie (wskaznik rozkruszenia) PN-78/B-06714/40","categories":["construction"],"row_index":28,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Aggregate Crushing strength (crushing index) PN-78/B-06714/40","search_zh":"骨料 PN-78/B-06714/40","test_object_zh":"骨料"},{"_id":"6a5dc9b6f1c10c8ce825cbe3","lab_id":"69ad52a3de79e566650fb2b6","country":"PL","accr_number":"AB 535","accr_body":"PCA","test_object":"Kruszywo","test_object_en":"Aggregate","methodology":"Mrozoodporność","methodology_en":"Frost resistance","parameters":[],"parameters_en":[],"technique":"Metoda bezpośrednia","techniques":["Metoda bezpośrednia"],"technique_en":"Direct method","computed":[],"computed_en":[],"activity":"Mrozoodporność\nMetoda bezpośrednia","reference":"PN-78/B-06714/19","norm_bases":["PN-78/B-06714/19"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywo Mrozoodporność\nMetoda bezpośrednia PN-78/B-06714/19 Kruszywo Mrozoodpornosc\nMetoda bezposrednia PN-78/B-06714/19","categories":["construction"],"row_index":29,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Aggregate Frost resistance Direct method PN-78/B-06714/19","search_zh":"骨料 抗冻性 直接法 PN-78/B-06714/19","technique_zh":"直接法","methodology_zh":"抗冻性","test_object_zh":"骨料"},{"_id":"6a5dc9b6f1c10c8ce825cbe4","lab_id":"69ad52a3de79e566650fb2b6","country":"PL","accr_number":"AB 535","accr_body":"PCA","test_object":"Kruszywo","test_object_en":"Aggregate","methodology":"Zawartość zanieczyszczeń obcych","methodology_en":"Foreign matter content","parameters":[],"parameters_en":[],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość zanieczyszczeń obcych\nMetoda wagowa","reference":"PN-76/B-06714/12","norm_bases":["PN-76/B-06714/12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywo Zawartość zanieczyszczeń obcych\nMetoda wagowa PN-76/B-06714/12 Kruszywo Zawartosc zanieczyszczen obcych\nMetoda wagowa PN-76/B-06714/12","categories":["construction"],"row_index":30,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Aggregate Foreign matter content Gravimetric method PN-76/B-06714/12","search_zh":"骨料 重量法 PN-76/B-06714/12","technique_zh":"重量法","test_object_zh":"骨料"},{"_id":"6a5dc9b6f1c10c8ce825cbe5","lab_id":"69ad52a3de79e566650fb2b6","country":"PL","accr_number":"AB 535","accr_body":"PCA","test_object":"Kruszywo","test_object_en":"Aggregate","methodology":"Kształt ziaren","methodology_en":"Particle shape","parameters":[{"name":"Zakres","range":"(2,5 – 16) mm"}],"parameters_en":[{"name":"Range","range":"(2,5 – 16) mm"}],"technique":"Metoda wskaźnika płaskości","techniques":["Metoda wskaźnika płaskości"],"technique_en":"Flakiness index method","computed":[],"computed_en":[],"activity":"Kształt ziaren\nZakres (2,5 – 16) mm\nMetoda wskaźnika płaskości","reference":"PN-EN 933-3:2012","norm_bases":["PN-EN 933-3:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywo Kształt ziaren\nZakres (2,5 – 16) mm\nMetoda wskaźnika płaskości PN-EN 933-3:2012 Kruszywo Ksztalt ziaren\nZakres (2,5 – 16) mm\nMetoda wskaznika plaskosci PN-EN 933-3:2012","categories":["construction"],"row_index":31,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Aggregate Particle shape Flakiness index method Range PN-EN 933-3:2012","parameters_zh":[{"name":"范围","range":"(2,5 – 16) mm"}],"search_zh":"骨料 范围 PN-EN 933-3:2012","test_object_zh":"骨料"},{"_id":"6a5dc9b6f1c10c8ce825cbe6","lab_id":"69ad52a3de79e566650fb2b6","country":"PL","accr_number":"AB 535","accr_body":"PCA","test_object":"Kruszywo","test_object_en":"Aggregate","methodology":"Zawartość humusu","methodology_en":"Humus content","parameters":[],"parameters_en":[],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"technique_en":"Visual method","computed":[],"computed_en":[],"activity":"Zawartość humusu\nMetoda wizualna","reference":"PN-EN 1744-1+A1:2013-05","norm_bases":["PN-EN 1744-1+A1:2013-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywo Zawartość humusu\nMetoda wizualna PN-EN 1744-1+A1:2013-05 Kruszywo Zawartosc humusu\nMetoda wizualna PN-EN 1744-1+A1:2013-05","categories":["construction"],"row_index":32,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Aggregate Humus content Visual method PN-EN 1744-1+A1:2013-05","search_zh":"骨料 目视法 PN-EN 1744-1+A1:2013-05","technique_zh":"目视法","test_object_zh":"骨料"},{"_id":"6a5dc9b6f1c10c8ce825cbe7","lab_id":"69ad52a3de79e566650fb2b6","country":"PL","accr_number":"AB 535","accr_body":"PCA","test_object":"Kruszywo","test_object_en":"Aggregate","methodology":"Zawartość pyłów mineralnych","methodology_en":"Content of mineral dusts","parameters":[],"parameters_en":[],"technique":"Metoda przesiewania","techniques":["Metoda przesiewania"],"technique_en":"Sieving method","computed":[],"computed_en":[],"activity":"Zawartość pyłów mineralnych\nMetoda przesiewania","reference":"PN-EN 933-1:2012","norm_bases":["PN-EN 933-1:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywo Zawartość pyłów mineralnych\nMetoda przesiewania PN-EN 933-1:2012 Kruszywo Zawartosc pylow mineralnych\nMetoda przesiewania PN-EN 933-1:2012","categories":["construction"],"row_index":33,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Aggregate Content of mineral dusts Sieving method PN-EN 933-1:2012","search_zh":"骨料 筛分法 PN-EN 933-1:2012","technique_zh":"筛分法","test_object_zh":"骨料"},{"_id":"6a5dc9b6f1c10c8ce825cbe8","lab_id":"69ad52a3de79e566650fb2b6","country":"PL","accr_number":"AB 535","accr_body":"PCA","test_object":"Kruszywo","test_object_en":"Aggregate","methodology":"Gęstość nasypowa w stanie luźnym i utrzęsionym","methodology_en":"Bulk density in the loose and tapped state","parameters":[],"parameters_en":[],"technique":"Metoda wagowo-objętościowa","techniques":["Metoda wagowo-objętościowa"],"technique_en":"Gravimetric-volumetric method","computed":[],"computed_en":[],"activity":"Gęstość nasypowa w stanie luźnym i utrzęsionym\nMetoda wagowo-objętościowa","reference":"PN-77/B-06714/07","norm_bases":["PN-77/B-06714/07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywo Gęstość nasypowa w stanie luźnym i utrzęsionym\nMetoda wagowo-objętościowa PN-77/B-06714/07 Kruszywo Gestosc nasypowa w stanie luznym i utrzesionym\nMetoda wagowo-objetosciowa PN-77/B-06714/07","categories":["construction"],"row_index":34,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Aggregate Bulk density in the loose and tapped state Gravimetric-volumetric method PN-77/B-06714/07","search_zh":"骨料 重量-容量法 PN-77/B-06714/07","technique_zh":"重量-容量法","test_object_zh":"骨料"},{"_id":"6a5dc9b6f1c10c8ce825cbe9","lab_id":"69ad52a3de79e566650fb2b6","country":"PL","accr_number":"AB 535","accr_body":"PCA","test_object":"Kruszywo","test_object_en":"Aggregate","methodology":"Gęstość nasypowa w stanie luźnym i utrzęsionym dla kruszywa do 31,5 mm","methodology_en":"Bulk density in the loose and tapped state for aggregate up to 31,5 mm","parameters":[],"parameters_en":[],"technique":"Metoda wagowo-objętościowa","techniques":["Metoda wagowo-objętościowa"],"technique_en":"Gravimetric-volumetric method","computed":[],"computed_en":[],"activity":"Gęstość nasypowa w stanie luźnym i utrzęsionym dla kruszywa do 31,5 mm\nMetoda wagowo-objętościowa","reference":"PN-EN 1097-3:2000","norm_bases":["PN-EN 1097-3:2000"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywo Gęstość nasypowa w stanie luźnym i utrzęsionym dla kruszywa do 31,5 mm\nMetoda wagowo-objętościowa PN-EN 1097-3:2000 Kruszywo Gestosc nasypowa w stanie luznym i utrzesionym dla kruszywa do 31,5 mm\nMetoda wagowo-objetosciowa PN-EN 1097-3:2000","categories":["construction"],"row_index":35,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Aggregate Bulk density in the loose and tapped state for aggregate up to 31,5 mm Gravimetric-volumetric method PN-EN 1097-3:2000","search_zh":"骨料 重量-容量法 PN-EN 1097-3:2000","technique_zh":"重量-容量法","test_object_zh":"骨料"},{"_id":"6a5dc9b6f1c10c8ce825cbea","lab_id":"69ad52a3de79e566650fb2b6","country":"PL","accr_number":"AB 535","accr_body":"PCA","test_object":"Kruszywo","test_object_en":"Aggregate","methodology":"Mrozoodporność","methodology_en":"Frost resistance","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Mrozoodporność","reference":"PN-EN 1367-1:2007 | PN-EN 1367-6:2008","norm_bases":["PN-EN 1367-1:2007","PN-EN 1367-6:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywo Mrozoodporność PN-EN 1367-1:2007 | PN-EN 1367-6:2008 Kruszywo Mrozoodpornosc PN-EN 1367-1:2007 | PN-EN 1367-6:2008","categories":["construction"],"row_index":36,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Aggregate Frost resistance PN-EN 1367-1:2007 | PN-EN 1367-6:2008","methodology_zh":"抗冻性","search_zh":"骨料 抗冻性 PN-EN 1367-1:2007 | PN-EN 1367-6:2008","test_object_zh":"骨料"},{"_id":"6a5dc9b6f1c10c8ce825cbeb","lab_id":"69ad52a3de79e566650fb2b6","country":"PL","accr_number":"AB 535","accr_body":"PCA","test_object":"Kruszywo","test_object_en":"Aggregate","methodology":"Reaktywność alkaliczna","methodology_en":"Alkali reactivity","parameters":[],"parameters_en":[],"technique":"Metoda beleczkowa (przyspieszona)","techniques":["Metoda beleczkowa (przyspieszona)"],"technique_en":"Bar method (accelerated)","computed":[],"computed_en":[],"activity":"Reaktywność alkaliczna\nMetoda beleczkowa (przyspieszona)","reference":"Procedura Badawcza GDDKiA PB/1/18","norm_bases":["Procedura Badawcza GDDKiA PB/1/18"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywo Reaktywność alkaliczna\nMetoda beleczkowa (przyspieszona) Procedura Badawcza GDDKiA PB/1/18 Kruszywo Reaktywnosc alkaliczna\nMetoda beleczkowa (przyspieszona) Procedura Badawcza GDDKiA PB/1/18","categories":["construction"],"row_index":37,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Aggregate Alkali reactivity Bar method (accelerated) Procedura Badawcza GDDKiA PB/1/18","search_zh":"骨料 碱活性 Procedura Badawcza GDDKiA PB/1/18","test_object_zh":"骨料","methodology_zh":"碱活性"},{"_id":"6a5dc9b6f1c10c8ce825cbec","lab_id":"69ad52a3de79e566650fb2b6","country":"PL","accr_number":"AB 535","accr_body":"PCA","test_object":"Kruszywo","test_object_en":"Aggregate","methodology":"Reaktywność alkaliczna","methodology_en":"Alkali reactivity","parameters":[],"parameters_en":[],"technique":"Metoda beleczkowa (długoterminowa)","techniques":["Metoda beleczkowa (długoterminowa)"],"technique_en":"Bar method (long-term)","computed":[],"computed_en":[],"activity":"Reaktywność alkaliczna\nMetoda beleczkowa (długoterminowa)","reference":"Procedura Badawcza GDDKiA PB/2/18","norm_bases":["Procedura Badawcza GDDKiA PB/2/18"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywo Reaktywność alkaliczna\nMetoda beleczkowa (długoterminowa) Procedura Badawcza GDDKiA PB/2/18 Kruszywo Reaktywnosc alkaliczna\nMetoda beleczkowa (dlugoterminowa) Procedura Badawcza GDDKiA PB/2/18","categories":["construction"],"row_index":38,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Aggregate Alkali reactivity Bar method (long-term) Procedura Badawcza GDDKiA PB/2/18","search_zh":"骨料 碱活性 Procedura Badawcza GDDKiA PB/2/18","test_object_zh":"骨料","methodology_zh":"碱活性"},{"_id":"6a5dc9b6f1c10c8ce825cbed","lab_id":"69ad52a3de79e566650fb2b6","country":"PL","accr_number":"AB 535","accr_body":"PCA","test_object":"Betonowe kostki brukowe","test_object_en":"Concrete paving blocks","methodology":"Wytrzymałość na rozciąganie przy rozłupywaniu","methodology_en":"Splitting tensile strength","parameters":[{"name":"Zakres","range":"(1 – 3000) kN"}],"parameters_en":[{"name":"Range","range":"(1 – 3000) kN"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na rozciąganie przy rozłupywaniu\nZakres (1 – 3000) kN","reference":"PN-EN 1338:2005+AC:2007","norm_bases":["PN-EN 1338:2005+AC:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Betonowe kostki brukowe Wytrzymałość na rozciąganie przy rozłupywaniu\nZakres (1 – 3000) kN PN-EN 1338:2005+AC:2007 Betonowe kostki brukowe Wytrzymalosc na rozciaganie przy rozlupywaniu\nZakres (1 – 3000) kN PN-EN 1338:2005+AC:2007","categories":["construction"],"row_index":39,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Concrete paving blocks Splitting tensile strength Range PN-EN 1338:2005+AC:2007","methodology_zh":"劈裂抗拉强度","parameters_zh":[{"name":"范围","range":"(1 – 3000) kN"}],"search_zh":"混凝土铺路砖 劈裂抗拉强度 范围 PN-EN 1338:2005+AC:2007","test_object_zh":"混凝土铺路砖"},{"_id":"6a5dc9b6f1c10c8ce825cbee","lab_id":"69ad52a3de79e566650fb2b6","country":"PL","accr_number":"AB 535","accr_body":"PCA","test_object":"Betonowe kostki brukowe","test_object_en":"Concrete paving blocks","methodology":"Nasiąkliwość","methodology_en":"Water absorption","parameters":[],"parameters_en":[],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Nasiąkliwość\nMetoda wagowa","reference":"PN-EN 1338:2005+AC:2007","norm_bases":["PN-EN 1338:2005+AC:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Betonowe kostki brukowe Nasiąkliwość\nMetoda wagowa PN-EN 1338:2005+AC:2007 Betonowe kostki brukowe Nasiakliwosc\nMetoda wagowa PN-EN 1338:2005+AC:2007","categories":["construction"],"row_index":40,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Concrete paving blocks Water absorption Gravimetric method PN-EN 1338:2005+AC:2007","methodology_zh":"吸水率","search_zh":"混凝土铺路砖 吸水率 重量法 PN-EN 1338:2005+AC:2007","technique_zh":"重量法","test_object_zh":"混凝土铺路砖"},{"_id":"6a5dc9b6f1c10c8ce825cbef","lab_id":"69ad52a3de79e566650fb2b6","country":"PL","accr_number":"AB 535","accr_body":"PCA","test_object":"Betonowe kostki brukowe","test_object_en":"Concrete paving blocks","methodology":"Odporność na zamrażanie/rozmrażanie z udziałem soli odladzającej","methodology_en":"Freeze/thaw resistance with de-icing salt","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na zamrażanie/rozmrażanie z udziałem soli odladzającej","reference":"PN-EN 1338:2005+AC:2007","norm_bases":["PN-EN 1338:2005+AC:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Betonowe kostki brukowe Odporność na zamrażanie/rozmrażanie z udziałem soli odladzającej PN-EN 1338:2005+AC:2007 Betonowe kostki brukowe Odpornosc na zamrazanie/rozmrazanie z udzialem soli odladzajacej PN-EN 1338:2005+AC:2007","categories":["construction"],"row_index":41,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Concrete paving blocks Freeze/thaw resistance with de-icing salt PN-EN 1338:2005+AC:2007","search_zh":"混凝土铺路砖 含除冰盐的抗冻融性 PN-EN 1338:2005+AC:2007","test_object_zh":"混凝土铺路砖","methodology_zh":"含除冰盐的抗冻融性"},{"_id":"6a5dc9b6f1c10c8ce825cbf0","lab_id":"69ad52a3de79e566650fb2b6","country":"PL","accr_number":"AB 535","accr_body":"PCA","test_object":"Betonowe płyty brukowe","test_object_en":"Concrete paving flags","methodology":"Nasiąkliwość","methodology_en":"Water absorption","parameters":[],"parameters_en":[],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Nasiąkliwość\nMetoda wagowa","reference":"PN-EN 1339:2005+AC:2007","norm_bases":["PN-EN 1339:2005+AC:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Betonowe płyty brukowe Nasiąkliwość\nMetoda wagowa PN-EN 1339:2005+AC:2007 Betonowe plyty brukowe Nasiakliwosc\nMetoda wagowa PN-EN 1339:2005+AC:2007","categories":["construction"],"row_index":42,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Concrete paving flags Water absorption Gravimetric method PN-EN 1339:2005+AC:2007","methodology_zh":"吸水率","search_zh":"混凝土路面砖 吸水率 重量法 PN-EN 1339:2005+AC:2007","technique_zh":"重量法","test_object_zh":"混凝土路面砖"},{"_id":"6a5dc9b6f1c10c8ce825cbf1","lab_id":"69ad52a3de79e566650fb2b6","country":"PL","accr_number":"AB 535","accr_body":"PCA","test_object":"Betonowe płyty brukowe","test_object_en":"Concrete paving flags","methodology":"Odporność na zamrażanie/rozmrażanie z udziałem soli odladzającej","methodology_en":"Freeze/thaw resistance with de-icing salt","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na zamrażanie/rozmrażanie z udziałem soli odladzającej","reference":"PN-EN 1339:2005+AC:2007","norm_bases":["PN-EN 1339:2005+AC:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Betonowe płyty brukowe Odporność na zamrażanie/rozmrażanie z udziałem soli odladzającej PN-EN 1339:2005+AC:2007 Betonowe plyty brukowe Odpornosc na zamrazanie/rozmrazanie z udzialem soli odladzajacej PN-EN 1339:2005+AC:2007","categories":["construction"],"row_index":43,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Concrete paving flags Freeze/thaw resistance with de-icing salt PN-EN 1339:2005+AC:2007","search_zh":"混凝土路面砖 含除冰盐的抗冻融性 PN-EN 1339:2005+AC:2007","test_object_zh":"混凝土路面砖","methodology_zh":"含除冰盐的抗冻融性"},{"_id":"6a5dc9b6f1c10c8ce825cbf2","lab_id":"69ad52a3de79e566650fb2b6","country":"PL","accr_number":"AB 535","accr_body":"PCA","test_object":"Krawężniki i obrzeża betonowe","test_object_en":"Concrete kerb units and edgings","methodology":"Wytrzymałość na zginanie","methodology_en":"Flexural strength","parameters":[{"name":"Zakres","range":"(1 – 100) kN"}],"parameters_en":[{"name":"Range","range":"(1 – 100) kN"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na zginanie\nZakres (1 – 100) kN","reference":"PN-EN 1340:2004+AC:2007","norm_bases":["PN-EN 1340:2004+AC:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Krawężniki i obrzeża betonowe Wytrzymałość na zginanie\nZakres (1 – 100) kN PN-EN 1340:2004+AC:2007 Krawezniki i obrzeza betonowe Wytrzymalosc na zginanie\nZakres (1 – 100) kN PN-EN 1340:2004+AC:2007","categories":["construction"],"row_index":44,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Concrete kerb units and edgings Flexural strength Range PN-EN 1340:2004+AC:2007","parameters_zh":[{"name":"范围","range":"(1 – 100) kN"}],"search_zh":"混凝土路缘石与边石 抗弯强度 范围 PN-EN 1340:2004+AC:2007","methodology_zh":"抗弯强度","test_object_zh":"混凝土路缘石与边石"},{"_id":"6a5dc9b6f1c10c8ce825cbf3","lab_id":"69ad52a3de79e566650fb2b6","country":"PL","accr_number":"AB 535","accr_body":"PCA","test_object":"Krawężniki i obrzeża betonowe","test_object_en":"Concrete kerb units and edgings","methodology":"Nasiąkliwość","methodology_en":"Water absorption","parameters":[],"parameters_en":[],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Nasiąkliwość\nMetoda wagowa","reference":"PN-EN 1340:2004+AC:2007","norm_bases":["PN-EN 1340:2004+AC:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Krawężniki i obrzeża betonowe Nasiąkliwość\nMetoda wagowa PN-EN 1340:2004+AC:2007 Krawezniki i obrzeza betonowe Nasiakliwosc\nMetoda wagowa PN-EN 1340:2004+AC:2007","categories":["construction"],"row_index":45,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Concrete kerb units and edgings Water absorption Gravimetric method PN-EN 1340:2004+AC:2007","methodology_zh":"吸水率","search_zh":"混凝土路缘石与边石 吸水率 重量法 PN-EN 1340:2004+AC:2007","technique_zh":"重量法","test_object_zh":"混凝土路缘石与边石"},{"_id":"6a5dc9b6f1c10c8ce825cbf4","lab_id":"69ad52a3de79e566650fb2b6","country":"PL","accr_number":"AB 535","accr_body":"PCA","test_object":"Krawężniki i obrzeża betonowe","test_object_en":"Concrete kerb units and edgings","methodology":"Odporność na zamrażanie/rozmrażanie z udziałem soli odladzającej","methodology_en":"Freeze/thaw resistance with de-icing salt","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na zamrażanie/rozmrażanie z udziałem soli odladzającej","reference":"PN-EN 1340:2004+AC:2007","norm_bases":["PN-EN 1340:2004+AC:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Krawężniki i obrzeża betonowe Odporność na zamrażanie/rozmrażanie z udziałem soli odladzającej PN-EN 1340:2004+AC:2007 Krawezniki i obrzeza betonowe Odpornosc na zamrazanie/rozmrazanie z udzialem soli odladzajacej PN-EN 1340:2004+AC:2007","categories":["construction"],"row_index":46,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Concrete kerb units and edgings Freeze/thaw resistance with de-icing salt PN-EN 1340:2004+AC:2007","search_zh":"混凝土路缘石与边石 含除冰盐的抗冻融性 PN-EN 1340:2004+AC:2007","test_object_zh":"混凝土路缘石与边石","methodology_zh":"含除冰盐的抗冻融性"},{"_id":"6a5dc9b6f1c10c8ce825cbf5","lab_id":"69ad52a3de79e566650fb2b6","country":"PL","accr_number":"AB 535","accr_body":"PCA","test_object":"Podłoże i nasypy","test_object_en":"Subgrade and embankments","methodology":"Moduł odkształcenia","methodology_en":"Deformation modulus","parameters":[{"name":"Zakres","range":"(0,02 – 0,35) MPa"}],"parameters_en":[{"name":"Range","range":"(0,02 – 0,35) MPa"}],"technique":"Metoda obciążeń płytą VSS","techniques":["Metoda obciążeń płytą VSS"],"technique_en":"VSS plate loading method","computed":[],"computed_en":[],"activity":"Moduł odkształcenia\nZakres (0,02 – 0,35) MPa\nMetoda obciążeń płytą VSS","reference":"BN-64/8931-02 | PN-S-02205:1998 Warunki techniczne PKP PLK Id-32009 KPRNPP-2013 GDDKiA Załącznik B3 | Instrukcja GDDP 1998","norm_bases":["BN-64/8931-02","PN-S-02205:1998 Warunki techniczne PKP PLK Id-32009 KPRNPP-2013 GDDKiA Załącznik B3","Instrukcja GDDP 1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Podłoże i nasypy Moduł odkształcenia\nZakres (0,02 – 0,35) MPa\nMetoda obciążeń płytą VSS BN-64/8931-02 | PN-S-02205:1998 Warunki techniczne PKP PLK Id-32009 KPRNPP-2013 GDDKiA Załącznik B3 | Instrukcja GDDP 1998 Podloze i nasypy Modul odksztalcenia\nZakres (0,02 – 0,35) MPa\nMetoda obciazen plyta VSS BN-64/8931-02 | PN-S-02205:1998 Warunki techniczne PKP PLK Id-32009 KPRNPP-2013 GDDKiA Zalacznik B3 | Instrukcja GDDP 1998","categories":["other"],"row_index":47,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Subgrade and embankments Deformation modulus VSS plate loading method Range BN-64/8931-02 | PN-S-02205:1998 Warunki techniczne PKP PLK Id-32009 KPRNPP-2013 GDDKiA Załącznik B3 | Instrukcja GDDP 1998","parameters_zh":[{"name":"范围","range":"(0,02 – 0,35) MPa"}],"search_zh":"变形模量 VSS 平板荷载法 范围 BN-64/8931-02 | PN-S-02205:1998 Warunki techniczne PKP PLK Id-32009 KPRNPP-2013 GDDKiA Załącznik B3 | Instrukcja GDDP 1998","methodology_zh":"变形模量","technique_zh":"VSS 平板荷载法"},{"_id":"6a5dc9b6f1c10c8ce825cbf6","lab_id":"69ad52a3de79e566650fb2b6","country":"PL","accr_number":"AB 535","accr_body":"PCA","test_object":"Warstwy konstrukcyjne nawierzchni i zasypki","test_object_en":"Pavement structural layers and backfills","methodology":"Moduł odkształcenia","methodology_en":"Deformation modulus","parameters":[{"name":"Zakres","range":"(0,02 – 0,45) MPa"}],"parameters_en":[{"name":"Range","range":"(0,02 – 0,45) MPa"}],"technique":"Metoda obciążeń płytą VSS","techniques":["Metoda obciążeń płytą VSS"],"technique_en":"VSS plate loading method","computed":[],"computed_en":[],"activity":"Moduł odkształcenia\nZakres (0,02 – 0,45) MPa\nMetoda obciążeń płytą VSS","reference":"BN-64/8931-02 | PN-S-02205:1998 Warunki techniczne PKP PLK Id-32009 KPRNPP-2013 GDDKiA Załącznik B3 | Instrukcja GDDP 1998","norm_bases":["BN-64/8931-02","PN-S-02205:1998 Warunki techniczne PKP PLK Id-32009 KPRNPP-2013 GDDKiA Załącznik B3","Instrukcja GDDP 1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Warstwy konstrukcyjne nawierzchni i zasypki Moduł odkształcenia\nZakres (0,02 – 0,45) MPa\nMetoda obciążeń płytą VSS BN-64/8931-02 | PN-S-02205:1998 Warunki techniczne PKP PLK Id-32009 KPRNPP-2013 GDDKiA Załącznik B3 | Instrukcja GDDP 1998 Warstwy konstrukcyjne nawierzchni i zasypki Modul odksztalcenia\nZakres (0,02 – 0,45) MPa\nMetoda obciazen plyta VSS BN-64/8931-02 | PN-S-02205:1998 Warunki techniczne PKP PLK Id-32009 KPRNPP-2013 GDDKiA Zalacznik B3 | Instrukcja GDDP 1998","categories":["other"],"row_index":48,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Pavement structural layers and backfills Deformation modulus VSS plate loading method Range BN-64/8931-02 | PN-S-02205:1998 Warunki techniczne PKP PLK Id-32009 KPRNPP-2013 GDDKiA Załącznik B3 | Instrukcja GDDP 1998","parameters_zh":[{"name":"范围","range":"(0,02 – 0,45) MPa"}],"search_zh":"变形模量 VSS 平板荷载法 范围 BN-64/8931-02 | PN-S-02205:1998 Warunki techniczne PKP PLK Id-32009 KPRNPP-2013 GDDKiA Załącznik B3 | Instrukcja GDDP 1998","methodology_zh":"变形模量","technique_zh":"VSS 平板荷载法"},{"_id":"6a5dc9b6f1c10c8ce825cbf7","lab_id":"69ad52a3de79e566650fb2b6","country":"PL","accr_number":"AB 535","accr_body":"PCA","test_object":"Domieszki do betonu","test_object_en":"Admixtures for concrete","methodology":"Zmniejszenie ilości wody zarobowej","methodology_en":"Reduction of mixing water","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Zmniejszenie ilości wody zarobowej","reference":"PN-EN 480-1:2014-12 | PN-EN 12350-2:2011 | PN-EN 12350-2:2019-07","norm_bases":["PN-EN 480-1:2014-12","PN-EN 12350-2:2011","PN-EN 12350-2:2019-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Domieszki do betonu Zmniejszenie ilości wody zarobowej PN-EN 480-1:2014-12 | PN-EN 12350-2:2011 | PN-EN 12350-2:2019-07 Domieszki do betonu Zmniejszenie ilosci wody zarobowej PN-EN 480-1:2014-12 | PN-EN 12350-2:2011 | PN-EN 12350-2:2019-07","categories":["construction","water"],"row_index":49,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Admixtures for concrete Reduction of mixing water PN-EN 480-1:2014-12 | PN-EN 12350-2:2011 | PN-EN 12350-2:2019-07","search_zh":"混凝土外加剂 PN-EN 480-1:2014-12 | PN-EN 12350-2:2011 | PN-EN 12350-2:2019-07","test_object_zh":"混凝土外加剂"},{"_id":"6a5dc9b6f1c10c8ce825cbf8","lab_id":"69ad52a3de79e566650fb2b6","country":"PL","accr_number":"AB 535","accr_body":"PCA","test_object":"Domieszki do betonu","test_object_en":"Admixtures for concrete","methodology":"Wytrzymałość na ściskanie","methodology_en":"Compressive strength","parameters":[{"name":"Zakres","range":"(1 – 3000) kN"}],"parameters_en":[{"name":"Range","range":"(1 – 3000) kN"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ściskanie\nZakres (1 – 3000) kN","reference":"PN-EN 480-1:2014-12 | PN-EN 12390-3:2011+AC:2012 | PN-EN 12390-3:2019-07","norm_bases":["PN-EN 480-1:2014-12","PN-EN 12390-3:2011+AC:2012","PN-EN 12390-3:2019-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Domieszki do betonu Wytrzymałość na ściskanie\nZakres (1 – 3000) kN PN-EN 480-1:2014-12 | PN-EN 12390-3:2011+AC:2012 | PN-EN 12390-3:2019-07 Domieszki do betonu Wytrzymalosc na sciskanie\nZakres (1 – 3000) kN PN-EN 480-1:2014-12 | PN-EN 12390-3:2011+AC:2012 | PN-EN 12390-3:2019-07","categories":["construction"],"row_index":50,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Admixtures for concrete Compressive strength Range PN-EN 480-1:2014-12 | PN-EN 12390-3:2011+AC:2012 | PN-EN 12390-3:2019-07","methodology_zh":"抗压强度","parameters_zh":[{"name":"范围","range":"(1 – 3000) kN"}],"search_zh":"混凝土外加剂 抗压强度 范围 PN-EN 480-1:2014-12 | PN-EN 12390-3:2011+AC:2012 | PN-EN 12390-3:2019-07","test_object_zh":"混凝土外加剂"},{"_id":"6a5dc9b6f1c10c8ce825cbf9","lab_id":"69ad52a3de79e566650fb2b6","country":"PL","accr_number":"AB 535","accr_body":"PCA","test_object":"Domieszki do betonu","test_object_en":"Admixtures for concrete","methodology":"Zawartość powietrza w mieszance betonowej","methodology_en":"Air content in the concrete mix","parameters":[{"name":"Zakres","range":"(0 – 50) %"}],"parameters_en":[{"name":"Range","range":"(0 – 50) %"}],"technique":"Metoda ciśnieniomierza","techniques":["Metoda ciśnieniomierza"],"technique_en":"Pressure gauge method","computed":[],"computed_en":[],"activity":"Zawartość powietrza w mieszance betonowej\nZakres (0 – 50) %\nMetoda ciśnieniomierza","reference":"PN-EN 480-1:2014-12 | PN-EN 12350-7:2011 | PN-EN 12350-7:2019-08","norm_bases":["PN-EN 480-1:2014-12","PN-EN 12350-7:2011","PN-EN 12350-7:2019-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Domieszki do betonu Zawartość powietrza w mieszance betonowej\nZakres (0 – 50) %\nMetoda ciśnieniomierza PN-EN 480-1:2014-12 | PN-EN 12350-7:2011 | PN-EN 12350-7:2019-08 Domieszki do betonu Zawartosc powietrza w mieszance betonowej\nZakres (0 – 50) %\nMetoda cisnieniomierza PN-EN 480-1:2014-12 | PN-EN 12350-7:2011 | PN-EN 12350-7:2019-08","categories":["construction"],"row_index":51,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Admixtures for concrete Air content in the concrete mix Pressure gauge method Range PN-EN 480-1:2014-12 | PN-EN 12350-7:2011 | PN-EN 12350-7:2019-08","parameters_zh":[{"name":"范围","range":"(0 – 50) %"}],"search_zh":"混凝土外加剂 压力计法 范围 PN-EN 480-1:2014-12 | PN-EN 12350-7:2011 | PN-EN 12350-7:2019-08","technique_zh":"压力计法","test_object_zh":"混凝土外加剂"},{"_id":"6a5dc9b6f1c10c8ce825cbfa","lab_id":"69ad52a3de79e566650fb2b6","country":"PL","accr_number":"AB 535","accr_body":"PCA","test_object":"Domieszki do betonu","test_object_en":"Admixtures for concrete","methodology":"Zwiększenie konsystencji","methodology_en":"Increase in consistency","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Zwiększenie konsystencji","reference":"PN-EN 480-1:2014-12 | PN-EN 12350-2:2011 | PN-EN 12350-2:2019-07","norm_bases":["PN-EN 480-1:2014-12","PN-EN 12350-2:2011","PN-EN 12350-2:2019-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Domieszki do betonu Zwiększenie konsystencji PN-EN 480-1:2014-12 | PN-EN 12350-2:2011 | PN-EN 12350-2:2019-07 Domieszki do betonu Zwiekszenie konsystencji PN-EN 480-1:2014-12 | PN-EN 12350-2:2011 | PN-EN 12350-2:2019-07","categories":["construction"],"row_index":52,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Admixtures for concrete Increase in consistency PN-EN 480-1:2014-12 | PN-EN 12350-2:2011 | PN-EN 12350-2:2019-07","search_zh":"混凝土外加剂 PN-EN 480-1:2014-12 | PN-EN 12350-2:2011 | PN-EN 12350-2:2019-07","test_object_zh":"混凝土外加剂"},{"_id":"6a5dc9b6f1c10c8ce825cbfb","lab_id":"69ad52a3de79e566650fb2b6","country":"PL","accr_number":"AB 535","accr_body":"PCA","test_object":"Domieszki do betonu","test_object_en":"Admixtures for concrete","methodology":"Utrzymanie konsystencji w czasie","methodology_en":"Retention of consistency over time","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Utrzymanie konsystencji w czasie","reference":"PN-EN 480-1:2014-12 | PN-EN 12350-2:2011 | PN-EN 12350-2:2019-07","norm_bases":["PN-EN 480-1:2014-12","PN-EN 12350-2:2011","PN-EN 12350-2:2019-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Domieszki do betonu Utrzymanie konsystencji w czasie PN-EN 480-1:2014-12 | PN-EN 12350-2:2011 | PN-EN 12350-2:2019-07 Domieszki do betonu Utrzymanie konsystencji w czasie PN-EN 480-1:2014-12 | PN-EN 12350-2:2011 | PN-EN 12350-2:2019-07","categories":["construction"],"row_index":53,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Admixtures for concrete Retention of consistency over time PN-EN 480-1:2014-12 | PN-EN 12350-2:2011 | PN-EN 12350-2:2019-07","search_zh":"混凝土外加剂 PN-EN 480-1:2014-12 | PN-EN 12350-2:2011 | PN-EN 12350-2:2019-07","test_object_zh":"混凝土外加剂"},{"_id":"6a5dc9b6f1c10c8ce825cbfc","lab_id":"69ad52a3de79e566650fb2b6","country":"PL","accr_number":"AB 535","accr_body":"PCA","test_object":"Elementy ścienne drobnowymiarowe – bloczki","test_object_en":"Small-sized wall units – blocks","methodology":"Mrozoodporność","methodology_en":"Frost resistance","parameters":[],"parameters_en":[],"technique":"Metoda bezpośrednia","techniques":["Metoda bezpośrednia"],"technique_en":"Direct method","computed":[],"computed_en":[],"activity":"Mrozoodporność\nMetoda bezpośrednia","reference":"PN-B-19306:2004","norm_bases":["PN-B-19306:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy ścienne drobnowymiarowe – bloczki Mrozoodporność\nMetoda bezpośrednia PN-B-19306:2004 Elementy scienne drobnowymiarowe – bloczki Mrozoodpornosc\nMetoda bezposrednia PN-B-19306:2004","categories":["other"],"row_index":54,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Small-sized wall units – blocks Frost resistance Direct method PN-B-19306:2004","search_zh":"抗冻性 直接法 PN-B-19306:2004","technique_zh":"直接法","methodology_zh":"抗冻性"},{"_id":"6a5dc9b6f1c10c8ce825cbfd","lab_id":"69ad52a3de79e566650fb2b6","country":"PL","accr_number":"AB 535","accr_body":"PCA","test_object":"Elementy ścienne drobnowymiarowe – pustaki","test_object_en":"Small-sized wall units – hollow blocks","methodology":"Mrozoodporność","methodology_en":"Frost resistance","parameters":[],"parameters_en":[],"technique":"Metoda bezpośrednia","techniques":["Metoda bezpośrednia"],"technique_en":"Direct method","computed":[],"computed_en":[],"activity":"Mrozoodporność\nMetoda bezpośrednia","reference":"PN-B-19307:2004","norm_bases":["PN-B-19307:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy ścienne drobnowymiarowe – pustaki Mrozoodporność\nMetoda bezpośrednia PN-B-19307:2004 Elementy scienne drobnowymiarowe – pustaki Mrozoodpornosc\nMetoda bezposrednia PN-B-19307:2004","categories":["other"],"row_index":55,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Small-sized wall units – hollow blocks Frost resistance Direct method PN-B-19307:2004","search_zh":"抗冻性 直接法 PN-B-19307:2004","technique_zh":"直接法","methodology_zh":"抗冻性"},{"_id":"6a5dc9b6f1c10c8ce825cbfe","lab_id":"69ad52a3de79e566650fb2b6","country":"PL","accr_number":"AB 535","accr_body":"PCA","test_object":"Elementy murowe","test_object_en":"Masonry units","methodology":"Wymiary, kształt i budowa (wysokość, szerokość, długość, grubość ścianek, drążenia, głębokość otworów, zagłębienia)","methodology_en":"Dimensions, shape and configuration (height, width, length, wall thickness, hollows, depth of holes, recesses)","parameters":[{"name":"Zakres","range":"(0 – 800) mm"}],"parameters_en":[{"name":"Range","range":"(0 – 800) mm"}],"technique":"Metoda bezpośredniego pomiaru","techniques":["Metoda bezpośredniego pomiaru"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Wymiary, kształt i budowa (wysokość, szerokość, długość, grubość ścianek, drążenia, głębokość otworów, zagłębienia)\nZakres (0 – 800) mm\nMetoda bezpośredniego pomiaru","reference":"PN-EN 772-16:2011","norm_bases":["PN-EN 772-16:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy murowe Wymiary, kształt i budowa (wysokość, szerokość, długość, grubość ścianek, drążenia, głębokość otworów, zagłębienia)\nZakres (0 – 800) mm\nMetoda bezpośredniego pomiaru PN-EN 772-16:2011 Elementy murowe Wymiary, ksztalt i budowa (wysokosc, szerokosc, dlugosc, grubosc scianek, drazenia, glebokosc otworow, zaglebienia)\nZakres (0 – 800) mm\nMetoda bezposredniego pomiaru PN-EN 772-16:2011","categories":["other"],"row_index":56,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Masonry units Dimensions, shape and configuration (height, width, length, wall thickness, hollows, depth of holes, recesses) Direct measurement method Range PN-EN 772-16:2011","parameters_zh":[{"name":"范围","range":"(0 – 800) mm"}],"search_zh":"砌块 直接测量法 范围 PN-EN 772-16:2011","technique_zh":"直接测量法","test_object_zh":"砌块"},{"_id":"6a5dc9b6f1c10c8ce825cbff","lab_id":"69ad52a3de79e566650fb2b6","country":"PL","accr_number":"AB 535","accr_body":"PCA","test_object":"Elementy murowe","test_object_en":"Masonry units","methodology":"Gęstość netto i brutto","methodology_en":"Net and gross density","parameters":[{"name":"Zakres","range":"elementy z betonu"},{"name":"kruszywowego (z kruszywami zwykłymi i lekkimi)"}],"parameters_en":[{"name":"Range","range":"elementy z betonu"},{"name":"aggregate (with normal and lightweight aggregates)"}],"technique":"Metoda wagowo-objętościowa","techniques":["Metoda wagowo-objętościowa"],"technique_en":"Gravimetric-volumetric method","computed":[],"computed_en":[],"activity":"Gęstość netto i brutto\nZakres:\nZakres elementy z betonu\nkruszywowego (z kruszywami zwykłymi i lekkimi)\nMetoda wagowo-objętościowa","reference":"PN-EN 772-13:2001","norm_bases":["PN-EN 772-13:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy murowe Gęstość netto i brutto\nZakres:\nZakres elementy z betonu\nkruszywowego (z kruszywami zwykłymi i lekkimi)\nMetoda wagowo-objętościowa PN-EN 772-13:2001 Elementy murowe Gestosc netto i brutto\nZakres:\nZakres elementy z betonu\nkruszywowego (z kruszywami zwyklymi i lekkimi)\nMetoda wagowo-objetosciowa PN-EN 772-13:2001","categories":["construction"],"row_index":57,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Masonry units Net and gross density Gravimetric-volumetric method Range aggregate (with normal and lightweight aggregates) PN-EN 772-13:2001","parameters_zh":[{"name":"范围","range":"elementy z betonu"},{"name":"kruszywowego (z kruszywami zwykłymi i lekkimi)"}],"search_zh":"砌块 重量-容量法 范围 PN-EN 772-13:2001","technique_zh":"重量-容量法","test_object_zh":"砌块"},{"_id":"6a5dc9b6f1c10c8ce825cc00","lab_id":"69ad52a3de79e566650fb2b6","country":"PL","accr_number":"AB 535","accr_body":"PCA","test_object":"Elementy murowe","test_object_en":"Masonry units","methodology":"Wytrzymałość na ściskanie","methodology_en":"Compressive strength","parameters":[{"name":"Zakres","range":"(50 – 3000) kN"}],"parameters_en":[{"name":"Range","range":"(50 – 3000) kN"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ściskanie\nZakres (50 – 3000) kN","reference":"PN-EN 772-1+A1:2015-10","norm_bases":["PN-EN 772-1+A1:2015-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy murowe Wytrzymałość na ściskanie\nZakres (50 – 3000) kN PN-EN 772-1+A1:2015-10 Elementy murowe Wytrzymalosc na sciskanie\nZakres (50 – 3000) kN PN-EN 772-1+A1:2015-10","categories":["other"],"row_index":58,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Masonry units Compressive strength Range PN-EN 772-1+A1:2015-10","methodology_zh":"抗压强度","parameters_zh":[{"name":"范围","range":"(50 – 3000) kN"}],"search_zh":"砌块 抗压强度 范围 PN-EN 772-1+A1:2015-10","test_object_zh":"砌块"},{"_id":"6a5dc9b6f1c10c8ce825cc01","lab_id":"69ad52a3de79e566650fb2b6","country":"PL","accr_number":"AB 535","accr_body":"PCA","test_object":"Elementy murowe","test_object_en":"Masonry units","methodology":"Odporność na zamrażanie-odmrażanie elementów murowych silikatowych","methodology_en":"Freeze-thaw resistance of calcium silicate masonry units","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na zamrażanie-odmrażanie elementów murowych silikatowych","reference":"PN-EN 772-18:2011","norm_bases":["PN-EN 772-18:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy murowe Odporność na zamrażanie-odmrażanie elementów murowych silikatowych PN-EN 772-18:2011 Elementy murowe Odpornosc na zamrazanie-odmrazanie elementow murowych silikatowych PN-EN 772-18:2011","categories":["other"],"row_index":59,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Masonry units Freeze-thaw resistance of calcium silicate masonry units PN-EN 772-18:2011","search_zh":"砌块 PN-EN 772-18:2011","test_object_zh":"砌块"},{"_id":"6a5dc9b6f1c10c8ce825cc02","lab_id":"69ad52a3de79e566650fb2b6","country":"PL","accr_number":"AB 535","accr_body":"PCA","test_object":"Podbudowa i ulepszone podłoże z gruntu stabilizowanego cementem","test_object_en":"Sub-base and improved subgrade of cement-stabilised soil","methodology":"Wytrzymałość na ściskanie","methodology_en":"Compressive strength","parameters":[{"name":"Zakres","range":"(1 – 3000) kN"}],"parameters_en":[{"name":"Range","range":"(1 – 3000) kN"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ściskanie\nZakres (1 – 3000) kN","reference":"PN-S-96012:1997","norm_bases":["PN-S-96012:1997"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Podbudowa i ulepszone podłoże z gruntu stabilizowanego cementem Wytrzymałość na ściskanie\nZakres (1 – 3000) kN PN-S-96012:1997 Podbudowa i ulepszone podloze z gruntu stabilizowanego cementem Wytrzymalosc na sciskanie\nZakres (1 – 3000) kN PN-S-96012:1997","categories":["construction"],"row_index":60,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sub-base and improved subgrade of cement-stabilised soil Compressive strength Range PN-S-96012:1997","methodology_zh":"抗压强度","parameters_zh":[{"name":"范围","range":"(1 – 3000) kN"}],"search_zh":"抗压强度 范围 PN-S-96012:1997"},{"_id":"6a5dc9b6f1c10c8ce825cc03","lab_id":"69ad52a3de79e566650fb2b6","country":"PL","accr_number":"AB 535","accr_body":"PCA","test_object":"Podbudowa z chudego betonu","test_object_en":"Lean concrete base course","methodology":"Wytrzymałość na ściskanie","methodology_en":"Compressive strength","parameters":[{"name":"Zakres","range":"(1 – 3000) kN"}],"parameters_en":[{"name":"Range","range":"(1 – 3000) kN"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ściskanie\nZakres (1 – 3000) kN","reference":"PN-S-96013:1997","norm_bases":["PN-S-96013:1997"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Podbudowa z chudego betonu Wytrzymałość na ściskanie\nZakres (1 – 3000) kN PN-S-96013:1997 Podbudowa z chudego betonu Wytrzymalosc na sciskanie\nZakres (1 – 3000) kN PN-S-96013:1997","categories":["construction"],"row_index":61,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Lean concrete base course Compressive strength Range PN-S-96013:1997","methodology_zh":"抗压强度","parameters_zh":[{"name":"范围","range":"(1 – 3000) kN"}],"search_zh":"抗压强度 范围 PN-S-96013:1997"},{"_id":"6a5dc9b6f1c10c8ce825cc04","lab_id":"69ad52a3de79e566650fb2b6","country":"PL","accr_number":"AB 535","accr_body":"PCA","test_object":"Kanały odwadniające nawierzchnię – kratki – pokrywy – korytka","test_object_en":"Pavement drainage channels – gratings – covers – channels","methodology":"Obciążenie próbne","methodology_en":"Proof load","parameters":[{"name":"Zakres","range":"(1 – 3000) kN"}],"parameters_en":[{"name":"Range","range":"(1 – 3000) kN"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Obciążenie próbne\nZakres (1 – 3000) kN","reference":"PN-EN 1433:2005 „N” | PN-EN 1433:2005/A1:2007 „N”","norm_bases":["PN-EN 1433:2005 „N”","PN-EN 1433:2005/A1:2007 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kanały odwadniające nawierzchnię – kratki – pokrywy – korytka Obciążenie próbne\nZakres (1 – 3000) kN PN-EN 1433:2005 „N” | PN-EN 1433:2005/A1:2007 „N” Kanaly odwadniajace nawierzchnie – kratki – pokrywy – korytka Obciazenie probne\nZakres (1 – 3000) kN PN-EN 1433:2005 „N” | PN-EN 1433:2005/A1:2007 „N”","categories":["other"],"row_index":62,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Pavement drainage channels – gratings – covers – channels Proof load Range PN-EN 1433:2005 „N” | PN-EN 1433:2005/A1:2007 „N”","parameters_zh":[{"name":"范围","range":"(1 – 3000) kN"}],"search_zh":"路面排水沟 － 格栅 － 盖板 － 沟槽 范围 PN-EN 1433:2005 „N” | PN-EN 1433:2005/A1:2007 „N”","test_object_zh":"路面排水沟 － 格栅 － 盖板 － 沟槽"},{"_id":"6a5dc9b6f1c10c8ce825cc05","lab_id":"69ad52a3de79e566650fb2b6","country":"PL","accr_number":"AB 535","accr_body":"PCA","test_object":"Kanały odwadniające nawierzchnię – kratki – pokrywy – korytka","test_object_en":"Pavement drainage channels – gratings – covers – channels","methodology":"Odkształcenia trwałe","methodology_en":"Permanent deformations","parameters":[{"name":"Zakres","range":"(1 – 3000) kN"}],"parameters_en":[{"name":"Range","range":"(1 – 3000) kN"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odkształcenia trwałe\nZakres (1 – 3000) kN","reference":"PN-EN 1433:2005 „N” | PN-EN 1433:2005/A1:2007 „N”","norm_bases":["PN-EN 1433:2005 „N”","PN-EN 1433:2005/A1:2007 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kanały odwadniające nawierzchnię – kratki – pokrywy – korytka Odkształcenia trwałe\nZakres (1 – 3000) kN PN-EN 1433:2005 „N” | PN-EN 1433:2005/A1:2007 „N” Kanaly odwadniajace nawierzchnie – kratki – pokrywy – korytka Odksztalcenia trwale\nZakres (1 – 3000) kN PN-EN 1433:2005 „N” | PN-EN 1433:2005/A1:2007 „N”","categories":["other"],"row_index":63,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Pavement drainage channels – gratings – covers – channels Permanent deformations Range PN-EN 1433:2005 „N” | PN-EN 1433:2005/A1:2007 „N”","parameters_zh":[{"name":"范围","range":"(1 – 3000) kN"}],"search_zh":"路面排水沟 － 格栅 － 盖板 － 沟槽 范围 PN-EN 1433:2005 „N” | PN-EN 1433:2005/A1:2007 „N”","test_object_zh":"路面排水沟 － 格栅 － 盖板 － 沟槽"},{"_id":"6a5dc9b6f1c10c8ce825cc06","lab_id":"69ad52a3de79e566650fb2b6","country":"PL","accr_number":"AB 535","accr_body":"PCA","test_object":"Kanały odwadniające nawierzchnię – kratki – pokrywy – korytka","test_object_en":"Pavement drainage channels – gratings – covers – channels","methodology":"Wodoszczelność – połączenia korytek odpływowych","methodology_en":"Watertightness – joints of drainage channels","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wodoszczelność – połączenia korytek odpływowych","reference":"PN-EN 1433:2005 „N” | PN-EN 1433:2005/A1:2007 „N”","norm_bases":["PN-EN 1433:2005 „N”","PN-EN 1433:2005/A1:2007 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kanały odwadniające nawierzchnię – kratki – pokrywy – korytka Wodoszczelność – połączenia korytek odpływowych PN-EN 1433:2005 „N” | PN-EN 1433:2005/A1:2007 „N” Kanaly odwadniajace nawierzchnie – kratki – pokrywy – korytka Wodoszczelnosc – polaczenia korytek odplywowych PN-EN 1433:2005 „N” | PN-EN 1433:2005/A1:2007 „N”","categories":["other"],"row_index":64,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Pavement drainage channels – gratings – covers – channels Watertightness – joints of drainage channels PN-EN 1433:2005 „N” | PN-EN 1433:2005/A1:2007 „N”","search_zh":"路面排水沟 － 格栅 － 盖板 － 沟槽 PN-EN 1433:2005 „N” | PN-EN 1433:2005/A1:2007 „N”","test_object_zh":"路面排水沟 － 格栅 － 盖板 － 沟槽"},{"_id":"6a5dc9b6f1c10c8ce825cc07","lab_id":"69ad52a3de79e566650fb2b6","country":"PL","accr_number":"AB 535","accr_body":"PCA","test_object":"Kanały odwadniające nawierzchnię – kratki – pokrywy – korytka","test_object_en":"Pavement drainage channels – gratings – covers – channels","methodology":"Trwałość – nasiąkliwość","methodology_en":"Durability – water absorption","parameters":[],"parameters_en":[],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Trwałość – nasiąkliwość\nMetoda wagowa","reference":"PN-EN 1433:2005 „N” | PN-EN 1433:2005/A1:2007 „N”","norm_bases":["PN-EN 1433:2005 „N”","PN-EN 1433:2005/A1:2007 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kanały odwadniające nawierzchnię – kratki – pokrywy – korytka Trwałość – nasiąkliwość\nMetoda wagowa PN-EN 1433:2005 „N” | PN-EN 1433:2005/A1:2007 „N” Kanaly odwadniajace nawierzchnie – kratki – pokrywy – korytka Trwalosc – nasiakliwosc\nMetoda wagowa PN-EN 1433:2005 „N” | PN-EN 1433:2005/A1:2007 „N”","categories":["other"],"row_index":65,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Pavement drainage channels – gratings – covers – channels Durability – water absorption Gravimetric method PN-EN 1433:2005 „N” | PN-EN 1433:2005/A1:2007 „N”","search_zh":"路面排水沟 － 格栅 － 盖板 － 沟槽 重量法 PN-EN 1433:2005 „N” | PN-EN 1433:2005/A1:2007 „N”","technique_zh":"重量法","test_object_zh":"路面排水沟 － 格栅 － 盖板 － 沟槽"},{"_id":"6a5dc9b6f1c10c8ce825cc08","lab_id":"69ad52a3de79e566650fb2b6","country":"PL","accr_number":"AB 535","accr_body":"PCA","test_object":"Kanały odwadniające nawierzchnię – kratki – pokrywy – korytka","test_object_en":"Pavement drainage channels – gratings – covers – channels","methodology":"Trwałość – odporność na zamrażanie/rozmrażanie w soli odladzającej","methodology_en":"Durability – resistance to freezing/thawing in de-icing salt","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Trwałość – odporność na zamrażanie/rozmrażanie w soli odladzającej","reference":"PN-EN 1433:2005 „N” | PN-EN 1433:2005/A1:2007 „N”","norm_bases":["PN-EN 1433:2005 „N”","PN-EN 1433:2005/A1:2007 „N”"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kanały odwadniające nawierzchnię – kratki – pokrywy – korytka Trwałość – odporność na zamrażanie/rozmrażanie w soli odladzającej PN-EN 1433:2005 „N” | PN-EN 1433:2005/A1:2007 „N” Kanaly odwadniajace nawierzchnie – kratki – pokrywy – korytka Trwalosc – odpornosc na zamrazanie/rozmrazanie w soli odladzajacej PN-EN 1433:2005 „N” | PN-EN 1433:2005/A1:2007 „N”","categories":["other"],"row_index":66,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Pavement drainage channels – gratings – covers – channels Durability – resistance to freezing/thawing in de-icing salt PN-EN 1433:2005 „N” | PN-EN 1433:2005/A1:2007 „N”","search_zh":"路面排水沟 － 格栅 － 盖板 － 沟槽 PN-EN 1433:2005 „N” | PN-EN 1433:2005/A1:2007 „N”","test_object_zh":"路面排水沟 － 格栅 － 盖板 － 沟槽"},{"_id":"6a5dc9b6f1c10c8ce825cc09","lab_id":"69ad52a3de79e566650fb2b6","country":"PL","accr_number":"AB 535","accr_body":"PCA","test_object":"Wyroby i systemy do ochrony i napraw konstrukcji betonowych","test_object_en":"Products and systems for the protection and repair of concrete structures","methodology":"Przyczepność","methodology_en":"Adhesion","parameters":[{"name":"Zakres","range":"(0,5 – 16) kN"}],"parameters_en":[{"name":"Range","range":"(0,5 – 16) kN"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Przyczepność\nZakres (0,5 – 16) kN","reference":"PN-EN 1542:2000","norm_bases":["PN-EN 1542:2000"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby i systemy do ochrony i napraw konstrukcji betonowych Przyczepność\nZakres (0,5 – 16) kN PN-EN 1542:2000 Wyroby i systemy do ochrony i napraw konstrukcji betonowych Przyczepnosc\nZakres (0,5 – 16) kN PN-EN 1542:2000","categories":["construction"],"row_index":67,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Products and systems for the protection and repair of concrete structures Adhesion Range PN-EN 1542:2000","parameters_zh":[{"name":"范围","range":"(0,5 – 16) kN"}],"search_zh":"混凝土结构防护与修复制品与系统 粘结强度 范围 PN-EN 1542:2000","methodology_zh":"粘结强度","test_object_zh":"混凝土结构防护与修复制品与系统"}],"has_pdf":true}