{"lab":{"_id":"69ad52a3de79e566650fb259","accr_number":"AB 473","country":"PL","accr_body":"PCA","address":"I PRODUCENTÓW MLEKA, ul. Żurawia 22, 00-515 Warszawa, LABORATORIUM W BYDGOSZCZY Z/S W MINIKOWIE, Minikowo 1B, 89-122 Minikowo","categories":["food"],"city":"Minikowo","imported_at":"2026-03-08T10:42:43.265Z","methods_count":7,"name":"POLSKA FEDERACJA HODOWCÓW BYDŁA","parse_status":"parsed","parse_version":2,"pdf_files":["AB_473.pdf"],"scope_summary":"","search_text":"polska federacja hodowców bydła i producentów mleka, ul. żurawia 22, 00-515 warszawa, laboratorium w bydgoszczy z/s w minikowie, minikowo 1b, 89-122 minikowo food pharma other","status":"active","updated_at":"2026-03-08T14:51:18.871Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:18.871Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20473,podmiot.html","fields_of_testing":[{"codes":"C/22","pl":"Badania chemiczne żywności","en":"Chemical tests of food"},{"codes":"B/22","pl":"Badania biochemiczne żywności","en":"Biochemical tests of food"}],"issue":{"no":"16","date":"16.02.2024"},"parse_date":"2026-07-20T07:09:58.491Z","parse_source":"script-pdfplumber","map_coord":[53.166787,17.741945],"map_geo":"nominatim-city","has_en":true,"category_counts":{"food":7},"category_scores":{"food":7},"has_zh":true},"methods":[{"_id":"6a5dc9c6f1c10c8ce82605e6","lab_id":"69ad52a3de79e566650fb259","country":"PL","accr_number":"AB 473","accr_body":"PCA","test_object":"Mleko surowe od krów","test_object_en":"Raw cows' milk","methodology":"Zawartość tłuszczu","methodology_en":"Fat content","parameters":[{"name":"Zakres","range":"(1,50 – 12,00) g/100g"}],"parameters_en":[{"name":"Range","range":"(1,50 – 12,00) g/100g"}],"technique":"Metoda spektrometrii w podczerwieni","techniques":["Metoda spektrometrii w podczerwieni"],"technique_en":"Infrared spectrometry method","computed":[],"computed_en":[],"activity":"Zawartość tłuszczu\nZakres (1,50 – 12,00) g/100g\nMetoda spektrometrii w podczerwieni","reference":"PN-ISO 9622:2015-09 z zastosowaniem aparatu Milkoscan FC+","norm_bases":["PN-ISO 9622:2015-09 z zastosowaniem aparatu Milkoscan FC+"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mleko surowe od krów Zawartość tłuszczu\nZakres (1,50 – 12,00) g/100g\nMetoda spektrometrii w podczerwieni PN-ISO 9622:2015-09 z zastosowaniem aparatu Milkoscan FC+ Mleko surowe od krow Zawartosc tluszczu\nZakres (1,50 – 12,00) g/100g\nMetoda spektrometrii w podczerwieni PN-ISO 9622:2015-09 z zastosowaniem aparatu Milkoscan FC+","categories":["food"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Raw cows' milk Fat content Infrared spectrometry method Range PN-ISO 9622:2015-09 z zastosowaniem aparatu Milkoscan FC+","methodology_zh":"脂肪含量","parameters_zh":[{"name":"范围","range":"(1,50 – 12,00) g/100g"}],"search_zh":"牛生鲜乳 脂肪含量 红外光谱法 范围 PN-ISO 9622:2015-09 z zastosowaniem aparatu Milkoscan FC+","technique_zh":"红外光谱法","test_object_zh":"牛生鲜乳"},{"_id":"6a5dc9c6f1c10c8ce82605e7","lab_id":"69ad52a3de79e566650fb259","country":"PL","accr_number":"AB 473","accr_body":"PCA","test_object":"Mleko surowe od krów","test_object_en":"Raw cows' milk","methodology":"Zawartość białka","methodology_en":"Protein content","parameters":[{"name":"Zakres","range":"(1,00 – 9,00) g/100g"}],"parameters_en":[{"name":"Range","range":"(1,00 – 9,00) g/100g"}],"technique":"Metoda spektrometrii w podczerwieni","techniques":["Metoda spektrometrii w podczerwieni"],"technique_en":"Infrared spectrometry method","computed":[],"computed_en":[],"activity":"Zawartość białka\nZakres (1,00 – 9,00) g/100g\nMetoda spektrometrii w podczerwieni","reference":"PN-ISO 9622:2015-09 z zastosowaniem aparatu Milkoscan FC+","norm_bases":["PN-ISO 9622:2015-09 z zastosowaniem aparatu Milkoscan FC+"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mleko surowe od krów Zawartość białka\nZakres (1,00 – 9,00) g/100g\nMetoda spektrometrii w podczerwieni PN-ISO 9622:2015-09 z zastosowaniem aparatu Milkoscan FC+ Mleko surowe od krow Zawartosc bialka\nZakres (1,00 – 9,00) g/100g\nMetoda spektrometrii w podczerwieni PN-ISO 9622:2015-09 z zastosowaniem aparatu Milkoscan FC+","categories":["food"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Raw cows' milk Protein content Infrared spectrometry method Range PN-ISO 9622:2015-09 z zastosowaniem aparatu Milkoscan FC+","methodology_zh":"蛋白质含量","parameters_zh":[{"name":"范围","range":"(1,00 – 9,00) g/100g"}],"search_zh":"牛生鲜乳 蛋白质含量 红外光谱法 范围 PN-ISO 9622:2015-09 z zastosowaniem aparatu Milkoscan FC+","technique_zh":"红外光谱法","test_object_zh":"牛生鲜乳"},{"_id":"6a5dc9c6f1c10c8ce82605e8","lab_id":"69ad52a3de79e566650fb259","country":"PL","accr_number":"AB 473","accr_body":"PCA","test_object":"Mleko surowe od krów","test_object_en":"Raw cows' milk","methodology":"Zawartość laktozy","methodology_en":"Lactose content","parameters":[{"name":"Zakres","range":"(3,00 – 6,00) g/100g"}],"parameters_en":[{"name":"Range","range":"(3,00 – 6,00) g/100g"}],"technique":"Metoda spektrometrii w podczerwieni","techniques":["Metoda spektrometrii w podczerwieni"],"technique_en":"Infrared spectrometry method","computed":[],"computed_en":[],"activity":"Zawartość laktozy\nZakres (3,00 – 6,00) g/100g\nMetoda spektrometrii w podczerwieni","reference":"PN-ISO 9622:2015-09 z zastosowaniem aparatu Milkoscan FC+","norm_bases":["PN-ISO 9622:2015-09 z zastosowaniem aparatu Milkoscan FC+"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mleko surowe od krów Zawartość laktozy\nZakres (3,00 – 6,00) g/100g\nMetoda spektrometrii w podczerwieni PN-ISO 9622:2015-09 z zastosowaniem aparatu Milkoscan FC+ Mleko surowe od krow Zawartosc laktozy\nZakres (3,00 – 6,00) g/100g\nMetoda spektrometrii w podczerwieni PN-ISO 9622:2015-09 z zastosowaniem aparatu Milkoscan FC+","categories":["food"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Raw cows' milk Lactose content Infrared spectrometry method Range PN-ISO 9622:2015-09 z zastosowaniem aparatu Milkoscan FC+","parameters_zh":[{"name":"范围","range":"(3,00 – 6,00) g/100g"}],"search_zh":"牛生鲜乳 乳糖含量 红外光谱法 范围 PN-ISO 9622:2015-09 z zastosowaniem aparatu Milkoscan FC+","technique_zh":"红外光谱法","test_object_zh":"牛生鲜乳","methodology_zh":"乳糖含量"},{"_id":"6a5dc9c6f1c10c8ce82605e9","lab_id":"69ad52a3de79e566650fb259","country":"PL","accr_number":"AB 473","accr_body":"PCA","test_object":"Mleko surowe od krów","test_object_en":"Raw cows' milk","methodology":"Zawartość suchej masy","methodology_en":"Dry matter content","parameters":[{"name":"Zakres","range":"(5,50 – 27,00) g/100g"}],"parameters_en":[{"name":"Range","range":"(5,50 – 27,00) g/100g"}],"technique":"Metoda spektrometrii w podczerwieni","techniques":["Metoda spektrometrii w podczerwieni"],"technique_en":"Infrared spectrometry method","computed":[],"computed_en":[],"activity":"Zawartość suchej masy\nZakres (5,50 – 27,00) g/100g\nMetoda spektrometrii w podczerwieni","reference":"PN-ISO 9622:2015-09 z zastosowaniem aparatu Milkoscan FC+","norm_bases":["PN-ISO 9622:2015-09 z zastosowaniem aparatu Milkoscan FC+"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mleko surowe od krów Zawartość suchej masy\nZakres (5,50 – 27,00) g/100g\nMetoda spektrometrii w podczerwieni PN-ISO 9622:2015-09 z zastosowaniem aparatu Milkoscan FC+ Mleko surowe od krow Zawartosc suchej masy\nZakres (5,50 – 27,00) g/100g\nMetoda spektrometrii w podczerwieni PN-ISO 9622:2015-09 z zastosowaniem aparatu Milkoscan FC+","categories":["food"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Raw cows' milk Dry matter content Infrared spectrometry method Range PN-ISO 9622:2015-09 z zastosowaniem aparatu Milkoscan FC+","parameters_zh":[{"name":"范围","range":"(5,50 – 27,00) g/100g"}],"search_zh":"牛生鲜乳 干物质含量 红外光谱法 范围 PN-ISO 9622:2015-09 z zastosowaniem aparatu Milkoscan FC+","technique_zh":"红外光谱法","methodology_zh":"干物质含量","test_object_zh":"牛生鲜乳"},{"_id":"6a5dc9c6f1c10c8ce82605ea","lab_id":"69ad52a3de79e566650fb259","country":"PL","accr_number":"AB 473","accr_body":"PCA","test_object":"Mleko surowe od krów","test_object_en":"Raw cows' milk","methodology":"Zawartość mocznika","methodology_en":"Urea content","parameters":[{"name":"Zakres","range":"(100 – 1000) mg/l"}],"parameters_en":[{"name":"Range","range":"(100 – 1000) mg/l"}],"technique":"Metoda spektrometrii w podczerwieni","techniques":["Metoda spektrometrii w podczerwieni"],"technique_en":"Infrared spectrometry method","computed":[],"computed_en":[],"activity":"Zawartość mocznika\nZakres (100 – 1000) mg/l\nMetoda spektrometrii w podczerwieni","reference":"PN-ISO 9622:2015-09 z zastosowaniem aparatu Milkoscan FC+","norm_bases":["PN-ISO 9622:2015-09 z zastosowaniem aparatu Milkoscan FC+"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mleko surowe od krów Zawartość mocznika\nZakres (100 – 1000) mg/l\nMetoda spektrometrii w podczerwieni PN-ISO 9622:2015-09 z zastosowaniem aparatu Milkoscan FC+ Mleko surowe od krow Zawartosc mocznika\nZakres (100 – 1000) mg/l\nMetoda spektrometrii w podczerwieni PN-ISO 9622:2015-09 z zastosowaniem aparatu Milkoscan FC+","categories":["food"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Raw cows' milk Urea content Infrared spectrometry method Range PN-ISO 9622:2015-09 z zastosowaniem aparatu Milkoscan FC+","parameters_zh":[{"name":"范围","range":"(100 – 1000) mg/l"}],"search_zh":"牛生鲜乳 尿素含量 红外光谱法 范围 PN-ISO 9622:2015-09 z zastosowaniem aparatu Milkoscan FC+","technique_zh":"红外光谱法","test_object_zh":"牛生鲜乳","methodology_zh":"尿素含量"},{"_id":"6a5dc9c6f1c10c8ce82605eb","lab_id":"69ad52a3de79e566650fb259","country":"PL","accr_number":"AB 473","accr_body":"PCA","test_object":"Mleko surowe od krów","test_object_en":"Raw cows' milk","methodology":"Zawartość kazeiny","methodology_en":"Casein content","parameters":[{"name":"Zakres","range":"(2,0 – 3,5) g/100g"}],"parameters_en":[{"name":"Range","range":"(2,0 – 3,5) g/100g"}],"technique":"Metoda spektrometrii w podczerwieni","techniques":["Metoda spektrometrii w podczerwieni"],"technique_en":"Infrared spectrometry method","computed":[],"computed_en":[],"activity":"Zawartość kazeiny\nZakres (2,0 – 3,5) g/100g\nMetoda spektrometrii w podczerwieni","reference":"PN-ISO 9622:2015-09 z zastosowaniem aparatu Milkoscan FC+","norm_bases":["PN-ISO 9622:2015-09 z zastosowaniem aparatu Milkoscan FC+"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mleko surowe od krów Zawartość kazeiny\nZakres (2,0 – 3,5) g/100g\nMetoda spektrometrii w podczerwieni PN-ISO 9622:2015-09 z zastosowaniem aparatu Milkoscan FC+ Mleko surowe od krow Zawartosc kazeiny\nZakres (2,0 – 3,5) g/100g\nMetoda spektrometrii w podczerwieni PN-ISO 9622:2015-09 z zastosowaniem aparatu Milkoscan FC+","categories":["food"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Raw cows' milk Casein content Infrared spectrometry method Range PN-ISO 9622:2015-09 z zastosowaniem aparatu Milkoscan FC+","parameters_zh":[{"name":"范围","range":"(2,0 – 3,5) g/100g"}],"search_zh":"牛生鲜乳 酪蛋白含量 红外光谱法 范围 PN-ISO 9622:2015-09 z zastosowaniem aparatu Milkoscan FC+","technique_zh":"红外光谱法","test_object_zh":"牛生鲜乳","methodology_zh":"酪蛋白含量"},{"_id":"6a5dc9c6f1c10c8ce82605ec","lab_id":"69ad52a3de79e566650fb259","country":"PL","accr_number":"AB 473","accr_body":"PCA","test_object":"Mleko surowe od krów","test_object_en":"Raw cows' milk","methodology":"Liczba komórek somatycznych","methodology_en":"Somatic cell count","parameters":[{"name":"Zakres","range":"(5 x103 – 2 x 106) komórek/ml"}],"parameters_en":[{"name":"Range","range":"(5 x103 – 2 x 106) komórek/ml"}],"technique":"Metoda cytometrii przepływowej","techniques":["Metoda cytometrii przepływowej"],"technique_en":"Flow cytometry method","computed":[],"computed_en":[],"activity":"Liczba komórek somatycznych\nZakres (5 x103 – 2 x 106) komórek/ml\nMetoda cytometrii przepływowej","reference":"PN-EN ISO 13366-2:2007 z zastosowaniem aparatu Fossomatic FC","norm_bases":["PN-EN ISO 13366-2:2007 z zastosowaniem aparatu Fossomatic FC"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mleko surowe od krów Liczba komórek somatycznych\nZakres (5 x103 – 2 x 106) komórek/ml\nMetoda cytometrii przepływowej PN-EN ISO 13366-2:2007 z zastosowaniem aparatu Fossomatic FC Mleko surowe od krow Liczba komorek somatycznych\nZakres (5 x103 – 2 x 106) komorek/ml\nMetoda cytometrii przeplywowej PN-EN ISO 13366-2:2007 z zastosowaniem aparatu Fossomatic FC","categories":["food"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Raw cows' milk Somatic cell count Flow cytometry method Range PN-EN ISO 13366-2:2007 z zastosowaniem aparatu Fossomatic FC","methodology_zh":"体细胞计数","parameters_zh":[{"name":"范围","range":"(5 x103 – 2 x 106) komórek/ml"}],"search_zh":"牛生鲜乳 体细胞计数 流式细胞术 范围 PN-EN ISO 13366-2:2007 z zastosowaniem aparatu Fossomatic FC","technique_zh":"流式细胞术","test_object_zh":"牛生鲜乳"}],"has_pdf":true}