{"lab":{"_id":"69ad52a3de79e566650fb271","accr_number":"AB 492","country":"PL","accr_body":"PCA","address":"WE WROCŁAWIU, ul. Marii Curie-Skłodowskiej 73/77, 50-950 Wrocław","categories":["water","food","microbiology","environment","materials","pharma"],"city":"Wrocław","imported_at":"2026-03-08T10:42:43.265Z","methods_count":119,"name":"WOJEWÓDZKA STACJA SANITARNO-EPIDEMIOLOGICZNA","parse_status":"parsed","parse_version":3,"pdf_files":["AB_492.pdf"],"scope_summary":"","search_text":"wojewódzka stacja sanitarno-epidemiologiczna we wrocławiu, ul. marii curie-skłodowskiej 73/77, 50-950 wrocław food other water pharma electronics materials petro metrology automotive microbiology environment","status":"active","updated_at":"2026-03-08T14:51:20.753Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-17T20:32:56.789Z","location":{"type":"Point","coordinates":[17.0385,51.1079]},"email_confidence":"high","email_mx":true,"email_source":"https://www.gov.pl/web/wsse-wroclaw/kontakt-wsse","fields_of_testing":[{"codes":"C/1; C/12; C/21; C/22; C/28; C/29; C/49","pl":"Badania chemiczne produktów rolnych; szkła i ceramiki; wyrobów z tworzyw sztucznych; żywności; wody; wody do spożycia przez ludzi; materiałów opakowaniowych","en":"Chemical tests of agricultural products; glass and ceramics; plastic products; food; water; drinking water, packaging materials;"},{"codes":"D/3","pl":"Badania kliniczne, medyczne obiektów i materiałów biologicznych przeznaczonych do badań","en":"Clinical, medical tests of biological items and materials for testing"},{"codes":"K/3; K/9; K/22; K/28; K/29; K/31; K/35, K/42, K/17","pl":"Badania mikrobiologiczne obiektów i materiałów biologicznych przeznaczonych do badań; powietrza, żywności; wody; wody do spożycia przez ludzi; gleby, gruntów, skał; pomieszczeń (warunki środowiskowe); kosmetyków; innych wyrobów","en":"Microbiological tests of biological items and materials for testing; air; food; water; drinking water; soil, rocks, facilities (environmental conditions); cosmetics; other products"},{"codes":"N/22; N/28; N/29","pl":"Badania właściwości fizycznych żywności; wody; wody do spożycia przez ludzi","en":"Tests of physical properties of food; water; drinking water;"},{"codes":"Q/1; Q/21; Q/22; Q/29; Q/49","pl":"Badania sensoryczne produktów rolnych; wyrobów z tworzyw sztucznych; żywności; wody do spożycia przez ludzi; materiałów opakowaniowych","en":"Sensory tests of agricultural products; plastic products; food; drinking water; food packaging materials"}],"issue":{"no":"27","date":"29.05.2026"},"parse_date":"2026-08-17T20:32:56.789Z","parse_source":"agent-claude-code","map_coord":[51.108978,17.066317],"map_geo":"nominatim-street","lab_locations":[{"name":"Dział Laboratoryjny/ Oddział Badania Żywności","address":"ul. Marii Curie-Skłodowskiej 73/77, 50-950 Wrocław","city":"Wrocław","postal":"50-950"},{"name":"Pracownia Badań Chemicznych Żywności","address":"ul. Marii Curie-Skłodowskiej 73/77, 50-950 Wrocław","city":"Wrocław","postal":"50-950"},{"name":"Pracownia Analiz Instrumentalnych","address":"ul. Marii Curie-Skłodowskiej 73/77, 50-950 Wrocław","city":"Wrocław","postal":"50-950"},{"name":"Dział Laboratoryjny/ Oddział Badania Wody i Gleby","address":"ul. Marii Curie-Skłodowskiej 73/77, 50-950 Wrocław","city":"Wrocław","postal":"50-950"},{"name":"Pracownia Badań Chemicznych Wody","address":"ul. Marii Curie-Skłodowskiej 73/77, 50-950 Wrocław","city":"Wrocław","postal":"50-950"},{"name":"Pracownia Badań Materiałów i Wyrobów do Kontaktu z Żywnością","address":"ul. Marii Curie-Skłodowskiej 73/77, 50-950 Wrocław","city":"Wrocław","postal":"50-950"},{"name":"Pracownia Badań Mikrobiologicznych Wody i Gleby","address":"ul. Marii Curie-Skłodowskiej 73/77, 50-950 Wrocław","city":"Wrocław","postal":"50-950"},{"name":"Pracownia Badań Mikrobiologicznych Żywności","address":"ul. Marii Curie-Skłodowskiej 73/77, 50-950 Wrocław","city":"Wrocław","postal":"50-950"},{"name":"Dział Laboratoryjny/ Oddział Mikrobiologii i Parazytologii","address":"ul. Składowa 1/3, 50-950 Wrocław","city":"Wrocław","postal":"50-950"},{"name":"Pracownia Schorzeń Jelitowych","address":"ul. Składowa 1/3, 50-950 Wrocław","city":"Wrocław","postal":"50-950"},{"name":"Pracownia Bakteriologii Ogólnej i Parazytologii","address":"ul. Składowa 1/3, 50-950 Wrocław","city":"Wrocław","postal":"50-950"},{"name":"Pracownia Badań Czystościowych i Szkodliwych Czynników Biologicznych","address":"ul. Składowa 1/3, 50-950 Wrocław","city":"Wrocław","postal":"50-950"},{"name":"Pracownia Wirusologii i Serologii","address":"ul. Składowa 1/3, 50-950 Wrocław","city":"Wrocław","postal":"50-950"},{"name":"Dział Laboratoryjny/ Oddział Badania Żywności; Pracownia Badań Materiałów i Wyrobów do Kontaktu z Żywnością","address":null,"city":null,"postal":null},{"name":"Dział Laboratoryjny/ Oddział Badania Wody i Gleby; Pracownia Badań Chemicznych Wody","address":null,"city":null,"postal":null},{"name":"Dział Laboratoryjny/ Oddział Badania Wody i Gleby; Pracownia Badań Chemicznych Wody; Pracownia Analiz Instrumentalnych","address":null,"city":null,"postal":null},{"name":"Dział Laboratoryjny/ Oddział Badania Wody i Gleby; Pracownia Badań Mikrobiologicznych Wody i Gleby","address":null,"city":null,"postal":null},{"name":"Dział Laboratoryjny/ Oddział Badania Żywności; Pracownia Badań Chemicznych Żywności","address":null,"city":null,"postal":null},{"name":"Dział Laboratoryjny/ Oddział Badania Żywności; Pracownia Badań Chemicznych Żywności; Pracownia Analiz Instrumentalnych","address":null,"city":null,"postal":null},{"name":"Dział Laboratoryjny/ Oddział Badania Żywności; Pracownia Badań Materiałów i Wyrobów do Kontaktu z Żywnością; Pracownia Analiz Instrumentalnych","address":null,"city":null,"postal":null},{"name":"Dział Laboratoryjny/ Oddział Badania Żywności; Pracownia Badań Mikrobiologicznych Żywności","address":null,"city":null,"postal":null},{"name":"Dział Laboratoryjny/ Oddział Mikrobiologii i Parazytologii; Pracownia Badań Czystościowych i Szkodliwych Czynników Biologicznych","address":null,"city":null,"postal":null},{"name":"Dział Laboratoryjny/ Oddział Mikrobiologii i Parazytologii; Pracownia Bakteriologii Ogólnej i Parazytologii","address":null,"city":null,"postal":null},{"name":"Dział Laboratoryjny/ Oddział Mikrobiologii i Parazytologii; Pracownia Schorzeń Jelitowych","address":null,"city":null,"postal":null},{"name":"Dział Laboratoryjny/ Oddział Mikrobiologii i Parazytologii; Pracownia Wirusologii i Serologii","address":null,"city":null,"postal":null}],"scope_format":"PCA::pracownie+elastyczny+siatka5","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/8c09468f666cfa27180693f363d64365/AB%20492.pdf","has_en":true,"category_counts":{"water":49,"food":34,"microbiology":31,"other":15,"environment":12,"materials":9,"pharma":7},"category_scores":{"water":15.29,"food":7.36,"microbiology":6.12,"other":1.43,"environment":0.92,"materials":0.52,"pharma":0.31},"has_zh":true,"lab_locations_zh":[{"name":"Dział Laboratoryjny/ Oddział Badania Żywności","address":"ul. Marii Curie-Skłodowskiej 73/77, 50-950 Wrocław","city":"Wrocław","postal":"50-950"},{"name":"Pracownia Badań Chemicznych Żywności","address":"ul. Marii Curie-Skłodowskiej 73/77, 50-950 Wrocław","city":"Wrocław","postal":"50-950"},{"name":"仪器分析检验室","address":"ul. Marii Curie-Skłodowskiej 73/77, 50-950 Wrocław","city":"Wrocław","postal":"50-950"},{"name":"Dział Laboratoryjny/ Oddział Badania Wody i Gleby","address":"ul. Marii Curie-Skłodowskiej 73/77, 50-950 Wrocław","city":"Wrocław","postal":"50-950"},{"name":"Pracownia Badań Chemicznych Wody","address":"ul. Marii Curie-Skłodowskiej 73/77, 50-950 Wrocław","city":"Wrocław","postal":"50-950"},{"name":"Pracownia Badań Materiałów i Wyrobów do Kontaktu z Żywnością","address":"ul. Marii Curie-Skłodowskiej 73/77, 50-950 Wrocław","city":"Wrocław","postal":"50-950"},{"name":"Pracownia Badań Mikrobiologicznych Wody i Gleby","address":"ul. Marii Curie-Skłodowskiej 73/77, 50-950 Wrocław","city":"Wrocław","postal":"50-950"},{"name":"Pracownia Badań Mikrobiologicznych Żywności","address":"ul. Marii Curie-Skłodowskiej 73/77, 50-950 Wrocław","city":"Wrocław","postal":"50-950"},{"name":"Dział Laboratoryjny/ Oddział Mikrobiologii i Parazytologii","address":"ul. Składowa 1/3, 50-950 Wrocław","city":"Wrocław","postal":"50-950"},{"name":"Pracownia Schorzeń Jelitowych","address":"ul. Składowa 1/3, 50-950 Wrocław","city":"Wrocław","postal":"50-950"},{"name":"Pracownia Bakteriologii Ogólnej i Parazytologii","address":"ul. Składowa 1/3, 50-950 Wrocław","city":"Wrocław","postal":"50-950"},{"name":"Pracownia Badań Czystościowych i Szkodliwych Czynników Biologicznych","address":"ul. Składowa 1/3, 50-950 Wrocław","city":"Wrocław","postal":"50-950"},{"name":"Pracownia Wirusologii i Serologii","address":"ul. Składowa 1/3, 50-950 Wrocław","city":"Wrocław","postal":"50-950"},{"name":"Dział Laboratoryjny/ Oddział Badania Żywności; Pracownia Badań Materiałów i Wyrobów do Kontaktu z Żywnością","address":null,"city":null,"postal":null},{"name":"Dział Laboratoryjny/ Oddział Badania Wody i Gleby; Pracownia Badań Chemicznych Wody","address":null,"city":null,"postal":null},{"name":"Dział Laboratoryjny/ Oddział Badania Wody i Gleby; Pracownia Badań Chemicznych Wody; Pracownia Analiz Instrumentalnych","address":null,"city":null,"postal":null},{"name":"Dział Laboratoryjny/ Oddział Badania Wody i Gleby; Pracownia Badań Mikrobiologicznych Wody i Gleby","address":null,"city":null,"postal":null},{"name":"Dział Laboratoryjny/ Oddział Badania Żywności; Pracownia Badań Chemicznych Żywności","address":null,"city":null,"postal":null},{"name":"Dział Laboratoryjny/ Oddział Badania Żywności; Pracownia Badań Chemicznych Żywności; Pracownia Analiz Instrumentalnych","address":null,"city":null,"postal":null},{"name":"Dział Laboratoryjny/ Oddział Badania Żywności; Pracownia Badań Materiałów i Wyrobów do Kontaktu z Żywnością; Pracownia Analiz Instrumentalnych","address":null,"city":null,"postal":null},{"name":"Dział Laboratoryjny/ Oddział Badania Żywności; Pracownia Badań Mikrobiologicznych Żywności","address":null,"city":null,"postal":null},{"name":"Dział Laboratoryjny/ Oddział Mikrobiologii i Parazytologii; Pracownia Badań Czystościowych i Szkodliwych Czynników Biologicznych","address":null,"city":null,"postal":null},{"name":"Dział Laboratoryjny/ Oddział Mikrobiologii i Parazytologii; Pracownia Bakteriologii Ogólnej i Parazytologii","address":null,"city":null,"postal":null},{"name":"Dział Laboratoryjny/ Oddział Mikrobiologii i Parazytologii; Pracownia Schorzeń Jelitowych","address":null,"city":null,"postal":null},{"name":"Dział Laboratoryjny/ Oddział Mikrobiologii i Parazytologii; Pracownia Wirusologii i Serologii","address":null,"city":null,"postal":null}]},"methods":[{"_id":"6a836ff8af14b9c0e7b1edc7","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Żywność pochodzenia roślinnego, produkty rolne - o wysokiej zawartości wody - o wysokiej zawartości kwasów i wysokiej zawartości wody - o wysokiej zawartości skrobi i/lub białka oraz niskiej zawartości wody i tłuszczu","methodology":"Zawartość pozostałości pestycydów","parameters":[{"name":"ditiokarbaminiany wyrażone jako CS2"},{"name":"Zakres","range":"(0,15 – 10,0) mg/kg"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość pozostałości pestycydów\nZakres:\nditiokarbaminiany wyrażone jako CS2\nZakres (0,15 – 10,0) mg/kg\nMetoda spektrofotometryczna","reference":"PN-EN 12396-1:2002","norm_bases":["PN-EN 12396-1:2002"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Żywności; Pracownia Badań Chemicznych Żywności","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Żywność pochodzenia roślinnego, produkty rolne - o wysokiej zawartości wody - o wysokiej zawartości kwasów i wysokiej zawartości wody - o wysokiej zawartości skrobi i/lub białka oraz niskiej zawartości wody i tłuszczu Zawartość pozostałości pestycydów\nZakres:\nditiokarbaminiany wyrażone jako CS2\nZakres (0,15 – 10,0) mg/kg\nMetoda spektrofotometryczna PN-EN 12396-1:2002 Zywnosc pochodzenia roslinnego, produkty rolne - o wysokiej zawartosci wody - o wysokiej zawartosci kwasow i wysokiej zawartosci wody - o wysokiej zawartosci skrobi i/lub bialka oraz niskiej zawartosci wody i tluszczu Zawartosc pozostalosci pestycydow\nZakres:\nditiokarbaminiany wyrazone jako CS2\nZakres (0,15 – 10,0) mg/kg\nMetoda spektrofotometryczna PN-EN 12396-1:2002","categories":["water","food"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Pesticide residue content","parameters_en":[{"name":"dithiocarbamates expressed as CS2"},{"name":"Range","range":"(0,15 – 10,0) mg/kg"}],"search_en":"Food of plant origin, agricultural products - with high water content - with high acid content and high water content - with high starch and/or protein content and low water and fat content Pesticide residue content Spectrophotometric method dithiocarbamates expressed as CS2 Range PN-EN 12396-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Food of plant origin, agricultural products - with high water content - with high acid content and high water content - with high starch and/or protein content and low water and fat content","methodology_zh":"农药残留含量","parameters_zh":[{"name":"ditiokarbaminiany wyrażone jako CS2"},{"name":"范围","range":"(0,15 – 10,0) mg/kg"}],"search_zh":"农药残留含量 分光光度法 范围 PN-EN 12396-1:2002","technique_zh":"分光光度法"},{"_id":"6a836ff8af14b9c0e7b1edc8","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Żywność pochodzenia roślinnego, produkty rolne - o wysokiej zawartości wody - o wysokiej zawartości kwasów i wysokiej zawartości wody - o wysokiej zawartości skrobi i/lub białka oraz niskiej zawartości wody i tłuszczu","methodology":"Zawartość pozostałości pestycydów","parameters":[{"name":"ditiokarbaminiany wyrażone jako CS2"},{"name":"Zakres","range":"(0,01 – 0,80) mg/kg"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość pozostałości pestycydów\nZakres:\nditiokarbaminiany wyrażone jako CS2\nZakres (0,01 – 0,80) mg/kg\nMetoda spektrofotometryczna","reference":"PN-EN 12396-3:2002","norm_bases":["PN-EN 12396-3:2002"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Żywności; Pracownia Badań Chemicznych Żywności","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Żywność pochodzenia roślinnego, produkty rolne - o wysokiej zawartości wody - o wysokiej zawartości kwasów i wysokiej zawartości wody - o wysokiej zawartości skrobi i/lub białka oraz niskiej zawartości wody i tłuszczu Zawartość pozostałości pestycydów\nZakres:\nditiokarbaminiany wyrażone jako CS2\nZakres (0,01 – 0,80) mg/kg\nMetoda spektrofotometryczna PN-EN 12396-3:2002 Zywnosc pochodzenia roslinnego, produkty rolne - o wysokiej zawartosci wody - o wysokiej zawartosci kwasow i wysokiej zawartosci wody - o wysokiej zawartosci skrobi i/lub bialka oraz niskiej zawartosci wody i tluszczu Zawartosc pozostalosci pestycydow\nZakres:\nditiokarbaminiany wyrazone jako CS2\nZakres (0,01 – 0,80) mg/kg\nMetoda spektrofotometryczna PN-EN 12396-3:2002","categories":["water","food"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Pesticide residue content","parameters_en":[{"name":"dithiocarbamates expressed as CS2"},{"name":"Range","range":"(0,01 – 0,80) mg/kg"}],"search_en":"Food of plant origin, agricultural products - with high water content - with high acid content and high water content - with high starch and/or protein content and low water and fat content Pesticide residue content Spectrophotometric method dithiocarbamates expressed as CS2 Range PN-EN 12396-3:2002","technique_en":"Spectrophotometric method","test_object_en":"Food of plant origin, agricultural products - with high water content - with high acid content and high water content - with high starch and/or protein content and low water and fat content","methodology_zh":"农药残留含量","parameters_zh":[{"name":"ditiokarbaminiany wyrażone jako CS2"},{"name":"范围","range":"(0,01 – 0,80) mg/kg"}],"search_zh":"农药残留含量 分光光度法 范围 PN-EN 12396-3:2002","technique_zh":"分光光度法"},{"_id":"6a836ff8af14b9c0e7b1edc9","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Mięso i przetwory mięsne, Drób i przetwory drobiowe, Ryby, produkty rybołówstwa i ich przetwory, Zboża i przetwory zbożowe, Warzywa i przetwory warzywne, Owoce i przetwory owocowe, Grzyby, Orzechy, Nasiona roślin oleistych, Zioła i przyprawy, Środki spożywcze specjalnego przeznaczenia żywieniowego, Sól spożywcza i jej zamienniki, Słodycze łącznie z czekoladą. Wyroby cukiernicze, ciastkarskie i czekoladowe. Suplementy diety i podobne, Miód i produkty pszczelarskie, Napoje alkoholowe","methodology":"Wygląd, barwa, smak, zapach","parameters":[],"technique":"Prosty test opisowy","techniques":["Prosty test opisowy"],"computed":[],"activity":"Wygląd, barwa, smak, zapach\nProsty test opisowy","reference":"PB ZZ-05 wydanie 8 z dnia 05.01.2024 r.","norm_bases":["PB ZZ-05 wydanie 8 z dnia 05.01.2024 r."],"lab_section":"Dział Laboratoryjny/ Oddział Badania Żywności; Pracownia Badań Chemicznych Żywności","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i przetwory mięsne, Drób i przetwory drobiowe, Ryby, produkty rybołówstwa i ich przetwory, Zboża i przetwory zbożowe, Warzywa i przetwory warzywne, Owoce i przetwory owocowe, Grzyby, Orzechy, Nasiona roślin oleistych, Zioła i przyprawy, Środki spożywcze specjalnego przeznaczenia żywieniowego, Sól spożywcza i jej zamienniki, Słodycze łącznie z czekoladą. Wyroby cukiernicze, ciastkarskie i czekoladowe. Suplementy diety i podobne, Miód i produkty pszczelarskie, Napoje alkoholowe Wygląd, barwa, smak, zapach\nProsty test opisowy PB ZZ-05 wydanie 8 z dnia 05.01.2024 r. Mieso i przetwory miesne, Drob i przetwory drobiowe, Ryby, produkty rybolowstwa i ich przetwory, Zboza i przetwory zbozowe, Warzywa i przetwory warzywne, Owoce i przetwory owocowe, Grzyby, Orzechy, Nasiona roslin oleistych, Ziola i przyprawy, Srodki spozywcze specjalnego przeznaczenia zywieniowego, Sol spozywcza i jej zamienniki, Slodycze lacznie z czekolada. Wyroby cukiernicze, ciastkarskie i czekoladowe. Suplementy diety i podobne, Miod i produkty pszczelarskie, Napoje alkoholowe Wyglad, barwa, smak, zapach\nProsty test opisowy PB ZZ-05 wydanie 8 z dnia 05.01.2024 r.","categories":["food","microbiology","pharma"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Appearance, colour, taste, odour","search_en":"Meat and meat products, Poultry and poultry products, Fish, fishery products and their preparations, Cereals and cereal products, Vegetables and vegetable products, Fruit and fruit products, Mushrooms, Nuts, Oilseeds, Herbs and spices, Foodstuffs for particular nutritional uses, Edible salt and its substitutes, Sweets including chocolate. Confectionery, pastry and chocolate products. Food supplements and similar, Honey and bee products, Alcoholic beverages Appearance, colour, taste, odour Simple descriptive test PB ZZ-05 wydanie 8 z dnia 05.01.2024 r.","technique_en":"Simple descriptive test","test_object_en":"Meat and meat products, Poultry and poultry products, Fish, fishery products and their preparations, Cereals and cereal products, Vegetables and vegetable products, Fruit and fruit products, Mushrooms, Nuts, Oilseeds, Herbs and spices, Foodstuffs for particular nutritional uses, Edible salt and its substitutes, Sweets including chocolate. Confectionery, pastry and chocolate products. Food supplements and similar, Honey and bee products, Alcoholic beverages"},{"_id":"6a836ff8af14b9c0e7b1edca","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Mleko i przetwory mleczne","methodology":"Wygląd, barwa, smak, zapach","parameters":[],"technique":"Prosty test opisowy","techniques":["Prosty test opisowy"],"computed":[],"activity":"Wygląd, barwa, smak, zapach\nProsty test opisowy","reference":"PN-ISO 22935-2:2013-07","norm_bases":["PN-ISO 22935-2:2013-07"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Żywności; Pracownia Badań Chemicznych Żywności","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mleko i przetwory mleczne Wygląd, barwa, smak, zapach\nProsty test opisowy PN-ISO 22935-2:2013-07 Mleko i przetwory mleczne Wyglad, barwa, smak, zapach\nProsty test opisowy PN-ISO 22935-2:2013-07","categories":["food"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Appearance, colour, taste, odour","search_en":"Milk and milk products Appearance, colour, taste, odour Simple descriptive test PN-ISO 22935-2:2013-07","technique_en":"Simple descriptive test","test_object_en":"Milk and milk products","search_zh":"乳与乳制品 PN-ISO 22935-2:2013-07","test_object_zh":"乳与乳制品"},{"_id":"6a836ff8af14b9c0e7b1edcb","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Ryby, produkty rybołówstwa i ich przetwory","methodology":"Zawartość histaminy","parameters":[{"name":"Zakres","range":"(25,0 – 400,0) mg/kg"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)"],"computed":[],"activity":"Zawartość histaminy\nZakres (25,0 – 400,0) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","reference":"PN-EN ISO 19343:2017-08","norm_bases":["PN-EN ISO 19343:2017-08"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Żywności; Pracownia Badań Chemicznych Żywności; Pracownia Analiz Instrumentalnych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ryby, produkty rybołówstwa i ich przetwory Zawartość histaminy\nZakres (25,0 – 400,0) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV) PN-EN ISO 19343:2017-08 Ryby, produkty rybolowstwa i ich przetwory Zawartosc histaminy\nZakres (25,0 – 400,0) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC-UV) PN-EN ISO 19343:2017-08","categories":["other"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Histamine content","parameters_en":[{"name":"Range","range":"(25,0 – 400,0) mg/kg"}],"search_en":"Fish, fishery products and their preparations Histamine content High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) Range PN-EN ISO 19343:2017-08","technique_en":"High-performance liquid chromatography with spectrophotometric detection (HPLC-UV)","test_object_en":"Fish, fishery products and their preparations","parameters_zh":[{"name":"范围","range":"(25,0 – 400,0) mg/kg"}],"search_zh":"组胺含量 高效液相色谱-分光光度检测法（HPLC-UV） 范围 PN-EN ISO 19343:2017-08","technique_zh":"高效液相色谱-分光光度检测法（HPLC-UV）","methodology_zh":"组胺含量"},{"_id":"6a836ff8af14b9c0e7b1edcc","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość pierwiastków","parameters":[],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"computed":[],"activity":"Zawartość pierwiastków\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Żywności; Pracownia Badań Chemicznych Żywności; Pracownia Analiz Instrumentalnych","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniona publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Zawartość pierwiastków\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) Normy Zywnosc E Zawartosc pierwiastkow\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) Normy","categories":["food"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element content","search_en":"Food E Element content Inductively coupled plasma mass spectrometry (ICP-MS) Normy","technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","test_object_en":"Food E","methodology_zh":"元素含量","search_zh":"食品 E 元素含量 电感耦合等离子体质谱法（ICP-MS） Normy","technique_zh":"电感耦合等离子体质谱法（ICP-MS）","test_object_zh":"食品 E"},{"_id":"6a836ff8af14b9c0e7b1edcd","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość arsenu","parameters":[],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem wodorków (HGAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem wodorków (HGAAS)"],"computed":[],"activity":"Zawartość arsenu\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem wodorków (HGAAS)","reference":"Procedury badawcze Wydawnictwa Metodyczne","norm_bases":["Procedury badawcze Wydawnictwa Metodyczne"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Żywności; Pracownia Badań Chemicznych Żywności; Pracownia Analiz Instrumentalnych","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniona publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Zawartość arsenu\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem wodorków (HGAAS) Procedury badawcze Wydawnictwa Metodyczne Zywnosc E Zawartosc arsenu\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem wodorkow (HGAAS) Procedury badawcze Wydawnictwa Metodyczne","categories":["food"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Arsenic content","search_en":"Food E Arsenic content Hydride generation atomic absorption spectrometry (HGAAS) Procedury badawcze Wydawnictwa Metodyczne","technique_en":"Hydride generation atomic absorption spectrometry (HGAAS)","test_object_en":"Food E","search_zh":"食品 E 砷含量 氢化物发生原子吸收光谱法（HGAAS） Procedury badawcze Wydawnictwa Metodyczne","test_object_zh":"食品 E","technique_zh":"氢化物发生原子吸收光谱法（HGAAS）","methodology_zh":"砷含量"},{"_id":"6a836ff8af14b9c0e7b1edce","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Żywność pochodzenia roślinnego, produkty rolne E","methodology":"Zawartość pozostałości pestycydów","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją wychwytu elektronów, detekcją tendemową spektrometrią mas (GC-ECD; GC-MS-MS)","techniques":["Metoda chromatografii gazowej z detekcją wychwytu elektronów, detekcją tendemową spektrometrią mas (GC-ECD; GC-MS-MS)"],"computed":[],"activity":"Zawartość pozostałości pestycydów\nMetoda chromatografii gazowej z detekcją wychwytu elektronów, detekcją tendemową spektrometrią mas (GC-ECD; GC-MS-MS)","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Żywności; Pracownia Badań Chemicznych Żywności; Pracownia Analiz Instrumentalnych","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniona publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność pochodzenia roślinnego, produkty rolne E Zawartość pozostałości pestycydów\nMetoda chromatografii gazowej z detekcją wychwytu elektronów, detekcją tendemową spektrometrią mas (GC-ECD; GC-MS-MS) Normy Procedury badawcze Zywnosc pochodzenia roslinnego, produkty rolne E Zawartosc pozostalosci pestycydow\nMetoda chromatografii gazowej z detekcja wychwytu elektronow, detekcja tendemowa spektrometria mas (GC-ECD; GC-MS-MS) Normy Procedury badawcze","categories":["food"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Pesticide residue content","search_en":"Food of plant origin, agricultural products E Pesticide residue content Gas chromatography with electron capture detection, tandem mass spectrometry detection (GC-ECD; GC-MS-MS) Normy Procedury badawcze","technique_en":"Gas chromatography with electron capture detection, tandem mass spectrometry detection (GC-ECD; GC-MS-MS)","test_object_en":"Food of plant origin, agricultural products E","methodology_zh":"农药残留含量","search_zh":"植物源食品、农产品 E 农药残留含量 Normy Procedury badawcze","test_object_zh":"植物源食品、农产品 E"},{"_id":"6a836ff8af14b9c0e7b1edcf","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Żywność pochodzenia roślinnego, produkty rolne E","methodology":"Zawartość pozostałości pestycydów","parameters":[],"technique":"Metoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)","techniques":["Metoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)"],"computed":[],"activity":"Zawartość pozostałości pestycydów\nMetoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)","reference":"Normy Procedury badawcze","norm_bases":["Normy Procedury badawcze"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Żywności; Pracownia Badań Chemicznych Żywności; Pracownia Analiz Instrumentalnych","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniona publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność pochodzenia roślinnego, produkty rolne E Zawartość pozostałości pestycydów\nMetoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS) Normy Procedury badawcze Zywnosc pochodzenia roslinnego, produkty rolne E Zawartosc pozostalosci pestycydow\nMetoda chromatografii cieczowej z detekcja tandemowa spektrometria mas (LC-MS-MS) Normy Procedury badawcze","categories":["food"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Pesticide residue content","search_en":"Food of plant origin, agricultural products E Pesticide residue content Liquid chromatography with tandem mass spectrometry detection (LC-MS-MS) Normy Procedury badawcze","technique_en":"Liquid chromatography with tandem mass spectrometry detection (LC-MS-MS)","test_object_en":"Food of plant origin, agricultural products E","methodology_zh":"农药残留含量","search_zh":"植物源食品、农产品 E 农药残留含量 液相色谱-串联质谱法（LC-MS-MS） Normy Procedury badawcze","technique_zh":"液相色谱-串联质谱法（LC-MS-MS）","test_object_zh":"植物源食品、农产品 E"},{"_id":"6a836ff8af14b9c0e7b1edd0","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Żywność, produkty rolne E","methodology":"Zawartość mikotoksyn","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną, z detekcją fluorescencyjną (HPLC-UV, HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną, z detekcją fluorescencyjną (HPLC-UV, HPLC-FLD)"],"computed":[],"activity":"Zawartość mikotoksyn\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną, z detekcją fluorescencyjną (HPLC-UV, HPLC-FLD)","reference":"Normy, Procedury Wydawnictwa Metodyczne PZH","norm_bases":["Normy, Procedury Wydawnictwa Metodyczne PZH"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Żywności; Pracownia Badań Chemicznych Żywności; Pracownia Analiz Instrumentalnych","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniona publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność, produkty rolne E Zawartość mikotoksyn\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną, z detekcją fluorescencyjną (HPLC-UV, HPLC-FLD) Normy, Procedury Wydawnictwa Metodyczne PZH Zywnosc, produkty rolne E Zawartosc mikotoksyn\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna, z detekcja fluorescencyjna (HPLC-UV, HPLC-FLD) Normy, Procedury Wydawnictwa Metodyczne PZH","categories":["food"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mycotoxin content","search_en":"Food, agricultural products E Mycotoxin content High-performance liquid chromatography with spectrophotometric detection, with fluorescence detection (HPLC-UV, HPLC-FLD) Normy, Procedury Wydawnictwa Metodyczne PZH","technique_en":"High-performance liquid chromatography with spectrophotometric detection, with fluorescence detection (HPLC-UV, HPLC-FLD)","test_object_en":"Food, agricultural products E","methodology_zh":"真菌毒素含量","search_zh":"真菌毒素含量 Normy, Procedury Wydawnictwa Metodyczne PZH"},{"_id":"6a836ff8af14b9c0e7b1edd1","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(5 – 70) mg/l Pt"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Barwa\nZakres (5 – 70) mg/l Pt\nMetoda wizualna","reference":"PN-EN ISO 7887:2012 + Ap1:2015-06 metoda D","norm_bases":["PN-EN ISO 7887:2012 + Ap1:2015-06 metoda D"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Wody i Gleby; Pracownia Badań Chemicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Barwa\nZakres (5 – 70) mg/l Pt\nMetoda wizualna PN-EN ISO 7887:2012 + Ap1:2015-06 metoda D Woda, Woda do spozycia przez ludzi Barwa\nZakres (5 – 70) mg/l Pt\nMetoda wizualna PN-EN ISO 7887:2012 + Ap1:2015-06 metoda D","categories":["water"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"(5 – 70) mg/l Pt"}],"search_en":"Water, Water intended for human consumption Colour Visual method Range PN-EN ISO 7887:2012 + Ap1:2015-06 metoda D","technique_en":"Visual method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(5 – 70) mg/l Pt"}],"search_zh":"水、生活饮用水 色度 目视法 范围 PN-EN ISO 7887:2012 + Ap1:2015-06 metoda D","technique_zh":"目视法","test_object_zh":"水、生活饮用水"},{"_id":"6a836ff8af14b9c0e7b1edd2","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(4 – 50) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Barwa\nZakres (4 – 50) mg/l Pt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012 + Ap1:2015-06 metoda C","norm_bases":["PN-EN ISO 7887:2012 + Ap1:2015-06 metoda C"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Wody i Gleby; Pracownia Badań Chemicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Barwa\nZakres (4 – 50) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 + Ap1:2015-06 metoda C Woda, Woda do spozycia przez ludzi Barwa\nZakres (4 – 50) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 + Ap1:2015-06 metoda C","categories":["water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"(4 – 50) mg/l Pt"}],"search_en":"Water, Water intended for human consumption Colour Spectrophotometric method Range PN-EN ISO 7887:2012 + Ap1:2015-06 metoda C","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(4 – 50) mg/l Pt"}],"search_zh":"水、生活饮用水 色度 分光光度法 范围 PN-EN ISO 7887:2012 + Ap1:2015-06 metoda C","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a836ff8af14b9c0e7b1edd3","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,10 – 40) NTU (FNU)"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,10 – 40) NTU (FNU)\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Wody i Gleby; Pracownia Badań Chemicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Mętność\nZakres (0,10 – 40) NTU (FNU)\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda, Woda do spozycia przez ludzi Metnosc\nZakres (0,10 – 40) NTU (FNU)\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,10 – 40) NTU (FNU)"}],"search_en":"Water, Water intended for human consumption Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09","technique_en":"Nephelometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,10 – 40) NTU (FNU)"}],"search_zh":"水、生活饮用水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"水、生活饮用水"},{"_id":"6a836ff8af14b9c0e7b1edd4","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Wody i Gleby; Pracownia Badań Chemicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, Woda do spozycia przez ludzi pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"search_en":"Water, Water intended for human consumption pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"水、生活饮用水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、生活饮用水"},{"_id":"6a836ff8af14b9c0e7b1edd5","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(10 – 3000) µS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (10 – 3000) µS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Wody i Gleby; Pracownia Badań Chemicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Przewodność elektryczna właściwa\nZakres (10 – 3000) µS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, Woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa\nZakres (10 – 3000) µS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(10 – 3000) µS/cm"}],"search_en":"Water, Water intended for human consumption Electrical conductivity Conductometric method Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(10 – 3000) µS/cm"}],"search_zh":"水、生活饮用水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、生活饮用水"},{"_id":"6a836ff8af14b9c0e7b1edd6","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie żelaza","parameters":[{"name":"Zakres","range":"(20 − 5000) µg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza\nZakres (20 − 5000) µg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001 + Ap1:2016-06","norm_bases":["PN-ISO 6332:2001 + Ap1:2016-06"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Wody i Gleby; Pracownia Badań Chemicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie żelaza\nZakres (20 − 5000) µg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001 + Ap1:2016-06 Woda, Woda do spozycia przez ludzi Stezenie zelaza\nZakres (20 − 5000) µg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001 + Ap1:2016-06","categories":["water"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Iron concentration","parameters_en":[{"name":"Range","range":"(20 − 5000) µg/l"}],"search_en":"Water, Water intended for human consumption Iron concentration Spectrophotometric method Range PN-ISO 6332:2001 + Ap1:2016-06","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"铁浓度","parameters_zh":[{"name":"范围","range":"(20 − 5000) µg/l"}],"search_zh":"水、生活饮用水 铁浓度 分光光度法 范围 PN-ISO 6332:2001 + Ap1:2016-06","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a836ff8af14b9c0e7b1edd7","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie manganu","parameters":[{"name":"Zakres","range":"(20,0 – 2000) µg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie manganu\nZakres (20,0 – 2000) µg/l\nMetoda spektrofotometryczna","reference":"PN-92/C-04590/03","norm_bases":["PN-92/C-04590/03"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Wody i Gleby; Pracownia Badań Chemicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie manganu\nZakres (20,0 – 2000) µg/l\nMetoda spektrofotometryczna PN-92/C-04590/03 Woda, Woda do spozycia przez ludzi Stezenie manganu\nZakres (20,0 – 2000) µg/l\nMetoda spektrofotometryczna PN-92/C-04590/03","categories":["water"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Manganese concentration","parameters_en":[{"name":"Range","range":"(20,0 – 2000) µg/l"}],"search_en":"Water, Water intended for human consumption Manganese concentration Spectrophotometric method Range PN-92/C-04590/03","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(20,0 – 2000) µg/l"}],"search_zh":"水、生活饮用水 锰浓度 分光光度法 范围 PN-92/C-04590/03","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a836ff8af14b9c0e7b1edd8","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)","parameters":[{"name":"Zakres","range":"(12,5 – 500) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (12,5 – 500) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Wody i Gleby; Pracownia Badań Chemicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (12,5 – 500) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999 Woda, Woda do spozycia przez ludzi Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna)\nZakres (12,5 – 500) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total content of calcium and magnesium (total hardness)","parameters_en":[{"name":"Range","range":"(12,5 – 500) mg/l CaCO3"}],"search_en":"Water, Water intended for human consumption Total content of calcium and magnesium (total hardness) Titrimetric method Range PN-ISO 6059:1999","technique_en":"Titrimetric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"钙与镁总量（总硬度）","parameters_zh":[{"name":"范围","range":"(12,5 – 500) mg/l CaCO3"}],"search_zh":"水、生活饮用水 钙与镁总量（总硬度） 滴定法 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"水、生活饮用水"},{"_id":"6a836ff8af14b9c0e7b1edd9","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie wapnia","parameters":[{"name":"Zakres","range":"(5 – 200) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie wapnia\nZakres (5 – 200) mg/l\nMetoda miareczkowa","reference":"PN-ISO 6058:1999","norm_bases":["PN-ISO 6058:1999"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Wody i Gleby; Pracownia Badań Chemicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie wapnia\nZakres (5 – 200) mg/l\nMetoda miareczkowa PN-ISO 6058:1999 Woda, Woda do spozycia przez ludzi Stezenie wapnia\nZakres (5 – 200) mg/l\nMetoda miareczkowa PN-ISO 6058:1999","categories":["water"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Calcium concentration","parameters_en":[{"name":"Range","range":"(5 – 200) mg/l"}],"search_en":"Water, Water intended for human consumption Calcium concentration Titrimetric method Range PN-ISO 6058:1999","technique_en":"Titrimetric method","test_object_en":"Water, Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(5 – 200) mg/l"}],"search_zh":"水、生活饮用水 钙浓度 滴定法 范围 PN-ISO 6058:1999","technique_zh":"滴定法","test_object_zh":"水、生活饮用水","methodology_zh":"钙浓度"},{"_id":"6a836ff8af14b9c0e7b1edda","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie magnezu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie magnezu (z obliczeń)","reference":"PN-C-04554-4:1999 Załącznik A","norm_bases":["PN-C-04554-4:1999 Załącznik A"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Wody i Gleby; Pracownia Badań Chemicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie magnezu (z obliczeń) PN-C-04554-4:1999 Załącznik A Woda, Woda do spozycia przez ludzi Stezenie magnezu (z obliczen) PN-C-04554-4:1999 Zalacznik A","categories":["water"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnesium concentration (calculated)","search_en":"Water, Water intended for human consumption Magnesium concentration (calculated) PN-C-04554-4:1999 Załącznik A","test_object_en":"Water, Water intended for human consumption","search_zh":"水、生活饮用水 镁浓度（计算值） PN-C-04554-4:1999 Załącznik A","test_object_zh":"水、生活饮用水","methodology_zh":"镁浓度（计算值）"},{"_id":"6a836ff8af14b9c0e7b1eddb","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie azotynów, azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,010 – 1,00) mg/l NO2"},{"name":"(0,003 − 0,30) mg/l NNO2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotynów, azotu azotynowego\nZakres:\nZakres (0,010 – 1,00) mg/l NO2\n(0,003 − 0,30) mg/l NNO2\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Wody i Gleby; Pracownia Badań Chemicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie azotynów, azotu azotynowego\nZakres:\nZakres (0,010 – 1,00) mg/l NO2\n(0,003 − 0,30) mg/l NNO2\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, Woda do spozycia przez ludzi Stezenie azotynow, azotu azotynowego\nZakres:\nZakres (0,010 – 1,00) mg/l NO2\n(0,003 − 0,30) mg/l NNO2\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite, nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,010 – 1,00) mg/l NO2"},{"name":"(0,003 − 0,30) mg/l NNO2"}],"search_en":"Water, Water intended for human consumption Nitrite, nitrite nitrogen concentration Spectrophotometric method Range (0,003 − 0,30) mg/l NNO2 PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,010 – 1,00) mg/l NO2"},{"name":"(0,003 − 0,30) mg/l NNO2"}],"search_zh":"水、生活饮用水 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a836ff8af14b9c0e7b1eddc","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie azotanów, azotu azotanowego","parameters":[{"name":"Zakres","range":"(2,0 – 80,0) mg/l NO3"},{"name":"(0,46 − 18,0) mg/l NNO3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotanów, azotu azotanowego\nZakres:\nZakres (2,0 – 80,0) mg/l NO3\n(0,46 − 18,0) mg/l NNO3\nMetoda spektrofotometryczna","reference":"PN-82/C-04576.08","norm_bases":["PN-82/C-04576.08"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Wody i Gleby; Pracownia Badań Chemicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie azotanów, azotu azotanowego\nZakres:\nZakres (2,0 – 80,0) mg/l NO3\n(0,46 − 18,0) mg/l NNO3\nMetoda spektrofotometryczna PN-82/C-04576.08 Woda, Woda do spozycia przez ludzi Stezenie azotanow, azotu azotanowego\nZakres:\nZakres (2,0 – 80,0) mg/l NO3\n(0,46 − 18,0) mg/l NNO3\nMetoda spektrofotometryczna PN-82/C-04576.08","categories":["water"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate, nitrate nitrogen concentration","parameters_en":[{"name":"Range","range":"(2,0 – 80,0) mg/l NO3"},{"name":"(0,46 − 18,0) mg/l NNO3"}],"search_en":"Water, Water intended for human consumption Nitrate, nitrate nitrogen concentration Spectrophotometric method Range (0,46 − 18,0) mg/l NNO3 PN-82/C-04576.08","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(2,0 – 80,0) mg/l NO3"},{"name":"(0,46 − 18,0) mg/l NNO3"}],"search_zh":"水、生活饮用水 分光光度法 范围 PN-82/C-04576.08","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a836ff8af14b9c0e7b1eddd","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie anionów","parameters":[{"name":"fluorki","range":"(0,3 – 9,0) mg/l"},{"name":"chlorki","range":"(5,0 – 250) mg/l"},{"name":"azotyny","range":"(0,10 – 4,0) mg/l"},{"name":"azotany","range":"(1,0 – 50) mg/l"},{"name":"bromki","range":"(0,5 – 9,0) mg/l"},{"name":"fosforany","range":"(0,2 – 9,0) mg/l"},{"name":"siarczany","range":"(5,0 – 250) mg/l"}],"technique":"Metoda chromatografii jonowej (IC)","techniques":["Metoda chromatografii jonowej (IC)"],"computed":[],"activity":"Stężenie anionów\nZakres:\nfluorki (0,3 – 9,0) mg/l\nchlorki (5,0 – 250) mg/l\nazotyny (0,10 – 4,0) mg/l\nazotany (1,0 – 50) mg/l\nbromki (0,5 – 9,0) mg/l\nfosforany (0,2 – 9,0) mg/l\nsiarczany (5,0 – 250) mg/l\nMetoda chromatografii jonowej (IC)","reference":"PN-EN ISO 10304-1:2009","norm_bases":["PN-EN ISO 10304-1:2009"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Wody i Gleby; Pracownia Badań Chemicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie anionów\nZakres:\nfluorki (0,3 – 9,0) mg/l\nchlorki (5,0 – 250) mg/l\nazotyny (0,10 – 4,0) mg/l\nazotany (1,0 – 50) mg/l\nbromki (0,5 – 9,0) mg/l\nfosforany (0,2 – 9,0) mg/l\nsiarczany (5,0 – 250) mg/l\nMetoda chromatografii jonowej (IC) PN-EN ISO 10304-1:2009 Woda, Woda do spozycia przez ludzi Stezenie anionow\nZakres:\nfluorki (0,3 – 9,0) mg/l\nchlorki (5,0 – 250) mg/l\nazotyny (0,10 – 4,0) mg/l\nazotany (1,0 – 50) mg/l\nbromki (0,5 – 9,0) mg/l\nfosforany (0,2 – 9,0) mg/l\nsiarczany (5,0 – 250) mg/l\nMetoda chromatografii jonowej (IC) PN-EN ISO 10304-1:2009","categories":["water"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Anion concentrations","parameters_en":[{"name":"fluorides","range":"(0,3 – 9,0) mg/l"},{"name":"chlorides","range":"(5,0 – 250) mg/l"},{"name":"nitrites","range":"(0,10 – 4,0) mg/l"},{"name":"nitrates","range":"(1,0 – 50) mg/l"},{"name":"bromides","range":"(0,5 – 9,0) mg/l"},{"name":"phosphates","range":"(0,2 – 9,0) mg/l"},{"name":"sulfates","range":"(5,0 – 250) mg/l"}],"search_en":"Water, Water intended for human consumption Anion concentrations Ion chromatography (IC) fluorides chlorides nitrites nitrates bromides phosphates sulfates PN-EN ISO 10304-1:2009","technique_en":"Ion chromatography (IC)","test_object_en":"Water, Water intended for human consumption","methodology_zh":"阴离子浓度","search_zh":"水、生活饮用水 阴离子浓度 离子色谱法（IC） 氟化物 氯化物 亚硝酸盐 硝酸盐 溴化物 磷酸盐 硫酸盐 PN-EN ISO 10304-1:2009","test_object_zh":"水、生活饮用水","parameters_zh":[{"name":"氟化物","range":"(0,3 – 9,0) mg/l"},{"name":"氯化物","range":"(5,0 – 250) mg/l"},{"name":"亚硝酸盐","range":"(0,10 – 4,0) mg/l"},{"name":"硝酸盐","range":"(1,0 – 50) mg/l"},{"name":"溴化物","range":"(0,5 – 9,0) mg/l"},{"name":"磷酸盐","range":"(0,2 – 9,0) mg/l"},{"name":"硫酸盐","range":"(5,0 – 250) mg/l"}],"technique_zh":"离子色谱法（IC）"},{"_id":"6a836ff8af14b9c0e7b1edde","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie jonu amonu, azotu amonowego","parameters":[{"name":"Zakres","range":"(0,05 – 1,10) mg/l NH4"},{"name":"Zakres","range":"(0,04 – 0,86) mg/l NNH4"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie jonu amonu, azotu amonowego\nZakres:\nZakres (0,05 – 1,10) mg/l NH4\nZakres (0,04 – 0,86) mg/l NNH4\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Wody i Gleby; Pracownia Badań Chemicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie jonu amonu, azotu amonowego\nZakres:\nZakres (0,05 – 1,10) mg/l NH4\nZakres (0,04 – 0,86) mg/l NNH4\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, Woda do spozycia przez ludzi Stezenie jonu amonu, azotu amonowego\nZakres:\nZakres (0,05 – 1,10) mg/l NH4\nZakres (0,04 – 0,86) mg/l NNH4\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium ion, ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,05 – 1,10) mg/l NH4"},{"name":"Range","range":"(0,04 – 0,86) mg/l NNH4"}],"search_en":"Water, Water intended for human consumption Ammonium ion, ammonium nitrogen concentration Spectrophotometric method Range Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,05 – 1,10) mg/l NH4"},{"name":"范围","range":"(0,04 – 0,86) mg/l NNH4"}],"search_zh":"水、生活饮用水 分光光度法 范围 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a836ff8af14b9c0e7b1eddf","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Indeks nadmanganianowy","parameters":[{"name":"Zakres","range":"(0,5 – 10,0) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Indeks nadmanganianowy\nZakres (0,5 – 10,0) mg/l\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Wody i Gleby; Pracownia Badań Chemicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Indeks nadmanganianowy\nZakres (0,5 – 10,0) mg/l\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda, Woda do spozycia przez ludzi Indeks nadmanganianowy\nZakres (0,5 – 10,0) mg/l\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Permanganate index","parameters_en":[{"name":"Range","range":"(0,5 – 10,0) mg/l"}],"search_en":"Water, Water intended for human consumption Permanganate index Titrimetric method Range PN-EN ISO 8467:2001","technique_en":"Titrimetric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"高锰酸盐指数","parameters_zh":[{"name":"范围","range":"(0,5 – 10,0) mg/l"}],"search_zh":"水、生活饮用水 高锰酸盐指数 滴定法 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"水、生活饮用水"},{"_id":"6a836ff8af14b9c0e7b1ede0","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie ogólnego węgla organicznego (TOC)","parameters":[{"name":"Zakres","range":"(0,80 – 18,0) mg/l"}],"technique":"Metoda spektrometrii w podczerwieni (IR)","techniques":["Metoda spektrometrii w podczerwieni (IR)"],"computed":[],"activity":"Stężenie ogólnego węgla organicznego (TOC)\nZakres (0,80 – 18,0) mg/l\nMetoda spektrometrii w podczerwieni (IR)","reference":"PN-EN 1484:1999","norm_bases":["PN-EN 1484:1999"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Wody i Gleby; Pracownia Badań Chemicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie ogólnego węgla organicznego (TOC)\nZakres (0,80 – 18,0) mg/l\nMetoda spektrometrii w podczerwieni (IR) PN-EN 1484:1999 Woda, Woda do spozycia przez ludzi Stezenie ogolnego wegla organicznego (TOC)\nZakres (0,80 – 18,0) mg/l\nMetoda spektrometrii w podczerwieni (IR) PN-EN 1484:1999","categories":["water"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total organic carbon (TOC) concentration","parameters_en":[{"name":"Range","range":"(0,80 – 18,0) mg/l"}],"search_en":"Water, Water intended for human consumption Total organic carbon (TOC) concentration Infrared spectrometry method (IR) Range PN-EN 1484:1999","technique_en":"Infrared spectrometry method (IR)","test_object_en":"Water, Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,80 – 18,0) mg/l"}],"search_zh":"水、生活饮用水 总有机碳（TOC）浓度 红外光谱法（IR） 范围 PN-EN 1484:1999","test_object_zh":"水、生活饮用水","technique_zh":"红外光谱法（IR）","methodology_zh":"总有机碳（TOC）浓度"},{"_id":"6a836ff8af14b9c0e7b1ede1","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie anionów","parameters":[{"name":"Chlorany","range":"(60,0 – 400,0) µg/l"},{"name":"Chloryny","range":"(60,0 – 400,0) µg/l"},{"name":"Suma stężeń chloranów i chlorynów (z obliczeń)"}],"technique":"Metoda chromatografii jonowej (IC)","techniques":["Metoda chromatografii jonowej (IC)"],"computed":[],"activity":"Stężenie anionów\nZakres:\nChlorany (60,0 – 400,0) µg/l\nChloryny (60,0 – 400,0) µg/l\nSuma stężeń chloranów i chlorynów (z obliczeń)\nMetoda chromatografii jonowej (IC)","reference":"PN-EN ISO 10304-4:2022-08","norm_bases":["PN-EN ISO 10304-4:2022-08"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Wody i Gleby; Pracownia Badań Chemicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie anionów\nZakres:\nChlorany (60,0 – 400,0) µg/l\nChloryny (60,0 – 400,0) µg/l\nSuma stężeń chloranów i chlorynów (z obliczeń)\nMetoda chromatografii jonowej (IC) PN-EN ISO 10304-4:2022-08 Woda, Woda do spozycia przez ludzi Stezenie anionow\nZakres:\nChlorany (60,0 – 400,0) µg/l\nChloryny (60,0 – 400,0) µg/l\nSuma stezen chloranow i chlorynow (z obliczen)\nMetoda chromatografii jonowej (IC) PN-EN ISO 10304-4:2022-08","categories":["water"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Anion concentrations","parameters_en":[{"name":"Chlorates","range":"(60,0 – 400,0) µg/l"},{"name":"Chlorites","range":"(60,0 – 400,0) µg/l"},{"name":"Sum of chlorate and chlorite concentrations (calculated)"}],"search_en":"Water, Water intended for human consumption Anion concentrations Ion chromatography (IC) Chlorates Chlorites Sum of chlorate and chlorite concentrations (calculated) PN-EN ISO 10304-4:2022-08","technique_en":"Ion chromatography (IC)","test_object_en":"Water, Water intended for human consumption","methodology_zh":"阴离子浓度","search_zh":"水、生活饮用水 阴离子浓度 离子色谱法（IC） 氯酸盐 亚氯酸盐 PN-EN ISO 10304-4:2022-08","test_object_zh":"水、生活饮用水","technique_zh":"离子色谱法（IC）","parameters_zh":[{"name":"氯酸盐","range":"(60,0 – 400,0) µg/l"},{"name":"亚氯酸盐","range":"(60,0 – 400,0) µg/l"},{"name":"Suma stężeń chloranów i chlorynów (z obliczeń)"}]},{"_id":"6a836ff8af14b9c0e7b1ede2","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie bromianów","parameters":[{"name":"Zakres","range":"(3,0 – 40,0) µg/l"}],"technique":"Metoda chromatografii jonowej (IC)","techniques":["Metoda chromatografii jonowej (IC)"],"computed":[],"activity":"Stężenie bromianów\nZakres (3,0 – 40,0) µg/l\nMetoda chromatografii jonowej (IC)","reference":"PN-EN ISO 15061:2003","norm_bases":["PN-EN ISO 15061:2003"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Wody i Gleby; Pracownia Badań Chemicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie bromianów\nZakres (3,0 – 40,0) µg/l\nMetoda chromatografii jonowej (IC) PN-EN ISO 15061:2003 Woda, Woda do spozycia przez ludzi Stezenie bromianow\nZakres (3,0 – 40,0) µg/l\nMetoda chromatografii jonowej (IC) PN-EN ISO 15061:2003","categories":["water"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Bromate concentration","parameters_en":[{"name":"Range","range":"(3,0 – 40,0) µg/l"}],"search_en":"Water, Water intended for human consumption Bromate concentration Ion chromatography (IC) Range PN-EN ISO 15061:2003","technique_en":"Ion chromatography (IC)","test_object_en":"Water, Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(3,0 – 40,0) µg/l"}],"search_zh":"水、生活饮用水 溴酸盐浓度 离子色谱法（IC） 范围 PN-EN ISO 15061:2003","test_object_zh":"水、生活饮用水","technique_zh":"离子色谱法（IC）","methodology_zh":"溴酸盐浓度"},{"_id":"6a836ff8af14b9c0e7b1ede3","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie cyjanków ogólnych","parameters":[{"name":"Zakres","range":"(10-90) µg/l"}],"technique":"Metoda wstrzykowej analizy przepływowej (FIA) z detekcją spektrofotometryczną","techniques":["Metoda wstrzykowej analizy przepływowej (FIA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie cyjanków ogólnych\nZakres (10-90) µg/l\nMetoda wstrzykowej analizy przepływowej (FIA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 14403-1:2012","norm_bases":["PN-EN ISO 14403-1:2012"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Wody i Gleby; Pracownia Badań Chemicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie cyjanków ogólnych\nZakres (10-90) µg/l\nMetoda wstrzykowej analizy przepływowej (FIA) z detekcją spektrofotometryczną PN-EN ISO 14403-1:2012 Woda, Woda do spozycia przez ludzi Stezenie cyjankow ogolnych\nZakres (10-90) µg/l\nMetoda wstrzykowej analizy przeplywowej (FIA) z detekcja spektrofotometryczna PN-EN ISO 14403-1:2012","categories":["water"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total cyanide concentration","parameters_en":[{"name":"Range","range":"(10-90) µg/l"}],"search_en":"Water, Water intended for human consumption Total cyanide concentration Flow injection analysis (FIA) with spectrophotometric detection Range PN-EN ISO 14403-1:2012","technique_en":"Flow injection analysis (FIA) with spectrophotometric detection","test_object_en":"Water, Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(10-90) µg/l"}],"search_zh":"水、生活饮用水 总氰化物浓度 流动注射分析（FIA）分光光度检测法 范围 PN-EN ISO 14403-1:2012","test_object_zh":"水、生活饮用水","methodology_zh":"总氰化物浓度","technique_zh":"流动注射分析（FIA）分光光度检测法"},{"_id":"6a836ff8af14b9c0e7b1ede4","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Obecność obcego zapachu","parameters":[],"technique":"Metoda jakościowa","techniques":["Metoda jakościowa"],"computed":[],"activity":"Obecność obcego zapachu\nMetoda jakościowa","reference":"PN-EN 1622:2006","norm_bases":["PN-EN 1622:2006"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Wody i Gleby; Pracownia Badań Chemicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Obecność obcego zapachu\nMetoda jakościowa PN-EN 1622:2006 Woda do spozycia przez ludzi Obecnosc obcego zapachu\nMetoda jakosciowa PN-EN 1622:2006","categories":["water"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of foreign odour","search_en":"Water intended for human consumption Presence of foreign odour Qualitative method PN-EN 1622:2006","technique_en":"Qualitative method","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 异味的检出 定性法 PN-EN 1622:2006","test_object_zh":"生活饮用水","technique_zh":"定性法","methodology_zh":"异味的检出"},{"_id":"6a836ff8af14b9c0e7b1ede5","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba progowa zapachu (TON)","parameters":[{"name":"Zakres","range":"1-4"}],"technique":"Metoda uproszczona pełna, parzysta, wybór niewymuszony","techniques":["Metoda uproszczona pełna, parzysta, wybór niewymuszony"],"computed":[],"activity":"Liczba progowa zapachu (TON)\nZakres 1-4\nMetoda uproszczona pełna, parzysta, wybór niewymuszony","reference":"PN-EN 1622:2006","norm_bases":["PN-EN 1622:2006"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Wody i Gleby; Pracownia Badań Chemicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba progowa zapachu (TON)\nZakres 1-4\nMetoda uproszczona pełna, parzysta, wybór niewymuszony PN-EN 1622:2006 Woda do spozycia przez ludzi Liczba progowa zapachu (TON)\nZakres 1-4\nMetoda uproszczona pelna, parzysta, wybor niewymuszony PN-EN 1622:2006","categories":["water"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Odour threshold number (TON)","parameters_en":[{"name":"Range","range":"1-4"}],"search_en":"Water intended for human consumption Odour threshold number (TON) Range PN-EN 1622:2006","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"1-4"}],"search_zh":"生活饮用水 嗅阈值（TON） 范围 PN-EN 1622:2006","test_object_zh":"生活饮用水","methodology_zh":"嗅阈值（TON）"},{"_id":"6a836ff8af14b9c0e7b1ede6","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Obecność obcego smaku","parameters":[],"technique":"Metoda Jakościowa","techniques":["Metoda Jakościowa"],"computed":[],"activity":"Obecność obcego smaku\nMetoda Jakościowa","reference":"PN-EN 1622:2006","norm_bases":["PN-EN 1622:2006"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Wody i Gleby; Pracownia Badań Chemicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Obecność obcego smaku\nMetoda Jakościowa PN-EN 1622:2006 Woda do spozycia przez ludzi Obecnosc obcego smaku\nMetoda Jakosciowa PN-EN 1622:2006","categories":["water"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of foreign taste","search_en":"Water intended for human consumption Presence of foreign taste PN-EN 1622:2006","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 异味（口感）的检出 PN-EN 1622:2006","test_object_zh":"生活饮用水","methodology_zh":"异味（口感）的检出"},{"_id":"6a836ff8af14b9c0e7b1ede7","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba progowa smaku (TFN)","parameters":[{"name":"Zakres","range":"1-4"}],"technique":"Metoda uproszczona pełna, parzysta, wybór niewymuszony","techniques":["Metoda uproszczona pełna, parzysta, wybór niewymuszony"],"computed":[],"activity":"Liczba progowa smaku (TFN)\nZakres 1-4\nMetoda uproszczona pełna, parzysta, wybór niewymuszony","reference":"PN-EN 1622:2006","norm_bases":["PN-EN 1622:2006"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Wody i Gleby; Pracownia Badań Chemicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba progowa smaku (TFN)\nZakres 1-4\nMetoda uproszczona pełna, parzysta, wybór niewymuszony PN-EN 1622:2006 Woda do spozycia przez ludzi Liczba progowa smaku (TFN)\nZakres 1-4\nMetoda uproszczona pelna, parzysta, wybor niewymuszony PN-EN 1622:2006","categories":["water"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Taste threshold number (TFN)","parameters_en":[{"name":"Range","range":"1-4"}],"search_en":"Water intended for human consumption Taste threshold number (TFN) Range PN-EN 1622:2006","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"1-4"}],"search_zh":"生活饮用水 味阈值（TFN） 范围 PN-EN 1622:2006","test_object_zh":"生活饮用水","methodology_zh":"味阈值（TFN）"},{"_id":"6a836ff8af14b9c0e7b1ede8","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie metali","parameters":[{"name":"rtęć","range":"(0,20-2,0) µg/l"},{"name":"chrom","range":"(5,0-200) µg/l"},{"name":"ołów","range":"(1,0-100) µg/l"},{"name":"srebro","range":"(0,0010-0,050) mg/l"},{"name":"selen","range":"(1,0-50) µg/l"},{"name":"arsen","range":"(1,0-100) µg/l"},{"name":"kadm","range":"(1,0-50) µg/l"},{"name":"antymon","range":"(1,0-50) µg/l"},{"name":"nikiel","range":"(5,0-200) µg/l"},{"name":"glin/aluminium","range":"(20-500) µg/l"},{"name":"bor","range":"(0,10-5,0) mg/l"},{"name":"miedź","range":"(0,0050-3,0) mg/l"},{"name":"cynk","range":"(0,20-5,0) mg/l"},{"name":"sód","range":"(1,0-300) mg/l"},{"name":"potas","range":"(1,0-100) mg/l"},{"name":"mangan","range":"(5,0-1000) µg/l"},{"name":"żelazo","range":"(20-3000) µg/l"},{"name":"magnez","range":"(2,0-150) mg/l"},{"name":"wapń","range":"(2,0-150) mg/l"},{"name":"uran","range":"(5,0-100) µg/l"}],"technique":"Metoda spektometrii mas z plazmą wzbudzaną indukcyjnie (ICP-MS)","techniques":["Metoda spektometrii mas z plazmą wzbudzaną indukcyjnie (ICP-MS)"],"computed":[],"activity":"Stężenie metali\nZakres:\nrtęć (0,20-2,0) µg/l\nchrom (5,0-200) µg/l\nołów (1,0-100) µg/l\nsrebro (0,0010-0,050) mg/l\nselen (1,0-50) µg/l\narsen (1,0-100) µg/l\nkadm (1,0-50) µg/l\nantymon (1,0-50) µg/l\nnikiel (5,0-200) µg/l\nglin/aluminium (20-500) µg/l\nbor (0,10-5,0) mg/l\nmiedź (0,0050-3,0) mg/l\ncynk (0,20-5,0) mg/l\nsód (1,0-300) mg/l\npotas (1,0-100) mg/l\nmangan (5,0-1000) µg/l\nżelazo (20-3000) µg/l\nmagnez (2,0-150) mg/l\nwapń (2,0-150) mg/l\nuran (5,0-100) µg/l\nMetoda spektometrii mas z plazmą wzbudzaną indukcyjnie (ICP-MS)","reference":"PN-EN ISO 17294-2:2024-04","norm_bases":["PN-EN ISO 17294-2:2024-04"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Wody i Gleby; Pracownia Badań Chemicznych Wody; Pracownia Analiz Instrumentalnych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie metali\nZakres:\nrtęć (0,20-2,0) µg/l\nchrom (5,0-200) µg/l\nołów (1,0-100) µg/l\nsrebro (0,0010-0,050) mg/l\nselen (1,0-50) µg/l\narsen (1,0-100) µg/l\nkadm (1,0-50) µg/l\nantymon (1,0-50) µg/l\nnikiel (5,0-200) µg/l\nglin/aluminium (20-500) µg/l\nbor (0,10-5,0) mg/l\nmiedź (0,0050-3,0) mg/l\ncynk (0,20-5,0) mg/l\nsód (1,0-300) mg/l\npotas (1,0-100) mg/l\nmangan (5,0-1000) µg/l\nżelazo (20-3000) µg/l\nmagnez (2,0-150) mg/l\nwapń (2,0-150) mg/l\nuran (5,0-100) µg/l\nMetoda spektometrii mas z plazmą wzbudzaną indukcyjnie (ICP-MS) PN-EN ISO 17294-2:2024-04 Woda, Woda do spozycia przez ludzi Stezenie metali\nZakres:\nrtec (0,20-2,0) µg/l\nchrom (5,0-200) µg/l\nolow (1,0-100) µg/l\nsrebro (0,0010-0,050) mg/l\nselen (1,0-50) µg/l\narsen (1,0-100) µg/l\nkadm (1,0-50) µg/l\nantymon (1,0-50) µg/l\nnikiel (5,0-200) µg/l\nglin/aluminium (20-500) µg/l\nbor (0,10-5,0) mg/l\nmiedz (0,0050-3,0) mg/l\ncynk (0,20-5,0) mg/l\nsod (1,0-300) mg/l\npotas (1,0-100) mg/l\nmangan (5,0-1000) µg/l\nzelazo (20-3000) µg/l\nmagnez (2,0-150) mg/l\nwapn (2,0-150) mg/l\nuran (5,0-100) µg/l\nMetoda spektometrii mas z plazma wzbudzana indukcyjnie (ICP-MS) PN-EN ISO 17294-2:2024-04","categories":["materials","water"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Metal concentrations","parameters_en":[{"name":"mercury","range":"(0,20-2,0) µg/l"},{"name":"chromium","range":"(5,0-200) µg/l"},{"name":"lead","range":"(1,0-100) µg/l"},{"name":"silver","range":"(0,0010-0,050) mg/l"},{"name":"selenium","range":"(1,0-50) µg/l"},{"name":"arsenic","range":"(1,0-100) µg/l"},{"name":"cadmium","range":"(1,0-50) µg/l"},{"name":"antimony","range":"(1,0-50) µg/l"},{"name":"nickel","range":"(5,0-200) µg/l"},{"name":"glin/aluminium","range":"(20-500) µg/l"},{"name":"boron","range":"(0,10-5,0) mg/l"},{"name":"copper","range":"(0,0050-3,0) mg/l"},{"name":"zinc","range":"(0,20-5,0) mg/l"},{"name":"sodium","range":"(1,0-300) mg/l"},{"name":"potassium","range":"(1,0-100) mg/l"},{"name":"manganese","range":"(5,0-1000) µg/l"},{"name":"iron","range":"(20-3000) µg/l"},{"name":"magnesium","range":"(2,0-150) mg/l"},{"name":"calcium","range":"(2,0-150) mg/l"},{"name":"uranium","range":"(5,0-100) µg/l"}],"search_en":"Water, Water intended for human consumption Metal concentrations Inductively coupled plasma mass spectrometry method (ICP-MS) mercury chromium lead silver selenium arsenic cadmium antimony nickel boron copper zinc sodium potassium manganese iron magnesium calcium uranium PN-EN ISO 17294-2:2024-04","technique_en":"Inductively coupled plasma mass spectrometry method (ICP-MS)","test_object_en":"Water, Water intended for human consumption","methodology_zh":"金属浓度","parameters_zh":[{"name":"汞","range":"(0,20-2,0) µg/l"},{"name":"铬","range":"(5,0-200) µg/l"},{"name":"铅","range":"(1,0-100) µg/l"},{"name":"银","range":"(0,0010-0,050) mg/l"},{"name":"硒","range":"(1,0-50) µg/l"},{"name":"砷","range":"(1,0-100) µg/l"},{"name":"镉","range":"(1,0-50) µg/l"},{"name":"锑","range":"(1,0-50) µg/l"},{"name":"镍","range":"(5,0-200) µg/l"},{"name":"glin/aluminium","range":"(20-500) µg/l"},{"name":"硼","range":"(0,10-5,0) mg/l"},{"name":"铜","range":"(0,0050-3,0) mg/l"},{"name":"锌","range":"(0,20-5,0) mg/l"},{"name":"钠","range":"(1,0-300) mg/l"},{"name":"钾","range":"(1,0-100) mg/l"},{"name":"锰","range":"(5,0-1000) µg/l"},{"name":"铁","range":"(20-3000) µg/l"},{"name":"镁","range":"(2,0-150) mg/l"},{"name":"钙","range":"(2,0-150) mg/l"},{"name":"铀","range":"(5,0-100) µg/l"}],"search_zh":"水、生活饮用水 金属浓度 汞 铬 铅 银 硒 砷 镉 锑 镍 硼 铜 锌 钠 钾 锰 铁 镁 钙 铀 PN-EN ISO 17294-2:2024-04","test_object_zh":"水、生活饮用水"},{"_id":"6a836ff8af14b9c0e7b1ede9","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie wielopierścieniowych węglowodorów aromatycznych","parameters":[{"name":"benzo/a/piren","range":"(0,002 – 0,025) µg/l"},{"name":"benzo/b/fluoranten","range":"(0,005 – 0,050) µg/l"},{"name":"benzo/k/fluoranten","range":"(0,005 – 0,050) µg/l"},{"name":"benzo/g,h,i/perylen","range":"(0,005 – 0,050) µg/l"},{"name":"indeno/1,2,3-c,d/piren","range":"(0,005 – 0,050) µg/l"},{"name":"Suma stężeń WWA","range":"(benzo/b/fluoranten benzo/k/fluoranten benzo/g,h,i/perylen indeno/1,2,3-c,d/piren)"},{"name":"(z obliczeń)"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Stężenie wielopierścieniowych węglowodorów aromatycznych\nZakres:\nbenzo/a/piren (0,002 – 0,025) µg/l\nbenzo/b/fluoranten (0,005 – 0,050) µg/l\nbenzo/k/fluoranten (0,005 – 0,050) µg/l\nbenzo/g,h,i/perylen (0,005 – 0,050) µg/l\nindeno/1,2,3-c,d/piren (0,005 – 0,050) µg/l\nSuma stężeń WWA (benzo/b/fluoranten benzo/k/fluoranten benzo/g,h,i/perylen indeno/1,2,3-c,d/piren)\n(z obliczeń)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"PB WG,AP-09 wydanie 6 z dnia 04.01.2021 r.","norm_bases":["PB WG,AP-09 wydanie 6 z dnia 04.01.2021 r."],"lab_section":"Dział Laboratoryjny/ Oddział Badania Wody i Gleby; Pracownia Badań Chemicznych Wody; Pracownia Analiz Instrumentalnych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie wielopierścieniowych węglowodorów aromatycznych\nZakres:\nbenzo/a/piren (0,002 – 0,025) µg/l\nbenzo/b/fluoranten (0,005 – 0,050) µg/l\nbenzo/k/fluoranten (0,005 – 0,050) µg/l\nbenzo/g,h,i/perylen (0,005 – 0,050) µg/l\nindeno/1,2,3-c,d/piren (0,005 – 0,050) µg/l\nSuma stężeń WWA (benzo/b/fluoranten benzo/k/fluoranten benzo/g,h,i/perylen indeno/1,2,3-c,d/piren)\n(z obliczeń)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) PB WG,AP-09 wydanie 6 z dnia 04.01.2021 r. Woda, Woda do spozycia przez ludzi Stezenie wielopierscieniowych weglowodorow aromatycznych\nZakres:\nbenzo/a/piren (0,002 – 0,025) µg/l\nbenzo/b/fluoranten (0,005 – 0,050) µg/l\nbenzo/k/fluoranten (0,005 – 0,050) µg/l\nbenzo/g,h,i/perylen (0,005 – 0,050) µg/l\nindeno/1,2,3-c,d/piren (0,005 – 0,050) µg/l\nSuma stezen WWA (benzo/b/fluoranten benzo/k/fluoranten benzo/g,h,i/perylen indeno/1,2,3-c,d/piren)\n(z obliczen)\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) PB WG,AP-09 wydanie 6 z dnia 04.01.2021 r.","categories":["water"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of polycyclic aromatic hydrocarbons","parameters_en":[{"name":"benzo/a/pyrene","range":"(0,002 – 0,025) µg/l"},{"name":"benzo/b/fluoranthene","range":"(0,005 – 0,050) µg/l"},{"name":"benzo/k/fluoranthene","range":"(0,005 – 0,050) µg/l"},{"name":"benzo/g,h,i/perylene","range":"(0,005 – 0,050) µg/l"},{"name":"indeno/1,2,3-c,d/pyrene","range":"(0,005 – 0,050) µg/l"},{"name":"Sum of PAH concentrations","range":"(benzo/b/fluoranten benzo/k/fluoranten benzo/g,h,i/perylen indeno/1,2,3-c,d/piren)"},{"name":"(calculated)"}],"search_en":"Water, Water intended for human consumption Concentration of polycyclic aromatic hydrocarbons High-performance liquid chromatography with fluorescence detection (HPLC-FLD) benzo/a/pyrene benzo/b/fluoranthene benzo/k/fluoranthene benzo/g,h,i/perylene indeno/1,2,3-c,d/pyrene Sum of PAH concentrations (calculated) PB WG,AP-09 wydanie 6 z dnia 04.01.2021 r.","technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD)","test_object_en":"Water, Water intended for human consumption","parameters_zh":[{"name":"benzo/a/piren","range":"(0,002 – 0,025) µg/l"},{"name":"benzo/b/fluoranten","range":"(0,005 – 0,050) µg/l"},{"name":"benzo/k/fluoranten","range":"(0,005 – 0,050) µg/l"},{"name":"benzo/g,h,i/perylen","range":"(0,005 – 0,050) µg/l"},{"name":"indeno/1,2,3-c,d/piren","range":"(0,005 – 0,050) µg/l"},{"name":"Suma stężeń WWA","range":"(benzo/b/fluoranten benzo/k/fluoranten benzo/g,h,i/perylen indeno/1,2,3-c,d/piren)"},{"name":"（计算得出）"}],"search_zh":"水、生活饮用水 多环芳烃浓度 高效液相色谱-荧光检测法（HPLC-FLD） （计算得出） PB WG,AP-09 wydanie 6 z dnia 04.01.2021 r.","technique_zh":"高效液相色谱-荧光检测法（HPLC-FLD）","test_object_zh":"水、生活饮用水","methodology_zh":"多环芳烃浓度"},{"_id":"6a836ff8af14b9c0e7b1edea","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie lotnych związków organicznych (VOC)","parameters":[{"name":"Trichlorometan (Chloroform)","range":"(8,0-200) µg/l"},{"name":"Bromodichlorometan","range":"(8,0-200) µg/l"},{"name":"Dibromochlorometan","range":"(8,0-200) µg/l"},{"name":"Tribromometan","range":"(8,0-200) µg/l"},{"name":"Tetrachlorometan","range":"(0,90-18) µg/l"},{"name":"Trichloroeten","range":"(0,90-18) µg/l"},{"name":"Tetrachloroeten","range":"(0,90-18) µg/l"},{"name":"1,2-Dichloroetan","range":"(0,90-18) µg/l"},{"name":"Benzen","range":"(0,30 – 5,0) µg/l"},{"name":"Suma stężeń THM (trichlorometanu, bromodichlorometanu, dibromochlorometanu, tribromometanu) (z obliczeń)"},{"name":"Suma stężeń trichloroetenu i tetrachloroetenu (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z zastosowaniem techniki wyłapywania i wypłukiwania (Purge&Trap) z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z zastosowaniem techniki wyłapywania i wypłukiwania (Purge&Trap) z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Stężenie lotnych związków organicznych (VOC)\nZakres:\nTrichlorometan (Chloroform) (8,0-200) µg/l\nBromodichlorometan (8,0-200) µg/l\nDibromochlorometan (8,0-200) µg/l\nTribromometan (8,0-200) µg/l\nTetrachlorometan (0,90-18) µg/l\nTrichloroeten (0,90-18) µg/l\nTetrachloroeten (0,90-18) µg/l\n1,2-Dichloroetan (0,90-18) µg/l\nBenzen (0,30 – 5,0) µg/l\nSuma stężeń THM (trichlorometanu, bromodichlorometanu, dibromochlorometanu, tribromometanu) (z obliczeń)\nSuma stężeń trichloroetenu i tetrachloroetenu (z obliczeń)\nMetoda chromatografii gazowej z zastosowaniem techniki wyłapywania i wypłukiwania (Purge&Trap) z detekcją spektrometrią mas (GC-MS)","reference":"PN-EN ISO 15680:2008","norm_bases":["PN-EN ISO 15680:2008"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Wody i Gleby; Pracownia Badań Chemicznych Wody; Pracownia Analiz Instrumentalnych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie lotnych związków organicznych (VOC)\nZakres:\nTrichlorometan (Chloroform) (8,0-200) µg/l\nBromodichlorometan (8,0-200) µg/l\nDibromochlorometan (8,0-200) µg/l\nTribromometan (8,0-200) µg/l\nTetrachlorometan (0,90-18) µg/l\nTrichloroeten (0,90-18) µg/l\nTetrachloroeten (0,90-18) µg/l\n1,2-Dichloroetan (0,90-18) µg/l\nBenzen (0,30 – 5,0) µg/l\nSuma stężeń THM (trichlorometanu, bromodichlorometanu, dibromochlorometanu, tribromometanu) (z obliczeń)\nSuma stężeń trichloroetenu i tetrachloroetenu (z obliczeń)\nMetoda chromatografii gazowej z zastosowaniem techniki wyłapywania i wypłukiwania (Purge&Trap) z detekcją spektrometrią mas (GC-MS) PN-EN ISO 15680:2008 Woda, Woda do spozycia przez ludzi Stezenie lotnych zwiazkow organicznych (VOC)\nZakres:\nTrichlorometan (Chloroform) (8,0-200) µg/l\nBromodichlorometan (8,0-200) µg/l\nDibromochlorometan (8,0-200) µg/l\nTribromometan (8,0-200) µg/l\nTetrachlorometan (0,90-18) µg/l\nTrichloroeten (0,90-18) µg/l\nTetrachloroeten (0,90-18) µg/l\n1,2-Dichloroetan (0,90-18) µg/l\nBenzen (0,30 – 5,0) µg/l\nSuma stezen THM (trichlorometanu, bromodichlorometanu, dibromochlorometanu, tribromometanu) (z obliczen)\nSuma stezen trichloroetenu i tetrachloroetenu (z obliczen)\nMetoda chromatografii gazowej z zastosowaniem techniki wylapywania i wyplukiwania (Purge&Trap) z detekcja spektrometria mas (GC-MS) PN-EN ISO 15680:2008","categories":["water"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Volatile organic compound (VOC) concentration","parameters_en":[{"name":"Trichlorometan (Chloroform)","range":"(8,0-200) µg/l"},{"name":"Bromodichloromethane","range":"(8,0-200) µg/l"},{"name":"Dibromochloromethane","range":"(8,0-200) µg/l"},{"name":"Tribromomethane","range":"(8,0-200) µg/l"},{"name":"Tetrachloromethane","range":"(0,90-18) µg/l"},{"name":"Trichloroethene","range":"(0,90-18) µg/l"},{"name":"Tetrachloroethene","range":"(0,90-18) µg/l"},{"name":"1,2-Dichloroethane","range":"(0,90-18) µg/l"},{"name":"Benzene","range":"(0,30 – 5,0) µg/l"},{"name":"Suma stężeń THM (trichlorometanu, bromodichlorometanu, dibromochlorometanu, tribromometanu) (z obliczeń)"},{"name":"Sum of trichloroethene and tetrachloroethene concentrations (calculated)"}],"search_en":"Water, Water intended for human consumption Volatile organic compound (VOC) concentration Gas chromatography using the purge and trap technique (Purge&Trap) with mass spectrometry detection (GC-MS) Bromodichloromethane Dibromochloromethane Tribromomethane Tetrachloromethane Trichloroethene Tetrachloroethene 1,2-Dichloroethane Benzene Sum of trichloroethene and tetrachloroethene concentrations (calculated) PN-EN ISO 15680:2008","technique_en":"Gas chromatography using the purge and trap technique (Purge&Trap) with mass spectrometry detection (GC-MS)","test_object_en":"Water, Water intended for human consumption","search_zh":"水、生活饮用水 挥发性有机化合物（VOC）浓度 吹扫捕集气相色谱-质谱检测法（GC-MS） 一溴二氯甲烷 二溴一氯甲烷 三溴甲烷 四氯化碳 三氯乙烯 四氯乙烯 苯 PN-EN ISO 15680:2008","test_object_zh":"水、生活饮用水","parameters_zh":[{"name":"Trichlorometan (Chloroform)","range":"(8,0-200) µg/l"},{"name":"一溴二氯甲烷","range":"(8,0-200) µg/l"},{"name":"二溴一氯甲烷","range":"(8,0-200) µg/l"},{"name":"三溴甲烷","range":"(8,0-200) µg/l"},{"name":"四氯化碳","range":"(0,90-18) µg/l"},{"name":"三氯乙烯","range":"(0,90-18) µg/l"},{"name":"四氯乙烯","range":"(0,90-18) µg/l"},{"name":"1,2-Dichloroetan","range":"(0,90-18) µg/l"},{"name":"苯","range":"(0,30 – 5,0) µg/l"},{"name":"Suma stężeń THM (trichlorometanu, bromodichlorometanu, dibromochlorometanu, tribromometanu) (z obliczeń)"},{"name":"Suma stężeń trichloroetenu i tetrachloroetenu (z obliczeń)"}],"technique_zh":"吹扫捕集气相色谱-质谱检测法（GC-MS）","methodology_zh":"挥发性有机化合物（VOC）浓度"},{"_id":"6a836ff8af14b9c0e7b1edeb","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie benzenu","parameters":[{"name":"Zakres","range":"(0,3 – 3,0) μg/l"}],"technique":"Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID)","techniques":["Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID)"],"computed":[],"activity":"Stężenie benzenu\nZakres (0,3 – 3,0) μg/l\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID)","reference":"PN-ISO 11423-1:2002","norm_bases":["PN-ISO 11423-1:2002"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Wody i Gleby; Pracownia Badań Chemicznych Wody; Pracownia Analiz Instrumentalnych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie benzenu\nZakres (0,3 – 3,0) μg/l\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID) PN-ISO 11423-1:2002 Woda, Woda do spozycia przez ludzi Stezenie benzenu\nZakres (0,3 – 3,0) μg/l\nMetoda chromatografii gazowej z analiza fazy nadpowierzchniowej i detekcja plomieniowo-jonizacyjna (HS-GC-FID) PN-ISO 11423-1:2002","categories":["water"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Benzene concentration","parameters_en":[{"name":"Range","range":"(0,3 – 3,0) μg/l"}],"search_en":"Water, Water intended for human consumption Benzene concentration Headspace gas chromatography with flame ionization detection (HS-GC-FID) Range PN-ISO 11423-1:2002","technique_en":"Headspace gas chromatography with flame ionization detection (HS-GC-FID)","test_object_en":"Water, Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,3 – 3,0) μg/l"}],"search_zh":"水、生活饮用水 苯浓度 顶空气相色谱-火焰离子化检测法（HS-GC-FID） 范围 PN-ISO 11423-1:2002","test_object_zh":"水、生活饮用水","methodology_zh":"苯浓度","technique_zh":"顶空气相色谱-火焰离子化检测法（HS-GC-FID）"},{"_id":"6a836ff8af14b9c0e7b1edec","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie pestycydów","parameters":[{"name":"α–heksachlorocykloheksan (α–HCH)","range":"(0,025 – 0,180) µg/l"},{"name":"Heksachlorobenzen (HCB)","range":"(0,025 – 0,180) µg/l"},{"name":"β–heksachlorocykloheksan (β–HCH)","range":"(0,024 – 0,170) µg/l"},{"name":"lindan (γ–HCH)","range":"(0,025 – 0,180) µg/l"},{"name":"δ–heksachlorocykloheksan (δ–HCH)","range":"(0,025 – 0,180) µg/l"},{"name":"winklozolina","range":"(0,025 – 0,180) µg/l"},{"name":"heptachlor","range":"(0,008 – 0,050) µg/l"},{"name":"dichlofluanid","range":"(0,025 – 0,180) µg/l"},{"name":"aldryna","range":"(0,008 – 0,050) µg/l"},{"name":"tolilofluanid","range":"(0,025 – 0,180) µg/l"},{"name":"epoksyd heptachloru A","range":"(0,008 – 0,050) µg/l"},{"name":"epoksyd heptachloru B","range":"(0,008 – 0,050) µg/l"},{"name":"o, p’ - DDE","range":"(0,025 – 0,180) µg/l"},{"name":"p, p’ - DDE","range":"(0,025 – 0,180) µg/l"},{"name":"o, p’ - DDD","range":"(0,025 – 0,180) µg/l"},{"name":"dieldryna","range":"(0,008 – 0,050) µg/l"},{"name":"p, p’ - DDD","range":"(0,025 – 0,180) µg/l"},{"name":"o, p’ - DDT","range":"(0,027 – 0,190) µg/l"},{"name":"p, p’ - DDT","range":"(0,025 – 0,180) µg/l"},{"name":"bifentryna","range":"(0,025 – 0,180) µg/l"},{"name":"fenpropatryna","range":"(0,025 – 0,180) µg/l"},{"name":"λ–cyhalotryna","range":"(0,025 – 0,180) µg/l"},{"name":"fenarymol","range":"(0,025 – 0,180) µg/l"},{"name":"permetryna","range":"(0,025 – 0,180) µg/l"},{"name":"cypermetryna","range":"(0,025 – 0,180) µg/l"},{"name":"deltametryna","range":"(0,025 – 0,180) µg/l"},{"name":"Suma stężeń analizowanych pestycydów (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","techniques":["Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)"],"computed":[],"activity":"Stężenie pestycydów\nZakres:\nα–heksachlorocykloheksan (α–HCH) (0,025 – 0,180) µg/l\nHeksachlorobenzen (HCB) (0,025 – 0,180) µg/l\nβ–heksachlorocykloheksan (β–HCH) (0,024 – 0,170) µg/l\nlindan (γ–HCH) (0,025 – 0,180) µg/l\nδ–heksachlorocykloheksan (δ–HCH) (0,025 – 0,180) µg/l\nwinklozolina (0,025 – 0,180) µg/l\nheptachlor (0,008 – 0,050) µg/l\ndichlofluanid (0,025 – 0,180) µg/l\naldryna (0,008 – 0,050) µg/l\ntolilofluanid (0,025 – 0,180) µg/l\nepoksyd heptachloru A (0,008 – 0,050) µg/l\nepoksyd heptachloru B (0,008 – 0,050) µg/l\no, p’ - DDE (0,025 – 0,180) µg/l\np, p’ - DDE (0,025 – 0,180) µg/l\no, p’ - DDD (0,025 – 0,180) µg/l\ndieldryna (0,008 – 0,050) µg/l\np, p’ - DDD (0,025 – 0,180) µg/l\no, p’ - DDT (0,027 – 0,190) µg/l\np, p’ - DDT (0,025 – 0,180) µg/l\nbifentryna (0,025 – 0,180) µg/l\nfenpropatryna (0,025 – 0,180) µg/l\nλ–cyhalotryna (0,025 – 0,180) µg/l\nfenarymol (0,025 – 0,180) µg/l\npermetryna (0,025 – 0,180) µg/l\ncypermetryna (0,025 – 0,180) µg/l\ndeltametryna (0,025 – 0,180) µg/l\nSuma stężeń analizowanych pestycydów (z obliczeń)\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","reference":"PN-EN ISO 6468:2002","norm_bases":["PN-EN ISO 6468:2002"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Wody i Gleby; Pracownia Badań Chemicznych Wody; Pracownia Analiz Instrumentalnych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie pestycydów\nZakres:\nα–heksachlorocykloheksan (α–HCH) (0,025 – 0,180) µg/l\nHeksachlorobenzen (HCB) (0,025 – 0,180) µg/l\nβ–heksachlorocykloheksan (β–HCH) (0,024 – 0,170) µg/l\nlindan (γ–HCH) (0,025 – 0,180) µg/l\nδ–heksachlorocykloheksan (δ–HCH) (0,025 – 0,180) µg/l\nwinklozolina (0,025 – 0,180) µg/l\nheptachlor (0,008 – 0,050) µg/l\ndichlofluanid (0,025 – 0,180) µg/l\naldryna (0,008 – 0,050) µg/l\ntolilofluanid (0,025 – 0,180) µg/l\nepoksyd heptachloru A (0,008 – 0,050) µg/l\nepoksyd heptachloru B (0,008 – 0,050) µg/l\no, p’ - DDE (0,025 – 0,180) µg/l\np, p’ - DDE (0,025 – 0,180) µg/l\no, p’ - DDD (0,025 – 0,180) µg/l\ndieldryna (0,008 – 0,050) µg/l\np, p’ - DDD (0,025 – 0,180) µg/l\no, p’ - DDT (0,027 – 0,190) µg/l\np, p’ - DDT (0,025 – 0,180) µg/l\nbifentryna (0,025 – 0,180) µg/l\nfenpropatryna (0,025 – 0,180) µg/l\nλ–cyhalotryna (0,025 – 0,180) µg/l\nfenarymol (0,025 – 0,180) µg/l\npermetryna (0,025 – 0,180) µg/l\ncypermetryna (0,025 – 0,180) µg/l\ndeltametryna (0,025 – 0,180) µg/l\nSuma stężeń analizowanych pestycydów (z obliczeń)\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) PN-EN ISO 6468:2002 Woda, Woda do spozycia przez ludzi Stezenie pestycydow\nZakres:\nα–heksachlorocykloheksan (α–HCH) (0,025 – 0,180) µg/l\nHeksachlorobenzen (HCB) (0,025 – 0,180) µg/l\nβ–heksachlorocykloheksan (β–HCH) (0,024 – 0,170) µg/l\nlindan (γ–HCH) (0,025 – 0,180) µg/l\nδ–heksachlorocykloheksan (δ–HCH) (0,025 – 0,180) µg/l\nwinklozolina (0,025 – 0,180) µg/l\nheptachlor (0,008 – 0,050) µg/l\ndichlofluanid (0,025 – 0,180) µg/l\naldryna (0,008 – 0,050) µg/l\ntolilofluanid (0,025 – 0,180) µg/l\nepoksyd heptachloru A (0,008 – 0,050) µg/l\nepoksyd heptachloru B (0,008 – 0,050) µg/l\no, p’ - DDE (0,025 – 0,180) µg/l\np, p’ - DDE (0,025 – 0,180) µg/l\no, p’ - DDD (0,025 – 0,180) µg/l\ndieldryna (0,008 – 0,050) µg/l\np, p’ - DDD (0,025 – 0,180) µg/l\no, p’ - DDT (0,027 – 0,190) µg/l\np, p’ - DDT (0,025 – 0,180) µg/l\nbifentryna (0,025 – 0,180) µg/l\nfenpropatryna (0,025 – 0,180) µg/l\nλ–cyhalotryna (0,025 – 0,180) µg/l\nfenarymol (0,025 – 0,180) µg/l\npermetryna (0,025 – 0,180) µg/l\ncypermetryna (0,025 – 0,180) µg/l\ndeltametryna (0,025 – 0,180) µg/l\nSuma stezen analizowanych pestycydow (z obliczen)\nMetoda chromatografii gazowej z detekcja wychwytu elektronow (GC-ECD) PN-EN ISO 6468:2002","categories":["water"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Pesticide concentration","parameters_en":[{"name":"α–hexachlorocyclohexane (α–HCH)","range":"(0,025 – 0,180) µg/l"},{"name":"Hexachlorobenzene (HCB)","range":"(0,025 – 0,180) µg/l"},{"name":"β–hexachlorocyclohexane (β–HCH)","range":"(0,024 – 0,170) µg/l"},{"name":"lindane (γ–HCH)","range":"(0,025 – 0,180) µg/l"},{"name":"δ–hexachlorocyclohexane (δ–HCH)","range":"(0,025 – 0,180) µg/l"},{"name":"vinclozolin","range":"(0,025 – 0,180) µg/l"},{"name":"heptachlor","range":"(0,008 – 0,050) µg/l"},{"name":"dichlofluanid","range":"(0,025 – 0,180) µg/l"},{"name":"aldrin","range":"(0,008 – 0,050) µg/l"},{"name":"tolylfluanid","range":"(0,025 – 0,180) µg/l"},{"name":"heptachlor epoxide A","range":"(0,008 – 0,050) µg/l"},{"name":"heptachlor epoxide B","range":"(0,008 – 0,050) µg/l"},{"name":"o, p’ - DDE","range":"(0,025 – 0,180) µg/l"},{"name":"p, p’ - DDE","range":"(0,025 – 0,180) µg/l"},{"name":"o, p’ - DDD","range":"(0,025 – 0,180) µg/l"},{"name":"dieldrin","range":"(0,008 – 0,050) µg/l"},{"name":"p, p’ - DDD","range":"(0,025 – 0,180) µg/l"},{"name":"o, p’ - DDT","range":"(0,027 – 0,190) µg/l"},{"name":"p, p’ - DDT","range":"(0,025 – 0,180) µg/l"},{"name":"bifenthrin","range":"(0,025 – 0,180) µg/l"},{"name":"fenpropathrin","range":"(0,025 – 0,180) µg/l"},{"name":"λ–cyhalothrin","range":"(0,025 – 0,180) µg/l"},{"name":"fenarimol","range":"(0,025 – 0,180) µg/l"},{"name":"permethrin","range":"(0,025 – 0,180) µg/l"},{"name":"cypermethrin","range":"(0,025 – 0,180) µg/l"},{"name":"deltamethrin","range":"(0,025 – 0,180) µg/l"},{"name":"Sum of concentrations of the analysed pesticides (calculated)"}],"search_en":"Water, Water intended for human consumption Pesticide concentration Gas chromatography with electron capture detection (GC-ECD) α–hexachlorocyclohexane (α–HCH) Hexachlorobenzene (HCB) β–hexachlorocyclohexane (β–HCH) lindane (γ–HCH) δ–hexachlorocyclohexane (δ–HCH) vinclozolin heptachlor dichlofluanid aldrin tolylfluanid heptachlor epoxide A heptachlor epoxide B o, p’ - DDE p, p’ - DDE o, p’ - DDD dieldrin p, p’ - DDD o, p’ - DDT p, p’ - DDT bifenthrin fenpropathrin λ–cyhalothrin fenarimol permethrin cypermethrin deltamethrin Sum of concentrations of the analysed pesticides (calculated) PN-EN ISO 6468:2002","technique_en":"Gas chromatography with electron capture detection (GC-ECD)","test_object_en":"Water, Water intended for human consumption","methodology_zh":"农药浓度","search_zh":"水、生活饮用水 农药浓度 气相色谱-电子捕获检测法（GC-ECD） 六氯苯（HCB） 七氯 艾氏剂 狄氏剂 PN-EN ISO 6468:2002","technique_zh":"气相色谱-电子捕获检测法（GC-ECD）","test_object_zh":"水、生活饮用水","parameters_zh":[{"name":"α–heksachlorocykloheksan (α–HCH)","range":"(0,025 – 0,180) µg/l"},{"name":"六氯苯（HCB）","range":"(0,025 – 0,180) µg/l"},{"name":"β–heksachlorocykloheksan (β–HCH)","range":"(0,024 – 0,170) µg/l"},{"name":"lindan (γ–HCH)","range":"(0,025 – 0,180) µg/l"},{"name":"δ–heksachlorocykloheksan (δ–HCH)","range":"(0,025 – 0,180) µg/l"},{"name":"winklozolina","range":"(0,025 – 0,180) µg/l"},{"name":"七氯","range":"(0,008 – 0,050) µg/l"},{"name":"dichlofluanid","range":"(0,025 – 0,180) µg/l"},{"name":"艾氏剂","range":"(0,008 – 0,050) µg/l"},{"name":"tolilofluanid","range":"(0,025 – 0,180) µg/l"},{"name":"epoksyd heptachloru A","range":"(0,008 – 0,050) µg/l"},{"name":"epoksyd heptachloru B","range":"(0,008 – 0,050) µg/l"},{"name":"o, p’ - DDE","range":"(0,025 – 0,180) µg/l"},{"name":"p, p’ - DDE","range":"(0,025 – 0,180) µg/l"},{"name":"o, p’ - DDD","range":"(0,025 – 0,180) µg/l"},{"name":"狄氏剂","range":"(0,008 – 0,050) µg/l"},{"name":"p, p’ - DDD","range":"(0,025 – 0,180) µg/l"},{"name":"o, p’ - DDT","range":"(0,027 – 0,190) µg/l"},{"name":"p, p’ - DDT","range":"(0,025 – 0,180) µg/l"},{"name":"bifentryna","range":"(0,025 – 0,180) µg/l"},{"name":"fenpropatryna","range":"(0,025 – 0,180) µg/l"},{"name":"λ–cyhalotryna","range":"(0,025 – 0,180) µg/l"},{"name":"fenarymol","range":"(0,025 – 0,180) µg/l"},{"name":"permetryna","range":"(0,025 – 0,180) µg/l"},{"name":"cypermetryna","range":"(0,025 – 0,180) µg/l"},{"name":"deltametryna","range":"(0,025 – 0,180) µg/l"},{"name":"Suma stężeń analizowanych pestycydów (z obliczeń)"}]},{"_id":"6a836ff8af14b9c0e7b1eded","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością","methodology":"Migracja globalna z zastosowaniem torebki, przez całkowite zanurzenie, z zastosowaniem komory pomiarowej, przez napełnienie wyrobu do płynów modelowych:","parameters":[{"name":"3% kwas octowy","range":"(1,0 – 20,0) mg/dm2"},{"name":"(6 – 120) mg/kg"},{"name":"10% etanol","range":"(1,0 – 20,0) mg/dm2"},{"name":"(6 – 120) mg/kg"},{"name":"20% etanol","range":"(1,0 – 20,0) mg/dm2"},{"name":"(6 – 120) mg/kg"},{"name":"50% etanol","range":"(1,0 – 20,0) mg/dm2"},{"name":"(6 – 120) mg/kg"},{"name":"95% etanol","range":"(1,0 – 20,0) mg/dm2"},{"name":"(6 – 120) mg/kg"},{"name":"Izooktan","range":"(1,0 – 20,0) mg/dm2"},{"name":"(6 – 120) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Migracja globalna z zastosowaniem torebki, przez całkowite zanurzenie, z zastosowaniem komory pomiarowej, przez napełnienie wyrobu do płynów modelowych:\nZakres:\n3% kwas octowy (1,0 – 20,0) mg/dm2\n(6 – 120) mg/kg\n10% etanol (1,0 – 20,0) mg/dm2\n(6 – 120) mg/kg\n20% etanol (1,0 – 20,0) mg/dm2\n(6 – 120) mg/kg\n50% etanol (1,0 – 20,0) mg/dm2\n(6 – 120) mg/kg\n95% etanol (1,0 – 20,0) mg/dm2\n(6 – 120) mg/kg\nIzooktan (1,0 – 20,0) mg/dm2\n(6 – 120) mg/kg\nMetoda wagowa","reference":"PN-EN 1186-3:2023-01","norm_bases":["PN-EN 1186-3:2023-01"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Żywności; Pracownia Badań Materiałów i Wyrobów do Kontaktu z Żywnością","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością Migracja globalna z zastosowaniem torebki, przez całkowite zanurzenie, z zastosowaniem komory pomiarowej, przez napełnienie wyrobu do płynów modelowych:\nZakres:\n3% kwas octowy (1,0 – 20,0) mg/dm2\n(6 – 120) mg/kg\n10% etanol (1,0 – 20,0) mg/dm2\n(6 – 120) mg/kg\n20% etanol (1,0 – 20,0) mg/dm2\n(6 – 120) mg/kg\n50% etanol (1,0 – 20,0) mg/dm2\n(6 – 120) mg/kg\n95% etanol (1,0 – 20,0) mg/dm2\n(6 – 120) mg/kg\nIzooktan (1,0 – 20,0) mg/dm2\n(6 – 120) mg/kg\nMetoda wagowa PN-EN 1186-3:2023-01 Materialy i wyroby z tworzyw sztucznych przeznaczone do kontaktu z zywnoscia Migracja globalna z zastosowaniem torebki, przez calkowite zanurzenie, z zastosowaniem komory pomiarowej, przez napelnienie wyrobu do plynow modelowych:\nZakres:\n3% kwas octowy (1,0 – 20,0) mg/dm2\n(6 – 120) mg/kg\n10% etanol (1,0 – 20,0) mg/dm2\n(6 – 120) mg/kg\n20% etanol (1,0 – 20,0) mg/dm2\n(6 – 120) mg/kg\n50% etanol (1,0 – 20,0) mg/dm2\n(6 – 120) mg/kg\n95% etanol (1,0 – 20,0) mg/dm2\n(6 – 120) mg/kg\nIzooktan (1,0 – 20,0) mg/dm2\n(6 – 120) mg/kg\nMetoda wagowa PN-EN 1186-3:2023-01","categories":["materials","food"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Overall migration by the pouch method, by total immersion, using a test cell, by filling the article, into food simulants:","parameters_en":[{"name":"3% acetic acid","range":"(1,0 – 20,0) mg/dm2"},{"name":"(6 – 120) mg/kg"},{"name":"10% ethanol","range":"(1,0 – 20,0) mg/dm2"},{"name":"(6 – 120) mg/kg"},{"name":"20% ethanol","range":"(1,0 – 20,0) mg/dm2"},{"name":"(6 – 120) mg/kg"},{"name":"50% ethanol","range":"(1,0 – 20,0) mg/dm2"},{"name":"(6 – 120) mg/kg"},{"name":"95% ethanol","range":"(1,0 – 20,0) mg/dm2"},{"name":"(6 – 120) mg/kg"},{"name":"Isooctane","range":"(1,0 – 20,0) mg/dm2"},{"name":"(6 – 120) mg/kg"}],"search_en":"Plastic materials and articles intended to come into contact with food Overall migration by the pouch method, by total immersion, using a test cell, by filling the article, into food simulants: Gravimetric method 3% acetic acid (6 – 120) mg/kg 10% ethanol (6 – 120) mg/kg 20% ethanol (6 – 120) mg/kg 50% ethanol (6 – 120) mg/kg 95% ethanol (6 – 120) mg/kg Isooctane (6 – 120) mg/kg PN-EN 1186-3:2023-01","technique_en":"Gravimetric method","test_object_en":"Plastic materials and articles intended to come into contact with food","search_zh":"拟与食品接触的塑料材料及制品 重量法 3% 乙酸 10% 乙醇 20% 乙醇 50% 乙醇 95% 乙醇 异辛烷 PN-EN 1186-3:2023-01","technique_zh":"重量法","test_object_zh":"拟与食品接触的塑料材料及制品","parameters_zh":[{"name":"3% 乙酸","range":"(1,0 – 20,0) mg/dm2"},{"name":"(6 – 120) mg/kg"},{"name":"10% 乙醇","range":"(1,0 – 20,0) mg/dm2"},{"name":"(6 – 120) mg/kg"},{"name":"20% 乙醇","range":"(1,0 – 20,0) mg/dm2"},{"name":"(6 – 120) mg/kg"},{"name":"50% 乙醇","range":"(1,0 – 20,0) mg/dm2"},{"name":"(6 – 120) mg/kg"},{"name":"95% 乙醇","range":"(1,0 – 20,0) mg/dm2"},{"name":"(6 – 120) mg/kg"},{"name":"异辛烷","range":"(1,0 – 20,0) mg/dm2"},{"name":"(6 – 120) mg/kg"}]},{"_id":"6a836ff8af14b9c0e7b1edee","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością","methodology":"Migracja formaldehydu do płynów modelowych","parameters":[{"name":"Zakres","range":"3% kw. octowy (1,5 – 30,0) mg/kg"},{"name":"10% etanol","range":"(1,5 – 30,0) mg/kg"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Migracja formaldehydu do płynów modelowych\nZakres:\nZakres 3% kw. octowy (1,5 – 30,0) mg/kg\n10% etanol (1,5 – 30,0) mg/kg\nMetoda spektrofotometryczna","reference":"CEN/TS 13130-23:2005","norm_bases":["CEN/TS 13130-23:2005"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Żywności; Pracownia Badań Materiałów i Wyrobów do Kontaktu z Żywnością","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością Migracja formaldehydu do płynów modelowych\nZakres:\nZakres 3% kw. octowy (1,5 – 30,0) mg/kg\n10% etanol (1,5 – 30,0) mg/kg\nMetoda spektrofotometryczna CEN/TS 13130-23:2005 Materialy i wyroby z tworzyw sztucznych przeznaczone do kontaktu z zywnoscia Migracja formaldehydu do plynow modelowych\nZakres:\nZakres 3% kw. octowy (1,5 – 30,0) mg/kg\n10% etanol (1,5 – 30,0) mg/kg\nMetoda spektrofotometryczna CEN/TS 13130-23:2005","categories":["materials","food"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Formaldehyde migration into food simulants","parameters_en":[{"name":"Range","range":"3% kw. octowy (1,5 – 30,0) mg/kg"},{"name":"10% ethanol","range":"(1,5 – 30,0) mg/kg"}],"search_en":"Plastic materials and articles intended to come into contact with food Formaldehyde migration into food simulants Spectrophotometric method Range 10% ethanol CEN/TS 13130-23:2005","technique_en":"Spectrophotometric method","test_object_en":"Plastic materials and articles intended to come into contact with food","parameters_zh":[{"name":"范围","range":"3% kw. octowy (1,5 – 30,0) mg/kg"},{"name":"10% 乙醇","range":"(1,5 – 30,0) mg/kg"}],"search_zh":"拟与食品接触的塑料材料及制品 甲醛向食品模拟物的迁移量 分光光度法 范围 10% 乙醇 CEN/TS 13130-23:2005","technique_zh":"分光光度法","test_object_zh":"拟与食品接触的塑料材料及制品","methodology_zh":"甲醛向食品模拟物的迁移量"},{"_id":"6a836ff8af14b9c0e7b1edef","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością, Wyroby z materiałów naturalnych przeznaczone do kontaktu z żywnością","methodology":"Zapach i smak przekazywane przy bezpośrednim kontakcie","parameters":[{"name":"Zakres","range":"0 – 4"}],"technique":"Metoda multiporównawcza","techniques":["Metoda multiporównawcza"],"computed":[],"activity":"Zapach i smak przekazywane przy bezpośrednim kontakcie\nZakres 0 – 4\nMetoda multiporównawcza","reference":"DIN 10955:2024-01","norm_bases":["DIN 10955:2024-01"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Żywności; Pracownia Badań Materiałów i Wyrobów do Kontaktu z Żywnością","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością, Wyroby z materiałów naturalnych przeznaczone do kontaktu z żywnością Zapach i smak przekazywane przy bezpośrednim kontakcie\nZakres 0 – 4\nMetoda multiporównawcza DIN 10955:2024-01 Materialy i wyroby z tworzyw sztucznych przeznaczone do kontaktu z zywnoscia, Wyroby z materialow naturalnych przeznaczone do kontaktu z zywnoscia Zapach i smak przekazywane przy bezposrednim kontakcie\nZakres 0 – 4\nMetoda multiporownawcza DIN 10955:2024-01","categories":["materials","food"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Odour and taste transferred on direct contact","parameters_en":[{"name":"Range","range":"0 – 4"}],"search_en":"Plastic materials and articles intended to come into contact with food, Articles made of natural materials intended to come into contact with food Odour and taste transferred on direct contact Multi-comparative method Range DIN 10955:2024-01","technique_en":"Multi-comparative method","test_object_en":"Plastic materials and articles intended to come into contact with food, Articles made of natural materials intended to come into contact with food","parameters_zh":[{"name":"范围","range":"0 – 4"}],"search_zh":"直接接触传递的气味与滋味 多重比较法 范围 DIN 10955:2024-01","methodology_zh":"直接接触传递的气味与滋味","technique_zh":"多重比较法"},{"_id":"6a836ff8af14b9c0e7b1edf0","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Wyroby ceramiczne i powierzchnie krzemianowe wyrobów innych niż ceramiczne przeznaczone do kontaktu z żywnością","methodology":"Migracja ołowiu do płynu modelowego","parameters":[{"name":"Zakres","range":"(0,1 – 10,0) mg/l"},{"name":"Zakres","range":"(0,1 – 10,0) mg/dm2"},{"name":"Zakres","range":"(0,1 – 10,0) mg/obrzeże"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Migracja ołowiu do płynu modelowego\nZakres:\nZakres (0,1 – 10,0) mg/l\nZakres (0,1 – 10,0) mg/dm2\nZakres (0,1 – 10,0) mg/obrzeże\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-EN 1388-1:2000 + Ap1:2002 | PN-EN 1388-2:2000","norm_bases":["PN-EN 1388-1:2000 + Ap1:2002","PN-EN 1388-2:2000"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Żywności; Pracownia Badań Materiałów i Wyrobów do Kontaktu z Żywnością; Pracownia Analiz Instrumentalnych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby ceramiczne i powierzchnie krzemianowe wyrobów innych niż ceramiczne przeznaczone do kontaktu z żywnością Migracja ołowiu do płynu modelowego\nZakres:\nZakres (0,1 – 10,0) mg/l\nZakres (0,1 – 10,0) mg/dm2\nZakres (0,1 – 10,0) mg/obrzeże\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN 1388-1:2000 + Ap1:2002 | PN-EN 1388-2:2000 Wyroby ceramiczne i powierzchnie krzemianowe wyrobow innych niz ceramiczne przeznaczone do kontaktu z zywnoscia Migracja olowiu do plynu modelowego\nZakres:\nZakres (0,1 – 10,0) mg/l\nZakres (0,1 – 10,0) mg/dm2\nZakres (0,1 – 10,0) mg/obrzeze\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN 1388-1:2000 + Ap1:2002 | PN-EN 1388-2:2000","categories":["food"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Migration of lead into the food simulant","parameters_en":[{"name":"Range","range":"(0,1 – 10,0) mg/l"},{"name":"Range","range":"(0,1 – 10,0) mg/dm2"},{"name":"Range","range":"(0,1 – 10,0) mg/obrzeże"}],"search_en":"Ceramic articles and silicate surfaces of non-ceramic articles intended to come into contact with food Migration of lead into the food simulant Flame atomic absorption spectrometry (FAAS) Range Range Range PN-EN 1388-1:2000 + Ap1:2002 | PN-EN 1388-2:2000","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Ceramic articles and silicate surfaces of non-ceramic articles intended to come into contact with food","parameters_zh":[{"name":"范围","range":"(0,1 – 10,0) mg/l"},{"name":"范围","range":"(0,1 – 10,0) mg/dm2"},{"name":"范围","range":"(0,1 – 10,0) mg/obrzeże"}],"search_zh":"拟与食品接触的陶瓷制品及非陶瓷制品的硅酸盐表面 火焰原子吸收光谱法（FAAS） 范围 范围 范围 PN-EN 1388-1:2000 + Ap1:2002 | PN-EN 1388-2:2000","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"拟与食品接触的陶瓷制品及非陶瓷制品的硅酸盐表面"},{"_id":"6a836ff8af14b9c0e7b1edf1","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Wyroby ceramiczne i powierzchnie krzemianowe wyrobów innych niż ceramiczne przeznaczone do kontaktu z żywnością","methodology":"Migracja kadmu do płynu modelowego","parameters":[{"name":"Zakres","range":"(0,01 – 0,50) mg/l"},{"name":"Zakres","range":"(0,01 – 0,50) mg/dm2"},{"name":"Zakres","range":"(0,01 – 0,50) mg/obrzeże"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Migracja kadmu do płynu modelowego\nZakres:\nZakres (0,01 – 0,50) mg/l\nZakres (0,01 – 0,50) mg/dm2\nZakres (0,01 – 0,50) mg/obrzeże\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-EN 1388-1:2000 + Ap1:2002 | PN-EN 1388-2:2000","norm_bases":["PN-EN 1388-1:2000 + Ap1:2002","PN-EN 1388-2:2000"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Żywności; Pracownia Badań Materiałów i Wyrobów do Kontaktu z Żywnością; Pracownia Analiz Instrumentalnych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby ceramiczne i powierzchnie krzemianowe wyrobów innych niż ceramiczne przeznaczone do kontaktu z żywnością Migracja kadmu do płynu modelowego\nZakres:\nZakres (0,01 – 0,50) mg/l\nZakres (0,01 – 0,50) mg/dm2\nZakres (0,01 – 0,50) mg/obrzeże\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN 1388-1:2000 + Ap1:2002 | PN-EN 1388-2:2000 Wyroby ceramiczne i powierzchnie krzemianowe wyrobow innych niz ceramiczne przeznaczone do kontaktu z zywnoscia Migracja kadmu do plynu modelowego\nZakres:\nZakres (0,01 – 0,50) mg/l\nZakres (0,01 – 0,50) mg/dm2\nZakres (0,01 – 0,50) mg/obrzeze\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN 1388-1:2000 + Ap1:2002 | PN-EN 1388-2:2000","categories":["food"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Cadmium migration into the simulant","parameters_en":[{"name":"Range","range":"(0,01 – 0,50) mg/l"},{"name":"Range","range":"(0,01 – 0,50) mg/dm2"},{"name":"Range","range":"(0,01 – 0,50) mg/obrzeże"}],"search_en":"Ceramic articles and silicate surfaces of non-ceramic articles intended to come into contact with food Cadmium migration into the simulant Flame atomic absorption spectrometry (FAAS) Range Range Range PN-EN 1388-1:2000 + Ap1:2002 | PN-EN 1388-2:2000","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Ceramic articles and silicate surfaces of non-ceramic articles intended to come into contact with food","parameters_zh":[{"name":"范围","range":"(0,01 – 0,50) mg/l"},{"name":"范围","range":"(0,01 – 0,50) mg/dm2"},{"name":"范围","range":"(0,01 – 0,50) mg/obrzeże"}],"search_zh":"拟与食品接触的陶瓷制品及非陶瓷制品的硅酸盐表面 火焰原子吸收光谱法（FAAS） 范围 范围 范围 PN-EN 1388-1:2000 + Ap1:2002 | PN-EN 1388-2:2000","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"拟与食品接触的陶瓷制品及非陶瓷制品的硅酸盐表面"},{"_id":"6a836ff8af14b9c0e7b1edf2","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Wyroby szklane i ceramiczne przeznaczone do kontaktu z żywnością","methodology":"Migracja metali do płynu modelowego – 4% kwas octowy","parameters":[{"name":"Ołów","range":"(0,01 – 10,0) mg/L"},{"name":"Ołów","range":"(0,01 – 10,0) mg/dm2"},{"name":"Ołów","range":"(0,01 – 10,0) mg/obrzeże"},{"name":"Kadm","range":"(0,001 – 0,50) mg/L"},{"name":"Kadm","range":"(0,001 – 0,50) mg/dm2"},{"name":"Kadm","range":"(0,001 – 0,50) mg/obrzeże"}],"technique":"Metoda spektrometrii mas z plazmą wzbudzoną indukcyjnie (ICP-MS)","techniques":["Metoda spektrometrii mas z plazmą wzbudzoną indukcyjnie (ICP-MS)"],"computed":[],"activity":"Migracja metali do płynu modelowego – 4% kwas octowy\nZakres:\nOłów (0,01 – 10,0) mg/L\nOłów (0,01 – 10,0) mg/dm2\nOłów (0,01 – 10,0) mg/obrzeże\nKadm (0,001 – 0,50) mg/L\nKadm (0,001 – 0,50) mg/dm2\nKadm (0,001 – 0,50) mg/obrzeże\nMetoda spektrometrii mas z plazmą wzbudzoną indukcyjnie (ICP-MS)","reference":"ISO 6486-1:2019","norm_bases":["ISO 6486-1:2019"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Żywności; Pracownia Badań Materiałów i Wyrobów do Kontaktu z Żywnością; Pracownia Analiz Instrumentalnych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby szklane i ceramiczne przeznaczone do kontaktu z żywnością Migracja metali do płynu modelowego – 4% kwas octowy\nZakres:\nOłów (0,01 – 10,0) mg/L\nOłów (0,01 – 10,0) mg/dm2\nOłów (0,01 – 10,0) mg/obrzeże\nKadm (0,001 – 0,50) mg/L\nKadm (0,001 – 0,50) mg/dm2\nKadm (0,001 – 0,50) mg/obrzeże\nMetoda spektrometrii mas z plazmą wzbudzoną indukcyjnie (ICP-MS) ISO 6486-1:2019 Wyroby szklane i ceramiczne przeznaczone do kontaktu z zywnoscia Migracja metali do plynu modelowego – 4% kwas octowy\nZakres:\nOlow (0,01 – 10,0) mg/L\nOlow (0,01 – 10,0) mg/dm2\nOlow (0,01 – 10,0) mg/obrzeze\nKadm (0,001 – 0,50) mg/L\nKadm (0,001 – 0,50) mg/dm2\nKadm (0,001 – 0,50) mg/obrzeze\nMetoda spektrometrii mas z plazma wzbudzona indukcyjnie (ICP-MS) ISO 6486-1:2019","categories":["materials","food"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Migration of metals into the food simulant – 4% acetic acid","parameters_en":[{"name":"Lead","range":"(0,01 – 10,0) mg/L"},{"name":"Lead","range":"(0,01 – 10,0) mg/dm2"},{"name":"Lead","range":"(0,01 – 10,0) mg/obrzeże"},{"name":"Cadmium","range":"(0,001 – 0,50) mg/L"},{"name":"Cadmium","range":"(0,001 – 0,50) mg/dm2"},{"name":"Cadmium","range":"(0,001 – 0,50) mg/obrzeże"}],"search_en":"Glass and ceramic articles intended to come into contact with food Migration of metals into the food simulant – 4% acetic acid Inductively coupled plasma mass spectrometry (ICP-MS) Lead Lead Lead Cadmium Cadmium Cadmium ISO 6486-1:2019","technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","test_object_en":"Glass and ceramic articles intended to come into contact with food","parameters_zh":[{"name":"铅","range":"(0,01 – 10,0) mg/L"},{"name":"铅","range":"(0,01 – 10,0) mg/dm2"},{"name":"铅","range":"(0,01 – 10,0) mg/obrzeże"},{"name":"镉","range":"(0,001 – 0,50) mg/L"},{"name":"镉","range":"(0,001 – 0,50) mg/dm2"},{"name":"镉","range":"(0,001 – 0,50) mg/obrzeże"}],"search_zh":"电感耦合等离子体质谱法（ICP-MS） 铅 铅 铅 镉 镉 镉 ISO 6486-1:2019","technique_zh":"电感耦合等离子体质谱法（ICP-MS）"},{"_id":"6a836ff8af14b9c0e7b1edf3","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością","methodology":"Migracja pierwszorzędowych amin aromatycznych (PAA) do płynów modelowych - 3% kw. octowy","parameters":[{"name":"2,6-toluenodiamina (2,6-TDA)","range":"(0,001 – 0,025)mg/kg"},{"name":"2,4-toluenodiamina (2,4-TDA)","range":"(0,001 – 0,025)mg/kg"},{"name":"1,5-diaminonaftalen (1,5-DAN)","range":"(0,001 – 0,025)mg/kg"},{"name":"anilina (ANL)","range":"(0,001 – 0,025)mg/kg"},{"name":"4,4’-oksydianilina (4,4’-DPE)","range":"(0,001 – 0,025)mg/kg"},{"name":"4,4’-diaminodifenylometan(4,4’-MDA)","range":"(0,001 – 0,025)mg/kg"},{"name":"3,3’-dimetylobenzydyna (3,3’-DMB)","range":"(0,001 – 0,025)mg/kg"},{"name":"1,3-fenylenodiamina (m-PDA)","range":"(0,001 – 0,025)mg/kg"},{"name":"Suma migracji PAA (z obliczeń)"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)"],"computed":[],"activity":"Migracja pierwszorzędowych amin aromatycznych (PAA) do płynów modelowych - 3% kw. octowy\nZakres:\n2,6-toluenodiamina (2,6-TDA) (0,001 – 0,025)mg/kg\n2,4-toluenodiamina (2,4-TDA) (0,001 – 0,025)mg/kg\n1,5-diaminonaftalen (1,5-DAN) (0,001 – 0,025)mg/kg\nanilina (ANL) (0,001 – 0,025)mg/kg\n4,4’-oksydianilina (4,4’-DPE) (0,001 – 0,025)mg/kg\n4,4’-diaminodifenylometan(4,4’-MDA) (0,001 – 0,025)mg/kg\n3,3’-dimetylobenzydyna (3,3’-DMB) (0,001 – 0,025)mg/kg\n1,3-fenylenodiamina (m-PDA) (0,001 – 0,025)mg/kg\nSuma migracji PAA (z obliczeń)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","reference":"PB PU,AP-02 wydanie 2 z dnia 02.01.2020 r.","norm_bases":["PB PU,AP-02 wydanie 2 z dnia 02.01.2020 r."],"lab_section":"Dział Laboratoryjny/ Oddział Badania Żywności; Pracownia Badań Materiałów i Wyrobów do Kontaktu z Żywnością; Pracownia Analiz Instrumentalnych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością Migracja pierwszorzędowych amin aromatycznych (PAA) do płynów modelowych - 3% kw. octowy\nZakres:\n2,6-toluenodiamina (2,6-TDA) (0,001 – 0,025)mg/kg\n2,4-toluenodiamina (2,4-TDA) (0,001 – 0,025)mg/kg\n1,5-diaminonaftalen (1,5-DAN) (0,001 – 0,025)mg/kg\nanilina (ANL) (0,001 – 0,025)mg/kg\n4,4’-oksydianilina (4,4’-DPE) (0,001 – 0,025)mg/kg\n4,4’-diaminodifenylometan(4,4’-MDA) (0,001 – 0,025)mg/kg\n3,3’-dimetylobenzydyna (3,3’-DMB) (0,001 – 0,025)mg/kg\n1,3-fenylenodiamina (m-PDA) (0,001 – 0,025)mg/kg\nSuma migracji PAA (z obliczeń)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV) PB PU,AP-02 wydanie 2 z dnia 02.01.2020 r. Materialy i wyroby z tworzyw sztucznych przeznaczone do kontaktu z zywnoscia Migracja pierwszorzedowych amin aromatycznych (PAA) do plynow modelowych - 3% kw. octowy\nZakres:\n2,6-toluenodiamina (2,6-TDA) (0,001 – 0,025)mg/kg\n2,4-toluenodiamina (2,4-TDA) (0,001 – 0,025)mg/kg\n1,5-diaminonaftalen (1,5-DAN) (0,001 – 0,025)mg/kg\nanilina (ANL) (0,001 – 0,025)mg/kg\n4,4’-oksydianilina (4,4’-DPE) (0,001 – 0,025)mg/kg\n4,4’-diaminodifenylometan(4,4’-MDA) (0,001 – 0,025)mg/kg\n3,3’-dimetylobenzydyna (3,3’-DMB) (0,001 – 0,025)mg/kg\n1,3-fenylenodiamina (m-PDA) (0,001 – 0,025)mg/kg\nSuma migracji PAA (z obliczen)\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC-UV) PB PU,AP-02 wydanie 2 z dnia 02.01.2020 r.","categories":["materials","food"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Migration of primary aromatic amines (PAA) into food simulants - 3% acetic acid","parameters_en":[{"name":"2,6-toluenodiamina (2,6-TDA)","range":"(0,001 – 0,025)mg/kg"},{"name":"2,4-toluenodiamina (2,4-TDA)","range":"(0,001 – 0,025)mg/kg"},{"name":"1,5-diaminonaftalen (1,5-DAN)","range":"(0,001 – 0,025)mg/kg"},{"name":"aniline (ANL)","range":"(0,001 – 0,025)mg/kg"},{"name":"4,4’-oksydianilina (4,4’-DPE)","range":"(0,001 – 0,025)mg/kg"},{"name":"4,4’-diaminodifenylometan(4,4’-MDA)","range":"(0,001 – 0,025)mg/kg"},{"name":"3,3’-dimetylobenzydyna (3,3’-DMB)","range":"(0,001 – 0,025)mg/kg"},{"name":"1,3-phenylenediamine (m-PDA)","range":"(0,001 – 0,025)mg/kg"},{"name":"Sum of PAA migration (calculated)"}],"search_en":"Plastic materials and articles intended to come into contact with food Migration of primary aromatic amines (PAA) into food simulants - 3% acetic acid High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) aniline (ANL) 1,3-phenylenediamine (m-PDA) Sum of PAA migration (calculated) PB PU,AP-02 wydanie 2 z dnia 02.01.2020 r.","technique_en":"High-performance liquid chromatography with spectrophotometric detection (HPLC-UV)","test_object_en":"Plastic materials and articles intended to come into contact with food","search_zh":"拟与食品接触的塑料材料及制品 高效液相色谱-分光光度检测法（HPLC-UV） PB PU,AP-02 wydanie 2 z dnia 02.01.2020 r.","technique_zh":"高效液相色谱-分光光度检测法（HPLC-UV）","test_object_zh":"拟与食品接触的塑料材料及制品"},{"_id":"6a836ff8af14b9c0e7b1edf4","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością","methodology":"Migracja bisfenolu A do płynów modelowych","parameters":[{"name":"Zakres","range":"3% kw. octowy (0,0030 – 0,30)mg/kg"},{"name":"20% etanol","range":"(0,0030 – 0,30)mg/kg"},{"name":"50% etanol","range":"(0,0030 – 0,30)mg/kg"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Migracja bisfenolu A do płynów modelowych\nZakres:\nZakres 3% kw. octowy (0,0030 – 0,30)mg/kg\n20% etanol (0,0030 – 0,30)mg/kg\n50% etanol (0,0030 – 0,30)mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"PB PU,AP-01 wydanie 3 z dnia 02.01.2020 r.","norm_bases":["PB PU,AP-01 wydanie 3 z dnia 02.01.2020 r."],"lab_section":"Dział Laboratoryjny/ Oddział Badania Żywności; Pracownia Badań Materiałów i Wyrobów do Kontaktu z Żywnością; Pracownia Analiz Instrumentalnych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością Migracja bisfenolu A do płynów modelowych\nZakres:\nZakres 3% kw. octowy (0,0030 – 0,30)mg/kg\n20% etanol (0,0030 – 0,30)mg/kg\n50% etanol (0,0030 – 0,30)mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) PB PU,AP-01 wydanie 3 z dnia 02.01.2020 r. Materialy i wyroby z tworzyw sztucznych przeznaczone do kontaktu z zywnoscia Migracja bisfenolu A do plynow modelowych\nZakres:\nZakres 3% kw. octowy (0,0030 – 0,30)mg/kg\n20% etanol (0,0030 – 0,30)mg/kg\n50% etanol (0,0030 – 0,30)mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) PB PU,AP-01 wydanie 3 z dnia 02.01.2020 r.","categories":["materials","food"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Migration of bisphenol A into food simulants","parameters_en":[{"name":"Range","range":"3% kw. octowy (0,0030 – 0,30)mg/kg"},{"name":"20% ethanol","range":"(0,0030 – 0,30)mg/kg"},{"name":"50% ethanol","range":"(0,0030 – 0,30)mg/kg"}],"search_en":"Plastic materials and articles intended to come into contact with food Migration of bisphenol A into food simulants High-performance liquid chromatography with fluorescence detection (HPLC-FLD) Range 20% ethanol 50% ethanol PB PU,AP-01 wydanie 3 z dnia 02.01.2020 r.","technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD)","test_object_en":"Plastic materials and articles intended to come into contact with food","parameters_zh":[{"name":"范围","range":"3% kw. octowy (0,0030 – 0,30)mg/kg"},{"name":"20% 乙醇","range":"(0,0030 – 0,30)mg/kg"},{"name":"50% 乙醇","range":"(0,0030 – 0,30)mg/kg"}],"search_zh":"拟与食品接触的塑料材料及制品 高效液相色谱-荧光检测法（HPLC-FLD） 范围 20% 乙醇 50% 乙醇 PB PU,AP-01 wydanie 3 z dnia 02.01.2020 r.","technique_zh":"高效液相色谱-荧光检测法（HPLC-FLD）","test_object_zh":"拟与食品接触的塑料材料及制品"},{"_id":"6a836ff8af14b9c0e7b1edf5","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Liczba Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Wody i Gleby; Pracownia Badań Mikrobiologicznych Wody i Gleby","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda, Woda do spozycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Escherichia coli count","search_en":"Water, Water intended for human consumption Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"水、生活饮用水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a836ff8af14b9c0e7b1edf6","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Liczba bakterii grupy coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Wody i Gleby; Pracownia Badań Mikrobiologicznych Wody i Gleby","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda, Woda do spozycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Coliform bacteria count","search_en":"Water, Water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"大肠菌群计数","search_zh":"水、生活饮用水 大肠菌群计数 膜过滤法 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a836ff8af14b9c0e7b1edf7","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w 22ºC i 36ºC","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w 22ºC i 36ºC\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Wody i Gleby; Pracownia Badań Mikrobiologicznych Wody i Gleby","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 22ºC i 36ºC\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda, Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 22ºC i 36ºC\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Water, Water intended for human consumption Plate method (pour plate) PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water, Water intended for human consumption","search_zh":"水、生活饮用水 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水、生活饮用水"},{"_id":"6a836ff8af14b9c0e7b1edf8","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Liczba enterokoków (paciorkowców kałowych)","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba enterokoków (paciorkowców kałowych)\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Wody i Gleby; Pracownia Badań Mikrobiologicznych Wody i Gleby","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Liczba enterokoków (paciorkowców kałowych)\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda, Woda do spozycia przez ludzi Liczba enterokokow (paciorkowcow kalowych)\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Enterococci (faecal streptococci) count","search_en":"Water, Water intended for human consumption Enterococci (faecal streptococci) count Membrane filtration method PN-EN ISO 7899-2:2004","technique_en":"Membrane filtration method","test_object_en":"Water, Water intended for human consumption","search_zh":"水、生活饮用水 肠球菌（粪链球菌）数 膜过滤法 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水","methodology_zh":"肠球菌（粪链球菌）数"},{"_id":"6a836ff8af14b9c0e7b1edf9","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Liczba przetrwalników beztlenowców redukujących siarczyny (Clostridia)","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba przetrwalników beztlenowców redukujących siarczyny (Clostridia)\nMetoda filtracji membranowej","reference":"PN-EN 26461-2:2001","norm_bases":["PN-EN 26461-2:2001"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Wody i Gleby; Pracownia Badań Mikrobiologicznych Wody i Gleby","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Liczba przetrwalników beztlenowców redukujących siarczyny (Clostridia)\nMetoda filtracji membranowej PN-EN 26461-2:2001 Woda, Woda do spozycia przez ludzi Liczba przetrwalnikow beztlenowcow redukujacych siarczyny (Clostridia)\nMetoda filtracji membranowej PN-EN 26461-2:2001","categories":["water"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Count of spores of sulphite-reducing anaerobes (Clostridia)","search_en":"Water, Water intended for human consumption Count of spores of sulphite-reducing anaerobes (Clostridia) Membrane filtration method PN-EN 26461-2:2001","technique_en":"Membrane filtration method","test_object_en":"Water, Water intended for human consumption","search_zh":"水、生活饮用水 亚硫酸盐还原厌氧菌（梭菌属）芽孢数 膜过滤法 PN-EN 26461-2:2001","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水","methodology_zh":"亚硫酸盐还原厌氧菌（梭菌属）芽孢数"},{"_id":"6a836ff8af14b9c0e7b1edfa","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Liczba Pseudomonas aeruginosa","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Wody i Gleby; Pracownia Badań Mikrobiologicznych Wody i Gleby","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009 Woda, Woda do spozycia przez ludzi Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Pseudomonas aeruginosa count","search_en":"Water, Water intended for human consumption Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009","technique_en":"Membrane filtration method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"铜绿假单胞菌计数","search_zh":"水、生活饮用水 铜绿假单胞菌计数 膜过滤法 PN-EN ISO 16266:2009","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a836ff8af14b9c0e7b1edfb","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Liczba gronkowców koagulazododatnich","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba gronkowców koagulazododatnich\nMetoda filtracji membranowej","reference":"PN-Z-11001-3:2000 Załącznik (normatywny) A","norm_bases":["PN-Z-11001-3:2000 Załącznik (normatywny) A"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Wody i Gleby; Pracownia Badań Mikrobiologicznych Wody i Gleby","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Liczba gronkowców koagulazododatnich\nMetoda filtracji membranowej PN-Z-11001-3:2000 Załącznik (normatywny) A Woda, Woda do spozycia przez ludzi Liczba gronkowcow koagulazododatnich\nMetoda filtracji membranowej PN-Z-11001-3:2000 Zalacznik (normatywny) A","categories":["water"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Coagulase-positive staphylococci count","search_en":"Water, Water intended for human consumption Coagulase-positive staphylococci count Membrane filtration method PN-Z-11001-3:2000 Załącznik (normatywny) A","technique_en":"Membrane filtration method","test_object_en":"Water, Water intended for human consumption","search_zh":"水、生活饮用水 凝固酶阳性葡萄球菌计数 膜过滤法 PN-Z-11001-3:2000 Załącznik (normatywny) A","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水","methodology_zh":"凝固酶阳性葡萄球菌计数"},{"_id":"6a836ff8af14b9c0e7b1edfc","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Liczba Clostridium perfringens (łącznie ze sporami)","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Clostridium perfringens (łącznie ze sporami)\nMetoda filtracji membranowej","reference":"PN-EN ISO 14189:2016-10","norm_bases":["PN-EN ISO 14189:2016-10"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Wody i Gleby; Pracownia Badań Mikrobiologicznych Wody i Gleby","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Liczba Clostridium perfringens (łącznie ze sporami)\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10 Woda, Woda do spozycia przez ludzi Liczba Clostridium perfringens (lacznie ze sporami)\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10","categories":["water"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Clostridium perfringens count (including spores)","search_en":"Water, Water intended for human consumption Clostridium perfringens count (including spores) Membrane filtration method PN-EN ISO 14189:2016-10","technique_en":"Membrane filtration method","test_object_en":"Water, Water intended for human consumption","search_zh":"水、生活饮用水 产气荚膜梭菌计数（含芽孢） 膜过滤法 PN-EN ISO 14189:2016-10","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水","methodology_zh":"产气荚膜梭菌计数（含芽孢）"},{"_id":"6a836ff8af14b9c0e7b1edfd","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Najbardziej prawdopodobna liczba bakterii grupy coli","parameters":[],"technique":"Metoda najbardziej prawdopodobniej liczby (NPL) (Test Colilert-18)","techniques":["Metoda najbardziej prawdopodobniej liczby (NPL) (Test Colilert-18)"],"computed":[],"activity":"Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda najbardziej prawdopodobniej liczby (NPL) (Test Colilert-18)","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Wody i Gleby; Pracownia Badań Mikrobiologicznych Wody i Gleby","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda najbardziej prawdopodobniej liczby (NPL) (Test Colilert-18) PN-EN ISO 9308-2:2014-06 Woda, Woda do spozycia przez ludzi Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda najbardziej prawdopodobniej liczby (NPL) (Test Colilert-18) PN-EN ISO 9308-2:2014-06","categories":["water","microbiology"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Most probable number of coliform bacteria","search_en":"Water, Water intended for human consumption Most probable number of coliform bacteria PN-EN ISO 9308-2:2014-06","test_object_en":"Water, Water intended for human consumption","methodology_zh":"大肠菌群最可能数（MPN）","search_zh":"水、生活饮用水 大肠菌群最可能数（MPN） PN-EN ISO 9308-2:2014-06","test_object_zh":"水、生活饮用水"},{"_id":"6a836ff8af14b9c0e7b1edfe","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Najbardziej prawdopodobna liczba Escherichia coli","parameters":[],"technique":"Metoda najbardziej prawdopodobniej liczby (NPL) (Test Colilert-18)","techniques":["Metoda najbardziej prawdopodobniej liczby (NPL) (Test Colilert-18)"],"computed":[],"activity":"Najbardziej prawdopodobna liczba Escherichia coli\nMetoda najbardziej prawdopodobniej liczby (NPL) (Test Colilert-18)","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Wody i Gleby; Pracownia Badań Mikrobiologicznych Wody i Gleby","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Najbardziej prawdopodobna liczba Escherichia coli\nMetoda najbardziej prawdopodobniej liczby (NPL) (Test Colilert-18) PN-EN ISO 9308-2:2014-06 Woda, Woda do spozycia przez ludzi Najbardziej prawdopodobna liczba Escherichia coli\nMetoda najbardziej prawdopodobniej liczby (NPL) (Test Colilert-18) PN-EN ISO 9308-2:2014-06","categories":["water","microbiology"],"row_index":55,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Most probable number of Escherichia coli","search_en":"Water, Water intended for human consumption Most probable number of Escherichia coli PN-EN ISO 9308-2:2014-06","test_object_en":"Water, Water intended for human consumption","search_zh":"水、生活饮用水 大肠埃希氏菌最可能数 PN-EN ISO 9308-2:2014-06","test_object_zh":"水、生活饮用水","methodology_zh":"大肠埃希氏菌最可能数"},{"_id":"6a836ff8af14b9c0e7b1edff","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Najbardziej prawdopodobna liczba enterokoków jelitowych","parameters":[],"technique":"Metoda najbardziej prawdopodobniej liczby (NPL) (Test Enterolert – DW)","techniques":["Metoda najbardziej prawdopodobniej liczby (NPL) (Test Enterolert – DW)"],"computed":[],"activity":"Najbardziej prawdopodobna liczba enterokoków jelitowych\nMetoda najbardziej prawdopodobniej liczby (NPL) (Test Enterolert – DW)","reference":"PN-EN ISO 7899-3:2025-11","norm_bases":["PN-EN ISO 7899-3:2025-11"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Wody i Gleby; Pracownia Badań Mikrobiologicznych Wody i Gleby","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Najbardziej prawdopodobna liczba enterokoków jelitowych\nMetoda najbardziej prawdopodobniej liczby (NPL) (Test Enterolert – DW) PN-EN ISO 7899-3:2025-11 Woda, Woda do spozycia przez ludzi Najbardziej prawdopodobna liczba enterokokow jelitowych\nMetoda najbardziej prawdopodobniej liczby (NPL) (Test Enterolert – DW) PN-EN ISO 7899-3:2025-11","categories":["water"],"row_index":56,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Most probable number of intestinal enterococci","search_en":"Water, Water intended for human consumption Most probable number of intestinal enterococci PN-EN ISO 7899-3:2025-11","test_object_en":"Water, Water intended for human consumption","search_zh":"水、生活饮用水 PN-EN ISO 7899-3:2025-11","test_object_zh":"水、生活饮用水"},{"_id":"6a836ff8af14b9c0e7b1ee00","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Woda","methodology":"Obecność Salmonella spp.","parameters":[],"technique":"Metoda filtracji membranowej z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda filtracji membranowej z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność Salmonella spp.\nMetoda filtracji membranowej z potwierdzeniem biochemicznym i serologicznym","reference":"PN-EN ISO 19250:2013-07","norm_bases":["PN-EN ISO 19250:2013-07"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Wody i Gleby; Pracownia Badań Mikrobiologicznych Wody i Gleby","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Obecność Salmonella spp.\nMetoda filtracji membranowej z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 19250:2013-07 Woda Obecnosc Salmonella spp.\nMetoda filtracji membranowej z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 19250:2013-07","categories":["microbiology","water"],"row_index":57,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of Salmonella spp.","search_en":"Water Presence of Salmonella spp. Membrane filtration method with biochemical and serological confirmation PN-EN ISO 19250:2013-07","technique_en":"Membrane filtration method with biochemical and serological confirmation","test_object_en":"Water","methodology_zh":"沙门氏菌属（Salmonella spp.）的检出","search_zh":"水 沙门氏菌属（Salmonella spp.）的检出 PN-EN ISO 19250:2013-07","test_object_zh":"水"},{"_id":"6a836ff8af14b9c0e7b1ee01","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Woda","methodology":"Liczba Legionella sp.","parameters":[{"name":"Matryca A: Procedura 5 (podłoże A – BCYE) Procedura 7 (podłoże C – GVPC) Procedura 1 (podłoże A – BCYE)"}],"technique":"Metoda filtracji membranowej; Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda filtracji membranowej","Metoda płytkowa (posiew powierzchniowy)"],"computed":[],"activity":"Liczba Legionella sp.\nMatryca A: Procedura 5 (podłoże A – BCYE) Procedura 7 (podłoże C – GVPC) Procedura 1 (podłoże A – BCYE)\nMetoda filtracji membranowej; Metoda płytkowa (posiew powierzchniowy)","reference":"PN-EN ISO 11731:2017-08 +Ap1:2019-12","norm_bases":["PN-EN ISO 11731:2017-08 +Ap1:2019-12"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Wody i Gleby; Pracownia Badań Mikrobiologicznych Wody i Gleby","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Liczba Legionella sp.\nMatryca A: Procedura 5 (podłoże A – BCYE) Procedura 7 (podłoże C – GVPC) Procedura 1 (podłoże A – BCYE)\nMetoda filtracji membranowej; Metoda płytkowa (posiew powierzchniowy) PN-EN ISO 11731:2017-08 +Ap1:2019-12 Woda Liczba Legionella sp.\nMatryca A: Procedura 5 (podloze A – BCYE) Procedura 7 (podloze C – GVPC) Procedura 1 (podloze A – BCYE)\nMetoda filtracji membranowej; Metoda plytkowa (posiew powierzchniowy) PN-EN ISO 11731:2017-08 +Ap1:2019-12","categories":["microbiology","water"],"row_index":58,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Legionella sp. count","search_en":"Water Legionella sp. count Membrane filtration method; Plate method (spread plate) PN-EN ISO 11731:2017-08 +Ap1:2019-12","technique_en":"Membrane filtration method; Plate method (spread plate)","test_object_en":"Water","search_zh":"水 军团菌属计数 PN-EN ISO 11731:2017-08 +Ap1:2019-12","test_object_zh":"水","methodology_zh":"军团菌属计数"},{"_id":"6a836ff8af14b9c0e7b1ee02","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Woda","methodology":"Liczba Legionella sp.","parameters":[{"name":"Matryca B: Procedura 7 (podłoże C – GVPC)"}],"technique":"Metoda filtracji membranowej; Metoda płytkowa (posiew powierzchniowy) procedura 1, 2, 3 (podłoże C – GVPC)","techniques":["Metoda filtracji membranowej","Metoda płytkowa (posiew powierzchniowy) procedura 1, 2, 3 (podłoże C – GVPC)"],"computed":[],"activity":"Liczba Legionella sp.\nMatryca B: Procedura 7 (podłoże C – GVPC)\nMetoda filtracji membranowej; Metoda płytkowa (posiew powierzchniowy) procedura 1, 2, 3 (podłoże C – GVPC)","reference":"PN-EN ISO 11731:2017-08 +Ap1:2019-12","norm_bases":["PN-EN ISO 11731:2017-08 +Ap1:2019-12"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Wody i Gleby; Pracownia Badań Mikrobiologicznych Wody i Gleby","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Liczba Legionella sp.\nMatryca B: Procedura 7 (podłoże C – GVPC)\nMetoda filtracji membranowej; Metoda płytkowa (posiew powierzchniowy) procedura 1, 2, 3 (podłoże C – GVPC) PN-EN ISO 11731:2017-08 +Ap1:2019-12 Woda Liczba Legionella sp.\nMatryca B: Procedura 7 (podloze C – GVPC)\nMetoda filtracji membranowej; Metoda plytkowa (posiew powierzchniowy) procedura 1, 2, 3 (podloze C – GVPC) PN-EN ISO 11731:2017-08 +Ap1:2019-12","categories":["microbiology","water"],"row_index":59,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Legionella sp. count","parameters_en":[{"name":"Matrix B: Procedure 7 (medium C – GVPC)"}],"search_en":"Water Legionella sp. count Membrane filtration method; Plate method (surface plating) procedure 1, 2, 3 (medium C – GVPC) Matrix B: Procedure 7 (medium C – GVPC) PN-EN ISO 11731:2017-08 +Ap1:2019-12","technique_en":"Membrane filtration method; Plate method (surface plating) procedure 1, 2, 3 (medium C – GVPC)","test_object_en":"Water","search_zh":"水 军团菌属计数 PN-EN ISO 11731:2017-08 +Ap1:2019-12","test_object_zh":"水","methodology_zh":"军团菌属计数"},{"_id":"6a836ff8af14b9c0e7b1ee03","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Woda","methodology":"Najbardziej prawdopodobna liczba Pseudomonas aeruginosa","parameters":[],"technique":"Metoda najbardziej prawdopodobniej liczby (NPL) (Test Pseudalert)","techniques":["Metoda najbardziej prawdopodobniej liczby (NPL) (Test Pseudalert)"],"computed":[],"activity":"Najbardziej prawdopodobna liczba Pseudomonas aeruginosa\nMetoda najbardziej prawdopodobniej liczby (NPL) (Test Pseudalert)","reference":"PN-EN ISO 16266-2:2022-04","norm_bases":["PN-EN ISO 16266-2:2022-04"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Wody i Gleby; Pracownia Badań Mikrobiologicznych Wody i Gleby","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Najbardziej prawdopodobna liczba Pseudomonas aeruginosa\nMetoda najbardziej prawdopodobniej liczby (NPL) (Test Pseudalert) PN-EN ISO 16266-2:2022-04 Woda Najbardziej prawdopodobna liczba Pseudomonas aeruginosa\nMetoda najbardziej prawdopodobniej liczby (NPL) (Test Pseudalert) PN-EN ISO 16266-2:2022-04","categories":["water"],"row_index":60,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Most probable number of Pseudomonas aeruginosa","search_en":"Water Most probable number of Pseudomonas aeruginosa PN-EN ISO 16266-2:2022-04","test_object_en":"Water","search_zh":"水 PN-EN ISO 16266-2:2022-04","test_object_zh":"水"},{"_id":"6a836ff8af14b9c0e7b1ee04","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Woda","methodology":"Najbardziej prawdopodobna liczba Escherichia coli","parameters":[],"technique":"Metoda najbardziej prawdopodobniej liczby (NPL) (zminiaturyzowana)","techniques":["Metoda najbardziej prawdopodobniej liczby (NPL) (zminiaturyzowana)"],"computed":[],"activity":"Najbardziej prawdopodobna liczba Escherichia coli\nMetoda najbardziej prawdopodobniej liczby (NPL) (zminiaturyzowana)","reference":"PN-EN ISO 9308-3:2002","norm_bases":["PN-EN ISO 9308-3:2002"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Wody i Gleby; Pracownia Badań Mikrobiologicznych Wody i Gleby","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Najbardziej prawdopodobna liczba Escherichia coli\nMetoda najbardziej prawdopodobniej liczby (NPL) (zminiaturyzowana) PN-EN ISO 9308-3:2002 Woda Najbardziej prawdopodobna liczba Escherichia coli\nMetoda najbardziej prawdopodobniej liczby (NPL) (zminiaturyzowana) PN-EN ISO 9308-3:2002","categories":["water","microbiology"],"row_index":61,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Most probable number of Escherichia coli","search_en":"Water Most probable number of Escherichia coli Most probable number method (MPN) (miniaturized) PN-EN ISO 9308-3:2002","technique_en":"Most probable number method (MPN) (miniaturized)","test_object_en":"Water","search_zh":"水 大肠埃希氏菌最可能数 PN-EN ISO 9308-3:2002","test_object_zh":"水","methodology_zh":"大肠埃希氏菌最可能数"},{"_id":"6a836ff8af14b9c0e7b1ee05","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Woda","methodology":"Ogólna liczba mikroorganizmów w (30±1)ºC","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w (30±1)ºC\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Wody i Gleby; Pracownia Badań Mikrobiologicznych Wody i Gleby","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Ogólna liczba mikroorganizmów w (30±1)ºC\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda Ogolna liczba mikroorganizmow w (30±1)ºC\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":62,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Water Plate method (pour plate) PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water","search_zh":"水 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水"},{"_id":"6a836ff8af14b9c0e7b1ee06","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Gleba, piasek, kompost","methodology":"Liczba żywych jaj pasożytów jelitowych","parameters":[{"name":"Ascaris spp., Trichuris spp., Toxocara spp."},{"name":"Zakres","range":"od 1 szt./100 g"},{"name":"od 10 szt./kg g s.m."}],"technique":"Metoda mikroskopowa","techniques":["Metoda mikroskopowa"],"computed":[],"activity":"Liczba żywych jaj pasożytów jelitowych\nZakres:\nAscaris spp., Trichuris spp., Toxocara spp.\nZakres od 1 szt./100 g\nod 10 szt./kg g s.m.\nMetoda mikroskopowa","reference":"PB MW-08 wydanie 5 z dnia 30.08.2024 r. w oparciu o normę | PN-Z-19006:2023-04","norm_bases":["PB MW-08 wydanie 5 z dnia 30.08.2024 r. w oparciu o normę","PN-Z-19006:2023-04"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Wody i Gleby; Pracownia Badań Mikrobiologicznych Wody i Gleby","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, piasek, kompost Liczba żywych jaj pasożytów jelitowych\nZakres:\nAscaris spp., Trichuris spp., Toxocara spp.\nZakres od 1 szt./100 g\nod 10 szt./kg g s.m.\nMetoda mikroskopowa PB MW-08 wydanie 5 z dnia 30.08.2024 r. w oparciu o normę | PN-Z-19006:2023-04 Gleba, piasek, kompost Liczba zywych jaj pasozytow jelitowych\nZakres:\nAscaris spp., Trichuris spp., Toxocara spp.\nZakres od 1 szt./100 g\nod 10 szt./kg g s.m.\nMetoda mikroskopowa PB MW-08 wydanie 5 z dnia 30.08.2024 r. w oparciu o norme | PN-Z-19006:2023-04","categories":["environment"],"row_index":63,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Ascaris spp., Trichuris spp., Toxocara spp."},{"name":"Range","range":"od 1 szt./100 g"},{"name":"from 10 pcs./kg g d.m."}],"search_en":"Microscopic method Range from 10 pcs./kg g d.m. PB MW-08 wydanie 5 z dnia 30.08.2024 r. w oparciu o normę | PN-Z-19006:2023-04","technique_en":"Microscopic method","parameters_zh":[{"name":"Ascaris spp., Trichuris spp., Toxocara spp."},{"name":"范围","range":"od 1 szt./100 g"},{"name":"od 10 szt./kg g s.m."}],"search_zh":"显微镜法 范围 PB MW-08 wydanie 5 z dnia 30.08.2024 r. w oparciu o normę | PN-Z-19006:2023-04","technique_zh":"显微镜法"},{"_id":"6a836ff8af14b9c0e7b1ee07","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Próbki środowiskowe z powierzchni technicznych - wymaz z powierzchni ograniczonej szablonem - wymaz z powierzchni nieograniczonej szablonem","methodology":"Liczba pleśni i drożdży","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba pleśni i drożdży\nMetoda płytkowa (posiew wgłębny)","reference":"PN-ISO 7954:1999","norm_bases":["PN-ISO 7954:1999"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Wody i Gleby; Pracownia Badań Mikrobiologicznych Wody i Gleby","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Próbki środowiskowe z powierzchni technicznych - wymaz z powierzchni ograniczonej szablonem - wymaz z powierzchni nieograniczonej szablonem Liczba pleśni i drożdży\nMetoda płytkowa (posiew wgłębny) PN-ISO 7954:1999 Probki srodowiskowe z powierzchni technicznych - wymaz z powierzchni ograniczonej szablonem - wymaz z powierzchni nieograniczonej szablonem Liczba plesni i drozdzy\nMetoda plytkowa (posiew wglebny) PN-ISO 7954:1999","categories":["environment"],"row_index":64,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mould and yeast count","search_en":"Environmental samples from technical surfaces - swab from a template-delimited surface - swab from a surface not delimited by a template Mould and yeast count Plate method (pour plate) PN-ISO 7954:1999","technique_en":"Plate method (pour plate)","test_object_en":"Environmental samples from technical surfaces - swab from a template-delimited surface - swab from a surface not delimited by a template","search_zh":"霉菌与酵母菌计数 平板法（倾注培养） PN-ISO 7954:1999","technique_zh":"平板法（倾注培养）","methodology_zh":"霉菌与酵母菌计数"},{"_id":"6a836ff8af14b9c0e7b1ee08","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Próbki środowiskowe z powierzchni technicznych - wymaz z powierzchni ograniczonej szablonem - wymaz z powierzchni nieograniczonej szablonem","methodology":"Obecność Legionella sp.","parameters":[{"name":"Matryca B Procedura 7 (podłoże C – GVPC)"}],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Obecność Legionella sp.\nMatryca B Procedura 7 (podłoże C – GVPC)\nMetoda filtracji membranowej","reference":"PN-EN ISO 11731:2017-08 +Ap1:2019-12","norm_bases":["PN-EN ISO 11731:2017-08 +Ap1:2019-12"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Wody i Gleby; Pracownia Badań Mikrobiologicznych Wody i Gleby","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Próbki środowiskowe z powierzchni technicznych - wymaz z powierzchni ograniczonej szablonem - wymaz z powierzchni nieograniczonej szablonem Obecność Legionella sp.\nMatryca B Procedura 7 (podłoże C – GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 +Ap1:2019-12 Probki srodowiskowe z powierzchni technicznych - wymaz z powierzchni ograniczonej szablonem - wymaz z powierzchni nieograniczonej szablonem Obecnosc Legionella sp.\nMatryca B Procedura 7 (podloze C – GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 +Ap1:2019-12","categories":["microbiology","environment"],"row_index":65,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of Legionella sp.","parameters_en":[{"name":"Matrix B Procedure 7 (medium C – GVPC)"}],"search_en":"Environmental samples from technical surfaces - swab from a template-delimited surface - swab from a surface not delimited by a template Presence of Legionella sp. Membrane filtration method Matrix B Procedure 7 (medium C – GVPC) PN-EN ISO 11731:2017-08 +Ap1:2019-12","technique_en":"Membrane filtration method","test_object_en":"Environmental samples from technical surfaces - swab from a template-delimited surface - swab from a surface not delimited by a template","search_zh":"膜过滤法 PN-EN ISO 11731:2017-08 +Ap1:2019-12","technique_zh":"膜过滤法"},{"_id":"6a836ff8af14b9c0e7b1ee09","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Mleko w proszku i produkty w proszku dla niemowląt","methodology":"Obecność Enterobacteriaceae","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność Enterobacteriaceae\nMetoda hodowlana z potwierdzeniem biochemicznym","reference":"PN–EN ISO 21528-1:2017-08","norm_bases":["PN–EN ISO 21528-1:2017-08"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Żywności; Pracownia Badań Mikrobiologicznych Żywności","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mleko w proszku i produkty w proszku dla niemowląt Obecność Enterobacteriaceae\nMetoda hodowlana z potwierdzeniem biochemicznym PN–EN ISO 21528-1:2017-08 Mleko w proszku i produkty w proszku dla niemowlat Obecnosc Enterobacteriaceae\nMetoda hodowlana z potwierdzeniem biochemicznym PN–EN ISO 21528-1:2017-08","categories":["food"],"row_index":66,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of Enterobacteriaceae","search_en":"Milk powder and powdered products for infants Presence of Enterobacteriaceae Culture method with biochemical confirmation PN–EN ISO 21528-1:2017-08","technique_en":"Culture method with biochemical confirmation","test_object_en":"Milk powder and powdered products for infants","search_zh":"肠杆菌科的检出 培养法结合生化确认 PN–EN ISO 21528-1:2017-08","technique_zh":"培养法结合生化确认","methodology_zh":"肠杆菌科的检出"},{"_id":"6a836ff8af14b9c0e7b1ee0a","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Mleko w proszku i produkty w proszku dla niemowląt","methodology":"Obecność Cronobacter spp.","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność Cronobacter spp.\nMetoda hodowlana z potwierdzeniem biochemicznym","reference":"PN-EN ISO 22964:2017-06","norm_bases":["PN-EN ISO 22964:2017-06"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Żywności; Pracownia Badań Mikrobiologicznych Żywności","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mleko w proszku i produkty w proszku dla niemowląt Obecność Cronobacter spp.\nMetoda hodowlana z potwierdzeniem biochemicznym PN-EN ISO 22964:2017-06 Mleko w proszku i produkty w proszku dla niemowlat Obecnosc Cronobacter spp.\nMetoda hodowlana z potwierdzeniem biochemicznym PN-EN ISO 22964:2017-06","categories":["food"],"row_index":67,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of Cronobacter spp.","search_en":"Milk powder and powdered products for infants Presence of Cronobacter spp. Culture method with biochemical confirmation PN-EN ISO 22964:2017-06","technique_en":"Culture method with biochemical confirmation","test_object_en":"Milk powder and powdered products for infants","search_zh":"克罗诺杆菌属（Cronobacter spp.）的检出 培养法结合生化确认 PN-EN ISO 22964:2017-06","technique_zh":"培养法结合生化确认","methodology_zh":"克罗诺杆菌属（Cronobacter spp.）的检出"},{"_id":"6a836ff8af14b9c0e7b1ee0b","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Mleko i produkty mleczne – sery wyprodukowane z mleka surowego","methodology":"Liczba gronkowców koagulazo-dodatnich (Staphylococcus aureus i innych gatunków)","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba gronkowców koagulazo-dodatnich (Staphylococcus aureus i innych gatunków)\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6888-2:2022-03 +A1:2024-02","norm_bases":["PN-EN ISO 6888-2:2022-03 +A1:2024-02"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Żywności; Pracownia Badań Mikrobiologicznych Żywności","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mleko i produkty mleczne – sery wyprodukowane z mleka surowego Liczba gronkowców koagulazo-dodatnich (Staphylococcus aureus i innych gatunków)\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6888-2:2022-03 +A1:2024-02 Mleko i produkty mleczne – sery wyprodukowane z mleka surowego Liczba gronkowcow koagulazo-dodatnich (Staphylococcus aureus i innych gatunkow)\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6888-2:2022-03 +A1:2024-02","categories":["food"],"row_index":68,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Coagulase-positive staphylococci count (Staphylococcus aureus and other species)","search_en":"Milk and dairy products – cheeses made from raw milk Coagulase-positive staphylococci count (Staphylococcus aureus and other species) Plate method (pour plate) PN-EN ISO 6888-2:2022-03 +A1:2024-02","technique_en":"Plate method (pour plate)","test_object_en":"Milk and dairy products – cheeses made from raw milk","search_zh":"凝固酶阳性葡萄球菌数（金黄色葡萄球菌及其他菌种） 平板法（倾注培养） PN-EN ISO 6888-2:2022-03 +A1:2024-02","technique_zh":"平板法（倾注培养）","methodology_zh":"凝固酶阳性葡萄球菌数（金黄色葡萄球菌及其他菌种）"},{"_id":"6a836ff8af14b9c0e7b1ee0c","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Przetwory owocowe, warzywne i warzywno-mięsne − konserwy","methodology":"Szczelność opakowań hermetycznie zamkniętych","parameters":[],"technique":"Metoda próżniowa","techniques":["Metoda próżniowa"],"computed":[],"activity":"Szczelność opakowań hermetycznie zamkniętych\nMetoda próżniowa","reference":"PN-90/A-75052.02 z wyłączeniem p. 2.2.4","norm_bases":["PN-90/A-75052.02 z wyłączeniem p. 2.2.4"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Żywności; Pracownia Badań Mikrobiologicznych Żywności","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przetwory owocowe, warzywne i warzywno-mięsne − konserwy Szczelność opakowań hermetycznie zamkniętych\nMetoda próżniowa PN-90/A-75052.02 z wyłączeniem p. 2.2.4 Przetwory owocowe, warzywne i warzywno-miesne − konserwy Szczelnosc opakowan hermetycznie zamknietych\nMetoda prozniowa PN-90/A-75052.02 z wylaczeniem p. 2.2.4","categories":["other"],"row_index":69,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Leak tightness of hermetically sealed packaging","search_en":"Fruit, vegetable and vegetable-meat products − canned goods Leak tightness of hermetically sealed packaging Vacuum method PN-90/A-75052.02 z wyłączeniem p. 2.2.4","technique_en":"Vacuum method","test_object_en":"Fruit, vegetable and vegetable-meat products − canned goods","search_zh":"密闭包装的密封性 真空法 PN-90/A-75052.02 z wyłączeniem p. 2.2.4","technique_zh":"真空法","methodology_zh":"密闭包装的密封性"},{"_id":"6a836ff8af14b9c0e7b1ee0d","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Przetwory owocowe, warzywne i warzywno-mięsne − konserwy","methodology":"Trwałość konserw","parameters":[],"technique":"Metoda próby termostatowej","techniques":["Metoda próby termostatowej"],"computed":[],"activity":"Trwałość konserw\nMetoda próby termostatowej","reference":"PN-90/A-75052.03","norm_bases":["PN-90/A-75052.03"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Żywności; Pracownia Badań Mikrobiologicznych Żywności","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przetwory owocowe, warzywne i warzywno-mięsne − konserwy Trwałość konserw\nMetoda próby termostatowej PN-90/A-75052.03 Przetwory owocowe, warzywne i warzywno-miesne − konserwy Trwalosc konserw\nMetoda proby termostatowej PN-90/A-75052.03","categories":["other"],"row_index":70,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Shelf stability of canned products","search_en":"Fruit, vegetable and vegetable-meat products − canned goods Shelf stability of canned products Thermostatic test method PN-90/A-75052.03","technique_en":"Thermostatic test method","test_object_en":"Fruit, vegetable and vegetable-meat products − canned goods","methodology_zh":"罐头保存性","search_zh":"罐头保存性 恒温试验法 PN-90/A-75052.03","technique_zh":"恒温试验法"},{"_id":"6a836ff8af14b9c0e7b1ee0e","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Mięso i przetwory mięsne − konserwy","methodology":"Szczelność opakowań hermetycznie zamkniętych","parameters":[],"technique":"Metoda próżniowa","techniques":["Metoda próżniowa"],"computed":[],"activity":"Szczelność opakowań hermetycznie zamkniętych\nMetoda próżniowa","reference":"PN-A-82055-4:1997+Az1:2002 z wyłączeniem p. 2.4.2 i 2.4.3","norm_bases":["PN-A-82055-4:1997+Az1:2002 z wyłączeniem p. 2.4.2 i 2.4.3"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Żywności; Pracownia Badań Mikrobiologicznych Żywności","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i przetwory mięsne − konserwy Szczelność opakowań hermetycznie zamkniętych\nMetoda próżniowa PN-A-82055-4:1997+Az1:2002 z wyłączeniem p. 2.4.2 i 2.4.3 Mieso i przetwory miesne − konserwy Szczelnosc opakowan hermetycznie zamknietych\nMetoda prozniowa PN-A-82055-4:1997+Az1:2002 z wylaczeniem p. 2.4.2 i 2.4.3","categories":["food"],"row_index":71,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Leak tightness of hermetically sealed packaging","search_en":"Meat and meat products − canned products Leak tightness of hermetically sealed packaging Vacuum method PN-A-82055-4:1997+Az1:2002 z wyłączeniem p. 2.4.2 i 2.4.3","technique_en":"Vacuum method","test_object_en":"Meat and meat products − canned products","search_zh":"密闭包装的密封性 真空法 PN-A-82055-4:1997+Az1:2002 z wyłączeniem p. 2.4.2 i 2.4.3","technique_zh":"真空法","methodology_zh":"密闭包装的密封性"},{"_id":"6a836ff8af14b9c0e7b1ee0f","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Mięso i przetwory mięsne − konserwy","methodology":"Trwałość konserw","parameters":[],"technique":"Metoda próby termostatowej","techniques":["Metoda próby termostatowej"],"computed":[],"activity":"Trwałość konserw\nMetoda próby termostatowej","reference":"PN-A-82055-5:1994 z wyłączeniem p. 2.5.2","norm_bases":["PN-A-82055-5:1994 z wyłączeniem p. 2.5.2"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Żywności; Pracownia Badań Mikrobiologicznych Żywności","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i przetwory mięsne − konserwy Trwałość konserw\nMetoda próby termostatowej PN-A-82055-5:1994 z wyłączeniem p. 2.5.2 Mieso i przetwory miesne − konserwy Trwalosc konserw\nMetoda proby termostatowej PN-A-82055-5:1994 z wylaczeniem p. 2.5.2","categories":["food"],"row_index":72,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Shelf stability of canned products","search_en":"Meat and meat products − canned products Shelf stability of canned products Thermostatic test method PN-A-82055-5:1994 z wyłączeniem p. 2.5.2","technique_en":"Thermostatic test method","test_object_en":"Meat and meat products − canned products","methodology_zh":"罐头保存性","search_zh":"罐头保存性 恒温试验法 PN-A-82055-5:1994 z wyłączeniem p. 2.5.2","technique_zh":"恒温试验法"},{"_id":"6a836ff8af14b9c0e7b1ee10","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Konserwy rybne","methodology":"Szczelność opakowań hermetycznie zamkniętych","parameters":[],"technique":"Metoda próżniowa","techniques":["Metoda próżniowa"],"computed":[],"activity":"Szczelność opakowań hermetycznie zamkniętych\nMetoda próżniowa","reference":"PN-92/A-86732","norm_bases":["PN-92/A-86732"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Żywności; Pracownia Badań Mikrobiologicznych Żywności","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Konserwy rybne Szczelność opakowań hermetycznie zamkniętych\nMetoda próżniowa PN-92/A-86732 Konserwy rybne Szczelnosc opakowan hermetycznie zamknietych\nMetoda prozniowa PN-92/A-86732","categories":["other"],"row_index":73,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Leak tightness of hermetically sealed packaging","search_en":"Canned fish Leak tightness of hermetically sealed packaging Vacuum method PN-92/A-86732","technique_en":"Vacuum method","test_object_en":"Canned fish","search_zh":"鱼罐头 密闭包装的密封性 真空法 PN-92/A-86732","technique_zh":"真空法","test_object_zh":"鱼罐头","methodology_zh":"密闭包装的密封性"},{"_id":"6a836ff8af14b9c0e7b1ee11","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Konserwy rybne","methodology":"Trwałość konserw","parameters":[],"technique":"Metoda próby termostatowej","techniques":["Metoda próby termostatowej"],"computed":[],"activity":"Trwałość konserw\nMetoda próby termostatowej","reference":"PN-92/A-86732","norm_bases":["PN-92/A-86732"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Żywności; Pracownia Badań Mikrobiologicznych Żywności","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Konserwy rybne Trwałość konserw\nMetoda próby termostatowej PN-92/A-86732 Konserwy rybne Trwalosc konserw\nMetoda proby termostatowej PN-92/A-86732","categories":["other"],"row_index":74,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Shelf stability of canned products","search_en":"Canned fish Shelf stability of canned products Thermostatic test method PN-92/A-86732","technique_en":"Thermostatic test method","test_object_en":"Canned fish","methodology_zh":"罐头保存性","search_zh":"鱼罐头 罐头保存性 恒温试验法 PN-92/A-86732","technique_zh":"恒温试验法","test_object_zh":"鱼罐头"},{"_id":"6a836ff8af14b9c0e7b1ee12","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Kosmetyki","methodology":"Obecność Staphylococcus aureus","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność Staphylococcus aureus\nMetoda hodowlana z potwierdzeniem biochemicznym","reference":"PN-EN ISO 22718:2016-01 +A1:2023-01","norm_bases":["PN-EN ISO 22718:2016-01 +A1:2023-01"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Żywności; Pracownia Badań Mikrobiologicznych Żywności","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kosmetyki Obecność Staphylococcus aureus\nMetoda hodowlana z potwierdzeniem biochemicznym PN-EN ISO 22718:2016-01 +A1:2023-01 Kosmetyki Obecnosc Staphylococcus aureus\nMetoda hodowlana z potwierdzeniem biochemicznym PN-EN ISO 22718:2016-01 +A1:2023-01","categories":["pharma"],"row_index":75,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of Staphylococcus aureus","search_en":"Cosmetics Presence of Staphylococcus aureus Culture method with biochemical confirmation PN-EN ISO 22718:2016-01 +A1:2023-01","technique_en":"Culture method with biochemical confirmation","test_object_en":"Cosmetics","methodology_zh":"金黄色葡萄球菌（Staphylococcus aureus）检出","search_zh":"化妆品 金黄色葡萄球菌（Staphylococcus aureus）检出 培养法结合生化确认 PN-EN ISO 22718:2016-01 +A1:2023-01","technique_zh":"培养法结合生化确认","test_object_zh":"化妆品"},{"_id":"6a836ff8af14b9c0e7b1ee13","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Kosmetyki","methodology":"Obecność Escherichia coli","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność Escherichia coli\nMetoda hodowlana z potwierdzeniem biochemicznym","reference":"PN-EN ISO 21150:2016-01 +A1:2023-03","norm_bases":["PN-EN ISO 21150:2016-01 +A1:2023-03"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Żywności; Pracownia Badań Mikrobiologicznych Żywności","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kosmetyki Obecność Escherichia coli\nMetoda hodowlana z potwierdzeniem biochemicznym PN-EN ISO 21150:2016-01 +A1:2023-03 Kosmetyki Obecnosc Escherichia coli\nMetoda hodowlana z potwierdzeniem biochemicznym PN-EN ISO 21150:2016-01 +A1:2023-03","categories":["microbiology","pharma"],"row_index":76,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of Escherichia coli","search_en":"Cosmetics Presence of Escherichia coli Culture method with biochemical confirmation PN-EN ISO 21150:2016-01 +A1:2023-03","technique_en":"Culture method with biochemical confirmation","test_object_en":"Cosmetics","methodology_zh":"大肠埃希氏菌（Escherichia coli）检出","search_zh":"化妆品 大肠埃希氏菌（Escherichia coli）检出 培养法结合生化确认 PN-EN ISO 21150:2016-01 +A1:2023-03","technique_zh":"培养法结合生化确认","test_object_zh":"化妆品"},{"_id":"6a836ff8af14b9c0e7b1ee14","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Kosmetyki","methodology":"Obecność Pseudomonas aeruginosa","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność Pseudomonas aeruginosa\nMetoda hodowlana z potwierdzeniem biochemicznym","reference":"PN-EN ISO 22717:2016-01 +A1:2023-03","norm_bases":["PN-EN ISO 22717:2016-01 +A1:2023-03"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Żywności; Pracownia Badań Mikrobiologicznych Żywności","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kosmetyki Obecność Pseudomonas aeruginosa\nMetoda hodowlana z potwierdzeniem biochemicznym PN-EN ISO 22717:2016-01 +A1:2023-03 Kosmetyki Obecnosc Pseudomonas aeruginosa\nMetoda hodowlana z potwierdzeniem biochemicznym PN-EN ISO 22717:2016-01 +A1:2023-03","categories":["pharma"],"row_index":77,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of Pseudomonas aeruginosa","search_en":"Cosmetics Presence of Pseudomonas aeruginosa Culture method with biochemical confirmation PN-EN ISO 22717:2016-01 +A1:2023-03","technique_en":"Culture method with biochemical confirmation","test_object_en":"Cosmetics","methodology_zh":"铜绿假单胞菌（Pseudomonas aeruginosa）检出","search_zh":"化妆品 铜绿假单胞菌（Pseudomonas aeruginosa）检出 培养法结合生化确认 PN-EN ISO 22717:2016-01 +A1:2023-03","technique_zh":"培养法结合生化确认","test_object_zh":"化妆品"},{"_id":"6a836ff8af14b9c0e7b1ee15","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Kosmetyki","methodology":"Obecność Candida albicans","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność Candida albicans\nMetoda hodowlana z potwierdzeniem biochemicznym","reference":"PN-EN ISO 18416:2016-01 +A1:2023-03","norm_bases":["PN-EN ISO 18416:2016-01 +A1:2023-03"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Żywności; Pracownia Badań Mikrobiologicznych Żywności","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kosmetyki Obecność Candida albicans\nMetoda hodowlana z potwierdzeniem biochemicznym PN-EN ISO 18416:2016-01 +A1:2023-03 Kosmetyki Obecnosc Candida albicans\nMetoda hodowlana z potwierdzeniem biochemicznym PN-EN ISO 18416:2016-01 +A1:2023-03","categories":["pharma"],"row_index":78,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of Candida albicans","search_en":"Cosmetics Presence of Candida albicans Culture method with biochemical confirmation PN-EN ISO 18416:2016-01 +A1:2023-03","technique_en":"Culture method with biochemical confirmation","test_object_en":"Cosmetics","methodology_zh":"白色念珠菌（Candida albicans）检出","search_zh":"化妆品 白色念珠菌（Candida albicans）检出 培养法结合生化确认 PN-EN ISO 18416:2016-01 +A1:2023-03","technique_zh":"培养法结合生化确认","test_object_zh":"化妆品"},{"_id":"6a836ff8af14b9c0e7b1ee16","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Kosmetyki","methodology":"Liczba bakterii tlenowych mezofilnych","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba bakterii tlenowych mezofilnych\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 21149:2017-07 +A1:2023-01","norm_bases":["PN-EN ISO 21149:2017-07 +A1:2023-01"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Żywności; Pracownia Badań Mikrobiologicznych Żywności","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kosmetyki Liczba bakterii tlenowych mezofilnych\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 21149:2017-07 +A1:2023-01 Kosmetyki Liczba bakterii tlenowych mezofilnych\nMetoda plytkowa (posiew wglebny) PN-EN ISO 21149:2017-07 +A1:2023-01","categories":["microbiology","pharma"],"row_index":79,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Aerobic mesophilic bacteria count","search_en":"Cosmetics Aerobic mesophilic bacteria count Plate method (pour plate) PN-EN ISO 21149:2017-07 +A1:2023-01","technique_en":"Plate method (pour plate)","test_object_en":"Cosmetics","search_zh":"化妆品 嗜温需氧菌数 平板法（倾注培养） PN-EN ISO 21149:2017-07 +A1:2023-01","technique_zh":"平板法（倾注培养）","test_object_zh":"化妆品","methodology_zh":"嗜温需氧菌数"},{"_id":"6a836ff8af14b9c0e7b1ee17","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Kosmetyki","methodology":"Liczba drożdży i pleśni","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba drożdży i pleśni\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 16212:2017-08 +A1:2023-01","norm_bases":["PN-EN ISO 16212:2017-08 +A1:2023-01"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Żywności; Pracownia Badań Mikrobiologicznych Żywności","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kosmetyki Liczba drożdży i pleśni\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 16212:2017-08 +A1:2023-01 Kosmetyki Liczba drozdzy i plesni\nMetoda plytkowa (posiew wglebny) PN-EN ISO 16212:2017-08 +A1:2023-01","categories":["pharma"],"row_index":80,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Yeast and mould count","search_en":"Cosmetics Yeast and mould count Plate method (pour plate) PN-EN ISO 16212:2017-08 +A1:2023-01","technique_en":"Plate method (pour plate)","test_object_en":"Cosmetics","methodology_zh":"酵母菌与霉菌计数","search_zh":"化妆品 酵母菌与霉菌计数 平板法（倾注培养） PN-EN ISO 16212:2017-08 +A1:2023-01","technique_zh":"平板法（倾注培养）","test_object_zh":"化妆品"},{"_id":"6a836ff8af14b9c0e7b1ee18","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Żywność E","methodology":"Obecność Listeria monocytogenes","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność Listeria monocytogenes\nMetoda hodowlana z potwierdzeniem biochemicznym","reference":"PN-EN ISO 11290-1","norm_bases":["PN-EN ISO 11290-1"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Żywności; Pracownia Badań Mikrobiologicznych Żywności","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniona publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Obecność Listeria monocytogenes\nMetoda hodowlana z potwierdzeniem biochemicznym PN-EN ISO 11290-1 Zywnosc E Obecnosc Listeria monocytogenes\nMetoda hodowlana z potwierdzeniem biochemicznym PN-EN ISO 11290-1","categories":["food","microbiology"],"row_index":81,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of Listeria monocytogenes","search_en":"Food E Presence of Listeria monocytogenes Culture method with biochemical confirmation PN-EN ISO 11290-1","technique_en":"Culture method with biochemical confirmation","test_object_en":"Food E","search_zh":"食品 E 单核细胞增生李斯特氏菌的检出 培养法结合生化确认 PN-EN ISO 11290-1","technique_zh":"培养法结合生化确认","test_object_zh":"食品 E","methodology_zh":"单核细胞增生李斯特氏菌的检出"},{"_id":"6a836ff8af14b9c0e7b1ee19","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Żywność E","methodology":"Obecność Salmonella spp.","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność Salmonella spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PN-EN ISO 6579-1","norm_bases":["PN-EN ISO 6579-1"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Żywności; Pracownia Badań Mikrobiologicznych Żywności","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniona publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Obecność Salmonella spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579-1 Zywnosc E Obecnosc Salmonella spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579-1","categories":["microbiology","food"],"row_index":82,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of Salmonella spp.","search_en":"Food E Presence of Salmonella spp. Culture method with biochemical and serological confirmation PN-EN ISO 6579-1","technique_en":"Culture method with biochemical and serological confirmation","test_object_en":"Food E","methodology_zh":"沙门氏菌属（Salmonella spp.）的检出","search_zh":"食品 E 沙门氏菌属（Salmonella spp.）的检出 培养法结合生化与血清学确认 PN-EN ISO 6579-1","technique_zh":"培养法结合生化与血清学确认","test_object_zh":"食品 E"},{"_id":"6a836ff8af14b9c0e7b1ee1a","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Żywność E","methodology":"Liczba bakterii z grupy coli","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba bakterii z grupy coli\nMetoda płytkowa (posiew wgłębny)","reference":"PN-ISO 4832","norm_bases":["PN-ISO 4832"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Żywności; Pracownia Badań Mikrobiologicznych Żywności","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniona publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Liczba bakterii z grupy coli\nMetoda płytkowa (posiew wgłębny) PN-ISO 4832 Zywnosc E Liczba bakterii z grupy coli\nMetoda plytkowa (posiew wglebny) PN-ISO 4832","categories":["food","microbiology"],"row_index":83,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Coliform bacteria count","search_en":"Food E Coliform bacteria count Plate method (pour plate) PN-ISO 4832","technique_en":"Plate method (pour plate)","test_object_en":"Food E","search_zh":"食品 E 大肠菌群计数 平板法（倾注培养） PN-ISO 4832","technique_zh":"平板法（倾注培养）","test_object_zh":"食品 E","methodology_zh":"大肠菌群计数"},{"_id":"6a836ff8af14b9c0e7b1ee1b","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Żywność E","methodology":"Liczba β-glukuronidazo-dodatnich Escherichia coli","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba β-glukuronidazo-dodatnich Escherichia coli\nMetoda płytkowa (posiew wgłębny)","reference":"PN-ISO 16649-2","norm_bases":["PN-ISO 16649-2"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Żywności; Pracownia Badań Mikrobiologicznych Żywności","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniona publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Liczba β-glukuronidazo-dodatnich Escherichia coli\nMetoda płytkowa (posiew wgłębny) PN-ISO 16649-2 Zywnosc E Liczba β-glukuronidazo-dodatnich Escherichia coli\nMetoda plytkowa (posiew wglebny) PN-ISO 16649-2","categories":["food","microbiology"],"row_index":84,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Count of β-glucuronidase-positive Escherichia coli","search_en":"Food E Count of β-glucuronidase-positive Escherichia coli Plate method (pour plate) PN-ISO 16649-2","technique_en":"Plate method (pour plate)","test_object_en":"Food E","search_zh":"食品 E 平板法（倾注培养） PN-ISO 16649-2","technique_zh":"平板法（倾注培养）","test_object_zh":"食品 E"},{"_id":"6a836ff8af14b9c0e7b1ee1c","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Żywność E","methodology":"Liczba gronkowców koagulazo-dodatnich (Staphylococcus aureus i innych gatunków)","parameters":[],"technique":"Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda płytkowa (posiew powierzchniowy)"],"computed":[],"activity":"Liczba gronkowców koagulazo-dodatnich (Staphylococcus aureus i innych gatunków)\nMetoda płytkowa (posiew powierzchniowy)","reference":"PN-EN ISO 6888-1","norm_bases":["PN-EN ISO 6888-1"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Żywności; Pracownia Badań Mikrobiologicznych Żywności","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniona publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Liczba gronkowców koagulazo-dodatnich (Staphylococcus aureus i innych gatunków)\nMetoda płytkowa (posiew powierzchniowy) PN-EN ISO 6888-1 Zywnosc E Liczba gronkowcow koagulazo-dodatnich (Staphylococcus aureus i innych gatunkow)\nMetoda plytkowa (posiew powierzchniowy) PN-EN ISO 6888-1","categories":["food"],"row_index":85,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Coagulase-positive staphylococci count (Staphylococcus aureus and other species)","search_en":"Food E Coagulase-positive staphylococci count (Staphylococcus aureus and other species) Plate method (spread plate) PN-EN ISO 6888-1","technique_en":"Plate method (spread plate)","test_object_en":"Food E","search_zh":"食品 E 凝固酶阳性葡萄球菌数（金黄色葡萄球菌及其他菌种） 平板法（表面涂布） PN-EN ISO 6888-1","technique_zh":"平板法（表面涂布）","test_object_zh":"食品 E","methodology_zh":"凝固酶阳性葡萄球菌数（金黄色葡萄球菌及其他菌种）"},{"_id":"6a836ff8af14b9c0e7b1ee1d","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Żywność o aktywności wody wyższej niż 0,95 E","methodology":"Liczba drożdży i pleśni","parameters":[],"technique":"Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda płytkowa (posiew powierzchniowy)"],"computed":[],"activity":"Liczba drożdży i pleśni\nMetoda płytkowa (posiew powierzchniowy)","reference":"PN-ISO 21527-1","norm_bases":["PN-ISO 21527-1"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Żywności; Pracownia Badań Mikrobiologicznych Żywności","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniona publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność o aktywności wody wyższej niż 0,95 E Liczba drożdży i pleśni\nMetoda płytkowa (posiew powierzchniowy) PN-ISO 21527-1 Zywnosc o aktywnosci wody wyzszej niz 0,95 E Liczba drozdzy i plesni\nMetoda plytkowa (posiew powierzchniowy) PN-ISO 21527-1","categories":["water","food"],"row_index":86,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Yeast and mould count","search_en":"Food with water activity higher than 0,95 E Yeast and mould count Plate method (spread plate) PN-ISO 21527-1","technique_en":"Plate method (spread plate)","test_object_en":"Food with water activity higher than 0,95 E","methodology_zh":"酵母菌与霉菌计数","search_zh":"酵母菌与霉菌计数 平板法（表面涂布） PN-ISO 21527-1","technique_zh":"平板法（表面涂布）"},{"_id":"6a836ff8af14b9c0e7b1ee1e","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Żywność o aktywności wody niższej lub równej 0,95 E","methodology":"Liczba drożdży i pleśni","parameters":[],"technique":"Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda płytkowa (posiew powierzchniowy)"],"computed":[],"activity":"Liczba drożdży i pleśni\nMetoda płytkowa (posiew powierzchniowy)","reference":"PN-ISO 21527-2","norm_bases":["PN-ISO 21527-2"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Żywności; Pracownia Badań Mikrobiologicznych Żywności","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniona publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność o aktywności wody niższej lub równej 0,95 E Liczba drożdży i pleśni\nMetoda płytkowa (posiew powierzchniowy) PN-ISO 21527-2 Zywnosc o aktywnosci wody nizszej lub rownej 0,95 E Liczba drozdzy i plesni\nMetoda plytkowa (posiew powierzchniowy) PN-ISO 21527-2","categories":["water","food"],"row_index":87,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Yeast and mould count","search_en":"Food with a water activity lower than or equal to 0,95 E Yeast and mould count Plate method (spread plate) PN-ISO 21527-2","technique_en":"Plate method (spread plate)","test_object_en":"Food with a water activity lower than or equal to 0,95 E","methodology_zh":"酵母菌与霉菌计数","search_zh":"酵母菌与霉菌计数 平板法（表面涂布） PN-ISO 21527-2","technique_zh":"平板法（表面涂布）"},{"_id":"6a836ff8af14b9c0e7b1ee1f","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Żywność E","methodology":"Liczba przypuszczalnych Bacillus cereus","parameters":[],"technique":"Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda płytkowa (posiew powierzchniowy)"],"computed":[],"activity":"Liczba przypuszczalnych Bacillus cereus\nMetoda płytkowa (posiew powierzchniowy)","reference":"PN-EN ISO 7932","norm_bases":["PN-EN ISO 7932"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Żywności; Pracownia Badań Mikrobiologicznych Żywności","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniona publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Liczba przypuszczalnych Bacillus cereus\nMetoda płytkowa (posiew powierzchniowy) PN-EN ISO 7932 Zywnosc E Liczba przypuszczalnych Bacillus cereus\nMetoda plytkowa (posiew powierzchniowy) PN-EN ISO 7932","categories":["food"],"row_index":88,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presumptive Bacillus cereus count","search_en":"Food E Presumptive Bacillus cereus count Plate method (spread plate) PN-EN ISO 7932","technique_en":"Plate method (spread plate)","test_object_en":"Food E","search_zh":"食品 E 蜡样芽孢杆菌推定计数 平板法（表面涂布） PN-EN ISO 7932","technique_zh":"平板法（表面涂布）","test_object_zh":"食品 E","methodology_zh":"蜡样芽孢杆菌推定计数"},{"_id":"6a836ff8af14b9c0e7b1ee20","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Żywność E","methodology":"Ogólna liczba drobnoustrojów","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 4833-1","norm_bases":["PN-EN ISO 4833-1"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Żywności; Pracownia Badań Mikrobiologicznych Żywności","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniona publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Ogólna liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 4833-1 Zywnosc E Ogolna liczba drobnoustrojow\nMetoda plytkowa (posiew wglebny) PN-EN ISO 4833-1","categories":["food","microbiology"],"row_index":89,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total viable count","search_en":"Food E Total viable count Plate method (pour plate) PN-EN ISO 4833-1","technique_en":"Plate method (pour plate)","test_object_en":"Food E","methodology_zh":"微生物总数","search_zh":"食品 E 微生物总数 平板法（倾注培养） PN-EN ISO 4833-1","technique_zh":"平板法（倾注培养）","test_object_zh":"食品 E"},{"_id":"6a836ff8af14b9c0e7b1ee21","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Żywność E","methodology":"Liczba Listeria monocytogenes","parameters":[],"technique":"Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda płytkowa (posiew powierzchniowy)"],"computed":[],"activity":"Liczba Listeria monocytogenes\nMetoda płytkowa (posiew powierzchniowy)","reference":"PN-EN ISO 11290-2","norm_bases":["PN-EN ISO 11290-2"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Żywności; Pracownia Badań Mikrobiologicznych Żywności","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniona publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Liczba Listeria monocytogenes\nMetoda płytkowa (posiew powierzchniowy) PN-EN ISO 11290-2 Zywnosc E Liczba Listeria monocytogenes\nMetoda plytkowa (posiew powierzchniowy) PN-EN ISO 11290-2","categories":["food","microbiology"],"row_index":90,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Listeria monocytogenes count","search_en":"Food E Listeria monocytogenes count Plate method (spread plate) PN-EN ISO 11290-2","technique_en":"Plate method (spread plate)","test_object_en":"Food E","search_zh":"食品 E 单核细胞增生李斯特氏菌计数 平板法（表面涂布） PN-EN ISO 11290-2","technique_zh":"平板法（表面涂布）","test_object_zh":"食品 E","methodology_zh":"单核细胞增生李斯特氏菌计数"},{"_id":"6a836ff8af14b9c0e7b1ee22","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Żywność E","methodology":"Liczba Enterobacteriaceae","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba Enterobacteriaceae\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 21528-2","norm_bases":["PN-EN ISO 21528-2"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Żywności; Pracownia Badań Mikrobiologicznych Żywności","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniona publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Liczba Enterobacteriaceae\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 21528-2 Zywnosc E Liczba Enterobacteriaceae\nMetoda plytkowa (posiew wglebny) PN-EN ISO 21528-2","categories":["food"],"row_index":91,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Enterobacteriaceae count","search_en":"Food E Enterobacteriaceae count Plate method (pour plate) PN-EN ISO 21528-2","technique_en":"Plate method (pour plate)","test_object_en":"Food E","methodology_zh":"肠杆菌科（Enterobacteriaceae）计数","search_zh":"食品 E 肠杆菌科（Enterobacteriaceae）计数 平板法（倾注培养） PN-EN ISO 21528-2","technique_zh":"平板法（倾注培养）","test_object_zh":"食品 E"},{"_id":"6a836ff8af14b9c0e7b1ee23","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Żywność E","methodology":"Obecność Campylobacter spp.","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i mikroskopowym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i mikroskopowym"],"computed":[],"activity":"Obecność Campylobacter spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i mikroskopowym","reference":"PN-EN ISO 10272-1","norm_bases":["PN-EN ISO 10272-1"],"lab_section":"Dział Laboratoryjny/ Oddział Badania Żywności; Pracownia Badań Mikrobiologicznych Żywności","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniona publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Obecność Campylobacter spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i mikroskopowym PN-EN ISO 10272-1 Zywnosc E Obecnosc Campylobacter spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i mikroskopowym PN-EN ISO 10272-1","categories":["food"],"row_index":92,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of Campylobacter spp.","search_en":"Food E Presence of Campylobacter spp. Culture method with biochemical and microscopic confirmation PN-EN ISO 10272-1","technique_en":"Culture method with biochemical and microscopic confirmation","test_object_en":"Food E","search_zh":"食品 E 弯曲杆菌属的检出 培养法（附生化与显微确证） PN-EN ISO 10272-1","test_object_zh":"食品 E","technique_zh":"培养法（附生化与显微确证）","methodology_zh":"弯曲杆菌属的检出"},{"_id":"6a836ff8af14b9c0e7b1ee24","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Kał, wymaz z odbytu, krew, mocz, żółć oraz szczepy bakteryjne","methodology":"Obecność i identyfikacja pałeczek z rodzaju Salmonella, Shigella","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność i identyfikacja pałeczek z rodzaju Salmonella, Shigella\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PB-01 wydanie 08 z dnia 01.12.2021 r. | na podstawie metodyk Państwowego Zakładu Higieny","norm_bases":["PB-01 wydanie 08 z dnia 01.12.2021 r.","na podstawie metodyk Państwowego Zakładu Higieny"],"lab_section":"Dział Laboratoryjny/ Oddział Mikrobiologii i Parazytologii; Pracownia Schorzeń Jelitowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kał, wymaz z odbytu, krew, mocz, żółć oraz szczepy bakteryjne Obecność i identyfikacja pałeczek z rodzaju Salmonella, Shigella\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB-01 wydanie 08 z dnia 01.12.2021 r. | na podstawie metodyk Państwowego Zakładu Higieny Kal, wymaz z odbytu, krew, mocz, zolc oraz szczepy bakteryjne Obecnosc i identyfikacja paleczek z rodzaju Salmonella, Shigella\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB-01 wydanie 08 z dnia 01.12.2021 r. | na podstawie metodyk Panstwowego Zakladu Higieny","categories":["microbiology"],"row_index":93,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence and identification of rods of the genera Salmonella, Shigella","search_en":"Faeces, rectal swab, blood, urine, bile and bacterial strains Presence and identification of rods of the genera Salmonella, Shigella Culture method with biochemical and serological confirmation PB-01 wydanie 08 z dnia 01.12.2021 r. | na podstawie metodyk Państwowego Zakładu Higieny","technique_en":"Culture method with biochemical and serological confirmation","test_object_en":"Faeces, rectal swab, blood, urine, bile and bacterial strains","search_zh":"沙门氏菌属与志贺氏菌属的检出与鉴定 培养法结合生化与血清学确认 PB-01 wydanie 08 z dnia 01.12.2021 r. | na podstawie metodyk Państwowego Zakładu Higieny","technique_zh":"培养法结合生化与血清学确认","methodology_zh":"沙门氏菌属与志贺氏菌属的检出与鉴定"},{"_id":"6a836ff8af14b9c0e7b1ee25","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Kał, wymaz z odbytu oraz szczepy bakteryjne E","methodology":"Obecność i identyfikacja wybranych tlenowych i mikroaerofilnych czynników etiologicznych zakażeń przewodu pokarmowego innych niż Salmonella, Shigella","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność i identyfikacja wybranych tlenowych i mikroaerofilnych czynników etiologicznych zakażeń przewodu pokarmowego innych niż Salmonella, Shigella\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PB-17 | na podstawie metodyk Państwowego Zakładu Higieny, instrukcji producenta testu diagnostycznego","norm_bases":["PB-17","na podstawie metodyk Państwowego Zakładu Higieny, instrukcji producenta testu diagnostycznego"],"lab_section":"Dział Laboratoryjny/ Oddział Mikrobiologii i Parazytologii; Pracownia Schorzeń Jelitowych","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniona publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Kał, wymaz z odbytu oraz szczepy bakteryjne E Obecność i identyfikacja wybranych tlenowych i mikroaerofilnych czynników etiologicznych zakażeń przewodu pokarmowego innych niż Salmonella, Shigella\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB-17 | na podstawie metodyk Państwowego Zakładu Higieny, instrukcji producenta testu diagnostycznego Kal, wymaz z odbytu oraz szczepy bakteryjne E Obecnosc i identyfikacja wybranych tlenowych i mikroaerofilnych czynnikow etiologicznych zakazen przewodu pokarmowego innych niz Salmonella, Shigella\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB-17 | na podstawie metodyk Panstwowego Zakladu Higieny, instrukcji producenta testu diagnostycznego","categories":["microbiology"],"row_index":94,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence and identification of selected aerobic and microaerophilic aetiological agents of gastrointestinal infections other than Salmonella, Shigella","search_en":"Faeces, rectal swab and bacterial strains E Presence and identification of selected aerobic and microaerophilic aetiological agents of gastrointestinal infections other than Salmonella, Shigella Culture method with biochemical and serological confirmation PB-17 | na podstawie metodyk Państwowego Zakładu Higieny, instrukcji producenta testu diagnostycznego","technique_en":"Culture method with biochemical and serological confirmation","test_object_en":"Faeces, rectal swab and bacterial strains E","search_zh":"培养法结合生化与血清学确认 PB-17 | na podstawie metodyk Państwowego Zakładu Higieny, instrukcji producenta testu diagnostycznego","technique_zh":"培养法结合生化与血清学确认"},{"_id":"6a836ff8af14b9c0e7b1ee26","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Krew, surowica","methodology":"Obecność przeciwciał przeciwko krętkom z rodzaju Leptospira","parameters":[],"technique":"Metoda aglutynacji mikroskopowej MAT","techniques":["Metoda aglutynacji mikroskopowej MAT"],"computed":[],"activity":"Obecność przeciwciał przeciwko krętkom z rodzaju Leptospira\nMetoda aglutynacji mikroskopowej MAT","reference":"PB-05 wydanie 06 z dnia 01.12.2021 r. | na podstawie metodyki WHO, publikacji J. Zwierz „Leptospirozy”","norm_bases":["PB-05 wydanie 06 z dnia 01.12.2021 r.","na podstawie metodyki WHO, publikacji J. Zwierz „Leptospirozy”"],"lab_section":"Dział Laboratoryjny/ Oddział Mikrobiologii i Parazytologii; Pracownia Bakteriologii Ogólnej i Parazytologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Krew, surowica Obecność przeciwciał przeciwko krętkom z rodzaju Leptospira\nMetoda aglutynacji mikroskopowej MAT PB-05 wydanie 06 z dnia 01.12.2021 r. | na podstawie metodyki WHO, publikacji J. Zwierz „Leptospirozy” Krew, surowica Obecnosc przeciwcial przeciwko kretkom z rodzaju Leptospira\nMetoda aglutynacji mikroskopowej MAT PB-05 wydanie 06 z dnia 01.12.2021 r. | na podstawie metodyki WHO, publikacji J. Zwierz „Leptospirozy”","categories":["other"],"row_index":95,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of antibodies against spirochaetes of the genus Leptospira","search_en":"Blood, serum Presence of antibodies against spirochaetes of the genus Leptospira Microscopic agglutination method MAT PB-05 wydanie 06 z dnia 01.12.2021 r. | na podstawie metodyki WHO, publikacji J. Zwierz „Leptospirozy”","technique_en":"Microscopic agglutination method MAT","test_object_en":"Blood, serum"},{"_id":"6a836ff8af14b9c0e7b1ee27","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Kał E","methodology":"Obecność antygenu Giardia lamblia","parameters":[],"technique":"Metoda immunoenzymatyczna","techniques":["Metoda immunoenzymatyczna"],"computed":[],"activity":"Obecność antygenu Giardia lamblia\nMetoda immunoenzymatyczna","reference":"PB-13 | na podstawie instrukcji producenta testu diagnostycznego","norm_bases":["PB-13","na podstawie instrukcji producenta testu diagnostycznego"],"lab_section":"Dział Laboratoryjny/ Oddział Mikrobiologii i Parazytologii; Pracownia Bakteriologii Ogólnej i Parazytologii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniona publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Kał E Obecność antygenu Giardia lamblia\nMetoda immunoenzymatyczna PB-13 | na podstawie instrukcji producenta testu diagnostycznego Kal E Obecnosc antygenu Giardia lamblia\nMetoda immunoenzymatyczna PB-13 | na podstawie instrukcji producenta testu diagnostycznego","categories":["other"],"row_index":96,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of Giardia lamblia antigen","search_en":"Faeces E Presence of Giardia lamblia antigen Enzyme immunoassay method PB-13 | na podstawie instrukcji producenta testu diagnostycznego","technique_en":"Enzyme immunoassay method","test_object_en":"Faeces E","search_zh":"粪便 E 酶联免疫法 PB-13 | na podstawie instrukcji producenta testu diagnostycznego","technique_zh":"酶联免疫法","test_object_zh":"粪便 E"},{"_id":"6a836ff8af14b9c0e7b1ee28","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Materiał biologiczny E","methodology":"Obecność i identyfikacja trofozoitów, cyst, jaj, larw, postaci dorosłych pasożytów jelitowych","parameters":[],"technique":"Metoda mikroskopowa, metoda makroskopowa","techniques":["Metoda mikroskopowa, metoda makroskopowa"],"computed":[],"activity":"Obecność i identyfikacja trofozoitów, cyst, jaj, larw, postaci dorosłych pasożytów jelitowych\nMetoda mikroskopowa, metoda makroskopowa","reference":"PB-02 wydanie 06 z dnia 01.12.2021 r. | na podstawie A. Buczek „Atlas pasożytów człowieka”, J. Błaszkowska, T. Ferenc, P. Kurnatowski „Zarys parazytologii medycznej”.","norm_bases":["PB-02 wydanie 06 z dnia 01.12.2021 r.","na podstawie A. Buczek „Atlas pasożytów człowieka”, J. Błaszkowska, T. Ferenc, P. Kurnatowski „Zarys parazytologii medycznej”."],"lab_section":"Dział Laboratoryjny/ Oddział Mikrobiologii i Parazytologii; Pracownia Bakteriologii Ogólnej i Parazytologii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniona publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Materiał biologiczny E Obecność i identyfikacja trofozoitów, cyst, jaj, larw, postaci dorosłych pasożytów jelitowych\nMetoda mikroskopowa, metoda makroskopowa PB-02 wydanie 06 z dnia 01.12.2021 r. | na podstawie A. Buczek „Atlas pasożytów człowieka”, J. Błaszkowska, T. Ferenc, P. Kurnatowski „Zarys parazytologii medycznej”. Material biologiczny E Obecnosc i identyfikacja trofozoitow, cyst, jaj, larw, postaci doroslych pasozytow jelitowych\nMetoda mikroskopowa, metoda makroskopowa PB-02 wydanie 06 z dnia 01.12.2021 r. | na podstawie A. Buczek „Atlas pasozytow czlowieka”, J. Blaszkowska, T. Ferenc, P. Kurnatowski „Zarys parazytologii medycznej”.","categories":["materials"],"row_index":97,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence and identification of trophozoites, cysts, eggs, larvae, adult forms of intestinal parasites","search_en":"Biological material E Presence and identification of trophozoites, cysts, eggs, larvae, adult forms of intestinal parasites Microscopic method, macroscopic method PB-02 wydanie 06 z dnia 01.12.2021 r. | na podstawie A. Buczek „Atlas pasożytów człowieka”, J. Błaszkowska, T. Ferenc, P. Kurnatowski „Zarys parazytologii medycznej”.","technique_en":"Microscopic method, macroscopic method","test_object_en":"Biological material E","search_zh":"生物材料 E PB-02 wydanie 06 z dnia 01.12.2021 r. | na podstawie A. Buczek „Atlas pasożytów człowieka”, J. Błaszkowska, T. Ferenc, P. Kurnatowski „Zarys parazytologii medycznej”.","test_object_zh":"生物材料 E"},{"_id":"6a836ff8af14b9c0e7b1ee29","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Próbki środowiskowe - wymaz","methodology":"Obecność i identyfikacja bakterii","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność i identyfikacja bakterii\nMetoda hodowlana z potwierdzeniem biochemicznym","reference":"PB-06 wydanie 06 z dnia 01.12.2021 r. | na podstawie uznanych wydawnictw metodycznych, dokumentów normatywnych, instrukcji producenta zestawów diagnostycznych","norm_bases":["PB-06 wydanie 06 z dnia 01.12.2021 r.","na podstawie uznanych wydawnictw metodycznych, dokumentów normatywnych, instrukcji producenta zestawów diagnostycznych"],"lab_section":"Dział Laboratoryjny/ Oddział Mikrobiologii i Parazytologii; Pracownia Badań Czystościowych i Szkodliwych Czynników Biologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Próbki środowiskowe - wymaz Obecność i identyfikacja bakterii\nMetoda hodowlana z potwierdzeniem biochemicznym PB-06 wydanie 06 z dnia 01.12.2021 r. | na podstawie uznanych wydawnictw metodycznych, dokumentów normatywnych, instrukcji producenta zestawów diagnostycznych Probki srodowiskowe - wymaz Obecnosc i identyfikacja bakterii\nMetoda hodowlana z potwierdzeniem biochemicznym PB-06 wydanie 06 z dnia 01.12.2021 r. | na podstawie uznanych wydawnictw metodycznych, dokumentow normatywnych, instrukcji producenta zestawow diagnostycznych","categories":["environment","microbiology"],"row_index":98,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence and identification of bacteria","search_en":"Environmental samples - swab Presence and identification of bacteria Culture method with biochemical confirmation PB-06 wydanie 06 z dnia 01.12.2021 r. | na podstawie uznanych wydawnictw metodycznych, dokumentów normatywnych, instrukcji producenta zestawów diagnostycznych","technique_en":"Culture method with biochemical confirmation","test_object_en":"Environmental samples - swab","search_zh":"培养法结合生化确认 PB-06 wydanie 06 z dnia 01.12.2021 r. | na podstawie uznanych wydawnictw metodycznych, dokumentów normatywnych, instrukcji producenta zestawów diagnostycznych","technique_zh":"培养法结合生化确认"},{"_id":"6a836ff8af14b9c0e7b1ee2a","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Próbki środowiskowe - wymaz","methodology":"Obecność pleśni i drożdży","parameters":[],"technique":"Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda płytkowa (posiew powierzchniowy)"],"computed":[],"activity":"Obecność pleśni i drożdży\nMetoda płytkowa (posiew powierzchniowy)","reference":"PB-06 wydanie 06 z dnia 01.12.2021 r. | na podstawie uznanych wydawnictw metodycznych, dokumentów normatywnych, instrukcji producenta zestawów diagnostycznych","norm_bases":["PB-06 wydanie 06 z dnia 01.12.2021 r.","na podstawie uznanych wydawnictw metodycznych, dokumentów normatywnych, instrukcji producenta zestawów diagnostycznych"],"lab_section":"Dział Laboratoryjny/ Oddział Mikrobiologii i Parazytologii; Pracownia Badań Czystościowych i Szkodliwych Czynników Biologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Próbki środowiskowe - wymaz Obecność pleśni i drożdży\nMetoda płytkowa (posiew powierzchniowy) PB-06 wydanie 06 z dnia 01.12.2021 r. | na podstawie uznanych wydawnictw metodycznych, dokumentów normatywnych, instrukcji producenta zestawów diagnostycznych Probki srodowiskowe - wymaz Obecnosc plesni i drozdzy\nMetoda plytkowa (posiew powierzchniowy) PB-06 wydanie 06 z dnia 01.12.2021 r. | na podstawie uznanych wydawnictw metodycznych, dokumentow normatywnych, instrukcji producenta zestawow diagnostycznych","categories":["environment"],"row_index":99,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of moulds and yeasts","search_en":"Environmental samples - swab Presence of moulds and yeasts Plate method (spread plate) PB-06 wydanie 06 z dnia 01.12.2021 r. | na podstawie uznanych wydawnictw metodycznych, dokumentów normatywnych, instrukcji producenta zestawów diagnostycznych","technique_en":"Plate method (spread plate)","test_object_en":"Environmental samples - swab","search_zh":"平板法（表面涂布） PB-06 wydanie 06 z dnia 01.12.2021 r. | na podstawie uznanych wydawnictw metodycznych, dokumentów normatywnych, instrukcji producenta zestawów diagnostycznych","technique_zh":"平板法（表面涂布）"},{"_id":"6a836ff8af14b9c0e7b1ee2b","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Próbki środowiskowe - odcisk z powierzchni","methodology":"Liczba bakterii","parameters":[],"technique":"Metoda płytek kontaktowych","techniques":["Metoda płytek kontaktowych"],"computed":[],"activity":"Liczba bakterii\nMetoda płytek kontaktowych","reference":"PB-06 wydanie 06 z dnia 01.12.2021 r. | na podstawie uznanych wydawnictw metodycznych, dokumentów normatywnych, instrukcji producenta zestawów diagnostycznych","norm_bases":["PB-06 wydanie 06 z dnia 01.12.2021 r.","na podstawie uznanych wydawnictw metodycznych, dokumentów normatywnych, instrukcji producenta zestawów diagnostycznych"],"lab_section":"Dział Laboratoryjny/ Oddział Mikrobiologii i Parazytologii; Pracownia Badań Czystościowych i Szkodliwych Czynników Biologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Próbki środowiskowe - odcisk z powierzchni Liczba bakterii\nMetoda płytek kontaktowych PB-06 wydanie 06 z dnia 01.12.2021 r. | na podstawie uznanych wydawnictw metodycznych, dokumentów normatywnych, instrukcji producenta zestawów diagnostycznych Probki srodowiskowe - odcisk z powierzchni Liczba bakterii\nMetoda plytek kontaktowych PB-06 wydanie 06 z dnia 01.12.2021 r. | na podstawie uznanych wydawnictw metodycznych, dokumentow normatywnych, instrukcji producenta zestawow diagnostycznych","categories":["environment","microbiology"],"row_index":100,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Bacteria count","search_en":"Environmental samples - surface imprint Bacteria count Contact plate method PB-06 wydanie 06 z dnia 01.12.2021 r. | na podstawie uznanych wydawnictw metodycznych, dokumentów normatywnych, instrukcji producenta zestawów diagnostycznych","technique_en":"Contact plate method","test_object_en":"Environmental samples - surface imprint","search_zh":"细菌数 接触平皿法 PB-06 wydanie 06 z dnia 01.12.2021 r. | na podstawie uznanych wydawnictw metodycznych, dokumentów normatywnych, instrukcji producenta zestawów diagnostycznych","technique_zh":"接触平皿法","methodology_zh":"细菌数"},{"_id":"6a836ff8af14b9c0e7b1ee2c","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Próbki środowiskowe - odcisk z powierzchni","methodology":"Liczba grzybów","parameters":[],"technique":"Metoda płytek kontaktowych","techniques":["Metoda płytek kontaktowych"],"computed":[],"activity":"Liczba grzybów\nMetoda płytek kontaktowych","reference":"PB-06 wydanie 06 z dnia 01.12.2021 r. | na podstawie uznanych wydawnictw metodycznych, dokumentów normatywnych, instrukcji producenta zestawów diagnostycznych","norm_bases":["PB-06 wydanie 06 z dnia 01.12.2021 r.","na podstawie uznanych wydawnictw metodycznych, dokumentów normatywnych, instrukcji producenta zestawów diagnostycznych"],"lab_section":"Dział Laboratoryjny/ Oddział Mikrobiologii i Parazytologii; Pracownia Badań Czystościowych i Szkodliwych Czynników Biologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Próbki środowiskowe - odcisk z powierzchni Liczba grzybów\nMetoda płytek kontaktowych PB-06 wydanie 06 z dnia 01.12.2021 r. | na podstawie uznanych wydawnictw metodycznych, dokumentów normatywnych, instrukcji producenta zestawów diagnostycznych Probki srodowiskowe - odcisk z powierzchni Liczba grzybow\nMetoda plytek kontaktowych PB-06 wydanie 06 z dnia 01.12.2021 r. | na podstawie uznanych wydawnictw metodycznych, dokumentow normatywnych, instrukcji producenta zestawow diagnostycznych","categories":["environment","microbiology"],"row_index":101,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fungal count","search_en":"Environmental samples - surface imprint Fungal count Contact plate method PB-06 wydanie 06 z dnia 01.12.2021 r. | na podstawie uznanych wydawnictw metodycznych, dokumentów normatywnych, instrukcji producenta zestawów diagnostycznych","technique_en":"Contact plate method","test_object_en":"Environmental samples - surface imprint","search_zh":"霉菌数 接触平皿法 PB-06 wydanie 06 z dnia 01.12.2021 r. | na podstawie uznanych wydawnictw metodycznych, dokumentów normatywnych, instrukcji producenta zestawów diagnostycznych","technique_zh":"接触平皿法","methodology_zh":"霉菌数"},{"_id":"6a836ff8af14b9c0e7b1ee2d","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Próbki środowiskowe - wymaz z powierzchni","methodology":"Obecność Listeria monocytogenes i innych Listeria spp.","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i mikroskopowym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i mikroskopowym"],"computed":[],"activity":"Obecność Listeria monocytogenes i innych Listeria spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i mikroskopowym","reference":"PN-EN ISO 11290-1:2017-07","norm_bases":["PN-EN ISO 11290-1:2017-07"],"lab_section":"Dział Laboratoryjny/ Oddział Mikrobiologii i Parazytologii; Pracownia Badań Czystościowych i Szkodliwych Czynników Biologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Próbki środowiskowe - wymaz z powierzchni Obecność Listeria monocytogenes i innych Listeria spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i mikroskopowym PN-EN ISO 11290-1:2017-07 Probki srodowiskowe - wymaz z powierzchni Obecnosc Listeria monocytogenes i innych Listeria spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i mikroskopowym PN-EN ISO 11290-1:2017-07","categories":["environment","microbiology"],"row_index":102,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of Listeria monocytogenes and other Listeria spp.","search_en":"Presence of Listeria monocytogenes and other Listeria spp. Culture method with biochemical and microscopic confirmation PN-EN ISO 11290-1:2017-07","technique_en":"Culture method with biochemical and microscopic confirmation","search_zh":"单核细胞增生李斯特氏菌与其他李斯特氏菌属的检出 培养法（附生化与显微确证） PN-EN ISO 11290-1:2017-07","technique_zh":"培养法（附生化与显微确证）","methodology_zh":"单核细胞增生李斯特氏菌与其他李斯特氏菌属的检出"},{"_id":"6a836ff8af14b9c0e7b1ee2e","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Próbki środowiskowe - wymaz z powierzchni","methodology":"Obecność Salmonella spp.","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność Salmonella spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PN-EN ISO 6579-1:2017-04","norm_bases":["PN-EN ISO 6579-1:2017-04"],"lab_section":"Dział Laboratoryjny/ Oddział Mikrobiologii i Parazytologii; Pracownia Badań Czystościowych i Szkodliwych Czynników Biologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Próbki środowiskowe - wymaz z powierzchni Obecność Salmonella spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579-1:2017-04 Probki srodowiskowe - wymaz z powierzchni Obecnosc Salmonella spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579-1:2017-04","categories":["microbiology","environment"],"row_index":103,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of Salmonella spp.","search_en":"Presence of Salmonella spp. Culture method with biochemical and serological confirmation PN-EN ISO 6579-1:2017-04","technique_en":"Culture method with biochemical and serological confirmation","methodology_zh":"沙门氏菌属（Salmonella spp.）的检出","search_zh":"沙门氏菌属（Salmonella spp.）的检出 培养法结合生化与血清学确认 PN-EN ISO 6579-1:2017-04","technique_zh":"培养法结合生化与血清学确认"},{"_id":"6a836ff8af14b9c0e7b1ee2f","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Powietrze","methodology":"Liczba bakterii","parameters":[],"technique":"Metoda hodowlana","techniques":["Metoda hodowlana"],"computed":[],"activity":"Liczba bakterii\nMetoda hodowlana","reference":"PB-11 wydanie 06 z dnia 01.12.2021 r. | na podstawie dokumentów normatywnych, Farmakopei Polskiej, literatury: Olga Fassatiova „Grzyby mikroskopowe w mikrobiologii technicznej” G.S. de Hong, J. Guarro, J. Gene&M.J. Figueras „Atlas of clinical fungi”","norm_bases":["PB-11 wydanie 06 z dnia 01.12.2021 r.","na podstawie dokumentów normatywnych, Farmakopei Polskiej, literatury: Olga Fassatiova „Grzyby mikroskopowe w mikrobiologii technicznej” G.S. de Hong, J. Guarro, J. Gene&M.J. Figueras „Atlas of clinical fungi”"],"lab_section":"Dział Laboratoryjny/ Oddział Mikrobiologii i Parazytologii; Pracownia Badań Czystościowych i Szkodliwych Czynników Biologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Powietrze Liczba bakterii\nMetoda hodowlana PB-11 wydanie 06 z dnia 01.12.2021 r. | na podstawie dokumentów normatywnych, Farmakopei Polskiej, literatury: Olga Fassatiova „Grzyby mikroskopowe w mikrobiologii technicznej” G.S. de Hong, J. Guarro, J. Gene&M.J. Figueras „Atlas of clinical fungi” Powietrze Liczba bakterii\nMetoda hodowlana PB-11 wydanie 06 z dnia 01.12.2021 r. | na podstawie dokumentow normatywnych, Farmakopei Polskiej, literatury: Olga Fassatiova „Grzyby mikroskopowe w mikrobiologii technicznej” G.S. de Hong, J. Guarro, J. Gene&M.J. Figueras „Atlas of clinical fungi”","categories":["microbiology","environment"],"row_index":104,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Bacteria count","search_en":"Air Bacteria count Culture method PB-11 wydanie 06 z dnia 01.12.2021 r. | na podstawie dokumentów normatywnych, Farmakopei Polskiej, literatury: Olga Fassatiova „Grzyby mikroskopowe w mikrobiologii technicznej” G.S. de Hong, J. Guarro, J. Gene&M.J. Figueras „Atlas of clinical fungi”","technique_en":"Culture method","test_object_en":"Air","search_zh":"空气 细菌数 培养法 PB-11 wydanie 06 z dnia 01.12.2021 r. | na podstawie dokumentów normatywnych, Farmakopei Polskiej, literatury: Olga Fassatiova „Grzyby mikroskopowe w mikrobiologii technicznej” G.S. de Hong, J. Guarro, J. Gene&M.J. Figueras „Atlas of clinical fungi”","technique_zh":"培养法","test_object_zh":"空气","methodology_zh":"细菌数"},{"_id":"6a836ff8af14b9c0e7b1ee30","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Powietrze","methodology":"Liczba bakterii wskaźnikowych:","parameters":[{"name":"Pseudomonas fluorescens"},{"name":"Gronkowce hemolizujące"},{"name":"Gronkowce mannitolo-dodatnie"},{"name":"Promieniowce"}],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i mikroskopowym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i mikroskopowym"],"computed":[],"activity":"Liczba bakterii wskaźnikowych:\nZakres:\nPseudomonas fluorescens\nGronkowce hemolizujące\nGronkowce mannitolo-dodatnie\nPromieniowce\nMetoda hodowlana z potwierdzeniem biochemicznym i mikroskopowym","reference":"PB-11 wydanie 06 z dnia 01.12.2021 r. | na podstawie dokumentów normatywnych, Farmakopei Polskiej, literatury: Olga Fassatiova „Grzyby mikroskopowe w mikrobiologii technicznej” G.S. de Hong, J. Guarro, J. Gene&M.J. Figueras „Atlas of clinical fungi”","norm_bases":["PB-11 wydanie 06 z dnia 01.12.2021 r.","na podstawie dokumentów normatywnych, Farmakopei Polskiej, literatury: Olga Fassatiova „Grzyby mikroskopowe w mikrobiologii technicznej” G.S. de Hong, J. Guarro, J. Gene&M.J. Figueras „Atlas of clinical fungi”"],"lab_section":"Dział Laboratoryjny/ Oddział Mikrobiologii i Parazytologii; Pracownia Badań Czystościowych i Szkodliwych Czynników Biologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Powietrze Liczba bakterii wskaźnikowych:\nZakres:\nPseudomonas fluorescens\nGronkowce hemolizujące\nGronkowce mannitolo-dodatnie\nPromieniowce\nMetoda hodowlana z potwierdzeniem biochemicznym i mikroskopowym PB-11 wydanie 06 z dnia 01.12.2021 r. | na podstawie dokumentów normatywnych, Farmakopei Polskiej, literatury: Olga Fassatiova „Grzyby mikroskopowe w mikrobiologii technicznej” G.S. de Hong, J. Guarro, J. Gene&M.J. Figueras „Atlas of clinical fungi” Powietrze Liczba bakterii wskaznikowych:\nZakres:\nPseudomonas fluorescens\nGronkowce hemolizujace\nGronkowce mannitolo-dodatnie\nPromieniowce\nMetoda hodowlana z potwierdzeniem biochemicznym i mikroskopowym PB-11 wydanie 06 z dnia 01.12.2021 r. | na podstawie dokumentow normatywnych, Farmakopei Polskiej, literatury: Olga Fassatiova „Grzyby mikroskopowe w mikrobiologii technicznej” G.S. de Hong, J. Guarro, J. Gene&M.J. Figueras „Atlas of clinical fungi”","categories":["microbiology","environment"],"row_index":105,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Count of indicator bacteria:","parameters_en":[{"name":"Pseudomonas fluorescens"},{"name":"Haemolytic staphylococci"},{"name":"Mannitol-positive staphylococci"},{"name":"Actinomycetes"}],"search_en":"Air Count of indicator bacteria: Culture method with biochemical and microscopic confirmation Pseudomonas fluorescens Haemolytic staphylococci Mannitol-positive staphylococci Actinomycetes PB-11 wydanie 06 z dnia 01.12.2021 r. | na podstawie dokumentów normatywnych, Farmakopei Polskiej, literatury: Olga Fassatiova „Grzyby mikroskopowe w mikrobiologii technicznej” G.S. de Hong, J. Guarro, J. Gene&M.J. Figueras „Atlas of clinical fungi”","technique_en":"Culture method with biochemical and microscopic confirmation","test_object_en":"Air","search_zh":"空气 培养法（附生化与显微确证） PB-11 wydanie 06 z dnia 01.12.2021 r. | na podstawie dokumentów normatywnych, Farmakopei Polskiej, literatury: Olga Fassatiova „Grzyby mikroskopowe w mikrobiologii technicznej” G.S. de Hong, J. Guarro, J. Gene&M.J. Figueras „Atlas of clinical fungi”","test_object_zh":"空气","technique_zh":"培养法（附生化与显微确证）"},{"_id":"6a836ff8af14b9c0e7b1ee31","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Powietrze","methodology":"Liczba i obecność grzybów strzępkowych i drożdżopodobnych","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem mikroskopowym","techniques":["Metoda hodowlana z potwierdzeniem mikroskopowym"],"computed":[],"activity":"Liczba i obecność grzybów strzępkowych i drożdżopodobnych\nMetoda hodowlana z potwierdzeniem mikroskopowym","reference":"PB-11 wydanie 06 z dnia 01.12.2021 r. | na podstawie dokumentów normatywnych, Farmakopei Polskiej, literatury: Olga Fassatiova „Grzyby mikroskopowe w mikrobiologii technicznej” G.S. de Hong, J. Guarro, J. Gene&M.J. Figueras „Atlas of clinical fungi”","norm_bases":["PB-11 wydanie 06 z dnia 01.12.2021 r.","na podstawie dokumentów normatywnych, Farmakopei Polskiej, literatury: Olga Fassatiova „Grzyby mikroskopowe w mikrobiologii technicznej” G.S. de Hong, J. Guarro, J. Gene&M.J. Figueras „Atlas of clinical fungi”"],"lab_section":"Dział Laboratoryjny/ Oddział Mikrobiologii i Parazytologii; Pracownia Badań Czystościowych i Szkodliwych Czynników Biologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Powietrze Liczba i obecność grzybów strzępkowych i drożdżopodobnych\nMetoda hodowlana z potwierdzeniem mikroskopowym PB-11 wydanie 06 z dnia 01.12.2021 r. | na podstawie dokumentów normatywnych, Farmakopei Polskiej, literatury: Olga Fassatiova „Grzyby mikroskopowe w mikrobiologii technicznej” G.S. de Hong, J. Guarro, J. Gene&M.J. Figueras „Atlas of clinical fungi” Powietrze Liczba i obecnosc grzybow strzepkowych i drozdzopodobnych\nMetoda hodowlana z potwierdzeniem mikroskopowym PB-11 wydanie 06 z dnia 01.12.2021 r. | na podstawie dokumentow normatywnych, Farmakopei Polskiej, literatury: Olga Fassatiova „Grzyby mikroskopowe w mikrobiologii technicznej” G.S. de Hong, J. Guarro, J. Gene&M.J. Figueras „Atlas of clinical fungi”","categories":["microbiology","environment"],"row_index":106,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Count and presence of filamentous and yeast-like fungi","search_en":"Air Count and presence of filamentous and yeast-like fungi Culture method with microscopic confirmation PB-11 wydanie 06 z dnia 01.12.2021 r. | na podstawie dokumentów normatywnych, Farmakopei Polskiej, literatury: Olga Fassatiova „Grzyby mikroskopowe w mikrobiologii technicznej” G.S. de Hong, J. Guarro, J. Gene&M.J. Figueras „Atlas of clinical fungi”","technique_en":"Culture method with microscopic confirmation","test_object_en":"Air","search_zh":"空气 培养法（附显微镜确证） PB-11 wydanie 06 z dnia 01.12.2021 r. | na podstawie dokumentów normatywnych, Farmakopei Polskiej, literatury: Olga Fassatiova „Grzyby mikroskopowe w mikrobiologii technicznej” G.S. de Hong, J. Guarro, J. Gene&M.J. Figueras „Atlas of clinical fungi”","test_object_zh":"空气","technique_zh":"培养法（附显微镜确证）"},{"_id":"6a836ff8af14b9c0e7b1ee32","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Włóknina, wyroby z włókniną (produkty higieniczne)","methodology":"Obecność Pseudomonas aeruginosa","parameters":[],"technique":"Metoda hodowlana uzupełniona testami biochemicznymi z potwierdzeniem mikroskopowym","techniques":["Metoda hodowlana uzupełniona testami biochemicznymi z potwierdzeniem mikroskopowym"],"computed":[],"activity":"Obecność Pseudomonas aeruginosa\nMetoda hodowlana uzupełniona testami biochemicznymi z potwierdzeniem mikroskopowym","reference":"PN-EN ISO 22717:2016-01+A1:2023-03","norm_bases":["PN-EN ISO 22717:2016-01+A1:2023-03"],"lab_section":"Dział Laboratoryjny/ Oddział Mikrobiologii i Parazytologii; Pracownia Badań Czystościowych i Szkodliwych Czynników Biologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Włóknina, wyroby z włókniną (produkty higieniczne) Obecność Pseudomonas aeruginosa\nMetoda hodowlana uzupełniona testami biochemicznymi z potwierdzeniem mikroskopowym PN-EN ISO 22717:2016-01+A1:2023-03 Wloknina, wyroby z wloknina (produkty higieniczne) Obecnosc Pseudomonas aeruginosa\nMetoda hodowlana uzupelniona testami biochemicznymi z potwierdzeniem mikroskopowym PN-EN ISO 22717:2016-01+A1:2023-03","categories":["other"],"row_index":107,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of Pseudomonas aeruginosa","search_en":"Nonwoven, products with nonwoven (hygiene products) Presence of Pseudomonas aeruginosa Culture method supplemented with biochemical tests and microscopic confirmation PN-EN ISO 22717:2016-01+A1:2023-03","technique_en":"Culture method supplemented with biochemical tests and microscopic confirmation","test_object_en":"Nonwoven, products with nonwoven (hygiene products)","methodology_zh":"铜绿假单胞菌（Pseudomonas aeruginosa）检出","search_zh":"非织造布、含非织造布的制品（卫生用品） 铜绿假单胞菌（Pseudomonas aeruginosa）检出 PN-EN ISO 22717:2016-01+A1:2023-03","test_object_zh":"非织造布、含非织造布的制品（卫生用品）"},{"_id":"6a836ff8af14b9c0e7b1ee33","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Włóknina, wyroby z włókniną (produkty higieniczne)","methodology":"Obecność Staphylococcus aureus","parameters":[],"technique":"Metoda hodowlana uzupełniona testami biochemicznymi z potwierdzeniem mikroskopowym","techniques":["Metoda hodowlana uzupełniona testami biochemicznymi z potwierdzeniem mikroskopowym"],"computed":[],"activity":"Obecność Staphylococcus aureus\nMetoda hodowlana uzupełniona testami biochemicznymi z potwierdzeniem mikroskopowym","reference":"PN-EN ISO 22718:2016-01+A1:2023-01","norm_bases":["PN-EN ISO 22718:2016-01+A1:2023-01"],"lab_section":"Dział Laboratoryjny/ Oddział Mikrobiologii i Parazytologii; Pracownia Badań Czystościowych i Szkodliwych Czynników Biologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Włóknina, wyroby z włókniną (produkty higieniczne) Obecność Staphylococcus aureus\nMetoda hodowlana uzupełniona testami biochemicznymi z potwierdzeniem mikroskopowym PN-EN ISO 22718:2016-01+A1:2023-01 Wloknina, wyroby z wloknina (produkty higieniczne) Obecnosc Staphylococcus aureus\nMetoda hodowlana uzupelniona testami biochemicznymi z potwierdzeniem mikroskopowym PN-EN ISO 22718:2016-01+A1:2023-01","categories":["other"],"row_index":108,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of Staphylococcus aureus","search_en":"Nonwoven, products with nonwoven (hygiene products) Presence of Staphylococcus aureus Culture method supplemented with biochemical tests and microscopic confirmation PN-EN ISO 22718:2016-01+A1:2023-01","technique_en":"Culture method supplemented with biochemical tests and microscopic confirmation","test_object_en":"Nonwoven, products with nonwoven (hygiene products)","methodology_zh":"金黄色葡萄球菌（Staphylococcus aureus）检出","search_zh":"非织造布、含非织造布的制品（卫生用品） 金黄色葡萄球菌（Staphylococcus aureus）检出 PN-EN ISO 22718:2016-01+A1:2023-01","test_object_zh":"非织造布、含非织造布的制品（卫生用品）"},{"_id":"6a836ff8af14b9c0e7b1ee34","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Włóknina, wyroby z włókniną (produkty higieniczne)","methodology":"Obecność Escherichia coli","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem mikroskopowym","techniques":["Metoda hodowlana z potwierdzeniem mikroskopowym"],"computed":[],"activity":"Obecność Escherichia coli\nMetoda hodowlana z potwierdzeniem mikroskopowym","reference":"PN-EN ISO 21150:2016-01+A1:2023-03","norm_bases":["PN-EN ISO 21150:2016-01+A1:2023-03"],"lab_section":"Dział Laboratoryjny/ Oddział Mikrobiologii i Parazytologii; Pracownia Badań Czystościowych i Szkodliwych Czynników Biologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Włóknina, wyroby z włókniną (produkty higieniczne) Obecność Escherichia coli\nMetoda hodowlana z potwierdzeniem mikroskopowym PN-EN ISO 21150:2016-01+A1:2023-03 Wloknina, wyroby z wloknina (produkty higieniczne) Obecnosc Escherichia coli\nMetoda hodowlana z potwierdzeniem mikroskopowym PN-EN ISO 21150:2016-01+A1:2023-03","categories":["microbiology"],"row_index":109,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of Escherichia coli","search_en":"Nonwoven, products with nonwoven (hygiene products) Presence of Escherichia coli Culture method with microscopic confirmation PN-EN ISO 21150:2016-01+A1:2023-03","technique_en":"Culture method with microscopic confirmation","test_object_en":"Nonwoven, products with nonwoven (hygiene products)","methodology_zh":"大肠埃希氏菌（Escherichia coli）检出","search_zh":"非织造布、含非织造布的制品（卫生用品） 大肠埃希氏菌（Escherichia coli）检出 培养法（附显微镜确证） PN-EN ISO 21150:2016-01+A1:2023-03","technique_zh":"培养法（附显微镜确证）","test_object_zh":"非织造布、含非织造布的制品（卫生用品）"},{"_id":"6a836ff8af14b9c0e7b1ee35","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Włóknina, wyroby z włókniną (produkty higieniczne)","methodology":"Obecność Candida albicans","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem mikroskopowym","techniques":["Metoda hodowlana z potwierdzeniem mikroskopowym"],"computed":[],"activity":"Obecność Candida albicans\nMetoda hodowlana z potwierdzeniem mikroskopowym","reference":"PN-EN ISO 18416:2016-01+A1:2023-03","norm_bases":["PN-EN ISO 18416:2016-01+A1:2023-03"],"lab_section":"Dział Laboratoryjny/ Oddział Mikrobiologii i Parazytologii; Pracownia Badań Czystościowych i Szkodliwych Czynników Biologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Włóknina, wyroby z włókniną (produkty higieniczne) Obecność Candida albicans\nMetoda hodowlana z potwierdzeniem mikroskopowym PN-EN ISO 18416:2016-01+A1:2023-03 Wloknina, wyroby z wloknina (produkty higieniczne) Obecnosc Candida albicans\nMetoda hodowlana z potwierdzeniem mikroskopowym PN-EN ISO 18416:2016-01+A1:2023-03","categories":["other"],"row_index":110,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of Candida albicans","search_en":"Nonwoven, products with nonwoven (hygiene products) Presence of Candida albicans Culture method with microscopic confirmation PN-EN ISO 18416:2016-01+A1:2023-03","technique_en":"Culture method with microscopic confirmation","test_object_en":"Nonwoven, products with nonwoven (hygiene products)","methodology_zh":"白色念珠菌（Candida albicans）检出","search_zh":"非织造布、含非织造布的制品（卫生用品） 白色念珠菌（Candida albicans）检出 培养法（附显微镜确证） PN-EN ISO 18416:2016-01+A1:2023-03","technique_zh":"培养法（附显微镜确证）","test_object_zh":"非织造布、含非织造布的制品（卫生用品）"},{"_id":"6a836ff8af14b9c0e7b1ee36","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Włóknina, wyroby z włókniną (produkty higieniczne)","methodology":"Liczba mezofilnych bakterii tlenowych w 1 g produktów stałych absorbujących płyny","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba mezofilnych bakterii tlenowych w 1 g produktów stałych absorbujących płyny\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 21149:2017-07","norm_bases":["PN-EN ISO 21149:2017-07"],"lab_section":"Dział Laboratoryjny/ Oddział Mikrobiologii i Parazytologii; Pracownia Badań Czystościowych i Szkodliwych Czynników Biologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Włóknina, wyroby z włókniną (produkty higieniczne) Liczba mezofilnych bakterii tlenowych w 1 g produktów stałych absorbujących płyny\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 21149:2017-07 Wloknina, wyroby z wloknina (produkty higieniczne) Liczba mezofilnych bakterii tlenowych w 1 g produktow stalych absorbujacych plyny\nMetoda plytkowa (posiew wglebny) PN-EN ISO 21149:2017-07","categories":["microbiology"],"row_index":111,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Count of mesophilic aerobic bacteria in 1 g of solid products absorbing liquids","search_en":"Nonwoven, products with nonwoven (hygiene products) Count of mesophilic aerobic bacteria in 1 g of solid products absorbing liquids Plate method (pour plate) PN-EN ISO 21149:2017-07","technique_en":"Plate method (pour plate)","test_object_en":"Nonwoven, products with nonwoven (hygiene products)","search_zh":"非织造布、含非织造布的制品（卫生用品） 平板法（倾注培养） PN-EN ISO 21149:2017-07","technique_zh":"平板法（倾注培养）","test_object_zh":"非织造布、含非织造布的制品（卫生用品）"},{"_id":"6a836ff8af14b9c0e7b1ee37","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Włóknina, wyroby z włókniną (produkty higieniczne)","methodology":"Liczba drożdży i pleśni w 1 g produktów stałych absorbujących płyny","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba drożdży i pleśni w 1 g produktów stałych absorbujących płyny\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 16212:2017-08","norm_bases":["PN-EN ISO 16212:2017-08"],"lab_section":"Dział Laboratoryjny/ Oddział Mikrobiologii i Parazytologii; Pracownia Badań Czystościowych i Szkodliwych Czynników Biologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Włóknina, wyroby z włókniną (produkty higieniczne) Liczba drożdży i pleśni w 1 g produktów stałych absorbujących płyny\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 16212:2017-08 Wloknina, wyroby z wloknina (produkty higieniczne) Liczba drozdzy i plesni w 1 g produktow stalych absorbujacych plyny\nMetoda plytkowa (posiew wglebny) PN-EN ISO 16212:2017-08","categories":["other"],"row_index":112,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Yeast and mould count in 1 g of solid products absorbing liquids","search_en":"Nonwoven, products with nonwoven (hygiene products) Yeast and mould count in 1 g of solid products absorbing liquids Plate method (pour plate) PN-EN ISO 16212:2017-08","technique_en":"Plate method (pour plate)","test_object_en":"Nonwoven, products with nonwoven (hygiene products)","search_zh":"非织造布、含非织造布的制品（卫生用品） 平板法（倾注培养） PN-EN ISO 16212:2017-08","technique_zh":"平板法（倾注培养）","test_object_zh":"非织造布、含非织造布的制品（卫生用品）"},{"_id":"6a836ff8af14b9c0e7b1ee38","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Biologiczne wskaźniki kontroli skuteczności procesu sterylizacji (testy fiolkowe) E","methodology":"Obecność drobnoustrojów wskaźnikowych Geobacillus stearothermophilus","parameters":[],"technique":"Metoda hodowlana","techniques":["Metoda hodowlana"],"computed":[],"activity":"Obecność drobnoustrojów wskaźnikowych Geobacillus stearothermophilus\nMetoda hodowlana","reference":"PB-14 | na podstawie instrukcji producenta testu diagnostycznego","norm_bases":["PB-14","na podstawie instrukcji producenta testu diagnostycznego"],"lab_section":"Dział Laboratoryjny/ Oddział Mikrobiologii i Parazytologii; Pracownia Badań Czystościowych i Szkodliwych Czynników Biologicznych","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniona publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Biologiczne wskaźniki kontroli skuteczności procesu sterylizacji (testy fiolkowe) E Obecność drobnoustrojów wskaźnikowych Geobacillus stearothermophilus\nMetoda hodowlana PB-14 | na podstawie instrukcji producenta testu diagnostycznego Biologiczne wskazniki kontroli skutecznosci procesu sterylizacji (testy fiolkowe) E Obecnosc drobnoustrojow wskaznikowych Geobacillus stearothermophilus\nMetoda hodowlana PB-14 | na podstawie instrukcji producenta testu diagnostycznego","categories":["microbiology"],"row_index":113,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of indicator microorganisms Geobacillus stearothermophilus","search_en":"Biological indicators for sterilization process efficacy control (vial tests) E Presence of indicator microorganisms Geobacillus stearothermophilus Culture method PB-14 | na podstawie instrukcji producenta testu diagnostycznego","technique_en":"Culture method","test_object_en":"Biological indicators for sterilization process efficacy control (vial tests) E","search_zh":"指示微生物嗜热脂肪土芽孢杆菌的检出 培养法 PB-14 | na podstawie instrukcji producenta testu diagnostycznego","technique_zh":"培养法","methodology_zh":"指示微生物嗜热脂肪土芽孢杆菌的检出"},{"_id":"6a836ff8af14b9c0e7b1ee39","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Materiał biologiczny E","methodology":"Obecność kwasów nukleinowych wirusów oddechowych","parameters":[],"technique":"Metoda real time PCR","techniques":["Metoda real time PCR"],"computed":[],"activity":"Obecność kwasów nukleinowych wirusów oddechowych\nMetoda real time PCR","reference":"PB-16 | na podstawie instrukcji producenta testu diagnostycznego","norm_bases":["PB-16","na podstawie instrukcji producenta testu diagnostycznego"],"lab_section":"Dział Laboratoryjny/ Oddział Mikrobiologii i Parazytologii; Pracownia Wirusologii i Serologii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniona publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Materiał biologiczny E Obecność kwasów nukleinowych wirusów oddechowych\nMetoda real time PCR PB-16 | na podstawie instrukcji producenta testu diagnostycznego Material biologiczny E Obecnosc kwasow nukleinowych wirusow oddechowych\nMetoda real time PCR PB-16 | na podstawie instrukcji producenta testu diagnostycznego","categories":["materials"],"row_index":114,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of nucleic acids of respiratory viruses","search_en":"Biological material E Presence of nucleic acids of respiratory viruses Real time PCR method PB-16 | na podstawie instrukcji producenta testu diagnostycznego","technique_en":"Real time PCR method","test_object_en":"Biological material E","search_zh":"生物材料 E 实时荧光 PCR 法 PB-16 | na podstawie instrukcji producenta testu diagnostycznego","technique_zh":"实时荧光 PCR 法","test_object_zh":"生物材料 E"},{"_id":"6a836ff8af14b9c0e7b1ee3a","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Surowica, płyn mózgowo-rdzeniowy E","methodology":"Obecność przeciwciał klasy IgM przeciwko Borrelia","parameters":[],"technique":"Metoda immunoenzymatyczna (ELISA)","techniques":["Metoda immunoenzymatyczna (ELISA)"],"computed":[],"activity":"Obecność przeciwciał klasy IgM przeciwko Borrelia\nMetoda immunoenzymatyczna (ELISA)","reference":"PB-18 | na podstawie instrukcji producenta testu diagnostycznego","norm_bases":["PB-18","na podstawie instrukcji producenta testu diagnostycznego"],"lab_section":"Dział Laboratoryjny/ Oddział Mikrobiologii i Parazytologii; Pracownia Wirusologii i Serologii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniona publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Surowica, płyn mózgowo-rdzeniowy E Obecność przeciwciał klasy IgM przeciwko Borrelia\nMetoda immunoenzymatyczna (ELISA) PB-18 | na podstawie instrukcji producenta testu diagnostycznego Surowica, plyn mozgowo-rdzeniowy E Obecnosc przeciwcial klasy IgM przeciwko Borrelia\nMetoda immunoenzymatyczna (ELISA) PB-18 | na podstawie instrukcji producenta testu diagnostycznego","categories":["other"],"row_index":115,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of IgM class antibodies against Borrelia","search_en":"Presence of IgM class antibodies against Borrelia Enzyme immunoassay method (ELISA) PB-18 | na podstawie instrukcji producenta testu diagnostycznego","technique_en":"Enzyme immunoassay method (ELISA)","search_zh":"酶联免疫吸附法（ELISA） PB-18 | na podstawie instrukcji producenta testu diagnostycznego","technique_zh":"酶联免疫吸附法（ELISA）"},{"_id":"6a836ff8af14b9c0e7b1ee3b","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Surowica, płyn mózgowo-rdzeniowy E","methodology":"Obecność przeciwciał klasy IgG przeciwko Borrelia","parameters":[],"technique":"Metoda immunoenzymatyczna (ELISA)","techniques":["Metoda immunoenzymatyczna (ELISA)"],"computed":[],"activity":"Obecność przeciwciał klasy IgG przeciwko Borrelia\nMetoda immunoenzymatyczna (ELISA)","reference":"PB-18 | na podstawie instrukcji producenta testu diagnostycznego","norm_bases":["PB-18","na podstawie instrukcji producenta testu diagnostycznego"],"lab_section":"Dział Laboratoryjny/ Oddział Mikrobiologii i Parazytologii; Pracownia Wirusologii i Serologii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniona publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Surowica, płyn mózgowo-rdzeniowy E Obecność przeciwciał klasy IgG przeciwko Borrelia\nMetoda immunoenzymatyczna (ELISA) PB-18 | na podstawie instrukcji producenta testu diagnostycznego Surowica, plyn mozgowo-rdzeniowy E Obecnosc przeciwcial klasy IgG przeciwko Borrelia\nMetoda immunoenzymatyczna (ELISA) PB-18 | na podstawie instrukcji producenta testu diagnostycznego","categories":["other"],"row_index":116,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of IgG class antibodies against Borrelia","search_en":"Presence of IgG class antibodies against Borrelia Enzyme immunoassay method (ELISA) PB-18 | na podstawie instrukcji producenta testu diagnostycznego","technique_en":"Enzyme immunoassay method (ELISA)","search_zh":"酶联免疫吸附法（ELISA） PB-18 | na podstawie instrukcji producenta testu diagnostycznego","technique_zh":"酶联免疫吸附法（ELISA）"},{"_id":"6a836ff8af14b9c0e7b1ee3c","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Surowica, płyn mózgowo-rdzeniowy E","methodology":"Obecność przeciwciał klasy IgM przeciwko Borrelia","parameters":[],"technique":"Metoda immunoenzymatyczna Western-blot","techniques":["Metoda immunoenzymatyczna Western-blot"],"computed":[],"activity":"Obecność przeciwciał klasy IgM przeciwko Borrelia\nMetoda immunoenzymatyczna Western-blot","reference":"PB-19 | na podstawie instrukcji producenta testu diagnostycznego","norm_bases":["PB-19","na podstawie instrukcji producenta testu diagnostycznego"],"lab_section":"Dział Laboratoryjny/ Oddział Mikrobiologii i Parazytologii; Pracownia Wirusologii i Serologii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniona publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Surowica, płyn mózgowo-rdzeniowy E Obecność przeciwciał klasy IgM przeciwko Borrelia\nMetoda immunoenzymatyczna Western-blot PB-19 | na podstawie instrukcji producenta testu diagnostycznego Surowica, plyn mozgowo-rdzeniowy E Obecnosc przeciwcial klasy IgM przeciwko Borrelia\nMetoda immunoenzymatyczna Western-blot PB-19 | na podstawie instrukcji producenta testu diagnostycznego","categories":["other"],"row_index":117,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of IgM class antibodies against Borrelia","search_en":"Presence of IgM class antibodies against Borrelia PB-19 | na podstawie instrukcji producenta testu diagnostycznego"},{"_id":"6a836ff8af14b9c0e7b1ee3d","lab_id":"69ad52a3de79e566650fb271","country":"PL","accr_number":"AB 492","accr_body":"PCA","test_object":"Surowica, płyn mózgowo-rdzeniowy E","methodology":"Obecność przeciwciał klasy IgG przeciwko Borrelia","parameters":[],"technique":"Metoda immunoenzymatyczna Western-blot","techniques":["Metoda immunoenzymatyczna Western-blot"],"computed":[],"activity":"Obecność przeciwciał klasy IgG przeciwko Borrelia\nMetoda immunoenzymatyczna Western-blot","reference":"PB-19 | na podstawie instrukcji producenta testu diagnostycznego","norm_bases":["PB-19","na podstawie instrukcji producenta testu diagnostycznego"],"lab_section":"Dział Laboratoryjny/ Oddział Mikrobiologii i Parazytologii; Pracownia Wirusologii i Serologii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniona publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Surowica, płyn mózgowo-rdzeniowy E Obecność przeciwciał klasy IgG przeciwko Borrelia\nMetoda immunoenzymatyczna Western-blot PB-19 | na podstawie instrukcji producenta testu diagnostycznego Surowica, plyn mozgowo-rdzeniowy E Obecnosc przeciwcial klasy IgG przeciwko Borrelia\nMetoda immunoenzymatyczna Western-blot PB-19 | na podstawie instrukcji producenta testu diagnostycznego","categories":["other"],"row_index":118,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of IgG class antibodies against Borrelia","search_en":"Presence of IgG class antibodies against Borrelia PB-19 | na podstawie instrukcji producenta testu diagnostycznego"}],"has_pdf":true}