{"lab":{"_id":"69ad52a3de79e566650fb29f","accr_number":"AB 522","country":"PL","accr_body":"PCA","address":"Bożena i Waldemar Szleper, LABORATORIUM OCHRONY ŚRODOWISKA I WARUNKÓW PRACY, ul. Ikara 128b 42-221 Częstochowa","categories":["environment","water"],"city":"Częstochowa","imported_at":"2026-03-08T10:42:43.265Z","methods_count":118,"name":"ZAKŁAD USŁUG TECHNICZNYCH \"ZUT\" s.c.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_522.pdf"],"scope_summary":"","search_text":"zakład usług technicznych \"zut\" s.c. bożena i waldemar szleper, laboratorium ochrony środowiska i warunków pracy, ul. ikara 128b 42-221 częstochowa environment materials other petro metrology water food","status":"active","updated_at":"2026-03-08T14:51:23.440Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-20T00:32:12.446Z","location":{"type":"Point","coordinates":[19.1203,50.8118]},"email_confidence":"high","email_mx":true,"email_source":"http://www.zutsc.pl/kontakt/","fields_of_testing":[],"issue":{"no":"26","date":"18.08.2026"},"parse_date":"2026-08-20T00:32:12.446Z","parse_source":"agent-claude-code","map_coord":[50.84201,19.062007],"map_geo":"nominatim-street","has_en":true,"lab_locations":[{"name":"ZAKŁAD USŁUG TECHNICZNYCH \"ZUT\" s.c.","address":"ul. Ikara 128b 42-221 Częstochowa","city":"Częstochowa","postal":"42-221"},{"name":"LABORATORIUM OCHRONY ŚRODOWISKA I WARUNKÓW PRACY","address":"ul. Ikara 128b 42-221 Częstochowa","city":"Częstochowa","postal":"42-221"}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/19/41e152a784fcf96ffcf6e20d49e4f81b/AB%20522.pdf","category_counts":{"environment":97,"water":21,"materials":4,"construction":2,"automotive":2,"petro":1},"category_scores":{"environment":74.09,"water":3.47,"materials":0.13,"construction":0.03,"automotive":0.03,"petro":0.01},"has_zh":true},"methods":[{"_id":"6a864b0cfbf98dd0af9b1e0e","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Pobieranie próbek do oceny narażenia zawodowego na:","parameters":[{"name":"czynniki pyłowe – frakcja wdychalna – frakcja respirabilna"},{"name":"substancje organiczne, w tym – frakcja wdychalna"},{"name":"substancje nieorganiczne, w tym – frakcja wdychalna – frakcja respirabilna – frakcja torakalna"},{"name":"metale i ich związki, w tym – frakcja wdychalna – frakcja respirabilna"},{"name":"azbest – włókna respirabilne"}],"technique":"Metoda dozymetrii indywidualnej","techniques":["Metoda dozymetrii indywidualnej"],"computed":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe – frakcja wdychalna – frakcja respirabilna\nsubstancje organiczne, w tym – frakcja wdychalna\nsubstancje nieorganiczne, w tym – frakcja wdychalna – frakcja respirabilna – frakcja torakalna\nmetale i ich związki, w tym – frakcja wdychalna – frakcja respirabilna\nazbest – włókna respirabilne\nMetoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002+Az1:2004"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe – frakcja wdychalna – frakcja respirabilna\nsubstancje organiczne, w tym – frakcja wdychalna\nsubstancje nieorganiczne, w tym – frakcja wdychalna – frakcja respirabilna – frakcja torakalna\nmetale i ich związki, w tym – frakcja wdychalna – frakcja respirabilna\nazbest – włókna respirabilne\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy - powietrze Pobieranie probek do oceny narazenia zawodowego na:\nZakres:\nczynniki pylowe – frakcja wdychalna – frakcja respirabilna\nsubstancje organiczne, w tym – frakcja wdychalna\nsubstancje nieorganiczne, w tym – frakcja wdychalna – frakcja respirabilna – frakcja torakalna\nmetale i ich zwiazki, w tym – frakcja wdychalna – frakcja respirabilna\nazbest – wlokna respirabilne\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002+Az1:2004","categories":["materials","environment"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"职业接触评估采样，针对：","search_zh":"工作场所环境 — 空气 职业接触评估采样，针对： 个体剂量测定法 粉尘因素 — 可吸入组分 — 呼吸性组分 有机物质，包括 — 可吸入组分 无机物质，其中包括 － 可吸入性粉尘 － 呼吸性粉尘 － 胸腔性粉尘 金属及其化合物，包括 — 可吸入组分 — 呼吸性组分 石棉 — 呼吸性纤维 PN-Z-04008-7:2002+Az1:2004","technique_zh":"个体剂量测定法","test_object_zh":"工作场所环境 — 空气","parameters_zh":[{"name":"粉尘因素 — 可吸入组分 — 呼吸性组分"},{"name":"有机物质，包括 — 可吸入组分"},{"name":"无机物质，其中包括 － 可吸入性粉尘 － 呼吸性粉尘 － 胸腔性粉尘"},{"name":"金属及其化合物，包括 — 可吸入组分 — 呼吸性组分"},{"name":"石棉 — 呼吸性纤维"}]},{"_id":"6a864b0cfbf98dd0af9b1e0f","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Wskaźnik narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002+Az1:2004"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Wskaźnik narażenia (z obliczeń) PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy - powietrze Wskaznik narazenia (z obliczen) PN-Z-04008-7:2002+Az1:2004","categories":["environment"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"暴露指数（计算得出）","search_zh":"工作场所环境 — 空气 暴露指数（计算得出） PN-Z-04008-7:2002+Az1:2004","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a864b0cfbf98dd0af9b1e10","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna","parameters":[{"name":"cement portlandzki"},{"name":"ditlenek tytanu"},{"name":"grafit naturalny"},{"name":"grafit syntetyczny"},{"name":"kaolin"},{"name":"pyły drewna"},{"name":"pyły mąki"},{"name":"pyły niesklasyfikowane ze względu na toksyczność"},{"name":"pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"sadza techniczna"},{"name":"siarczan (VI) wapnia (gips)"},{"name":"talk"},{"name":"węgiel (kamienny, brunatny)"},{"name":"węglan magnezu wapnia (dolomit)"},{"name":"Zakres","range":"(0,14 – 20,42) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna\nZakres:\ncement portlandzki\nditlenek tytanu\ngrafit naturalny\ngrafit syntetyczny\nkaolin\npyły drewna\npyły mąki\npyły niesklasyfikowane ze względu na toksyczność\npyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nsadza techniczna\nsiarczan (VI) wapnia (gips)\ntalk\nwęgiel (kamienny, brunatny)\nwęglan magnezu wapnia (dolomit)\nZakres (0,14 – 20,42) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04507:2022-05 | PN-Z-04507:2022-05+Ap1:2022-08","norm_bases":["PN-Z-04507:2022-05","PN-Z-04507:2022-05+Ap1:2022-08"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna\nZakres:\ncement portlandzki\nditlenek tytanu\ngrafit naturalny\ngrafit syntetyczny\nkaolin\npyły drewna\npyły mąki\npyły niesklasyfikowane ze względu na toksyczność\npyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nsadza techniczna\nsiarczan (VI) wapnia (gips)\ntalk\nwęgiel (kamienny, brunatny)\nwęglan magnezu wapnia (dolomit)\nZakres (0,14 – 20,42) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05+Ap1:2022-08 Srodowisko pracy - powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia – frakcja wdychalna\nZakres:\ncement portlandzki\nditlenek tytanu\ngrafit naturalny\ngrafit syntetyczny\nkaolin\npyly drewna\npyly maki\npyly niesklasyfikowane ze wzgledu na toksycznosc\npyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nsadza techniczna\nsiarczan (VI) wapnia (gips)\ntalk\nwegiel (kamienny, brunatny)\nweglan magnezu wapnia (dolomit)\nZakres (0,14 – 20,42) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05+Ap1:2022-08","categories":["environment","construction"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"硅酸盐水泥"},{"name":"二氧化钛"},{"name":"天然石墨"},{"name":"合成石墨"},{"name":"高岭土"},{"name":"木粉尘"},{"name":"面粉粉尘"},{"name":"未按毒性分类的粉尘"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"炭黑"},{"name":"硫酸钙（VI）（石膏）"},{"name":"滑石"},{"name":"煤（烟煤、褐煤）"},{"name":"碳酸钙镁（白云石）"},{"name":"范围","range":"(0,14 – 20,42) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害粉尘因素浓度 — 可吸入组分 重量法 硅酸盐水泥 二氧化钛 天然石墨 合成石墨 高岭土 木粉尘 面粉粉尘 未按毒性分类的粉尘 动植物来源有机粉尘，木粉和面粉除外 炭黑 硫酸钙（VI）（石膏） 滑石 煤（烟煤、褐煤） 碳酸钙镁（白云石） 范围 PN-Z-04507:2022-05 | PN-Z-04507:2022-05+Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"有害粉尘因素浓度 — 可吸入组分"},{"_id":"6a864b0cfbf98dd0af9b1e11","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna","parameters":[{"name":"cement portlandzki"},{"name":"grafit naturalny"},{"name":"pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"talk"},{"name":"węgiel (kamienny, brunatny)"},{"name":"Zakres","range":"(0,11 – 37,88) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna\nZakres:\ncement portlandzki\ngrafit naturalny\npyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\ntalk\nwęgiel (kamienny, brunatny)\nZakres (0,11 – 37,88) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04508:2022-05 | PN-Z-04508:2022-05+Ap1:2022-08","norm_bases":["PN-Z-04508:2022-05","PN-Z-04508:2022-05+Ap1:2022-08"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna\nZakres:\ncement portlandzki\ngrafit naturalny\npyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\ntalk\nwęgiel (kamienny, brunatny)\nZakres (0,11 – 37,88) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05+Ap1:2022-08 Srodowisko pracy - powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia – frakcja respirabilna\nZakres:\ncement portlandzki\ngrafit naturalny\npyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\ntalk\nwegiel (kamienny, brunatny)\nZakres (0,11 – 37,88) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05+Ap1:2022-08","categories":["environment","construction"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"硅酸盐水泥"},{"name":"天然石墨"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"滑石"},{"name":"煤（烟煤、褐煤）"},{"name":"范围","range":"(0,11 – 37,88) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害粉尘因素浓度 — 呼吸性组分 重量法 硅酸盐水泥 天然石墨 动植物来源有机粉尘，木粉和面粉除外 滑石 煤（烟煤、褐煤） 范围 PN-Z-04508:2022-05 | PN-Z-04508:2022-05+Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"有害粉尘因素浓度 — 呼吸性组分"},{"_id":"6a864b0cfbf98dd0af9b1e12","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie tlenku azotu","parameters":[{"name":"Zakres","range":"(0,14 - 11,56) mg/m3"},{"name":"Zakres","range":"(0,112 – 9,3) ppm"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie tlenku azotu\nZakres:\nZakres (0,14 - 11,56) mg/m3\nZakres (0,112 – 9,3) ppm\nMetoda spektrofotometryczna","reference":"PN-Z-04009-11:2008","norm_bases":["PN-Z-04009-11:2008"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie tlenku azotu\nZakres:\nZakres (0,14 - 11,56) mg/m3\nZakres (0,112 – 9,3) ppm\nMetoda spektrofotometryczna PN-Z-04009-11:2008 Srodowisko pracy - powietrze Stezenie tlenku azotu\nZakres:\nZakres (0,14 - 11,56) mg/m3\nZakres (0,112 – 9,3) ppm\nMetoda spektrofotometryczna PN-Z-04009-11:2008","categories":["environment"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,14 - 11,56) mg/m3"},{"name":"范围","range":"(0,112 – 9,3) ppm"}],"search_zh":"工作场所环境 — 空气 一氧化氮浓度 分光光度法 范围 范围 PN-Z-04009-11:2008","technique_zh":"分光光度法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"一氧化氮浓度"},{"_id":"6a864b0cfbf98dd0af9b1e13","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie ditlenku azotu","parameters":[{"name":"Zakres","range":"(0,04 - 3,55) mg/m3"},{"name":"Zakres","range":"(0,021 – 1,9) ppm"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie ditlenku azotu\nZakres:\nZakres (0,04 - 3,55) mg/m3\nZakres (0,021 – 1,9) ppm\nMetoda spektrofotometryczna","reference":"PN-Z-04009-11:2008","norm_bases":["PN-Z-04009-11:2008"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie ditlenku azotu\nZakres:\nZakres (0,04 - 3,55) mg/m3\nZakres (0,021 – 1,9) ppm\nMetoda spektrofotometryczna PN-Z-04009-11:2008 Srodowisko pracy - powietrze Stezenie ditlenku azotu\nZakres:\nZakres (0,04 - 3,55) mg/m3\nZakres (0,021 – 1,9) ppm\nMetoda spektrofotometryczna PN-Z-04009-11:2008","categories":["environment"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,04 - 3,55) mg/m3"},{"name":"范围","range":"(0,021 – 1,9) ppm"}],"search_zh":"工作场所环境 — 空气 二氧化氮浓度 分光光度法 范围 范围 PN-Z-04009-11:2008","technique_zh":"分光光度法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"二氧化氮浓度"},{"_id":"6a864b0cfbf98dd0af9b1e14","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie tlenku węgla","parameters":[{"name":"Zakres","range":"(2,32 – 139,2) mg/m3"},{"name":"Zakres","range":"(2 – 120) ppm"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Stężenie tlenku węgla\nZakres:\nZakres (2,32 – 139,2) mg/m3\nZakres (2 – 120) ppm\nMetoda elektrochemiczna","reference":"PB-17-02 wydanie 6 z dnia 25.04.2025 r.","norm_bases":["PB-17-02 wydanie 6 z dnia 25.04.2025 r."],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie tlenku węgla\nZakres:\nZakres (2,32 – 139,2) mg/m3\nZakres (2 – 120) ppm\nMetoda elektrochemiczna PB-17-02 wydanie 6 z dnia 25.04.2025 r. Srodowisko pracy - powietrze Stezenie tlenku wegla\nZakres:\nZakres (2,32 – 139,2) mg/m3\nZakres (2 – 120) ppm\nMetoda elektrochemiczna PB-17-02 wydanie 6 z dnia 25.04.2025 r.","categories":["environment"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(2,32 – 139,2) mg/m3"},{"name":"范围","range":"(2 – 120) ppm"}],"search_zh":"工作场所环境 — 空气 一氧化碳浓度 电化学法 范围 范围 PB-17-02 wydanie 6 z dnia 25.04.2025 r.","technique_zh":"电化学法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"一氧化碳浓度"},{"_id":"6a864b0cfbf98dd0af9b1e15","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Wskaźniki narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźniki narażenia (z obliczeń)","reference":"PB-17-02 wydanie 6 z dnia 25.04.2025 r.","norm_bases":["PB-17-02 wydanie 6 z dnia 25.04.2025 r."],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Wskaźniki narażenia (z obliczeń) PB-17-02 wydanie 6 z dnia 25.04.2025 r. Srodowisko pracy - powietrze Wskazniki narazenia (z obliczen) PB-17-02 wydanie 6 z dnia 25.04.2025 r.","categories":["environment"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","search_zh":"工作场所环境 — 空气 暴露指数（计算值） PB-17-02 wydanie 6 z dnia 25.04.2025 r.","test_object_zh":"工作场所环境 — 空气","methodology_zh":"暴露指数（计算值）"},{"_id":"6a864b0cfbf98dd0af9b1e16","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie miedzi i jej związków nieorganicznych w przeliczeniu na Cu","parameters":[{"name":"Zakres","range":"(0,003 - 6,9) mg/m3"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie miedzi i jej związków nieorganicznych w przeliczeniu na Cu\nZakres (0,003 - 6,9) mg/m3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-79/Z-04106.02","norm_bases":["PN-79/Z-04106.02"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie miedzi i jej związków nieorganicznych w przeliczeniu na Cu\nZakres (0,003 - 6,9) mg/m3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-79/Z-04106.02 Srodowisko pracy - powietrze Stezenie miedzi i jej zwiazkow nieorganicznych w przeliczeniu na Cu\nZakres (0,003 - 6,9) mg/m3\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-79/Z-04106.02","categories":["environment"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,003 - 6,9) mg/m3"}],"search_zh":"工作场所环境 — 空气 铜及其无机化合物浓度（以 Cu 计） 火焰原子吸收光谱法（FAAS） 范围 PN-79/Z-04106.02","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 — 空气","methodology_zh":"铜及其无机化合物浓度（以 Cu 计）"},{"_id":"6a864b0cfbf98dd0af9b1e17","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie manganu i jego związków nieorganicznych w przeliczeniu na Mn – frakcja wdychalna","parameters":[{"name":"Zakres","range":"(0,002 - 2,1) mg/m3"},{"name":"– frakcja respirabilna"},{"name":"Zakres","range":"(0,002 - 2,1) mg/m3"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie manganu i jego związków nieorganicznych w przeliczeniu na Mn – frakcja wdychalna\nZakres:\nZakres (0,002 - 2,1) mg/m3\n– frakcja respirabilna\nZakres (0,002 - 2,1) mg/m3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04472:2015-10","norm_bases":["PN-Z-04472:2015-10"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie manganu i jego związków nieorganicznych w przeliczeniu na Mn – frakcja wdychalna\nZakres:\nZakres (0,002 - 2,1) mg/m3\n– frakcja respirabilna\nZakres (0,002 - 2,1) mg/m3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04472:2015-10 Srodowisko pracy - powietrze Stezenie manganu i jego zwiazkow nieorganicznych w przeliczeniu na Mn – frakcja wdychalna\nZakres:\nZakres (0,002 - 2,1) mg/m3\n– frakcja respirabilna\nZakres (0,002 - 2,1) mg/m3\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04472:2015-10","categories":["environment"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,002 - 2,1) mg/m3"},{"name":"— 呼吸性组分"},{"name":"范围","range":"(0,002 - 2,1) mg/m3"}],"search_zh":"工作场所环境 — 空气 锰及其无机化合物浓度（以 Mn 计）－ 可吸入性粉尘 火焰原子吸收光谱法（FAAS） 范围 — 呼吸性组分 范围 PN-Z-04472:2015-10","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 — 空气","methodology_zh":"锰及其无机化合物浓度（以 Mn 计）－ 可吸入性粉尘"},{"_id":"6a864b0cfbf98dd0af9b1e18","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie tlenku cynku w przeliczeniu na Zn – frakcja wdychalna","parameters":[{"name":"Zakres","range":"(0,001 - 16,7) mg/m3"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie tlenku cynku w przeliczeniu na Zn – frakcja wdychalna\nZakres (0,001 - 16,7) mg/m3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-87/Z-04100.03","norm_bases":["PN-87/Z-04100.03"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie tlenku cynku w przeliczeniu na Zn – frakcja wdychalna\nZakres (0,001 - 16,7) mg/m3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-87/Z-04100.03 Srodowisko pracy - powietrze Stezenie tlenku cynku w przeliczeniu na Zn – frakcja wdychalna\nZakres (0,001 - 16,7) mg/m3\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-87/Z-04100.03","categories":["environment"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,001 - 16,7) mg/m3"}],"search_zh":"工作场所环境 — 空气 火焰原子吸收光谱法（FAAS） 范围 PN-87/Z-04100.03","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a864b0cfbf98dd0af9b1e19","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie tlenków żelaza w przeliczeniu na Fe – frakcja wdychalna","parameters":[{"name":"Zakres","range":"(0,003 – 10,7) mg/m3"},{"name":"– frakcja respirabilna"},{"name":"Zakres","range":"(0,003 – 9,7) mg/m3"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie tlenków żelaza w przeliczeniu na Fe – frakcja wdychalna\nZakres:\nZakres (0,003 – 10,7) mg/m3\n– frakcja respirabilna\nZakres (0,003 – 9,7) mg/m3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04469:2025-02","norm_bases":["PN-Z-04469:2025-02"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie tlenków żelaza w przeliczeniu na Fe – frakcja wdychalna\nZakres:\nZakres (0,003 – 10,7) mg/m3\n– frakcja respirabilna\nZakres (0,003 – 9,7) mg/m3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04469:2025-02 Srodowisko pracy - powietrze Stezenie tlenkow zelaza w przeliczeniu na Fe – frakcja wdychalna\nZakres:\nZakres (0,003 – 10,7) mg/m3\n– frakcja respirabilna\nZakres (0,003 – 9,7) mg/m3\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04469:2025-02","categories":["environment"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,003 – 10,7) mg/m3"},{"name":"— 呼吸性组分"},{"name":"范围","range":"(0,003 – 9,7) mg/m3"}],"search_zh":"工作场所环境 — 空气 火焰原子吸收光谱法（FAAS） 范围 — 呼吸性组分 范围 PN-Z-04469:2025-02","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a864b0cfbf98dd0af9b1e1a","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie ołowiu i jego związków nieorganicznych w przeliczeniu na Pb","parameters":[{"name":"Zakres","range":"(0,0035 – 1,39) mg/m3"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie ołowiu i jego związków nieorganicznych w przeliczeniu na Pb\nZakres (0,0035 – 1,39) mg/m3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z 04487:2017-10","norm_bases":["PN-Z 04487:2017-10"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie ołowiu i jego związków nieorganicznych w przeliczeniu na Pb\nZakres (0,0035 – 1,39) mg/m3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z 04487:2017-10 Srodowisko pracy - powietrze Stezenie olowiu i jego zwiazkow nieorganicznych w przeliczeniu na Pb\nZakres (0,0035 – 1,39) mg/m3\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z 04487:2017-10","categories":["environment"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,0035 – 1,39) mg/m3"}],"search_zh":"工作场所环境 — 空气 铅及其无机化合物浓度（以 Pb 计） 火焰原子吸收光谱法（FAAS） 范围 PN-Z 04487:2017-10","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 — 空气","methodology_zh":"铅及其无机化合物浓度（以 Pb 计）"},{"_id":"6a864b0cfbf98dd0af9b1e1b","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie wodorotlenku sodowego","parameters":[{"name":"Zakres","range":"(0,006 - 2,0) mg/m3"}],"technique":"Metoda emisyjnej spektrometrii płomieniowej","techniques":["Metoda emisyjnej spektrometrii płomieniowej"],"computed":[],"activity":"Stężenie wodorotlenku sodowego\nZakres (0,006 - 2,0) mg/m3\nMetoda emisyjnej spektrometrii płomieniowej","reference":"PN-Z-04435:2011","norm_bases":["PN-Z-04435:2011"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie wodorotlenku sodowego\nZakres (0,006 - 2,0) mg/m3\nMetoda emisyjnej spektrometrii płomieniowej PN-Z-04435:2011 Srodowisko pracy - powietrze Stezenie wodorotlenku sodowego\nZakres (0,006 - 2,0) mg/m3\nMetoda emisyjnej spektrometrii plomieniowej PN-Z-04435:2011","categories":["environment"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,006 - 2,0) mg/m3"}],"search_zh":"工作场所环境 — 空气 火焰发射光谱法 范围 PN-Z-04435:2011","test_object_zh":"工作场所环境 — 空气","technique_zh":"火焰发射光谱法"},{"_id":"6a864b0cfbf98dd0af9b1e1c","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie wodorotlenku potasowego","parameters":[{"name":"Zakres","range":"(0,005 - 2,4) mg/m3"}],"technique":"Metoda emisyjnej spektrometrii płomieniowej","techniques":["Metoda emisyjnej spektrometrii płomieniowej"],"computed":[],"activity":"Stężenie wodorotlenku potasowego\nZakres (0,005 - 2,4) mg/m3\nMetoda emisyjnej spektrometrii płomieniowej","reference":"PN-Z-04436:2011","norm_bases":["PN-Z-04436:2011"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie wodorotlenku potasowego\nZakres (0,005 - 2,4) mg/m3\nMetoda emisyjnej spektrometrii płomieniowej PN-Z-04436:2011 Srodowisko pracy - powietrze Stezenie wodorotlenku potasowego\nZakres (0,005 - 2,4) mg/m3\nMetoda emisyjnej spektrometrii plomieniowej PN-Z-04436:2011","categories":["environment"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,005 - 2,4) mg/m3"}],"search_zh":"工作场所环境 — 空气 火焰发射光谱法 范围 PN-Z-04436:2011","test_object_zh":"工作场所环境 — 空气","technique_zh":"火焰发射光谱法"},{"_id":"6a864b0cfbf98dd0af9b1e1d","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie etylobenzenu","parameters":[{"name":"Zakres","range":"(0,21 – 1041,72) mg/m3"},{"name":"Stężenie kumenu"},{"name":"Zakres","range":"(0,52 – 1028,11) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie etylobenzenu\nZakres:\nZakres (0,21 – 1041,72) mg/m3\nStężenie kumenu\nZakres (0,52 – 1028,11) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PB-17-27 wydanie 7 z dnia 20.06.2022 r. *","norm_bases":["PB-17-27 wydanie 7 z dnia 20.06.2022 r. *"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie etylobenzenu\nZakres:\nZakres (0,21 – 1041,72) mg/m3\nStężenie kumenu\nZakres (0,52 – 1028,11) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PB-17-27 wydanie 7 z dnia 20.06.2022 r. * Srodowisko pracy - powietrze Stezenie etylobenzenu\nZakres:\nZakres (0,21 – 1041,72) mg/m3\nStezenie kumenu\nZakres (0,52 – 1028,11) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PB-17-27 wydanie 7 z dnia 20.06.2022 r. *","categories":["environment"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,21 – 1041,72) mg/m3"},{"name":"Stężenie kumenu"},{"name":"范围","range":"(0,52 – 1028,11) mg/m3"}],"search_zh":"工作场所环境 — 空气 乙苯浓度 气相色谱-火焰离子化检测法（GC-FID） 范围 范围 PB-17-27 wydanie 7 z dnia 20.06.2022 r. *","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气","methodology_zh":"乙苯浓度"},{"_id":"6a864b0cfbf98dd0af9b1e1e","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Szkodliwe substancje wydzielające się z wyrobów lakierowych nitrocelulozowych:","parameters":[{"name":"aceton"},{"name":"Zakres","range":"(0,53 – 2677,22) mg/m3"},{"name":"butan-1-ol"},{"name":"Zakres","range":"(0,50 – 997,77) mg/m3"},{"name":"2-metylo-1-propanol"},{"name":"Zakres","range":"(0,50 – 985,28) mg/m3"},{"name":"toluen"},{"name":"Zakres","range":"(0,21–1083,17) mg/m3"},{"name":"ksylen – mieszanina izomerów 1,2; 1,3; 1,4"},{"name":"Zakres","range":"(0,21–1073,33) mg/m3"},{"name":"octan etylu"},{"name":"Zakres","range":"(0,42 – 2086,77) mg/m3"},{"name":"Zakres","range":"(0,115 – 570,8) ppm"},{"name":"octan butylu"},{"name":"Zakres","range":"(0,54 - 1083) mg/m3"},{"name":"etanol"},{"name":"Zakres","range":"(2,28 – 4553,56) mg/m3"},{"name":"2-butoksyetanol"},{"name":"Zakres","range":"(0,22–1089,83) mg/m3"},{"name":"2-etoksyetanol"},{"name":"Zakres","range":"(0,22 – 1141,11) mg/m3"},{"name":"Zakres","range":"(0,059 – 305,2) ppm"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo - jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo - jonizacyjną (GC-FID)"],"computed":[],"activity":"Szkodliwe substancje wydzielające się z wyrobów lakierowych nitrocelulozowych:\nZakres:\naceton\nZakres (0,53 – 2677,22) mg/m3\nbutan-1-ol\nZakres (0,50 – 997,77) mg/m3\n2-metylo-1-propanol\nZakres (0,50 – 985,28) mg/m3\ntoluen\nZakres (0,21–1083,17) mg/m3\nksylen – mieszanina izomerów 1,2; 1,3; 1,4\nZakres (0,21–1073,33) mg/m3\noctan etylu\nZakres (0,42 – 2086,77) mg/m3\nZakres (0,115 – 570,8) ppm\noctan butylu\nZakres (0,54 - 1083) mg/m3\netanol\nZakres (2,28 – 4553,56) mg/m3\n2-butoksyetanol\nZakres (0,22–1089,83) mg/m3\n2-etoksyetanol\nZakres (0,22 – 1141,11) mg/m3\nZakres (0,059 – 305,2) ppm\nMetoda chromatografii gazowej z detekcją płomieniowo - jonizacyjną (GC-FID)","reference":"PN-89/Z-04023-02 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. *","norm_bases":["PN-89/Z-04023-02","PB-17-27 wydanie 7 z dnia 20.06.2022 r. *"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Szkodliwe substancje wydzielające się z wyrobów lakierowych nitrocelulozowych:\nZakres:\naceton\nZakres (0,53 – 2677,22) mg/m3\nbutan-1-ol\nZakres (0,50 – 997,77) mg/m3\n2-metylo-1-propanol\nZakres (0,50 – 985,28) mg/m3\ntoluen\nZakres (0,21–1083,17) mg/m3\nksylen – mieszanina izomerów 1,2; 1,3; 1,4\nZakres (0,21–1073,33) mg/m3\noctan etylu\nZakres (0,42 – 2086,77) mg/m3\nZakres (0,115 – 570,8) ppm\noctan butylu\nZakres (0,54 - 1083) mg/m3\netanol\nZakres (2,28 – 4553,56) mg/m3\n2-butoksyetanol\nZakres (0,22–1089,83) mg/m3\n2-etoksyetanol\nZakres (0,22 – 1141,11) mg/m3\nZakres (0,059 – 305,2) ppm\nMetoda chromatografii gazowej z detekcją płomieniowo - jonizacyjną (GC-FID) PN-89/Z-04023-02 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. * Srodowisko pracy - powietrze Szkodliwe substancje wydzielajace sie z wyrobow lakierowych nitrocelulozowych:\nZakres:\naceton\nZakres (0,53 – 2677,22) mg/m3\nbutan-1-ol\nZakres (0,50 – 997,77) mg/m3\n2-metylo-1-propanol\nZakres (0,50 – 985,28) mg/m3\ntoluen\nZakres (0,21–1083,17) mg/m3\nksylen – mieszanina izomerow 1,2; 1,3; 1,4\nZakres (0,21–1073,33) mg/m3\noctan etylu\nZakres (0,42 – 2086,77) mg/m3\nZakres (0,115 – 570,8) ppm\noctan butylu\nZakres (0,54 - 1083) mg/m3\netanol\nZakres (2,28 – 4553,56) mg/m3\n2-butoksyetanol\nZakres (0,22–1089,83) mg/m3\n2-etoksyetanol\nZakres (0,22 – 1141,11) mg/m3\nZakres (0,059 – 305,2) ppm\nMetoda chromatografii gazowej z detekcja plomieniowo - jonizacyjna (GC-FID) PN-89/Z-04023-02 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. *","categories":["environment","automotive"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"丙酮"},{"name":"范围","range":"(0,53 – 2677,22) mg/m3"},{"name":"正丁醇"},{"name":"范围","range":"(0,50 – 997,77) mg/m3"},{"name":"2-metylo-1-propanol"},{"name":"范围","range":"(0,50 – 985,28) mg/m3"},{"name":"甲苯"},{"name":"范围","range":"(0,21–1083,17) mg/m3"},{"name":"ksylen – mieszanina izomerów 1,2; 1,3; 1,4"},{"name":"范围","range":"(0,21–1073,33) mg/m3"},{"name":"乙酸乙酯"},{"name":"范围","range":"(0,42 – 2086,77) mg/m3"},{"name":"范围","range":"(0,115 – 570,8) ppm"},{"name":"乙酸丁酯"},{"name":"范围","range":"(0,54 - 1083) mg/m3"},{"name":"乙醇"},{"name":"范围","range":"(2,28 – 4553,56) mg/m3"},{"name":"2-丁氧基乙醇"},{"name":"范围","range":"(0,22–1089,83) mg/m3"},{"name":"2-乙氧基乙醇"},{"name":"范围","range":"(0,22 – 1141,11) mg/m3"},{"name":"范围","range":"(0,059 – 305,2) ppm"}],"search_zh":"工作场所环境 — 空气 气相色谱-火焰离子化检测法（GC-FID） 丙酮 范围 正丁醇 范围 范围 甲苯 范围 范围 乙酸乙酯 范围 范围 乙酸丁酯 范围 乙醇 范围 2-丁氧基乙醇 范围 2-乙氧基乙醇 范围 范围 PN-89/Z-04023-02 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. *","test_object_zh":"工作场所环境 — 空气","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）"},{"_id":"6a864b0cfbf98dd0af9b1e1f","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie octanu metylu","parameters":[{"name":"Zakres","range":"(0,22-1114,22) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo - jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo - jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie octanu metylu\nZakres (0,22-1114,22) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo - jonizacyjną (GC-FID)","reference":"PN-78/Z-04119.01 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. *","norm_bases":["PN-78/Z-04119.01","PB-17-27 wydanie 7 z dnia 20.06.2022 r. *"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie octanu metylu\nZakres (0,22-1114,22) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo - jonizacyjną (GC-FID) PN-78/Z-04119.01 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. * Srodowisko pracy - powietrze Stezenie octanu metylu\nZakres (0,22-1114,22) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo - jonizacyjna (GC-FID) PN-78/Z-04119.01 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. *","categories":["environment"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,22-1114,22) mg/m3"}],"search_zh":"工作场所环境 — 空气 气相色谱-火焰离子化检测法（GC-FID） 范围 PN-78/Z-04119.01 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. *","test_object_zh":"工作场所环境 — 空气","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）"},{"_id":"6a864b0cfbf98dd0af9b1e20","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie butan-2-onu","parameters":[{"name":"Zakres","range":"(0,28-1425,61) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo - jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo - jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie butan-2-onu\nZakres (0,28-1425,61) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo - jonizacyjną (GC-FID)","reference":"PB-17-27 wydanie 7 z dnia 20.06.2022 r. *","norm_bases":["PB-17-27 wydanie 7 z dnia 20.06.2022 r. *"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie butan-2-onu\nZakres (0,28-1425,61) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo - jonizacyjną (GC-FID) PB-17-27 wydanie 7 z dnia 20.06.2022 r. * Srodowisko pracy - powietrze Stezenie butan-2-onu\nZakres (0,28-1425,61) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo - jonizacyjna (GC-FID) PB-17-27 wydanie 7 z dnia 20.06.2022 r. *","categories":["environment"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,28-1425,61) mg/m3"}],"search_zh":"工作场所环境 — 空气 气相色谱-火焰离子化检测法（GC-FID） 范围 PB-17-27 wydanie 7 z dnia 20.06.2022 r. *","test_object_zh":"工作场所环境 — 空气","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）"},{"_id":"6a864b0cfbf98dd0af9b1e21","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie styrenu","parameters":[{"name":"Zakres","range":"(0,55-1100,44) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie styrenu\nZakres (0,55-1100,44) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PN-86/Z-04152.02 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. *","norm_bases":["PN-86/Z-04152.02","PB-17-27 wydanie 7 z dnia 20.06.2022 r. *"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie styrenu\nZakres (0,55-1100,44) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PN-86/Z-04152.02 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. * Srodowisko pracy - powietrze Stezenie styrenu\nZakres (0,55-1100,44) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PN-86/Z-04152.02 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. *","categories":["environment"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,55-1100,44) mg/m3"}],"search_zh":"工作场所环境 — 空气 苯乙烯浓度 气相色谱-火焰离子化检测法（GC-FID） 范围 PN-86/Z-04152.02 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. *","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气","methodology_zh":"苯乙烯浓度"},{"_id":"6a864b0cfbf98dd0af9b1e22","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie tetrachloroetenu","parameters":[{"name":"Zakres","range":"(0,94-1909,94) mg/m3"},{"name":"Zakres","range":"(0,136 – 277,6) ppm"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie tetrachloroetenu\nZakres:\nZakres (0,94-1909,94) mg/m3\nZakres (0,136 – 277,6) ppm\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PN-Z-04325:2006 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. *","norm_bases":["PN-Z-04325:2006","PB-17-27 wydanie 7 z dnia 20.06.2022 r. *"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie tetrachloroetenu\nZakres:\nZakres (0,94-1909,94) mg/m3\nZakres (0,136 – 277,6) ppm\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PN-Z-04325:2006 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. * Srodowisko pracy - powietrze Stezenie tetrachloroetenu\nZakres:\nZakres (0,94-1909,94) mg/m3\nZakres (0,136 – 277,6) ppm\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PN-Z-04325:2006 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. *","categories":["environment"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,94-1909,94) mg/m3"},{"name":"范围","range":"(0,136 – 277,6) ppm"}],"search_zh":"工作场所环境 — 空气 四氯乙烯浓度 气相色谱-火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04325:2006 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. *","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气","methodology_zh":"四氯乙烯浓度"},{"_id":"6a864b0cfbf98dd0af9b1e23","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie trichloroetenu","parameters":[{"name":"Zakres","range":"(0,83-1714,94) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie trichloroetenu\nZakres (0,83-1714,94) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PN-Z-04325:2006 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. *","norm_bases":["PN-Z-04325:2006","PB-17-27 wydanie 7 z dnia 20.06.2022 r. *"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie trichloroetenu\nZakres (0,83-1714,94) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PN-Z-04325:2006 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. * Srodowisko pracy - powietrze Stezenie trichloroetenu\nZakres (0,83-1714,94) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PN-Z-04325:2006 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. *","categories":["environment"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,83-1714,94) mg/m3"}],"search_zh":"工作场所环境 — 空气 三氯乙烯浓度 气相色谱-火焰离子化检测法（GC-FID） 范围 PN-Z-04325:2006 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. *","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气","methodology_zh":"三氯乙烯浓度"},{"_id":"6a864b0cfbf98dd0af9b1e24","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie 4-metylopentan-2-onu","parameters":[{"name":"Zakres","range":"(0,20-983,83) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie 4-metylopentan-2-onu\nZakres (0,20-983,83) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2001, 4 (30) | PB-17-27 wydanie 7 z dnia 20.06.2022 r. *","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2001, 4 (30)","PB-17-27 wydanie 7 z dnia 20.06.2022 r. *"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie 4-metylopentan-2-onu\nZakres (0,20-983,83) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) Podstawy i Metody Oceny Środowiska Pracy 2001, 4 (30) | PB-17-27 wydanie 7 z dnia 20.06.2022 r. * Srodowisko pracy - powietrze Stezenie 4-metylopentan-2-onu\nZakres (0,20-983,83) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) Podstawy i Metody Oceny Srodowiska Pracy 2001, 4 (30) | PB-17-27 wydanie 7 z dnia 20.06.2022 r. *","categories":["environment"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,20-983,83) mg/m3"}],"search_zh":"工作场所环境 — 空气 气相色谱-火焰离子化检测法（GC-FID） 范围 Podstawy i Metody Oceny Środowiska Pracy 2001, 4 (30) | PB-17-27 wydanie 7 z dnia 20.06.2022 r. *","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a864b0cfbf98dd0af9b1e25","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie 3-metylobutan-1-olu","parameters":[{"name":"Zakres","range":"(0,50-997,56) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie 3-metylobutan-1-olu\nZakres (0,50-997,56) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PN-Z-04355:2005 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. *","norm_bases":["PN-Z-04355:2005","PB-17-27 wydanie 7 z dnia 20.06.2022 r. *"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie 3-metylobutan-1-olu\nZakres (0,50-997,56) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PN-Z-04355:2005 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. * Srodowisko pracy - powietrze Stezenie 3-metylobutan-1-olu\nZakres (0,50-997,56) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PN-Z-04355:2005 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. *","categories":["environment"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,50-997,56) mg/m3"}],"search_zh":"工作场所环境 — 空气 气相色谱-火焰离子化检测法（GC-FID） 范围 PN-Z-04355:2005 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. *","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a864b0cfbf98dd0af9b1e26","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie acetonitrylu","parameters":[{"name":"Zakres","range":"(0,46-925,33) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie acetonitrylu\nZakres (0,46-925,33) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PN-Z-04244-02:2006 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. *","norm_bases":["PN-Z-04244-02:2006","PB-17-27 wydanie 7 z dnia 20.06.2022 r. *"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie acetonitrylu\nZakres (0,46-925,33) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PN-Z-04244-02:2006 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. * Srodowisko pracy - powietrze Stezenie acetonitrylu\nZakres (0,46-925,33) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PN-Z-04244-02:2006 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. *","categories":["environment"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,46-925,33) mg/m3"}],"search_zh":"工作场所环境 — 空气 气相色谱-火焰离子化检测法（GC-FID） 范围 PN-Z-04244-02:2006 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. *","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a864b0cfbf98dd0af9b1e27","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie propan-2-olu","parameters":[{"name":"Zakres","range":"(1,33-2693,00) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie propan-2-olu\nZakres (1,33-2693,00) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PN-92/Z-04224.02 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. *","norm_bases":["PN-92/Z-04224.02","PB-17-27 wydanie 7 z dnia 20.06.2022 r. *"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie propan-2-olu\nZakres (1,33-2693,00) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PN-92/Z-04224.02 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. * Srodowisko pracy - powietrze Stezenie propan-2-olu\nZakres (1,33-2693,00) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PN-92/Z-04224.02 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. *","categories":["environment"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(1,33-2693,00) mg/m3"}],"search_zh":"工作场所环境 — 空气 异丙醇浓度 气相色谱-火焰离子化检测法（GC-FID） 范围 PN-92/Z-04224.02 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. *","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气","methodology_zh":"异丙醇浓度"},{"_id":"6a864b0cfbf98dd0af9b1e28","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie octanu winylu","parameters":[{"name":"Zakres","range":"(0,56-1127,61) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie octanu winylu\nZakres (0,56-1127,61) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PN-87/Z-04178.02 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. *","norm_bases":["PN-87/Z-04178.02","PB-17-27 wydanie 7 z dnia 20.06.2022 r. *"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie octanu winylu\nZakres (0,56-1127,61) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PN-87/Z-04178.02 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. * Srodowisko pracy - powietrze Stezenie octanu winylu\nZakres (0,56-1127,61) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PN-87/Z-04178.02 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. *","categories":["environment"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,56-1127,61) mg/m3"}],"search_zh":"工作场所环境 — 空气 乙酸乙烯酯浓度 气相色谱-火焰离子化检测法（GC-FID） 范围 PN-87/Z-04178.02 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. *","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气","methodology_zh":"乙酸乙烯酯浓度"},{"_id":"6a864b0cfbf98dd0af9b1e29","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie nafty","parameters":[{"name":"Zakres","range":"(0,94-947,44) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie nafty\nZakres (0,94-947,44) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PN-92/Z-04227.02 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. *","norm_bases":["PN-92/Z-04227.02","PB-17-27 wydanie 7 z dnia 20.06.2022 r. *"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie nafty\nZakres (0,94-947,44) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PN-92/Z-04227.02 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. * Srodowisko pracy - powietrze Stezenie nafty\nZakres (0,94-947,44) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PN-92/Z-04227.02 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. *","categories":["environment"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,94-947,44) mg/m3"}],"search_zh":"工作场所环境 — 空气 煤油浓度 气相色谱-火焰离子化检测法（GC-FID） 范围 PN-92/Z-04227.02 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. *","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气","methodology_zh":"煤油浓度"},{"_id":"6a864b0cfbf98dd0af9b1e2a","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie pentanu","parameters":[{"name":"Zakres","range":"(2,11-4203,44) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie pentanu\nZakres (2,11-4203,44) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PB-17-27 wydanie 7 z dnia 20.06.2022 r. *","norm_bases":["PB-17-27 wydanie 7 z dnia 20.06.2022 r. *"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie pentanu\nZakres (2,11-4203,44) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PB-17-27 wydanie 7 z dnia 20.06.2022 r. * Srodowisko pracy - powietrze Stezenie pentanu\nZakres (2,11-4203,44) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PB-17-27 wydanie 7 z dnia 20.06.2022 r. *","categories":["environment"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(2,11-4203,44) mg/m3"}],"search_zh":"工作场所环境 — 空气 戊烷浓度 气相色谱-火焰离子化检测法（GC-FID） 范围 PB-17-27 wydanie 7 z dnia 20.06.2022 r. *","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气","methodology_zh":"戊烷浓度"},{"_id":"6a864b0cfbf98dd0af9b1e2b","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie heksanu","parameters":[{"name":"Zakres","range":"(0,41-805,78) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie heksanu\nZakres (0,41-805,78) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2011, 1 (67) | PB-17-27 wydanie 7 z dnia 20.06.2022 r. *","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2011, 1 (67)","PB-17-27 wydanie 7 z dnia 20.06.2022 r. *"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie heksanu\nZakres (0,41-805,78) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) Podstawy i Metody Oceny Środowiska Pracy 2011, 1 (67) | PB-17-27 wydanie 7 z dnia 20.06.2022 r. * Srodowisko pracy - powietrze Stezenie heksanu\nZakres (0,41-805,78) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) Podstawy i Metody Oceny Srodowiska Pracy 2011, 1 (67) | PB-17-27 wydanie 7 z dnia 20.06.2022 r. *","categories":["environment"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,41-805,78) mg/m3"}],"search_zh":"工作场所环境 — 空气 正己烷浓度 气相色谱-火焰离子化检测法（GC-FID） 范围 Podstawy i Metody Oceny Środowiska Pracy 2011, 1 (67) | PB-17-27 wydanie 7 z dnia 20.06.2022 r. *","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气","methodology_zh":"正己烷浓度"},{"_id":"6a864b0cfbf98dd0af9b1e2c","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie heptanu","parameters":[{"name":"Zakres","range":"(1,55-3107,83) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie heptanu\nZakres (1,55-3107,83) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2004, 4 (42) | PB-17-27 wydanie 7 z dnia 20.06.2022 r. *","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2004, 4 (42)","PB-17-27 wydanie 7 z dnia 20.06.2022 r. *"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie heptanu\nZakres (1,55-3107,83) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) Podstawy i Metody Oceny Środowiska Pracy 2004, 4 (42) | PB-17-27 wydanie 7 z dnia 20.06.2022 r. * Srodowisko pracy - powietrze Stezenie heptanu\nZakres (1,55-3107,83) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) Podstawy i Metody Oceny Srodowiska Pracy 2004, 4 (42) | PB-17-27 wydanie 7 z dnia 20.06.2022 r. *","categories":["environment"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(1,55-3107,83) mg/m3"}],"search_zh":"工作场所环境 — 空气 正庚烷浓度 气相色谱-火焰离子化检测法（GC-FID） 范围 Podstawy i Metody Oceny Środowiska Pracy 2004, 4 (42) | PB-17-27 wydanie 7 z dnia 20.06.2022 r. *","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气","methodology_zh":"正庚烷浓度"},{"_id":"6a864b0cfbf98dd0af9b1e2d","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie metylocykloheksanu","parameters":[{"name":"Zakres","range":"(2,16-4311,67) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie metylocykloheksanu\nZakres (2,16-4311,67) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2011, 1 (67) | PB-17-27 wydanie 7 z dnia 20.06.2022 r. *","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2011, 1 (67)","PB-17-27 wydanie 7 z dnia 20.06.2022 r. *"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie metylocykloheksanu\nZakres (2,16-4311,67) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) Podstawy i Metody Oceny Środowiska Pracy 2011, 1 (67) | PB-17-27 wydanie 7 z dnia 20.06.2022 r. * Srodowisko pracy - powietrze Stezenie metylocykloheksanu\nZakres (2,16-4311,67) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) Podstawy i Metody Oceny Srodowiska Pracy 2011, 1 (67) | PB-17-27 wydanie 7 z dnia 20.06.2022 r. *","categories":["environment"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(2,16-4311,67) mg/m3"}],"search_zh":"工作场所环境 — 空气 气相色谱-火焰离子化检测法（GC-FID） 范围 Podstawy i Metody Oceny Środowiska Pracy 2011, 1 (67) | PB-17-27 wydanie 7 z dnia 20.06.2022 r. *","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a864b0cfbf98dd0af9b1e2e","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie trimetylobenzenu – mieszaniny izomerów 1,2,3;1,2,4;1,3,5","parameters":[{"name":"Zakres","range":"(0,52-1091,83) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie trimetylobenzenu – mieszaniny izomerów 1,2,3;1,2,4;1,3,5\nZakres (0,52-1091,83) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PN-Z-04016-4:1998 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. *","norm_bases":["PN-Z-04016-4:1998","PB-17-27 wydanie 7 z dnia 20.06.2022 r. *"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie trimetylobenzenu – mieszaniny izomerów 1,2,3;1,2,4;1,3,5\nZakres (0,52-1091,83) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PN-Z-04016-4:1998 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. * Srodowisko pracy - powietrze Stezenie trimetylobenzenu – mieszaniny izomerow 1,2,3;1,2,4;1,3,5\nZakres (0,52-1091,83) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PN-Z-04016-4:1998 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. *","categories":["environment"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,52-1091,83) mg/m3"}],"search_zh":"工作场所环境 — 空气 气相色谱-火焰离子化检测法（GC-FID） 范围 PN-Z-04016-4:1998 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. *","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a864b0cfbf98dd0af9b1e2f","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie 2-furylometanolu","parameters":[{"name":"Zakres","range":"(0,67-1365,06) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie 2-furylometanolu\nZakres (0,67-1365,06) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PN-90/Z-04214.02 | PB-17-21 wydanie 7 z dnia 20.06.2022 r. *","norm_bases":["PN-90/Z-04214.02","PB-17-21 wydanie 7 z dnia 20.06.2022 r. *"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie 2-furylometanolu\nZakres (0,67-1365,06) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PN-90/Z-04214.02 | PB-17-21 wydanie 7 z dnia 20.06.2022 r. * Srodowisko pracy - powietrze Stezenie 2-furylometanolu\nZakres (0,67-1365,06) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PN-90/Z-04214.02 | PB-17-21 wydanie 7 z dnia 20.06.2022 r. *","categories":["environment"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,67-1365,06) mg/m3"}],"search_zh":"工作场所环境 — 空气 气相色谱-火焰离子化检测法（GC-FID） 范围 PN-90/Z-04214.02 | PB-17-21 wydanie 7 z dnia 20.06.2022 r. *","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a864b0cfbf98dd0af9b1e30","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie kwasu octowego","parameters":[{"name":"Zakres","range":"(0,56-1172,78) mg/m3"},{"name":"Zakres","range":"(0,225 – 470,7) ppm"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie kwasu octowego\nZakres:\nZakres (0,56-1172,78) mg/m3\nZakres (0,225 – 470,7) ppm\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PN-Z-04323:2004 | PB-17-21 wydanie 7 z dnia 20.06.2022 r. *","norm_bases":["PN-Z-04323:2004","PB-17-21 wydanie 7 z dnia 20.06.2022 r. *"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie kwasu octowego\nZakres:\nZakres (0,56-1172,78) mg/m3\nZakres (0,225 – 470,7) ppm\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PN-Z-04323:2004 | PB-17-21 wydanie 7 z dnia 20.06.2022 r. * Srodowisko pracy - powietrze Stezenie kwasu octowego\nZakres:\nZakres (0,56-1172,78) mg/m3\nZakres (0,225 – 470,7) ppm\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PN-Z-04323:2004 | PB-17-21 wydanie 7 z dnia 20.06.2022 r. *","categories":["environment"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,56-1172,78) mg/m3"},{"name":"范围","range":"(0,225 – 470,7) ppm"}],"search_zh":"工作场所环境 — 空气 气相色谱-火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04323:2004 | PB-17-21 wydanie 7 z dnia 20.06.2022 r. *","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a864b0cfbf98dd0af9b1e31","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie fenolu","parameters":[{"name":"Zakres","range":"(0,083-83,33) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie fenolu\nZakres (0,083-83,33) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"Podstawy i Metody Oceny Środowiska Pracy 1999, nr 22 | PB-17-21 wydanie 7 z dnia 20.06.2022 r. *","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 1999, nr 22","PB-17-21 wydanie 7 z dnia 20.06.2022 r. *"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie fenolu\nZakres (0,083-83,33) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) Podstawy i Metody Oceny Środowiska Pracy 1999, nr 22 | PB-17-21 wydanie 7 z dnia 20.06.2022 r. * Srodowisko pracy - powietrze Stezenie fenolu\nZakres (0,083-83,33) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) Podstawy i Metody Oceny Srodowiska Pracy 1999, nr 22 | PB-17-21 wydanie 7 z dnia 20.06.2022 r. *","categories":["environment"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,083-83,33) mg/m3"}],"search_zh":"工作场所环境 — 空气 苯酚浓度 气相色谱-火焰离子化检测法（GC-FID） 范围 Podstawy i Metody Oceny Środowiska Pracy 1999, nr 22 | PB-17-21 wydanie 7 z dnia 20.06.2022 r. *","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气","methodology_zh":"苯酚浓度"},{"_id":"6a864b0cfbf98dd0af9b1e32","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie naftalenu","parameters":[{"name":"Zakres","range":"(2,61-68,89) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie naftalenu\nZakres (2,61-68,89) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PN-Z-04098-3:2005 | PB-17-21 wydanie 7 z dnia 20.06.2022 r. *","norm_bases":["PN-Z-04098-3:2005","PB-17-21 wydanie 7 z dnia 20.06.2022 r. *"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie naftalenu\nZakres (2,61-68,89) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PN-Z-04098-3:2005 | PB-17-21 wydanie 7 z dnia 20.06.2022 r. * Srodowisko pracy - powietrze Stezenie naftalenu\nZakres (2,61-68,89) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PN-Z-04098-3:2005 | PB-17-21 wydanie 7 z dnia 20.06.2022 r. *","categories":["environment"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(2,61-68,89) mg/m3"}],"search_zh":"工作场所环境 — 空气 气相色谱-火焰离子化检测法（GC-FID） 范围 PN-Z-04098-3:2005 | PB-17-21 wydanie 7 z dnia 20.06.2022 r. *","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a864b0cfbf98dd0af9b1e33","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie krezolu – mieszanina izomerów","parameters":[{"name":"Zakres","range":"(0,08-83,33) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie krezolu – mieszanina izomerów\nZakres (0,08-83,33) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"Podstawy i Metody Oceny Środowiska Pracy 1999, nr 22 | PB-17-21 wydanie 7 z dnia 20.06.2022 r. *","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 1999, nr 22","PB-17-21 wydanie 7 z dnia 20.06.2022 r. *"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie krezolu – mieszanina izomerów\nZakres (0,08-83,33) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) Podstawy i Metody Oceny Środowiska Pracy 1999, nr 22 | PB-17-21 wydanie 7 z dnia 20.06.2022 r. * Srodowisko pracy - powietrze Stezenie krezolu – mieszanina izomerow\nZakres (0,08-83,33) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) Podstawy i Metody Oceny Srodowiska Pracy 1999, nr 22 | PB-17-21 wydanie 7 z dnia 20.06.2022 r. *","categories":["environment"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,08-83,33) mg/m3"}],"search_zh":"工作场所环境 — 空气 气相色谱-火焰离子化检测法（GC-FID） 范围 Podstawy i Metody Oceny Środowiska Pracy 1999, nr 22 | PB-17-21 wydanie 7 z dnia 20.06.2022 r. *","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a864b0cfbf98dd0af9b1e34","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie cykloheksanu","parameters":[{"name":"Zakres","range":"(0,33-1802,61) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie cykloheksanu\nZakres (0,33-1802,61) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2011, 1 (67) | PB-17-27 wydanie 7 z dnia 20.06.2022 r. *","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2011, 1 (67)","PB-17-27 wydanie 7 z dnia 20.06.2022 r. *"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie cykloheksanu\nZakres (0,33-1802,61) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) Podstawy i Metody Oceny Środowiska Pracy 2011, 1 (67) | PB-17-27 wydanie 7 z dnia 20.06.2022 r. * Srodowisko pracy - powietrze Stezenie cykloheksanu\nZakres (0,33-1802,61) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) Podstawy i Metody Oceny Srodowiska Pracy 2011, 1 (67) | PB-17-27 wydanie 7 z dnia 20.06.2022 r. *","categories":["environment"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,33-1802,61) mg/m3"}],"search_zh":"工作场所环境 — 空气 气相色谱-火焰离子化检测法（GC-FID） 范围 Podstawy i Metody Oceny Środowiska Pracy 2011, 1 (67) | PB-17-27 wydanie 7 z dnia 20.06.2022 r. *","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a864b0cfbf98dd0af9b1e35","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie propan-1-olu","parameters":[{"name":"Zakres","range":"(0,72-1439,22) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie propan-1-olu\nZakres (0,72-1439,22) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PN-Z-04224-3:2003 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. *","norm_bases":["PN-Z-04224-3:2003","PB-17-27 wydanie 7 z dnia 20.06.2022 r. *"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie propan-1-olu\nZakres (0,72-1439,22) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PN-Z-04224-3:2003 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. * Srodowisko pracy - powietrze Stezenie propan-1-olu\nZakres (0,72-1439,22) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PN-Z-04224-3:2003 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. *","categories":["environment"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,72-1439,22) mg/m3"}],"search_zh":"工作场所环境 — 空气 气相色谱-火焰离子化检测法（GC-FID） 范围 PN-Z-04224-3:2003 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. *","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a864b0cfbf98dd0af9b1e36","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie elektryczne we wnętrzach","methodology":"Natężenie oświetlenia","parameters":[{"name":"Zakres","range":"(0,5 - 9500) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie oświetlenia\nZakres (0,5 - 9500) lx\nMetoda pomiarowa bezpośrednia","reference":"PN-83/E-04040.03 | PB-17-03 wydanie 5 z dnia 21.05.2025 r.","norm_bases":["PN-83/E-04040.03","PB-17-03 wydanie 5 z dnia 21.05.2025 r."],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie elektryczne we wnętrzach Natężenie oświetlenia\nZakres (0,5 - 9500) lx\nMetoda pomiarowa bezpośrednia PN-83/E-04040.03 | PB-17-03 wydanie 5 z dnia 21.05.2025 r. Srodowisko pracy - oswietlenie elektryczne we wnetrzach Natezenie oswietlenia\nZakres (0,5 - 9500) lx\nMetoda pomiarowa bezposrednia PN-83/E-04040.03 | PB-17-03 wydanie 5 z dnia 21.05.2025 r.","categories":["environment"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"照度","parameters_zh":[{"name":"范围","range":"(0,5 - 9500) lx"}],"search_zh":"工作场所环境 — 室内电气照明 照度 直接测量法 范围 PN-83/E-04040.03 | PB-17-03 wydanie 5 z dnia 21.05.2025 r.","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 室内电气照明"},{"_id":"6a864b0cfbf98dd0af9b1e37","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie elektryczne we wnętrzach","methodology":"Równomierność oświetlenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równomierność oświetlenia (z obliczeń)","reference":"PN-83/E-04040.03 | PB-17-03 wydanie 5 z dnia 21.05.2025 r.","norm_bases":["PN-83/E-04040.03","PB-17-03 wydanie 5 z dnia 21.05.2025 r."],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie elektryczne we wnętrzach Równomierność oświetlenia (z obliczeń) PN-83/E-04040.03 | PB-17-03 wydanie 5 z dnia 21.05.2025 r. Srodowisko pracy - oswietlenie elektryczne we wnetrzach Rownomiernosc oswietlenia (z obliczen) PN-83/E-04040.03 | PB-17-03 wydanie 5 z dnia 21.05.2025 r.","categories":["environment"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"照度均匀度（计算值）","search_zh":"工作场所环境 — 室内电气照明 照度均匀度（计算值） PN-83/E-04040.03 | PB-17-03 wydanie 5 z dnia 21.05.2025 r.","test_object_zh":"工作场所环境 — 室内电气照明"},{"_id":"6a864b0cfbf98dd0af9b1e38","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie awaryjne","methodology":"Natężenie oświetlenia","parameters":[{"name":"Zakres","range":"(0,5 - 200) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie oświetlenia\nZakres (0,5 - 200) lx\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 1838:2013-11 z wyłączeniem p. 4.2.3; 4.2.4; 4.2.5; 4.2.6; 4.3.3; 4.3.4; 4.3.5; 4.3.6; 4.4.3; 4.4.4; 4.4.5; 4.4.6; 5","norm_bases":["PN-EN 1838:2013-11 z wyłączeniem p. 4.2.3; 4.2.4; 4.2.5; 4.2.6; 4.3.3; 4.3.4; 4.3.5; 4.3.6; 4.4.3; 4.4.4; 4.4.5; 4.4.6; 5"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie awaryjne Natężenie oświetlenia\nZakres (0,5 - 200) lx\nMetoda pomiarowa bezpośrednia PN-EN 1838:2013-11 z wyłączeniem p. 4.2.3; 4.2.4; 4.2.5; 4.2.6; 4.3.3; 4.3.4; 4.3.5; 4.3.6; 4.4.3; 4.4.4; 4.4.5; 4.4.6; 5 Srodowisko pracy - oswietlenie awaryjne Natezenie oswietlenia\nZakres (0,5 - 200) lx\nMetoda pomiarowa bezposrednia PN-EN 1838:2013-11 z wylaczeniem p. 4.2.3; 4.2.4; 4.2.5; 4.2.6; 4.3.3; 4.3.4; 4.3.5; 4.3.6; 4.4.3; 4.4.4; 4.4.5; 4.4.6; 5","categories":["environment"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"照度","parameters_zh":[{"name":"范围","range":"(0,5 - 200) lx"}],"search_zh":"工作场所环境 — 应急照明 照度 直接测量法 范围 PN-EN 1838:2013-11 z wyłączeniem p. 4.2.3; 4.2.4; 4.2.5; 4.2.6; 4.3.3; 4.3.4; 4.3.5; 4.3.6; 4.4.3; 4.4.4; 4.4.5; 4.4.6; 5","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 应急照明"},{"_id":"6a864b0cfbf98dd0af9b1e39","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie awaryjne","methodology":"Stosunek minimalnego do maksymalnego natężenia oświetlenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stosunek minimalnego do maksymalnego natężenia oświetlenia (z obliczeń)","reference":"PN-EN 1838:2013-11 z wyłączeniem p. 4.2.3; 4.2.4; 4.2.5; 4.2.6; 4.3.3; 4.3.4; 4.3.5; 4.3.6; 4.4.3; 4.4.4; 4.4.5; 4.4.6; 5","norm_bases":["PN-EN 1838:2013-11 z wyłączeniem p. 4.2.3; 4.2.4; 4.2.5; 4.2.6; 4.3.3; 4.3.4; 4.3.5; 4.3.6; 4.4.3; 4.4.4; 4.4.5; 4.4.6; 5"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie awaryjne Stosunek minimalnego do maksymalnego natężenia oświetlenia (z obliczeń) PN-EN 1838:2013-11 z wyłączeniem p. 4.2.3; 4.2.4; 4.2.5; 4.2.6; 4.3.3; 4.3.4; 4.3.5; 4.3.6; 4.4.3; 4.4.4; 4.4.5; 4.4.6; 5 Srodowisko pracy - oswietlenie awaryjne Stosunek minimalnego do maksymalnego natezenia oswietlenia (z obliczen) PN-EN 1838:2013-11 z wylaczeniem p. 4.2.3; 4.2.4; 4.2.5; 4.2.6; 4.3.3; 4.3.4; 4.3.5; 4.3.6; 4.4.3; 4.4.4; 4.4.5; 4.4.6; 5","categories":["environment"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"最小与最大照度之比（计算值）","search_zh":"工作场所环境 — 应急照明 最小与最大照度之比（计算值） PN-EN 1838:2013-11 z wyłączeniem p. 4.2.3; 4.2.4; 4.2.5; 4.2.6; 4.3.3; 4.3.4; 4.3.5; 4.3.6; 4.4.3; 4.4.4; 4.4.5; 4.4.6; 5","test_object_zh":"工作场所环境 — 应急照明"},{"_id":"6a864b0cfbf98dd0af9b1e3a","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie awaryjne","methodology":"Równomierność oświetlenia dla strefy wysokiego ryzyka (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równomierność oświetlenia dla strefy wysokiego ryzyka (z obliczeń)","reference":"PN-EN 1838:2013-11 z wyłączeniem p. 4.2.3; 4.2.4; 4.2.5; 4.2.6; 4.3.3; 4.3.4; 4.3.5; 4.3.6; 4.4.3; 4.4.4; 4.4.5; 4.4.6; 5","norm_bases":["PN-EN 1838:2013-11 z wyłączeniem p. 4.2.3; 4.2.4; 4.2.5; 4.2.6; 4.3.3; 4.3.4; 4.3.5; 4.3.6; 4.4.3; 4.4.4; 4.4.5; 4.4.6; 5"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie awaryjne Równomierność oświetlenia dla strefy wysokiego ryzyka (z obliczeń) PN-EN 1838:2013-11 z wyłączeniem p. 4.2.3; 4.2.4; 4.2.5; 4.2.6; 4.3.3; 4.3.4; 4.3.5; 4.3.6; 4.4.3; 4.4.4; 4.4.5; 4.4.6; 5 Srodowisko pracy - oswietlenie awaryjne Rownomiernosc oswietlenia dla strefy wysokiego ryzyka (z obliczen) PN-EN 1838:2013-11 z wylaczeniem p. 4.2.3; 4.2.4; 4.2.5; 4.2.6; 4.3.3; 4.3.4; 4.3.5; 4.3.6; 4.4.3; 4.4.4; 4.4.5; 4.4.6; 5","categories":["environment"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","search_zh":"工作场所环境 — 应急照明 高风险区照度均匀度（计算值） PN-EN 1838:2013-11 z wyłączeniem p. 4.2.3; 4.2.4; 4.2.5; 4.2.6; 4.3.3; 4.3.4; 4.3.5; 4.3.6; 4.4.3; 4.4.4; 4.4.5; 4.4.6; 5","test_object_zh":"工作场所环境 — 应急照明","methodology_zh":"高风险区照度均匀度（计算值）"},{"_id":"6a864b0cfbf98dd0af9b1e3b","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - hałas","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(25 – 136) dB"},{"name":"Szczytowy poziom dźwięku C"},{"name":"Zakres","range":"(69 - 136) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (25 – 136) dB\nSzczytowy poziom dźwięku C\nZakres (69 - 136) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię nr 2 – punkt 10 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię nr 2 i 3 – punkt 10 i 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię nr 2 – punkt 10","PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię nr 2 i 3 – punkt 10 i 11"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (25 – 136) dB\nSzczytowy poziom dźwięku C\nZakres (69 - 136) dB\nMetoda pomiarowa bezpośrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię nr 2 – punkt 10 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię nr 2 i 3 – punkt 10 i 11 Srodowisko pracy - halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A\nZakres:\nZakres (25 – 136) dB\nSzczytowy poziom dzwieku C\nZakres (69 - 136) dB\nMetoda pomiarowa bezposrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie nr 2 – punkt 10 | PN-EN ISO 9612:2025-11 z wylaczeniem metody obejmujacej strategie nr 2 i 3 – punkt 10 i 11","categories":["environment"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"A 计权等效声级 A 计权最大声级","parameters_zh":[{"name":"范围","range":"(25 – 136) dB"},{"name":"C 计权峰值声级"},{"name":"范围","range":"(69 - 136) dB"}],"search_zh":"工作场所环境 — 噪声 A 计权等效声级 A 计权最大声级 直接测量法 范围 C 计权峰值声级 范围 PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię nr 2 – punkt 10 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię nr 2 i 3 – punkt 10 i 11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a864b0cfbf98dd0af9b1e3c","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - hałas","methodology":"Poziom ekspozycji na hałas odniesiony do:","parameters":[{"name":"8-godz. dobowego wymiaru czasu pracy"},{"name":"przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię nr 2 – punkt 10 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię nr 2 i 3 – punkt 10 i 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię nr 2 – punkt 10","PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię nr 2 i 3 – punkt 10 i 11"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - hałas Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię nr 2 – punkt 10 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię nr 2 i 3 – punkt 10 i 11 Srodowisko pracy - halas Poziom ekspozycji na halas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzecietnego tygodniowego wymiaru czasu pracy (z obliczen) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie nr 2 – punkt 10 | PN-EN ISO 9612:2025-11 z wylaczeniem metody obejmujacej strategie nr 2 i 3 – punkt 10 i 11","categories":["environment"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"噪声暴露级，参照：","parameters_zh":[{"name":"8 小时日工作时间"},{"name":"平均每周工作时间（计算值）"}],"search_zh":"工作场所环境 — 噪声 噪声暴露级，参照： 8 小时日工作时间 平均每周工作时间（计算值） PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię nr 2 – punkt 10 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię nr 2 i 3 – punkt 10 i 11","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a864b0cfbf98dd0af9b1e3d","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(23 - 136) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A\nZakres (23 - 136) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F | PN-ISO 1996-2:1999+A1:2002","norm_bases":["Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F","PN-ISO 1996-2:1999+A1:2002"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A\nZakres (23 - 136) dB\nMetoda pomiarowa bezpośrednia Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F | PN-ISO 1996-2:1999+A1:2002 Srodowisko ogolne – halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A\nZakres (23 - 136) dB\nMetoda pomiarowa bezposrednia Zalacznik nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wylaczeniem punktu F | PN-ISO 1996-2:1999+A1:2002","categories":["environment"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"范围","range":"(23 - 136) dB"}],"search_zh":"一般环境 – 来自设施、设备与工业企业的噪声 A 计权等效声级 直接测量法 范围 Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F | PN-ISO 1996-2:1999+A1:2002","technique_zh":"直接测量法","test_object_zh":"一般环境 – 来自设施、设备与工业企业的噪声"},{"_id":"6a864b0cfbf98dd0af9b1e3e","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F | PN-ISO 1996-2:1999+A1:2002","norm_bases":["Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F","PN-ISO 1996-2:1999+A1:2002"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F | PN-ISO 1996-2:1999+A1:2002 Srodowisko ogolne – halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen) Zalacznik nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wylaczeniem punktu F | PN-ISO 1996-2:1999+A1:2002","categories":["environment"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境 – 来自设施、设备与工业企业的噪声 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值） Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F | PN-ISO 1996-2:1999+A1:2002","test_object_zh":"一般环境 – 来自设施、设备与工业企业的噪声"},{"_id":"6a864b0cfbf98dd0af9b1e3f","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej - hałas","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(23 - 136) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres (23 - 136) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-87/B-02156","norm_bases":["PN-87/B-02156"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej - hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres (23 - 136) dB\nMetoda pomiarowa bezpośrednia PN-87/B-02156 Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i uzytecznosci publicznej - halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A\nZakres (23 - 136) dB\nMetoda pomiarowa bezposrednia PN-87/B-02156","categories":["environment"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"A 计权等效声级 A 计权最大声级","parameters_zh":[{"name":"范围","range":"(23 - 136) dB"}],"search_zh":"住宅、集体居住与公共建筑内的房间 — 噪声 A 计权等效声级 A 计权最大声级 直接测量法 范围 PN-87/B-02156","technique_zh":"直接测量法","test_object_zh":"住宅、集体居住与公共建筑内的房间 — 噪声"},{"_id":"6a864b0cfbf98dd0af9b1e40","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej - hałas","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T (z obliczeń)","reference":"PN-87/B-02156","norm_bases":["PN-87/B-02156"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej - hałas Równoważny poziom dźwięku A dla czasu odniesienia T (z obliczeń) PN-87/B-02156 Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i uzytecznosci publicznej - halas Rownowazny poziom dzwieku A dla czasu odniesienia T (z obliczen) PN-87/B-02156","categories":["environment"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"参考时间 T 内的 A 计权等效声级（计算得出）","search_zh":"住宅、集体居住与公共建筑内的房间 — 噪声 参考时间 T 内的 A 计权等效声级（计算得出） PN-87/B-02156","test_object_zh":"住宅、集体居住与公共建筑内的房间 — 噪声"},{"_id":"6a864b0cfbf98dd0af9b1e41","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","parameters":[{"name":"Zakres","range":"(0,06 – 100 ) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,06 – 100 ) m/s2\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-2:2004/A1:2015-11"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,06 – 100 ) m/s2\nMetoda pomiarowa bezpośrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 Srodowisko pracy – drgania dzialajace na organizm czlowieka przez konczyny gorne Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres (0,06 – 100 ) m/s2\nMetoda pomiarowa bezposrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","categories":["environment"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"频率计权振动加速度有效值","parameters_zh":[{"name":"范围","range":"(0,06 – 100 ) m/s2"}],"search_zh":"工作场所环境 — 手传振动 频率计权振动加速度有效值 直接测量法 范围 PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 手传振动"},{"_id":"6a864b0cfbf98dd0af9b1e42","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8 godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszenia drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszenia drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8 godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszenia drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszenia drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-2:2004/A1:2015-11"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8 godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszenia drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszenia drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 Srodowisko pracy – drgania dzialajace na organizm czlowieka przez konczyny gorne Ekspozycja dzienna, wyrazona w postaci rownowaznego energetycznie dla 8 godzin dzialania sumy wektorowej skutecznych, skorygowanych czestotliwosciowo przyspieszenia drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci sumy wektorowej skutecznych, wazonych czestotliwosciowo przyspieszenia drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz) (z obliczen) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","categories":["environment"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code","search_zh":"工作场所环境 — 手传振动 PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","test_object_zh":"工作场所环境 — 手传振动"},{"_id":"6a864b0cfbf98dd0af9b1e43","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - drgania o działaniu ogólnym na organizm człowieka","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","parameters":[{"name":"Zakres","range":"(0,01 – 35) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,01 – 35) m/s2\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 14253+ A1:2011","norm_bases":["PN-EN 14253+ A1:2011"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - drgania o działaniu ogólnym na organizm człowieka Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,01 – 35) m/s2\nMetoda pomiarowa bezpośrednia PN-EN 14253+ A1:2011 Srodowisko pracy - drgania o dzialaniu ogolnym na organizm czlowieka Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres (0,01 – 35) m/s2\nMetoda pomiarowa bezposrednia PN-EN 14253+ A1:2011","categories":["environment"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"频率计权振动加速度有效值","parameters_zh":[{"name":"范围","range":"(0,01 – 35) m/s2"}],"search_zh":"工作环境 － 对人体产生全身作用的振动 频率计权振动加速度有效值 直接测量法 范围 PN-EN 14253+ A1:2011","technique_zh":"直接测量法","test_object_zh":"工作环境 － 对人体产生全身作用的振动"},{"_id":"6a864b0cfbf98dd0af9b1e44","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - drgania o działaniu ogólnym na organizm człowieka","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8 godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem współczynników (1,4awx, 1,4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem współczynników (1,4awx, 1,4awy, awz) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8 godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem współczynników (1,4awx, 1,4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem współczynników (1,4awx, 1,4awy, awz) (z obliczeń)","reference":"PN-EN 14253+ A1:2011","norm_bases":["PN-EN 14253+ A1:2011"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - drgania o działaniu ogólnym na organizm człowieka Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8 godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem współczynników (1,4awx, 1,4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem współczynników (1,4awx, 1,4awy, awz) (z obliczeń) PN-EN 14253+ A1:2011 Srodowisko pracy - drgania o dzialaniu ogolnym na organizm czlowieka Ekspozycja dzienna, wyrazona w postaci rownowaznego energetycznie dla 8 godzin dzialania skutecznego, skorygowanego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wspolczynnikow (1,4awx, 1,4awy, awz), Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci skutecznego, wazonego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wspolczynnikow (1,4awx, 1,4awy, awz) (z obliczen) PN-EN 14253+ A1:2011","categories":["environment"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code","search_zh":"工作环境 － 对人体产生全身作用的振动 PN-EN 14253+ A1:2011","test_object_zh":"工作环境 － 对人体产生全身作用的振动"},{"_id":"6a864b0cfbf98dd0af9b1e45","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat umiarkowany","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(5 – 50) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(5 – 50) °C"},{"name":"Wilgotność powietrza"},{"name":"Zakres","range":"(20 – 80) %"},{"name":"Prędkość powietrza"},{"name":"Zakres","range":"(0,16 – 3,0) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (5 – 50) °C\nTemperatura poczernionej kuli\nZakres (5 – 50) °C\nWilgotność powietrza\nZakres (20 – 80) %\nPrędkość powietrza\nZakres (0,16 – 3,0) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","norm_bases":["PN-EN ISO 7730:2006","PN-EN ISO 7730:2006/Ap2:2016-04"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat umiarkowany Temperatura powietrza\nZakres:\nZakres (5 – 50) °C\nTemperatura poczernionej kuli\nZakres (5 – 50) °C\nWilgotność powietrza\nZakres (20 – 80) %\nPrędkość powietrza\nZakres (0,16 – 3,0) m/s\nMetoda pomiarowa bezpośrednia PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04 Srodowisko pracy - mikroklimat umiarkowany Temperatura powietrza\nZakres:\nZakres (5 – 50) °C\nTemperatura poczernionej kuli\nZakres (5 – 50) °C\nWilgotnosc powietrza\nZakres (20 – 80) %\nPredkosc powietrza\nZakres (0,16 – 3,0) m/s\nMetoda pomiarowa bezposrednia PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","categories":["environment"],"row_index":55,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(5 – 50) °C"},{"name":"黑球温度"},{"name":"范围","range":"(5 – 50) °C"},{"name":"空气湿度"},{"name":"范围","range":"(20 – 80) %"},{"name":"空气流速"},{"name":"范围","range":"(0,16 – 3,0) m/s"}],"search_zh":"工作场所环境 — 中等微气候 空气温度 直接测量法 范围 黑球温度 范围 空气湿度 范围 空气流速 范围 PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 中等微气候"},{"_id":"6a864b0cfbf98dd0af9b1e46","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat umiarkowany","methodology":"Wskaźnik PMV, Wskaźnik PPD (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik PMV, Wskaźnik PPD (z obliczeń)","reference":"PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","norm_bases":["PN-EN ISO 7730:2006","PN-EN ISO 7730:2006/Ap2:2016-04"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat umiarkowany Wskaźnik PMV, Wskaźnik PPD (z obliczeń) PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04 Srodowisko pracy - mikroklimat umiarkowany Wskaznik PMV, Wskaznik PPD (z obliczen) PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","categories":["environment"],"row_index":56,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"PMV 指数、PPD 指数（计算值）","search_zh":"工作场所环境 — 中等微气候 PMV 指数、PPD 指数（计算值） PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","test_object_zh":"工作场所环境 — 中等微气候"},{"_id":"6a864b0cfbf98dd0af9b1e47","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat gorący","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(20 – 60) °C"},{"name":"Temperatura wilgotna naturalna"},{"name":"Zakres","range":"(20 – 50) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(20 – 60) °C"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (20 – 60) °C\nTemperatura wilgotna naturalna\nZakres (20 – 50) °C\nTemperatura poczernionej kuli\nZakres (20 – 60) °C\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7243:2018-01","norm_bases":["PN-EN ISO 7243:2018-01"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat gorący Temperatura powietrza\nZakres:\nZakres (20 – 60) °C\nTemperatura wilgotna naturalna\nZakres (20 – 50) °C\nTemperatura poczernionej kuli\nZakres (20 – 60) °C\nMetoda pomiarowa bezpośrednia PN-EN ISO 7243:2018-01 Srodowisko pracy - mikroklimat goracy Temperatura powietrza\nZakres:\nZakres (20 – 60) °C\nTemperatura wilgotna naturalna\nZakres (20 – 50) °C\nTemperatura poczernionej kuli\nZakres (20 – 60) °C\nMetoda pomiarowa bezposrednia PN-EN ISO 7243:2018-01","categories":["environment"],"row_index":57,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(20 – 60) °C"},{"name":"自然湿球温度"},{"name":"范围","range":"(20 – 50) °C"},{"name":"黑球温度"},{"name":"范围","range":"(20 – 60) °C"}],"search_zh":"工作场所环境 — 高温微气候 空气温度 直接测量法 范围 自然湿球温度 范围 黑球温度 范围 PN-EN ISO 7243:2018-01","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 高温微气候"},{"_id":"6a864b0cfbf98dd0af9b1e48","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat gorący","methodology":"Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń)","reference":"PN-EN ISO 7243:2018-01","norm_bases":["PN-EN ISO 7243:2018-01"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat gorący Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń) PN-EN ISO 7243:2018-01 Srodowisko pracy - mikroklimat goracy Wskaznik WBGT, Wskaznik WBGTeff (z obliczen) PN-EN ISO 7243:2018-01","categories":["environment"],"row_index":58,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"WBGT 指数、WBGTeff 指数（计算值）","search_zh":"工作场所环境 — 高温微气候 WBGT 指数、WBGTeff 指数（计算值） PN-EN ISO 7243:2018-01","test_object_zh":"工作场所环境 — 高温微气候"},{"_id":"6a864b0cfbf98dd0af9b1e49","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat zimny","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(-30 – 20) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(-30 – 20) °C"},{"name":"Wilgotność powietrza"},{"name":"Zakres","range":"(20 – 80) %"},{"name":"Prędkość powietrza"},{"name":"Zakres","range":"(0,16 – 3,0) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (-30 – 20) °C\nTemperatura poczernionej kuli\nZakres (-30 – 20) °C\nWilgotność powietrza\nZakres (20 – 80) %\nPrędkość powietrza\nZakres (0,16 – 3,0) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 11079:2008","norm_bases":["PN-EN ISO 11079:2008"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat zimny Temperatura powietrza\nZakres:\nZakres (-30 – 20) °C\nTemperatura poczernionej kuli\nZakres (-30 – 20) °C\nWilgotność powietrza\nZakres (20 – 80) %\nPrędkość powietrza\nZakres (0,16 – 3,0) m/s\nMetoda pomiarowa bezpośrednia PN-EN ISO 11079:2008 Srodowisko pracy - mikroklimat zimny Temperatura powietrza\nZakres:\nZakres (-30 – 20) °C\nTemperatura poczernionej kuli\nZakres (-30 – 20) °C\nWilgotnosc powietrza\nZakres (20 – 80) %\nPredkosc powietrza\nZakres (0,16 – 3,0) m/s\nMetoda pomiarowa bezposrednia PN-EN ISO 11079:2008","categories":["environment"],"row_index":59,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(-30 – 20) °C"},{"name":"黑球温度"},{"name":"范围","range":"(-30 – 20) °C"},{"name":"空气湿度"},{"name":"范围","range":"(20 – 80) %"},{"name":"空气流速"},{"name":"范围","range":"(0,16 – 3,0) m/s"}],"search_zh":"工作场所环境 — 低温微气候 空气温度 直接测量法 范围 黑球温度 范围 空气湿度 范围 空气流速 范围 PN-EN ISO 11079:2008","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 低温微气候"},{"_id":"6a864b0cfbf98dd0af9b1e4a","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat zimny","methodology":"Wskaźnik IREQmin, Wskaźnik IREQneutral, Wskaźnik twc (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik IREQmin, Wskaźnik IREQneutral, Wskaźnik twc (z obliczeń)","reference":"PN-EN ISO 11079:2008","norm_bases":["PN-EN ISO 11079:2008"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat zimny Wskaźnik IREQmin, Wskaźnik IREQneutral, Wskaźnik twc (z obliczeń) PN-EN ISO 11079:2008 Srodowisko pracy - mikroklimat zimny Wskaznik IREQmin, Wskaznik IREQneutral, Wskaznik twc (z obliczen) PN-EN ISO 11079:2008","categories":["environment"],"row_index":60,"parse_version":4,"parse_source":"agent-claude-code","search_zh":"工作场所环境 — 低温微气候 IREQmin 指数、IREQneutral 指数、twc 指数（计算值） PN-EN ISO 11079:2008","test_object_zh":"工作场所环境 — 低温微气候","methodology_zh":"IREQmin 指数、IREQneutral 指数、twc 指数（计算值）"},{"_id":"6a864b0cfbf98dd0af9b1e4b","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - wydatek energetyczny","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(5 - 35) oC"},{"name":"Przepływ powietrza"},{"name":"Zakres","range":"(10 – 59) dm3/min"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (5 - 35) oC\nPrzepływ powietrza\nZakres (10 – 59) dm3/min\nMetoda pomiarowa bezpośrednia","reference":"PB-17-31 wydanie 4 z dnia 30.05.2025 r.","norm_bases":["PB-17-31 wydanie 4 z dnia 30.05.2025 r."],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - wydatek energetyczny Temperatura powietrza\nZakres:\nZakres (5 - 35) oC\nPrzepływ powietrza\nZakres (10 – 59) dm3/min\nMetoda pomiarowa bezpośrednia PB-17-31 wydanie 4 z dnia 30.05.2025 r. Srodowisko pracy - wydatek energetyczny Temperatura powietrza\nZakres:\nZakres (5 - 35) oC\nPrzeplyw powietrza\nZakres (10 – 59) dm3/min\nMetoda pomiarowa bezposrednia PB-17-31 wydanie 4 z dnia 30.05.2025 r.","categories":["environment"],"row_index":61,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(5 - 35) oC"},{"name":"空气流量"},{"name":"范围","range":"(10 – 59) dm3/min"}],"search_zh":"工作场所环境 — 能量消耗 空气温度 直接测量法 范围 空气流量 范围 PB-17-31 wydanie 4 z dnia 30.05.2025 r.","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 能量消耗"},{"_id":"6a864b0cfbf98dd0af9b1e4c","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - wydatek energetyczny","methodology":"Wydatek energetyczny (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wydatek energetyczny (z obliczeń)","reference":"PB-17-31 wydanie 4 z dnia 30.05.2025 r.","norm_bases":["PB-17-31 wydanie 4 z dnia 30.05.2025 r."],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - wydatek energetyczny Wydatek energetyczny (z obliczeń) PB-17-31 wydanie 4 z dnia 30.05.2025 r. Srodowisko pracy - wydatek energetyczny Wydatek energetyczny (z obliczen) PB-17-31 wydanie 4 z dnia 30.05.2025 r.","categories":["environment"],"row_index":62,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"能量消耗（计算值）","search_zh":"工作场所环境 — 能量消耗 能量消耗（计算值） PB-17-31 wydanie 4 z dnia 30.05.2025 r.","test_object_zh":"工作场所环境 — 能量消耗"},{"_id":"6a864b0cfbf98dd0af9b1e4d","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane do roztworu pochłaniającego","methodology":"Zawartość tlenku azotu","parameters":[{"name":"Zakres","range":"(0,0001 -0,008) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość tlenku azotu\nZakres (0,0001 -0,008) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-Z-04009-11:2008","norm_bases":["PN-Z-04009-11:2008"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane do roztworu pochłaniającego Zawartość tlenku azotu\nZakres (0,0001 -0,008) mg w próbce\nMetoda spektrofotometryczna PN-Z-04009-11:2008 Srodowisko pracy - probki powietrza pobrane do roztworu pochlaniajacego Zawartosc tlenku azotu\nZakres (0,0001 -0,008) mg w probce\nMetoda spektrofotometryczna PN-Z-04009-11:2008","categories":["environment"],"row_index":63,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,0001 -0,008) mg w próbce"}],"search_zh":"工作环境 － 采集于吸收液中的空气样品 一氧化氮含量 分光光度法 范围 PN-Z-04009-11:2008","technique_zh":"分光光度法","test_object_zh":"工作环境 － 采集于吸收液中的空气样品","methodology_zh":"一氧化氮含量"},{"_id":"6a864b0cfbf98dd0af9b1e4e","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane do roztworu pochłaniającego","methodology":"Zawartość ditlenku azotu","parameters":[{"name":"Zakres","range":"(0,0001 - 0,008) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość ditlenku azotu\nZakres (0,0001 - 0,008) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-Z-04009-11:2008","norm_bases":["PN-Z-04009-11:2008"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane do roztworu pochłaniającego Zawartość ditlenku azotu\nZakres (0,0001 - 0,008) mg w próbce\nMetoda spektrofotometryczna PN-Z-04009-11:2008 Srodowisko pracy - probki powietrza pobrane do roztworu pochlaniajacego Zawartosc ditlenku azotu\nZakres (0,0001 - 0,008) mg w probce\nMetoda spektrofotometryczna PN-Z-04009-11:2008","categories":["environment"],"row_index":64,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,0001 - 0,008) mg w próbce"}],"search_zh":"工作环境 － 采集于吸收液中的空气样品 二氧化氮含量 分光光度法 范围 PN-Z-04009-11:2008","technique_zh":"分光光度法","test_object_zh":"工作环境 － 采集于吸收液中的空气样品","methodology_zh":"二氧化氮含量"},{"_id":"6a864b0cfbf98dd0af9b1e4f","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na filtry","methodology":"Zawartość miedzi i jej związków nieorganicznych w przeliczeniu na Cu","parameters":[{"name":"Zakres","range":"(0,002 - 5,0) mg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Zawartość miedzi i jej związków nieorganicznych w przeliczeniu na Cu\nZakres (0,002 - 5,0) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PB-17-05 wydanie 5 z dnia 30.06.2022 r.","norm_bases":["PB-17-05 wydanie 5 z dnia 30.06.2022 r."],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na filtry Zawartość miedzi i jej związków nieorganicznych w przeliczeniu na Cu\nZakres (0,002 - 5,0) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB-17-05 wydanie 5 z dnia 30.06.2022 r. Srodowisko pracy - probki powietrza pobrane na filtry Zawartosc miedzi i jej zwiazkow nieorganicznych w przeliczeniu na Cu\nZakres (0,002 - 5,0) mg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB-17-05 wydanie 5 z dnia 30.06.2022 r.","categories":["environment"],"row_index":65,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,002 - 5,0) mg w próbce"}],"search_zh":"工作场所环境 — 用滤膜采集的空气样品 铜及其无机化合物含量（以 Cu 计） 火焰原子吸收光谱法（FAAS） 范围 PB-17-05 wydanie 5 z dnia 30.06.2022 r.","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 — 用滤膜采集的空气样品","methodology_zh":"铜及其无机化合物含量（以 Cu 计）"},{"_id":"6a864b0cfbf98dd0af9b1e50","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na filtry","methodology":"Zawartość manganu i jego związków nieorganicznych w przeliczeniu na Mn – frakcja wdychalna","parameters":[{"name":"Zakres","range":"(0,002 - 1,5) mg w próbce"},{"name":"– frakcja respirabilna"},{"name":"Zakres","range":"(0,002 - 1,5) mg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Zawartość manganu i jego związków nieorganicznych w przeliczeniu na Mn – frakcja wdychalna\nZakres:\nZakres (0,002 - 1,5) mg w próbce\n– frakcja respirabilna\nZakres (0,002 - 1,5) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PB-17-05 wydanie 5 z dnia 30.06.2022 r.","norm_bases":["PB-17-05 wydanie 5 z dnia 30.06.2022 r."],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na filtry Zawartość manganu i jego związków nieorganicznych w przeliczeniu na Mn – frakcja wdychalna\nZakres:\nZakres (0,002 - 1,5) mg w próbce\n– frakcja respirabilna\nZakres (0,002 - 1,5) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB-17-05 wydanie 5 z dnia 30.06.2022 r. Srodowisko pracy - probki powietrza pobrane na filtry Zawartosc manganu i jego zwiazkow nieorganicznych w przeliczeniu na Mn – frakcja wdychalna\nZakres:\nZakres (0,002 - 1,5) mg w probce\n– frakcja respirabilna\nZakres (0,002 - 1,5) mg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB-17-05 wydanie 5 z dnia 30.06.2022 r.","categories":["environment"],"row_index":66,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,002 - 1,5) mg w próbce"},{"name":"— 呼吸性组分"},{"name":"范围","range":"(0,002 - 1,5) mg w próbce"}],"search_zh":"工作场所环境 — 用滤膜采集的空气样品 火焰原子吸收光谱法（FAAS） 范围 — 呼吸性组分 范围 PB-17-05 wydanie 5 z dnia 30.06.2022 r.","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 — 用滤膜采集的空气样品"},{"_id":"6a864b0cfbf98dd0af9b1e51","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na filtry","methodology":"Zawartość tlenków cynku w przeliczeniu na Zn – frakcja wdychalna","parameters":[{"name":"Zakres","range":"(0,001 - 12,0) mg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Zawartość tlenków cynku w przeliczeniu na Zn – frakcja wdychalna\nZakres (0,001 - 12,0) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PB-17-05 wydanie 5 z dnia 30.06.2022 r.","norm_bases":["PB-17-05 wydanie 5 z dnia 30.06.2022 r."],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na filtry Zawartość tlenków cynku w przeliczeniu na Zn – frakcja wdychalna\nZakres (0,001 - 12,0) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB-17-05 wydanie 5 z dnia 30.06.2022 r. Srodowisko pracy - probki powietrza pobrane na filtry Zawartosc tlenkow cynku w przeliczeniu na Zn – frakcja wdychalna\nZakres (0,001 - 12,0) mg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB-17-05 wydanie 5 z dnia 30.06.2022 r.","categories":["environment"],"row_index":67,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,001 - 12,0) mg w próbce"}],"search_zh":"工作场所环境 — 用滤膜采集的空气样品 火焰原子吸收光谱法（FAAS） 范围 PB-17-05 wydanie 5 z dnia 30.06.2022 r.","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 — 用滤膜采集的空气样品"},{"_id":"6a864b0cfbf98dd0af9b1e52","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na filtry","methodology":"Zawartość tlenków żelaza w przeliczeniu na Fe – frakcja wdychalna","parameters":[{"name":"Zakres","range":"(0,003 – 7,7) mg w próbce"},{"name":"– frakcja respirabilna"},{"name":"Zakres","range":"(0,003 – 7,7) mg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii (FAAS)"],"computed":[],"activity":"Zawartość tlenków żelaza w przeliczeniu na Fe – frakcja wdychalna\nZakres:\nZakres (0,003 – 7,7) mg w próbce\n– frakcja respirabilna\nZakres (0,003 – 7,7) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii (FAAS)","reference":"PB-17-05 wydanie 5 z dnia 30.06.2022 r.","norm_bases":["PB-17-05 wydanie 5 z dnia 30.06.2022 r."],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na filtry Zawartość tlenków żelaza w przeliczeniu na Fe – frakcja wdychalna\nZakres:\nZakres (0,003 – 7,7) mg w próbce\n– frakcja respirabilna\nZakres (0,003 – 7,7) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii (FAAS) PB-17-05 wydanie 5 z dnia 30.06.2022 r. Srodowisko pracy - probki powietrza pobrane na filtry Zawartosc tlenkow zelaza w przeliczeniu na Fe – frakcja wdychalna\nZakres:\nZakres (0,003 – 7,7) mg w probce\n– frakcja respirabilna\nZakres (0,003 – 7,7) mg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii (FAAS) PB-17-05 wydanie 5 z dnia 30.06.2022 r.","categories":["environment"],"row_index":68,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,003 – 7,7) mg w próbce"},{"name":"— 呼吸性组分"},{"name":"范围","range":"(0,003 – 7,7) mg w próbce"}],"search_zh":"工作场所环境 — 用滤膜采集的空气样品 范围 — 呼吸性组分 范围 PB-17-05 wydanie 5 z dnia 30.06.2022 r.","test_object_zh":"工作场所环境 — 用滤膜采集的空气样品"},{"_id":"6a864b0cfbf98dd0af9b1e53","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na filtry","methodology":"Zawartość ołowiu i jego związków nieorganicznych w przeliczeniu na Pb","parameters":[{"name":"Zakres","range":"(0,0025 – 1,00) mg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Zawartość ołowiu i jego związków nieorganicznych w przeliczeniu na Pb\nZakres (0,0025 – 1,00) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PB-17-05 wydanie 5 z dnia 30.06.2022 r.","norm_bases":["PB-17-05 wydanie 5 z dnia 30.06.2022 r."],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na filtry Zawartość ołowiu i jego związków nieorganicznych w przeliczeniu na Pb\nZakres (0,0025 – 1,00) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB-17-05 wydanie 5 z dnia 30.06.2022 r. Srodowisko pracy - probki powietrza pobrane na filtry Zawartosc olowiu i jego zwiazkow nieorganicznych w przeliczeniu na Pb\nZakres (0,0025 – 1,00) mg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB-17-05 wydanie 5 z dnia 30.06.2022 r.","categories":["environment"],"row_index":69,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,0025 – 1,00) mg w próbce"}],"search_zh":"工作场所环境 — 用滤膜采集的空气样品 铅及其无机化合物含量（以 Pb 计） 火焰原子吸收光谱法（FAAS） 范围 PB-17-05 wydanie 5 z dnia 30.06.2022 r.","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 — 用滤膜采集的空气样品","methodology_zh":"铅及其无机化合物含量（以 Pb 计）"},{"_id":"6a864b0cfbf98dd0af9b1e54","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na filtry","methodology":"Zawartość wodorotlenku sodowego","parameters":[{"name":"Zakres","range":"(0,004 – 1,22) mg w próbce"}],"technique":"Metoda emisyjnej spektrometrii płomieniowej","techniques":["Metoda emisyjnej spektrometrii płomieniowej"],"computed":[],"activity":"Zawartość wodorotlenku sodowego\nZakres (0,004 – 1,22) mg w próbce\nMetoda emisyjnej spektrometrii płomieniowej","reference":"PN-Z-04435:2011 | PB-17-06 wydanie 4 z dnia 06.02.2013 r.","norm_bases":["PN-Z-04435:2011","PB-17-06 wydanie 4 z dnia 06.02.2013 r."],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na filtry Zawartość wodorotlenku sodowego\nZakres (0,004 – 1,22) mg w próbce\nMetoda emisyjnej spektrometrii płomieniowej PN-Z-04435:2011 | PB-17-06 wydanie 4 z dnia 06.02.2013 r. Srodowisko pracy - probki powietrza pobrane na filtry Zawartosc wodorotlenku sodowego\nZakres (0,004 – 1,22) mg w probce\nMetoda emisyjnej spektrometrii plomieniowej PN-Z-04435:2011 | PB-17-06 wydanie 4 z dnia 06.02.2013 r.","categories":["environment"],"row_index":70,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,004 – 1,22) mg w próbce"}],"search_zh":"工作场所环境 — 用滤膜采集的空气样品 火焰发射光谱法 范围 PN-Z-04435:2011 | PB-17-06 wydanie 4 z dnia 06.02.2013 r.","test_object_zh":"工作场所环境 — 用滤膜采集的空气样品","technique_zh":"火焰发射光谱法"},{"_id":"6a864b0cfbf98dd0af9b1e55","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na filtry","methodology":"Zawartość wodorotlenku potasowego","parameters":[{"name":"Zakres","range":"(0,004 – 1,44) mg w próbce"}],"technique":"Metoda emisyjnej spektrometrii płomieniowej","techniques":["Metoda emisyjnej spektrometrii płomieniowej"],"computed":[],"activity":"Zawartość wodorotlenku potasowego\nZakres (0,004 – 1,44) mg w próbce\nMetoda emisyjnej spektrometrii płomieniowej","reference":"PN-Z-04436:2011 | PB-17-06 wydanie 4 z dnia 06.02.2013 r.","norm_bases":["PN-Z-04436:2011","PB-17-06 wydanie 4 z dnia 06.02.2013 r."],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na filtry Zawartość wodorotlenku potasowego\nZakres (0,004 – 1,44) mg w próbce\nMetoda emisyjnej spektrometrii płomieniowej PN-Z-04436:2011 | PB-17-06 wydanie 4 z dnia 06.02.2013 r. Srodowisko pracy - probki powietrza pobrane na filtry Zawartosc wodorotlenku potasowego\nZakres (0,004 – 1,44) mg w probce\nMetoda emisyjnej spektrometrii plomieniowej PN-Z-04436:2011 | PB-17-06 wydanie 4 z dnia 06.02.2013 r.","categories":["environment"],"row_index":71,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,004 – 1,44) mg w próbce"}],"search_zh":"工作场所环境 — 用滤膜采集的空气样品 火焰发射光谱法 范围 PN-Z-04436:2011 | PB-17-06 wydanie 4 z dnia 06.02.2013 r.","test_object_zh":"工作场所环境 — 用滤膜采集的空气样品","technique_zh":"火焰发射光谱法"},{"_id":"6a864b0cfbf98dd0af9b1e56","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na rurki z sorbentem","methodology":"Zawartość etylobenzenu","parameters":[{"name":"Zakres","range":"(3,8-18751) μg w próbce"},{"name":"Zawartość kumenu"},{"name":"Zakres","range":"(9,3-18506) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość etylobenzenu\nZakres:\nZakres (3,8-18751) μg w próbce\nZawartość kumenu\nZakres (9,3-18506) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 *","norm_bases":["PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 *"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na rurki z sorbentem Zawartość etylobenzenu\nZakres:\nZakres (3,8-18751) μg w próbce\nZawartość kumenu\nZakres (9,3-18506) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 * Srodowisko pracy - probki powietrza pobrane na rurki z sorbentem Zawartosc etylobenzenu\nZakres:\nZakres (3,8-18751) μg w probce\nZawartosc kumenu\nZakres (9,3-18506) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wylaczeniem pkt. 5.4 *","categories":["environment"],"row_index":72,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(3,8-18751) μg w próbce"},{"name":"Zawartość kumenu"},{"name":"范围","range":"(9,3-18506) μg w próbce"}],"search_zh":"工作场所环境 — 用吸附管采集的空气样品 乙苯含量 气相色谱-火焰离子化检测法（GC-FID） 范围 范围 PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 *","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 用吸附管采集的空气样品","methodology_zh":"乙苯含量"},{"_id":"6a864b0cfbf98dd0af9b1e57","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na rurki z sorbentem","methodology":"Szkodliwe substancje wydzielające się z wyrobów lakierowych nitrocelulozowych:","parameters":[{"name":"aceton"},{"name":"Zakres","range":"(9,6-48190) μg w próbce"},{"name":"butan-1-ol"},{"name":"Zakres","range":"(9,0-17960) μg w próbce"},{"name":"2-metylopropan-1-ol"},{"name":"Zakres","range":"(9,0-17735) μg w próbce"},{"name":"toluen"},{"name":"Zakres","range":"(3,8-18957) μg w próbce"},{"name":"ksylen – mieszanina izomerów 1,2;1,3;1,4"},{"name":"Zakres","range":"(3,8-19320) μg w próbce"},{"name":"octan etylu"},{"name":"Zakres","range":"(7,5-37562) μg w próbce"},{"name":"octan butylu"},{"name":"Zakres","range":"(9,7-19498) μg w próbce"},{"name":"etanolu"},{"name":"Zakres","range":"(41-81964) μg w próbce"},{"name":"2-butoksyetanol"},{"name":"Zakres","range":"(3,9-19617) μg w próbce"},{"name":"2-etoksyetanol"},{"name":"Zakres","range":"(4,0-20540) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Szkodliwe substancje wydzielające się z wyrobów lakierowych nitrocelulozowych:\nZakres:\naceton\nZakres (9,6-48190) μg w próbce\nbutan-1-ol\nZakres (9,0-17960) μg w próbce\n2-metylopropan-1-ol\nZakres (9,0-17735) μg w próbce\ntoluen\nZakres (3,8-18957) μg w próbce\nksylen – mieszanina izomerów 1,2;1,3;1,4\nZakres (3,8-19320) μg w próbce\noctan etylu\nZakres (7,5-37562) μg w próbce\noctan butylu\nZakres (9,7-19498) μg w próbce\netanolu\nZakres (41-81964) μg w próbce\n2-butoksyetanol\nZakres (3,9-19617) μg w próbce\n2-etoksyetanol\nZakres (4,0-20540) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PN-89/Z-04023.02 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 *","norm_bases":["PN-89/Z-04023.02","PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 *"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na rurki z sorbentem Szkodliwe substancje wydzielające się z wyrobów lakierowych nitrocelulozowych:\nZakres:\naceton\nZakres (9,6-48190) μg w próbce\nbutan-1-ol\nZakres (9,0-17960) μg w próbce\n2-metylopropan-1-ol\nZakres (9,0-17735) μg w próbce\ntoluen\nZakres (3,8-18957) μg w próbce\nksylen – mieszanina izomerów 1,2;1,3;1,4\nZakres (3,8-19320) μg w próbce\noctan etylu\nZakres (7,5-37562) μg w próbce\noctan butylu\nZakres (9,7-19498) μg w próbce\netanolu\nZakres (41-81964) μg w próbce\n2-butoksyetanol\nZakres (3,9-19617) μg w próbce\n2-etoksyetanol\nZakres (4,0-20540) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PN-89/Z-04023.02 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 * Srodowisko pracy - probki powietrza pobrane na rurki z sorbentem Szkodliwe substancje wydzielajace sie z wyrobow lakierowych nitrocelulozowych:\nZakres:\naceton\nZakres (9,6-48190) μg w probce\nbutan-1-ol\nZakres (9,0-17960) μg w probce\n2-metylopropan-1-ol\nZakres (9,0-17735) μg w probce\ntoluen\nZakres (3,8-18957) μg w probce\nksylen – mieszanina izomerow 1,2;1,3;1,4\nZakres (3,8-19320) μg w probce\noctan etylu\nZakres (7,5-37562) μg w probce\noctan butylu\nZakres (9,7-19498) μg w probce\netanolu\nZakres (41-81964) μg w probce\n2-butoksyetanol\nZakres (3,9-19617) μg w probce\n2-etoksyetanol\nZakres (4,0-20540) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PN-89/Z-04023.02 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wylaczeniem pkt. 5.4 *","categories":["environment","automotive"],"row_index":73,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"丙酮"},{"name":"范围","range":"(9,6-48190) μg w próbce"},{"name":"正丁醇"},{"name":"范围","range":"(9,0-17960) μg w próbce"},{"name":"异丁醇"},{"name":"范围","range":"(9,0-17735) μg w próbce"},{"name":"甲苯"},{"name":"范围","range":"(3,8-18957) μg w próbce"},{"name":"ksylen – mieszanina izomerów 1,2;1,3;1,4"},{"name":"范围","range":"(3,8-19320) μg w próbce"},{"name":"乙酸乙酯"},{"name":"范围","range":"(7,5-37562) μg w próbce"},{"name":"乙酸丁酯"},{"name":"范围","range":"(9,7-19498) μg w próbce"},{"name":"etanolu"},{"name":"范围","range":"(41-81964) μg w próbce"},{"name":"2-丁氧基乙醇"},{"name":"范围","range":"(3,9-19617) μg w próbce"},{"name":"2-乙氧基乙醇"},{"name":"范围","range":"(4,0-20540) μg w próbce"}],"search_zh":"工作场所环境 — 用吸附管采集的空气样品 气相色谱-火焰离子化检测法（GC-FID） 丙酮 范围 正丁醇 范围 异丁醇 范围 甲苯 范围 范围 乙酸乙酯 范围 乙酸丁酯 范围 范围 2-丁氧基乙醇 范围 2-乙氧基乙醇 范围 PN-89/Z-04023.02 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 *","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 用吸附管采集的空气样品"},{"_id":"6a864b0cfbf98dd0af9b1e58","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na rurki z sorbentem","methodology":"Zawartość octanu metylu","parameters":[{"name":"Zakres","range":"(4,0-20056) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość octanu metylu\nZakres (4,0-20056) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PN-78/Z-04119.01 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 *","norm_bases":["PN-78/Z-04119.01","PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 *"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na rurki z sorbentem Zawartość octanu metylu\nZakres (4,0-20056) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PN-78/Z-04119.01 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 * Srodowisko pracy - probki powietrza pobrane na rurki z sorbentem Zawartosc octanu metylu\nZakres (4,0-20056) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PN-78/Z-04119.01 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wylaczeniem pkt. 5.4 *","categories":["environment"],"row_index":74,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(4,0-20056) μg w próbce"}],"search_zh":"工作场所环境 — 用吸附管采集的空气样品 气相色谱-火焰离子化检测法（GC-FID） 范围 PN-78/Z-04119.01 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 *","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 用吸附管采集的空气样品"},{"_id":"6a864b0cfbf98dd0af9b1e59","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na rurki z sorbentem","methodology":"Zawartość butan-2-onu","parameters":[{"name":"Zakres","range":"(5,0-25661) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość butan-2-onu\nZakres (5,0-25661) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 *","norm_bases":["PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 *"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na rurki z sorbentem Zawartość butan-2-onu\nZakres (5,0-25661) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 * Srodowisko pracy - probki powietrza pobrane na rurki z sorbentem Zawartosc butan-2-onu\nZakres (5,0-25661) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wylaczeniem pkt. 5.4 *","categories":["environment"],"row_index":75,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(5,0-25661) μg w próbce"}],"search_zh":"工作场所环境 — 用吸附管采集的空气样品 气相色谱-火焰离子化检测法（GC-FID） 范围 PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 *","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 用吸附管采集的空气样品"},{"_id":"6a864b0cfbf98dd0af9b1e5a","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na rurki z sorbentem","methodology":"Zawartość styrenu","parameters":[{"name":"Zakres","range":"(9,9-19808) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość styrenu\nZakres (9,9-19808) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PN-86/Z-04152.02 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 *","norm_bases":["PN-86/Z-04152.02","PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 *"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na rurki z sorbentem Zawartość styrenu\nZakres (9,9-19808) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PN-86/Z-04152.02 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 * Srodowisko pracy - probki powietrza pobrane na rurki z sorbentem Zawartosc styrenu\nZakres (9,9-19808) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PN-86/Z-04152.02 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wylaczeniem pkt. 5.4 *","categories":["environment"],"row_index":76,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(9,9-19808) μg w próbce"}],"search_zh":"工作场所环境 — 用吸附管采集的空气样品 苯乙烯含量 气相色谱-火焰离子化检测法（GC-FID） 范围 PN-86/Z-04152.02 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 *","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 用吸附管采集的空气样品","methodology_zh":"苯乙烯含量"},{"_id":"6a864b0cfbf98dd0af9b1e5b","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na rurki z sorbentem","methodology":"Zawartość tetrachloroetenu","parameters":[{"name":"Zakres","range":"(17-34379) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość tetrachloroetenu\nZakres (17-34379) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PN-Z-04325:2006 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 *","norm_bases":["PN-Z-04325:2006","PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 *"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na rurki z sorbentem Zawartość tetrachloroetenu\nZakres (17-34379) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PN-Z-04325:2006 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 * Srodowisko pracy - probki powietrza pobrane na rurki z sorbentem Zawartosc tetrachloroetenu\nZakres (17-34379) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PN-Z-04325:2006 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wylaczeniem pkt. 5.4 *","categories":["environment"],"row_index":77,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(17-34379) μg w próbce"}],"search_zh":"工作场所环境 — 用吸附管采集的空气样品 四氯乙烯含量 气相色谱-火焰离子化检测法（GC-FID） 范围 PN-Z-04325:2006 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 *","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 用吸附管采集的空气样品","methodology_zh":"四氯乙烯含量"},{"_id":"6a864b0cfbf98dd0af9b1e5c","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na rurki z sorbentem","methodology":"Zawartość trichloroetenu","parameters":[{"name":"Zakres","range":"(15-30869) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość trichloroetenu\nZakres (15-30869) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PN-Z-04325:2006 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 *","norm_bases":["PN-Z-04325:2006","PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 *"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na rurki z sorbentem Zawartość trichloroetenu\nZakres (15-30869) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PN-Z-04325:2006 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 * Srodowisko pracy - probki powietrza pobrane na rurki z sorbentem Zawartosc trichloroetenu\nZakres (15-30869) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PN-Z-04325:2006 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wylaczeniem pkt. 5.4 *","categories":["environment"],"row_index":78,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(15-30869) μg w próbce"}],"search_zh":"工作场所环境 — 用吸附管采集的空气样品 气相色谱-火焰离子化检测法（GC-FID） 范围 PN-Z-04325:2006 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 *","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 用吸附管采集的空气样品"},{"_id":"6a864b0cfbf98dd0af9b1e5d","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na rurki z sorbentem","methodology":"Zawartość 4-metylopentan-2-onu","parameters":[{"name":"Zakres","range":"(3,6-17709) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość 4-metylopentan-2-onu\nZakres (3,6-17709) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2001, 4 (30) | PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 *","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2001, 4 (30)","PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 *"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na rurki z sorbentem Zawartość 4-metylopentan-2-onu\nZakres (3,6-17709) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) Podstawy i Metody Oceny Środowiska Pracy 2001, 4 (30) | PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 * Srodowisko pracy - probki powietrza pobrane na rurki z sorbentem Zawartosc 4-metylopentan-2-onu\nZakres (3,6-17709) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) Podstawy i Metody Oceny Srodowiska Pracy 2001, 4 (30) | PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wylaczeniem pkt. 5.4 *","categories":["environment"],"row_index":79,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(3,6-17709) μg w próbce"}],"search_zh":"工作场所环境 — 用吸附管采集的空气样品 4-甲基-2-戊酮含量 气相色谱-火焰离子化检测法（GC-FID） 范围 Podstawy i Metody Oceny Środowiska Pracy 2001, 4 (30) | PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 *","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 用吸附管采集的空气样品","methodology_zh":"4-甲基-2-戊酮含量"},{"_id":"6a864b0cfbf98dd0af9b1e5e","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na rurki z sorbentem","methodology":"Zawartość 3-metylobutan-1-olu","parameters":[{"name":"Zakres","range":"(9,0-17956) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość 3-metylobutan-1-olu\nZakres (9,0-17956) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PN-Z-04355:2005 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 *","norm_bases":["PN-Z-04355:2005","PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 *"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na rurki z sorbentem Zawartość 3-metylobutan-1-olu\nZakres (9,0-17956) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PN-Z-04355:2005 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 * Srodowisko pracy - probki powietrza pobrane na rurki z sorbentem Zawartosc 3-metylobutan-1-olu\nZakres (9,0-17956) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PN-Z-04355:2005 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wylaczeniem pkt. 5.4 *","categories":["environment"],"row_index":80,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(9,0-17956) μg w próbce"}],"search_zh":"工作场所环境 — 用吸附管采集的空气样品 气相色谱-火焰离子化检测法（GC-FID） 范围 PN-Z-04355:2005 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 *","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 用吸附管采集的空气样品"},{"_id":"6a864b0cfbf98dd0af9b1e5f","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na rurki z sorbentem","methodology":"Zawartość acetonitrylu","parameters":[{"name":"Zakres","range":"(8,3-16656) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość acetonitrylu\nZakres (8,3-16656) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PN-Z-04244-02:1996 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 *","norm_bases":["PN-Z-04244-02:1996","PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 *"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na rurki z sorbentem Zawartość acetonitrylu\nZakres (8,3-16656) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PN-Z-04244-02:1996 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 * Srodowisko pracy - probki powietrza pobrane na rurki z sorbentem Zawartosc acetonitrylu\nZakres (8,3-16656) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PN-Z-04244-02:1996 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wylaczeniem pkt. 5.4 *","categories":["environment"],"row_index":81,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(8,3-16656) μg w próbce"}],"search_zh":"工作场所环境 — 用吸附管采集的空气样品 气相色谱-火焰离子化检测法（GC-FID） 范围 PN-Z-04244-02:1996 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 *","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 用吸附管采集的空气样品"},{"_id":"6a864b0cfbf98dd0af9b1e60","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na rurki z sorbentem","methodology":"Zawartość propan-2-olu","parameters":[{"name":"Zakres","range":"(24,0-48474) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość propan-2-olu\nZakres (24,0-48474) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PN-92/Z-04224.02 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 *","norm_bases":["PN-92/Z-04224.02","PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 *"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na rurki z sorbentem Zawartość propan-2-olu\nZakres (24,0-48474) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PN-92/Z-04224.02 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 * Srodowisko pracy - probki powietrza pobrane na rurki z sorbentem Zawartosc propan-2-olu\nZakres (24,0-48474) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PN-92/Z-04224.02 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wylaczeniem pkt. 5.4 *","categories":["environment"],"row_index":82,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(24,0-48474) μg w próbce"}],"search_zh":"工作场所环境 — 用吸附管采集的空气样品 异丙醇含量 气相色谱-火焰离子化检测法（GC-FID） 范围 PN-92/Z-04224.02 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 *","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 用吸附管采集的空气样品","methodology_zh":"异丙醇含量"},{"_id":"6a864b0cfbf98dd0af9b1e61","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na rurki z sorbentem","methodology":"Zawartość octanu winylu","parameters":[{"name":"Zakres","range":"(10-20297) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość octanu winylu\nZakres (10-20297) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PN-87/Z-04178.02 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 *","norm_bases":["PN-87/Z-04178.02","PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 *"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na rurki z sorbentem Zawartość octanu winylu\nZakres (10-20297) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PN-87/Z-04178.02 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 * Srodowisko pracy - probki powietrza pobrane na rurki z sorbentem Zawartosc octanu winylu\nZakres (10-20297) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PN-87/Z-04178.02 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wylaczeniem pkt. 5.4 *","categories":["environment"],"row_index":83,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(10-20297) μg w próbce"}],"search_zh":"工作场所环境 — 用吸附管采集的空气样品 乙酸乙烯酯含量 气相色谱-火焰离子化检测法（GC-FID） 范围 PN-87/Z-04178.02 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 *","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 用吸附管采集的空气样品","methodology_zh":"乙酸乙烯酯含量"},{"_id":"6a864b0cfbf98dd0af9b1e62","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na rurki z sorbentem","methodology":"Zawartość nafty","parameters":[{"name":"Zakres","range":"(17-17054) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość nafty\nZakres (17-17054) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PN-92/Z-04227.02 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 *","norm_bases":["PN-92/Z-04227.02","PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 *"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na rurki z sorbentem Zawartość nafty\nZakres (17-17054) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PN-92/Z-04227.02 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 * Srodowisko pracy - probki powietrza pobrane na rurki z sorbentem Zawartosc nafty\nZakres (17-17054) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PN-92/Z-04227.02 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wylaczeniem pkt. 5.4 *","categories":["environment"],"row_index":84,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(17-17054) μg w próbce"}],"search_zh":"工作场所环境 — 用吸附管采集的空气样品 煤油含量 气相色谱-火焰离子化检测法（GC-FID） 范围 PN-92/Z-04227.02 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 *","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 用吸附管采集的空气样品","methodology_zh":"煤油含量"},{"_id":"6a864b0cfbf98dd0af9b1e63","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na rurki z sorbentem","methodology":"Zawartość pentanu","parameters":[{"name":"Zakres","range":"(38-75662) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość pentanu\nZakres (38-75662) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 *","norm_bases":["PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 *"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na rurki z sorbentem Zawartość pentanu\nZakres (38-75662) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 * Srodowisko pracy - probki powietrza pobrane na rurki z sorbentem Zawartosc pentanu\nZakres (38-75662) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wylaczeniem pkt. 5.4 *","categories":["environment"],"row_index":85,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(38-75662) μg w próbce"}],"search_zh":"工作场所环境 — 用吸附管采集的空气样品 戊烷含量 气相色谱-火焰离子化检测法（GC-FID） 范围 PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 *","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 用吸附管采集的空气样品","methodology_zh":"戊烷含量"},{"_id":"6a864b0cfbf98dd0af9b1e64","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na rurki z sorbentem","methodology":"Zawartość heksanu","parameters":[{"name":"Zakres","range":"(7,3-14504) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość heksanu\nZakres (7,3-14504) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2011, 1 (67) | PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 *","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2011, 1 (67)","PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 *"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na rurki z sorbentem Zawartość heksanu\nZakres (7,3-14504) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) Podstawy i Metody Oceny Środowiska Pracy 2011, 1 (67) | PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 * Srodowisko pracy - probki powietrza pobrane na rurki z sorbentem Zawartosc heksanu\nZakres (7,3-14504) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) Podstawy i Metody Oceny Srodowiska Pracy 2011, 1 (67) | PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wylaczeniem pkt. 5.4 *","categories":["environment"],"row_index":86,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(7,3-14504) μg w próbce"}],"search_zh":"工作场所环境 — 用吸附管采集的空气样品 正己烷含量 气相色谱-火焰离子化检测法（GC-FID） 范围 Podstawy i Metody Oceny Środowiska Pracy 2011, 1 (67) | PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 *","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 用吸附管采集的空气样品","methodology_zh":"正己烷含量"},{"_id":"6a864b0cfbf98dd0af9b1e65","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na rurki z sorbentem","methodology":"Zawartość heptanu","parameters":[{"name":"Zakres","range":"(28,0-55941) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość heptanu\nZakres (28,0-55941) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2004, 4 (42) | PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 *","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2004, 4 (42)","PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 *"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na rurki z sorbentem Zawartość heptanu\nZakres (28,0-55941) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) Podstawy i Metody Oceny Środowiska Pracy 2004, 4 (42) | PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 * Srodowisko pracy - probki powietrza pobrane na rurki z sorbentem Zawartosc heptanu\nZakres (28,0-55941) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) Podstawy i Metody Oceny Srodowiska Pracy 2004, 4 (42) | PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wylaczeniem pkt. 5.4 *","categories":["environment"],"row_index":87,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(28,0-55941) μg w próbce"}],"search_zh":"工作场所环境 — 用吸附管采集的空气样品 气相色谱-火焰离子化检测法（GC-FID） 范围 Podstawy i Metody Oceny Środowiska Pracy 2004, 4 (42) | PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 *","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 用吸附管采集的空气样品"},{"_id":"6a864b0cfbf98dd0af9b1e66","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na rurki z sorbentem","methodology":"Zawartość metylocykloheksanu","parameters":[{"name":"Zakres","range":"(39-77610) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość metylocykloheksanu\nZakres (39-77610) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2011, 1 (67) | PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 *","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2011, 1 (67)","PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 *"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na rurki z sorbentem Zawartość metylocykloheksanu\nZakres (39-77610) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) Podstawy i Metody Oceny Środowiska Pracy 2011, 1 (67) | PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 * Srodowisko pracy - probki powietrza pobrane na rurki z sorbentem Zawartosc metylocykloheksanu\nZakres (39-77610) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) Podstawy i Metody Oceny Srodowiska Pracy 2011, 1 (67) | PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wylaczeniem pkt. 5.4 *","categories":["environment"],"row_index":88,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(39-77610) μg w próbce"}],"search_zh":"工作场所环境 — 用吸附管采集的空气样品 气相色谱-火焰离子化检测法（GC-FID） 范围 Podstawy i Metody Oceny Środowiska Pracy 2011, 1 (67) | PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 *","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 用吸附管采集的空气样品"},{"_id":"6a864b0cfbf98dd0af9b1e67","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na rurki z sorbentem","methodology":"Zawartość trimetylobenzenu – mieszaniny izomerów 1,2,3;1,2,4;1,3,5","parameters":[{"name":"Zakres","range":"(9,4 - 19653) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość trimetylobenzenu – mieszaniny izomerów 1,2,3;1,2,4;1,3,5\nZakres (9,4 - 19653) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PN-Z-04016-4:1998 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 *","norm_bases":["PN-Z-04016-4:1998","PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 *"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na rurki z sorbentem Zawartość trimetylobenzenu – mieszaniny izomerów 1,2,3;1,2,4;1,3,5\nZakres (9,4 - 19653) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PN-Z-04016-4:1998 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 * Srodowisko pracy - probki powietrza pobrane na rurki z sorbentem Zawartosc trimetylobenzenu – mieszaniny izomerow 1,2,3;1,2,4;1,3,5\nZakres (9,4 - 19653) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PN-Z-04016-4:1998 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wylaczeniem pkt. 5.4 *","categories":["environment"],"row_index":89,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(9,4 - 19653) μg w próbce"}],"search_zh":"工作场所环境 — 用吸附管采集的空气样品 气相色谱-火焰离子化检测法（GC-FID） 范围 PN-Z-04016-4:1998 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 *","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 用吸附管采集的空气样品"},{"_id":"6a864b0cfbf98dd0af9b1e68","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na rurki z sorbentem","methodology":"Zawartość 2-furylometanolu","parameters":[{"name":"Zakres","range":"(12-24571) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość 2-furylometanolu\nZakres (12-24571) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PN-90/Z-04214.02 | PB-17-21 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.3 *","norm_bases":["PN-90/Z-04214.02","PB-17-21 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.3 *"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na rurki z sorbentem Zawartość 2-furylometanolu\nZakres (12-24571) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PN-90/Z-04214.02 | PB-17-21 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.3 * Srodowisko pracy - probki powietrza pobrane na rurki z sorbentem Zawartosc 2-furylometanolu\nZakres (12-24571) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PN-90/Z-04214.02 | PB-17-21 wydanie 7 z dnia 20.06.2022 r. z wylaczeniem pkt. 5.3 *","categories":["environment"],"row_index":90,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(12-24571) μg w próbce"}],"search_zh":"工作场所环境 — 用吸附管采集的空气样品 气相色谱-火焰离子化检测法（GC-FID） 范围 PN-90/Z-04214.02 | PB-17-21 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.3 *","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 用吸附管采集的空气样品"},{"_id":"6a864b0cfbf98dd0af9b1e69","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na rurki z sorbentem","methodology":"Zawartość kwasu octowego","parameters":[{"name":"Zakres","range":"(10-21110) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość kwasu octowego\nZakres (10-21110) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PN-Z-04323:2004 | PB-17-21 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.3 *","norm_bases":["PN-Z-04323:2004","PB-17-21 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.3 *"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na rurki z sorbentem Zawartość kwasu octowego\nZakres (10-21110) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PN-Z-04323:2004 | PB-17-21 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.3 * Srodowisko pracy - probki powietrza pobrane na rurki z sorbentem Zawartosc kwasu octowego\nZakres (10-21110) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PN-Z-04323:2004 | PB-17-21 wydanie 7 z dnia 20.06.2022 r. z wylaczeniem pkt. 5.3 *","categories":["environment"],"row_index":91,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(10-21110) μg w próbce"}],"search_zh":"工作场所环境 — 用吸附管采集的空气样品 乙酸含量 气相色谱-火焰离子化检测法（GC-FID） 范围 PN-Z-04323:2004 | PB-17-21 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.3 *","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 用吸附管采集的空气样品","methodology_zh":"乙酸含量"},{"_id":"6a864b0cfbf98dd0af9b1e6a","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na rurki z sorbentem","methodology":"Zawartość fenolu","parameters":[{"name":"Zakres","range":"(1,5-1500) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość fenolu\nZakres (1,5-1500) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"Podstawy i Metody Oceny Środowiska Pracy 1999, nr 22 | PB-17-21 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.3 *","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 1999, nr 22","PB-17-21 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.3 *"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na rurki z sorbentem Zawartość fenolu\nZakres (1,5-1500) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) Podstawy i Metody Oceny Środowiska Pracy 1999, nr 22 | PB-17-21 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.3 * Srodowisko pracy - probki powietrza pobrane na rurki z sorbentem Zawartosc fenolu\nZakres (1,5-1500) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) Podstawy i Metody Oceny Srodowiska Pracy 1999, nr 22 | PB-17-21 wydanie 7 z dnia 20.06.2022 r. z wylaczeniem pkt. 5.3 *","categories":["environment"],"row_index":92,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(1,5-1500) μg w próbce"}],"search_zh":"工作场所环境 — 用吸附管采集的空气样品 苯酚含量 气相色谱-火焰离子化检测法（GC-FID） 范围 Podstawy i Metody Oceny Środowiska Pracy 1999, nr 22 | PB-17-21 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.3 *","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 用吸附管采集的空气样品","methodology_zh":"苯酚含量"},{"_id":"6a864b0cfbf98dd0af9b1e6b","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na rurki z sorbentem","methodology":"Zawartość naftalenu","parameters":[{"name":"Zakres","range":"(47-1240) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość naftalenu\nZakres (47-1240) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PN-Z-04098-3:2005 | PB-17-21 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.3 *","norm_bases":["PN-Z-04098-3:2005","PB-17-21 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.3 *"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na rurki z sorbentem Zawartość naftalenu\nZakres (47-1240) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PN-Z-04098-3:2005 | PB-17-21 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.3 * Srodowisko pracy - probki powietrza pobrane na rurki z sorbentem Zawartosc naftalenu\nZakres (47-1240) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PN-Z-04098-3:2005 | PB-17-21 wydanie 7 z dnia 20.06.2022 r. z wylaczeniem pkt. 5.3 *","categories":["environment"],"row_index":93,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(47-1240) μg w próbce"}],"search_zh":"工作场所环境 — 用吸附管采集的空气样品 气相色谱-火焰离子化检测法（GC-FID） 范围 PN-Z-04098-3:2005 | PB-17-21 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.3 *","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 用吸附管采集的空气样品"},{"_id":"6a864b0cfbf98dd0af9b1e6c","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na rurki z sorbentem","methodology":"Zawartość krezolu – mieszanina izomerów","parameters":[{"name":"Zakres","range":"(1,5-1500) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo - jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo - jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość krezolu – mieszanina izomerów\nZakres (1,5-1500) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo - jonizacyjną (GC-FID)","reference":"Podstawy i Metody Oceny Środowiska Pracy 1999, nr 22 | PB-17-21 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.3 *","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 1999, nr 22","PB-17-21 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.3 *"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na rurki z sorbentem Zawartość krezolu – mieszanina izomerów\nZakres (1,5-1500) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo - jonizacyjną (GC-FID) Podstawy i Metody Oceny Środowiska Pracy 1999, nr 22 | PB-17-21 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.3 * Srodowisko pracy - probki powietrza pobrane na rurki z sorbentem Zawartosc krezolu – mieszanina izomerow\nZakres (1,5-1500) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo - jonizacyjna (GC-FID) Podstawy i Metody Oceny Srodowiska Pracy 1999, nr 22 | PB-17-21 wydanie 7 z dnia 20.06.2022 r. z wylaczeniem pkt. 5.3 *","categories":["environment"],"row_index":94,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(1,5-1500) μg w próbce"}],"search_zh":"工作场所环境 — 用吸附管采集的空气样品 气相色谱-火焰离子化检测法（GC-FID） 范围 Podstawy i Metody Oceny Środowiska Pracy 1999, nr 22 | PB-17-21 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.3 *","test_object_zh":"工作场所环境 — 用吸附管采集的空气样品","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）"},{"_id":"6a864b0cfbf98dd0af9b1e6d","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na rurki z sorbentem","methodology":"Zawartość cykloheksanu","parameters":[{"name":"Zakres","range":"(6,0-32447) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość cykloheksanu\nZakres (6,0-32447) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2011, 1 (67) | PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 *","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2011, 1 (67)","PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 *"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na rurki z sorbentem Zawartość cykloheksanu\nZakres (6,0-32447) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) Podstawy i Metody Oceny Środowiska Pracy 2011, 1 (67) | PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 * Srodowisko pracy - probki powietrza pobrane na rurki z sorbentem Zawartosc cykloheksanu\nZakres (6,0-32447) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) Podstawy i Metody Oceny Srodowiska Pracy 2011, 1 (67) | PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wylaczeniem pkt. 5.4 *","categories":["environment"],"row_index":95,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(6,0-32447) μg w próbce"}],"search_zh":"工作场所环境 — 用吸附管采集的空气样品 环己烷含量 气相色谱-火焰离子化检测法（GC-FID） 范围 Podstawy i Metody Oceny Środowiska Pracy 2011, 1 (67) | PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 *","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 用吸附管采集的空气样品","methodology_zh":"环己烷含量"},{"_id":"6a864b0cfbf98dd0af9b1e6e","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na rurki z sorbentem","methodology":"Zawartość propan-1-olu","parameters":[{"name":"Zakres","range":"(13,0-25906) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość propan-1-olu\nZakres (13,0-25906) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PN-Z-04224-3:2003 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 * Dokumenty odniesienia","norm_bases":["PN-Z-04224-3:2003","PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 * Dokumenty odniesienia"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na rurki z sorbentem Zawartość propan-1-olu\nZakres (13,0-25906) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PN-Z-04224-3:2003 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 * Dokumenty odniesienia Srodowisko pracy - probki powietrza pobrane na rurki z sorbentem Zawartosc propan-1-olu\nZakres (13,0-25906) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PN-Z-04224-3:2003 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wylaczeniem pkt. 5.4 * Dokumenty odniesienia","categories":["environment"],"row_index":96,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(13,0-25906) μg w próbce"}],"search_zh":"工作场所环境 — 用吸附管采集的空气样品 气相色谱-火焰离子化检测法（GC-FID） 范围 PN-Z-04224-3:2003 | PB-17-27 wydanie 7 z dnia 20.06.2022 r. z wyłączeniem pkt. 5.4 * Dokumenty odniesienia","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 用吸附管采集的空气样品"},{"_id":"6a864b0cfbf98dd0af9b1e6f","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Ścieki, wody opadowe i roztopowe","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":"Metoda manualna; Metoda automatyczna","techniques":["Metoda manualna","Metoda automatyczna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, wody opadowe i roztopowe Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 Scieki, wody opadowe i roztopowe Pobieranie probek do badan chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":97,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"化学与物理检测用样品采集","search_zh":"废水、雨水与融雪水 化学与物理检测用样品采集 手动法；自动法 PN-ISO 5667-10:2021-11","technique_zh":"手动法；自动法","test_object_zh":"废水、雨水与融雪水"},{"_id":"6a864b0cfbf98dd0af9b1e70","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Ścieki, wody opadowe i roztopowe","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0 – 2000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 2000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, wody opadowe i roztopowe Zawiesiny ogólne\nZakres (2,0 – 2000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Scieki, wody opadowe i roztopowe Zawiesiny ogolne\nZakres (2,0 – 2000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":98,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 2000) mg/l"}],"search_zh":"废水、雨水与融雪水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"废水、雨水与融雪水"},{"_id":"6a864b0cfbf98dd0af9b1e71","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Ścieki, wody opadowe i roztopowe","methodology":"Indeks oleju mineralnego","parameters":[{"name":"Zakres","range":"(0,20 – 30) mg/l"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Indeks oleju mineralnego\nZakres (0,20 – 30) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PN-EN ISO 9377-2:2003 | PB-17-38 wydanie 2 z dnia 17.02.2014 r.","norm_bases":["PN-EN ISO 9377-2:2003","PB-17-38 wydanie 2 z dnia 17.02.2014 r."],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, wody opadowe i roztopowe Indeks oleju mineralnego\nZakres (0,20 – 30) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PN-EN ISO 9377-2:2003 | PB-17-38 wydanie 2 z dnia 17.02.2014 r. Scieki, wody opadowe i roztopowe Indeks oleju mineralnego\nZakres (0,20 – 30) mg/l\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PN-EN ISO 9377-2:2003 | PB-17-38 wydanie 2 z dnia 17.02.2014 r.","categories":["water","petro"],"row_index":99,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,20 – 30) mg/l"}],"search_zh":"废水、雨水与融雪水 矿物油指数 气相色谱-火焰离子化检测法（GC-FID） 范围 PN-EN ISO 9377-2:2003 | PB-17-38 wydanie 2 z dnia 17.02.2014 r.","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","methodology_zh":"矿物油指数","test_object_zh":"废水、雨水与融雪水"},{"_id":"6a864b0cfbf98dd0af9b1e72","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Scieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":100,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"污水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"污水"},{"_id":"6a864b0cfbf98dd0af9b1e73","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(1,0 – 400) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (1,0 – 400) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu amonowego\nZakres (1,0 – 400) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Scieki Stezenie azotu amonowego\nZakres (1,0 – 400) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":101,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(1,0 – 400) mg/l"}],"search_zh":"污水 氨氮浓度 分光光度法 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a864b0cfbf98dd0af9b1e74","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,0125 – 2,5) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres (0,0125 – 2,5) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu azotynowego\nZakres (0,0125 – 2,5) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Scieki Stezenie azotu azotynowego\nZakres (0,0125 – 2,5) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":102,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,0125 – 2,5) mg/l"}],"search_zh":"污水 亚硝态氮浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a864b0cfbf98dd0af9b1e75","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu azotanowego","parameters":[{"name":"Zakres","range":"(0,20 – 50) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotanowego\nZakres (0,20 – 50) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576.08","norm_bases":["PN-82/C-04576.08"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu azotanowego\nZakres (0,20 – 50) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08 Scieki Stezenie azotu azotanowego\nZakres (0,20 – 50) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08","categories":["water"],"row_index":103,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,20 – 50) mg/l"}],"search_zh":"污水 硝态氮浓度 分光光度法 范围 PN-82/C-04576.08","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a864b0cfbf98dd0af9b1e76","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(1,0 – 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (1,0 – 1000) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu Kjeldahla\nZakres (1,0 – 1000) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Scieki Stezenie azotu Kjeldahla\nZakres (1,0 – 1000) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":104,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(1,0 – 1000) mg/l"}],"search_zh":"污水 凯氏氮浓度 滴定法 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"污水"},{"_id":"6a864b0cfbf98dd0af9b1e77","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu ogólnego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PB-17-10 wydanie 2 z dnia 17.02.2014 r.","norm_bases":["PB-17-10 wydanie 2 z dnia 17.02.2014 r."],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu ogólnego (z obliczeń) PB-17-10 wydanie 2 z dnia 17.02.2014 r. Scieki Stezenie azotu ogolnego (z obliczen) PB-17-10 wydanie 2 z dnia 17.02.2014 r.","categories":["water"],"row_index":105,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"总氮浓度（计算值）","search_zh":"污水 总氮浓度（计算值） PB-17-10 wydanie 2 z dnia 17.02.2014 r.","test_object_zh":"污水"},{"_id":"6a864b0cfbf98dd0af9b1e78","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Ścieki","methodology":"Chemiczne zapotrzebowanie tlenu – ChZT-Cr","parameters":[{"name":"Zakres","range":"(30 – 7000) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu – ChZT-Cr\nZakres (30 – 7000) mg/l O2\nMetoda miareczkowa","reference":"PN-ISO 6060:2006","norm_bases":["PN-ISO 6060:2006"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Chemiczne zapotrzebowanie tlenu – ChZT-Cr\nZakres (30 – 7000) mg/l O2\nMetoda miareczkowa PN-ISO 6060:2006 Scieki Chemiczne zapotrzebowanie tlenu – ChZT-Cr\nZakres (30 – 7000) mg/l O2\nMetoda miareczkowa PN-ISO 6060:2006","categories":["water"],"row_index":106,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(30 – 7000) mg/l O2"}],"search_zh":"污水 化学需氧量（COD-Cr） 滴定法 范围 PN-ISO 6060:2006","technique_zh":"滴定法","test_object_zh":"污水","methodology_zh":"化学需氧量（COD-Cr）"},{"_id":"6a864b0cfbf98dd0af9b1e79","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu – BZT5","parameters":[{"name":"Zakres","range":"(3,0 – 6000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (3,0 – 6000) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (3,0 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Scieki Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (3,0 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":107,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(3,0 – 6000) mg/l O2"}],"search_zh":"污水 五日生化需氧量（BOD5） 电化学法 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"污水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a864b0cfbf98dd0af9b1e7a","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(10 – 5000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie siarczanów\nZakres (10 – 5000) mg/l\nMetoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie siarczanów\nZakres (10 – 5000) mg/l\nMetoda wagowa PN-ISO 9280:2002 Scieki Stezenie siarczanow\nZakres (10 – 5000) mg/l\nMetoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":108,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(10 – 5000) mg/l"}],"search_zh":"污水 硫酸盐浓度 重量法 范围 PN-ISO 9280:2002","technique_zh":"重量法","test_object_zh":"污水"},{"_id":"6a864b0cfbf98dd0af9b1e7b","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,050 – 80) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,050 – 80) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 pkt.8. + Ap1:2010 + Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 pkt.8. + Ap1:2010 + Ap2:2010"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie fosforu ogólnego\nZakres (0,050 – 80) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt.8. + Ap1:2010 + Ap2:2010 Scieki Stezenie fosforu ogolnego\nZakres (0,050 – 80) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt.8. + Ap1:2010 + Ap2:2010","categories":["water"],"row_index":109,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,050 – 80) mg/l"}],"search_zh":"污水 总磷浓度 分光光度法 范围 PN-EN ISO 6878:2006 pkt.8. + Ap1:2010 + Ap2:2010","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a864b0cfbf98dd0af9b1e7c","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5,0 – 2300) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5,0 – 2300) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie chlorków\nZakres (5,0 – 2300) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Scieki Stezenie chlorkow\nZakres (5,0 – 2300) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":110,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,0 – 2300) mg/l"}],"search_zh":"污水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"污水"},{"_id":"6a864b0cfbf98dd0af9b1e7d","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Ścieki","methodology":"Substancje rozpuszczone","parameters":[{"name":"Zakres","range":"(10 – 10 000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Substancje rozpuszczone\nZakres (10 – 10 000) mg/l\nMetoda wagowa","reference":"PB-17-18 wydanie 2 z dnia 17.02.2014 r.","norm_bases":["PB-17-18 wydanie 2 z dnia 17.02.2014 r."],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Substancje rozpuszczone\nZakres (10 – 10 000) mg/l\nMetoda wagowa PB-17-18 wydanie 2 z dnia 17.02.2014 r. Scieki Substancje rozpuszczone\nZakres (10 – 10 000) mg/l\nMetoda wagowa PB-17-18 wydanie 2 z dnia 17.02.2014 r.","categories":["water"],"row_index":111,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(10 – 10 000) mg/l"}],"search_zh":"污水 溶解性固体 重量法 范围 PB-17-18 wydanie 2 z dnia 17.02.2014 r.","technique_zh":"重量法","test_object_zh":"污水","methodology_zh":"溶解性固体"},{"_id":"6a864b0cfbf98dd0af9b1e7e","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie metali","parameters":[{"name":"cynk","range":"(0,05 – 70) mg/l"},{"name":"kadm","range":"(0,050 – 80) mg/l"},{"name":"ołów","range":"(0,25 – 400) mg/l"},{"name":"nikiel","range":"(0,10 – 250) mg/l"},{"name":"miedź","range":"(0,10 – 500) mg/l"},{"name":"kobalt","range":"(0,20 – 3,0) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie metali\nZakres:\ncynk (0,05 – 70) mg/l\nkadm (0,050 – 80) mg/l\nołów (0,25 – 400) mg/l\nnikiel (0,10 – 250) mg/l\nmiedź (0,10 – 500) mg/l\nkobalt (0,20 – 3,0) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 8288:2002 metoda A","norm_bases":["PN-ISO 8288:2002 metoda A"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie metali\nZakres:\ncynk (0,05 – 70) mg/l\nkadm (0,050 – 80) mg/l\nołów (0,25 – 400) mg/l\nnikiel (0,10 – 250) mg/l\nmiedź (0,10 – 500) mg/l\nkobalt (0,20 – 3,0) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 metoda A Scieki Stezenie metali\nZakres:\ncynk (0,05 – 70) mg/l\nkadm (0,050 – 80) mg/l\nolow (0,25 – 400) mg/l\nnikiel (0,10 – 250) mg/l\nmiedz (0,10 – 500) mg/l\nkobalt (0,20 – 3,0) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 metoda A","categories":["materials","water"],"row_index":112,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"金属浓度","parameters_zh":[{"name":"锌","range":"(0,05 – 70) mg/l"},{"name":"镉","range":"(0,050 – 80) mg/l"},{"name":"铅","range":"(0,25 – 400) mg/l"},{"name":"镍","range":"(0,10 – 250) mg/l"},{"name":"铜","range":"(0,10 – 500) mg/l"},{"name":"钴","range":"(0,20 – 3,0) mg/l"}],"search_zh":"污水 金属浓度 火焰原子吸收光谱法（FAAS） 锌 镉 铅 镍 铜 钴 PN-ISO 8288:2002 metoda A","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"污水"},{"_id":"6a864b0cfbf98dd0af9b1e7f","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie wapnia","parameters":[{"name":"Zakres","range":"(0,50 – 1000) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie wapnia\nZakres (0,50 – 1000) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-EN ISO 7980: 2002","norm_bases":["PN-EN ISO 7980: 2002"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie wapnia\nZakres (0,50 – 1000) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN ISO 7980: 2002 Scieki Stezenie wapnia\nZakres (0,50 – 1000) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN ISO 7980: 2002","categories":["water"],"row_index":113,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,50 – 1000) mg/l"}],"search_zh":"污水 钙浓度 火焰原子吸收光谱法（FAAS） 范围 PN-EN ISO 7980: 2002","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"污水","methodology_zh":"钙浓度"},{"_id":"6a864b0cfbf98dd0af9b1e80","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie metali","parameters":[{"name":"sód","range":"(0,10 – 7000) mg/l"},{"name":"potas","range":"(0,10 – 100) mg/l"}],"technique":"Metoda płomieniowej emisyjnej spektrometrii atomowej (FEAS)","techniques":["Metoda płomieniowej emisyjnej spektrometrii atomowej (FEAS)"],"computed":[],"activity":"Stężenie metali\nZakres:\nsód (0,10 – 7000) mg/l\npotas (0,10 – 100) mg/l\nMetoda płomieniowej emisyjnej spektrometrii atomowej (FEAS)","reference":"PN-ISO 9964-3:1994","norm_bases":["PN-ISO 9964-3:1994"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie metali\nZakres:\nsód (0,10 – 7000) mg/l\npotas (0,10 – 100) mg/l\nMetoda płomieniowej emisyjnej spektrometrii atomowej (FEAS) PN-ISO 9964-3:1994 Scieki Stezenie metali\nZakres:\nsod (0,10 – 7000) mg/l\npotas (0,10 – 100) mg/l\nMetoda plomieniowej emisyjnej spektrometrii atomowej (FEAS) PN-ISO 9964-3:1994","categories":["materials","water"],"row_index":114,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"金属浓度","search_zh":"污水 金属浓度 火焰原子发射光谱法（FEAS） 钠 钾 PN-ISO 9964-3:1994","test_object_zh":"污水","parameters_zh":[{"name":"钠","range":"(0,10 – 7000) mg/l"},{"name":"钾","range":"(0,10 – 100) mg/l"}],"technique_zh":"火焰原子发射光谱法（FEAS）"},{"_id":"6a864b0cfbf98dd0af9b1e81","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie chromu","parameters":[{"name":"Zakres","range":"(0,10 – 100) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie chromu\nZakres (0,10 – 100) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-EN 1233:2000","norm_bases":["PN-EN 1233:2000"],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie chromu\nZakres (0,10 – 100) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN 1233:2000 Scieki Stezenie chromu\nZakres (0,10 – 100) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN 1233:2000","categories":["water"],"row_index":115,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,10 – 100) mg/l"}],"search_zh":"污水 铬浓度 火焰原子吸收光谱法（FAAS） 范围 PN-EN 1233:2000","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"污水","methodology_zh":"铬浓度"},{"_id":"6a864b0cfbf98dd0af9b1e82","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie metali","parameters":[{"name":"mangan","range":"(0,10 – 150) mg/l"},{"name":"żelazo","range":"(0,25 – 1500) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie metali\nZakres:\nmangan (0,10 – 150) mg/l\nżelazo (0,25 – 1500) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PB-17-11 wydanie 2 z dnia 11.02.2013 r.","norm_bases":["PB-17-11 wydanie 2 z dnia 11.02.2013 r."],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie metali\nZakres:\nmangan (0,10 – 150) mg/l\nżelazo (0,25 – 1500) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB-17-11 wydanie 2 z dnia 11.02.2013 r. Scieki Stezenie metali\nZakres:\nmangan (0,10 – 150) mg/l\nzelazo (0,25 – 1500) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB-17-11 wydanie 2 z dnia 11.02.2013 r.","categories":["materials","water"],"row_index":116,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"金属浓度","search_zh":"污水 金属浓度 火焰原子吸收光谱法（FAAS） 锰 铁 PB-17-11 wydanie 2 z dnia 11.02.2013 r.","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"污水","parameters_zh":[{"name":"锰","range":"(0,10 – 150) mg/l"},{"name":"铁","range":"(0,25 – 1500) mg/l"}]},{"_id":"6a864b0cfbf98dd0af9b1e83","lab_id":"69ad52a3de79e566650fb29f","country":"PL","accr_number":"AB 522","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie srebra","parameters":[{"name":"Zakres","range":"(0,10 – 120) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie srebra\nZakres (0,10 – 120) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PB-17-23 wydanie 2 z dnia 11.02.2013 r.","norm_bases":["PB-17-23 wydanie 2 z dnia 11.02.2013 r."],"lab_section":"Laboratorium Ochrony Środowiska i Warunków Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie srebra\nZakres (0,10 – 120) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB-17-23 wydanie 2 z dnia 11.02.2013 r. Scieki Stezenie srebra\nZakres (0,10 – 120) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB-17-23 wydanie 2 z dnia 11.02.2013 r.","categories":["water"],"row_index":117,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,10 – 120) mg/l"}],"search_zh":"污水 银浓度 火焰原子吸收光谱法（FAAS） 范围 PB-17-23 wydanie 2 z dnia 11.02.2013 r.","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"污水","methodology_zh":"银浓度"}],"has_pdf":true}