{"lab":{"_id":"69ad52a3de79e566650fb263","accr_number":"AB 484","country":"PL","accr_body":"PCA","address":"ul. Chemików 7, 09-411 Płock","categories":["petro","water","environment","materials","automotive","construction"],"city":"Płock","imported_at":"2026-03-08T10:42:43.265Z","methods_count":668,"name":"ORLEN LABORATORIUM S.A.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_484.pdf"],"scope_summary":"","search_text":"orlen laboratorium s.a. ul. chemików 7, 09-411 płock water pharma electronics other petro food environment materials automotive metrology construction","status":"active","updated_at":"2026-03-08T14:51:19.823Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-17T20:31:52.896Z","location":{"type":"Point","coordinates":[19.7065,52.5463]},"email_confidence":"low","email_mx":false,"email_source":"https://www.pca.gov.pl/akredytowane-podmioty/akredytacje-aktywne/laboratoria-badawcze/AB%20484,podmiot.html","needs_review":true,"review_reason":"domena bez MX — zweryfikuj","fields_of_testing":[{"codes":"C/10/P; C/28/P; C/29/P; C/30/P","pl":"Badania chemiczne i pobieranie próbek paliw ciekłych, paliw gazowych, wody, wody do spożycia przez ludzi, ścieków","en":"Chemical tests and sampling of aliquid fuels, gas fuels, water, water for human consumption, sewage"},{"codes":"C/33/P","pl":"Badania chemiczne i pobieranie próbek – środowisko pracy (czynniki szkodliwe - powietrze)","en":"Chemical tests and sampling - working environment (harmful factors - air)"},{"codes":"C/4; C/5; C/9; C/31; C/32; C/36; C/46; C/47; C/48","pl":"Badania chemiczne wyrobów chemicznych, materiałów budowlanych, powietrza, gleby, odpadów, gazów odlotowych, materiałów smarnych, ropy naftowej, innych przetworów naftowych","en":"Chemical tests and sampling of chemical products, building materials, air, soil, waste, waste gases, lubricants, crude oil, other petroluem products"},{"codes":"G/33","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki szkodliwe i uciążliwe – oświetlenie, pole elektromagnetyczne, mikroklimat, drgania, hałas w środowisku pracy)","en":"Tests concerning environmental engineering (environmental and climatic) – working environment (harmful and nuisance factors – lighting, electromagnetic field, microclimate, vibration, noise in working envionment)"},{"codes":"N/10/P; N/28/P; N/29/P; N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek paliw ciekłych, paliw gazowych, wody, wody do spożycia przez ludzi, ścieków","en":"Tests of physical properties and sampling of liquid fuels, gas fuels, water, drinking water, sewage"},{"codes":"N/33/P","pl":"Badania właściwości fizycznych i pobieranie próbek – środowisko pracy (czynniki szkodliwe - powietrze)","en":"Tests of physical properties and sampling - working environment (harmful factors - air)"},{"codes":"N/4; N/5; N/31; N/32; N/46; N/47; N/48","pl":"Badania właściwości fizycznych wyrobów chemicznych, materiałów budowlanych, gleby, osadów, materiałów smarnych, ropy naftowej, innych przetworów naftowych","en":"Tests of physical properties of chemical products, building materials, soil, sediments, lubricants, crude oil, other petroleum products"},{"codes":"Q/10/P","pl":"Badania sensoryczne i pobieranie próbek paliw gazowych","en":"Sensory tests and sampling of gas fuels"},{"codes":"28/P; 29/P","pl":"Pobieranie próbek wody i wody do spożycia do badań mikrobiologicznych","en":"Sampling of water and water for human consumption for microbiological testing"}],"issue":{"no":"52","date":"30.07.2026"},"parse_date":"2026-08-17T20:31:52.896Z","parse_source":"agent-claude-code","map_coord":[52.586402,19.653731],"map_geo":"nominatim-street","lab_locations":[{"name":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","address":"ul. Chemików 7, 09-411 Płock","city":"Płock","postal":"09-411"},{"name":"Pracownia Paliw i Aromatów PP1","address":"ul. Chemików 7, 09-411 Płock","city":"Płock","postal":"09-411"},{"name":"Pracownia Przerobu Ropy PP2","address":"ul. Chemików 7, 09-411 Płock","city":"Płock","postal":"09-411"},{"name":"Pracownia Środowiska Pracy PP8","address":"ul. Chemików 7, 09-411 Płock","city":"Płock","postal":"09-411"},{"name":"Pracownia Chromatografii PP3","address":"ul. Chemików 7, 09-411 Płock","city":"Płock","postal":"09-411"},{"name":"Zespół Logistyki Płock LL/P","address":"ul. Chemików 7, 09-411 Płock","city":"Płock","postal":"09-411"},{"name":"Zespół Logistyki Włocławek LL/W","address":"ul. Toruńska 222, 87-800 Włocławek","city":"Włocławek","postal":"87-800"},{"name":"Pracownia PTA TT5","address":"ul. Krzywa Góra 13/15/17, 87-800 Włocławek","city":"Włocławek","postal":"87-800"},{"name":"Punkt Obsługi Laboratoryjnej we Wrocławiu PP7/5","address":"ul. Swojczycka 44, 51-501 Wrocław","city":"Wrocław","postal":"51-501"},{"name":"Pracownia Produktów Rafineryjnych w Trzebini PP6","address":"ul. Fabryczna 22, 32-540 Trzebinia","city":"Trzebinia","postal":"32-540"},{"name":"Pracownia Produktów Naftowych w Jedliczu PP5","address":"ul. Trzecieskiego 14, 38-460 Jedlicze","city":"Jedlicze","postal":"38-460"},{"name":"Punkt Obsługi Laboratoryjnej w Ostrowie Wielkopolskim PP7/3","address":"ul. Węglowa 1, 63-400 Ostrów Wielkopolski","city":"Ostrów Wielkopolski","postal":"63-400"},{"name":"Punkt Obsługi Laboratoryjnej w Lublinie PP7/1","address":"ul. Zemborzycka 116 B, 20-445 Lublin","city":"Lublin","postal":"20-445"},{"name":"Punkt Obsługi Laboratoryjnej w Olsztynie PP7/2","address":"ul. Gutkowo 54, 11-041 Olsztyn","city":"Olsztyn","postal":"11-041"},{"name":"Punkt Obsługi Laboratoryjnej w Warszawie PP7/4","address":"ul. Estrady 8, 05-080 Izabelin","city":"Izabelin","postal":"05-080"},{"name":"Pracownia Nawozów i Środowiska Naturalnego TT1","address":"ul. Toruńska 222, 87-800 Włocławek","city":"Włocławek","postal":"87-800"},{"name":"Pracownia Produktów Na ftowych w Jedliczu PP5","address":null,"city":null,"postal":null},{"name":"Pracownia Prze robu Ropy PP2","address":null,"city":null,"postal":null},{"name":"Pracownia Wód, Ścieków i Prod uktów Petrochemicznych PP4","address":null,"city":null,"postal":null},{"name":"Pracownia Środo wiska Pracy PP8","address":null,"city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/645276012d863a635cc569edbef0eb90/AB%20484.pdf","has_en":true,"category_counts":{"petro":402,"water":158,"environment":100,"materials":61,"other":41,"automotive":22,"construction":8,"microbiology":1},"category_scores":{"petro":203.79,"water":31.48,"environment":12.61,"materials":4.69,"other":2.12,"automotive":0.61,"construction":0.08,"microbiology":0},"has_zh":true},"methods":[{"_id":"6a836fb9af14b9c0e7b1eb17","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie: węgla ogólnego (TC), ogólnego węgla organicznego (TOC)","parameters":[{"name":"Zakres","range":"(0,30 – 1000) mg/l"},{"name":"Stężenie ogólnego węgla nieorganicznego (TIC)"},{"name":"Zakres","range":"(1,00 – 10,0) mg/l"}],"technique":"Metoda spektrometrii w zakresie podczerwieni IR","techniques":["Metoda spektrometrii w zakresie podczerwieni IR"],"computed":[],"activity":"Stężenie: węgla ogólnego (TC), ogólnego węgla organicznego (TOC)\nZakres:\nZakres (0,30 – 1000) mg/l\nStężenie ogólnego węgla nieorganicznego (TIC)\nZakres (1,00 – 10,0) mg/l\nMetoda spektrometrii w zakresie podczerwieni IR","reference":"PN-EN 1484:1999","norm_bases":["PN-EN 1484:1999"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie: węgla ogólnego (TC), ogólnego węgla organicznego (TOC)\nZakres:\nZakres (0,30 – 1000) mg/l\nStężenie ogólnego węgla nieorganicznego (TIC)\nZakres (1,00 – 10,0) mg/l\nMetoda spektrometrii w zakresie podczerwieni IR PN-EN 1484:1999 Woda, scieki Stezenie: wegla ogolnego (TC), ogolnego wegla organicznego (TOC)\nZakres:\nZakres (0,30 – 1000) mg/l\nStezenie ogolnego wegla nieorganicznego (TIC)\nZakres (1,00 – 10,0) mg/l\nMetoda spektrometrii w zakresie podczerwieni IR PN-EN 1484:1999","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of: total carbon (TC), total organic carbon (TOC)","parameters_en":[{"name":"Range","range":"(0,30 – 1000) mg/l"},{"name":"Total inorganic carbon (TIC) concentration"},{"name":"Range","range":"(1,00 – 10,0) mg/l"}],"search_en":"Water, wastewater Concentration of: total carbon (TC), total organic carbon (TOC) Spectrometry method in the infrared range IR Range Total inorganic carbon (TIC) concentration Range PN-EN 1484:1999","technique_en":"Spectrometry method in the infrared range IR","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,30 – 1000) mg/l"},{"name":"Stężenie ogólnego węgla nieorganicznego (TIC)"},{"name":"范围","range":"(1,00 – 10,0) mg/l"}],"search_zh":"水、废水 红外光谱法 IR 范围 范围 PN-EN 1484:1999","test_object_zh":"水、废水","technique_zh":"红外光谱法 IR"},{"_id":"6a836fb9af14b9c0e7b1eb18","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"10,0 μS/cm – 100 mS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres 10,0 μS/cm – 100 mS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Przewodność elektryczna właściwa\nZakres 10,0 μS/cm – 100 mS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, scieki Przewodnosc elektryczna wlasciwa\nZakres 10,0 μS/cm – 100 mS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"10,0 μS/cm – 100 mS/cm"}],"search_en":"Water, wastewater Electrical conductivity Conductometric method Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water, wastewater","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"10,0 μS/cm – 100 mS/cm"}],"search_zh":"水、废水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、废水"},{"_id":"6a836fb9af14b9c0e7b1eb19","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie siarczanów (VI)","parameters":[{"name":"Zakres","range":"(10 – 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie siarczanów (VI)\nZakres (10 – 1000) mg/l\nMetoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie siarczanów (VI)\nZakres (10 – 1000) mg/l\nMetoda wagowa PN-ISO 9280:2002 Woda, scieki Stezenie siarczanow (VI)\nZakres (10 – 1000) mg/l\nMetoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulphate (VI) concentration","parameters_en":[{"name":"Range","range":"(10 – 1000) mg/l"}],"search_en":"Water, wastewater Sulphate (VI) concentration Gravimetric method Range PN-ISO 9280:2002","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(10 – 1000) mg/l"}],"search_zh":"水、废水 硫酸盐(VI)浓度 重量法 范围 PN-ISO 9280:2002","technique_zh":"重量法","test_object_zh":"水、废水","methodology_zh":"硫酸盐(VI)浓度"},{"_id":"6a836fb9af14b9c0e7b1eb1a","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Indeks fenolowy","parameters":[{"name":"Zakres","range":"(0,010 – 10) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Indeks fenolowy\nZakres (0,010 – 10) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6439:1994","norm_bases":["PN-ISO 6439:1994"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Indeks fenolowy\nZakres (0,010 – 10) mg/l\nMetoda spektrofotometryczna PN-ISO 6439:1994 Woda, scieki Indeks fenolowy\nZakres (0,010 – 10) mg/l\nMetoda spektrofotometryczna PN-ISO 6439:1994","categories":["water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phenol index","parameters_en":[{"name":"Range","range":"(0,010 – 10) mg/l"}],"search_en":"Water, wastewater Phenol index Spectrophotometric method Range PN-ISO 6439:1994","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,010 – 10) mg/l"}],"search_zh":"水、废水 酚指数 分光光度法 范围 PN-ISO 6439:1994","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"酚指数"},{"_id":"6a836fb9af14b9c0e7b1eb1b","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu BZT5","parameters":[{"name":"Zakres","range":"(2 – 6000) mg O2/l"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu BZT5\nZakres (2 – 6000) mg O2/l\nMetoda optyczna","reference":"PN-EN ISO 5815-1 :2019-12","norm_bases":["PN-EN ISO 5815-1 :2019-12"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu BZT5\nZakres (2 – 6000) mg O2/l\nMetoda optyczna PN-EN ISO 5815-1 :2019-12 Woda, scieki Biochemiczne zapotrzebowanie tlenu BZT5\nZakres (2 – 6000) mg O2/l\nMetoda optyczna PN-EN ISO 5815-1 :2019-12","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand BOD5","parameters_en":[{"name":"Range","range":"(2 – 6000) mg O2/l"}],"search_en":"Water, wastewater Biochemical oxygen demand BOD5 Optical method Range PN-EN ISO 5815-1 :2019-12","technique_en":"Optical method","test_object_en":"Water, wastewater","methodology_zh":"生化需氧量 BZT5（BOD5）","parameters_zh":[{"name":"范围","range":"(2 – 6000) mg O2/l"}],"search_zh":"水、废水 生化需氧量 BZT5（BOD5） 光学法 范围 PN-EN ISO 5815-1 :2019-12","technique_zh":"光学法","test_object_zh":"水、废水"},{"_id":"6a836fb9af14b9c0e7b1eb1c","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie chromu (VI)","parameters":[{"name":"Zakres","range":"(2 – 20) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chromu (VI)\nZakres (2 – 20) μg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 18412:2007","norm_bases":["PN-EN ISO 18412:2007"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie chromu (VI)\nZakres (2 – 20) μg/l\nMetoda spektrofotometryczna PN-EN ISO 18412:2007 Woda Stezenie chromu (VI)\nZakres (2 – 20) μg/l\nMetoda spektrofotometryczna PN-EN ISO 18412:2007","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chromium(VI) concentration","parameters_en":[{"name":"Range","range":"(2 – 20) μg/l"}],"search_en":"Water Chromium(VI) concentration Spectrophotometric method Range PN-EN ISO 18412:2007","technique_en":"Spectrophotometric method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(2 – 20) μg/l"}],"search_zh":"水 六价铬浓度 分光光度法 范围 PN-EN ISO 18412:2007","technique_zh":"分光光度法","test_object_zh":"水","methodology_zh":"六价铬浓度"},{"_id":"6a836fb9af14b9c0e7b1eb1d","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie fosforu","parameters":[{"name":"Zakres","range":"(0,01 – 50) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu\nZakres (0,01 – 50) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010","norm_bases":["PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie fosforu\nZakres (0,01 – 50) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 Scieki Stezenie fosforu\nZakres (0,01 – 50) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,01 – 50) mg/l"}],"search_en":"Wastewater Phosphorus concentration Spectrophotometric method Range PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(0,01 – 50) mg/l"}],"search_zh":"污水 磷浓度 分光光度法 范围 PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010","technique_zh":"分光光度法","test_object_zh":"污水","methodology_zh":"磷浓度"},{"_id":"6a836fb9af14b9c0e7b1eb1e","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(10 – 5 000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (10 – 5 000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie chlorków\nZakres (10 – 5 000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Scieki Stezenie chlorkow\nZakres (10 – 5 000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(10 – 5 000) mg/l"}],"search_en":"Wastewater Chloride concentration Titrimetric method Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Wastewater","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(10 – 5 000) mg/l"}],"search_zh":"污水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"污水"},{"_id":"6a836fb9af14b9c0e7b1eb1f","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,040 – 5,00) mg/l"},{"name":"Stężenie amoniaku (jonu amonowego) Z obliczeń"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres:\nZakres (0,040 – 5,00) mg/l\nStężenie amoniaku (jonu amonowego) Z obliczeń\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu amonowego\nZakres:\nZakres (0,040 – 5,00) mg/l\nStężenie amoniaku (jonu amonowego) Z obliczeń\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Scieki Stezenie azotu amonowego\nZakres:\nZakres (0,040 – 5,00) mg/l\nStezenie amoniaku (jonu amonowego) Z obliczen\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,040 – 5,00) mg/l"},{"name":"Ammonia (ammonium ion) concentration Calculated"}],"search_en":"Wastewater Ammonium nitrogen concentration Spectrophotometric method Range Ammonia (ammonium ion) concentration Calculated PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,040 – 5,00) mg/l"},{"name":"Stężenie amoniaku (jonu amonowego) Z obliczeń"}],"search_zh":"污水 氨氮浓度 分光光度法 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a836fb9af14b9c0e7b1eb20","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(1,0 – 2000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (1,0 – 2000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Zawiesiny ogólne\nZakres (1,0 – 2000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Scieki Zawiesiny ogolne\nZakres (1,0 – 2000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(1,0 – 2000) mg/l"}],"search_en":"Wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Wastewater","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(1,0 – 2000) mg/l"}],"search_zh":"污水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"污水"},{"_id":"6a836fb9af14b9c0e7b1eb21","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(1,0 – 100) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (1,0 – 100) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu Kjeldahla\nZakres (1,0 – 100) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Scieki Stezenie azotu Kjeldahla\nZakres (1,0 – 100) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(1,0 – 100) mg/l"}],"search_en":"Wastewater Kjeldahl nitrogen concentration Titrimetric method Range PN-EN 25663:2001","technique_en":"Titrimetric method","test_object_en":"Wastewater","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(1,0 – 100) mg/l"}],"search_zh":"污水 凯氏氮浓度 滴定法 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"污水"},{"_id":"6a836fb9af14b9c0e7b1eb22","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"Chemiczne zapotrzebowanie tlenu (ChZT)","parameters":[{"name":"Zakres","range":"(10,0 – 10000) mg O2/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu (ChZT)\nZakres (10,0 – 10000) mg O2/l\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Chemiczne zapotrzebowanie tlenu (ChZT)\nZakres (10,0 – 10000) mg O2/l\nMetoda spektrofotometryczna PN-ISO 15705:2005 Scieki Chemiczne zapotrzebowanie tlenu (ChZT)\nZakres (10,0 – 10000) mg O2/l\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand (COD)","parameters_en":[{"name":"Range","range":"(10,0 – 10000) mg O2/l"}],"search_en":"Wastewater Chemical oxygen demand (COD) Spectrophotometric method Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(10,0 – 10000) mg O2/l"}],"search_zh":"污水 化学需氧量（COD） 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"污水","methodology_zh":"化学需氧量（COD）"},{"_id":"6a836fb9af14b9c0e7b1eb23","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Scieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"search_en":"Wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Wastewater","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"污水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"污水"},{"_id":"6a836fb9af14b9c0e7b1eb24","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu ogólnego (suma azotu Kjeldahla, azotu azotanowego i azotynowego) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu ogólnego (suma azotu Kjeldahla, azotu azotanowego i azotynowego) (z obliczeń)","reference":"Metoda nr 047 Wydanie 5 z dnia 19.11.2019","norm_bases":["Metoda nr 047 Wydanie 5 z dnia 19.11.2019"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu ogólnego (suma azotu Kjeldahla, azotu azotanowego i azotynowego) (z obliczeń) Metoda nr 047 Wydanie 5 z dnia 19.11.2019 Scieki Stezenie azotu ogolnego (suma azotu Kjeldahla, azotu azotanowego i azotynowego) (z obliczen) Metoda nr 047 Wydanie 5 z dnia 19.11.2019","categories":["water"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total nitrogen concentration (sum of Kjeldahl nitrogen, nitrate and nitrite nitrogen) (calculated)","search_en":"Wastewater Total nitrogen concentration (sum of Kjeldahl nitrogen, nitrate and nitrite nitrogen) (calculated) Metoda nr 047 Wydanie 5 z dnia 19.11.2019","test_object_en":"Wastewater","search_zh":"污水 Metoda nr 047 Wydanie 5 z dnia 19.11.2019","test_object_zh":"污水"},{"_id":"6a836fb9af14b9c0e7b1eb25","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie chromu +6","parameters":[{"name":"Zakres","range":"(0,01 – 1,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chromu +6\nZakres (0,01 – 1,00) mg/l\nMetoda spektrofotometryczna","reference":"PN-C-04604-08:1977","norm_bases":["PN-C-04604-08:1977"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie chromu +6\nZakres (0,01 – 1,00) mg/l\nMetoda spektrofotometryczna PN-C-04604-08:1977 Scieki Stezenie chromu +6\nZakres (0,01 – 1,00) mg/l\nMetoda spektrofotometryczna PN-C-04604-08:1977","categories":["water"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chromium +6 concentration","parameters_en":[{"name":"Range","range":"(0,01 – 1,00) mg/l"}],"search_en":"Wastewater Chromium +6 concentration Spectrophotometric method Range PN-C-04604-08:1977","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(0,01 – 1,00) mg/l"}],"search_zh":"污水 六价铬浓度 分光光度法 范围 PN-C-04604-08:1977","technique_zh":"分光光度法","test_object_zh":"污水","methodology_zh":"六价铬浓度"},{"_id":"6a836fb9af14b9c0e7b1eb26","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,010 – 10,0) mg/l"},{"name":"Stężenie azotynów (z obliczeń)"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres:\nZakres (0,010 – 10,0) mg/l\nStężenie azotynów (z obliczeń)\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu azotynowego\nZakres:\nZakres (0,010 – 10,0) mg/l\nStężenie azotynów (z obliczeń)\nMetoda spektrofotometryczna PN-EN 26777:1999 Scieki Stezenie azotu azotynowego\nZakres:\nZakres (0,010 – 10,0) mg/l\nStezenie azotynow (z obliczen)\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,010 – 10,0) mg/l"},{"name":"Nitrite concentration (calculated)"}],"search_en":"Wastewater Nitrite nitrogen concentration Spectrophotometric method Range Nitrite concentration (calculated) PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,010 – 10,0) mg/l"},{"name":"亚硝酸盐浓度（由计算得出）"}],"search_zh":"污水 亚硝态氮浓度 分光光度法 范围 亚硝酸盐浓度（由计算得出） PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a836fb9af14b9c0e7b1eb27","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie substancji organicznych ekstrahujących się eterem naftowym","parameters":[{"name":"Zakres","range":"(2,0 – 420) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie substancji organicznych ekstrahujących się eterem naftowym\nZakres (2,0 – 420) mg/l\nMetoda wagowa","reference":"Metoda nr 115 wydanie 4 z dnia 18.12.2020","norm_bases":["Metoda nr 115 wydanie 4 z dnia 18.12.2020"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie substancji organicznych ekstrahujących się eterem naftowym\nZakres (2,0 – 420) mg/l\nMetoda wagowa Metoda nr 115 wydanie 4 z dnia 18.12.2020 Scieki Stezenie substancji organicznych ekstrahujacych sie eterem naftowym\nZakres (2,0 – 420) mg/l\nMetoda wagowa Metoda nr 115 wydanie 4 z dnia 18.12.2020","categories":["water"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of organic substances extractable with petroleum ether","parameters_en":[{"name":"Range","range":"(2,0 – 420) mg/l"}],"search_en":"Wastewater Concentration of organic substances extractable with petroleum ether Gravimetric method Range Metoda nr 115 wydanie 4 z dnia 18.12.2020","technique_en":"Gravimetric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(2,0 – 420) mg/l"}],"search_zh":"污水 石油醚可萃取有机物质浓度 重量法 范围 Metoda nr 115 wydanie 4 z dnia 18.12.2020","technique_zh":"重量法","test_object_zh":"污水","methodology_zh":"石油醚可萃取有机物质浓度"},{"_id":"6a836fb9af14b9c0e7b1eb28","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"Sucha pozostałość, pozostałość po prażeniu oraz substancje rozpuszczone","parameters":[{"name":"Zakres","range":"(10 – 10000) mg/l"},{"name":"Straty przy prażeniu (z obliczeń)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha pozostałość, pozostałość po prażeniu oraz substancje rozpuszczone\nZakres:\nZakres (10 – 10000) mg/l\nStraty przy prażeniu (z obliczeń)\nMetoda wagowa","reference":"Metoda nr 124 wydanie 2 z dnia 03.06.2020 r.","norm_bases":["Metoda nr 124 wydanie 2 z dnia 03.06.2020 r."],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Sucha pozostałość, pozostałość po prażeniu oraz substancje rozpuszczone\nZakres:\nZakres (10 – 10000) mg/l\nStraty przy prażeniu (z obliczeń)\nMetoda wagowa Metoda nr 124 wydanie 2 z dnia 03.06.2020 r. Scieki Sucha pozostalosc, pozostalosc po prazeniu oraz substancje rozpuszczone\nZakres:\nZakres (10 – 10000) mg/l\nStraty przy prazeniu (z obliczen)\nMetoda wagowa Metoda nr 124 wydanie 2 z dnia 03.06.2020 r.","categories":["water"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry residue, residue on ignition and dissolved solids","parameters_en":[{"name":"Range","range":"(10 – 10000) mg/l"},{"name":"Loss on ignition (calculated)"}],"search_en":"Wastewater Dry residue, residue on ignition and dissolved solids Gravimetric method Range Loss on ignition (calculated) Metoda nr 124 wydanie 2 z dnia 03.06.2020 r.","technique_en":"Gravimetric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(10 – 10000) mg/l"},{"name":"Straty przy prażeniu (z obliczeń)"}],"search_zh":"污水 重量法 范围 Metoda nr 124 wydanie 2 z dnia 03.06.2020 r.","technique_zh":"重量法","test_object_zh":"污水"},{"_id":"6a836fb9af14b9c0e7b1eb29","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu azotanowego","parameters":[{"name":"Zakres","range":"(0,010 – 30,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotanowego\nZakres (0,010 – 30,0) mg/l\nMetoda spektrofotometryczna","reference":"Metoda nr 125 wydanie 2 z dnia 16.07.2020 r.","norm_bases":["Metoda nr 125 wydanie 2 z dnia 16.07.2020 r."],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu azotanowego\nZakres (0,010 – 30,0) mg/l\nMetoda spektrofotometryczna Metoda nr 125 wydanie 2 z dnia 16.07.2020 r. Scieki Stezenie azotu azotanowego\nZakres (0,010 – 30,0) mg/l\nMetoda spektrofotometryczna Metoda nr 125 wydanie 2 z dnia 16.07.2020 r.","categories":["water"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,010 – 30,0) mg/l"}],"search_en":"Wastewater Nitrate nitrogen concentration Spectrophotometric method Range Metoda nr 125 wydanie 2 z dnia 16.07.2020 r.","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,010 – 30,0) mg/l"}],"search_zh":"污水 硝态氮浓度 分光光度法 范围 Metoda nr 125 wydanie 2 z dnia 16.07.2020 r.","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a836fb9af14b9c0e7b1eb2a","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie siarczków","parameters":[{"name":"Zakres","range":"(0,10 – 1,50) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie siarczków\nZakres (0,10 – 1,50) mg/l\nMetoda spektrofotometryczna","reference":"Metoda nr 179 wydanie 3 z dnia 13.12.2023 r.","norm_bases":["Metoda nr 179 wydanie 3 z dnia 13.12.2023 r."],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie siarczków\nZakres (0,10 – 1,50) mg/l\nMetoda spektrofotometryczna Metoda nr 179 wydanie 3 z dnia 13.12.2023 r. Scieki Stezenie siarczkow\nZakres (0,10 – 1,50) mg/l\nMetoda spektrofotometryczna Metoda nr 179 wydanie 3 z dnia 13.12.2023 r.","categories":["water"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfide concentration","parameters_en":[{"name":"Range","range":"(0,10 – 1,50) mg/l"}],"search_en":"Wastewater Sulfide concentration Spectrophotometric method Range Metoda nr 179 wydanie 3 z dnia 13.12.2023 r.","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(0,10 – 1,50) mg/l"}],"search_zh":"污水 硫化物浓度 分光光度法 范围 Metoda nr 179 wydanie 3 z dnia 13.12.2023 r.","technique_zh":"分光光度法","test_object_zh":"污水","methodology_zh":"硫化物浓度"},{"_id":"6a836fb9af14b9c0e7b1eb2b","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(1,0 – 20) mg/l"},{"name":"Stężenie amoniaku (jonu amonowego) (z obliczeń)"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres:\nZakres (1,0 – 20) mg/l\nStężenie amoniaku (jonu amonowego) (z obliczeń)\nMetoda miareczkowa","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu amonowego\nZakres:\nZakres (1,0 – 20) mg/l\nStężenie amoniaku (jonu amonowego) (z obliczeń)\nMetoda miareczkowa PN-ISO 5664:2002 Scieki Stezenie azotu amonowego\nZakres:\nZakres (1,0 – 20) mg/l\nStezenie amoniaku (jonu amonowego) (z obliczen)\nMetoda miareczkowa PN-ISO 5664:2002","categories":["water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(1,0 – 20) mg/l"},{"name":"Ammonia (ammonium ion) concentration (calculated)"}],"search_en":"Wastewater Ammonium nitrogen concentration Titrimetric method Range Ammonia (ammonium ion) concentration (calculated) PN-ISO 5664:2002","technique_en":"Titrimetric method","test_object_en":"Wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(1,0 – 20) mg/l"},{"name":"Stężenie amoniaku (jonu amonowego) (z obliczeń)"}],"search_zh":"污水 氨氮浓度 滴定法 范围 PN-ISO 5664:2002","technique_zh":"滴定法","test_object_zh":"污水"},{"_id":"6a836fb9af14b9c0e7b1eb2c","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Zawartość substancji ekstrahujących się dichlorometanem","parameters":[{"name":"Zakres","range":"(0,10 – 20,0) %m/m"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość substancji ekstrahujących się dichlorometanem\nZakres (0,10 – 20,0) %m/m\nMetoda wagowa","reference":"Metoda 106 Wydanie 3 z dnia 21.12.2020","norm_bases":["Metoda 106 Wydanie 3 z dnia 21.12.2020"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Zawartość substancji ekstrahujących się dichlorometanem\nZakres (0,10 – 20,0) %m/m\nMetoda wagowa Metoda 106 Wydanie 3 z dnia 21.12.2020 Osady sciekowe Zawartosc substancji ekstrahujacych sie dichlorometanem\nZakres (0,10 – 20,0) %m/m\nMetoda wagowa Metoda 106 Wydanie 3 z dnia 21.12.2020","categories":["water"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of substances extractable with dichloromethane","parameters_en":[{"name":"Range","range":"(0,10 – 20,0) %m/m"}],"search_en":"Sewage sludge Content of substances extractable with dichloromethane Gravimetric method Range Metoda 106 Wydanie 3 z dnia 21.12.2020","technique_en":"Gravimetric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(0,10 – 20,0) %m/m"}],"search_zh":"污泥 重量法 范围 Metoda 106 Wydanie 3 z dnia 21.12.2020","technique_zh":"重量法","test_object_zh":"污泥"},{"_id":"6a836fb9af14b9c0e7b1eb2d","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Sucha pozostałość","parameters":[{"name":"Zakres","range":"(0,8 – 48,0) %"},{"name":"Zawartość wody (z obliczeń)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha pozostałość\nZakres:\nZakres (0,8 – 48,0) %\nZawartość wody (z obliczeń)\nMetoda wagowa","reference":"PN-EN 15934:2013-02 Metoda A","norm_bases":["PN-EN 15934:2013-02 Metoda A"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Sucha pozostałość\nZakres:\nZakres (0,8 – 48,0) %\nZawartość wody (z obliczeń)\nMetoda wagowa PN-EN 15934:2013-02 Metoda A Osady sciekowe Sucha pozostalosc\nZakres:\nZakres (0,8 – 48,0) %\nZawartosc wody (z obliczen)\nMetoda wagowa PN-EN 15934:2013-02 Metoda A","categories":["water"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry residue","parameters_en":[{"name":"Range","range":"(0,8 – 48,0) %"},{"name":"Water content (calculated)"}],"search_en":"Sewage sludge Dry residue Gravimetric method Range Water content (calculated) PN-EN 15934:2013-02 Metoda A","technique_en":"Gravimetric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(0,8 – 48,0) %"},{"name":"水分含量（计算值）"}],"search_zh":"污泥 干残渣 重量法 范围 水分含量（计算值） PN-EN 15934:2013-02 Metoda A","technique_zh":"重量法","test_object_zh":"污泥","methodology_zh":"干残渣"},{"_id":"6a836fb9af14b9c0e7b1eb2e","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Straty przy prażeniu suchej masy","parameters":[{"name":"Zakres","range":"(7,0 – 85,0)%"},{"name":"Pozostałość po prażeniu suchej masy (z obliczeń)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Straty przy prażeniu suchej masy\nZakres:\nZakres (7,0 – 85,0)%\nPozostałość po prażeniu suchej masy (z obliczeń)\nMetoda wagowa","reference":"PN-EN 15935:2022-01","norm_bases":["PN-EN 15935:2022-01"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Straty przy prażeniu suchej masy\nZakres:\nZakres (7,0 – 85,0)%\nPozostałość po prażeniu suchej masy (z obliczeń)\nMetoda wagowa PN-EN 15935:2022-01 Osady sciekowe Straty przy prazeniu suchej masy\nZakres:\nZakres (7,0 – 85,0)%\nPozostalosc po prazeniu suchej masy (z obliczen)\nMetoda wagowa PN-EN 15935:2022-01","categories":["water"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Loss on ignition of dry matter","parameters_en":[{"name":"Range","range":"(7,0 – 85,0)%"},{"name":"Pozostałość po prażeniu suchej masy (z obliczeń)"}],"search_en":"Sewage sludge Loss on ignition of dry matter Gravimetric method Range PN-EN 15935:2022-01","technique_en":"Gravimetric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(7,0 – 85,0)%"},{"name":"Pozostałość po prażeniu suchej masy (z obliczeń)"}],"search_zh":"污泥 干物质烧失量 重量法 范围 PN-EN 15935:2022-01","technique_zh":"重量法","test_object_zh":"污泥","methodology_zh":"干物质烧失量"},{"_id":"6a836fb9af14b9c0e7b1eb2f","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiał budowlany: gips","methodology":"Zawartość wilgoci","parameters":[{"name":"Zakres","range":"(5,0 – 13,0) %"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Zawartość wilgoci\nZakres (5,0 – 13,0) %\nMetoda grawimetryczna","reference":"VGB-M 701 e:2008 p. 1.2","norm_bases":["VGB-M 701 e:2008 p. 1.2"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiał budowlany: gips Zawartość wilgoci\nZakres (5,0 – 13,0) %\nMetoda grawimetryczna VGB-M 701 e:2008 p. 1.2 Material budowlany: gips Zawartosc wilgoci\nZakres (5,0 – 13,0) %\nMetoda grawimetryczna VGB-M 701 e:2008 p. 1.2","categories":["materials","construction"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Moisture content","parameters_en":[{"name":"Range","range":"(5,0 – 13,0) %"}],"search_en":"Construction material: gypsum Moisture content Gravimetric method Range VGB-M 701 e:2008 p. 1.2","technique_en":"Gravimetric method","test_object_en":"Construction material: gypsum","parameters_zh":[{"name":"范围","range":"(5,0 – 13,0) %"}],"search_zh":"建筑材料：石膏 水分含量 重量法 范围 VGB-M 701 e:2008 p. 1.2","technique_zh":"重量法","methodology_zh":"水分含量","test_object_zh":"建筑材料：石膏"},{"_id":"6a836fb9af14b9c0e7b1eb30","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiał budowlany: gips","methodology":"Stopień czystości (CaSO4x2H2O)","parameters":[{"name":"Zakres","range":"(96,0 – 99,0) %"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stopień czystości (CaSO4x2H2O)\nZakres (96,0 – 99,0) %\nMetoda grawimetryczna","reference":"VGB-M 701 e:2008 p. 2.1","norm_bases":["VGB-M 701 e:2008 p. 2.1"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiał budowlany: gips Stopień czystości (CaSO4x2H2O)\nZakres (96,0 – 99,0) %\nMetoda grawimetryczna VGB-M 701 e:2008 p. 2.1 Material budowlany: gips Stopien czystosci (CaSO4x2H2O)\nZakres (96,0 – 99,0) %\nMetoda grawimetryczna VGB-M 701 e:2008 p. 2.1","categories":["materials","construction"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Purity (CaSO4x2H2O)","parameters_en":[{"name":"Range","range":"(96,0 – 99,0) %"}],"search_en":"Construction material: gypsum Purity (CaSO4x2H2O) Gravimetric method Range VGB-M 701 e:2008 p. 2.1","technique_en":"Gravimetric method","test_object_en":"Construction material: gypsum","parameters_zh":[{"name":"范围","range":"(96,0 – 99,0) %"}],"search_zh":"建筑材料：石膏 重量法 范围 VGB-M 701 e:2008 p. 2.1","technique_zh":"重量法","test_object_zh":"建筑材料：石膏"},{"_id":"6a836fb9af14b9c0e7b1eb31","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiał budowlany: gips","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 – 9,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 – 9,0\nMetoda potencjometryczna","reference":"VGB-M 701 e:2008 p. 4","norm_bases":["VGB-M 701 e:2008 p. 4"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiał budowlany: gips pH\nZakres 4,0 – 9,0\nMetoda potencjometryczna VGB-M 701 e:2008 p. 4 Material budowlany: gips pH\nZakres 4,0 – 9,0\nMetoda potencjometryczna VGB-M 701 e:2008 p. 4","categories":["materials","construction"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 – 9,0"}],"search_en":"Construction material: gypsum pH Potentiometric method Range VGB-M 701 e:2008 p. 4","technique_en":"Potentiometric method","test_object_en":"Construction material: gypsum","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 9,0"}],"search_zh":"建筑材料：石膏 pH 值 电位法 范围 VGB-M 701 e:2008 p. 4","technique_zh":"电位法","test_object_zh":"建筑材料：石膏"},{"_id":"6a836fb9af14b9c0e7b1eb32","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiał budowlany: gips","methodology":"Stopień białości","parameters":[{"name":"Zakres","range":"(35,0 – 78,0) % Ry"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stopień białości\nZakres (35,0 – 78,0) % Ry\nMetoda spektrofotometryczna","reference":"VGB-M 701 e:2008 p. 5","norm_bases":["VGB-M 701 e:2008 p. 5"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiał budowlany: gips Stopień białości\nZakres (35,0 – 78,0) % Ry\nMetoda spektrofotometryczna VGB-M 701 e:2008 p. 5 Material budowlany: gips Stopien bialosci\nZakres (35,0 – 78,0) % Ry\nMetoda spektrofotometryczna VGB-M 701 e:2008 p. 5","categories":["materials","construction"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Degree of whiteness","parameters_en":[{"name":"Range","range":"(35,0 – 78,0) % Ry"}],"search_en":"Construction material: gypsum Degree of whiteness Spectrophotometric method Range VGB-M 701 e:2008 p. 5","technique_en":"Spectrophotometric method","test_object_en":"Construction material: gypsum","parameters_zh":[{"name":"范围","range":"(35,0 – 78,0) % Ry"}],"search_zh":"建筑材料：石膏 白度 分光光度法 范围 VGB-M 701 e:2008 p. 5","technique_zh":"分光光度法","test_object_zh":"建筑材料：石膏","methodology_zh":"白度"},{"_id":"6a836fb9af14b9c0e7b1eb33","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiał budowlany: gips","methodology":"Rozmiar cząstek – analiza granulometryczna >32 μm","parameters":[{"name":"Zakres","range":"(48,0 – 86,0) %"}],"technique":"Metoda dyfrakcji laserowej","techniques":["Metoda dyfrakcji laserowej"],"computed":[],"activity":"Rozmiar cząstek – analiza granulometryczna >32 μm\nZakres (48,0 – 86,0) %\nMetoda dyfrakcji laserowej","reference":"Metoda nr 184 wydanie 2 z dnia 13.12.2023","norm_bases":["Metoda nr 184 wydanie 2 z dnia 13.12.2023"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiał budowlany: gips Rozmiar cząstek – analiza granulometryczna >32 μm\nZakres (48,0 – 86,0) %\nMetoda dyfrakcji laserowej Metoda nr 184 wydanie 2 z dnia 13.12.2023 Material budowlany: gips Rozmiar czastek – analiza granulometryczna >32 μm\nZakres (48,0 – 86,0) %\nMetoda dyfrakcji laserowej Metoda nr 184 wydanie 2 z dnia 13.12.2023","categories":["materials","construction"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Particle size – granulometric analysis >32 μm","parameters_en":[{"name":"Range","range":"(48,0 – 86,0) %"}],"search_en":"Construction material: gypsum Particle size – granulometric analysis >32 μm Laser diffraction method Range Metoda nr 184 wydanie 2 z dnia 13.12.2023","technique_en":"Laser diffraction method","test_object_en":"Construction material: gypsum","parameters_zh":[{"name":"范围","range":"(48,0 – 86,0) %"}],"search_zh":"建筑材料：石膏 激光衍射法 范围 Metoda nr 184 wydanie 2 z dnia 13.12.2023","technique_zh":"激光衍射法","test_object_zh":"建筑材料：石膏"},{"_id":"6a836fb9af14b9c0e7b1eb34","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiał budowlany: gips","methodology":"Oznaczanie węglanów jako CaCO3","parameters":[{"name":"Zakres","range":"(0,15 – 1,15) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Oznaczanie węglanów jako CaCO3\nZakres (0,15 – 1,15) %\nMetoda miareczkowa","reference":"VGB-M 701 e:2008 p. 8.12","norm_bases":["VGB-M 701 e:2008 p. 8.12"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiał budowlany: gips Oznaczanie węglanów jako CaCO3\nZakres (0,15 – 1,15) %\nMetoda miareczkowa VGB-M 701 e:2008 p. 8.12 Material budowlany: gips Oznaczanie weglanow jako CaCO3\nZakres (0,15 – 1,15) %\nMetoda miareczkowa VGB-M 701 e:2008 p. 8.12","categories":["materials","construction"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Determination of carbonates as CaCO3","parameters_en":[{"name":"Range","range":"(0,15 – 1,15) %"}],"search_en":"Construction material: gypsum Determination of carbonates as CaCO3 Titrimetric method Range VGB-M 701 e:2008 p. 8.12","technique_en":"Titrimetric method","test_object_en":"Construction material: gypsum","parameters_zh":[{"name":"范围","range":"(0,15 – 1,15) %"}],"search_zh":"建筑材料：石膏 滴定法 范围 VGB-M 701 e:2008 p. 8.12","technique_zh":"滴定法","test_object_zh":"建筑材料：石膏"},{"_id":"6a836fb9af14b9c0e7b1eb35","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiał budowlany: gips","methodology":"Zawartość chlorków Cl-","parameters":[{"name":"Zakres","range":"(24 – 130) mg/kg"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość chlorków Cl-\nZakres (24 – 130) mg/kg\nMetoda miareczkowa","reference":"VGB-M 701 e:2008 p. 8.8.3","norm_bases":["VGB-M 701 e:2008 p. 8.8.3"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiał budowlany: gips Zawartość chlorków Cl-\nZakres (24 – 130) mg/kg\nMetoda miareczkowa VGB-M 701 e:2008 p. 8.8.3 Material budowlany: gips Zawartosc chlorkow Cl-\nZakres (24 – 130) mg/kg\nMetoda miareczkowa VGB-M 701 e:2008 p. 8.8.3","categories":["materials","construction"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride content Cl-","parameters_en":[{"name":"Range","range":"(24 – 130) mg/kg"}],"search_en":"Construction material: gypsum Chloride content Cl- Titrimetric method Range VGB-M 701 e:2008 p. 8.8.3","technique_en":"Titrimetric method","test_object_en":"Construction material: gypsum","parameters_zh":[{"name":"范围","range":"(24 – 130) mg/kg"}],"search_zh":"建筑材料：石膏 滴定法 范围 VGB-M 701 e:2008 p. 8.8.3","technique_zh":"滴定法","test_object_zh":"建筑材料：石膏"},{"_id":"6a836fb9af14b9c0e7b1eb36","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: gaz ziemny, gaz suchy, gazy wodorowe, gazy wysokociśnieniowe, gazy niskociśnieniowe","methodology":"Zawartość siarkowodoru","parameters":[{"name":"Zakres","range":"(0,0002 – 0,0650) %(v/v)"},{"name":"Zakres","range":"(0,0650 – 93) %(v/v)"}],"technique":"Metoda miareczkowa; Metoda miareczkowa","techniques":["Metoda miareczkowa","Metoda miareczkowa"],"computed":[],"activity":"Zawartość siarkowodoru\nZakres:\nZakres (0,0002 – 0,0650) %(v/v)\nZakres (0,0650 – 93) %(v/v)\nMetoda miareczkowa; Metoda miareczkowa","reference":"Metoda 041 wydanie 6 z dnia 14.11.2024","norm_bases":["Metoda 041 wydanie 6 z dnia 14.11.2024"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: gaz ziemny, gaz suchy, gazy wodorowe, gazy wysokociśnieniowe, gazy niskociśnieniowe Zawartość siarkowodoru\nZakres:\nZakres (0,0002 – 0,0650) %(v/v)\nZakres (0,0650 – 93) %(v/v)\nMetoda miareczkowa; Metoda miareczkowa Metoda 041 wydanie 6 z dnia 14.11.2024 Paliwa gazowe: gaz ziemny, gaz suchy, gazy wodorowe, gazy wysokocisnieniowe, gazy niskocisnieniowe Zawartosc siarkowodoru\nZakres:\nZakres (0,0002 – 0,0650) %(v/v)\nZakres (0,0650 – 93) %(v/v)\nMetoda miareczkowa; Metoda miareczkowa Metoda 041 wydanie 6 z dnia 14.11.2024","categories":["petro"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrogen sulphide content","parameters_en":[{"name":"Range","range":"(0,0002 – 0,0650) %(v/v)"},{"name":"Range","range":"(0,0650 – 93) %(v/v)"}],"search_en":"Gaseous fuels: natural gas, dry gas, hydrogen gases, high-pressure gases, low-pressure gases Hydrogen sulphide content Titrimetric method; Titrimetric method Range Range Metoda 041 wydanie 6 z dnia 14.11.2024","technique_en":"Titrimetric method; Titrimetric method","test_object_en":"Gaseous fuels: natural gas, dry gas, hydrogen gases, high-pressure gases, low-pressure gases","parameters_zh":[{"name":"范围","range":"(0,0002 – 0,0650) %(v/v)"},{"name":"范围","range":"(0,0650 – 93) %(v/v)"}],"search_zh":"硫化氢含量 滴定法；滴定法 范围 范围 Metoda 041 wydanie 6 z dnia 14.11.2024","methodology_zh":"硫化氢含量","technique_zh":"滴定法；滴定法"},{"_id":"6a836fb9af14b9c0e7b1eb37","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Liczba jodowa","parameters":[{"name":"Zakres","range":"(105 – 120) g jodu/100g FAME"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Liczba jodowa\nZakres (105 – 120) g jodu/100g FAME\nMetoda miareczkowa","reference":"PN-EN 14111:2022-11","norm_bases":["PN-EN 14111:2022-11"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Liczba jodowa\nZakres (105 – 120) g jodu/100g FAME\nMetoda miareczkowa PN-EN 14111:2022-11 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Liczba jodowa\nZakres (105 – 120) g jodu/100g FAME\nMetoda miareczkowa PN-EN 14111:2022-11","categories":["petro"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Iodine value","parameters_en":[{"name":"Range","range":"(105 – 120) g jodu/100g FAME"}],"search_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME) Iodine value Titrimetric method Range PN-EN 14111:2022-11","technique_en":"Titrimetric method","test_object_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME)","parameters_zh":[{"name":"范围","range":"(105 – 120) g jodu/100g FAME"}],"search_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME） 碘值 滴定法 范围 PN-EN 14111:2022-11","technique_zh":"滴定法","test_object_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME）","methodology_zh":"碘值"},{"_id":"6a836fb9af14b9c0e7b1eb38","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: olej napędowy z FAME, estry metylowe kwasów tłuszczowych (FAME)","methodology":"Liczba kwasowa","parameters":[{"name":"Zakres","range":"(0,10 – 1,00) mg KOH/g"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Liczba kwasowa\nZakres (0,10 – 1,00) mg KOH/g\nMetoda miareczkowa","reference":"PN-EN 14104:2021-06","norm_bases":["PN-EN 14104:2021-06"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: olej napędowy z FAME, estry metylowe kwasów tłuszczowych (FAME) Liczba kwasowa\nZakres (0,10 – 1,00) mg KOH/g\nMetoda miareczkowa PN-EN 14104:2021-06 Paliwa ciekle: biopaliwa ciekle: olej napedowy z FAME, estry metylowe kwasow tluszczowych (FAME) Liczba kwasowa\nZakres (0,10 – 1,00) mg KOH/g\nMetoda miareczkowa PN-EN 14104:2021-06","categories":["petro"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Acid value","parameters_en":[{"name":"Range","range":"(0,10 – 1,00) mg KOH/g"}],"search_en":"Liquid fuels: liquid biofuels: diesel fuel with FAME, fatty acid methyl esters (FAME) Acid value Titrimetric method Range PN-EN 14104:2021-06","technique_en":"Titrimetric method","test_object_en":"Liquid fuels: liquid biofuels: diesel fuel with FAME, fatty acid methyl esters (FAME)","parameters_zh":[{"name":"范围","range":"(0,10 – 1,00) mg KOH/g"}],"search_zh":"酸值 滴定法 范围 PN-EN 14104:2021-06","technique_zh":"滴定法","methodology_zh":"酸值"},{"_id":"6a836fb9af14b9c0e7b1eb39","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: bioetanol","methodology":"Sucha pozostałość","parameters":[{"name":"Zakres","range":"(5 – 25) mg/100ml"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha pozostałość\nZakres (5 – 25) mg/100ml\nMetoda wagowa","reference":"PN-EN 15691:2023-11","norm_bases":["PN-EN 15691:2023-11"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: bioetanol Sucha pozostałość\nZakres (5 – 25) mg/100ml\nMetoda wagowa PN-EN 15691:2023-11 Paliwa ciekle: biopaliwa ciekle: bioetanol Sucha pozostalosc\nZakres (5 – 25) mg/100ml\nMetoda wagowa PN-EN 15691:2023-11","categories":["petro"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry residue","parameters_en":[{"name":"Range","range":"(5 – 25) mg/100ml"}],"search_en":"Liquid fuels: liquid biofuels: bioethanol Dry residue Gravimetric method Range PN-EN 15691:2023-11","technique_en":"Gravimetric method","test_object_en":"Liquid fuels: liquid biofuels: bioethanol","parameters_zh":[{"name":"范围","range":"(5 – 25) mg/100ml"}],"search_zh":"液体燃料：液体生物燃料：生物乙醇 干残渣 重量法 范围 PN-EN 15691:2023-11","technique_zh":"重量法","methodology_zh":"干残渣","test_object_zh":"液体燃料：液体生物燃料：生物乙醇"},{"_id":"6a836fb9af14b9c0e7b1eb3a","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: bioetanol","methodology":"Całkowita kwasowość","parameters":[{"name":"Zakres","range":"(0,003 – 0,013) %(m/m)"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Całkowita kwasowość\nZakres (0,003 – 0,013) %(m/m)\nMetoda miareczkowa","reference":"PN-EN 15491:2025-08","norm_bases":["PN-EN 15491:2025-08"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: bioetanol Całkowita kwasowość\nZakres (0,003 – 0,013) %(m/m)\nMetoda miareczkowa PN-EN 15491:2025-08 Paliwa ciekle: biopaliwa ciekle: bioetanol Calkowita kwasowosc\nZakres (0,003 – 0,013) %(m/m)\nMetoda miareczkowa PN-EN 15491:2025-08","categories":["petro"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total acidity","parameters_en":[{"name":"Range","range":"(0,003 – 0,013) %(m/m)"}],"search_en":"Liquid fuels: liquid biofuels: bioethanol Total acidity Titrimetric method Range PN-EN 15491:2025-08","technique_en":"Titrimetric method","test_object_en":"Liquid fuels: liquid biofuels: bioethanol","parameters_zh":[{"name":"范围","range":"(0,003 – 0,013) %(m/m)"}],"search_zh":"液体燃料：液体生物燃料：生物乙醇 滴定法 范围 PN-EN 15491:2025-08","technique_zh":"滴定法","test_object_zh":"液体燃料：液体生物燃料：生物乙醇"},{"_id":"6a836fb9af14b9c0e7b1eb3b","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: bioetanol","methodology":"Zawartość wody","parameters":[{"name":"Zakres","range":"(0,073 – 0,500) %(m/m)"}],"technique":"Metoda miareczkowania kulometrycznego","techniques":["Metoda miareczkowania kulometrycznego"],"computed":[],"activity":"Zawartość wody\nZakres (0,073 – 0,500) %(m/m)\nMetoda miareczkowania kulometrycznego","reference":"PN-EN 15489:2009","norm_bases":["PN-EN 15489:2009"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: bioetanol Zawartość wody\nZakres (0,073 – 0,500) %(m/m)\nMetoda miareczkowania kulometrycznego PN-EN 15489:2009 Paliwa ciekle: biopaliwa ciekle: bioetanol Zawartosc wody\nZakres (0,073 – 0,500) %(m/m)\nMetoda miareczkowania kulometrycznego PN-EN 15489:2009","categories":["petro","water"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water content","parameters_en":[{"name":"Range","range":"(0,073 – 0,500) %(m/m)"}],"search_en":"Liquid fuels: liquid biofuels: bioethanol Water content Coulometric titration method Range PN-EN 15489:2009","technique_en":"Coulometric titration method","test_object_en":"Liquid fuels: liquid biofuels: bioethanol","methodology_zh":"水分含量","parameters_zh":[{"name":"范围","range":"(0,073 – 0,500) %(m/m)"}],"search_zh":"液体燃料：液体生物燃料：生物乙醇 水分含量 库仑滴定法 范围 PN-EN 15489:2009","technique_zh":"库仑滴定法","test_object_zh":"液体燃料：液体生物燃料：生物乙醇"},{"_id":"6a836fb9af14b9c0e7b1eb3c","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: bioetanol","methodology":"Zawartość fosforu","parameters":[{"name":"Zakres","range":"(0,15 – 1,5) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość fosforu\nZakres (0,15 – 1,5) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 15487:2009","norm_bases":["PN-EN 15487:2009"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: bioetanol Zawartość fosforu\nZakres (0,15 – 1,5) mg/l\nMetoda spektrofotometryczna PN-EN 15487:2009 Paliwa ciekle: biopaliwa ciekle: bioetanol Zawartosc fosforu\nZakres (0,15 – 1,5) mg/l\nMetoda spektrofotometryczna PN-EN 15487:2009","categories":["petro"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phosphorus content","parameters_en":[{"name":"Range","range":"(0,15 – 1,5) mg/l"}],"search_en":"Liquid fuels: liquid biofuels: bioethanol Phosphorus content Spectrophotometric method Range PN-EN 15487:2009","technique_en":"Spectrophotometric method","test_object_en":"Liquid fuels: liquid biofuels: bioethanol","parameters_zh":[{"name":"范围","range":"(0,15 – 1,5) mg/l"}],"search_zh":"液体燃料：液体生物燃料：生物乙醇 磷含量 分光光度法 范围 PN-EN 15487:2009","technique_zh":"分光光度法","methodology_zh":"磷含量","test_object_zh":"液体燃料：液体生物燃料：生物乙醇"},{"_id":"6a836fb9af14b9c0e7b1eb3d","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: bioetanol","methodology":"Zawartość chlorków nieorganicznych","parameters":[{"name":"Zakres","range":"(1,0 – 20,0) mg/kg"}],"technique":"Metoda chromatografii jonowej z detektorem konduktometrycznym (IC-CD)","techniques":["Metoda chromatografii jonowej z detektorem konduktometrycznym (IC-CD)"],"computed":[],"activity":"Zawartość chlorków nieorganicznych\nZakres (1,0 – 20,0) mg/kg\nMetoda chromatografii jonowej z detektorem konduktometrycznym (IC-CD)","reference":"PN-EN 15492:2012","norm_bases":["PN-EN 15492:2012"],"lab_section":"Pracownia Wód, Ścieków i Produktów Petrochemicznych PP4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: bioetanol Zawartość chlorków nieorganicznych\nZakres (1,0 – 20,0) mg/kg\nMetoda chromatografii jonowej z detektorem konduktometrycznym (IC-CD) PN-EN 15492:2012 Paliwa ciekle: biopaliwa ciekle: bioetanol Zawartosc chlorkow nieorganicznych\nZakres (1,0 – 20,0) mg/kg\nMetoda chromatografii jonowej z detektorem konduktometrycznym (IC-CD) PN-EN 15492:2012","categories":["petro"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Inorganic chloride content","parameters_en":[{"name":"Range","range":"(1,0 – 20,0) mg/kg"}],"search_en":"Liquid fuels: liquid biofuels: bioethanol Inorganic chloride content Ion chromatography with a conductometric detector (IC-CD) Range PN-EN 15492:2012","technique_en":"Ion chromatography with a conductometric detector (IC-CD)","test_object_en":"Liquid fuels: liquid biofuels: bioethanol","parameters_zh":[{"name":"范围","range":"(1,0 – 20,0) mg/kg"}],"search_zh":"液体燃料：液体生物燃料：生物乙醇 范围 PN-EN 15492:2012","test_object_zh":"液体燃料：液体生物燃料：生物乙醇"},{"_id":"6a836fb9af14b9c0e7b1eb3e","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa, Inne przetwory naftowe: destylaty naftowe","methodology":"Prężność par nasyconych powietrzem","parameters":[{"name":"Zakres","range":"(15,5 – 106,0) kPa"}],"technique":"Metoda mini Reid","techniques":["Metoda mini Reid"],"computed":[],"activity":"Prężność par nasyconych powietrzem\nZakres (15,5 – 106,0) kPa\nMetoda mini Reid","reference":"PN-EN 13016-1:2024-11","norm_bases":["PN-EN 13016-1:2024-11"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa, Inne przetwory naftowe: destylaty naftowe Prężność par nasyconych powietrzem\nZakres (15,5 – 106,0) kPa\nMetoda mini Reid PN-EN 13016-1:2024-11 Paliwa ciekle: benzyna bezolowiowa, Inne przetwory naftowe: destylaty naftowe Preznosc par nasyconych powietrzem\nZakres (15,5 – 106,0) kPa\nMetoda mini Reid PN-EN 13016-1:2024-11","categories":["petro","environment"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air saturated vapour pressure","parameters_en":[{"name":"Range","range":"(15,5 – 106,0) kPa"}],"search_en":"Liquid fuels: unleaded petrol, Other petroleum products: petroleum distillates Air saturated vapour pressure Mini Reid method Range PN-EN 13016-1:2024-11","technique_en":"Mini Reid method","test_object_en":"Liquid fuels: unleaded petrol, Other petroleum products: petroleum distillates","parameters_zh":[{"name":"范围","range":"(15,5 – 106,0) kPa"}],"search_zh":"空气饱和蒸气压 迷你雷德法 范围 PN-EN 13016-1:2024-11","technique_zh":"迷你雷德法","methodology_zh":"空气饱和蒸气压"},{"_id":"6a836fb9af14b9c0e7b1eb3f","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa, Inne przetwory naftowe: destylaty naftowe","methodology":"Skład frakcyjny","parameters":[{"name":"Zakres","range":"(30,0 – 360,0) 0C"}],"technique":"Metoda destylacyjna","techniques":["Metoda destylacyjna"],"computed":[],"activity":"Skład frakcyjny\nZakres (30,0 – 360,0) 0C\nMetoda destylacyjna","reference":"PN-EN ISO 3405:2019-05 z wyłączeniem pkt. 9","norm_bases":["PN-EN ISO 3405:2019-05 z wyłączeniem pkt. 9"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa, Inne przetwory naftowe: destylaty naftowe Skład frakcyjny\nZakres (30,0 – 360,0) 0C\nMetoda destylacyjna PN-EN ISO 3405:2019-05 z wyłączeniem pkt. 9 Paliwa ciekle: benzyna bezolowiowa, Inne przetwory naftowe: destylaty naftowe Sklad frakcyjny\nZakres (30,0 – 360,0) 0C\nMetoda destylacyjna PN-EN ISO 3405:2019-05 z wylaczeniem pkt. 9","categories":["petro"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fractional composition","parameters_en":[{"name":"Range","range":"(30,0 – 360,0) 0C"}],"search_en":"Liquid fuels: unleaded petrol, Other petroleum products: petroleum distillates Fractional composition Distillation method Range PN-EN ISO 3405:2019-05 z wyłączeniem pkt. 9","technique_en":"Distillation method","test_object_en":"Liquid fuels: unleaded petrol, Other petroleum products: petroleum distillates","parameters_zh":[{"name":"范围","range":"(30,0 – 360,0) 0C"}],"search_zh":"馏程组成 蒸馏法 范围 PN-EN ISO 3405:2019-05 z wyłączeniem pkt. 9","technique_zh":"蒸馏法","methodology_zh":"馏程组成"},{"_id":"6a836fb9af14b9c0e7b1eb40","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa, benzyna lotnicza","methodology":"Zawartość ołowiu","parameters":[{"name":"Zakres","range":"(2,5 – 6,0) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Zawartość ołowiu\nZakres (2,5 – 6,0) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-EN 237:2007","norm_bases":["PN-EN 237:2007"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa, benzyna lotnicza Zawartość ołowiu\nZakres (2,5 – 6,0) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN 237:2007 Paliwa ciekle: benzyna bezolowiowa, benzyna lotnicza Zawartosc olowiu\nZakres (2,5 – 6,0) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN 237:2007","categories":["petro"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Lead content","parameters_en":[{"name":"Range","range":"(2,5 – 6,0) mg/l"}],"search_en":"Liquid fuels: unleaded petrol, aviation gasoline Lead content Flame atomic absorption spectrometry (FAAS) Range PN-EN 237:2007","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Liquid fuels: unleaded petrol, aviation gasoline","parameters_zh":[{"name":"范围","range":"(2,5 – 6,0) mg/l"}],"search_zh":"铅含量 火焰原子吸收光谱法（FAAS） 范围 PN-EN 237:2007","technique_zh":"火焰原子吸收光谱法（FAAS）","methodology_zh":"铅含量"},{"_id":"6a836fb9af14b9c0e7b1eb41","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa, Inne przetwory naftowe: frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30°C - 250°C","methodology":"Liczba oktanowa LOB","parameters":[{"name":"Zakres","range":"(70 – 115)"}],"technique":"Metoda silnikowa","techniques":["Metoda silnikowa"],"computed":[],"activity":"Liczba oktanowa LOB\nZakres (70 – 115)\nMetoda silnikowa","reference":"PN-EN ISO 5164 :2014-08","norm_bases":["PN-EN ISO 5164 :2014-08"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa, Inne przetwory naftowe: frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30°C - 250°C Liczba oktanowa LOB\nZakres (70 – 115)\nMetoda silnikowa PN-EN ISO 5164 :2014-08 Paliwa ciekle: benzyna bezolowiowa, Inne przetwory naftowe: frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30°C - 250°C Liczba oktanowa LOB\nZakres (70 – 115)\nMetoda silnikowa PN-EN ISO 5164 :2014-08","categories":["petro"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Octane number LOB","parameters_en":[{"name":"Range","range":"(70 – 115)"}],"search_en":"Liquid fuels: unleaded petrol, Other petroleum products: petroleum fractions and/or products with a boiling range of 30°C - 250°C Octane number LOB Motor method Range PN-EN ISO 5164 :2014-08","technique_en":"Motor method","test_object_en":"Liquid fuels: unleaded petrol, Other petroleum products: petroleum fractions and/or products with a boiling range of 30°C - 250°C","parameters_zh":[{"name":"范围","range":"(70 – 115)"}],"search_zh":"发动机法 范围 PN-EN ISO 5164 :2014-08","technique_zh":"发动机法"},{"_id":"6a836fb9af14b9c0e7b1eb42","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa, Inne przetwory naftowe: frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30°C - 250°C","methodology":"Liczba oktanowa LOM","parameters":[{"name":"Zakres","range":"(70 – 107)"}],"technique":"Metoda silnikowa","techniques":["Metoda silnikowa"],"computed":[],"activity":"Liczba oktanowa LOM\nZakres (70 – 107)\nMetoda silnikowa","reference":"PN-EN ISO 5163 :2014-08","norm_bases":["PN-EN ISO 5163 :2014-08"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa, Inne przetwory naftowe: frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30°C - 250°C Liczba oktanowa LOM\nZakres (70 – 107)\nMetoda silnikowa PN-EN ISO 5163 :2014-08 Paliwa ciekle: benzyna bezolowiowa, Inne przetwory naftowe: frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30°C - 250°C Liczba oktanowa LOM\nZakres (70 – 107)\nMetoda silnikowa PN-EN ISO 5163 :2014-08","categories":["petro"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Motor octane number MON","parameters_en":[{"name":"Range","range":"(70 – 107)"}],"search_en":"Liquid fuels: unleaded petrol, Other petroleum products: petroleum fractions and/or products with a boiling range of 30°C - 250°C Motor octane number MON Motor method Range PN-EN ISO 5163 :2014-08","technique_en":"Motor method","test_object_en":"Liquid fuels: unleaded petrol, Other petroleum products: petroleum fractions and/or products with a boiling range of 30°C - 250°C","parameters_zh":[{"name":"范围","range":"(70 – 107)"}],"search_zh":"马达法辛烷值 MON 发动机法 范围 PN-EN ISO 5163 :2014-08","technique_zh":"发动机法","methodology_zh":"马达法辛烷值 MON"},{"_id":"6a836fb9af14b9c0e7b1eb43","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa, Inne przetwory naftowe: frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30°C - 250°C","methodology":"Stabilność oksydacyjna","parameters":[{"name":"Zakres","range":"(60 – 700) minut"}],"technique":"Metoda okresu indukcyjnego","techniques":["Metoda okresu indukcyjnego"],"computed":[],"activity":"Stabilność oksydacyjna\nZakres (60 – 700) minut\nMetoda okresu indukcyjnego","reference":"PN-EN ISO 7536:2011","norm_bases":["PN-EN ISO 7536:2011"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa, Inne przetwory naftowe: frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30°C - 250°C Stabilność oksydacyjna\nZakres (60 – 700) minut\nMetoda okresu indukcyjnego PN-EN ISO 7536:2011 Paliwa ciekle: benzyna bezolowiowa, Inne przetwory naftowe: frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30°C - 250°C Stabilnosc oksydacyjna\nZakres (60 – 700) minut\nMetoda okresu indukcyjnego PN-EN ISO 7536:2011","categories":["petro"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Oxidation stability","parameters_en":[{"name":"Range","range":"(60 – 700) minut"}],"search_en":"Liquid fuels: unleaded petrol, Other petroleum products: petroleum fractions and/or products with a boiling range of 30°C - 250°C Oxidation stability Induction period method Range PN-EN ISO 7536:2011","technique_en":"Induction period method","test_object_en":"Liquid fuels: unleaded petrol, Other petroleum products: petroleum fractions and/or products with a boiling range of 30°C - 250°C","parameters_zh":[{"name":"范围","range":"(60 – 700) minut"}],"search_zh":"氧化安定性 诱导期法 范围 PN-EN ISO 7536:2011","methodology_zh":"氧化安定性","technique_zh":"诱导期法"},{"_id":"6a836fb9af14b9c0e7b1eb44","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Zawartość manganu","parameters":[{"name":"Zakres","range":"(2,0 – 4,0) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Zawartość manganu\nZakres (2,0 – 4,0) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-EN 16135 :2012","norm_bases":["PN-EN 16135 :2012"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Zawartość manganu\nZakres (2,0 – 4,0) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN 16135 :2012 Paliwa ciekle: benzyna bezolowiowa Zawartosc manganu\nZakres (2,0 – 4,0) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN 16135 :2012","categories":["petro"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Manganese content","parameters_en":[{"name":"Range","range":"(2,0 – 4,0) mg/l"}],"search_en":"Liquid fuels: unleaded petrol Manganese content Flame atomic absorption spectrometry (FAAS) Range PN-EN 16135 :2012","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Liquid fuels: unleaded petrol","parameters_zh":[{"name":"范围","range":"(2,0 – 4,0) mg/l"}],"search_zh":"液体燃料：无铅汽油 锰含量 火焰原子吸收光谱法（FAAS） 范围 PN-EN 16135 :2012","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"液体燃料：无铅汽油","methodology_zh":"锰含量"},{"_id":"6a836fb9af14b9c0e7b1eb45","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Indeks lotności (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Indeks lotności (z obliczeń)","reference":"PN-EN 228+A1:2017-06 p. 5.5.2","norm_bases":["PN-EN 228+A1:2017-06 p. 5.5.2"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Indeks lotności (z obliczeń) PN-EN 228+A1:2017-06 p. 5.5.2 Paliwa ciekle: benzyna bezolowiowa Indeks lotnosci (z obliczen) PN-EN 228+A1:2017-06 p. 5.5.2","categories":["petro"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Volatility index (calculated)","search_en":"Liquid fuels: unleaded petrol Volatility index (calculated) PN-EN 228+A1:2017-06 p. 5.5.2","test_object_en":"Liquid fuels: unleaded petrol","search_zh":"液体燃料：无铅汽油 挥发性指数（计算值） PN-EN 228+A1:2017-06 p. 5.5.2","test_object_zh":"液体燃料：无铅汽油","methodology_zh":"挥发性指数（计算值）"},{"_id":"6a836fb9af14b9c0e7b1eb46","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Zawartość benzenu","parameters":[{"name":"Zakres","range":"(0,1 – 1,0) %(v/v)"}],"technique":"Metoda spektrometrii w zakresie podczerwieni IR","techniques":["Metoda spektrometrii w zakresie podczerwieni IR"],"computed":[],"activity":"Zawartość benzenu\nZakres (0,1 – 1,0) %(v/v)\nMetoda spektrometrii w zakresie podczerwieni IR","reference":"PN-EN 238:2000+A1:2008","norm_bases":["PN-EN 238:2000+A1:2008"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Zawartość benzenu\nZakres (0,1 – 1,0) %(v/v)\nMetoda spektrometrii w zakresie podczerwieni IR PN-EN 238:2000+A1:2008 Paliwa ciekle: benzyna bezolowiowa Zawartosc benzenu\nZakres (0,1 – 1,0) %(v/v)\nMetoda spektrometrii w zakresie podczerwieni IR PN-EN 238:2000+A1:2008","categories":["petro"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Benzene content","parameters_en":[{"name":"Range","range":"(0,1 – 1,0) %(v/v)"}],"search_en":"Liquid fuels: unleaded petrol Benzene content Spectrometry method in the infrared range IR Range PN-EN 238:2000+A1:2008","technique_en":"Spectrometry method in the infrared range IR","test_object_en":"Liquid fuels: unleaded petrol","parameters_zh":[{"name":"范围","range":"(0,1 – 1,0) %(v/v)"}],"search_zh":"液体燃料：无铅汽油 苯含量 红外光谱法 IR 范围 PN-EN 238:2000+A1:2008","technique_zh":"红外光谱法 IR","test_object_zh":"液体燃料：无铅汽油","methodology_zh":"苯含量"},{"_id":"6a836fb9af14b9c0e7b1eb47","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa, Inne przetwory naftowe: komponenty benzynowe","methodology":"Zawartość grup węglowodorów i związków tlenowych","parameters":[{"name":"całkowita zawartość węglowodorów"},{"name":"aromatycznych","range":"(10,0 – 50,0) %(v/v)"},{"name":"całkowita zawartość olefin:"},{"name":"Zakres","range":"(0,4 – 26,85) % (v/v)"},{"name":"zawartość benzenu","range":"(0,38 – 1,96) %(v/v)"},{"name":"zawartość związków tlenowych: ETBE","range":"(0,61 – 14,8) %(v/v)"},{"name":"MTBE","range":"(0,61 – 15,0) %(v/v)"},{"name":"ETOH","range":"(0,61 – 16,0) %(v/v)"},{"name":"Całkowita zawartość tlenu (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość grup węglowodorów i związków tlenowych\nZakres:\ncałkowita zawartość węglowodorów\naromatycznych (10,0 – 50,0) %(v/v)\ncałkowita zawartość olefin:\nZakres (0,4 – 26,85) % (v/v)\nzawartość benzenu (0,38 – 1,96) %(v/v)\nzawartość związków tlenowych: ETBE (0,61 – 14,8) %(v/v)\nMTBE (0,61 – 15,0) %(v/v)\nETOH (0,61 – 16,0) %(v/v)\nCałkowita zawartość tlenu (z obliczeń)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN ISO 22854:2025-07 Procedura A","norm_bases":["PN-EN ISO 22854:2025-07 Procedura A"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa, Inne przetwory naftowe: komponenty benzynowe Zawartość grup węglowodorów i związków tlenowych\nZakres:\ncałkowita zawartość węglowodorów\naromatycznych (10,0 – 50,0) %(v/v)\ncałkowita zawartość olefin:\nZakres (0,4 – 26,85) % (v/v)\nzawartość benzenu (0,38 – 1,96) %(v/v)\nzawartość związków tlenowych: ETBE (0,61 – 14,8) %(v/v)\nMTBE (0,61 – 15,0) %(v/v)\nETOH (0,61 – 16,0) %(v/v)\nCałkowita zawartość tlenu (z obliczeń)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN ISO 22854:2025-07 Procedura A Paliwa ciekle: benzyna bezolowiowa, Inne przetwory naftowe: komponenty benzynowe Zawartosc grup weglowodorow i zwiazkow tlenowych\nZakres:\ncalkowita zawartosc weglowodorow\naromatycznych (10,0 – 50,0) %(v/v)\ncalkowita zawartosc olefin:\nZakres (0,4 – 26,85) % (v/v)\nzawartosc benzenu (0,38 – 1,96) %(v/v)\nzawartosc zwiazkow tlenowych: ETBE (0,61 – 14,8) %(v/v)\nMTBE (0,61 – 15,0) %(v/v)\nETOH (0,61 – 16,0) %(v/v)\nCalkowita zawartosc tlenu (z obliczen)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN ISO 22854:2025-07 Procedura A","categories":["petro"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of hydrocarbon groups and oxygenates","parameters_en":[{"name":"total hydrocarbon content"},{"name":"aromatic","range":"(10,0 – 50,0) %(v/v)"},{"name":"total olefin content:"},{"name":"Range","range":"(0,4 – 26,85) % (v/v)"},{"name":"benzene content","range":"(0,38 – 1,96) %(v/v)"},{"name":"content of oxygenates: ETBE","range":"(0,61 – 14,8) %(v/v)"},{"name":"MTBE","range":"(0,61 – 15,0) %(v/v)"},{"name":"ETOH","range":"(0,61 – 16,0) %(v/v)"},{"name":"Total oxygen content (calculated)"}],"search_en":"Liquid fuels: unleaded petrol, Other petroleum products: petrol components Content of hydrocarbon groups and oxygenates Gas chromatography with flame ionization detection (GC-FID) total hydrocarbon content aromatic total olefin content: Range benzene content content of oxygenates: ETBE MTBE ETOH Total oxygen content (calculated) PN-EN ISO 22854:2025-07 Procedura A","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Liquid fuels: unleaded petrol, Other petroleum products: petrol components","parameters_zh":[{"name":"całkowita zawartość węglowodorów"},{"name":"aromatycznych","range":"(10,0 – 50,0) %(v/v)"},{"name":"całkowita zawartość olefin:"},{"name":"范围","range":"(0,4 – 26,85) % (v/v)"},{"name":"zawartość benzenu","range":"(0,38 – 1,96) %(v/v)"},{"name":"zawartość związków tlenowych: ETBE","range":"(0,61 – 14,8) %(v/v)"},{"name":"MTBE","range":"(0,61 – 15,0) %(v/v)"},{"name":"ETOH","range":"(0,61 – 16,0) %(v/v)"},{"name":"总氧含量（由计算得出）"}],"search_zh":"烃族与含氧化合物含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 总氧含量（由计算得出） PN-EN ISO 22854:2025-07 Procedura A","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","methodology_zh":"烃族与含氧化合物含量"},{"_id":"6a836fb9af14b9c0e7b1eb48","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych","methodology":"Gęstość w temperaturze 15°C","parameters":[{"name":"Zakres","range":"(700,0 – 860,0) kg/m3"}],"technique":"Metoda areometryczna","techniques":["Metoda areometryczna"],"computed":[],"activity":"Gęstość w temperaturze 15°C\nZakres (700,0 – 860,0) kg/m3\nMetoda areometryczna","reference":"ASTM D 1298-12b (2017)","norm_bases":["ASTM D 1298-12b (2017)"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych Gęstość w temperaturze 15°C\nZakres (700,0 – 860,0) kg/m3\nMetoda areometryczna ASTM D 1298-12b (2017) Paliwa ciekle: paliwo do turbinowych silnikow lotniczych Gestosc w temperaturze 15°C\nZakres (700,0 – 860,0) kg/m3\nMetoda areometryczna ASTM D 1298-12b (2017)","categories":["petro"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Density at 15°C","parameters_en":[{"name":"Range","range":"(700,0 – 860,0) kg/m3"}],"search_en":"Liquid fuels: aviation turbine fuel Density at 15°C Hydrometer method Range ASTM D 1298-12b (2017)","technique_en":"Hydrometer method","test_object_en":"Liquid fuels: aviation turbine fuel","parameters_zh":[{"name":"范围","range":"(700,0 – 860,0) kg/m3"}],"search_zh":"液体燃料：航空涡轮发动机燃料 15°C 时的密度 比重计法 范围 ASTM D 1298-12b (2017)","test_object_zh":"液体燃料：航空涡轮发动机燃料","methodology_zh":"15°C 时的密度","technique_zh":"比重计法"},{"_id":"6a836fb9af14b9c0e7b1eb49","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, benzyna lotnicza, paliwo do turbinowych silników lotniczych, Wyroby chemiczne: węglowodory aromatyczne, rozpuszczalniki, Inne przetwory naftowe: frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30oC - 300°C","methodology":"Gęstość w temperaturze 15°C i 20°C","parameters":[{"name":"Zakres","range":"(650,0 – 1100,0) kg/m3"}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"computed":[],"activity":"Gęstość w temperaturze 15°C i 20°C\nZakres (650,0 – 1100,0) kg/m3\nMetoda oscylacyjna","reference":"PN-EN ISO 12185:2024-08 | ASTM D 4052-22","norm_bases":["PN-EN ISO 12185:2024-08","ASTM D 4052-22"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, benzyna lotnicza, paliwo do turbinowych silników lotniczych, Wyroby chemiczne: węglowodory aromatyczne, rozpuszczalniki, Inne przetwory naftowe: frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30oC - 300°C Gęstość w temperaturze 15°C i 20°C\nZakres (650,0 – 1100,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08 | ASTM D 4052-22 Paliwa ciekle: olej napedowy, benzyna bezolowiowa, benzyna lotnicza, paliwo do turbinowych silnikow lotniczych, Wyroby chemiczne: weglowodory aromatyczne, rozpuszczalniki, Inne przetwory naftowe: frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30oC - 300°C Gestosc w temperaturze 15°C i 20°C\nZakres (650,0 – 1100,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08 | ASTM D 4052-22","categories":["petro"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Density at 15°C and 20°C","parameters_en":[{"name":"Range","range":"(650,0 – 1100,0) kg/m3"}],"search_en":"Liquid fuels: diesel fuel, unleaded petrol, aviation gasoline, aviation turbine fuel, Chemical products: aromatic hydrocarbons, solvents, Other petroleum products: petroleum fractions and/or products with a boiling range 30oC - 300°C Density at 15°C and 20°C Oscillation method Range PN-EN ISO 12185:2024-08 | ASTM D 4052-22","technique_en":"Oscillation method","test_object_en":"Liquid fuels: diesel fuel, unleaded petrol, aviation gasoline, aviation turbine fuel, Chemical products: aromatic hydrocarbons, solvents, Other petroleum products: petroleum fractions and/or products with a boiling range 30oC - 300°C","parameters_zh":[{"name":"范围","range":"(650,0 – 1100,0) kg/m3"}],"search_zh":"15°C 与 20°C 时的密度 振荡法 范围 PN-EN ISO 12185:2024-08 | ASTM D 4052-22","technique_zh":"振荡法","methodology_zh":"15°C 与 20°C 时的密度"},{"_id":"6a836fb9af14b9c0e7b1eb4a","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa, benzyna lotnicza, paliwo do turbinowych silników lotniczych, Inne przetwory naftowe: frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30oC - 300oC","methodology":"Zawartość żywic","parameters":[{"name":"Zakres","range":"(1 – 10) mg/100ml"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość żywic\nZakres (1 – 10) mg/100ml\nMetoda wagowa","reference":"PN-EN ISO 6246:2017-05 +A1:2020-03","norm_bases":["PN-EN ISO 6246:2017-05 +A1:2020-03"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa, benzyna lotnicza, paliwo do turbinowych silników lotniczych, Inne przetwory naftowe: frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30oC - 300oC Zawartość żywic\nZakres (1 – 10) mg/100ml\nMetoda wagowa PN-EN ISO 6246:2017-05 +A1:2020-03 Paliwa ciekle: benzyna bezolowiowa, benzyna lotnicza, paliwo do turbinowych silnikow lotniczych, Inne przetwory naftowe: frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30oC - 300oC Zawartosc zywic\nZakres (1 – 10) mg/100ml\nMetoda wagowa PN-EN ISO 6246:2017-05 +A1:2020-03","categories":["petro"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gum content","parameters_en":[{"name":"Range","range":"(1 – 10) mg/100ml"}],"search_en":"Liquid fuels: unleaded petrol, aviation gasoline, aviation turbine fuel, Other petroleum products: petroleum fractions and/or products with a boiling range 30oC - 300oC Gum content Gravimetric method Range PN-EN ISO 6246:2017-05 +A1:2020-03","technique_en":"Gravimetric method","test_object_en":"Liquid fuels: unleaded petrol, aviation gasoline, aviation turbine fuel, Other petroleum products: petroleum fractions and/or products with a boiling range 30oC - 300oC","parameters_zh":[{"name":"范围","range":"(1 – 10) mg/100ml"}],"search_zh":"树脂含量 重量法 范围 PN-EN ISO 6246:2017-05 +A1:2020-03","technique_zh":"重量法","methodology_zh":"树脂含量"},{"_id":"6a836fb9af14b9c0e7b1eb4b","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa, Inne przetwory naftowe: frakcje naftowe o zakresie temperatur wrzenia 30°C - 225°C, komponenty benzynowe","methodology":"Skład szczegółowy dla węglowodorów do n-nonanu (C9), Węglowodory niearomatyczne (0,05 – 24,00) %(m/m), Węglowodory aromatyczne (1,00 – 90,00) %(m/m)","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Skład szczegółowy dla węglowodorów do n-nonanu (C9), Węglowodory niearomatyczne (0,05 – 24,00) %(m/m), Węglowodory aromatyczne (1,00 – 90,00) %(m/m)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"ASTM D 5134-21","norm_bases":["ASTM D 5134-21"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa, Inne przetwory naftowe: frakcje naftowe o zakresie temperatur wrzenia 30°C - 225°C, komponenty benzynowe Skład szczegółowy dla węglowodorów do n-nonanu (C9), Węglowodory niearomatyczne (0,05 – 24,00) %(m/m), Węglowodory aromatyczne (1,00 – 90,00) %(m/m)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) ASTM D 5134-21 Paliwa ciekle: benzyna bezolowiowa, Inne przetwory naftowe: frakcje naftowe o zakresie temperatur wrzenia 30°C - 225°C, komponenty benzynowe Sklad szczegolowy dla weglowodorow do n-nonanu (C9), Weglowodory niearomatyczne (0,05 – 24,00) %(m/m), Weglowodory aromatyczne (1,00 – 90,00) %(m/m)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) ASTM D 5134-21","categories":["petro"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Detailed composition for hydrocarbons up to n-nonane (C9), Non-aromatic hydrocarbons (0,05 – 24,00) %(m/m), Aromatic hydrocarbons (1,00 – 90,00) %(m/m)","search_en":"Liquid fuels: unleaded petrol, Other petroleum products: petroleum fractions with a boiling range 30°C - 225°C, petrol components Detailed composition for hydrocarbons up to n-nonane (C9), Non-aromatic hydrocarbons (0,05 – 24,00) %(m/m), Aromatic hydrocarbons (1,00 – 90,00) %(m/m) Gas chromatography with flame ionization detection (GC-FID) ASTM D 5134-21","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Liquid fuels: unleaded petrol, Other petroleum products: petroleum fractions with a boiling range 30°C - 225°C, petrol components","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） ASTM D 5134-21","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a836fb9af14b9c0e7b1eb4c","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, Inne przetwory naftowe: destylaty naftowe","methodology":"Zawartość węglowodorów aromatycznych","parameters":[{"name":"jednopierścieniowe (MAH)"},{"name":"Zakres","range":"(7,0 – 30) %(m/m)"},{"name":"dwupierścieniowe (DAH)","range":"(1,0 – 9.7) %(m/m)"},{"name":"trój- i wielopierścieniowe (T+ AH)","range":"(0,1 – 2,0) %(m/m)"},{"name":"wielopierścieniowe (POLY-AH)","range":"(1,1 – 11,8) %(m/m)"},{"name":"Sumaryczna zawartość węglowodorów aromatycznych (z obliczeń)"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją refraktometryczną (HPLC-RID)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją refraktometryczną (HPLC-RID)"],"computed":[],"activity":"Zawartość węglowodorów aromatycznych\nZakres:\njednopierścieniowe (MAH)\nZakres (7,0 – 30) %(m/m)\ndwupierścieniowe (DAH) (1,0 – 9.7) %(m/m)\ntrój- i wielopierścieniowe (T+ AH) (0,1 – 2,0) %(m/m)\nwielopierścieniowe (POLY-AH) (1,1 – 11,8) %(m/m)\nSumaryczna zawartość węglowodorów aromatycznych (z obliczeń)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją refraktometryczną (HPLC-RID)","reference":"PN-EN 12916+A1:2025-07 Procedura A","norm_bases":["PN-EN 12916+A1:2025-07 Procedura A"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, Inne przetwory naftowe: destylaty naftowe Zawartość węglowodorów aromatycznych\nZakres:\njednopierścieniowe (MAH)\nZakres (7,0 – 30) %(m/m)\ndwupierścieniowe (DAH) (1,0 – 9.7) %(m/m)\ntrój- i wielopierścieniowe (T+ AH) (0,1 – 2,0) %(m/m)\nwielopierścieniowe (POLY-AH) (1,1 – 11,8) %(m/m)\nSumaryczna zawartość węglowodorów aromatycznych (z obliczeń)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją refraktometryczną (HPLC-RID) PN-EN 12916+A1:2025-07 Procedura A Paliwa ciekle: olej napedowy, Inne przetwory naftowe: destylaty naftowe Zawartosc weglowodorow aromatycznych\nZakres:\njednopierscieniowe (MAH)\nZakres (7,0 – 30) %(m/m)\ndwupierscieniowe (DAH) (1,0 – 9.7) %(m/m)\ntroj- i wielopierscieniowe (T+ AH) (0,1 – 2,0) %(m/m)\nwielopierscieniowe (POLY-AH) (1,1 – 11,8) %(m/m)\nSumaryczna zawartosc weglowodorow aromatycznych (z obliczen)\nMetoda wysokosprawnej chromatografii cieczowej z detekcja refraktometryczna (HPLC-RID) PN-EN 12916+A1:2025-07 Procedura A","categories":["petro"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Aromatic hydrocarbon content","parameters_en":[{"name":"mononuclear (MAH)"},{"name":"Range","range":"(7,0 – 30) %(m/m)"},{"name":"bicyclic (DAH)","range":"(1,0 – 9.7) %(m/m)"},{"name":"tri- and polycyclic (T+ AH)","range":"(0,1 – 2,0) %(m/m)"},{"name":"polycyclic (POLY-AH)","range":"(1,1 – 11,8) %(m/m)"},{"name":"Total content of aromatic hydrocarbons (calculated)"}],"search_en":"Liquid fuels: diesel fuel, Other petroleum products: petroleum distillates Aromatic hydrocarbon content High-performance liquid chromatography with refractive index detection (HPLC-RID) mononuclear (MAH) Range bicyclic (DAH) tri- and polycyclic (T+ AH) polycyclic (POLY-AH) Total content of aromatic hydrocarbons (calculated) PN-EN 12916+A1:2025-07 Procedura A","technique_en":"High-performance liquid chromatography with refractive index detection (HPLC-RID)","test_object_en":"Liquid fuels: diesel fuel, Other petroleum products: petroleum distillates","parameters_zh":[{"name":"jednopierścieniowe (MAH)"},{"name":"范围","range":"(7,0 – 30) %(m/m)"},{"name":"dwupierścieniowe (DAH)","range":"(1,0 – 9.7) %(m/m)"},{"name":"trój- i wielopierścieniowe (T+ AH)","range":"(0,1 – 2,0) %(m/m)"},{"name":"wielopierścieniowe (POLY-AH)","range":"(1,1 – 11,8) %(m/m)"},{"name":"芳香烃总含量（由计算得出）"}],"search_zh":"芳香烃含量 高效液相色谱-示差折光检测法（HPLC-RID） 范围 芳香烃总含量（由计算得出） PN-EN 12916+A1:2025-07 Procedura A","technique_zh":"高效液相色谱-示差折光检测法（HPLC-RID）","methodology_zh":"芳香烃含量"},{"_id":"6a836fb9af14b9c0e7b1eb4d","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Liczba cetanowa","parameters":[{"name":"Zakres","range":"50,0 – 60,0"}],"technique":"Metoda silnikowa","techniques":["Metoda silnikowa"],"computed":[],"activity":"Liczba cetanowa\nZakres 50,0 – 60,0\nMetoda silnikowa","reference":"PN-EN ISO 5165:2021-02","norm_bases":["PN-EN ISO 5165:2021-02"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Liczba cetanowa\nZakres 50,0 – 60,0\nMetoda silnikowa PN-EN ISO 5165:2021-02 Paliwa ciekle: olej napedowy, biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Liczba cetanowa\nZakres 50,0 – 60,0\nMetoda silnikowa PN-EN ISO 5165:2021-02","categories":["petro"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Cetane number","parameters_en":[{"name":"Range","range":"50,0 – 60,0"}],"search_en":"Liquid fuels: diesel fuel, liquid biofuels: fatty acid methyl esters (FAME) Cetane number Motor method Range PN-EN ISO 5165:2021-02","technique_en":"Motor method","test_object_en":"Liquid fuels: diesel fuel, liquid biofuels: fatty acid methyl esters (FAME)","parameters_zh":[{"name":"范围","range":"50,0 – 60,0"}],"search_zh":"十六烷值 发动机法 范围 PN-EN ISO 5165:2021-02","technique_zh":"发动机法","methodology_zh":"十六烷值"},{"_id":"6a836fb9af14b9c0e7b1eb4e","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki","methodology":"Zawartość estrów metylowych kwasów tłuszczowych (FAME)","parameters":[{"name":"Zakres","range":"(0,05 – 10,0) %(v/v)"}],"technique":"Metoda spektrometrii w zakresie podczerwieni IR","techniques":["Metoda spektrometrii w zakresie podczerwieni IR"],"computed":[],"activity":"Zawartość estrów metylowych kwasów tłuszczowych (FAME)\nZakres (0,05 – 10,0) %(v/v)\nMetoda spektrometrii w zakresie podczerwieni IR","reference":"PN-EN 14078:2014-06","norm_bases":["PN-EN 14078:2014-06"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki Zawartość estrów metylowych kwasów tłuszczowych (FAME)\nZakres (0,05 – 10,0) %(v/v)\nMetoda spektrometrii w zakresie podczerwieni IR PN-EN 14078:2014-06 Paliwa ciekle: olej napedowy, olej opalowy lekki Zawartosc estrow metylowych kwasow tluszczowych (FAME)\nZakres (0,05 – 10,0) %(v/v)\nMetoda spektrometrii w zakresie podczerwieni IR PN-EN 14078:2014-06","categories":["petro"],"row_index":55,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fatty acid methyl esters (FAME) content","parameters_en":[{"name":"Range","range":"(0,05 – 10,0) %(v/v)"}],"search_en":"Liquid fuels: diesel fuel, light fuel oil Fatty acid methyl esters (FAME) content Spectrometry method in the infrared range IR Range PN-EN 14078:2014-06","technique_en":"Spectrometry method in the infrared range IR","test_object_en":"Liquid fuels: diesel fuel, light fuel oil","parameters_zh":[{"name":"范围","range":"(0,05 – 10,0) %(v/v)"}],"search_zh":"液体燃料：柴油、轻质燃料油 脂肪酸甲酯（FAME）含量 红外光谱法 IR 范围 PN-EN 14078:2014-06","technique_zh":"红外光谱法 IR","test_object_zh":"液体燃料：柴油、轻质燃料油","methodology_zh":"脂肪酸甲酯（FAME）含量"},{"_id":"6a836fb9af14b9c0e7b1eb4f","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: lekki olej opałowy, mieszanki lekkiego oleju opałowego z nieoznaczonym olejem mineralnym","methodology":"Zawartość barwnika Solvent Red 19","parameters":[{"name":"Zakres","range":"(1,0 – 10,0) mg/l"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV/VIS)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV/VIS)"],"computed":[],"activity":"Zawartość barwnika Solvent Red 19\nZakres (1,0 – 10,0) mg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV/VIS)","reference":"DIN 51430:2018-02","norm_bases":["DIN 51430:2018-02"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: lekki olej opałowy, mieszanki lekkiego oleju opałowego z nieoznaczonym olejem mineralnym Zawartość barwnika Solvent Red 19\nZakres (1,0 – 10,0) mg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV/VIS) DIN 51430:2018-02 Paliwa ciekle: lekki olej opalowy, mieszanki lekkiego oleju opalowego z nieoznaczonym olejem mineralnym Zawartosc barwnika Solvent Red 19\nZakres (1,0 – 10,0) mg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC-UV/VIS) DIN 51430:2018-02","categories":["petro"],"row_index":56,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Solvent Red 19 dye content","parameters_en":[{"name":"Range","range":"(1,0 – 10,0) mg/l"}],"search_en":"Liquid fuels: light heating oil, mixtures of light heating oil with unmarked mineral oil Solvent Red 19 dye content High-performance liquid chromatography with spectrophotometric detection (HPLC-UV/VIS) Range DIN 51430:2018-02","technique_en":"High-performance liquid chromatography with spectrophotometric detection (HPLC-UV/VIS)","test_object_en":"Liquid fuels: light heating oil, mixtures of light heating oil with unmarked mineral oil","parameters_zh":[{"name":"范围","range":"(1,0 – 10,0) mg/l"}],"search_zh":"溶剂红 19 着色剂含量 高效液相色谱-分光光度检测法（HPLC-UV/VIS） 范围 DIN 51430:2018-02","technique_zh":"高效液相色谱-分光光度检测法（HPLC-UV/VIS）","methodology_zh":"溶剂红 19 着色剂含量"},{"_id":"6a836fb9af14b9c0e7b1eb50","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, benzyna lotnicza, paliwo do turbinowych silników lotniczych, Inne przetwory naftowe: komponenty benzynowe, frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30°C - 350°C","methodology":"Działanie korodujące na miedź","parameters":[{"name":"klasa korozji","range":"(1 – 4)"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Działanie korodujące na miedź\nklasa korozji (1 – 4)\nMetoda wizualna","reference":"PN-EN ISO 2160:2004","norm_bases":["PN-EN ISO 2160:2004"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, benzyna lotnicza, paliwo do turbinowych silników lotniczych, Inne przetwory naftowe: komponenty benzynowe, frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30°C - 350°C Działanie korodujące na miedź\nklasa korozji (1 – 4)\nMetoda wizualna PN-EN ISO 2160:2004 Paliwa ciekle: olej napedowy, benzyna bezolowiowa, benzyna lotnicza, paliwo do turbinowych silnikow lotniczych, Inne przetwory naftowe: komponenty benzynowe, frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30°C - 350°C Dzialanie korodujace na miedz\nklasa korozji (1 – 4)\nMetoda wizualna PN-EN ISO 2160:2004","categories":["petro","materials"],"row_index":57,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Copper strip corrosion","parameters_en":[{"name":"corrosion class","range":"(1 – 4)"}],"search_en":"Liquid fuels: diesel fuel, unleaded petrol, aviation gasoline, aviation turbine fuel, Other petroleum products: gasoline components, petroleum fractions and/or products with a boiling range of 30°C - 350°C Copper strip corrosion Visual method corrosion class PN-EN ISO 2160:2004","technique_en":"Visual method","test_object_en":"Liquid fuels: diesel fuel, unleaded petrol, aviation gasoline, aviation turbine fuel, Other petroleum products: gasoline components, petroleum fractions and/or products with a boiling range of 30°C - 350°C","search_zh":"液体燃料：柴油、无铅汽油、航空汽油、航空涡轮发动机燃料；其他石油加工品：汽油组分、沸程 30°C - 350°C 的石油馏分和/或产品 铜片腐蚀 目视法 腐蚀等级 PN-EN ISO 2160:2004","technique_zh":"目视法","parameters_zh":[{"name":"腐蚀等级","range":"(1 – 4)"}],"methodology_zh":"铜片腐蚀","test_object_zh":"液体燃料：柴油、无铅汽油、航空汽油、航空涡轮发动机燃料；其他石油加工品：汽油组分、沸程 30°C - 350°C 的石油馏分和/或产品"},{"_id":"6a836fb9af14b9c0e7b1eb51","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, benzyna lotnicza, paliwo do turbinowych silników lotniczych, Inne przetwory naftowe: komponenty benzynowe, frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30°C - 350°C","methodology":"Działanie korodujące na miedź","parameters":[{"name":"klasa korozji","range":"(1a – 4c)"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Działanie korodujące na miedź\nklasa korozji (1a – 4c)\nMetoda wizualna","reference":"ASTM D 130-19","norm_bases":["ASTM D 130-19"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, benzyna lotnicza, paliwo do turbinowych silników lotniczych, Inne przetwory naftowe: komponenty benzynowe, frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30°C - 350°C Działanie korodujące na miedź\nklasa korozji (1a – 4c)\nMetoda wizualna ASTM D 130-19 Paliwa ciekle: olej napedowy, benzyna bezolowiowa, benzyna lotnicza, paliwo do turbinowych silnikow lotniczych, Inne przetwory naftowe: komponenty benzynowe, frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30°C - 350°C Dzialanie korodujace na miedz\nklasa korozji (1a – 4c)\nMetoda wizualna ASTM D 130-19","categories":["petro","materials"],"row_index":58,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Copper strip corrosion","parameters_en":[{"name":"corrosion class","range":"(1a – 4c)"}],"search_en":"Liquid fuels: diesel fuel, unleaded petrol, aviation gasoline, aviation turbine fuel, Other petroleum products: gasoline components, petroleum fractions and/or products with a boiling range of 30°C - 350°C Copper strip corrosion Visual method corrosion class ASTM D 130-19","technique_en":"Visual method","test_object_en":"Liquid fuels: diesel fuel, unleaded petrol, aviation gasoline, aviation turbine fuel, Other petroleum products: gasoline components, petroleum fractions and/or products with a boiling range of 30°C - 350°C","search_zh":"液体燃料：柴油、无铅汽油、航空汽油、航空涡轮发动机燃料；其他石油加工品：汽油组分、沸程 30°C - 350°C 的石油馏分和/或产品 铜片腐蚀 目视法 腐蚀等级 ASTM D 130-19","technique_zh":"目视法","parameters_zh":[{"name":"腐蚀等级","range":"(1a – 4c)"}],"methodology_zh":"铜片腐蚀","test_object_zh":"液体燃料：柴油、无铅汽油、航空汽油、航空涡轮发动机燃料；其他石油加工品：汽油组分、沸程 30°C - 350°C 的石油馏分和/或产品"},{"_id":"6a836fb9af14b9c0e7b1eb52","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, benzyna lotnicza, paliwo do turbinowych silników lotniczych, Inne przetwory naftowe: komponenty benzynowe, frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30°C - 350°C","methodology":"Zawartość siarki","parameters":[{"name":"Zakres","range":"(20,0 – 500) mg/kg"}],"technique":"Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali","techniques":["Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali"],"computed":[],"activity":"Zawartość siarki\nZakres (20,0 – 500) mg/kg\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali","reference":"PN-EN ISO 20884:2020-03 +A1:2022-03","norm_bases":["PN-EN ISO 20884:2020-03 +A1:2022-03"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, benzyna lotnicza, paliwo do turbinowych silników lotniczych, Inne przetwory naftowe: komponenty benzynowe, frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30°C - 350°C Zawartość siarki\nZakres (20,0 – 500) mg/kg\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali PN-EN ISO 20884:2020-03 +A1:2022-03 Paliwa ciekle: olej napedowy, benzyna bezolowiowa, benzyna lotnicza, paliwo do turbinowych silnikow lotniczych, Inne przetwory naftowe: komponenty benzynowe, frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30°C - 350°C Zawartosc siarki\nZakres (20,0 – 500) mg/kg\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersja fali PN-EN ISO 20884:2020-03 +A1:2022-03","categories":["petro"],"row_index":59,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfur content","parameters_en":[{"name":"Range","range":"(20,0 – 500) mg/kg"}],"search_en":"Liquid fuels: diesel fuel, unleaded petrol, aviation gasoline, aviation turbine fuel, Other petroleum products: gasoline components, petroleum fractions and/or products with a boiling range of 30°C - 350°C Sulfur content Wavelength-dispersive X-ray fluorescence spectrometry Range PN-EN ISO 20884:2020-03 +A1:2022-03","technique_en":"Wavelength-dispersive X-ray fluorescence spectrometry","test_object_en":"Liquid fuels: diesel fuel, unleaded petrol, aviation gasoline, aviation turbine fuel, Other petroleum products: gasoline components, petroleum fractions and/or products with a boiling range of 30°C - 350°C","parameters_zh":[{"name":"范围","range":"(20,0 – 500) mg/kg"}],"search_zh":"液体燃料：柴油、无铅汽油、航空汽油、航空涡轮发动机燃料；其他石油加工品：汽油组分、沸程 30°C - 350°C 的石油馏分和/或产品 硫含量 波长色散X射线荧光光谱法 范围 PN-EN ISO 20884:2020-03 +A1:2022-03","methodology_zh":"硫含量","technique_zh":"波长色散X射线荧光光谱法","test_object_zh":"液体燃料：柴油、无铅汽油、航空汽油、航空涡轮发动机燃料；其他石油加工品：汽油组分、沸程 30°C - 350°C 的石油馏分和/或产品"},{"_id":"6a836fb9af14b9c0e7b1eb53","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, benzyna lotnicza, paliwo do turbinowych silników lotniczych, Inne przetwory naftowe: komponenty benzynowe, frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30°C - 350°C","methodology":"Zawartość siarki","parameters":[{"name":"Zakres","range":"(0,0020 – 2,50) % (m/m)"}],"technique":"Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali","techniques":["Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali"],"computed":[],"activity":"Zawartość siarki\nZakres (0,0020 – 2,50) % (m/m)\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali","reference":"PN-EN ISO 14596:2009","norm_bases":["PN-EN ISO 14596:2009"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, benzyna lotnicza, paliwo do turbinowych silników lotniczych, Inne przetwory naftowe: komponenty benzynowe, frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30°C - 350°C Zawartość siarki\nZakres (0,0020 – 2,50) % (m/m)\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali PN-EN ISO 14596:2009 Paliwa ciekle: olej napedowy, benzyna bezolowiowa, benzyna lotnicza, paliwo do turbinowych silnikow lotniczych, Inne przetwory naftowe: komponenty benzynowe, frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30°C - 350°C Zawartosc siarki\nZakres (0,0020 – 2,50) % (m/m)\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersja fali PN-EN ISO 14596:2009","categories":["petro"],"row_index":60,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfur content","parameters_en":[{"name":"Range","range":"(0,0020 – 2,50) % (m/m)"}],"search_en":"Liquid fuels: diesel fuel, unleaded petrol, aviation gasoline, aviation turbine fuel, Other petroleum products: gasoline components, petroleum fractions and/or products with a boiling range of 30°C - 350°C Sulfur content Wavelength-dispersive X-ray fluorescence spectrometry Range PN-EN ISO 14596:2009","technique_en":"Wavelength-dispersive X-ray fluorescence spectrometry","test_object_en":"Liquid fuels: diesel fuel, unleaded petrol, aviation gasoline, aviation turbine fuel, Other petroleum products: gasoline components, petroleum fractions and/or products with a boiling range of 30°C - 350°C","parameters_zh":[{"name":"范围","range":"(0,0020 – 2,50) % (m/m)"}],"search_zh":"液体燃料：柴油、无铅汽油、航空汽油、航空涡轮发动机燃料；其他石油加工品：汽油组分、沸程 30°C - 350°C 的石油馏分和/或产品 硫含量 波长色散X射线荧光光谱法 范围 PN-EN ISO 14596:2009","methodology_zh":"硫含量","technique_zh":"波长色散X射线荧光光谱法","test_object_zh":"液体燃料：柴油、无铅汽油、航空汽油、航空涡轮发动机燃料；其他石油加工品：汽油组分、沸程 30°C - 350°C 的石油馏分和/或产品"},{"_id":"6a836fb9af14b9c0e7b1eb54","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa, paliwo do turbinowych silników lotniczych","methodology":"Zawartość grup węglowodorów","parameters":[{"name":"węglowodory aromatyczne"},{"name":"Zakres","range":"(5,0 – 70,0) %(v/v)"},{"name":"węglowodory olefinowe","range":"(1,0 – 55,0) %(v/v)"}],"technique":"Metoda chromatografii żelowej (FIA)","techniques":["Metoda chromatografii żelowej (FIA)"],"computed":[],"activity":"Zawartość grup węglowodorów\nZakres:\nwęglowodory aromatyczne\nZakres (5,0 – 70,0) %(v/v)\nwęglowodory olefinowe (1,0 – 55,0) %(v/v)\nMetoda chromatografii żelowej (FIA)","reference":"ASTM D 1319-20a | PN-EN 15553:2022-05+A1:2025-05","norm_bases":["ASTM D 1319-20a","PN-EN 15553:2022-05+A1:2025-05"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa, paliwo do turbinowych silników lotniczych Zawartość grup węglowodorów\nZakres:\nwęglowodory aromatyczne\nZakres (5,0 – 70,0) %(v/v)\nwęglowodory olefinowe (1,0 – 55,0) %(v/v)\nMetoda chromatografii żelowej (FIA) ASTM D 1319-20a | PN-EN 15553:2022-05+A1:2025-05 Paliwa ciekle: benzyna bezolowiowa, paliwo do turbinowych silnikow lotniczych Zawartosc grup weglowodorow\nZakres:\nweglowodory aromatyczne\nZakres (5,0 – 70,0) %(v/v)\nweglowodory olefinowe (1,0 – 55,0) %(v/v)\nMetoda chromatografii zelowej (FIA) ASTM D 1319-20a | PN-EN 15553:2022-05+A1:2025-05","categories":["petro"],"row_index":61,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrocarbon group content","parameters_en":[{"name":"aromatic hydrocarbons"},{"name":"Range","range":"(5,0 – 70,0) %(v/v)"},{"name":"olefinic hydrocarbons","range":"(1,0 – 55,0) %(v/v)"}],"search_en":"Liquid fuels: unleaded petrol, aviation turbine fuel Hydrocarbon group content Gel chromatography method (FIA) aromatic hydrocarbons Range olefinic hydrocarbons ASTM D 1319-20a | PN-EN 15553:2022-05+A1:2025-05","technique_en":"Gel chromatography method (FIA)","test_object_en":"Liquid fuels: unleaded petrol, aviation turbine fuel","parameters_zh":[{"name":"芳香烃"},{"name":"范围","range":"(5,0 – 70,0) %(v/v)"},{"name":"烯烃","range":"(1,0 – 55,0) %(v/v)"}],"search_zh":"烃族组成含量 凝胶色谱法（FIA） 芳香烃 范围 烯烃 ASTM D 1319-20a | PN-EN 15553:2022-05+A1:2025-05","methodology_zh":"烃族组成含量","technique_zh":"凝胶色谱法（FIA）"},{"_id":"6a836fb9af14b9c0e7b1eb55","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, benzyna lotnicza, paliwo do turbinowych silników lotniczych, Inne przetwory naftowe: frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30°C - 350°C","methodology":"Skład frakcyjny","parameters":[{"name":"Zakres","range":"(30,0 – 360,0) °C"}],"technique":"Metoda destylacyjna automatyczna","techniques":["Metoda destylacyjna automatyczna"],"computed":[],"activity":"Skład frakcyjny\nZakres (30,0 – 360,0) °C\nMetoda destylacyjna automatyczna","reference":"ASTM D 86-23aɛ2","norm_bases":["ASTM D 86-23aɛ2"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, benzyna lotnicza, paliwo do turbinowych silników lotniczych, Inne przetwory naftowe: frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30°C - 350°C Skład frakcyjny\nZakres (30,0 – 360,0) °C\nMetoda destylacyjna automatyczna ASTM D 86-23aɛ2 Paliwa ciekle: olej napedowy, benzyna bezolowiowa, benzyna lotnicza, paliwo do turbinowych silnikow lotniczych, Inne przetwory naftowe: frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30°C - 350°C Sklad frakcyjny\nZakres (30,0 – 360,0) °C\nMetoda destylacyjna automatyczna ASTM D 86-23aɛ2","categories":["petro"],"row_index":62,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fractional composition","parameters_en":[{"name":"Range","range":"(30,0 – 360,0) °C"}],"search_en":"Liquid fuels: diesel fuel, unleaded petrol, aviation gasoline, aviation turbine fuel, Other petroleum products: petroleum fractions and/or products with a boiling range of 30°C - 350°C Fractional composition Automatic distillation method Range ASTM D 86-23aɛ2","technique_en":"Automatic distillation method","test_object_en":"Liquid fuels: diesel fuel, unleaded petrol, aviation gasoline, aviation turbine fuel, Other petroleum products: petroleum fractions and/or products with a boiling range of 30°C - 350°C","parameters_zh":[{"name":"范围","range":"(30,0 – 360,0) °C"}],"search_zh":"馏程组成 范围 ASTM D 86-23aɛ2","methodology_zh":"馏程组成"},{"_id":"6a836fb9af14b9c0e7b1eb56","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, benzyna lotnicza, paliwo do turbinowych silników lotniczych, Inne przetwory naftowe: frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30°C - 350°C","methodology":"Zawartość siarki","parameters":[{"name":"Zakres","range":"(3,0 – 500) mg/kg"}],"technique":"Metoda fluorescencji w nadfiolecie","techniques":["Metoda fluorescencji w nadfiolecie"],"computed":[],"activity":"Zawartość siarki\nZakres (3,0 – 500) mg/kg\nMetoda fluorescencji w nadfiolecie","reference":"PN-EN ISO 20846:2020-03","norm_bases":["PN-EN ISO 20846:2020-03"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, benzyna lotnicza, paliwo do turbinowych silników lotniczych, Inne przetwory naftowe: frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30°C - 350°C Zawartość siarki\nZakres (3,0 – 500) mg/kg\nMetoda fluorescencji w nadfiolecie PN-EN ISO 20846:2020-03 Paliwa ciekle: olej napedowy, benzyna bezolowiowa, benzyna lotnicza, paliwo do turbinowych silnikow lotniczych, Inne przetwory naftowe: frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30°C - 350°C Zawartosc siarki\nZakres (3,0 – 500) mg/kg\nMetoda fluorescencji w nadfiolecie PN-EN ISO 20846:2020-03","categories":["petro"],"row_index":63,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfur content","parameters_en":[{"name":"Range","range":"(3,0 – 500) mg/kg"}],"search_en":"Liquid fuels: diesel fuel, unleaded petrol, aviation gasoline, aviation turbine fuel, Other petroleum products: petroleum fractions and/or products with a boiling range of 30°C - 350°C Sulfur content Ultraviolet fluorescence method Range PN-EN ISO 20846:2020-03","technique_en":"Ultraviolet fluorescence method","test_object_en":"Liquid fuels: diesel fuel, unleaded petrol, aviation gasoline, aviation turbine fuel, Other petroleum products: petroleum fractions and/or products with a boiling range of 30°C - 350°C","parameters_zh":[{"name":"范围","range":"(3,0 – 500) mg/kg"}],"search_zh":"硫含量 紫外荧光法 范围 PN-EN ISO 20846:2020-03","methodology_zh":"硫含量","technique_zh":"紫外荧光法"},{"_id":"6a836fb9af14b9c0e7b1eb57","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, benzyna lotnicza, paliwo do turbinowych silników lotniczych, Inne przetwory naftowe: frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30°C - 350°C","methodology":"Zawartość siarki","parameters":[{"name":"Zakres","range":"(1,0 – 1000) mg/kg"}],"technique":"Metoda fluorescencji w nadfiolecie","techniques":["Metoda fluorescencji w nadfiolecie"],"computed":[],"activity":"Zawartość siarki\nZakres (1,0 – 1000) mg/kg\nMetoda fluorescencji w nadfiolecie","reference":"ASTM D 5453-24","norm_bases":["ASTM D 5453-24"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, benzyna lotnicza, paliwo do turbinowych silników lotniczych, Inne przetwory naftowe: frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30°C - 350°C Zawartość siarki\nZakres (1,0 – 1000) mg/kg\nMetoda fluorescencji w nadfiolecie ASTM D 5453-24 Paliwa ciekle: olej napedowy, benzyna bezolowiowa, benzyna lotnicza, paliwo do turbinowych silnikow lotniczych, Inne przetwory naftowe: frakcje i/lub produkty naftowe o zakresie temperatur wrzenia 30°C - 350°C Zawartosc siarki\nZakres (1,0 – 1000) mg/kg\nMetoda fluorescencji w nadfiolecie ASTM D 5453-24","categories":["petro"],"row_index":64,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfur content","parameters_en":[{"name":"Range","range":"(1,0 – 1000) mg/kg"}],"search_en":"Liquid fuels: diesel fuel, unleaded petrol, aviation gasoline, aviation turbine fuel, Other petroleum products: petroleum fractions and/or products with a boiling range of 30°C - 350°C Sulfur content Ultraviolet fluorescence method Range ASTM D 5453-24","technique_en":"Ultraviolet fluorescence method","test_object_en":"Liquid fuels: diesel fuel, unleaded petrol, aviation gasoline, aviation turbine fuel, Other petroleum products: petroleum fractions and/or products with a boiling range of 30°C - 350°C","parameters_zh":[{"name":"范围","range":"(1,0 – 1000) mg/kg"}],"search_zh":"硫含量 紫外荧光法 范围 ASTM D 5453-24","methodology_zh":"硫含量","technique_zh":"紫外荧光法"},{"_id":"6a836fb9af14b9c0e7b1eb58","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych","methodology":"Zawartość siarki całkowitej","parameters":[{"name":"Zakres","range":"(0,0050 – 0,300) %(m/m)"}],"technique":"Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii","techniques":["Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii"],"computed":[],"activity":"Zawartość siarki całkowitej\nZakres (0,0050 – 0,300) %(m/m)\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii","reference":"ASTM D 4294-24","norm_bases":["ASTM D 4294-24"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych Zawartość siarki całkowitej\nZakres (0,0050 – 0,300) %(m/m)\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii ASTM D 4294-24 Paliwa ciekle: paliwo do turbinowych silnikow lotniczych Zawartosc siarki calkowitej\nZakres (0,0050 – 0,300) %(m/m)\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersja energii ASTM D 4294-24","categories":["petro"],"row_index":65,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total sulfur content","parameters_en":[{"name":"Range","range":"(0,0050 – 0,300) %(m/m)"}],"search_en":"Liquid fuels: aviation turbine fuel Total sulfur content Energy-dispersive X-ray fluorescence spectrometry Range ASTM D 4294-24","technique_en":"Energy-dispersive X-ray fluorescence spectrometry","test_object_en":"Liquid fuels: aviation turbine fuel","methodology_zh":"全硫含量","parameters_zh":[{"name":"范围","range":"(0,0050 – 0,300) %(m/m)"}],"search_zh":"液体燃料：航空涡轮发动机燃料 全硫含量 能量色散X射线荧光光谱法 范围 ASTM D 4294-24","test_object_zh":"液体燃料：航空涡轮发动机燃料","technique_zh":"能量色散X射线荧光光谱法"},{"_id":"6a836fb9af14b9c0e7b1eb59","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych","methodology":"Największa wysokość niekopcącego płomienia","parameters":[{"name":"Zakres","range":"(17,0 – 30,0) mm"}],"technique":"Metoda optyczna; Metoda wizualna","techniques":["Metoda optyczna","Metoda wizualna"],"computed":[],"activity":"Największa wysokość niekopcącego płomienia\nZakres (17,0 – 30,0) mm\nMetoda optyczna; Metoda wizualna","reference":"ASTM D 1322-25","norm_bases":["ASTM D 1322-25"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych Największa wysokość niekopcącego płomienia\nZakres (17,0 – 30,0) mm\nMetoda optyczna; Metoda wizualna ASTM D 1322-25 Paliwa ciekle: paliwo do turbinowych silnikow lotniczych Najwieksza wysokosc niekopcacego plomienia\nZakres (17,0 – 30,0) mm\nMetoda optyczna; Metoda wizualna ASTM D 1322-25","categories":["petro"],"row_index":66,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Maximum height of a smokeless flame","parameters_en":[{"name":"Range","range":"(17,0 – 30,0) mm"}],"search_en":"Liquid fuels: aviation turbine fuel Maximum height of a smokeless flame Optical method; Visual method Range ASTM D 1322-25","technique_en":"Optical method; Visual method","test_object_en":"Liquid fuels: aviation turbine fuel","parameters_zh":[{"name":"范围","range":"(17,0 – 30,0) mm"}],"search_zh":"液体燃料：航空涡轮发动机燃料 范围 ASTM D 1322-25","test_object_zh":"液体燃料：航空涡轮发动机燃料"},{"_id":"6a836fb9af14b9c0e7b1eb5a","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych","methodology":"Kwasowość","parameters":[{"name":"Zakres","range":"(0,0001 – 0,100) mg KOH/g"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Kwasowość\nZakres (0,0001 – 0,100) mg KOH/g\nMetoda miareczkowa","reference":"ASTM D 3242-23","norm_bases":["ASTM D 3242-23"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych Kwasowość\nZakres (0,0001 – 0,100) mg KOH/g\nMetoda miareczkowa ASTM D 3242-23 Paliwa ciekle: paliwo do turbinowych silnikow lotniczych Kwasowosc\nZakres (0,0001 – 0,100) mg KOH/g\nMetoda miareczkowa ASTM D 3242-23","categories":["petro"],"row_index":67,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Acidity","parameters_en":[{"name":"Range","range":"(0,0001 – 0,100) mg KOH/g"}],"search_en":"Liquid fuels: aviation turbine fuel Acidity Titrimetric method Range ASTM D 3242-23","technique_en":"Titrimetric method","test_object_en":"Liquid fuels: aviation turbine fuel","methodology_zh":"酸度","parameters_zh":[{"name":"范围","range":"(0,0001 – 0,100) mg KOH/g"}],"search_zh":"液体燃料：航空涡轮发动机燃料 酸度 滴定法 范围 ASTM D 3242-23","technique_zh":"滴定法","test_object_zh":"液体燃料：航空涡轮发动机燃料"},{"_id":"6a836fb9af14b9c0e7b1eb5b","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych","methodology":"Wartość opałowa (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wartość opałowa (z obliczeń)","reference":"ASTM D 3338/D 3338M-20a","norm_bases":["ASTM D 3338/D 3338M-20a"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych Wartość opałowa (z obliczeń) ASTM D 3338/D 3338M-20a Paliwa ciekle: paliwo do turbinowych silnikow lotniczych Wartosc opalowa (z obliczen) ASTM D 3338/D 3338M-20a","categories":["petro"],"row_index":68,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Net calorific value (calculated)","search_en":"Liquid fuels: aviation turbine fuel Net calorific value (calculated) ASTM D 3338/D 3338M-20a","test_object_en":"Liquid fuels: aviation turbine fuel","methodology_zh":"低位发热量（计算值）","search_zh":"液体燃料：航空涡轮发动机燃料 低位发热量（计算值） ASTM D 3338/D 3338M-20a","test_object_zh":"液体燃料：航空涡轮发动机燃料"},{"_id":"6a836fb9af14b9c0e7b1eb5c","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych","methodology":"Stabilność termooksydacyjna w temperaturze 260 °C","parameters":[{"name":"Osady na rurze 0 – 4 A, P Spadek ciśnienia","range":"(0,1 – 200) mmHg"}],"technique":"Metoda JFTOT","techniques":["Metoda JFTOT"],"computed":[],"activity":"Stabilność termooksydacyjna w temperaturze 260 °C\nOsady na rurze 0 – 4 A, P Spadek ciśnienia (0,1 – 200) mmHg\nMetoda JFTOT","reference":"ASTM D 3241-24","norm_bases":["ASTM D 3241-24"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych Stabilność termooksydacyjna w temperaturze 260 °C\nOsady na rurze 0 – 4 A, P Spadek ciśnienia (0,1 – 200) mmHg\nMetoda JFTOT ASTM D 3241-24 Paliwa ciekle: paliwo do turbinowych silnikow lotniczych Stabilnosc termooksydacyjna w temperaturze 260 °C\nOsady na rurze 0 – 4 A, P Spadek cisnienia (0,1 – 200) mmHg\nMetoda JFTOT ASTM D 3241-24","categories":["water","petro"],"row_index":69,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Thermo-oxidative stability at 260 °C","parameters_en":[{"name":"Deposits on the tube 0 – 4 A, P Pressure drop","range":"(0,1 – 200) mmHg"}],"search_en":"Liquid fuels: aviation turbine fuel Thermo-oxidative stability at 260 °C JFTOT method Deposits on the tube 0 – 4 A, P Pressure drop ASTM D 3241-24","technique_en":"JFTOT method","test_object_en":"Liquid fuels: aviation turbine fuel","search_zh":"液体燃料：航空涡轮发动机燃料 喷射燃料热氧化安定性法（JFTOT） ASTM D 3241-24","test_object_zh":"液体燃料：航空涡轮发动机燃料","technique_zh":"喷射燃料热氧化安定性法（JFTOT）"},{"_id":"6a836fb9af14b9c0e7b1eb5d","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych","methodology":"Właściwości separacyjne wody","parameters":[{"name":"Zakres","range":"70 – 100"}],"technique":"Metoda turbidymetryczna","techniques":["Metoda turbidymetryczna"],"computed":[],"activity":"Właściwości separacyjne wody\nZakres 70 – 100\nMetoda turbidymetryczna","reference":"ASTM D 3948-22","norm_bases":["ASTM D 3948-22"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych Właściwości separacyjne wody\nZakres 70 – 100\nMetoda turbidymetryczna ASTM D 3948-22 Paliwa ciekle: paliwo do turbinowych silnikow lotniczych Wlasciwosci separacyjne wody\nZakres 70 – 100\nMetoda turbidymetryczna ASTM D 3948-22","categories":["petro","water"],"row_index":70,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water separation properties","parameters_en":[{"name":"Range","range":"70 – 100"}],"search_en":"Liquid fuels: aviation turbine fuel Water separation properties Turbidimetric method Range ASTM D 3948-22","technique_en":"Turbidimetric method","test_object_en":"Liquid fuels: aviation turbine fuel","parameters_zh":[{"name":"范围","range":"70 – 100"}],"search_zh":"液体燃料：航空涡轮发动机燃料 浊度法 范围 ASTM D 3948-22","technique_zh":"浊度法","test_object_zh":"液体燃料：航空涡轮发动机燃料"},{"_id":"6a836fb9af14b9c0e7b1eb5e","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych","methodology":"Smarność","parameters":[{"name":"Zakres","range":"(0,40 – 0,85) mm"}],"technique":"Metoda BOCLE","techniques":["Metoda BOCLE"],"computed":[],"activity":"Smarność\nZakres (0,40 – 0,85) mm\nMetoda BOCLE","reference":"ASTM D 5001-25","norm_bases":["ASTM D 5001-25"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych Smarność\nZakres (0,40 – 0,85) mm\nMetoda BOCLE ASTM D 5001-25 Paliwa ciekle: paliwo do turbinowych silnikow lotniczych Smarnosc\nZakres (0,40 – 0,85) mm\nMetoda BOCLE ASTM D 5001-25","categories":["petro"],"row_index":71,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Lubricity","parameters_en":[{"name":"Range","range":"(0,40 – 0,85) mm"}],"search_en":"Liquid fuels: aviation turbine fuel Lubricity BOCLE method Range ASTM D 5001-25","technique_en":"BOCLE method","test_object_en":"Liquid fuels: aviation turbine fuel","parameters_zh":[{"name":"范围","range":"(0,40 – 0,85) mm"}],"search_zh":"液体燃料：航空涡轮发动机燃料 润滑性 范围 ASTM D 5001-25","test_object_zh":"液体燃料：航空涡轮发动机燃料","methodology_zh":"润滑性"},{"_id":"6a836fb9af14b9c0e7b1eb5f","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych","methodology":"Zawartość cząstek stałych przy użyciu przenośnego automatycznego licznika cząstek","parameters":[{"name":"Zakres","range":"dla cząstek o średnicy:"},{"name":"≥ 4 μm","range":"(216 – 45061) liczba cząstek"},{"name":"≥ 6 μm","range":"(74 – 22483) liczba cząstek"},{"name":"≥ 14 μm","range":"(9 – 4105) liczba cząstek"},{"name":"≥ 21 μm","range":"(2 – 1444) liczba cząstek"},{"name":"≥ 25 μm","range":"(1 – 776) liczba cząstek"},{"name":"≥ 30 μm","range":"(1 – 365) liczba cząstek"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Zawartość cząstek stałych przy użyciu przenośnego automatycznego licznika cząstek\nZakres:\nZakres dla cząstek o średnicy:\n≥ 4 μm (216 – 45061) liczba cząstek\n≥ 6 μm (74 – 22483) liczba cząstek\n≥ 14 μm (9 – 4105) liczba cząstek\n≥ 21 μm (2 – 1444) liczba cząstek\n≥ 25 μm (1 – 776) liczba cząstek\n≥ 30 μm (1 – 365) liczba cząstek\nMetoda optyczna","reference":"IP 565-13","norm_bases":["IP 565-13"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych Zawartość cząstek stałych przy użyciu przenośnego automatycznego licznika cząstek\nZakres:\nZakres dla cząstek o średnicy:\n≥ 4 μm (216 – 45061) liczba cząstek\n≥ 6 μm (74 – 22483) liczba cząstek\n≥ 14 μm (9 – 4105) liczba cząstek\n≥ 21 μm (2 – 1444) liczba cząstek\n≥ 25 μm (1 – 776) liczba cząstek\n≥ 30 μm (1 – 365) liczba cząstek\nMetoda optyczna IP 565-13 Paliwa ciekle: paliwo do turbinowych silnikow lotniczych Zawartosc czastek stalych przy uzyciu przenosnego automatycznego licznika czastek\nZakres:\nZakres dla czastek o srednicy:\n≥ 4 μm (216 – 45061) liczba czastek\n≥ 6 μm (74 – 22483) liczba czastek\n≥ 14 μm (9 – 4105) liczba czastek\n≥ 21 μm (2 – 1444) liczba czastek\n≥ 25 μm (1 – 776) liczba czastek\n≥ 30 μm (1 – 365) liczba czastek\nMetoda optyczna IP 565-13","categories":["petro"],"row_index":72,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Solid particle content using a portable automatic particle counter","parameters_en":[{"name":"Range","range":"dla cząstek o średnicy:"},{"name":"≥ 4 μm","range":"(216 – 45061) liczba cząstek"},{"name":"≥ 6 μm","range":"(74 – 22483) liczba cząstek"},{"name":"≥ 14 μm","range":"(9 – 4105) liczba cząstek"},{"name":"≥ 21 μm","range":"(2 – 1444) liczba cząstek"},{"name":"≥ 25 μm","range":"(1 – 776) liczba cząstek"},{"name":"≥ 30 μm","range":"(1 – 365) liczba cząstek"}],"search_en":"Liquid fuels: aviation turbine fuel Solid particle content using a portable automatic particle counter Optical method Range ≥ 4 μm ≥ 6 μm ≥ 14 μm ≥ 21 μm ≥ 25 μm ≥ 30 μm IP 565-13","technique_en":"Optical method","test_object_en":"Liquid fuels: aviation turbine fuel","parameters_zh":[{"name":"范围","range":"dla cząstek o średnicy:"},{"name":"≥ 4 μm","range":"(216 – 45061) liczba cząstek"},{"name":"≥ 6 μm","range":"(74 – 22483) liczba cząstek"},{"name":"≥ 14 μm","range":"(9 – 4105) liczba cząstek"},{"name":"≥ 21 μm","range":"(2 – 1444) liczba cząstek"},{"name":"≥ 25 μm","range":"(1 – 776) liczba cząstek"},{"name":"≥ 30 μm","range":"(1 – 365) liczba cząstek"}],"search_zh":"液体燃料：航空涡轮发动机燃料 光学法 范围 IP 565-13","technique_zh":"光学法","test_object_zh":"液体燃料：航空涡轮发动机燃料"},{"_id":"6a836fb9af14b9c0e7b1eb60","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych","methodology":"Zawartość wodoru (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość wodoru (z obliczeń)","reference":"ASTM D 3343-22","norm_bases":["ASTM D 3343-22"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych Zawartość wodoru (z obliczeń) ASTM D 3343-22 Paliwa ciekle: paliwo do turbinowych silnikow lotniczych Zawartosc wodoru (z obliczen) ASTM D 3343-22","categories":["petro"],"row_index":73,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrogen content (calculated)","search_en":"Liquid fuels: aviation turbine fuel Hydrogen content (calculated) ASTM D 3343-22","test_object_en":"Liquid fuels: aviation turbine fuel","search_zh":"液体燃料：航空涡轮发动机燃料 ASTM D 3343-22","test_object_zh":"液体燃料：航空涡轮发动机燃料"},{"_id":"6a836fb9af14b9c0e7b1eb61","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych","methodology":"Zawartość dodatku przeciwoblodzeniowego","parameters":[{"name":"Zakres","range":"(0,01 – 0,25) %(v/v)"}],"technique":"Metoda refraktometryczna","techniques":["Metoda refraktometryczna"],"computed":[],"activity":"Zawartość dodatku przeciwoblodzeniowego\nZakres (0,01 – 0,25) %(v/v)\nMetoda refraktometryczna","reference":"ASTM D 5006-25","norm_bases":["ASTM D 5006-25"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych Zawartość dodatku przeciwoblodzeniowego\nZakres (0,01 – 0,25) %(v/v)\nMetoda refraktometryczna ASTM D 5006-25 Paliwa ciekle: paliwo do turbinowych silnikow lotniczych Zawartosc dodatku przeciwoblodzeniowego\nZakres (0,01 – 0,25) %(v/v)\nMetoda refraktometryczna ASTM D 5006-25","categories":["petro"],"row_index":74,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Anti-icing additive content","parameters_en":[{"name":"Range","range":"(0,01 – 0,25) %(v/v)"}],"search_en":"Liquid fuels: aviation turbine fuel Anti-icing additive content Refractometric method Range ASTM D 5006-25","technique_en":"Refractometric method","test_object_en":"Liquid fuels: aviation turbine fuel","parameters_zh":[{"name":"范围","range":"(0,01 – 0,25) %(v/v)"}],"search_zh":"液体燃料：航空涡轮发动机燃料 折射法 范围 ASTM D 5006-25","technique_zh":"折射法","test_object_zh":"液体燃料：航空涡轮发动机燃料"},{"_id":"6a836fb9af14b9c0e7b1eb62","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych","methodology":"Zawartość estrów metylowych kwasów tłuszczowych (FAME)","parameters":[{"name":"Zakres","range":"(10,0 – 100,0) mg/kg"}],"technique":"Metoda spektrometrii w podczerwieni","techniques":["Metoda spektrometrii w podczerwieni"],"computed":[],"activity":"Zawartość estrów metylowych kwasów tłuszczowych (FAME)\nZakres (10,0 – 100,0) mg/kg\nMetoda spektrometrii w podczerwieni","reference":"ASTM D 7797-23","norm_bases":["ASTM D 7797-23"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych Zawartość estrów metylowych kwasów tłuszczowych (FAME)\nZakres (10,0 – 100,0) mg/kg\nMetoda spektrometrii w podczerwieni ASTM D 7797-23 Paliwa ciekle: paliwo do turbinowych silnikow lotniczych Zawartosc estrow metylowych kwasow tluszczowych (FAME)\nZakres (10,0 – 100,0) mg/kg\nMetoda spektrometrii w podczerwieni ASTM D 7797-23","categories":["petro"],"row_index":75,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fatty acid methyl esters (FAME) content","parameters_en":[{"name":"Range","range":"(10,0 – 100,0) mg/kg"}],"search_en":"Liquid fuels: aviation turbine fuel Fatty acid methyl esters (FAME) content Infrared spectrometry method Range ASTM D 7797-23","technique_en":"Infrared spectrometry method","test_object_en":"Liquid fuels: aviation turbine fuel","parameters_zh":[{"name":"范围","range":"(10,0 – 100,0) mg/kg"}],"search_zh":"液体燃料：航空涡轮发动机燃料 脂肪酸甲酯（FAME）含量 红外光谱法 范围 ASTM D 7797-23","technique_zh":"红外光谱法","test_object_zh":"液体燃料：航空涡轮发动机燃料","methodology_zh":"脂肪酸甲酯（FAME）含量"},{"_id":"6a836fb9af14b9c0e7b1eb63","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych","methodology":"Wygląd","parameters":[],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Wygląd\nMetoda wizualna","reference":"NO-91-A258-1:2024 p. 2.1","norm_bases":["NO-91-A258-1:2024 p. 2.1"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych Wygląd\nMetoda wizualna NO-91-A258-1:2024 p. 2.1 Paliwa ciekle: paliwo do turbinowych silnikow lotniczych Wyglad\nMetoda wizualna NO-91-A258-1:2024 p. 2.1","categories":["petro"],"row_index":76,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Appearance","search_en":"Liquid fuels: aviation turbine fuel Appearance Visual method NO-91-A258-1:2024 p. 2.1","technique_en":"Visual method","test_object_en":"Liquid fuels: aviation turbine fuel","search_zh":"液体燃料：航空涡轮发动机燃料 外观 目视法 NO-91-A258-1:2024 p. 2.1","technique_zh":"目视法","test_object_zh":"液体燃料：航空涡轮发动机燃料","methodology_zh":"外观"},{"_id":"6a836fb9af14b9c0e7b1eb64","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych, Inne przetwory naftowe: produkty naftowe o zakresie temperatur wrzenia 15°C - 370°C","methodology":"Temperatura zapłonu","parameters":[{"name":"Zakres","range":"(4,0 – 70,0) °C"}],"technique":"Metoda zamkniętego tygla TAG","techniques":["Metoda zamkniętego tygla TAG"],"computed":[],"activity":"Temperatura zapłonu\nZakres (4,0 – 70,0) °C\nMetoda zamkniętego tygla TAG","reference":"ASTM D 56-22","norm_bases":["ASTM D 56-22"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych, Inne przetwory naftowe: produkty naftowe o zakresie temperatur wrzenia 15°C - 370°C Temperatura zapłonu\nZakres (4,0 – 70,0) °C\nMetoda zamkniętego tygla TAG ASTM D 56-22 Paliwa ciekle: paliwo do turbinowych silnikow lotniczych, Inne przetwory naftowe: produkty naftowe o zakresie temperatur wrzenia 15°C - 370°C Temperatura zaplonu\nZakres (4,0 – 70,0) °C\nMetoda zamknietego tygla TAG ASTM D 56-22","categories":["petro"],"row_index":77,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Flash point","parameters_en":[{"name":"Range","range":"(4,0 – 70,0) °C"}],"search_en":"Liquid fuels: aviation turbine fuel, Other petroleum products: petroleum products with a boiling range 15°C - 370°C Flash point TAG closed cup method Range ASTM D 56-22","technique_en":"TAG closed cup method","test_object_en":"Liquid fuels: aviation turbine fuel, Other petroleum products: petroleum products with a boiling range 15°C - 370°C","parameters_zh":[{"name":"范围","range":"(4,0 – 70,0) °C"}],"search_zh":"闪点 范围 ASTM D 56-22","methodology_zh":"闪点"},{"_id":"6a836fb9af14b9c0e7b1eb65","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych","methodology":"Przewodność właściwa","parameters":[{"name":"Zakres","range":"(1 – 800) pS/m"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność właściwa\nZakres (1 – 800) pS/m\nMetoda konduktometryczna","reference":"ASTM D 2624-24","norm_bases":["ASTM D 2624-24"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych Przewodność właściwa\nZakres (1 – 800) pS/m\nMetoda konduktometryczna ASTM D 2624-24 Paliwa ciekle: paliwo do turbinowych silnikow lotniczych Przewodnosc wlasciwa\nZakres (1 – 800) pS/m\nMetoda konduktometryczna ASTM D 2624-24","categories":["petro"],"row_index":78,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Specific conductivity","parameters_en":[{"name":"Range","range":"(1 – 800) pS/m"}],"search_en":"Liquid fuels: aviation turbine fuel Specific conductivity Conductometric method Range ASTM D 2624-24","technique_en":"Conductometric method","test_object_en":"Liquid fuels: aviation turbine fuel","parameters_zh":[{"name":"范围","range":"(1 – 800) pS/m"}],"search_zh":"液体燃料：航空涡轮发动机燃料 电导法 范围 ASTM D 2624-24","technique_zh":"电导法","test_object_zh":"液体燃料：航空涡轮发动机燃料"},{"_id":"6a836fb9af14b9c0e7b1eb66","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych, Inne przetwory naftowe: produkty naftowe o zakresie temperatur wrzenia 100°C - 350°C, destylaty naftowe","methodology":"Lepkość kinematyczna w temp. (-20) °C","parameters":[{"name":"Zakres","range":"(2,000 – 8,000) mm2/s"}],"technique":"Metoda kapilarna","techniques":["Metoda kapilarna"],"computed":[],"activity":"Lepkość kinematyczna w temp. (-20) °C\nZakres (2,000 – 8,000) mm2/s\nMetoda kapilarna","reference":"ASTM D 445-24","norm_bases":["ASTM D 445-24"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych, Inne przetwory naftowe: produkty naftowe o zakresie temperatur wrzenia 100°C - 350°C, destylaty naftowe Lepkość kinematyczna w temp. (-20) °C\nZakres (2,000 – 8,000) mm2/s\nMetoda kapilarna ASTM D 445-24 Paliwa ciekle: paliwo do turbinowych silnikow lotniczych, Inne przetwory naftowe: produkty naftowe o zakresie temperatur wrzenia 100°C - 350°C, destylaty naftowe Lepkosc kinematyczna w temp. (-20) °C\nZakres (2,000 – 8,000) mm2/s\nMetoda kapilarna ASTM D 445-24","categories":["petro"],"row_index":79,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kinematic viscosity at (-20) °C","parameters_en":[{"name":"Range","range":"(2,000 – 8,000) mm2/s"}],"search_en":"Liquid fuels: aviation turbine fuel, Other petroleum products: petroleum products with a boiling range 100°C - 350°C, petroleum distillates Kinematic viscosity at (-20) °C Capillary method Range ASTM D 445-24","technique_en":"Capillary method","test_object_en":"Liquid fuels: aviation turbine fuel, Other petroleum products: petroleum products with a boiling range 100°C - 350°C, petroleum distillates","parameters_zh":[{"name":"范围","range":"(2,000 – 8,000) mm2/s"}],"search_zh":"毛细管法 范围 ASTM D 445-24","technique_zh":"毛细管法"},{"_id":"6a836fb9af14b9c0e7b1eb67","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna lotnicza, paliwo do turbinowych silników lotniczych, Inne przetwory naftowe: produkty naftowe o zakresie temperatur wrzenia 15°C - 350°C","methodology":"Zawartość żywic","parameters":[{"name":"Zakres","range":"(1 – 10) mg/100ml"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość żywic\nZakres (1 – 10) mg/100ml\nMetoda wagowa","reference":"ASTM D 381-25","norm_bases":["ASTM D 381-25"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna lotnicza, paliwo do turbinowych silników lotniczych, Inne przetwory naftowe: produkty naftowe o zakresie temperatur wrzenia 15°C - 350°C Zawartość żywic\nZakres (1 – 10) mg/100ml\nMetoda wagowa ASTM D 381-25 Paliwa ciekle: benzyna lotnicza, paliwo do turbinowych silnikow lotniczych, Inne przetwory naftowe: produkty naftowe o zakresie temperatur wrzenia 15°C - 350°C Zawartosc zywic\nZakres (1 – 10) mg/100ml\nMetoda wagowa ASTM D 381-25","categories":["petro"],"row_index":80,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gum content","parameters_en":[{"name":"Range","range":"(1 – 10) mg/100ml"}],"search_en":"Liquid fuels: aviation gasoline, aviation turbine fuel, Other petroleum products: petroleum products with a boiling range 15°C - 350°C Gum content Gravimetric method Range ASTM D 381-25","technique_en":"Gravimetric method","test_object_en":"Liquid fuels: aviation gasoline, aviation turbine fuel, Other petroleum products: petroleum products with a boiling range 15°C - 350°C","parameters_zh":[{"name":"范围","range":"(1 – 10) mg/100ml"}],"search_zh":"树脂含量 重量法 范围 ASTM D 381-25","technique_zh":"重量法","methodology_zh":"树脂含量"},{"_id":"6a836fb9af14b9c0e7b1eb68","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych","methodology":"Reakcja paliwa z wodą i ocena powierzchni międzyfazowej","parameters":[],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Reakcja paliwa z wodą i ocena powierzchni międzyfazowej\nMetoda wizualna","reference":"ASTM D 1094-24","norm_bases":["ASTM D 1094-24"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych Reakcja paliwa z wodą i ocena powierzchni międzyfazowej\nMetoda wizualna ASTM D 1094-24 Paliwa ciekle: paliwo do turbinowych silnikow lotniczych Reakcja paliwa z woda i ocena powierzchni miedzyfazowej\nMetoda wizualna ASTM D 1094-24","categories":["petro"],"row_index":81,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Reaction of fuel with water and assessment of the interface","search_en":"Liquid fuels: aviation turbine fuel Reaction of fuel with water and assessment of the interface Visual method ASTM D 1094-24","technique_en":"Visual method","test_object_en":"Liquid fuels: aviation turbine fuel","search_zh":"液体燃料：航空涡轮发动机燃料 目视法 ASTM D 1094-24","technique_zh":"目视法","test_object_zh":"液体燃料：航空涡轮发动机燃料"},{"_id":"6a836fb9af14b9c0e7b1eb69","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych","methodology":"Temperatura krystalizacji","parameters":[{"name":"[(-75,0)","range":"(-42,0)] oC"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Temperatura krystalizacji\n[(-75,0) (-42,0)] oC\nMetoda optyczna","reference":"ASTM D 5972-25","norm_bases":["ASTM D 5972-25"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych Temperatura krystalizacji\n[(-75,0) (-42,0)] oC\nMetoda optyczna ASTM D 5972-25 Paliwa ciekle: paliwo do turbinowych silnikow lotniczych Temperatura krystalizacji\n[(-75,0) (-42,0)] oC\nMetoda optyczna ASTM D 5972-25","categories":["petro"],"row_index":82,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Crystallisation temperature","parameters_en":[{"name":"[(-75,0)","range":"(-42,0)] oC"}],"search_en":"Liquid fuels: aviation turbine fuel Crystallisation temperature Optical method [(-75,0) ASTM D 5972-25","technique_en":"Optical method","test_object_en":"Liquid fuels: aviation turbine fuel","search_zh":"液体燃料：航空涡轮发动机燃料 结晶温度 光学法 ASTM D 5972-25","technique_zh":"光学法","test_object_zh":"液体燃料：航空涡轮发动机燃料","methodology_zh":"结晶温度"},{"_id":"6a836fb9af14b9c0e7b1eb6a","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych","methodology":"Temperatura krystalizacji","parameters":[{"name":"[(-62,0)","range":"(-42,0)] oC"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Temperatura krystalizacji\n[(-62,0) (-42,0)] oC\nMetoda wizualna","reference":"ASTM D 2386-19","norm_bases":["ASTM D 2386-19"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych Temperatura krystalizacji\n[(-62,0) (-42,0)] oC\nMetoda wizualna ASTM D 2386-19 Paliwa ciekle: paliwo do turbinowych silnikow lotniczych Temperatura krystalizacji\n[(-62,0) (-42,0)] oC\nMetoda wizualna ASTM D 2386-19","categories":["petro"],"row_index":83,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Crystallisation temperature","parameters_en":[{"name":"[(-62,0)","range":"(-42,0)] oC"}],"search_en":"Liquid fuels: aviation turbine fuel Crystallisation temperature Visual method [(-62,0) ASTM D 2386-19","technique_en":"Visual method","test_object_en":"Liquid fuels: aviation turbine fuel","search_zh":"液体燃料：航空涡轮发动机燃料 结晶温度 目视法 ASTM D 2386-19","technique_zh":"目视法","test_object_zh":"液体燃料：航空涡轮发动机燃料","methodology_zh":"结晶温度"},{"_id":"6a836fb9af14b9c0e7b1eb6b","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych","methodology":"Zawartość siarki merkaptanowej","parameters":[{"name":"Zakres","range":"(0,0003 – 0,01) %(m/m)"}],"technique":"Metoda miareczkowania potencjometrycznego","techniques":["Metoda miareczkowania potencjometrycznego"],"computed":[],"activity":"Zawartość siarki merkaptanowej\nZakres (0,0003 – 0,01) %(m/m)\nMetoda miareczkowania potencjometrycznego","reference":"ASTM D 3227-24","norm_bases":["ASTM D 3227-24"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych Zawartość siarki merkaptanowej\nZakres (0,0003 – 0,01) %(m/m)\nMetoda miareczkowania potencjometrycznego ASTM D 3227-24 Paliwa ciekle: paliwo do turbinowych silnikow lotniczych Zawartosc siarki merkaptanowej\nZakres (0,0003 – 0,01) %(m/m)\nMetoda miareczkowania potencjometrycznego ASTM D 3227-24","categories":["petro"],"row_index":84,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercaptan sulphur content","parameters_en":[{"name":"Range","range":"(0,0003 – 0,01) %(m/m)"}],"search_en":"Liquid fuels: aviation turbine fuel Mercaptan sulphur content Potentiometric titration method Range ASTM D 3227-24","technique_en":"Potentiometric titration method","test_object_en":"Liquid fuels: aviation turbine fuel","parameters_zh":[{"name":"范围","range":"(0,0003 – 0,01) %(m/m)"}],"search_zh":"液体燃料：航空涡轮发动机燃料 电位滴定法 范围 ASTM D 3227-24","technique_zh":"电位滴定法","test_object_zh":"液体燃料：航空涡轮发动机燃料"},{"_id":"6a836fb9af14b9c0e7b1eb6c","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych, paliwo do turbinowych silników lotniczych zawierające dodatki do paliw","methodology":"Właściwości separacyjne wody","parameters":[{"name":"Zakres","range":"70 – 100"}],"technique":"Metoda turbidymetryczna","techniques":["Metoda turbidymetryczna"],"computed":[],"activity":"Właściwości separacyjne wody\nZakres 70 – 100\nMetoda turbidymetryczna","reference":"ASTM D 7224-23","norm_bases":["ASTM D 7224-23"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych, paliwo do turbinowych silników lotniczych zawierające dodatki do paliw Właściwości separacyjne wody\nZakres 70 – 100\nMetoda turbidymetryczna ASTM D 7224-23 Paliwa ciekle: paliwo do turbinowych silnikow lotniczych, paliwo do turbinowych silnikow lotniczych zawierajace dodatki do paliw Wlasciwosci separacyjne wody\nZakres 70 – 100\nMetoda turbidymetryczna ASTM D 7224-23","categories":["petro","water"],"row_index":85,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water separation properties","parameters_en":[{"name":"Range","range":"70 – 100"}],"search_en":"Liquid fuels: aviation turbine fuel, aviation turbine fuel containing fuel additives Water separation properties Turbidimetric method Range ASTM D 7224-23","technique_en":"Turbidimetric method","test_object_en":"Liquid fuels: aviation turbine fuel, aviation turbine fuel containing fuel additives","parameters_zh":[{"name":"范围","range":"70 – 100"}],"search_zh":"浊度法 范围 ASTM D 7224-23","technique_zh":"浊度法"},{"_id":"6a836fb9af14b9c0e7b1eb6d","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych","methodology":"Zawartość węglowodorów aromatycznych","parameters":[{"name":"MAH","range":"(10,0 – 25,0) %(m/m)"},{"name":"MAH","range":"(10,0 – 25,0) %(v/v)"},{"name":"DAH","range":"(0,1 – 7,0) %(m/m)"},{"name":"DAH","range":"(0,1 – 6,5) %(v/v)"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją refraktometryczną (HPLC-RID)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją refraktometryczną (HPLC-RID)"],"computed":[],"activity":"Zawartość węglowodorów aromatycznych\nZakres:\nMAH (10,0 – 25,0) %(m/m)\nMAH (10,0 – 25,0) %(v/v)\nDAH (0,1 – 7,0) %(m/m)\nDAH (0,1 – 6,5) %(v/v)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją refraktometryczną (HPLC-RID)","reference":"ASTM D 6379-21e1","norm_bases":["ASTM D 6379-21e1"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych Zawartość węglowodorów aromatycznych\nZakres:\nMAH (10,0 – 25,0) %(m/m)\nMAH (10,0 – 25,0) %(v/v)\nDAH (0,1 – 7,0) %(m/m)\nDAH (0,1 – 6,5) %(v/v)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją refraktometryczną (HPLC-RID) ASTM D 6379-21e1 Paliwa ciekle: paliwo do turbinowych silnikow lotniczych Zawartosc weglowodorow aromatycznych\nZakres:\nMAH (10,0 – 25,0) %(m/m)\nMAH (10,0 – 25,0) %(v/v)\nDAH (0,1 – 7,0) %(m/m)\nDAH (0,1 – 6,5) %(v/v)\nMetoda wysokosprawnej chromatografii cieczowej z detekcja refraktometryczna (HPLC-RID) ASTM D 6379-21e1","categories":["petro"],"row_index":86,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Aromatic hydrocarbon content","parameters_en":[{"name":"MAH","range":"(10,0 – 25,0) %(m/m)"},{"name":"MAH","range":"(10,0 – 25,0) %(v/v)"},{"name":"DAH","range":"(0,1 – 7,0) %(m/m)"},{"name":"DAH","range":"(0,1 – 6,5) %(v/v)"}],"search_en":"Liquid fuels: aviation turbine fuel Aromatic hydrocarbon content High-performance liquid chromatography with refractive index detection (HPLC-RID) MAH MAH DAH DAH ASTM D 6379-21e1","technique_en":"High-performance liquid chromatography with refractive index detection (HPLC-RID)","test_object_en":"Liquid fuels: aviation turbine fuel","search_zh":"液体燃料：航空涡轮发动机燃料 芳香烃含量 高效液相色谱-示差折光检测法（HPLC-RID） ASTM D 6379-21e1","technique_zh":"高效液相色谱-示差折光检测法（HPLC-RID）","test_object_zh":"液体燃料：航空涡轮发动机燃料","methodology_zh":"芳香烃含量"},{"_id":"6a836fb9af14b9c0e7b1eb6e","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych","methodology":"Suma węglowodorów aromatycznych (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma węglowodorów aromatycznych (z obliczeń)","reference":"ASTM D 6379-21e1","norm_bases":["ASTM D 6379-21e1"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych Suma węglowodorów aromatycznych (z obliczeń) ASTM D 6379-21e1 Paliwa ciekle: paliwo do turbinowych silnikow lotniczych Suma weglowodorow aromatycznych (z obliczen) ASTM D 6379-21e1","categories":["petro"],"row_index":87,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of aromatic hydrocarbons (calculated)","search_en":"Liquid fuels: aviation turbine fuel Sum of aromatic hydrocarbons (calculated) ASTM D 6379-21e1","test_object_en":"Liquid fuels: aviation turbine fuel","search_zh":"液体燃料：航空涡轮发动机燃料 芳香烃总量（由计算得出） ASTM D 6379-21e1","test_object_zh":"液体燃料：航空涡轮发动机燃料","methodology_zh":"芳香烃总量（由计算得出）"},{"_id":"6a836fb9af14b9c0e7b1eb6f","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych, Inne przetwory naftowe: produkty naftowe o zakresie temperatur wrzenia 15°C - 350°C","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(+10) – (+30) wg skali Saybolt"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Barwa\nZakres (+10) – (+30) wg skali Saybolt\nMetoda wizualna","reference":"ASTM D 156-23","norm_bases":["ASTM D 156-23"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych, Inne przetwory naftowe: produkty naftowe o zakresie temperatur wrzenia 15°C - 350°C Barwa\nZakres (+10) – (+30) wg skali Saybolt\nMetoda wizualna ASTM D 156-23 Paliwa ciekle: paliwo do turbinowych silnikow lotniczych, Inne przetwory naftowe: produkty naftowe o zakresie temperatur wrzenia 15°C - 350°C Barwa\nZakres (+10) – (+30) wg skali Saybolt\nMetoda wizualna ASTM D 156-23","categories":["petro"],"row_index":88,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"(+10) – (+30) wg skali Saybolt"}],"search_en":"Liquid fuels: aviation turbine fuel, Other petroleum products: petroleum products with a boiling range 15°C - 350°C Colour Visual method Range ASTM D 156-23","technique_en":"Visual method","test_object_en":"Liquid fuels: aviation turbine fuel, Other petroleum products: petroleum products with a boiling range 15°C - 350°C","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(+10) – (+30) wg skali Saybolt"}],"search_zh":"色度 目视法 范围 ASTM D 156-23","technique_zh":"目视法"},{"_id":"6a836fb9af14b9c0e7b1eb70","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych","methodology":"Zawartość cząstek stałych","parameters":[{"name":"Zakres","range":"(0,0 – 10,0) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość cząstek stałych\nZakres (0,0 – 10,0) mg/l\nMetoda wagowa","reference":"ASTM D 5452-23 | PN-V-04031:2000","norm_bases":["ASTM D 5452-23","PN-V-04031:2000"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych Zawartość cząstek stałych\nZakres (0,0 – 10,0) mg/l\nMetoda wagowa ASTM D 5452-23 | PN-V-04031:2000 Paliwa ciekle: paliwo do turbinowych silnikow lotniczych Zawartosc czastek stalych\nZakres (0,0 – 10,0) mg/l\nMetoda wagowa ASTM D 5452-23 | PN-V-04031:2000","categories":["petro"],"row_index":89,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Particulate matter content","parameters_en":[{"name":"Range","range":"(0,0 – 10,0) mg/l"}],"search_en":"Liquid fuels: aviation turbine fuel Particulate matter content Gravimetric method Range ASTM D 5452-23 | PN-V-04031:2000","technique_en":"Gravimetric method","test_object_en":"Liquid fuels: aviation turbine fuel","parameters_zh":[{"name":"范围","range":"(0,0 – 10,0) mg/l"}],"search_zh":"液体燃料：航空涡轮发动机燃料 重量法 范围 ASTM D 5452-23 | PN-V-04031:2000","technique_zh":"重量法","test_object_zh":"液体燃料：航空涡轮发动机燃料"},{"_id":"6a836fb9af14b9c0e7b1eb71","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych","methodology":"Zawartość żywic obecnych","parameters":[{"name":"Zakres","range":"(1 – 10) mg/100ml"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość żywic obecnych\nZakres (1 – 10) mg/100ml\nMetoda wagowa","reference":"IP 540/08(2019)","norm_bases":["IP 540/08(2019)"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych Zawartość żywic obecnych\nZakres (1 – 10) mg/100ml\nMetoda wagowa IP 540/08(2019) Paliwa ciekle: paliwo do turbinowych silnikow lotniczych Zawartosc zywic obecnych\nZakres (1 – 10) mg/100ml\nMetoda wagowa IP 540/08(2019)","categories":["petro"],"row_index":90,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Existent gum content","parameters_en":[{"name":"Range","range":"(1 – 10) mg/100ml"}],"search_en":"Liquid fuels: aviation turbine fuel Existent gum content Gravimetric method Range IP 540/08(2019)","technique_en":"Gravimetric method","test_object_en":"Liquid fuels: aviation turbine fuel","parameters_zh":[{"name":"范围","range":"(1 – 10) mg/100ml"}],"search_zh":"液体燃料：航空涡轮发动机燃料 实际胶质含量 重量法 范围 IP 540/08(2019)","technique_zh":"重量法","test_object_zh":"液体燃料：航空涡轮发动机燃料","methodology_zh":"实际胶质含量"},{"_id":"6a836fb9af14b9c0e7b1eb72","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych","methodology":"Zawartość węglowodorów naftalenowych","parameters":[{"name":"Zakres","range":"(0,08 – 2,0) %(v/v)"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość węglowodorów naftalenowych\nZakres (0,08 – 2,0) %(v/v)\nMetoda spektrofotometryczna","reference":"ASTM D 1840-24","norm_bases":["ASTM D 1840-24"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych Zawartość węglowodorów naftalenowych\nZakres (0,08 – 2,0) %(v/v)\nMetoda spektrofotometryczna ASTM D 1840-24 Paliwa ciekle: paliwo do turbinowych silnikow lotniczych Zawartosc weglowodorow naftalenowych\nZakres (0,08 – 2,0) %(v/v)\nMetoda spektrofotometryczna ASTM D 1840-24","categories":["petro"],"row_index":91,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of naphthalene hydrocarbons","parameters_en":[{"name":"Range","range":"(0,08 – 2,0) %(v/v)"}],"search_en":"Liquid fuels: aviation turbine fuel Content of naphthalene hydrocarbons Spectrophotometric method Range ASTM D 1840-24","technique_en":"Spectrophotometric method","test_object_en":"Liquid fuels: aviation turbine fuel","parameters_zh":[{"name":"范围","range":"(0,08 – 2,0) %(v/v)"}],"search_zh":"液体燃料：航空涡轮发动机燃料 分光光度法 范围 ASTM D 1840-24","technique_zh":"分光光度法","test_object_zh":"液体燃料：航空涡轮发动机燃料"},{"_id":"6a836fb9af14b9c0e7b1eb73","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Inne przetwory naftowe: produkty naftowe o zakresie temperatur wrzenia 30°C - 380°C","methodology":"Liczba bromowa","parameters":[{"name":"Zakres","range":"(0,1 – 100) g/100 g próbki"}],"technique":"Metoda miareczkowania potencjometrycznego","techniques":["Metoda miareczkowania potencjometrycznego"],"computed":[],"activity":"Liczba bromowa\nZakres (0,1 – 100) g/100 g próbki\nMetoda miareczkowania potencjometrycznego","reference":"ASTM D 1159-23","norm_bases":["ASTM D 1159-23"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Inne przetwory naftowe: produkty naftowe o zakresie temperatur wrzenia 30°C - 380°C Liczba bromowa\nZakres (0,1 – 100) g/100 g próbki\nMetoda miareczkowania potencjometrycznego ASTM D 1159-23 Inne przetwory naftowe: produkty naftowe o zakresie temperatur wrzenia 30°C - 380°C Liczba bromowa\nZakres (0,1 – 100) g/100 g probki\nMetoda miareczkowania potencjometrycznego ASTM D 1159-23","categories":["other"],"row_index":92,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Bromine number","parameters_en":[{"name":"Range","range":"(0,1 – 100) g/100 g próbki"}],"search_en":"Other petroleum products: petroleum products with a boiling range 30°C - 380°C Bromine number Potentiometric titration method Range ASTM D 1159-23","technique_en":"Potentiometric titration method","test_object_en":"Other petroleum products: petroleum products with a boiling range 30°C - 380°C","parameters_zh":[{"name":"范围","range":"(0,1 – 100) g/100 g próbki"}],"search_zh":"电位滴定法 范围 ASTM D 1159-23","technique_zh":"电位滴定法"},{"_id":"6a836fb9af14b9c0e7b1eb74","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Inne przetwory naftowe: produkty naftowe o zakresie temperatur wrzenia 30°C - 250°C, Wyroby chemiczne: węglowodory aromatyczne","methodology":"Barwa wyciągu kwaśnego","parameters":[{"name":"Zakres","range":"0 – 14"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Barwa wyciągu kwaśnego\nZakres 0 – 14\nMetoda wizualna","reference":"ASTM D 848-23","norm_bases":["ASTM D 848-23"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Inne przetwory naftowe: produkty naftowe o zakresie temperatur wrzenia 30°C - 250°C, Wyroby chemiczne: węglowodory aromatyczne Barwa wyciągu kwaśnego\nZakres 0 – 14\nMetoda wizualna ASTM D 848-23 Inne przetwory naftowe: produkty naftowe o zakresie temperatur wrzenia 30°C - 250°C, Wyroby chemiczne: weglowodory aromatyczne Barwa wyciagu kwasnego\nZakres 0 – 14\nMetoda wizualna ASTM D 848-23","categories":["other"],"row_index":93,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Colour of the acid extract","parameters_en":[{"name":"Range","range":"0 – 14"}],"search_en":"Other petroleum products: petroleum products with a boiling range of 30°C - 250°C, Chemical products: aromatic hydrocarbons Colour of the acid extract Visual method Range ASTM D 848-23","technique_en":"Visual method","test_object_en":"Other petroleum products: petroleum products with a boiling range of 30°C - 250°C, Chemical products: aromatic hydrocarbons","parameters_zh":[{"name":"范围","range":"0 – 14"}],"search_zh":"其他石油加工品：沸程 30°C - 250°C 的石油产品；化工产品：芳香烃 目视法 范围 ASTM D 848-23","technique_zh":"目视法","test_object_zh":"其他石油加工品：沸程 30°C - 250°C 的石油产品；化工产品：芳香烃"},{"_id":"6a836fb9af14b9c0e7b1eb75","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Inne przetwory naftowe: produkty naftowe o zakresie temperatur wrzenia 30°C - 250°C, Wyroby chemiczne: węglowodory aromatyczne","methodology":"Barwa","parameters":[{"name":"Zakres","range":"1 – 10"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Barwa\nZakres 1 – 10\nMetoda wizualna","reference":"ASTM D 1209-25","norm_bases":["ASTM D 1209-25"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Inne przetwory naftowe: produkty naftowe o zakresie temperatur wrzenia 30°C - 250°C, Wyroby chemiczne: węglowodory aromatyczne Barwa\nZakres 1 – 10\nMetoda wizualna ASTM D 1209-25 Inne przetwory naftowe: produkty naftowe o zakresie temperatur wrzenia 30°C - 250°C, Wyroby chemiczne: weglowodory aromatyczne Barwa\nZakres 1 – 10\nMetoda wizualna ASTM D 1209-25","categories":["other"],"row_index":94,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"1 – 10"}],"search_en":"Other petroleum products: petroleum products with a boiling range of 30°C - 250°C, Chemical products: aromatic hydrocarbons Colour Visual method Range ASTM D 1209-25","technique_en":"Visual method","test_object_en":"Other petroleum products: petroleum products with a boiling range of 30°C - 250°C, Chemical products: aromatic hydrocarbons","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"1 – 10"}],"search_zh":"其他石油加工品：沸程 30°C - 250°C 的石油产品；化工产品：芳香烃 色度 目视法 范围 ASTM D 1209-25","technique_zh":"目视法","test_object_zh":"其他石油加工品：沸程 30°C - 250°C 的石油产品；化工产品：芳香烃"},{"_id":"6a836fb9af14b9c0e7b1eb76","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Inne przetwory naftowe: produkty naftowe o zakresie temperatur wrzenia 30°C - 250°C, Wyroby chemiczne: węglowodory aromatyczne","methodology":"Kwasowość","parameters":[],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Kwasowość\nMetoda wizualna","reference":"ASTM D 847-23","norm_bases":["ASTM D 847-23"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Inne przetwory naftowe: produkty naftowe o zakresie temperatur wrzenia 30°C - 250°C, Wyroby chemiczne: węglowodory aromatyczne Kwasowość\nMetoda wizualna ASTM D 847-23 Inne przetwory naftowe: produkty naftowe o zakresie temperatur wrzenia 30°C - 250°C, Wyroby chemiczne: weglowodory aromatyczne Kwasowosc\nMetoda wizualna ASTM D 847-23","categories":["other"],"row_index":95,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Acidity","search_en":"Other petroleum products: petroleum products with a boiling range of 30°C - 250°C, Chemical products: aromatic hydrocarbons Acidity Visual method ASTM D 847-23","technique_en":"Visual method","test_object_en":"Other petroleum products: petroleum products with a boiling range of 30°C - 250°C, Chemical products: aromatic hydrocarbons","methodology_zh":"酸度","search_zh":"其他石油加工品：沸程 30°C - 250°C 的石油产品；化工产品：芳香烃 酸度 目视法 ASTM D 847-23","technique_zh":"目视法","test_object_zh":"其他石油加工品：沸程 30°C - 250°C 的石油产品；化工产品：芳香烃"},{"_id":"6a836fb9af14b9c0e7b1eb77","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Inne przetwory naftowe: produkty naftowe o zakresie temperatur wrzenia 30°C - 250°C, Wyroby chemiczne: węglowodory aromatyczne","methodology":"Zawartość tiofenu","parameters":[{"name":"Zakres","range":"(0,14 – 2,61) mg/kg"}],"technique":"Metoda chromatografii gazowej z pulsacyjną detekcją płomieniowo-fotometryczną (GC-PFPD)","techniques":["Metoda chromatografii gazowej z pulsacyjną detekcją płomieniowo-fotometryczną (GC-PFPD)"],"computed":[],"activity":"Zawartość tiofenu\nZakres (0,14 – 2,61) mg/kg\nMetoda chromatografii gazowej z pulsacyjną detekcją płomieniowo-fotometryczną (GC-PFPD)","reference":"ASTM D 4735-19","norm_bases":["ASTM D 4735-19"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Inne przetwory naftowe: produkty naftowe o zakresie temperatur wrzenia 30°C - 250°C, Wyroby chemiczne: węglowodory aromatyczne Zawartość tiofenu\nZakres (0,14 – 2,61) mg/kg\nMetoda chromatografii gazowej z pulsacyjną detekcją płomieniowo-fotometryczną (GC-PFPD) ASTM D 4735-19 Inne przetwory naftowe: produkty naftowe o zakresie temperatur wrzenia 30°C - 250°C, Wyroby chemiczne: weglowodory aromatyczne Zawartosc tiofenu\nZakres (0,14 – 2,61) mg/kg\nMetoda chromatografii gazowej z pulsacyjna detekcja plomieniowo-fotometryczna (GC-PFPD) ASTM D 4735-19","categories":["other"],"row_index":96,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Thiophene content","parameters_en":[{"name":"Range","range":"(0,14 – 2,61) mg/kg"}],"search_en":"Other petroleum products: petroleum products with a boiling range of 30°C - 250°C, Chemical products: aromatic hydrocarbons Thiophene content Range ASTM D 4735-19","test_object_en":"Other petroleum products: petroleum products with a boiling range of 30°C - 250°C, Chemical products: aromatic hydrocarbons","parameters_zh":[{"name":"范围","range":"(0,14 – 2,61) mg/kg"}],"search_zh":"其他石油加工品：沸程 30°C - 250°C 的石油产品；化工产品：芳香烃 范围 ASTM D 4735-19","test_object_zh":"其他石油加工品：沸程 30°C - 250°C 的石油产品；化工产品：芳香烃"},{"_id":"6a836fb9af14b9c0e7b1eb78","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Inne przetwory naftowe: frakcje i/ lub produkty naftowe o zakresie temperatur wrzenia 30°C - 400°C, Wyroby chemiczne: węglowodory aromatyczne","methodology":"Zawartość chlorków","parameters":[{"name":"Zakres","range":"(0,3 – 10,0) mg/kg"}],"technique":"Metoda mikrokulometryczna","techniques":["Metoda mikrokulometryczna"],"computed":[],"activity":"Zawartość chlorków\nZakres (0,3 – 10,0) mg/kg\nMetoda mikrokulometryczna","reference":"UOP 779-08","norm_bases":["UOP 779-08"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Inne przetwory naftowe: frakcje i/ lub produkty naftowe o zakresie temperatur wrzenia 30°C - 400°C, Wyroby chemiczne: węglowodory aromatyczne Zawartość chlorków\nZakres (0,3 – 10,0) mg/kg\nMetoda mikrokulometryczna UOP 779-08 Inne przetwory naftowe: frakcje i/ lub produkty naftowe o zakresie temperatur wrzenia 30°C - 400°C, Wyroby chemiczne: weglowodory aromatyczne Zawartosc chlorkow\nZakres (0,3 – 10,0) mg/kg\nMetoda mikrokulometryczna UOP 779-08","categories":["other"],"row_index":97,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride content","parameters_en":[{"name":"Range","range":"(0,3 – 10,0) mg/kg"}],"search_en":"Other petroleum products: petroleum fractions and/ or products with a boiling range 30°C - 400°C, Chemical products: aromatic hydrocarbons Chloride content Microcoulometric method Range UOP 779-08","technique_en":"Microcoulometric method","test_object_en":"Other petroleum products: petroleum fractions and/ or products with a boiling range 30°C - 400°C, Chemical products: aromatic hydrocarbons","parameters_zh":[{"name":"范围","range":"(0,3 – 10,0) mg/kg"}],"search_zh":"氯化物含量 微库仑法 范围 UOP 779-08","methodology_zh":"氯化物含量","technique_zh":"微库仑法"},{"_id":"6a836fb9af14b9c0e7b1eb79","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Wyroby chemiczne: węglowodory aromatyczne, frakcje węglowodorów aromatycznych, Inne przetwory naftowe: lekkie komponenty benzynowe","methodology":"Całkowita zawartość siarki","parameters":[{"name":"Zakres","range":"(0,10 – 10,0) mg/kg"}],"technique":"Metoda fluorescencji w nadfiolecie","techniques":["Metoda fluorescencji w nadfiolecie"],"computed":[],"activity":"Całkowita zawartość siarki\nZakres (0,10 – 10,0) mg/kg\nMetoda fluorescencji w nadfiolecie","reference":"ASTM D 7183-23","norm_bases":["ASTM D 7183-23"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby chemiczne: węglowodory aromatyczne, frakcje węglowodorów aromatycznych, Inne przetwory naftowe: lekkie komponenty benzynowe Całkowita zawartość siarki\nZakres (0,10 – 10,0) mg/kg\nMetoda fluorescencji w nadfiolecie ASTM D 7183-23 Wyroby chemiczne: weglowodory aromatyczne, frakcje weglowodorow aromatycznych, Inne przetwory naftowe: lekkie komponenty benzynowe Calkowita zawartosc siarki\nZakres (0,10 – 10,0) mg/kg\nMetoda fluorescencji w nadfiolecie ASTM D 7183-23","categories":["other"],"row_index":98,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total sulphur content","parameters_en":[{"name":"Range","range":"(0,10 – 10,0) mg/kg"}],"search_en":"Chemical products: aromatic hydrocarbons, aromatic hydrocarbon fractions, Other petroleum products: light gasoline components Total sulphur content Ultraviolet fluorescence method Range ASTM D 7183-23","technique_en":"Ultraviolet fluorescence method","test_object_en":"Chemical products: aromatic hydrocarbons, aromatic hydrocarbon fractions, Other petroleum products: light gasoline components","parameters_zh":[{"name":"范围","range":"(0,10 – 10,0) mg/kg"}],"search_zh":"紫外荧光法 范围 ASTM D 7183-23","technique_zh":"紫外荧光法"},{"_id":"6a836fb9af14b9c0e7b1eb7a","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Wyroby chemiczne: węglowodory aromatyczne","methodology":"Skład frakcyjny wraz z suchym punktem","parameters":[{"name":"Zakres","range":"(70,0 – 145,0) °C"}],"technique":"Metoda destylacyjna","techniques":["Metoda destylacyjna"],"computed":[],"activity":"Skład frakcyjny wraz z suchym punktem\nZakres (70,0 – 145,0) °C\nMetoda destylacyjna","reference":"ASTM D 850-21","norm_bases":["ASTM D 850-21"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby chemiczne: węglowodory aromatyczne Skład frakcyjny wraz z suchym punktem\nZakres (70,0 – 145,0) °C\nMetoda destylacyjna ASTM D 850-21 Wyroby chemiczne: weglowodory aromatyczne Sklad frakcyjny wraz z suchym punktem\nZakres (70,0 – 145,0) °C\nMetoda destylacyjna ASTM D 850-21","categories":["other"],"row_index":99,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Distillation characteristics including the dry point","parameters_en":[{"name":"Range","range":"(70,0 – 145,0) °C"}],"search_en":"Chemical products: aromatic hydrocarbons Distillation characteristics including the dry point Distillation method Range ASTM D 850-21","technique_en":"Distillation method","test_object_en":"Chemical products: aromatic hydrocarbons","parameters_zh":[{"name":"范围","range":"(70,0 – 145,0) °C"}],"search_zh":"化工产品：芳香烃 蒸馏法 范围 ASTM D 850-21","technique_zh":"蒸馏法","test_object_zh":"化工产品：芳香烃"},{"_id":"6a836fb9af14b9c0e7b1eb7b","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Wyroby chemiczne: węglowodory aromatyczne","methodology":"Zawartość chlorków","parameters":[{"name":"Zakres","range":"(1,0 – 25,0) mg/kg"}],"technique":"Metoda mikrokulometryczna","techniques":["Metoda mikrokulometryczna"],"computed":[],"activity":"Zawartość chlorków\nZakres (1,0 – 25,0) mg/kg\nMetoda mikrokulometryczna","reference":"ASTM D 5808-23","norm_bases":["ASTM D 5808-23"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby chemiczne: węglowodory aromatyczne Zawartość chlorków\nZakres (1,0 – 25,0) mg/kg\nMetoda mikrokulometryczna ASTM D 5808-23 Wyroby chemiczne: weglowodory aromatyczne Zawartosc chlorkow\nZakres (1,0 – 25,0) mg/kg\nMetoda mikrokulometryczna ASTM D 5808-23","categories":["other"],"row_index":100,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride content","parameters_en":[{"name":"Range","range":"(1,0 – 25,0) mg/kg"}],"search_en":"Chemical products: aromatic hydrocarbons Chloride content Microcoulometric method Range ASTM D 5808-23","technique_en":"Microcoulometric method","test_object_en":"Chemical products: aromatic hydrocarbons","parameters_zh":[{"name":"范围","range":"(1,0 – 25,0) mg/kg"}],"search_zh":"化工产品：芳香烃 氯化物含量 微库仑法 范围 ASTM D 5808-23","methodology_zh":"氯化物含量","technique_zh":"微库仑法","test_object_zh":"化工产品：芳香烃"},{"_id":"6a836fb9af14b9c0e7b1eb7c","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Wyroby chemiczne: węglowodory aromatyczne","methodology":"Temperatura krzepnięcia benzenu","parameters":[{"name":"Zakres","range":"(5,10 – 5,50) °C"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Temperatura krzepnięcia benzenu\nZakres (5,10 – 5,50) °C\nMetoda wizualna","reference":"ASTM D 852-24","norm_bases":["ASTM D 852-24"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby chemiczne: węglowodory aromatyczne Temperatura krzepnięcia benzenu\nZakres (5,10 – 5,50) °C\nMetoda wizualna ASTM D 852-24 Wyroby chemiczne: weglowodory aromatyczne Temperatura krzepniecia benzenu\nZakres (5,10 – 5,50) °C\nMetoda wizualna ASTM D 852-24","categories":["other"],"row_index":101,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Freezing point of benzene","parameters_en":[{"name":"Range","range":"(5,10 – 5,50) °C"}],"search_en":"Chemical products: aromatic hydrocarbons Freezing point of benzene Visual method Range ASTM D 852-24","technique_en":"Visual method","test_object_en":"Chemical products: aromatic hydrocarbons","parameters_zh":[{"name":"范围","range":"(5,10 – 5,50) °C"}],"search_zh":"化工产品：芳香烃 目视法 范围 ASTM D 852-24","technique_zh":"目视法","test_object_zh":"化工产品：芳香烃"},{"_id":"6a836fb9af14b9c0e7b1eb7d","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Wyroby chemiczne: węglowodory aromatyczne","methodology":"Zawartość azotu","parameters":[{"name":"Zakres","range":"(0,10 – 1,20) mg/kg"}],"technique":"Metoda chemiluminescencyjna","techniques":["Metoda chemiluminescencyjna"],"computed":[],"activity":"Zawartość azotu\nZakres (0,10 – 1,20) mg/kg\nMetoda chemiluminescencyjna","reference":"ASTM D 7184-24","norm_bases":["ASTM D 7184-24"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby chemiczne: węglowodory aromatyczne Zawartość azotu\nZakres (0,10 – 1,20) mg/kg\nMetoda chemiluminescencyjna ASTM D 7184-24 Wyroby chemiczne: weglowodory aromatyczne Zawartosc azotu\nZakres (0,10 – 1,20) mg/kg\nMetoda chemiluminescencyjna ASTM D 7184-24","categories":["other"],"row_index":102,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrogen content","parameters_en":[{"name":"Range","range":"(0,10 – 1,20) mg/kg"}],"search_en":"Chemical products: aromatic hydrocarbons Nitrogen content Chemiluminescence method Range ASTM D 7184-24","technique_en":"Chemiluminescence method","test_object_en":"Chemical products: aromatic hydrocarbons","methodology_zh":"氮含量","parameters_zh":[{"name":"范围","range":"(0,10 – 1,20) mg/kg"}],"search_zh":"化工产品：芳香烃 氮含量 化学发光法 范围 ASTM D 7184-24","technique_zh":"化学发光法","test_object_zh":"化工产品：芳香烃"},{"_id":"6a836fb9af14b9c0e7b1eb7e","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Wyroby chemiczne: węglowodory aromatyczne","methodology":"Indeks bromowy","parameters":[{"name":"Zakres","range":"(1,0 – 100,0) (mg Br/100g)"}],"technique":"Metoda miareczkowania kulometrycznego","techniques":["Metoda miareczkowania kulometrycznego"],"computed":[],"activity":"Indeks bromowy\nZakres (1,0 – 100,0) (mg Br/100g)\nMetoda miareczkowania kulometrycznego","reference":"ASTM D 1492-21","norm_bases":["ASTM D 1492-21"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby chemiczne: węglowodory aromatyczne Indeks bromowy\nZakres (1,0 – 100,0) (mg Br/100g)\nMetoda miareczkowania kulometrycznego ASTM D 1492-21 Wyroby chemiczne: weglowodory aromatyczne Indeks bromowy\nZakres (1,0 – 100,0) (mg Br/100g)\nMetoda miareczkowania kulometrycznego ASTM D 1492-21","categories":["other"],"row_index":103,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Bromine index","parameters_en":[{"name":"Range","range":"(1,0 – 100,0) (mg Br/100g)"}],"search_en":"Chemical products: aromatic hydrocarbons Bromine index Coulometric titration method Range ASTM D 1492-21","technique_en":"Coulometric titration method","test_object_en":"Chemical products: aromatic hydrocarbons","parameters_zh":[{"name":"范围","range":"(1,0 – 100,0) (mg Br/100g)"}],"search_zh":"化工产品：芳香烃 库仑滴定法 范围 ASTM D 1492-21","technique_zh":"库仑滴定法","test_object_zh":"化工产品：芳香烃"},{"_id":"6a836fb9af14b9c0e7b1eb7f","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Wyroby chemiczne: jednopierścieniowe węglowodory aromatyczne","methodology":"Zawartość śladowych zanieczyszczeń w jednopierścieniowych węglowodorach aromatycznych Całkowita zawartość zanieczyszczeń alifatycznych (C4 – C10) i poszczególnych jednopierścieniowych aromatycznych (C6 – C10)","parameters":[{"name":"Zakres","range":"(0,0006 – 2,5) %(m/m)"},{"name":"Czystość jednopierścieniowych węglowodorów aromatycznych"},{"name":"benzenu"},{"name":"toluenu"},{"name":"paraksylenu"},{"name":"Zakres","range":"97,60 – 99,99 %(m/m)"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość śladowych zanieczyszczeń w jednopierścieniowych węglowodorach aromatycznych Całkowita zawartość zanieczyszczeń alifatycznych (C4 – C10) i poszczególnych jednopierścieniowych aromatycznych (C6 – C10)\nZakres:\nZakres (0,0006 – 2,5) %(m/m)\nCzystość jednopierścieniowych węglowodorów aromatycznych\nbenzenu\ntoluenu\nparaksylenu\nZakres 97,60 – 99,99 %(m/m)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"ASTM D 7504-23","norm_bases":["ASTM D 7504-23"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby chemiczne: jednopierścieniowe węglowodory aromatyczne Zawartość śladowych zanieczyszczeń w jednopierścieniowych węglowodorach aromatycznych Całkowita zawartość zanieczyszczeń alifatycznych (C4 – C10) i poszczególnych jednopierścieniowych aromatycznych (C6 – C10)\nZakres:\nZakres (0,0006 – 2,5) %(m/m)\nCzystość jednopierścieniowych węglowodorów aromatycznych\nbenzenu\ntoluenu\nparaksylenu\nZakres 97,60 – 99,99 %(m/m)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) ASTM D 7504-23 Wyroby chemiczne: jednopierscieniowe weglowodory aromatyczne Zawartosc sladowych zanieczyszczen w jednopierscieniowych weglowodorach aromatycznych Calkowita zawartosc zanieczyszczen alifatycznych (C4 – C10) i poszczegolnych jednopierscieniowych aromatycznych (C6 – C10)\nZakres:\nZakres (0,0006 – 2,5) %(m/m)\nCzystosc jednopierscieniowych weglowodorow aromatycznych\nbenzenu\ntoluenu\nparaksylenu\nZakres 97,60 – 99,99 %(m/m)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) ASTM D 7504-23","categories":["other"],"row_index":104,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of trace impurities in monocyclic aromatic hydrocarbons Total content of aliphatic impurities (C4 – C10) and individual monocyclic aromatic impurities (C6 – C10)","parameters_en":[{"name":"Range","range":"(0,0006 – 2,5) %(m/m)"},{"name":"Purity of mononuclear aromatic hydrocarbons"},{"name":"benzene"},{"name":"toluene"},{"name":"para-xylene"},{"name":"Range","range":"97,60 – 99,99 %(m/m)"}],"search_en":"Chemical products: monocyclic aromatic hydrocarbons Content of trace impurities in monocyclic aromatic hydrocarbons Total content of aliphatic impurities (C4 – C10) and individual monocyclic aromatic impurities (C6 – C10) Gas chromatography with flame ionization detection (GC-FID) Range Purity of mononuclear aromatic hydrocarbons benzene toluene para-xylene Range ASTM D 7504-23","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Chemical products: monocyclic aromatic hydrocarbons","parameters_zh":[{"name":"范围","range":"(0,0006 – 2,5) %(m/m)"},{"name":"Czystość jednopierścieniowych węglowodorów aromatycznych"},{"name":"苯"},{"name":"甲苯"},{"name":"paraksylenu"},{"name":"范围","range":"97,60 – 99,99 %(m/m)"}],"search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） 范围 苯 甲苯 范围 ASTM D 7504-23","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a836fb9af14b9c0e7b1eb80","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość alkoholu metylowego","parameters":[{"name":"Zakres","range":"(0,01– 0,5) %(m/m)"}],"technique":"Metoda chromatografii gazowej z analizą warstwy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID)","techniques":["Metoda chromatografii gazowej z analizą warstwy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID)"],"computed":[],"activity":"Zawartość alkoholu metylowego\nZakres (0,01– 0,5) %(m/m)\nMetoda chromatografii gazowej z analizą warstwy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID)","reference":"PN-EN 14110:2019-05","norm_bases":["PN-EN 14110:2019-05"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Zawartość alkoholu metylowego\nZakres (0,01– 0,5) %(m/m)\nMetoda chromatografii gazowej z analizą warstwy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID) PN-EN 14110:2019-05 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Zawartosc alkoholu metylowego\nZakres (0,01– 0,5) %(m/m)\nMetoda chromatografii gazowej z analiza warstwy nadpowierzchniowej i detekcja plomieniowo-jonizacyjna (HS-GC-FID) PN-EN 14110:2019-05","categories":["petro"],"row_index":105,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Methyl alcohol content","parameters_en":[{"name":"Range","range":"(0,01– 0,5) %(m/m)"}],"search_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME) Methyl alcohol content Gas chromatography with headspace layer analysis and flame ionization detection (HS-GC-FID) Range PN-EN 14110:2019-05","technique_en":"Gas chromatography with headspace layer analysis and flame ionization detection (HS-GC-FID)","test_object_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME)","parameters_zh":[{"name":"范围","range":"(0,01– 0,5) %(m/m)"}],"search_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME） 甲醇含量 范围 PN-EN 14110:2019-05","test_object_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME）","methodology_zh":"甲醇含量"},{"_id":"6a836fb9af14b9c0e7b1eb81","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: bioetanol","methodology":"Zawartość miedzi","parameters":[{"name":"Zakres","range":"(0,07 – 0,20) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)"],"computed":[],"activity":"Zawartość miedzi\nZakres (0,07 – 0,20) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","reference":"PN-EN 15488:2009","norm_bases":["PN-EN 15488:2009"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: bioetanol Zawartość miedzi\nZakres (0,07 – 0,20) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS) PN-EN 15488:2009 Paliwa ciekle: biopaliwa ciekle: bioetanol Zawartosc miedzi\nZakres (0,07 – 0,20) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z atomizacja elektrotermiczna (ETAAS) PN-EN 15488:2009","categories":["petro"],"row_index":106,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Copper content","parameters_en":[{"name":"Range","range":"(0,07 – 0,20) mg/kg"}],"search_en":"Liquid fuels: liquid biofuels: bioethanol Copper content Electrothermal atomization atomic absorption spectrometry (ETAAS) Range PN-EN 15488:2009","technique_en":"Electrothermal atomization atomic absorption spectrometry (ETAAS)","test_object_en":"Liquid fuels: liquid biofuels: bioethanol","parameters_zh":[{"name":"范围","range":"(0,07 – 0,20) mg/kg"}],"search_zh":"液体燃料：液体生物燃料：生物乙醇 铜含量 电热原子化原子吸收光谱法（ETAAS） 范围 PN-EN 15488:2009","technique_zh":"电热原子化原子吸收光谱法（ETAAS）","methodology_zh":"铜含量","test_object_zh":"液体燃料：液体生物燃料：生物乙醇"},{"_id":"6a836fb9af14b9c0e7b1eb82","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: bioetanol","methodology":"Moc","parameters":[{"name":"Zakres","range":"(80,0 – 100,0) %(v/v)"}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"computed":[],"activity":"Moc\nZakres (80,0 – 100,0) %(v/v)\nMetoda oscylacyjna","reference":"PN-A-79528-3:2007 p. 5.2","norm_bases":["PN-A-79528-3:2007 p. 5.2"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: bioetanol Moc\nZakres (80,0 – 100,0) %(v/v)\nMetoda oscylacyjna PN-A-79528-3:2007 p. 5.2 Paliwa ciekle: biopaliwa ciekle: bioetanol Moc\nZakres (80,0 – 100,0) %(v/v)\nMetoda oscylacyjna PN-A-79528-3:2007 p. 5.2","categories":["petro"],"row_index":107,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Power","parameters_en":[{"name":"Range","range":"(80,0 – 100,0) %(v/v)"}],"search_en":"Liquid fuels: liquid biofuels: bioethanol Power Oscillation method Range PN-A-79528-3:2007 p. 5.2","technique_en":"Oscillation method","test_object_en":"Liquid fuels: liquid biofuels: bioethanol","parameters_zh":[{"name":"范围","range":"(80,0 – 100,0) %(v/v)"}],"search_zh":"液体燃料：液体生物燃料：生物乙醇 功率 振荡法 范围 PN-A-79528-3:2007 p. 5.2","technique_zh":"振荡法","methodology_zh":"功率","test_object_zh":"液体燃料：液体生物燃料：生物乙醇"},{"_id":"6a836fb9af14b9c0e7b1eb83","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: bioetanol","methodology":"Wygląd","parameters":[],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Wygląd\nMetoda wizualna","reference":"PN-EN 15769:2010","norm_bases":["PN-EN 15769:2010"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: bioetanol Wygląd\nMetoda wizualna PN-EN 15769:2010 Paliwa ciekle: biopaliwa ciekle: bioetanol Wyglad\nMetoda wizualna PN-EN 15769:2010","categories":["petro"],"row_index":108,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Appearance","search_en":"Liquid fuels: liquid biofuels: bioethanol Appearance Visual method PN-EN 15769:2010","technique_en":"Visual method","test_object_en":"Liquid fuels: liquid biofuels: bioethanol","search_zh":"液体燃料：液体生物燃料：生物乙醇 外观 目视法 PN-EN 15769:2010","technique_zh":"目视法","methodology_zh":"外观","test_object_zh":"液体燃料：液体生物燃料：生物乙醇"},{"_id":"6a836fb9af14b9c0e7b1eb84","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: bioetanol, metanol","methodology":"Gęstość w temperaturze 20°C","parameters":[{"name":"Zakres","range":"(0,780 – 0,870) g/cm3"}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"computed":[],"activity":"Gęstość w temperaturze 20°C\nZakres (0,780 – 0,870) g/cm3\nMetoda oscylacyjna","reference":"PN-EN ISO 12185:2024-08","norm_bases":["PN-EN ISO 12185:2024-08"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: bioetanol, metanol Gęstość w temperaturze 20°C\nZakres (0,780 – 0,870) g/cm3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08 Paliwa ciekle: biopaliwa ciekle: bioetanol, metanol Gestosc w temperaturze 20°C\nZakres (0,780 – 0,870) g/cm3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08","categories":["petro"],"row_index":109,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Density at 20°C","parameters_en":[{"name":"Range","range":"(0,780 – 0,870) g/cm3"}],"search_en":"Liquid fuels: liquid biofuels: bioethanol, methanol Density at 20°C Oscillation method Range PN-EN ISO 12185:2024-08","technique_en":"Oscillation method","test_object_en":"Liquid fuels: liquid biofuels: bioethanol, methanol","parameters_zh":[{"name":"范围","range":"(0,780 – 0,870) g/cm3"}],"search_zh":"振荡法 范围 PN-EN ISO 12185:2024-08","technique_zh":"振荡法"},{"_id":"6a836fb9af14b9c0e7b1eb85","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, biopaliwa ciekłe: FAME","methodology":"Pochodna liczby cetanowej","parameters":[{"name":"Zakres","range":"50,0 – 60,0"}],"technique":"Metoda z komorą spalania","techniques":["Metoda z komorą spalania"],"computed":[],"activity":"Pochodna liczby cetanowej\nZakres 50,0 – 60,0\nMetoda z komorą spalania","reference":"PN-EN 16715:2015-09","norm_bases":["PN-EN 16715:2015-09"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, biopaliwa ciekłe: FAME Pochodna liczby cetanowej\nZakres 50,0 – 60,0\nMetoda z komorą spalania PN-EN 16715:2015-09 Paliwa ciekle: olej napedowy, biopaliwa ciekle: FAME Pochodna liczby cetanowej\nZakres 50,0 – 60,0\nMetoda z komora spalania PN-EN 16715:2015-09","categories":["petro"],"row_index":110,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Derived cetane number","parameters_en":[{"name":"Range","range":"50,0 – 60,0"}],"search_en":"Liquid fuels: diesel fuel, liquid biofuels: FAME Derived cetane number Combustion chamber method Range PN-EN 16715:2015-09","technique_en":"Combustion chamber method","test_object_en":"Liquid fuels: diesel fuel, liquid biofuels: FAME","parameters_zh":[{"name":"范围","range":"50,0 – 60,0"}],"search_zh":"范围 PN-EN 16715:2015-09"},{"_id":"6a836fb9af14b9c0e7b1eb86","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: bioetanol, benzyna silnikowa z bioetanolem","methodology":"Zawartość siarki","parameters":[{"name":"Zakres","range":"(5,0 – 20,0)mg/kg"}],"technique":"Metoda fluorescencji w nadfiolecie","techniques":["Metoda fluorescencji w nadfiolecie"],"computed":[],"activity":"Zawartość siarki\nZakres (5,0 – 20,0)mg/kg\nMetoda fluorescencji w nadfiolecie","reference":"PN-EN 15486:2009","norm_bases":["PN-EN 15486:2009"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: bioetanol, benzyna silnikowa z bioetanolem Zawartość siarki\nZakres (5,0 – 20,0)mg/kg\nMetoda fluorescencji w nadfiolecie PN-EN 15486:2009 Paliwa ciekle: biopaliwa ciekle: bioetanol, benzyna silnikowa z bioetanolem Zawartosc siarki\nZakres (5,0 – 20,0)mg/kg\nMetoda fluorescencji w nadfiolecie PN-EN 15486:2009","categories":["petro"],"row_index":111,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfur content","parameters_en":[{"name":"Range","range":"(5,0 – 20,0)mg/kg"}],"search_en":"Liquid fuels: liquid biofuels: bioethanol, motor petrol with bioethanol Sulfur content Ultraviolet fluorescence method Range PN-EN 15486:2009","technique_en":"Ultraviolet fluorescence method","test_object_en":"Liquid fuels: liquid biofuels: bioethanol, motor petrol with bioethanol","parameters_zh":[{"name":"范围","range":"(5,0 – 20,0)mg/kg"}],"search_zh":"硫含量 紫外荧光法 范围 PN-EN 15486:2009","methodology_zh":"硫含量","technique_zh":"紫外荧光法"},{"_id":"6a836fb9af14b9c0e7b1eb87","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: lekki olej opałowy","methodology":"Zawartość butoksybenzenu (eteru n-butylofenylowego (BPE))","parameters":[{"name":"Zakres","range":"(0,05 – 20,00) mg/l"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrii mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrii mas (GC-MS)"],"computed":[],"activity":"Zawartość butoksybenzenu (eteru n-butylofenylowego (BPE))\nZakres (0,05 – 20,00) mg/l\nMetoda chromatografii gazowej z detekcją spektrometrii mas (GC-MS)","reference":"ILIADe 606:2024 Procedura B","norm_bases":["ILIADe 606:2024 Procedura B"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: lekki olej opałowy Zawartość butoksybenzenu (eteru n-butylofenylowego (BPE))\nZakres (0,05 – 20,00) mg/l\nMetoda chromatografii gazowej z detekcją spektrometrii mas (GC-MS) ILIADe 606:2024 Procedura B Paliwa ciekle: lekki olej opalowy Zawartosc butoksybenzenu (eteru n-butylofenylowego (BPE))\nZakres (0,05 – 20,00) mg/l\nMetoda chromatografii gazowej z detekcja spektrometrii mas (GC-MS) ILIADe 606:2024 Procedura B","categories":["petro"],"row_index":112,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Butoxybenzene (n-butyl phenyl ether (BPE)) content","parameters_en":[{"name":"Range","range":"(0,05 – 20,00) mg/l"}],"search_en":"Liquid fuels: light heating oil Butoxybenzene (n-butyl phenyl ether (BPE)) content Gas chromatography with mass spectrometry detection (GC-MS) Range ILIADe 606:2024 Procedura B","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","test_object_en":"Liquid fuels: light heating oil","parameters_zh":[{"name":"范围","range":"(0,05 – 20,00) mg/l"}],"search_zh":"气相色谱-质谱检测法（GC-MS） 范围 ILIADe 606:2024 Procedura B","technique_zh":"气相色谱-质谱检测法（GC-MS）"},{"_id":"6a836fb9af14b9c0e7b1eb88","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ropa naftowa","methodology":"Zawartość chlorków organicznych we frakcji wrzącej do 204°C","parameters":[{"name":"Zakres","range":"(1 –50) mg/kg"},{"name":"Zawartość chlorków organicznych (z obliczeń)"}],"technique":"Metoda miareczkowania mikrokulometrycznego","techniques":["Metoda miareczkowania mikrokulometrycznego"],"computed":[],"activity":"Zawartość chlorków organicznych we frakcji wrzącej do 204°C\nZakres:\nZakres (1 –50) mg/kg\nZawartość chlorków organicznych (z obliczeń)\nMetoda miareczkowania mikrokulometrycznego","reference":"ASTM D 4929-22 metoda B","norm_bases":["ASTM D 4929-22 metoda B"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ropa naftowa Zawartość chlorków organicznych we frakcji wrzącej do 204°C\nZakres:\nZakres (1 –50) mg/kg\nZawartość chlorków organicznych (z obliczeń)\nMetoda miareczkowania mikrokulometrycznego ASTM D 4929-22 metoda B Ropa naftowa Zawartosc chlorkow organicznych we frakcji wrzacej do 204°C\nZakres:\nZakres (1 –50) mg/kg\nZawartosc chlorkow organicznych (z obliczen)\nMetoda miareczkowania mikrokulometrycznego ASTM D 4929-22 metoda B","categories":["petro"],"row_index":113,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of organic chlorides in the fraction boiling up to 204°C","parameters_en":[{"name":"Range","range":"(1 –50) mg/kg"},{"name":"Organic chloride content (calculated)"}],"search_en":"Crude oil Content of organic chlorides in the fraction boiling up to 204°C Microcoulometric titration method Range Organic chloride content (calculated) ASTM D 4929-22 metoda B","technique_en":"Microcoulometric titration method","test_object_en":"Crude oil","parameters_zh":[{"name":"范围","range":"(1 –50) mg/kg"},{"name":"Zawartość chlorków organicznych (z obliczeń)"}],"search_zh":"原油 范围 ASTM D 4929-22 metoda B","test_object_zh":"原油"},{"_id":"6a836fb9af14b9c0e7b1eb89","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie rtęci","parameters":[{"name":"Zakres","range":"(0,010 – 10,0) μg/l"}],"technique":"Metoda fluorescencyjnej spektrometrii atomowej z generowaniem zimnych par (CVAFS)","techniques":["Metoda fluorescencyjnej spektrometrii atomowej z generowaniem zimnych par (CVAFS)"],"computed":[],"activity":"Stężenie rtęci\nZakres (0,010 – 10,0) μg/l\nMetoda fluorescencyjnej spektrometrii atomowej z generowaniem zimnych par (CVAFS)","reference":"PN-EN ISO 17852:2009","norm_bases":["PN-EN ISO 17852:2009"],"lab_section":"Pracownia Paliw i Aromatów PP1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie rtęci\nZakres (0,010 – 10,0) μg/l\nMetoda fluorescencyjnej spektrometrii atomowej z generowaniem zimnych par (CVAFS) PN-EN ISO 17852:2009 Woda, scieki Stezenie rteci\nZakres (0,010 – 10,0) μg/l\nMetoda fluorescencyjnej spektrometrii atomowej z generowaniem zimnych par (CVAFS) PN-EN ISO 17852:2009","categories":["water"],"row_index":114,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury concentration","parameters_en":[{"name":"Range","range":"(0,010 – 10,0) μg/l"}],"search_en":"Water, wastewater Mercury concentration Cold vapour atomic fluorescence spectrometry (CVAFS) Range PN-EN ISO 17852:2009","technique_en":"Cold vapour atomic fluorescence spectrometry (CVAFS)","test_object_en":"Water, wastewater","methodology_zh":"汞浓度","parameters_zh":[{"name":"范围","range":"(0,010 – 10,0) μg/l"}],"search_zh":"水、废水 汞浓度 冷蒸气原子荧光光谱法（CVAFS） 范围 PN-EN ISO 17852:2009","test_object_zh":"水、废水","technique_zh":"冷蒸气原子荧光光谱法（CVAFS）"},{"_id":"6a836fb9af14b9c0e7b1eb8a","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, Ropa naftowa","methodology":"Skład frakcyjny","parameters":[{"name":"Zakres","range":"(50 – 380) °C"}],"technique":"Metoda destylacyjna","techniques":["Metoda destylacyjna"],"computed":[],"activity":"Skład frakcyjny\nZakres (50 – 380) °C\nMetoda destylacyjna","reference":"PN-EN ISO 3405:2019-05 z wyłączeniem pkt 9 | ASTM D 86-23aɛ2","norm_bases":["PN-EN ISO 3405:2019-05 z wyłączeniem pkt 9","ASTM D 86-23aɛ2"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, Ropa naftowa Skład frakcyjny\nZakres (50 – 380) °C\nMetoda destylacyjna PN-EN ISO 3405:2019-05 z wyłączeniem pkt 9 | ASTM D 86-23aɛ2 Paliwa ciekle: olej napedowy, olej opalowy lekki, Ropa naftowa Sklad frakcyjny\nZakres (50 – 380) °C\nMetoda destylacyjna PN-EN ISO 3405:2019-05 z wylaczeniem pkt 9 | ASTM D 86-23aɛ2","categories":["petro"],"row_index":115,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fractional composition","parameters_en":[{"name":"Range","range":"(50 – 380) °C"}],"search_en":"Liquid fuels: diesel fuel, light heating oil, Crude oil Fractional composition Distillation method Range PN-EN ISO 3405:2019-05 z wyłączeniem pkt 9 | ASTM D 86-23aɛ2","technique_en":"Distillation method","test_object_en":"Liquid fuels: diesel fuel, light heating oil, Crude oil","parameters_zh":[{"name":"范围","range":"(50 – 380) °C"}],"search_zh":"馏程组成 蒸馏法 范围 PN-EN ISO 3405:2019-05 z wyłączeniem pkt 9 | ASTM D 86-23aɛ2","technique_zh":"蒸馏法","methodology_zh":"馏程组成"},{"_id":"6a836fb9af14b9c0e7b1eb8b","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: olej napędowy z FAME","methodology":"Skład frakcyjny","parameters":[{"name":"Zakres","range":"(50 – 380) °C"}],"technique":"Metoda destylacyjna","techniques":["Metoda destylacyjna"],"computed":[],"activity":"Skład frakcyjny\nZakres (50 – 380) °C\nMetoda destylacyjna","reference":"PN-EN ISO 3405:2019-05 z wyłączeniem pkt 9","norm_bases":["PN-EN ISO 3405:2019-05 z wyłączeniem pkt 9"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: olej napędowy z FAME Skład frakcyjny\nZakres (50 – 380) °C\nMetoda destylacyjna PN-EN ISO 3405:2019-05 z wyłączeniem pkt 9 Paliwa ciekle: biopaliwa ciekle: olej napedowy z FAME Sklad frakcyjny\nZakres (50 – 380) °C\nMetoda destylacyjna PN-EN ISO 3405:2019-05 z wylaczeniem pkt 9","categories":["petro"],"row_index":116,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fractional composition","parameters_en":[{"name":"Range","range":"(50 – 380) °C"}],"search_en":"Liquid fuels: liquid biofuels: diesel fuel with FAME Fractional composition Distillation method Range PN-EN ISO 3405:2019-05 z wyłączeniem pkt 9","technique_en":"Distillation method","test_object_en":"Liquid fuels: liquid biofuels: diesel fuel with FAME","parameters_zh":[{"name":"范围","range":"(50 – 380) °C"}],"search_zh":"馏程组成 蒸馏法 范围 PN-EN ISO 3405:2019-05 z wyłączeniem pkt 9","technique_zh":"蒸馏法","methodology_zh":"馏程组成"},{"_id":"6a836fb9af14b9c0e7b1eb8c","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, biopaliwa ciekłe: olej napędowy z FAME","methodology":"Indeks cetanowy (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Indeks cetanowy (z obliczeń)","reference":"PN-EN ISO 4264:2018-08","norm_bases":["PN-EN ISO 4264:2018-08"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, biopaliwa ciekłe: olej napędowy z FAME Indeks cetanowy (z obliczeń) PN-EN ISO 4264:2018-08 Paliwa ciekle: olej napedowy, olej opalowy lekki, biopaliwa ciekle: olej napedowy z FAME Indeks cetanowy (z obliczen) PN-EN ISO 4264:2018-08","categories":["petro"],"row_index":117,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Cetane index (calculated)","search_en":"Liquid fuels: diesel fuel, light fuel oil, liquid biofuels: diesel fuel with FAME Cetane index (calculated) PN-EN ISO 4264:2018-08","test_object_en":"Liquid fuels: diesel fuel, light fuel oil, liquid biofuels: diesel fuel with FAME","methodology_zh":"十六烷指数（计算值）","search_zh":"十六烷指数（计算值） PN-EN ISO 4264:2018-08"},{"_id":"6a836fb9af14b9c0e7b1eb8d","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki, olej opałowy ciężki, biopaliwa ciekłe: olej napędowy z FAME, estry metylowe kwasów tłuszczowych (FAME), Inne przetwory naftowe: olej popirolityczny, Ropa naftowa","methodology":"Gęstość w temperaturze 15°C","parameters":[{"name":"Zakres","range":"(630 – 1100) kg/m3"}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"computed":[],"activity":"Gęstość w temperaturze 15°C\nZakres (630 – 1100) kg/m3\nMetoda oscylacyjna","reference":"PN-EN ISO 12185:2024-08","norm_bases":["PN-EN ISO 12185:2024-08"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki, olej opałowy ciężki, biopaliwa ciekłe: olej napędowy z FAME, estry metylowe kwasów tłuszczowych (FAME), Inne przetwory naftowe: olej popirolityczny, Ropa naftowa Gęstość w temperaturze 15°C\nZakres (630 – 1100) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08 Paliwa ciekle: benzyna bezolowiowa, olej napedowy, olej opalowy lekki, olej opalowy ciezki, biopaliwa ciekle: olej napedowy z FAME, estry metylowe kwasow tluszczowych (FAME), Inne przetwory naftowe: olej popirolityczny, Ropa naftowa Gestosc w temperaturze 15°C\nZakres (630 – 1100) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08","categories":["petro"],"row_index":118,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Density at 15°C","parameters_en":[{"name":"Range","range":"(630 – 1100) kg/m3"}],"search_en":"Liquid fuels: unleaded petrol, diesel fuel, light heating oil, heavy heating oil, liquid biofuels: diesel fuel with FAME, fatty acid methyl esters (FAME), Other petroleum products: pyrolysis oil, Crude oil Density at 15°C Oscillation method Range PN-EN ISO 12185:2024-08","technique_en":"Oscillation method","test_object_en":"Liquid fuels: unleaded petrol, diesel fuel, light heating oil, heavy heating oil, liquid biofuels: diesel fuel with FAME, fatty acid methyl esters (FAME), Other petroleum products: pyrolysis oil, Crude oil","parameters_zh":[{"name":"范围","range":"(630 – 1100) kg/m3"}],"search_zh":"15°C 时的密度 振荡法 范围 PN-EN ISO 12185:2024-08","technique_zh":"振荡法","methodology_zh":"15°C 时的密度"},{"_id":"6a836fb9af14b9c0e7b1eb8e","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, olej opałowy ciężki, biopaliwa ciekłe: olej napędowy z FAME, estry metylowe kwasów tłuszczowych (FAME), Inne przetwory naftowe: pozostałość próżniowa (gudron), frakcje i/lub produkty naftowe o temperaturze wrzenia 15°C - 500°C, Ropa naftowa","methodology":"Gęstość w temperaturze 15°C","parameters":[{"name":"Zakres","range":"(646 – 1050) kg/m3"}],"technique":"Metoda areometryczna","techniques":["Metoda areometryczna"],"computed":[],"activity":"Gęstość w temperaturze 15°C\nZakres (646 – 1050) kg/m3\nMetoda areometryczna","reference":"PN-EN ISO 3675:2004","norm_bases":["PN-EN ISO 3675:2004"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, olej opałowy ciężki, biopaliwa ciekłe: olej napędowy z FAME, estry metylowe kwasów tłuszczowych (FAME), Inne przetwory naftowe: pozostałość próżniowa (gudron), frakcje i/lub produkty naftowe o temperaturze wrzenia 15°C - 500°C, Ropa naftowa Gęstość w temperaturze 15°C\nZakres (646 – 1050) kg/m3\nMetoda areometryczna PN-EN ISO 3675:2004 Paliwa ciekle: olej napedowy, olej opalowy lekki, olej opalowy ciezki, biopaliwa ciekle: olej napedowy z FAME, estry metylowe kwasow tluszczowych (FAME), Inne przetwory naftowe: pozostalosc prozniowa (gudron), frakcje i/lub produkty naftowe o temperaturze wrzenia 15°C - 500°C, Ropa naftowa Gestosc w temperaturze 15°C\nZakres (646 – 1050) kg/m3\nMetoda areometryczna PN-EN ISO 3675:2004","categories":["petro"],"row_index":119,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Density at 15°C","parameters_en":[{"name":"Range","range":"(646 – 1050) kg/m3"}],"search_en":"Liquid fuels: diesel fuel, light heating oil, heavy heating oil, liquid biofuels: diesel fuel with FAME, fatty acid methyl esters (FAME), Other petroleum products: vacuum residue (tar), petroleum fractions and/or products with a boiling temperature 15°C - 500°C, Crude oil Density at 15°C Hydrometer method Range PN-EN ISO 3675:2004","technique_en":"Hydrometer method","test_object_en":"Liquid fuels: diesel fuel, light heating oil, heavy heating oil, liquid biofuels: diesel fuel with FAME, fatty acid methyl esters (FAME), Other petroleum products: vacuum residue (tar), petroleum fractions and/or products with a boiling temperature 15°C - 500°C, Crude oil","parameters_zh":[{"name":"范围","range":"(646 – 1050) kg/m3"}],"search_zh":"15°C 时的密度 比重计法 范围 PN-EN ISO 3675:2004","methodology_zh":"15°C 时的密度","technique_zh":"比重计法"},{"_id":"6a836fb9af14b9c0e7b1eb8f","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, olej opałowy ciężki, biopaliwa ciekłe: olej napędowy z FAME, Inne przetwory naftowe: frakcje i/lub produkty naftowe o temperaturze wrzenia 20°C - 550°C, asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe","methodology":"Temperatura zapłonu","parameters":[{"name":"Zakres","range":"(40 – 220) °C"}],"technique":"Metoda zamkniętego tygla Pensky’ego-Martensa","techniques":["Metoda zamkniętego tygla Pensky’ego-Martensa"],"computed":[],"activity":"Temperatura zapłonu\nZakres (40 – 220) °C\nMetoda zamkniętego tygla Pensky’ego-Martensa","reference":"PN-EN ISO 2719:2016-08+A1:2021-06","norm_bases":["PN-EN ISO 2719:2016-08+A1:2021-06"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, olej opałowy ciężki, biopaliwa ciekłe: olej napędowy z FAME, Inne przetwory naftowe: frakcje i/lub produkty naftowe o temperaturze wrzenia 20°C - 550°C, asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe Temperatura zapłonu\nZakres (40 – 220) °C\nMetoda zamkniętego tygla Pensky’ego-Martensa PN-EN ISO 2719:2016-08+A1:2021-06 Paliwa ciekle: olej napedowy, olej opalowy lekki, olej opalowy ciezki, biopaliwa ciekle: olej napedowy z FAME, Inne przetwory naftowe: frakcje i/lub produkty naftowe o temperaturze wrzenia 20°C - 550°C, asfalty drogowe, asfalty przemyslowe i wyroby asfaltowe Temperatura zaplonu\nZakres (40 – 220) °C\nMetoda zamknietego tygla Pensky’ego-Martensa PN-EN ISO 2719:2016-08+A1:2021-06","categories":["petro"],"row_index":120,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Flash point","parameters_en":[{"name":"Range","range":"(40 – 220) °C"}],"search_en":"Liquid fuels: diesel fuel, light heating oil, heavy heating oil, liquid biofuels: diesel fuel with FAME, Other petroleum products: petroleum fractions and/or products with a boiling temperature 20°C - 550°C, road bitumens, industrial bitumens and bituminous products Flash point Pensky-Martens closed cup method Range PN-EN ISO 2719:2016-08+A1:2021-06","technique_en":"Pensky-Martens closed cup method","test_object_en":"Liquid fuels: diesel fuel, light heating oil, heavy heating oil, liquid biofuels: diesel fuel with FAME, Other petroleum products: petroleum fractions and/or products with a boiling temperature 20°C - 550°C, road bitumens, industrial bitumens and bituminous products","parameters_zh":[{"name":"范围","range":"(40 – 220) °C"}],"search_zh":"闪点 宾斯基-马丁闭口杯法 范围 PN-EN ISO 2719:2016-08+A1:2021-06","methodology_zh":"闪点","technique_zh":"宾斯基-马丁闭口杯法"},{"_id":"6a836fb9af14b9c0e7b1eb90","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki, olej opałowy ciężki, paliwo żeglugowe, Inne przetwory naftowe: pozostałość próżniowa (gudron), Ropa naftowa","methodology":"Zawartość siarki","parameters":[{"name":"Zakres","range":"(0,03 – 5,00) %(m/m)"}],"technique":"Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii","techniques":["Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii"],"computed":[],"activity":"Zawartość siarki\nZakres (0,03 – 5,00) %(m/m)\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii","reference":"PN-EN ISO 8754:2007+Ap1:2014-02","norm_bases":["PN-EN ISO 8754:2007+Ap1:2014-02"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki, olej opałowy ciężki, paliwo żeglugowe, Inne przetwory naftowe: pozostałość próżniowa (gudron), Ropa naftowa Zawartość siarki\nZakres (0,03 – 5,00) %(m/m)\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii PN-EN ISO 8754:2007+Ap1:2014-02 Paliwa ciekle: benzyna bezolowiowa, olej napedowy, olej opalowy lekki, olej opalowy ciezki, paliwo zeglugowe, Inne przetwory naftowe: pozostalosc prozniowa (gudron), Ropa naftowa Zawartosc siarki\nZakres (0,03 – 5,00) %(m/m)\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersja energii PN-EN ISO 8754:2007+Ap1:2014-02","categories":["petro"],"row_index":121,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfur content","parameters_en":[{"name":"Range","range":"(0,03 – 5,00) %(m/m)"}],"search_en":"Liquid fuels: unleaded petrol, diesel fuel, light heating oil, heavy heating oil, marine fuel, Other petroleum products: vacuum residue (tar), Crude oil Sulfur content Energy-dispersive X-ray fluorescence spectrometry Range PN-EN ISO 8754:2007+Ap1:2014-02","technique_en":"Energy-dispersive X-ray fluorescence spectrometry","test_object_en":"Liquid fuels: unleaded petrol, diesel fuel, light heating oil, heavy heating oil, marine fuel, Other petroleum products: vacuum residue (tar), Crude oil","parameters_zh":[{"name":"范围","range":"(0,03 – 5,00) %(m/m)"}],"search_zh":"硫含量 能量色散X射线荧光光谱法 范围 PN-EN ISO 8754:2007+Ap1:2014-02","methodology_zh":"硫含量","technique_zh":"能量色散X射线荧光光谱法"},{"_id":"6a836fb9af14b9c0e7b1eb91","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki","methodology":"Zawartość barwnika Solvent Red 164","parameters":[{"name":"Zakres","range":"(1,0 – 15,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość barwnika Solvent Red 164\nZakres (1,0 – 15,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-C-04426:2013-07 Metoda B","norm_bases":["PN-C-04426:2013-07 Metoda B"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki Zawartość barwnika Solvent Red 164\nZakres (1,0 – 15,0) mg/l\nMetoda spektrofotometryczna PN-C-04426:2013-07 Metoda B Paliwa ciekle: olej napedowy, olej opalowy lekki Zawartosc barwnika Solvent Red 164\nZakres (1,0 – 15,0) mg/l\nMetoda spektrofotometryczna PN-C-04426:2013-07 Metoda B","categories":["petro"],"row_index":122,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Solvent Red 164 dye content","parameters_en":[{"name":"Range","range":"(1,0 – 15,0) mg/l"}],"search_en":"Liquid fuels: diesel fuel, light fuel oil Solvent Red 164 dye content Spectrophotometric method Range PN-C-04426:2013-07 Metoda B","technique_en":"Spectrophotometric method","test_object_en":"Liquid fuels: diesel fuel, light fuel oil","parameters_zh":[{"name":"范围","range":"(1,0 – 15,0) mg/l"}],"search_zh":"液体燃料：柴油、轻质燃料油 分光光度法 范围 PN-C-04426:2013-07 Metoda B","technique_zh":"分光光度法","test_object_zh":"液体燃料：柴油、轻质燃料油"},{"_id":"6a836fb9af14b9c0e7b1eb92","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki","methodology":"Zawartość barwnika Solvent Red 19","parameters":[{"name":"Zakres","range":"(1,0 – 15,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość barwnika Solvent Red 19\nZakres (1,0 – 15,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-C-04426:2013-07 Metoda A","norm_bases":["PN-C-04426:2013-07 Metoda A"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki Zawartość barwnika Solvent Red 19\nZakres (1,0 – 15,0) mg/l\nMetoda spektrofotometryczna PN-C-04426:2013-07 Metoda A Paliwa ciekle: olej napedowy, olej opalowy lekki Zawartosc barwnika Solvent Red 19\nZakres (1,0 – 15,0) mg/l\nMetoda spektrofotometryczna PN-C-04426:2013-07 Metoda A","categories":["petro"],"row_index":123,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Solvent Red 19 dye content","parameters_en":[{"name":"Range","range":"(1,0 – 15,0) mg/l"}],"search_en":"Liquid fuels: diesel fuel, light fuel oil Solvent Red 19 dye content Spectrophotometric method Range PN-C-04426:2013-07 Metoda A","technique_en":"Spectrophotometric method","test_object_en":"Liquid fuels: diesel fuel, light fuel oil","parameters_zh":[{"name":"范围","range":"(1,0 – 15,0) mg/l"}],"search_zh":"液体燃料：柴油、轻质燃料油 溶剂红 19 着色剂含量 分光光度法 范围 PN-C-04426:2013-07 Metoda A","technique_zh":"分光光度法","test_object_zh":"液体燃料：柴油、轻质燃料油","methodology_zh":"溶剂红 19 着色剂含量"},{"_id":"6a836fb9af14b9c0e7b1eb93","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, biopaliwa ciekłe: olej napędowy z FAME","methodology":"Stabilność oksydacyjna","parameters":[{"name":"Zakres","range":"(3 – 100) g/m3"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stabilność oksydacyjna\nZakres (3 – 100) g/m3\nMetoda wagowa","reference":"PN- EN ISO 12205:2011","norm_bases":["PN- EN ISO 12205:2011"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, biopaliwa ciekłe: olej napędowy z FAME Stabilność oksydacyjna\nZakres (3 – 100) g/m3\nMetoda wagowa PN- EN ISO 12205:2011 Paliwa ciekle: olej napedowy, biopaliwa ciekle: olej napedowy z FAME Stabilnosc oksydacyjna\nZakres (3 – 100) g/m3\nMetoda wagowa PN- EN ISO 12205:2011","categories":["petro"],"row_index":124,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Oxidation stability","parameters_en":[{"name":"Range","range":"(3 – 100) g/m3"}],"search_en":"Liquid fuels: diesel fuel, liquid biofuels: diesel fuel with FAME Oxidation stability Gravimetric method Range PN- EN ISO 12205:2011","technique_en":"Gravimetric method","test_object_en":"Liquid fuels: diesel fuel, liquid biofuels: diesel fuel with FAME","parameters_zh":[{"name":"范围","range":"(3 – 100) g/m3"}],"search_zh":"液体燃料：柴油；液体生物燃料：含 FAME 的柴油 氧化安定性 重量法 范围 PN- EN ISO 12205:2011","technique_zh":"重量法","methodology_zh":"氧化安定性","test_object_zh":"液体燃料：柴油；液体生物燃料：含 FAME 的柴油"},{"_id":"6a836fb9af14b9c0e7b1eb94","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, biopaliwa ciekłe: olej napędowy z FAME","methodology":"Smarność","parameters":[{"name":"Zakres","range":"(180 – 650) μm"}],"technique":"Metoda HFRR","techniques":["Metoda HFRR"],"computed":[],"activity":"Smarność\nZakres (180 – 650) μm\nMetoda HFRR","reference":"PN-EN ISO 12156-1:2024-02","norm_bases":["PN-EN ISO 12156-1:2024-02"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, biopaliwa ciekłe: olej napędowy z FAME Smarność\nZakres (180 – 650) μm\nMetoda HFRR PN-EN ISO 12156-1:2024-02 Paliwa ciekle: olej napedowy, biopaliwa ciekle: olej napedowy z FAME Smarnosc\nZakres (180 – 650) μm\nMetoda HFRR PN-EN ISO 12156-1:2024-02","categories":["petro"],"row_index":125,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Lubricity","parameters_en":[{"name":"Range","range":"(180 – 650) μm"}],"search_en":"Liquid fuels: diesel fuel, liquid biofuels: diesel fuel with FAME Lubricity HFRR method Range PN-EN ISO 12156-1:2024-02","technique_en":"HFRR method","test_object_en":"Liquid fuels: diesel fuel, liquid biofuels: diesel fuel with FAME","parameters_zh":[{"name":"范围","range":"(180 – 650) μm"}],"search_zh":"液体燃料：柴油；液体生物燃料：含 FAME 的柴油 润滑性 高频往复试验法（HFRR） 范围 PN-EN ISO 12156-1:2024-02","methodology_zh":"润滑性","technique_zh":"高频往复试验法（HFRR）","test_object_zh":"液体燃料：柴油；液体生物燃料：含 FAME 的柴油"},{"_id":"6a836fb9af14b9c0e7b1eb95","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Inne przetwory naftowe: asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe","methodology":"Penetracja","parameters":[{"name":"Zakres","range":"(20 – 330) * 0,1 mm"}],"technique":"Metoda penetracji igłą","techniques":["Metoda penetracji igłą"],"computed":[],"activity":"Penetracja\nZakres (20 – 330) * 0,1 mm\nMetoda penetracji igłą","reference":"PN-EN 1426:2025-02","norm_bases":["PN-EN 1426:2025-02"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Inne przetwory naftowe: asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe Penetracja\nZakres (20 – 330) * 0,1 mm\nMetoda penetracji igłą PN-EN 1426:2025-02 Inne przetwory naftowe: asfalty drogowe, asfalty przemyslowe i wyroby asfaltowe Penetracja\nZakres (20 – 330) * 0,1 mm\nMetoda penetracji igla PN-EN 1426:2025-02","categories":["other"],"row_index":126,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Penetration","parameters_en":[{"name":"Range","range":"(20 – 330) * 0,1 mm"}],"search_en":"Other petroleum products: paving bitumens, industrial bitumens and bituminous products Penetration Needle penetration method Range PN-EN 1426:2025-02","technique_en":"Needle penetration method","test_object_en":"Other petroleum products: paving bitumens, industrial bitumens and bituminous products","parameters_zh":[{"name":"范围","range":"(20 – 330) * 0,1 mm"}],"search_zh":"其他石油加工品：道路沥青、工业沥青与沥青制品 针入度 针入度法 范围 PN-EN 1426:2025-02","test_object_zh":"其他石油加工品：道路沥青、工业沥青与沥青制品","methodology_zh":"针入度","technique_zh":"针入度法"},{"_id":"6a836fb9af14b9c0e7b1eb96","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Inne przetwory naftowe: asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe","methodology":"Temperatura mięknienia","parameters":[{"name":"Zakres","range":"(30 – 110) °C"}],"technique":"Metoda Pierścień i Kula","techniques":["Metoda Pierścień i Kula"],"computed":[],"activity":"Temperatura mięknienia\nZakres (30 – 110) °C\nMetoda Pierścień i Kula","reference":"PN-EN 1427:2015-08","norm_bases":["PN-EN 1427:2015-08"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Inne przetwory naftowe: asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe Temperatura mięknienia\nZakres (30 – 110) °C\nMetoda Pierścień i Kula PN-EN 1427:2015-08 Inne przetwory naftowe: asfalty drogowe, asfalty przemyslowe i wyroby asfaltowe Temperatura mieknienia\nZakres (30 – 110) °C\nMetoda Pierscien i Kula PN-EN 1427:2015-08","categories":["other"],"row_index":127,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Softening point","parameters_en":[{"name":"Range","range":"(30 – 110) °C"}],"search_en":"Other petroleum products: paving bitumens, industrial bitumens and bituminous products Softening point Ring and Ball method Range PN-EN 1427:2015-08","technique_en":"Ring and Ball method","test_object_en":"Other petroleum products: paving bitumens, industrial bitumens and bituminous products","parameters_zh":[{"name":"范围","range":"(30 – 110) °C"}],"search_zh":"其他石油加工品：道路沥青、工业沥青与沥青制品 软化点温度 环球法 范围 PN-EN 1427:2015-08","methodology_zh":"软化点温度","test_object_zh":"其他石油加工品：道路沥青、工业沥青与沥青制品","technique_zh":"环球法"},{"_id":"6a836fb9af14b9c0e7b1eb97","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Inne przetwory naftowe: asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe","methodology":"Temperatura łamliwości w ujemnych temperaturach","parameters":[{"name":"[0","range":"(-30)] °C"}],"technique":"Metoda Fraassa","techniques":["Metoda Fraassa"],"computed":[],"activity":"Temperatura łamliwości w ujemnych temperaturach\n[0 (-30)] °C\nMetoda Fraassa","reference":"PN-EN 12593:2015-08","norm_bases":["PN-EN 12593:2015-08"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Inne przetwory naftowe: asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe Temperatura łamliwości w ujemnych temperaturach\n[0 (-30)] °C\nMetoda Fraassa PN-EN 12593:2015-08 Inne przetwory naftowe: asfalty drogowe, asfalty przemyslowe i wyroby asfaltowe Temperatura lamliwosci w ujemnych temperaturach\n[0 (-30)] °C\nMetoda Fraassa PN-EN 12593:2015-08","categories":["other"],"row_index":128,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Brittleness temperature at sub-zero temperatures","parameters_en":[{"name":"[0","range":"(-30)] °C"}],"search_en":"Other petroleum products: paving bitumens, industrial bitumens and bituminous products Brittleness temperature at sub-zero temperatures Fraass method [0 PN-EN 12593:2015-08","technique_en":"Fraass method","test_object_en":"Other petroleum products: paving bitumens, industrial bitumens and bituminous products","search_zh":"其他石油加工品：道路沥青、工业沥青与沥青制品 PN-EN 12593:2015-08","test_object_zh":"其他石油加工品：道路沥青、工业沥青与沥青制品"},{"_id":"6a836fb9af14b9c0e7b1eb98","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Inne przetwory naftowe: asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe","methodology":"Zawartość parafiny","parameters":[{"name":"Zakres","range":"(1,0 – 3,5) %(m/m)"}],"technique":"Metoda destylacyjna","techniques":["Metoda destylacyjna"],"computed":[],"activity":"Zawartość parafiny\nZakres (1,0 – 3,5) %(m/m)\nMetoda destylacyjna","reference":"PN-EN 12606-1:2015-08","norm_bases":["PN-EN 12606-1:2015-08"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Inne przetwory naftowe: asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe Zawartość parafiny\nZakres (1,0 – 3,5) %(m/m)\nMetoda destylacyjna PN-EN 12606-1:2015-08 Inne przetwory naftowe: asfalty drogowe, asfalty przemyslowe i wyroby asfaltowe Zawartosc parafiny\nZakres (1,0 – 3,5) %(m/m)\nMetoda destylacyjna PN-EN 12606-1:2015-08","categories":["other"],"row_index":129,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Paraffin content","parameters_en":[{"name":"Range","range":"(1,0 – 3,5) %(m/m)"}],"search_en":"Other petroleum products: paving bitumens, industrial bitumens and bituminous products Paraffin content Distillation method Range PN-EN 12606-1:2015-08","technique_en":"Distillation method","test_object_en":"Other petroleum products: paving bitumens, industrial bitumens and bituminous products","parameters_zh":[{"name":"范围","range":"(1,0 – 3,5) %(m/m)"}],"search_zh":"其他石油加工品：道路沥青、工业沥青与沥青制品 蒸馏法 范围 PN-EN 12606-1:2015-08","technique_zh":"蒸馏法","test_object_zh":"其他石油加工品：道路沥青、工业沥青与沥青制品"},{"_id":"6a836fb9af14b9c0e7b1eb99","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Inne przetwory naftowe: asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe","methodology":"Rozpuszczalność","parameters":[{"name":"Zakres","range":"do 100,00 %(m/m)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Rozpuszczalność\nZakres do 100,00 %(m/m)\nMetoda wagowa","reference":"PN-EN 12592:2014-12","norm_bases":["PN-EN 12592:2014-12"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Inne przetwory naftowe: asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe Rozpuszczalność\nZakres do 100,00 %(m/m)\nMetoda wagowa PN-EN 12592:2014-12 Inne przetwory naftowe: asfalty drogowe, asfalty przemyslowe i wyroby asfaltowe Rozpuszczalnosc\nZakres do 100,00 %(m/m)\nMetoda wagowa PN-EN 12592:2014-12","categories":["other"],"row_index":130,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Solubility","parameters_en":[{"name":"Range","range":"do 100,00 %(m/m)"}],"search_en":"Other petroleum products: paving bitumens, industrial bitumens and bituminous products Solubility Gravimetric method Range PN-EN 12592:2014-12","technique_en":"Gravimetric method","test_object_en":"Other petroleum products: paving bitumens, industrial bitumens and bituminous products","parameters_zh":[{"name":"范围","range":"do 100,00 %(m/m)"}],"search_zh":"其他石油加工品：道路沥青、工业沥青与沥青制品 重量法 范围 PN-EN 12592:2014-12","technique_zh":"重量法","test_object_zh":"其他石油加工品：道路沥青、工业沥青与沥青制品"},{"_id":"6a836fb9af14b9c0e7b1eb9a","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Inne przetwory naftowe: asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe","methodology":"Odporność na starzenie pod wpływem ciepła i powietrza","parameters":[{"name":"procentowa zmiana masy [(-0,20)","range":"(+0,20)] %(m/m)"},{"name":"Procent pozostałej penetracji w temperaturze 25 °C ( z obliczeń) Zmiana temperatury mięknienia pierścień i kula (w °C) (z obliczeń)"}],"technique":"Metoda RTFOT","techniques":["Metoda RTFOT"],"computed":[],"activity":"Odporność na starzenie pod wpływem ciepła i powietrza\nZakres:\nprocentowa zmiana masy [(-0,20) (+0,20)] %(m/m)\nProcent pozostałej penetracji w temperaturze 25 °C ( z obliczeń) Zmiana temperatury mięknienia pierścień i kula (w °C) (z obliczeń)\nMetoda RTFOT","reference":"PN-EN 12607-1:2025-02","norm_bases":["PN-EN 12607-1:2025-02"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Inne przetwory naftowe: asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe Odporność na starzenie pod wpływem ciepła i powietrza\nZakres:\nprocentowa zmiana masy [(-0,20) (+0,20)] %(m/m)\nProcent pozostałej penetracji w temperaturze 25 °C ( z obliczeń) Zmiana temperatury mięknienia pierścień i kula (w °C) (z obliczeń)\nMetoda RTFOT PN-EN 12607-1:2025-02 Inne przetwory naftowe: asfalty drogowe, asfalty przemyslowe i wyroby asfaltowe Odpornosc na starzenie pod wplywem ciepla i powietrza\nZakres:\nprocentowa zmiana masy [(-0,20) (+0,20)] %(m/m)\nProcent pozostalej penetracji w temperaturze 25 °C ( z obliczen) Zmiana temperatury mieknienia pierscien i kula (w °C) (z obliczen)\nMetoda RTFOT PN-EN 12607-1:2025-02","categories":["other"],"row_index":131,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Resistance to ageing under the influence of heat and air","search_en":"Other petroleum products: paving bitumens, industrial bitumens and bituminous products Resistance to ageing under the influence of heat and air RTFOT method PN-EN 12607-1:2025-02","technique_en":"RTFOT method","test_object_en":"Other petroleum products: paving bitumens, industrial bitumens and bituminous products","search_zh":"其他石油加工品：道路沥青、工业沥青与沥青制品 旋转薄膜烘箱法（RTFOT） PN-EN 12607-1:2025-02","test_object_zh":"其他石油加工品：道路沥青、工业沥青与沥青制品","technique_zh":"旋转薄膜烘箱法（RTFOT）"},{"_id":"6a836fb9af14b9c0e7b1eb9b","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Inne przetwory naftowe: asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe","methodology":"Odporność na starzenie pod wpływem ciepła i powietrza","parameters":[{"name":"Zakres","range":"procentowa zmiana masy"},{"name":"[(-1,5)","range":"(+2,0)] %(m/m)"}],"technique":"Metoda TFOT","techniques":["Metoda TFOT"],"computed":[],"activity":"Odporność na starzenie pod wpływem ciepła i powietrza\nZakres:\nZakres procentowa zmiana masy\n[(-1,5) (+2,0)] %(m/m)\nMetoda TFOT","reference":"PN-EN 12607-2:2014-12","norm_bases":["PN-EN 12607-2:2014-12"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Inne przetwory naftowe: asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe Odporność na starzenie pod wpływem ciepła i powietrza\nZakres:\nZakres procentowa zmiana masy\n[(-1,5) (+2,0)] %(m/m)\nMetoda TFOT PN-EN 12607-2:2014-12 Inne przetwory naftowe: asfalty drogowe, asfalty przemyslowe i wyroby asfaltowe Odpornosc na starzenie pod wplywem ciepla i powietrza\nZakres:\nZakres procentowa zmiana masy\n[(-1,5) (+2,0)] %(m/m)\nMetoda TFOT PN-EN 12607-2:2014-12","categories":["other"],"row_index":132,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Resistance to ageing under the influence of heat and air","parameters_en":[{"name":"Range","range":"procentowa zmiana masy"},{"name":"[(-1,5)","range":"(+2,0)] %(m/m)"}],"search_en":"Other petroleum products: paving bitumens, industrial bitumens and bituminous products Resistance to ageing under the influence of heat and air TFOT method Range [(-1,5) PN-EN 12607-2:2014-12","technique_en":"TFOT method","test_object_en":"Other petroleum products: paving bitumens, industrial bitumens and bituminous products","parameters_zh":[{"name":"范围","range":"procentowa zmiana masy"},{"name":"[(-1,5)","range":"(+2,0)] %(m/m)"}],"search_zh":"其他石油加工品：道路沥青、工业沥青与沥青制品 范围 PN-EN 12607-2:2014-12","test_object_zh":"其他石油加工品：道路沥青、工业沥青与沥青制品"},{"_id":"6a836fb9af14b9c0e7b1eb9c","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Inne przetwory naftowe: asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe","methodology":"Zawartość wody","parameters":[{"name":"Zakres","range":"(0 – 25,0) %(v/v) %(V/m)"}],"technique":"Metoda destylacyjna","techniques":["Metoda destylacyjna"],"computed":[],"activity":"Zawartość wody\nZakres (0 – 25,0) %(v/v) %(V/m)\nMetoda destylacyjna","reference":"ASTM D 95-23ɛ1","norm_bases":["ASTM D 95-23ɛ1"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Inne przetwory naftowe: asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe Zawartość wody\nZakres (0 – 25,0) %(v/v) %(V/m)\nMetoda destylacyjna ASTM D 95-23ɛ1 Inne przetwory naftowe: asfalty drogowe, asfalty przemyslowe i wyroby asfaltowe Zawartosc wody\nZakres (0 – 25,0) %(v/v) %(V/m)\nMetoda destylacyjna ASTM D 95-23ɛ1","categories":["water"],"row_index":133,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water content","parameters_en":[{"name":"Range","range":"(0 – 25,0) %(v/v) %(V/m)"}],"search_en":"Other petroleum products: paving bitumens, industrial bitumens and bituminous products Water content Distillation method Range ASTM D 95-23ɛ1","technique_en":"Distillation method","test_object_en":"Other petroleum products: paving bitumens, industrial bitumens and bituminous products","methodology_zh":"水分含量","parameters_zh":[{"name":"范围","range":"(0 – 25,0) %(v/v) %(V/m)"}],"search_zh":"其他石油加工品：道路沥青、工业沥青与沥青制品 水分含量 蒸馏法 范围 ASTM D 95-23ɛ1","technique_zh":"蒸馏法","test_object_zh":"其他石油加工品：道路沥青、工业沥青与沥青制品"},{"_id":"6a836fb9af14b9c0e7b1eb9d","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Inne przetwory naftowe: asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe","methodology":"Lepkość dynamiczna w temp. 60 °C .","parameters":[{"name":"Zakres","range":"(50 – 8000) Pa s"}],"technique":"Metoda kapilarna","techniques":["Metoda kapilarna"],"computed":[],"activity":"Lepkość dynamiczna w temp. 60 °C .\nZakres (50 – 8000) Pa s\nMetoda kapilarna","reference":"PN-EN 12596:2024-01","norm_bases":["PN-EN 12596:2024-01"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Inne przetwory naftowe: asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe Lepkość dynamiczna w temp. 60 °C .\nZakres (50 – 8000) Pa s\nMetoda kapilarna PN-EN 12596:2024-01 Inne przetwory naftowe: asfalty drogowe, asfalty przemyslowe i wyroby asfaltowe Lepkosc dynamiczna w temp. 60 °C .\nZakres (50 – 8000) Pa s\nMetoda kapilarna PN-EN 12596:2024-01","categories":["other"],"row_index":134,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dynamic viscosity at 60 °C .","parameters_en":[{"name":"Range","range":"(50 – 8000) Pa s"}],"search_en":"Other petroleum products: paving bitumens, industrial bitumens and bituminous products Dynamic viscosity at 60 °C . Capillary method Range PN-EN 12596:2024-01","technique_en":"Capillary method","test_object_en":"Other petroleum products: paving bitumens, industrial bitumens and bituminous products","parameters_zh":[{"name":"范围","range":"(50 – 8000) Pa s"}],"search_zh":"其他石油加工品：道路沥青、工业沥青与沥青制品 毛细管法 范围 PN-EN 12596:2024-01","technique_zh":"毛细管法","test_object_zh":"其他石油加工品：道路沥青、工业沥青与沥青制品"},{"_id":"6a836fb9af14b9c0e7b1eb9e","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Inne przetwory naftowe: asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe","methodology":"Stabilność podczas magazynowania (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stabilność podczas magazynowania (z obliczeń)","reference":"PN-EN 13399:2017-12","norm_bases":["PN-EN 13399:2017-12"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Inne przetwory naftowe: asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe Stabilność podczas magazynowania (z obliczeń) PN-EN 13399:2017-12 Inne przetwory naftowe: asfalty drogowe, asfalty przemyslowe i wyroby asfaltowe Stabilnosc podczas magazynowania (z obliczen) PN-EN 13399:2017-12","categories":["other"],"row_index":135,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Stability during storage (calculated)","search_en":"Other petroleum products: paving bitumens, industrial bitumens and bituminous products Stability during storage (calculated) PN-EN 13399:2017-12","test_object_en":"Other petroleum products: paving bitumens, industrial bitumens and bituminous products","search_zh":"其他石油加工品：道路沥青、工业沥青与沥青制品 PN-EN 13399:2017-12","test_object_zh":"其他石油加工品：道路沥青、工业沥青与沥青制品"},{"_id":"6a836fb9af14b9c0e7b1eb9f","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Inne przetwory naftowe: asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe","methodology":"Ubytek masy po ogrzaniu","parameters":[{"name":"Zakres","range":"(0,02 – 0,5) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Ubytek masy po ogrzaniu\nZakres (0,02 – 0,5) %\nMetoda wagowa","reference":"PN-EN 13303:2017-10","norm_bases":["PN-EN 13303:2017-10"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Inne przetwory naftowe: asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe Ubytek masy po ogrzaniu\nZakres (0,02 – 0,5) %\nMetoda wagowa PN-EN 13303:2017-10 Inne przetwory naftowe: asfalty drogowe, asfalty przemyslowe i wyroby asfaltowe Ubytek masy po ogrzaniu\nZakres (0,02 – 0,5) %\nMetoda wagowa PN-EN 13303:2017-10","categories":["other"],"row_index":136,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mass loss after heating","parameters_en":[{"name":"Range","range":"(0,02 – 0,5) %"}],"search_en":"Other petroleum products: paving bitumens, industrial bitumens and bituminous products Mass loss after heating Gravimetric method Range PN-EN 13303:2017-10","technique_en":"Gravimetric method","test_object_en":"Other petroleum products: paving bitumens, industrial bitumens and bituminous products","parameters_zh":[{"name":"范围","range":"(0,02 – 0,5) %"}],"search_zh":"其他石油加工品：道路沥青、工业沥青与沥青制品 重量法 范围 PN-EN 13303:2017-10","technique_zh":"重量法","test_object_zh":"其他石油加工品：道路沥青、工业沥青与沥青制品"},{"_id":"6a836fb9af14b9c0e7b1eba0","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Inne przetwory naftowe: asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe","methodology":"Nawrót sprężysty","parameters":[{"name":"Zakres","range":"(15 – 98) %"}],"technique":"Metoda duktylometryczna","techniques":["Metoda duktylometryczna"],"computed":[],"activity":"Nawrót sprężysty\nZakres (15 – 98) %\nMetoda duktylometryczna","reference":"PN-EN 13398:2017-12","norm_bases":["PN-EN 13398:2017-12"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Inne przetwory naftowe: asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe Nawrót sprężysty\nZakres (15 – 98) %\nMetoda duktylometryczna PN-EN 13398:2017-12 Inne przetwory naftowe: asfalty drogowe, asfalty przemyslowe i wyroby asfaltowe Nawrot sprezysty\nZakres (15 – 98) %\nMetoda duktylometryczna PN-EN 13398:2017-12","categories":["other"],"row_index":137,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Elastic recovery","parameters_en":[{"name":"Range","range":"(15 – 98) %"}],"search_en":"Other petroleum products: paving bitumens, industrial bitumens and bituminous products Elastic recovery Ductilometric method Range PN-EN 13398:2017-12","technique_en":"Ductilometric method","test_object_en":"Other petroleum products: paving bitumens, industrial bitumens and bituminous products","parameters_zh":[{"name":"范围","range":"(15 – 98) %"}],"search_zh":"其他石油加工品：道路沥青、工业沥青与沥青制品 弹性回复 延度仪法 范围 PN-EN 13398:2017-12","test_object_zh":"其他石油加工品：道路沥青、工业沥青与沥青制品","methodology_zh":"弹性回复","technique_zh":"延度仪法"},{"_id":"6a836fb9af14b9c0e7b1eba1","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Inne przetwory naftowe: asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe","methodology":"Gęstość i gęstość względna","parameters":[{"name":"Zakres","range":"(940 – 1030) kg/m3"}],"technique":"Metoda piknometryczna","techniques":["Metoda piknometryczna"],"computed":[],"activity":"Gęstość i gęstość względna\nZakres (940 – 1030) kg/m3\nMetoda piknometryczna","reference":"PN-EN 15326+A1:2010","norm_bases":["PN-EN 15326+A1:2010"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Inne przetwory naftowe: asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe Gęstość i gęstość względna\nZakres (940 – 1030) kg/m3\nMetoda piknometryczna PN-EN 15326+A1:2010 Inne przetwory naftowe: asfalty drogowe, asfalty przemyslowe i wyroby asfaltowe Gestosc i gestosc wzgledna\nZakres (940 – 1030) kg/m3\nMetoda piknometryczna PN-EN 15326+A1:2010","categories":["other"],"row_index":138,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Density and relative density","parameters_en":[{"name":"Range","range":"(940 – 1030) kg/m3"}],"search_en":"Other petroleum products: paving bitumens, industrial bitumens and bituminous products Density and relative density Pycnometric method Range PN-EN 15326+A1:2010","technique_en":"Pycnometric method","test_object_en":"Other petroleum products: paving bitumens, industrial bitumens and bituminous products","parameters_zh":[{"name":"范围","range":"(940 – 1030) kg/m3"}],"search_zh":"其他石油加工品：道路沥青、工业沥青与沥青制品 比重瓶法 范围 PN-EN 15326+A1:2010","technique_zh":"比重瓶法","test_object_zh":"其他石油加工品：道路沥青、工业沥青与沥青制品"},{"_id":"6a836fb9af14b9c0e7b1eba2","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Inne przetwory naftowe: asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe","methodology":"Lepkość kinematyczna w temp. 135°C","parameters":[{"name":"Zakres","range":"(20 – 2000) mm2/s"}],"technique":"Metoda kapilarna","techniques":["Metoda kapilarna"],"computed":[],"activity":"Lepkość kinematyczna w temp. 135°C\nZakres (20 – 2000) mm2/s\nMetoda kapilarna","reference":"PN-EN 12595:2024-01","norm_bases":["PN-EN 12595:2024-01"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Inne przetwory naftowe: asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe Lepkość kinematyczna w temp. 135°C\nZakres (20 – 2000) mm2/s\nMetoda kapilarna PN-EN 12595:2024-01 Inne przetwory naftowe: asfalty drogowe, asfalty przemyslowe i wyroby asfaltowe Lepkosc kinematyczna w temp. 135°C\nZakres (20 – 2000) mm2/s\nMetoda kapilarna PN-EN 12595:2024-01","categories":["other"],"row_index":139,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kinematic viscosity at 135°C","parameters_en":[{"name":"Range","range":"(20 – 2000) mm2/s"}],"search_en":"Other petroleum products: paving bitumens, industrial bitumens and bituminous products Kinematic viscosity at 135°C Capillary method Range PN-EN 12595:2024-01","technique_en":"Capillary method","test_object_en":"Other petroleum products: paving bitumens, industrial bitumens and bituminous products","parameters_zh":[{"name":"范围","range":"(20 – 2000) mm2/s"}],"search_zh":"其他石油加工品：道路沥青、工业沥青与沥青制品 毛细管法 范围 PN-EN 12595:2024-01","technique_zh":"毛细管法","test_object_zh":"其他石油加工品：道路沥青、工业沥青与沥青制品"},{"_id":"6a836fb9af14b9c0e7b1eba3","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Inne przetwory naftowe: asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe","methodology":"Siła rozciągania","parameters":[{"name":"Zakres","range":"(1,0 – 10,0) J/cm2"},{"name":"Energia odkształcenia (z obliczeń)"}],"technique":"Metoda duktylometryczna","techniques":["Metoda duktylometryczna"],"computed":[],"activity":"Siła rozciągania\nZakres:\nZakres (1,0 – 10,0) J/cm2\nEnergia odkształcenia (z obliczeń)\nMetoda duktylometryczna","reference":"PN-EN 13589:2018-08","norm_bases":["PN-EN 13589:2018-08"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Inne przetwory naftowe: asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe Siła rozciągania\nZakres:\nZakres (1,0 – 10,0) J/cm2\nEnergia odkształcenia (z obliczeń)\nMetoda duktylometryczna PN-EN 13589:2018-08 Inne przetwory naftowe: asfalty drogowe, asfalty przemyslowe i wyroby asfaltowe Sila rozciagania\nZakres:\nZakres (1,0 – 10,0) J/cm2\nEnergia odksztalcenia (z obliczen)\nMetoda duktylometryczna PN-EN 13589:2018-08","categories":["other"],"row_index":140,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Tensile force","parameters_en":[{"name":"Range","range":"(1,0 – 10,0) J/cm2"},{"name":"Deformation energy (calculated)"}],"search_en":"Other petroleum products: paving bitumens, industrial bitumens and bituminous products Tensile force Ductilometric method Range Deformation energy (calculated) PN-EN 13589:2018-08","technique_en":"Ductilometric method","test_object_en":"Other petroleum products: paving bitumens, industrial bitumens and bituminous products","parameters_zh":[{"name":"范围","range":"(1,0 – 10,0) J/cm2"},{"name":"Energia odkształcenia (z obliczeń)"}],"search_zh":"其他石油加工品：道路沥青、工业沥青与沥青制品 延度仪法 范围 PN-EN 13589:2018-08","test_object_zh":"其他石油加工品：道路沥青、工业沥青与沥青制品","technique_zh":"延度仪法"},{"_id":"6a836fb9af14b9c0e7b1eba4","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ropa naftowa","methodology":"Zawartość wody","parameters":[{"name":"Zakres","range":"(0 – 1,0) %(v/v)"}],"technique":"Metoda destylacyjna","techniques":["Metoda destylacyjna"],"computed":[],"activity":"Zawartość wody\nZakres (0 – 1,0) %(v/v)\nMetoda destylacyjna","reference":"PN-EN ISO 9029:2005 | ASTM D 4006-22","norm_bases":["PN-EN ISO 9029:2005","ASTM D 4006-22"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ropa naftowa Zawartość wody\nZakres (0 – 1,0) %(v/v)\nMetoda destylacyjna PN-EN ISO 9029:2005 | ASTM D 4006-22 Ropa naftowa Zawartosc wody\nZakres (0 – 1,0) %(v/v)\nMetoda destylacyjna PN-EN ISO 9029:2005 | ASTM D 4006-22","categories":["water","petro"],"row_index":141,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water content","parameters_en":[{"name":"Range","range":"(0 – 1,0) %(v/v)"}],"search_en":"Crude oil Water content Distillation method Range PN-EN ISO 9029:2005 | ASTM D 4006-22","technique_en":"Distillation method","test_object_en":"Crude oil","methodology_zh":"水分含量","parameters_zh":[{"name":"范围","range":"(0 – 1,0) %(v/v)"}],"search_zh":"原油 水分含量 蒸馏法 范围 PN-EN ISO 9029:2005 | ASTM D 4006-22","technique_zh":"蒸馏法","test_object_zh":"原油"},{"_id":"6a836fb9af14b9c0e7b1eba5","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ropa naftowa","methodology":"Gęstość","parameters":[{"name":"Zakres","range":"(750,0 – 950,0) kg/m3"}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"computed":[],"activity":"Gęstość\nZakres (750,0 – 950,0) kg/m3\nMetoda oscylacyjna","reference":"ASTM D 5002-22","norm_bases":["ASTM D 5002-22"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ropa naftowa Gęstość\nZakres (750,0 – 950,0) kg/m3\nMetoda oscylacyjna ASTM D 5002-22 Ropa naftowa Gestosc\nZakres (750,0 – 950,0) kg/m3\nMetoda oscylacyjna ASTM D 5002-22","categories":["petro"],"row_index":142,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Density","parameters_en":[{"name":"Range","range":"(750,0 – 950,0) kg/m3"}],"search_en":"Crude oil Density Oscillation method Range ASTM D 5002-22","technique_en":"Oscillation method","test_object_en":"Crude oil","methodology_zh":"密度","parameters_zh":[{"name":"范围","range":"(750,0 – 950,0) kg/m3"}],"search_zh":"原油 密度 振荡法 范围 ASTM D 5002-22","technique_zh":"振荡法","test_object_zh":"原油"},{"_id":"6a836fb9af14b9c0e7b1eba6","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ropa naftowa","methodology":"Zawartość wody","parameters":[{"name":"Zakres","range":"(0,02 – 2,00) %(m/m)"}],"technique":"Metoda miareczkowania potencjometrycznego","techniques":["Metoda miareczkowania potencjometrycznego"],"computed":[],"activity":"Zawartość wody\nZakres (0,02 – 2,00) %(m/m)\nMetoda miareczkowania potencjometrycznego","reference":"ASTM D 4377-00 (2011)","norm_bases":["ASTM D 4377-00 (2011)"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ropa naftowa Zawartość wody\nZakres (0,02 – 2,00) %(m/m)\nMetoda miareczkowania potencjometrycznego ASTM D 4377-00 (2011) Ropa naftowa Zawartosc wody\nZakres (0,02 – 2,00) %(m/m)\nMetoda miareczkowania potencjometrycznego ASTM D 4377-00 (2011)","categories":["water","petro"],"row_index":143,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water content","parameters_en":[{"name":"Range","range":"(0,02 – 2,00) %(m/m)"}],"search_en":"Crude oil Water content Potentiometric titration method Range ASTM D 4377-00 (2011)","technique_en":"Potentiometric titration method","test_object_en":"Crude oil","methodology_zh":"水分含量","parameters_zh":[{"name":"范围","range":"(0,02 – 2,00) %(m/m)"}],"search_zh":"原油 水分含量 电位滴定法 范围 ASTM D 4377-00 (2011)","technique_zh":"电位滴定法","test_object_zh":"原油"},{"_id":"6a836fb9af14b9c0e7b1eba7","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ropa naftowa","methodology":"Zawartość wody","parameters":[{"name":"Zakres","range":"(0,02 – 5,00) % (m/m lub V/V)"}],"technique":"Metoda miareczkowania kulometrycznego","techniques":["Metoda miareczkowania kulometrycznego"],"computed":[],"activity":"Zawartość wody\nZakres (0,02 – 5,00) % (m/m lub V/V)\nMetoda miareczkowania kulometrycznego","reference":"ASTM D 4928-12(2018)","norm_bases":["ASTM D 4928-12(2018)"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ropa naftowa Zawartość wody\nZakres (0,02 – 5,00) % (m/m lub V/V)\nMetoda miareczkowania kulometrycznego ASTM D 4928-12(2018) Ropa naftowa Zawartosc wody\nZakres (0,02 – 5,00) % (m/m lub V/V)\nMetoda miareczkowania kulometrycznego ASTM D 4928-12(2018)","categories":["water","petro"],"row_index":144,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water content","parameters_en":[{"name":"Range","range":"(0,02 – 5,00) % (m/m lub V/V)"}],"search_en":"Crude oil Water content Coulometric titration method Range ASTM D 4928-12(2018)","technique_en":"Coulometric titration method","test_object_en":"Crude oil","methodology_zh":"水分含量","parameters_zh":[{"name":"范围","range":"(0,02 – 5,00) % (m/m lub V/V)"}],"search_zh":"原油 水分含量 库仑滴定法 范围 ASTM D 4928-12(2018)","technique_zh":"库仑滴定法","test_object_zh":"原油"},{"_id":"6a836fb9af14b9c0e7b1eba8","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ropa naftowa","methodology":"Skład frakcyjny","parameters":[{"name":"Zakres","range":"(30 – 300)°C"}],"technique":"Metoda destylacyjna","techniques":["Metoda destylacyjna"],"computed":[],"activity":"Skład frakcyjny\nZakres (30 – 300)°C\nMetoda destylacyjna","reference":"GOST 2177-99 metoda B","norm_bases":["GOST 2177-99 metoda B"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ropa naftowa Skład frakcyjny\nZakres (30 – 300)°C\nMetoda destylacyjna GOST 2177-99 metoda B Ropa naftowa Sklad frakcyjny\nZakres (30 – 300)°C\nMetoda destylacyjna GOST 2177-99 metoda B","categories":["petro"],"row_index":145,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fractional composition","parameters_en":[{"name":"Range","range":"(30 – 300)°C"}],"search_en":"Crude oil Fractional composition Distillation method Range GOST 2177-99 metoda B","technique_en":"Distillation method","test_object_en":"Crude oil","parameters_zh":[{"name":"范围","range":"(30 – 300)°C"}],"search_zh":"原油 馏程组成 蒸馏法 范围 GOST 2177-99 metoda B","technique_zh":"蒸馏法","methodology_zh":"馏程组成","test_object_zh":"原油"},{"_id":"6a836fb9af14b9c0e7b1eba9","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ropa naftowa","methodology":"Skład frakcyjny","parameters":[{"name":"[(-1)","range":"(+400)] °C"}],"technique":"Metoda destylacyjna","techniques":["Metoda destylacyjna"],"computed":[],"activity":"Skład frakcyjny\n[(-1) (+400)] °C\nMetoda destylacyjna","reference":"ASTM D 2892-25","norm_bases":["ASTM D 2892-25"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ropa naftowa Skład frakcyjny\n[(-1) (+400)] °C\nMetoda destylacyjna ASTM D 2892-25 Ropa naftowa Sklad frakcyjny\n[(-1) (+400)] °C\nMetoda destylacyjna ASTM D 2892-25","categories":["petro"],"row_index":146,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fractional composition","parameters_en":[{"name":"[(-1)","range":"(+400)] °C"}],"search_en":"Crude oil Fractional composition Distillation method [(-1) ASTM D 2892-25","technique_en":"Distillation method","test_object_en":"Crude oil","search_zh":"原油 馏程组成 蒸馏法 ASTM D 2892-25","technique_zh":"蒸馏法","methodology_zh":"馏程组成","test_object_zh":"原油"},{"_id":"6a836fb9af14b9c0e7b1ebaa","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ropa naftowa – pozostałość po destylacji wg ASTM D 2892","methodology":"Skład frakcyjny","parameters":[{"name":"Zakres","range":"(380 – 565) °C"}],"technique":"Metoda destylacyjna","techniques":["Metoda destylacyjna"],"computed":[],"activity":"Skład frakcyjny\nZakres (380 – 565) °C\nMetoda destylacyjna","reference":"ASTM D 5236-25","norm_bases":["ASTM D 5236-25"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ropa naftowa – pozostałość po destylacji wg ASTM D 2892 Skład frakcyjny\nZakres (380 – 565) °C\nMetoda destylacyjna ASTM D 5236-25 Ropa naftowa – pozostalosc po destylacji wg ASTM D 2892 Sklad frakcyjny\nZakres (380 – 565) °C\nMetoda destylacyjna ASTM D 5236-25","categories":["petro"],"row_index":147,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fractional composition","parameters_en":[{"name":"Range","range":"(380 – 565) °C"}],"search_en":"Crude oil – distillation residue according to ASTM D 2892 Fractional composition Distillation method Range ASTM D 5236-25","technique_en":"Distillation method","test_object_en":"Crude oil – distillation residue according to ASTM D 2892","parameters_zh":[{"name":"范围","range":"(380 – 565) °C"}],"search_zh":"馏程组成 蒸馏法 范围 ASTM D 5236-25","technique_zh":"蒸馏法","methodology_zh":"馏程组成"},{"_id":"6a836fb9af14b9c0e7b1ebab","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe olej napędowy, olej opałowy lekki, olej opałowy ciężki, Inne przetwory naftowe: olej popirolityczny, Ropa naftowa","methodology":"Temperatura płynięcia","parameters":[{"name":"[10","range":"(-50)] °C"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Temperatura płynięcia\n[10 (-50)] °C\nMetoda optyczna","reference":"PN-EN ISO 3016:2019-06 | ASTM D 97-17b(2022)","norm_bases":["PN-EN ISO 3016:2019-06","ASTM D 97-17b(2022)"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe olej napędowy, olej opałowy lekki, olej opałowy ciężki, Inne przetwory naftowe: olej popirolityczny, Ropa naftowa Temperatura płynięcia\n[10 (-50)] °C\nMetoda optyczna PN-EN ISO 3016:2019-06 | ASTM D 97-17b(2022) Paliwa ciekle olej napedowy, olej opalowy lekki, olej opalowy ciezki, Inne przetwory naftowe: olej popirolityczny, Ropa naftowa Temperatura plyniecia\n[10 (-50)] °C\nMetoda optyczna PN-EN ISO 3016:2019-06 | ASTM D 97-17b(2022)","categories":["petro"],"row_index":148,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Pour point","parameters_en":[{"name":"[10","range":"(-50)] °C"}],"search_en":"Liquid fuels diesel fuel, light heating oil, heavy heating oil, Other petroleum products: pyrolysis oil, Crude oil Pour point Optical method [10 PN-EN ISO 3016:2019-06 | ASTM D 97-17b(2022)","technique_en":"Optical method","test_object_en":"Liquid fuels diesel fuel, light heating oil, heavy heating oil, Other petroleum products: pyrolysis oil, Crude oil","search_zh":"倾点 光学法 PN-EN ISO 3016:2019-06 | ASTM D 97-17b(2022)","technique_zh":"光学法","methodology_zh":"倾点"},{"_id":"6a836fb9af14b9c0e7b1ebac","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, olej opałowy ciężki, Inne przetwory naftowe: olej popirolityczny, pozostałość próżniowa (gudron), Ropa naftowa","methodology":"Lepkość kinematyczna w temp. 20 °C, 40 °C, 50 °C, 80 °C i 100 °C","parameters":[{"name":"Zakres","range":"(1,000 – 150,0) mm2/s"}],"technique":"Metoda kapilarna","techniques":["Metoda kapilarna"],"computed":[],"activity":"Lepkość kinematyczna w temp. 20 °C, 40 °C, 50 °C, 80 °C i 100 °C\nZakres (1,000 – 150,0) mm2/s\nMetoda kapilarna","reference":"PN-EN ISO 3104:2024-01 | ASTM D 445-24","norm_bases":["PN-EN ISO 3104:2024-01","ASTM D 445-24"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, olej opałowy ciężki, Inne przetwory naftowe: olej popirolityczny, pozostałość próżniowa (gudron), Ropa naftowa Lepkość kinematyczna w temp. 20 °C, 40 °C, 50 °C, 80 °C i 100 °C\nZakres (1,000 – 150,0) mm2/s\nMetoda kapilarna PN-EN ISO 3104:2024-01 | ASTM D 445-24 Paliwa ciekle: olej napedowy, olej opalowy lekki, olej opalowy ciezki, Inne przetwory naftowe: olej popirolityczny, pozostalosc prozniowa (gudron), Ropa naftowa Lepkosc kinematyczna w temp. 20 °C, 40 °C, 50 °C, 80 °C i 100 °C\nZakres (1,000 – 150,0) mm2/s\nMetoda kapilarna PN-EN ISO 3104:2024-01 | ASTM D 445-24","categories":["petro"],"row_index":149,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kinematic viscosity at 20 °C, 40 °C, 50 °C, 80 °C and 100 °C","parameters_en":[{"name":"Range","range":"(1,000 – 150,0) mm2/s"}],"search_en":"Liquid fuels: diesel fuel, light heating oil, heavy heating oil, Other petroleum products: pyrolysis oil, vacuum residue (tar), Crude oil Kinematic viscosity at 20 °C, 40 °C, 50 °C, 80 °C and 100 °C Capillary method Range PN-EN ISO 3104:2024-01 | ASTM D 445-24","technique_en":"Capillary method","test_object_en":"Liquid fuels: diesel fuel, light heating oil, heavy heating oil, Other petroleum products: pyrolysis oil, vacuum residue (tar), Crude oil","parameters_zh":[{"name":"范围","range":"(1,000 – 150,0) mm2/s"}],"search_zh":"毛细管法 范围 PN-EN ISO 3104:2024-01 | ASTM D 445-24","technique_zh":"毛细管法"},{"_id":"6a836fb9af14b9c0e7b1ebad","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, Inne przetwory naftowe: pozostałość próżniowa (gudron), frakcje i/lub produkty naftowe o temperaturze wrzenia 20°C - 550°C, Ropa naftowa","methodology":"Pozostałość po koksowaniu","parameters":[{"name":"Zakres","range":"(0,01 – 24) %(m/m)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Pozostałość po koksowaniu\nZakres (0,01 – 24) %(m/m)\nMetoda wagowa","reference":"PN-ISO 6615:2012","norm_bases":["PN-ISO 6615:2012"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, Inne przetwory naftowe: pozostałość próżniowa (gudron), frakcje i/lub produkty naftowe o temperaturze wrzenia 20°C - 550°C, Ropa naftowa Pozostałość po koksowaniu\nZakres (0,01 – 24) %(m/m)\nMetoda wagowa PN-ISO 6615:2012 Paliwa ciekle: olej napedowy, Inne przetwory naftowe: pozostalosc prozniowa (gudron), frakcje i/lub produkty naftowe o temperaturze wrzenia 20°C - 550°C, Ropa naftowa Pozostalosc po koksowaniu\nZakres (0,01 – 24) %(m/m)\nMetoda wagowa PN-ISO 6615:2012","categories":["petro"],"row_index":150,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Carbon residue","parameters_en":[{"name":"Range","range":"(0,01 – 24) %(m/m)"}],"search_en":"Liquid fuels: diesel fuel, Other petroleum products: vacuum residue (tar), petroleum fractions and/or products with a boiling temperature 20°C - 550°C, Crude oil Carbon residue Gravimetric method Range PN-ISO 6615:2012","technique_en":"Gravimetric method","test_object_en":"Liquid fuels: diesel fuel, Other petroleum products: vacuum residue (tar), petroleum fractions and/or products with a boiling temperature 20°C - 550°C, Crude oil","parameters_zh":[{"name":"范围","range":"(0,01 – 24) %(m/m)"}],"search_zh":"残炭 重量法 范围 PN-ISO 6615:2012","technique_zh":"重量法","methodology_zh":"残炭"},{"_id":"6a836fb9af14b9c0e7b1ebae","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, Inne przetwory naftowe: pozostałość próżniowa (gudron), Ropa naftowa","methodology":"Zawartość siarki całkowitej","parameters":[{"name":"Zakres","range":"(0,0150 – 2,00) %(m/m)"}],"technique":"Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii","techniques":["Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii"],"computed":[],"activity":"Zawartość siarki całkowitej\nZakres (0,0150 – 2,00) %(m/m)\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii","reference":"ASTM D 4294-24","norm_bases":["ASTM D 4294-24"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, Inne przetwory naftowe: pozostałość próżniowa (gudron), Ropa naftowa Zawartość siarki całkowitej\nZakres (0,0150 – 2,00) %(m/m)\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii ASTM D 4294-24 Paliwa ciekle: olej napedowy, olej opalowy lekki, Inne przetwory naftowe: pozostalosc prozniowa (gudron), Ropa naftowa Zawartosc siarki calkowitej\nZakres (0,0150 – 2,00) %(m/m)\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersja energii ASTM D 4294-24","categories":["petro"],"row_index":151,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total sulfur content","parameters_en":[{"name":"Range","range":"(0,0150 – 2,00) %(m/m)"}],"search_en":"Liquid fuels: diesel fuel, light heating oil, Other petroleum products: vacuum residue (tar), Crude oil Total sulfur content Energy-dispersive X-ray fluorescence spectrometry Range ASTM D 4294-24","technique_en":"Energy-dispersive X-ray fluorescence spectrometry","test_object_en":"Liquid fuels: diesel fuel, light heating oil, Other petroleum products: vacuum residue (tar), Crude oil","methodology_zh":"全硫含量","parameters_zh":[{"name":"范围","range":"(0,0150 – 2,00) %(m/m)"}],"search_zh":"全硫含量 能量色散X射线荧光光谱法 范围 ASTM D 4294-24","technique_zh":"能量色散X射线荧光光谱法"},{"_id":"6a836fb9af14b9c0e7b1ebaf","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej opałowy ciężki, Inne przetwory naftowe: olej popirolityczny, Ropa naftowa","methodology":"Zawartość zanieczyszczeń","parameters":[{"name":"Zakres","range":"(0,01 – 0,40) %(m/m)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość zanieczyszczeń\nZakres (0,01 – 0,40) %(m/m)\nMetoda wagowa","reference":"PN-EN ISO 3735:2001 | ASTM D 473-22","norm_bases":["PN-EN ISO 3735:2001","ASTM D 473-22"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej opałowy ciężki, Inne przetwory naftowe: olej popirolityczny, Ropa naftowa Zawartość zanieczyszczeń\nZakres (0,01 – 0,40) %(m/m)\nMetoda wagowa PN-EN ISO 3735:2001 | ASTM D 473-22 Paliwa ciekle: olej opalowy ciezki, Inne przetwory naftowe: olej popirolityczny, Ropa naftowa Zawartosc zanieczyszczen\nZakres (0,01 – 0,40) %(m/m)\nMetoda wagowa PN-EN ISO 3735:2001 | ASTM D 473-22","categories":["petro"],"row_index":152,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Impurity content","parameters_en":[{"name":"Range","range":"(0,01 – 0,40) %(m/m)"}],"search_en":"Liquid fuels: heavy heating oil, Other petroleum products: pyrolysis oil, Crude oil Impurity content Gravimetric method Range PN-EN ISO 3735:2001 | ASTM D 473-22","technique_en":"Gravimetric method","test_object_en":"Liquid fuels: heavy heating oil, Other petroleum products: pyrolysis oil, Crude oil","parameters_zh":[{"name":"范围","range":"(0,01 – 0,40) %(m/m)"}],"search_zh":"杂质含量 重量法 范围 PN-EN ISO 3735:2001 | ASTM D 473-22","technique_zh":"重量法","methodology_zh":"杂质含量"},{"_id":"6a836fb9af14b9c0e7b1ebb0","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej opałowy ciężki, Inne przetwory naftowe: olej popirolityczny, pozostałość próżniowa (gudron), frakcje i/lub produkty naftowe o temperaturze wrzenia 80°C - 550°C, asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe","methodology":"Temperatura zapłonu","parameters":[{"name":"Zakres","range":"(90 – 380) oC"}],"technique":"Metoda otwartego tygla Clevelanda","techniques":["Metoda otwartego tygla Clevelanda"],"computed":[],"activity":"Temperatura zapłonu\nZakres (90 – 380) oC\nMetoda otwartego tygla Clevelanda","reference":"PN-EN ISO 2592:2017-10","norm_bases":["PN-EN ISO 2592:2017-10"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej opałowy ciężki, Inne przetwory naftowe: olej popirolityczny, pozostałość próżniowa (gudron), frakcje i/lub produkty naftowe o temperaturze wrzenia 80°C - 550°C, asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe Temperatura zapłonu\nZakres (90 – 380) oC\nMetoda otwartego tygla Clevelanda PN-EN ISO 2592:2017-10 Paliwa ciekle: olej opalowy ciezki, Inne przetwory naftowe: olej popirolityczny, pozostalosc prozniowa (gudron), frakcje i/lub produkty naftowe o temperaturze wrzenia 80°C - 550°C, asfalty drogowe, asfalty przemyslowe i wyroby asfaltowe Temperatura zaplonu\nZakres (90 – 380) oC\nMetoda otwartego tygla Clevelanda PN-EN ISO 2592:2017-10","categories":["petro"],"row_index":153,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Flash point","parameters_en":[{"name":"Range","range":"(90 – 380) oC"}],"search_en":"Liquid fuels: heavy heating oil, Other petroleum products: pyrolysis oil, vacuum residue (tar), petroleum fractions and/or products with a boiling temperature 80°C - 550°C, road bitumens, industrial bitumens and bituminous products Flash point Cleveland open cup method Range PN-EN ISO 2592:2017-10","technique_en":"Cleveland open cup method","test_object_en":"Liquid fuels: heavy heating oil, Other petroleum products: pyrolysis oil, vacuum residue (tar), petroleum fractions and/or products with a boiling temperature 80°C - 550°C, road bitumens, industrial bitumens and bituminous products","parameters_zh":[{"name":"范围","range":"(90 – 380) oC"}],"search_zh":"闪点 克利夫兰开口杯法 范围 PN-EN ISO 2592:2017-10","methodology_zh":"闪点","technique_zh":"克利夫兰开口杯法"},{"_id":"6a836fb9af14b9c0e7b1ebb1","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, biopaliwa ciekłe: olej napędowy z FAME, estry metylowe kwasów tłuszczowych (FAME), olej żeglugowy","methodology":"Zawartość siarki","parameters":[{"name":"Zakres","range":"(3,0 – 500) mg/kg"}],"technique":"Metoda fluorescencji w nadfiolecie","techniques":["Metoda fluorescencji w nadfiolecie"],"computed":[],"activity":"Zawartość siarki\nZakres (3,0 – 500) mg/kg\nMetoda fluorescencji w nadfiolecie","reference":"PN-EN ISO 20846:2020-03","norm_bases":["PN-EN ISO 20846:2020-03"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, biopaliwa ciekłe: olej napędowy z FAME, estry metylowe kwasów tłuszczowych (FAME), olej żeglugowy Zawartość siarki\nZakres (3,0 – 500) mg/kg\nMetoda fluorescencji w nadfiolecie PN-EN ISO 20846:2020-03 Paliwa ciekle: olej napedowy, olej opalowy lekki, biopaliwa ciekle: olej napedowy z FAME, estry metylowe kwasow tluszczowych (FAME), olej zeglugowy Zawartosc siarki\nZakres (3,0 – 500) mg/kg\nMetoda fluorescencji w nadfiolecie PN-EN ISO 20846:2020-03","categories":["petro"],"row_index":154,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfur content","parameters_en":[{"name":"Range","range":"(3,0 – 500) mg/kg"}],"search_en":"Liquid fuels: diesel fuel, light heating oil, liquid biofuels: diesel fuel with FAME, fatty acid methyl esters (FAME), marine oil Sulfur content Ultraviolet fluorescence method Range PN-EN ISO 20846:2020-03","technique_en":"Ultraviolet fluorescence method","test_object_en":"Liquid fuels: diesel fuel, light heating oil, liquid biofuels: diesel fuel with FAME, fatty acid methyl esters (FAME), marine oil","parameters_zh":[{"name":"范围","range":"(3,0 – 500) mg/kg"}],"search_zh":"硫含量 紫外荧光法 范围 PN-EN ISO 20846:2020-03","methodology_zh":"硫含量","technique_zh":"紫外荧光法"},{"_id":"6a836fb9af14b9c0e7b1ebb2","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, olej opałowy ciężki, biopaliwa ciekłe: olej napędowy z FAME, estry metylowe kwasów tłuszczowych (FAME), Inne przetwory naftowe: pozostałość próżniowa (gudron), frakcje i/lub produkty naftowe o temperaturze wrzenia 20°C - 550°C, Ropa naftowa","methodology":"Pozostałość po koksowaniu","parameters":[{"name":"Zakres","range":"(0,01 – 24,00) %(m/m)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Pozostałość po koksowaniu\nZakres (0,01 – 24,00) %(m/m)\nMetoda wagowa","reference":"PN-EN ISO 10370:2014-12","norm_bases":["PN-EN ISO 10370:2014-12"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, olej opałowy ciężki, biopaliwa ciekłe: olej napędowy z FAME, estry metylowe kwasów tłuszczowych (FAME), Inne przetwory naftowe: pozostałość próżniowa (gudron), frakcje i/lub produkty naftowe o temperaturze wrzenia 20°C - 550°C, Ropa naftowa Pozostałość po koksowaniu\nZakres (0,01 – 24,00) %(m/m)\nMetoda wagowa PN-EN ISO 10370:2014-12 Paliwa ciekle: olej napedowy, olej opalowy lekki, olej opalowy ciezki, biopaliwa ciekle: olej napedowy z FAME, estry metylowe kwasow tluszczowych (FAME), Inne przetwory naftowe: pozostalosc prozniowa (gudron), frakcje i/lub produkty naftowe o temperaturze wrzenia 20°C - 550°C, Ropa naftowa Pozostalosc po koksowaniu\nZakres (0,01 – 24,00) %(m/m)\nMetoda wagowa PN-EN ISO 10370:2014-12","categories":["petro"],"row_index":155,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Carbon residue","parameters_en":[{"name":"Range","range":"(0,01 – 24,00) %(m/m)"}],"search_en":"Liquid fuels: diesel fuel, light heating oil, heavy heating oil, liquid biofuels: diesel fuel with FAME, fatty acid methyl esters (FAME), Other petroleum products: vacuum residue (tar), petroleum fractions and/or products with a boiling temperature 20°C - 550°C, Crude oil Carbon residue Gravimetric method Range PN-EN ISO 10370:2014-12","technique_en":"Gravimetric method","test_object_en":"Liquid fuels: diesel fuel, light heating oil, heavy heating oil, liquid biofuels: diesel fuel with FAME, fatty acid methyl esters (FAME), Other petroleum products: vacuum residue (tar), petroleum fractions and/or products with a boiling temperature 20°C - 550°C, Crude oil","parameters_zh":[{"name":"范围","range":"(0,01 – 24,00) %(m/m)"}],"search_zh":"残炭 重量法 范围 PN-EN ISO 10370:2014-12","technique_zh":"重量法","methodology_zh":"残炭"},{"_id":"6a836fb9af14b9c0e7b1ebb3","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, olej opałowy ciężki, biopaliwa ciekłe: olej napędowy z FAME, Inne przetwory naftowe: olej popirolityczny, pozostałość próżniowa (gudron), Ropa naftowa","methodology":"Pozostałość po spopieleniu","parameters":[{"name":"Zakres","range":"(0,001 – 0,180) %(m/m)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Pozostałość po spopieleniu\nZakres (0,001 – 0,180) %(m/m)\nMetoda wagowa","reference":"PN-EN ISO 6245:2008","norm_bases":["PN-EN ISO 6245:2008"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, olej opałowy ciężki, biopaliwa ciekłe: olej napędowy z FAME, Inne przetwory naftowe: olej popirolityczny, pozostałość próżniowa (gudron), Ropa naftowa Pozostałość po spopieleniu\nZakres (0,001 – 0,180) %(m/m)\nMetoda wagowa PN-EN ISO 6245:2008 Paliwa ciekle: olej napedowy, olej opalowy lekki, olej opalowy ciezki, biopaliwa ciekle: olej napedowy z FAME, Inne przetwory naftowe: olej popirolityczny, pozostalosc prozniowa (gudron), Ropa naftowa Pozostalosc po spopieleniu\nZakres (0,001 – 0,180) %(m/m)\nMetoda wagowa PN-EN ISO 6245:2008","categories":["petro"],"row_index":156,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Residue after incineration","parameters_en":[{"name":"Range","range":"(0,001 – 0,180) %(m/m)"}],"search_en":"Liquid fuels: diesel fuel, light heating oil, heavy heating oil, liquid biofuels: diesel fuel with FAME, Other petroleum products: pyrolysis oil, vacuum residue (tar), Crude oil Residue after incineration Gravimetric method Range PN-EN ISO 6245:2008","technique_en":"Gravimetric method","test_object_en":"Liquid fuels: diesel fuel, light heating oil, heavy heating oil, liquid biofuels: diesel fuel with FAME, Other petroleum products: pyrolysis oil, vacuum residue (tar), Crude oil","parameters_zh":[{"name":"范围","range":"(0,001 – 0,180) %(m/m)"}],"search_zh":"灰化残渣 重量法 范围 PN-EN ISO 6245:2008","technique_zh":"重量法","methodology_zh":"灰化残渣"},{"_id":"6a836fb9af14b9c0e7b1ebb4","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, biopaliwa ciekłe: olej napędowy z FAME, estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość wody","parameters":[{"name":"Zakres","range":"(30 – 1000) mg/kg"},{"name":"Zakres","range":"(0,003 – 0,100) %(m/m)"}],"technique":"Metoda miareczkowania kulometrycznego","techniques":["Metoda miareczkowania kulometrycznego"],"computed":[],"activity":"Zawartość wody\nZakres:\nZakres (30 – 1000) mg/kg\nZakres (0,003 – 0,100) %(m/m)\nMetoda miareczkowania kulometrycznego","reference":"PN-EN ISO 12937:2005+Ap1:2021-11","norm_bases":["PN-EN ISO 12937:2005+Ap1:2021-11"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, biopaliwa ciekłe: olej napędowy z FAME, estry metylowe kwasów tłuszczowych (FAME) Zawartość wody\nZakres:\nZakres (30 – 1000) mg/kg\nZakres (0,003 – 0,100) %(m/m)\nMetoda miareczkowania kulometrycznego PN-EN ISO 12937:2005+Ap1:2021-11 Paliwa ciekle: olej napedowy, olej opalowy lekki, biopaliwa ciekle: olej napedowy z FAME, estry metylowe kwasow tluszczowych (FAME) Zawartosc wody\nZakres:\nZakres (30 – 1000) mg/kg\nZakres (0,003 – 0,100) %(m/m)\nMetoda miareczkowania kulometrycznego PN-EN ISO 12937:2005+Ap1:2021-11","categories":["petro","water"],"row_index":157,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water content","parameters_en":[{"name":"Range","range":"(30 – 1000) mg/kg"},{"name":"Range","range":"(0,003 – 0,100) %(m/m)"}],"search_en":"Liquid fuels: diesel fuel, light fuel oil, liquid biofuels: diesel fuel with FAME, fatty acid methyl esters (FAME) Water content Coulometric titration method Range Range PN-EN ISO 12937:2005+Ap1:2021-11","technique_en":"Coulometric titration method","test_object_en":"Liquid fuels: diesel fuel, light fuel oil, liquid biofuels: diesel fuel with FAME, fatty acid methyl esters (FAME)","methodology_zh":"水分含量","parameters_zh":[{"name":"范围","range":"(30 – 1000) mg/kg"},{"name":"范围","range":"(0,003 – 0,100) %(m/m)"}],"search_zh":"液体燃料：柴油、轻质燃料油；液体生物燃料：含 FAME 的柴油、脂肪酸甲酯（FAME） 水分含量 库仑滴定法 范围 范围 PN-EN ISO 12937:2005+Ap1:2021-11","technique_zh":"库仑滴定法","test_object_zh":"液体燃料：柴油、轻质燃料油；液体生物燃料：含 FAME 的柴油、脂肪酸甲酯（FAME）"},{"_id":"6a836fb9af14b9c0e7b1ebb5","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, biopaliwa ciekłe: olej napędowy z FAME, estry metylowe kwasów tłuszczowych (FAME)","methodology":"Temperatura mętnienia","parameters":[{"name":"[10","range":"(- 41)] oC"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Temperatura mętnienia\n[10 (- 41)] oC\nMetoda wizualna","reference":"PN-EN ISO 3015:2019-06","norm_bases":["PN-EN ISO 3015:2019-06"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, biopaliwa ciekłe: olej napędowy z FAME, estry metylowe kwasów tłuszczowych (FAME) Temperatura mętnienia\n[10 (- 41)] oC\nMetoda wizualna PN-EN ISO 3015:2019-06 Paliwa ciekle: olej napedowy, olej opalowy lekki, biopaliwa ciekle: olej napedowy z FAME, estry metylowe kwasow tluszczowych (FAME) Temperatura metnienia\n[10 (- 41)] oC\nMetoda wizualna PN-EN ISO 3015:2019-06","categories":["petro"],"row_index":158,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Cloud point","parameters_en":[{"name":"[10","range":"(- 41)] oC"}],"search_en":"Liquid fuels: diesel fuel, light fuel oil, liquid biofuels: diesel fuel with FAME, fatty acid methyl esters (FAME) Cloud point Visual method [10 PN-EN ISO 3015:2019-06","technique_en":"Visual method","test_object_en":"Liquid fuels: diesel fuel, light fuel oil, liquid biofuels: diesel fuel with FAME, fatty acid methyl esters (FAME)","search_zh":"液体燃料：柴油、轻质燃料油；液体生物燃料：含 FAME 的柴油、脂肪酸甲酯（FAME） 浊点 目视法 PN-EN ISO 3015:2019-06","technique_zh":"目视法","methodology_zh":"浊点","test_object_zh":"液体燃料：柴油、轻质燃料油；液体生物燃料：含 FAME 的柴油、脂肪酸甲酯（FAME）"},{"_id":"6a836fb9af14b9c0e7b1ebb6","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, biopaliwa ciekłe: olej napędowy z FAME, estry metylowe kwasów tłuszczowych (FAME)","methodology":"Działanie korodujące na miedź","parameters":[{"name":"Zakres","range":"1a – 4c (skala)"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Działanie korodujące na miedź\nZakres 1a – 4c (skala)\nMetoda wizualna","reference":"PN-EN ISO 2160:2004","norm_bases":["PN-EN ISO 2160:2004"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, biopaliwa ciekłe: olej napędowy z FAME, estry metylowe kwasów tłuszczowych (FAME) Działanie korodujące na miedź\nZakres 1a – 4c (skala)\nMetoda wizualna PN-EN ISO 2160:2004 Paliwa ciekle: olej napedowy, olej opalowy lekki, biopaliwa ciekle: olej napedowy z FAME, estry metylowe kwasow tluszczowych (FAME) Dzialanie korodujace na miedz\nZakres 1a – 4c (skala)\nMetoda wizualna PN-EN ISO 2160:2004","categories":["petro","materials"],"row_index":159,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Copper strip corrosion","parameters_en":[{"name":"Range","range":"1a – 4c (skala)"}],"search_en":"Liquid fuels: diesel fuel, light fuel oil, liquid biofuels: diesel fuel with FAME, fatty acid methyl esters (FAME) Copper strip corrosion Visual method Range PN-EN ISO 2160:2004","technique_en":"Visual method","test_object_en":"Liquid fuels: diesel fuel, light fuel oil, liquid biofuels: diesel fuel with FAME, fatty acid methyl esters (FAME)","parameters_zh":[{"name":"范围","range":"1a – 4c (skala)"}],"search_zh":"液体燃料：柴油、轻质燃料油；液体生物燃料：含 FAME 的柴油、脂肪酸甲酯（FAME） 铜片腐蚀 目视法 范围 PN-EN ISO 2160:2004","technique_zh":"目视法","methodology_zh":"铜片腐蚀","test_object_zh":"液体燃料：柴油、轻质燃料油；液体生物燃料：含 FAME 的柴油、脂肪酸甲酯（FAME）"},{"_id":"6a836fb9af14b9c0e7b1ebb7","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, biopaliwa ciekłe: olej napędowy z FAME, estry metylowe kwasów tłuszczowych (FAME)","methodology":"Temperatura zablokowania zimnego filtru","parameters":[{"name":"[5","range":"(- 45)] oC"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Temperatura zablokowania zimnego filtru\n[5 (- 45)] oC\nMetoda optyczna","reference":"PN-EN 116:2015-09","norm_bases":["PN-EN 116:2015-09"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, biopaliwa ciekłe: olej napędowy z FAME, estry metylowe kwasów tłuszczowych (FAME) Temperatura zablokowania zimnego filtru\n[5 (- 45)] oC\nMetoda optyczna PN-EN 116:2015-09 Paliwa ciekle: olej napedowy, olej opalowy lekki, biopaliwa ciekle: olej napedowy z FAME, estry metylowe kwasow tluszczowych (FAME) Temperatura zablokowania zimnego filtru\n[5 (- 45)] oC\nMetoda optyczna PN-EN 116:2015-09","categories":["petro"],"row_index":160,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Cold filter plugging point","parameters_en":[{"name":"[5","range":"(- 45)] oC"}],"search_en":"Liquid fuels: diesel fuel, light fuel oil, liquid biofuels: diesel fuel with FAME, fatty acid methyl esters (FAME) Cold filter plugging point Optical method [5 PN-EN 116:2015-09","technique_en":"Optical method","test_object_en":"Liquid fuels: diesel fuel, light fuel oil, liquid biofuels: diesel fuel with FAME, fatty acid methyl esters (FAME)","search_zh":"液体燃料：柴油、轻质燃料油；液体生物燃料：含 FAME 的柴油、脂肪酸甲酯（FAME） 冷滤点 光学法 PN-EN 116:2015-09","technique_zh":"光学法","methodology_zh":"冷滤点","test_object_zh":"液体燃料：柴油、轻质燃料油；液体生物燃料：含 FAME 的柴油、脂肪酸甲酯（FAME）"},{"_id":"6a836fb9af14b9c0e7b1ebb8","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, biopaliwa ciekłe: olej napędowy z FAME","methodology":"Zawartość zanieczyszczeń","parameters":[{"name":"Zakres","range":"(12,0 – 26,0) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość zanieczyszczeń\nZakres (12,0 – 26,0) mg/kg\nMetoda wagowa","reference":"PN-EN 12662-1:2024-11","norm_bases":["PN-EN 12662-1:2024-11"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, biopaliwa ciekłe: olej napędowy z FAME Zawartość zanieczyszczeń\nZakres (12,0 – 26,0) mg/kg\nMetoda wagowa PN-EN 12662-1:2024-11 Paliwa ciekle: olej napedowy, olej opalowy lekki, biopaliwa ciekle: olej napedowy z FAME Zawartosc zanieczyszczen\nZakres (12,0 – 26,0) mg/kg\nMetoda wagowa PN-EN 12662-1:2024-11","categories":["petro"],"row_index":161,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Impurity content","parameters_en":[{"name":"Range","range":"(12,0 – 26,0) mg/kg"}],"search_en":"Liquid fuels: diesel fuel, light fuel oil, liquid biofuels: diesel fuel with FAME Impurity content Gravimetric method Range PN-EN 12662-1:2024-11","technique_en":"Gravimetric method","test_object_en":"Liquid fuels: diesel fuel, light fuel oil, liquid biofuels: diesel fuel with FAME","parameters_zh":[{"name":"范围","range":"(12,0 – 26,0) mg/kg"}],"search_zh":"杂质含量 重量法 范围 PN-EN 12662-1:2024-11","technique_zh":"重量法","methodology_zh":"杂质含量"},{"_id":"6a836fb9af14b9c0e7b1ebb9","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość zanieczyszczeń","parameters":[{"name":"Zakres","range":"(5,0 – 27,0) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość zanieczyszczeń\nZakres (5,0 – 27,0) mg/kg\nMetoda wagowa","reference":"PN-EN 12662-2:2024-11","norm_bases":["PN-EN 12662-2:2024-11"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Zawartość zanieczyszczeń\nZakres (5,0 – 27,0) mg/kg\nMetoda wagowa PN-EN 12662-2:2024-11 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Zawartosc zanieczyszczen\nZakres (5,0 – 27,0) mg/kg\nMetoda wagowa PN-EN 12662-2:2024-11","categories":["petro"],"row_index":162,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Impurity content","parameters_en":[{"name":"Range","range":"(5,0 – 27,0) mg/kg"}],"search_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME) Impurity content Gravimetric method Range PN-EN 12662-2:2024-11","technique_en":"Gravimetric method","test_object_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME)","parameters_zh":[{"name":"范围","range":"(5,0 – 27,0) mg/kg"}],"search_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME） 杂质含量 重量法 范围 PN-EN 12662-2:2024-11","technique_zh":"重量法","methodology_zh":"杂质含量","test_object_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME）"},{"_id":"6a836fb9af14b9c0e7b1ebba","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej opałowy lekki, olej opałowy ciężki, Inne przetwory naftowe: pozostałość próżniowa (gudron)","methodology":"Ciepło spalania","parameters":[{"name":"Zakres","range":"(26 500 – 46 300) kJ/kg"},{"name":"Wartość opałowa (z obliczeń)"}],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna"],"computed":[],"activity":"Ciepło spalania\nZakres:\nZakres (26 500 – 46 300) kJ/kg\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna","reference":"PN-C-04062:2018-05","norm_bases":["PN-C-04062:2018-05"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej opałowy lekki, olej opałowy ciężki, Inne przetwory naftowe: pozostałość próżniowa (gudron) Ciepło spalania\nZakres:\nZakres (26 500 – 46 300) kJ/kg\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna PN-C-04062:2018-05 Paliwa ciekle: olej opalowy lekki, olej opalowy ciezki, Inne przetwory naftowe: pozostalosc prozniowa (gudron) Cieplo spalania\nZakres:\nZakres (26 500 – 46 300) kJ/kg\nWartosc opalowa (z obliczen)\nMetoda kalorymetryczna PN-C-04062:2018-05","categories":["petro"],"row_index":163,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gross calorific value","parameters_en":[{"name":"Range","range":"(26 500 – 46 300) kJ/kg"},{"name":"Net calorific value (calculated)"}],"search_en":"Liquid fuels: light heating oil, heavy heating oil, Other petroleum products: vacuum residue (tar) Gross calorific value Calorimetric method Range Net calorific value (calculated) PN-C-04062:2018-05","technique_en":"Calorimetric method","test_object_en":"Liquid fuels: light heating oil, heavy heating oil, Other petroleum products: vacuum residue (tar)","methodology_zh":"高位发热量","parameters_zh":[{"name":"范围","range":"(26 500 – 46 300) kJ/kg"},{"name":"低位发热量（计算值）"}],"search_zh":"高位发热量 量热法 范围 低位发热量（计算值） PN-C-04062:2018-05","technique_zh":"量热法"},{"_id":"6a836fb9af14b9c0e7b1ebbb","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, biopaliwa ciekłe: olej napędowy z FAME, Inne przetwory naftowe: pozostałość próżniowa (gudron)","methodology":"Gęstość","parameters":[{"name":"Zakres","range":"(600 – 1100) kg/m3"}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"computed":[],"activity":"Gęstość\nZakres (600 – 1100) kg/m3\nMetoda oscylacyjna","reference":"ASTM D 4052-22","norm_bases":["ASTM D 4052-22"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, biopaliwa ciekłe: olej napędowy z FAME, Inne przetwory naftowe: pozostałość próżniowa (gudron) Gęstość\nZakres (600 – 1100) kg/m3\nMetoda oscylacyjna ASTM D 4052-22 Paliwa ciekle: olej napedowy, olej opalowy lekki, biopaliwa ciekle: olej napedowy z FAME, Inne przetwory naftowe: pozostalosc prozniowa (gudron) Gestosc\nZakres (600 – 1100) kg/m3\nMetoda oscylacyjna ASTM D 4052-22","categories":["petro"],"row_index":164,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Density","parameters_en":[{"name":"Range","range":"(600 – 1100) kg/m3"}],"search_en":"Liquid fuels: diesel fuel, light heating oil, liquid biofuels: diesel fuel with FAME, Other petroleum products: vacuum residue (tar) Density Oscillation method Range ASTM D 4052-22","technique_en":"Oscillation method","test_object_en":"Liquid fuels: diesel fuel, light heating oil, liquid biofuels: diesel fuel with FAME, Other petroleum products: vacuum residue (tar)","methodology_zh":"密度","parameters_zh":[{"name":"范围","range":"(600 – 1100) kg/m3"}],"search_zh":"密度 振荡法 范围 ASTM D 4052-22","technique_zh":"振荡法"},{"_id":"6a836fb9af14b9c0e7b1ebbc","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, olej opałowy ciężki, Inne przetwory naftowe: pozostałość próżniowa (gudron)","methodology":"Zawartość węgla","parameters":[{"name":"Zakres","range":"(78 – 88) %(m/m)"}],"technique":"Metoda spektrometrii w zakresie podczerwieni IR","techniques":["Metoda spektrometrii w zakresie podczerwieni IR"],"computed":[],"activity":"Zawartość węgla\nZakres (78 – 88) %(m/m)\nMetoda spektrometrii w zakresie podczerwieni IR","reference":"ASTM D 5291-21 Metoda D","norm_bases":["ASTM D 5291-21 Metoda D"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, olej opałowy ciężki, Inne przetwory naftowe: pozostałość próżniowa (gudron) Zawartość węgla\nZakres (78 – 88) %(m/m)\nMetoda spektrometrii w zakresie podczerwieni IR ASTM D 5291-21 Metoda D Paliwa ciekle: olej napedowy, olej opalowy lekki, olej opalowy ciezki, Inne przetwory naftowe: pozostalosc prozniowa (gudron) Zawartosc wegla\nZakres (78 – 88) %(m/m)\nMetoda spektrometrii w zakresie podczerwieni IR ASTM D 5291-21 Metoda D","categories":["petro"],"row_index":165,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Carbon content","parameters_en":[{"name":"Range","range":"(78 – 88) %(m/m)"}],"search_en":"Liquid fuels: diesel fuel, light heating oil, heavy heating oil, Other petroleum products: vacuum residue (tar) Carbon content Spectrometry method in the infrared range IR Range ASTM D 5291-21 Metoda D","technique_en":"Spectrometry method in the infrared range IR","test_object_en":"Liquid fuels: diesel fuel, light heating oil, heavy heating oil, Other petroleum products: vacuum residue (tar)","parameters_zh":[{"name":"范围","range":"(78 – 88) %(m/m)"}],"search_zh":"碳含量 红外光谱法 IR 范围 ASTM D 5291-21 Metoda D","technique_zh":"红外光谱法 IR","methodology_zh":"碳含量"},{"_id":"6a836fb9af14b9c0e7b1ebbd","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki","methodology":"Korozja na trzpieniu stalowym","parameters":[],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Korozja na trzpieniu stalowym\nMetoda wizualna","reference":"ASTM D 665-24 | PN-ISO 7120:2011","norm_bases":["ASTM D 665-24","PN-ISO 7120:2011"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki Korozja na trzpieniu stalowym\nMetoda wizualna ASTM D 665-24 | PN-ISO 7120:2011 Paliwa ciekle: benzyna bezolowiowa, olej napedowy, olej opalowy lekki Korozja na trzpieniu stalowym\nMetoda wizualna ASTM D 665-24 | PN-ISO 7120:2011","categories":["petro","materials"],"row_index":166,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Corrosion on a steel rod","search_en":"Liquid fuels: unleaded petrol, diesel fuel, light fuel oil Corrosion on a steel rod Visual method ASTM D 665-24 | PN-ISO 7120:2011","technique_en":"Visual method","test_object_en":"Liquid fuels: unleaded petrol, diesel fuel, light fuel oil","search_zh":"液体燃料：无铅汽油、柴油、轻质燃料油 目视法 ASTM D 665-24 | PN-ISO 7120:2011","technique_zh":"目视法","test_object_zh":"液体燃料：无铅汽油、柴油、轻质燃料油"},{"_id":"6a836fb9af14b9c0e7b1ebbe","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej opałowy ciężki, Inne przetwory naftowe: olej popirolityczny, pozostałość próżniowa (gudron), frakcje i/lub produkty naftowe o temperaturze wrzenia 20°C - 550°C, asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe","methodology":"Zawartość wody","parameters":[{"name":"Zakres","range":"(0 – 25) %(v/v)"}],"technique":"Metoda destylacyjna","techniques":["Metoda destylacyjna"],"computed":[],"activity":"Zawartość wody\nZakres (0 – 25) %(v/v)\nMetoda destylacyjna","reference":"PN-ISO 3733:2008","norm_bases":["PN-ISO 3733:2008"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej opałowy ciężki, Inne przetwory naftowe: olej popirolityczny, pozostałość próżniowa (gudron), frakcje i/lub produkty naftowe o temperaturze wrzenia 20°C - 550°C, asfalty drogowe, asfalty przemysłowe i wyroby asfaltowe Zawartość wody\nZakres (0 – 25) %(v/v)\nMetoda destylacyjna PN-ISO 3733:2008 Paliwa ciekle: olej opalowy ciezki, Inne przetwory naftowe: olej popirolityczny, pozostalosc prozniowa (gudron), frakcje i/lub produkty naftowe o temperaturze wrzenia 20°C - 550°C, asfalty drogowe, asfalty przemyslowe i wyroby asfaltowe Zawartosc wody\nZakres (0 – 25) %(v/v)\nMetoda destylacyjna PN-ISO 3733:2008","categories":["petro","water"],"row_index":167,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water content","parameters_en":[{"name":"Range","range":"(0 – 25) %(v/v)"}],"search_en":"Liquid fuels: heavy heating oil, Other petroleum products: pyrolysis oil, vacuum residue (tar), petroleum fractions and/or products with a boiling temperature 20°C - 550°C, road bitumens, industrial bitumens and bituminous products Water content Distillation method Range PN-ISO 3733:2008","technique_en":"Distillation method","test_object_en":"Liquid fuels: heavy heating oil, Other petroleum products: pyrolysis oil, vacuum residue (tar), petroleum fractions and/or products with a boiling temperature 20°C - 550°C, road bitumens, industrial bitumens and bituminous products","methodology_zh":"水分含量","parameters_zh":[{"name":"范围","range":"(0 – 25) %(v/v)"}],"search_zh":"水分含量 蒸馏法 范围 PN-ISO 3733:2008","technique_zh":"蒸馏法"},{"_id":"6a836fb9af14b9c0e7b1ebbf","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: olej napędowy z FAME, estry metylowe kwasów tłuszczowych (FAME)","methodology":"Lepkość kinematyczna w temp. 40 oC","parameters":[{"name":"Zakres","range":"(1,000 – 150,0) mm2/s"}],"technique":"Metoda kapilarna","techniques":["Metoda kapilarna"],"computed":[],"activity":"Lepkość kinematyczna w temp. 40 oC\nZakres (1,000 – 150,0) mm2/s\nMetoda kapilarna","reference":"PN-EN ISO 3104:2024-01","norm_bases":["PN-EN ISO 3104:2024-01"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: olej napędowy z FAME, estry metylowe kwasów tłuszczowych (FAME) Lepkość kinematyczna w temp. 40 oC\nZakres (1,000 – 150,0) mm2/s\nMetoda kapilarna PN-EN ISO 3104:2024-01 Paliwa ciekle: biopaliwa ciekle: olej napedowy z FAME, estry metylowe kwasow tluszczowych (FAME) Lepkosc kinematyczna w temp. 40 oC\nZakres (1,000 – 150,0) mm2/s\nMetoda kapilarna PN-EN ISO 3104:2024-01","categories":["petro"],"row_index":168,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kinematic viscosity at 40 oC","parameters_en":[{"name":"Range","range":"(1,000 – 150,0) mm2/s"}],"search_en":"Liquid fuels: liquid biofuels: diesel fuel with FAME, fatty acid methyl esters (FAME) Kinematic viscosity at 40 oC Capillary method Range PN-EN ISO 3104:2024-01","technique_en":"Capillary method","test_object_en":"Liquid fuels: liquid biofuels: diesel fuel with FAME, fatty acid methyl esters (FAME)","parameters_zh":[{"name":"范围","range":"(1,000 – 150,0) mm2/s"}],"search_zh":"毛细管法 范围 PN-EN ISO 3104:2024-01","technique_zh":"毛细管法"},{"_id":"6a836fb9af14b9c0e7b1ebc0","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: olej napędowy z FAME, estry metylowe kwasów tłuszczowych (FAME)","methodology":"Stabilność oksydacyjna","parameters":[{"name":"Zakres","range":"(0,1 – 25,0) h"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Stabilność oksydacyjna\nZakres (0,1 – 25,0) h\nMetoda konduktometryczna","reference":"PN-EN 15751:2014-05","norm_bases":["PN-EN 15751:2014-05"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: olej napędowy z FAME, estry metylowe kwasów tłuszczowych (FAME) Stabilność oksydacyjna\nZakres (0,1 – 25,0) h\nMetoda konduktometryczna PN-EN 15751:2014-05 Paliwa ciekle: biopaliwa ciekle: olej napedowy z FAME, estry metylowe kwasow tluszczowych (FAME) Stabilnosc oksydacyjna\nZakres (0,1 – 25,0) h\nMetoda konduktometryczna PN-EN 15751:2014-05","categories":["petro"],"row_index":169,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Oxidation stability","parameters_en":[{"name":"Range","range":"(0,1 – 25,0) h"}],"search_en":"Liquid fuels: liquid biofuels: diesel fuel with FAME, fatty acid methyl esters (FAME) Oxidation stability Conductometric method Range PN-EN 15751:2014-05","technique_en":"Conductometric method","test_object_en":"Liquid fuels: liquid biofuels: diesel fuel with FAME, fatty acid methyl esters (FAME)","parameters_zh":[{"name":"范围","range":"(0,1 – 25,0) h"}],"search_zh":"氧化安定性 电导法 范围 PN-EN 15751:2014-05","technique_zh":"电导法","methodology_zh":"氧化安定性"},{"_id":"6a836fb9af14b9c0e7b1ebc1","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość popiołu siarczanowego","parameters":[{"name":"Zakres","range":"(0,005 – 0,25) %(m/m)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość popiołu siarczanowego\nZakres (0,005 – 0,25) %(m/m)\nMetoda wagowa","reference":"PN-ISO 3987:2014-05","norm_bases":["PN-ISO 3987:2014-05"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Zawartość popiołu siarczanowego\nZakres (0,005 – 0,25) %(m/m)\nMetoda wagowa PN-ISO 3987:2014-05 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Zawartosc popiolu siarczanowego\nZakres (0,005 – 0,25) %(m/m)\nMetoda wagowa PN-ISO 3987:2014-05","categories":["petro"],"row_index":170,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfated ash content","parameters_en":[{"name":"Range","range":"(0,005 – 0,25) %(m/m)"}],"search_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME) Sulfated ash content Gravimetric method Range PN-ISO 3987:2014-05","technique_en":"Gravimetric method","test_object_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME)","parameters_zh":[{"name":"范围","range":"(0,005 – 0,25) %(m/m)"}],"search_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME） 硫酸盐灰分含量 重量法 范围 PN-ISO 3987:2014-05","technique_zh":"重量法","test_object_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME）","methodology_zh":"硫酸盐灰分含量"},{"_id":"6a836fb9af14b9c0e7b1ebc2","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Stabilność oksydacyjna","parameters":[{"name":"Zakres","range":"(0,1 – 14,0) h"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Stabilność oksydacyjna\nZakres (0,1 – 14,0) h\nMetoda konduktometryczna","reference":"PN-EN 14112:2021-05","norm_bases":["PN-EN 14112:2021-05"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Stabilność oksydacyjna\nZakres (0,1 – 14,0) h\nMetoda konduktometryczna PN-EN 14112:2021-05 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Stabilnosc oksydacyjna\nZakres (0,1 – 14,0) h\nMetoda konduktometryczna PN-EN 14112:2021-05","categories":["petro"],"row_index":171,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Oxidation stability","parameters_en":[{"name":"Range","range":"(0,1 – 14,0) h"}],"search_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME) Oxidation stability Conductometric method Range PN-EN 14112:2021-05","technique_en":"Conductometric method","test_object_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME)","parameters_zh":[{"name":"范围","range":"(0,1 – 14,0) h"}],"search_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME） 氧化安定性 电导法 范围 PN-EN 14112:2021-05","technique_zh":"电导法","methodology_zh":"氧化安定性","test_object_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME）"},{"_id":"6a836fb9af14b9c0e7b1ebc3","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Skłonność do blokowania filtra po wychładzaniu","parameters":[{"name":"Zakres","range":"(50 – 720) s"}],"technique":"Metoda CSFT","techniques":["Metoda CSFT"],"computed":[],"activity":"Skłonność do blokowania filtra po wychładzaniu\nZakres (50 – 720) s\nMetoda CSFT","reference":"ASTM D 7501-22","norm_bases":["ASTM D 7501-22"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Skłonność do blokowania filtra po wychładzaniu\nZakres (50 – 720) s\nMetoda CSFT ASTM D 7501-22 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Sklonnosc do blokowania filtra po wychladzaniu\nZakres (50 – 720) s\nMetoda CSFT ASTM D 7501-22","categories":["petro"],"row_index":172,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Tendency to plug the filter after cooling","parameters_en":[{"name":"Range","range":"(50 – 720) s"}],"search_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME) Tendency to plug the filter after cooling CSFT method Range ASTM D 7501-22","technique_en":"CSFT method","test_object_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME)","parameters_zh":[{"name":"范围","range":"(50 – 720) s"}],"search_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME） 冷却后堵塞滤器的倾向 范围 ASTM D 7501-22","test_object_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME）","methodology_zh":"冷却后堵塞滤器的倾向"},{"_id":"6a836fb9af14b9c0e7b1ebc4","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość metali grupy I","parameters":[{"name":"Na","range":"(1 – 10) mg/kg"},{"name":"K","range":"(1 – 10) mg/kg"},{"name":"Suma (Na i K) mg/kg (z obliczeń)"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość metali grupy I\nZakres:\nNa (1 – 10) mg/kg\nK (1 – 10) mg/kg\nSuma (Na i K) mg/kg (z obliczeń)\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN 14538:2008","norm_bases":["PN-EN 14538:2008"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Zawartość metali grupy I\nZakres:\nNa (1 – 10) mg/kg\nK (1 – 10) mg/kg\nSuma (Na i K) mg/kg (z obliczeń)\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN 14538:2008 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Zawartosc metali grupy I\nZakres:\nNa (1 – 10) mg/kg\nK (1 – 10) mg/kg\nSuma (Na i K) mg/kg (z obliczen)\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN 14538:2008","categories":["materials","petro"],"row_index":173,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Group I metal content","parameters_en":[{"name":"Na","range":"(1 – 10) mg/kg"},{"name":"K","range":"(1 – 10) mg/kg"},{"name":"Sum of (Na and K) mg/kg (calculated)"}],"search_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME) Group I metal content Inductively coupled plasma optical emission spectrometry (ICP-OES) Na K Sum of (Na and K) mg/kg (calculated) PN-EN 14538:2008","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME)","search_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME） 电感耦合等离子体原子发射光谱法（ICP-OES） Na K PN-EN 14538:2008","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","parameters_zh":[{"name":"Na","range":"(1 – 10) mg/kg"},{"name":"K","range":"(1 – 10) mg/kg"},{"name":"Suma (Na i K) mg/kg (z obliczeń)"}],"test_object_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME）"},{"_id":"6a836fb9af14b9c0e7b1ebc5","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość metali grupy II","parameters":[{"name":"Ca","range":"(1 – 10) mg/kg"},{"name":"Mg","range":"(1,2 – 10) mg/kg"},{"name":"Suma (Ca i Mg) mg/kg (z obliczeń)"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość metali grupy II\nZakres:\nCa (1 – 10) mg/kg\nMg (1,2 – 10) mg/kg\nSuma (Ca i Mg) mg/kg (z obliczeń)\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN 14538:2008","norm_bases":["PN-EN 14538:2008"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Zawartość metali grupy II\nZakres:\nCa (1 – 10) mg/kg\nMg (1,2 – 10) mg/kg\nSuma (Ca i Mg) mg/kg (z obliczeń)\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN 14538:2008 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Zawartosc metali grupy II\nZakres:\nCa (1 – 10) mg/kg\nMg (1,2 – 10) mg/kg\nSuma (Ca i Mg) mg/kg (z obliczen)\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN 14538:2008","categories":["materials","petro"],"row_index":174,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Group II metal content","parameters_en":[{"name":"Ca","range":"(1 – 10) mg/kg"},{"name":"Mg","range":"(1,2 – 10) mg/kg"},{"name":"Sum of (Ca and Mg) mg/kg (calculated)"}],"search_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME) Group II metal content Inductively coupled plasma optical emission spectrometry (ICP-OES) Ca Mg Sum of (Ca and Mg) mg/kg (calculated) PN-EN 14538:2008","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME)","search_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME） 电感耦合等离子体原子发射光谱法（ICP-OES） Ca Mg PN-EN 14538:2008","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","parameters_zh":[{"name":"Ca","range":"(1 – 10) mg/kg"},{"name":"Mg","range":"(1,2 – 10) mg/kg"},{"name":"Suma (Ca i Mg) mg/kg (z obliczeń)"}],"test_object_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME）"},{"_id":"6a836fb9af14b9c0e7b1ebc6","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość fosforu","parameters":[{"name":"Zakres","range":"(4 – 20) mg/kg"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość fosforu\nZakres (4 – 20) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN 14107:2004","norm_bases":["PN-EN 14107:2004"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Zawartość fosforu\nZakres (4 – 20) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN 14107:2004 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Zawartosc fosforu\nZakres (4 – 20) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN 14107:2004","categories":["petro"],"row_index":175,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phosphorus content","parameters_en":[{"name":"Range","range":"(4 – 20) mg/kg"}],"search_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME) Phosphorus content Inductively coupled plasma optical emission spectrometry (ICP-OES) Range PN-EN 14107:2004","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME)","parameters_zh":[{"name":"范围","range":"(4 – 20) mg/kg"}],"search_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME） 磷含量 电感耦合等离子体原子发射光谱法（ICP-OES） 范围 PN-EN 14107:2004","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","methodology_zh":"磷含量","test_object_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME）"},{"_id":"6a836fb9af14b9c0e7b1ebc7","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy","methodology":"Zawartość manganu","parameters":[{"name":"Zakres","range":"(0,5 – 7,0) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość manganu\nZakres (0,5 – 7,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN 16576:2014-12+Ap1:2017-11","norm_bases":["PN-EN 16576:2014-12+Ap1:2017-11"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy Zawartość manganu\nZakres (0,5 – 7,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w indukcyjnie sprzężonej (ICP-OES) PN-EN 16576:2014-12+Ap1:2017-11 Paliwa ciekle: olej napedowy Zawartosc manganu\nZakres (0,5 – 7,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w indukcyjnie sprzezonej (ICP-OES) PN-EN 16576:2014-12+Ap1:2017-11","categories":["petro"],"row_index":176,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Manganese content","parameters_en":[{"name":"Range","range":"(0,5 – 7,0) mg/l"}],"search_en":"Liquid fuels: diesel fuel Manganese content Inductively coupled plasma atomic emission spectrometry (ICP-OES) Range PN-EN 16576:2014-12+Ap1:2017-11","technique_en":"Inductively coupled plasma atomic emission spectrometry (ICP-OES)","test_object_en":"Liquid fuels: diesel fuel","parameters_zh":[{"name":"范围","range":"(0,5 – 7,0) mg/l"}],"search_zh":"液体燃料：柴油 锰含量 范围 PN-EN 16576:2014-12+Ap1:2017-11","test_object_zh":"液体燃料：柴油","methodology_zh":"锰含量"},{"_id":"6a836fb9af14b9c0e7b1ebc8","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy","methodology":"Stabilność oksydacyjna","parameters":[{"name":"Zakres","range":"(5,0 – 50,0) h"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Stabilność oksydacyjna\nZakres (5,0 – 50,0) h\nMetoda konduktometryczna","reference":"PN-EN 15751:2014-05","norm_bases":["PN-EN 15751:2014-05"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy Stabilność oksydacyjna\nZakres (5,0 – 50,0) h\nMetoda konduktometryczna PN-EN 15751:2014-05 Paliwa ciekle: olej napedowy Stabilnosc oksydacyjna\nZakres (5,0 – 50,0) h\nMetoda konduktometryczna PN-EN 15751:2014-05","categories":["petro"],"row_index":177,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Oxidation stability","parameters_en":[{"name":"Range","range":"(5,0 – 50,0) h"}],"search_en":"Liquid fuels: diesel fuel Oxidation stability Conductometric method Range PN-EN 15751:2014-05","technique_en":"Conductometric method","test_object_en":"Liquid fuels: diesel fuel","parameters_zh":[{"name":"范围","range":"(5,0 – 50,0) h"}],"search_zh":"液体燃料：柴油 氧化安定性 电导法 范围 PN-EN 15751:2014-05","technique_zh":"电导法","test_object_zh":"液体燃料：柴油","methodology_zh":"氧化安定性"},{"_id":"6a836fb9af14b9c0e7b1ebc9","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, Inne przetwory naftowe: olej popirolityczny, pozostałość próżniowa (gudron), frakcje i/lub produkty naftowe o temperaturze wrzenia 50°C - 570°C","methodology":"Zawartość wody","parameters":[{"name":"Zakres","range":"(0,003 – 0,100) %(m/m)"}],"technique":"Metoda miareczkowania potencjometrycznego","techniques":["Metoda miareczkowania potencjometrycznego"],"computed":[],"activity":"Zawartość wody\nZakres (0,003 – 0,100) %(m/m)\nMetoda miareczkowania potencjometrycznego","reference":"PN-ISO 6296:2011","norm_bases":["PN-ISO 6296:2011"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, Inne przetwory naftowe: olej popirolityczny, pozostałość próżniowa (gudron), frakcje i/lub produkty naftowe o temperaturze wrzenia 50°C - 570°C Zawartość wody\nZakres (0,003 – 0,100) %(m/m)\nMetoda miareczkowania potencjometrycznego PN-ISO 6296:2011 Paliwa ciekle: olej napedowy, Inne przetwory naftowe: olej popirolityczny, pozostalosc prozniowa (gudron), frakcje i/lub produkty naftowe o temperaturze wrzenia 50°C - 570°C Zawartosc wody\nZakres (0,003 – 0,100) %(m/m)\nMetoda miareczkowania potencjometrycznego PN-ISO 6296:2011","categories":["petro","water"],"row_index":178,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water content","parameters_en":[{"name":"Range","range":"(0,003 – 0,100) %(m/m)"}],"search_en":"Liquid fuels: diesel fuel, Other petroleum products: pyrolysis oil, vacuum residue (tar), petroleum fractions and/or products with a boiling temperature 50°C - 570°C Water content Potentiometric titration method Range PN-ISO 6296:2011","technique_en":"Potentiometric titration method","test_object_en":"Liquid fuels: diesel fuel, Other petroleum products: pyrolysis oil, vacuum residue (tar), petroleum fractions and/or products with a boiling temperature 50°C - 570°C","methodology_zh":"水分含量","parameters_zh":[{"name":"范围","range":"(0,003 – 0,100) %(m/m)"}],"search_zh":"水分含量 电位滴定法 范围 PN-ISO 6296:2011","technique_zh":"电位滴定法"},{"_id":"6a836fb9af14b9c0e7b1ebca","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy ciężki, Inne przetwory naftowe: olej popirolityczny, pozostałość próżniowa (gudron), frakcje i/lub produkty naftowe o temperaturze wrzenia 20°C - 550°C","methodology":"Zawartość siarkowodoru","parameters":[{"name":"Zakres","range":"(0,10 – 48,0) mg/kg"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Zawartość siarkowodoru\nZakres (0,10 – 48,0) mg/kg\nMetoda elektrochemiczna","reference":"IP 570/15(2021)","norm_bases":["IP 570/15(2021)"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy ciężki, Inne przetwory naftowe: olej popirolityczny, pozostałość próżniowa (gudron), frakcje i/lub produkty naftowe o temperaturze wrzenia 20°C - 550°C Zawartość siarkowodoru\nZakres (0,10 – 48,0) mg/kg\nMetoda elektrochemiczna IP 570/15(2021) Paliwa ciekle: olej napedowy, olej opalowy ciezki, Inne przetwory naftowe: olej popirolityczny, pozostalosc prozniowa (gudron), frakcje i/lub produkty naftowe o temperaturze wrzenia 20°C - 550°C Zawartosc siarkowodoru\nZakres (0,10 – 48,0) mg/kg\nMetoda elektrochemiczna IP 570/15(2021)","categories":["petro"],"row_index":179,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrogen sulphide content","parameters_en":[{"name":"Range","range":"(0,10 – 48,0) mg/kg"}],"search_en":"Liquid fuels: diesel fuel, heavy heating oil, Other petroleum products: pyrolysis oil, vacuum residue (tar), petroleum fractions and/or products with a boiling temperature 20°C - 550°C Hydrogen sulphide content Electrochemical method Range IP 570/15(2021)","technique_en":"Electrochemical method","test_object_en":"Liquid fuels: diesel fuel, heavy heating oil, Other petroleum products: pyrolysis oil, vacuum residue (tar), petroleum fractions and/or products with a boiling temperature 20°C - 550°C","parameters_zh":[{"name":"范围","range":"(0,10 – 48,0) mg/kg"}],"search_zh":"硫化氢含量 电化学法 范围 IP 570/15(2021)","technique_zh":"电化学法","methodology_zh":"硫化氢含量"},{"_id":"6a836fb9af14b9c0e7b1ebcb","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej opałowy ciężki, Inne przetwory naftowe: pozostałości próżniowe","methodology":"Zawartość całkowitego osadu","parameters":[{"name":"Zakres","range":"(0,01 – 0,50) %(m/m)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość całkowitego osadu\nZakres (0,01 – 0,50) %(m/m)\nMetoda wagowa","reference":"PN-ISO 10307-1:2010 | ASTM D 4870-22","norm_bases":["PN-ISO 10307-1:2010","ASTM D 4870-22"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej opałowy ciężki, Inne przetwory naftowe: pozostałości próżniowe Zawartość całkowitego osadu\nZakres (0,01 – 0,50) %(m/m)\nMetoda wagowa PN-ISO 10307-1:2010 | ASTM D 4870-22 Paliwa ciekle: olej opalowy ciezki, Inne przetwory naftowe: pozostalosci prozniowe Zawartosc calkowitego osadu\nZakres (0,01 – 0,50) %(m/m)\nMetoda wagowa PN-ISO 10307-1:2010 | ASTM D 4870-22","categories":["petro","water"],"row_index":180,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total sediment content","parameters_en":[{"name":"Range","range":"(0,01 – 0,50) %(m/m)"}],"search_en":"Liquid fuels: heavy heating oil, Other petroleum products: vacuum residues Total sediment content Gravimetric method Range PN-ISO 10307-1:2010 | ASTM D 4870-22","technique_en":"Gravimetric method","test_object_en":"Liquid fuels: heavy heating oil, Other petroleum products: vacuum residues","parameters_zh":[{"name":"范围","range":"(0,01 – 0,50) %(m/m)"}],"search_zh":"重量法 范围 PN-ISO 10307-1:2010 | ASTM D 4870-22","technique_zh":"重量法"},{"_id":"6a836fb9af14b9c0e7b1ebcc","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna, olej napędowy, olej opałowy lekki, olej opałowy ciężki, Inne przetwory naftowe: pozostałość próżniowa (gudron), Materiały smarne: oleje bazowe smarowe","methodology":"Odczyn wyciągu wodnego","parameters":[{"name":"Zakres","range":"zasadowy – kwaśny (wartość pH 2,7 –12,4)"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Odczyn wyciągu wodnego\nZakres zasadowy – kwaśny (wartość pH 2,7 –12,4)\nMetoda elektrochemiczna","reference":"PN-C-96060:2019-03 Procedura A","norm_bases":["PN-C-96060:2019-03 Procedura A"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna, olej napędowy, olej opałowy lekki, olej opałowy ciężki, Inne przetwory naftowe: pozostałość próżniowa (gudron), Materiały smarne: oleje bazowe smarowe Odczyn wyciągu wodnego\nZakres zasadowy – kwaśny (wartość pH 2,7 –12,4)\nMetoda elektrochemiczna PN-C-96060:2019-03 Procedura A Paliwa ciekle: benzyna, olej napedowy, olej opalowy lekki, olej opalowy ciezki, Inne przetwory naftowe: pozostalosc prozniowa (gudron), Materialy smarne: oleje bazowe smarowe Odczyn wyciagu wodnego\nZakres zasadowy – kwasny (wartosc pH 2,7 –12,4)\nMetoda elektrochemiczna PN-C-96060:2019-03 Procedura A","categories":["petro","materials"],"row_index":181,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH of the water extract","parameters_en":[{"name":"Range","range":"zasadowy – kwaśny (wartość pH 2,7 –12,4)"}],"search_en":"Liquid fuels: petrol, diesel fuel, light heating oil, heavy heating oil, Other petroleum products: vacuum residue (tar), Lubricants: lubricating base oils pH of the water extract Electrochemical method Range PN-C-96060:2019-03 Procedura A","technique_en":"Electrochemical method","test_object_en":"Liquid fuels: petrol, diesel fuel, light heating oil, heavy heating oil, Other petroleum products: vacuum residue (tar), Lubricants: lubricating base oils","parameters_zh":[{"name":"范围","range":"zasadowy – kwaśny (wartość pH 2,7 –12,4)"}],"search_zh":"电化学法 范围 PN-C-96060:2019-03 Procedura A","technique_zh":"电化学法"},{"_id":"6a836fb9af14b9c0e7b1ebcd","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiały smarne: oleje bazowe, oleje silnikowe, przemysłowe oleje smarowe","methodology":"Wskaźnik lepkości na podstawie lepkości kinematycznej w 40 °C i w 100 °C","parameters":[{"name":"Zakres","range":"(85 – 100) dla olejów smarowych"},{"name":"bazowych (60 – 150) dla olejów smarowych uszlachetnionych (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik lepkości na podstawie lepkości kinematycznej w 40 °C i w 100 °C\nZakres:\nZakres (85 – 100) dla olejów smarowych\nbazowych (60 – 150) dla olejów smarowych uszlachetnionych (z obliczeń)","reference":"PN-ISO 2909:2009+Ap1:2010","norm_bases":["PN-ISO 2909:2009+Ap1:2010"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały smarne: oleje bazowe, oleje silnikowe, przemysłowe oleje smarowe Wskaźnik lepkości na podstawie lepkości kinematycznej w 40 °C i w 100 °C\nZakres:\nZakres (85 – 100) dla olejów smarowych\nbazowych (60 – 150) dla olejów smarowych uszlachetnionych (z obliczeń) PN-ISO 2909:2009+Ap1:2010 Materialy smarne: oleje bazowe, oleje silnikowe, przemyslowe oleje smarowe Wskaznik lepkosci na podstawie lepkosci kinematycznej w 40 °C i w 100 °C\nZakres:\nZakres (85 – 100) dla olejow smarowych\nbazowych (60 – 150) dla olejow smarowych uszlachetnionych (z obliczen) PN-ISO 2909:2009+Ap1:2010","categories":["materials","petro"],"row_index":182,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Viscosity index based on kinematic viscosity at 40 °C and at 100 °C","parameters_en":[{"name":"Range","range":"(85 – 100) dla olejów smarowych"},{"name":"base (60 – 150) for additive-treated lubricating oils (calculated)"}],"search_en":"Lubricants: base oils, engine oils, industrial lubricating oils Viscosity index based on kinematic viscosity at 40 °C and at 100 °C Range base (60 – 150) for additive-treated lubricating oils (calculated) PN-ISO 2909:2009+Ap1:2010","test_object_en":"Lubricants: base oils, engine oils, industrial lubricating oils","parameters_zh":[{"name":"范围","range":"(85 – 100) dla olejów smarowych"},{"name":"bazowych (60 – 150) dla olejów smarowych uszlachetnionych (z obliczeń)"}],"search_zh":"润滑材料：基础油、发动机油、工业润滑油 范围 PN-ISO 2909:2009+Ap1:2010","test_object_zh":"润滑材料：基础油、发动机油、工业润滑油"},{"_id":"6a836fb9af14b9c0e7b1ebce","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiały smarne: oleje bazowe, oleje silnikowe, przemysłowe oleje smarowe","methodology":"Barwa","parameters":[{"name":"Zakres","range":"0,5 – 8,0"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Barwa\nZakres 0,5 – 8,0\nMetoda wizualna","reference":"ASTM D 1500-24","norm_bases":["ASTM D 1500-24"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały smarne: oleje bazowe, oleje silnikowe, przemysłowe oleje smarowe Barwa\nZakres 0,5 – 8,0\nMetoda wizualna ASTM D 1500-24 Materialy smarne: oleje bazowe, oleje silnikowe, przemyslowe oleje smarowe Barwa\nZakres 0,5 – 8,0\nMetoda wizualna ASTM D 1500-24","categories":["materials","petro"],"row_index":183,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"0,5 – 8,0"}],"search_en":"Lubricants: base oils, engine oils, industrial lubricating oils Colour Visual method Range ASTM D 1500-24","technique_en":"Visual method","test_object_en":"Lubricants: base oils, engine oils, industrial lubricating oils","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"0,5 – 8,0"}],"search_zh":"润滑材料：基础油、发动机油、工业润滑油 色度 目视法 范围 ASTM D 1500-24","technique_zh":"目视法","test_object_zh":"润滑材料：基础油、发动机油、工业润滑油"},{"_id":"6a836fb9af14b9c0e7b1ebcf","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiały smarne: oleje bazowe, oleje silnikowe, przemysłowe oleje smarowe","methodology":"Temperatura zapłonu","parameters":[{"name":"Zakres","range":"(110 – 280) °C"}],"technique":"Metoda otwartego tygla Cleveland’a","techniques":["Metoda otwartego tygla Cleveland’a"],"computed":[],"activity":"Temperatura zapłonu\nZakres (110 – 280) °C\nMetoda otwartego tygla Cleveland’a","reference":"PN-EN ISO 2592:2017-10","norm_bases":["PN-EN ISO 2592:2017-10"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały smarne: oleje bazowe, oleje silnikowe, przemysłowe oleje smarowe Temperatura zapłonu\nZakres (110 – 280) °C\nMetoda otwartego tygla Cleveland’a PN-EN ISO 2592:2017-10 Materialy smarne: oleje bazowe, oleje silnikowe, przemyslowe oleje smarowe Temperatura zaplonu\nZakres (110 – 280) °C\nMetoda otwartego tygla Cleveland’a PN-EN ISO 2592:2017-10","categories":["materials","petro"],"row_index":184,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Flash point","parameters_en":[{"name":"Range","range":"(110 – 280) °C"}],"search_en":"Lubricants: base oils, engine oils, industrial lubricating oils Flash point Cleveland open cup method Range PN-EN ISO 2592:2017-10","technique_en":"Cleveland open cup method","test_object_en":"Lubricants: base oils, engine oils, industrial lubricating oils","parameters_zh":[{"name":"范围","range":"(110 – 280) °C"}],"search_zh":"润滑材料：基础油、发动机油、工业润滑油 闪点 范围 PN-EN ISO 2592:2017-10","methodology_zh":"闪点","test_object_zh":"润滑材料：基础油、发动机油、工业润滑油"},{"_id":"6a836fb9af14b9c0e7b1ebd0","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiały smarne: oleje bazowe, oleje silnikowe, przemysłowe oleje smarowe","methodology":"Lepkość kinematyczna w 40°C i 100°C","parameters":[{"name":"Zakres","range":"(2,600 – 200,0) mm2/s"}],"technique":"Metoda kapilarna","techniques":["Metoda kapilarna"],"computed":[],"activity":"Lepkość kinematyczna w 40°C i 100°C\nZakres (2,600 – 200,0) mm2/s\nMetoda kapilarna","reference":"PN-EN ISO 3104:2024-01","norm_bases":["PN-EN ISO 3104:2024-01"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały smarne: oleje bazowe, oleje silnikowe, przemysłowe oleje smarowe Lepkość kinematyczna w 40°C i 100°C\nZakres (2,600 – 200,0) mm2/s\nMetoda kapilarna PN-EN ISO 3104:2024-01 Materialy smarne: oleje bazowe, oleje silnikowe, przemyslowe oleje smarowe Lepkosc kinematyczna w 40°C i 100°C\nZakres (2,600 – 200,0) mm2/s\nMetoda kapilarna PN-EN ISO 3104:2024-01","categories":["materials","petro"],"row_index":185,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kinematic viscosity at 40°C and 100°C","parameters_en":[{"name":"Range","range":"(2,600 – 200,0) mm2/s"}],"search_en":"Lubricants: base oils, engine oils, industrial lubricating oils Kinematic viscosity at 40°C and 100°C Capillary method Range PN-EN ISO 3104:2024-01","technique_en":"Capillary method","test_object_en":"Lubricants: base oils, engine oils, industrial lubricating oils","parameters_zh":[{"name":"范围","range":"(2,600 – 200,0) mm2/s"}],"search_zh":"润滑材料：基础油、发动机油、工业润滑油 毛细管法 范围 PN-EN ISO 3104:2024-01","technique_zh":"毛细管法","test_object_zh":"润滑材料：基础油、发动机油、工业润滑油"},{"_id":"6a836fb9af14b9c0e7b1ebd1","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiały smarne: oleje bazowe, oleje silnikowe, przemysłowe oleje smarowe","methodology":"Temperatura płynięcia","parameters":[{"name":"[(+6)","range":"(-30)] °C"}],"technique":"Metoda optyczna i wizualna","techniques":["Metoda optyczna i wizualna"],"computed":[],"activity":"Temperatura płynięcia\n[(+6) (-30)] °C\nMetoda optyczna i wizualna","reference":"PN-EN ISO 3016:2019-06","norm_bases":["PN-EN ISO 3016:2019-06"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały smarne: oleje bazowe, oleje silnikowe, przemysłowe oleje smarowe Temperatura płynięcia\n[(+6) (-30)] °C\nMetoda optyczna i wizualna PN-EN ISO 3016:2019-06 Materialy smarne: oleje bazowe, oleje silnikowe, przemyslowe oleje smarowe Temperatura plyniecia\n[(+6) (-30)] °C\nMetoda optyczna i wizualna PN-EN ISO 3016:2019-06","categories":["materials","petro"],"row_index":186,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Pour point","parameters_en":[{"name":"[(+6)","range":"(-30)] °C"}],"search_en":"Lubricants: base oils, engine oils, industrial lubricating oils Pour point Optical and visual method [(+6) PN-EN ISO 3016:2019-06","technique_en":"Optical and visual method","test_object_en":"Lubricants: base oils, engine oils, industrial lubricating oils","methodology_zh":"倾点","search_zh":"润滑材料：基础油、发动机油、工业润滑油 倾点 PN-EN ISO 3016:2019-06","test_object_zh":"润滑材料：基础油、发动机油、工业润滑油"},{"_id":"6a836fb9af14b9c0e7b1ebd2","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiały smarne: oleje bazowe, oleje silnikowe, przemysłowe oleje smarowe","methodology":"Liczba kwasowa","parameters":[{"name":"Zakres","range":"(0,1 – 5,0) mg KOH/g"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Liczba kwasowa\nZakres (0,1 – 5,0) mg KOH/g\nMetoda miareczkowa","reference":"PN-ISO 6618:2011","norm_bases":["PN-ISO 6618:2011"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały smarne: oleje bazowe, oleje silnikowe, przemysłowe oleje smarowe Liczba kwasowa\nZakres (0,1 – 5,0) mg KOH/g\nMetoda miareczkowa PN-ISO 6618:2011 Materialy smarne: oleje bazowe, oleje silnikowe, przemyslowe oleje smarowe Liczba kwasowa\nZakres (0,1 – 5,0) mg KOH/g\nMetoda miareczkowa PN-ISO 6618:2011","categories":["materials","petro"],"row_index":187,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Acid value","parameters_en":[{"name":"Range","range":"(0,1 – 5,0) mg KOH/g"}],"search_en":"Lubricants: base oils, engine oils, industrial lubricating oils Acid value Titrimetric method Range PN-ISO 6618:2011","technique_en":"Titrimetric method","test_object_en":"Lubricants: base oils, engine oils, industrial lubricating oils","parameters_zh":[{"name":"范围","range":"(0,1 – 5,0) mg KOH/g"}],"search_zh":"润滑材料：基础油、发动机油、工业润滑油 酸值 滴定法 范围 PN-ISO 6618:2011","technique_zh":"滴定法","methodology_zh":"酸值","test_object_zh":"润滑材料：基础油、发动机油、工业润滑油"},{"_id":"6a836fb9af14b9c0e7b1ebd3","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiały smarne: oleje bazowe, oleje silnikowe, przemysłowe oleje smarowe","methodology":"Pozostałość po spopieleniu","parameters":[{"name":"Zakres","range":"(0,001 – 0,005) %(m/m)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Pozostałość po spopieleniu\nZakres (0,001 – 0,005) %(m/m)\nMetoda wagowa","reference":"PN-EN ISO 6245:2008","norm_bases":["PN-EN ISO 6245:2008"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały smarne: oleje bazowe, oleje silnikowe, przemysłowe oleje smarowe Pozostałość po spopieleniu\nZakres (0,001 – 0,005) %(m/m)\nMetoda wagowa PN-EN ISO 6245:2008 Materialy smarne: oleje bazowe, oleje silnikowe, przemyslowe oleje smarowe Pozostalosc po spopieleniu\nZakres (0,001 – 0,005) %(m/m)\nMetoda wagowa PN-EN ISO 6245:2008","categories":["materials","petro"],"row_index":188,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Residue after incineration","parameters_en":[{"name":"Range","range":"(0,001 – 0,005) %(m/m)"}],"search_en":"Lubricants: base oils, engine oils, industrial lubricating oils Residue after incineration Gravimetric method Range PN-EN ISO 6245:2008","technique_en":"Gravimetric method","test_object_en":"Lubricants: base oils, engine oils, industrial lubricating oils","parameters_zh":[{"name":"范围","range":"(0,001 – 0,005) %(m/m)"}],"search_zh":"润滑材料：基础油、发动机油、工业润滑油 灰化残渣 重量法 范围 PN-EN ISO 6245:2008","technique_zh":"重量法","test_object_zh":"润滑材料：基础油、发动机油、工业润滑油","methodology_zh":"灰化残渣"},{"_id":"6a836fb9af14b9c0e7b1ebd4","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiały smarne: przemysłowe oleje smarowe, Paliwa ciekłe: olej opałowy ciężki","methodology":"Zawartość wody","parameters":[{"name":"Zakres","range":"(0,05 – 5,00) %(v/m)"}],"technique":"Metoda destylacyjna","techniques":["Metoda destylacyjna"],"computed":[],"activity":"Zawartość wody\nZakres (0,05 – 5,00) %(v/m)\nMetoda destylacyjna","reference":"ASTM D 95-23ɛ1","norm_bases":["ASTM D 95-23ɛ1"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały smarne: przemysłowe oleje smarowe, Paliwa ciekłe: olej opałowy ciężki Zawartość wody\nZakres (0,05 – 5,00) %(v/m)\nMetoda destylacyjna ASTM D 95-23ɛ1 Materialy smarne: przemyslowe oleje smarowe, Paliwa ciekle: olej opalowy ciezki Zawartosc wody\nZakres (0,05 – 5,00) %(v/m)\nMetoda destylacyjna ASTM D 95-23ɛ1","categories":["petro","materials","water"],"row_index":189,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water content","parameters_en":[{"name":"Range","range":"(0,05 – 5,00) %(v/m)"}],"search_en":"Lubricating materials: industrial lubricating oils, Liquid fuels: heavy fuel oil Water content Distillation method Range ASTM D 95-23ɛ1","technique_en":"Distillation method","test_object_en":"Lubricating materials: industrial lubricating oils, Liquid fuels: heavy fuel oil","methodology_zh":"水分含量","parameters_zh":[{"name":"范围","range":"(0,05 – 5,00) %(v/m)"}],"search_zh":"水分含量 蒸馏法 范围 ASTM D 95-23ɛ1","technique_zh":"蒸馏法"},{"_id":"6a836fb9af14b9c0e7b1ebd5","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Inne przetwory naftowe: gacz parafinowy","methodology":"Zawartość oleju","parameters":[{"name":"Zakres","range":"(0,20 – 15,00) %(m/m)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość oleju\nZakres (0,20 – 15,00) %(m/m)\nMetoda wagowa","reference":"ASTM D 721-25","norm_bases":["ASTM D 721-25"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Inne przetwory naftowe: gacz parafinowy Zawartość oleju\nZakres (0,20 – 15,00) %(m/m)\nMetoda wagowa ASTM D 721-25 Inne przetwory naftowe: gacz parafinowy Zawartosc oleju\nZakres (0,20 – 15,00) %(m/m)\nMetoda wagowa ASTM D 721-25","categories":["petro"],"row_index":190,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Oil content","parameters_en":[{"name":"Range","range":"(0,20 – 15,00) %(m/m)"}],"search_en":"Other petroleum products: slack wax Oil content Gravimetric method Range ASTM D 721-25","technique_en":"Gravimetric method","test_object_en":"Other petroleum products: slack wax","parameters_zh":[{"name":"范围","range":"(0,20 – 15,00) %(m/m)"}],"search_zh":"含油量 重量法 范围 ASTM D 721-25","technique_zh":"重量法","methodology_zh":"含油量"},{"_id":"6a836fb9af14b9c0e7b1ebd6","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Inne przetwory naftowe: gacz parafinowy","methodology":"Temperatura krzepnięcia","parameters":[{"name":"Zakres","range":"(45 – 65) °C"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Temperatura krzepnięcia\nZakres (45 – 65) °C\nMetoda wizualna","reference":"PN-ISO 2207:2011","norm_bases":["PN-ISO 2207:2011"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Inne przetwory naftowe: gacz parafinowy Temperatura krzepnięcia\nZakres (45 – 65) °C\nMetoda wizualna PN-ISO 2207:2011 Inne przetwory naftowe: gacz parafinowy Temperatura krzepniecia\nZakres (45 – 65) °C\nMetoda wizualna PN-ISO 2207:2011","categories":["other"],"row_index":191,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Freezing point","parameters_en":[{"name":"Range","range":"(45 – 65) °C"}],"search_en":"Other petroleum products: slack wax Freezing point Visual method Range PN-ISO 2207:2011","technique_en":"Visual method","test_object_en":"Other petroleum products: slack wax","methodology_zh":"凝固点","parameters_zh":[{"name":"范围","range":"(45 – 65) °C"}],"search_zh":"凝固点 目视法 范围 PN-ISO 2207:2011","technique_zh":"目视法"},{"_id":"6a836fb9af14b9c0e7b1ebd7","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie metali","parameters":[{"name":"Cr, Cd, Pb, Cu, Ni, Zn, Fe, V"},{"name":"Zakres","range":"(0,010 – 100) mg/l"},{"name":"Co, Ag, Ba, B, Al","range":"(0,010 – 50,0) mg/l"},{"name":"Na, K, Ca, Mg","range":"(1,00 – 1000) mg/l"},{"name":"Stężenie metali As, Sb","range":"(0,010 – 20,0) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES); Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES)"],"computed":[],"activity":"Stężenie metali\nZakres:\nCr, Cd, Pb, Cu, Ni, Zn, Fe, V\nZakres (0,010 – 100) mg/l\nCo, Ag, Ba, B, Al (0,010 – 50,0) mg/l\nNa, K, Ca, Mg (1,00 – 1000) mg/l\nStężenie metali As, Sb (0,010 – 20,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES); Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie metali\nZakres:\nCr, Cd, Pb, Cu, Ni, Zn, Fe, V\nZakres (0,010 – 100) mg/l\nCo, Ag, Ba, B, Al (0,010 – 50,0) mg/l\nNa, K, Ca, Mg (1,00 – 1000) mg/l\nStężenie metali As, Sb (0,010 – 20,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES); Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES) PN-EN ISO 11885:2009 Scieki Stezenie metali\nZakres:\nCr, Cd, Pb, Cu, Ni, Zn, Fe, V\nZakres (0,010 – 100) mg/l\nCo, Ag, Ba, B, Al (0,010 – 50,0) mg/l\nNa, K, Ca, Mg (1,00 – 1000) mg/l\nStezenie metali As, Sb (0,010 – 20,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES); Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej z generowaniem wodorkow (HG-ICP-OES) PN-EN ISO 11885:2009","categories":["materials","water"],"row_index":192,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Metal concentrations","parameters_en":[{"name":"Cr, Cd, Pb, Cu, Ni, Zn, Fe, V"},{"name":"Range","range":"(0,010 – 100) mg/l"},{"name":"Co, Ag, Ba, B, Al","range":"(0,010 – 50,0) mg/l"},{"name":"Na, K, Ca, Mg","range":"(1,00 – 1000) mg/l"},{"name":"Metal concentration As, Sb","range":"(0,010 – 20,0) mg/l"}],"search_en":"Wastewater Metal concentrations Inductively coupled plasma atomic emission spectrometry (ICP-OES); Inductively coupled plasma atomic emission spectrometry with hydride generation (HG-ICP-OES) Cr, Cd, Pb, Cu, Ni, Zn, Fe, V Range Co, Ag, Ba, B, Al Na, K, Ca, Mg Metal concentration As, Sb PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma atomic emission spectrometry (ICP-OES); Inductively coupled plasma atomic emission spectrometry with hydride generation (HG-ICP-OES)","test_object_en":"Wastewater","methodology_zh":"金属浓度","parameters_zh":[{"name":"Cr, Cd, Pb, Cu, Ni, Zn, Fe, V"},{"name":"范围","range":"(0,010 – 100) mg/l"},{"name":"Co, Ag, Ba, B, Al","range":"(0,010 – 50,0) mg/l"},{"name":"Na, K, Ca, Mg","range":"(1,00 – 1000) mg/l"},{"name":"Stężenie metali As, Sb","range":"(0,010 – 20,0) mg/l"}],"search_zh":"污水 金属浓度 范围 PN-EN ISO 11885:2009","test_object_zh":"污水"},{"_id":"6a836fb9af14b9c0e7b1ebd8","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki oczyszczone","methodology":"Stężenie metali","parameters":[{"name":"Cr, Cd, Cu, Ni, Mn, V","range":"(0,010 – 2,00) mg/l"},{"name":"Mg, K, Na, Ca","range":"(1,00 – 1000) mg/l"},{"name":"Zn, Pb, Fe","range":"(0,010 – 100) mg/l"},{"name":"Ba, Al., Ag","range":"(0,010 – 50,0) mg/l"},{"name":"Stężenie metali As","range":"(0,010 – 2,00) mg/l"},{"name":"Se, Sb","range":"(0.010 – 20,0) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES); Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnej sprzężonej z generowaniem wodorków (HG-ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnej sprzężonej z generowaniem wodorków (HG-ICP-OES)"],"computed":[],"activity":"Stężenie metali\nZakres:\nCr, Cd, Cu, Ni, Mn, V (0,010 – 2,00) mg/l\nMg, K, Na, Ca (1,00 – 1000) mg/l\nZn, Pb, Fe (0,010 – 100) mg/l\nBa, Al., Ag (0,010 – 50,0) mg/l\nStężenie metali As (0,010 – 2,00) mg/l\nSe, Sb (0.010 – 20,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES); Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnej sprzężonej z generowaniem wodorków (HG-ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki oczyszczone Stężenie metali\nZakres:\nCr, Cd, Cu, Ni, Mn, V (0,010 – 2,00) mg/l\nMg, K, Na, Ca (1,00 – 1000) mg/l\nZn, Pb, Fe (0,010 – 100) mg/l\nBa, Al., Ag (0,010 – 50,0) mg/l\nStężenie metali As (0,010 – 2,00) mg/l\nSe, Sb (0.010 – 20,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES); Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnej sprzężonej z generowaniem wodorków (HG-ICP-OES) PN-EN ISO 11885:2009 Woda, scieki oczyszczone Stezenie metali\nZakres:\nCr, Cd, Cu, Ni, Mn, V (0,010 – 2,00) mg/l\nMg, K, Na, Ca (1,00 – 1000) mg/l\nZn, Pb, Fe (0,010 – 100) mg/l\nBa, Al., Ag (0,010 – 50,0) mg/l\nStezenie metali As (0,010 – 2,00) mg/l\nSe, Sb (0.010 – 20,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES); Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnej sprzezonej z generowaniem wodorkow (HG-ICP-OES) PN-EN ISO 11885:2009","categories":["water","materials"],"row_index":193,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Metal concentrations","parameters_en":[{"name":"Cr, Cd, Cu, Ni, Mn, V","range":"(0,010 – 2,00) mg/l"},{"name":"Mg, K, Na, Ca","range":"(1,00 – 1000) mg/l"},{"name":"Zn, Pb, Fe","range":"(0,010 – 100) mg/l"},{"name":"Ba, Al., Ag","range":"(0,010 – 50,0) mg/l"},{"name":"Metal concentration As","range":"(0,010 – 2,00) mg/l"},{"name":"Se, Sb","range":"(0.010 – 20,0) mg/l"}],"search_en":"Water, treated wastewater Metal concentrations Inductively coupled plasma atomic emission spectrometry (ICP-OES); Inductively coupled plasma atomic emission spectrometry with hydride generation (HG-ICP-OES) Cr, Cd, Cu, Ni, Mn, V Mg, K, Na, Ca Zn, Pb, Fe Ba, Al., Ag Metal concentration As Se, Sb PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma atomic emission spectrometry (ICP-OES); Inductively coupled plasma atomic emission spectrometry with hydride generation (HG-ICP-OES)","test_object_en":"Water, treated wastewater","methodology_zh":"金属浓度","search_zh":"水、处理后废水 金属浓度 PN-EN ISO 11885:2009","test_object_zh":"水、处理后废水"},{"_id":"6a836fb9af14b9c0e7b1ebd9","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie pierwiastków As, Cr, Cd, Pb","parameters":[{"name":"Zakres","range":"(0,00010 – 0,050) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej z detekcją spektrometrią mas (ICP-MS)","techniques":["Metoda emisyjnej spektrometrii atomowej z detekcją spektrometrią mas (ICP-MS)"],"computed":[],"activity":"Stężenie pierwiastków As, Cr, Cd, Pb\nZakres (0,00010 – 0,050) mg/l\nMetoda emisyjnej spektrometrii atomowej z detekcją spektrometrią mas (ICP-MS)","reference":"PN-EN ISO 17294-2:2024-04","norm_bases":["PN-EN ISO 17294-2:2024-04"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie pierwiastków As, Cr, Cd, Pb\nZakres (0,00010 – 0,050) mg/l\nMetoda emisyjnej spektrometrii atomowej z detekcją spektrometrią mas (ICP-MS) PN-EN ISO 17294-2:2024-04 Woda, scieki Stezenie pierwiastkow As, Cr, Cd, Pb\nZakres (0,00010 – 0,050) mg/l\nMetoda emisyjnej spektrometrii atomowej z detekcja spektrometria mas (ICP-MS) PN-EN ISO 17294-2:2024-04","categories":["water"],"row_index":194,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element concentrations As, Cr, Cd, Pb","parameters_en":[{"name":"Range","range":"(0,00010 – 0,050) mg/l"}],"search_en":"Water, wastewater Element concentrations As, Cr, Cd, Pb Atomic emission spectrometry with mass spectrometry detection (ICP-MS) Range PN-EN ISO 17294-2:2024-04","technique_en":"Atomic emission spectrometry with mass spectrometry detection (ICP-MS)","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,00010 – 0,050) mg/l"}],"search_zh":"水、废水 范围 PN-EN ISO 17294-2:2024-04","test_object_zh":"水、废水"},{"_id":"6a836fb9af14b9c0e7b1ebda","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiały budowlane: gips","methodology":"Zawartość Na2O, K2O","parameters":[{"name":"Na2O","range":"(0,010 – 0,500) %(m/m)"},{"name":"K2O","range":"(0,010 – 0,500) %(m/m)"},{"name":"Zawartość rozpuszczonego MgO MgO","range":"(0,001 – 0,100) %(m/m)"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość Na2O, K2O\nZakres:\nNa2O (0,010 – 0,500) %(m/m)\nK2O (0,010 – 0,500) %(m/m)\nZawartość rozpuszczonego MgO MgO (0,001 – 0,100) %(m/m)\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"VGB-M 701-e/2008 p. 8.7","norm_bases":["VGB-M 701-e/2008 p. 8.7"],"lab_section":"Pracownia Przerobu Ropy PP2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały budowlane: gips Zawartość Na2O, K2O\nZakres:\nNa2O (0,010 – 0,500) %(m/m)\nK2O (0,010 – 0,500) %(m/m)\nZawartość rozpuszczonego MgO MgO (0,001 – 0,100) %(m/m)\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) VGB-M 701-e/2008 p. 8.7 Materialy budowlane: gips Zawartosc Na2O, K2O\nZakres:\nNa2O (0,010 – 0,500) %(m/m)\nK2O (0,010 – 0,500) %(m/m)\nZawartosc rozpuszczonego MgO MgO (0,001 – 0,100) %(m/m)\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) VGB-M 701-e/2008 p. 8.7","categories":["materials","construction"],"row_index":195,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Na2O, K2O content","parameters_en":[{"name":"Na2O","range":"(0,010 – 0,500) %(m/m)"},{"name":"K2O","range":"(0,010 – 0,500) %(m/m)"},{"name":"Content of dissolved MgO MgO","range":"(0,001 – 0,100) %(m/m)"}],"search_en":"Building materials: gypsum Na2O, K2O content Inductively coupled plasma optical emission spectrometry (ICP-OES) Na2O K2O Content of dissolved MgO MgO VGB-M 701-e/2008 p. 8.7","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Building materials: gypsum","search_zh":"电感耦合等离子体原子发射光谱法（ICP-OES） Na2O K2O VGB-M 701-e/2008 p. 8.7","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","parameters_zh":[{"name":"Na2O","range":"(0,010 – 0,500) %(m/m)"},{"name":"K2O","range":"(0,010 – 0,500) %(m/m)"},{"name":"Zawartość rozpuszczonego MgO MgO","range":"(0,001 – 0,100) %(m/m)"}]},{"_id":"6a836fb9af14b9c0e7b1ebdb","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Pobieranie próbek do oceny narażenia zawodowego na:","parameters":[{"name":"czynniki pyłowe"},{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna"},{"name":"metale i ich związki, w tym"},{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna"},{"name":"substancje organiczne, w tym"},{"name":"frakcja wdychalna"},{"name":"substancje nieorganiczne, w tym"},{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna"},{"name":"frakcja torakalna"}],"technique":"Metoda dozymetrii indywidualnej","techniques":["Metoda dozymetrii indywidualnej"],"computed":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe\nfrakcja wdychalna\nfrakcja respirabilna\nmetale i ich związki, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nsubstancje organiczne, w tym\nfrakcja wdychalna\nsubstancje nieorganiczne, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nfrakcja torakalna\nMetoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002+Az1:2004"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe\nfrakcja wdychalna\nfrakcja respirabilna\nmetale i ich związki, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nsubstancje organiczne, w tym\nfrakcja wdychalna\nsubstancje nieorganiczne, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nfrakcja torakalna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy − powietrze Pobieranie probek do oceny narazenia zawodowego na:\nZakres:\nczynniki pylowe\nfrakcja wdychalna\nfrakcja respirabilna\nmetale i ich zwiazki, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nsubstancje organiczne, w tym\nfrakcja wdychalna\nsubstancje nieorganiczne, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nfrakcja torakalna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002+Az1:2004","categories":["materials","environment"],"row_index":196,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for the assessment of occupational exposure to:","parameters_en":[{"name":"dust agents"},{"name":"inhalable fraction"},{"name":"respirable fraction"},{"name":"metals and their compounds, including"},{"name":"inhalable fraction"},{"name":"respirable fraction"},{"name":"organic substances, including"},{"name":"inhalable fraction"},{"name":"inorganic substances, including"},{"name":"inhalable fraction"},{"name":"respirable fraction"},{"name":"thoracic fraction"}],"search_en":"Workplace environment − air Sampling for the assessment of occupational exposure to: Personal dosimetry method dust agents inhalable fraction respirable fraction metals and their compounds, including inhalable fraction respirable fraction organic substances, including inhalable fraction inorganic substances, including inhalable fraction respirable fraction thoracic fraction PN-Z-04008-7:2002+Az1:2004","technique_en":"Personal dosimetry method","test_object_en":"Workplace environment − air","methodology_zh":"职业接触评估采样，针对：","parameters_zh":[{"name":"粉尘因素"},{"name":"可吸入组分"},{"name":"呼吸性组分"},{"name":"金属及其化合物，包括"},{"name":"可吸入组分"},{"name":"呼吸性组分"},{"name":"有机物质，包括"},{"name":"可吸入组分"},{"name":"无机物质，包括"},{"name":"可吸入组分"},{"name":"呼吸性组分"},{"name":"胸腔组分"}],"search_zh":"工作环境 − 空气 职业接触评估采样，针对： 个体剂量测定法 粉尘因素 可吸入组分 呼吸性组分 金属及其化合物，包括 可吸入组分 呼吸性组分 有机物质，包括 可吸入组分 无机物质，包括 可吸入组分 呼吸性组分 胸腔组分 PN-Z-04008-7:2002+Az1:2004","technique_zh":"个体剂量测定法","test_object_zh":"工作环境 − 空气"},{"_id":"6a836fb9af14b9c0e7b1ebdc","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Pobieranie próbek do oceny narażenia zawodowego na:","parameters":[{"name":"substancje organiczne,"},{"name":"substancje nieorganiczne, w tym"},{"name":"frakcja wdychalna"}],"technique":"Metoda stacjonarna","techniques":["Metoda stacjonarna"],"computed":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nsubstancje organiczne,\nsubstancje nieorganiczne, w tym\nfrakcja wdychalna\nMetoda stacjonarna","reference":"PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002+Az1:2004"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nsubstancje organiczne,\nsubstancje nieorganiczne, w tym\nfrakcja wdychalna\nMetoda stacjonarna PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy − powietrze Pobieranie probek do oceny narazenia zawodowego na:\nZakres:\nsubstancje organiczne,\nsubstancje nieorganiczne, w tym\nfrakcja wdychalna\nMetoda stacjonarna PN-Z-04008-7:2002+Az1:2004","categories":["environment"],"row_index":197,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for the assessment of occupational exposure to:","parameters_en":[{"name":"organic substances,"},{"name":"inorganic substances, including"},{"name":"inhalable fraction"}],"search_en":"Workplace environment − air Sampling for the assessment of occupational exposure to: Stationary method organic substances, inorganic substances, including inhalable fraction PN-Z-04008-7:2002+Az1:2004","technique_en":"Stationary method","test_object_en":"Workplace environment − air","methodology_zh":"职业接触评估采样，针对：","parameters_zh":[{"name":"有机物质，"},{"name":"无机物质，包括"},{"name":"可吸入组分"}],"search_zh":"工作环境 − 空气 职业接触评估采样，针对： 定点测定法 有机物质， 无机物质，包括 可吸入组分 PN-Z-04008-7:2002+Az1:2004","test_object_zh":"工作环境 − 空气","technique_zh":"定点测定法"},{"_id":"6a836fb9af14b9c0e7b1ebdd","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Wskaźnik narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002+Az1:2004"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Wskaźnik narażenia (z obliczeń) PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy − powietrze Wskaznik narazenia (z obliczen) PN-Z-04008-7:2002+Az1:2004","categories":["environment"],"row_index":198,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Exposure index (calculated)","search_en":"Workplace environment − air Exposure index (calculated) PN-Z-04008-7:2002+Az1:2004","test_object_en":"Workplace environment − air","methodology_zh":"暴露指数（计算得出）","search_zh":"工作环境 − 空气 暴露指数（计算得出） PN-Z-04008-7:2002+Az1:2004","test_object_zh":"工作环境 − 空气"},{"_id":"6a836fb9af14b9c0e7b1ebde","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość glikolu etylenowego","parameters":[{"name":"Zakres","range":"(0,83 – 333,3)mg/m3"},{"name":"Zakres","range":"(0,025 – 1,00) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość glikolu etylenowego\nZakres:\nZakres (0,83 – 333,3)mg/m3\nZakres (0,025 – 1,00) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-88/Z-04203.02","norm_bases":["PN-88/Z-04203.02"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość glikolu etylenowego\nZakres:\nZakres (0,83 – 333,3)mg/m3\nZakres (0,025 – 1,00) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-88/Z-04203.02 Srodowisko pracy − powietrze Stezenie/zawartosc glikolu etylenowego\nZakres:\nZakres (0,83 – 333,3)mg/m3\nZakres (0,025 – 1,00) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-88/Z-04203.02","categories":["environment"],"row_index":199,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ethylene glycol concentration/content","parameters_en":[{"name":"Range","range":"(0,83 – 333,3)mg/m3"},{"name":"Range","range":"(0,025 – 1,00) mg w próbce"}],"search_en":"Workplace environment − air Ethylene glycol concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-88/Z-04203.02","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"范围","range":"(0,83 – 333,3)mg/m3"},{"name":"范围","range":"(0,025 – 1,00) mg w próbce"}],"search_zh":"工作环境 − 空气 乙二醇的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-88/Z-04203.02","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作环境 − 空气","methodology_zh":"乙二醇的浓度/含量"},{"_id":"6a836fb9af14b9c0e7b1ebdf","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość buta-1,3-dienu","parameters":[{"name":"Zakres","range":"(0,13 – 6,67) mg/m3"},{"name":"Zakres","range":"(0,004 – 0,150) mg w próbce"},{"name":"Zakres","range":"(0,06 – 2,97) ppm"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość buta-1,3-dienu\nZakres:\nZakres (0,13 – 6,67) mg/m3\nZakres (0,004 – 0,150) mg w próbce\nZakres (0,06 – 2,97) ppm\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-84/Z-04014.02","norm_bases":["PN-84/Z-04014.02"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość buta-1,3-dienu\nZakres:\nZakres (0,13 – 6,67) mg/m3\nZakres (0,004 – 0,150) mg w próbce\nZakres (0,06 – 2,97) ppm\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-84/Z-04014.02 Srodowisko pracy − powietrze Stezenie/zawartosc buta-1,3-dienu\nZakres:\nZakres (0,13 – 6,67) mg/m3\nZakres (0,004 – 0,150) mg w probce\nZakres (0,06 – 2,97) ppm\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-84/Z-04014.02","categories":["environment"],"row_index":200,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of buta-1,3-diene","parameters_en":[{"name":"Range","range":"(0,13 – 6,67) mg/m3"},{"name":"Range","range":"(0,004 – 0,150) mg w próbce"},{"name":"Range","range":"(0,06 – 2,97) ppm"}],"search_en":"Workplace environment − air Concentration/content of buta-1,3-diene Gas chromatography with flame ionization detection (GC-FID) Range Range Range PN-84/Z-04014.02","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"范围","range":"(0,13 – 6,67) mg/m3"},{"name":"范围","range":"(0,004 – 0,150) mg w próbce"},{"name":"范围","range":"(0,06 – 2,97) ppm"}],"search_zh":"工作环境 − 空气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 范围 PN-84/Z-04014.02","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作环境 − 空气"},{"_id":"6a836fb9af14b9c0e7b1ebe0","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość buta-1,3-dienu","parameters":[{"name":"Zakres","range":"(0,22 – 4,44) mg/m3"},{"name":"Zakres","range":"(0,00098 – 0,02) mg w próbce"},{"name":"Zakres","range":"(0,10 – 1,98) ppm"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość buta-1,3-dienu\nZakres:\nZakres (0,22 – 4,44) mg/m3\nZakres (0,00098 – 0,02) mg w próbce\nZakres (0,10 – 1,98) ppm\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04438:2021-07","norm_bases":["PN-Z-04438:2021-07"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość buta-1,3-dienu\nZakres:\nZakres (0,22 – 4,44) mg/m3\nZakres (0,00098 – 0,02) mg w próbce\nZakres (0,10 – 1,98) ppm\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04438:2021-07 Srodowisko pracy − powietrze Stezenie/zawartosc buta-1,3-dienu\nZakres:\nZakres (0,22 – 4,44) mg/m3\nZakres (0,00098 – 0,02) mg w probce\nZakres (0,10 – 1,98) ppm\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04438:2021-07","categories":["environment"],"row_index":201,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of buta-1,3-diene","parameters_en":[{"name":"Range","range":"(0,22 – 4,44) mg/m3"},{"name":"Range","range":"(0,00098 – 0,02) mg w próbce"},{"name":"Range","range":"(0,10 – 1,98) ppm"}],"search_en":"Workplace environment − air Concentration/content of buta-1,3-diene Gas chromatography with flame ionization detection (GC-FID) Range Range Range PN-Z-04438:2021-07","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"范围","range":"(0,22 – 4,44) mg/m3"},{"name":"范围","range":"(0,00098 – 0,02) mg w próbce"},{"name":"范围","range":"(0,10 – 1,98) ppm"}],"search_zh":"工作环境 − 空气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 范围 PN-Z-04438:2021-07","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作环境 − 空气"},{"_id":"6a836fb9af14b9c0e7b1ebe1","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość NN-dimetyloformamidu","parameters":[{"name":"Zakres","range":"(1,00 – 333,3) mg/m3"},{"name":"Zakres","range":"(0,03 – 1,00) mg w próbce"},{"name":"Zakres","range":"(0,33 – 109,9) ppm"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość NN-dimetyloformamidu\nZakres:\nZakres (1,00 – 333,3) mg/m3\nZakres (0,03 – 1,00) mg w próbce\nZakres (0,33 – 109,9) ppm\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-89/Z-04209.02","norm_bases":["PN-89/Z-04209.02"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość NN-dimetyloformamidu\nZakres:\nZakres (1,00 – 333,3) mg/m3\nZakres (0,03 – 1,00) mg w próbce\nZakres (0,33 – 109,9) ppm\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-89/Z-04209.02 Srodowisko pracy − powietrze Stezenie/zawartosc NN-dimetyloformamidu\nZakres:\nZakres (1,00 – 333,3) mg/m3\nZakres (0,03 – 1,00) mg w probce\nZakres (0,33 – 109,9) ppm\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-89/Z-04209.02","categories":["environment"],"row_index":202,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"NN-Dimethylformamide concentration/content","parameters_en":[{"name":"Range","range":"(1,00 – 333,3) mg/m3"},{"name":"Range","range":"(0,03 – 1,00) mg w próbce"},{"name":"Range","range":"(0,33 – 109,9) ppm"}],"search_en":"Workplace environment − air NN-Dimethylformamide concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range Range PN-89/Z-04209.02","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"范围","range":"(1,00 – 333,3) mg/m3"},{"name":"范围","range":"(0,03 – 1,00) mg w próbce"},{"name":"范围","range":"(0,33 – 109,9) ppm"}],"search_zh":"工作环境 − 空气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 范围 PN-89/Z-04209.02","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作环境 − 空气"},{"_id":"6a836fb9af14b9c0e7b1ebe2","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość epoksyetanu","parameters":[{"name":"Zakres","range":"(0,07 – 2,13) mg/m3"},{"name":"Zakres","range":"(0,002 – 0,048) mg w próbce"},{"name":"Zakres","range":"(0,04 – 1,17) ppm"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość epoksyetanu\nZakres:\nZakres (0,07 – 2,13) mg/m3\nZakres (0,002 – 0,048) mg w próbce\nZakres (0,04 – 1,17) ppm\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04300:2002","norm_bases":["PN-Z-04300:2002"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość epoksyetanu\nZakres:\nZakres (0,07 – 2,13) mg/m3\nZakres (0,002 – 0,048) mg w próbce\nZakres (0,04 – 1,17) ppm\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04300:2002 Srodowisko pracy − powietrze Stezenie/zawartosc epoksyetanu\nZakres:\nZakres (0,07 – 2,13) mg/m3\nZakres (0,002 – 0,048) mg w probce\nZakres (0,04 – 1,17) ppm\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04300:2002","categories":["environment"],"row_index":203,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ethylene oxide concentration/content","parameters_en":[{"name":"Range","range":"(0,07 – 2,13) mg/m3"},{"name":"Range","range":"(0,002 – 0,048) mg w próbce"},{"name":"Range","range":"(0,04 – 1,17) ppm"}],"search_en":"Workplace environment − air Ethylene oxide concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range Range PN-Z-04300:2002","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"范围","range":"(0,07 – 2,13) mg/m3"},{"name":"范围","range":"(0,002 – 0,048) mg w próbce"},{"name":"范围","range":"(0,04 – 1,17) ppm"}],"search_zh":"工作环境 − 空气 环氧乙烷的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 范围 PN-Z-04300:2002","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作环境 − 空气","methodology_zh":"环氧乙烷的浓度/含量"},{"_id":"6a836fb9af14b9c0e7b1ebe3","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość benzyny ekstrakcyjnej","parameters":[{"name":"Zakres","range":"(2,08 – 1041,7) mg/m3"},{"name":"Zakres","range":"(0,15 – 7,5) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość benzyny ekstrakcyjnej\nZakres:\nZakres (2,08 – 1041,7) mg/m3\nZakres (0,15 – 7,5) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-81/Z-04134.02","norm_bases":["PN-81/Z-04134.02"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość benzyny ekstrakcyjnej\nZakres:\nZakres (2,08 – 1041,7) mg/m3\nZakres (0,15 – 7,5) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-81/Z-04134.02 Srodowisko pracy − powietrze Stezenie/zawartosc benzyny ekstrakcyjnej\nZakres:\nZakres (2,08 – 1041,7) mg/m3\nZakres (0,15 – 7,5) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-81/Z-04134.02","categories":["environment"],"row_index":204,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Extraction naphtha concentration/content","parameters_en":[{"name":"Range","range":"(2,08 – 1041,7) mg/m3"},{"name":"Range","range":"(0,15 – 7,5) mg w próbce"}],"search_en":"Workplace environment − air Extraction naphtha concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-81/Z-04134.02","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"范围","range":"(2,08 – 1041,7) mg/m3"},{"name":"范围","range":"(0,15 – 7,5) mg w próbce"}],"search_zh":"工作环境 − 空气 抽提汽油的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-81/Z-04134.02","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作环境 − 空气","methodology_zh":"抽提汽油的浓度/含量"},{"_id":"6a836fb9af14b9c0e7b1ebe4","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość fenolu","parameters":[{"name":"Zakres","range":"(0,50 – 35,00) mg/m3"},{"name":"Zakres","range":"(0,002 – 0,070) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość fenolu\nZakres:\nZakres (0,50 – 35,00) mg/m3\nZakres (0,002 – 0,070) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-Z-04044:1970","norm_bases":["PN-Z-04044:1970"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość fenolu\nZakres:\nZakres (0,50 – 35,00) mg/m3\nZakres (0,002 – 0,070) mg w próbce\nMetoda spektrofotometryczna PN-Z-04044:1970 Srodowisko pracy − powietrze Stezenie/zawartosc fenolu\nZakres:\nZakres (0,50 – 35,00) mg/m3\nZakres (0,002 – 0,070) mg w probce\nMetoda spektrofotometryczna PN-Z-04044:1970","categories":["environment"],"row_index":205,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phenol concentration/content","parameters_en":[{"name":"Range","range":"(0,50 – 35,00) mg/m3"},{"name":"Range","range":"(0,002 – 0,070) mg w próbce"}],"search_en":"Workplace environment − air Phenol concentration/content Spectrophotometric method Range Range PN-Z-04044:1970","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"范围","range":"(0,50 – 35,00) mg/m3"},{"name":"范围","range":"(0,002 – 0,070) mg w próbce"}],"search_zh":"工作环境 − 空气 苯酚的浓度/含量 分光光度法 范围 范围 PN-Z-04044:1970","technique_zh":"分光光度法","test_object_zh":"工作环境 − 空气","methodology_zh":"苯酚的浓度/含量"},{"_id":"6a836fb9af14b9c0e7b1ebe5","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie tlenku węgla","parameters":[{"name":"Zakres","range":"(2,3 – 232,4) mg/m3"},{"name":"Zakres","range":"(2,0 – 200,0) ppm"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Stężenie tlenku węgla\nZakres:\nZakres (2,3 – 232,4) mg/m3\nZakres (2,0 – 200,0) ppm\nMetoda elektrochemiczna","reference":"Metoda nr 213 wydanie 1 z dnia 08.09.2025","norm_bases":["Metoda nr 213 wydanie 1 z dnia 08.09.2025"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie tlenku węgla\nZakres:\nZakres (2,3 – 232,4) mg/m3\nZakres (2,0 – 200,0) ppm\nMetoda elektrochemiczna Metoda nr 213 wydanie 1 z dnia 08.09.2025 Srodowisko pracy − powietrze Stezenie tlenku wegla\nZakres:\nZakres (2,3 – 232,4) mg/m3\nZakres (2,0 – 200,0) ppm\nMetoda elektrochemiczna Metoda nr 213 wydanie 1 z dnia 08.09.2025","categories":["environment"],"row_index":206,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Carbon monoxide concentration","parameters_en":[{"name":"Range","range":"(2,3 – 232,4) mg/m3"},{"name":"Range","range":"(2,0 – 200,0) ppm"}],"search_en":"Workplace environment − air Carbon monoxide concentration Electrochemical method Range Range Metoda nr 213 wydanie 1 z dnia 08.09.2025","technique_en":"Electrochemical method","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"范围","range":"(2,3 – 232,4) mg/m3"},{"name":"范围","range":"(2,0 – 200,0) ppm"}],"search_zh":"工作环境 − 空气 一氧化碳浓度 电化学法 范围 范围 Metoda nr 213 wydanie 1 z dnia 08.09.2025","technique_zh":"电化学法","test_object_zh":"工作环境 − 空气","methodology_zh":"一氧化碳浓度"},{"_id":"6a836fb9af14b9c0e7b1ebe6","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Wskaźnik narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"Metoda nr 213 wydanie 1 z dnia 08.09.2025","norm_bases":["Metoda nr 213 wydanie 1 z dnia 08.09.2025"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Wskaźnik narażenia (z obliczeń) Metoda nr 213 wydanie 1 z dnia 08.09.2025 Srodowisko pracy − powietrze Wskaznik narazenia (z obliczen) Metoda nr 213 wydanie 1 z dnia 08.09.2025","categories":["environment"],"row_index":207,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Exposure index (calculated)","search_en":"Workplace environment − air Exposure index (calculated) Metoda nr 213 wydanie 1 z dnia 08.09.2025","test_object_en":"Workplace environment − air","methodology_zh":"暴露指数（计算得出）","search_zh":"工作环境 − 空气 暴露指数（计算得出） Metoda nr 213 wydanie 1 z dnia 08.09.2025","test_object_zh":"工作环境 − 空气"},{"_id":"6a836fb9af14b9c0e7b1ebe7","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość metanolu","parameters":[{"name":"Zakres","range":"(0,05 – 1,0) mg w próbce"},{"name":"Zakres","range":"(10,0 – 666,7) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość metanolu\nZakres:\nZakres (0,05 – 1,0) mg w próbce\nZakres (10,0 – 666,7) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2014, nr 3(81) s 89 – 101","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2014, nr 3(81) s 89 – 101"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość metanolu\nZakres:\nZakres (0,05 – 1,0) mg w próbce\nZakres (10,0 – 666,7) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Podstawy i Metody Oceny Środowiska Pracy 2014, nr 3(81) s 89 – 101 Srodowisko pracy − powietrze Stezenie/zawartosc metanolu\nZakres:\nZakres (0,05 – 1,0) mg w probce\nZakres (10,0 – 666,7) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Podstawy i Metody Oceny Srodowiska Pracy 2014, nr 3(81) s 89 – 101","categories":["environment"],"row_index":208,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Methanol concentration/content","parameters_en":[{"name":"Range","range":"(0,05 – 1,0) mg w próbce"},{"name":"Range","range":"(10,0 – 666,7) mg/m3"}],"search_en":"Workplace environment − air Methanol concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range Podstawy i Metody Oceny Środowiska Pracy 2014, nr 3(81) s 89 – 101","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"范围","range":"(0,05 – 1,0) mg w próbce"},{"name":"范围","range":"(10,0 – 666,7) mg/m3"}],"search_zh":"工作环境 − 空气 甲醇的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 Podstawy i Metody Oceny Środowiska Pracy 2014, nr 3(81) s 89 – 101","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作环境 − 空气","methodology_zh":"甲醇的浓度/含量"},{"_id":"6a836fb9af14b9c0e7b1ebe8","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość propan-2-ol","parameters":[{"name":"Zakres","range":"(11,11 – 2400) mg/m3"},{"name":"Zakres","range":"(0,10 – 16,25) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość propan-2-ol\nZakres:\nZakres (11,11 – 2400) mg/m3\nZakres (0,10 – 16,25) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2020, nr 1(103) s 159 – 169","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2020, nr 1(103) s 159 – 169"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość propan-2-ol\nZakres:\nZakres (11,11 – 2400) mg/m3\nZakres (0,10 – 16,25) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Podstawy i Metody Oceny Środowiska Pracy 2020, nr 1(103) s 159 – 169 Srodowisko pracy − powietrze Stezenie/zawartosc propan-2-ol\nZakres:\nZakres (11,11 – 2400) mg/m3\nZakres (0,10 – 16,25) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Podstawy i Metody Oceny Srodowiska Pracy 2020, nr 1(103) s 159 – 169","categories":["environment"],"row_index":209,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(11,11 – 2400) mg/m3"},{"name":"Range","range":"(0,10 – 16,25) mg w próbce"}],"search_en":"Workplace environment − air Gas chromatography with flame ionization detection (GC-FID) Range Range Podstawy i Metody Oceny Środowiska Pracy 2020, nr 1(103) s 159 – 169","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"范围","range":"(11,11 – 2400) mg/m3"},{"name":"范围","range":"(0,10 – 16,25) mg w próbce"}],"search_zh":"工作环境 − 空气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 Podstawy i Metody Oceny Środowiska Pracy 2020, nr 1(103) s 159 – 169","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作环境 − 空气"},{"_id":"6a836fb9af14b9c0e7b1ebe9","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość olejów mineralnych wysokorafinowanych, z wyłączeniem cieczy obróbkowych","parameters":[{"name":"Zakres","range":"(0,14 – 10,00) mg/m3"},{"name":"Zakres","range":"(0,100 – 7,200) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość olejów mineralnych wysokorafinowanych, z wyłączeniem cieczy obróbkowych\nZakres:\nZakres (0,14 – 10,00) mg/m3\nZakres (0,100 – 7,200) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-Z-04108-06:2006+Az1:2009","norm_bases":["PN-Z-04108-06:2006+Az1:2009"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość olejów mineralnych wysokorafinowanych, z wyłączeniem cieczy obróbkowych\nZakres:\nZakres (0,14 – 10,00) mg/m3\nZakres (0,100 – 7,200) mg w próbce\nMetoda spektrofotometryczna PN-Z-04108-06:2006+Az1:2009 Srodowisko pracy − powietrze Stezenie/zawartosc olejow mineralnych wysokorafinowanych, z wylaczeniem cieczy obrobkowych\nZakres:\nZakres (0,14 – 10,00) mg/m3\nZakres (0,100 – 7,200) mg w probce\nMetoda spektrofotometryczna PN-Z-04108-06:2006+Az1:2009","categories":["environment","petro"],"row_index":210,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,14 – 10,00) mg/m3"},{"name":"Range","range":"(0,100 – 7,200) mg w próbce"}],"search_en":"Workplace environment − air Spectrophotometric method Range Range PN-Z-04108-06:2006+Az1:2009","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"范围","range":"(0,14 – 10,00) mg/m3"},{"name":"范围","range":"(0,100 – 7,200) mg w próbce"}],"search_zh":"工作环境 − 空气 分光光度法 范围 范围 PN-Z-04108-06:2006+Az1:2009","technique_zh":"分光光度法","test_object_zh":"工作环境 − 空气"},{"_id":"6a836fb9af14b9c0e7b1ebea","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze *)","methodology":"Stężenie substancji organicznych*)","parameters":[{"name":"butan","range":"(380 – 3800) mg/m3"},{"name":"propan","range":"(288 – 2880) mg/m3"},{"name":"izobutan","range":"(380 – 3800) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie substancji organicznych*)\nZakres:\nbutan (380 – 3800) mg/m3\npropan (288 – 2880) mg/m3\nizobutan (380 – 3800) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Metoda nr 045 wydanie 2 z dnia 14.02.2017","norm_bases":["Metoda nr 045 wydanie 2 z dnia 14.02.2017"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze *) Stężenie substancji organicznych*)\nZakres:\nbutan (380 – 3800) mg/m3\npropan (288 – 2880) mg/m3\nizobutan (380 – 3800) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Metoda nr 045 wydanie 2 z dnia 14.02.2017 Srodowisko pracy − powietrze *) Stezenie substancji organicznych*)\nZakres:\nbutan (380 – 3800) mg/m3\npropan (288 – 2880) mg/m3\nizobutan (380 – 3800) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Metoda nr 045 wydanie 2 z dnia 14.02.2017","categories":["environment"],"row_index":211,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"butane","range":"(380 – 3800) mg/m3"},{"name":"propane","range":"(288 – 2880) mg/m3"},{"name":"isobutane","range":"(380 – 3800) mg/m3"}],"search_en":"Gas chromatography with flame ionization detection (GC-FID) butane propane isobutane Metoda nr 045 wydanie 2 z dnia 14.02.2017","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） 丙烷 Metoda nr 045 wydanie 2 z dnia 14.02.2017","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","parameters_zh":[{"name":"butan","range":"(380 – 3800) mg/m3"},{"name":"丙烷","range":"(288 – 2880) mg/m3"},{"name":"izobutan","range":"(380 – 3800) mg/m3"}]},{"_id":"6a836fb9af14b9c0e7b1ebeb","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość substancji organicznych","parameters":[{"name":"Aceton (0,1 – 10) mg w próbce"},{"name":"Zakres","range":"(3,33 – 3333,3) mg/m3"},{"name":"Butan-2-on (0,036 – 9,0) mg w próbce","range":"(3,00 – 1800,0) mg/m3"},{"name":"Butan","range":"(0,78 – 3888,9) mg/m3"},{"name":"(0,056 – 7,000) mg w próbce Etylobenzen (0,016 – 4,0) mg w próbce","range":"(1,33 – 800) mg/m3"},{"name":"Benzen (0,0015 – 0,15) mg w próbce","range":"(0,05 – 5,0) mg/m3"},{"name":"(0,02 – 1,54) ppm"},{"name":"Heksan (0,008 – 2,0) mg w próbce","range":"(0,67 – 200,0) mg/m3"},{"name":"Cykloheksan (0,028 – 7,0) mg w próbce","range":"(2,33 – 2333,3) mg/m3"},{"name":"Metylocykloheksan (0,040 – 10,0) mg w próbce","range":"(3,33 – 6666,7) mg/m3"},{"name":"Heptan (0,040 – 10,0) mg w próbce","range":"(3,33 – 4000,0) mg/m3"},{"name":"Ksylen - mieszanina izomerów","range":"(1,2-; 1,3-; 1,4-)"},{"name":"(0,008 – 2,0) mg w próbce","range":"(0,67 – 666,7) mg/m3"},{"name":"Kumen (0,008 – 2,0) mg w próbce","range":"(0,67 – 666,7) mg/m3"},{"name":"Oktan (0,040 – 10,0) mg w próbce","range":"(3,33 – 4000,0) mg/m3"},{"name":"Toluen (0,080 – 2,0) mg w próbce","range":"(0,67 – 66,7) mg/m3"},{"name":"Etanol (0,1 – 10) mg w próbce","range":"(3,33 – 3333,3) mg/m3"},{"name":"Izopentan (0,04 – 10) mg w próbce","range":"(3,33 – 6666,7) mg/m3"},{"name":"Pentan (0,04 – 10) mg w próbce","range":"(3,33 – 6666,7) mg/m3"},{"name":"Eter tert-butylometylowy (0,008 – 4) mg w próbce","range":"(1,33 – 800,0) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość substancji organicznych\nZakres:\nAceton (0,1 – 10) mg w próbce\nZakres (3,33 – 3333,3) mg/m3\nButan-2-on (0,036 – 9,0) mg w próbce (3,00 – 1800,0) mg/m3\nButan (0,78 – 3888,9) mg/m3\n(0,056 – 7,000) mg w próbce Etylobenzen (0,016 – 4,0) mg w próbce (1,33 – 800) mg/m3\nBenzen (0,0015 – 0,15) mg w próbce (0,05 – 5,0) mg/m3\n(0,02 – 1,54) ppm\nHeksan (0,008 – 2,0) mg w próbce (0,67 – 200,0) mg/m3\nCykloheksan (0,028 – 7,0) mg w próbce (2,33 – 2333,3) mg/m3\nMetylocykloheksan (0,040 – 10,0) mg w próbce (3,33 – 6666,7) mg/m3\nHeptan (0,040 – 10,0) mg w próbce (3,33 – 4000,0) mg/m3\nKsylen - mieszanina izomerów (1,2-; 1,3-; 1,4-)\n(0,008 – 2,0) mg w próbce (0,67 – 666,7) mg/m3\nKumen (0,008 – 2,0) mg w próbce (0,67 – 666,7) mg/m3\nOktan (0,040 – 10,0) mg w próbce (3,33 – 4000,0) mg/m3\nToluen (0,080 – 2,0) mg w próbce (0,67 – 66,7) mg/m3\nEtanol (0,1 – 10) mg w próbce (3,33 – 3333,3) mg/m3\nIzopentan (0,04 – 10) mg w próbce (3,33 – 6666,7) mg/m3\nPentan (0,04 – 10) mg w próbce (3,33 – 6666,7) mg/m3\nEter tert-butylometylowy (0,008 – 4) mg w próbce (1,33 – 800,0) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Metoda nr 031 Wydanie 5 z dnia 20.02.2026","norm_bases":["Metoda nr 031 Wydanie 5 z dnia 20.02.2026"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość substancji organicznych\nZakres:\nAceton (0,1 – 10) mg w próbce\nZakres (3,33 – 3333,3) mg/m3\nButan-2-on (0,036 – 9,0) mg w próbce (3,00 – 1800,0) mg/m3\nButan (0,78 – 3888,9) mg/m3\n(0,056 – 7,000) mg w próbce Etylobenzen (0,016 – 4,0) mg w próbce (1,33 – 800) mg/m3\nBenzen (0,0015 – 0,15) mg w próbce (0,05 – 5,0) mg/m3\n(0,02 – 1,54) ppm\nHeksan (0,008 – 2,0) mg w próbce (0,67 – 200,0) mg/m3\nCykloheksan (0,028 – 7,0) mg w próbce (2,33 – 2333,3) mg/m3\nMetylocykloheksan (0,040 – 10,0) mg w próbce (3,33 – 6666,7) mg/m3\nHeptan (0,040 – 10,0) mg w próbce (3,33 – 4000,0) mg/m3\nKsylen - mieszanina izomerów (1,2-; 1,3-; 1,4-)\n(0,008 – 2,0) mg w próbce (0,67 – 666,7) mg/m3\nKumen (0,008 – 2,0) mg w próbce (0,67 – 666,7) mg/m3\nOktan (0,040 – 10,0) mg w próbce (3,33 – 4000,0) mg/m3\nToluen (0,080 – 2,0) mg w próbce (0,67 – 66,7) mg/m3\nEtanol (0,1 – 10) mg w próbce (3,33 – 3333,3) mg/m3\nIzopentan (0,04 – 10) mg w próbce (3,33 – 6666,7) mg/m3\nPentan (0,04 – 10) mg w próbce (3,33 – 6666,7) mg/m3\nEter tert-butylometylowy (0,008 – 4) mg w próbce (1,33 – 800,0) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Metoda nr 031 Wydanie 5 z dnia 20.02.2026 Srodowisko pracy − powietrze Stezenie/zawartosc substancji organicznych\nZakres:\nAceton (0,1 – 10) mg w probce\nZakres (3,33 – 3333,3) mg/m3\nButan-2-on (0,036 – 9,0) mg w probce (3,00 – 1800,0) mg/m3\nButan (0,78 – 3888,9) mg/m3\n(0,056 – 7,000) mg w probce Etylobenzen (0,016 – 4,0) mg w probce (1,33 – 800) mg/m3\nBenzen (0,0015 – 0,15) mg w probce (0,05 – 5,0) mg/m3\n(0,02 – 1,54) ppm\nHeksan (0,008 – 2,0) mg w probce (0,67 – 200,0) mg/m3\nCykloheksan (0,028 – 7,0) mg w probce (2,33 – 2333,3) mg/m3\nMetylocykloheksan (0,040 – 10,0) mg w probce (3,33 – 6666,7) mg/m3\nHeptan (0,040 – 10,0) mg w probce (3,33 – 4000,0) mg/m3\nKsylen - mieszanina izomerow (1,2-; 1,3-; 1,4-)\n(0,008 – 2,0) mg w probce (0,67 – 666,7) mg/m3\nKumen (0,008 – 2,0) mg w probce (0,67 – 666,7) mg/m3\nOktan (0,040 – 10,0) mg w probce (3,33 – 4000,0) mg/m3\nToluen (0,080 – 2,0) mg w probce (0,67 – 66,7) mg/m3\nEtanol (0,1 – 10) mg w probce (3,33 – 3333,3) mg/m3\nIzopentan (0,04 – 10) mg w probce (3,33 – 6666,7) mg/m3\nPentan (0,04 – 10) mg w probce (3,33 – 6666,7) mg/m3\nEter tert-butylometylowy (0,008 – 4) mg w probce (1,33 – 800,0) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Metoda nr 031 Wydanie 5 z dnia 20.02.2026","categories":["environment"],"row_index":212,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of organic substances","parameters_en":[{"name":"Aceton (0,1 – 10) mg w próbce"},{"name":"Range","range":"(3,33 – 3333,3) mg/m3"},{"name":"Butan-2-on (0,036 – 9,0) mg w próbce","range":"(3,00 – 1800,0) mg/m3"},{"name":"Butane","range":"(0,78 – 3888,9) mg/m3"},{"name":"(0,056 – 7,000) mg w próbce Etylobenzen (0,016 – 4,0) mg w próbce","range":"(1,33 – 800) mg/m3"},{"name":"Benzen (0,0015 – 0,15) mg w próbce","range":"(0,05 – 5,0) mg/m3"},{"name":"(0,02 – 1,54) ppm"},{"name":"Heksan (0,008 – 2,0) mg w próbce","range":"(0,67 – 200,0) mg/m3"},{"name":"Cykloheksan (0,028 – 7,0) mg w próbce","range":"(2,33 – 2333,3) mg/m3"},{"name":"Metylocykloheksan (0,040 – 10,0) mg w próbce","range":"(3,33 – 6666,7) mg/m3"},{"name":"Heptan (0,040 – 10,0) mg w próbce","range":"(3,33 – 4000,0) mg/m3"},{"name":"Xylene - mixture of isomers","range":"(1,2-; 1,3-; 1,4-)"},{"name":"(0,008 – 2,0) mg w próbce","range":"(0,67 – 666,7) mg/m3"},{"name":"Kumen (0,008 – 2,0) mg w próbce","range":"(0,67 – 666,7) mg/m3"},{"name":"Oktan (0,040 – 10,0) mg w próbce","range":"(3,33 – 4000,0) mg/m3"},{"name":"Toluen (0,080 – 2,0) mg w próbce","range":"(0,67 – 66,7) mg/m3"},{"name":"Etanol (0,1 – 10) mg w próbce","range":"(3,33 – 3333,3) mg/m3"},{"name":"Izopentan (0,04 – 10) mg w próbce","range":"(3,33 – 6666,7) mg/m3"},{"name":"Pentan (0,04 – 10) mg w próbce","range":"(3,33 – 6666,7) mg/m3"},{"name":"Eter tert-butylometylowy (0,008 – 4) mg w próbce","range":"(1,33 – 800,0) mg/m3"}],"search_en":"Workplace environment − air Concentration/content of organic substances Gas chromatography with flame ionization detection (GC-FID) Range Butane Xylene - mixture of isomers Metoda nr 031 Wydanie 5 z dnia 20.02.2026","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"Aceton (0,1 – 10) mg w próbce"},{"name":"范围","range":"(3,33 – 3333,3) mg/m3"},{"name":"Butan-2-on (0,036 – 9,0) mg w próbce","range":"(3,00 – 1800,0) mg/m3"},{"name":"Butan","range":"(0,78 – 3888,9) mg/m3"},{"name":"(0,056 – 7,000) mg w próbce Etylobenzen (0,016 – 4,0) mg w próbce","range":"(1,33 – 800) mg/m3"},{"name":"Benzen (0,0015 – 0,15) mg w próbce","range":"(0,05 – 5,0) mg/m3"},{"name":"(0,02 – 1,54) ppm"},{"name":"Heksan (0,008 – 2,0) mg w próbce","range":"(0,67 – 200,0) mg/m3"},{"name":"Cykloheksan (0,028 – 7,0) mg w próbce","range":"(2,33 – 2333,3) mg/m3"},{"name":"Metylocykloheksan (0,040 – 10,0) mg w próbce","range":"(3,33 – 6666,7) mg/m3"},{"name":"Heptan (0,040 – 10,0) mg w próbce","range":"(3,33 – 4000,0) mg/m3"},{"name":"二甲苯 － 异构体混合物","range":"(1,2-; 1,3-; 1,4-)"},{"name":"(0,008 – 2,0) mg w próbce","range":"(0,67 – 666,7) mg/m3"},{"name":"Kumen (0,008 – 2,0) mg w próbce","range":"(0,67 – 666,7) mg/m3"},{"name":"Oktan (0,040 – 10,0) mg w próbce","range":"(3,33 – 4000,0) mg/m3"},{"name":"Toluen (0,080 – 2,0) mg w próbce","range":"(0,67 – 66,7) mg/m3"},{"name":"Etanol (0,1 – 10) mg w próbce","range":"(3,33 – 3333,3) mg/m3"},{"name":"Izopentan (0,04 – 10) mg w próbce","range":"(3,33 – 6666,7) mg/m3"},{"name":"Pentan (0,04 – 10) mg w próbce","range":"(3,33 – 6666,7) mg/m3"},{"name":"Eter tert-butylometylowy (0,008 – 4) mg w próbce","range":"(1,33 – 800,0) mg/m3"}],"search_zh":"工作环境 − 空气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 二甲苯 － 异构体混合物 Metoda nr 031 Wydanie 5 z dnia 20.02.2026","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作环境 − 空气"},{"_id":"6a836fb9af14b9c0e7b1ebec","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość chloru","parameters":[{"name":"Zakres","range":"(0,05 – 5,00) mg/m3"},{"name":"Zakres","range":"(0,0002 – 0,0050) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość chloru\nZakres:\nZakres (0,05 – 5,00) mg/m3\nZakres (0,0002 – 0,0050) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-75/Z-04037/03","norm_bases":["PN-75/Z-04037/03"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość chloru\nZakres:\nZakres (0,05 – 5,00) mg/m3\nZakres (0,0002 – 0,0050) mg w próbce\nMetoda spektrofotometryczna PN-75/Z-04037/03 Srodowisko pracy − powietrze Stezenie/zawartosc chloru\nZakres:\nZakres (0,05 – 5,00) mg/m3\nZakres (0,0002 – 0,0050) mg w probce\nMetoda spektrofotometryczna PN-75/Z-04037/03","categories":["environment"],"row_index":213,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chlorine concentration/content","parameters_en":[{"name":"Range","range":"(0,05 – 5,00) mg/m3"},{"name":"Range","range":"(0,0002 – 0,0050) mg w próbce"}],"search_en":"Workplace environment − air Chlorine concentration/content Spectrophotometric method Range Range PN-75/Z-04037/03","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"范围","range":"(0,05 – 5,00) mg/m3"},{"name":"范围","range":"(0,0002 – 0,0050) mg w próbce"}],"search_zh":"工作环境 − 空气 氯的浓度/含量 分光光度法 范围 范围 PN-75/Z-04037/03","technique_zh":"分光光度法","test_object_zh":"工作环境 − 空气","methodology_zh":"氯的浓度/含量"},{"_id":"6a836fb9af14b9c0e7b1ebed","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość amoniaku","parameters":[{"name":"Zakres","range":"(1,20 – 60,00) mg/m3"},{"name":"Zakres","range":"(0,006 – 0,300) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość amoniaku\nZakres:\nZakres (1,20 – 60,00) mg/m3\nZakres (0,006 – 0,300) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-71/Z-04041","norm_bases":["PN-71/Z-04041"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość amoniaku\nZakres:\nZakres (1,20 – 60,00) mg/m3\nZakres (0,006 – 0,300) mg w próbce\nMetoda spektrofotometryczna PN-71/Z-04041 Srodowisko pracy − powietrze Stezenie/zawartosc amoniaku\nZakres:\nZakres (1,20 – 60,00) mg/m3\nZakres (0,006 – 0,300) mg w probce\nMetoda spektrofotometryczna PN-71/Z-04041","categories":["environment"],"row_index":214,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonia concentration/content","parameters_en":[{"name":"Range","range":"(1,20 – 60,00) mg/m3"},{"name":"Range","range":"(0,006 – 0,300) mg w próbce"}],"search_en":"Workplace environment − air Ammonia concentration/content Spectrophotometric method Range Range PN-71/Z-04041","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"范围","range":"(1,20 – 60,00) mg/m3"},{"name":"范围","range":"(0,006 – 0,300) mg w próbce"}],"search_zh":"工作环境 − 空气 氨浓度/含量 分光光度法 范围 范围 PN-71/Z-04041","technique_zh":"分光光度法","test_object_zh":"工作环境 − 空气","methodology_zh":"氨浓度/含量"},{"_id":"6a836fb9af14b9c0e7b1ebee","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość fluorowodoru","parameters":[{"name":"Zakres","range":"(0,15 – 2,25) mg/m3"},{"name":"Zakres","range":"(0,008 – 0,113) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość fluorowodoru\nZakres:\nZakres (0,15 – 2,25) mg/m3\nZakres (0,008 – 0,113) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-82/Z-04093.03","norm_bases":["PN-82/Z-04093.03"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość fluorowodoru\nZakres:\nZakres (0,15 – 2,25) mg/m3\nZakres (0,008 – 0,113) mg w próbce\nMetoda spektrofotometryczna PN-82/Z-04093.03 Srodowisko pracy − powietrze Stezenie/zawartosc fluorowodoru\nZakres:\nZakres (0,15 – 2,25) mg/m3\nZakres (0,008 – 0,113) mg w probce\nMetoda spektrofotometryczna PN-82/Z-04093.03","categories":["environment"],"row_index":215,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrogen fluoride concentration/content","parameters_en":[{"name":"Range","range":"(0,15 – 2,25) mg/m3"},{"name":"Range","range":"(0,008 – 0,113) mg w próbce"}],"search_en":"Workplace environment − air Hydrogen fluoride concentration/content Spectrophotometric method Range Range PN-82/Z-04093.03","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"范围","range":"(0,15 – 2,25) mg/m3"},{"name":"范围","range":"(0,008 – 0,113) mg w próbce"}],"search_zh":"工作环境 − 空气 氟化氢的浓度/含量 分光光度法 范围 范围 PN-82/Z-04093.03","technique_zh":"分光光度法","test_object_zh":"工作环境 − 空气","methodology_zh":"氟化氢的浓度/含量"},{"_id":"6a836fb9af14b9c0e7b1ebef","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość formaldehydu","parameters":[{"name":"Zakres","range":"(0,048 – 5,33) mg/m3"},{"name":"Zakres","range":"(0,0008 – 0,040) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość formaldehydu\nZakres:\nZakres (0,048 – 5,33) mg/m3\nZakres (0,0008 – 0,040) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-76/Z-04045.02","norm_bases":["PN-76/Z-04045.02"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość formaldehydu\nZakres:\nZakres (0,048 – 5,33) mg/m3\nZakres (0,0008 – 0,040) mg w próbce\nMetoda spektrofotometryczna PN-76/Z-04045.02 Srodowisko pracy − powietrze Stezenie/zawartosc formaldehydu\nZakres:\nZakres (0,048 – 5,33) mg/m3\nZakres (0,0008 – 0,040) mg w probce\nMetoda spektrofotometryczna PN-76/Z-04045.02","categories":["environment"],"row_index":216,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Formaldehyde concentration/content","parameters_en":[{"name":"Range","range":"(0,048 – 5,33) mg/m3"},{"name":"Range","range":"(0,0008 – 0,040) mg w próbce"}],"search_en":"Workplace environment − air Formaldehyde concentration/content Spectrophotometric method Range Range PN-76/Z-04045.02","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"范围","range":"(0,048 – 5,33) mg/m3"},{"name":"范围","range":"(0,0008 – 0,040) mg w próbce"}],"search_zh":"工作环境 − 空气 甲醛浓度/含量 分光光度法 范围 范围 PN-76/Z-04045.02","technique_zh":"分光光度法","test_object_zh":"工作环境 − 空气","methodology_zh":"甲醛浓度/含量"},{"_id":"6a836fb9af14b9c0e7b1ebf0","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość 2-furaldehydu","parameters":[{"name":"Zakres","range":"(1,00 – 50,00) mg/m3"},{"name":"Zakres","range":"(0,005 – 0,250) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość 2-furaldehydu\nZakres:\nZakres (1,00 – 50,00) mg/m3\nZakres (0,005 – 0,250) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-71/Z-04058","norm_bases":["PN-71/Z-04058"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość 2-furaldehydu\nZakres:\nZakres (1,00 – 50,00) mg/m3\nZakres (0,005 – 0,250) mg w próbce\nMetoda spektrofotometryczna PN-71/Z-04058 Srodowisko pracy − powietrze Stezenie/zawartosc 2-furaldehydu\nZakres:\nZakres (1,00 – 50,00) mg/m3\nZakres (0,005 – 0,250) mg w probce\nMetoda spektrofotometryczna PN-71/Z-04058","categories":["environment"],"row_index":217,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of 2-furaldehyde","parameters_en":[{"name":"Range","range":"(1,00 – 50,00) mg/m3"},{"name":"Range","range":"(0,005 – 0,250) mg w próbce"}],"search_en":"Workplace environment − air Concentration/content of 2-furaldehyde Spectrophotometric method Range Range PN-71/Z-04058","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"范围","range":"(1,00 – 50,00) mg/m3"},{"name":"范围","range":"(0,005 – 0,250) mg w próbce"}],"search_zh":"工作环境 − 空气 分光光度法 范围 范围 PN-71/Z-04058","technique_zh":"分光光度法","test_object_zh":"工作环境 − 空气"},{"_id":"6a836fb9af14b9c0e7b1ebf1","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość ozonu","parameters":[{"name":"Zakres","range":"(0,0125 – 0,3000) mg/m3"},{"name":"Zakres","range":"(0,0005 – 0,0120) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość ozonu\nZakres:\nZakres (0,0125 – 0,3000) mg/m3\nZakres (0,0005 – 0,0120) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-Z-04007-2:1994","norm_bases":["PN-Z-04007-2:1994"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość ozonu\nZakres:\nZakres (0,0125 – 0,3000) mg/m3\nZakres (0,0005 – 0,0120) mg w próbce\nMetoda spektrofotometryczna PN-Z-04007-2:1994 Srodowisko pracy − powietrze Stezenie/zawartosc ozonu\nZakres:\nZakres (0,0125 – 0,3000) mg/m3\nZakres (0,0005 – 0,0120) mg w probce\nMetoda spektrofotometryczna PN-Z-04007-2:1994","categories":["environment"],"row_index":218,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ozone concentration/content","parameters_en":[{"name":"Range","range":"(0,0125 – 0,3000) mg/m3"},{"name":"Range","range":"(0,0005 – 0,0120) mg w próbce"}],"search_en":"Workplace environment − air Ozone concentration/content Spectrophotometric method Range Range PN-Z-04007-2:1994","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"范围","range":"(0,0125 – 0,3000) mg/m3"},{"name":"范围","range":"(0,0005 – 0,0120) mg w próbce"}],"search_zh":"工作环境 − 空气 臭氧的浓度/含量 分光光度法 范围 范围 PN-Z-04007-2:1994","technique_zh":"分光光度法","test_object_zh":"工作环境 − 空气","methodology_zh":"臭氧的浓度/含量"},{"_id":"6a836fb9af14b9c0e7b1ebf2","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość tlenku azotu","parameters":[{"name":"Zakres","range":"(0,22 – 23,1) mg/m3"},{"name":"Zakres","range":"(0,18 – 18,6) ppm"},{"name":"Zakres","range":"(0,001 – 0,104) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość tlenku azotu\nZakres:\nZakres (0,22 – 23,1) mg/m3\nZakres (0,18 – 18,6) ppm\nZakres (0,001 – 0,104) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-Z-04009-11:2008","norm_bases":["PN-Z-04009-11:2008"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość tlenku azotu\nZakres:\nZakres (0,22 – 23,1) mg/m3\nZakres (0,18 – 18,6) ppm\nZakres (0,001 – 0,104) mg w próbce\nMetoda spektrofotometryczna PN-Z-04009-11:2008 Srodowisko pracy − powietrze Stezenie/zawartosc tlenku azotu\nZakres:\nZakres (0,22 – 23,1) mg/m3\nZakres (0,18 – 18,6) ppm\nZakres (0,001 – 0,104) mg w probce\nMetoda spektrofotometryczna PN-Z-04009-11:2008","categories":["environment"],"row_index":219,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrogen monoxide concentration/content","parameters_en":[{"name":"Range","range":"(0,22 – 23,1) mg/m3"},{"name":"Range","range":"(0,18 – 18,6) ppm"},{"name":"Range","range":"(0,001 – 0,104) mg w próbce"}],"search_en":"Workplace environment − air Nitrogen monoxide concentration/content Spectrophotometric method Range Range Range PN-Z-04009-11:2008","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"范围","range":"(0,22 – 23,1) mg/m3"},{"name":"范围","range":"(0,18 – 18,6) ppm"},{"name":"范围","range":"(0,001 – 0,104) mg w próbce"}],"search_zh":"工作环境 − 空气 一氧化氮的浓度/含量 分光光度法 范围 范围 范围 PN-Z-04009-11:2008","technique_zh":"分光光度法","test_object_zh":"工作环境 − 空气","methodology_zh":"一氧化氮的浓度/含量"},{"_id":"6a836fb9af14b9c0e7b1ebf3","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość ditlenku azotu","parameters":[{"name":"Zakres","range":"(0,07 – 3,56) mg/m3"},{"name":"Zakres","range":"(0,0003 – 0,016) mg w próbce"},{"name":"Zakres","range":"(0,04 – 1,86) ppm"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość ditlenku azotu\nZakres:\nZakres (0,07 – 3,56) mg/m3\nZakres (0,0003 – 0,016) mg w próbce\nZakres (0,04 – 1,86) ppm\nMetoda spektrofotometryczna","reference":"PN-Z-04009-11:2008","norm_bases":["PN-Z-04009-11:2008"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość ditlenku azotu\nZakres:\nZakres (0,07 – 3,56) mg/m3\nZakres (0,0003 – 0,016) mg w próbce\nZakres (0,04 – 1,86) ppm\nMetoda spektrofotometryczna PN-Z-04009-11:2008 Srodowisko pracy − powietrze Stezenie/zawartosc ditlenku azotu\nZakres:\nZakres (0,07 – 3,56) mg/m3\nZakres (0,0003 – 0,016) mg w probce\nZakres (0,04 – 1,86) ppm\nMetoda spektrofotometryczna PN-Z-04009-11:2008","categories":["environment"],"row_index":220,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrogen dioxide concentration/content","parameters_en":[{"name":"Range","range":"(0,07 – 3,56) mg/m3"},{"name":"Range","range":"(0,0003 – 0,016) mg w próbce"},{"name":"Range","range":"(0,04 – 1,86) ppm"}],"search_en":"Workplace environment − air Nitrogen dioxide concentration/content Spectrophotometric method Range Range Range PN-Z-04009-11:2008","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"范围","range":"(0,07 – 3,56) mg/m3"},{"name":"范围","range":"(0,0003 – 0,016) mg w próbce"},{"name":"范围","range":"(0,04 – 1,86) ppm"}],"search_zh":"工作环境 − 空气 二氧化氮的浓度/含量 分光光度法 范围 范围 范围 PN-Z-04009-11:2008","technique_zh":"分光光度法","test_object_zh":"工作环境 − 空气","methodology_zh":"二氧化氮的浓度/含量"},{"_id":"6a836fb9af14b9c0e7b1ebf4","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość ditlenku siarki","parameters":[{"name":"Zakres","range":"(0,12 – 6,00) mg/m3"},{"name":"Zakres","range":"(0,0012 – 0,0600) mg w próbce"},{"name":"Zakres","range":"(0,05 – 2,26) ppm"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość ditlenku siarki\nZakres:\nZakres (0,12 – 6,00) mg/m3\nZakres (0,0012 – 0,0600) mg w próbce\nZakres (0,05 – 2,26) ppm\nMetoda spektrofotometryczna","reference":"PN-Z-04015-12:1996+Ap1:2001","norm_bases":["PN-Z-04015-12:1996+Ap1:2001"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość ditlenku siarki\nZakres:\nZakres (0,12 – 6,00) mg/m3\nZakres (0,0012 – 0,0600) mg w próbce\nZakres (0,05 – 2,26) ppm\nMetoda spektrofotometryczna PN-Z-04015-12:1996+Ap1:2001 Srodowisko pracy − powietrze Stezenie/zawartosc ditlenku siarki\nZakres:\nZakres (0,12 – 6,00) mg/m3\nZakres (0,0012 – 0,0600) mg w probce\nZakres (0,05 – 2,26) ppm\nMetoda spektrofotometryczna PN-Z-04015-12:1996+Ap1:2001","categories":["environment"],"row_index":221,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulphur dioxide concentration/content","parameters_en":[{"name":"Range","range":"(0,12 – 6,00) mg/m3"},{"name":"Range","range":"(0,0012 – 0,0600) mg w próbce"},{"name":"Range","range":"(0,05 – 2,26) ppm"}],"search_en":"Workplace environment − air Sulphur dioxide concentration/content Spectrophotometric method Range Range Range PN-Z-04015-12:1996+Ap1:2001","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"范围","range":"(0,12 – 6,00) mg/m3"},{"name":"范围","range":"(0,0012 – 0,0600) mg w próbce"},{"name":"范围","range":"(0,05 – 2,26) ppm"}],"search_zh":"工作环境 − 空气 二氧化硫的浓度/含量 分光光度法 范围 范围 范围 PN-Z-04015-12:1996+Ap1:2001","technique_zh":"分光光度法","test_object_zh":"工作环境 − 空气","methodology_zh":"二氧化硫的浓度/含量"},{"_id":"6a836fb9af14b9c0e7b1ebf5","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość disiarczku węgla","parameters":[{"name":"Zakres","range":"(1,0 – 14,0) mg/m3"},{"name":"Zakres","range":"(0,010 – 0,140) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość disiarczku węgla\nZakres:\nZakres (1,0 – 14,0) mg/m3\nZakres (0,010 – 0,140) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-85/Z-04015.10","norm_bases":["PN-85/Z-04015.10"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość disiarczku węgla\nZakres:\nZakres (1,0 – 14,0) mg/m3\nZakres (0,010 – 0,140) mg w próbce\nMetoda spektrofotometryczna PN-85/Z-04015.10 Srodowisko pracy − powietrze Stezenie/zawartosc disiarczku wegla\nZakres:\nZakres (1,0 – 14,0) mg/m3\nZakres (0,010 – 0,140) mg w probce\nMetoda spektrofotometryczna PN-85/Z-04015.10","categories":["environment"],"row_index":222,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of carbon disulphide","parameters_en":[{"name":"Range","range":"(1,0 – 14,0) mg/m3"},{"name":"Range","range":"(0,010 – 0,140) mg w próbce"}],"search_en":"Workplace environment − air Concentration/content of carbon disulphide Spectrophotometric method Range Range PN-85/Z-04015.10","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"范围","range":"(1,0 – 14,0) mg/m3"},{"name":"范围","range":"(0,010 – 0,140) mg w próbce"}],"search_zh":"工作环境 − 空气 分光光度法 范围 范围 PN-85/Z-04015.10","technique_zh":"分光光度法","test_object_zh":"工作环境 − 空气"},{"_id":"6a836fb9af14b9c0e7b1ebf6","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość siarkowodoru","parameters":[{"name":"Zakres","range":"(0,20 – 28,00) mg/m3"},{"name":"Zakres","range":"(0,002 – 0,280) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość siarkowodoru\nZakres:\nZakres (0,20 – 28,00) mg/m3\nZakres (0,002 – 0,280) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-Z-04015-13:1996","norm_bases":["PN-Z-04015-13:1996"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość siarkowodoru\nZakres:\nZakres (0,20 – 28,00) mg/m3\nZakres (0,002 – 0,280) mg w próbce\nMetoda spektrofotometryczna PN-Z-04015-13:1996 Srodowisko pracy − powietrze Stezenie/zawartosc siarkowodoru\nZakres:\nZakres (0,20 – 28,00) mg/m3\nZakres (0,002 – 0,280) mg w probce\nMetoda spektrofotometryczna PN-Z-04015-13:1996","categories":["environment"],"row_index":223,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrogen sulphide concentration/content","parameters_en":[{"name":"Range","range":"(0,20 – 28,00) mg/m3"},{"name":"Range","range":"(0,002 – 0,280) mg w próbce"}],"search_en":"Workplace environment − air Hydrogen sulphide concentration/content Spectrophotometric method Range Range PN-Z-04015-13:1996","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"范围","range":"(0,20 – 28,00) mg/m3"},{"name":"范围","range":"(0,002 – 0,280) mg w próbce"}],"search_zh":"工作环境 − 空气 硫化氢的浓度/含量 分光光度法 范围 范围 PN-Z-04015-13:1996","technique_zh":"分光光度法","test_object_zh":"工作环境 − 空气","methodology_zh":"硫化氢的浓度/含量"},{"_id":"6a836fb9af14b9c0e7b1ebf7","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość związków chromu (VI) - w przeliczeniu na Cr (VI)","parameters":[{"name":"Zakres","range":"(0,00038 – 0,011) mg/m3"},{"name":"Zakres","range":"(0,0008 – 0,021) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość związków chromu (VI) - w przeliczeniu na Cr (VI)\nZakres:\nZakres (0,00038 – 0,011) mg/m3\nZakres (0,0008 – 0,021) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-87/Z-04126/02","norm_bases":["PN-87/Z-04126/02"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość związków chromu (VI) - w przeliczeniu na Cr (VI)\nZakres:\nZakres (0,00038 – 0,011) mg/m3\nZakres (0,0008 – 0,021) mg w próbce\nMetoda spektrofotometryczna PN-87/Z-04126/02 Srodowisko pracy − powietrze Stezenie/zawartosc zwiazkow chromu (VI) - w przeliczeniu na Cr (VI)\nZakres:\nZakres (0,00038 – 0,011) mg/m3\nZakres (0,0008 – 0,021) mg w probce\nMetoda spektrofotometryczna PN-87/Z-04126/02","categories":["environment"],"row_index":224,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of chromium (VI) compounds - calculated as Cr (VI)","parameters_en":[{"name":"Range","range":"(0,00038 – 0,011) mg/m3"},{"name":"Range","range":"(0,0008 – 0,021) mg w próbce"}],"search_en":"Workplace environment − air Concentration/content of chromium (VI) compounds - calculated as Cr (VI) Spectrophotometric method Range Range PN-87/Z-04126/02","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"范围","range":"(0,00038 – 0,011) mg/m3"},{"name":"范围","range":"(0,0008 – 0,021) mg w próbce"}],"search_zh":"工作环境 − 空气 分光光度法 范围 范围 PN-87/Z-04126/02","technique_zh":"分光光度法","test_object_zh":"工作环境 − 空气"},{"_id":"6a836fb9af14b9c0e7b1ebf8","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość kwasu octowego","parameters":[{"name":"Zakres","range":"(0,83 – 100,00) mg/m3"},{"name":"Zakres","range":"(0,025 – 1,500) mg w próbce"},{"name":"Zakres","range":"(0,33 – 40,13) ppm"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość kwasu octowego\nZakres:\nZakres (0,83 – 100,00) mg/m3\nZakres (0,025 – 1,500) mg w próbce\nZakres (0,33 – 40,13) ppm\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04323:2004","norm_bases":["PN-Z-04323:2004"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość kwasu octowego\nZakres:\nZakres (0,83 – 100,00) mg/m3\nZakres (0,025 – 1,500) mg w próbce\nZakres (0,33 – 40,13) ppm\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04323:2004 Srodowisko pracy − powietrze Stezenie/zawartosc kwasu octowego\nZakres:\nZakres (0,83 – 100,00) mg/m3\nZakres (0,025 – 1,500) mg w probce\nZakres (0,33 – 40,13) ppm\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04323:2004","categories":["environment"],"row_index":225,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Acetic acid concentration/content","parameters_en":[{"name":"Range","range":"(0,83 – 100,00) mg/m3"},{"name":"Range","range":"(0,025 – 1,500) mg w próbce"},{"name":"Range","range":"(0,33 – 40,13) ppm"}],"search_en":"Workplace environment − air Acetic acid concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range Range PN-Z-04323:2004","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"范围","range":"(0,83 – 100,00) mg/m3"},{"name":"范围","range":"(0,025 – 1,500) mg w próbce"},{"name":"范围","range":"(0,33 – 40,13) ppm"}],"search_zh":"工作环境 − 空气 乙酸的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 范围 PN-Z-04323:2004","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作环境 − 空气","methodology_zh":"乙酸的浓度/含量"},{"_id":"6a836fb9af14b9c0e7b1ebf9","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość chlorowodoru","parameters":[{"name":"Zakres","range":"(0,50 –20,00) mg/m3"},{"name":"Zakres","range":"(0,20 – 8,00) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość chlorowodoru\nZakres:\nZakres (0,50 –20,00) mg/m3\nZakres (0,20 – 8,00) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-Z-04450:2014-08","norm_bases":["PN-Z-04450:2014-08"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość chlorowodoru\nZakres:\nZakres (0,50 –20,00) mg/m3\nZakres (0,20 – 8,00) mg w próbce\nMetoda spektrofotometryczna PN-Z-04450:2014-08 Srodowisko pracy − powietrze Stezenie/zawartosc chlorowodoru\nZakres:\nZakres (0,50 –20,00) mg/m3\nZakres (0,20 – 8,00) mg w probce\nMetoda spektrofotometryczna PN-Z-04450:2014-08","categories":["environment"],"row_index":226,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrogen chloride concentration/content","parameters_en":[{"name":"Range","range":"(0,50 –20,00) mg/m3"},{"name":"Range","range":"(0,20 – 8,00) mg w próbce"}],"search_en":"Workplace environment − air Hydrogen chloride concentration/content Spectrophotometric method Range Range PN-Z-04450:2014-08","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"范围","range":"(0,50 –20,00) mg/m3"},{"name":"范围","range":"(0,20 – 8,00) mg w próbce"}],"search_zh":"工作环境 − 空气 氯化氢的浓度/含量 分光光度法 范围 范围 PN-Z-04450:2014-08","technique_zh":"分光光度法","test_object_zh":"工作环境 − 空气","methodology_zh":"氯化氢的浓度/含量"},{"_id":"6a836fb9af14b9c0e7b1ebfa","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość krystalicznej","parameters":[{"name":"krzemionki (kwarc, krystobalit)"},{"name":"frakcja respirabilna"},{"name":"Zakres","range":"(0,005 – 0,988) mg/m3"},{"name":"Zakres","range":"(0,005 – 0,400) mg w próbce"}],"technique":"Metoda spektrometrii w zakresie podczerwieni z transformacją Fouriera (FT-IR)","techniques":["Metoda spektrometrii w zakresie podczerwieni z transformacją Fouriera (FT-IR)"],"computed":[],"activity":"Stężenie/zawartość krystalicznej\nZakres:\nkrzemionki (kwarc, krystobalit)\nfrakcja respirabilna\nZakres (0,005 – 0,988) mg/m3\nZakres (0,005 – 0,400) mg w próbce\nMetoda spektrometrii w zakresie podczerwieni z transformacją Fouriera (FT-IR)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2012, nr 4(74) s. 117-130","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2012, nr 4(74) s. 117-130"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość krystalicznej\nZakres:\nkrzemionki (kwarc, krystobalit)\nfrakcja respirabilna\nZakres (0,005 – 0,988) mg/m3\nZakres (0,005 – 0,400) mg w próbce\nMetoda spektrometrii w zakresie podczerwieni z transformacją Fouriera (FT-IR) Podstawy i Metody Oceny Środowiska Pracy 2012, nr 4(74) s. 117-130 Srodowisko pracy − powietrze Stezenie/zawartosc krystalicznej\nZakres:\nkrzemionki (kwarc, krystobalit)\nfrakcja respirabilna\nZakres (0,005 – 0,988) mg/m3\nZakres (0,005 – 0,400) mg w probce\nMetoda spektrometrii w zakresie podczerwieni z transformacja Fouriera (FT-IR) Podstawy i Metody Oceny Srodowiska Pracy 2012, nr 4(74) s. 117-130","categories":["environment"],"row_index":227,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Stężenie/zawartość krystalicznej","parameters_en":[{"name":"silica (quartz, cristobalite)"},{"name":"respirable fraction"},{"name":"Range","range":"(0,005 – 0,988) mg/m3"},{"name":"Range","range":"(0,005 – 0,400) mg w próbce"}],"search_en":"Workplace environment − air Stężenie/zawartość krystalicznej Fourier transform infrared spectrometry (FT-IR) silica (quartz, cristobalite) respirable fraction Range Range Podstawy i Metody Oceny Środowiska Pracy 2012, nr 4(74) s. 117-130","technique_en":"Fourier transform infrared spectrometry (FT-IR)","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"krzemionki (kwarc, krystobalit)"},{"name":"呼吸性组分"},{"name":"范围","range":"(0,005 – 0,988) mg/m3"},{"name":"范围","range":"(0,005 – 0,400) mg w próbce"}],"search_zh":"工作环境 − 空气 傅里叶变换红外光谱法（FT-IR） 呼吸性组分 范围 范围 Podstawy i Metody Oceny Środowiska Pracy 2012, nr 4(74) s. 117-130","test_object_zh":"工作环境 − 空气","technique_zh":"傅里叶变换红外光谱法（FT-IR）"},{"_id":"6a836fb9af14b9c0e7b1ebfb","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna","parameters":[{"name":"pyły niesklasyfikowane ze względu na toksyczność"},{"name":"pyły drewna"},{"name":"pyły mąki"},{"name":"asfalt naftowy"},{"name":"Zakres","range":"(0,08 – 40,83) mg/m3"},{"name":"Zakres","range":"(0,06 – 2,45) mg w próbce"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie/zawartość pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna\nZakres:\npyły niesklasyfikowane ze względu na toksyczność\npyły drewna\npyły mąki\nasfalt naftowy\nZakres (0,08 – 40,83) mg/m3\nZakres (0,06 – 2,45) mg w próbce\nMetoda grawimetryczna","reference":"PN-Z-04507:2022-05+Ap1:2022-08","norm_bases":["PN-Z-04507:2022-05+Ap1:2022-08"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna\nZakres:\npyły niesklasyfikowane ze względu na toksyczność\npyły drewna\npyły mąki\nasfalt naftowy\nZakres (0,08 – 40,83) mg/m3\nZakres (0,06 – 2,45) mg w próbce\nMetoda grawimetryczna PN-Z-04507:2022-05+Ap1:2022-08 Srodowisko pracy − powietrze Stezenie/zawartosc pylowych czynnikow szkodliwych dla zdrowia - frakcja wdychalna\nZakres:\npyly niesklasyfikowane ze wzgledu na toksycznosc\npyly drewna\npyly maki\nasfalt naftowy\nZakres (0,08 – 40,83) mg/m3\nZakres (0,06 – 2,45) mg w probce\nMetoda grawimetryczna PN-Z-04507:2022-05+Ap1:2022-08","categories":["environment"],"row_index":228,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of harmful dust agents - inhalable fraction","parameters_en":[{"name":"dusts not classified according to toxicity"},{"name":"wood dusts"},{"name":"flour dusts"},{"name":"petroleum bitumen"},{"name":"Range","range":"(0,08 – 40,83) mg/m3"},{"name":"Range","range":"(0,06 – 2,45) mg w próbce"}],"search_en":"Workplace environment − air Concentration/content of harmful dust agents - inhalable fraction Gravimetric method dusts not classified according to toxicity wood dusts flour dusts petroleum bitumen Range Range PN-Z-04507:2022-05+Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"未按毒性分类的粉尘"},{"name":"木粉尘"},{"name":"面粉粉尘"},{"name":"石油沥青"},{"name":"范围","range":"(0,08 – 40,83) mg/m3"},{"name":"范围","range":"(0,06 – 2,45) mg w próbce"}],"search_zh":"工作环境 − 空气 重量法 未按毒性分类的粉尘 木粉尘 面粉粉尘 石油沥青 范围 范围 PN-Z-04507:2022-05+Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作环境 − 空气"},{"_id":"6a836fb9af14b9c0e7b1ebfc","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość chloroetenu","parameters":[{"name":"Zakres","range":"(0,11 – 11,11) mg/m3"},{"name":"Zakres","range":"(0,0020 – 0,200) mg w próbce"},{"name":"Zakres","range":"(0,04 – 4,28) ppm"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość chloroetenu\nZakres:\nZakres (0,11 – 11,11) mg/m3\nZakres (0,0020 – 0,200) mg w próbce\nZakres (0,04 – 4,28) ppm\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Metoda 159 Wydanie 3 z dnia 14.12.2020","norm_bases":["Metoda 159 Wydanie 3 z dnia 14.12.2020"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość chloroetenu\nZakres:\nZakres (0,11 – 11,11) mg/m3\nZakres (0,0020 – 0,200) mg w próbce\nZakres (0,04 – 4,28) ppm\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Metoda 159 Wydanie 3 z dnia 14.12.2020 Srodowisko pracy − powietrze Stezenie/zawartosc chloroetenu\nZakres:\nZakres (0,11 – 11,11) mg/m3\nZakres (0,0020 – 0,200) mg w probce\nZakres (0,04 – 4,28) ppm\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Metoda 159 Wydanie 3 z dnia 14.12.2020","categories":["environment"],"row_index":229,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of chloroethene","parameters_en":[{"name":"Range","range":"(0,11 – 11,11) mg/m3"},{"name":"Range","range":"(0,0020 – 0,200) mg w próbce"},{"name":"Range","range":"(0,04 – 4,28) ppm"}],"search_en":"Workplace environment − air Concentration/content of chloroethene Gas chromatography with flame ionization detection (GC-FID) Range Range Range Metoda 159 Wydanie 3 z dnia 14.12.2020","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"范围","range":"(0,11 – 11,11) mg/m3"},{"name":"范围","range":"(0,0020 – 0,200) mg w próbce"},{"name":"范围","range":"(0,04 – 4,28) ppm"}],"search_zh":"工作环境 − 空气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 范围 Metoda 159 Wydanie 3 z dnia 14.12.2020","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作环境 − 空气"},{"_id":"6a836fb9af14b9c0e7b1ebfd","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość 1,2-dichloroetanu","parameters":[{"name":"Zakres","range":"(0,53 – 55,56) mg/m3"},{"name":"Zakres","range":"(0,010 – 1,000) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość 1,2-dichloroetanu\nZakres:\nZakres (0,53 – 55,56) mg/m3\nZakres (0,010 – 1,000) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Metoda 159 Wydanie 3 z dnia 14.12.2020","norm_bases":["Metoda 159 Wydanie 3 z dnia 14.12.2020"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość 1,2-dichloroetanu\nZakres:\nZakres (0,53 – 55,56) mg/m3\nZakres (0,010 – 1,000) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Metoda 159 Wydanie 3 z dnia 14.12.2020 Srodowisko pracy − powietrze Stezenie/zawartosc 1,2-dichloroetanu\nZakres:\nZakres (0,53 – 55,56) mg/m3\nZakres (0,010 – 1,000) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Metoda 159 Wydanie 3 z dnia 14.12.2020","categories":["environment"],"row_index":230,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of 1,2-dichloroethane","parameters_en":[{"name":"Range","range":"(0,53 – 55,56) mg/m3"},{"name":"Range","range":"(0,010 – 1,000) mg w próbce"}],"search_en":"Workplace environment − air Concentration/content of 1,2-dichloroethane Gas chromatography with flame ionization detection (GC-FID) Range Range Metoda 159 Wydanie 3 z dnia 14.12.2020","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"范围","range":"(0,53 – 55,56) mg/m3"},{"name":"范围","range":"(0,010 – 1,000) mg w próbce"}],"search_zh":"工作环境 − 空气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 Metoda 159 Wydanie 3 z dnia 14.12.2020","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作环境 − 空气"},{"_id":"6a836fb9af14b9c0e7b1ebfe","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość tetrachloroetenu","parameters":[{"name":"Zakres","range":"(4,0 – 200) mg/m3"},{"name":"Zakres","range":"(0,040 – 2,00) mg w próbce"},{"name":"Zakres","range":"(0,58 – 29,1) ppm"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość tetrachloroetenu\nZakres:\nZakres (4,0 – 200) mg/m3\nZakres (0,040 – 2,00) mg w próbce\nZakres (0,58 – 29,1) ppm\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Metoda 159 Wydanie 3 z dnia 14.12.2020","norm_bases":["Metoda 159 Wydanie 3 z dnia 14.12.2020"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość tetrachloroetenu\nZakres:\nZakres (4,0 – 200) mg/m3\nZakres (0,040 – 2,00) mg w próbce\nZakres (0,58 – 29,1) ppm\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Metoda 159 Wydanie 3 z dnia 14.12.2020 Srodowisko pracy − powietrze Stezenie/zawartosc tetrachloroetenu\nZakres:\nZakres (4,0 – 200) mg/m3\nZakres (0,040 – 2,00) mg w probce\nZakres (0,58 – 29,1) ppm\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Metoda 159 Wydanie 3 z dnia 14.12.2020","categories":["environment"],"row_index":231,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Tetrachloroethene concentration/content","parameters_en":[{"name":"Range","range":"(4,0 – 200) mg/m3"},{"name":"Range","range":"(0,040 – 2,00) mg w próbce"},{"name":"Range","range":"(0,58 – 29,1) ppm"}],"search_en":"Workplace environment − air Tetrachloroethene concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range Range Metoda 159 Wydanie 3 z dnia 14.12.2020","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"范围","range":"(4,0 – 200) mg/m3"},{"name":"范围","range":"(0,040 – 2,00) mg w próbce"},{"name":"范围","range":"(0,58 – 29,1) ppm"}],"search_zh":"工作环境 − 空气 四氯乙烯的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 范围 Metoda 159 Wydanie 3 z dnia 14.12.2020","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作环境 − 空气","methodology_zh":"四氯乙烯的浓度/含量"},{"_id":"6a836fb9af14b9c0e7b1ebff","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość chloroetanu","parameters":[{"name":"Zakres","range":"(6,67 – 2666,7) mg/m3"},{"name":"Zakres","range":"(0,020 – 2,000) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość chloroetanu\nZakres:\nZakres (6,67 – 2666,7) mg/m3\nZakres (0,020 – 2,000) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Metoda 159 Wydanie 3 z dnia 14.12.2020","norm_bases":["Metoda 159 Wydanie 3 z dnia 14.12.2020"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość chloroetanu\nZakres:\nZakres (6,67 – 2666,7) mg/m3\nZakres (0,020 – 2,000) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Metoda 159 Wydanie 3 z dnia 14.12.2020 Srodowisko pracy − powietrze Stezenie/zawartosc chloroetanu\nZakres:\nZakres (6,67 – 2666,7) mg/m3\nZakres (0,020 – 2,000) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Metoda 159 Wydanie 3 z dnia 14.12.2020","categories":["environment"],"row_index":232,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of chloroethane","parameters_en":[{"name":"Range","range":"(6,67 – 2666,7) mg/m3"},{"name":"Range","range":"(0,020 – 2,000) mg w próbce"}],"search_en":"Workplace environment − air Concentration/content of chloroethane Gas chromatography with flame ionization detection (GC-FID) Range Range Metoda 159 Wydanie 3 z dnia 14.12.2020","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"范围","range":"(6,67 – 2666,7) mg/m3"},{"name":"范围","range":"(0,020 – 2,000) mg w próbce"}],"search_zh":"工作环境 − 空气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 Metoda 159 Wydanie 3 z dnia 14.12.2020","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作环境 − 空气"},{"_id":"6a836fb9af14b9c0e7b1ec00","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − oświetlenie elektryczne awaryjne","methodology":"Natężenie oświetlenia","parameters":[{"name":"Zakres","range":"(0,5 – 500) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie oświetlenia\nZakres (0,5 – 500) lx\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 1838:2025-05 z wyłączeniem punktów normy 5.1.3, 5.1.4, 5.2.3, 5.2.4, 5.3.4, 5.3.5, 5.3.7, 6.0","norm_bases":["PN-EN 1838:2025-05 z wyłączeniem punktów normy 5.1.3, 5.1.4, 5.2.3, 5.2.4, 5.3.4, 5.3.5, 5.3.7, 6.0"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − oświetlenie elektryczne awaryjne Natężenie oświetlenia\nZakres (0,5 – 500) lx\nMetoda pomiarowa bezpośrednia PN-EN 1838:2025-05 z wyłączeniem punktów normy 5.1.3, 5.1.4, 5.2.3, 5.2.4, 5.3.4, 5.3.5, 5.3.7, 6.0 Srodowisko pracy − oswietlenie elektryczne awaryjne Natezenie oswietlenia\nZakres (0,5 – 500) lx\nMetoda pomiarowa bezposrednia PN-EN 1838:2025-05 z wylaczeniem punktow normy 5.1.3, 5.1.4, 5.2.3, 5.2.4, 5.3.4, 5.3.5, 5.3.7, 6.0","categories":["environment"],"row_index":233,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance","parameters_en":[{"name":"Range","range":"(0,5 – 500) lx"}],"search_en":"Workplace environment − emergency electric lighting Illuminance Direct measurement method Range PN-EN 1838:2025-05 z wyłączeniem punktów normy 5.1.3, 5.1.4, 5.2.3, 5.2.4, 5.3.4, 5.3.5, 5.3.7, 6.0","technique_en":"Direct measurement method","test_object_en":"Workplace environment − emergency electric lighting","methodology_zh":"照度","parameters_zh":[{"name":"范围","range":"(0,5 – 500) lx"}],"search_zh":"工作环境 － 应急电气照明 照度 直接测量法 范围 PN-EN 1838:2025-05 z wyłączeniem punktów normy 5.1.3, 5.1.4, 5.2.3, 5.2.4, 5.3.4, 5.3.5, 5.3.7, 6.0","technique_zh":"直接测量法","test_object_zh":"工作环境 － 应急电气照明"},{"_id":"6a836fb9af14b9c0e7b1ec01","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − oświetlenie elektryczne awaryjne","methodology":"Stosunek minimalnego do maksymalnego natężenia oświetlenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stosunek minimalnego do maksymalnego natężenia oświetlenia (z obliczeń)","reference":"PN-EN 1838:2025-05 z wyłączeniem punktów normy 5.1.3, 5.1.4, 5.2.3, 5.2.4, 5.3.4, 5.3.5, 5.3.7, 6.0","norm_bases":["PN-EN 1838:2025-05 z wyłączeniem punktów normy 5.1.3, 5.1.4, 5.2.3, 5.2.4, 5.3.4, 5.3.5, 5.3.7, 6.0"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − oświetlenie elektryczne awaryjne Stosunek minimalnego do maksymalnego natężenia oświetlenia (z obliczeń) PN-EN 1838:2025-05 z wyłączeniem punktów normy 5.1.3, 5.1.4, 5.2.3, 5.2.4, 5.3.4, 5.3.5, 5.3.7, 6.0 Srodowisko pracy − oswietlenie elektryczne awaryjne Stosunek minimalnego do maksymalnego natezenia oswietlenia (z obliczen) PN-EN 1838:2025-05 z wylaczeniem punktow normy 5.1.3, 5.1.4, 5.2.3, 5.2.4, 5.3.4, 5.3.5, 5.3.7, 6.0","categories":["environment"],"row_index":234,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ratio of minimum to maximum illuminance (calculated)","search_en":"Workplace environment − emergency electric lighting Ratio of minimum to maximum illuminance (calculated) PN-EN 1838:2025-05 z wyłączeniem punktów normy 5.1.3, 5.1.4, 5.2.3, 5.2.4, 5.3.4, 5.3.5, 5.3.7, 6.0","test_object_en":"Workplace environment − emergency electric lighting","methodology_zh":"最小与最大照度之比（计算值）","search_zh":"工作环境 － 应急电气照明 最小与最大照度之比（计算值） PN-EN 1838:2025-05 z wyłączeniem punktów normy 5.1.3, 5.1.4, 5.2.3, 5.2.4, 5.3.4, 5.3.5, 5.3.7, 6.0","test_object_zh":"工作环境 － 应急电气照明"},{"_id":"6a836fb9af14b9c0e7b1ec02","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − oświetlenie elektryczne awaryjne","methodology":"Równomierność oświetlenia dla strefy wysokiego ryzyka (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równomierność oświetlenia dla strefy wysokiego ryzyka (z obliczeń)","reference":"PN-EN 1838:2025-05 z wyłączeniem punktów normy 5.1.3, 5.1.4, 5.2.3, 5.2.4, 5.3.4, 5.3.5, 5.3.7, 6.0","norm_bases":["PN-EN 1838:2025-05 z wyłączeniem punktów normy 5.1.3, 5.1.4, 5.2.3, 5.2.4, 5.3.4, 5.3.5, 5.3.7, 6.0"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − oświetlenie elektryczne awaryjne Równomierność oświetlenia dla strefy wysokiego ryzyka (z obliczeń) PN-EN 1838:2025-05 z wyłączeniem punktów normy 5.1.3, 5.1.4, 5.2.3, 5.2.4, 5.3.4, 5.3.5, 5.3.7, 6.0 Srodowisko pracy − oswietlenie elektryczne awaryjne Rownomiernosc oswietlenia dla strefy wysokiego ryzyka (z obliczen) PN-EN 1838:2025-05 z wylaczeniem punktow normy 5.1.3, 5.1.4, 5.2.3, 5.2.4, 5.3.4, 5.3.5, 5.3.7, 6.0","categories":["environment"],"row_index":235,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance uniformity for the high-risk zone (calculated)","search_en":"Workplace environment − emergency electric lighting Illuminance uniformity for the high-risk zone (calculated) PN-EN 1838:2025-05 z wyłączeniem punktów normy 5.1.3, 5.1.4, 5.2.3, 5.2.4, 5.3.4, 5.3.5, 5.3.7, 6.0","test_object_en":"Workplace environment − emergency electric lighting","methodology_zh":"高风险区照度均匀度（计算值）","search_zh":"工作环境 － 应急电气照明 高风险区照度均匀度（计算值） PN-EN 1838:2025-05 z wyłączeniem punktów normy 5.1.3, 5.1.4, 5.2.3, 5.2.4, 5.3.4, 5.3.5, 5.3.7, 6.0","test_object_zh":"工作环境 － 应急电气照明"},{"_id":"6a836fb9af14b9c0e7b1ec03","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − oświetlenie elektryczne awaryjne","methodology":"Czas załączania","parameters":[{"name":"Zakres","range":"(1 – 80) s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Czas załączania\nZakres (1 – 80) s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 1838:2025-05 z wyłączeniem punktów normy 5.1.3, 5.1.4, 5.2.3, 5.2.4, 5.3.4, 5.3.5, 5.3.7, 6.0","norm_bases":["PN-EN 1838:2025-05 z wyłączeniem punktów normy 5.1.3, 5.1.4, 5.2.3, 5.2.4, 5.3.4, 5.3.5, 5.3.7, 6.0"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − oświetlenie elektryczne awaryjne Czas załączania\nZakres (1 – 80) s\nMetoda pomiarowa bezpośrednia PN-EN 1838:2025-05 z wyłączeniem punktów normy 5.1.3, 5.1.4, 5.2.3, 5.2.4, 5.3.4, 5.3.5, 5.3.7, 6.0 Srodowisko pracy − oswietlenie elektryczne awaryjne Czas zalaczania\nZakres (1 – 80) s\nMetoda pomiarowa bezposrednia PN-EN 1838:2025-05 z wylaczeniem punktow normy 5.1.3, 5.1.4, 5.2.3, 5.2.4, 5.3.4, 5.3.5, 5.3.7, 6.0","categories":["environment"],"row_index":236,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Closing time","parameters_en":[{"name":"Range","range":"(1 – 80) s"}],"search_en":"Workplace environment − emergency electric lighting Closing time Direct measurement method Range PN-EN 1838:2025-05 z wyłączeniem punktów normy 5.1.3, 5.1.4, 5.2.3, 5.2.4, 5.3.4, 5.3.5, 5.3.7, 6.0","technique_en":"Direct measurement method","test_object_en":"Workplace environment − emergency electric lighting","parameters_zh":[{"name":"范围","range":"(1 – 80) s"}],"search_zh":"工作环境 － 应急电气照明 接通时间 直接测量法 范围 PN-EN 1838:2025-05 z wyłączeniem punktów normy 5.1.3, 5.1.4, 5.2.3, 5.2.4, 5.3.4, 5.3.5, 5.3.7, 6.0","technique_zh":"直接测量法","methodology_zh":"接通时间","test_object_zh":"工作环境 － 应急电气照明"},{"_id":"6a836fb9af14b9c0e7b1ec04","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − oświetlenie elektryczne awaryjne","methodology":"Minimalny czas stosowania oświetlenia","parameters":[{"name":"Zakres","range":"(1 – 3600) s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Minimalny czas stosowania oświetlenia\nZakres (1 – 3600) s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 1838:2025-05 z wyłączeniem punktów normy 5.1.3, 5.1.4, 5.2.3, 5.2.4, 5.3.4, 5.3.5, 5.3.7, 6.0","norm_bases":["PN-EN 1838:2025-05 z wyłączeniem punktów normy 5.1.3, 5.1.4, 5.2.3, 5.2.4, 5.3.4, 5.3.5, 5.3.7, 6.0"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − oświetlenie elektryczne awaryjne Minimalny czas stosowania oświetlenia\nZakres (1 – 3600) s\nMetoda pomiarowa bezpośrednia PN-EN 1838:2025-05 z wyłączeniem punktów normy 5.1.3, 5.1.4, 5.2.3, 5.2.4, 5.3.4, 5.3.5, 5.3.7, 6.0 Srodowisko pracy − oswietlenie elektryczne awaryjne Minimalny czas stosowania oswietlenia\nZakres (1 – 3600) s\nMetoda pomiarowa bezposrednia PN-EN 1838:2025-05 z wylaczeniem punktow normy 5.1.3, 5.1.4, 5.2.3, 5.2.4, 5.3.4, 5.3.5, 5.3.7, 6.0","categories":["environment"],"row_index":237,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Minimum duration of lighting operation","parameters_en":[{"name":"Range","range":"(1 – 3600) s"}],"search_en":"Workplace environment − emergency electric lighting Minimum duration of lighting operation Direct measurement method Range PN-EN 1838:2025-05 z wyłączeniem punktów normy 5.1.3, 5.1.4, 5.2.3, 5.2.4, 5.3.4, 5.3.5, 5.3.7, 6.0","technique_en":"Direct measurement method","test_object_en":"Workplace environment − emergency electric lighting","parameters_zh":[{"name":"范围","range":"(1 – 3600) s"}],"search_zh":"工作环境 － 应急电气照明 照明的最短使用时间 直接测量法 范围 PN-EN 1838:2025-05 z wyłączeniem punktów normy 5.1.3, 5.1.4, 5.2.3, 5.2.4, 5.3.4, 5.3.5, 5.3.7, 6.0","technique_zh":"直接测量法","methodology_zh":"照明的最短使用时间","test_object_zh":"工作环境 － 应急电气照明"},{"_id":"6a836fb9af14b9c0e7b1ec05","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − oświetlenie elektryczne we wnętrzach","methodology":"Natężenie oświetlenia","parameters":[{"name":"Zakres","range":"(5 – 5 000) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie oświetlenia\nZakres (5 – 5 000) lx\nMetoda pomiarowa bezpośrednia","reference":"Metoda 032 wyd. 7 z dnia 19.02.2026","norm_bases":["Metoda 032 wyd. 7 z dnia 19.02.2026"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − oświetlenie elektryczne we wnętrzach Natężenie oświetlenia\nZakres (5 – 5 000) lx\nMetoda pomiarowa bezpośrednia Metoda 032 wyd. 7 z dnia 19.02.2026 Srodowisko pracy − oswietlenie elektryczne we wnetrzach Natezenie oswietlenia\nZakres (5 – 5 000) lx\nMetoda pomiarowa bezposrednia Metoda 032 wyd. 7 z dnia 19.02.2026","categories":["environment"],"row_index":238,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance","parameters_en":[{"name":"Range","range":"(5 – 5 000) lx"}],"search_en":"Workplace environment − indoor electric lighting Illuminance Direct measurement method Range Metoda 032 wyd. 7 z dnia 19.02.2026","technique_en":"Direct measurement method","test_object_en":"Workplace environment − indoor electric lighting","methodology_zh":"照度","parameters_zh":[{"name":"范围","range":"(5 – 5 000) lx"}],"search_zh":"工作场所环境 − 室内电气照明 照度 直接测量法 范围 Metoda 032 wyd. 7 z dnia 19.02.2026","technique_zh":"直接测量法","test_object_zh":"工作场所环境 − 室内电气照明"},{"_id":"6a836fb9af14b9c0e7b1ec06","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − oświetlenie elektryczne we wnętrzach","methodology":"Równomierność oświetlenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równomierność oświetlenia (z obliczeń)","reference":"Metoda 032 wyd. 7 z dnia 19.02.2026","norm_bases":["Metoda 032 wyd. 7 z dnia 19.02.2026"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − oświetlenie elektryczne we wnętrzach Równomierność oświetlenia (z obliczeń) Metoda 032 wyd. 7 z dnia 19.02.2026 Srodowisko pracy − oswietlenie elektryczne we wnetrzach Rownomiernosc oswietlenia (z obliczen) Metoda 032 wyd. 7 z dnia 19.02.2026","categories":["environment"],"row_index":239,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance uniformity (calculated)","search_en":"Workplace environment − indoor electric lighting Illuminance uniformity (calculated) Metoda 032 wyd. 7 z dnia 19.02.2026","test_object_en":"Workplace environment − indoor electric lighting","methodology_zh":"照度均匀度（计算值）","search_zh":"工作场所环境 − 室内电气照明 照度均匀度（计算值） Metoda 032 wyd. 7 z dnia 19.02.2026","test_object_zh":"工作场所环境 − 室内电气照明"},{"_id":"6a836fb9af14b9c0e7b1ec07","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − oświetlenie elektryczne na zewnątrz","methodology":"Natężenie oświetlenia","parameters":[{"name":"Zakres","range":"(5 – 500) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie oświetlenia\nZakres (5 – 500) lx\nMetoda pomiarowa bezpośrednia","reference":"Metoda 032 wyd. 7 z dnia 19.02.2026","norm_bases":["Metoda 032 wyd. 7 z dnia 19.02.2026"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − oświetlenie elektryczne na zewnątrz Natężenie oświetlenia\nZakres (5 – 500) lx\nMetoda pomiarowa bezpośrednia Metoda 032 wyd. 7 z dnia 19.02.2026 Srodowisko pracy − oswietlenie elektryczne na zewnatrz Natezenie oswietlenia\nZakres (5 – 500) lx\nMetoda pomiarowa bezposrednia Metoda 032 wyd. 7 z dnia 19.02.2026","categories":["environment"],"row_index":240,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance","parameters_en":[{"name":"Range","range":"(5 – 500) lx"}],"search_en":"Workplace environment − outdoor electric lighting Illuminance Direct measurement method Range Metoda 032 wyd. 7 z dnia 19.02.2026","technique_en":"Direct measurement method","test_object_en":"Workplace environment − outdoor electric lighting","methodology_zh":"照度","parameters_zh":[{"name":"范围","range":"(5 – 500) lx"}],"search_zh":"工作环境 － 室外电气照明 照度 直接测量法 范围 Metoda 032 wyd. 7 z dnia 19.02.2026","technique_zh":"直接测量法","test_object_zh":"工作环境 － 室外电气照明"},{"_id":"6a836fb9af14b9c0e7b1ec08","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − oświetlenie elektryczne na zewnątrz","methodology":"Równomierność oświetlenia (z obliczeń), Zróżnicowanie natężenia oświetlenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równomierność oświetlenia (z obliczeń), Zróżnicowanie natężenia oświetlenia (z obliczeń)","reference":"Metoda 032 wyd. 7 z dnia 19.02.2026","norm_bases":["Metoda 032 wyd. 7 z dnia 19.02.2026"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − oświetlenie elektryczne na zewnątrz Równomierność oświetlenia (z obliczeń), Zróżnicowanie natężenia oświetlenia (z obliczeń) Metoda 032 wyd. 7 z dnia 19.02.2026 Srodowisko pracy − oswietlenie elektryczne na zewnatrz Rownomiernosc oswietlenia (z obliczen), Zroznicowanie natezenia oswietlenia (z obliczen) Metoda 032 wyd. 7 z dnia 19.02.2026","categories":["environment"],"row_index":241,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Uniformity of lighting (calculated), Variation in illuminance (calculated)","search_en":"Workplace environment − outdoor electric lighting Uniformity of lighting (calculated), Variation in illuminance (calculated) Metoda 032 wyd. 7 z dnia 19.02.2026","test_object_en":"Workplace environment − outdoor electric lighting","search_zh":"工作环境 － 室外电气照明 Metoda 032 wyd. 7 z dnia 19.02.2026","test_object_zh":"工作环境 － 室外电气照明"},{"_id":"6a836fb9af14b9c0e7b1ec09","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − mikroklimat umiarkowany","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(10 – 40) oC"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(10 - 40) oC"},{"name":"Wilgotność powietrza"},{"name":"Zakres","range":"(25 – 75) %"},{"name":"Prędkość powietrza"},{"name":"Zakres","range":"(0,15 – 10) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (10 – 40) oC\nTemperatura poczernionej kuli\nZakres (10 - 40) oC\nWilgotność powietrza\nZakres (25 – 75) %\nPrędkość powietrza\nZakres (0,15 – 10) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7730:2006+Ap1:2014","norm_bases":["PN-EN ISO 7730:2006+Ap1:2014"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − mikroklimat umiarkowany Temperatura powietrza\nZakres:\nZakres (10 – 40) oC\nTemperatura poczernionej kuli\nZakres (10 - 40) oC\nWilgotność powietrza\nZakres (25 – 75) %\nPrędkość powietrza\nZakres (0,15 – 10) m/s\nMetoda pomiarowa bezpośrednia PN-EN ISO 7730:2006+Ap1:2014 Srodowisko pracy − mikroklimat umiarkowany Temperatura powietrza\nZakres:\nZakres (10 – 40) oC\nTemperatura poczernionej kuli\nZakres (10 - 40) oC\nWilgotnosc powietrza\nZakres (25 – 75) %\nPredkosc powietrza\nZakres (0,15 – 10) m/s\nMetoda pomiarowa bezposrednia PN-EN ISO 7730:2006+Ap1:2014","categories":["environment"],"row_index":242,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(10 – 40) oC"},{"name":"Black globe temperature"},{"name":"Range","range":"(10 - 40) oC"},{"name":"Air humidity"},{"name":"Range","range":"(25 – 75) %"},{"name":"Air velocity"},{"name":"Range","range":"(0,15 – 10) m/s"}],"search_en":"Workplace environment − moderate microclimate Air temperature Direct measurement method Range Black globe temperature Range Air humidity Range Air velocity Range PN-EN ISO 7730:2006+Ap1:2014","technique_en":"Direct measurement method","test_object_en":"Workplace environment − moderate microclimate","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(10 – 40) oC"},{"name":"黑球温度"},{"name":"范围","range":"(10 - 40) oC"},{"name":"空气湿度"},{"name":"范围","range":"(25 – 75) %"},{"name":"空气流速"},{"name":"范围","range":"(0,15 – 10) m/s"}],"search_zh":"工作场所环境 − 中等微气候 空气温度 直接测量法 范围 黑球温度 范围 空气湿度 范围 空气流速 范围 PN-EN ISO 7730:2006+Ap1:2014","technique_zh":"直接测量法","test_object_zh":"工作场所环境 − 中等微气候"},{"_id":"6a836fb9af14b9c0e7b1ec0a","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − mikroklimat umiarkowany","methodology":"Wskaźnik PMV, Wskaźnik PPD (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik PMV, Wskaźnik PPD (z obliczeń)","reference":"PN-EN ISO 7730:2006+Ap1:2014","norm_bases":["PN-EN ISO 7730:2006+Ap1:2014"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − mikroklimat umiarkowany Wskaźnik PMV, Wskaźnik PPD (z obliczeń) PN-EN ISO 7730:2006+Ap1:2014 Srodowisko pracy − mikroklimat umiarkowany Wskaznik PMV, Wskaznik PPD (z obliczen) PN-EN ISO 7730:2006+Ap1:2014","categories":["environment"],"row_index":243,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"PMV index, PPD index (calculated)","search_en":"Workplace environment − moderate microclimate PMV index, PPD index (calculated) PN-EN ISO 7730:2006+Ap1:2014","test_object_en":"Workplace environment − moderate microclimate","methodology_zh":"PMV 指数、PPD 指数（计算值）","search_zh":"工作场所环境 − 中等微气候 PMV 指数、PPD 指数（计算值） PN-EN ISO 7730:2006+Ap1:2014","test_object_zh":"工作场所环境 − 中等微气候"},{"_id":"6a836fb9af14b9c0e7b1ec0b","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − mikroklimat gorący","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(20 – 40) oC"},{"name":"Temperatura wilgotna naturalna"},{"name":"Zakres","range":"(20 – 40) oC"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(20 – 40) oC"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (20 – 40) oC\nTemperatura wilgotna naturalna\nZakres (20 – 40) oC\nTemperatura poczernionej kuli\nZakres (20 – 40) oC\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7243:2018-01+Ap2:2020-04","norm_bases":["PN-EN ISO 7243:2018-01+Ap2:2020-04"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − mikroklimat gorący Temperatura powietrza\nZakres:\nZakres (20 – 40) oC\nTemperatura wilgotna naturalna\nZakres (20 – 40) oC\nTemperatura poczernionej kuli\nZakres (20 – 40) oC\nMetoda pomiarowa bezpośrednia PN-EN ISO 7243:2018-01+Ap2:2020-04 Srodowisko pracy − mikroklimat goracy Temperatura powietrza\nZakres:\nZakres (20 – 40) oC\nTemperatura wilgotna naturalna\nZakres (20 – 40) oC\nTemperatura poczernionej kuli\nZakres (20 – 40) oC\nMetoda pomiarowa bezposrednia PN-EN ISO 7243:2018-01+Ap2:2020-04","categories":["environment"],"row_index":244,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(20 – 40) oC"},{"name":"Natural wet bulb temperature"},{"name":"Range","range":"(20 – 40) oC"},{"name":"Black globe temperature"},{"name":"Range","range":"(20 – 40) oC"}],"search_en":"Workplace environment − hot microclimate Air temperature Direct measurement method Range Natural wet bulb temperature Range Black globe temperature Range PN-EN ISO 7243:2018-01+Ap2:2020-04","technique_en":"Direct measurement method","test_object_en":"Workplace environment − hot microclimate","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(20 – 40) oC"},{"name":"自然湿球温度"},{"name":"范围","range":"(20 – 40) oC"},{"name":"黑球温度"},{"name":"范围","range":"(20 – 40) oC"}],"search_zh":"工作场所环境 − 高温微气候 空气温度 直接测量法 范围 自然湿球温度 范围 黑球温度 范围 PN-EN ISO 7243:2018-01+Ap2:2020-04","technique_zh":"直接测量法","test_object_zh":"工作场所环境 − 高温微气候"},{"_id":"6a836fb9af14b9c0e7b1ec0c","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − mikroklimat gorący","methodology":"Wskaźnik WBGT, WBGTeff (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik WBGT, WBGTeff (z obliczeń)","reference":"PN-EN ISO 7243:2018-01+Ap2:2020-04","norm_bases":["PN-EN ISO 7243:2018-01+Ap2:2020-04"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − mikroklimat gorący Wskaźnik WBGT, WBGTeff (z obliczeń) PN-EN ISO 7243:2018-01+Ap2:2020-04 Srodowisko pracy − mikroklimat goracy Wskaznik WBGT, WBGTeff (z obliczen) PN-EN ISO 7243:2018-01+Ap2:2020-04","categories":["environment"],"row_index":245,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"WBGT, WBGTeff index (calculated)","search_en":"Workplace environment − hot microclimate WBGT, WBGTeff index (calculated) PN-EN ISO 7243:2018-01+Ap2:2020-04","test_object_en":"Workplace environment − hot microclimate","search_zh":"工作场所环境 − 高温微气候 WBGT 指数、WBGTeff 指数（由计算得出） PN-EN ISO 7243:2018-01+Ap2:2020-04","test_object_zh":"工作场所环境 − 高温微气候","methodology_zh":"WBGT 指数、WBGTeff 指数（由计算得出）"},{"_id":"6a836fb9af14b9c0e7b1ec0d","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − drgania o ogólnym działaniu na organizm człowieka","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","parameters":[{"name":"Zakres","range":"(0,10 – 50) m/s2"},{"name":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8 godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników","range":"(1.4awx, 1.4awy, awz)"},{"name":"Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników","range":"(1.4awx, 1.4awy, awz)"},{"name":"(z obliczeń)"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres:\nZakres (0,10 – 50) m/s2\nEkspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8 godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz)\nEkspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz)\n(z obliczeń)\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − drgania o ogólnym działaniu na organizm człowieka Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres:\nZakres (0,10 – 50) m/s2\nEkspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8 godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz)\nEkspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz)\n(z obliczeń)\nMetoda pomiarowa bezpośrednia PN-EN 14253+A1:2011 Srodowisko pracy − drgania o ogolnym dzialaniu na organizm czlowieka Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres:\nZakres (0,10 – 50) m/s2\nEkspozycja dzienna, wyrazona w postaci rownowaznego energetycznie dla 8 godzin dzialania skutecznego, skorygowanego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1.4awx, 1.4awy, awz)\nEkspozycja trwajaca 30 minut i krocej, wyrazona w postaci skutecznego, wazonego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1.4awx, 1.4awy, awz)\n(z obliczen)\nMetoda pomiarowa bezposrednia PN-EN 14253+A1:2011","categories":["environment"],"row_index":246,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Frequency-weighted r.m.s. vibration acceleration","parameters_en":[{"name":"Range","range":"(0,10 – 50) m/s2"},{"name":"Daily exposure, expressed as the energy-equivalent for 8 hours of the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for the three directional components, taking into account the relevant factors","range":"(1.4awx, 1.4awy, awz)"},{"name":"Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for the three directional components, taking into account the relevant factors","range":"(1.4awx, 1.4awy, awz)"},{"name":"(calculated)"}],"search_en":"Workplace environment − whole-body vibration Frequency-weighted r.m.s. vibration acceleration Direct measurement method Range Daily exposure, expressed as the energy-equivalent for 8 hours of the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for the three directional components, taking into account the relevant factors Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for the three directional components, taking into account the relevant factors (calculated) PN-EN 14253+A1:2011","technique_en":"Direct measurement method","test_object_en":"Workplace environment − whole-body vibration","methodology_zh":"频率计权振动加速度有效值","parameters_zh":[{"name":"范围","range":"(0,10 – 50) m/s2"},{"name":"日暴露量，以三个方向分量所测定的振动加速度中占主导的频率计权有效振动加速度的8小时能量等效值表示","range":"(1.4awx, 1.4awy, awz)"},{"name":"持续30分钟及以下的暴露量，以考虑相应系数后三个方向分量所测定的振动加速度中占主导的频率计权有效振动加速度表示","range":"(1.4awx, 1.4awy, awz)"},{"name":"（计算得出）"}],"search_zh":"工作场所环境 − 全身振动 频率计权振动加速度有效值 直接测量法 范围 日暴露量，以三个方向分量所测定的振动加速度中占主导的频率计权有效振动加速度的8小时能量等效值表示 持续30分钟及以下的暴露量，以考虑相应系数后三个方向分量所测定的振动加速度中占主导的频率计权有效振动加速度表示 （计算得出） PN-EN 14253+A1:2011","technique_zh":"直接测量法","test_object_zh":"工作场所环境 − 全身振动"},{"_id":"6a836fb9af14b9c0e7b1ec0e","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy - drgania działające na organizm człowieka przez kończyny górne","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","parameters":[{"name":"Zakres","range":"(0,20 – 100) m/s2"},{"name":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8 godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres:\nZakres (0,20 – 100) m/s2\nEkspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8 godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-2:2004/A1:2015-11"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - drgania działające na organizm człowieka przez kończyny górne Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres:\nZakres (0,20 – 100) m/s2\nEkspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8 godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)\nMetoda pomiarowa bezpośrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 Srodowisko pracy - drgania dzialajace na organizm czlowieka przez konczyny gorne Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres:\nZakres (0,20 – 100) m/s2\nEkspozycja dzienna, wyrazona w postaci rownowaznej energetycznie dla 8 godzin dzialania sumy wektorowej skutecznych, skorygowanych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz) Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci sumy wektorowej skutecznych, wazonych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz) (z obliczen)\nMetoda pomiarowa bezposrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","categories":["environment"],"row_index":247,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Frequency-weighted r.m.s. vibration acceleration","parameters_en":[{"name":"Range","range":"(0,20 – 100) m/s2"},{"name":"Daily exposure, expressed as the energy equivalent for 8 hours of action of the vector sum of r.m.s. frequency-corrected vibration accelerations, determined for three directional components (ahwx, ahwy, ahwz) Exposure lasting 30 minutes and less, expressed as the vector sum of r.m.s. frequency-weighted vibration accelerations determined for the three directional components (ahwx, ahwy, ahwz) (calculated)"}],"search_en":"Workplace environment - hand-arm vibration Frequency-weighted r.m.s. vibration acceleration Direct measurement method Range Daily exposure, expressed as the energy equivalent for 8 hours of action of the vector sum of r.m.s. frequency-corrected vibration accelerations, determined for three directional components (ahwx, ahwy, ahwz) Exposure lasting 30 minutes and less, expressed as the vector sum of r.m.s. frequency-weighted vibration accelerations determined for the three directional components (ahwx, ahwy, ahwz) (calculated) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","technique_en":"Direct measurement method","test_object_en":"Workplace environment - hand-arm vibration","methodology_zh":"频率计权振动加速度有效值","parameters_zh":[{"name":"范围","range":"(0,20 – 100) m/s2"},{"name":"日暴露量，以三个方向分量所测定的频率计权有效振动加速度矢量和的8小时能量等效值表示"}],"search_zh":"工作场所环境 — 手传振动 频率计权振动加速度有效值 直接测量法 范围 日暴露量，以三个方向分量所测定的频率计权有效振动加速度矢量和的8小时能量等效值表示 PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 手传振动"},{"_id":"6a836fb9af14b9c0e7b1ec0f","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − hałas","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(34 – 139) dB"},{"name":"Szczytowy poziom dźwięku C"},{"name":"Zakres","range":"(34 – 139) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (34 – 139) dB\nSzczytowy poziom dźwięku C\nZakres (34 – 139) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (34 – 139) dB\nSzczytowy poziom dźwięku C\nZakres (34 – 139) dB\nMetoda pomiarowa bezpośrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11 Srodowisko pracy − halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A\nZakres:\nZakres (34 – 139) dB\nSzczytowy poziom dzwieku C\nZakres (34 – 139) dB\nMetoda pomiarowa bezposrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie 2 i 3 – punkt 10 i 11","categories":["environment"],"row_index":248,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound level Maximum A-weighted sound level","parameters_en":[{"name":"Range","range":"(34 – 139) dB"},{"name":"C-weighted peak sound pressure level"},{"name":"Range","range":"(34 – 139) dB"}],"search_en":"Workplace environment − noise A-weighted equivalent sound level Maximum A-weighted sound level Direct measurement method Range C-weighted peak sound pressure level Range PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11","technique_en":"Direct measurement method","test_object_en":"Workplace environment − noise","methodology_zh":"A 计权等效声级 A 计权最大声级","parameters_zh":[{"name":"范围","range":"(34 – 139) dB"},{"name":"C 计权峰值声级"},{"name":"范围","range":"(34 – 139) dB"}],"search_zh":"工作环境 − 噪声 A 计权等效声级 A 计权最大声级 直接测量法 范围 C 计权峰值声级 范围 PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11","technique_zh":"直接测量法","test_object_zh":"工作环境 − 噪声"},{"_id":"6a836fb9af14b9c0e7b1ec10","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − hałas","methodology":"Poziom ekspozycji na hałas odniesiony do:","parameters":[{"name":"8-godz. dobowego wymiaru czasu pracy"},{"name":"przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − hałas Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11 Srodowisko pracy − halas Poziom ekspozycji na halas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzecietnego tygodniowego wymiaru czasu pracy (z obliczen) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie 2 i 3 – punkt 10 i 11","categories":["environment"],"row_index":249,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Noise exposure level referred to:","parameters_en":[{"name":"an 8-hour daily working time"},{"name":"the average weekly working time (calculated)"}],"search_en":"Workplace environment − noise Noise exposure level referred to: an 8-hour daily working time the average weekly working time (calculated) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11","test_object_en":"Workplace environment − noise","methodology_zh":"噪声暴露级，参照：","parameters_zh":[{"name":"8 小时日工作时间"},{"name":"平均每周工作时间（计算值）"}],"search_zh":"工作环境 − 噪声 噪声暴露级，参照： 8 小时日工作时间 平均每周工作时间（计算值） PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11","test_object_zh":"工作环境 − 噪声"},{"_id":"6a836fb9af14b9c0e7b1ec11","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy podczas użytkowania systemów elektroenergetycznych i elektrycznych instalacji zasilających prądu przemiennego w energetyce","methodology":"Natężenie pola elektrycznego:","parameters":[{"name":"w zakresie częstotliwości 50 Hz"},{"name":"Zakres","range":"(0,1 – 20) kV/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości 50 Hz\nZakres (0,1 – 20) kV/m\nMetoda pomiarowa bezpośrednia","reference":"Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4(90), s. 91 - 150","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4(90), s. 91 - 150"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (tekst jednolity Dz. U. z 2018 poz. 331).","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy podczas użytkowania systemów elektroenergetycznych i elektrycznych instalacji zasilających prądu przemiennego w energetyce Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości 50 Hz\nZakres (0,1 – 20) kV/m\nMetoda pomiarowa bezpośrednia Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4(90), s. 91 - 150 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy podczas uzytkowania systemow elektroenergetycznych i elektrycznych instalacji zasilajacych pradu przemiennego w energetyce Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci 50 Hz\nZakres (0,1 – 20) kV/m\nMetoda pomiarowa bezposrednia Podstawy i Metody Oceny Srodowiska Pracy 2016, nr 4(90), s. 91 - 150","categories":["environment"],"row_index":250,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electric field strength:","parameters_en":[{"name":"in the frequency range 50 Hz"},{"name":"Range","range":"(0,1 – 20) kV/m"}],"search_en":"Workplace environment - electromagnetic field in the workspace during the use of power systems and AC electrical supply installations in the power industry Electric field strength: Direct measurement method in the frequency range 50 Hz Range Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4(90), s. 91 - 150","technique_en":"Direct measurement method","test_object_en":"Workplace environment - electromagnetic field in the workspace during the use of power systems and AC electrical supply installations in the power industry","methodology_zh":"电场强度：","parameters_zh":[{"name":"频率范围 50 Hz"},{"name":"范围","range":"(0,1 – 20) kV/m"}],"search_zh":"工作场所环境 — 使用电力系统与电力行业交流供电装置期间工作空间内的电磁场 电场强度： 直接测量法 频率范围 50 Hz 范围 Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4(90), s. 91 - 150","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 使用电力系统与电力行业交流供电装置期间工作空间内的电磁场"},{"_id":"6a836fb9af14b9c0e7b1ec12","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy podczas użytkowania systemów elektroenergetycznych i elektrycznych instalacji zasilających prądu przemiennego w energetyce","methodology":"Indukcja magnetyczna:","parameters":[{"name":"w zakresie częstotliwości 50 Hz"},{"name":"Zakres","range":"1 μT – 10 mT"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Indukcja magnetyczna:\nZakres:\nw zakresie częstotliwości 50 Hz\nZakres 1 μT – 10 mT\nMetoda pomiarowa bezpośrednia","reference":"Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4(90), s. 91 - 150","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4(90), s. 91 - 150"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (tekst jednolity Dz. U. z 2018 poz. 331).","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy podczas użytkowania systemów elektroenergetycznych i elektrycznych instalacji zasilających prądu przemiennego w energetyce Indukcja magnetyczna:\nZakres:\nw zakresie częstotliwości 50 Hz\nZakres 1 μT – 10 mT\nMetoda pomiarowa bezpośrednia Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4(90), s. 91 - 150 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy podczas uzytkowania systemow elektroenergetycznych i elektrycznych instalacji zasilajacych pradu przemiennego w energetyce Indukcja magnetyczna:\nZakres:\nw zakresie czestotliwosci 50 Hz\nZakres 1 μT – 10 mT\nMetoda pomiarowa bezposrednia Podstawy i Metody Oceny Srodowiska Pracy 2016, nr 4(90), s. 91 - 150","categories":["environment"],"row_index":251,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic flux density:","parameters_en":[{"name":"in the frequency range 50 Hz"},{"name":"Range","range":"1 μT – 10 mT"}],"search_en":"Workplace environment - electromagnetic field in the workspace during the use of power systems and AC electrical supply installations in the power industry Magnetic flux density: Direct measurement method in the frequency range 50 Hz Range Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4(90), s. 91 - 150","technique_en":"Direct measurement method","test_object_en":"Workplace environment - electromagnetic field in the workspace during the use of power systems and AC electrical supply installations in the power industry","parameters_zh":[{"name":"频率范围 50 Hz"},{"name":"范围","range":"1 μT – 10 mT"}],"search_zh":"工作场所环境 — 使用电力系统与电力行业交流供电装置期间工作空间内的电磁场 磁感应强度： 直接测量法 频率范围 50 Hz 范围 Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4(90), s. 91 - 150","technique_zh":"直接测量法","methodology_zh":"磁感应强度：","test_object_zh":"工作场所环境 — 使用电力系统与电力行业交流供电装置期间工作空间内的电磁场"},{"_id":"6a836fb9af14b9c0e7b1ec13","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy podczas użytkowania systemów elektroenergetycznych i elektrycznych instalacji zasilających prądu przemiennego w energetyce","methodology":"Natężenie pole magnetycznego o częstotliwości 50 Hz (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pole magnetycznego o częstotliwości 50 Hz (z obliczeń)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4(90), s. 91 - 150","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4(90), s. 91 - 150"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (tekst jednolity Dz. U. z 2018 poz. 331).","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy podczas użytkowania systemów elektroenergetycznych i elektrycznych instalacji zasilających prądu przemiennego w energetyce Natężenie pole magnetycznego o częstotliwości 50 Hz (z obliczeń) Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4(90), s. 91 - 150 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy podczas uzytkowania systemow elektroenergetycznych i elektrycznych instalacji zasilajacych pradu przemiennego w energetyce Natezenie pole magnetycznego o czestotliwosci 50 Hz (z obliczen) Podstawy i Metody Oceny Srodowiska Pracy 2016, nr 4(90), s. 91 - 150","categories":["environment"],"row_index":252,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength at a frequency of 50 Hz (calculated)","search_en":"Workplace environment - electromagnetic field in the workspace during the use of power systems and AC electrical supply installations in the power industry Magnetic field strength at a frequency of 50 Hz (calculated) Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4(90), s. 91 - 150","test_object_en":"Workplace environment - electromagnetic field in the workspace during the use of power systems and AC electrical supply installations in the power industry","search_zh":"工作场所环境 — 使用电力系统与电力行业交流供电装置期间工作空间内的电磁场 Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4(90), s. 91 - 150","test_object_zh":"工作场所环境 — 使用电力系统与电力行业交流供电装置期间工作空间内的电磁场"},{"_id":"6a836fb9af14b9c0e7b1ec14","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość związków niklu w przeliczeniu na Ni – frakcja wdychalna","parameters":[{"name":"Zakres","range":"(0,0009 – 0,16) mg/m3"},{"name":"Zakres","range":"(0,001 – 0,12) mg w próbce"},{"name":"– frakcja respirabilna"},{"name":"Zakres","range":"(0,0006 – 0,11) mg/m3"},{"name":"Zakres","range":"(0,001 – 0,12) mg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie/zawartość związków niklu w przeliczeniu na Ni – frakcja wdychalna\nZakres:\nZakres (0,0009 – 0,16) mg/m3\nZakres (0,001 – 0,12) mg w próbce\n– frakcja respirabilna\nZakres (0,0006 – 0,11) mg/m3\nZakres (0,001 – 0,12) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2021, nr4(110), s. 179-189","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2021, nr4(110), s. 179-189"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość związków niklu w przeliczeniu na Ni – frakcja wdychalna\nZakres:\nZakres (0,0009 – 0,16) mg/m3\nZakres (0,001 – 0,12) mg w próbce\n– frakcja respirabilna\nZakres (0,0006 – 0,11) mg/m3\nZakres (0,001 – 0,12) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) Podstawy i Metody Oceny Środowiska Pracy 2021, nr4(110), s. 179-189 Srodowisko pracy − powietrze Stezenie/zawartosc zwiazkow niklu w przeliczeniu na Ni – frakcja wdychalna\nZakres:\nZakres (0,0009 – 0,16) mg/m3\nZakres (0,001 – 0,12) mg w probce\n– frakcja respirabilna\nZakres (0,0006 – 0,11) mg/m3\nZakres (0,001 – 0,12) mg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) Podstawy i Metody Oceny Srodowiska Pracy 2021, nr4(110), s. 179-189","categories":["environment"],"row_index":253,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of nickel compounds calculated as Ni – inhalable fraction","parameters_en":[{"name":"Range","range":"(0,0009 – 0,16) mg/m3"},{"name":"Range","range":"(0,001 – 0,12) mg w próbce"},{"name":"– respirable fraction"},{"name":"Range","range":"(0,0006 – 0,11) mg/m3"},{"name":"Range","range":"(0,001 – 0,12) mg w próbce"}],"search_en":"Workplace environment − air Concentration/content of nickel compounds calculated as Ni – inhalable fraction Flame atomic absorption spectrometry (FAAS) Range Range – respirable fraction Range Range Podstawy i Metody Oceny Środowiska Pracy 2021, nr4(110), s. 179-189","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"范围","range":"(0,0009 – 0,16) mg/m3"},{"name":"范围","range":"(0,001 – 0,12) mg w próbce"},{"name":"— 呼吸性组分"},{"name":"范围","range":"(0,0006 – 0,11) mg/m3"},{"name":"范围","range":"(0,001 – 0,12) mg w próbce"}],"search_zh":"工作环境 − 空气 火焰原子吸收光谱法（FAAS） 范围 范围 — 呼吸性组分 范围 范围 Podstawy i Metody Oceny Środowiska Pracy 2021, nr4(110), s. 179-189","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作环境 − 空气"},{"_id":"6a836fb9af14b9c0e7b1ec15","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość niklu metalicznego","parameters":[{"name":"Zakres","range":"(0,014 – 0,55) mg/m3"},{"name":"Zakres","range":"(0,010 – 0,400) mg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie/zawartość niklu metalicznego\nZakres:\nZakres (0,014 – 0,55) mg/m3\nZakres (0,010 – 0,400) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04502:2019-10","norm_bases":["PN-Z-04502:2019-10"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość niklu metalicznego\nZakres:\nZakres (0,014 – 0,55) mg/m3\nZakres (0,010 – 0,400) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04502:2019-10 Srodowisko pracy − powietrze Stezenie/zawartosc niklu metalicznego\nZakres:\nZakres (0,014 – 0,55) mg/m3\nZakres (0,010 – 0,400) mg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04502:2019-10","categories":["materials","environment"],"row_index":254,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Metallic nickel concentration/content","parameters_en":[{"name":"Range","range":"(0,014 – 0,55) mg/m3"},{"name":"Range","range":"(0,010 – 0,400) mg w próbce"}],"search_en":"Workplace environment − air Metallic nickel concentration/content Flame atomic absorption spectrometry (FAAS) Range Range PN-Z-04502:2019-10","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"范围","range":"(0,014 – 0,55) mg/m3"},{"name":"范围","range":"(0,010 – 0,400) mg w próbce"}],"search_zh":"工作环境 − 空气 金属镍的浓度/含量 火焰原子吸收光谱法（FAAS） 范围 范围 PN-Z-04502:2019-10","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作环境 − 空气","methodology_zh":"金属镍的浓度/含量"},{"_id":"6a836fb9af14b9c0e7b1ec16","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość ołowiu i jego związków nieorganicznych, z wyjątkiem arsenianu (V) ołowiu (II) oraz chromianu (VI) ołowiu (II) w przeliczeniu na Pb","parameters":[{"name":"frakcja wdychalna"},{"name":"Zakres","range":"(0,0035 – 0,185) mg/m3"},{"name":"Zakres","range":"(0,0025 – 0,100) mg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie/zawartość ołowiu i jego związków nieorganicznych, z wyjątkiem arsenianu (V) ołowiu (II) oraz chromianu (VI) ołowiu (II) w przeliczeniu na Pb\nZakres:\nfrakcja wdychalna\nZakres (0,0035 – 0,185) mg/m3\nZakres (0,0025 – 0,100) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04487:2017-10","norm_bases":["PN-Z-04487:2017-10"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość ołowiu i jego związków nieorganicznych, z wyjątkiem arsenianu (V) ołowiu (II) oraz chromianu (VI) ołowiu (II) w przeliczeniu na Pb\nZakres:\nfrakcja wdychalna\nZakres (0,0035 – 0,185) mg/m3\nZakres (0,0025 – 0,100) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04487:2017-10 Srodowisko pracy − powietrze Stezenie/zawartosc olowiu i jego zwiazkow nieorganicznych, z wyjatkiem arsenianu (V) olowiu (II) oraz chromianu (VI) olowiu (II) w przeliczeniu na Pb\nZakres:\nfrakcja wdychalna\nZakres (0,0035 – 0,185) mg/m3\nZakres (0,0025 – 0,100) mg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04487:2017-10","categories":["environment"],"row_index":255,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of lead and its inorganic compounds, excluding lead (II) arsenate (V) and lead (II) chromate (VI) calculated as Pb","parameters_en":[{"name":"inhalable fraction"},{"name":"Range","range":"(0,0035 – 0,185) mg/m3"},{"name":"Range","range":"(0,0025 – 0,100) mg w próbce"}],"search_en":"Workplace environment − air Concentration/content of lead and its inorganic compounds, excluding lead (II) arsenate (V) and lead (II) chromate (VI) calculated as Pb Flame atomic absorption spectrometry (FAAS) inhalable fraction Range Range PN-Z-04487:2017-10","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"可吸入组分"},{"name":"范围","range":"(0,0035 – 0,185) mg/m3"},{"name":"范围","range":"(0,0025 – 0,100) mg w próbce"}],"search_zh":"工作环境 − 空气 火焰原子吸收光谱法（FAAS） 可吸入组分 范围 范围 PN-Z-04487:2017-10","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作环境 − 空气"},{"_id":"6a836fb9af14b9c0e7b1ec17","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość manganu i jego związków nieorganicznych w przeliczeniu na Mn","parameters":[{"name":"frakcja wdychalna"},{"name":"Zakres","range":"(0,008 – 0,444) mg/m3"},{"name":"Zakres","range":"(0,006 – 0,320) mg w próbce"},{"name":"frakcja respirabilna"},{"name":"Zakres","range":"(0,001 – 0,148) mg/m3"},{"name":"Zakres","range":"(0,0015 – 0,1600) mg w próbce"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie/zawartość manganu i jego związków nieorganicznych w przeliczeniu na Mn\nZakres:\nfrakcja wdychalna\nZakres (0,008 – 0,444) mg/m3\nZakres (0,006 – 0,320) mg w próbce\nfrakcja respirabilna\nZakres (0,001 – 0,148) mg/m3\nZakres (0,0015 – 0,1600) mg w próbce\nMetoda absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04472:2015-10+Ap:1:2015-12","norm_bases":["PN-Z-04472:2015-10+Ap:1:2015-12"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość manganu i jego związków nieorganicznych w przeliczeniu na Mn\nZakres:\nfrakcja wdychalna\nZakres (0,008 – 0,444) mg/m3\nZakres (0,006 – 0,320) mg w próbce\nfrakcja respirabilna\nZakres (0,001 – 0,148) mg/m3\nZakres (0,0015 – 0,1600) mg w próbce\nMetoda absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04472:2015-10+Ap:1:2015-12 Srodowisko pracy − powietrze Stezenie/zawartosc manganu i jego zwiazkow nieorganicznych w przeliczeniu na Mn\nZakres:\nfrakcja wdychalna\nZakres (0,008 – 0,444) mg/m3\nZakres (0,006 – 0,320) mg w probce\nfrakcja respirabilna\nZakres (0,001 – 0,148) mg/m3\nZakres (0,0015 – 0,1600) mg w probce\nMetoda absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04472:2015-10+Ap:1:2015-12","categories":["environment"],"row_index":256,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of manganese and its inorganic compounds expressed as Mn","parameters_en":[{"name":"inhalable fraction"},{"name":"Range","range":"(0,008 – 0,444) mg/m3"},{"name":"Range","range":"(0,006 – 0,320) mg w próbce"},{"name":"respirable fraction"},{"name":"Range","range":"(0,001 – 0,148) mg/m3"},{"name":"Range","range":"(0,0015 – 0,1600) mg w próbce"}],"search_en":"Workplace environment − air Concentration/content of manganese and its inorganic compounds expressed as Mn Atomic absorption spectrometry (FAAS) inhalable fraction Range Range respirable fraction Range Range PN-Z-04472:2015-10+Ap:1:2015-12","technique_en":"Atomic absorption spectrometry (FAAS)","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"可吸入组分"},{"name":"范围","range":"(0,008 – 0,444) mg/m3"},{"name":"范围","range":"(0,006 – 0,320) mg w próbce"},{"name":"呼吸性组分"},{"name":"范围","range":"(0,001 – 0,148) mg/m3"},{"name":"范围","range":"(0,0015 – 0,1600) mg w próbce"}],"search_zh":"工作环境 − 空气 锰及其无机化合物的浓度/含量（以 Mn 计） 原子吸收光谱法（FAAS） 可吸入组分 范围 范围 呼吸性组分 范围 范围 PN-Z-04472:2015-10+Ap:1:2015-12","test_object_zh":"工作环境 − 空气","methodology_zh":"锰及其无机化合物的浓度/含量（以 Mn 计）","technique_zh":"原子吸收光谱法（FAAS）"},{"_id":"6a836fb9af14b9c0e7b1ec18","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość chromu metalicznego, związków chromu: chrom (II), chrom (III), chrom (VI) – w przeliczeniu na Cr","parameters":[{"name":"Zakres","range":"(0,017 – 1,389) mg/m3"},{"name":"Zakres","range":"(0,012 – 1,000) mg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie/zawartość chromu metalicznego, związków chromu: chrom (II), chrom (III), chrom (VI) – w przeliczeniu na Cr\nZakres:\nZakres (0,017 – 1,389) mg/m3\nZakres (0,012 – 1,000) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04434:2011","norm_bases":["PN-Z-04434:2011"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość chromu metalicznego, związków chromu: chrom (II), chrom (III), chrom (VI) – w przeliczeniu na Cr\nZakres:\nZakres (0,017 – 1,389) mg/m3\nZakres (0,012 – 1,000) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04434:2011 Srodowisko pracy − powietrze Stezenie/zawartosc chromu metalicznego, zwiazkow chromu: chrom (II), chrom (III), chrom (VI) – w przeliczeniu na Cr\nZakres:\nZakres (0,017 – 1,389) mg/m3\nZakres (0,012 – 1,000) mg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04434:2011","categories":["materials","environment"],"row_index":257,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of metallic chromium, chromium compounds: chromium (II), chromium (III), chromium (VI) – calculated as Cr","parameters_en":[{"name":"Range","range":"(0,017 – 1,389) mg/m3"},{"name":"Range","range":"(0,012 – 1,000) mg w próbce"}],"search_en":"Workplace environment − air Concentration/content of metallic chromium, chromium compounds: chromium (II), chromium (III), chromium (VI) – calculated as Cr Flame atomic absorption spectrometry (FAAS) Range Range PN-Z-04434:2011","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"范围","range":"(0,017 – 1,389) mg/m3"},{"name":"范围","range":"(0,012 – 1,000) mg w próbce"}],"search_zh":"工作环境 − 空气 火焰原子吸收光谱法（FAAS） 范围 范围 PN-Z-04434:2011","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作环境 − 空气"},{"_id":"6a836fb9af14b9c0e7b1ec19","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość tlenków żelaza w przeliczeniu na Fe tlenek żelaza (III) tlenek żelaza (II) tetratlenek triżelaza","parameters":[{"name":"frakcja respirabilna"},{"name":"Zakres","range":"(0,23 – 6,94) mg/m3"},{"name":"Zakres","range":"(0,125 – 3,750) mg w próbce"},{"name":"frakcja wdychalna"},{"name":"Zakres","range":"(0,35 – 10,42) mg/m3"},{"name":"Zakres","range":"(0,25 – 7,50) mg w próbce"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie/zawartość tlenków żelaza w przeliczeniu na Fe tlenek żelaza (III) tlenek żelaza (II) tetratlenek triżelaza\nZakres:\nfrakcja respirabilna\nZakres (0,23 – 6,94) mg/m3\nZakres (0,125 – 3,750) mg w próbce\nfrakcja wdychalna\nZakres (0,35 – 10,42) mg/m3\nZakres (0,25 – 7,50) mg w próbce\nMetoda absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04469:2025-02","norm_bases":["PN-Z-04469:2025-02"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość tlenków żelaza w przeliczeniu na Fe tlenek żelaza (III) tlenek żelaza (II) tetratlenek triżelaza\nZakres:\nfrakcja respirabilna\nZakres (0,23 – 6,94) mg/m3\nZakres (0,125 – 3,750) mg w próbce\nfrakcja wdychalna\nZakres (0,35 – 10,42) mg/m3\nZakres (0,25 – 7,50) mg w próbce\nMetoda absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04469:2025-02 Srodowisko pracy − powietrze Stezenie/zawartosc tlenkow zelaza w przeliczeniu na Fe tlenek zelaza (III) tlenek zelaza (II) tetratlenek trizelaza\nZakres:\nfrakcja respirabilna\nZakres (0,23 – 6,94) mg/m3\nZakres (0,125 – 3,750) mg w probce\nfrakcja wdychalna\nZakres (0,35 – 10,42) mg/m3\nZakres (0,25 – 7,50) mg w probce\nMetoda absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04469:2025-02","categories":["environment"],"row_index":258,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of iron oxides calculated as Fe iron(III) oxide iron(II) oxide triiron tetraoxide","parameters_en":[{"name":"respirable fraction"},{"name":"Range","range":"(0,23 – 6,94) mg/m3"},{"name":"Range","range":"(0,125 – 3,750) mg w próbce"},{"name":"inhalable fraction"},{"name":"Range","range":"(0,35 – 10,42) mg/m3"},{"name":"Range","range":"(0,25 – 7,50) mg w próbce"}],"search_en":"Workplace environment − air Concentration/content of iron oxides calculated as Fe iron(III) oxide iron(II) oxide triiron tetraoxide Atomic absorption spectrometry (FAAS) respirable fraction Range Range inhalable fraction Range Range PN-Z-04469:2025-02","technique_en":"Atomic absorption spectrometry (FAAS)","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"呼吸性组分"},{"name":"范围","range":"(0,23 – 6,94) mg/m3"},{"name":"范围","range":"(0,125 – 3,750) mg w próbce"},{"name":"可吸入组分"},{"name":"范围","range":"(0,35 – 10,42) mg/m3"},{"name":"范围","range":"(0,25 – 7,50) mg w próbce"}],"search_zh":"工作环境 − 空气 原子吸收光谱法（FAAS） 呼吸性组分 范围 范围 可吸入组分 范围 范围 PN-Z-04469:2025-02","test_object_zh":"工作环境 − 空气","technique_zh":"原子吸收光谱法（FAAS）"},{"_id":"6a836fb9af14b9c0e7b1ec1a","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość wodorotlenku potasu","parameters":[{"name":"Zakres","range":"(0,02 –2,00) mg/m3"},{"name":"Zakres","range":"(0,014 –1,435) mg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie/zawartość wodorotlenku potasu\nZakres:\nZakres (0,02 –2,00) mg/m3\nZakres (0,014 –1,435) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04436:2011","norm_bases":["PN-Z-04436:2011"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość wodorotlenku potasu\nZakres:\nZakres (0,02 –2,00) mg/m3\nZakres (0,014 –1,435) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04436:2011 Srodowisko pracy − powietrze Stezenie/zawartosc wodorotlenku potasu\nZakres:\nZakres (0,02 –2,00) mg/m3\nZakres (0,014 –1,435) mg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04436:2011","categories":["environment"],"row_index":259,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Potassium hydroxide concentration/content","parameters_en":[{"name":"Range","range":"(0,02 –2,00) mg/m3"},{"name":"Range","range":"(0,014 –1,435) mg w próbce"}],"search_en":"Workplace environment − air Potassium hydroxide concentration/content Flame atomic absorption spectrometry (FAAS) Range Range PN-Z-04436:2011","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"范围","range":"(0,02 –2,00) mg/m3"},{"name":"范围","range":"(0,014 –1,435) mg w próbce"}],"search_zh":"工作环境 − 空气 氢氧化钾的浓度/含量 火焰原子吸收光谱法（FAAS） 范围 范围 PN-Z-04436:2011","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作环境 − 空气","methodology_zh":"氢氧化钾的浓度/含量"},{"_id":"6a836fb9af14b9c0e7b1ec1b","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość wodorotlenku sodu","parameters":[{"name":"Zakres","range":"(0,012 – 2,420) mg/m3"},{"name":"Zakres","range":"(0,0087 – 1,7400) mg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie/zawartość wodorotlenku sodu\nZakres:\nZakres (0,012 – 2,420) mg/m3\nZakres (0,0087 – 1,7400) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04435:2011","norm_bases":["PN-Z-04435:2011"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość wodorotlenku sodu\nZakres:\nZakres (0,012 – 2,420) mg/m3\nZakres (0,0087 – 1,7400) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04435:2011 Srodowisko pracy − powietrze Stezenie/zawartosc wodorotlenku sodu\nZakres:\nZakres (0,012 – 2,420) mg/m3\nZakres (0,0087 – 1,7400) mg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04435:2011","categories":["environment"],"row_index":260,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sodium hydroxide concentration/content","parameters_en":[{"name":"Range","range":"(0,012 – 2,420) mg/m3"},{"name":"Range","range":"(0,0087 – 1,7400) mg w próbce"}],"search_en":"Workplace environment − air Sodium hydroxide concentration/content Flame atomic absorption spectrometry (FAAS) Range Range PN-Z-04435:2011","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"范围","range":"(0,012 – 2,420) mg/m3"},{"name":"范围","range":"(0,0087 – 1,7400) mg w próbce"}],"search_zh":"工作环境 − 空气 氢氧化钠的浓度/含量 火焰原子吸收光谱法（FAAS） 范围 范围 PN-Z-04435:2011","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作环境 − 空气","methodology_zh":"氢氧化钠的浓度/含量"},{"_id":"6a836fb9af14b9c0e7b1ec1c","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość kobaltu i jego związków nieorganicznych w przeliczeniu na Co","parameters":[{"name":"Zakres","range":"(0,002 – 0,042) mg/m3"},{"name":"Zakres","range":"(0,0013 – 0,0300) mg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie/zawartość kobaltu i jego związków nieorganicznych w przeliczeniu na Co\nZakres:\nZakres (0,002 – 0,042) mg/m3\nZakres (0,0013 – 0,0300) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04291:2003","norm_bases":["PN-Z-04291:2003"],"lab_section":"Pracownia Środowiska Pracy PP8","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość kobaltu i jego związków nieorganicznych w przeliczeniu na Co\nZakres:\nZakres (0,002 – 0,042) mg/m3\nZakres (0,0013 – 0,0300) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04291:2003 Srodowisko pracy − powietrze Stezenie/zawartosc kobaltu i jego zwiazkow nieorganicznych w przeliczeniu na Co\nZakres:\nZakres (0,002 – 0,042) mg/m3\nZakres (0,0013 – 0,0300) mg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04291:2003","categories":["environment"],"row_index":261,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of cobalt and its inorganic compounds calculated as Co","parameters_en":[{"name":"Range","range":"(0,002 – 0,042) mg/m3"},{"name":"Range","range":"(0,0013 – 0,0300) mg w próbce"}],"search_en":"Workplace environment − air Concentration/content of cobalt and its inorganic compounds calculated as Co Flame atomic absorption spectrometry (FAAS) Range Range PN-Z-04291:2003","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"范围","range":"(0,002 – 0,042) mg/m3"},{"name":"范围","range":"(0,0013 – 0,0300) mg w próbce"}],"search_zh":"工作环境 − 空气 火焰原子吸收光谱法（FAAS） 范围 范围 PN-Z-04291:2003","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作环境 − 空气"},{"_id":"6a836fb9af14b9c0e7b1ec1d","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Liczba oktanowa motorowa (MON) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Liczba oktanowa motorowa (MON) (z obliczeń)","reference":"PN-EN 589:2024-08 załącznik B","norm_bases":["PN-EN 589:2024-08 załącznik B"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Liczba oktanowa motorowa (MON) (z obliczeń) PN-EN 589:2024-08 załącznik B Paliwa gazowe: skroplone gazy weglowodorowe, LPG Liczba oktanowa motorowa (MON) (z obliczen) PN-EN 589:2024-08 zalacznik B","categories":["petro"],"row_index":262,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Motor octane number (MON) (calculated)","search_en":"Gaseous fuels: liquefied petroleum gases, LPG Motor octane number (MON) (calculated) PN-EN 589:2024-08 załącznik B","test_object_en":"Gaseous fuels: liquefied petroleum gases, LPG","search_zh":"气体燃料：液化石油气（LPG） 马达法辛烷值（MON）（由计算得出） PN-EN 589:2024-08 załącznik B","test_object_zh":"气体燃料：液化石油气（LPG）","methodology_zh":"马达法辛烷值（MON）（由计算得出）"},{"_id":"6a836fb9af14b9c0e7b1ec1e","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Całkowita zawartość siarki","parameters":[{"name":"Zakres","range":"(1,0 – 55,0) mg/kg"},{"name":"Zakres","range":"(0,0001 – 0,0055) %(m/m)"}],"technique":"Metoda fluorescencji w nadfiolecie","techniques":["Metoda fluorescencji w nadfiolecie"],"computed":[],"activity":"Całkowita zawartość siarki\nZakres:\nZakres (1,0 – 55,0) mg/kg\nZakres (0,0001 – 0,0055) %(m/m)\nMetoda fluorescencji w nadfiolecie","reference":"ASTM D 6667-21","norm_bases":["ASTM D 6667-21"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Całkowita zawartość siarki\nZakres:\nZakres (1,0 – 55,0) mg/kg\nZakres (0,0001 – 0,0055) %(m/m)\nMetoda fluorescencji w nadfiolecie ASTM D 6667-21 Paliwa gazowe: skroplone gazy weglowodorowe, LPG Calkowita zawartosc siarki\nZakres:\nZakres (1,0 – 55,0) mg/kg\nZakres (0,0001 – 0,0055) %(m/m)\nMetoda fluorescencji w nadfiolecie ASTM D 6667-21","categories":["petro"],"row_index":263,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total sulphur content","parameters_en":[{"name":"Range","range":"(1,0 – 55,0) mg/kg"},{"name":"Range","range":"(0,0001 – 0,0055) %(m/m)"}],"search_en":"Gaseous fuels: liquefied petroleum gases, LPG Total sulphur content Ultraviolet fluorescence method Range Range ASTM D 6667-21","technique_en":"Ultraviolet fluorescence method","test_object_en":"Gaseous fuels: liquefied petroleum gases, LPG","parameters_zh":[{"name":"范围","range":"(1,0 – 55,0) mg/kg"},{"name":"范围","range":"(0,0001 – 0,0055) %(m/m)"}],"search_zh":"气体燃料：液化石油气（LPG） 紫外荧光法 范围 范围 ASTM D 6667-21","test_object_zh":"气体燃料：液化石油气（LPG）","technique_zh":"紫外荧光法"},{"_id":"6a836fb9af14b9c0e7b1ec1f","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Prężność par oszacowana w temperaturze 40 oC (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Prężność par oszacowana w temperaturze 40 oC (z obliczeń)","reference":"PN-EN ISO 8973:2000+A1:2020-10 | PN-EN 589:2024-08 załącznik C","norm_bases":["PN-EN ISO 8973:2000+A1:2020-10","PN-EN 589:2024-08 załącznik C"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Prężność par oszacowana w temperaturze 40 oC (z obliczeń) PN-EN ISO 8973:2000+A1:2020-10 | PN-EN 589:2024-08 załącznik C Paliwa gazowe: skroplone gazy weglowodorowe, LPG Preznosc par oszacowana w temperaturze 40 oC (z obliczen) PN-EN ISO 8973:2000+A1:2020-10 | PN-EN 589:2024-08 zalacznik C","categories":["petro"],"row_index":264,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Vapour pressure estimated at the temperature 40 oC (calculated)","search_en":"Gaseous fuels: liquefied petroleum gases, LPG Vapour pressure estimated at the temperature 40 oC (calculated) PN-EN ISO 8973:2000+A1:2020-10 | PN-EN 589:2024-08 załącznik C","test_object_en":"Gaseous fuels: liquefied petroleum gases, LPG","search_zh":"气体燃料：液化石油气（LPG） PN-EN ISO 8973:2000+A1:2020-10 | PN-EN 589:2024-08 załącznik C","test_object_zh":"气体燃料：液化石油气（LPG）"},{"_id":"6a836fb9af14b9c0e7b1ec20","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Temperatura, w której oszacowana względna prężność par jest nie mniejsza niż 150 kPa (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura, w której oszacowana względna prężność par jest nie mniejsza niż 150 kPa (z obliczeń)","reference":"PN-EN ISO 8973:2000+A1:2020-10 | PN-EN 589:2019-04 załącznik C","norm_bases":["PN-EN ISO 8973:2000+A1:2020-10","PN-EN 589:2019-04 załącznik C"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Temperatura, w której oszacowana względna prężność par jest nie mniejsza niż 150 kPa (z obliczeń) PN-EN ISO 8973:2000+A1:2020-10 | PN-EN 589:2019-04 załącznik C Paliwa gazowe: skroplone gazy weglowodorowe, LPG Temperatura, w ktorej oszacowana wzgledna preznosc par jest nie mniejsza niz 150 kPa (z obliczen) PN-EN ISO 8973:2000+A1:2020-10 | PN-EN 589:2019-04 zalacznik C","categories":["petro"],"row_index":265,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Temperature at which the estimated relative vapour pressure is not less than 150 kPa (calculated)","search_en":"Gaseous fuels: liquefied petroleum gases, LPG Temperature at which the estimated relative vapour pressure is not less than 150 kPa (calculated) PN-EN ISO 8973:2000+A1:2020-10 | PN-EN 589:2019-04 załącznik C","test_object_en":"Gaseous fuels: liquefied petroleum gases, LPG","search_zh":"气体燃料：液化石油气（LPG） 估算相对蒸气压不低于 150 kPa 时的温度（由计算得出） PN-EN ISO 8973:2000+A1:2020-10 | PN-EN 589:2019-04 załącznik C","test_object_zh":"气体燃料：液化石油气（LPG）","methodology_zh":"估算相对蒸气压不低于 150 kPa 时的温度（由计算得出）"},{"_id":"6a836fb9af14b9c0e7b1ec21","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Prężność par oszacowana w temperaturze (-10)°C, (-5)°C, 0°C, 10°C, 20°C (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Prężność par oszacowana w temperaturze (-10)°C, (-5)°C, 0°C, 10°C, 20°C (z obliczeń)","reference":"PN-EN ISO 8973:2000+A1:2020-10 | PN-EN 589:2024-08 załącznik C","norm_bases":["PN-EN ISO 8973:2000+A1:2020-10","PN-EN 589:2024-08 załącznik C"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Prężność par oszacowana w temperaturze (-10)°C, (-5)°C, 0°C, 10°C, 20°C (z obliczeń) PN-EN ISO 8973:2000+A1:2020-10 | PN-EN 589:2024-08 załącznik C Paliwa gazowe: skroplone gazy weglowodorowe, LPG Preznosc par oszacowana w temperaturze (-10)°C, (-5)°C, 0°C, 10°C, 20°C (z obliczen) PN-EN ISO 8973:2000+A1:2020-10 | PN-EN 589:2024-08 zalacznik C","categories":["petro"],"row_index":266,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Vapour pressure estimated at the temperature (-10)°C, (-5)°C, 0°C, 10°C, 20°C (calculated)","search_en":"Gaseous fuels: liquefied petroleum gases, LPG Vapour pressure estimated at the temperature (-10)°C, (-5)°C, 0°C, 10°C, 20°C (calculated) PN-EN ISO 8973:2000+A1:2020-10 | PN-EN 589:2024-08 załącznik C","test_object_en":"Gaseous fuels: liquefied petroleum gases, LPG","search_zh":"气体燃料：液化石油气（LPG） PN-EN ISO 8973:2000+A1:2020-10 | PN-EN 589:2024-08 załącznik C","test_object_zh":"气体燃料：液化石油气（LPG）"},{"_id":"6a836fb9af14b9c0e7b1ec22","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Skład węglowodorowy","parameters":[{"name":"Zakres","range":"(0,1 – 100,0) %(m/m)"},{"name":"Zakres","range":"(0,1 – 100,0) %(mol)"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Skład węglowodorowy\nZakres:\nZakres (0,1 – 100,0) %(m/m)\nZakres (0,1 – 100,0) %(mol)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-ISO 7941:1993+Ap1:2002 | PN-EN 27941:2015-12","norm_bases":["PN-ISO 7941:1993+Ap1:2002","PN-EN 27941:2015-12"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Skład węglowodorowy\nZakres:\nZakres (0,1 – 100,0) %(m/m)\nZakres (0,1 – 100,0) %(mol)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-ISO 7941:1993+Ap1:2002 | PN-EN 27941:2015-12 Paliwa gazowe: skroplone gazy weglowodorowe, LPG Sklad weglowodorowy\nZakres:\nZakres (0,1 – 100,0) %(m/m)\nZakres (0,1 – 100,0) %(mol)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-ISO 7941:1993+Ap1:2002 | PN-EN 27941:2015-12","categories":["petro"],"row_index":267,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrocarbon composition","parameters_en":[{"name":"Range","range":"(0,1 – 100,0) %(m/m)"},{"name":"Range","range":"(0,1 – 100,0) %(mol)"}],"search_en":"Gaseous fuels: liquefied petroleum gases, LPG Hydrocarbon composition Gas chromatography with flame ionization detection (GC-FID) Range Range PN-ISO 7941:1993+Ap1:2002 | PN-EN 27941:2015-12","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Gaseous fuels: liquefied petroleum gases, LPG","parameters_zh":[{"name":"范围","range":"(0,1 – 100,0) %(m/m)"},{"name":"范围","range":"(0,1 – 100,0) %(mol)"}],"search_zh":"气体燃料：液化石油气（LPG） 烃类组成 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-ISO 7941:1993+Ap1:2002 | PN-EN 27941:2015-12","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"气体燃料：液化石油气（LPG）","methodology_zh":"烃类组成"},{"_id":"6a836fb9af14b9c0e7b1ec23","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Całkowita zawartość dienów","parameters":[{"name":"Zakres","range":"(0,1 – 2,1) %(m/m)"},{"name":"Zakres","range":"(0,1 – 2,0) %(mol)"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Całkowita zawartość dienów\nZakres:\nZakres (0,1 – 2,1) %(m/m)\nZakres (0,1 – 2,0) %(mol)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-ISO 7941:1993+Ap1:2002 | PN-EN 27941:2015-12","norm_bases":["PN-ISO 7941:1993+Ap1:2002","PN-EN 27941:2015-12"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Całkowita zawartość dienów\nZakres:\nZakres (0,1 – 2,1) %(m/m)\nZakres (0,1 – 2,0) %(mol)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-ISO 7941:1993+Ap1:2002 | PN-EN 27941:2015-12 Paliwa gazowe: skroplone gazy weglowodorowe, LPG Calkowita zawartosc dienow\nZakres:\nZakres (0,1 – 2,1) %(m/m)\nZakres (0,1 – 2,0) %(mol)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-ISO 7941:1993+Ap1:2002 | PN-EN 27941:2015-12","categories":["petro"],"row_index":268,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total diene content","parameters_en":[{"name":"Range","range":"(0,1 – 2,1) %(m/m)"},{"name":"Range","range":"(0,1 – 2,0) %(mol)"}],"search_en":"Gaseous fuels: liquefied petroleum gases, LPG Total diene content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-ISO 7941:1993+Ap1:2002 | PN-EN 27941:2015-12","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Gaseous fuels: liquefied petroleum gases, LPG","parameters_zh":[{"name":"范围","range":"(0,1 – 2,1) %(m/m)"},{"name":"范围","range":"(0,1 – 2,0) %(mol)"}],"search_zh":"气体燃料：液化石油气（LPG） 二烯烃总含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-ISO 7941:1993+Ap1:2002 | PN-EN 27941:2015-12","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"气体燃料：液化石油气（LPG）","methodology_zh":"二烯烃总含量"},{"_id":"6a836fb9af14b9c0e7b1ec24","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Działanie korodujące na miedź","parameters":[{"name":"klasa korozji","range":"(1 – 4)"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Działanie korodujące na miedź\nklasa korozji (1 – 4)\nMetoda wizualna","reference":"PN-EN ISO 6251:2001","norm_bases":["PN-EN ISO 6251:2001"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Działanie korodujące na miedź\nklasa korozji (1 – 4)\nMetoda wizualna PN-EN ISO 6251:2001 Paliwa gazowe: skroplone gazy weglowodorowe, LPG Dzialanie korodujace na miedz\nklasa korozji (1 – 4)\nMetoda wizualna PN-EN ISO 6251:2001","categories":["petro","materials"],"row_index":269,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Copper strip corrosion","parameters_en":[{"name":"corrosion class","range":"(1 – 4)"}],"search_en":"Gaseous fuels: liquefied petroleum gases, LPG Copper strip corrosion Visual method corrosion class PN-EN ISO 6251:2001","technique_en":"Visual method","test_object_en":"Gaseous fuels: liquefied petroleum gases, LPG","search_zh":"气体燃料：液化石油气（LPG） 铜片腐蚀 目视法 腐蚀等级 PN-EN ISO 6251:2001","technique_zh":"目视法","test_object_zh":"气体燃料：液化石油气（LPG）","parameters_zh":[{"name":"腐蚀等级","range":"(1 – 4)"}],"methodology_zh":"铜片腐蚀"},{"_id":"6a836fb9af14b9c0e7b1ec25","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Obecność siarkowodoru","parameters":[],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Obecność siarkowodoru\nMetoda wizualna","reference":"PN-EN ISO 8819:2000","norm_bases":["PN-EN ISO 8819:2000"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Obecność siarkowodoru\nMetoda wizualna PN-EN ISO 8819:2000 Paliwa gazowe: skroplone gazy weglowodorowe, LPG Obecnosc siarkowodoru\nMetoda wizualna PN-EN ISO 8819:2000","categories":["petro"],"row_index":270,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of hydrogen sulfide","search_en":"Gaseous fuels: liquefied petroleum gases, LPG Presence of hydrogen sulfide Visual method PN-EN ISO 8819:2000","technique_en":"Visual method","test_object_en":"Gaseous fuels: liquefied petroleum gases, LPG","search_zh":"气体燃料：液化石油气（LPG） 硫化氢的检出 目视法 PN-EN ISO 8819:2000","technique_zh":"目视法","test_object_zh":"气体燃料：液化石油气（LPG）","methodology_zh":"硫化氢的检出"},{"_id":"6a836fb9af14b9c0e7b1ec26","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Obecność wody","parameters":[],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Obecność wody\nMetoda wizualna","reference":"PN-EN 15469:2009","norm_bases":["PN-EN 15469:2009"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Obecność wody\nMetoda wizualna PN-EN 15469:2009 Paliwa gazowe: skroplone gazy weglowodorowe, LPG Obecnosc wody\nMetoda wizualna PN-EN 15469:2009","categories":["petro","water"],"row_index":271,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of water","search_en":"Gaseous fuels: liquefied petroleum gases, LPG Presence of water Visual method PN-EN 15469:2009","technique_en":"Visual method","test_object_en":"Gaseous fuels: liquefied petroleum gases, LPG","search_zh":"气体燃料：液化石油气（LPG） 水的检出 目视法 PN-EN 15469:2009","technique_zh":"目视法","test_object_zh":"气体燃料：液化石油气（LPG）","methodology_zh":"水的检出"},{"_id":"6a836fb9af14b9c0e7b1ec27","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Zapach","parameters":[],"technique":"Metoda organoleptyczna","techniques":["Metoda organoleptyczna"],"computed":[],"activity":"Zapach\nMetoda organoleptyczna","reference":"PN-EN 589:2024-08 załącznik A","norm_bases":["PN-EN 589:2024-08 załącznik A"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Zapach\nMetoda organoleptyczna PN-EN 589:2024-08 załącznik A Paliwa gazowe: skroplone gazy weglowodorowe, LPG Zapach\nMetoda organoleptyczna PN-EN 589:2024-08 zalacznik A","categories":["petro"],"row_index":272,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Odour","search_en":"Gaseous fuels: liquefied petroleum gases, LPG Odour Organoleptic method PN-EN 589:2024-08 załącznik A","technique_en":"Organoleptic method","test_object_en":"Gaseous fuels: liquefied petroleum gases, LPG","search_zh":"气体燃料：液化石油气（LPG） 气味 感官法 PN-EN 589:2024-08 załącznik A","test_object_zh":"气体燃料：液化石油气（LPG）","technique_zh":"感官法","methodology_zh":"气味"},{"_id":"6a836fb9af14b9c0e7b1ec28","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Wartość opałowa (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wartość opałowa (z obliczeń)","reference":"PN-C-96008:1998 p. 4.4.8","norm_bases":["PN-C-96008:1998 p. 4.4.8"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Wartość opałowa (z obliczeń) PN-C-96008:1998 p. 4.4.8 Paliwa gazowe: skroplone gazy weglowodorowe, LPG Wartosc opalowa (z obliczen) PN-C-96008:1998 p. 4.4.8","categories":["petro"],"row_index":273,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Net calorific value (calculated)","search_en":"Gaseous fuels: liquefied petroleum gases, LPG Net calorific value (calculated) PN-C-96008:1998 p. 4.4.8","test_object_en":"Gaseous fuels: liquefied petroleum gases, LPG","methodology_zh":"低位发热量（计算值）","search_zh":"气体燃料：液化石油气（LPG） 低位发热量（计算值） PN-C-96008:1998 p. 4.4.8","test_object_zh":"气体燃料：液化石油气（LPG）"},{"_id":"6a836fb9af14b9c0e7b1ec29","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Prężność absolutna par w temp. (-15) °C (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Prężność absolutna par w temp. (-15) °C (z obliczeń)","reference":"PN-C-96008:1998 p. 4.4.10","norm_bases":["PN-C-96008:1998 p. 4.4.10"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Prężność absolutna par w temp. (-15) °C (z obliczeń) PN-C-96008:1998 p. 4.4.10 Paliwa gazowe: skroplone gazy weglowodorowe, LPG Preznosc absolutna par w temp. (-15) °C (z obliczen) PN-C-96008:1998 p. 4.4.10","categories":["petro"],"row_index":274,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Absolute vapour pressure at temp. (-15) °C (calculated)","search_en":"Gaseous fuels: liquefied petroleum gases, LPG Absolute vapour pressure at temp. (-15) °C (calculated) PN-C-96008:1998 p. 4.4.10","test_object_en":"Gaseous fuels: liquefied petroleum gases, LPG","search_zh":"气体燃料：液化石油气（LPG） PN-C-96008:1998 p. 4.4.10","test_object_zh":"气体燃料：液化石油气（LPG）"},{"_id":"6a836fb9af14b9c0e7b1ec2a","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Prężność absolutna par w temp. 40 °C (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Prężność absolutna par w temp. 40 °C (z obliczeń)","reference":"PN-C-96008:1998 p. 4.4.10","norm_bases":["PN-C-96008:1998 p. 4.4.10"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Prężność absolutna par w temp. 40 °C (z obliczeń) PN-C-96008:1998 p. 4.4.10 Paliwa gazowe: skroplone gazy weglowodorowe, LPG Preznosc absolutna par w temp. 40 °C (z obliczen) PN-C-96008:1998 p. 4.4.10","categories":["petro"],"row_index":275,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Absolute vapour pressure at temp. 40 °C (calculated)","search_en":"Gaseous fuels: liquefied petroleum gases, LPG Absolute vapour pressure at temp. 40 °C (calculated) PN-C-96008:1998 p. 4.4.10","test_object_en":"Gaseous fuels: liquefied petroleum gases, LPG","search_zh":"气体燃料：液化石油气（LPG） PN-C-96008:1998 p. 4.4.10","test_object_zh":"气体燃料：液化石油气（LPG）"},{"_id":"6a836fb9af14b9c0e7b1ec2b","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Prężność absolutna par w temp. 70 °C (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Prężność absolutna par w temp. 70 °C (z obliczeń)","reference":"PN-C-96008:1998 p. 4.4.10","norm_bases":["PN-C-96008:1998 p. 4.4.10"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Prężność absolutna par w temp. 70 °C (z obliczeń) PN-C-96008:1998 p. 4.4.10 Paliwa gazowe: skroplone gazy weglowodorowe, LPG Preznosc absolutna par w temp. 70 °C (z obliczen) PN-C-96008:1998 p. 4.4.10","categories":["petro"],"row_index":276,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Absolute vapour pressure at temp. 70 °C (calculated)","search_en":"Gaseous fuels: liquefied petroleum gases, LPG Absolute vapour pressure at temp. 70 °C (calculated) PN-C-96008:1998 p. 4.4.10","test_object_en":"Gaseous fuels: liquefied petroleum gases, LPG","search_zh":"气体燃料：液化石油气（LPG） PN-C-96008:1998 p. 4.4.10","test_object_zh":"气体燃料：液化石油气（LPG）"},{"_id":"6a836fb9af14b9c0e7b1ec2c","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Gęstość w temp. 15,6 °C (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Gęstość w temp. 15,6 °C (z obliczeń)","reference":"PN-C-96008:1998 p. 4.4.9","norm_bases":["PN-C-96008:1998 p. 4.4.9"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Gęstość w temp. 15,6 °C (z obliczeń) PN-C-96008:1998 p. 4.4.9 Paliwa gazowe: skroplone gazy weglowodorowe, LPG Gestosc w temp. 15,6 °C (z obliczen) PN-C-96008:1998 p. 4.4.9","categories":["petro"],"row_index":277,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Density at temp. 15,6 °C (calculated)","search_en":"Gaseous fuels: liquefied petroleum gases, LPG Density at temp. 15,6 °C (calculated) PN-C-96008:1998 p. 4.4.9","test_object_en":"Gaseous fuels: liquefied petroleum gases, LPG","search_zh":"气体燃料：液化石油气（LPG） PN-C-96008:1998 p. 4.4.9","test_object_zh":"气体燃料：液化石油气（LPG）"},{"_id":"6a836fb9af14b9c0e7b1ec2d","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Rozpuszczalna pozostałość","parameters":[{"name":"Zakres","range":"(5 – 100) mg/kg"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Rozpuszczalna pozostałość\nZakres (5 – 100) mg/kg\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 15470:2017-08","norm_bases":["PN-EN 15470:2017-08"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Rozpuszczalna pozostałość\nZakres (5 – 100) mg/kg\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 15470:2017-08 Paliwa gazowe: skroplone gazy weglowodorowe, LPG Rozpuszczalna pozostalosc\nZakres (5 – 100) mg/kg\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 15470:2017-08","categories":["petro"],"row_index":278,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Soluble residue","parameters_en":[{"name":"Range","range":"(5 – 100) mg/kg"}],"search_en":"Gaseous fuels: liquefied petroleum gases, LPG Soluble residue Gas chromatography with flame ionization detection (GC-FID) Range PN-EN 15470:2017-08","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Gaseous fuels: liquefied petroleum gases, LPG","parameters_zh":[{"name":"范围","range":"(5 – 100) mg/kg"}],"search_zh":"气体燃料：液化石油气（LPG） 可溶性残余物 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-EN 15470:2017-08","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"气体燃料：液化石油气（LPG）","methodology_zh":"可溶性残余物"},{"_id":"6a836fb9af14b9c0e7b1ec2e","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Całkowita zawartość dienów","parameters":[{"name":"Zakres","range":"(0,01 – 0,50) %(m/m)"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Całkowita zawartość dienów\nZakres (0,01 – 0,50) %(m/m)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"DIN 51619:2004-02","norm_bases":["DIN 51619:2004-02"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Całkowita zawartość dienów\nZakres (0,01 – 0,50) %(m/m)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) DIN 51619:2004-02 Paliwa gazowe: skroplone gazy weglowodorowe, LPG Calkowita zawartosc dienow\nZakres (0,01 – 0,50) %(m/m)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) DIN 51619:2004-02","categories":["petro"],"row_index":279,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total diene content","parameters_en":[{"name":"Range","range":"(0,01 – 0,50) %(m/m)"}],"search_en":"Gaseous fuels: liquefied petroleum gases, LPG Total diene content Gas chromatography with flame ionization detection (GC-FID) Range DIN 51619:2004-02","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Gaseous fuels: liquefied petroleum gases, LPG","parameters_zh":[{"name":"范围","range":"(0,01 – 0,50) %(m/m)"}],"search_zh":"气体燃料：液化石油气（LPG） 二烯烃总含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 DIN 51619:2004-02","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"气体燃料：液化石油气（LPG）","methodology_zh":"二烯烃总含量"},{"_id":"6a836fb9af14b9c0e7b1ec2f","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Zawartość 1,3 butadienu","parameters":[{"name":"Zakres","range":"(0,01 – 0,50) %(m/m)"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość 1,3 butadienu\nZakres (0,01 – 0,50) %(m/m)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"DIN 51619:2004-02","norm_bases":["DIN 51619:2004-02"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Zawartość 1,3 butadienu\nZakres (0,01 – 0,50) %(m/m)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) DIN 51619:2004-02 Paliwa gazowe: skroplone gazy weglowodorowe, LPG Zawartosc 1,3 butadienu\nZakres (0,01 – 0,50) %(m/m)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) DIN 51619:2004-02","categories":["petro"],"row_index":280,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"1,3-butadiene content","parameters_en":[{"name":"Range","range":"(0,01 – 0,50) %(m/m)"}],"search_en":"Gaseous fuels: liquefied petroleum gases, LPG 1,3-butadiene content Gas chromatography with flame ionization detection (GC-FID) Range DIN 51619:2004-02","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Gaseous fuels: liquefied petroleum gases, LPG","parameters_zh":[{"name":"范围","range":"(0,01 – 0,50) %(m/m)"}],"search_zh":"气体燃料：液化石油气（LPG） 1,3-丁二烯含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 DIN 51619:2004-02","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"气体燃料：液化石油气（LPG）","methodology_zh":"1,3-丁二烯含量"},{"_id":"6a836fb9af14b9c0e7b1ec30","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Skład węglowodorowy","parameters":[{"name":"Zakres","range":"(0,10 – 100,00) %(m/m) dla"},{"name":"każdego ze składników"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Skład węglowodorowy\nZakres:\nZakres (0,10 – 100,00) %(m/m) dla\nkażdego ze składników\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"DIN 51619:2004-02","norm_bases":["DIN 51619:2004-02"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Skład węglowodorowy\nZakres:\nZakres (0,10 – 100,00) %(m/m) dla\nkażdego ze składników\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) DIN 51619:2004-02 Paliwa gazowe: skroplone gazy weglowodorowe, LPG Sklad weglowodorowy\nZakres:\nZakres (0,10 – 100,00) %(m/m) dla\nkazdego ze skladnikow\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) DIN 51619:2004-02","categories":["petro"],"row_index":281,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrocarbon composition","parameters_en":[{"name":"Range","range":"(0,10 – 100,00) %(m/m) dla"},{"name":"each of the components"}],"search_en":"Gaseous fuels: liquefied petroleum gases, LPG Hydrocarbon composition Gas chromatography with flame ionization detection (GC-FID) Range each of the components DIN 51619:2004-02","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Gaseous fuels: liquefied petroleum gases, LPG","parameters_zh":[{"name":"范围","range":"(0,10 – 100,00) %(m/m) dla"},{"name":"każdego ze składników"}],"search_zh":"气体燃料：液化石油气（LPG） 烃类组成 气相色谱-氢火焰离子化检测法（GC-FID） 范围 DIN 51619:2004-02","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"气体燃料：液化石油气（LPG）","methodology_zh":"烃类组成"},{"_id":"6a836fb9af14b9c0e7b1ec31","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe","methodology":"Obecność siarkowodoru","parameters":[],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Obecność siarkowodoru\nMetoda wizualna","reference":"PN-C-96008:1998 p. 4.4.2","norm_bases":["PN-C-96008:1998 p. 4.4.2"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe Obecność siarkowodoru\nMetoda wizualna PN-C-96008:1998 p. 4.4.2 Paliwa gazowe: skroplone gazy weglowodorowe Obecnosc siarkowodoru\nMetoda wizualna PN-C-96008:1998 p. 4.4.2","categories":["petro"],"row_index":282,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of hydrogen sulfide","search_en":"Gaseous fuels: liquefied petroleum gases Presence of hydrogen sulfide Visual method PN-C-96008:1998 p. 4.4.2","technique_en":"Visual method","test_object_en":"Gaseous fuels: liquefied petroleum gases","search_zh":"气体燃料：液化石油气 硫化氢的检出 目视法 PN-C-96008:1998 p. 4.4.2","technique_zh":"目视法","methodology_zh":"硫化氢的检出","test_object_zh":"气体燃料：液化石油气"},{"_id":"6a836fb9af14b9c0e7b1ec32","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe","methodology":"Zawartość oleju mineralnego","parameters":[{"name":"Zakres","range":"(0,0003 – 0,0050) %(m/m)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość oleju mineralnego\nZakres (0,0003 – 0,0050) %(m/m)\nMetoda wagowa","reference":"PN-C-96008:1998 p. 4.4.4","norm_bases":["PN-C-96008:1998 p. 4.4.4"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe Zawartość oleju mineralnego\nZakres (0,0003 – 0,0050) %(m/m)\nMetoda wagowa PN-C-96008:1998 p. 4.4.4 Paliwa gazowe: skroplone gazy weglowodorowe Zawartosc oleju mineralnego\nZakres (0,0003 – 0,0050) %(m/m)\nMetoda wagowa PN-C-96008:1998 p. 4.4.4","categories":["petro"],"row_index":283,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mineral oil content","parameters_en":[{"name":"Range","range":"(0,0003 – 0,0050) %(m/m)"}],"search_en":"Gaseous fuels: liquefied petroleum gases Mineral oil content Gravimetric method Range PN-C-96008:1998 p. 4.4.4","technique_en":"Gravimetric method","test_object_en":"Gaseous fuels: liquefied petroleum gases","parameters_zh":[{"name":"范围","range":"(0,0003 – 0,0050) %(m/m)"}],"search_zh":"气体燃料：液化石油气 矿物油含量 重量法 范围 PN-C-96008:1998 p. 4.4.4","technique_zh":"重量法","methodology_zh":"矿物油含量","test_object_zh":"气体燃料：液化石油气"},{"_id":"6a836fb9af14b9c0e7b1ec33","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe","methodology":"Obecność wody","parameters":[],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Obecność wody\nMetoda wizualna","reference":"PN-C-96008:1998 p. 4.4.5","norm_bases":["PN-C-96008:1998 p. 4.4.5"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe Obecność wody\nMetoda wizualna PN-C-96008:1998 p. 4.4.5 Paliwa gazowe: skroplone gazy weglowodorowe Obecnosc wody\nMetoda wizualna PN-C-96008:1998 p. 4.4.5","categories":["water","petro"],"row_index":284,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of water","search_en":"Gaseous fuels: liquefied petroleum gases Presence of water Visual method PN-C-96008:1998 p. 4.4.5","technique_en":"Visual method","test_object_en":"Gaseous fuels: liquefied petroleum gases","search_zh":"气体燃料：液化石油气 水的检出 目视法 PN-C-96008:1998 p. 4.4.5","technique_zh":"目视法","methodology_zh":"水的检出","test_object_zh":"气体燃料：液化石油气"},{"_id":"6a836fb9af14b9c0e7b1ec34","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe","methodology":"Obecność amoniaku","parameters":[],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Obecność amoniaku\nMetoda wizualna","reference":"PN-C-96008:1998 p. 4.4.6","norm_bases":["PN-C-96008:1998 p. 4.4.6"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe Obecność amoniaku\nMetoda wizualna PN-C-96008:1998 p. 4.4.6 Paliwa gazowe: skroplone gazy weglowodorowe Obecnosc amoniaku\nMetoda wizualna PN-C-96008:1998 p. 4.4.6","categories":["petro"],"row_index":285,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of ammonia","search_en":"Gaseous fuels: liquefied petroleum gases Presence of ammonia Visual method PN-C-96008:1998 p. 4.4.6","technique_en":"Visual method","test_object_en":"Gaseous fuels: liquefied petroleum gases","search_zh":"气体燃料：液化石油气 目视法 PN-C-96008:1998 p. 4.4.6","technique_zh":"目视法","test_object_zh":"气体燃料：液化石油气"},{"_id":"6a836fb9af14b9c0e7b1ec35","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: gazy z procesów technologicznych: gazy opałowe, gazy wodorowe, gazy pooksydacyjne, gazy węglowodorowe","methodology":"Skład szczegółowy","parameters":[{"name":"Węglowodory od C1 do C6"},{"name":"Zakres","range":"(0,10 – 99,90) % (mol/mol)"},{"name":"Tlen","range":"(0,10 – 20,00) %(mol/mol)"},{"name":"Azot","range":"(0,10 – 90,00) %(mol/mol)"},{"name":"CO2","range":"(0,10 – 45,00) %(mol/mol)"},{"name":"CO","range":"(0,10 – 1,00) %(mol/mol)"},{"name":"H2","range":"(0,10 – 99,70) %(mol/mol)"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną i termokonduktometryczną (GC-FID/TCD)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną i termokonduktometryczną (GC-FID/TCD)"],"computed":[],"activity":"Skład szczegółowy\nZakres:\nWęglowodory od C1 do C6\nZakres (0,10 – 99,90) % (mol/mol)\nTlen (0,10 – 20,00) %(mol/mol)\nAzot (0,10 – 90,00) %(mol/mol)\nCO2 (0,10 – 45,00) %(mol/mol)\nCO (0,10 – 1,00) %(mol/mol)\nH2 (0,10 – 99,70) %(mol/mol)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną i termokonduktometryczną (GC-FID/TCD)","reference":"UOP 539-12","norm_bases":["UOP 539-12"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: gazy z procesów technologicznych: gazy opałowe, gazy wodorowe, gazy pooksydacyjne, gazy węglowodorowe Skład szczegółowy\nZakres:\nWęglowodory od C1 do C6\nZakres (0,10 – 99,90) % (mol/mol)\nTlen (0,10 – 20,00) %(mol/mol)\nAzot (0,10 – 90,00) %(mol/mol)\nCO2 (0,10 – 45,00) %(mol/mol)\nCO (0,10 – 1,00) %(mol/mol)\nH2 (0,10 – 99,70) %(mol/mol)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną i termokonduktometryczną (GC-FID/TCD) UOP 539-12 Paliwa gazowe: gazy z procesow technologicznych: gazy opalowe, gazy wodorowe, gazy pooksydacyjne, gazy weglowodorowe Sklad szczegolowy\nZakres:\nWeglowodory od C1 do C6\nZakres (0,10 – 99,90) % (mol/mol)\nTlen (0,10 – 20,00) %(mol/mol)\nAzot (0,10 – 90,00) %(mol/mol)\nCO2 (0,10 – 45,00) %(mol/mol)\nCO (0,10 – 1,00) %(mol/mol)\nH2 (0,10 – 99,70) %(mol/mol)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna i termokonduktometryczna (GC-FID/TCD) UOP 539-12","categories":["petro"],"row_index":286,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Detailed composition","parameters_en":[{"name":"Hydrocarbons from C1 to C6"},{"name":"Range","range":"(0,10 – 99,90) % (mol/mol)"},{"name":"Oxygen","range":"(0,10 – 20,00) %(mol/mol)"},{"name":"Nitrogen","range":"(0,10 – 90,00) %(mol/mol)"},{"name":"CO2","range":"(0,10 – 45,00) %(mol/mol)"},{"name":"CO","range":"(0,10 – 1,00) %(mol/mol)"},{"name":"H2","range":"(0,10 – 99,70) %(mol/mol)"}],"search_en":"Gaseous fuels: gases from technological processes: fuel gases, hydrogen gases, post-oxidation gases, hydrocarbon gases Detailed composition Gas chromatography with flame ionization and thermal conductivity detection (GC-FID/TCD) Hydrocarbons from C1 to C6 Range Oxygen Nitrogen CO2 CO H2 UOP 539-12","technique_en":"Gas chromatography with flame ionization and thermal conductivity detection (GC-FID/TCD)","test_object_en":"Gaseous fuels: gases from technological processes: fuel gases, hydrogen gases, post-oxidation gases, hydrocarbon gases","parameters_zh":[{"name":"Węglowodory od C1 do C6"},{"name":"范围","range":"(0,10 – 99,90) % (mol/mol)"},{"name":"氧","range":"(0,10 – 20,00) %(mol/mol)"},{"name":"氮","range":"(0,10 – 90,00) %(mol/mol)"},{"name":"CO2","range":"(0,10 – 45,00) %(mol/mol)"},{"name":"CO","range":"(0,10 – 1,00) %(mol/mol)"},{"name":"H2","range":"(0,10 – 99,70) %(mol/mol)"}],"search_zh":"范围 氧 氮 CO2 CO UOP 539-12"},{"_id":"6a836fb9af14b9c0e7b1ec36","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: gazy z procesów technologicznych: gazy pooksydacyjne, gazy węglowodorowe","methodology":"Zawartość węgla pierwiastkowego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość węgla pierwiastkowego (z obliczeń)","reference":"Metoda 103 wydanie 3 z dnia 07.01.2022","norm_bases":["Metoda 103 wydanie 3 z dnia 07.01.2022"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: gazy z procesów technologicznych: gazy pooksydacyjne, gazy węglowodorowe Zawartość węgla pierwiastkowego (z obliczeń) Metoda 103 wydanie 3 z dnia 07.01.2022 Paliwa gazowe: gazy z procesow technologicznych: gazy pooksydacyjne, gazy weglowodorowe Zawartosc wegla pierwiastkowego (z obliczen) Metoda 103 wydanie 3 z dnia 07.01.2022","categories":["petro"],"row_index":287,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Elemental carbon content (calculated)","search_en":"Gaseous fuels: gases from technological processes: post-oxidation gases, hydrocarbon gases Elemental carbon content (calculated) Metoda 103 wydanie 3 z dnia 07.01.2022","test_object_en":"Gaseous fuels: gases from technological processes: post-oxidation gases, hydrocarbon gases"},{"_id":"6a836fb9af14b9c0e7b1ec37","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: gazy z procesów technologicznych: gazy pooksydacyjne, gazy węglowodorowe","methodology":"Wartość opałowa (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wartość opałowa (z obliczeń)","reference":"PN-EN ISO 6976:2016-11","norm_bases":["PN-EN ISO 6976:2016-11"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: gazy z procesów technologicznych: gazy pooksydacyjne, gazy węglowodorowe Wartość opałowa (z obliczeń) PN-EN ISO 6976:2016-11 Paliwa gazowe: gazy z procesow technologicznych: gazy pooksydacyjne, gazy weglowodorowe Wartosc opalowa (z obliczen) PN-EN ISO 6976:2016-11","categories":["petro"],"row_index":288,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Net calorific value (calculated)","search_en":"Gaseous fuels: gases from technological processes: post-oxidation gases, hydrocarbon gases Net calorific value (calculated) PN-EN ISO 6976:2016-11","test_object_en":"Gaseous fuels: gases from technological processes: post-oxidation gases, hydrocarbon gases","methodology_zh":"低位发热量（计算值）","search_zh":"低位发热量（计算值） PN-EN ISO 6976:2016-11"},{"_id":"6a836fb9af14b9c0e7b1ec38","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: gazy z procesów technologicznych: gazy pooksydacyjne, gazy węglowodorowe","methodology":"Gęstość (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Gęstość (z obliczeń)","reference":"PN-EN ISO 6976:2016-11","norm_bases":["PN-EN ISO 6976:2016-11"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: gazy z procesów technologicznych: gazy pooksydacyjne, gazy węglowodorowe Gęstość (z obliczeń) PN-EN ISO 6976:2016-11 Paliwa gazowe: gazy z procesow technologicznych: gazy pooksydacyjne, gazy weglowodorowe Gestosc (z obliczen) PN-EN ISO 6976:2016-11","categories":["petro"],"row_index":289,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Density (calculated)","search_en":"Gaseous fuels: gases from technological processes: post-oxidation gases, hydrocarbon gases Density (calculated) PN-EN ISO 6976:2016-11","test_object_en":"Gaseous fuels: gases from technological processes: post-oxidation gases, hydrocarbon gases","methodology_zh":"密度（由计算得出）","search_zh":"密度（由计算得出） PN-EN ISO 6976:2016-11"},{"_id":"6a836fb9af14b9c0e7b1ec39","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: gaz ziemny","methodology":"Skład węglowodorowy","parameters":[{"name":"Zakres","range":"(0,0002 – 99,0000) %mol"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Skład węglowodorowy\nZakres (0,0002 – 99,0000) %mol\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 27941:2015-12","norm_bases":["PN-EN 27941:2015-12"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: gaz ziemny Skład węglowodorowy\nZakres (0,0002 – 99,0000) %mol\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 27941:2015-12 Paliwa gazowe: gaz ziemny Sklad weglowodorowy\nZakres (0,0002 – 99,0000) %mol\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 27941:2015-12","categories":["petro"],"row_index":290,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrocarbon composition","parameters_en":[{"name":"Range","range":"(0,0002 – 99,0000) %mol"}],"search_en":"Gaseous fuels: natural gas Hydrocarbon composition Gas chromatography with flame ionization detection (GC-FID) Range PN-EN 27941:2015-12","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Gaseous fuels: natural gas","parameters_zh":[{"name":"范围","range":"(0,0002 – 99,0000) %mol"}],"search_zh":"气体燃料：天然气 烃类组成 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-EN 27941:2015-12","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"气体燃料：天然气","methodology_zh":"烃类组成"},{"_id":"6a836fb9af14b9c0e7b1ec3a","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: gaz ziemny","methodology":"Zawartość azotu","parameters":[{"name":"Zakres","range":"(0,05 – 5,00) %mol"}],"technique":"Metoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD)","techniques":["Metoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD)"],"computed":[],"activity":"Zawartość azotu\nZakres (0,05 – 5,00) %mol\nMetoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD)","reference":"ASTM D 1946-24","norm_bases":["ASTM D 1946-24"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: gaz ziemny Zawartość azotu\nZakres (0,05 – 5,00) %mol\nMetoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD) ASTM D 1946-24 Paliwa gazowe: gaz ziemny Zawartosc azotu\nZakres (0,05 – 5,00) %mol\nMetoda chromatografii gazowej z detekcja termokonduktometryczna (GC-TCD) ASTM D 1946-24","categories":["petro"],"row_index":291,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrogen content","parameters_en":[{"name":"Range","range":"(0,05 – 5,00) %mol"}],"search_en":"Gaseous fuels: natural gas Nitrogen content Gas chromatography with thermal conductivity detection (GC-TCD) Range ASTM D 1946-24","technique_en":"Gas chromatography with thermal conductivity detection (GC-TCD)","test_object_en":"Gaseous fuels: natural gas","methodology_zh":"氮含量","parameters_zh":[{"name":"范围","range":"(0,05 – 5,00) %mol"}],"search_zh":"气体燃料：天然气 氮含量 气相色谱-热导检测法（GC-TCD） 范围 ASTM D 1946-24","technique_zh":"气相色谱-热导检测法（GC-TCD）","test_object_zh":"气体燃料：天然气"},{"_id":"6a836fb9af14b9c0e7b1ec3b","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: gaz ziemny","methodology":"Zawartość ditlenku węgla","parameters":[{"name":"Zakres","range":"(0,0010 – 1,0000) %mol"}],"technique":"Metoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD)","techniques":["Metoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD)"],"computed":[],"activity":"Zawartość ditlenku węgla\nZakres (0,0010 – 1,0000) %mol\nMetoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD)","reference":"Metoda 048 pkt 1.1 wyd. 4 z dnia 27.12.2023","norm_bases":["Metoda 048 pkt 1.1 wyd. 4 z dnia 27.12.2023"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: gaz ziemny Zawartość ditlenku węgla\nZakres (0,0010 – 1,0000) %mol\nMetoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD) Metoda 048 pkt 1.1 wyd. 4 z dnia 27.12.2023 Paliwa gazowe: gaz ziemny Zawartosc ditlenku wegla\nZakres (0,0010 – 1,0000) %mol\nMetoda chromatografii gazowej z detekcja termokonduktometryczna (GC-TCD) Metoda 048 pkt 1.1 wyd. 4 z dnia 27.12.2023","categories":["petro"],"row_index":292,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Carbon dioxide content","parameters_en":[{"name":"Range","range":"(0,0010 – 1,0000) %mol"}],"search_en":"Gaseous fuels: natural gas Carbon dioxide content Gas chromatography with thermal conductivity detection (GC-TCD) Range Metoda 048 pkt 1.1 wyd. 4 z dnia 27.12.2023","technique_en":"Gas chromatography with thermal conductivity detection (GC-TCD)","test_object_en":"Gaseous fuels: natural gas","parameters_zh":[{"name":"范围","range":"(0,0010 – 1,0000) %mol"}],"search_zh":"气体燃料：天然气 气相色谱-热导检测法（GC-TCD） 范围 Metoda 048 pkt 1.1 wyd. 4 z dnia 27.12.2023","technique_zh":"气相色谱-热导检测法（GC-TCD）","test_object_zh":"气体燃料：天然气"},{"_id":"6a836fb9af14b9c0e7b1ec3c","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: gaz ziemny","methodology":"Gęstość (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Gęstość (z obliczeń)","reference":"PN-EN ISO 6976:2016-11","norm_bases":["PN-EN ISO 6976:2016-11"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: gaz ziemny Gęstość (z obliczeń) PN-EN ISO 6976:2016-11 Paliwa gazowe: gaz ziemny Gestosc (z obliczen) PN-EN ISO 6976:2016-11","categories":["petro"],"row_index":293,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Density (calculated)","search_en":"Gaseous fuels: natural gas Density (calculated) PN-EN ISO 6976:2016-11","test_object_en":"Gaseous fuels: natural gas","search_zh":"气体燃料：天然气 密度（由计算得出） PN-EN ISO 6976:2016-11","test_object_zh":"气体燃料：天然气","methodology_zh":"密度（由计算得出）"},{"_id":"6a836fb9af14b9c0e7b1ec3d","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: gaz ziemny","methodology":"Wartość opałowa (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wartość opałowa (z obliczeń)","reference":"PN-EN ISO 6976:2016-11","norm_bases":["PN-EN ISO 6976:2016-11"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: gaz ziemny Wartość opałowa (z obliczeń) PN-EN ISO 6976:2016-11 Paliwa gazowe: gaz ziemny Wartosc opalowa (z obliczen) PN-EN ISO 6976:2016-11","categories":["petro"],"row_index":294,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Net calorific value (calculated)","search_en":"Gaseous fuels: natural gas Net calorific value (calculated) PN-EN ISO 6976:2016-11","test_object_en":"Gaseous fuels: natural gas","methodology_zh":"低位发热量（计算值）","search_zh":"气体燃料：天然气 低位发热量（计算值） PN-EN ISO 6976:2016-11","test_object_zh":"气体燃料：天然气"},{"_id":"6a836fb9af14b9c0e7b1ec3e","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: gaz opałowy","methodology":"Skład węglowodorowy","parameters":[{"name":"Zakres","range":"(0,01 – 99,00) %mol"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Skład węglowodorowy\nZakres (0,01 – 99,00) %mol\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 27941:2015-12","norm_bases":["PN-EN 27941:2015-12"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: gaz opałowy Skład węglowodorowy\nZakres (0,01 – 99,00) %mol\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 27941:2015-12 Paliwa gazowe: gaz opalowy Sklad weglowodorowy\nZakres (0,01 – 99,00) %mol\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 27941:2015-12","categories":["petro"],"row_index":295,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrocarbon composition","parameters_en":[{"name":"Range","range":"(0,01 – 99,00) %mol"}],"search_en":"Gaseous fuels: fuel gas Hydrocarbon composition Gas chromatography with flame ionization detection (GC-FID) Range PN-EN 27941:2015-12","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Gaseous fuels: fuel gas","parameters_zh":[{"name":"范围","range":"(0,01 – 99,00) %mol"}],"search_zh":"气体燃料：燃料气 烃类组成 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-EN 27941:2015-12","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","methodology_zh":"烃类组成","test_object_zh":"气体燃料：燃料气"},{"_id":"6a836fb9af14b9c0e7b1ec3f","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: gaz opałowy","methodology":"Zawartość azotu","parameters":[{"name":"Zakres","range":"(0,05 – 10,00) %mol"}],"technique":"Metoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD)","techniques":["Metoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD)"],"computed":[],"activity":"Zawartość azotu\nZakres (0,05 – 10,00) %mol\nMetoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD)","reference":"ASTM D 1946-24","norm_bases":["ASTM D 1946-24"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: gaz opałowy Zawartość azotu\nZakres (0,05 – 10,00) %mol\nMetoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD) ASTM D 1946-24 Paliwa gazowe: gaz opalowy Zawartosc azotu\nZakres (0,05 – 10,00) %mol\nMetoda chromatografii gazowej z detekcja termokonduktometryczna (GC-TCD) ASTM D 1946-24","categories":["petro"],"row_index":296,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrogen content","parameters_en":[{"name":"Range","range":"(0,05 – 10,00) %mol"}],"search_en":"Gaseous fuels: fuel gas Nitrogen content Gas chromatography with thermal conductivity detection (GC-TCD) Range ASTM D 1946-24","technique_en":"Gas chromatography with thermal conductivity detection (GC-TCD)","test_object_en":"Gaseous fuels: fuel gas","methodology_zh":"氮含量","parameters_zh":[{"name":"范围","range":"(0,05 – 10,00) %mol"}],"search_zh":"气体燃料：燃料气 氮含量 气相色谱-热导检测法（GC-TCD） 范围 ASTM D 1946-24","technique_zh":"气相色谱-热导检测法（GC-TCD）","test_object_zh":"气体燃料：燃料气"},{"_id":"6a836fb9af14b9c0e7b1ec40","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: gaz opałowy","methodology":"Zawartość wodoru","parameters":[{"name":"Zakres","range":"(0,01 – 60,00) %mol"}],"technique":"Metoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD)","techniques":["Metoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD)"],"computed":[],"activity":"Zawartość wodoru\nZakres (0,01 – 60,00) %mol\nMetoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD)","reference":"ASTM D 1946-24","norm_bases":["ASTM D 1946-24"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: gaz opałowy Zawartość wodoru\nZakres (0,01 – 60,00) %mol\nMetoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD) ASTM D 1946-24 Paliwa gazowe: gaz opalowy Zawartosc wodoru\nZakres (0,01 – 60,00) %mol\nMetoda chromatografii gazowej z detekcja termokonduktometryczna (GC-TCD) ASTM D 1946-24","categories":["petro"],"row_index":297,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrogen content","parameters_en":[{"name":"Range","range":"(0,01 – 60,00) %mol"}],"search_en":"Gaseous fuels: fuel gas Hydrogen content Gas chromatography with thermal conductivity detection (GC-TCD) Range ASTM D 1946-24","technique_en":"Gas chromatography with thermal conductivity detection (GC-TCD)","test_object_en":"Gaseous fuels: fuel gas","parameters_zh":[{"name":"范围","range":"(0,01 – 60,00) %mol"}],"search_zh":"气体燃料：燃料气 氢含量 气相色谱-热导检测法（GC-TCD） 范围 ASTM D 1946-24","methodology_zh":"氢含量","technique_zh":"气相色谱-热导检测法（GC-TCD）","test_object_zh":"气体燃料：燃料气"},{"_id":"6a836fb9af14b9c0e7b1ec41","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: gaz opałowy","methodology":"Gęstość (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Gęstość (z obliczeń)","reference":"PN-EN ISO 6976:2016-11","norm_bases":["PN-EN ISO 6976:2016-11"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: gaz opałowy Gęstość (z obliczeń) PN-EN ISO 6976:2016-11 Paliwa gazowe: gaz opalowy Gestosc (z obliczen) PN-EN ISO 6976:2016-11","categories":["petro"],"row_index":298,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Density (calculated)","search_en":"Gaseous fuels: fuel gas Density (calculated) PN-EN ISO 6976:2016-11","test_object_en":"Gaseous fuels: fuel gas","methodology_zh":"密度（由计算得出）","search_zh":"气体燃料：燃料气 密度（由计算得出） PN-EN ISO 6976:2016-11","test_object_zh":"气体燃料：燃料气"},{"_id":"6a836fb9af14b9c0e7b1ec42","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: gaz opałowy","methodology":"Wartość opałowa (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wartość opałowa (z obliczeń)","reference":"PN-EN ISO 6976:2016-11","norm_bases":["PN-EN ISO 6976:2016-11"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: gaz opałowy Wartość opałowa (z obliczeń) PN-EN ISO 6976:2016-11 Paliwa gazowe: gaz opalowy Wartosc opalowa (z obliczen) PN-EN ISO 6976:2016-11","categories":["petro"],"row_index":299,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Net calorific value (calculated)","search_en":"Gaseous fuels: fuel gas Net calorific value (calculated) PN-EN ISO 6976:2016-11","test_object_en":"Gaseous fuels: fuel gas","methodology_zh":"低位发热量（计算值）","search_zh":"气体燃料：燃料气 低位发热量（计算值） PN-EN ISO 6976:2016-11","test_object_zh":"气体燃料：燃料气"},{"_id":"6a836fb9af14b9c0e7b1ec43","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość estrów metylowych kwasów tłuszczowych (FAME)","parameters":[{"name":"Suma estrów","range":"(90,0 – 100,0) %(m/m)"},{"name":"Zawartość estru metylowego kwasu linolenowego","range":"(1,0 – 15,0) % (m/m)"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość estrów metylowych kwasów tłuszczowych (FAME)\nZakres:\nSuma estrów (90,0 – 100,0) %(m/m)\nZawartość estru metylowego kwasu linolenowego (1,0 – 15,0) % (m/m)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 14103:2020-06","norm_bases":["PN-EN 14103:2020-06"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Zawartość estrów metylowych kwasów tłuszczowych (FAME)\nZakres:\nSuma estrów (90,0 – 100,0) %(m/m)\nZawartość estru metylowego kwasu linolenowego (1,0 – 15,0) % (m/m)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 14103:2020-06 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Zawartosc estrow metylowych kwasow tluszczowych (FAME)\nZakres:\nSuma estrow (90,0 – 100,0) %(m/m)\nZawartosc estru metylowego kwasu linolenowego (1,0 – 15,0) % (m/m)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 14103:2020-06","categories":["petro"],"row_index":300,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fatty acid methyl esters (FAME) content","parameters_en":[{"name":"Sum of esters","range":"(90,0 – 100,0) %(m/m)"},{"name":"Linolenic acid methyl ester content","range":"(1,0 – 15,0) % (m/m)"}],"search_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME) Fatty acid methyl esters (FAME) content Gas chromatography with flame ionization detection (GC-FID) Sum of esters Linolenic acid methyl ester content PN-EN 14103:2020-06","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME)","search_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME） 脂肪酸甲酯（FAME）含量 气相色谱-氢火焰离子化检测法（GC-FID） PN-EN 14103:2020-06","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME）","methodology_zh":"脂肪酸甲酯（FAME）含量"},{"_id":"6a836fb9af14b9c0e7b1ec44","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość sumy wielonienasyconych estrów metylowych kwasów tłuszczowych (≥4 wiązania podwójne) (PUFA)","parameters":[{"name":"Zakres","range":"(0,30 – 3,00) %(m/m)"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość sumy wielonienasyconych estrów metylowych kwasów tłuszczowych (≥4 wiązania podwójne) (PUFA)\nZakres (0,30 – 3,00) %(m/m)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 15779+A1:2013-12","norm_bases":["PN-EN 15779+A1:2013-12"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Zawartość sumy wielonienasyconych estrów metylowych kwasów tłuszczowych (≥4 wiązania podwójne) (PUFA)\nZakres (0,30 – 3,00) %(m/m)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 15779+A1:2013-12 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Zawartosc sumy wielonienasyconych estrow metylowych kwasow tluszczowych (≥4 wiazania podwojne) (PUFA)\nZakres (0,30 – 3,00) %(m/m)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 15779+A1:2013-12","categories":["petro"],"row_index":301,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of the sum of polyunsaturated fatty acid methyl esters (≥4 double bonds) (PUFA)","parameters_en":[{"name":"Range","range":"(0,30 – 3,00) %(m/m)"}],"search_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME) Content of the sum of polyunsaturated fatty acid methyl esters (≥4 double bonds) (PUFA) Gas chromatography with flame ionization detection (GC-FID) Range PN-EN 15779+A1:2013-12","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME)","parameters_zh":[{"name":"范围","range":"(0,30 – 3,00) %(m/m)"}],"search_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME） 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-EN 15779+A1:2013-12","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME）"},{"_id":"6a836fb9af14b9c0e7b1ec45","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość wolnego i ogólnego glicerolu oraz mono-, di- i triacylogliceroli","parameters":[{"name":"Monoacyloglicerole"},{"name":"Zakres","range":"(0,05 – 1,25) % (m/m)"},{"name":"Diacyloglicerole","range":"(0,05 – 0,50) %(m/m)"},{"name":"Triacyloglicerole","range":"(0,05 – 0,50) %(m/m)"},{"name":"Wolny glicerol","range":"(0,001 – 0,050) %(m/m)"},{"name":"Ogólny glicerol (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość wolnego i ogólnego glicerolu oraz mono-, di- i triacylogliceroli\nZakres:\nMonoacyloglicerole\nZakres (0,05 – 1,25) % (m/m)\nDiacyloglicerole (0,05 – 0,50) %(m/m)\nTriacyloglicerole (0,05 – 0,50) %(m/m)\nWolny glicerol (0,001 – 0,050) %(m/m)\nOgólny glicerol (z obliczeń)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 14105:2025-04","norm_bases":["PN-EN 14105:2025-04"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Zawartość wolnego i ogólnego glicerolu oraz mono-, di- i triacylogliceroli\nZakres:\nMonoacyloglicerole\nZakres (0,05 – 1,25) % (m/m)\nDiacyloglicerole (0,05 – 0,50) %(m/m)\nTriacyloglicerole (0,05 – 0,50) %(m/m)\nWolny glicerol (0,001 – 0,050) %(m/m)\nOgólny glicerol (z obliczeń)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 14105:2025-04 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Zawartosc wolnego i ogolnego glicerolu oraz mono-, di- i triacylogliceroli\nZakres:\nMonoacyloglicerole\nZakres (0,05 – 1,25) % (m/m)\nDiacyloglicerole (0,05 – 0,50) %(m/m)\nTriacyloglicerole (0,05 – 0,50) %(m/m)\nWolny glicerol (0,001 – 0,050) %(m/m)\nOgolny glicerol (z obliczen)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 14105:2025-04","categories":["petro"],"row_index":302,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of free and total glycerol and of mono-, di- and triacylglycerols","parameters_en":[{"name":"Monoacylglycerols"},{"name":"Range","range":"(0,05 – 1,25) % (m/m)"},{"name":"Diacylglycerols","range":"(0,05 – 0,50) %(m/m)"},{"name":"Triacylglycerols","range":"(0,05 – 0,50) %(m/m)"},{"name":"Free glycerol","range":"(0,001 – 0,050) %(m/m)"},{"name":"Total glycerol (calculated)"}],"search_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME) Content of free and total glycerol and of mono-, di- and triacylglycerols Gas chromatography with flame ionization detection (GC-FID) Monoacylglycerols Range Diacylglycerols Triacylglycerols Free glycerol Total glycerol (calculated) PN-EN 14105:2025-04","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME)","parameters_zh":[{"name":"Monoacyloglicerole"},{"name":"范围","range":"(0,05 – 1,25) % (m/m)"},{"name":"Diacyloglicerole","range":"(0,05 – 0,50) %(m/m)"},{"name":"Triacyloglicerole","range":"(0,05 – 0,50) %(m/m)"},{"name":"Wolny glicerol","range":"(0,001 – 0,050) %(m/m)"},{"name":"总甘油（由计算得出）"}],"search_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME） 气相色谱-氢火焰离子化检测法（GC-FID） 范围 总甘油（由计算得出） PN-EN 14105:2025-04","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME）"},{"_id":"6a836fb9af14b9c0e7b1ec46","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: bioetanol","methodology":"Zawartość wyższych alkoholi, metanolu i innych zanieczyszczeń","parameters":[{"name":"metanol","range":"(0,010 – 3,000) %(m/m)"},{"name":"Wyższe alkohole","range":"(C3-C5)"},{"name":"Zakres","range":"(0,010 – 2,500) %(m/m)"},{"name":"etanol wraz z wyższymi alkoholami – powyżej 95,000 %(m/m) inne zanieczyszczenia","range":"(0,010 – 2,000) %(m/m)"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość wyższych alkoholi, metanolu i innych zanieczyszczeń\nZakres:\nmetanol (0,010 – 3,000) %(m/m)\nWyższe alkohole (C3-C5)\nZakres (0,010 – 2,500) %(m/m)\netanol wraz z wyższymi alkoholami – powyżej 95,000 %(m/m) inne zanieczyszczenia (0,010 – 2,000) %(m/m)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 15721:2013-10 Procedura A","norm_bases":["PN-EN 15721:2013-10 Procedura A"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: bioetanol Zawartość wyższych alkoholi, metanolu i innych zanieczyszczeń\nZakres:\nmetanol (0,010 – 3,000) %(m/m)\nWyższe alkohole (C3-C5)\nZakres (0,010 – 2,500) %(m/m)\netanol wraz z wyższymi alkoholami – powyżej 95,000 %(m/m) inne zanieczyszczenia (0,010 – 2,000) %(m/m)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 15721:2013-10 Procedura A Paliwa ciekle: biopaliwa ciekle: bioetanol Zawartosc wyzszych alkoholi, metanolu i innych zanieczyszczen\nZakres:\nmetanol (0,010 – 3,000) %(m/m)\nWyzsze alkohole (C3-C5)\nZakres (0,010 – 2,500) %(m/m)\netanol wraz z wyzszymi alkoholami – powyzej 95,000 %(m/m) inne zanieczyszczenia (0,010 – 2,000) %(m/m)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 15721:2013-10 Procedura A","categories":["petro"],"row_index":303,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of higher alcohols, methanol and other impurities","parameters_en":[{"name":"methanol","range":"(0,010 – 3,000) %(m/m)"},{"name":"Higher alcohols","range":"(C3-C5)"},{"name":"Range","range":"(0,010 – 2,500) %(m/m)"},{"name":"ethanol together with higher alcohols – above 95,000 %(m/m) other impurities","range":"(0,010 – 2,000) %(m/m)"}],"search_en":"Liquid fuels: liquid biofuels: bioethanol Content of higher alcohols, methanol and other impurities Gas chromatography with flame ionization detection (GC-FID) methanol Higher alcohols Range ethanol together with higher alcohols – above 95,000 %(m/m) other impurities PN-EN 15721:2013-10 Procedura A","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Liquid fuels: liquid biofuels: bioethanol","parameters_zh":[{"name":"甲醇","range":"(0,010 – 3,000) %(m/m)"},{"name":"Wyższe alkohole","range":"(C3-C5)"},{"name":"范围","range":"(0,010 – 2,500) %(m/m)"},{"name":"etanol wraz z wyższymi alkoholami – powyżej 95,000 %(m/m) inne zanieczyszczenia","range":"(0,010 – 2,000) %(m/m)"}],"search_zh":"液体燃料：液体生物燃料：生物乙醇 气相色谱-氢火焰离子化检测法（GC-FID） 甲醇 范围 PN-EN 15721:2013-10 Procedura A","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"液体燃料：液体生物燃料：生物乙醇"},{"_id":"6a836fb9af14b9c0e7b1ec47","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie lotnych węglowodorów aromatycznych","parameters":[{"name":"benzen","range":"(3,0 – 14000) μg/l"},{"name":"toluen","range":"(3,0 – 14000) μg/l"},{"name":"etylobenzen","range":"(3,0 – 14000) μg/l"},{"name":"(m+p)-ksylen","range":"(3,0 – 27000) μg/l"},{"name":"o-ksylen","range":"(3,0 – 14000) μg/l"},{"name":"kumen","range":"(3,0 – 14000) μg/l"},{"name":"Suma ksylenów, suma BTEX (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID)","techniques":["Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID)"],"computed":[],"activity":"Stężenie lotnych węglowodorów aromatycznych\nZakres:\nbenzen (3,0 – 14000) μg/l\ntoluen (3,0 – 14000) μg/l\netylobenzen (3,0 – 14000) μg/l\n(m+p)-ksylen (3,0 – 27000) μg/l\no-ksylen (3,0 – 14000) μg/l\nkumen (3,0 – 14000) μg/l\nSuma ksylenów, suma BTEX (z obliczeń)\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID)","reference":"PN-ISO 11423-1:2002","norm_bases":["PN-ISO 11423-1:2002"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie lotnych węglowodorów aromatycznych\nZakres:\nbenzen (3,0 – 14000) μg/l\ntoluen (3,0 – 14000) μg/l\netylobenzen (3,0 – 14000) μg/l\n(m+p)-ksylen (3,0 – 27000) μg/l\no-ksylen (3,0 – 14000) μg/l\nkumen (3,0 – 14000) μg/l\nSuma ksylenów, suma BTEX (z obliczeń)\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID) PN-ISO 11423-1:2002 Woda, scieki Stezenie lotnych weglowodorow aromatycznych\nZakres:\nbenzen (3,0 – 14000) μg/l\ntoluen (3,0 – 14000) μg/l\netylobenzen (3,0 – 14000) μg/l\n(m+p)-ksylen (3,0 – 27000) μg/l\no-ksylen (3,0 – 14000) μg/l\nkumen (3,0 – 14000) μg/l\nSuma ksylenow, suma BTEX (z obliczen)\nMetoda chromatografii gazowej z analiza fazy nadpowierzchniowej i detekcja plomieniowo-jonizacyjna (HS-GC-FID) PN-ISO 11423-1:2002","categories":["water"],"row_index":304,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of volatile aromatic hydrocarbons","parameters_en":[{"name":"benzene","range":"(3,0 – 14000) μg/l"},{"name":"toluene","range":"(3,0 – 14000) μg/l"},{"name":"ethylbenzene","range":"(3,0 – 14000) μg/l"},{"name":"(m+p)-xylene","range":"(3,0 – 27000) μg/l"},{"name":"o-xylene","range":"(3,0 – 14000) μg/l"},{"name":"cumene","range":"(3,0 – 14000) μg/l"},{"name":"Suma ksylenów, suma BTEX (z obliczeń)"}],"search_en":"Water, wastewater Concentration of volatile aromatic hydrocarbons Headspace gas chromatography with flame ionization detection (HS-GC-FID) benzene toluene ethylbenzene (m+p)-xylene o-xylene cumene PN-ISO 11423-1:2002","technique_en":"Headspace gas chromatography with flame ionization detection (HS-GC-FID)","test_object_en":"Water, wastewater","search_zh":"水、废水 挥发性芳香烃浓度 顶空气相色谱-火焰离子化检测法（HS-GC-FID） 苯 甲苯 乙苯 (间+对)-二甲苯 邻二甲苯 异丙苯 PN-ISO 11423-1:2002","test_object_zh":"水、废水","parameters_zh":[{"name":"苯","range":"(3,0 – 14000) μg/l"},{"name":"甲苯","range":"(3,0 – 14000) μg/l"},{"name":"乙苯","range":"(3,0 – 14000) μg/l"},{"name":"(间+对)-二甲苯","range":"(3,0 – 27000) μg/l"},{"name":"邻二甲苯","range":"(3,0 – 14000) μg/l"},{"name":"异丙苯","range":"(3,0 – 14000) μg/l"},{"name":"Suma ksylenów, suma BTEX (z obliczeń)"}],"technique_zh":"顶空气相色谱-火焰离子化检测法（HS-GC-FID）","methodology_zh":"挥发性芳香烃浓度"},{"_id":"6a836fb9af14b9c0e7b1ec48","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"Indeks oleju mineralnego","parameters":[{"name":"Zakres","range":"(0,10 – 100) mg/l"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Indeks oleju mineralnego\nZakres (0,10 – 100) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN ISO 9377-2:2003","norm_bases":["PN-EN ISO 9377-2:2003"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Indeks oleju mineralnego\nZakres (0,10 – 100) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN ISO 9377-2:2003 Scieki Indeks oleju mineralnego\nZakres (0,10 – 100) mg/l\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN ISO 9377-2:2003","categories":["water","petro"],"row_index":305,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mineral oil index","parameters_en":[{"name":"Range","range":"(0,10 – 100) mg/l"}],"search_en":"Wastewater Mineral oil index Gas chromatography with flame ionization detection (GC-FID) Range PN-EN ISO 9377-2:2003","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(0,10 – 100) mg/l"}],"search_zh":"污水 矿物油指数 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-EN ISO 9377-2:2003","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"污水","methodology_zh":"矿物油指数"},{"_id":"6a836fb9af14b9c0e7b1ec49","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy – próbki powietrza pobrane na filtry i rurki z sorbentem","methodology":"Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA)","parameters":[{"name":"antracen (0,005 – 0,500) μg w próbce benzo(a)antracen"},{"name":"Zakres","range":"(0,010 – 1,000) μg w próbce"},{"name":"chryzen (0,020 – 2,000) μg w próbce benzo(b)fluoranten (0,010 – 1,000) μg w próbce benzo(k)fluoranten (0,010 – 1,000) μg w próbce benzo(a)piren (0,020 – 2,000) μg w próbce dibenzo(ah)antracen (0,040 – 4,000) μg w próbce benzo(ghi)perylen (0,020 – 2,000) μg w próbce indeno","range":"(123cd)piren"},{"name":"(0,020 – 0,100) μg w próbce"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA)\nZakres:\nantracen (0,005 – 0,500) μg w próbce benzo(a)antracen\nZakres (0,010 – 1,000) μg w próbce\nchryzen (0,020 – 2,000) μg w próbce benzo(b)fluoranten (0,010 – 1,000) μg w próbce benzo(k)fluoranten (0,010 – 1,000) μg w próbce benzo(a)piren (0,020 – 2,000) μg w próbce dibenzo(ah)antracen (0,040 – 4,000) μg w próbce benzo(ghi)perylen (0,020 – 2,000) μg w próbce indeno (123cd)piren\n(0,020 – 0,100) μg w próbce\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"PN-Z-04240-5:2006","norm_bases":["PN-Z-04240-5:2006"],"lab_section":"Pracownia Chromatografii PP3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – próbki powietrza pobrane na filtry i rurki z sorbentem Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA)\nZakres:\nantracen (0,005 – 0,500) μg w próbce benzo(a)antracen\nZakres (0,010 – 1,000) μg w próbce\nchryzen (0,020 – 2,000) μg w próbce benzo(b)fluoranten (0,010 – 1,000) μg w próbce benzo(k)fluoranten (0,010 – 1,000) μg w próbce benzo(a)piren (0,020 – 2,000) μg w próbce dibenzo(ah)antracen (0,040 – 4,000) μg w próbce benzo(ghi)perylen (0,020 – 2,000) μg w próbce indeno (123cd)piren\n(0,020 – 0,100) μg w próbce\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) PN-Z-04240-5:2006 Srodowisko pracy – probki powietrza pobrane na filtry i rurki z sorbentem Zawartosc wielopierscieniowych weglowodorow aromatycznych (WWA)\nZakres:\nantracen (0,005 – 0,500) μg w probce benzo(a)antracen\nZakres (0,010 – 1,000) μg w probce\nchryzen (0,020 – 2,000) μg w probce benzo(b)fluoranten (0,010 – 1,000) μg w probce benzo(k)fluoranten (0,010 – 1,000) μg w probce benzo(a)piren (0,020 – 2,000) μg w probce dibenzo(ah)antracen (0,040 – 4,000) μg w probce benzo(ghi)perylen (0,020 – 2,000) μg w probce indeno (123cd)piren\n(0,020 – 0,100) μg w probce\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) PN-Z-04240-5:2006","categories":["environment"],"row_index":306,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Polycyclic aromatic hydrocarbons (PAH) content","parameters_en":[{"name":"anthracene (0,005 – 0,500) μg in the sample benzo(a)anthracene"},{"name":"Range","range":"(0,010 – 1,000) μg w próbce"},{"name":"chrysene (0,020 – 2,000) μg in the sample benzo(b)fluoranthene (0,010 – 1,000) μg in the sample benzo(k)fluoranthene (0,010 – 1,000) μg in the sample benzo(a)pyrene (0,020 – 2,000) μg in the sample dibenzo(ah)anthracene (0,040 – 4,000) μg in the sample benzo(ghi)perylene (0,020 – 2,000) μg in the sample indeno","range":"(123cd)piren"},{"name":"(0,020 – 0,100) μg in the sample"}],"search_en":"Workplace environment – air samples collected on filters and sorbent tubes Polycyclic aromatic hydrocarbons (PAH) content High-performance liquid chromatography with fluorescence detection (HPLC-FLD) anthracene (0,005 – 0,500) μg in the sample benzo(a)anthracene Range chrysene (0,020 – 2,000) μg in the sample benzo(b)fluoranthene (0,010 – 1,000) μg in the sample benzo(k)fluoranthene (0,010 – 1,000) μg in the sample benzo(a)pyrene (0,020 – 2,000) μg in the sample dibenzo(ah)anthracene (0,040 – 4,000) μg in the sample benzo(ghi)perylene (0,020 – 2,000) μg in the sample indeno (0,020 – 0,100) μg in the sample PN-Z-04240-5:2006","technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD)","test_object_en":"Workplace environment – air samples collected on filters and sorbent tubes","parameters_zh":[{"name":"antracen (0,005 – 0,500) μg w próbce benzo(a)antracen"},{"name":"范围","range":"(0,010 – 1,000) μg w próbce"},{"name":"chryzen (0,020 – 2,000) μg w próbce benzo(b)fluoranten (0,010 – 1,000) μg w próbce benzo(k)fluoranten (0,010 – 1,000) μg w próbce benzo(a)piren (0,020 – 2,000) μg w próbce dibenzo(ah)antracen (0,040 – 4,000) μg w próbce benzo(ghi)perylen (0,020 – 2,000) μg w próbce indeno","range":"(123cd)piren"},{"name":"(0,020 – 0,100) μg w próbce"}],"search_zh":"多环芳烃（PAHs）含量 高效液相色谱-荧光检测法（HPLC-FLD） 范围 PN-Z-04240-5:2006","technique_zh":"高效液相色谱-荧光检测法（HPLC-FLD）","methodology_zh":"多环芳烃（PAHs）含量"},{"_id":"6a836fb9af14b9c0e7b1ec4a","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, benzyna, olej opałowy lekki, olej opałowy ciężki, paliwo do turbinowych silników lotniczych, biopaliwo ciekłe: estry metylowe kwasów tłuszczowych (FAME), bioetanol","methodology":"Pobieranie próbek ze zbiorników do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek ze zbiorników do badań chemicznych i fizycznych","reference":"PN-EN ISO 3170:2025-12 z wyłączeniem 8.3.1.5, 8.3.1.8, 8.3.2, 8.7,8.8, 10.6, 10.7","norm_bases":["PN-EN ISO 3170:2025-12 z wyłączeniem 8.3.1.5, 8.3.1.8, 8.3.2, 8.7,8.8, 10.6, 10.7"],"lab_section":"Zespół Logistyki Płock LL/P","lab_address":null,"regulatory_area":"Badania wykonywane poza siedzibą laboratorium","flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, benzyna, olej opałowy lekki, olej opałowy ciężki, paliwo do turbinowych silników lotniczych, biopaliwo ciekłe: estry metylowe kwasów tłuszczowych (FAME), bioetanol Pobieranie próbek ze zbiorników do badań chemicznych i fizycznych PN-EN ISO 3170:2025-12 z wyłączeniem 8.3.1.5, 8.3.1.8, 8.3.2, 8.7,8.8, 10.6, 10.7 Paliwa ciekle: olej napedowy, benzyna, olej opalowy lekki, olej opalowy ciezki, paliwo do turbinowych silnikow lotniczych, biopaliwo ciekle: estry metylowe kwasow tluszczowych (FAME), bioetanol Pobieranie probek ze zbiornikow do badan chemicznych i fizycznych PN-EN ISO 3170:2025-12 z wylaczeniem 8.3.1.5, 8.3.1.8, 8.3.2, 8.7,8.8, 10.6, 10.7","categories":["petro"],"row_index":307,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling from tanks for chemical and physical testing","search_en":"Sampling from tanks for chemical and physical testing PN-EN ISO 3170:2025-12 z wyłączeniem 8.3.1.5, 8.3.1.8, 8.3.2, 8.7,8.8, 10.6, 10.7","methodology_zh":"自储罐采集化学和物理检测样品","search_zh":"自储罐采集化学和物理检测样品 PN-EN ISO 3170:2025-12 z wyłączeniem 8.3.1.5, 8.3.1.8, 8.3.2, 8.7,8.8, 10.6, 10.7"},{"_id":"6a836fb9af14b9c0e7b1ec4b","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, benzyna","methodology":"Pobieranie próbek z dystrybutora do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek z dystrybutora do badań chemicznych i fizycznych","reference":"PN-EN 14275:2013-06","norm_bases":["PN-EN 14275:2013-06"],"lab_section":"Zespół Logistyki Płock LL/P","lab_address":null,"regulatory_area":"Badania wykonywane poza siedzibą laboratorium","flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, benzyna Pobieranie próbek z dystrybutora do badań chemicznych i fizycznych PN-EN 14275:2013-06 Paliwa ciekle: olej napedowy, benzyna Pobieranie probek z dystrybutora do badan chemicznych i fizycznych PN-EN 14275:2013-06","categories":["petro"],"row_index":308,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling from a dispenser for chemical and physical testing","search_en":"Liquid fuels: diesel fuel, petrol Sampling from a dispenser for chemical and physical testing PN-EN 14275:2013-06","test_object_en":"Liquid fuels: diesel fuel, petrol"},{"_id":"6a836fb9af14b9c0e7b1ec4c","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-EN ISO 4257:2004 ZN/MG/CN-18:2007","norm_bases":["PN-EN ISO 4257:2004 ZN/MG/CN-18:2007"],"lab_section":"Zespół Logistyki Płock LL/P","lab_address":null,"regulatory_area":"Badania wykonywane poza siedzibą laboratorium","flexible":false,"search_text":"Paliwa gazowe: skroplone gazy węglowodorowe, LPG Pobieranie próbek do badań chemicznych i fizycznych PN-EN ISO 4257:2004 ZN/MG/CN-18:2007 Paliwa gazowe: skroplone gazy weglowodorowe, LPG Pobieranie probek do badan chemicznych i fizycznych PN-EN ISO 4257:2004 ZN/MG/CN-18:2007","categories":["petro"],"row_index":309,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Gaseous fuels: liquefied petroleum gases, LPG Sampling for chemical and physical testing PN-EN ISO 4257:2004 ZN/MG/CN-18:2007","test_object_en":"Gaseous fuels: liquefied petroleum gases, LPG","methodology_zh":"化学与物理检测用样品采集","search_zh":"气体燃料：液化石油气（LPG） 化学与物理检测用样品采集 PN-EN ISO 4257:2004 ZN/MG/CN-18:2007","test_object_zh":"气体燃料：液化石油气（LPG）"},{"_id":"6a836fb9af14b9c0e7b1ec4d","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[{"name":"Temperatura pobranej próbki ścieków"},{"name":"Zakres","range":"(2,0 – 50,0) °C"}],"technique":"Metoda manualna","techniques":["Metoda manualna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura pobranej próbki ścieków\nZakres (2,0 – 50,0) °C\nMetoda manualna","reference":"PN-ISO 5667-10:2021-11 Metoda nr 111 Wydanie 5 z dnia 01.07.2020","norm_bases":["PN-ISO 5667-10:2021-11 Metoda nr 111 Wydanie 5 z dnia 01.07.2020"],"lab_section":"Zespół Logistyki Płock LL/P","lab_address":null,"regulatory_area":"Badania wykonywane poza siedzibą laboratorium","flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura pobranej próbki ścieków\nZakres (2,0 – 50,0) °C\nMetoda manualna PN-ISO 5667-10:2021-11 Metoda nr 111 Wydanie 5 z dnia 01.07.2020 Scieki Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nTemperatura pobranej probki sciekow\nZakres (2,0 – 50,0) °C\nMetoda manualna PN-ISO 5667-10:2021-11 Metoda nr 111 Wydanie 5 z dnia 01.07.2020","categories":["water"],"row_index":310,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","parameters_en":[{"name":"Temperature of the collected wastewater sample"},{"name":"Range","range":"(2,0 – 50,0) °C"}],"search_en":"Wastewater Sampling for chemical and physical testing Manual method Temperature of the collected wastewater sample Range PN-ISO 5667-10:2021-11 Metoda nr 111 Wydanie 5 z dnia 01.07.2020","technique_en":"Manual method","test_object_en":"Wastewater","methodology_zh":"化学与物理检测用样品采集","parameters_zh":[{"name":"所采废水样品的温度"},{"name":"范围","range":"(2,0 – 50,0) °C"}],"search_zh":"污水 化学与物理检测用样品采集 手工法 所采废水样品的温度 范围 PN-ISO 5667-10:2021-11 Metoda nr 111 Wydanie 5 z dnia 01.07.2020","test_object_zh":"污水","technique_zh":"手工法"},{"_id":"6a836fb9af14b9c0e7b1ec4e","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Zespół Logistyki Płock LL/P","lab_address":null,"regulatory_area":"Badania wykonywane poza siedzibą laboratorium","flexible":false,"search_text":"Ścieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Scieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":311,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"search_en":"Wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Wastewater","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"污水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"污水"},{"_id":"6a836fb9af14b9c0e7b1ec4f","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: wodór (automotive)","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[{"name":"ze zbiorników"},{"name":"ze stacji tankowania"},{"name":"z rurociągów na instalacji"}],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nze zbiorników\nze stacji tankowania\nz rurociągów na instalacji","reference":"ASTM D 7606-24a | ISO 21087:2019-06 p. 8 | ISO 19880-1:2020-03 załącznik K p. K1, K2, K3 | ISO 19880-09:2024 z wyłączeniem załącznika A, C, D, E, F","norm_bases":["ASTM D 7606-24a","ISO 21087:2019-06 p. 8","ISO 19880-1:2020-03 załącznik K p. K1, K2, K3","ISO 19880-09:2024 z wyłączeniem załącznika A, C, D, E, F"],"lab_section":"Zespół Logistyki Płock LL/P","lab_address":null,"regulatory_area":"Badania wykonywane poza siedzibą laboratorium","flexible":false,"search_text":"Paliwa gazowe: wodór (automotive) Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nze zbiorników\nze stacji tankowania\nz rurociągów na instalacji ASTM D 7606-24a | ISO 21087:2019-06 p. 8 | ISO 19880-1:2020-03 załącznik K p. K1, K2, K3 | ISO 19880-09:2024 z wyłączeniem załącznika A, C, D, E, F Paliwa gazowe: wodor (automotive) Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nze zbiornikow\nze stacji tankowania\nz rurociagow na instalacji ASTM D 7606-24a | ISO 21087:2019-06 p. 8 | ISO 19880-1:2020-03 zalacznik K p. K1, K2, K3 | ISO 19880-09:2024 z wylaczeniem zalacznika A, C, D, E, F","categories":["petro","automotive"],"row_index":312,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","parameters_en":[{"name":"from tanks"},{"name":"from the refuelling station"},{"name":"from pipelines in the installation"}],"search_en":"Gaseous fuels: hydrogen (automotive) Sampling for chemical and physical testing from tanks from the refuelling station from pipelines in the installation ASTM D 7606-24a | ISO 21087:2019-06 p. 8 | ISO 19880-1:2020-03 załącznik K p. K1, K2, K3 | ISO 19880-09:2024 z wyłączeniem załącznika A, C, D, E, F","test_object_en":"Gaseous fuels: hydrogen (automotive)","methodology_zh":"化学与物理检测用样品采集","search_zh":"气体燃料：氢（车用） 化学与物理检测用样品采集 来自储罐 来自加气站 ASTM D 7606-24a | ISO 21087:2019-06 p. 8 | ISO 19880-1:2020-03 załącznik K p. K1, K2, K3 | ISO 19880-09:2024 z wyłączeniem załącznika A, C, D, E, F","test_object_zh":"气体燃料：氢（车用）","parameters_zh":[{"name":"来自储罐"},{"name":"来自加气站"},{"name":"z rurociągów na instalacji"}]},{"_id":"6a836fb9af14b9c0e7b1ec50","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: wodór (automotive)","methodology":"Pobieranie próbek do zawartości cząstek stałych","parameters":[{"name":"ze zbiorników"},{"name":"ze stacji tankowania"},{"name":"z rurociągów"}],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do zawartości cząstek stałych\nZakres:\nze zbiorników\nze stacji tankowania\nz rurociągów","reference":"ASTM D 7650-21 z wyłączeniem 7.9 | ISO 21087:2019-06 p. 8 | ISO 19880-1:2020-03 załącznik K p. K1, K2, K7 z wyłączeniem p. K.7.1 | ISO 19880-9:2024-07 z wyłączeniem załącznika A, B, C, E, F","norm_bases":["ASTM D 7650-21 z wyłączeniem 7.9","ISO 21087:2019-06 p. 8","ISO 19880-1:2020-03 załącznik K p. K1, K2, K7 z wyłączeniem p. K.7.1","ISO 19880-9:2024-07 z wyłączeniem załącznika A, B, C, E, F"],"lab_section":"Zespół Logistyki Płock LL/P","lab_address":null,"regulatory_area":"Badania wykonywane poza siedzibą laboratorium","flexible":false,"search_text":"Paliwa gazowe: wodór (automotive) Pobieranie próbek do zawartości cząstek stałych\nZakres:\nze zbiorników\nze stacji tankowania\nz rurociągów ASTM D 7650-21 z wyłączeniem 7.9 | ISO 21087:2019-06 p. 8 | ISO 19880-1:2020-03 załącznik K p. K1, K2, K7 z wyłączeniem p. K.7.1 | ISO 19880-9:2024-07 z wyłączeniem załącznika A, B, C, E, F Paliwa gazowe: wodor (automotive) Pobieranie probek do zawartosci czastek stalych\nZakres:\nze zbiornikow\nze stacji tankowania\nz rurociagow ASTM D 7650-21 z wylaczeniem 7.9 | ISO 21087:2019-06 p. 8 | ISO 19880-1:2020-03 zalacznik K p. K1, K2, K7 z wylaczeniem p. K.7.1 | ISO 19880-9:2024-07 z wylaczeniem zalacznika A, B, C, E, F","categories":["petro","automotive"],"row_index":313,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for particulate matter content","parameters_en":[{"name":"from tanks"},{"name":"from the refuelling station"},{"name":"from pipelines"}],"search_en":"Gaseous fuels: hydrogen (automotive) Sampling for particulate matter content from tanks from the refuelling station from pipelines ASTM D 7650-21 z wyłączeniem 7.9 | ISO 21087:2019-06 p. 8 | ISO 19880-1:2020-03 załącznik K p. K1, K2, K7 z wyłączeniem p. K.7.1 | ISO 19880-9:2024-07 z wyłączeniem załącznika A, B, C, E, F","test_object_en":"Gaseous fuels: hydrogen (automotive)","search_zh":"气体燃料：氢（车用） 来自储罐 来自加气站 ASTM D 7650-21 z wyłączeniem 7.9 | ISO 21087:2019-06 p. 8 | ISO 19880-1:2020-03 załącznik K p. K1, K2, K7 z wyłączeniem p. K.7.1 | ISO 19880-9:2024-07 z wyłączeniem załącznika A, B, C, E, F","test_object_zh":"气体燃料：氢（车用）","parameters_zh":[{"name":"来自储罐"},{"name":"来自加气站"},{"name":"z rurociągów"}]},{"_id":"6a836fb9af14b9c0e7b1ec51","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[{"name":"Temperatura pobranej próbki Zakres:","range":"(2,0 – 50,0) °C"}],"technique":"Metoda manualna","techniques":["Metoda manualna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nTemperatura pobranej próbki Zakres: (2,0 – 50,0) °C\nMetoda manualna","reference":"PN-ISO 5667-10:2021-11 Metoda nr 111 Wydanie 5 z dnia 01.07.2020","norm_bases":["PN-ISO 5667-10:2021-11 Metoda nr 111 Wydanie 5 z dnia 01.07.2020"],"lab_section":"Zespół Logistyki Włocławek LL/W","lab_address":null,"regulatory_area":"Badania wykonywane poza siedzibą laboratorium","flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nTemperatura pobranej próbki Zakres: (2,0 – 50,0) °C\nMetoda manualna PN-ISO 5667-10:2021-11 Metoda nr 111 Wydanie 5 z dnia 01.07.2020 Scieki Pobieranie probek do badan chemicznych i fizycznych\nTemperatura pobranej probki Zakres: (2,0 – 50,0) °C\nMetoda manualna PN-ISO 5667-10:2021-11 Metoda nr 111 Wydanie 5 z dnia 01.07.2020","categories":["water"],"row_index":314,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","parameters_en":[{"name":"Temperature of the collected sample Range:","range":"(2,0 – 50,0) °C"}],"search_en":"Wastewater Sampling for chemical and physical testing Manual method Temperature of the collected sample Range: PN-ISO 5667-10:2021-11 Metoda nr 111 Wydanie 5 z dnia 01.07.2020","technique_en":"Manual method","test_object_en":"Wastewater","methodology_zh":"化学与物理检测用样品采集","search_zh":"污水 化学与物理检测用样品采集 手工法 PN-ISO 5667-10:2021-11 Metoda nr 111 Wydanie 5 z dnia 01.07.2020","test_object_zh":"污水","technique_zh":"手工法"},{"_id":"6a836fb9af14b9c0e7b1ec52","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":"Metoda automatyczna","techniques":["Metoda automatyczna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda automatyczna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":"Zespół Logistyki Włocławek LL/W","lab_address":null,"regulatory_area":"Badania wykonywane poza siedzibą laboratorium","flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nMetoda automatyczna PN-ISO 5667-10:2021-11 Scieki Pobieranie probek do badan chemicznych i fizycznych\nMetoda automatyczna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":315,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Wastewater Sampling for chemical and physical testing Automatic method PN-ISO 5667-10:2021-11","technique_en":"Automatic method","test_object_en":"Wastewater","methodology_zh":"化学与物理检测用样品采集","search_zh":"污水 化学与物理检测用样品采集 自动法 PN-ISO 5667-10:2021-11","test_object_zh":"污水","technique_zh":"自动法"},{"_id":"6a836fb9af14b9c0e7b1ec53","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Zespół Logistyki Włocławek LL/W","lab_address":null,"regulatory_area":"Badania wykonywane poza siedzibą laboratorium","flexible":false,"search_text":"Ścieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Scieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":316,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"search_en":"Wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Wastewater","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"污水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"污水"},{"_id":"6a836fb9af14b9c0e7b1ec54","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Wody powierzchniowe","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki","parameters":[{"name":"Zakres","range":"(2,0 – 50,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki\nZakres (2,0 – 50,0) °C","reference":"PN-EN ISO 5667-6:2016-12 z wyłączeniem 7.6, 9.4 Metoda nr 111 Wydanie 5 z dnia 01.07.2020","norm_bases":["PN-EN ISO 5667-6:2016-12 z wyłączeniem 7.6, 9.4 Metoda nr 111 Wydanie 5 z dnia 01.07.2020"],"lab_section":"Zespół Logistyki Włocławek LL/W","lab_address":null,"regulatory_area":"Badania wykonywane poza siedzibą laboratorium","flexible":false,"search_text":"Wody powierzchniowe Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki\nZakres (2,0 – 50,0) °C PN-EN ISO 5667-6:2016-12 z wyłączeniem 7.6, 9.4 Metoda nr 111 Wydanie 5 z dnia 01.07.2020 Wody powierzchniowe Pobieranie probek do badan chemicznych i fizycznych Temperatura pobranej probki\nZakres (2,0 – 50,0) °C PN-EN ISO 5667-6:2016-12 z wylaczeniem 7.6, 9.4 Metoda nr 111 Wydanie 5 z dnia 01.07.2020","categories":["water"],"row_index":317,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing Temperature of the sample taken","parameters_en":[{"name":"Range","range":"(2,0 – 50,0) °C"}],"search_en":"Surface waters Sampling for chemical and physical testing Temperature of the sample taken Range PN-EN ISO 5667-6:2016-12 z wyłączeniem 7.6, 9.4 Metoda nr 111 Wydanie 5 z dnia 01.07.2020","test_object_en":"Surface waters","parameters_zh":[{"name":"范围","range":"(2,0 – 50,0) °C"}],"search_zh":"地表水 用于化学与物理检验的采样 所采样品的温度 范围 PN-EN ISO 5667-6:2016-12 z wyłączeniem 7.6, 9.4 Metoda nr 111 Wydanie 5 z dnia 01.07.2020","methodology_zh":"用于化学与物理检验的采样 所采样品的温度","test_object_zh":"地表水"},{"_id":"6a836fb9af14b9c0e7b1ec55","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Wody powierzchniowe","methodology":"pH","parameters":[{"name":"Zakres","range":"(2,0 – 12,0)"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres (2,0 – 12,0)\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Zespół Logistyki Włocławek LL/W","lab_address":null,"regulatory_area":"Badania wykonywane poza siedzibą laboratorium","flexible":false,"search_text":"Wody powierzchniowe pH\nZakres (2,0 – 12,0)\nMetoda potencjometryczna PN-EN ISO 10523:2012 Wody powierzchniowe pH\nZakres (2,0 – 12,0)\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":318,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"(2,0 – 12,0)"}],"search_en":"Surface waters pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Surface waters","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"(2,0 – 12,0)"}],"search_zh":"地表水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"地表水"},{"_id":"6a836fb9af14b9c0e7b1ec56","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Wody powierzchniowe","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(0,100 – 20,00) mS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (0,100 – 20,00) mS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Zespół Logistyki Włocławek LL/W","lab_address":null,"regulatory_area":"Badania wykonywane poza siedzibą laboratorium","flexible":false,"search_text":"Wody powierzchniowe Przewodność elektryczna właściwa\nZakres (0,100 – 20,00) mS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Wody powierzchniowe Przewodnosc elektryczna wlasciwa\nZakres (0,100 – 20,00) mS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":319,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(0,100 – 20,00) mS/cm"}],"search_en":"Surface waters Electrical conductivity Conductometric method Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Surface waters","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(0,100 – 20,00) mS/cm"}],"search_zh":"地表水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"地表水"},{"_id":"6a836fb9af14b9c0e7b1ec57","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Wody podziemne","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki","parameters":[{"name":"Zakres","range":"(2,0 – 50,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki\nZakres (2,0 – 50,0) °C","reference":"PN-ISO 5667-11:2017-10 z wyłączeniem pkt 4.2.2, 4.2.4, 4.3, 6.2, 6.3 Metoda nr 111 Wydanie 5 z dnia 01.07.2020","norm_bases":["PN-ISO 5667-11:2017-10 z wyłączeniem pkt 4.2.2, 4.2.4, 4.3, 6.2, 6.3 Metoda nr 111 Wydanie 5 z dnia 01.07.2020"],"lab_section":"Zespół Logistyki Włocławek LL/W","lab_address":null,"regulatory_area":"Badania wykonywane poza siedzibą laboratorium","flexible":false,"search_text":"Wody podziemne Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki\nZakres (2,0 – 50,0) °C PN-ISO 5667-11:2017-10 z wyłączeniem pkt 4.2.2, 4.2.4, 4.3, 6.2, 6.3 Metoda nr 111 Wydanie 5 z dnia 01.07.2020 Wody podziemne Pobieranie probek do badan chemicznych i fizycznych Temperatura pobranej probki\nZakres (2,0 – 50,0) °C PN-ISO 5667-11:2017-10 z wylaczeniem pkt 4.2.2, 4.2.4, 4.3, 6.2, 6.3 Metoda nr 111 Wydanie 5 z dnia 01.07.2020","categories":["water"],"row_index":320,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing Temperature of the sample taken","parameters_en":[{"name":"Range","range":"(2,0 – 50,0) °C"}],"search_en":"Groundwater Sampling for chemical and physical testing Temperature of the sample taken Range PN-ISO 5667-11:2017-10 z wyłączeniem pkt 4.2.2, 4.2.4, 4.3, 6.2, 6.3 Metoda nr 111 Wydanie 5 z dnia 01.07.2020","test_object_en":"Groundwater","parameters_zh":[{"name":"范围","range":"(2,0 – 50,0) °C"}],"search_zh":"地下水 用于化学与物理检验的采样 所采样品的温度 范围 PN-ISO 5667-11:2017-10 z wyłączeniem pkt 4.2.2, 4.2.4, 4.3, 6.2, 6.3 Metoda nr 111 Wydanie 5 z dnia 01.07.2020","methodology_zh":"用于化学与物理检验的采样 所采样品的温度","test_object_zh":"地下水"},{"_id":"6a836fb9af14b9c0e7b1ec58","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Wody podziemne","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Zespół Logistyki Włocławek LL/W","lab_address":null,"regulatory_area":"Badania wykonywane poza siedzibą laboratorium","flexible":false,"search_text":"Wody podziemne pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Wody podziemne pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":321,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"search_en":"Groundwater pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Groundwater","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"地下水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"地下水"},{"_id":"6a836fb9af14b9c0e7b1ec59","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Wody podziemne","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(0,100 – 20,00) mS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (0,100 – 20,00) mS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Zespół Logistyki Włocławek LL/W","lab_address":null,"regulatory_area":"Badania wykonywane poza siedzibą laboratorium","flexible":false,"search_text":"Wody podziemne Przewodność elektryczna właściwa\nZakres (0,100 – 20,00) mS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Wody podziemne Przewodnosc elektryczna wlasciwa\nZakres (0,100 – 20,00) mS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":322,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(0,100 – 20,00) mS/cm"}],"search_en":"Groundwater Electrical conductivity Conductometric method Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Groundwater","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(0,100 – 20,00) mS/cm"}],"search_zh":"地下水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"地下水"},{"_id":"6a836fb9af14b9c0e7b1ec5a","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Wody, w tym wody do spożycia","methodology":"Pobieranie próbek do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007 z wył. punktów 4.4.2, 4.4.3, 4.4.4, 4.4.5, 4.4.6","norm_bases":["PN-EN ISO 19458:2007 z wył. punktów 4.4.2, 4.4.3, 4.4.4, 4.4.5, 4.4.6"],"lab_section":"Zespół Logistyki Włocławek LL/W","lab_address":null,"regulatory_area":"Badania wykonywane poza siedzibą laboratorium","flexible":false,"search_text":"Wody, w tym wody do spożycia Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 z wył. punktów 4.4.2, 4.4.3, 4.4.4, 4.4.5, 4.4.6 Wody, w tym wody do spozycia Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007 z wyl. punktow 4.4.2, 4.4.3, 4.4.4, 4.4.5, 4.4.6","categories":["water","microbiology"],"row_index":323,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for microbiological testing","search_en":"Waters, including drinking waters Sampling for microbiological testing PN-EN ISO 19458:2007 z wył. punktów 4.4.2, 4.4.3, 4.4.4, 4.4.5, 4.4.6","test_object_en":"Waters, including drinking waters","methodology_zh":"微生物检测用样品采集","search_zh":"微生物检测用样品采集 PN-EN ISO 19458:2007 z wył. punktów 4.4.2, 4.4.3, 4.4.4, 4.4.5, 4.4.6"},{"_id":"6a836fb9af14b9c0e7b1ec5b","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda do spożycia","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki","parameters":[{"name":"Zakres","range":"(2,0 – 30,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki\nZakres (2,0 – 30,0) °C","reference":"PN-ISO 5667-5:2017-10 Metoda nr 111 Wydanie 5 z dnia 01.07.2020","norm_bases":["PN-ISO 5667-5:2017-10 Metoda nr 111 Wydanie 5 z dnia 01.07.2020"],"lab_section":"Zespół Logistyki Włocławek LL/W","lab_address":null,"regulatory_area":"Badania wykonywane poza siedzibą laboratorium","flexible":false,"search_text":"Woda do spożycia Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki\nZakres (2,0 – 30,0) °C PN-ISO 5667-5:2017-10 Metoda nr 111 Wydanie 5 z dnia 01.07.2020 Woda do spozycia Pobieranie probek do badan chemicznych i fizycznych Temperatura pobranej probki\nZakres (2,0 – 30,0) °C PN-ISO 5667-5:2017-10 Metoda nr 111 Wydanie 5 z dnia 01.07.2020","categories":["water"],"row_index":324,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing Temperature of the sample taken","parameters_en":[{"name":"Range","range":"(2,0 – 30,0) °C"}],"search_en":"Drinking water Sampling for chemical and physical testing Temperature of the sample taken Range PN-ISO 5667-5:2017-10 Metoda nr 111 Wydanie 5 z dnia 01.07.2020","test_object_en":"Drinking water","parameters_zh":[{"name":"范围","range":"(2,0 – 30,0) °C"}],"search_zh":"饮用水 用于化学与物理检验的采样 所采样品的温度 范围 PN-ISO 5667-5:2017-10 Metoda nr 111 Wydanie 5 z dnia 01.07.2020","test_object_zh":"饮用水","methodology_zh":"用于化学与物理检验的采样 所采样品的温度"},{"_id":"6a836fb9af14b9c0e7b1ec5c","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie chloru wolnego Zakres: chlor wolny (0,20 – 1,6) mg/l","parameters":[],"technique":"Metoda kolorymetryczna","techniques":["Metoda kolorymetryczna"],"computed":[],"activity":"Stężenie chloru wolnego Zakres: chlor wolny (0,20 – 1,6) mg/l\nMetoda kolorymetryczna","reference":"Metoda nr 195 Wydanie 1 z dnia 26.09.2019 Test HACH Nr 8021 (chlor wolny)","norm_bases":["Metoda nr 195 Wydanie 1 z dnia 26.09.2019 Test HACH Nr 8021 (chlor wolny)"],"lab_section":"Zespół Logistyki Włocławek LL/W","lab_address":null,"regulatory_area":"Badania wykonywane poza siedzibą laboratorium","flexible":false,"search_text":"Woda Stężenie chloru wolnego Zakres: chlor wolny (0,20 – 1,6) mg/l\nMetoda kolorymetryczna Metoda nr 195 Wydanie 1 z dnia 26.09.2019 Test HACH Nr 8021 (chlor wolny) Woda Stezenie chloru wolnego Zakres: chlor wolny (0,20 – 1,6) mg/l\nMetoda kolorymetryczna Metoda nr 195 Wydanie 1 z dnia 26.09.2019 Test HACH Nr 8021 (chlor wolny)","categories":["water"],"row_index":325,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free chlorine concentration Range: free chlorine (0,20 – 1,6) mg/l","search_en":"Water Free chlorine concentration Range: free chlorine (0,20 – 1,6) mg/l Colorimetric method Metoda nr 195 Wydanie 1 z dnia 26.09.2019 Test HACH Nr 8021 (chlor wolny)","technique_en":"Colorimetric method","test_object_en":"Water","search_zh":"水 比色法 Metoda nr 195 Wydanie 1 z dnia 26.09.2019 Test HACH Nr 8021 (chlor wolny)","technique_zh":"比色法","test_object_zh":"水"},{"_id":"6a836fb9af14b9c0e7b1ec5d","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwo gazowe: wodór (automotive)","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[{"name":"ze zbiorników"},{"name":"ze stacji tankowania"},{"name":"z rurociągów na instalacji"}],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nze zbiorników\nze stacji tankowania\nz rurociągów na instalacji","reference":"ASTM D 7606-24a | ISO 21087:2019-06 p. 8 | ISO 19880-1:2020-03 załącznik K p. K1, K2, K3 | ISO 19880-09:2024 z wyłączeniem załącznika A, C, D, E, F","norm_bases":["ASTM D 7606-24a","ISO 21087:2019-06 p. 8","ISO 19880-1:2020-03 załącznik K p. K1, K2, K3","ISO 19880-09:2024 z wyłączeniem załącznika A, C, D, E, F"],"lab_section":"Zespół Logistyki Włocławek LL/W","lab_address":null,"regulatory_area":"Badania wykonywane poza siedzibą laboratorium","flexible":false,"search_text":"Paliwo gazowe: wodór (automotive) Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nze zbiorników\nze stacji tankowania\nz rurociągów na instalacji ASTM D 7606-24a | ISO 21087:2019-06 p. 8 | ISO 19880-1:2020-03 załącznik K p. K1, K2, K3 | ISO 19880-09:2024 z wyłączeniem załącznika A, C, D, E, F Paliwo gazowe: wodor (automotive) Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nze zbiornikow\nze stacji tankowania\nz rurociagow na instalacji ASTM D 7606-24a | ISO 21087:2019-06 p. 8 | ISO 19880-1:2020-03 zalacznik K p. K1, K2, K3 | ISO 19880-09:2024 z wylaczeniem zalacznika A, C, D, E, F","categories":["petro","automotive"],"row_index":326,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","parameters_en":[{"name":"from tanks"},{"name":"from the refuelling station"},{"name":"from pipelines in the installation"}],"search_en":"Gaseous fuel: hydrogen (automotive) Sampling for chemical and physical testing from tanks from the refuelling station from pipelines in the installation ASTM D 7606-24a | ISO 21087:2019-06 p. 8 | ISO 19880-1:2020-03 załącznik K p. K1, K2, K3 | ISO 19880-09:2024 z wyłączeniem załącznika A, C, D, E, F","test_object_en":"Gaseous fuel: hydrogen (automotive)","methodology_zh":"化学与物理检测用样品采集","search_zh":"化学与物理检测用样品采集 来自储罐 来自加气站 ASTM D 7606-24a | ISO 21087:2019-06 p. 8 | ISO 19880-1:2020-03 załącznik K p. K1, K2, K3 | ISO 19880-09:2024 z wyłączeniem załącznika A, C, D, E, F","parameters_zh":[{"name":"来自储罐"},{"name":"来自加气站"},{"name":"z rurociągów na instalacji"}]},{"_id":"6a836fb9af14b9c0e7b1ec5e","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwo gazowe: wodór (automotive)","methodology":"Pobieranie próbek do zawartości cząstek stałych","parameters":[{"name":"ze zbiorników"},{"name":"ze stacji tankowania"},{"name":"z rurociągów"}],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do zawartości cząstek stałych\nZakres:\nze zbiorników\nze stacji tankowania\nz rurociągów","reference":"ASTM D 7650-21 z wyłączeniem 7.9 | ISO 21087:2019-06 p. 8 | ISO 19880-1:2020-03 załącznik K p. K1, K2, K7 z wyłączeniem p. K.7.1 | ISO 19880-9:2024-07 z wyłączeniem załącznika A, B, C, E, F","norm_bases":["ASTM D 7650-21 z wyłączeniem 7.9","ISO 21087:2019-06 p. 8","ISO 19880-1:2020-03 załącznik K p. K1, K2, K7 z wyłączeniem p. K.7.1","ISO 19880-9:2024-07 z wyłączeniem załącznika A, B, C, E, F"],"lab_section":"Zespół Logistyki Włocławek LL/W","lab_address":null,"regulatory_area":"Badania wykonywane poza siedzibą laboratorium","flexible":false,"search_text":"Paliwo gazowe: wodór (automotive) Pobieranie próbek do zawartości cząstek stałych\nZakres:\nze zbiorników\nze stacji tankowania\nz rurociągów ASTM D 7650-21 z wyłączeniem 7.9 | ISO 21087:2019-06 p. 8 | ISO 19880-1:2020-03 załącznik K p. K1, K2, K7 z wyłączeniem p. K.7.1 | ISO 19880-9:2024-07 z wyłączeniem załącznika A, B, C, E, F Paliwo gazowe: wodor (automotive) Pobieranie probek do zawartosci czastek stalych\nZakres:\nze zbiornikow\nze stacji tankowania\nz rurociagow ASTM D 7650-21 z wylaczeniem 7.9 | ISO 21087:2019-06 p. 8 | ISO 19880-1:2020-03 zalacznik K p. K1, K2, K7 z wylaczeniem p. K.7.1 | ISO 19880-9:2024-07 z wylaczeniem zalacznika A, B, C, E, F","categories":["petro","automotive"],"row_index":327,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for particulate matter content","parameters_en":[{"name":"from tanks"},{"name":"from the refuelling station"},{"name":"from pipelines"}],"search_en":"Gaseous fuel: hydrogen (automotive) Sampling for particulate matter content from tanks from the refuelling station from pipelines ASTM D 7650-21 z wyłączeniem 7.9 | ISO 21087:2019-06 p. 8 | ISO 19880-1:2020-03 załącznik K p. K1, K2, K7 z wyłączeniem p. K.7.1 | ISO 19880-9:2024-07 z wyłączeniem załącznika A, B, C, E, F","test_object_en":"Gaseous fuel: hydrogen (automotive)","parameters_zh":[{"name":"来自储罐"},{"name":"来自加气站"},{"name":"z rurociągów"}],"search_zh":"来自储罐 来自加气站 ASTM D 7650-21 z wyłączeniem 7.9 | ISO 21087:2019-06 p. 8 | ISO 19880-1:2020-03 załącznik K p. K1, K2, K7 z wyłączeniem p. K.7.1 | ISO 19880-9:2024-07 z wyłączeniem załącznika A, B, C, E, F"},{"_id":"6a836fb9af14b9c0e7b1ec5f","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Wyroby chemiczne: kwas tereftalowy (PTA)","methodology":"Transparentność alkaliczna","parameters":[{"name":"Zakres","range":"(87,4 – 99,6)%"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Transparentność alkaliczna\nZakres (87,4 – 99,6)%\nMetoda spektrofotometryczna","reference":"Metoda nr 117 wydanie 4 z dnia 05.12.2025","norm_bases":["Metoda nr 117 wydanie 4 z dnia 05.12.2025"],"lab_section":"Pracownia PTA TT5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby chemiczne: kwas tereftalowy (PTA) Transparentność alkaliczna\nZakres (87,4 – 99,6)%\nMetoda spektrofotometryczna Metoda nr 117 wydanie 4 z dnia 05.12.2025 Wyroby chemiczne: kwas tereftalowy (PTA) Transparentnosc alkaliczna\nZakres (87,4 – 99,6)%\nMetoda spektrofotometryczna Metoda nr 117 wydanie 4 z dnia 05.12.2025","categories":["other"],"row_index":328,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Alkaline transparency","parameters_en":[{"name":"Range","range":"(87,4 – 99,6)%"}],"search_en":"Chemical products: terephthalic acid (PTA) Alkaline transparency Spectrophotometric method Range Metoda nr 117 wydanie 4 z dnia 05.12.2025","technique_en":"Spectrophotometric method","test_object_en":"Chemical products: terephthalic acid (PTA)","parameters_zh":[{"name":"范围","range":"(87,4 – 99,6)%"}],"search_zh":"化工产品：对苯二甲酸（PTA） 分光光度法 范围 Metoda nr 117 wydanie 4 z dnia 05.12.2025","technique_zh":"分光光度法","test_object_zh":"化工产品：对苯二甲酸（PTA）"},{"_id":"6a836fb9af14b9c0e7b1ec60","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Wyroby chemiczne: kwas tereftalowy (PTA)","methodology":"Zawartość pierwiastków","parameters":[{"name":"Ca","range":"(0,01 – 1,00) mg/kg"},{"name":"Co","range":"(0,01 – 1,00) mg/kg"},{"name":"Cr","range":"(0,01 – 1,00) mg/kg"},{"name":"Fe","range":"(0,01 – 1,00) mg/kg"},{"name":"Na","range":"(0,01 – 1,00) mg/kg"},{"name":"Ni","range":"(0,01 – 1,00) mg/kg"},{"name":"Mn","range":"(0,01 – 1,00) mg/kg"},{"name":"Mo","range":"(0,01 – 1,00) mg/kg"},{"name":"Sumaryczna zawartość pierwiastków (z obliczeń)"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość pierwiastków\nZakres:\nCa (0,01 – 1,00) mg/kg\nCo (0,01 – 1,00) mg/kg\nCr (0,01 – 1,00) mg/kg\nFe (0,01 – 1,00) mg/kg\nNa (0,01 – 1,00) mg/kg\nNi (0,01 – 1,00) mg/kg\nMn (0,01 – 1,00) mg/kg\nMo (0,01 – 1,00) mg/kg\nSumaryczna zawartość pierwiastków (z obliczeń)\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"Metoda 118 wyd. 7 z dnia 07.04.2026","norm_bases":["Metoda 118 wyd. 7 z dnia 07.04.2026"],"lab_section":"Pracownia PTA TT5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby chemiczne: kwas tereftalowy (PTA) Zawartość pierwiastków\nZakres:\nCa (0,01 – 1,00) mg/kg\nCo (0,01 – 1,00) mg/kg\nCr (0,01 – 1,00) mg/kg\nFe (0,01 – 1,00) mg/kg\nNa (0,01 – 1,00) mg/kg\nNi (0,01 – 1,00) mg/kg\nMn (0,01 – 1,00) mg/kg\nMo (0,01 – 1,00) mg/kg\nSumaryczna zawartość pierwiastków (z obliczeń)\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) Metoda 118 wyd. 7 z dnia 07.04.2026 Wyroby chemiczne: kwas tereftalowy (PTA) Zawartosc pierwiastkow\nZakres:\nCa (0,01 – 1,00) mg/kg\nCo (0,01 – 1,00) mg/kg\nCr (0,01 – 1,00) mg/kg\nFe (0,01 – 1,00) mg/kg\nNa (0,01 – 1,00) mg/kg\nNi (0,01 – 1,00) mg/kg\nMn (0,01 – 1,00) mg/kg\nMo (0,01 – 1,00) mg/kg\nSumaryczna zawartosc pierwiastkow (z obliczen)\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) Metoda 118 wyd. 7 z dnia 07.04.2026","categories":["other"],"row_index":329,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element content","parameters_en":[{"name":"Ca","range":"(0,01 – 1,00) mg/kg"},{"name":"Co","range":"(0,01 – 1,00) mg/kg"},{"name":"Cr","range":"(0,01 – 1,00) mg/kg"},{"name":"Fe","range":"(0,01 – 1,00) mg/kg"},{"name":"Na","range":"(0,01 – 1,00) mg/kg"},{"name":"Ni","range":"(0,01 – 1,00) mg/kg"},{"name":"Mn","range":"(0,01 – 1,00) mg/kg"},{"name":"Mo","range":"(0,01 – 1,00) mg/kg"},{"name":"Sumaryczna zawartość pierwiastków (z obliczeń)"}],"search_en":"Chemical products: terephthalic acid (PTA) Element content Inductively coupled plasma optical emission spectrometry (ICP-OES) Ca Co Cr Fe Na Ni Mn Mo Metoda 118 wyd. 7 z dnia 07.04.2026","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Chemical products: terephthalic acid (PTA)","methodology_zh":"元素含量","parameters_zh":[{"name":"Ca","range":"(0,01 – 1,00) mg/kg"},{"name":"Co","range":"(0,01 – 1,00) mg/kg"},{"name":"Cr","range":"(0,01 – 1,00) mg/kg"},{"name":"Fe","range":"(0,01 – 1,00) mg/kg"},{"name":"Na","range":"(0,01 – 1,00) mg/kg"},{"name":"Ni","range":"(0,01 – 1,00) mg/kg"},{"name":"Mn","range":"(0,01 – 1,00) mg/kg"},{"name":"Mo","range":"(0,01 – 1,00) mg/kg"},{"name":"Sumaryczna zawartość pierwiastków (z obliczeń)"}],"search_zh":"化工产品：对苯二甲酸（PTA） 元素含量 电感耦合等离子体原子发射光谱法（ICP-OES） Ca Co Cr Fe Na Ni Mn Mo Metoda 118 wyd. 7 z dnia 07.04.2026","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"化工产品：对苯二甲酸（PTA）"},{"_id":"6a836fb9af14b9c0e7b1ec61","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Wyroby chemiczne: kwas tereftalowy (PTA)","methodology":"Wygląd","parameters":[],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Wygląd\nMetoda wizualna","reference":"Metoda nr 122 wydanie 4 z dnia 05.12.2025","norm_bases":["Metoda nr 122 wydanie 4 z dnia 05.12.2025"],"lab_section":"Pracownia PTA TT5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby chemiczne: kwas tereftalowy (PTA) Wygląd\nMetoda wizualna Metoda nr 122 wydanie 4 z dnia 05.12.2025 Wyroby chemiczne: kwas tereftalowy (PTA) Wyglad\nMetoda wizualna Metoda nr 122 wydanie 4 z dnia 05.12.2025","categories":["other"],"row_index":330,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Appearance","search_en":"Chemical products: terephthalic acid (PTA) Appearance Visual method Metoda nr 122 wydanie 4 z dnia 05.12.2025","technique_en":"Visual method","test_object_en":"Chemical products: terephthalic acid (PTA)","search_zh":"化工产品：对苯二甲酸（PTA） 外观 目视法 Metoda nr 122 wydanie 4 z dnia 05.12.2025","technique_zh":"目视法","methodology_zh":"外观","test_object_zh":"化工产品：对苯二甲酸（PTA）"},{"_id":"6a836fb9af14b9c0e7b1ec62","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Wyroby chemiczne: kwas tereftalowy (PTA)","methodology":"Barwa w skali Pt-Co","parameters":[{"name":"Zakres","range":"5 – 15"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Barwa w skali Pt-Co\nZakres 5 – 15\nMetoda wizualna","reference":"Metoda nr 126 wydanie 4 z dnia 05.12.2025","norm_bases":["Metoda nr 126 wydanie 4 z dnia 05.12.2025"],"lab_section":"Pracownia PTA TT5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby chemiczne: kwas tereftalowy (PTA) Barwa w skali Pt-Co\nZakres 5 – 15\nMetoda wizualna Metoda nr 126 wydanie 4 z dnia 05.12.2025 Wyroby chemiczne: kwas tereftalowy (PTA) Barwa w skali Pt-Co\nZakres 5 – 15\nMetoda wizualna Metoda nr 126 wydanie 4 z dnia 05.12.2025","categories":["other"],"row_index":331,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Colour on the Pt-Co scale","parameters_en":[{"name":"Range","range":"5 – 15"}],"search_en":"Chemical products: terephthalic acid (PTA) Colour on the Pt-Co scale Visual method Range Metoda nr 126 wydanie 4 z dnia 05.12.2025","technique_en":"Visual method","test_object_en":"Chemical products: terephthalic acid (PTA)","parameters_zh":[{"name":"范围","range":"5 – 15"}],"search_zh":"化工产品：对苯二甲酸（PTA） 目视法 范围 Metoda nr 126 wydanie 4 z dnia 05.12.2025","technique_zh":"目视法","test_object_zh":"化工产品：对苯二甲酸（PTA）"},{"_id":"6a836fb9af14b9c0e7b1ec63","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Wyroby chemiczne: kwas tereftalowy (PTA)","methodology":"Zawartość wody","parameters":[{"name":"Zakres","range":"(0,10 – 1,00) %(m/m)"}],"technique":"Metoda miareczkowania potencjometrycznego","techniques":["Metoda miareczkowania potencjometrycznego"],"computed":[],"activity":"Zawartość wody\nZakres (0,10 – 1,00) %(m/m)\nMetoda miareczkowania potencjometrycznego","reference":"Metoda nr 127 wydanie 4 z dnia 05.12.2025","norm_bases":["Metoda nr 127 wydanie 4 z dnia 05.12.2025"],"lab_section":"Pracownia PTA TT5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby chemiczne: kwas tereftalowy (PTA) Zawartość wody\nZakres (0,10 – 1,00) %(m/m)\nMetoda miareczkowania potencjometrycznego Metoda nr 127 wydanie 4 z dnia 05.12.2025 Wyroby chemiczne: kwas tereftalowy (PTA) Zawartosc wody\nZakres (0,10 – 1,00) %(m/m)\nMetoda miareczkowania potencjometrycznego Metoda nr 127 wydanie 4 z dnia 05.12.2025","categories":["water"],"row_index":332,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water content","parameters_en":[{"name":"Range","range":"(0,10 – 1,00) %(m/m)"}],"search_en":"Chemical products: terephthalic acid (PTA) Water content Potentiometric titration method Range Metoda nr 127 wydanie 4 z dnia 05.12.2025","technique_en":"Potentiometric titration method","test_object_en":"Chemical products: terephthalic acid (PTA)","methodology_zh":"水分含量","parameters_zh":[{"name":"范围","range":"(0,10 – 1,00) %(m/m)"}],"search_zh":"化工产品：对苯二甲酸（PTA） 水分含量 电位滴定法 范围 Metoda nr 127 wydanie 4 z dnia 05.12.2025","technique_zh":"电位滴定法","test_object_zh":"化工产品：对苯二甲酸（PTA）"},{"_id":"6a836fb9af14b9c0e7b1ec64","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Wyroby chemiczne: kwas tereftalowy (PTA)","methodology":"Barwa b","parameters":[{"name":"Zakres","range":"(0,1 – 2,0)"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Barwa b\nZakres (0,1 – 2,0)\nMetoda spektrofotometryczna","reference":"Metoda nr 128 wydanie 4 z dnia 05.12.2025","norm_bases":["Metoda nr 128 wydanie 4 z dnia 05.12.2025"],"lab_section":"Pracownia PTA TT5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby chemiczne: kwas tereftalowy (PTA) Barwa b\nZakres (0,1 – 2,0)\nMetoda spektrofotometryczna Metoda nr 128 wydanie 4 z dnia 05.12.2025 Wyroby chemiczne: kwas tereftalowy (PTA) Barwa b\nZakres (0,1 – 2,0)\nMetoda spektrofotometryczna Metoda nr 128 wydanie 4 z dnia 05.12.2025","categories":["other"],"row_index":333,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Colour b","parameters_en":[{"name":"Range","range":"(0,1 – 2,0)"}],"search_en":"Chemical products: terephthalic acid (PTA) Colour b Spectrophotometric method Range Metoda nr 128 wydanie 4 z dnia 05.12.2025","technique_en":"Spectrophotometric method","test_object_en":"Chemical products: terephthalic acid (PTA)","parameters_zh":[{"name":"范围","range":"(0,1 – 2,0)"}],"search_zh":"化工产品：对苯二甲酸（PTA） 分光光度法 范围 Metoda nr 128 wydanie 4 z dnia 05.12.2025","technique_zh":"分光光度法","test_object_zh":"化工产品：对苯二甲酸（PTA）"},{"_id":"6a836fb9af14b9c0e7b1ec65","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Wyroby chemiczne: kwas tereftalowy (PTA)","methodology":"Delta Y","parameters":[{"name":"Zakres","range":"(1,0 – 10,0)"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Delta Y\nZakres (1,0 – 10,0)\nMetoda spektrofotometryczna","reference":"Metoda nr 129 wydanie 4 z dnia 05.12.2025","norm_bases":["Metoda nr 129 wydanie 4 z dnia 05.12.2025"],"lab_section":"Pracownia PTA TT5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby chemiczne: kwas tereftalowy (PTA) Delta Y\nZakres (1,0 – 10,0)\nMetoda spektrofotometryczna Metoda nr 129 wydanie 4 z dnia 05.12.2025 Wyroby chemiczne: kwas tereftalowy (PTA) Delta Y\nZakres (1,0 – 10,0)\nMetoda spektrofotometryczna Metoda nr 129 wydanie 4 z dnia 05.12.2025","categories":["other"],"row_index":334,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Delta Y","parameters_en":[{"name":"Range","range":"(1,0 – 10,0)"}],"search_en":"Chemical products: terephthalic acid (PTA) Delta Y Spectrophotometric method Range Metoda nr 129 wydanie 4 z dnia 05.12.2025","technique_en":"Spectrophotometric method","test_object_en":"Chemical products: terephthalic acid (PTA)","parameters_zh":[{"name":"范围","range":"(1,0 – 10,0)"}],"search_zh":"化工产品：对苯二甲酸（PTA） 分光光度法 范围 Metoda nr 129 wydanie 4 z dnia 05.12.2025","technique_zh":"分光光度法","test_object_zh":"化工产品：对苯二甲酸（PTA）"},{"_id":"6a836fb9af14b9c0e7b1ec66","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Wyroby chemiczne: kwas tereftalowy (PTA)","methodology":"Liczba kwasowa","parameters":[{"name":"Zakres","range":"(673 – 677) mg KOH/g"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Liczba kwasowa\nZakres (673 – 677) mg KOH/g\nMetoda miareczkowa","reference":"Metoda nr 130 wydanie 4 z dnia 05.12.2025","norm_bases":["Metoda nr 130 wydanie 4 z dnia 05.12.2025"],"lab_section":"Pracownia PTA TT5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby chemiczne: kwas tereftalowy (PTA) Liczba kwasowa\nZakres (673 – 677) mg KOH/g\nMetoda miareczkowa Metoda nr 130 wydanie 4 z dnia 05.12.2025 Wyroby chemiczne: kwas tereftalowy (PTA) Liczba kwasowa\nZakres (673 – 677) mg KOH/g\nMetoda miareczkowa Metoda nr 130 wydanie 4 z dnia 05.12.2025","categories":["other"],"row_index":335,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Acid value","parameters_en":[{"name":"Range","range":"(673 – 677) mg KOH/g"}],"search_en":"Chemical products: terephthalic acid (PTA) Acid value Titrimetric method Range Metoda nr 130 wydanie 4 z dnia 05.12.2025","technique_en":"Titrimetric method","test_object_en":"Chemical products: terephthalic acid (PTA)","parameters_zh":[{"name":"范围","range":"(673 – 677) mg KOH/g"}],"search_zh":"化工产品：对苯二甲酸（PTA） 酸值 滴定法 范围 Metoda nr 130 wydanie 4 z dnia 05.12.2025","technique_zh":"滴定法","methodology_zh":"酸值","test_object_zh":"化工产品：对苯二甲酸（PTA）"},{"_id":"6a836fb9af14b9c0e7b1ec67","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Wyroby chemiczne: kwas tereftalowy (PTA)","methodology":"Pozostałość po spopieleniu","parameters":[{"name":"Zakres","range":"(1 – 5) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Pozostałość po spopieleniu\nZakres (1 – 5) mg/kg\nMetoda wagowa","reference":"Metoda nr 132 wydanie 3 z dnia 12.01.2023","norm_bases":["Metoda nr 132 wydanie 3 z dnia 12.01.2023"],"lab_section":"Pracownia PTA TT5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby chemiczne: kwas tereftalowy (PTA) Pozostałość po spopieleniu\nZakres (1 – 5) mg/kg\nMetoda wagowa Metoda nr 132 wydanie 3 z dnia 12.01.2023 Wyroby chemiczne: kwas tereftalowy (PTA) Pozostalosc po spopieleniu\nZakres (1 – 5) mg/kg\nMetoda wagowa Metoda nr 132 wydanie 3 z dnia 12.01.2023","categories":["other"],"row_index":336,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Residue after incineration","parameters_en":[{"name":"Range","range":"(1 – 5) mg/kg"}],"search_en":"Chemical products: terephthalic acid (PTA) Residue after incineration Gravimetric method Range Metoda nr 132 wydanie 3 z dnia 12.01.2023","technique_en":"Gravimetric method","test_object_en":"Chemical products: terephthalic acid (PTA)","parameters_zh":[{"name":"范围","range":"(1 – 5) mg/kg"}],"search_zh":"化工产品：对苯二甲酸（PTA） 灰化残渣 重量法 范围 Metoda nr 132 wydanie 3 z dnia 12.01.2023","technique_zh":"重量法","methodology_zh":"灰化残渣","test_object_zh":"化工产品：对苯二甲酸（PTA）"},{"_id":"6a836fb9af14b9c0e7b1ec68","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Wyroby chemiczne: kwas tereftalowy (PTA)","methodology":"Wartość Dp50","parameters":[{"name":"Zakres","range":"(70 – 130) μm"}],"technique":"Metoda sitowa (i z obliczeń)","techniques":["Metoda sitowa (i z obliczeń)"],"computed":[],"activity":"Wartość Dp50\nZakres (70 – 130) μm\nMetoda sitowa (i z obliczeń)","reference":"Metoda nr 133 wydanie 4 z dnia 05.12.2025","norm_bases":["Metoda nr 133 wydanie 4 z dnia 05.12.2025"],"lab_section":"Pracownia PTA TT5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby chemiczne: kwas tereftalowy (PTA) Wartość Dp50\nZakres (70 – 130) μm\nMetoda sitowa (i z obliczeń) Metoda nr 133 wydanie 4 z dnia 05.12.2025 Wyroby chemiczne: kwas tereftalowy (PTA) Wartosc Dp50\nZakres (70 – 130) μm\nMetoda sitowa (i z obliczen) Metoda nr 133 wydanie 4 z dnia 05.12.2025","categories":["other"],"row_index":337,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dp50 value","parameters_en":[{"name":"Range","range":"(70 – 130) μm"}],"search_en":"Chemical products: terephthalic acid (PTA) Dp50 value Range Metoda nr 133 wydanie 4 z dnia 05.12.2025","test_object_en":"Chemical products: terephthalic acid (PTA)","parameters_zh":[{"name":"范围","range":"(70 – 130) μm"}],"search_zh":"化工产品：对苯二甲酸（PTA） 范围 Metoda nr 133 wydanie 4 z dnia 05.12.2025","test_object_zh":"化工产品：对苯二甲酸（PTA）"},{"_id":"6a836fb9af14b9c0e7b1ec69","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Zawartość ogólnego węgla organicznego","parameters":[{"name":"Zakres","range":"(0,3 – 24000) mg/l"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość ogólnego węgla organicznego\nZakres (0,3 – 24000) mg/l\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN 1484:1999","norm_bases":["PN-EN 1484:1999"],"lab_section":"Pracownia PTA TT5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Zawartość ogólnego węgla organicznego\nZakres (0,3 – 24000) mg/l\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN 1484:1999 Woda, scieki Zawartosc ogolnego wegla organicznego\nZakres (0,3 – 24000) mg/l\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN 1484:1999","categories":["water"],"row_index":338,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total organic carbon content","parameters_en":[{"name":"Range","range":"(0,3 – 24000) mg/l"}],"search_en":"Water, wastewater Total organic carbon content High-temperature combustion with IR detection Range PN-EN 1484:1999","technique_en":"High-temperature combustion with IR detection","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,3 – 24000) mg/l"}],"search_zh":"水、废水 高温燃烧红外检测法 范围 PN-EN 1484:1999","technique_zh":"高温燃烧红外检测法","test_object_zh":"水、废水"},{"_id":"6a836fb9af14b9c0e7b1ec6a","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki, Biopaliwa ciekłe: estry metylowe kwasów tłuszczowych, bioetanol","methodology":"Pobieranie próbek ze zbiorników do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek ze zbiorników do badań chemicznych i fizycznych","reference":"PN-EN ISO 3170:2025-12 z wyłączeniem 8.3.1.3 - 8.3.1.6, 8.3.1.8, 8.3.2, 8.7, 8.8,9.8, 10.6, 10.7","norm_bases":["PN-EN ISO 3170:2025-12 z wyłączeniem 8.3.1.3 - 8.3.1.6, 8.3.1.8, 8.3.2, 8.7, 8.8,9.8, 10.6, 10.7"],"lab_section":"Punkt Obsługi Laboratoryjnej we Wrocławiu PP7/5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki, Biopaliwa ciekłe: estry metylowe kwasów tłuszczowych, bioetanol Pobieranie próbek ze zbiorników do badań chemicznych i fizycznych PN-EN ISO 3170:2025-12 z wyłączeniem 8.3.1.3 - 8.3.1.6, 8.3.1.8, 8.3.2, 8.7, 8.8,9.8, 10.6, 10.7 Paliwa ciekle: benzyna bezolowiowa, olej napedowy, olej opalowy lekki, Biopaliwa ciekle: estry metylowe kwasow tluszczowych, bioetanol Pobieranie probek ze zbiornikow do badan chemicznych i fizycznych PN-EN ISO 3170:2025-12 z wylaczeniem 8.3.1.3 - 8.3.1.6, 8.3.1.8, 8.3.2, 8.7, 8.8,9.8, 10.6, 10.7","categories":["petro"],"row_index":339,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling from tanks for chemical and physical testing","search_en":"Liquid fuels: unleaded petrol, diesel fuel, light heating oil, Liquid biofuels: fatty acid methyl esters, bioethanol Sampling from tanks for chemical and physical testing PN-EN ISO 3170:2025-12 z wyłączeniem 8.3.1.3 - 8.3.1.6, 8.3.1.8, 8.3.2, 8.7, 8.8,9.8, 10.6, 10.7","test_object_en":"Liquid fuels: unleaded petrol, diesel fuel, light heating oil, Liquid biofuels: fatty acid methyl esters, bioethanol","methodology_zh":"自储罐采集化学和物理检测样品","search_zh":"自储罐采集化学和物理检测样品 PN-EN ISO 3170:2025-12 z wyłączeniem 8.3.1.3 - 8.3.1.6, 8.3.1.8, 8.3.2, 8.7, 8.8,9.8, 10.6, 10.7"},{"_id":"6a836fb9af14b9c0e7b1ec6b","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy","methodology":"Pobieranie próbek z dystrybutora do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek z dystrybutora do badań chemicznych i fizycznych","reference":"PN-EN 14275:2013-06","norm_bases":["PN-EN 14275:2013-06"],"lab_section":"Punkt Obsługi Laboratoryjnej we Wrocławiu PP7/5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy Pobieranie próbek z dystrybutora do badań chemicznych i fizycznych PN-EN 14275:2013-06 Paliwa ciekle: benzyna bezolowiowa, olej napedowy Pobieranie probek z dystrybutora do badan chemicznych i fizycznych PN-EN 14275:2013-06","categories":["petro"],"row_index":340,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling from a dispenser for chemical and physical testing","search_en":"Liquid fuels: unleaded petrol, diesel fuel Sampling from a dispenser for chemical and physical testing PN-EN 14275:2013-06","test_object_en":"Liquid fuels: unleaded petrol, diesel fuel","search_zh":"液体燃料：无铅汽油、柴油 PN-EN 14275:2013-06","test_object_zh":"液体燃料：无铅汽油、柴油"},{"_id":"6a836fb9af14b9c0e7b1ec6c","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki","methodology":"Zawartość siarki","parameters":[{"name":"Zakres","range":"(3,0 – 60) mg/kg"}],"technique":"Metoda fluorescencji w nadfiolecie","techniques":["Metoda fluorescencji w nadfiolecie"],"computed":[],"activity":"Zawartość siarki\nZakres (3,0 – 60) mg/kg\nMetoda fluorescencji w nadfiolecie","reference":"PN-EN ISO 20846:2020-03","norm_bases":["PN-EN ISO 20846:2020-03"],"lab_section":"Punkt Obsługi Laboratoryjnej we Wrocławiu PP7/5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki Zawartość siarki\nZakres (3,0 – 60) mg/kg\nMetoda fluorescencji w nadfiolecie PN-EN ISO 20846:2020-03 Paliwa ciekle: benzyna bezolowiowa, olej napedowy, olej opalowy lekki Zawartosc siarki\nZakres (3,0 – 60) mg/kg\nMetoda fluorescencji w nadfiolecie PN-EN ISO 20846:2020-03","categories":["petro"],"row_index":341,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfur content","parameters_en":[{"name":"Range","range":"(3,0 – 60) mg/kg"}],"search_en":"Liquid fuels: unleaded petrol, diesel fuel, light fuel oil Sulfur content Ultraviolet fluorescence method Range PN-EN ISO 20846:2020-03","technique_en":"Ultraviolet fluorescence method","test_object_en":"Liquid fuels: unleaded petrol, diesel fuel, light fuel oil","parameters_zh":[{"name":"范围","range":"(3,0 – 60) mg/kg"}],"search_zh":"液体燃料：无铅汽油、柴油、轻质燃料油 硫含量 紫外荧光法 范围 PN-EN ISO 20846:2020-03","methodology_zh":"硫含量","technique_zh":"紫外荧光法","test_object_zh":"液体燃料：无铅汽油、柴油、轻质燃料油"},{"_id":"6a836fb9af14b9c0e7b1ec6d","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki","methodology":"Gęstość w temperaturze 15°C","parameters":[{"name":"Zakres","range":"(700,0 – 900,0) kg/m3"}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"computed":[],"activity":"Gęstość w temperaturze 15°C\nZakres (700,0 – 900,0) kg/m3\nMetoda oscylacyjna","reference":"PN-EN ISO 12185:2024-08","norm_bases":["PN-EN ISO 12185:2024-08"],"lab_section":"Punkt Obsługi Laboratoryjnej we Wrocławiu PP7/5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki Gęstość w temperaturze 15°C\nZakres (700,0 – 900,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08 Paliwa ciekle: benzyna bezolowiowa, olej napedowy, olej opalowy lekki Gestosc w temperaturze 15°C\nZakres (700,0 – 900,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08","categories":["petro"],"row_index":342,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Density at 15°C","parameters_en":[{"name":"Range","range":"(700,0 – 900,0) kg/m3"}],"search_en":"Liquid fuels: unleaded petrol, diesel fuel, light fuel oil Density at 15°C Oscillation method Range PN-EN ISO 12185:2024-08","technique_en":"Oscillation method","test_object_en":"Liquid fuels: unleaded petrol, diesel fuel, light fuel oil","parameters_zh":[{"name":"范围","range":"(700,0 – 900,0) kg/m3"}],"search_zh":"液体燃料：无铅汽油、柴油、轻质燃料油 15°C 时的密度 振荡法 范围 PN-EN ISO 12185:2024-08","technique_zh":"振荡法","methodology_zh":"15°C 时的密度","test_object_zh":"液体燃料：无铅汽油、柴油、轻质燃料油"},{"_id":"6a836fb9af14b9c0e7b1ec6e","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki","methodology":"Skład frakcyjny","parameters":[{"name":"Zakres","range":"(30,0 – 370,0) oC"}],"technique":"Metoda destylacyjna","techniques":["Metoda destylacyjna"],"computed":[],"activity":"Skład frakcyjny\nZakres (30,0 – 370,0) oC\nMetoda destylacyjna","reference":"PN-EN ISO 3405:2019-05","norm_bases":["PN-EN ISO 3405:2019-05"],"lab_section":"Punkt Obsługi Laboratoryjnej we Wrocławiu PP7/5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki Skład frakcyjny\nZakres (30,0 – 370,0) oC\nMetoda destylacyjna PN-EN ISO 3405:2019-05 Paliwa ciekle: benzyna bezolowiowa, olej napedowy, olej opalowy lekki Sklad frakcyjny\nZakres (30,0 – 370,0) oC\nMetoda destylacyjna PN-EN ISO 3405:2019-05","categories":["petro"],"row_index":343,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fractional composition","parameters_en":[{"name":"Range","range":"(30,0 – 370,0) oC"}],"search_en":"Liquid fuels: unleaded petrol, diesel fuel, light fuel oil Fractional composition Distillation method Range PN-EN ISO 3405:2019-05","technique_en":"Distillation method","test_object_en":"Liquid fuels: unleaded petrol, diesel fuel, light fuel oil","parameters_zh":[{"name":"范围","range":"(30,0 – 370,0) oC"}],"search_zh":"液体燃料：无铅汽油、柴油、轻质燃料油 馏程组成 蒸馏法 范围 PN-EN ISO 3405:2019-05","technique_zh":"蒸馏法","methodology_zh":"馏程组成","test_object_zh":"液体燃料：无铅汽油、柴油、轻质燃料油"},{"_id":"6a836fb9af14b9c0e7b1ec6f","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Prężność par nasyconych powietrzem","parameters":[{"name":"Zakres","range":"(40,0 – 106,0) kPa"}],"technique":"Metoda mini Reid","techniques":["Metoda mini Reid"],"computed":[],"activity":"Prężność par nasyconych powietrzem\nZakres (40,0 – 106,0) kPa\nMetoda mini Reid","reference":"PN-EN 13016-1:2024-11","norm_bases":["PN-EN 13016-1:2024-11"],"lab_section":"Punkt Obsługi Laboratoryjnej we Wrocławiu PP7/5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Prężność par nasyconych powietrzem\nZakres (40,0 – 106,0) kPa\nMetoda mini Reid PN-EN 13016-1:2024-11 Paliwa ciekle: benzyna bezolowiowa Preznosc par nasyconych powietrzem\nZakres (40,0 – 106,0) kPa\nMetoda mini Reid PN-EN 13016-1:2024-11","categories":["petro","environment"],"row_index":344,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air saturated vapour pressure","parameters_en":[{"name":"Range","range":"(40,0 – 106,0) kPa"}],"search_en":"Liquid fuels: unleaded petrol Air saturated vapour pressure Mini Reid method Range PN-EN 13016-1:2024-11","technique_en":"Mini Reid method","test_object_en":"Liquid fuels: unleaded petrol","parameters_zh":[{"name":"范围","range":"(40,0 – 106,0) kPa"}],"search_zh":"液体燃料：无铅汽油 空气饱和蒸气压 迷你雷德法 范围 PN-EN 13016-1:2024-11","test_object_zh":"液体燃料：无铅汽油","technique_zh":"迷你雷德法","methodology_zh":"空气饱和蒸气压"},{"_id":"6a836fb9af14b9c0e7b1ec70","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Indeks lotności (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Indeks lotności (z obliczeń)","reference":"PN-EN 228+A1:2017-06 p. 5.5.2","norm_bases":["PN-EN 228+A1:2017-06 p. 5.5.2"],"lab_section":"Punkt Obsługi Laboratoryjnej we Wrocławiu PP7/5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Indeks lotności (z obliczeń) PN-EN 228+A1:2017-06 p. 5.5.2 Paliwa ciekle: benzyna bezolowiowa Indeks lotnosci (z obliczen) PN-EN 228+A1:2017-06 p. 5.5.2","categories":["petro"],"row_index":345,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Volatility index (calculated)","search_en":"Liquid fuels: unleaded petrol Volatility index (calculated) PN-EN 228+A1:2017-06 p. 5.5.2","test_object_en":"Liquid fuels: unleaded petrol","search_zh":"液体燃料：无铅汽油 挥发性指数（计算值） PN-EN 228+A1:2017-06 p. 5.5.2","test_object_zh":"液体燃料：无铅汽油","methodology_zh":"挥发性指数（计算值）"},{"_id":"6a836fb9af14b9c0e7b1ec71","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Zawartość tlenowych związków organicznych","parameters":[{"name":"Zakres","range":"(0,17 – 15,0) %(v/v)"},{"name":"Całkowita zawartość organicznie związanego tlenu (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość tlenowych związków organicznych\nZakres:\nZakres (0,17 – 15,0) %(v/v)\nCałkowita zawartość organicznie związanego tlenu (z obliczeń)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13132:2005","norm_bases":["PN-EN 13132:2005"],"lab_section":"Punkt Obsługi Laboratoryjnej we Wrocławiu PP7/5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Zawartość tlenowych związków organicznych\nZakres:\nZakres (0,17 – 15,0) %(v/v)\nCałkowita zawartość organicznie związanego tlenu (z obliczeń)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13132:2005 Paliwa ciekle: benzyna bezolowiowa Zawartosc tlenowych zwiazkow organicznych\nZakres:\nZakres (0,17 – 15,0) %(v/v)\nCalkowita zawartosc organicznie zwiazanego tlenu (z obliczen)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13132:2005","categories":["petro"],"row_index":346,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of oxygenated organic compounds","parameters_en":[{"name":"Range","range":"(0,17 – 15,0) %(v/v)"},{"name":"Total organically bound oxygen content (calculated)"}],"search_en":"Liquid fuels: unleaded petrol Content of oxygenated organic compounds Gas chromatography with flame ionization detection (GC-FID) Range Total organically bound oxygen content (calculated) PN-EN 13132:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Liquid fuels: unleaded petrol","parameters_zh":[{"name":"范围","range":"(0,17 – 15,0) %(v/v)"},{"name":"有机结合氧总量（由计算得出）"}],"search_zh":"液体燃料：无铅汽油 含氧有机化合物含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 有机结合氧总量（由计算得出） PN-EN 13132:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"液体燃料：无铅汽油","methodology_zh":"含氧有机化合物含量"},{"_id":"6a836fb9af14b9c0e7b1ec72","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki","methodology":"Temperatura zapłonu","parameters":[{"name":"Zakres","range":"(40,0 – 90,0) oC"}],"technique":"Metoda zamkniętego tygla Pensky’ego-Martensa","techniques":["Metoda zamkniętego tygla Pensky’ego-Martensa"],"computed":[],"activity":"Temperatura zapłonu\nZakres (40,0 – 90,0) oC\nMetoda zamkniętego tygla Pensky’ego-Martensa","reference":"PN-EN ISO 2719:2016-08+A1:2021-06","norm_bases":["PN-EN ISO 2719:2016-08+A1:2021-06"],"lab_section":"Punkt Obsługi Laboratoryjnej we Wrocławiu PP7/5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki Temperatura zapłonu\nZakres (40,0 – 90,0) oC\nMetoda zamkniętego tygla Pensky’ego-Martensa PN-EN ISO 2719:2016-08+A1:2021-06 Paliwa ciekle: olej napedowy, olej opalowy lekki Temperatura zaplonu\nZakres (40,0 – 90,0) oC\nMetoda zamknietego tygla Pensky’ego-Martensa PN-EN ISO 2719:2016-08+A1:2021-06","categories":["petro"],"row_index":347,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Flash point","parameters_en":[{"name":"Range","range":"(40,0 – 90,0) oC"}],"search_en":"Liquid fuels: diesel fuel, light fuel oil Flash point Pensky-Martens closed cup method Range PN-EN ISO 2719:2016-08+A1:2021-06","technique_en":"Pensky-Martens closed cup method","test_object_en":"Liquid fuels: diesel fuel, light fuel oil","parameters_zh":[{"name":"范围","range":"(40,0 – 90,0) oC"}],"search_zh":"液体燃料：柴油、轻质燃料油 闪点 宾斯基-马丁闭口杯法 范围 PN-EN ISO 2719:2016-08+A1:2021-06","methodology_zh":"闪点","test_object_zh":"液体燃料：柴油、轻质燃料油","technique_zh":"宾斯基-马丁闭口杯法"},{"_id":"6a836fb9af14b9c0e7b1ec73","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki","methodology":"Zawartość wody","parameters":[{"name":"Zakres","range":"(30 – 1000) mg/kg"}],"technique":"Metoda miareczkowania kulometrycznego","techniques":["Metoda miareczkowania kulometrycznego"],"computed":[],"activity":"Zawartość wody\nZakres (30 – 1000) mg/kg\nMetoda miareczkowania kulometrycznego","reference":"PN-EN ISO 12937:2005+Ap1:2021-11","norm_bases":["PN-EN ISO 12937:2005+Ap1:2021-11"],"lab_section":"Punkt Obsługi Laboratoryjnej we Wrocławiu PP7/5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki Zawartość wody\nZakres (30 – 1000) mg/kg\nMetoda miareczkowania kulometrycznego PN-EN ISO 12937:2005+Ap1:2021-11 Paliwa ciekle: olej napedowy, olej opalowy lekki Zawartosc wody\nZakres (30 – 1000) mg/kg\nMetoda miareczkowania kulometrycznego PN-EN ISO 12937:2005+Ap1:2021-11","categories":["petro","water"],"row_index":348,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water content","parameters_en":[{"name":"Range","range":"(30 – 1000) mg/kg"}],"search_en":"Liquid fuels: diesel fuel, light fuel oil Water content Coulometric titration method Range PN-EN ISO 12937:2005+Ap1:2021-11","technique_en":"Coulometric titration method","test_object_en":"Liquid fuels: diesel fuel, light fuel oil","methodology_zh":"水分含量","parameters_zh":[{"name":"范围","range":"(30 – 1000) mg/kg"}],"search_zh":"液体燃料：柴油、轻质燃料油 水分含量 库仑滴定法 范围 PN-EN ISO 12937:2005+Ap1:2021-11","technique_zh":"库仑滴定法","test_object_zh":"液体燃料：柴油、轻质燃料油"},{"_id":"6a836fb9af14b9c0e7b1ec74","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki","methodology":"Zawartość zanieczyszczeń","parameters":[{"name":"Zakres","range":"(12,0 – 26,0) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość zanieczyszczeń\nZakres (12,0 – 26,0) mg/kg\nMetoda wagowa","reference":"PN-EN 12662-1:2024-11","norm_bases":["PN-EN 12662-1:2024-11"],"lab_section":"Punkt Obsługi Laboratoryjnej we Wrocławiu PP7/5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki Zawartość zanieczyszczeń\nZakres (12,0 – 26,0) mg/kg\nMetoda wagowa PN-EN 12662-1:2024-11 Paliwa ciekle: olej napedowy, olej opalowy lekki Zawartosc zanieczyszczen\nZakres (12,0 – 26,0) mg/kg\nMetoda wagowa PN-EN 12662-1:2024-11","categories":["petro"],"row_index":349,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Impurity content","parameters_en":[{"name":"Range","range":"(12,0 – 26,0) mg/kg"}],"search_en":"Liquid fuels: diesel fuel, light fuel oil Impurity content Gravimetric method Range PN-EN 12662-1:2024-11","technique_en":"Gravimetric method","test_object_en":"Liquid fuels: diesel fuel, light fuel oil","parameters_zh":[{"name":"范围","range":"(12,0 – 26,0) mg/kg"}],"search_zh":"液体燃料：柴油、轻质燃料油 杂质含量 重量法 范围 PN-EN 12662-1:2024-11","technique_zh":"重量法","methodology_zh":"杂质含量","test_object_zh":"液体燃料：柴油、轻质燃料油"},{"_id":"6a836fb9af14b9c0e7b1ec75","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki","methodology":"Zawartość estrów metylowych kwasów tłuszczowych (FAME)","parameters":[{"name":"Zakres","range":"(3,0 – 20,0) %(v/v)"}],"technique":"Metoda spektrometrii w zakresie podczerwieni IR","techniques":["Metoda spektrometrii w zakresie podczerwieni IR"],"computed":[],"activity":"Zawartość estrów metylowych kwasów tłuszczowych (FAME)\nZakres (3,0 – 20,0) %(v/v)\nMetoda spektrometrii w zakresie podczerwieni IR","reference":"PN-EN 14078:2014-06","norm_bases":["PN-EN 14078:2014-06"],"lab_section":"Punkt Obsługi Laboratoryjnej we Wrocławiu PP7/5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki Zawartość estrów metylowych kwasów tłuszczowych (FAME)\nZakres (3,0 – 20,0) %(v/v)\nMetoda spektrometrii w zakresie podczerwieni IR PN-EN 14078:2014-06 Paliwa ciekle: olej napedowy, olej opalowy lekki Zawartosc estrow metylowych kwasow tluszczowych (FAME)\nZakres (3,0 – 20,0) %(v/v)\nMetoda spektrometrii w zakresie podczerwieni IR PN-EN 14078:2014-06","categories":["petro"],"row_index":350,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fatty acid methyl esters (FAME) content","parameters_en":[{"name":"Range","range":"(3,0 – 20,0) %(v/v)"}],"search_en":"Liquid fuels: diesel fuel, light fuel oil Fatty acid methyl esters (FAME) content Spectrometry method in the infrared range IR Range PN-EN 14078:2014-06","technique_en":"Spectrometry method in the infrared range IR","test_object_en":"Liquid fuels: diesel fuel, light fuel oil","parameters_zh":[{"name":"范围","range":"(3,0 – 20,0) %(v/v)"}],"search_zh":"液体燃料：柴油、轻质燃料油 脂肪酸甲酯（FAME）含量 红外光谱法 IR 范围 PN-EN 14078:2014-06","technique_zh":"红外光谱法 IR","test_object_zh":"液体燃料：柴油、轻质燃料油","methodology_zh":"脂肪酸甲酯（FAME）含量"},{"_id":"6a836fb9af14b9c0e7b1ec76","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Temperatura mętnienia","parameters":[{"name":"Zakres","range":"[(- 20) – 0] °C"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Temperatura mętnienia\nZakres [(- 20) – 0] °C\nMetoda optyczna","reference":"PN-EN ISO 3015:2019-06","norm_bases":["PN-EN ISO 3015:2019-06"],"lab_section":"Punkt Obsługi Laboratoryjnej we Wrocławiu PP7/5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Temperatura mętnienia\nZakres [(- 20) – 0] °C\nMetoda optyczna PN-EN ISO 3015:2019-06 Paliwa ciekle: olej napedowy, olej opalowy lekki, biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Temperatura metnienia\nZakres [(- 20) – 0] °C\nMetoda optyczna PN-EN ISO 3015:2019-06","categories":["petro"],"row_index":351,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Cloud point","parameters_en":[{"name":"Range","range":"[(- 20) – 0] °C"}],"search_en":"Liquid fuels: diesel fuel, light fuel oil, liquid biofuels: fatty acid methyl esters (FAME) Cloud point Optical method Range PN-EN ISO 3015:2019-06","technique_en":"Optical method","test_object_en":"Liquid fuels: diesel fuel, light fuel oil, liquid biofuels: fatty acid methyl esters (FAME)","parameters_zh":[{"name":"范围","range":"[(- 20) – 0] °C"}],"search_zh":"液体燃料：柴油、轻质燃料油；液体生物燃料：脂肪酸甲酯（FAME） 浊点 光学法 范围 PN-EN ISO 3015:2019-06","technique_zh":"光学法","methodology_zh":"浊点","test_object_zh":"液体燃料：柴油、轻质燃料油；液体生物燃料：脂肪酸甲酯（FAME）"},{"_id":"6a836fb9af14b9c0e7b1ec77","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy","methodology":"Stabilność oksydacyjna","parameters":[{"name":"Zakres","range":"(5,0 – 48,0) h"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Stabilność oksydacyjna\nZakres (5,0 – 48,0) h\nMetoda konduktometryczna","reference":"PN-EN 15751:2014-05","norm_bases":["PN-EN 15751:2014-05"],"lab_section":"Punkt Obsługi Laboratoryjnej we Wrocławiu PP7/5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy Stabilność oksydacyjna\nZakres (5,0 – 48,0) h\nMetoda konduktometryczna PN-EN 15751:2014-05 Paliwa ciekle: olej napedowy Stabilnosc oksydacyjna\nZakres (5,0 – 48,0) h\nMetoda konduktometryczna PN-EN 15751:2014-05","categories":["petro"],"row_index":352,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Oxidation stability","parameters_en":[{"name":"Range","range":"(5,0 – 48,0) h"}],"search_en":"Liquid fuels: diesel fuel Oxidation stability Conductometric method Range PN-EN 15751:2014-05","technique_en":"Conductometric method","test_object_en":"Liquid fuels: diesel fuel","parameters_zh":[{"name":"范围","range":"(5,0 – 48,0) h"}],"search_zh":"液体燃料：柴油 氧化安定性 电导法 范围 PN-EN 15751:2014-05","technique_zh":"电导法","test_object_zh":"液体燃料：柴油","methodology_zh":"氧化安定性"},{"_id":"6a836fb9af14b9c0e7b1ec78","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy","methodology":"Temperatura zablokowania zimnego filtra","parameters":[{"name":"Zakres","range":"[(- 40) – 0] °C"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Temperatura zablokowania zimnego filtra\nZakres [(- 40) – 0] °C\nMetoda optyczna","reference":"PN-EN 116:2015-09","norm_bases":["PN-EN 116:2015-09"],"lab_section":"Punkt Obsługi Laboratoryjnej we Wrocławiu PP7/5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy Temperatura zablokowania zimnego filtra\nZakres [(- 40) – 0] °C\nMetoda optyczna PN-EN 116:2015-09 Paliwa ciekle: olej napedowy Temperatura zablokowania zimnego filtra\nZakres [(- 40) – 0] °C\nMetoda optyczna PN-EN 116:2015-09","categories":["petro"],"row_index":353,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Cold filter plugging point","parameters_en":[{"name":"Range","range":"[(- 40) – 0] °C"}],"search_en":"Liquid fuels: diesel fuel Cold filter plugging point Optical method Range PN-EN 116:2015-09","technique_en":"Optical method","test_object_en":"Liquid fuels: diesel fuel","parameters_zh":[{"name":"范围","range":"[(- 40) – 0] °C"}],"search_zh":"液体燃料：柴油 冷滤点 光学法 范围 PN-EN 116:2015-09","technique_zh":"光学法","test_object_zh":"液体燃料：柴油","methodology_zh":"冷滤点"},{"_id":"6a836fb9af14b9c0e7b1ec79","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy","methodology":"Indeks cetanowy (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Indeks cetanowy (z obliczeń)","reference":"PN-EN ISO 4264:2018-08","norm_bases":["PN-EN ISO 4264:2018-08"],"lab_section":"Punkt Obsługi Laboratoryjnej we Wrocławiu PP7/5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy Indeks cetanowy (z obliczeń) PN-EN ISO 4264:2018-08 Paliwa ciekle: olej napedowy Indeks cetanowy (z obliczen) PN-EN ISO 4264:2018-08","categories":["petro"],"row_index":354,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Cetane index (calculated)","search_en":"Liquid fuels: diesel fuel Cetane index (calculated) PN-EN ISO 4264:2018-08","test_object_en":"Liquid fuels: diesel fuel","search_zh":"液体燃料：柴油 十六烷指数（计算值） PN-EN ISO 4264:2018-08","test_object_zh":"液体燃料：柴油","methodology_zh":"十六烷指数（计算值）"},{"_id":"6a836fb9af14b9c0e7b1ec7a","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej opałowy lekki","methodology":"Temperatura płynięcia","parameters":[{"name":"[(- 45)","range":"(-15)] °C"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Temperatura płynięcia\n[(- 45) (-15)] °C\nMetoda optyczna","reference":"PN-EN ISO 3016:2019-06","norm_bases":["PN-EN ISO 3016:2019-06"],"lab_section":"Punkt Obsługi Laboratoryjnej we Wrocławiu PP7/5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej opałowy lekki Temperatura płynięcia\n[(- 45) (-15)] °C\nMetoda optyczna PN-EN ISO 3016:2019-06 Paliwa ciekle: olej opalowy lekki Temperatura plyniecia\n[(- 45) (-15)] °C\nMetoda optyczna PN-EN ISO 3016:2019-06","categories":["petro"],"row_index":355,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Pour point","parameters_en":[{"name":"[(- 45)","range":"(-15)] °C"}],"search_en":"Liquid fuels: light fuel oil Pour point Optical method [(- 45) PN-EN ISO 3016:2019-06","technique_en":"Optical method","test_object_en":"Liquid fuels: light fuel oil","search_zh":"液体燃料：轻质燃料油 倾点 光学法 PN-EN ISO 3016:2019-06","technique_zh":"光学法","methodology_zh":"倾点","test_object_zh":"液体燃料：轻质燃料油"},{"_id":"6a836fb9af14b9c0e7b1ec7b","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej opałowy lekki","methodology":"Zawartość barwnika Solvent Red 19","parameters":[{"name":"Zakres","range":"(1,0 – 10,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość barwnika Solvent Red 19\nZakres (1,0 – 10,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-C-04426:2013-07 Metoda A","norm_bases":["PN-C-04426:2013-07 Metoda A"],"lab_section":"Punkt Obsługi Laboratoryjnej we Wrocławiu PP7/5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej opałowy lekki Zawartość barwnika Solvent Red 19\nZakres (1,0 – 10,0) mg/l\nMetoda spektrofotometryczna PN-C-04426:2013-07 Metoda A Paliwa ciekle: olej opalowy lekki Zawartosc barwnika Solvent Red 19\nZakres (1,0 – 10,0) mg/l\nMetoda spektrofotometryczna PN-C-04426:2013-07 Metoda A","categories":["petro"],"row_index":356,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Solvent Red 19 dye content","parameters_en":[{"name":"Range","range":"(1,0 – 10,0) mg/l"}],"search_en":"Liquid fuels: light fuel oil Solvent Red 19 dye content Spectrophotometric method Range PN-C-04426:2013-07 Metoda A","technique_en":"Spectrophotometric method","test_object_en":"Liquid fuels: light fuel oil","parameters_zh":[{"name":"范围","range":"(1,0 – 10,0) mg/l"}],"search_zh":"液体燃料：轻质燃料油 溶剂红 19 着色剂含量 分光光度法 范围 PN-C-04426:2013-07 Metoda A","technique_zh":"分光光度法","methodology_zh":"溶剂红 19 着色剂含量","test_object_zh":"液体燃料：轻质燃料油"},{"_id":"6a836fb9af14b9c0e7b1ec7c","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość siarki","parameters":[{"name":"Zakres","range":"(3,0 – 10,0) mg/kg"}],"technique":"Metoda fluorescencji w nadfiolecie","techniques":["Metoda fluorescencji w nadfiolecie"],"computed":[],"activity":"Zawartość siarki\nZakres (3,0 – 10,0) mg/kg\nMetoda fluorescencji w nadfiolecie","reference":"PN-EN ISO 20846:2020-03","norm_bases":["PN-EN ISO 20846:2020-03"],"lab_section":"Punkt Obsługi Laboratoryjnej we Wrocławiu PP7/5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Zawartość siarki\nZakres (3,0 – 10,0) mg/kg\nMetoda fluorescencji w nadfiolecie PN-EN ISO 20846:2020-03 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Zawartosc siarki\nZakres (3,0 – 10,0) mg/kg\nMetoda fluorescencji w nadfiolecie PN-EN ISO 20846:2020-03","categories":["petro"],"row_index":357,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfur content","parameters_en":[{"name":"Range","range":"(3,0 – 10,0) mg/kg"}],"search_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME) Sulfur content Ultraviolet fluorescence method Range PN-EN ISO 20846:2020-03","technique_en":"Ultraviolet fluorescence method","test_object_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME)","parameters_zh":[{"name":"范围","range":"(3,0 – 10,0) mg/kg"}],"search_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME） 硫含量 紫外荧光法 范围 PN-EN ISO 20846:2020-03","methodology_zh":"硫含量","technique_zh":"紫外荧光法","test_object_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME）"},{"_id":"6a836fb9af14b9c0e7b1ec7d","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Temperatura zablokowania zimnego filtra","parameters":[{"name":"Zakres","range":"[(- 20) – 0] °C"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Temperatura zablokowania zimnego filtra\nZakres [(- 20) – 0] °C\nMetoda optyczna","reference":"PN-EN 116:2015-09","norm_bases":["PN-EN 116:2015-09"],"lab_section":"Punkt Obsługi Laboratoryjnej we Wrocławiu PP7/5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Temperatura zablokowania zimnego filtra\nZakres [(- 20) – 0] °C\nMetoda optyczna PN-EN 116:2015-09 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Temperatura zablokowania zimnego filtra\nZakres [(- 20) – 0] °C\nMetoda optyczna PN-EN 116:2015-09","categories":["petro"],"row_index":358,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Cold filter plugging point","parameters_en":[{"name":"Range","range":"[(- 20) – 0] °C"}],"search_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME) Cold filter plugging point Optical method Range PN-EN 116:2015-09","technique_en":"Optical method","test_object_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME)","parameters_zh":[{"name":"范围","range":"[(- 20) – 0] °C"}],"search_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME） 冷滤点 光学法 范围 PN-EN 116:2015-09","technique_zh":"光学法","test_object_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME）","methodology_zh":"冷滤点"},{"_id":"6a836fb9af14b9c0e7b1ec7e","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość wody","parameters":[{"name":"Zakres","range":"(30 – 1000) mg/kg"}],"technique":"Metoda miareczkowania kulometrycznego","techniques":["Metoda miareczkowania kulometrycznego"],"computed":[],"activity":"Zawartość wody\nZakres (30 – 1000) mg/kg\nMetoda miareczkowania kulometrycznego","reference":"PN-EN ISO 12937:2005+Ap1:2021-11","norm_bases":["PN-EN ISO 12937:2005+Ap1:2021-11"],"lab_section":"Punkt Obsługi Laboratoryjnej we Wrocławiu PP7/5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Zawartość wody\nZakres (30 – 1000) mg/kg\nMetoda miareczkowania kulometrycznego PN-EN ISO 12937:2005+Ap1:2021-11 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Zawartosc wody\nZakres (30 – 1000) mg/kg\nMetoda miareczkowania kulometrycznego PN-EN ISO 12937:2005+Ap1:2021-11","categories":["petro","water"],"row_index":359,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water content","parameters_en":[{"name":"Range","range":"(30 – 1000) mg/kg"}],"search_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME) Water content Coulometric titration method Range PN-EN ISO 12937:2005+Ap1:2021-11","technique_en":"Coulometric titration method","test_object_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME)","methodology_zh":"水分含量","parameters_zh":[{"name":"范围","range":"(30 – 1000) mg/kg"}],"search_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME） 水分含量 库仑滴定法 范围 PN-EN ISO 12937:2005+Ap1:2021-11","technique_zh":"库仑滴定法","test_object_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME）"},{"_id":"6a836fb9af14b9c0e7b1ec7f","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Gęstość w temp. 15 °C","parameters":[{"name":"Zakres","range":"(850 – 900) kg/m3"}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"computed":[],"activity":"Gęstość w temp. 15 °C\nZakres (850 – 900) kg/m3\nMetoda oscylacyjna","reference":"PN-EN ISO 12185:2024-08","norm_bases":["PN-EN ISO 12185:2024-08"],"lab_section":"Punkt Obsługi Laboratoryjnej we Wrocławiu PP7/5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Gęstość w temp. 15 °C\nZakres (850 – 900) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Gestosc w temp. 15 °C\nZakres (850 – 900) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08","categories":["petro"],"row_index":360,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Density at 15 °C","parameters_en":[{"name":"Range","range":"(850 – 900) kg/m3"}],"search_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME) Density at 15 °C Oscillation method Range PN-EN ISO 12185:2024-08","technique_en":"Oscillation method","test_object_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME)","parameters_zh":[{"name":"范围","range":"(850 – 900) kg/m3"}],"search_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME） 振荡法 范围 PN-EN ISO 12185:2024-08","technique_zh":"振荡法","test_object_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME）"},{"_id":"6a836fb9af14b9c0e7b1ec80","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Skłonność do blokowania filtra po wychładzaniu","parameters":[{"name":"Zakres","range":"(50 – 720) s"}],"technique":"Metoda filtracji po wychłodzeniu","techniques":["Metoda filtracji po wychłodzeniu"],"computed":[],"activity":"Skłonność do blokowania filtra po wychładzaniu\nZakres (50 – 720) s\nMetoda filtracji po wychłodzeniu","reference":"ASTM D 7501-22","norm_bases":["ASTM D 7501-22"],"lab_section":"Punkt Obsługi Laboratoryjnej we Wrocławiu PP7/5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Skłonność do blokowania filtra po wychładzaniu\nZakres (50 – 720) s\nMetoda filtracji po wychłodzeniu ASTM D 7501-22 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Sklonnosc do blokowania filtra po wychladzaniu\nZakres (50 – 720) s\nMetoda filtracji po wychlodzeniu ASTM D 7501-22","categories":["petro"],"row_index":361,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Tendency to plug the filter after cooling","parameters_en":[{"name":"Range","range":"(50 – 720) s"}],"search_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME) Tendency to plug the filter after cooling Filtration after cooling method Range ASTM D 7501-22","technique_en":"Filtration after cooling method","test_object_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME)","parameters_zh":[{"name":"范围","range":"(50 – 720) s"}],"search_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME） 冷却后堵塞滤器的倾向 范围 ASTM D 7501-22","test_object_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME）","methodology_zh":"冷却后堵塞滤器的倾向"},{"_id":"6a836fb9af14b9c0e7b1ec81","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Stabilność oksydacyjna","parameters":[{"name":"Zakres","range":"(1,0 – 16,0) h"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Stabilność oksydacyjna\nZakres (1,0 – 16,0) h\nMetoda konduktometryczna","reference":"PN-EN 15751:2014-05","norm_bases":["PN-EN 15751:2014-05"],"lab_section":"Punkt Obsługi Laboratoryjnej we Wrocławiu PP7/5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Stabilność oksydacyjna\nZakres (1,0 – 16,0) h\nMetoda konduktometryczna PN-EN 15751:2014-05 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Stabilnosc oksydacyjna\nZakres (1,0 – 16,0) h\nMetoda konduktometryczna PN-EN 15751:2014-05","categories":["petro"],"row_index":362,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Oxidation stability","parameters_en":[{"name":"Range","range":"(1,0 – 16,0) h"}],"search_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME) Oxidation stability Conductometric method Range PN-EN 15751:2014-05","technique_en":"Conductometric method","test_object_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME)","parameters_zh":[{"name":"范围","range":"(1,0 – 16,0) h"}],"search_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME） 氧化安定性 电导法 范围 PN-EN 15751:2014-05","technique_zh":"电导法","methodology_zh":"氧化安定性","test_object_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME）"},{"_id":"6a836fb9af14b9c0e7b1ec82","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość zanieczyszczeń","parameters":[{"name":"Zakres","range":"(5,0 – 27,0) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość zanieczyszczeń\nZakres (5,0 – 27,0) mg/kg\nMetoda wagowa","reference":"PN-EN 12662-2:2024-11","norm_bases":["PN-EN 12662-2:2024-11"],"lab_section":"Punkt Obsługi Laboratoryjnej we Wrocławiu PP7/5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Zawartość zanieczyszczeń\nZakres (5,0 – 27,0) mg/kg\nMetoda wagowa PN-EN 12662-2:2024-11 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Zawartosc zanieczyszczen\nZakres (5,0 – 27,0) mg/kg\nMetoda wagowa PN-EN 12662-2:2024-11","categories":["petro"],"row_index":363,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Impurity content","parameters_en":[{"name":"Range","range":"(5,0 – 27,0) mg/kg"}],"search_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME) Impurity content Gravimetric method Range PN-EN 12662-2:2024-11","technique_en":"Gravimetric method","test_object_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME)","parameters_zh":[{"name":"范围","range":"(5,0 – 27,0) mg/kg"}],"search_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME） 杂质含量 重量法 范围 PN-EN 12662-2:2024-11","technique_zh":"重量法","methodology_zh":"杂质含量","test_object_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME）"},{"_id":"6a836fb9af14b9c0e7b1ec83","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: bioetanol","methodology":"Moc","parameters":[{"name":"Zakres","range":"(95,0 – 100,0) %(v/v)"}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"computed":[],"activity":"Moc\nZakres (95,0 – 100,0) %(v/v)\nMetoda oscylacyjna","reference":"PN-A-79528-3:2007 p. 5.2","norm_bases":["PN-A-79528-3:2007 p. 5.2"],"lab_section":"Punkt Obsługi Laboratoryjnej we Wrocławiu PP7/5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: bioetanol Moc\nZakres (95,0 – 100,0) %(v/v)\nMetoda oscylacyjna PN-A-79528-3:2007 p. 5.2 Paliwa ciekle: biopaliwa ciekle: bioetanol Moc\nZakres (95,0 – 100,0) %(v/v)\nMetoda oscylacyjna PN-A-79528-3:2007 p. 5.2","categories":["petro"],"row_index":364,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Power","parameters_en":[{"name":"Range","range":"(95,0 – 100,0) %(v/v)"}],"search_en":"Liquid fuels: liquid biofuels: bioethanol Power Oscillation method Range PN-A-79528-3:2007 p. 5.2","technique_en":"Oscillation method","test_object_en":"Liquid fuels: liquid biofuels: bioethanol","parameters_zh":[{"name":"范围","range":"(95,0 – 100,0) %(v/v)"}],"search_zh":"液体燃料：液体生物燃料：生物乙醇 功率 振荡法 范围 PN-A-79528-3:2007 p. 5.2","technique_zh":"振荡法","methodology_zh":"功率","test_object_zh":"液体燃料：液体生物燃料：生物乙醇"},{"_id":"6a836fb9af14b9c0e7b1ec84","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: bioetanol","methodology":"Gęstość w temperaturze 20°C","parameters":[{"name":"Zakres","range":"(789,0 – 830,0) kg/m3"}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"computed":[],"activity":"Gęstość w temperaturze 20°C\nZakres (789,0 – 830,0) kg/m3\nMetoda oscylacyjna","reference":"PN-EN ISO 12185:2024-08","norm_bases":["PN-EN ISO 12185:2024-08"],"lab_section":"Punkt Obsługi Laboratoryjnej we Wrocławiu PP7/5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: bioetanol Gęstość w temperaturze 20°C\nZakres (789,0 – 830,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08 Paliwa ciekle: biopaliwa ciekle: bioetanol Gestosc w temperaturze 20°C\nZakres (789,0 – 830,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08","categories":["petro"],"row_index":365,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Density at 20°C","parameters_en":[{"name":"Range","range":"(789,0 – 830,0) kg/m3"}],"search_en":"Liquid fuels: liquid biofuels: bioethanol Density at 20°C Oscillation method Range PN-EN ISO 12185:2024-08","technique_en":"Oscillation method","test_object_en":"Liquid fuels: liquid biofuels: bioethanol","parameters_zh":[{"name":"范围","range":"(789,0 – 830,0) kg/m3"}],"search_zh":"液体燃料：液体生物燃料：生物乙醇 振荡法 范围 PN-EN ISO 12185:2024-08","technique_zh":"振荡法","test_object_zh":"液体燃料：液体生物燃料：生物乙醇"},{"_id":"6a836fb9af14b9c0e7b1ec85","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Liczba oktanowa LOM","parameters":[{"name":"Zakres","range":"80,0 – 90,0"}],"technique":"Metoda silnikowa","techniques":["Metoda silnikowa"],"computed":[],"activity":"Liczba oktanowa LOM\nZakres 80,0 – 90,0\nMetoda silnikowa","reference":"PN-EN ISO 5163:2014-08","norm_bases":["PN-EN ISO 5163:2014-08"],"lab_section":"Punkt Obsługi Laboratoryjnej we Wrocławiu PP7/5 (Działalność techniczna)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Liczba oktanowa LOM\nZakres 80,0 – 90,0\nMetoda silnikowa PN-EN ISO 5163:2014-08 Paliwa ciekle: benzyna bezolowiowa Liczba oktanowa LOM\nZakres 80,0 – 90,0\nMetoda silnikowa PN-EN ISO 5163:2014-08","categories":["petro"],"row_index":366,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Motor octane number MON","parameters_en":[{"name":"Range","range":"80,0 – 90,0"}],"search_en":"Liquid fuels: unleaded petrol Motor octane number MON Motor method Range PN-EN ISO 5163:2014-08","technique_en":"Motor method","test_object_en":"Liquid fuels: unleaded petrol","parameters_zh":[{"name":"范围","range":"80,0 – 90,0"}],"search_zh":"液体燃料：无铅汽油 马达法辛烷值 MON 发动机法 范围 PN-EN ISO 5163:2014-08","technique_zh":"发动机法","test_object_zh":"液体燃料：无铅汽油","methodology_zh":"马达法辛烷值 MON"},{"_id":"6a836fb9af14b9c0e7b1ec86","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, olej opałowy lekki, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Pobieranie próbek ze zbiorników do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek ze zbiorników do badań chemicznych i fizycznych","reference":"PN-EN ISO 3170:2025-12 z wyłączeniem pkt 8.3.1.3- 8.3.1.5, 8.3.1.8, 8.3.2, 8.5 - 8.9, 9.8, 10.6, 10.7","norm_bases":["PN-EN ISO 3170:2025-12 z wyłączeniem pkt 8.3.1.3- 8.3.1.5, 8.3.1.8, 8.3.2, 8.5 - 8.9, 9.8, 10.6, 10.7"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, olej opałowy lekki, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Pobieranie próbek ze zbiorników do badań chemicznych i fizycznych PN-EN ISO 3170:2025-12 z wyłączeniem pkt 8.3.1.3- 8.3.1.5, 8.3.1.8, 8.3.2, 8.5 - 8.9, 9.8, 10.6, 10.7 Paliwa ciekle: olej napedowy, benzyna bezolowiowa, olej opalowy lekki, biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Pobieranie probek ze zbiornikow do badan chemicznych i fizycznych PN-EN ISO 3170:2025-12 z wylaczeniem pkt 8.3.1.3- 8.3.1.5, 8.3.1.8, 8.3.2, 8.5 - 8.9, 9.8, 10.6, 10.7","categories":["petro"],"row_index":367,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling from tanks for chemical and physical testing","search_en":"Liquid fuels: diesel fuel, unleaded petrol, light fuel oil, liquid biofuels: fatty acid methyl esters (FAME) Sampling from tanks for chemical and physical testing PN-EN ISO 3170:2025-12 z wyłączeniem pkt 8.3.1.3- 8.3.1.5, 8.3.1.8, 8.3.2, 8.5 - 8.9, 9.8, 10.6, 10.7","test_object_en":"Liquid fuels: diesel fuel, unleaded petrol, light fuel oil, liquid biofuels: fatty acid methyl esters (FAME)","methodology_zh":"自储罐采集化学和物理检测样品","search_zh":"自储罐采集化学和物理检测样品 PN-EN ISO 3170:2025-12 z wyłączeniem pkt 8.3.1.3- 8.3.1.5, 8.3.1.8, 8.3.2, 8.5 - 8.9, 9.8, 10.6, 10.7"},{"_id":"6a836fb9af14b9c0e7b1ec87","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej opałowy lekki, olej opałowy ciężki, Materiały smarne: olej silnikowy, przemysłowe oleje smarowe","methodology":"Temperatura płynięcia","parameters":[{"name":"Zakres","range":"(–38 – 40) °C"}],"technique":"Metoda optyczna, metoda wizualna","techniques":["Metoda optyczna, metoda wizualna"],"computed":[],"activity":"Temperatura płynięcia\nZakres (–38 – 40) °C\nMetoda optyczna, metoda wizualna","reference":"PN-EN ISO 3016:2019-06 | ASTM D 97-17b(2022)","norm_bases":["PN-EN ISO 3016:2019-06","ASTM D 97-17b(2022)"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej opałowy lekki, olej opałowy ciężki, Materiały smarne: olej silnikowy, przemysłowe oleje smarowe Temperatura płynięcia\nZakres (–38 – 40) °C\nMetoda optyczna, metoda wizualna PN-EN ISO 3016:2019-06 | ASTM D 97-17b(2022) Paliwa ciekle: olej opalowy lekki, olej opalowy ciezki, Materialy smarne: olej silnikowy, przemyslowe oleje smarowe Temperatura plyniecia\nZakres (–38 – 40) °C\nMetoda optyczna, metoda wizualna PN-EN ISO 3016:2019-06 | ASTM D 97-17b(2022)","categories":["petro","materials"],"row_index":368,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Pour point","parameters_en":[{"name":"Range","range":"(–38 – 40) °C"}],"search_en":"Pour point Optical method, visual method Range PN-EN ISO 3016:2019-06 | ASTM D 97-17b(2022)","technique_en":"Optical method, visual method","parameters_zh":[{"name":"范围","range":"(–38 – 40) °C"}],"search_zh":"倾点 范围 PN-EN ISO 3016:2019-06 | ASTM D 97-17b(2022)","methodology_zh":"倾点"},{"_id":"6a836fb9af14b9c0e7b1ec88","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej opałowy lekki, olej opałowy ciężki, Materiały smarne: olej silnikowy, przemysłowe oleje smarowe","methodology":"Zawartość siarki","parameters":[{"name":"Zakres","range":"(0,050 – 1,00) %(m/m)"}],"technique":"Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii","techniques":["Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii"],"computed":[],"activity":"Zawartość siarki\nZakres (0,050 – 1,00) %(m/m)\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii","reference":"PN –EN ISO 8754:2007+Ap1:2014-02","norm_bases":["PN –EN ISO 8754:2007+Ap1:2014-02"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej opałowy lekki, olej opałowy ciężki, Materiały smarne: olej silnikowy, przemysłowe oleje smarowe Zawartość siarki\nZakres (0,050 – 1,00) %(m/m)\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii PN –EN ISO 8754:2007+Ap1:2014-02 Paliwa ciekle: olej opalowy lekki, olej opalowy ciezki, Materialy smarne: olej silnikowy, przemyslowe oleje smarowe Zawartosc siarki\nZakres (0,050 – 1,00) %(m/m)\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersja energii PN –EN ISO 8754:2007+Ap1:2014-02","categories":["petro","materials"],"row_index":369,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfur content","parameters_en":[{"name":"Range","range":"(0,050 – 1,00) %(m/m)"}],"search_en":"Sulfur content Energy-dispersive X-ray fluorescence spectrometry Range PN –EN ISO 8754:2007+Ap1:2014-02","technique_en":"Energy-dispersive X-ray fluorescence spectrometry","parameters_zh":[{"name":"范围","range":"(0,050 – 1,00) %(m/m)"}],"search_zh":"硫含量 能量色散X射线荧光光谱法 范围 PN –EN ISO 8754:2007+Ap1:2014-02","methodology_zh":"硫含量","technique_zh":"能量色散X射线荧光光谱法"},{"_id":"6a836fb9af14b9c0e7b1ec89","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, olej opałowy lekki, olej opałowy ciężki, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME), Materiały smarne: olej silnikowy, przemysłowe oleje smarowe","methodology":"Gęstość","parameters":[{"name":"Zakres","range":"(700,0 – 950,0) kg/m3"}],"technique":"Metoda areometryczna","techniques":["Metoda areometryczna"],"computed":[],"activity":"Gęstość\nZakres (700,0 – 950,0) kg/m3\nMetoda areometryczna","reference":"PN-EN ISO 3675:2004","norm_bases":["PN-EN ISO 3675:2004"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, olej opałowy lekki, olej opałowy ciężki, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME), Materiały smarne: olej silnikowy, przemysłowe oleje smarowe Gęstość\nZakres (700,0 – 950,0) kg/m3\nMetoda areometryczna PN-EN ISO 3675:2004 Paliwa ciekle: olej napedowy, benzyna bezolowiowa, olej opalowy lekki, olej opalowy ciezki, biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME), Materialy smarne: olej silnikowy, przemyslowe oleje smarowe Gestosc\nZakres (700,0 – 950,0) kg/m3\nMetoda areometryczna PN-EN ISO 3675:2004","categories":["petro","materials"],"row_index":370,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Density","parameters_en":[{"name":"Range","range":"(700,0 – 950,0) kg/m3"}],"search_en":"Liquid fuels: diesel fuel, unleaded petrol, light fuel oil, heavy fuel oil, liquid biofuels: fatty acid methyl esters (FAME), Lubricants: engine oil, industrial lubricating oils Density Hydrometer method Range PN-EN ISO 3675:2004","technique_en":"Hydrometer method","test_object_en":"Liquid fuels: diesel fuel, unleaded petrol, light fuel oil, heavy fuel oil, liquid biofuels: fatty acid methyl esters (FAME), Lubricants: engine oil, industrial lubricating oils","methodology_zh":"密度","parameters_zh":[{"name":"范围","range":"(700,0 – 950,0) kg/m3"}],"search_zh":"密度 比重计法 范围 PN-EN ISO 3675:2004","technique_zh":"比重计法"},{"_id":"6a836fb9af14b9c0e7b1ec8a","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, olej opałowy lekki, olej opałowy ciężki, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME), Materiały smarne: olej silnikowy, przemysłowe oleje smarowe","methodology":"Gęstość w temperaturze 15°C i 20°C","parameters":[{"name":"Zakres","range":"(700,0 – 900,0) kg/m3"}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"computed":[],"activity":"Gęstość w temperaturze 15°C i 20°C\nZakres (700,0 – 900,0) kg/m3\nMetoda oscylacyjna","reference":"PN-EN ISO 12185:2024-08 | ASTM D 4052-22","norm_bases":["PN-EN ISO 12185:2024-08","ASTM D 4052-22"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, olej opałowy lekki, olej opałowy ciężki, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME), Materiały smarne: olej silnikowy, przemysłowe oleje smarowe Gęstość w temperaturze 15°C i 20°C\nZakres (700,0 – 900,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08 | ASTM D 4052-22 Paliwa ciekle: olej napedowy, benzyna bezolowiowa, olej opalowy lekki, olej opalowy ciezki, biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME), Materialy smarne: olej silnikowy, przemyslowe oleje smarowe Gestosc w temperaturze 15°C i 20°C\nZakres (700,0 – 900,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08 | ASTM D 4052-22","categories":["petro","materials"],"row_index":371,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Density at 15°C and 20°C","parameters_en":[{"name":"Range","range":"(700,0 – 900,0) kg/m3"}],"search_en":"Liquid fuels: diesel fuel, unleaded petrol, light fuel oil, heavy fuel oil, liquid biofuels: fatty acid methyl esters (FAME), Lubricants: engine oil, industrial lubricating oils Density at 15°C and 20°C Oscillation method Range PN-EN ISO 12185:2024-08 | ASTM D 4052-22","technique_en":"Oscillation method","test_object_en":"Liquid fuels: diesel fuel, unleaded petrol, light fuel oil, heavy fuel oil, liquid biofuels: fatty acid methyl esters (FAME), Lubricants: engine oil, industrial lubricating oils","parameters_zh":[{"name":"范围","range":"(700,0 – 900,0) kg/m3"}],"search_zh":"15°C 与 20°C 时的密度 振荡法 范围 PN-EN ISO 12185:2024-08 | ASTM D 4052-22","technique_zh":"振荡法","methodology_zh":"15°C 与 20°C 时的密度"},{"_id":"6a836fb9af14b9c0e7b1ec8b","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, olej opałowy ciężki, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME), Materiały smarne: olej silnikowy, przemysłowe oleje smarowe","methodology":"Lepkość kinematyczna w temperaturze 20°C, 40°C i 100°C","parameters":[{"name":"Zakres","range":"(1,500 – 100,0) mm2/s"},{"name":"Lepkość dynamiczna (z obliczeń)"}],"technique":"Metoda kapilarna","techniques":["Metoda kapilarna"],"computed":[],"activity":"Lepkość kinematyczna w temperaturze 20°C, 40°C i 100°C\nZakres:\nZakres (1,500 – 100,0) mm2/s\nLepkość dynamiczna (z obliczeń)\nMetoda kapilarna","reference":"PN-EN ISO 3104:2024-01","norm_bases":["PN-EN ISO 3104:2024-01"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, olej opałowy ciężki, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME), Materiały smarne: olej silnikowy, przemysłowe oleje smarowe Lepkość kinematyczna w temperaturze 20°C, 40°C i 100°C\nZakres:\nZakres (1,500 – 100,0) mm2/s\nLepkość dynamiczna (z obliczeń)\nMetoda kapilarna PN-EN ISO 3104:2024-01 Paliwa ciekle: olej napedowy, olej opalowy lekki, olej opalowy ciezki, biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME), Materialy smarne: olej silnikowy, przemyslowe oleje smarowe Lepkosc kinematyczna w temperaturze 20°C, 40°C i 100°C\nZakres:\nZakres (1,500 – 100,0) mm2/s\nLepkosc dynamiczna (z obliczen)\nMetoda kapilarna PN-EN ISO 3104:2024-01","categories":["petro","materials"],"row_index":372,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kinematic viscosity at 20°C, 40°C and 100°C","parameters_en":[{"name":"Range","range":"(1,500 – 100,0) mm2/s"},{"name":"Dynamic viscosity (calculated)"}],"search_en":"Liquid fuels: diesel fuel, light fuel oil, heavy fuel oil, liquid biofuels: fatty acid methyl esters (FAME), Lubricants: engine oil, industrial lubricating oils Kinematic viscosity at 20°C, 40°C and 100°C Capillary method Range Dynamic viscosity (calculated) PN-EN ISO 3104:2024-01","technique_en":"Capillary method","test_object_en":"Liquid fuels: diesel fuel, light fuel oil, heavy fuel oil, liquid biofuels: fatty acid methyl esters (FAME), Lubricants: engine oil, industrial lubricating oils","parameters_zh":[{"name":"范围","range":"(1,500 – 100,0) mm2/s"},{"name":"动力黏度（由计算得出）"}],"search_zh":"毛细管法 范围 动力黏度（由计算得出） PN-EN ISO 3104:2024-01","technique_zh":"毛细管法"},{"_id":"6a836fb9af14b9c0e7b1ec8c","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, olej opałowy ciężki, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME), Materiały smarne: olej silnikowy, przemysłowe oleje smarowe","methodology":"Lepkość kinematyczna w temp. 20 °C, 40 °C i 100 °C","parameters":[{"name":"Zakres","range":"(1,500 – 100,0) mm2/s"}],"technique":"Metoda kapilarna","techniques":["Metoda kapilarna"],"computed":[],"activity":"Lepkość kinematyczna w temp. 20 °C, 40 °C i 100 °C\nZakres (1,500 – 100,0) mm2/s\nMetoda kapilarna","reference":"ASTM D 445-24","norm_bases":["ASTM D 445-24"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, olej opałowy ciężki, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME), Materiały smarne: olej silnikowy, przemysłowe oleje smarowe Lepkość kinematyczna w temp. 20 °C, 40 °C i 100 °C\nZakres (1,500 – 100,0) mm2/s\nMetoda kapilarna ASTM D 445-24 Paliwa ciekle: olej napedowy, olej opalowy lekki, olej opalowy ciezki, biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME), Materialy smarne: olej silnikowy, przemyslowe oleje smarowe Lepkosc kinematyczna w temp. 20 °C, 40 °C i 100 °C\nZakres (1,500 – 100,0) mm2/s\nMetoda kapilarna ASTM D 445-24","categories":["petro","materials"],"row_index":373,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kinematic viscosity at 20 °C, 40 °C and 100 °C","parameters_en":[{"name":"Range","range":"(1,500 – 100,0) mm2/s"}],"search_en":"Liquid fuels: diesel fuel, light fuel oil, heavy fuel oil, liquid biofuels: fatty acid methyl esters (FAME), Lubricants: engine oil, industrial lubricating oils Kinematic viscosity at 20 °C, 40 °C and 100 °C Capillary method Range ASTM D 445-24","technique_en":"Capillary method","test_object_en":"Liquid fuels: diesel fuel, light fuel oil, heavy fuel oil, liquid biofuels: fatty acid methyl esters (FAME), Lubricants: engine oil, industrial lubricating oils","parameters_zh":[{"name":"范围","range":"(1,500 – 100,0) mm2/s"}],"search_zh":"毛细管法 范围 ASTM D 445-24","technique_zh":"毛细管法"},{"_id":"6a836fb9af14b9c0e7b1ec8d","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość wody","parameters":[{"name":"Zakres","range":"(0,003 – 0,100) %(m/m)"}],"technique":"Metoda miareczkowania kulometrycznego","techniques":["Metoda miareczkowania kulometrycznego"],"computed":[],"activity":"Zawartość wody\nZakres (0,003 – 0,100) %(m/m)\nMetoda miareczkowania kulometrycznego","reference":"PN-EN ISO 12937:2005+Ap1:2021-11","norm_bases":["PN-EN ISO 12937:2005+Ap1:2021-11"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Zawartość wody\nZakres (0,003 – 0,100) %(m/m)\nMetoda miareczkowania kulometrycznego PN-EN ISO 12937:2005+Ap1:2021-11 Paliwa ciekle: olej napedowy, olej opalowy lekki, biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Zawartosc wody\nZakres (0,003 – 0,100) %(m/m)\nMetoda miareczkowania kulometrycznego PN-EN ISO 12937:2005+Ap1:2021-11","categories":["petro","water"],"row_index":374,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water content","parameters_en":[{"name":"Range","range":"(0,003 – 0,100) %(m/m)"}],"search_en":"Liquid fuels: diesel fuel, light fuel oil, liquid biofuels: fatty acid methyl esters (FAME) Water content Coulometric titration method Range PN-EN ISO 12937:2005+Ap1:2021-11","technique_en":"Coulometric titration method","test_object_en":"Liquid fuels: diesel fuel, light fuel oil, liquid biofuels: fatty acid methyl esters (FAME)","methodology_zh":"水分含量","parameters_zh":[{"name":"范围","range":"(0,003 – 0,100) %(m/m)"}],"search_zh":"液体燃料：柴油、轻质燃料油；液体生物燃料：脂肪酸甲酯（FAME） 水分含量 库仑滴定法 范围 PN-EN ISO 12937:2005+Ap1:2021-11","technique_zh":"库仑滴定法","test_object_zh":"液体燃料：柴油、轻质燃料油；液体生物燃料：脂肪酸甲酯（FAME）"},{"_id":"6a836fb9af14b9c0e7b1ec8e","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Pozostałość po koksowaniu","parameters":[{"name":"Zakres","range":"(0,10 – 3,50) %(m/m)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Pozostałość po koksowaniu\nZakres (0,10 – 3,50) %(m/m)\nMetoda wagowa","reference":"PN-EN ISO 10370:2014-12","norm_bases":["PN-EN ISO 10370:2014-12"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Pozostałość po koksowaniu\nZakres (0,10 – 3,50) %(m/m)\nMetoda wagowa PN-EN ISO 10370:2014-12 Paliwa ciekle: olej napedowy, olej opalowy lekki, biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Pozostalosc po koksowaniu\nZakres (0,10 – 3,50) %(m/m)\nMetoda wagowa PN-EN ISO 10370:2014-12","categories":["petro"],"row_index":375,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Carbon residue","parameters_en":[{"name":"Range","range":"(0,10 – 3,50) %(m/m)"}],"search_en":"Liquid fuels: diesel fuel, light fuel oil, liquid biofuels: fatty acid methyl esters (FAME) Carbon residue Gravimetric method Range PN-EN ISO 10370:2014-12","technique_en":"Gravimetric method","test_object_en":"Liquid fuels: diesel fuel, light fuel oil, liquid biofuels: fatty acid methyl esters (FAME)","parameters_zh":[{"name":"范围","range":"(0,10 – 3,50) %(m/m)"}],"search_zh":"液体燃料：柴油、轻质燃料油；液体生物燃料：脂肪酸甲酯（FAME） 残炭 重量法 范围 PN-EN ISO 10370:2014-12","technique_zh":"重量法","methodology_zh":"残炭","test_object_zh":"液体燃料：柴油、轻质燃料油；液体生物燃料：脂肪酸甲酯（FAME）"},{"_id":"6a836fb9af14b9c0e7b1ec8f","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Temp. zablokowania zimnego filtru","parameters":[{"name":"Zakres","range":"(0 – (–30)) °C"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Temp. zablokowania zimnego filtru\nZakres (0 – (–30)) °C\nMetoda optyczna","reference":"PN-EN 116:2015-09","norm_bases":["PN-EN 116:2015-09"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Temp. zablokowania zimnego filtru\nZakres (0 – (–30)) °C\nMetoda optyczna PN-EN 116:2015-09 Paliwa ciekle: olej napedowy, olej opalowy lekki, biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Temp. zablokowania zimnego filtru\nZakres (0 – (–30)) °C\nMetoda optyczna PN-EN 116:2015-09","categories":["petro"],"row_index":376,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Cold filter plugging point","parameters_en":[{"name":"Range","range":"(0 – (–30)) °C"}],"search_en":"Liquid fuels: diesel fuel, light fuel oil, liquid biofuels: fatty acid methyl esters (FAME) Cold filter plugging point Optical method Range PN-EN 116:2015-09","technique_en":"Optical method","test_object_en":"Liquid fuels: diesel fuel, light fuel oil, liquid biofuels: fatty acid methyl esters (FAME)","parameters_zh":[{"name":"范围","range":"(0 – (–30)) °C"}],"search_zh":"液体燃料：柴油、轻质燃料油；液体生物燃料：脂肪酸甲酯（FAME） 光学法 范围 PN-EN 116:2015-09","technique_zh":"光学法","test_object_zh":"液体燃料：柴油、轻质燃料油；液体生物燃料：脂肪酸甲酯（FAME）"},{"_id":"6a836fb9af14b9c0e7b1ec90","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Temperatura mętnienia","parameters":[{"name":"Zakres","range":"(-38) – (+10) °C"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Temperatura mętnienia\nZakres (-38) – (+10) °C\nMetoda optyczna","reference":"PN-EN ISO 3015:2019-06","norm_bases":["PN-EN ISO 3015:2019-06"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Temperatura mętnienia\nZakres (-38) – (+10) °C\nMetoda optyczna PN-EN ISO 3015:2019-06 Paliwa ciekle: olej napedowy, olej opalowy lekki, biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Temperatura metnienia\nZakres (-38) – (+10) °C\nMetoda optyczna PN-EN ISO 3015:2019-06","categories":["petro"],"row_index":377,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Cloud point","parameters_en":[{"name":"Range","range":"(-38) – (+10) °C"}],"search_en":"Liquid fuels: diesel fuel, light fuel oil, liquid biofuels: fatty acid methyl esters (FAME) Cloud point Optical method Range PN-EN ISO 3015:2019-06","technique_en":"Optical method","test_object_en":"Liquid fuels: diesel fuel, light fuel oil, liquid biofuels: fatty acid methyl esters (FAME)","parameters_zh":[{"name":"范围","range":"(-38) – (+10) °C"}],"search_zh":"液体燃料：柴油、轻质燃料油；液体生物燃料：脂肪酸甲酯（FAME） 浊点 光学法 范围 PN-EN ISO 3015:2019-06","technique_zh":"光学法","methodology_zh":"浊点","test_object_zh":"液体燃料：柴油、轻质燃料油；液体生物燃料：脂肪酸甲酯（FAME）"},{"_id":"6a836fb9af14b9c0e7b1ec91","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki","methodology":"Zawartość zanieczyszczeń","parameters":[{"name":"Zakres","range":"(12,0 – 26,0) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość zanieczyszczeń\nZakres (12,0 – 26,0) mg/kg\nMetoda wagowa","reference":"PN-EN 12662-1:2024-11","norm_bases":["PN-EN 12662-1:2024-11"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki Zawartość zanieczyszczeń\nZakres (12,0 – 26,0) mg/kg\nMetoda wagowa PN-EN 12662-1:2024-11 Paliwa ciekle: olej napedowy, olej opalowy lekki Zawartosc zanieczyszczen\nZakres (12,0 – 26,0) mg/kg\nMetoda wagowa PN-EN 12662-1:2024-11","categories":["petro"],"row_index":378,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Impurity content","parameters_en":[{"name":"Range","range":"(12,0 – 26,0) mg/kg"}],"search_en":"Liquid fuels: diesel fuel, light fuel oil Impurity content Gravimetric method Range PN-EN 12662-1:2024-11","technique_en":"Gravimetric method","test_object_en":"Liquid fuels: diesel fuel, light fuel oil","parameters_zh":[{"name":"范围","range":"(12,0 – 26,0) mg/kg"}],"search_zh":"液体燃料：柴油、轻质燃料油 杂质含量 重量法 范围 PN-EN 12662-1:2024-11","technique_zh":"重量法","methodology_zh":"杂质含量","test_object_zh":"液体燃料：柴油、轻质燃料油"},{"_id":"6a836fb9af14b9c0e7b1ec92","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość zanieczyszczeń","parameters":[{"name":"Zakres","range":"(5,0 – 27,0) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość zanieczyszczeń\nZakres (5,0 – 27,0) mg/kg\nMetoda wagowa","reference":"PN-EN 12662-2:2024-11","norm_bases":["PN-EN 12662-2:2024-11"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Zawartość zanieczyszczeń\nZakres (5,0 – 27,0) mg/kg\nMetoda wagowa PN-EN 12662-2:2024-11 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Zawartosc zanieczyszczen\nZakres (5,0 – 27,0) mg/kg\nMetoda wagowa PN-EN 12662-2:2024-11","categories":["petro"],"row_index":379,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Impurity content","parameters_en":[{"name":"Range","range":"(5,0 – 27,0) mg/kg"}],"search_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME) Impurity content Gravimetric method Range PN-EN 12662-2:2024-11","technique_en":"Gravimetric method","test_object_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME)","parameters_zh":[{"name":"范围","range":"(5,0 – 27,0) mg/kg"}],"search_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME） 杂质含量 重量法 范围 PN-EN 12662-2:2024-11","technique_zh":"重量法","methodology_zh":"杂质含量","test_object_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME）"},{"_id":"6a836fb9af14b9c0e7b1ec93","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość siarki","parameters":[{"name":"Zakres","range":"(1,0 – 20,0) mg/kg"}],"technique":"Metoda fluorescencji w nadfiolecie","techniques":["Metoda fluorescencji w nadfiolecie"],"computed":[],"activity":"Zawartość siarki\nZakres (1,0 – 20,0) mg/kg\nMetoda fluorescencji w nadfiolecie","reference":"PN-EN ISO 20846:2020-03","norm_bases":["PN-EN ISO 20846:2020-03"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Zawartość siarki\nZakres (1,0 – 20,0) mg/kg\nMetoda fluorescencji w nadfiolecie PN-EN ISO 20846:2020-03 Paliwa ciekle: olej napedowy, benzyna bezolowiowa, biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Zawartosc siarki\nZakres (1,0 – 20,0) mg/kg\nMetoda fluorescencji w nadfiolecie PN-EN ISO 20846:2020-03","categories":["petro"],"row_index":380,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfur content","parameters_en":[{"name":"Range","range":"(1,0 – 20,0) mg/kg"}],"search_en":"Liquid fuels: diesel fuel, unleaded petrol, liquid biofuels: fatty acid methyl esters (FAME) Sulfur content Ultraviolet fluorescence method Range PN-EN ISO 20846:2020-03","technique_en":"Ultraviolet fluorescence method","test_object_en":"Liquid fuels: diesel fuel, unleaded petrol, liquid biofuels: fatty acid methyl esters (FAME)","parameters_zh":[{"name":"范围","range":"(1,0 – 20,0) mg/kg"}],"search_zh":"硫含量 紫外荧光法 范围 PN-EN ISO 20846:2020-03","methodology_zh":"硫含量","technique_zh":"紫外荧光法"},{"_id":"6a836fb9af14b9c0e7b1ec94","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME), Materiały smarne: olej silnikowy, przemysłowe oleje smarowe","methodology":"Zawartość popiołu siarczanowego","parameters":[{"name":"Zakres","range":"(0,005 – 2,00) %(m/m)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość popiołu siarczanowego\nZakres (0,005 – 2,00) %(m/m)\nMetoda wagowa","reference":"PN ISO 3987:2014-05","norm_bases":["PN ISO 3987:2014-05"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME), Materiały smarne: olej silnikowy, przemysłowe oleje smarowe Zawartość popiołu siarczanowego\nZakres (0,005 – 2,00) %(m/m)\nMetoda wagowa PN ISO 3987:2014-05 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME), Materialy smarne: olej silnikowy, przemyslowe oleje smarowe Zawartosc popiolu siarczanowego\nZakres (0,005 – 2,00) %(m/m)\nMetoda wagowa PN ISO 3987:2014-05","categories":["petro","materials"],"row_index":381,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfated ash content","parameters_en":[{"name":"Range","range":"(0,005 – 2,00) %(m/m)"}],"search_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME), Lubricants: engine oil, industrial lubricating oils Sulfated ash content Gravimetric method Range PN ISO 3987:2014-05","technique_en":"Gravimetric method","test_object_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME), Lubricants: engine oil, industrial lubricating oils","parameters_zh":[{"name":"范围","range":"(0,005 – 2,00) %(m/m)"}],"search_zh":"硫酸盐灰分含量 重量法 范围 PN ISO 3987:2014-05","technique_zh":"重量法","methodology_zh":"硫酸盐灰分含量"},{"_id":"6a836fb9af14b9c0e7b1ec95","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, olej opałowy ciężki","methodology":"Temperatura zapłonu","parameters":[{"name":"Zakres","range":"(40,0 – 250,0) °C"},{"name":"Pensky’ego-Martensa"}],"technique":"Metoda zamkniętego tygla","techniques":["Metoda zamkniętego tygla"],"computed":[],"activity":"Temperatura zapłonu\nZakres:\nZakres (40,0 – 250,0) °C\nPensky’ego-Martensa\nMetoda zamkniętego tygla","reference":"PN-EN ISO 2719:2016-08+A1: 2021-06 z wyłączeniem procedury C | ASTM D 93-25","norm_bases":["PN-EN ISO 2719:2016-08+A1: 2021-06 z wyłączeniem procedury C","ASTM D 93-25"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, olej opałowy ciężki Temperatura zapłonu\nZakres:\nZakres (40,0 – 250,0) °C\nPensky’ego-Martensa\nMetoda zamkniętego tygla PN-EN ISO 2719:2016-08+A1: 2021-06 z wyłączeniem procedury C | ASTM D 93-25 Paliwa ciekle: olej napedowy, olej opalowy lekki, olej opalowy ciezki Temperatura zaplonu\nZakres:\nZakres (40,0 – 250,0) °C\nPensky’ego-Martensa\nMetoda zamknietego tygla PN-EN ISO 2719:2016-08+A1: 2021-06 z wylaczeniem procedury C | ASTM D 93-25","categories":["petro"],"row_index":382,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Flash point","parameters_en":[{"name":"Range","range":"(40,0 – 250,0) °C"},{"name":"Pensky-Martens"}],"search_en":"Liquid fuels: diesel fuel, light fuel oil, heavy fuel oil Flash point Closed cup method Range Pensky-Martens PN-EN ISO 2719:2016-08+A1: 2021-06 z wyłączeniem procedury C | ASTM D 93-25","technique_en":"Closed cup method","test_object_en":"Liquid fuels: diesel fuel, light fuel oil, heavy fuel oil","parameters_zh":[{"name":"范围","range":"(40,0 – 250,0) °C"},{"name":"宾斯基-马丁"}],"search_zh":"闪点 闭口杯法 范围 宾斯基-马丁 PN-EN ISO 2719:2016-08+A1: 2021-06 z wyłączeniem procedury C | ASTM D 93-25","methodology_zh":"闪点","technique_zh":"闭口杯法"},{"_id":"6a836fb9af14b9c0e7b1ec96","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME), Materiały smarne: olej silnikowy, przemysłowe oleje smarowe","methodology":"Korozja na miedzi","parameters":[{"name":"klasa korozji","range":"(1 – 4)"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Korozja na miedzi\nklasa korozji (1 – 4)\nMetoda wizualna","reference":"PN-EN ISO 2160:2004 | ASTM D 130-19","norm_bases":["PN-EN ISO 2160:2004","ASTM D 130-19"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME), Materiały smarne: olej silnikowy, przemysłowe oleje smarowe Korozja na miedzi\nklasa korozji (1 – 4)\nMetoda wizualna PN-EN ISO 2160:2004 | ASTM D 130-19 Paliwa ciekle: benzyna bezolowiowa, biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME), Materialy smarne: olej silnikowy, przemyslowe oleje smarowe Korozja na miedzi\nklasa korozji (1 – 4)\nMetoda wizualna PN-EN ISO 2160:2004 | ASTM D 130-19","categories":["petro","materials"],"row_index":383,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Copper strip corrosion","parameters_en":[{"name":"corrosion class","range":"(1 – 4)"}],"search_en":"Liquid fuels: unleaded petrol, liquid biofuels: fatty acid methyl esters (FAME), Lubricants: engine oil, industrial lubricating oils Copper strip corrosion Visual method corrosion class PN-EN ISO 2160:2004 | ASTM D 130-19","technique_en":"Visual method","test_object_en":"Liquid fuels: unleaded petrol, liquid biofuels: fatty acid methyl esters (FAME), Lubricants: engine oil, industrial lubricating oils","search_zh":"目视法 腐蚀等级 PN-EN ISO 2160:2004 | ASTM D 130-19","technique_zh":"目视法","parameters_zh":[{"name":"腐蚀等级","range":"(1 – 4)"}]},{"_id":"6a836fb9af14b9c0e7b1ec97","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy","methodology":"Zawartość estrów metylowych kwasów tłuszczowych FAME","parameters":[{"name":"Zakres","range":"(0,05 – 10,0) %(v/v)"}],"technique":"Metoda spektrometrii w zakresie podczerwieni IR","techniques":["Metoda spektrometrii w zakresie podczerwieni IR"],"computed":[],"activity":"Zawartość estrów metylowych kwasów tłuszczowych FAME\nZakres (0,05 – 10,0) %(v/v)\nMetoda spektrometrii w zakresie podczerwieni IR","reference":"PN-EN 14078:2014-06","norm_bases":["PN-EN 14078:2014-06"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy Zawartość estrów metylowych kwasów tłuszczowych FAME\nZakres (0,05 – 10,0) %(v/v)\nMetoda spektrometrii w zakresie podczerwieni IR PN-EN 14078:2014-06 Paliwa ciekle: olej napedowy Zawartosc estrow metylowych kwasow tluszczowych FAME\nZakres (0,05 – 10,0) %(v/v)\nMetoda spektrometrii w zakresie podczerwieni IR PN-EN 14078:2014-06","categories":["petro"],"row_index":384,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fatty acid methyl ester FAME content","parameters_en":[{"name":"Range","range":"(0,05 – 10,0) %(v/v)"}],"search_en":"Liquid fuels: diesel fuel Fatty acid methyl ester FAME content Spectrometry method in the infrared range IR Range PN-EN 14078:2014-06","technique_en":"Spectrometry method in the infrared range IR","test_object_en":"Liquid fuels: diesel fuel","parameters_zh":[{"name":"范围","range":"(0,05 – 10,0) %(v/v)"}],"search_zh":"液体燃料：柴油 红外光谱法 IR 范围 PN-EN 14078:2014-06","test_object_zh":"液体燃料：柴油","technique_zh":"红外光谱法 IR"},{"_id":"6a836fb9af14b9c0e7b1ec98","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa","methodology":"Skład frakcyjny","parameters":[{"name":"Zakres","range":"(40,0 – 360,0) 0C"}],"technique":"Metoda destylacyjna","techniques":["Metoda destylacyjna"],"computed":[],"activity":"Skład frakcyjny\nZakres (40,0 – 360,0) 0C\nMetoda destylacyjna","reference":"PN-EN ISO 3405:2019-05","norm_bases":["PN-EN ISO 3405:2019-05"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa Skład frakcyjny\nZakres (40,0 – 360,0) 0C\nMetoda destylacyjna PN-EN ISO 3405:2019-05 Paliwa ciekle: olej napedowy, benzyna bezolowiowa Sklad frakcyjny\nZakres (40,0 – 360,0) 0C\nMetoda destylacyjna PN-EN ISO 3405:2019-05","categories":["petro"],"row_index":385,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fractional composition","parameters_en":[{"name":"Range","range":"(40,0 – 360,0) 0C"}],"search_en":"Liquid fuels: diesel fuel, unleaded petrol Fractional composition Distillation method Range PN-EN ISO 3405:2019-05","technique_en":"Distillation method","test_object_en":"Liquid fuels: diesel fuel, unleaded petrol","parameters_zh":[{"name":"范围","range":"(40,0 – 360,0) 0C"}],"search_zh":"馏程组成 蒸馏法 范围 PN-EN ISO 3405:2019-05","technique_zh":"蒸馏法","methodology_zh":"馏程组成"},{"_id":"6a836fb9af14b9c0e7b1ec99","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej opałowy lekki, olej opałowy ciężki","methodology":"Ciepło spalania","parameters":[{"name":"Zakres","range":"(35000 – 45000) kJ/kg"},{"name":"Wartość opałowa (z obliczeń)"}],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna"],"computed":[],"activity":"Ciepło spalania\nZakres:\nZakres (35000 – 45000) kJ/kg\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna","reference":"PN-C-04062:2018-05","norm_bases":["PN-C-04062:2018-05"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej opałowy lekki, olej opałowy ciężki Ciepło spalania\nZakres:\nZakres (35000 – 45000) kJ/kg\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna PN-C-04062:2018-05 Paliwa ciekle: olej opalowy lekki, olej opalowy ciezki Cieplo spalania\nZakres:\nZakres (35000 – 45000) kJ/kg\nWartosc opalowa (z obliczen)\nMetoda kalorymetryczna PN-C-04062:2018-05","categories":["petro"],"row_index":386,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gross calorific value","parameters_en":[{"name":"Range","range":"(35000 – 45000) kJ/kg"},{"name":"Net calorific value (calculated)"}],"search_en":"Liquid fuels: light heating oil, heavy heating oil Gross calorific value Calorimetric method Range Net calorific value (calculated) PN-C-04062:2018-05","technique_en":"Calorimetric method","test_object_en":"Liquid fuels: light heating oil, heavy heating oil","methodology_zh":"高位发热量","parameters_zh":[{"name":"范围","range":"(35000 – 45000) kJ/kg"},{"name":"低位发热量（计算值）"}],"search_zh":"高位发热量 量热法 范围 低位发热量（计算值） PN-C-04062:2018-05","technique_zh":"量热法"},{"_id":"6a836fb9af14b9c0e7b1ec9a","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej opałowy ciężki","methodology":"Zawartość żelaza, wanadu i niklu","parameters":[{"name":"Fe","range":"(1,00 – 150) mg/kg"},{"name":"V","range":"(1,00 – 150) mg/kg"},{"name":"Ni","range":"(1,00 – 150) mg/kg"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnej sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnej sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość żelaza, wanadu i niklu\nZakres:\nFe (1,00 – 150) mg/kg\nV (1,00 – 150) mg/kg\nNi (1,00 – 150) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnej sprzężonej (ICP-OES)","reference":"ASTM D 5708-15 (Reapproved 2020)e1 – Metoda A","norm_bases":["ASTM D 5708-15 (Reapproved 2020)e1 – Metoda A"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej opałowy ciężki Zawartość żelaza, wanadu i niklu\nZakres:\nFe (1,00 – 150) mg/kg\nV (1,00 – 150) mg/kg\nNi (1,00 – 150) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnej sprzężonej (ICP-OES) ASTM D 5708-15 (Reapproved 2020)e1 – Metoda A Paliwa ciekle: olej opalowy ciezki Zawartosc zelaza, wanadu i niklu\nZakres:\nFe (1,00 – 150) mg/kg\nV (1,00 – 150) mg/kg\nNi (1,00 – 150) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnej sprzezonej (ICP-OES) ASTM D 5708-15 (Reapproved 2020)e1 – Metoda A","categories":["petro"],"row_index":387,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of iron, vanadium and nickel","parameters_en":[{"name":"Fe","range":"(1,00 – 150) mg/kg"},{"name":"V","range":"(1,00 – 150) mg/kg"},{"name":"Ni","range":"(1,00 – 150) mg/kg"}],"search_en":"Liquid fuels: heavy fuel oil Content of iron, vanadium and nickel Inductively coupled plasma optical emission spectrometry (ICP-OES) Fe V Ni ASTM D 5708-15 (Reapproved 2020)e1 – Metoda A","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Liquid fuels: heavy fuel oil","parameters_zh":[{"name":"Fe","range":"(1,00 – 150) mg/kg"},{"name":"V","range":"(1,00 – 150) mg/kg"},{"name":"Ni","range":"(1,00 – 150) mg/kg"}],"search_zh":"液体燃料：重燃料油 电感耦合等离子体原子发射光谱法（ICP-OES） Fe V Ni ASTM D 5708-15 (Reapproved 2020)e1 – Metoda A","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"液体燃料：重燃料油"},{"_id":"6a836fb9af14b9c0e7b1ec9b","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Zawartość tlenowych związków organicznych","parameters":[{"name":"Zakres","range":"(0,17 – 15,0) %(m/m), %(v/v)"},{"name":"Całkowita zawartość organicznie związanego tlenu (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość tlenowych związków organicznych\nZakres:\nZakres (0,17 – 15,0) %(m/m), %(v/v)\nCałkowita zawartość organicznie związanego tlenu (z obliczeń)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13132:2005","norm_bases":["PN-EN 13132:2005"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Zawartość tlenowych związków organicznych\nZakres:\nZakres (0,17 – 15,0) %(m/m), %(v/v)\nCałkowita zawartość organicznie związanego tlenu (z obliczeń)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13132:2005 Paliwa ciekle: benzyna bezolowiowa Zawartosc tlenowych zwiazkow organicznych\nZakres:\nZakres (0,17 – 15,0) %(m/m), %(v/v)\nCalkowita zawartosc organicznie zwiazanego tlenu (z obliczen)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13132:2005","categories":["petro"],"row_index":388,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of oxygenated organic compounds","parameters_en":[{"name":"Range","range":"(0,17 – 15,0) %(m/m), %(v/v)"},{"name":"Total organically bound oxygen content (calculated)"}],"search_en":"Liquid fuels: unleaded petrol Content of oxygenated organic compounds Gas chromatography with flame ionization detection (GC-FID) Range Total organically bound oxygen content (calculated) PN-EN 13132:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Liquid fuels: unleaded petrol","parameters_zh":[{"name":"范围","range":"(0,17 – 15,0) %(m/m), %(v/v)"},{"name":"有机结合氧总量（由计算得出）"}],"search_zh":"液体燃料：无铅汽油 含氧有机化合物含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 有机结合氧总量（由计算得出） PN-EN 13132:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"液体燃料：无铅汽油","methodology_zh":"含氧有机化合物含量"},{"_id":"6a836fb9af14b9c0e7b1ec9c","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Prężność par nasyconych powietrzem","parameters":[{"name":"Zakres","range":"(30,0 – 106,0) kPa"}],"technique":"Metoda mini Reid","techniques":["Metoda mini Reid"],"computed":[],"activity":"Prężność par nasyconych powietrzem\nZakres (30,0 – 106,0) kPa\nMetoda mini Reid","reference":"PN-EN 13016-1:2024-11","norm_bases":["PN-EN 13016-1:2024-11"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Prężność par nasyconych powietrzem\nZakres (30,0 – 106,0) kPa\nMetoda mini Reid PN-EN 13016-1:2024-11 Paliwa ciekle: benzyna bezolowiowa Preznosc par nasyconych powietrzem\nZakres (30,0 – 106,0) kPa\nMetoda mini Reid PN-EN 13016-1:2024-11","categories":["petro","environment"],"row_index":389,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air saturated vapour pressure","parameters_en":[{"name":"Range","range":"(30,0 – 106,0) kPa"}],"search_en":"Liquid fuels: unleaded petrol Air saturated vapour pressure Mini Reid method Range PN-EN 13016-1:2024-11","technique_en":"Mini Reid method","test_object_en":"Liquid fuels: unleaded petrol","parameters_zh":[{"name":"范围","range":"(30,0 – 106,0) kPa"}],"search_zh":"液体燃料：无铅汽油 空气饱和蒸气压 迷你雷德法 范围 PN-EN 13016-1:2024-11","test_object_zh":"液体燃料：无铅汽油","technique_zh":"迷你雷德法","methodology_zh":"空气饱和蒸气压"},{"_id":"6a836fb9af14b9c0e7b1ec9d","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej opałowy lekki","methodology":"Zawartość butoksybenzenu (eteru n-butylofenylowego (BPE))","parameters":[{"name":"Zakres","range":"(1,00 – 15,00) mg/l"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrii mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrii mas (GC-MS)"],"computed":[],"activity":"Zawartość butoksybenzenu (eteru n-butylofenylowego (BPE))\nZakres (1,00 – 15,00) mg/l\nMetoda chromatografii gazowej z detekcją spektrometrii mas (GC-MS)","reference":"ILIADe 606:2024 Procedura B","norm_bases":["ILIADe 606:2024 Procedura B"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej opałowy lekki Zawartość butoksybenzenu (eteru n-butylofenylowego (BPE))\nZakres (1,00 – 15,00) mg/l\nMetoda chromatografii gazowej z detekcją spektrometrii mas (GC-MS) ILIADe 606:2024 Procedura B Paliwa ciekle: olej opalowy lekki Zawartosc butoksybenzenu (eteru n-butylofenylowego (BPE))\nZakres (1,00 – 15,00) mg/l\nMetoda chromatografii gazowej z detekcja spektrometrii mas (GC-MS) ILIADe 606:2024 Procedura B","categories":["petro"],"row_index":390,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Butoxybenzene (n-butyl phenyl ether (BPE)) content","parameters_en":[{"name":"Range","range":"(1,00 – 15,00) mg/l"}],"search_en":"Liquid fuels: light fuel oil Butoxybenzene (n-butyl phenyl ether (BPE)) content Gas chromatography with mass spectrometry detection (GC-MS) Range ILIADe 606:2024 Procedura B","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","test_object_en":"Liquid fuels: light fuel oil","parameters_zh":[{"name":"范围","range":"(1,00 – 15,00) mg/l"}],"search_zh":"液体燃料：轻质燃料油 气相色谱-质谱检测法（GC-MS） 范围 ILIADe 606:2024 Procedura B","technique_zh":"气相色谱-质谱检测法（GC-MS）","test_object_zh":"液体燃料：轻质燃料油"},{"_id":"6a836fb9af14b9c0e7b1ec9e","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiały smarne: oleje silnikowe, przemysłowe oleje smarowe","methodology":"Lepkość strukturalna w niskich temperaturach","parameters":[{"name":"Zakres","range":"(1300 – 10000) mPa∙s"}],"technique":"Metoda CCS","techniques":["Metoda CCS"],"computed":[],"activity":"Lepkość strukturalna w niskich temperaturach\nZakres (1300 – 10000) mPa∙s\nMetoda CCS","reference":"PN-C-04150:2004 | ASTM D 5293-20","norm_bases":["PN-C-04150:2004","ASTM D 5293-20"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały smarne: oleje silnikowe, przemysłowe oleje smarowe Lepkość strukturalna w niskich temperaturach\nZakres (1300 – 10000) mPa∙s\nMetoda CCS PN-C-04150:2004 | ASTM D 5293-20 Materialy smarne: oleje silnikowe, przemyslowe oleje smarowe Lepkosc strukturalna w niskich temperaturach\nZakres (1300 – 10000) mPa∙s\nMetoda CCS PN-C-04150:2004 | ASTM D 5293-20","categories":["materials","petro"],"row_index":391,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Structural viscosity at low temperatures","parameters_en":[{"name":"Range","range":"(1300 – 10000) mPa∙s"}],"search_en":"Lubricants: engine oils, industrial lubricating oils Structural viscosity at low temperatures CCS method Range PN-C-04150:2004 | ASTM D 5293-20","technique_en":"CCS method","test_object_en":"Lubricants: engine oils, industrial lubricating oils","parameters_zh":[{"name":"范围","range":"(1300 – 10000) mPa∙s"}],"search_zh":"润滑材料：发动机油、工业润滑油 范围 PN-C-04150:2004 | ASTM D 5293-20","test_object_zh":"润滑材料：发动机油、工业润滑油"},{"_id":"6a836fb9af14b9c0e7b1ec9f","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiały smarne: oleje silnikowe, przemysłowe oleje smarowe","methodology":"Całkowita liczba zasadowa","parameters":[{"name":"Zakres","range":"(1,0 -90,0) mg/g KOH"}],"technique":"Metoda miareczkowania potencjometrycznego","techniques":["Metoda miareczkowania potencjometrycznego"],"computed":[],"activity":"Całkowita liczba zasadowa\nZakres (1,0 -90,0) mg/g KOH\nMetoda miareczkowania potencjometrycznego","reference":"PN-ISO 3771:2012","norm_bases":["PN-ISO 3771:2012"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały smarne: oleje silnikowe, przemysłowe oleje smarowe Całkowita liczba zasadowa\nZakres (1,0 -90,0) mg/g KOH\nMetoda miareczkowania potencjometrycznego PN-ISO 3771:2012 Materialy smarne: oleje silnikowe, przemyslowe oleje smarowe Calkowita liczba zasadowa\nZakres (1,0 -90,0) mg/g KOH\nMetoda miareczkowania potencjometrycznego PN-ISO 3771:2012","categories":["materials","petro"],"row_index":392,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total base number","parameters_en":[{"name":"Range","range":"(1,0 -90,0) mg/g KOH"}],"search_en":"Lubricants: engine oils, industrial lubricating oils Total base number Potentiometric titration method Range PN-ISO 3771:2012","technique_en":"Potentiometric titration method","test_object_en":"Lubricants: engine oils, industrial lubricating oils","parameters_zh":[{"name":"范围","range":"(1,0 -90,0) mg/g KOH"}],"search_zh":"润滑材料：发动机油、工业润滑油 总碱值 电位滴定法 范围 PN-ISO 3771:2012","technique_zh":"电位滴定法","test_object_zh":"润滑材料：发动机油、工业润滑油","methodology_zh":"总碱值"},{"_id":"6a836fb9af14b9c0e7b1eca0","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiały smarne: oleje silnikowe, przemysłowe oleje smarowe","methodology":"Temperatura zapłonu","parameters":[{"name":"Zakres","range":"(180 – 270) °C"}],"technique":"Metoda otwartego tygla Clevelanda","techniques":["Metoda otwartego tygla Clevelanda"],"computed":[],"activity":"Temperatura zapłonu\nZakres (180 – 270) °C\nMetoda otwartego tygla Clevelanda","reference":"PN-EN ISO 2592:2017-10 | ASTM D 92-24","norm_bases":["PN-EN ISO 2592:2017-10","ASTM D 92-24"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały smarne: oleje silnikowe, przemysłowe oleje smarowe Temperatura zapłonu\nZakres (180 – 270) °C\nMetoda otwartego tygla Clevelanda PN-EN ISO 2592:2017-10 | ASTM D 92-24 Materialy smarne: oleje silnikowe, przemyslowe oleje smarowe Temperatura zaplonu\nZakres (180 – 270) °C\nMetoda otwartego tygla Clevelanda PN-EN ISO 2592:2017-10 | ASTM D 92-24","categories":["materials","petro"],"row_index":393,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Flash point","parameters_en":[{"name":"Range","range":"(180 – 270) °C"}],"search_en":"Lubricants: engine oils, industrial lubricating oils Flash point Cleveland open cup method Range PN-EN ISO 2592:2017-10 | ASTM D 92-24","technique_en":"Cleveland open cup method","test_object_en":"Lubricants: engine oils, industrial lubricating oils","parameters_zh":[{"name":"范围","range":"(180 – 270) °C"}],"search_zh":"润滑材料：发动机油、工业润滑油 闪点 克利夫兰开口杯法 范围 PN-EN ISO 2592:2017-10 | ASTM D 92-24","methodology_zh":"闪点","technique_zh":"克利夫兰开口杯法","test_object_zh":"润滑材料：发动机油、工业润滑油"},{"_id":"6a836fb9af14b9c0e7b1eca1","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiały smarne: oleje silnikowe, przemysłowe oleje smarowe","methodology":"Wskaźnik lepkości (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik lepkości (z obliczeń)","reference":"PN-ISO 2909:2009+Ap1:2010 | ASTM D 2270-24","norm_bases":["PN-ISO 2909:2009+Ap1:2010","ASTM D 2270-24"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały smarne: oleje silnikowe, przemysłowe oleje smarowe Wskaźnik lepkości (z obliczeń) PN-ISO 2909:2009+Ap1:2010 | ASTM D 2270-24 Materialy smarne: oleje silnikowe, przemyslowe oleje smarowe Wskaznik lepkosci (z obliczen) PN-ISO 2909:2009+Ap1:2010 | ASTM D 2270-24","categories":["materials","petro"],"row_index":394,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Viscosity index (calculated)","search_en":"Lubricants: engine oils, industrial lubricating oils Viscosity index (calculated) PN-ISO 2909:2009+Ap1:2010 | ASTM D 2270-24","test_object_en":"Lubricants: engine oils, industrial lubricating oils","methodology_zh":"黏度指数（由计算得出）","search_zh":"润滑材料：发动机油、工业润滑油 黏度指数（由计算得出） PN-ISO 2909:2009+Ap1:2010 | ASTM D 2270-24","test_object_zh":"润滑材料：发动机油、工业润滑油"},{"_id":"6a836fb9af14b9c0e7b1eca2","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiały smarne: oleje silnikowe, przemysłowe oleje smarowe","methodology":"Własności demulgujące","parameters":[{"name":"Zakres","range":"(5 – 60) min"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Własności demulgujące\nZakres (5 – 60) min\nMetoda wizualna","reference":"PN-ISO 6614:2010+A1:2022-05","norm_bases":["PN-ISO 6614:2010+A1:2022-05"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały smarne: oleje silnikowe, przemysłowe oleje smarowe Własności demulgujące\nZakres (5 – 60) min\nMetoda wizualna PN-ISO 6614:2010+A1:2022-05 Materialy smarne: oleje silnikowe, przemyslowe oleje smarowe Wlasnosci demulgujace\nZakres (5 – 60) min\nMetoda wizualna PN-ISO 6614:2010+A1:2022-05","categories":["materials","petro"],"row_index":395,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Demulsibility properties","parameters_en":[{"name":"Range","range":"(5 – 60) min"}],"search_en":"Lubricants: engine oils, industrial lubricating oils Demulsibility properties Visual method Range PN-ISO 6614:2010+A1:2022-05","technique_en":"Visual method","test_object_en":"Lubricants: engine oils, industrial lubricating oils","parameters_zh":[{"name":"范围","range":"(5 – 60) min"}],"search_zh":"润滑材料：发动机油、工业润滑油 目视法 范围 PN-ISO 6614:2010+A1:2022-05","technique_zh":"目视法","test_object_zh":"润滑材料：发动机油、工业润滑油"},{"_id":"6a836fb9af14b9c0e7b1eca3","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiały smarne: oleje silnikowe, przemysłowe oleje smarowe","methodology":"Liczba kwasowa","parameters":[{"name":"Zakres","range":"(0,1 – 5,0) mg/g KOH"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Liczba kwasowa\nZakres (0,1 – 5,0) mg/g KOH\nMetoda miareczkowa","reference":"PN-ISO 6618:2011","norm_bases":["PN-ISO 6618:2011"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały smarne: oleje silnikowe, przemysłowe oleje smarowe Liczba kwasowa\nZakres (0,1 – 5,0) mg/g KOH\nMetoda miareczkowa PN-ISO 6618:2011 Materialy smarne: oleje silnikowe, przemyslowe oleje smarowe Liczba kwasowa\nZakres (0,1 – 5,0) mg/g KOH\nMetoda miareczkowa PN-ISO 6618:2011","categories":["materials","petro"],"row_index":396,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Acid value","parameters_en":[{"name":"Range","range":"(0,1 – 5,0) mg/g KOH"}],"search_en":"Lubricants: engine oils, industrial lubricating oils Acid value Titrimetric method Range PN-ISO 6618:2011","technique_en":"Titrimetric method","test_object_en":"Lubricants: engine oils, industrial lubricating oils","parameters_zh":[{"name":"范围","range":"(0,1 – 5,0) mg/g KOH"}],"search_zh":"润滑材料：发动机油、工业润滑油 酸值 滴定法 范围 PN-ISO 6618:2011","technique_zh":"滴定法","methodology_zh":"酸值","test_object_zh":"润滑材料：发动机油、工业润滑油"},{"_id":"6a836fb9af14b9c0e7b1eca4","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiały smarne: oleje silnikowe, przemysłowe oleje smarowe","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(0,5 – 8,0)"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Barwa\nZakres (0,5 – 8,0)\nMetoda wizualna","reference":"ASTM D 1500-24","norm_bases":["ASTM D 1500-24"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały smarne: oleje silnikowe, przemysłowe oleje smarowe Barwa\nZakres (0,5 – 8,0)\nMetoda wizualna ASTM D 1500-24 Materialy smarne: oleje silnikowe, przemyslowe oleje smarowe Barwa\nZakres (0,5 – 8,0)\nMetoda wizualna ASTM D 1500-24","categories":["materials","petro"],"row_index":397,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"(0,5 – 8,0)"}],"search_en":"Lubricants: engine oils, industrial lubricating oils Colour Visual method Range ASTM D 1500-24","technique_en":"Visual method","test_object_en":"Lubricants: engine oils, industrial lubricating oils","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(0,5 – 8,0)"}],"search_zh":"润滑材料：发动机油、工业润滑油 色度 目视法 范围 ASTM D 1500-24","technique_zh":"目视法","test_object_zh":"润滑材料：发动机油、工业润滑油"},{"_id":"6a836fb9af14b9c0e7b1eca5","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiały smarne: oleje silnikowe, przemysłowe oleje smarowe","methodology":"Zawartość wapnia, fosforu, magnezu, cynku","parameters":[{"name":"Ca","range":"(0,003 – 0,300) %m/m"},{"name":"Mg","range":"(0,003 – 0,300) %m/m"},{"name":"P","range":"(0,003 – 0,300) %m/m"},{"name":"Zn","range":"(0,003 – 0,300) %m/m"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość wapnia, fosforu, magnezu, cynku\nZakres:\nCa (0,003 – 0,300) %m/m\nMg (0,003 – 0,300) %m/m\nP (0,003 – 0,300) %m/m\nZn (0,003 – 0,300) %m/m\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"ASTM D 4951-14(2019)","norm_bases":["ASTM D 4951-14(2019)"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały smarne: oleje silnikowe, przemysłowe oleje smarowe Zawartość wapnia, fosforu, magnezu, cynku\nZakres:\nCa (0,003 – 0,300) %m/m\nMg (0,003 – 0,300) %m/m\nP (0,003 – 0,300) %m/m\nZn (0,003 – 0,300) %m/m\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) ASTM D 4951-14(2019) Materialy smarne: oleje silnikowe, przemyslowe oleje smarowe Zawartosc wapnia, fosforu, magnezu, cynku\nZakres:\nCa (0,003 – 0,300) %m/m\nMg (0,003 – 0,300) %m/m\nP (0,003 – 0,300) %m/m\nZn (0,003 – 0,300) %m/m\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) ASTM D 4951-14(2019)","categories":["materials","petro"],"row_index":398,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of calcium, phosphorus, magnesium, zinc","parameters_en":[{"name":"Ca","range":"(0,003 – 0,300) %m/m"},{"name":"Mg","range":"(0,003 – 0,300) %m/m"},{"name":"P","range":"(0,003 – 0,300) %m/m"},{"name":"Zn","range":"(0,003 – 0,300) %m/m"}],"search_en":"Lubricants: engine oils, industrial lubricating oils Content of calcium, phosphorus, magnesium, zinc Inductively coupled plasma optical emission spectrometry (ICP-OES) Ca Mg P Zn ASTM D 4951-14(2019)","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Lubricants: engine oils, industrial lubricating oils","parameters_zh":[{"name":"Ca","range":"(0,003 – 0,300) %m/m"},{"name":"Mg","range":"(0,003 – 0,300) %m/m"},{"name":"P","range":"(0,003 – 0,300) %m/m"},{"name":"Zn","range":"(0,003 – 0,300) %m/m"}],"search_zh":"润滑材料：发动机油、工业润滑油 电感耦合等离子体原子发射光谱法（ICP-OES） Ca Mg P Zn ASTM D 4951-14(2019)","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"润滑材料：发动机油、工业润滑油"},{"_id":"6a836fb9af14b9c0e7b1eca6","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Inne przetwory naftowe: asfalty, wyroby asfaltowe","methodology":"Temperatura łamliwości","parameters":[{"name":"[(-23)","range":"(-8)] °C"}],"technique":"Metoda Fraassa","techniques":["Metoda Fraassa"],"computed":[],"activity":"Temperatura łamliwości\n[(-23) (-8)] °C\nMetoda Fraassa","reference":"PN-EN 12593:2015-08","norm_bases":["PN-EN 12593:2015-08"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Inne przetwory naftowe: asfalty, wyroby asfaltowe Temperatura łamliwości\n[(-23) (-8)] °C\nMetoda Fraassa PN-EN 12593:2015-08 Inne przetwory naftowe: asfalty, wyroby asfaltowe Temperatura lamliwosci\n[(-23) (-8)] °C\nMetoda Fraassa PN-EN 12593:2015-08","categories":["other"],"row_index":399,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Brittleness temperature","search_en":"Other petroleum products: bitumen, bituminous products Brittleness temperature Fraass method PN-EN 12593:2015-08","technique_en":"Fraass method","test_object_en":"Other petroleum products: bitumen, bituminous products"},{"_id":"6a836fb9af14b9c0e7b1eca7","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Inne przetwory naftowe: asfalty, wyroby asfaltowe","methodology":"Penetracja","parameters":[{"name":"Zakres","range":"(20 – 220) * 0,1mm"}],"technique":"Metoda penetracji igłą","techniques":["Metoda penetracji igłą"],"computed":[],"activity":"Penetracja\nZakres (20 – 220) * 0,1mm\nMetoda penetracji igłą","reference":"PN-EN 1426:2025-02","norm_bases":["PN-EN 1426:2025-02"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Inne przetwory naftowe: asfalty, wyroby asfaltowe Penetracja\nZakres (20 – 220) * 0,1mm\nMetoda penetracji igłą PN-EN 1426:2025-02 Inne przetwory naftowe: asfalty, wyroby asfaltowe Penetracja\nZakres (20 – 220) * 0,1mm\nMetoda penetracji igla PN-EN 1426:2025-02","categories":["other"],"row_index":400,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Penetration","parameters_en":[{"name":"Range","range":"(20 – 220) * 0,1mm"}],"search_en":"Other petroleum products: bitumen, bituminous products Penetration Needle penetration method Range PN-EN 1426:2025-02","technique_en":"Needle penetration method","test_object_en":"Other petroleum products: bitumen, bituminous products","parameters_zh":[{"name":"范围","range":"(20 – 220) * 0,1mm"}],"search_zh":"针入度 针入度法 范围 PN-EN 1426:2025-02","methodology_zh":"针入度","technique_zh":"针入度法"},{"_id":"6a836fb9af14b9c0e7b1eca8","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Inne przetwory naftowe: asfalty, wyroby asfaltowe","methodology":"Temperatura mięknienia asfaltów","parameters":[{"name":"Zakres","range":"(30,0 – 110,0) °C"}],"technique":"Metoda Pierścień i Kula","techniques":["Metoda Pierścień i Kula"],"computed":[],"activity":"Temperatura mięknienia asfaltów\nZakres (30,0 – 110,0) °C\nMetoda Pierścień i Kula","reference":"PN-EN 1427:2015-08","norm_bases":["PN-EN 1427:2015-08"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Inne przetwory naftowe: asfalty, wyroby asfaltowe Temperatura mięknienia asfaltów\nZakres (30,0 – 110,0) °C\nMetoda Pierścień i Kula PN-EN 1427:2015-08 Inne przetwory naftowe: asfalty, wyroby asfaltowe Temperatura mieknienia asfaltow\nZakres (30,0 – 110,0) °C\nMetoda Pierscien i Kula PN-EN 1427:2015-08","categories":["other"],"row_index":401,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Softening point of bitumens","parameters_en":[{"name":"Range","range":"(30,0 – 110,0) °C"}],"search_en":"Other petroleum products: bitumen, bituminous products Softening point of bitumens Ring and Ball method Range PN-EN 1427:2015-08","technique_en":"Ring and Ball method","test_object_en":"Other petroleum products: bitumen, bituminous products","parameters_zh":[{"name":"范围","range":"(30,0 – 110,0) °C"}],"search_zh":"环球法 范围 PN-EN 1427:2015-08","technique_zh":"环球法"},{"_id":"6a836fb9af14b9c0e7b1eca9","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Liczba jodowa","parameters":[{"name":"Zakres","range":"(85 – 130) g jodu/100g"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Liczba jodowa\nZakres (85 – 130) g jodu/100g\nMetoda miareczkowa","reference":"PN-EN 14111:2022-11","norm_bases":["PN-EN 14111:2022-11"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Liczba jodowa\nZakres (85 – 130) g jodu/100g\nMetoda miareczkowa PN-EN 14111:2022-11 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Liczba jodowa\nZakres (85 – 130) g jodu/100g\nMetoda miareczkowa PN-EN 14111:2022-11","categories":["petro"],"row_index":402,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Iodine value","parameters_en":[{"name":"Range","range":"(85 – 130) g jodu/100g"}],"search_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME) Iodine value Titrimetric method Range PN-EN 14111:2022-11","technique_en":"Titrimetric method","test_object_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME)","parameters_zh":[{"name":"范围","range":"(85 – 130) g jodu/100g"}],"search_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME） 碘值 滴定法 范围 PN-EN 14111:2022-11","technique_zh":"滴定法","test_object_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME）","methodology_zh":"碘值"},{"_id":"6a836fb9af14b9c0e7b1ecaa","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Liczba kwasowa","parameters":[{"name":"Zakres","range":"(0,10 – 1,00) mg/g KOH"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Liczba kwasowa\nZakres (0,10 – 1,00) mg/g KOH\nMetoda miareczkowa","reference":"PN-EN 14104:2021-06","norm_bases":["PN-EN 14104:2021-06"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Liczba kwasowa\nZakres (0,10 – 1,00) mg/g KOH\nMetoda miareczkowa PN-EN 14104:2021-06 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Liczba kwasowa\nZakres (0,10 – 1,00) mg/g KOH\nMetoda miareczkowa PN-EN 14104:2021-06","categories":["petro"],"row_index":403,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Acid value","parameters_en":[{"name":"Range","range":"(0,10 – 1,00) mg/g KOH"}],"search_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME) Acid value Titrimetric method Range PN-EN 14104:2021-06","technique_en":"Titrimetric method","test_object_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME)","parameters_zh":[{"name":"范围","range":"(0,10 – 1,00) mg/g KOH"}],"search_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME） 酸值 滴定法 范围 PN-EN 14104:2021-06","technique_zh":"滴定法","methodology_zh":"酸值","test_object_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME）"},{"_id":"6a836fb9af14b9c0e7b1ecab","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Stabilność oksydacyjna","parameters":[{"name":"Zakres","range":"(1,0 – 15,0) h"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Stabilność oksydacyjna\nZakres (1,0 – 15,0) h\nMetoda konduktometryczna","reference":"PN-EN 14112:2021-05","norm_bases":["PN-EN 14112:2021-05"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Stabilność oksydacyjna\nZakres (1,0 – 15,0) h\nMetoda konduktometryczna PN-EN 14112:2021-05 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Stabilnosc oksydacyjna\nZakres (1,0 – 15,0) h\nMetoda konduktometryczna PN-EN 14112:2021-05","categories":["petro"],"row_index":404,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Oxidation stability","parameters_en":[{"name":"Range","range":"(1,0 – 15,0) h"}],"search_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME) Oxidation stability Conductometric method Range PN-EN 14112:2021-05","technique_en":"Conductometric method","test_object_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME)","parameters_zh":[{"name":"范围","range":"(1,0 – 15,0) h"}],"search_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME） 氧化安定性 电导法 范围 PN-EN 14112:2021-05","technique_zh":"电导法","methodology_zh":"氧化安定性","test_object_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME）"},{"_id":"6a836fb9af14b9c0e7b1ecac","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość estrów metylowych kwasów tłuszczowych (FAME )","parameters":[{"name":"Zakres","range":"(90,0 – 99,0) %(m/m)"},{"name":"Zawartość estru metylowego kwasu linolenowego"},{"name":"Zakres","range":"(1,0 – 15,0) % (m/m)"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość estrów metylowych kwasów tłuszczowych (FAME )\nZakres:\nZakres (90,0 – 99,0) %(m/m)\nZawartość estru metylowego kwasu linolenowego\nZakres (1,0 – 15,0) % (m/m)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 14103:2020-06","norm_bases":["PN-EN 14103:2020-06"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Zawartość estrów metylowych kwasów tłuszczowych (FAME )\nZakres:\nZakres (90,0 – 99,0) %(m/m)\nZawartość estru metylowego kwasu linolenowego\nZakres (1,0 – 15,0) % (m/m)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 14103:2020-06 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Zawartosc estrow metylowych kwasow tluszczowych (FAME )\nZakres:\nZakres (90,0 – 99,0) %(m/m)\nZawartosc estru metylowego kwasu linolenowego\nZakres (1,0 – 15,0) % (m/m)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 14103:2020-06","categories":["petro"],"row_index":405,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fatty acid methyl ester (FAME ) content","parameters_en":[{"name":"Range","range":"(90,0 – 99,0) %(m/m)"},{"name":"Linolenic acid methyl ester content"},{"name":"Range","range":"(1,0 – 15,0) % (m/m)"}],"search_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME) Fatty acid methyl ester (FAME ) content Gas chromatography with flame ionization detection (GC-FID) Range Linolenic acid methyl ester content Range PN-EN 14103:2020-06","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME)","parameters_zh":[{"name":"范围","range":"(90,0 – 99,0) %(m/m)"},{"name":"Zawartość estru metylowego kwasu linolenowego"},{"name":"范围","range":"(1,0 – 15,0) % (m/m)"}],"search_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME） 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-EN 14103:2020-06","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME）"},{"_id":"6a836fb9af14b9c0e7b1ecad","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe – estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość wielonienasyconych estrów metylowych kwasów tłuszczowych (powyżej 4 wiązań podwójnych)","parameters":[{"name":"Zakres","range":"(0,6 – 0,8) %(m/m)"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość wielonienasyconych estrów metylowych kwasów tłuszczowych (powyżej 4 wiązań podwójnych)\nZakres (0,6 – 0,8) %(m/m)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 15779+A1:2013-12","norm_bases":["PN-EN 15779+A1:2013-12"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe – estry metylowe kwasów tłuszczowych (FAME) Zawartość wielonienasyconych estrów metylowych kwasów tłuszczowych (powyżej 4 wiązań podwójnych)\nZakres (0,6 – 0,8) %(m/m)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 15779+A1:2013-12 Paliwa ciekle: biopaliwa ciekle – estry metylowe kwasow tluszczowych (FAME) Zawartosc wielonienasyconych estrow metylowych kwasow tluszczowych (powyzej 4 wiazan podwojnych)\nZakres (0,6 – 0,8) %(m/m)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 15779+A1:2013-12","categories":["petro"],"row_index":406,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of polyunsaturated fatty acid methyl esters (more than 4 double bonds)","parameters_en":[{"name":"Range","range":"(0,6 – 0,8) %(m/m)"}],"search_en":"Liquid fuels: liquid biofuels – fatty acid methyl esters (FAME) Content of polyunsaturated fatty acid methyl esters (more than 4 double bonds) Gas chromatography with flame ionization detection (GC-FID) Range PN-EN 15779+A1:2013-12","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Liquid fuels: liquid biofuels – fatty acid methyl esters (FAME)","parameters_zh":[{"name":"范围","range":"(0,6 – 0,8) %(m/m)"}],"search_zh":"液体燃料：液体生物燃料 － 脂肪酸甲酯（FAME） 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-EN 15779+A1:2013-12","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"液体燃料：液体生物燃料 － 脂肪酸甲酯（FAME）"},{"_id":"6a836fb9af14b9c0e7b1ecae","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe – estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość monoacylogliceroli","parameters":[{"name":"Zakres","range":"(0,10 – 1,25) %(m/m)"},{"name":"Zawartość diacylogliceroli"},{"name":"Zakres","range":"(0,10 – 0,50) %(m/m)"},{"name":"Zawartość triacylogliceroli"},{"name":"Zakres","range":"(0,10 – 0,40) %(m/m)"},{"name":"Zawartość wolnego glicerolu"},{"name":"Zakres","range":"(0,001 – 0,050) %(m/m)"},{"name":"Zawartość ogólnego glicerolu (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość monoacylogliceroli\nZakres:\nZakres (0,10 – 1,25) %(m/m)\nZawartość diacylogliceroli\nZakres (0,10 – 0,50) %(m/m)\nZawartość triacylogliceroli\nZakres (0,10 – 0,40) %(m/m)\nZawartość wolnego glicerolu\nZakres (0,001 – 0,050) %(m/m)\nZawartość ogólnego glicerolu (z obliczeń)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 14105:2025-04","norm_bases":["PN-EN 14105:2025-04"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe – estry metylowe kwasów tłuszczowych (FAME) Zawartość monoacylogliceroli\nZakres:\nZakres (0,10 – 1,25) %(m/m)\nZawartość diacylogliceroli\nZakres (0,10 – 0,50) %(m/m)\nZawartość triacylogliceroli\nZakres (0,10 – 0,40) %(m/m)\nZawartość wolnego glicerolu\nZakres (0,001 – 0,050) %(m/m)\nZawartość ogólnego glicerolu (z obliczeń)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 14105:2025-04 Paliwa ciekle: biopaliwa ciekle – estry metylowe kwasow tluszczowych (FAME) Zawartosc monoacylogliceroli\nZakres:\nZakres (0,10 – 1,25) %(m/m)\nZawartosc diacylogliceroli\nZakres (0,10 – 0,50) %(m/m)\nZawartosc triacylogliceroli\nZakres (0,10 – 0,40) %(m/m)\nZawartosc wolnego glicerolu\nZakres (0,001 – 0,050) %(m/m)\nZawartosc ogolnego glicerolu (z obliczen)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 14105:2025-04","categories":["petro"],"row_index":407,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Monoacylglycerol content","parameters_en":[{"name":"Range","range":"(0,10 – 1,25) %(m/m)"},{"name":"Diacylglycerol content"},{"name":"Range","range":"(0,10 – 0,50) %(m/m)"},{"name":"Triacylglycerol content"},{"name":"Range","range":"(0,10 – 0,40) %(m/m)"},{"name":"Free glycerol content"},{"name":"Range","range":"(0,001 – 0,050) %(m/m)"},{"name":"Total glycerol content (calculated)"}],"search_en":"Liquid fuels: liquid biofuels – fatty acid methyl esters (FAME) Monoacylglycerol content Gas chromatography with flame ionization detection (GC-FID) Range Diacylglycerol content Range Triacylglycerol content Range Free glycerol content Range Total glycerol content (calculated) PN-EN 14105:2025-04","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Liquid fuels: liquid biofuels – fatty acid methyl esters (FAME)","parameters_zh":[{"name":"范围","range":"(0,10 – 1,25) %(m/m)"},{"name":"Zawartość diacylogliceroli"},{"name":"范围","range":"(0,10 – 0,50) %(m/m)"},{"name":"Zawartość triacylogliceroli"},{"name":"范围","range":"(0,10 – 0,40) %(m/m)"},{"name":"Zawartość wolnego glicerolu"},{"name":"范围","range":"(0,001 – 0,050) %(m/m)"},{"name":"Zawartość ogólnego glicerolu (z obliczeń)"}],"search_zh":"液体燃料：液体生物燃料 － 脂肪酸甲酯（FAME） 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 范围 范围 PN-EN 14105:2025-04","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"液体燃料：液体生物燃料 － 脂肪酸甲酯（FAME）"},{"_id":"6a836fb9af14b9c0e7b1ecaf","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe – estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość alkoholu metylowego","parameters":[{"name":"Zakres","range":"(0,01 – 0,10) %(m/m)"}],"technique":"Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID)","techniques":["Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID)"],"computed":[],"activity":"Zawartość alkoholu metylowego\nZakres (0,01 – 0,10) %(m/m)\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID)","reference":"PN-EN 14110:2019-05 z wyłączeniem procedury A","norm_bases":["PN-EN 14110:2019-05 z wyłączeniem procedury A"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe – estry metylowe kwasów tłuszczowych (FAME) Zawartość alkoholu metylowego\nZakres (0,01 – 0,10) %(m/m)\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID) PN-EN 14110:2019-05 z wyłączeniem procedury A Paliwa ciekle: biopaliwa ciekle – estry metylowe kwasow tluszczowych (FAME) Zawartosc alkoholu metylowego\nZakres (0,01 – 0,10) %(m/m)\nMetoda chromatografii gazowej z analiza fazy nadpowierzchniowej i detekcja plomieniowo-jonizacyjna (HS-GC-FID) PN-EN 14110:2019-05 z wylaczeniem procedury A","categories":["petro"],"row_index":408,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Methyl alcohol content","parameters_en":[{"name":"Range","range":"(0,01 – 0,10) %(m/m)"}],"search_en":"Liquid fuels: liquid biofuels – fatty acid methyl esters (FAME) Methyl alcohol content Headspace gas chromatography with flame ionization detection (HS-GC-FID) Range PN-EN 14110:2019-05 z wyłączeniem procedury A","technique_en":"Headspace gas chromatography with flame ionization detection (HS-GC-FID)","test_object_en":"Liquid fuels: liquid biofuels – fatty acid methyl esters (FAME)","parameters_zh":[{"name":"范围","range":"(0,01 – 0,10) %(m/m)"}],"search_zh":"液体燃料：液体生物燃料 － 脂肪酸甲酯（FAME） 甲醇含量 顶空气相色谱-火焰离子化检测法（HS-GC-FID） 范围 PN-EN 14110:2019-05 z wyłączeniem procedury A","technique_zh":"顶空气相色谱-火焰离子化检测法（HS-GC-FID）","test_object_zh":"液体燃料：液体生物燃料 － 脂肪酸甲酯（FAME）","methodology_zh":"甲醇含量"},{"_id":"6a836fb9af14b9c0e7b1ecb0","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe – estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość fosforu","parameters":[{"name":"Zakres","range":"(4,0 – 10,0) mg/kg"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość fosforu\nZakres (4,0 – 10,0) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN 14107:2004","norm_bases":["PN-EN 14107:2004"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe – estry metylowe kwasów tłuszczowych (FAME) Zawartość fosforu\nZakres (4,0 – 10,0) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN 14107:2004 Paliwa ciekle: biopaliwa ciekle – estry metylowe kwasow tluszczowych (FAME) Zawartosc fosforu\nZakres (4,0 – 10,0) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN 14107:2004","categories":["petro"],"row_index":409,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phosphorus content","parameters_en":[{"name":"Range","range":"(4,0 – 10,0) mg/kg"}],"search_en":"Liquid fuels: liquid biofuels – fatty acid methyl esters (FAME) Phosphorus content Inductively coupled plasma optical emission spectrometry (ICP-OES) Range PN-EN 14107:2004","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Liquid fuels: liquid biofuels – fatty acid methyl esters (FAME)","parameters_zh":[{"name":"范围","range":"(4,0 – 10,0) mg/kg"}],"search_zh":"液体燃料：液体生物燃料 － 脂肪酸甲酯（FAME） 磷含量 电感耦合等离子体原子发射光谱法（ICP-OES） 范围 PN-EN 14107:2004","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","methodology_zh":"磷含量","test_object_zh":"液体燃料：液体生物燃料 － 脂肪酸甲酯（FAME）"},{"_id":"6a836fb9af14b9c0e7b1ecb1","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe – estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość wapnia i magnezu","parameters":[{"name":"Zakres","range":"(1,0 – 10,0) mg/kg"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość wapnia i magnezu\nZakres (1,0 – 10,0) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN 14538:2008","norm_bases":["PN-EN 14538:2008"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe – estry metylowe kwasów tłuszczowych (FAME) Zawartość wapnia i magnezu\nZakres (1,0 – 10,0) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN 14538:2008 Paliwa ciekle: biopaliwa ciekle – estry metylowe kwasow tluszczowych (FAME) Zawartosc wapnia i magnezu\nZakres (1,0 – 10,0) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN 14538:2008","categories":["petro"],"row_index":410,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Calcium and magnesium content","parameters_en":[{"name":"Range","range":"(1,0 – 10,0) mg/kg"}],"search_en":"Liquid fuels: liquid biofuels – fatty acid methyl esters (FAME) Calcium and magnesium content Inductively coupled plasma optical emission spectrometry (ICP-OES) Range PN-EN 14538:2008","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Liquid fuels: liquid biofuels – fatty acid methyl esters (FAME)","parameters_zh":[{"name":"范围","range":"(1,0 – 10,0) mg/kg"}],"search_zh":"液体燃料：液体生物燃料 － 脂肪酸甲酯（FAME） 钙与镁含量 电感耦合等离子体原子发射光谱法（ICP-OES） 范围 PN-EN 14538:2008","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","methodology_zh":"钙与镁含量","test_object_zh":"液体燃料：液体生物燃料 － 脂肪酸甲酯（FAME）"},{"_id":"6a836fb9af14b9c0e7b1ecb2","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe – estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość sodu","parameters":[{"name":"Zakres","range":"(1,0 – 10,0) mg/kg"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość sodu\nZakres (1,0 – 10,0) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN 14538:2008","norm_bases":["PN-EN 14538:2008"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe – estry metylowe kwasów tłuszczowych (FAME) Zawartość sodu\nZakres (1,0 – 10,0) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN 14538:2008 Paliwa ciekle: biopaliwa ciekle – estry metylowe kwasow tluszczowych (FAME) Zawartosc sodu\nZakres (1,0 – 10,0) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN 14538:2008","categories":["petro"],"row_index":411,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sodium content","parameters_en":[{"name":"Range","range":"(1,0 – 10,0) mg/kg"}],"search_en":"Liquid fuels: liquid biofuels – fatty acid methyl esters (FAME) Sodium content Inductively coupled plasma optical emission spectrometry (ICP-OES) Range PN-EN 14538:2008","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Liquid fuels: liquid biofuels – fatty acid methyl esters (FAME)","parameters_zh":[{"name":"范围","range":"(1,0 – 10,0) mg/kg"}],"search_zh":"液体燃料：液体生物燃料 － 脂肪酸甲酯（FAME） 钠含量 电感耦合等离子体原子发射光谱法（ICP-OES） 范围 PN-EN 14538:2008","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","methodology_zh":"钠含量","test_object_zh":"液体燃料：液体生物燃料 － 脂肪酸甲酯（FAME）"},{"_id":"6a836fb9af14b9c0e7b1ecb3","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe – estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość potasu","parameters":[{"name":"Zakres","range":"(1,0 – 10,0) mg/kg"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość potasu\nZakres (1,0 – 10,0) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN 14538:2008","norm_bases":["PN-EN 14538:2008"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe – estry metylowe kwasów tłuszczowych (FAME) Zawartość potasu\nZakres (1,0 – 10,0) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN 14538:2008 Paliwa ciekle: biopaliwa ciekle – estry metylowe kwasow tluszczowych (FAME) Zawartosc potasu\nZakres (1,0 – 10,0) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN 14538:2008","categories":["petro"],"row_index":412,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Potassium content","parameters_en":[{"name":"Range","range":"(1,0 – 10,0) mg/kg"}],"search_en":"Liquid fuels: liquid biofuels – fatty acid methyl esters (FAME) Potassium content Inductively coupled plasma optical emission spectrometry (ICP-OES) Range PN-EN 14538:2008","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Liquid fuels: liquid biofuels – fatty acid methyl esters (FAME)","parameters_zh":[{"name":"范围","range":"(1,0 – 10,0) mg/kg"}],"search_zh":"液体燃料：液体生物燃料 － 脂肪酸甲酯（FAME） 钾含量 电感耦合等离子体原子发射光谱法（ICP-OES） 范围 PN-EN 14538:2008","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","methodology_zh":"钾含量","test_object_zh":"液体燃料：液体生物燃料 － 脂肪酸甲酯（FAME）"},{"_id":"6a836fb9af14b9c0e7b1ecb4","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe – estry metylowe kwasów tłuszczowych (FAME)","methodology":"Skłonność biodiesla do blokowania filtra paliwa","parameters":[{"name":"Zakres","range":"(80 – 400) s"}],"technique":"Metoda CSFT","techniques":["Metoda CSFT"],"computed":[],"activity":"Skłonność biodiesla do blokowania filtra paliwa\nZakres (80 – 400) s\nMetoda CSFT","reference":"ASTM D 7501-22","norm_bases":["ASTM D 7501-22"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe – estry metylowe kwasów tłuszczowych (FAME) Skłonność biodiesla do blokowania filtra paliwa\nZakres (80 – 400) s\nMetoda CSFT ASTM D 7501-22 Paliwa ciekle: biopaliwa ciekle – estry metylowe kwasow tluszczowych (FAME) Sklonnosc biodiesla do blokowania filtra paliwa\nZakres (80 – 400) s\nMetoda CSFT ASTM D 7501-22","categories":["petro"],"row_index":413,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Tendency of biodiesel to block the fuel filter","parameters_en":[{"name":"Range","range":"(80 – 400) s"}],"search_en":"Liquid fuels: liquid biofuels – fatty acid methyl esters (FAME) Tendency of biodiesel to block the fuel filter CSFT method Range ASTM D 7501-22","technique_en":"CSFT method","test_object_en":"Liquid fuels: liquid biofuels – fatty acid methyl esters (FAME)","parameters_zh":[{"name":"范围","range":"(80 – 400) s"}],"search_zh":"液体燃料：液体生物燃料 － 脂肪酸甲酯（FAME） 范围 ASTM D 7501-22","test_object_zh":"液体燃料：液体生物燃料 － 脂肪酸甲酯（FAME）"},{"_id":"6a836fb9af14b9c0e7b1ecb5","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":"Metoda manualna","techniques":["Metoda manualna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna PN-ISO 5667-10:2021-11 Scieki Pobieranie probek do badan chemicznych i fizycznych\nMetoda manualna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":414,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Wastewater Sampling for chemical and physical testing Manual method PN-ISO 5667-10:2021-11","technique_en":"Manual method","test_object_en":"Wastewater","methodology_zh":"化学与物理检测用样品采集","search_zh":"污水 化学与物理检测用样品采集 手工法 PN-ISO 5667-10:2021-11","test_object_zh":"污水","technique_zh":"手工法"},{"_id":"6a836fb9af14b9c0e7b1ecb6","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,005 – 10,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,005 – 10,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie fosforu ogólnego\nZakres (0,005 – 10,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010 Scieki Stezenie fosforu ogolnego\nZakres (0,005 – 10,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":415,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,005 – 10,0) mg/l"}],"search_en":"Wastewater Total phosphorus concentration Spectrophotometric method Range PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,005 – 10,0) mg/l"}],"search_zh":"污水 总磷浓度 分光光度法 范围 PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a836fb9af14b9c0e7b1ecb7","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(1 – 100) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (1 – 100) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu Kjeldahla\nZakres (1 – 100) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Scieki Stezenie azotu Kjeldahla\nZakres (1 – 100) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":416,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(1 – 100) mg/l"}],"search_en":"Wastewater Kjeldahl nitrogen concentration Titrimetric method Range PN-EN 25663:2001","technique_en":"Titrimetric method","test_object_en":"Wastewater","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(1 – 100) mg/l"}],"search_zh":"污水 凯氏氮浓度 滴定法 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"污水"},{"_id":"6a836fb9af14b9c0e7b1ecb8","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu azotanowego","parameters":[{"name":"Zakres","range":"(0,010 – 30,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotanowego\nZakres (0,010 – 30,0) mg/l\nMetoda spektrofotometryczna","reference":"Metoda 125 Wydanie 2 z dnia 16.07.2020","norm_bases":["Metoda 125 Wydanie 2 z dnia 16.07.2020"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu azotanowego\nZakres (0,010 – 30,0) mg/l\nMetoda spektrofotometryczna Metoda 125 Wydanie 2 z dnia 16.07.2020 Scieki Stezenie azotu azotanowego\nZakres (0,010 – 30,0) mg/l\nMetoda spektrofotometryczna Metoda 125 Wydanie 2 z dnia 16.07.2020","categories":["water"],"row_index":417,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,010 – 30,0) mg/l"}],"search_en":"Wastewater Nitrate nitrogen concentration Spectrophotometric method Range Metoda 125 Wydanie 2 z dnia 16.07.2020","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,010 – 30,0) mg/l"}],"search_zh":"污水 硝态氮浓度 分光光度法 范围 Metoda 125 Wydanie 2 z dnia 16.07.2020","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a836fb9af14b9c0e7b1ecb9","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,005 – 2,5) mg/l"},{"name":"Stężenie azotynów (z obliczeń)"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres:\nZakres (0,005 – 2,5) mg/l\nStężenie azotynów (z obliczeń)\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu azotynowego\nZakres:\nZakres (0,005 – 2,5) mg/l\nStężenie azotynów (z obliczeń)\nMetoda spektrofotometryczna PN-EN 26777:1999 Scieki Stezenie azotu azotynowego\nZakres:\nZakres (0,005 – 2,5) mg/l\nStezenie azotynow (z obliczen)\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":418,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,005 – 2,5) mg/l"},{"name":"Nitrite concentration (calculated)"}],"search_en":"Wastewater Nitrite nitrogen concentration Spectrophotometric method Range Nitrite concentration (calculated) PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,005 – 2,5) mg/l"},{"name":"亚硝酸盐浓度（由计算得出）"}],"search_zh":"污水 亚硝态氮浓度 分光光度法 范围 亚硝酸盐浓度（由计算得出） PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a836fb9af14b9c0e7b1ecba","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu ogólnego (suma azotu Kjeldahla, azotu azotanowego i azotynowego) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu ogólnego (suma azotu Kjeldahla, azotu azotanowego i azotynowego) (z obliczeń)","reference":"Metoda 047 Wydanie 5 z dnia 19.11.2019","norm_bases":["Metoda 047 Wydanie 5 z dnia 19.11.2019"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu ogólnego (suma azotu Kjeldahla, azotu azotanowego i azotynowego) (z obliczeń) Metoda 047 Wydanie 5 z dnia 19.11.2019 Scieki Stezenie azotu ogolnego (suma azotu Kjeldahla, azotu azotanowego i azotynowego) (z obliczen) Metoda 047 Wydanie 5 z dnia 19.11.2019","categories":["water"],"row_index":419,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total nitrogen concentration (sum of Kjeldahl nitrogen, nitrate and nitrite nitrogen) (calculated)","search_en":"Wastewater Total nitrogen concentration (sum of Kjeldahl nitrogen, nitrate and nitrite nitrogen) (calculated) Metoda 047 Wydanie 5 z dnia 19.11.2019","test_object_en":"Wastewater","search_zh":"污水 Metoda 047 Wydanie 5 z dnia 19.11.2019","test_object_zh":"污水"},{"_id":"6a836fb9af14b9c0e7b1ecbb","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"Chemiczne zapotrzebowanie tlenu","parameters":[{"name":"Zakres","range":"(20,0 – 1000) mg O2/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu\nZakres (20,0 – 1000) mg O2/l\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Chemiczne zapotrzebowanie tlenu\nZakres (20,0 – 1000) mg O2/l\nMetoda spektrofotometryczna PN-ISO 15705:2005 Scieki Chemiczne zapotrzebowanie tlenu\nZakres (20,0 – 1000) mg O2/l\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":420,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand","parameters_en":[{"name":"Range","range":"(20,0 – 1000) mg O2/l"}],"search_en":"Wastewater Chemical oxygen demand Spectrophotometric method Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(20,0 – 1000) mg O2/l"}],"search_zh":"污水 化学需氧量（COD） 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"污水","methodology_zh":"化学需氧量（COD）"},{"_id":"6a836fb9af14b9c0e7b1ecbc","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(5,0 – 50) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (5,0 – 50) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Zawiesiny ogólne\nZakres (5,0 – 50) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Scieki, woda Zawiesiny ogolne\nZakres (5,0 – 50) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":421,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(5,0 – 50) mg/l"}],"search_en":"Wastewater, water Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Wastewater, water","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(5,0 – 50) mg/l"}],"search_zh":"废水、水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"废水、水"},{"_id":"6a836fb9af14b9c0e7b1ecbd","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: wodór (automotive)","methodology":"Oznaczanie zawartości wody","parameters":[{"name":"Zakres","range":"(1,00 -10,00) μmol/mol"}],"technique":"Metoda spektrometrii strat we wnęce optycznej z falą ciągłą (CRDS)","techniques":["Metoda spektrometrii strat we wnęce optycznej z falą ciągłą (CRDS)"],"computed":[],"activity":"Oznaczanie zawartości wody\nZakres (1,00 -10,00) μmol/mol\nMetoda spektrometrii strat we wnęce optycznej z falą ciągłą (CRDS)","reference":"NPL Report AS64:2011-08 p. 4.2.1 (a) | Instrukcja IT-M/PP6/95 wydanie 2 z dnia 11.03.2024","norm_bases":["NPL Report AS64:2011-08 p. 4.2.1 (a)","Instrukcja IT-M/PP6/95 wydanie 2 z dnia 11.03.2024"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: wodór (automotive) Oznaczanie zawartości wody\nZakres (1,00 -10,00) μmol/mol\nMetoda spektrometrii strat we wnęce optycznej z falą ciągłą (CRDS) NPL Report AS64:2011-08 p. 4.2.1 (a) | Instrukcja IT-M/PP6/95 wydanie 2 z dnia 11.03.2024 Paliwa gazowe: wodor (automotive) Oznaczanie zawartosci wody\nZakres (1,00 -10,00) μmol/mol\nMetoda spektrometrii strat we wnece optycznej z fala ciagla (CRDS) NPL Report AS64:2011-08 p. 4.2.1 (a) | Instrukcja IT-M/PP6/95 wydanie 2 z dnia 11.03.2024","categories":["water","petro","automotive"],"row_index":422,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Determination of water content","parameters_en":[{"name":"Range","range":"(1,00 -10,00) μmol/mol"}],"search_en":"Gaseous fuels: hydrogen (automotive) Determination of water content Continuous-wave cavity ring-down spectrometry (CRDS) Range NPL Report AS64:2011-08 p. 4.2.1 (a) | Instrukcja IT-M/PP6/95 wydanie 2 z dnia 11.03.2024","technique_en":"Continuous-wave cavity ring-down spectrometry (CRDS)","test_object_en":"Gaseous fuels: hydrogen (automotive)","parameters_zh":[{"name":"范围","range":"(1,00 -10,00) μmol/mol"}],"search_zh":"气体燃料：氢（车用） 范围 NPL Report AS64:2011-08 p. 4.2.1 (a) | Instrukcja IT-M/PP6/95 wydanie 2 z dnia 11.03.2024","test_object_zh":"气体燃料：氢（车用）"},{"_id":"6a836fb9af14b9c0e7b1ecbe","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: wodór (automotive)","methodology":"Zawartość siarkowodoru, siarczku karbonylu, merkaptanu metylowego, disiarczuk węgla","parameters":[{"name":"Siarkowodór","range":"(0,003 – 0,010) μmol/mol"},{"name":"Siarczek karbonylu","range":"(0,003 – 0,010)"},{"name":"μmol/mol Merkaptan metylowy","range":"(0,003 – 0,010)"},{"name":"μmol/mol Disiarczek węgla","range":"(0,003 – 0,010)"},{"name":"Związki siarki ogółem (z obliczeń)"}],"technique":"Metodą chromatografii gazowej z detektorem chemiluminescencyjnym (GC-SCD)","techniques":["Metodą chromatografii gazowej z detektorem chemiluminescencyjnym (GC-SCD)"],"computed":[],"activity":"Zawartość siarkowodoru, siarczku karbonylu, merkaptanu metylowego, disiarczuk węgla\nZakres:\nSiarkowodór (0,003 – 0,010) μmol/mol\nSiarczek karbonylu (0,003 – 0,010)\nμmol/mol Merkaptan metylowy (0,003 – 0,010)\nμmol/mol Disiarczek węgla (0,003 – 0,010)\nZwiązki siarki ogółem (z obliczeń)\nMetodą chromatografii gazowej z detektorem chemiluminescencyjnym (GC-SCD)","reference":"ASTM D 7652-11","norm_bases":["ASTM D 7652-11"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: wodór (automotive) Zawartość siarkowodoru, siarczku karbonylu, merkaptanu metylowego, disiarczuk węgla\nZakres:\nSiarkowodór (0,003 – 0,010) μmol/mol\nSiarczek karbonylu (0,003 – 0,010)\nμmol/mol Merkaptan metylowy (0,003 – 0,010)\nμmol/mol Disiarczek węgla (0,003 – 0,010)\nZwiązki siarki ogółem (z obliczeń)\nMetodą chromatografii gazowej z detektorem chemiluminescencyjnym (GC-SCD) ASTM D 7652-11 Paliwa gazowe: wodor (automotive) Zawartosc siarkowodoru, siarczku karbonylu, merkaptanu metylowego, disiarczuk wegla\nZakres:\nSiarkowodor (0,003 – 0,010) μmol/mol\nSiarczek karbonylu (0,003 – 0,010)\nμmol/mol Merkaptan metylowy (0,003 – 0,010)\nμmol/mol Disiarczek wegla (0,003 – 0,010)\nZwiazki siarki ogolem (z obliczen)\nMetoda chromatografii gazowej z detektorem chemiluminescencyjnym (GC-SCD) ASTM D 7652-11","categories":["petro","automotive"],"row_index":423,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of hydrogen sulphide, carbonyl sulphide, methyl mercaptan, carbon disulphide","parameters_en":[{"name":"Hydrogen sulfide","range":"(0,003 – 0,010) μmol/mol"},{"name":"Carbonyl sulfide","range":"(0,003 – 0,010)"},{"name":"μmol/mol Methyl mercaptan","range":"(0,003 – 0,010)"},{"name":"μmol/mol Carbon disulfide","range":"(0,003 – 0,010)"},{"name":"Total sulfur compounds (calculated)"}],"search_en":"Gaseous fuels: hydrogen (automotive) Content of hydrogen sulphide, carbonyl sulphide, methyl mercaptan, carbon disulphide By gas chromatography with a chemiluminescence detector (GC-SCD) Hydrogen sulfide Carbonyl sulfide μmol/mol Methyl mercaptan μmol/mol Carbon disulfide Total sulfur compounds (calculated) ASTM D 7652-11","technique_en":"By gas chromatography with a chemiluminescence detector (GC-SCD)","test_object_en":"Gaseous fuels: hydrogen (automotive)","search_zh":"气体燃料：氢（车用） 硫化氢 ASTM D 7652-11","test_object_zh":"气体燃料：氢（车用）","parameters_zh":[{"name":"硫化氢","range":"(0,003 – 0,010) μmol/mol"},{"name":"Siarczek karbonylu","range":"(0,003 – 0,010)"},{"name":"μmol/mol Merkaptan metylowy","range":"(0,003 – 0,010)"},{"name":"μmol/mol Disiarczek węgla","range":"(0,003 – 0,010)"},{"name":"Związki siarki ogółem (z obliczeń)"}]},{"_id":"6a836fb9af14b9c0e7b1ecbf","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: wodór (automotive)","methodology":"Zawartość helu","parameters":[{"name":"Hel","range":"(75,0 – 315,0) μmol/mol"},{"name":"Zawartość ditlenku węgla, tlenku węgla, metanu i węglowodorów ogółem z wyłączeniem metanu","range":"(ekwiwalent C1)"},{"name":"Ditlenek węgla","range":"(0,5 – 2,0) μmol/mol"},{"name":"Tlenek węgla","range":"(0,055 – 0,220) μmol/mol"},{"name":"Metan","range":"(30,0 – 100,0) μmol/mol"},{"name":"Węglowodory ogółem z wyłączeniem metanu (ekwiwalent C1)","range":"(0,5 – 2,0)"},{"name":"μmol/mol"}],"technique":"Metoda chromatografii gazowej z detektorem termokonduktometrycznym (GC-TCD); Metoda chromatografii gazowej z detektorem płomieniowo – jonizacyjnym i termokonduktometrycznym (GC-FID/TCD)","techniques":["Metoda chromatografii gazowej z detektorem termokonduktometrycznym (GC-TCD)","Metoda chromatografii gazowej z detektorem płomieniowo – jonizacyjnym i termokonduktometrycznym (GC-FID/TCD)"],"computed":[],"activity":"Zawartość helu\nZakres:\nHel (75,0 – 315,0) μmol/mol\nZawartość ditlenku węgla, tlenku węgla, metanu i węglowodorów ogółem z wyłączeniem metanu (ekwiwalent C1)\nDitlenek węgla (0,5 – 2,0) μmol/mol\nTlenek węgla (0,055 – 0,220) μmol/mol\nMetan (30,0 – 100,0) μmol/mol\nWęglowodory ogółem z wyłączeniem metanu (ekwiwalent C1) (0,5 – 2,0)\nμmol/mol\nMetoda chromatografii gazowej z detektorem termokonduktometrycznym (GC-TCD); Metoda chromatografii gazowej z detektorem płomieniowo – jonizacyjnym i termokonduktometrycznym (GC-FID/TCD)","reference":"NPL Report AS64:2011-08 p.4.2.4 (a) | Instrukcja IT-M/PP6/97 wydanie 3 z dnia 25.03.2024 NPL Report AS64:2011-08 p. 4.2.7 (a), p. 4.2.8 (b), p. 4.2.2 (a) | Instrukcja IT-M/PP6/97 wydanie 3 z dnia 25.03.2024","norm_bases":["NPL Report AS64:2011-08 p.4.2.4 (a)","Instrukcja IT-M/PP6/97 wydanie 3 z dnia 25.03.2024 NPL Report AS64:2011-08 p. 4.2.7 (a), p. 4.2.8 (b), p. 4.2.2 (a)","Instrukcja IT-M/PP6/97 wydanie 3 z dnia 25.03.2024"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: wodór (automotive) Zawartość helu\nZakres:\nHel (75,0 – 315,0) μmol/mol\nZawartość ditlenku węgla, tlenku węgla, metanu i węglowodorów ogółem z wyłączeniem metanu (ekwiwalent C1)\nDitlenek węgla (0,5 – 2,0) μmol/mol\nTlenek węgla (0,055 – 0,220) μmol/mol\nMetan (30,0 – 100,0) μmol/mol\nWęglowodory ogółem z wyłączeniem metanu (ekwiwalent C1) (0,5 – 2,0)\nμmol/mol\nMetoda chromatografii gazowej z detektorem termokonduktometrycznym (GC-TCD); Metoda chromatografii gazowej z detektorem płomieniowo – jonizacyjnym i termokonduktometrycznym (GC-FID/TCD) NPL Report AS64:2011-08 p.4.2.4 (a) | Instrukcja IT-M/PP6/97 wydanie 3 z dnia 25.03.2024 NPL Report AS64:2011-08 p. 4.2.7 (a), p. 4.2.8 (b), p. 4.2.2 (a) | Instrukcja IT-M/PP6/97 wydanie 3 z dnia 25.03.2024 Paliwa gazowe: wodor (automotive) Zawartosc helu\nZakres:\nHel (75,0 – 315,0) μmol/mol\nZawartosc ditlenku wegla, tlenku wegla, metanu i weglowodorow ogolem z wylaczeniem metanu (ekwiwalent C1)\nDitlenek wegla (0,5 – 2,0) μmol/mol\nTlenek wegla (0,055 – 0,220) μmol/mol\nMetan (30,0 – 100,0) μmol/mol\nWeglowodory ogolem z wylaczeniem metanu (ekwiwalent C1) (0,5 – 2,0)\nμmol/mol\nMetoda chromatografii gazowej z detektorem termokonduktometrycznym (GC-TCD); Metoda chromatografii gazowej z detektorem plomieniowo – jonizacyjnym i termokonduktometrycznym (GC-FID/TCD) NPL Report AS64:2011-08 p.4.2.4 (a) | Instrukcja IT-M/PP6/97 wydanie 3 z dnia 25.03.2024 NPL Report AS64:2011-08 p. 4.2.7 (a), p. 4.2.8 (b), p. 4.2.2 (a) | Instrukcja IT-M/PP6/97 wydanie 3 z dnia 25.03.2024","categories":["petro","automotive"],"row_index":424,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Helium content","parameters_en":[{"name":"Helium","range":"(75,0 – 315,0) μmol/mol"},{"name":"Content of carbon dioxide, carbon monoxide, methane and total hydrocarbons excluding methane","range":"(ekwiwalent C1)"},{"name":"Carbon dioxide","range":"(0,5 – 2,0) μmol/mol"},{"name":"Carbon monoxide","range":"(0,055 – 0,220) μmol/mol"},{"name":"Methane","range":"(30,0 – 100,0) μmol/mol"},{"name":"Total hydrocarbons excluding methane (C1 equivalent)","range":"(0,5 – 2,0)"},{"name":"μmol/mol"}],"search_en":"Gaseous fuels: hydrogen (automotive) Helium content Gas chromatography with a thermal conductivity detector (GC-TCD); Gas chromatography with a flame ionization and thermal conductivity detector (GC-FID/TCD) Helium Content of carbon dioxide, carbon monoxide, methane and total hydrocarbons excluding methane Carbon dioxide Carbon monoxide Methane Total hydrocarbons excluding methane (C1 equivalent) μmol/mol NPL Report AS64:2011-08 p.4.2.4 (a) | Instrukcja IT-M/PP6/97 wydanie 3 z dnia 25.03.2024 NPL Report AS64:2011-08 p. 4.2.7 (a), p. 4.2.8 (b), p. 4.2.2 (a) | Instrukcja IT-M/PP6/97 wydanie 3 z dnia 25.03.2024","technique_en":"Gas chromatography with a thermal conductivity detector (GC-TCD); Gas chromatography with a flame ionization and thermal conductivity detector (GC-FID/TCD)","test_object_en":"Gaseous fuels: hydrogen (automotive)","search_zh":"气体燃料：氢（车用） 一氧化碳 甲烷 NPL Report AS64:2011-08 p.4.2.4 (a) | Instrukcja IT-M/PP6/97 wydanie 3 z dnia 25.03.2024 NPL Report AS64:2011-08 p. 4.2.7 (a), p. 4.2.8 (b), p. 4.2.2 (a) | Instrukcja IT-M/PP6/97 wydanie 3 z dnia 25.03.2024","test_object_zh":"气体燃料：氢（车用）","parameters_zh":[{"name":"Hel","range":"(75,0 – 315,0) μmol/mol"},{"name":"Zawartość ditlenku węgla, tlenku węgla, metanu i węglowodorów ogółem z wyłączeniem metanu","range":"(ekwiwalent C1)"},{"name":"Ditlenek węgla","range":"(0,5 – 2,0) μmol/mol"},{"name":"一氧化碳","range":"(0,055 – 0,220) μmol/mol"},{"name":"甲烷","range":"(30,0 – 100,0) μmol/mol"},{"name":"Węglowodory ogółem z wyłączeniem metanu (ekwiwalent C1)","range":"(0,5 – 2,0)"},{"name":"μmol/mol"}]},{"_id":"6a836fb9af14b9c0e7b1ecc0","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: wodór (automotive)","methodology":"Zawartość formaldehydu i halogenków organicznych","parameters":[{"name":"Formaldehyd","range":"(0,05 – 0,40) μmol/mol"},{"name":"Związki halogenowe organiczne:"},{"name":"Zakres","range":"1,2,4-trichlorobenzen (0,002 – 0,04)"},{"name":"μmol/mol 1,2-dichlorobenzen","range":"(0,002 – 0,04)"},{"name":"μmol/mol 1,3-dichlorobenzen","range":"(0,002 – 0,04)"},{"name":"μmol/mol 1,1,2,2-tetrachloroetan","range":"(0,002 - 0,04)"},{"name":"μmol/mol chlorobenzen","range":"(0,002 – 0,04) μmol/mol"},{"name":"tetrachloroetylen","range":"(0,002 – 0,04) μmol/mol"},{"name":"1,2-dibromoetan","range":"(0,002 – 0,04) μmol/mol"},{"name":"1,1,2-trichloroetan","range":"(0,002 – 0,04) μmol/mol"},{"name":"trans-1,3-dichloropropen","range":"(0,002 – 0,04)"},{"name":"μmol/mol 1,3-dichloropropen","range":"(0,002 – 0,04) μmol/mol"},{"name":"trichloroetylen","range":"( 0,002 – 0,04) μmol/mol"},{"name":"1,2-dichloropropan","range":"(0,002 – 0,04) μmol/mol"},{"name":"tetrachlorek węgla","range":"(0,002 – 0,04) μmol/mol"},{"name":"1,1,1-trichloroetan","range":"(0,002 – 0,04) μmol/mol"},{"name":"1,2-dichloroetan","range":"(0,002 – 0,04) μmol/mol"},{"name":"trichlorometan","range":"(0,002 – 0,04) μmol/mol"},{"name":"cis-1,1-dichloroeten","range":"(0,002 – 0,04)"},{"name":"μmol/mol 1,1-dichloroetan","range":"(0,002 – 0,04) μmol/mol"},{"name":"1,1,2-trichloro-1,2,2-trifluorometan","range":"(0,002 – 0,04) μmol/mol"},{"name":"chlorek allilu","range":"(0,002 – 0,04) μmol/mol"},{"name":"chlorek metylenu","range":"(0,002 – 0,04) μmol/mol"},{"name":"1,1-dichloroetan","range":"(0,002 – 0,04) μmol/mol"},{"name":"trichloromonofluorometan","range":"(0,002 – 0,04)"},{"name":"μmol/mol chlorek etylu","range":"(0,002 – 0,04) μmol/mol"},{"name":"bromometan","range":"(0,002 – 0,04) μmol/mol"},{"name":"chloroeten","range":"(0,002 – 0,04) μmol/mol"},{"name":"1,2-dichloro-1,1,1,2-tetrafluoroetan","range":"(0,002 – 0,04) μmol/mol"},{"name":"chlorometan","range":"(0,002 – 0,04) μmol/mol"},{"name":"dichlorodifluorometan","range":"(0,002 – 0,04)"},{"name":"μmol/mol Zawartość związków halogenowych organicznych (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas mas (GC-MS)"],"computed":[],"activity":"Zawartość formaldehydu i halogenków organicznych\nZakres:\nFormaldehyd (0,05 – 0,40) μmol/mol\nZwiązki halogenowe organiczne:\nZakres 1,2,4-trichlorobenzen (0,002 – 0,04)\nμmol/mol 1,2-dichlorobenzen (0,002 – 0,04)\nμmol/mol 1,3-dichlorobenzen (0,002 – 0,04)\nμmol/mol 1,1,2,2-tetrachloroetan (0,002 - 0,04)\nμmol/mol chlorobenzen (0,002 – 0,04) μmol/mol\ntetrachloroetylen (0,002 – 0,04) μmol/mol\n1,2-dibromoetan (0,002 – 0,04) μmol/mol\n1,1,2-trichloroetan (0,002 – 0,04) μmol/mol\ntrans-1,3-dichloropropen (0,002 – 0,04)\nμmol/mol 1,3-dichloropropen (0,002 – 0,04) μmol/mol\ntrichloroetylen ( 0,002 – 0,04) μmol/mol\n1,2-dichloropropan (0,002 – 0,04) μmol/mol\ntetrachlorek węgla (0,002 – 0,04) μmol/mol\n1,1,1-trichloroetan (0,002 – 0,04) μmol/mol\n1,2-dichloroetan (0,002 – 0,04) μmol/mol\ntrichlorometan (0,002 – 0,04) μmol/mol\ncis-1,1-dichloroeten (0,002 – 0,04)\nμmol/mol 1,1-dichloroetan (0,002 – 0,04) μmol/mol\n1,1,2-trichloro-1,2,2-trifluorometan (0,002 – 0,04) μmol/mol\nchlorek allilu (0,002 – 0,04) μmol/mol\nchlorek metylenu (0,002 – 0,04) μmol/mol\n1,1-dichloroetan (0,002 – 0,04) μmol/mol\ntrichloromonofluorometan (0,002 – 0,04)\nμmol/mol chlorek etylu (0,002 – 0,04) μmol/mol\nbromometan (0,002 – 0,04) μmol/mol\nchloroeten (0,002 – 0,04) μmol/mol\n1,2-dichloro-1,1,1,2-tetrafluoroetan (0,002 – 0,04) μmol/mol\nchlorometan (0,002 – 0,04) μmol/mol\ndichlorodifluorometan (0,002 – 0,04)\nμmol/mol Zawartość związków halogenowych organicznych (z obliczeń)\nMetoda chromatografii gazowej z detekcją spektrometrią mas mas (GC-MS)","reference":"ASTM D 7892-25","norm_bases":["ASTM D 7892-25"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: wodór (automotive) Zawartość formaldehydu i halogenków organicznych\nZakres:\nFormaldehyd (0,05 – 0,40) μmol/mol\nZwiązki halogenowe organiczne:\nZakres 1,2,4-trichlorobenzen (0,002 – 0,04)\nμmol/mol 1,2-dichlorobenzen (0,002 – 0,04)\nμmol/mol 1,3-dichlorobenzen (0,002 – 0,04)\nμmol/mol 1,1,2,2-tetrachloroetan (0,002 - 0,04)\nμmol/mol chlorobenzen (0,002 – 0,04) μmol/mol\ntetrachloroetylen (0,002 – 0,04) μmol/mol\n1,2-dibromoetan (0,002 – 0,04) μmol/mol\n1,1,2-trichloroetan (0,002 – 0,04) μmol/mol\ntrans-1,3-dichloropropen (0,002 – 0,04)\nμmol/mol 1,3-dichloropropen (0,002 – 0,04) μmol/mol\ntrichloroetylen ( 0,002 – 0,04) μmol/mol\n1,2-dichloropropan (0,002 – 0,04) μmol/mol\ntetrachlorek węgla (0,002 – 0,04) μmol/mol\n1,1,1-trichloroetan (0,002 – 0,04) μmol/mol\n1,2-dichloroetan (0,002 – 0,04) μmol/mol\ntrichlorometan (0,002 – 0,04) μmol/mol\ncis-1,1-dichloroeten (0,002 – 0,04)\nμmol/mol 1,1-dichloroetan (0,002 – 0,04) μmol/mol\n1,1,2-trichloro-1,2,2-trifluorometan (0,002 – 0,04) μmol/mol\nchlorek allilu (0,002 – 0,04) μmol/mol\nchlorek metylenu (0,002 – 0,04) μmol/mol\n1,1-dichloroetan (0,002 – 0,04) μmol/mol\ntrichloromonofluorometan (0,002 – 0,04)\nμmol/mol chlorek etylu (0,002 – 0,04) μmol/mol\nbromometan (0,002 – 0,04) μmol/mol\nchloroeten (0,002 – 0,04) μmol/mol\n1,2-dichloro-1,1,1,2-tetrafluoroetan (0,002 – 0,04) μmol/mol\nchlorometan (0,002 – 0,04) μmol/mol\ndichlorodifluorometan (0,002 – 0,04)\nμmol/mol Zawartość związków halogenowych organicznych (z obliczeń)\nMetoda chromatografii gazowej z detekcją spektrometrią mas mas (GC-MS) ASTM D 7892-25 Paliwa gazowe: wodor (automotive) Zawartosc formaldehydu i halogenkow organicznych\nZakres:\nFormaldehyd (0,05 – 0,40) μmol/mol\nZwiazki halogenowe organiczne:\nZakres 1,2,4-trichlorobenzen (0,002 – 0,04)\nμmol/mol 1,2-dichlorobenzen (0,002 – 0,04)\nμmol/mol 1,3-dichlorobenzen (0,002 – 0,04)\nμmol/mol 1,1,2,2-tetrachloroetan (0,002 - 0,04)\nμmol/mol chlorobenzen (0,002 – 0,04) μmol/mol\ntetrachloroetylen (0,002 – 0,04) μmol/mol\n1,2-dibromoetan (0,002 – 0,04) μmol/mol\n1,1,2-trichloroetan (0,002 – 0,04) μmol/mol\ntrans-1,3-dichloropropen (0,002 – 0,04)\nμmol/mol 1,3-dichloropropen (0,002 – 0,04) μmol/mol\ntrichloroetylen ( 0,002 – 0,04) μmol/mol\n1,2-dichloropropan (0,002 – 0,04) μmol/mol\ntetrachlorek wegla (0,002 – 0,04) μmol/mol\n1,1,1-trichloroetan (0,002 – 0,04) μmol/mol\n1,2-dichloroetan (0,002 – 0,04) μmol/mol\ntrichlorometan (0,002 – 0,04) μmol/mol\ncis-1,1-dichloroeten (0,002 – 0,04)\nμmol/mol 1,1-dichloroetan (0,002 – 0,04) μmol/mol\n1,1,2-trichloro-1,2,2-trifluorometan (0,002 – 0,04) μmol/mol\nchlorek allilu (0,002 – 0,04) μmol/mol\nchlorek metylenu (0,002 – 0,04) μmol/mol\n1,1-dichloroetan (0,002 – 0,04) μmol/mol\ntrichloromonofluorometan (0,002 – 0,04)\nμmol/mol chlorek etylu (0,002 – 0,04) μmol/mol\nbromometan (0,002 – 0,04) μmol/mol\nchloroeten (0,002 – 0,04) μmol/mol\n1,2-dichloro-1,1,1,2-tetrafluoroetan (0,002 – 0,04) μmol/mol\nchlorometan (0,002 – 0,04) μmol/mol\ndichlorodifluorometan (0,002 – 0,04)\nμmol/mol Zawartosc zwiazkow halogenowych organicznych (z obliczen)\nMetoda chromatografii gazowej z detekcja spektrometria mas mas (GC-MS) ASTM D 7892-25","categories":["petro","automotive"],"row_index":425,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Formaldehyde and organic halide content","parameters_en":[{"name":"Formaldehyde","range":"(0,05 – 0,40) μmol/mol"},{"name":"Organic halogen compounds:"},{"name":"Range","range":"1,2,4-trichlorobenzen (0,002 – 0,04)"},{"name":"μmol/mol 1,2-dichlorobenzene","range":"(0,002 – 0,04)"},{"name":"μmol/mol 1,3-dichlorobenzene","range":"(0,002 – 0,04)"},{"name":"μmol/mol 1,1,2,2-tetrachloroethane","range":"(0,002 - 0,04)"},{"name":"μmol/mol chlorobenzene","range":"(0,002 – 0,04) μmol/mol"},{"name":"tetrachloroethylene","range":"(0,002 – 0,04) μmol/mol"},{"name":"1,2-dibromoethane","range":"(0,002 – 0,04) μmol/mol"},{"name":"1,1,2-trichloroethane","range":"(0,002 – 0,04) μmol/mol"},{"name":"trans-1,3-dichloropropene","range":"(0,002 – 0,04)"},{"name":"μmol/mol 1,3-dichloropropene","range":"(0,002 – 0,04) μmol/mol"},{"name":"trichloroethylene","range":"( 0,002 – 0,04) μmol/mol"},{"name":"1,2-dichloropropane","range":"(0,002 – 0,04) μmol/mol"},{"name":"carbon tetrachloride","range":"(0,002 – 0,04) μmol/mol"},{"name":"1,1,1-trichloroethane","range":"(0,002 – 0,04) μmol/mol"},{"name":"1,2-dichloroethane","range":"(0,002 – 0,04) μmol/mol"},{"name":"trichloromethane","range":"(0,002 – 0,04) μmol/mol"},{"name":"cis-1,1-dichloroethene","range":"(0,002 – 0,04)"},{"name":"μmol/mol 1,1-dichloroethane","range":"(0,002 – 0,04) μmol/mol"},{"name":"1,1,2-trichloro-1,2,2-trifluoromethane","range":"(0,002 – 0,04) μmol/mol"},{"name":"allyl chloride","range":"(0,002 – 0,04) μmol/mol"},{"name":"methylene chloride","range":"(0,002 – 0,04) μmol/mol"},{"name":"1,1-dichloroethane","range":"(0,002 – 0,04) μmol/mol"},{"name":"trichloromonofluoromethane","range":"(0,002 – 0,04)"},{"name":"μmol/mol ethyl chloride","range":"(0,002 – 0,04) μmol/mol"},{"name":"bromomethane","range":"(0,002 – 0,04) μmol/mol"},{"name":"chloroethene","range":"(0,002 – 0,04) μmol/mol"},{"name":"1,2-dichloro-1,1,1,2-tetrafluoroethane","range":"(0,002 – 0,04) μmol/mol"},{"name":"chloromethane","range":"(0,002 – 0,04) μmol/mol"},{"name":"dichlorodifluoromethane","range":"(0,002 – 0,04)"},{"name":"μmol/mol Content of organic halogen compounds (calculated)"}],"search_en":"Gaseous fuels: hydrogen (automotive) Formaldehyde and organic halide content Gas chromatography with mass spectrometry detection (GC-MS) Formaldehyde Organic halogen compounds: Range μmol/mol 1,2-dichlorobenzene μmol/mol 1,3-dichlorobenzene μmol/mol 1,1,2,2-tetrachloroethane μmol/mol chlorobenzene tetrachloroethylene 1,2-dibromoethane 1,1,2-trichloroethane trans-1,3-dichloropropene μmol/mol 1,3-dichloropropene trichloroethylene 1,2-dichloropropane carbon tetrachloride 1,1,1-trichloroethane 1,2-dichloroethane trichloromethane cis-1,1-dichloroethene μmol/mol 1,1-dichloroethane 1,1,2-trichloro-1,2,2-trifluoromethane allyl chloride methylene chloride 1,1-dichloroethane trichloromonofluoromethane μmol/mol ethyl chloride bromomethane chloroethene 1,2-dichloro-1,1,1,2-tetrafluoroethane chloromethane dichlorodifluoromethane μmol/mol Content of organic halogen compounds (calculated) ASTM D 7892-25","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","test_object_en":"Gaseous fuels: hydrogen (automotive)","parameters_zh":[{"name":"Formaldehyd","range":"(0,05 – 0,40) μmol/mol"},{"name":"Związki halogenowe organiczne:"},{"name":"范围","range":"1,2,4-trichlorobenzen (0,002 – 0,04)"},{"name":"μmol/mol 1,2-dichlorobenzen","range":"(0,002 – 0,04)"},{"name":"μmol/mol 1,3-dichlorobenzen","range":"(0,002 – 0,04)"},{"name":"μmol/mol 1,1,2,2-tetrachloroetan","range":"(0,002 - 0,04)"},{"name":"μmol/mol chlorobenzen","range":"(0,002 – 0,04) μmol/mol"},{"name":"四氯乙烯","range":"(0,002 – 0,04) μmol/mol"},{"name":"1,2-二溴乙烷","range":"(0,002 – 0,04) μmol/mol"},{"name":"1,1,2-三氯乙烷","range":"(0,002 – 0,04) μmol/mol"},{"name":"反式-1,3-二氯丙烯","range":"(0,002 – 0,04)"},{"name":"μmol/mol 1,3-dichloropropen","range":"(0,002 – 0,04) μmol/mol"},{"name":"三氯乙烯","range":"( 0,002 – 0,04) μmol/mol"},{"name":"1,2-二氯丙烷","range":"(0,002 – 0,04) μmol/mol"},{"name":"tetrachlorek węgla","range":"(0,002 – 0,04) μmol/mol"},{"name":"1,1,1-三氯乙烷","range":"(0,002 – 0,04) μmol/mol"},{"name":"1,2-二氯乙烷","range":"(0,002 – 0,04) μmol/mol"},{"name":"三氯甲烷","range":"(0,002 – 0,04) μmol/mol"},{"name":"cis-1,1-dichloroeten","range":"(0,002 – 0,04)"},{"name":"μmol/mol 1,1-dichloroetan","range":"(0,002 – 0,04) μmol/mol"},{"name":"1,1,2-trichloro-1,2,2-trifluorometan","range":"(0,002 – 0,04) μmol/mol"},{"name":"chlorek allilu","range":"(0,002 – 0,04) μmol/mol"},{"name":"chlorek metylenu","range":"(0,002 – 0,04) μmol/mol"},{"name":"1,1-二氯乙烷","range":"(0,002 – 0,04) μmol/mol"},{"name":"trichloromonofluorometan","range":"(0,002 – 0,04)"},{"name":"μmol/mol chlorek etylu","range":"(0,002 – 0,04) μmol/mol"},{"name":"溴甲烷","range":"(0,002 – 0,04) μmol/mol"},{"name":"氯乙烯","range":"(0,002 – 0,04) μmol/mol"},{"name":"1,2-dichloro-1,1,1,2-tetrafluoroetan","range":"(0,002 – 0,04) μmol/mol"},{"name":"chlorometan","range":"(0,002 – 0,04) μmol/mol"},{"name":"dichlorodifluorometan","range":"(0,002 – 0,04)"},{"name":"μmol/mol Zawartość związków halogenowych organicznych (z obliczeń)"}],"search_zh":"气体燃料：氢（车用） 范围 四氯乙烯 1,2-二溴乙烷 1,1,2-三氯乙烷 反式-1,3-二氯丙烯 三氯乙烯 1,2-二氯丙烷 1,1,1-三氯乙烷 1,2-二氯乙烷 三氯甲烷 1,1-二氯乙烷 溴甲烷 氯乙烯 ASTM D 7892-25","test_object_zh":"气体燃料：氢（车用）"},{"_id":"6a836fb9af14b9c0e7b1ecc1","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: wodór (automotive)","methodology":"Zawartość argonu, azotu, tlenu","parameters":[{"name":"Argon","range":"(4,0 – 300,0) μmol/mol"},{"name":"Azot","range":"(5,0 – 300,0)μmol/mol"},{"name":"Tlen","range":"(2,0 – 10,0) μmol/mol"}],"technique":"Metoda chromatografii gazowej z detektorem wyładowań helowych (GC-PDHID)","techniques":["Metoda chromatografii gazowej z detektorem wyładowań helowych (GC-PDHID)"],"computed":[],"activity":"Zawartość argonu, azotu, tlenu\nZakres:\nArgon (4,0 – 300,0) μmol/mol\nAzot (5,0 – 300,0)μmol/mol\nTlen (2,0 – 10,0) μmol/mol\nMetoda chromatografii gazowej z detektorem wyładowań helowych (GC-PDHID)","reference":"NPL Report AS64:2011-08 p. 4.2.6 (b), p. 4.2.5 (a), p. 4.2.3 (a) | Instrukcja IT-M/PP6/98 wydanie 3 z dnia 25.03.2024","norm_bases":["NPL Report AS64:2011-08 p. 4.2.6 (b), p. 4.2.5 (a), p. 4.2.3 (a)","Instrukcja IT-M/PP6/98 wydanie 3 z dnia 25.03.2024"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: wodór (automotive) Zawartość argonu, azotu, tlenu\nZakres:\nArgon (4,0 – 300,0) μmol/mol\nAzot (5,0 – 300,0)μmol/mol\nTlen (2,0 – 10,0) μmol/mol\nMetoda chromatografii gazowej z detektorem wyładowań helowych (GC-PDHID) NPL Report AS64:2011-08 p. 4.2.6 (b), p. 4.2.5 (a), p. 4.2.3 (a) | Instrukcja IT-M/PP6/98 wydanie 3 z dnia 25.03.2024 Paliwa gazowe: wodor (automotive) Zawartosc argonu, azotu, tlenu\nZakres:\nArgon (4,0 – 300,0) μmol/mol\nAzot (5,0 – 300,0)μmol/mol\nTlen (2,0 – 10,0) μmol/mol\nMetoda chromatografii gazowej z detektorem wyladowan helowych (GC-PDHID) NPL Report AS64:2011-08 p. 4.2.6 (b), p. 4.2.5 (a), p. 4.2.3 (a) | Instrukcja IT-M/PP6/98 wydanie 3 z dnia 25.03.2024","categories":["petro","automotive"],"row_index":426,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Argon, nitrogen, oxygen content","parameters_en":[{"name":"Argon","range":"(4,0 – 300,0) μmol/mol"},{"name":"Nitrogen","range":"(5,0 – 300,0)μmol/mol"},{"name":"Oxygen","range":"(2,0 – 10,0) μmol/mol"}],"search_en":"Gaseous fuels: hydrogen (automotive) Argon, nitrogen, oxygen content Gas chromatography with a pulsed discharge helium ionization detector (GC-PDHID) Argon Nitrogen Oxygen NPL Report AS64:2011-08 p. 4.2.6 (b), p. 4.2.5 (a), p. 4.2.3 (a) | Instrukcja IT-M/PP6/98 wydanie 3 z dnia 25.03.2024","technique_en":"Gas chromatography with a pulsed discharge helium ionization detector (GC-PDHID)","test_object_en":"Gaseous fuels: hydrogen (automotive)","search_zh":"气体燃料：氢（车用） 氮 氧 NPL Report AS64:2011-08 p. 4.2.6 (b), p. 4.2.5 (a), p. 4.2.3 (a) | Instrukcja IT-M/PP6/98 wydanie 3 z dnia 25.03.2024","test_object_zh":"气体燃料：氢（车用）","parameters_zh":[{"name":"Argon","range":"(4,0 – 300,0) μmol/mol"},{"name":"氮","range":"(5,0 – 300,0)μmol/mol"},{"name":"氧","range":"(2,0 – 10,0) μmol/mol"}]},{"_id":"6a836fb9af14b9c0e7b1ecc2","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: wodór (automotive)","methodology":"Zawartość kwasu mrówkowego, amoniaku","parameters":[{"name":"Kwas mrówkowy","range":"(0,05 – 0,40) μmol/mol"},{"name":"Amoniak","range":"(0,05 – 0,40) μmol/mol"}],"technique":"Metoda chromatografii jonowej z detektorem konduktometrycznym (IC)","techniques":["Metoda chromatografii jonowej z detektorem konduktometrycznym (IC)"],"computed":[],"activity":"Zawartość kwasu mrówkowego, amoniaku\nZakres:\nKwas mrówkowy (0,05 – 0,40) μmol/mol\nAmoniak (0,05 – 0,40) μmol/mol\nMetoda chromatografii jonowej z detektorem konduktometrycznym (IC)","reference":"JIS K0127:2013 | Instrukcja IT-M/PP6/96 wydanie 2 z dnia 11.03.2024","norm_bases":["JIS K0127:2013","Instrukcja IT-M/PP6/96 wydanie 2 z dnia 11.03.2024"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: wodór (automotive) Zawartość kwasu mrówkowego, amoniaku\nZakres:\nKwas mrówkowy (0,05 – 0,40) μmol/mol\nAmoniak (0,05 – 0,40) μmol/mol\nMetoda chromatografii jonowej z detektorem konduktometrycznym (IC) JIS K0127:2013 | Instrukcja IT-M/PP6/96 wydanie 2 z dnia 11.03.2024 Paliwa gazowe: wodor (automotive) Zawartosc kwasu mrowkowego, amoniaku\nZakres:\nKwas mrowkowy (0,05 – 0,40) μmol/mol\nAmoniak (0,05 – 0,40) μmol/mol\nMetoda chromatografii jonowej z detektorem konduktometrycznym (IC) JIS K0127:2013 | Instrukcja IT-M/PP6/96 wydanie 2 z dnia 11.03.2024","categories":["petro","automotive"],"row_index":427,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Formic acid, ammonia content","parameters_en":[{"name":"Formic acid","range":"(0,05 – 0,40) μmol/mol"},{"name":"Ammonia","range":"(0,05 – 0,40) μmol/mol"}],"search_en":"Gaseous fuels: hydrogen (automotive) Formic acid, ammonia content Ion chromatography with a conductometric detector (IC) Formic acid Ammonia JIS K0127:2013 | Instrukcja IT-M/PP6/96 wydanie 2 z dnia 11.03.2024","technique_en":"Ion chromatography with a conductometric detector (IC)","test_object_en":"Gaseous fuels: hydrogen (automotive)","search_zh":"气体燃料：氢（车用） JIS K0127:2013 | Instrukcja IT-M/PP6/96 wydanie 2 z dnia 11.03.2024","test_object_zh":"气体燃料：氢（车用）"},{"_id":"6a836fb9af14b9c0e7b1ecc3","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: wodór (automotive)","methodology":"Zawartość cząstek stałych","parameters":[{"name":"Zakres","range":"(0,15 – 1,40) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość cząstek stałych\nZakres (0,15 – 1,40) mg/kg\nMetoda wagowa","reference":"ASTM D 7651:24e1","norm_bases":["ASTM D 7651:24e1"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: wodór (automotive) Zawartość cząstek stałych\nZakres (0,15 – 1,40) mg/kg\nMetoda wagowa ASTM D 7651:24e1 Paliwa gazowe: wodor (automotive) Zawartosc czastek stalych\nZakres (0,15 – 1,40) mg/kg\nMetoda wagowa ASTM D 7651:24e1","categories":["petro","automotive"],"row_index":428,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Particulate matter content","parameters_en":[{"name":"Range","range":"(0,15 – 1,40) mg/kg"}],"search_en":"Gaseous fuels: hydrogen (automotive) Particulate matter content Gravimetric method Range ASTM D 7651:24e1","technique_en":"Gravimetric method","test_object_en":"Gaseous fuels: hydrogen (automotive)","parameters_zh":[{"name":"范围","range":"(0,15 – 1,40) mg/kg"}],"search_zh":"气体燃料：氢（车用） 重量法 范围 ASTM D 7651:24e1","technique_zh":"重量法","test_object_zh":"气体燃料：氢（车用）"},{"_id":"6a836fb9af14b9c0e7b1ecc4","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: wodór (automotive)","methodology":"Indeks paliwa wodorowego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Indeks paliwa wodorowego (z obliczeń)","reference":"ISO 14687:2019-11","norm_bases":["ISO 14687:2019-11"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: wodór (automotive) Indeks paliwa wodorowego (z obliczeń) ISO 14687:2019-11 Paliwa gazowe: wodor (automotive) Indeks paliwa wodorowego (z obliczen) ISO 14687:2019-11","categories":["petro","automotive"],"row_index":429,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrogen fuel index (calculated)","search_en":"Gaseous fuels: hydrogen (automotive) Hydrogen fuel index (calculated) ISO 14687:2019-11","test_object_en":"Gaseous fuels: hydrogen (automotive)","search_zh":"气体燃料：氢（车用） ISO 14687:2019-11","test_object_zh":"气体燃料：氢（车用）"},{"_id":"6a836fb9af14b9c0e7b1ecc5","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: wodór (automotive)","methodology":"Całkowita zawartość gazów innych niż wodór (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Całkowita zawartość gazów innych niż wodór (z obliczeń)","reference":"ISO 14687:2019-11","norm_bases":["ISO 14687:2019-11"],"lab_section":"Pracownia Produktów Rafineryjnych w Trzebini PP6","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: wodór (automotive) Całkowita zawartość gazów innych niż wodór (z obliczeń) ISO 14687:2019-11 Paliwa gazowe: wodor (automotive) Calkowita zawartosc gazow innych niz wodor (z obliczen) ISO 14687:2019-11","categories":["petro","automotive"],"row_index":430,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total content of gases other than hydrogen (calculated)","search_en":"Gaseous fuels: hydrogen (automotive) Total content of gases other than hydrogen (calculated) ISO 14687:2019-11","test_object_en":"Gaseous fuels: hydrogen (automotive)","search_zh":"气体燃料：氢（车用） ISO 14687:2019-11","test_object_zh":"气体燃料：氢（车用）"},{"_id":"6a836fb9af14b9c0e7b1ecc6","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy","methodology":"Pobieranie próbek z dystrybutora do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek z dystrybutora do badań chemicznych i fizycznych","reference":"PN-EN 14275:2013-06","norm_bases":["PN-EN 14275:2013-06"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy Pobieranie próbek z dystrybutora do badań chemicznych i fizycznych PN-EN 14275:2013-06 Paliwa ciekle: benzyna bezolowiowa, olej napedowy Pobieranie probek z dystrybutora do badan chemicznych i fizycznych PN-EN 14275:2013-06","categories":["petro"],"row_index":431,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling from a dispenser for chemical and physical testing","search_en":"Liquid fuels: unleaded petrol, diesel fuel Sampling from a dispenser for chemical and physical testing PN-EN 14275:2013-06","test_object_en":"Liquid fuels: unleaded petrol, diesel fuel","search_zh":"液体燃料：无铅汽油、柴油 PN-EN 14275:2013-06","test_object_zh":"液体燃料：无铅汽油、柴油"},{"_id":"6a836fb9af14b9c0e7b1ecc7","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej opałowy lekki, olej opałowy ciężki, benzyna bezołowiowa, olej napędowy, Materiały smarne: oleje bazowe, oleje silnikowe, przemysłowe oleje smarowe, Ropa naftowa","methodology":"Pobieranie próbek ze zbiorników do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek ze zbiorników do badań chemicznych i fizycznych","reference":"PN-EN ISO 3170:2025-12 z wyłączeniem 8.3.1.3 - 8.3.1.6, 8.3.1.8, 8.3.2, 8.7, 8.8, 9.8, 10.6, 10.7","norm_bases":["PN-EN ISO 3170:2025-12 z wyłączeniem 8.3.1.3 - 8.3.1.6, 8.3.1.8, 8.3.2, 8.7, 8.8, 9.8, 10.6, 10.7"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej opałowy lekki, olej opałowy ciężki, benzyna bezołowiowa, olej napędowy, Materiały smarne: oleje bazowe, oleje silnikowe, przemysłowe oleje smarowe, Ropa naftowa Pobieranie próbek ze zbiorników do badań chemicznych i fizycznych PN-EN ISO 3170:2025-12 z wyłączeniem 8.3.1.3 - 8.3.1.6, 8.3.1.8, 8.3.2, 8.7, 8.8, 9.8, 10.6, 10.7 Paliwa ciekle: olej opalowy lekki, olej opalowy ciezki, benzyna bezolowiowa, olej napedowy, Materialy smarne: oleje bazowe, oleje silnikowe, przemyslowe oleje smarowe, Ropa naftowa Pobieranie probek ze zbiornikow do badan chemicznych i fizycznych PN-EN ISO 3170:2025-12 z wylaczeniem 8.3.1.3 - 8.3.1.6, 8.3.1.8, 8.3.2, 8.7, 8.8, 9.8, 10.6, 10.7","categories":["petro","materials"],"row_index":432,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling from tanks for chemical and physical testing","search_en":"Liquid fuels: light heating oil, heavy heating oil, unleaded petrol, diesel fuel, Lubricants: base oils, engine oils, industrial lubricating oils, Crude oil Sampling from tanks for chemical and physical testing PN-EN ISO 3170:2025-12 z wyłączeniem 8.3.1.3 - 8.3.1.6, 8.3.1.8, 8.3.2, 8.7, 8.8, 9.8, 10.6, 10.7","test_object_en":"Liquid fuels: light heating oil, heavy heating oil, unleaded petrol, diesel fuel, Lubricants: base oils, engine oils, industrial lubricating oils, Crude oil","methodology_zh":"自储罐采集化学和物理检测样品","search_zh":"自储罐采集化学和物理检测样品 PN-EN ISO 3170:2025-12 z wyłączeniem 8.3.1.3 - 8.3.1.6, 8.3.1.8, 8.3.2, 8.7, 8.8, 9.8, 10.6, 10.7"},{"_id":"6a836fb9af14b9c0e7b1ecc8","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Liczba oktanowa LOM","parameters":[{"name":"Zakres","range":"60 – 100"}],"technique":"Metoda silnikowa","techniques":["Metoda silnikowa"],"computed":[],"activity":"Liczba oktanowa LOM\nZakres 60 – 100\nMetoda silnikowa","reference":"PN-EN ISO 5163:2014-08","norm_bases":["PN-EN ISO 5163:2014-08"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Liczba oktanowa LOM\nZakres 60 – 100\nMetoda silnikowa PN-EN ISO 5163:2014-08 Paliwa ciekle: benzyna bezolowiowa Liczba oktanowa LOM\nZakres 60 – 100\nMetoda silnikowa PN-EN ISO 5163:2014-08","categories":["petro"],"row_index":433,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Motor octane number MON","parameters_en":[{"name":"Range","range":"60 – 100"}],"search_en":"Liquid fuels: unleaded petrol Motor octane number MON Motor method Range PN-EN ISO 5163:2014-08","technique_en":"Motor method","test_object_en":"Liquid fuels: unleaded petrol","parameters_zh":[{"name":"范围","range":"60 – 100"}],"search_zh":"液体燃料：无铅汽油 马达法辛烷值 MON 发动机法 范围 PN-EN ISO 5163:2014-08","technique_zh":"发动机法","test_object_zh":"液体燃料：无铅汽油","methodology_zh":"马达法辛烷值 MON"},{"_id":"6a836fb9af14b9c0e7b1ecc9","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Indeks lotności (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Indeks lotności (z obliczeń)","reference":"PN-EN 228+A1:2017-06 p. 5.5.2","norm_bases":["PN-EN 228+A1:2017-06 p. 5.5.2"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Indeks lotności (z obliczeń) PN-EN 228+A1:2017-06 p. 5.5.2 Paliwa ciekle: benzyna bezolowiowa Indeks lotnosci (z obliczen) PN-EN 228+A1:2017-06 p. 5.5.2","categories":["petro"],"row_index":434,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Volatility index (calculated)","search_en":"Liquid fuels: unleaded petrol Volatility index (calculated) PN-EN 228+A1:2017-06 p. 5.5.2","test_object_en":"Liquid fuels: unleaded petrol","search_zh":"液体燃料：无铅汽油 挥发性指数（计算值） PN-EN 228+A1:2017-06 p. 5.5.2","test_object_zh":"液体燃料：无铅汽油","methodology_zh":"挥发性指数（计算值）"},{"_id":"6a836fb9af14b9c0e7b1ecca","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Prężność par nasyconych powietrzem","parameters":[{"name":"Zakres","range":"(40,0 – 106,0) kPa"}],"technique":"Metoda mini Reid","techniques":["Metoda mini Reid"],"computed":[],"activity":"Prężność par nasyconych powietrzem\nZakres (40,0 – 106,0) kPa\nMetoda mini Reid","reference":"PN-EN 13016-1:2024-11","norm_bases":["PN-EN 13016-1:2024-11"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Prężność par nasyconych powietrzem\nZakres (40,0 – 106,0) kPa\nMetoda mini Reid PN-EN 13016-1:2024-11 Paliwa ciekle: benzyna bezolowiowa Preznosc par nasyconych powietrzem\nZakres (40,0 – 106,0) kPa\nMetoda mini Reid PN-EN 13016-1:2024-11","categories":["petro","environment"],"row_index":435,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air saturated vapour pressure","parameters_en":[{"name":"Range","range":"(40,0 – 106,0) kPa"}],"search_en":"Liquid fuels: unleaded petrol Air saturated vapour pressure Mini Reid method Range PN-EN 13016-1:2024-11","technique_en":"Mini Reid method","test_object_en":"Liquid fuels: unleaded petrol","parameters_zh":[{"name":"范围","range":"(40,0 – 106,0) kPa"}],"search_zh":"液体燃料：无铅汽油 空气饱和蒸气压 迷你雷德法 范围 PN-EN 13016-1:2024-11","test_object_zh":"液体燃料：无铅汽油","technique_zh":"迷你雷德法","methodology_zh":"空气饱和蒸气压"},{"_id":"6a836fb9af14b9c0e7b1eccb","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Zawartość tlenowych związków organicznych","parameters":[{"name":"Zakres","range":"(0,17 – 15,0) % (v/v)"},{"name":"Całkowita zawartość organicznie związanego tlenu (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość tlenowych związków organicznych\nZakres:\nZakres (0,17 – 15,0) % (v/v)\nCałkowita zawartość organicznie związanego tlenu (z obliczeń)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13132:2005","norm_bases":["PN-EN 13132:2005"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Zawartość tlenowych związków organicznych\nZakres:\nZakres (0,17 – 15,0) % (v/v)\nCałkowita zawartość organicznie związanego tlenu (z obliczeń)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13132:2005 Paliwa ciekle: benzyna bezolowiowa Zawartosc tlenowych zwiazkow organicznych\nZakres:\nZakres (0,17 – 15,0) % (v/v)\nCalkowita zawartosc organicznie zwiazanego tlenu (z obliczen)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13132:2005","categories":["petro"],"row_index":436,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of oxygenated organic compounds","parameters_en":[{"name":"Range","range":"(0,17 – 15,0) % (v/v)"},{"name":"Total organically bound oxygen content (calculated)"}],"search_en":"Liquid fuels: unleaded petrol Content of oxygenated organic compounds Gas chromatography with flame ionization detection (GC-FID) Range Total organically bound oxygen content (calculated) PN-EN 13132:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Liquid fuels: unleaded petrol","parameters_zh":[{"name":"范围","range":"(0,17 – 15,0) % (v/v)"},{"name":"有机结合氧总量（由计算得出）"}],"search_zh":"液体燃料：无铅汽油 含氧有机化合物含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 有机结合氧总量（由计算得出） PN-EN 13132:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"液体燃料：无铅汽油","methodology_zh":"含氧有机化合物含量"},{"_id":"6a836fb9af14b9c0e7b1eccc","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki, Wyroby chemiczne: rozpuszczalniki","methodology":"Gęstość","parameters":[{"name":"Zakres","range":"(650,0 – 950,0) kg/m3"}],"technique":"Metoda areometryczna","techniques":["Metoda areometryczna"],"computed":[],"activity":"Gęstość\nZakres (650,0 – 950,0) kg/m3\nMetoda areometryczna","reference":"PN-EN ISO 3675:2004","norm_bases":["PN-EN ISO 3675:2004"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki, Wyroby chemiczne: rozpuszczalniki Gęstość\nZakres (650,0 – 950,0) kg/m3\nMetoda areometryczna PN-EN ISO 3675:2004 Paliwa ciekle: benzyna bezolowiowa, olej napedowy, olej opalowy lekki, Wyroby chemiczne: rozpuszczalniki Gestosc\nZakres (650,0 – 950,0) kg/m3\nMetoda areometryczna PN-EN ISO 3675:2004","categories":["petro"],"row_index":437,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Density","parameters_en":[{"name":"Range","range":"(650,0 – 950,0) kg/m3"}],"search_en":"Liquid fuels: unleaded petrol, diesel fuel, light fuel oil, Chemical products: solvents Density Hydrometer method Range PN-EN ISO 3675:2004","technique_en":"Hydrometer method","test_object_en":"Liquid fuels: unleaded petrol, diesel fuel, light fuel oil, Chemical products: solvents","methodology_zh":"密度","parameters_zh":[{"name":"范围","range":"(650,0 – 950,0) kg/m3"}],"search_zh":"液体燃料：无铅汽油、柴油、轻质燃料油；化工产品：溶剂 密度 比重计法 范围 PN-EN ISO 3675:2004","technique_zh":"比重计法","test_object_zh":"液体燃料：无铅汽油、柴油、轻质燃料油；化工产品：溶剂"},{"_id":"6a836fb9af14b9c0e7b1eccd","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki, Wyroby chemiczne: rozpuszczalniki","methodology":"Gęstość w temperaturze 15°C","parameters":[{"name":"Zakres","range":"(664,0 – 900,0) kg/m3"}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"computed":[],"activity":"Gęstość w temperaturze 15°C\nZakres (664,0 – 900,0) kg/m3\nMetoda oscylacyjna","reference":"PN-EN ISO 12185:2024-08","norm_bases":["PN-EN ISO 12185:2024-08"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki, Wyroby chemiczne: rozpuszczalniki Gęstość w temperaturze 15°C\nZakres (664,0 – 900,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08 Paliwa ciekle: benzyna bezolowiowa, olej napedowy, olej opalowy lekki, Wyroby chemiczne: rozpuszczalniki Gestosc w temperaturze 15°C\nZakres (664,0 – 900,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08","categories":["petro"],"row_index":438,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Density at 15°C","parameters_en":[{"name":"Range","range":"(664,0 – 900,0) kg/m3"}],"search_en":"Liquid fuels: unleaded petrol, diesel fuel, light fuel oil, Chemical products: solvents Density at 15°C Oscillation method Range PN-EN ISO 12185:2024-08","technique_en":"Oscillation method","test_object_en":"Liquid fuels: unleaded petrol, diesel fuel, light fuel oil, Chemical products: solvents","parameters_zh":[{"name":"范围","range":"(664,0 – 900,0) kg/m3"}],"search_zh":"液体燃料：无铅汽油、柴油、轻质燃料油；化工产品：溶剂 15°C 时的密度 振荡法 范围 PN-EN ISO 12185:2024-08","technique_zh":"振荡法","methodology_zh":"15°C 时的密度","test_object_zh":"液体燃料：无铅汽油、柴油、轻质燃料油；化工产品：溶剂"},{"_id":"6a836fb9af14b9c0e7b1ecce","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki, Wyroby chemiczne: rozpuszczalniki","methodology":"Skład frakcyjny","parameters":[{"name":"Zakres","range":"(10,0 – 370,0) °C"}],"technique":"Metoda destylacyjna","techniques":["Metoda destylacyjna"],"computed":[],"activity":"Skład frakcyjny\nZakres (10,0 – 370,0) °C\nMetoda destylacyjna","reference":"PN-EN ISO 3405:2019-05","norm_bases":["PN-EN ISO 3405:2019-05"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki, Wyroby chemiczne: rozpuszczalniki Skład frakcyjny\nZakres (10,0 – 370,0) °C\nMetoda destylacyjna PN-EN ISO 3405:2019-05 Paliwa ciekle: benzyna bezolowiowa, olej napedowy, olej opalowy lekki, Wyroby chemiczne: rozpuszczalniki Sklad frakcyjny\nZakres (10,0 – 370,0) °C\nMetoda destylacyjna PN-EN ISO 3405:2019-05","categories":["petro"],"row_index":439,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fractional composition","parameters_en":[{"name":"Range","range":"(10,0 – 370,0) °C"}],"search_en":"Liquid fuels: unleaded petrol, diesel fuel, light fuel oil, Chemical products: solvents Fractional composition Distillation method Range PN-EN ISO 3405:2019-05","technique_en":"Distillation method","test_object_en":"Liquid fuels: unleaded petrol, diesel fuel, light fuel oil, Chemical products: solvents","parameters_zh":[{"name":"范围","range":"(10,0 – 370,0) °C"}],"search_zh":"液体燃料：无铅汽油、柴油、轻质燃料油；化工产品：溶剂 馏程组成 蒸馏法 范围 PN-EN ISO 3405:2019-05","technique_zh":"蒸馏法","methodology_zh":"馏程组成","test_object_zh":"液体燃料：无铅汽油、柴油、轻质燃料油；化工产品：溶剂"},{"_id":"6a836fb9af14b9c0e7b1eccf","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki, Wyroby chemiczne: rozpuszczalniki","methodology":"Działanie korodujące na miedź","parameters":[{"name":"Zakres","range":"1a – 4c (skala)"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Działanie korodujące na miedź\nZakres 1a – 4c (skala)\nMetoda wizualna","reference":"PN-EN ISO 2160:2004","norm_bases":["PN-EN ISO 2160:2004"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki, Wyroby chemiczne: rozpuszczalniki Działanie korodujące na miedź\nZakres 1a – 4c (skala)\nMetoda wizualna PN-EN ISO 2160:2004 Paliwa ciekle: benzyna bezolowiowa, olej napedowy, olej opalowy lekki, Wyroby chemiczne: rozpuszczalniki Dzialanie korodujace na miedz\nZakres 1a – 4c (skala)\nMetoda wizualna PN-EN ISO 2160:2004","categories":["petro","materials"],"row_index":440,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Copper strip corrosion","parameters_en":[{"name":"Range","range":"1a – 4c (skala)"}],"search_en":"Liquid fuels: unleaded petrol, diesel fuel, light fuel oil, Chemical products: solvents Copper strip corrosion Visual method Range PN-EN ISO 2160:2004","technique_en":"Visual method","test_object_en":"Liquid fuels: unleaded petrol, diesel fuel, light fuel oil, Chemical products: solvents","parameters_zh":[{"name":"范围","range":"1a – 4c (skala)"}],"search_zh":"液体燃料：无铅汽油、柴油、轻质燃料油；化工产品：溶剂 铜片腐蚀 目视法 范围 PN-EN ISO 2160:2004","technique_zh":"目视法","methodology_zh":"铜片腐蚀","test_object_zh":"液体燃料：无铅汽油、柴油、轻质燃料油；化工产品：溶剂"},{"_id":"6a836fb9af14b9c0e7b1ecd0","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki, Wyroby chemiczne: rozpuszczalniki","methodology":"Zawartość siarki","parameters":[{"name":"Zakres","range":"(3 – 500) mg/kg"}],"technique":"Metoda fluorescencji w nadfiolecie","techniques":["Metoda fluorescencji w nadfiolecie"],"computed":[],"activity":"Zawartość siarki\nZakres (3 – 500) mg/kg\nMetoda fluorescencji w nadfiolecie","reference":"PN-EN ISO 20846:2020-03","norm_bases":["PN-EN ISO 20846:2020-03"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki, Wyroby chemiczne: rozpuszczalniki Zawartość siarki\nZakres (3 – 500) mg/kg\nMetoda fluorescencji w nadfiolecie PN-EN ISO 20846:2020-03 Paliwa ciekle: benzyna bezolowiowa, olej napedowy, olej opalowy lekki, Wyroby chemiczne: rozpuszczalniki Zawartosc siarki\nZakres (3 – 500) mg/kg\nMetoda fluorescencji w nadfiolecie PN-EN ISO 20846:2020-03","categories":["petro"],"row_index":441,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfur content","parameters_en":[{"name":"Range","range":"(3 – 500) mg/kg"}],"search_en":"Liquid fuels: unleaded petrol, diesel fuel, light fuel oil, Chemical products: solvents Sulfur content Ultraviolet fluorescence method Range PN-EN ISO 20846:2020-03","technique_en":"Ultraviolet fluorescence method","test_object_en":"Liquid fuels: unleaded petrol, diesel fuel, light fuel oil, Chemical products: solvents","parameters_zh":[{"name":"范围","range":"(3 – 500) mg/kg"}],"search_zh":"液体燃料：无铅汽油、柴油、轻质燃料油；化工产品：溶剂 硫含量 紫外荧光法 范围 PN-EN ISO 20846:2020-03","methodology_zh":"硫含量","technique_zh":"紫外荧光法","test_object_zh":"液体燃料：无铅汽油、柴油、轻质燃料油；化工产品：溶剂"},{"_id":"6a836fb9af14b9c0e7b1ecd1","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy","methodology":"Stabilność oksydacyjna","parameters":[{"name":"Zakres","range":"(5,0 – 50,0) h"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Stabilność oksydacyjna\nZakres (5,0 – 50,0) h\nMetoda konduktometryczna","reference":"PN-EN 15751:2014-05","norm_bases":["PN-EN 15751:2014-05"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy Stabilność oksydacyjna\nZakres (5,0 – 50,0) h\nMetoda konduktometryczna PN-EN 15751:2014-05 Paliwa ciekle: olej napedowy Stabilnosc oksydacyjna\nZakres (5,0 – 50,0) h\nMetoda konduktometryczna PN-EN 15751:2014-05","categories":["petro"],"row_index":442,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Oxidation stability","parameters_en":[{"name":"Range","range":"(5,0 – 50,0) h"}],"search_en":"Liquid fuels: diesel fuel Oxidation stability Conductometric method Range PN-EN 15751:2014-05","technique_en":"Conductometric method","test_object_en":"Liquid fuels: diesel fuel","parameters_zh":[{"name":"范围","range":"(5,0 – 50,0) h"}],"search_zh":"液体燃料：柴油 氧化安定性 电导法 范围 PN-EN 15751:2014-05","technique_zh":"电导法","test_object_zh":"液体燃料：柴油","methodology_zh":"氧化安定性"},{"_id":"6a836fb9af14b9c0e7b1ecd2","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Stabilność oksydacyjna","parameters":[{"name":"Zakres","range":"(1,0 – 16,0) h"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Stabilność oksydacyjna\nZakres (1,0 – 16,0) h\nMetoda konduktometryczna","reference":"PN-EN 15751:2014-05","norm_bases":["PN-EN 15751:2014-05"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Stabilność oksydacyjna\nZakres (1,0 – 16,0) h\nMetoda konduktometryczna PN-EN 15751:2014-05 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Stabilnosc oksydacyjna\nZakres (1,0 – 16,0) h\nMetoda konduktometryczna PN-EN 15751:2014-05","categories":["petro"],"row_index":443,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Oxidation stability","parameters_en":[{"name":"Range","range":"(1,0 – 16,0) h"}],"search_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME) Oxidation stability Conductometric method Range PN-EN 15751:2014-05","technique_en":"Conductometric method","test_object_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME)","parameters_zh":[{"name":"范围","range":"(1,0 – 16,0) h"}],"search_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME） 氧化安定性 电导法 范围 PN-EN 15751:2014-05","technique_zh":"电导法","methodology_zh":"氧化安定性","test_object_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME）"},{"_id":"6a836fb9af14b9c0e7b1ecd3","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej opałowy lekki","methodology":"Zawartość siarki","parameters":[{"name":"Zakres","range":"(0,03 – 1,2) %(m/m)"}],"technique":"Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii","techniques":["Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii"],"computed":[],"activity":"Zawartość siarki\nZakres (0,03 – 1,2) %(m/m)\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii","reference":"PN-EN ISO 8754:2007+Ap1:2014-02","norm_bases":["PN-EN ISO 8754:2007+Ap1:2014-02"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej opałowy lekki Zawartość siarki\nZakres (0,03 – 1,2) %(m/m)\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii PN-EN ISO 8754:2007+Ap1:2014-02 Paliwa ciekle: olej opalowy lekki Zawartosc siarki\nZakres (0,03 – 1,2) %(m/m)\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersja energii PN-EN ISO 8754:2007+Ap1:2014-02","categories":["petro"],"row_index":444,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfur content","parameters_en":[{"name":"Range","range":"(0,03 – 1,2) %(m/m)"}],"search_en":"Liquid fuels: light fuel oil Sulfur content Energy-dispersive X-ray fluorescence spectrometry Range PN-EN ISO 8754:2007+Ap1:2014-02","technique_en":"Energy-dispersive X-ray fluorescence spectrometry","test_object_en":"Liquid fuels: light fuel oil","parameters_zh":[{"name":"范围","range":"(0,03 – 1,2) %(m/m)"}],"search_zh":"液体燃料：轻质燃料油 硫含量 能量色散X射线荧光光谱法 范围 PN-EN ISO 8754:2007+Ap1:2014-02","methodology_zh":"硫含量","technique_zh":"能量色散X射线荧光光谱法","test_object_zh":"液体燃料：轻质燃料油"},{"_id":"6a836fb9af14b9c0e7b1ecd4","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki","methodology":"Lepkość kinematyczna w temperaturze 40 °C","parameters":[{"name":"Zakres","range":"(2,000 – 10,00) mm2/s"}],"technique":"Metoda kapilarna","techniques":["Metoda kapilarna"],"computed":[],"activity":"Lepkość kinematyczna w temperaturze 40 °C\nZakres (2,000 – 10,00) mm2/s\nMetoda kapilarna","reference":"PN-EN ISO 3104:2024-01 Procedura A","norm_bases":["PN-EN ISO 3104:2024-01 Procedura A"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki Lepkość kinematyczna w temperaturze 40 °C\nZakres (2,000 – 10,00) mm2/s\nMetoda kapilarna PN-EN ISO 3104:2024-01 Procedura A Paliwa ciekle: olej napedowy, olej opalowy lekki Lepkosc kinematyczna w temperaturze 40 °C\nZakres (2,000 – 10,00) mm2/s\nMetoda kapilarna PN-EN ISO 3104:2024-01 Procedura A","categories":["petro"],"row_index":445,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kinematic viscosity at 40 °C","parameters_en":[{"name":"Range","range":"(2,000 – 10,00) mm2/s"}],"search_en":"Liquid fuels: diesel fuel, light fuel oil Kinematic viscosity at 40 °C Capillary method Range PN-EN ISO 3104:2024-01 Procedura A","technique_en":"Capillary method","test_object_en":"Liquid fuels: diesel fuel, light fuel oil","parameters_zh":[{"name":"范围","range":"(2,000 – 10,00) mm2/s"}],"search_zh":"液体燃料：柴油、轻质燃料油 毛细管法 范围 PN-EN ISO 3104:2024-01 Procedura A","technique_zh":"毛细管法","test_object_zh":"液体燃料：柴油、轻质燃料油"},{"_id":"6a836fb9af14b9c0e7b1ecd5","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki","methodology":"Temperatura zapłonu","parameters":[{"name":"Zakres","range":"(40,0 – 100,0) °C"}],"technique":"Metoda zamkniętego tygla Pensky’ego-Martensa","techniques":["Metoda zamkniętego tygla Pensky’ego-Martensa"],"computed":[],"activity":"Temperatura zapłonu\nZakres (40,0 – 100,0) °C\nMetoda zamkniętego tygla Pensky’ego-Martensa","reference":"PN-EN ISO 2719:2016-08+A1:2021-06","norm_bases":["PN-EN ISO 2719:2016-08+A1:2021-06"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki Temperatura zapłonu\nZakres (40,0 – 100,0) °C\nMetoda zamkniętego tygla Pensky’ego-Martensa PN-EN ISO 2719:2016-08+A1:2021-06 Paliwa ciekle: olej napedowy, olej opalowy lekki Temperatura zaplonu\nZakres (40,0 – 100,0) °C\nMetoda zamknietego tygla Pensky’ego-Martensa PN-EN ISO 2719:2016-08+A1:2021-06","categories":["petro"],"row_index":446,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Flash point","parameters_en":[{"name":"Range","range":"(40,0 – 100,0) °C"}],"search_en":"Liquid fuels: diesel fuel, light fuel oil Flash point Pensky-Martens closed cup method Range PN-EN ISO 2719:2016-08+A1:2021-06","technique_en":"Pensky-Martens closed cup method","test_object_en":"Liquid fuels: diesel fuel, light fuel oil","parameters_zh":[{"name":"范围","range":"(40,0 – 100,0) °C"}],"search_zh":"液体燃料：柴油、轻质燃料油 闪点 宾斯基-马丁闭口杯法 范围 PN-EN ISO 2719:2016-08+A1:2021-06","methodology_zh":"闪点","test_object_zh":"液体燃料：柴油、轻质燃料油","technique_zh":"宾斯基-马丁闭口杯法"},{"_id":"6a836fb9af14b9c0e7b1ecd6","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki","methodology":"Zawartość zanieczyszczeń","parameters":[{"name":"Zakres","range":"(12,0 – 26,0) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość zanieczyszczeń\nZakres (12,0 – 26,0) mg/kg\nMetoda wagowa","reference":"PN-EN 12662-1:2024-11","norm_bases":["PN-EN 12662-1:2024-11"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki Zawartość zanieczyszczeń\nZakres (12,0 – 26,0) mg/kg\nMetoda wagowa PN-EN 12662-1:2024-11 Paliwa ciekle: olej napedowy, olej opalowy lekki Zawartosc zanieczyszczen\nZakres (12,0 – 26,0) mg/kg\nMetoda wagowa PN-EN 12662-1:2024-11","categories":["petro"],"row_index":447,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Impurity content","parameters_en":[{"name":"Range","range":"(12,0 – 26,0) mg/kg"}],"search_en":"Liquid fuels: diesel fuel, light fuel oil Impurity content Gravimetric method Range PN-EN 12662-1:2024-11","technique_en":"Gravimetric method","test_object_en":"Liquid fuels: diesel fuel, light fuel oil","parameters_zh":[{"name":"范围","range":"(12,0 – 26,0) mg/kg"}],"search_zh":"液体燃料：柴油、轻质燃料油 杂质含量 重量法 范围 PN-EN 12662-1:2024-11","technique_zh":"重量法","methodology_zh":"杂质含量","test_object_zh":"液体燃料：柴油、轻质燃料油"},{"_id":"6a836fb9af14b9c0e7b1ecd7","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki","methodology":"Indeks cetanowy (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Indeks cetanowy (z obliczeń)","reference":"PN-EN ISO 4264:2018-08","norm_bases":["PN-EN ISO 4264:2018-08"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki Indeks cetanowy (z obliczeń) PN-EN ISO 4264:2018-08 Paliwa ciekle: olej napedowy, olej opalowy lekki Indeks cetanowy (z obliczen) PN-EN ISO 4264:2018-08","categories":["petro"],"row_index":448,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Cetane index (calculated)","search_en":"Liquid fuels: diesel fuel, light fuel oil Cetane index (calculated) PN-EN ISO 4264:2018-08","test_object_en":"Liquid fuels: diesel fuel, light fuel oil","search_zh":"液体燃料：柴油、轻质燃料油 十六烷指数（计算值） PN-EN ISO 4264:2018-08","test_object_zh":"液体燃料：柴油、轻质燃料油","methodology_zh":"十六烷指数（计算值）"},{"_id":"6a836fb9af14b9c0e7b1ecd8","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki","methodology":"Temperatura zablokowania zimnego filtru","parameters":[{"name":"[0","range":"(-30)] oC"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Temperatura zablokowania zimnego filtru\n[0 (-30)] oC\nMetoda optyczna","reference":"PN-EN 116:2015-09","norm_bases":["PN-EN 116:2015-09"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki Temperatura zablokowania zimnego filtru\n[0 (-30)] oC\nMetoda optyczna PN-EN 116:2015-09 Paliwa ciekle: olej napedowy, olej opalowy lekki Temperatura zablokowania zimnego filtru\n[0 (-30)] oC\nMetoda optyczna PN-EN 116:2015-09","categories":["petro"],"row_index":449,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Cold filter plugging point","parameters_en":[{"name":"[0","range":"(-30)] oC"}],"search_en":"Liquid fuels: diesel fuel, light fuel oil Cold filter plugging point Optical method [0 PN-EN 116:2015-09","technique_en":"Optical method","test_object_en":"Liquid fuels: diesel fuel, light fuel oil","search_zh":"液体燃料：柴油、轻质燃料油 冷滤点 光学法 PN-EN 116:2015-09","technique_zh":"光学法","test_object_zh":"液体燃料：柴油、轻质燃料油","methodology_zh":"冷滤点"},{"_id":"6a836fb9af14b9c0e7b1ecd9","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki","methodology":"Temperatura płynięcia","parameters":[{"name":"[10","range":"(-40,0)] oC"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Temperatura płynięcia\n[10 (-40,0)] oC\nMetoda optyczna","reference":"PN-EN ISO 3016:2019-06 | ASTM D 97-17b(2022)","norm_bases":["PN-EN ISO 3016:2019-06","ASTM D 97-17b(2022)"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki Temperatura płynięcia\n[10 (-40,0)] oC\nMetoda optyczna PN-EN ISO 3016:2019-06 | ASTM D 97-17b(2022) Paliwa ciekle: olej napedowy, olej opalowy lekki Temperatura plyniecia\n[10 (-40,0)] oC\nMetoda optyczna PN-EN ISO 3016:2019-06 | ASTM D 97-17b(2022)","categories":["petro"],"row_index":450,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Pour point","parameters_en":[{"name":"[10","range":"(-40,0)] oC"}],"search_en":"Liquid fuels: diesel fuel, light fuel oil Pour point Optical method [10 PN-EN ISO 3016:2019-06 | ASTM D 97-17b(2022)","technique_en":"Optical method","test_object_en":"Liquid fuels: diesel fuel, light fuel oil","search_zh":"液体燃料：柴油、轻质燃料油 倾点 光学法 PN-EN ISO 3016:2019-06 | ASTM D 97-17b(2022)","technique_zh":"光学法","test_object_zh":"液体燃料：柴油、轻质燃料油","methodology_zh":"倾点"},{"_id":"6a836fb9af14b9c0e7b1ecda","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki","methodology":"Zawartość wody","parameters":[{"name":"Zakres","range":"(30 – 1000) mg/kg"}],"technique":"Metoda miareczkowania kulometrycznego","techniques":["Metoda miareczkowania kulometrycznego"],"computed":[],"activity":"Zawartość wody\nZakres (30 – 1000) mg/kg\nMetoda miareczkowania kulometrycznego","reference":"PN-EN ISO 12937:2005+Ap1:2021-11","norm_bases":["PN-EN ISO 12937:2005+Ap1:2021-11"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki Zawartość wody\nZakres (30 – 1000) mg/kg\nMetoda miareczkowania kulometrycznego PN-EN ISO 12937:2005+Ap1:2021-11 Paliwa ciekle: olej napedowy, olej opalowy lekki Zawartosc wody\nZakres (30 – 1000) mg/kg\nMetoda miareczkowania kulometrycznego PN-EN ISO 12937:2005+Ap1:2021-11","categories":["petro","water"],"row_index":451,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water content","parameters_en":[{"name":"Range","range":"(30 – 1000) mg/kg"}],"search_en":"Liquid fuels: diesel fuel, light fuel oil Water content Coulometric titration method Range PN-EN ISO 12937:2005+Ap1:2021-11","technique_en":"Coulometric titration method","test_object_en":"Liquid fuels: diesel fuel, light fuel oil","methodology_zh":"水分含量","parameters_zh":[{"name":"范围","range":"(30 – 1000) mg/kg"}],"search_zh":"液体燃料：柴油、轻质燃料油 水分含量 库仑滴定法 范围 PN-EN ISO 12937:2005+Ap1:2021-11","technique_zh":"库仑滴定法","test_object_zh":"液体燃料：柴油、轻质燃料油"},{"_id":"6a836fb9af14b9c0e7b1ecdb","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki","methodology":"Temperatura mętnienia","parameters":[{"name":"[0","range":"(-45)] oC"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Temperatura mętnienia\n[0 (-45)] oC\nMetoda optyczna","reference":"PN-EN ISO 3015:2019-06","norm_bases":["PN-EN ISO 3015:2019-06"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki Temperatura mętnienia\n[0 (-45)] oC\nMetoda optyczna PN-EN ISO 3015:2019-06 Paliwa ciekle: olej napedowy, olej opalowy lekki Temperatura metnienia\n[0 (-45)] oC\nMetoda optyczna PN-EN ISO 3015:2019-06","categories":["petro"],"row_index":452,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Cloud point","parameters_en":[{"name":"[0","range":"(-45)] oC"}],"search_en":"Liquid fuels: diesel fuel, light fuel oil Cloud point Optical method [0 PN-EN ISO 3015:2019-06","technique_en":"Optical method","test_object_en":"Liquid fuels: diesel fuel, light fuel oil","search_zh":"液体燃料：柴油、轻质燃料油 浊点 光学法 PN-EN ISO 3015:2019-06","technique_zh":"光学法","test_object_zh":"液体燃料：柴油、轻质燃料油","methodology_zh":"浊点"},{"_id":"6a836fb9af14b9c0e7b1ecdc","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki","methodology":"Zawartość barwnika Solvent Red 19","parameters":[{"name":"Zakres","range":"(1,0 – 10,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość barwnika Solvent Red 19\nZakres (1,0 – 10,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-C-04426:2013-07 Metoda A","norm_bases":["PN-C-04426:2013-07 Metoda A"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki Zawartość barwnika Solvent Red 19\nZakres (1,0 – 10,0) mg/l\nMetoda spektrofotometryczna PN-C-04426:2013-07 Metoda A Paliwa ciekle: olej napedowy, olej opalowy lekki Zawartosc barwnika Solvent Red 19\nZakres (1,0 – 10,0) mg/l\nMetoda spektrofotometryczna PN-C-04426:2013-07 Metoda A","categories":["petro"],"row_index":453,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Solvent Red 19 dye content","parameters_en":[{"name":"Range","range":"(1,0 – 10,0) mg/l"}],"search_en":"Liquid fuels: diesel fuel, light fuel oil Solvent Red 19 dye content Spectrophotometric method Range PN-C-04426:2013-07 Metoda A","technique_en":"Spectrophotometric method","test_object_en":"Liquid fuels: diesel fuel, light fuel oil","parameters_zh":[{"name":"范围","range":"(1,0 – 10,0) mg/l"}],"search_zh":"液体燃料：柴油、轻质燃料油 溶剂红 19 着色剂含量 分光光度法 范围 PN-C-04426:2013-07 Metoda A","technique_zh":"分光光度法","test_object_zh":"液体燃料：柴油、轻质燃料油","methodology_zh":"溶剂红 19 着色剂含量"},{"_id":"6a836fb9af14b9c0e7b1ecdd","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki","methodology":"Zawartość estrów metylowych kwasów tłuszczowych (FAME)","parameters":[{"name":"Zakres","range":"(0,05 –10,0) %(v/v)"}],"technique":"Metoda spektrometrii w zakresie podczerwieni IR","techniques":["Metoda spektrometrii w zakresie podczerwieni IR"],"computed":[],"activity":"Zawartość estrów metylowych kwasów tłuszczowych (FAME)\nZakres (0,05 –10,0) %(v/v)\nMetoda spektrometrii w zakresie podczerwieni IR","reference":"PN-EN 14078:2014-06","norm_bases":["PN-EN 14078:2014-06"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki Zawartość estrów metylowych kwasów tłuszczowych (FAME)\nZakres (0,05 –10,0) %(v/v)\nMetoda spektrometrii w zakresie podczerwieni IR PN-EN 14078:2014-06 Paliwa ciekle: olej napedowy, olej opalowy lekki Zawartosc estrow metylowych kwasow tluszczowych (FAME)\nZakres (0,05 –10,0) %(v/v)\nMetoda spektrometrii w zakresie podczerwieni IR PN-EN 14078:2014-06","categories":["petro"],"row_index":454,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fatty acid methyl esters (FAME) content","parameters_en":[{"name":"Range","range":"(0,05 –10,0) %(v/v)"}],"search_en":"Liquid fuels: diesel fuel, light fuel oil Fatty acid methyl esters (FAME) content Spectrometry method in the infrared range IR Range PN-EN 14078:2014-06","technique_en":"Spectrometry method in the infrared range IR","test_object_en":"Liquid fuels: diesel fuel, light fuel oil","parameters_zh":[{"name":"范围","range":"(0,05 –10,0) %(v/v)"}],"search_zh":"液体燃料：柴油、轻质燃料油 脂肪酸甲酯（FAME）含量 红外光谱法 IR 范围 PN-EN 14078:2014-06","technique_zh":"红外光谱法 IR","test_object_zh":"液体燃料：柴油、轻质燃料油","methodology_zh":"脂肪酸甲酯（FAME）含量"},{"_id":"6a836fb9af14b9c0e7b1ecde","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość zanieczyszczeń","parameters":[{"name":"Zakres","range":"(5,0 – 27,0) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość zanieczyszczeń\nZakres (5,0 – 27,0) mg/kg\nMetoda wagowa","reference":"PN-EN 12662-2:2024-11","norm_bases":["PN-EN 12662-2:2024-11"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Zawartość zanieczyszczeń\nZakres (5,0 – 27,0) mg/kg\nMetoda wagowa PN-EN 12662-2:2024-11 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Zawartosc zanieczyszczen\nZakres (5,0 – 27,0) mg/kg\nMetoda wagowa PN-EN 12662-2:2024-11","categories":["petro"],"row_index":455,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Impurity content","parameters_en":[{"name":"Range","range":"(5,0 – 27,0) mg/kg"}],"search_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME) Impurity content Gravimetric method Range PN-EN 12662-2:2024-11","technique_en":"Gravimetric method","test_object_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME)","parameters_zh":[{"name":"范围","range":"(5,0 – 27,0) mg/kg"}],"search_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME） 杂质含量 重量法 范围 PN-EN 12662-2:2024-11","technique_zh":"重量法","methodology_zh":"杂质含量","test_object_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME）"},{"_id":"6a836fb9af14b9c0e7b1ecdf","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ropa naftowa","methodology":"Gęstość w temperaturze 15°C","parameters":[{"name":"Zakres","range":"(700,0 – 900,0) kg/m3"}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"computed":[],"activity":"Gęstość w temperaturze 15°C\nZakres (700,0 – 900,0) kg/m3\nMetoda oscylacyjna","reference":"PN-EN ISO 12185:2024-08","norm_bases":["PN-EN ISO 12185:2024-08"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ropa naftowa Gęstość w temperaturze 15°C\nZakres (700,0 – 900,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08 Ropa naftowa Gestosc w temperaturze 15°C\nZakres (700,0 – 900,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08","categories":["petro"],"row_index":456,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Density at 15°C","parameters_en":[{"name":"Range","range":"(700,0 – 900,0) kg/m3"}],"search_en":"Crude oil Density at 15°C Oscillation method Range PN-EN ISO 12185:2024-08","technique_en":"Oscillation method","test_object_en":"Crude oil","parameters_zh":[{"name":"范围","range":"(700,0 – 900,0) kg/m3"}],"search_zh":"原油 15°C 时的密度 振荡法 范围 PN-EN ISO 12185:2024-08","technique_zh":"振荡法","test_object_zh":"原油","methodology_zh":"15°C 时的密度"},{"_id":"6a836fb9af14b9c0e7b1ece0","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ropa naftowa, Paliwa ciekłe: olej opałowy ciężki","methodology":"Zawartość zanieczyszczeń","parameters":[{"name":"Zakres","range":"(0,01 – 0,40) %(m/m)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość zanieczyszczeń\nZakres (0,01 – 0,40) %(m/m)\nMetoda wagowa","reference":"PN-EN ISO 3735:2001","norm_bases":["PN-EN ISO 3735:2001"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ropa naftowa, Paliwa ciekłe: olej opałowy ciężki Zawartość zanieczyszczeń\nZakres (0,01 – 0,40) %(m/m)\nMetoda wagowa PN-EN ISO 3735:2001 Ropa naftowa, Paliwa ciekle: olej opalowy ciezki Zawartosc zanieczyszczen\nZakres (0,01 – 0,40) %(m/m)\nMetoda wagowa PN-EN ISO 3735:2001","categories":["petro"],"row_index":457,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Impurity content","parameters_en":[{"name":"Range","range":"(0,01 – 0,40) %(m/m)"}],"search_en":"Crude oil, Liquid fuels: heavy fuel oil Impurity content Gravimetric method Range PN-EN ISO 3735:2001","technique_en":"Gravimetric method","test_object_en":"Crude oil, Liquid fuels: heavy fuel oil","parameters_zh":[{"name":"范围","range":"(0,01 – 0,40) %(m/m)"}],"search_zh":"杂质含量 重量法 范围 PN-EN ISO 3735:2001","technique_zh":"重量法","methodology_zh":"杂质含量"},{"_id":"6a836fb9af14b9c0e7b1ece1","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Wyroby chemiczne: płyny niskokrzepnące","methodology":"Temperatura krystalizacji","parameters":[{"name":"[(-18)","range":"(-50)] oC"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Temperatura krystalizacji\n[(-18) (-50)] oC\nMetoda wizualna","reference":"PN-93/C-40008/10","norm_bases":["PN-93/C-40008/10"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby chemiczne: płyny niskokrzepnące Temperatura krystalizacji\n[(-18) (-50)] oC\nMetoda wizualna PN-93/C-40008/10 Wyroby chemiczne: plyny niskokrzepnace Temperatura krystalizacji\n[(-18) (-50)] oC\nMetoda wizualna PN-93/C-40008/10","categories":["other"],"row_index":458,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Crystallisation temperature","parameters_en":[{"name":"[(-18)","range":"(-50)] oC"}],"search_en":"Chemical products: low-freezing fluids Crystallisation temperature Visual method [(-18) PN-93/C-40008/10","technique_en":"Visual method","test_object_en":"Chemical products: low-freezing fluids","search_zh":"结晶温度 目视法 PN-93/C-40008/10","technique_zh":"目视法","methodology_zh":"结晶温度"},{"_id":"6a836fb9af14b9c0e7b1ece2","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiały smarne: oleje bazowe, oleje silnikowe, przemysłowe oleje smarowe","methodology":"Właściwości przeciwkorozyjne olejów mineralnych (korozja na trzpieniu stalowym)","parameters":[],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Właściwości przeciwkorozyjne olejów mineralnych (korozja na trzpieniu stalowym)\nMetoda wizualna","reference":"PN-ISO 7120:2011 Procedura A i B","norm_bases":["PN-ISO 7120:2011 Procedura A i B"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały smarne: oleje bazowe, oleje silnikowe, przemysłowe oleje smarowe Właściwości przeciwkorozyjne olejów mineralnych (korozja na trzpieniu stalowym)\nMetoda wizualna PN-ISO 7120:2011 Procedura A i B Materialy smarne: oleje bazowe, oleje silnikowe, przemyslowe oleje smarowe Wlasciwosci przeciwkorozyjne olejow mineralnych (korozja na trzpieniu stalowym)\nMetoda wizualna PN-ISO 7120:2011 Procedura A i B","categories":["materials","petro"],"row_index":459,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Anti-corrosion properties of mineral oils (rusting on a steel rod)","search_en":"Lubricants: base oils, engine oils, industrial lubricating oils Anti-corrosion properties of mineral oils (rusting on a steel rod) Visual method PN-ISO 7120:2011 Procedura A i B","technique_en":"Visual method","test_object_en":"Lubricants: base oils, engine oils, industrial lubricating oils","search_zh":"润滑材料：基础油、发动机油、工业润滑油 目视法 PN-ISO 7120:2011 Procedura A i B","technique_zh":"目视法","test_object_zh":"润滑材料：基础油、发动机油、工业润滑油"},{"_id":"6a836fb9af14b9c0e7b1ece3","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiały smarne: oleje bazowe, oleje silnikowe, przemysłowe oleje smarowe","methodology":"Lepkość kinematyczna w temperaturze 40 °C i 100 °C","parameters":[{"name":"Zakres","range":"(2,000 – 1200) mm2/s"}],"technique":"Metoda kapilarna","techniques":["Metoda kapilarna"],"computed":[],"activity":"Lepkość kinematyczna w temperaturze 40 °C i 100 °C\nZakres (2,000 – 1200) mm2/s\nMetoda kapilarna","reference":"PN-EN ISO 3104:2024-01 Procedura A","norm_bases":["PN-EN ISO 3104:2024-01 Procedura A"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały smarne: oleje bazowe, oleje silnikowe, przemysłowe oleje smarowe Lepkość kinematyczna w temperaturze 40 °C i 100 °C\nZakres (2,000 – 1200) mm2/s\nMetoda kapilarna PN-EN ISO 3104:2024-01 Procedura A Materialy smarne: oleje bazowe, oleje silnikowe, przemyslowe oleje smarowe Lepkosc kinematyczna w temperaturze 40 °C i 100 °C\nZakres (2,000 – 1200) mm2/s\nMetoda kapilarna PN-EN ISO 3104:2024-01 Procedura A","categories":["materials","petro"],"row_index":460,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kinematic viscosity at 40 °C and 100 °C","parameters_en":[{"name":"Range","range":"(2,000 – 1200) mm2/s"}],"search_en":"Lubricants: base oils, engine oils, industrial lubricating oils Kinematic viscosity at 40 °C and 100 °C Capillary method Range PN-EN ISO 3104:2024-01 Procedura A","technique_en":"Capillary method","test_object_en":"Lubricants: base oils, engine oils, industrial lubricating oils","parameters_zh":[{"name":"范围","range":"(2,000 – 1200) mm2/s"}],"search_zh":"润滑材料：基础油、发动机油、工业润滑油 毛细管法 范围 PN-EN ISO 3104:2024-01 Procedura A","technique_zh":"毛细管法","test_object_zh":"润滑材料：基础油、发动机油、工业润滑油"},{"_id":"6a836fb9af14b9c0e7b1ece4","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiały smarne: oleje bazowe, oleje silnikowe, przemysłowe oleje smarowe","methodology":"Temperatura płynięcia","parameters":[{"name":"[10","range":"(-45)] oC"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Temperatura płynięcia\n[10 (-45)] oC\nMetoda optyczna","reference":"PN-EN ISO 3016:2019-06","norm_bases":["PN-EN ISO 3016:2019-06"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały smarne: oleje bazowe, oleje silnikowe, przemysłowe oleje smarowe Temperatura płynięcia\n[10 (-45)] oC\nMetoda optyczna PN-EN ISO 3016:2019-06 Materialy smarne: oleje bazowe, oleje silnikowe, przemyslowe oleje smarowe Temperatura plyniecia\n[10 (-45)] oC\nMetoda optyczna PN-EN ISO 3016:2019-06","categories":["materials","petro"],"row_index":461,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Pour point","parameters_en":[{"name":"[10","range":"(-45)] oC"}],"search_en":"Lubricants: base oils, engine oils, industrial lubricating oils Pour point Optical method [10 PN-EN ISO 3016:2019-06","technique_en":"Optical method","test_object_en":"Lubricants: base oils, engine oils, industrial lubricating oils","search_zh":"润滑材料：基础油、发动机油、工业润滑油 倾点 光学法 PN-EN ISO 3016:2019-06","technique_zh":"光学法","methodology_zh":"倾点","test_object_zh":"润滑材料：基础油、发动机油、工业润滑油"},{"_id":"6a836fb9af14b9c0e7b1ece5","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiały smarne: oleje bazowe, oleje silnikowe, przemysłowe oleje smarowe","methodology":"Gęstość","parameters":[{"name":"Zakres","range":"(800,0 – 900,0) kg/m3"}],"technique":"Metoda areometryczna","techniques":["Metoda areometryczna"],"computed":[],"activity":"Gęstość\nZakres (800,0 – 900,0) kg/m3\nMetoda areometryczna","reference":"PN-EN ISO 3675:2004","norm_bases":["PN-EN ISO 3675:2004"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały smarne: oleje bazowe, oleje silnikowe, przemysłowe oleje smarowe Gęstość\nZakres (800,0 – 900,0) kg/m3\nMetoda areometryczna PN-EN ISO 3675:2004 Materialy smarne: oleje bazowe, oleje silnikowe, przemyslowe oleje smarowe Gestosc\nZakres (800,0 – 900,0) kg/m3\nMetoda areometryczna PN-EN ISO 3675:2004","categories":["materials","petro"],"row_index":462,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Density","parameters_en":[{"name":"Range","range":"(800,0 – 900,0) kg/m3"}],"search_en":"Lubricants: base oils, engine oils, industrial lubricating oils Density Hydrometer method Range PN-EN ISO 3675:2004","technique_en":"Hydrometer method","test_object_en":"Lubricants: base oils, engine oils, industrial lubricating oils","methodology_zh":"密度","parameters_zh":[{"name":"范围","range":"(800,0 – 900,0) kg/m3"}],"search_zh":"润滑材料：基础油、发动机油、工业润滑油 密度 比重计法 范围 PN-EN ISO 3675:2004","test_object_zh":"润滑材料：基础油、发动机油、工业润滑油","technique_zh":"比重计法"},{"_id":"6a836fb9af14b9c0e7b1ece6","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiały smarne: oleje bazowe, oleje silnikowe, przemysłowe oleje smarowe","methodology":"Temperatura zapłonu","parameters":[{"name":"Zakres","range":"(80,0 – 280,0) °C"}],"technique":"Metoda otwartego tygla Cleveland’a","techniques":["Metoda otwartego tygla Cleveland’a"],"computed":[],"activity":"Temperatura zapłonu\nZakres (80,0 – 280,0) °C\nMetoda otwartego tygla Cleveland’a","reference":"PN-EN ISO 2592:2017-10","norm_bases":["PN-EN ISO 2592:2017-10"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały smarne: oleje bazowe, oleje silnikowe, przemysłowe oleje smarowe Temperatura zapłonu\nZakres (80,0 – 280,0) °C\nMetoda otwartego tygla Cleveland’a PN-EN ISO 2592:2017-10 Materialy smarne: oleje bazowe, oleje silnikowe, przemyslowe oleje smarowe Temperatura zaplonu\nZakres (80,0 – 280,0) °C\nMetoda otwartego tygla Cleveland’a PN-EN ISO 2592:2017-10","categories":["materials","petro"],"row_index":463,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Flash point","parameters_en":[{"name":"Range","range":"(80,0 – 280,0) °C"}],"search_en":"Lubricants: base oils, engine oils, industrial lubricating oils Flash point Cleveland open cup method Range PN-EN ISO 2592:2017-10","technique_en":"Cleveland open cup method","test_object_en":"Lubricants: base oils, engine oils, industrial lubricating oils","parameters_zh":[{"name":"范围","range":"(80,0 – 280,0) °C"}],"search_zh":"润滑材料：基础油、发动机油、工业润滑油 闪点 范围 PN-EN ISO 2592:2017-10","methodology_zh":"闪点","test_object_zh":"润滑材料：基础油、发动机油、工业润滑油"},{"_id":"6a836fb9af14b9c0e7b1ece7","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiały smarne: oleje bazowe, oleje silnikowe, przemysłowe oleje smarowe","methodology":"Gęstość w temperaturze 15°C","parameters":[{"name":"Zakres","range":"(800,0 – 900,0) kg/m3"}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"computed":[],"activity":"Gęstość w temperaturze 15°C\nZakres (800,0 – 900,0) kg/m3\nMetoda oscylacyjna","reference":"PN-EN ISO 12185:2024-08","norm_bases":["PN-EN ISO 12185:2024-08"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały smarne: oleje bazowe, oleje silnikowe, przemysłowe oleje smarowe Gęstość w temperaturze 15°C\nZakres (800,0 – 900,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08 Materialy smarne: oleje bazowe, oleje silnikowe, przemyslowe oleje smarowe Gestosc w temperaturze 15°C\nZakres (800,0 – 900,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08","categories":["materials","petro"],"row_index":464,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Density at 15°C","parameters_en":[{"name":"Range","range":"(800,0 – 900,0) kg/m3"}],"search_en":"Lubricants: base oils, engine oils, industrial lubricating oils Density at 15°C Oscillation method Range PN-EN ISO 12185:2024-08","technique_en":"Oscillation method","test_object_en":"Lubricants: base oils, engine oils, industrial lubricating oils","parameters_zh":[{"name":"范围","range":"(800,0 – 900,0) kg/m3"}],"search_zh":"润滑材料：基础油、发动机油、工业润滑油 15°C 时的密度 振荡法 范围 PN-EN ISO 12185:2024-08","technique_zh":"振荡法","test_object_zh":"润滑材料：基础油、发动机油、工业润滑油","methodology_zh":"15°C 时的密度"},{"_id":"6a836fb9af14b9c0e7b1ece8","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiały smarne: oleje bazowe, oleje silnikowe, przemysłowe oleje smarowe","methodology":"Pozostałość po spopieleniu","parameters":[{"name":"Zakres","range":"(0,001 – 0,18) %(m/m)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Pozostałość po spopieleniu\nZakres (0,001 – 0,18) %(m/m)\nMetoda wagowa","reference":"PN-EN ISO 6245:2008","norm_bases":["PN-EN ISO 6245:2008"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały smarne: oleje bazowe, oleje silnikowe, przemysłowe oleje smarowe Pozostałość po spopieleniu\nZakres (0,001 – 0,18) %(m/m)\nMetoda wagowa PN-EN ISO 6245:2008 Materialy smarne: oleje bazowe, oleje silnikowe, przemyslowe oleje smarowe Pozostalosc po spopieleniu\nZakres (0,001 – 0,18) %(m/m)\nMetoda wagowa PN-EN ISO 6245:2008","categories":["materials","petro"],"row_index":465,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Residue after incineration","parameters_en":[{"name":"Range","range":"(0,001 – 0,18) %(m/m)"}],"search_en":"Lubricants: base oils, engine oils, industrial lubricating oils Residue after incineration Gravimetric method Range PN-EN ISO 6245:2008","technique_en":"Gravimetric method","test_object_en":"Lubricants: base oils, engine oils, industrial lubricating oils","parameters_zh":[{"name":"范围","range":"(0,001 – 0,18) %(m/m)"}],"search_zh":"润滑材料：基础油、发动机油、工业润滑油 灰化残渣 重量法 范围 PN-EN ISO 6245:2008","technique_zh":"重量法","test_object_zh":"润滑材料：基础油、发动机油、工业润滑油","methodology_zh":"灰化残渣"},{"_id":"6a836fb9af14b9c0e7b1ece9","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiały smarne: oleje bazowe, oleje silnikowe, przemysłowe oleje smarowe","methodology":"Działanie korodujące na miedź","parameters":[{"name":"Zakres","range":"1a – 4c (skala)"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Działanie korodujące na miedź\nZakres 1a – 4c (skala)\nMetoda wizualna","reference":"PN-EN ISO 2160:2004","norm_bases":["PN-EN ISO 2160:2004"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały smarne: oleje bazowe, oleje silnikowe, przemysłowe oleje smarowe Działanie korodujące na miedź\nZakres 1a – 4c (skala)\nMetoda wizualna PN-EN ISO 2160:2004 Materialy smarne: oleje bazowe, oleje silnikowe, przemyslowe oleje smarowe Dzialanie korodujace na miedz\nZakres 1a – 4c (skala)\nMetoda wizualna PN-EN ISO 2160:2004","categories":["materials","petro"],"row_index":466,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Copper strip corrosion","parameters_en":[{"name":"Range","range":"1a – 4c (skala)"}],"search_en":"Lubricants: base oils, engine oils, industrial lubricating oils Copper strip corrosion Visual method Range PN-EN ISO 2160:2004","technique_en":"Visual method","test_object_en":"Lubricants: base oils, engine oils, industrial lubricating oils","parameters_zh":[{"name":"范围","range":"1a – 4c (skala)"}],"search_zh":"润滑材料：基础油、发动机油、工业润滑油 铜片腐蚀 目视法 范围 PN-EN ISO 2160:2004","technique_zh":"目视法","test_object_zh":"润滑材料：基础油、发动机油、工业润滑油","methodology_zh":"铜片腐蚀"},{"_id":"6a836fb9af14b9c0e7b1ecea","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiały smarne: oleje bazowe, oleje silnikowe, przemysłowe oleje smarowe","methodology":"Działanie korodujące na metale","parameters":[],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Działanie korodujące na metale\nMetoda wizualna","reference":"PN-85/C-04093 metoda B","norm_bases":["PN-85/C-04093 metoda B"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały smarne: oleje bazowe, oleje silnikowe, przemysłowe oleje smarowe Działanie korodujące na metale\nMetoda wizualna PN-85/C-04093 metoda B Materialy smarne: oleje bazowe, oleje silnikowe, przemyslowe oleje smarowe Dzialanie korodujace na metale\nMetoda wizualna PN-85/C-04093 metoda B","categories":["materials","petro"],"row_index":467,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Corrosive action on metals","search_en":"Lubricants: base oils, engine oils, industrial lubricating oils Corrosive action on metals Visual method PN-85/C-04093 metoda B","technique_en":"Visual method","test_object_en":"Lubricants: base oils, engine oils, industrial lubricating oils","search_zh":"润滑材料：基础油、发动机油、工业润滑油 目视法 PN-85/C-04093 metoda B","technique_zh":"目视法","test_object_zh":"润滑材料：基础油、发动机油、工业润滑油"},{"_id":"6a836fb9af14b9c0e7b1eceb","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiały smarne: oleje bazowe, przemysłowe oleje smarowe","methodology":"Zdolność wydzielania powietrza","parameters":[{"name":"Zakres","range":"(1 – 15) minut"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zdolność wydzielania powietrza\nZakres (1 – 15) minut\nMetoda wagowa","reference":"PN-ISO 9120:2009+Ap1:2022-04","norm_bases":["PN-ISO 9120:2009+Ap1:2022-04"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały smarne: oleje bazowe, przemysłowe oleje smarowe Zdolność wydzielania powietrza\nZakres (1 – 15) minut\nMetoda wagowa PN-ISO 9120:2009+Ap1:2022-04 Materialy smarne: oleje bazowe, przemyslowe oleje smarowe Zdolnosc wydzielania powietrza\nZakres (1 – 15) minut\nMetoda wagowa PN-ISO 9120:2009+Ap1:2022-04","categories":["materials","petro"],"row_index":468,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air release properties","parameters_en":[{"name":"Range","range":"(1 – 15) minut"}],"search_en":"Lubricating materials: base oils, industrial lubricating oils Air release properties Gravimetric method Range PN-ISO 9120:2009+Ap1:2022-04","technique_en":"Gravimetric method","test_object_en":"Lubricating materials: base oils, industrial lubricating oils","parameters_zh":[{"name":"范围","range":"(1 – 15) minut"}],"search_zh":"重量法 范围 PN-ISO 9120:2009+Ap1:2022-04","technique_zh":"重量法"},{"_id":"6a836fb9af14b9c0e7b1ecec","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiały smarne: smary","methodology":"Temperatura kroplenia","parameters":[{"name":"Zakres","range":"(70 − 230) °C"}],"technique":"Metoda Ubbelohde`a","techniques":["Metoda Ubbelohde`a"],"computed":[],"activity":"Temperatura kroplenia\nZakres (70 − 230) °C\nMetoda Ubbelohde`a","reference":"PN-55/C-04020","norm_bases":["PN-55/C-04020"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały smarne: smary Temperatura kroplenia\nZakres (70 − 230) °C\nMetoda Ubbelohde`a PN-55/C-04020 Materialy smarne: smary Temperatura kroplenia\nZakres (70 − 230) °C\nMetoda Ubbelohde`a PN-55/C-04020","categories":["materials","petro"],"row_index":469,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dropping point","parameters_en":[{"name":"Range","range":"(70 − 230) °C"}],"search_en":"Lubricants: greases Dropping point Ubbelohde method Range PN-55/C-04020","technique_en":"Ubbelohde method","test_object_en":"Lubricants: greases","parameters_zh":[{"name":"范围","range":"(70 − 230) °C"}],"search_zh":"润滑材料：润滑脂 滴点 范围 PN-55/C-04020","test_object_zh":"润滑材料：润滑脂","methodology_zh":"滴点"},{"_id":"6a836fb9af14b9c0e7b1eced","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiały smarne: smary","methodology":"Temperatura kroplenia","parameters":[{"name":"Zakres","range":"(130 – 300) °C"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Temperatura kroplenia\nZakres (130 – 300) °C\nMetoda wizualna","reference":"PN-ISO 2176:2011+A1:2021-07","norm_bases":["PN-ISO 2176:2011+A1:2021-07"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały smarne: smary Temperatura kroplenia\nZakres (130 – 300) °C\nMetoda wizualna PN-ISO 2176:2011+A1:2021-07 Materialy smarne: smary Temperatura kroplenia\nZakres (130 – 300) °C\nMetoda wizualna PN-ISO 2176:2011+A1:2021-07","categories":["materials","petro"],"row_index":470,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dropping point","parameters_en":[{"name":"Range","range":"(130 – 300) °C"}],"search_en":"Lubricants: greases Dropping point Visual method Range PN-ISO 2176:2011+A1:2021-07","technique_en":"Visual method","test_object_en":"Lubricants: greases","parameters_zh":[{"name":"范围","range":"(130 – 300) °C"}],"search_zh":"润滑材料：润滑脂 滴点 目视法 范围 PN-ISO 2176:2011+A1:2021-07","technique_zh":"目视法","test_object_zh":"润滑材料：润滑脂","methodology_zh":"滴点"},{"_id":"6a836fb9af14b9c0e7b1ecee","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Materiały smarne: smary","methodology":"Penetracja","parameters":[{"name":"Zakres","range":"200 – 420"}],"technique":"Metoda penetracji stożkiem","techniques":["Metoda penetracji stożkiem"],"computed":[],"activity":"Penetracja\nZakres 200 – 420\nMetoda penetracji stożkiem","reference":"PN-ISO 2137:2021-07","norm_bases":["PN-ISO 2137:2021-07"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały smarne: smary Penetracja\nZakres 200 – 420\nMetoda penetracji stożkiem PN-ISO 2137:2021-07 Materialy smarne: smary Penetracja\nZakres 200 – 420\nMetoda penetracji stozkiem PN-ISO 2137:2021-07","categories":["materials","petro"],"row_index":471,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Penetration","parameters_en":[{"name":"Range","range":"200 – 420"}],"search_en":"Lubricants: greases Penetration Cone penetration method Range PN-ISO 2137:2021-07","technique_en":"Cone penetration method","test_object_en":"Lubricants: greases","parameters_zh":[{"name":"范围","range":"200 – 420"}],"search_zh":"润滑材料：润滑脂 针入度 锥入度法 范围 PN-ISO 2137:2021-07","methodology_zh":"针入度","technique_zh":"锥入度法","test_object_zh":"润滑材料：润滑脂"},{"_id":"6a836fb9af14b9c0e7b1ecef","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki, wody opadowe","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[{"name":"Temperatura pobranej próbki wody opadowej, ścieków"},{"name":"Zakres","range":"(2,0 – 30,0) °C"}],"technique":"Metoda manualna","techniques":["Metoda manualna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura pobranej próbki wody opadowej, ścieków\nZakres (2,0 – 30,0) °C\nMetoda manualna","reference":"PN-ISO 5667-10:2021-11 Metoda nr 111 Wydanie 5 z dnia 01.07.2020","norm_bases":["PN-ISO 5667-10:2021-11 Metoda nr 111 Wydanie 5 z dnia 01.07.2020"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, wody opadowe Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura pobranej próbki wody opadowej, ścieków\nZakres (2,0 – 30,0) °C\nMetoda manualna PN-ISO 5667-10:2021-11 Metoda nr 111 Wydanie 5 z dnia 01.07.2020 Scieki, wody opadowe Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nTemperatura pobranej probki wody opadowej, sciekow\nZakres (2,0 – 30,0) °C\nMetoda manualna PN-ISO 5667-10:2021-11 Metoda nr 111 Wydanie 5 z dnia 01.07.2020","categories":["water"],"row_index":472,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","parameters_en":[{"name":"Temperature of the collected sample of rainwater, wastewater"},{"name":"Range","range":"(2,0 – 30,0) °C"}],"search_en":"Wastewater, rainwater Sampling for chemical and physical testing Manual method Temperature of the collected sample of rainwater, wastewater Range PN-ISO 5667-10:2021-11 Metoda nr 111 Wydanie 5 z dnia 01.07.2020","technique_en":"Manual method","test_object_en":"Wastewater, rainwater","methodology_zh":"化学与物理检测用样品采集","parameters_zh":[{"name":"Temperatura pobranej próbki wody opadowej, ścieków"},{"name":"范围","range":"(2,0 – 30,0) °C"}],"search_zh":"化学与物理检测用样品采集 手工法 范围 PN-ISO 5667-10:2021-11 Metoda nr 111 Wydanie 5 z dnia 01.07.2020","technique_zh":"手工法"},{"_id":"6a836fb9af14b9c0e7b1ecf0","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Scieki pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":473,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"search_en":"Wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Wastewater","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"污水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"污水"},{"_id":"6a836fb9af14b9c0e7b1ecf1","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(5 – 200) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (5 – 200) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Zawiesiny ogólne\nZakres (5 – 200) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Scieki Zawiesiny ogolne\nZakres (5 – 200) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":474,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(5 – 200) mg/l"}],"search_en":"Wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Wastewater","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(5 – 200) mg/l"}],"search_zh":"污水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"污水"},{"_id":"6a836fb9af14b9c0e7b1ecf2","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie fenolu (indeks fenolowy)","parameters":[{"name":"Zakres","range":"(0,002 – 0,100) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fenolu (indeks fenolowy)\nZakres (0,002 – 0,100) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6439:1994 metoda B","norm_bases":["PN-ISO 6439:1994 metoda B"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie fenolu (indeks fenolowy)\nZakres (0,002 – 0,100) mg/l\nMetoda spektrofotometryczna PN-ISO 6439:1994 metoda B Scieki Stezenie fenolu (indeks fenolowy)\nZakres (0,002 – 0,100) mg/l\nMetoda spektrofotometryczna PN-ISO 6439:1994 metoda B","categories":["water"],"row_index":475,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phenol concentration (phenol index)","parameters_en":[{"name":"Range","range":"(0,002 – 0,100) mg/l"}],"search_en":"Wastewater Phenol concentration (phenol index) Spectrophotometric method Range PN-ISO 6439:1994 metoda B","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(0,002 – 0,100) mg/l"}],"search_zh":"污水 分光光度法 范围 PN-ISO 6439:1994 metoda B","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a836fb9af14b9c0e7b1ecf3","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"Indeks oleju mineralnego","parameters":[{"name":"Zakres","range":"(2,0 – 1000,0) mg/l"}],"technique":"Metoda spektroskopii laserowej","techniques":["Metoda spektroskopii laserowej"],"computed":[],"activity":"Indeks oleju mineralnego\nZakres (2,0 – 1000,0) mg/l\nMetoda spektroskopii laserowej","reference":"ASTM D 7678-17(2022)","norm_bases":["ASTM D 7678-17(2022)"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Indeks oleju mineralnego\nZakres (2,0 – 1000,0) mg/l\nMetoda spektroskopii laserowej ASTM D 7678-17(2022) Scieki Indeks oleju mineralnego\nZakres (2,0 – 1000,0) mg/l\nMetoda spektroskopii laserowej ASTM D 7678-17(2022)","categories":["water","petro"],"row_index":476,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mineral oil index","parameters_en":[{"name":"Range","range":"(2,0 – 1000,0) mg/l"}],"search_en":"Wastewater Mineral oil index Laser spectroscopy method Range ASTM D 7678-17(2022)","technique_en":"Laser spectroscopy method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(2,0 – 1000,0) mg/l"}],"search_zh":"污水 矿物油指数 范围 ASTM D 7678-17(2022)","test_object_zh":"污水","methodology_zh":"矿物油指数"},{"_id":"6a836fb9af14b9c0e7b1ecf4","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5 – 150) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5 – 150) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie chlorków\nZakres (5 – 150) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Scieki Stezenie chlorkow\nZakres (5 – 150) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":477,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5 – 150) mg/l"}],"search_en":"Wastewater Chloride concentration Titrimetric method Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Wastewater","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5 – 150) mg/l"}],"search_zh":"污水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"污水"},{"_id":"6a836fb9af14b9c0e7b1ecf5","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu BZT5","parameters":[{"name":"Zakres","range":"(3 – 600) mg O2/l"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu BZT5\nZakres (3 – 600) mg O2/l\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu BZT5\nZakres (3 – 600) mg O2/l\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Scieki Biochemiczne zapotrzebowanie tlenu BZT5\nZakres (3 – 600) mg O2/l\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":478,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand BOD5","parameters_en":[{"name":"Range","range":"(3 – 600) mg O2/l"}],"search_en":"Wastewater Biochemical oxygen demand BOD5 Electrochemical method Range PN-EN ISO 5815-1:2019-12","technique_en":"Electrochemical method","test_object_en":"Wastewater","methodology_zh":"生化需氧量 BZT5（BOD5）","parameters_zh":[{"name":"范围","range":"(3 – 600) mg O2/l"}],"search_zh":"污水 生化需氧量 BZT5（BOD5） 电化学法 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"污水"},{"_id":"6a836fb9af14b9c0e7b1ecf6","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"Chemiczne zapotrzebowanie tlenu","parameters":[{"name":"Zakres","range":"(30,0 – 1000) mg O2/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu\nZakres (30,0 – 1000) mg O2/l\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Chemiczne zapotrzebowanie tlenu\nZakres (30,0 – 1000) mg O2/l\nMetoda spektrofotometryczna PN-ISO 15705:2005 Scieki Chemiczne zapotrzebowanie tlenu\nZakres (30,0 – 1000) mg O2/l\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":479,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand","parameters_en":[{"name":"Range","range":"(30,0 – 1000) mg O2/l"}],"search_en":"Wastewater Chemical oxygen demand Spectrophotometric method Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(30,0 – 1000) mg O2/l"}],"search_zh":"污水 化学需氧量（COD） 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"污水","methodology_zh":"化学需氧量（COD）"},{"_id":"6a836fb9af14b9c0e7b1ecf7","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie fosforu","parameters":[{"name":"Zakres","range":"(0,10 – 25,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu\nZakres (0,10 – 25,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 pkt 8","norm_bases":["PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 pkt 8"],"lab_section":"Pracownia Produktów Naftowych w Jedliczu PP5","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie fosforu\nZakres (0,10 – 25,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 pkt 8 Scieki Stezenie fosforu\nZakres (0,10 – 25,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 pkt 8","categories":["water"],"row_index":480,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,10 – 25,0) mg/l"}],"search_en":"Wastewater Phosphorus concentration Spectrophotometric method Range PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 pkt 8","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(0,10 – 25,0) mg/l"}],"search_zh":"污水 磷浓度 分光光度法 范围 PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 pkt 8","technique_zh":"分光光度法","test_object_zh":"污水","methodology_zh":"磷浓度"},{"_id":"6a836fb9af14b9c0e7b1ecf8","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki, biopaliwa ciekłe: bioetanol, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Pobieranie próbek ze zbiorników do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek ze zbiorników do badań chemicznych i fizycznych","reference":"PN-EN ISO 3170:2025-12 z wyłączeniem 8.3.1.3- 8.3.1.6, 8.3.1.8, 8.3.2, 8.7- 8.9, 9.8, 10.6, 10.7","norm_bases":["PN-EN ISO 3170:2025-12 z wyłączeniem 8.3.1.3- 8.3.1.6, 8.3.1.8, 8.3.2, 8.7- 8.9, 9.8, 10.6, 10.7"],"lab_section":"Punkt Obsługi Laboratoryjnej w Ostrowie Wielkopolskim PP7/3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki, biopaliwa ciekłe: bioetanol, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Pobieranie próbek ze zbiorników do badań chemicznych i fizycznych PN-EN ISO 3170:2025-12 z wyłączeniem 8.3.1.3- 8.3.1.6, 8.3.1.8, 8.3.2, 8.7- 8.9, 9.8, 10.6, 10.7 Paliwa ciekle: benzyna bezolowiowa, olej napedowy, olej opalowy lekki, biopaliwa ciekle: bioetanol, biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Pobieranie probek ze zbiornikow do badan chemicznych i fizycznych PN-EN ISO 3170:2025-12 z wylaczeniem 8.3.1.3- 8.3.1.6, 8.3.1.8, 8.3.2, 8.7- 8.9, 9.8, 10.6, 10.7","categories":["petro"],"row_index":481,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling from tanks for chemical and physical testing","search_en":"Liquid fuels: unleaded petrol, diesel fuel, light heating oil, liquid biofuels: bioethanol, liquid biofuels: fatty acid methyl esters (FAME) Sampling from tanks for chemical and physical testing PN-EN ISO 3170:2025-12 z wyłączeniem 8.3.1.3- 8.3.1.6, 8.3.1.8, 8.3.2, 8.7- 8.9, 9.8, 10.6, 10.7","test_object_en":"Liquid fuels: unleaded petrol, diesel fuel, light heating oil, liquid biofuels: bioethanol, liquid biofuels: fatty acid methyl esters (FAME)","methodology_zh":"自储罐采集化学和物理检测样品","search_zh":"自储罐采集化学和物理检测样品 PN-EN ISO 3170:2025-12 z wyłączeniem 8.3.1.3- 8.3.1.6, 8.3.1.8, 8.3.2, 8.7- 8.9, 9.8, 10.6, 10.7"},{"_id":"6a836fb9af14b9c0e7b1ecf9","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki, biopaliwa ciekłe: bioetanol, estry metylowe kwasów tłuszczowych (FAME)","methodology":"Gęstość w temperaturze 15°C","parameters":[{"name":"Zakres","range":"(700,0 – 900,0) kg/m3"}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"computed":[],"activity":"Gęstość w temperaturze 15°C\nZakres (700,0 – 900,0) kg/m3\nMetoda oscylacyjna","reference":"PN-EN ISO 12185:2024-08","norm_bases":["PN-EN ISO 12185:2024-08"],"lab_section":"Punkt Obsługi Laboratoryjnej w Ostrowie Wielkopolskim PP7/3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki, biopaliwa ciekłe: bioetanol, estry metylowe kwasów tłuszczowych (FAME) Gęstość w temperaturze 15°C\nZakres (700,0 – 900,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08 Paliwa ciekle: benzyna bezolowiowa, olej napedowy, olej opalowy lekki, biopaliwa ciekle: bioetanol, estry metylowe kwasow tluszczowych (FAME) Gestosc w temperaturze 15°C\nZakres (700,0 – 900,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08","categories":["petro"],"row_index":482,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Density at 15°C","parameters_en":[{"name":"Range","range":"(700,0 – 900,0) kg/m3"}],"search_en":"Liquid fuels: unleaded petrol, diesel fuel, light heating oil, liquid biofuels: bioethanol, fatty acid methyl esters (FAME) Density at 15°C Oscillation method Range PN-EN ISO 12185:2024-08","technique_en":"Oscillation method","test_object_en":"Liquid fuels: unleaded petrol, diesel fuel, light heating oil, liquid biofuels: bioethanol, fatty acid methyl esters (FAME)","parameters_zh":[{"name":"范围","range":"(700,0 – 900,0) kg/m3"}],"search_zh":"15°C 时的密度 振荡法 范围 PN-EN ISO 12185:2024-08","technique_zh":"振荡法","methodology_zh":"15°C 时的密度"},{"_id":"6a836fb9af14b9c0e7b1ecfa","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki","methodology":"Skład frakcyjny","parameters":[{"name":"Zakres","range":"(30,0 – 370,0) °C"}],"technique":"Metoda destylacyjna","techniques":["Metoda destylacyjna"],"computed":[],"activity":"Skład frakcyjny\nZakres (30,0 – 370,0) °C\nMetoda destylacyjna","reference":"PN-EN ISO 3405:2019-05","norm_bases":["PN-EN ISO 3405:2019-05"],"lab_section":"Punkt Obsługi Laboratoryjnej w Ostrowie Wielkopolskim PP7/3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki Skład frakcyjny\nZakres (30,0 – 370,0) °C\nMetoda destylacyjna PN-EN ISO 3405:2019-05 Paliwa ciekle: benzyna bezolowiowa, olej napedowy, olej opalowy lekki Sklad frakcyjny\nZakres (30,0 – 370,0) °C\nMetoda destylacyjna PN-EN ISO 3405:2019-05","categories":["petro"],"row_index":483,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fractional composition","parameters_en":[{"name":"Range","range":"(30,0 – 370,0) °C"}],"search_en":"Liquid fuels: unleaded petrol, diesel fuel, light fuel oil Fractional composition Distillation method Range PN-EN ISO 3405:2019-05","technique_en":"Distillation method","test_object_en":"Liquid fuels: unleaded petrol, diesel fuel, light fuel oil","parameters_zh":[{"name":"范围","range":"(30,0 – 370,0) °C"}],"search_zh":"液体燃料：无铅汽油、柴油、轻质燃料油 馏程组成 蒸馏法 范围 PN-EN ISO 3405:2019-05","technique_zh":"蒸馏法","methodology_zh":"馏程组成","test_object_zh":"液体燃料：无铅汽油、柴油、轻质燃料油"},{"_id":"6a836fb9af14b9c0e7b1ecfb","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki","methodology":"Zawartość siarki","parameters":[{"name":"Zakres","range":"(3,0 – 100) mg/kg"}],"technique":"Metoda fluorescencji w nadfiolecie","techniques":["Metoda fluorescencji w nadfiolecie"],"computed":[],"activity":"Zawartość siarki\nZakres (3,0 – 100) mg/kg\nMetoda fluorescencji w nadfiolecie","reference":"PN-EN ISO 20846:2020-03","norm_bases":["PN-EN ISO 20846:2020-03"],"lab_section":"Punkt Obsługi Laboratoryjnej w Ostrowie Wielkopolskim PP7/3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki Zawartość siarki\nZakres (3,0 – 100) mg/kg\nMetoda fluorescencji w nadfiolecie PN-EN ISO 20846:2020-03 Paliwa ciekle: benzyna bezolowiowa, olej napedowy, olej opalowy lekki Zawartosc siarki\nZakres (3,0 – 100) mg/kg\nMetoda fluorescencji w nadfiolecie PN-EN ISO 20846:2020-03","categories":["petro"],"row_index":484,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfur content","parameters_en":[{"name":"Range","range":"(3,0 – 100) mg/kg"}],"search_en":"Liquid fuels: unleaded petrol, diesel fuel, light fuel oil Sulfur content Ultraviolet fluorescence method Range PN-EN ISO 20846:2020-03","technique_en":"Ultraviolet fluorescence method","test_object_en":"Liquid fuels: unleaded petrol, diesel fuel, light fuel oil","parameters_zh":[{"name":"范围","range":"(3,0 – 100) mg/kg"}],"search_zh":"液体燃料：无铅汽油、柴油、轻质燃料油 硫含量 紫外荧光法 范围 PN-EN ISO 20846:2020-03","methodology_zh":"硫含量","technique_zh":"紫外荧光法","test_object_zh":"液体燃料：无铅汽油、柴油、轻质燃料油"},{"_id":"6a836fb9af14b9c0e7b1ecfc","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Prężność par nasyconych powietrzem","parameters":[{"name":"Zakres","range":"(40,0 – 106,0) kPa"}],"technique":"Metoda mini Reid","techniques":["Metoda mini Reid"],"computed":[],"activity":"Prężność par nasyconych powietrzem\nZakres (40,0 – 106,0) kPa\nMetoda mini Reid","reference":"PN-EN 13016-1:2024-11","norm_bases":["PN-EN 13016-1:2024-11"],"lab_section":"Punkt Obsługi Laboratoryjnej w Ostrowie Wielkopolskim PP7/3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Prężność par nasyconych powietrzem\nZakres (40,0 – 106,0) kPa\nMetoda mini Reid PN-EN 13016-1:2024-11 Paliwa ciekle: benzyna bezolowiowa Preznosc par nasyconych powietrzem\nZakres (40,0 – 106,0) kPa\nMetoda mini Reid PN-EN 13016-1:2024-11","categories":["petro","environment"],"row_index":485,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air saturated vapour pressure","parameters_en":[{"name":"Range","range":"(40,0 – 106,0) kPa"}],"search_en":"Liquid fuels: unleaded petrol Air saturated vapour pressure Mini Reid method Range PN-EN 13016-1:2024-11","technique_en":"Mini Reid method","test_object_en":"Liquid fuels: unleaded petrol","parameters_zh":[{"name":"范围","range":"(40,0 – 106,0) kPa"}],"search_zh":"液体燃料：无铅汽油 空气饱和蒸气压 迷你雷德法 范围 PN-EN 13016-1:2024-11","test_object_zh":"液体燃料：无铅汽油","technique_zh":"迷你雷德法","methodology_zh":"空气饱和蒸气压"},{"_id":"6a836fb9af14b9c0e7b1ecfd","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Zawartość tlenowych związków organicznych","parameters":[{"name":"Zakres","range":"(0,17 – 15,0) %(v/v)"},{"name":"Całkowita zawartość organicznie związanego tlenu (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość tlenowych związków organicznych\nZakres:\nZakres (0,17 – 15,0) %(v/v)\nCałkowita zawartość organicznie związanego tlenu (z obliczeń)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13132:2005","norm_bases":["PN-EN 13132:2005"],"lab_section":"Punkt Obsługi Laboratoryjnej w Ostrowie Wielkopolskim PP7/3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Zawartość tlenowych związków organicznych\nZakres:\nZakres (0,17 – 15,0) %(v/v)\nCałkowita zawartość organicznie związanego tlenu (z obliczeń)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13132:2005 Paliwa ciekle: benzyna bezolowiowa Zawartosc tlenowych zwiazkow organicznych\nZakres:\nZakres (0,17 – 15,0) %(v/v)\nCalkowita zawartosc organicznie zwiazanego tlenu (z obliczen)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13132:2005","categories":["petro"],"row_index":486,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of oxygenated organic compounds","parameters_en":[{"name":"Range","range":"(0,17 – 15,0) %(v/v)"},{"name":"Total organically bound oxygen content (calculated)"}],"search_en":"Liquid fuels: unleaded petrol Content of oxygenated organic compounds Gas chromatography with flame ionization detection (GC-FID) Range Total organically bound oxygen content (calculated) PN-EN 13132:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Liquid fuels: unleaded petrol","parameters_zh":[{"name":"范围","range":"(0,17 – 15,0) %(v/v)"},{"name":"有机结合氧总量（由计算得出）"}],"search_zh":"液体燃料：无铅汽油 含氧有机化合物含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 有机结合氧总量（由计算得出） PN-EN 13132:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"液体燃料：无铅汽油","methodology_zh":"含氧有机化合物含量"},{"_id":"6a836fb9af14b9c0e7b1ecfe","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Indeks lotności (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Indeks lotności (z obliczeń)","reference":"PN-EN 228+A1:2017-06 p. 5.5.2","norm_bases":["PN-EN 228+A1:2017-06 p. 5.5.2"],"lab_section":"Punkt Obsługi Laboratoryjnej w Ostrowie Wielkopolskim PP7/3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Indeks lotności (z obliczeń) PN-EN 228+A1:2017-06 p. 5.5.2 Paliwa ciekle: benzyna bezolowiowa Indeks lotnosci (z obliczen) PN-EN 228+A1:2017-06 p. 5.5.2","categories":["petro"],"row_index":487,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Volatility index (calculated)","search_en":"Liquid fuels: unleaded petrol Volatility index (calculated) PN-EN 228+A1:2017-06 p. 5.5.2","test_object_en":"Liquid fuels: unleaded petrol","search_zh":"液体燃料：无铅汽油 挥发性指数（计算值） PN-EN 228+A1:2017-06 p. 5.5.2","test_object_zh":"液体燃料：无铅汽油","methodology_zh":"挥发性指数（计算值）"},{"_id":"6a836fb9af14b9c0e7b1ecff","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Liczba oktanowa LOM","parameters":[{"name":"Zakres","range":"84,0 – 90,0"}],"technique":"Metoda silnikowa","techniques":["Metoda silnikowa"],"computed":[],"activity":"Liczba oktanowa LOM\nZakres 84,0 – 90,0\nMetoda silnikowa","reference":"PN-EN ISO 5163:2014-08","norm_bases":["PN-EN ISO 5163:2014-08"],"lab_section":"Punkt Obsługi Laboratoryjnej w Ostrowie Wielkopolskim PP7/3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Liczba oktanowa LOM\nZakres 84,0 – 90,0\nMetoda silnikowa PN-EN ISO 5163:2014-08 Paliwa ciekle: benzyna bezolowiowa Liczba oktanowa LOM\nZakres 84,0 – 90,0\nMetoda silnikowa PN-EN ISO 5163:2014-08","categories":["petro"],"row_index":488,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Motor octane number MON","parameters_en":[{"name":"Range","range":"84,0 – 90,0"}],"search_en":"Liquid fuels: unleaded petrol Motor octane number MON Motor method Range PN-EN ISO 5163:2014-08","technique_en":"Motor method","test_object_en":"Liquid fuels: unleaded petrol","parameters_zh":[{"name":"范围","range":"84,0 – 90,0"}],"search_zh":"液体燃料：无铅汽油 马达法辛烷值 MON 发动机法 范围 PN-EN ISO 5163:2014-08","technique_zh":"发动机法","test_object_zh":"液体燃料：无铅汽油","methodology_zh":"马达法辛烷值 MON"},{"_id":"6a836fb9af14b9c0e7b1ed00","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki","methodology":"Temperatura zapłonu","parameters":[{"name":"Zakres","range":"(45,0 – 75,0) °C"}],"technique":"Metoda zamkniętego tygla Pensky`ego-Martensa","techniques":["Metoda zamkniętego tygla Pensky`ego-Martensa"],"computed":[],"activity":"Temperatura zapłonu\nZakres (45,0 – 75,0) °C\nMetoda zamkniętego tygla Pensky`ego-Martensa","reference":"PN-EN ISO 2719:2016-08+A1:2021-06","norm_bases":["PN-EN ISO 2719:2016-08+A1:2021-06"],"lab_section":"Punkt Obsługi Laboratoryjnej w Ostrowie Wielkopolskim PP7/3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki Temperatura zapłonu\nZakres (45,0 – 75,0) °C\nMetoda zamkniętego tygla Pensky`ego-Martensa PN-EN ISO 2719:2016-08+A1:2021-06 Paliwa ciekle: olej napedowy, olej opalowy lekki Temperatura zaplonu\nZakres (45,0 – 75,0) °C\nMetoda zamknietego tygla Pensky`ego-Martensa PN-EN ISO 2719:2016-08+A1:2021-06","categories":["petro"],"row_index":489,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Flash point","parameters_en":[{"name":"Range","range":"(45,0 – 75,0) °C"}],"search_en":"Liquid fuels: diesel fuel, light fuel oil Flash point Pensky-Martens closed cup method Range PN-EN ISO 2719:2016-08+A1:2021-06","technique_en":"Pensky-Martens closed cup method","test_object_en":"Liquid fuels: diesel fuel, light fuel oil","parameters_zh":[{"name":"范围","range":"(45,0 – 75,0) °C"}],"search_zh":"液体燃料：柴油、轻质燃料油 闪点 范围 PN-EN ISO 2719:2016-08+A1:2021-06","methodology_zh":"闪点","test_object_zh":"液体燃料：柴油、轻质燃料油"},{"_id":"6a836fb9af14b9c0e7b1ed01","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki","methodology":"Zawartość zanieczyszczeń","parameters":[{"name":"Zakres","range":"(12,0 – 26,0) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość zanieczyszczeń\nZakres (12,0 – 26,0) mg/kg\nMetoda wagowa","reference":"PN-EN 12662-1:2024-11","norm_bases":["PN-EN 12662-1:2024-11"],"lab_section":"Punkt Obsługi Laboratoryjnej w Ostrowie Wielkopolskim PP7/3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki Zawartość zanieczyszczeń\nZakres (12,0 – 26,0) mg/kg\nMetoda wagowa PN-EN 12662-1:2024-11 Paliwa ciekle: olej napedowy, olej opalowy lekki Zawartosc zanieczyszczen\nZakres (12,0 – 26,0) mg/kg\nMetoda wagowa PN-EN 12662-1:2024-11","categories":["petro"],"row_index":490,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Impurity content","parameters_en":[{"name":"Range","range":"(12,0 – 26,0) mg/kg"}],"search_en":"Liquid fuels: diesel fuel, light fuel oil Impurity content Gravimetric method Range PN-EN 12662-1:2024-11","technique_en":"Gravimetric method","test_object_en":"Liquid fuels: diesel fuel, light fuel oil","parameters_zh":[{"name":"范围","range":"(12,0 – 26,0) mg/kg"}],"search_zh":"液体燃料：柴油、轻质燃料油 杂质含量 重量法 范围 PN-EN 12662-1:2024-11","technique_zh":"重量法","methodology_zh":"杂质含量","test_object_zh":"液体燃料：柴油、轻质燃料油"},{"_id":"6a836fb9af14b9c0e7b1ed02","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość wody","parameters":[{"name":"Zakres","range":"(30 – 1000) mg/kg"}],"technique":"Metoda miareczkowania kulometrycznego","techniques":["Metoda miareczkowania kulometrycznego"],"computed":[],"activity":"Zawartość wody\nZakres (30 – 1000) mg/kg\nMetoda miareczkowania kulometrycznego","reference":"PN-EN ISO 12937:2005+Ap1:2021-11","norm_bases":["PN-EN ISO 12937:2005+Ap1:2021-11"],"lab_section":"Punkt Obsługi Laboratoryjnej w Ostrowie Wielkopolskim PP7/3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Zawartość wody\nZakres (30 – 1000) mg/kg\nMetoda miareczkowania kulometrycznego PN-EN ISO 12937:2005+Ap1:2021-11 Paliwa ciekle: olej napedowy, olej opalowy lekki, biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Zawartosc wody\nZakres (30 – 1000) mg/kg\nMetoda miareczkowania kulometrycznego PN-EN ISO 12937:2005+Ap1:2021-11","categories":["petro","water"],"row_index":491,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water content","parameters_en":[{"name":"Range","range":"(30 – 1000) mg/kg"}],"search_en":"Liquid fuels: diesel fuel, light fuel oil, liquid biofuels: fatty acid methyl esters (FAME) Water content Coulometric titration method Range PN-EN ISO 12937:2005+Ap1:2021-11","technique_en":"Coulometric titration method","test_object_en":"Liquid fuels: diesel fuel, light fuel oil, liquid biofuels: fatty acid methyl esters (FAME)","methodology_zh":"水分含量","parameters_zh":[{"name":"范围","range":"(30 – 1000) mg/kg"}],"search_zh":"液体燃料：柴油、轻质燃料油；液体生物燃料：脂肪酸甲酯（FAME） 水分含量 库仑滴定法 范围 PN-EN ISO 12937:2005+Ap1:2021-11","technique_zh":"库仑滴定法","test_object_zh":"液体燃料：柴油、轻质燃料油；液体生物燃料：脂肪酸甲酯（FAME）"},{"_id":"6a836fb9af14b9c0e7b1ed03","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość zanieczyszczeń","parameters":[{"name":"Zakres","range":"(5,0 – 27,0) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość zanieczyszczeń\nZakres (5,0 – 27,0) mg/kg\nMetoda wagowa","reference":"PN-EN 12662-2:2024-11","norm_bases":["PN-EN 12662-2:2024-11"],"lab_section":"Punkt Obsługi Laboratoryjnej w Ostrowie Wielkopolskim PP7/3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Zawartość zanieczyszczeń\nZakres (5,0 – 27,0) mg/kg\nMetoda wagowa PN-EN 12662-2:2024-11 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Zawartosc zanieczyszczen\nZakres (5,0 – 27,0) mg/kg\nMetoda wagowa PN-EN 12662-2:2024-11","categories":["petro"],"row_index":492,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Impurity content","parameters_en":[{"name":"Range","range":"(5,0 – 27,0) mg/kg"}],"search_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME) Impurity content Gravimetric method Range PN-EN 12662-2:2024-11","technique_en":"Gravimetric method","test_object_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME)","parameters_zh":[{"name":"范围","range":"(5,0 – 27,0) mg/kg"}],"search_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME） 杂质含量 重量法 范围 PN-EN 12662-2:2024-11","technique_zh":"重量法","methodology_zh":"杂质含量","test_object_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME）"},{"_id":"6a836fb9af14b9c0e7b1ed04","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Temperatura zablokowania zimnego filtra","parameters":[{"name":"[0 °C","range":"(-40)°C]"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Temperatura zablokowania zimnego filtra\n[0 °C (-40)°C]\nMetoda optyczna","reference":"PN-EN 116:2015-09","norm_bases":["PN-EN 116:2015-09"],"lab_section":"Punkt Obsługi Laboratoryjnej w Ostrowie Wielkopolskim PP7/3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Temperatura zablokowania zimnego filtra\n[0 °C (-40)°C]\nMetoda optyczna PN-EN 116:2015-09 Paliwa ciekle: olej napedowy, biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Temperatura zablokowania zimnego filtra\n[0 °C (-40)°C]\nMetoda optyczna PN-EN 116:2015-09","categories":["petro"],"row_index":493,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Cold filter plugging point","parameters_en":[{"name":"[0 °C","range":"(-40)°C]"}],"search_en":"Liquid fuels: diesel fuel, liquid biofuels: fatty acid methyl esters (FAME) Cold filter plugging point Optical method [0 °C PN-EN 116:2015-09","technique_en":"Optical method","test_object_en":"Liquid fuels: diesel fuel, liquid biofuels: fatty acid methyl esters (FAME)","search_zh":"冷滤点 光学法 PN-EN 116:2015-09","technique_zh":"光学法","methodology_zh":"冷滤点"},{"_id":"6a836fb9af14b9c0e7b1ed05","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy","methodology":"Zawartość estrów metylowych kwasów tłuszczowych (FAME)","parameters":[{"name":"Zakres","range":"(3,0 – 10,0) %(v/v)"}],"technique":"Metoda spektrometrii w zakresie podczerwieni IR","techniques":["Metoda spektrometrii w zakresie podczerwieni IR"],"computed":[],"activity":"Zawartość estrów metylowych kwasów tłuszczowych (FAME)\nZakres (3,0 – 10,0) %(v/v)\nMetoda spektrometrii w zakresie podczerwieni IR","reference":"PN-EN 14078:2014-06","norm_bases":["PN-EN 14078:2014-06"],"lab_section":"Punkt Obsługi Laboratoryjnej w Ostrowie Wielkopolskim PP7/3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy Zawartość estrów metylowych kwasów tłuszczowych (FAME)\nZakres (3,0 – 10,0) %(v/v)\nMetoda spektrometrii w zakresie podczerwieni IR PN-EN 14078:2014-06 Paliwa ciekle: olej napedowy Zawartosc estrow metylowych kwasow tluszczowych (FAME)\nZakres (3,0 – 10,0) %(v/v)\nMetoda spektrometrii w zakresie podczerwieni IR PN-EN 14078:2014-06","categories":["petro"],"row_index":494,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fatty acid methyl esters (FAME) content","parameters_en":[{"name":"Range","range":"(3,0 – 10,0) %(v/v)"}],"search_en":"Liquid fuels: diesel fuel Fatty acid methyl esters (FAME) content Spectrometry method in the infrared range IR Range PN-EN 14078:2014-06","technique_en":"Spectrometry method in the infrared range IR","test_object_en":"Liquid fuels: diesel fuel","parameters_zh":[{"name":"范围","range":"(3,0 – 10,0) %(v/v)"}],"search_zh":"液体燃料：柴油 脂肪酸甲酯（FAME）含量 红外光谱法 IR 范围 PN-EN 14078:2014-06","test_object_zh":"液体燃料：柴油","technique_zh":"红外光谱法 IR","methodology_zh":"脂肪酸甲酯（FAME）含量"},{"_id":"6a836fb9af14b9c0e7b1ed06","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy","methodology":"Indeks cetanowy (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Indeks cetanowy (z obliczeń)","reference":"PN-EN ISO 4264:2018-08","norm_bases":["PN-EN ISO 4264:2018-08"],"lab_section":"Punkt Obsługi Laboratoryjnej w Ostrowie Wielkopolskim PP7/3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy Indeks cetanowy (z obliczeń) PN-EN ISO 4264:2018-08 Paliwa ciekle: olej napedowy Indeks cetanowy (z obliczen) PN-EN ISO 4264:2018-08","categories":["petro"],"row_index":495,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Cetane index (calculated)","search_en":"Liquid fuels: diesel fuel Cetane index (calculated) PN-EN ISO 4264:2018-08","test_object_en":"Liquid fuels: diesel fuel","search_zh":"液体燃料：柴油 十六烷指数（计算值） PN-EN ISO 4264:2018-08","test_object_zh":"液体燃料：柴油","methodology_zh":"十六烷指数（计算值）"},{"_id":"6a836fb9af14b9c0e7b1ed07","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy","methodology":"Liczba cetanowa","parameters":[{"name":"Zakres","range":"50,0 – 60,0"}],"technique":"Metoda silnikowa","techniques":["Metoda silnikowa"],"computed":[],"activity":"Liczba cetanowa\nZakres 50,0 – 60,0\nMetoda silnikowa","reference":"PN-EN ISO 5165:2021-02","norm_bases":["PN-EN ISO 5165:2021-02"],"lab_section":"Punkt Obsługi Laboratoryjnej w Ostrowie Wielkopolskim PP7/3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy Liczba cetanowa\nZakres 50,0 – 60,0\nMetoda silnikowa PN-EN ISO 5165:2021-02 Paliwa ciekle: olej napedowy Liczba cetanowa\nZakres 50,0 – 60,0\nMetoda silnikowa PN-EN ISO 5165:2021-02","categories":["petro"],"row_index":496,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Cetane number","parameters_en":[{"name":"Range","range":"50,0 – 60,0"}],"search_en":"Liquid fuels: diesel fuel Cetane number Motor method Range PN-EN ISO 5165:2021-02","technique_en":"Motor method","test_object_en":"Liquid fuels: diesel fuel","parameters_zh":[{"name":"范围","range":"50,0 – 60,0"}],"search_zh":"液体燃料：柴油 十六烷值 发动机法 范围 PN-EN ISO 5165:2021-02","test_object_zh":"液体燃料：柴油","technique_zh":"发动机法","methodology_zh":"十六烷值"},{"_id":"6a836fb9af14b9c0e7b1ed08","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych ( FAME)","methodology":"Skłonność do blokowania filtra po wychładzaniu","parameters":[{"name":"Zakres","range":"(30 – 360) s"}],"technique":"Metoda CSFT","techniques":["Metoda CSFT"],"computed":[],"activity":"Skłonność do blokowania filtra po wychładzaniu\nZakres (30 – 360) s\nMetoda CSFT","reference":"ASTM D 7501-22","norm_bases":["ASTM D 7501-22"],"lab_section":"Punkt Obsługi Laboratoryjnej w Ostrowie Wielkopolskim PP7/3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych ( FAME) Skłonność do blokowania filtra po wychładzaniu\nZakres (30 – 360) s\nMetoda CSFT ASTM D 7501-22 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych ( FAME) Sklonnosc do blokowania filtra po wychladzaniu\nZakres (30 – 360) s\nMetoda CSFT ASTM D 7501-22","categories":["petro"],"row_index":497,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Tendency to plug the filter after cooling","parameters_en":[{"name":"Range","range":"(30 – 360) s"}],"search_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters ( FAME) Tendency to plug the filter after cooling CSFT method Range ASTM D 7501-22","technique_en":"CSFT method","test_object_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters ( FAME)","parameters_zh":[{"name":"范围","range":"(30 – 360) s"}],"search_zh":"冷却后堵塞滤器的倾向 范围 ASTM D 7501-22","methodology_zh":"冷却后堵塞滤器的倾向"},{"_id":"6a836fb9af14b9c0e7b1ed09","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych ( FAME)","methodology":"Stabilność oksydacyjna","parameters":[{"name":"Zakres","range":"(1,0 – 16,0) h"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Stabilność oksydacyjna\nZakres (1,0 – 16,0) h\nMetoda konduktometryczna","reference":"PN-EN 15751:2014-05","norm_bases":["PN-EN 15751:2014-05"],"lab_section":"Punkt Obsługi Laboratoryjnej w Ostrowie Wielkopolskim PP7/3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych ( FAME) Stabilność oksydacyjna\nZakres (1,0 – 16,0) h\nMetoda konduktometryczna PN-EN 15751:2014-05 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych ( FAME) Stabilnosc oksydacyjna\nZakres (1,0 – 16,0) h\nMetoda konduktometryczna PN-EN 15751:2014-05","categories":["petro"],"row_index":498,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Oxidation stability","parameters_en":[{"name":"Range","range":"(1,0 – 16,0) h"}],"search_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters ( FAME) Oxidation stability Conductometric method Range PN-EN 15751:2014-05","technique_en":"Conductometric method","test_object_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters ( FAME)","parameters_zh":[{"name":"范围","range":"(1,0 – 16,0) h"}],"search_zh":"氧化安定性 电导法 范围 PN-EN 15751:2014-05","technique_zh":"电导法","methodology_zh":"氧化安定性"},{"_id":"6a836fb9af14b9c0e7b1ed0a","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Temperatura mętnienia","parameters":[{"name":"[0oC","range":"(-25) oC]"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Temperatura mętnienia\n[0oC (-25) oC]\nMetoda optyczna","reference":"PN-EN ISO 3015:2019-06","norm_bases":["PN-EN ISO 3015:2019-06"],"lab_section":"Punkt Obsługi Laboratoryjnej w Ostrowie Wielkopolskim PP7/3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Temperatura mętnienia\n[0oC (-25) oC]\nMetoda optyczna PN-EN ISO 3015:2019-06 Paliwa ciekle: olej napedowy, biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Temperatura metnienia\n[0oC (-25) oC]\nMetoda optyczna PN-EN ISO 3015:2019-06","categories":["petro"],"row_index":499,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Cloud point","parameters_en":[{"name":"[0oC","range":"(-25) oC]"}],"search_en":"Liquid fuels: diesel fuel, liquid biofuels: fatty acid methyl esters (FAME) Cloud point Optical method [0oC PN-EN ISO 3015:2019-06","technique_en":"Optical method","test_object_en":"Liquid fuels: diesel fuel, liquid biofuels: fatty acid methyl esters (FAME)","search_zh":"浊点 光学法 PN-EN ISO 3015:2019-06","technique_zh":"光学法","methodology_zh":"浊点"},{"_id":"6a836fb9af14b9c0e7b1ed0b","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: bioetanol","methodology":"Moc","parameters":[{"name":"Zakres","range":"(95,0 – 100,0) %(v/v)"}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"computed":[],"activity":"Moc\nZakres (95,0 – 100,0) %(v/v)\nMetoda oscylacyjna","reference":"PN-A-79528-3:2007 p. 5.2","norm_bases":["PN-A-79528-3:2007 p. 5.2"],"lab_section":"Punkt Obsługi Laboratoryjnej w Ostrowie Wielkopolskim PP7/3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: bioetanol Moc\nZakres (95,0 – 100,0) %(v/v)\nMetoda oscylacyjna PN-A-79528-3:2007 p. 5.2 Paliwa ciekle: biopaliwa ciekle: bioetanol Moc\nZakres (95,0 – 100,0) %(v/v)\nMetoda oscylacyjna PN-A-79528-3:2007 p. 5.2","categories":["petro"],"row_index":500,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Power","parameters_en":[{"name":"Range","range":"(95,0 – 100,0) %(v/v)"}],"search_en":"Liquid fuels: liquid biofuels: bioethanol Power Oscillation method Range PN-A-79528-3:2007 p. 5.2","technique_en":"Oscillation method","test_object_en":"Liquid fuels: liquid biofuels: bioethanol","parameters_zh":[{"name":"范围","range":"(95,0 – 100,0) %(v/v)"}],"search_zh":"液体燃料：液体生物燃料：生物乙醇 功率 振荡法 范围 PN-A-79528-3:2007 p. 5.2","technique_zh":"振荡法","methodology_zh":"功率","test_object_zh":"液体燃料：液体生物燃料：生物乙醇"},{"_id":"6a836fb9af14b9c0e7b1ed0c","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, biopaliwa ciekłe: olej napędowy z FAME","methodology":"Stabilność oksydacyjna","parameters":[{"name":"Zakres","range":"(5,0 – 48,0) h"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Stabilność oksydacyjna\nZakres (5,0 – 48,0) h\nMetoda konduktometryczna","reference":"PN-EN 15751:2014-05","norm_bases":["PN-EN 15751:2014-05"],"lab_section":"Punkt Obsługi Laboratoryjnej w Ostrowie Wielkopolskim PP7/3","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, biopaliwa ciekłe: olej napędowy z FAME Stabilność oksydacyjna\nZakres (5,0 – 48,0) h\nMetoda konduktometryczna PN-EN 15751:2014-05 Paliwa ciekle: olej napedowy, biopaliwa ciekle: olej napedowy z FAME Stabilnosc oksydacyjna\nZakres (5,0 – 48,0) h\nMetoda konduktometryczna PN-EN 15751:2014-05","categories":["petro"],"row_index":501,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Oxidation stability","parameters_en":[{"name":"Range","range":"(5,0 – 48,0) h"}],"search_en":"Liquid fuels: diesel fuel, liquid biofuels: diesel fuel with FAME Oxidation stability Conductometric method Range PN-EN 15751:2014-05","technique_en":"Conductometric method","test_object_en":"Liquid fuels: diesel fuel, liquid biofuels: diesel fuel with FAME","parameters_zh":[{"name":"范围","range":"(5,0 – 48,0) h"}],"search_zh":"液体燃料：柴油；液体生物燃料：含 FAME 的柴油 氧化安定性 电导法 范围 PN-EN 15751:2014-05","technique_zh":"电导法","methodology_zh":"氧化安定性","test_object_zh":"液体燃料：柴油；液体生物燃料：含 FAME 的柴油"},{"_id":"6a836fb9af14b9c0e7b1ed0d","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Pobieranie próbek ze zbiorników do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek ze zbiorników do badań chemicznych i fizycznych","reference":"PN-EN ISO 3170:2025-12 Z wyłączeniem 8.3.1.3 - 8.3.1.6, 8.3.1.8, 8.3.2, 8.7- 8.9, 9.8, 10.6, 10.7","norm_bases":["PN-EN ISO 3170:2025-12 Z wyłączeniem 8.3.1.3 - 8.3.1.6, 8.3.1.8, 8.3.2, 8.7- 8.9, 9.8, 10.6, 10.7"],"lab_section":"Punkt Obsługi Laboratoryjnej w Lublinie PP7/1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Pobieranie próbek ze zbiorników do badań chemicznych i fizycznych PN-EN ISO 3170:2025-12 Z wyłączeniem 8.3.1.3 - 8.3.1.6, 8.3.1.8, 8.3.2, 8.7- 8.9, 9.8, 10.6, 10.7 Paliwa ciekle: benzyna bezolowiowa, olej napedowy, olej opalowy lekki, biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Pobieranie probek ze zbiornikow do badan chemicznych i fizycznych PN-EN ISO 3170:2025-12 Z wylaczeniem 8.3.1.3 - 8.3.1.6, 8.3.1.8, 8.3.2, 8.7- 8.9, 9.8, 10.6, 10.7","categories":["petro"],"row_index":502,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling from tanks for chemical and physical testing","search_en":"Liquid fuels: unleaded petrol, diesel fuel, light heating oil, liquid biofuels: fatty acid methyl esters (FAME) Sampling from tanks for chemical and physical testing PN-EN ISO 3170:2025-12 Z wyłączeniem 8.3.1.3 - 8.3.1.6, 8.3.1.8, 8.3.2, 8.7- 8.9, 9.8, 10.6, 10.7","test_object_en":"Liquid fuels: unleaded petrol, diesel fuel, light heating oil, liquid biofuels: fatty acid methyl esters (FAME)","methodology_zh":"自储罐采集化学和物理检测样品","search_zh":"自储罐采集化学和物理检测样品 PN-EN ISO 3170:2025-12 Z wyłączeniem 8.3.1.3 - 8.3.1.6, 8.3.1.8, 8.3.2, 8.7- 8.9, 9.8, 10.6, 10.7"},{"_id":"6a836fb9af14b9c0e7b1ed0e","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Liczba oktanowa LOM","parameters":[{"name":"Zakres","range":"80,0 – 90,0"}],"technique":"Metoda silnikowa","techniques":["Metoda silnikowa"],"computed":[],"activity":"Liczba oktanowa LOM\nZakres 80,0 – 90,0\nMetoda silnikowa","reference":"PN-EN ISO 5163:2014-08","norm_bases":["PN-EN ISO 5163:2014-08"],"lab_section":"Punkt Obsługi Laboratoryjnej w Lublinie PP7/1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Liczba oktanowa LOM\nZakres 80,0 – 90,0\nMetoda silnikowa PN-EN ISO 5163:2014-08 Paliwa ciekle: benzyna bezolowiowa Liczba oktanowa LOM\nZakres 80,0 – 90,0\nMetoda silnikowa PN-EN ISO 5163:2014-08","categories":["petro"],"row_index":503,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Motor octane number MON","parameters_en":[{"name":"Range","range":"80,0 – 90,0"}],"search_en":"Liquid fuels: unleaded petrol Motor octane number MON Motor method Range PN-EN ISO 5163:2014-08","technique_en":"Motor method","test_object_en":"Liquid fuels: unleaded petrol","parameters_zh":[{"name":"范围","range":"80,0 – 90,0"}],"search_zh":"液体燃料：无铅汽油 马达法辛烷值 MON 发动机法 范围 PN-EN ISO 5163:2014-08","technique_zh":"发动机法","test_object_zh":"液体燃料：无铅汽油","methodology_zh":"马达法辛烷值 MON"},{"_id":"6a836fb9af14b9c0e7b1ed0f","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Prężność par nasyconych powietrzem","parameters":[{"name":"Zakres","range":"(40,0 – 106,0) kPa"}],"technique":"Metoda mini Reid","techniques":["Metoda mini Reid"],"computed":[],"activity":"Prężność par nasyconych powietrzem\nZakres (40,0 – 106,0) kPa\nMetoda mini Reid","reference":"PN-EN 13016-1:2024-11","norm_bases":["PN-EN 13016-1:2024-11"],"lab_section":"Punkt Obsługi Laboratoryjnej w Lublinie PP7/1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Prężność par nasyconych powietrzem\nZakres (40,0 – 106,0) kPa\nMetoda mini Reid PN-EN 13016-1:2024-11 Paliwa ciekle: benzyna bezolowiowa Preznosc par nasyconych powietrzem\nZakres (40,0 – 106,0) kPa\nMetoda mini Reid PN-EN 13016-1:2024-11","categories":["petro","environment"],"row_index":504,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air saturated vapour pressure","parameters_en":[{"name":"Range","range":"(40,0 – 106,0) kPa"}],"search_en":"Liquid fuels: unleaded petrol Air saturated vapour pressure Mini Reid method Range PN-EN 13016-1:2024-11","technique_en":"Mini Reid method","test_object_en":"Liquid fuels: unleaded petrol","parameters_zh":[{"name":"范围","range":"(40,0 – 106,0) kPa"}],"search_zh":"液体燃料：无铅汽油 空气饱和蒸气压 迷你雷德法 范围 PN-EN 13016-1:2024-11","test_object_zh":"液体燃料：无铅汽油","technique_zh":"迷你雷德法","methodology_zh":"空气饱和蒸气压"},{"_id":"6a836fb9af14b9c0e7b1ed10","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Indeks lotności (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Indeks lotności (z obliczeń)","reference":"PN-EN 228+A1:2017-06 p. 5.5.2","norm_bases":["PN-EN 228+A1:2017-06 p. 5.5.2"],"lab_section":"Punkt Obsługi Laboratoryjnej w Lublinie PP7/1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Indeks lotności (z obliczeń) PN-EN 228+A1:2017-06 p. 5.5.2 Paliwa ciekle: benzyna bezolowiowa Indeks lotnosci (z obliczen) PN-EN 228+A1:2017-06 p. 5.5.2","categories":["petro"],"row_index":505,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Volatility index (calculated)","search_en":"Liquid fuels: unleaded petrol Volatility index (calculated) PN-EN 228+A1:2017-06 p. 5.5.2","test_object_en":"Liquid fuels: unleaded petrol","search_zh":"液体燃料：无铅汽油 挥发性指数（计算值） PN-EN 228+A1:2017-06 p. 5.5.2","test_object_zh":"液体燃料：无铅汽油","methodology_zh":"挥发性指数（计算值）"},{"_id":"6a836fb9af14b9c0e7b1ed11","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Zawartość siarki","parameters":[{"name":"Zakres","range":"(3,0 – 100) mg/kg"}],"technique":"Metoda fluorescencji w nadfiolecie","techniques":["Metoda fluorescencji w nadfiolecie"],"computed":[],"activity":"Zawartość siarki\nZakres (3,0 – 100) mg/kg\nMetoda fluorescencji w nadfiolecie","reference":"PN-EN ISO 20846:2020-03","norm_bases":["PN-EN ISO 20846:2020-03"],"lab_section":"Punkt Obsługi Laboratoryjnej w Lublinie PP7/1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Zawartość siarki\nZakres (3,0 – 100) mg/kg\nMetoda fluorescencji w nadfiolecie PN-EN ISO 20846:2020-03 Paliwa ciekle: benzyna bezolowiowa Zawartosc siarki\nZakres (3,0 – 100) mg/kg\nMetoda fluorescencji w nadfiolecie PN-EN ISO 20846:2020-03","categories":["petro"],"row_index":506,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfur content","parameters_en":[{"name":"Range","range":"(3,0 – 100) mg/kg"}],"search_en":"Liquid fuels: unleaded petrol Sulfur content Ultraviolet fluorescence method Range PN-EN ISO 20846:2020-03","technique_en":"Ultraviolet fluorescence method","test_object_en":"Liquid fuels: unleaded petrol","parameters_zh":[{"name":"范围","range":"(3,0 – 100) mg/kg"}],"search_zh":"液体燃料：无铅汽油 硫含量 紫外荧光法 范围 PN-EN ISO 20846:2020-03","methodology_zh":"硫含量","technique_zh":"紫外荧光法","test_object_zh":"液体燃料：无铅汽油"},{"_id":"6a836fb9af14b9c0e7b1ed12","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Gęstość w temperaturze 15°C","parameters":[{"name":"Zakres","range":"(700,0 – 800,0) kg/m3"}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"computed":[],"activity":"Gęstość w temperaturze 15°C\nZakres (700,0 – 800,0) kg/m3\nMetoda oscylacyjna","reference":"PN-EN ISO 12185:2024-08","norm_bases":["PN-EN ISO 12185:2024-08"],"lab_section":"Punkt Obsługi Laboratoryjnej w Lublinie PP7/1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Gęstość w temperaturze 15°C\nZakres (700,0 – 800,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08 Paliwa ciekle: benzyna bezolowiowa Gestosc w temperaturze 15°C\nZakres (700,0 – 800,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08","categories":["petro"],"row_index":507,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Density at 15°C","parameters_en":[{"name":"Range","range":"(700,0 – 800,0) kg/m3"}],"search_en":"Liquid fuels: unleaded petrol Density at 15°C Oscillation method Range PN-EN ISO 12185:2024-08","technique_en":"Oscillation method","test_object_en":"Liquid fuels: unleaded petrol","parameters_zh":[{"name":"范围","range":"(700,0 – 800,0) kg/m3"}],"search_zh":"液体燃料：无铅汽油 15°C 时的密度 振荡法 范围 PN-EN ISO 12185:2024-08","technique_zh":"振荡法","test_object_zh":"液体燃料：无铅汽油","methodology_zh":"15°C 时的密度"},{"_id":"6a836fb9af14b9c0e7b1ed13","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Skład frakcyjny","parameters":[{"name":"Zakres","range":"(30,0 – 220,0) oC"}],"technique":"Metoda destylacyjna","techniques":["Metoda destylacyjna"],"computed":[],"activity":"Skład frakcyjny\nZakres (30,0 – 220,0) oC\nMetoda destylacyjna","reference":"PN-EN ISO 3405:2019-05","norm_bases":["PN-EN ISO 3405:2019-05"],"lab_section":"Punkt Obsługi Laboratoryjnej w Lublinie PP7/1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Skład frakcyjny\nZakres (30,0 – 220,0) oC\nMetoda destylacyjna PN-EN ISO 3405:2019-05 Paliwa ciekle: benzyna bezolowiowa Sklad frakcyjny\nZakres (30,0 – 220,0) oC\nMetoda destylacyjna PN-EN ISO 3405:2019-05","categories":["petro"],"row_index":508,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fractional composition","parameters_en":[{"name":"Range","range":"(30,0 – 220,0) oC"}],"search_en":"Liquid fuels: unleaded petrol Fractional composition Distillation method Range PN-EN ISO 3405:2019-05","technique_en":"Distillation method","test_object_en":"Liquid fuels: unleaded petrol","parameters_zh":[{"name":"范围","range":"(30,0 – 220,0) oC"}],"search_zh":"液体燃料：无铅汽油 馏程组成 蒸馏法 范围 PN-EN ISO 3405:2019-05","technique_zh":"蒸馏法","methodology_zh":"馏程组成","test_object_zh":"液体燃料：无铅汽油"},{"_id":"6a836fb9af14b9c0e7b1ed14","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Zawartość tlenowych związków organicznych","parameters":[{"name":"Zakres","range":"(0,17 – 15,0) % (v/v)"},{"name":"Całkowita zawartość organicznie związanego tlenu (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość tlenowych związków organicznych\nZakres:\nZakres (0,17 – 15,0) % (v/v)\nCałkowita zawartość organicznie związanego tlenu (z obliczeń)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13132:2005","norm_bases":["PN-EN 13132:2005"],"lab_section":"Punkt Obsługi Laboratoryjnej w Lublinie PP7/1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Zawartość tlenowych związków organicznych\nZakres:\nZakres (0,17 – 15,0) % (v/v)\nCałkowita zawartość organicznie związanego tlenu (z obliczeń)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13132:2005 Paliwa ciekle: benzyna bezolowiowa Zawartosc tlenowych zwiazkow organicznych\nZakres:\nZakres (0,17 – 15,0) % (v/v)\nCalkowita zawartosc organicznie zwiazanego tlenu (z obliczen)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13132:2005","categories":["petro"],"row_index":509,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of oxygenated organic compounds","parameters_en":[{"name":"Range","range":"(0,17 – 15,0) % (v/v)"},{"name":"Total organically bound oxygen content (calculated)"}],"search_en":"Liquid fuels: unleaded petrol Content of oxygenated organic compounds Gas chromatography with flame ionization detection (GC-FID) Range Total organically bound oxygen content (calculated) PN-EN 13132:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Liquid fuels: unleaded petrol","parameters_zh":[{"name":"范围","range":"(0,17 – 15,0) % (v/v)"},{"name":"有机结合氧总量（由计算得出）"}],"search_zh":"液体燃料：无铅汽油 含氧有机化合物含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 有机结合氧总量（由计算得出） PN-EN 13132:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"液体燃料：无铅汽油","methodology_zh":"含氧有机化合物含量"},{"_id":"6a836fb9af14b9c0e7b1ed15","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki","methodology":"Gęstość w temperaturze 15°C","parameters":[{"name":"Zakres","range":"(800,0 – 900,0) kg/m3"}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"computed":[],"activity":"Gęstość w temperaturze 15°C\nZakres (800,0 – 900,0) kg/m3\nMetoda oscylacyjna","reference":"PN-EN ISO 12185:2024-08","norm_bases":["PN-EN ISO 12185:2024-08"],"lab_section":"Punkt Obsługi Laboratoryjnej w Lublinie PP7/1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki Gęstość w temperaturze 15°C\nZakres (800,0 – 900,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08 Paliwa ciekle: olej napedowy, olej opalowy lekki Gestosc w temperaturze 15°C\nZakres (800,0 – 900,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08","categories":["petro"],"row_index":510,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Density at 15°C","parameters_en":[{"name":"Range","range":"(800,0 – 900,0) kg/m3"}],"search_en":"Liquid fuels: diesel fuel, light fuel oil Density at 15°C Oscillation method Range PN-EN ISO 12185:2024-08","technique_en":"Oscillation method","test_object_en":"Liquid fuels: diesel fuel, light fuel oil","parameters_zh":[{"name":"范围","range":"(800,0 – 900,0) kg/m3"}],"search_zh":"液体燃料：柴油、轻质燃料油 15°C 时的密度 振荡法 范围 PN-EN ISO 12185:2024-08","technique_zh":"振荡法","test_object_zh":"液体燃料：柴油、轻质燃料油","methodology_zh":"15°C 时的密度"},{"_id":"6a836fb9af14b9c0e7b1ed16","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki","methodology":"Skład frakcyjny","parameters":[{"name":"Zakres","range":"(150,0 – 370,0) oC"}],"technique":"Metoda destylacyjna","techniques":["Metoda destylacyjna"],"computed":[],"activity":"Skład frakcyjny\nZakres (150,0 – 370,0) oC\nMetoda destylacyjna","reference":"PN-EN ISO 3405:2019-05","norm_bases":["PN-EN ISO 3405:2019-05"],"lab_section":"Punkt Obsługi Laboratoryjnej w Lublinie PP7/1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki Skład frakcyjny\nZakres (150,0 – 370,0) oC\nMetoda destylacyjna PN-EN ISO 3405:2019-05 Paliwa ciekle: olej napedowy, olej opalowy lekki Sklad frakcyjny\nZakres (150,0 – 370,0) oC\nMetoda destylacyjna PN-EN ISO 3405:2019-05","categories":["petro"],"row_index":511,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fractional composition","parameters_en":[{"name":"Range","range":"(150,0 – 370,0) oC"}],"search_en":"Liquid fuels: diesel fuel, light fuel oil Fractional composition Distillation method Range PN-EN ISO 3405:2019-05","technique_en":"Distillation method","test_object_en":"Liquid fuels: diesel fuel, light fuel oil","parameters_zh":[{"name":"范围","range":"(150,0 – 370,0) oC"}],"search_zh":"液体燃料：柴油、轻质燃料油 馏程组成 蒸馏法 范围 PN-EN ISO 3405:2019-05","technique_zh":"蒸馏法","methodology_zh":"馏程组成","test_object_zh":"液体燃料：柴油、轻质燃料油"},{"_id":"6a836fb9af14b9c0e7b1ed17","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki","methodology":"Zawartość zanieczyszczeń","parameters":[{"name":"Zakres","range":"(12,0 – 26,0) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość zanieczyszczeń\nZakres (12,0 – 26,0) mg/kg\nMetoda wagowa","reference":"PN-EN 12662-1:2024-11","norm_bases":["PN-EN 12662-1:2024-11"],"lab_section":"Punkt Obsługi Laboratoryjnej w Lublinie PP7/1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki Zawartość zanieczyszczeń\nZakres (12,0 – 26,0) mg/kg\nMetoda wagowa PN-EN 12662-1:2024-11 Paliwa ciekle: olej napedowy, olej opalowy lekki Zawartosc zanieczyszczen\nZakres (12,0 – 26,0) mg/kg\nMetoda wagowa PN-EN 12662-1:2024-11","categories":["petro"],"row_index":512,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Impurity content","parameters_en":[{"name":"Range","range":"(12,0 – 26,0) mg/kg"}],"search_en":"Liquid fuels: diesel fuel, light fuel oil Impurity content Gravimetric method Range PN-EN 12662-1:2024-11","technique_en":"Gravimetric method","test_object_en":"Liquid fuels: diesel fuel, light fuel oil","parameters_zh":[{"name":"范围","range":"(12,0 – 26,0) mg/kg"}],"search_zh":"液体燃料：柴油、轻质燃料油 杂质含量 重量法 范围 PN-EN 12662-1:2024-11","technique_zh":"重量法","methodology_zh":"杂质含量","test_object_zh":"液体燃料：柴油、轻质燃料油"},{"_id":"6a836fb9af14b9c0e7b1ed18","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki","methodology":"Zawartość wody","parameters":[{"name":"Zakres","range":"(0,003 – 0,100) %(m/m)"}],"technique":"Metoda miareczkowania kulometrycznego","techniques":["Metoda miareczkowania kulometrycznego"],"computed":[],"activity":"Zawartość wody\nZakres (0,003 – 0,100) %(m/m)\nMetoda miareczkowania kulometrycznego","reference":"PN-EN ISO 12937:2005+Ap1:2021-11","norm_bases":["PN-EN ISO 12937:2005+Ap1:2021-11"],"lab_section":"Punkt Obsługi Laboratoryjnej w Lublinie PP7/1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki Zawartość wody\nZakres (0,003 – 0,100) %(m/m)\nMetoda miareczkowania kulometrycznego PN-EN ISO 12937:2005+Ap1:2021-11 Paliwa ciekle: olej napedowy, olej opalowy lekki Zawartosc wody\nZakres (0,003 – 0,100) %(m/m)\nMetoda miareczkowania kulometrycznego PN-EN ISO 12937:2005+Ap1:2021-11","categories":["petro","water"],"row_index":513,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water content","parameters_en":[{"name":"Range","range":"(0,003 – 0,100) %(m/m)"}],"search_en":"Liquid fuels: diesel fuel, light fuel oil Water content Coulometric titration method Range PN-EN ISO 12937:2005+Ap1:2021-11","technique_en":"Coulometric titration method","test_object_en":"Liquid fuels: diesel fuel, light fuel oil","methodology_zh":"水分含量","parameters_zh":[{"name":"范围","range":"(0,003 – 0,100) %(m/m)"}],"search_zh":"液体燃料：柴油、轻质燃料油 水分含量 库仑滴定法 范围 PN-EN ISO 12937:2005+Ap1:2021-11","technique_zh":"库仑滴定法","test_object_zh":"液体燃料：柴油、轻质燃料油"},{"_id":"6a836fb9af14b9c0e7b1ed19","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki","methodology":"Temperatura zapłonu","parameters":[{"name":"Zakres","range":"(40,0 – 100,0) oC"}],"technique":"Metoda zamkniętego tygla Pensky’ego-Martensa","techniques":["Metoda zamkniętego tygla Pensky’ego-Martensa"],"computed":[],"activity":"Temperatura zapłonu\nZakres (40,0 – 100,0) oC\nMetoda zamkniętego tygla Pensky’ego-Martensa","reference":"PN-EN ISO 2719:2016-08+A1:2021-06","norm_bases":["PN-EN ISO 2719:2016-08+A1:2021-06"],"lab_section":"Punkt Obsługi Laboratoryjnej w Lublinie PP7/1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki Temperatura zapłonu\nZakres (40,0 – 100,0) oC\nMetoda zamkniętego tygla Pensky’ego-Martensa PN-EN ISO 2719:2016-08+A1:2021-06 Paliwa ciekle: olej napedowy, olej opalowy lekki Temperatura zaplonu\nZakres (40,0 – 100,0) oC\nMetoda zamknietego tygla Pensky’ego-Martensa PN-EN ISO 2719:2016-08+A1:2021-06","categories":["petro"],"row_index":514,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Flash point","parameters_en":[{"name":"Range","range":"(40,0 – 100,0) oC"}],"search_en":"Liquid fuels: diesel fuel, light fuel oil Flash point Pensky-Martens closed cup method Range PN-EN ISO 2719:2016-08+A1:2021-06","technique_en":"Pensky-Martens closed cup method","test_object_en":"Liquid fuels: diesel fuel, light fuel oil","parameters_zh":[{"name":"范围","range":"(40,0 – 100,0) oC"}],"search_zh":"液体燃料：柴油、轻质燃料油 闪点 宾斯基-马丁闭口杯法 范围 PN-EN ISO 2719:2016-08+A1:2021-06","methodology_zh":"闪点","test_object_zh":"液体燃料：柴油、轻质燃料油","technique_zh":"宾斯基-马丁闭口杯法"},{"_id":"6a836fb9af14b9c0e7b1ed1a","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki","methodology":"Zawartość siarki","parameters":[{"name":"Zakres","range":"(3,0 – 100) mg/kg"}],"technique":"Metoda fluorescencji w nadfiolecie","techniques":["Metoda fluorescencji w nadfiolecie"],"computed":[],"activity":"Zawartość siarki\nZakres (3,0 – 100) mg/kg\nMetoda fluorescencji w nadfiolecie","reference":"PN-EN ISO 20846:2020-03","norm_bases":["PN-EN ISO 20846:2020-03"],"lab_section":"Punkt Obsługi Laboratoryjnej w Lublinie PP7/1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki Zawartość siarki\nZakres (3,0 – 100) mg/kg\nMetoda fluorescencji w nadfiolecie PN-EN ISO 20846:2020-03 Paliwa ciekle: olej napedowy, olej opalowy lekki Zawartosc siarki\nZakres (3,0 – 100) mg/kg\nMetoda fluorescencji w nadfiolecie PN-EN ISO 20846:2020-03","categories":["petro"],"row_index":515,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfur content","parameters_en":[{"name":"Range","range":"(3,0 – 100) mg/kg"}],"search_en":"Liquid fuels: diesel fuel, light fuel oil Sulfur content Ultraviolet fluorescence method Range PN-EN ISO 20846:2020-03","technique_en":"Ultraviolet fluorescence method","test_object_en":"Liquid fuels: diesel fuel, light fuel oil","parameters_zh":[{"name":"范围","range":"(3,0 – 100) mg/kg"}],"search_zh":"液体燃料：柴油、轻质燃料油 硫含量 紫外荧光法 范围 PN-EN ISO 20846:2020-03","methodology_zh":"硫含量","technique_zh":"紫外荧光法","test_object_zh":"液体燃料：柴油、轻质燃料油"},{"_id":"6a836fb9af14b9c0e7b1ed1b","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy","methodology":"Indeks cetanowy (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Indeks cetanowy (z obliczeń)","reference":"PN-EN ISO 4264:2018-08","norm_bases":["PN-EN ISO 4264:2018-08"],"lab_section":"Punkt Obsługi Laboratoryjnej w Lublinie PP7/1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy Indeks cetanowy (z obliczeń) PN-EN ISO 4264:2018-08 Paliwa ciekle: olej napedowy Indeks cetanowy (z obliczen) PN-EN ISO 4264:2018-08","categories":["petro"],"row_index":516,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Cetane index (calculated)","search_en":"Liquid fuels: diesel fuel Cetane index (calculated) PN-EN ISO 4264:2018-08","test_object_en":"Liquid fuels: diesel fuel","search_zh":"液体燃料：柴油 十六烷指数（计算值） PN-EN ISO 4264:2018-08","test_object_zh":"液体燃料：柴油","methodology_zh":"十六烷指数（计算值）"},{"_id":"6a836fb9af14b9c0e7b1ed1c","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy","methodology":"Temperatura zablokowania zimnego filtra","parameters":[{"name":"[(- 33)","range":"(+5)] oC"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Temperatura zablokowania zimnego filtra\n[(- 33) (+5)] oC\nMetoda optyczna","reference":"PN-EN 116:2015-09","norm_bases":["PN-EN 116:2015-09"],"lab_section":"Punkt Obsługi Laboratoryjnej w Lublinie PP7/1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy Temperatura zablokowania zimnego filtra\n[(- 33) (+5)] oC\nMetoda optyczna PN-EN 116:2015-09 Paliwa ciekle: olej napedowy Temperatura zablokowania zimnego filtra\n[(- 33) (+5)] oC\nMetoda optyczna PN-EN 116:2015-09","categories":["petro"],"row_index":517,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Cold filter plugging point","parameters_en":[{"name":"[(- 33)","range":"(+5)] oC"}],"search_en":"Liquid fuels: diesel fuel Cold filter plugging point Optical method [(- 33) PN-EN 116:2015-09","technique_en":"Optical method","test_object_en":"Liquid fuels: diesel fuel","search_zh":"液体燃料：柴油 冷滤点 光学法 PN-EN 116:2015-09","technique_zh":"光学法","test_object_zh":"液体燃料：柴油","methodology_zh":"冷滤点"},{"_id":"6a836fb9af14b9c0e7b1ed1d","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy","methodology":"Zawartość estrów metylowych kwasów tłuszczowych (FAME)","parameters":[{"name":"Zakres","range":"(3,0 – 10,0) %(v/v)"}],"technique":"Metoda spektrometrii w zakresie podczerwieni IR","techniques":["Metoda spektrometrii w zakresie podczerwieni IR"],"computed":[],"activity":"Zawartość estrów metylowych kwasów tłuszczowych (FAME)\nZakres (3,0 – 10,0) %(v/v)\nMetoda spektrometrii w zakresie podczerwieni IR","reference":"PN-EN 14078:2014-06","norm_bases":["PN-EN 14078:2014-06"],"lab_section":"Punkt Obsługi Laboratoryjnej w Lublinie PP7/1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy Zawartość estrów metylowych kwasów tłuszczowych (FAME)\nZakres (3,0 – 10,0) %(v/v)\nMetoda spektrometrii w zakresie podczerwieni IR PN-EN 14078:2014-06 Paliwa ciekle: olej napedowy Zawartosc estrow metylowych kwasow tluszczowych (FAME)\nZakres (3,0 – 10,0) %(v/v)\nMetoda spektrometrii w zakresie podczerwieni IR PN-EN 14078:2014-06","categories":["petro"],"row_index":518,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fatty acid methyl esters (FAME) content","parameters_en":[{"name":"Range","range":"(3,0 – 10,0) %(v/v)"}],"search_en":"Liquid fuels: diesel fuel Fatty acid methyl esters (FAME) content Spectrometry method in the infrared range IR Range PN-EN 14078:2014-06","technique_en":"Spectrometry method in the infrared range IR","test_object_en":"Liquid fuels: diesel fuel","parameters_zh":[{"name":"范围","range":"(3,0 – 10,0) %(v/v)"}],"search_zh":"液体燃料：柴油 脂肪酸甲酯（FAME）含量 红外光谱法 IR 范围 PN-EN 14078:2014-06","test_object_zh":"液体燃料：柴油","technique_zh":"红外光谱法 IR","methodology_zh":"脂肪酸甲酯（FAME）含量"},{"_id":"6a836fb9af14b9c0e7b1ed1e","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Gęstość w temperaturze 15°C","parameters":[{"name":"Zakres","range":"(860,0 – 900,0) kg/m3"}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"computed":[],"activity":"Gęstość w temperaturze 15°C\nZakres (860,0 – 900,0) kg/m3\nMetoda oscylacyjna","reference":"PN-EN ISO 12185:2024-08","norm_bases":["PN-EN ISO 12185:2024-08"],"lab_section":"Punkt Obsługi Laboratoryjnej w Lublinie PP7/1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Gęstość w temperaturze 15°C\nZakres (860,0 – 900,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Gestosc w temperaturze 15°C\nZakres (860,0 – 900,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08","categories":["petro"],"row_index":519,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Density at 15°C","parameters_en":[{"name":"Range","range":"(860,0 – 900,0) kg/m3"}],"search_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME) Density at 15°C Oscillation method Range PN-EN ISO 12185:2024-08","technique_en":"Oscillation method","test_object_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME)","parameters_zh":[{"name":"范围","range":"(860,0 – 900,0) kg/m3"}],"search_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME） 15°C 时的密度 振荡法 范围 PN-EN ISO 12185:2024-08","technique_zh":"振荡法","test_object_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME）","methodology_zh":"15°C 时的密度"},{"_id":"6a836fb9af14b9c0e7b1ed1f","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość wody","parameters":[{"name":"Zakres","range":"(0,003 – 0,100) %(m/m)"}],"technique":"Metoda miareczkowania kulometrycznego","techniques":["Metoda miareczkowania kulometrycznego"],"computed":[],"activity":"Zawartość wody\nZakres (0,003 – 0,100) %(m/m)\nMetoda miareczkowania kulometrycznego","reference":"PN-EN ISO 12937:2005+Ap1:2021-11","norm_bases":["PN-EN ISO 12937:2005+Ap1:2021-11"],"lab_section":"Punkt Obsługi Laboratoryjnej w Lublinie PP7/1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Zawartość wody\nZakres (0,003 – 0,100) %(m/m)\nMetoda miareczkowania kulometrycznego PN-EN ISO 12937:2005+Ap1:2021-11 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Zawartosc wody\nZakres (0,003 – 0,100) %(m/m)\nMetoda miareczkowania kulometrycznego PN-EN ISO 12937:2005+Ap1:2021-11","categories":["petro","water"],"row_index":520,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water content","parameters_en":[{"name":"Range","range":"(0,003 – 0,100) %(m/m)"}],"search_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME) Water content Coulometric titration method Range PN-EN ISO 12937:2005+Ap1:2021-11","technique_en":"Coulometric titration method","test_object_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME)","methodology_zh":"水分含量","parameters_zh":[{"name":"范围","range":"(0,003 – 0,100) %(m/m)"}],"search_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME） 水分含量 库仑滴定法 范围 PN-EN ISO 12937:2005+Ap1:2021-11","technique_zh":"库仑滴定法","test_object_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME）"},{"_id":"6a836fb9af14b9c0e7b1ed20","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Temperatura zablokowania zimnego filtra","parameters":[{"name":"[(- 25)","range":"(-5)] oC"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Temperatura zablokowania zimnego filtra\n[(- 25) (-5)] oC\nMetoda optyczna","reference":"PN-EN 116:2015-09","norm_bases":["PN-EN 116:2015-09"],"lab_section":"Punkt Obsługi Laboratoryjnej w Lublinie PP7/1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Temperatura zablokowania zimnego filtra\n[(- 25) (-5)] oC\nMetoda optyczna PN-EN 116:2015-09 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Temperatura zablokowania zimnego filtra\n[(- 25) (-5)] oC\nMetoda optyczna PN-EN 116:2015-09","categories":["petro"],"row_index":521,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Cold filter plugging point","parameters_en":[{"name":"[(- 25)","range":"(-5)] oC"}],"search_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME) Cold filter plugging point Optical method [(- 25) PN-EN 116:2015-09","technique_en":"Optical method","test_object_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME)","search_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME） 冷滤点 光学法 PN-EN 116:2015-09","technique_zh":"光学法","test_object_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME）","methodology_zh":"冷滤点"},{"_id":"6a836fb9af14b9c0e7b1ed21","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Skłonność do blokowania filtra po wychładzaniu","parameters":[{"name":"Zakres","range":"(30 – 360) s"}],"technique":"Metoda filtracji po wychłodzeniu","techniques":["Metoda filtracji po wychłodzeniu"],"computed":[],"activity":"Skłonność do blokowania filtra po wychładzaniu\nZakres (30 – 360) s\nMetoda filtracji po wychłodzeniu","reference":"ASTM D 7501-22","norm_bases":["ASTM D 7501-22"],"lab_section":"Punkt Obsługi Laboratoryjnej w Lublinie PP7/1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Skłonność do blokowania filtra po wychładzaniu\nZakres (30 – 360) s\nMetoda filtracji po wychłodzeniu ASTM D 7501-22 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Sklonnosc do blokowania filtra po wychladzaniu\nZakres (30 – 360) s\nMetoda filtracji po wychlodzeniu ASTM D 7501-22","categories":["petro"],"row_index":522,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Tendency to plug the filter after cooling","parameters_en":[{"name":"Range","range":"(30 – 360) s"}],"search_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME) Tendency to plug the filter after cooling Filtration after cooling method Range ASTM D 7501-22","technique_en":"Filtration after cooling method","test_object_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME)","parameters_zh":[{"name":"范围","range":"(30 – 360) s"}],"search_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME） 冷却后堵塞滤器的倾向 范围 ASTM D 7501-22","test_object_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME）","methodology_zh":"冷却后堵塞滤器的倾向"},{"_id":"6a836fb9af14b9c0e7b1ed22","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość zanieczyszczeń","parameters":[{"name":"Zakres","range":"(5,0 – 27,0) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość zanieczyszczeń\nZakres (5,0 – 27,0) mg/kg\nMetoda wagowa","reference":"PN-EN 12662-2:2024-11","norm_bases":["PN-EN 12662-2:2024-11"],"lab_section":"Punkt Obsługi Laboratoryjnej w Lublinie PP7/1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Zawartość zanieczyszczeń\nZakres (5,0 – 27,0) mg/kg\nMetoda wagowa PN-EN 12662-2:2024-11 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Zawartosc zanieczyszczen\nZakres (5,0 – 27,0) mg/kg\nMetoda wagowa PN-EN 12662-2:2024-11","categories":["petro"],"row_index":523,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Impurity content","parameters_en":[{"name":"Range","range":"(5,0 – 27,0) mg/kg"}],"search_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME) Impurity content Gravimetric method Range PN-EN 12662-2:2024-11","technique_en":"Gravimetric method","test_object_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME)","parameters_zh":[{"name":"范围","range":"(5,0 – 27,0) mg/kg"}],"search_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME） 杂质含量 重量法 范围 PN-EN 12662-2:2024-11","technique_zh":"重量法","methodology_zh":"杂质含量","test_object_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME）"},{"_id":"6a836fb9af14b9c0e7b1ed23","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, olej opałowy lekki, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Pobieranie próbek ze zbiornika do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek ze zbiornika do badań chemicznych i fizycznych","reference":"PN-EN ISO 3170:2025-12 z wyłączeniem 8.3.1.3 - 8.3.1.6, 8.3.1.8, 8.3.2, 8.7 - 8.9, 9.8, 10.6, 10.7","norm_bases":["PN-EN ISO 3170:2025-12 z wyłączeniem 8.3.1.3 - 8.3.1.6, 8.3.1.8, 8.3.2, 8.7 - 8.9, 9.8, 10.6, 10.7"],"lab_section":"Punkt Obsługi Laboratoryjnej w Olsztynie PP7/2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, olej opałowy lekki, biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Pobieranie próbek ze zbiornika do badań chemicznych i fizycznych PN-EN ISO 3170:2025-12 z wyłączeniem 8.3.1.3 - 8.3.1.6, 8.3.1.8, 8.3.2, 8.7 - 8.9, 9.8, 10.6, 10.7 Paliwa ciekle: olej napedowy, benzyna bezolowiowa, olej opalowy lekki, biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Pobieranie probek ze zbiornika do badan chemicznych i fizycznych PN-EN ISO 3170:2025-12 z wylaczeniem 8.3.1.3 - 8.3.1.6, 8.3.1.8, 8.3.2, 8.7 - 8.9, 9.8, 10.6, 10.7","categories":["petro"],"row_index":524,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling from a tank for chemical and physical testing","search_en":"Liquid fuels: diesel fuel, unleaded petrol, light fuel oil, liquid biofuels: fatty acid methyl esters (FAME) Sampling from a tank for chemical and physical testing PN-EN ISO 3170:2025-12 z wyłączeniem 8.3.1.3 - 8.3.1.6, 8.3.1.8, 8.3.2, 8.7 - 8.9, 9.8, 10.6, 10.7","test_object_en":"Liquid fuels: diesel fuel, unleaded petrol, light fuel oil, liquid biofuels: fatty acid methyl esters (FAME)"},{"_id":"6a836fb9af14b9c0e7b1ed24","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, olej opałowy lekki","methodology":"Zawartość siarki","parameters":[{"name":"Zakres","range":"(3,0 – 50) mg/kg"}],"technique":"Metoda fluorescencji w nadfiolecie","techniques":["Metoda fluorescencji w nadfiolecie"],"computed":[],"activity":"Zawartość siarki\nZakres (3,0 – 50) mg/kg\nMetoda fluorescencji w nadfiolecie","reference":"PN-EN ISO 20846:2020-03","norm_bases":["PN-EN ISO 20846:2020-03"],"lab_section":"Punkt Obsługi Laboratoryjnej w Olsztynie PP7/2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, olej opałowy lekki Zawartość siarki\nZakres (3,0 – 50) mg/kg\nMetoda fluorescencji w nadfiolecie PN-EN ISO 20846:2020-03 Paliwa ciekle: olej napedowy, benzyna bezolowiowa, olej opalowy lekki Zawartosc siarki\nZakres (3,0 – 50) mg/kg\nMetoda fluorescencji w nadfiolecie PN-EN ISO 20846:2020-03","categories":["petro"],"row_index":525,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfur content","parameters_en":[{"name":"Range","range":"(3,0 – 50) mg/kg"}],"search_en":"Liquid fuels: diesel fuel, unleaded petrol, light fuel oil Sulfur content Ultraviolet fluorescence method Range PN-EN ISO 20846:2020-03","technique_en":"Ultraviolet fluorescence method","test_object_en":"Liquid fuels: diesel fuel, unleaded petrol, light fuel oil","parameters_zh":[{"name":"范围","range":"(3,0 – 50) mg/kg"}],"search_zh":"硫含量 紫外荧光法 范围 PN-EN ISO 20846:2020-03","methodology_zh":"硫含量","technique_zh":"紫外荧光法"},{"_id":"6a836fb9af14b9c0e7b1ed25","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, olej opałowy lekki","methodology":"Gęstość w temperaturze 15°C","parameters":[{"name":"Zakres","range":"(700,0 – 900,0) kg/m3"}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"computed":[],"activity":"Gęstość w temperaturze 15°C\nZakres (700,0 – 900,0) kg/m3\nMetoda oscylacyjna","reference":"PN-EN ISO 12185:2024-08","norm_bases":["PN-EN ISO 12185:2024-08"],"lab_section":"Punkt Obsługi Laboratoryjnej w Olsztynie PP7/2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, olej opałowy lekki Gęstość w temperaturze 15°C\nZakres (700,0 – 900,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08 Paliwa ciekle: olej napedowy, benzyna bezolowiowa, olej opalowy lekki Gestosc w temperaturze 15°C\nZakres (700,0 – 900,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08","categories":["petro"],"row_index":526,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Density at 15°C","parameters_en":[{"name":"Range","range":"(700,0 – 900,0) kg/m3"}],"search_en":"Liquid fuels: diesel fuel, unleaded petrol, light fuel oil Density at 15°C Oscillation method Range PN-EN ISO 12185:2024-08","technique_en":"Oscillation method","test_object_en":"Liquid fuels: diesel fuel, unleaded petrol, light fuel oil","parameters_zh":[{"name":"范围","range":"(700,0 – 900,0) kg/m3"}],"search_zh":"15°C 时的密度 振荡法 范围 PN-EN ISO 12185:2024-08","technique_zh":"振荡法","methodology_zh":"15°C 时的密度"},{"_id":"6a836fb9af14b9c0e7b1ed26","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, olej opałowy lekki","methodology":"Skład frakcyjny","parameters":[{"name":"Zakres","range":"(30,0 – 370,0) oC"}],"technique":"Metoda destylacyjna","techniques":["Metoda destylacyjna"],"computed":[],"activity":"Skład frakcyjny\nZakres (30,0 – 370,0) oC\nMetoda destylacyjna","reference":"PN-EN ISO 3405:2019-05","norm_bases":["PN-EN ISO 3405:2019-05"],"lab_section":"Punkt Obsługi Laboratoryjnej w Olsztynie PP7/2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, olej opałowy lekki Skład frakcyjny\nZakres (30,0 – 370,0) oC\nMetoda destylacyjna PN-EN ISO 3405:2019-05 Paliwa ciekle: olej napedowy, benzyna bezolowiowa, olej opalowy lekki Sklad frakcyjny\nZakres (30,0 – 370,0) oC\nMetoda destylacyjna PN-EN ISO 3405:2019-05","categories":["petro"],"row_index":527,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fractional composition","parameters_en":[{"name":"Range","range":"(30,0 – 370,0) oC"}],"search_en":"Liquid fuels: diesel fuel, unleaded petrol, light fuel oil Fractional composition Distillation method Range PN-EN ISO 3405:2019-05","technique_en":"Distillation method","test_object_en":"Liquid fuels: diesel fuel, unleaded petrol, light fuel oil","parameters_zh":[{"name":"范围","range":"(30,0 – 370,0) oC"}],"search_zh":"馏程组成 蒸馏法 范围 PN-EN ISO 3405:2019-05","technique_zh":"蒸馏法","methodology_zh":"馏程组成"},{"_id":"6a836fb9af14b9c0e7b1ed27","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy","methodology":"Temperatura zablokowania zimnego filtra","parameters":[{"name":"[","range":"(-40) – (0,0)]°C"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Temperatura zablokowania zimnego filtra\n[ (-40) – (0,0)]°C\nMetoda optyczna","reference":"PN-EN 116:2015-09","norm_bases":["PN-EN 116:2015-09"],"lab_section":"Punkt Obsługi Laboratoryjnej w Olsztynie PP7/2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy Temperatura zablokowania zimnego filtra\n[ (-40) – (0,0)]°C\nMetoda optyczna PN-EN 116:2015-09 Paliwa ciekle: olej napedowy Temperatura zablokowania zimnego filtra\n[ (-40) – (0,0)]°C\nMetoda optyczna PN-EN 116:2015-09","categories":["petro"],"row_index":528,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Cold filter plugging point","parameters_en":[{"name":"[","range":"(-40) – (0,0)]°C"}],"search_en":"Liquid fuels: diesel fuel Cold filter plugging point Optical method [ PN-EN 116:2015-09","technique_en":"Optical method","test_object_en":"Liquid fuels: diesel fuel","search_zh":"液体燃料：柴油 冷滤点 光学法 PN-EN 116:2015-09","technique_zh":"光学法","test_object_zh":"液体燃料：柴油","methodology_zh":"冷滤点"},{"_id":"6a836fb9af14b9c0e7b1ed28","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy","methodology":"Indeks cetanowy (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Indeks cetanowy (z obliczeń)","reference":"PN-EN ISO 4264:2018-08","norm_bases":["PN-EN ISO 4264:2018-08"],"lab_section":"Punkt Obsługi Laboratoryjnej w Olsztynie PP7/2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy Indeks cetanowy (z obliczeń) PN-EN ISO 4264:2018-08 Paliwa ciekle: olej napedowy Indeks cetanowy (z obliczen) PN-EN ISO 4264:2018-08","categories":["petro"],"row_index":529,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Cetane index (calculated)","search_en":"Liquid fuels: diesel fuel Cetane index (calculated) PN-EN ISO 4264:2018-08","test_object_en":"Liquid fuels: diesel fuel","search_zh":"液体燃料：柴油 十六烷指数（计算值） PN-EN ISO 4264:2018-08","test_object_zh":"液体燃料：柴油","methodology_zh":"十六烷指数（计算值）"},{"_id":"6a836fb9af14b9c0e7b1ed29","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy","methodology":"Zawartość zanieczyszczeń","parameters":[{"name":"Zakres","range":"(12,0 – 26,0) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość zanieczyszczeń\nZakres (12,0 – 26,0) mg/kg\nMetoda wagowa","reference":"PN-EN 12662-1:2024-11","norm_bases":["PN-EN 12662-1:2024-11"],"lab_section":"Punkt Obsługi Laboratoryjnej w Olsztynie PP7/2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy Zawartość zanieczyszczeń\nZakres (12,0 – 26,0) mg/kg\nMetoda wagowa PN-EN 12662-1:2024-11 Paliwa ciekle: olej napedowy Zawartosc zanieczyszczen\nZakres (12,0 – 26,0) mg/kg\nMetoda wagowa PN-EN 12662-1:2024-11","categories":["petro"],"row_index":530,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Impurity content","parameters_en":[{"name":"Range","range":"(12,0 – 26,0) mg/kg"}],"search_en":"Liquid fuels: diesel fuel Impurity content Gravimetric method Range PN-EN 12662-1:2024-11","technique_en":"Gravimetric method","test_object_en":"Liquid fuels: diesel fuel","parameters_zh":[{"name":"范围","range":"(12,0 – 26,0) mg/kg"}],"search_zh":"液体燃料：柴油 杂质含量 重量法 范围 PN-EN 12662-1:2024-11","technique_zh":"重量法","test_object_zh":"液体燃料：柴油","methodology_zh":"杂质含量"},{"_id":"6a836fb9af14b9c0e7b1ed2a","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy","methodology":"Temperatura mętnienia","parameters":[{"name":"[(- 20,0)","range":"(0,0)] oC"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Temperatura mętnienia\n[(- 20,0) (0,0)] oC\nMetoda optyczna","reference":"ASTM D 5772-21","norm_bases":["ASTM D 5772-21"],"lab_section":"Punkt Obsługi Laboratoryjnej w Olsztynie PP7/2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy Temperatura mętnienia\n[(- 20,0) (0,0)] oC\nMetoda optyczna ASTM D 5772-21 Paliwa ciekle: olej napedowy Temperatura metnienia\n[(- 20,0) (0,0)] oC\nMetoda optyczna ASTM D 5772-21","categories":["petro"],"row_index":531,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Cloud point","parameters_en":[{"name":"[(- 20,0)","range":"(0,0)] oC"}],"search_en":"Liquid fuels: diesel fuel Cloud point Optical method [(- 20,0) ASTM D 5772-21","technique_en":"Optical method","test_object_en":"Liquid fuels: diesel fuel","search_zh":"液体燃料：柴油 浊点 光学法 ASTM D 5772-21","technique_zh":"光学法","test_object_zh":"液体燃料：柴油","methodology_zh":"浊点"},{"_id":"6a836fb9af14b9c0e7b1ed2b","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki","methodology":"Temperatura zapłonu","parameters":[{"name":"Zakres","range":"(40,0 – 90,0) oC"}],"technique":"Metoda zamkniętego tygla Pensky’ego-Martensa","techniques":["Metoda zamkniętego tygla Pensky’ego-Martensa"],"computed":[],"activity":"Temperatura zapłonu\nZakres (40,0 – 90,0) oC\nMetoda zamkniętego tygla Pensky’ego-Martensa","reference":"PN-EN ISO 2719:2016-08+A1:2021-06","norm_bases":["PN-EN ISO 2719:2016-08+A1:2021-06"],"lab_section":"Punkt Obsługi Laboratoryjnej w Olsztynie PP7/2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki Temperatura zapłonu\nZakres (40,0 – 90,0) oC\nMetoda zamkniętego tygla Pensky’ego-Martensa PN-EN ISO 2719:2016-08+A1:2021-06 Paliwa ciekle: olej napedowy, olej opalowy lekki Temperatura zaplonu\nZakres (40,0 – 90,0) oC\nMetoda zamknietego tygla Pensky’ego-Martensa PN-EN ISO 2719:2016-08+A1:2021-06","categories":["petro"],"row_index":532,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Flash point","parameters_en":[{"name":"Range","range":"(40,0 – 90,0) oC"}],"search_en":"Liquid fuels: diesel fuel, light fuel oil Flash point Pensky-Martens closed cup method Range PN-EN ISO 2719:2016-08+A1:2021-06","technique_en":"Pensky-Martens closed cup method","test_object_en":"Liquid fuels: diesel fuel, light fuel oil","parameters_zh":[{"name":"范围","range":"(40,0 – 90,0) oC"}],"search_zh":"液体燃料：柴油、轻质燃料油 闪点 宾斯基-马丁闭口杯法 范围 PN-EN ISO 2719:2016-08+A1:2021-06","methodology_zh":"闪点","test_object_zh":"液体燃料：柴油、轻质燃料油","technique_zh":"宾斯基-马丁闭口杯法"},{"_id":"6a836fb9af14b9c0e7b1ed2c","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki","methodology":"Zawartość wody","parameters":[{"name":"Zakres","range":"(30 – 1000) mg/kg"}],"technique":"Metoda miareczkowania kulometrycznego","techniques":["Metoda miareczkowania kulometrycznego"],"computed":[],"activity":"Zawartość wody\nZakres (30 – 1000) mg/kg\nMetoda miareczkowania kulometrycznego","reference":"PN-EN ISO 12937:2005+Ap1:2021-11","norm_bases":["PN-EN ISO 12937:2005+Ap1:2021-11"],"lab_section":"Punkt Obsługi Laboratoryjnej w Olsztynie PP7/2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki Zawartość wody\nZakres (30 – 1000) mg/kg\nMetoda miareczkowania kulometrycznego PN-EN ISO 12937:2005+Ap1:2021-11 Paliwa ciekle: olej napedowy, olej opalowy lekki Zawartosc wody\nZakres (30 – 1000) mg/kg\nMetoda miareczkowania kulometrycznego PN-EN ISO 12937:2005+Ap1:2021-11","categories":["petro","water"],"row_index":533,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water content","parameters_en":[{"name":"Range","range":"(30 – 1000) mg/kg"}],"search_en":"Liquid fuels: diesel fuel, light fuel oil Water content Coulometric titration method Range PN-EN ISO 12937:2005+Ap1:2021-11","technique_en":"Coulometric titration method","test_object_en":"Liquid fuels: diesel fuel, light fuel oil","methodology_zh":"水分含量","parameters_zh":[{"name":"范围","range":"(30 – 1000) mg/kg"}],"search_zh":"液体燃料：柴油、轻质燃料油 水分含量 库仑滴定法 范围 PN-EN ISO 12937:2005+Ap1:2021-11","technique_zh":"库仑滴定法","test_object_zh":"液体燃料：柴油、轻质燃料油"},{"_id":"6a836fb9af14b9c0e7b1ed2d","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Zawartość tlenowych związków organicznych","parameters":[{"name":"Zakres","range":"(0,17 – 15,0) %(v/v)"},{"name":"Całkowita zawartość organicznie związanego tlenu (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość tlenowych związków organicznych\nZakres:\nZakres (0,17 – 15,0) %(v/v)\nCałkowita zawartość organicznie związanego tlenu (z obliczeń)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13132:2005","norm_bases":["PN-EN 13132:2005"],"lab_section":"Punkt Obsługi Laboratoryjnej w Olsztynie PP7/2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Zawartość tlenowych związków organicznych\nZakres:\nZakres (0,17 – 15,0) %(v/v)\nCałkowita zawartość organicznie związanego tlenu (z obliczeń)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13132:2005 Paliwa ciekle: benzyna bezolowiowa Zawartosc tlenowych zwiazkow organicznych\nZakres:\nZakres (0,17 – 15,0) %(v/v)\nCalkowita zawartosc organicznie zwiazanego tlenu (z obliczen)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13132:2005","categories":["petro"],"row_index":534,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of oxygenated organic compounds","parameters_en":[{"name":"Range","range":"(0,17 – 15,0) %(v/v)"},{"name":"Total organically bound oxygen content (calculated)"}],"search_en":"Liquid fuels: unleaded petrol Content of oxygenated organic compounds Gas chromatography with flame ionization detection (GC-FID) Range Total organically bound oxygen content (calculated) PN-EN 13132:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Liquid fuels: unleaded petrol","parameters_zh":[{"name":"范围","range":"(0,17 – 15,0) %(v/v)"},{"name":"有机结合氧总量（由计算得出）"}],"search_zh":"液体燃料：无铅汽油 含氧有机化合物含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 有机结合氧总量（由计算得出） PN-EN 13132:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"液体燃料：无铅汽油","methodology_zh":"含氧有机化合物含量"},{"_id":"6a836fb9af14b9c0e7b1ed2e","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Prężność par nasyconych powietrzem","parameters":[{"name":"Zakres","range":"(40,0 – 106,0) kPa"}],"technique":"Metoda mini Reid","techniques":["Metoda mini Reid"],"computed":[],"activity":"Prężność par nasyconych powietrzem\nZakres (40,0 – 106,0) kPa\nMetoda mini Reid","reference":"PN-EN 13016-1:2024-11","norm_bases":["PN-EN 13016-1:2024-11"],"lab_section":"Punkt Obsługi Laboratoryjnej w Olsztynie PP7/2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Prężność par nasyconych powietrzem\nZakres (40,0 – 106,0) kPa\nMetoda mini Reid PN-EN 13016-1:2024-11 Paliwa ciekle: benzyna bezolowiowa Preznosc par nasyconych powietrzem\nZakres (40,0 – 106,0) kPa\nMetoda mini Reid PN-EN 13016-1:2024-11","categories":["petro","environment"],"row_index":535,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air saturated vapour pressure","parameters_en":[{"name":"Range","range":"(40,0 – 106,0) kPa"}],"search_en":"Liquid fuels: unleaded petrol Air saturated vapour pressure Mini Reid method Range PN-EN 13016-1:2024-11","technique_en":"Mini Reid method","test_object_en":"Liquid fuels: unleaded petrol","parameters_zh":[{"name":"范围","range":"(40,0 – 106,0) kPa"}],"search_zh":"液体燃料：无铅汽油 空气饱和蒸气压 迷你雷德法 范围 PN-EN 13016-1:2024-11","test_object_zh":"液体燃料：无铅汽油","technique_zh":"迷你雷德法","methodology_zh":"空气饱和蒸气压"},{"_id":"6a836fb9af14b9c0e7b1ed2f","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Indeks lotności (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Indeks lotności (z obliczeń)","reference":"PN-EN 228+A1:2017-06 p. 5.5.2","norm_bases":["PN-EN 228+A1:2017-06 p. 5.5.2"],"lab_section":"Punkt Obsługi Laboratoryjnej w Olsztynie PP7/2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Indeks lotności (z obliczeń) PN-EN 228+A1:2017-06 p. 5.5.2 Paliwa ciekle: benzyna bezolowiowa Indeks lotnosci (z obliczen) PN-EN 228+A1:2017-06 p. 5.5.2","categories":["petro"],"row_index":536,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Volatility index (calculated)","search_en":"Liquid fuels: unleaded petrol Volatility index (calculated) PN-EN 228+A1:2017-06 p. 5.5.2","test_object_en":"Liquid fuels: unleaded petrol","search_zh":"液体燃料：无铅汽油 挥发性指数（计算值） PN-EN 228+A1:2017-06 p. 5.5.2","test_object_zh":"液体燃料：无铅汽油","methodology_zh":"挥发性指数（计算值）"},{"_id":"6a836fb9af14b9c0e7b1ed30","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Liczba oktanowa LOM","parameters":[{"name":"Zakres","range":"80,0 – 90,0"}],"technique":"Metoda silnikowa","techniques":["Metoda silnikowa"],"computed":[],"activity":"Liczba oktanowa LOM\nZakres 80,0 – 90,0\nMetoda silnikowa","reference":"PN-EN ISO 5163:2014-08","norm_bases":["PN-EN ISO 5163:2014-08"],"lab_section":"Punkt Obsługi Laboratoryjnej w Olsztynie PP7/2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Liczba oktanowa LOM\nZakres 80,0 – 90,0\nMetoda silnikowa PN-EN ISO 5163:2014-08 Paliwa ciekle: benzyna bezolowiowa Liczba oktanowa LOM\nZakres 80,0 – 90,0\nMetoda silnikowa PN-EN ISO 5163:2014-08","categories":["petro"],"row_index":537,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Motor octane number MON","parameters_en":[{"name":"Range","range":"80,0 – 90,0"}],"search_en":"Liquid fuels: unleaded petrol Motor octane number MON Motor method Range PN-EN ISO 5163:2014-08","technique_en":"Motor method","test_object_en":"Liquid fuels: unleaded petrol","parameters_zh":[{"name":"范围","range":"80,0 – 90,0"}],"search_zh":"液体燃料：无铅汽油 马达法辛烷值 MON 发动机法 范围 PN-EN ISO 5163:2014-08","technique_zh":"发动机法","test_object_zh":"液体燃料：无铅汽油","methodology_zh":"马达法辛烷值 MON"},{"_id":"6a836fb9af14b9c0e7b1ed31","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, biopaliwa ciekłe: olej napędowy z FAME","methodology":"Zawartość estrów metylowych kwasów tłuszczowych","parameters":[{"name":"Zakres","range":"(3,0 – 20,0) %(v/v)"}],"technique":"Metoda spektrometrii w zakresie podczerwieni IR","techniques":["Metoda spektrometrii w zakresie podczerwieni IR"],"computed":[],"activity":"Zawartość estrów metylowych kwasów tłuszczowych\nZakres (3,0 – 20,0) %(v/v)\nMetoda spektrometrii w zakresie podczerwieni IR","reference":"PN-EN 14078:2014-06","norm_bases":["PN-EN 14078:2014-06"],"lab_section":"Punkt Obsługi Laboratoryjnej w Olsztynie PP7/2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, biopaliwa ciekłe: olej napędowy z FAME Zawartość estrów metylowych kwasów tłuszczowych\nZakres (3,0 – 20,0) %(v/v)\nMetoda spektrometrii w zakresie podczerwieni IR PN-EN 14078:2014-06 Paliwa ciekle: olej napedowy, biopaliwa ciekle: olej napedowy z FAME Zawartosc estrow metylowych kwasow tluszczowych\nZakres (3,0 – 20,0) %(v/v)\nMetoda spektrometrii w zakresie podczerwieni IR PN-EN 14078:2014-06","categories":["petro"],"row_index":538,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fatty acid methyl ester content","parameters_en":[{"name":"Range","range":"(3,0 – 20,0) %(v/v)"}],"search_en":"Liquid fuels: diesel fuel, liquid biofuels: diesel fuel with FAME Fatty acid methyl ester content Spectrometry method in the infrared range IR Range PN-EN 14078:2014-06","technique_en":"Spectrometry method in the infrared range IR","test_object_en":"Liquid fuels: diesel fuel, liquid biofuels: diesel fuel with FAME","parameters_zh":[{"name":"范围","range":"(3,0 – 20,0) %(v/v)"}],"search_zh":"液体燃料：柴油；液体生物燃料：含 FAME 的柴油 脂肪酸甲酯含量 红外光谱法 IR 范围 PN-EN 14078:2014-06","technique_zh":"红外光谱法 IR","methodology_zh":"脂肪酸甲酯含量","test_object_zh":"液体燃料：柴油；液体生物燃料：含 FAME 的柴油"},{"_id":"6a836fb9af14b9c0e7b1ed32","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Gęstość w temperaturze 15°C","parameters":[{"name":"Zakres","range":"(800,0 – 900,0) kg/m3"}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"computed":[],"activity":"Gęstość w temperaturze 15°C\nZakres (800,0 – 900,0) kg/m3\nMetoda oscylacyjna","reference":"PN-EN ISO 12185:2024-08","norm_bases":["PN-EN ISO 12185:2024-08"],"lab_section":"Punkt Obsługi Laboratoryjnej w Olsztynie PP7/2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Gęstość w temperaturze 15°C\nZakres (800,0 – 900,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Gestosc w temperaturze 15°C\nZakres (800,0 – 900,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08","categories":["petro"],"row_index":539,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Density at 15°C","parameters_en":[{"name":"Range","range":"(800,0 – 900,0) kg/m3"}],"search_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME) Density at 15°C Oscillation method Range PN-EN ISO 12185:2024-08","technique_en":"Oscillation method","test_object_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME)","parameters_zh":[{"name":"范围","range":"(800,0 – 900,0) kg/m3"}],"search_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME） 15°C 时的密度 振荡法 范围 PN-EN ISO 12185:2024-08","technique_zh":"振荡法","test_object_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME）","methodology_zh":"15°C 时的密度"},{"_id":"6a836fb9af14b9c0e7b1ed33","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość wody","parameters":[{"name":"Zakres","range":"(30 – 1000) mg/kg"}],"technique":"Metoda miareczkowania kulometrycznego","techniques":["Metoda miareczkowania kulometrycznego"],"computed":[],"activity":"Zawartość wody\nZakres (30 – 1000) mg/kg\nMetoda miareczkowania kulometrycznego","reference":"PN-EN ISO 12937:2005+Ap1:2021-11","norm_bases":["PN-EN ISO 12937:2005+Ap1:2021-11"],"lab_section":"Punkt Obsługi Laboratoryjnej w Olsztynie PP7/2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Zawartość wody\nZakres (30 – 1000) mg/kg\nMetoda miareczkowania kulometrycznego PN-EN ISO 12937:2005+Ap1:2021-11 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Zawartosc wody\nZakres (30 – 1000) mg/kg\nMetoda miareczkowania kulometrycznego PN-EN ISO 12937:2005+Ap1:2021-11","categories":["petro","water"],"row_index":540,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water content","parameters_en":[{"name":"Range","range":"(30 – 1000) mg/kg"}],"search_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME) Water content Coulometric titration method Range PN-EN ISO 12937:2005+Ap1:2021-11","technique_en":"Coulometric titration method","test_object_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME)","methodology_zh":"水分含量","parameters_zh":[{"name":"范围","range":"(30 – 1000) mg/kg"}],"search_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME） 水分含量 库仑滴定法 范围 PN-EN ISO 12937:2005+Ap1:2021-11","technique_zh":"库仑滴定法","test_object_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME）"},{"_id":"6a836fb9af14b9c0e7b1ed34","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Temperatura mętnienia","parameters":[{"name":"[(- 20,0)","range":"(0,0)] oC"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Temperatura mętnienia\n[(- 20,0) (0,0)] oC\nMetoda optyczna","reference":"ASTM D 5772-21","norm_bases":["ASTM D 5772-21"],"lab_section":"Punkt Obsługi Laboratoryjnej w Olsztynie PP7/2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Temperatura mętnienia\n[(- 20,0) (0,0)] oC\nMetoda optyczna ASTM D 5772-21 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Temperatura metnienia\n[(- 20,0) (0,0)] oC\nMetoda optyczna ASTM D 5772-21","categories":["petro"],"row_index":541,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Cloud point","parameters_en":[{"name":"[(- 20,0)","range":"(0,0)] oC"}],"search_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME) Cloud point Optical method [(- 20,0) ASTM D 5772-21","technique_en":"Optical method","test_object_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME)","search_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME） 浊点 光学法 ASTM D 5772-21","technique_zh":"光学法","test_object_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME）","methodology_zh":"浊点"},{"_id":"6a836fb9af14b9c0e7b1ed35","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Temperatura zablokowania zimnego filtra","parameters":[{"name":"[(-40)","range":"(0,0)] °C"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Temperatura zablokowania zimnego filtra\n[(-40) (0,0)] °C\nMetoda optyczna","reference":"PN-EN 116:2015-09","norm_bases":["PN-EN 116:2015-09"],"lab_section":"Punkt Obsługi Laboratoryjnej w Olsztynie PP7/2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Temperatura zablokowania zimnego filtra\n[(-40) (0,0)] °C\nMetoda optyczna PN-EN 116:2015-09 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Temperatura zablokowania zimnego filtra\n[(-40) (0,0)] °C\nMetoda optyczna PN-EN 116:2015-09","categories":["petro"],"row_index":542,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Cold filter plugging point","parameters_en":[{"name":"[(-40)","range":"(0,0)] °C"}],"search_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME) Cold filter plugging point Optical method [(-40) PN-EN 116:2015-09","technique_en":"Optical method","test_object_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME)","search_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME） 冷滤点 光学法 PN-EN 116:2015-09","technique_zh":"光学法","test_object_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME）","methodology_zh":"冷滤点"},{"_id":"6a836fb9af14b9c0e7b1ed36","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Skłonność do blokowania filtra po wychładzaniu","parameters":[{"name":"Zakres","range":"(50,0 – 360) s"}],"technique":"Metoda filtracji po wychłodzeniu","techniques":["Metoda filtracji po wychłodzeniu"],"computed":[],"activity":"Skłonność do blokowania filtra po wychładzaniu\nZakres (50,0 – 360) s\nMetoda filtracji po wychłodzeniu","reference":"ASTM D 7501-22","norm_bases":["ASTM D 7501-22"],"lab_section":"Punkt Obsługi Laboratoryjnej w Olsztynie PP7/2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Skłonność do blokowania filtra po wychładzaniu\nZakres (50,0 – 360) s\nMetoda filtracji po wychłodzeniu ASTM D 7501-22 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Sklonnosc do blokowania filtra po wychladzaniu\nZakres (50,0 – 360) s\nMetoda filtracji po wychlodzeniu ASTM D 7501-22","categories":["petro"],"row_index":543,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Tendency to plug the filter after cooling","parameters_en":[{"name":"Range","range":"(50,0 – 360) s"}],"search_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME) Tendency to plug the filter after cooling Filtration after cooling method Range ASTM D 7501-22","technique_en":"Filtration after cooling method","test_object_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME)","parameters_zh":[{"name":"范围","range":"(50,0 – 360) s"}],"search_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME） 冷却后堵塞滤器的倾向 范围 ASTM D 7501-22","test_object_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME）","methodology_zh":"冷却后堵塞滤器的倾向"},{"_id":"6a836fb9af14b9c0e7b1ed37","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość zanieczyszczeń","parameters":[{"name":"Zakres","range":"(5,0 – 27,0) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość zanieczyszczeń\nZakres (5,0 – 27,0) mg/kg\nMetoda wagowa","reference":"PN-EN 12662-2:2024-11","norm_bases":["PN-EN 12662-2:2024-11"],"lab_section":"Punkt Obsługi Laboratoryjnej w Olsztynie PP7/2","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Zawartość zanieczyszczeń\nZakres (5,0 – 27,0) mg/kg\nMetoda wagowa PN-EN 12662-2:2024-11 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Zawartosc zanieczyszczen\nZakres (5,0 – 27,0) mg/kg\nMetoda wagowa PN-EN 12662-2:2024-11","categories":["petro"],"row_index":544,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Impurity content","parameters_en":[{"name":"Range","range":"(5,0 – 27,0) mg/kg"}],"search_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME) Impurity content Gravimetric method Range PN-EN 12662-2:2024-11","technique_en":"Gravimetric method","test_object_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME)","parameters_zh":[{"name":"范围","range":"(5,0 – 27,0) mg/kg"}],"search_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME） 杂质含量 重量法 范围 PN-EN 12662-2:2024-11","technique_zh":"重量法","methodology_zh":"杂质含量","test_object_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME）"},{"_id":"6a836fb9af14b9c0e7b1ed38","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME), bioetanol","methodology":"Pobieranie próbek punktowych ze zbiorników do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek punktowych ze zbiorników do badań chemicznych i fizycznych","reference":"PN-EN ISO 3170:2025-12 z wyłączeniem 8.3.1.3, 8.3.1.5, 8.3.1.6, 8.3.1.8, 8.3.2, 8.7-8.9, 9.8, 10.6, 10.7","norm_bases":["PN-EN ISO 3170:2025-12 z wyłączeniem 8.3.1.3, 8.3.1.5, 8.3.1.6, 8.3.1.8, 8.3.2, 8.7-8.9, 9.8, 10.6, 10.7"],"lab_section":"Punkt Obsługi Laboratoryjnej w Warszawie PP7/4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME), bioetanol Pobieranie próbek punktowych ze zbiorników do badań chemicznych i fizycznych PN-EN ISO 3170:2025-12 z wyłączeniem 8.3.1.3, 8.3.1.5, 8.3.1.6, 8.3.1.8, 8.3.2, 8.7-8.9, 9.8, 10.6, 10.7 Paliwa ciekle: benzyna bezolowiowa, olej napedowy biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME), bioetanol Pobieranie probek punktowych ze zbiornikow do badan chemicznych i fizycznych PN-EN ISO 3170:2025-12 z wylaczeniem 8.3.1.3, 8.3.1.5, 8.3.1.6, 8.3.1.8, 8.3.2, 8.7-8.9, 9.8, 10.6, 10.7","categories":["petro"],"row_index":545,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Spot sampling from tanks for chemical and physical testing","search_en":"Liquid fuels: unleaded petrol, diesel fuel liquid biofuels: fatty acid methyl esters (FAME), bioethanol Spot sampling from tanks for chemical and physical testing PN-EN ISO 3170:2025-12 z wyłączeniem 8.3.1.3, 8.3.1.5, 8.3.1.6, 8.3.1.8, 8.3.2, 8.7-8.9, 9.8, 10.6, 10.7","test_object_en":"Liquid fuels: unleaded petrol, diesel fuel liquid biofuels: fatty acid methyl esters (FAME), bioethanol"},{"_id":"6a836fb9af14b9c0e7b1ed39","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Prężność par nasyconych powietrzem","parameters":[{"name":"Zakres","range":"(40,0 – 106,0) kPa"}],"technique":"Metoda mini Reid","techniques":["Metoda mini Reid"],"computed":[],"activity":"Prężność par nasyconych powietrzem\nZakres (40,0 – 106,0) kPa\nMetoda mini Reid","reference":"PN-EN 13016-1:2024-11","norm_bases":["PN-EN 13016-1:2024-11"],"lab_section":"Punkt Obsługi Laboratoryjnej w Warszawie PP7/4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Prężność par nasyconych powietrzem\nZakres (40,0 – 106,0) kPa\nMetoda mini Reid PN-EN 13016-1:2024-11 Paliwa ciekle: benzyna bezolowiowa Preznosc par nasyconych powietrzem\nZakres (40,0 – 106,0) kPa\nMetoda mini Reid PN-EN 13016-1:2024-11","categories":["petro","environment"],"row_index":546,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air saturated vapour pressure","parameters_en":[{"name":"Range","range":"(40,0 – 106,0) kPa"}],"search_en":"Liquid fuels: unleaded petrol Air saturated vapour pressure Mini Reid method Range PN-EN 13016-1:2024-11","technique_en":"Mini Reid method","test_object_en":"Liquid fuels: unleaded petrol","parameters_zh":[{"name":"范围","range":"(40,0 – 106,0) kPa"}],"search_zh":"液体燃料：无铅汽油 空气饱和蒸气压 迷你雷德法 范围 PN-EN 13016-1:2024-11","test_object_zh":"液体燃料：无铅汽油","technique_zh":"迷你雷德法","methodology_zh":"空气饱和蒸气压"},{"_id":"6a836fb9af14b9c0e7b1ed3a","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Zawartość tlenowych związków organicznych","parameters":[{"name":"Zakres","range":"(0,17 – 15,0) %(v/v)"},{"name":"Całkowita zawartość organicznie związanego tlenu (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość tlenowych związków organicznych\nZakres:\nZakres (0,17 – 15,0) %(v/v)\nCałkowita zawartość organicznie związanego tlenu (z obliczeń)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13132:2005","norm_bases":["PN-EN 13132:2005"],"lab_section":"Punkt Obsługi Laboratoryjnej w Warszawie PP7/4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Zawartość tlenowych związków organicznych\nZakres:\nZakres (0,17 – 15,0) %(v/v)\nCałkowita zawartość organicznie związanego tlenu (z obliczeń)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13132:2005 Paliwa ciekle: benzyna bezolowiowa Zawartosc tlenowych zwiazkow organicznych\nZakres:\nZakres (0,17 – 15,0) %(v/v)\nCalkowita zawartosc organicznie zwiazanego tlenu (z obliczen)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13132:2005","categories":["petro"],"row_index":547,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of oxygenated organic compounds","parameters_en":[{"name":"Range","range":"(0,17 – 15,0) %(v/v)"},{"name":"Total organically bound oxygen content (calculated)"}],"search_en":"Liquid fuels: unleaded petrol Content of oxygenated organic compounds Gas chromatography with flame ionization detection (GC-FID) Range Total organically bound oxygen content (calculated) PN-EN 13132:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Liquid fuels: unleaded petrol","parameters_zh":[{"name":"范围","range":"(0,17 – 15,0) %(v/v)"},{"name":"有机结合氧总量（由计算得出）"}],"search_zh":"液体燃料：无铅汽油 含氧有机化合物含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 有机结合氧总量（由计算得出） PN-EN 13132:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"液体燃料：无铅汽油","methodology_zh":"含氧有机化合物含量"},{"_id":"6a836fb9af14b9c0e7b1ed3b","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Indeks lotności (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Indeks lotności (z obliczeń)","reference":"PN-EN 228+A1:2017-06 p. 5.5.2","norm_bases":["PN-EN 228+A1:2017-06 p. 5.5.2"],"lab_section":"Punkt Obsługi Laboratoryjnej w Warszawie PP7/4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Indeks lotności (z obliczeń) PN-EN 228+A1:2017-06 p. 5.5.2 Paliwa ciekle: benzyna bezolowiowa Indeks lotnosci (z obliczen) PN-EN 228+A1:2017-06 p. 5.5.2","categories":["petro"],"row_index":548,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Volatility index (calculated)","search_en":"Liquid fuels: unleaded petrol Volatility index (calculated) PN-EN 228+A1:2017-06 p. 5.5.2","test_object_en":"Liquid fuels: unleaded petrol","search_zh":"液体燃料：无铅汽油 挥发性指数（计算值） PN-EN 228+A1:2017-06 p. 5.5.2","test_object_zh":"液体燃料：无铅汽油","methodology_zh":"挥发性指数（计算值）"},{"_id":"6a836fb9af14b9c0e7b1ed3c","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Liczba oktanowa LOM","parameters":[{"name":"Zakres","range":"80,0 – 90,0"}],"technique":"Metoda silnikowa","techniques":["Metoda silnikowa"],"computed":[],"activity":"Liczba oktanowa LOM\nZakres 80,0 – 90,0\nMetoda silnikowa","reference":"PN-EN ISO 5163:2014-08","norm_bases":["PN-EN ISO 5163:2014-08"],"lab_section":"Punkt Obsługi Laboratoryjnej w Warszawie PP7/4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Liczba oktanowa LOM\nZakres 80,0 – 90,0\nMetoda silnikowa PN-EN ISO 5163:2014-08 Paliwa ciekle: benzyna bezolowiowa Liczba oktanowa LOM\nZakres 80,0 – 90,0\nMetoda silnikowa PN-EN ISO 5163:2014-08","categories":["petro"],"row_index":549,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Motor octane number MON","parameters_en":[{"name":"Range","range":"80,0 – 90,0"}],"search_en":"Liquid fuels: unleaded petrol Motor octane number MON Motor method Range PN-EN ISO 5163:2014-08","technique_en":"Motor method","test_object_en":"Liquid fuels: unleaded petrol","parameters_zh":[{"name":"范围","range":"80,0 – 90,0"}],"search_zh":"液体燃料：无铅汽油 马达法辛烷值 MON 发动机法 范围 PN-EN ISO 5163:2014-08","technique_zh":"发动机法","test_object_zh":"液体燃料：无铅汽油","methodology_zh":"马达法辛烷值 MON"},{"_id":"6a836fb9af14b9c0e7b1ed3d","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki","methodology":"Zawartość siarki","parameters":[{"name":"Zakres","range":"(3,0 – 60,0) mg/kg"}],"technique":"Metoda fluorescencji w nadfiolecie","techniques":["Metoda fluorescencji w nadfiolecie"],"computed":[],"activity":"Zawartość siarki\nZakres (3,0 – 60,0) mg/kg\nMetoda fluorescencji w nadfiolecie","reference":"PN-EN ISO 20846:2020-03","norm_bases":["PN-EN ISO 20846:2020-03"],"lab_section":"Punkt Obsługi Laboratoryjnej w Warszawie PP7/4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki Zawartość siarki\nZakres (3,0 – 60,0) mg/kg\nMetoda fluorescencji w nadfiolecie PN-EN ISO 20846:2020-03 Paliwa ciekle: benzyna bezolowiowa, olej napedowy, olej opalowy lekki Zawartosc siarki\nZakres (3,0 – 60,0) mg/kg\nMetoda fluorescencji w nadfiolecie PN-EN ISO 20846:2020-03","categories":["petro"],"row_index":550,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfur content","parameters_en":[{"name":"Range","range":"(3,0 – 60,0) mg/kg"}],"search_en":"Liquid fuels: unleaded petrol, diesel fuel, light fuel oil Sulfur content Ultraviolet fluorescence method Range PN-EN ISO 20846:2020-03","technique_en":"Ultraviolet fluorescence method","test_object_en":"Liquid fuels: unleaded petrol, diesel fuel, light fuel oil","parameters_zh":[{"name":"范围","range":"(3,0 – 60,0) mg/kg"}],"search_zh":"液体燃料：无铅汽油、柴油、轻质燃料油 硫含量 紫外荧光法 范围 PN-EN ISO 20846:2020-03","methodology_zh":"硫含量","technique_zh":"紫外荧光法","test_object_zh":"液体燃料：无铅汽油、柴油、轻质燃料油"},{"_id":"6a836fb9af14b9c0e7b1ed3e","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki","methodology":"Gęstość w temperaturze 15°C","parameters":[{"name":"Zakres","range":"(700,0 – 900,0) kg/m3"}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"computed":[],"activity":"Gęstość w temperaturze 15°C\nZakres (700,0 – 900,0) kg/m3\nMetoda oscylacyjna","reference":"PN-EN ISO 12185:2024-08","norm_bases":["PN-EN ISO 12185:2024-08"],"lab_section":"Punkt Obsługi Laboratoryjnej w Warszawie PP7/4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki Gęstość w temperaturze 15°C\nZakres (700,0 – 900,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08 Paliwa ciekle: benzyna bezolowiowa, olej napedowy, olej opalowy lekki Gestosc w temperaturze 15°C\nZakres (700,0 – 900,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08","categories":["petro"],"row_index":551,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Density at 15°C","parameters_en":[{"name":"Range","range":"(700,0 – 900,0) kg/m3"}],"search_en":"Liquid fuels: unleaded petrol, diesel fuel, light fuel oil Density at 15°C Oscillation method Range PN-EN ISO 12185:2024-08","technique_en":"Oscillation method","test_object_en":"Liquid fuels: unleaded petrol, diesel fuel, light fuel oil","parameters_zh":[{"name":"范围","range":"(700,0 – 900,0) kg/m3"}],"search_zh":"液体燃料：无铅汽油、柴油、轻质燃料油 15°C 时的密度 振荡法 范围 PN-EN ISO 12185:2024-08","technique_zh":"振荡法","methodology_zh":"15°C 时的密度","test_object_zh":"液体燃料：无铅汽油、柴油、轻质燃料油"},{"_id":"6a836fb9af14b9c0e7b1ed3f","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki","methodology":"Skład frakcyjny","parameters":[{"name":"Zakres","range":"(30,0 – 370,0) 0C"}],"technique":"Metoda destylacyjna","techniques":["Metoda destylacyjna"],"computed":[],"activity":"Skład frakcyjny\nZakres (30,0 – 370,0) 0C\nMetoda destylacyjna","reference":"PN-EN ISO 3405:2019-05","norm_bases":["PN-EN ISO 3405:2019-05"],"lab_section":"Punkt Obsługi Laboratoryjnej w Warszawie PP7/4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa, olej napędowy, olej opałowy lekki Skład frakcyjny\nZakres (30,0 – 370,0) 0C\nMetoda destylacyjna PN-EN ISO 3405:2019-05 Paliwa ciekle: benzyna bezolowiowa, olej napedowy, olej opalowy lekki Sklad frakcyjny\nZakres (30,0 – 370,0) 0C\nMetoda destylacyjna PN-EN ISO 3405:2019-05","categories":["petro"],"row_index":552,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fractional composition","parameters_en":[{"name":"Range","range":"(30,0 – 370,0) 0C"}],"search_en":"Liquid fuels: unleaded petrol, diesel fuel, light fuel oil Fractional composition Distillation method Range PN-EN ISO 3405:2019-05","technique_en":"Distillation method","test_object_en":"Liquid fuels: unleaded petrol, diesel fuel, light fuel oil","parameters_zh":[{"name":"范围","range":"(30,0 – 370,0) 0C"}],"search_zh":"液体燃料：无铅汽油、柴油、轻质燃料油 馏程组成 蒸馏法 范围 PN-EN ISO 3405:2019-05","technique_zh":"蒸馏法","methodology_zh":"馏程组成","test_object_zh":"液体燃料：无铅汽油、柴油、轻质燃料油"},{"_id":"6a836fb9af14b9c0e7b1ed40","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Gęstość w temperaturze 15°C","parameters":[{"name":"Zakres","range":"(800,0 – 900,0) kg/m3"}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"computed":[],"activity":"Gęstość w temperaturze 15°C\nZakres (800,0 – 900,0) kg/m3\nMetoda oscylacyjna","reference":"PN-EN ISO 12185:2024-08","norm_bases":["PN-EN ISO 12185:2024-08"],"lab_section":"Punkt Obsługi Laboratoryjnej w Warszawie PP7/4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Gęstość w temperaturze 15°C\nZakres (800,0 – 900,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Gestosc w temperaturze 15°C\nZakres (800,0 – 900,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08","categories":["petro"],"row_index":553,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Density at 15°C","parameters_en":[{"name":"Range","range":"(800,0 – 900,0) kg/m3"}],"search_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME) Density at 15°C Oscillation method Range PN-EN ISO 12185:2024-08","technique_en":"Oscillation method","test_object_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME)","parameters_zh":[{"name":"范围","range":"(800,0 – 900,0) kg/m3"}],"search_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME） 15°C 时的密度 振荡法 范围 PN-EN ISO 12185:2024-08","technique_zh":"振荡法","test_object_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME）","methodology_zh":"15°C 时的密度"},{"_id":"6a836fb9af14b9c0e7b1ed41","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość wody","parameters":[{"name":"Zakres","range":"(0,003 – 0,100) %(m/m)"}],"technique":"Metoda miareczkowania kulometrycznego","techniques":["Metoda miareczkowania kulometrycznego"],"computed":[],"activity":"Zawartość wody\nZakres (0,003 – 0,100) %(m/m)\nMetoda miareczkowania kulometrycznego","reference":"PN-EN ISO 12937:2005+Ap1:2021-11","norm_bases":["PN-EN ISO 12937:2005+Ap1:2021-11"],"lab_section":"Punkt Obsługi Laboratoryjnej w Warszawie PP7/4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Zawartość wody\nZakres (0,003 – 0,100) %(m/m)\nMetoda miareczkowania kulometrycznego PN-EN ISO 12937:2005+Ap1:2021-11 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Zawartosc wody\nZakres (0,003 – 0,100) %(m/m)\nMetoda miareczkowania kulometrycznego PN-EN ISO 12937:2005+Ap1:2021-11","categories":["petro","water"],"row_index":554,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water content","parameters_en":[{"name":"Range","range":"(0,003 – 0,100) %(m/m)"}],"search_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME) Water content Coulometric titration method Range PN-EN ISO 12937:2005+Ap1:2021-11","technique_en":"Coulometric titration method","test_object_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME)","methodology_zh":"水分含量","parameters_zh":[{"name":"范围","range":"(0,003 – 0,100) %(m/m)"}],"search_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME） 水分含量 库仑滴定法 范围 PN-EN ISO 12937:2005+Ap1:2021-11","technique_zh":"库仑滴定法","test_object_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME）"},{"_id":"6a836fb9af14b9c0e7b1ed42","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Skłonność do blokowania filtra po wychładzaniu","parameters":[{"name":"Zakres","range":"(50 – 650) s"}],"technique":"Metoda filtracji po wychładzaniu","techniques":["Metoda filtracji po wychładzaniu"],"computed":[],"activity":"Skłonność do blokowania filtra po wychładzaniu\nZakres (50 – 650) s\nMetoda filtracji po wychładzaniu","reference":"ASTM D 7501-22","norm_bases":["ASTM D 7501-22"],"lab_section":"Punkt Obsługi Laboratoryjnej w Warszawie PP7/4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Skłonność do blokowania filtra po wychładzaniu\nZakres (50 – 650) s\nMetoda filtracji po wychładzaniu ASTM D 7501-22 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Sklonnosc do blokowania filtra po wychladzaniu\nZakres (50 – 650) s\nMetoda filtracji po wychladzaniu ASTM D 7501-22","categories":["petro"],"row_index":555,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Tendency to plug the filter after cooling","parameters_en":[{"name":"Range","range":"(50 – 650) s"}],"search_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME) Tendency to plug the filter after cooling Filtration method after cooling Range ASTM D 7501-22","technique_en":"Filtration method after cooling","test_object_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME)","parameters_zh":[{"name":"范围","range":"(50 – 650) s"}],"search_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME） 冷却后堵塞滤器的倾向 范围 ASTM D 7501-22","test_object_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME）","methodology_zh":"冷却后堵塞滤器的倾向"},{"_id":"6a836fb9af14b9c0e7b1ed43","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Stabilność oksydacyjna","parameters":[{"name":"Zakres","range":"(1,0 – 16,0) h"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Stabilność oksydacyjna\nZakres (1,0 – 16,0) h\nMetoda konduktometryczna","reference":"PN-EN 15751:2014-05","norm_bases":["PN-EN 15751:2014-05"],"lab_section":"Punkt Obsługi Laboratoryjnej w Warszawie PP7/4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Stabilność oksydacyjna\nZakres (1,0 – 16,0) h\nMetoda konduktometryczna PN-EN 15751:2014-05 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Stabilnosc oksydacyjna\nZakres (1,0 – 16,0) h\nMetoda konduktometryczna PN-EN 15751:2014-05","categories":["petro"],"row_index":556,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Oxidation stability","parameters_en":[{"name":"Range","range":"(1,0 – 16,0) h"}],"search_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME) Oxidation stability Conductometric method Range PN-EN 15751:2014-05","technique_en":"Conductometric method","test_object_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME)","parameters_zh":[{"name":"范围","range":"(1,0 – 16,0) h"}],"search_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME） 氧化安定性 电导法 范围 PN-EN 15751:2014-05","technique_zh":"电导法","methodology_zh":"氧化安定性","test_object_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME）"},{"_id":"6a836fb9af14b9c0e7b1ed44","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki","methodology":"Lepkość kinematyczna w temp. 40 °C","parameters":[{"name":"Zakres","range":"(2,000 – 6,000) mm2/s"}],"technique":"Metoda kapilarna","techniques":["Metoda kapilarna"],"computed":[],"activity":"Lepkość kinematyczna w temp. 40 °C\nZakres (2,000 – 6,000) mm2/s\nMetoda kapilarna","reference":"PN-EN ISO 3104:2024-01 Procedura A","norm_bases":["PN-EN ISO 3104:2024-01 Procedura A"],"lab_section":"Punkt Obsługi Laboratoryjnej w Warszawie PP7/4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki Lepkość kinematyczna w temp. 40 °C\nZakres (2,000 – 6,000) mm2/s\nMetoda kapilarna PN-EN ISO 3104:2024-01 Procedura A Paliwa ciekle: olej napedowy, olej opalowy lekki Lepkosc kinematyczna w temp. 40 °C\nZakres (2,000 – 6,000) mm2/s\nMetoda kapilarna PN-EN ISO 3104:2024-01 Procedura A","categories":["petro"],"row_index":557,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kinematic viscosity at 40 °C","parameters_en":[{"name":"Range","range":"(2,000 – 6,000) mm2/s"}],"search_en":"Liquid fuels: diesel fuel, light fuel oil Kinematic viscosity at 40 °C Capillary method Range PN-EN ISO 3104:2024-01 Procedura A","technique_en":"Capillary method","test_object_en":"Liquid fuels: diesel fuel, light fuel oil","parameters_zh":[{"name":"范围","range":"(2,000 – 6,000) mm2/s"}],"search_zh":"液体燃料：柴油、轻质燃料油 毛细管法 范围 PN-EN ISO 3104:2024-01 Procedura A","technique_zh":"毛细管法","test_object_zh":"液体燃料：柴油、轻质燃料油"},{"_id":"6a836fb9af14b9c0e7b1ed45","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki","methodology":"Temperatura zapłonu","parameters":[{"name":"Zakres","range":"(40,0 – 100,0) °C"}],"technique":"Metoda zamkniętego tygla Pensky’ego-Martensa","techniques":["Metoda zamkniętego tygla Pensky’ego-Martensa"],"computed":[],"activity":"Temperatura zapłonu\nZakres (40,0 – 100,0) °C\nMetoda zamkniętego tygla Pensky’ego-Martensa","reference":"PN-EN ISO 2719:2016-08+A1:2021-06","norm_bases":["PN-EN ISO 2719:2016-08+A1:2021-06"],"lab_section":"Punkt Obsługi Laboratoryjnej w Warszawie PP7/4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki Temperatura zapłonu\nZakres (40,0 – 100,0) °C\nMetoda zamkniętego tygla Pensky’ego-Martensa PN-EN ISO 2719:2016-08+A1:2021-06 Paliwa ciekle: olej napedowy, olej opalowy lekki Temperatura zaplonu\nZakres (40,0 – 100,0) °C\nMetoda zamknietego tygla Pensky’ego-Martensa PN-EN ISO 2719:2016-08+A1:2021-06","categories":["petro"],"row_index":558,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Flash point","parameters_en":[{"name":"Range","range":"(40,0 – 100,0) °C"}],"search_en":"Liquid fuels: diesel fuel, light fuel oil Flash point Pensky-Martens closed cup method Range PN-EN ISO 2719:2016-08+A1:2021-06","technique_en":"Pensky-Martens closed cup method","test_object_en":"Liquid fuels: diesel fuel, light fuel oil","parameters_zh":[{"name":"范围","range":"(40,0 – 100,0) °C"}],"search_zh":"液体燃料：柴油、轻质燃料油 闪点 宾斯基-马丁闭口杯法 范围 PN-EN ISO 2719:2016-08+A1:2021-06","methodology_zh":"闪点","test_object_zh":"液体燃料：柴油、轻质燃料油","technique_zh":"宾斯基-马丁闭口杯法"},{"_id":"6a836fb9af14b9c0e7b1ed46","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki","methodology":"Zawartość wody","parameters":[{"name":"Zakres","range":"(0,003 – 0,100) %(m/m)"}],"technique":"Metoda miareczkowania kulometrycznego","techniques":["Metoda miareczkowania kulometrycznego"],"computed":[],"activity":"Zawartość wody\nZakres (0,003 – 0,100) %(m/m)\nMetoda miareczkowania kulometrycznego","reference":"PN-EN ISO 12937:2005+Ap1:2021-11","norm_bases":["PN-EN ISO 12937:2005+Ap1:2021-11"],"lab_section":"Punkt Obsługi Laboratoryjnej w Warszawie PP7/4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki Zawartość wody\nZakres (0,003 – 0,100) %(m/m)\nMetoda miareczkowania kulometrycznego PN-EN ISO 12937:2005+Ap1:2021-11 Paliwa ciekle: olej napedowy, olej opalowy lekki Zawartosc wody\nZakres (0,003 – 0,100) %(m/m)\nMetoda miareczkowania kulometrycznego PN-EN ISO 12937:2005+Ap1:2021-11","categories":["petro","water"],"row_index":559,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water content","parameters_en":[{"name":"Range","range":"(0,003 – 0,100) %(m/m)"}],"search_en":"Liquid fuels: diesel fuel, light fuel oil Water content Coulometric titration method Range PN-EN ISO 12937:2005+Ap1:2021-11","technique_en":"Coulometric titration method","test_object_en":"Liquid fuels: diesel fuel, light fuel oil","methodology_zh":"水分含量","parameters_zh":[{"name":"范围","range":"(0,003 – 0,100) %(m/m)"}],"search_zh":"液体燃料：柴油、轻质燃料油 水分含量 库仑滴定法 范围 PN-EN ISO 12937:2005+Ap1:2021-11","technique_zh":"库仑滴定法","test_object_zh":"液体燃料：柴油、轻质燃料油"},{"_id":"6a836fb9af14b9c0e7b1ed47","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki","methodology":"Zawartość zanieczyszczeń","parameters":[{"name":"Zakres","range":"(12,0 – 26,0) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość zanieczyszczeń\nZakres (12,0 – 26,0) mg/kg\nMetoda wagowa","reference":"PN-EN 12662-1:2024-11","norm_bases":["PN-EN 12662-1:2024-11"],"lab_section":"Punkt Obsługi Laboratoryjnej w Warszawie PP7/4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki Zawartość zanieczyszczeń\nZakres (12,0 – 26,0) mg/kg\nMetoda wagowa PN-EN 12662-1:2024-11 Paliwa ciekle: olej napedowy, olej opalowy lekki Zawartosc zanieczyszczen\nZakres (12,0 – 26,0) mg/kg\nMetoda wagowa PN-EN 12662-1:2024-11","categories":["petro"],"row_index":560,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Impurity content","parameters_en":[{"name":"Range","range":"(12,0 – 26,0) mg/kg"}],"search_en":"Liquid fuels: diesel fuel, light fuel oil Impurity content Gravimetric method Range PN-EN 12662-1:2024-11","technique_en":"Gravimetric method","test_object_en":"Liquid fuels: diesel fuel, light fuel oil","parameters_zh":[{"name":"范围","range":"(12,0 – 26,0) mg/kg"}],"search_zh":"液体燃料：柴油、轻质燃料油 杂质含量 重量法 范围 PN-EN 12662-1:2024-11","technique_zh":"重量法","methodology_zh":"杂质含量","test_object_zh":"液体燃料：柴油、轻质燃料油"},{"_id":"6a836fb9af14b9c0e7b1ed48","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, biopaliwa ciekłe: olej napędowy z FAME","methodology":"Zawartość estrów metylowych kwasów tłuszczowych (FAME)","parameters":[{"name":"Zakres","range":"(3,0 – 20,0) %(v/v)"}],"technique":"Metoda spektrometrii w zakresie podczerwieni IR","techniques":["Metoda spektrometrii w zakresie podczerwieni IR"],"computed":[],"activity":"Zawartość estrów metylowych kwasów tłuszczowych (FAME)\nZakres (3,0 – 20,0) %(v/v)\nMetoda spektrometrii w zakresie podczerwieni IR","reference":"PN-EN 14078:2014-06","norm_bases":["PN-EN 14078:2014-06"],"lab_section":"Punkt Obsługi Laboratoryjnej w Warszawie PP7/4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, biopaliwa ciekłe: olej napędowy z FAME Zawartość estrów metylowych kwasów tłuszczowych (FAME)\nZakres (3,0 – 20,0) %(v/v)\nMetoda spektrometrii w zakresie podczerwieni IR PN-EN 14078:2014-06 Paliwa ciekle: olej napedowy, olej opalowy lekki, biopaliwa ciekle: olej napedowy z FAME Zawartosc estrow metylowych kwasow tluszczowych (FAME)\nZakres (3,0 – 20,0) %(v/v)\nMetoda spektrometrii w zakresie podczerwieni IR PN-EN 14078:2014-06","categories":["petro"],"row_index":561,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fatty acid methyl esters (FAME) content","parameters_en":[{"name":"Range","range":"(3,0 – 20,0) %(v/v)"}],"search_en":"Liquid fuels: diesel fuel, light fuel oil, liquid biofuels: diesel fuel with FAME Fatty acid methyl esters (FAME) content Spectrometry method in the infrared range IR Range PN-EN 14078:2014-06","technique_en":"Spectrometry method in the infrared range IR","test_object_en":"Liquid fuels: diesel fuel, light fuel oil, liquid biofuels: diesel fuel with FAME","parameters_zh":[{"name":"范围","range":"(3,0 – 20,0) %(v/v)"}],"search_zh":"脂肪酸甲酯（FAME）含量 红外光谱法 IR 范围 PN-EN 14078:2014-06","technique_zh":"红外光谱法 IR","methodology_zh":"脂肪酸甲酯（FAME）含量"},{"_id":"6a836fb9af14b9c0e7b1ed49","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość zanieczyszczeń","parameters":[{"name":"Zakres","range":"(5,0 – 27,0) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość zanieczyszczeń\nZakres (5,0 – 27,0) mg/kg\nMetoda wagowa","reference":"PN-EN 12662-2:2024-11","norm_bases":["PN-EN 12662-2:2024-11"],"lab_section":"Punkt Obsługi Laboratoryjnej w Warszawie PP7/4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Zawartość zanieczyszczeń\nZakres (5,0 – 27,0) mg/kg\nMetoda wagowa PN-EN 12662-2:2024-11 Paliwa ciekle: biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Zawartosc zanieczyszczen\nZakres (5,0 – 27,0) mg/kg\nMetoda wagowa PN-EN 12662-2:2024-11","categories":["petro"],"row_index":562,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Impurity content","parameters_en":[{"name":"Range","range":"(5,0 – 27,0) mg/kg"}],"search_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME) Impurity content Gravimetric method Range PN-EN 12662-2:2024-11","technique_en":"Gravimetric method","test_object_en":"Liquid fuels: liquid biofuels: fatty acid methyl esters (FAME)","parameters_zh":[{"name":"范围","range":"(5,0 – 27,0) mg/kg"}],"search_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME） 杂质含量 重量法 范围 PN-EN 12662-2:2024-11","technique_zh":"重量法","methodology_zh":"杂质含量","test_object_zh":"液体燃料：液体生物燃料：脂肪酸甲酯（FAME）"},{"_id":"6a836fb9af14b9c0e7b1ed4a","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: bioetanol","methodology":"Moc","parameters":[{"name":"Zakres","range":"(90,0 – 100,0) %(v/v)"}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"computed":[],"activity":"Moc\nZakres (90,0 – 100,0) %(v/v)\nMetoda oscylacyjna","reference":"PN-A-79528-3:2007 p. 5.2","norm_bases":["PN-A-79528-3:2007 p. 5.2"],"lab_section":"Punkt Obsługi Laboratoryjnej w Warszawie PP7/4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: bioetanol Moc\nZakres (90,0 – 100,0) %(v/v)\nMetoda oscylacyjna PN-A-79528-3:2007 p. 5.2 Paliwa ciekle: biopaliwa ciekle: bioetanol Moc\nZakres (90,0 – 100,0) %(v/v)\nMetoda oscylacyjna PN-A-79528-3:2007 p. 5.2","categories":["petro"],"row_index":563,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Power","parameters_en":[{"name":"Range","range":"(90,0 – 100,0) %(v/v)"}],"search_en":"Liquid fuels: liquid biofuels: bioethanol Power Oscillation method Range PN-A-79528-3:2007 p. 5.2","technique_en":"Oscillation method","test_object_en":"Liquid fuels: liquid biofuels: bioethanol","parameters_zh":[{"name":"范围","range":"(90,0 – 100,0) %(v/v)"}],"search_zh":"液体燃料：液体生物燃料：生物乙醇 功率 振荡法 范围 PN-A-79528-3:2007 p. 5.2","technique_zh":"振荡法","methodology_zh":"功率","test_object_zh":"液体燃料：液体生物燃料：生物乙醇"},{"_id":"6a836fb9af14b9c0e7b1ed4b","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: biopaliwa ciekłe: bioetanol","methodology":"Gęstość w temperaturze 20°C","parameters":[{"name":"Zakres","range":"(789,0 – 830,0) kg/m3"}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"computed":[],"activity":"Gęstość w temperaturze 20°C\nZakres (789,0 – 830,0) kg/m3\nMetoda oscylacyjna","reference":"PN-EN ISO 12185:2024-08","norm_bases":["PN-EN ISO 12185:2024-08"],"lab_section":"Punkt Obsługi Laboratoryjnej w Warszawie PP7/4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: biopaliwa ciekłe: bioetanol Gęstość w temperaturze 20°C\nZakres (789,0 – 830,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08 Paliwa ciekle: biopaliwa ciekle: bioetanol Gestosc w temperaturze 20°C\nZakres (789,0 – 830,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08","categories":["petro"],"row_index":564,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Density at 20°C","parameters_en":[{"name":"Range","range":"(789,0 – 830,0) kg/m3"}],"search_en":"Liquid fuels: liquid biofuels: bioethanol Density at 20°C Oscillation method Range PN-EN ISO 12185:2024-08","technique_en":"Oscillation method","test_object_en":"Liquid fuels: liquid biofuels: bioethanol","parameters_zh":[{"name":"范围","range":"(789,0 – 830,0) kg/m3"}],"search_zh":"液体燃料：液体生物燃料：生物乙醇 振荡法 范围 PN-EN ISO 12185:2024-08","technique_zh":"振荡法","test_object_zh":"液体燃料：液体生物燃料：生物乙醇"},{"_id":"6a836fb9af14b9c0e7b1ed4c","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy","methodology":"Stabilność oksydacyjna","parameters":[{"name":"Zakres","range":"(5,0 – 48,0) h"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Stabilność oksydacyjna\nZakres (5,0 – 48,0) h\nMetoda konduktometryczna","reference":"PN-EN 15751:2014-05","norm_bases":["PN-EN 15751:2014-05"],"lab_section":"Punkt Obsługi Laboratoryjnej w Warszawie PP7/4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy Stabilność oksydacyjna\nZakres (5,0 – 48,0) h\nMetoda konduktometryczna PN-EN 15751:2014-05 Paliwa ciekle: olej napedowy Stabilnosc oksydacyjna\nZakres (5,0 – 48,0) h\nMetoda konduktometryczna PN-EN 15751:2014-05","categories":["petro"],"row_index":565,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Oxidation stability","parameters_en":[{"name":"Range","range":"(5,0 – 48,0) h"}],"search_en":"Liquid fuels: diesel fuel Oxidation stability Conductometric method Range PN-EN 15751:2014-05","technique_en":"Conductometric method","test_object_en":"Liquid fuels: diesel fuel","parameters_zh":[{"name":"范围","range":"(5,0 – 48,0) h"}],"search_zh":"液体燃料：柴油 氧化安定性 电导法 范围 PN-EN 15751:2014-05","technique_zh":"电导法","test_object_zh":"液体燃料：柴油","methodology_zh":"氧化安定性"},{"_id":"6a836fb9af14b9c0e7b1ed4d","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy","methodology":"Indeks cetanowy (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Indeks cetanowy (z obliczeń)","reference":"PN-EN ISO 4264:2018-08","norm_bases":["PN-EN ISO 4264:2018-08"],"lab_section":"Punkt Obsługi Laboratoryjnej w Warszawie PP7/4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy Indeks cetanowy (z obliczeń) PN-EN ISO 4264:2018-08 Paliwa ciekle: olej napedowy Indeks cetanowy (z obliczen) PN-EN ISO 4264:2018-08","categories":["petro"],"row_index":566,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Cetane index (calculated)","search_en":"Liquid fuels: diesel fuel Cetane index (calculated) PN-EN ISO 4264:2018-08","test_object_en":"Liquid fuels: diesel fuel","search_zh":"液体燃料：柴油 十六烷指数（计算值） PN-EN ISO 4264:2018-08","test_object_zh":"液体燃料：柴油","methodology_zh":"十六烷指数（计算值）"},{"_id":"6a836fb9af14b9c0e7b1ed4e","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy","methodology":"Temperatura zablokowania zimnego filtra","parameters":[{"name":"[0°C","range":"(- 40)] °C"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Temperatura zablokowania zimnego filtra\n[0°C (- 40)] °C\nMetoda optyczna","reference":"PN-EN 116:2015-09","norm_bases":["PN-EN 116:2015-09"],"lab_section":"Punkt Obsługi Laboratoryjnej w Warszawie PP7/4","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy Temperatura zablokowania zimnego filtra\n[0°C (- 40)] °C\nMetoda optyczna PN-EN 116:2015-09 Paliwa ciekle: olej napedowy Temperatura zablokowania zimnego filtra\n[0°C (- 40)] °C\nMetoda optyczna PN-EN 116:2015-09","categories":["petro"],"row_index":567,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Cold filter plugging point","parameters_en":[{"name":"[0°C","range":"(- 40)] °C"}],"search_en":"Liquid fuels: diesel fuel Cold filter plugging point Optical method [0°C PN-EN 116:2015-09","technique_en":"Optical method","test_object_en":"Liquid fuels: diesel fuel","search_zh":"液体燃料：柴油 冷滤点 光学法 PN-EN 116:2015-09","technique_zh":"光学法","test_object_zh":"液体燃料：柴油","methodology_zh":"冷滤点"},{"_id":"6a836fb9af14b9c0e7b1ed4f","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(2 – 100) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Barwa\nZakres (2 – 100) mg/l Pt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012+Ap1:2015-06 metoda C","norm_bases":["PN-EN ISO 7887:2012+Ap1:2015-06 metoda C"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Barwa\nZakres (2 – 100) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012+Ap1:2015-06 metoda C Woda Barwa\nZakres (2 – 100) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012+Ap1:2015-06 metoda C","categories":["water"],"row_index":568,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"(2 – 100) mg/l Pt"}],"search_en":"Water Colour Spectrophotometric method Range PN-EN ISO 7887:2012+Ap1:2015-06 metoda C","technique_en":"Spectrophotometric method","test_object_en":"Water","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(2 – 100) mg/l Pt"}],"search_zh":"水 色度 分光光度法 范围 PN-EN ISO 7887:2012+Ap1:2015-06 metoda C","technique_zh":"分光光度法","test_object_zh":"水"},{"_id":"6a836fb9af14b9c0e7b1ed50","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie benzenu","parameters":[{"name":"Zakres","range":"(0,25 – 10) μg/l"}],"technique":"Metoda chromatografii gazowej ze statyczną analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID)","techniques":["Metoda chromatografii gazowej ze statyczną analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID)"],"computed":[],"activity":"Stężenie benzenu\nZakres (0,25 – 10) μg/l\nMetoda chromatografii gazowej ze statyczną analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID)","reference":"PN-ISO 11423-1:2002","norm_bases":["PN-ISO 11423-1:2002"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie benzenu\nZakres (0,25 – 10) μg/l\nMetoda chromatografii gazowej ze statyczną analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID) PN-ISO 11423-1:2002 Woda Stezenie benzenu\nZakres (0,25 – 10) μg/l\nMetoda chromatografii gazowej ze statyczna analiza fazy nadpowierzchniowej i detekcja plomieniowo-jonizacyjna (HS-GC-FID) PN-ISO 11423-1:2002","categories":["water"],"row_index":569,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Benzene concentration","parameters_en":[{"name":"Range","range":"(0,25 – 10) μg/l"}],"search_en":"Water Benzene concentration Gas chromatography with static headspace analysis and flame ionization detection (HS-GC-FID) Range PN-ISO 11423-1:2002","technique_en":"Gas chromatography with static headspace analysis and flame ionization detection (HS-GC-FID)","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,25 – 10) μg/l"}],"search_zh":"水 苯浓度 范围 PN-ISO 11423-1:2002","test_object_zh":"水","methodology_zh":"苯浓度"},{"_id":"6a836fb9af14b9c0e7b1ed51","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,50 – 50) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,50 – 50) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Mętność\nZakres (0,50 – 50) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda Metnosc\nZakres (0,50 – 50) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":570,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,50 – 50) NTU"}],"search_en":"Water Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09","technique_en":"Nephelometric method","test_object_en":"Water","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,50 – 50) NTU"}],"search_zh":"水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"水"},{"_id":"6a836fb9af14b9c0e7b1ed52","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, scieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":571,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"search_en":"Water, wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water, wastewater","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"水、废水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、废水"},{"_id":"6a836fb9af14b9c0e7b1ed53","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0 – 5000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 5000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Zawiesiny ogólne\nZakres (2,0 – 5000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, scieki Zawiesiny ogolne\nZakres (2,0 – 5000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":572,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2,0 – 5000) mg/l"}],"search_en":"Water, wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 5000) mg/l"}],"search_zh":"水、废水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"水、废水"},{"_id":"6a836fb9af14b9c0e7b1ed54","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Sucha pozostałość","parameters":[{"name":"Zakres","range":"(10 – 5000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha pozostałość\nZakres (10 – 5000) mg/l\nMetoda wagowa","reference":"PN-78/C-04541 pkt 4.1","norm_bases":["PN-78/C-04541 pkt 4.1"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Sucha pozostałość\nZakres (10 – 5000) mg/l\nMetoda wagowa PN-78/C-04541 pkt 4.1 Woda, scieki Sucha pozostalosc\nZakres (10 – 5000) mg/l\nMetoda wagowa PN-78/C-04541 pkt 4.1","categories":["water"],"row_index":573,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry residue","parameters_en":[{"name":"Range","range":"(10 – 5000) mg/l"}],"search_en":"Water, wastewater Dry residue Gravimetric method Range PN-78/C-04541 pkt 4.1","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(10 – 5000) mg/l"}],"search_zh":"水、废水 干残渣 重量法 范围 PN-78/C-04541 pkt 4.1","technique_zh":"重量法","test_object_zh":"水、废水","methodology_zh":"干残渣"},{"_id":"6a836fb9af14b9c0e7b1ed55","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(10 – 1 300) mS/m"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (10 – 1 300) mS/m\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Przewodność elektryczna właściwa\nZakres (10 – 1 300) mS/m\nMetoda konduktometryczna PN-EN 27888:1999 Woda, scieki Przewodnosc elektryczna wlasciwa\nZakres (10 – 1 300) mS/m\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":574,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(10 – 1 300) mS/m"}],"search_en":"Water, wastewater Electrical conductivity Conductometric method Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water, wastewater","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(10 – 1 300) mS/m"}],"search_zh":"水、废水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、废水"},{"_id":"6a836fb9af14b9c0e7b1ed56","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotynów","parameters":[{"name":"Zakres","range":"(0,050 – 33) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotynów\nZakres (0,050 – 33) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotynów\nZakres (0,050 – 33) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, scieki Stezenie azotynow\nZakres (0,050 – 33) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":575,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite concentration","parameters_en":[{"name":"Range","range":"(0,050 – 33) mg/l"}],"search_en":"Water, wastewater Nitrite concentration Spectrophotometric method Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,050 – 33) mg/l"}],"search_zh":"水、废水 亚硝酸盐浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a836fb9af14b9c0e7b1ed57","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu azotynowego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu azotynowego (z obliczeń)","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu azotynowego (z obliczeń) PN-EN 26777:1999 Woda, scieki Stezenie azotu azotynowego (z obliczen) PN-EN 26777:1999","categories":["water"],"row_index":576,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite nitrogen concentration (calculated)","search_en":"Water, wastewater Nitrite nitrogen concentration (calculated) PN-EN 26777:1999","test_object_en":"Water, wastewater","search_zh":"水、废水 亚硝酸盐氮浓度（由计算得出） PN-EN 26777:1999","test_object_zh":"水、废水","methodology_zh":"亚硝酸盐氮浓度（由计算得出）"},{"_id":"6a836fb9af14b9c0e7b1ed58","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotynów","parameters":[{"name":"Zakres","range":"(0,050 – 20) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie azotynów\nZakres (0,050 – 20) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotynów\nZakres (0,050 – 20) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Woda, scieki Stezenie azotynow\nZakres (0,050 – 20) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":577,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite concentration","parameters_en":[{"name":"Range","range":"(0,050 – 20) mg/l"}],"search_en":"Water, wastewater Nitrite concentration Ion chromatography with conductometric detection (IC-CD) Range PN-EN ISO 10304-1:2009+AC:2012","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water, wastewater","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,050 – 20) mg/l"}],"search_zh":"水、废水 亚硝酸盐浓度 离子色谱-电导检测法（IC-CD） 范围 PN-EN ISO 10304-1:2009+AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水、废水"},{"_id":"6a836fb9af14b9c0e7b1ed59","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu azotynowego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu azotynowego (z obliczeń)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu azotynowego (z obliczeń) PN-EN ISO 10304-1:2009+AC:2012 Woda, scieki Stezenie azotu azotynowego (z obliczen) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":578,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite nitrogen concentration (calculated)","search_en":"Water, wastewater Nitrite nitrogen concentration (calculated) PN-EN ISO 10304-1:2009+AC:2012","test_object_en":"Water, wastewater","search_zh":"水、废水 亚硝酸盐氮浓度（由计算得出） PN-EN ISO 10304-1:2009+AC:2012","test_object_zh":"水、废水","methodology_zh":"亚硝酸盐氮浓度（由计算得出）"},{"_id":"6a836fb9af14b9c0e7b1ed5a","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotanów","parameters":[{"name":"Zakres","range":"(0,050 – 2000) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie azotanów\nZakres (0,050 – 2000) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotanów\nZakres (0,050 – 2000) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Woda, scieki Stezenie azotanow\nZakres (0,050 – 2000) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":579,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate concentration","parameters_en":[{"name":"Range","range":"(0,050 – 2000) mg/l"}],"search_en":"Water, wastewater Nitrate concentration Ion chromatography with conductometric detection (IC-CD) Range PN-EN ISO 10304-1:2009+AC:2012","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water, wastewater","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,050 – 2000) mg/l"}],"search_zh":"水、废水 硝酸盐浓度 离子色谱-电导检测法（IC-CD） 范围 PN-EN ISO 10304-1:2009+AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水、废水"},{"_id":"6a836fb9af14b9c0e7b1ed5b","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu azotanowego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu azotanowego (z obliczeń)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu azotanowego (z obliczeń) PN-EN ISO 10304-1:2009+AC:2012 Woda, scieki Stezenie azotu azotanowego (z obliczen) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":580,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate nitrogen concentration (calculated)","search_en":"Water, wastewater Nitrate nitrogen concentration (calculated) PN-EN ISO 10304-1:2009+AC:2012","test_object_en":"Water, wastewater","search_zh":"水、废水 硝酸盐氮浓度（由计算得出） PN-EN ISO 10304-1:2009+AC:2012","test_object_zh":"水、废水","methodology_zh":"硝酸盐氮浓度（由计算得出）"},{"_id":"6a836fb9af14b9c0e7b1ed5c","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotanów","parameters":[{"name":"Zakres","range":"(0,18 – 2200) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotanów\nZakres (0,18 – 2200) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotanów\nZakres (0,18 – 2200) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08 Woda, scieki Stezenie azotanow\nZakres (0,18 – 2200) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":581,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate concentration","parameters_en":[{"name":"Range","range":"(0,18 – 2200) mg/l"}],"search_en":"Water, wastewater Nitrate concentration Spectrophotometric method Range PN-82/C-04576/08","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,18 – 2200) mg/l"}],"search_zh":"水、废水 硝酸盐浓度 分光光度法 范围 PN-82/C-04576/08","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a836fb9af14b9c0e7b1ed5d","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu azotanowego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu azotanowego (z obliczeń)","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu azotanowego (z obliczeń) PN-82/C-04576/08 Woda, scieki Stezenie azotu azotanowego (z obliczen) PN-82/C-04576/08","categories":["water"],"row_index":582,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate nitrogen concentration (calculated)","search_en":"Water, wastewater Nitrate nitrogen concentration (calculated) PN-82/C-04576/08","test_object_en":"Water, wastewater","search_zh":"水、废水 硝酸盐氮浓度（由计算得出） PN-82/C-04576/08","test_object_zh":"水、废水","methodology_zh":"硝酸盐氮浓度（由计算得出）"},{"_id":"6a836fb9af14b9c0e7b1ed5e","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(3,4 – 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (3,4 – 1000) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001 z wyłączeniem pkt. 11.1","norm_bases":["PN-EN 25663:2001 z wyłączeniem pkt. 11.1"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu Kjeldahla\nZakres (3,4 – 1000) mg/l\nMetoda miareczkowa PN-EN 25663:2001 z wyłączeniem pkt. 11.1 Woda, scieki Stezenie azotu Kjeldahla\nZakres (3,4 – 1000) mg/l\nMetoda miareczkowa PN-EN 25663:2001 z wylaczeniem pkt. 11.1","categories":["water"],"row_index":583,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(3,4 – 1000) mg/l"}],"search_en":"Water, wastewater Kjeldahl nitrogen concentration Titrimetric method Range PN-EN 25663:2001 z wyłączeniem pkt. 11.1","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(3,4 – 1000) mg/l"}],"search_zh":"水、废水 凯氏氮浓度 滴定法 范围 PN-EN 25663:2001 z wyłączeniem pkt. 11.1","technique_zh":"滴定法","test_object_zh":"水、废水"},{"_id":"6a836fb9af14b9c0e7b1ed5f","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu ogólnego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"Metoda nr 047 Wydanie 5 z dnia 19.11.2019","norm_bases":["Metoda nr 047 Wydanie 5 z dnia 19.11.2019"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu ogólnego (z obliczeń) Metoda nr 047 Wydanie 5 z dnia 19.11.2019 Woda, scieki Stezenie azotu ogolnego (z obliczen) Metoda nr 047 Wydanie 5 z dnia 19.11.2019","categories":["water"],"row_index":584,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total nitrogen concentration (calculated)","search_en":"Water, wastewater Total nitrogen concentration (calculated) Metoda nr 047 Wydanie 5 z dnia 19.11.2019","test_object_en":"Water, wastewater","methodology_zh":"总氮浓度（计算值）","search_zh":"水、废水 总氮浓度（计算值） Metoda nr 047 Wydanie 5 z dnia 19.11.2019","test_object_zh":"水、废水"},{"_id":"6a836fb9af14b9c0e7b1ed60","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,47 – 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,47 – 1000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu amonowego\nZakres (0,47 – 1000) mg/l\nMetoda miareczkowa PN-ISO 5664:2002 Woda, scieki Stezenie azotu amonowego\nZakres (0,47 – 1000) mg/l\nMetoda miareczkowa PN-ISO 5664:2002","categories":["water"],"row_index":585,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,47 – 1000) mg/l"}],"search_en":"Water, wastewater Ammonium nitrogen concentration Titrimetric method Range PN-ISO 5664:2002","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,47 – 1000) mg/l"}],"search_zh":"水、废水 氨氮浓度 滴定法 范围 PN-ISO 5664:2002","technique_zh":"滴定法","test_object_zh":"水、废水"},{"_id":"6a836fb9af14b9c0e7b1ed61","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie jonu amonowego, amoniaku (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie jonu amonowego, amoniaku (z obliczeń)","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie jonu amonowego, amoniaku (z obliczeń) PN-ISO 5664:2002 Woda, scieki Stezenie jonu amonowego, amoniaku (z obliczen) PN-ISO 5664:2002","categories":["water"],"row_index":586,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of ammonium ion, ammonia (calculated)","search_en":"Water, wastewater Concentration of ammonium ion, ammonia (calculated) PN-ISO 5664:2002","test_object_en":"Water, wastewater","search_zh":"水、废水 铵离子、氨浓度（由计算得出） PN-ISO 5664:2002","test_object_zh":"水、废水","methodology_zh":"铵离子、氨浓度（由计算得出）"},{"_id":"6a836fb9af14b9c0e7b1ed62","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,050 – 5,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,050 – 5,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu amonowego\nZakres (0,050 – 5,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, scieki Stezenie azotu amonowego\nZakres (0,050 – 5,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":587,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,050 – 5,0) mg/l"}],"search_en":"Water, wastewater Ammonium nitrogen concentration Spectrophotometric method Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,050 – 5,0) mg/l"}],"search_zh":"水、废水 氨氮浓度 分光光度法 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a836fb9af14b9c0e7b1ed63","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie jonu amonowego, amoniaku (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie jonu amonowego, amoniaku (z obliczeń)","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie jonu amonowego, amoniaku (z obliczeń) PN-ISO 7150-1:2002 Woda, scieki Stezenie jonu amonowego, amoniaku (z obliczen) PN-ISO 7150-1:2002","categories":["water"],"row_index":588,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of ammonium ion, ammonia (calculated)","search_en":"Water, wastewater Concentration of ammonium ion, ammonia (calculated) PN-ISO 7150-1:2002","test_object_en":"Water, wastewater","search_zh":"水、废水 铵离子、氨浓度（由计算得出） PN-ISO 7150-1:2002","test_object_zh":"水、废水","methodology_zh":"铵离子、氨浓度（由计算得出）"},{"_id":"6a836fb9af14b9c0e7b1ed64","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,016 – 32) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,016 – 32) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010","norm_bases":["PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie fosforu ogólnego\nZakres (0,016 – 32) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 Woda, scieki Stezenie fosforu ogolnego\nZakres (0,016 – 32) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010","categories":["water"],"row_index":589,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,016 – 32) mg/l"}],"search_en":"Water, wastewater Total phosphorus concentration Spectrophotometric method Range PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,016 – 32) mg/l"}],"search_zh":"水、废水 总磷浓度 分光光度法 范围 PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a836fb9af14b9c0e7b1ed65","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie fosforanów","parameters":[{"name":"Zakres","range":"(0,050 – 100) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie fosforanów\nZakres (0,050 – 100) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie fosforanów\nZakres (0,050 – 100) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Woda, scieki Stezenie fosforanow\nZakres (0,050 – 100) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":590,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phosphate concentration","parameters_en":[{"name":"Range","range":"(0,050 – 100) mg/l"}],"search_en":"Water, wastewater Phosphate concentration Ion chromatography with conductometric detection (IC-CD) Range PN-EN ISO 10304-1:2009+AC:2012","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,050 – 100) mg/l"}],"search_zh":"水、废水 磷酸盐浓度 离子色谱-电导检测法（IC-CD） 范围 PN-EN ISO 10304-1:2009+AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水、废水","methodology_zh":"磷酸盐浓度"},{"_id":"6a836fb9af14b9c0e7b1ed66","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie żelaza","parameters":[{"name":"Zakres","range":"(0,010 – 10,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza\nZakres (0,010 – 10,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001+Ap1:2016-6","norm_bases":["PN-ISO 6332:2001+Ap1:2016-6"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie żelaza\nZakres (0,010 – 10,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-6 Woda, scieki Stezenie zelaza\nZakres (0,010 – 10,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-6","categories":["water"],"row_index":591,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Iron concentration","parameters_en":[{"name":"Range","range":"(0,010 – 10,0) mg/l"}],"search_en":"Water, wastewater Iron concentration Spectrophotometric method Range PN-ISO 6332:2001+Ap1:2016-6","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"铁浓度","parameters_zh":[{"name":"范围","range":"(0,010 – 10,0) mg/l"}],"search_zh":"水、废水 铁浓度 分光光度法 范围 PN-ISO 6332:2001+Ap1:2016-6","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a836fb9af14b9c0e7b1ed67","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie manganu","parameters":[{"name":"Zakres","range":"(0,030 – 4,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie manganu\nZakres (0,030 – 4,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-92/C-04590/03","norm_bases":["PN-92/C-04590/03"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie manganu\nZakres (0,030 – 4,0) mg/l\nMetoda spektrofotometryczna PN-92/C-04590/03 Woda, scieki Stezenie manganu\nZakres (0,030 – 4,0) mg/l\nMetoda spektrofotometryczna PN-92/C-04590/03","categories":["water"],"row_index":592,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Manganese concentration","parameters_en":[{"name":"Range","range":"(0,030 – 4,0) mg/l"}],"search_en":"Water, wastewater Manganese concentration Spectrophotometric method Range PN-92/C-04590/03","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(0,030 – 4,0) mg/l"}],"search_zh":"水、废水 锰浓度 分光光度法 范围 PN-92/C-04590/03","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a836fb9af14b9c0e7b1ed68","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie substancji ekstrahujących się eterem naftowym","parameters":[{"name":"Zakres","range":"(10 – 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie substancji ekstrahujących się eterem naftowym\nZakres (10 – 1000) mg/l\nMetoda wagowa","reference":"PN-86/C-04573/01","norm_bases":["PN-86/C-04573/01"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie substancji ekstrahujących się eterem naftowym\nZakres (10 – 1000) mg/l\nMetoda wagowa PN-86/C-04573/01 Woda, scieki Stezenie substancji ekstrahujacych sie eterem naftowym\nZakres (10 – 1000) mg/l\nMetoda wagowa PN-86/C-04573/01","categories":["water"],"row_index":593,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of substances extractable with petroleum ether","parameters_en":[{"name":"Range","range":"(10 – 1000) mg/l"}],"search_en":"Water, wastewater Concentration of substances extractable with petroleum ether Gravimetric method Range PN-86/C-04573/01","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(10 – 1000) mg/l"}],"search_zh":"水、废水 石油醚可萃取物浓度 重量法 范围 PN-86/C-04573/01","technique_zh":"重量法","test_object_zh":"水、废水","methodology_zh":"石油醚可萃取物浓度"},{"_id":"6a836fb9af14b9c0e7b1ed69","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu (BZT5)","parameters":[{"name":"Zakres","range":"(1 – 6000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu (BZT5)\nZakres (1 – 6000) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu (BZT5)\nZakres (1 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Woda, scieki Biochemiczne zapotrzebowanie tlenu (BZT5)\nZakres (1 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":594,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand (BOD5)","parameters_en":[{"name":"Range","range":"(1 – 6000) mg/l O2"}],"search_en":"Water, wastewater Biochemical oxygen demand (BOD5) Electrochemical method Range PN-EN ISO 5815-1:2019-12","technique_en":"Electrochemical method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(1 – 6000) mg/l O2"}],"search_zh":"水、废水 五日生化需氧量（BOD5） 电化学法 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"水、废水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a836fb9af14b9c0e7b1ed6a","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie tlenu rozpuszczonego","parameters":[{"name":"Zakres","range":"(0,2 – 10) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Stężenie tlenu rozpuszczonego\nZakres (0,2 – 10) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5814:2013-04","norm_bases":["PN-EN ISO 5814:2013-04"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie tlenu rozpuszczonego\nZakres (0,2 – 10) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5814:2013-04 Woda, scieki Stezenie tlenu rozpuszczonego\nZakres (0,2 – 10) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5814:2013-04","categories":["water"],"row_index":595,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissolved oxygen concentration","parameters_en":[{"name":"Range","range":"(0,2 – 10) mg/l O2"}],"search_en":"Water, wastewater Dissolved oxygen concentration Electrochemical method Range PN-EN ISO 5814:2013-04","technique_en":"Electrochemical method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,2 – 10) mg/l O2"}],"search_zh":"水、废水 溶解氧浓度 电化学法 范围 PN-EN ISO 5814:2013-04","technique_zh":"电化学法","test_object_zh":"水、废水","methodology_zh":"溶解氧浓度"},{"_id":"6a836fb9af14b9c0e7b1ed6b","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Chemiczne zapotrzebowanie tlenu – ChZT-Cr","parameters":[{"name":"Zakres","range":"(9,0 – 3000) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu – ChZT-Cr\nZakres (9,0 – 3000) mg/l O2\nMetoda miareczkowa","reference":"PN-74/C-04578-03","norm_bases":["PN-74/C-04578-03"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Chemiczne zapotrzebowanie tlenu – ChZT-Cr\nZakres (9,0 – 3000) mg/l O2\nMetoda miareczkowa PN-74/C-04578-03 Woda, scieki Chemiczne zapotrzebowanie tlenu – ChZT-Cr\nZakres (9,0 – 3000) mg/l O2\nMetoda miareczkowa PN-74/C-04578-03","categories":["water"],"row_index":596,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand – COD-Cr","parameters_en":[{"name":"Range","range":"(9,0 – 3000) mg/l O2"}],"search_en":"Water, wastewater Chemical oxygen demand – COD-Cr Titrimetric method Range PN-74/C-04578-03","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(9,0 – 3000) mg/l O2"}],"search_zh":"水、废水 化学需氧量（COD-Cr） 滴定法 范围 PN-74/C-04578-03","technique_zh":"滴定法","test_object_zh":"水、废水","methodology_zh":"化学需氧量（COD-Cr）"},{"_id":"6a836fb9af14b9c0e7b1ed6c","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Chemiczne zapotrzebowanie tlenu ChZT-Cr","parameters":[{"name":"Zakres","range":"(25 – 1000) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu ChZT-Cr\nZakres (25 – 1000) mg/l O2\nMetoda miareczkowa","reference":"PN-ISO 6060:2006","norm_bases":["PN-ISO 6060:2006"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Chemiczne zapotrzebowanie tlenu ChZT-Cr\nZakres (25 – 1000) mg/l O2\nMetoda miareczkowa PN-ISO 6060:2006 Woda, scieki Chemiczne zapotrzebowanie tlenu ChZT-Cr\nZakres (25 – 1000) mg/l O2\nMetoda miareczkowa PN-ISO 6060:2006","categories":["water"],"row_index":597,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand COD-Cr","parameters_en":[{"name":"Range","range":"(25 – 1000) mg/l O2"}],"search_en":"Water, wastewater Chemical oxygen demand COD-Cr Titrimetric method Range PN-ISO 6060:2006","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(25 – 1000) mg/l O2"}],"search_zh":"水、废水 化学需氧量 COD-Cr 滴定法 范围 PN-ISO 6060:2006","technique_zh":"滴定法","test_object_zh":"水、废水","methodology_zh":"化学需氧量 COD-Cr"},{"_id":"6a836fb9af14b9c0e7b1ed6d","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Chemiczne zapotrzebowanie tlenu ChZT-Cr","parameters":[{"name":"Zakres","range":"(10 – 10000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu ChZT-Cr\nZakres (10 – 10000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Chemiczne zapotrzebowanie tlenu ChZT-Cr\nZakres (10 – 10000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda, scieki Chemiczne zapotrzebowanie tlenu ChZT-Cr\nZakres (10 – 10000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":598,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand COD-Cr","parameters_en":[{"name":"Range","range":"(10 – 10000) mg/l O2"}],"search_en":"Water, wastewater Chemical oxygen demand COD-Cr Spectrophotometric method Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(10 – 10000) mg/l O2"}],"search_zh":"水、废水 化学需氧量 COD-Cr 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"化学需氧量 COD-Cr"},{"_id":"6a836fb9af14b9c0e7b1ed6e","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(0,050 – 5000) mg/l"}],"technique":"Metoda chromatografii jonowej (IC) z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej (IC) z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie siarczanów\nZakres (0,050 – 5000) mg/l\nMetoda chromatografii jonowej (IC) z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie siarczanów\nZakres (0,050 – 5000) mg/l\nMetoda chromatografii jonowej (IC) z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Woda, scieki Stezenie siarczanow\nZakres (0,050 – 5000) mg/l\nMetoda chromatografii jonowej (IC) z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":599,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Range","range":"(0,050 – 5000) mg/l"}],"search_en":"Water, wastewater Sulfate concentration Ion chromatography (IC) with conductometric detection (IC-CD) Range PN-EN ISO 10304-1:2009+AC:2012","technique_en":"Ion chromatography (IC) with conductometric detection (IC-CD)","test_object_en":"Water, wastewater","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,050 – 5000) mg/l"}],"search_zh":"水、废水 硫酸盐浓度 范围 PN-EN ISO 10304-1:2009+AC:2012","test_object_zh":"水、废水"},{"_id":"6a836fb9af14b9c0e7b1ed6f","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(0,10 – 5000) mg/l"}],"technique":"Metoda chromatografii jonowej (IC) z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej (IC) z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie chlorków\nZakres (0,10 – 5000) mg/l\nMetoda chromatografii jonowej (IC) z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie chlorków\nZakres (0,10 – 5000) mg/l\nMetoda chromatografii jonowej (IC) z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Woda, scieki Stezenie chlorkow\nZakres (0,10 – 5000) mg/l\nMetoda chromatografii jonowej (IC) z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":600,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(0,10 – 5000) mg/l"}],"search_en":"Water, wastewater Chloride concentration Ion chromatography (IC) with conductometric detection (IC-CD) Range PN-EN ISO 10304-1:2009+AC:2012","technique_en":"Ion chromatography (IC) with conductometric detection (IC-CD)","test_object_en":"Water, wastewater","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(0,10 – 5000) mg/l"}],"search_zh":"水、废水 氯化物浓度 范围 PN-EN ISO 10304-1:2009+AC:2012","test_object_zh":"水、废水"},{"_id":"6a836fb9af14b9c0e7b1ed70","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Indeks nadmanganianowy","parameters":[{"name":"Zakres","range":"(0,50 – 100) mg O2/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Indeks nadmanganianowy\nZakres (0,50 – 100) mg O2/l\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Indeks nadmanganianowy\nZakres (0,50 – 100) mg O2/l\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda, scieki Indeks nadmanganianowy\nZakres (0,50 – 100) mg O2/l\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":601,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Permanganate index","parameters_en":[{"name":"Range","range":"(0,50 – 100) mg O2/l"}],"search_en":"Water, wastewater Permanganate index Titrimetric method Range PN-EN ISO 8467:2001","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","methodology_zh":"高锰酸盐指数","parameters_zh":[{"name":"范围","range":"(0,50 – 100) mg O2/l"}],"search_zh":"水、废水 高锰酸盐指数 滴定法 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"水、废水"},{"_id":"6a836fb9af14b9c0e7b1ed71","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie glinu","parameters":[{"name":"Zakres","range":"(0,0100 – 10,0) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie glinu\nZakres (0,0100 – 10,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie glinu\nZakres (0,0100 – 10,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Woda, scieki Stezenie glinu\nZakres (0,0100 – 10,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["water"],"row_index":602,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Aluminium concentration","parameters_en":[{"name":"Range","range":"(0,0100 – 10,0) mg/l"}],"search_en":"Water, wastewater Aluminium concentration Inductively coupled plasma optical emission spectrometry (ICP-OES) Range PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,0100 – 10,0) mg/l"}],"search_zh":"水、废水 铝浓度 电感耦合等离子体原子发射光谱法（ICP-OES） 范围 PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"水、废水","methodology_zh":"铝浓度"},{"_id":"6a836fb9af14b9c0e7b1ed72","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)","parameters":[{"name":"Zakres","range":"(0,050 – 40) mmol/l"},{"name":"Zakres","range":"(5,0 – 4000) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres:\nZakres (0,050 – 40) mmol/l\nZakres (5,0 – 4000) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres:\nZakres (0,050 – 40) mmol/l\nZakres (5,0 – 4000) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999 Woda, scieki Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna)\nZakres:\nZakres (0,050 – 40) mmol/l\nZakres (5,0 – 4000) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":603,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total content of calcium and magnesium (total hardness)","parameters_en":[{"name":"Range","range":"(0,050 – 40) mmol/l"},{"name":"Range","range":"(5,0 – 4000) mg/l CaCO3"}],"search_en":"Water, wastewater Total content of calcium and magnesium (total hardness) Titrimetric method Range Range PN-ISO 6059:1999","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","methodology_zh":"钙与镁总量（总硬度）","parameters_zh":[{"name":"范围","range":"(0,050 – 40) mmol/l"},{"name":"范围","range":"(5,0 – 4000) mg/l CaCO3"}],"search_zh":"水、废水 钙与镁总量（总硬度） 滴定法 范围 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"水、废水"},{"_id":"6a836fb9af14b9c0e7b1ed73","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie wapnia","parameters":[{"name":"Zakres","range":"(0,050 – 25) mmol/l"},{"name":"Zakres","range":"(2,0 – 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie wapnia\nZakres:\nZakres (0,050 – 25) mmol/l\nZakres (2,0 – 1000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 6058:1999","norm_bases":["PN-ISO 6058:1999"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie wapnia\nZakres:\nZakres (0,050 – 25) mmol/l\nZakres (2,0 – 1000) mg/l\nMetoda miareczkowa PN-ISO 6058:1999 Woda, scieki Stezenie wapnia\nZakres:\nZakres (0,050 – 25) mmol/l\nZakres (2,0 – 1000) mg/l\nMetoda miareczkowa PN-ISO 6058:1999","categories":["water"],"row_index":604,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Calcium concentration","parameters_en":[{"name":"Range","range":"(0,050 – 25) mmol/l"},{"name":"Range","range":"(2,0 – 1000) mg/l"}],"search_en":"Water, wastewater Calcium concentration Titrimetric method Range Range PN-ISO 6058:1999","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,050 – 25) mmol/l"},{"name":"范围","range":"(2,0 – 1000) mg/l"}],"search_zh":"水、废水 钙浓度 滴定法 范围 范围 PN-ISO 6058:1999","technique_zh":"滴定法","test_object_zh":"水、废水","methodology_zh":"钙浓度"},{"_id":"6a836fb9af14b9c0e7b1ed74","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie magnezu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie magnezu (z obliczeń)","reference":"PN-C 04554-4:1999 Załącznik A","norm_bases":["PN-C 04554-4:1999 Załącznik A"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie magnezu (z obliczeń) PN-C 04554-4:1999 Załącznik A Woda, scieki Stezenie magnezu (z obliczen) PN-C 04554-4:1999 Zalacznik A","categories":["water"],"row_index":605,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnesium concentration (calculated)","search_en":"Water, wastewater Magnesium concentration (calculated) PN-C 04554-4:1999 Załącznik A","test_object_en":"Water, wastewater","search_zh":"水、废水 镁浓度（计算值） PN-C 04554-4:1999 Załącznik A","test_object_zh":"水、废水","methodology_zh":"镁浓度（计算值）"},{"_id":"6a836fb9af14b9c0e7b1ed75","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(20 – 5000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie siarczanów\nZakres (20 – 5000) mg/l\nMetoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie siarczanów\nZakres (20 – 5000) mg/l\nMetoda wagowa PN-ISO 9280:2002 Woda, scieki Stezenie siarczanow\nZakres (20 – 5000) mg/l\nMetoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":606,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Range","range":"(20 – 5000) mg/l"}],"search_en":"Water, wastewater Sulfate concentration Gravimetric method Range PN-ISO 9280:2002","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(20 – 5000) mg/l"}],"search_zh":"水、废水 硫酸盐浓度 重量法 范围 PN-ISO 9280:2002","technique_zh":"重量法","test_object_zh":"水、废水"},{"_id":"6a836fb9af14b9c0e7b1ed76","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5 – 25 000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5 – 25 000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie chlorków\nZakres (5 – 25 000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda, scieki Stezenie chlorkow\nZakres (5 – 25 000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":607,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5 – 25 000) mg/l"}],"search_en":"Water, wastewater Chloride concentration Titrimetric method Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5 – 25 000) mg/l"}],"search_zh":"水、废水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水、废水"},{"_id":"6a836fb9af14b9c0e7b1ed77","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Indeks oleju mineralnego","parameters":[{"name":"Zakres","range":"(0,10 – 100) mg/l"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Indeks oleju mineralnego\nZakres (0,10 – 100) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN ISO 9377-2:2003","norm_bases":["PN-EN ISO 9377-2:2003"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Indeks oleju mineralnego\nZakres (0,10 – 100) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN ISO 9377-2:2003 Woda, scieki Indeks oleju mineralnego\nZakres (0,10 – 100) mg/l\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN ISO 9377-2:2003","categories":["water","petro"],"row_index":608,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mineral oil index","parameters_en":[{"name":"Range","range":"(0,10 – 100) mg/l"}],"search_en":"Water, wastewater Mineral oil index Gas chromatography with flame ionization detection (GC-FID) Range PN-EN ISO 9377-2:2003","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,10 – 100) mg/l"}],"search_zh":"水、废水 矿物油指数 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-EN ISO 9377-2:2003","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"水、废水","methodology_zh":"矿物油指数"},{"_id":"6a836fb9af14b9c0e7b1ed78","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie chlorku winylu","parameters":[{"name":"Zakres","range":"(0,10 – 1,0) mg/l"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie chlorku winylu\nZakres (0,10 – 1,0) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Metoda nr 192 Wydanie 1 z dnia 26.09.2019","norm_bases":["Metoda nr 192 Wydanie 1 z dnia 26.09.2019"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie chlorku winylu\nZakres (0,10 – 1,0) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Metoda nr 192 Wydanie 1 z dnia 26.09.2019 Woda, scieki Stezenie chlorku winylu\nZakres (0,10 – 1,0) mg/l\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Metoda nr 192 Wydanie 1 z dnia 26.09.2019","categories":["water"],"row_index":609,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Vinyl chloride concentration","parameters_en":[{"name":"Range","range":"(0,10 – 1,0) mg/l"}],"search_en":"Water, wastewater Vinyl chloride concentration Gas chromatography with flame ionization detection (GC-FID) Range Metoda nr 192 Wydanie 1 z dnia 26.09.2019","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,10 – 1,0) mg/l"}],"search_zh":"水、废水 氯乙烯浓度 气相色谱-氢火焰离子化检测法（GC-FID） 范围 Metoda nr 192 Wydanie 1 z dnia 26.09.2019","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"水、废水","methodology_zh":"氯乙烯浓度"},{"_id":"6a836fb9af14b9c0e7b1ed79","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie chlorowcowych pochodnych węglowodorów","parameters":[{"name":"Zakres","range":"1,2-dichloroetan (0,0010 – 0,10) mg/l"},{"name":"Tetrachlorometan","range":"(0,00050–0,10) mg/l"},{"name":"Tetrachloroetylen","range":"(0,0010 –0,10) mg/l"},{"name":"trichloroetylen","range":"(0,0010 –0,10) mg/l"},{"name":"trichlorometan","range":"(0,0010 –0,10) mg/l"},{"name":"heksachlorobutadien","range":"(0,00010 – 0,010) mg/l"}],"technique":"Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","techniques":["Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)"],"computed":[],"activity":"Stężenie chlorowcowych pochodnych węglowodorów\nZakres:\nZakres 1,2-dichloroetan (0,0010 – 0,10) mg/l\nTetrachlorometan (0,00050–0,10) mg/l\nTetrachloroetylen (0,0010 –0,10) mg/l\ntrichloroetylen (0,0010 –0,10) mg/l\ntrichlorometan (0,0010 –0,10) mg/l\nheksachlorobutadien (0,00010 – 0,010) mg/l\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","reference":"PN-EN ISO 10301:2002","norm_bases":["PN-EN ISO 10301:2002"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie chlorowcowych pochodnych węglowodorów\nZakres:\nZakres 1,2-dichloroetan (0,0010 – 0,10) mg/l\nTetrachlorometan (0,00050–0,10) mg/l\nTetrachloroetylen (0,0010 –0,10) mg/l\ntrichloroetylen (0,0010 –0,10) mg/l\ntrichlorometan (0,0010 –0,10) mg/l\nheksachlorobutadien (0,00010 – 0,010) mg/l\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) PN-EN ISO 10301:2002 Woda, scieki Stezenie chlorowcowych pochodnych weglowodorow\nZakres:\nZakres 1,2-dichloroetan (0,0010 – 0,10) mg/l\nTetrachlorometan (0,00050–0,10) mg/l\nTetrachloroetylen (0,0010 –0,10) mg/l\ntrichloroetylen (0,0010 –0,10) mg/l\ntrichlorometan (0,0010 –0,10) mg/l\nheksachlorobutadien (0,00010 – 0,010) mg/l\nMetoda chromatografii gazowej z detekcja wychwytu elektronow (GC-ECD) PN-EN ISO 10301:2002","categories":["water"],"row_index":610,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of halogenated hydrocarbon derivatives","parameters_en":[{"name":"Range","range":"1,2-dichloroetan (0,0010 – 0,10) mg/l"},{"name":"Tetrachloromethane","range":"(0,00050–0,10) mg/l"},{"name":"Tetrachloroethylene","range":"(0,0010 –0,10) mg/l"},{"name":"trichloroethylene","range":"(0,0010 –0,10) mg/l"},{"name":"trichloromethane","range":"(0,0010 –0,10) mg/l"},{"name":"hexachlorobutadiene","range":"(0,00010 – 0,010) mg/l"}],"search_en":"Water, wastewater Concentration of halogenated hydrocarbon derivatives Gas chromatography with electron capture detection (GC-ECD) Range Tetrachloromethane Tetrachloroethylene trichloroethylene trichloromethane hexachlorobutadiene PN-EN ISO 10301:2002","technique_en":"Gas chromatography with electron capture detection (GC-ECD)","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"1,2-dichloroetan (0,0010 – 0,10) mg/l"},{"name":"四氯化碳","range":"(0,00050–0,10) mg/l"},{"name":"Tetrachloroetylen","range":"(0,0010 –0,10) mg/l"},{"name":"三氯乙烯","range":"(0,0010 –0,10) mg/l"},{"name":"三氯甲烷","range":"(0,0010 –0,10) mg/l"},{"name":"六氯丁二烯","range":"(0,00010 – 0,010) mg/l"}],"search_zh":"水、废水 卤代烃浓度 气相色谱-电子捕获检测法（GC-ECD） 范围 四氯化碳 三氯乙烯 三氯甲烷 六氯丁二烯 PN-EN ISO 10301:2002","technique_zh":"气相色谱-电子捕获检测法（GC-ECD）","test_object_zh":"水、废水","methodology_zh":"卤代烃浓度"},{"_id":"6a836fb9af14b9c0e7b1ed7a","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie ogólnego węgla","parameters":[{"name":"organicznego (OWO) i rozpuszczonego węgla"},{"name":"organicznego (RWO)"},{"name":"Zakres","range":"(0,30 – 1000) mg/l"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Stężenie ogólnego węgla\nZakres:\norganicznego (OWO) i rozpuszczonego węgla\norganicznego (RWO)\nZakres (0,30 – 1000) mg/l\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN 1484:1999","norm_bases":["PN-EN 1484:1999"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie ogólnego węgla\nZakres:\norganicznego (OWO) i rozpuszczonego węgla\norganicznego (RWO)\nZakres (0,30 – 1000) mg/l\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN 1484:1999 Woda, scieki Stezenie ogolnego wegla\nZakres:\norganicznego (OWO) i rozpuszczonego wegla\norganicznego (RWO)\nZakres (0,30 – 1000) mg/l\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN 1484:1999","categories":["water"],"row_index":611,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total carbon concentration","parameters_en":[{"name":"organic (TOC) and dissolved carbon"},{"name":"organic (DOC)"},{"name":"Range","range":"(0,30 – 1000) mg/l"}],"search_en":"Water, wastewater Total carbon concentration High-temperature combustion with IR detection organic (TOC) and dissolved carbon organic (DOC) Range PN-EN 1484:1999","technique_en":"High-temperature combustion with IR detection","test_object_en":"Water, wastewater","parameters_zh":[{"name":"organicznego (OWO) i rozpuszczonego węgla"},{"name":"有机的（溶解性有机碳 DOC）"},{"name":"范围","range":"(0,30 – 1000) mg/l"}],"search_zh":"水、废水 总碳浓度 高温燃烧红外检测法 有机的（溶解性有机碳 DOC） 范围 PN-EN 1484:1999","technique_zh":"高温燃烧红外检测法","test_object_zh":"水、废水","methodology_zh":"总碳浓度"},{"_id":"6a836fb9af14b9c0e7b1ed7b","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie stałych związków rozpuszczonych (TDS)","parameters":[{"name":"Zakres","range":"(10,0 – 5000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie stałych związków rozpuszczonych (TDS)\nZakres (10,0 – 5000) mg/l\nMetoda wagowa","reference":"PN-EN 15216:2022-03","norm_bases":["PN-EN 15216:2022-03"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie stałych związków rozpuszczonych (TDS)\nZakres (10,0 – 5000) mg/l\nMetoda wagowa PN-EN 15216:2022-03 Woda, scieki Stezenie stalych zwiazkow rozpuszczonych (TDS)\nZakres (10,0 – 5000) mg/l\nMetoda wagowa PN-EN 15216:2022-03","categories":["water"],"row_index":612,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total dissolved solids concentration (TDS)","parameters_en":[{"name":"Range","range":"(10,0 – 5000) mg/l"}],"search_en":"Water, wastewater Total dissolved solids concentration (TDS) Gravimetric method Range PN-EN 15216:2022-03","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(10,0 – 5000) mg/l"}],"search_zh":"水、废水 重量法 范围 PN-EN 15216:2022-03","technique_zh":"重量法","test_object_zh":"水、废水"},{"_id":"6a836fb9af14b9c0e7b1ed7c","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie chloru ogólnego (całkowitego)","parameters":[{"name":"Zakres","range":"(0,030 – 5) mg/l"},{"name":"Stężenie chloru wolnego"},{"name":"Zakres","range":"(0,030 – 3,5) mg/l"},{"name":"Chlor związany (z obliczeń)"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chloru ogólnego (całkowitego)\nZakres:\nZakres (0,030 – 5) mg/l\nStężenie chloru wolnego\nZakres (0,030 – 3,5) mg/l\nChlor związany (z obliczeń)\nMetoda miareczkowa","reference":"PN-EN ISO 7393-1:2011","norm_bases":["PN-EN ISO 7393-1:2011"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie chloru ogólnego (całkowitego)\nZakres:\nZakres (0,030 – 5) mg/l\nStężenie chloru wolnego\nZakres (0,030 – 3,5) mg/l\nChlor związany (z obliczeń)\nMetoda miareczkowa PN-EN ISO 7393-1:2011 Woda, scieki Stezenie chloru ogolnego (calkowitego)\nZakres:\nZakres (0,030 – 5) mg/l\nStezenie chloru wolnego\nZakres (0,030 – 3,5) mg/l\nChlor zwiazany (z obliczen)\nMetoda miareczkowa PN-EN ISO 7393-1:2011","categories":["water"],"row_index":613,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total chlorine concentration","parameters_en":[{"name":"Range","range":"(0,030 – 5) mg/l"},{"name":"Free chlorine concentration"},{"name":"Range","range":"(0,030 – 3,5) mg/l"},{"name":"Combined chlorine (calculated)"}],"search_en":"Water, wastewater Total chlorine concentration Titrimetric method Range Free chlorine concentration Range Combined chlorine (calculated) PN-EN ISO 7393-1:2011","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,030 – 5) mg/l"},{"name":"游离氯浓度"},{"name":"范围","range":"(0,030 – 3,5) mg/l"},{"name":"化合氯（由计算得出）"}],"search_zh":"水、废水 总氯浓度 滴定法 范围 游离氯浓度 范围 化合氯（由计算得出） PN-EN ISO 7393-1:2011","technique_zh":"滴定法","test_object_zh":"水、废水","methodology_zh":"总氯浓度"},{"_id":"6a836fb9af14b9c0e7b1ed7d","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie heksachlorobenzenu","parameters":[{"name":"Zakres","range":"(0,010 – 0,10) μg/l"}],"technique":"Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","techniques":["Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)"],"computed":[],"activity":"Stężenie heksachlorobenzenu\nZakres (0,010 – 0,10) μg/l\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","reference":"PN-EN ISO 6468:2002","norm_bases":["PN-EN ISO 6468:2002"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie heksachlorobenzenu\nZakres (0,010 – 0,10) μg/l\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) PN-EN ISO 6468:2002 Woda, scieki Stezenie heksachlorobenzenu\nZakres (0,010 – 0,10) μg/l\nMetoda chromatografii gazowej z detekcja wychwytu elektronow (GC-ECD) PN-EN ISO 6468:2002","categories":["water"],"row_index":614,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hexachlorobenzene concentration","parameters_en":[{"name":"Range","range":"(0,010 – 0,10) μg/l"}],"search_en":"Water, wastewater Hexachlorobenzene concentration Gas chromatography with electron capture detection (GC-ECD) Range PN-EN ISO 6468:2002","technique_en":"Gas chromatography with electron capture detection (GC-ECD)","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,010 – 0,10) μg/l"}],"search_zh":"水、废水 气相色谱-电子捕获检测法（GC-ECD） 范围 PN-EN ISO 6468:2002","technique_zh":"气相色谱-电子捕获检测法（GC-ECD）","test_object_zh":"水、废水"},{"_id":"6a836fb9af14b9c0e7b1ed7e","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie węglowodorów aromatycznych","parameters":[{"name":"benzen","range":"(0,0010 – 100) mg/l"},{"name":"toluen","range":"(0,0010 – 100) mg/l"},{"name":"etylobenzen","range":"(0,0010 – 100) mg/l"},{"name":"styren","range":"(0,0010 – 100) mg/l"},{"name":"o-ksylen","range":"(0,0010 – 100) mg/l"},{"name":"(m+p)-ksylen","range":"(0,0020 – 200) mg/l"}],"technique":"Metoda chromatografii gazowej ze statyczną analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID)","techniques":["Metoda chromatografii gazowej ze statyczną analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID)"],"computed":[],"activity":"Stężenie węglowodorów aromatycznych\nZakres:\nbenzen (0,0010 – 100) mg/l\ntoluen (0,0010 – 100) mg/l\netylobenzen (0,0010 – 100) mg/l\nstyren (0,0010 – 100) mg/l\no-ksylen (0,0010 – 100) mg/l\n(m+p)-ksylen (0,0020 – 200) mg/l\nMetoda chromatografii gazowej ze statyczną analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID)","reference":"PN-ISO 11423-1:2002","norm_bases":["PN-ISO 11423-1:2002"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie węglowodorów aromatycznych\nZakres:\nbenzen (0,0010 – 100) mg/l\ntoluen (0,0010 – 100) mg/l\netylobenzen (0,0010 – 100) mg/l\nstyren (0,0010 – 100) mg/l\no-ksylen (0,0010 – 100) mg/l\n(m+p)-ksylen (0,0020 – 200) mg/l\nMetoda chromatografii gazowej ze statyczną analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID) PN-ISO 11423-1:2002 Woda, scieki Stezenie weglowodorow aromatycznych\nZakres:\nbenzen (0,0010 – 100) mg/l\ntoluen (0,0010 – 100) mg/l\netylobenzen (0,0010 – 100) mg/l\nstyren (0,0010 – 100) mg/l\no-ksylen (0,0010 – 100) mg/l\n(m+p)-ksylen (0,0020 – 200) mg/l\nMetoda chromatografii gazowej ze statyczna analiza fazy nadpowierzchniowej i detekcja plomieniowo-jonizacyjna (HS-GC-FID) PN-ISO 11423-1:2002","categories":["water"],"row_index":615,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of aromatic hydrocarbons","parameters_en":[{"name":"benzene","range":"(0,0010 – 100) mg/l"},{"name":"toluene","range":"(0,0010 – 100) mg/l"},{"name":"ethylbenzene","range":"(0,0010 – 100) mg/l"},{"name":"styrene","range":"(0,0010 – 100) mg/l"},{"name":"o-xylene","range":"(0,0010 – 100) mg/l"},{"name":"(m+p)-xylene","range":"(0,0020 – 200) mg/l"}],"search_en":"Water, wastewater Concentration of aromatic hydrocarbons Gas chromatography with static headspace analysis and flame ionization detection (HS-GC-FID) benzene toluene ethylbenzene styrene o-xylene (m+p)-xylene PN-ISO 11423-1:2002","technique_en":"Gas chromatography with static headspace analysis and flame ionization detection (HS-GC-FID)","test_object_en":"Water, wastewater","search_zh":"水、废水 芳香烃浓度 苯 甲苯 乙苯 苯乙烯 邻二甲苯 (间+对)-二甲苯 PN-ISO 11423-1:2002","test_object_zh":"水、废水","parameters_zh":[{"name":"苯","range":"(0,0010 – 100) mg/l"},{"name":"甲苯","range":"(0,0010 – 100) mg/l"},{"name":"乙苯","range":"(0,0010 – 100) mg/l"},{"name":"苯乙烯","range":"(0,0010 – 100) mg/l"},{"name":"邻二甲苯","range":"(0,0010 – 100) mg/l"},{"name":"(间+对)-二甲苯","range":"(0,0020 – 200) mg/l"}],"methodology_zh":"芳香烃浓度"},{"_id":"6a836fb9af14b9c0e7b1ed7f","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Suma węglowodorów aromatycznych (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma węglowodorów aromatycznych (z obliczeń)","reference":"PN-ISO 11423-1:2002","norm_bases":["PN-ISO 11423-1:2002"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Suma węglowodorów aromatycznych (z obliczeń) PN-ISO 11423-1:2002 Woda, scieki Suma weglowodorow aromatycznych (z obliczen) PN-ISO 11423-1:2002","categories":["water"],"row_index":616,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of aromatic hydrocarbons (calculated)","search_en":"Water, wastewater Sum of aromatic hydrocarbons (calculated) PN-ISO 11423-1:2002","test_object_en":"Water, wastewater","search_zh":"水、废水 芳香烃总量（由计算得出） PN-ISO 11423-1:2002","test_object_zh":"水、废水","methodology_zh":"芳香烃总量（由计算得出）"},{"_id":"6a836fb9af14b9c0e7b1ed80","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie trihalometanów","parameters":[{"name":"chloroform","range":"(1,0- 250) μg/l"},{"name":"chlorodibromometan","range":"(1,0- 250) μg/l"},{"name":"dichlorobromometan","range":"(1,0- 250) μg/l"},{"name":"bromoform","range":"(1,0- 250) μg/l"}],"technique":"Metoda chromatografii gazowej ze statyczną analizą fazy nadpowierzchniowej i detekcją wychwytu elektronów (HS-GC-ECD)","techniques":["Metoda chromatografii gazowej ze statyczną analizą fazy nadpowierzchniowej i detekcją wychwytu elektronów (HS-GC-ECD)"],"computed":[],"activity":"Stężenie trihalometanów\nZakres:\nchloroform (1,0- 250) μg/l\nchlorodibromometan (1,0- 250) μg/l\ndichlorobromometan (1,0- 250) μg/l\nbromoform (1,0- 250) μg/l\nMetoda chromatografii gazowej ze statyczną analizą fazy nadpowierzchniowej i detekcją wychwytu elektronów (HS-GC-ECD)","reference":"PN-EN ISO 10301:2002","norm_bases":["PN-EN ISO 10301:2002"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie trihalometanów\nZakres:\nchloroform (1,0- 250) μg/l\nchlorodibromometan (1,0- 250) μg/l\ndichlorobromometan (1,0- 250) μg/l\nbromoform (1,0- 250) μg/l\nMetoda chromatografii gazowej ze statyczną analizą fazy nadpowierzchniowej i detekcją wychwytu elektronów (HS-GC-ECD) PN-EN ISO 10301:2002 Woda, scieki Stezenie trihalometanow\nZakres:\nchloroform (1,0- 250) μg/l\nchlorodibromometan (1,0- 250) μg/l\ndichlorobromometan (1,0- 250) μg/l\nbromoform (1,0- 250) μg/l\nMetoda chromatografii gazowej ze statyczna analiza fazy nadpowierzchniowej i detekcja wychwytu elektronow (HS-GC-ECD) PN-EN ISO 10301:2002","categories":["water"],"row_index":617,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Trihalomethane concentration","parameters_en":[{"name":"chloroform","range":"(1,0- 250) μg/l"},{"name":"chlorodibromomethane","range":"(1,0- 250) μg/l"},{"name":"dichlorobromomethane","range":"(1,0- 250) μg/l"},{"name":"bromoform","range":"(1,0- 250) μg/l"}],"search_en":"Water, wastewater Trihalomethane concentration Gas chromatography with static headspace analysis and electron capture detection (HS-GC-ECD) chloroform chlorodibromomethane dichlorobromomethane bromoform PN-EN ISO 10301:2002","technique_en":"Gas chromatography with static headspace analysis and electron capture detection (HS-GC-ECD)","test_object_en":"Water, wastewater","search_zh":"水、废水 三氯甲烷 三溴甲烷 PN-EN ISO 10301:2002","test_object_zh":"水、废水","parameters_zh":[{"name":"三氯甲烷","range":"(1,0- 250) μg/l"},{"name":"chlorodibromometan","range":"(1,0- 250) μg/l"},{"name":"dichlorobromometan","range":"(1,0- 250) μg/l"},{"name":"三溴甲烷","range":"(1,0- 250) μg/l"}]},{"_id":"6a836fb9af14b9c0e7b1ed81","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Suma trihalometanów (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma trihalometanów (z obliczeń)","reference":"PN-EN ISO 10301:2002","norm_bases":["PN-EN ISO 10301:2002"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Suma trihalometanów (z obliczeń) PN-EN ISO 10301:2002 Woda, scieki Suma trihalometanow (z obliczen) PN-EN ISO 10301:2002","categories":["water"],"row_index":618,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of trihalomethanes (calculated)","search_en":"Water, wastewater Sum of trihalomethanes (calculated) PN-EN ISO 10301:2002","test_object_en":"Water, wastewater","search_zh":"水、废水 PN-EN ISO 10301:2002","test_object_zh":"水、废水"},{"_id":"6a836fb9af14b9c0e7b1ed82","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie chlorowcowych pochodnych węglowodorów","parameters":[{"name":"Zakres","range":"1,2-dichloroetan (0,25 – 10) μg/l"},{"name":"tetrachlorometan","range":"(0,10 – 10) μg/l"},{"name":"tetrachloroetylen","range":"(0,10 – 10) μg/l"},{"name":"trichloroetylen","range":"(0,10 – 10) μg/l"},{"name":"trichlorometan","range":"(0,25 – 10) μg/l"}],"technique":"Metoda chromatografii gazowej ze statyczną analizą fazy nadpowierzchniowej i detekcją wychwytu elektronów (HS-GC-ECD)","techniques":["Metoda chromatografii gazowej ze statyczną analizą fazy nadpowierzchniowej i detekcją wychwytu elektronów (HS-GC-ECD)"],"computed":[],"activity":"Stężenie chlorowcowych pochodnych węglowodorów\nZakres:\nZakres 1,2-dichloroetan (0,25 – 10) μg/l\ntetrachlorometan (0,10 – 10) μg/l\ntetrachloroetylen (0,10 – 10) μg/l\ntrichloroetylen (0,10 – 10) μg/l\ntrichlorometan (0,25 – 10) μg/l\nMetoda chromatografii gazowej ze statyczną analizą fazy nadpowierzchniowej i detekcją wychwytu elektronów (HS-GC-ECD)","reference":"PN-EN ISO 10301:2002","norm_bases":["PN-EN ISO 10301:2002"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie chlorowcowych pochodnych węglowodorów\nZakres:\nZakres 1,2-dichloroetan (0,25 – 10) μg/l\ntetrachlorometan (0,10 – 10) μg/l\ntetrachloroetylen (0,10 – 10) μg/l\ntrichloroetylen (0,10 – 10) μg/l\ntrichlorometan (0,25 – 10) μg/l\nMetoda chromatografii gazowej ze statyczną analizą fazy nadpowierzchniowej i detekcją wychwytu elektronów (HS-GC-ECD) PN-EN ISO 10301:2002 Woda, scieki Stezenie chlorowcowych pochodnych weglowodorow\nZakres:\nZakres 1,2-dichloroetan (0,25 – 10) μg/l\ntetrachlorometan (0,10 – 10) μg/l\ntetrachloroetylen (0,10 – 10) μg/l\ntrichloroetylen (0,10 – 10) μg/l\ntrichlorometan (0,25 – 10) μg/l\nMetoda chromatografii gazowej ze statyczna analiza fazy nadpowierzchniowej i detekcja wychwytu elektronow (HS-GC-ECD) PN-EN ISO 10301:2002","categories":["water"],"row_index":619,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of halogenated hydrocarbon derivatives","parameters_en":[{"name":"Range","range":"1,2-dichloroetan (0,25 – 10) μg/l"},{"name":"tetrachloromethane","range":"(0,10 – 10) μg/l"},{"name":"tetrachloroethylene","range":"(0,10 – 10) μg/l"},{"name":"trichloroethylene","range":"(0,10 – 10) μg/l"},{"name":"trichloromethane","range":"(0,25 – 10) μg/l"}],"search_en":"Water, wastewater Concentration of halogenated hydrocarbon derivatives Gas chromatography with static headspace analysis and electron capture detection (HS-GC-ECD) Range tetrachloromethane tetrachloroethylene trichloroethylene trichloromethane PN-EN ISO 10301:2002","technique_en":"Gas chromatography with static headspace analysis and electron capture detection (HS-GC-ECD)","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"1,2-dichloroetan (0,25 – 10) μg/l"},{"name":"四氯化碳","range":"(0,10 – 10) μg/l"},{"name":"四氯乙烯","range":"(0,10 – 10) μg/l"},{"name":"三氯乙烯","range":"(0,10 – 10) μg/l"},{"name":"三氯甲烷","range":"(0,25 – 10) μg/l"}],"search_zh":"水、废水 卤代烃浓度 范围 四氯化碳 四氯乙烯 三氯乙烯 三氯甲烷 PN-EN ISO 10301:2002","test_object_zh":"水、废水","methodology_zh":"卤代烃浓度"},{"_id":"6a836fb9af14b9c0e7b1ed83","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Suma tetrachloroetylenu i trichloroetylenu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma tetrachloroetylenu i trichloroetylenu (z obliczeń)","reference":"PN-EN ISO 10301:2002","norm_bases":["PN-EN ISO 10301:2002"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Suma tetrachloroetylenu i trichloroetylenu (z obliczeń) PN-EN ISO 10301:2002 Woda, scieki Suma tetrachloroetylenu i trichloroetylenu (z obliczen) PN-EN ISO 10301:2002","categories":["water"],"row_index":620,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of tetrachloroethylene and trichloroethylene (calculated)","search_en":"Water, wastewater Sum of tetrachloroethylene and trichloroethylene (calculated) PN-EN ISO 10301:2002","test_object_en":"Water, wastewater","search_zh":"水、废水 PN-EN ISO 10301:2002","test_object_zh":"水、废水"},{"_id":"6a836fb9af14b9c0e7b1ed84","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie chlorowcowych pochodnych węglowodorów","parameters":[{"name":"chlorek winylu","range":"(0,25 – 100) μg/l"},{"name":"Zakres","range":"1,2-dichloroetan (0,010 – 20) mg/l"},{"name":"tetrachlorometan","range":"(0,010 – 20) mg/l"},{"name":"tetrachloroetylen","range":"(0,010 – 20) mg/l"},{"name":"trichloroetylen","range":"(0,010 – 20) mg/l"},{"name":"trichlorometan","range":"(0,010 – 20) mg/l"}],"technique":"Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID)","techniques":["Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID)"],"computed":[],"activity":"Stężenie chlorowcowych pochodnych węglowodorów\nZakres:\nchlorek winylu (0,25 – 100) μg/l\nZakres 1,2-dichloroetan (0,010 – 20) mg/l\ntetrachlorometan (0,010 – 20) mg/l\ntetrachloroetylen (0,010 – 20) mg/l\ntrichloroetylen (0,010 – 20) mg/l\ntrichlorometan (0,010 – 20) mg/l\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID)","reference":"PN-EN ISO 10301:2002","norm_bases":["PN-EN ISO 10301:2002"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie chlorowcowych pochodnych węglowodorów\nZakres:\nchlorek winylu (0,25 – 100) μg/l\nZakres 1,2-dichloroetan (0,010 – 20) mg/l\ntetrachlorometan (0,010 – 20) mg/l\ntetrachloroetylen (0,010 – 20) mg/l\ntrichloroetylen (0,010 – 20) mg/l\ntrichlorometan (0,010 – 20) mg/l\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID) PN-EN ISO 10301:2002 Woda, scieki Stezenie chlorowcowych pochodnych weglowodorow\nZakres:\nchlorek winylu (0,25 – 100) μg/l\nZakres 1,2-dichloroetan (0,010 – 20) mg/l\ntetrachlorometan (0,010 – 20) mg/l\ntetrachloroetylen (0,010 – 20) mg/l\ntrichloroetylen (0,010 – 20) mg/l\ntrichlorometan (0,010 – 20) mg/l\nMetoda chromatografii gazowej z analiza fazy nadpowierzchniowej i detekcja plomieniowo-jonizacyjna (HS-GC-FID) PN-EN ISO 10301:2002","categories":["water"],"row_index":621,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of halogenated hydrocarbon derivatives","parameters_en":[{"name":"vinyl chloride","range":"(0,25 – 100) μg/l"},{"name":"Range","range":"1,2-dichloroetan (0,010 – 20) mg/l"},{"name":"tetrachloromethane","range":"(0,010 – 20) mg/l"},{"name":"tetrachloroethylene","range":"(0,010 – 20) mg/l"},{"name":"trichloroethylene","range":"(0,010 – 20) mg/l"},{"name":"trichloromethane","range":"(0,010 – 20) mg/l"}],"search_en":"Water, wastewater Concentration of halogenated hydrocarbon derivatives Headspace gas chromatography with flame ionization detection (HS-GC-FID) vinyl chloride Range tetrachloromethane tetrachloroethylene trichloroethylene trichloromethane PN-EN ISO 10301:2002","technique_en":"Headspace gas chromatography with flame ionization detection (HS-GC-FID)","test_object_en":"Water, wastewater","parameters_zh":[{"name":"氯乙烯","range":"(0,25 – 100) μg/l"},{"name":"范围","range":"1,2-dichloroetan (0,010 – 20) mg/l"},{"name":"四氯化碳","range":"(0,010 – 20) mg/l"},{"name":"四氯乙烯","range":"(0,010 – 20) mg/l"},{"name":"三氯乙烯","range":"(0,010 – 20) mg/l"},{"name":"三氯甲烷","range":"(0,010 – 20) mg/l"}],"search_zh":"水、废水 卤代烃浓度 顶空气相色谱-火焰离子化检测法（HS-GC-FID） 氯乙烯 范围 四氯化碳 四氯乙烯 三氯乙烯 三氯甲烷 PN-EN ISO 10301:2002","test_object_zh":"水、废水","technique_zh":"顶空气相色谱-火焰离子化检测法（HS-GC-FID）","methodology_zh":"卤代烃浓度"},{"_id":"6a836fb9af14b9c0e7b1ed85","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie fluorków","parameters":[{"name":"Zakres","range":"(0,050 – 100) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie fluorków\nZakres (0,050 – 100) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie fluorków\nZakres (0,050 – 100) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Woda, scieki Stezenie fluorkow\nZakres (0,050 – 100) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":622,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fluoride concentration","parameters_en":[{"name":"Range","range":"(0,050 – 100) mg/l"}],"search_en":"Water, wastewater Fluoride concentration Ion chromatography with conductometric detection (IC-CD) Range PN-EN ISO 10304-1:2009+AC:2012","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,050 – 100) mg/l"}],"search_zh":"水、废水 氟化物浓度 离子色谱-电导检测法（IC-CD） 范围 PN-EN ISO 10304-1:2009+AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水、废水","methodology_zh":"氟化物浓度"},{"_id":"6a836fb9af14b9c0e7b1ed86","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie cyjanków ogólnych, wolnych i związanych","parameters":[{"name":"Zakres","range":"(0,010 – 0,30) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie cyjanków ogólnych, wolnych i związanych\nZakres (0,010 – 0,30) mg/l\nMetoda spektrofotometryczna","reference":"Metoda nr 193 Wydanie 1 z dnia 26.09.2019 Test Spectroquant 1.14561.0001","norm_bases":["Metoda nr 193 Wydanie 1 z dnia 26.09.2019 Test Spectroquant 1.14561.0001"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie cyjanków ogólnych, wolnych i związanych\nZakres (0,010 – 0,30) mg/l\nMetoda spektrofotometryczna Metoda nr 193 Wydanie 1 z dnia 26.09.2019 Test Spectroquant 1.14561.0001 Woda, scieki Stezenie cyjankow ogolnych, wolnych i zwiazanych\nZakres (0,010 – 0,30) mg/l\nMetoda spektrofotometryczna Metoda nr 193 Wydanie 1 z dnia 26.09.2019 Test Spectroquant 1.14561.0001","categories":["water"],"row_index":623,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of total, free and bound cyanides","parameters_en":[{"name":"Range","range":"(0,010 – 0,30) mg/l"}],"search_en":"Water, wastewater Concentration of total, free and bound cyanides Spectrophotometric method Range Metoda nr 193 Wydanie 1 z dnia 26.09.2019 Test Spectroquant 1.14561.0001","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,010 – 0,30) mg/l"}],"search_zh":"水、废水 分光光度法 范围 Metoda nr 193 Wydanie 1 z dnia 26.09.2019 Test Spectroquant 1.14561.0001","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a836fb9af14b9c0e7b1ed87","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Cyjanki związane (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cyjanki związane (z obliczeń)","reference":"Metoda nr 193 Wydanie 1 z dnia 26.09.2019 Test Spectroquant 1.14561.0001","norm_bases":["Metoda nr 193 Wydanie 1 z dnia 26.09.2019 Test Spectroquant 1.14561.0001"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Cyjanki związane (z obliczeń) Metoda nr 193 Wydanie 1 z dnia 26.09.2019 Test Spectroquant 1.14561.0001 Woda, scieki Cyjanki zwiazane (z obliczen) Metoda nr 193 Wydanie 1 z dnia 26.09.2019 Test Spectroquant 1.14561.0001","categories":["water"],"row_index":624,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Bound cyanides (calculated)","search_en":"Water, wastewater Bound cyanides (calculated) Metoda nr 193 Wydanie 1 z dnia 26.09.2019 Test Spectroquant 1.14561.0001","test_object_en":"Water, wastewater","search_zh":"水、废水 Metoda nr 193 Wydanie 1 z dnia 26.09.2019 Test Spectroquant 1.14561.0001","test_object_zh":"水、废水"},{"_id":"6a836fb9af14b9c0e7b1ed88","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie pierwiastków","parameters":[{"name":"kadm","range":"(0,00200 – 10,0) mg/l"},{"name":"chrom ogólny","range":"(0,00200 – 10,0) mg/l"},{"name":"miedź","range":"(0,00200 – 10,0) mg/l"},{"name":"nikiel","range":"(0,00500 – 10,0) mg/l"},{"name":"ołów","range":"(0,0100 – 50,0) mg/l"},{"name":"cynk","range":"(0,00500 – 50,0) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie pierwiastków\nZakres:\nkadm (0,00200 – 10,0) mg/l\nchrom ogólny (0,00200 – 10,0) mg/l\nmiedź (0,00200 – 10,0) mg/l\nnikiel (0,00500 – 10,0) mg/l\nołów (0,0100 – 50,0) mg/l\ncynk (0,00500 – 50,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie pierwiastków\nZakres:\nkadm (0,00200 – 10,0) mg/l\nchrom ogólny (0,00200 – 10,0) mg/l\nmiedź (0,00200 – 10,0) mg/l\nnikiel (0,00500 – 10,0) mg/l\nołów (0,0100 – 50,0) mg/l\ncynk (0,00500 – 50,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Woda, scieki Stezenie pierwiastkow\nZakres:\nkadm (0,00200 – 10,0) mg/l\nchrom ogolny (0,00200 – 10,0) mg/l\nmiedz (0,00200 – 10,0) mg/l\nnikiel (0,00500 – 10,0) mg/l\nolow (0,0100 – 50,0) mg/l\ncynk (0,00500 – 50,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["water","materials"],"row_index":625,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element concentration","parameters_en":[{"name":"cadmium","range":"(0,00200 – 10,0) mg/l"},{"name":"total chromium","range":"(0,00200 – 10,0) mg/l"},{"name":"copper","range":"(0,00200 – 10,0) mg/l"},{"name":"nickel","range":"(0,00500 – 10,0) mg/l"},{"name":"lead","range":"(0,0100 – 50,0) mg/l"},{"name":"zinc","range":"(0,00500 – 50,0) mg/l"}],"search_en":"Water, wastewater Element concentration Inductively coupled plasma optical emission spectrometry (ICP-OES) cadmium total chromium copper nickel lead zinc PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Water, wastewater","methodology_zh":"元素浓度","parameters_zh":[{"name":"镉","range":"(0,00200 – 10,0) mg/l"},{"name":"总铬","range":"(0,00200 – 10,0) mg/l"},{"name":"铜","range":"(0,00200 – 10,0) mg/l"},{"name":"镍","range":"(0,00500 – 10,0) mg/l"},{"name":"铅","range":"(0,0100 – 50,0) mg/l"},{"name":"锌","range":"(0,00500 – 50,0) mg/l"}],"search_zh":"水、废水 元素浓度 电感耦合等离子体原子发射光谱法（ICP-OES） 镉 总铬 铜 镍 铅 锌 PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"水、废水"},{"_id":"6a836fb9af14b9c0e7b1ed89","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie pierwiastków","parameters":[{"name":"kobalt","range":"(0,00500 – 10,0) mg/l"},{"name":"żelazo","range":"(0,0200 – 50,0) mg/l"},{"name":"mangan","range":"(0,00200 – 50,0) mg/l"},{"name":"wanad","range":"(0,0200 – 10,0) mg/l"},{"name":"bar","range":"(0,00200 – 10,0) mg/l"},{"name":"bor","range":"(0,0100 – 1,00) mg/l"},{"name":"sód","range":"(0,500 – 2000) mg/l"},{"name":"molibden","range":"(0,00800 – 10,0) mg/l"},{"name":"wapń","range":"(0,200 – 1000) mg/l"},{"name":"magnez","range":"(0,100 – 1000) mg/l"},{"name":"potas","range":"(0,100 – 1000) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie pierwiastków\nZakres:\nkobalt (0,00500 – 10,0) mg/l\nżelazo (0,0200 – 50,0) mg/l\nmangan (0,00200 – 50,0) mg/l\nwanad (0,0200 – 10,0) mg/l\nbar (0,00200 – 10,0) mg/l\nbor (0,0100 – 1,00) mg/l\nsód (0,500 – 2000) mg/l\nmolibden (0,00800 – 10,0) mg/l\nwapń (0,200 – 1000) mg/l\nmagnez (0,100 – 1000) mg/l\npotas (0,100 – 1000) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie pierwiastków\nZakres:\nkobalt (0,00500 – 10,0) mg/l\nżelazo (0,0200 – 50,0) mg/l\nmangan (0,00200 – 50,0) mg/l\nwanad (0,0200 – 10,0) mg/l\nbar (0,00200 – 10,0) mg/l\nbor (0,0100 – 1,00) mg/l\nsód (0,500 – 2000) mg/l\nmolibden (0,00800 – 10,0) mg/l\nwapń (0,200 – 1000) mg/l\nmagnez (0,100 – 1000) mg/l\npotas (0,100 – 1000) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Woda, scieki Stezenie pierwiastkow\nZakres:\nkobalt (0,00500 – 10,0) mg/l\nzelazo (0,0200 – 50,0) mg/l\nmangan (0,00200 – 50,0) mg/l\nwanad (0,0200 – 10,0) mg/l\nbar (0,00200 – 10,0) mg/l\nbor (0,0100 – 1,00) mg/l\nsod (0,500 – 2000) mg/l\nmolibden (0,00800 – 10,0) mg/l\nwapn (0,200 – 1000) mg/l\nmagnez (0,100 – 1000) mg/l\npotas (0,100 – 1000) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["water"],"row_index":626,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element concentration","parameters_en":[{"name":"cobalt","range":"(0,00500 – 10,0) mg/l"},{"name":"iron","range":"(0,0200 – 50,0) mg/l"},{"name":"manganese","range":"(0,00200 – 50,0) mg/l"},{"name":"vanadium","range":"(0,0200 – 10,0) mg/l"},{"name":"barium","range":"(0,00200 – 10,0) mg/l"},{"name":"boron","range":"(0,0100 – 1,00) mg/l"},{"name":"sodium","range":"(0,500 – 2000) mg/l"},{"name":"molybdenum","range":"(0,00800 – 10,0) mg/l"},{"name":"calcium","range":"(0,200 – 1000) mg/l"},{"name":"magnesium","range":"(0,100 – 1000) mg/l"},{"name":"potassium","range":"(0,100 – 1000) mg/l"}],"search_en":"Water, wastewater Element concentration Inductively coupled plasma optical emission spectrometry (ICP-OES) cobalt iron manganese vanadium barium boron sodium molybdenum calcium magnesium potassium PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Water, wastewater","methodology_zh":"元素浓度","search_zh":"水、废水 元素浓度 电感耦合等离子体原子发射光谱法（ICP-OES） 钴 铁 锰 钒 钡 硼 钠 钼 钙 镁 钾 PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"水、废水","parameters_zh":[{"name":"钴","range":"(0,00500 – 10,0) mg/l"},{"name":"铁","range":"(0,0200 – 50,0) mg/l"},{"name":"锰","range":"(0,00200 – 50,0) mg/l"},{"name":"钒","range":"(0,0200 – 10,0) mg/l"},{"name":"钡","range":"(0,00200 – 10,0) mg/l"},{"name":"硼","range":"(0,0100 – 1,00) mg/l"},{"name":"钠","range":"(0,500 – 2000) mg/l"},{"name":"钼","range":"(0,00800 – 10,0) mg/l"},{"name":"钙","range":"(0,200 – 1000) mg/l"},{"name":"镁","range":"(0,100 – 1000) mg/l"},{"name":"钾","range":"(0,100 – 1000) mg/l"}]},{"_id":"6a836fb9af14b9c0e7b1ed8a","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie pierwiastków","parameters":[{"name":"arsen","range":"(0,0200 – 1,00) mg/l"},{"name":"antymon","range":"(0,0200 – 1,00) mg/l"},{"name":"selen","range":"(0,0100 – 1,00) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES)"],"computed":[],"activity":"Stężenie pierwiastków\nZakres:\narsen (0,0200 – 1,00) mg/l\nantymon (0,0200 – 1,00) mg/l\nselen (0,0100 – 1,00) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie pierwiastków\nZakres:\narsen (0,0200 – 1,00) mg/l\nantymon (0,0200 – 1,00) mg/l\nselen (0,0100 – 1,00) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES) PN-EN ISO 11885:2009 Woda, scieki Stezenie pierwiastkow\nZakres:\narsen (0,0200 – 1,00) mg/l\nantymon (0,0200 – 1,00) mg/l\nselen (0,0100 – 1,00) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej z generowaniem wodorkow (HG-ICP-OES) PN-EN ISO 11885:2009","categories":["water"],"row_index":627,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element concentration","parameters_en":[{"name":"arsenic","range":"(0,0200 – 1,00) mg/l"},{"name":"antimony","range":"(0,0200 – 1,00) mg/l"},{"name":"selenium","range":"(0,0100 – 1,00) mg/l"}],"search_en":"Water, wastewater Element concentration Hydride generation inductively coupled plasma optical emission spectrometry (HG-ICP-OES) arsenic antimony selenium PN-EN ISO 11885:2009","technique_en":"Hydride generation inductively coupled plasma optical emission spectrometry (HG-ICP-OES)","test_object_en":"Water, wastewater","methodology_zh":"元素浓度","search_zh":"水、废水 元素浓度 氢化物发生电感耦合等离子体发射光谱法（HG-ICP-OES） 砷 锑 硒 PN-EN ISO 11885:2009","test_object_zh":"水、废水","parameters_zh":[{"name":"砷","range":"(0,0200 – 1,00) mg/l"},{"name":"锑","range":"(0,0200 – 1,00) mg/l"},{"name":"硒","range":"(0,0100 – 1,00) mg/l"}],"technique_zh":"氢化物发生电感耦合等离子体发射光谱法（HG-ICP-OES）"},{"_id":"6a836fb9af14b9c0e7b1ed8b","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie rtęci","parameters":[{"name":"Zakres","range":"(0,20 – 70) μg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","techniques":["Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji"],"computed":[],"activity":"Stężenie rtęci\nZakres (0,20 – 70) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","reference":"Metoda nr 194 Wydanie 1 z dnia 26.09.2019","norm_bases":["Metoda nr 194 Wydanie 1 z dnia 26.09.2019"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie rtęci\nZakres (0,20 – 70) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji Metoda nr 194 Wydanie 1 z dnia 26.09.2019 Woda, scieki Stezenie rteci\nZakres (0,20 – 70) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z technika amalgamacji Metoda nr 194 Wydanie 1 z dnia 26.09.2019","categories":["water"],"row_index":628,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury concentration","parameters_en":[{"name":"Range","range":"(0,20 – 70) μg/l"}],"search_en":"Water, wastewater Mercury concentration Atomic absorption spectrometry with amalgamation technique Range Metoda nr 194 Wydanie 1 z dnia 26.09.2019","technique_en":"Atomic absorption spectrometry with amalgamation technique","test_object_en":"Water, wastewater","methodology_zh":"汞浓度","parameters_zh":[{"name":"范围","range":"(0,20 – 70) μg/l"}],"search_zh":"水、废水 汞浓度 原子吸收光谱法（汞齐化技术） 范围 Metoda nr 194 Wydanie 1 z dnia 26.09.2019","technique_zh":"原子吸收光谱法（汞齐化技术）","test_object_zh":"水、废水"},{"_id":"6a836fb9af14b9c0e7b1ed8c","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Steżenie węglowodorów C6-C12","parameters":[{"name":"Zakres","range":"(0,020 - 1000) mg/l"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Steżenie węglowodorów C6-C12\nZakres (0,020 - 1000) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-C-04643:1994","norm_bases":["PN-C-04643:1994"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Steżenie węglowodorów C6-C12\nZakres (0,020 - 1000) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-C-04643:1994 Woda, scieki Stezenie weglowodorow C6-C12\nZakres (0,020 - 1000) mg/l\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-C-04643:1994","categories":["water"],"row_index":629,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of C6-C12 hydrocarbons","parameters_en":[{"name":"Range","range":"(0,020 - 1000) mg/l"}],"search_en":"Water, wastewater Concentration of C6-C12 hydrocarbons Gas chromatography with flame ionization detection (GC-FID) Range PN-C-04643:1994","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,020 - 1000) mg/l"}],"search_zh":"水、废水 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-C-04643:1994","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"水、废水"},{"_id":"6a836fb9af14b9c0e7b1ed8d","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Steżenie węglowodorów C12-C35","parameters":[{"name":"Zakres","range":"(0,50 – 5000) mg/l"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Steżenie węglowodorów C12-C35\nZakres (0,50 – 5000) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-C-04643:1994","norm_bases":["PN-C-04643:1994"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Steżenie węglowodorów C12-C35\nZakres (0,50 – 5000) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-C-04643:1994 Woda, scieki Stezenie weglowodorow C12-C35\nZakres (0,50 – 5000) mg/l\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-C-04643:1994","categories":["water"],"row_index":630,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"C12-C35 hydrocarbon concentration","parameters_en":[{"name":"Range","range":"(0,50 – 5000) mg/l"}],"search_en":"Water, wastewater C12-C35 hydrocarbon concentration Gas chromatography with flame ionization detection (GC-FID) Range PN-C-04643:1994","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,50 – 5000) mg/l"}],"search_zh":"水、废水 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-C-04643:1994","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"水、废水"},{"_id":"6a836fb9af14b9c0e7b1ed8e","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Suma węglowodorów C6-C35 (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma węglowodorów C6-C35 (z obliczeń)","reference":"PN-C-04643:1994","norm_bases":["PN-C-04643:1994"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Suma węglowodorów C6-C35 (z obliczeń) PN-C-04643:1994 Woda, scieki Suma weglowodorow C6-C35 (z obliczen) PN-C-04643:1994","categories":["water"],"row_index":631,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of C6-C35 hydrocarbons (calculated)","search_en":"Water, wastewater Sum of C6-C35 hydrocarbons (calculated) PN-C-04643:1994","test_object_en":"Water, wastewater","search_zh":"水、废水 PN-C-04643:1994","test_object_zh":"水、废水"},{"_id":"6a836fb9af14b9c0e7b1ed8f","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Zasadowość wobec fenololoftaleiny","parameters":[{"name":"Zakres","range":"(0,40 – 20) mmol/l"},{"name":"Zasadowość ogólna"},{"name":"Zakres","range":"(0,40 – 20) mmol/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zasadowość wobec fenololoftaleiny\nZakres:\nZakres (0,40 – 20) mmol/l\nZasadowość ogólna\nZakres (0,40 – 20) mmol/l\nMetoda miareczkowa","reference":"PN-EN ISO 9963-1:2001+Ap1:2004","norm_bases":["PN-EN ISO 9963-1:2001+Ap1:2004"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Zasadowość wobec fenololoftaleiny\nZakres:\nZakres (0,40 – 20) mmol/l\nZasadowość ogólna\nZakres (0,40 – 20) mmol/l\nMetoda miareczkowa PN-EN ISO 9963-1:2001+Ap1:2004 Woda, scieki Zasadowosc wobec fenololoftaleiny\nZakres:\nZakres (0,40 – 20) mmol/l\nZasadowosc ogolna\nZakres (0,40 – 20) mmol/l\nMetoda miareczkowa PN-EN ISO 9963-1:2001+Ap1:2004","categories":["water"],"row_index":632,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Alkalinity to phenolphthalein","parameters_en":[{"name":"Range","range":"(0,40 – 20) mmol/l"},{"name":"Total alkalinity"},{"name":"Range","range":"(0,40 – 20) mmol/l"}],"search_en":"Water, wastewater Alkalinity to phenolphthalein Titrimetric method Range Total alkalinity Range PN-EN ISO 9963-1:2001+Ap1:2004","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,40 – 20) mmol/l"},{"name":"总碱度"},{"name":"范围","range":"(0,40 – 20) mmol/l"}],"search_zh":"水、废水 滴定法 范围 总碱度 范围 PN-EN ISO 9963-1:2001+Ap1:2004","technique_zh":"滴定法","test_object_zh":"水、废水"},{"_id":"6a836fb9af14b9c0e7b1ed90","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Wyroby chemiczne: oleje elektroizolacyjne","methodology":"Stężenie polichlorowanych bifenyli (PCB)","parameters":[{"name":"Aroclor 1242","range":"(5,0 – 50) mg/kg"},{"name":"Aroclor 1254","range":"(5,0 – 50) mg/kg"},{"name":"Aroclor 1260","range":"(5,0 – 50) mg/kg"}],"technique":"Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","techniques":["Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)"],"computed":[],"activity":"Stężenie polichlorowanych bifenyli (PCB)\nZakres:\nAroclor 1242 (5,0 – 50) mg/kg\nAroclor 1254 (5,0 – 50) mg/kg\nAroclor 1260 (5,0 – 50) mg/kg\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","reference":"PN-IEC 997:1998","norm_bases":["PN-IEC 997:1998"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby chemiczne: oleje elektroizolacyjne Stężenie polichlorowanych bifenyli (PCB)\nZakres:\nAroclor 1242 (5,0 – 50) mg/kg\nAroclor 1254 (5,0 – 50) mg/kg\nAroclor 1260 (5,0 – 50) mg/kg\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) PN-IEC 997:1998 Wyroby chemiczne: oleje elektroizolacyjne Stezenie polichlorowanych bifenyli (PCB)\nZakres:\nAroclor 1242 (5,0 – 50) mg/kg\nAroclor 1254 (5,0 – 50) mg/kg\nAroclor 1260 (5,0 – 50) mg/kg\nMetoda chromatografii gazowej z detekcja wychwytu elektronow (GC-ECD) PN-IEC 997:1998","categories":["petro"],"row_index":633,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Polychlorinated biphenyls (PCB) concentration","parameters_en":[{"name":"Aroclor 1242","range":"(5,0 – 50) mg/kg"},{"name":"Aroclor 1254","range":"(5,0 – 50) mg/kg"},{"name":"Aroclor 1260","range":"(5,0 – 50) mg/kg"}],"search_en":"Chemical products: electrical insulating oils Polychlorinated biphenyls (PCB) concentration Gas chromatography with electron capture detection (GC-ECD) Aroclor 1242 Aroclor 1254 Aroclor 1260 PN-IEC 997:1998","technique_en":"Gas chromatography with electron capture detection (GC-ECD)","test_object_en":"Chemical products: electrical insulating oils","search_zh":"化工产品：电绝缘油 多氯联苯（PCB）浓度 气相色谱-电子捕获检测法（GC-ECD） PN-IEC 997:1998","technique_zh":"气相色谱-电子捕获检测法（GC-ECD）","methodology_zh":"多氯联苯（PCB）浓度","test_object_zh":"化工产品：电绝缘油"},{"_id":"6a836fb9af14b9c0e7b1ed91","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko ogólne – próbki gazów odlotowych pobrane na rurki z sorbentem","methodology":"Zawartość związków organicznych","parameters":[{"name":"chlorek winylu"},{"name":"Zakres","range":"(0,050 – 250) μg w próbce"},{"name":"1,2-dichloroetan (0,10 – 250) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość związków organicznych\nZakres:\nchlorek winylu\nZakres (0,050 – 250) μg w próbce\n1,2-dichloroetan (0,10 – 250) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – próbki gazów odlotowych pobrane na rurki z sorbentem Zawartość związków organicznych\nZakres:\nchlorek winylu\nZakres (0,050 – 250) μg w próbce\n1,2-dichloroetan (0,10 – 250) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Srodowisko ogolne – probki gazow odlotowych pobrane na rurki z sorbentem Zawartosc zwiazkow organicznych\nZakres:\nchlorek winylu\nZakres (0,050 – 250) μg w probce\n1,2-dichloroetan (0,10 – 250) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["environment"],"row_index":634,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of organic compounds","parameters_en":[{"name":"vinyl chloride"},{"name":"Range","range":"(0,050 – 250) μg w próbce"},{"name":"1,2-dichloroetan (0,10 – 250) μg w próbce"}],"search_en":"General environment – waste gas samples collected on sorbent tubes Content of organic compounds Gas chromatography with flame ionization detection (GC-FID) vinyl chloride Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"General environment – waste gas samples collected on sorbent tubes","parameters_zh":[{"name":"氯乙烯"},{"name":"范围","range":"(0,050 – 250) μg w próbce"},{"name":"1,2-dichloroetan (0,10 – 250) μg w próbce"}],"search_zh":"一般环境 — 用吸附管采集的废气样品 有机化合物含量 气相色谱-氢火焰离子化检测法（GC-FID） 氯乙烯 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"一般环境 — 用吸附管采集的废气样品","methodology_zh":"有机化合物含量"},{"_id":"6a836fb9af14b9c0e7b1ed92","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko ogólne – próbki gazów odlotowych pobrane na rurki z sorbentem","methodology":"Zawartość trichlorometanu","parameters":[{"name":"Zakres","range":"(1,0 – 250) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość trichlorometanu\nZakres (1,0 – 250) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – próbki gazów odlotowych pobrane na rurki z sorbentem Zawartość trichlorometanu\nZakres (1,0 – 250) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Srodowisko ogolne – probki gazow odlotowych pobrane na rurki z sorbentem Zawartosc trichlorometanu\nZakres (1,0 – 250) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["environment"],"row_index":635,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Trichloromethane content","parameters_en":[{"name":"Range","range":"(1,0 – 250) μg w próbce"}],"search_en":"General environment – waste gas samples collected on sorbent tubes Trichloromethane content Gas chromatography with flame ionization detection (GC-FID) Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"General environment – waste gas samples collected on sorbent tubes","parameters_zh":[{"name":"范围","range":"(1,0 – 250) μg w próbce"}],"search_zh":"一般环境 — 用吸附管采集的废气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"一般环境 — 用吸附管采集的废气样品"},{"_id":"6a836fb9af14b9c0e7b1ed93","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko ogólne – próbki gazów odlotowych pobrane na rurki z sorbentem","methodology":"Zawartość sumy węglowodorów aromatycznych: benzen, etylobenzen, styren, toluen, o-ksylen, (m+p)ksyleny (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość sumy węglowodorów aromatycznych: benzen, etylobenzen, styren, toluen, o-ksylen, (m+p)ksyleny (z obliczeń)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – próbki gazów odlotowych pobrane na rurki z sorbentem Zawartość sumy węglowodorów aromatycznych: benzen, etylobenzen, styren, toluen, o-ksylen, (m+p)ksyleny (z obliczeń) PN-EN 13649:2005 Srodowisko ogolne – probki gazow odlotowych pobrane na rurki z sorbentem Zawartosc sumy weglowodorow aromatycznych: benzen, etylobenzen, styren, toluen, o-ksylen, (m+p)ksyleny (z obliczen) PN-EN 13649:2005","categories":["environment"],"row_index":636,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of the sum of aromatic hydrocarbons: benzene, ethylbenzene, styrene, toluene, o-xylene, (m+p)xylenes (calculated)","search_en":"General environment – waste gas samples collected on sorbent tubes Content of the sum of aromatic hydrocarbons: benzene, ethylbenzene, styrene, toluene, o-xylene, (m+p)xylenes (calculated) PN-EN 13649:2005","test_object_en":"General environment – waste gas samples collected on sorbent tubes","search_zh":"一般环境 — 用吸附管采集的废气样品 PN-EN 13649:2005","test_object_zh":"一般环境 — 用吸附管采集的废气样品"},{"_id":"6a836fb9af14b9c0e7b1ed94","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko ogólne – próbki gazów odlotowych pobrane na rurki z sorbentem","methodology":"Zawartość związków organicznych węglowodory alifatyczne C5 – C12","parameters":[{"name":"Zakres","range":"(1,0 – 500) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość związków organicznych węglowodory alifatyczne C5 – C12\nZakres (1,0 – 500) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – próbki gazów odlotowych pobrane na rurki z sorbentem Zawartość związków organicznych węglowodory alifatyczne C5 – C12\nZakres (1,0 – 500) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Srodowisko ogolne – probki gazow odlotowych pobrane na rurki z sorbentem Zawartosc zwiazkow organicznych weglowodory alifatyczne C5 – C12\nZakres (1,0 – 500) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["environment"],"row_index":637,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of organic compounds aliphatic hydrocarbons C5 – C12","parameters_en":[{"name":"Range","range":"(1,0 – 500) μg w próbce"}],"search_en":"General environment – waste gas samples collected on sorbent tubes Content of organic compounds aliphatic hydrocarbons C5 – C12 Gas chromatography with flame ionization detection (GC-FID) Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"General environment – waste gas samples collected on sorbent tubes","parameters_zh":[{"name":"范围","range":"(1,0 – 500) μg w próbce"}],"search_zh":"一般环境 — 用吸附管采集的废气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"一般环境 — 用吸附管采集的废气样品"},{"_id":"6a836fb9af14b9c0e7b1ed95","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko ogólne – próbki gazów odlotowych pobrane na rurki z sorbentem","methodology":"Zawartość metanolu","parameters":[{"name":"Zakres","range":"(5,0 – 100) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość metanolu\nZakres (5,0 – 100) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – próbki gazów odlotowych pobrane na rurki z sorbentem Zawartość metanolu\nZakres (5,0 – 100) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Srodowisko ogolne – probki gazow odlotowych pobrane na rurki z sorbentem Zawartosc metanolu\nZakres (5,0 – 100) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["environment"],"row_index":638,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Methanol content","parameters_en":[{"name":"Range","range":"(5,0 – 100) μg w próbce"}],"search_en":"General environment – waste gas samples collected on sorbent tubes Methanol content Gas chromatography with flame ionization detection (GC-FID) Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"General environment – waste gas samples collected on sorbent tubes","parameters_zh":[{"name":"范围","range":"(5,0 – 100) μg w próbce"}],"search_zh":"一般环境 — 用吸附管采集的废气样品 甲醇含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"一般环境 — 用吸附管采集的废气样品","methodology_zh":"甲醇含量"},{"_id":"6a836fb9af14b9c0e7b1ed96","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko ogólne – próbki gazów odlotowych pobrane na rurki z sorbentem","methodology":"Zawartość związków organicznych","parameters":[{"name":"o-ksylen (1,0 – 2 500) μg w próbce (m+p)-ksylen (1,0 – 5000) μg w próbce toluen (1,0 – 2 500) μg w próbce styren (1,0 – 2 500) μg w próbce metyloetyloketon"},{"name":"Zakres","range":"(1,0 – 2 500) μg w próbce"},{"name":"octan metylu (1,0 – 2 500) μg w próbce etylobenzen (1,0 – 2 500) μg w próbce benzen (1,0 – 2 500) μg w próbce (o+m+p)-ksylen (1,0 – 7 500) μg w próbce tetrachloroetylen (1,0 – 3 000) μg w próbce bromometan (5,0 – 2 500) μg w próbce trichloroeten (1,0 – 500) μg w próbce 1,1 dichloroeten (1,0 – 500) μg w próbce 1,2 dichloroeten (1,0 – 500) μg w próbce 1,1,2 trichloroetan (1,0 – 500) μg w próbce tetrachlorometan (1,0 – 500) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość związków organicznych\nZakres:\no-ksylen (1,0 – 2 500) μg w próbce (m+p)-ksylen (1,0 – 5000) μg w próbce toluen (1,0 – 2 500) μg w próbce styren (1,0 – 2 500) μg w próbce metyloetyloketon\nZakres (1,0 – 2 500) μg w próbce\noctan metylu (1,0 – 2 500) μg w próbce etylobenzen (1,0 – 2 500) μg w próbce benzen (1,0 – 2 500) μg w próbce (o+m+p)-ksylen (1,0 – 7 500) μg w próbce tetrachloroetylen (1,0 – 3 000) μg w próbce bromometan (5,0 – 2 500) μg w próbce trichloroeten (1,0 – 500) μg w próbce 1,1 dichloroeten (1,0 – 500) μg w próbce 1,2 dichloroeten (1,0 – 500) μg w próbce 1,1,2 trichloroetan (1,0 – 500) μg w próbce tetrachlorometan (1,0 – 500) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – próbki gazów odlotowych pobrane na rurki z sorbentem Zawartość związków organicznych\nZakres:\no-ksylen (1,0 – 2 500) μg w próbce (m+p)-ksylen (1,0 – 5000) μg w próbce toluen (1,0 – 2 500) μg w próbce styren (1,0 – 2 500) μg w próbce metyloetyloketon\nZakres (1,0 – 2 500) μg w próbce\noctan metylu (1,0 – 2 500) μg w próbce etylobenzen (1,0 – 2 500) μg w próbce benzen (1,0 – 2 500) μg w próbce (o+m+p)-ksylen (1,0 – 7 500) μg w próbce tetrachloroetylen (1,0 – 3 000) μg w próbce bromometan (5,0 – 2 500) μg w próbce trichloroeten (1,0 – 500) μg w próbce 1,1 dichloroeten (1,0 – 500) μg w próbce 1,2 dichloroeten (1,0 – 500) μg w próbce 1,1,2 trichloroetan (1,0 – 500) μg w próbce tetrachlorometan (1,0 – 500) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Srodowisko ogolne – probki gazow odlotowych pobrane na rurki z sorbentem Zawartosc zwiazkow organicznych\nZakres:\no-ksylen (1,0 – 2 500) μg w probce (m+p)-ksylen (1,0 – 5000) μg w probce toluen (1,0 – 2 500) μg w probce styren (1,0 – 2 500) μg w probce metyloetyloketon\nZakres (1,0 – 2 500) μg w probce\noctan metylu (1,0 – 2 500) μg w probce etylobenzen (1,0 – 2 500) μg w probce benzen (1,0 – 2 500) μg w probce (o+m+p)-ksylen (1,0 – 7 500) μg w probce tetrachloroetylen (1,0 – 3 000) μg w probce bromometan (5,0 – 2 500) μg w probce trichloroeten (1,0 – 500) μg w probce 1,1 dichloroeten (1,0 – 500) μg w probce 1,2 dichloroeten (1,0 – 500) μg w probce 1,1,2 trichloroetan (1,0 – 500) μg w probce tetrachlorometan (1,0 – 500) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["environment"],"row_index":639,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of organic compounds","parameters_en":[{"name":"o-xylene (1,0 – 2 500) μg in sample (m+p)-xylene (1,0 – 5000) μg in sample toluene (1,0 – 2 500) μg in sample styrene (1,0 – 2 500) μg in sample methyl ethyl ketone"},{"name":"Range","range":"(1,0 – 2 500) μg w próbce"},{"name":"methyl acetate (1,0 – 2 500) μg in sample ethylbenzene (1,0 – 2 500) μg in sample benzene (1,0 – 2 500) μg in sample (o+m+p)-xylene (1,0 – 7 500) μg in sample tetrachloroethylene (1,0 – 3 000) μg in sample bromomethane (5,0 – 2 500) μg in sample trichloroethene (1,0 – 500) μg in sample 1,1 dichloroethene (1,0 – 500) μg in sample 1,2 dichloroethene (1,0 – 500) μg in sample 1,1,2 trichloroethane (1,0 – 500) μg in sample tetrachloromethane (1,0 – 500) μg in sample"}],"search_en":"General environment – waste gas samples collected on sorbent tubes Content of organic compounds Gas chromatography with flame ionization detection (GC-FID) o-xylene (1,0 – 2 500) μg in sample (m+p)-xylene (1,0 – 5000) μg in sample toluene (1,0 – 2 500) μg in sample styrene (1,0 – 2 500) μg in sample methyl ethyl ketone Range methyl acetate (1,0 – 2 500) μg in sample ethylbenzene (1,0 – 2 500) μg in sample benzene (1,0 – 2 500) μg in sample (o+m+p)-xylene (1,0 – 7 500) μg in sample tetrachloroethylene (1,0 – 3 000) μg in sample bromomethane (5,0 – 2 500) μg in sample trichloroethene (1,0 – 500) μg in sample 1,1 dichloroethene (1,0 – 500) μg in sample 1,2 dichloroethene (1,0 – 500) μg in sample 1,1,2 trichloroethane (1,0 – 500) μg in sample tetrachloromethane (1,0 – 500) μg in sample PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"General environment – waste gas samples collected on sorbent tubes","parameters_zh":[{"name":"o-ksylen (1,0 – 2 500) μg w próbce (m+p)-ksylen (1,0 – 5000) μg w próbce toluen (1,0 – 2 500) μg w próbce styren (1,0 – 2 500) μg w próbce metyloetyloketon"},{"name":"范围","range":"(1,0 – 2 500) μg w próbce"},{"name":"octan metylu (1,0 – 2 500) μg w próbce etylobenzen (1,0 – 2 500) μg w próbce benzen (1,0 – 2 500) μg w próbce (o+m+p)-ksylen (1,0 – 7 500) μg w próbce tetrachloroetylen (1,0 – 3 000) μg w próbce bromometan (5,0 – 2 500) μg w próbce trichloroeten (1,0 – 500) μg w próbce 1,1 dichloroeten (1,0 – 500) μg w próbce 1,2 dichloroeten (1,0 – 500) μg w próbce 1,1,2 trichloroetan (1,0 – 500) μg w próbce tetrachlorometan (1,0 – 500) μg w próbce"}],"search_zh":"一般环境 — 用吸附管采集的废气样品 有机化合物含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"一般环境 — 用吸附管采集的废气样品","methodology_zh":"有机化合物含量"},{"_id":"6a836fb9af14b9c0e7b1ed97","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko ogólne – próbki gazów odlotowych pobrane na rurki z sorbentem","methodology":"Zawartość glikolu etylenowego","parameters":[{"name":"Zakres","range":"(100 – 2500) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość glikolu etylenowego\nZakres (100 – 2500) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – próbki gazów odlotowych pobrane na rurki z sorbentem Zawartość glikolu etylenowego\nZakres (100 – 2500) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Srodowisko ogolne – probki gazow odlotowych pobrane na rurki z sorbentem Zawartosc glikolu etylenowego\nZakres (100 – 2500) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["environment"],"row_index":640,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ethylene glycol content","parameters_en":[{"name":"Range","range":"(100 – 2500) μg w próbce"}],"search_en":"General environment – waste gas samples collected on sorbent tubes Ethylene glycol content Gas chromatography with flame ionization detection (GC-FID) Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"General environment – waste gas samples collected on sorbent tubes","parameters_zh":[{"name":"范围","range":"(100 – 2500) μg w próbce"}],"search_zh":"一般环境 — 用吸附管采集的废气样品 乙二醇含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"一般环境 — 用吸附管采集的废气样品","methodology_zh":"乙二醇含量"},{"_id":"6a836fb9af14b9c0e7b1ed98","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko pracy – próbki powietrza pobrane na filtry","methodology":"Zawartość kwasu siarkowego - frakcja torakalna","parameters":[{"name":"Zakres","range":"(0,0026 – 0,10) mg w próbce"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną"],"computed":[],"activity":"Zawartość kwasu siarkowego - frakcja torakalna\nZakres (0,0026 – 0,10) mg w próbce\nMetoda chromatografii jonowej z detekcją konduktometryczną","reference":"Podstawy Metody Oceny Środowiska Pracy 2012 nr 1(71) + 2017 nr 2 (92)","norm_bases":["Podstawy Metody Oceny Środowiska Pracy 2012 nr 1(71) + 2017 nr 2 (92)"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – próbki powietrza pobrane na filtry Zawartość kwasu siarkowego - frakcja torakalna\nZakres (0,0026 – 0,10) mg w próbce\nMetoda chromatografii jonowej z detekcją konduktometryczną Podstawy Metody Oceny Środowiska Pracy 2012 nr 1(71) + 2017 nr 2 (92) Srodowisko pracy – probki powietrza pobrane na filtry Zawartosc kwasu siarkowego - frakcja torakalna\nZakres (0,0026 – 0,10) mg w probce\nMetoda chromatografii jonowej z detekcja konduktometryczna Podstawy Metody Oceny Srodowiska Pracy 2012 nr 1(71) + 2017 nr 2 (92)","categories":["environment"],"row_index":641,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulphuric acid content - thoracic fraction","parameters_en":[{"name":"Range","range":"(0,0026 – 0,10) mg w próbce"}],"search_en":"Workplace environment – air samples collected on filters Sulphuric acid content - thoracic fraction Ion chromatography with conductometric detection Range Podstawy Metody Oceny Środowiska Pracy 2012 nr 1(71) + 2017 nr 2 (92)","technique_en":"Ion chromatography with conductometric detection","test_object_en":"Workplace environment – air samples collected on filters","parameters_zh":[{"name":"范围","range":"(0,0026 – 0,10) mg w próbce"}],"search_zh":"工作场所环境 — 用滤膜采集的空气样品 离子色谱-电导检测法 范围 Podstawy Metody Oceny Środowiska Pracy 2012 nr 1(71) + 2017 nr 2 (92)","test_object_zh":"工作场所环境 — 用滤膜采集的空气样品","technique_zh":"离子色谱-电导检测法"},{"_id":"6a836fb9af14b9c0e7b1ed99","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko ogólne – próbki gazów odlotowych pobrane na filtry","methodology":"Zawartość arsenu i antymonu","parameters":[{"name":"As","range":"(0,000500 – 0,05000) mg w"},{"name":"próbce"},{"name":"Sb","range":"(0,00100 – 0,0500) mg w próbce"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES)"],"computed":[],"activity":"Zawartość arsenu i antymonu\nZakres:\nAs (0,000500 – 0,05000) mg w\npróbce\nSb (0,00100 – 0,0500) mg w próbce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES)","reference":"PN-EN 14385:2025:05","norm_bases":["PN-EN 14385:2025:05"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – próbki gazów odlotowych pobrane na filtry Zawartość arsenu i antymonu\nZakres:\nAs (0,000500 – 0,05000) mg w\npróbce\nSb (0,00100 – 0,0500) mg w próbce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES) PN-EN 14385:2025:05 Srodowisko ogolne – probki gazow odlotowych pobrane na filtry Zawartosc arsenu i antymonu\nZakres:\nAs (0,000500 – 0,05000) mg w\nprobce\nSb (0,00100 – 0,0500) mg w probce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej z generowaniem wodorkow (HG-ICP-OES) PN-EN 14385:2025:05","categories":["environment"],"row_index":642,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Arsenic and antimony content","parameters_en":[{"name":"As","range":"(0,000500 – 0,05000) mg w"},{"name":"sample"},{"name":"Sb","range":"(0,00100 – 0,0500) mg w próbce"}],"search_en":"General environment – waste gas samples collected on filters Arsenic and antimony content Hydride generation inductively coupled plasma optical emission spectrometry (HG-ICP-OES) As sample Sb PN-EN 14385:2025:05","technique_en":"Hydride generation inductively coupled plasma optical emission spectrometry (HG-ICP-OES)","test_object_en":"General environment – waste gas samples collected on filters","parameters_zh":[{"name":"As","range":"(0,000500 – 0,05000) mg w"},{"name":"样品中"},{"name":"Sb","range":"(0,00100 – 0,0500) mg w próbce"}],"search_zh":"一般环境 — 用滤膜采集的废气样品 氢化物发生电感耦合等离子体发射光谱法（HG-ICP-OES） As 样品中 Sb PN-EN 14385:2025:05","technique_zh":"氢化物发生电感耦合等离子体发射光谱法（HG-ICP-OES）","test_object_zh":"一般环境 — 用滤膜采集的废气样品"},{"_id":"6a836fb9af14b9c0e7b1ed9a","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko ogólne – próbki gazów odlotowych pobrane na filtry","methodology":"Zawartość pierwiastków:","parameters":[{"name":"Cd","range":"(0,000250 – 0,500) mg w próbce"},{"name":"Cr","range":"(0,000250 – 0,500) mg w próbce"},{"name":"Co","range":"(0,000250 – 0,500) mg w próbce"},{"name":"Cu","range":"(0,000250 – 0,500) mg w próbce"},{"name":"Mn","range":"(0,000250 – 0,500) mg w próbce"},{"name":"Ni","range":"(0,000500 – 0,500) mg w próbce"},{"name":"Pb","range":"(0,00250 – 2,50) mg w próbce"},{"name":"Tl","range":"(0,000500 – 0,0500) mg w próbce"},{"name":"V","range":"(0,00250 – 0,0500) mg w próbce"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość pierwiastków:\nZakres:\nCd (0,000250 – 0,500) mg w próbce\nCr (0,000250 – 0,500) mg w próbce\nCo (0,000250 – 0,500) mg w próbce\nCu (0,000250 – 0,500) mg w próbce\nMn (0,000250 – 0,500) mg w próbce\nNi (0,000500 – 0,500) mg w próbce\nPb (0,00250 – 2,50) mg w próbce\nTl (0,000500 – 0,0500) mg w próbce\nV (0,00250 – 0,0500) mg w próbce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN 14385:2025:05","norm_bases":["PN-EN 14385:2025:05"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – próbki gazów odlotowych pobrane na filtry Zawartość pierwiastków:\nZakres:\nCd (0,000250 – 0,500) mg w próbce\nCr (0,000250 – 0,500) mg w próbce\nCo (0,000250 – 0,500) mg w próbce\nCu (0,000250 – 0,500) mg w próbce\nMn (0,000250 – 0,500) mg w próbce\nNi (0,000500 – 0,500) mg w próbce\nPb (0,00250 – 2,50) mg w próbce\nTl (0,000500 – 0,0500) mg w próbce\nV (0,00250 – 0,0500) mg w próbce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN 14385:2025:05 Srodowisko ogolne – probki gazow odlotowych pobrane na filtry Zawartosc pierwiastkow:\nZakres:\nCd (0,000250 – 0,500) mg w probce\nCr (0,000250 – 0,500) mg w probce\nCo (0,000250 – 0,500) mg w probce\nCu (0,000250 – 0,500) mg w probce\nMn (0,000250 – 0,500) mg w probce\nNi (0,000500 – 0,500) mg w probce\nPb (0,00250 – 2,50) mg w probce\nTl (0,000500 – 0,0500) mg w probce\nV (0,00250 – 0,0500) mg w probce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN 14385:2025:05","categories":["environment"],"row_index":643,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element content:","parameters_en":[{"name":"Cd","range":"(0,000250 – 0,500) mg w próbce"},{"name":"Cr","range":"(0,000250 – 0,500) mg w próbce"},{"name":"Co","range":"(0,000250 – 0,500) mg w próbce"},{"name":"Cu","range":"(0,000250 – 0,500) mg w próbce"},{"name":"Mn","range":"(0,000250 – 0,500) mg w próbce"},{"name":"Ni","range":"(0,000500 – 0,500) mg w próbce"},{"name":"Pb","range":"(0,00250 – 2,50) mg w próbce"},{"name":"Tl","range":"(0,000500 – 0,0500) mg w próbce"},{"name":"V","range":"(0,00250 – 0,0500) mg w próbce"}],"search_en":"General environment – waste gas samples collected on filters Element content: Inductively coupled plasma optical emission spectrometry (ICP-OES) Cd Cr Co Cu Mn Ni Pb Tl V PN-EN 14385:2025:05","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"General environment – waste gas samples collected on filters","methodology_zh":"元素含量：","parameters_zh":[{"name":"Cd","range":"(0,000250 – 0,500) mg w próbce"},{"name":"Cr","range":"(0,000250 – 0,500) mg w próbce"},{"name":"Co","range":"(0,000250 – 0,500) mg w próbce"},{"name":"Cu","range":"(0,000250 – 0,500) mg w próbce"},{"name":"Mn","range":"(0,000250 – 0,500) mg w próbce"},{"name":"Ni","range":"(0,000500 – 0,500) mg w próbce"},{"name":"Pb","range":"(0,00250 – 2,50) mg w próbce"},{"name":"Tl","range":"(0,000500 – 0,0500) mg w próbce"},{"name":"V","range":"(0,00250 – 0,0500) mg w próbce"}],"search_zh":"一般环境 — 用滤膜采集的废气样品 元素含量： 电感耦合等离子体原子发射光谱法（ICP-OES） Cd Cr Co Cu Mn Ni Pb Tl V PN-EN 14385:2025:05","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"一般环境 — 用滤膜采集的废气样品"},{"_id":"6a836fb9af14b9c0e7b1ed9b","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko ogólne – próbki gazów odlotowych pobrane na filtry","methodology":"Zawartość rtęci","parameters":[{"name":"Zakres","range":"(0,0005 – 0,05) mg w próbce"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES)"],"computed":[],"activity":"Zawartość rtęci\nZakres (0,0005 – 0,05) mg w próbce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES)","reference":"PN-EN 13211:2006","norm_bases":["PN-EN 13211:2006"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – próbki gazów odlotowych pobrane na filtry Zawartość rtęci\nZakres (0,0005 – 0,05) mg w próbce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES) PN-EN 13211:2006 Srodowisko ogolne – probki gazow odlotowych pobrane na filtry Zawartosc rteci\nZakres (0,0005 – 0,05) mg w probce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej z generowaniem wodorkow (HG-ICP-OES) PN-EN 13211:2006","categories":["environment"],"row_index":644,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury content","parameters_en":[{"name":"Range","range":"(0,0005 – 0,05) mg w próbce"}],"search_en":"General environment – waste gas samples collected on filters Mercury content Hydride generation inductively coupled plasma optical emission spectrometry (HG-ICP-OES) Range PN-EN 13211:2006","technique_en":"Hydride generation inductively coupled plasma optical emission spectrometry (HG-ICP-OES)","test_object_en":"General environment – waste gas samples collected on filters","methodology_zh":"汞含量","parameters_zh":[{"name":"范围","range":"(0,0005 – 0,05) mg w próbce"}],"search_zh":"一般环境 — 用滤膜采集的废气样品 汞含量 氢化物发生电感耦合等离子体发射光谱法（HG-ICP-OES） 范围 PN-EN 13211:2006","technique_zh":"氢化物发生电感耦合等离子体发射光谱法（HG-ICP-OES）","test_object_zh":"一般环境 — 用滤膜采集的废气样品"},{"_id":"6a836fb9af14b9c0e7b1ed9c","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko ogólne – próbki gazów odlotowych pobrane do roztworów pochłaniających","methodology":"Zawartość pierwiastków:","parameters":[{"name":"Cd (0,000500 – 1,00) mg w próbce Cr (0,000500 – 1,00) mg w próbce Co (0,000500 – 1,00) mg w próbce Cu (0,000200 – 1,00) mg w próbce Mn (0,000200 – 1,00) mg w próbce Ni (0,00100 – 1,00) mg w próbce Pb (0,00500 – 5,00) mg w próbce Tl (0,00100 – 0,100) mg w próbce V (0,00500 – 0,100) mg w próbce"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość pierwiastków:\nCd (0,000500 – 1,00) mg w próbce Cr (0,000500 – 1,00) mg w próbce Co (0,000500 – 1,00) mg w próbce Cu (0,000200 – 1,00) mg w próbce Mn (0,000200 – 1,00) mg w próbce Ni (0,00100 – 1,00) mg w próbce Pb (0,00500 – 5,00) mg w próbce Tl (0,00100 – 0,100) mg w próbce V (0,00500 – 0,100) mg w próbce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN 14385:2025:05","norm_bases":["PN-EN 14385:2025:05"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – próbki gazów odlotowych pobrane do roztworów pochłaniających Zawartość pierwiastków:\nCd (0,000500 – 1,00) mg w próbce Cr (0,000500 – 1,00) mg w próbce Co (0,000500 – 1,00) mg w próbce Cu (0,000200 – 1,00) mg w próbce Mn (0,000200 – 1,00) mg w próbce Ni (0,00100 – 1,00) mg w próbce Pb (0,00500 – 5,00) mg w próbce Tl (0,00100 – 0,100) mg w próbce V (0,00500 – 0,100) mg w próbce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN 14385:2025:05 Srodowisko ogolne – probki gazow odlotowych pobrane do roztworow pochlaniajacych Zawartosc pierwiastkow:\nCd (0,000500 – 1,00) mg w probce Cr (0,000500 – 1,00) mg w probce Co (0,000500 – 1,00) mg w probce Cu (0,000200 – 1,00) mg w probce Mn (0,000200 – 1,00) mg w probce Ni (0,00100 – 1,00) mg w probce Pb (0,00500 – 5,00) mg w probce Tl (0,00100 – 0,100) mg w probce V (0,00500 – 0,100) mg w probce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN 14385:2025:05","categories":["environment"],"row_index":645,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element content:","search_en":"General environment – waste gas samples collected into absorbing solutions Element content: Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN 14385:2025:05","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"General environment – waste gas samples collected into absorbing solutions","methodology_zh":"元素含量：","search_zh":"一般环境 － 采集于吸收液中的排放气体样品 元素含量： 电感耦合等离子体原子发射光谱法（ICP-OES） PN-EN 14385:2025:05","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"一般环境 － 采集于吸收液中的排放气体样品"},{"_id":"6a836fb9af14b9c0e7b1ed9d","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko ogólne – próbki gazów odlotowych pobrane do roztworów pochłaniających","methodology":"Zawartość arsenu, antymonu","parameters":[{"name":"As","range":"(0,00100 – 0,100) mg w próbce"},{"name":"Sb","range":"(0,00200 – 0,100) mg w próbce"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES)"],"computed":[],"activity":"Zawartość arsenu, antymonu\nZakres:\nAs (0,00100 – 0,100) mg w próbce\nSb (0,00200 – 0,100) mg w próbce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES)","reference":"PN-EN 14385:2025:05","norm_bases":["PN-EN 14385:2025:05"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – próbki gazów odlotowych pobrane do roztworów pochłaniających Zawartość arsenu, antymonu\nZakres:\nAs (0,00100 – 0,100) mg w próbce\nSb (0,00200 – 0,100) mg w próbce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES) PN-EN 14385:2025:05 Srodowisko ogolne – probki gazow odlotowych pobrane do roztworow pochlaniajacych Zawartosc arsenu, antymonu\nZakres:\nAs (0,00100 – 0,100) mg w probce\nSb (0,00200 – 0,100) mg w probce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej z generowaniem wodorkow (HG-ICP-OES) PN-EN 14385:2025:05","categories":["environment"],"row_index":646,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Arsenic, antimony content","parameters_en":[{"name":"As","range":"(0,00100 – 0,100) mg w próbce"},{"name":"Sb","range":"(0,00200 – 0,100) mg w próbce"}],"search_en":"General environment – waste gas samples collected into absorbing solutions Arsenic, antimony content Hydride generation inductively coupled plasma optical emission spectrometry (HG-ICP-OES) As Sb PN-EN 14385:2025:05","technique_en":"Hydride generation inductively coupled plasma optical emission spectrometry (HG-ICP-OES)","test_object_en":"General environment – waste gas samples collected into absorbing solutions","parameters_zh":[{"name":"As","range":"(0,00100 – 0,100) mg w próbce"},{"name":"Sb","range":"(0,00200 – 0,100) mg w próbce"}],"search_zh":"一般环境 － 采集于吸收液中的排放气体样品 氢化物发生电感耦合等离子体发射光谱法（HG-ICP-OES） As Sb PN-EN 14385:2025:05","technique_zh":"氢化物发生电感耦合等离子体发射光谱法（HG-ICP-OES）","test_object_zh":"一般环境 － 采集于吸收液中的排放气体样品"},{"_id":"6a836fb9af14b9c0e7b1ed9e","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko ogólne – próbki gazów odlotowych pobrane do roztworów pochłaniających","methodology":"Zawartość rtęci","parameters":[{"name":"Zakres","range":"(0,000500 – 0,0500) mg w"},{"name":"próbce"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES)"],"computed":[],"activity":"Zawartość rtęci\nZakres:\nZakres (0,000500 – 0,0500) mg w\npróbce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES)","reference":"PN-EN 13211:2006","norm_bases":["PN-EN 13211:2006"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – próbki gazów odlotowych pobrane do roztworów pochłaniających Zawartość rtęci\nZakres:\nZakres (0,000500 – 0,0500) mg w\npróbce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES) PN-EN 13211:2006 Srodowisko ogolne – probki gazow odlotowych pobrane do roztworow pochlaniajacych Zawartosc rteci\nZakres:\nZakres (0,000500 – 0,0500) mg w\nprobce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej z generowaniem wodorkow (HG-ICP-OES) PN-EN 13211:2006","categories":["environment"],"row_index":647,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury content","parameters_en":[{"name":"Range","range":"(0,000500 – 0,0500) mg w"},{"name":"sample"}],"search_en":"General environment – waste gas samples collected into absorbing solutions Mercury content Hydride generation inductively coupled plasma optical emission spectrometry (HG-ICP-OES) Range sample PN-EN 13211:2006","technique_en":"Hydride generation inductively coupled plasma optical emission spectrometry (HG-ICP-OES)","test_object_en":"General environment – waste gas samples collected into absorbing solutions","methodology_zh":"汞含量","parameters_zh":[{"name":"范围","range":"(0,000500 – 0,0500) mg w"},{"name":"样品中"}],"search_zh":"一般环境 － 采集于吸收液中的排放气体样品 汞含量 氢化物发生电感耦合等离子体发射光谱法（HG-ICP-OES） 范围 样品中 PN-EN 13211:2006","technique_zh":"氢化物发生电感耦合等离子体发射光谱法（HG-ICP-OES）","test_object_zh":"一般环境 － 采集于吸收液中的排放气体样品"},{"_id":"6a836fb9af14b9c0e7b1ed9f","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko ogólne – próbki gazów odlotowych pobrane do roztworów pochłaniających","methodology":"Zawartość chlorowodoru","parameters":[{"name":"Zakres","range":"(0,050 – 100) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość chlorowodoru\nZakres (0,050 – 100) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-EN 1911:2011","norm_bases":["PN-EN 1911:2011"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – próbki gazów odlotowych pobrane do roztworów pochłaniających Zawartość chlorowodoru\nZakres (0,050 – 100) mg w próbce\nMetoda spektrofotometryczna PN-EN 1911:2011 Srodowisko ogolne – probki gazow odlotowych pobrane do roztworow pochlaniajacych Zawartosc chlorowodoru\nZakres (0,050 – 100) mg w probce\nMetoda spektrofotometryczna PN-EN 1911:2011","categories":["environment"],"row_index":648,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrogen chloride content","parameters_en":[{"name":"Range","range":"(0,050 – 100) mg w próbce"}],"search_en":"General environment – waste gas samples collected into absorbing solutions Hydrogen chloride content Spectrophotometric method Range PN-EN 1911:2011","technique_en":"Spectrophotometric method","test_object_en":"General environment – waste gas samples collected into absorbing solutions","parameters_zh":[{"name":"范围","range":"(0,050 – 100) mg w próbce"}],"search_zh":"一般环境 － 采集于吸收液中的排放气体样品 氯化氢含量 分光光度法 范围 PN-EN 1911:2011","technique_zh":"分光光度法","methodology_zh":"氯化氢含量","test_object_zh":"一般环境 － 采集于吸收液中的排放气体样品"},{"_id":"6a836fb9af14b9c0e7b1eda0","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko ogólne – próbki gazów odlotowych pobrane do roztworów pochłaniających","methodology":"Zawartość bromowodoru","parameters":[{"name":"Zakres","range":"(0,028 – 1,0) mg w próbce"}],"technique":"Metoda turbidymetryczna","techniques":["Metoda turbidymetryczna"],"computed":[],"activity":"Zawartość bromowodoru\nZakres (0,028 – 1,0) mg w próbce\nMetoda turbidymetryczna","reference":"Metoda nr 201 Wydanie 1 z dnia 26.09.2019","norm_bases":["Metoda nr 201 Wydanie 1 z dnia 26.09.2019"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – próbki gazów odlotowych pobrane do roztworów pochłaniających Zawartość bromowodoru\nZakres (0,028 – 1,0) mg w próbce\nMetoda turbidymetryczna Metoda nr 201 Wydanie 1 z dnia 26.09.2019 Srodowisko ogolne – probki gazow odlotowych pobrane do roztworow pochlaniajacych Zawartosc bromowodoru\nZakres (0,028 – 1,0) mg w probce\nMetoda turbidymetryczna Metoda nr 201 Wydanie 1 z dnia 26.09.2019","categories":["environment"],"row_index":649,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrogen bromide content","parameters_en":[{"name":"Range","range":"(0,028 – 1,0) mg w próbce"}],"search_en":"General environment – waste gas samples collected into absorbing solutions Hydrogen bromide content Turbidimetric method Range Metoda nr 201 Wydanie 1 z dnia 26.09.2019","technique_en":"Turbidimetric method","test_object_en":"General environment – waste gas samples collected into absorbing solutions","parameters_zh":[{"name":"范围","range":"(0,028 – 1,0) mg w próbce"}],"search_zh":"一般环境 － 采集于吸收液中的排放气体样品 浊度法 范围 Metoda nr 201 Wydanie 1 z dnia 26.09.2019","technique_zh":"浊度法","test_object_zh":"一般环境 － 采集于吸收液中的排放气体样品"},{"_id":"6a836fb9af14b9c0e7b1eda1","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko ogólne - próbki gazów odlotowych pobrane do roztworów pochłaniających","methodology":"Zawartość amoniaku","parameters":[{"name":"Zakres","range":"(0,0061 – 9,7) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość amoniaku\nZakres (0,0061 – 9,7) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-EN ISO 21877:2020-03","norm_bases":["PN-EN ISO 21877:2020-03"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne - próbki gazów odlotowych pobrane do roztworów pochłaniających Zawartość amoniaku\nZakres (0,0061 – 9,7) mg w próbce\nMetoda spektrofotometryczna PN-EN ISO 21877:2020-03 Srodowisko ogolne - probki gazow odlotowych pobrane do roztworow pochlaniajacych Zawartosc amoniaku\nZakres (0,0061 – 9,7) mg w probce\nMetoda spektrofotometryczna PN-EN ISO 21877:2020-03","categories":["environment"],"row_index":650,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonia content","parameters_en":[{"name":"Range","range":"(0,0061 – 9,7) mg w próbce"}],"search_en":"General environment - waste gas samples collected into absorbing solutions Ammonia content Spectrophotometric method Range PN-EN ISO 21877:2020-03","technique_en":"Spectrophotometric method","test_object_en":"General environment - waste gas samples collected into absorbing solutions","parameters_zh":[{"name":"范围","range":"(0,0061 – 9,7) mg w próbce"}],"search_zh":"一般环境 － 采集于吸收液中的排放气体样品 氨含量 分光光度法 范围 PN-EN ISO 21877:2020-03","technique_zh":"分光光度法","methodology_zh":"氨含量","test_object_zh":"一般环境 － 采集于吸收液中的排放气体样品"},{"_id":"6a836fb9af14b9c0e7b1eda2","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko ogólne – próbki powietrza atmosferycznego pobrane na rurki z sorbentem","methodology":"Zawartość chlorku winylu","parameters":[{"name":"Zakres","range":"(0,020 – 0,50) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość chlorku winylu\nZakres (0,020 – 0,50) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Metoda nr 202 Wydanie 1 z dnia 26.09.2019","norm_bases":["Metoda nr 202 Wydanie 1 z dnia 26.09.2019"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – próbki powietrza atmosferycznego pobrane na rurki z sorbentem Zawartość chlorku winylu\nZakres (0,020 – 0,50) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Metoda nr 202 Wydanie 1 z dnia 26.09.2019 Srodowisko ogolne – probki powietrza atmosferycznego pobrane na rurki z sorbentem Zawartosc chlorku winylu\nZakres (0,020 – 0,50) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Metoda nr 202 Wydanie 1 z dnia 26.09.2019","categories":["environment"],"row_index":651,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Vinyl chloride content","parameters_en":[{"name":"Range","range":"(0,020 – 0,50) μg w próbce"}],"search_en":"General environment – ambient air samples collected on sorbent tubes Vinyl chloride content Gas chromatography with flame ionization detection (GC-FID) Range Metoda nr 202 Wydanie 1 z dnia 26.09.2019","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"General environment – ambient air samples collected on sorbent tubes","parameters_zh":[{"name":"范围","range":"(0,020 – 0,50) μg w próbce"}],"search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） 范围 Metoda nr 202 Wydanie 1 z dnia 26.09.2019","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a836fb9af14b9c0e7b1eda3","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Środowisko ogólne – próbki powietrza atmosferycznego pobrane na rurki z sorbentem","methodology":"Zawartość 1,2-dichloroetanu","parameters":[{"name":"Zakres","range":"(0,10 – 2,0) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość 1,2-dichloroetanu\nZakres (0,10 – 2,0) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Metoda nr 202 Wydanie 1 z dnia 26.09.2019","norm_bases":["Metoda nr 202 Wydanie 1 z dnia 26.09.2019"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – próbki powietrza atmosferycznego pobrane na rurki z sorbentem Zawartość 1,2-dichloroetanu\nZakres (0,10 – 2,0) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Metoda nr 202 Wydanie 1 z dnia 26.09.2019 Srodowisko ogolne – probki powietrza atmosferycznego pobrane na rurki z sorbentem Zawartosc 1,2-dichloroetanu\nZakres (0,10 – 2,0) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Metoda nr 202 Wydanie 1 z dnia 26.09.2019","categories":["environment"],"row_index":652,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"1,2-dichloroethane content","parameters_en":[{"name":"Range","range":"(0,10 – 2,0) μg w próbce"}],"search_en":"General environment – ambient air samples collected on sorbent tubes 1,2-dichloroethane content Gas chromatography with flame ionization detection (GC-FID) Range Metoda nr 202 Wydanie 1 z dnia 26.09.2019","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"General environment – ambient air samples collected on sorbent tubes","parameters_zh":[{"name":"范围","range":"(0,10 – 2,0) μg w próbce"}],"search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） 范围 Metoda nr 202 Wydanie 1 z dnia 26.09.2019","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a836fb9af14b9c0e7b1eda4","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Gleba","methodology":"Sucha masa","parameters":[{"name":"Zakres","range":"(10,0 – 999) g/kg"},{"name":"Zakres","range":"(1,0 – 99,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha masa\nZakres:\nZakres (10,0 – 999) g/kg\nZakres (1,0 – 99,0) %\nMetoda wagowa","reference":"PN-ISO 11465:1999","norm_bases":["PN-ISO 11465:1999"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Sucha masa\nZakres:\nZakres (10,0 – 999) g/kg\nZakres (1,0 – 99,0) %\nMetoda wagowa PN-ISO 11465:1999 Gleba Sucha masa\nZakres:\nZakres (10,0 – 999) g/kg\nZakres (1,0 – 99,0) %\nMetoda wagowa PN-ISO 11465:1999","categories":["environment"],"row_index":653,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry matter","parameters_en":[{"name":"Range","range":"(10,0 – 999) g/kg"},{"name":"Range","range":"(1,0 – 99,0) %"}],"search_en":"Soil Dry matter Gravimetric method Range Range PN-ISO 11465:1999","technique_en":"Gravimetric method","test_object_en":"Soil","methodology_zh":"干物质","parameters_zh":[{"name":"范围","range":"(10,0 – 999) g/kg"},{"name":"范围","range":"(1,0 – 99,0) %"}],"search_zh":"土壤 干物质 重量法 范围 范围 PN-ISO 11465:1999","technique_zh":"重量法","test_object_zh":"土壤"},{"_id":"6a836fb9af14b9c0e7b1eda5","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Gleba","methodology":"Steżenie węglowodorów C6-C12","parameters":[{"name":"Zakres","range":"(12,5 – 10000) mg/kg"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Steżenie węglowodorów C6-C12\nZakres (12,5 – 10000) mg/kg\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN ISO 16703:2011","norm_bases":["PN-EN ISO 16703:2011"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Steżenie węglowodorów C6-C12\nZakres (12,5 – 10000) mg/kg\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN ISO 16703:2011 Gleba Stezenie weglowodorow C6-C12\nZakres (12,5 – 10000) mg/kg\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN ISO 16703:2011","categories":["environment"],"row_index":654,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of C6-C12 hydrocarbons","parameters_en":[{"name":"Range","range":"(12,5 – 10000) mg/kg"}],"search_en":"Soil Concentration of C6-C12 hydrocarbons Gas chromatography with flame ionization detection (GC-FID) Range PN-EN ISO 16703:2011","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"(12,5 – 10000) mg/kg"}],"search_zh":"土壤 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-EN ISO 16703:2011","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"土壤"},{"_id":"6a836fb9af14b9c0e7b1eda6","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Gleba","methodology":"Stężenie węglowodorów C12-C35","parameters":[{"name":"Zakres","range":"(12,5 – 10000) mg/kg"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie węglowodorów C12-C35\nZakres (12,5 – 10000) mg/kg\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN ISO 16703:2011","norm_bases":["PN-EN ISO 16703:2011"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Stężenie węglowodorów C12-C35\nZakres (12,5 – 10000) mg/kg\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN ISO 16703:2011 Gleba Stezenie weglowodorow C12-C35\nZakres (12,5 – 10000) mg/kg\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN ISO 16703:2011","categories":["environment"],"row_index":655,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of C12-C35 hydrocarbons","parameters_en":[{"name":"Range","range":"(12,5 – 10000) mg/kg"}],"search_en":"Soil Concentration of C12-C35 hydrocarbons Gas chromatography with flame ionization detection (GC-FID) Range PN-EN ISO 16703:2011","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"(12,5 – 10000) mg/kg"}],"search_zh":"土壤 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-EN ISO 16703:2011","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"土壤"},{"_id":"6a836fb9af14b9c0e7b1eda7","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Gleba","methodology":"Suma węglowodorów C6-C35 (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma węglowodorów C6-C35 (z obliczeń)","reference":"PN-EN ISO 16703:2011","norm_bases":["PN-EN ISO 16703:2011"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Suma węglowodorów C6-C35 (z obliczeń) PN-EN ISO 16703:2011 Gleba Suma weglowodorow C6-C35 (z obliczen) PN-EN ISO 16703:2011","categories":["environment"],"row_index":656,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of C6-C35 hydrocarbons (calculated)","search_en":"Soil Sum of C6-C35 hydrocarbons (calculated) PN-EN ISO 16703:2011","test_object_en":"Soil","search_zh":"土壤 PN-EN ISO 16703:2011","test_object_zh":"土壤"},{"_id":"6a836fb9af14b9c0e7b1eda8","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Osady ściekowe, Odpady O: kod 19 08 05","methodology":"Sucha pozostałość","parameters":[{"name":"Zakres","range":"(10,0 – 990) g/kg"},{"name":"Zakres","range":"(1,0 – 99,0) %"},{"name":"Zawartość wody"},{"name":"Zakres","range":"(1,0 – 99,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha pozostałość\nZakres:\nZakres (10,0 – 990) g/kg\nZakres (1,0 – 99,0) %\nZawartość wody\nZakres (1,0 – 99,0) %\nMetoda wagowa","reference":"PN-EN 15934:2013-02","norm_bases":["PN-EN 15934:2013-02"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":"O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Osady ściekowe, Odpady O: kod 19 08 05 Sucha pozostałość\nZakres:\nZakres (10,0 – 990) g/kg\nZakres (1,0 – 99,0) %\nZawartość wody\nZakres (1,0 – 99,0) %\nMetoda wagowa PN-EN 15934:2013-02 Osady sciekowe, Odpady O: kod 19 08 05 Sucha pozostalosc\nZakres:\nZakres (10,0 – 990) g/kg\nZakres (1,0 – 99,0) %\nZawartosc wody\nZakres (1,0 – 99,0) %\nMetoda wagowa PN-EN 15934:2013-02","categories":["water","environment"],"row_index":657,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry residue","parameters_en":[{"name":"Range","range":"(10,0 – 990) g/kg"},{"name":"Range","range":"(1,0 – 99,0) %"},{"name":"Water content"},{"name":"Range","range":"(1,0 – 99,0) %"}],"search_en":"Sewage sludge, Waste O: code 19 08 05 Dry residue Gravimetric method Range Range Water content Range PN-EN 15934:2013-02","technique_en":"Gravimetric method","test_object_en":"Sewage sludge, Waste O: code 19 08 05","parameters_zh":[{"name":"范围","range":"(10,0 – 990) g/kg"},{"name":"范围","range":"(1,0 – 99,0) %"},{"name":"水分含量"},{"name":"范围","range":"(1,0 – 99,0) %"}],"search_zh":"干残渣 重量法 范围 范围 水分含量 范围 PN-EN 15934:2013-02","technique_zh":"重量法","methodology_zh":"干残渣"},{"_id":"6a836fb9af14b9c0e7b1eda9","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Osady ściekowe, Odpady O: kod 19 08 05","methodology":"Straty przy prażeniu suchej masy","parameters":[{"name":"Zakres","range":"(2,0 – 98,0)%"},{"name":"Pozostałość po prażeniu suchej masy (z obliczeń)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Straty przy prażeniu suchej masy\nZakres:\nZakres (2,0 – 98,0)%\nPozostałość po prażeniu suchej masy (z obliczeń)\nMetoda wagowa","reference":"PN-EN 15935:2022-01","norm_bases":["PN-EN 15935:2022-01"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":"O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Osady ściekowe, Odpady O: kod 19 08 05 Straty przy prażeniu suchej masy\nZakres:\nZakres (2,0 – 98,0)%\nPozostałość po prażeniu suchej masy (z obliczeń)\nMetoda wagowa PN-EN 15935:2022-01 Osady sciekowe, Odpady O: kod 19 08 05 Straty przy prazeniu suchej masy\nZakres:\nZakres (2,0 – 98,0)%\nPozostalosc po prazeniu suchej masy (z obliczen)\nMetoda wagowa PN-EN 15935:2022-01","categories":["water","environment"],"row_index":658,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Loss on ignition of dry matter","parameters_en":[{"name":"Range","range":"(2,0 – 98,0)%"},{"name":"Pozostałość po prażeniu suchej masy (z obliczeń)"}],"search_en":"Sewage sludge, Waste O: code 19 08 05 Loss on ignition of dry matter Gravimetric method Range PN-EN 15935:2022-01","technique_en":"Gravimetric method","test_object_en":"Sewage sludge, Waste O: code 19 08 05","parameters_zh":[{"name":"范围","range":"(2,0 – 98,0)%"},{"name":"Pozostałość po prażeniu suchej masy (z obliczeń)"}],"search_zh":"干物质烧失量 重量法 范围 PN-EN 15935:2022-01","technique_zh":"重量法","methodology_zh":"干物质烧失量"},{"_id":"6a836fb9af14b9c0e7b1edaa","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: wodór (automotive)","methodology":"Zawartość wody","parameters":[{"name":"Zakres","range":"(2,00 – 20,00) μmol/mol"}],"technique":"Metoda spektrometrii strat we wnęce optycznej z falą ciągłą (CRDS)","techniques":["Metoda spektrometrii strat we wnęce optycznej z falą ciągłą (CRDS)"],"computed":[],"activity":"Zawartość wody\nZakres (2,00 – 20,00) μmol/mol\nMetoda spektrometrii strat we wnęce optycznej z falą ciągłą (CRDS)","reference":"ASTM D7941/D7941M-23","norm_bases":["ASTM D7941/D7941M-23"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: wodór (automotive) Zawartość wody\nZakres (2,00 – 20,00) μmol/mol\nMetoda spektrometrii strat we wnęce optycznej z falą ciągłą (CRDS) ASTM D7941/D7941M-23 Paliwa gazowe: wodor (automotive) Zawartosc wody\nZakres (2,00 – 20,00) μmol/mol\nMetoda spektrometrii strat we wnece optycznej z fala ciagla (CRDS) ASTM D7941/D7941M-23","categories":["water","petro","automotive"],"row_index":659,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water content","parameters_en":[{"name":"Range","range":"(2,00 – 20,00) μmol/mol"}],"search_en":"Gaseous fuels: hydrogen (automotive) Water content Continuous-wave cavity ring-down spectrometry (CRDS) Range ASTM D7941/D7941M-23","technique_en":"Continuous-wave cavity ring-down spectrometry (CRDS)","test_object_en":"Gaseous fuels: hydrogen (automotive)","methodology_zh":"水分含量","parameters_zh":[{"name":"范围","range":"(2,00 – 20,00) μmol/mol"}],"search_zh":"气体燃料：氢（车用） 水分含量 范围 ASTM D7941/D7941M-23","test_object_zh":"气体燃料：氢（车用）"},{"_id":"6a836fb9af14b9c0e7b1edab","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: wodór (automotive)","methodology":"Zawartość helu","parameters":[{"name":"Zakres","range":"(25,0 – 600) μmol/mol"},{"name":"Zawartość ditlenku węgla, metanu i węglowodorów Ditlenek węgla","range":"(0,200 – 4,00) μmol/mol"},{"name":"Metan","range":"(10,0 – 200) μmol/mol"},{"name":"Węglowodory ogółem z wyłączeniem metanu (ekwiwalent C1)","range":"(0,100 – 4,00)"},{"name":"μmol/mol"}],"technique":"Metoda chromatografii gazowej z detektorem termokonduktometrycznym (GC-TCD); Metoda chromatografii gazowej z detektorem płomieniowo – jonizacyjnym i termokonduktometrycznym (GC-FID/TCD)","techniques":["Metoda chromatografii gazowej z detektorem termokonduktometrycznym (GC-TCD)","Metoda chromatografii gazowej z detektorem płomieniowo – jonizacyjnym i termokonduktometrycznym (GC-FID/TCD)"],"computed":[],"activity":"Zawartość helu\nZakres:\nZakres (25,0 – 600) μmol/mol\nZawartość ditlenku węgla, metanu i węglowodorów Ditlenek węgla (0,200 – 4,00) μmol/mol\nMetan (10,0 – 200) μmol/mol\nWęglowodory ogółem z wyłączeniem metanu (ekwiwalent C1) (0,100 – 4,00)\nμmol/mol\nMetoda chromatografii gazowej z detektorem termokonduktometrycznym (GC-TCD); Metoda chromatografii gazowej z detektorem płomieniowo – jonizacyjnym i termokonduktometrycznym (GC-FID/TCD)","reference":"NPL Report AS64:2011-08 p. 4.2.4 (a) | Instrukcja IT-M/TT1/99 wydanie 1 z dnia 04.06.2024 NPL Report AS64:2011-08 p. 4.2.7 (a), p. 4.2.2 (a) | Instrukcja IT-M/TT1/99 wydanie 1 z dnia 04.06.2024","norm_bases":["NPL Report AS64:2011-08 p. 4.2.4 (a)","Instrukcja IT-M/TT1/99 wydanie 1 z dnia 04.06.2024 NPL Report AS64:2011-08 p. 4.2.7 (a), p. 4.2.2 (a)","Instrukcja IT-M/TT1/99 wydanie 1 z dnia 04.06.2024"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: wodór (automotive) Zawartość helu\nZakres:\nZakres (25,0 – 600) μmol/mol\nZawartość ditlenku węgla, metanu i węglowodorów Ditlenek węgla (0,200 – 4,00) μmol/mol\nMetan (10,0 – 200) μmol/mol\nWęglowodory ogółem z wyłączeniem metanu (ekwiwalent C1) (0,100 – 4,00)\nμmol/mol\nMetoda chromatografii gazowej z detektorem termokonduktometrycznym (GC-TCD); Metoda chromatografii gazowej z detektorem płomieniowo – jonizacyjnym i termokonduktometrycznym (GC-FID/TCD) NPL Report AS64:2011-08 p. 4.2.4 (a) | Instrukcja IT-M/TT1/99 wydanie 1 z dnia 04.06.2024 NPL Report AS64:2011-08 p. 4.2.7 (a), p. 4.2.2 (a) | Instrukcja IT-M/TT1/99 wydanie 1 z dnia 04.06.2024 Paliwa gazowe: wodor (automotive) Zawartosc helu\nZakres:\nZakres (25,0 – 600) μmol/mol\nZawartosc ditlenku wegla, metanu i weglowodorow Ditlenek wegla (0,200 – 4,00) μmol/mol\nMetan (10,0 – 200) μmol/mol\nWeglowodory ogolem z wylaczeniem metanu (ekwiwalent C1) (0,100 – 4,00)\nμmol/mol\nMetoda chromatografii gazowej z detektorem termokonduktometrycznym (GC-TCD); Metoda chromatografii gazowej z detektorem plomieniowo – jonizacyjnym i termokonduktometrycznym (GC-FID/TCD) NPL Report AS64:2011-08 p. 4.2.4 (a) | Instrukcja IT-M/TT1/99 wydanie 1 z dnia 04.06.2024 NPL Report AS64:2011-08 p. 4.2.7 (a), p. 4.2.2 (a) | Instrukcja IT-M/TT1/99 wydanie 1 z dnia 04.06.2024","categories":["petro","automotive"],"row_index":660,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Helium content","parameters_en":[{"name":"Range","range":"(25,0 – 600) μmol/mol"},{"name":"Content of carbon dioxide, methane and hydrocarbons Carbon dioxide","range":"(0,200 – 4,00) μmol/mol"},{"name":"Methane","range":"(10,0 – 200) μmol/mol"},{"name":"Total hydrocarbons excluding methane (C1 equivalent)","range":"(0,100 – 4,00)"},{"name":"μmol/mol"}],"search_en":"Gaseous fuels: hydrogen (automotive) Helium content Gas chromatography with a thermal conductivity detector (GC-TCD); Gas chromatography with a flame ionization and thermal conductivity detector (GC-FID/TCD) Range Content of carbon dioxide, methane and hydrocarbons Carbon dioxide Methane Total hydrocarbons excluding methane (C1 equivalent) μmol/mol NPL Report AS64:2011-08 p. 4.2.4 (a) | Instrukcja IT-M/TT1/99 wydanie 1 z dnia 04.06.2024 NPL Report AS64:2011-08 p. 4.2.7 (a), p. 4.2.2 (a) | Instrukcja IT-M/TT1/99 wydanie 1 z dnia 04.06.2024","technique_en":"Gas chromatography with a thermal conductivity detector (GC-TCD); Gas chromatography with a flame ionization and thermal conductivity detector (GC-FID/TCD)","test_object_en":"Gaseous fuels: hydrogen (automotive)","parameters_zh":[{"name":"范围","range":"(25,0 – 600) μmol/mol"},{"name":"Zawartość ditlenku węgla, metanu i węglowodorów Ditlenek węgla","range":"(0,200 – 4,00) μmol/mol"},{"name":"甲烷","range":"(10,0 – 200) μmol/mol"},{"name":"Węglowodory ogółem z wyłączeniem metanu (ekwiwalent C1)","range":"(0,100 – 4,00)"},{"name":"μmol/mol"}],"search_zh":"气体燃料：氢（车用） 范围 甲烷 NPL Report AS64:2011-08 p. 4.2.4 (a) | Instrukcja IT-M/TT1/99 wydanie 1 z dnia 04.06.2024 NPL Report AS64:2011-08 p. 4.2.7 (a), p. 4.2.2 (a) | Instrukcja IT-M/TT1/99 wydanie 1 z dnia 04.06.2024","test_object_zh":"气体燃料：氢（车用）"},{"_id":"6a836fb9af14b9c0e7b1edac","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: wodór (automotive)","methodology":"Zawartość siarkowodoru, siarczku karbonylu i siarczku dimetylu","parameters":[{"name":"Siarkowodór","range":"(0,00050 – 0,0040)"},{"name":"μmol/mol Siarczek karbonylu","range":"(0,00050 – 0,0040)"},{"name":"μmol/mol Siarczek dimetylu","range":"(0,00050 – 0,0040)"},{"name":"μmol/mol Związki siarki ogólem (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detektorem chemiluminescencyjnym (GC-SCD)","techniques":["Metoda chromatografii gazowej z detektorem chemiluminescencyjnym (GC-SCD)"],"computed":[],"activity":"Zawartość siarkowodoru, siarczku karbonylu i siarczku dimetylu\nZakres:\nSiarkowodór (0,00050 – 0,0040)\nμmol/mol Siarczek karbonylu (0,00050 – 0,0040)\nμmol/mol Siarczek dimetylu (0,00050 – 0,0040)\nμmol/mol Związki siarki ogólem (z obliczeń)\nMetoda chromatografii gazowej z detektorem chemiluminescencyjnym (GC-SCD)","reference":"ASTM D 7652-11","norm_bases":["ASTM D 7652-11"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: wodór (automotive) Zawartość siarkowodoru, siarczku karbonylu i siarczku dimetylu\nZakres:\nSiarkowodór (0,00050 – 0,0040)\nμmol/mol Siarczek karbonylu (0,00050 – 0,0040)\nμmol/mol Siarczek dimetylu (0,00050 – 0,0040)\nμmol/mol Związki siarki ogólem (z obliczeń)\nMetoda chromatografii gazowej z detektorem chemiluminescencyjnym (GC-SCD) ASTM D 7652-11 Paliwa gazowe: wodor (automotive) Zawartosc siarkowodoru, siarczku karbonylu i siarczku dimetylu\nZakres:\nSiarkowodor (0,00050 – 0,0040)\nμmol/mol Siarczek karbonylu (0,00050 – 0,0040)\nμmol/mol Siarczek dimetylu (0,00050 – 0,0040)\nμmol/mol Zwiazki siarki ogolem (z obliczen)\nMetoda chromatografii gazowej z detektorem chemiluminescencyjnym (GC-SCD) ASTM D 7652-11","categories":["petro","automotive"],"row_index":661,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of hydrogen sulphide, carbonyl sulphide and dimethyl sulphide","parameters_en":[{"name":"Hydrogen sulfide","range":"(0,00050 – 0,0040)"},{"name":"μmol/mol Carbonyl sulfide","range":"(0,00050 – 0,0040)"},{"name":"μmol/mol Dimethyl sulfide","range":"(0,00050 – 0,0040)"},{"name":"μmol/mol Total sulfur compounds (calculated)"}],"search_en":"Gaseous fuels: hydrogen (automotive) Content of hydrogen sulphide, carbonyl sulphide and dimethyl sulphide Gas chromatography with a chemiluminescence detector (GC-SCD) Hydrogen sulfide μmol/mol Carbonyl sulfide μmol/mol Dimethyl sulfide μmol/mol Total sulfur compounds (calculated) ASTM D 7652-11","technique_en":"Gas chromatography with a chemiluminescence detector (GC-SCD)","test_object_en":"Gaseous fuels: hydrogen (automotive)","search_zh":"气体燃料：氢（车用） 硫化氢 ASTM D 7652-11","test_object_zh":"气体燃料：氢（车用）","parameters_zh":[{"name":"硫化氢","range":"(0,00050 – 0,0040)"},{"name":"μmol/mol Siarczek karbonylu","range":"(0,00050 – 0,0040)"},{"name":"μmol/mol Siarczek dimetylu","range":"(0,00050 – 0,0040)"},{"name":"μmol/mol Związki siarki ogólem (z obliczeń)"}]},{"_id":"6a836fb9af14b9c0e7b1edad","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: wodór (automotive)","methodology":"Zawartość formaldehydu i halogenków organicznych","parameters":[{"name":"Formaldehyd","range":"(0,050 – 0,40) μmol/mol"},{"name":"Zakres","range":"1,2 – dichlorobenzen (0,0010 – 0,050)"},{"name":"μmol/mol Chloroform","range":"(0,0010 – 0,050) μmol/mol"},{"name":"Dichlorometan","range":"(0,0010 – 0,050)"},{"name":"μmol/mol Tetrachloroetylen","range":"(0,0010 – 0,050)"},{"name":"μmol/mol Zawartość związków halogenowych ogółem (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detektorem mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detektorem mas (GC-MS)"],"computed":[],"activity":"Zawartość formaldehydu i halogenków organicznych\nZakres:\nFormaldehyd (0,050 – 0,40) μmol/mol\nZakres 1,2 – dichlorobenzen (0,0010 – 0,050)\nμmol/mol Chloroform (0,0010 – 0,050) μmol/mol\nDichlorometan (0,0010 – 0,050)\nμmol/mol Tetrachloroetylen (0,0010 – 0,050)\nμmol/mol Zawartość związków halogenowych ogółem (z obliczeń)\nMetoda chromatografii gazowej z detektorem mas (GC-MS)","reference":"ASTM D 7892-25","norm_bases":["ASTM D 7892-25"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: wodór (automotive) Zawartość formaldehydu i halogenków organicznych\nZakres:\nFormaldehyd (0,050 – 0,40) μmol/mol\nZakres 1,2 – dichlorobenzen (0,0010 – 0,050)\nμmol/mol Chloroform (0,0010 – 0,050) μmol/mol\nDichlorometan (0,0010 – 0,050)\nμmol/mol Tetrachloroetylen (0,0010 – 0,050)\nμmol/mol Zawartość związków halogenowych ogółem (z obliczeń)\nMetoda chromatografii gazowej z detektorem mas (GC-MS) ASTM D 7892-25 Paliwa gazowe: wodor (automotive) Zawartosc formaldehydu i halogenkow organicznych\nZakres:\nFormaldehyd (0,050 – 0,40) μmol/mol\nZakres 1,2 – dichlorobenzen (0,0010 – 0,050)\nμmol/mol Chloroform (0,0010 – 0,050) μmol/mol\nDichlorometan (0,0010 – 0,050)\nμmol/mol Tetrachloroetylen (0,0010 – 0,050)\nμmol/mol Zawartosc zwiazkow halogenowych ogolem (z obliczen)\nMetoda chromatografii gazowej z detektorem mas (GC-MS) ASTM D 7892-25","categories":["petro","automotive"],"row_index":662,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Formaldehyde and organic halide content","parameters_en":[{"name":"Formaldehyde","range":"(0,050 – 0,40) μmol/mol"},{"name":"Range","range":"1,2 – dichlorobenzen (0,0010 – 0,050)"},{"name":"μmol/mol Chloroform","range":"(0,0010 – 0,050) μmol/mol"},{"name":"Dichloromethane","range":"(0,0010 – 0,050)"},{"name":"μmol/mol Tetrachloroethylene","range":"(0,0010 – 0,050)"},{"name":"μmol/mol Content of total halogen compounds (calculated)"}],"search_en":"Gaseous fuels: hydrogen (automotive) Formaldehyde and organic halide content Gas chromatography with a mass detector (GC-MS) Formaldehyde Range μmol/mol Chloroform Dichloromethane μmol/mol Tetrachloroethylene μmol/mol Content of total halogen compounds (calculated) ASTM D 7892-25","technique_en":"Gas chromatography with a mass detector (GC-MS)","test_object_en":"Gaseous fuels: hydrogen (automotive)","parameters_zh":[{"name":"Formaldehyd","range":"(0,050 – 0,40) μmol/mol"},{"name":"范围","range":"1,2 – dichlorobenzen (0,0010 – 0,050)"},{"name":"μmol/mol Chloroform","range":"(0,0010 – 0,050) μmol/mol"},{"name":"二氯甲烷","range":"(0,0010 – 0,050)"},{"name":"μmol/mol Tetrachloroetylen","range":"(0,0010 – 0,050)"},{"name":"μmol/mol Zawartość związków halogenowych ogółem (z obliczeń)"}],"search_zh":"气体燃料：氢（车用） 范围 二氯甲烷 ASTM D 7892-25","test_object_zh":"气体燃料：氢（车用）"},{"_id":"6a836fb9af14b9c0e7b1edae","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: wodór (automotive)","methodology":"Zawartość argonu, azotu, tlenu, tlenku węgla","parameters":[{"name":"Argon","range":"(50,0 – 600) μmol/mol"},{"name":"Azot","range":"(50,0 – 600) μmol/mol"},{"name":"Tlen","range":"(3,0 – 40) μmol/mol"},{"name":"Tlenek wegla","range":"(0,0500 – 0,400)"},{"name":"μmol/mol"}],"technique":"Metoda chromatografii gazowej z detektorem wyładowań helowych (GC-PDHID)","techniques":["Metoda chromatografii gazowej z detektorem wyładowań helowych (GC-PDHID)"],"computed":[],"activity":"Zawartość argonu, azotu, tlenu, tlenku węgla\nZakres:\nArgon (50,0 – 600) μmol/mol\nAzot (50,0 – 600) μmol/mol\nTlen (3,0 – 40) μmol/mol\nTlenek wegla (0,0500 – 0,400)\nμmol/mol\nMetoda chromatografii gazowej z detektorem wyładowań helowych (GC-PDHID)","reference":"NPL Report AS64:2011-08 p.4.2.6 (b), p.4.2.5 (a), p. 4.2.3 (a), p. 4.2.8 (a) | Instrukcja IT-M/TT1/97 wydanie 1 z dnia 24.05.2024","norm_bases":["NPL Report AS64:2011-08 p.4.2.6 (b), p.4.2.5 (a), p. 4.2.3 (a), p. 4.2.8 (a)","Instrukcja IT-M/TT1/97 wydanie 1 z dnia 24.05.2024"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: wodór (automotive) Zawartość argonu, azotu, tlenu, tlenku węgla\nZakres:\nArgon (50,0 – 600) μmol/mol\nAzot (50,0 – 600) μmol/mol\nTlen (3,0 – 40) μmol/mol\nTlenek wegla (0,0500 – 0,400)\nμmol/mol\nMetoda chromatografii gazowej z detektorem wyładowań helowych (GC-PDHID) NPL Report AS64:2011-08 p.4.2.6 (b), p.4.2.5 (a), p. 4.2.3 (a), p. 4.2.8 (a) | Instrukcja IT-M/TT1/97 wydanie 1 z dnia 24.05.2024 Paliwa gazowe: wodor (automotive) Zawartosc argonu, azotu, tlenu, tlenku wegla\nZakres:\nArgon (50,0 – 600) μmol/mol\nAzot (50,0 – 600) μmol/mol\nTlen (3,0 – 40) μmol/mol\nTlenek wegla (0,0500 – 0,400)\nμmol/mol\nMetoda chromatografii gazowej z detektorem wyladowan helowych (GC-PDHID) NPL Report AS64:2011-08 p.4.2.6 (b), p.4.2.5 (a), p. 4.2.3 (a), p. 4.2.8 (a) | Instrukcja IT-M/TT1/97 wydanie 1 z dnia 24.05.2024","categories":["petro","automotive"],"row_index":663,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Argon, nitrogen, oxygen, carbon monoxide content","parameters_en":[{"name":"Argon","range":"(50,0 – 600) μmol/mol"},{"name":"Nitrogen","range":"(50,0 – 600) μmol/mol"},{"name":"Oxygen","range":"(3,0 – 40) μmol/mol"},{"name":"Carbon monoxide","range":"(0,0500 – 0,400)"},{"name":"μmol/mol"}],"search_en":"Gaseous fuels: hydrogen (automotive) Argon, nitrogen, oxygen, carbon monoxide content Gas chromatography with a pulsed discharge helium ionization detector (GC-PDHID) Argon Nitrogen Oxygen Carbon monoxide μmol/mol NPL Report AS64:2011-08 p.4.2.6 (b), p.4.2.5 (a), p. 4.2.3 (a), p. 4.2.8 (a) | Instrukcja IT-M/TT1/97 wydanie 1 z dnia 24.05.2024","technique_en":"Gas chromatography with a pulsed discharge helium ionization detector (GC-PDHID)","test_object_en":"Gaseous fuels: hydrogen (automotive)","search_zh":"气体燃料：氢（车用） 氮 氧 NPL Report AS64:2011-08 p.4.2.6 (b), p.4.2.5 (a), p. 4.2.3 (a), p. 4.2.8 (a) | Instrukcja IT-M/TT1/97 wydanie 1 z dnia 24.05.2024","test_object_zh":"气体燃料：氢（车用）","parameters_zh":[{"name":"Argon","range":"(50,0 – 600) μmol/mol"},{"name":"氮","range":"(50,0 – 600) μmol/mol"},{"name":"氧","range":"(3,0 – 40) μmol/mol"},{"name":"Tlenek wegla","range":"(0,0500 – 0,400)"},{"name":"μmol/mol"}]},{"_id":"6a836fb9af14b9c0e7b1edaf","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: wodór (automotive)","methodology":"Zawartość kwasu mrówkowego, amoniaku","parameters":[{"name":"Kwas mrówkowy","range":"(0,030 – 4,0)"},{"name":"μmol/mol Amoniak","range":"(0,020 – 4,0) μmol/mol"}],"technique":"Metoda chromatografii jonowej z detektorem konduktometrycznym (IC-CD)","techniques":["Metoda chromatografii jonowej z detektorem konduktometrycznym (IC-CD)"],"computed":[],"activity":"Zawartość kwasu mrówkowego, amoniaku\nZakres:\nKwas mrówkowy (0,030 – 4,0)\nμmol/mol Amoniak (0,020 – 4,0) μmol/mol\nMetoda chromatografii jonowej z detektorem konduktometrycznym (IC-CD)","reference":"JIS K0127:2013 | Instrukcja IT-M/TT1/102 wydanie 1 z dnia 24.06.2024","norm_bases":["JIS K0127:2013","Instrukcja IT-M/TT1/102 wydanie 1 z dnia 24.06.2024"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: wodór (automotive) Zawartość kwasu mrówkowego, amoniaku\nZakres:\nKwas mrówkowy (0,030 – 4,0)\nμmol/mol Amoniak (0,020 – 4,0) μmol/mol\nMetoda chromatografii jonowej z detektorem konduktometrycznym (IC-CD) JIS K0127:2013 | Instrukcja IT-M/TT1/102 wydanie 1 z dnia 24.06.2024 Paliwa gazowe: wodor (automotive) Zawartosc kwasu mrowkowego, amoniaku\nZakres:\nKwas mrowkowy (0,030 – 4,0)\nμmol/mol Amoniak (0,020 – 4,0) μmol/mol\nMetoda chromatografii jonowej z detektorem konduktometrycznym (IC-CD) JIS K0127:2013 | Instrukcja IT-M/TT1/102 wydanie 1 z dnia 24.06.2024","categories":["petro","automotive"],"row_index":664,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Formic acid, ammonia content","parameters_en":[{"name":"Formic acid","range":"(0,030 – 4,0)"},{"name":"μmol/mol Ammonia","range":"(0,020 – 4,0) μmol/mol"}],"search_en":"Gaseous fuels: hydrogen (automotive) Formic acid, ammonia content Ion chromatography with a conductometric detector (IC-CD) Formic acid μmol/mol Ammonia JIS K0127:2013 | Instrukcja IT-M/TT1/102 wydanie 1 z dnia 24.06.2024","technique_en":"Ion chromatography with a conductometric detector (IC-CD)","test_object_en":"Gaseous fuels: hydrogen (automotive)","search_zh":"气体燃料：氢（车用） JIS K0127:2013 | Instrukcja IT-M/TT1/102 wydanie 1 z dnia 24.06.2024","test_object_zh":"气体燃料：氢（车用）"},{"_id":"6a836fb9af14b9c0e7b1edb0","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: wodór (automotive)","methodology":"Zawartość cząstek stałych","parameters":[{"name":"Zakres","range":"(0,0500 – 5,00) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość cząstek stałych\nZakres (0,0500 – 5,00) mg/kg\nMetoda wagowa","reference":"ASTM D 7651-24e1","norm_bases":["ASTM D 7651-24e1"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: wodór (automotive) Zawartość cząstek stałych\nZakres (0,0500 – 5,00) mg/kg\nMetoda wagowa ASTM D 7651-24e1 Paliwa gazowe: wodor (automotive) Zawartosc czastek stalych\nZakres (0,0500 – 5,00) mg/kg\nMetoda wagowa ASTM D 7651-24e1","categories":["petro","automotive"],"row_index":665,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Particulate matter content","parameters_en":[{"name":"Range","range":"(0,0500 – 5,00) mg/kg"}],"search_en":"Gaseous fuels: hydrogen (automotive) Particulate matter content Gravimetric method Range ASTM D 7651-24e1","technique_en":"Gravimetric method","test_object_en":"Gaseous fuels: hydrogen (automotive)","parameters_zh":[{"name":"范围","range":"(0,0500 – 5,00) mg/kg"}],"search_zh":"气体燃料：氢（车用） 重量法 范围 ASTM D 7651-24e1","technique_zh":"重量法","test_object_zh":"气体燃料：氢（车用）"},{"_id":"6a836fb9af14b9c0e7b1edb1","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: wodór (automotive)","methodology":"Indeks paliwa wodorowego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Indeks paliwa wodorowego (z obliczeń)","reference":"ISO 14687:2019-11 p. 5.1","norm_bases":["ISO 14687:2019-11 p. 5.1"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: wodór (automotive) Indeks paliwa wodorowego (z obliczeń) ISO 14687:2019-11 p. 5.1 Paliwa gazowe: wodor (automotive) Indeks paliwa wodorowego (z obliczen) ISO 14687:2019-11 p. 5.1","categories":["petro","automotive"],"row_index":666,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrogen fuel index (calculated)","search_en":"Gaseous fuels: hydrogen (automotive) Hydrogen fuel index (calculated) ISO 14687:2019-11 p. 5.1","test_object_en":"Gaseous fuels: hydrogen (automotive)","search_zh":"气体燃料：氢（车用） ISO 14687:2019-11 p. 5.1","test_object_zh":"气体燃料：氢（车用）"},{"_id":"6a836fb9af14b9c0e7b1edb2","lab_id":"69ad52a3de79e566650fb263","country":"PL","accr_number":"AB 484","accr_body":"PCA","test_object":"Paliwa gazowe: wodór (automotive)","methodology":"Całkowita zawartość gazów innych niż wodór (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Całkowita zawartość gazów innych niż wodór (z obliczeń)","reference":"ISO 14687:2019-11 p. 5.1","norm_bases":["ISO 14687:2019-11 p. 5.1"],"lab_section":"Pracownia Nawozów i Środowiska Naturalnego TT1","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa gazowe: wodór (automotive) Całkowita zawartość gazów innych niż wodór (z obliczeń) ISO 14687:2019-11 p. 5.1 Paliwa gazowe: wodor (automotive) Calkowita zawartosc gazow innych niz wodor (z obliczen) ISO 14687:2019-11 p. 5.1","categories":["petro","automotive"],"row_index":667,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total content of gases other than hydrogen (calculated)","search_en":"Gaseous fuels: hydrogen (automotive) Total content of gases other than hydrogen (calculated) ISO 14687:2019-11 p. 5.1","test_object_en":"Gaseous fuels: hydrogen (automotive)","search_zh":"气体燃料：氢（车用） ISO 14687:2019-11 p. 5.1","test_object_zh":"气体燃料：氢（车用）"}],"has_pdf":true}