{"lab":{"_id":"69ad52a3de79e566650fb23f","accr_number":"AB 450","country":"PL","accr_body":"PCA","address":"PRACOWNIA DAWEK INDYWIDUALNYCH I ŚRODOWISKOWYCH, ul. Konwaliowa 7, 03-194 Warszawa","categories":["environment","water"],"city":"Warszawa","imported_at":"2026-03-08T10:42:43.265Z","methods_count":9,"name":"CENTRALNE LABORATORIUM OCHRONY RADIOLOGICZNEJ","parse_status":"parsed","parse_version":2,"pdf_files":["AB_450.pdf"],"scope_summary":"","search_text":"centralne laboratorium ochrony radiologicznej pracownia dawek indywidualnych i środowiskowych, ul. konwaliowa 7, 03-194 warszawa other water environment","status":"active","updated_at":"2026-03-08T14:51:17.663Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:17.663Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20450,podmiot.html","fields_of_testing":[{"codes":"O/3, O/9, O/17, O/28","pl":"Badania radiochemiczne i promieniowania – w tym nuklearne w obiektach i materiałach biologicznych przeznaczonych do badań, wody, powietrza, wyrobów innych – dawkomierzy","en":"Radiochemical tests and tests of radiation – including nuclear radiation of biological items and materials for testing, water, air, other products - dosimeters"}],"issue":{"no":"20","date":"04.10.2024"},"parse_date":"2026-07-20T07:09:38.855Z","parse_source":"script-pdfplumber","map_coord":[52.30129,20.986425],"map_geo":"nominatim-street","has_en":true,"category_counts":{"other":5,"environment":3,"water":1},"category_scores":{"other":2.78,"environment":1,"water":0.11},"has_zh":true},"methods":[{"_id":"6a5dc9b2f1c10c8ce825bfd7","lab_id":"69ad52a3de79e566650fb23f","country":"PL","accr_number":"AB 450","accr_body":"PCA","test_object":"Dawkomierze w polu promieniowania jonizującego","test_object_en":"Dosimeters in an ionising radiation field","methodology":"Indywidualny równoważnik dawki Hp(10)","methodology_en":"Personal dose equivalent Hp(10)","parameters":[{"name":"Zakres","range":"0,1 mSv − 1 Sv"},{"name":"Zakres energii: promieniowanie rentgenowskie 33 keV – 250 keV promieniowanie gamma 50 keV – 1250 keV promieniowanie beta powyżej 0,5 MeV"}],"parameters_en":[{"name":"Range","range":"0,1 mSv − 1 Sv"},{"name":"Energy range: X-radiation 33 keV – 250 keV gamma radiation 50 keV – 1250 keV beta radiation above 0,5 MeV"}],"technique":"Metoda dozymetrii termoluminescencyjnej (TLD)","techniques":["Metoda dozymetrii termoluminescencyjnej (TLD)"],"technique_en":"Thermoluminescence dosimetry method (TLD)","computed":[],"computed_en":[],"activity":"Indywidualny równoważnik dawki Hp(10)\nZakres:\nZakres 0,1 mSv − 1 Sv\nZakres energii: promieniowanie rentgenowskie 33 keV – 250 keV promieniowanie gamma 50 keV – 1250 keV promieniowanie beta powyżej 0,5 MeV\nMetoda dozymetrii termoluminescencyjnej (TLD)","reference":"Procedura badawcza: PB-3T wydanie 2 z dnia 02.04.2024 r.","norm_bases":["Procedura badawcza: PB-3T wydanie 2 z dnia 02.04.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Dawkomierze w polu promieniowania jonizującego Indywidualny równoważnik dawki Hp(10)\nZakres:\nZakres 0,1 mSv − 1 Sv\nZakres energii: promieniowanie rentgenowskie 33 keV – 250 keV promieniowanie gamma 50 keV – 1250 keV promieniowanie beta powyżej 0,5 MeV\nMetoda dozymetrii termoluminescencyjnej (TLD) Procedura badawcza: PB-3T wydanie 2 z dnia 02.04.2024 r. Dawkomierze w polu promieniowania jonizujacego Indywidualny rownowaznik dawki Hp(10)\nZakres:\nZakres 0,1 mSv − 1 Sv\nZakres energii: promieniowanie rentgenowskie 33 keV – 250 keV promieniowanie gamma 50 keV – 1250 keV promieniowanie beta powyzej 0,5 MeV\nMetoda dozymetrii termoluminescencyjnej (TLD) Procedura badawcza: PB-3T wydanie 2 z dnia 02.04.2024 r.","categories":["other"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Dosimeters in an ionising radiation field Personal dose equivalent Hp(10) Thermoluminescence dosimetry method (TLD) Range Energy range: X-radiation 33 keV – 250 keV gamma radiation 50 keV – 1250 keV beta radiation above 0,5 MeV Procedura badawcza: PB-3T wydanie 2 z dnia 02.04.2024 r.","parameters_zh":[{"name":"范围","range":"0,1 mSv − 1 Sv"},{"name":"Zakres energii: promieniowanie rentgenowskie 33 keV – 250 keV promieniowanie gamma 50 keV – 1250 keV promieniowanie beta powyżej 0,5 MeV"}],"search_zh":"电离辐射场中的剂量计 热释光剂量测定法（TLD） 范围 Procedura badawcza: PB-3T wydanie 2 z dnia 02.04.2024 r.","test_object_zh":"电离辐射场中的剂量计","technique_zh":"热释光剂量测定法（TLD）"},{"_id":"6a5dc9b2f1c10c8ce825bfd8","lab_id":"69ad52a3de79e566650fb23f","country":"PL","accr_number":"AB 450","accr_body":"PCA","test_object":"Dawkomierze w polu promieniowania jonizującego","test_object_en":"Dosimeters in an ionising radiation field","methodology":"Indywidualny równoważnik dawki Hp(0,07)","methodology_en":"Personal dose equivalent Hp(0,07)","parameters":[{"name":"Zakres","range":"0,1 mSv − 1 Sv"},{"name":"Zakres energii: promieniowanie rentgenowskie 33 keV – 250 keV promieniowanie gamma 50 keV – 1250 keV promieniowanie beta powyżej 0,5 MeV"}],"parameters_en":[{"name":"Range","range":"0,1 mSv − 1 Sv"},{"name":"Energy range: X-radiation 33 keV – 250 keV gamma radiation 50 keV – 1250 keV beta radiation above 0,5 MeV"}],"technique":"Metoda dozymetrii termoluminescencyjnej (TLD)","techniques":["Metoda dozymetrii termoluminescencyjnej (TLD)"],"technique_en":"Thermoluminescence dosimetry method (TLD)","computed":[],"computed_en":[],"activity":"Indywidualny równoważnik dawki Hp(0,07)\nZakres:\nZakres 0,1 mSv − 1 Sv\nZakres energii: promieniowanie rentgenowskie 33 keV – 250 keV promieniowanie gamma 50 keV – 1250 keV promieniowanie beta powyżej 0,5 MeV\nMetoda dozymetrii termoluminescencyjnej (TLD)","reference":"Procedura badawcza: PB-3T wydanie 2 z dnia 02.04.2024 r.","norm_bases":["Procedura badawcza: PB-3T wydanie 2 z dnia 02.04.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Dawkomierze w polu promieniowania jonizującego Indywidualny równoważnik dawki Hp(0,07)\nZakres:\nZakres 0,1 mSv − 1 Sv\nZakres energii: promieniowanie rentgenowskie 33 keV – 250 keV promieniowanie gamma 50 keV – 1250 keV promieniowanie beta powyżej 0,5 MeV\nMetoda dozymetrii termoluminescencyjnej (TLD) Procedura badawcza: PB-3T wydanie 2 z dnia 02.04.2024 r. Dawkomierze w polu promieniowania jonizujacego Indywidualny rownowaznik dawki Hp(0,07)\nZakres:\nZakres 0,1 mSv − 1 Sv\nZakres energii: promieniowanie rentgenowskie 33 keV – 250 keV promieniowanie gamma 50 keV – 1250 keV promieniowanie beta powyzej 0,5 MeV\nMetoda dozymetrii termoluminescencyjnej (TLD) Procedura badawcza: PB-3T wydanie 2 z dnia 02.04.2024 r.","categories":["other"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Dosimeters in an ionising radiation field Personal dose equivalent Hp(0,07) Thermoluminescence dosimetry method (TLD) Range Energy range: X-radiation 33 keV – 250 keV gamma radiation 50 keV – 1250 keV beta radiation above 0,5 MeV Procedura badawcza: PB-3T wydanie 2 z dnia 02.04.2024 r.","parameters_zh":[{"name":"范围","range":"0,1 mSv − 1 Sv"},{"name":"Zakres energii: promieniowanie rentgenowskie 33 keV – 250 keV promieniowanie gamma 50 keV – 1250 keV promieniowanie beta powyżej 0,5 MeV"}],"search_zh":"电离辐射场中的剂量计 热释光剂量测定法（TLD） 范围 Procedura badawcza: PB-3T wydanie 2 z dnia 02.04.2024 r.","test_object_zh":"电离辐射场中的剂量计","technique_zh":"热释光剂量测定法（TLD）"},{"_id":"6a5dc9b2f1c10c8ce825bfd9","lab_id":"69ad52a3de79e566650fb23f","country":"PL","accr_number":"AB 450","accr_body":"PCA","test_object":"Dawkomierze w polu promieniowania jonizującego","test_object_en":"Dosimeters in an ionising radiation field","methodology":"Przestrzenny równoważnik dawki H*(10)","methodology_en":"Ambient dose equivalent H*(10)","parameters":[{"name":"Zakres","range":"0,1 mSv − 1 Sv"},{"name":"Zakres energii: promieniowanie rentgenowskie 33 keV – 250 keV promieniowanie gamma 50 keV – 1250 keV promieniowanie beta powyżej 0,5 MeV"}],"parameters_en":[{"name":"Range","range":"0,1 mSv − 1 Sv"},{"name":"Energy range: X-radiation 33 keV – 250 keV gamma radiation 50 keV – 1250 keV beta radiation above 0,5 MeV"}],"technique":"Metoda dozymetrii termoluminescencyjnej (TLD)","techniques":["Metoda dozymetrii termoluminescencyjnej (TLD)"],"technique_en":"Thermoluminescence dosimetry method (TLD)","computed":[],"computed_en":[],"activity":"Przestrzenny równoważnik dawki H*(10)\nZakres:\nZakres 0,1 mSv − 1 Sv\nZakres energii: promieniowanie rentgenowskie 33 keV – 250 keV promieniowanie gamma 50 keV – 1250 keV promieniowanie beta powyżej 0,5 MeV\nMetoda dozymetrii termoluminescencyjnej (TLD)","reference":"Procedura badawcza: PB-3T wydanie 2 z dnia 02.04.2024 r.","norm_bases":["Procedura badawcza: PB-3T wydanie 2 z dnia 02.04.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Dawkomierze w polu promieniowania jonizującego Przestrzenny równoważnik dawki H*(10)\nZakres:\nZakres 0,1 mSv − 1 Sv\nZakres energii: promieniowanie rentgenowskie 33 keV – 250 keV promieniowanie gamma 50 keV – 1250 keV promieniowanie beta powyżej 0,5 MeV\nMetoda dozymetrii termoluminescencyjnej (TLD) Procedura badawcza: PB-3T wydanie 2 z dnia 02.04.2024 r. Dawkomierze w polu promieniowania jonizujacego Przestrzenny rownowaznik dawki H*(10)\nZakres:\nZakres 0,1 mSv − 1 Sv\nZakres energii: promieniowanie rentgenowskie 33 keV – 250 keV promieniowanie gamma 50 keV – 1250 keV promieniowanie beta powyzej 0,5 MeV\nMetoda dozymetrii termoluminescencyjnej (TLD) Procedura badawcza: PB-3T wydanie 2 z dnia 02.04.2024 r.","categories":["other"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Dosimeters in an ionising radiation field Ambient dose equivalent H*(10) Thermoluminescence dosimetry method (TLD) Range Energy range: X-radiation 33 keV – 250 keV gamma radiation 50 keV – 1250 keV beta radiation above 0,5 MeV Procedura badawcza: PB-3T wydanie 2 z dnia 02.04.2024 r.","parameters_zh":[{"name":"范围","range":"0,1 mSv − 1 Sv"},{"name":"Zakres energii: promieniowanie rentgenowskie 33 keV – 250 keV promieniowanie gamma 50 keV – 1250 keV promieniowanie beta powyżej 0,5 MeV"}],"search_zh":"电离辐射场中的剂量计 热释光剂量测定法（TLD） 范围 Procedura badawcza: PB-3T wydanie 2 z dnia 02.04.2024 r.","test_object_zh":"电离辐射场中的剂量计","technique_zh":"热释光剂量测定法（TLD）"},{"_id":"6a5dc9b2f1c10c8ce825bfda","lab_id":"69ad52a3de79e566650fb23f","country":"PL","accr_number":"AB 450","accr_body":"PCA","test_object":"Dawkomierze w polu promieniowania jonizującego","test_object_en":"Dosimeters in an ionising radiation field","methodology":"Indywidualny równoważnik dawki Hp(3)","methodology_en":"Personal dose equivalent Hp(3)","parameters":[{"name":"Zakres","range":"0,1 mSv − 1 Sv"}],"parameters_en":[{"name":"Range","range":"0,1 mSv − 1 Sv"}],"technique":"Metoda dozymetrii termoluminescencyjnej (TLD)","techniques":["Metoda dozymetrii termoluminescencyjnej (TLD)"],"technique_en":"Thermoluminescence dosimetry method (TLD)","computed":[],"computed_en":[],"activity":"Indywidualny równoważnik dawki Hp(3)\nZakres 0,1 mSv − 1 Sv\nMetoda dozymetrii termoluminescencyjnej (TLD)","reference":"Procedura badawcza: PB-3T wydanie 2 z dnia 02.04.2024 r.","norm_bases":["Procedura badawcza: PB-3T wydanie 2 z dnia 02.04.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Dawkomierze w polu promieniowania jonizującego Indywidualny równoważnik dawki Hp(3)\nZakres 0,1 mSv − 1 Sv\nMetoda dozymetrii termoluminescencyjnej (TLD) Procedura badawcza: PB-3T wydanie 2 z dnia 02.04.2024 r. Dawkomierze w polu promieniowania jonizujacego Indywidualny rownowaznik dawki Hp(3)\nZakres 0,1 mSv − 1 Sv\nMetoda dozymetrii termoluminescencyjnej (TLD) Procedura badawcza: PB-3T wydanie 2 z dnia 02.04.2024 r.","categories":["other"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Dosimeters in an ionising radiation field Personal dose equivalent Hp(3) Thermoluminescence dosimetry method (TLD) Range Procedura badawcza: PB-3T wydanie 2 z dnia 02.04.2024 r.","parameters_zh":[{"name":"范围","range":"0,1 mSv − 1 Sv"}],"search_zh":"电离辐射场中的剂量计 热释光剂量测定法（TLD） 范围 Procedura badawcza: PB-3T wydanie 2 z dnia 02.04.2024 r.","test_object_zh":"电离辐射场中的剂量计","technique_zh":"热释光剂量测定法（TLD）"},{"_id":"6a5dc9b2f1c10c8ce825bfdb","lab_id":"69ad52a3de79e566650fb23f","country":"PL","accr_number":"AB 450","accr_body":"PCA","test_object":"Tarczyca człowieka","test_object_en":"Human thyroid","methodology":"Aktywność jodu promieniotwórczego 131I zdeponowanego w tarczycy człowieka","methodology_en":"Activity of radioactive iodine 131I deposited in the human thyroid","parameters":[{"name":"Zakres","range":"60 Bq − 5 MBq"}],"parameters_en":[{"name":"Range","range":"60 Bq − 5 MBq"}],"technique":"Metoda spektrometrii promieniowania gamma","techniques":["Metoda spektrometrii promieniowania gamma"],"technique_en":"Gamma-ray spectrometry method","computed":[],"computed_en":[],"activity":"Aktywność jodu promieniotwórczego 131I zdeponowanego w tarczycy człowieka\nZakres 60 Bq − 5 MBq\nMetoda spektrometrii promieniowania gamma","reference":"Procedura badawcza PB-4J wydanie 1 z dnia 10.06.2021 r.","norm_bases":["Procedura badawcza PB-4J wydanie 1 z dnia 10.06.2021 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Tarczyca człowieka Aktywność jodu promieniotwórczego 131I zdeponowanego w tarczycy człowieka\nZakres 60 Bq − 5 MBq\nMetoda spektrometrii promieniowania gamma Procedura badawcza PB-4J wydanie 1 z dnia 10.06.2021 r. Tarczyca czlowieka Aktywnosc jodu promieniotworczego 131I zdeponowanego w tarczycy czlowieka\nZakres 60 Bq − 5 MBq\nMetoda spektrometrii promieniowania gamma Procedura badawcza PB-4J wydanie 1 z dnia 10.06.2021 r.","categories":["other"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Human thyroid Activity of radioactive iodine 131I deposited in the human thyroid Gamma-ray spectrometry method Range Procedura badawcza PB-4J wydanie 1 z dnia 10.06.2021 r.","parameters_zh":[{"name":"范围","range":"60 Bq − 5 MBq"}],"search_zh":"γ 能谱法 范围 Procedura badawcza PB-4J wydanie 1 z dnia 10.06.2021 r.","technique_zh":"γ 能谱法"},{"_id":"6a5dc9b2f1c10c8ce825bfdc","lab_id":"69ad52a3de79e566650fb23f","country":"PL","accr_number":"AB 450","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie izotopu radonu 222Rn","methodology_en":"Concentration of the radon isotope 222Rn","parameters":[{"name":"Zakres","range":"6 Bq/dm3 – 4 kBq/dm3"}],"parameters_en":[{"name":"Range","range":"6 Bq/dm3 – 4 kBq/dm3"}],"technique":"Metoda spektrometrii promieniowania alfa","techniques":["Metoda spektrometrii promieniowania alfa"],"technique_en":"Alpha spectrometry method","computed":[],"computed_en":[],"activity":"Stężenie izotopu radonu 222Rn\nZakres 6 Bq/dm3 – 4 kBq/dm3\nMetoda spektrometrii promieniowania alfa","reference":"Procedura badawcza: PB-1W wydanie 1 z dnia 10.06.2021 r.","norm_bases":["Procedura badawcza: PB-1W wydanie 1 z dnia 10.06.2021 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie izotopu radonu 222Rn\nZakres 6 Bq/dm3 – 4 kBq/dm3\nMetoda spektrometrii promieniowania alfa Procedura badawcza: PB-1W wydanie 1 z dnia 10.06.2021 r. Woda Stezenie izotopu radonu 222Rn\nZakres 6 Bq/dm3 – 4 kBq/dm3\nMetoda spektrometrii promieniowania alfa Procedura badawcza: PB-1W wydanie 1 z dnia 10.06.2021 r.","categories":["water"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Concentration of the radon isotope 222Rn Alpha spectrometry method Range Procedura badawcza: PB-1W wydanie 1 z dnia 10.06.2021 r.","parameters_zh":[{"name":"范围","range":"6 Bq/dm3 – 4 kBq/dm3"}],"search_zh":"水 α 能谱法 范围 Procedura badawcza: PB-1W wydanie 1 z dnia 10.06.2021 r.","test_object_zh":"水","technique_zh":"α 能谱法"},{"_id":"6a5dc9b2f1c10c8ce825bfdd","lab_id":"69ad52a3de79e566650fb23f","country":"PL","accr_number":"AB 450","accr_body":"PCA","test_object":"Powietrze","test_object_en":"Air","methodology":"Stężenie izotopu radonu 222Rn, Zakres dla dowolnego czasu ekspozycji detektora: 20 kBq*h/m3 – 10 000 kBq*h/m3 podzielony przez czas ekspozycji detektora wyrażony w godzinach","methodology_en":"Radon isotope 222Rn concentration, Range for any detector exposure time: 20 kBq*h/m3 – 10 000 kBq*h/m3 divided by the detector exposure time expressed in hours","parameters":[],"parameters_en":[],"technique":"Metoda detektorów śladowych","techniques":["Metoda detektorów śladowych"],"technique_en":"Track detector method","computed":[],"computed_en":[],"activity":"Stężenie izotopu radonu 222Rn, Zakres dla dowolnego czasu ekspozycji detektora: 20 kBq*h/m3 – 10 000 kBq*h/m3 podzielony przez czas ekspozycji detektora wyrażony w godzinach\nMetoda detektorów śladowych","reference":"Procedura badawcza: PB-2P Wydanie 3 z dnia 01.07.2024 r.","norm_bases":["Procedura badawcza: PB-2P Wydanie 3 z dnia 01.07.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Powietrze Stężenie izotopu radonu 222Rn, Zakres dla dowolnego czasu ekspozycji detektora: 20 kBq*h/m3 – 10 000 kBq*h/m3 podzielony przez czas ekspozycji detektora wyrażony w godzinach\nMetoda detektorów śladowych Procedura badawcza: PB-2P Wydanie 3 z dnia 01.07.2024 r. Powietrze Stezenie izotopu radonu 222Rn, Zakres dla dowolnego czasu ekspozycji detektora: 20 kBq*h/m3 – 10 000 kBq*h/m3 podzielony przez czas ekspozycji detektora wyrazony w godzinach\nMetoda detektorow sladowych Procedura badawcza: PB-2P Wydanie 3 z dnia 01.07.2024 r.","categories":["environment"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Air Radon isotope 222Rn concentration, Range for any detector exposure time: 20 kBq*h/m3 – 10 000 kBq*h/m3 divided by the detector exposure time expressed in hours Track detector method Procedura badawcza: PB-2P Wydanie 3 z dnia 01.07.2024 r.","search_zh":"空气 径迹探测器法 Procedura badawcza: PB-2P Wydanie 3 z dnia 01.07.2024 r.","test_object_zh":"空气","technique_zh":"径迹探测器法"},{"_id":"6a5dc9b2f1c10c8ce825bfde","lab_id":"69ad52a3de79e566650fb23f","country":"PL","accr_number":"AB 450","accr_body":"PCA","test_object":"Powietrze","test_object_en":"Air","methodology":"Średnioroczne stężenie radonu (z obliczeń)","methodology_en":"Annual average radon concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Średnioroczne stężenie radonu (z obliczeń)","reference":"Procedura badawcza: PB-2P Wydanie 3 z dnia 01.07.2024 r.","norm_bases":["Procedura badawcza: PB-2P Wydanie 3 z dnia 01.07.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Powietrze Średnioroczne stężenie radonu (z obliczeń) Procedura badawcza: PB-2P Wydanie 3 z dnia 01.07.2024 r. Powietrze Srednioroczne stezenie radonu (z obliczen) Procedura badawcza: PB-2P Wydanie 3 z dnia 01.07.2024 r.","categories":["environment"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Air Annual average radon concentration (calculated) Procedura badawcza: PB-2P Wydanie 3 z dnia 01.07.2024 r.","search_zh":"空气 Procedura badawcza: PB-2P Wydanie 3 z dnia 01.07.2024 r.","test_object_zh":"空气"},{"_id":"6a5dc9b2f1c10c8ce825bfdf","lab_id":"69ad52a3de79e566650fb23f","country":"PL","accr_number":"AB 450","accr_body":"PCA","test_object":"Powietrze","test_object_en":"Air","methodology":"Obciążająca dawka skuteczna (efektywna) (z obliczeń)","methodology_en":"Committed effective dose (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Obciążająca dawka skuteczna (efektywna) (z obliczeń)","reference":"Procedura badawcza: PB-2P Wydanie 3 z dnia 01.07.2024 r.","norm_bases":["Procedura badawcza: PB-2P Wydanie 3 z dnia 01.07.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Powietrze Obciążająca dawka skuteczna (efektywna) (z obliczeń) Procedura badawcza: PB-2P Wydanie 3 z dnia 01.07.2024 r. Powietrze Obciazajaca dawka skuteczna (efektywna) (z obliczen) Procedura badawcza: PB-2P Wydanie 3 z dnia 01.07.2024 r.","categories":["environment"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Air Committed effective dose (calculated) Procedura badawcza: PB-2P Wydanie 3 z dnia 01.07.2024 r.","search_zh":"空气 Procedura badawcza: PB-2P Wydanie 3 z dnia 01.07.2024 r.","test_object_zh":"空气"}],"has_pdf":true}