{"lab":{"_id":"69ad52a3de79e566650fb281","accr_number":"AB 506","country":"PL","accr_body":"PCA","address":"ul. Złota 59, 00-120 Warszawa, PGE ENERGIA CIEPŁA S.A. Oddział w Krakowie, ul. Ciepłownicza 1","categories":["water","petro","environment"],"city":"Warszawa","imported_at":"2026-03-08T10:42:43.265Z","methods_count":36,"name":"PGE ENERGIA CIEPŁA S.A.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_506.pdf"],"scope_summary":"","search_text":"pge energia ciepła s.a. ul. złota 59, 00-120 warszawa, pge energia ciepła s.a. oddział w krakowie, ul. ciepłownicza 1 petro other materials pharma environment water electronics","status":"active","updated_at":"2026-03-08T14:51:21.642Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-17T20:34:07.477Z","location":{"type":"Point","coordinates":[21.0122,52.2297]},"email_confidence":"high","email_mx":true,"email_source":"https://www.pca.gov.pl/akredytowane-podmioty/akredytacje-aktywne/laboratoria-badawcze/AB%20506,plik.html","fields_of_testing":[{"codes":"C/10/P; C/28/P; C/30/P","pl":"Badania chemiczne i pobieranie próbek paliw stałych, wody, ścieków","en":"Chemical tests and sampling of soild fuels, water, sewage"},{"codes":"C/32","pl":"Badania chemiczne odpadów","en":"Chemical tests of waste"},{"codes":"N/10/P; N/28/P; N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek paliw stałych, wody, ścieków","en":"Tests of physical properties and sampling of solid fuels, water, sewage"},{"codes":"N/32","pl":"Badania właściwości fizycznych odpadów","en":"Tests of physical properties of waste"}],"issue":{"no":"26","date":"22.06.2026"},"parse_date":"2026-08-17T20:34:07.477Z","parse_source":"agent-claude-code","map_coord":[52.230071,21.002445],"map_geo":"nominatim-street","lab_locations":[{"name":"Wydział Laboratorium","address":"ul. Ciepłownicza 1","city":"Kraków","postal":"31-587"}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/d6e6c4e936b1d3eb811865762af33beb/AB%20506.pdf","has_en":true,"category_counts":{"water":19,"petro":15,"environment":2,"materials":1},"category_scores":{"water":9.76,"petro":6.08,"environment":0.11,"materials":0.03},"has_zh":true},"methods":[{"_id":"6a83703faf14b9c0e7b1ee4d","lab_id":"69ad52a3de79e566650fb281","country":"PL","accr_number":"AB 506","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-G-04502:2014-11 pkt 5.3.1.4","norm_bases":["PN-G-04502:2014-11 pkt 5.3.1.4"],"lab_section":"Wydział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Pobieranie próbek do badań chemicznych i fizycznych PN-G-04502:2014-11 pkt 5.3.1.4 Paliwa stale: wegiel kamienny Pobieranie probek do badan chemicznych i fizycznych PN-G-04502:2014-11 pkt 5.3.1.4","categories":["petro"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Solid fuels: hard coal Sampling for chemical and physical testing PN-G-04502:2014-11 pkt 5.3.1.4","test_object_en":"Solid fuels: hard coal","methodology_zh":"化学与物理检测用样品采集","search_zh":"固体燃料：烟煤 化学与物理检测用样品采集 PN-G-04502:2014-11 pkt 5.3.1.4","test_object_zh":"固体燃料：烟煤"},{"_id":"6a83703faf14b9c0e7b1ee4e","lab_id":"69ad52a3de79e566650fb281","country":"PL","accr_number":"AB 506","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Ciepło spalania","parameters":[{"name":"Zakres","range":"(13956 – 34890) kJ/kg"}],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna"],"computed":[],"activity":"Ciepło spalania\nZakres (13956 – 34890) kJ/kg\nMetoda kalorymetryczna","reference":"PN-ISO 1928:2020-05 | PN-81/G-04513","norm_bases":["PN-ISO 1928:2020-05","PN-81/G-04513"],"lab_section":"Wydział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Ciepło spalania\nZakres (13956 – 34890) kJ/kg\nMetoda kalorymetryczna PN-ISO 1928:2020-05 | PN-81/G-04513 Paliwa stale: wegiel kamienny Cieplo spalania\nZakres (13956 – 34890) kJ/kg\nMetoda kalorymetryczna PN-ISO 1928:2020-05 | PN-81/G-04513","categories":["petro"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gross calorific value","parameters_en":[{"name":"Range","range":"(13956 – 34890) kJ/kg"}],"search_en":"Solid fuels: hard coal Gross calorific value Calorimetric method Range PN-ISO 1928:2020-05 | PN-81/G-04513","technique_en":"Calorimetric method","test_object_en":"Solid fuels: hard coal","methodology_zh":"高位发热量","parameters_zh":[{"name":"范围","range":"(13956 – 34890) kJ/kg"}],"search_zh":"固体燃料：烟煤 高位发热量 量热法 范围 PN-ISO 1928:2020-05 | PN-81/G-04513","technique_zh":"量热法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a83703faf14b9c0e7b1ee4f","lab_id":"69ad52a3de79e566650fb281","country":"PL","accr_number":"AB 506","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Wartość opałowa (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wartość opałowa (z obliczeń)","reference":"PN-ISO 1928:2020-05 | PN-81/G-04513","norm_bases":["PN-ISO 1928:2020-05","PN-81/G-04513"],"lab_section":"Wydział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Wartość opałowa (z obliczeń) PN-ISO 1928:2020-05 | PN-81/G-04513 Paliwa stale: wegiel kamienny Wartosc opalowa (z obliczen) PN-ISO 1928:2020-05 | PN-81/G-04513","categories":["petro"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Net calorific value (calculated)","search_en":"Solid fuels: hard coal Net calorific value (calculated) PN-ISO 1928:2020-05 | PN-81/G-04513","test_object_en":"Solid fuels: hard coal","methodology_zh":"低位发热量（计算值）","search_zh":"固体燃料：烟煤 低位发热量（计算值） PN-ISO 1928:2020-05 | PN-81/G-04513","test_object_zh":"固体燃料：烟煤"},{"_id":"6a83703faf14b9c0e7b1ee50","lab_id":"69ad52a3de79e566650fb281","country":"PL","accr_number":"AB 506","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość siarki całkowitej","parameters":[{"name":"Zakres","range":"(0,10 – 2,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość siarki całkowitej\nZakres (0,10 – 2,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"ISO 19579:2006 | PN-G-04584:2001","norm_bases":["ISO 19579:2006","PN-G-04584:2001"],"lab_section":"Wydział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość siarki całkowitej\nZakres (0,10 – 2,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR ISO 19579:2006 | PN-G-04584:2001 Paliwa stale: wegiel kamienny Zawartosc siarki calkowitej\nZakres (0,10 – 2,00) %\nMetoda wysokotemperaturowego spalania z detekcja IR ISO 19579:2006 | PN-G-04584:2001","categories":["petro"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total sulfur content","parameters_en":[{"name":"Range","range":"(0,10 – 2,00) %"}],"search_en":"Solid fuels: hard coal Total sulfur content High-temperature combustion with IR detection Range ISO 19579:2006 | PN-G-04584:2001","technique_en":"High-temperature combustion with IR detection","test_object_en":"Solid fuels: hard coal","methodology_zh":"全硫含量","parameters_zh":[{"name":"范围","range":"(0,10 – 2,00) %"}],"search_zh":"固体燃料：烟煤 全硫含量 高温燃烧红外检测法 范围 ISO 19579:2006 | PN-G-04584:2001","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a83703faf14b9c0e7b1ee51","lab_id":"69ad52a3de79e566650fb281","country":"PL","accr_number":"AB 506","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość popiołu","parameters":[{"name":"Zakres","range":"(8,0 – 50,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość popiołu\nZakres (8,0 – 50,0) %\nMetoda wagowa","reference":"PN-ISO 1171:2002 | PN-80/G-04512+Az1:2002 pkt 2.4.1","norm_bases":["PN-ISO 1171:2002","PN-80/G-04512+Az1:2002 pkt 2.4.1"],"lab_section":"Wydział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość popiołu\nZakres (8,0 – 50,0) %\nMetoda wagowa PN-ISO 1171:2002 | PN-80/G-04512+Az1:2002 pkt 2.4.1 Paliwa stale: wegiel kamienny Zawartosc popiolu\nZakres (8,0 – 50,0) %\nMetoda wagowa PN-ISO 1171:2002 | PN-80/G-04512+Az1:2002 pkt 2.4.1","categories":["petro"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ash content","parameters_en":[{"name":"Range","range":"(8,0 – 50,0) %"}],"search_en":"Solid fuels: hard coal Ash content Gravimetric method Range PN-ISO 1171:2002 | PN-80/G-04512+Az1:2002 pkt 2.4.1","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(8,0 – 50,0) %"}],"search_zh":"固体燃料：烟煤 灰分含量 重量法 范围 PN-ISO 1171:2002 | PN-80/G-04512+Az1:2002 pkt 2.4.1","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a83703faf14b9c0e7b1ee52","lab_id":"69ad52a3de79e566650fb281","country":"PL","accr_number":"AB 506","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wilgoci całkowitej (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość wilgoci całkowitej (z obliczeń)","reference":"PN-ISO 589:2006 (metoda A) | PN-80/G-04511","norm_bases":["PN-ISO 589:2006 (metoda A)","PN-80/G-04511"],"lab_section":"Wydział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci całkowitej (z obliczeń) PN-ISO 589:2006 (metoda A) | PN-80/G-04511 Paliwa stale: wegiel kamienny Zawartosc wilgoci calkowitej (z obliczen) PN-ISO 589:2006 (metoda A) | PN-80/G-04511","categories":["petro"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total moisture content (calculated)","search_en":"Solid fuels: hard coal Total moisture content (calculated) PN-ISO 589:2006 (metoda A) | PN-80/G-04511","test_object_en":"Solid fuels: hard coal","search_zh":"固体燃料：烟煤 全水分含量（计算值） PN-ISO 589:2006 (metoda A) | PN-80/G-04511","test_object_zh":"固体燃料：烟煤","methodology_zh":"全水分含量（计算值）"},{"_id":"6a83703faf14b9c0e7b1ee53","lab_id":"69ad52a3de79e566650fb281","country":"PL","accr_number":"AB 506","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wilgoci pierwszego stopnia (wilgoci przemijającej).","parameters":[{"name":"Zakres","range":"(1,0 – 20,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci pierwszego stopnia (wilgoci przemijającej).\nZakres (1,0 – 20,0) %\nMetoda wagowa","reference":"PN-ISO 589:2006 | PN-80/G-04511","norm_bases":["PN-ISO 589:2006","PN-80/G-04511"],"lab_section":"Wydział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci pierwszego stopnia (wilgoci przemijającej).\nZakres (1,0 – 20,0) %\nMetoda wagowa PN-ISO 589:2006 | PN-80/G-04511 Paliwa stale: wegiel kamienny Zawartosc wilgoci pierwszego stopnia (wilgoci przemijajacej).\nZakres (1,0 – 20,0) %\nMetoda wagowa PN-ISO 589:2006 | PN-80/G-04511","categories":["petro"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"First-stage moisture content (transient moisture).","parameters_en":[{"name":"Range","range":"(1,0 – 20,0) %"}],"search_en":"Solid fuels: hard coal First-stage moisture content (transient moisture). Gravimetric method Range PN-ISO 589:2006 | PN-80/G-04511","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","parameters_zh":[{"name":"范围","range":"(1,0 – 20,0) %"}],"search_zh":"固体燃料：烟煤 重量法 范围 PN-ISO 589:2006 | PN-80/G-04511","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a83703faf14b9c0e7b1ee54","lab_id":"69ad52a3de79e566650fb281","country":"PL","accr_number":"AB 506","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wilgoci w próbce analitycznej","parameters":[{"name":"Zakres","range":"(0,8 – 15,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (0,8 – 15,0) %\nMetoda wagowa","reference":"PN-ISO 11722:2009 | PN-80/G-04511","norm_bases":["PN-ISO 11722:2009","PN-80/G-04511"],"lab_section":"Wydział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci w próbce analitycznej\nZakres (0,8 – 15,0) %\nMetoda wagowa PN-ISO 11722:2009 | PN-80/G-04511 Paliwa stale: wegiel kamienny Zawartosc wilgoci w probce analitycznej\nZakres (0,8 – 15,0) %\nMetoda wagowa PN-ISO 11722:2009 | PN-80/G-04511","categories":["petro"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Moisture content in the analytical sample","parameters_en":[{"name":"Range","range":"(0,8 – 15,0) %"}],"search_en":"Solid fuels: hard coal Moisture content in the analytical sample Gravimetric method Range PN-ISO 11722:2009 | PN-80/G-04511","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(0,8 – 15,0) %"}],"search_zh":"固体燃料：烟煤 分析样品水分含量 重量法 范围 PN-ISO 11722:2009 | PN-80/G-04511","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a83703faf14b9c0e7b1ee55","lab_id":"69ad52a3de79e566650fb281","country":"PL","accr_number":"AB 506","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wilgoci drugiego stopnia (wilgoci w węglu powietrzno-suchym)","parameters":[{"name":"Zakres","range":"(0,8 – 15,0)%"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci drugiego stopnia (wilgoci w węglu powietrzno-suchym)\nZakres (0,8 – 15,0)%\nMetoda wagowa","reference":"PN-ISO 589:2006 (metoda A1) | PN-80/G-04511","norm_bases":["PN-ISO 589:2006 (metoda A1)","PN-80/G-04511"],"lab_section":"Wydział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci drugiego stopnia (wilgoci w węglu powietrzno-suchym)\nZakres (0,8 – 15,0)%\nMetoda wagowa PN-ISO 589:2006 (metoda A1) | PN-80/G-04511 Paliwa stale: wegiel kamienny Zawartosc wilgoci drugiego stopnia (wilgoci w weglu powietrzno-suchym)\nZakres (0,8 – 15,0)%\nMetoda wagowa PN-ISO 589:2006 (metoda A1) | PN-80/G-04511","categories":["petro"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Second-stage moisture content (moisture in air-dried coal)","parameters_en":[{"name":"Range","range":"(0,8 – 15,0)%"}],"search_en":"Solid fuels: hard coal Second-stage moisture content (moisture in air-dried coal) Gravimetric method Range PN-ISO 589:2006 (metoda A1) | PN-80/G-04511","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","parameters_zh":[{"name":"范围","range":"(0,8 – 15,0)%"}],"search_zh":"固体燃料：烟煤 重量法 范围 PN-ISO 589:2006 (metoda A1) | PN-80/G-04511","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a83703faf14b9c0e7b1ee56","lab_id":"69ad52a3de79e566650fb281","country":"PL","accr_number":"AB 506","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość węgla całkowitego","parameters":[{"name":"Zakres","range":"(30,0 – 80,0) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość węgla całkowitego\nZakres (30,0 – 80,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04571:1998","norm_bases":["PN-G-04571:1998"],"lab_section":"Wydział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość węgla całkowitego\nZakres (30,0 – 80,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04571:1998 Paliwa stale: wegiel kamienny Zawartosc wegla calkowitego\nZakres (30,0 – 80,0) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04571:1998","categories":["petro"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total carbon content","parameters_en":[{"name":"Range","range":"(30,0 – 80,0) %"}],"search_en":"Solid fuels: hard coal Total carbon content High-temperature combustion with IR detection Range PN-G-04571:1998","technique_en":"High-temperature combustion with IR detection","test_object_en":"Solid fuels: hard coal","methodology_zh":"总碳含量","parameters_zh":[{"name":"范围","range":"(30,0 – 80,0) %"}],"search_zh":"固体燃料：烟煤 总碳含量 高温燃烧红外检测法 范围 PN-G-04571:1998","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a83703faf14b9c0e7b1ee57","lab_id":"69ad52a3de79e566650fb281","country":"PL","accr_number":"AB 506","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wodoru całkowitego","parameters":[{"name":"Zakres","range":"(3,00 – 6,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość wodoru całkowitego\nZakres (3,00 – 6,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04571:1998","norm_bases":["PN-G-04571:1998"],"lab_section":"Wydział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wodoru całkowitego\nZakres (3,00 – 6,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04571:1998 Paliwa stale: wegiel kamienny Zawartosc wodoru calkowitego\nZakres (3,00 – 6,00) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04571:1998","categories":["petro"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total hydrogen content","parameters_en":[{"name":"Range","range":"(3,00 – 6,00) %"}],"search_en":"Solid fuels: hard coal Total hydrogen content High-temperature combustion with IR detection Range PN-G-04571:1998","technique_en":"High-temperature combustion with IR detection","test_object_en":"Solid fuels: hard coal","parameters_zh":[{"name":"范围","range":"(3,00 – 6,00) %"}],"search_zh":"固体燃料：烟煤 全氢含量 高温燃烧红外检测法 范围 PN-G-04571:1998","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：烟煤","methodology_zh":"全氢含量"},{"_id":"6a83703faf14b9c0e7b1ee58","lab_id":"69ad52a3de79e566650fb281","country":"PL","accr_number":"AB 506","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wilgoci w próbce analitycznej","parameters":[{"name":"Zakres","range":"(0,10 – 15,00) %"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (0,10 – 15,00) %\nMetoda termograwimetryczna (TGA)","reference":"PN-G-04560:1998","norm_bases":["PN-G-04560:1998"],"lab_section":"Wydział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci w próbce analitycznej\nZakres (0,10 – 15,00) %\nMetoda termograwimetryczna (TGA) PN-G-04560:1998 Paliwa stale: wegiel kamienny Zawartosc wilgoci w probce analitycznej\nZakres (0,10 – 15,00) %\nMetoda termograwimetryczna (TGA) PN-G-04560:1998","categories":["petro"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Moisture content in the analytical sample","parameters_en":[{"name":"Range","range":"(0,10 – 15,00) %"}],"search_en":"Solid fuels: hard coal Moisture content in the analytical sample Thermogravimetric method (TGA) Range PN-G-04560:1998","technique_en":"Thermogravimetric method (TGA)","test_object_en":"Solid fuels: hard coal","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(0,10 – 15,00) %"}],"search_zh":"固体燃料：烟煤 分析样品水分含量 热重法（TGA） 范围 PN-G-04560:1998","technique_zh":"热重法（TGA）","test_object_zh":"固体燃料：烟煤"},{"_id":"6a83703faf14b9c0e7b1ee59","lab_id":"69ad52a3de79e566650fb281","country":"PL","accr_number":"AB 506","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość popiołu","parameters":[{"name":"Zakres","range":"(8,00 – 50,00) %"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)"],"computed":[],"activity":"Zawartość popiołu\nZakres (8,00 – 50,00) %\nMetoda termograwimetryczna (TGA)","reference":"PN-G-04560:1998","norm_bases":["PN-G-04560:1998"],"lab_section":"Wydział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość popiołu\nZakres (8,00 – 50,00) %\nMetoda termograwimetryczna (TGA) PN-G-04560:1998 Paliwa stale: wegiel kamienny Zawartosc popiolu\nZakres (8,00 – 50,00) %\nMetoda termograwimetryczna (TGA) PN-G-04560:1998","categories":["petro"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ash content","parameters_en":[{"name":"Range","range":"(8,00 – 50,00) %"}],"search_en":"Solid fuels: hard coal Ash content Thermogravimetric method (TGA) Range PN-G-04560:1998","technique_en":"Thermogravimetric method (TGA)","test_object_en":"Solid fuels: hard coal","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(8,00 – 50,00) %"}],"search_zh":"固体燃料：烟煤 灰分含量 热重法（TGA） 范围 PN-G-04560:1998","technique_zh":"热重法（TGA）","test_object_zh":"固体燃料：烟煤"},{"_id":"6a83703faf14b9c0e7b1ee5a","lab_id":"69ad52a3de79e566650fb281","country":"PL","accr_number":"AB 506","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość części lotnych","parameters":[{"name":"Zakres","range":"(20,00 – 35,00) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość części lotnych\nZakres (20,00 – 35,00) %\nMetoda wagowa","reference":"PN-G-04516:1998","norm_bases":["PN-G-04516:1998"],"lab_section":"Wydział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość części lotnych\nZakres (20,00 – 35,00) %\nMetoda wagowa PN-G-04516:1998 Paliwa stale: wegiel kamienny Zawartosc czesci lotnych\nZakres (20,00 – 35,00) %\nMetoda wagowa PN-G-04516:1998","categories":["petro"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Volatile matter content","parameters_en":[{"name":"Range","range":"(20,00 – 35,00) %"}],"search_en":"Solid fuels: hard coal Volatile matter content Gravimetric method Range PN-G-04516:1998","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","parameters_zh":[{"name":"范围","range":"(20,00 – 35,00) %"}],"search_zh":"固体燃料：烟煤 挥发分含量 重量法 范围 PN-G-04516:1998","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤","methodology_zh":"挥发分含量"},{"_id":"6a83703faf14b9c0e7b1ee5b","lab_id":"69ad52a3de79e566650fb281","country":"PL","accr_number":"AB 506","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Wskaźnik fixed carbon (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik fixed carbon (z obliczeń)","reference":"PN-G-04516:1998","norm_bases":["PN-G-04516:1998"],"lab_section":"Wydział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Wskaźnik fixed carbon (z obliczeń) PN-G-04516:1998 Paliwa stale: wegiel kamienny Wskaznik fixed carbon (z obliczen) PN-G-04516:1998","categories":["petro"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fixed carbon index (calculated)","search_en":"Solid fuels: hard coal Fixed carbon index (calculated) PN-G-04516:1998","test_object_en":"Solid fuels: hard coal","search_zh":"固体燃料：烟煤 固定碳指标（由计算得出） PN-G-04516:1998","test_object_zh":"固体燃料：烟煤","methodology_zh":"固定碳指标（由计算得出）"},{"_id":"6a83703faf14b9c0e7b1ee5c","lab_id":"69ad52a3de79e566650fb281","country":"PL","accr_number":"AB 506","accr_body":"PCA","test_object":"Odpady O) kod: 10 01 01, 10 01 02, 10 01 80","methodology":"Zawartość węgla całkowitego","parameters":[{"name":"Zakres","range":"(1,0 – 50,0) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość węgla całkowitego\nZakres (1,0 – 50,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04571:1998","norm_bases":["PN-G-04571:1998"],"lab_section":"Wydział Laboratorium","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Odpady O) kod: 10 01 01, 10 01 02, 10 01 80 Zawartość węgla całkowitego\nZakres (1,0 – 50,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04571:1998 Odpady O) kod: 10 01 01, 10 01 02, 10 01 80 Zawartosc wegla calkowitego\nZakres (1,0 – 50,0) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04571:1998","categories":["environment"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total carbon content","parameters_en":[{"name":"Range","range":"(1,0 – 50,0) %"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue","search_en":"Waste O) code: 10 01 01, 10 01 02, 10 01 80 Total carbon content High-temperature combustion with IR detection waste codes according to the Regulation of the Minister of Climate on the waste catalogue Range PN-G-04571:1998","technique_en":"High-temperature combustion with IR detection","test_object_en":"Waste O) code: 10 01 01, 10 01 02, 10 01 80","methodology_zh":"总碳含量","parameters_zh":[{"name":"范围","range":"(1,0 – 50,0) %"}],"search_zh":"总碳含量 高温燃烧红外检测法 废物代码依据气候部长关于废物名录的条例 范围 PN-G-04571:1998","technique_zh":"高温燃烧红外检测法","regulatory_area_zh":"废物代码依据气候部长关于废物名录的条例"},{"_id":"6a83703faf14b9c0e7b1ee5d","lab_id":"69ad52a3de79e566650fb281","country":"PL","accr_number":"AB 506","accr_body":"PCA","test_object":"Odpady O) kod: 10 01 01, 10 01 02, 10 01 80","methodology":"Zawartość wilgoci w próbce analitycznej","parameters":[{"name":"Zakres","range":"(0,1 – 10,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (0,1 – 10,0) %\nMetoda wagowa","reference":"PN-80/G-04511","norm_bases":["PN-80/G-04511"],"lab_section":"Wydział Laboratorium","lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Odpady O) kod: 10 01 01, 10 01 02, 10 01 80 Zawartość wilgoci w próbce analitycznej\nZakres (0,1 – 10,0) %\nMetoda wagowa PN-80/G-04511 Odpady O) kod: 10 01 01, 10 01 02, 10 01 80 Zawartosc wilgoci w probce analitycznej\nZakres (0,1 – 10,0) %\nMetoda wagowa PN-80/G-04511","categories":["environment"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Moisture content in the analytical sample","parameters_en":[{"name":"Range","range":"(0,1 – 10,0) %"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue","search_en":"Waste O) code: 10 01 01, 10 01 02, 10 01 80 Moisture content in the analytical sample Gravimetric method waste codes according to the Regulation of the Minister of Climate on the waste catalogue Range PN-80/G-04511","technique_en":"Gravimetric method","test_object_en":"Waste O) code: 10 01 01, 10 01 02, 10 01 80","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(0,1 – 10,0) %"}],"search_zh":"分析样品水分含量 重量法 废物代码依据气候部长关于废物名录的条例 范围 PN-80/G-04511","technique_zh":"重量法","regulatory_area_zh":"废物代码依据气候部长关于废物名录的条例"},{"_id":"6a83703faf14b9c0e7b1ee5e","lab_id":"69ad52a3de79e566650fb281","country":"PL","accr_number":"AB 506","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":"Metoda manualna; Metoda automatyczna","techniques":["Metoda manualna","Metoda automatyczna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":"Wydział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 Scieki Pobieranie probek do badan chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Wastewater Sampling for chemical and physical testing Manual method; Automatic method PN-ISO 5667-10:2021-11","technique_en":"Manual method; Automatic method","test_object_en":"Wastewater","methodology_zh":"化学与物理检测用样品采集","search_zh":"污水 化学与物理检测用样品采集 手动法；自动法 PN-ISO 5667-10:2021-11","technique_zh":"手动法；自动法","test_object_zh":"污水"},{"_id":"6a83703faf14b9c0e7b1ee5f","lab_id":"69ad52a3de79e566650fb281","country":"PL","accr_number":"AB 506","accr_body":"PCA","test_object":"Ścieki","methodology":"Temperatura","parameters":[{"name":"Zakres","range":"(1,0 – 50,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura\nZakres (1,0 – 50,0) °C","reference":"PN/77/C-04584","norm_bases":["PN/77/C-04584"],"lab_section":"Wydział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Temperatura\nZakres (1,0 – 50,0) °C PN/77/C-04584 Scieki Temperatura\nZakres (1,0 – 50,0) °C PN/77/C-04584","categories":["water"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Temperature","parameters_en":[{"name":"Range","range":"(1,0 – 50,0) °C"}],"search_en":"Wastewater Temperature Range PN/77/C-04584","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(1,0 – 50,0) °C"}],"search_zh":"污水 温度 范围 PN/77/C-04584","test_object_zh":"污水","methodology_zh":"温度"},{"_id":"6a83703faf14b9c0e7b1ee60","lab_id":"69ad52a3de79e566650fb281","country":"PL","accr_number":"AB 506","accr_body":"PCA","test_object":"Ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0 – 500) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 500) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Wydział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Zawiesiny ogólne\nZakres (2,0 – 500) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Scieki Zawiesiny ogolne\nZakres (2,0 – 500) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2,0 – 500) mg/l"}],"search_en":"Wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Wastewater","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 500) mg/l"}],"search_zh":"污水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"污水"},{"_id":"6a83703faf14b9c0e7b1ee61","lab_id":"69ad52a3de79e566650fb281","country":"PL","accr_number":"AB 506","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu ogólnego","parameters":[{"name":"Zakres","range":"(1,00 – 500) mg/l"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją chemiluminescencyjną","techniques":["Metoda wysokotemperaturowego spalania z detekcją chemiluminescencyjną"],"computed":[],"activity":"Stężenie azotu ogólnego\nZakres (1,00 – 500) mg/l\nMetoda wysokotemperaturowego spalania z detekcją chemiluminescencyjną","reference":"PN-EN ISO 20236:2025-05","norm_bases":["PN-EN ISO 20236:2025-05"],"lab_section":"Wydział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu ogólnego\nZakres (1,00 – 500) mg/l\nMetoda wysokotemperaturowego spalania z detekcją chemiluminescencyjną PN-EN ISO 20236:2025-05 Scieki Stezenie azotu ogolnego\nZakres (1,00 – 500) mg/l\nMetoda wysokotemperaturowego spalania z detekcja chemiluminescencyjna PN-EN ISO 20236:2025-05","categories":["water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total nitrogen concentration","parameters_en":[{"name":"Range","range":"(1,00 – 500) mg/l"}],"search_en":"Wastewater Total nitrogen concentration High-temperature combustion with chemiluminescence detection Range PN-EN ISO 20236:2025-05","technique_en":"High-temperature combustion with chemiluminescence detection","test_object_en":"Wastewater","methodology_zh":"总氮浓度","parameters_zh":[{"name":"范围","range":"(1,00 – 500) mg/l"}],"search_zh":"污水 总氮浓度 高温燃烧-化学发光检测法 范围 PN-EN ISO 20236:2025-05","test_object_zh":"污水","technique_zh":"高温燃烧-化学发光检测法"},{"_id":"6a83703faf14b9c0e7b1ee62","lab_id":"69ad52a3de79e566650fb281","country":"PL","accr_number":"AB 506","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie ogólnego węgla organicznego (OWO)","parameters":[{"name":"Zakres","range":"(1,00 – 500) mg/l"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Stężenie ogólnego węgla organicznego (OWO)\nZakres (1,00 – 500) mg/l\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN 1484:1999 | PN-EN ISO 20236:2025-05","norm_bases":["PN-EN 1484:1999","PN-EN ISO 20236:2025-05"],"lab_section":"Wydział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie ogólnego węgla organicznego (OWO)\nZakres (1,00 – 500) mg/l\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN 1484:1999 | PN-EN ISO 20236:2025-05 Scieki Stezenie ogolnego wegla organicznego (OWO)\nZakres (1,00 – 500) mg/l\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN 1484:1999 | PN-EN ISO 20236:2025-05","categories":["water"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total organic carbon concentration (TOC)","parameters_en":[{"name":"Range","range":"(1,00 – 500) mg/l"}],"search_en":"Wastewater Total organic carbon concentration (TOC) High-temperature combustion with IR detection Range PN-EN 1484:1999 | PN-EN ISO 20236:2025-05","technique_en":"High-temperature combustion with IR detection","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(1,00 – 500) mg/l"}],"search_zh":"污水 总有机碳浓度（TOC） 高温燃烧红外检测法 范围 PN-EN 1484:1999 | PN-EN ISO 20236:2025-05","technique_zh":"高温燃烧红外检测法","test_object_zh":"污水","methodology_zh":"总有机碳浓度（TOC）"},{"_id":"6a83703faf14b9c0e7b1ee63","lab_id":"69ad52a3de79e566650fb281","country":"PL","accr_number":"AB 506","accr_body":"PCA","test_object":"Woda","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.3; 7.5; 7.6; 8.2; 9.4","norm_bases":["PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.3; 7.5; 7.6; 8.2; 9.4"],"lab_section":"Wydział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.3; 7.5; 7.6; 8.2; 9.4 Woda Pobieranie probek do badan chemicznych i fizycznych PN-EN ISO 5667-6:2016-12 z wylaczeniem pkt 7.3; 7.5; 7.6; 8.2; 9.4","categories":["water"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Water Sampling for chemical and physical testing PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.3; 7.5; 7.6; 8.2; 9.4","test_object_en":"Water","methodology_zh":"化学与物理检测用样品采集","search_zh":"水 化学与物理检测用样品采集 PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.3; 7.5; 7.6; 8.2; 9.4","test_object_zh":"水"},{"_id":"6a83703faf14b9c0e7b1ee64","lab_id":"69ad52a3de79e566650fb281","country":"PL","accr_number":"AB 506","accr_body":"PCA","test_object":"Woda","methodology":"Temperatura","parameters":[{"name":"Zakres","range":"(1,0 – 50,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura\nZakres (1,0 – 50,0) °C","reference":"PN/77/C-04584","norm_bases":["PN/77/C-04584"],"lab_section":"Wydział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Temperatura\nZakres (1,0 – 50,0) °C PN/77/C-04584 Woda Temperatura\nZakres (1,0 – 50,0) °C PN/77/C-04584","categories":["water"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Temperature","parameters_en":[{"name":"Range","range":"(1,0 – 50,0) °C"}],"search_en":"Water Temperature Range PN/77/C-04584","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(1,0 – 50,0) °C"}],"search_zh":"水 温度 范围 PN/77/C-04584","test_object_zh":"水","methodology_zh":"温度"},{"_id":"6a83703faf14b9c0e7b1ee65","lab_id":"69ad52a3de79e566650fb281","country":"PL","accr_number":"AB 506","accr_body":"PCA","test_object":"Woda","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-11:2017-10 z wyłączeniem pkt 5.2; 6.1.2, 6.2, 6.3","norm_bases":["PN-ISO 5667-11:2017-10 z wyłączeniem pkt 5.2; 6.1.2, 6.2, 6.3"],"lab_section":"Wydział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-11:2017-10 z wyłączeniem pkt 5.2; 6.1.2, 6.2, 6.3 Woda Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-11:2017-10 z wylaczeniem pkt 5.2; 6.1.2, 6.2, 6.3","categories":["water"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Water Sampling for chemical and physical testing PN-ISO 5667-11:2017-10 z wyłączeniem pkt 5.2; 6.1.2, 6.2, 6.3","test_object_en":"Water","methodology_zh":"化学与物理检测用样品采集","search_zh":"水 化学与物理检测用样品采集 PN-ISO 5667-11:2017-10 z wyłączeniem pkt 5.2; 6.1.2, 6.2, 6.3","test_object_zh":"水"},{"_id":"6a83703faf14b9c0e7b1ee66","lab_id":"69ad52a3de79e566650fb281","country":"PL","accr_number":"AB 506","accr_body":"PCA","test_object":"Woda","methodology":"Temperatura","parameters":[{"name":"Zakres","range":"(1,0 – 50,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura\nZakres (1,0 – 50,0) °C","reference":"PN/77/C-04584","norm_bases":["PN/77/C-04584"],"lab_section":"Wydział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Temperatura\nZakres (1,0 – 50,0) °C PN/77/C-04584 Woda Temperatura\nZakres (1,0 – 50,0) °C PN/77/C-04584","categories":["water"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Temperature","parameters_en":[{"name":"Range","range":"(1,0 – 50,0) °C"}],"search_en":"Water Temperature Range PN/77/C-04584","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(1,0 – 50,0) °C"}],"search_zh":"水 温度 范围 PN/77/C-04584","test_object_zh":"水","methodology_zh":"温度"},{"_id":"6a83703faf14b9c0e7b1ee67","lab_id":"69ad52a3de79e566650fb281","country":"PL","accr_number":"AB 506","accr_body":"PCA","test_object":"Woda","methodology":"Poziom zwierciadła wody","parameters":[{"name":"Zakres","range":"(0,01 – 25,00) m"}],"technique":null,"techniques":[],"computed":[],"activity":"Poziom zwierciadła wody\nZakres (0,01 – 25,00) m","reference":"IS-40 wydanie B z dnia 15.05.2026","norm_bases":["IS-40 wydanie B z dnia 15.05.2026"],"lab_section":"Wydział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Poziom zwierciadła wody\nZakres (0,01 – 25,00) m IS-40 wydanie B z dnia 15.05.2026 Woda Poziom zwierciadla wody\nZakres (0,01 – 25,00) m IS-40 wydanie B z dnia 15.05.2026","categories":["water"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,01 – 25,00) m"}],"search_en":"Water Range IS-40 wydanie B z dnia 15.05.2026","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,01 – 25,00) m"}],"search_zh":"水 范围 IS-40 wydanie B z dnia 15.05.2026","test_object_zh":"水"},{"_id":"6a83703faf14b9c0e7b1ee68","lab_id":"69ad52a3de79e566650fb281","country":"PL","accr_number":"AB 506","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie anionów","parameters":[{"name":"chlorki","range":"(1,0 – 30000) mg/l"},{"name":"siarczany","range":"(1,0 – 2500) mg/l"},{"name":"fluorki","range":"(0,10 – 50,0) mg/l"},{"name":"azotyny","range":"(0,010 – 100) mg/l"},{"name":"azotany","range":"(0,10 – 200) mg/l"},{"name":"fosforany","range":"(0,10 – 100) mg/l"},{"name":"azot azotynowy","range":"(0,0030 – 30) mg/l"},{"name":"azot azotanowy","range":"(0,022 – 45) mg/l"},{"name":"fosfor fosforanowy","range":"(0,033 – 33) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie anionów\nZakres:\nchlorki (1,0 – 30000) mg/l\nsiarczany (1,0 – 2500) mg/l\nfluorki (0,10 – 50,0) mg/l\nazotyny (0,010 – 100) mg/l\nazotany (0,10 – 200) mg/l\nfosforany (0,10 – 100) mg/l\nazot azotynowy (0,0030 – 30) mg/l\nazot azotanowy (0,022 – 45) mg/l\nfosfor fosforanowy (0,033 – 33) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":"Wydział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie anionów\nZakres:\nchlorki (1,0 – 30000) mg/l\nsiarczany (1,0 – 2500) mg/l\nfluorki (0,10 – 50,0) mg/l\nazotyny (0,010 – 100) mg/l\nazotany (0,10 – 200) mg/l\nfosforany (0,10 – 100) mg/l\nazot azotynowy (0,0030 – 30) mg/l\nazot azotanowy (0,022 – 45) mg/l\nfosfor fosforanowy (0,033 – 33) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Woda, Scieki Stezenie anionow\nZakres:\nchlorki (1,0 – 30000) mg/l\nsiarczany (1,0 – 2500) mg/l\nfluorki (0,10 – 50,0) mg/l\nazotyny (0,010 – 100) mg/l\nazotany (0,10 – 200) mg/l\nfosforany (0,10 – 100) mg/l\nazot azotynowy (0,0030 – 30) mg/l\nazot azotanowy (0,022 – 45) mg/l\nfosfor fosforanowy (0,033 – 33) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Anion concentrations","parameters_en":[{"name":"chlorides","range":"(1,0 – 30000) mg/l"},{"name":"sulfates","range":"(1,0 – 2500) mg/l"},{"name":"fluorides","range":"(0,10 – 50,0) mg/l"},{"name":"nitrites","range":"(0,010 – 100) mg/l"},{"name":"nitrates","range":"(0,10 – 200) mg/l"},{"name":"phosphates","range":"(0,10 – 100) mg/l"},{"name":"nitrite nitrogen","range":"(0,0030 – 30) mg/l"},{"name":"nitrate nitrogen","range":"(0,022 – 45) mg/l"},{"name":"phosphate phosphorus","range":"(0,033 – 33) mg/l"}],"search_en":"Water, Wastewater Anion concentrations Ion chromatography with conductometric detection (IC-CD) chlorides sulfates fluorides nitrites nitrates phosphates nitrite nitrogen nitrate nitrogen phosphate phosphorus PN-EN ISO 10304-1:2009+AC:2012","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water, Wastewater","methodology_zh":"阴离子浓度","search_zh":"水、污水 阴离子浓度 离子色谱-电导检测法（IC-CD） 氯化物 硫酸盐 氟化物 亚硝酸盐 硝酸盐 磷酸盐 亚硝酸盐氮 硝酸盐氮 PN-EN ISO 10304-1:2009+AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水、污水","parameters_zh":[{"name":"氯化物","range":"(1,0 – 30000) mg/l"},{"name":"硫酸盐","range":"(1,0 – 2500) mg/l"},{"name":"氟化物","range":"(0,10 – 50,0) mg/l"},{"name":"亚硝酸盐","range":"(0,010 – 100) mg/l"},{"name":"硝酸盐","range":"(0,10 – 200) mg/l"},{"name":"磷酸盐","range":"(0,10 – 100) mg/l"},{"name":"亚硝酸盐氮","range":"(0,0030 – 30) mg/l"},{"name":"硝酸盐氮","range":"(0,022 – 45) mg/l"},{"name":"fosfor fosforanowy","range":"(0,033 – 33) mg/l"}]},{"_id":"6a83703faf14b9c0e7b1ee69","lab_id":"69ad52a3de79e566650fb281","country":"PL","accr_number":"AB 506","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Wydział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki pH\nZakres 2,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, Scieki pH\nZakres 2,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 – 10,0"}],"search_en":"Water, Wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water, Wastewater","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 10,0"}],"search_zh":"水、污水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、污水"},{"_id":"6a83703faf14b9c0e7b1ee6a","lab_id":"69ad52a3de79e566650fb281","country":"PL","accr_number":"AB 506","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie pierwiastków","parameters":[{"name":"bor","range":"(0,10 – 250) mg/l"},{"name":"chrom","range":"(0,0010 – 1,5) mg/l"},{"name":"nikiel","range":"(0,0010 – 1,5) mg/l"},{"name":"miedź","range":"(0,0030 – 1,5) mg/l"},{"name":"cynk","range":"(0,010 – 7,5) mg/l"},{"name":"kadm","range":"(0,0010 – 0,50) mg/l"},{"name":"arsen","range":"(0,010 – 1,5) mg/l"},{"name":"ołów","range":"(0,0030 – 1,5) mg/l"},{"name":"kobalt","range":"(0,0010 – 1,5) mg/l"},{"name":"żelazo","range":"(0,010 – 50) mg/l"},{"name":"glin","range":"(0,010 – 5,0) mg/l"},{"name":"mangan","range":"(0,010 – 1,5) mg/l"},{"name":"fosfor","range":"(0,10 – 50) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie pierwiastków\nZakres:\nbor (0,10 – 250) mg/l\nchrom (0,0010 – 1,5) mg/l\nnikiel (0,0010 – 1,5) mg/l\nmiedź (0,0030 – 1,5) mg/l\ncynk (0,010 – 7,5) mg/l\nkadm (0,0010 – 0,50) mg/l\narsen (0,010 – 1,5) mg/l\nołów (0,0030 – 1,5) mg/l\nkobalt (0,0010 – 1,5) mg/l\nżelazo (0,010 – 50) mg/l\nglin (0,010 – 5,0) mg/l\nmangan (0,010 – 1,5) mg/l\nfosfor (0,10 – 50) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":"Wydział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie pierwiastków\nZakres:\nbor (0,10 – 250) mg/l\nchrom (0,0010 – 1,5) mg/l\nnikiel (0,0010 – 1,5) mg/l\nmiedź (0,0030 – 1,5) mg/l\ncynk (0,010 – 7,5) mg/l\nkadm (0,0010 – 0,50) mg/l\narsen (0,010 – 1,5) mg/l\nołów (0,0030 – 1,5) mg/l\nkobalt (0,0010 – 1,5) mg/l\nżelazo (0,010 – 50) mg/l\nglin (0,010 – 5,0) mg/l\nmangan (0,010 – 1,5) mg/l\nfosfor (0,10 – 50) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Woda, Scieki Stezenie pierwiastkow\nZakres:\nbor (0,10 – 250) mg/l\nchrom (0,0010 – 1,5) mg/l\nnikiel (0,0010 – 1,5) mg/l\nmiedz (0,0030 – 1,5) mg/l\ncynk (0,010 – 7,5) mg/l\nkadm (0,0010 – 0,50) mg/l\narsen (0,010 – 1,5) mg/l\nolow (0,0030 – 1,5) mg/l\nkobalt (0,0010 – 1,5) mg/l\nzelazo (0,010 – 50) mg/l\nglin (0,010 – 5,0) mg/l\nmangan (0,010 – 1,5) mg/l\nfosfor (0,10 – 50) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["water","materials"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element concentration","parameters_en":[{"name":"boron","range":"(0,10 – 250) mg/l"},{"name":"chromium","range":"(0,0010 – 1,5) mg/l"},{"name":"nickel","range":"(0,0010 – 1,5) mg/l"},{"name":"copper","range":"(0,0030 – 1,5) mg/l"},{"name":"zinc","range":"(0,010 – 7,5) mg/l"},{"name":"cadmium","range":"(0,0010 – 0,50) mg/l"},{"name":"arsenic","range":"(0,010 – 1,5) mg/l"},{"name":"lead","range":"(0,0030 – 1,5) mg/l"},{"name":"cobalt","range":"(0,0010 – 1,5) mg/l"},{"name":"iron","range":"(0,010 – 50) mg/l"},{"name":"aluminium","range":"(0,010 – 5,0) mg/l"},{"name":"manganese","range":"(0,010 – 1,5) mg/l"},{"name":"phosphorus","range":"(0,10 – 50) mg/l"}],"search_en":"Water, Wastewater Element concentration Inductively coupled plasma optical emission spectrometry (ICP-OES) boron chromium nickel copper zinc cadmium arsenic lead cobalt iron aluminium manganese phosphorus PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Water, Wastewater","methodology_zh":"元素浓度","parameters_zh":[{"name":"硼","range":"(0,10 – 250) mg/l"},{"name":"铬","range":"(0,0010 – 1,5) mg/l"},{"name":"镍","range":"(0,0010 – 1,5) mg/l"},{"name":"铜","range":"(0,0030 – 1,5) mg/l"},{"name":"锌","range":"(0,010 – 7,5) mg/l"},{"name":"镉","range":"(0,0010 – 0,50) mg/l"},{"name":"砷","range":"(0,010 – 1,5) mg/l"},{"name":"铅","range":"(0,0030 – 1,5) mg/l"},{"name":"钴","range":"(0,0010 – 1,5) mg/l"},{"name":"铁","range":"(0,010 – 50) mg/l"},{"name":"铝","range":"(0,010 – 5,0) mg/l"},{"name":"锰","range":"(0,010 – 1,5) mg/l"},{"name":"磷","range":"(0,10 – 50) mg/l"}],"search_zh":"水、污水 元素浓度 电感耦合等离子体原子发射光谱法（ICP-OES） 硼 铬 镍 铜 锌 镉 砷 铅 钴 铁 铝 锰 磷 PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"水、污水"},{"_id":"6a83703faf14b9c0e7b1ee6b","lab_id":"69ad52a3de79e566650fb281","country":"PL","accr_number":"AB 506","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie rtęci","parameters":[{"name":"Zakres","range":"(0,00010 – 0,02) mg/l"},{"name":"Zakres","range":"(0,10 – 20) µg/l"}],"technique":"Metoda fluorescencyjnej spektrometrii atomowej z generowaniem zimnych par (CVAFS)","techniques":["Metoda fluorescencyjnej spektrometrii atomowej z generowaniem zimnych par (CVAFS)"],"computed":[],"activity":"Stężenie rtęci\nZakres:\nZakres (0,00010 – 0,02) mg/l\nZakres (0,10 – 20) µg/l\nMetoda fluorescencyjnej spektrometrii atomowej z generowaniem zimnych par (CVAFS)","reference":"PN-EN ISO 17852:2009","norm_bases":["PN-EN ISO 17852:2009"],"lab_section":"Wydział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie rtęci\nZakres:\nZakres (0,00010 – 0,02) mg/l\nZakres (0,10 – 20) µg/l\nMetoda fluorescencyjnej spektrometrii atomowej z generowaniem zimnych par (CVAFS) PN-EN ISO 17852:2009 Woda, Scieki Stezenie rteci\nZakres:\nZakres (0,00010 – 0,02) mg/l\nZakres (0,10 – 20) µg/l\nMetoda fluorescencyjnej spektrometrii atomowej z generowaniem zimnych par (CVAFS) PN-EN ISO 17852:2009","categories":["water"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury concentration","parameters_en":[{"name":"Range","range":"(0,00010 – 0,02) mg/l"},{"name":"Range","range":"(0,10 – 20) µg/l"}],"search_en":"Water, Wastewater Mercury concentration Cold vapour atomic fluorescence spectrometry (CVAFS) Range Range PN-EN ISO 17852:2009","technique_en":"Cold vapour atomic fluorescence spectrometry (CVAFS)","test_object_en":"Water, Wastewater","methodology_zh":"汞浓度","parameters_zh":[{"name":"范围","range":"(0,00010 – 0,02) mg/l"},{"name":"范围","range":"(0,10 – 20) µg/l"}],"search_zh":"水、污水 汞浓度 冷蒸气原子荧光光谱法（CVAFS） 范围 范围 PN-EN ISO 17852:2009","test_object_zh":"水、污水","technique_zh":"冷蒸气原子荧光光谱法（CVAFS）"},{"_id":"6a83703faf14b9c0e7b1ee6c","lab_id":"69ad52a3de79e566650fb281","country":"PL","accr_number":"AB 506","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"100,0 μS/cm – 50,0 mS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres 100,0 μS/cm – 50,0 mS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Wydział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Przewodność elektryczna właściwa\nZakres 100,0 μS/cm – 50,0 mS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, Scieki Przewodnosc elektryczna wlasciwa\nZakres 100,0 μS/cm – 50,0 mS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"100,0 μS/cm – 50,0 mS/cm"}],"search_en":"Water, Wastewater Electrical conductivity Conductometric method Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water, Wastewater","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"100,0 μS/cm – 50,0 mS/cm"}],"search_zh":"水、污水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、污水"},{"_id":"6a83703faf14b9c0e7b1ee6d","lab_id":"69ad52a3de79e566650fb281","country":"PL","accr_number":"AB 506","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie kationów","parameters":[{"name":"Sód","range":"(1,0 – 1000) mg/l"},{"name":"Jon amonowy","range":"(0,10 – 1000) mg/l"},{"name":"Potas","range":"(1,0 – 100) mg/l"},{"name":"Magnez","range":"(1,0 – 1000) mg/l"},{"name":"Wapń","range":"(1,0 – 1000) mg/l"},{"name":"Azot amonowy","range":"(0,078 – 780) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie kationów\nZakres:\nSód (1,0 – 1000) mg/l\nJon amonowy (0,10 – 1000) mg/l\nPotas (1,0 – 100) mg/l\nMagnez (1,0 – 1000) mg/l\nWapń (1,0 – 1000) mg/l\nAzot amonowy (0,078 – 780) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 14911:2002","norm_bases":["PN-EN ISO 14911:2002"],"lab_section":"Wydział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie kationów\nZakres:\nSód (1,0 – 1000) mg/l\nJon amonowy (0,10 – 1000) mg/l\nPotas (1,0 – 100) mg/l\nMagnez (1,0 – 1000) mg/l\nWapń (1,0 – 1000) mg/l\nAzot amonowy (0,078 – 780) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 14911:2002 Woda, Scieki Stezenie kationow\nZakres:\nSod (1,0 – 1000) mg/l\nJon amonowy (0,10 – 1000) mg/l\nPotas (1,0 – 100) mg/l\nMagnez (1,0 – 1000) mg/l\nWapn (1,0 – 1000) mg/l\nAzot amonowy (0,078 – 780) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 14911:2002","categories":["water"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Cation concentrations","parameters_en":[{"name":"Sodium","range":"(1,0 – 1000) mg/l"},{"name":"Ammonium ion","range":"(0,10 – 1000) mg/l"},{"name":"Potassium","range":"(1,0 – 100) mg/l"},{"name":"Magnesium","range":"(1,0 – 1000) mg/l"},{"name":"Calcium","range":"(1,0 – 1000) mg/l"},{"name":"Ammonium nitrogen","range":"(0,078 – 780) mg/l"}],"search_en":"Water, Wastewater Cation concentrations Ion chromatography with conductometric detection (IC-CD) Sodium Ammonium ion Potassium Magnesium Calcium Ammonium nitrogen PN-EN ISO 14911:2002","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water, Wastewater","search_zh":"水、污水 阳离子浓度 离子色谱-电导检测法（IC-CD） 钠 钾 镁 钙 PN-EN ISO 14911:2002","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水、污水","parameters_zh":[{"name":"钠","range":"(1,0 – 1000) mg/l"},{"name":"Jon amonowy","range":"(0,10 – 1000) mg/l"},{"name":"钾","range":"(1,0 – 100) mg/l"},{"name":"镁","range":"(1,0 – 1000) mg/l"},{"name":"钙","range":"(1,0 – 1000) mg/l"},{"name":"Azot amonowy","range":"(0,078 – 780) mg/l"}],"methodology_zh":"阳离子浓度"},{"_id":"6a83703faf14b9c0e7b1ee6e","lab_id":"69ad52a3de79e566650fb281","country":"PL","accr_number":"AB 506","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Sumaryczne stężenie wapnia i magnezu (twardość ogólna)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Sumaryczne stężenie wapnia i magnezu (twardość ogólna)","reference":"IS-37 wydanie B z dnia 31.03.2026","norm_bases":["IS-37 wydanie B z dnia 31.03.2026"],"lab_section":"Wydział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Sumaryczne stężenie wapnia i magnezu (twardość ogólna) IS-37 wydanie B z dnia 31.03.2026 Woda, Scieki Sumaryczne stezenie wapnia i magnezu (twardosc ogolna) IS-37 wydanie B z dnia 31.03.2026","categories":["water"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total concentration of calcium and magnesium (total hardness)","search_en":"Water, Wastewater Total concentration of calcium and magnesium (total hardness) IS-37 wydanie B z dnia 31.03.2026","test_object_en":"Water, Wastewater","search_zh":"水、污水 钙与镁的总浓度（总硬度） IS-37 wydanie B z dnia 31.03.2026","test_object_zh":"水、污水","methodology_zh":"钙与镁的总浓度（总硬度）"},{"_id":"6a83703faf14b9c0e7b1ee6f","lab_id":"69ad52a3de79e566650fb281","country":"PL","accr_number":"AB 506","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Twardość wapniowa (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Twardość wapniowa (z obliczeń)","reference":"IS-37 wydanie B z dnia 31.03.2026","norm_bases":["IS-37 wydanie B z dnia 31.03.2026"],"lab_section":"Wydział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Twardość wapniowa (z obliczeń) IS-37 wydanie B z dnia 31.03.2026 Woda, Scieki Twardosc wapniowa (z obliczen) IS-37 wydanie B z dnia 31.03.2026","categories":["water"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Calcium hardness (calculated)","search_en":"Water, Wastewater Calcium hardness (calculated) IS-37 wydanie B z dnia 31.03.2026","test_object_en":"Water, Wastewater","search_zh":"水、污水 IS-37 wydanie B z dnia 31.03.2026","test_object_zh":"水、污水"},{"_id":"6a83703faf14b9c0e7b1ee70","lab_id":"69ad52a3de79e566650fb281","country":"PL","accr_number":"AB 506","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr","parameters":[{"name":"Zakres","range":"(10,0 – 3000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (10,0 – 3000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Wydział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (10,0 – 3000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda, Scieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (10,0 – 3000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand - COD-Cr","parameters_en":[{"name":"Range","range":"(10,0 – 3000) mg/l O2"}],"search_en":"Water, Wastewater Chemical oxygen demand - COD-Cr Spectrophotometric method Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(10,0 – 3000) mg/l O2"}],"search_zh":"水、污水 化学需氧量（COD-Cr） 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水、污水","methodology_zh":"化学需氧量（COD-Cr）"}],"has_pdf":true}