{"lab":{"_id":"69ad52a3de79e566650fb247","accr_number":"AB 457","country":"PL","accr_body":"PCA","address":"ul. Składowa 7, 62-600 Koło","categories":["food","microbiology"],"city":"Koło","imported_at":"2026-03-08T10:42:43.265Z","methods_count":6,"name":"LABORATORIUM OCENY MLEKA W KOLE Sp. z o.o.","parse_status":"parsed","parse_version":2,"pdf_files":["AB_457.pdf"],"scope_summary":"","search_text":"laboratorium oceny mleka w kole sp. z o.o. ul. składowa 7, 62-600 koło food microbiology pharma other","status":"active","updated_at":"2026-03-08T14:51:18.161Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:18.161Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20457,podmiot.html","fields_of_testing":[{"codes":"B/22","pl":"Badania biologiczne i biochemiczne żywności","en":"Biological and biochemical tests of food"},{"codes":"C/22","pl":"Badania chemiczne żywności","en":"Chemical tests od food"},{"codes":"K/22","pl":"Badania mikrobiologiczne żywności","en":"Microbiological tests of food"}],"issue":{"no":"15","date":"15.10.2025"},"parse_date":"2026-07-20T07:09:39.289Z","parse_source":"script-pdfplumber","map_coord":[52.212459,18.627591],"map_geo":"nominatim-street","has_zh":true,"has_en":true,"category_counts":{"food":6,"microbiology":1},"category_scores":{"food":5.14,"microbiology":0.14}},"methods":[{"_id":"6a5dc9b3f1c10c8ce825c16f","lab_id":"69ad52a3de79e566650fb247","country":"PL","accr_number":"AB 457","accr_body":"PCA","test_object":"Mleko surowe","test_object_en":"Raw milk","methodology":"Ogólna liczba drobnoustrojów","methodology_en":"Total viable count","parameters":[{"name":"od 1 х 103 do 1 х 106 jtk/ml"}],"parameters_en":[{"name":"from 1 х 103 to 1 х 106 CFU/ml"}],"technique":"Metoda cytometrii przepływowej","techniques":["Metoda cytometrii przepływowej"],"technique_en":"Flow cytometry method","computed":[],"computed_en":[],"activity":"Ogólna liczba drobnoustrojów\nod 1 х 103 do 1 х 106 jtk/ml\nMetoda cytometrii przepływowej","reference":"PB-03 wdanie 1/2013 data wydania 30.04.2013 r. w oparciu o instrukcję aparatu BactoScan FC","norm_bases":["PB-03 wdanie 1/2013 data wydania 30.04.2013 r. w oparciu o instrukcję aparatu BactoScan FC"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mleko surowe Ogólna liczba drobnoustrojów\nod 1 х 103 do 1 х 106 jtk/ml\nMetoda cytometrii przepływowej PB-03 wdanie 1/2013 data wydania 30.04.2013 r. w oparciu o instrukcję aparatu BactoScan FC Mleko surowe Ogolna liczba drobnoustrojow\nod 1 х 103 do 1 х 106 jtk/ml\nMetoda cytometrii przeplywowej PB-03 wdanie 1/2013 data wydania 30.04.2013 r. w oparciu o instrukcje aparatu BactoScan FC","categories":["food","microbiology"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","methodology_zh":"微生物总数","parameters_zh":[{"name":"1 х 103 至 1 х 106 cfu/ml"}],"search_zh":"生乳 微生物总数 流式细胞术 1 х 103 至 1 х 106 cfu/ml PB-03 wdanie 1/2013 data wydania 30.04.2013 r. w oparciu o instrukcję aparatu BactoScan FC","technique_zh":"流式细胞术","test_object_zh":"生乳","search_en":"Raw milk Total viable count Flow cytometry method from 1 х 103 to 1 х 106 CFU/ml PB-03 wdanie 1/2013 data wydania 30.04.2013 r. w oparciu o instrukcję aparatu BactoScan FC"},{"_id":"6a5dc9b3f1c10c8ce825c170","lab_id":"69ad52a3de79e566650fb247","country":"PL","accr_number":"AB 457","accr_body":"PCA","test_object":"Mleko surowe","test_object_en":"Raw milk","methodology":"Liczba komórek somatycznych","methodology_en":"Somatic cell count","parameters":[{"name":"od 1 х 103 do 1 х 106 komórek/ml"}],"parameters_en":[{"name":"from 1 х 103 to 1 х 106 cells/ml"}],"technique":"Metoda cytometrii przepływowej","techniques":["Metoda cytometrii przepływowej"],"technique_en":"Flow cytometry method","computed":[],"computed_en":[],"activity":"Liczba komórek somatycznych\nod 1 х 103 do 1 х 106 komórek/ml\nMetoda cytometrii przepływowej","reference":"PN-EN ISO 13366-2:2007 z zastosowaniem aparatu Fossomatic 5000","norm_bases":["PN-EN ISO 13366-2:2007 z zastosowaniem aparatu Fossomatic 5000"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mleko surowe Liczba komórek somatycznych\nod 1 х 103 do 1 х 106 komórek/ml\nMetoda cytometrii przepływowej PN-EN ISO 13366-2:2007 z zastosowaniem aparatu Fossomatic 5000 Mleko surowe Liczba komorek somatycznych\nod 1 х 103 do 1 х 106 komorek/ml\nMetoda cytometrii przeplywowej PN-EN ISO 13366-2:2007 z zastosowaniem aparatu Fossomatic 5000","categories":["food"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","methodology_zh":"体细胞计数","parameters_zh":[{"name":"1 х 103 至 1 х 106 细胞/ml"}],"search_zh":"生乳 体细胞计数 流式细胞术 1 х 103 至 1 х 106 细胞/ml PN-EN ISO 13366-2:2007 z zastosowaniem aparatu Fossomatic 5000","technique_zh":"流式细胞术","test_object_zh":"生乳","search_en":"Raw milk Somatic cell count Flow cytometry method from 1 х 103 to 1 х 106 cells/ml PN-EN ISO 13366-2:2007 z zastosowaniem aparatu Fossomatic 5000"},{"_id":"6a5dc9b3f1c10c8ce825c171","lab_id":"69ad52a3de79e566650fb247","country":"PL","accr_number":"AB 457","accr_body":"PCA","test_object":"Mleko surowe","test_object_en":"Raw milk","methodology":"Zawartość tłuszczu","methodology_en":"Fat content","parameters":[{"name":"Zakres","range":"(2,0 – 7,0)%"}],"parameters_en":[{"name":"Range","range":"(2,0 – 7,0)%"}],"technique":"Metoda spektrometrii w podczerwieni","techniques":["Metoda spektrometrii w podczerwieni"],"technique_en":"Infrared spectrometry method","computed":[],"computed_en":[],"activity":"Zawartość tłuszczu\nZakres (2,0 – 7,0)%\nMetoda spektrometrii w podczerwieni","reference":"PN-ISO 9622:2015-09 z zastosowaniem aparatu Milkoscan 4000","norm_bases":["PN-ISO 9622:2015-09 z zastosowaniem aparatu Milkoscan 4000"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mleko surowe Zawartość tłuszczu\nZakres (2,0 – 7,0)%\nMetoda spektrometrii w podczerwieni PN-ISO 9622:2015-09 z zastosowaniem aparatu Milkoscan 4000 Mleko surowe Zawartosc tluszczu\nZakres (2,0 – 7,0)%\nMetoda spektrometrii w podczerwieni PN-ISO 9622:2015-09 z zastosowaniem aparatu Milkoscan 4000","categories":["food"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","methodology_zh":"脂肪含量","parameters_zh":[{"name":"范围","range":"(2,0 – 7,0)%"}],"search_zh":"生乳 脂肪含量 红外光谱法 范围 PN-ISO 9622:2015-09 z zastosowaniem aparatu Milkoscan 4000","technique_zh":"红外光谱法","test_object_zh":"生乳","search_en":"Raw milk Fat content Infrared spectrometry method Range PN-ISO 9622:2015-09 z zastosowaniem aparatu Milkoscan 4000"},{"_id":"6a5dc9b3f1c10c8ce825c172","lab_id":"69ad52a3de79e566650fb247","country":"PL","accr_number":"AB 457","accr_body":"PCA","test_object":"Mleko surowe","test_object_en":"Raw milk","methodology":"Zawartość białka","methodology_en":"Protein content","parameters":[{"name":"Zakres","range":"(2,0 – 5,0) %"}],"parameters_en":[{"name":"Range","range":"(2,0 – 5,0) %"}],"technique":"Metoda spektrometrii w podczerwieni","techniques":["Metoda spektrometrii w podczerwieni"],"technique_en":"Infrared spectrometry method","computed":[],"computed_en":[],"activity":"Zawartość białka\nZakres (2,0 – 5,0) %\nMetoda spektrometrii w podczerwieni","reference":"PN-ISO 9622:2015-09 z zastosowaniem aparatu Milkoscan 4000","norm_bases":["PN-ISO 9622:2015-09 z zastosowaniem aparatu Milkoscan 4000"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mleko surowe Zawartość białka\nZakres (2,0 – 5,0) %\nMetoda spektrometrii w podczerwieni PN-ISO 9622:2015-09 z zastosowaniem aparatu Milkoscan 4000 Mleko surowe Zawartosc bialka\nZakres (2,0 – 5,0) %\nMetoda spektrometrii w podczerwieni PN-ISO 9622:2015-09 z zastosowaniem aparatu Milkoscan 4000","categories":["food"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","methodology_zh":"蛋白质含量","parameters_zh":[{"name":"范围","range":"(2,0 – 5,0) %"}],"search_zh":"生乳 蛋白质含量 红外光谱法 范围 PN-ISO 9622:2015-09 z zastosowaniem aparatu Milkoscan 4000","technique_zh":"红外光谱法","test_object_zh":"生乳","search_en":"Raw milk Protein content Infrared spectrometry method Range PN-ISO 9622:2015-09 z zastosowaniem aparatu Milkoscan 4000"},{"_id":"6a5dc9b3f1c10c8ce825c173","lab_id":"69ad52a3de79e566650fb247","country":"PL","accr_number":"AB 457","accr_body":"PCA","test_object":"Mleko surowe","test_object_en":"Raw milk","methodology":"Obecność antybiotyków i innych substancji hamujących","methodology_en":"Presence of antibiotics and other inhibitory substances","parameters":[],"parameters_en":[],"technique":"Metoda dyfuzyjna","techniques":["Metoda dyfuzyjna"],"technique_en":"Diffusion method","computed":[],"computed_en":[],"activity":"Obecność antybiotyków i innych substancji hamujących\nMetoda dyfuzyjna","reference":"PB-10/1 wydanie 1 Data wydania 04.08.2025 r. w oparciu o instrukcję producenta testu BRT MRL Screening Test","norm_bases":["PB-10/1 wydanie 1 Data wydania 04.08.2025 r. w oparciu o instrukcję producenta testu BRT MRL Screening Test"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mleko surowe Obecność antybiotyków i innych substancji hamujących\nMetoda dyfuzyjna PB-10/1 wydanie 1 Data wydania 04.08.2025 r. w oparciu o instrukcję producenta testu BRT MRL Screening Test Mleko surowe Obecnosc antybiotykow i innych substancji hamujacych\nMetoda dyfuzyjna PB-10/1 wydanie 1 Data wydania 04.08.2025 r. w oparciu o instrukcje producenta testu BRT MRL Screening Test","categories":["food"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","methodology_zh":"抗生素及其他抑菌物质的检出","search_zh":"生乳 抗生素及其他抑菌物质的检出 扩散法 PB-10/1 wydanie 1 Data wydania 04.08.2025 r. w oparciu o instrukcję producenta testu BRT MRL Screening Test","technique_zh":"扩散法","test_object_zh":"生乳","search_en":"Raw milk Presence of antibiotics and other inhibitory substances Diffusion method PB-10/1 wydanie 1 Data wydania 04.08.2025 r. w oparciu o instrukcję producenta testu BRT MRL Screening Test"},{"_id":"6a5dc9b3f1c10c8ce825c174","lab_id":"69ad52a3de79e566650fb247","country":"PL","accr_number":"AB 457","accr_body":"PCA","test_object":"Mleko surowe","test_object_en":"Raw milk","methodology":"Obecność antybiotyków β-laktamowych i tetracyklin","methodology_en":"Presence of β-lactam antibiotics and tetracyclines","parameters":[],"parameters_en":[],"technique":"Metoda receptorowa","techniques":["Metoda receptorowa"],"technique_en":"Receptor method","computed":[],"computed_en":[],"activity":"Obecność antybiotyków β-laktamowych i tetracyklin\nMetoda receptorowa","reference":"PB-10/2 wydanie 1 Data wydania 04.08.2025 r. w oparciu o instrukcję producenta testu MilkSafeTM 3BTC/BOX","norm_bases":["PB-10/2 wydanie 1 Data wydania 04.08.2025 r. w oparciu o instrukcję producenta testu MilkSafeTM 3BTC/BOX"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mleko surowe Obecność antybiotyków β-laktamowych i tetracyklin\nMetoda receptorowa PB-10/2 wydanie 1 Data wydania 04.08.2025 r. w oparciu o instrukcję producenta testu MilkSafeTM 3BTC/BOX Mleko surowe Obecnosc antybiotykow β-laktamowych i tetracyklin\nMetoda receptorowa PB-10/2 wydanie 1 Data wydania 04.08.2025 r. w oparciu o instrukcje producenta testu MilkSafeTM 3BTC/BOX","categories":["food"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","methodology_zh":"β-内酰胺类抗生素与四环素类的检出","search_zh":"生乳 β-内酰胺类抗生素与四环素类的检出 受体法 PB-10/2 wydanie 1 Data wydania 04.08.2025 r. w oparciu o instrukcję producenta testu MilkSafeTM 3BTC/BOX","technique_zh":"受体法","test_object_zh":"生乳","search_en":"Raw milk Presence of β-lactam antibiotics and tetracyclines Receptor method PB-10/2 wydanie 1 Data wydania 04.08.2025 r. w oparciu o instrukcję producenta testu MilkSafeTM 3BTC/BOX"}],"has_pdf":true}