{"lab":{"_id":"69ad52a3de79e566650fb289","accr_number":"AB 511","country":"PL","accr_body":"PCA","address":"ul. Chemików 7, 09-411 Płock, ORLEN Spółka Akcyjna - Oddział Upstream Polska w Zielonej Górze, ul. Bohaterów Westerplatte 15","categories":["petro","water"],"city":"Płock","imported_at":"2026-03-08T10:42:43.265Z","methods_count":9,"name":"ORLEN Spółka Akcyjna","parse_status":"parsed","parse_version":3,"pdf_files":["AB_511.pdf"],"scope_summary":"","search_text":"orlen spółka akcyjna ul. chemików 7, 09-411 płock, orlen spółka akcyjna - oddział upstream polska w zielonej górze, ul. bohaterów westerplatte 15 petro water other environment food","status":"active","updated_at":"2026-03-08T14:51:22.104Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-13T08:08:17.084Z","location":{"type":"Point","coordinates":[19.7065,52.5463]},"email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20511,podmiot.html","fields_of_testing":[{"codes":"C/10/P","pl":"Badania chemiczne i pobieranie próbek paliw gazowych","en":"Chemical tests and sampling of gas fuels"},{"codes":"C/47; C/48","pl":"Badania chemiczne ropy naftowej, innych przetworów naftowych","en":"Chemical tests of crude oil, other petroleum products"},{"codes":"N/10/P","pl":"Badanie właściwości fizycznych i pobieranie próbek paliw gazowych","en":"Physical properties and sampling of gas fuels"},{"codes":"N/47; N/48","pl":"Badanie właściwości fizycznych ropy naftowej, innych przetworów naftowych","en":"Physical properties of crude oil, other petroleum products"}],"issue":{"no":"26","date":"12.05.2026"},"parse_date":"2026-08-13T08:08:17.084Z","parse_source":"agent-claude-code","map_coord":[52.586402,19.653731],"map_geo":"nominatim-street","lab_locations":[{"name":"Laboratorium","address":null,"city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/13/86eebdcd9121acc2e261e16aa74f6796/AB%20511.pdf","has_en":true,"category_counts":{"petro":7,"water":2,"other":1},"category_scores":{"petro":4.9,"water":0.4,"other":0.1},"has_zh":true,"lab_locations_zh":[{"name":"实验室","address":null,"city":null,"postal":null}]},"methods":[{"_id":"6a7d7b710636ba417e41bd20","lab_id":"69ad52a3de79e566650fb289","country":"PL","accr_number":"AB 511","accr_body":"PCA","test_object":"Ropa naftowa","methodology":"Zawartość wody","parameters":[{"name":"Zakres","range":"(0,020 - 2,00) %(m/m)"}],"technique":"Metoda miareczkowania potencjometrycznego","techniques":["Metoda miareczkowania potencjometrycznego"],"computed":[],"activity":"Zawartość wody\nZakres (0,020 - 2,00) %(m/m)\nMetoda miareczkowania potencjometrycznego","reference":"ASTM D 4377-00 (2011)","norm_bases":["ASTM D 4377-00 (2011)"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ropa naftowa Zawartość wody\nZakres (0,020 - 2,00) %(m/m)\nMetoda miareczkowania potencjometrycznego ASTM D 4377-00 (2011) Ropa naftowa Zawartosc wody\nZakres (0,020 - 2,00) %(m/m)\nMetoda miareczkowania potencjometrycznego ASTM D 4377-00 (2011)","categories":["water","petro"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Water content","parameters_en":[{"name":"Range","range":"(0,020 - 2,00) %(m/m)"}],"search_en":"Crude oil Water content Potentiometric titration method Laboratory Range ASTM D 4377-00 (2011)","technique_en":"Potentiometric titration method","test_object_en":"Crude oil","lab_section_zh":"实验室","methodology_zh":"水分含量","parameters_zh":[{"name":"范围","range":"(0,020 - 2,00) %(m/m)"}],"search_zh":"原油 水分含量 电位滴定法 实验室 范围 ASTM D 4377-00 (2011)","technique_zh":"电位滴定法","test_object_zh":"原油"},{"_id":"6a7d7b710636ba417e41bd21","lab_id":"69ad52a3de79e566650fb289","country":"PL","accr_number":"AB 511","accr_body":"PCA","test_object":"Ropa naftowa","methodology":"Zawartość zanieczyszczeń stałych","parameters":[{"name":"Zakres","range":"(0,03 - 0,40) %(m/m)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość zanieczyszczeń stałych\nZakres (0,03 - 0,40) %(m/m)\nMetoda wagowa","reference":"PN-EN ISO 3735:2001","norm_bases":["PN-EN ISO 3735:2001"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ropa naftowa Zawartość zanieczyszczeń stałych\nZakres (0,03 - 0,40) %(m/m)\nMetoda wagowa PN-EN ISO 3735:2001 Ropa naftowa Zawartosc zanieczyszczen stalych\nZakres (0,03 - 0,40) %(m/m)\nMetoda wagowa PN-EN ISO 3735:2001","categories":["petro"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Content of solid impurities","parameters_en":[{"name":"Range","range":"(0,03 - 0,40) %(m/m)"}],"search_en":"Crude oil Content of solid impurities Gravimetric method Laboratory Range PN-EN ISO 3735:2001","technique_en":"Gravimetric method","test_object_en":"Crude oil","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(0,03 - 0,40) %(m/m)"}],"search_zh":"原油 重量法 实验室 范围 PN-EN ISO 3735:2001","technique_zh":"重量法","test_object_zh":"原油"},{"_id":"6a7d7b710636ba417e41bd22","lab_id":"69ad52a3de79e566650fb289","country":"PL","accr_number":"AB 511","accr_body":"PCA","test_object":"Ropa naftowa, Inne przetwory naftowe - kondensat naftowy","methodology":"Zawartość soli","parameters":[{"name":"Zakres","range":"(3,0 - 431) mg/l"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Zawartość soli\nZakres (3,0 - 431) mg/l\nMetoda konduktometryczna","reference":"ASTM D 3230-19","norm_bases":["ASTM D 3230-19"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ropa naftowa, Inne przetwory naftowe - kondensat naftowy Zawartość soli\nZakres (3,0 - 431) mg/l\nMetoda konduktometryczna ASTM D 3230-19 Ropa naftowa, Inne przetwory naftowe - kondensat naftowy Zawartosc soli\nZakres (3,0 - 431) mg/l\nMetoda konduktometryczna ASTM D 3230-19","categories":["petro"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Salt content","parameters_en":[{"name":"Range","range":"(3,0 - 431) mg/l"}],"search_en":"Crude oil, Other petroleum products - petroleum condensate Salt content Conductometric method Laboratory Range ASTM D 3230-19","technique_en":"Conductometric method","test_object_en":"Crude oil, Other petroleum products - petroleum condensate","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(3,0 - 431) mg/l"}],"search_zh":"盐含量 电导法 实验室 范围 ASTM D 3230-19","technique_zh":"电导法","methodology_zh":"盐含量"},{"_id":"6a7d7b710636ba417e41bd23","lab_id":"69ad52a3de79e566650fb289","country":"PL","accr_number":"AB 511","accr_body":"PCA","test_object":"Ropa naftowa, Inne przetwory naftowe - kondensat naftowy","methodology":"Gęstość w temp. 15 0C","parameters":[{"name":"Zakres","range":"(0,6500 – 0,9000) g/cm3"}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"computed":[],"activity":"Gęstość w temp. 15 0C\nZakres (0,6500 – 0,9000) g/cm3\nMetoda oscylacyjna","reference":"PN-EN ISO 12185:2024-08","norm_bases":["PN-EN ISO 12185:2024-08"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ropa naftowa, Inne przetwory naftowe - kondensat naftowy Gęstość w temp. 15 0C\nZakres (0,6500 – 0,9000) g/cm3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08 Ropa naftowa, Inne przetwory naftowe - kondensat naftowy Gestosc w temp. 15 0C\nZakres (0,6500 – 0,9000) g/cm3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08","categories":["petro"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Density at 15 0C","parameters_en":[{"name":"Range","range":"(0,6500 – 0,9000) g/cm3"}],"search_en":"Crude oil, Other petroleum products - petroleum condensate Density at 15 0C Oscillation method Laboratory Range PN-EN ISO 12185:2024-08","technique_en":"Oscillation method","test_object_en":"Crude oil, Other petroleum products - petroleum condensate","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(0,6500 – 0,9000) g/cm3"}],"search_zh":"振荡法 实验室 范围 PN-EN ISO 12185:2024-08","technique_zh":"振荡法"},{"_id":"6a7d7b710636ba417e41bd24","lab_id":"69ad52a3de79e566650fb289","country":"PL","accr_number":"AB 511","accr_body":"PCA","test_object":"Inne przetwory naftowe - kondensat naftowy","methodology":"Zawartość siarki","parameters":[{"name":"Zakres","range":"(5,0 - 3000) mg/kg"}],"technique":"Metoda fluorescencji w nadfiolecie","techniques":["Metoda fluorescencji w nadfiolecie"],"computed":[],"activity":"Zawartość siarki\nZakres (5,0 - 3000) mg/kg\nMetoda fluorescencji w nadfiolecie","reference":"ASTM D 5453-25","norm_bases":["ASTM D 5453-25"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Inne przetwory naftowe - kondensat naftowy Zawartość siarki\nZakres (5,0 - 3000) mg/kg\nMetoda fluorescencji w nadfiolecie ASTM D 5453-25 Inne przetwory naftowe - kondensat naftowy Zawartosc siarki\nZakres (5,0 - 3000) mg/kg\nMetoda fluorescencji w nadfiolecie ASTM D 5453-25","categories":["other"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Sulfur content","parameters_en":[{"name":"Range","range":"(5,0 - 3000) mg/kg"}],"search_en":"Other petroleum products - petroleum condensate Sulfur content Ultraviolet fluorescence method Laboratory Range ASTM D 5453-25","technique_en":"Ultraviolet fluorescence method","test_object_en":"Other petroleum products - petroleum condensate","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(5,0 - 3000) mg/kg"}],"search_zh":"硫含量 紫外荧光法 实验室 范围 ASTM D 5453-25","methodology_zh":"硫含量","technique_zh":"紫外荧光法"},{"_id":"6a7d7b710636ba417e41bd25","lab_id":"69ad52a3de79e566650fb289","country":"PL","accr_number":"AB 511","accr_body":"PCA","test_object":"Inne przetwory naftowe - kondensat naftowy","methodology":"Zawartość wody","parameters":[{"name":"Zakres","range":"(0,003 – 0,100) %(m/m)"}],"technique":"Metoda miareczkowania kulometrycznego","techniques":["Metoda miareczkowania kulometrycznego"],"computed":[],"activity":"Zawartość wody\nZakres (0,003 – 0,100) %(m/m)\nMetoda miareczkowania kulometrycznego","reference":"PN-EN ISO 12937:2005 z wyłączeniem punktu 6.2 | PN-EN ISO 12937:2005/Ap1:2021-11","norm_bases":["PN-EN ISO 12937:2005 z wyłączeniem punktu 6.2","PN-EN ISO 12937:2005/Ap1:2021-11"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Inne przetwory naftowe - kondensat naftowy Zawartość wody\nZakres (0,003 – 0,100) %(m/m)\nMetoda miareczkowania kulometrycznego PN-EN ISO 12937:2005 z wyłączeniem punktu 6.2 | PN-EN ISO 12937:2005/Ap1:2021-11 Inne przetwory naftowe - kondensat naftowy Zawartosc wody\nZakres (0,003 – 0,100) %(m/m)\nMetoda miareczkowania kulometrycznego PN-EN ISO 12937:2005 z wylaczeniem punktu 6.2 | PN-EN ISO 12937:2005/Ap1:2021-11","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Water content","parameters_en":[{"name":"Range","range":"(0,003 – 0,100) %(m/m)"}],"search_en":"Other petroleum products - petroleum condensate Water content Coulometric titration method Laboratory Range PN-EN ISO 12937:2005 z wyłączeniem punktu 6.2 | PN-EN ISO 12937:2005/Ap1:2021-11","technique_en":"Coulometric titration method","test_object_en":"Other petroleum products - petroleum condensate","lab_section_zh":"实验室","methodology_zh":"水分含量","parameters_zh":[{"name":"范围","range":"(0,003 – 0,100) %(m/m)"}],"search_zh":"水分含量 库仑滴定法 实验室 范围 PN-EN ISO 12937:2005 z wyłączeniem punktu 6.2 | PN-EN ISO 12937:2005/Ap1:2021-11","technique_zh":"库仑滴定法"},{"_id":"6a7d7b710636ba417e41bd26","lab_id":"69ad52a3de79e566650fb289","country":"PL","accr_number":"AB 511","accr_body":"PCA","test_object":"Paliwa gazowe - gaz ziemny","methodology":"Zawartość","parameters":[{"name":"C1","range":"(30,00 - 100,0) %mol"},{"name":"C2","range":"(0,1000 - 15,00) %mol"},{"name":"C3","range":"(0,0100 – 7,000) %mol"},{"name":"i-C4","range":"(0,0010 - 1,000) %mol"},{"name":"n-C4","range":"(0,0010 - 1,000) %mol"},{"name":"i-C5, n-C5","range":"(0,0010 - 0,5000) %mol"},{"name":"neoC5, ΣC6, ΣC7, ΣC8","range":"(0,0010 - 0,1000) %mol"},{"name":"CO2","range":"(0,0100 – 1,000) %mol"},{"name":"N2","range":"(1,000 - 65,00) %mol"},{"name":"He","range":"(0,0100 – 0,6000) %mol"},{"name":"H2","range":"(0,0010 - 0,1000) %mol"}],"technique":"Metoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD) i płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD) i płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość\nZakres:\nC1 (30,00 - 100,0) %mol\nC2 (0,1000 - 15,00) %mol\nC3 (0,0100 – 7,000) %mol\ni-C4 (0,0010 - 1,000) %mol\nn-C4 (0,0010 - 1,000) %mol\ni-C5, n-C5 (0,0010 - 0,5000) %mol\nneoC5, ΣC6, ΣC7, ΣC8 (0,0010 - 0,1000) %mol\nCO2 (0,0100 – 1,000) %mol\nN2 (1,000 - 65,00) %mol\nHe (0,0100 – 0,6000) %mol\nH2 (0,0010 - 0,1000) %mol\nMetoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD) i płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN ISO 6974-1:2012","norm_bases":["PN-EN ISO 6974-1:2012"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe - gaz ziemny Zawartość\nZakres:\nC1 (30,00 - 100,0) %mol\nC2 (0,1000 - 15,00) %mol\nC3 (0,0100 – 7,000) %mol\ni-C4 (0,0010 - 1,000) %mol\nn-C4 (0,0010 - 1,000) %mol\ni-C5, n-C5 (0,0010 - 0,5000) %mol\nneoC5, ΣC6, ΣC7, ΣC8 (0,0010 - 0,1000) %mol\nCO2 (0,0100 – 1,000) %mol\nN2 (1,000 - 65,00) %mol\nHe (0,0100 – 0,6000) %mol\nH2 (0,0010 - 0,1000) %mol\nMetoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD) i płomieniowo-jonizacyjną (GC-FID) PN-EN ISO 6974-1:2012 Paliwa gazowe - gaz ziemny Zawartosc\nZakres:\nC1 (30,00 - 100,0) %mol\nC2 (0,1000 - 15,00) %mol\nC3 (0,0100 – 7,000) %mol\ni-C4 (0,0010 - 1,000) %mol\nn-C4 (0,0010 - 1,000) %mol\ni-C5, n-C5 (0,0010 - 0,5000) %mol\nneoC5, ΣC6, ΣC7, ΣC8 (0,0010 - 0,1000) %mol\nCO2 (0,0100 – 1,000) %mol\nN2 (1,000 - 65,00) %mol\nHe (0,0100 – 0,6000) %mol\nH2 (0,0010 - 0,1000) %mol\nMetoda chromatografii gazowej z detekcja termokonduktometryczna (GC-TCD) i plomieniowo-jonizacyjna (GC-FID) PN-EN ISO 6974-1:2012","categories":["petro"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Content","parameters_en":[{"name":"C1","range":"(30,00 - 100,0) %mol"},{"name":"C2","range":"(0,1000 - 15,00) %mol"},{"name":"C3","range":"(0,0100 – 7,000) %mol"},{"name":"i-C4","range":"(0,0010 - 1,000) %mol"},{"name":"n-C4","range":"(0,0010 - 1,000) %mol"},{"name":"i-C5, n-C5","range":"(0,0010 - 0,5000) %mol"},{"name":"neoC5, ΣC6, ΣC7, ΣC8","range":"(0,0010 - 0,1000) %mol"},{"name":"CO2","range":"(0,0100 – 1,000) %mol"},{"name":"N2","range":"(1,000 - 65,00) %mol"},{"name":"He","range":"(0,0100 – 0,6000) %mol"},{"name":"H2","range":"(0,0010 - 0,1000) %mol"}],"search_en":"Gaseous fuels - natural gas Content Gas chromatography with thermal conductivity detection (GC-TCD) and flame ionization detection (GC-FID) Laboratory C1 C2 C3 i-C4 n-C4 i-C5, n-C5 neoC5, ΣC6, ΣC7, ΣC8 CO2 N2 He H2 PN-EN ISO 6974-1:2012","technique_en":"Gas chromatography with thermal conductivity detection (GC-TCD) and flame ionization detection (GC-FID)","test_object_en":"Gaseous fuels - natural gas","lab_section_zh":"实验室","search_zh":"含量 实验室 CO2 PN-EN ISO 6974-1:2012","parameters_zh":[{"name":"C1","range":"(30,00 - 100,0) %mol"},{"name":"C2","range":"(0,1000 - 15,00) %mol"},{"name":"C3","range":"(0,0100 – 7,000) %mol"},{"name":"i-C4","range":"(0,0010 - 1,000) %mol"},{"name":"n-C4","range":"(0,0010 - 1,000) %mol"},{"name":"i-C5, n-C5","range":"(0,0010 - 0,5000) %mol"},{"name":"neoC5, ΣC6, ΣC7, ΣC8","range":"(0,0010 - 0,1000) %mol"},{"name":"CO2","range":"(0,0100 – 1,000) %mol"},{"name":"N2","range":"(1,000 - 65,00) %mol"},{"name":"He","range":"(0,0100 – 0,6000) %mol"},{"name":"H2","range":"(0,0010 - 0,1000) %mol"}],"methodology_zh":"含量"},{"_id":"6a7d7b710636ba417e41bd27","lab_id":"69ad52a3de79e566650fb289","country":"PL","accr_number":"AB 511","accr_body":"PCA","test_object":"Paliwa gazowe - gaz ziemny","methodology":"Ciepło spalania, wartość opałowa, gęstość i gęstość względna, liczba Wobbego obliczone na podstawie składu gazu i zakresu wymienionego powyżej (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ciepło spalania, wartość opałowa, gęstość i gęstość względna, liczba Wobbego obliczone na podstawie składu gazu i zakresu wymienionego powyżej (z obliczeń)","reference":"PN-EN ISO 6976:2016-11","norm_bases":["PN-EN ISO 6976:2016-11"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe - gaz ziemny Ciepło spalania, wartość opałowa, gęstość i gęstość względna, liczba Wobbego obliczone na podstawie składu gazu i zakresu wymienionego powyżej (z obliczeń) PN-EN ISO 6976:2016-11 Paliwa gazowe - gaz ziemny Cieplo spalania, wartosc opalowa, gestosc i gestosc wzgledna, liczba Wobbego obliczone na podstawie skladu gazu i zakresu wymienionego powyzej (z obliczen) PN-EN ISO 6976:2016-11","categories":["petro"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Gross calorific value, net calorific value, density and relative density, Wobbe index calculated from the gas composition and the range listed above (calculated)","search_en":"Gaseous fuels - natural gas Gross calorific value, net calorific value, density and relative density, Wobbe index calculated from the gas composition and the range listed above (calculated) Laboratory PN-EN ISO 6976:2016-11","test_object_en":"Gaseous fuels - natural gas","lab_section_zh":"实验室","search_zh":"实验室 PN-EN ISO 6976:2016-11"},{"_id":"6a7d7b710636ba417e41bd28","lab_id":"69ad52a3de79e566650fb289","country":"PL","accr_number":"AB 511","accr_body":"PCA","test_object":"Paliwa gazowe - gaz ziemny","methodology":"Pobieranie próbek jednostkowych do badań chromatograficznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek jednostkowych do badań chromatograficznych","reference":"PN-EN ISO 10715:2023-03 pkt 7.2.2","norm_bases":["PN-EN ISO 10715:2023-03 pkt 7.2.2"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe - gaz ziemny Pobieranie próbek jednostkowych do badań chromatograficznych PN-EN ISO 10715:2023-03 pkt 7.2.2 Paliwa gazowe - gaz ziemny Pobieranie probek jednostkowych do badan chromatograficznych PN-EN ISO 10715:2023-03 pkt 7.2.2","categories":["petro"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Sampling of individual samples for chromatographic testing","search_en":"Gaseous fuels - natural gas Sampling of individual samples for chromatographic testing Laboratory PN-EN ISO 10715:2023-03 pkt 7.2.2","test_object_en":"Gaseous fuels - natural gas","lab_section_zh":"实验室","search_zh":"实验室 PN-EN ISO 10715:2023-03 pkt 7.2.2"}],"has_pdf":true}