{"lab":{"_id":"69ad52a3de79e566650fb23b","accr_number":"AB 447","country":"PL","accr_body":"PCA","address":"ul. Chmielna 132/134, 00-805 Warszawa, CENTRALNE LABORATORIUM BADAWCZE, ODDZIAŁ W RZESZOWIE","categories":["water","environment","materials"],"city":"Warszawa","imported_at":"2026-03-08T10:42:43.265Z","methods_count":124,"name":"GŁÓWNY INSPEKTORAT OCHRONY ŚRODOWISKA","parse_status":"parsed","parse_version":3,"pdf_files":["AB_447.pdf"],"scope_summary":"","search_text":"główny inspektorat ochrony środowiska ul. chmielna 132/134, 00-805 warszawa, centralne laboratorium badawcze, oddział w rzeszowie water other pharma electronics environment metrology food materials automotive microbiology petro","status":"active","updated_at":"2026-03-08T14:51:17.484Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-17T20:25:24.483Z","location":{"type":"Point","coordinates":[21.0122,52.2297]},"email_confidence":"high","email_mx":true,"email_source":"https://www.gov.pl/web/gios/centralne-laboratorium-badawcze","fields_of_testing":[{"codes":"B/31/P, B/32/P","pl":"Badania biologiczne i pobieranie próbek gleby, odpadów, osadów","en":"Biological tests and sampling of soil, waste, sediments"},{"codes":"C/28/P, C/30/P, C/31/P, C/32/P","pl":"Badania chemiczne i pobieranie próbek: wody, ścieków, gleby, osadów, odpadów","en":"Chemical tests and sampling of water, sewage, soil, sediments, waste"},{"codes":"G/34","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko ogólne (czynniki fizyczne – hałas, pole elektromagnetyczne)","en":"Tests concerning environmental engineering (environmental and climatic) – general environment (physical factors – noise, electromagnetic field)"},{"codes":"K/31, K/32","pl":"Badania mikrobiologiczne gleby, odpadów, osadów","en":"Microbiological tests of soil, waste, sediments"},{"codes":"N/28/P, N/30/P, N/31/P, N/32/P","pl":"Badania właściwości fizycznych i pobieranie próbek: wody, ścieków, gleby, osadów, odpadów","en":"Tests of physical properties and sampling of water, sewage, soil, sediments, waste"}],"issue":{"no":"29","date":"16.07.2026"},"parse_date":"2026-08-17T20:25:24.483Z","parse_source":"agent-claude-code","map_coord":[52.227738,20.992749],"map_geo":"nominatim-street","lab_locations":[{"name":"ODDZIAŁ W RZESZOWIE","address":"ul. Gen. M. Langiewicza 26","city":null,"postal":null},{"name":"Pracownia Terenowa","address":"ul. Gen. M. Langiewicza 26, 35-101 Rzeszów","city":"Rzeszów","postal":"35-101"},{"name":"Pracownia w Rzeszowie","address":"ul. Gen. M. Langiewicza 26, 35-101 Rzeszów","city":"Rzeszów","postal":"35-101"},{"name":"Pracownia w Jaśle","address":"ul. Floriańska 108, 38-200 Jasło","city":"Jasło","postal":"38-200"},{"name":"Pracownia w Przemyślu","address":"ul. Pl. Dominikański 3, 37-700 Przemyśl","city":"Przemyśl","postal":"37-700"}],"scope_format":"PCA::pracownie+siatka9","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/b7787d874fd82a3be88b10b21d4757ce/AB%20447.pdf","has_en":true,"category_counts":{"water":89,"environment":46,"materials":5,"petro":3,"microbiology":2,"other":1},"category_scores":{"water":54.25,"environment":14.49,"materials":0.17,"petro":0.06,"microbiology":0.03,"other":0.01},"has_zh":true},"methods":[{"_id":"6a836e34af14b9c0e7b1e830","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań fizycznych i chemicznych","parameters":[],"technique":"Metoda manualna; Metoda automatyczna","techniques":["Metoda manualna","Metoda automatyczna"],"computed":[],"activity":"Pobieranie próbek do badań fizycznych i chemicznych\nMetoda manualna; Metoda automatyczna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań fizycznych i chemicznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 Scieki Pobieranie probek do badan fizycznych i chemicznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for physical and chemical testing","search_en":"Wastewater Sampling for physical and chemical testing Manual method; Automatic method PN-ISO 5667-10:2021-11","technique_en":"Manual method; Automatic method","test_object_en":"Wastewater","methodology_zh":"物理与化学检测用样品采集","search_zh":"污水 物理与化学检测用样品采集 手动法；自动法 PN-ISO 5667-10:2021-11","technique_zh":"手动法；自动法","test_object_zh":"污水"},{"_id":"6a836e34af14b9c0e7b1e831","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Ścieki","methodology":"Temperatura","parameters":[{"name":"Zakres","range":"(-0,5) °C – (+50,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura\nZakres (-0,5) °C – (+50,0) °C","reference":"PN-77/C-04584","norm_bases":["PN-77/C-04584"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Temperatura\nZakres (-0,5) °C – (+50,0) °C PN-77/C-04584 Scieki Temperatura\nZakres (-0,5) °C – (+50,0) °C PN-77/C-04584","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Temperature","parameters_en":[{"name":"Range","range":"(-0,5) °C – (+50,0) °C"}],"search_en":"Wastewater Temperature Range PN-77/C-04584","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(-0,5) °C – (+50,0) °C"}],"search_zh":"污水 温度 范围 PN-77/C-04584","test_object_zh":"污水","methodology_zh":"温度"},{"_id":"6a836e34af14b9c0e7b1e832","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda","methodology":"Pobieranie próbek do badań fizycznych i chemicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań fizycznych i chemicznych","reference":"PN-ISO 5667-4:2017-10 | PN-EN ISO 5667-6:2016-12 | PN-ISO 5667-11:2017-10 z wył. p 5.2, 6.1.2, 6.2, 6.3","norm_bases":["PN-ISO 5667-4:2017-10","PN-EN ISO 5667-6:2016-12","PN-ISO 5667-11:2017-10 z wył. p 5.2, 6.1.2, 6.2, 6.3"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Pobieranie próbek do badań fizycznych i chemicznych PN-ISO 5667-4:2017-10 | PN-EN ISO 5667-6:2016-12 | PN-ISO 5667-11:2017-10 z wył. p 5.2, 6.1.2, 6.2, 6.3 Woda Pobieranie probek do badan fizycznych i chemicznych PN-ISO 5667-4:2017-10 | PN-EN ISO 5667-6:2016-12 | PN-ISO 5667-11:2017-10 z wyl. p 5.2, 6.1.2, 6.2, 6.3","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for physical and chemical testing","search_en":"Water Sampling for physical and chemical testing PN-ISO 5667-4:2017-10 | PN-EN ISO 5667-6:2016-12 | PN-ISO 5667-11:2017-10 z wył. p 5.2, 6.1.2, 6.2, 6.3","test_object_en":"Water","methodology_zh":"物理与化学检测用样品采集","search_zh":"水 物理与化学检测用样品采集 PN-ISO 5667-4:2017-10 | PN-EN ISO 5667-6:2016-12 | PN-ISO 5667-11:2017-10 z wył. p 5.2, 6.1.2, 6.2, 6.3","test_object_zh":"水"},{"_id":"6a836e34af14b9c0e7b1e833","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda","methodology":"Temperatura","parameters":[{"name":"Zakres","range":"(-0,5) °C – (+50,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura\nZakres (-0,5) °C – (+50,0) °C","reference":"PN-77/C-04584","norm_bases":["PN-77/C-04584"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Temperatura\nZakres (-0,5) °C – (+50,0) °C PN-77/C-04584 Woda Temperatura\nZakres (-0,5) °C – (+50,0) °C PN-77/C-04584","categories":["water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Temperature","parameters_en":[{"name":"Range","range":"(-0,5) °C – (+50,0) °C"}],"search_en":"Water Temperature Range PN-77/C-04584","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(-0,5) °C – (+50,0) °C"}],"search_zh":"水 温度 范围 PN-77/C-04584","test_object_zh":"水","methodology_zh":"温度"},{"_id":"6a836e34af14b9c0e7b1e834","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, scieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"search_en":"Water, wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water, wastewater","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"水、废水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、废水"},{"_id":"6a836e34af14b9c0e7b1e835","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(70 – 20 000) µS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (70 – 20 000) µS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Przewodność elektryczna właściwa\nZakres (70 – 20 000) µS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, scieki Przewodnosc elektryczna wlasciwa\nZakres (70 – 20 000) µS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(70 – 20 000) µS/cm"}],"search_en":"Water, wastewater Electrical conductivity Conductometric method Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water, wastewater","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(70 – 20 000) µS/cm"}],"search_zh":"水、废水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、废水"},{"_id":"6a836e34af14b9c0e7b1e836","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie tlenu rozpuszczonego","parameters":[{"name":"Zakres","range":"(0,5 – 15,0) mg/l O2"}],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie tlenu rozpuszczonego\nZakres (0,5 – 15,0) mg/l O2","reference":"PN-EN ISO 5814:2013-04","norm_bases":["PN-EN ISO 5814:2013-04"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie tlenu rozpuszczonego\nZakres (0,5 – 15,0) mg/l O2 PN-EN ISO 5814:2013-04 Woda Stezenie tlenu rozpuszczonego\nZakres (0,5 – 15,0) mg/l O2 PN-EN ISO 5814:2013-04","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissolved oxygen concentration","parameters_en":[{"name":"Range","range":"(0,5 – 15,0) mg/l O2"}],"search_en":"Water Dissolved oxygen concentration Range PN-EN ISO 5814:2013-04","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,5 – 15,0) mg/l O2"}],"search_zh":"水 溶解氧浓度 范围 PN-EN ISO 5814:2013-04","test_object_zh":"水","methodology_zh":"溶解氧浓度"},{"_id":"6a836e34af14b9c0e7b1e837","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda","methodology":"Nasycenie tlenem","parameters":[{"name":"Zakres","range":"(1 – 200) %"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Nasycenie tlenem\nZakres (1 – 200) %\nMetoda elektrochemiczna","reference":"PN-EN ISO 5814:2013-04","norm_bases":["PN-EN ISO 5814:2013-04"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Nasycenie tlenem\nZakres (1 – 200) %\nMetoda elektrochemiczna PN-EN ISO 5814:2013-04 Woda Nasycenie tlenem\nZakres (1 – 200) %\nMetoda elektrochemiczna PN-EN ISO 5814:2013-04","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Oxygen saturation","parameters_en":[{"name":"Range","range":"(1 – 200) %"}],"search_en":"Water Oxygen saturation Electrochemical method Range PN-EN ISO 5814:2013-04","technique_en":"Electrochemical method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(1 – 200) %"}],"search_zh":"水 氧饱和度 电化学法 范围 PN-EN ISO 5814:2013-04","technique_zh":"电化学法","test_object_zh":"水","methodology_zh":"氧饱和度"},{"_id":"6a836e34af14b9c0e7b1e838","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie tlenu rozpuszczonego","parameters":[{"name":"Zakres","range":"(0,5 - 15,0) mg/l O2"}],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie tlenu rozpuszczonego\nZakres (0,5 - 15,0) mg/l O2","reference":"ISO 17289:2014","norm_bases":["ISO 17289:2014"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie tlenu rozpuszczonego\nZakres (0,5 - 15,0) mg/l O2 ISO 17289:2014 Woda Stezenie tlenu rozpuszczonego\nZakres (0,5 - 15,0) mg/l O2 ISO 17289:2014","categories":["water"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissolved oxygen concentration","parameters_en":[{"name":"Range","range":"(0,5 - 15,0) mg/l O2"}],"search_en":"Water Dissolved oxygen concentration Range ISO 17289:2014","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,5 - 15,0) mg/l O2"}],"search_zh":"水 溶解氧浓度 范围 ISO 17289:2014","test_object_zh":"水","methodology_zh":"溶解氧浓度"},{"_id":"6a836e34af14b9c0e7b1e839","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda","methodology":"Nasycenie tlenem","parameters":[{"name":"Zakres","range":"(1 - 200) %"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Nasycenie tlenem\nZakres (1 - 200) %\nMetoda optyczna","reference":"ISO 17289:2014","norm_bases":["ISO 17289:2014"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Nasycenie tlenem\nZakres (1 - 200) %\nMetoda optyczna ISO 17289:2014 Woda Nasycenie tlenem\nZakres (1 - 200) %\nMetoda optyczna ISO 17289:2014","categories":["water"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Oxygen saturation","parameters_en":[{"name":"Range","range":"(1 - 200) %"}],"search_en":"Water Oxygen saturation Optical method Range ISO 17289:2014","technique_en":"Optical method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(1 - 200) %"}],"search_zh":"水 氧饱和度 光学法 范围 ISO 17289:2014","technique_zh":"光学法","test_object_zh":"水","methodology_zh":"氧饱和度"},{"_id":"6a836e34af14b9c0e7b1e83a","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Gleby","methodology":"Pobieranie próbek do badań fizycznych, chemicznych i biologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań fizycznych, chemicznych i biologicznych","reference":"PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009","norm_bases":["PN-ISO 10381-4:2007","PN-ISO 10381-5:2009"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleby Pobieranie próbek do badań fizycznych, chemicznych i biologicznych PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009 Gleby Pobieranie probek do badan fizycznych, chemicznych i biologicznych PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009","categories":["other"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for physical, chemical and biological testing","search_en":"Soils Sampling for physical, chemical and biological testing PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009","test_object_en":"Soils","search_zh":"土壤 PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009","test_object_zh":"土壤"},{"_id":"6a836e34af14b9c0e7b1e83b","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od dróg, linii kolejowych, linii tramwajowych","methodology":"Równoważny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(30,0 – 130,0) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A\nZakres (30,0 – 130,0) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. Nr 140 poz. 824, Dz.U. Nr 288 poz. 1697) z wyłączeniem punktu H","norm_bases":["Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. Nr 140 poz. 824, Dz.U. Nr 288 poz. 1697) z wyłączeniem punktu H"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – hałas pochodzący od dróg, linii kolejowych, linii tramwajowych Równoważny poziom dźwięku A\nZakres (30,0 – 130,0) dB\nMetoda pomiarowa bezpośrednia Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. Nr 140 poz. 824, Dz.U. Nr 288 poz. 1697) z wyłączeniem punktu H Srodowisko ogolne – halas pochodzacy od drog, linii kolejowych, linii tramwajowych Rownowazny poziom dzwieku A\nZakres (30,0 – 130,0) dB\nMetoda pomiarowa bezposrednia Zalacznik nr 3 do Rozporzadzenia Ministra Srodowiska z dnia 16.06.2011 r. (Dz. U. Nr 140 poz. 824, Dz.U. Nr 288 poz. 1697) z wylaczeniem punktu H","categories":["environment"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound pressure level","parameters_en":[{"name":"Range","range":"(30,0 – 130,0) dB"}],"search_en":"General environment – noise from roads, railway lines, tram lines A-weighted equivalent sound pressure level Direct measurement method Range Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. Nr 140 poz. 824, Dz.U. Nr 288 poz. 1697) z wyłączeniem punktu H","technique_en":"Direct measurement method","test_object_en":"General environment – noise from roads, railway lines, tram lines","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"范围","range":"(30,0 – 130,0) dB"}],"search_zh":"一般环境 — 来自道路、铁路线、有轨电车线的噪声 A 计权等效声级 直接测量法 范围 Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. Nr 140 poz. 824, Dz.U. Nr 288 poz. 1697) z wyłączeniem punktu H","technique_zh":"直接测量法","test_object_zh":"一般环境 — 来自道路、铁路线、有轨电车线的噪声"},{"_id":"6a836e34af14b9c0e7b1e83c","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od dróg, linii kolejowych, linii tramwajowych","methodology":"Ekspozycyjny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(30,0 – 130,0) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Ekspozycyjny poziom dźwięku A\nZakres (30,0 – 130,0) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. Nr 140 poz. 824, Dz.U. Nr 288 poz. 1697) z wyłączeniem punktu H","norm_bases":["Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. Nr 140 poz. 824, Dz.U. Nr 288 poz. 1697) z wyłączeniem punktu H"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – hałas pochodzący od dróg, linii kolejowych, linii tramwajowych Ekspozycyjny poziom dźwięku A\nZakres (30,0 – 130,0) dB\nMetoda pomiarowa bezpośrednia Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. Nr 140 poz. 824, Dz.U. Nr 288 poz. 1697) z wyłączeniem punktu H Srodowisko ogolne – halas pochodzacy od drog, linii kolejowych, linii tramwajowych Ekspozycyjny poziom dzwieku A\nZakres (30,0 – 130,0) dB\nMetoda pomiarowa bezposrednia Zalacznik nr 3 do Rozporzadzenia Ministra Srodowiska z dnia 16.06.2011 r. (Dz. U. Nr 140 poz. 824, Dz.U. Nr 288 poz. 1697) z wylaczeniem punktu H","categories":["environment"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted sound exposure level","parameters_en":[{"name":"Range","range":"(30,0 – 130,0) dB"}],"search_en":"General environment – noise from roads, railway lines, tram lines A-weighted sound exposure level Direct measurement method Range Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. Nr 140 poz. 824, Dz.U. Nr 288 poz. 1697) z wyłączeniem punktu H","technique_en":"Direct measurement method","test_object_en":"General environment – noise from roads, railway lines, tram lines","parameters_zh":[{"name":"范围","range":"(30,0 – 130,0) dB"}],"search_zh":"一般环境 — 来自道路、铁路线、有轨电车线的噪声 A 计权声暴露级 直接测量法 范围 Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. Nr 140 poz. 824, Dz.U. Nr 288 poz. 1697) z wyłączeniem punktu H","technique_zh":"直接测量法","test_object_zh":"一般环境 — 来自道路、铁路线、有轨电车线的噪声","methodology_zh":"A 计权声暴露级"},{"_id":"6a836e34af14b9c0e7b1e83d","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od dróg, linii kolejowych, linii tramwajowych","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. Nr 140 poz. 824, Dz.U. Nr 288 poz. 1697) z wyłączeniem punktu H","norm_bases":["Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. Nr 140 poz. 824, Dz.U. Nr 288 poz. 1697) z wyłączeniem punktu H"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – hałas pochodzący od dróg, linii kolejowych, linii tramwajowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. Nr 140 poz. 824, Dz.U. Nr 288 poz. 1697) z wyłączeniem punktu H Srodowisko ogolne – halas pochodzacy od drog, linii kolejowych, linii tramwajowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen) Zalacznik nr 3 do Rozporzadzenia Ministra Srodowiska z dnia 16.06.2011 r. (Dz. U. Nr 140 poz. 824, Dz.U. Nr 288 poz. 1697) z wylaczeniem punktu H","categories":["environment"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","search_en":"General environment – noise from roads, railway lines, tram lines A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. Nr 140 poz. 824, Dz.U. Nr 288 poz. 1697) z wyłączeniem punktu H","test_object_en":"General environment – noise from roads, railway lines, tram lines","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境 — 来自道路、铁路线、有轨电车线的噪声 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值） Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. Nr 140 poz. 824, Dz.U. Nr 288 poz. 1697) z wyłączeniem punktu H","test_object_zh":"一般环境 — 来自道路、铁路线、有轨电车线的噪声"},{"_id":"6a836e34af14b9c0e7b1e83e","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(30,0 – 130,0) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A\nZakres (30,0 – 130,0) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tekst jednolity Dz.U. 2023, poz. 1706) z wyłączeniem punktu F","norm_bases":["Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tekst jednolity Dz.U. 2023, poz. 1706) z wyłączeniem punktu F"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A\nZakres (30,0 – 130,0) dB\nMetoda pomiarowa bezpośrednia Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tekst jednolity Dz.U. 2023, poz. 1706) z wyłączeniem punktu F Srodowisko ogolne – halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A\nZakres (30,0 – 130,0) dB\nMetoda pomiarowa bezposrednia Zalacznik Nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (tekst jednolity Dz.U. 2023, poz. 1706) z wylaczeniem punktu F","categories":["environment"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound pressure level","parameters_en":[{"name":"Range","range":"(30,0 – 130,0) dB"}],"search_en":"General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level Direct measurement method Range Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tekst jednolity Dz.U. 2023, poz. 1706) z wyłączeniem punktu F","technique_en":"Direct measurement method","test_object_en":"General environment – noise from installations, equipment and industrial plants","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"范围","range":"(30,0 – 130,0) dB"}],"search_zh":"一般环境 – 来自设施、设备与工业企业的噪声 A 计权等效声级 直接测量法 范围 Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tekst jednolity Dz.U. 2023, poz. 1706) z wyłączeniem punktu F","technique_zh":"直接测量法","test_object_zh":"一般环境 – 来自设施、设备与工业企业的噪声"},{"_id":"6a836e34af14b9c0e7b1e83f","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tekst jednolity Dz.U. 2023, poz. 1706) z wyłączeniem punktu F","norm_bases":["Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tekst jednolity Dz.U. 2023, poz. 1706) z wyłączeniem punktu F"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tekst jednolity Dz.U. 2023, poz. 1706) z wyłączeniem punktu F Srodowisko ogolne – halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen) Zalacznik Nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (tekst jednolity Dz.U. 2023, poz. 1706) z wylaczeniem punktu F","categories":["environment"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","search_en":"General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tekst jednolity Dz.U. 2023, poz. 1706) z wyłączeniem punktu F","test_object_en":"General environment – noise from installations, equipment and industrial plants","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境 – 来自设施、设备与工业企业的噪声 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值） Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tekst jednolity Dz.U. 2023, poz. 1706) z wyłączeniem punktu F","test_object_zh":"一般环境 – 来自设施、设备与工业企业的噪声"},{"_id":"6a836e34af14b9c0e7b1e840","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Odpady O) : kod 01 04 09 10 01 01 , 10 01 02, 10 01 03, 10 02 02, 10 09 03, 10 12 03, 17 01 02, 17 01 07, 17 01 81, 17 05 03, 17 05 04, 17 05 06, 19 05 01, 19 05 02, 19 05 03, 19 06 04, 19 08 01, 19 08 02, 19 08 05, 19 10 04, 19 12 09 19 12 12, 20 03 01, 20 03 03","methodology":"Pobieranie próbek do badań fizycznych, chemicznych i biologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań fizycznych, chemicznych i biologicznych","reference":"PB-14/RZ wydanie 1 z dnia 02.03.2020 r.","norm_bases":["PB-14/RZ wydanie 1 z dnia 02.03.2020 r."],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":"Pobieranie próbek wykonywane dla celów obszaru regulowanego objętego: Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2023 poz. 23), Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015 poz. 1277). O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Odpady O) : kod 01 04 09 10 01 01 , 10 01 02, 10 01 03, 10 02 02, 10 09 03, 10 12 03, 17 01 02, 17 01 07, 17 01 81, 17 05 03, 17 05 04, 17 05 06, 19 05 01, 19 05 02, 19 05 03, 19 06 04, 19 08 01, 19 08 02, 19 08 05, 19 10 04, 19 12 09 19 12 12, 20 03 01, 20 03 03 Pobieranie próbek do badań fizycznych, chemicznych i biologicznych PB-14/RZ wydanie 1 z dnia 02.03.2020 r. Odpady O) : kod 01 04 09 10 01 01 , 10 01 02, 10 01 03, 10 02 02, 10 09 03, 10 12 03, 17 01 02, 17 01 07, 17 01 81, 17 05 03, 17 05 04, 17 05 06, 19 05 01, 19 05 02, 19 05 03, 19 06 04, 19 08 01, 19 08 02, 19 08 05, 19 10 04, 19 12 09 19 12 12, 20 03 01, 20 03 03 Pobieranie probek do badan fizycznych, chemicznych i biologicznych PB-14/RZ wydanie 1 z dnia 02.03.2020 r.","categories":["environment"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for physical, chemical and biological testing","search_en":"Sampling for physical, chemical and biological testing PB-14/RZ wydanie 1 z dnia 02.03.2020 r."},{"_id":"6a836e34af14b9c0e7b1e841","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Osady ściekowe Odpady O) : kod 19 08 05","methodology":"Pobieranie próbek do badań fizycznych, chemicznych i biologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań fizycznych, chemicznych i biologicznych","reference":"PN-EN ISO 5667-13:2011","norm_bases":["PN-EN ISO 5667-13:2011"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":"Pobieranie próbek wykonywane dla celów obszaru regulowanego objętego: Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2023 poz. 23), Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015 poz. 1277). O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Osady ściekowe Odpady O) : kod 19 08 05 Pobieranie próbek do badań fizycznych, chemicznych i biologicznych PN-EN ISO 5667-13:2011 Osady sciekowe Odpady O) : kod 19 08 05 Pobieranie probek do badan fizycznych, chemicznych i biologicznych PN-EN ISO 5667-13:2011","categories":["water","environment"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for physical, chemical and biological testing","search_en":"Sampling for physical, chemical and biological testing PN-EN ISO 5667-13:2011"},{"_id":"6a836e34af14b9c0e7b1e842","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Odpady","methodology":"Badania interwencyjne (wg Programu DAB-11)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Badania interwencyjne (wg Programu DAB-11)","reference":"PB-11/CLB wydanie 1 z dnia 25.09.2023 r.","norm_bases":["PB-11/CLB wydanie 1 z dnia 25.09.2023 r."],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Odpady Badania interwencyjne (wg Programu DAB-11) PB-11/CLB wydanie 1 z dnia 25.09.2023 r. Odpady Badania interwencyjne (wg Programu DAB-11) PB-11/CLB wydanie 1 z dnia 25.09.2023 r.","categories":["environment"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Intervention testing (according to Programme DAB-11)","search_en":"Waste Intervention testing (according to Programme DAB-11) PB-11/CLB wydanie 1 z dnia 25.09.2023 r.","test_object_en":"Waste","search_zh":"废物 干预性检验（依据 DAB-11 计划） PB-11/CLB wydanie 1 z dnia 25.09.2023 r.","test_object_zh":"废物","methodology_zh":"干预性检验（依据 DAB-11 计划）"},{"_id":"6a836e34af14b9c0e7b1e843","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Odpady","methodology":"Oznaczanie składu morfologicznego do badań interwencyjnych (wg Programu DAB-11)","parameters":[],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Oznaczanie składu morfologicznego do badań interwencyjnych (wg Programu DAB-11)\nMetoda wagowa","reference":"PB-01/CLB wydanie 2 z dnia 30.05.2022 r.","norm_bases":["PB-01/CLB wydanie 2 z dnia 30.05.2022 r."],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Odpady Oznaczanie składu morfologicznego do badań interwencyjnych (wg Programu DAB-11)\nMetoda wagowa PB-01/CLB wydanie 2 z dnia 30.05.2022 r. Odpady Oznaczanie skladu morfologicznego do badan interwencyjnych (wg Programu DAB-11)\nMetoda wagowa PB-01/CLB wydanie 2 z dnia 30.05.2022 r.","categories":["environment"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Waste Gravimetric method PB-01/CLB wydanie 2 z dnia 30.05.2022 r.","technique_en":"Gravimetric method","test_object_en":"Waste","search_zh":"废物 重量法 PB-01/CLB wydanie 2 z dnia 30.05.2022 r.","technique_zh":"重量法","test_object_zh":"废物"},{"_id":"6a836e34af14b9c0e7b1e844","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych","methodology":"Natężenie pola elektrycznego:","parameters":[{"name":"- w zakresie częstotliwości 50 Hz"},{"name":"Zakres","range":"(0,9 - 51 400) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego:\nZakres:\n- w zakresie częstotliwości 50 Hz\nZakres (0,9 - 51 400) V/m\nMetoda pomiarowa bezpośrednia","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku wykonywane na potrzeby obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Natężenie pola elektrycznego:\nZakres:\n- w zakresie częstotliwości 50 Hz\nZakres (0,9 - 51 400) V/m\nMetoda pomiarowa bezpośrednia Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630) Srodowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Natezenie pola elektrycznego:\nZakres:\n- w zakresie czestotliwosci 50 Hz\nZakres (0,9 - 51 400) V/m\nMetoda pomiarowa bezposrednia Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","categories":["environment"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electric field strength:","parameters_en":[{"name":"- w zakresie częstotliwości 50 Hz"},{"name":"Range","range":"(0,9 - 51 400) V/m"}],"search_en":"Environment – electromagnetic field in the vicinity of electric power substations and power lines Electric field strength: Direct measurement method Range Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","technique_en":"Direct measurement method","test_object_en":"Environment – electromagnetic field in the vicinity of electric power substations and power lines","methodology_zh":"电场强度：","parameters_zh":[{"name":"- w zakresie częstotliwości 50 Hz"},{"name":"范围","range":"(0,9 - 51 400) V/m"}],"search_zh":"环境 — 变电站与输电线路周围的电磁场 电场强度： 直接测量法 范围 Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","technique_zh":"直接测量法","test_object_zh":"环境 — 变电站与输电线路周围的电磁场"},{"_id":"6a836e34af14b9c0e7b1e845","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych","methodology":"Indukcja magnetyczna:","parameters":[{"name":"- w zakresie częstotliwości 50 Hz"},{"name":"Zakres","range":"0,11 µT - 9,66 mT"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Indukcja magnetyczna:\nZakres:\n- w zakresie częstotliwości 50 Hz\nZakres 0,11 µT - 9,66 mT\nMetoda pomiarowa bezpośrednia","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku wykonywane na potrzeby obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Indukcja magnetyczna:\nZakres:\n- w zakresie częstotliwości 50 Hz\nZakres 0,11 µT - 9,66 mT\nMetoda pomiarowa bezpośrednia Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630) Srodowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Indukcja magnetyczna:\nZakres:\n- w zakresie czestotliwosci 50 Hz\nZakres 0,11 µT - 9,66 mT\nMetoda pomiarowa bezposrednia Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","categories":["environment"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic flux density:","parameters_en":[{"name":"- w zakresie częstotliwości 50 Hz"},{"name":"Range","range":"0,11 µT - 9,66 mT"}],"search_en":"Environment – electromagnetic field in the vicinity of electric power substations and power lines Magnetic flux density: Direct measurement method Range Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","technique_en":"Direct measurement method","test_object_en":"Environment – electromagnetic field in the vicinity of electric power substations and power lines","parameters_zh":[{"name":"- w zakresie częstotliwości 50 Hz"},{"name":"范围","range":"0,11 µT - 9,66 mT"}],"search_zh":"环境 — 变电站与输电线路周围的电磁场 磁感应强度： 直接测量法 范围 Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","technique_zh":"直接测量法","test_object_zh":"环境 — 变电站与输电线路周围的电磁场","methodology_zh":"磁感应强度："},{"_id":"6a836e34af14b9c0e7b1e846","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych","methodology":"Natężenie pola magnetycznego (z obliczeń)","parameters":[{"name":"- w zakresie częstotliwości 50 Hz"}],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego (z obliczeń)\n- w zakresie częstotliwości 50 Hz","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku wykonywane na potrzeby obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Natężenie pola magnetycznego (z obliczeń)\n- w zakresie częstotliwości 50 Hz Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630) Srodowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Natezenie pola magnetycznego (z obliczen)\n- w zakresie czestotliwosci 50 Hz Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","categories":["environment"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength (calculated)","search_en":"Environment – electromagnetic field in the vicinity of electric power substations and power lines Magnetic field strength (calculated) Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","test_object_en":"Environment – electromagnetic field in the vicinity of electric power substations and power lines","search_zh":"环境 — 变电站与输电线路周围的电磁场 Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","test_object_zh":"环境 — 变电站与输电线路周围的电磁场"},{"_id":"6a836e34af14b9c0e7b1e847","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe)","methodology":"Natężenie pola elektrycznego:","parameters":[{"name":"- w zakresie częstotliwości od 80 MHz do 60 GHz"},{"name":"Zakres","range":"(0,45 – 208) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego:\nZakres:\n- w zakresie częstotliwości od 80 MHz do 60 GHz\nZakres (0,45 – 208) V/m\nMetoda pomiarowa bezpośrednia","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku wykonywane na potrzeby obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe) Natężenie pola elektrycznego:\nZakres:\n- w zakresie częstotliwości od 80 MHz do 60 GHz\nZakres (0,45 – 208) V/m\nMetoda pomiarowa bezpośrednia Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630) Srodowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe) Natezenie pola elektrycznego:\nZakres:\n- w zakresie czestotliwosci od 80 MHz do 60 GHz\nZakres (0,45 – 208) V/m\nMetoda pomiarowa bezposrednia Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","categories":["environment"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electric field strength:","parameters_en":[{"name":"- w zakresie częstotliwości od 80 MHz do 60 GHz"},{"name":"Range","range":"(0,45 – 208) V/m"}],"search_en":"Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Electric field strength: Direct measurement method Range Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","technique_en":"Direct measurement method","test_object_en":"Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements)","methodology_zh":"电场强度：","parameters_zh":[{"name":"- w zakresie częstotliwości od 80 MHz do 60 GHz"},{"name":"范围","range":"(0,45 – 208) V/m"}],"search_zh":"环境 – 无线电通信设施周围的电磁场（宽带测量） 电场强度： 直接测量法 范围 Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","technique_zh":"直接测量法","test_object_zh":"环境 – 无线电通信设施周围的电磁场（宽带测量）"},{"_id":"6a836e34af14b9c0e7b1e848","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe)","methodology":"Natężenie pola magnetycznego: (z obliczeń)","parameters":[{"name":"- w zakresie częstotliwości od 80 MHz do 60 GHz"}],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego: (z obliczeń)\n- w zakresie częstotliwości od 80 MHz do 60 GHz","reference":"Punkt 3 załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz.2630)","norm_bases":["Punkt 3 załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz.2630)"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku wykonywane na potrzeby obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe) Natężenie pola magnetycznego: (z obliczeń)\n- w zakresie częstotliwości od 80 MHz do 60 GHz Punkt 3 załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz.2630) Srodowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe) Natezenie pola magnetycznego: (z obliczen)\n- w zakresie czestotliwosci od 80 MHz do 60 GHz Punkt 3 zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz.2630)","categories":["environment"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Punkt 3 załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz.2630)","test_object_en":"Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements)","search_zh":"环境 – 无线电通信设施周围的电磁场（宽带测量） Punkt 3 załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz.2630)","test_object_zh":"环境 – 无线电通信设施周围的电磁场（宽带测量）"},{"_id":"6a836e34af14b9c0e7b1e849","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe)","methodology":"Gęstość mocy: (z obliczeń)","parameters":[{"name":"- w zakresie częstotliwości od 300 MHz do 60 GHz"}],"technique":null,"techniques":[],"computed":[],"activity":"Gęstość mocy: (z obliczeń)\n- w zakresie częstotliwości od 300 MHz do 60 GHz","reference":"Punkt 3 załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz.2630)","norm_bases":["Punkt 3 załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz.2630)"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku wykonywane na potrzeby obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe) Gęstość mocy: (z obliczeń)\n- w zakresie częstotliwości od 300 MHz do 60 GHz Punkt 3 załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz.2630) Srodowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe) Gestosc mocy: (z obliczen)\n- w zakresie czestotliwosci od 300 MHz do 60 GHz Punkt 3 zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz.2630)","categories":["environment"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Punkt 3 załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz.2630)","test_object_en":"Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements)","search_zh":"环境 – 无线电通信设施周围的电磁场（宽带测量） Punkt 3 załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz.2630)","test_object_zh":"环境 – 无线电通信设施周围的电磁场（宽带测量）"},{"_id":"6a836e34af14b9c0e7b1e84a","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)","parameters":[{"name":"Zakres","range":"(10,0 – 2000) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (10,0 – 2000) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":"Pracownia w Rzeszowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (10,0 – 2000) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999 Woda Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna)\nZakres (10,0 – 2000) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total content of calcium and magnesium (total hardness)","parameters_en":[{"name":"Range","range":"(10,0 – 2000) mg/l CaCO3"}],"search_en":"Water Total content of calcium and magnesium (total hardness) Titrimetric method Range PN-ISO 6059:1999","technique_en":"Titrimetric method","test_object_en":"Water","methodology_zh":"钙与镁总量（总硬度）","parameters_zh":[{"name":"范围","range":"(10,0 – 2000) mg/l CaCO3"}],"search_zh":"水 钙与镁总量（总硬度） 滴定法 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"水"},{"_id":"6a836e34af14b9c0e7b1e84b","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie rtęci","parameters":[{"name":"Zakres","range":"(0,020 – 0,50) µg/l"}],"technique":"Metoda atomowej spektrometrii fluorescencyjnej (AFS)","techniques":["Metoda atomowej spektrometrii fluorescencyjnej (AFS)"],"computed":[],"activity":"Stężenie rtęci\nZakres (0,020 – 0,50) µg/l\nMetoda atomowej spektrometrii fluorescencyjnej (AFS)","reference":"PN-EN ISO 17852:2009","norm_bases":["PN-EN ISO 17852:2009"],"lab_section":"Pracownia w Rzeszowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie rtęci\nZakres (0,020 – 0,50) µg/l\nMetoda atomowej spektrometrii fluorescencyjnej (AFS) PN-EN ISO 17852:2009 Woda Stezenie rteci\nZakres (0,020 – 0,50) µg/l\nMetoda atomowej spektrometrii fluorescencyjnej (AFS) PN-EN ISO 17852:2009","categories":["water"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury concentration","parameters_en":[{"name":"Range","range":"(0,020 – 0,50) µg/l"}],"search_en":"Water Mercury concentration Atomic fluorescence spectrometry (AFS) Range PN-EN ISO 17852:2009","technique_en":"Atomic fluorescence spectrometry (AFS)","test_object_en":"Water","methodology_zh":"汞浓度","parameters_zh":[{"name":"范围","range":"(0,020 – 0,50) µg/l"}],"search_zh":"水 汞浓度 原子荧光光谱法（AFS） 范围 PN-EN ISO 17852:2009","test_object_zh":"水","technique_zh":"原子荧光光谱法（AFS）"},{"_id":"6a836e34af14b9c0e7b1e84c","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie anionów","parameters":[{"name":"Fluorki","range":"(0,10 – 100) mg/l"},{"name":"Chlorki","range":"(0,50 – 5 000) mg/l"},{"name":"Azotany","range":"(0,10 – 500) mg/l"},{"name":"Siarczany","range":"(0,50 – 10 000) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcja konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcja konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie anionów\nZakres:\nFluorki (0,10 – 100) mg/l\nChlorki (0,50 – 5 000) mg/l\nAzotany (0,10 – 500) mg/l\nSiarczany (0,50 – 10 000) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczną (IC-CD)","reference":"PN-EN ISO10304-1:2009+AC:2012","norm_bases":["PN-EN ISO10304-1:2009+AC:2012"],"lab_section":"Pracownia w Rzeszowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie anionów\nZakres:\nFluorki (0,10 – 100) mg/l\nChlorki (0,50 – 5 000) mg/l\nAzotany (0,10 – 500) mg/l\nSiarczany (0,50 – 10 000) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczną (IC-CD) PN-EN ISO10304-1:2009+AC:2012 Woda, scieki Stezenie anionow\nZakres:\nFluorki (0,10 – 100) mg/l\nChlorki (0,50 – 5 000) mg/l\nAzotany (0,10 – 500) mg/l\nSiarczany (0,50 – 10 000) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO10304-1:2009+AC:2012","categories":["water"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Anion concentrations","parameters_en":[{"name":"Fluorides","range":"(0,10 – 100) mg/l"},{"name":"Chlorides","range":"(0,50 – 5 000) mg/l"},{"name":"Nitrates","range":"(0,10 – 500) mg/l"},{"name":"Sulfates","range":"(0,50 – 10 000) mg/l"}],"search_en":"Water, wastewater Anion concentrations Ion chromatography with conductometric detection (IC-CD) Fluorides Chlorides Nitrates Sulfates PN-EN ISO10304-1:2009+AC:2012","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water, wastewater","methodology_zh":"阴离子浓度","parameters_zh":[{"name":"氟化物","range":"(0,10 – 100) mg/l"},{"name":"氯化物","range":"(0,50 – 5 000) mg/l"},{"name":"硝酸盐","range":"(0,10 – 500) mg/l"},{"name":"硫酸盐","range":"(0,50 – 10 000) mg/l"}],"search_zh":"水、废水 阴离子浓度 氟化物 氯化物 硝酸盐 硫酸盐 PN-EN ISO10304-1:2009+AC:2012","test_object_zh":"水、废水"},{"_id":"6a836e34af14b9c0e7b1e84d","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5, BZT2+5","parameters":[{"name":"Zakres","range":"(0,5 – 6,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5, BZT2+5\nZakres (0,5 – 6,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":"Pracownia w Rzeszowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu - BZT5, BZT2+5\nZakres (0,5 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Woda, scieki Biochemiczne zapotrzebowanie tlenu - BZT5, BZT2+5\nZakres (0,5 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand - BOD5, BOD2+5","parameters_en":[{"name":"Range","range":"(0,5 – 6,0) mg/l O2"}],"search_en":"Water, wastewater Biochemical oxygen demand - BOD5, BOD2+5 Electrochemical method Range PN-EN 1899-2:2002","technique_en":"Electrochemical method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,5 – 6,0) mg/l O2"}],"search_zh":"水、废水 生化需氧量 － BOD5、BOD2+5 电化学法 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"水、废水","methodology_zh":"生化需氧量 － BOD5、BOD2+5"},{"_id":"6a836e34af14b9c0e7b1e84e","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5, BZT 2+5","parameters":[{"name":"Zakres","range":"(3 – 6000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5, BZT 2+5\nZakres (3 – 6000) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Pracownia w Rzeszowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu - BZT5, BZT 2+5\nZakres (3 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Woda, scieki Biochemiczne zapotrzebowanie tlenu - BZT5, BZT 2+5\nZakres (3 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(3 – 6000) mg/l O2"}],"search_en":"Water, wastewater Electrochemical method Range PN-EN ISO 5815-1:2019-12","technique_en":"Electrochemical method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(3 – 6000) mg/l O2"}],"search_zh":"水、废水 电化学法 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"水、废水"},{"_id":"6a836e34af14b9c0e7b1e84f","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0 – 2000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 2000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Pracownia w Rzeszowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Zawiesiny ogólne\nZakres (2,0 – 2000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, scieki Zawiesiny ogolne\nZakres (2,0 – 2000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2,0 – 2000) mg/l"}],"search_en":"Water, wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 2000) mg/l"}],"search_zh":"水、废水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"水、废水"},{"_id":"6a836e34af14b9c0e7b1e850","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,050 – 20,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,050 – 20,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Pracownia w Rzeszowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu amonowego\nZakres (0,050 – 20,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, scieki Stezenie azotu amonowego\nZakres (0,050 – 20,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,050 – 20,0) mg/l"}],"search_en":"Water, wastewater Ammonium nitrogen concentration Spectrophotometric method Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,050 – 20,0) mg/l"}],"search_zh":"水、废水 氨氮浓度 分光光度法 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a836e34af14b9c0e7b1e851","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(3,00 − 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (3,00 − 1000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":"Pracownia w Rzeszowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu amonowego\nZakres (3,00 − 1000) mg/l\nMetoda miareczkowa PN-ISO 5664:2002 Woda, scieki Stezenie azotu amonowego\nZakres (3,00 − 1000) mg/l\nMetoda miareczkowa PN-ISO 5664:2002","categories":["water"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(3,00 − 1000) mg/l"}],"search_en":"Water, wastewater Ammonium nitrogen concentration Titrimetric method Range PN-ISO 5664:2002","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(3,00 − 1000) mg/l"}],"search_zh":"水、废水 氨氮浓度 滴定法 范围 PN-ISO 5664:2002","technique_zh":"滴定法","test_object_zh":"水、废水"},{"_id":"6a836e34af14b9c0e7b1e852","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,0020 – 10,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres (0,0020 – 10,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Pracownia w Rzeszowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu azotynowego\nZakres (0,0020 – 10,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, scieki Stezenie azotu azotynowego\nZakres (0,0020 – 10,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,0020 – 10,0) mg/l"}],"search_en":"Water, wastewater Nitrite nitrogen concentration Spectrophotometric method Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,0020 – 10,0) mg/l"}],"search_zh":"水、废水 亚硝态氮浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a836e34af14b9c0e7b1e853","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu ogólnego Suma NKjeld, NNO2 i NNO3 (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu ogólnego Suma NKjeld, NNO2 i NNO3 (z obliczeń)","reference":"PB-26/CLB Wydanie 1 z dnia 16.01.2026","norm_bases":["PB-26/CLB Wydanie 1 z dnia 16.01.2026"],"lab_section":"Pracownia w Rzeszowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu ogólnego Suma NKjeld, NNO2 i NNO3 (z obliczeń) PB-26/CLB Wydanie 1 z dnia 16.01.2026 Woda, scieki Stezenie azotu ogolnego Suma NKjeld, NNO2 i NNO3 (z obliczen) PB-26/CLB Wydanie 1 z dnia 16.01.2026","categories":["water"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Water, wastewater PB-26/CLB Wydanie 1 z dnia 16.01.2026","test_object_en":"Water, wastewater","search_zh":"水、废水 PB-26/CLB Wydanie 1 z dnia 16.01.2026","test_object_zh":"水、废水"},{"_id":"6a836e34af14b9c0e7b1e854","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie fosforanów rozpuszczonych","parameters":[{"name":"Zakres","range":"(0,030 – 307) mg/l"},{"name":"Zakres","range":"(0,010 – 100) mg/l P"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforanów rozpuszczonych\nZakres:\nZakres (0,030 – 307) mg/l\nZakres (0,010 – 100) mg/l P\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 pkt 4+ Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 pkt 4+ Ap1:2010+Ap2:2010"],"lab_section":"Pracownia w Rzeszowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie fosforanów rozpuszczonych\nZakres:\nZakres (0,030 – 307) mg/l\nZakres (0,010 – 100) mg/l P\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt 4+ Ap1:2010+Ap2:2010 Woda, scieki Stezenie fosforanow rozpuszczonych\nZakres:\nZakres (0,030 – 307) mg/l\nZakres (0,010 – 100) mg/l P\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt 4+ Ap1:2010+Ap2:2010","categories":["water"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissolved phosphate concentration","parameters_en":[{"name":"Range","range":"(0,030 – 307) mg/l"},{"name":"Range","range":"(0,010 – 100) mg/l P"}],"search_en":"Water, wastewater Dissolved phosphate concentration Spectrophotometric method Range Range PN-EN ISO 6878:2006 pkt 4+ Ap1:2010+Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,030 – 307) mg/l"},{"name":"范围","range":"(0,010 – 100) mg/l P"}],"search_zh":"水、废水 溶解性磷酸盐浓度 分光光度法 范围 范围 PN-EN ISO 6878:2006 pkt 4+ Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"溶解性磷酸盐浓度"},{"_id":"6a836e34af14b9c0e7b1e855","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,025 – 100) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,025 – 100) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 pkt 7+ Ap1:2010 +Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 pkt 7+ Ap1:2010 +Ap2:2010"],"lab_section":"Pracownia w Rzeszowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie fosforu ogólnego\nZakres (0,025 – 100) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt 7+ Ap1:2010 +Ap2:2010 Woda, scieki Stezenie fosforu ogolnego\nZakres (0,025 – 100) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt 7+ Ap1:2010 +Ap2:2010","categories":["water"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,025 – 100) mg/l"}],"search_en":"Water, wastewater Total phosphorus concentration Spectrophotometric method Range PN-EN ISO 6878:2006 pkt 7+ Ap1:2010 +Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,025 – 100) mg/l"}],"search_zh":"水、废水 总磷浓度 分光光度法 范围 PN-EN ISO 6878:2006 pkt 7+ Ap1:2010 +Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a836e34af14b9c0e7b1e856","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Zasadowość ogólna","parameters":[{"name":"Zakres","range":"(10,0 – 2000) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zasadowość ogólna\nZakres (10,0 – 2000) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-EN ISO 9963-1:2001 pkt 8.2+ Ap1:2004","norm_bases":["PN-EN ISO 9963-1:2001 pkt 8.2+ Ap1:2004"],"lab_section":"Pracownia w Rzeszowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Zasadowość ogólna\nZakres (10,0 – 2000) mg/l CaCO3\nMetoda miareczkowa PN-EN ISO 9963-1:2001 pkt 8.2+ Ap1:2004 Woda, scieki Zasadowosc ogolna\nZakres (10,0 – 2000) mg/l CaCO3\nMetoda miareczkowa PN-EN ISO 9963-1:2001 pkt 8.2+ Ap1:2004","categories":["water"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total alkalinity","parameters_en":[{"name":"Range","range":"(10,0 – 2000) mg/l CaCO3"}],"search_en":"Water, wastewater Total alkalinity Titrimetric method Range PN-EN ISO 9963-1:2001 pkt 8.2+ Ap1:2004","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(10,0 – 2000) mg/l CaCO3"}],"search_zh":"水、废水 总碱度 滴定法 范围 PN-EN ISO 9963-1:2001 pkt 8.2+ Ap1:2004","technique_zh":"滴定法","test_object_zh":"水、废水","methodology_zh":"总碱度"},{"_id":"6a836e34af14b9c0e7b1e857","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Chemiczne zapotrzebowanie tlenu – ChZT-Cr","parameters":[{"name":"Zakres","range":"(6,0 – 5 000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu – ChZT-Cr\nZakres (6,0 – 5 000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705: 2005","norm_bases":["PN-ISO 15705: 2005"],"lab_section":"Pracownia w Rzeszowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Chemiczne zapotrzebowanie tlenu – ChZT-Cr\nZakres (6,0 – 5 000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705: 2005 Woda, scieki Chemiczne zapotrzebowanie tlenu – ChZT-Cr\nZakres (6,0 – 5 000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705: 2005","categories":["water"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand – COD-Cr","parameters_en":[{"name":"Range","range":"(6,0 – 5 000) mg/l O2"}],"search_en":"Water, wastewater Chemical oxygen demand – COD-Cr Spectrophotometric method Range PN-ISO 15705: 2005","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(6,0 – 5 000) mg/l O2"}],"search_zh":"水、废水 化学需氧量（COD-Cr） 分光光度法 范围 PN-ISO 15705: 2005","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"化学需氧量（COD-Cr）"},{"_id":"6a836e34af14b9c0e7b1e858","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Indeks oleju mineralnego","parameters":[{"name":"woda","range":"(0,050 – 4,0) mg/l"},{"name":"ścieki","range":"(1,0 − 30) mg/l"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Indeks oleju mineralnego\nZakres:\nwoda (0,050 – 4,0) mg/l\nścieki (1,0 − 30) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN ISO 9377-2:2003","norm_bases":["PN-EN ISO 9377-2:2003"],"lab_section":"Pracownia w Rzeszowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Indeks oleju mineralnego\nZakres:\nwoda (0,050 – 4,0) mg/l\nścieki (1,0 − 30) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN ISO 9377-2:2003 Woda, scieki Indeks oleju mineralnego\nZakres:\nwoda (0,050 – 4,0) mg/l\nscieki (1,0 − 30) mg/l\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN ISO 9377-2:2003","categories":["water","petro"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mineral oil index","parameters_en":[{"name":"water","range":"(0,050 – 4,0) mg/l"},{"name":"wastewater","range":"(1,0 − 30) mg/l"}],"search_en":"Water, wastewater Mineral oil index Gas chromatography with flame ionization detection (GC-FID) water wastewater PN-EN ISO 9377-2:2003","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Water, wastewater","search_zh":"水、废水 矿物油指数 气相色谱-氢火焰离子化检测法（GC-FID） 水 PN-EN ISO 9377-2:2003","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"水、废水","methodology_zh":"矿物油指数","parameters_zh":[{"name":"水","range":"(0,050 – 4,0) mg/l"},{"name":"ścieki","range":"(1,0 − 30) mg/l"}]},{"_id":"6a836e34af14b9c0e7b1e859","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie węglowodorów aromatycznych","parameters":[{"name":"benzen","range":"(0,10 − 100) µg/l"},{"name":"toluen","range":"(0,10 – 100) µg/l"},{"name":"m-ksylen","range":"(0,10 − 100) µg/l"},{"name":"p-ksylen","range":"(0,10 − 100) µg/l"},{"name":"o-ksylen","range":"(0,10 − 100) µg/l"},{"name":"etylobenzen","range":"(0,10 − 100) µg/l"}],"technique":"Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej z detekcją spektrometrią mas (HS-GC-MS)","techniques":["Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej z detekcją spektrometrią mas (HS-GC-MS)"],"computed":[],"activity":"Stężenie węglowodorów aromatycznych\nZakres:\nbenzen (0,10 − 100) µg/l\ntoluen (0,10 – 100) µg/l\nm-ksylen (0,10 − 100) µg/l\np-ksylen (0,10 − 100) µg/l\no-ksylen (0,10 − 100) µg/l\netylobenzen (0,10 − 100) µg/l\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej z detekcją spektrometrią mas (HS-GC-MS)","reference":"PN-ISO 11423-1:2002 część 1","norm_bases":["PN-ISO 11423-1:2002 część 1"],"lab_section":"Pracownia w Rzeszowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie węglowodorów aromatycznych\nZakres:\nbenzen (0,10 − 100) µg/l\ntoluen (0,10 – 100) µg/l\nm-ksylen (0,10 − 100) µg/l\np-ksylen (0,10 − 100) µg/l\no-ksylen (0,10 − 100) µg/l\netylobenzen (0,10 − 100) µg/l\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej z detekcją spektrometrią mas (HS-GC-MS) PN-ISO 11423-1:2002 część 1 Woda, scieki Stezenie weglowodorow aromatycznych\nZakres:\nbenzen (0,10 − 100) µg/l\ntoluen (0,10 – 100) µg/l\nm-ksylen (0,10 − 100) µg/l\np-ksylen (0,10 − 100) µg/l\no-ksylen (0,10 − 100) µg/l\netylobenzen (0,10 − 100) µg/l\nMetoda chromatografii gazowej z analiza fazy nadpowierzchniowej z detekcja spektrometria mas (HS-GC-MS) PN-ISO 11423-1:2002 czesc 1","categories":["water"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of aromatic hydrocarbons","parameters_en":[{"name":"benzene","range":"(0,10 − 100) µg/l"},{"name":"toluene","range":"(0,10 – 100) µg/l"},{"name":"m-xylene","range":"(0,10 − 100) µg/l"},{"name":"p-xylene","range":"(0,10 − 100) µg/l"},{"name":"o-xylene","range":"(0,10 − 100) µg/l"},{"name":"ethylbenzene","range":"(0,10 − 100) µg/l"}],"search_en":"Water, wastewater Concentration of aromatic hydrocarbons Headspace gas chromatography with mass spectrometry detection (HS-GC-MS) benzene toluene m-xylene p-xylene o-xylene ethylbenzene PN-ISO 11423-1:2002 część 1","technique_en":"Headspace gas chromatography with mass spectrometry detection (HS-GC-MS)","test_object_en":"Water, wastewater","search_zh":"水、废水 芳香烃浓度 顶空气相色谱-质谱法（HS-GC-MS） 苯 甲苯 间二甲苯 邻二甲苯 乙苯 PN-ISO 11423-1:2002 część 1","test_object_zh":"水、废水","parameters_zh":[{"name":"苯","range":"(0,10 − 100) µg/l"},{"name":"甲苯","range":"(0,10 – 100) µg/l"},{"name":"间二甲苯","range":"(0,10 − 100) µg/l"},{"name":"p-ksylen","range":"(0,10 − 100) µg/l"},{"name":"邻二甲苯","range":"(0,10 − 100) µg/l"},{"name":"乙苯","range":"(0,10 − 100) µg/l"}],"methodology_zh":"芳香烃浓度","technique_zh":"顶空气相色谱-质谱法（HS-GC-MS）"},{"_id":"6a836e34af14b9c0e7b1e85a","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie lotnych związków chloroorganicznych","parameters":[{"name":"Dichlorometan","range":"(2,0 – 100) µg/l"},{"name":"trichlorometan (chloroform, CHCl3)","range":"(0,10 – 100) µg/l"},{"name":"1,2-dichloroetan (EDC)","range":"(1,0 – 100) µg/l"},{"name":"tetrachlorometan (tetrachlorek węgla, CCl4)","range":"(0,10 – 100) µg/l"},{"name":"trichloroetylen (TRI)","range":"(0,10 – 100) µg/l"},{"name":"tetrachloroetylen (PER)","range":"(0,10 – 100) µg/l"},{"name":"1,2,4-trichlorobenzen","range":"(0,040 – 3,5) µg/l"},{"name":"1,2,3-trichlorobenzen","range":"(0,040 – 3,5) µg/l"},{"name":"1,3,5-trichlorobenzen","range":"(0,040 − 3,5) µg/l"},{"name":"Heksachlorobutadien","range":"(0,050 − 10) µg/l"}],"technique":"Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej z detekcją spektrometrią mas (HS-GC-MS)","techniques":["Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej z detekcją spektrometrią mas (HS-GC-MS)"],"computed":[],"activity":"Stężenie lotnych związków chloroorganicznych\nZakres:\nDichlorometan (2,0 – 100) µg/l\ntrichlorometan (chloroform, CHCl3) (0,10 – 100) µg/l\n1,2-dichloroetan (EDC) (1,0 – 100) µg/l\ntetrachlorometan (tetrachlorek węgla, CCl4) (0,10 – 100) µg/l\ntrichloroetylen (TRI) (0,10 – 100) µg/l\ntetrachloroetylen (PER) (0,10 – 100) µg/l\n1,2,4-trichlorobenzen (0,040 – 3,5) µg/l\n1,2,3-trichlorobenzen (0,040 – 3,5) µg/l\n1,3,5-trichlorobenzen (0,040 − 3,5) µg/l\nHeksachlorobutadien (0,050 − 10) µg/l\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej z detekcją spektrometrią mas (HS-GC-MS)","reference":"PN-EN ISO 10301:2002 rozdział 3","norm_bases":["PN-EN ISO 10301:2002 rozdział 3"],"lab_section":"Pracownia w Rzeszowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie lotnych związków chloroorganicznych\nZakres:\nDichlorometan (2,0 – 100) µg/l\ntrichlorometan (chloroform, CHCl3) (0,10 – 100) µg/l\n1,2-dichloroetan (EDC) (1,0 – 100) µg/l\ntetrachlorometan (tetrachlorek węgla, CCl4) (0,10 – 100) µg/l\ntrichloroetylen (TRI) (0,10 – 100) µg/l\ntetrachloroetylen (PER) (0,10 – 100) µg/l\n1,2,4-trichlorobenzen (0,040 – 3,5) µg/l\n1,2,3-trichlorobenzen (0,040 – 3,5) µg/l\n1,3,5-trichlorobenzen (0,040 − 3,5) µg/l\nHeksachlorobutadien (0,050 − 10) µg/l\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej z detekcją spektrometrią mas (HS-GC-MS) PN-EN ISO 10301:2002 rozdział 3 Woda, scieki Stezenie lotnych zwiazkow chloroorganicznych\nZakres:\nDichlorometan (2,0 – 100) µg/l\ntrichlorometan (chloroform, CHCl3) (0,10 – 100) µg/l\n1,2-dichloroetan (EDC) (1,0 – 100) µg/l\ntetrachlorometan (tetrachlorek wegla, CCl4) (0,10 – 100) µg/l\ntrichloroetylen (TRI) (0,10 – 100) µg/l\ntetrachloroetylen (PER) (0,10 – 100) µg/l\n1,2,4-trichlorobenzen (0,040 – 3,5) µg/l\n1,2,3-trichlorobenzen (0,040 – 3,5) µg/l\n1,3,5-trichlorobenzen (0,040 − 3,5) µg/l\nHeksachlorobutadien (0,050 − 10) µg/l\nMetoda chromatografii gazowej z analiza fazy nadpowierzchniowej z detekcja spektrometria mas (HS-GC-MS) PN-EN ISO 10301:2002 rozdzial 3","categories":["water"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of volatile organochlorine compounds","parameters_en":[{"name":"Dichloromethane","range":"(2,0 – 100) µg/l"},{"name":"trichlorometan (chloroform, CHCl3)","range":"(0,10 – 100) µg/l"},{"name":"1,2-dichloroethane (EDC)","range":"(1,0 – 100) µg/l"},{"name":"tetrachloromethane (carbon tetrachloride, CCl4)","range":"(0,10 – 100) µg/l"},{"name":"trichloroethylene (TRI)","range":"(0,10 – 100) µg/l"},{"name":"tetrachloroethylene (PER)","range":"(0,10 – 100) µg/l"},{"name":"1,2,4-trichlorobenzene","range":"(0,040 – 3,5) µg/l"},{"name":"1,2,3-trichlorobenzene","range":"(0,040 – 3,5) µg/l"},{"name":"1,3,5-trichlorobenzene","range":"(0,040 − 3,5) µg/l"},{"name":"Hexachlorobutadiene","range":"(0,050 − 10) µg/l"}],"search_en":"Water, wastewater Concentration of volatile organochlorine compounds Headspace gas chromatography with mass spectrometry detection (HS-GC-MS) Dichloromethane 1,2-dichloroethane (EDC) tetrachloromethane (carbon tetrachloride, CCl4) trichloroethylene (TRI) tetrachloroethylene (PER) 1,2,4-trichlorobenzene 1,2,3-trichlorobenzene 1,3,5-trichlorobenzene Hexachlorobutadiene PN-EN ISO 10301:2002 rozdział 3","technique_en":"Headspace gas chromatography with mass spectrometry detection (HS-GC-MS)","test_object_en":"Water, wastewater","search_zh":"水、废水 顶空气相色谱-质谱法（HS-GC-MS） 二氯甲烷 1,2,4-三氯苯 1,2,3-三氯苯 1,3,5-三氯苯 六氯丁二烯 PN-EN ISO 10301:2002 rozdział 3","test_object_zh":"水、废水","parameters_zh":[{"name":"二氯甲烷","range":"(2,0 – 100) µg/l"},{"name":"trichlorometan (chloroform, CHCl3)","range":"(0,10 – 100) µg/l"},{"name":"1,2-dichloroetan (EDC)","range":"(1,0 – 100) µg/l"},{"name":"tetrachlorometan (tetrachlorek węgla, CCl4)","range":"(0,10 – 100) µg/l"},{"name":"trichloroetylen (TRI)","range":"(0,10 – 100) µg/l"},{"name":"tetrachloroetylen (PER)","range":"(0,10 – 100) µg/l"},{"name":"1,2,4-三氯苯","range":"(0,040 – 3,5) µg/l"},{"name":"1,2,3-三氯苯","range":"(0,040 – 3,5) µg/l"},{"name":"1,3,5-三氯苯","range":"(0,040 − 3,5) µg/l"},{"name":"六氯丁二烯","range":"(0,050 − 10) µg/l"}],"technique_zh":"顶空气相色谱-质谱法（HS-GC-MS）"},{"_id":"6a836e34af14b9c0e7b1e85b","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Suma trichlorobenzenów (TCB) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma trichlorobenzenów (TCB) (z obliczeń)","reference":"PN-EN ISO 10301:2002 rozdział 3","norm_bases":["PN-EN ISO 10301:2002 rozdział 3"],"lab_section":"Pracownia w Rzeszowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Suma trichlorobenzenów (TCB) (z obliczeń) PN-EN ISO 10301:2002 rozdział 3 Woda, scieki Suma trichlorobenzenow (TCB) (z obliczen) PN-EN ISO 10301:2002 rozdzial 3","categories":["water"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of trichlorobenzenes (TCB) (calculated)","search_en":"Water, wastewater Sum of trichlorobenzenes (TCB) (calculated) PN-EN ISO 10301:2002 rozdział 3","test_object_en":"Water, wastewater","search_zh":"水、废水 PN-EN ISO 10301:2002 rozdział 3","test_object_zh":"水、废水"},{"_id":"6a836e34af14b9c0e7b1e85c","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie ogólnego węgla organicznego (OWO)","parameters":[{"name":"Zakres","range":"(1,00 – 5 000) mg/l"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją w zakresie podczerwieni IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją w zakresie podczerwieni IR"],"computed":[],"activity":"Stężenie ogólnego węgla organicznego (OWO)\nZakres (1,00 – 5 000) mg/l\nMetoda wysokotemperaturowego spalania z detekcją w zakresie podczerwieni IR","reference":"PN-EN 1484:1999","norm_bases":["PN-EN 1484:1999"],"lab_section":"Pracownia w Rzeszowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie ogólnego węgla organicznego (OWO)\nZakres (1,00 – 5 000) mg/l\nMetoda wysokotemperaturowego spalania z detekcją w zakresie podczerwieni IR PN-EN 1484:1999 Woda, scieki Stezenie ogolnego wegla organicznego (OWO)\nZakres (1,00 – 5 000) mg/l\nMetoda wysokotemperaturowego spalania z detekcja w zakresie podczerwieni IR PN-EN 1484:1999","categories":["water"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total organic carbon concentration (TOC)","parameters_en":[{"name":"Range","range":"(1,00 – 5 000) mg/l"}],"search_en":"Water, wastewater Total organic carbon concentration (TOC) High-temperature combustion with infrared IR detection Range PN-EN 1484:1999","technique_en":"High-temperature combustion with infrared IR detection","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(1,00 – 5 000) mg/l"}],"search_zh":"水、废水 总有机碳浓度（TOC） 高温燃烧-红外（IR）检测法 范围 PN-EN 1484:1999","test_object_zh":"水、废水","methodology_zh":"总有机碳浓度（TOC）","technique_zh":"高温燃烧-红外（IR）检测法"},{"_id":"6a836e34af14b9c0e7b1e85d","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Całkowite substancje rozpuszczone (TDS)","parameters":[{"name":"Zakres","range":"(50,0 – 2000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Całkowite substancje rozpuszczone (TDS)\nZakres (50,0 – 2000) mg/l\nMetoda wagowa","reference":"PN-EN 15216:2022-03","norm_bases":["PN-EN 15216:2022-03"],"lab_section":"Pracownia w Rzeszowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Całkowite substancje rozpuszczone (TDS)\nZakres (50,0 – 2000) mg/l\nMetoda wagowa PN-EN 15216:2022-03 Woda, scieki Calkowite substancje rozpuszczone (TDS)\nZakres (50,0 – 2000) mg/l\nMetoda wagowa PN-EN 15216:2022-03","categories":["water"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total dissolved solids (TDS)","parameters_en":[{"name":"Range","range":"(50,0 – 2000) mg/l"}],"search_en":"Water, wastewater Total dissolved solids (TDS) Gravimetric method Range PN-EN 15216:2022-03","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(50,0 – 2000) mg/l"}],"search_zh":"水、废水 溶解性总固体（TDS） 重量法 范围 PN-EN 15216:2022-03","technique_zh":"重量法","test_object_zh":"水、废水","methodology_zh":"溶解性总固体（TDS）"},{"_id":"6a836e34af14b9c0e7b1e85e","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(5,0 – 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (5,0 – 1000) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":"Pracownia w Rzeszowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu Kjeldahla\nZakres (5,0 – 1000) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Woda, scieki Stezenie azotu Kjeldahla\nZakres (5,0 – 1000) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(5,0 – 1000) mg/l"}],"search_en":"Water, wastewater Kjeldahl nitrogen concentration Titrimetric method Range PN-EN 25663:2001","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(5,0 – 1000) mg/l"}],"search_zh":"水、废水 凯氏氮浓度 滴定法 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"水、废水"},{"_id":"6a836e34af14b9c0e7b1e85f","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(0,30 – 20,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (0,30 – 20,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 25663:2001 | PN-ISO 7150-1:2002","norm_bases":["PN-EN 25663:2001","PN-ISO 7150-1:2002"],"lab_section":"Pracownia w Rzeszowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu Kjeldahla\nZakres (0,30 – 20,0) mg/l\nMetoda spektrofotometryczna PN-EN 25663:2001 | PN-ISO 7150-1:2002 Woda, scieki Stezenie azotu Kjeldahla\nZakres (0,30 – 20,0) mg/l\nMetoda spektrofotometryczna PN-EN 25663:2001 | PN-ISO 7150-1:2002","categories":["water"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,30 – 20,0) mg/l"}],"search_en":"Water, wastewater Kjeldahl nitrogen concentration Spectrophotometric method Range PN-EN 25663:2001 | PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(0,30 – 20,0) mg/l"}],"search_zh":"水、废水 凯氏氮浓度 分光光度法 范围 PN-EN 25663:2001 | PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a836e34af14b9c0e7b1e860","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie metali","parameters":[{"name":"Al","range":"(0,100 – 100) mg/l"},{"name":"As","range":"(0,100– 10,0) mg/l"},{"name":"B","range":"(0,50 - 100) mg/l"},{"name":"Ba","range":"(0,0020 – 250) mg/l"},{"name":"Ca","range":"(2,50– 1 000) mg/l"},{"name":"Cd","range":"(0,0040 – 10,0) mg/l"},{"name":"Co","range":"(0,0150 – 25,0) mg/l"},{"name":"Cr","range":"(0,050 – 100) mg/l"},{"name":"Cu","range":"(0,050 – 100) mg/l"},{"name":"Fe","range":"(0,050 – 100) mg/l"},{"name":"K","range":"(0,50 -100) mg/l"},{"name":"Mg","range":"(1,00 – 1 000) mg/l"},{"name":"Mn","range":"(0,050 – 100) mg/l"},{"name":"Mo","range":"(0,050 – 25,0) mg/l"},{"name":"Na","range":"(1,00 – 1 000) mg/l"},{"name":"Ni","range":"(0,0100 – 100) mg/l"},{"name":"Pb","range":"(0,050 – 100) mg/l"},{"name":"Sb","range":"(0,100 – 10,0) mg/l"},{"name":"Se","range":"(0,100– 10,0) mg/l"},{"name":"Sn","range":"(0,100 – 25,0) mg/l"},{"name":"Tl","range":"(0,100 – 10,0) mg/l"},{"name":"V","range":"(0,0150 – 25,0) mg/l"},{"name":"Zn","range":"(0,0100 – 200) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie metali\nZakres:\nAl (0,100 – 100) mg/l\nAs (0,100– 10,0) mg/l\nB (0,50 - 100) mg/l\nBa (0,0020 – 250) mg/l\nCa (2,50– 1 000) mg/l\nCd (0,0040 – 10,0) mg/l\nCo (0,0150 – 25,0) mg/l\nCr (0,050 – 100) mg/l\nCu (0,050 – 100) mg/l\nFe (0,050 – 100) mg/l\nK (0,50 -100) mg/l\nMg (1,00 – 1 000) mg/l\nMn (0,050 – 100) mg/l\nMo (0,050 – 25,0) mg/l\nNa (1,00 – 1 000) mg/l\nNi (0,0100 – 100) mg/l\nPb (0,050 – 100) mg/l\nSb (0,100 – 10,0) mg/l\nSe (0,100– 10,0) mg/l\nSn (0,100 – 25,0) mg/l\nTl (0,100 – 10,0) mg/l\nV (0,0150 – 25,0) mg/l\nZn (0,0100 – 200) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":"Pracownia w Rzeszowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie metali\nZakres:\nAl (0,100 – 100) mg/l\nAs (0,100– 10,0) mg/l\nB (0,50 - 100) mg/l\nBa (0,0020 – 250) mg/l\nCa (2,50– 1 000) mg/l\nCd (0,0040 – 10,0) mg/l\nCo (0,0150 – 25,0) mg/l\nCr (0,050 – 100) mg/l\nCu (0,050 – 100) mg/l\nFe (0,050 – 100) mg/l\nK (0,50 -100) mg/l\nMg (1,00 – 1 000) mg/l\nMn (0,050 – 100) mg/l\nMo (0,050 – 25,0) mg/l\nNa (1,00 – 1 000) mg/l\nNi (0,0100 – 100) mg/l\nPb (0,050 – 100) mg/l\nSb (0,100 – 10,0) mg/l\nSe (0,100– 10,0) mg/l\nSn (0,100 – 25,0) mg/l\nTl (0,100 – 10,0) mg/l\nV (0,0150 – 25,0) mg/l\nZn (0,0100 – 200) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Woda, scieki Stezenie metali\nZakres:\nAl (0,100 – 100) mg/l\nAs (0,100– 10,0) mg/l\nB (0,50 - 100) mg/l\nBa (0,0020 – 250) mg/l\nCa (2,50– 1 000) mg/l\nCd (0,0040 – 10,0) mg/l\nCo (0,0150 – 25,0) mg/l\nCr (0,050 – 100) mg/l\nCu (0,050 – 100) mg/l\nFe (0,050 – 100) mg/l\nK (0,50 -100) mg/l\nMg (1,00 – 1 000) mg/l\nMn (0,050 – 100) mg/l\nMo (0,050 – 25,0) mg/l\nNa (1,00 – 1 000) mg/l\nNi (0,0100 – 100) mg/l\nPb (0,050 – 100) mg/l\nSb (0,100 – 10,0) mg/l\nSe (0,100– 10,0) mg/l\nSn (0,100 – 25,0) mg/l\nTl (0,100 – 10,0) mg/l\nV (0,0150 – 25,0) mg/l\nZn (0,0100 – 200) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["water","materials"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Metal concentrations","parameters_en":[{"name":"Al","range":"(0,100 – 100) mg/l"},{"name":"As","range":"(0,100– 10,0) mg/l"},{"name":"B","range":"(0,50 - 100) mg/l"},{"name":"Ba","range":"(0,0020 – 250) mg/l"},{"name":"Ca","range":"(2,50– 1 000) mg/l"},{"name":"Cd","range":"(0,0040 – 10,0) mg/l"},{"name":"Co","range":"(0,0150 – 25,0) mg/l"},{"name":"Cr","range":"(0,050 – 100) mg/l"},{"name":"Cu","range":"(0,050 – 100) mg/l"},{"name":"Fe","range":"(0,050 – 100) mg/l"},{"name":"K","range":"(0,50 -100) mg/l"},{"name":"Mg","range":"(1,00 – 1 000) mg/l"},{"name":"Mn","range":"(0,050 – 100) mg/l"},{"name":"Mo","range":"(0,050 – 25,0) mg/l"},{"name":"Na","range":"(1,00 – 1 000) mg/l"},{"name":"Ni","range":"(0,0100 – 100) mg/l"},{"name":"Pb","range":"(0,050 – 100) mg/l"},{"name":"Sb","range":"(0,100 – 10,0) mg/l"},{"name":"Se","range":"(0,100– 10,0) mg/l"},{"name":"Sn","range":"(0,100 – 25,0) mg/l"},{"name":"Tl","range":"(0,100 – 10,0) mg/l"},{"name":"V","range":"(0,0150 – 25,0) mg/l"},{"name":"Zn","range":"(0,0100 – 200) mg/l"}],"search_en":"Water, wastewater Metal concentrations Inductively coupled plasma optical emission spectrometry (ICP-OES) Al As B Ba Ca Cd Co Cr Cu Fe K Mg Mn Mo Na Ni Pb Sb Se Sn Tl V Zn PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Water, wastewater","methodology_zh":"金属浓度","parameters_zh":[{"name":"Al","range":"(0,100 – 100) mg/l"},{"name":"As","range":"(0,100– 10,0) mg/l"},{"name":"B","range":"(0,50 - 100) mg/l"},{"name":"Ba","range":"(0,0020 – 250) mg/l"},{"name":"Ca","range":"(2,50– 1 000) mg/l"},{"name":"Cd","range":"(0,0040 – 10,0) mg/l"},{"name":"Co","range":"(0,0150 – 25,0) mg/l"},{"name":"Cr","range":"(0,050 – 100) mg/l"},{"name":"Cu","range":"(0,050 – 100) mg/l"},{"name":"Fe","range":"(0,050 – 100) mg/l"},{"name":"K","range":"(0,50 -100) mg/l"},{"name":"Mg","range":"(1,00 – 1 000) mg/l"},{"name":"Mn","range":"(0,050 – 100) mg/l"},{"name":"Mo","range":"(0,050 – 25,0) mg/l"},{"name":"Na","range":"(1,00 – 1 000) mg/l"},{"name":"Ni","range":"(0,0100 – 100) mg/l"},{"name":"Pb","range":"(0,050 – 100) mg/l"},{"name":"Sb","range":"(0,100 – 10,0) mg/l"},{"name":"Se","range":"(0,100– 10,0) mg/l"},{"name":"Sn","range":"(0,100 – 25,0) mg/l"},{"name":"Tl","range":"(0,100 – 10,0) mg/l"},{"name":"V","range":"(0,0150 – 25,0) mg/l"},{"name":"Zn","range":"(0,0100 – 200) mg/l"}],"search_zh":"水、废水 金属浓度 电感耦合等离子体原子发射光谱法（ICP-OES） Al As B Ba Ca Cd Co Cr Cu Fe K Mg Mn Mo Na Ni Pb Sb Se Sn Tl V Zn PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"水、废水"},{"_id":"6a836e34af14b9c0e7b1e861","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Gleba","methodology":"Sucha masa / zawartość wody","parameters":[{"name":"Zakres","range":"(60,0 – 100) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha masa / zawartość wody\nZakres (60,0 – 100) %\nMetoda wagowa","reference":"PN-EN ISO 11465:2026-03 metoda A","norm_bases":["PN-EN ISO 11465:2026-03 metoda A"],"lab_section":"Pracownia w Rzeszowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Sucha masa / zawartość wody\nZakres (60,0 – 100) %\nMetoda wagowa PN-EN ISO 11465:2026-03 metoda A Gleba Sucha masa / zawartosc wody\nZakres (60,0 – 100) %\nMetoda wagowa PN-EN ISO 11465:2026-03 metoda A","categories":["water","environment"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry matter / water content","parameters_en":[{"name":"Range","range":"(60,0 – 100) %"}],"search_en":"Soil Dry matter / water content Gravimetric method Range PN-EN ISO 11465:2026-03 metoda A","technique_en":"Gravimetric method","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"(60,0 – 100) %"}],"search_zh":"土壤 干物质 / 水分含量 重量法 范围 PN-EN ISO 11465:2026-03 metoda A","technique_zh":"重量法","test_object_zh":"土壤","methodology_zh":"干物质 / 水分含量"},{"_id":"6a836e34af14b9c0e7b1e862","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Gleba","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":"Pracownia w Rzeszowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 Gleba pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["environment"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"search_en":"Soil pH Potentiometric method Range PN-EN ISO 10390:2022-09","technique_en":"Potentiometric method","test_object_en":"Soil","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"土壤 pH 值 电位法 范围 PN-EN ISO 10390:2022-09","technique_zh":"电位法","test_object_zh":"土壤"},{"_id":"6a836e34af14b9c0e7b1e863","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość metali","parameters":[{"name":"As","range":"(2,5 – 75) mg/kg"},{"name":"Ba","range":"(2,5 – 900) mg/kg"},{"name":"Co","range":"(2,5 – 8,0) mg/kg"},{"name":"Mo","range":"(2,5 – 10,0) mg/kg"},{"name":"Cd","range":"(0,40 – 3,0) mg/kg"},{"name":"Cr","range":"(2,5 – 100) mg/kg"},{"name":"Cu","range":"(2,5 – 250) mg/kg"},{"name":"Ni","range":"(2,5 – 75) mg/kg"},{"name":"Pb","range":"(2,5 – 450) mg/kg"},{"name":"Zn","range":"(2,5 – 800) mg/kg"},{"name":"Sn","range":"(2,5 – 30) mg/kg"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość metali\nZakres:\nAs (2,5 – 75) mg/kg\nBa (2,5 – 900) mg/kg\nCo (2,5 – 8,0) mg/kg\nMo (2,5 – 10,0) mg/kg\nCd (0,40 – 3,0) mg/kg\nCr (2,5 – 100) mg/kg\nCu (2,5 – 250) mg/kg\nNi (2,5 – 75) mg/kg\nPb (2,5 – 450) mg/kg\nZn (2,5 – 800) mg/kg\nSn (2,5 – 30) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PB-86/RZ wydanie 1 z dnia 02.03.2020 r.","norm_bases":["PB-86/RZ wydanie 1 z dnia 02.03.2020 r."],"lab_section":"Pracownia w Rzeszowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość metali\nZakres:\nAs (2,5 – 75) mg/kg\nBa (2,5 – 900) mg/kg\nCo (2,5 – 8,0) mg/kg\nMo (2,5 – 10,0) mg/kg\nCd (0,40 – 3,0) mg/kg\nCr (2,5 – 100) mg/kg\nCu (2,5 – 250) mg/kg\nNi (2,5 – 75) mg/kg\nPb (2,5 – 450) mg/kg\nZn (2,5 – 800) mg/kg\nSn (2,5 – 30) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PB-86/RZ wydanie 1 z dnia 02.03.2020 r. Gleba Zawartosc metali\nZakres:\nAs (2,5 – 75) mg/kg\nBa (2,5 – 900) mg/kg\nCo (2,5 – 8,0) mg/kg\nMo (2,5 – 10,0) mg/kg\nCd (0,40 – 3,0) mg/kg\nCr (2,5 – 100) mg/kg\nCu (2,5 – 250) mg/kg\nNi (2,5 – 75) mg/kg\nPb (2,5 – 450) mg/kg\nZn (2,5 – 800) mg/kg\nSn (2,5 – 30) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PB-86/RZ wydanie 1 z dnia 02.03.2020 r.","categories":["materials","environment"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Metal content","parameters_en":[{"name":"As","range":"(2,5 – 75) mg/kg"},{"name":"Ba","range":"(2,5 – 900) mg/kg"},{"name":"Co","range":"(2,5 – 8,0) mg/kg"},{"name":"Mo","range":"(2,5 – 10,0) mg/kg"},{"name":"Cd","range":"(0,40 – 3,0) mg/kg"},{"name":"Cr","range":"(2,5 – 100) mg/kg"},{"name":"Cu","range":"(2,5 – 250) mg/kg"},{"name":"Ni","range":"(2,5 – 75) mg/kg"},{"name":"Pb","range":"(2,5 – 450) mg/kg"},{"name":"Zn","range":"(2,5 – 800) mg/kg"},{"name":"Sn","range":"(2,5 – 30) mg/kg"}],"search_en":"Soil Metal content Inductively coupled plasma optical emission spectrometry (ICP-OES) As Ba Co Mo Cd Cr Cu Ni Pb Zn Sn PB-86/RZ wydanie 1 z dnia 02.03.2020 r.","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Soil","parameters_zh":[{"name":"As","range":"(2,5 – 75) mg/kg"},{"name":"Ba","range":"(2,5 – 900) mg/kg"},{"name":"Co","range":"(2,5 – 8,0) mg/kg"},{"name":"Mo","range":"(2,5 – 10,0) mg/kg"},{"name":"Cd","range":"(0,40 – 3,0) mg/kg"},{"name":"Cr","range":"(2,5 – 100) mg/kg"},{"name":"Cu","range":"(2,5 – 250) mg/kg"},{"name":"Ni","range":"(2,5 – 75) mg/kg"},{"name":"Pb","range":"(2,5 – 450) mg/kg"},{"name":"Zn","range":"(2,5 – 800) mg/kg"},{"name":"Sn","range":"(2,5 – 30) mg/kg"}],"search_zh":"土壤 金属含量 电感耦合等离子体原子发射光谱法（ICP-OES） As Ba Co Mo Cd Cr Cu Ni Pb Zn Sn PB-86/RZ wydanie 1 z dnia 02.03.2020 r.","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"土壤","methodology_zh":"金属含量"},{"_id":"6a836e34af14b9c0e7b1e864","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość ogólnego węgla organicznego (TOC)","parameters":[{"name":"Zakres","range":"(0,30 – 25) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją w zakresie podczerwieni IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją w zakresie podczerwieni IR"],"computed":[],"activity":"Zawartość ogólnego węgla organicznego (TOC)\nZakres (0,30 – 25) %\nMetoda wysokotemperaturowego spalania z detekcją w zakresie podczerwieni IR","reference":"PN-ISO 10694:2002","norm_bases":["PN-ISO 10694:2002"],"lab_section":"Pracownia w Rzeszowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość ogólnego węgla organicznego (TOC)\nZakres (0,30 – 25) %\nMetoda wysokotemperaturowego spalania z detekcją w zakresie podczerwieni IR PN-ISO 10694:2002 Gleba Zawartosc ogolnego wegla organicznego (TOC)\nZakres (0,30 – 25) %\nMetoda wysokotemperaturowego spalania z detekcja w zakresie podczerwieni IR PN-ISO 10694:2002","categories":["environment"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total organic carbon (TOC) content","parameters_en":[{"name":"Range","range":"(0,30 – 25) %"}],"search_en":"Soil Total organic carbon (TOC) content High-temperature combustion with infrared IR detection Range PN-ISO 10694:2002","technique_en":"High-temperature combustion with infrared IR detection","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"(0,30 – 25) %"}],"search_zh":"土壤 总有机碳（TOC）含量 高温燃烧-红外（IR）检测法 范围 PN-ISO 10694:2002","test_object_zh":"土壤","methodology_zh":"总有机碳（TOC）含量","technique_zh":"高温燃烧-红外（IR）检测法"},{"_id":"6a836e34af14b9c0e7b1e865","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość oleju mineralego (węglowodory C12-C35, C10-C40)","parameters":[{"name":"Zakres","range":"(10 – 1000) mg/kg"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość oleju mineralego (węglowodory C12-C35, C10-C40)\nZakres (10 – 1000) mg/kg\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PB-85/RZ wydanie 2 z dnia 22.05.2020 r.","norm_bases":["PB-85/RZ wydanie 2 z dnia 22.05.2020 r."],"lab_section":"Pracownia w Rzeszowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość oleju mineralego (węglowodory C12-C35, C10-C40)\nZakres (10 – 1000) mg/kg\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PB-85/RZ wydanie 2 z dnia 22.05.2020 r. Gleba Zawartosc oleju mineralego (weglowodory C12-C35, C10-C40)\nZakres (10 – 1000) mg/kg\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PB-85/RZ wydanie 2 z dnia 22.05.2020 r.","categories":["environment","petro"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mineral oil content (C12-C35, C10-C40 hydrocarbons)","parameters_en":[{"name":"Range","range":"(10 – 1000) mg/kg"}],"search_en":"Soil Mineral oil content (C12-C35, C10-C40 hydrocarbons) Gas chromatography with flame ionization detection (GC-FID) Range PB-85/RZ wydanie 2 z dnia 22.05.2020 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"(10 – 1000) mg/kg"}],"search_zh":"土壤 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PB-85/RZ wydanie 2 z dnia 22.05.2020 r.","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"土壤"},{"_id":"6a836e34af14b9c0e7b1e866","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Gleba","methodology":"Obecność i liczba żywych jaj pasożytów jelitowych Ascaris sp., Trichuris sp., Toxocara sp.","parameters":[],"technique":"Metoda flotacyjno-mikroskopowa","techniques":["Metoda flotacyjno-mikroskopowa"],"computed":[],"activity":"Obecność i liczba żywych jaj pasożytów jelitowych Ascaris sp., Trichuris sp., Toxocara sp.\nMetoda flotacyjno-mikroskopowa","reference":"PN-Z-19005:2018-10","norm_bases":["PN-Z-19005:2018-10"],"lab_section":"Pracownia w Rzeszowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Obecność i liczba żywych jaj pasożytów jelitowych Ascaris sp., Trichuris sp., Toxocara sp.\nMetoda flotacyjno-mikroskopowa PN-Z-19005:2018-10 Gleba Obecnosc i liczba zywych jaj pasozytow jelitowych Ascaris sp., Trichuris sp., Toxocara sp.\nMetoda flotacyjno-mikroskopowa PN-Z-19005:2018-10","categories":["environment"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence and count of viable eggs of intestinal parasites Ascaris sp., Trichuris sp., Toxocara sp.","search_en":"Soil Presence and count of viable eggs of intestinal parasites Ascaris sp., Trichuris sp., Toxocara sp. Flotation-microscopic method PN-Z-19005:2018-10","technique_en":"Flotation-microscopic method","test_object_en":"Soil","search_zh":"土壤 浮选-显微镜法 PN-Z-19005:2018-10","test_object_zh":"土壤","technique_zh":"浮选-显微镜法"},{"_id":"6a836e34af14b9c0e7b1e867","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Gleba","methodology":"Obecność Salmonella spp. w 100 g","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność Salmonella spp. w 100 g\nMetoda hodowlana z potwierdzeniem biochemicznym","reference":"PN-EN ISO 6579-1:2017-04+A1:2020-09","norm_bases":["PN-EN ISO 6579-1:2017-04+A1:2020-09"],"lab_section":"Pracownia w Rzeszowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Obecność Salmonella spp. w 100 g\nMetoda hodowlana z potwierdzeniem biochemicznym PN-EN ISO 6579-1:2017-04+A1:2020-09 Gleba Obecnosc Salmonella spp. w 100 g\nMetoda hodowlana z potwierdzeniem biochemicznym PN-EN ISO 6579-1:2017-04+A1:2020-09","categories":["microbiology","environment"],"row_index":55,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of Salmonella spp. in 100 g","search_en":"Soil Presence of Salmonella spp. in 100 g Culture method with biochemical confirmation PN-EN ISO 6579-1:2017-04+A1:2020-09","technique_en":"Culture method with biochemical confirmation","test_object_en":"Soil","search_zh":"土壤 100 g 中沙门氏菌属（Salmonella spp.）的检出 培养法结合生化确认 PN-EN ISO 6579-1:2017-04+A1:2020-09","technique_zh":"培养法结合生化确认","test_object_zh":"土壤","methodology_zh":"100 g 中沙门氏菌属（Salmonella spp.）的检出"},{"_id":"6a836e34af14b9c0e7b1e868","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Odpady O kod: 01 04 09 10 01 01 10 09 03 10 12 03 17 01 02; 17 01 81 17 05 03; 17 05 04; 17 05 06 19 08 01 20 03 03","methodology":"Zawartość i stężenie metali","parameters":[{"name":"Se","range":"(1,00 – 100) mg/kg"},{"name":"Se","range":"(0,100 – 10,0) mg/l"},{"name":"Sb","range":"(1,00 – 100) mg/kg"},{"name":"Sb","range":"(0,100 – 10,0) mg/l"},{"name":"As","range":"(1,00 – 100) mg/kg"},{"name":"As","range":"(0,100– 10,0) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość i stężenie metali\nZakres:\nSe (1,00 – 100) mg/kg\nSe (0,100 – 10,0) mg/l\nSb (1,00 – 100) mg/kg\nSb (0,100 – 10,0) mg/l\nAs (1,00 – 100) mg/kg\nAs (0,100– 10,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009 | PN-EN 12457-2:2006 | PN-EN 12457-4:2006","norm_bases":["PN-EN ISO 11885:2009","PN-EN 12457-2:2006","PN-EN 12457-4:2006"],"lab_section":"Pracownia w Rzeszowie","lab_address":null,"regulatory_area":"O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Odpady O kod: 01 04 09 10 01 01 10 09 03 10 12 03 17 01 02; 17 01 81 17 05 03; 17 05 04; 17 05 06 19 08 01 20 03 03 Zawartość i stężenie metali\nZakres:\nSe (1,00 – 100) mg/kg\nSe (0,100 – 10,0) mg/l\nSb (1,00 – 100) mg/kg\nSb (0,100 – 10,0) mg/l\nAs (1,00 – 100) mg/kg\nAs (0,100– 10,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 | PN-EN 12457-2:2006 | PN-EN 12457-4:2006 Odpady O kod: 01 04 09 10 01 01 10 09 03 10 12 03 17 01 02; 17 01 81 17 05 03; 17 05 04; 17 05 06 19 08 01 20 03 03 Zawartosc i stezenie metali\nZakres:\nSe (1,00 – 100) mg/kg\nSe (0,100 – 10,0) mg/l\nSb (1,00 – 100) mg/kg\nSb (0,100 – 10,0) mg/l\nAs (1,00 – 100) mg/kg\nAs (0,100– 10,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009 | PN-EN 12457-2:2006 | PN-EN 12457-4:2006","categories":["materials","environment"],"row_index":56,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Metal content and concentration","parameters_en":[{"name":"Se","range":"(1,00 – 100) mg/kg"},{"name":"Se","range":"(0,100 – 10,0) mg/l"},{"name":"Sb","range":"(1,00 – 100) mg/kg"},{"name":"Sb","range":"(0,100 – 10,0) mg/l"},{"name":"As","range":"(1,00 – 100) mg/kg"},{"name":"As","range":"(0,100– 10,0) mg/l"}],"search_en":"Waste O code: 01 04 09 10 01 01 10 09 03 10 12 03 17 01 02; 17 01 81 17 05 03; 17 05 04; 17 05 06 19 08 01 20 03 03 Metal content and concentration Inductively coupled plasma optical emission spectrometry (ICP-OES) Se Se Sb Sb As As PN-EN ISO 11885:2009 | PN-EN 12457-2:2006 | PN-EN 12457-4:2006","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Waste O code: 01 04 09 10 01 01 10 09 03 10 12 03 17 01 02; 17 01 81 17 05 03; 17 05 04; 17 05 06 19 08 01 20 03 03","search_zh":"金属的含量与浓度 电感耦合等离子体原子发射光谱法（ICP-OES） Se Se Sb Sb As As PN-EN ISO 11885:2009 | PN-EN 12457-2:2006 | PN-EN 12457-4:2006","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","parameters_zh":[{"name":"Se","range":"(1,00 – 100) mg/kg"},{"name":"Se","range":"(0,100 – 10,0) mg/l"},{"name":"Sb","range":"(1,00 – 100) mg/kg"},{"name":"Sb","range":"(0,100 – 10,0) mg/l"},{"name":"As","range":"(1,00 – 100) mg/kg"},{"name":"As","range":"(0,100– 10,0) mg/l"}],"methodology_zh":"金属的含量与浓度"},{"_id":"6a836e34af14b9c0e7b1e869","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Odpady O) kod: 10 01 01 19 08 01 20 03 03","methodology":"Zawartość i stężenie anionów","parameters":[{"name":"Fluorki","range":"(1 – 1 000) mg/kg"},{"name":"Fluorki","range":"(0,1 – 100) mg/l"},{"name":"Chlorki","range":"(1 – 50 000) mg/kg"},{"name":"Chlorki","range":"(0,1 – 5000) mg/l"},{"name":"Siarczany","range":"(5 – 100 000) mg/kg"},{"name":"Siarczany","range":"(0,5 – 10000) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Zawartość i stężenie anionów\nZakres:\nFluorki (1 – 1 000) mg/kg\nFluorki (0,1 – 100) mg/l\nChlorki (1 – 50 000) mg/kg\nChlorki (0,1 – 5000) mg/l\nSiarczany (5 – 100 000) mg/kg\nSiarczany (0,5 – 10000) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012 | PN-EN 12457-2:2006 | PN-EN 12457-4:2006","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012","PN-EN 12457-2:2006","PN-EN 12457-4:2006"],"lab_section":"Pracownia w Rzeszowie","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015 poz. 1277). O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Odpady O) kod: 10 01 01 19 08 01 20 03 03 Zawartość i stężenie anionów\nZakres:\nFluorki (1 – 1 000) mg/kg\nFluorki (0,1 – 100) mg/l\nChlorki (1 – 50 000) mg/kg\nChlorki (0,1 – 5000) mg/l\nSiarczany (5 – 100 000) mg/kg\nSiarczany (0,5 – 10000) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 | PN-EN 12457-2:2006 | PN-EN 12457-4:2006 Odpady O) kod: 10 01 01 19 08 01 20 03 03 Zawartosc i stezenie anionow\nZakres:\nFluorki (1 – 1 000) mg/kg\nFluorki (0,1 – 100) mg/l\nChlorki (1 – 50 000) mg/kg\nChlorki (0,1 – 5000) mg/l\nSiarczany (5 – 100 000) mg/kg\nSiarczany (0,5 – 10000) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 | PN-EN 12457-2:2006 | PN-EN 12457-4:2006","categories":["environment"],"row_index":57,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content and concentration of anions","parameters_en":[{"name":"Fluorides","range":"(1 – 1 000) mg/kg"},{"name":"Fluorides","range":"(0,1 – 100) mg/l"},{"name":"Chlorides","range":"(1 – 50 000) mg/kg"},{"name":"Chlorides","range":"(0,1 – 5000) mg/l"},{"name":"Sulfates","range":"(5 – 100 000) mg/kg"},{"name":"Sulfates","range":"(0,5 – 10000) mg/l"}],"search_en":"Content and concentration of anions Ion chromatography with conductometric detection (IC-CD) Fluorides Fluorides Chlorides Chlorides Sulfates Sulfates PN-EN ISO 10304-1:2009+AC:2012 | PN-EN 12457-2:2006 | PN-EN 12457-4:2006","technique_en":"Ion chromatography with conductometric detection (IC-CD)","parameters_zh":[{"name":"氟化物","range":"(1 – 1 000) mg/kg"},{"name":"氟化物","range":"(0,1 – 100) mg/l"},{"name":"氯化物","range":"(1 – 50 000) mg/kg"},{"name":"氯化物","range":"(0,1 – 5000) mg/l"},{"name":"硫酸盐","range":"(5 – 100 000) mg/kg"},{"name":"硫酸盐","range":"(0,5 – 10000) mg/l"}],"search_zh":"离子色谱-电导检测法（IC-CD） 氟化物 氟化物 氯化物 氯化物 硫酸盐 硫酸盐 PN-EN ISO 10304-1:2009+AC:2012 | PN-EN 12457-2:2006 | PN-EN 12457-4:2006","technique_zh":"离子色谱-电导检测法（IC-CD）"},{"_id":"6a836e34af14b9c0e7b1e86a","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Odpady O) kod: 10 01 01, 10 01 02, 10 01 03 19 08 01, 19 08 02, 19 08 05 20 03 01, 20 03 03","methodology":"Całkowite substancje rozpuszczone (TDS)","parameters":[{"name":"Zakres","range":"(500 – 200 000) mg/kg"},{"name":"Zakres","range":"(50 – 20000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Całkowite substancje rozpuszczone (TDS)\nZakres:\nZakres (500 – 200 000) mg/kg\nZakres (50 – 20000) mg/l\nMetoda wagowa","reference":"PN-EN 15216:2022-03 | PN-EN 12457-2:2006 | PN-EN 12457-4:2006","norm_bases":["PN-EN 15216:2022-03","PN-EN 12457-2:2006","PN-EN 12457-4:2006"],"lab_section":"Pracownia w Rzeszowie","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015 poz. 1277). O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Odpady O) kod: 10 01 01, 10 01 02, 10 01 03 19 08 01, 19 08 02, 19 08 05 20 03 01, 20 03 03 Całkowite substancje rozpuszczone (TDS)\nZakres:\nZakres (500 – 200 000) mg/kg\nZakres (50 – 20000) mg/l\nMetoda wagowa PN-EN 15216:2022-03 | PN-EN 12457-2:2006 | PN-EN 12457-4:2006 Odpady O) kod: 10 01 01, 10 01 02, 10 01 03 19 08 01, 19 08 02, 19 08 05 20 03 01, 20 03 03 Calkowite substancje rozpuszczone (TDS)\nZakres:\nZakres (500 – 200 000) mg/kg\nZakres (50 – 20000) mg/l\nMetoda wagowa PN-EN 15216:2022-03 | PN-EN 12457-2:2006 | PN-EN 12457-4:2006","categories":["environment"],"row_index":58,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total dissolved solids (TDS)","parameters_en":[{"name":"Range","range":"(500 – 200 000) mg/kg"},{"name":"Range","range":"(50 – 20000) mg/l"}],"search_en":"Total dissolved solids (TDS) Gravimetric method Range Range PN-EN 15216:2022-03 | PN-EN 12457-2:2006 | PN-EN 12457-4:2006","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(500 – 200 000) mg/kg"},{"name":"范围","range":"(50 – 20000) mg/l"}],"search_zh":"溶解性总固体（TDS） 重量法 范围 范围 PN-EN 15216:2022-03 | PN-EN 12457-2:2006 | PN-EN 12457-4:2006","technique_zh":"重量法","methodology_zh":"溶解性总固体（TDS）"},{"_id":"6a836e34af14b9c0e7b1e86b","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Odpady O) kod: 10 01 01 20 03 03","methodology":"Zawartość oleju mineralnego (węglowodory C12-C35, C10-C40)","parameters":[{"name":"Zakres","range":"(50 – 1000) mg/kg"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość oleju mineralnego (węglowodory C12-C35, C10-C40)\nZakres (50 – 1000) mg/kg\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PB-85/RZ wydanie 2 z dnia 22.05.2020 r.","norm_bases":["PB-85/RZ wydanie 2 z dnia 22.05.2020 r."],"lab_section":"Pracownia w Rzeszowie","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015 poz. 1277). O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Odpady O) kod: 10 01 01 20 03 03 Zawartość oleju mineralnego (węglowodory C12-C35, C10-C40)\nZakres (50 – 1000) mg/kg\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PB-85/RZ wydanie 2 z dnia 22.05.2020 r. Odpady O) kod: 10 01 01 20 03 03 Zawartosc oleju mineralnego (weglowodory C12-C35, C10-C40)\nZakres (50 – 1000) mg/kg\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PB-85/RZ wydanie 2 z dnia 22.05.2020 r.","categories":["environment","petro"],"row_index":59,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mineral oil content (C12-C35, C10-C40 hydrocarbons)","parameters_en":[{"name":"Range","range":"(50 – 1000) mg/kg"}],"search_en":"Mineral oil content (C12-C35, C10-C40 hydrocarbons) Gas chromatography with flame ionization detection (GC-FID) Range PB-85/RZ wydanie 2 z dnia 22.05.2020 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","parameters_zh":[{"name":"范围","range":"(50 – 1000) mg/kg"}],"search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） 范围 PB-85/RZ wydanie 2 z dnia 22.05.2020 r.","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a836e34af14b9c0e7b1e86c","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"OdpadyO) kod: 01 04 09 10 01 01 10 09 03 10 12 03 10 11 05 17 01 02 17 01 81 17 05 03 17 05 04 17 05 06 19 01 12 19 08 01 20 03 03","methodology":"Zawartość i stężenie rozpuszczonego węgla organicznego (DOC)","parameters":[{"name":"Zakres","range":"(10 – 50 000) mg/kg"},{"name":"Zakres","range":"(1,0 – 5000) mg/l"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją w zakresie podczerwieni IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją w zakresie podczerwieni IR"],"computed":[],"activity":"Zawartość i stężenie rozpuszczonego węgla organicznego (DOC)\nZakres:\nZakres (10 – 50 000) mg/kg\nZakres (1,0 – 5000) mg/l\nMetoda wysokotemperaturowego spalania z detekcją w zakresie podczerwieni IR","reference":"PN-EN 1484:1999 | PN-EN 12457-2:2006 | PN-EN 12457-4:2006","norm_bases":["PN-EN 1484:1999","PN-EN 12457-2:2006","PN-EN 12457-4:2006"],"lab_section":"Pracownia w Rzeszowie","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015 poz. 1277). O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"OdpadyO) kod: 01 04 09 10 01 01 10 09 03 10 12 03 10 11 05 17 01 02 17 01 81 17 05 03 17 05 04 17 05 06 19 01 12 19 08 01 20 03 03 Zawartość i stężenie rozpuszczonego węgla organicznego (DOC)\nZakres:\nZakres (10 – 50 000) mg/kg\nZakres (1,0 – 5000) mg/l\nMetoda wysokotemperaturowego spalania z detekcją w zakresie podczerwieni IR PN-EN 1484:1999 | PN-EN 12457-2:2006 | PN-EN 12457-4:2006 OdpadyO) kod: 01 04 09 10 01 01 10 09 03 10 12 03 10 11 05 17 01 02 17 01 81 17 05 03 17 05 04 17 05 06 19 01 12 19 08 01 20 03 03 Zawartosc i stezenie rozpuszczonego wegla organicznego (DOC)\nZakres:\nZakres (10 – 50 000) mg/kg\nZakres (1,0 – 5000) mg/l\nMetoda wysokotemperaturowego spalania z detekcja w zakresie podczerwieni IR PN-EN 1484:1999 | PN-EN 12457-2:2006 | PN-EN 12457-4:2006","categories":["environment"],"row_index":60,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content and concentration of dissolved organic carbon (DOC)","parameters_en":[{"name":"Range","range":"(10 – 50 000) mg/kg"},{"name":"Range","range":"(1,0 – 5000) mg/l"}],"search_en":"Content and concentration of dissolved organic carbon (DOC) High-temperature combustion with infrared IR detection Range Range PN-EN 1484:1999 | PN-EN 12457-2:2006 | PN-EN 12457-4:2006","technique_en":"High-temperature combustion with infrared IR detection","parameters_zh":[{"name":"范围","range":"(10 – 50 000) mg/kg"},{"name":"范围","range":"(1,0 – 5000) mg/l"}],"search_zh":"高温燃烧-红外（IR）检测法 范围 范围 PN-EN 1484:1999 | PN-EN 12457-2:2006 | PN-EN 12457-4:2006","technique_zh":"高温燃烧-红外（IR）检测法"},{"_id":"6a836e34af14b9c0e7b1e86d","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Odpady O kod: 01 04 09 10 01 01 10 09 03 10 12 03 17 01 02, 17 01 81 17 05 03, 17 05 04, 17 05 06 19 08 01 20 03 03","methodology":"Zawartość i stężenie metali","parameters":[{"name":"Ba","range":"(0,020 – 2500) mg/kg"},{"name":"Ba","range":"(0,0020 – 250) mg/l"},{"name":"Cr, Cu","range":"(0,50 – 1000) mg/kg"},{"name":"Cr, Cu","range":"(0,050 – 100) mg/l"},{"name":"Cd","range":"(0,040 – 100) mg/kg"},{"name":"Cd","range":"(0,0040 – 10,0) mg/l"},{"name":"Ni","range":"(0,100 – 1 000) mg/kg"},{"name":"Ni","range":"(0,0100 – 100) mg/l"},{"name":"Pb","range":"(0,50 – 1 000) mg/kg"},{"name":"Pb","range":"(0,050 – 100) mg/l"},{"name":"Zn","range":"(0,100 – 2 000) mg/kg"},{"name":"Zn","range":"(0,0100 – 200) mg/l"},{"name":"Mo","range":"(0,50 – 250) mg/kg"},{"name":"Mo","range":"(0,050 – 25,0) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość i stężenie metali\nZakres:\nBa (0,020 – 2500) mg/kg\nBa (0,0020 – 250) mg/l\nCr, Cu (0,50 – 1000) mg/kg\nCr, Cu (0,050 – 100) mg/l\nCd (0,040 – 100) mg/kg\nCd (0,0040 – 10,0) mg/l\nNi (0,100 – 1 000) mg/kg\nNi (0,0100 – 100) mg/l\nPb (0,50 – 1 000) mg/kg\nPb (0,050 – 100) mg/l\nZn (0,100 – 2 000) mg/kg\nZn (0,0100 – 200) mg/l\nMo (0,50 – 250) mg/kg\nMo (0,050 – 25,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009 | PN-EN 12457-2:2006 | PN-EN 12457-4:2006","norm_bases":["PN-EN ISO 11885:2009","PN-EN 12457-2:2006","PN-EN 12457-4:2006"],"lab_section":"Pracownia w Rzeszowie","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015 poz. 1277). O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Odpady O kod: 01 04 09 10 01 01 10 09 03 10 12 03 17 01 02, 17 01 81 17 05 03, 17 05 04, 17 05 06 19 08 01 20 03 03 Zawartość i stężenie metali\nZakres:\nBa (0,020 – 2500) mg/kg\nBa (0,0020 – 250) mg/l\nCr, Cu (0,50 – 1000) mg/kg\nCr, Cu (0,050 – 100) mg/l\nCd (0,040 – 100) mg/kg\nCd (0,0040 – 10,0) mg/l\nNi (0,100 – 1 000) mg/kg\nNi (0,0100 – 100) mg/l\nPb (0,50 – 1 000) mg/kg\nPb (0,050 – 100) mg/l\nZn (0,100 – 2 000) mg/kg\nZn (0,0100 – 200) mg/l\nMo (0,50 – 250) mg/kg\nMo (0,050 – 25,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 | PN-EN 12457-2:2006 | PN-EN 12457-4:2006 Odpady O kod: 01 04 09 10 01 01 10 09 03 10 12 03 17 01 02, 17 01 81 17 05 03, 17 05 04, 17 05 06 19 08 01 20 03 03 Zawartosc i stezenie metali\nZakres:\nBa (0,020 – 2500) mg/kg\nBa (0,0020 – 250) mg/l\nCr, Cu (0,50 – 1000) mg/kg\nCr, Cu (0,050 – 100) mg/l\nCd (0,040 – 100) mg/kg\nCd (0,0040 – 10,0) mg/l\nNi (0,100 – 1 000) mg/kg\nNi (0,0100 – 100) mg/l\nPb (0,50 – 1 000) mg/kg\nPb (0,050 – 100) mg/l\nZn (0,100 – 2 000) mg/kg\nZn (0,0100 – 200) mg/l\nMo (0,50 – 250) mg/kg\nMo (0,050 – 25,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009 | PN-EN 12457-2:2006 | PN-EN 12457-4:2006","categories":["materials","environment"],"row_index":61,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Metal content and concentration","parameters_en":[{"name":"Ba","range":"(0,020 – 2500) mg/kg"},{"name":"Ba","range":"(0,0020 – 250) mg/l"},{"name":"Cr, Cu","range":"(0,50 – 1000) mg/kg"},{"name":"Cr, Cu","range":"(0,050 – 100) mg/l"},{"name":"Cd","range":"(0,040 – 100) mg/kg"},{"name":"Cd","range":"(0,0040 – 10,0) mg/l"},{"name":"Ni","range":"(0,100 – 1 000) mg/kg"},{"name":"Ni","range":"(0,0100 – 100) mg/l"},{"name":"Pb","range":"(0,50 – 1 000) mg/kg"},{"name":"Pb","range":"(0,050 – 100) mg/l"},{"name":"Zn","range":"(0,100 – 2 000) mg/kg"},{"name":"Zn","range":"(0,0100 – 200) mg/l"},{"name":"Mo","range":"(0,50 – 250) mg/kg"},{"name":"Mo","range":"(0,050 – 25,0) mg/l"}],"search_en":"Waste O code: 01 04 09 10 01 01 10 09 03 10 12 03 17 01 02, 17 01 81 17 05 03, 17 05 04, 17 05 06 19 08 01 20 03 03 Metal content and concentration Inductively coupled plasma optical emission spectrometry (ICP-OES) Ba Ba Cr, Cu Cr, Cu Cd Cd Ni Ni Pb Pb Zn Zn Mo Mo PN-EN ISO 11885:2009 | PN-EN 12457-2:2006 | PN-EN 12457-4:2006","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Waste O code: 01 04 09 10 01 01 10 09 03 10 12 03 17 01 02, 17 01 81 17 05 03, 17 05 04, 17 05 06 19 08 01 20 03 03","parameters_zh":[{"name":"Ba","range":"(0,020 – 2500) mg/kg"},{"name":"Ba","range":"(0,0020 – 250) mg/l"},{"name":"Cr, Cu","range":"(0,50 – 1000) mg/kg"},{"name":"Cr, Cu","range":"(0,050 – 100) mg/l"},{"name":"Cd","range":"(0,040 – 100) mg/kg"},{"name":"Cd","range":"(0,0040 – 10,0) mg/l"},{"name":"Ni","range":"(0,100 – 1 000) mg/kg"},{"name":"Ni","range":"(0,0100 – 100) mg/l"},{"name":"Pb","range":"(0,50 – 1 000) mg/kg"},{"name":"Pb","range":"(0,050 – 100) mg/l"},{"name":"Zn","range":"(0,100 – 2 000) mg/kg"},{"name":"Zn","range":"(0,0100 – 200) mg/l"},{"name":"Mo","range":"(0,50 – 250) mg/kg"},{"name":"Mo","range":"(0,050 – 25,0) mg/l"}],"search_zh":"金属的含量与浓度 电感耦合等离子体原子发射光谱法（ICP-OES） Ba Ba Cd Cd Ni Ni Pb Pb Zn Zn Mo Mo PN-EN ISO 11885:2009 | PN-EN 12457-2:2006 | PN-EN 12457-4:2006","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","methodology_zh":"金属的含量与浓度"},{"_id":"6a836e34af14b9c0e7b1e86e","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Odpady O) kod: 10 04 01 10 08 09 17 05 04 19 12 09 19 05 03","methodology":"Zawartość ogólnego węgla organicznego (TOC)","parameters":[{"name":"Zakres","range":"(0,30 – 25) %"},{"name":"Zakres","range":"(3000 – 250000) mg/kg"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją w zakresie podczerwieni IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją w zakresie podczerwieni IR"],"computed":[],"activity":"Zawartość ogólnego węgla organicznego (TOC)\nZakres:\nZakres (0,30 – 25) %\nZakres (3000 – 250000) mg/kg\nMetoda wysokotemperaturowego spalania z detekcją w zakresie podczerwieni IR","reference":"PB-98/RZ wydanie 1 z dnia 15.11.2023 r.","norm_bases":["PB-98/RZ wydanie 1 z dnia 15.11.2023 r."],"lab_section":"Pracownia w Rzeszowie","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015 poz. 1277). O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Odpady O) kod: 10 04 01 10 08 09 17 05 04 19 12 09 19 05 03 Zawartość ogólnego węgla organicznego (TOC)\nZakres:\nZakres (0,30 – 25) %\nZakres (3000 – 250000) mg/kg\nMetoda wysokotemperaturowego spalania z detekcją w zakresie podczerwieni IR PB-98/RZ wydanie 1 z dnia 15.11.2023 r. Odpady O) kod: 10 04 01 10 08 09 17 05 04 19 12 09 19 05 03 Zawartosc ogolnego wegla organicznego (TOC)\nZakres:\nZakres (0,30 – 25) %\nZakres (3000 – 250000) mg/kg\nMetoda wysokotemperaturowego spalania z detekcja w zakresie podczerwieni IR PB-98/RZ wydanie 1 z dnia 15.11.2023 r.","categories":["environment"],"row_index":62,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total organic carbon (TOC) content","parameters_en":[{"name":"Range","range":"(0,30 – 25) %"},{"name":"Range","range":"(3000 – 250000) mg/kg"}],"search_en":"Total organic carbon (TOC) content High-temperature combustion with infrared IR detection Range Range PB-98/RZ wydanie 1 z dnia 15.11.2023 r.","technique_en":"High-temperature combustion with infrared IR detection","parameters_zh":[{"name":"范围","range":"(0,30 – 25) %"},{"name":"范围","range":"(3000 – 250000) mg/kg"}],"search_zh":"总有机碳（TOC）含量 高温燃烧-红外（IR）检测法 范围 范围 PB-98/RZ wydanie 1 z dnia 15.11.2023 r.","methodology_zh":"总有机碳（TOC）含量","technique_zh":"高温燃烧-红外（IR）检测法"},{"_id":"6a836e34af14b9c0e7b1e86f","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Osady ściekowe Odpady O) kod: 01 04 09 10 01 01, 10 01 02, 10 01 03 10 02 02 10 09 03 10 12 03 17 01 02, 17 01 81 17 05 03, 17 05 04, 17 05 06 19 01 12, 19 08 05, 19 12 09","methodology":"Sucha pozostałość / zawartość wody","parameters":[{"name":"Zakres","range":"(10,0 – 90,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha pozostałość / zawartość wody\nZakres (10,0 – 90,0) %\nMetoda wagowa","reference":"PN-EN ISO 11465:2026-03 metoda A","norm_bases":["PN-EN ISO 11465:2026-03 metoda A"],"lab_section":"Pracownia w Rzeszowie","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2023 poz. 23), Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015 poz. 1277). O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Osady ściekowe Odpady O) kod: 01 04 09 10 01 01, 10 01 02, 10 01 03 10 02 02 10 09 03 10 12 03 17 01 02, 17 01 81 17 05 03, 17 05 04, 17 05 06 19 01 12, 19 08 05, 19 12 09 Sucha pozostałość / zawartość wody\nZakres (10,0 – 90,0) %\nMetoda wagowa PN-EN ISO 11465:2026-03 metoda A Osady sciekowe Odpady O) kod: 01 04 09 10 01 01, 10 01 02, 10 01 03 10 02 02 10 09 03 10 12 03 17 01 02, 17 01 81 17 05 03, 17 05 04, 17 05 06 19 01 12, 19 08 05, 19 12 09 Sucha pozostalosc / zawartosc wody\nZakres (10,0 – 90,0) %\nMetoda wagowa PN-EN ISO 11465:2026-03 metoda A","categories":["water","environment"],"row_index":63,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry residue / water content","parameters_en":[{"name":"Range","range":"(10,0 – 90,0) %"}],"search_en":"Dry residue / water content Gravimetric method Range PN-EN ISO 11465:2026-03 metoda A","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(10,0 – 90,0) %"}],"search_zh":"干残渣/水分含量 重量法 范围 PN-EN ISO 11465:2026-03 metoda A","technique_zh":"重量法","methodology_zh":"干残渣/水分含量"},{"_id":"6a836e34af14b9c0e7b1e870","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Osady ściekowe Odpady O) kod: 01 04 09 10 01 01, 10 01 02, 10 01 03 10 02 02 10 09 03 10 12 03 17 01 02, 17 01 81 17 05 03, 17 05 04, 17 05 06 19 01 12, 19 08 05 19 12 09","methodology":"Straty przy prażeniu suchej masy (LOI)","parameters":[{"name":"Zakres","range":"(5,0 – 90,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Straty przy prażeniu suchej masy (LOI)\nZakres (5,0 – 90,0) %\nMetoda wagowa","reference":"PN-EN 15935:2022-01","norm_bases":["PN-EN 15935:2022-01"],"lab_section":"Pracownia w Rzeszowie","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2023 poz. 23), Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015 poz. 1277). O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Osady ściekowe Odpady O) kod: 01 04 09 10 01 01, 10 01 02, 10 01 03 10 02 02 10 09 03 10 12 03 17 01 02, 17 01 81 17 05 03, 17 05 04, 17 05 06 19 01 12, 19 08 05 19 12 09 Straty przy prażeniu suchej masy (LOI)\nZakres (5,0 – 90,0) %\nMetoda wagowa PN-EN 15935:2022-01 Osady sciekowe Odpady O) kod: 01 04 09 10 01 01, 10 01 02, 10 01 03 10 02 02 10 09 03 10 12 03 17 01 02, 17 01 81 17 05 03, 17 05 04, 17 05 06 19 01 12, 19 08 05 19 12 09 Straty przy prazeniu suchej masy (LOI)\nZakres (5,0 – 90,0) %\nMetoda wagowa PN-EN 15935:2022-01","categories":["water","environment"],"row_index":64,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Loss on ignition of dry matter (LOI)","parameters_en":[{"name":"Range","range":"(5,0 – 90,0) %"}],"search_en":"Loss on ignition of dry matter (LOI) Gravimetric method Range PN-EN 15935:2022-01","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(5,0 – 90,0) %"}],"search_zh":"干物质烧失量（LOI） 重量法 范围 PN-EN 15935:2022-01","technique_zh":"重量法","methodology_zh":"干物质烧失量（LOI）"},{"_id":"6a836e34af14b9c0e7b1e871","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Osady ściekowe Odpady O) kod: 19 08 05","methodology":"Obecność i liczba żywych jaj pasożytów jelitowych Ascaris sp., Trichuris sp., Toxocara sp.","parameters":[],"technique":"Metoda flotacyjno-mikroskopowa","techniques":["Metoda flotacyjno-mikroskopowa"],"computed":[],"activity":"Obecność i liczba żywych jaj pasożytów jelitowych Ascaris sp., Trichuris sp., Toxocara sp.\nMetoda flotacyjno-mikroskopowa","reference":"PN-Z-19005:2018-10","norm_bases":["PN-Z-19005:2018-10"],"lab_section":"Pracownia w Rzeszowie","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2023 poz. 23). O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Osady ściekowe Odpady O) kod: 19 08 05 Obecność i liczba żywych jaj pasożytów jelitowych Ascaris sp., Trichuris sp., Toxocara sp.\nMetoda flotacyjno-mikroskopowa PN-Z-19005:2018-10 Osady sciekowe Odpady O) kod: 19 08 05 Obecnosc i liczba zywych jaj pasozytow jelitowych Ascaris sp., Trichuris sp., Toxocara sp.\nMetoda flotacyjno-mikroskopowa PN-Z-19005:2018-10","categories":["water","environment"],"row_index":65,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence and count of viable eggs of intestinal parasites Ascaris sp., Trichuris sp., Toxocara sp.","search_en":"Sewage sludge Waste O) code: 19 08 05 Presence and count of viable eggs of intestinal parasites Ascaris sp., Trichuris sp., Toxocara sp. Flotation-microscopic method PN-Z-19005:2018-10","technique_en":"Flotation-microscopic method","test_object_en":"Sewage sludge Waste O) code: 19 08 05","search_zh":"浮选-显微镜法 PN-Z-19005:2018-10","technique_zh":"浮选-显微镜法"},{"_id":"6a836e34af14b9c0e7b1e872","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Osady ściekowe Odpady O) kod: 19 08 05","methodology":"Obecność Salmonella spp. w 100 g","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność Salmonella spp. w 100 g\nMetoda hodowlana z potwierdzeniem biochemicznym","reference":"PN-EN ISO 6579-1:2017-04+A1:2020-09","norm_bases":["PN-EN ISO 6579-1:2017-04+A1:2020-09"],"lab_section":"Pracownia w Rzeszowie","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2023 poz. 23). O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Osady ściekowe Odpady O) kod: 19 08 05 Obecność Salmonella spp. w 100 g\nMetoda hodowlana z potwierdzeniem biochemicznym PN-EN ISO 6579-1:2017-04+A1:2020-09 Osady sciekowe Odpady O) kod: 19 08 05 Obecnosc Salmonella spp. w 100 g\nMetoda hodowlana z potwierdzeniem biochemicznym PN-EN ISO 6579-1:2017-04+A1:2020-09","categories":["water","environment","microbiology"],"row_index":66,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of Salmonella spp. in 100 g","search_en":"Sewage sludge Waste O) code: 19 08 05 Presence of Salmonella spp. in 100 g Culture method with biochemical confirmation PN-EN ISO 6579-1:2017-04+A1:2020-09","technique_en":"Culture method with biochemical confirmation","test_object_en":"Sewage sludge Waste O) code: 19 08 05","search_zh":"100 g 中沙门氏菌属（Salmonella spp.）的检出 培养法结合生化确认 PN-EN ISO 6579-1:2017-04+A1:2020-09","technique_zh":"培养法结合生化确认","methodology_zh":"100 g 中沙门氏菌属（Salmonella spp.）的检出"},{"_id":"6a836e34af14b9c0e7b1e873","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Osady ściekowe Odpady O) kod: 19 08 05","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":"Pracownia w Rzeszowie","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2023 poz. 23). O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Osady ściekowe Odpady O) kod: 19 08 05 pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 Osady sciekowe Odpady O) kod: 19 08 05 pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["water","environment"],"row_index":67,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"search_en":"Sewage sludge Waste O) code: 19 08 05 pH Potentiometric method Range PN-EN ISO 10390:2022-09","technique_en":"Potentiometric method","test_object_en":"Sewage sludge Waste O) code: 19 08 05","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"pH 值 电位法 范围 PN-EN ISO 10390:2022-09","technique_zh":"电位法"},{"_id":"6a836e34af14b9c0e7b1e874","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Osady ściekowe Odpady O) kod: 19 08 05","methodology":"Zawartość azotu amonowego","parameters":[{"name":"Zakres","range":"(0,100 – 3,00) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu amonowego\nZakres (0,100 – 3,00) %\nMetoda miareczkowa","reference":"PN-75/C-04576.15","norm_bases":["PN-75/C-04576.15"],"lab_section":"Pracownia w Rzeszowie","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2023 poz. 23). O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Osady ściekowe Odpady O) kod: 19 08 05 Zawartość azotu amonowego\nZakres (0,100 – 3,00) %\nMetoda miareczkowa PN-75/C-04576.15 Osady sciekowe Odpady O) kod: 19 08 05 Zawartosc azotu amonowego\nZakres (0,100 – 3,00) %\nMetoda miareczkowa PN-75/C-04576.15","categories":["water","environment"],"row_index":68,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen content","parameters_en":[{"name":"Range","range":"(0,100 – 3,00) %"}],"search_en":"Sewage sludge Waste O) code: 19 08 05 Ammonium nitrogen content Titrimetric method Range PN-75/C-04576.15","technique_en":"Titrimetric method","test_object_en":"Sewage sludge Waste O) code: 19 08 05","parameters_zh":[{"name":"范围","range":"(0,100 – 3,00) %"}],"search_zh":"氨氮含量 滴定法 范围 PN-75/C-04576.15","technique_zh":"滴定法","methodology_zh":"氨氮含量"},{"_id":"6a836e34af14b9c0e7b1e875","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Osady ściekowe Odpady O) kod: 19 08 05","methodology":"Zawartość azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(0,10 – 8,0) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu Kjeldahla\nZakres (0,10 – 8,0) %\nMetoda miareczkowa","reference":"PN-EN 16169:2012","norm_bases":["PN-EN 16169:2012"],"lab_section":"Pracownia w Rzeszowie","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2023 poz. 23). O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Osady ściekowe Odpady O) kod: 19 08 05 Zawartość azotu Kjeldahla\nZakres (0,10 – 8,0) %\nMetoda miareczkowa PN-EN 16169:2012 Osady sciekowe Odpady O) kod: 19 08 05 Zawartosc azotu Kjeldahla\nZakres (0,10 – 8,0) %\nMetoda miareczkowa PN-EN 16169:2012","categories":["water","environment"],"row_index":69,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen content","parameters_en":[{"name":"Range","range":"(0,10 – 8,0) %"}],"search_en":"Sewage sludge Waste O) code: 19 08 05 Kjeldahl nitrogen content Titrimetric method Range PN-EN 16169:2012","technique_en":"Titrimetric method","test_object_en":"Sewage sludge Waste O) code: 19 08 05","parameters_zh":[{"name":"范围","range":"(0,10 – 8,0) %"}],"search_zh":"凯氏氮含量 滴定法 范围 PN-EN 16169:2012","technique_zh":"滴定法","methodology_zh":"凯氏氮含量"},{"_id":"6a836e34af14b9c0e7b1e876","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Osady ściekowe Odpady O) kod: 19 08 05","methodology":"Zawartość metali","parameters":[{"name":"Cd","range":"(0,200 – 20,0) mg/kg"},{"name":"Cr","range":"(1,00 – 5000) mg/kg"},{"name":"Cu","range":"(1,00 – 4000) mg/kg"},{"name":"Ni","range":"(1,00 – 250) mg/kg"},{"name":"Pb","range":"(1,00 – 3000) mg/kg"},{"name":"Zn","range":"(1,00 – 10000) mg/kg"},{"name":"Ca","range":"(1,00 – 50) %"},{"name":"Mg","range":"(0,100 – 5,0) %"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość metali\nZakres:\nCd (0,200 – 20,0) mg/kg\nCr (1,00 – 5000) mg/kg\nCu (1,00 – 4000) mg/kg\nNi (1,00 – 250) mg/kg\nPb (1,00 – 3000) mg/kg\nZn (1,00 – 10000) mg/kg\nCa (1,00 – 50) %\nMg (0,100 – 5,0) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 54321:2021-07 | PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 54321:2021-07","PN-EN ISO 11885:2009"],"lab_section":"Pracownia w Rzeszowie","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2023 poz. 23). O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Osady ściekowe Odpady O) kod: 19 08 05 Zawartość metali\nZakres:\nCd (0,200 – 20,0) mg/kg\nCr (1,00 – 5000) mg/kg\nCu (1,00 – 4000) mg/kg\nNi (1,00 – 250) mg/kg\nPb (1,00 – 3000) mg/kg\nZn (1,00 – 10000) mg/kg\nCa (1,00 – 50) %\nMg (0,100 – 5,0) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 54321:2021-07 | PN-EN ISO 11885:2009 Osady sciekowe Odpady O) kod: 19 08 05 Zawartosc metali\nZakres:\nCd (0,200 – 20,0) mg/kg\nCr (1,00 – 5000) mg/kg\nCu (1,00 – 4000) mg/kg\nNi (1,00 – 250) mg/kg\nPb (1,00 – 3000) mg/kg\nZn (1,00 – 10000) mg/kg\nCa (1,00 – 50) %\nMg (0,100 – 5,0) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 54321:2021-07 | PN-EN ISO 11885:2009","categories":["water","materials","environment"],"row_index":70,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Metal content","parameters_en":[{"name":"Cd","range":"(0,200 – 20,0) mg/kg"},{"name":"Cr","range":"(1,00 – 5000) mg/kg"},{"name":"Cu","range":"(1,00 – 4000) mg/kg"},{"name":"Ni","range":"(1,00 – 250) mg/kg"},{"name":"Pb","range":"(1,00 – 3000) mg/kg"},{"name":"Zn","range":"(1,00 – 10000) mg/kg"},{"name":"Ca","range":"(1,00 – 50) %"},{"name":"Mg","range":"(0,100 – 5,0) %"}],"search_en":"Sewage sludge Waste O) code: 19 08 05 Metal content Inductively coupled plasma optical emission spectrometry (ICP-OES) Cd Cr Cu Ni Pb Zn Ca Mg PN-EN ISO 54321:2021-07 | PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Sewage sludge Waste O) code: 19 08 05","parameters_zh":[{"name":"Cd","range":"(0,200 – 20,0) mg/kg"},{"name":"Cr","range":"(1,00 – 5000) mg/kg"},{"name":"Cu","range":"(1,00 – 4000) mg/kg"},{"name":"Ni","range":"(1,00 – 250) mg/kg"},{"name":"Pb","range":"(1,00 – 3000) mg/kg"},{"name":"Zn","range":"(1,00 – 10000) mg/kg"},{"name":"Ca","range":"(1,00 – 50) %"},{"name":"Mg","range":"(0,100 – 5,0) %"}],"search_zh":"金属含量 电感耦合等离子体原子发射光谱法（ICP-OES） Cd Cr Cu Ni Pb Zn Ca Mg PN-EN ISO 54321:2021-07 | PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","methodology_zh":"金属含量"},{"_id":"6a836e34af14b9c0e7b1e877","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Osady ściekowe Odpady O) kod: 19 08 05","methodology":"Zawartość fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,05 – 20) % P2O5"},{"name":"Zakres","range":"(0,02 – 8,7) %"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość fosforu ogólnego\nZakres:\nZakres (0,05 – 20) % P2O5\nZakres (0,02 – 8,7) %\nMetoda spektrofotometryczna","reference":"PN-EN ISO 54321:2021-07 | PN-EN ISO 6878:2006 pkt 7+ Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 54321:2021-07","PN-EN ISO 6878:2006 pkt 7+ Ap1:2010+Ap2:2010"],"lab_section":"Pracownia w Rzeszowie","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2023 poz. 23). O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Osady ściekowe Odpady O) kod: 19 08 05 Zawartość fosforu ogólnego\nZakres:\nZakres (0,05 – 20) % P2O5\nZakres (0,02 – 8,7) %\nMetoda spektrofotometryczna PN-EN ISO 54321:2021-07 | PN-EN ISO 6878:2006 pkt 7+ Ap1:2010+Ap2:2010 Osady sciekowe Odpady O) kod: 19 08 05 Zawartosc fosforu ogolnego\nZakres:\nZakres (0,05 – 20) % P2O5\nZakres (0,02 – 8,7) %\nMetoda spektrofotometryczna PN-EN ISO 54321:2021-07 | PN-EN ISO 6878:2006 pkt 7+ Ap1:2010+Ap2:2010","categories":["water","environment"],"row_index":71,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total phosphorus content","parameters_en":[{"name":"Range","range":"(0,05 – 20) % P2O5"},{"name":"Range","range":"(0,02 – 8,7) %"}],"search_en":"Sewage sludge Waste O) code: 19 08 05 Total phosphorus content Spectrophotometric method Range Range PN-EN ISO 54321:2021-07 | PN-EN ISO 6878:2006 pkt 7+ Ap1:2010+Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Sewage sludge Waste O) code: 19 08 05","parameters_zh":[{"name":"范围","range":"(0,05 – 20) % P2O5"},{"name":"范围","range":"(0,02 – 8,7) %"}],"search_zh":"总磷含量 分光光度法 范围 范围 PN-EN ISO 54321:2021-07 | PN-EN ISO 6878:2006 pkt 7+ Ap1:2010+Ap2:2010","technique_zh":"分光光度法","methodology_zh":"总磷含量"},{"_id":"6a836e34af14b9c0e7b1e878","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu Kieldahla","parameters":[{"name":"Zakres","range":"(5,0 – 1 000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu Kieldahla\nZakres (5,0 – 1 000) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":"Pracownia w Jaśle","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu Kieldahla\nZakres (5,0 – 1 000) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Woda, scieki Stezenie azotu Kieldahla\nZakres (5,0 – 1 000) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":72,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(5,0 – 1 000) mg/l"}],"search_en":"Water, wastewater Kjeldahl nitrogen concentration Titrimetric method Range PN-EN 25663:2001","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(5,0 – 1 000) mg/l"}],"search_zh":"水、废水 滴定法 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"水、废水"},{"_id":"6a836e34af14b9c0e7b1e879","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu Kieldahla","parameters":[{"name":"Zakres","range":"(0,30 – 20,0) mg/l"}],"technique":"Metoda spektofotometryczna","techniques":["Metoda spektofotometryczna"],"computed":[],"activity":"Stężenie azotu Kieldahla\nZakres (0,30 – 20,0) mg/l\nMetoda spektofotometryczna","reference":"PN-EN 25663:2001 | PN-ISO 7150-1:2002","norm_bases":["PN-EN 25663:2001","PN-ISO 7150-1:2002"],"lab_section":"Pracownia w Jaśle","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu Kieldahla\nZakres (0,30 – 20,0) mg/l\nMetoda spektofotometryczna PN-EN 25663:2001 | PN-ISO 7150-1:2002 Woda, scieki Stezenie azotu Kieldahla\nZakres (0,30 – 20,0) mg/l\nMetoda spektofotometryczna PN-EN 25663:2001 | PN-ISO 7150-1:2002","categories":["water"],"row_index":73,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,30 – 20,0) mg/l"}],"search_en":"Water, wastewater Kjeldahl nitrogen concentration Spectrophotometric method Range PN-EN 25663:2001 | PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,30 – 20,0) mg/l"}],"search_zh":"水、废水 范围 PN-EN 25663:2001 | PN-ISO 7150-1:2002","test_object_zh":"水、废水"},{"_id":"6a836e34af14b9c0e7b1e87a","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,050 – 20,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,050 – 20,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Pracownia w Jaśle","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu amonowego\nZakres (0,050 – 20,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, scieki Stezenie azotu amonowego\nZakres (0,050 – 20,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":74,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,050 – 20,0) mg/l"}],"search_en":"Water, wastewater Ammonium nitrogen concentration Spectrophotometric method Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,050 – 20,0) mg/l"}],"search_zh":"水、废水 氨氮浓度 分光光度法 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a836e34af14b9c0e7b1e87b","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(3,00 – 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (3,00 – 1000) mg/l\nMetoda miareczkowa","reference":"PN-IS0 5664:2002","norm_bases":["PN-IS0 5664:2002"],"lab_section":"Pracownia w Jaśle","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu amonowego\nZakres (3,00 – 1000) mg/l\nMetoda miareczkowa PN-IS0 5664:2002 Woda, scieki Stezenie azotu amonowego\nZakres (3,00 – 1000) mg/l\nMetoda miareczkowa PN-IS0 5664:2002","categories":["water"],"row_index":75,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(3,00 – 1000) mg/l"}],"search_en":"Water, wastewater Ammonium nitrogen concentration Titrimetric method Range PN-IS0 5664:2002","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(3,00 – 1000) mg/l"}],"search_zh":"水、废水 氨氮浓度 滴定法 范围 PN-IS0 5664:2002","technique_zh":"滴定法","test_object_zh":"水、废水"},{"_id":"6a836e34af14b9c0e7b1e87c","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,0020 – 10,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres (0,0020 – 10,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Pracownia w Jaśle","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu azotynowego\nZakres (0,0020 – 10,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, scieki Stezenie azotu azotynowego\nZakres (0,0020 – 10,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":76,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,0020 – 10,0) mg/l"}],"search_en":"Water, wastewater Nitrite nitrogen concentration Spectrophotometric method Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,0020 – 10,0) mg/l"}],"search_zh":"水、废水 亚硝态氮浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a836e34af14b9c0e7b1e87d","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu azotanowego","parameters":[{"name":"Zakres","range":"(0,050 – 100) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotanowego\nZakres (0,050 – 100) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":"Pracownia w Jaśle","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu azotanowego\nZakres (0,050 – 100) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08 Woda, scieki Stezenie azotu azotanowego\nZakres (0,050 – 100) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":77,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,050 – 100) mg/l"}],"search_en":"Water, wastewater Nitrate nitrogen concentration Spectrophotometric method Range PN-82/C-04576/08","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,050 – 100) mg/l"}],"search_zh":"水、废水 硝态氮浓度 分光光度法 范围 PN-82/C-04576/08","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a836e34af14b9c0e7b1e87e","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu ogólnego Suma NKjeld, NNO2 i NNO3 (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu ogólnego Suma NKjeld, NNO2 i NNO3 (z obliczeń)","reference":"PB-26/CLB Wydanie 1 z dnia 16.01.2026","norm_bases":["PB-26/CLB Wydanie 1 z dnia 16.01.2026"],"lab_section":"Pracownia w Jaśle","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu ogólnego Suma NKjeld, NNO2 i NNO3 (z obliczeń) PB-26/CLB Wydanie 1 z dnia 16.01.2026 Woda, scieki Stezenie azotu ogolnego Suma NKjeld, NNO2 i NNO3 (z obliczen) PB-26/CLB Wydanie 1 z dnia 16.01.2026","categories":["water"],"row_index":78,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Water, wastewater PB-26/CLB Wydanie 1 z dnia 16.01.2026","test_object_en":"Water, wastewater","search_zh":"水、废水 PB-26/CLB Wydanie 1 z dnia 16.01.2026","test_object_zh":"水、废水"},{"_id":"6a836e34af14b9c0e7b1e87f","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5, BZT 2+5","parameters":[{"name":"Zakres","range":"(0,5 – 6,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5, BZT 2+5\nZakres (0,5 – 6,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":"Pracownia w Jaśle","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu - BZT5, BZT 2+5\nZakres (0,5 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Woda, scieki Biochemiczne zapotrzebowanie tlenu - BZT5, BZT 2+5\nZakres (0,5 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":79,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,5 – 6,0) mg/l O2"}],"search_en":"Water, wastewater Electrochemical method Range PN-EN 1899-2:2002","technique_en":"Electrochemical method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,5 – 6,0) mg/l O2"}],"search_zh":"水、废水 电化学法 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"水、废水"},{"_id":"6a836e34af14b9c0e7b1e880","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5, BZT 2+5","parameters":[{"name":"Zakres","range":"(3 – 6000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5, BZT 2+5\nZakres (3 – 6000) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Pracownia w Jaśle","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu - BZT5, BZT 2+5\nZakres (3 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Woda, scieki Biochemiczne zapotrzebowanie tlenu - BZT5, BZT 2+5\nZakres (3 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":80,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(3 – 6000) mg/l O2"}],"search_en":"Water, wastewater Electrochemical method Range PN-EN ISO 5815-1:2019-12","technique_en":"Electrochemical method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(3 – 6000) mg/l O2"}],"search_zh":"水、废水 电化学法 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"水、废水"},{"_id":"6a836e34af14b9c0e7b1e881","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie fosforanów rozpuszczonych","parameters":[{"name":"Zakres","range":"(0,030 – 307) mg/l"},{"name":"Zakres","range":"(0,010 – 100) mg/l P"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforanów rozpuszczonych\nZakres:\nZakres (0,030 – 307) mg/l\nZakres (0,010 – 100) mg/l P\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 pkt 4+ Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 pkt 4+ Ap1:2010+Ap2:2010"],"lab_section":"Pracownia w Jaśle","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie fosforanów rozpuszczonych\nZakres:\nZakres (0,030 – 307) mg/l\nZakres (0,010 – 100) mg/l P\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt 4+ Ap1:2010+Ap2:2010 Woda, scieki Stezenie fosforanow rozpuszczonych\nZakres:\nZakres (0,030 – 307) mg/l\nZakres (0,010 – 100) mg/l P\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt 4+ Ap1:2010+Ap2:2010","categories":["water"],"row_index":81,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissolved phosphate concentration","parameters_en":[{"name":"Range","range":"(0,030 – 307) mg/l"},{"name":"Range","range":"(0,010 – 100) mg/l P"}],"search_en":"Water, wastewater Dissolved phosphate concentration Spectrophotometric method Range Range PN-EN ISO 6878:2006 pkt 4+ Ap1:2010+Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,030 – 307) mg/l"},{"name":"范围","range":"(0,010 – 100) mg/l P"}],"search_zh":"水、废水 溶解性磷酸盐浓度 分光光度法 范围 范围 PN-EN ISO 6878:2006 pkt 4+ Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"溶解性磷酸盐浓度"},{"_id":"6a836e34af14b9c0e7b1e882","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,025 – 100) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,025 – 100) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 pkt 7, 8 + Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 pkt 7, 8 + Ap1:2010+Ap2:2010"],"lab_section":"Pracownia w Jaśle","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie fosforu ogólnego\nZakres (0,025 – 100) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt 7, 8 + Ap1:2010+Ap2:2010 Woda, scieki Stezenie fosforu ogolnego\nZakres (0,025 – 100) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt 7, 8 + Ap1:2010+Ap2:2010","categories":["water"],"row_index":82,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,025 – 100) mg/l"}],"search_en":"Water, wastewater Total phosphorus concentration Spectrophotometric method Range PN-EN ISO 6878:2006 pkt 7, 8 + Ap1:2010+Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,025 – 100) mg/l"}],"search_zh":"水、废水 总磷浓度 分光光度法 范围 PN-EN ISO 6878:2006 pkt 7, 8 + Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a836e34af14b9c0e7b1e883","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Całkowite substancje rozpuszczone (TDS)","parameters":[{"name":"Zakres","range":"(50,0 – 2000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Całkowite substancje rozpuszczone (TDS)\nZakres (50,0 – 2000) mg/l\nMetoda wagowa","reference":"PN-EN 15216:2022-03","norm_bases":["PN-EN 15216:2022-03"],"lab_section":"Pracownia w Jaśle","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Całkowite substancje rozpuszczone (TDS)\nZakres (50,0 – 2000) mg/l\nMetoda wagowa PN-EN 15216:2022-03 Woda, scieki Calkowite substancje rozpuszczone (TDS)\nZakres (50,0 – 2000) mg/l\nMetoda wagowa PN-EN 15216:2022-03","categories":["water"],"row_index":83,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total dissolved solids (TDS)","parameters_en":[{"name":"Range","range":"(50,0 – 2000) mg/l"}],"search_en":"Water, wastewater Total dissolved solids (TDS) Gravimetric method Range PN-EN 15216:2022-03","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(50,0 – 2000) mg/l"}],"search_zh":"水、废水 溶解性总固体（TDS） 重量法 范围 PN-EN 15216:2022-03","technique_zh":"重量法","test_object_zh":"水、废水","methodology_zh":"溶解性总固体（TDS）"},{"_id":"6a836e34af14b9c0e7b1e884","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Zasadowość ogólna","parameters":[{"name":"Zakres","range":"(10,0 – 2000) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zasadowość ogólna\nZakres (10,0 – 2000) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-EN ISO 9963-1:2001 pkt 8.2 + Ap1:2004","norm_bases":["PN-EN ISO 9963-1:2001 pkt 8.2 + Ap1:2004"],"lab_section":"Pracownia w Jaśle","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Zasadowość ogólna\nZakres (10,0 – 2000) mg/l CaCO3\nMetoda miareczkowa PN-EN ISO 9963-1:2001 pkt 8.2 + Ap1:2004 Woda, scieki Zasadowosc ogolna\nZakres (10,0 – 2000) mg/l CaCO3\nMetoda miareczkowa PN-EN ISO 9963-1:2001 pkt 8.2 + Ap1:2004","categories":["water"],"row_index":84,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total alkalinity","parameters_en":[{"name":"Range","range":"(10,0 – 2000) mg/l CaCO3"}],"search_en":"Water, wastewater Total alkalinity Titrimetric method Range PN-EN ISO 9963-1:2001 pkt 8.2 + Ap1:2004","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(10,0 – 2000) mg/l CaCO3"}],"search_zh":"水、废水 总碱度 滴定法 范围 PN-EN ISO 9963-1:2001 pkt 8.2 + Ap1:2004","technique_zh":"滴定法","test_object_zh":"水、废水","methodology_zh":"总碱度"},{"_id":"6a836e34af14b9c0e7b1e885","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0 – 2000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 2000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007 + Ap1:2007","norm_bases":["PN-EN 872:2007 + Ap1:2007"],"lab_section":"Pracownia w Jaśle","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Zawiesiny ogólne\nZakres (2,0 – 2000) mg/l\nMetoda wagowa PN-EN 872:2007 + Ap1:2007 Woda, scieki Zawiesiny ogolne\nZakres (2,0 – 2000) mg/l\nMetoda wagowa PN-EN 872:2007 + Ap1:2007","categories":["water"],"row_index":85,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2,0 – 2000) mg/l"}],"search_en":"Water, wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007 + Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 2000) mg/l"}],"search_zh":"水、废水 总悬浮物 重量法 范围 PN-EN 872:2007 + Ap1:2007","technique_zh":"重量法","test_object_zh":"水、废水"},{"_id":"6a836e34af14b9c0e7b1e886","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie surfaktantów anionowych (substancji powierzchniowo czynnych anionowych)","parameters":[{"name":"Zakres","range":"(0,100 – 10,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie surfaktantów anionowych (substancji powierzchniowo czynnych anionowych)\nZakres (0,100 – 10,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 903:2002","norm_bases":["PN-EN 903:2002"],"lab_section":"Pracownia w Jaśle","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie surfaktantów anionowych (substancji powierzchniowo czynnych anionowych)\nZakres (0,100 – 10,0) mg/l\nMetoda spektrofotometryczna PN-EN 903:2002 Woda, scieki Stezenie surfaktantow anionowych (substancji powierzchniowo czynnych anionowych)\nZakres (0,100 – 10,0) mg/l\nMetoda spektrofotometryczna PN-EN 903:2002","categories":["water"],"row_index":86,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of anionic surfactants (anionic surface-active substances)","parameters_en":[{"name":"Range","range":"(0,100 – 10,0) mg/l"}],"search_en":"Water, wastewater Concentration of anionic surfactants (anionic surface-active substances) Spectrophotometric method Range PN-EN 903:2002","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,100 – 10,0) mg/l"}],"search_zh":"水、废水 分光光度法 范围 PN-EN 903:2002","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a836e34af14b9c0e7b1e887","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)","parameters":[{"name":"fluoranten","range":"(0,0010 – 3,0) µg/l"},{"name":"benzo(k)fluoranten","range":"(5,0 x10-5 – 1,0) µg/l"},{"name":"benzo(b)fluoranten","range":"(5,0 x10-5 – 1,0) µg/l"},{"name":"dibenzo(a,h)antracen","range":"(0,0010 – 1,0) µg/l"},{"name":"benzo(a)piren","range":"(5,0 x10-5 – 1,0) µg/l"},{"name":"benzo(g,h,i)perylen","range":"(5,0 x10-5 – 1,0) µg/l"},{"name":"indeno(1,2,3-c,d )piren","range":"(5,0 x10-5 – 1,0) µg/l"},{"name":"naftalen","range":"(0,080 – 10) µg/l"},{"name":"antracen","range":"(0,0010 – 1,0) µg/l"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)\nZakres:\nfluoranten (0,0010 – 3,0) µg/l\nbenzo(k)fluoranten (5,0 x10-5 – 1,0) µg/l\nbenzo(b)fluoranten (5,0 x10-5 – 1,0) µg/l\ndibenzo(a,h)antracen (0,0010 – 1,0) µg/l\nbenzo(a)piren (5,0 x10-5 – 1,0) µg/l\nbenzo(g,h,i)perylen (5,0 x10-5 – 1,0) µg/l\nindeno(1,2,3-c,d )piren (5,0 x10-5 – 1,0) µg/l\nnaftalen (0,080 – 10) µg/l\nantracen (0,0010 – 1,0) µg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"PN-EN ISO 17993:2005","norm_bases":["PN-EN ISO 17993:2005"],"lab_section":"Pracownia w Jaśle","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)\nZakres:\nfluoranten (0,0010 – 3,0) µg/l\nbenzo(k)fluoranten (5,0 x10-5 – 1,0) µg/l\nbenzo(b)fluoranten (5,0 x10-5 – 1,0) µg/l\ndibenzo(a,h)antracen (0,0010 – 1,0) µg/l\nbenzo(a)piren (5,0 x10-5 – 1,0) µg/l\nbenzo(g,h,i)perylen (5,0 x10-5 – 1,0) µg/l\nindeno(1,2,3-c,d )piren (5,0 x10-5 – 1,0) µg/l\nnaftalen (0,080 – 10) µg/l\nantracen (0,0010 – 1,0) µg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) PN-EN ISO 17993:2005 Woda, scieki Stezenie wielopierscieniowych weglowodorow aromatycznych (WWA)\nZakres:\nfluoranten (0,0010 – 3,0) µg/l\nbenzo(k)fluoranten (5,0 x10-5 – 1,0) µg/l\nbenzo(b)fluoranten (5,0 x10-5 – 1,0) µg/l\ndibenzo(a,h)antracen (0,0010 – 1,0) µg/l\nbenzo(a)piren (5,0 x10-5 – 1,0) µg/l\nbenzo(g,h,i)perylen (5,0 x10-5 – 1,0) µg/l\nindeno(1,2,3-c,d )piren (5,0 x10-5 – 1,0) µg/l\nnaftalen (0,080 – 10) µg/l\nantracen (0,0010 – 1,0) µg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) PN-EN ISO 17993:2005","categories":["water"],"row_index":87,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of polycyclic aromatic hydrocarbons (PAH)","parameters_en":[{"name":"fluoranthene","range":"(0,0010 – 3,0) µg/l"},{"name":"benzo(k)fluoranthene","range":"(5,0 x10-5 – 1,0) µg/l"},{"name":"benzo(b)fluoranthene","range":"(5,0 x10-5 – 1,0) µg/l"},{"name":"dibenzo(a,h)anthracene","range":"(0,0010 – 1,0) µg/l"},{"name":"benzo(a)pyrene","range":"(5,0 x10-5 – 1,0) µg/l"},{"name":"benzo(g,h,i)perylene","range":"(5,0 x10-5 – 1,0) µg/l"},{"name":"indeno(1,2,3-c,d )piren","range":"(5,0 x10-5 – 1,0) µg/l"},{"name":"naphthalene","range":"(0,080 – 10) µg/l"},{"name":"anthracene","range":"(0,0010 – 1,0) µg/l"}],"search_en":"Water, wastewater Concentration of polycyclic aromatic hydrocarbons (PAH) High-performance liquid chromatography with fluorescence detection (HPLC-FLD) fluoranthene benzo(k)fluoranthene benzo(b)fluoranthene dibenzo(a,h)anthracene benzo(a)pyrene benzo(g,h,i)perylene naphthalene anthracene PN-EN ISO 17993:2005","technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD)","test_object_en":"Water, wastewater","search_zh":"水、废水 多环芳烃（PAHs）浓度 高效液相色谱-荧光检测法（HPLC-FLD） 荧蒽 苯并（k）荧蒽 苯并（b）荧蒽 二苯并（a,h）蒽 苯并（a）芘 苯并(g,h,i)苝 萘 蒽 PN-EN ISO 17993:2005","technique_zh":"高效液相色谱-荧光检测法（HPLC-FLD）","test_object_zh":"水、废水","parameters_zh":[{"name":"荧蒽","range":"(0,0010 – 3,0) µg/l"},{"name":"苯并（k）荧蒽","range":"(5,0 x10-5 – 1,0) µg/l"},{"name":"苯并（b）荧蒽","range":"(5,0 x10-5 – 1,0) µg/l"},{"name":"二苯并（a,h）蒽","range":"(0,0010 – 1,0) µg/l"},{"name":"苯并（a）芘","range":"(5,0 x10-5 – 1,0) µg/l"},{"name":"苯并(g,h,i)苝","range":"(5,0 x10-5 – 1,0) µg/l"},{"name":"indeno(1,2,3-c,d )piren","range":"(5,0 x10-5 – 1,0) µg/l"},{"name":"萘","range":"(0,080 – 10) µg/l"},{"name":"蒽","range":"(0,0010 – 1,0) µg/l"}],"methodology_zh":"多环芳烃（PAHs）浓度"},{"_id":"6a836e34af14b9c0e7b1e888","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Suma wielopierścieniowych węglowodorów aromatycznych (WWA) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma wielopierścieniowych węglowodorów aromatycznych (WWA) (z obliczeń)","reference":"PN-EN ISO 17993:2005","norm_bases":["PN-EN ISO 17993:2005"],"lab_section":"Pracownia w Jaśle","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Suma wielopierścieniowych węglowodorów aromatycznych (WWA) (z obliczeń) PN-EN ISO 17993:2005 Woda, scieki Suma wielopierscieniowych weglowodorow aromatycznych (WWA) (z obliczen) PN-EN ISO 17993:2005","categories":["water"],"row_index":88,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of polycyclic aromatic hydrocarbons (PAH) (calculated)","search_en":"Water, wastewater Sum of polycyclic aromatic hydrocarbons (PAH) (calculated) PN-EN ISO 17993:2005","test_object_en":"Water, wastewater","search_zh":"水、废水 多环芳烃（PAH）总量（由计算得出） PN-EN ISO 17993:2005","test_object_zh":"水、废水","methodology_zh":"多环芳烃（PAH）总量（由计算得出）"},{"_id":"6a836e34af14b9c0e7b1e889","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Substancje organiczne ekstrahujące się eterem naftowym","parameters":[{"name":"Zakres","range":"(5,0 – 100) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Substancje organiczne ekstrahujące się eterem naftowym\nZakres (5,0 – 100) mg/l\nMetoda wagowa","reference":"PB-77/RZ Wydanie 1 z dnia 02.03.2020 r.","norm_bases":["PB-77/RZ Wydanie 1 z dnia 02.03.2020 r."],"lab_section":"Pracownia w Jaśle","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Substancje organiczne ekstrahujące się eterem naftowym\nZakres (5,0 – 100) mg/l\nMetoda wagowa PB-77/RZ Wydanie 1 z dnia 02.03.2020 r. Woda, scieki Substancje organiczne ekstrahujace sie eterem naftowym\nZakres (5,0 – 100) mg/l\nMetoda wagowa PB-77/RZ Wydanie 1 z dnia 02.03.2020 r.","categories":["water"],"row_index":89,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Organic substances extractable with petroleum ether","parameters_en":[{"name":"Range","range":"(5,0 – 100) mg/l"}],"search_en":"Water, wastewater Organic substances extractable with petroleum ether Gravimetric method Range PB-77/RZ Wydanie 1 z dnia 02.03.2020 r.","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(5,0 – 100) mg/l"}],"search_zh":"水、废水 石油醚可萃取有机物质 重量法 范围 PB-77/RZ Wydanie 1 z dnia 02.03.2020 r.","technique_zh":"重量法","test_object_zh":"水、废水","methodology_zh":"石油醚可萃取有机物质"},{"_id":"6a836e34af14b9c0e7b1e88a","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Indeks fenolowy","parameters":[{"name":"Zakres","range":"(0,0020 – 1,0) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Indeks fenolowy\nZakres (0,0020 – 1,0) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 14402:2004 pkt 4","norm_bases":["PN-EN ISO 14402:2004 pkt 4"],"lab_section":"Pracownia w Jaśle","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Indeks fenolowy\nZakres (0,0020 – 1,0) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 14402:2004 pkt 4 Woda, scieki Indeks fenolowy\nZakres (0,0020 – 1,0) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 14402:2004 pkt 4","categories":["water"],"row_index":90,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phenol index","parameters_en":[{"name":"Range","range":"(0,0020 – 1,0) mg/l"}],"search_en":"Water, wastewater Phenol index Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN ISO 14402:2004 pkt 4","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,0020 – 1,0) mg/l"}],"search_zh":"水、废水 酚指数 连续流动分析（CFA）分光光度检测法 范围 PN-EN ISO 14402:2004 pkt 4","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"水、废水","methodology_zh":"酚指数"},{"_id":"6a836e34af14b9c0e7b1e88b","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie cyjanków wolnych i cyjanków ogólnych","parameters":[{"name":"Zakres","range":"(0,0030 – 10,0) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie cyjanków wolnych i cyjanków ogólnych\nZakres (0,0030 – 10,0) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 14403-2:2012","norm_bases":["PN-EN ISO 14403-2:2012"],"lab_section":"Pracownia w Jaśle","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie cyjanków wolnych i cyjanków ogólnych\nZakres (0,0030 – 10,0) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 14403-2:2012 Woda, scieki Stezenie cyjankow wolnych i cyjankow ogolnych\nZakres (0,0030 – 10,0) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 14403-2:2012","categories":["water"],"row_index":91,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free cyanide and total cyanide concentration","parameters_en":[{"name":"Range","range":"(0,0030 – 10,0) mg/l"}],"search_en":"Water, wastewater Free cyanide and total cyanide concentration Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN ISO 14403-2:2012","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,0030 – 10,0) mg/l"}],"search_zh":"水、废水 连续流动分析（CFA）分光光度检测法 范围 PN-EN ISO 14403-2:2012","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"水、废水"},{"_id":"6a836e34af14b9c0e7b1e88c","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda","methodology":"Indeks nadmanganianowy","parameters":[{"name":"Zakres","range":"(0,80 – 100) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Indeks nadmanganianowy\nZakres (0,80 – 100) mg/l O2\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":"Pracownia w Jaśle","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Indeks nadmanganianowy\nZakres (0,80 – 100) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda Indeks nadmanganianowy\nZakres (0,80 – 100) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":92,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Permanganate index","parameters_en":[{"name":"Range","range":"(0,80 – 100) mg/l O2"}],"search_en":"Water Permanganate index Titrimetric method Range PN-EN ISO 8467:2001","technique_en":"Titrimetric method","test_object_en":"Water","methodology_zh":"高锰酸盐指数","parameters_zh":[{"name":"范围","range":"(0,80 – 100) mg/l O2"}],"search_zh":"水 高锰酸盐指数 滴定法 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"水"},{"_id":"6a836e34af14b9c0e7b1e88d","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)","parameters":[{"name":"Zakres","range":"(10,0 – 2000) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (10,0 – 2000) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":"Pracownia w Jaśle","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (10,0 – 2000) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999 Woda Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna)\nZakres (10,0 – 2000) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":93,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total content of calcium and magnesium (total hardness)","parameters_en":[{"name":"Range","range":"(10,0 – 2000) mg/l CaCO3"}],"search_en":"Water Total content of calcium and magnesium (total hardness) Titrimetric method Range PN-ISO 6059:1999","technique_en":"Titrimetric method","test_object_en":"Water","methodology_zh":"钙与镁总量（总硬度）","parameters_zh":[{"name":"范围","range":"(10,0 – 2000) mg/l CaCO3"}],"search_zh":"水 钙与镁总量（总硬度） 滴定法 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"水"},{"_id":"6a836e34af14b9c0e7b1e88e","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA)","parameters":[{"name":"naftalen","range":"(0,02 – 200) mg/kg"},{"name":"fenantren","range":"(0,02 – 200) mg/kg"},{"name":"antracen","range":"(0,01 – 200) mg/kg"},{"name":"fluoranten","range":"(0,01 – 200) mg/kg"},{"name":"chryzen","range":"(0,01 – 200) mg/kg"},{"name":"benzo(a)antracen","range":"(0,01 – 200) mg/kg"},{"name":"benzo(a)piren","range":"(0,01 – 200) mg/kg"},{"name":"benzo(g,h,i)perylen","range":"(0,01 – 200) mg/kg"},{"name":"benzo(a)fluoranten","range":"(0,01 – 1) mg/kg"},{"name":"dibenzo(a,h)antracen","range":"(0,01 – 200) mg/kg"},{"name":"benzo(b)fluoranten","range":"(0,01 – 200) mg/kg"},{"name":"benzo(k)fluoranten","range":"0,01 – 200) mg/kg"},{"name":"indeno(1,2,3-c,d)piren","range":"(0,01 – 200) mg/kg"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA)\nZakres:\nnaftalen (0,02 – 200) mg/kg\nfenantren (0,02 – 200) mg/kg\nantracen (0,01 – 200) mg/kg\nfluoranten (0,01 – 200) mg/kg\nchryzen (0,01 – 200) mg/kg\nbenzo(a)antracen (0,01 – 200) mg/kg\nbenzo(a)piren (0,01 – 200) mg/kg\nbenzo(g,h,i)perylen (0,01 – 200) mg/kg\nbenzo(a)fluoranten (0,01 – 1) mg/kg\ndibenzo(a,h)antracen (0,01 – 200) mg/kg\nbenzo(b)fluoranten (0,01 – 200) mg/kg\nbenzo(k)fluoranten 0,01 – 200) mg/kg\nindeno(1,2,3-c,d)piren (0,01 – 200) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"PN-ISO 13877:2004","norm_bases":["PN-ISO 13877:2004"],"lab_section":"Pracownia w Jaśle","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA)\nZakres:\nnaftalen (0,02 – 200) mg/kg\nfenantren (0,02 – 200) mg/kg\nantracen (0,01 – 200) mg/kg\nfluoranten (0,01 – 200) mg/kg\nchryzen (0,01 – 200) mg/kg\nbenzo(a)antracen (0,01 – 200) mg/kg\nbenzo(a)piren (0,01 – 200) mg/kg\nbenzo(g,h,i)perylen (0,01 – 200) mg/kg\nbenzo(a)fluoranten (0,01 – 1) mg/kg\ndibenzo(a,h)antracen (0,01 – 200) mg/kg\nbenzo(b)fluoranten (0,01 – 200) mg/kg\nbenzo(k)fluoranten 0,01 – 200) mg/kg\nindeno(1,2,3-c,d)piren (0,01 – 200) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) PN-ISO 13877:2004 Gleba Zawartosc wielopierscieniowych weglowodorow aromatycznych (WWA)\nZakres:\nnaftalen (0,02 – 200) mg/kg\nfenantren (0,02 – 200) mg/kg\nantracen (0,01 – 200) mg/kg\nfluoranten (0,01 – 200) mg/kg\nchryzen (0,01 – 200) mg/kg\nbenzo(a)antracen (0,01 – 200) mg/kg\nbenzo(a)piren (0,01 – 200) mg/kg\nbenzo(g,h,i)perylen (0,01 – 200) mg/kg\nbenzo(a)fluoranten (0,01 – 1) mg/kg\ndibenzo(a,h)antracen (0,01 – 200) mg/kg\nbenzo(b)fluoranten (0,01 – 200) mg/kg\nbenzo(k)fluoranten 0,01 – 200) mg/kg\nindeno(1,2,3-c,d)piren (0,01 – 200) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) PN-ISO 13877:2004","categories":["environment"],"row_index":94,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Polycyclic aromatic hydrocarbons (PAH) content","parameters_en":[{"name":"naphthalene","range":"(0,02 – 200) mg/kg"},{"name":"phenanthrene","range":"(0,02 – 200) mg/kg"},{"name":"anthracene","range":"(0,01 – 200) mg/kg"},{"name":"fluoranthene","range":"(0,01 – 200) mg/kg"},{"name":"chrysene","range":"(0,01 – 200) mg/kg"},{"name":"benzo(a)anthracene","range":"(0,01 – 200) mg/kg"},{"name":"benzo(a)pyrene","range":"(0,01 – 200) mg/kg"},{"name":"benzo(g,h,i)perylene","range":"(0,01 – 200) mg/kg"},{"name":"benzo(a)fluoranthene","range":"(0,01 – 1) mg/kg"},{"name":"dibenzo(a,h)anthracene","range":"(0,01 – 200) mg/kg"},{"name":"benzo(b)fluoranthene","range":"(0,01 – 200) mg/kg"},{"name":"benzo(k)fluoranthene","range":"0,01 – 200) mg/kg"},{"name":"indeno(1,2,3-c,d)pyrene","range":"(0,01 – 200) mg/kg"}],"search_en":"Soil Polycyclic aromatic hydrocarbons (PAH) content High-performance liquid chromatography with fluorescence detection (HPLC-FLD) naphthalene phenanthrene anthracene fluoranthene chrysene benzo(a)anthracene benzo(a)pyrene benzo(g,h,i)perylene benzo(a)fluoranthene dibenzo(a,h)anthracene benzo(b)fluoranthene benzo(k)fluoranthene indeno(1,2,3-c,d)pyrene PN-ISO 13877:2004","technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD)","test_object_en":"Soil","search_zh":"土壤 多环芳烃（PAHs）含量 高效液相色谱-荧光检测法（HPLC-FLD） 萘 菲 蒽 荧蒽 䓛 苯并（a）蒽 苯并（a）芘 苯并(g,h,i)苝 苯并(a)荧蒽 二苯并（a,h）蒽 苯并（b）荧蒽 苯并（k）荧蒽 茚并(1,2,3-c,d)芘 PN-ISO 13877:2004","technique_zh":"高效液相色谱-荧光检测法（HPLC-FLD）","test_object_zh":"土壤","parameters_zh":[{"name":"萘","range":"(0,02 – 200) mg/kg"},{"name":"菲","range":"(0,02 – 200) mg/kg"},{"name":"蒽","range":"(0,01 – 200) mg/kg"},{"name":"荧蒽","range":"(0,01 – 200) mg/kg"},{"name":"䓛","range":"(0,01 – 200) mg/kg"},{"name":"苯并（a）蒽","range":"(0,01 – 200) mg/kg"},{"name":"苯并（a）芘","range":"(0,01 – 200) mg/kg"},{"name":"苯并(g,h,i)苝","range":"(0,01 – 200) mg/kg"},{"name":"苯并(a)荧蒽","range":"(0,01 – 1) mg/kg"},{"name":"二苯并（a,h）蒽","range":"(0,01 – 200) mg/kg"},{"name":"苯并（b）荧蒽","range":"(0,01 – 200) mg/kg"},{"name":"苯并（k）荧蒽","range":"0,01 – 200) mg/kg"},{"name":"茚并(1,2,3-c,d)芘","range":"(0,01 – 200) mg/kg"}],"methodology_zh":"多环芳烃（PAHs）含量"},{"_id":"6a836e34af14b9c0e7b1e88f","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Gleba","methodology":"Suma wielopierścieniowych węglowodorów aromatycznych (WWA) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma wielopierścieniowych węglowodorów aromatycznych (WWA) (z obliczeń)","reference":"PN-ISO 13877:2004","norm_bases":["PN-ISO 13877:2004"],"lab_section":"Pracownia w Jaśle","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Suma wielopierścieniowych węglowodorów aromatycznych (WWA) (z obliczeń) PN-ISO 13877:2004 Gleba Suma wielopierscieniowych weglowodorow aromatycznych (WWA) (z obliczen) PN-ISO 13877:2004","categories":["environment"],"row_index":95,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of polycyclic aromatic hydrocarbons (PAH) (calculated)","search_en":"Soil Sum of polycyclic aromatic hydrocarbons (PAH) (calculated) PN-ISO 13877:2004","test_object_en":"Soil","search_zh":"土壤 多环芳烃（PAH）总量（由计算得出） PN-ISO 13877:2004","test_object_zh":"土壤","methodology_zh":"多环芳烃（PAH）总量（由计算得出）"},{"_id":"6a836e34af14b9c0e7b1e890","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Odpady O) kod: 01 04 09 10 01 01 10 09 03 10 12 03 10 11 05 17 01 02, 17 01 81 17 05 03, 17 05 04, 17 05 06 19 01 12 19 08 01 20 03 03","methodology":"Indeks fenolowy","parameters":[{"name":"Zakres","range":"(0,01 – 1) mg/l"},{"name":"Zakres","range":"(0,1 – 10) mg/kg"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Indeks fenolowy\nZakres:\nZakres (0,01 – 1) mg/l\nZakres (0,1 – 10) mg/kg\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 14402: 2004 pkt.4 | PN-EN 12457-2:2006 | PN-EN 12457-4:2006","norm_bases":["PN-EN ISO 14402: 2004 pkt.4","PN-EN 12457-2:2006","PN-EN 12457-4:2006"],"lab_section":"Pracownia w Jaśle","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015 poz. 1277). O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Odpady O) kod: 01 04 09 10 01 01 10 09 03 10 12 03 10 11 05 17 01 02, 17 01 81 17 05 03, 17 05 04, 17 05 06 19 01 12 19 08 01 20 03 03 Indeks fenolowy\nZakres:\nZakres (0,01 – 1) mg/l\nZakres (0,1 – 10) mg/kg\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 14402: 2004 pkt.4 | PN-EN 12457-2:2006 | PN-EN 12457-4:2006 Odpady O) kod: 01 04 09 10 01 01 10 09 03 10 12 03 10 11 05 17 01 02, 17 01 81 17 05 03, 17 05 04, 17 05 06 19 01 12 19 08 01 20 03 03 Indeks fenolowy\nZakres:\nZakres (0,01 – 1) mg/l\nZakres (0,1 – 10) mg/kg\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 14402: 2004 pkt.4 | PN-EN 12457-2:2006 | PN-EN 12457-4:2006","categories":["environment"],"row_index":96,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phenol index","parameters_en":[{"name":"Range","range":"(0,01 – 1) mg/l"},{"name":"Range","range":"(0,1 – 10) mg/kg"}],"search_en":"Phenol index Continuous flow analysis (CFA) with spectrophotometric detection Range Range PN-EN ISO 14402: 2004 pkt.4 | PN-EN 12457-2:2006 | PN-EN 12457-4:2006","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","parameters_zh":[{"name":"范围","range":"(0,01 – 1) mg/l"},{"name":"范围","range":"(0,1 – 10) mg/kg"}],"search_zh":"酚指数 连续流动分析（CFA）分光光度检测法 范围 范围 PN-EN ISO 14402: 2004 pkt.4 | PN-EN 12457-2:2006 | PN-EN 12457-4:2006","technique_zh":"连续流动分析（CFA）分光光度检测法","methodology_zh":"酚指数"},{"_id":"6a836e34af14b9c0e7b1e891","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Odpady O) kod: 10 01 01 17 01 07 19 12 12","methodology":"Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA)","parameters":[{"name":"naftalen","range":"(0,010 – 20) mg/kg"},{"name":"fenantren","range":"(0,010 – 20) mg/kg"},{"name":"antracen","range":"(0,010 – 20) mg/kg"},{"name":"fluoranten","range":"(0,010 – 20) mg/kg"},{"name":"chryzen","range":"(0,010 – 20) mg/kg"},{"name":"benzo(a)fluoranten","range":"(0,010 – 20) mg/kg"},{"name":"benzo(a)antracen","range":"(0,010 – 20) mg/kg"},{"name":"benzo(b)fluoranten","range":"(0,010 – 20) mg/kg"},{"name":"benzo(k)fluoranten","range":"(0,010 – 20) mg/kg"},{"name":"benzo(a)piren","range":"(0,010 – 20) mg/kg"},{"name":"dibenzo(a,h)antracen","range":"(0,010 – 20) mg/kg"},{"name":"benzo(g,h,i)perylen","range":"(0,010 – 20) mg/kg"},{"name":"indeno(123-cd)piren","range":"(0,010 – 20) mg/kg"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA)\nZakres:\nnaftalen (0,010 – 20) mg/kg\nfenantren (0,010 – 20) mg/kg\nantracen (0,010 – 20) mg/kg\nfluoranten (0,010 – 20) mg/kg\nchryzen (0,010 – 20) mg/kg\nbenzo(a)fluoranten (0,010 – 20) mg/kg\nbenzo(a)antracen (0,010 – 20) mg/kg\nbenzo(b)fluoranten (0,010 – 20) mg/kg\nbenzo(k)fluoranten (0,010 – 20) mg/kg\nbenzo(a)piren (0,010 – 20) mg/kg\ndibenzo(a,h)antracen (0,010 – 20) mg/kg\nbenzo(g,h,i)perylen (0,010 – 20) mg/kg\nindeno(123-cd)piren (0,010 – 20) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"PB-73/RZ wydanie 2 z dnia 01.03.2022 r.","norm_bases":["PB-73/RZ wydanie 2 z dnia 01.03.2022 r."],"lab_section":"Pracownia w Jaśle","lab_address":null,"regulatory_area":"O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Odpady O) kod: 10 01 01 17 01 07 19 12 12 Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA)\nZakres:\nnaftalen (0,010 – 20) mg/kg\nfenantren (0,010 – 20) mg/kg\nantracen (0,010 – 20) mg/kg\nfluoranten (0,010 – 20) mg/kg\nchryzen (0,010 – 20) mg/kg\nbenzo(a)fluoranten (0,010 – 20) mg/kg\nbenzo(a)antracen (0,010 – 20) mg/kg\nbenzo(b)fluoranten (0,010 – 20) mg/kg\nbenzo(k)fluoranten (0,010 – 20) mg/kg\nbenzo(a)piren (0,010 – 20) mg/kg\ndibenzo(a,h)antracen (0,010 – 20) mg/kg\nbenzo(g,h,i)perylen (0,010 – 20) mg/kg\nindeno(123-cd)piren (0,010 – 20) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) PB-73/RZ wydanie 2 z dnia 01.03.2022 r. Odpady O) kod: 10 01 01 17 01 07 19 12 12 Zawartosc wielopierscieniowych weglowodorow aromatycznych (WWA)\nZakres:\nnaftalen (0,010 – 20) mg/kg\nfenantren (0,010 – 20) mg/kg\nantracen (0,010 – 20) mg/kg\nfluoranten (0,010 – 20) mg/kg\nchryzen (0,010 – 20) mg/kg\nbenzo(a)fluoranten (0,010 – 20) mg/kg\nbenzo(a)antracen (0,010 – 20) mg/kg\nbenzo(b)fluoranten (0,010 – 20) mg/kg\nbenzo(k)fluoranten (0,010 – 20) mg/kg\nbenzo(a)piren (0,010 – 20) mg/kg\ndibenzo(a,h)antracen (0,010 – 20) mg/kg\nbenzo(g,h,i)perylen (0,010 – 20) mg/kg\nindeno(123-cd)piren (0,010 – 20) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) PB-73/RZ wydanie 2 z dnia 01.03.2022 r.","categories":["environment"],"row_index":97,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Polycyclic aromatic hydrocarbons (PAH) content","parameters_en":[{"name":"naphthalene","range":"(0,010 – 20) mg/kg"},{"name":"phenanthrene","range":"(0,010 – 20) mg/kg"},{"name":"anthracene","range":"(0,010 – 20) mg/kg"},{"name":"fluoranthene","range":"(0,010 – 20) mg/kg"},{"name":"chrysene","range":"(0,010 – 20) mg/kg"},{"name":"benzo(a)fluoranthene","range":"(0,010 – 20) mg/kg"},{"name":"benzo(a)anthracene","range":"(0,010 – 20) mg/kg"},{"name":"benzo(b)fluoranthene","range":"(0,010 – 20) mg/kg"},{"name":"benzo(k)fluoranthene","range":"(0,010 – 20) mg/kg"},{"name":"benzo(a)pyrene","range":"(0,010 – 20) mg/kg"},{"name":"dibenzo(a,h)anthracene","range":"(0,010 – 20) mg/kg"},{"name":"benzo(g,h,i)perylene","range":"(0,010 – 20) mg/kg"},{"name":"indeno(123-cd)pyrene","range":"(0,010 – 20) mg/kg"}],"search_en":"Polycyclic aromatic hydrocarbons (PAH) content High-performance liquid chromatography with fluorescence detection (HPLC-FLD) naphthalene phenanthrene anthracene fluoranthene chrysene benzo(a)fluoranthene benzo(a)anthracene benzo(b)fluoranthene benzo(k)fluoranthene benzo(a)pyrene dibenzo(a,h)anthracene benzo(g,h,i)perylene indeno(123-cd)pyrene PB-73/RZ wydanie 2 z dnia 01.03.2022 r.","technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD)","search_zh":"多环芳烃（PAHs）含量 高效液相色谱-荧光检测法（HPLC-FLD） 萘 菲 蒽 荧蒽 䓛 苯并(a)荧蒽 苯并（a）蒽 苯并（b）荧蒽 苯并（k）荧蒽 苯并（a）芘 二苯并（a,h）蒽 苯并(g,h,i)苝 PB-73/RZ wydanie 2 z dnia 01.03.2022 r.","technique_zh":"高效液相色谱-荧光检测法（HPLC-FLD）","parameters_zh":[{"name":"萘","range":"(0,010 – 20) mg/kg"},{"name":"菲","range":"(0,010 – 20) mg/kg"},{"name":"蒽","range":"(0,010 – 20) mg/kg"},{"name":"荧蒽","range":"(0,010 – 20) mg/kg"},{"name":"䓛","range":"(0,010 – 20) mg/kg"},{"name":"苯并(a)荧蒽","range":"(0,010 – 20) mg/kg"},{"name":"苯并（a）蒽","range":"(0,010 – 20) mg/kg"},{"name":"苯并（b）荧蒽","range":"(0,010 – 20) mg/kg"},{"name":"苯并（k）荧蒽","range":"(0,010 – 20) mg/kg"},{"name":"苯并（a）芘","range":"(0,010 – 20) mg/kg"},{"name":"二苯并（a,h）蒽","range":"(0,010 – 20) mg/kg"},{"name":"苯并(g,h,i)苝","range":"(0,010 – 20) mg/kg"},{"name":"indeno(123-cd)piren","range":"(0,010 – 20) mg/kg"}],"methodology_zh":"多环芳烃（PAHs）含量"},{"_id":"6a836e34af14b9c0e7b1e892","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Odpady O) kod: 10 01 01 17 01 07 19 12 12","methodology":"Suma wielopierścieniowych węglowodorów aromatycznych (WWA) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma wielopierścieniowych węglowodorów aromatycznych (WWA) (z obliczeń)","reference":"PB-73/RZ wydanie 2 z dnia 01.03.2022 r.","norm_bases":["PB-73/RZ wydanie 2 z dnia 01.03.2022 r."],"lab_section":"Pracownia w Jaśle","lab_address":null,"regulatory_area":"O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Odpady O) kod: 10 01 01 17 01 07 19 12 12 Suma wielopierścieniowych węglowodorów aromatycznych (WWA) (z obliczeń) PB-73/RZ wydanie 2 z dnia 01.03.2022 r. Odpady O) kod: 10 01 01 17 01 07 19 12 12 Suma wielopierscieniowych weglowodorow aromatycznych (WWA) (z obliczen) PB-73/RZ wydanie 2 z dnia 01.03.2022 r.","categories":["environment"],"row_index":98,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of polycyclic aromatic hydrocarbons (PAH) (calculated)","search_en":"Sum of polycyclic aromatic hydrocarbons (PAH) (calculated) PB-73/RZ wydanie 2 z dnia 01.03.2022 r.","methodology_zh":"多环芳烃（PAH）总量（由计算得出）","search_zh":"多环芳烃（PAH）总量（由计算得出） PB-73/RZ wydanie 2 z dnia 01.03.2022 r."},{"_id":"6a836e34af14b9c0e7b1e893","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda","methodology":"Indeks nadmanganianowy","parameters":[{"name":"Zakres","range":"(0,80 – 100) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Indeks nadmanganianowy\nZakres (0,80 – 100) mg/l O2\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":"Pracownia w Przemyślu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Indeks nadmanganianowy\nZakres (0,80 – 100) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda Indeks nadmanganianowy\nZakres (0,80 – 100) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":99,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Permanganate index","parameters_en":[{"name":"Range","range":"(0,80 – 100) mg/l O2"}],"search_en":"Water Permanganate index Titrimetric method Range PN-EN ISO 8467:2001","technique_en":"Titrimetric method","test_object_en":"Water","methodology_zh":"高锰酸盐指数","parameters_zh":[{"name":"范围","range":"(0,80 – 100) mg/l O2"}],"search_zh":"水 高锰酸盐指数 滴定法 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"水"},{"_id":"6a836e34af14b9c0e7b1e894","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)","parameters":[{"name":"Zakres","range":"(10,0 – 2000) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (10,0 – 2000) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":"Pracownia w Przemyślu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (10,0 – 2000) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999 Woda Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna)\nZakres (10,0 – 2000) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":100,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total content of calcium and magnesium (total hardness)","parameters_en":[{"name":"Range","range":"(10,0 – 2000) mg/l CaCO3"}],"search_en":"Water Total content of calcium and magnesium (total hardness) Titrimetric method Range PN-ISO 6059:1999","technique_en":"Titrimetric method","test_object_en":"Water","methodology_zh":"钙与镁总量（总硬度）","parameters_zh":[{"name":"范围","range":"(10,0 – 2000) mg/l CaCO3"}],"search_zh":"水 钙与镁总量（总硬度） 滴定法 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"水"},{"_id":"6a836e34af14b9c0e7b1e895","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie anionów","parameters":[{"name":"Fluorki","range":"(0,10 – 100) mg/l"},{"name":"Chlorki","range":"(0,50 – 5 000) mg/l"},{"name":"Azotany","range":"(0,10 – 500) mg/l"},{"name":"Siarczany","range":"(0,50 – 1000) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie anionów\nZakres:\nFluorki (0,10 – 100) mg/l\nChlorki (0,50 – 5 000) mg/l\nAzotany (0,10 – 500) mg/l\nSiarczany (0,50 – 1000) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009 +AC:2012","norm_bases":["PN-EN ISO 10304-1:2009 +AC:2012"],"lab_section":"Pracownia w Przemyślu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie anionów\nZakres:\nFluorki (0,10 – 100) mg/l\nChlorki (0,50 – 5 000) mg/l\nAzotany (0,10 – 500) mg/l\nSiarczany (0,50 – 1000) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009 +AC:2012 Woda Stezenie anionow\nZakres:\nFluorki (0,10 – 100) mg/l\nChlorki (0,50 – 5 000) mg/l\nAzotany (0,10 – 500) mg/l\nSiarczany (0,50 – 1000) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009 +AC:2012","categories":["water"],"row_index":101,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Anion concentrations","parameters_en":[{"name":"Fluorides","range":"(0,10 – 100) mg/l"},{"name":"Chlorides","range":"(0,50 – 5 000) mg/l"},{"name":"Nitrates","range":"(0,10 – 500) mg/l"},{"name":"Sulfates","range":"(0,50 – 1000) mg/l"}],"search_en":"Water Anion concentrations Ion chromatography with conductometric detection (IC-CD) Fluorides Chlorides Nitrates Sulfates PN-EN ISO 10304-1:2009 +AC:2012","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water","methodology_zh":"阴离子浓度","parameters_zh":[{"name":"氟化物","range":"(0,10 – 100) mg/l"},{"name":"氯化物","range":"(0,50 – 5 000) mg/l"},{"name":"硝酸盐","range":"(0,10 – 500) mg/l"},{"name":"硫酸盐","range":"(0,50 – 1000) mg/l"}],"search_zh":"水 阴离子浓度 离子色谱-电导检测法（IC-CD） 氟化物 氯化物 硝酸盐 硫酸盐 PN-EN ISO 10304-1:2009 +AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水"},{"_id":"6a836e34af14b9c0e7b1e896","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5, BZT 2+5","parameters":[{"name":"Zakres","range":"(0,5 – 6,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5, BZT 2+5\nZakres (0,5 – 6,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":"Pracownia w Przemyślu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu - BZT5, BZT 2+5\nZakres (0,5 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Woda, scieki Biochemiczne zapotrzebowanie tlenu - BZT5, BZT 2+5\nZakres (0,5 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":102,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,5 – 6,0) mg/l O2"}],"search_en":"Water, wastewater Electrochemical method Range PN-EN 1899-2:2002","technique_en":"Electrochemical method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,5 – 6,0) mg/l O2"}],"search_zh":"水、废水 电化学法 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"水、废水"},{"_id":"6a836e34af14b9c0e7b1e897","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5, BZT 2+5","parameters":[{"name":"Zakres","range":"(3 – 6000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5, BZT 2+5\nZakres (3 – 6000) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Pracownia w Przemyślu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu - BZT5, BZT 2+5\nZakres (3 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Woda, scieki Biochemiczne zapotrzebowanie tlenu - BZT5, BZT 2+5\nZakres (3 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":103,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(3 – 6000) mg/l O2"}],"search_en":"Water, wastewater Electrochemical method Range PN-EN ISO 5815-1:2019-12","technique_en":"Electrochemical method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(3 – 6000) mg/l O2"}],"search_zh":"水、废水 电化学法 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"水、废水"},{"_id":"6a836e34af14b9c0e7b1e898","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0 – 2000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 2000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Pracownia w Przemyślu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Zawiesiny ogólne\nZakres (2,0 – 2000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, scieki Zawiesiny ogolne\nZakres (2,0 – 2000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":104,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2,0 – 2000) mg/l"}],"search_en":"Water, wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 2000) mg/l"}],"search_zh":"水、废水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"水、废水"},{"_id":"6a836e34af14b9c0e7b1e899","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Całkowite substancje rozpuszczone (TDS)","parameters":[{"name":"Zakres","range":"(50,0 – 2000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Całkowite substancje rozpuszczone (TDS)\nZakres (50,0 – 2000) mg/l\nMetoda wagowa","reference":"PN-EN 15216:2022-03","norm_bases":["PN-EN 15216:2022-03"],"lab_section":"Pracownia w Przemyślu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Całkowite substancje rozpuszczone (TDS)\nZakres (50,0 – 2000) mg/l\nMetoda wagowa PN-EN 15216:2022-03 Woda, scieki Calkowite substancje rozpuszczone (TDS)\nZakres (50,0 – 2000) mg/l\nMetoda wagowa PN-EN 15216:2022-03","categories":["water"],"row_index":105,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total dissolved solids (TDS)","parameters_en":[{"name":"Range","range":"(50,0 – 2000) mg/l"}],"search_en":"Water, wastewater Total dissolved solids (TDS) Gravimetric method Range PN-EN 15216:2022-03","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(50,0 – 2000) mg/l"}],"search_zh":"水、废水 溶解性总固体（TDS） 重量法 范围 PN-EN 15216:2022-03","technique_zh":"重量法","test_object_zh":"水、废水","methodology_zh":"溶解性总固体（TDS）"},{"_id":"6a836e34af14b9c0e7b1e89a","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(3,00 – 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (3,00 – 1000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":"Pracownia w Przemyślu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu amonowego\nZakres (3,00 – 1000) mg/l\nMetoda miareczkowa PN-ISO 5664:2002 Woda, scieki Stezenie azotu amonowego\nZakres (3,00 – 1000) mg/l\nMetoda miareczkowa PN-ISO 5664:2002","categories":["water"],"row_index":106,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(3,00 – 1000) mg/l"}],"search_en":"Water, wastewater Ammonium nitrogen concentration Titrimetric method Range PN-ISO 5664:2002","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(3,00 – 1000) mg/l"}],"search_zh":"水、废水 氨氮浓度 滴定法 范围 PN-ISO 5664:2002","technique_zh":"滴定法","test_object_zh":"水、废水"},{"_id":"6a836e34af14b9c0e7b1e89b","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,050 – 20,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,050 – 20,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Pracownia w Przemyślu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu amonowego\nZakres (0,050 – 20,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, scieki Stezenie azotu amonowego\nZakres (0,050 – 20,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":107,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,050 – 20,0) mg/l"}],"search_en":"Water, wastewater Ammonium nitrogen concentration Spectrophotometric method Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,050 – 20,0) mg/l"}],"search_zh":"水、废水 氨氮浓度 分光光度法 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a836e34af14b9c0e7b1e89c","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,0020 – 10,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres (0,0020 – 10,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Pracownia w Przemyślu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu azotynowego\nZakres (0,0020 – 10,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, scieki Stezenie azotu azotynowego\nZakres (0,0020 – 10,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":108,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,0020 – 10,0) mg/l"}],"search_en":"Water, wastewater Nitrite nitrogen concentration Spectrophotometric method Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,0020 – 10,0) mg/l"}],"search_zh":"水、废水 亚硝态氮浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a836e34af14b9c0e7b1e89d","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu ogólnego Suma NKjeld, NNO2 i NNO3 (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu ogólnego Suma NKjeld, NNO2 i NNO3 (z obliczeń)","reference":"PB-26/CLB Wydanie 1 z dnia 16.01.2026","norm_bases":["PB-26/CLB Wydanie 1 z dnia 16.01.2026"],"lab_section":"Pracownia w Przemyślu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu ogólnego Suma NKjeld, NNO2 i NNO3 (z obliczeń) PB-26/CLB Wydanie 1 z dnia 16.01.2026 Woda, scieki Stezenie azotu ogolnego Suma NKjeld, NNO2 i NNO3 (z obliczen) PB-26/CLB Wydanie 1 z dnia 16.01.2026","categories":["water"],"row_index":109,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Water, wastewater PB-26/CLB Wydanie 1 z dnia 16.01.2026","test_object_en":"Water, wastewater","search_zh":"水、废水 PB-26/CLB Wydanie 1 z dnia 16.01.2026","test_object_zh":"水、废水"},{"_id":"6a836e34af14b9c0e7b1e89e","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie fosforanów rozpuszczonych","parameters":[{"name":"Zakres","range":"(0,030 – 307) mg/l"},{"name":"Zakres","range":"(0,010 – 100) mg/l P"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforanów rozpuszczonych\nZakres:\nZakres (0,030 – 307) mg/l\nZakres (0,010 – 100) mg/l P\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 pkt 4 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 pkt 4 +Ap1:2010+Ap2:2010"],"lab_section":"Pracownia w Przemyślu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie fosforanów rozpuszczonych\nZakres:\nZakres (0,030 – 307) mg/l\nZakres (0,010 – 100) mg/l P\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt 4 +Ap1:2010+Ap2:2010 Woda, scieki Stezenie fosforanow rozpuszczonych\nZakres:\nZakres (0,030 – 307) mg/l\nZakres (0,010 – 100) mg/l P\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt 4 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":110,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissolved phosphate concentration","parameters_en":[{"name":"Range","range":"(0,030 – 307) mg/l"},{"name":"Range","range":"(0,010 – 100) mg/l P"}],"search_en":"Water, wastewater Dissolved phosphate concentration Spectrophotometric method Range Range PN-EN ISO 6878:2006 pkt 4 +Ap1:2010+Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,030 – 307) mg/l"},{"name":"范围","range":"(0,010 – 100) mg/l P"}],"search_zh":"水、废水 溶解性磷酸盐浓度 分光光度法 范围 范围 PN-EN ISO 6878:2006 pkt 4 +Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"溶解性磷酸盐浓度"},{"_id":"6a836e34af14b9c0e7b1e89f","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,025 – 100) mg/l P"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,025 – 100) mg/l P\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 pkt 8 +Ap1:2010 +Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 pkt 8 +Ap1:2010 +Ap2:2010"],"lab_section":"Pracownia w Przemyślu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie fosforu ogólnego\nZakres (0,025 – 100) mg/l P\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt 8 +Ap1:2010 +Ap2:2010 Woda, scieki Stezenie fosforu ogolnego\nZakres (0,025 – 100) mg/l P\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt 8 +Ap1:2010 +Ap2:2010","categories":["water"],"row_index":111,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,025 – 100) mg/l P"}],"search_en":"Water, wastewater Total phosphorus concentration Spectrophotometric method Range PN-EN ISO 6878:2006 pkt 8 +Ap1:2010 +Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,025 – 100) mg/l P"}],"search_zh":"水、废水 总磷浓度 分光光度法 范围 PN-EN ISO 6878:2006 pkt 8 +Ap1:2010 +Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a836e34af14b9c0e7b1e8a0","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr","parameters":[{"name":"Zakres","range":"(5,0 – 5 000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (5,0 – 5 000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN ISO 15705:2005","norm_bases":["PN ISO 15705:2005"],"lab_section":"Pracownia w Przemyślu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (5,0 – 5 000) mg/l O2\nMetoda spektrofotometryczna PN ISO 15705:2005 Woda, scieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (5,0 – 5 000) mg/l O2\nMetoda spektrofotometryczna PN ISO 15705:2005","categories":["water"],"row_index":112,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand - COD-Cr","parameters_en":[{"name":"Range","range":"(5,0 – 5 000) mg/l O2"}],"search_en":"Water, wastewater Chemical oxygen demand - COD-Cr Spectrophotometric method Range PN ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(5,0 – 5 000) mg/l O2"}],"search_zh":"水、废水 化学需氧量（COD-Cr） 分光光度法 范围 PN ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"化学需氧量（COD-Cr）"},{"_id":"6a836e34af14b9c0e7b1e8a1","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Zasadowość ogólna","parameters":[{"name":"Zakres","range":"(10,0 – 2000) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zasadowość ogólna\nZakres (10,0 – 2000) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-EN ISO 9963-1:2001 pkt 8.2 + Ap1:2004","norm_bases":["PN-EN ISO 9963-1:2001 pkt 8.2 + Ap1:2004"],"lab_section":"Pracownia w Przemyślu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Zasadowość ogólna\nZakres (10,0 – 2000) mg/l CaCO3\nMetoda miareczkowa PN-EN ISO 9963-1:2001 pkt 8.2 + Ap1:2004 Woda, scieki Zasadowosc ogolna\nZakres (10,0 – 2000) mg/l CaCO3\nMetoda miareczkowa PN-EN ISO 9963-1:2001 pkt 8.2 + Ap1:2004","categories":["water"],"row_index":113,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total alkalinity","parameters_en":[{"name":"Range","range":"(10,0 – 2000) mg/l CaCO3"}],"search_en":"Water, wastewater Total alkalinity Titrimetric method Range PN-EN ISO 9963-1:2001 pkt 8.2 + Ap1:2004","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(10,0 – 2000) mg/l CaCO3"}],"search_zh":"水、废水 总碱度 滴定法 范围 PN-EN ISO 9963-1:2001 pkt 8.2 + Ap1:2004","technique_zh":"滴定法","test_object_zh":"水、废水","methodology_zh":"总碱度"},{"_id":"6a836e34af14b9c0e7b1e8a2","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie chromu (VI)","parameters":[{"name":"Zakres","range":"(0,010 – 10,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chromu (VI)\nZakres (0,010 – 10,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-77/C-04604/08","norm_bases":["PN-77/C-04604/08"],"lab_section":"Pracownia w Przemyślu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie chromu (VI)\nZakres (0,010 – 10,0) mg/l\nMetoda spektrofotometryczna PN-77/C-04604/08 Scieki Stezenie chromu (VI)\nZakres (0,010 – 10,0) mg/l\nMetoda spektrofotometryczna PN-77/C-04604/08","categories":["water"],"row_index":114,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chromium(VI) concentration","parameters_en":[{"name":"Range","range":"(0,010 – 10,0) mg/l"}],"search_en":"Wastewater Chromium(VI) concentration Spectrophotometric method Range PN-77/C-04604/08","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(0,010 – 10,0) mg/l"}],"search_zh":"污水 六价铬浓度 分光光度法 范围 PN-77/C-04604/08","technique_zh":"分光光度法","test_object_zh":"污水","methodology_zh":"六价铬浓度"},{"_id":"6a836e34af14b9c0e7b1e8a3","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie chromu (III) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie chromu (III) (z obliczeń)","reference":"PN-77/C-04604/08","norm_bases":["PN-77/C-04604/08"],"lab_section":"Pracownia w Przemyślu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie chromu (III) (z obliczeń) PN-77/C-04604/08 Scieki Stezenie chromu (III) (z obliczen) PN-77/C-04604/08","categories":["water"],"row_index":115,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chromium (III) concentration (calculated)","search_en":"Wastewater Chromium (III) concentration (calculated) PN-77/C-04604/08","test_object_en":"Wastewater","search_zh":"污水 铬(III)浓度（由计算得出） PN-77/C-04604/08","test_object_zh":"污水","methodology_zh":"铬(III)浓度（由计算得出）"},{"_id":"6a836e34af14b9c0e7b1e8a4","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie chromu","parameters":[{"name":"Zakres","range":"(0,010 – 10,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chromu\nZakres (0,010 – 10,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-77/C-04604/02","norm_bases":["PN-77/C-04604/02"],"lab_section":"Pracownia w Przemyślu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie chromu\nZakres (0,010 – 10,0) mg/l\nMetoda spektrofotometryczna PN-77/C-04604/02 Scieki Stezenie chromu\nZakres (0,010 – 10,0) mg/l\nMetoda spektrofotometryczna PN-77/C-04604/02","categories":["water"],"row_index":116,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chromium concentration","parameters_en":[{"name":"Range","range":"(0,010 – 10,0) mg/l"}],"search_en":"Wastewater Chromium concentration Spectrophotometric method Range PN-77/C-04604/02","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(0,010 – 10,0) mg/l"}],"search_zh":"污水 铬浓度 分光光度法 范围 PN-77/C-04604/02","technique_zh":"分光光度法","test_object_zh":"污水","methodology_zh":"铬浓度"},{"_id":"6a836e34af14b9c0e7b1e8a5","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie anionów","parameters":[{"name":"Chlorki","range":"(0,50 – 5 000) mg/l"},{"name":"Azotany","range":"(0,10 – 500) mg/l"},{"name":"Siarczany","range":"(0,50 – 1 000) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie anionów\nZakres:\nChlorki (0,50 – 5 000) mg/l\nAzotany (0,10 – 500) mg/l\nSiarczany (0,50 – 1 000) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009 +AC:2012","norm_bases":["PN-EN ISO 10304-1:2009 +AC:2012"],"lab_section":"Pracownia w Przemyślu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie anionów\nZakres:\nChlorki (0,50 – 5 000) mg/l\nAzotany (0,10 – 500) mg/l\nSiarczany (0,50 – 1 000) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009 +AC:2012 Scieki Stezenie anionow\nZakres:\nChlorki (0,50 – 5 000) mg/l\nAzotany (0,10 – 500) mg/l\nSiarczany (0,50 – 1 000) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009 +AC:2012","categories":["water"],"row_index":117,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Anion concentrations","parameters_en":[{"name":"Chlorides","range":"(0,50 – 5 000) mg/l"},{"name":"Nitrates","range":"(0,10 – 500) mg/l"},{"name":"Sulfates","range":"(0,50 – 1 000) mg/l"}],"search_en":"Wastewater Anion concentrations Ion chromatography with conductometric detection (IC-CD) Chlorides Nitrates Sulfates PN-EN ISO 10304-1:2009 +AC:2012","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Wastewater","methodology_zh":"阴离子浓度","parameters_zh":[{"name":"氯化物","range":"(0,50 – 5 000) mg/l"},{"name":"硝酸盐","range":"(0,10 – 500) mg/l"},{"name":"硫酸盐","range":"(0,50 – 1 000) mg/l"}],"search_zh":"污水 阴离子浓度 离子色谱-电导检测法（IC-CD） 氯化物 硝酸盐 硫酸盐 PN-EN ISO 10304-1:2009 +AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"污水"},{"_id":"6a836e34af14b9c0e7b1e8a6","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(5,0 – 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (5,0 – 1000) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":"Pracownia w Przemyślu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu Kjeldahla\nZakres (5,0 – 1000) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Woda, scieki Stezenie azotu Kjeldahla\nZakres (5,0 – 1000) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":118,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(5,0 – 1000) mg/l"}],"search_en":"Water, wastewater Kjeldahl nitrogen concentration Titrimetric method Range PN-EN 25663:2001","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(5,0 – 1000) mg/l"}],"search_zh":"水、废水 凯氏氮浓度 滴定法 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"水、废水"},{"_id":"6a836e34af14b9c0e7b1e8a7","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(0,30 – 20,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (0,30 – 20,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 25663:2001 | PN-ISO 7150-1:2002","norm_bases":["PN-EN 25663:2001","PN-ISO 7150-1:2002"],"lab_section":"Pracownia w Przemyślu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu Kjeldahla\nZakres (0,30 – 20,0) mg/l\nMetoda spektrofotometryczna PN-EN 25663:2001 | PN-ISO 7150-1:2002 Woda, scieki Stezenie azotu Kjeldahla\nZakres (0,30 – 20,0) mg/l\nMetoda spektrofotometryczna PN-EN 25663:2001 | PN-ISO 7150-1:2002","categories":["water"],"row_index":119,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,30 – 20,0) mg/l"}],"search_en":"Water, wastewater Kjeldahl nitrogen concentration Spectrophotometric method Range PN-EN 25663:2001 | PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(0,30 – 20,0) mg/l"}],"search_zh":"水、废水 凯氏氮浓度 分光光度法 范围 PN-EN 25663:2001 | PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a836e34af14b9c0e7b1e8a8","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie rtęci","parameters":[{"name":"Zakres","range":"(0,00050 – 2,00) mg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","techniques":["Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji"],"computed":[],"activity":"Stężenie rtęci\nZakres (0,00050 – 2,00) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","reference":"PB-99/RZ wydanie 1 z dnia 15.05.2024 r.","norm_bases":["PB-99/RZ wydanie 1 z dnia 15.05.2024 r."],"lab_section":"Pracownia w Przemyślu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie rtęci\nZakres (0,00050 – 2,00) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji PB-99/RZ wydanie 1 z dnia 15.05.2024 r. Woda, scieki Stezenie rteci\nZakres (0,00050 – 2,00) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z technika amalgamacji PB-99/RZ wydanie 1 z dnia 15.05.2024 r.","categories":["water"],"row_index":120,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury concentration","parameters_en":[{"name":"Range","range":"(0,00050 – 2,00) mg/l"}],"search_en":"Water, wastewater Mercury concentration Atomic absorption spectrometry with amalgamation technique Range PB-99/RZ wydanie 1 z dnia 15.05.2024 r.","technique_en":"Atomic absorption spectrometry with amalgamation technique","test_object_en":"Water, wastewater","methodology_zh":"汞浓度","parameters_zh":[{"name":"范围","range":"(0,00050 – 2,00) mg/l"}],"search_zh":"水、废水 汞浓度 原子吸收光谱法（汞齐化技术） 范围 PB-99/RZ wydanie 1 z dnia 15.05.2024 r.","technique_zh":"原子吸收光谱法（汞齐化技术）","test_object_zh":"水、废水"},{"_id":"6a836e34af14b9c0e7b1e8a9","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"Zawartość rtęci","parameters":[{"name":"Zakres","range":"(0,0030 – 5,00) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","techniques":["Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji"],"computed":[],"activity":"Zawartość rtęci\nZakres (0,0030 – 5,00) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","reference":"PB-99/RZ wydanie 1 z dnia 15.05.2024 r.","norm_bases":["PB-99/RZ wydanie 1 z dnia 15.05.2024 r."],"lab_section":"Pracownia w Przemyślu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty Zawartość rtęci\nZakres (0,0030 – 5,00) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji PB-99/RZ wydanie 1 z dnia 15.05.2024 r. Gleba, grunty Zawartosc rteci\nZakres (0,0030 – 5,00) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z technika amalgamacji PB-99/RZ wydanie 1 z dnia 15.05.2024 r.","categories":["environment"],"row_index":121,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury content","parameters_en":[{"name":"Range","range":"(0,0030 – 5,00) mg/kg"}],"search_en":"Soil, ground Mercury content Atomic absorption spectrometry with amalgamation technique Range PB-99/RZ wydanie 1 z dnia 15.05.2024 r.","technique_en":"Atomic absorption spectrometry with amalgamation technique","test_object_en":"Soil, ground","methodology_zh":"汞含量","parameters_zh":[{"name":"范围","range":"(0,0030 – 5,00) mg/kg"}],"search_zh":"土壤、土体 汞含量 原子吸收光谱法（汞齐化技术） 范围 PB-99/RZ wydanie 1 z dnia 15.05.2024 r.","technique_zh":"原子吸收光谱法（汞齐化技术）","test_object_zh":"土壤、土体"},{"_id":"6a836e34af14b9c0e7b1e8aa","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"OdpadyO) kod: 10 04 01 17 01 02, 17 01 81, 17 05 06 20 03 03","methodology":"Stężenie i zawartość rtęci","parameters":[{"name":"Zakres","range":"(0,00050 – 2,00) mg/l"},{"name":"Zakres","range":"(0,0050 – 20,0) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","techniques":["Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji"],"computed":[],"activity":"Stężenie i zawartość rtęci\nZakres:\nZakres (0,00050 – 2,00) mg/l\nZakres (0,0050 – 20,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","reference":"PB-99/RZ wydanie 1 z dnia 15.05.2024 r. | PN-EN 12457-2:2006 | PN-EN 12457-4:2006","norm_bases":["PB-99/RZ wydanie 1 z dnia 15.05.2024 r.","PN-EN 12457-2:2006","PN-EN 12457-4:2006"],"lab_section":"Pracownia w Przemyślu","lab_address":null,"regulatory_area":"O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"OdpadyO) kod: 10 04 01 17 01 02, 17 01 81, 17 05 06 20 03 03 Stężenie i zawartość rtęci\nZakres:\nZakres (0,00050 – 2,00) mg/l\nZakres (0,0050 – 20,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji PB-99/RZ wydanie 1 z dnia 15.05.2024 r. | PN-EN 12457-2:2006 | PN-EN 12457-4:2006 OdpadyO) kod: 10 04 01 17 01 02, 17 01 81, 17 05 06 20 03 03 Stezenie i zawartosc rteci\nZakres:\nZakres (0,00050 – 2,00) mg/l\nZakres (0,0050 – 20,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z technika amalgamacji PB-99/RZ wydanie 1 z dnia 15.05.2024 r. | PN-EN 12457-2:2006 | PN-EN 12457-4:2006","categories":["environment"],"row_index":122,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury concentration and content","parameters_en":[{"name":"Range","range":"(0,00050 – 2,00) mg/l"},{"name":"Range","range":"(0,0050 – 20,0) mg/kg"}],"search_en":"Mercury concentration and content Atomic absorption spectrometry with amalgamation technique Range Range PB-99/RZ wydanie 1 z dnia 15.05.2024 r. | PN-EN 12457-2:2006 | PN-EN 12457-4:2006","technique_en":"Atomic absorption spectrometry with amalgamation technique","parameters_zh":[{"name":"范围","range":"(0,00050 – 2,00) mg/l"},{"name":"范围","range":"(0,0050 – 20,0) mg/kg"}],"search_zh":"汞的浓度与含量 原子吸收光谱法（汞齐化技术） 范围 范围 PB-99/RZ wydanie 1 z dnia 15.05.2024 r. | PN-EN 12457-2:2006 | PN-EN 12457-4:2006","technique_zh":"原子吸收光谱法（汞齐化技术）","methodology_zh":"汞的浓度与含量"},{"_id":"6a836e34af14b9c0e7b1e8ab","lab_id":"69ad52a3de79e566650fb23b","country":"PL","accr_number":"AB 447","accr_body":"PCA","test_object":"Osady ściekowe OdpadyO) kod: 17 05 03, 17 05 04, 17 05 05, 17 05 06 19 08 05","methodology":"Zawartość rtęci","parameters":[{"name":"Zakres","range":"(0,0030 – 5,00) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","techniques":["Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji"],"computed":[],"activity":"Zawartość rtęci\nZakres (0,0030 – 5,00) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","reference":"PB-99/RZ wydanie 1 z dnia 15.05.2024 r.","norm_bases":["PB-99/RZ wydanie 1 z dnia 15.05.2024 r."],"lab_section":"Pracownia w Przemyślu","lab_address":null,"regulatory_area":"O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Osady ściekowe OdpadyO) kod: 17 05 03, 17 05 04, 17 05 05, 17 05 06 19 08 05 Zawartość rtęci\nZakres (0,0030 – 5,00) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji PB-99/RZ wydanie 1 z dnia 15.05.2024 r. Osady sciekowe OdpadyO) kod: 17 05 03, 17 05 04, 17 05 05, 17 05 06 19 08 05 Zawartosc rteci\nZakres (0,0030 – 5,00) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z technika amalgamacji PB-99/RZ wydanie 1 z dnia 15.05.2024 r.","categories":["water","environment"],"row_index":123,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury content","parameters_en":[{"name":"Range","range":"(0,0030 – 5,00) mg/kg"}],"search_en":"Mercury content Atomic absorption spectrometry with amalgamation technique Range PB-99/RZ wydanie 1 z dnia 15.05.2024 r.","technique_en":"Atomic absorption spectrometry with amalgamation technique","methodology_zh":"汞含量","parameters_zh":[{"name":"范围","range":"(0,0030 – 5,00) mg/kg"}],"search_zh":"汞含量 原子吸收光谱法（汞齐化技术） 范围 PB-99/RZ wydanie 1 z dnia 15.05.2024 r.","technique_zh":"原子吸收光谱法（汞齐化技术）"}],"has_pdf":true}