{"lab":{"_id":"69ad52a3de79e566650fb263","accr_number":"AB 484","country":"PL","accr_body":"PCA","address":"ul. Chemików 7, 09-411 Płock","categories":["petro","water","environment","materials","automotive","construction"],"city":"Płock","imported_at":"2026-03-08T10:42:43.265Z","methods_count":668,"name":"ORLEN LABORATORIUM S.A.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_484.pdf"],"scope_summary":"","search_text":"orlen laboratorium s.a. ul. chemików 7, 09-411 płock water pharma electronics other petro food environment materials automotive metrology construction","status":"active","updated_at":"2026-03-08T14:51:19.823Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-09-03T00:42:34.530Z","location":{"type":"Point","coordinates":[19.7065,52.5463]},"email_confidence":"low","email_mx":false,"email_source":"https://www.pca.gov.pl/akredytowane-podmioty/akredytacje-aktywne/laboratoria-badawcze/AB%20484,podmiot.html","needs_review":true,"review_reason":"domena bez MX — zweryfikuj","fields_of_testing":[{"codes":"C/10/P; C/28/P; C/29/P; C/30/P","pl":"Badania chemiczne i pobieranie próbek paliw ciekłych, paliw gazowych, wody, wody do spożycia przez ludzi, ścieków","en":"Chemical tests and sampling of aliquid fuels, gas fuels, water, water for human consumption, sewage"},{"codes":"C/33/P","pl":"Badania chemiczne i pobieranie próbek – środowisko pracy (czynniki szkodliwe - powietrze)","en":"Chemical tests and sampling - working environment (harmful factors - air)"},{"codes":"C/4; C/5; C/9; C/31; C/32; C/36; C/46; C/47; C/48","pl":"Badania chemiczne wyrobów chemicznych, materiałów budowlanych, powietrza, gleby, odpadów, gazów odlotowych, materiałów smarnych, ropy naftowej, innych przetworów naftowych","en":"Chemical tests and sampling of chemical products, building materials, air, soil, waste, waste gases, lubricants, crude oil, other petroluem products"},{"codes":"G/33","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki szkodliwe i uciążliwe – oświetlenie, pole elektromagnetyczne, mikroklimat, drgania, hałas w środowisku pracy)","en":"Tests concerning environmental engineering (environmental and climatic) – working environment (harmful and nuisance factors – lighting, electromagnetic field, microclimate, vibration, noise in working envionment)"},{"codes":"N/10/P; N/28/P; N/29/P; N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek paliw ciekłych, paliw gazowych, wody, wody do spożycia przez ludzi, ścieków","en":"Tests of physical properties and sampling of liquid fuels, gas fuels, water, drinking water, sewage"},{"codes":"N/33/P","pl":"Badania właściwości fizycznych i pobieranie próbek – środowisko pracy (czynniki szkodliwe - powietrze)","en":"Tests of physical properties and sampling - working environment (harmful factors - air)"},{"codes":"N/4; N/5; N/31; N/32; N/46; N/47; N/48","pl":"Badania właściwości fizycznych wyrobów chemicznych, materiałów budowlanych, gleby, osadów, materiałów smarnych, ropy naftowej, innych przetworów naftowych","en":"Tests of physical properties of chemical products, building materials, soil, sediments, lubricants, crude oil, other petroleum products"},{"codes":"Q/10/P","pl":"Badania sensoryczne i pobieranie próbek paliw gazowych","en":"Sensory tests and sampling of gas fuels"},{"codes":"28/P; 29/P","pl":"Pobieranie próbek wody i wody do spożycia do badań mikrobiologicznych","en":"Sampling of water and water for human consumption for microbiological testing"}],"issue":{"no":"52","date":"30.07.2026"},"parse_date":"2026-09-03T00:42:34.530Z","parse_source":"agent-claude-code","map_coord":[52.586402,19.653731],"map_geo":"nominatim-street","lab_locations":[{"code":null,"name":"ORLEN LABORATORIUM S.A.","street":"ul. Chemików 7","postal_code":"09-411","city":"Płock","is_hq":true,"address":"ul. Chemików 7, 09-411 Płock","site":"09-411|chemików7"},{"code":null,"name":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","street":"ul. Chemików 7","postal_code":"09-411","city":"Płock","is_hq":false,"address":"ul. Chemików 7, 09-411 Płock","site":"09-411|chemików7"},{"code":null,"name":"Pracownia Paliw i Aromatów PP1","street":"ul. Chemików 7","postal_code":"09-411","city":"Płock","is_hq":false,"address":"ul. Chemików 7, 09-411 Płock","site":"09-411|chemików7"},{"code":null,"name":"Pracownia Przerobu Ropy PP2","street":"ul. Chemików 7","postal_code":"09-411","city":"Płock","is_hq":false,"address":"ul. Chemików 7, 09-411 Płock","site":"09-411|chemików7"},{"code":null,"name":"Pracownia Środowiska Pracy PP8","street":"ul. Chemików 7","postal_code":"09-411","city":"Płock","is_hq":false,"address":"ul. Chemików 7, 09-411 Płock","site":"09-411|chemików7"},{"code":null,"name":"Pracownia Chromatografii PP3","street":"ul. Chemików 7","postal_code":"09-411","city":"Płock","is_hq":false,"address":"ul. Chemików 7, 09-411 Płock","site":"09-411|chemików7"},{"code":null,"name":"Zespół Logistyki Płock LL/P","street":"ul. Chemików 7","postal_code":"09-411","city":"Płock","is_hq":false,"address":"ul. Chemików 7, 09-411 Płock","site":"09-411|chemików7"},{"code":null,"name":"Zespół Logistyki Włocławek LL/W","street":"ul. Toruńska 222","postal_code":"87-800","city":"Włocławek","is_hq":false,"address":"ul. Toruńska 222, 87-800 Włocławek","site":"87-800|toruńska222"},{"code":null,"name":"Pracownia PTA TT5","street":"ul. Krzywa Góra 13/15/17","postal_code":"87-800","city":"Włocławek","is_hq":false,"address":"ul. Krzywa Góra 13/15/17, 87-800 Włocławek","site":"87-800|krzywagóra13/15/17"},{"code":null,"name":"Punkt Obsługi Laboratoryjnej we Wrocławiu PP7/5","street":"ul. Swojczycka 44","postal_code":"51-501","city":"Wrocław","is_hq":false,"address":"ul. Swojczycka 44, 51-501 Wrocław","site":"51-501|swojczycka44"},{"code":null,"name":"Punkt Obsługi Laboratoryjnej we Wrocławiu PP7/5 (Działalność techniczna)","street":"ul. Swojczycka 43","postal_code":"51-501","city":"Wrocław","is_hq":false,"address":"ul. Swojczycka 43, 51-501 Wrocław","site":"51-501|swojczycka43"},{"code":null,"name":"Pracownia Produktów Rafineryjnych w Trzebini PP6","street":"ul. Fabryczna 22","postal_code":"32-540","city":"Trzebinia","is_hq":false,"address":"ul. Fabryczna 22, 32-540 Trzebinia","site":"32-540|fabryczna22"},{"code":null,"name":"Pracownia Produktów Naftowych w Jedliczu PP5","street":"ul. Trzecieskiego 14","postal_code":"38-460","city":"Jedlicze","is_hq":false,"address":"ul. Trzecieskiego 14, 38-460 Jedlicze","site":"38-460|trzecieskiego14"},{"code":null,"name":"Punkt Obsługi Laboratoryjnej w Ostrowie Wielkopolskim PP7/3","street":"ul. Węglowa 1","postal_code":"63-400","city":"Ostrów Wielkopolski","is_hq":false,"address":"ul. Węglowa 1, 63-400 Ostrów Wielkopolski","site":"63-400|węglowa1"},{"code":null,"name":"Punkt Obsługi Laboratoryjnej w Lublinie PP7/1","street":"ul. Zemborzycka 116 B","postal_code":"20-445","city":"Lublin","is_hq":false,"address":"ul. Zemborzycka 116 B, 20-445 Lublin","site":"20-445|zemborzycka116b"},{"code":null,"name":"Punkt Obsługi Laboratoryjnej w Olsztynie PP7/2","street":"ul. Gutkowo 54","postal_code":"11-041","city":"Olsztyn","is_hq":false,"address":"ul. Gutkowo 54, 11-041 Olsztyn","site":"11-041|gutkowo54"},{"code":null,"name":"Punkt Obsługi Laboratoryjnej w Warszawie PP7/4","street":"ul. Estrady 8","postal_code":"05-080","city":"Izabelin","is_hq":false,"address":"ul. Estrady 8, 05-080 Izabelin","site":"05-080|estrady8"},{"code":null,"name":"Pracownia Nawozów i Środowiska Naturalnego TT1","street":"ul. Toruńska 222","postal_code":"87-800","city":"Włocławek","is_hq":false,"address":"ul. Toruńska 222, 87-800 Włocławek","site":"87-800|toruńska222"}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/9/2/e7f83c590f165a68ce7c102eb5e55513/AB%20484.pdf","has_en":true,"category_counts":{"petro":402,"water":158,"environment":100,"materials":61,"other":41,"automotive":22,"construction":8,"microbiology":1},"category_scores":{"petro":203.79,"water":31.48,"environment":12.61,"materials":4.69,"other":2.12,"automotive":0.61,"construction":0.08,"microbiology":0},"has_zh":true},"methods":[{"_id":"6a98c27b2047650df5dfb545","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie: węgla ogólnego (TC), ogólnego węgla organicznego (TOC)","parameters":[{"name":"Zakres","range":"(0,30 – 1000) mg/l"},{"name":"Stężenie ogólnego węgla nieorganicznego (TIC)"},{"name":"Zakres","range":"(1,00 – 10,0) mg/l"}],"technique":"Metoda spektrometrii w zakresie podczerwieni IR","techniques":["Metoda spektrometrii w zakresie podczerwieni IR"],"computed":[],"activity":"Stężenie: węgla ogólnego (TC), ogólnego węgla organicznego (TOC)\nZakres:\nZakres (0,30 – 1000) mg/l\nStężenie ogólnego węgla nieorganicznego (TIC)\nZakres (1,00 – 10,0) mg/l\nMetoda spektrometrii w zakresie podczerwieni IR","reference":"PN-EN 1484:1999","norm_bases":["PN-EN 1484:1999"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie: węgla ogólnego (TC), ogólnego węgla organicznego (TOC)\nZakres:\nZakres (0,30 – 1000) mg/l\nStężenie ogólnego węgla nieorganicznego (TIC)\nZakres (1,00 – 10,0) mg/l\nMetoda spektrometrii w zakresie podczerwieni IR PN-EN 1484:1999 Woda, scieki Stezenie: wegla ogolnego (TC), ogolnego wegla organicznego (TOC)\nZakres:\nZakres (0,30 – 1000) mg/l\nStezenie ogolnego wegla nieorganicznego (TIC)\nZakres (1,00 – 10,0) mg/l\nMetoda spektrometrii w zakresie podczerwieni IR PN-EN 1484:1999","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb546","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"10,0 μS/cm – 100 mS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres 10,0 μS/cm – 100 mS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Przewodność elektryczna właściwa\nZakres 10,0 μS/cm – 100 mS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, scieki Przewodnosc elektryczna wlasciwa\nZakres 10,0 μS/cm – 100 mS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb547","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie siarczanów (VI)","parameters":[{"name":"Zakres","range":"(10 – 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie siarczanów (VI)\nZakres (10 – 1000) mg/l\nMetoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie siarczanów (VI)\nZakres (10 – 1000) mg/l\nMetoda wagowa PN-ISO 9280:2002 Woda, scieki Stezenie siarczanow (VI)\nZakres (10 – 1000) mg/l\nMetoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb548","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Indeks fenolowy","parameters":[{"name":"Zakres","range":"(0,010 – 10) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Indeks fenolowy\nZakres (0,010 – 10) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6439:1994","norm_bases":["PN-ISO 6439:1994"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Indeks fenolowy\nZakres (0,010 – 10) mg/l\nMetoda spektrofotometryczna PN-ISO 6439:1994 Woda, scieki Indeks fenolowy\nZakres (0,010 – 10) mg/l\nMetoda spektrofotometryczna PN-ISO 6439:1994","categories":["water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb549","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu BZT5","parameters":[{"name":"Zakres","range":"(2 – 6000) mg O2/l"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu BZT5\nZakres (2 – 6000) mg O2/l\nMetoda optyczna","reference":"PN-EN ISO 5815-1 :2019-12","norm_bases":["PN-EN ISO 5815-1 :2019-12"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu BZT5\nZakres (2 – 6000) mg O2/l\nMetoda optyczna PN-EN ISO 5815-1 :2019-12 Woda, scieki Biochemiczne zapotrzebowanie tlenu BZT5\nZakres (2 – 6000) mg O2/l\nMetoda optyczna PN-EN ISO 5815-1 :2019-12","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb54a","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie chromu (VI)","parameters":[{"name":"Zakres","range":"(2 – 20) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chromu (VI)\nZakres (2 – 20) μg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 18412:2007","norm_bases":["PN-EN ISO 18412:2007"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie chromu (VI)\nZakres (2 – 20) μg/l\nMetoda spektrofotometryczna PN-EN ISO 18412:2007 Woda Stezenie chromu (VI)\nZakres (2 – 20) μg/l\nMetoda spektrofotometryczna PN-EN ISO 18412:2007","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb54b","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie fosforu","parameters":[{"name":"Zakres","range":"(0,01 – 50) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu\nZakres (0,01 – 50) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010","norm_bases":["PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie fosforu\nZakres (0,01 – 50) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 Scieki Stezenie fosforu\nZakres (0,01 – 50) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb54c","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(10 – 5 000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (10 – 5 000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie chlorków\nZakres (10 – 5 000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Scieki Stezenie chlorkow\nZakres (10 – 5 000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb54d","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,040 – 5,00) mg/l"},{"name":"Stężenie amoniaku (jonu amonowego) Z obliczeń"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres:\nZakres (0,040 – 5,00) mg/l\nStężenie amoniaku (jonu amonowego) Z obliczeń\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu amonowego\nZakres:\nZakres (0,040 – 5,00) mg/l\nStężenie amoniaku (jonu amonowego) Z obliczeń\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Scieki Stezenie azotu amonowego\nZakres:\nZakres (0,040 – 5,00) mg/l\nStezenie amoniaku (jonu amonowego) Z obliczen\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb54e","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(1,0 – 2000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (1,0 – 2000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Zawiesiny ogólne\nZakres (1,0 – 2000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Scieki Zawiesiny ogolne\nZakres (1,0 – 2000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb54f","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(1,0 – 100) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (1,0 – 100) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu Kjeldahla\nZakres (1,0 – 100) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Scieki Stezenie azotu Kjeldahla\nZakres (1,0 – 100) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb550","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"Chemiczne zapotrzebowanie tlenu (ChZT)","parameters":[{"name":"Zakres","range":"(10,0 – 10000) mg O2/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu (ChZT)\nZakres (10,0 – 10000) mg O2/l\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Chemiczne zapotrzebowanie tlenu (ChZT)\nZakres (10,0 – 10000) mg O2/l\nMetoda spektrofotometryczna PN-ISO 15705:2005 Scieki Chemiczne zapotrzebowanie tlenu (ChZT)\nZakres (10,0 – 10000) mg O2/l\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb551","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Scieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb552","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu ogólnego (suma azotu Kjeldahla, azotu azotanowego i azotynowego) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu ogólnego (suma azotu Kjeldahla, azotu azotanowego i azotynowego) (z obliczeń)","reference":"Metoda nr 047 Wydanie 5 z dnia 19.11.2019","norm_bases":["Metoda nr 047 Wydanie 5 z dnia 19.11.2019"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu ogólnego (suma azotu Kjeldahla, azotu azotanowego i azotynowego) (z obliczeń) Metoda nr 047 Wydanie 5 z dnia 19.11.2019 Scieki Stezenie azotu ogolnego (suma azotu Kjeldahla, azotu azotanowego i azotynowego) (z obliczen) Metoda nr 047 Wydanie 5 z dnia 19.11.2019","categories":["water"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb553","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie chromu +6","parameters":[{"name":"Zakres","range":"(0,01 – 1,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chromu +6\nZakres (0,01 – 1,00) mg/l\nMetoda spektrofotometryczna","reference":"PN-C-04604-08:1977","norm_bases":["PN-C-04604-08:1977"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie chromu +6\nZakres (0,01 – 1,00) mg/l\nMetoda spektrofotometryczna PN-C-04604-08:1977 Scieki Stezenie chromu +6\nZakres (0,01 – 1,00) mg/l\nMetoda spektrofotometryczna PN-C-04604-08:1977","categories":["water"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb554","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,010 – 10,0) mg/l"},{"name":"Stężenie azotynów (z obliczeń)"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres:\nZakres (0,010 – 10,0) mg/l\nStężenie azotynów (z obliczeń)\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu azotynowego\nZakres:\nZakres (0,010 – 10,0) mg/l\nStężenie azotynów (z obliczeń)\nMetoda spektrofotometryczna PN-EN 26777:1999 Scieki Stezenie azotu azotynowego\nZakres:\nZakres (0,010 – 10,0) mg/l\nStezenie azotynow (z obliczen)\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb555","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie substancji organicznych ekstrahujących się eterem naftowym","parameters":[{"name":"Zakres","range":"(2,0 – 420) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie substancji organicznych ekstrahujących się eterem naftowym\nZakres (2,0 – 420) mg/l\nMetoda wagowa","reference":"Metoda nr 115 wydanie 4 z dnia 18.12.2020","norm_bases":["Metoda nr 115 wydanie 4 z dnia 18.12.2020"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie substancji organicznych ekstrahujących się eterem naftowym\nZakres (2,0 – 420) mg/l\nMetoda wagowa Metoda nr 115 wydanie 4 z dnia 18.12.2020 Scieki Stezenie substancji organicznych ekstrahujacych sie eterem naftowym\nZakres (2,0 – 420) mg/l\nMetoda wagowa Metoda nr 115 wydanie 4 z dnia 18.12.2020","categories":["water"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb556","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"Sucha pozostałość, pozostałość po prażeniu oraz substancje rozpuszczone","parameters":[{"name":"Zakres","range":"(10 – 10000) mg/l"},{"name":"Straty przy prażeniu (z obliczeń)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha pozostałość, pozostałość po prażeniu oraz substancje rozpuszczone\nZakres:\nZakres (10 – 10000) mg/l\nStraty przy prażeniu (z obliczeń)\nMetoda wagowa","reference":"Metoda nr 124 wydanie 2 z dnia 03.06.2020 r.","norm_bases":["Metoda nr 124 wydanie 2 z dnia 03.06.2020 r."],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Sucha pozostałość, pozostałość po prażeniu oraz substancje rozpuszczone\nZakres:\nZakres (10 – 10000) mg/l\nStraty przy prażeniu (z obliczeń)\nMetoda wagowa Metoda nr 124 wydanie 2 z dnia 03.06.2020 r. Scieki Sucha pozostalosc, pozostalosc po prazeniu oraz substancje rozpuszczone\nZakres:\nZakres (10 – 10000) mg/l\nStraty przy prazeniu (z obliczen)\nMetoda wagowa Metoda nr 124 wydanie 2 z dnia 03.06.2020 r.","categories":["water"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb557","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu azotanowego","parameters":[{"name":"Zakres","range":"(0,010 – 30,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotanowego\nZakres (0,010 – 30,0) mg/l\nMetoda spektrofotometryczna","reference":"Metoda nr 125 wydanie 2 z dnia 16.07.2020 r.","norm_bases":["Metoda nr 125 wydanie 2 z dnia 16.07.2020 r."],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu azotanowego\nZakres (0,010 – 30,0) mg/l\nMetoda spektrofotometryczna Metoda nr 125 wydanie 2 z dnia 16.07.2020 r. Scieki Stezenie azotu azotanowego\nZakres (0,010 – 30,0) mg/l\nMetoda spektrofotometryczna Metoda nr 125 wydanie 2 z dnia 16.07.2020 r.","categories":["water"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb558","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie siarczków","parameters":[{"name":"Zakres","range":"(0,10 – 1,50) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie siarczków\nZakres (0,10 – 1,50) mg/l\nMetoda spektrofotometryczna","reference":"Metoda nr 179 wydanie 3 z dnia 13.12.2023 r.","norm_bases":["Metoda nr 179 wydanie 3 z dnia 13.12.2023 r."],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie siarczków\nZakres (0,10 – 1,50) mg/l\nMetoda spektrofotometryczna Metoda nr 179 wydanie 3 z dnia 13.12.2023 r. Scieki Stezenie siarczkow\nZakres (0,10 – 1,50) mg/l\nMetoda spektrofotometryczna Metoda nr 179 wydanie 3 z dnia 13.12.2023 r.","categories":["water"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb559","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(1,0 – 20) mg/l"},{"name":"Stężenie amoniaku (jonu amonowego) (z obliczeń)"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres:\nZakres (1,0 – 20) mg/l\nStężenie amoniaku (jonu amonowego) (z obliczeń)\nMetoda miareczkowa","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu amonowego\nZakres:\nZakres (1,0 – 20) mg/l\nStężenie amoniaku (jonu amonowego) (z obliczeń)\nMetoda miareczkowa PN-ISO 5664:2002 Scieki Stezenie azotu amonowego\nZakres:\nZakres (1,0 – 20) mg/l\nStezenie amoniaku (jonu amonowego) (z obliczen)\nMetoda miareczkowa PN-ISO 5664:2002","categories":["water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb55a","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Zawartość substancji ekstrahujących się dichlorometanem","parameters":[{"name":"Zakres","range":"(0,10 – 20,0) %m/m"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość substancji ekstrahujących się dichlorometanem\nZakres (0,10 – 20,0) %m/m\nMetoda wagowa","reference":"Metoda 106 Wydanie 3 z dnia 21.12.2020","norm_bases":["Metoda 106 Wydanie 3 z dnia 21.12.2020"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Zawartość substancji ekstrahujących się dichlorometanem\nZakres (0,10 – 20,0) %m/m\nMetoda wagowa Metoda 106 Wydanie 3 z dnia 21.12.2020 Osady sciekowe Zawartosc substancji ekstrahujacych sie dichlorometanem\nZakres (0,10 – 20,0) %m/m\nMetoda wagowa Metoda 106 Wydanie 3 z dnia 21.12.2020","categories":["water"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb55b","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Sucha pozostałość","parameters":[{"name":"Zakres","range":"(0,8 – 48,0) %"},{"name":"Zawartość wody (z obliczeń)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha pozostałość\nZakres:\nZakres (0,8 – 48,0) %\nZawartość wody (z obliczeń)\nMetoda wagowa","reference":"PN-EN 15934:2013-02 Metoda A","norm_bases":["PN-EN 15934:2013-02 Metoda A"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Sucha pozostałość\nZakres:\nZakres (0,8 – 48,0) %\nZawartość wody (z obliczeń)\nMetoda wagowa PN-EN 15934:2013-02 Metoda A Osady sciekowe Sucha pozostalosc\nZakres:\nZakres (0,8 – 48,0) %\nZawartosc wody (z obliczen)\nMetoda wagowa PN-EN 15934:2013-02 Metoda A","categories":["water"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb55c","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Straty przy prażeniu suchej masy","parameters":[{"name":"Zakres","range":"(7,0 – 85,0)%"},{"name":"Pozostałość po prażeniu suchej masy (z obliczeń)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Straty przy prażeniu suchej masy\nZakres:\nZakres (7,0 – 85,0)%\nPozostałość po prażeniu suchej masy (z obliczeń)\nMetoda wagowa","reference":"PN-EN 15935:2022-01","norm_bases":["PN-EN 15935:2022-01"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Straty przy prażeniu suchej masy\nZakres:\nZakres (7,0 – 85,0)%\nPozostałość po prażeniu suchej masy (z obliczeń)\nMetoda wagowa PN-EN 15935:2022-01 Osady sciekowe Straty przy prazeniu suchej masy\nZakres:\nZakres (7,0 – 85,0)%\nPozostalosc po prazeniu suchej masy (z obliczen)\nMetoda wagowa PN-EN 15935:2022-01","categories":["water"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb55d","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiał budowlany: gips","methodology":"Zawartość wilgoci","parameters":[{"name":"Zakres","range":"(5,0 – 13,0) %"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Zawartość wilgoci\nZakres (5,0 – 13,0) %\nMetoda grawimetryczna","reference":"VGB-M 701 e:2008 p. 1.2","norm_bases":["VGB-M 701 e:2008 p. 1.2"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiał budowlany: gips Zawartość wilgoci\nZakres (5,0 – 13,0) %\nMetoda grawimetryczna VGB-M 701 e:2008 p. 1.2 Material budowlany: gips Zawartosc wilgoci\nZakres (5,0 – 13,0) %\nMetoda grawimetryczna VGB-M 701 e:2008 p. 1.2","categories":["materials","construction"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb55e","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiał budowlany: gips","methodology":"Stopień czystości (CaSO4x2H2O)","parameters":[{"name":"Zakres","range":"(96,0 – 99,0) %"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stopień czystości (CaSO4x2H2O)\nZakres (96,0 – 99,0) %\nMetoda grawimetryczna","reference":"VGB-M 701 e:2008 p. 2.1","norm_bases":["VGB-M 701 e:2008 p. 2.1"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiał budowlany: gips Stopień czystości (CaSO4x2H2O)\nZakres (96,0 – 99,0) %\nMetoda grawimetryczna VGB-M 701 e:2008 p. 2.1 Material budowlany: gips Stopien czystosci (CaSO4x2H2O)\nZakres (96,0 – 99,0) %\nMetoda grawimetryczna VGB-M 701 e:2008 p. 2.1","categories":["materials","construction"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb55f","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiał budowlany: gips","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 – 9,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 – 9,0\nMetoda potencjometryczna","reference":"VGB-M 701 e:2008 p. 4","norm_bases":["VGB-M 701 e:2008 p. 4"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiał budowlany: gips pH\nZakres 4,0 – 9,0\nMetoda potencjometryczna VGB-M 701 e:2008 p. 4 Material budowlany: gips pH\nZakres 4,0 – 9,0\nMetoda potencjometryczna VGB-M 701 e:2008 p. 4","categories":["materials","construction"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb560","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiał budowlany: gips","methodology":"Stopień białości","parameters":[{"name":"Zakres","range":"(35,0 – 78,0) % Ry"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stopień białości\nZakres (35,0 – 78,0) % Ry\nMetoda spektrofotometryczna","reference":"VGB-M 701 e:2008 p. 5","norm_bases":["VGB-M 701 e:2008 p. 5"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiał budowlany: gips Stopień białości\nZakres (35,0 – 78,0) % Ry\nMetoda spektrofotometryczna VGB-M 701 e:2008 p. 5 Material budowlany: gips Stopien bialosci\nZakres (35,0 – 78,0) % Ry\nMetoda spektrofotometryczna VGB-M 701 e:2008 p. 5","categories":["materials","construction"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb561","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiał budowlany: gips","methodology":"Rozmiar cząstek – analiza granulometryczna >32 μm","parameters":[{"name":"Zakres","range":"(48,0 – 86,0) %"}],"technique":"Metoda dyfrakcji laserowej","techniques":["Metoda dyfrakcji laserowej"],"computed":[],"activity":"Rozmiar cząstek – analiza granulometryczna >32 μm\nZakres (48,0 – 86,0) %\nMetoda dyfrakcji laserowej","reference":"Metoda nr 184 wydanie 2 z dnia 13.12.2023","norm_bases":["Metoda nr 184 wydanie 2 z dnia 13.12.2023"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiał budowlany: gips Rozmiar cząstek – analiza granulometryczna >32 μm\nZakres (48,0 – 86,0) %\nMetoda dyfrakcji laserowej Metoda nr 184 wydanie 2 z dnia 13.12.2023 Material budowlany: gips Rozmiar czastek – analiza granulometryczna >32 μm\nZakres (48,0 – 86,0) %\nMetoda dyfrakcji laserowej Metoda nr 184 wydanie 2 z dnia 13.12.2023","categories":["materials","construction"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb562","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiał budowlany: gips","methodology":"Oznaczanie węglanów jako CaCO3","parameters":[{"name":"Zakres","range":"(0,15 – 1,15) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Oznaczanie węglanów jako CaCO3\nZakres (0,15 – 1,15) %\nMetoda miareczkowa","reference":"VGB-M 701 e:2008 p. 8.12","norm_bases":["VGB-M 701 e:2008 p. 8.12"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiał budowlany: gips Oznaczanie węglanów jako CaCO3\nZakres (0,15 – 1,15) %\nMetoda miareczkowa VGB-M 701 e:2008 p. 8.12 Material budowlany: gips Oznaczanie weglanow jako CaCO3\nZakres (0,15 – 1,15) %\nMetoda miareczkowa VGB-M 701 e:2008 p. 8.12","categories":["materials","construction"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb563","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiał budowlany: gips","methodology":"Zawartość chlorków Cl-","parameters":[{"name":"Zakres","range":"(24 – 130) mg/kg"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość chlorków Cl-\nZakres (24 – 130) mg/kg\nMetoda miareczkowa","reference":"VGB-M 701 e:2008 p. 8.8.3","norm_bases":["VGB-M 701 e:2008 p. 8.8.3"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiał budowlany: gips Zawartość chlorków Cl-\nZakres (24 – 130) mg/kg\nMetoda miareczkowa VGB-M 701 e:2008 p. 8.8.3 Material budowlany: gips Zawartosc chlorkow Cl-\nZakres (24 – 130) mg/kg\nMetoda miareczkowa VGB-M 701 e:2008 p. 8.8.3","categories":["materials","construction"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb564","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: gaz ziemny, gaz suchy, gazy wodorowe, gazy wysokociśnieniowe, gazy niskociśnieniowe","methodology":"Zawartość siarkowodoru","parameters":[{"name":"Zakres","range":"(0,0002 – 0,0650) %(v/v)"},{"name":"Zakres","range":"(0,0650 – 93) %(v/v)"}],"technique":"Metoda miareczkowa; Metoda miareczkowa","techniques":["Metoda miareczkowa","Metoda miareczkowa"],"computed":[],"activity":"Zawartość siarkowodoru\nZakres:\nZakres (0,0002 – 0,0650) %(v/v)\nZakres (0,0650 – 93) %(v/v)\nMetoda miareczkowa; Metoda miareczkowa","reference":"Metoda 041 wydanie 6 z dnia 14.11.2024","norm_bases":["Metoda 041 wydanie 6 z dnia 14.11.2024"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: gaz ziemny, gaz suchy, gazy wodorowe, gazy wysokociśnieniowe, gazy niskociśnieniowe Zawartość siarkowodoru\nZakres:\nZakres (0,0002 – 0,0650) %(v/v)\nZakres (0,0650 – 93) %(v/v)\nMetoda miareczkowa; Metoda miareczkowa Metoda 041 wydanie 6 z dnia 14.11.2024 Paliwa gazowe: gaz ziemny, gaz suchy, gazy wodorowe, gazy wysokocisnieniowe, gazy niskocisnieniowe Zawartosc siarkowodoru\nZakres:\nZakres (0,0002 – 0,0650) %(v/v)\nZakres (0,0650 – 93) %(v/v)\nMetoda miareczkowa; Metoda miareczkowa Metoda 041 wydanie 6 z dnia 14.11.2024","categories":["petro"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb565","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Liczba jodowa","parameters":[{"name":"Zakres","range":"(105 – 120) g jodu/100g FAME"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Liczba jodowa\nZakres (105 – 120) g jodu/100g FAME\nMetoda miareczkowa","reference":"PN-EN 14111:2022-11","norm_bases":["PN-EN 14111:2022-11"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Liczba jodowa\nZakres (105 – 120) g jodu/100g FAME\nMetoda miareczkowa PN-EN 14111:2022-11 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Liczba jodowa\nZakres (105 – 120) g jodu/100g FAME\nMetoda miareczkowa PN-EN 14111:2022-11","categories":["petro"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb566","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: olej napędowy z FAME, estry metylowe kwasów tłuszczowych (FAME)","methodology":"Liczba kwasowa","parameters":[{"name":"Zakres","range":"(0,10 – 1,00) mg KOH/g"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Liczba kwasowa\nZakres (0,10 – 1,00) mg KOH/g\nMetoda miareczkowa","reference":"PN-EN 14104:2021-06","norm_bases":["PN-EN 14104:2021-06"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: olej napędowy z FAME, estry metylowe kwasów tłuszczowych (FAME) Liczba kwasowa\nZakres (0,10 – 1,00) mg KOH/g\nMetoda miareczkowa PN-EN 14104:2021-06 Paliwa ciekle: biopaliwa ciekle: olej napedowy z FAME, estry metylowe kwasow tluszczowych (FAME) Liczba kwasowa\nZakres (0,10 – 1,00) mg KOH/g\nMetoda miareczkowa PN-EN 14104:2021-06","categories":["petro"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb567","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: bioetanol","methodology":"Sucha pozostałość","parameters":[{"name":"Zakres","range":"(5 – 25) mg/100ml"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha pozostałość\nZakres (5 – 25) mg/100ml\nMetoda wagowa","reference":"PN-EN 15691:2023-11","norm_bases":["PN-EN 15691:2023-11"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: bioetanol Sucha pozostałość\nZakres (5 – 25) mg/100ml\nMetoda wagowa PN-EN 15691:2023-11 Paliwa ciekle: biopaliwa ciekle: bioetanol Sucha pozostalosc\nZakres (5 – 25) mg/100ml\nMetoda wagowa PN-EN 15691:2023-11","categories":["petro"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb568","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: bioetanol","methodology":"Całkowita kwasowość","parameters":[{"name":"Zakres","range":"(0,003 – 0,013) %(m/m)"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Całkowita kwasowość\nZakres (0,003 – 0,013) %(m/m)\nMetoda miareczkowa","reference":"PN-EN 15491:2025-08","norm_bases":["PN-EN 15491:2025-08"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: bioetanol Całkowita kwasowość\nZakres (0,003 – 0,013) %(m/m)\nMetoda miareczkowa PN-EN 15491:2025-08 Paliwa ciekle: biopaliwa ciekle: bioetanol Calkowita kwasowosc\nZakres (0,003 – 0,013) %(m/m)\nMetoda miareczkowa PN-EN 15491:2025-08","categories":["petro"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb569","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: bioetanol","methodology":"Zawartość wody","parameters":[{"name":"Zakres","range":"(0,073 – 0,500) %(m/m)"}],"technique":"Metoda miareczkowania kulometrycznego","techniques":["Metoda miareczkowania kulometrycznego"],"computed":[],"activity":"Zawartość wody\nZakres (0,073 – 0,500) %(m/m)\nMetoda miareczkowania kulometrycznego","reference":"PN-EN 15489:2009","norm_bases":["PN-EN 15489:2009"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: bioetanol Zawartość wody\nZakres (0,073 – 0,500) %(m/m)\nMetoda miareczkowania kulometrycznego PN-EN 15489:2009 Paliwa ciekle: biopaliwa ciekle: bioetanol Zawartosc wody\nZakres (0,073 – 0,500) %(m/m)\nMetoda miareczkowania kulometrycznego PN-EN 15489:2009","categories":["petro","water"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb56a","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: bioetanol","methodology":"Zawartość fosforu","parameters":[{"name":"Zakres","range":"(0,15 – 1,5) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość fosforu\nZakres (0,15 – 1,5) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 15487:2009","norm_bases":["PN-EN 15487:2009"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: bioetanol Zawartość fosforu\nZakres (0,15 – 1,5) mg/l\nMetoda spektrofotometryczna PN-EN 15487:2009 Paliwa ciekle: biopaliwa ciekle: bioetanol Zawartosc fosforu\nZakres (0,15 – 1,5) mg/l\nMetoda spektrofotometryczna PN-EN 15487:2009","categories":["petro"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb56b","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: bioetanol","methodology":"Zawartość chlorków nieorganicznych","parameters":[{"name":"Zakres","range":"(1,0 – 20,0) mg/kg"}],"technique":"Metoda chromatografii jonowej z detektorem konduktometrycznym (IC-CD)","techniques":["Metoda chromatografii jonowej z detektorem konduktometrycznym (IC-CD)"],"computed":[],"activity":"Zawartość chlorków nieorganicznych\nZakres (1,0 – 20,0) mg/kg\nMetoda chromatografii jonowej z detektorem konduktometrycznym (IC-CD)","reference":"PN-EN 15492:2012","norm_bases":["PN-EN 15492:2012"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: bioetanol Zawartość chlorków nieorganicznych\nZakres (1,0 – 20,0) mg/kg\nMetoda chromatografii jonowej z detektorem konduktometrycznym (IC-CD) PN-EN 15492:2012 Paliwa ciekle: biopaliwa ciekle: bioetanol Zawartosc chlorkow nieorganicznych\nZakres (1,0 – 20,0) mg/kg\nMetoda chromatografii jonowej z detektorem konduktometrycznym (IC-CD) PN-EN 15492:2012","categories":["petro"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb56c","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa, Inne przetwory naftowe: destylaty naftowe","methodology":"Prężność par nasyconych powietrzem","parameters":[{"name":"Zakres","range":"(15,5 – 106,0) kPa"}],"technique":"Metoda mini Reid","techniques":["Metoda mini Reid"],"computed":[],"activity":"Prężność par nasyconych powietrzem\nZakres (15,5 – 106,0) kPa\nMetoda mini Reid","reference":"PN-EN 13016-1:2024-11","norm_bases":["PN-EN 13016-1:2024-11"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa, Inne przetwory naftowe: destylaty naftowe Prężność par nasyconych powietrzem\nZakres (15,5 – 106,0) kPa\nMetoda mini Reid PN-EN 13016-1:2024-11 Paliwa ciekle: benzyna bezolowiowa, Inne przetwory naftowe: destylaty naftowe Preznosc par nasyconych powietrzem\nZakres (15,5 – 106,0) kPa\nMetoda mini Reid PN-EN 13016-1:2024-11","categories":["petro","environment"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb56d","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa, Inne przetwory naftowe: destylaty naftowe","methodology":"Skład frakcyjny","parameters":[{"name":"Zakres","range":"(30,0 – 360,0) 0C"}],"technique":"Metoda destylacyjna","techniques":["Metoda destylacyjna"],"computed":[],"activity":"Skład frakcyjny\nZakres (30,0 – 360,0) 0C\nMetoda destylacyjna","reference":"PN-EN ISO 3405:2019-05 z wyłączeniem pkt. 9","norm_bases":["PN-EN ISO 3405:2019-05 z wyłączeniem pkt. 9"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa, Inne przetwory naftowe: destylaty naftowe Skład frakcyjny\nZakres (30,0 – 360,0) 0C\nMetoda destylacyjna PN-EN ISO 3405:2019-05 z wyłączeniem pkt. 9 Paliwa ciekle: benzyna bezolowiowa, Inne przetwory naftowe: destylaty naftowe Sklad frakcyjny\nZakres (30,0 – 360,0) 0C\nMetoda destylacyjna PN-EN ISO 3405:2019-05 z wylaczeniem pkt. 9","categories":["petro"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb56e","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa, benzyna lotnicza","methodology":"Zawartość ołowiu","parameters":[{"name":"Zakres","range":"(2,5 – 6,0) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Zawartość ołowiu\nZakres (2,5 – 6,0) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-EN 237:2007","norm_bases":["PN-EN 237:2007"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa, benzyna lotnicza Zawartość ołowiu\nZakres (2,5 – 6,0) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN 237:2007 Paliwa ciekle: benzyna bezolowiowa, benzyna lotnicza Zawartosc olowiu\nZakres (2,5 – 6,0) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN 237:2007","categories":["petro"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb56f","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa, Inne przetwory naftowe: frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30°C - 250°C","methodology":"Liczba oktanowa LOB","parameters":[{"name":"Zakres","range":"(70 – 115)"}],"technique":"Metoda silnikowa","techniques":["Metoda silnikowa"],"computed":[],"activity":"Liczba oktanowa LOB\nZakres (70 – 115)\nMetoda silnikowa","reference":"PN-EN ISO 5164 :2014-08","norm_bases":["PN-EN ISO 5164 :2014-08"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa, Inne przetwory naftowe: frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30°C - 250°C Liczba oktanowa LOB\nZakres (70 – 115)\nMetoda silnikowa PN-EN ISO 5164 :2014-08 Paliwa ciekle: benzyna bezolowiowa, Inne przetwory naftowe: frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30°C - 250°C Liczba oktanowa LOB\nZakres (70 – 115)\nMetoda silnikowa PN-EN ISO 5164 :2014-08","categories":["petro"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb570","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa, Inne przetwory naftowe: frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30°C - 250°C","methodology":"Liczba oktanowa LOM","parameters":[{"name":"Zakres","range":"(70 – 107)"}],"technique":"Metoda silnikowa","techniques":["Metoda silnikowa"],"computed":[],"activity":"Liczba oktanowa LOM\nZakres (70 – 107)\nMetoda silnikowa","reference":"PN-EN ISO 5163 :2014-08","norm_bases":["PN-EN ISO 5163 :2014-08"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa, Inne przetwory naftowe: frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30°C - 250°C Liczba oktanowa LOM\nZakres (70 – 107)\nMetoda silnikowa PN-EN ISO 5163 :2014-08 Paliwa ciekle: benzyna bezolowiowa, Inne przetwory naftowe: frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30°C - 250°C Liczba oktanowa LOM\nZakres (70 – 107)\nMetoda silnikowa PN-EN ISO 5163 :2014-08","categories":["petro"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb571","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa, Inne przetwory naftowe: frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30°C - 250°C","methodology":"Stabilność oksydacyjna","parameters":[{"name":"Zakres","range":"(60 – 700) minut"}],"technique":"Metoda okresu indukcyjnego","techniques":["Metoda okresu indukcyjnego"],"computed":[],"activity":"Stabilność oksydacyjna\nZakres (60 – 700) minut\nMetoda okresu indukcyjnego","reference":"PN-EN ISO 7536:2011","norm_bases":["PN-EN ISO 7536:2011"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa, Inne przetwory naftowe: frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30°C - 250°C Stabilność oksydacyjna\nZakres (60 – 700) minut\nMetoda okresu indukcyjnego PN-EN ISO 7536:2011 Paliwa ciekle: benzyna bezolowiowa, Inne przetwory naftowe: frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30°C - 250°C Stabilnosc oksydacyjna\nZakres (60 – 700) minut\nMetoda okresu indukcyjnego PN-EN ISO 7536:2011","categories":["petro"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb572","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Zawartość manganu","parameters":[{"name":"Zakres","range":"(2,0 – 4,0) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Zawartość manganu\nZakres (2,0 – 4,0) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-EN 16135 :2012","norm_bases":["PN-EN 16135 :2012"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Zawartość manganu\nZakres (2,0 – 4,0) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN 16135 :2012 Paliwa ciekle: benzyna bezolowiowa Zawartosc manganu\nZakres (2,0 – 4,0) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN 16135 :2012","categories":["petro"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb573","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Indeks lotności (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Indeks lotności (z obliczeń)","reference":"PN-EN 228+A1:2017-06 p. 5.5.2","norm_bases":["PN-EN 228+A1:2017-06 p. 5.5.2"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Indeks lotności (z obliczeń) PN-EN 228+A1:2017-06 p. 5.5.2 Paliwa ciekle: benzyna bezolowiowa Indeks lotnosci (z obliczen) PN-EN 228+A1:2017-06 p. 5.5.2","categories":["petro"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb574","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Zawartość benzenu","parameters":[{"name":"Zakres","range":"(0,1 – 1,0) %(v/v)"}],"technique":"Metoda spektrometrii w zakresie podczerwieni IR","techniques":["Metoda spektrometrii w zakresie podczerwieni IR"],"computed":[],"activity":"Zawartość benzenu\nZakres (0,1 – 1,0) %(v/v)\nMetoda spektrometrii w zakresie podczerwieni IR","reference":"PN-EN 238:2000+A1:2008","norm_bases":["PN-EN 238:2000+A1:2008"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Zawartość benzenu\nZakres (0,1 – 1,0) %(v/v)\nMetoda spektrometrii w zakresie podczerwieni IR PN-EN 238:2000+A1:2008 Paliwa ciekle: benzyna bezolowiowa Zawartosc benzenu\nZakres (0,1 – 1,0) %(v/v)\nMetoda spektrometrii w zakresie podczerwieni IR PN-EN 238:2000+A1:2008","categories":["petro"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb575","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa, Inne przetwory naftowe: komponenty benzynowe","methodology":"Zawartość grup węglowodorów i związków tlenowych","parameters":[{"name":"całkowita zawartość węglowodorów"},{"name":"aromatycznych","range":"(10,0 – 50,0) %(v/v)"},{"name":"całkowita zawartość olefin:"},{"name":"Zakres","range":"(0,4 – 26,85) % (v/v)"},{"name":"zawartość benzenu","range":"(0,38 – 1,96) %(v/v)"},{"name":"zawartość związków tlenowych: ETBE","range":"(0,61 – 14,8) %(v/v)"},{"name":"MTBE","range":"(0,61 – 15,0) %(v/v)"},{"name":"ETOH","range":"(0,61 – 16,0) %(v/v)"},{"name":"Całkowita zawartość tlenu (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość grup węglowodorów i związków tlenowych\nZakres:\ncałkowita zawartość węglowodorów\naromatycznych (10,0 – 50,0) %(v/v)\ncałkowita zawartość olefin:\nZakres (0,4 – 26,85) % (v/v)\nzawartość benzenu (0,38 – 1,96) %(v/v)\nzawartość związków tlenowych: ETBE (0,61 – 14,8) %(v/v)\nMTBE (0,61 – 15,0) %(v/v)\nETOH (0,61 – 16,0) %(v/v)\nCałkowita zawartość tlenu (z obliczeń)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN ISO 22854:2025-07 Procedura A","norm_bases":["PN-EN ISO 22854:2025-07 Procedura A"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa, Inne przetwory naftowe: komponenty benzynowe Zawartość grup węglowodorów i związków tlenowych\nZakres:\ncałkowita zawartość węglowodorów\naromatycznych (10,0 – 50,0) %(v/v)\ncałkowita zawartość olefin:\nZakres (0,4 – 26,85) % (v/v)\nzawartość benzenu (0,38 – 1,96) %(v/v)\nzawartość związków tlenowych: ETBE (0,61 – 14,8) %(v/v)\nMTBE (0,61 – 15,0) %(v/v)\nETOH (0,61 – 16,0) %(v/v)\nCałkowita zawartość tlenu (z obliczeń)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN ISO 22854:2025-07 Procedura A Paliwa ciekle: benzyna bezolowiowa, Inne przetwory naftowe: komponenty benzynowe Zawartosc grup weglowodorow i zwiazkow tlenowych\nZakres:\ncalkowita zawartosc weglowodorow\naromatycznych (10,0 – 50,0) %(v/v)\ncalkowita zawartosc olefin:\nZakres (0,4 – 26,85) % (v/v)\nzawartosc benzenu (0,38 – 1,96) %(v/v)\nzawartosc zwiazkow tlenowych: ETBE (0,61 – 14,8) %(v/v)\nMTBE (0,61 – 15,0) %(v/v)\nETOH (0,61 – 16,0) %(v/v)\nCalkowita zawartosc tlenu (z obliczen)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN ISO 22854:2025-07 Procedura A","categories":["petro"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb576","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych","methodology":"Gęstość w temperaturze 15°C","parameters":[{"name":"Zakres","range":"(700,0 – 860,0) kg/m3"}],"technique":"Metoda areometryczna","techniques":["Metoda areometryczna"],"computed":[],"activity":"Gęstość w temperaturze 15°C\nZakres (700,0 – 860,0) kg/m3\nMetoda areometryczna","reference":"ASTM D 1298-12b (2017)","norm_bases":["ASTM D 1298-12b (2017)"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych Gęstość w temperaturze 15°C\nZakres (700,0 – 860,0) kg/m3\nMetoda areometryczna ASTM D 1298-12b (2017) Paliwa ciekle: paliwo do turbinowych silnikow lotniczych Gestosc w temperaturze 15°C\nZakres (700,0 – 860,0) kg/m3\nMetoda areometryczna ASTM D 1298-12b (2017)","categories":["petro"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb577","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, benzyna lotnicza, paliwo do turbinowych silników lotniczych, Wyroby chemiczne: węglowodory aromatyczne, rozpuszczalniki, Inne przetwory naftowe: frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30oC - 300°C","methodology":"Gęstość w temperaturze 15°C i 20°C","parameters":[{"name":"Zakres","range":"(650,0 – 1100,0) kg/m3"}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"computed":[],"activity":"Gęstość w temperaturze 15°C i 20°C\nZakres (650,0 – 1100,0) kg/m3\nMetoda oscylacyjna","reference":"PN-EN ISO 12185:2024-08 | ASTM D 4052-22","norm_bases":["PN-EN ISO 12185:2024-08","ASTM D 4052-22"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, benzyna lotnicza, paliwo do turbinowych silników lotniczych, Wyroby chemiczne: węglowodory aromatyczne, rozpuszczalniki, Inne przetwory naftowe: frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30oC - 300°C Gęstość w temperaturze 15°C i 20°C\nZakres (650,0 – 1100,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08 | ASTM D 4052-22 Paliwa ciekle: olej napedowy, benzyna bezolowiowa, benzyna lotnicza, paliwo do turbinowych silnikow lotniczych, Wyroby chemiczne: weglowodory aromatyczne, rozpuszczalniki, Inne przetwory naftowe: frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30oC - 300°C Gestosc w temperaturze 15°C i 20°C\nZakres (650,0 – 1100,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08 | ASTM D 4052-22","categories":["petro"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb578","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa, benzyna lotnicza, paliwo do turbinowych silników lotniczych, Inne przetwory naftowe: frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30oC - 300oC","methodology":"Zawartość żywic","parameters":[{"name":"Zakres","range":"(1 – 10) mg/100ml"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość żywic\nZakres (1 – 10) mg/100ml\nMetoda wagowa","reference":"PN-EN ISO 6246:2017-05 +A1:2020-03","norm_bases":["PN-EN ISO 6246:2017-05 +A1:2020-03"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa, benzyna lotnicza, paliwo do turbinowych silników lotniczych, Inne przetwory naftowe: frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30oC - 300oC Zawartość żywic\nZakres (1 – 10) mg/100ml\nMetoda wagowa PN-EN ISO 6246:2017-05 +A1:2020-03 Paliwa ciekle: benzyna bezolowiowa, benzyna lotnicza, paliwo do turbinowych silnikow lotniczych, Inne przetwory naftowe: frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30oC - 300oC Zawartosc zywic\nZakres (1 – 10) mg/100ml\nMetoda wagowa PN-EN ISO 6246:2017-05 +A1:2020-03","categories":["petro"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb579","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa, Inne przetwory naftowe: frakcje naftowe o zakresie temperatur wrzenia 30°C - 225°C, komponenty benzynowe","methodology":"Skład szczegółowy dla węglowodorów do n-nonanu (C9), Węglowodory niearomatyczne (0,05 – 24,00) %(m/m), Węglowodory aromatyczne (1,00 – 90,00) %(m/m)","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Skład szczegółowy dla węglowodorów do n-nonanu (C9), Węglowodory niearomatyczne (0,05 – 24,00) %(m/m), Węglowodory aromatyczne (1,00 – 90,00) %(m/m)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"ASTM D 5134-21","norm_bases":["ASTM D 5134-21"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa, Inne przetwory naftowe: frakcje naftowe o zakresie temperatur wrzenia 30°C - 225°C, komponenty benzynowe Skład szczegółowy dla węglowodorów do n-nonanu (C9), Węglowodory niearomatyczne (0,05 – 24,00) %(m/m), Węglowodory aromatyczne (1,00 – 90,00) %(m/m)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) ASTM D 5134-21 Paliwa ciekle: benzyna bezolowiowa, Inne przetwory naftowe: frakcje naftowe o zakresie temperatur wrzenia 30°C - 225°C, komponenty benzynowe Sklad szczegolowy dla weglowodorow do n-nonanu (C9), Weglowodory niearomatyczne (0,05 – 24,00) %(m/m), Weglowodory aromatyczne (1,00 – 90,00) %(m/m)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) ASTM D 5134-21","categories":["petro"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb57a","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, Inne przetwory naftowe: destylaty naftowe","methodology":"Zawartość węglowodorów aromatycznych","parameters":[{"name":"jednopierścieniowe (MAH)"},{"name":"Zakres","range":"(7,0 – 30) %(m/m)"},{"name":"dwupierścieniowe (DAH)","range":"(1,0 – 9.7) %(m/m)"},{"name":"trój- i wielopierścieniowe (T+ AH)","range":"(0,1 – 2,0) %(m/m)"},{"name":"wielopierścieniowe (POLY-AH)","range":"(1,1 – 11,8) %(m/m)"},{"name":"Sumaryczna zawartość węglowodorów aromatycznych (z obliczeń)"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją refraktometryczną (HPLC-RID)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją refraktometryczną (HPLC-RID)"],"computed":[],"activity":"Zawartość węglowodorów aromatycznych\nZakres:\njednopierścieniowe (MAH)\nZakres (7,0 – 30) %(m/m)\ndwupierścieniowe (DAH) (1,0 – 9.7) %(m/m)\ntrój- i wielopierścieniowe (T+ AH) (0,1 – 2,0) %(m/m)\nwielopierścieniowe (POLY-AH) (1,1 – 11,8) %(m/m)\nSumaryczna zawartość węglowodorów aromatycznych (z obliczeń)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją refraktometryczną (HPLC-RID)","reference":"PN-EN 12916:2024-08 Procedura A","norm_bases":["PN-EN 12916:2024-08 Procedura A"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, Inne przetwory naftowe: destylaty naftowe Zawartość węglowodorów aromatycznych\nZakres:\njednopierścieniowe (MAH)\nZakres (7,0 – 30) %(m/m)\ndwupierścieniowe (DAH) (1,0 – 9.7) %(m/m)\ntrój- i wielopierścieniowe (T+ AH) (0,1 – 2,0) %(m/m)\nwielopierścieniowe (POLY-AH) (1,1 – 11,8) %(m/m)\nSumaryczna zawartość węglowodorów aromatycznych (z obliczeń)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją refraktometryczną (HPLC-RID) PN-EN 12916:2024-08 Procedura A Paliwa ciekle: olej napedowy, Inne przetwory naftowe: destylaty naftowe Zawartosc weglowodorow aromatycznych\nZakres:\njednopierscieniowe (MAH)\nZakres (7,0 – 30) %(m/m)\ndwupierscieniowe (DAH) (1,0 – 9.7) %(m/m)\ntroj- i wielopierscieniowe (T+ AH) (0,1 – 2,0) %(m/m)\nwielopierscieniowe (POLY-AH) (1,1 – 11,8) %(m/m)\nSumaryczna zawartosc weglowodorow aromatycznych (z obliczen)\nMetoda wysokosprawnej chromatografii cieczowej z detekcja refraktometryczna (HPLC-RID) PN-EN 12916:2024-08 Procedura A","categories":["petro"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb57b","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Liczba cetanowa","parameters":[{"name":"Zakres","range":"50,0 – 60,0"}],"technique":"Metoda silnikowa","techniques":["Metoda silnikowa"],"computed":[],"activity":"Liczba cetanowa\nZakres 50,0 – 60,0\nMetoda silnikowa","reference":"PN-EN ISO 5165:2021-02","norm_bases":["PN-EN ISO 5165:2021-02"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Liczba cetanowa\nZakres 50,0 – 60,0\nMetoda silnikowa PN-EN ISO 5165:2021-02 Paliwa ciekle: olej napedowy, biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Liczba cetanowa\nZakres 50,0 – 60,0\nMetoda silnikowa PN-EN ISO 5165:2021-02","categories":["petro"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb57c","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki","methodology":"Zawartość estrów metylowych kwasów tłuszczowych (FAME)","parameters":[{"name":"Zakres","range":"(0,05 – 10,0) %(v/v)"}],"technique":"Metoda spektrometrii w zakresie podczerwieni IR","techniques":["Metoda spektrometrii w zakresie podczerwieni IR"],"computed":[],"activity":"Zawartość estrów metylowych kwasów tłuszczowych (FAME)\nZakres (0,05 – 10,0) %(v/v)\nMetoda spektrometrii w zakresie podczerwieni IR","reference":"PN-EN 14078:2014-06","norm_bases":["PN-EN 14078:2014-06"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki Zawartość estrów metylowych kwasów tłuszczowych (FAME)\nZakres (0,05 – 10,0) %(v/v)\nMetoda spektrometrii w zakresie podczerwieni IR PN-EN 14078:2014-06 Paliwa ciekle: olej napedowy, olej opalowy lekki Zawartosc estrow metylowych kwasow tluszczowych (FAME)\nZakres (0,05 – 10,0) %(v/v)\nMetoda spektrometrii w zakresie podczerwieni IR PN-EN 14078:2014-06","categories":["petro"],"row_index":55,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb57d","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: lekki olej opałowy, mieszanki lekkiego oleju opałowego z nieoznaczonym olejem mineralnym","methodology":"Zawartość barwnika Solvent Red 19","parameters":[{"name":"Zakres","range":"(1,0 – 10,0) mg/l"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV/VIS)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV/VIS)"],"computed":[],"activity":"Zawartość barwnika Solvent Red 19\nZakres (1,0 – 10,0) mg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV/VIS)","reference":"DIN 51430:2018-02","norm_bases":["DIN 51430:2018-02"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: lekki olej opałowy, mieszanki lekkiego oleju opałowego z nieoznaczonym olejem mineralnym Zawartość barwnika Solvent Red 19\nZakres (1,0 – 10,0) mg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV/VIS) DIN 51430:2018-02 Paliwa ciekle: lekki olej opalowy, mieszanki lekkiego oleju opalowego z nieoznaczonym olejem mineralnym Zawartosc barwnika Solvent Red 19\nZakres (1,0 – 10,0) mg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC-UV/VIS) DIN 51430:2018-02","categories":["petro"],"row_index":56,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb57e","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, benzyna lotnicza, paliwo do turbinowych silników lotniczych, Inne przetwory naftowe: komponenty benzynowe, frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30°C - 350°C","methodology":"Działanie korodujące na miedź","parameters":[{"name":"klasa korozji","range":"(1 – 4)"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Działanie korodujące na miedź\nklasa korozji (1 – 4)\nMetoda wizualna","reference":"PN-EN ISO 2160:2004","norm_bases":["PN-EN ISO 2160:2004"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, benzyna lotnicza, paliwo do turbinowych silników lotniczych, Inne przetwory naftowe: komponenty benzynowe, frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30°C - 350°C Działanie korodujące na miedź\nklasa korozji (1 – 4)\nMetoda wizualna PN-EN ISO 2160:2004 Paliwa ciekle: olej napedowy, benzyna bezolowiowa, benzyna lotnicza, paliwo do turbinowych silnikow lotniczych, Inne przetwory naftowe: komponenty benzynowe, frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30°C - 350°C Dzialanie korodujace na miedz\nklasa korozji (1 – 4)\nMetoda wizualna PN-EN ISO 2160:2004","categories":["petro","materials"],"row_index":57,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb57f","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, benzyna lotnicza, paliwo do turbinowych silników lotniczych, Inne przetwory naftowe: komponenty benzynowe, frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30°C - 350°C","methodology":"Działanie korodujące na miedź","parameters":[{"name":"klasa korozji","range":"(1a – 4c)"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Działanie korodujące na miedź\nklasa korozji (1a – 4c)\nMetoda wizualna","reference":"ASTM D 130-19","norm_bases":["ASTM D 130-19"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, benzyna lotnicza, paliwo do turbinowych silników lotniczych, Inne przetwory naftowe: komponenty benzynowe, frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30°C - 350°C Działanie korodujące na miedź\nklasa korozji (1a – 4c)\nMetoda wizualna ASTM D 130-19 Paliwa ciekle: olej napedowy, benzyna bezolowiowa, benzyna lotnicza, paliwo do turbinowych silnikow lotniczych, Inne przetwory naftowe: komponenty benzynowe, frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30°C - 350°C Dzialanie korodujace na miedz\nklasa korozji (1a – 4c)\nMetoda wizualna ASTM D 130-19","categories":["petro","materials"],"row_index":58,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb580","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, benzyna lotnicza, paliwo do turbinowych silników lotniczych, Inne przetwory naftowe: komponenty benzynowe, frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30°C - 350°C","methodology":"Zawartość siarki","parameters":[{"name":"Zakres","range":"(20,0 – 500) mg/kg"}],"technique":"Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali","techniques":["Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali"],"computed":[],"activity":"Zawartość siarki\nZakres (20,0 – 500) mg/kg\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali","reference":"PN-EN ISO 20884:2020-03 +A1:2022-03","norm_bases":["PN-EN ISO 20884:2020-03 +A1:2022-03"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, benzyna lotnicza, paliwo do turbinowych silników lotniczych, Inne przetwory naftowe: komponenty benzynowe, frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30°C - 350°C Zawartość siarki\nZakres (20,0 – 500) mg/kg\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali PN-EN ISO 20884:2020-03 +A1:2022-03 Paliwa ciekle: olej napedowy, benzyna bezolowiowa, benzyna lotnicza, paliwo do turbinowych silnikow lotniczych, Inne przetwory naftowe: komponenty benzynowe, frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30°C - 350°C Zawartosc siarki\nZakres (20,0 – 500) mg/kg\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersja fali PN-EN ISO 20884:2020-03 +A1:2022-03","categories":["petro"],"row_index":59,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb581","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, benzyna lotnicza, paliwo do turbinowych silników lotniczych, Inne przetwory naftowe: komponenty benzynowe, frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30°C - 350°C","methodology":"Zawartość siarki","parameters":[{"name":"Zakres","range":"(0,0020 – 2,50) % (m/m)"}],"technique":"Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali","techniques":["Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali"],"computed":[],"activity":"Zawartość siarki\nZakres (0,0020 – 2,50) % (m/m)\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali","reference":"PN-EN ISO 14596:2009","norm_bases":["PN-EN ISO 14596:2009"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, benzyna lotnicza, paliwo do turbinowych silników lotniczych, Inne przetwory naftowe: komponenty benzynowe, frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30°C - 350°C Zawartość siarki\nZakres (0,0020 – 2,50) % (m/m)\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali PN-EN ISO 14596:2009 Paliwa ciekle: olej napedowy, benzyna bezolowiowa, benzyna lotnicza, paliwo do turbinowych silnikow lotniczych, Inne przetwory naftowe: komponenty benzynowe, frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30°C - 350°C Zawartosc siarki\nZakres (0,0020 – 2,50) % (m/m)\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersja fali PN-EN ISO 14596:2009","categories":["petro"],"row_index":60,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb582","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa, paliwo do turbinowych silników lotniczych","methodology":"Zawartość grup węglowodorów","parameters":[{"name":"węglowodory aromatyczne"},{"name":"Zakres","range":"(5,0 – 70,0) %(v/v)"},{"name":"węglowodory olefinowe","range":"(1,0 – 55,0) %(v/v)"}],"technique":"Metoda chromatografii żelowej (FIA)","techniques":["Metoda chromatografii żelowej (FIA)"],"computed":[],"activity":"Zawartość grup węglowodorów\nZakres:\nwęglowodory aromatyczne\nZakres (5,0 – 70,0) %(v/v)\nwęglowodory olefinowe (1,0 – 55,0) %(v/v)\nMetoda chromatografii żelowej (FIA)","reference":"ASTM D 1319-20a | PN-EN 15553+A1:2025-05","norm_bases":["ASTM D 1319-20a","PN-EN 15553+A1:2025-05"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa, paliwo do turbinowych silników lotniczych Zawartość grup węglowodorów\nZakres:\nwęglowodory aromatyczne\nZakres (5,0 – 70,0) %(v/v)\nwęglowodory olefinowe (1,0 – 55,0) %(v/v)\nMetoda chromatografii żelowej (FIA) ASTM D 1319-20a | PN-EN 15553+A1:2025-05 Paliwa ciekle: benzyna bezolowiowa, paliwo do turbinowych silnikow lotniczych Zawartosc grup weglowodorow\nZakres:\nweglowodory aromatyczne\nZakres (5,0 – 70,0) %(v/v)\nweglowodory olefinowe (1,0 – 55,0) %(v/v)\nMetoda chromatografii zelowej (FIA) ASTM D 1319-20a | PN-EN 15553+A1:2025-05","categories":["petro"],"row_index":61,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb583","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, benzyna lotnicza, paliwo do turbinowych silników lotniczych, Inne przetwory naftowe: frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30°C - 350°C","methodology":"Skład frakcyjny","parameters":[{"name":"Zakres","range":"(30,0 – 360,0) °C"}],"technique":"Metoda destylacyjna automatyczna","techniques":["Metoda destylacyjna automatyczna"],"computed":[],"activity":"Skład frakcyjny\nZakres (30,0 – 360,0) °C\nMetoda destylacyjna automatyczna","reference":"ASTM D 86-23aɛ2","norm_bases":["ASTM D 86-23aɛ2"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, benzyna lotnicza, paliwo do turbinowych silników lotniczych, Inne przetwory naftowe: frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30°C - 350°C Skład frakcyjny\nZakres (30,0 – 360,0) °C\nMetoda destylacyjna automatyczna ASTM D 86-23aɛ2 Paliwa ciekle: olej napedowy, benzyna bezolowiowa, benzyna lotnicza, paliwo do turbinowych silnikow lotniczych, Inne przetwory naftowe: frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30°C - 350°C Sklad frakcyjny\nZakres (30,0 – 360,0) °C\nMetoda destylacyjna automatyczna ASTM D 86-23aɛ2","categories":["petro"],"row_index":62,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb584","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, benzyna lotnicza, paliwo do turbinowych silników lotniczych, Inne przetwory naftowe: frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30°C - 350°C","methodology":"Zawartość siarki","parameters":[{"name":"Zakres","range":"(3,0 – 500) mg/kg"}],"technique":"Metoda fluorescencji w nadfiolecie","techniques":["Metoda fluorescencji w nadfiolecie"],"computed":[],"activity":"Zawartość siarki\nZakres (3,0 – 500) mg/kg\nMetoda fluorescencji w nadfiolecie","reference":"PN-EN ISO 20846:2020-03","norm_bases":["PN-EN ISO 20846:2020-03"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, benzyna lotnicza, paliwo do turbinowych silników lotniczych, Inne przetwory naftowe: frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30°C - 350°C Zawartość siarki\nZakres (3,0 – 500) mg/kg\nMetoda fluorescencji w nadfiolecie PN-EN ISO 20846:2020-03 Paliwa ciekle: olej napedowy, benzyna bezolowiowa, benzyna lotnicza, paliwo do turbinowych silnikow lotniczych, Inne przetwory naftowe: frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30°C - 350°C Zawartosc siarki\nZakres (3,0 – 500) mg/kg\nMetoda fluorescencji w nadfiolecie PN-EN ISO 20846:2020-03","categories":["petro"],"row_index":63,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb585","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, benzyna lotnicza, paliwo do turbinowych silników lotniczych, Inne przetwory naftowe: frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30°C - 350°C","methodology":"Zawartość siarki","parameters":[{"name":"Zakres","range":"(1,0 – 1000) mg/kg"}],"technique":"Metoda fluorescencji w nadfiolecie","techniques":["Metoda fluorescencji w nadfiolecie"],"computed":[],"activity":"Zawartość siarki\nZakres (1,0 – 1000) mg/kg\nMetoda fluorescencji w nadfiolecie","reference":"ASTM D 5453-24","norm_bases":["ASTM D 5453-24"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, benzyna lotnicza, paliwo do turbinowych silników lotniczych, Inne przetwory naftowe: frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30°C - 350°C Zawartość siarki\nZakres (1,0 – 1000) mg/kg\nMetoda fluorescencji w nadfiolecie ASTM D 5453-24 Paliwa ciekle: olej napedowy, benzyna bezolowiowa, benzyna lotnicza, paliwo do turbinowych silnikow lotniczych, Inne przetwory naftowe: frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30°C - 350°C Zawartosc siarki\nZakres (1,0 – 1000) mg/kg\nMetoda fluorescencji w nadfiolecie ASTM D 5453-24","categories":["petro"],"row_index":64,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb586","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych","methodology":"Zawartość siarki całkowitej","parameters":[{"name":"Zakres","range":"(0,0050 – 0,300) %(m/m)"}],"technique":"Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii","techniques":["Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii"],"computed":[],"activity":"Zawartość siarki całkowitej\nZakres (0,0050 – 0,300) %(m/m)\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii","reference":"ASTM D 4294-24","norm_bases":["ASTM D 4294-24"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych Zawartość siarki całkowitej\nZakres (0,0050 – 0,300) %(m/m)\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii ASTM D 4294-24 Paliwa ciekle: paliwo do turbinowych silnikow lotniczych Zawartosc siarki calkowitej\nZakres (0,0050 – 0,300) %(m/m)\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersja energii ASTM D 4294-24","categories":["petro"],"row_index":65,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb587","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych","methodology":"Największa wysokość niekopcącego płomienia","parameters":[{"name":"Zakres","range":"(17,0 – 30,0) mm"}],"technique":"Metoda optyczna; Metoda wizualna","techniques":["Metoda optyczna","Metoda wizualna"],"computed":[],"activity":"Największa wysokość niekopcącego płomienia\nZakres (17,0 – 30,0) mm\nMetoda optyczna; Metoda wizualna","reference":"ASTM D 1322-25","norm_bases":["ASTM D 1322-25"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych Największa wysokość niekopcącego płomienia\nZakres (17,0 – 30,0) mm\nMetoda optyczna; Metoda wizualna ASTM D 1322-25 Paliwa ciekle: paliwo do turbinowych silnikow lotniczych Najwieksza wysokosc niekopcacego plomienia\nZakres (17,0 – 30,0) mm\nMetoda optyczna; Metoda wizualna ASTM D 1322-25","categories":["petro"],"row_index":66,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb588","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych","methodology":"Kwasowość","parameters":[{"name":"Zakres","range":"(0,0001 – 0,100) mg KOH/g"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Kwasowość\nZakres (0,0001 – 0,100) mg KOH/g\nMetoda miareczkowa","reference":"ASTM D 3242-23","norm_bases":["ASTM D 3242-23"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych Kwasowość\nZakres (0,0001 – 0,100) mg KOH/g\nMetoda miareczkowa ASTM D 3242-23 Paliwa ciekle: paliwo do turbinowych silnikow lotniczych Kwasowosc\nZakres (0,0001 – 0,100) mg KOH/g\nMetoda miareczkowa ASTM D 3242-23","categories":["petro"],"row_index":67,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb589","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych","methodology":"Wartość opałowa (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wartość opałowa (z obliczeń)","reference":"ASTM D 3338/D 3338M-20a","norm_bases":["ASTM D 3338/D 3338M-20a"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych Wartość opałowa (z obliczeń) ASTM D 3338/D 3338M-20a Paliwa ciekle: paliwo do turbinowych silnikow lotniczych Wartosc opalowa (z obliczen) ASTM D 3338/D 3338M-20a","categories":["petro"],"row_index":68,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb58a","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych","methodology":"Stabilność termooksydacyjna w temperaturze 260 °C","parameters":[{"name":"Osady na rurze 0 – 4 A, P Spadek ciśnienia","range":"(0,1 – 200) mmHg"}],"technique":"Metoda JFTOT","techniques":["Metoda JFTOT"],"computed":[],"activity":"Stabilność termooksydacyjna w temperaturze 260 °C\nOsady na rurze 0 – 4 A, P Spadek ciśnienia (0,1 – 200) mmHg\nMetoda JFTOT","reference":"ASTM D 3241-24","norm_bases":["ASTM D 3241-24"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych Stabilność termooksydacyjna w temperaturze 260 °C\nOsady na rurze 0 – 4 A, P Spadek ciśnienia (0,1 – 200) mmHg\nMetoda JFTOT ASTM D 3241-24 Paliwa ciekle: paliwo do turbinowych silnikow lotniczych Stabilnosc termooksydacyjna w temperaturze 260 °C\nOsady na rurze 0 – 4 A, P Spadek cisnienia (0,1 – 200) mmHg\nMetoda JFTOT ASTM D 3241-24","categories":["petro"],"row_index":69,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb58b","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych","methodology":"Właściwości separacyjne wody","parameters":[{"name":"Zakres","range":"70 – 100"}],"technique":"Metoda turbidymetryczna","techniques":["Metoda turbidymetryczna"],"computed":[],"activity":"Właściwości separacyjne wody\nZakres 70 – 100\nMetoda turbidymetryczna","reference":"ASTM D 3948-22","norm_bases":["ASTM D 3948-22"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych Właściwości separacyjne wody\nZakres 70 – 100\nMetoda turbidymetryczna ASTM D 3948-22 Paliwa ciekle: paliwo do turbinowych silnikow lotniczych Wlasciwosci separacyjne wody\nZakres 70 – 100\nMetoda turbidymetryczna ASTM D 3948-22","categories":["petro","water"],"row_index":70,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb58c","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych","methodology":"Smarność","parameters":[{"name":"Zakres","range":"(0,40 – 0,85) mm"}],"technique":"Metoda BOCLE","techniques":["Metoda BOCLE"],"computed":[],"activity":"Smarność\nZakres (0,40 – 0,85) mm\nMetoda BOCLE","reference":"ASTM D 5001-25","norm_bases":["ASTM D 5001-25"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych Smarność\nZakres (0,40 – 0,85) mm\nMetoda BOCLE ASTM D 5001-25 Paliwa ciekle: paliwo do turbinowych silnikow lotniczych Smarnosc\nZakres (0,40 – 0,85) mm\nMetoda BOCLE ASTM D 5001-25","categories":["petro"],"row_index":71,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb58d","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych","methodology":"Zawartość cząstek stałych przy użyciu przenośnego automatycznego licznika cząstek","parameters":[{"name":"Zakres","range":"dla cząstek o średnicy:"},{"name":"≥ 4 μm","range":"(216 – 45061) liczba cząstek"},{"name":"≥ 6 μm","range":"(74 – 22483) liczba cząstek"},{"name":"≥ 14 μm","range":"(9 – 4105) liczba cząstek"},{"name":"≥ 21 μm","range":"(2 – 1444) liczba cząstek"},{"name":"≥ 25 μm","range":"(1 – 776) liczba cząstek"},{"name":"≥ 30 μm","range":"(1 – 365) liczba cząstek"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Zawartość cząstek stałych przy użyciu przenośnego automatycznego licznika cząstek\nZakres:\nZakres dla cząstek o średnicy:\n≥ 4 μm (216 – 45061) liczba cząstek\n≥ 6 μm (74 – 22483) liczba cząstek\n≥ 14 μm (9 – 4105) liczba cząstek\n≥ 21 μm (2 – 1444) liczba cząstek\n≥ 25 μm (1 – 776) liczba cząstek\n≥ 30 μm (1 – 365) liczba cząstek\nMetoda optyczna","reference":"IP 565-13","norm_bases":["IP 565-13"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych Zawartość cząstek stałych przy użyciu przenośnego automatycznego licznika cząstek\nZakres:\nZakres dla cząstek o średnicy:\n≥ 4 μm (216 – 45061) liczba cząstek\n≥ 6 μm (74 – 22483) liczba cząstek\n≥ 14 μm (9 – 4105) liczba cząstek\n≥ 21 μm (2 – 1444) liczba cząstek\n≥ 25 μm (1 – 776) liczba cząstek\n≥ 30 μm (1 – 365) liczba cząstek\nMetoda optyczna IP 565-13 Paliwa ciekle: paliwo do turbinowych silnikow lotniczych Zawartosc czastek stalych przy uzyciu przenosnego automatycznego licznika czastek\nZakres:\nZakres dla czastek o srednicy:\n≥ 4 μm (216 – 45061) liczba czastek\n≥ 6 μm (74 – 22483) liczba czastek\n≥ 14 μm (9 – 4105) liczba czastek\n≥ 21 μm (2 – 1444) liczba czastek\n≥ 25 μm (1 – 776) liczba czastek\n≥ 30 μm (1 – 365) liczba czastek\nMetoda optyczna IP 565-13","categories":["petro"],"row_index":72,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb58e","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych","methodology":"Zawartość wodoru (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość wodoru (z obliczeń)","reference":"ASTM D 3343-22","norm_bases":["ASTM D 3343-22"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych Zawartość wodoru (z obliczeń) ASTM D 3343-22 Paliwa ciekle: paliwo do turbinowych silnikow lotniczych Zawartosc wodoru (z obliczen) ASTM D 3343-22","categories":["petro"],"row_index":73,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb58f","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych","methodology":"Zawartość dodatku przeciwoblodzeniowego","parameters":[{"name":"Zakres","range":"(0,01 – 0,25) %(v/v)"}],"technique":"Metoda refraktometryczna","techniques":["Metoda refraktometryczna"],"computed":[],"activity":"Zawartość dodatku przeciwoblodzeniowego\nZakres (0,01 – 0,25) %(v/v)\nMetoda refraktometryczna","reference":"ASTM D 5006-25","norm_bases":["ASTM D 5006-25"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych Zawartość dodatku przeciwoblodzeniowego\nZakres (0,01 – 0,25) %(v/v)\nMetoda refraktometryczna ASTM D 5006-25 Paliwa ciekle: paliwo do turbinowych silnikow lotniczych Zawartosc dodatku przeciwoblodzeniowego\nZakres (0,01 – 0,25) %(v/v)\nMetoda refraktometryczna ASTM D 5006-25","categories":["petro"],"row_index":74,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb590","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych","methodology":"Zawartość estrów metylowych kwasów tłuszczowych (FAME)","parameters":[{"name":"Zakres","range":"(10,0 – 100,0) mg/kg"}],"technique":"Metoda spektrometrii w podczerwieni","techniques":["Metoda spektrometrii w podczerwieni"],"computed":[],"activity":"Zawartość estrów metylowych kwasów tłuszczowych (FAME)\nZakres (10,0 – 100,0) mg/kg\nMetoda spektrometrii w podczerwieni","reference":"ASTM D 7797-23","norm_bases":["ASTM D 7797-23"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych Zawartość estrów metylowych kwasów tłuszczowych (FAME)\nZakres (10,0 – 100,0) mg/kg\nMetoda spektrometrii w podczerwieni ASTM D 7797-23 Paliwa ciekle: paliwo do turbinowych silnikow lotniczych Zawartosc estrow metylowych kwasow tluszczowych (FAME)\nZakres (10,0 – 100,0) mg/kg\nMetoda spektrometrii w podczerwieni ASTM D 7797-23","categories":["petro"],"row_index":75,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb591","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych","methodology":"Wygląd","parameters":[],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Wygląd\nMetoda wizualna","reference":"NO-91-A258-1:2024 p. 2.1","norm_bases":["NO-91-A258-1:2024 p. 2.1"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych Wygląd\nMetoda wizualna NO-91-A258-1:2024 p. 2.1 Paliwa ciekle: paliwo do turbinowych silnikow lotniczych Wyglad\nMetoda wizualna NO-91-A258-1:2024 p. 2.1","categories":["petro"],"row_index":76,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb592","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych, Inne przetwory naftowe: produkty naftowe o zakresie temperatur wrzenia 15°C - 370°C","methodology":"Temperatura zapłonu","parameters":[{"name":"Zakres","range":"(4,0 – 70,0) °C"}],"technique":"Metoda zamkniętego tygla TAG","techniques":["Metoda zamkniętego tygla TAG"],"computed":[],"activity":"Temperatura zapłonu\nZakres (4,0 – 70,0) °C\nMetoda zamkniętego tygla TAG","reference":"ASTM D 56-22","norm_bases":["ASTM D 56-22"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych, Inne przetwory naftowe: produkty naftowe o zakresie temperatur wrzenia 15°C - 370°C Temperatura zapłonu\nZakres (4,0 – 70,0) °C\nMetoda zamkniętego tygla TAG ASTM D 56-22 Paliwa ciekle: paliwo do turbinowych silnikow lotniczych, Inne przetwory naftowe: produkty naftowe o zakresie temperatur wrzenia 15°C - 370°C Temperatura zaplonu\nZakres (4,0 – 70,0) °C\nMetoda zamknietego tygla TAG ASTM D 56-22","categories":["petro"],"row_index":77,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb593","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych","methodology":"Przewodność właściwa","parameters":[{"name":"Zakres","range":"(1 – 800) pS/m"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność właściwa\nZakres (1 – 800) pS/m\nMetoda konduktometryczna","reference":"ASTM D 2624-24","norm_bases":["ASTM D 2624-24"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych Przewodność właściwa\nZakres (1 – 800) pS/m\nMetoda konduktometryczna ASTM D 2624-24 Paliwa ciekle: paliwo do turbinowych silnikow lotniczych Przewodnosc wlasciwa\nZakres (1 – 800) pS/m\nMetoda konduktometryczna ASTM D 2624-24","categories":["petro"],"row_index":78,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb594","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych, Inne przetwory naftowe: produkty naftowe o zakresie temperatur wrzenia 100°C - 350°C, destylaty naftowe","methodology":"Lepkość kinematyczna w temp. (-20) °C","parameters":[{"name":"Zakres","range":"(2,000 – 8,000) mm2/s"}],"technique":"Metoda kapilarna","techniques":["Metoda kapilarna"],"computed":[],"activity":"Lepkość kinematyczna w temp. (-20) °C\nZakres (2,000 – 8,000) mm2/s\nMetoda kapilarna","reference":"ASTM D 445-24","norm_bases":["ASTM D 445-24"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych, Inne przetwory naftowe: produkty naftowe o zakresie temperatur wrzenia 100°C - 350°C, destylaty naftowe Lepkość kinematyczna w temp. (-20) °C\nZakres (2,000 – 8,000) mm2/s\nMetoda kapilarna ASTM D 445-24 Paliwa ciekle: paliwo do turbinowych silnikow lotniczych, Inne przetwory naftowe: produkty naftowe o zakresie temperatur wrzenia 100°C - 350°C, destylaty naftowe Lepkosc kinematyczna w temp. (-20) °C\nZakres (2,000 – 8,000) mm2/s\nMetoda kapilarna ASTM D 445-24","categories":["petro"],"row_index":79,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb595","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna lotnicza, paliwo do turbinowych silników lotniczych, Inne przetwory naftowe: produkty naftowe o zakresie temperatur wrzenia 15°C - 350°C","methodology":"Zawartość żywic","parameters":[{"name":"Zakres","range":"(1 – 10) mg/100ml"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość żywic\nZakres (1 – 10) mg/100ml\nMetoda wagowa","reference":"ASTM D 381-25","norm_bases":["ASTM D 381-25"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna lotnicza, paliwo do turbinowych silników lotniczych, Inne przetwory naftowe: produkty naftowe o zakresie temperatur wrzenia 15°C - 350°C Zawartość żywic\nZakres (1 – 10) mg/100ml\nMetoda wagowa ASTM D 381-25 Paliwa ciekle: benzyna lotnicza, paliwo do turbinowych silnikow lotniczych, Inne przetwory naftowe: produkty naftowe o zakresie temperatur wrzenia 15°C - 350°C Zawartosc zywic\nZakres (1 – 10) mg/100ml\nMetoda wagowa ASTM D 381-25","categories":["petro"],"row_index":80,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb596","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych","methodology":"Reakcja paliwa z wodą i ocena powierzchni międzyfazowej","parameters":[],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Reakcja paliwa z wodą i ocena powierzchni międzyfazowej\nMetoda wizualna","reference":"ASTM D 1094-24","norm_bases":["ASTM D 1094-24"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych Reakcja paliwa z wodą i ocena powierzchni międzyfazowej\nMetoda wizualna ASTM D 1094-24 Paliwa ciekle: paliwo do turbinowych silnikow lotniczych Reakcja paliwa z woda i ocena powierzchni miedzyfazowej\nMetoda wizualna ASTM D 1094-24","categories":["petro"],"row_index":81,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb597","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych","methodology":"Temperatura krystalizacji","parameters":[{"name":"[(-75,0)","range":"(-42,0)] oC"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Temperatura krystalizacji\n[(-75,0) (-42,0)] oC\nMetoda optyczna","reference":"ASTM D 5972-25","norm_bases":["ASTM D 5972-25"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych Temperatura krystalizacji\n[(-75,0) (-42,0)] oC\nMetoda optyczna ASTM D 5972-25 Paliwa ciekle: paliwo do turbinowych silnikow lotniczych Temperatura krystalizacji\n[(-75,0) (-42,0)] oC\nMetoda optyczna ASTM D 5972-25","categories":["petro"],"row_index":82,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb598","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych","methodology":"Temperatura krystalizacji","parameters":[{"name":"[(-62,0)","range":"(-42,0)] oC"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Temperatura krystalizacji\n[(-62,0) (-42,0)] oC\nMetoda wizualna","reference":"ASTM D 2386-19","norm_bases":["ASTM D 2386-19"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych Temperatura krystalizacji\n[(-62,0) (-42,0)] oC\nMetoda wizualna ASTM D 2386-19 Paliwa ciekle: paliwo do turbinowych silnikow lotniczych Temperatura krystalizacji\n[(-62,0) (-42,0)] oC\nMetoda wizualna ASTM D 2386-19","categories":["petro"],"row_index":83,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb599","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych","methodology":"Zawartość siarki merkaptanowej","parameters":[{"name":"Zakres","range":"(0,0003 – 0,01) %(m/m)"}],"technique":"Metoda miareczkowania potencjometrycznego","techniques":["Metoda miareczkowania potencjometrycznego"],"computed":[],"activity":"Zawartość siarki merkaptanowej\nZakres (0,0003 – 0,01) %(m/m)\nMetoda miareczkowania potencjometrycznego","reference":"ASTM D 3227-24","norm_bases":["ASTM D 3227-24"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych Zawartość siarki merkaptanowej\nZakres (0,0003 – 0,01) %(m/m)\nMetoda miareczkowania potencjometrycznego ASTM D 3227-24 Paliwa ciekle: paliwo do turbinowych silnikow lotniczych Zawartosc siarki merkaptanowej\nZakres (0,0003 – 0,01) %(m/m)\nMetoda miareczkowania potencjometrycznego ASTM D 3227-24","categories":["petro"],"row_index":84,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb59a","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych, paliwo do turbinowych silników lotniczych zawierające dodatki do paliw","methodology":"Właściwości separacyjne wody","parameters":[{"name":"Zakres","range":"70 – 100"}],"technique":"Metoda turbidymetryczna","techniques":["Metoda turbidymetryczna"],"computed":[],"activity":"Właściwości separacyjne wody\nZakres 70 – 100\nMetoda turbidymetryczna","reference":"ASTM D 7224-23","norm_bases":["ASTM D 7224-23"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych, paliwo do turbinowych silników lotniczych zawierające dodatki do paliw Właściwości separacyjne wody\nZakres 70 – 100\nMetoda turbidymetryczna ASTM D 7224-23 Paliwa ciekle: paliwo do turbinowych silnikow lotniczych, paliwo do turbinowych silnikow lotniczych zawierajace dodatki do paliw Wlasciwosci separacyjne wody\nZakres 70 – 100\nMetoda turbidymetryczna ASTM D 7224-23","categories":["petro","water"],"row_index":85,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb59b","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych","methodology":"Zawartość węglowodorów aromatycznych","parameters":[{"name":"MAH","range":"(10,0 – 25,0) %(m/m)"},{"name":"MAH","range":"(10,0 – 25,0) %(v/v)"},{"name":"DAH","range":"(0,1 – 7,0) %(m/m)"},{"name":"DAH","range":"(0,1 – 6,5) %(v/v)"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją refraktometryczną (HPLC-RID)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją refraktometryczną (HPLC-RID)"],"computed":[],"activity":"Zawartość węglowodorów aromatycznych\nZakres:\nMAH (10,0 – 25,0) %(m/m)\nMAH (10,0 – 25,0) %(v/v)\nDAH (0,1 – 7,0) %(m/m)\nDAH (0,1 – 6,5) %(v/v)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją refraktometryczną (HPLC-RID)","reference":"ASTM D 6379-21e1","norm_bases":["ASTM D 6379-21e1"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych Zawartość węglowodorów aromatycznych\nZakres:\nMAH (10,0 – 25,0) %(m/m)\nMAH (10,0 – 25,0) %(v/v)\nDAH (0,1 – 7,0) %(m/m)\nDAH (0,1 – 6,5) %(v/v)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją refraktometryczną (HPLC-RID) ASTM D 6379-21e1 Paliwa ciekle: paliwo do turbinowych silnikow lotniczych Zawartosc weglowodorow aromatycznych\nZakres:\nMAH (10,0 – 25,0) %(m/m)\nMAH (10,0 – 25,0) %(v/v)\nDAH (0,1 – 7,0) %(m/m)\nDAH (0,1 – 6,5) %(v/v)\nMetoda wysokosprawnej chromatografii cieczowej z detekcja refraktometryczna (HPLC-RID) ASTM D 6379-21e1","categories":["petro"],"row_index":86,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb59c","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych","methodology":"Suma węglowodorów aromatycznych (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma węglowodorów aromatycznych (z obliczeń)","reference":"ASTM D 6379-21e1","norm_bases":["ASTM D 6379-21e1"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych Suma węglowodorów aromatycznych (z obliczeń) ASTM D 6379-21e1 Paliwa ciekle: paliwo do turbinowych silnikow lotniczych Suma weglowodorow aromatycznych (z obliczen) ASTM D 6379-21e1","categories":["petro"],"row_index":87,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb59d","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych, Inne przetwory naftowe: produkty naftowe o zakresie temperatur wrzenia 15°C - 350°C","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(+10) – (+30) wg skali Saybolt"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Barwa\nZakres (+10) – (+30) wg skali Saybolt\nMetoda wizualna","reference":"ASTM D 156-23","norm_bases":["ASTM D 156-23"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych, Inne przetwory naftowe: produkty naftowe o zakresie temperatur wrzenia 15°C - 350°C Barwa\nZakres (+10) – (+30) wg skali Saybolt\nMetoda wizualna ASTM D 156-23 Paliwa ciekle: paliwo do turbinowych silnikow lotniczych, Inne przetwory naftowe: produkty naftowe o zakresie temperatur wrzenia 15°C - 350°C Barwa\nZakres (+10) – (+30) wg skali Saybolt\nMetoda wizualna ASTM D 156-23","categories":["petro"],"row_index":88,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb59e","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych","methodology":"Zawartość cząstek stałych","parameters":[{"name":"Zakres","range":"(0,0 – 10,0) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość cząstek stałych\nZakres (0,0 – 10,0) mg/l\nMetoda wagowa","reference":"ASTM D 5452-23 | PN-V-04031:2000","norm_bases":["ASTM D 5452-23","PN-V-04031:2000"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych Zawartość cząstek stałych\nZakres (0,0 – 10,0) mg/l\nMetoda wagowa ASTM D 5452-23 | PN-V-04031:2000 Paliwa ciekle: paliwo do turbinowych silnikow lotniczych Zawartosc czastek stalych\nZakres (0,0 – 10,0) mg/l\nMetoda wagowa ASTM D 5452-23 | PN-V-04031:2000","categories":["petro"],"row_index":89,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb59f","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych","methodology":"Zawartość żywic obecnych","parameters":[{"name":"Zakres","range":"(1 – 10) mg/100ml"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość żywic obecnych\nZakres (1 – 10) mg/100ml\nMetoda wagowa","reference":"IP 540/08(2019)","norm_bases":["IP 540/08(2019)"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych Zawartość żywic obecnych\nZakres (1 – 10) mg/100ml\nMetoda wagowa IP 540/08(2019) Paliwa ciekle: paliwo do turbinowych silnikow lotniczych Zawartosc zywic obecnych\nZakres (1 – 10) mg/100ml\nMetoda wagowa IP 540/08(2019)","categories":["petro"],"row_index":90,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5a0","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych","methodology":"Zawartość węglowodorów naftalenowych","parameters":[{"name":"Zakres","range":"(0,08 – 2,0) %(v/v)"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość węglowodorów naftalenowych\nZakres (0,08 – 2,0) %(v/v)\nMetoda spektrofotometryczna","reference":"ASTM D 1840-24","norm_bases":["ASTM D 1840-24"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych Zawartość węglowodorów naftalenowych\nZakres (0,08 – 2,0) %(v/v)\nMetoda spektrofotometryczna ASTM D 1840-24 Paliwa ciekle: paliwo do turbinowych silnikow lotniczych Zawartosc weglowodorow naftalenowych\nZakres (0,08 – 2,0) %(v/v)\nMetoda spektrofotometryczna ASTM D 1840-24","categories":["petro"],"row_index":91,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5a1","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Inne przetwory naftowe: produkty naftowe o zakresie temperatur wrzenia 30°C - 380°C","methodology":"Liczba bromowa","parameters":[{"name":"Zakres","range":"(0,1 – 100) g/100 g próbki"}],"technique":"Metoda miareczkowania potencjometrycznego","techniques":["Metoda miareczkowania potencjometrycznego"],"computed":[],"activity":"Liczba bromowa\nZakres (0,1 – 100) g/100 g próbki\nMetoda miareczkowania potencjometrycznego","reference":"ASTM D 1159-23","norm_bases":["ASTM D 1159-23"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Inne przetwory naftowe: produkty naftowe o zakresie temperatur wrzenia 30°C - 380°C Liczba bromowa\nZakres (0,1 – 100) g/100 g próbki\nMetoda miareczkowania potencjometrycznego ASTM D 1159-23 Inne przetwory naftowe: produkty naftowe o zakresie temperatur wrzenia 30°C - 380°C Liczba bromowa\nZakres (0,1 – 100) g/100 g probki\nMetoda miareczkowania potencjometrycznego ASTM D 1159-23","categories":["other"],"row_index":92,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5a2","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Inne przetwory naftowe: produkty naftowe o zakresie temperatur wrzenia 30°C - 250°C, Wyroby chemiczne: węglowodory aromatyczne","methodology":"Barwa wyciągu kwaśnego","parameters":[{"name":"Zakres","range":"0 – 14"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Barwa wyciągu kwaśnego\nZakres 0 – 14\nMetoda wizualna","reference":"ASTM D 848-23","norm_bases":["ASTM D 848-23"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Inne przetwory naftowe: produkty naftowe o zakresie temperatur wrzenia 30°C - 250°C, Wyroby chemiczne: węglowodory aromatyczne Barwa wyciągu kwaśnego\nZakres 0 – 14\nMetoda wizualna ASTM D 848-23 Inne przetwory naftowe: produkty naftowe o zakresie temperatur wrzenia 30°C - 250°C, Wyroby chemiczne: weglowodory aromatyczne Barwa wyciagu kwasnego\nZakres 0 – 14\nMetoda wizualna ASTM D 848-23","categories":["other"],"row_index":93,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5a3","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Inne przetwory naftowe: produkty naftowe o zakresie temperatur wrzenia 30°C - 250°C, Wyroby chemiczne: węglowodory aromatyczne","methodology":"Barwa","parameters":[{"name":"Zakres","range":"1 – 10"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Barwa\nZakres 1 – 10\nMetoda wizualna","reference":"ASTM D 1209-25","norm_bases":["ASTM D 1209-25"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Inne przetwory naftowe: produkty naftowe o zakresie temperatur wrzenia 30°C - 250°C, Wyroby chemiczne: węglowodory aromatyczne Barwa\nZakres 1 – 10\nMetoda wizualna ASTM D 1209-25 Inne przetwory naftowe: produkty naftowe o zakresie temperatur wrzenia 30°C - 250°C, Wyroby chemiczne: weglowodory aromatyczne Barwa\nZakres 1 – 10\nMetoda wizualna ASTM D 1209-25","categories":["other"],"row_index":94,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5a4","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Inne przetwory naftowe: produkty naftowe o zakresie temperatur wrzenia 30°C - 250°C, Wyroby chemiczne: węglowodory aromatyczne","methodology":"Kwasowość","parameters":[],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Kwasowość\nMetoda wizualna","reference":"ASTM D 847-23","norm_bases":["ASTM D 847-23"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Inne przetwory naftowe: produkty naftowe o zakresie temperatur wrzenia 30°C - 250°C, Wyroby chemiczne: węglowodory aromatyczne Kwasowość\nMetoda wizualna ASTM D 847-23 Inne przetwory naftowe: produkty naftowe o zakresie temperatur wrzenia 30°C - 250°C, Wyroby chemiczne: weglowodory aromatyczne Kwasowosc\nMetoda wizualna ASTM D 847-23","categories":["other"],"row_index":95,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5a5","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Inne przetwory naftowe: produkty naftowe o zakresie temperatur wrzenia 30°C - 250°C, Wyroby chemiczne: węglowodory aromatyczne","methodology":"Zawartość tiofenu","parameters":[{"name":"Zakres","range":"(0,14 – 2,61) mg/kg"}],"technique":"Metoda chromatografii gazowej z pulsacyjną detekcją płomieniowo-fotometryczną (GC-PFPD)","techniques":["Metoda chromatografii gazowej z pulsacyjną detekcją płomieniowo-fotometryczną (GC-PFPD)"],"computed":[],"activity":"Zawartość tiofenu\nZakres (0,14 – 2,61) mg/kg\nMetoda chromatografii gazowej z pulsacyjną detekcją płomieniowo-fotometryczną (GC-PFPD)","reference":"ASTM D 4735-19","norm_bases":["ASTM D 4735-19"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Inne przetwory naftowe: produkty naftowe o zakresie temperatur wrzenia 30°C - 250°C, Wyroby chemiczne: węglowodory aromatyczne Zawartość tiofenu\nZakres (0,14 – 2,61) mg/kg\nMetoda chromatografii gazowej z pulsacyjną detekcją płomieniowo-fotometryczną (GC-PFPD) ASTM D 4735-19 Inne przetwory naftowe: produkty naftowe o zakresie temperatur wrzenia 30°C - 250°C, Wyroby chemiczne: weglowodory aromatyczne Zawartosc tiofenu\nZakres (0,14 – 2,61) mg/kg\nMetoda chromatografii gazowej z pulsacyjna detekcja plomieniowo-fotometryczna (GC-PFPD) ASTM D 4735-19","categories":["other"],"row_index":96,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5a6","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Inne przetwory naftowe: frakcje i/ lub produkty naftowe o zakresie temperatur wrzenia 30°C - 400°C, Wyroby chemiczne: węglowodory aromatyczne","methodology":"Zawartość chlorków","parameters":[{"name":"Zakres","range":"(0,3 – 10,0) mg/kg"}],"technique":"Metoda mikrokulometryczna","techniques":["Metoda mikrokulometryczna"],"computed":[],"activity":"Zawartość chlorków\nZakres (0,3 – 10,0) mg/kg\nMetoda mikrokulometryczna","reference":"UOP 779-08","norm_bases":["UOP 779-08"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Inne przetwory naftowe: frakcje i/ lub produkty naftowe o zakresie temperatur wrzenia 30°C - 400°C, Wyroby chemiczne: węglowodory aromatyczne Zawartość chlorków\nZakres (0,3 – 10,0) mg/kg\nMetoda mikrokulometryczna UOP 779-08 Inne przetwory naftowe: frakcje i/ lub produkty naftowe o zakresie temperatur wrzenia 30°C - 400°C, Wyroby chemiczne: weglowodory aromatyczne Zawartosc chlorkow\nZakres (0,3 – 10,0) mg/kg\nMetoda mikrokulometryczna UOP 779-08","categories":["other"],"row_index":97,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5a7","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Wyroby chemiczne: węglowodory aromatyczne, frakcje węglowodorów aromatycznych, Inne przetwory naftowe: lekkie komponenty benzynowe","methodology":"Całkowita zawartość siarki","parameters":[{"name":"Zakres","range":"(0,10 – 10,0) mg/kg"}],"technique":"Metoda fluorescencji w nadfiolecie","techniques":["Metoda fluorescencji w nadfiolecie"],"computed":[],"activity":"Całkowita zawartość siarki\nZakres (0,10 – 10,0) mg/kg\nMetoda fluorescencji w nadfiolecie","reference":"ASTM D 7183-23","norm_bases":["ASTM D 7183-23"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby chemiczne: węglowodory aromatyczne, frakcje węglowodorów aromatycznych, Inne przetwory naftowe: lekkie komponenty benzynowe Całkowita zawartość siarki\nZakres (0,10 – 10,0) mg/kg\nMetoda fluorescencji w nadfiolecie ASTM D 7183-23 Wyroby chemiczne: weglowodory aromatyczne, frakcje weglowodorow aromatycznych, Inne przetwory naftowe: lekkie komponenty benzynowe Calkowita zawartosc siarki\nZakres (0,10 – 10,0) mg/kg\nMetoda fluorescencji w nadfiolecie ASTM D 7183-23","categories":["other"],"row_index":98,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5a8","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Wyroby chemiczne: węglowodory aromatyczne","methodology":"Skład frakcyjny wraz z suchym punktem","parameters":[{"name":"Zakres","range":"(70,0 – 145,0) °C"}],"technique":"Metoda destylacyjna","techniques":["Metoda destylacyjna"],"computed":[],"activity":"Skład frakcyjny wraz z suchym punktem\nZakres (70,0 – 145,0) °C\nMetoda destylacyjna","reference":"ASTM D 850-21","norm_bases":["ASTM D 850-21"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby chemiczne: węglowodory aromatyczne Skład frakcyjny wraz z suchym punktem\nZakres (70,0 – 145,0) °C\nMetoda destylacyjna ASTM D 850-21 Wyroby chemiczne: weglowodory aromatyczne Sklad frakcyjny wraz z suchym punktem\nZakres (70,0 – 145,0) °C\nMetoda destylacyjna ASTM D 850-21","categories":["other"],"row_index":99,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5a9","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Wyroby chemiczne: węglowodory aromatyczne","methodology":"Zawartość chlorków","parameters":[{"name":"Zakres","range":"(1,0 – 25,0) mg/kg"}],"technique":"Metoda mikrokulometryczna","techniques":["Metoda mikrokulometryczna"],"computed":[],"activity":"Zawartość chlorków\nZakres (1,0 – 25,0) mg/kg\nMetoda mikrokulometryczna","reference":"ASTM D 5808-23","norm_bases":["ASTM D 5808-23"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby chemiczne: węglowodory aromatyczne Zawartość chlorków\nZakres (1,0 – 25,0) mg/kg\nMetoda mikrokulometryczna ASTM D 5808-23 Wyroby chemiczne: weglowodory aromatyczne Zawartosc chlorkow\nZakres (1,0 – 25,0) mg/kg\nMetoda mikrokulometryczna ASTM D 5808-23","categories":["other"],"row_index":100,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5aa","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Wyroby chemiczne: węglowodory aromatyczne","methodology":"Temperatura krzepnięcia benzenu","parameters":[{"name":"Zakres","range":"(5,10 – 5,50) °C"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Temperatura krzepnięcia benzenu\nZakres (5,10 – 5,50) °C\nMetoda wizualna","reference":"ASTM D 852-24","norm_bases":["ASTM D 852-24"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby chemiczne: węglowodory aromatyczne Temperatura krzepnięcia benzenu\nZakres (5,10 – 5,50) °C\nMetoda wizualna ASTM D 852-24 Wyroby chemiczne: weglowodory aromatyczne Temperatura krzepniecia benzenu\nZakres (5,10 – 5,50) °C\nMetoda wizualna ASTM D 852-24","categories":["other"],"row_index":101,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5ab","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Wyroby chemiczne: węglowodory aromatyczne","methodology":"Zawartość azotu","parameters":[{"name":"Zakres","range":"(0,10 – 1,20) mg/kg"}],"technique":"Metoda chemiluminescencyjna","techniques":["Metoda chemiluminescencyjna"],"computed":[],"activity":"Zawartość azotu\nZakres (0,10 – 1,20) mg/kg\nMetoda chemiluminescencyjna","reference":"ASTM D 7184-24","norm_bases":["ASTM D 7184-24"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby chemiczne: węglowodory aromatyczne Zawartość azotu\nZakres (0,10 – 1,20) mg/kg\nMetoda chemiluminescencyjna ASTM D 7184-24 Wyroby chemiczne: weglowodory aromatyczne Zawartosc azotu\nZakres (0,10 – 1,20) mg/kg\nMetoda chemiluminescencyjna ASTM D 7184-24","categories":["other"],"row_index":102,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5ac","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Wyroby chemiczne: węglowodory aromatyczne","methodology":"Indeks bromowy","parameters":[{"name":"Zakres","range":"(1,0 – 100,0) (mg Br/100g)"}],"technique":"Metoda miareczkowania kulometrycznego","techniques":["Metoda miareczkowania kulometrycznego"],"computed":[],"activity":"Indeks bromowy\nZakres (1,0 – 100,0) (mg Br/100g)\nMetoda miareczkowania kulometrycznego","reference":"ASTM D 1492-21","norm_bases":["ASTM D 1492-21"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby chemiczne: węglowodory aromatyczne Indeks bromowy\nZakres (1,0 – 100,0) (mg Br/100g)\nMetoda miareczkowania kulometrycznego ASTM D 1492-21 Wyroby chemiczne: weglowodory aromatyczne Indeks bromowy\nZakres (1,0 – 100,0) (mg Br/100g)\nMetoda miareczkowania kulometrycznego ASTM D 1492-21","categories":["other"],"row_index":103,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5ad","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Wyroby chemiczne: jednopierścieniowe węglowodory aromatyczne","methodology":"Zawartość śladowych zanieczyszczeń w jednopierścieniowych węglowodorach aromatycznych Całkowita zawartość zanieczyszczeń alifatycznych (C4 – C10) i poszczególnych jednopierścieniowych aromatycznych (C6 – C10)","parameters":[{"name":"Zakres","range":"(0,0006 – 2,5) %(m/m)"},{"name":"Czystość jednopierścieniowych węglowodorów aromatycznych"},{"name":"benzenu"},{"name":"toluenu"},{"name":"paraksylenu"},{"name":"Zakres","range":"97,60 – 99,99 %(m/m)"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość śladowych zanieczyszczeń w jednopierścieniowych węglowodorach aromatycznych Całkowita zawartość zanieczyszczeń alifatycznych (C4 – C10) i poszczególnych jednopierścieniowych aromatycznych (C6 – C10)\nZakres:\nZakres (0,0006 – 2,5) %(m/m)\nCzystość jednopierścieniowych węglowodorów aromatycznych\nbenzenu\ntoluenu\nparaksylenu\nZakres 97,60 – 99,99 %(m/m)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"ASTM D 7504-23","norm_bases":["ASTM D 7504-23"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby chemiczne: jednopierścieniowe węglowodory aromatyczne Zawartość śladowych zanieczyszczeń w jednopierścieniowych węglowodorach aromatycznych Całkowita zawartość zanieczyszczeń alifatycznych (C4 – C10) i poszczególnych jednopierścieniowych aromatycznych (C6 – C10)\nZakres:\nZakres (0,0006 – 2,5) %(m/m)\nCzystość jednopierścieniowych węglowodorów aromatycznych\nbenzenu\ntoluenu\nparaksylenu\nZakres 97,60 – 99,99 %(m/m)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) ASTM D 7504-23 Wyroby chemiczne: jednopierscieniowe weglowodory aromatyczne Zawartosc sladowych zanieczyszczen w jednopierscieniowych weglowodorach aromatycznych Calkowita zawartosc zanieczyszczen alifatycznych (C4 – C10) i poszczegolnych jednopierscieniowych aromatycznych (C6 – C10)\nZakres:\nZakres (0,0006 – 2,5) %(m/m)\nCzystosc jednopierscieniowych weglowodorow aromatycznych\nbenzenu\ntoluenu\nparaksylenu\nZakres 97,60 – 99,99 %(m/m)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) ASTM D 7504-23","categories":["other"],"row_index":104,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5ae","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość alkoholu metylowego","parameters":[{"name":"Zakres","range":"(0,01– 0,5) %(m/m)"}],"technique":"Metoda chromatografii gazowej z analizą warstwy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID)","techniques":["Metoda chromatografii gazowej z analizą warstwy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID)"],"computed":[],"activity":"Zawartość alkoholu metylowego\nZakres (0,01– 0,5) %(m/m)\nMetoda chromatografii gazowej z analizą warstwy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID)","reference":"PN-EN 14110:2019-05","norm_bases":["PN-EN 14110:2019-05"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Zawartość alkoholu metylowego\nZakres (0,01– 0,5) %(m/m)\nMetoda chromatografii gazowej z analizą warstwy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID) PN-EN 14110:2019-05 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Zawartosc alkoholu metylowego\nZakres (0,01– 0,5) %(m/m)\nMetoda chromatografii gazowej z analiza warstwy nadpowierzchniowej i detekcja plomieniowo-jonizacyjna (HS-GC-FID) PN-EN 14110:2019-05","categories":["petro"],"row_index":105,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5af","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: bioetanol","methodology":"Zawartość miedzi","parameters":[{"name":"Zakres","range":"(0,07 – 0,20) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)"],"computed":[],"activity":"Zawartość miedzi\nZakres (0,07 – 0,20) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","reference":"PN-EN 15488:2009","norm_bases":["PN-EN 15488:2009"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: bioetanol Zawartość miedzi\nZakres (0,07 – 0,20) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS) PN-EN 15488:2009 Paliwa ciekle: biopaliwa ciekle: bioetanol Zawartosc miedzi\nZakres (0,07 – 0,20) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z atomizacja elektrotermiczna (ETAAS) PN-EN 15488:2009","categories":["petro"],"row_index":106,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5b0","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: bioetanol","methodology":"Moc","parameters":[{"name":"Zakres","range":"(80,0 – 100,0) %(v/v)"}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"computed":[],"activity":"Moc\nZakres (80,0 – 100,0) %(v/v)\nMetoda oscylacyjna","reference":"PN-A-79528-3:2007 p. 5.2","norm_bases":["PN-A-79528-3:2007 p. 5.2"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: bioetanol Moc\nZakres (80,0 – 100,0) %(v/v)\nMetoda oscylacyjna PN-A-79528-3:2007 p. 5.2 Paliwa ciekle: biopaliwa ciekle: bioetanol Moc\nZakres (80,0 – 100,0) %(v/v)\nMetoda oscylacyjna PN-A-79528-3:2007 p. 5.2","categories":["petro"],"row_index":107,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5b1","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: bioetanol","methodology":"Wygląd","parameters":[],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Wygląd\nMetoda wizualna","reference":"PN-EN 15769:2010","norm_bases":["PN-EN 15769:2010"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: bioetanol Wygląd\nMetoda wizualna PN-EN 15769:2010 Paliwa ciekle: biopaliwa ciekle: bioetanol Wyglad\nMetoda wizualna PN-EN 15769:2010","categories":["petro"],"row_index":108,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5b2","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: bioetanol, metanol","methodology":"Gęstość w temperaturze 20°C","parameters":[{"name":"Zakres","range":"(0,780 – 0,870) g/cm3"}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"computed":[],"activity":"Gęstość w temperaturze 20°C\nZakres (0,780 – 0,870) g/cm3\nMetoda oscylacyjna","reference":"PN-EN ISO 12185:2024-08","norm_bases":["PN-EN ISO 12185:2024-08"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: bioetanol, metanol Gęstość w temperaturze 20°C\nZakres (0,780 – 0,870) g/cm3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08 Paliwa ciekle: biopaliwa ciekle: bioetanol, metanol Gestosc w temperaturze 20°C\nZakres (0,780 – 0,870) g/cm3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08","categories":["petro"],"row_index":109,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5b3","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, biopaliwa ciekłe: FAME","methodology":"Pochodna liczby cetanowej","parameters":[{"name":"Zakres","range":"50,0 – 60,0"}],"technique":"Metoda z komorą spalania","techniques":["Metoda z komorą spalania"],"computed":[],"activity":"Pochodna liczby cetanowej\nZakres 50,0 – 60,0\nMetoda z komorą spalania","reference":"PN-EN 16715:2015-09","norm_bases":["PN-EN 16715:2015-09"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, biopaliwa ciekłe: FAME Pochodna liczby cetanowej\nZakres 50,0 – 60,0\nMetoda z komorą spalania PN-EN 16715:2015-09 Paliwa ciekle: olej napedowy, biopaliwa ciekle: FAME Pochodna liczby cetanowej\nZakres 50,0 – 60,0\nMetoda z komora spalania PN-EN 16715:2015-09","categories":["petro"],"row_index":110,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5b4","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: bioetanol, benzyna silnikowa z bioetanolem","methodology":"Zawartość siarki","parameters":[{"name":"Zakres","range":"(5,0 – 20,0)mg/kg"}],"technique":"Metoda fluorescencji w nadfiolecie","techniques":["Metoda fluorescencji w nadfiolecie"],"computed":[],"activity":"Zawartość siarki\nZakres (5,0 – 20,0)mg/kg\nMetoda fluorescencji w nadfiolecie","reference":"PN-EN 15486:2009","norm_bases":["PN-EN 15486:2009"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: bioetanol, benzyna silnikowa z bioetanolem Zawartość siarki\nZakres (5,0 – 20,0)mg/kg\nMetoda fluorescencji w nadfiolecie PN-EN 15486:2009 Paliwa ciekle: biopaliwa ciekle: bioetanol, benzyna silnikowa z bioetanolem Zawartosc siarki\nZakres (5,0 – 20,0)mg/kg\nMetoda fluorescencji w nadfiolecie PN-EN 15486:2009","categories":["petro"],"row_index":111,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5b5","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: lekki olej opałowy","methodology":"Zawartość butoksybenzenu (eteru n-butylofenylowego (BPE))","parameters":[{"name":"Zakres","range":"(0,05 – 20,00) mg/l"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrii mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrii mas (GC-MS)"],"computed":[],"activity":"Zawartość butoksybenzenu (eteru n-butylofenylowego (BPE))\nZakres (0,05 – 20,00) mg/l\nMetoda chromatografii gazowej z detekcją spektrometrii mas (GC-MS)","reference":"ILIADe 606:2024 Procedura B","norm_bases":["ILIADe 606:2024 Procedura B"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: lekki olej opałowy Zawartość butoksybenzenu (eteru n-butylofenylowego (BPE))\nZakres (0,05 – 20,00) mg/l\nMetoda chromatografii gazowej z detekcją spektrometrii mas (GC-MS) ILIADe 606:2024 Procedura B Paliwa ciekle: lekki olej opalowy Zawartosc butoksybenzenu (eteru n-butylofenylowego (BPE))\nZakres (0,05 – 20,00) mg/l\nMetoda chromatografii gazowej z detekcja spektrometrii mas (GC-MS) ILIADe 606:2024 Procedura B","categories":["petro"],"row_index":112,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5b6","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ropa naftowa","methodology":"Zawartość chlorków organicznych we frakcji wrzącej do 204°C","parameters":[{"name":"Zakres","range":"(1 –50) mg/kg"},{"name":"Zawartość chlorków organicznych (z obliczeń)"}],"technique":"Metoda miareczkowania mikrokulometrycznego","techniques":["Metoda miareczkowania mikrokulometrycznego"],"computed":[],"activity":"Zawartość chlorków organicznych we frakcji wrzącej do 204°C\nZakres:\nZakres (1 –50) mg/kg\nZawartość chlorków organicznych (z obliczeń)\nMetoda miareczkowania mikrokulometrycznego","reference":"ASTM D 4929-22 metoda B","norm_bases":["ASTM D 4929-22 metoda B"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ropa naftowa Zawartość chlorków organicznych we frakcji wrzącej do 204°C\nZakres:\nZakres (1 –50) mg/kg\nZawartość chlorków organicznych (z obliczeń)\nMetoda miareczkowania mikrokulometrycznego ASTM D 4929-22 metoda B Ropa naftowa Zawartosc chlorkow organicznych we frakcji wrzacej do 204°C\nZakres:\nZakres (1 –50) mg/kg\nZawartosc chlorkow organicznych (z obliczen)\nMetoda miareczkowania mikrokulometrycznego ASTM D 4929-22 metoda B","categories":["petro"],"row_index":113,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5b7","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie rtęci","parameters":[{"name":"Zakres","range":"(0,010 – 10,0) μg/l"}],"technique":"Metoda fluorescencyjnej spektrometrii atomowej z generowaniem zimnych par (CVAFS)","techniques":["Metoda fluorescencyjnej spektrometrii atomowej z generowaniem zimnych par (CVAFS)"],"computed":[],"activity":"Stężenie rtęci\nZakres (0,010 – 10,0) μg/l\nMetoda fluorescencyjnej spektrometrii atomowej z generowaniem zimnych par (CVAFS)","reference":"PN-EN ISO 17852:2009","norm_bases":["PN-EN ISO 17852:2009"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie rtęci\nZakres (0,010 – 10,0) μg/l\nMetoda fluorescencyjnej spektrometrii atomowej z generowaniem zimnych par (CVAFS) PN-EN ISO 17852:2009 Woda, scieki Stezenie rteci\nZakres (0,010 – 10,0) μg/l\nMetoda fluorescencyjnej spektrometrii atomowej z generowaniem zimnych par (CVAFS) PN-EN ISO 17852:2009","categories":["water"],"row_index":114,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5b8","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, Ropa naftowa","methodology":"Skład frakcyjny","parameters":[{"name":"Zakres","range":"(50 – 380) °C"}],"technique":"Metoda destylacyjna","techniques":["Metoda destylacyjna"],"computed":[],"activity":"Skład frakcyjny\nZakres (50 – 380) °C\nMetoda destylacyjna","reference":"PN-EN ISO 3405:2019-05 z wyłączeniem pkt 9 | ASTM D 86-23aɛ2","norm_bases":["PN-EN ISO 3405:2019-05 z wyłączeniem pkt 9","ASTM D 86-23aɛ2"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, Ropa naftowa Skład frakcyjny\nZakres (50 – 380) °C\nMetoda destylacyjna PN-EN ISO 3405:2019-05 z wyłączeniem pkt 9 | ASTM D 86-23aɛ2 Paliwa ciekle: olej napedowy, olej opalowy lekki, Ropa naftowa Sklad frakcyjny\nZakres (50 – 380) °C\nMetoda destylacyjna PN-EN ISO 3405:2019-05 z wylaczeniem pkt 9 | ASTM D 86-23aɛ2","categories":["petro"],"row_index":115,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5b9","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: olej napędowy z FAME","methodology":"Skład frakcyjny","parameters":[{"name":"Zakres","range":"(50 – 380) °C"}],"technique":"Metoda destylacyjna","techniques":["Metoda destylacyjna"],"computed":[],"activity":"Skład frakcyjny\nZakres (50 – 380) °C\nMetoda destylacyjna","reference":"PN-EN ISO 3405:2019-05 z wyłączeniem pkt 9","norm_bases":["PN-EN ISO 3405:2019-05 z wyłączeniem pkt 9"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: olej napędowy z FAME Skład frakcyjny\nZakres (50 – 380) °C\nMetoda destylacyjna PN-EN ISO 3405:2019-05 z wyłączeniem pkt 9 Paliwa ciekle: biopaliwa ciekle: olej napedowy z FAME Sklad frakcyjny\nZakres (50 – 380) °C\nMetoda destylacyjna PN-EN ISO 3405:2019-05 z wylaczeniem pkt 9","categories":["petro"],"row_index":116,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5ba","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, biopaliwa ciekłe: olej napędowy z FAME","methodology":"Indeks cetanowy (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Indeks cetanowy (z obliczeń)","reference":"PN-EN ISO 4264:2018-08","norm_bases":["PN-EN ISO 4264:2018-08"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, biopaliwa ciekłe: olej napędowy z FAME Indeks cetanowy (z obliczeń) PN-EN ISO 4264:2018-08 Paliwa ciekle: olej napedowy, olej opalowy lekki, biopaliwa ciekle: olej napedowy z FAME Indeks cetanowy (z obliczen) PN-EN ISO 4264:2018-08","categories":["petro"],"row_index":117,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5bb","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki, olej opałowy ciężki, biopaliwa ciekłe: olej napędowy z FAME, estry metylowe kwasów tłuszczowych (FAME), Inne przetwory naftowe: olej popirolityczny, Ropa naftowa","methodology":"Gęstość w temperaturze 15°C","parameters":[{"name":"Zakres","range":"(630 – 1100) kg/m3"}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"computed":[],"activity":"Gęstość w temperaturze 15°C\nZakres (630 – 1100) kg/m3\nMetoda oscylacyjna","reference":"PN-EN ISO 12185:2024-08","norm_bases":["PN-EN ISO 12185:2024-08"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki, olej opałowy ciężki, biopaliwa ciekłe: olej napędowy z FAME, estry metylowe kwasów tłuszczowych (FAME), Inne przetwory naftowe: olej popirolityczny, Ropa naftowa Gęstość w temperaturze 15°C\nZakres (630 – 1100) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08 Paliwa ciekle: benzyna bezolowiowa, olej napedowy, olej opalowy lekki, olej opalowy ciezki, biopaliwa ciekle: olej napedowy z FAME, estry metylowe kwasow tluszczowych (FAME), Inne przetwory naftowe: olej popirolityczny, Ropa naftowa Gestosc w temperaturze 15°C\nZakres (630 – 1100) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08","categories":["petro"],"row_index":118,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5bc","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, olej opałowy ciężki, biopaliwa ciekłe: olej napędowy z FAME, estry metylowe kwasów tłuszczowych (FAME), Inne przetwory naftowe: pozostałość próżniowa (gudron), frakcje i/lub produkty naftowe o temperaturze wrzenia 15°C - 500°C, Ropa naftowa","methodology":"Gęstość w temperaturze 15°C","parameters":[{"name":"Zakres","range":"(646 – 1050) kg/m3"}],"technique":"Metoda areometryczna","techniques":["Metoda areometryczna"],"computed":[],"activity":"Gęstość w temperaturze 15°C\nZakres (646 – 1050) kg/m3\nMetoda areometryczna","reference":"PN-EN ISO 3675:2004","norm_bases":["PN-EN ISO 3675:2004"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, olej opałowy ciężki, biopaliwa ciekłe: olej napędowy z FAME, estry metylowe kwasów tłuszczowych (FAME), Inne przetwory naftowe: pozostałość próżniowa (gudron), frakcje i/lub produkty naftowe o temperaturze wrzenia 15°C - 500°C, Ropa naftowa Gęstość w temperaturze 15°C\nZakres (646 – 1050) kg/m3\nMetoda areometryczna PN-EN ISO 3675:2004 Paliwa ciekle: olej napedowy, olej opalowy lekki, olej opalowy ciezki, biopaliwa ciekle: olej napedowy z FAME, estry metylowe kwasow tluszczowych (FAME), Inne przetwory naftowe: pozostalosc prozniowa (gudron), frakcje i/lub produkty naftowe o temperaturze wrzenia 15°C - 500°C, Ropa naftowa Gestosc w temperaturze 15°C\nZakres (646 – 1050) kg/m3\nMetoda areometryczna PN-EN ISO 3675:2004","categories":["petro"],"row_index":119,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5bd","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, olej opałowy ciężki, biopaliwa ciekłe: olej napędowy z FAME, Inne przetwory naftowe: frakcje i/lub produkty naftowe o temperaturze wrzenia 20°C - 550°C, asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe","methodology":"Temperatura zapłonu","parameters":[{"name":"Zakres","range":"(40 – 220) °C"}],"technique":"Metoda zamkniętego tygla Pensky’ego-Martensa","techniques":["Metoda zamkniętego tygla Pensky’ego-Martensa"],"computed":[],"activity":"Temperatura zapłonu\nZakres (40 – 220) °C\nMetoda zamkniętego tygla Pensky’ego-Martensa","reference":"PN-EN ISO 2719:2016-08+A1:2021-06","norm_bases":["PN-EN ISO 2719:2016-08+A1:2021-06"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, olej opałowy ciężki, biopaliwa ciekłe: olej napędowy z FAME, Inne przetwory naftowe: frakcje i/lub produkty naftowe o temperaturze wrzenia 20°C - 550°C, asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe Temperatura zapłonu\nZakres (40 – 220) °C\nMetoda zamkniętego tygla Pensky’ego-Martensa PN-EN ISO 2719:2016-08+A1:2021-06 Paliwa ciekle: olej napedowy, olej opalowy lekki, olej opalowy ciezki, biopaliwa ciekle: olej napedowy z FAME, Inne przetwory naftowe: frakcje i/lub produkty naftowe o temperaturze wrzenia 20°C - 550°C, asfalty drogowe, asfalty przemyslowe i wyroby asfaltowe Temperatura zaplonu\nZakres (40 – 220) °C\nMetoda zamknietego tygla Pensky’ego-Martensa PN-EN ISO 2719:2016-08+A1:2021-06","categories":["petro"],"row_index":120,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5be","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki, olej opałowy ciężki, paliwo żeglugowe, Inne przetwory naftowe: pozostałość próżniowa (gudron), Ropa naftowa","methodology":"Zawartość siarki","parameters":[{"name":"Zakres","range":"(0,03 – 5,00) %(m/m)"}],"technique":"Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii","techniques":["Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii"],"computed":[],"activity":"Zawartość siarki\nZakres (0,03 – 5,00) %(m/m)\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii","reference":"PN-EN ISO 8754:2007+Ap1:2014-02","norm_bases":["PN-EN ISO 8754:2007+Ap1:2014-02"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki, olej opałowy ciężki, paliwo żeglugowe, Inne przetwory naftowe: pozostałość próżniowa (gudron), Ropa naftowa Zawartość siarki\nZakres (0,03 – 5,00) %(m/m)\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii PN-EN ISO 8754:2007+Ap1:2014-02 Paliwa ciekle: benzyna bezolowiowa, olej napedowy, olej opalowy lekki, olej opalowy ciezki, paliwo zeglugowe, Inne przetwory naftowe: pozostalosc prozniowa (gudron), Ropa naftowa Zawartosc siarki\nZakres (0,03 – 5,00) %(m/m)\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersja energii PN-EN ISO 8754:2007+Ap1:2014-02","categories":["petro"],"row_index":121,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5bf","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki","methodology":"Zawartość barwnika Solvent Red 164","parameters":[{"name":"Zakres","range":"(1,0 – 15,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość barwnika Solvent Red 164\nZakres (1,0 – 15,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-C-04426:2013-07 Metoda B","norm_bases":["PN-C-04426:2013-07 Metoda B"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki Zawartość barwnika Solvent Red 164\nZakres (1,0 – 15,0) mg/l\nMetoda spektrofotometryczna PN-C-04426:2013-07 Metoda B Paliwa ciekle: olej napedowy, olej opalowy lekki Zawartosc barwnika Solvent Red 164\nZakres (1,0 – 15,0) mg/l\nMetoda spektrofotometryczna PN-C-04426:2013-07 Metoda B","categories":["petro"],"row_index":122,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5c0","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki","methodology":"Zawartość barwnika Solvent Red 19","parameters":[{"name":"Zakres","range":"(1,0 – 15,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość barwnika Solvent Red 19\nZakres (1,0 – 15,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-C-04426:2013-07 Metoda A","norm_bases":["PN-C-04426:2013-07 Metoda A"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki Zawartość barwnika Solvent Red 19\nZakres (1,0 – 15,0) mg/l\nMetoda spektrofotometryczna PN-C-04426:2013-07 Metoda A Paliwa ciekle: olej napedowy, olej opalowy lekki Zawartosc barwnika Solvent Red 19\nZakres (1,0 – 15,0) mg/l\nMetoda spektrofotometryczna PN-C-04426:2013-07 Metoda A","categories":["petro"],"row_index":123,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5c1","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, biopaliwa ciekłe: olej napędowy z FAME","methodology":"Stabilność oksydacyjna","parameters":[{"name":"Zakres","range":"(3 – 100) g/m3"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stabilność oksydacyjna\nZakres (3 – 100) g/m3\nMetoda wagowa","reference":"PN- EN ISO 12205:2011","norm_bases":["PN- EN ISO 12205:2011"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, biopaliwa ciekłe: olej napędowy z FAME Stabilność oksydacyjna\nZakres (3 – 100) g/m3\nMetoda wagowa PN- EN ISO 12205:2011 Paliwa ciekle: olej napedowy, biopaliwa ciekle: olej napedowy z FAME Stabilnosc oksydacyjna\nZakres (3 – 100) g/m3\nMetoda wagowa PN- EN ISO 12205:2011","categories":["petro"],"row_index":124,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5c2","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, biopaliwa ciekłe: olej napędowy z FAME","methodology":"Smarność","parameters":[{"name":"Zakres","range":"(180 – 650) μm"}],"technique":"Metoda HFRR","techniques":["Metoda HFRR"],"computed":[],"activity":"Smarność\nZakres (180 – 650) μm\nMetoda HFRR","reference":"PN-EN ISO 12156-1:2024-02","norm_bases":["PN-EN ISO 12156-1:2024-02"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, biopaliwa ciekłe: olej napędowy z FAME Smarność\nZakres (180 – 650) μm\nMetoda HFRR PN-EN ISO 12156-1:2024-02 Paliwa ciekle: olej napedowy, biopaliwa ciekle: olej napedowy z FAME Smarnosc\nZakres (180 – 650) μm\nMetoda HFRR PN-EN ISO 12156-1:2024-02","categories":["petro"],"row_index":125,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5c3","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Inne przetwory naftowe: asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe","methodology":"Penetracja","parameters":[{"name":"Zakres","range":"(20 – 330) * 0,1 mm"}],"technique":"Metoda penetracji igłą","techniques":["Metoda penetracji igłą"],"computed":[],"activity":"Penetracja\nZakres (20 – 330) * 0,1 mm\nMetoda penetracji igłą","reference":"PN-EN 1426:2025-02","norm_bases":["PN-EN 1426:2025-02"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Inne przetwory naftowe: asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe Penetracja\nZakres (20 – 330) * 0,1 mm\nMetoda penetracji igłą PN-EN 1426:2025-02 Inne przetwory naftowe: asfalty drogowe, asfalty przemyslowe i wyroby asfaltowe Penetracja\nZakres (20 – 330) * 0,1 mm\nMetoda penetracji igla PN-EN 1426:2025-02","categories":["other"],"row_index":126,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5c4","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Inne przetwory naftowe: asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe","methodology":"Temperatura mięknienia","parameters":[{"name":"Zakres","range":"(30 – 110) °C"}],"technique":"Metoda Pierścień i Kula","techniques":["Metoda Pierścień i Kula"],"computed":[],"activity":"Temperatura mięknienia\nZakres (30 – 110) °C\nMetoda Pierścień i Kula","reference":"PN-EN 1427:2015-08","norm_bases":["PN-EN 1427:2015-08"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Inne przetwory naftowe: asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe Temperatura mięknienia\nZakres (30 – 110) °C\nMetoda Pierścień i Kula PN-EN 1427:2015-08 Inne przetwory naftowe: asfalty drogowe, asfalty przemyslowe i wyroby asfaltowe Temperatura mieknienia\nZakres (30 – 110) °C\nMetoda Pierscien i Kula PN-EN 1427:2015-08","categories":["other"],"row_index":127,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5c5","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Inne przetwory naftowe: asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe","methodology":"Temperatura łamliwości w ujemnych temperaturach","parameters":[{"name":"[0","range":"(-30)] °C"}],"technique":"Metoda Fraassa","techniques":["Metoda Fraassa"],"computed":[],"activity":"Temperatura łamliwości w ujemnych temperaturach\n[0 (-30)] °C\nMetoda Fraassa","reference":"PN-EN 12593:2015-08","norm_bases":["PN-EN 12593:2015-08"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Inne przetwory naftowe: asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe Temperatura łamliwości w ujemnych temperaturach\n[0 (-30)] °C\nMetoda Fraassa PN-EN 12593:2015-08 Inne przetwory naftowe: asfalty drogowe, asfalty przemyslowe i wyroby asfaltowe Temperatura lamliwosci w ujemnych temperaturach\n[0 (-30)] °C\nMetoda Fraassa PN-EN 12593:2015-08","categories":["other"],"row_index":128,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5c6","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Inne przetwory naftowe: asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe","methodology":"Zawartość parafiny","parameters":[{"name":"Zakres","range":"(1,0 – 3,5) %(m/m)"}],"technique":"Metoda destylacyjna","techniques":["Metoda destylacyjna"],"computed":[],"activity":"Zawartość parafiny\nZakres (1,0 – 3,5) %(m/m)\nMetoda destylacyjna","reference":"PN-EN 12606-1:2015-08","norm_bases":["PN-EN 12606-1:2015-08"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Inne przetwory naftowe: asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe Zawartość parafiny\nZakres (1,0 – 3,5) %(m/m)\nMetoda destylacyjna PN-EN 12606-1:2015-08 Inne przetwory naftowe: asfalty drogowe, asfalty przemyslowe i wyroby asfaltowe Zawartosc parafiny\nZakres (1,0 – 3,5) %(m/m)\nMetoda destylacyjna PN-EN 12606-1:2015-08","categories":["other"],"row_index":129,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5c7","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Inne przetwory naftowe: asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe","methodology":"Rozpuszczalność","parameters":[{"name":"Zakres","range":"do 100,00 %(m/m)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Rozpuszczalność\nZakres do 100,00 %(m/m)\nMetoda wagowa","reference":"PN-EN 12592:2014-12","norm_bases":["PN-EN 12592:2014-12"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Inne przetwory naftowe: asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe Rozpuszczalność\nZakres do 100,00 %(m/m)\nMetoda wagowa PN-EN 12592:2014-12 Inne przetwory naftowe: asfalty drogowe, asfalty przemyslowe i wyroby asfaltowe Rozpuszczalnosc\nZakres do 100,00 %(m/m)\nMetoda wagowa PN-EN 12592:2014-12","categories":["other"],"row_index":130,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5c8","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Inne przetwory naftowe: asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe","methodology":"Odporność na starzenie pod wpływem ciepła i powietrza","parameters":[{"name":"procentowa zmiana masy [(-0,20)","range":"(+0,20)] %(m/m)"},{"name":"Procent pozostałej penetracji w temperaturze 25 °C ( z obliczeń) Zmiana temperatury mięknienia pierścień i kula (w °C) (z obliczeń)"}],"technique":"Metoda RTFOT","techniques":["Metoda RTFOT"],"computed":[],"activity":"Odporność na starzenie pod wpływem ciepła i powietrza\nZakres:\nprocentowa zmiana masy [(-0,20) (+0,20)] %(m/m)\nProcent pozostałej penetracji w temperaturze 25 °C ( z obliczeń) Zmiana temperatury mięknienia pierścień i kula (w °C) (z obliczeń)\nMetoda RTFOT","reference":"PN-EN 12607-1:2025-02","norm_bases":["PN-EN 12607-1:2025-02"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Inne przetwory naftowe: asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe Odporność na starzenie pod wpływem ciepła i powietrza\nZakres:\nprocentowa zmiana masy [(-0,20) (+0,20)] %(m/m)\nProcent pozostałej penetracji w temperaturze 25 °C ( z obliczeń) Zmiana temperatury mięknienia pierścień i kula (w °C) (z obliczeń)\nMetoda RTFOT PN-EN 12607-1:2025-02 Inne przetwory naftowe: asfalty drogowe, asfalty przemyslowe i wyroby asfaltowe Odpornosc na starzenie pod wplywem ciepla i powietrza\nZakres:\nprocentowa zmiana masy [(-0,20) (+0,20)] %(m/m)\nProcent pozostalej penetracji w temperaturze 25 °C ( z obliczen) Zmiana temperatury mieknienia pierscien i kula (w °C) (z obliczen)\nMetoda RTFOT PN-EN 12607-1:2025-02","categories":["other"],"row_index":131,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5c9","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Inne przetwory naftowe: asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe","methodology":"Odporność na starzenie pod wpływem ciepła i powietrza","parameters":[{"name":"Zakres","range":"procentowa zmiana masy"},{"name":"[(-1,5)","range":"(+2,0)] %(m/m)"}],"technique":"Metoda TFOT","techniques":["Metoda TFOT"],"computed":[],"activity":"Odporność na starzenie pod wpływem ciepła i powietrza\nZakres:\nZakres procentowa zmiana masy\n[(-1,5) (+2,0)] %(m/m)\nMetoda TFOT","reference":"PN-EN 12607-2:2014-12","norm_bases":["PN-EN 12607-2:2014-12"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Inne przetwory naftowe: asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe Odporność na starzenie pod wpływem ciepła i powietrza\nZakres:\nZakres procentowa zmiana masy\n[(-1,5) (+2,0)] %(m/m)\nMetoda TFOT PN-EN 12607-2:2014-12 Inne przetwory naftowe: asfalty drogowe, asfalty przemyslowe i wyroby asfaltowe Odpornosc na starzenie pod wplywem ciepla i powietrza\nZakres:\nZakres procentowa zmiana masy\n[(-1,5) (+2,0)] %(m/m)\nMetoda TFOT PN-EN 12607-2:2014-12","categories":["other"],"row_index":132,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5ca","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Inne przetwory naftowe: asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe","methodology":"Zawartość wody","parameters":[{"name":"Zakres","range":"(0 – 25,0) %(v/v) %(V/m)"}],"technique":"Metoda destylacyjna","techniques":["Metoda destylacyjna"],"computed":[],"activity":"Zawartość wody\nZakres (0 – 25,0) %(v/v) %(V/m)\nMetoda destylacyjna","reference":"ASTM D 95-23ɛ1","norm_bases":["ASTM D 95-23ɛ1"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Inne przetwory naftowe: asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe Zawartość wody\nZakres (0 – 25,0) %(v/v) %(V/m)\nMetoda destylacyjna ASTM D 95-23ɛ1 Inne przetwory naftowe: asfalty drogowe, asfalty przemyslowe i wyroby asfaltowe Zawartosc wody\nZakres (0 – 25,0) %(v/v) %(V/m)\nMetoda destylacyjna ASTM D 95-23ɛ1","categories":["water"],"row_index":133,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5cb","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Inne przetwory naftowe: asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe","methodology":"Lepkość dynamiczna w temp. 60 °C .","parameters":[{"name":"Zakres","range":"(50 – 8000) Pa s"}],"technique":"Metoda kapilarna","techniques":["Metoda kapilarna"],"computed":[],"activity":"Lepkość dynamiczna w temp. 60 °C .\nZakres (50 – 8000) Pa s\nMetoda kapilarna","reference":"PN-EN 12596:2024-01","norm_bases":["PN-EN 12596:2024-01"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Inne przetwory naftowe: asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe Lepkość dynamiczna w temp. 60 °C .\nZakres (50 – 8000) Pa s\nMetoda kapilarna PN-EN 12596:2024-01 Inne przetwory naftowe: asfalty drogowe, asfalty przemyslowe i wyroby asfaltowe Lepkosc dynamiczna w temp. 60 °C .\nZakres (50 – 8000) Pa s\nMetoda kapilarna PN-EN 12596:2024-01","categories":["other"],"row_index":134,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5cc","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Inne przetwory naftowe: asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe","methodology":"Stabilność podczas magazynowania (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stabilność podczas magazynowania (z obliczeń)","reference":"PN-EN 13399:2017-12","norm_bases":["PN-EN 13399:2017-12"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Inne przetwory naftowe: asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe Stabilność podczas magazynowania (z obliczeń) PN-EN 13399:2017-12 Inne przetwory naftowe: asfalty drogowe, asfalty przemyslowe i wyroby asfaltowe Stabilnosc podczas magazynowania (z obliczen) PN-EN 13399:2017-12","categories":["other"],"row_index":135,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5cd","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Inne przetwory naftowe: asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe","methodology":"Ubytek masy po ogrzaniu","parameters":[{"name":"Zakres","range":"(0,02 – 0,5) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Ubytek masy po ogrzaniu\nZakres (0,02 – 0,5) %\nMetoda wagowa","reference":"PN-EN 13303:2017-10","norm_bases":["PN-EN 13303:2017-10"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Inne przetwory naftowe: asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe Ubytek masy po ogrzaniu\nZakres (0,02 – 0,5) %\nMetoda wagowa PN-EN 13303:2017-10 Inne przetwory naftowe: asfalty drogowe, asfalty przemyslowe i wyroby asfaltowe Ubytek masy po ogrzaniu\nZakres (0,02 – 0,5) %\nMetoda wagowa PN-EN 13303:2017-10","categories":["other"],"row_index":136,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5ce","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Inne przetwory naftowe: asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe","methodology":"Nawrót sprężysty","parameters":[{"name":"Zakres","range":"(15 – 98) %"}],"technique":"Metoda duktylometryczna","techniques":["Metoda duktylometryczna"],"computed":[],"activity":"Nawrót sprężysty\nZakres (15 – 98) %\nMetoda duktylometryczna","reference":"PN-EN 13398:2017-12","norm_bases":["PN-EN 13398:2017-12"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Inne przetwory naftowe: asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe Nawrót sprężysty\nZakres (15 – 98) %\nMetoda duktylometryczna PN-EN 13398:2017-12 Inne przetwory naftowe: asfalty drogowe, asfalty przemyslowe i wyroby asfaltowe Nawrot sprezysty\nZakres (15 – 98) %\nMetoda duktylometryczna PN-EN 13398:2017-12","categories":["other"],"row_index":137,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5cf","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Inne przetwory naftowe: asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe","methodology":"Gęstość i gęstość względna","parameters":[{"name":"Zakres","range":"(940 – 1030) kg/m3"}],"technique":"Metoda piknometryczna","techniques":["Metoda piknometryczna"],"computed":[],"activity":"Gęstość i gęstość względna\nZakres (940 – 1030) kg/m3\nMetoda piknometryczna","reference":"PN-EN 15326+A1:2010","norm_bases":["PN-EN 15326+A1:2010"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Inne przetwory naftowe: asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe Gęstość i gęstość względna\nZakres (940 – 1030) kg/m3\nMetoda piknometryczna PN-EN 15326+A1:2010 Inne przetwory naftowe: asfalty drogowe, asfalty przemyslowe i wyroby asfaltowe Gestosc i gestosc wzgledna\nZakres (940 – 1030) kg/m3\nMetoda piknometryczna PN-EN 15326+A1:2010","categories":["other"],"row_index":138,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5d0","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Inne przetwory naftowe: asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe","methodology":"Lepkość kinematyczna w temp. 135°C","parameters":[{"name":"Zakres","range":"(20 – 2000) mm2/s"}],"technique":"Metoda kapilarna","techniques":["Metoda kapilarna"],"computed":[],"activity":"Lepkość kinematyczna w temp. 135°C\nZakres (20 – 2000) mm2/s\nMetoda kapilarna","reference":"PN-EN 12595:2024-01","norm_bases":["PN-EN 12595:2024-01"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Inne przetwory naftowe: asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe Lepkość kinematyczna w temp. 135°C\nZakres (20 – 2000) mm2/s\nMetoda kapilarna PN-EN 12595:2024-01 Inne przetwory naftowe: asfalty drogowe, asfalty przemyslowe i wyroby asfaltowe Lepkosc kinematyczna w temp. 135°C\nZakres (20 – 2000) mm2/s\nMetoda kapilarna PN-EN 12595:2024-01","categories":["other"],"row_index":139,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5d1","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Inne przetwory naftowe: asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe","methodology":"Siła rozciągania","parameters":[{"name":"Zakres","range":"(1,0 – 10,0) J/cm2"},{"name":"Energia odkształcenia (z obliczeń)"}],"technique":"Metoda duktylometryczna","techniques":["Metoda duktylometryczna"],"computed":[],"activity":"Siła rozciągania\nZakres:\nZakres (1,0 – 10,0) J/cm2\nEnergia odkształcenia (z obliczeń)\nMetoda duktylometryczna","reference":"PN-EN 13589:2018-08","norm_bases":["PN-EN 13589:2018-08"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Inne przetwory naftowe: asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe Siła rozciągania\nZakres:\nZakres (1,0 – 10,0) J/cm2\nEnergia odkształcenia (z obliczeń)\nMetoda duktylometryczna PN-EN 13589:2018-08 Inne przetwory naftowe: asfalty drogowe, asfalty przemyslowe i wyroby asfaltowe Sila rozciagania\nZakres:\nZakres (1,0 – 10,0) J/cm2\nEnergia odksztalcenia (z obliczen)\nMetoda duktylometryczna PN-EN 13589:2018-08","categories":["other"],"row_index":140,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5d2","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ropa naftowa","methodology":"Zawartość wody","parameters":[{"name":"Zakres","range":"(0 – 1,0) %(v/v)"}],"technique":"Metoda destylacyjna","techniques":["Metoda destylacyjna"],"computed":[],"activity":"Zawartość wody\nZakres (0 – 1,0) %(v/v)\nMetoda destylacyjna","reference":"PN-EN ISO 9029:2005 | ASTM D 4006-22","norm_bases":["PN-EN ISO 9029:2005","ASTM D 4006-22"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ropa naftowa Zawartość wody\nZakres (0 – 1,0) %(v/v)\nMetoda destylacyjna PN-EN ISO 9029:2005 | ASTM D 4006-22 Ropa naftowa Zawartosc wody\nZakres (0 – 1,0) %(v/v)\nMetoda destylacyjna PN-EN ISO 9029:2005 | ASTM D 4006-22","categories":["water","petro"],"row_index":141,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5d3","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ropa naftowa","methodology":"Gęstość","parameters":[{"name":"Zakres","range":"(750,0 – 950,0) kg/m3"}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"computed":[],"activity":"Gęstość\nZakres (750,0 – 950,0) kg/m3\nMetoda oscylacyjna","reference":"ASTM D 5002-22","norm_bases":["ASTM D 5002-22"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ropa naftowa Gęstość\nZakres (750,0 – 950,0) kg/m3\nMetoda oscylacyjna ASTM D 5002-22 Ropa naftowa Gestosc\nZakres (750,0 – 950,0) kg/m3\nMetoda oscylacyjna ASTM D 5002-22","categories":["petro"],"row_index":142,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5d4","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ropa naftowa","methodology":"Zawartość wody","parameters":[{"name":"Zakres","range":"(0,02 – 2,00) %(m/m)"}],"technique":"Metoda miareczkowania potencjometrycznego","techniques":["Metoda miareczkowania potencjometrycznego"],"computed":[],"activity":"Zawartość wody\nZakres (0,02 – 2,00) %(m/m)\nMetoda miareczkowania potencjometrycznego","reference":"ASTM D 4377-00 (2011)","norm_bases":["ASTM D 4377-00 (2011)"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ropa naftowa Zawartość wody\nZakres (0,02 – 2,00) %(m/m)\nMetoda miareczkowania potencjometrycznego ASTM D 4377-00 (2011) Ropa naftowa Zawartosc wody\nZakres (0,02 – 2,00) %(m/m)\nMetoda miareczkowania potencjometrycznego ASTM D 4377-00 (2011)","categories":["water","petro"],"row_index":143,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5d5","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ropa naftowa","methodology":"Zawartość wody","parameters":[{"name":"Zakres","range":"(0,02 – 5,00) % (m/m lub V/V)"}],"technique":"Metoda miareczkowania kulometrycznego","techniques":["Metoda miareczkowania kulometrycznego"],"computed":[],"activity":"Zawartość wody\nZakres (0,02 – 5,00) % (m/m lub V/V)\nMetoda miareczkowania kulometrycznego","reference":"ASTM D 4928-12(2018)","norm_bases":["ASTM D 4928-12(2018)"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ropa naftowa Zawartość wody\nZakres (0,02 – 5,00) % (m/m lub V/V)\nMetoda miareczkowania kulometrycznego ASTM D 4928-12(2018) Ropa naftowa Zawartosc wody\nZakres (0,02 – 5,00) % (m/m lub V/V)\nMetoda miareczkowania kulometrycznego ASTM D 4928-12(2018)","categories":["water","petro"],"row_index":144,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5d6","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ropa naftowa","methodology":"Skład frakcyjny","parameters":[{"name":"Zakres","range":"(30 – 300)°C"}],"technique":"Metoda destylacyjna","techniques":["Metoda destylacyjna"],"computed":[],"activity":"Skład frakcyjny\nZakres (30 – 300)°C\nMetoda destylacyjna","reference":"GOST 2177-99 metoda B","norm_bases":["GOST 2177-99 metoda B"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ropa naftowa Skład frakcyjny\nZakres (30 – 300)°C\nMetoda destylacyjna GOST 2177-99 metoda B Ropa naftowa Sklad frakcyjny\nZakres (30 – 300)°C\nMetoda destylacyjna GOST 2177-99 metoda B","categories":["petro"],"row_index":145,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5d7","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ropa naftowa","methodology":"Skład frakcyjny","parameters":[{"name":"[(-1)","range":"(+400)] °C"}],"technique":"Metoda destylacyjna","techniques":["Metoda destylacyjna"],"computed":[],"activity":"Skład frakcyjny\n[(-1) (+400)] °C\nMetoda destylacyjna","reference":"ASTM D 2892-25","norm_bases":["ASTM D 2892-25"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ropa naftowa Skład frakcyjny\n[(-1) (+400)] °C\nMetoda destylacyjna ASTM D 2892-25 Ropa naftowa Sklad frakcyjny\n[(-1) (+400)] °C\nMetoda destylacyjna ASTM D 2892-25","categories":["petro"],"row_index":146,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5d8","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ropa naftowa – pozostałość po destylacji wg ASTM D 2892","methodology":"Skład frakcyjny","parameters":[{"name":"Zakres","range":"(380 – 565) °C"}],"technique":"Metoda destylacyjna","techniques":["Metoda destylacyjna"],"computed":[],"activity":"Skład frakcyjny\nZakres (380 – 565) °C\nMetoda destylacyjna","reference":"ASTM D 5236-25","norm_bases":["ASTM D 5236-25"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ropa naftowa – pozostałość po destylacji wg ASTM D 2892 Skład frakcyjny\nZakres (380 – 565) °C\nMetoda destylacyjna ASTM D 5236-25 Ropa naftowa – pozostalosc po destylacji wg ASTM D 2892 Sklad frakcyjny\nZakres (380 – 565) °C\nMetoda destylacyjna ASTM D 5236-25","categories":["petro"],"row_index":147,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5d9","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe olej napędowy, olej opałowy lekki, olej opałowy ciężki, Inne przetwory naftowe: olej popirolityczny, Ropa naftowa","methodology":"Temperatura płynięcia","parameters":[{"name":"[10","range":"(-50)] °C"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Temperatura płynięcia\n[10 (-50)] °C\nMetoda optyczna","reference":"PN-EN ISO 3016:2019-06 | ASTM D 97-17b(2022)","norm_bases":["PN-EN ISO 3016:2019-06","ASTM D 97-17b(2022)"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe olej napędowy, olej opałowy lekki, olej opałowy ciężki, Inne przetwory naftowe: olej popirolityczny, Ropa naftowa Temperatura płynięcia\n[10 (-50)] °C\nMetoda optyczna PN-EN ISO 3016:2019-06 | ASTM D 97-17b(2022) Paliwa ciekle olej napedowy, olej opalowy lekki, olej opalowy ciezki, Inne przetwory naftowe: olej popirolityczny, Ropa naftowa Temperatura plyniecia\n[10 (-50)] °C\nMetoda optyczna PN-EN ISO 3016:2019-06 | ASTM D 97-17b(2022)","categories":["petro"],"row_index":148,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5da","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, olej opałowy ciężki, Inne przetwory naftowe: olej popirolityczny, pozostałość próżniowa (gudron), Ropa naftowa","methodology":"Lepkość kinematyczna w temp. 20 °C, 40 °C, 50 °C, 80 °C i 100 °C","parameters":[{"name":"Zakres","range":"(1,000 – 150,0) mm2/s"}],"technique":"Metoda kapilarna","techniques":["Metoda kapilarna"],"computed":[],"activity":"Lepkość kinematyczna w temp. 20 °C, 40 °C, 50 °C, 80 °C i 100 °C\nZakres (1,000 – 150,0) mm2/s\nMetoda kapilarna","reference":"PN-EN ISO 3104:2024-01 | ASTM D 445-24","norm_bases":["PN-EN ISO 3104:2024-01","ASTM D 445-24"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, olej opałowy ciężki, Inne przetwory naftowe: olej popirolityczny, pozostałość próżniowa (gudron), Ropa naftowa Lepkość kinematyczna w temp. 20 °C, 40 °C, 50 °C, 80 °C i 100 °C\nZakres (1,000 – 150,0) mm2/s\nMetoda kapilarna PN-EN ISO 3104:2024-01 | ASTM D 445-24 Paliwa ciekle: olej napedowy, olej opalowy lekki, olej opalowy ciezki, Inne przetwory naftowe: olej popirolityczny, pozostalosc prozniowa (gudron), Ropa naftowa Lepkosc kinematyczna w temp. 20 °C, 40 °C, 50 °C, 80 °C i 100 °C\nZakres (1,000 – 150,0) mm2/s\nMetoda kapilarna PN-EN ISO 3104:2024-01 | ASTM D 445-24","categories":["petro"],"row_index":149,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5db","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, Inne przetwory naftowe: pozostałość próżniowa (gudron), frakcje i/lub produkty naftowe o temperaturze wrzenia 20°C - 550°C, Ropa naftowa","methodology":"Pozostałość po koksowaniu","parameters":[{"name":"Zakres","range":"(0,01 – 24) %(m/m)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Pozostałość po koksowaniu\nZakres (0,01 – 24) %(m/m)\nMetoda wagowa","reference":"PN-ISO 6615:2012","norm_bases":["PN-ISO 6615:2012"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, Inne przetwory naftowe: pozostałość próżniowa (gudron), frakcje i/lub produkty naftowe o temperaturze wrzenia 20°C - 550°C, Ropa naftowa Pozostałość po koksowaniu\nZakres (0,01 – 24) %(m/m)\nMetoda wagowa PN-ISO 6615:2012 Paliwa ciekle: olej napedowy, Inne przetwory naftowe: pozostalosc prozniowa (gudron), frakcje i/lub produkty naftowe o temperaturze wrzenia 20°C - 550°C, Ropa naftowa Pozostalosc po koksowaniu\nZakres (0,01 – 24) %(m/m)\nMetoda wagowa PN-ISO 6615:2012","categories":["petro"],"row_index":150,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5dc","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, Inne przetwory naftowe: pozostałość próżniowa (gudron), Ropa naftowa","methodology":"Zawartość siarki całkowitej","parameters":[{"name":"Zakres","range":"(0,0150 – 2,00) %(m/m)"}],"technique":"Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii","techniques":["Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii"],"computed":[],"activity":"Zawartość siarki całkowitej\nZakres (0,0150 – 2,00) %(m/m)\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii","reference":"ASTM D 4294-24","norm_bases":["ASTM D 4294-24"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, Inne przetwory naftowe: pozostałość próżniowa (gudron), Ropa naftowa Zawartość siarki całkowitej\nZakres (0,0150 – 2,00) %(m/m)\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii ASTM D 4294-24 Paliwa ciekle: olej napedowy, olej opalowy lekki, Inne przetwory naftowe: pozostalosc prozniowa (gudron), Ropa naftowa Zawartosc siarki calkowitej\nZakres (0,0150 – 2,00) %(m/m)\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersja energii ASTM D 4294-24","categories":["petro"],"row_index":151,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5dd","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej opałowy ciężki, Inne przetwory naftowe: olej popirolityczny, Ropa naftowa","methodology":"Zawartość zanieczyszczeń","parameters":[{"name":"Zakres","range":"(0,01 – 0,40) %(m/m)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość zanieczyszczeń\nZakres (0,01 – 0,40) %(m/m)\nMetoda wagowa","reference":"PN-EN ISO 3735:2001 | ASTM D 473-22","norm_bases":["PN-EN ISO 3735:2001","ASTM D 473-22"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej opałowy ciężki, Inne przetwory naftowe: olej popirolityczny, Ropa naftowa Zawartość zanieczyszczeń\nZakres (0,01 – 0,40) %(m/m)\nMetoda wagowa PN-EN ISO 3735:2001 | ASTM D 473-22 Paliwa ciekle: olej opalowy ciezki, Inne przetwory naftowe: olej popirolityczny, Ropa naftowa Zawartosc zanieczyszczen\nZakres (0,01 – 0,40) %(m/m)\nMetoda wagowa PN-EN ISO 3735:2001 | ASTM D 473-22","categories":["petro"],"row_index":152,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5de","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej opałowy ciężki, Inne przetwory naftowe: olej popirolityczny, pozostałość próżniowa (gudron), frakcje i/lub produkty naftowe o temperaturze wrzenia 80°C - 550°C, asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe","methodology":"Temperatura zapłonu","parameters":[{"name":"Zakres","range":"(90 – 380) oC"}],"technique":"Metoda otwartego tygla Clevelanda","techniques":["Metoda otwartego tygla Clevelanda"],"computed":[],"activity":"Temperatura zapłonu\nZakres (90 – 380) oC\nMetoda otwartego tygla Clevelanda","reference":"PN-EN ISO 2592:2017-10","norm_bases":["PN-EN ISO 2592:2017-10"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej opałowy ciężki, Inne przetwory naftowe: olej popirolityczny, pozostałość próżniowa (gudron), frakcje i/lub produkty naftowe o temperaturze wrzenia 80°C - 550°C, asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe Temperatura zapłonu\nZakres (90 – 380) oC\nMetoda otwartego tygla Clevelanda PN-EN ISO 2592:2017-10 Paliwa ciekle: olej opalowy ciezki, Inne przetwory naftowe: olej popirolityczny, pozostalosc prozniowa (gudron), frakcje i/lub produkty naftowe o temperaturze wrzenia 80°C - 550°C, asfalty drogowe, asfalty przemyslowe i wyroby asfaltowe Temperatura zaplonu\nZakres (90 – 380) oC\nMetoda otwartego tygla Clevelanda PN-EN ISO 2592:2017-10","categories":["petro"],"row_index":153,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5df","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, biopaliwa ciekłe: olej napędowy z FAME, estry metylowe kwasów tłuszczowych (FAME), olej żeglugowy","methodology":"Zawartość siarki","parameters":[{"name":"Zakres","range":"(3,0 – 500) mg/kg"}],"technique":"Metoda fluorescencji w nadfiolecie","techniques":["Metoda fluorescencji w nadfiolecie"],"computed":[],"activity":"Zawartość siarki\nZakres (3,0 – 500) mg/kg\nMetoda fluorescencji w nadfiolecie","reference":"PN-EN ISO 20846:2020-03","norm_bases":["PN-EN ISO 20846:2020-03"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, biopaliwa ciekłe: olej napędowy z FAME, estry metylowe kwasów tłuszczowych (FAME), olej żeglugowy Zawartość siarki\nZakres (3,0 – 500) mg/kg\nMetoda fluorescencji w nadfiolecie PN-EN ISO 20846:2020-03 Paliwa ciekle: olej napedowy, olej opalowy lekki, biopaliwa ciekle: olej napedowy z FAME, estry metylowe kwasow tluszczowych (FAME), olej zeglugowy Zawartosc siarki\nZakres (3,0 – 500) mg/kg\nMetoda fluorescencji w nadfiolecie PN-EN ISO 20846:2020-03","categories":["petro"],"row_index":154,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5e0","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, olej opałowy ciężki, biopaliwa ciekłe: olej napędowy z FAME, estry metylowe kwasów tłuszczowych (FAME), Inne przetwory naftowe: pozostałość próżniowa (gudron), frakcje i/lub produkty naftowe o temperaturze wrzenia 20°C - 550°C, Ropa naftowa","methodology":"Pozostałość po koksowaniu","parameters":[{"name":"Zakres","range":"(0,01 – 24,00) %(m/m)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Pozostałość po koksowaniu\nZakres (0,01 – 24,00) %(m/m)\nMetoda wagowa","reference":"PN-EN ISO 10370:2014-12","norm_bases":["PN-EN ISO 10370:2014-12"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, olej opałowy ciężki, biopaliwa ciekłe: olej napędowy z FAME, estry metylowe kwasów tłuszczowych (FAME), Inne przetwory naftowe: pozostałość próżniowa (gudron), frakcje i/lub produkty naftowe o temperaturze wrzenia 20°C - 550°C, Ropa naftowa Pozostałość po koksowaniu\nZakres (0,01 – 24,00) %(m/m)\nMetoda wagowa PN-EN ISO 10370:2014-12 Paliwa ciekle: olej napedowy, olej opalowy lekki, olej opalowy ciezki, biopaliwa ciekle: olej napedowy z FAME, estry metylowe kwasow tluszczowych (FAME), Inne przetwory naftowe: pozostalosc prozniowa (gudron), frakcje i/lub produkty naftowe o temperaturze wrzenia 20°C - 550°C, Ropa naftowa Pozostalosc po koksowaniu\nZakres (0,01 – 24,00) %(m/m)\nMetoda wagowa PN-EN ISO 10370:2014-12","categories":["petro"],"row_index":155,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5e1","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, olej opałowy ciężki, biopaliwa ciekłe: olej napędowy z FAME, Inne przetwory naftowe: olej popirolityczny, pozostałość próżniowa (gudron), Ropa naftowa","methodology":"Pozostałość po spopieleniu","parameters":[{"name":"Zakres","range":"(0,001 – 0,180) %(m/m)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Pozostałość po spopieleniu\nZakres (0,001 – 0,180) %(m/m)\nMetoda wagowa","reference":"PN-EN ISO 6245:2008","norm_bases":["PN-EN ISO 6245:2008"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, olej opałowy ciężki, biopaliwa ciekłe: olej napędowy z FAME, Inne przetwory naftowe: olej popirolityczny, pozostałość próżniowa (gudron), Ropa naftowa Pozostałość po spopieleniu\nZakres (0,001 – 0,180) %(m/m)\nMetoda wagowa PN-EN ISO 6245:2008 Paliwa ciekle: olej napedowy, olej opalowy lekki, olej opalowy ciezki, biopaliwa ciekle: olej napedowy z FAME, Inne przetwory naftowe: olej popirolityczny, pozostalosc prozniowa (gudron), Ropa naftowa Pozostalosc po spopieleniu\nZakres (0,001 – 0,180) %(m/m)\nMetoda wagowa PN-EN ISO 6245:2008","categories":["petro"],"row_index":156,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5e2","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, biopaliwa ciekłe: olej napędowy z FAME, estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość wody","parameters":[{"name":"Zakres","range":"(30 – 1000) mg/kg"},{"name":"Zakres","range":"(0,003 – 0,100) %(m/m)"}],"technique":"Metoda miareczkowania kulometrycznego","techniques":["Metoda miareczkowania kulometrycznego"],"computed":[],"activity":"Zawartość wody\nZakres:\nZakres (30 – 1000) mg/kg\nZakres (0,003 – 0,100) %(m/m)\nMetoda miareczkowania kulometrycznego","reference":"PN-EN ISO 12937:2005+Ap1:2021-11","norm_bases":["PN-EN ISO 12937:2005+Ap1:2021-11"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, biopaliwa ciekłe: olej napędowy z FAME, estry metylowe kwasów tłuszczowych (FAME) Zawartość wody\nZakres:\nZakres (30 – 1000) mg/kg\nZakres (0,003 – 0,100) %(m/m)\nMetoda miareczkowania kulometrycznego PN-EN ISO 12937:2005+Ap1:2021-11 Paliwa ciekle: olej napedowy, olej opalowy lekki, biopaliwa ciekle: olej napedowy z FAME, estry metylowe kwasow tluszczowych (FAME) Zawartosc wody\nZakres:\nZakres (30 – 1000) mg/kg\nZakres (0,003 – 0,100) %(m/m)\nMetoda miareczkowania kulometrycznego PN-EN ISO 12937:2005+Ap1:2021-11","categories":["petro","water"],"row_index":157,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5e3","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, biopaliwa ciekłe: olej napędowy z FAME, estry metylowe kwasów tłuszczowych (FAME)","methodology":"Temperatura mętnienia","parameters":[{"name":"[10","range":"(- 41)] oC"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Temperatura mętnienia\n[10 (- 41)] oC\nMetoda wizualna","reference":"PN-EN ISO 3015:2019-06","norm_bases":["PN-EN ISO 3015:2019-06"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, biopaliwa ciekłe: olej napędowy z FAME, estry metylowe kwasów tłuszczowych (FAME) Temperatura mętnienia\n[10 (- 41)] oC\nMetoda wizualna PN-EN ISO 3015:2019-06 Paliwa ciekle: olej napedowy, olej opalowy lekki, biopaliwa ciekle: olej napedowy z FAME, estry metylowe kwasow tluszczowych (FAME) Temperatura metnienia\n[10 (- 41)] oC\nMetoda wizualna PN-EN ISO 3015:2019-06","categories":["petro"],"row_index":158,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5e4","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, biopaliwa ciekłe: olej napędowy z FAME, estry metylowe kwasów tłuszczowych (FAME)","methodology":"Działanie korodujące na miedź","parameters":[{"name":"Zakres","range":"1a – 4c (skala)"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Działanie korodujące na miedź\nZakres 1a – 4c (skala)\nMetoda wizualna","reference":"PN-EN ISO 2160:2004","norm_bases":["PN-EN ISO 2160:2004"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, biopaliwa ciekłe: olej napędowy z FAME, estry metylowe kwasów tłuszczowych (FAME) Działanie korodujące na miedź\nZakres 1a – 4c (skala)\nMetoda wizualna PN-EN ISO 2160:2004 Paliwa ciekle: olej napedowy, olej opalowy lekki, biopaliwa ciekle: olej napedowy z FAME, estry metylowe kwasow tluszczowych (FAME) Dzialanie korodujace na miedz\nZakres 1a – 4c (skala)\nMetoda wizualna PN-EN ISO 2160:2004","categories":["petro","materials"],"row_index":159,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5e5","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, biopaliwa ciekłe: olej napędowy z FAME, estry metylowe kwasów tłuszczowych (FAME)","methodology":"Temperatura zablokowania zimnego filtru","parameters":[{"name":"[5","range":"(- 45)] oC"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Temperatura zablokowania zimnego filtru\n[5 (- 45)] oC\nMetoda optyczna","reference":"PN-EN 116:2015-09","norm_bases":["PN-EN 116:2015-09"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, biopaliwa ciekłe: olej napędowy z FAME, estry metylowe kwasów tłuszczowych (FAME) Temperatura zablokowania zimnego filtru\n[5 (- 45)] oC\nMetoda optyczna PN-EN 116:2015-09 Paliwa ciekle: olej napedowy, olej opalowy lekki, biopaliwa ciekle: olej napedowy z FAME, estry metylowe kwasow tluszczowych (FAME) Temperatura zablokowania zimnego filtru\n[5 (- 45)] oC\nMetoda optyczna PN-EN 116:2015-09","categories":["petro"],"row_index":160,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5e6","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, biopaliwa ciekłe: olej napędowy z FAME","methodology":"Zawartość zanieczyszczeń","parameters":[{"name":"Zakres","range":"(12,0 – 26,0) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość zanieczyszczeń\nZakres (12,0 – 26,0) mg/kg\nMetoda wagowa","reference":"PN-EN 12662-1:2024-11","norm_bases":["PN-EN 12662-1:2024-11"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, biopaliwa ciekłe: olej napędowy z FAME Zawartość zanieczyszczeń\nZakres (12,0 – 26,0) mg/kg\nMetoda wagowa PN-EN 12662-1:2024-11 Paliwa ciekle: olej napedowy, olej opalowy lekki, biopaliwa ciekle: olej napedowy z FAME Zawartosc zanieczyszczen\nZakres (12,0 – 26,0) mg/kg\nMetoda wagowa PN-EN 12662-1:2024-11","categories":["petro"],"row_index":161,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5e7","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość zanieczyszczeń","parameters":[{"name":"Zakres","range":"(5,0 – 27,0) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość zanieczyszczeń\nZakres (5,0 – 27,0) mg/kg\nMetoda wagowa","reference":"PN-EN 12662-2:2024-11","norm_bases":["PN-EN 12662-2:2024-11"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Zawartość zanieczyszczeń\nZakres (5,0 – 27,0) mg/kg\nMetoda wagowa PN-EN 12662-2:2024-11 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Zawartosc zanieczyszczen\nZakres (5,0 – 27,0) mg/kg\nMetoda wagowa PN-EN 12662-2:2024-11","categories":["petro"],"row_index":162,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5e8","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej opałowy lekki, olej opałowy ciężki, Inne przetwory naftowe: pozostałość próżniowa (gudron)","methodology":"Ciepło spalania","parameters":[{"name":"Zakres","range":"(26 500 – 46 300) kJ/kg"},{"name":"Wartość opałowa (z obliczeń)"}],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna"],"computed":[],"activity":"Ciepło spalania\nZakres:\nZakres (26 500 – 46 300) kJ/kg\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna","reference":"PN-C-04062:2018-05","norm_bases":["PN-C-04062:2018-05"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej opałowy lekki, olej opałowy ciężki, Inne przetwory naftowe: pozostałość próżniowa (gudron) Ciepło spalania\nZakres:\nZakres (26 500 – 46 300) kJ/kg\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna PN-C-04062:2018-05 Paliwa ciekle: olej opalowy lekki, olej opalowy ciezki, Inne przetwory naftowe: pozostalosc prozniowa (gudron) Cieplo spalania\nZakres:\nZakres (26 500 – 46 300) kJ/kg\nWartosc opalowa (z obliczen)\nMetoda kalorymetryczna PN-C-04062:2018-05","categories":["petro"],"row_index":163,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5e9","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, biopaliwa ciekłe: olej napędowy z FAME, Inne przetwory naftowe: pozostałość próżniowa (gudron)","methodology":"Gęstość","parameters":[{"name":"Zakres","range":"(600 – 1100) kg/m3"}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"computed":[],"activity":"Gęstość\nZakres (600 – 1100) kg/m3\nMetoda oscylacyjna","reference":"ASTM D 4052-22","norm_bases":["ASTM D 4052-22"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, biopaliwa ciekłe: olej napędowy z FAME, Inne przetwory naftowe: pozostałość próżniowa (gudron) Gęstość\nZakres (600 – 1100) kg/m3\nMetoda oscylacyjna ASTM D 4052-22 Paliwa ciekle: olej napedowy, olej opalowy lekki, biopaliwa ciekle: olej napedowy z FAME, Inne przetwory naftowe: pozostalosc prozniowa (gudron) Gestosc\nZakres (600 – 1100) kg/m3\nMetoda oscylacyjna ASTM D 4052-22","categories":["petro"],"row_index":164,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5ea","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, olej opałowy ciężki, Inne przetwory naftowe: pozostałość próżniowa (gudron)","methodology":"Zawartość węgla","parameters":[{"name":"Zakres","range":"(78 – 88) %(m/m)"}],"technique":"Metoda spektrometrii w zakresie podczerwieni IR","techniques":["Metoda spektrometrii w zakresie podczerwieni IR"],"computed":[],"activity":"Zawartość węgla\nZakres (78 – 88) %(m/m)\nMetoda spektrometrii w zakresie podczerwieni IR","reference":"ASTM D 5291-21 Metoda D","norm_bases":["ASTM D 5291-21 Metoda D"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, olej opałowy ciężki, Inne przetwory naftowe: pozostałość próżniowa (gudron) Zawartość węgla\nZakres (78 – 88) %(m/m)\nMetoda spektrometrii w zakresie podczerwieni IR ASTM D 5291-21 Metoda D Paliwa ciekle: olej napedowy, olej opalowy lekki, olej opalowy ciezki, Inne przetwory naftowe: pozostalosc prozniowa (gudron) Zawartosc wegla\nZakres (78 – 88) %(m/m)\nMetoda spektrometrii w zakresie podczerwieni IR ASTM D 5291-21 Metoda D","categories":["petro"],"row_index":165,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5eb","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki","methodology":"Korozja na trzpieniu stalowym","parameters":[],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Korozja na trzpieniu stalowym\nMetoda wizualna","reference":"ASTM D 665-24 | PN-ISO 7120:2011","norm_bases":["ASTM D 665-24","PN-ISO 7120:2011"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki Korozja na trzpieniu stalowym\nMetoda wizualna ASTM D 665-24 | PN-ISO 7120:2011 Paliwa ciekle: benzyna bezolowiowa, olej napedowy, olej opalowy lekki Korozja na trzpieniu stalowym\nMetoda wizualna ASTM D 665-24 | PN-ISO 7120:2011","categories":["petro","materials"],"row_index":166,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5ec","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej opałowy ciężki, Inne przetwory naftowe: olej popirolityczny, pozostałość próżniowa (gudron), frakcje i/lub produkty naftowe o temperaturze wrzenia 20°C - 550°C, asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe","methodology":"Zawartość wody","parameters":[{"name":"Zakres","range":"(0 – 25) %(v/v)"}],"technique":"Metoda destylacyjna","techniques":["Metoda destylacyjna"],"computed":[],"activity":"Zawartość wody\nZakres (0 – 25) %(v/v)\nMetoda destylacyjna","reference":"PN-ISO 3733:2008","norm_bases":["PN-ISO 3733:2008"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej opałowy ciężki, Inne przetwory naftowe: olej popirolityczny, pozostałość próżniowa (gudron), frakcje i/lub produkty naftowe o temperaturze wrzenia 20°C - 550°C, asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe Zawartość wody\nZakres (0 – 25) %(v/v)\nMetoda destylacyjna PN-ISO 3733:2008 Paliwa ciekle: olej opalowy ciezki, Inne przetwory naftowe: olej popirolityczny, pozostalosc prozniowa (gudron), frakcje i/lub produkty naftowe o temperaturze wrzenia 20°C - 550°C, asfalty drogowe, asfalty przemyslowe i wyroby asfaltowe Zawartosc wody\nZakres (0 – 25) %(v/v)\nMetoda destylacyjna PN-ISO 3733:2008","categories":["petro","water"],"row_index":167,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5ed","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: olej napędowy z FAME, estry metylowe kwasów tłuszczowych (FAME)","methodology":"Lepkość kinematyczna w temp. 40 oC","parameters":[{"name":"Zakres","range":"(1,000 – 150,0) mm2/s"}],"technique":"Metoda kapilarna","techniques":["Metoda kapilarna"],"computed":[],"activity":"Lepkość kinematyczna w temp. 40 oC\nZakres (1,000 – 150,0) mm2/s\nMetoda kapilarna","reference":"PN-EN ISO 3104:2024-01","norm_bases":["PN-EN ISO 3104:2024-01"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: olej napędowy z FAME, estry metylowe kwasów tłuszczowych (FAME) Lepkość kinematyczna w temp. 40 oC\nZakres (1,000 – 150,0) mm2/s\nMetoda kapilarna PN-EN ISO 3104:2024-01 Paliwa ciekle: biopaliwa ciekle: olej napedowy z FAME, estry metylowe kwasow tluszczowych (FAME) Lepkosc kinematyczna w temp. 40 oC\nZakres (1,000 – 150,0) mm2/s\nMetoda kapilarna PN-EN ISO 3104:2024-01","categories":["petro"],"row_index":168,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5ee","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: olej napędowy z FAME, estry metylowe kwasów tłuszczowych (FAME)","methodology":"Stabilność oksydacyjna","parameters":[{"name":"Zakres","range":"(0,1 – 25,0) h"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Stabilność oksydacyjna\nZakres (0,1 – 25,0) h\nMetoda konduktometryczna","reference":"PN-EN 15751:2014-05","norm_bases":["PN-EN 15751:2014-05"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: olej napędowy z FAME, estry metylowe kwasów tłuszczowych (FAME) Stabilność oksydacyjna\nZakres (0,1 – 25,0) h\nMetoda konduktometryczna PN-EN 15751:2014-05 Paliwa ciekle: biopaliwa ciekle: olej napedowy z FAME, estry metylowe kwasow tluszczowych (FAME) Stabilnosc oksydacyjna\nZakres (0,1 – 25,0) h\nMetoda konduktometryczna PN-EN 15751:2014-05","categories":["petro"],"row_index":169,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5ef","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość popiołu siarczanowego","parameters":[{"name":"Zakres","range":"(0,005 – 0,25) %(m/m)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość popiołu siarczanowego\nZakres (0,005 – 0,25) %(m/m)\nMetoda wagowa","reference":"PN-ISO 3987:2014-05","norm_bases":["PN-ISO 3987:2014-05"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Zawartość popiołu siarczanowego\nZakres (0,005 – 0,25) %(m/m)\nMetoda wagowa PN-ISO 3987:2014-05 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Zawartosc popiolu siarczanowego\nZakres (0,005 – 0,25) %(m/m)\nMetoda wagowa PN-ISO 3987:2014-05","categories":["petro"],"row_index":170,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5f0","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Stabilność oksydacyjna","parameters":[{"name":"Zakres","range":"(0,1 – 14,0) h"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Stabilność oksydacyjna\nZakres (0,1 – 14,0) h\nMetoda konduktometryczna","reference":"PN-EN 14112:2021-05","norm_bases":["PN-EN 14112:2021-05"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Stabilność oksydacyjna\nZakres (0,1 – 14,0) h\nMetoda konduktometryczna PN-EN 14112:2021-05 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Stabilnosc oksydacyjna\nZakres (0,1 – 14,0) h\nMetoda konduktometryczna PN-EN 14112:2021-05","categories":["petro"],"row_index":171,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5f1","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Skłonność do blokowania filtra po wychładzaniu","parameters":[{"name":"Zakres","range":"(50 – 720) s"}],"technique":"Metoda CSFT","techniques":["Metoda CSFT"],"computed":[],"activity":"Skłonność do blokowania filtra po wychładzaniu\nZakres (50 – 720) s\nMetoda CSFT","reference":"ASTM D 7501-22","norm_bases":["ASTM D 7501-22"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Skłonność do blokowania filtra po wychładzaniu\nZakres (50 – 720) s\nMetoda CSFT ASTM D 7501-22 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Sklonnosc do blokowania filtra po wychladzaniu\nZakres (50 – 720) s\nMetoda CSFT ASTM D 7501-22","categories":["petro"],"row_index":172,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5f2","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość metali grupy I","parameters":[{"name":"Na","range":"(1 – 10) mg/kg"},{"name":"K","range":"(1 – 10) mg/kg"},{"name":"Suma (Na i K) mg/kg (z obliczeń)"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość metali grupy I\nZakres:\nNa (1 – 10) mg/kg\nK (1 – 10) mg/kg\nSuma (Na i K) mg/kg (z obliczeń)\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN 14538:2008","norm_bases":["PN-EN 14538:2008"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Zawartość metali grupy I\nZakres:\nNa (1 – 10) mg/kg\nK (1 – 10) mg/kg\nSuma (Na i K) mg/kg (z obliczeń)\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN 14538:2008 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Zawartosc metali grupy I\nZakres:\nNa (1 – 10) mg/kg\nK (1 – 10) mg/kg\nSuma (Na i K) mg/kg (z obliczen)\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN 14538:2008","categories":["materials","petro"],"row_index":173,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5f3","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość metali grupy II","parameters":[{"name":"Ca","range":"(1 – 10) mg/kg"},{"name":"Mg","range":"(1,2 – 10) mg/kg"},{"name":"Suma (Ca i Mg) mg/kg (z obliczeń)"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość metali grupy II\nZakres:\nCa (1 – 10) mg/kg\nMg (1,2 – 10) mg/kg\nSuma (Ca i Mg) mg/kg (z obliczeń)\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN 14538:2008","norm_bases":["PN-EN 14538:2008"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Zawartość metali grupy II\nZakres:\nCa (1 – 10) mg/kg\nMg (1,2 – 10) mg/kg\nSuma (Ca i Mg) mg/kg (z obliczeń)\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN 14538:2008 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Zawartosc metali grupy II\nZakres:\nCa (1 – 10) mg/kg\nMg (1,2 – 10) mg/kg\nSuma (Ca i Mg) mg/kg (z obliczen)\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN 14538:2008","categories":["materials","petro"],"row_index":174,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5f4","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość fosforu","parameters":[{"name":"Zakres","range":"(4 – 20) mg/kg"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość fosforu\nZakres (4 – 20) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN 14107:2004","norm_bases":["PN-EN 14107:2004"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Zawartość fosforu\nZakres (4 – 20) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN 14107:2004 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Zawartosc fosforu\nZakres (4 – 20) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN 14107:2004","categories":["petro"],"row_index":175,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5f5","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy","methodology":"Zawartość manganu","parameters":[{"name":"Zakres","range":"(0,5 – 7,0) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość manganu\nZakres (0,5 – 7,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN 16576:2014-12+Ap1:2017-11","norm_bases":["PN-EN 16576:2014-12+Ap1:2017-11"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy Zawartość manganu\nZakres (0,5 – 7,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w indukcyjnie sprzężonej (ICP-OES) PN-EN 16576:2014-12+Ap1:2017-11 Paliwa ciekle: olej napedowy Zawartosc manganu\nZakres (0,5 – 7,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w indukcyjnie sprzezonej (ICP-OES) PN-EN 16576:2014-12+Ap1:2017-11","categories":["petro"],"row_index":176,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5f6","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy","methodology":"Stabilność oksydacyjna","parameters":[{"name":"Zakres","range":"(5,0 – 50,0) h"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Stabilność oksydacyjna\nZakres (5,0 – 50,0) h\nMetoda konduktometryczna","reference":"PN-EN 15751:2014-05","norm_bases":["PN-EN 15751:2014-05"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy Stabilność oksydacyjna\nZakres (5,0 – 50,0) h\nMetoda konduktometryczna PN-EN 15751:2014-05 Paliwa ciekle: olej napedowy Stabilnosc oksydacyjna\nZakres (5,0 – 50,0) h\nMetoda konduktometryczna PN-EN 15751:2014-05","categories":["petro"],"row_index":177,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5f7","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, Inne przetwory naftowe: olej popirolityczny, pozostałość próżniowa (gudron), frakcje i/lub produkty naftowe o temperaturze wrzenia 50°C - 570°C","methodology":"Zawartość wody","parameters":[{"name":"Zakres","range":"(0,003 – 0,100) %(m/m)"}],"technique":"Metoda miareczkowania potencjometrycznego","techniques":["Metoda miareczkowania potencjometrycznego"],"computed":[],"activity":"Zawartość wody\nZakres (0,003 – 0,100) %(m/m)\nMetoda miareczkowania potencjometrycznego","reference":"PN-ISO 6296:2011","norm_bases":["PN-ISO 6296:2011"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, Inne przetwory naftowe: olej popirolityczny, pozostałość próżniowa (gudron), frakcje i/lub produkty naftowe o temperaturze wrzenia 50°C - 570°C Zawartość wody\nZakres (0,003 – 0,100) %(m/m)\nMetoda miareczkowania potencjometrycznego PN-ISO 6296:2011 Paliwa ciekle: olej napedowy, Inne przetwory naftowe: olej popirolityczny, pozostalosc prozniowa (gudron), frakcje i/lub produkty naftowe o temperaturze wrzenia 50°C - 570°C Zawartosc wody\nZakres (0,003 – 0,100) %(m/m)\nMetoda miareczkowania potencjometrycznego PN-ISO 6296:2011","categories":["petro","water"],"row_index":178,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5f8","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy ciężki, Inne przetwory naftowe: olej popirolityczny, pozostałość próżniowa (gudron), frakcje i/lub produkty naftowe o temperaturze wrzenia 20°C - 550°C","methodology":"Zawartość siarkowodoru","parameters":[{"name":"Zakres","range":"(0,10 – 48,0) mg/kg"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Zawartość siarkowodoru\nZakres (0,10 – 48,0) mg/kg\nMetoda elektrochemiczna","reference":"IP 570/15(2021)","norm_bases":["IP 570/15(2021)"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy ciężki, Inne przetwory naftowe: olej popirolityczny, pozostałość próżniowa (gudron), frakcje i/lub produkty naftowe o temperaturze wrzenia 20°C - 550°C Zawartość siarkowodoru\nZakres (0,10 – 48,0) mg/kg\nMetoda elektrochemiczna IP 570/15(2021) Paliwa ciekle: olej napedowy, olej opalowy ciezki, Inne przetwory naftowe: olej popirolityczny, pozostalosc prozniowa (gudron), frakcje i/lub produkty naftowe o temperaturze wrzenia 20°C - 550°C Zawartosc siarkowodoru\nZakres (0,10 – 48,0) mg/kg\nMetoda elektrochemiczna IP 570/15(2021)","categories":["petro"],"row_index":179,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5f9","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej opałowy ciężki, Inne przetwory naftowe: pozostałości próżniowe","methodology":"Zawartość całkowitego osadu","parameters":[{"name":"Zakres","range":"(0,01 – 0,50) %(m/m)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość całkowitego osadu\nZakres (0,01 – 0,50) %(m/m)\nMetoda wagowa","reference":"PN-ISO 10307-1:2010 | ASTM D 4870-22","norm_bases":["PN-ISO 10307-1:2010","ASTM D 4870-22"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej opałowy ciężki, Inne przetwory naftowe: pozostałości próżniowe Zawartość całkowitego osadu\nZakres (0,01 – 0,50) %(m/m)\nMetoda wagowa PN-ISO 10307-1:2010 | ASTM D 4870-22 Paliwa ciekle: olej opalowy ciezki, Inne przetwory naftowe: pozostalosci prozniowe Zawartosc calkowitego osadu\nZakres (0,01 – 0,50) %(m/m)\nMetoda wagowa PN-ISO 10307-1:2010 | ASTM D 4870-22","categories":["petro","water"],"row_index":180,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5fa","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna, olej napędowy, olej opałowy lekki, olej opałowy ciężki, Inne przetwory naftowe: pozostałość próżniowa (gudron), Materiały smarne: oleje bazowe smarowe","methodology":"Odczyn wyciągu wodnego","parameters":[{"name":"Zakres","range":"zasadowy – kwaśny (wartość pH 2,7 –12,4)"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Odczyn wyciągu wodnego\nZakres zasadowy – kwaśny (wartość pH 2,7 –12,4)\nMetoda elektrochemiczna","reference":"PN-C-96060:2019-03 Procedura A","norm_bases":["PN-C-96060:2019-03 Procedura A"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna, olej napędowy, olej opałowy lekki, olej opałowy ciężki, Inne przetwory naftowe: pozostałość próżniowa (gudron), Materiały smarne: oleje bazowe smarowe Odczyn wyciągu wodnego\nZakres zasadowy – kwaśny (wartość pH 2,7 –12,4)\nMetoda elektrochemiczna PN-C-96060:2019-03 Procedura A Paliwa ciekle: benzyna, olej napedowy, olej opalowy lekki, olej opalowy ciezki, Inne przetwory naftowe: pozostalosc prozniowa (gudron), Materialy smarne: oleje bazowe smarowe Odczyn wyciagu wodnego\nZakres zasadowy – kwasny (wartosc pH 2,7 –12,4)\nMetoda elektrochemiczna PN-C-96060:2019-03 Procedura A","categories":["petro","materials"],"row_index":181,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5fb","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiały smarne: oleje bazowe, oleje silnikowe, przemysłowe oleje smarowe","methodology":"Wskaźnik lepkości na podstawie lepkości kinematycznej w 40 °C i w 100 °C","parameters":[{"name":"Zakres","range":"(85 – 100) dla olejów smarowych"},{"name":"bazowych (60 – 150) dla olejów smarowych uszlachetnionych (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik lepkości na podstawie lepkości kinematycznej w 40 °C i w 100 °C\nZakres:\nZakres (85 – 100) dla olejów smarowych\nbazowych (60 – 150) dla olejów smarowych uszlachetnionych (z obliczeń)","reference":"PN-ISO 2909:2009+Ap1:2010","norm_bases":["PN-ISO 2909:2009+Ap1:2010"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały smarne: oleje bazowe, oleje silnikowe, przemysłowe oleje smarowe Wskaźnik lepkości na podstawie lepkości kinematycznej w 40 °C i w 100 °C\nZakres:\nZakres (85 – 100) dla olejów smarowych\nbazowych (60 – 150) dla olejów smarowych uszlachetnionych (z obliczeń) PN-ISO 2909:2009+Ap1:2010 Materialy smarne: oleje bazowe, oleje silnikowe, przemyslowe oleje smarowe Wskaznik lepkosci na podstawie lepkosci kinematycznej w 40 °C i w 100 °C\nZakres:\nZakres (85 – 100) dla olejow smarowych\nbazowych (60 – 150) dla olejow smarowych uszlachetnionych (z obliczen) PN-ISO 2909:2009+Ap1:2010","categories":["materials","petro"],"row_index":182,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5fc","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiały smarne: oleje bazowe, oleje silnikowe, przemysłowe oleje smarowe","methodology":"Barwa","parameters":[{"name":"Zakres","range":"0,5 – 8,0"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Barwa\nZakres 0,5 – 8,0\nMetoda wizualna","reference":"ASTM D 1500-24","norm_bases":["ASTM D 1500-24"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały smarne: oleje bazowe, oleje silnikowe, przemysłowe oleje smarowe Barwa\nZakres 0,5 – 8,0\nMetoda wizualna ASTM D 1500-24 Materialy smarne: oleje bazowe, oleje silnikowe, przemyslowe oleje smarowe Barwa\nZakres 0,5 – 8,0\nMetoda wizualna ASTM D 1500-24","categories":["materials","petro"],"row_index":183,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5fd","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiały smarne: oleje bazowe, oleje silnikowe, przemysłowe oleje smarowe","methodology":"Temperatura zapłonu","parameters":[{"name":"Zakres","range":"(110 – 280) °C"}],"technique":"Metoda otwartego tygla Cleveland’a","techniques":["Metoda otwartego tygla Cleveland’a"],"computed":[],"activity":"Temperatura zapłonu\nZakres (110 – 280) °C\nMetoda otwartego tygla Cleveland’a","reference":"PN-EN ISO 2592:2017-10","norm_bases":["PN-EN ISO 2592:2017-10"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały smarne: oleje bazowe, oleje silnikowe, przemysłowe oleje smarowe Temperatura zapłonu\nZakres (110 – 280) °C\nMetoda otwartego tygla Cleveland’a PN-EN ISO 2592:2017-10 Materialy smarne: oleje bazowe, oleje silnikowe, przemyslowe oleje smarowe Temperatura zaplonu\nZakres (110 – 280) °C\nMetoda otwartego tygla Cleveland’a PN-EN ISO 2592:2017-10","categories":["materials","petro"],"row_index":184,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5fe","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiały smarne: oleje bazowe, oleje silnikowe, przemysłowe oleje smarowe","methodology":"Lepkość kinematyczna w 40°C i 100°C","parameters":[{"name":"Zakres","range":"(2,600 – 200,0) mm2/s"}],"technique":"Metoda kapilarna","techniques":["Metoda kapilarna"],"computed":[],"activity":"Lepkość kinematyczna w 40°C i 100°C\nZakres (2,600 – 200,0) mm2/s\nMetoda kapilarna","reference":"PN-EN ISO 3104:2024-01","norm_bases":["PN-EN ISO 3104:2024-01"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały smarne: oleje bazowe, oleje silnikowe, przemysłowe oleje smarowe Lepkość kinematyczna w 40°C i 100°C\nZakres (2,600 – 200,0) mm2/s\nMetoda kapilarna PN-EN ISO 3104:2024-01 Materialy smarne: oleje bazowe, oleje silnikowe, przemyslowe oleje smarowe Lepkosc kinematyczna w 40°C i 100°C\nZakres (2,600 – 200,0) mm2/s\nMetoda kapilarna PN-EN ISO 3104:2024-01","categories":["materials","petro"],"row_index":185,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb5ff","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiały smarne: oleje bazowe, oleje silnikowe, przemysłowe oleje smarowe","methodology":"Temperatura płynięcia","parameters":[{"name":"[(+6)","range":"(-30)] °C"}],"technique":"Metoda optyczna i wizualna","techniques":["Metoda optyczna i wizualna"],"computed":[],"activity":"Temperatura płynięcia\n[(+6) (-30)] °C\nMetoda optyczna i wizualna","reference":"PN-EN ISO 3016:2019-06","norm_bases":["PN-EN ISO 3016:2019-06"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały smarne: oleje bazowe, oleje silnikowe, przemysłowe oleje smarowe Temperatura płynięcia\n[(+6) (-30)] °C\nMetoda optyczna i wizualna PN-EN ISO 3016:2019-06 Materialy smarne: oleje bazowe, oleje silnikowe, przemyslowe oleje smarowe Temperatura plyniecia\n[(+6) (-30)] °C\nMetoda optyczna i wizualna PN-EN ISO 3016:2019-06","categories":["materials","petro"],"row_index":186,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb600","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiały smarne: oleje bazowe, oleje silnikowe, przemysłowe oleje smarowe","methodology":"Liczba kwasowa","parameters":[{"name":"Zakres","range":"(0,1 – 5,0) mg KOH/g"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Liczba kwasowa\nZakres (0,1 – 5,0) mg KOH/g\nMetoda miareczkowa","reference":"PN-ISO 6618:2011","norm_bases":["PN-ISO 6618:2011"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały smarne: oleje bazowe, oleje silnikowe, przemysłowe oleje smarowe Liczba kwasowa\nZakres (0,1 – 5,0) mg KOH/g\nMetoda miareczkowa PN-ISO 6618:2011 Materialy smarne: oleje bazowe, oleje silnikowe, przemyslowe oleje smarowe Liczba kwasowa\nZakres (0,1 – 5,0) mg KOH/g\nMetoda miareczkowa PN-ISO 6618:2011","categories":["materials","petro"],"row_index":187,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb601","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiały smarne: oleje bazowe, oleje silnikowe, przemysłowe oleje smarowe","methodology":"Pozostałość po spopieleniu","parameters":[{"name":"Zakres","range":"(0,001 – 0,005) %(m/m)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Pozostałość po spopieleniu\nZakres (0,001 – 0,005) %(m/m)\nMetoda wagowa","reference":"PN-EN ISO 6245:2008","norm_bases":["PN-EN ISO 6245:2008"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały smarne: oleje bazowe, oleje silnikowe, przemysłowe oleje smarowe Pozostałość po spopieleniu\nZakres (0,001 – 0,005) %(m/m)\nMetoda wagowa PN-EN ISO 6245:2008 Materialy smarne: oleje bazowe, oleje silnikowe, przemyslowe oleje smarowe Pozostalosc po spopieleniu\nZakres (0,001 – 0,005) %(m/m)\nMetoda wagowa PN-EN ISO 6245:2008","categories":["materials","petro"],"row_index":188,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb602","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiały smarne: przemysłowe oleje smarowe, Paliwa ciekłe: olej opałowy ciężki","methodology":"Zawartość wody","parameters":[{"name":"Zakres","range":"(0,05 – 5,00) %(v/m)"}],"technique":"Metoda destylacyjna","techniques":["Metoda destylacyjna"],"computed":[],"activity":"Zawartość wody\nZakres (0,05 – 5,00) %(v/m)\nMetoda destylacyjna","reference":"ASTM D 95-23ɛ1","norm_bases":["ASTM D 95-23ɛ1"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały smarne: przemysłowe oleje smarowe, Paliwa ciekłe: olej opałowy ciężki Zawartość wody\nZakres (0,05 – 5,00) %(v/m)\nMetoda destylacyjna ASTM D 95-23ɛ1 Materialy smarne: przemyslowe oleje smarowe, Paliwa ciekle: olej opalowy ciezki Zawartosc wody\nZakres (0,05 – 5,00) %(v/m)\nMetoda destylacyjna ASTM D 95-23ɛ1","categories":["petro","materials","water"],"row_index":189,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb603","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Inne przetwory naftowe: gacz parafinowy","methodology":"Zawartość oleju","parameters":[{"name":"Zakres","range":"(0,20 – 15,00) %(m/m)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość oleju\nZakres (0,20 – 15,00) %(m/m)\nMetoda wagowa","reference":"ASTM D 721-25","norm_bases":["ASTM D 721-25"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Inne przetwory naftowe: gacz parafinowy Zawartość oleju\nZakres (0,20 – 15,00) %(m/m)\nMetoda wagowa ASTM D 721-25 Inne przetwory naftowe: gacz parafinowy Zawartosc oleju\nZakres (0,20 – 15,00) %(m/m)\nMetoda wagowa ASTM D 721-25","categories":["petro"],"row_index":190,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb604","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Inne przetwory naftowe: gacz parafinowy","methodology":"Temperatura krzepnięcia","parameters":[{"name":"Zakres","range":"(45 – 65) °C"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Temperatura krzepnięcia\nZakres (45 – 65) °C\nMetoda wizualna","reference":"PN-ISO 2207:2011","norm_bases":["PN-ISO 2207:2011"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Inne przetwory naftowe: gacz parafinowy Temperatura krzepnięcia\nZakres (45 – 65) °C\nMetoda wizualna PN-ISO 2207:2011 Inne przetwory naftowe: gacz parafinowy Temperatura krzepniecia\nZakres (45 – 65) °C\nMetoda wizualna PN-ISO 2207:2011","categories":["other"],"row_index":191,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb605","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie metali","parameters":[{"name":"Cr, Cd, Pb, Cu, Ni, Zn, Fe, V"},{"name":"Zakres","range":"(0,010 – 100) mg/l"},{"name":"Co, Ag, Ba, B, Al","range":"(0,010 – 50,0) mg/l"},{"name":"Na, K, Ca, Mg","range":"(1,00 – 1000) mg/l"},{"name":"Stężenie metali As, Sb","range":"(0,010 – 20,0) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES); Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES)"],"computed":[],"activity":"Stężenie metali\nZakres:\nCr, Cd, Pb, Cu, Ni, Zn, Fe, V\nZakres (0,010 – 100) mg/l\nCo, Ag, Ba, B, Al (0,010 – 50,0) mg/l\nNa, K, Ca, Mg (1,00 – 1000) mg/l\nStężenie metali As, Sb (0,010 – 20,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES); Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie metali\nZakres:\nCr, Cd, Pb, Cu, Ni, Zn, Fe, V\nZakres (0,010 – 100) mg/l\nCo, Ag, Ba, B, Al (0,010 – 50,0) mg/l\nNa, K, Ca, Mg (1,00 – 1000) mg/l\nStężenie metali As, Sb (0,010 – 20,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES); Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES) PN-EN ISO 11885:2009 Scieki Stezenie metali\nZakres:\nCr, Cd, Pb, Cu, Ni, Zn, Fe, V\nZakres (0,010 – 100) mg/l\nCo, Ag, Ba, B, Al (0,010 – 50,0) mg/l\nNa, K, Ca, Mg (1,00 – 1000) mg/l\nStezenie metali As, Sb (0,010 – 20,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES); Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej z generowaniem wodorkow (HG-ICP-OES) PN-EN ISO 11885:2009","categories":["materials","water"],"row_index":192,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb606","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki oczyszczone","methodology":"Stężenie metali","parameters":[{"name":"Cr, Cd, Cu, Ni, Mn, V","range":"(0,010 – 2,00) mg/l"},{"name":"Mg, K, Na, Ca","range":"(1,00 – 1000) mg/l"},{"name":"Zn, Pb, Fe","range":"(0,010 – 100) mg/l"},{"name":"Ba, Al., Ag","range":"(0,010 – 50,0) mg/l"},{"name":"Stężenie metali As","range":"(0,010 – 2,00) mg/l"},{"name":"Se, Sb","range":"(0.010 – 20,0) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES); Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnej sprzężonej z generowaniem wodorków (HG-ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnej sprzężonej z generowaniem wodorków (HG-ICP-OES)"],"computed":[],"activity":"Stężenie metali\nZakres:\nCr, Cd, Cu, Ni, Mn, V (0,010 – 2,00) mg/l\nMg, K, Na, Ca (1,00 – 1000) mg/l\nZn, Pb, Fe (0,010 – 100) mg/l\nBa, Al., Ag (0,010 – 50,0) mg/l\nStężenie metali As (0,010 – 2,00) mg/l\nSe, Sb (0.010 – 20,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES); Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnej sprzężonej z generowaniem wodorków (HG-ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki oczyszczone Stężenie metali\nZakres:\nCr, Cd, Cu, Ni, Mn, V (0,010 – 2,00) mg/l\nMg, K, Na, Ca (1,00 – 1000) mg/l\nZn, Pb, Fe (0,010 – 100) mg/l\nBa, Al., Ag (0,010 – 50,0) mg/l\nStężenie metali As (0,010 – 2,00) mg/l\nSe, Sb (0.010 – 20,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES); Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnej sprzężonej z generowaniem wodorków (HG-ICP-OES) PN-EN ISO 11885:2009 Woda, scieki oczyszczone Stezenie metali\nZakres:\nCr, Cd, Cu, Ni, Mn, V (0,010 – 2,00) mg/l\nMg, K, Na, Ca (1,00 – 1000) mg/l\nZn, Pb, Fe (0,010 – 100) mg/l\nBa, Al., Ag (0,010 – 50,0) mg/l\nStezenie metali As (0,010 – 2,00) mg/l\nSe, Sb (0.010 – 20,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES); Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnej sprzezonej z generowaniem wodorkow (HG-ICP-OES) PN-EN ISO 11885:2009","categories":["water","materials"],"row_index":193,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb607","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie pierwiastków As, Cr, Cd, Pb","parameters":[{"name":"Zakres","range":"(0,00010 – 0,050) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej z detekcją spektrometrią mas (ICP-MS)","techniques":["Metoda emisyjnej spektrometrii atomowej z detekcją spektrometrią mas (ICP-MS)"],"computed":[],"activity":"Stężenie pierwiastków As, Cr, Cd, Pb\nZakres (0,00010 – 0,050) mg/l\nMetoda emisyjnej spektrometrii atomowej z detekcją spektrometrią mas (ICP-MS)","reference":"PN-EN ISO 17294-2:2024-04","norm_bases":["PN-EN ISO 17294-2:2024-04"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie pierwiastków As, Cr, Cd, Pb\nZakres (0,00010 – 0,050) mg/l\nMetoda emisyjnej spektrometrii atomowej z detekcją spektrometrią mas (ICP-MS) PN-EN ISO 17294-2:2024-04 Woda, scieki Stezenie pierwiastkow As, Cr, Cd, Pb\nZakres (0,00010 – 0,050) mg/l\nMetoda emisyjnej spektrometrii atomowej z detekcja spektrometria mas (ICP-MS) PN-EN ISO 17294-2:2024-04","categories":["water"],"row_index":194,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb608","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiały budowlane: gips","methodology":"Zawartość Na2O, K2O","parameters":[{"name":"Na2O","range":"(0,010 – 0,500) %(m/m)"},{"name":"K2O","range":"(0,010 – 0,500) %(m/m)"},{"name":"Zawartość rozpuszczonego MgO MgO","range":"(0,001 – 0,100) %(m/m)"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość Na2O, K2O\nZakres:\nNa2O (0,010 – 0,500) %(m/m)\nK2O (0,010 – 0,500) %(m/m)\nZawartość rozpuszczonego MgO MgO (0,001 – 0,100) %(m/m)\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"VGB-M 701-e/2008 p. 8.7","norm_bases":["VGB-M 701-e/2008 p. 8.7"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały budowlane: gips Zawartość Na2O, K2O\nZakres:\nNa2O (0,010 – 0,500) %(m/m)\nK2O (0,010 – 0,500) %(m/m)\nZawartość rozpuszczonego MgO MgO (0,001 – 0,100) %(m/m)\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) VGB-M 701-e/2008 p. 8.7 Materialy budowlane: gips Zawartosc Na2O, K2O\nZakres:\nNa2O (0,010 – 0,500) %(m/m)\nK2O (0,010 – 0,500) %(m/m)\nZawartosc rozpuszczonego MgO MgO (0,001 – 0,100) %(m/m)\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) VGB-M 701-e/2008 p. 8.7","categories":["materials","construction"],"row_index":195,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb609","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Pobieranie próbek do oceny narażenia zawodowego na:","parameters":[{"name":"czynniki pyłowe"},{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna"},{"name":"metale i ich związki, w tym"},{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna"},{"name":"substancje organiczne, w tym"},{"name":"frakcja wdychalna"},{"name":"substancje nieorganiczne, w tym"},{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna"},{"name":"frakcja torakalna"}],"technique":"Metoda dozymetrii indywidualnej","techniques":["Metoda dozymetrii indywidualnej"],"computed":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe\nfrakcja wdychalna\nfrakcja respirabilna\nmetale i ich związki, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nsubstancje organiczne, w tym\nfrakcja wdychalna\nsubstancje nieorganiczne, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nfrakcja torakalna\nMetoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002+Az1:2004"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe\nfrakcja wdychalna\nfrakcja respirabilna\nmetale i ich związki, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nsubstancje organiczne, w tym\nfrakcja wdychalna\nsubstancje nieorganiczne, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nfrakcja torakalna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy − powietrze Pobieranie probek do oceny narazenia zawodowego na:\nZakres:\nczynniki pylowe\nfrakcja wdychalna\nfrakcja respirabilna\nmetale i ich zwiazki, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nsubstancje organiczne, w tym\nfrakcja wdychalna\nsubstancje nieorganiczne, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nfrakcja torakalna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002+Az1:2004","categories":["environment"],"row_index":196,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb60a","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Pobieranie próbek do oceny narażenia zawodowego na:","parameters":[{"name":"substancje organiczne,"},{"name":"substancje nieorganiczne, w tym"},{"name":"frakcja wdychalna"}],"technique":"Metoda stacjonarna","techniques":["Metoda stacjonarna"],"computed":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nsubstancje organiczne,\nsubstancje nieorganiczne, w tym\nfrakcja wdychalna\nMetoda stacjonarna","reference":"PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002+Az1:2004"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nsubstancje organiczne,\nsubstancje nieorganiczne, w tym\nfrakcja wdychalna\nMetoda stacjonarna PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy − powietrze Pobieranie probek do oceny narazenia zawodowego na:\nZakres:\nsubstancje organiczne,\nsubstancje nieorganiczne, w tym\nfrakcja wdychalna\nMetoda stacjonarna PN-Z-04008-7:2002+Az1:2004","categories":["environment"],"row_index":197,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb60b","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Wskaźnik narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002+Az1:2004"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Wskaźnik narażenia (z obliczeń) PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy − powietrze Wskaznik narazenia (z obliczen) PN-Z-04008-7:2002+Az1:2004","categories":["environment"],"row_index":198,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb60c","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość glikolu etylenowego","parameters":[{"name":"Zakres","range":"(0,83 – 333,3)mg/m3"},{"name":"Zakres","range":"(0,025 – 1,00) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość glikolu etylenowego\nZakres:\nZakres (0,83 – 333,3)mg/m3\nZakres (0,025 – 1,00) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-88/Z-04203.02","norm_bases":["PN-88/Z-04203.02"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość glikolu etylenowego\nZakres:\nZakres (0,83 – 333,3)mg/m3\nZakres (0,025 – 1,00) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-88/Z-04203.02 Srodowisko pracy − powietrze Stezenie/zawartosc glikolu etylenowego\nZakres:\nZakres (0,83 – 333,3)mg/m3\nZakres (0,025 – 1,00) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-88/Z-04203.02","categories":["environment"],"row_index":199,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb60d","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość buta-1,3-dienu","parameters":[{"name":"Zakres","range":"(0,13 – 6,67) mg/m3"},{"name":"Zakres","range":"(0,004 – 0,150) mg w próbce"},{"name":"Zakres","range":"(0,06 – 2,97) ppm"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość buta-1,3-dienu\nZakres:\nZakres (0,13 – 6,67) mg/m3\nZakres (0,004 – 0,150) mg w próbce\nZakres (0,06 – 2,97) ppm\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-84/Z-04014.02","norm_bases":["PN-84/Z-04014.02"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość buta-1,3-dienu\nZakres:\nZakres (0,13 – 6,67) mg/m3\nZakres (0,004 – 0,150) mg w próbce\nZakres (0,06 – 2,97) ppm\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-84/Z-04014.02 Srodowisko pracy − powietrze Stezenie/zawartosc buta-1,3-dienu\nZakres:\nZakres (0,13 – 6,67) mg/m3\nZakres (0,004 – 0,150) mg w probce\nZakres (0,06 – 2,97) ppm\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-84/Z-04014.02","categories":["environment"],"row_index":200,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb60e","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość buta-1,3-dienu","parameters":[{"name":"Zakres","range":"(0,22 – 4,44) mg/m3"},{"name":"Zakres","range":"(0,00098 – 0,02) mg w próbce"},{"name":"Zakres","range":"(0,10 – 1,98) ppm"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość buta-1,3-dienu\nZakres:\nZakres (0,22 – 4,44) mg/m3\nZakres (0,00098 – 0,02) mg w próbce\nZakres (0,10 – 1,98) ppm\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04438:2021-07","norm_bases":["PN-Z-04438:2021-07"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość buta-1,3-dienu\nZakres:\nZakres (0,22 – 4,44) mg/m3\nZakres (0,00098 – 0,02) mg w próbce\nZakres (0,10 – 1,98) ppm\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04438:2021-07 Srodowisko pracy − powietrze Stezenie/zawartosc buta-1,3-dienu\nZakres:\nZakres (0,22 – 4,44) mg/m3\nZakres (0,00098 – 0,02) mg w probce\nZakres (0,10 – 1,98) ppm\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04438:2021-07","categories":["environment"],"row_index":201,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb60f","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość NN-dimetyloformamidu","parameters":[{"name":"Zakres","range":"(1,00 – 333,3) mg/m3"},{"name":"Zakres","range":"(0,03 – 1,00) mg w próbce"},{"name":"Zakres","range":"(0,33 – 109,9) ppm"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość NN-dimetyloformamidu\nZakres:\nZakres (1,00 – 333,3) mg/m3\nZakres (0,03 – 1,00) mg w próbce\nZakres (0,33 – 109,9) ppm\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-89/Z-04209.02","norm_bases":["PN-89/Z-04209.02"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość NN-dimetyloformamidu\nZakres:\nZakres (1,00 – 333,3) mg/m3\nZakres (0,03 – 1,00) mg w próbce\nZakres (0,33 – 109,9) ppm\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-89/Z-04209.02 Srodowisko pracy − powietrze Stezenie/zawartosc NN-dimetyloformamidu\nZakres:\nZakres (1,00 – 333,3) mg/m3\nZakres (0,03 – 1,00) mg w probce\nZakres (0,33 – 109,9) ppm\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-89/Z-04209.02","categories":["environment"],"row_index":202,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb610","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość epoksyetanu","parameters":[{"name":"Zakres","range":"(0,07 – 2,13) mg/m3"},{"name":"Zakres","range":"(0,002 – 0,048) mg w próbce"},{"name":"Zakres","range":"(0,04 – 1,17) ppm"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość epoksyetanu\nZakres:\nZakres (0,07 – 2,13) mg/m3\nZakres (0,002 – 0,048) mg w próbce\nZakres (0,04 – 1,17) ppm\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04300:2002","norm_bases":["PN-Z-04300:2002"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość epoksyetanu\nZakres:\nZakres (0,07 – 2,13) mg/m3\nZakres (0,002 – 0,048) mg w próbce\nZakres (0,04 – 1,17) ppm\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04300:2002 Srodowisko pracy − powietrze Stezenie/zawartosc epoksyetanu\nZakres:\nZakres (0,07 – 2,13) mg/m3\nZakres (0,002 – 0,048) mg w probce\nZakres (0,04 – 1,17) ppm\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04300:2002","categories":["environment"],"row_index":203,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb611","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość benzyny ekstrakcyjnej","parameters":[{"name":"Zakres","range":"(2,08 – 1041,7) mg/m3"},{"name":"Zakres","range":"(0,15 – 7,5) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość benzyny ekstrakcyjnej\nZakres:\nZakres (2,08 – 1041,7) mg/m3\nZakres (0,15 – 7,5) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-81/Z-04134.02","norm_bases":["PN-81/Z-04134.02"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość benzyny ekstrakcyjnej\nZakres:\nZakres (2,08 – 1041,7) mg/m3\nZakres (0,15 – 7,5) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-81/Z-04134.02 Srodowisko pracy − powietrze Stezenie/zawartosc benzyny ekstrakcyjnej\nZakres:\nZakres (2,08 – 1041,7) mg/m3\nZakres (0,15 – 7,5) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-81/Z-04134.02","categories":["environment"],"row_index":204,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb612","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość fenolu","parameters":[{"name":"Zakres","range":"(0,50 – 35,00) mg/m3"},{"name":"Zakres","range":"(0,002 – 0,070) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość fenolu\nZakres:\nZakres (0,50 – 35,00) mg/m3\nZakres (0,002 – 0,070) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-Z-04044:1970","norm_bases":["PN-Z-04044:1970"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość fenolu\nZakres:\nZakres (0,50 – 35,00) mg/m3\nZakres (0,002 – 0,070) mg w próbce\nMetoda spektrofotometryczna PN-Z-04044:1970 Srodowisko pracy − powietrze Stezenie/zawartosc fenolu\nZakres:\nZakres (0,50 – 35,00) mg/m3\nZakres (0,002 – 0,070) mg w probce\nMetoda spektrofotometryczna PN-Z-04044:1970","categories":["environment"],"row_index":205,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb613","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie tlenku węgla","parameters":[{"name":"Zakres","range":"(2,3 – 232,4) mg/m3"},{"name":"Zakres","range":"(2,0 – 200,0) ppm"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Stężenie tlenku węgla\nZakres:\nZakres (2,3 – 232,4) mg/m3\nZakres (2,0 – 200,0) ppm\nMetoda elektrochemiczna","reference":"Metoda nr 213 wydanie 1 z dnia 08.09.2025","norm_bases":["Metoda nr 213 wydanie 1 z dnia 08.09.2025"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie tlenku węgla\nZakres:\nZakres (2,3 – 232,4) mg/m3\nZakres (2,0 – 200,0) ppm\nMetoda elektrochemiczna Metoda nr 213 wydanie 1 z dnia 08.09.2025 Srodowisko pracy − powietrze Stezenie tlenku wegla\nZakres:\nZakres (2,3 – 232,4) mg/m3\nZakres (2,0 – 200,0) ppm\nMetoda elektrochemiczna Metoda nr 213 wydanie 1 z dnia 08.09.2025","categories":["environment"],"row_index":206,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb614","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Wskaźnik narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"Metoda nr 213 wydanie 1 z dnia 08.09.2025","norm_bases":["Metoda nr 213 wydanie 1 z dnia 08.09.2025"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Wskaźnik narażenia (z obliczeń) Metoda nr 213 wydanie 1 z dnia 08.09.2025 Srodowisko pracy − powietrze Wskaznik narazenia (z obliczen) Metoda nr 213 wydanie 1 z dnia 08.09.2025","categories":["environment"],"row_index":207,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb615","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość metanolu","parameters":[{"name":"Zakres","range":"(0,05 – 1,0) mg w próbce"},{"name":"Zakres","range":"(10,0 – 666,7) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość metanolu\nZakres:\nZakres (0,05 – 1,0) mg w próbce\nZakres (10,0 – 666,7) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2014, nr 3(81) s 89 – 101","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2014, nr 3(81) s 89 – 101"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość metanolu\nZakres:\nZakres (0,05 – 1,0) mg w próbce\nZakres (10,0 – 666,7) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Podstawy i Metody Oceny Środowiska Pracy 2014, nr 3(81) s 89 – 101 Srodowisko pracy − powietrze Stezenie/zawartosc metanolu\nZakres:\nZakres (0,05 – 1,0) mg w probce\nZakres (10,0 – 666,7) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Podstawy i Metody Oceny Srodowiska Pracy 2014, nr 3(81) s 89 – 101","categories":["environment"],"row_index":208,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb616","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość propan-2-ol","parameters":[{"name":"Zakres","range":"(11,11 – 2400) mg/m3"},{"name":"Zakres","range":"(0,10 – 16,25) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość propan-2-ol\nZakres:\nZakres (11,11 – 2400) mg/m3\nZakres (0,10 – 16,25) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2020, nr 1(103) s 159 – 169","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2020, nr 1(103) s 159 – 169"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość propan-2-ol\nZakres:\nZakres (11,11 – 2400) mg/m3\nZakres (0,10 – 16,25) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Podstawy i Metody Oceny Środowiska Pracy 2020, nr 1(103) s 159 – 169 Srodowisko pracy − powietrze Stezenie/zawartosc propan-2-ol\nZakres:\nZakres (11,11 – 2400) mg/m3\nZakres (0,10 – 16,25) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Podstawy i Metody Oceny Srodowiska Pracy 2020, nr 1(103) s 159 – 169","categories":["environment"],"row_index":209,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb617","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość olejów mineralnych wysokorafinowanych, z wyłączeniem cieczy obróbkowych","parameters":[{"name":"Zakres","range":"(0,14 – 10,00) mg/m3"},{"name":"Zakres","range":"(0,100 – 7,200) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość olejów mineralnych wysokorafinowanych, z wyłączeniem cieczy obróbkowych\nZakres:\nZakres (0,14 – 10,00) mg/m3\nZakres (0,100 – 7,200) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-Z-04108-06:2006+Az1:2009","norm_bases":["PN-Z-04108-06:2006+Az1:2009"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość olejów mineralnych wysokorafinowanych, z wyłączeniem cieczy obróbkowych\nZakres:\nZakres (0,14 – 10,00) mg/m3\nZakres (0,100 – 7,200) mg w próbce\nMetoda spektrofotometryczna PN-Z-04108-06:2006+Az1:2009 Srodowisko pracy − powietrze Stezenie/zawartosc olejow mineralnych wysokorafinowanych, z wylaczeniem cieczy obrobkowych\nZakres:\nZakres (0,14 – 10,00) mg/m3\nZakres (0,100 – 7,200) mg w probce\nMetoda spektrofotometryczna PN-Z-04108-06:2006+Az1:2009","categories":["environment","petro"],"row_index":210,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb618","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze *)","methodology":"Stężenie substancji organicznych*)","parameters":[{"name":"butan","range":"(380 – 3800) mg/m3"},{"name":"propan","range":"(288 – 2880) mg/m3"},{"name":"izobutan","range":"(380 – 3800) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie substancji organicznych*)\nZakres:\nbutan (380 – 3800) mg/m3\npropan (288 – 2880) mg/m3\nizobutan (380 – 3800) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Metoda nr 045 wydanie 2 z dnia 14.02.2017","norm_bases":["Metoda nr 045 wydanie 2 z dnia 14.02.2017"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze *) Stężenie substancji organicznych*)\nZakres:\nbutan (380 – 3800) mg/m3\npropan (288 – 2880) mg/m3\nizobutan (380 – 3800) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Metoda nr 045 wydanie 2 z dnia 14.02.2017 Srodowisko pracy − powietrze *) Stezenie substancji organicznych*)\nZakres:\nbutan (380 – 3800) mg/m3\npropan (288 – 2880) mg/m3\nizobutan (380 – 3800) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Metoda nr 045 wydanie 2 z dnia 14.02.2017","categories":["environment"],"row_index":211,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb619","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość substancji organicznych","parameters":[{"name":"Aceton (0,1 – 10) mg w próbce"},{"name":"Zakres","range":"(3,33 – 3333,3) mg/m3"},{"name":"Butan-2-on (0,036 – 9,0) mg w próbce","range":"(3,00 – 1800,0) mg/m3"},{"name":"Butan","range":"(0,78 – 3888,9) mg/m3"},{"name":"(0,056 – 7,000) mg w próbce Etylobenzen (0,016 – 4,0) mg w próbce","range":"(1,33 – 800) mg/m3"},{"name":"Benzen (0,0015 – 0,15) mg w próbce","range":"(0,05 – 5,0) mg/m3"},{"name":"(0,02 – 1,54) ppm"},{"name":"Heksan (0,008 – 2,0) mg w próbce","range":"(0,67 – 200,0) mg/m3"},{"name":"Cykloheksan (0,028 – 7,0) mg w próbce","range":"(2,33 – 2333,3) mg/m3"},{"name":"Metylocykloheksan (0,040 – 10,0) mg w próbce","range":"(3,33 – 6666,7) mg/m3"},{"name":"Heptan (0,040 – 10,0) mg w próbce","range":"(3,33 – 4000,0) mg/m3"},{"name":"Ksylen - mieszanina izomerów","range":"(1,2-; 1,3-; 1,4-)"},{"name":"(0,008 – 2,0) mg w próbce","range":"(0,67 – 666,7) mg/m3"},{"name":"Kumen (0,008 – 2,0) mg w próbce","range":"(0,67 – 666,7) mg/m3"},{"name":"Oktan (0,040 – 10,0) mg w próbce","range":"(3,33 – 4000,0) mg/m3"},{"name":"Toluen (0,080 – 2,0) mg w próbce","range":"(0,67 – 66,7) mg/m3"},{"name":"Etanol (0,1 – 10) mg w próbce","range":"(3,33 – 3333,3) mg/m3"},{"name":"Izopentan (0,04 – 10) mg w próbce","range":"(3,33 – 6666,7) mg/m3"},{"name":"Pentan (0,04 – 10) mg w próbce","range":"(3,33 – 6666,7) mg/m3"},{"name":"Eter tert-butylometylowy (0,008 – 4) mg w próbce","range":"(1,33 – 800,0) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość substancji organicznych\nZakres:\nAceton (0,1 – 10) mg w próbce\nZakres (3,33 – 3333,3) mg/m3\nButan-2-on (0,036 – 9,0) mg w próbce (3,00 – 1800,0) mg/m3\nButan (0,78 – 3888,9) mg/m3\n(0,056 – 7,000) mg w próbce Etylobenzen (0,016 – 4,0) mg w próbce (1,33 – 800) mg/m3\nBenzen (0,0015 – 0,15) mg w próbce (0,05 – 5,0) mg/m3\n(0,02 – 1,54) ppm\nHeksan (0,008 – 2,0) mg w próbce (0,67 – 200,0) mg/m3\nCykloheksan (0,028 – 7,0) mg w próbce (2,33 – 2333,3) mg/m3\nMetylocykloheksan (0,040 – 10,0) mg w próbce (3,33 – 6666,7) mg/m3\nHeptan (0,040 – 10,0) mg w próbce (3,33 – 4000,0) mg/m3\nKsylen - mieszanina izomerów (1,2-; 1,3-; 1,4-)\n(0,008 – 2,0) mg w próbce (0,67 – 666,7) mg/m3\nKumen (0,008 – 2,0) mg w próbce (0,67 – 666,7) mg/m3\nOktan (0,040 – 10,0) mg w próbce (3,33 – 4000,0) mg/m3\nToluen (0,080 – 2,0) mg w próbce (0,67 – 66,7) mg/m3\nEtanol (0,1 – 10) mg w próbce (3,33 – 3333,3) mg/m3\nIzopentan (0,04 – 10) mg w próbce (3,33 – 6666,7) mg/m3\nPentan (0,04 – 10) mg w próbce (3,33 – 6666,7) mg/m3\nEter tert-butylometylowy (0,008 – 4) mg w próbce (1,33 – 800,0) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Metoda nr 031 Wydanie 5 z dnia 20.02.2026","norm_bases":["Metoda nr 031 Wydanie 5 z dnia 20.02.2026"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość substancji organicznych\nZakres:\nAceton (0,1 – 10) mg w próbce\nZakres (3,33 – 3333,3) mg/m3\nButan-2-on (0,036 – 9,0) mg w próbce (3,00 – 1800,0) mg/m3\nButan (0,78 – 3888,9) mg/m3\n(0,056 – 7,000) mg w próbce Etylobenzen (0,016 – 4,0) mg w próbce (1,33 – 800) mg/m3\nBenzen (0,0015 – 0,15) mg w próbce (0,05 – 5,0) mg/m3\n(0,02 – 1,54) ppm\nHeksan (0,008 – 2,0) mg w próbce (0,67 – 200,0) mg/m3\nCykloheksan (0,028 – 7,0) mg w próbce (2,33 – 2333,3) mg/m3\nMetylocykloheksan (0,040 – 10,0) mg w próbce (3,33 – 6666,7) mg/m3\nHeptan (0,040 – 10,0) mg w próbce (3,33 – 4000,0) mg/m3\nKsylen - mieszanina izomerów (1,2-; 1,3-; 1,4-)\n(0,008 – 2,0) mg w próbce (0,67 – 666,7) mg/m3\nKumen (0,008 – 2,0) mg w próbce (0,67 – 666,7) mg/m3\nOktan (0,040 – 10,0) mg w próbce (3,33 – 4000,0) mg/m3\nToluen (0,080 – 2,0) mg w próbce (0,67 – 66,7) mg/m3\nEtanol (0,1 – 10) mg w próbce (3,33 – 3333,3) mg/m3\nIzopentan (0,04 – 10) mg w próbce (3,33 – 6666,7) mg/m3\nPentan (0,04 – 10) mg w próbce (3,33 – 6666,7) mg/m3\nEter tert-butylometylowy (0,008 – 4) mg w próbce (1,33 – 800,0) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Metoda nr 031 Wydanie 5 z dnia 20.02.2026 Srodowisko pracy − powietrze Stezenie/zawartosc substancji organicznych\nZakres:\nAceton (0,1 – 10) mg w probce\nZakres (3,33 – 3333,3) mg/m3\nButan-2-on (0,036 – 9,0) mg w probce (3,00 – 1800,0) mg/m3\nButan (0,78 – 3888,9) mg/m3\n(0,056 – 7,000) mg w probce Etylobenzen (0,016 – 4,0) mg w probce (1,33 – 800) mg/m3\nBenzen (0,0015 – 0,15) mg w probce (0,05 – 5,0) mg/m3\n(0,02 – 1,54) ppm\nHeksan (0,008 – 2,0) mg w probce (0,67 – 200,0) mg/m3\nCykloheksan (0,028 – 7,0) mg w probce (2,33 – 2333,3) mg/m3\nMetylocykloheksan (0,040 – 10,0) mg w probce (3,33 – 6666,7) mg/m3\nHeptan (0,040 – 10,0) mg w probce (3,33 – 4000,0) mg/m3\nKsylen - mieszanina izomerow (1,2-; 1,3-; 1,4-)\n(0,008 – 2,0) mg w probce (0,67 – 666,7) mg/m3\nKumen (0,008 – 2,0) mg w probce (0,67 – 666,7) mg/m3\nOktan (0,040 – 10,0) mg w probce (3,33 – 4000,0) mg/m3\nToluen (0,080 – 2,0) mg w probce (0,67 – 66,7) mg/m3\nEtanol (0,1 – 10) mg w probce (3,33 – 3333,3) mg/m3\nIzopentan (0,04 – 10) mg w probce (3,33 – 6666,7) mg/m3\nPentan (0,04 – 10) mg w probce (3,33 – 6666,7) mg/m3\nEter tert-butylometylowy (0,008 – 4) mg w probce (1,33 – 800,0) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Metoda nr 031 Wydanie 5 z dnia 20.02.2026","categories":["environment"],"row_index":212,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb61a","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość chloru","parameters":[{"name":"Zakres","range":"(0,05 – 5,00) mg/m3"},{"name":"Zakres","range":"(0,0002 – 0,0050) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość chloru\nZakres:\nZakres (0,05 – 5,00) mg/m3\nZakres (0,0002 – 0,0050) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-75/Z-04037/03","norm_bases":["PN-75/Z-04037/03"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość chloru\nZakres:\nZakres (0,05 – 5,00) mg/m3\nZakres (0,0002 – 0,0050) mg w próbce\nMetoda spektrofotometryczna PN-75/Z-04037/03 Srodowisko pracy − powietrze Stezenie/zawartosc chloru\nZakres:\nZakres (0,05 – 5,00) mg/m3\nZakres (0,0002 – 0,0050) mg w probce\nMetoda spektrofotometryczna PN-75/Z-04037/03","categories":["environment"],"row_index":213,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb61b","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość amoniaku","parameters":[{"name":"Zakres","range":"(1,20 – 60,00) mg/m3"},{"name":"Zakres","range":"(0,006 – 0,300) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość amoniaku\nZakres:\nZakres (1,20 – 60,00) mg/m3\nZakres (0,006 – 0,300) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-71/Z-04041","norm_bases":["PN-71/Z-04041"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość amoniaku\nZakres:\nZakres (1,20 – 60,00) mg/m3\nZakres (0,006 – 0,300) mg w próbce\nMetoda spektrofotometryczna PN-71/Z-04041 Srodowisko pracy − powietrze Stezenie/zawartosc amoniaku\nZakres:\nZakres (1,20 – 60,00) mg/m3\nZakres (0,006 – 0,300) mg w probce\nMetoda spektrofotometryczna PN-71/Z-04041","categories":["environment"],"row_index":214,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb61c","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość fluorowodoru","parameters":[{"name":"Zakres","range":"(0,15 – 2,25) mg/m3"},{"name":"Zakres","range":"(0,008 – 0,113) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość fluorowodoru\nZakres:\nZakres (0,15 – 2,25) mg/m3\nZakres (0,008 – 0,113) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-82/Z-04093.03","norm_bases":["PN-82/Z-04093.03"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość fluorowodoru\nZakres:\nZakres (0,15 – 2,25) mg/m3\nZakres (0,008 – 0,113) mg w próbce\nMetoda spektrofotometryczna PN-82/Z-04093.03 Srodowisko pracy − powietrze Stezenie/zawartosc fluorowodoru\nZakres:\nZakres (0,15 – 2,25) mg/m3\nZakres (0,008 – 0,113) mg w probce\nMetoda spektrofotometryczna PN-82/Z-04093.03","categories":["environment"],"row_index":215,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb61d","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość formaldehydu","parameters":[{"name":"Zakres","range":"(0,048 – 5,33) mg/m3"},{"name":"Zakres","range":"(0,0008 – 0,040) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość formaldehydu\nZakres:\nZakres (0,048 – 5,33) mg/m3\nZakres (0,0008 – 0,040) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-76/Z-04045.02","norm_bases":["PN-76/Z-04045.02"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość formaldehydu\nZakres:\nZakres (0,048 – 5,33) mg/m3\nZakres (0,0008 – 0,040) mg w próbce\nMetoda spektrofotometryczna PN-76/Z-04045.02 Srodowisko pracy − powietrze Stezenie/zawartosc formaldehydu\nZakres:\nZakres (0,048 – 5,33) mg/m3\nZakres (0,0008 – 0,040) mg w probce\nMetoda spektrofotometryczna PN-76/Z-04045.02","categories":["environment"],"row_index":216,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb61e","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość 2-furaldehydu","parameters":[{"name":"Zakres","range":"(1,00 – 50,00) mg/m3"},{"name":"Zakres","range":"(0,005 – 0,250) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość 2-furaldehydu\nZakres:\nZakres (1,00 – 50,00) mg/m3\nZakres (0,005 – 0,250) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-71/Z-04058","norm_bases":["PN-71/Z-04058"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość 2-furaldehydu\nZakres:\nZakres (1,00 – 50,00) mg/m3\nZakres (0,005 – 0,250) mg w próbce\nMetoda spektrofotometryczna PN-71/Z-04058 Srodowisko pracy − powietrze Stezenie/zawartosc 2-furaldehydu\nZakres:\nZakres (1,00 – 50,00) mg/m3\nZakres (0,005 – 0,250) mg w probce\nMetoda spektrofotometryczna PN-71/Z-04058","categories":["environment"],"row_index":217,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb61f","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość ozonu","parameters":[{"name":"Zakres","range":"(0,0125 – 0,3000) mg/m3"},{"name":"Zakres","range":"(0,0005 – 0,0120) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość ozonu\nZakres:\nZakres (0,0125 – 0,3000) mg/m3\nZakres (0,0005 – 0,0120) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-Z-04007-2:1994","norm_bases":["PN-Z-04007-2:1994"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość ozonu\nZakres:\nZakres (0,0125 – 0,3000) mg/m3\nZakres (0,0005 – 0,0120) mg w próbce\nMetoda spektrofotometryczna PN-Z-04007-2:1994 Srodowisko pracy − powietrze Stezenie/zawartosc ozonu\nZakres:\nZakres (0,0125 – 0,3000) mg/m3\nZakres (0,0005 – 0,0120) mg w probce\nMetoda spektrofotometryczna PN-Z-04007-2:1994","categories":["environment"],"row_index":218,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb620","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość tlenku azotu","parameters":[{"name":"Zakres","range":"(0,22 – 23,1) mg/m3"},{"name":"Zakres","range":"(0,18 – 18,6) ppm"},{"name":"Zakres","range":"(0,001 – 0,104) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość tlenku azotu\nZakres:\nZakres (0,22 – 23,1) mg/m3\nZakres (0,18 – 18,6) ppm\nZakres (0,001 – 0,104) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-Z-04009-11:2008","norm_bases":["PN-Z-04009-11:2008"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość tlenku azotu\nZakres:\nZakres (0,22 – 23,1) mg/m3\nZakres (0,18 – 18,6) ppm\nZakres (0,001 – 0,104) mg w próbce\nMetoda spektrofotometryczna PN-Z-04009-11:2008 Srodowisko pracy − powietrze Stezenie/zawartosc tlenku azotu\nZakres:\nZakres (0,22 – 23,1) mg/m3\nZakres (0,18 – 18,6) ppm\nZakres (0,001 – 0,104) mg w probce\nMetoda spektrofotometryczna PN-Z-04009-11:2008","categories":["environment"],"row_index":219,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb621","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość ditlenku azotu","parameters":[{"name":"Zakres","range":"(0,07 – 3,56) mg/m3"},{"name":"Zakres","range":"(0,0003 – 0,016) mg w próbce"},{"name":"Zakres","range":"(0,04 – 1,86) ppm"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość ditlenku azotu\nZakres:\nZakres (0,07 – 3,56) mg/m3\nZakres (0,0003 – 0,016) mg w próbce\nZakres (0,04 – 1,86) ppm\nMetoda spektrofotometryczna","reference":"PN-Z-04009-11:2008","norm_bases":["PN-Z-04009-11:2008"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość ditlenku azotu\nZakres:\nZakres (0,07 – 3,56) mg/m3\nZakres (0,0003 – 0,016) mg w próbce\nZakres (0,04 – 1,86) ppm\nMetoda spektrofotometryczna PN-Z-04009-11:2008 Srodowisko pracy − powietrze Stezenie/zawartosc ditlenku azotu\nZakres:\nZakres (0,07 – 3,56) mg/m3\nZakres (0,0003 – 0,016) mg w probce\nZakres (0,04 – 1,86) ppm\nMetoda spektrofotometryczna PN-Z-04009-11:2008","categories":["environment"],"row_index":220,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb622","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość ditlenku siarki","parameters":[{"name":"Zakres","range":"(0,12 – 6,00) mg/m3"},{"name":"Zakres","range":"(0,0012 – 0,0600) mg w próbce"},{"name":"Zakres","range":"(0,05 – 2,26) ppm"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość ditlenku siarki\nZakres:\nZakres (0,12 – 6,00) mg/m3\nZakres (0,0012 – 0,0600) mg w próbce\nZakres (0,05 – 2,26) ppm\nMetoda spektrofotometryczna","reference":"PN-Z-04015-12:1996+Ap1:2001","norm_bases":["PN-Z-04015-12:1996+Ap1:2001"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość ditlenku siarki\nZakres:\nZakres (0,12 – 6,00) mg/m3\nZakres (0,0012 – 0,0600) mg w próbce\nZakres (0,05 – 2,26) ppm\nMetoda spektrofotometryczna PN-Z-04015-12:1996+Ap1:2001 Srodowisko pracy − powietrze Stezenie/zawartosc ditlenku siarki\nZakres:\nZakres (0,12 – 6,00) mg/m3\nZakres (0,0012 – 0,0600) mg w probce\nZakres (0,05 – 2,26) ppm\nMetoda spektrofotometryczna PN-Z-04015-12:1996+Ap1:2001","categories":["environment"],"row_index":221,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb623","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość disiarczku węgla","parameters":[{"name":"Zakres","range":"(1,0 – 14,0) mg/m3"},{"name":"Zakres","range":"(0,010 – 0,140) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość disiarczku węgla\nZakres:\nZakres (1,0 – 14,0) mg/m3\nZakres (0,010 – 0,140) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-85/Z-04015.10","norm_bases":["PN-85/Z-04015.10"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość disiarczku węgla\nZakres:\nZakres (1,0 – 14,0) mg/m3\nZakres (0,010 – 0,140) mg w próbce\nMetoda spektrofotometryczna PN-85/Z-04015.10 Srodowisko pracy − powietrze Stezenie/zawartosc disiarczku wegla\nZakres:\nZakres (1,0 – 14,0) mg/m3\nZakres (0,010 – 0,140) mg w probce\nMetoda spektrofotometryczna PN-85/Z-04015.10","categories":["environment"],"row_index":222,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb624","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość siarkowodoru","parameters":[{"name":"Zakres","range":"(0,20 – 28,00) mg/m3"},{"name":"Zakres","range":"(0,002 – 0,280) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość siarkowodoru\nZakres:\nZakres (0,20 – 28,00) mg/m3\nZakres (0,002 – 0,280) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-Z-04015-13:1996","norm_bases":["PN-Z-04015-13:1996"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość siarkowodoru\nZakres:\nZakres (0,20 – 28,00) mg/m3\nZakres (0,002 – 0,280) mg w próbce\nMetoda spektrofotometryczna PN-Z-04015-13:1996 Srodowisko pracy − powietrze Stezenie/zawartosc siarkowodoru\nZakres:\nZakres (0,20 – 28,00) mg/m3\nZakres (0,002 – 0,280) mg w probce\nMetoda spektrofotometryczna PN-Z-04015-13:1996","categories":["environment"],"row_index":223,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb625","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość związków chromu (VI) - w przeliczeniu na Cr (VI)","parameters":[{"name":"Zakres","range":"(0,00038 – 0,011) mg/m3"},{"name":"Zakres","range":"(0,0008 – 0,021) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość związków chromu (VI) - w przeliczeniu na Cr (VI)\nZakres:\nZakres (0,00038 – 0,011) mg/m3\nZakres (0,0008 – 0,021) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-87/Z-04126/02","norm_bases":["PN-87/Z-04126/02"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość związków chromu (VI) - w przeliczeniu na Cr (VI)\nZakres:\nZakres (0,00038 – 0,011) mg/m3\nZakres (0,0008 – 0,021) mg w próbce\nMetoda spektrofotometryczna PN-87/Z-04126/02 Srodowisko pracy − powietrze Stezenie/zawartosc zwiazkow chromu (VI) - w przeliczeniu na Cr (VI)\nZakres:\nZakres (0,00038 – 0,011) mg/m3\nZakres (0,0008 – 0,021) mg w probce\nMetoda spektrofotometryczna PN-87/Z-04126/02","categories":["environment"],"row_index":224,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb626","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość kwasu octowego","parameters":[{"name":"Zakres","range":"(0,83 – 100,00) mg/m3"},{"name":"Zakres","range":"(0,025 – 1,500) mg w próbce"},{"name":"Zakres","range":"(0,33 – 40,13) ppm"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość kwasu octowego\nZakres:\nZakres (0,83 – 100,00) mg/m3\nZakres (0,025 – 1,500) mg w próbce\nZakres (0,33 – 40,13) ppm\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04323:2004","norm_bases":["PN-Z-04323:2004"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość kwasu octowego\nZakres:\nZakres (0,83 – 100,00) mg/m3\nZakres (0,025 – 1,500) mg w próbce\nZakres (0,33 – 40,13) ppm\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04323:2004 Srodowisko pracy − powietrze Stezenie/zawartosc kwasu octowego\nZakres:\nZakres (0,83 – 100,00) mg/m3\nZakres (0,025 – 1,500) mg w probce\nZakres (0,33 – 40,13) ppm\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04323:2004","categories":["environment"],"row_index":225,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb627","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość chlorowodoru","parameters":[{"name":"Zakres","range":"(0,50 –20,00) mg/m3"},{"name":"Zakres","range":"(0,20 – 8,00) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość chlorowodoru\nZakres:\nZakres (0,50 –20,00) mg/m3\nZakres (0,20 – 8,00) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-Z-04450:2014-08","norm_bases":["PN-Z-04450:2014-08"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość chlorowodoru\nZakres:\nZakres (0,50 –20,00) mg/m3\nZakres (0,20 – 8,00) mg w próbce\nMetoda spektrofotometryczna PN-Z-04450:2014-08 Srodowisko pracy − powietrze Stezenie/zawartosc chlorowodoru\nZakres:\nZakres (0,50 –20,00) mg/m3\nZakres (0,20 – 8,00) mg w probce\nMetoda spektrofotometryczna PN-Z-04450:2014-08","categories":["environment"],"row_index":226,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb628","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość krystalicznej","parameters":[{"name":"krzemionki (kwarc, krystobalit)"},{"name":"frakcja respirabilna"},{"name":"Zakres","range":"(0,005 – 0,988) mg/m3"},{"name":"Zakres","range":"(0,005 – 0,400) mg w próbce"}],"technique":"Metoda spektrometrii w zakresie podczerwieni z transformacją Fouriera (FT-IR)","techniques":["Metoda spektrometrii w zakresie podczerwieni z transformacją Fouriera (FT-IR)"],"computed":[],"activity":"Stężenie/zawartość krystalicznej\nZakres:\nkrzemionki (kwarc, krystobalit)\nfrakcja respirabilna\nZakres (0,005 – 0,988) mg/m3\nZakres (0,005 – 0,400) mg w próbce\nMetoda spektrometrii w zakresie podczerwieni z transformacją Fouriera (FT-IR)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2012, nr 4(74) s. 117-130","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2012, nr 4(74) s. 117-130"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość krystalicznej\nZakres:\nkrzemionki (kwarc, krystobalit)\nfrakcja respirabilna\nZakres (0,005 – 0,988) mg/m3\nZakres (0,005 – 0,400) mg w próbce\nMetoda spektrometrii w zakresie podczerwieni z transformacją Fouriera (FT-IR) Podstawy i Metody Oceny Środowiska Pracy 2012, nr 4(74) s. 117-130 Srodowisko pracy − powietrze Stezenie/zawartosc krystalicznej\nZakres:\nkrzemionki (kwarc, krystobalit)\nfrakcja respirabilna\nZakres (0,005 – 0,988) mg/m3\nZakres (0,005 – 0,400) mg w probce\nMetoda spektrometrii w zakresie podczerwieni z transformacja Fouriera (FT-IR) Podstawy i Metody Oceny Srodowiska Pracy 2012, nr 4(74) s. 117-130","categories":["environment"],"row_index":227,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb629","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna","parameters":[{"name":"pyły niesklasyfikowane ze względu na toksyczność"},{"name":"pyły drewna"},{"name":"pyły mąki"},{"name":"asfalt naftowy"},{"name":"Zakres","range":"(0,08 – 40,83) mg/m3"},{"name":"Zakres","range":"(0,06 – 2,45) mg w próbce"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie/zawartość pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna\nZakres:\npyły niesklasyfikowane ze względu na toksyczność\npyły drewna\npyły mąki\nasfalt naftowy\nZakres (0,08 – 40,83) mg/m3\nZakres (0,06 – 2,45) mg w próbce\nMetoda grawimetryczna","reference":"PN-Z-04507:2022-05+Ap1:2022-08","norm_bases":["PN-Z-04507:2022-05+Ap1:2022-08"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna\nZakres:\npyły niesklasyfikowane ze względu na toksyczność\npyły drewna\npyły mąki\nasfalt naftowy\nZakres (0,08 – 40,83) mg/m3\nZakres (0,06 – 2,45) mg w próbce\nMetoda grawimetryczna PN-Z-04507:2022-05+Ap1:2022-08 Srodowisko pracy − powietrze Stezenie/zawartosc pylowych czynnikow szkodliwych dla zdrowia - frakcja wdychalna\nZakres:\npyly niesklasyfikowane ze wzgledu na toksycznosc\npyly drewna\npyly maki\nasfalt naftowy\nZakres (0,08 – 40,83) mg/m3\nZakres (0,06 – 2,45) mg w probce\nMetoda grawimetryczna PN-Z-04507:2022-05+Ap1:2022-08","categories":["environment"],"row_index":228,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb62a","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość chloroetenu","parameters":[{"name":"Zakres","range":"(0,11 – 11,11) mg/m3"},{"name":"Zakres","range":"(0,0020 – 0,200) mg w próbce"},{"name":"Zakres","range":"(0,04 – 4,28) ppm"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość chloroetenu\nZakres:\nZakres (0,11 – 11,11) mg/m3\nZakres (0,0020 – 0,200) mg w próbce\nZakres (0,04 – 4,28) ppm\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Metoda 159 Wydanie 3 z dnia 14.12.2020","norm_bases":["Metoda 159 Wydanie 3 z dnia 14.12.2020"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość chloroetenu\nZakres:\nZakres (0,11 – 11,11) mg/m3\nZakres (0,0020 – 0,200) mg w próbce\nZakres (0,04 – 4,28) ppm\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Metoda 159 Wydanie 3 z dnia 14.12.2020 Srodowisko pracy − powietrze Stezenie/zawartosc chloroetenu\nZakres:\nZakres (0,11 – 11,11) mg/m3\nZakres (0,0020 – 0,200) mg w probce\nZakres (0,04 – 4,28) ppm\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Metoda 159 Wydanie 3 z dnia 14.12.2020","categories":["environment"],"row_index":229,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb62b","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość 1,2-dichloroetanu","parameters":[{"name":"Zakres","range":"(0,53 – 55,56) mg/m3"},{"name":"Zakres","range":"(0,010 – 1,000) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość 1,2-dichloroetanu\nZakres:\nZakres (0,53 – 55,56) mg/m3\nZakres (0,010 – 1,000) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Metoda 159 Wydanie 3 z dnia 14.12.2020","norm_bases":["Metoda 159 Wydanie 3 z dnia 14.12.2020"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość 1,2-dichloroetanu\nZakres:\nZakres (0,53 – 55,56) mg/m3\nZakres (0,010 – 1,000) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Metoda 159 Wydanie 3 z dnia 14.12.2020 Srodowisko pracy − powietrze Stezenie/zawartosc 1,2-dichloroetanu\nZakres:\nZakres (0,53 – 55,56) mg/m3\nZakres (0,010 – 1,000) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Metoda 159 Wydanie 3 z dnia 14.12.2020","categories":["environment"],"row_index":230,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb62c","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość tetrachloroetenu","parameters":[{"name":"Zakres","range":"(4,0 – 200) mg/m3"},{"name":"Zakres","range":"(0,040 – 2,00) mg w próbce"},{"name":"Zakres","range":"(0,58 – 29,1) ppm"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość tetrachloroetenu\nZakres:\nZakres (4,0 – 200) mg/m3\nZakres (0,040 – 2,00) mg w próbce\nZakres (0,58 – 29,1) ppm\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Metoda 159 Wydanie 3 z dnia 14.12.2020","norm_bases":["Metoda 159 Wydanie 3 z dnia 14.12.2020"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość tetrachloroetenu\nZakres:\nZakres (4,0 – 200) mg/m3\nZakres (0,040 – 2,00) mg w próbce\nZakres (0,58 – 29,1) ppm\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Metoda 159 Wydanie 3 z dnia 14.12.2020 Srodowisko pracy − powietrze Stezenie/zawartosc tetrachloroetenu\nZakres:\nZakres (4,0 – 200) mg/m3\nZakres (0,040 – 2,00) mg w probce\nZakres (0,58 – 29,1) ppm\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Metoda 159 Wydanie 3 z dnia 14.12.2020","categories":["environment"],"row_index":231,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb62d","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość chloroetanu","parameters":[{"name":"Zakres","range":"(6,67 – 2666,7) mg/m3"},{"name":"Zakres","range":"(0,020 – 2,000) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość chloroetanu\nZakres:\nZakres (6,67 – 2666,7) mg/m3\nZakres (0,020 – 2,000) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Metoda 159 Wydanie 3 z dnia 14.12.2020","norm_bases":["Metoda 159 Wydanie 3 z dnia 14.12.2020"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość chloroetanu\nZakres:\nZakres (6,67 – 2666,7) mg/m3\nZakres (0,020 – 2,000) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Metoda 159 Wydanie 3 z dnia 14.12.2020 Srodowisko pracy − powietrze Stezenie/zawartosc chloroetanu\nZakres:\nZakres (6,67 – 2666,7) mg/m3\nZakres (0,020 – 2,000) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Metoda 159 Wydanie 3 z dnia 14.12.2020","categories":["environment"],"row_index":232,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb62e","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − oświetlenie elektryczne awaryjne","methodology":"Natężenie oświetlenia","parameters":[{"name":"Zakres","range":"(0,5 – 500) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie oświetlenia\nZakres (0,5 – 500) lx\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 1838:2025-05 z wyłączeniem punktów normy 5.1.3, 5.1.4, 5.2.3, 5.2.4, 5.3.4, 5.3.5, 5.3.7, 6.0","norm_bases":["PN-EN 1838:2025-05 z wyłączeniem punktów normy 5.1.3, 5.1.4, 5.2.3, 5.2.4, 5.3.4, 5.3.5, 5.3.7, 6.0"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − oświetlenie elektryczne awaryjne Natężenie oświetlenia\nZakres (0,5 – 500) lx\nMetoda pomiarowa bezpośrednia PN-EN 1838:2025-05 z wyłączeniem punktów normy 5.1.3, 5.1.4, 5.2.3, 5.2.4, 5.3.4, 5.3.5, 5.3.7, 6.0 Srodowisko pracy − oswietlenie elektryczne awaryjne Natezenie oswietlenia\nZakres (0,5 – 500) lx\nMetoda pomiarowa bezposrednia PN-EN 1838:2025-05 z wylaczeniem punktow normy 5.1.3, 5.1.4, 5.2.3, 5.2.4, 5.3.4, 5.3.5, 5.3.7, 6.0","categories":["environment"],"row_index":233,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb62f","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − oświetlenie elektryczne awaryjne","methodology":"Stosunek minimalnego do maksymalnego natężenia oświetlenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stosunek minimalnego do maksymalnego natężenia oświetlenia (z obliczeń)","reference":"PN-EN 1838:2025-05 z wyłączeniem punktów normy 5.1.3, 5.1.4, 5.2.3, 5.2.4, 5.3.4, 5.3.5, 5.3.7, 6.0","norm_bases":["PN-EN 1838:2025-05 z wyłączeniem punktów normy 5.1.3, 5.1.4, 5.2.3, 5.2.4, 5.3.4, 5.3.5, 5.3.7, 6.0"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − oświetlenie elektryczne awaryjne Stosunek minimalnego do maksymalnego natężenia oświetlenia (z obliczeń) PN-EN 1838:2025-05 z wyłączeniem punktów normy 5.1.3, 5.1.4, 5.2.3, 5.2.4, 5.3.4, 5.3.5, 5.3.7, 6.0 Srodowisko pracy − oswietlenie elektryczne awaryjne Stosunek minimalnego do maksymalnego natezenia oswietlenia (z obliczen) PN-EN 1838:2025-05 z wylaczeniem punktow normy 5.1.3, 5.1.4, 5.2.3, 5.2.4, 5.3.4, 5.3.5, 5.3.7, 6.0","categories":["environment"],"row_index":234,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb630","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − oświetlenie elektryczne awaryjne","methodology":"Równomierność oświetlenia dla strefy wysokiego ryzyka (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równomierność oświetlenia dla strefy wysokiego ryzyka (z obliczeń)","reference":"PN-EN 1838:2025-05 z wyłączeniem punktów normy 5.1.3, 5.1.4, 5.2.3, 5.2.4, 5.3.4, 5.3.5, 5.3.7, 6.0","norm_bases":["PN-EN 1838:2025-05 z wyłączeniem punktów normy 5.1.3, 5.1.4, 5.2.3, 5.2.4, 5.3.4, 5.3.5, 5.3.7, 6.0"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − oświetlenie elektryczne awaryjne Równomierność oświetlenia dla strefy wysokiego ryzyka (z obliczeń) PN-EN 1838:2025-05 z wyłączeniem punktów normy 5.1.3, 5.1.4, 5.2.3, 5.2.4, 5.3.4, 5.3.5, 5.3.7, 6.0 Srodowisko pracy − oswietlenie elektryczne awaryjne Rownomiernosc oswietlenia dla strefy wysokiego ryzyka (z obliczen) PN-EN 1838:2025-05 z wylaczeniem punktow normy 5.1.3, 5.1.4, 5.2.3, 5.2.4, 5.3.4, 5.3.5, 5.3.7, 6.0","categories":["environment"],"row_index":235,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb631","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − oświetlenie elektryczne awaryjne","methodology":"Czas załączania","parameters":[{"name":"Zakres","range":"(1 – 80) s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Czas załączania\nZakres (1 – 80) s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 1838:2025-05 z wyłączeniem punktów normy 5.1.3, 5.1.4, 5.2.3, 5.2.4, 5.3.4, 5.3.5, 5.3.7, 6.0","norm_bases":["PN-EN 1838:2025-05 z wyłączeniem punktów normy 5.1.3, 5.1.4, 5.2.3, 5.2.4, 5.3.4, 5.3.5, 5.3.7, 6.0"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − oświetlenie elektryczne awaryjne Czas załączania\nZakres (1 – 80) s\nMetoda pomiarowa bezpośrednia PN-EN 1838:2025-05 z wyłączeniem punktów normy 5.1.3, 5.1.4, 5.2.3, 5.2.4, 5.3.4, 5.3.5, 5.3.7, 6.0 Srodowisko pracy − oswietlenie elektryczne awaryjne Czas zalaczania\nZakres (1 – 80) s\nMetoda pomiarowa bezposrednia PN-EN 1838:2025-05 z wylaczeniem punktow normy 5.1.3, 5.1.4, 5.2.3, 5.2.4, 5.3.4, 5.3.5, 5.3.7, 6.0","categories":["environment"],"row_index":236,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb632","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − oświetlenie elektryczne awaryjne","methodology":"Minimalny czas stosowania oświetlenia","parameters":[{"name":"Zakres","range":"(1 – 3600) s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Minimalny czas stosowania oświetlenia\nZakres (1 – 3600) s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 1838:2025-05 z wyłączeniem punktów normy 5.1.3, 5.1.4, 5.2.3, 5.2.4, 5.3.4, 5.3.5, 5.3.7, 6.0","norm_bases":["PN-EN 1838:2025-05 z wyłączeniem punktów normy 5.1.3, 5.1.4, 5.2.3, 5.2.4, 5.3.4, 5.3.5, 5.3.7, 6.0"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − oświetlenie elektryczne awaryjne Minimalny czas stosowania oświetlenia\nZakres (1 – 3600) s\nMetoda pomiarowa bezpośrednia PN-EN 1838:2025-05 z wyłączeniem punktów normy 5.1.3, 5.1.4, 5.2.3, 5.2.4, 5.3.4, 5.3.5, 5.3.7, 6.0 Srodowisko pracy − oswietlenie elektryczne awaryjne Minimalny czas stosowania oswietlenia\nZakres (1 – 3600) s\nMetoda pomiarowa bezposrednia PN-EN 1838:2025-05 z wylaczeniem punktow normy 5.1.3, 5.1.4, 5.2.3, 5.2.4, 5.3.4, 5.3.5, 5.3.7, 6.0","categories":["environment"],"row_index":237,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb633","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − oświetlenie elektryczne we wnętrzach","methodology":"Natężenie oświetlenia","parameters":[{"name":"Zakres","range":"(5 – 5 000) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie oświetlenia\nZakres (5 – 5 000) lx\nMetoda pomiarowa bezpośrednia","reference":"Metoda 032 wyd. 7 z dnia 19.02.2026","norm_bases":["Metoda 032 wyd. 7 z dnia 19.02.2026"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − oświetlenie elektryczne we wnętrzach Natężenie oświetlenia\nZakres (5 – 5 000) lx\nMetoda pomiarowa bezpośrednia Metoda 032 wyd. 7 z dnia 19.02.2026 Srodowisko pracy − oswietlenie elektryczne we wnetrzach Natezenie oswietlenia\nZakres (5 – 5 000) lx\nMetoda pomiarowa bezposrednia Metoda 032 wyd. 7 z dnia 19.02.2026","categories":["environment"],"row_index":238,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb634","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − oświetlenie elektryczne we wnętrzach","methodology":"Równomierność oświetlenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równomierność oświetlenia (z obliczeń)","reference":"Metoda 032 wyd. 7 z dnia 19.02.2026","norm_bases":["Metoda 032 wyd. 7 z dnia 19.02.2026"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − oświetlenie elektryczne we wnętrzach Równomierność oświetlenia (z obliczeń) Metoda 032 wyd. 7 z dnia 19.02.2026 Srodowisko pracy − oswietlenie elektryczne we wnetrzach Rownomiernosc oswietlenia (z obliczen) Metoda 032 wyd. 7 z dnia 19.02.2026","categories":["environment"],"row_index":239,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb635","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − oświetlenie elektryczne na zewnątrz","methodology":"Natężenie oświetlenia","parameters":[{"name":"Zakres","range":"(5 – 500) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie oświetlenia\nZakres (5 – 500) lx\nMetoda pomiarowa bezpośrednia","reference":"Metoda 032 wyd. 7 z dnia 19.02.2026","norm_bases":["Metoda 032 wyd. 7 z dnia 19.02.2026"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − oświetlenie elektryczne na zewnątrz Natężenie oświetlenia\nZakres (5 – 500) lx\nMetoda pomiarowa bezpośrednia Metoda 032 wyd. 7 z dnia 19.02.2026 Srodowisko pracy − oswietlenie elektryczne na zewnatrz Natezenie oswietlenia\nZakres (5 – 500) lx\nMetoda pomiarowa bezposrednia Metoda 032 wyd. 7 z dnia 19.02.2026","categories":["environment"],"row_index":240,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb636","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − oświetlenie elektryczne na zewnątrz","methodology":"Równomierność oświetlenia (z obliczeń), Zróżnicowanie natężenia oświetlenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równomierność oświetlenia (z obliczeń), Zróżnicowanie natężenia oświetlenia (z obliczeń)","reference":"Metoda 032 wyd. 7 z dnia 19.02.2026","norm_bases":["Metoda 032 wyd. 7 z dnia 19.02.2026"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − oświetlenie elektryczne na zewnątrz Równomierność oświetlenia (z obliczeń), Zróżnicowanie natężenia oświetlenia (z obliczeń) Metoda 032 wyd. 7 z dnia 19.02.2026 Srodowisko pracy − oswietlenie elektryczne na zewnatrz Rownomiernosc oswietlenia (z obliczen), Zroznicowanie natezenia oswietlenia (z obliczen) Metoda 032 wyd. 7 z dnia 19.02.2026","categories":["environment"],"row_index":241,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb637","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − mikroklimat umiarkowany","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(10 – 40) oC"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(10 - 40) oC"},{"name":"Wilgotność powietrza"},{"name":"Zakres","range":"(25 – 75) %"},{"name":"Prędkość powietrza"},{"name":"Zakres","range":"(0,15 – 10) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (10 – 40) oC\nTemperatura poczernionej kuli\nZakres (10 - 40) oC\nWilgotność powietrza\nZakres (25 – 75) %\nPrędkość powietrza\nZakres (0,15 – 10) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7730:2006+Ap1:2014","norm_bases":["PN-EN ISO 7730:2006+Ap1:2014"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − mikroklimat umiarkowany Temperatura powietrza\nZakres:\nZakres (10 – 40) oC\nTemperatura poczernionej kuli\nZakres (10 - 40) oC\nWilgotność powietrza\nZakres (25 – 75) %\nPrędkość powietrza\nZakres (0,15 – 10) m/s\nMetoda pomiarowa bezpośrednia PN-EN ISO 7730:2006+Ap1:2014 Srodowisko pracy − mikroklimat umiarkowany Temperatura powietrza\nZakres:\nZakres (10 – 40) oC\nTemperatura poczernionej kuli\nZakres (10 - 40) oC\nWilgotnosc powietrza\nZakres (25 – 75) %\nPredkosc powietrza\nZakres (0,15 – 10) m/s\nMetoda pomiarowa bezposrednia PN-EN ISO 7730:2006+Ap1:2014","categories":["environment"],"row_index":242,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb638","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − mikroklimat umiarkowany","methodology":"Wskaźnik PMV, Wskaźnik PPD (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik PMV, Wskaźnik PPD (z obliczeń)","reference":"PN-EN ISO 7730:2006+Ap1:2014","norm_bases":["PN-EN ISO 7730:2006+Ap1:2014"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − mikroklimat umiarkowany Wskaźnik PMV, Wskaźnik PPD (z obliczeń) PN-EN ISO 7730:2006+Ap1:2014 Srodowisko pracy − mikroklimat umiarkowany Wskaznik PMV, Wskaznik PPD (z obliczen) PN-EN ISO 7730:2006+Ap1:2014","categories":["environment"],"row_index":243,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb639","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − mikroklimat gorący","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(20 – 40) oC"},{"name":"Temperatura wilgotna naturalna"},{"name":"Zakres","range":"(20 – 40) oC"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(20 – 40) oC"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (20 – 40) oC\nTemperatura wilgotna naturalna\nZakres (20 – 40) oC\nTemperatura poczernionej kuli\nZakres (20 – 40) oC\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7243:2018-01+Ap2:2020-04","norm_bases":["PN-EN ISO 7243:2018-01+Ap2:2020-04"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − mikroklimat gorący Temperatura powietrza\nZakres:\nZakres (20 – 40) oC\nTemperatura wilgotna naturalna\nZakres (20 – 40) oC\nTemperatura poczernionej kuli\nZakres (20 – 40) oC\nMetoda pomiarowa bezpośrednia PN-EN ISO 7243:2018-01+Ap2:2020-04 Srodowisko pracy − mikroklimat goracy Temperatura powietrza\nZakres:\nZakres (20 – 40) oC\nTemperatura wilgotna naturalna\nZakres (20 – 40) oC\nTemperatura poczernionej kuli\nZakres (20 – 40) oC\nMetoda pomiarowa bezposrednia PN-EN ISO 7243:2018-01+Ap2:2020-04","categories":["environment"],"row_index":244,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb63a","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − mikroklimat gorący","methodology":"Wskaźnik WBGT, WBGTeff (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik WBGT, WBGTeff (z obliczeń)","reference":"PN-EN ISO 7243:2018-01+Ap2:2020-04","norm_bases":["PN-EN ISO 7243:2018-01+Ap2:2020-04"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − mikroklimat gorący Wskaźnik WBGT, WBGTeff (z obliczeń) PN-EN ISO 7243:2018-01+Ap2:2020-04 Srodowisko pracy − mikroklimat goracy Wskaznik WBGT, WBGTeff (z obliczen) PN-EN ISO 7243:2018-01+Ap2:2020-04","categories":["environment"],"row_index":245,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb63b","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − drgania o ogólnym działaniu na organizm człowieka","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","parameters":[{"name":"Zakres","range":"(0,10 – 50) m/s2"},{"name":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8 godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników","range":"(1.4awx, 1.4awy, awz)"},{"name":"Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników","range":"(1.4awx, 1.4awy, awz)"},{"name":"(z obliczeń)"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres:\nZakres (0,10 – 50) m/s2\nEkspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8 godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz)\nEkspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz)\n(z obliczeń)\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − drgania o ogólnym działaniu na organizm człowieka Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres:\nZakres (0,10 – 50) m/s2\nEkspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8 godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz)\nEkspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz)\n(z obliczeń)\nMetoda pomiarowa bezpośrednia PN-EN 14253+A1:2011 Srodowisko pracy − drgania o ogolnym dzialaniu na organizm czlowieka Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres:\nZakres (0,10 – 50) m/s2\nEkspozycja dzienna, wyrazona w postaci rownowaznego energetycznie dla 8 godzin dzialania skutecznego, skorygowanego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1.4awx, 1.4awy, awz)\nEkspozycja trwajaca 30 minut i krocej, wyrazona w postaci skutecznego, wazonego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1.4awx, 1.4awy, awz)\n(z obliczen)\nMetoda pomiarowa bezposrednia PN-EN 14253+A1:2011","categories":["environment"],"row_index":246,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb63c","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy - drgania działające na organizm człowieka przez kończyny górne","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","parameters":[{"name":"Zakres","range":"(0,20 – 100) m/s2"},{"name":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8 godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres:\nZakres (0,20 – 100) m/s2\nEkspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8 godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-2:2004/A1:2015-11"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - drgania działające na organizm człowieka przez kończyny górne Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres:\nZakres (0,20 – 100) m/s2\nEkspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8 godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)\nMetoda pomiarowa bezpośrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 Srodowisko pracy - drgania dzialajace na organizm czlowieka przez konczyny gorne Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres:\nZakres (0,20 – 100) m/s2\nEkspozycja dzienna, wyrazona w postaci rownowaznej energetycznie dla 8 godzin dzialania sumy wektorowej skutecznych, skorygowanych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz) Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci sumy wektorowej skutecznych, wazonych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz) (z obliczen)\nMetoda pomiarowa bezposrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","categories":["environment"],"row_index":247,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb63d","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − hałas","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(34 – 139) dB"},{"name":"Szczytowy poziom dźwięku C"},{"name":"Zakres","range":"(34 – 139) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (34 – 139) dB\nSzczytowy poziom dźwięku C\nZakres (34 – 139) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (34 – 139) dB\nSzczytowy poziom dźwięku C\nZakres (34 – 139) dB\nMetoda pomiarowa bezpośrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11 Srodowisko pracy − halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A\nZakres:\nZakres (34 – 139) dB\nSzczytowy poziom dzwieku C\nZakres (34 – 139) dB\nMetoda pomiarowa bezposrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie 2 i 3 – punkt 10 i 11","categories":["environment"],"row_index":248,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb63e","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − hałas","methodology":"Poziom ekspozycji na hałas odniesiony do:","parameters":[{"name":"8-godz. dobowego wymiaru czasu pracy"},{"name":"przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − hałas Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11 Srodowisko pracy − halas Poziom ekspozycji na halas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzecietnego tygodniowego wymiaru czasu pracy (z obliczen) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie 2 i 3 – punkt 10 i 11","categories":["environment"],"row_index":249,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb63f","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy podczas użytkowania systemów elektroenergetycznych i elektrycznych instalacji zasilających prądu przemiennego w energetyce","methodology":"Natężenie pola elektrycznego:","parameters":[{"name":"w zakresie częstotliwości 50 Hz"},{"name":"Zakres","range":"(0,1 – 20) kV/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości 50 Hz\nZakres (0,1 – 20) kV/m\nMetoda pomiarowa bezpośrednia","reference":"Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4(90), s. 91 - 150","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4(90), s. 91 - 150"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (tekst jednolity Dz. U. z 2018 poz. 331).","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy podczas użytkowania systemów elektroenergetycznych i elektrycznych instalacji zasilających prądu przemiennego w energetyce Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości 50 Hz\nZakres (0,1 – 20) kV/m\nMetoda pomiarowa bezpośrednia Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4(90), s. 91 - 150 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy podczas uzytkowania systemow elektroenergetycznych i elektrycznych instalacji zasilajacych pradu przemiennego w energetyce Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci 50 Hz\nZakres (0,1 – 20) kV/m\nMetoda pomiarowa bezposrednia Podstawy i Metody Oceny Srodowiska Pracy 2016, nr 4(90), s. 91 - 150","categories":["environment"],"row_index":250,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb640","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy podczas użytkowania systemów elektroenergetycznych i elektrycznych instalacji zasilających prądu przemiennego w energetyce","methodology":"Indukcja magnetyczna:","parameters":[{"name":"w zakresie częstotliwości 50 Hz"},{"name":"Zakres","range":"1 μT – 10 mT"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Indukcja magnetyczna:\nZakres:\nw zakresie częstotliwości 50 Hz\nZakres 1 μT – 10 mT\nMetoda pomiarowa bezpośrednia","reference":"Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4(90), s. 91 - 150","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4(90), s. 91 - 150"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (tekst jednolity Dz. U. z 2018 poz. 331).","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy podczas użytkowania systemów elektroenergetycznych i elektrycznych instalacji zasilających prądu przemiennego w energetyce Indukcja magnetyczna:\nZakres:\nw zakresie częstotliwości 50 Hz\nZakres 1 μT – 10 mT\nMetoda pomiarowa bezpośrednia Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4(90), s. 91 - 150 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy podczas uzytkowania systemow elektroenergetycznych i elektrycznych instalacji zasilajacych pradu przemiennego w energetyce Indukcja magnetyczna:\nZakres:\nw zakresie czestotliwosci 50 Hz\nZakres 1 μT – 10 mT\nMetoda pomiarowa bezposrednia Podstawy i Metody Oceny Srodowiska Pracy 2016, nr 4(90), s. 91 - 150","categories":["environment"],"row_index":251,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb641","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy podczas użytkowania systemów elektroenergetycznych i elektrycznych instalacji zasilających prądu przemiennego w energetyce","methodology":"Natężenie pole magnetycznego o częstotliwości 50 Hz (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pole magnetycznego o częstotliwości 50 Hz (z obliczeń)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4(90), s. 91 - 150","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4(90), s. 91 - 150"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (tekst jednolity Dz. U. z 2018 poz. 331).","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy podczas użytkowania systemów elektroenergetycznych i elektrycznych instalacji zasilających prądu przemiennego w energetyce Natężenie pole magnetycznego o częstotliwości 50 Hz (z obliczeń) Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4(90), s. 91 - 150 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy podczas uzytkowania systemow elektroenergetycznych i elektrycznych instalacji zasilajacych pradu przemiennego w energetyce Natezenie pole magnetycznego o czestotliwosci 50 Hz (z obliczen) Podstawy i Metody Oceny Srodowiska Pracy 2016, nr 4(90), s. 91 - 150","categories":["environment"],"row_index":252,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb642","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość związków niklu w przeliczeniu na Ni – frakcja wdychalna","parameters":[{"name":"Zakres","range":"(0,0009 – 0,16) mg/m3"},{"name":"Zakres","range":"(0,001 – 0,12) mg w próbce"},{"name":"– frakcja respirabilna"},{"name":"Zakres","range":"(0,0006 – 0,11) mg/m3"},{"name":"Zakres","range":"(0,001 – 0,12) mg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie/zawartość związków niklu w przeliczeniu na Ni – frakcja wdychalna\nZakres:\nZakres (0,0009 – 0,16) mg/m3\nZakres (0,001 – 0,12) mg w próbce\n– frakcja respirabilna\nZakres (0,0006 – 0,11) mg/m3\nZakres (0,001 – 0,12) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2021, nr4(110), s. 179-189","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2021, nr4(110), s. 179-189"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość związków niklu w przeliczeniu na Ni – frakcja wdychalna\nZakres:\nZakres (0,0009 – 0,16) mg/m3\nZakres (0,001 – 0,12) mg w próbce\n– frakcja respirabilna\nZakres (0,0006 – 0,11) mg/m3\nZakres (0,001 – 0,12) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) Podstawy i Metody Oceny Środowiska Pracy 2021, nr4(110), s. 179-189 Srodowisko pracy − powietrze Stezenie/zawartosc zwiazkow niklu w przeliczeniu na Ni – frakcja wdychalna\nZakres:\nZakres (0,0009 – 0,16) mg/m3\nZakres (0,001 – 0,12) mg w probce\n– frakcja respirabilna\nZakres (0,0006 – 0,11) mg/m3\nZakres (0,001 – 0,12) mg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) Podstawy i Metody Oceny Srodowiska Pracy 2021, nr4(110), s. 179-189","categories":["environment"],"row_index":253,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb643","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość niklu metalicznego","parameters":[{"name":"Zakres","range":"(0,014 – 0,55) mg/m3"},{"name":"Zakres","range":"(0,010 – 0,400) mg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie/zawartość niklu metalicznego\nZakres:\nZakres (0,014 – 0,55) mg/m3\nZakres (0,010 – 0,400) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04502:2019-10","norm_bases":["PN-Z-04502:2019-10"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość niklu metalicznego\nZakres:\nZakres (0,014 – 0,55) mg/m3\nZakres (0,010 – 0,400) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04502:2019-10 Srodowisko pracy − powietrze Stezenie/zawartosc niklu metalicznego\nZakres:\nZakres (0,014 – 0,55) mg/m3\nZakres (0,010 – 0,400) mg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04502:2019-10","categories":["materials","environment"],"row_index":254,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb644","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość ołowiu i jego związków nieorganicznych, z wyjątkiem arsenianu (V) ołowiu (II) oraz chromianu (VI) ołowiu (II) w przeliczeniu na Pb","parameters":[{"name":"frakcja wdychalna"},{"name":"Zakres","range":"(0,0035 – 0,185) mg/m3"},{"name":"Zakres","range":"(0,0025 – 0,100) mg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie/zawartość ołowiu i jego związków nieorganicznych, z wyjątkiem arsenianu (V) ołowiu (II) oraz chromianu (VI) ołowiu (II) w przeliczeniu na Pb\nZakres:\nfrakcja wdychalna\nZakres (0,0035 – 0,185) mg/m3\nZakres (0,0025 – 0,100) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04487:2017-10","norm_bases":["PN-Z-04487:2017-10"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość ołowiu i jego związków nieorganicznych, z wyjątkiem arsenianu (V) ołowiu (II) oraz chromianu (VI) ołowiu (II) w przeliczeniu na Pb\nZakres:\nfrakcja wdychalna\nZakres (0,0035 – 0,185) mg/m3\nZakres (0,0025 – 0,100) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04487:2017-10 Srodowisko pracy − powietrze Stezenie/zawartosc olowiu i jego zwiazkow nieorganicznych, z wyjatkiem arsenianu (V) olowiu (II) oraz chromianu (VI) olowiu (II) w przeliczeniu na Pb\nZakres:\nfrakcja wdychalna\nZakres (0,0035 – 0,185) mg/m3\nZakres (0,0025 – 0,100) mg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04487:2017-10","categories":["environment"],"row_index":255,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb645","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość manganu i jego związków nieorganicznych w przeliczeniu na Mn","parameters":[{"name":"frakcja wdychalna"},{"name":"Zakres","range":"(0,008 – 0,444) mg/m3"},{"name":"Zakres","range":"(0,006 – 0,320) mg w próbce"},{"name":"frakcja respirabilna"},{"name":"Zakres","range":"(0,001 – 0,148) mg/m3"},{"name":"Zakres","range":"(0,0015 – 0,1600) mg w próbce"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie/zawartość manganu i jego związków nieorganicznych w przeliczeniu na Mn\nZakres:\nfrakcja wdychalna\nZakres (0,008 – 0,444) mg/m3\nZakres (0,006 – 0,320) mg w próbce\nfrakcja respirabilna\nZakres (0,001 – 0,148) mg/m3\nZakres (0,0015 – 0,1600) mg w próbce\nMetoda absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04472:2015-10+Ap:1:2015-12","norm_bases":["PN-Z-04472:2015-10+Ap:1:2015-12"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość manganu i jego związków nieorganicznych w przeliczeniu na Mn\nZakres:\nfrakcja wdychalna\nZakres (0,008 – 0,444) mg/m3\nZakres (0,006 – 0,320) mg w próbce\nfrakcja respirabilna\nZakres (0,001 – 0,148) mg/m3\nZakres (0,0015 – 0,1600) mg w próbce\nMetoda absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04472:2015-10+Ap:1:2015-12 Srodowisko pracy − powietrze Stezenie/zawartosc manganu i jego zwiazkow nieorganicznych w przeliczeniu na Mn\nZakres:\nfrakcja wdychalna\nZakres (0,008 – 0,444) mg/m3\nZakres (0,006 – 0,320) mg w probce\nfrakcja respirabilna\nZakres (0,001 – 0,148) mg/m3\nZakres (0,0015 – 0,1600) mg w probce\nMetoda absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04472:2015-10+Ap:1:2015-12","categories":["environment"],"row_index":256,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb646","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość chromu metalicznego, związków chromu: chrom (II), chrom (III), chrom (VI) – w przeliczeniu na Cr","parameters":[{"name":"Zakres","range":"(0,017 – 1,389) mg/m3"},{"name":"Zakres","range":"(0,012 – 1,000) mg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie/zawartość chromu metalicznego, związków chromu: chrom (II), chrom (III), chrom (VI) – w przeliczeniu na Cr\nZakres:\nZakres (0,017 – 1,389) mg/m3\nZakres (0,012 – 1,000) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04434:2011","norm_bases":["PN-Z-04434:2011"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość chromu metalicznego, związków chromu: chrom (II), chrom (III), chrom (VI) – w przeliczeniu na Cr\nZakres:\nZakres (0,017 – 1,389) mg/m3\nZakres (0,012 – 1,000) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04434:2011 Srodowisko pracy − powietrze Stezenie/zawartosc chromu metalicznego, zwiazkow chromu: chrom (II), chrom (III), chrom (VI) – w przeliczeniu na Cr\nZakres:\nZakres (0,017 – 1,389) mg/m3\nZakres (0,012 – 1,000) mg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04434:2011","categories":["materials","environment"],"row_index":257,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb647","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość tlenków żelaza w przeliczeniu na Fe tlenek żelaza (III) tlenek żelaza (II) tetratlenek triżelaza","parameters":[{"name":"frakcja respirabilna"},{"name":"Zakres","range":"(0,23 – 6,94) mg/m3"},{"name":"Zakres","range":"(0,125 – 3,750) mg w próbce"},{"name":"frakcja wdychalna"},{"name":"Zakres","range":"(0,35 – 10,42) mg/m3"},{"name":"Zakres","range":"(0,25 – 7,50) mg w próbce"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie/zawartość tlenków żelaza w przeliczeniu na Fe tlenek żelaza (III) tlenek żelaza (II) tetratlenek triżelaza\nZakres:\nfrakcja respirabilna\nZakres (0,23 – 6,94) mg/m3\nZakres (0,125 – 3,750) mg w próbce\nfrakcja wdychalna\nZakres (0,35 – 10,42) mg/m3\nZakres (0,25 – 7,50) mg w próbce\nMetoda absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04469:2025-02","norm_bases":["PN-Z-04469:2025-02"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość tlenków żelaza w przeliczeniu na Fe tlenek żelaza (III) tlenek żelaza (II) tetratlenek triżelaza\nZakres:\nfrakcja respirabilna\nZakres (0,23 – 6,94) mg/m3\nZakres (0,125 – 3,750) mg w próbce\nfrakcja wdychalna\nZakres (0,35 – 10,42) mg/m3\nZakres (0,25 – 7,50) mg w próbce\nMetoda absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04469:2025-02 Srodowisko pracy − powietrze Stezenie/zawartosc tlenkow zelaza w przeliczeniu na Fe tlenek zelaza (III) tlenek zelaza (II) tetratlenek trizelaza\nZakres:\nfrakcja respirabilna\nZakres (0,23 – 6,94) mg/m3\nZakres (0,125 – 3,750) mg w probce\nfrakcja wdychalna\nZakres (0,35 – 10,42) mg/m3\nZakres (0,25 – 7,50) mg w probce\nMetoda absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04469:2025-02","categories":["environment"],"row_index":258,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb648","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość wodorotlenku potasu","parameters":[{"name":"Zakres","range":"(0,02 –2,00) mg/m3"},{"name":"Zakres","range":"(0,014 –1,435) mg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie/zawartość wodorotlenku potasu\nZakres:\nZakres (0,02 –2,00) mg/m3\nZakres (0,014 –1,435) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04436:2011","norm_bases":["PN-Z-04436:2011"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość wodorotlenku potasu\nZakres:\nZakres (0,02 –2,00) mg/m3\nZakres (0,014 –1,435) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04436:2011 Srodowisko pracy − powietrze Stezenie/zawartosc wodorotlenku potasu\nZakres:\nZakres (0,02 –2,00) mg/m3\nZakres (0,014 –1,435) mg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04436:2011","categories":["environment"],"row_index":259,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb649","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość wodorotlenku sodu","parameters":[{"name":"Zakres","range":"(0,012 – 2,420) mg/m3"},{"name":"Zakres","range":"(0,0087 – 1,7400) mg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie/zawartość wodorotlenku sodu\nZakres:\nZakres (0,012 – 2,420) mg/m3\nZakres (0,0087 – 1,7400) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04435:2011","norm_bases":["PN-Z-04435:2011"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość wodorotlenku sodu\nZakres:\nZakres (0,012 – 2,420) mg/m3\nZakres (0,0087 – 1,7400) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04435:2011 Srodowisko pracy − powietrze Stezenie/zawartosc wodorotlenku sodu\nZakres:\nZakres (0,012 – 2,420) mg/m3\nZakres (0,0087 – 1,7400) mg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04435:2011","categories":["environment"],"row_index":260,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb64a","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość kobaltu i jego związków nieorganicznych w przeliczeniu na Co","parameters":[{"name":"Zakres","range":"(0,002 – 0,042) mg/m3"},{"name":"Zakres","range":"(0,0013 – 0,0300) mg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie/zawartość kobaltu i jego związków nieorganicznych w przeliczeniu na Co\nZakres:\nZakres (0,002 – 0,042) mg/m3\nZakres (0,0013 – 0,0300) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04291:2003","norm_bases":["PN-Z-04291:2003"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość kobaltu i jego związków nieorganicznych w przeliczeniu na Co\nZakres:\nZakres (0,002 – 0,042) mg/m3\nZakres (0,0013 – 0,0300) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04291:2003 Srodowisko pracy − powietrze Stezenie/zawartosc kobaltu i jego zwiazkow nieorganicznych w przeliczeniu na Co\nZakres:\nZakres (0,002 – 0,042) mg/m3\nZakres (0,0013 – 0,0300) mg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04291:2003","categories":["environment"],"row_index":261,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb64b","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Liczba oktanowa motorowa (MON) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Liczba oktanowa motorowa (MON) (z obliczeń)","reference":"PN-EN 589:2024-08 załącznik B","norm_bases":["PN-EN 589:2024-08 załącznik B"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Liczba oktanowa motorowa (MON) (z obliczeń) PN-EN 589:2024-08 załącznik B Paliwa gazowe: skroplone gazy weglowodorowe, LPG Liczba oktanowa motorowa (MON) (z obliczen) PN-EN 589:2024-08 zalacznik B","categories":["petro"],"row_index":262,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb64c","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Całkowita zawartość siarki","parameters":[{"name":"Zakres","range":"(1,0 – 55,0) mg/kg"},{"name":"Zakres","range":"(0,0001 – 0,0055) %(m/m)"}],"technique":"Metoda fluorescencji w nadfiolecie","techniques":["Metoda fluorescencji w nadfiolecie"],"computed":[],"activity":"Całkowita zawartość siarki\nZakres:\nZakres (1,0 – 55,0) mg/kg\nZakres (0,0001 – 0,0055) %(m/m)\nMetoda fluorescencji w nadfiolecie","reference":"ASTM D 6667-21","norm_bases":["ASTM D 6667-21"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Całkowita zawartość siarki\nZakres:\nZakres (1,0 – 55,0) mg/kg\nZakres (0,0001 – 0,0055) %(m/m)\nMetoda fluorescencji w nadfiolecie ASTM D 6667-21 Paliwa gazowe: skroplone gazy weglowodorowe, LPG Calkowita zawartosc siarki\nZakres:\nZakres (1,0 – 55,0) mg/kg\nZakres (0,0001 – 0,0055) %(m/m)\nMetoda fluorescencji w nadfiolecie ASTM D 6667-21","categories":["petro"],"row_index":263,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb64d","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Prężność par oszacowana w temperaturze 40 oC (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Prężność par oszacowana w temperaturze 40 oC (z obliczeń)","reference":"PN-EN ISO 8973:2000+A1:2020-10 | PN-EN 589:2024-08 załącznik C","norm_bases":["PN-EN ISO 8973:2000+A1:2020-10","PN-EN 589:2024-08 załącznik C"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Prężność par oszacowana w temperaturze 40 oC (z obliczeń) PN-EN ISO 8973:2000+A1:2020-10 | PN-EN 589:2024-08 załącznik C Paliwa gazowe: skroplone gazy weglowodorowe, LPG Preznosc par oszacowana w temperaturze 40 oC (z obliczen) PN-EN ISO 8973:2000+A1:2020-10 | PN-EN 589:2024-08 zalacznik C","categories":["petro"],"row_index":264,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb64e","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Temperatura, w której oszacowana względna prężność par jest nie mniejsza niż 150 kPa (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura, w której oszacowana względna prężność par jest nie mniejsza niż 150 kPa (z obliczeń)","reference":"PN-EN ISO 8973:2000+A1:2020-10 | PN-EN 589:2019-04 załącznik C","norm_bases":["PN-EN ISO 8973:2000+A1:2020-10","PN-EN 589:2019-04 załącznik C"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Temperatura, w której oszacowana względna prężność par jest nie mniejsza niż 150 kPa (z obliczeń) PN-EN ISO 8973:2000+A1:2020-10 | PN-EN 589:2019-04 załącznik C Paliwa gazowe: skroplone gazy weglowodorowe, LPG Temperatura, w ktorej oszacowana wzgledna preznosc par jest nie mniejsza niz 150 kPa (z obliczen) PN-EN ISO 8973:2000+A1:2020-10 | PN-EN 589:2019-04 zalacznik C","categories":["petro"],"row_index":265,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb64f","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Prężność par oszacowana w temperaturze (-10)°C, (-5)°C, 0°C, 10°C, 20°C (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Prężność par oszacowana w temperaturze (-10)°C, (-5)°C, 0°C, 10°C, 20°C (z obliczeń)","reference":"PN-EN ISO 8973:2000+A1:2020-10 | PN-EN 589:2024-08 załącznik C","norm_bases":["PN-EN ISO 8973:2000+A1:2020-10","PN-EN 589:2024-08 załącznik C"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Prężność par oszacowana w temperaturze (-10)°C, (-5)°C, 0°C, 10°C, 20°C (z obliczeń) PN-EN ISO 8973:2000+A1:2020-10 | PN-EN 589:2024-08 załącznik C Paliwa gazowe: skroplone gazy weglowodorowe, LPG Preznosc par oszacowana w temperaturze (-10)°C, (-5)°C, 0°C, 10°C, 20°C (z obliczen) PN-EN ISO 8973:2000+A1:2020-10 | PN-EN 589:2024-08 zalacznik C","categories":["petro"],"row_index":266,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb650","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Skład węglowodorowy","parameters":[{"name":"Zakres","range":"(0,1 – 100,0) %(m/m)"},{"name":"Zakres","range":"(0,1 – 100,0) %(mol)"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Skład węglowodorowy\nZakres:\nZakres (0,1 – 100,0) %(m/m)\nZakres (0,1 – 100,0) %(mol)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-ISO 7941:1993+Ap1:2002 | PN-EN 27941:2015-12","norm_bases":["PN-ISO 7941:1993+Ap1:2002","PN-EN 27941:2015-12"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Skład węglowodorowy\nZakres:\nZakres (0,1 – 100,0) %(m/m)\nZakres (0,1 – 100,0) %(mol)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-ISO 7941:1993+Ap1:2002 | PN-EN 27941:2015-12 Paliwa gazowe: skroplone gazy weglowodorowe, LPG Sklad weglowodorowy\nZakres:\nZakres (0,1 – 100,0) %(m/m)\nZakres (0,1 – 100,0) %(mol)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-ISO 7941:1993+Ap1:2002 | PN-EN 27941:2015-12","categories":["petro"],"row_index":267,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb651","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Całkowita zawartość dienów","parameters":[{"name":"Zakres","range":"(0,1 – 2,1) %(m/m)"},{"name":"Zakres","range":"(0,1 – 2,0) %(mol)"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Całkowita zawartość dienów\nZakres:\nZakres (0,1 – 2,1) %(m/m)\nZakres (0,1 – 2,0) %(mol)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-ISO 7941:1993+Ap1:2002 | PN-EN 27941:2015-12","norm_bases":["PN-ISO 7941:1993+Ap1:2002","PN-EN 27941:2015-12"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Całkowita zawartość dienów\nZakres:\nZakres (0,1 – 2,1) %(m/m)\nZakres (0,1 – 2,0) %(mol)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-ISO 7941:1993+Ap1:2002 | PN-EN 27941:2015-12 Paliwa gazowe: skroplone gazy weglowodorowe, LPG Calkowita zawartosc dienow\nZakres:\nZakres (0,1 – 2,1) %(m/m)\nZakres (0,1 – 2,0) %(mol)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-ISO 7941:1993+Ap1:2002 | PN-EN 27941:2015-12","categories":["petro"],"row_index":268,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb652","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Działanie korodujące na miedź","parameters":[{"name":"klasa korozji","range":"(1 – 4)"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Działanie korodujące na miedź\nklasa korozji (1 – 4)\nMetoda wizualna","reference":"PN-EN ISO 6251:2001","norm_bases":["PN-EN ISO 6251:2001"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Działanie korodujące na miedź\nklasa korozji (1 – 4)\nMetoda wizualna PN-EN ISO 6251:2001 Paliwa gazowe: skroplone gazy weglowodorowe, LPG Dzialanie korodujace na miedz\nklasa korozji (1 – 4)\nMetoda wizualna PN-EN ISO 6251:2001","categories":["petro","materials"],"row_index":269,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb653","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Obecność siarkowodoru","parameters":[],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Obecność siarkowodoru\nMetoda wizualna","reference":"PN-EN ISO 8819:2000","norm_bases":["PN-EN ISO 8819:2000"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Obecność siarkowodoru\nMetoda wizualna PN-EN ISO 8819:2000 Paliwa gazowe: skroplone gazy weglowodorowe, LPG Obecnosc siarkowodoru\nMetoda wizualna PN-EN ISO 8819:2000","categories":["petro"],"row_index":270,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb654","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Obecność wody","parameters":[],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Obecność wody\nMetoda wizualna","reference":"PN-EN 15469:2009","norm_bases":["PN-EN 15469:2009"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Obecność wody\nMetoda wizualna PN-EN 15469:2009 Paliwa gazowe: skroplone gazy weglowodorowe, LPG Obecnosc wody\nMetoda wizualna PN-EN 15469:2009","categories":["petro","water"],"row_index":271,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb655","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Zapach","parameters":[],"technique":"Metoda organoleptyczna","techniques":["Metoda organoleptyczna"],"computed":[],"activity":"Zapach\nMetoda organoleptyczna","reference":"PN-EN 589:2024-08 załącznik A","norm_bases":["PN-EN 589:2024-08 załącznik A"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Zapach\nMetoda organoleptyczna PN-EN 589:2024-08 załącznik A Paliwa gazowe: skroplone gazy weglowodorowe, LPG Zapach\nMetoda organoleptyczna PN-EN 589:2024-08 zalacznik A","categories":["petro"],"row_index":272,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb656","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Wartość opałowa (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wartość opałowa (z obliczeń)","reference":"PN-C-96008:1998 p. 4.4.8","norm_bases":["PN-C-96008:1998 p. 4.4.8"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Wartość opałowa (z obliczeń) PN-C-96008:1998 p. 4.4.8 Paliwa gazowe: skroplone gazy weglowodorowe, LPG Wartosc opalowa (z obliczen) PN-C-96008:1998 p. 4.4.8","categories":["petro"],"row_index":273,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb657","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Prężność absolutna par w temp. (-15) °C (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Prężność absolutna par w temp. (-15) °C (z obliczeń)","reference":"PN-C-96008:1998 p. 4.4.10","norm_bases":["PN-C-96008:1998 p. 4.4.10"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Prężność absolutna par w temp. (-15) °C (z obliczeń) PN-C-96008:1998 p. 4.4.10 Paliwa gazowe: skroplone gazy weglowodorowe, LPG Preznosc absolutna par w temp. (-15) °C (z obliczen) PN-C-96008:1998 p. 4.4.10","categories":["petro"],"row_index":274,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb658","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Prężność absolutna par w temp. 40 °C (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Prężność absolutna par w temp. 40 °C (z obliczeń)","reference":"PN-C-96008:1998 p. 4.4.10","norm_bases":["PN-C-96008:1998 p. 4.4.10"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Prężność absolutna par w temp. 40 °C (z obliczeń) PN-C-96008:1998 p. 4.4.10 Paliwa gazowe: skroplone gazy weglowodorowe, LPG Preznosc absolutna par w temp. 40 °C (z obliczen) PN-C-96008:1998 p. 4.4.10","categories":["petro"],"row_index":275,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb659","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Prężność absolutna par w temp. 70 °C (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Prężność absolutna par w temp. 70 °C (z obliczeń)","reference":"PN-C-96008:1998 p. 4.4.10","norm_bases":["PN-C-96008:1998 p. 4.4.10"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Prężność absolutna par w temp. 70 °C (z obliczeń) PN-C-96008:1998 p. 4.4.10 Paliwa gazowe: skroplone gazy weglowodorowe, LPG Preznosc absolutna par w temp. 70 °C (z obliczen) PN-C-96008:1998 p. 4.4.10","categories":["petro"],"row_index":276,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb65a","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Gęstość w temp. 15,6 °C (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Gęstość w temp. 15,6 °C (z obliczeń)","reference":"PN-C-96008:1998 p. 4.4.9","norm_bases":["PN-C-96008:1998 p. 4.4.9"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Gęstość w temp. 15,6 °C (z obliczeń) PN-C-96008:1998 p. 4.4.9 Paliwa gazowe: skroplone gazy weglowodorowe, LPG Gestosc w temp. 15,6 °C (z obliczen) PN-C-96008:1998 p. 4.4.9","categories":["petro"],"row_index":277,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb65b","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Rozpuszczalna pozostałość","parameters":[{"name":"Zakres","range":"(5 – 100) mg/kg"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Rozpuszczalna pozostałość\nZakres (5 – 100) mg/kg\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 15470:2017-08","norm_bases":["PN-EN 15470:2017-08"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Rozpuszczalna pozostałość\nZakres (5 – 100) mg/kg\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 15470:2017-08 Paliwa gazowe: skroplone gazy weglowodorowe, LPG Rozpuszczalna pozostalosc\nZakres (5 – 100) mg/kg\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 15470:2017-08","categories":["petro"],"row_index":278,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb65c","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Całkowita zawartość dienów","parameters":[{"name":"Zakres","range":"(0,01 – 0,50) %(m/m)"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Całkowita zawartość dienów\nZakres (0,01 – 0,50) %(m/m)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"DIN 51619:2004-02","norm_bases":["DIN 51619:2004-02"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Całkowita zawartość dienów\nZakres (0,01 – 0,50) %(m/m)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) DIN 51619:2004-02 Paliwa gazowe: skroplone gazy weglowodorowe, LPG Calkowita zawartosc dienow\nZakres (0,01 – 0,50) %(m/m)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) DIN 51619:2004-02","categories":["petro"],"row_index":279,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb65d","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Zawartość 1,3 butadienu","parameters":[{"name":"Zakres","range":"(0,01 – 0,50) %(m/m)"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość 1,3 butadienu\nZakres (0,01 – 0,50) %(m/m)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"DIN 51619:2004-02","norm_bases":["DIN 51619:2004-02"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Zawartość 1,3 butadienu\nZakres (0,01 – 0,50) %(m/m)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) DIN 51619:2004-02 Paliwa gazowe: skroplone gazy weglowodorowe, LPG Zawartosc 1,3 butadienu\nZakres (0,01 – 0,50) %(m/m)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) DIN 51619:2004-02","categories":["petro"],"row_index":280,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb65e","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Skład węglowodorowy","parameters":[{"name":"Zakres","range":"(0,10 – 100,00) %(m/m) dla"},{"name":"każdego ze składników"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Skład węglowodorowy\nZakres:\nZakres (0,10 – 100,00) %(m/m) dla\nkażdego ze składników\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"DIN 51619:2004-02","norm_bases":["DIN 51619:2004-02"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Skład węglowodorowy\nZakres:\nZakres (0,10 – 100,00) %(m/m) dla\nkażdego ze składników\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) DIN 51619:2004-02 Paliwa gazowe: skroplone gazy weglowodorowe, LPG Sklad weglowodorowy\nZakres:\nZakres (0,10 – 100,00) %(m/m) dla\nkazdego ze skladnikow\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) DIN 51619:2004-02","categories":["petro"],"row_index":281,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb65f","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe","methodology":"Obecność siarkowodoru","parameters":[],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Obecność siarkowodoru\nMetoda wizualna","reference":"PN-C-96008:1998 p. 4.4.2","norm_bases":["PN-C-96008:1998 p. 4.4.2"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe Obecność siarkowodoru\nMetoda wizualna PN-C-96008:1998 p. 4.4.2 Paliwa gazowe: skroplone gazy weglowodorowe Obecnosc siarkowodoru\nMetoda wizualna PN-C-96008:1998 p. 4.4.2","categories":["petro"],"row_index":282,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb660","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe","methodology":"Zawartość oleju mineralnego","parameters":[{"name":"Zakres","range":"(0,0003 – 0,0050) %(m/m)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość oleju mineralnego\nZakres (0,0003 – 0,0050) %(m/m)\nMetoda wagowa","reference":"PN-C-96008:1998 p. 4.4.4","norm_bases":["PN-C-96008:1998 p. 4.4.4"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe Zawartość oleju mineralnego\nZakres (0,0003 – 0,0050) %(m/m)\nMetoda wagowa PN-C-96008:1998 p. 4.4.4 Paliwa gazowe: skroplone gazy weglowodorowe Zawartosc oleju mineralnego\nZakres (0,0003 – 0,0050) %(m/m)\nMetoda wagowa PN-C-96008:1998 p. 4.4.4","categories":["petro"],"row_index":283,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb661","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe","methodology":"Obecność wody","parameters":[],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Obecność wody\nMetoda wizualna","reference":"PN-C-96008:1998 p. 4.4.5","norm_bases":["PN-C-96008:1998 p. 4.4.5"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe Obecność wody\nMetoda wizualna PN-C-96008:1998 p. 4.4.5 Paliwa gazowe: skroplone gazy weglowodorowe Obecnosc wody\nMetoda wizualna PN-C-96008:1998 p. 4.4.5","categories":["water","petro"],"row_index":284,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb662","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe","methodology":"Obecność amoniaku","parameters":[],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Obecność amoniaku\nMetoda wizualna","reference":"PN-C-96008:1998 p. 4.4.6","norm_bases":["PN-C-96008:1998 p. 4.4.6"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe Obecność amoniaku\nMetoda wizualna PN-C-96008:1998 p. 4.4.6 Paliwa gazowe: skroplone gazy weglowodorowe Obecnosc amoniaku\nMetoda wizualna PN-C-96008:1998 p. 4.4.6","categories":["petro"],"row_index":285,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb663","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: gazy z procesów technologicznych: gazy opałowe, gazy wodorowe, gazy pooksydacyjne, gazy węglowodorowe","methodology":"Skład szczegółowy","parameters":[{"name":"Węglowodory od C1 do C6"},{"name":"Zakres","range":"(0,10 – 99,90) % (mol/mol)"},{"name":"Tlen","range":"(0,10 – 20,00) %(mol/mol)"},{"name":"Azot","range":"(0,10 – 90,00) %(mol/mol)"},{"name":"CO2","range":"(0,10 – 45,00) %(mol/mol)"},{"name":"CO","range":"(0,10 – 1,00) %(mol/mol)"},{"name":"H2","range":"(0,10 – 99,70) %(mol/mol)"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną i termokonduktometryczną (GC-FID/TCD)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną i termokonduktometryczną (GC-FID/TCD)"],"computed":[],"activity":"Skład szczegółowy\nZakres:\nWęglowodory od C1 do C6\nZakres (0,10 – 99,90) % (mol/mol)\nTlen (0,10 – 20,00) %(mol/mol)\nAzot (0,10 – 90,00) %(mol/mol)\nCO2 (0,10 – 45,00) %(mol/mol)\nCO (0,10 – 1,00) %(mol/mol)\nH2 (0,10 – 99,70) %(mol/mol)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną i termokonduktometryczną (GC-FID/TCD)","reference":"UOP 539-12","norm_bases":["UOP 539-12"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: gazy z procesów technologicznych: gazy opałowe, gazy wodorowe, gazy pooksydacyjne, gazy węglowodorowe Skład szczegółowy\nZakres:\nWęglowodory od C1 do C6\nZakres (0,10 – 99,90) % (mol/mol)\nTlen (0,10 – 20,00) %(mol/mol)\nAzot (0,10 – 90,00) %(mol/mol)\nCO2 (0,10 – 45,00) %(mol/mol)\nCO (0,10 – 1,00) %(mol/mol)\nH2 (0,10 – 99,70) %(mol/mol)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną i termokonduktometryczną (GC-FID/TCD) UOP 539-12 Paliwa gazowe: gazy z procesow technologicznych: gazy opalowe, gazy wodorowe, gazy pooksydacyjne, gazy weglowodorowe Sklad szczegolowy\nZakres:\nWeglowodory od C1 do C6\nZakres (0,10 – 99,90) % (mol/mol)\nTlen (0,10 – 20,00) %(mol/mol)\nAzot (0,10 – 90,00) %(mol/mol)\nCO2 (0,10 – 45,00) %(mol/mol)\nCO (0,10 – 1,00) %(mol/mol)\nH2 (0,10 – 99,70) %(mol/mol)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna i termokonduktometryczna (GC-FID/TCD) UOP 539-12","categories":["petro"],"row_index":286,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb664","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: gazy z procesów technologicznych: gazy pooksydacyjne, gazy węglowodorowe","methodology":"Zawartość węgla pierwiastkowego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość węgla pierwiastkowego (z obliczeń)","reference":"Metoda 103 wydanie 3 z dnia 07.01.2022","norm_bases":["Metoda 103 wydanie 3 z dnia 07.01.2022"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: gazy z procesów technologicznych: gazy pooksydacyjne, gazy węglowodorowe Zawartość węgla pierwiastkowego (z obliczeń) Metoda 103 wydanie 3 z dnia 07.01.2022 Paliwa gazowe: gazy z procesow technologicznych: gazy pooksydacyjne, gazy weglowodorowe Zawartosc wegla pierwiastkowego (z obliczen) Metoda 103 wydanie 3 z dnia 07.01.2022","categories":["petro"],"row_index":287,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb665","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: gazy z procesów technologicznych: gazy pooksydacyjne, gazy węglowodorowe","methodology":"Wartość opałowa (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wartość opałowa (z obliczeń)","reference":"PN-EN ISO 6976:2016-11","norm_bases":["PN-EN ISO 6976:2016-11"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: gazy z procesów technologicznych: gazy pooksydacyjne, gazy węglowodorowe Wartość opałowa (z obliczeń) PN-EN ISO 6976:2016-11 Paliwa gazowe: gazy z procesow technologicznych: gazy pooksydacyjne, gazy weglowodorowe Wartosc opalowa (z obliczen) PN-EN ISO 6976:2016-11","categories":["petro"],"row_index":288,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb666","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: gazy z procesów technologicznych: gazy pooksydacyjne, gazy węglowodorowe","methodology":"Gęstość (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Gęstość (z obliczeń)","reference":"PN-EN ISO 6976:2016-11","norm_bases":["PN-EN ISO 6976:2016-11"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: gazy z procesów technologicznych: gazy pooksydacyjne, gazy węglowodorowe Gęstość (z obliczeń) PN-EN ISO 6976:2016-11 Paliwa gazowe: gazy z procesow technologicznych: gazy pooksydacyjne, gazy weglowodorowe Gestosc (z obliczen) PN-EN ISO 6976:2016-11","categories":["petro"],"row_index":289,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb667","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: gaz ziemny","methodology":"Skład węglowodorowy","parameters":[{"name":"Zakres","range":"(0,0002 – 99,0000) %mol"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Skład węglowodorowy\nZakres (0,0002 – 99,0000) %mol\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 27941:2015-12","norm_bases":["PN-EN 27941:2015-12"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: gaz ziemny Skład węglowodorowy\nZakres (0,0002 – 99,0000) %mol\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 27941:2015-12 Paliwa gazowe: gaz ziemny Sklad weglowodorowy\nZakres (0,0002 – 99,0000) %mol\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 27941:2015-12","categories":["petro"],"row_index":290,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb668","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: gaz ziemny","methodology":"Zawartość azotu","parameters":[{"name":"Zakres","range":"(0,05 – 5,00) %mol"}],"technique":"Metoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD)","techniques":["Metoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD)"],"computed":[],"activity":"Zawartość azotu\nZakres (0,05 – 5,00) %mol\nMetoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD)","reference":"ASTM D 1946-24","norm_bases":["ASTM D 1946-24"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: gaz ziemny Zawartość azotu\nZakres (0,05 – 5,00) %mol\nMetoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD) ASTM D 1946-24 Paliwa gazowe: gaz ziemny Zawartosc azotu\nZakres (0,05 – 5,00) %mol\nMetoda chromatografii gazowej z detekcja termokonduktometryczna (GC-TCD) ASTM D 1946-24","categories":["petro"],"row_index":291,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb669","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: gaz ziemny","methodology":"Zawartość ditlenku węgla","parameters":[{"name":"Zakres","range":"(0,0010 – 1,0000) %mol"}],"technique":"Metoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD)","techniques":["Metoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD)"],"computed":[],"activity":"Zawartość ditlenku węgla\nZakres (0,0010 – 1,0000) %mol\nMetoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD)","reference":"Metoda 048 pkt 1.1 wyd. 4 z dnia 27.12.2023","norm_bases":["Metoda 048 pkt 1.1 wyd. 4 z dnia 27.12.2023"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: gaz ziemny Zawartość ditlenku węgla\nZakres (0,0010 – 1,0000) %mol\nMetoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD) Metoda 048 pkt 1.1 wyd. 4 z dnia 27.12.2023 Paliwa gazowe: gaz ziemny Zawartosc ditlenku wegla\nZakres (0,0010 – 1,0000) %mol\nMetoda chromatografii gazowej z detekcja termokonduktometryczna (GC-TCD) Metoda 048 pkt 1.1 wyd. 4 z dnia 27.12.2023","categories":["petro"],"row_index":292,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb66a","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: gaz ziemny","methodology":"Gęstość (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Gęstość (z obliczeń)","reference":"PN-EN ISO 6976:2016-11","norm_bases":["PN-EN ISO 6976:2016-11"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: gaz ziemny Gęstość (z obliczeń) PN-EN ISO 6976:2016-11 Paliwa gazowe: gaz ziemny Gestosc (z obliczen) PN-EN ISO 6976:2016-11","categories":["petro"],"row_index":293,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb66b","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: gaz ziemny","methodology":"Wartość opałowa (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wartość opałowa (z obliczeń)","reference":"PN-EN ISO 6976:2016-11","norm_bases":["PN-EN ISO 6976:2016-11"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: gaz ziemny Wartość opałowa (z obliczeń) PN-EN ISO 6976:2016-11 Paliwa gazowe: gaz ziemny Wartosc opalowa (z obliczen) PN-EN ISO 6976:2016-11","categories":["petro"],"row_index":294,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb66c","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: gaz opałowy","methodology":"Skład węglowodorowy","parameters":[{"name":"Zakres","range":"(0,01 – 99,00) %mol"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Skład węglowodorowy\nZakres (0,01 – 99,00) %mol\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 27941:2015-12","norm_bases":["PN-EN 27941:2015-12"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: gaz opałowy Skład węglowodorowy\nZakres (0,01 – 99,00) %mol\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 27941:2015-12 Paliwa gazowe: gaz opalowy Sklad weglowodorowy\nZakres (0,01 – 99,00) %mol\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 27941:2015-12","categories":["petro"],"row_index":295,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb66d","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: gaz opałowy","methodology":"Zawartość azotu","parameters":[{"name":"Zakres","range":"(0,05 – 10,00) %mol"}],"technique":"Metoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD)","techniques":["Metoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD)"],"computed":[],"activity":"Zawartość azotu\nZakres (0,05 – 10,00) %mol\nMetoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD)","reference":"ASTM D 1946-24","norm_bases":["ASTM D 1946-24"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: gaz opałowy Zawartość azotu\nZakres (0,05 – 10,00) %mol\nMetoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD) ASTM D 1946-24 Paliwa gazowe: gaz opalowy Zawartosc azotu\nZakres (0,05 – 10,00) %mol\nMetoda chromatografii gazowej z detekcja termokonduktometryczna (GC-TCD) ASTM D 1946-24","categories":["petro"],"row_index":296,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb66e","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: gaz opałowy","methodology":"Zawartość wodoru","parameters":[{"name":"Zakres","range":"(0,01 – 60,00) %mol"}],"technique":"Metoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD)","techniques":["Metoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD)"],"computed":[],"activity":"Zawartość wodoru\nZakres (0,01 – 60,00) %mol\nMetoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD)","reference":"ASTM D 1946-24","norm_bases":["ASTM D 1946-24"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: gaz opałowy Zawartość wodoru\nZakres (0,01 – 60,00) %mol\nMetoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD) ASTM D 1946-24 Paliwa gazowe: gaz opalowy Zawartosc wodoru\nZakres (0,01 – 60,00) %mol\nMetoda chromatografii gazowej z detekcja termokonduktometryczna (GC-TCD) ASTM D 1946-24","categories":["petro"],"row_index":297,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb66f","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: gaz opałowy","methodology":"Gęstość (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Gęstość (z obliczeń)","reference":"PN-EN ISO 6976:2016-11","norm_bases":["PN-EN ISO 6976:2016-11"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: gaz opałowy Gęstość (z obliczeń) PN-EN ISO 6976:2016-11 Paliwa gazowe: gaz opalowy Gestosc (z obliczen) PN-EN ISO 6976:2016-11","categories":["petro"],"row_index":298,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb670","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: gaz opałowy","methodology":"Wartość opałowa (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wartość opałowa (z obliczeń)","reference":"PN-EN ISO 6976:2016-11","norm_bases":["PN-EN ISO 6976:2016-11"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: gaz opałowy Wartość opałowa (z obliczeń) PN-EN ISO 6976:2016-11 Paliwa gazowe: gaz opalowy Wartosc opalowa (z obliczen) PN-EN ISO 6976:2016-11","categories":["petro"],"row_index":299,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb671","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość estrów metylowych kwasów tłuszczowych (FAME)","parameters":[{"name":"Suma estrów","range":"(90,0 – 100,0) %(m/m)"},{"name":"Zawartość estru metylowego kwasu linolenowego","range":"(1,0 – 15,0) % (m/m)"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość estrów metylowych kwasów tłuszczowych (FAME)\nZakres:\nSuma estrów (90,0 – 100,0) %(m/m)\nZawartość estru metylowego kwasu linolenowego (1,0 – 15,0) % (m/m)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 14103:2020-06","norm_bases":["PN-EN 14103:2020-06"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Zawartość estrów metylowych kwasów tłuszczowych (FAME)\nZakres:\nSuma estrów (90,0 – 100,0) %(m/m)\nZawartość estru metylowego kwasu linolenowego (1,0 – 15,0) % (m/m)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 14103:2020-06 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Zawartosc estrow metylowych kwasow tluszczowych (FAME)\nZakres:\nSuma estrow (90,0 – 100,0) %(m/m)\nZawartosc estru metylowego kwasu linolenowego (1,0 – 15,0) % (m/m)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 14103:2020-06","categories":["petro"],"row_index":300,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb672","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość sumy wielonienasyconych estrów metylowych kwasów tłuszczowych (≥4 wiązania podwójne) (PUFA)","parameters":[{"name":"Zakres","range":"(0,30 – 3,00) %(m/m)"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość sumy wielonienasyconych estrów metylowych kwasów tłuszczowych (≥4 wiązania podwójne) (PUFA)\nZakres (0,30 – 3,00) %(m/m)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 15779+A1:2013-12","norm_bases":["PN-EN 15779+A1:2013-12"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Zawartość sumy wielonienasyconych estrów metylowych kwasów tłuszczowych (≥4 wiązania podwójne) (PUFA)\nZakres (0,30 – 3,00) %(m/m)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 15779+A1:2013-12 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Zawartosc sumy wielonienasyconych estrow metylowych kwasow tluszczowych (≥4 wiazania podwojne) (PUFA)\nZakres (0,30 – 3,00) %(m/m)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 15779+A1:2013-12","categories":["petro"],"row_index":301,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb673","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość wolnego i ogólnego glicerolu oraz mono-, di- i triacylogliceroli","parameters":[{"name":"Monoacyloglicerole"},{"name":"Zakres","range":"(0,05 – 1,25) % (m/m)"},{"name":"Diacyloglicerole","range":"(0,05 – 0,50) %(m/m)"},{"name":"Triacyloglicerole","range":"(0,05 – 0,50) %(m/m)"},{"name":"Wolny glicerol","range":"(0,001 – 0,050) %(m/m)"},{"name":"Ogólny glicerol (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość wolnego i ogólnego glicerolu oraz mono-, di- i triacylogliceroli\nZakres:\nMonoacyloglicerole\nZakres (0,05 – 1,25) % (m/m)\nDiacyloglicerole (0,05 – 0,50) %(m/m)\nTriacyloglicerole (0,05 – 0,50) %(m/m)\nWolny glicerol (0,001 – 0,050) %(m/m)\nOgólny glicerol (z obliczeń)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 14105:2025-04","norm_bases":["PN-EN 14105:2025-04"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Zawartość wolnego i ogólnego glicerolu oraz mono-, di- i triacylogliceroli\nZakres:\nMonoacyloglicerole\nZakres (0,05 – 1,25) % (m/m)\nDiacyloglicerole (0,05 – 0,50) %(m/m)\nTriacyloglicerole (0,05 – 0,50) %(m/m)\nWolny glicerol (0,001 – 0,050) %(m/m)\nOgólny glicerol (z obliczeń)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 14105:2025-04 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Zawartosc wolnego i ogolnego glicerolu oraz mono-, di- i triacylogliceroli\nZakres:\nMonoacyloglicerole\nZakres (0,05 – 1,25) % (m/m)\nDiacyloglicerole (0,05 – 0,50) %(m/m)\nTriacyloglicerole (0,05 – 0,50) %(m/m)\nWolny glicerol (0,001 – 0,050) %(m/m)\nOgolny glicerol (z obliczen)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 14105:2025-04","categories":["petro"],"row_index":302,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb674","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: bioetanol","methodology":"Zawartość wyższych alkoholi, metanolu i innych zanieczyszczeń","parameters":[{"name":"metanol","range":"(0,010 – 3,000) %(m/m)"},{"name":"Wyższe alkohole","range":"(C3-C5)"},{"name":"Zakres","range":"(0,010 – 2,500) %(m/m)"},{"name":"etanol wraz z wyższymi alkoholami – powyżej 95,000 %(m/m) inne zanieczyszczenia","range":"(0,010 – 2,000) %(m/m)"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość wyższych alkoholi, metanolu i innych zanieczyszczeń\nZakres:\nmetanol (0,010 – 3,000) %(m/m)\nWyższe alkohole (C3-C5)\nZakres (0,010 – 2,500) %(m/m)\netanol wraz z wyższymi alkoholami – powyżej 95,000 %(m/m) inne zanieczyszczenia (0,010 – 2,000) %(m/m)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 15721:2013-10 Procedura A","norm_bases":["PN-EN 15721:2013-10 Procedura A"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: bioetanol Zawartość wyższych alkoholi, metanolu i innych zanieczyszczeń\nZakres:\nmetanol (0,010 – 3,000) %(m/m)\nWyższe alkohole (C3-C5)\nZakres (0,010 – 2,500) %(m/m)\netanol wraz z wyższymi alkoholami – powyżej 95,000 %(m/m) inne zanieczyszczenia (0,010 – 2,000) %(m/m)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 15721:2013-10 Procedura A Paliwa ciekle: biopaliwa ciekle: bioetanol Zawartosc wyzszych alkoholi, metanolu i innych zanieczyszczen\nZakres:\nmetanol (0,010 – 3,000) %(m/m)\nWyzsze alkohole (C3-C5)\nZakres (0,010 – 2,500) %(m/m)\netanol wraz z wyzszymi alkoholami – powyzej 95,000 %(m/m) inne zanieczyszczenia (0,010 – 2,000) %(m/m)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 15721:2013-10 Procedura A","categories":["petro"],"row_index":303,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb675","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie lotnych węglowodorów aromatycznych","parameters":[{"name":"benzen","range":"(3,0 – 14000) μg/l"},{"name":"toluen","range":"(3,0 – 14000) μg/l"},{"name":"etylobenzen","range":"(3,0 – 14000) μg/l"},{"name":"(m+p)-ksylen","range":"(3,0 – 27000) μg/l"},{"name":"o-ksylen","range":"(3,0 – 14000) μg/l"},{"name":"kumen","range":"(3,0 – 14000) μg/l"},{"name":"Suma ksylenów, suma BTEX (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID)","techniques":["Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID)"],"computed":[],"activity":"Stężenie lotnych węglowodorów aromatycznych\nZakres:\nbenzen (3,0 – 14000) μg/l\ntoluen (3,0 – 14000) μg/l\netylobenzen (3,0 – 14000) μg/l\n(m+p)-ksylen (3,0 – 27000) μg/l\no-ksylen (3,0 – 14000) μg/l\nkumen (3,0 – 14000) μg/l\nSuma ksylenów, suma BTEX (z obliczeń)\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID)","reference":"PN-ISO 11423-1:2002","norm_bases":["PN-ISO 11423-1:2002"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie lotnych węglowodorów aromatycznych\nZakres:\nbenzen (3,0 – 14000) μg/l\ntoluen (3,0 – 14000) μg/l\netylobenzen (3,0 – 14000) μg/l\n(m+p)-ksylen (3,0 – 27000) μg/l\no-ksylen (3,0 – 14000) μg/l\nkumen (3,0 – 14000) μg/l\nSuma ksylenów, suma BTEX (z obliczeń)\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID) PN-ISO 11423-1:2002 Woda, scieki Stezenie lotnych weglowodorow aromatycznych\nZakres:\nbenzen (3,0 – 14000) μg/l\ntoluen (3,0 – 14000) μg/l\netylobenzen (3,0 – 14000) μg/l\n(m+p)-ksylen (3,0 – 27000) μg/l\no-ksylen (3,0 – 14000) μg/l\nkumen (3,0 – 14000) μg/l\nSuma ksylenow, suma BTEX (z obliczen)\nMetoda chromatografii gazowej z analiza fazy nadpowierzchniowej i detekcja plomieniowo-jonizacyjna (HS-GC-FID) PN-ISO 11423-1:2002","categories":["water"],"row_index":304,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb676","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"Indeks oleju mineralnego","parameters":[{"name":"Zakres","range":"(0,10 – 100) mg/l"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Indeks oleju mineralnego\nZakres (0,10 – 100) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN ISO 9377-2:2003","norm_bases":["PN-EN ISO 9377-2:2003"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Indeks oleju mineralnego\nZakres (0,10 – 100) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN ISO 9377-2:2003 Scieki Indeks oleju mineralnego\nZakres (0,10 – 100) mg/l\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN ISO 9377-2:2003","categories":["water","petro"],"row_index":305,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb677","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy – próbki powietrza pobrane na filtry i rurki z sorbentem","methodology":"Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA)","parameters":[{"name":"antracen (0,005 – 0,500) μg w próbce benzo(a)antracen"},{"name":"Zakres","range":"(0,010 – 1,000) μg w próbce"},{"name":"chryzen (0,020 – 2,000) μg w próbce benzo(b)fluoranten (0,010 – 1,000) μg w próbce benzo(k)fluoranten (0,010 – 1,000) μg w próbce benzo(a)piren (0,020 – 2,000) μg w próbce dibenzo(ah)antracen (0,040 – 4,000) μg w próbce benzo(ghi)perylen (0,020 – 2,000) μg w próbce indeno","range":"(123cd)piren"},{"name":"(0,020 – 0,100) μg w próbce"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA)\nZakres:\nantracen (0,005 – 0,500) μg w próbce benzo(a)antracen\nZakres (0,010 – 1,000) μg w próbce\nchryzen (0,020 – 2,000) μg w próbce benzo(b)fluoranten (0,010 – 1,000) μg w próbce benzo(k)fluoranten (0,010 – 1,000) μg w próbce benzo(a)piren (0,020 – 2,000) μg w próbce dibenzo(ah)antracen (0,040 – 4,000) μg w próbce benzo(ghi)perylen (0,020 – 2,000) μg w próbce indeno (123cd)piren\n(0,020 – 0,100) μg w próbce\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"PN-Z-04240-5:2006","norm_bases":["PN-Z-04240-5:2006"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – próbki powietrza pobrane na filtry i rurki z sorbentem Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA)\nZakres:\nantracen (0,005 – 0,500) μg w próbce benzo(a)antracen\nZakres (0,010 – 1,000) μg w próbce\nchryzen (0,020 – 2,000) μg w próbce benzo(b)fluoranten (0,010 – 1,000) μg w próbce benzo(k)fluoranten (0,010 – 1,000) μg w próbce benzo(a)piren (0,020 – 2,000) μg w próbce dibenzo(ah)antracen (0,040 – 4,000) μg w próbce benzo(ghi)perylen (0,020 – 2,000) μg w próbce indeno (123cd)piren\n(0,020 – 0,100) μg w próbce\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) PN-Z-04240-5:2006 Srodowisko pracy – probki powietrza pobrane na filtry i rurki z sorbentem Zawartosc wielopierscieniowych weglowodorow aromatycznych (WWA)\nZakres:\nantracen (0,005 – 0,500) μg w probce benzo(a)antracen\nZakres (0,010 – 1,000) μg w probce\nchryzen (0,020 – 2,000) μg w probce benzo(b)fluoranten (0,010 – 1,000) μg w probce benzo(k)fluoranten (0,010 – 1,000) μg w probce benzo(a)piren (0,020 – 2,000) μg w probce dibenzo(ah)antracen (0,040 – 4,000) μg w probce benzo(ghi)perylen (0,020 – 2,000) μg w probce indeno (123cd)piren\n(0,020 – 0,100) μg w probce\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) PN-Z-04240-5:2006","categories":["environment"],"row_index":306,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb678","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, benzyna, olej opałowy lekki, olej opałowy ciężki, paliwo do turbinowych silników lotniczych, biopaliwo ciekłe: estry metylowe kwasów tłuszczowych (FAME), bioetanol","methodology":"Pobieranie próbek ze zbiorników do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek ze zbiorników do badań chemicznych i fizycznych","reference":"PN-EN ISO 3170:2025-12 z wyłączeniem 8.3.1.5, 8.3.1.8, 8.3.2, 8.7,8.8, 10.6, 10.7","norm_bases":["PN-EN ISO 3170:2025-12 z wyłączeniem 8.3.1.5, 8.3.1.8, 8.3.2, 8.7,8.8, 10.6, 10.7"],"lab_section":"Zespół Logistyki Płock LL/P","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, benzyna, olej opałowy lekki, olej opałowy ciężki, paliwo do turbinowych silników lotniczych, biopaliwo ciekłe: estry metylowe kwasów tłuszczowych (FAME), bioetanol Pobieranie próbek ze zbiorników do badań chemicznych i fizycznych PN-EN ISO 3170:2025-12 z wyłączeniem 8.3.1.5, 8.3.1.8, 8.3.2, 8.7,8.8, 10.6, 10.7 Paliwa ciekle: olej napedowy, benzyna, olej opalowy lekki, olej opalowy ciezki, paliwo do turbinowych silnikow lotniczych, biopaliwo ciekle: estry metylowe kwasow tluszczowych (FAME), bioetanol Pobieranie probek ze zbiornikow do badan chemicznych i fizycznych PN-EN ISO 3170:2025-12 z wylaczeniem 8.3.1.5, 8.3.1.8, 8.3.2, 8.7,8.8, 10.6, 10.7","categories":["petro"],"row_index":307,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb679","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, benzyna","methodology":"Pobieranie próbek z dystrybutora do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek z dystrybutora do badań chemicznych i fizycznych","reference":"PN-EN 14275:2013-06","norm_bases":["PN-EN 14275:2013-06"],"lab_section":"Zespół Logistyki Płock LL/P","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, benzyna Pobieranie próbek z dystrybutora do badań chemicznych i fizycznych PN-EN 14275:2013-06 Paliwa ciekle: olej napedowy, benzyna Pobieranie probek z dystrybutora do badan chemicznych i fizycznych PN-EN 14275:2013-06","categories":["petro"],"row_index":308,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb67a","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-EN ISO 4257:2004 ZN/MG/CN-18:2007","norm_bases":["PN-EN ISO 4257:2004 ZN/MG/CN-18:2007"],"lab_section":"Zespół Logistyki Płock LL/P","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Pobieranie próbek do badań chemicznych i fizycznych PN-EN ISO 4257:2004 ZN/MG/CN-18:2007 Paliwa gazowe: skroplone gazy weglowodorowe, LPG Pobieranie probek do badan chemicznych i fizycznych PN-EN ISO 4257:2004 ZN/MG/CN-18:2007","categories":["petro"],"row_index":309,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb67b","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[{"name":"Temperatura pobranej próbki ścieków"},{"name":"Zakres","range":"(2,0 – 50,0) °C"}],"technique":"Metoda manualna","techniques":["Metoda manualna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura pobranej próbki ścieków\nZakres (2,0 – 50,0) °C\nMetoda manualna","reference":"PN-ISO 5667-10:2021-11 Metoda nr 111 Wydanie 5 z dnia 01.07.2020","norm_bases":["PN-ISO 5667-10:2021-11 Metoda nr 111 Wydanie 5 z dnia 01.07.2020"],"lab_section":"Zespół Logistyki Płock LL/P","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura pobranej próbki ścieków\nZakres (2,0 – 50,0) °C\nMetoda manualna PN-ISO 5667-10:2021-11 Metoda nr 111 Wydanie 5 z dnia 01.07.2020 Scieki Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nTemperatura pobranej probki sciekow\nZakres (2,0 – 50,0) °C\nMetoda manualna PN-ISO 5667-10:2021-11 Metoda nr 111 Wydanie 5 z dnia 01.07.2020","categories":["water"],"row_index":310,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb67c","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Zespół Logistyki Płock LL/P","lab_address":null,"regulatory_area":"Badania wykonywane poza siedzibą laboratorium","flexible":false,"search_text":"Ścieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Scieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":311,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb67d","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: wodór (automotive)","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[{"name":"ze zbiorników"},{"name":"ze stacji tankowania"},{"name":"z rurociągów na instalacji"}],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nze zbiorników\nze stacji tankowania\nz rurociągów na instalacji","reference":"ASTM D 7606-24a | ISO 21087:2019-06 p. 8 | ISO 19880-1:2020-03 załącznik K p. K1, K2, K3 | ISO 19880-09:2024 z wyłączeniem załącznika A, C, D, E, F","norm_bases":["ASTM D 7606-24a","ISO 21087:2019-06 p. 8","ISO 19880-1:2020-03 załącznik K p. K1, K2, K3","ISO 19880-09:2024 z wyłączeniem załącznika A, C, D, E, F"],"lab_section":"Zespół Logistyki Płock LL/P","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: wodór (automotive) Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nze zbiorników\nze stacji tankowania\nz rurociągów na instalacji ASTM D 7606-24a | ISO 21087:2019-06 p. 8 | ISO 19880-1:2020-03 załącznik K p. K1, K2, K3 | ISO 19880-09:2024 z wyłączeniem załącznika A, C, D, E, F Paliwa gazowe: wodor (automotive) Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nze zbiornikow\nze stacji tankowania\nz rurociagow na instalacji ASTM D 7606-24a | ISO 21087:2019-06 p. 8 | ISO 19880-1:2020-03 zalacznik K p. K1, K2, K3 | ISO 19880-09:2024 z wylaczeniem zalacznika A, C, D, E, F","categories":["petro","automotive"],"row_index":312,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb67e","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: wodór (automotive)","methodology":"Pobieranie próbek do zawartości cząstek stałych","parameters":[{"name":"ze zbiorników"},{"name":"ze stacji tankowania"},{"name":"z rurociągów"}],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do zawartości cząstek stałych\nZakres:\nze zbiorników\nze stacji tankowania\nz rurociągów","reference":"ASTM D 7650-21 z wyłączeniem 7.9 | ISO 21087:2019-06 p. 8 | ISO 19880-1:2020-03 załącznik K p. K1, K2, K7 z wyłączeniem p. K.7.1 | ISO 19880-9:2024-07 z wyłączeniem załącznika A, B, C, E, F","norm_bases":["ASTM D 7650-21 z wyłączeniem 7.9","ISO 21087:2019-06 p. 8","ISO 19880-1:2020-03 załącznik K p. K1, K2, K7 z wyłączeniem p. K.7.1","ISO 19880-9:2024-07 z wyłączeniem załącznika A, B, C, E, F"],"lab_section":"Zespół Logistyki Płock LL/P","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: wodór (automotive) Pobieranie próbek do zawartości cząstek stałych\nZakres:\nze zbiorników\nze stacji tankowania\nz rurociągów ASTM D 7650-21 z wyłączeniem 7.9 | ISO 21087:2019-06 p. 8 | ISO 19880-1:2020-03 załącznik K p. K1, K2, K7 z wyłączeniem p. K.7.1 | ISO 19880-9:2024-07 z wyłączeniem załącznika A, B, C, E, F Paliwa gazowe: wodor (automotive) Pobieranie probek do zawartosci czastek stalych\nZakres:\nze zbiornikow\nze stacji tankowania\nz rurociagow ASTM D 7650-21 z wylaczeniem 7.9 | ISO 21087:2019-06 p. 8 | ISO 19880-1:2020-03 zalacznik K p. K1, K2, K7 z wylaczeniem p. K.7.1 | ISO 19880-9:2024-07 z wylaczeniem zalacznika A, B, C, E, F","categories":["petro","automotive"],"row_index":313,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb67f","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[{"name":"Temperatura pobranej próbki Zakres:","range":"(2,0 – 50,0) °C"}],"technique":"Metoda manualna","techniques":["Metoda manualna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nTemperatura pobranej próbki Zakres: (2,0 – 50,0) °C\nMetoda manualna","reference":"PN-ISO 5667-10:2021-11 Metoda nr 111 Wydanie 5 z dnia 01.07.2020","norm_bases":["PN-ISO 5667-10:2021-11 Metoda nr 111 Wydanie 5 z dnia 01.07.2020"],"lab_section":"Zespół Logistyki Włocławek LL/W","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nTemperatura pobranej próbki Zakres: (2,0 – 50,0) °C\nMetoda manualna PN-ISO 5667-10:2021-11 Metoda nr 111 Wydanie 5 z dnia 01.07.2020 Scieki Pobieranie probek do badan chemicznych i fizycznych\nTemperatura pobranej probki Zakres: (2,0 – 50,0) °C\nMetoda manualna PN-ISO 5667-10:2021-11 Metoda nr 111 Wydanie 5 z dnia 01.07.2020","categories":["water"],"row_index":314,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb680","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":"Metoda automatyczna","techniques":["Metoda automatyczna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda automatyczna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":"Zespół Logistyki Włocławek LL/W","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nMetoda automatyczna PN-ISO 5667-10:2021-11 Scieki Pobieranie probek do badan chemicznych i fizycznych\nMetoda automatyczna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":315,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb681","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Zespół Logistyki Włocławek LL/W","lab_address":null,"regulatory_area":"Badania wykonywane poza siedzibą laboratorium","flexible":false,"search_text":"Ścieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Scieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":316,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb682","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Wody powierzchniowe","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki","parameters":[{"name":"Zakres","range":"(2,0 – 50,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki\nZakres (2,0 – 50,0) °C","reference":"PN-EN ISO 5667-6:2016-12 z wyłączeniem 7.6, 9.4 Metoda nr 111 Wydanie 5 z dnia 01.07.2020","norm_bases":["PN-EN ISO 5667-6:2016-12 z wyłączeniem 7.6, 9.4 Metoda nr 111 Wydanie 5 z dnia 01.07.2020"],"lab_section":"Zespół Logistyki Włocławek LL/W","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wody powierzchniowe Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki\nZakres (2,0 – 50,0) °C PN-EN ISO 5667-6:2016-12 z wyłączeniem 7.6, 9.4 Metoda nr 111 Wydanie 5 z dnia 01.07.2020 Wody powierzchniowe Pobieranie probek do badan chemicznych i fizycznych Temperatura pobranej probki\nZakres (2,0 – 50,0) °C PN-EN ISO 5667-6:2016-12 z wylaczeniem 7.6, 9.4 Metoda nr 111 Wydanie 5 z dnia 01.07.2020","categories":["water"],"row_index":317,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb683","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Wody powierzchniowe","methodology":"pH","parameters":[{"name":"Zakres","range":"(2,0 – 12,0)"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres (2,0 – 12,0)\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Zespół Logistyki Włocławek LL/W","lab_address":null,"regulatory_area":"Badania wykonywane poza siedzibą laboratorium","flexible":false,"search_text":"Wody powierzchniowe pH\nZakres (2,0 – 12,0)\nMetoda potencjometryczna PN-EN ISO 10523:2012 Wody powierzchniowe pH\nZakres (2,0 – 12,0)\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":318,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb684","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Wody powierzchniowe","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(0,100 – 20,00) mS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (0,100 – 20,00) mS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Zespół Logistyki Włocławek LL/W","lab_address":null,"regulatory_area":"Badania wykonywane poza siedzibą laboratorium","flexible":false,"search_text":"Wody powierzchniowe Przewodność elektryczna właściwa\nZakres (0,100 – 20,00) mS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Wody powierzchniowe Przewodnosc elektryczna wlasciwa\nZakres (0,100 – 20,00) mS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":319,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb685","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Wody podziemne","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki","parameters":[{"name":"Zakres","range":"(2,0 – 50,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki\nZakres (2,0 – 50,0) °C","reference":"PN-ISO 5667-11:2017-10 z wyłączeniem pkt 4.2.2, 4.2.4, 4.3, 6.2, 6.3 Metoda nr 111 Wydanie 5 z dnia 01.07.2020","norm_bases":["PN-ISO 5667-11:2017-10 z wyłączeniem pkt 4.2.2, 4.2.4, 4.3, 6.2, 6.3 Metoda nr 111 Wydanie 5 z dnia 01.07.2020"],"lab_section":"Zespół Logistyki Włocławek LL/W","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wody podziemne Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki\nZakres (2,0 – 50,0) °C PN-ISO 5667-11:2017-10 z wyłączeniem pkt 4.2.2, 4.2.4, 4.3, 6.2, 6.3 Metoda nr 111 Wydanie 5 z dnia 01.07.2020 Wody podziemne Pobieranie probek do badan chemicznych i fizycznych Temperatura pobranej probki\nZakres (2,0 – 50,0) °C PN-ISO 5667-11:2017-10 z wylaczeniem pkt 4.2.2, 4.2.4, 4.3, 6.2, 6.3 Metoda nr 111 Wydanie 5 z dnia 01.07.2020","categories":["water"],"row_index":320,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb686","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Wody podziemne","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Zespół Logistyki Włocławek LL/W","lab_address":null,"regulatory_area":"Badania wykonywane poza siedzibą laboratorium","flexible":false,"search_text":"Wody podziemne pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Wody podziemne pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":321,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb687","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Wody podziemne","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(0,100 – 20,00) mS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (0,100 – 20,00) mS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Zespół Logistyki Włocławek LL/W","lab_address":null,"regulatory_area":"Badania wykonywane poza siedzibą laboratorium","flexible":false,"search_text":"Wody podziemne Przewodność elektryczna właściwa\nZakres (0,100 – 20,00) mS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Wody podziemne Przewodnosc elektryczna wlasciwa\nZakres (0,100 – 20,00) mS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":322,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb688","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Wody, w tym wody do spożycia","methodology":"Pobieranie próbek do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007 z wył. punktów 4.4.2, 4.4.3, 4.4.4, 4.4.5, 4.4.6","norm_bases":["PN-EN ISO 19458:2007 z wył. punktów 4.4.2, 4.4.3, 4.4.4, 4.4.5, 4.4.6"],"lab_section":"Zespół Logistyki Włocławek LL/W","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wody, w tym wody do spożycia Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 z wył. punktów 4.4.2, 4.4.3, 4.4.4, 4.4.5, 4.4.6 Wody, w tym wody do spozycia Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007 z wyl. punktow 4.4.2, 4.4.3, 4.4.4, 4.4.5, 4.4.6","categories":["water","microbiology"],"row_index":323,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb689","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda do spożycia","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki","parameters":[{"name":"Zakres","range":"(2,0 – 30,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki\nZakres (2,0 – 30,0) °C","reference":"PN-ISO 5667-5:2017-10 Metoda nr 111 Wydanie 5 z dnia 01.07.2020","norm_bases":["PN-ISO 5667-5:2017-10 Metoda nr 111 Wydanie 5 z dnia 01.07.2020"],"lab_section":"Zespół Logistyki Włocławek LL/W","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki\nZakres (2,0 – 30,0) °C PN-ISO 5667-5:2017-10 Metoda nr 111 Wydanie 5 z dnia 01.07.2020 Woda do spozycia Pobieranie probek do badan chemicznych i fizycznych Temperatura pobranej probki\nZakres (2,0 – 30,0) °C PN-ISO 5667-5:2017-10 Metoda nr 111 Wydanie 5 z dnia 01.07.2020","categories":["water"],"row_index":324,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb68a","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie chloru wolnego Zakres: chlor wolny (0,20 – 1,6) mg/l","parameters":[],"technique":"Metoda kolorymetryczna","techniques":["Metoda kolorymetryczna"],"computed":[],"activity":"Stężenie chloru wolnego Zakres: chlor wolny (0,20 – 1,6) mg/l\nMetoda kolorymetryczna","reference":"Metoda nr 195 Wydanie 1 z dnia 26.09.2019 Test HACH Nr 8021 (chlor wolny)","norm_bases":["Metoda nr 195 Wydanie 1 z dnia 26.09.2019 Test HACH Nr 8021 (chlor wolny)"],"lab_section":"Zespół Logistyki Włocławek LL/W","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie chloru wolnego Zakres: chlor wolny (0,20 – 1,6) mg/l\nMetoda kolorymetryczna Metoda nr 195 Wydanie 1 z dnia 26.09.2019 Test HACH Nr 8021 (chlor wolny) Woda Stezenie chloru wolnego Zakres: chlor wolny (0,20 – 1,6) mg/l\nMetoda kolorymetryczna Metoda nr 195 Wydanie 1 z dnia 26.09.2019 Test HACH Nr 8021 (chlor wolny)","categories":["water"],"row_index":325,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb68b","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwo gazowe: wodór (automotive)","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[{"name":"ze zbiorników"},{"name":"ze stacji tankowania"},{"name":"z rurociągów na instalacji"}],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nze zbiorników\nze stacji tankowania\nz rurociągów na instalacji","reference":"ASTM D 7606-24a | ISO 21087:2019-06 p. 8 | ISO 19880-1:2020-03 załącznik K p. K1, K2, K3 | ISO 19880-09:2024 z wyłączeniem załącznika A, C, D, E, F","norm_bases":["ASTM D 7606-24a","ISO 21087:2019-06 p. 8","ISO 19880-1:2020-03 załącznik K p. K1, K2, K3","ISO 19880-09:2024 z wyłączeniem załącznika A, C, D, E, F"],"lab_section":"Zespół Logistyki Włocławek LL/W","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwo gazowe: wodór (automotive) Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nze zbiorników\nze stacji tankowania\nz rurociągów na instalacji ASTM D 7606-24a | ISO 21087:2019-06 p. 8 | ISO 19880-1:2020-03 załącznik K p. K1, K2, K3 | ISO 19880-09:2024 z wyłączeniem załącznika A, C, D, E, F Paliwo gazowe: wodor (automotive) Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nze zbiornikow\nze stacji tankowania\nz rurociagow na instalacji ASTM D 7606-24a | ISO 21087:2019-06 p. 8 | ISO 19880-1:2020-03 zalacznik K p. K1, K2, K3 | ISO 19880-09:2024 z wylaczeniem zalacznika A, C, D, E, F","categories":["petro","automotive"],"row_index":326,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb68c","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwo gazowe: wodór (automotive)","methodology":"Pobieranie próbek do zawartości cząstek stałych","parameters":[{"name":"ze zbiorników"},{"name":"ze stacji tankowania"},{"name":"z rurociągów"}],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do zawartości cząstek stałych\nZakres:\nze zbiorników\nze stacji tankowania\nz rurociągów","reference":"ASTM D 7650-21 z wyłączeniem 7.9 | ISO 21087:2019-06 p. 8 | ISO 19880-1:2020-03 załącznik K p. K1, K2, K7 z wyłączeniem p. K.7.1 | ISO 19880-9:2024-07 z wyłączeniem załącznika A, B, C, E, F","norm_bases":["ASTM D 7650-21 z wyłączeniem 7.9","ISO 21087:2019-06 p. 8","ISO 19880-1:2020-03 załącznik K p. K1, K2, K7 z wyłączeniem p. K.7.1","ISO 19880-9:2024-07 z wyłączeniem załącznika A, B, C, E, F"],"lab_section":"Zespół Logistyki Włocławek LL/W","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwo gazowe: wodór (automotive) Pobieranie próbek do zawartości cząstek stałych\nZakres:\nze zbiorników\nze stacji tankowania\nz rurociągów ASTM D 7650-21 z wyłączeniem 7.9 | ISO 21087:2019-06 p. 8 | ISO 19880-1:2020-03 załącznik K p. K1, K2, K7 z wyłączeniem p. K.7.1 | ISO 19880-9:2024-07 z wyłączeniem załącznika A, B, C, E, F Paliwo gazowe: wodor (automotive) Pobieranie probek do zawartosci czastek stalych\nZakres:\nze zbiornikow\nze stacji tankowania\nz rurociagow ASTM D 7650-21 z wylaczeniem 7.9 | ISO 21087:2019-06 p. 8 | ISO 19880-1:2020-03 zalacznik K p. K1, K2, K7 z wylaczeniem p. K.7.1 | ISO 19880-9:2024-07 z wylaczeniem zalacznika A, B, C, E, F","categories":["petro","automotive"],"row_index":327,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb68d","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Wyroby chemiczne: kwas tereftalowy (PTA)","methodology":"Transparentność alkaliczna","parameters":[{"name":"Zakres","range":"(87,4 – 99,6)%"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Transparentność alkaliczna\nZakres (87,4 – 99,6)%\nMetoda spektrofotometryczna","reference":"Metoda nr 117 wydanie 4 z dnia 05.12.2025","norm_bases":["Metoda nr 117 wydanie 4 z dnia 05.12.2025"],"lab_section":"Pracownia PTA TT5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby chemiczne: kwas tereftalowy (PTA) Transparentność alkaliczna\nZakres (87,4 – 99,6)%\nMetoda spektrofotometryczna Metoda nr 117 wydanie 4 z dnia 05.12.2025 Wyroby chemiczne: kwas tereftalowy (PTA) Transparentnosc alkaliczna\nZakres (87,4 – 99,6)%\nMetoda spektrofotometryczna Metoda nr 117 wydanie 4 z dnia 05.12.2025","categories":["other"],"row_index":328,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb68e","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Wyroby chemiczne: kwas tereftalowy (PTA)","methodology":"Zawartość pierwiastków","parameters":[{"name":"Ca","range":"(0,01 – 1,00) mg/kg"},{"name":"Co","range":"(0,01 – 1,00) mg/kg"},{"name":"Cr","range":"(0,01 – 1,00) mg/kg"},{"name":"Fe","range":"(0,01 – 1,00) mg/kg"},{"name":"Na","range":"(0,01 – 1,00) mg/kg"},{"name":"Ni","range":"(0,01 – 1,00) mg/kg"},{"name":"Mn","range":"(0,01 – 1,00) mg/kg"},{"name":"Mo","range":"(0,01 – 1,00) mg/kg"},{"name":"Sumaryczna zawartość pierwiastków (z obliczeń)"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość pierwiastków\nZakres:\nCa (0,01 – 1,00) mg/kg\nCo (0,01 – 1,00) mg/kg\nCr (0,01 – 1,00) mg/kg\nFe (0,01 – 1,00) mg/kg\nNa (0,01 – 1,00) mg/kg\nNi (0,01 – 1,00) mg/kg\nMn (0,01 – 1,00) mg/kg\nMo (0,01 – 1,00) mg/kg\nSumaryczna zawartość pierwiastków (z obliczeń)\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"Metoda 118 wyd. 7 z dnia 07.04.2026","norm_bases":["Metoda 118 wyd. 7 z dnia 07.04.2026"],"lab_section":"Pracownia PTA TT5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby chemiczne: kwas tereftalowy (PTA) Zawartość pierwiastków\nZakres:\nCa (0,01 – 1,00) mg/kg\nCo (0,01 – 1,00) mg/kg\nCr (0,01 – 1,00) mg/kg\nFe (0,01 – 1,00) mg/kg\nNa (0,01 – 1,00) mg/kg\nNi (0,01 – 1,00) mg/kg\nMn (0,01 – 1,00) mg/kg\nMo (0,01 – 1,00) mg/kg\nSumaryczna zawartość pierwiastków (z obliczeń)\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) Metoda 118 wyd. 7 z dnia 07.04.2026 Wyroby chemiczne: kwas tereftalowy (PTA) Zawartosc pierwiastkow\nZakres:\nCa (0,01 – 1,00) mg/kg\nCo (0,01 – 1,00) mg/kg\nCr (0,01 – 1,00) mg/kg\nFe (0,01 – 1,00) mg/kg\nNa (0,01 – 1,00) mg/kg\nNi (0,01 – 1,00) mg/kg\nMn (0,01 – 1,00) mg/kg\nMo (0,01 – 1,00) mg/kg\nSumaryczna zawartosc pierwiastkow (z obliczen)\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) Metoda 118 wyd. 7 z dnia 07.04.2026","categories":["other"],"row_index":329,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb68f","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Wyroby chemiczne: kwas tereftalowy (PTA)","methodology":"Wygląd","parameters":[],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Wygląd\nMetoda wizualna","reference":"Metoda nr 122 wydanie 4 z dnia 05.12.2025","norm_bases":["Metoda nr 122 wydanie 4 z dnia 05.12.2025"],"lab_section":"Pracownia PTA TT5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby chemiczne: kwas tereftalowy (PTA) Wygląd\nMetoda wizualna Metoda nr 122 wydanie 4 z dnia 05.12.2025 Wyroby chemiczne: kwas tereftalowy (PTA) Wyglad\nMetoda wizualna Metoda nr 122 wydanie 4 z dnia 05.12.2025","categories":["other"],"row_index":330,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb690","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Wyroby chemiczne: kwas tereftalowy (PTA)","methodology":"Barwa w skali Pt-Co","parameters":[{"name":"Zakres","range":"5 – 15"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Barwa w skali Pt-Co\nZakres 5 – 15\nMetoda wizualna","reference":"Metoda nr 126 wydanie 4 z dnia 05.12.2025","norm_bases":["Metoda nr 126 wydanie 4 z dnia 05.12.2025"],"lab_section":"Pracownia PTA TT5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby chemiczne: kwas tereftalowy (PTA) Barwa w skali Pt-Co\nZakres 5 – 15\nMetoda wizualna Metoda nr 126 wydanie 4 z dnia 05.12.2025 Wyroby chemiczne: kwas tereftalowy (PTA) Barwa w skali Pt-Co\nZakres 5 – 15\nMetoda wizualna Metoda nr 126 wydanie 4 z dnia 05.12.2025","categories":["other"],"row_index":331,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb691","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Wyroby chemiczne: kwas tereftalowy (PTA)","methodology":"Zawartość wody","parameters":[{"name":"Zakres","range":"(0,10 – 1,00) %(m/m)"}],"technique":"Metoda miareczkowania potencjometrycznego","techniques":["Metoda miareczkowania potencjometrycznego"],"computed":[],"activity":"Zawartość wody\nZakres (0,10 – 1,00) %(m/m)\nMetoda miareczkowania potencjometrycznego","reference":"Metoda nr 127 wydanie 4 z dnia 05.12.2025","norm_bases":["Metoda nr 127 wydanie 4 z dnia 05.12.2025"],"lab_section":"Pracownia PTA TT5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby chemiczne: kwas tereftalowy (PTA) Zawartość wody\nZakres (0,10 – 1,00) %(m/m)\nMetoda miareczkowania potencjometrycznego Metoda nr 127 wydanie 4 z dnia 05.12.2025 Wyroby chemiczne: kwas tereftalowy (PTA) Zawartosc wody\nZakres (0,10 – 1,00) %(m/m)\nMetoda miareczkowania potencjometrycznego Metoda nr 127 wydanie 4 z dnia 05.12.2025","categories":["water"],"row_index":332,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb692","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Wyroby chemiczne: kwas tereftalowy (PTA)","methodology":"Barwa b","parameters":[{"name":"Zakres","range":"(0,1 – 2,0)"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Barwa b\nZakres (0,1 – 2,0)\nMetoda spektrofotometryczna","reference":"Metoda nr 128 wydanie 4 z dnia 05.12.2025","norm_bases":["Metoda nr 128 wydanie 4 z dnia 05.12.2025"],"lab_section":"Pracownia PTA TT5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby chemiczne: kwas tereftalowy (PTA) Barwa b\nZakres (0,1 – 2,0)\nMetoda spektrofotometryczna Metoda nr 128 wydanie 4 z dnia 05.12.2025 Wyroby chemiczne: kwas tereftalowy (PTA) Barwa b\nZakres (0,1 – 2,0)\nMetoda spektrofotometryczna Metoda nr 128 wydanie 4 z dnia 05.12.2025","categories":["other"],"row_index":333,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb693","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Wyroby chemiczne: kwas tereftalowy (PTA)","methodology":"Delta Y","parameters":[{"name":"Zakres","range":"(1,0 – 10,0)"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Delta Y\nZakres (1,0 – 10,0)\nMetoda spektrofotometryczna","reference":"Metoda nr 129 wydanie 4 z dnia 05.12.2025","norm_bases":["Metoda nr 129 wydanie 4 z dnia 05.12.2025"],"lab_section":"Pracownia PTA TT5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby chemiczne: kwas tereftalowy (PTA) Delta Y\nZakres (1,0 – 10,0)\nMetoda spektrofotometryczna Metoda nr 129 wydanie 4 z dnia 05.12.2025 Wyroby chemiczne: kwas tereftalowy (PTA) Delta Y\nZakres (1,0 – 10,0)\nMetoda spektrofotometryczna Metoda nr 129 wydanie 4 z dnia 05.12.2025","categories":["other"],"row_index":334,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb694","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Wyroby chemiczne: kwas tereftalowy (PTA)","methodology":"Liczba kwasowa","parameters":[{"name":"Zakres","range":"(673 – 677) mg KOH/g"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Liczba kwasowa\nZakres (673 – 677) mg KOH/g\nMetoda miareczkowa","reference":"Metoda nr 130 wydanie 4 z dnia 05.12.2025","norm_bases":["Metoda nr 130 wydanie 4 z dnia 05.12.2025"],"lab_section":"Pracownia PTA TT5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby chemiczne: kwas tereftalowy (PTA) Liczba kwasowa\nZakres (673 – 677) mg KOH/g\nMetoda miareczkowa Metoda nr 130 wydanie 4 z dnia 05.12.2025 Wyroby chemiczne: kwas tereftalowy (PTA) Liczba kwasowa\nZakres (673 – 677) mg KOH/g\nMetoda miareczkowa Metoda nr 130 wydanie 4 z dnia 05.12.2025","categories":["other"],"row_index":335,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb695","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Wyroby chemiczne: kwas tereftalowy (PTA)","methodology":"Pozostałość po spopieleniu","parameters":[{"name":"Zakres","range":"(1 – 5) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Pozostałość po spopieleniu\nZakres (1 – 5) mg/kg\nMetoda wagowa","reference":"Metoda nr 132 wydanie 3 z dnia 12.01.2023","norm_bases":["Metoda nr 132 wydanie 3 z dnia 12.01.2023"],"lab_section":"Pracownia PTA TT5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby chemiczne: kwas tereftalowy (PTA) Pozostałość po spopieleniu\nZakres (1 – 5) mg/kg\nMetoda wagowa Metoda nr 132 wydanie 3 z dnia 12.01.2023 Wyroby chemiczne: kwas tereftalowy (PTA) Pozostalosc po spopieleniu\nZakres (1 – 5) mg/kg\nMetoda wagowa Metoda nr 132 wydanie 3 z dnia 12.01.2023","categories":["other"],"row_index":336,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb696","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Wyroby chemiczne: kwas tereftalowy (PTA)","methodology":"Wartość Dp50","parameters":[{"name":"Zakres","range":"(70 – 130) μm"}],"technique":"Metoda sitowa (i z obliczeń)","techniques":["Metoda sitowa (i z obliczeń)"],"computed":[],"activity":"Wartość Dp50\nZakres (70 – 130) μm\nMetoda sitowa (i z obliczeń)","reference":"Metoda nr 133 wydanie 4 z dnia 05.12.2025","norm_bases":["Metoda nr 133 wydanie 4 z dnia 05.12.2025"],"lab_section":"Pracownia PTA TT5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby chemiczne: kwas tereftalowy (PTA) Wartość Dp50\nZakres (70 – 130) μm\nMetoda sitowa (i z obliczeń) Metoda nr 133 wydanie 4 z dnia 05.12.2025 Wyroby chemiczne: kwas tereftalowy (PTA) Wartosc Dp50\nZakres (70 – 130) μm\nMetoda sitowa (i z obliczen) Metoda nr 133 wydanie 4 z dnia 05.12.2025","categories":["other"],"row_index":337,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb697","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Zawartość ogólnego węgla organicznego","parameters":[{"name":"Zakres","range":"(0,3 – 24000) mg/l"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość ogólnego węgla organicznego\nZakres (0,3 – 24000) mg/l\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN 1484:1999","norm_bases":["PN-EN 1484:1999"],"lab_section":"Pracownia PTA TT5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Zawartość ogólnego węgla organicznego\nZakres (0,3 – 24000) mg/l\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN 1484:1999 Woda, scieki Zawartosc ogolnego wegla organicznego\nZakres (0,3 – 24000) mg/l\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN 1484:1999","categories":["water"],"row_index":338,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb698","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki, Biopaliwa ciekłe: estry metylowe kwasów tłuszczowych, bioetanol","methodology":"Pobieranie próbek ze zbiorników do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek ze zbiorników do badań chemicznych i fizycznych","reference":"PN-EN ISO 3170:2025-12 z wyłączeniem 8.3.1.3 - 8.3.1.6, 8.3.1.8, 8.3.2, 8.7, 8.8,9.8, 10.6, 10.7","norm_bases":["PN-EN ISO 3170:2025-12 z wyłączeniem 8.3.1.3 - 8.3.1.6, 8.3.1.8, 8.3.2, 8.7, 8.8,9.8, 10.6, 10.7"],"lab_section":"Punkt Obsługi Laboratoryjnej we Wrocławiu PP7/5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki, Biopaliwa ciekłe: estry metylowe kwasów tłuszczowych, bioetanol Pobieranie próbek ze zbiorników do badań chemicznych i fizycznych PN-EN ISO 3170:2025-12 z wyłączeniem 8.3.1.3 - 8.3.1.6, 8.3.1.8, 8.3.2, 8.7, 8.8,9.8, 10.6, 10.7 Paliwa ciekle: benzyna bezolowiowa, olej napedowy, olej opalowy lekki, Biopaliwa ciekle: estry metylowe kwasow tluszczowych, bioetanol Pobieranie probek ze zbiornikow do badan chemicznych i fizycznych PN-EN ISO 3170:2025-12 z wylaczeniem 8.3.1.3 - 8.3.1.6, 8.3.1.8, 8.3.2, 8.7, 8.8,9.8, 10.6, 10.7","categories":["petro"],"row_index":339,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb699","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy","methodology":"Pobieranie próbek z dystrybutora do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek z dystrybutora do badań chemicznych i fizycznych","reference":"PN-EN 14275:2013-06","norm_bases":["PN-EN 14275:2013-06"],"lab_section":"Punkt Obsługi Laboratoryjnej we Wrocławiu PP7/5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy Pobieranie próbek z dystrybutora do badań chemicznych i fizycznych PN-EN 14275:2013-06 Paliwa ciekle: benzyna bezolowiowa, olej napedowy Pobieranie probek z dystrybutora do badan chemicznych i fizycznych PN-EN 14275:2013-06","categories":["petro"],"row_index":340,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb69a","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki","methodology":"Zawartość siarki","parameters":[{"name":"Zakres","range":"(3,0 – 60) mg/kg"}],"technique":"Metoda fluorescencji w nadfiolecie","techniques":["Metoda fluorescencji w nadfiolecie"],"computed":[],"activity":"Zawartość siarki\nZakres (3,0 – 60) mg/kg\nMetoda fluorescencji w nadfiolecie","reference":"PN-EN ISO 20846:2020-03","norm_bases":["PN-EN ISO 20846:2020-03"],"lab_section":"Punkt Obsługi Laboratoryjnej we Wrocławiu PP7/5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki Zawartość siarki\nZakres (3,0 – 60) mg/kg\nMetoda fluorescencji w nadfiolecie PN-EN ISO 20846:2020-03 Paliwa ciekle: benzyna bezolowiowa, olej napedowy, olej opalowy lekki Zawartosc siarki\nZakres (3,0 – 60) mg/kg\nMetoda fluorescencji w nadfiolecie PN-EN ISO 20846:2020-03","categories":["petro"],"row_index":341,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb69b","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki","methodology":"Gęstość w temperaturze 15°C","parameters":[{"name":"Zakres","range":"(700,0 – 900,0) kg/m3"}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"computed":[],"activity":"Gęstość w temperaturze 15°C\nZakres (700,0 – 900,0) kg/m3\nMetoda oscylacyjna","reference":"PN-EN ISO 12185:2024-08","norm_bases":["PN-EN ISO 12185:2024-08"],"lab_section":"Punkt Obsługi Laboratoryjnej we Wrocławiu PP7/5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki Gęstość w temperaturze 15°C\nZakres (700,0 – 900,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08 Paliwa ciekle: benzyna bezolowiowa, olej napedowy, olej opalowy lekki Gestosc w temperaturze 15°C\nZakres (700,0 – 900,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08","categories":["petro"],"row_index":342,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb69c","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki","methodology":"Skład frakcyjny","parameters":[{"name":"Zakres","range":"(30,0 – 370,0) oC"}],"technique":"Metoda destylacyjna","techniques":["Metoda destylacyjna"],"computed":[],"activity":"Skład frakcyjny\nZakres (30,0 – 370,0) oC\nMetoda destylacyjna","reference":"PN-EN ISO 3405:2019-05","norm_bases":["PN-EN ISO 3405:2019-05"],"lab_section":"Punkt Obsługi Laboratoryjnej we Wrocławiu PP7/5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki Skład frakcyjny\nZakres (30,0 – 370,0) oC\nMetoda destylacyjna PN-EN ISO 3405:2019-05 Paliwa ciekle: benzyna bezolowiowa, olej napedowy, olej opalowy lekki Sklad frakcyjny\nZakres (30,0 – 370,0) oC\nMetoda destylacyjna PN-EN ISO 3405:2019-05","categories":["petro"],"row_index":343,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb69d","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Prężność par nasyconych powietrzem","parameters":[{"name":"Zakres","range":"(40,0 – 106,0) kPa"}],"technique":"Metoda mini Reid","techniques":["Metoda mini Reid"],"computed":[],"activity":"Prężność par nasyconych powietrzem\nZakres (40,0 – 106,0) kPa\nMetoda mini Reid","reference":"PN-EN 13016-1:2024-11","norm_bases":["PN-EN 13016-1:2024-11"],"lab_section":"Punkt Obsługi Laboratoryjnej we Wrocławiu PP7/5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Prężność par nasyconych powietrzem\nZakres (40,0 – 106,0) kPa\nMetoda mini Reid PN-EN 13016-1:2024-11 Paliwa ciekle: benzyna bezolowiowa Preznosc par nasyconych powietrzem\nZakres (40,0 – 106,0) kPa\nMetoda mini Reid PN-EN 13016-1:2024-11","categories":["petro","environment"],"row_index":344,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb69e","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Indeks lotności (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Indeks lotności (z obliczeń)","reference":"PN-EN 228+A1:2017-06 p. 5.5.2","norm_bases":["PN-EN 228+A1:2017-06 p. 5.5.2"],"lab_section":"Punkt Obsługi Laboratoryjnej we Wrocławiu PP7/5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Indeks lotności (z obliczeń) PN-EN 228+A1:2017-06 p. 5.5.2 Paliwa ciekle: benzyna bezolowiowa Indeks lotnosci (z obliczen) PN-EN 228+A1:2017-06 p. 5.5.2","categories":["petro"],"row_index":345,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb69f","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Zawartość tlenowych związków organicznych","parameters":[{"name":"Zakres","range":"(0,17 – 15,0) %(v/v)"},{"name":"Całkowita zawartość organicznie związanego tlenu (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość tlenowych związków organicznych\nZakres:\nZakres (0,17 – 15,0) %(v/v)\nCałkowita zawartość organicznie związanego tlenu (z obliczeń)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13132:2005","norm_bases":["PN-EN 13132:2005"],"lab_section":"Punkt Obsługi Laboratoryjnej we Wrocławiu PP7/5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Zawartość tlenowych związków organicznych\nZakres:\nZakres (0,17 – 15,0) %(v/v)\nCałkowita zawartość organicznie związanego tlenu (z obliczeń)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13132:2005 Paliwa ciekle: benzyna bezolowiowa Zawartosc tlenowych zwiazkow organicznych\nZakres:\nZakres (0,17 – 15,0) %(v/v)\nCalkowita zawartosc organicznie zwiazanego tlenu (z obliczen)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13132:2005","categories":["petro"],"row_index":346,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6a0","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki","methodology":"Temperatura zapłonu","parameters":[{"name":"Zakres","range":"(40,0 – 90,0) oC"}],"technique":"Metoda zamkniętego tygla Pensky’ego-Martensa","techniques":["Metoda zamkniętego tygla Pensky’ego-Martensa"],"computed":[],"activity":"Temperatura zapłonu\nZakres (40,0 – 90,0) oC\nMetoda zamkniętego tygla Pensky’ego-Martensa","reference":"PN-EN ISO 2719:2016-08+A1:2021-06","norm_bases":["PN-EN ISO 2719:2016-08+A1:2021-06"],"lab_section":"Punkt Obsługi Laboratoryjnej we Wrocławiu PP7/5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki Temperatura zapłonu\nZakres (40,0 – 90,0) oC\nMetoda zamkniętego tygla Pensky’ego-Martensa PN-EN ISO 2719:2016-08+A1:2021-06 Paliwa ciekle: olej napedowy, olej opalowy lekki Temperatura zaplonu\nZakres (40,0 – 90,0) oC\nMetoda zamknietego tygla Pensky’ego-Martensa PN-EN ISO 2719:2016-08+A1:2021-06","categories":["petro"],"row_index":347,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6a1","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki","methodology":"Zawartość wody","parameters":[{"name":"Zakres","range":"(30 – 1000) mg/kg"}],"technique":"Metoda miareczkowania kulometrycznego","techniques":["Metoda miareczkowania kulometrycznego"],"computed":[],"activity":"Zawartość wody\nZakres (30 – 1000) mg/kg\nMetoda miareczkowania kulometrycznego","reference":"PN-EN ISO 12937:2005+Ap1:2021-11","norm_bases":["PN-EN ISO 12937:2005+Ap1:2021-11"],"lab_section":"Punkt Obsługi Laboratoryjnej we Wrocławiu PP7/5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki Zawartość wody\nZakres (30 – 1000) mg/kg\nMetoda miareczkowania kulometrycznego PN-EN ISO 12937:2005+Ap1:2021-11 Paliwa ciekle: olej napedowy, olej opalowy lekki Zawartosc wody\nZakres (30 – 1000) mg/kg\nMetoda miareczkowania kulometrycznego PN-EN ISO 12937:2005+Ap1:2021-11","categories":["petro","water"],"row_index":348,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6a2","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki","methodology":"Zawartość zanieczyszczeń","parameters":[{"name":"Zakres","range":"(12,0 – 26,0) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość zanieczyszczeń\nZakres (12,0 – 26,0) mg/kg\nMetoda wagowa","reference":"PN-EN 12662-1:2024-11","norm_bases":["PN-EN 12662-1:2024-11"],"lab_section":"Punkt Obsługi Laboratoryjnej we Wrocławiu PP7/5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki Zawartość zanieczyszczeń\nZakres (12,0 – 26,0) mg/kg\nMetoda wagowa PN-EN 12662-1:2024-11 Paliwa ciekle: olej napedowy, olej opalowy lekki Zawartosc zanieczyszczen\nZakres (12,0 – 26,0) mg/kg\nMetoda wagowa PN-EN 12662-1:2024-11","categories":["petro"],"row_index":349,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6a3","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki","methodology":"Zawartość estrów metylowych kwasów tłuszczowych (FAME)","parameters":[{"name":"Zakres","range":"(3,0 – 20,0) %(v/v)"}],"technique":"Metoda spektrometrii w zakresie podczerwieni IR","techniques":["Metoda spektrometrii w zakresie podczerwieni IR"],"computed":[],"activity":"Zawartość estrów metylowych kwasów tłuszczowych (FAME)\nZakres (3,0 – 20,0) %(v/v)\nMetoda spektrometrii w zakresie podczerwieni IR","reference":"PN-EN 14078:2014-06","norm_bases":["PN-EN 14078:2014-06"],"lab_section":"Punkt Obsługi Laboratoryjnej we Wrocławiu PP7/5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki Zawartość estrów metylowych kwasów tłuszczowych (FAME)\nZakres (3,0 – 20,0) %(v/v)\nMetoda spektrometrii w zakresie podczerwieni IR PN-EN 14078:2014-06 Paliwa ciekle: olej napedowy, olej opalowy lekki Zawartosc estrow metylowych kwasow tluszczowych (FAME)\nZakres (3,0 – 20,0) %(v/v)\nMetoda spektrometrii w zakresie podczerwieni IR PN-EN 14078:2014-06","categories":["petro"],"row_index":350,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6a4","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Temperatura mętnienia","parameters":[{"name":"Zakres","range":"[(- 20) – 0] °C"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Temperatura mętnienia\nZakres [(- 20) – 0] °C\nMetoda optyczna","reference":"PN-EN ISO 3015:2019-06","norm_bases":["PN-EN ISO 3015:2019-06"],"lab_section":"Punkt Obsługi Laboratoryjnej we Wrocławiu PP7/5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Temperatura mętnienia\nZakres [(- 20) – 0] °C\nMetoda optyczna PN-EN ISO 3015:2019-06 Paliwa ciekle: olej napedowy, olej opalowy lekki, biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Temperatura metnienia\nZakres [(- 20) – 0] °C\nMetoda optyczna PN-EN ISO 3015:2019-06","categories":["petro"],"row_index":351,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6a5","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy","methodology":"Stabilność oksydacyjna","parameters":[{"name":"Zakres","range":"(5,0 – 48,0) h"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Stabilność oksydacyjna\nZakres (5,0 – 48,0) h\nMetoda konduktometryczna","reference":"PN-EN 15751:2014-05","norm_bases":["PN-EN 15751:2014-05"],"lab_section":"Punkt Obsługi Laboratoryjnej we Wrocławiu PP7/5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy Stabilność oksydacyjna\nZakres (5,0 – 48,0) h\nMetoda konduktometryczna PN-EN 15751:2014-05 Paliwa ciekle: olej napedowy Stabilnosc oksydacyjna\nZakres (5,0 – 48,0) h\nMetoda konduktometryczna PN-EN 15751:2014-05","categories":["petro"],"row_index":352,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6a6","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy","methodology":"Temperatura zablokowania zimnego filtra","parameters":[{"name":"Zakres","range":"[(- 40) – 0] °C"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Temperatura zablokowania zimnego filtra\nZakres [(- 40) – 0] °C\nMetoda optyczna","reference":"PN-EN 116:2015-09","norm_bases":["PN-EN 116:2015-09"],"lab_section":"Punkt Obsługi Laboratoryjnej we Wrocławiu PP7/5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy Temperatura zablokowania zimnego filtra\nZakres [(- 40) – 0] °C\nMetoda optyczna PN-EN 116:2015-09 Paliwa ciekle: olej napedowy Temperatura zablokowania zimnego filtra\nZakres [(- 40) – 0] °C\nMetoda optyczna PN-EN 116:2015-09","categories":["petro"],"row_index":353,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6a7","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy","methodology":"Indeks cetanowy (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Indeks cetanowy (z obliczeń)","reference":"PN-EN ISO 4264:2018-08","norm_bases":["PN-EN ISO 4264:2018-08"],"lab_section":"Punkt Obsługi Laboratoryjnej we Wrocławiu PP7/5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy Indeks cetanowy (z obliczeń) PN-EN ISO 4264:2018-08 Paliwa ciekle: olej napedowy Indeks cetanowy (z obliczen) PN-EN ISO 4264:2018-08","categories":["petro"],"row_index":354,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6a8","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej opałowy lekki","methodology":"Temperatura płynięcia","parameters":[{"name":"[(- 45)","range":"(-15)] °C"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Temperatura płynięcia\n[(- 45) (-15)] °C\nMetoda optyczna","reference":"PN-EN ISO 3016:2019-06","norm_bases":["PN-EN ISO 3016:2019-06"],"lab_section":"Punkt Obsługi Laboratoryjnej we Wrocławiu PP7/5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej opałowy lekki Temperatura płynięcia\n[(- 45) (-15)] °C\nMetoda optyczna PN-EN ISO 3016:2019-06 Paliwa ciekle: olej opalowy lekki Temperatura plyniecia\n[(- 45) (-15)] °C\nMetoda optyczna PN-EN ISO 3016:2019-06","categories":["petro"],"row_index":355,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6a9","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej opałowy lekki","methodology":"Zawartość barwnika Solvent Red 19","parameters":[{"name":"Zakres","range":"(1,0 – 10,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość barwnika Solvent Red 19\nZakres (1,0 – 10,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-C-04426:2013-07 Metoda A","norm_bases":["PN-C-04426:2013-07 Metoda A"],"lab_section":"Punkt Obsługi Laboratoryjnej we Wrocławiu PP7/5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej opałowy lekki Zawartość barwnika Solvent Red 19\nZakres (1,0 – 10,0) mg/l\nMetoda spektrofotometryczna PN-C-04426:2013-07 Metoda A Paliwa ciekle: olej opalowy lekki Zawartosc barwnika Solvent Red 19\nZakres (1,0 – 10,0) mg/l\nMetoda spektrofotometryczna PN-C-04426:2013-07 Metoda A","categories":["petro"],"row_index":356,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6aa","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość siarki","parameters":[{"name":"Zakres","range":"(3,0 – 10,0) mg/kg"}],"technique":"Metoda fluorescencji w nadfiolecie","techniques":["Metoda fluorescencji w nadfiolecie"],"computed":[],"activity":"Zawartość siarki\nZakres (3,0 – 10,0) mg/kg\nMetoda fluorescencji w nadfiolecie","reference":"PN-EN ISO 20846:2020-03","norm_bases":["PN-EN ISO 20846:2020-03"],"lab_section":"Punkt Obsługi Laboratoryjnej we Wrocławiu PP7/5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Zawartość siarki\nZakres (3,0 – 10,0) mg/kg\nMetoda fluorescencji w nadfiolecie PN-EN ISO 20846:2020-03 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Zawartosc siarki\nZakres (3,0 – 10,0) mg/kg\nMetoda fluorescencji w nadfiolecie PN-EN ISO 20846:2020-03","categories":["petro"],"row_index":357,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6ab","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Temperatura zablokowania zimnego filtra","parameters":[{"name":"Zakres","range":"[(- 20) – 0] °C"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Temperatura zablokowania zimnego filtra\nZakres [(- 20) – 0] °C\nMetoda optyczna","reference":"PN-EN 116:2015-09","norm_bases":["PN-EN 116:2015-09"],"lab_section":"Punkt Obsługi Laboratoryjnej we Wrocławiu PP7/5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Temperatura zablokowania zimnego filtra\nZakres [(- 20) – 0] °C\nMetoda optyczna PN-EN 116:2015-09 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Temperatura zablokowania zimnego filtra\nZakres [(- 20) – 0] °C\nMetoda optyczna PN-EN 116:2015-09","categories":["petro"],"row_index":358,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6ac","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość wody","parameters":[{"name":"Zakres","range":"(30 – 1000) mg/kg"}],"technique":"Metoda miareczkowania kulometrycznego","techniques":["Metoda miareczkowania kulometrycznego"],"computed":[],"activity":"Zawartość wody\nZakres (30 – 1000) mg/kg\nMetoda miareczkowania kulometrycznego","reference":"PN-EN ISO 12937:2005+Ap1:2021-11","norm_bases":["PN-EN ISO 12937:2005+Ap1:2021-11"],"lab_section":"Punkt Obsługi Laboratoryjnej we Wrocławiu PP7/5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Zawartość wody\nZakres (30 – 1000) mg/kg\nMetoda miareczkowania kulometrycznego PN-EN ISO 12937:2005+Ap1:2021-11 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Zawartosc wody\nZakres (30 – 1000) mg/kg\nMetoda miareczkowania kulometrycznego PN-EN ISO 12937:2005+Ap1:2021-11","categories":["petro","water"],"row_index":359,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6ad","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Gęstość w temp. 15 °C","parameters":[{"name":"Zakres","range":"(850 – 900) kg/m3"}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"computed":[],"activity":"Gęstość w temp. 15 °C\nZakres (850 – 900) kg/m3\nMetoda oscylacyjna","reference":"PN-EN ISO 12185:2024-08","norm_bases":["PN-EN ISO 12185:2024-08"],"lab_section":"Punkt Obsługi Laboratoryjnej we Wrocławiu PP7/5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Gęstość w temp. 15 °C\nZakres (850 – 900) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Gestosc w temp. 15 °C\nZakres (850 – 900) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08","categories":["petro"],"row_index":360,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6ae","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Skłonność do blokowania filtra po wychładzaniu","parameters":[{"name":"Zakres","range":"(50 – 720) s"}],"technique":"Metoda filtracji po wychłodzeniu","techniques":["Metoda filtracji po wychłodzeniu"],"computed":[],"activity":"Skłonność do blokowania filtra po wychładzaniu\nZakres (50 – 720) s\nMetoda filtracji po wychłodzeniu","reference":"ASTM D 7501-22","norm_bases":["ASTM D 7501-22"],"lab_section":"Punkt Obsługi Laboratoryjnej we Wrocławiu PP7/5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Skłonność do blokowania filtra po wychładzaniu\nZakres (50 – 720) s\nMetoda filtracji po wychłodzeniu ASTM D 7501-22 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Sklonnosc do blokowania filtra po wychladzaniu\nZakres (50 – 720) s\nMetoda filtracji po wychlodzeniu ASTM D 7501-22","categories":["petro"],"row_index":361,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6af","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Stabilność oksydacyjna","parameters":[{"name":"Zakres","range":"(1,0 – 16,0) h"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Stabilność oksydacyjna\nZakres (1,0 – 16,0) h\nMetoda konduktometryczna","reference":"PN-EN 15751:2014-05","norm_bases":["PN-EN 15751:2014-05"],"lab_section":"Punkt Obsługi Laboratoryjnej we Wrocławiu PP7/5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Stabilność oksydacyjna\nZakres (1,0 – 16,0) h\nMetoda konduktometryczna PN-EN 15751:2014-05 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Stabilnosc oksydacyjna\nZakres (1,0 – 16,0) h\nMetoda konduktometryczna PN-EN 15751:2014-05","categories":["petro"],"row_index":362,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6b0","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość zanieczyszczeń","parameters":[{"name":"Zakres","range":"(5,0 – 27,0) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość zanieczyszczeń\nZakres (5,0 – 27,0) mg/kg\nMetoda wagowa","reference":"PN-EN 12662-2:2024-11","norm_bases":["PN-EN 12662-2:2024-11"],"lab_section":"Punkt Obsługi Laboratoryjnej we Wrocławiu PP7/5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Zawartość zanieczyszczeń\nZakres (5,0 – 27,0) mg/kg\nMetoda wagowa PN-EN 12662-2:2024-11 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Zawartosc zanieczyszczen\nZakres (5,0 – 27,0) mg/kg\nMetoda wagowa PN-EN 12662-2:2024-11","categories":["petro"],"row_index":363,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6b1","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: bioetanol","methodology":"Moc","parameters":[{"name":"Zakres","range":"(95,0 – 100,0) %(v/v)"}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"computed":[],"activity":"Moc\nZakres (95,0 – 100,0) %(v/v)\nMetoda oscylacyjna","reference":"PN-A-79528-3:2007 p. 5.2","norm_bases":["PN-A-79528-3:2007 p. 5.2"],"lab_section":"Punkt Obsługi Laboratoryjnej we Wrocławiu PP7/5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: bioetanol Moc\nZakres (95,0 – 100,0) %(v/v)\nMetoda oscylacyjna PN-A-79528-3:2007 p. 5.2 Paliwa ciekle: biopaliwa ciekle: bioetanol Moc\nZakres (95,0 – 100,0) %(v/v)\nMetoda oscylacyjna PN-A-79528-3:2007 p. 5.2","categories":["petro"],"row_index":364,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6b2","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: bioetanol","methodology":"Gęstość w temperaturze 20°C","parameters":[{"name":"Zakres","range":"(789,0 – 830,0) kg/m3"}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"computed":[],"activity":"Gęstość w temperaturze 20°C\nZakres (789,0 – 830,0) kg/m3\nMetoda oscylacyjna","reference":"PN-EN ISO 12185:2024-08","norm_bases":["PN-EN ISO 12185:2024-08"],"lab_section":"Punkt Obsługi Laboratoryjnej we Wrocławiu PP7/5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: bioetanol Gęstość w temperaturze 20°C\nZakres (789,0 – 830,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08 Paliwa ciekle: biopaliwa ciekle: bioetanol Gestosc w temperaturze 20°C\nZakres (789,0 – 830,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08","categories":["petro"],"row_index":365,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6b3","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Liczba oktanowa LOM","parameters":[{"name":"Zakres","range":"80,0 – 90,0"}],"technique":"Metoda silnikowa","techniques":["Metoda silnikowa"],"computed":[],"activity":"Liczba oktanowa LOM\nZakres 80,0 – 90,0\nMetoda silnikowa","reference":"PN-EN ISO 5163:2014-08","norm_bases":["PN-EN ISO 5163:2014-08"],"lab_section":"Punkt Obsługi Laboratoryjnej we Wrocławiu PP7/5 (Działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Liczba oktanowa LOM\nZakres 80,0 – 90,0\nMetoda silnikowa PN-EN ISO 5163:2014-08 Paliwa ciekle: benzyna bezolowiowa Liczba oktanowa LOM\nZakres 80,0 – 90,0\nMetoda silnikowa PN-EN ISO 5163:2014-08","categories":["petro"],"row_index":366,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6b4","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, olej opałowy lekki, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Pobieranie próbek ze zbiorników do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek ze zbiorników do badań chemicznych i fizycznych","reference":"PN-EN ISO 3170:2025-12 z wyłączeniem pkt 8.3.1.3- 8.3.1.5, 8.3.1.8, 8.3.2, 8.5 - 8.9, 9.8, 10.6, 10.7","norm_bases":["PN-EN ISO 3170:2025-12 z wyłączeniem pkt 8.3.1.3- 8.3.1.5, 8.3.1.8, 8.3.2, 8.5 - 8.9, 9.8, 10.6, 10.7"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, olej opałowy lekki, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Pobieranie próbek ze zbiorników do badań chemicznych i fizycznych PN-EN ISO 3170:2025-12 z wyłączeniem pkt 8.3.1.3- 8.3.1.5, 8.3.1.8, 8.3.2, 8.5 - 8.9, 9.8, 10.6, 10.7 Paliwa ciekle: olej napedowy, benzyna bezolowiowa, olej opalowy lekki, biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Pobieranie probek ze zbiornikow do badan chemicznych i fizycznych PN-EN ISO 3170:2025-12 z wylaczeniem pkt 8.3.1.3- 8.3.1.5, 8.3.1.8, 8.3.2, 8.5 - 8.9, 9.8, 10.6, 10.7","categories":["petro"],"row_index":367,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6b5","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej opałowy lekki, olej opałowy ciężki, Materiały smarne: olej silnikowy, przemysłowe oleje smarowe","methodology":"Temperatura płynięcia","parameters":[{"name":"Zakres","range":"(–38 – 40) °C"}],"technique":"Metoda optyczna, metoda wizualna","techniques":["Metoda optyczna, metoda wizualna"],"computed":[],"activity":"Temperatura płynięcia\nZakres (–38 – 40) °C\nMetoda optyczna, metoda wizualna","reference":"PN-EN ISO 3016:2019-06 | ASTM D 97-17b(2022)","norm_bases":["PN-EN ISO 3016:2019-06","ASTM D 97-17b(2022)"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej opałowy lekki, olej opałowy ciężki, Materiały smarne: olej silnikowy, przemysłowe oleje smarowe Temperatura płynięcia\nZakres (–38 – 40) °C\nMetoda optyczna, metoda wizualna PN-EN ISO 3016:2019-06 | ASTM D 97-17b(2022) Paliwa ciekle: olej opalowy lekki, olej opalowy ciezki, Materialy smarne: olej silnikowy, przemyslowe oleje smarowe Temperatura plyniecia\nZakres (–38 – 40) °C\nMetoda optyczna, metoda wizualna PN-EN ISO 3016:2019-06 | ASTM D 97-17b(2022)","categories":["petro","materials"],"row_index":368,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6b6","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej opałowy lekki, olej opałowy ciężki, Materiały smarne: olej silnikowy, przemysłowe oleje smarowe","methodology":"Zawartość siarki","parameters":[{"name":"Zakres","range":"(0,050 – 1,00) %(m/m)"}],"technique":"Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii","techniques":["Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii"],"computed":[],"activity":"Zawartość siarki\nZakres (0,050 – 1,00) %(m/m)\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii","reference":"PN –EN ISO 8754:2007+Ap1:2014-02","norm_bases":["PN –EN ISO 8754:2007+Ap1:2014-02"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej opałowy lekki, olej opałowy ciężki, Materiały smarne: olej silnikowy, przemysłowe oleje smarowe Zawartość siarki\nZakres (0,050 – 1,00) %(m/m)\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii PN –EN ISO 8754:2007+Ap1:2014-02 Paliwa ciekle: olej opalowy lekki, olej opalowy ciezki, Materialy smarne: olej silnikowy, przemyslowe oleje smarowe Zawartosc siarki\nZakres (0,050 – 1,00) %(m/m)\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersja energii PN –EN ISO 8754:2007+Ap1:2014-02","categories":["petro","materials"],"row_index":369,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6b7","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, olej opałowy lekki, olej opałowy ciężki, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME), Materiały smarne: olej silnikowy, przemysłowe oleje smarowe","methodology":"Gęstość","parameters":[{"name":"Zakres","range":"(700,0 – 950,0) kg/m3"}],"technique":"Metoda areometryczna","techniques":["Metoda areometryczna"],"computed":[],"activity":"Gęstość\nZakres (700,0 – 950,0) kg/m3\nMetoda areometryczna","reference":"PN-EN ISO 3675:2004","norm_bases":["PN-EN ISO 3675:2004"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, olej opałowy lekki, olej opałowy ciężki, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME), Materiały smarne: olej silnikowy, przemysłowe oleje smarowe Gęstość\nZakres (700,0 – 950,0) kg/m3\nMetoda areometryczna PN-EN ISO 3675:2004 Paliwa ciekle: olej napedowy, benzyna bezolowiowa, olej opalowy lekki, olej opalowy ciezki, biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME), Materialy smarne: olej silnikowy, przemyslowe oleje smarowe Gestosc\nZakres (700,0 – 950,0) kg/m3\nMetoda areometryczna PN-EN ISO 3675:2004","categories":["petro","materials"],"row_index":370,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6b8","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, olej opałowy lekki, olej opałowy ciężki, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME), Materiały smarne: olej silnikowy, przemysłowe oleje smarowe","methodology":"Gęstość w temperaturze 15°C i 20°C","parameters":[{"name":"Zakres","range":"(700,0 – 900,0) kg/m3"}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"computed":[],"activity":"Gęstość w temperaturze 15°C i 20°C\nZakres (700,0 – 900,0) kg/m3\nMetoda oscylacyjna","reference":"PN-EN ISO 12185:2024-08 | ASTM D 4052-22","norm_bases":["PN-EN ISO 12185:2024-08","ASTM D 4052-22"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, olej opałowy lekki, olej opałowy ciężki, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME), Materiały smarne: olej silnikowy, przemysłowe oleje smarowe Gęstość w temperaturze 15°C i 20°C\nZakres (700,0 – 900,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08 | ASTM D 4052-22 Paliwa ciekle: olej napedowy, benzyna bezolowiowa, olej opalowy lekki, olej opalowy ciezki, biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME), Materialy smarne: olej silnikowy, przemyslowe oleje smarowe Gestosc w temperaturze 15°C i 20°C\nZakres (700,0 – 900,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08 | ASTM D 4052-22","categories":["petro","materials"],"row_index":371,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6b9","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, olej opałowy ciężki, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME), Materiały smarne: olej silnikowy, przemysłowe oleje smarowe","methodology":"Lepkość kinematyczna w temperaturze 20°C, 40°C i 100°C","parameters":[{"name":"Zakres","range":"(1,500 – 100,0) mm2/s"},{"name":"Lepkość dynamiczna (z obliczeń)"}],"technique":"Metoda kapilarna","techniques":["Metoda kapilarna"],"computed":[],"activity":"Lepkość kinematyczna w temperaturze 20°C, 40°C i 100°C\nZakres:\nZakres (1,500 – 100,0) mm2/s\nLepkość dynamiczna (z obliczeń)\nMetoda kapilarna","reference":"PN-EN ISO 3104:2024-01","norm_bases":["PN-EN ISO 3104:2024-01"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, olej opałowy ciężki, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME), Materiały smarne: olej silnikowy, przemysłowe oleje smarowe Lepkość kinematyczna w temperaturze 20°C, 40°C i 100°C\nZakres:\nZakres (1,500 – 100,0) mm2/s\nLepkość dynamiczna (z obliczeń)\nMetoda kapilarna PN-EN ISO 3104:2024-01 Paliwa ciekle: olej napedowy, olej opalowy lekki, olej opalowy ciezki, biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME), Materialy smarne: olej silnikowy, przemyslowe oleje smarowe Lepkosc kinematyczna w temperaturze 20°C, 40°C i 100°C\nZakres:\nZakres (1,500 – 100,0) mm2/s\nLepkosc dynamiczna (z obliczen)\nMetoda kapilarna PN-EN ISO 3104:2024-01","categories":["petro","materials"],"row_index":372,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6ba","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, olej opałowy ciężki, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME), Materiały smarne: olej silnikowy, przemysłowe oleje smarowe","methodology":"Lepkość kinematyczna w temp. 20 °C, 40 °C i 100 °C","parameters":[{"name":"Zakres","range":"(1,500 – 100,0) mm2/s"}],"technique":"Metoda kapilarna","techniques":["Metoda kapilarna"],"computed":[],"activity":"Lepkość kinematyczna w temp. 20 °C, 40 °C i 100 °C\nZakres (1,500 – 100,0) mm2/s\nMetoda kapilarna","reference":"ASTM D 445-24","norm_bases":["ASTM D 445-24"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, olej opałowy ciężki, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME), Materiały smarne: olej silnikowy, przemysłowe oleje smarowe Lepkość kinematyczna w temp. 20 °C, 40 °C i 100 °C\nZakres (1,500 – 100,0) mm2/s\nMetoda kapilarna ASTM D 445-24 Paliwa ciekle: olej napedowy, olej opalowy lekki, olej opalowy ciezki, biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME), Materialy smarne: olej silnikowy, przemyslowe oleje smarowe Lepkosc kinematyczna w temp. 20 °C, 40 °C i 100 °C\nZakres (1,500 – 100,0) mm2/s\nMetoda kapilarna ASTM D 445-24","categories":["petro","materials"],"row_index":373,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6bb","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość wody","parameters":[{"name":"Zakres","range":"(0,003 – 0,100) %(m/m)"}],"technique":"Metoda miareczkowania kulometrycznego","techniques":["Metoda miareczkowania kulometrycznego"],"computed":[],"activity":"Zawartość wody\nZakres (0,003 – 0,100) %(m/m)\nMetoda miareczkowania kulometrycznego","reference":"PN-EN ISO 12937:2005+Ap1:2021-11","norm_bases":["PN-EN ISO 12937:2005+Ap1:2021-11"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Zawartość wody\nZakres (0,003 – 0,100) %(m/m)\nMetoda miareczkowania kulometrycznego PN-EN ISO 12937:2005+Ap1:2021-11 Paliwa ciekle: olej napedowy, olej opalowy lekki, biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Zawartosc wody\nZakres (0,003 – 0,100) %(m/m)\nMetoda miareczkowania kulometrycznego PN-EN ISO 12937:2005+Ap1:2021-11","categories":["petro","water"],"row_index":374,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6bc","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Pozostałość po koksowaniu","parameters":[{"name":"Zakres","range":"(0,10 – 3,50) %(m/m)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Pozostałość po koksowaniu\nZakres (0,10 – 3,50) %(m/m)\nMetoda wagowa","reference":"PN-EN ISO 10370:2014-12","norm_bases":["PN-EN ISO 10370:2014-12"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Pozostałość po koksowaniu\nZakres (0,10 – 3,50) %(m/m)\nMetoda wagowa PN-EN ISO 10370:2014-12 Paliwa ciekle: olej napedowy, olej opalowy lekki, biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Pozostalosc po koksowaniu\nZakres (0,10 – 3,50) %(m/m)\nMetoda wagowa PN-EN ISO 10370:2014-12","categories":["petro"],"row_index":375,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6bd","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Temp. zablokowania zimnego filtru","parameters":[{"name":"Zakres","range":"(0 – (–30)) °C"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Temp. zablokowania zimnego filtru\nZakres (0 – (–30)) °C\nMetoda optyczna","reference":"PN-EN 116:2015-09","norm_bases":["PN-EN 116:2015-09"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Temp. zablokowania zimnego filtru\nZakres (0 – (–30)) °C\nMetoda optyczna PN-EN 116:2015-09 Paliwa ciekle: olej napedowy, olej opalowy lekki, biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Temp. zablokowania zimnego filtru\nZakres (0 – (–30)) °C\nMetoda optyczna PN-EN 116:2015-09","categories":["petro"],"row_index":376,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6be","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Temperatura mętnienia","parameters":[{"name":"Zakres","range":"(-38) – (+10) °C"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Temperatura mętnienia\nZakres (-38) – (+10) °C\nMetoda optyczna","reference":"PN-EN ISO 3015:2019-06","norm_bases":["PN-EN ISO 3015:2019-06"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Temperatura mętnienia\nZakres (-38) – (+10) °C\nMetoda optyczna PN-EN ISO 3015:2019-06 Paliwa ciekle: olej napedowy, olej opalowy lekki, biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Temperatura metnienia\nZakres (-38) – (+10) °C\nMetoda optyczna PN-EN ISO 3015:2019-06","categories":["petro"],"row_index":377,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6bf","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki","methodology":"Zawartość zanieczyszczeń","parameters":[{"name":"Zakres","range":"(12,0 – 26,0) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość zanieczyszczeń\nZakres (12,0 – 26,0) mg/kg\nMetoda wagowa","reference":"PN-EN 12662-1:2024-11","norm_bases":["PN-EN 12662-1:2024-11"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki Zawartość zanieczyszczeń\nZakres (12,0 – 26,0) mg/kg\nMetoda wagowa PN-EN 12662-1:2024-11 Paliwa ciekle: olej napedowy, olej opalowy lekki Zawartosc zanieczyszczen\nZakres (12,0 – 26,0) mg/kg\nMetoda wagowa PN-EN 12662-1:2024-11","categories":["petro"],"row_index":378,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6c0","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość zanieczyszczeń","parameters":[{"name":"Zakres","range":"(5,0 – 27,0) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość zanieczyszczeń\nZakres (5,0 – 27,0) mg/kg\nMetoda wagowa","reference":"PN-EN 12662-2:2024-11","norm_bases":["PN-EN 12662-2:2024-11"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Zawartość zanieczyszczeń\nZakres (5,0 – 27,0) mg/kg\nMetoda wagowa PN-EN 12662-2:2024-11 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Zawartosc zanieczyszczen\nZakres (5,0 – 27,0) mg/kg\nMetoda wagowa PN-EN 12662-2:2024-11","categories":["petro"],"row_index":379,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6c1","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość siarki","parameters":[{"name":"Zakres","range":"(1,0 – 20,0) mg/kg"}],"technique":"Metoda fluorescencji w nadfiolecie","techniques":["Metoda fluorescencji w nadfiolecie"],"computed":[],"activity":"Zawartość siarki\nZakres (1,0 – 20,0) mg/kg\nMetoda fluorescencji w nadfiolecie","reference":"PN-EN ISO 20846:2020-03","norm_bases":["PN-EN ISO 20846:2020-03"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Zawartość siarki\nZakres (1,0 – 20,0) mg/kg\nMetoda fluorescencji w nadfiolecie PN-EN ISO 20846:2020-03 Paliwa ciekle: olej napedowy, benzyna bezolowiowa, biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Zawartosc siarki\nZakres (1,0 – 20,0) mg/kg\nMetoda fluorescencji w nadfiolecie PN-EN ISO 20846:2020-03","categories":["petro"],"row_index":380,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6c2","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME), Materiały smarne: olej silnikowy, przemysłowe oleje smarowe","methodology":"Zawartość popiołu siarczanowego","parameters":[{"name":"Zakres","range":"(0,005 – 2,00) %(m/m)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość popiołu siarczanowego\nZakres (0,005 – 2,00) %(m/m)\nMetoda wagowa","reference":"PN ISO 3987:2014-05","norm_bases":["PN ISO 3987:2014-05"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME), Materiały smarne: olej silnikowy, przemysłowe oleje smarowe Zawartość popiołu siarczanowego\nZakres (0,005 – 2,00) %(m/m)\nMetoda wagowa PN ISO 3987:2014-05 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME), Materialy smarne: olej silnikowy, przemyslowe oleje smarowe Zawartosc popiolu siarczanowego\nZakres (0,005 – 2,00) %(m/m)\nMetoda wagowa PN ISO 3987:2014-05","categories":["petro","materials"],"row_index":381,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6c3","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, olej opałowy ciężki","methodology":"Temperatura zapłonu","parameters":[{"name":"Zakres","range":"(40,0 – 250,0) °C"},{"name":"Pensky’ego-Martensa"}],"technique":"Metoda zamkniętego tygla","techniques":["Metoda zamkniętego tygla"],"computed":[],"activity":"Temperatura zapłonu\nZakres:\nZakres (40,0 – 250,0) °C\nPensky’ego-Martensa\nMetoda zamkniętego tygla","reference":"PN-EN ISO 2719:2016-08+A1: 2021-06 z wyłączeniem procedury C | ASTM D 93-25","norm_bases":["PN-EN ISO 2719:2016-08+A1: 2021-06 z wyłączeniem procedury C","ASTM D 93-25"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, olej opałowy ciężki Temperatura zapłonu\nZakres:\nZakres (40,0 – 250,0) °C\nPensky’ego-Martensa\nMetoda zamkniętego tygla PN-EN ISO 2719:2016-08+A1: 2021-06 z wyłączeniem procedury C | ASTM D 93-25 Paliwa ciekle: olej napedowy, olej opalowy lekki, olej opalowy ciezki Temperatura zaplonu\nZakres:\nZakres (40,0 – 250,0) °C\nPensky’ego-Martensa\nMetoda zamknietego tygla PN-EN ISO 2719:2016-08+A1: 2021-06 z wylaczeniem procedury C | ASTM D 93-25","categories":["petro"],"row_index":382,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6c4","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME), Materiały smarne: olej silnikowy, przemysłowe oleje smarowe","methodology":"Korozja na miedzi","parameters":[{"name":"klasa korozji","range":"(1 – 4)"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Korozja na miedzi\nklasa korozji (1 – 4)\nMetoda wizualna","reference":"PN-EN ISO 2160:2004 | ASTM D 130-19","norm_bases":["PN-EN ISO 2160:2004","ASTM D 130-19"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME), Materiały smarne: olej silnikowy, przemysłowe oleje smarowe Korozja na miedzi\nklasa korozji (1 – 4)\nMetoda wizualna PN-EN ISO 2160:2004 | ASTM D 130-19 Paliwa ciekle: benzyna bezolowiowa, biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME), Materialy smarne: olej silnikowy, przemyslowe oleje smarowe Korozja na miedzi\nklasa korozji (1 – 4)\nMetoda wizualna PN-EN ISO 2160:2004 | ASTM D 130-19","categories":["petro","materials"],"row_index":383,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6c5","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy","methodology":"Zawartość estrów metylowych kwasów tłuszczowych FAME","parameters":[{"name":"Zakres","range":"(0,05 – 10,0) %(v/v)"}],"technique":"Metoda spektrometrii w zakresie podczerwieni IR","techniques":["Metoda spektrometrii w zakresie podczerwieni IR"],"computed":[],"activity":"Zawartość estrów metylowych kwasów tłuszczowych FAME\nZakres (0,05 – 10,0) %(v/v)\nMetoda spektrometrii w zakresie podczerwieni IR","reference":"PN-EN 14078:2014-06","norm_bases":["PN-EN 14078:2014-06"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy Zawartość estrów metylowych kwasów tłuszczowych FAME\nZakres (0,05 – 10,0) %(v/v)\nMetoda spektrometrii w zakresie podczerwieni IR PN-EN 14078:2014-06 Paliwa ciekle: olej napedowy Zawartosc estrow metylowych kwasow tluszczowych FAME\nZakres (0,05 – 10,0) %(v/v)\nMetoda spektrometrii w zakresie podczerwieni IR PN-EN 14078:2014-06","categories":["petro"],"row_index":384,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6c6","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa","methodology":"Skład frakcyjny","parameters":[{"name":"Zakres","range":"(40,0 – 360,0) 0C"}],"technique":"Metoda destylacyjna","techniques":["Metoda destylacyjna"],"computed":[],"activity":"Skład frakcyjny\nZakres (40,0 – 360,0) 0C\nMetoda destylacyjna","reference":"PN-EN ISO 3405:2019-05","norm_bases":["PN-EN ISO 3405:2019-05"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa Skład frakcyjny\nZakres (40,0 – 360,0) 0C\nMetoda destylacyjna PN-EN ISO 3405:2019-05 Paliwa ciekle: olej napedowy, benzyna bezolowiowa Sklad frakcyjny\nZakres (40,0 – 360,0) 0C\nMetoda destylacyjna PN-EN ISO 3405:2019-05","categories":["petro"],"row_index":385,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6c7","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej opałowy lekki, olej opałowy ciężki","methodology":"Ciepło spalania","parameters":[{"name":"Zakres","range":"(35000 – 45000) kJ/kg"},{"name":"Wartość opałowa (z obliczeń)"}],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna"],"computed":[],"activity":"Ciepło spalania\nZakres:\nZakres (35000 – 45000) kJ/kg\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna","reference":"PN-C-04062:2018-05","norm_bases":["PN-C-04062:2018-05"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej opałowy lekki, olej opałowy ciężki Ciepło spalania\nZakres:\nZakres (35000 – 45000) kJ/kg\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna PN-C-04062:2018-05 Paliwa ciekle: olej opalowy lekki, olej opalowy ciezki Cieplo spalania\nZakres:\nZakres (35000 – 45000) kJ/kg\nWartosc opalowa (z obliczen)\nMetoda kalorymetryczna PN-C-04062:2018-05","categories":["petro"],"row_index":386,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6c8","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej opałowy ciężki","methodology":"Zawartość żelaza, wanadu i niklu","parameters":[{"name":"Fe","range":"(1,00 – 150) mg/kg"},{"name":"V","range":"(1,00 – 150) mg/kg"},{"name":"Ni","range":"(1,00 – 150) mg/kg"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnej sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnej sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość żelaza, wanadu i niklu\nZakres:\nFe (1,00 – 150) mg/kg\nV (1,00 – 150) mg/kg\nNi (1,00 – 150) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnej sprzężonej (ICP-OES)","reference":"ASTM D 5708-15 (Reapproved 2020)e1 – Metoda A","norm_bases":["ASTM D 5708-15 (Reapproved 2020)e1 – Metoda A"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej opałowy ciężki Zawartość żelaza, wanadu i niklu\nZakres:\nFe (1,00 – 150) mg/kg\nV (1,00 – 150) mg/kg\nNi (1,00 – 150) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnej sprzężonej (ICP-OES) ASTM D 5708-15 (Reapproved 2020)e1 – Metoda A Paliwa ciekle: olej opalowy ciezki Zawartosc zelaza, wanadu i niklu\nZakres:\nFe (1,00 – 150) mg/kg\nV (1,00 – 150) mg/kg\nNi (1,00 – 150) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnej sprzezonej (ICP-OES) ASTM D 5708-15 (Reapproved 2020)e1 – Metoda A","categories":["petro"],"row_index":387,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6c9","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Zawartość tlenowych związków organicznych","parameters":[{"name":"Zakres","range":"(0,17 – 15,0) %(m/m), %(v/v)"},{"name":"Całkowita zawartość organicznie związanego tlenu (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość tlenowych związków organicznych\nZakres:\nZakres (0,17 – 15,0) %(m/m), %(v/v)\nCałkowita zawartość organicznie związanego tlenu (z obliczeń)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13132:2005","norm_bases":["PN-EN 13132:2005"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Zawartość tlenowych związków organicznych\nZakres:\nZakres (0,17 – 15,0) %(m/m), %(v/v)\nCałkowita zawartość organicznie związanego tlenu (z obliczeń)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13132:2005 Paliwa ciekle: benzyna bezolowiowa Zawartosc tlenowych zwiazkow organicznych\nZakres:\nZakres (0,17 – 15,0) %(m/m), %(v/v)\nCalkowita zawartosc organicznie zwiazanego tlenu (z obliczen)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13132:2005","categories":["petro"],"row_index":388,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6ca","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Prężność par nasyconych powietrzem","parameters":[{"name":"Zakres","range":"(30,0 – 106,0) kPa"}],"technique":"Metoda mini Reid","techniques":["Metoda mini Reid"],"computed":[],"activity":"Prężność par nasyconych powietrzem\nZakres (30,0 – 106,0) kPa\nMetoda mini Reid","reference":"PN-EN 13016-1:2024-11","norm_bases":["PN-EN 13016-1:2024-11"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Prężność par nasyconych powietrzem\nZakres (30,0 – 106,0) kPa\nMetoda mini Reid PN-EN 13016-1:2024-11 Paliwa ciekle: benzyna bezolowiowa Preznosc par nasyconych powietrzem\nZakres (30,0 – 106,0) kPa\nMetoda mini Reid PN-EN 13016-1:2024-11","categories":["petro","environment"],"row_index":389,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6cb","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej opałowy lekki","methodology":"Zawartość butoksybenzenu (eteru n-butylofenylowego (BPE))","parameters":[{"name":"Zakres","range":"(1,00 – 15,00) mg/l"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrii mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrii mas (GC-MS)"],"computed":[],"activity":"Zawartość butoksybenzenu (eteru n-butylofenylowego (BPE))\nZakres (1,00 – 15,00) mg/l\nMetoda chromatografii gazowej z detekcją spektrometrii mas (GC-MS)","reference":"ILIADe 606:2024 Procedura B","norm_bases":["ILIADe 606:2024 Procedura B"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej opałowy lekki Zawartość butoksybenzenu (eteru n-butylofenylowego (BPE))\nZakres (1,00 – 15,00) mg/l\nMetoda chromatografii gazowej z detekcją spektrometrii mas (GC-MS) ILIADe 606:2024 Procedura B Paliwa ciekle: olej opalowy lekki Zawartosc butoksybenzenu (eteru n-butylofenylowego (BPE))\nZakres (1,00 – 15,00) mg/l\nMetoda chromatografii gazowej z detekcja spektrometrii mas (GC-MS) ILIADe 606:2024 Procedura B","categories":["petro"],"row_index":390,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6cc","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiały smarne: oleje silnikowe, przemysłowe oleje smarowe","methodology":"Lepkość strukturalna w niskich temperaturach","parameters":[{"name":"Zakres","range":"(1300 – 10000) mPa∙s"}],"technique":"Metoda CCS","techniques":["Metoda CCS"],"computed":[],"activity":"Lepkość strukturalna w niskich temperaturach\nZakres (1300 – 10000) mPa∙s\nMetoda CCS","reference":"PN-C-04150:2004 | ASTM D 5293-20","norm_bases":["PN-C-04150:2004","ASTM D 5293-20"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały smarne: oleje silnikowe, przemysłowe oleje smarowe Lepkość strukturalna w niskich temperaturach\nZakres (1300 – 10000) mPa∙s\nMetoda CCS PN-C-04150:2004 | ASTM D 5293-20 Materialy smarne: oleje silnikowe, przemyslowe oleje smarowe Lepkosc strukturalna w niskich temperaturach\nZakres (1300 – 10000) mPa∙s\nMetoda CCS PN-C-04150:2004 | ASTM D 5293-20","categories":["materials","petro"],"row_index":391,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6cd","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiały smarne: oleje silnikowe, przemysłowe oleje smarowe","methodology":"Całkowita liczba zasadowa","parameters":[{"name":"Zakres","range":"(1,0 -90,0) mg/g KOH"}],"technique":"Metoda miareczkowania potencjometrycznego","techniques":["Metoda miareczkowania potencjometrycznego"],"computed":[],"activity":"Całkowita liczba zasadowa\nZakres (1,0 -90,0) mg/g KOH\nMetoda miareczkowania potencjometrycznego","reference":"PN-ISO 3771:2012","norm_bases":["PN-ISO 3771:2012"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały smarne: oleje silnikowe, przemysłowe oleje smarowe Całkowita liczba zasadowa\nZakres (1,0 -90,0) mg/g KOH\nMetoda miareczkowania potencjometrycznego PN-ISO 3771:2012 Materialy smarne: oleje silnikowe, przemyslowe oleje smarowe Calkowita liczba zasadowa\nZakres (1,0 -90,0) mg/g KOH\nMetoda miareczkowania potencjometrycznego PN-ISO 3771:2012","categories":["materials","petro"],"row_index":392,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6ce","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiały smarne: oleje silnikowe, przemysłowe oleje smarowe","methodology":"Temperatura zapłonu","parameters":[{"name":"Zakres","range":"(180 – 270) °C"}],"technique":"Metoda otwartego tygla Clevelanda","techniques":["Metoda otwartego tygla Clevelanda"],"computed":[],"activity":"Temperatura zapłonu\nZakres (180 – 270) °C\nMetoda otwartego tygla Clevelanda","reference":"PN-EN ISO 2592:2017-10 | ASTM D 92-24","norm_bases":["PN-EN ISO 2592:2017-10","ASTM D 92-24"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały smarne: oleje silnikowe, przemysłowe oleje smarowe Temperatura zapłonu\nZakres (180 – 270) °C\nMetoda otwartego tygla Clevelanda PN-EN ISO 2592:2017-10 | ASTM D 92-24 Materialy smarne: oleje silnikowe, przemyslowe oleje smarowe Temperatura zaplonu\nZakres (180 – 270) °C\nMetoda otwartego tygla Clevelanda PN-EN ISO 2592:2017-10 | ASTM D 92-24","categories":["materials","petro"],"row_index":393,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6cf","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiały smarne: oleje silnikowe, przemysłowe oleje smarowe","methodology":"Wskaźnik lepkości (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik lepkości (z obliczeń)","reference":"PN-ISO 2909:2009+Ap1:2010 | ASTM D 2270-24","norm_bases":["PN-ISO 2909:2009+Ap1:2010","ASTM D 2270-24"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały smarne: oleje silnikowe, przemysłowe oleje smarowe Wskaźnik lepkości (z obliczeń) PN-ISO 2909:2009+Ap1:2010 | ASTM D 2270-24 Materialy smarne: oleje silnikowe, przemyslowe oleje smarowe Wskaznik lepkosci (z obliczen) PN-ISO 2909:2009+Ap1:2010 | ASTM D 2270-24","categories":["materials","petro"],"row_index":394,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6d0","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiały smarne: oleje silnikowe, przemysłowe oleje smarowe","methodology":"Własności demulgujące","parameters":[{"name":"Zakres","range":"(5 – 60) min"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Własności demulgujące\nZakres (5 – 60) min\nMetoda wizualna","reference":"PN-ISO 6614:2010+A1:2022-05","norm_bases":["PN-ISO 6614:2010+A1:2022-05"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały smarne: oleje silnikowe, przemysłowe oleje smarowe Własności demulgujące\nZakres (5 – 60) min\nMetoda wizualna PN-ISO 6614:2010+A1:2022-05 Materialy smarne: oleje silnikowe, przemyslowe oleje smarowe Wlasnosci demulgujace\nZakres (5 – 60) min\nMetoda wizualna PN-ISO 6614:2010+A1:2022-05","categories":["materials","petro"],"row_index":395,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6d1","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiały smarne: oleje silnikowe, przemysłowe oleje smarowe","methodology":"Liczba kwasowa","parameters":[{"name":"Zakres","range":"(0,1 – 5,0) mg/g KOH"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Liczba kwasowa\nZakres (0,1 – 5,0) mg/g KOH\nMetoda miareczkowa","reference":"PN-ISO 6618:2011","norm_bases":["PN-ISO 6618:2011"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały smarne: oleje silnikowe, przemysłowe oleje smarowe Liczba kwasowa\nZakres (0,1 – 5,0) mg/g KOH\nMetoda miareczkowa PN-ISO 6618:2011 Materialy smarne: oleje silnikowe, przemyslowe oleje smarowe Liczba kwasowa\nZakres (0,1 – 5,0) mg/g KOH\nMetoda miareczkowa PN-ISO 6618:2011","categories":["materials","petro"],"row_index":396,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6d2","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiały smarne: oleje silnikowe, przemysłowe oleje smarowe","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(0,5 – 8,0)"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Barwa\nZakres (0,5 – 8,0)\nMetoda wizualna","reference":"ASTM D 1500-24","norm_bases":["ASTM D 1500-24"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały smarne: oleje silnikowe, przemysłowe oleje smarowe Barwa\nZakres (0,5 – 8,0)\nMetoda wizualna ASTM D 1500-24 Materialy smarne: oleje silnikowe, przemyslowe oleje smarowe Barwa\nZakres (0,5 – 8,0)\nMetoda wizualna ASTM D 1500-24","categories":["materials","petro"],"row_index":397,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6d3","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiały smarne: oleje silnikowe, przemysłowe oleje smarowe","methodology":"Zawartość wapnia, fosforu, magnezu, cynku","parameters":[{"name":"Ca","range":"(0,003 – 0,300) %m/m"},{"name":"Mg","range":"(0,003 – 0,300) %m/m"},{"name":"P","range":"(0,003 – 0,300) %m/m"},{"name":"Zn","range":"(0,003 – 0,300) %m/m"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość wapnia, fosforu, magnezu, cynku\nZakres:\nCa (0,003 – 0,300) %m/m\nMg (0,003 – 0,300) %m/m\nP (0,003 – 0,300) %m/m\nZn (0,003 – 0,300) %m/m\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"ASTM D 4951-14(2019)","norm_bases":["ASTM D 4951-14(2019)"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały smarne: oleje silnikowe, przemysłowe oleje smarowe Zawartość wapnia, fosforu, magnezu, cynku\nZakres:\nCa (0,003 – 0,300) %m/m\nMg (0,003 – 0,300) %m/m\nP (0,003 – 0,300) %m/m\nZn (0,003 – 0,300) %m/m\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) ASTM D 4951-14(2019) Materialy smarne: oleje silnikowe, przemyslowe oleje smarowe Zawartosc wapnia, fosforu, magnezu, cynku\nZakres:\nCa (0,003 – 0,300) %m/m\nMg (0,003 – 0,300) %m/m\nP (0,003 – 0,300) %m/m\nZn (0,003 – 0,300) %m/m\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) ASTM D 4951-14(2019)","categories":["materials","petro"],"row_index":398,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6d4","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Inne przetwory naftowe: asfalty, wyroby asfaltowe","methodology":"Temperatura łamliwości","parameters":[{"name":"[(-23)","range":"(-8)] °C"}],"technique":"Metoda Fraassa","techniques":["Metoda Fraassa"],"computed":[],"activity":"Temperatura łamliwości\n[(-23) (-8)] °C\nMetoda Fraassa","reference":"PN-EN 12593:2015-08","norm_bases":["PN-EN 12593:2015-08"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Inne przetwory naftowe: asfalty, wyroby asfaltowe Temperatura łamliwości\n[(-23) (-8)] °C\nMetoda Fraassa PN-EN 12593:2015-08 Inne przetwory naftowe: asfalty, wyroby asfaltowe Temperatura lamliwosci\n[(-23) (-8)] °C\nMetoda Fraassa PN-EN 12593:2015-08","categories":["other"],"row_index":399,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6d5","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Inne przetwory naftowe: asfalty, wyroby asfaltowe","methodology":"Penetracja","parameters":[{"name":"Zakres","range":"(20 – 220) * 0,1mm"}],"technique":"Metoda penetracji igłą","techniques":["Metoda penetracji igłą"],"computed":[],"activity":"Penetracja\nZakres (20 – 220) * 0,1mm\nMetoda penetracji igłą","reference":"PN-EN 1426:2025-02","norm_bases":["PN-EN 1426:2025-02"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Inne przetwory naftowe: asfalty, wyroby asfaltowe Penetracja\nZakres (20 – 220) * 0,1mm\nMetoda penetracji igłą PN-EN 1426:2025-02 Inne przetwory naftowe: asfalty, wyroby asfaltowe Penetracja\nZakres (20 – 220) * 0,1mm\nMetoda penetracji igla PN-EN 1426:2025-02","categories":["other"],"row_index":400,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6d6","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Inne przetwory naftowe: asfalty, wyroby asfaltowe","methodology":"Temperatura mięknienia asfaltów","parameters":[{"name":"Zakres","range":"(30,0 – 110,0) °C"}],"technique":"Metoda Pierścień i Kula","techniques":["Metoda Pierścień i Kula"],"computed":[],"activity":"Temperatura mięknienia asfaltów\nZakres (30,0 – 110,0) °C\nMetoda Pierścień i Kula","reference":"PN-EN 1427:2015-08","norm_bases":["PN-EN 1427:2015-08"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Inne przetwory naftowe: asfalty, wyroby asfaltowe Temperatura mięknienia asfaltów\nZakres (30,0 – 110,0) °C\nMetoda Pierścień i Kula PN-EN 1427:2015-08 Inne przetwory naftowe: asfalty, wyroby asfaltowe Temperatura mieknienia asfaltow\nZakres (30,0 – 110,0) °C\nMetoda Pierscien i Kula PN-EN 1427:2015-08","categories":["other"],"row_index":401,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6d7","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Liczba jodowa","parameters":[{"name":"Zakres","range":"(85 – 130) g jodu/100g"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Liczba jodowa\nZakres (85 – 130) g jodu/100g\nMetoda miareczkowa","reference":"PN-EN 14111:2022-11","norm_bases":["PN-EN 14111:2022-11"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Liczba jodowa\nZakres (85 – 130) g jodu/100g\nMetoda miareczkowa PN-EN 14111:2022-11 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Liczba jodowa\nZakres (85 – 130) g jodu/100g\nMetoda miareczkowa PN-EN 14111:2022-11","categories":["petro"],"row_index":402,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6d8","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Liczba kwasowa","parameters":[{"name":"Zakres","range":"(0,10 – 1,00) mg/g KOH"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Liczba kwasowa\nZakres (0,10 – 1,00) mg/g KOH\nMetoda miareczkowa","reference":"PN-EN 14104:2021-06","norm_bases":["PN-EN 14104:2021-06"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Liczba kwasowa\nZakres (0,10 – 1,00) mg/g KOH\nMetoda miareczkowa PN-EN 14104:2021-06 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Liczba kwasowa\nZakres (0,10 – 1,00) mg/g KOH\nMetoda miareczkowa PN-EN 14104:2021-06","categories":["petro"],"row_index":403,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6d9","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Stabilność oksydacyjna","parameters":[{"name":"Zakres","range":"(1,0 – 15,0) h"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Stabilność oksydacyjna\nZakres (1,0 – 15,0) h\nMetoda konduktometryczna","reference":"PN-EN 14112:2021-05","norm_bases":["PN-EN 14112:2021-05"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Stabilność oksydacyjna\nZakres (1,0 – 15,0) h\nMetoda konduktometryczna PN-EN 14112:2021-05 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Stabilnosc oksydacyjna\nZakres (1,0 – 15,0) h\nMetoda konduktometryczna PN-EN 14112:2021-05","categories":["petro"],"row_index":404,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6da","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość estrów metylowych kwasów tłuszczowych (FAME )","parameters":[{"name":"Zakres","range":"(90,0 – 99,0) %(m/m)"},{"name":"Zawartość estru metylowego kwasu linolenowego"},{"name":"Zakres","range":"(1,0 – 15,0) % (m/m)"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość estrów metylowych kwasów tłuszczowych (FAME )\nZakres:\nZakres (90,0 – 99,0) %(m/m)\nZawartość estru metylowego kwasu linolenowego\nZakres (1,0 – 15,0) % (m/m)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 14103:2020-06","norm_bases":["PN-EN 14103:2020-06"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Zawartość estrów metylowych kwasów tłuszczowych (FAME )\nZakres:\nZakres (90,0 – 99,0) %(m/m)\nZawartość estru metylowego kwasu linolenowego\nZakres (1,0 – 15,0) % (m/m)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 14103:2020-06 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Zawartosc estrow metylowych kwasow tluszczowych (FAME )\nZakres:\nZakres (90,0 – 99,0) %(m/m)\nZawartosc estru metylowego kwasu linolenowego\nZakres (1,0 – 15,0) % (m/m)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 14103:2020-06","categories":["petro"],"row_index":405,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6db","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe – estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość wielonienasyconych estrów metylowych kwasów tłuszczowych (powyżej 4 wiązań podwójnych)","parameters":[{"name":"Zakres","range":"(0,6 – 0,8) %(m/m)"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość wielonienasyconych estrów metylowych kwasów tłuszczowych (powyżej 4 wiązań podwójnych)\nZakres (0,6 – 0,8) %(m/m)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 15779+A1:2013-12","norm_bases":["PN-EN 15779+A1:2013-12"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe – estry metylowe kwasów tłuszczowych (FAME) Zawartość wielonienasyconych estrów metylowych kwasów tłuszczowych (powyżej 4 wiązań podwójnych)\nZakres (0,6 – 0,8) %(m/m)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 15779+A1:2013-12 Paliwa ciekle: biopaliwa ciekle – estry metylowe kwasow tluszczowych (FAME) Zawartosc wielonienasyconych estrow metylowych kwasow tluszczowych (powyzej 4 wiazan podwojnych)\nZakres (0,6 – 0,8) %(m/m)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 15779+A1:2013-12","categories":["petro"],"row_index":406,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6dc","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe – estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość monoacylogliceroli","parameters":[{"name":"Zakres","range":"(0,10 – 1,25) %(m/m)"},{"name":"Zawartość diacylogliceroli"},{"name":"Zakres","range":"(0,10 – 0,50) %(m/m)"},{"name":"Zawartość triacylogliceroli"},{"name":"Zakres","range":"(0,10 – 0,40) %(m/m)"},{"name":"Zawartość wolnego glicerolu"},{"name":"Zakres","range":"(0,001 – 0,050) %(m/m)"},{"name":"Zawartość ogólnego glicerolu (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość monoacylogliceroli\nZakres:\nZakres (0,10 – 1,25) %(m/m)\nZawartość diacylogliceroli\nZakres (0,10 – 0,50) %(m/m)\nZawartość triacylogliceroli\nZakres (0,10 – 0,40) %(m/m)\nZawartość wolnego glicerolu\nZakres (0,001 – 0,050) %(m/m)\nZawartość ogólnego glicerolu (z obliczeń)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 14105:2025-04","norm_bases":["PN-EN 14105:2025-04"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe – estry metylowe kwasów tłuszczowych (FAME) Zawartość monoacylogliceroli\nZakres:\nZakres (0,10 – 1,25) %(m/m)\nZawartość diacylogliceroli\nZakres (0,10 – 0,50) %(m/m)\nZawartość triacylogliceroli\nZakres (0,10 – 0,40) %(m/m)\nZawartość wolnego glicerolu\nZakres (0,001 – 0,050) %(m/m)\nZawartość ogólnego glicerolu (z obliczeń)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 14105:2025-04 Paliwa ciekle: biopaliwa ciekle – estry metylowe kwasow tluszczowych (FAME) Zawartosc monoacylogliceroli\nZakres:\nZakres (0,10 – 1,25) %(m/m)\nZawartosc diacylogliceroli\nZakres (0,10 – 0,50) %(m/m)\nZawartosc triacylogliceroli\nZakres (0,10 – 0,40) %(m/m)\nZawartosc wolnego glicerolu\nZakres (0,001 – 0,050) %(m/m)\nZawartosc ogolnego glicerolu (z obliczen)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 14105:2025-04","categories":["petro"],"row_index":407,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6dd","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe – estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość alkoholu metylowego","parameters":[{"name":"Zakres","range":"(0,01 – 0,10) %(m/m)"}],"technique":"Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID)","techniques":["Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID)"],"computed":[],"activity":"Zawartość alkoholu metylowego\nZakres (0,01 – 0,10) %(m/m)\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID)","reference":"PN-EN 14110:2019-05 z wyłączeniem procedury A","norm_bases":["PN-EN 14110:2019-05 z wyłączeniem procedury A"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe – estry metylowe kwasów tłuszczowych (FAME) Zawartość alkoholu metylowego\nZakres (0,01 – 0,10) %(m/m)\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID) PN-EN 14110:2019-05 z wyłączeniem procedury A Paliwa ciekle: biopaliwa ciekle – estry metylowe kwasow tluszczowych (FAME) Zawartosc alkoholu metylowego\nZakres (0,01 – 0,10) %(m/m)\nMetoda chromatografii gazowej z analiza fazy nadpowierzchniowej i detekcja plomieniowo-jonizacyjna (HS-GC-FID) PN-EN 14110:2019-05 z wylaczeniem procedury A","categories":["petro"],"row_index":408,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6de","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe – estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość fosforu","parameters":[{"name":"Zakres","range":"(4,0 – 10,0) mg/kg"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość fosforu\nZakres (4,0 – 10,0) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN 14107:2004","norm_bases":["PN-EN 14107:2004"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe – estry metylowe kwasów tłuszczowych (FAME) Zawartość fosforu\nZakres (4,0 – 10,0) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN 14107:2004 Paliwa ciekle: biopaliwa ciekle – estry metylowe kwasow tluszczowych (FAME) Zawartosc fosforu\nZakres (4,0 – 10,0) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN 14107:2004","categories":["petro"],"row_index":409,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6df","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe – estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość wapnia i magnezu","parameters":[{"name":"Zakres","range":"(1,0 – 10,0) mg/kg"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość wapnia i magnezu\nZakres (1,0 – 10,0) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN 14538:2008","norm_bases":["PN-EN 14538:2008"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe – estry metylowe kwasów tłuszczowych (FAME) Zawartość wapnia i magnezu\nZakres (1,0 – 10,0) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN 14538:2008 Paliwa ciekle: biopaliwa ciekle – estry metylowe kwasow tluszczowych (FAME) Zawartosc wapnia i magnezu\nZakres (1,0 – 10,0) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN 14538:2008","categories":["petro"],"row_index":410,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6e0","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe – estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość sodu","parameters":[{"name":"Zakres","range":"(1,0 – 10,0) mg/kg"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość sodu\nZakres (1,0 – 10,0) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN 14538:2008","norm_bases":["PN-EN 14538:2008"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe – estry metylowe kwasów tłuszczowych (FAME) Zawartość sodu\nZakres (1,0 – 10,0) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN 14538:2008 Paliwa ciekle: biopaliwa ciekle – estry metylowe kwasow tluszczowych (FAME) Zawartosc sodu\nZakres (1,0 – 10,0) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN 14538:2008","categories":["petro"],"row_index":411,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6e1","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe – estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość potasu","parameters":[{"name":"Zakres","range":"(1,0 – 10,0) mg/kg"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość potasu\nZakres (1,0 – 10,0) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN 14538:2008","norm_bases":["PN-EN 14538:2008"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe – estry metylowe kwasów tłuszczowych (FAME) Zawartość potasu\nZakres (1,0 – 10,0) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN 14538:2008 Paliwa ciekle: biopaliwa ciekle – estry metylowe kwasow tluszczowych (FAME) Zawartosc potasu\nZakres (1,0 – 10,0) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN 14538:2008","categories":["petro"],"row_index":412,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6e2","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe – estry metylowe kwasów tłuszczowych (FAME)","methodology":"Skłonność biodiesla do blokowania filtra paliwa","parameters":[{"name":"Zakres","range":"(80 – 400) s"}],"technique":"Metoda CSFT","techniques":["Metoda CSFT"],"computed":[],"activity":"Skłonność biodiesla do blokowania filtra paliwa\nZakres (80 – 400) s\nMetoda CSFT","reference":"ASTM D 7501-22","norm_bases":["ASTM D 7501-22"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe – estry metylowe kwasów tłuszczowych (FAME) Skłonność biodiesla do blokowania filtra paliwa\nZakres (80 – 400) s\nMetoda CSFT ASTM D 7501-22 Paliwa ciekle: biopaliwa ciekle – estry metylowe kwasow tluszczowych (FAME) Sklonnosc biodiesla do blokowania filtra paliwa\nZakres (80 – 400) s\nMetoda CSFT ASTM D 7501-22","categories":["petro"],"row_index":413,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6e3","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":"Metoda manualna","techniques":["Metoda manualna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna PN-ISO 5667-10:2021-11 Scieki Pobieranie probek do badan chemicznych i fizycznych\nMetoda manualna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":414,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6e4","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,005 – 10,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,005 – 10,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie fosforu ogólnego\nZakres (0,005 – 10,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010 Scieki Stezenie fosforu ogolnego\nZakres (0,005 – 10,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":415,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6e5","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(1 – 100) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (1 – 100) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu Kjeldahla\nZakres (1 – 100) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Scieki Stezenie azotu Kjeldahla\nZakres (1 – 100) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":416,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6e6","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu azotanowego","parameters":[{"name":"Zakres","range":"(0,010 – 30,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotanowego\nZakres (0,010 – 30,0) mg/l\nMetoda spektrofotometryczna","reference":"Metoda 125 Wydanie 2 z dnia 16.07.2020","norm_bases":["Metoda 125 Wydanie 2 z dnia 16.07.2020"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu azotanowego\nZakres (0,010 – 30,0) mg/l\nMetoda spektrofotometryczna Metoda 125 Wydanie 2 z dnia 16.07.2020 Scieki Stezenie azotu azotanowego\nZakres (0,010 – 30,0) mg/l\nMetoda spektrofotometryczna Metoda 125 Wydanie 2 z dnia 16.07.2020","categories":["water"],"row_index":417,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6e7","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,005 – 2,5) mg/l"},{"name":"Stężenie azotynów (z obliczeń)"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres:\nZakres (0,005 – 2,5) mg/l\nStężenie azotynów (z obliczeń)\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu azotynowego\nZakres:\nZakres (0,005 – 2,5) mg/l\nStężenie azotynów (z obliczeń)\nMetoda spektrofotometryczna PN-EN 26777:1999 Scieki Stezenie azotu azotynowego\nZakres:\nZakres (0,005 – 2,5) mg/l\nStezenie azotynow (z obliczen)\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":418,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6e8","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu ogólnego (suma azotu Kjeldahla, azotu azotanowego i azotynowego) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu ogólnego (suma azotu Kjeldahla, azotu azotanowego i azotynowego) (z obliczeń)","reference":"Metoda 047 Wydanie 5 z dnia 19.11.2019","norm_bases":["Metoda 047 Wydanie 5 z dnia 19.11.2019"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu ogólnego (suma azotu Kjeldahla, azotu azotanowego i azotynowego) (z obliczeń) Metoda 047 Wydanie 5 z dnia 19.11.2019 Scieki Stezenie azotu ogolnego (suma azotu Kjeldahla, azotu azotanowego i azotynowego) (z obliczen) Metoda 047 Wydanie 5 z dnia 19.11.2019","categories":["water"],"row_index":419,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6e9","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"Chemiczne zapotrzebowanie tlenu","parameters":[{"name":"Zakres","range":"(20,0 – 1000) mg O2/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu\nZakres (20,0 – 1000) mg O2/l\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Chemiczne zapotrzebowanie tlenu\nZakres (20,0 – 1000) mg O2/l\nMetoda spektrofotometryczna PN-ISO 15705:2005 Scieki Chemiczne zapotrzebowanie tlenu\nZakres (20,0 – 1000) mg O2/l\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":420,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6ea","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(5,0 – 50) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (5,0 – 50) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Zawiesiny ogólne\nZakres (5,0 – 50) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Scieki, woda Zawiesiny ogolne\nZakres (5,0 – 50) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":421,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6eb","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: wodór (automotive)","methodology":"Oznaczanie zawartości wody","parameters":[{"name":"Zakres","range":"(1,00 -10,00) μmol/mol"}],"technique":"Metoda spektrometrii strat we wnęce optycznej z falą ciągłą (CRDS)","techniques":["Metoda spektrometrii strat we wnęce optycznej z falą ciągłą (CRDS)"],"computed":[],"activity":"Oznaczanie zawartości wody\nZakres (1,00 -10,00) μmol/mol\nMetoda spektrometrii strat we wnęce optycznej z falą ciągłą (CRDS)","reference":"NPL Report AS64:2011-08 p. 4.2.1 (a) | Instrukcja IT-M/PP6/95 wydanie 2 z dnia 11.03.2024","norm_bases":["NPL Report AS64:2011-08 p. 4.2.1 (a)","Instrukcja IT-M/PP6/95 wydanie 2 z dnia 11.03.2024"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: wodór (automotive) Oznaczanie zawartości wody\nZakres (1,00 -10,00) μmol/mol\nMetoda spektrometrii strat we wnęce optycznej z falą ciągłą (CRDS) NPL Report AS64:2011-08 p. 4.2.1 (a) | Instrukcja IT-M/PP6/95 wydanie 2 z dnia 11.03.2024 Paliwa gazowe: wodor (automotive) Oznaczanie zawartosci wody\nZakres (1,00 -10,00) μmol/mol\nMetoda spektrometrii strat we wnece optycznej z fala ciagla (CRDS) NPL Report AS64:2011-08 p. 4.2.1 (a) | Instrukcja IT-M/PP6/95 wydanie 2 z dnia 11.03.2024","categories":["water","petro","automotive"],"row_index":422,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6ec","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: wodór (automotive)","methodology":"Zawartość siarkowodoru, siarczku karbonylu, merkaptanu metylowego, disiarczuk węgla","parameters":[{"name":"Siarkowodór","range":"(0,003 – 0,010) μmol/mol"},{"name":"Siarczek karbonylu","range":"(0,003 – 0,010)"},{"name":"μmol/mol Merkaptan metylowy","range":"(0,003 – 0,010)"},{"name":"μmol/mol Disiarczek węgla","range":"(0,003 – 0,010)"},{"name":"Związki siarki ogółem (z obliczeń)"}],"technique":"Metodą chromatografii gazowej z detektorem chemiluminescencyjnym (GC-SCD)","techniques":["Metodą chromatografii gazowej z detektorem chemiluminescencyjnym (GC-SCD)"],"computed":[],"activity":"Zawartość siarkowodoru, siarczku karbonylu, merkaptanu metylowego, disiarczuk węgla\nZakres:\nSiarkowodór (0,003 – 0,010) μmol/mol\nSiarczek karbonylu (0,003 – 0,010)\nμmol/mol Merkaptan metylowy (0,003 – 0,010)\nμmol/mol Disiarczek węgla (0,003 – 0,010)\nZwiązki siarki ogółem (z obliczeń)\nMetodą chromatografii gazowej z detektorem chemiluminescencyjnym (GC-SCD)","reference":"ASTM D 7652-11","norm_bases":["ASTM D 7652-11"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: wodór (automotive) Zawartość siarkowodoru, siarczku karbonylu, merkaptanu metylowego, disiarczuk węgla\nZakres:\nSiarkowodór (0,003 – 0,010) μmol/mol\nSiarczek karbonylu (0,003 – 0,010)\nμmol/mol Merkaptan metylowy (0,003 – 0,010)\nμmol/mol Disiarczek węgla (0,003 – 0,010)\nZwiązki siarki ogółem (z obliczeń)\nMetodą chromatografii gazowej z detektorem chemiluminescencyjnym (GC-SCD) ASTM D 7652-11 Paliwa gazowe: wodor (automotive) Zawartosc siarkowodoru, siarczku karbonylu, merkaptanu metylowego, disiarczuk wegla\nZakres:\nSiarkowodor (0,003 – 0,010) μmol/mol\nSiarczek karbonylu (0,003 – 0,010)\nμmol/mol Merkaptan metylowy (0,003 – 0,010)\nμmol/mol Disiarczek wegla (0,003 – 0,010)\nZwiazki siarki ogolem (z obliczen)\nMetoda chromatografii gazowej z detektorem chemiluminescencyjnym (GC-SCD) ASTM D 7652-11","categories":["petro","automotive"],"row_index":423,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6ed","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: wodór (automotive)","methodology":"Zawartość helu","parameters":[{"name":"Hel","range":"(75,0 – 315,0) μmol/mol"},{"name":"Zawartość ditlenku węgla, tlenku węgla, metanu i węglowodorów ogółem z wyłączeniem metanu","range":"(ekwiwalent C1)"},{"name":"Ditlenek węgla","range":"(0,5 – 2,0) μmol/mol"},{"name":"Tlenek węgla","range":"(0,055 – 0,220) μmol/mol"},{"name":"Metan","range":"(30,0 – 100,0) μmol/mol"},{"name":"Węglowodory ogółem z wyłączeniem metanu (ekwiwalent C1)","range":"(0,5 – 2,0)"},{"name":"μmol/mol"}],"technique":"Metoda chromatografii gazowej z detektorem termokonduktometrycznym (GC-TCD); Metoda chromatografii gazowej z detektorem płomieniowo – jonizacyjnym i termokonduktometrycznym (GC-FID/TCD)","techniques":["Metoda chromatografii gazowej z detektorem termokonduktometrycznym (GC-TCD)","Metoda chromatografii gazowej z detektorem płomieniowo – jonizacyjnym i termokonduktometrycznym (GC-FID/TCD)"],"computed":[],"activity":"Zawartość helu\nZakres:\nHel (75,0 – 315,0) μmol/mol\nZawartość ditlenku węgla, tlenku węgla, metanu i węglowodorów ogółem z wyłączeniem metanu (ekwiwalent C1)\nDitlenek węgla (0,5 – 2,0) μmol/mol\nTlenek węgla (0,055 – 0,220) μmol/mol\nMetan (30,0 – 100,0) μmol/mol\nWęglowodory ogółem z wyłączeniem metanu (ekwiwalent C1) (0,5 – 2,0)\nμmol/mol\nMetoda chromatografii gazowej z detektorem termokonduktometrycznym (GC-TCD); Metoda chromatografii gazowej z detektorem płomieniowo – jonizacyjnym i termokonduktometrycznym (GC-FID/TCD)","reference":"NPL Report AS64:2011-08 p.4.2.4 (a) | Instrukcja IT-M/PP6/97 wydanie 3 z dnia 25.03.2024 NPL Report AS64:2011-08 p. 4.2.7 (a), p. 4.2.8 (b), p. 4.2.2 (a) | Instrukcja IT-M/PP6/97 wydanie 3 z dnia 25.03.2024","norm_bases":["NPL Report AS64:2011-08 p.4.2.4 (a)","Instrukcja IT-M/PP6/97 wydanie 3 z dnia 25.03.2024 NPL Report AS64:2011-08 p. 4.2.7 (a), p. 4.2.8 (b), p. 4.2.2 (a)","Instrukcja IT-M/PP6/97 wydanie 3 z dnia 25.03.2024"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: wodór (automotive) Zawartość helu\nZakres:\nHel (75,0 – 315,0) μmol/mol\nZawartość ditlenku węgla, tlenku węgla, metanu i węglowodorów ogółem z wyłączeniem metanu (ekwiwalent C1)\nDitlenek węgla (0,5 – 2,0) μmol/mol\nTlenek węgla (0,055 – 0,220) μmol/mol\nMetan (30,0 – 100,0) μmol/mol\nWęglowodory ogółem z wyłączeniem metanu (ekwiwalent C1) (0,5 – 2,0)\nμmol/mol\nMetoda chromatografii gazowej z detektorem termokonduktometrycznym (GC-TCD); Metoda chromatografii gazowej z detektorem płomieniowo – jonizacyjnym i termokonduktometrycznym (GC-FID/TCD) NPL Report AS64:2011-08 p.4.2.4 (a) | Instrukcja IT-M/PP6/97 wydanie 3 z dnia 25.03.2024 NPL Report AS64:2011-08 p. 4.2.7 (a), p. 4.2.8 (b), p. 4.2.2 (a) | Instrukcja IT-M/PP6/97 wydanie 3 z dnia 25.03.2024 Paliwa gazowe: wodor (automotive) Zawartosc helu\nZakres:\nHel (75,0 – 315,0) μmol/mol\nZawartosc ditlenku wegla, tlenku wegla, metanu i weglowodorow ogolem z wylaczeniem metanu (ekwiwalent C1)\nDitlenek wegla (0,5 – 2,0) μmol/mol\nTlenek wegla (0,055 – 0,220) μmol/mol\nMetan (30,0 – 100,0) μmol/mol\nWeglowodory ogolem z wylaczeniem metanu (ekwiwalent C1) (0,5 – 2,0)\nμmol/mol\nMetoda chromatografii gazowej z detektorem termokonduktometrycznym (GC-TCD); Metoda chromatografii gazowej z detektorem plomieniowo – jonizacyjnym i termokonduktometrycznym (GC-FID/TCD) NPL Report AS64:2011-08 p.4.2.4 (a) | Instrukcja IT-M/PP6/97 wydanie 3 z dnia 25.03.2024 NPL Report AS64:2011-08 p. 4.2.7 (a), p. 4.2.8 (b), p. 4.2.2 (a) | Instrukcja IT-M/PP6/97 wydanie 3 z dnia 25.03.2024","categories":["petro","automotive"],"row_index":424,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6ee","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: wodór (automotive)","methodology":"Zawartość formaldehydu i halogenków organicznych","parameters":[{"name":"Formaldehyd","range":"(0,05 – 0,40) μmol/mol"},{"name":"Związki halogenowe organiczne:"},{"name":"Zakres","range":"1,2,4-trichlorobenzen (0,002 – 0,04)"},{"name":"μmol/mol 1,2-dichlorobenzen","range":"(0,002 – 0,04)"},{"name":"μmol/mol 1,3-dichlorobenzen","range":"(0,002 – 0,04)"},{"name":"μmol/mol 1,1,2,2-tetrachloroetan","range":"(0,002 - 0,04)"},{"name":"μmol/mol chlorobenzen","range":"(0,002 – 0,04) μmol/mol"},{"name":"tetrachloroetylen","range":"(0,002 – 0,04) μmol/mol"},{"name":"1,2-dibromoetan","range":"(0,002 – 0,04) μmol/mol"},{"name":"1,1,2-trichloroetan","range":"(0,002 – 0,04) μmol/mol"},{"name":"trans-1,3-dichloropropen","range":"(0,002 – 0,04)"},{"name":"μmol/mol 1,3-dichloropropen","range":"(0,002 – 0,04) μmol/mol"},{"name":"trichloroetylen","range":"( 0,002 – 0,04) μmol/mol"},{"name":"1,2-dichloropropan","range":"(0,002 – 0,04) μmol/mol"},{"name":"tetrachlorek węgla","range":"(0,002 – 0,04) μmol/mol"},{"name":"1,1,1-trichloroetan","range":"(0,002 – 0,04) μmol/mol"},{"name":"1,2-dichloroetan","range":"(0,002 – 0,04) μmol/mol"},{"name":"trichlorometan","range":"(0,002 – 0,04) μmol/mol"},{"name":"cis-1,1-dichloroeten","range":"(0,002 – 0,04)"},{"name":"μmol/mol 1,1-dichloroetan","range":"(0,002 – 0,04) μmol/mol"},{"name":"1,1,2-trichloro-1,2,2-trifluorometan","range":"(0,002 – 0,04) μmol/mol"},{"name":"chlorek allilu","range":"(0,002 – 0,04) μmol/mol"},{"name":"chlorek metylenu","range":"(0,002 – 0,04) μmol/mol"},{"name":"1,1-dichloroetan","range":"(0,002 – 0,04) μmol/mol"},{"name":"trichloromonofluorometan","range":"(0,002 – 0,04)"},{"name":"μmol/mol chlorek etylu","range":"(0,002 – 0,04) μmol/mol"},{"name":"bromometan","range":"(0,002 – 0,04) μmol/mol"},{"name":"chloroeten","range":"(0,002 – 0,04) μmol/mol"},{"name":"1,2-dichloro-1,1,1,2-tetrafluoroetan","range":"(0,002 – 0,04) μmol/mol"},{"name":"chlorometan","range":"(0,002 – 0,04) μmol/mol"},{"name":"dichlorodifluorometan","range":"(0,002 – 0,04)"},{"name":"μmol/mol Zawartość związków halogenowych organicznych (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas mas (GC-MS)"],"computed":[],"activity":"Zawartość formaldehydu i halogenków organicznych\nZakres:\nFormaldehyd (0,05 – 0,40) μmol/mol\nZwiązki halogenowe organiczne:\nZakres 1,2,4-trichlorobenzen (0,002 – 0,04)\nμmol/mol 1,2-dichlorobenzen (0,002 – 0,04)\nμmol/mol 1,3-dichlorobenzen (0,002 – 0,04)\nμmol/mol 1,1,2,2-tetrachloroetan (0,002 - 0,04)\nμmol/mol chlorobenzen (0,002 – 0,04) μmol/mol\ntetrachloroetylen (0,002 – 0,04) μmol/mol\n1,2-dibromoetan (0,002 – 0,04) μmol/mol\n1,1,2-trichloroetan (0,002 – 0,04) μmol/mol\ntrans-1,3-dichloropropen (0,002 – 0,04)\nμmol/mol 1,3-dichloropropen (0,002 – 0,04) μmol/mol\ntrichloroetylen ( 0,002 – 0,04) μmol/mol\n1,2-dichloropropan (0,002 – 0,04) μmol/mol\ntetrachlorek węgla (0,002 – 0,04) μmol/mol\n1,1,1-trichloroetan (0,002 – 0,04) μmol/mol\n1,2-dichloroetan (0,002 – 0,04) μmol/mol\ntrichlorometan (0,002 – 0,04) μmol/mol\ncis-1,1-dichloroeten (0,002 – 0,04)\nμmol/mol 1,1-dichloroetan (0,002 – 0,04) μmol/mol\n1,1,2-trichloro-1,2,2-trifluorometan (0,002 – 0,04) μmol/mol\nchlorek allilu (0,002 – 0,04) μmol/mol\nchlorek metylenu (0,002 – 0,04) μmol/mol\n1,1-dichloroetan (0,002 – 0,04) μmol/mol\ntrichloromonofluorometan (0,002 – 0,04)\nμmol/mol chlorek etylu (0,002 – 0,04) μmol/mol\nbromometan (0,002 – 0,04) μmol/mol\nchloroeten (0,002 – 0,04) μmol/mol\n1,2-dichloro-1,1,1,2-tetrafluoroetan (0,002 – 0,04) μmol/mol\nchlorometan (0,002 – 0,04) μmol/mol\ndichlorodifluorometan (0,002 – 0,04)\nμmol/mol Zawartość związków halogenowych organicznych (z obliczeń)\nMetoda chromatografii gazowej z detekcją spektrometrią mas mas (GC-MS)","reference":"ASTM D 7892-25","norm_bases":["ASTM D 7892-25"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: wodór (automotive) Zawartość formaldehydu i halogenków organicznych\nZakres:\nFormaldehyd (0,05 – 0,40) μmol/mol\nZwiązki halogenowe organiczne:\nZakres 1,2,4-trichlorobenzen (0,002 – 0,04)\nμmol/mol 1,2-dichlorobenzen (0,002 – 0,04)\nμmol/mol 1,3-dichlorobenzen (0,002 – 0,04)\nμmol/mol 1,1,2,2-tetrachloroetan (0,002 - 0,04)\nμmol/mol chlorobenzen (0,002 – 0,04) μmol/mol\ntetrachloroetylen (0,002 – 0,04) μmol/mol\n1,2-dibromoetan (0,002 – 0,04) μmol/mol\n1,1,2-trichloroetan (0,002 – 0,04) μmol/mol\ntrans-1,3-dichloropropen (0,002 – 0,04)\nμmol/mol 1,3-dichloropropen (0,002 – 0,04) μmol/mol\ntrichloroetylen ( 0,002 – 0,04) μmol/mol\n1,2-dichloropropan (0,002 – 0,04) μmol/mol\ntetrachlorek węgla (0,002 – 0,04) μmol/mol\n1,1,1-trichloroetan (0,002 – 0,04) μmol/mol\n1,2-dichloroetan (0,002 – 0,04) μmol/mol\ntrichlorometan (0,002 – 0,04) μmol/mol\ncis-1,1-dichloroeten (0,002 – 0,04)\nμmol/mol 1,1-dichloroetan (0,002 – 0,04) μmol/mol\n1,1,2-trichloro-1,2,2-trifluorometan (0,002 – 0,04) μmol/mol\nchlorek allilu (0,002 – 0,04) μmol/mol\nchlorek metylenu (0,002 – 0,04) μmol/mol\n1,1-dichloroetan (0,002 – 0,04) μmol/mol\ntrichloromonofluorometan (0,002 – 0,04)\nμmol/mol chlorek etylu (0,002 – 0,04) μmol/mol\nbromometan (0,002 – 0,04) μmol/mol\nchloroeten (0,002 – 0,04) μmol/mol\n1,2-dichloro-1,1,1,2-tetrafluoroetan (0,002 – 0,04) μmol/mol\nchlorometan (0,002 – 0,04) μmol/mol\ndichlorodifluorometan (0,002 – 0,04)\nμmol/mol Zawartość związków halogenowych organicznych (z obliczeń)\nMetoda chromatografii gazowej z detekcją spektrometrią mas mas (GC-MS) ASTM D 7892-25 Paliwa gazowe: wodor (automotive) Zawartosc formaldehydu i halogenkow organicznych\nZakres:\nFormaldehyd (0,05 – 0,40) μmol/mol\nZwiazki halogenowe organiczne:\nZakres 1,2,4-trichlorobenzen (0,002 – 0,04)\nμmol/mol 1,2-dichlorobenzen (0,002 – 0,04)\nμmol/mol 1,3-dichlorobenzen (0,002 – 0,04)\nμmol/mol 1,1,2,2-tetrachloroetan (0,002 - 0,04)\nμmol/mol chlorobenzen (0,002 – 0,04) μmol/mol\ntetrachloroetylen (0,002 – 0,04) μmol/mol\n1,2-dibromoetan (0,002 – 0,04) μmol/mol\n1,1,2-trichloroetan (0,002 – 0,04) μmol/mol\ntrans-1,3-dichloropropen (0,002 – 0,04)\nμmol/mol 1,3-dichloropropen (0,002 – 0,04) μmol/mol\ntrichloroetylen ( 0,002 – 0,04) μmol/mol\n1,2-dichloropropan (0,002 – 0,04) μmol/mol\ntetrachlorek wegla (0,002 – 0,04) μmol/mol\n1,1,1-trichloroetan (0,002 – 0,04) μmol/mol\n1,2-dichloroetan (0,002 – 0,04) μmol/mol\ntrichlorometan (0,002 – 0,04) μmol/mol\ncis-1,1-dichloroeten (0,002 – 0,04)\nμmol/mol 1,1-dichloroetan (0,002 – 0,04) μmol/mol\n1,1,2-trichloro-1,2,2-trifluorometan (0,002 – 0,04) μmol/mol\nchlorek allilu (0,002 – 0,04) μmol/mol\nchlorek metylenu (0,002 – 0,04) μmol/mol\n1,1-dichloroetan (0,002 – 0,04) μmol/mol\ntrichloromonofluorometan (0,002 – 0,04)\nμmol/mol chlorek etylu (0,002 – 0,04) μmol/mol\nbromometan (0,002 – 0,04) μmol/mol\nchloroeten (0,002 – 0,04) μmol/mol\n1,2-dichloro-1,1,1,2-tetrafluoroetan (0,002 – 0,04) μmol/mol\nchlorometan (0,002 – 0,04) μmol/mol\ndichlorodifluorometan (0,002 – 0,04)\nμmol/mol Zawartosc zwiazkow halogenowych organicznych (z obliczen)\nMetoda chromatografii gazowej z detekcja spektrometria mas mas (GC-MS) ASTM D 7892-25","categories":["petro","automotive"],"row_index":425,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6ef","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: wodór (automotive)","methodology":"Zawartość argonu, azotu, tlenu","parameters":[{"name":"Argon","range":"(4,0 – 300,0) μmol/mol"},{"name":"Azot","range":"(5,0 – 300,0)μmol/mol"},{"name":"Tlen","range":"(2,0 – 10,0) μmol/mol"}],"technique":"Metoda chromatografii gazowej z detektorem wyładowań helowych (GC-PDHID)","techniques":["Metoda chromatografii gazowej z detektorem wyładowań helowych (GC-PDHID)"],"computed":[],"activity":"Zawartość argonu, azotu, tlenu\nZakres:\nArgon (4,0 – 300,0) μmol/mol\nAzot (5,0 – 300,0)μmol/mol\nTlen (2,0 – 10,0) μmol/mol\nMetoda chromatografii gazowej z detektorem wyładowań helowych (GC-PDHID)","reference":"NPL Report AS64:2011-08 p. 4.2.6 (b), p. 4.2.5 (a), p. 4.2.3 (a) | Instrukcja IT-M/PP6/98 wydanie 3 z dnia 25.03.2024","norm_bases":["NPL Report AS64:2011-08 p. 4.2.6 (b), p. 4.2.5 (a), p. 4.2.3 (a)","Instrukcja IT-M/PP6/98 wydanie 3 z dnia 25.03.2024"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: wodór (automotive) Zawartość argonu, azotu, tlenu\nZakres:\nArgon (4,0 – 300,0) μmol/mol\nAzot (5,0 – 300,0)μmol/mol\nTlen (2,0 – 10,0) μmol/mol\nMetoda chromatografii gazowej z detektorem wyładowań helowych (GC-PDHID) NPL Report AS64:2011-08 p. 4.2.6 (b), p. 4.2.5 (a), p. 4.2.3 (a) | Instrukcja IT-M/PP6/98 wydanie 3 z dnia 25.03.2024 Paliwa gazowe: wodor (automotive) Zawartosc argonu, azotu, tlenu\nZakres:\nArgon (4,0 – 300,0) μmol/mol\nAzot (5,0 – 300,0)μmol/mol\nTlen (2,0 – 10,0) μmol/mol\nMetoda chromatografii gazowej z detektorem wyladowan helowych (GC-PDHID) NPL Report AS64:2011-08 p. 4.2.6 (b), p. 4.2.5 (a), p. 4.2.3 (a) | Instrukcja IT-M/PP6/98 wydanie 3 z dnia 25.03.2024","categories":["petro","automotive"],"row_index":426,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6f0","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: wodór (automotive)","methodology":"Zawartość kwasu mrówkowego, amoniaku","parameters":[{"name":"Kwas mrówkowy","range":"(0,05 – 0,40) μmol/mol"},{"name":"Amoniak","range":"(0,05 – 0,40) μmol/mol"}],"technique":"Metoda chromatografii jonowej z detektorem konduktometrycznym (IC)","techniques":["Metoda chromatografii jonowej z detektorem konduktometrycznym (IC)"],"computed":[],"activity":"Zawartość kwasu mrówkowego, amoniaku\nZakres:\nKwas mrówkowy (0,05 – 0,40) μmol/mol\nAmoniak (0,05 – 0,40) μmol/mol\nMetoda chromatografii jonowej z detektorem konduktometrycznym (IC)","reference":"JIS K0127:2013 | Instrukcja IT-M/PP6/96 wydanie 2 z dnia 11.03.2024","norm_bases":["JIS K0127:2013","Instrukcja IT-M/PP6/96 wydanie 2 z dnia 11.03.2024"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: wodór (automotive) Zawartość kwasu mrówkowego, amoniaku\nZakres:\nKwas mrówkowy (0,05 – 0,40) μmol/mol\nAmoniak (0,05 – 0,40) μmol/mol\nMetoda chromatografii jonowej z detektorem konduktometrycznym (IC) JIS K0127:2013 | Instrukcja IT-M/PP6/96 wydanie 2 z dnia 11.03.2024 Paliwa gazowe: wodor (automotive) Zawartosc kwasu mrowkowego, amoniaku\nZakres:\nKwas mrowkowy (0,05 – 0,40) μmol/mol\nAmoniak (0,05 – 0,40) μmol/mol\nMetoda chromatografii jonowej z detektorem konduktometrycznym (IC) JIS K0127:2013 | Instrukcja IT-M/PP6/96 wydanie 2 z dnia 11.03.2024","categories":["petro","automotive"],"row_index":427,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6f1","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: wodór (automotive)","methodology":"Zawartość cząstek stałych","parameters":[{"name":"Zakres","range":"(0,15 – 1,40) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość cząstek stałych\nZakres (0,15 – 1,40) mg/kg\nMetoda wagowa","reference":"ASTM D 7651:24e1","norm_bases":["ASTM D 7651:24e1"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: wodór (automotive) Zawartość cząstek stałych\nZakres (0,15 – 1,40) mg/kg\nMetoda wagowa ASTM D 7651:24e1 Paliwa gazowe: wodor (automotive) Zawartosc czastek stalych\nZakres (0,15 – 1,40) mg/kg\nMetoda wagowa ASTM D 7651:24e1","categories":["petro","automotive"],"row_index":428,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6f2","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: wodór (automotive)","methodology":"Indeks paliwa wodorowego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Indeks paliwa wodorowego (z obliczeń)","reference":"ISO 14687:2019-11","norm_bases":["ISO 14687:2019-11"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: wodór (automotive) Indeks paliwa wodorowego (z obliczeń) ISO 14687:2019-11 Paliwa gazowe: wodor (automotive) Indeks paliwa wodorowego (z obliczen) ISO 14687:2019-11","categories":["petro","automotive"],"row_index":429,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6f3","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: wodór (automotive)","methodology":"Całkowita zawartość gazów innych niż wodór (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Całkowita zawartość gazów innych niż wodór (z obliczeń)","reference":"ISO 14687:2019-11","norm_bases":["ISO 14687:2019-11"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: wodór (automotive) Całkowita zawartość gazów innych niż wodór (z obliczeń) ISO 14687:2019-11 Paliwa gazowe: wodor (automotive) Calkowita zawartosc gazow innych niz wodor (z obliczen) ISO 14687:2019-11","categories":["petro","automotive"],"row_index":430,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6f4","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy","methodology":"Pobieranie próbek z dystrybutora do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek z dystrybutora do badań chemicznych i fizycznych","reference":"PN-EN 14275:2013-06","norm_bases":["PN-EN 14275:2013-06"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy Pobieranie próbek z dystrybutora do badań chemicznych i fizycznych PN-EN 14275:2013-06 Paliwa ciekle: benzyna bezolowiowa, olej napedowy Pobieranie probek z dystrybutora do badan chemicznych i fizycznych PN-EN 14275:2013-06","categories":["petro"],"row_index":431,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6f5","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej opałowy lekki, olej opałowy ciężki, benzyna bezołowiowa, olej napędowy, Materiały smarne: oleje bazowe, oleje silnikowe, przemysłowe oleje smarowe, Ropa naftowa","methodology":"Pobieranie próbek ze zbiorników do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek ze zbiorników do badań chemicznych i fizycznych","reference":"PN-EN ISO 3170:2025-12 z wyłączeniem 8.3.1.3 - 8.3.1.6, 8.3.1.8, 8.3.2, 8.7, 8.8, 9.8, 10.6, 10.7","norm_bases":["PN-EN ISO 3170:2025-12 z wyłączeniem 8.3.1.3 - 8.3.1.6, 8.3.1.8, 8.3.2, 8.7, 8.8, 9.8, 10.6, 10.7"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej opałowy lekki, olej opałowy ciężki, benzyna bezołowiowa, olej napędowy, Materiały smarne: oleje bazowe, oleje silnikowe, przemysłowe oleje smarowe, Ropa naftowa Pobieranie próbek ze zbiorników do badań chemicznych i fizycznych PN-EN ISO 3170:2025-12 z wyłączeniem 8.3.1.3 - 8.3.1.6, 8.3.1.8, 8.3.2, 8.7, 8.8, 9.8, 10.6, 10.7 Paliwa ciekle: olej opalowy lekki, olej opalowy ciezki, benzyna bezolowiowa, olej napedowy, Materialy smarne: oleje bazowe, oleje silnikowe, przemyslowe oleje smarowe, Ropa naftowa Pobieranie probek ze zbiornikow do badan chemicznych i fizycznych PN-EN ISO 3170:2025-12 z wylaczeniem 8.3.1.3 - 8.3.1.6, 8.3.1.8, 8.3.2, 8.7, 8.8, 9.8, 10.6, 10.7","categories":["petro","materials"],"row_index":432,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6f6","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Liczba oktanowa LOM","parameters":[{"name":"Zakres","range":"60 – 100"}],"technique":"Metoda silnikowa","techniques":["Metoda silnikowa"],"computed":[],"activity":"Liczba oktanowa LOM\nZakres 60 – 100\nMetoda silnikowa","reference":"PN-EN ISO 5163:2014-08","norm_bases":["PN-EN ISO 5163:2014-08"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Liczba oktanowa LOM\nZakres 60 – 100\nMetoda silnikowa PN-EN ISO 5163:2014-08 Paliwa ciekle: benzyna bezolowiowa Liczba oktanowa LOM\nZakres 60 – 100\nMetoda silnikowa PN-EN ISO 5163:2014-08","categories":["petro"],"row_index":433,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6f7","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Indeks lotności (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Indeks lotności (z obliczeń)","reference":"PN-EN 228+A1:2017-06 p. 5.5.2","norm_bases":["PN-EN 228+A1:2017-06 p. 5.5.2"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Indeks lotności (z obliczeń) PN-EN 228+A1:2017-06 p. 5.5.2 Paliwa ciekle: benzyna bezolowiowa Indeks lotnosci (z obliczen) PN-EN 228+A1:2017-06 p. 5.5.2","categories":["petro"],"row_index":434,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6f8","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Prężność par nasyconych powietrzem","parameters":[{"name":"Zakres","range":"(40,0 – 106,0) kPa"}],"technique":"Metoda mini Reid","techniques":["Metoda mini Reid"],"computed":[],"activity":"Prężność par nasyconych powietrzem\nZakres (40,0 – 106,0) kPa\nMetoda mini Reid","reference":"PN-EN 13016-1:2024-11","norm_bases":["PN-EN 13016-1:2024-11"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Prężność par nasyconych powietrzem\nZakres (40,0 – 106,0) kPa\nMetoda mini Reid PN-EN 13016-1:2024-11 Paliwa ciekle: benzyna bezolowiowa Preznosc par nasyconych powietrzem\nZakres (40,0 – 106,0) kPa\nMetoda mini Reid PN-EN 13016-1:2024-11","categories":["petro","environment"],"row_index":435,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6f9","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Zawartość tlenowych związków organicznych","parameters":[{"name":"Zakres","range":"(0,17 – 15,0) % (v/v)"},{"name":"Całkowita zawartość organicznie związanego tlenu (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość tlenowych związków organicznych\nZakres:\nZakres (0,17 – 15,0) % (v/v)\nCałkowita zawartość organicznie związanego tlenu (z obliczeń)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13132:2005","norm_bases":["PN-EN 13132:2005"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Zawartość tlenowych związków organicznych\nZakres:\nZakres (0,17 – 15,0) % (v/v)\nCałkowita zawartość organicznie związanego tlenu (z obliczeń)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13132:2005 Paliwa ciekle: benzyna bezolowiowa Zawartosc tlenowych zwiazkow organicznych\nZakres:\nZakres (0,17 – 15,0) % (v/v)\nCalkowita zawartosc organicznie zwiazanego tlenu (z obliczen)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13132:2005","categories":["petro"],"row_index":436,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6fa","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki, Wyroby chemiczne: rozpuszczalniki","methodology":"Gęstość","parameters":[{"name":"Zakres","range":"(650,0 – 950,0) kg/m3"}],"technique":"Metoda areometryczna","techniques":["Metoda areometryczna"],"computed":[],"activity":"Gęstość\nZakres (650,0 – 950,0) kg/m3\nMetoda areometryczna","reference":"PN-EN ISO 3675:2004","norm_bases":["PN-EN ISO 3675:2004"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki, Wyroby chemiczne: rozpuszczalniki Gęstość\nZakres (650,0 – 950,0) kg/m3\nMetoda areometryczna PN-EN ISO 3675:2004 Paliwa ciekle: benzyna bezolowiowa, olej napedowy, olej opalowy lekki, Wyroby chemiczne: rozpuszczalniki Gestosc\nZakres (650,0 – 950,0) kg/m3\nMetoda areometryczna PN-EN ISO 3675:2004","categories":["petro"],"row_index":437,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6fb","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki, Wyroby chemiczne: rozpuszczalniki","methodology":"Gęstość w temperaturze 15°C","parameters":[{"name":"Zakres","range":"(664,0 – 900,0) kg/m3"}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"computed":[],"activity":"Gęstość w temperaturze 15°C\nZakres (664,0 – 900,0) kg/m3\nMetoda oscylacyjna","reference":"PN-EN ISO 12185:2024-08","norm_bases":["PN-EN ISO 12185:2024-08"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki, Wyroby chemiczne: rozpuszczalniki Gęstość w temperaturze 15°C\nZakres (664,0 – 900,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08 Paliwa ciekle: benzyna bezolowiowa, olej napedowy, olej opalowy lekki, Wyroby chemiczne: rozpuszczalniki Gestosc w temperaturze 15°C\nZakres (664,0 – 900,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08","categories":["petro"],"row_index":438,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6fc","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki, Wyroby chemiczne: rozpuszczalniki","methodology":"Skład frakcyjny","parameters":[{"name":"Zakres","range":"(10,0 – 370,0) °C"}],"technique":"Metoda destylacyjna","techniques":["Metoda destylacyjna"],"computed":[],"activity":"Skład frakcyjny\nZakres (10,0 – 370,0) °C\nMetoda destylacyjna","reference":"PN-EN ISO 3405:2019-05","norm_bases":["PN-EN ISO 3405:2019-05"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki, Wyroby chemiczne: rozpuszczalniki Skład frakcyjny\nZakres (10,0 – 370,0) °C\nMetoda destylacyjna PN-EN ISO 3405:2019-05 Paliwa ciekle: benzyna bezolowiowa, olej napedowy, olej opalowy lekki, Wyroby chemiczne: rozpuszczalniki Sklad frakcyjny\nZakres (10,0 – 370,0) °C\nMetoda destylacyjna PN-EN ISO 3405:2019-05","categories":["petro"],"row_index":439,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6fd","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki, Wyroby chemiczne: rozpuszczalniki","methodology":"Działanie korodujące na miedź","parameters":[{"name":"Zakres","range":"1a – 4c (skala)"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Działanie korodujące na miedź\nZakres 1a – 4c (skala)\nMetoda wizualna","reference":"PN-EN ISO 2160:2004","norm_bases":["PN-EN ISO 2160:2004"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki, Wyroby chemiczne: rozpuszczalniki Działanie korodujące na miedź\nZakres 1a – 4c (skala)\nMetoda wizualna PN-EN ISO 2160:2004 Paliwa ciekle: benzyna bezolowiowa, olej napedowy, olej opalowy lekki, Wyroby chemiczne: rozpuszczalniki Dzialanie korodujace na miedz\nZakres 1a – 4c (skala)\nMetoda wizualna PN-EN ISO 2160:2004","categories":["petro","materials"],"row_index":440,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6fe","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki, Wyroby chemiczne: rozpuszczalniki","methodology":"Zawartość siarki","parameters":[{"name":"Zakres","range":"(3 – 500) mg/kg"}],"technique":"Metoda fluorescencji w nadfiolecie","techniques":["Metoda fluorescencji w nadfiolecie"],"computed":[],"activity":"Zawartość siarki\nZakres (3 – 500) mg/kg\nMetoda fluorescencji w nadfiolecie","reference":"PN-EN ISO 20846:2020-03","norm_bases":["PN-EN ISO 20846:2020-03"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki, Wyroby chemiczne: rozpuszczalniki Zawartość siarki\nZakres (3 – 500) mg/kg\nMetoda fluorescencji w nadfiolecie PN-EN ISO 20846:2020-03 Paliwa ciekle: benzyna bezolowiowa, olej napedowy, olej opalowy lekki, Wyroby chemiczne: rozpuszczalniki Zawartosc siarki\nZakres (3 – 500) mg/kg\nMetoda fluorescencji w nadfiolecie PN-EN ISO 20846:2020-03","categories":["petro"],"row_index":441,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb6ff","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy","methodology":"Stabilność oksydacyjna","parameters":[{"name":"Zakres","range":"(5,0 – 50,0) h"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Stabilność oksydacyjna\nZakres (5,0 – 50,0) h\nMetoda konduktometryczna","reference":"PN-EN 15751:2014-05","norm_bases":["PN-EN 15751:2014-05"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy Stabilność oksydacyjna\nZakres (5,0 – 50,0) h\nMetoda konduktometryczna PN-EN 15751:2014-05 Paliwa ciekle: olej napedowy Stabilnosc oksydacyjna\nZakres (5,0 – 50,0) h\nMetoda konduktometryczna PN-EN 15751:2014-05","categories":["petro"],"row_index":442,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb700","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Stabilność oksydacyjna","parameters":[{"name":"Zakres","range":"(1,0 – 16,0) h"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Stabilność oksydacyjna\nZakres (1,0 – 16,0) h\nMetoda konduktometryczna","reference":"PN-EN 15751:2014-05","norm_bases":["PN-EN 15751:2014-05"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Stabilność oksydacyjna\nZakres (1,0 – 16,0) h\nMetoda konduktometryczna PN-EN 15751:2014-05 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Stabilnosc oksydacyjna\nZakres (1,0 – 16,0) h\nMetoda konduktometryczna PN-EN 15751:2014-05","categories":["petro"],"row_index":443,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb701","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej opałowy lekki","methodology":"Zawartość siarki","parameters":[{"name":"Zakres","range":"(0,03 – 1,2) %(m/m)"}],"technique":"Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii","techniques":["Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii"],"computed":[],"activity":"Zawartość siarki\nZakres (0,03 – 1,2) %(m/m)\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii","reference":"PN-EN ISO 8754:2007+Ap1:2014-02","norm_bases":["PN-EN ISO 8754:2007+Ap1:2014-02"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej opałowy lekki Zawartość siarki\nZakres (0,03 – 1,2) %(m/m)\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii PN-EN ISO 8754:2007+Ap1:2014-02 Paliwa ciekle: olej opalowy lekki Zawartosc siarki\nZakres (0,03 – 1,2) %(m/m)\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersja energii PN-EN ISO 8754:2007+Ap1:2014-02","categories":["petro"],"row_index":444,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb702","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki","methodology":"Lepkość kinematyczna w temperaturze 40 °C","parameters":[{"name":"Zakres","range":"(2,000 – 10,00) mm2/s"}],"technique":"Metoda kapilarna","techniques":["Metoda kapilarna"],"computed":[],"activity":"Lepkość kinematyczna w temperaturze 40 °C\nZakres (2,000 – 10,00) mm2/s\nMetoda kapilarna","reference":"PN-EN ISO 3104:2024-01 Procedura A","norm_bases":["PN-EN ISO 3104:2024-01 Procedura A"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki Lepkość kinematyczna w temperaturze 40 °C\nZakres (2,000 – 10,00) mm2/s\nMetoda kapilarna PN-EN ISO 3104:2024-01 Procedura A Paliwa ciekle: olej napedowy, olej opalowy lekki Lepkosc kinematyczna w temperaturze 40 °C\nZakres (2,000 – 10,00) mm2/s\nMetoda kapilarna PN-EN ISO 3104:2024-01 Procedura A","categories":["petro"],"row_index":445,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb703","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki","methodology":"Temperatura zapłonu","parameters":[{"name":"Zakres","range":"(40,0 – 100,0) °C"}],"technique":"Metoda zamkniętego tygla Pensky’ego-Martensa","techniques":["Metoda zamkniętego tygla Pensky’ego-Martensa"],"computed":[],"activity":"Temperatura zapłonu\nZakres (40,0 – 100,0) °C\nMetoda zamkniętego tygla Pensky’ego-Martensa","reference":"PN-EN ISO 2719:2016-08+A1:2021-06","norm_bases":["PN-EN ISO 2719:2016-08+A1:2021-06"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki Temperatura zapłonu\nZakres (40,0 – 100,0) °C\nMetoda zamkniętego tygla Pensky’ego-Martensa PN-EN ISO 2719:2016-08+A1:2021-06 Paliwa ciekle: olej napedowy, olej opalowy lekki Temperatura zaplonu\nZakres (40,0 – 100,0) °C\nMetoda zamknietego tygla Pensky’ego-Martensa PN-EN ISO 2719:2016-08+A1:2021-06","categories":["petro"],"row_index":446,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb704","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki","methodology":"Zawartość zanieczyszczeń","parameters":[{"name":"Zakres","range":"(12,0 – 26,0) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość zanieczyszczeń\nZakres (12,0 – 26,0) mg/kg\nMetoda wagowa","reference":"PN-EN 12662-1:2024-11","norm_bases":["PN-EN 12662-1:2024-11"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki Zawartość zanieczyszczeń\nZakres (12,0 – 26,0) mg/kg\nMetoda wagowa PN-EN 12662-1:2024-11 Paliwa ciekle: olej napedowy, olej opalowy lekki Zawartosc zanieczyszczen\nZakres (12,0 – 26,0) mg/kg\nMetoda wagowa PN-EN 12662-1:2024-11","categories":["petro"],"row_index":447,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb705","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki","methodology":"Indeks cetanowy (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Indeks cetanowy (z obliczeń)","reference":"PN-EN ISO 4264:2018-08","norm_bases":["PN-EN ISO 4264:2018-08"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki Indeks cetanowy (z obliczeń) PN-EN ISO 4264:2018-08 Paliwa ciekle: olej napedowy, olej opalowy lekki Indeks cetanowy (z obliczen) PN-EN ISO 4264:2018-08","categories":["petro"],"row_index":448,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb706","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki","methodology":"Temperatura zablokowania zimnego filtru","parameters":[{"name":"[0","range":"(-30)] oC"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Temperatura zablokowania zimnego filtru\n[0 (-30)] oC\nMetoda optyczna","reference":"PN-EN 116:2015-09","norm_bases":["PN-EN 116:2015-09"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki Temperatura zablokowania zimnego filtru\n[0 (-30)] oC\nMetoda optyczna PN-EN 116:2015-09 Paliwa ciekle: olej napedowy, olej opalowy lekki Temperatura zablokowania zimnego filtru\n[0 (-30)] oC\nMetoda optyczna PN-EN 116:2015-09","categories":["petro"],"row_index":449,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb707","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki","methodology":"Temperatura płynięcia","parameters":[{"name":"[10","range":"(-40,0)] oC"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Temperatura płynięcia\n[10 (-40,0)] oC\nMetoda optyczna","reference":"PN-EN ISO 3016:2019-06 | ASTM D 97-17b(2022)","norm_bases":["PN-EN ISO 3016:2019-06","ASTM D 97-17b(2022)"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki Temperatura płynięcia\n[10 (-40,0)] oC\nMetoda optyczna PN-EN ISO 3016:2019-06 | ASTM D 97-17b(2022) Paliwa ciekle: olej napedowy, olej opalowy lekki Temperatura plyniecia\n[10 (-40,0)] oC\nMetoda optyczna PN-EN ISO 3016:2019-06 | ASTM D 97-17b(2022)","categories":["petro"],"row_index":450,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb708","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki","methodology":"Zawartość wody","parameters":[{"name":"Zakres","range":"(30 – 1000) mg/kg"}],"technique":"Metoda miareczkowania kulometrycznego","techniques":["Metoda miareczkowania kulometrycznego"],"computed":[],"activity":"Zawartość wody\nZakres (30 – 1000) mg/kg\nMetoda miareczkowania kulometrycznego","reference":"PN-EN ISO 12937:2005+Ap1:2021-11","norm_bases":["PN-EN ISO 12937:2005+Ap1:2021-11"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki Zawartość wody\nZakres (30 – 1000) mg/kg\nMetoda miareczkowania kulometrycznego PN-EN ISO 12937:2005+Ap1:2021-11 Paliwa ciekle: olej napedowy, olej opalowy lekki Zawartosc wody\nZakres (30 – 1000) mg/kg\nMetoda miareczkowania kulometrycznego PN-EN ISO 12937:2005+Ap1:2021-11","categories":["petro","water"],"row_index":451,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb709","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki","methodology":"Temperatura mętnienia","parameters":[{"name":"[0","range":"(-45)] oC"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Temperatura mętnienia\n[0 (-45)] oC\nMetoda optyczna","reference":"PN-EN ISO 3015:2019-06","norm_bases":["PN-EN ISO 3015:2019-06"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki Temperatura mętnienia\n[0 (-45)] oC\nMetoda optyczna PN-EN ISO 3015:2019-06 Paliwa ciekle: olej napedowy, olej opalowy lekki Temperatura metnienia\n[0 (-45)] oC\nMetoda optyczna PN-EN ISO 3015:2019-06","categories":["petro"],"row_index":452,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb70a","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki","methodology":"Zawartość barwnika Solvent Red 19","parameters":[{"name":"Zakres","range":"(1,0 – 10,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość barwnika Solvent Red 19\nZakres (1,0 – 10,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-C-04426:2013-07 Metoda A","norm_bases":["PN-C-04426:2013-07 Metoda A"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki Zawartość barwnika Solvent Red 19\nZakres (1,0 – 10,0) mg/l\nMetoda spektrofotometryczna PN-C-04426:2013-07 Metoda A Paliwa ciekle: olej napedowy, olej opalowy lekki Zawartosc barwnika Solvent Red 19\nZakres (1,0 – 10,0) mg/l\nMetoda spektrofotometryczna PN-C-04426:2013-07 Metoda A","categories":["petro"],"row_index":453,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb70b","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki","methodology":"Zawartość estrów metylowych kwasów tłuszczowych (FAME)","parameters":[{"name":"Zakres","range":"(0,05 –10,0) %(v/v)"}],"technique":"Metoda spektrometrii w zakresie podczerwieni IR","techniques":["Metoda spektrometrii w zakresie podczerwieni IR"],"computed":[],"activity":"Zawartość estrów metylowych kwasów tłuszczowych (FAME)\nZakres (0,05 –10,0) %(v/v)\nMetoda spektrometrii w zakresie podczerwieni IR","reference":"PN-EN 14078:2014-06","norm_bases":["PN-EN 14078:2014-06"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki Zawartość estrów metylowych kwasów tłuszczowych (FAME)\nZakres (0,05 –10,0) %(v/v)\nMetoda spektrometrii w zakresie podczerwieni IR PN-EN 14078:2014-06 Paliwa ciekle: olej napedowy, olej opalowy lekki Zawartosc estrow metylowych kwasow tluszczowych (FAME)\nZakres (0,05 –10,0) %(v/v)\nMetoda spektrometrii w zakresie podczerwieni IR PN-EN 14078:2014-06","categories":["petro"],"row_index":454,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb70c","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość zanieczyszczeń","parameters":[{"name":"Zakres","range":"(5,0 – 27,0) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość zanieczyszczeń\nZakres (5,0 – 27,0) mg/kg\nMetoda wagowa","reference":"PN-EN 12662-2:2024-11","norm_bases":["PN-EN 12662-2:2024-11"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Zawartość zanieczyszczeń\nZakres (5,0 – 27,0) mg/kg\nMetoda wagowa PN-EN 12662-2:2024-11 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Zawartosc zanieczyszczen\nZakres (5,0 – 27,0) mg/kg\nMetoda wagowa PN-EN 12662-2:2024-11","categories":["petro"],"row_index":455,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb70d","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ropa naftowa","methodology":"Gęstość w temperaturze 15°C","parameters":[{"name":"Zakres","range":"(700,0 – 900,0) kg/m3"}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"computed":[],"activity":"Gęstość w temperaturze 15°C\nZakres (700,0 – 900,0) kg/m3\nMetoda oscylacyjna","reference":"PN-EN ISO 12185:2024-08","norm_bases":["PN-EN ISO 12185:2024-08"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ropa naftowa Gęstość w temperaturze 15°C\nZakres (700,0 – 900,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08 Ropa naftowa Gestosc w temperaturze 15°C\nZakres (700,0 – 900,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08","categories":["petro"],"row_index":456,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb70e","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ropa naftowa, Paliwa ciekłe: olej opałowy ciężki","methodology":"Zawartość zanieczyszczeń","parameters":[{"name":"Zakres","range":"(0,01 – 0,40) %(m/m)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość zanieczyszczeń\nZakres (0,01 – 0,40) %(m/m)\nMetoda wagowa","reference":"PN-EN ISO 3735:2001","norm_bases":["PN-EN ISO 3735:2001"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ropa naftowa, Paliwa ciekłe: olej opałowy ciężki Zawartość zanieczyszczeń\nZakres (0,01 – 0,40) %(m/m)\nMetoda wagowa PN-EN ISO 3735:2001 Ropa naftowa, Paliwa ciekle: olej opalowy ciezki Zawartosc zanieczyszczen\nZakres (0,01 – 0,40) %(m/m)\nMetoda wagowa PN-EN ISO 3735:2001","categories":["petro"],"row_index":457,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb70f","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Wyroby chemiczne: płyny niskokrzepnące","methodology":"Temperatura krystalizacji","parameters":[{"name":"[(-18)","range":"(-50)] oC"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Temperatura krystalizacji\n[(-18) (-50)] oC\nMetoda wizualna","reference":"PN-93/C-40008/10","norm_bases":["PN-93/C-40008/10"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby chemiczne: płyny niskokrzepnące Temperatura krystalizacji\n[(-18) (-50)] oC\nMetoda wizualna PN-93/C-40008/10 Wyroby chemiczne: plyny niskokrzepnace Temperatura krystalizacji\n[(-18) (-50)] oC\nMetoda wizualna PN-93/C-40008/10","categories":["other"],"row_index":458,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb710","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiały smarne: oleje bazowe, oleje silnikowe, przemysłowe oleje smarowe","methodology":"Właściwości przeciwkorozyjne olejów mineralnych (korozja na trzpieniu stalowym)","parameters":[],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Właściwości przeciwkorozyjne olejów mineralnych (korozja na trzpieniu stalowym)\nMetoda wizualna","reference":"PN-ISO 7120:2011 Procedura A i B","norm_bases":["PN-ISO 7120:2011 Procedura A i B"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały smarne: oleje bazowe, oleje silnikowe, przemysłowe oleje smarowe Właściwości przeciwkorozyjne olejów mineralnych (korozja na trzpieniu stalowym)\nMetoda wizualna PN-ISO 7120:2011 Procedura A i B Materialy smarne: oleje bazowe, oleje silnikowe, przemyslowe oleje smarowe Wlasciwosci przeciwkorozyjne olejow mineralnych (korozja na trzpieniu stalowym)\nMetoda wizualna PN-ISO 7120:2011 Procedura A i B","categories":["materials","petro"],"row_index":459,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb711","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiały smarne: oleje bazowe, oleje silnikowe, przemysłowe oleje smarowe","methodology":"Lepkość kinematyczna w temperaturze 40 °C i 100 °C","parameters":[{"name":"Zakres","range":"(2,000 – 1200) mm2/s"}],"technique":"Metoda kapilarna","techniques":["Metoda kapilarna"],"computed":[],"activity":"Lepkość kinematyczna w temperaturze 40 °C i 100 °C\nZakres (2,000 – 1200) mm2/s\nMetoda kapilarna","reference":"PN-EN ISO 3104:2024-01 Procedura A","norm_bases":["PN-EN ISO 3104:2024-01 Procedura A"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały smarne: oleje bazowe, oleje silnikowe, przemysłowe oleje smarowe Lepkość kinematyczna w temperaturze 40 °C i 100 °C\nZakres (2,000 – 1200) mm2/s\nMetoda kapilarna PN-EN ISO 3104:2024-01 Procedura A Materialy smarne: oleje bazowe, oleje silnikowe, przemyslowe oleje smarowe Lepkosc kinematyczna w temperaturze 40 °C i 100 °C\nZakres (2,000 – 1200) mm2/s\nMetoda kapilarna PN-EN ISO 3104:2024-01 Procedura A","categories":["materials","petro"],"row_index":460,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb712","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiały smarne: oleje bazowe, oleje silnikowe, przemysłowe oleje smarowe","methodology":"Temperatura płynięcia","parameters":[{"name":"[10","range":"(-45)] oC"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Temperatura płynięcia\n[10 (-45)] oC\nMetoda optyczna","reference":"PN-EN ISO 3016:2019-06","norm_bases":["PN-EN ISO 3016:2019-06"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały smarne: oleje bazowe, oleje silnikowe, przemysłowe oleje smarowe Temperatura płynięcia\n[10 (-45)] oC\nMetoda optyczna PN-EN ISO 3016:2019-06 Materialy smarne: oleje bazowe, oleje silnikowe, przemyslowe oleje smarowe Temperatura plyniecia\n[10 (-45)] oC\nMetoda optyczna PN-EN ISO 3016:2019-06","categories":["materials","petro"],"row_index":461,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb713","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiały smarne: oleje bazowe, oleje silnikowe, przemysłowe oleje smarowe","methodology":"Gęstość","parameters":[{"name":"Zakres","range":"(800,0 – 900,0) kg/m3"}],"technique":"Metoda areometryczna","techniques":["Metoda areometryczna"],"computed":[],"activity":"Gęstość\nZakres (800,0 – 900,0) kg/m3\nMetoda areometryczna","reference":"PN-EN ISO 3675:2004","norm_bases":["PN-EN ISO 3675:2004"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały smarne: oleje bazowe, oleje silnikowe, przemysłowe oleje smarowe Gęstość\nZakres (800,0 – 900,0) kg/m3\nMetoda areometryczna PN-EN ISO 3675:2004 Materialy smarne: oleje bazowe, oleje silnikowe, przemyslowe oleje smarowe Gestosc\nZakres (800,0 – 900,0) kg/m3\nMetoda areometryczna PN-EN ISO 3675:2004","categories":["materials","petro"],"row_index":462,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb714","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiały smarne: oleje bazowe, oleje silnikowe, przemysłowe oleje smarowe","methodology":"Temperatura zapłonu","parameters":[{"name":"Zakres","range":"(80,0 – 280,0) °C"}],"technique":"Metoda otwartego tygla Cleveland’a","techniques":["Metoda otwartego tygla Cleveland’a"],"computed":[],"activity":"Temperatura zapłonu\nZakres (80,0 – 280,0) °C\nMetoda otwartego tygla Cleveland’a","reference":"PN-EN ISO 2592:2017-10","norm_bases":["PN-EN ISO 2592:2017-10"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały smarne: oleje bazowe, oleje silnikowe, przemysłowe oleje smarowe Temperatura zapłonu\nZakres (80,0 – 280,0) °C\nMetoda otwartego tygla Cleveland’a PN-EN ISO 2592:2017-10 Materialy smarne: oleje bazowe, oleje silnikowe, przemyslowe oleje smarowe Temperatura zaplonu\nZakres (80,0 – 280,0) °C\nMetoda otwartego tygla Cleveland’a PN-EN ISO 2592:2017-10","categories":["materials","petro"],"row_index":463,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb715","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiały smarne: oleje bazowe, oleje silnikowe, przemysłowe oleje smarowe","methodology":"Gęstość w temperaturze 15°C","parameters":[{"name":"Zakres","range":"(800,0 – 900,0) kg/m3"}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"computed":[],"activity":"Gęstość w temperaturze 15°C\nZakres (800,0 – 900,0) kg/m3\nMetoda oscylacyjna","reference":"PN-EN ISO 12185:2024-08","norm_bases":["PN-EN ISO 12185:2024-08"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały smarne: oleje bazowe, oleje silnikowe, przemysłowe oleje smarowe Gęstość w temperaturze 15°C\nZakres (800,0 – 900,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08 Materialy smarne: oleje bazowe, oleje silnikowe, przemyslowe oleje smarowe Gestosc w temperaturze 15°C\nZakres (800,0 – 900,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08","categories":["materials","petro"],"row_index":464,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb716","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiały smarne: oleje bazowe, oleje silnikowe, przemysłowe oleje smarowe","methodology":"Pozostałość po spopieleniu","parameters":[{"name":"Zakres","range":"(0,001 – 0,18) %(m/m)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Pozostałość po spopieleniu\nZakres (0,001 – 0,18) %(m/m)\nMetoda wagowa","reference":"PN-EN ISO 6245:2008","norm_bases":["PN-EN ISO 6245:2008"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały smarne: oleje bazowe, oleje silnikowe, przemysłowe oleje smarowe Pozostałość po spopieleniu\nZakres (0,001 – 0,18) %(m/m)\nMetoda wagowa PN-EN ISO 6245:2008 Materialy smarne: oleje bazowe, oleje silnikowe, przemyslowe oleje smarowe Pozostalosc po spopieleniu\nZakres (0,001 – 0,18) %(m/m)\nMetoda wagowa PN-EN ISO 6245:2008","categories":["materials","petro"],"row_index":465,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb717","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiały smarne: oleje bazowe, oleje silnikowe, przemysłowe oleje smarowe","methodology":"Działanie korodujące na miedź","parameters":[{"name":"Zakres","range":"1a – 4c (skala)"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Działanie korodujące na miedź\nZakres 1a – 4c (skala)\nMetoda wizualna","reference":"PN-EN ISO 2160:2004","norm_bases":["PN-EN ISO 2160:2004"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały smarne: oleje bazowe, oleje silnikowe, przemysłowe oleje smarowe Działanie korodujące na miedź\nZakres 1a – 4c (skala)\nMetoda wizualna PN-EN ISO 2160:2004 Materialy smarne: oleje bazowe, oleje silnikowe, przemyslowe oleje smarowe Dzialanie korodujace na miedz\nZakres 1a – 4c (skala)\nMetoda wizualna PN-EN ISO 2160:2004","categories":["materials","petro"],"row_index":466,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb718","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiały smarne: oleje bazowe, oleje silnikowe, przemysłowe oleje smarowe","methodology":"Działanie korodujące na metale","parameters":[],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Działanie korodujące na metale\nMetoda wizualna","reference":"PN-85/C-04093 metoda B","norm_bases":["PN-85/C-04093 metoda B"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały smarne: oleje bazowe, oleje silnikowe, przemysłowe oleje smarowe Działanie korodujące na metale\nMetoda wizualna PN-85/C-04093 metoda B Materialy smarne: oleje bazowe, oleje silnikowe, przemyslowe oleje smarowe Dzialanie korodujace na metale\nMetoda wizualna PN-85/C-04093 metoda B","categories":["materials","petro"],"row_index":467,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb719","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiały smarne: oleje bazowe, przemysłowe oleje smarowe","methodology":"Zdolność wydzielania powietrza","parameters":[{"name":"Zakres","range":"(1 – 15) minut"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zdolność wydzielania powietrza\nZakres (1 – 15) minut\nMetoda wagowa","reference":"PN-ISO 9120:2009+Ap1:2022-04","norm_bases":["PN-ISO 9120:2009+Ap1:2022-04"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały smarne: oleje bazowe, przemysłowe oleje smarowe Zdolność wydzielania powietrza\nZakres (1 – 15) minut\nMetoda wagowa PN-ISO 9120:2009+Ap1:2022-04 Materialy smarne: oleje bazowe, przemyslowe oleje smarowe Zdolnosc wydzielania powietrza\nZakres (1 – 15) minut\nMetoda wagowa PN-ISO 9120:2009+Ap1:2022-04","categories":["materials","petro"],"row_index":468,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb71a","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiały smarne: smary","methodology":"Temperatura kroplenia","parameters":[{"name":"Zakres","range":"(70 − 230) °C"}],"technique":"Metoda Ubbelohde`a","techniques":["Metoda Ubbelohde`a"],"computed":[],"activity":"Temperatura kroplenia\nZakres (70 − 230) °C\nMetoda Ubbelohde`a","reference":"PN-55/C-04020","norm_bases":["PN-55/C-04020"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały smarne: smary Temperatura kroplenia\nZakres (70 − 230) °C\nMetoda Ubbelohde`a PN-55/C-04020 Materialy smarne: smary Temperatura kroplenia\nZakres (70 − 230) °C\nMetoda Ubbelohde`a PN-55/C-04020","categories":["materials","petro"],"row_index":469,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb71b","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiały smarne: smary","methodology":"Temperatura kroplenia","parameters":[{"name":"Zakres","range":"(130 – 300) °C"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Temperatura kroplenia\nZakres (130 – 300) °C\nMetoda wizualna","reference":"PN-ISO 2176:2011+A1:2021-07","norm_bases":["PN-ISO 2176:2011+A1:2021-07"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały smarne: smary Temperatura kroplenia\nZakres (130 – 300) °C\nMetoda wizualna PN-ISO 2176:2011+A1:2021-07 Materialy smarne: smary Temperatura kroplenia\nZakres (130 – 300) °C\nMetoda wizualna PN-ISO 2176:2011+A1:2021-07","categories":["materials","petro"],"row_index":470,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb71c","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiały smarne: smary","methodology":"Penetracja","parameters":[{"name":"Zakres","range":"200 – 420"}],"technique":"Metoda penetracji stożkiem","techniques":["Metoda penetracji stożkiem"],"computed":[],"activity":"Penetracja\nZakres 200 – 420\nMetoda penetracji stożkiem","reference":"PN-ISO 2137:2021-07","norm_bases":["PN-ISO 2137:2021-07"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały smarne: smary Penetracja\nZakres 200 – 420\nMetoda penetracji stożkiem PN-ISO 2137:2021-07 Materialy smarne: smary Penetracja\nZakres 200 – 420\nMetoda penetracji stozkiem PN-ISO 2137:2021-07","categories":["materials","petro"],"row_index":471,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb71d","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki, wody opadowe","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[{"name":"Temperatura pobranej próbki wody opadowej, ścieków"},{"name":"Zakres","range":"(2,0 – 30,0) °C"}],"technique":"Metoda manualna","techniques":["Metoda manualna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura pobranej próbki wody opadowej, ścieków\nZakres (2,0 – 30,0) °C\nMetoda manualna","reference":"PN-ISO 5667-10:2021-11 Metoda nr 111 Wydanie 5 z dnia 01.07.2020","norm_bases":["PN-ISO 5667-10:2021-11 Metoda nr 111 Wydanie 5 z dnia 01.07.2020"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, wody opadowe Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura pobranej próbki wody opadowej, ścieków\nZakres (2,0 – 30,0) °C\nMetoda manualna PN-ISO 5667-10:2021-11 Metoda nr 111 Wydanie 5 z dnia 01.07.2020 Scieki, wody opadowe Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nTemperatura pobranej probki wody opadowej, sciekow\nZakres (2,0 – 30,0) °C\nMetoda manualna PN-ISO 5667-10:2021-11 Metoda nr 111 Wydanie 5 z dnia 01.07.2020","categories":["water"],"row_index":472,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb71e","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Scieki pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":473,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb71f","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(5 – 200) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (5 – 200) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Zawiesiny ogólne\nZakres (5 – 200) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Scieki Zawiesiny ogolne\nZakres (5 – 200) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":474,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb720","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie fenolu (indeks fenolowy)","parameters":[{"name":"Zakres","range":"(0,002 – 0,100) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fenolu (indeks fenolowy)\nZakres (0,002 – 0,100) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6439:1994 metoda B","norm_bases":["PN-ISO 6439:1994 metoda B"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie fenolu (indeks fenolowy)\nZakres (0,002 – 0,100) mg/l\nMetoda spektrofotometryczna PN-ISO 6439:1994 metoda B Scieki Stezenie fenolu (indeks fenolowy)\nZakres (0,002 – 0,100) mg/l\nMetoda spektrofotometryczna PN-ISO 6439:1994 metoda B","categories":["water"],"row_index":475,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb721","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"Indeks oleju mineralnego","parameters":[{"name":"Zakres","range":"(2,0 – 1000,0) mg/l"}],"technique":"Metoda spektroskopii laserowej","techniques":["Metoda spektroskopii laserowej"],"computed":[],"activity":"Indeks oleju mineralnego\nZakres (2,0 – 1000,0) mg/l\nMetoda spektroskopii laserowej","reference":"ASTM D 7678-17(2022)","norm_bases":["ASTM D 7678-17(2022)"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Indeks oleju mineralnego\nZakres (2,0 – 1000,0) mg/l\nMetoda spektroskopii laserowej ASTM D 7678-17(2022) Scieki Indeks oleju mineralnego\nZakres (2,0 – 1000,0) mg/l\nMetoda spektroskopii laserowej ASTM D 7678-17(2022)","categories":["water","petro"],"row_index":476,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb722","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5 – 150) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5 – 150) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie chlorków\nZakres (5 – 150) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Scieki Stezenie chlorkow\nZakres (5 – 150) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":477,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb723","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu BZT5","parameters":[{"name":"Zakres","range":"(3 – 600) mg O2/l"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu BZT5\nZakres (3 – 600) mg O2/l\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu BZT5\nZakres (3 – 600) mg O2/l\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Scieki Biochemiczne zapotrzebowanie tlenu BZT5\nZakres (3 – 600) mg O2/l\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":478,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb724","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"Chemiczne zapotrzebowanie tlenu","parameters":[{"name":"Zakres","range":"(30,0 – 1000) mg O2/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu\nZakres (30,0 – 1000) mg O2/l\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Chemiczne zapotrzebowanie tlenu\nZakres (30,0 – 1000) mg O2/l\nMetoda spektrofotometryczna PN-ISO 15705:2005 Scieki Chemiczne zapotrzebowanie tlenu\nZakres (30,0 – 1000) mg O2/l\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":479,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb725","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie fosforu","parameters":[{"name":"Zakres","range":"(0,10 – 25,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu\nZakres (0,10 – 25,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 pkt 8","norm_bases":["PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 pkt 8"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie fosforu\nZakres (0,10 – 25,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 pkt 8 Scieki Stezenie fosforu\nZakres (0,10 – 25,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 pkt 8","categories":["water"],"row_index":480,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb726","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki, biopaliwa ciekłe: bioetanol, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Pobieranie próbek ze zbiorników do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek ze zbiorników do badań chemicznych i fizycznych","reference":"PN-EN ISO 3170:2025-12 z wyłączeniem 8.3.1.3- 8.3.1.6, 8.3.1.8, 8.3.2, 8.7- 8.9, 9.8, 10.6, 10.7","norm_bases":["PN-EN ISO 3170:2025-12 z wyłączeniem 8.3.1.3- 8.3.1.6, 8.3.1.8, 8.3.2, 8.7- 8.9, 9.8, 10.6, 10.7"],"lab_section":"Punkt Obsługi Laboratoryjnej w Ostrowie Wielkopolskim PP7/3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki, biopaliwa ciekłe: bioetanol, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Pobieranie próbek ze zbiorników do badań chemicznych i fizycznych PN-EN ISO 3170:2025-12 z wyłączeniem 8.3.1.3- 8.3.1.6, 8.3.1.8, 8.3.2, 8.7- 8.9, 9.8, 10.6, 10.7 Paliwa ciekle: benzyna bezolowiowa, olej napedowy, olej opalowy lekki, biopaliwa ciekle: bioetanol, biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Pobieranie probek ze zbiornikow do badan chemicznych i fizycznych PN-EN ISO 3170:2025-12 z wylaczeniem 8.3.1.3- 8.3.1.6, 8.3.1.8, 8.3.2, 8.7- 8.9, 9.8, 10.6, 10.7","categories":["petro"],"row_index":481,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb727","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki, biopaliwa ciekłe: bioetanol, estry metylowe kwasów tłuszczowych (FAME)","methodology":"Gęstość w temperaturze 15°C","parameters":[{"name":"Zakres","range":"(700,0 – 900,0) kg/m3"}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"computed":[],"activity":"Gęstość w temperaturze 15°C\nZakres (700,0 – 900,0) kg/m3\nMetoda oscylacyjna","reference":"PN-EN ISO 12185:2024-08","norm_bases":["PN-EN ISO 12185:2024-08"],"lab_section":"Punkt Obsługi Laboratoryjnej w Ostrowie Wielkopolskim PP7/3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki, biopaliwa ciekłe: bioetanol, estry metylowe kwasów tłuszczowych (FAME) Gęstość w temperaturze 15°C\nZakres (700,0 – 900,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08 Paliwa ciekle: benzyna bezolowiowa, olej napedowy, olej opalowy lekki, biopaliwa ciekle: bioetanol, estry metylowe kwasow tluszczowych (FAME) Gestosc w temperaturze 15°C\nZakres (700,0 – 900,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08","categories":["petro"],"row_index":482,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb728","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki","methodology":"Skład frakcyjny","parameters":[{"name":"Zakres","range":"(30,0 – 370,0) °C"}],"technique":"Metoda destylacyjna","techniques":["Metoda destylacyjna"],"computed":[],"activity":"Skład frakcyjny\nZakres (30,0 – 370,0) °C\nMetoda destylacyjna","reference":"PN-EN ISO 3405:2019-05","norm_bases":["PN-EN ISO 3405:2019-05"],"lab_section":"Punkt Obsługi Laboratoryjnej w Ostrowie Wielkopolskim PP7/3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki Skład frakcyjny\nZakres (30,0 – 370,0) °C\nMetoda destylacyjna PN-EN ISO 3405:2019-05 Paliwa ciekle: benzyna bezolowiowa, olej napedowy, olej opalowy lekki Sklad frakcyjny\nZakres (30,0 – 370,0) °C\nMetoda destylacyjna PN-EN ISO 3405:2019-05","categories":["petro"],"row_index":483,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb729","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki","methodology":"Zawartość siarki","parameters":[{"name":"Zakres","range":"(3,0 – 100) mg/kg"}],"technique":"Metoda fluorescencji w nadfiolecie","techniques":["Metoda fluorescencji w nadfiolecie"],"computed":[],"activity":"Zawartość siarki\nZakres (3,0 – 100) mg/kg\nMetoda fluorescencji w nadfiolecie","reference":"PN-EN ISO 20846:2020-03","norm_bases":["PN-EN ISO 20846:2020-03"],"lab_section":"Punkt Obsługi Laboratoryjnej w Ostrowie Wielkopolskim PP7/3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki Zawartość siarki\nZakres (3,0 – 100) mg/kg\nMetoda fluorescencji w nadfiolecie PN-EN ISO 20846:2020-03 Paliwa ciekle: benzyna bezolowiowa, olej napedowy, olej opalowy lekki Zawartosc siarki\nZakres (3,0 – 100) mg/kg\nMetoda fluorescencji w nadfiolecie PN-EN ISO 20846:2020-03","categories":["petro"],"row_index":484,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb72a","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Prężność par nasyconych powietrzem","parameters":[{"name":"Zakres","range":"(40,0 – 106,0) kPa"}],"technique":"Metoda mini Reid","techniques":["Metoda mini Reid"],"computed":[],"activity":"Prężność par nasyconych powietrzem\nZakres (40,0 – 106,0) kPa\nMetoda mini Reid","reference":"PN-EN 13016-1:2024-11","norm_bases":["PN-EN 13016-1:2024-11"],"lab_section":"Punkt Obsługi Laboratoryjnej w Ostrowie Wielkopolskim PP7/3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Prężność par nasyconych powietrzem\nZakres (40,0 – 106,0) kPa\nMetoda mini Reid PN-EN 13016-1:2024-11 Paliwa ciekle: benzyna bezolowiowa Preznosc par nasyconych powietrzem\nZakres (40,0 – 106,0) kPa\nMetoda mini Reid PN-EN 13016-1:2024-11","categories":["petro","environment"],"row_index":485,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb72b","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Zawartość tlenowych związków organicznych","parameters":[{"name":"Zakres","range":"(0,17 – 15,0) %(v/v)"},{"name":"Całkowita zawartość organicznie związanego tlenu (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość tlenowych związków organicznych\nZakres:\nZakres (0,17 – 15,0) %(v/v)\nCałkowita zawartość organicznie związanego tlenu (z obliczeń)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13132:2005","norm_bases":["PN-EN 13132:2005"],"lab_section":"Punkt Obsługi Laboratoryjnej w Ostrowie Wielkopolskim PP7/3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Zawartość tlenowych związków organicznych\nZakres:\nZakres (0,17 – 15,0) %(v/v)\nCałkowita zawartość organicznie związanego tlenu (z obliczeń)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13132:2005 Paliwa ciekle: benzyna bezolowiowa Zawartosc tlenowych zwiazkow organicznych\nZakres:\nZakres (0,17 – 15,0) %(v/v)\nCalkowita zawartosc organicznie zwiazanego tlenu (z obliczen)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13132:2005","categories":["petro"],"row_index":486,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb72c","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Indeks lotności (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Indeks lotności (z obliczeń)","reference":"PN-EN 228+A1:2017-06 p. 5.5.2","norm_bases":["PN-EN 228+A1:2017-06 p. 5.5.2"],"lab_section":"Punkt Obsługi Laboratoryjnej w Ostrowie Wielkopolskim PP7/3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Indeks lotności (z obliczeń) PN-EN 228+A1:2017-06 p. 5.5.2 Paliwa ciekle: benzyna bezolowiowa Indeks lotnosci (z obliczen) PN-EN 228+A1:2017-06 p. 5.5.2","categories":["petro"],"row_index":487,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb72d","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Liczba oktanowa LOM","parameters":[{"name":"Zakres","range":"84,0 – 90,0"}],"technique":"Metoda silnikowa","techniques":["Metoda silnikowa"],"computed":[],"activity":"Liczba oktanowa LOM\nZakres 84,0 – 90,0\nMetoda silnikowa","reference":"PN-EN ISO 5163:2014-08","norm_bases":["PN-EN ISO 5163:2014-08"],"lab_section":"Punkt Obsługi Laboratoryjnej w Ostrowie Wielkopolskim PP7/3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Liczba oktanowa LOM\nZakres 84,0 – 90,0\nMetoda silnikowa PN-EN ISO 5163:2014-08 Paliwa ciekle: benzyna bezolowiowa Liczba oktanowa LOM\nZakres 84,0 – 90,0\nMetoda silnikowa PN-EN ISO 5163:2014-08","categories":["petro"],"row_index":488,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb72e","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki","methodology":"Temperatura zapłonu","parameters":[{"name":"Zakres","range":"(45,0 – 75,0) °C"}],"technique":"Metoda zamkniętego tygla Pensky`ego-Martensa","techniques":["Metoda zamkniętego tygla Pensky`ego-Martensa"],"computed":[],"activity":"Temperatura zapłonu\nZakres (45,0 – 75,0) °C\nMetoda zamkniętego tygla Pensky`ego-Martensa","reference":"PN-EN ISO 2719:2016-08+A1:2021-06","norm_bases":["PN-EN ISO 2719:2016-08+A1:2021-06"],"lab_section":"Punkt Obsługi Laboratoryjnej w Ostrowie Wielkopolskim PP7/3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki Temperatura zapłonu\nZakres (45,0 – 75,0) °C\nMetoda zamkniętego tygla Pensky`ego-Martensa PN-EN ISO 2719:2016-08+A1:2021-06 Paliwa ciekle: olej napedowy, olej opalowy lekki Temperatura zaplonu\nZakres (45,0 – 75,0) °C\nMetoda zamknietego tygla Pensky`ego-Martensa PN-EN ISO 2719:2016-08+A1:2021-06","categories":["petro"],"row_index":489,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb72f","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki","methodology":"Zawartość zanieczyszczeń","parameters":[{"name":"Zakres","range":"(12,0 – 26,0) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość zanieczyszczeń\nZakres (12,0 – 26,0) mg/kg\nMetoda wagowa","reference":"PN-EN 12662-1:2024-11","norm_bases":["PN-EN 12662-1:2024-11"],"lab_section":"Punkt Obsługi Laboratoryjnej w Ostrowie Wielkopolskim PP7/3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki Zawartość zanieczyszczeń\nZakres (12,0 – 26,0) mg/kg\nMetoda wagowa PN-EN 12662-1:2024-11 Paliwa ciekle: olej napedowy, olej opalowy lekki Zawartosc zanieczyszczen\nZakres (12,0 – 26,0) mg/kg\nMetoda wagowa PN-EN 12662-1:2024-11","categories":["petro"],"row_index":490,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb730","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość wody","parameters":[{"name":"Zakres","range":"(30 – 1000) mg/kg"}],"technique":"Metoda miareczkowania kulometrycznego","techniques":["Metoda miareczkowania kulometrycznego"],"computed":[],"activity":"Zawartość wody\nZakres (30 – 1000) mg/kg\nMetoda miareczkowania kulometrycznego","reference":"PN-EN ISO 12937:2005+Ap1:2021-11","norm_bases":["PN-EN ISO 12937:2005+Ap1:2021-11"],"lab_section":"Punkt Obsługi Laboratoryjnej w Ostrowie Wielkopolskim PP7/3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Zawartość wody\nZakres (30 – 1000) mg/kg\nMetoda miareczkowania kulometrycznego PN-EN ISO 12937:2005+Ap1:2021-11 Paliwa ciekle: olej napedowy, olej opalowy lekki, biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Zawartosc wody\nZakres (30 – 1000) mg/kg\nMetoda miareczkowania kulometrycznego PN-EN ISO 12937:2005+Ap1:2021-11","categories":["petro","water"],"row_index":491,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb731","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość zanieczyszczeń","parameters":[{"name":"Zakres","range":"(5,0 – 27,0) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość zanieczyszczeń\nZakres (5,0 – 27,0) mg/kg\nMetoda wagowa","reference":"PN-EN 12662-2:2024-11","norm_bases":["PN-EN 12662-2:2024-11"],"lab_section":"Punkt Obsługi Laboratoryjnej w Ostrowie Wielkopolskim PP7/3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Zawartość zanieczyszczeń\nZakres (5,0 – 27,0) mg/kg\nMetoda wagowa PN-EN 12662-2:2024-11 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Zawartosc zanieczyszczen\nZakres (5,0 – 27,0) mg/kg\nMetoda wagowa PN-EN 12662-2:2024-11","categories":["petro"],"row_index":492,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb732","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Temperatura zablokowania zimnego filtra","parameters":[{"name":"[0 °C","range":"(-40)°C]"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Temperatura zablokowania zimnego filtra\n[0 °C (-40)°C]\nMetoda optyczna","reference":"PN-EN 116:2015-09","norm_bases":["PN-EN 116:2015-09"],"lab_section":"Punkt Obsługi Laboratoryjnej w Ostrowie Wielkopolskim PP7/3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Temperatura zablokowania zimnego filtra\n[0 °C (-40)°C]\nMetoda optyczna PN-EN 116:2015-09 Paliwa ciekle: olej napedowy, biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Temperatura zablokowania zimnego filtra\n[0 °C (-40)°C]\nMetoda optyczna PN-EN 116:2015-09","categories":["petro"],"row_index":493,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb733","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy","methodology":"Zawartość estrów metylowych kwasów tłuszczowych (FAME)","parameters":[{"name":"Zakres","range":"(3,0 – 10,0) %(v/v)"}],"technique":"Metoda spektrometrii w zakresie podczerwieni IR","techniques":["Metoda spektrometrii w zakresie podczerwieni IR"],"computed":[],"activity":"Zawartość estrów metylowych kwasów tłuszczowych (FAME)\nZakres (3,0 – 10,0) %(v/v)\nMetoda spektrometrii w zakresie podczerwieni IR","reference":"PN-EN 14078:2014-06","norm_bases":["PN-EN 14078:2014-06"],"lab_section":"Punkt Obsługi Laboratoryjnej w Ostrowie Wielkopolskim PP7/3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy Zawartość estrów metylowych kwasów tłuszczowych (FAME)\nZakres (3,0 – 10,0) %(v/v)\nMetoda spektrometrii w zakresie podczerwieni IR PN-EN 14078:2014-06 Paliwa ciekle: olej napedowy Zawartosc estrow metylowych kwasow tluszczowych (FAME)\nZakres (3,0 – 10,0) %(v/v)\nMetoda spektrometrii w zakresie podczerwieni IR PN-EN 14078:2014-06","categories":["petro"],"row_index":494,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb734","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy","methodology":"Indeks cetanowy (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Indeks cetanowy (z obliczeń)","reference":"PN-EN ISO 4264:2018-08","norm_bases":["PN-EN ISO 4264:2018-08"],"lab_section":"Punkt Obsługi Laboratoryjnej w Ostrowie Wielkopolskim PP7/3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy Indeks cetanowy (z obliczeń) PN-EN ISO 4264:2018-08 Paliwa ciekle: olej napedowy Indeks cetanowy (z obliczen) PN-EN ISO 4264:2018-08","categories":["petro"],"row_index":495,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb735","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy","methodology":"Liczba cetanowa","parameters":[{"name":"Zakres","range":"50,0 – 60,0"}],"technique":"Metoda silnikowa","techniques":["Metoda silnikowa"],"computed":[],"activity":"Liczba cetanowa\nZakres 50,0 – 60,0\nMetoda silnikowa","reference":"PN-EN ISO 5165:2021-02","norm_bases":["PN-EN ISO 5165:2021-02"],"lab_section":"Punkt Obsługi Laboratoryjnej w Ostrowie Wielkopolskim PP7/3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy Liczba cetanowa\nZakres 50,0 – 60,0\nMetoda silnikowa PN-EN ISO 5165:2021-02 Paliwa ciekle: olej napedowy Liczba cetanowa\nZakres 50,0 – 60,0\nMetoda silnikowa PN-EN ISO 5165:2021-02","categories":["petro"],"row_index":496,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb736","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych ( FAME)","methodology":"Skłonność do blokowania filtra po wychładzaniu","parameters":[{"name":"Zakres","range":"(30 – 360) s"}],"technique":"Metoda CSFT","techniques":["Metoda CSFT"],"computed":[],"activity":"Skłonność do blokowania filtra po wychładzaniu\nZakres (30 – 360) s\nMetoda CSFT","reference":"ASTM D 7501-22","norm_bases":["ASTM D 7501-22"],"lab_section":"Punkt Obsługi Laboratoryjnej w Ostrowie Wielkopolskim PP7/3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych ( FAME) Skłonność do blokowania filtra po wychładzaniu\nZakres (30 – 360) s\nMetoda CSFT ASTM D 7501-22 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych ( FAME) Sklonnosc do blokowania filtra po wychladzaniu\nZakres (30 – 360) s\nMetoda CSFT ASTM D 7501-22","categories":["petro"],"row_index":497,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb737","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych ( FAME)","methodology":"Stabilność oksydacyjna","parameters":[{"name":"Zakres","range":"(1,0 – 16,0) h"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Stabilność oksydacyjna\nZakres (1,0 – 16,0) h\nMetoda konduktometryczna","reference":"PN-EN 15751:2014-05","norm_bases":["PN-EN 15751:2014-05"],"lab_section":"Punkt Obsługi Laboratoryjnej w Ostrowie Wielkopolskim PP7/3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych ( FAME) Stabilność oksydacyjna\nZakres (1,0 – 16,0) h\nMetoda konduktometryczna PN-EN 15751:2014-05 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych ( FAME) Stabilnosc oksydacyjna\nZakres (1,0 – 16,0) h\nMetoda konduktometryczna PN-EN 15751:2014-05","categories":["petro"],"row_index":498,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb738","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Temperatura mętnienia","parameters":[{"name":"[0oC","range":"(-25) oC]"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Temperatura mętnienia\n[0oC (-25) oC]\nMetoda optyczna","reference":"PN-EN ISO 3015:2019-06","norm_bases":["PN-EN ISO 3015:2019-06"],"lab_section":"Punkt Obsługi Laboratoryjnej w Ostrowie Wielkopolskim PP7/3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Temperatura mętnienia\n[0oC (-25) oC]\nMetoda optyczna PN-EN ISO 3015:2019-06 Paliwa ciekle: olej napedowy, biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Temperatura metnienia\n[0oC (-25) oC]\nMetoda optyczna PN-EN ISO 3015:2019-06","categories":["petro"],"row_index":499,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb739","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: bioetanol","methodology":"Moc","parameters":[{"name":"Zakres","range":"(95,0 – 100,0) %(v/v)"}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"computed":[],"activity":"Moc\nZakres (95,0 – 100,0) %(v/v)\nMetoda oscylacyjna","reference":"PN-A-79528-3:2007 p. 5.2","norm_bases":["PN-A-79528-3:2007 p. 5.2"],"lab_section":"Punkt Obsługi Laboratoryjnej w Ostrowie Wielkopolskim PP7/3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: bioetanol Moc\nZakres (95,0 – 100,0) %(v/v)\nMetoda oscylacyjna PN-A-79528-3:2007 p. 5.2 Paliwa ciekle: biopaliwa ciekle: bioetanol Moc\nZakres (95,0 – 100,0) %(v/v)\nMetoda oscylacyjna PN-A-79528-3:2007 p. 5.2","categories":["petro"],"row_index":500,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb73a","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, biopaliwa ciekłe: olej napędowy z FAME","methodology":"Stabilność oksydacyjna","parameters":[{"name":"Zakres","range":"(5,0 – 48,0) h"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Stabilność oksydacyjna\nZakres (5,0 – 48,0) h\nMetoda konduktometryczna","reference":"PN-EN 15751:2014-05","norm_bases":["PN-EN 15751:2014-05"],"lab_section":"Punkt Obsługi Laboratoryjnej w Ostrowie Wielkopolskim PP7/3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, biopaliwa ciekłe: olej napędowy z FAME Stabilność oksydacyjna\nZakres (5,0 – 48,0) h\nMetoda konduktometryczna PN-EN 15751:2014-05 Paliwa ciekle: olej napedowy, biopaliwa ciekle: olej napedowy z FAME Stabilnosc oksydacyjna\nZakres (5,0 – 48,0) h\nMetoda konduktometryczna PN-EN 15751:2014-05","categories":["petro"],"row_index":501,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb73b","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Pobieranie próbek ze zbiorników do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek ze zbiorników do badań chemicznych i fizycznych","reference":"PN-EN ISO 3170:2025-12 Z wyłączeniem 8.3.1.3 - 8.3.1.6, 8.3.1.8, 8.3.2, 8.7- 8.9, 9.8, 10.6, 10.7","norm_bases":["PN-EN ISO 3170:2025-12 Z wyłączeniem 8.3.1.3 - 8.3.1.6, 8.3.1.8, 8.3.2, 8.7- 8.9, 9.8, 10.6, 10.7"],"lab_section":"Punkt Obsługi Laboratoryjnej w Lublinie PP7/1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Pobieranie próbek ze zbiorników do badań chemicznych i fizycznych PN-EN ISO 3170:2025-12 Z wyłączeniem 8.3.1.3 - 8.3.1.6, 8.3.1.8, 8.3.2, 8.7- 8.9, 9.8, 10.6, 10.7 Paliwa ciekle: benzyna bezolowiowa, olej napedowy, olej opalowy lekki, biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Pobieranie probek ze zbiornikow do badan chemicznych i fizycznych PN-EN ISO 3170:2025-12 Z wylaczeniem 8.3.1.3 - 8.3.1.6, 8.3.1.8, 8.3.2, 8.7- 8.9, 9.8, 10.6, 10.7","categories":["petro"],"row_index":502,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb73c","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Liczba oktanowa LOM","parameters":[{"name":"Zakres","range":"80,0 – 90,0"}],"technique":"Metoda silnikowa","techniques":["Metoda silnikowa"],"computed":[],"activity":"Liczba oktanowa LOM\nZakres 80,0 – 90,0\nMetoda silnikowa","reference":"PN-EN ISO 5163:2014-08","norm_bases":["PN-EN ISO 5163:2014-08"],"lab_section":"Punkt Obsługi Laboratoryjnej w Lublinie PP7/1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Liczba oktanowa LOM\nZakres 80,0 – 90,0\nMetoda silnikowa PN-EN ISO 5163:2014-08 Paliwa ciekle: benzyna bezolowiowa Liczba oktanowa LOM\nZakres 80,0 – 90,0\nMetoda silnikowa PN-EN ISO 5163:2014-08","categories":["petro"],"row_index":503,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb73d","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Prężność par nasyconych powietrzem","parameters":[{"name":"Zakres","range":"(40,0 – 106,0) kPa"}],"technique":"Metoda mini Reid","techniques":["Metoda mini Reid"],"computed":[],"activity":"Prężność par nasyconych powietrzem\nZakres (40,0 – 106,0) kPa\nMetoda mini Reid","reference":"PN-EN 13016-1:2024-11","norm_bases":["PN-EN 13016-1:2024-11"],"lab_section":"Punkt Obsługi Laboratoryjnej w Lublinie PP7/1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Prężność par nasyconych powietrzem\nZakres (40,0 – 106,0) kPa\nMetoda mini Reid PN-EN 13016-1:2024-11 Paliwa ciekle: benzyna bezolowiowa Preznosc par nasyconych powietrzem\nZakres (40,0 – 106,0) kPa\nMetoda mini Reid PN-EN 13016-1:2024-11","categories":["petro","environment"],"row_index":504,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb73e","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Indeks lotności (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Indeks lotności (z obliczeń)","reference":"PN-EN 228+A1:2017-06 p. 5.5.2","norm_bases":["PN-EN 228+A1:2017-06 p. 5.5.2"],"lab_section":"Punkt Obsługi Laboratoryjnej w Lublinie PP7/1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Indeks lotności (z obliczeń) PN-EN 228+A1:2017-06 p. 5.5.2 Paliwa ciekle: benzyna bezolowiowa Indeks lotnosci (z obliczen) PN-EN 228+A1:2017-06 p. 5.5.2","categories":["petro"],"row_index":505,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb73f","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Zawartość siarki","parameters":[{"name":"Zakres","range":"(3,0 – 100) mg/kg"}],"technique":"Metoda fluorescencji w nadfiolecie","techniques":["Metoda fluorescencji w nadfiolecie"],"computed":[],"activity":"Zawartość siarki\nZakres (3,0 – 100) mg/kg\nMetoda fluorescencji w nadfiolecie","reference":"PN-EN ISO 20846:2020-03","norm_bases":["PN-EN ISO 20846:2020-03"],"lab_section":"Punkt Obsługi Laboratoryjnej w Lublinie PP7/1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Zawartość siarki\nZakres (3,0 – 100) mg/kg\nMetoda fluorescencji w nadfiolecie PN-EN ISO 20846:2020-03 Paliwa ciekle: benzyna bezolowiowa Zawartosc siarki\nZakres (3,0 – 100) mg/kg\nMetoda fluorescencji w nadfiolecie PN-EN ISO 20846:2020-03","categories":["petro"],"row_index":506,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb740","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Gęstość w temperaturze 15°C","parameters":[{"name":"Zakres","range":"(700,0 – 800,0) kg/m3"}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"computed":[],"activity":"Gęstość w temperaturze 15°C\nZakres (700,0 – 800,0) kg/m3\nMetoda oscylacyjna","reference":"PN-EN ISO 12185:2024-08","norm_bases":["PN-EN ISO 12185:2024-08"],"lab_section":"Punkt Obsługi Laboratoryjnej w Lublinie PP7/1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Gęstość w temperaturze 15°C\nZakres (700,0 – 800,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08 Paliwa ciekle: benzyna bezolowiowa Gestosc w temperaturze 15°C\nZakres (700,0 – 800,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08","categories":["petro"],"row_index":507,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb741","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Skład frakcyjny","parameters":[{"name":"Zakres","range":"(30,0 – 220,0) oC"}],"technique":"Metoda destylacyjna","techniques":["Metoda destylacyjna"],"computed":[],"activity":"Skład frakcyjny\nZakres (30,0 – 220,0) oC\nMetoda destylacyjna","reference":"PN-EN ISO 3405:2019-05","norm_bases":["PN-EN ISO 3405:2019-05"],"lab_section":"Punkt Obsługi Laboratoryjnej w Lublinie PP7/1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Skład frakcyjny\nZakres (30,0 – 220,0) oC\nMetoda destylacyjna PN-EN ISO 3405:2019-05 Paliwa ciekle: benzyna bezolowiowa Sklad frakcyjny\nZakres (30,0 – 220,0) oC\nMetoda destylacyjna PN-EN ISO 3405:2019-05","categories":["petro"],"row_index":508,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb742","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Zawartość tlenowych związków organicznych","parameters":[{"name":"Zakres","range":"(0,17 – 15,0) % (v/v)"},{"name":"Całkowita zawartość organicznie związanego tlenu (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość tlenowych związków organicznych\nZakres:\nZakres (0,17 – 15,0) % (v/v)\nCałkowita zawartość organicznie związanego tlenu (z obliczeń)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13132:2005","norm_bases":["PN-EN 13132:2005"],"lab_section":"Punkt Obsługi Laboratoryjnej w Lublinie PP7/1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Zawartość tlenowych związków organicznych\nZakres:\nZakres (0,17 – 15,0) % (v/v)\nCałkowita zawartość organicznie związanego tlenu (z obliczeń)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13132:2005 Paliwa ciekle: benzyna bezolowiowa Zawartosc tlenowych zwiazkow organicznych\nZakres:\nZakres (0,17 – 15,0) % (v/v)\nCalkowita zawartosc organicznie zwiazanego tlenu (z obliczen)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13132:2005","categories":["petro"],"row_index":509,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb743","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki","methodology":"Gęstość w temperaturze 15°C","parameters":[{"name":"Zakres","range":"(800,0 – 900,0) kg/m3"}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"computed":[],"activity":"Gęstość w temperaturze 15°C\nZakres (800,0 – 900,0) kg/m3\nMetoda oscylacyjna","reference":"PN-EN ISO 12185:2024-08","norm_bases":["PN-EN ISO 12185:2024-08"],"lab_section":"Punkt Obsługi Laboratoryjnej w Lublinie PP7/1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki Gęstość w temperaturze 15°C\nZakres (800,0 – 900,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08 Paliwa ciekle: olej napedowy, olej opalowy lekki Gestosc w temperaturze 15°C\nZakres (800,0 – 900,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08","categories":["petro"],"row_index":510,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb744","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki","methodology":"Skład frakcyjny","parameters":[{"name":"Zakres","range":"(150,0 – 370,0) oC"}],"technique":"Metoda destylacyjna","techniques":["Metoda destylacyjna"],"computed":[],"activity":"Skład frakcyjny\nZakres (150,0 – 370,0) oC\nMetoda destylacyjna","reference":"PN-EN ISO 3405:2019-05","norm_bases":["PN-EN ISO 3405:2019-05"],"lab_section":"Punkt Obsługi Laboratoryjnej w Lublinie PP7/1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki Skład frakcyjny\nZakres (150,0 – 370,0) oC\nMetoda destylacyjna PN-EN ISO 3405:2019-05 Paliwa ciekle: olej napedowy, olej opalowy lekki Sklad frakcyjny\nZakres (150,0 – 370,0) oC\nMetoda destylacyjna PN-EN ISO 3405:2019-05","categories":["petro"],"row_index":511,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb745","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki","methodology":"Zawartość zanieczyszczeń","parameters":[{"name":"Zakres","range":"(12,0 – 26,0) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość zanieczyszczeń\nZakres (12,0 – 26,0) mg/kg\nMetoda wagowa","reference":"PN-EN 12662-1:2024-11","norm_bases":["PN-EN 12662-1:2024-11"],"lab_section":"Punkt Obsługi Laboratoryjnej w Lublinie PP7/1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki Zawartość zanieczyszczeń\nZakres (12,0 – 26,0) mg/kg\nMetoda wagowa PN-EN 12662-1:2024-11 Paliwa ciekle: olej napedowy, olej opalowy lekki Zawartosc zanieczyszczen\nZakres (12,0 – 26,0) mg/kg\nMetoda wagowa PN-EN 12662-1:2024-11","categories":["petro"],"row_index":512,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb746","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki","methodology":"Zawartość wody","parameters":[{"name":"Zakres","range":"(0,003 – 0,100) %(m/m)"}],"technique":"Metoda miareczkowania kulometrycznego","techniques":["Metoda miareczkowania kulometrycznego"],"computed":[],"activity":"Zawartość wody\nZakres (0,003 – 0,100) %(m/m)\nMetoda miareczkowania kulometrycznego","reference":"PN-EN ISO 12937:2005+Ap1:2021-11","norm_bases":["PN-EN ISO 12937:2005+Ap1:2021-11"],"lab_section":"Punkt Obsługi Laboratoryjnej w Lublinie PP7/1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki Zawartość wody\nZakres (0,003 – 0,100) %(m/m)\nMetoda miareczkowania kulometrycznego PN-EN ISO 12937:2005+Ap1:2021-11 Paliwa ciekle: olej napedowy, olej opalowy lekki Zawartosc wody\nZakres (0,003 – 0,100) %(m/m)\nMetoda miareczkowania kulometrycznego PN-EN ISO 12937:2005+Ap1:2021-11","categories":["petro","water"],"row_index":513,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb747","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki","methodology":"Temperatura zapłonu","parameters":[{"name":"Zakres","range":"(40,0 – 100,0) oC"}],"technique":"Metoda zamkniętego tygla Pensky’ego-Martensa","techniques":["Metoda zamkniętego tygla Pensky’ego-Martensa"],"computed":[],"activity":"Temperatura zapłonu\nZakres (40,0 – 100,0) oC\nMetoda zamkniętego tygla Pensky’ego-Martensa","reference":"PN-EN ISO 2719:2016-08+A1:2021-06","norm_bases":["PN-EN ISO 2719:2016-08+A1:2021-06"],"lab_section":"Punkt Obsługi Laboratoryjnej w Lublinie PP7/1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki Temperatura zapłonu\nZakres (40,0 – 100,0) oC\nMetoda zamkniętego tygla Pensky’ego-Martensa PN-EN ISO 2719:2016-08+A1:2021-06 Paliwa ciekle: olej napedowy, olej opalowy lekki Temperatura zaplonu\nZakres (40,0 – 100,0) oC\nMetoda zamknietego tygla Pensky’ego-Martensa PN-EN ISO 2719:2016-08+A1:2021-06","categories":["petro"],"row_index":514,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb748","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki","methodology":"Zawartość siarki","parameters":[{"name":"Zakres","range":"(3,0 – 100) mg/kg"}],"technique":"Metoda fluorescencji w nadfiolecie","techniques":["Metoda fluorescencji w nadfiolecie"],"computed":[],"activity":"Zawartość siarki\nZakres (3,0 – 100) mg/kg\nMetoda fluorescencji w nadfiolecie","reference":"PN-EN ISO 20846:2020-03","norm_bases":["PN-EN ISO 20846:2020-03"],"lab_section":"Punkt Obsługi Laboratoryjnej w Lublinie PP7/1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki Zawartość siarki\nZakres (3,0 – 100) mg/kg\nMetoda fluorescencji w nadfiolecie PN-EN ISO 20846:2020-03 Paliwa ciekle: olej napedowy, olej opalowy lekki Zawartosc siarki\nZakres (3,0 – 100) mg/kg\nMetoda fluorescencji w nadfiolecie PN-EN ISO 20846:2020-03","categories":["petro"],"row_index":515,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb749","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy","methodology":"Indeks cetanowy (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Indeks cetanowy (z obliczeń)","reference":"PN-EN ISO 4264:2018-08","norm_bases":["PN-EN ISO 4264:2018-08"],"lab_section":"Punkt Obsługi Laboratoryjnej w Lublinie PP7/1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy Indeks cetanowy (z obliczeń) PN-EN ISO 4264:2018-08 Paliwa ciekle: olej napedowy Indeks cetanowy (z obliczen) PN-EN ISO 4264:2018-08","categories":["petro"],"row_index":516,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb74a","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy","methodology":"Temperatura zablokowania zimnego filtra","parameters":[{"name":"[(- 33)","range":"(+5)] oC"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Temperatura zablokowania zimnego filtra\n[(- 33) (+5)] oC\nMetoda optyczna","reference":"PN-EN 116:2015-09","norm_bases":["PN-EN 116:2015-09"],"lab_section":"Punkt Obsługi Laboratoryjnej w Lublinie PP7/1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy Temperatura zablokowania zimnego filtra\n[(- 33) (+5)] oC\nMetoda optyczna PN-EN 116:2015-09 Paliwa ciekle: olej napedowy Temperatura zablokowania zimnego filtra\n[(- 33) (+5)] oC\nMetoda optyczna PN-EN 116:2015-09","categories":["petro"],"row_index":517,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb74b","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy","methodology":"Zawartość estrów metylowych kwasów tłuszczowych (FAME)","parameters":[{"name":"Zakres","range":"(3,0 – 10,0) %(v/v)"}],"technique":"Metoda spektrometrii w zakresie podczerwieni IR","techniques":["Metoda spektrometrii w zakresie podczerwieni IR"],"computed":[],"activity":"Zawartość estrów metylowych kwasów tłuszczowych (FAME)\nZakres (3,0 – 10,0) %(v/v)\nMetoda spektrometrii w zakresie podczerwieni IR","reference":"PN-EN 14078:2014-06","norm_bases":["PN-EN 14078:2014-06"],"lab_section":"Punkt Obsługi Laboratoryjnej w Lublinie PP7/1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy Zawartość estrów metylowych kwasów tłuszczowych (FAME)\nZakres (3,0 – 10,0) %(v/v)\nMetoda spektrometrii w zakresie podczerwieni IR PN-EN 14078:2014-06 Paliwa ciekle: olej napedowy Zawartosc estrow metylowych kwasow tluszczowych (FAME)\nZakres (3,0 – 10,0) %(v/v)\nMetoda spektrometrii w zakresie podczerwieni IR PN-EN 14078:2014-06","categories":["petro"],"row_index":518,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb74c","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Gęstość w temperaturze 15°C","parameters":[{"name":"Zakres","range":"(860,0 – 900,0) kg/m3"}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"computed":[],"activity":"Gęstość w temperaturze 15°C\nZakres (860,0 – 900,0) kg/m3\nMetoda oscylacyjna","reference":"PN-EN ISO 12185:2024-08","norm_bases":["PN-EN ISO 12185:2024-08"],"lab_section":"Punkt Obsługi Laboratoryjnej w Lublinie PP7/1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Gęstość w temperaturze 15°C\nZakres (860,0 – 900,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Gestosc w temperaturze 15°C\nZakres (860,0 – 900,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08","categories":["petro"],"row_index":519,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb74d","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość wody","parameters":[{"name":"Zakres","range":"(0,003 – 0,100) %(m/m)"}],"technique":"Metoda miareczkowania kulometrycznego","techniques":["Metoda miareczkowania kulometrycznego"],"computed":[],"activity":"Zawartość wody\nZakres (0,003 – 0,100) %(m/m)\nMetoda miareczkowania kulometrycznego","reference":"PN-EN ISO 12937:2005+Ap1:2021-11","norm_bases":["PN-EN ISO 12937:2005+Ap1:2021-11"],"lab_section":"Punkt Obsługi Laboratoryjnej w Lublinie PP7/1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Zawartość wody\nZakres (0,003 – 0,100) %(m/m)\nMetoda miareczkowania kulometrycznego PN-EN ISO 12937:2005+Ap1:2021-11 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Zawartosc wody\nZakres (0,003 – 0,100) %(m/m)\nMetoda miareczkowania kulometrycznego PN-EN ISO 12937:2005+Ap1:2021-11","categories":["petro","water"],"row_index":520,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb74e","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Temperatura zablokowania zimnego filtra","parameters":[{"name":"[(- 25)","range":"(-5)] oC"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Temperatura zablokowania zimnego filtra\n[(- 25) (-5)] oC\nMetoda optyczna","reference":"PN-EN 116:2015-09","norm_bases":["PN-EN 116:2015-09"],"lab_section":"Punkt Obsługi Laboratoryjnej w Lublinie PP7/1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Temperatura zablokowania zimnego filtra\n[(- 25) (-5)] oC\nMetoda optyczna PN-EN 116:2015-09 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Temperatura zablokowania zimnego filtra\n[(- 25) (-5)] oC\nMetoda optyczna PN-EN 116:2015-09","categories":["petro"],"row_index":521,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb74f","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Skłonność do blokowania filtra po wychładzaniu","parameters":[{"name":"Zakres","range":"(30 – 360) s"}],"technique":"Metoda filtracji po wychłodzeniu","techniques":["Metoda filtracji po wychłodzeniu"],"computed":[],"activity":"Skłonność do blokowania filtra po wychładzaniu\nZakres (30 – 360) s\nMetoda filtracji po wychłodzeniu","reference":"ASTM D 7501-22","norm_bases":["ASTM D 7501-22"],"lab_section":"Punkt Obsługi Laboratoryjnej w Lublinie PP7/1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Skłonność do blokowania filtra po wychładzaniu\nZakres (30 – 360) s\nMetoda filtracji po wychłodzeniu ASTM D 7501-22 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Sklonnosc do blokowania filtra po wychladzaniu\nZakres (30 – 360) s\nMetoda filtracji po wychlodzeniu ASTM D 7501-22","categories":["petro"],"row_index":522,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb750","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość zanieczyszczeń","parameters":[{"name":"Zakres","range":"(5,0 – 27,0) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość zanieczyszczeń\nZakres (5,0 – 27,0) mg/kg\nMetoda wagowa","reference":"PN-EN 12662-2:2024-11","norm_bases":["PN-EN 12662-2:2024-11"],"lab_section":"Punkt Obsługi Laboratoryjnej w Lublinie PP7/1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Zawartość zanieczyszczeń\nZakres (5,0 – 27,0) mg/kg\nMetoda wagowa PN-EN 12662-2:2024-11 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Zawartosc zanieczyszczen\nZakres (5,0 – 27,0) mg/kg\nMetoda wagowa PN-EN 12662-2:2024-11","categories":["petro"],"row_index":523,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb751","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, olej opałowy lekki, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Pobieranie próbek ze zbiornika do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek ze zbiornika do badań chemicznych i fizycznych","reference":"PN-EN ISO 3170:2025-12 z wyłączeniem 8.3.1.3 - 8.3.1.6, 8.3.1.8, 8.3.2, 8.7 - 8.9, 9.8, 10.6, 10.7","norm_bases":["PN-EN ISO 3170:2025-12 z wyłączeniem 8.3.1.3 - 8.3.1.6, 8.3.1.8, 8.3.2, 8.7 - 8.9, 9.8, 10.6, 10.7"],"lab_section":"Punkt Obsługi Laboratoryjnej w Olsztynie PP7/2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, olej opałowy lekki, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Pobieranie próbek ze zbiornika do badań chemicznych i fizycznych PN-EN ISO 3170:2025-12 z wyłączeniem 8.3.1.3 - 8.3.1.6, 8.3.1.8, 8.3.2, 8.7 - 8.9, 9.8, 10.6, 10.7 Paliwa ciekle: olej napedowy, benzyna bezolowiowa, olej opalowy lekki, biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Pobieranie probek ze zbiornika do badan chemicznych i fizycznych PN-EN ISO 3170:2025-12 z wylaczeniem 8.3.1.3 - 8.3.1.6, 8.3.1.8, 8.3.2, 8.7 - 8.9, 9.8, 10.6, 10.7","categories":["petro"],"row_index":524,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb752","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, olej opałowy lekki","methodology":"Zawartość siarki","parameters":[{"name":"Zakres","range":"(3,0 – 50) mg/kg"}],"technique":"Metoda fluorescencji w nadfiolecie","techniques":["Metoda fluorescencji w nadfiolecie"],"computed":[],"activity":"Zawartość siarki\nZakres (3,0 – 50) mg/kg\nMetoda fluorescencji w nadfiolecie","reference":"PN-EN ISO 20846:2020-03","norm_bases":["PN-EN ISO 20846:2020-03"],"lab_section":"Punkt Obsługi Laboratoryjnej w Olsztynie PP7/2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, olej opałowy lekki Zawartość siarki\nZakres (3,0 – 50) mg/kg\nMetoda fluorescencji w nadfiolecie PN-EN ISO 20846:2020-03 Paliwa ciekle: olej napedowy, benzyna bezolowiowa, olej opalowy lekki Zawartosc siarki\nZakres (3,0 – 50) mg/kg\nMetoda fluorescencji w nadfiolecie PN-EN ISO 20846:2020-03","categories":["petro"],"row_index":525,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb753","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, olej opałowy lekki","methodology":"Gęstość w temperaturze 15°C","parameters":[{"name":"Zakres","range":"(700,0 – 900,0) kg/m3"}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"computed":[],"activity":"Gęstość w temperaturze 15°C\nZakres (700,0 – 900,0) kg/m3\nMetoda oscylacyjna","reference":"PN-EN ISO 12185:2024-08","norm_bases":["PN-EN ISO 12185:2024-08"],"lab_section":"Punkt Obsługi Laboratoryjnej w Olsztynie PP7/2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, olej opałowy lekki Gęstość w temperaturze 15°C\nZakres (700,0 – 900,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08 Paliwa ciekle: olej napedowy, benzyna bezolowiowa, olej opalowy lekki Gestosc w temperaturze 15°C\nZakres (700,0 – 900,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08","categories":["petro"],"row_index":526,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb754","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, olej opałowy lekki","methodology":"Skład frakcyjny","parameters":[{"name":"Zakres","range":"(30,0 – 370,0) oC"}],"technique":"Metoda destylacyjna","techniques":["Metoda destylacyjna"],"computed":[],"activity":"Skład frakcyjny\nZakres (30,0 – 370,0) oC\nMetoda destylacyjna","reference":"PN-EN ISO 3405:2019-05","norm_bases":["PN-EN ISO 3405:2019-05"],"lab_section":"Punkt Obsługi Laboratoryjnej w Olsztynie PP7/2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, olej opałowy lekki Skład frakcyjny\nZakres (30,0 – 370,0) oC\nMetoda destylacyjna PN-EN ISO 3405:2019-05 Paliwa ciekle: olej napedowy, benzyna bezolowiowa, olej opalowy lekki Sklad frakcyjny\nZakres (30,0 – 370,0) oC\nMetoda destylacyjna PN-EN ISO 3405:2019-05","categories":["petro"],"row_index":527,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb755","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy","methodology":"Temperatura zablokowania zimnego filtra","parameters":[{"name":"[","range":"(-40) – (0,0)]°C"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Temperatura zablokowania zimnego filtra\n[ (-40) – (0,0)]°C\nMetoda optyczna","reference":"PN-EN 116:2015-09","norm_bases":["PN-EN 116:2015-09"],"lab_section":"Punkt Obsługi Laboratoryjnej w Olsztynie PP7/2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy Temperatura zablokowania zimnego filtra\n[ (-40) – (0,0)]°C\nMetoda optyczna PN-EN 116:2015-09 Paliwa ciekle: olej napedowy Temperatura zablokowania zimnego filtra\n[ (-40) – (0,0)]°C\nMetoda optyczna PN-EN 116:2015-09","categories":["petro"],"row_index":528,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb756","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy","methodology":"Indeks cetanowy (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Indeks cetanowy (z obliczeń)","reference":"PN-EN ISO 4264:2018-08","norm_bases":["PN-EN ISO 4264:2018-08"],"lab_section":"Punkt Obsługi Laboratoryjnej w Olsztynie PP7/2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy Indeks cetanowy (z obliczeń) PN-EN ISO 4264:2018-08 Paliwa ciekle: olej napedowy Indeks cetanowy (z obliczen) PN-EN ISO 4264:2018-08","categories":["petro"],"row_index":529,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb757","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy","methodology":"Zawartość zanieczyszczeń","parameters":[{"name":"Zakres","range":"(12,0 – 26,0) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość zanieczyszczeń\nZakres (12,0 – 26,0) mg/kg\nMetoda wagowa","reference":"PN-EN 12662-1:2024-11","norm_bases":["PN-EN 12662-1:2024-11"],"lab_section":"Punkt Obsługi Laboratoryjnej w Olsztynie PP7/2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy Zawartość zanieczyszczeń\nZakres (12,0 – 26,0) mg/kg\nMetoda wagowa PN-EN 12662-1:2024-11 Paliwa ciekle: olej napedowy Zawartosc zanieczyszczen\nZakres (12,0 – 26,0) mg/kg\nMetoda wagowa PN-EN 12662-1:2024-11","categories":["petro"],"row_index":530,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb758","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy","methodology":"Temperatura mętnienia","parameters":[{"name":"[(- 20,0)","range":"(0,0)] oC"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Temperatura mętnienia\n[(- 20,0) (0,0)] oC\nMetoda optyczna","reference":"ASTM D 5772-21","norm_bases":["ASTM D 5772-21"],"lab_section":"Punkt Obsługi Laboratoryjnej w Olsztynie PP7/2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy Temperatura mętnienia\n[(- 20,0) (0,0)] oC\nMetoda optyczna ASTM D 5772-21 Paliwa ciekle: olej napedowy Temperatura metnienia\n[(- 20,0) (0,0)] oC\nMetoda optyczna ASTM D 5772-21","categories":["petro"],"row_index":531,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb759","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki","methodology":"Temperatura zapłonu","parameters":[{"name":"Zakres","range":"(40,0 – 90,0) oC"}],"technique":"Metoda zamkniętego tygla Pensky’ego-Martensa","techniques":["Metoda zamkniętego tygla Pensky’ego-Martensa"],"computed":[],"activity":"Temperatura zapłonu\nZakres (40,0 – 90,0) oC\nMetoda zamkniętego tygla Pensky’ego-Martensa","reference":"PN-EN ISO 2719:2016-08+A1:2021-06","norm_bases":["PN-EN ISO 2719:2016-08+A1:2021-06"],"lab_section":"Punkt Obsługi Laboratoryjnej w Olsztynie PP7/2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki Temperatura zapłonu\nZakres (40,0 – 90,0) oC\nMetoda zamkniętego tygla Pensky’ego-Martensa PN-EN ISO 2719:2016-08+A1:2021-06 Paliwa ciekle: olej napedowy, olej opalowy lekki Temperatura zaplonu\nZakres (40,0 – 90,0) oC\nMetoda zamknietego tygla Pensky’ego-Martensa PN-EN ISO 2719:2016-08+A1:2021-06","categories":["petro"],"row_index":532,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb75a","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki","methodology":"Zawartość wody","parameters":[{"name":"Zakres","range":"(30 – 1000) mg/kg"}],"technique":"Metoda miareczkowania kulometrycznego","techniques":["Metoda miareczkowania kulometrycznego"],"computed":[],"activity":"Zawartość wody\nZakres (30 – 1000) mg/kg\nMetoda miareczkowania kulometrycznego","reference":"PN-EN ISO 12937:2005+Ap1:2021-11","norm_bases":["PN-EN ISO 12937:2005+Ap1:2021-11"],"lab_section":"Punkt Obsługi Laboratoryjnej w Olsztynie PP7/2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki Zawartość wody\nZakres (30 – 1000) mg/kg\nMetoda miareczkowania kulometrycznego PN-EN ISO 12937:2005+Ap1:2021-11 Paliwa ciekle: olej napedowy, olej opalowy lekki Zawartosc wody\nZakres (30 – 1000) mg/kg\nMetoda miareczkowania kulometrycznego PN-EN ISO 12937:2005+Ap1:2021-11","categories":["petro","water"],"row_index":533,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb75b","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Zawartość tlenowych związków organicznych","parameters":[{"name":"Zakres","range":"(0,17 – 15,0) %(v/v)"},{"name":"Całkowita zawartość organicznie związanego tlenu (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość tlenowych związków organicznych\nZakres:\nZakres (0,17 – 15,0) %(v/v)\nCałkowita zawartość organicznie związanego tlenu (z obliczeń)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13132:2005","norm_bases":["PN-EN 13132:2005"],"lab_section":"Punkt Obsługi Laboratoryjnej w Olsztynie PP7/2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Zawartość tlenowych związków organicznych\nZakres:\nZakres (0,17 – 15,0) %(v/v)\nCałkowita zawartość organicznie związanego tlenu (z obliczeń)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13132:2005 Paliwa ciekle: benzyna bezolowiowa Zawartosc tlenowych zwiazkow organicznych\nZakres:\nZakres (0,17 – 15,0) %(v/v)\nCalkowita zawartosc organicznie zwiazanego tlenu (z obliczen)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13132:2005","categories":["petro"],"row_index":534,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb75c","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Prężność par nasyconych powietrzem","parameters":[{"name":"Zakres","range":"(40,0 – 106,0) kPa"}],"technique":"Metoda mini Reid","techniques":["Metoda mini Reid"],"computed":[],"activity":"Prężność par nasyconych powietrzem\nZakres (40,0 – 106,0) kPa\nMetoda mini Reid","reference":"PN-EN 13016-1:2024-11","norm_bases":["PN-EN 13016-1:2024-11"],"lab_section":"Punkt Obsługi Laboratoryjnej w Olsztynie PP7/2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Prężność par nasyconych powietrzem\nZakres (40,0 – 106,0) kPa\nMetoda mini Reid PN-EN 13016-1:2024-11 Paliwa ciekle: benzyna bezolowiowa Preznosc par nasyconych powietrzem\nZakres (40,0 – 106,0) kPa\nMetoda mini Reid PN-EN 13016-1:2024-11","categories":["petro","environment"],"row_index":535,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb75d","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Indeks lotności (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Indeks lotności (z obliczeń)","reference":"PN-EN 228+A1:2017-06 p. 5.5.2","norm_bases":["PN-EN 228+A1:2017-06 p. 5.5.2"],"lab_section":"Punkt Obsługi Laboratoryjnej w Olsztynie PP7/2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Indeks lotności (z obliczeń) PN-EN 228+A1:2017-06 p. 5.5.2 Paliwa ciekle: benzyna bezolowiowa Indeks lotnosci (z obliczen) PN-EN 228+A1:2017-06 p. 5.5.2","categories":["petro"],"row_index":536,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb75e","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Liczba oktanowa LOM","parameters":[{"name":"Zakres","range":"80,0 – 90,0"}],"technique":"Metoda silnikowa","techniques":["Metoda silnikowa"],"computed":[],"activity":"Liczba oktanowa LOM\nZakres 80,0 – 90,0\nMetoda silnikowa","reference":"PN-EN ISO 5163:2014-08","norm_bases":["PN-EN ISO 5163:2014-08"],"lab_section":"Punkt Obsługi Laboratoryjnej w Olsztynie PP7/2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Liczba oktanowa LOM\nZakres 80,0 – 90,0\nMetoda silnikowa PN-EN ISO 5163:2014-08 Paliwa ciekle: benzyna bezolowiowa Liczba oktanowa LOM\nZakres 80,0 – 90,0\nMetoda silnikowa PN-EN ISO 5163:2014-08","categories":["petro"],"row_index":537,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb75f","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, biopaliwa ciekłe: olej napędowy z FAME","methodology":"Zawartość estrów metylowych kwasów tłuszczowych","parameters":[{"name":"Zakres","range":"(3,0 – 20,0) %(v/v)"}],"technique":"Metoda spektrometrii w zakresie podczerwieni IR","techniques":["Metoda spektrometrii w zakresie podczerwieni IR"],"computed":[],"activity":"Zawartość estrów metylowych kwasów tłuszczowych\nZakres (3,0 – 20,0) %(v/v)\nMetoda spektrometrii w zakresie podczerwieni IR","reference":"PN-EN 14078:2014-06","norm_bases":["PN-EN 14078:2014-06"],"lab_section":"Punkt Obsługi Laboratoryjnej w Olsztynie PP7/2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, biopaliwa ciekłe: olej napędowy z FAME Zawartość estrów metylowych kwasów tłuszczowych\nZakres (3,0 – 20,0) %(v/v)\nMetoda spektrometrii w zakresie podczerwieni IR PN-EN 14078:2014-06 Paliwa ciekle: olej napedowy, biopaliwa ciekle: olej napedowy z FAME Zawartosc estrow metylowych kwasow tluszczowych\nZakres (3,0 – 20,0) %(v/v)\nMetoda spektrometrii w zakresie podczerwieni IR PN-EN 14078:2014-06","categories":["petro"],"row_index":538,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb760","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Gęstość w temperaturze 15°C","parameters":[{"name":"Zakres","range":"(800,0 – 900,0) kg/m3"}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"computed":[],"activity":"Gęstość w temperaturze 15°C\nZakres (800,0 – 900,0) kg/m3\nMetoda oscylacyjna","reference":"PN-EN ISO 12185:2024-08","norm_bases":["PN-EN ISO 12185:2024-08"],"lab_section":"Punkt Obsługi Laboratoryjnej w Olsztynie PP7/2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Gęstość w temperaturze 15°C\nZakres (800,0 – 900,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Gestosc w temperaturze 15°C\nZakres (800,0 – 900,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08","categories":["petro"],"row_index":539,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb761","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość wody","parameters":[{"name":"Zakres","range":"(30 – 1000) mg/kg"}],"technique":"Metoda miareczkowania kulometrycznego","techniques":["Metoda miareczkowania kulometrycznego"],"computed":[],"activity":"Zawartość wody\nZakres (30 – 1000) mg/kg\nMetoda miareczkowania kulometrycznego","reference":"PN-EN ISO 12937:2005+Ap1:2021-11","norm_bases":["PN-EN ISO 12937:2005+Ap1:2021-11"],"lab_section":"Punkt Obsługi Laboratoryjnej w Olsztynie PP7/2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Zawartość wody\nZakres (30 – 1000) mg/kg\nMetoda miareczkowania kulometrycznego PN-EN ISO 12937:2005+Ap1:2021-11 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Zawartosc wody\nZakres (30 – 1000) mg/kg\nMetoda miareczkowania kulometrycznego PN-EN ISO 12937:2005+Ap1:2021-11","categories":["petro","water"],"row_index":540,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb762","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Temperatura mętnienia","parameters":[{"name":"[(- 20,0)","range":"(0,0)] oC"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Temperatura mętnienia\n[(- 20,0) (0,0)] oC\nMetoda optyczna","reference":"ASTM D 5772-21","norm_bases":["ASTM D 5772-21"],"lab_section":"Punkt Obsługi Laboratoryjnej w Olsztynie PP7/2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Temperatura mętnienia\n[(- 20,0) (0,0)] oC\nMetoda optyczna ASTM D 5772-21 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Temperatura metnienia\n[(- 20,0) (0,0)] oC\nMetoda optyczna ASTM D 5772-21","categories":["petro"],"row_index":541,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb763","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Temperatura zablokowania zimnego filtra","parameters":[{"name":"[(-40)","range":"(0,0)] °C"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Temperatura zablokowania zimnego filtra\n[(-40) (0,0)] °C\nMetoda optyczna","reference":"PN-EN 116:2015-09","norm_bases":["PN-EN 116:2015-09"],"lab_section":"Punkt Obsługi Laboratoryjnej w Olsztynie PP7/2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Temperatura zablokowania zimnego filtra\n[(-40) (0,0)] °C\nMetoda optyczna PN-EN 116:2015-09 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Temperatura zablokowania zimnego filtra\n[(-40) (0,0)] °C\nMetoda optyczna PN-EN 116:2015-09","categories":["petro"],"row_index":542,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb764","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Skłonność do blokowania filtra po wychładzaniu","parameters":[{"name":"Zakres","range":"(50,0 – 360) s"}],"technique":"Metoda filtracji po wychłodzeniu","techniques":["Metoda filtracji po wychłodzeniu"],"computed":[],"activity":"Skłonność do blokowania filtra po wychładzaniu\nZakres (50,0 – 360) s\nMetoda filtracji po wychłodzeniu","reference":"ASTM D 7501-22","norm_bases":["ASTM D 7501-22"],"lab_section":"Punkt Obsługi Laboratoryjnej w Olsztynie PP7/2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Skłonność do blokowania filtra po wychładzaniu\nZakres (50,0 – 360) s\nMetoda filtracji po wychłodzeniu ASTM D 7501-22 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Sklonnosc do blokowania filtra po wychladzaniu\nZakres (50,0 – 360) s\nMetoda filtracji po wychlodzeniu ASTM D 7501-22","categories":["petro"],"row_index":543,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb765","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość zanieczyszczeń","parameters":[{"name":"Zakres","range":"(5,0 – 27,0) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość zanieczyszczeń\nZakres (5,0 – 27,0) mg/kg\nMetoda wagowa","reference":"PN-EN 12662-2:2024-11","norm_bases":["PN-EN 12662-2:2024-11"],"lab_section":"Punkt Obsługi Laboratoryjnej w Olsztynie PP7/2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Zawartość zanieczyszczeń\nZakres (5,0 – 27,0) mg/kg\nMetoda wagowa PN-EN 12662-2:2024-11 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Zawartosc zanieczyszczen\nZakres (5,0 – 27,0) mg/kg\nMetoda wagowa PN-EN 12662-2:2024-11","categories":["petro"],"row_index":544,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb766","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME), bioetanol","methodology":"Pobieranie próbek punktowych ze zbiorników do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek punktowych ze zbiorników do badań chemicznych i fizycznych","reference":"PN-EN ISO 3170:2025-12 z wyłączeniem 8.3.1.3, 8.3.1.5, 8.3.1.6, 8.3.1.8, 8.3.2, 8.7-8.9, 9.8, 10.6, 10.7","norm_bases":["PN-EN ISO 3170:2025-12 z wyłączeniem 8.3.1.3, 8.3.1.5, 8.3.1.6, 8.3.1.8, 8.3.2, 8.7-8.9, 9.8, 10.6, 10.7"],"lab_section":"Punkt Obsługi Laboratoryjnej w Warszawie PP7/4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME), bioetanol Pobieranie próbek punktowych ze zbiorników do badań chemicznych i fizycznych PN-EN ISO 3170:2025-12 z wyłączeniem 8.3.1.3, 8.3.1.5, 8.3.1.6, 8.3.1.8, 8.3.2, 8.7-8.9, 9.8, 10.6, 10.7 Paliwa ciekle: benzyna bezolowiowa, olej napedowy biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME), bioetanol Pobieranie probek punktowych ze zbiornikow do badan chemicznych i fizycznych PN-EN ISO 3170:2025-12 z wylaczeniem 8.3.1.3, 8.3.1.5, 8.3.1.6, 8.3.1.8, 8.3.2, 8.7-8.9, 9.8, 10.6, 10.7","categories":["petro"],"row_index":545,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb767","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Prężność par nasyconych powietrzem","parameters":[{"name":"Zakres","range":"(40,0 – 106,0) kPa"}],"technique":"Metoda mini Reid","techniques":["Metoda mini Reid"],"computed":[],"activity":"Prężność par nasyconych powietrzem\nZakres (40,0 – 106,0) kPa\nMetoda mini Reid","reference":"PN-EN 13016-1:2024-11","norm_bases":["PN-EN 13016-1:2024-11"],"lab_section":"Punkt Obsługi Laboratoryjnej w Warszawie PP7/4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Prężność par nasyconych powietrzem\nZakres (40,0 – 106,0) kPa\nMetoda mini Reid PN-EN 13016-1:2024-11 Paliwa ciekle: benzyna bezolowiowa Preznosc par nasyconych powietrzem\nZakres (40,0 – 106,0) kPa\nMetoda mini Reid PN-EN 13016-1:2024-11","categories":["petro","environment"],"row_index":546,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb768","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Zawartość tlenowych związków organicznych","parameters":[{"name":"Zakres","range":"(0,17 – 15,0) %(v/v)"},{"name":"Całkowita zawartość organicznie związanego tlenu (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość tlenowych związków organicznych\nZakres:\nZakres (0,17 – 15,0) %(v/v)\nCałkowita zawartość organicznie związanego tlenu (z obliczeń)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13132:2005","norm_bases":["PN-EN 13132:2005"],"lab_section":"Punkt Obsługi Laboratoryjnej w Warszawie PP7/4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Zawartość tlenowych związków organicznych\nZakres:\nZakres (0,17 – 15,0) %(v/v)\nCałkowita zawartość organicznie związanego tlenu (z obliczeń)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13132:2005 Paliwa ciekle: benzyna bezolowiowa Zawartosc tlenowych zwiazkow organicznych\nZakres:\nZakres (0,17 – 15,0) %(v/v)\nCalkowita zawartosc organicznie zwiazanego tlenu (z obliczen)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13132:2005","categories":["petro"],"row_index":547,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb769","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Indeks lotności (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Indeks lotności (z obliczeń)","reference":"PN-EN 228+A1:2017-06 p. 5.5.2","norm_bases":["PN-EN 228+A1:2017-06 p. 5.5.2"],"lab_section":"Punkt Obsługi Laboratoryjnej w Warszawie PP7/4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Indeks lotności (z obliczeń) PN-EN 228+A1:2017-06 p. 5.5.2 Paliwa ciekle: benzyna bezolowiowa Indeks lotnosci (z obliczen) PN-EN 228+A1:2017-06 p. 5.5.2","categories":["petro"],"row_index":548,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb76a","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Liczba oktanowa LOM","parameters":[{"name":"Zakres","range":"80,0 – 90,0"}],"technique":"Metoda silnikowa","techniques":["Metoda silnikowa"],"computed":[],"activity":"Liczba oktanowa LOM\nZakres 80,0 – 90,0\nMetoda silnikowa","reference":"PN-EN ISO 5163:2014-08","norm_bases":["PN-EN ISO 5163:2014-08"],"lab_section":"Punkt Obsługi Laboratoryjnej w Warszawie PP7/4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Liczba oktanowa LOM\nZakres 80,0 – 90,0\nMetoda silnikowa PN-EN ISO 5163:2014-08 Paliwa ciekle: benzyna bezolowiowa Liczba oktanowa LOM\nZakres 80,0 – 90,0\nMetoda silnikowa PN-EN ISO 5163:2014-08","categories":["petro"],"row_index":549,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb76b","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki","methodology":"Zawartość siarki","parameters":[{"name":"Zakres","range":"(3,0 – 60,0) mg/kg"}],"technique":"Metoda fluorescencji w nadfiolecie","techniques":["Metoda fluorescencji w nadfiolecie"],"computed":[],"activity":"Zawartość siarki\nZakres (3,0 – 60,0) mg/kg\nMetoda fluorescencji w nadfiolecie","reference":"PN-EN ISO 20846:2020-03","norm_bases":["PN-EN ISO 20846:2020-03"],"lab_section":"Punkt Obsługi Laboratoryjnej w Warszawie PP7/4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki Zawartość siarki\nZakres (3,0 – 60,0) mg/kg\nMetoda fluorescencji w nadfiolecie PN-EN ISO 20846:2020-03 Paliwa ciekle: benzyna bezolowiowa, olej napedowy, olej opalowy lekki Zawartosc siarki\nZakres (3,0 – 60,0) mg/kg\nMetoda fluorescencji w nadfiolecie PN-EN ISO 20846:2020-03","categories":["petro"],"row_index":550,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb76c","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki","methodology":"Gęstość w temperaturze 15°C","parameters":[{"name":"Zakres","range":"(700,0 – 900,0) kg/m3"}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"computed":[],"activity":"Gęstość w temperaturze 15°C\nZakres (700,0 – 900,0) kg/m3\nMetoda oscylacyjna","reference":"PN-EN ISO 12185:2024-08","norm_bases":["PN-EN ISO 12185:2024-08"],"lab_section":"Punkt Obsługi Laboratoryjnej w Warszawie PP7/4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki Gęstość w temperaturze 15°C\nZakres (700,0 – 900,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08 Paliwa ciekle: benzyna bezolowiowa, olej napedowy, olej opalowy lekki Gestosc w temperaturze 15°C\nZakres (700,0 – 900,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08","categories":["petro"],"row_index":551,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb76d","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki","methodology":"Skład frakcyjny","parameters":[{"name":"Zakres","range":"(30,0 – 370,0) 0C"}],"technique":"Metoda destylacyjna","techniques":["Metoda destylacyjna"],"computed":[],"activity":"Skład frakcyjny\nZakres (30,0 – 370,0) 0C\nMetoda destylacyjna","reference":"PN-EN ISO 3405:2019-05","norm_bases":["PN-EN ISO 3405:2019-05"],"lab_section":"Punkt Obsługi Laboratoryjnej w Warszawie PP7/4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki Skład frakcyjny\nZakres (30,0 – 370,0) 0C\nMetoda destylacyjna PN-EN ISO 3405:2019-05 Paliwa ciekle: benzyna bezolowiowa, olej napedowy, olej opalowy lekki Sklad frakcyjny\nZakres (30,0 – 370,0) 0C\nMetoda destylacyjna PN-EN ISO 3405:2019-05","categories":["petro"],"row_index":552,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb76e","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Gęstość w temperaturze 15°C","parameters":[{"name":"Zakres","range":"(800,0 – 900,0) kg/m3"}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"computed":[],"activity":"Gęstość w temperaturze 15°C\nZakres (800,0 – 900,0) kg/m3\nMetoda oscylacyjna","reference":"PN-EN ISO 12185:2024-08","norm_bases":["PN-EN ISO 12185:2024-08"],"lab_section":"Punkt Obsługi Laboratoryjnej w Warszawie PP7/4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Gęstość w temperaturze 15°C\nZakres (800,0 – 900,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Gestosc w temperaturze 15°C\nZakres (800,0 – 900,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08","categories":["petro"],"row_index":553,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb76f","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość wody","parameters":[{"name":"Zakres","range":"(0,003 – 0,100) %(m/m)"}],"technique":"Metoda miareczkowania kulometrycznego","techniques":["Metoda miareczkowania kulometrycznego"],"computed":[],"activity":"Zawartość wody\nZakres (0,003 – 0,100) %(m/m)\nMetoda miareczkowania kulometrycznego","reference":"PN-EN ISO 12937:2005+Ap1:2021-11","norm_bases":["PN-EN ISO 12937:2005+Ap1:2021-11"],"lab_section":"Punkt Obsługi Laboratoryjnej w Warszawie PP7/4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Zawartość wody\nZakres (0,003 – 0,100) %(m/m)\nMetoda miareczkowania kulometrycznego PN-EN ISO 12937:2005+Ap1:2021-11 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Zawartosc wody\nZakres (0,003 – 0,100) %(m/m)\nMetoda miareczkowania kulometrycznego PN-EN ISO 12937:2005+Ap1:2021-11","categories":["petro","water"],"row_index":554,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb770","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Skłonność do blokowania filtra po wychładzaniu","parameters":[{"name":"Zakres","range":"(50 – 650) s"}],"technique":"Metoda filtracji po wychładzaniu","techniques":["Metoda filtracji po wychładzaniu"],"computed":[],"activity":"Skłonność do blokowania filtra po wychładzaniu\nZakres (50 – 650) s\nMetoda filtracji po wychładzaniu","reference":"ASTM D 7501-22","norm_bases":["ASTM D 7501-22"],"lab_section":"Punkt Obsługi Laboratoryjnej w Warszawie PP7/4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Skłonność do blokowania filtra po wychładzaniu\nZakres (50 – 650) s\nMetoda filtracji po wychładzaniu ASTM D 7501-22 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Sklonnosc do blokowania filtra po wychladzaniu\nZakres (50 – 650) s\nMetoda filtracji po wychladzaniu ASTM D 7501-22","categories":["petro"],"row_index":555,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb771","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Stabilność oksydacyjna","parameters":[{"name":"Zakres","range":"(1,0 – 16,0) h"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Stabilność oksydacyjna\nZakres (1,0 – 16,0) h\nMetoda konduktometryczna","reference":"PN-EN 15751:2014-05","norm_bases":["PN-EN 15751:2014-05"],"lab_section":"Punkt Obsługi Laboratoryjnej w Warszawie PP7/4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Stabilność oksydacyjna\nZakres (1,0 – 16,0) h\nMetoda konduktometryczna PN-EN 15751:2014-05 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Stabilnosc oksydacyjna\nZakres (1,0 – 16,0) h\nMetoda konduktometryczna PN-EN 15751:2014-05","categories":["petro"],"row_index":556,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb772","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki","methodology":"Lepkość kinematyczna w temp. 40 °C","parameters":[{"name":"Zakres","range":"(2,000 – 6,000) mm2/s"}],"technique":"Metoda kapilarna","techniques":["Metoda kapilarna"],"computed":[],"activity":"Lepkość kinematyczna w temp. 40 °C\nZakres (2,000 – 6,000) mm2/s\nMetoda kapilarna","reference":"PN-EN ISO 3104:2024-01 Procedura A","norm_bases":["PN-EN ISO 3104:2024-01 Procedura A"],"lab_section":"Punkt Obsługi Laboratoryjnej w Warszawie PP7/4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki Lepkość kinematyczna w temp. 40 °C\nZakres (2,000 – 6,000) mm2/s\nMetoda kapilarna PN-EN ISO 3104:2024-01 Procedura A Paliwa ciekle: olej napedowy, olej opalowy lekki Lepkosc kinematyczna w temp. 40 °C\nZakres (2,000 – 6,000) mm2/s\nMetoda kapilarna PN-EN ISO 3104:2024-01 Procedura A","categories":["petro"],"row_index":557,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb773","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki","methodology":"Temperatura zapłonu","parameters":[{"name":"Zakres","range":"(40,0 – 100,0) °C"}],"technique":"Metoda zamkniętego tygla Pensky’ego-Martensa","techniques":["Metoda zamkniętego tygla Pensky’ego-Martensa"],"computed":[],"activity":"Temperatura zapłonu\nZakres (40,0 – 100,0) °C\nMetoda zamkniętego tygla Pensky’ego-Martensa","reference":"PN-EN ISO 2719:2016-08+A1:2021-06","norm_bases":["PN-EN ISO 2719:2016-08+A1:2021-06"],"lab_section":"Punkt Obsługi Laboratoryjnej w Warszawie PP7/4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki Temperatura zapłonu\nZakres (40,0 – 100,0) °C\nMetoda zamkniętego tygla Pensky’ego-Martensa PN-EN ISO 2719:2016-08+A1:2021-06 Paliwa ciekle: olej napedowy, olej opalowy lekki Temperatura zaplonu\nZakres (40,0 – 100,0) °C\nMetoda zamknietego tygla Pensky’ego-Martensa PN-EN ISO 2719:2016-08+A1:2021-06","categories":["petro"],"row_index":558,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb774","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki","methodology":"Zawartość wody","parameters":[{"name":"Zakres","range":"(0,003 – 0,100) %(m/m)"}],"technique":"Metoda miareczkowania kulometrycznego","techniques":["Metoda miareczkowania kulometrycznego"],"computed":[],"activity":"Zawartość wody\nZakres (0,003 – 0,100) %(m/m)\nMetoda miareczkowania kulometrycznego","reference":"PN-EN ISO 12937:2005+Ap1:2021-11","norm_bases":["PN-EN ISO 12937:2005+Ap1:2021-11"],"lab_section":"Punkt Obsługi Laboratoryjnej w Warszawie PP7/4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki Zawartość wody\nZakres (0,003 – 0,100) %(m/m)\nMetoda miareczkowania kulometrycznego PN-EN ISO 12937:2005+Ap1:2021-11 Paliwa ciekle: olej napedowy, olej opalowy lekki Zawartosc wody\nZakres (0,003 – 0,100) %(m/m)\nMetoda miareczkowania kulometrycznego PN-EN ISO 12937:2005+Ap1:2021-11","categories":["petro","water"],"row_index":559,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb775","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki","methodology":"Zawartość zanieczyszczeń","parameters":[{"name":"Zakres","range":"(12,0 – 26,0) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość zanieczyszczeń\nZakres (12,0 – 26,0) mg/kg\nMetoda wagowa","reference":"PN-EN 12662-1:2024-11","norm_bases":["PN-EN 12662-1:2024-11"],"lab_section":"Punkt Obsługi Laboratoryjnej w Warszawie PP7/4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki Zawartość zanieczyszczeń\nZakres (12,0 – 26,0) mg/kg\nMetoda wagowa PN-EN 12662-1:2024-11 Paliwa ciekle: olej napedowy, olej opalowy lekki Zawartosc zanieczyszczen\nZakres (12,0 – 26,0) mg/kg\nMetoda wagowa PN-EN 12662-1:2024-11","categories":["petro"],"row_index":560,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb776","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, biopaliwa ciekłe: olej napędowy z FAME","methodology":"Zawartość estrów metylowych kwasów tłuszczowych (FAME)","parameters":[{"name":"Zakres","range":"(3,0 – 20,0) %(v/v)"}],"technique":"Metoda spektrometrii w zakresie podczerwieni IR","techniques":["Metoda spektrometrii w zakresie podczerwieni IR"],"computed":[],"activity":"Zawartość estrów metylowych kwasów tłuszczowych (FAME)\nZakres (3,0 – 20,0) %(v/v)\nMetoda spektrometrii w zakresie podczerwieni IR","reference":"PN-EN 14078:2014-06","norm_bases":["PN-EN 14078:2014-06"],"lab_section":"Punkt Obsługi Laboratoryjnej w Warszawie PP7/4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, biopaliwa ciekłe: olej napędowy z FAME Zawartość estrów metylowych kwasów tłuszczowych (FAME)\nZakres (3,0 – 20,0) %(v/v)\nMetoda spektrometrii w zakresie podczerwieni IR PN-EN 14078:2014-06 Paliwa ciekle: olej napedowy, olej opalowy lekki, biopaliwa ciekle: olej napedowy z FAME Zawartosc estrow metylowych kwasow tluszczowych (FAME)\nZakres (3,0 – 20,0) %(v/v)\nMetoda spektrometrii w zakresie podczerwieni IR PN-EN 14078:2014-06","categories":["petro"],"row_index":561,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb777","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość zanieczyszczeń","parameters":[{"name":"Zakres","range":"(5,0 – 27,0) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość zanieczyszczeń\nZakres (5,0 – 27,0) mg/kg\nMetoda wagowa","reference":"PN-EN 12662-2:2024-11","norm_bases":["PN-EN 12662-2:2024-11"],"lab_section":"Punkt Obsługi Laboratoryjnej w Warszawie PP7/4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Zawartość zanieczyszczeń\nZakres (5,0 – 27,0) mg/kg\nMetoda wagowa PN-EN 12662-2:2024-11 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Zawartosc zanieczyszczen\nZakres (5,0 – 27,0) mg/kg\nMetoda wagowa PN-EN 12662-2:2024-11","categories":["petro"],"row_index":562,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb778","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: bioetanol","methodology":"Moc","parameters":[{"name":"Zakres","range":"(90,0 – 100,0) %(v/v)"}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"computed":[],"activity":"Moc\nZakres (90,0 – 100,0) %(v/v)\nMetoda oscylacyjna","reference":"PN-A-79528-3:2007 p. 5.2","norm_bases":["PN-A-79528-3:2007 p. 5.2"],"lab_section":"Punkt Obsługi Laboratoryjnej w Warszawie PP7/4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: bioetanol Moc\nZakres (90,0 – 100,0) %(v/v)\nMetoda oscylacyjna PN-A-79528-3:2007 p. 5.2 Paliwa ciekle: biopaliwa ciekle: bioetanol Moc\nZakres (90,0 – 100,0) %(v/v)\nMetoda oscylacyjna PN-A-79528-3:2007 p. 5.2","categories":["petro"],"row_index":563,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb779","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: bioetanol","methodology":"Gęstość w temperaturze 20°C","parameters":[{"name":"Zakres","range":"(789,0 – 830,0) kg/m3"}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"computed":[],"activity":"Gęstość w temperaturze 20°C\nZakres (789,0 – 830,0) kg/m3\nMetoda oscylacyjna","reference":"PN-EN ISO 12185:2024-08","norm_bases":["PN-EN ISO 12185:2024-08"],"lab_section":"Punkt Obsługi Laboratoryjnej w Warszawie PP7/4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: bioetanol Gęstość w temperaturze 20°C\nZakres (789,0 – 830,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08 Paliwa ciekle: biopaliwa ciekle: bioetanol Gestosc w temperaturze 20°C\nZakres (789,0 – 830,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08","categories":["petro"],"row_index":564,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb77a","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy","methodology":"Stabilność oksydacyjna","parameters":[{"name":"Zakres","range":"(5,0 – 48,0) h"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Stabilność oksydacyjna\nZakres (5,0 – 48,0) h\nMetoda konduktometryczna","reference":"PN-EN 15751:2014-05","norm_bases":["PN-EN 15751:2014-05"],"lab_section":"Punkt Obsługi Laboratoryjnej w Warszawie PP7/4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy Stabilność oksydacyjna\nZakres (5,0 – 48,0) h\nMetoda konduktometryczna PN-EN 15751:2014-05 Paliwa ciekle: olej napedowy Stabilnosc oksydacyjna\nZakres (5,0 – 48,0) h\nMetoda konduktometryczna PN-EN 15751:2014-05","categories":["petro"],"row_index":565,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb77b","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy","methodology":"Indeks cetanowy (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Indeks cetanowy (z obliczeń)","reference":"PN-EN ISO 4264:2018-08","norm_bases":["PN-EN ISO 4264:2018-08"],"lab_section":"Punkt Obsługi Laboratoryjnej w Warszawie PP7/4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy Indeks cetanowy (z obliczeń) PN-EN ISO 4264:2018-08 Paliwa ciekle: olej napedowy Indeks cetanowy (z obliczen) PN-EN ISO 4264:2018-08","categories":["petro"],"row_index":566,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb77c","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy","methodology":"Temperatura zablokowania zimnego filtra","parameters":[{"name":"[0°C","range":"(- 40)] °C"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Temperatura zablokowania zimnego filtra\n[0°C (- 40)] °C\nMetoda optyczna","reference":"PN-EN 116:2015-09","norm_bases":["PN-EN 116:2015-09"],"lab_section":"Punkt Obsługi Laboratoryjnej w Warszawie PP7/4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy Temperatura zablokowania zimnego filtra\n[0°C (- 40)] °C\nMetoda optyczna PN-EN 116:2015-09 Paliwa ciekle: olej napedowy Temperatura zablokowania zimnego filtra\n[0°C (- 40)] °C\nMetoda optyczna PN-EN 116:2015-09","categories":["petro"],"row_index":567,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb77d","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(2 – 100) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Barwa\nZakres (2 – 100) mg/l Pt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012+Ap1:2015-06 metoda C","norm_bases":["PN-EN ISO 7887:2012+Ap1:2015-06 metoda C"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Barwa\nZakres (2 – 100) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012+Ap1:2015-06 metoda C Woda Barwa\nZakres (2 – 100) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012+Ap1:2015-06 metoda C","categories":["water"],"row_index":568,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb77e","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie benzenu","parameters":[{"name":"Zakres","range":"(0,25 – 10) μg/l"}],"technique":"Metoda chromatografii gazowej ze statyczną analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID)","techniques":["Metoda chromatografii gazowej ze statyczną analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID)"],"computed":[],"activity":"Stężenie benzenu\nZakres (0,25 – 10) μg/l\nMetoda chromatografii gazowej ze statyczną analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID)","reference":"PN-ISO 11423-1:2002","norm_bases":["PN-ISO 11423-1:2002"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie benzenu\nZakres (0,25 – 10) μg/l\nMetoda chromatografii gazowej ze statyczną analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID) PN-ISO 11423-1:2002 Woda Stezenie benzenu\nZakres (0,25 – 10) μg/l\nMetoda chromatografii gazowej ze statyczna analiza fazy nadpowierzchniowej i detekcja plomieniowo-jonizacyjna (HS-GC-FID) PN-ISO 11423-1:2002","categories":["water"],"row_index":569,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb77f","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,50 – 50) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,50 – 50) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Mętność\nZakres (0,50 – 50) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda Metnosc\nZakres (0,50 – 50) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":570,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb780","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, scieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":571,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb781","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0 – 5000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 5000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Zawiesiny ogólne\nZakres (2,0 – 5000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, scieki Zawiesiny ogolne\nZakres (2,0 – 5000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":572,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb782","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Sucha pozostałość","parameters":[{"name":"Zakres","range":"(10 – 5000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha pozostałość\nZakres (10 – 5000) mg/l\nMetoda wagowa","reference":"PN-78/C-04541 pkt 4.1","norm_bases":["PN-78/C-04541 pkt 4.1"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Sucha pozostałość\nZakres (10 – 5000) mg/l\nMetoda wagowa PN-78/C-04541 pkt 4.1 Woda, scieki Sucha pozostalosc\nZakres (10 – 5000) mg/l\nMetoda wagowa PN-78/C-04541 pkt 4.1","categories":["water"],"row_index":573,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb783","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(10 – 1 300) mS/m"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (10 – 1 300) mS/m\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Przewodność elektryczna właściwa\nZakres (10 – 1 300) mS/m\nMetoda konduktometryczna PN-EN 27888:1999 Woda, scieki Przewodnosc elektryczna wlasciwa\nZakres (10 – 1 300) mS/m\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":574,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb784","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotynów","parameters":[{"name":"Zakres","range":"(0,050 – 33) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotynów\nZakres (0,050 – 33) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotynów\nZakres (0,050 – 33) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, scieki Stezenie azotynow\nZakres (0,050 – 33) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":575,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb785","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu azotynowego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu azotynowego (z obliczeń)","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu azotynowego (z obliczeń) PN-EN 26777:1999 Woda, scieki Stezenie azotu azotynowego (z obliczen) PN-EN 26777:1999","categories":["water"],"row_index":576,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb786","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotynów","parameters":[{"name":"Zakres","range":"(0,050 – 20) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie azotynów\nZakres (0,050 – 20) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotynów\nZakres (0,050 – 20) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Woda, scieki Stezenie azotynow\nZakres (0,050 – 20) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":577,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb787","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu azotynowego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu azotynowego (z obliczeń)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu azotynowego (z obliczeń) PN-EN ISO 10304-1:2009+AC:2012 Woda, scieki Stezenie azotu azotynowego (z obliczen) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":578,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb788","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotanów","parameters":[{"name":"Zakres","range":"(0,050 – 2000) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie azotanów\nZakres (0,050 – 2000) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotanów\nZakres (0,050 – 2000) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Woda, scieki Stezenie azotanow\nZakres (0,050 – 2000) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":579,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb789","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu azotanowego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu azotanowego (z obliczeń)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu azotanowego (z obliczeń) PN-EN ISO 10304-1:2009+AC:2012 Woda, scieki Stezenie azotu azotanowego (z obliczen) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":580,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb78a","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotanów","parameters":[{"name":"Zakres","range":"(0,18 – 2200) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotanów\nZakres (0,18 – 2200) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotanów\nZakres (0,18 – 2200) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08 Woda, scieki Stezenie azotanow\nZakres (0,18 – 2200) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":581,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb78b","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu azotanowego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu azotanowego (z obliczeń)","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu azotanowego (z obliczeń) PN-82/C-04576/08 Woda, scieki Stezenie azotu azotanowego (z obliczen) PN-82/C-04576/08","categories":["water"],"row_index":582,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb78c","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(3,4 – 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (3,4 – 1000) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001 z wyłączeniem pkt. 11.1","norm_bases":["PN-EN 25663:2001 z wyłączeniem pkt. 11.1"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu Kjeldahla\nZakres (3,4 – 1000) mg/l\nMetoda miareczkowa PN-EN 25663:2001 z wyłączeniem pkt. 11.1 Woda, scieki Stezenie azotu Kjeldahla\nZakres (3,4 – 1000) mg/l\nMetoda miareczkowa PN-EN 25663:2001 z wylaczeniem pkt. 11.1","categories":["water"],"row_index":583,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb78d","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu ogólnego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"Metoda nr 047 Wydanie 5 z dnia 19.11.2019","norm_bases":["Metoda nr 047 Wydanie 5 z dnia 19.11.2019"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu ogólnego (z obliczeń) Metoda nr 047 Wydanie 5 z dnia 19.11.2019 Woda, scieki Stezenie azotu ogolnego (z obliczen) Metoda nr 047 Wydanie 5 z dnia 19.11.2019","categories":["water"],"row_index":584,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb78e","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,47 – 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,47 – 1000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu amonowego\nZakres (0,47 – 1000) mg/l\nMetoda miareczkowa PN-ISO 5664:2002 Woda, scieki Stezenie azotu amonowego\nZakres (0,47 – 1000) mg/l\nMetoda miareczkowa PN-ISO 5664:2002","categories":["water"],"row_index":585,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb78f","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie jonu amonowego, amoniaku (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie jonu amonowego, amoniaku (z obliczeń)","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie jonu amonowego, amoniaku (z obliczeń) PN-ISO 5664:2002 Woda, scieki Stezenie jonu amonowego, amoniaku (z obliczen) PN-ISO 5664:2002","categories":["water"],"row_index":586,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb790","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,050 – 5,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,050 – 5,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu amonowego\nZakres (0,050 – 5,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, scieki Stezenie azotu amonowego\nZakres (0,050 – 5,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":587,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb791","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie jonu amonowego, amoniaku (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie jonu amonowego, amoniaku (z obliczeń)","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie jonu amonowego, amoniaku (z obliczeń) PN-ISO 7150-1:2002 Woda, scieki Stezenie jonu amonowego, amoniaku (z obliczen) PN-ISO 7150-1:2002","categories":["water"],"row_index":588,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb792","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,016 – 32) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,016 – 32) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010","norm_bases":["PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie fosforu ogólnego\nZakres (0,016 – 32) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 Woda, scieki Stezenie fosforu ogolnego\nZakres (0,016 – 32) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010","categories":["water"],"row_index":589,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb793","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie fosforanów","parameters":[{"name":"Zakres","range":"(0,050 – 100) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie fosforanów\nZakres (0,050 – 100) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie fosforanów\nZakres (0,050 – 100) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Woda, scieki Stezenie fosforanow\nZakres (0,050 – 100) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":590,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb794","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie żelaza","parameters":[{"name":"Zakres","range":"(0,010 – 10,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza\nZakres (0,010 – 10,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001+Ap1:2016-6","norm_bases":["PN-ISO 6332:2001+Ap1:2016-6"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie żelaza\nZakres (0,010 – 10,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-6 Woda, scieki Stezenie zelaza\nZakres (0,010 – 10,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-6","categories":["water"],"row_index":591,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb795","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie manganu","parameters":[{"name":"Zakres","range":"(0,030 – 4,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie manganu\nZakres (0,030 – 4,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-92/C-04590/03","norm_bases":["PN-92/C-04590/03"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie manganu\nZakres (0,030 – 4,0) mg/l\nMetoda spektrofotometryczna PN-92/C-04590/03 Woda, scieki Stezenie manganu\nZakres (0,030 – 4,0) mg/l\nMetoda spektrofotometryczna PN-92/C-04590/03","categories":["water"],"row_index":592,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb796","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie substancji ekstrahujących się eterem naftowym","parameters":[{"name":"Zakres","range":"(10 – 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie substancji ekstrahujących się eterem naftowym\nZakres (10 – 1000) mg/l\nMetoda wagowa","reference":"PN-86/C-04573/01","norm_bases":["PN-86/C-04573/01"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie substancji ekstrahujących się eterem naftowym\nZakres (10 – 1000) mg/l\nMetoda wagowa PN-86/C-04573/01 Woda, scieki Stezenie substancji ekstrahujacych sie eterem naftowym\nZakres (10 – 1000) mg/l\nMetoda wagowa PN-86/C-04573/01","categories":["water"],"row_index":593,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb797","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu (BZT5)","parameters":[{"name":"Zakres","range":"(1 – 6000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu (BZT5)\nZakres (1 – 6000) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu (BZT5)\nZakres (1 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Woda, scieki Biochemiczne zapotrzebowanie tlenu (BZT5)\nZakres (1 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":594,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb798","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie tlenu rozpuszczonego","parameters":[{"name":"Zakres","range":"(0,2 – 10) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Stężenie tlenu rozpuszczonego\nZakres (0,2 – 10) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5814:2013-04","norm_bases":["PN-EN ISO 5814:2013-04"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie tlenu rozpuszczonego\nZakres (0,2 – 10) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5814:2013-04 Woda, scieki Stezenie tlenu rozpuszczonego\nZakres (0,2 – 10) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5814:2013-04","categories":["water"],"row_index":595,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb799","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Chemiczne zapotrzebowanie tlenu – ChZT-Cr","parameters":[{"name":"Zakres","range":"(9,0 – 3000) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu – ChZT-Cr\nZakres (9,0 – 3000) mg/l O2\nMetoda miareczkowa","reference":"PN-74/C-04578-03","norm_bases":["PN-74/C-04578-03"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Chemiczne zapotrzebowanie tlenu – ChZT-Cr\nZakres (9,0 – 3000) mg/l O2\nMetoda miareczkowa PN-74/C-04578-03 Woda, scieki Chemiczne zapotrzebowanie tlenu – ChZT-Cr\nZakres (9,0 – 3000) mg/l O2\nMetoda miareczkowa PN-74/C-04578-03","categories":["water"],"row_index":596,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb79a","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Chemiczne zapotrzebowanie tlenu ChZT-Cr","parameters":[{"name":"Zakres","range":"(25 – 1000) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu ChZT-Cr\nZakres (25 – 1000) mg/l O2\nMetoda miareczkowa","reference":"PN-ISO 6060:2006","norm_bases":["PN-ISO 6060:2006"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Chemiczne zapotrzebowanie tlenu ChZT-Cr\nZakres (25 – 1000) mg/l O2\nMetoda miareczkowa PN-ISO 6060:2006 Woda, scieki Chemiczne zapotrzebowanie tlenu ChZT-Cr\nZakres (25 – 1000) mg/l O2\nMetoda miareczkowa PN-ISO 6060:2006","categories":["water"],"row_index":597,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb79b","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Chemiczne zapotrzebowanie tlenu ChZT-Cr","parameters":[{"name":"Zakres","range":"(10 – 10000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu ChZT-Cr\nZakres (10 – 10000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Chemiczne zapotrzebowanie tlenu ChZT-Cr\nZakres (10 – 10000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda, scieki Chemiczne zapotrzebowanie tlenu ChZT-Cr\nZakres (10 – 10000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":598,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb79c","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(0,050 – 5000) mg/l"}],"technique":"Metoda chromatografii jonowej (IC) z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej (IC) z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie siarczanów\nZakres (0,050 – 5000) mg/l\nMetoda chromatografii jonowej (IC) z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie siarczanów\nZakres (0,050 – 5000) mg/l\nMetoda chromatografii jonowej (IC) z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Woda, scieki Stezenie siarczanow\nZakres (0,050 – 5000) mg/l\nMetoda chromatografii jonowej (IC) z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":599,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb79d","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(0,10 – 5000) mg/l"}],"technique":"Metoda chromatografii jonowej (IC) z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej (IC) z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie chlorków\nZakres (0,10 – 5000) mg/l\nMetoda chromatografii jonowej (IC) z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie chlorków\nZakres (0,10 – 5000) mg/l\nMetoda chromatografii jonowej (IC) z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Woda, scieki Stezenie chlorkow\nZakres (0,10 – 5000) mg/l\nMetoda chromatografii jonowej (IC) z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":600,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb79e","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Indeks nadmanganianowy","parameters":[{"name":"Zakres","range":"(0,50 – 100) mg O2/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Indeks nadmanganianowy\nZakres (0,50 – 100) mg O2/l\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Indeks nadmanganianowy\nZakres (0,50 – 100) mg O2/l\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda, scieki Indeks nadmanganianowy\nZakres (0,50 – 100) mg O2/l\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":601,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb79f","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie glinu","parameters":[{"name":"Zakres","range":"(0,0100 – 10,0) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie glinu\nZakres (0,0100 – 10,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie glinu\nZakres (0,0100 – 10,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Woda, scieki Stezenie glinu\nZakres (0,0100 – 10,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["water"],"row_index":602,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb7a0","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)","parameters":[{"name":"Zakres","range":"(0,050 – 40) mmol/l"},{"name":"Zakres","range":"(5,0 – 4000) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres:\nZakres (0,050 – 40) mmol/l\nZakres (5,0 – 4000) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres:\nZakres (0,050 – 40) mmol/l\nZakres (5,0 – 4000) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999 Woda, scieki Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna)\nZakres:\nZakres (0,050 – 40) mmol/l\nZakres (5,0 – 4000) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":603,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb7a1","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie wapnia","parameters":[{"name":"Zakres","range":"(0,050 – 25) mmol/l"},{"name":"Zakres","range":"(2,0 – 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie wapnia\nZakres:\nZakres (0,050 – 25) mmol/l\nZakres (2,0 – 1000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 6058:1999","norm_bases":["PN-ISO 6058:1999"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie wapnia\nZakres:\nZakres (0,050 – 25) mmol/l\nZakres (2,0 – 1000) mg/l\nMetoda miareczkowa PN-ISO 6058:1999 Woda, scieki Stezenie wapnia\nZakres:\nZakres (0,050 – 25) mmol/l\nZakres (2,0 – 1000) mg/l\nMetoda miareczkowa PN-ISO 6058:1999","categories":["water"],"row_index":604,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb7a2","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie magnezu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie magnezu (z obliczeń)","reference":"PN-C 04554-4:1999 Załącznik A","norm_bases":["PN-C 04554-4:1999 Załącznik A"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie magnezu (z obliczeń) PN-C 04554-4:1999 Załącznik A Woda, scieki Stezenie magnezu (z obliczen) PN-C 04554-4:1999 Zalacznik A","categories":["water"],"row_index":605,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb7a3","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(20 – 5000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie siarczanów\nZakres (20 – 5000) mg/l\nMetoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie siarczanów\nZakres (20 – 5000) mg/l\nMetoda wagowa PN-ISO 9280:2002 Woda, scieki Stezenie siarczanow\nZakres (20 – 5000) mg/l\nMetoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":606,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb7a4","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5 – 25 000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5 – 25 000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie chlorków\nZakres (5 – 25 000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda, scieki Stezenie chlorkow\nZakres (5 – 25 000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":607,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb7a5","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Indeks oleju mineralnego","parameters":[{"name":"Zakres","range":"(0,10 – 100) mg/l"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Indeks oleju mineralnego\nZakres (0,10 – 100) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN ISO 9377-2:2003","norm_bases":["PN-EN ISO 9377-2:2003"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Indeks oleju mineralnego\nZakres (0,10 – 100) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN ISO 9377-2:2003 Woda, scieki Indeks oleju mineralnego\nZakres (0,10 – 100) mg/l\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN ISO 9377-2:2003","categories":["water","petro"],"row_index":608,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb7a6","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie chlorku winylu","parameters":[{"name":"Zakres","range":"(0,10 – 1,0) mg/l"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie chlorku winylu\nZakres (0,10 – 1,0) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Metoda nr 192 Wydanie 1 z dnia 26.09.2019","norm_bases":["Metoda nr 192 Wydanie 1 z dnia 26.09.2019"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie chlorku winylu\nZakres (0,10 – 1,0) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Metoda nr 192 Wydanie 1 z dnia 26.09.2019 Woda, scieki Stezenie chlorku winylu\nZakres (0,10 – 1,0) mg/l\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Metoda nr 192 Wydanie 1 z dnia 26.09.2019","categories":["water"],"row_index":609,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb7a7","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie chlorowcowych pochodnych węglowodorów","parameters":[{"name":"Zakres","range":"1,2-dichloroetan (0,0010 – 0,10) mg/l"},{"name":"Tetrachlorometan","range":"(0,00050–0,10) mg/l"},{"name":"Tetrachloroetylen","range":"(0,0010 –0,10) mg/l"},{"name":"trichloroetylen","range":"(0,0010 –0,10) mg/l"},{"name":"trichlorometan","range":"(0,0010 –0,10) mg/l"},{"name":"heksachlorobutadien","range":"(0,00010 – 0,010) mg/l"}],"technique":"Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","techniques":["Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)"],"computed":[],"activity":"Stężenie chlorowcowych pochodnych węglowodorów\nZakres:\nZakres 1,2-dichloroetan (0,0010 – 0,10) mg/l\nTetrachlorometan (0,00050–0,10) mg/l\nTetrachloroetylen (0,0010 –0,10) mg/l\ntrichloroetylen (0,0010 –0,10) mg/l\ntrichlorometan (0,0010 –0,10) mg/l\nheksachlorobutadien (0,00010 – 0,010) mg/l\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","reference":"PN-EN ISO 10301:2002","norm_bases":["PN-EN ISO 10301:2002"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie chlorowcowych pochodnych węglowodorów\nZakres:\nZakres 1,2-dichloroetan (0,0010 – 0,10) mg/l\nTetrachlorometan (0,00050–0,10) mg/l\nTetrachloroetylen (0,0010 –0,10) mg/l\ntrichloroetylen (0,0010 –0,10) mg/l\ntrichlorometan (0,0010 –0,10) mg/l\nheksachlorobutadien (0,00010 – 0,010) mg/l\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) PN-EN ISO 10301:2002 Woda, scieki Stezenie chlorowcowych pochodnych weglowodorow\nZakres:\nZakres 1,2-dichloroetan (0,0010 – 0,10) mg/l\nTetrachlorometan (0,00050–0,10) mg/l\nTetrachloroetylen (0,0010 –0,10) mg/l\ntrichloroetylen (0,0010 –0,10) mg/l\ntrichlorometan (0,0010 –0,10) mg/l\nheksachlorobutadien (0,00010 – 0,010) mg/l\nMetoda chromatografii gazowej z detekcja wychwytu elektronow (GC-ECD) PN-EN ISO 10301:2002","categories":["water"],"row_index":610,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb7a8","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie ogólnego węgla","parameters":[{"name":"organicznego (OWO) i rozpuszczonego węgla"},{"name":"organicznego (RWO)"},{"name":"Zakres","range":"(0,30 – 1000) mg/l"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Stężenie ogólnego węgla\nZakres:\norganicznego (OWO) i rozpuszczonego węgla\norganicznego (RWO)\nZakres (0,30 – 1000) mg/l\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN 1484:1999","norm_bases":["PN-EN 1484:1999"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie ogólnego węgla\nZakres:\norganicznego (OWO) i rozpuszczonego węgla\norganicznego (RWO)\nZakres (0,30 – 1000) mg/l\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN 1484:1999 Woda, scieki Stezenie ogolnego wegla\nZakres:\norganicznego (OWO) i rozpuszczonego wegla\norganicznego (RWO)\nZakres (0,30 – 1000) mg/l\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN 1484:1999","categories":["water"],"row_index":611,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb7a9","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie stałych związków rozpuszczonych (TDS)","parameters":[{"name":"Zakres","range":"(10,0 – 5000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie stałych związków rozpuszczonych (TDS)\nZakres (10,0 – 5000) mg/l\nMetoda wagowa","reference":"PN-EN 15216:2022-03","norm_bases":["PN-EN 15216:2022-03"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie stałych związków rozpuszczonych (TDS)\nZakres (10,0 – 5000) mg/l\nMetoda wagowa PN-EN 15216:2022-03 Woda, scieki Stezenie stalych zwiazkow rozpuszczonych (TDS)\nZakres (10,0 – 5000) mg/l\nMetoda wagowa PN-EN 15216:2022-03","categories":["water"],"row_index":612,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb7aa","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie chloru ogólnego (całkowitego)","parameters":[{"name":"Zakres","range":"(0,030 – 5) mg/l"},{"name":"Stężenie chloru wolnego"},{"name":"Zakres","range":"(0,030 – 3,5) mg/l"},{"name":"Chlor związany (z obliczeń)"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chloru ogólnego (całkowitego)\nZakres:\nZakres (0,030 – 5) mg/l\nStężenie chloru wolnego\nZakres (0,030 – 3,5) mg/l\nChlor związany (z obliczeń)\nMetoda miareczkowa","reference":"PN-EN ISO 7393-1:2011","norm_bases":["PN-EN ISO 7393-1:2011"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie chloru ogólnego (całkowitego)\nZakres:\nZakres (0,030 – 5) mg/l\nStężenie chloru wolnego\nZakres (0,030 – 3,5) mg/l\nChlor związany (z obliczeń)\nMetoda miareczkowa PN-EN ISO 7393-1:2011 Woda, scieki Stezenie chloru ogolnego (calkowitego)\nZakres:\nZakres (0,030 – 5) mg/l\nStezenie chloru wolnego\nZakres (0,030 – 3,5) mg/l\nChlor zwiazany (z obliczen)\nMetoda miareczkowa PN-EN ISO 7393-1:2011","categories":["water"],"row_index":613,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb7ab","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie heksachlorobenzenu","parameters":[{"name":"Zakres","range":"(0,010 – 0,10) μg/l"}],"technique":"Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","techniques":["Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)"],"computed":[],"activity":"Stężenie heksachlorobenzenu\nZakres (0,010 – 0,10) μg/l\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","reference":"PN-EN ISO 6468:2002","norm_bases":["PN-EN ISO 6468:2002"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie heksachlorobenzenu\nZakres (0,010 – 0,10) μg/l\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) PN-EN ISO 6468:2002 Woda, scieki Stezenie heksachlorobenzenu\nZakres (0,010 – 0,10) μg/l\nMetoda chromatografii gazowej z detekcja wychwytu elektronow (GC-ECD) PN-EN ISO 6468:2002","categories":["water"],"row_index":614,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb7ac","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie węglowodorów aromatycznych","parameters":[{"name":"benzen","range":"(0,0010 – 100) mg/l"},{"name":"toluen","range":"(0,0010 – 100) mg/l"},{"name":"etylobenzen","range":"(0,0010 – 100) mg/l"},{"name":"styren","range":"(0,0010 – 100) mg/l"},{"name":"o-ksylen","range":"(0,0010 – 100) mg/l"},{"name":"(m+p)-ksylen","range":"(0,0020 – 200) mg/l"}],"technique":"Metoda chromatografii gazowej ze statyczną analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID)","techniques":["Metoda chromatografii gazowej ze statyczną analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID)"],"computed":[],"activity":"Stężenie węglowodorów aromatycznych\nZakres:\nbenzen (0,0010 – 100) mg/l\ntoluen (0,0010 – 100) mg/l\netylobenzen (0,0010 – 100) mg/l\nstyren (0,0010 – 100) mg/l\no-ksylen (0,0010 – 100) mg/l\n(m+p)-ksylen (0,0020 – 200) mg/l\nMetoda chromatografii gazowej ze statyczną analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID)","reference":"PN-ISO 11423-1:2002","norm_bases":["PN-ISO 11423-1:2002"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie węglowodorów aromatycznych\nZakres:\nbenzen (0,0010 – 100) mg/l\ntoluen (0,0010 – 100) mg/l\netylobenzen (0,0010 – 100) mg/l\nstyren (0,0010 – 100) mg/l\no-ksylen (0,0010 – 100) mg/l\n(m+p)-ksylen (0,0020 – 200) mg/l\nMetoda chromatografii gazowej ze statyczną analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID) PN-ISO 11423-1:2002 Woda, scieki Stezenie weglowodorow aromatycznych\nZakres:\nbenzen (0,0010 – 100) mg/l\ntoluen (0,0010 – 100) mg/l\netylobenzen (0,0010 – 100) mg/l\nstyren (0,0010 – 100) mg/l\no-ksylen (0,0010 – 100) mg/l\n(m+p)-ksylen (0,0020 – 200) mg/l\nMetoda chromatografii gazowej ze statyczna analiza fazy nadpowierzchniowej i detekcja plomieniowo-jonizacyjna (HS-GC-FID) PN-ISO 11423-1:2002","categories":["water"],"row_index":615,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb7ad","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Suma węglowodorów aromatycznych (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma węglowodorów aromatycznych (z obliczeń)","reference":"PN-ISO 11423-1:2002","norm_bases":["PN-ISO 11423-1:2002"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Suma węglowodorów aromatycznych (z obliczeń) PN-ISO 11423-1:2002 Woda, scieki Suma weglowodorow aromatycznych (z obliczen) PN-ISO 11423-1:2002","categories":["water"],"row_index":616,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb7ae","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie trihalometanów","parameters":[{"name":"chloroform","range":"(1,0- 250) μg/l"},{"name":"chlorodibromometan","range":"(1,0- 250) μg/l"},{"name":"dichlorobromometan","range":"(1,0- 250) μg/l"},{"name":"bromoform","range":"(1,0- 250) μg/l"}],"technique":"Metoda chromatografii gazowej ze statyczną analizą fazy nadpowierzchniowej i detekcją wychwytu elektronów (HS-GC-ECD)","techniques":["Metoda chromatografii gazowej ze statyczną analizą fazy nadpowierzchniowej i detekcją wychwytu elektronów (HS-GC-ECD)"],"computed":[],"activity":"Stężenie trihalometanów\nZakres:\nchloroform (1,0- 250) μg/l\nchlorodibromometan (1,0- 250) μg/l\ndichlorobromometan (1,0- 250) μg/l\nbromoform (1,0- 250) μg/l\nMetoda chromatografii gazowej ze statyczną analizą fazy nadpowierzchniowej i detekcją wychwytu elektronów (HS-GC-ECD)","reference":"PN-EN ISO 10301:2002","norm_bases":["PN-EN ISO 10301:2002"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie trihalometanów\nZakres:\nchloroform (1,0- 250) μg/l\nchlorodibromometan (1,0- 250) μg/l\ndichlorobromometan (1,0- 250) μg/l\nbromoform (1,0- 250) μg/l\nMetoda chromatografii gazowej ze statyczną analizą fazy nadpowierzchniowej i detekcją wychwytu elektronów (HS-GC-ECD) PN-EN ISO 10301:2002 Woda, scieki Stezenie trihalometanow\nZakres:\nchloroform (1,0- 250) μg/l\nchlorodibromometan (1,0- 250) μg/l\ndichlorobromometan (1,0- 250) μg/l\nbromoform (1,0- 250) μg/l\nMetoda chromatografii gazowej ze statyczna analiza fazy nadpowierzchniowej i detekcja wychwytu elektronow (HS-GC-ECD) PN-EN ISO 10301:2002","categories":["water"],"row_index":617,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb7af","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Suma trihalometanów (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma trihalometanów (z obliczeń)","reference":"PN-EN ISO 10301:2002","norm_bases":["PN-EN ISO 10301:2002"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Suma trihalometanów (z obliczeń) PN-EN ISO 10301:2002 Woda, scieki Suma trihalometanow (z obliczen) PN-EN ISO 10301:2002","categories":["water"],"row_index":618,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb7b0","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie chlorowcowych pochodnych węglowodorów","parameters":[{"name":"Zakres","range":"1,2-dichloroetan (0,25 – 10) μg/l"},{"name":"tetrachlorometan","range":"(0,10 – 10) μg/l"},{"name":"tetrachloroetylen","range":"(0,10 – 10) μg/l"},{"name":"trichloroetylen","range":"(0,10 – 10) μg/l"},{"name":"trichlorometan","range":"(0,25 – 10) μg/l"}],"technique":"Metoda chromatografii gazowej ze statyczną analizą fazy nadpowierzchniowej i detekcją wychwytu elektronów (HS-GC-ECD)","techniques":["Metoda chromatografii gazowej ze statyczną analizą fazy nadpowierzchniowej i detekcją wychwytu elektronów (HS-GC-ECD)"],"computed":[],"activity":"Stężenie chlorowcowych pochodnych węglowodorów\nZakres:\nZakres 1,2-dichloroetan (0,25 – 10) μg/l\ntetrachlorometan (0,10 – 10) μg/l\ntetrachloroetylen (0,10 – 10) μg/l\ntrichloroetylen (0,10 – 10) μg/l\ntrichlorometan (0,25 – 10) μg/l\nMetoda chromatografii gazowej ze statyczną analizą fazy nadpowierzchniowej i detekcją wychwytu elektronów (HS-GC-ECD)","reference":"PN-EN ISO 10301:2002","norm_bases":["PN-EN ISO 10301:2002"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie chlorowcowych pochodnych węglowodorów\nZakres:\nZakres 1,2-dichloroetan (0,25 – 10) μg/l\ntetrachlorometan (0,10 – 10) μg/l\ntetrachloroetylen (0,10 – 10) μg/l\ntrichloroetylen (0,10 – 10) μg/l\ntrichlorometan (0,25 – 10) μg/l\nMetoda chromatografii gazowej ze statyczną analizą fazy nadpowierzchniowej i detekcją wychwytu elektronów (HS-GC-ECD) PN-EN ISO 10301:2002 Woda, scieki Stezenie chlorowcowych pochodnych weglowodorow\nZakres:\nZakres 1,2-dichloroetan (0,25 – 10) μg/l\ntetrachlorometan (0,10 – 10) μg/l\ntetrachloroetylen (0,10 – 10) μg/l\ntrichloroetylen (0,10 – 10) μg/l\ntrichlorometan (0,25 – 10) μg/l\nMetoda chromatografii gazowej ze statyczna analiza fazy nadpowierzchniowej i detekcja wychwytu elektronow (HS-GC-ECD) PN-EN ISO 10301:2002","categories":["water"],"row_index":619,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb7b1","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Suma tetrachloroetylenu i trichloroetylenu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma tetrachloroetylenu i trichloroetylenu (z obliczeń)","reference":"PN-EN ISO 10301:2002","norm_bases":["PN-EN ISO 10301:2002"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Suma tetrachloroetylenu i trichloroetylenu (z obliczeń) PN-EN ISO 10301:2002 Woda, scieki Suma tetrachloroetylenu i trichloroetylenu (z obliczen) PN-EN ISO 10301:2002","categories":["water"],"row_index":620,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb7b2","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie chlorowcowych pochodnych węglowodorów","parameters":[{"name":"chlorek winylu","range":"(0,25 – 100) μg/l"},{"name":"Zakres","range":"1,2-dichloroetan (0,010 – 20) mg/l"},{"name":"tetrachlorometan","range":"(0,010 – 20) mg/l"},{"name":"tetrachloroetylen","range":"(0,010 – 20) mg/l"},{"name":"trichloroetylen","range":"(0,010 – 20) mg/l"},{"name":"trichlorometan","range":"(0,010 – 20) mg/l"}],"technique":"Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID)","techniques":["Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID)"],"computed":[],"activity":"Stężenie chlorowcowych pochodnych węglowodorów\nZakres:\nchlorek winylu (0,25 – 100) μg/l\nZakres 1,2-dichloroetan (0,010 – 20) mg/l\ntetrachlorometan (0,010 – 20) mg/l\ntetrachloroetylen (0,010 – 20) mg/l\ntrichloroetylen (0,010 – 20) mg/l\ntrichlorometan (0,010 – 20) mg/l\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID)","reference":"PN-EN ISO 10301:2002","norm_bases":["PN-EN ISO 10301:2002"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie chlorowcowych pochodnych węglowodorów\nZakres:\nchlorek winylu (0,25 – 100) μg/l\nZakres 1,2-dichloroetan (0,010 – 20) mg/l\ntetrachlorometan (0,010 – 20) mg/l\ntetrachloroetylen (0,010 – 20) mg/l\ntrichloroetylen (0,010 – 20) mg/l\ntrichlorometan (0,010 – 20) mg/l\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID) PN-EN ISO 10301:2002 Woda, scieki Stezenie chlorowcowych pochodnych weglowodorow\nZakres:\nchlorek winylu (0,25 – 100) μg/l\nZakres 1,2-dichloroetan (0,010 – 20) mg/l\ntetrachlorometan (0,010 – 20) mg/l\ntetrachloroetylen (0,010 – 20) mg/l\ntrichloroetylen (0,010 – 20) mg/l\ntrichlorometan (0,010 – 20) mg/l\nMetoda chromatografii gazowej z analiza fazy nadpowierzchniowej i detekcja plomieniowo-jonizacyjna (HS-GC-FID) PN-EN ISO 10301:2002","categories":["water"],"row_index":621,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb7b3","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie fluorków","parameters":[{"name":"Zakres","range":"(0,050 – 100) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie fluorków\nZakres (0,050 – 100) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie fluorków\nZakres (0,050 – 100) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Woda, scieki Stezenie fluorkow\nZakres (0,050 – 100) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":622,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb7b4","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie cyjanków ogólnych, wolnych i związanych","parameters":[{"name":"Zakres","range":"(0,010 – 0,30) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie cyjanków ogólnych, wolnych i związanych\nZakres (0,010 – 0,30) mg/l\nMetoda spektrofotometryczna","reference":"Metoda nr 193 Wydanie 1 z dnia 26.09.2019 Test Spectroquant 1.14561.0001","norm_bases":["Metoda nr 193 Wydanie 1 z dnia 26.09.2019 Test Spectroquant 1.14561.0001"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie cyjanków ogólnych, wolnych i związanych\nZakres (0,010 – 0,30) mg/l\nMetoda spektrofotometryczna Metoda nr 193 Wydanie 1 z dnia 26.09.2019 Test Spectroquant 1.14561.0001 Woda, scieki Stezenie cyjankow ogolnych, wolnych i zwiazanych\nZakres (0,010 – 0,30) mg/l\nMetoda spektrofotometryczna Metoda nr 193 Wydanie 1 z dnia 26.09.2019 Test Spectroquant 1.14561.0001","categories":["water"],"row_index":623,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb7b5","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Cyjanki związane (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cyjanki związane (z obliczeń)","reference":"Metoda nr 193 Wydanie 1 z dnia 26.09.2019 Test Spectroquant 1.14561.0001","norm_bases":["Metoda nr 193 Wydanie 1 z dnia 26.09.2019 Test Spectroquant 1.14561.0001"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Cyjanki związane (z obliczeń) Metoda nr 193 Wydanie 1 z dnia 26.09.2019 Test Spectroquant 1.14561.0001 Woda, scieki Cyjanki zwiazane (z obliczen) Metoda nr 193 Wydanie 1 z dnia 26.09.2019 Test Spectroquant 1.14561.0001","categories":["water"],"row_index":624,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb7b6","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie pierwiastków","parameters":[{"name":"kadm","range":"(0,00200 – 10,0) mg/l"},{"name":"chrom ogólny","range":"(0,00200 – 10,0) mg/l"},{"name":"miedź","range":"(0,00200 – 10,0) mg/l"},{"name":"nikiel","range":"(0,00500 – 10,0) mg/l"},{"name":"ołów","range":"(0,0100 – 50,0) mg/l"},{"name":"cynk","range":"(0,00500 – 50,0) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie pierwiastków\nZakres:\nkadm (0,00200 – 10,0) mg/l\nchrom ogólny (0,00200 – 10,0) mg/l\nmiedź (0,00200 – 10,0) mg/l\nnikiel (0,00500 – 10,0) mg/l\nołów (0,0100 – 50,0) mg/l\ncynk (0,00500 – 50,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie pierwiastków\nZakres:\nkadm (0,00200 – 10,0) mg/l\nchrom ogólny (0,00200 – 10,0) mg/l\nmiedź (0,00200 – 10,0) mg/l\nnikiel (0,00500 – 10,0) mg/l\nołów (0,0100 – 50,0) mg/l\ncynk (0,00500 – 50,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Woda, scieki Stezenie pierwiastkow\nZakres:\nkadm (0,00200 – 10,0) mg/l\nchrom ogolny (0,00200 – 10,0) mg/l\nmiedz (0,00200 – 10,0) mg/l\nnikiel (0,00500 – 10,0) mg/l\nolow (0,0100 – 50,0) mg/l\ncynk (0,00500 – 50,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["water"],"row_index":625,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb7b7","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie pierwiastków","parameters":[{"name":"kobalt","range":"(0,00500 – 10,0) mg/l"},{"name":"żelazo","range":"(0,0200 – 50,0) mg/l"},{"name":"mangan","range":"(0,00200 – 50,0) mg/l"},{"name":"wanad","range":"(0,0200 – 10,0) mg/l"},{"name":"bar","range":"(0,00200 – 10,0) mg/l"},{"name":"bor","range":"(0,0100 – 1,00) mg/l"},{"name":"sód","range":"(0,500 – 2000) mg/l"},{"name":"molibden","range":"(0,00800 – 10,0) mg/l"},{"name":"wapń","range":"(0,200 – 1000) mg/l"},{"name":"magnez","range":"(0,100 – 1000) mg/l"},{"name":"potas","range":"(0,100 – 1000) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie pierwiastków\nZakres:\nkobalt (0,00500 – 10,0) mg/l\nżelazo (0,0200 – 50,0) mg/l\nmangan (0,00200 – 50,0) mg/l\nwanad (0,0200 – 10,0) mg/l\nbar (0,00200 – 10,0) mg/l\nbor (0,0100 – 1,00) mg/l\nsód (0,500 – 2000) mg/l\nmolibden (0,00800 – 10,0) mg/l\nwapń (0,200 – 1000) mg/l\nmagnez (0,100 – 1000) mg/l\npotas (0,100 – 1000) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie pierwiastków\nZakres:\nkobalt (0,00500 – 10,0) mg/l\nżelazo (0,0200 – 50,0) mg/l\nmangan (0,00200 – 50,0) mg/l\nwanad (0,0200 – 10,0) mg/l\nbar (0,00200 – 10,0) mg/l\nbor (0,0100 – 1,00) mg/l\nsód (0,500 – 2000) mg/l\nmolibden (0,00800 – 10,0) mg/l\nwapń (0,200 – 1000) mg/l\nmagnez (0,100 – 1000) mg/l\npotas (0,100 – 1000) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Woda, scieki Stezenie pierwiastkow\nZakres:\nkobalt (0,00500 – 10,0) mg/l\nzelazo (0,0200 – 50,0) mg/l\nmangan (0,00200 – 50,0) mg/l\nwanad (0,0200 – 10,0) mg/l\nbar (0,00200 – 10,0) mg/l\nbor (0,0100 – 1,00) mg/l\nsod (0,500 – 2000) mg/l\nmolibden (0,00800 – 10,0) mg/l\nwapn (0,200 – 1000) mg/l\nmagnez (0,100 – 1000) mg/l\npotas (0,100 – 1000) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["water"],"row_index":626,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb7b8","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie pierwiastków","parameters":[{"name":"arsen","range":"(0,0200 – 1,00) mg/l"},{"name":"antymon","range":"(0,0200 – 1,00) mg/l"},{"name":"selen","range":"(0,0100 – 1,00) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES)"],"computed":[],"activity":"Stężenie pierwiastków\nZakres:\narsen (0,0200 – 1,00) mg/l\nantymon (0,0200 – 1,00) mg/l\nselen (0,0100 – 1,00) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie pierwiastków\nZakres:\narsen (0,0200 – 1,00) mg/l\nantymon (0,0200 – 1,00) mg/l\nselen (0,0100 – 1,00) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES) PN-EN ISO 11885:2009 Woda, scieki Stezenie pierwiastkow\nZakres:\narsen (0,0200 – 1,00) mg/l\nantymon (0,0200 – 1,00) mg/l\nselen (0,0100 – 1,00) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej z generowaniem wodorkow (HG-ICP-OES) PN-EN ISO 11885:2009","categories":["water"],"row_index":627,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb7b9","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie rtęci","parameters":[{"name":"Zakres","range":"(0,20 – 70) μg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","techniques":["Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji"],"computed":[],"activity":"Stężenie rtęci\nZakres (0,20 – 70) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","reference":"Metoda nr 194 Wydanie 1 z dnia 26.09.2019","norm_bases":["Metoda nr 194 Wydanie 1 z dnia 26.09.2019"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie rtęci\nZakres (0,20 – 70) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji Metoda nr 194 Wydanie 1 z dnia 26.09.2019 Woda, scieki Stezenie rteci\nZakres (0,20 – 70) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z technika amalgamacji Metoda nr 194 Wydanie 1 z dnia 26.09.2019","categories":["water"],"row_index":628,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb7ba","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Steżenie węglowodorów C6-C12","parameters":[{"name":"Zakres","range":"(0,020 - 1000) mg/l"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Steżenie węglowodorów C6-C12\nZakres (0,020 - 1000) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-C-04643:1994","norm_bases":["PN-C-04643:1994"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Steżenie węglowodorów C6-C12\nZakres (0,020 - 1000) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-C-04643:1994 Woda, scieki Stezenie weglowodorow C6-C12\nZakres (0,020 - 1000) mg/l\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-C-04643:1994","categories":["water"],"row_index":629,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb7bb","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Steżenie węglowodorów C12-C35","parameters":[{"name":"Zakres","range":"(0,50 – 5000) mg/l"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Steżenie węglowodorów C12-C35\nZakres (0,50 – 5000) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-C-04643:1994","norm_bases":["PN-C-04643:1994"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Steżenie węglowodorów C12-C35\nZakres (0,50 – 5000) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-C-04643:1994 Woda, scieki Stezenie weglowodorow C12-C35\nZakres (0,50 – 5000) mg/l\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-C-04643:1994","categories":["water"],"row_index":630,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb7bc","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Suma węglowodorów C6-C35 (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma węglowodorów C6-C35 (z obliczeń)","reference":"PN-C-04643:1994","norm_bases":["PN-C-04643:1994"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Suma węglowodorów C6-C35 (z obliczeń) PN-C-04643:1994 Woda, scieki Suma weglowodorow C6-C35 (z obliczen) PN-C-04643:1994","categories":["water"],"row_index":631,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb7bd","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Zasadowość wobec fenololoftaleiny","parameters":[{"name":"Zakres","range":"(0,40 – 20) mmol/l"},{"name":"Zasadowość ogólna"},{"name":"Zakres","range":"(0,40 – 20) mmol/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zasadowość wobec fenololoftaleiny\nZakres:\nZakres (0,40 – 20) mmol/l\nZasadowość ogólna\nZakres (0,40 – 20) mmol/l\nMetoda miareczkowa","reference":"PN-EN ISO 9963-1:2001+Ap1:2004","norm_bases":["PN-EN ISO 9963-1:2001+Ap1:2004"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Zasadowość wobec fenololoftaleiny\nZakres:\nZakres (0,40 – 20) mmol/l\nZasadowość ogólna\nZakres (0,40 – 20) mmol/l\nMetoda miareczkowa PN-EN ISO 9963-1:2001+Ap1:2004 Woda, scieki Zasadowosc wobec fenololoftaleiny\nZakres:\nZakres (0,40 – 20) mmol/l\nZasadowosc ogolna\nZakres (0,40 – 20) mmol/l\nMetoda miareczkowa PN-EN ISO 9963-1:2001+Ap1:2004","categories":["water"],"row_index":632,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb7be","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Wyroby chemiczne: oleje elektroizolacyjne","methodology":"Stężenie polichlorowanych bifenyli (PCB)","parameters":[{"name":"Aroclor 1242","range":"(5,0 – 50) mg/kg"},{"name":"Aroclor 1254","range":"(5,0 – 50) mg/kg"},{"name":"Aroclor 1260","range":"(5,0 – 50) mg/kg"}],"technique":"Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","techniques":["Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)"],"computed":[],"activity":"Stężenie polichlorowanych bifenyli (PCB)\nZakres:\nAroclor 1242 (5,0 – 50) mg/kg\nAroclor 1254 (5,0 – 50) mg/kg\nAroclor 1260 (5,0 – 50) mg/kg\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","reference":"PN-IEC 997:1998","norm_bases":["PN-IEC 997:1998"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby chemiczne: oleje elektroizolacyjne Stężenie polichlorowanych bifenyli (PCB)\nZakres:\nAroclor 1242 (5,0 – 50) mg/kg\nAroclor 1254 (5,0 – 50) mg/kg\nAroclor 1260 (5,0 – 50) mg/kg\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) PN-IEC 997:1998 Wyroby chemiczne: oleje elektroizolacyjne Stezenie polichlorowanych bifenyli (PCB)\nZakres:\nAroclor 1242 (5,0 – 50) mg/kg\nAroclor 1254 (5,0 – 50) mg/kg\nAroclor 1260 (5,0 – 50) mg/kg\nMetoda chromatografii gazowej z detekcja wychwytu elektronow (GC-ECD) PN-IEC 997:1998","categories":["petro"],"row_index":633,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb7bf","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko ogólne – próbki gazów odlotowych pobrane na rurki z sorbentem","methodology":"Zawartość związków organicznych","parameters":[{"name":"chlorek winylu"},{"name":"Zakres","range":"(0,050 – 250) μg w próbce"},{"name":"1,2-dichloroetan (0,10 – 250) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość związków organicznych\nZakres:\nchlorek winylu\nZakres (0,050 – 250) μg w próbce\n1,2-dichloroetan (0,10 – 250) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – próbki gazów odlotowych pobrane na rurki z sorbentem Zawartość związków organicznych\nZakres:\nchlorek winylu\nZakres (0,050 – 250) μg w próbce\n1,2-dichloroetan (0,10 – 250) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Srodowisko ogolne – probki gazow odlotowych pobrane na rurki z sorbentem Zawartosc zwiazkow organicznych\nZakres:\nchlorek winylu\nZakres (0,050 – 250) μg w probce\n1,2-dichloroetan (0,10 – 250) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["environment"],"row_index":634,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb7c0","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko ogólne – próbki gazów odlotowych pobrane na rurki z sorbentem","methodology":"Zawartość trichlorometanu","parameters":[{"name":"Zakres","range":"(1,0 – 250) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość trichlorometanu\nZakres (1,0 – 250) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – próbki gazów odlotowych pobrane na rurki z sorbentem Zawartość trichlorometanu\nZakres (1,0 – 250) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Srodowisko ogolne – probki gazow odlotowych pobrane na rurki z sorbentem Zawartosc trichlorometanu\nZakres (1,0 – 250) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["environment"],"row_index":635,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb7c1","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko ogólne – próbki gazów odlotowych pobrane na rurki z sorbentem","methodology":"Zawartość sumy węglowodorów aromatycznych: benzen, etylobenzen, styren, toluen, o-ksylen, (m+p)ksyleny (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość sumy węglowodorów aromatycznych: benzen, etylobenzen, styren, toluen, o-ksylen, (m+p)ksyleny (z obliczeń)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – próbki gazów odlotowych pobrane na rurki z sorbentem Zawartość sumy węglowodorów aromatycznych: benzen, etylobenzen, styren, toluen, o-ksylen, (m+p)ksyleny (z obliczeń) PN-EN 13649:2005 Srodowisko ogolne – probki gazow odlotowych pobrane na rurki z sorbentem Zawartosc sumy weglowodorow aromatycznych: benzen, etylobenzen, styren, toluen, o-ksylen, (m+p)ksyleny (z obliczen) PN-EN 13649:2005","categories":["environment"],"row_index":636,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb7c2","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko ogólne – próbki gazów odlotowych pobrane na rurki z sorbentem","methodology":"Zawartość związków organicznych węglowodory alifatyczne C5 – C12","parameters":[{"name":"Zakres","range":"(1,0 – 500) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość związków organicznych węglowodory alifatyczne C5 – C12\nZakres (1,0 – 500) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – próbki gazów odlotowych pobrane na rurki z sorbentem Zawartość związków organicznych węglowodory alifatyczne C5 – C12\nZakres (1,0 – 500) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Srodowisko ogolne – probki gazow odlotowych pobrane na rurki z sorbentem Zawartosc zwiazkow organicznych weglowodory alifatyczne C5 – C12\nZakres (1,0 – 500) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["environment"],"row_index":637,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb7c3","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko ogólne – próbki gazów odlotowych pobrane na rurki z sorbentem","methodology":"Zawartość metanolu","parameters":[{"name":"Zakres","range":"(5,0 – 100) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość metanolu\nZakres (5,0 – 100) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – próbki gazów odlotowych pobrane na rurki z sorbentem Zawartość metanolu\nZakres (5,0 – 100) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Srodowisko ogolne – probki gazow odlotowych pobrane na rurki z sorbentem Zawartosc metanolu\nZakres (5,0 – 100) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["environment"],"row_index":638,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb7c4","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko ogólne – próbki gazów odlotowych pobrane na rurki z sorbentem","methodology":"Zawartość związków organicznych","parameters":[{"name":"o-ksylen (1,0 – 2 500) μg w próbce (m+p)-ksylen (1,0 – 5000) μg w próbce toluen (1,0 – 2 500) μg w próbce styren (1,0 – 2 500) μg w próbce metyloetyloketon"},{"name":"Zakres","range":"(1,0 – 2 500) μg w próbce"},{"name":"octan metylu (1,0 – 2 500) μg w próbce etylobenzen (1,0 – 2 500) μg w próbce benzen (1,0 – 2 500) μg w próbce (o+m+p)-ksylen (1,0 – 7 500) μg w próbce tetrachloroetylen (1,0 – 3 000) μg w próbce bromometan (5,0 – 2 500) μg w próbce trichloroeten (1,0 – 500) μg w próbce 1,1 dichloroeten (1,0 – 500) μg w próbce 1,2 dichloroeten (1,0 – 500) μg w próbce 1,1,2 trichloroetan (1,0 – 500) μg w próbce tetrachlorometan (1,0 – 500) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość związków organicznych\nZakres:\no-ksylen (1,0 – 2 500) μg w próbce (m+p)-ksylen (1,0 – 5000) μg w próbce toluen (1,0 – 2 500) μg w próbce styren (1,0 – 2 500) μg w próbce metyloetyloketon\nZakres (1,0 – 2 500) μg w próbce\noctan metylu (1,0 – 2 500) μg w próbce etylobenzen (1,0 – 2 500) μg w próbce benzen (1,0 – 2 500) μg w próbce (o+m+p)-ksylen (1,0 – 7 500) μg w próbce tetrachloroetylen (1,0 – 3 000) μg w próbce bromometan (5,0 – 2 500) μg w próbce trichloroeten (1,0 – 500) μg w próbce 1,1 dichloroeten (1,0 – 500) μg w próbce 1,2 dichloroeten (1,0 – 500) μg w próbce 1,1,2 trichloroetan (1,0 – 500) μg w próbce tetrachlorometan (1,0 – 500) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – próbki gazów odlotowych pobrane na rurki z sorbentem Zawartość związków organicznych\nZakres:\no-ksylen (1,0 – 2 500) μg w próbce (m+p)-ksylen (1,0 – 5000) μg w próbce toluen (1,0 – 2 500) μg w próbce styren (1,0 – 2 500) μg w próbce metyloetyloketon\nZakres (1,0 – 2 500) μg w próbce\noctan metylu (1,0 – 2 500) μg w próbce etylobenzen (1,0 – 2 500) μg w próbce benzen (1,0 – 2 500) μg w próbce (o+m+p)-ksylen (1,0 – 7 500) μg w próbce tetrachloroetylen (1,0 – 3 000) μg w próbce bromometan (5,0 – 2 500) μg w próbce trichloroeten (1,0 – 500) μg w próbce 1,1 dichloroeten (1,0 – 500) μg w próbce 1,2 dichloroeten (1,0 – 500) μg w próbce 1,1,2 trichloroetan (1,0 – 500) μg w próbce tetrachlorometan (1,0 – 500) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Srodowisko ogolne – probki gazow odlotowych pobrane na rurki z sorbentem Zawartosc zwiazkow organicznych\nZakres:\no-ksylen (1,0 – 2 500) μg w probce (m+p)-ksylen (1,0 – 5000) μg w probce toluen (1,0 – 2 500) μg w probce styren (1,0 – 2 500) μg w probce metyloetyloketon\nZakres (1,0 – 2 500) μg w probce\noctan metylu (1,0 – 2 500) μg w probce etylobenzen (1,0 – 2 500) μg w probce benzen (1,0 – 2 500) μg w probce (o+m+p)-ksylen (1,0 – 7 500) μg w probce tetrachloroetylen (1,0 – 3 000) μg w probce bromometan (5,0 – 2 500) μg w probce trichloroeten (1,0 – 500) μg w probce 1,1 dichloroeten (1,0 – 500) μg w probce 1,2 dichloroeten (1,0 – 500) μg w probce 1,1,2 trichloroetan (1,0 – 500) μg w probce tetrachlorometan (1,0 – 500) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["environment"],"row_index":639,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb7c5","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko ogólne – próbki gazów odlotowych pobrane na rurki z sorbentem","methodology":"Zawartość glikolu etylenowego","parameters":[{"name":"Zakres","range":"(100 – 2500) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość glikolu etylenowego\nZakres (100 – 2500) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – próbki gazów odlotowych pobrane na rurki z sorbentem Zawartość glikolu etylenowego\nZakres (100 – 2500) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Srodowisko ogolne – probki gazow odlotowych pobrane na rurki z sorbentem Zawartosc glikolu etylenowego\nZakres (100 – 2500) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["environment"],"row_index":640,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb7c6","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy – próbki powietrza pobrane na filtry","methodology":"Zawartość kwasu siarkowego - frakcja torakalna","parameters":[{"name":"Zakres","range":"(0,0026 – 0,10) mg w próbce"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną"],"computed":[],"activity":"Zawartość kwasu siarkowego - frakcja torakalna\nZakres (0,0026 – 0,10) mg w próbce\nMetoda chromatografii jonowej z detekcją konduktometryczną","reference":"Podstawy Metody Oceny Środowiska Pracy 2012 nr 1(71) + 2017 nr 2 (92)","norm_bases":["Podstawy Metody Oceny Środowiska Pracy 2012 nr 1(71) + 2017 nr 2 (92)"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – próbki powietrza pobrane na filtry Zawartość kwasu siarkowego - frakcja torakalna\nZakres (0,0026 – 0,10) mg w próbce\nMetoda chromatografii jonowej z detekcją konduktometryczną Podstawy Metody Oceny Środowiska Pracy 2012 nr 1(71) + 2017 nr 2 (92) Srodowisko pracy – probki powietrza pobrane na filtry Zawartosc kwasu siarkowego - frakcja torakalna\nZakres (0,0026 – 0,10) mg w probce\nMetoda chromatografii jonowej z detekcja konduktometryczna Podstawy Metody Oceny Srodowiska Pracy 2012 nr 1(71) + 2017 nr 2 (92)","categories":["environment"],"row_index":641,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb7c7","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko ogólne – próbki gazów odlotowych pobrane na filtry","methodology":"Zawartość arsenu i antymonu","parameters":[{"name":"As","range":"(0,000500 – 0,05000) mg w"},{"name":"próbce"},{"name":"Sb","range":"(0,00100 – 0,0500) mg w próbce"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES)"],"computed":[],"activity":"Zawartość arsenu i antymonu\nZakres:\nAs (0,000500 – 0,05000) mg w\npróbce\nSb (0,00100 – 0,0500) mg w próbce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES)","reference":"PN-EN 14385:2025:05","norm_bases":["PN-EN 14385:2025:05"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – próbki gazów odlotowych pobrane na filtry Zawartość arsenu i antymonu\nZakres:\nAs (0,000500 – 0,05000) mg w\npróbce\nSb (0,00100 – 0,0500) mg w próbce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES) PN-EN 14385:2025:05 Srodowisko ogolne – probki gazow odlotowych pobrane na filtry Zawartosc arsenu i antymonu\nZakres:\nAs (0,000500 – 0,05000) mg w\nprobce\nSb (0,00100 – 0,0500) mg w probce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej z generowaniem wodorkow (HG-ICP-OES) PN-EN 14385:2025:05","categories":["environment"],"row_index":642,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb7c8","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko ogólne – próbki gazów odlotowych pobrane na filtry","methodology":"Zawartość pierwiastków:","parameters":[{"name":"Cd","range":"(0,000250 – 0,500) mg w próbce"},{"name":"Cr","range":"(0,000250 – 0,500) mg w próbce"},{"name":"Co","range":"(0,000250 – 0,500) mg w próbce"},{"name":"Cu","range":"(0,000250 – 0,500) mg w próbce"},{"name":"Mn","range":"(0,000250 – 0,500) mg w próbce"},{"name":"Ni","range":"(0,000500 – 0,500) mg w próbce"},{"name":"Pb","range":"(0,00250 – 2,50) mg w próbce"},{"name":"Tl","range":"(0,000500 – 0,0500) mg w próbce"},{"name":"V","range":"(0,00250 – 0,0500) mg w próbce"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość pierwiastków:\nZakres:\nCd (0,000250 – 0,500) mg w próbce\nCr (0,000250 – 0,500) mg w próbce\nCo (0,000250 – 0,500) mg w próbce\nCu (0,000250 – 0,500) mg w próbce\nMn (0,000250 – 0,500) mg w próbce\nNi (0,000500 – 0,500) mg w próbce\nPb (0,00250 – 2,50) mg w próbce\nTl (0,000500 – 0,0500) mg w próbce\nV (0,00250 – 0,0500) mg w próbce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN 14385:2025:05","norm_bases":["PN-EN 14385:2025:05"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – próbki gazów odlotowych pobrane na filtry Zawartość pierwiastków:\nZakres:\nCd (0,000250 – 0,500) mg w próbce\nCr (0,000250 – 0,500) mg w próbce\nCo (0,000250 – 0,500) mg w próbce\nCu (0,000250 – 0,500) mg w próbce\nMn (0,000250 – 0,500) mg w próbce\nNi (0,000500 – 0,500) mg w próbce\nPb (0,00250 – 2,50) mg w próbce\nTl (0,000500 – 0,0500) mg w próbce\nV (0,00250 – 0,0500) mg w próbce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN 14385:2025:05 Srodowisko ogolne – probki gazow odlotowych pobrane na filtry Zawartosc pierwiastkow:\nZakres:\nCd (0,000250 – 0,500) mg w probce\nCr (0,000250 – 0,500) mg w probce\nCo (0,000250 – 0,500) mg w probce\nCu (0,000250 – 0,500) mg w probce\nMn (0,000250 – 0,500) mg w probce\nNi (0,000500 – 0,500) mg w probce\nPb (0,00250 – 2,50) mg w probce\nTl (0,000500 – 0,0500) mg w probce\nV (0,00250 – 0,0500) mg w probce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN 14385:2025:05","categories":["environment"],"row_index":643,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb7c9","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko ogólne – próbki gazów odlotowych pobrane na filtry","methodology":"Zawartość rtęci","parameters":[{"name":"Zakres","range":"(0,0005 – 0,05) mg w próbce"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES)"],"computed":[],"activity":"Zawartość rtęci\nZakres (0,0005 – 0,05) mg w próbce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES)","reference":"PN-EN 13211:2006","norm_bases":["PN-EN 13211:2006"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – próbki gazów odlotowych pobrane na filtry Zawartość rtęci\nZakres (0,0005 – 0,05) mg w próbce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES) PN-EN 13211:2006 Srodowisko ogolne – probki gazow odlotowych pobrane na filtry Zawartosc rteci\nZakres (0,0005 – 0,05) mg w probce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej z generowaniem wodorkow (HG-ICP-OES) PN-EN 13211:2006","categories":["environment"],"row_index":644,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb7ca","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko ogólne – próbki gazów odlotowych pobrane do roztworów pochłaniających","methodology":"Zawartość pierwiastków:","parameters":[{"name":"Cd (0,000500 – 1,00) mg w próbce Cr (0,000500 – 1,00) mg w próbce Co (0,000500 – 1,00) mg w próbce Cu (0,000200 – 1,00) mg w próbce Mn (0,000200 – 1,00) mg w próbce Ni (0,00100 – 1,00) mg w próbce Pb (0,00500 – 5,00) mg w próbce Tl (0,00100 – 0,100) mg w próbce V (0,00500 – 0,100) mg w próbce"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość pierwiastków:\nCd (0,000500 – 1,00) mg w próbce Cr (0,000500 – 1,00) mg w próbce Co (0,000500 – 1,00) mg w próbce Cu (0,000200 – 1,00) mg w próbce Mn (0,000200 – 1,00) mg w próbce Ni (0,00100 – 1,00) mg w próbce Pb (0,00500 – 5,00) mg w próbce Tl (0,00100 – 0,100) mg w próbce V (0,00500 – 0,100) mg w próbce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN 14385:2025:05","norm_bases":["PN-EN 14385:2025:05"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – próbki gazów odlotowych pobrane do roztworów pochłaniających Zawartość pierwiastków:\nCd (0,000500 – 1,00) mg w próbce Cr (0,000500 – 1,00) mg w próbce Co (0,000500 – 1,00) mg w próbce Cu (0,000200 – 1,00) mg w próbce Mn (0,000200 – 1,00) mg w próbce Ni (0,00100 – 1,00) mg w próbce Pb (0,00500 – 5,00) mg w próbce Tl (0,00100 – 0,100) mg w próbce V (0,00500 – 0,100) mg w próbce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN 14385:2025:05 Srodowisko ogolne – probki gazow odlotowych pobrane do roztworow pochlaniajacych Zawartosc pierwiastkow:\nCd (0,000500 – 1,00) mg w probce Cr (0,000500 – 1,00) mg w probce Co (0,000500 – 1,00) mg w probce Cu (0,000200 – 1,00) mg w probce Mn (0,000200 – 1,00) mg w probce Ni (0,00100 – 1,00) mg w probce Pb (0,00500 – 5,00) mg w probce Tl (0,00100 – 0,100) mg w probce V (0,00500 – 0,100) mg w probce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN 14385:2025:05","categories":["environment"],"row_index":645,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb7cb","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko ogólne – próbki gazów odlotowych pobrane do roztworów pochłaniających","methodology":"Zawartość arsenu, antymonu","parameters":[{"name":"As","range":"(0,00100 – 0,100) mg w próbce"},{"name":"Sb","range":"(0,00200 – 0,100) mg w próbce"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES)"],"computed":[],"activity":"Zawartość arsenu, antymonu\nZakres:\nAs (0,00100 – 0,100) mg w próbce\nSb (0,00200 – 0,100) mg w próbce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES)","reference":"PN-EN 14385:2025:05","norm_bases":["PN-EN 14385:2025:05"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – próbki gazów odlotowych pobrane do roztworów pochłaniających Zawartość arsenu, antymonu\nZakres:\nAs (0,00100 – 0,100) mg w próbce\nSb (0,00200 – 0,100) mg w próbce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES) PN-EN 14385:2025:05 Srodowisko ogolne – probki gazow odlotowych pobrane do roztworow pochlaniajacych Zawartosc arsenu, antymonu\nZakres:\nAs (0,00100 – 0,100) mg w probce\nSb (0,00200 – 0,100) mg w probce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej z generowaniem wodorkow (HG-ICP-OES) PN-EN 14385:2025:05","categories":["environment"],"row_index":646,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb7cc","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko ogólne – próbki gazów odlotowych pobrane do roztworów pochłaniających","methodology":"Zawartość rtęci","parameters":[{"name":"Zakres","range":"(0,000500 – 0,0500) mg w"},{"name":"próbce"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES)"],"computed":[],"activity":"Zawartość rtęci\nZakres:\nZakres (0,000500 – 0,0500) mg w\npróbce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES)","reference":"PN-EN 13211:2006","norm_bases":["PN-EN 13211:2006"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – próbki gazów odlotowych pobrane do roztworów pochłaniających Zawartość rtęci\nZakres:\nZakres (0,000500 – 0,0500) mg w\npróbce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES) PN-EN 13211:2006 Srodowisko ogolne – probki gazow odlotowych pobrane do roztworow pochlaniajacych Zawartosc rteci\nZakres:\nZakres (0,000500 – 0,0500) mg w\nprobce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej z generowaniem wodorkow (HG-ICP-OES) PN-EN 13211:2006","categories":["environment"],"row_index":647,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb7cd","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko ogólne – próbki gazów odlotowych pobrane do roztworów pochłaniających","methodology":"Zawartość chlorowodoru","parameters":[{"name":"Zakres","range":"(0,050 – 100) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość chlorowodoru\nZakres (0,050 – 100) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-EN 1911:2011","norm_bases":["PN-EN 1911:2011"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – próbki gazów odlotowych pobrane do roztworów pochłaniających Zawartość chlorowodoru\nZakres (0,050 – 100) mg w próbce\nMetoda spektrofotometryczna PN-EN 1911:2011 Srodowisko ogolne – probki gazow odlotowych pobrane do roztworow pochlaniajacych Zawartosc chlorowodoru\nZakres (0,050 – 100) mg w probce\nMetoda spektrofotometryczna PN-EN 1911:2011","categories":["environment"],"row_index":648,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb7ce","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko ogólne – próbki gazów odlotowych pobrane do roztworów pochłaniających","methodology":"Zawartość bromowodoru","parameters":[{"name":"Zakres","range":"(0,028 – 1,0) mg w próbce"}],"technique":"Metoda turbidymetryczna","techniques":["Metoda turbidymetryczna"],"computed":[],"activity":"Zawartość bromowodoru\nZakres (0,028 – 1,0) mg w próbce\nMetoda turbidymetryczna","reference":"Metoda nr 201 Wydanie 1 z dnia 26.09.2019","norm_bases":["Metoda nr 201 Wydanie 1 z dnia 26.09.2019"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – próbki gazów odlotowych pobrane do roztworów pochłaniających Zawartość bromowodoru\nZakres (0,028 – 1,0) mg w próbce\nMetoda turbidymetryczna Metoda nr 201 Wydanie 1 z dnia 26.09.2019 Srodowisko ogolne – probki gazow odlotowych pobrane do roztworow pochlaniajacych Zawartosc bromowodoru\nZakres (0,028 – 1,0) mg w probce\nMetoda turbidymetryczna Metoda nr 201 Wydanie 1 z dnia 26.09.2019","categories":["environment"],"row_index":649,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb7cf","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko ogólne - próbki gazów odlotowych pobrane do roztworów pochłaniających","methodology":"Zawartość amoniaku","parameters":[{"name":"Zakres","range":"(0,0061 – 9,7) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość amoniaku\nZakres (0,0061 – 9,7) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-EN ISO 21877:2020-03","norm_bases":["PN-EN ISO 21877:2020-03"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne - próbki gazów odlotowych pobrane do roztworów pochłaniających Zawartość amoniaku\nZakres (0,0061 – 9,7) mg w próbce\nMetoda spektrofotometryczna PN-EN ISO 21877:2020-03 Srodowisko ogolne - probki gazow odlotowych pobrane do roztworow pochlaniajacych Zawartosc amoniaku\nZakres (0,0061 – 9,7) mg w probce\nMetoda spektrofotometryczna PN-EN ISO 21877:2020-03","categories":["environment"],"row_index":650,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb7d0","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko ogólne – próbki powietrza atmosferycznego pobrane na rurki z sorbentem","methodology":"Zawartość chlorku winylu","parameters":[{"name":"Zakres","range":"(0,020 – 0,50) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość chlorku winylu\nZakres (0,020 – 0,50) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Metoda nr 202 Wydanie 1 z dnia 26.09.2019","norm_bases":["Metoda nr 202 Wydanie 1 z dnia 26.09.2019"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – próbki powietrza atmosferycznego pobrane na rurki z sorbentem Zawartość chlorku winylu\nZakres (0,020 – 0,50) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Metoda nr 202 Wydanie 1 z dnia 26.09.2019 Srodowisko ogolne – probki powietrza atmosferycznego pobrane na rurki z sorbentem Zawartosc chlorku winylu\nZakres (0,020 – 0,50) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Metoda nr 202 Wydanie 1 z dnia 26.09.2019","categories":["environment"],"row_index":651,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb7d1","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko ogólne – próbki powietrza atmosferycznego pobrane na rurki z sorbentem","methodology":"Zawartość 1,2-dichloroetanu","parameters":[{"name":"Zakres","range":"(0,10 – 2,0) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość 1,2-dichloroetanu\nZakres (0,10 – 2,0) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Metoda nr 202 Wydanie 1 z dnia 26.09.2019","norm_bases":["Metoda nr 202 Wydanie 1 z dnia 26.09.2019"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – próbki powietrza atmosferycznego pobrane na rurki z sorbentem Zawartość 1,2-dichloroetanu\nZakres (0,10 – 2,0) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Metoda nr 202 Wydanie 1 z dnia 26.09.2019 Srodowisko ogolne – probki powietrza atmosferycznego pobrane na rurki z sorbentem Zawartosc 1,2-dichloroetanu\nZakres (0,10 – 2,0) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Metoda nr 202 Wydanie 1 z dnia 26.09.2019","categories":["environment"],"row_index":652,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb7d2","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Gleba","methodology":"Sucha masa","parameters":[{"name":"Zakres","range":"(10,0 – 999) g/kg"},{"name":"Zakres","range":"(1,0 – 99,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha masa\nZakres:\nZakres (10,0 – 999) g/kg\nZakres (1,0 – 99,0) %\nMetoda wagowa","reference":"PN-ISO 11465:1999","norm_bases":["PN-ISO 11465:1999"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Sucha masa\nZakres:\nZakres (10,0 – 999) g/kg\nZakres (1,0 – 99,0) %\nMetoda wagowa PN-ISO 11465:1999 Gleba Sucha masa\nZakres:\nZakres (10,0 – 999) g/kg\nZakres (1,0 – 99,0) %\nMetoda wagowa PN-ISO 11465:1999","categories":["environment"],"row_index":653,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb7d3","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Gleba","methodology":"Steżenie węglowodorów C6-C12","parameters":[{"name":"Zakres","range":"(12,5 – 10000) mg/kg"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Steżenie węglowodorów C6-C12\nZakres (12,5 – 10000) mg/kg\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN ISO 16703:2011","norm_bases":["PN-EN ISO 16703:2011"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Steżenie węglowodorów C6-C12\nZakres (12,5 – 10000) mg/kg\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN ISO 16703:2011 Gleba Stezenie weglowodorow C6-C12\nZakres (12,5 – 10000) mg/kg\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN ISO 16703:2011","categories":["environment"],"row_index":654,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb7d4","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Gleba","methodology":"Stężenie węglowodorów C12-C35","parameters":[{"name":"Zakres","range":"(12,5 – 10000) mg/kg"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie węglowodorów C12-C35\nZakres (12,5 – 10000) mg/kg\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN ISO 16703:2011","norm_bases":["PN-EN ISO 16703:2011"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Stężenie węglowodorów C12-C35\nZakres (12,5 – 10000) mg/kg\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN ISO 16703:2011 Gleba Stezenie weglowodorow C12-C35\nZakres (12,5 – 10000) mg/kg\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN ISO 16703:2011","categories":["environment"],"row_index":655,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb7d5","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Gleba","methodology":"Suma węglowodorów C6-C35 (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma węglowodorów C6-C35 (z obliczeń)","reference":"PN-EN ISO 16703:2011","norm_bases":["PN-EN ISO 16703:2011"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Suma węglowodorów C6-C35 (z obliczeń) PN-EN ISO 16703:2011 Gleba Suma weglowodorow C6-C35 (z obliczen) PN-EN ISO 16703:2011","categories":["environment"],"row_index":656,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb7d6","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Osady ściekowe, Odpady O: kod 19 08 05","methodology":"Sucha pozostałość","parameters":[{"name":"Zakres","range":"(10,0 – 990) g/kg"},{"name":"Zakres","range":"(1,0 – 99,0) %"},{"name":"Zawartość wody"},{"name":"Zakres","range":"(1,0 – 99,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha pozostałość\nZakres:\nZakres (10,0 – 990) g/kg\nZakres (1,0 – 99,0) %\nZawartość wody\nZakres (1,0 – 99,0) %\nMetoda wagowa","reference":"PN-EN 15934:2013-02","norm_bases":["PN-EN 15934:2013-02"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":"O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Osady ściekowe, Odpady O: kod 19 08 05 Sucha pozostałość\nZakres:\nZakres (10,0 – 990) g/kg\nZakres (1,0 – 99,0) %\nZawartość wody\nZakres (1,0 – 99,0) %\nMetoda wagowa PN-EN 15934:2013-02 Osady sciekowe, Odpady O: kod 19 08 05 Sucha pozostalosc\nZakres:\nZakres (10,0 – 990) g/kg\nZakres (1,0 – 99,0) %\nZawartosc wody\nZakres (1,0 – 99,0) %\nMetoda wagowa PN-EN 15934:2013-02","categories":["water","environment"],"row_index":657,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb7d7","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Osady ściekowe, Odpady O: kod 19 08 05","methodology":"Straty przy prażeniu suchej masy","parameters":[{"name":"Zakres","range":"(2,0 – 98,0)%"},{"name":"Pozostałość po prażeniu suchej masy (z obliczeń)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Straty przy prażeniu suchej masy\nZakres:\nZakres (2,0 – 98,0)%\nPozostałość po prażeniu suchej masy (z obliczeń)\nMetoda wagowa","reference":"PN-EN 15935:2022-01","norm_bases":["PN-EN 15935:2022-01"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":"O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Osady ściekowe, Odpady O: kod 19 08 05 Straty przy prażeniu suchej masy\nZakres:\nZakres (2,0 – 98,0)%\nPozostałość po prażeniu suchej masy (z obliczeń)\nMetoda wagowa PN-EN 15935:2022-01 Osady sciekowe, Odpady O: kod 19 08 05 Straty przy prazeniu suchej masy\nZakres:\nZakres (2,0 – 98,0)%\nPozostalosc po prazeniu suchej masy (z obliczen)\nMetoda wagowa PN-EN 15935:2022-01","categories":["water","environment"],"row_index":658,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb7d8","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: wodór (automotive)","methodology":"Zawartość wody","parameters":[{"name":"Zakres","range":"(2,00 – 20,00) μmol/mol"}],"technique":"Metoda spektrometrii strat we wnęce optycznej z falą ciągłą (CRDS)","techniques":["Metoda spektrometrii strat we wnęce optycznej z falą ciągłą (CRDS)"],"computed":[],"activity":"Zawartość wody\nZakres (2,00 – 20,00) μmol/mol\nMetoda spektrometrii strat we wnęce optycznej z falą ciągłą (CRDS)","reference":"ASTM D7941/D7941M-23","norm_bases":["ASTM D7941/D7941M-23"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: wodór (automotive) Zawartość wody\nZakres (2,00 – 20,00) μmol/mol\nMetoda spektrometrii strat we wnęce optycznej z falą ciągłą (CRDS) ASTM D7941/D7941M-23 Paliwa gazowe: wodor (automotive) Zawartosc wody\nZakres (2,00 – 20,00) μmol/mol\nMetoda spektrometrii strat we wnece optycznej z fala ciagla (CRDS) ASTM D7941/D7941M-23","categories":["water","petro","automotive"],"row_index":659,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb7d9","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: wodór (automotive)","methodology":"Zawartość helu","parameters":[{"name":"Zakres","range":"(25,0 – 600) μmol/mol"},{"name":"Zawartość ditlenku węgla, metanu i węglowodorów Ditlenek węgla","range":"(0,200 – 4,00) μmol/mol"},{"name":"Metan","range":"(10,0 – 200) μmol/mol"},{"name":"Węglowodory ogółem z wyłączeniem metanu (ekwiwalent C1)","range":"(0,100 – 4,00)"},{"name":"μmol/mol"}],"technique":"Metoda chromatografii gazowej z detektorem termokonduktometrycznym (GC-TCD); Metoda chromatografii gazowej z detektorem płomieniowo – jonizacyjnym i termokonduktometrycznym (GC-FID/TCD)","techniques":["Metoda chromatografii gazowej z detektorem termokonduktometrycznym (GC-TCD)","Metoda chromatografii gazowej z detektorem płomieniowo – jonizacyjnym i termokonduktometrycznym (GC-FID/TCD)"],"computed":[],"activity":"Zawartość helu\nZakres:\nZakres (25,0 – 600) μmol/mol\nZawartość ditlenku węgla, metanu i węglowodorów Ditlenek węgla (0,200 – 4,00) μmol/mol\nMetan (10,0 – 200) μmol/mol\nWęglowodory ogółem z wyłączeniem metanu (ekwiwalent C1) (0,100 – 4,00)\nμmol/mol\nMetoda chromatografii gazowej z detektorem termokonduktometrycznym (GC-TCD); Metoda chromatografii gazowej z detektorem płomieniowo – jonizacyjnym i termokonduktometrycznym (GC-FID/TCD)","reference":"NPL Report AS64:2011-08 p. 4.2.4 (a) | Instrukcja IT-M/TT1/99 wydanie 1 z dnia 04.06.2024 NPL Report AS64:2011-08 p. 4.2.7 (a), p. 4.2.2 (a) | Instrukcja IT-M/TT1/99 wydanie 1 z dnia 04.06.2024","norm_bases":["NPL Report AS64:2011-08 p. 4.2.4 (a)","Instrukcja IT-M/TT1/99 wydanie 1 z dnia 04.06.2024 NPL Report AS64:2011-08 p. 4.2.7 (a), p. 4.2.2 (a)","Instrukcja IT-M/TT1/99 wydanie 1 z dnia 04.06.2024"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: wodór (automotive) Zawartość helu\nZakres:\nZakres (25,0 – 600) μmol/mol\nZawartość ditlenku węgla, metanu i węglowodorów Ditlenek węgla (0,200 – 4,00) μmol/mol\nMetan (10,0 – 200) μmol/mol\nWęglowodory ogółem z wyłączeniem metanu (ekwiwalent C1) (0,100 – 4,00)\nμmol/mol\nMetoda chromatografii gazowej z detektorem termokonduktometrycznym (GC-TCD); Metoda chromatografii gazowej z detektorem płomieniowo – jonizacyjnym i termokonduktometrycznym (GC-FID/TCD) NPL Report AS64:2011-08 p. 4.2.4 (a) | Instrukcja IT-M/TT1/99 wydanie 1 z dnia 04.06.2024 NPL Report AS64:2011-08 p. 4.2.7 (a), p. 4.2.2 (a) | Instrukcja IT-M/TT1/99 wydanie 1 z dnia 04.06.2024 Paliwa gazowe: wodor (automotive) Zawartosc helu\nZakres:\nZakres (25,0 – 600) μmol/mol\nZawartosc ditlenku wegla, metanu i weglowodorow Ditlenek wegla (0,200 – 4,00) μmol/mol\nMetan (10,0 – 200) μmol/mol\nWeglowodory ogolem z wylaczeniem metanu (ekwiwalent C1) (0,100 – 4,00)\nμmol/mol\nMetoda chromatografii gazowej z detektorem termokonduktometrycznym (GC-TCD); Metoda chromatografii gazowej z detektorem plomieniowo – jonizacyjnym i termokonduktometrycznym (GC-FID/TCD) NPL Report AS64:2011-08 p. 4.2.4 (a) | Instrukcja IT-M/TT1/99 wydanie 1 z dnia 04.06.2024 NPL Report AS64:2011-08 p. 4.2.7 (a), p. 4.2.2 (a) | Instrukcja IT-M/TT1/99 wydanie 1 z dnia 04.06.2024","categories":["petro","automotive"],"row_index":660,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb7da","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: wodór (automotive)","methodology":"Zawartość siarkowodoru, siarczku karbonylu i siarczku dimetylu","parameters":[{"name":"Siarkowodór","range":"(0,00050 – 0,0040)"},{"name":"μmol/mol Siarczek karbonylu","range":"(0,00050 – 0,0040)"},{"name":"μmol/mol Siarczek dimetylu","range":"(0,00050 – 0,0040)"},{"name":"μmol/mol Związki siarki ogólem (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detektorem chemiluminescencyjnym (GC-SCD)","techniques":["Metoda chromatografii gazowej z detektorem chemiluminescencyjnym (GC-SCD)"],"computed":[],"activity":"Zawartość siarkowodoru, siarczku karbonylu i siarczku dimetylu\nZakres:\nSiarkowodór (0,00050 – 0,0040)\nμmol/mol Siarczek karbonylu (0,00050 – 0,0040)\nμmol/mol Siarczek dimetylu (0,00050 – 0,0040)\nμmol/mol Związki siarki ogólem (z obliczeń)\nMetoda chromatografii gazowej z detektorem chemiluminescencyjnym (GC-SCD)","reference":"ASTM D 7652-11","norm_bases":["ASTM D 7652-11"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: wodór (automotive) Zawartość siarkowodoru, siarczku karbonylu i siarczku dimetylu\nZakres:\nSiarkowodór (0,00050 – 0,0040)\nμmol/mol Siarczek karbonylu (0,00050 – 0,0040)\nμmol/mol Siarczek dimetylu (0,00050 – 0,0040)\nμmol/mol Związki siarki ogólem (z obliczeń)\nMetoda chromatografii gazowej z detektorem chemiluminescencyjnym (GC-SCD) ASTM D 7652-11 Paliwa gazowe: wodor (automotive) Zawartosc siarkowodoru, siarczku karbonylu i siarczku dimetylu\nZakres:\nSiarkowodor (0,00050 – 0,0040)\nμmol/mol Siarczek karbonylu (0,00050 – 0,0040)\nμmol/mol Siarczek dimetylu (0,00050 – 0,0040)\nμmol/mol Zwiazki siarki ogolem (z obliczen)\nMetoda chromatografii gazowej z detektorem chemiluminescencyjnym (GC-SCD) ASTM D 7652-11","categories":["petro","automotive"],"row_index":661,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb7db","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: wodór (automotive)","methodology":"Zawartość formaldehydu i halogenków organicznych","parameters":[{"name":"Formaldehyd","range":"(0,050 – 0,40) μmol/mol"},{"name":"Zakres","range":"1,2 – dichlorobenzen (0,0010 – 0,050)"},{"name":"μmol/mol Chloroform","range":"(0,0010 – 0,050) μmol/mol"},{"name":"Dichlorometan","range":"(0,0010 – 0,050)"},{"name":"μmol/mol Tetrachloroetylen","range":"(0,0010 – 0,050)"},{"name":"μmol/mol Zawartość związków halogenowych ogółem (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detektorem mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detektorem mas (GC-MS)"],"computed":[],"activity":"Zawartość formaldehydu i halogenków organicznych\nZakres:\nFormaldehyd (0,050 – 0,40) μmol/mol\nZakres 1,2 – dichlorobenzen (0,0010 – 0,050)\nμmol/mol Chloroform (0,0010 – 0,050) μmol/mol\nDichlorometan (0,0010 – 0,050)\nμmol/mol Tetrachloroetylen (0,0010 – 0,050)\nμmol/mol Zawartość związków halogenowych ogółem (z obliczeń)\nMetoda chromatografii gazowej z detektorem mas (GC-MS)","reference":"ASTM D 7892-25","norm_bases":["ASTM D 7892-25"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: wodór (automotive) Zawartość formaldehydu i halogenków organicznych\nZakres:\nFormaldehyd (0,050 – 0,40) μmol/mol\nZakres 1,2 – dichlorobenzen (0,0010 – 0,050)\nμmol/mol Chloroform (0,0010 – 0,050) μmol/mol\nDichlorometan (0,0010 – 0,050)\nμmol/mol Tetrachloroetylen (0,0010 – 0,050)\nμmol/mol Zawartość związków halogenowych ogółem (z obliczeń)\nMetoda chromatografii gazowej z detektorem mas (GC-MS) ASTM D 7892-25 Paliwa gazowe: wodor (automotive) Zawartosc formaldehydu i halogenkow organicznych\nZakres:\nFormaldehyd (0,050 – 0,40) μmol/mol\nZakres 1,2 – dichlorobenzen (0,0010 – 0,050)\nμmol/mol Chloroform (0,0010 – 0,050) μmol/mol\nDichlorometan (0,0010 – 0,050)\nμmol/mol Tetrachloroetylen (0,0010 – 0,050)\nμmol/mol Zawartosc zwiazkow halogenowych ogolem (z obliczen)\nMetoda chromatografii gazowej z detektorem mas (GC-MS) ASTM D 7892-25","categories":["petro","automotive"],"row_index":662,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb7dc","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: wodór (automotive)","methodology":"Zawartość argonu, azotu, tlenu, tlenku węgla","parameters":[{"name":"Argon","range":"(50,0 – 600) μmol/mol"},{"name":"Azot","range":"(50,0 – 600) μmol/mol"},{"name":"Tlen","range":"(3,0 – 40) μmol/mol"},{"name":"Tlenek wegla","range":"(0,0500 – 0,400)"},{"name":"μmol/mol"}],"technique":"Metoda chromatografii gazowej z detektorem wyładowań helowych (GC-PDHID)","techniques":["Metoda chromatografii gazowej z detektorem wyładowań helowych (GC-PDHID)"],"computed":[],"activity":"Zawartość argonu, azotu, tlenu, tlenku węgla\nZakres:\nArgon (50,0 – 600) μmol/mol\nAzot (50,0 – 600) μmol/mol\nTlen (3,0 – 40) μmol/mol\nTlenek wegla (0,0500 – 0,400)\nμmol/mol\nMetoda chromatografii gazowej z detektorem wyładowań helowych (GC-PDHID)","reference":"NPL Report AS64:2011-08 p.4.2.6 (b), p.4.2.5 (a), p. 4.2.3 (a), p. 4.2.8 (a) | Instrukcja IT-M/TT1/97 wydanie 1 z dnia 24.05.2024","norm_bases":["NPL Report AS64:2011-08 p.4.2.6 (b), p.4.2.5 (a), p. 4.2.3 (a), p. 4.2.8 (a)","Instrukcja IT-M/TT1/97 wydanie 1 z dnia 24.05.2024"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: wodór (automotive) Zawartość argonu, azotu, tlenu, tlenku węgla\nZakres:\nArgon (50,0 – 600) μmol/mol\nAzot (50,0 – 600) μmol/mol\nTlen (3,0 – 40) μmol/mol\nTlenek wegla (0,0500 – 0,400)\nμmol/mol\nMetoda chromatografii gazowej z detektorem wyładowań helowych (GC-PDHID) NPL Report AS64:2011-08 p.4.2.6 (b), p.4.2.5 (a), p. 4.2.3 (a), p. 4.2.8 (a) | Instrukcja IT-M/TT1/97 wydanie 1 z dnia 24.05.2024 Paliwa gazowe: wodor (automotive) Zawartosc argonu, azotu, tlenu, tlenku wegla\nZakres:\nArgon (50,0 – 600) μmol/mol\nAzot (50,0 – 600) μmol/mol\nTlen (3,0 – 40) μmol/mol\nTlenek wegla (0,0500 – 0,400)\nμmol/mol\nMetoda chromatografii gazowej z detektorem wyladowan helowych (GC-PDHID) NPL Report AS64:2011-08 p.4.2.6 (b), p.4.2.5 (a), p. 4.2.3 (a), p. 4.2.8 (a) | Instrukcja IT-M/TT1/97 wydanie 1 z dnia 24.05.2024","categories":["petro","automotive"],"row_index":663,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb7dd","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: wodór (automotive)","methodology":"Zawartość kwasu mrówkowego, amoniaku","parameters":[{"name":"Kwas mrówkowy","range":"(0,030 – 4,0)"},{"name":"μmol/mol Amoniak","range":"(0,020 – 4,0) μmol/mol"}],"technique":"Metoda chromatografii jonowej z detektorem konduktometrycznym (IC-CD)","techniques":["Metoda chromatografii jonowej z detektorem konduktometrycznym (IC-CD)"],"computed":[],"activity":"Zawartość kwasu mrówkowego, amoniaku\nZakres:\nKwas mrówkowy (0,030 – 4,0)\nμmol/mol Amoniak (0,020 – 4,0) μmol/mol\nMetoda chromatografii jonowej z detektorem konduktometrycznym (IC-CD)","reference":"JIS K0127:2013 | Instrukcja IT-M/TT1/102 wydanie 1 z dnia 24.06.2024","norm_bases":["JIS K0127:2013","Instrukcja IT-M/TT1/102 wydanie 1 z dnia 24.06.2024"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: wodór (automotive) Zawartość kwasu mrówkowego, amoniaku\nZakres:\nKwas mrówkowy (0,030 – 4,0)\nμmol/mol Amoniak (0,020 – 4,0) μmol/mol\nMetoda chromatografii jonowej z detektorem konduktometrycznym (IC-CD) JIS K0127:2013 | Instrukcja IT-M/TT1/102 wydanie 1 z dnia 24.06.2024 Paliwa gazowe: wodor (automotive) Zawartosc kwasu mrowkowego, amoniaku\nZakres:\nKwas mrowkowy (0,030 – 4,0)\nμmol/mol Amoniak (0,020 – 4,0) μmol/mol\nMetoda chromatografii jonowej z detektorem konduktometrycznym (IC-CD) JIS K0127:2013 | Instrukcja IT-M/TT1/102 wydanie 1 z dnia 24.06.2024","categories":["petro","automotive"],"row_index":664,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb7de","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: wodór (automotive)","methodology":"Zawartość cząstek stałych","parameters":[{"name":"Zakres","range":"(0,0500 – 5,00) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość cząstek stałych\nZakres (0,0500 – 5,00) mg/kg\nMetoda wagowa","reference":"ASTM D 7651-24e1","norm_bases":["ASTM D 7651-24e1"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: wodór (automotive) Zawartość cząstek stałych\nZakres (0,0500 – 5,00) mg/kg\nMetoda wagowa ASTM D 7651-24e1 Paliwa gazowe: wodor (automotive) Zawartosc czastek stalych\nZakres (0,0500 – 5,00) mg/kg\nMetoda wagowa ASTM D 7651-24e1","categories":["petro","automotive"],"row_index":665,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb7df","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: wodór (automotive)","methodology":"Indeks paliwa wodorowego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Indeks paliwa wodorowego (z obliczeń)","reference":"ISO 14687:2019-11 p. 5.1","norm_bases":["ISO 14687:2019-11 p. 5.1"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: wodór (automotive) Indeks paliwa wodorowego (z obliczeń) ISO 14687:2019-11 p. 5.1 Paliwa gazowe: wodor (automotive) Indeks paliwa wodorowego (z obliczen) ISO 14687:2019-11 p. 5.1","categories":["petro","automotive"],"row_index":666,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a98c27b2047650df5dfb7e0","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: wodór (automotive)","methodology":"Całkowita zawartość gazów innych niż wodór (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Całkowita zawartość gazów innych niż wodór (z obliczeń)","reference":"ISO 14687:2019-11 p. 5.1","norm_bases":["ISO 14687:2019-11 p. 5.1"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: wodór (automotive) Całkowita zawartość gazów innych niż wodór (z obliczeń) ISO 14687:2019-11 p. 5.1 Paliwa gazowe: wodor (automotive) Calkowita zawartosc gazow innych niz wodor (z obliczen) ISO 14687:2019-11 p. 5.1","categories":["petro","automotive"],"row_index":667,"parse_version":4,"parse_source":"agent-claude-code"}],"has_pdf":true}