{"lab":{"_id":"69ad52a3de79e566650fb239","accr_number":"AB 444","country":"PL","accr_body":"PCA","address":"ul. Żyrzyńska 42, 24-130 Końskowola","categories":["food","microbiology","water","environment","petro"],"city":"Końskowola","imported_at":"2026-03-08T10:42:43.265Z","methods_count":114,"name":"AGROLAB POLSKA Sp. z o.o.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_444.pdf"],"scope_summary":"","search_text":"agrolab polska sp. z o.o. ul. żyrzyńska 42, 24-130 końskowola other food pharma electronics metrology water petro microbiology automotive environment materials","status":"active","updated_at":"2026-03-08T14:51:17.315Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-17T20:17:28.684Z","email_confidence":"high","email_mx":true,"email_source":"https://www.pca.gov.pl/akredytowane-podmioty/akredytacje-aktywne/laboratoria-badawcze/AB%20444,podmiot.html","fields_of_testing":[{"codes":"C/1; C/22, C/29, C/55","pl":"Badania chemiczne produktów rolnych, żywności, wody do spożycia przez ludzi, pasz dla zwierząt","en":"Chemical tests of agricultural products, food; drinking water, animal foodsruffs"},{"codes":"K/4; K/22, K/28, K/29, K/55, K/57","pl":"Badania mikrobiologiczne, kosmetyków, żywności, wody, wody do spożycia przez ludzi, pasz dla zwierząt, obiektów z obszaru produkcji żywności","en":"Microbiological tests of cosmetics, food, water, drinking water, animal feedstuffs, objects from food production area;"},{"codes":"B/1; B/22","pl":"Badania biologiczne i biochemiczne produktów rolnych, żywności","en":"Biological and biochemical tests of agricultural products, food"},{"codes":"N/22, N/29, N/55","pl":"Badania właściwości fizycznych żywności, wody do spożycia przez ludzi, pasz dla zwierząt","en":"Tests of physical properties of food; drinking water, animal feedstuffs"},{"codes":"Q/22; Q/55","pl":"Badania sensoryczne żywności, pasz","en":"Sensory tests of food, feed."},{"codes":"P/29, P/57","pl":"Pobieranie próbek wody do spożycia przez ludzi, obiektów z obszaru produkcji żywności","en":"Sampling of drinking water, objects from food production area."}],"issue":{"no":"27","date":"23.06.2026"},"parse_date":"2026-08-17T20:17:28.684Z","parse_source":"agent-claude-code","map_coord":[51.419579,22.060088],"map_geo":"nominatim-street","lab_locations":[{"name":"Pracownia Analiz Fizyko-chemicznych","address":"ul. Żyrzyńska 42, 24-130 Końskowola","city":"Końskowola","postal":"24-130"},{"name":"Pracownia Analiz Instrumentalnych","address":"ul. Żyrzyńska 42, 24-130 Końskowola","city":"Końskowola","postal":"24-130"},{"name":"Pracownia Mikrobiologiczna","address":"ul. Żyrzyńska 42, 24-130 Końskowola","city":"Końskowola","postal":"24-130"}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/bbe81edcb98b91addd6dd97ee9acffe0/AB%20444.pdf","has_en":true,"category_counts":{"food":72,"other":26,"microbiology":22,"water":14,"environment":8,"petro":7,"materials":4,"pharma":3},"category_scores":{"food":33.23,"other":4.33,"microbiology":3.1,"water":1.26,"environment":0.41,"petro":0.31,"materials":0.1,"pharma":0.06},"has_zh":true,"lab_locations_zh":[{"name":"Pracownia Analiz Fizyko-chemicznych","address":"ul. Żyrzyńska 42, 24-130 Końskowola","city":"Końskowola","postal":"24-130"},{"name":"仪器分析检验室","address":"ul. Żyrzyńska 42, 24-130 Końskowola","city":"Końskowola","postal":"24-130"},{"name":"Pracownia Mikrobiologiczna","address":"ul. Żyrzyńska 42, 24-130 Końskowola","city":"Końskowola","postal":"24-130"}]},"methods":[{"_id":"6a836c58af14b9c0e7b1e35a","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Koncentraty spożywcze","methodology":"Zawartość cukrów ogółem i cukrów redukujących","parameters":[{"name":"Zakres cukry ogółem","range":"(5,5 - 85,0)%"},{"name":"Zakres cukry redukujące","range":"(2,5 - 50,0)%"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość cukrów ogółem i cukrów redukujących\nZakres:\nZakres cukry ogółem (5,5 - 85,0)%\nZakres cukry redukujące (2,5 - 50,0)%\nMetoda miareczkowa","reference":"PN-A-79011-5:1998 p. 2.3","norm_bases":["PN-A-79011-5:1998 p. 2.3"],"lab_section":"Pracownia Analiz Fizyko-chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Koncentraty spożywcze Zawartość cukrów ogółem i cukrów redukujących\nZakres:\nZakres cukry ogółem (5,5 - 85,0)%\nZakres cukry redukujące (2,5 - 50,0)%\nMetoda miareczkowa PN-A-79011-5:1998 p. 2.3 Koncentraty spozywcze Zawartosc cukrow ogolem i cukrow redukujacych\nZakres:\nZakres cukry ogolem (5,5 - 85,0)%\nZakres cukry redukujace (2,5 - 50,0)%\nMetoda miareczkowa PN-A-79011-5:1998 p. 2.3","categories":["other"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total sugars and reducing sugars content","parameters_en":[{"name":"Range total sugars","range":"(5,5 - 85,0)%"},{"name":"Range reducing sugars","range":"(2,5 - 50,0)%"}],"search_en":"Food concentrates Total sugars and reducing sugars content Titrimetric method Range total sugars Range reducing sugars PN-A-79011-5:1998 p. 2.3","technique_en":"Titrimetric method","test_object_en":"Food concentrates","search_zh":"食品浓缩制品 滴定法 PN-A-79011-5:1998 p. 2.3","technique_zh":"滴定法","test_object_zh":"食品浓缩制品"},{"_id":"6a836c58af14b9c0e7b1e35b","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Pieczywo","methodology":"Zawartość cukrów ogółem","parameters":[{"name":"Zakres","range":"(1,8 - 25,0)%"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość cukrów ogółem\nZakres (1,8 - 25,0)%\nMetoda miareczkowa","reference":"PN-A-74108:1996 p.3.7.1 i 3.7.2","norm_bases":["PN-A-74108:1996 p.3.7.1 i 3.7.2"],"lab_section":"Pracownia Analiz Fizyko-chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pieczywo Zawartość cukrów ogółem\nZakres (1,8 - 25,0)%\nMetoda miareczkowa PN-A-74108:1996 p.3.7.1 i 3.7.2 Pieczywo Zawartosc cukrow ogolem\nZakres (1,8 - 25,0)%\nMetoda miareczkowa PN-A-74108:1996 p.3.7.1 i 3.7.2","categories":["other"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total sugar content","parameters_en":[{"name":"Range","range":"(1,8 - 25,0)%"}],"search_en":"Bread Total sugar content Titrimetric method Range PN-A-74108:1996 p.3.7.1 i 3.7.2","technique_en":"Titrimetric method","test_object_en":"Bread","parameters_zh":[{"name":"范围","range":"(1,8 - 25,0)%"}],"search_zh":"面包 总糖含量 滴定法 范围 PN-A-74108:1996 p.3.7.1 i 3.7.2","technique_zh":"滴定法","test_object_zh":"面包","methodology_zh":"总糖含量"},{"_id":"6a836c58af14b9c0e7b1e35c","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Wyroby garmażeryjne","methodology":"Zawartość cukrów ogółem","parameters":[{"name":"Zakres","range":"(0,5 - 10,0) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość cukrów ogółem\nZakres (0,5 - 10,0) %\nMetoda miareczkowa","reference":"PN-85/A-82100 p.2.5","norm_bases":["PN-85/A-82100 p.2.5"],"lab_section":"Pracownia Analiz Fizyko-chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby garmażeryjne Zawartość cukrów ogółem\nZakres (0,5 - 10,0) %\nMetoda miareczkowa PN-85/A-82100 p.2.5 Wyroby garmazeryjne Zawartosc cukrow ogolem\nZakres (0,5 - 10,0) %\nMetoda miareczkowa PN-85/A-82100 p.2.5","categories":["other"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total sugar content","parameters_en":[{"name":"Range","range":"(0,5 - 10,0) %"}],"search_en":"Delicatessen products Total sugar content Titrimetric method Range PN-85/A-82100 p.2.5","technique_en":"Titrimetric method","test_object_en":"Delicatessen products","parameters_zh":[{"name":"范围","range":"(0,5 - 10,0) %"}],"search_zh":"熟食制品 总糖含量 滴定法 范围 PN-85/A-82100 p.2.5","technique_zh":"滴定法","test_object_zh":"熟食制品","methodology_zh":"总糖含量"},{"_id":"6a836c58af14b9c0e7b1e35d","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Wyroby garmażeryjne","methodology":"Zawartość skrobi","parameters":[{"name":"Zakres","range":"(0,5 - 20,0) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość skrobi\nZakres (0,5 - 20,0) %\nMetoda miareczkowa","reference":"MP-00870-PL wersja 3 ważna od 19.02.2020","norm_bases":["MP-00870-PL wersja 3 ważna od 19.02.2020"],"lab_section":"Pracownia Analiz Fizyko-chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby garmażeryjne Zawartość skrobi\nZakres (0,5 - 20,0) %\nMetoda miareczkowa MP-00870-PL wersja 3 ważna od 19.02.2020 Wyroby garmazeryjne Zawartosc skrobi\nZakres (0,5 - 20,0) %\nMetoda miareczkowa MP-00870-PL wersja 3 wazna od 19.02.2020","categories":["other"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Starch content","parameters_en":[{"name":"Range","range":"(0,5 - 20,0) %"}],"search_en":"Delicatessen products Starch content Titrimetric method Range MP-00870-PL wersja 3 ważna od 19.02.2020","technique_en":"Titrimetric method","test_object_en":"Delicatessen products","parameters_zh":[{"name":"范围","range":"(0,5 - 20,0) %"}],"search_zh":"熟食制品 淀粉含量 滴定法 范围 MP-00870-PL wersja 3 ważna od 19.02.2020","technique_zh":"滴定法","test_object_zh":"熟食制品","methodology_zh":"淀粉含量"},{"_id":"6a836c58af14b9c0e7b1e35e","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Mięso i przetwory mięsne","methodology":"Zawartość skrobi","parameters":[{"name":"Zakres","range":"(0,5 - 20,0) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość skrobi\nZakres (0,5 - 20,0) %\nMetoda miareczkowa","reference":"MP-00870-PL wersja 3 ważna od 19.02.2020","norm_bases":["MP-00870-PL wersja 3 ważna od 19.02.2020"],"lab_section":"Pracownia Analiz Fizyko-chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i przetwory mięsne Zawartość skrobi\nZakres (0,5 - 20,0) %\nMetoda miareczkowa MP-00870-PL wersja 3 ważna od 19.02.2020 Mieso i przetwory miesne Zawartosc skrobi\nZakres (0,5 - 20,0) %\nMetoda miareczkowa MP-00870-PL wersja 3 wazna od 19.02.2020","categories":["food"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Starch content","parameters_en":[{"name":"Range","range":"(0,5 - 20,0) %"}],"search_en":"Meat and meat products Starch content Titrimetric method Range MP-00870-PL wersja 3 ważna od 19.02.2020","technique_en":"Titrimetric method","test_object_en":"Meat and meat products","parameters_zh":[{"name":"范围","range":"(0,5 - 20,0) %"}],"search_zh":"肉与肉制品 淀粉含量 滴定法 范围 MP-00870-PL wersja 3 ważna od 19.02.2020","technique_zh":"滴定法","test_object_zh":"肉与肉制品","methodology_zh":"淀粉含量"},{"_id":"6a836c58af14b9c0e7b1e35f","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Wyroby cukiernicze","methodology":"Liczba kwasowa tłuszczu","parameters":[{"name":"Zakres","range":"(0,1 - 10,0) mg KOH/g"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Liczba kwasowa tłuszczu\nZakres (0,1 - 10,0) mg KOH/g\nMetoda miareczkowa","reference":"PN-79/A-88024 p.2.5","norm_bases":["PN-79/A-88024 p.2.5"],"lab_section":"Pracownia Analiz Fizyko-chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby cukiernicze Liczba kwasowa tłuszczu\nZakres (0,1 - 10,0) mg KOH/g\nMetoda miareczkowa PN-79/A-88024 p.2.5 Wyroby cukiernicze Liczba kwasowa tluszczu\nZakres (0,1 - 10,0) mg KOH/g\nMetoda miareczkowa PN-79/A-88024 p.2.5","categories":["food"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Acid value of fat","parameters_en":[{"name":"Range","range":"(0,1 - 10,0) mg KOH/g"}],"search_en":"Confectionery products Acid value of fat Titrimetric method Range PN-79/A-88024 p.2.5","technique_en":"Titrimetric method","test_object_en":"Confectionery products","parameters_zh":[{"name":"范围","range":"(0,1 - 10,0) mg KOH/g"}],"search_zh":"糖果制品 滴定法 范围 PN-79/A-88024 p.2.5","technique_zh":"滴定法","test_object_zh":"糖果制品"},{"_id":"6a836c58af14b9c0e7b1e360","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Wyroby cukiernicze","methodology":"Zawartość cukrów ogółem i cukrów redukujących","parameters":[{"name":"Zakres cukry ogółem","range":"(33 - 99) %"},{"name":"Zakres cukry redukujące","range":"(6,5 - 30,0) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość cukrów ogółem i cukrów redukujących\nZakres:\nZakres cukry ogółem (33 - 99) %\nZakres cukry redukujące (6,5 - 30,0) %\nMetoda miareczkowa","reference":"PN-61/A-88023","norm_bases":["PN-61/A-88023"],"lab_section":"Pracownia Analiz Fizyko-chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby cukiernicze Zawartość cukrów ogółem i cukrów redukujących\nZakres:\nZakres cukry ogółem (33 - 99) %\nZakres cukry redukujące (6,5 - 30,0) %\nMetoda miareczkowa PN-61/A-88023 Wyroby cukiernicze Zawartosc cukrow ogolem i cukrow redukujacych\nZakres:\nZakres cukry ogolem (33 - 99) %\nZakres cukry redukujace (6,5 - 30,0) %\nMetoda miareczkowa PN-61/A-88023","categories":["food"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total sugars and reducing sugars content","parameters_en":[{"name":"Range total sugars","range":"(33 - 99) %"},{"name":"Range reducing sugars","range":"(6,5 - 30,0) %"}],"search_en":"Confectionery products Total sugars and reducing sugars content Titrimetric method Range total sugars Range reducing sugars PN-61/A-88023","technique_en":"Titrimetric method","test_object_en":"Confectionery products","search_zh":"糖果制品 滴定法 PN-61/A-88023","technique_zh":"滴定法","test_object_zh":"糖果制品"},{"_id":"6a836c58af14b9c0e7b1e361","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Wyroby cukiernicze","methodology":"Wygląd ogólny, Konsystencja, Zapach, Smak","parameters":[],"technique":"Prosty test opisowy","techniques":["Prosty test opisowy"],"computed":[],"activity":"Wygląd ogólny, Konsystencja, Zapach, Smak\nProsty test opisowy","reference":"PN-A-88032:1998 p.4.1-4.8","norm_bases":["PN-A-88032:1998 p.4.1-4.8"],"lab_section":"Pracownia Analiz Fizyko-chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby cukiernicze Wygląd ogólny, Konsystencja, Zapach, Smak\nProsty test opisowy PN-A-88032:1998 p.4.1-4.8 Wyroby cukiernicze Wyglad ogolny, Konsystencja, Zapach, Smak\nProsty test opisowy PN-A-88032:1998 p.4.1-4.8","categories":["food"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"General appearance, Consistency, Odour, Taste","search_en":"Confectionery products General appearance, Consistency, Odour, Taste Simple descriptive test PN-A-88032:1998 p.4.1-4.8","technique_en":"Simple descriptive test","test_object_en":"Confectionery products","search_zh":"糖果制品 PN-A-88032:1998 p.4.1-4.8","test_object_zh":"糖果制品"},{"_id":"6a836c58af14b9c0e7b1e362","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Wyroby ciastkarskie","methodology":"Zawartość cukrów ogółem","parameters":[{"name":"Zakres","range":"(3,0 - 60,0)%"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość cukrów ogółem\nZakres (3,0 - 60,0)%\nMetoda miareczkowa","reference":"PN-A-74252:1998 p.3.5.1 i 3.5.3","norm_bases":["PN-A-74252:1998 p.3.5.1 i 3.5.3"],"lab_section":"Pracownia Analiz Fizyko-chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby ciastkarskie Zawartość cukrów ogółem\nZakres (3,0 - 60,0)%\nMetoda miareczkowa PN-A-74252:1998 p.3.5.1 i 3.5.3 Wyroby ciastkarskie Zawartosc cukrow ogolem\nZakres (3,0 - 60,0)%\nMetoda miareczkowa PN-A-74252:1998 p.3.5.1 i 3.5.3","categories":["other"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total sugar content","parameters_en":[{"name":"Range","range":"(3,0 - 60,0)%"}],"search_en":"Bakery products Total sugar content Titrimetric method Range PN-A-74252:1998 p.3.5.1 i 3.5.3","technique_en":"Titrimetric method","test_object_en":"Bakery products","parameters_zh":[{"name":"范围","range":"(3,0 - 60,0)%"}],"search_zh":"糕点制品 总糖含量 滴定法 范围 PN-A-74252:1998 p.3.5.1 i 3.5.3","technique_zh":"滴定法","methodology_zh":"总糖含量","test_object_zh":"糕点制品"},{"_id":"6a836c58af14b9c0e7b1e363","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Wyroby ciastkarskie","methodology":"Wygląd ogólny, Konsystencja, Zapach, Smak","parameters":[],"technique":"Prosty test opisowy","techniques":["Prosty test opisowy"],"computed":[],"activity":"Wygląd ogólny, Konsystencja, Zapach, Smak\nProsty test opisowy","reference":"MP-00886-PL wersja 4 ważna od 20.02.2020","norm_bases":["MP-00886-PL wersja 4 ważna od 20.02.2020"],"lab_section":"Pracownia Analiz Fizyko-chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby ciastkarskie Wygląd ogólny, Konsystencja, Zapach, Smak\nProsty test opisowy MP-00886-PL wersja 4 ważna od 20.02.2020 Wyroby ciastkarskie Wyglad ogolny, Konsystencja, Zapach, Smak\nProsty test opisowy MP-00886-PL wersja 4 wazna od 20.02.2020","categories":["other"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"General appearance, Consistency, Odour, Taste","search_en":"Bakery products General appearance, Consistency, Odour, Taste Simple descriptive test MP-00886-PL wersja 4 ważna od 20.02.2020","technique_en":"Simple descriptive test","test_object_en":"Bakery products","search_zh":"糕点制品 MP-00886-PL wersja 4 ważna od 20.02.2020","test_object_zh":"糕点制品"},{"_id":"6a836c58af14b9c0e7b1e364","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Mleko i produkty mleczne","methodology":"pH","parameters":[{"name":"Zakres","range":"3,00 – 8,00"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 3,00 – 8,00\nMetoda potencjometryczna","reference":"MP-00830-PL wersja 6 ważna od 12.02.2025","norm_bases":["MP-00830-PL wersja 6 ważna od 12.02.2025"],"lab_section":"Pracownia Analiz Fizyko-chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mleko i produkty mleczne pH\nZakres 3,00 – 8,00\nMetoda potencjometryczna MP-00830-PL wersja 6 ważna od 12.02.2025 Mleko i produkty mleczne pH\nZakres 3,00 – 8,00\nMetoda potencjometryczna MP-00830-PL wersja 6 wazna od 12.02.2025","categories":["food"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"3,00 – 8,00"}],"search_en":"Milk and milk products pH Potentiometric method Range MP-00830-PL wersja 6 ważna od 12.02.2025","technique_en":"Potentiometric method","test_object_en":"Milk and milk products","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"3,00 – 8,00"}],"search_zh":"乳与乳制品 pH 值 电位法 范围 MP-00830-PL wersja 6 ważna od 12.02.2025","technique_zh":"电位法","test_object_zh":"乳与乳制品"},{"_id":"6a836c58af14b9c0e7b1e365","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Przetwory rybne","methodology":"pH","parameters":[{"name":"Zakres","range":"2,00 – 8,00"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,00 – 8,00\nMetoda potencjometryczna","reference":"PN-87/A-86782 p. 2.4.15","norm_bases":["PN-87/A-86782 p. 2.4.15"],"lab_section":"Pracownia Analiz Fizyko-chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przetwory rybne pH\nZakres 2,00 – 8,00\nMetoda potencjometryczna PN-87/A-86782 p. 2.4.15 Przetwory rybne pH\nZakres 2,00 – 8,00\nMetoda potencjometryczna PN-87/A-86782 p. 2.4.15","categories":["other"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,00 – 8,00"}],"search_en":"Fish products pH Potentiometric method Range PN-87/A-86782 p. 2.4.15","technique_en":"Potentiometric method","test_object_en":"Fish products","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,00 – 8,00"}],"search_zh":"鱼制品 pH 值 电位法 范围 PN-87/A-86782 p. 2.4.15","technique_zh":"电位法","test_object_zh":"鱼制品"},{"_id":"6a836c58af14b9c0e7b1e366","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Kakao","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-79/A-88024","norm_bases":["PN-79/A-88024"],"lab_section":"Pracownia Analiz Fizyko-chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kakao pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-79/A-88024 Kakao pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-79/A-88024","categories":["other"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"search_en":"Cocoa pH Potentiometric method Range PN-79/A-88024","technique_en":"Potentiometric method","test_object_en":"Cocoa","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"pH 值 电位法 范围 PN-79/A-88024","technique_zh":"电位法"},{"_id":"6a836c58af14b9c0e7b1e367","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Miód","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(0,08 - 3,00) mS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (0,08 - 3,00) mS/cm\nMetoda konduktometryczna","reference":"PN-88/A-77626 p.5.3.10","norm_bases":["PN-88/A-77626 p.5.3.10"],"lab_section":"Pracownia Analiz Fizyko-chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Miód Przewodność elektryczna właściwa\nZakres (0,08 - 3,00) mS/cm\nMetoda konduktometryczna PN-88/A-77626 p.5.3.10 Miod Przewodnosc elektryczna wlasciwa\nZakres (0,08 - 3,00) mS/cm\nMetoda konduktometryczna PN-88/A-77626 p.5.3.10","categories":["other"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(0,08 - 3,00) mS/cm"}],"search_en":"Honey Electrical conductivity Conductometric method Range PN-88/A-77626 p.5.3.10","technique_en":"Conductometric method","test_object_en":"Honey","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(0,08 - 3,00) mS/cm"}],"search_zh":"蜂蜜 电导率 电导法 范围 PN-88/A-77626 p.5.3.10","technique_zh":"电导法","test_object_zh":"蜂蜜"},{"_id":"6a836c58af14b9c0e7b1e368","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Napoje bezalkoholowe","methodology":"Zawartość ekstraktu ogólnego","parameters":[{"name":"Zakres","range":"(0,3 - 85,0)%"}],"technique":"Metoda refraktometryczna","techniques":["Metoda refraktometryczna"],"computed":[],"activity":"Zawartość ekstraktu ogólnego\nZakres (0,3 - 85,0)%\nMetoda refraktometryczna","reference":"PN-85/A-79033 p. 3.6.1","norm_bases":["PN-85/A-79033 p. 3.6.1"],"lab_section":"Pracownia Analiz Fizyko-chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Napoje bezalkoholowe Zawartość ekstraktu ogólnego\nZakres (0,3 - 85,0)%\nMetoda refraktometryczna PN-85/A-79033 p. 3.6.1 Napoje bezalkoholowe Zawartosc ekstraktu ogolnego\nZakres (0,3 - 85,0)%\nMetoda refraktometryczna PN-85/A-79033 p. 3.6.1","categories":["food"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total extract content","parameters_en":[{"name":"Range","range":"(0,3 - 85,0)%"}],"search_en":"Non-alcoholic beverages Total extract content Refractometric method Range PN-85/A-79033 p. 3.6.1","technique_en":"Refractometric method","test_object_en":"Non-alcoholic beverages","parameters_zh":[{"name":"范围","range":"(0,3 - 85,0)%"}],"search_zh":"无酒精饮料 总浸出物含量 折射法 范围 PN-85/A-79033 p. 3.6.1","technique_zh":"折射法","test_object_zh":"无酒精饮料","methodology_zh":"总浸出物含量"},{"_id":"6a836c58af14b9c0e7b1e369","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Napoje bezalkoholowe","methodology":"Klarowność, Barwa, Zapach, Smak","parameters":[],"technique":"Prosty test opisowy","techniques":["Prosty test opisowy"],"computed":[],"activity":"Klarowność, Barwa, Zapach, Smak\nProsty test opisowy","reference":"PN-85/A-79033 p.3.4 i 3.5","norm_bases":["PN-85/A-79033 p.3.4 i 3.5"],"lab_section":"Pracownia Analiz Fizyko-chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Napoje bezalkoholowe Klarowność, Barwa, Zapach, Smak\nProsty test opisowy PN-85/A-79033 p.3.4 i 3.5 Napoje bezalkoholowe Klarownosc, Barwa, Zapach, Smak\nProsty test opisowy PN-85/A-79033 p.3.4 i 3.5","categories":["food"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Clarity, Colour, Odour, Taste","search_en":"Non-alcoholic beverages Clarity, Colour, Odour, Taste Simple descriptive test PN-85/A-79033 p.3.4 i 3.5","technique_en":"Simple descriptive test","test_object_en":"Non-alcoholic beverages","search_zh":"无酒精饮料 PN-85/A-79033 p.3.4 i 3.5","test_object_zh":"无酒精饮料"},{"_id":"6a836c58af14b9c0e7b1e36a","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Napoje bezalkoholowe, Napoje alkoholowe","methodology":"Zawartość dwutlenku węgla","parameters":[{"name":"Zakres","range":"(2,5 – 10,0)g/l"}],"technique":"Metoda ciśnieniowa","techniques":["Metoda ciśnieniowa"],"computed":[],"activity":"Zawartość dwutlenku węgla\nZakres (2,5 – 10,0)g/l\nMetoda ciśnieniowa","reference":"MP-03653-PL wersja 1 ważna od 05.09.2024","norm_bases":["MP-03653-PL wersja 1 ważna od 05.09.2024"],"lab_section":"Pracownia Analiz Fizyko-chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Napoje bezalkoholowe, Napoje alkoholowe Zawartość dwutlenku węgla\nZakres (2,5 – 10,0)g/l\nMetoda ciśnieniowa MP-03653-PL wersja 1 ważna od 05.09.2024 Napoje bezalkoholowe, Napoje alkoholowe Zawartosc dwutlenku wegla\nZakres (2,5 – 10,0)g/l\nMetoda cisnieniowa MP-03653-PL wersja 1 wazna od 05.09.2024","categories":["food"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Carbon dioxide content","parameters_en":[{"name":"Range","range":"(2,5 – 10,0)g/l"}],"search_en":"Non-alcoholic beverages, Alcoholic beverages Carbon dioxide content Pressure method Range MP-03653-PL wersja 1 ważna od 05.09.2024","technique_en":"Pressure method","test_object_en":"Non-alcoholic beverages, Alcoholic beverages","parameters_zh":[{"name":"范围","range":"(2,5 – 10,0)g/l"}],"search_zh":"二氧化碳含量 压力法 范围 MP-03653-PL wersja 1 ważna od 05.09.2024","technique_zh":"压力法","methodology_zh":"二氧化碳含量"},{"_id":"6a836c58af14b9c0e7b1e36b","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Soki owocowe i warzywne","methodology":"pH","parameters":[{"name":"Zakres","range":"2,00 – 8,00"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,00 – 8,00\nMetoda potencjometryczna","reference":"PN-EN 1132:1999","norm_bases":["PN-EN 1132:1999"],"lab_section":"Pracownia Analiz Fizyko-chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Soki owocowe i warzywne pH\nZakres 2,00 – 8,00\nMetoda potencjometryczna PN-EN 1132:1999 Soki owocowe i warzywne pH\nZakres 2,00 – 8,00\nMetoda potencjometryczna PN-EN 1132:1999","categories":["other"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,00 – 8,00"}],"search_en":"Fruit and vegetable juices pH Potentiometric method Range PN-EN 1132:1999","technique_en":"Potentiometric method","test_object_en":"Fruit and vegetable juices","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,00 – 8,00"}],"search_zh":"果汁与蔬菜汁 pH 值 电位法 范围 PN-EN 1132:1999","technique_zh":"电位法","test_object_zh":"果汁与蔬菜汁"},{"_id":"6a836c58af14b9c0e7b1e36c","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Soki owocowe i warzywne","methodology":"Zawartość ekstraktu","parameters":[{"name":"Zakres","range":"(1 – 60) %"}],"technique":"Metoda refraktometryczna","techniques":["Metoda refraktometryczna"],"computed":[],"activity":"Zawartość ekstraktu\nZakres (1 – 60) %\nMetoda refraktometryczna","reference":"PN-EN 12143:2000","norm_bases":["PN-EN 12143:2000"],"lab_section":"Pracownia Analiz Fizyko-chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Soki owocowe i warzywne Zawartość ekstraktu\nZakres (1 – 60) %\nMetoda refraktometryczna PN-EN 12143:2000 Soki owocowe i warzywne Zawartosc ekstraktu\nZakres (1 – 60) %\nMetoda refraktometryczna PN-EN 12143:2000","categories":["other"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Extract content","parameters_en":[{"name":"Range","range":"(1 – 60) %"}],"search_en":"Fruit and vegetable juices Extract content Refractometric method Range PN-EN 12143:2000","technique_en":"Refractometric method","test_object_en":"Fruit and vegetable juices","parameters_zh":[{"name":"范围","range":"(1 – 60) %"}],"search_zh":"果汁与蔬菜汁 浸出物含量 折射法 范围 PN-EN 12143:2000","technique_zh":"折射法","test_object_zh":"果汁与蔬菜汁","methodology_zh":"浸出物含量"},{"_id":"6a836c58af14b9c0e7b1e36d","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Soki owocowe i warzywne","methodology":"Wygląd, Barwa, Zapach, Smak","parameters":[],"technique":"Prosty test opisowy","techniques":["Prosty test opisowy"],"computed":[],"activity":"Wygląd, Barwa, Zapach, Smak\nProsty test opisowy","reference":"MP-00889-PL wersja 4 ważna od 20.02.2020","norm_bases":["MP-00889-PL wersja 4 ważna od 20.02.2020"],"lab_section":"Pracownia Analiz Fizyko-chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Soki owocowe i warzywne Wygląd, Barwa, Zapach, Smak\nProsty test opisowy MP-00889-PL wersja 4 ważna od 20.02.2020 Soki owocowe i warzywne Wyglad, Barwa, Zapach, Smak\nProsty test opisowy MP-00889-PL wersja 4 wazna od 20.02.2020","categories":["other"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Appearance, Colour, Odour, Taste","search_en":"Fruit and vegetable juices Appearance, Colour, Odour, Taste Simple descriptive test MP-00889-PL wersja 4 ważna od 20.02.2020","technique_en":"Simple descriptive test","test_object_en":"Fruit and vegetable juices","search_zh":"果汁与蔬菜汁 MP-00889-PL wersja 4 ważna od 20.02.2020","test_object_zh":"果汁与蔬菜汁"},{"_id":"6a836c58af14b9c0e7b1e36e","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Przetwory owocowe i warzywne","methodology":"Zawartość ekstraktu ogólnego","parameters":[{"name":"Zakres","range":"(1 - 85)%"}],"technique":"Metoda refraktometryczna","techniques":["Metoda refraktometryczna"],"computed":[],"activity":"Zawartość ekstraktu ogólnego\nZakres (1 - 85)%\nMetoda refraktometryczna","reference":"PN-90/A-75101/02+Az1:2002","norm_bases":["PN-90/A-75101/02+Az1:2002"],"lab_section":"Pracownia Analiz Fizyko-chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przetwory owocowe i warzywne Zawartość ekstraktu ogólnego\nZakres (1 - 85)%\nMetoda refraktometryczna PN-90/A-75101/02+Az1:2002 Przetwory owocowe i warzywne Zawartosc ekstraktu ogolnego\nZakres (1 - 85)%\nMetoda refraktometryczna PN-90/A-75101/02+Az1:2002","categories":["other"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total extract content","parameters_en":[{"name":"Range","range":"(1 - 85)%"}],"search_en":"Fruit and vegetable preserves Total extract content Refractometric method Range PN-90/A-75101/02+Az1:2002","technique_en":"Refractometric method","test_object_en":"Fruit and vegetable preserves","parameters_zh":[{"name":"范围","range":"(1 - 85)%"}],"search_zh":"水果与蔬菜腌渍制品 总浸出物含量 折射法 范围 PN-90/A-75101/02+Az1:2002","technique_zh":"折射法","methodology_zh":"总浸出物含量","test_object_zh":"水果与蔬菜腌渍制品"},{"_id":"6a836c58af14b9c0e7b1e36f","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Przetwory owocowe i warzywne","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 8,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 8,0\nMetoda potencjometryczna","reference":"PN-90/A-75101/06+Az1:2002","norm_bases":["PN-90/A-75101/06+Az1:2002"],"lab_section":"Pracownia Analiz Fizyko-chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przetwory owocowe i warzywne pH\nZakres 2,0 – 8,0\nMetoda potencjometryczna PN-90/A-75101/06+Az1:2002 Przetwory owocowe i warzywne pH\nZakres 2,0 – 8,0\nMetoda potencjometryczna PN-90/A-75101/06+Az1:2002","categories":["other"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 – 8,0"}],"search_en":"Fruit and vegetable preserves pH Potentiometric method Range PN-90/A-75101/06+Az1:2002","technique_en":"Potentiometric method","test_object_en":"Fruit and vegetable preserves","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 8,0"}],"search_zh":"水果与蔬菜腌渍制品 pH 值 电位法 范围 PN-90/A-75101/06+Az1:2002","technique_zh":"电位法","test_object_zh":"水果与蔬菜腌渍制品"},{"_id":"6a836c58af14b9c0e7b1e370","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Przetwory owocowe i warzywne","methodology":"Zawartość cukrów ogółem i cukrów redukujących","parameters":[{"name":"Zakres cukry ogółem","range":"(2,5 - 80,0)%"},{"name":"Zakres cukry redukujące","range":"(2,5 - 60,0)%"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość cukrów ogółem i cukrów redukujących\nZakres:\nZakres cukry ogółem (2,5 - 80,0)%\nZakres cukry redukujące (2,5 - 60,0)%\nMetoda miareczkowa","reference":"PN-90/A-75101/07p.2","norm_bases":["PN-90/A-75101/07p.2"],"lab_section":"Pracownia Analiz Fizyko-chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przetwory owocowe i warzywne Zawartość cukrów ogółem i cukrów redukujących\nZakres:\nZakres cukry ogółem (2,5 - 80,0)%\nZakres cukry redukujące (2,5 - 60,0)%\nMetoda miareczkowa PN-90/A-75101/07p.2 Przetwory owocowe i warzywne Zawartosc cukrow ogolem i cukrow redukujacych\nZakres:\nZakres cukry ogolem (2,5 - 80,0)%\nZakres cukry redukujace (2,5 - 60,0)%\nMetoda miareczkowa PN-90/A-75101/07p.2","categories":["other"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total sugars and reducing sugars content","parameters_en":[{"name":"Range total sugars","range":"(2,5 - 80,0)%"},{"name":"Range reducing sugars","range":"(2,5 - 60,0)%"}],"search_en":"Fruit and vegetable preserves Total sugars and reducing sugars content Titrimetric method Range total sugars Range reducing sugars PN-90/A-75101/07p.2","technique_en":"Titrimetric method","test_object_en":"Fruit and vegetable preserves","search_zh":"水果与蔬菜腌渍制品 滴定法 PN-90/A-75101/07p.2","technique_zh":"滴定法","test_object_zh":"水果与蔬菜腌渍制品"},{"_id":"6a836c58af14b9c0e7b1e371","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Przetwory owocowe i warzywne","methodology":"Zawartość ekstraktu bezcukrowego [%], Zawartość ekstraktu bezcukrowego [g/l] (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość ekstraktu bezcukrowego [%], Zawartość ekstraktu bezcukrowego [g/l] (z obliczeń)","reference":"PN-90/A-75101/07p.3","norm_bases":["PN-90/A-75101/07p.3"],"lab_section":"Pracownia Analiz Fizyko-chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przetwory owocowe i warzywne Zawartość ekstraktu bezcukrowego [%], Zawartość ekstraktu bezcukrowego [g/l] (z obliczeń) PN-90/A-75101/07p.3 Przetwory owocowe i warzywne Zawartosc ekstraktu bezcukrowego [%], Zawartosc ekstraktu bezcukrowego [g/l] (z obliczen) PN-90/A-75101/07p.3","categories":["other"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sugar-free extract content [%], Sugar-free extract content [g/l] (calculated)","search_en":"Fruit and vegetable preserves Sugar-free extract content [%], Sugar-free extract content [g/l] (calculated) PN-90/A-75101/07p.3","test_object_en":"Fruit and vegetable preserves","search_zh":"水果与蔬菜腌渍制品 PN-90/A-75101/07p.3","test_object_zh":"水果与蔬菜腌渍制品"},{"_id":"6a836c58af14b9c0e7b1e372","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Przetwory owocowe i warzywne","methodology":"Zawartość dwutlenku siarki","parameters":[{"name":"Zakres","range":"(10 - 2500)mg/kg"}],"technique":"Metoda destylacyjno - miareczkowa","techniques":["Metoda destylacyjno - miareczkowa"],"computed":[],"activity":"Zawartość dwutlenku siarki\nZakres (10 - 2500)mg/kg\nMetoda destylacyjno - miareczkowa","reference":"PN-90/A-75101/23+Az2:2002","norm_bases":["PN-90/A-75101/23+Az2:2002"],"lab_section":"Pracownia Analiz Fizyko-chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przetwory owocowe i warzywne Zawartość dwutlenku siarki\nZakres (10 - 2500)mg/kg\nMetoda destylacyjno - miareczkowa PN-90/A-75101/23+Az2:2002 Przetwory owocowe i warzywne Zawartosc dwutlenku siarki\nZakres (10 - 2500)mg/kg\nMetoda destylacyjno - miareczkowa PN-90/A-75101/23+Az2:2002","categories":["other"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfur dioxide content","parameters_en":[{"name":"Range","range":"(10 - 2500)mg/kg"}],"search_en":"Fruit and vegetable preserves Sulfur dioxide content Distillation - titrimetric method Range PN-90/A-75101/23+Az2:2002","technique_en":"Distillation - titrimetric method","test_object_en":"Fruit and vegetable preserves","parameters_zh":[{"name":"范围","range":"(10 - 2500)mg/kg"}],"search_zh":"水果与蔬菜腌渍制品 二氧化硫含量 范围 PN-90/A-75101/23+Az2:2002","methodology_zh":"二氧化硫含量","test_object_zh":"水果与蔬菜腌渍制品"},{"_id":"6a836c58af14b9c0e7b1e373","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Przetwory owocowe i warzywne","methodology":"Wygląd ogólny, Barwa, Konsystencja, Zapach, Smak","parameters":[],"technique":"Prosty test opisowy","techniques":["Prosty test opisowy"],"computed":[],"activity":"Wygląd ogólny, Barwa, Konsystencja, Zapach, Smak\nProsty test opisowy","reference":"MP-00887-PL wersja 4 ważna od 20.02.2020","norm_bases":["MP-00887-PL wersja 4 ważna od 20.02.2020"],"lab_section":"Pracownia Analiz Fizyko-chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przetwory owocowe i warzywne Wygląd ogólny, Barwa, Konsystencja, Zapach, Smak\nProsty test opisowy MP-00887-PL wersja 4 ważna od 20.02.2020 Przetwory owocowe i warzywne Wyglad ogolny, Barwa, Konsystencja, Zapach, Smak\nProsty test opisowy MP-00887-PL wersja 4 wazna od 20.02.2020","categories":["other"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"General appearance, Colour, Consistency, Odour, Taste","search_en":"Fruit and vegetable preserves General appearance, Colour, Consistency, Odour, Taste Simple descriptive test MP-00887-PL wersja 4 ważna od 20.02.2020","technique_en":"Simple descriptive test","test_object_en":"Fruit and vegetable preserves","search_zh":"水果与蔬菜腌渍制品 MP-00887-PL wersja 4 ważna od 20.02.2020","test_object_zh":"水果与蔬菜腌渍制品"},{"_id":"6a836c58af14b9c0e7b1e374","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Oleje i tłuszcze roślinne oraz zwierzęce","methodology":"Liczba nadtlenkowa","parameters":[{"name":"Zakres","range":"(0,1 - 30,0) meq O2/kg"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Liczba nadtlenkowa\nZakres (0,1 - 30,0) meq O2/kg\nMetoda miareczkowa","reference":"PN-EN ISO 3960:2017-03","norm_bases":["PN-EN ISO 3960:2017-03"],"lab_section":"Pracownia Analiz Fizyko-chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Oleje i tłuszcze roślinne oraz zwierzęce Liczba nadtlenkowa\nZakres (0,1 - 30,0) meq O2/kg\nMetoda miareczkowa PN-EN ISO 3960:2017-03 Oleje i tluszcze roslinne oraz zwierzece Liczba nadtlenkowa\nZakres (0,1 - 30,0) meq O2/kg\nMetoda miareczkowa PN-EN ISO 3960:2017-03","categories":["food","petro"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Peroxide value","parameters_en":[{"name":"Range","range":"(0,1 - 30,0) meq O2/kg"}],"search_en":"Vegetable and animal oils and fats Peroxide value Titrimetric method Range PN-EN ISO 3960:2017-03","technique_en":"Titrimetric method","test_object_en":"Vegetable and animal oils and fats","parameters_zh":[{"name":"范围","range":"(0,1 - 30,0) meq O2/kg"}],"search_zh":"植物油脂与动物油脂 过氧化值 滴定法 范围 PN-EN ISO 3960:2017-03","technique_zh":"滴定法","methodology_zh":"过氧化值","test_object_zh":"植物油脂与动物油脂"},{"_id":"6a836c58af14b9c0e7b1e375","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Oleje i tłuszcze roślinne oraz zwierzęce","methodology":"Liczba nadtlenkowa","parameters":[{"name":"Zakres","range":"(0,25 - 30,0) meq O2/kg"}],"technique":"Metoda miareczkowania potencjometrycznego","techniques":["Metoda miareczkowania potencjometrycznego"],"computed":[],"activity":"Liczba nadtlenkowa\nZakres (0,25 - 30,0) meq O2/kg\nMetoda miareczkowania potencjometrycznego","reference":"PN-EN ISO 27107:2012","norm_bases":["PN-EN ISO 27107:2012"],"lab_section":"Pracownia Analiz Fizyko-chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Oleje i tłuszcze roślinne oraz zwierzęce Liczba nadtlenkowa\nZakres (0,25 - 30,0) meq O2/kg\nMetoda miareczkowania potencjometrycznego PN-EN ISO 27107:2012 Oleje i tluszcze roslinne oraz zwierzece Liczba nadtlenkowa\nZakres (0,25 - 30,0) meq O2/kg\nMetoda miareczkowania potencjometrycznego PN-EN ISO 27107:2012","categories":["food","petro"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Peroxide value","parameters_en":[{"name":"Range","range":"(0,25 - 30,0) meq O2/kg"}],"search_en":"Vegetable and animal oils and fats Peroxide value Potentiometric titration method Range PN-EN ISO 27107:2012","technique_en":"Potentiometric titration method","test_object_en":"Vegetable and animal oils and fats","parameters_zh":[{"name":"范围","range":"(0,25 - 30,0) meq O2/kg"}],"search_zh":"植物油脂与动物油脂 过氧化值 电位滴定法 范围 PN-EN ISO 27107:2012","technique_zh":"电位滴定法","methodology_zh":"过氧化值","test_object_zh":"植物油脂与动物油脂"},{"_id":"6a836c58af14b9c0e7b1e376","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Oleje i tłuszcze roślinne oraz zwierzęce","methodology":"Liczba kwasowa tłuszczu","parameters":[{"name":"Zakres","range":"(0,1 - 30,0) mg KOH/g"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Liczba kwasowa tłuszczu\nZakres (0,1 - 30,0) mg KOH/g\nMetoda miareczkowa","reference":"PN-EN ISO 660:2021-03","norm_bases":["PN-EN ISO 660:2021-03"],"lab_section":"Pracownia Analiz Fizyko-chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Oleje i tłuszcze roślinne oraz zwierzęce Liczba kwasowa tłuszczu\nZakres (0,1 - 30,0) mg KOH/g\nMetoda miareczkowa PN-EN ISO 660:2021-03 Oleje i tluszcze roslinne oraz zwierzece Liczba kwasowa tluszczu\nZakres (0,1 - 30,0) mg KOH/g\nMetoda miareczkowa PN-EN ISO 660:2021-03","categories":["food","petro"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Acid value of fat","parameters_en":[{"name":"Range","range":"(0,1 - 30,0) mg KOH/g"}],"search_en":"Vegetable and animal oils and fats Acid value of fat Titrimetric method Range PN-EN ISO 660:2021-03","technique_en":"Titrimetric method","test_object_en":"Vegetable and animal oils and fats","parameters_zh":[{"name":"范围","range":"(0,1 - 30,0) mg KOH/g"}],"search_zh":"植物油脂与动物油脂 滴定法 范围 PN-EN ISO 660:2021-03","technique_zh":"滴定法","test_object_zh":"植物油脂与动物油脂"},{"_id":"6a836c58af14b9c0e7b1e377","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Oleje i tłuszcze roślinne oraz zwierzęce","methodology":"Kwasowość tłuszczu","parameters":[{"name":"Zakres","range":"(0,1 - 10,0) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Kwasowość tłuszczu\nZakres (0,1 - 10,0) %\nMetoda miareczkowa","reference":"PN-EN ISO 660:2021-03","norm_bases":["PN-EN ISO 660:2021-03"],"lab_section":"Pracownia Analiz Fizyko-chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Oleje i tłuszcze roślinne oraz zwierzęce Kwasowość tłuszczu\nZakres (0,1 - 10,0) %\nMetoda miareczkowa PN-EN ISO 660:2021-03 Oleje i tluszcze roslinne oraz zwierzece Kwasowosc tluszczu\nZakres (0,1 - 10,0) %\nMetoda miareczkowa PN-EN ISO 660:2021-03","categories":["food","petro"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Acidity of fat","parameters_en":[{"name":"Range","range":"(0,1 - 10,0) %"}],"search_en":"Vegetable and animal oils and fats Acidity of fat Titrimetric method Range PN-EN ISO 660:2021-03","technique_en":"Titrimetric method","test_object_en":"Vegetable and animal oils and fats","parameters_zh":[{"name":"范围","range":"(0,1 - 10,0) %"}],"search_zh":"植物油脂与动物油脂 脂肪酸度 滴定法 范围 PN-EN ISO 660:2021-03","technique_zh":"滴定法","test_object_zh":"植物油脂与动物油脂","methodology_zh":"脂肪酸度"},{"_id":"6a836c58af14b9c0e7b1e378","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Oleje i tłuszcze roślinne oraz zwierzęce","methodology":"Liczba anizydynowa","parameters":[{"name":"Zakres","range":"(0,5-25,0)"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Liczba anizydynowa\nZakres (0,5-25,0)\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6885:2016-04","norm_bases":["PN-EN ISO 6885:2016-04"],"lab_section":"Pracownia Analiz Fizyko-chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Oleje i tłuszcze roślinne oraz zwierzęce Liczba anizydynowa\nZakres (0,5-25,0)\nMetoda spektrofotometryczna PN-EN ISO 6885:2016-04 Oleje i tluszcze roslinne oraz zwierzece Liczba anizydynowa\nZakres (0,5-25,0)\nMetoda spektrofotometryczna PN-EN ISO 6885:2016-04","categories":["food","petro"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Anisidine value","parameters_en":[{"name":"Range","range":"(0,5-25,0)"}],"search_en":"Vegetable and animal oils and fats Anisidine value Spectrophotometric method Range PN-EN ISO 6885:2016-04","technique_en":"Spectrophotometric method","test_object_en":"Vegetable and animal oils and fats","parameters_zh":[{"name":"范围","range":"(0,5-25,0)"}],"search_zh":"植物油脂与动物油脂 茴香胺值 分光光度法 范围 PN-EN ISO 6885:2016-04","technique_zh":"分光光度法","test_object_zh":"植物油脂与动物油脂","methodology_zh":"茴香胺值"},{"_id":"6a836c58af14b9c0e7b1e379","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Wędliny","methodology":"Wygląd ogólny, Konsystencja, Barwa, Zapach, Smak","parameters":[],"technique":"Prosty test opisowy","techniques":["Prosty test opisowy"],"computed":[],"activity":"Wygląd ogólny, Konsystencja, Barwa, Zapach, Smak\nProsty test opisowy","reference":"MP-00890-PL wersja 4 ważna od 20.02.2020","norm_bases":["MP-00890-PL wersja 4 ważna od 20.02.2020"],"lab_section":"Pracownia Analiz Fizyko-chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wędliny Wygląd ogólny, Konsystencja, Barwa, Zapach, Smak\nProsty test opisowy MP-00890-PL wersja 4 ważna od 20.02.2020 Wedliny Wyglad ogolny, Konsystencja, Barwa, Zapach, Smak\nProsty test opisowy MP-00890-PL wersja 4 wazna od 20.02.2020","categories":["other"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"General appearance, Consistency, Colour, Odour, Taste","search_en":"Cured meat products General appearance, Consistency, Colour, Odour, Taste Simple descriptive test MP-00890-PL wersja 4 ważna od 20.02.2020","technique_en":"Simple descriptive test","test_object_en":"Cured meat products"},{"_id":"6a836c58af14b9c0e7b1e37a","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Płatki i mieszanki śniadaniowe, musli","methodology":"Wygląd ogólny, Barwa, Konsystencja, Zapach, Smak","parameters":[],"technique":"Prosty test opisowy","techniques":["Prosty test opisowy"],"computed":[],"activity":"Wygląd ogólny, Barwa, Konsystencja, Zapach, Smak\nProsty test opisowy","reference":"MP-00892-PL wersja 3 ważna od 20.02.2020","norm_bases":["MP-00892-PL wersja 3 ważna od 20.02.2020"],"lab_section":"Pracownia Analiz Fizyko-chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Płatki i mieszanki śniadaniowe, musli Wygląd ogólny, Barwa, Konsystencja, Zapach, Smak\nProsty test opisowy MP-00892-PL wersja 3 ważna od 20.02.2020 Platki i mieszanki sniadaniowe, musli Wyglad ogolny, Barwa, Konsystencja, Zapach, Smak\nProsty test opisowy MP-00892-PL wersja 3 wazna od 20.02.2020","categories":["other"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"General appearance, Colour, Consistency, Odour, Taste","search_en":"Breakfast cereals and mixes, muesli General appearance, Colour, Consistency, Odour, Taste Simple descriptive test MP-00892-PL wersja 3 ważna od 20.02.2020","technique_en":"Simple descriptive test","test_object_en":"Breakfast cereals and mixes, muesli"},{"_id":"6a836c58af14b9c0e7b1e37b","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Bakalie, pestki dyni, ziarno słonecznika","methodology":"Wygląd ogólny, Barwa, Konsystencja, Zapach, Smak","parameters":[],"technique":"Prosty test opisowy","techniques":["Prosty test opisowy"],"computed":[],"activity":"Wygląd ogólny, Barwa, Konsystencja, Zapach, Smak\nProsty test opisowy","reference":"MP-00894-PL wersja 3 ważna od 20.02.2020","norm_bases":["MP-00894-PL wersja 3 ważna od 20.02.2020"],"lab_section":"Pracownia Analiz Fizyko-chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Bakalie, pestki dyni, ziarno słonecznika Wygląd ogólny, Barwa, Konsystencja, Zapach, Smak\nProsty test opisowy MP-00894-PL wersja 3 ważna od 20.02.2020 Bakalie, pestki dyni, ziarno slonecznika Wyglad ogolny, Barwa, Konsystencja, Zapach, Smak\nProsty test opisowy MP-00894-PL wersja 3 wazna od 20.02.2020","categories":["other"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"General appearance, Colour, Consistency, Odour, Taste","search_en":"Dried fruits, pumpkin seeds, sunflower seeds General appearance, Colour, Consistency, Odour, Taste Simple descriptive test MP-00894-PL wersja 3 ważna od 20.02.2020","technique_en":"Simple descriptive test","test_object_en":"Dried fruits, pumpkin seeds, sunflower seeds"},{"_id":"6a836c58af14b9c0e7b1e37c","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie chloru wolnego","parameters":[{"name":"Zakres","range":"(0,04 – 1,4) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chloru wolnego\nZakres (0,04 – 1,4) mg/l\nMetoda spektrofotometryczna","reference":"MP-00840-PL wersja 6 ważna od 12.02.2025","norm_bases":["MP-00840-PL wersja 6 ważna od 12.02.2025"],"lab_section":"Pracownia Analiz Fizyko-chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie chloru wolnego\nZakres (0,04 – 1,4) mg/l\nMetoda spektrofotometryczna MP-00840-PL wersja 6 ważna od 12.02.2025 Woda do spozycia przez ludzi Stezenie chloru wolnego\nZakres (0,04 – 1,4) mg/l\nMetoda spektrofotometryczna MP-00840-PL wersja 6 wazna od 12.02.2025","categories":["water"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free chlorine concentration","parameters_en":[{"name":"Range","range":"(0,04 – 1,4) mg/l"}],"search_en":"Water intended for human consumption Free chlorine concentration Spectrophotometric method Range MP-00840-PL wersja 6 ważna od 12.02.2025","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","methodology_zh":"游离氯浓度","parameters_zh":[{"name":"范围","range":"(0,04 – 1,4) mg/l"}],"search_zh":"生活饮用水 游离氯浓度 分光光度法 范围 MP-00840-PL wersja 6 ważna od 12.02.2025","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a836c58af14b9c0e7b1e37d","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Pracownia Analiz Fizyko-chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda do spozycia przez ludzi pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"search_en":"Water intended for human consumption pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water intended for human consumption","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"生活饮用水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"生活饮用水"},{"_id":"6a836c58af14b9c0e7b1e37e","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(140 - 2500) µS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (140 - 2500) µS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Pracownia Analiz Fizyko-chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Przewodność elektryczna właściwa\nZakres (140 - 2500) µS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa\nZakres (140 - 2500) µS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(140 - 2500) µS/cm"}],"search_en":"Water intended for human consumption Electrical conductivity Conductometric method Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water intended for human consumption","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(140 - 2500) µS/cm"}],"search_zh":"生活饮用水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"生活饮用水"},{"_id":"6a836c58af14b9c0e7b1e37f","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie jonu amonowego","parameters":[{"name":"Zakres","range":"(0,03 - 3,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie jonu amonowego\nZakres (0,03 - 3,00) mg/l\nMetoda spektrofotometryczna","reference":"MP-00869-PL wersja 7 ważna od 12.02.2025","norm_bases":["MP-00869-PL wersja 7 ważna od 12.02.2025"],"lab_section":"Pracownia Analiz Fizyko-chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie jonu amonowego\nZakres (0,03 - 3,00) mg/l\nMetoda spektrofotometryczna MP-00869-PL wersja 7 ważna od 12.02.2025 Woda do spozycia przez ludzi Stezenie jonu amonowego\nZakres (0,03 - 3,00) mg/l\nMetoda spektrofotometryczna MP-00869-PL wersja 7 wazna od 12.02.2025","categories":["water"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium ion concentration","parameters_en":[{"name":"Range","range":"(0,03 - 3,00) mg/l"}],"search_en":"Water intended for human consumption Ammonium ion concentration Spectrophotometric method Range MP-00869-PL wersja 7 ważna od 12.02.2025","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","methodology_zh":"铵离子浓度","parameters_zh":[{"name":"范围","range":"(0,03 - 3,00) mg/l"}],"search_zh":"生活饮用水 铵离子浓度 分光光度法 范围 MP-00869-PL wersja 7 ważna od 12.02.2025","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a836c58af14b9c0e7b1e380","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,1 - 100,0) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,1 - 100,0) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":"Pracownia Analiz Fizyko-chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Mętność\nZakres (0,1 - 100,0) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda do spozycia przez ludzi Metnosc\nZakres (0,1 - 100,0) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,1 - 100,0) NTU"}],"search_en":"Water intended for human consumption Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09","technique_en":"Nephelometric method","test_object_en":"Water intended for human consumption","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,1 - 100,0) NTU"}],"search_zh":"生活饮用水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"生活饮用水"},{"_id":"6a836c58af14b9c0e7b1e381","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań fizycznych i chemicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań fizycznych i chemicznych","reference":"PN-ISO 5667-5:2017-10","norm_bases":["PN-ISO 5667-5:2017-10"],"lab_section":"Pracownia Analiz Fizyko-chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań fizycznych i chemicznych PN-ISO 5667-5:2017-10 Woda do spozycia przez ludzi Pobieranie probek do badan fizycznych i chemicznych PN-ISO 5667-5:2017-10","categories":["water"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for physical and chemical testing","search_en":"Water intended for human consumption Sampling for physical and chemical testing PN-ISO 5667-5:2017-10","test_object_en":"Water intended for human consumption","methodology_zh":"物理与化学检测用样品采集","search_zh":"生活饮用水 物理与化学检测用样品采集 PN-ISO 5667-5:2017-10","test_object_zh":"生活饮用水"},{"_id":"6a836c58af14b9c0e7b1e382","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Pasze","methodology":"Zawartość suchej masy lub wody","parameters":[{"name":"sucha masa","range":"(1,0 – 99,0)%"},{"name":"woda","range":"(1,0 – 99,0)%"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość suchej masy lub wody\nZakres:\nsucha masa (1,0 – 99,0)%\nwoda (1,0 – 99,0)%\nMetoda wagowa","reference":"Rozporządzenie Wykonawcze Komisji (UE) 2024/771 z dnia 29.02.2024 r. zał. III, A p. 4.2.1 i 4.2.2","norm_bases":["Rozporządzenie Wykonawcze Komisji (UE) 2024/771 z dnia 29.02.2024 r. zał. III, A p. 4.2.1 i 4.2.2"],"lab_section":"Pracownia Analiz Fizyko-chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pasze Zawartość suchej masy lub wody\nZakres:\nsucha masa (1,0 – 99,0)%\nwoda (1,0 – 99,0)%\nMetoda wagowa Rozporządzenie Wykonawcze Komisji (UE) 2024/771 z dnia 29.02.2024 r. zał. III, A p. 4.2.1 i 4.2.2 Pasze Zawartosc suchej masy lub wody\nZakres:\nsucha masa (1,0 – 99,0)%\nwoda (1,0 – 99,0)%\nMetoda wagowa Rozporzadzenie Wykonawcze Komisji (UE) 2024/771 z dnia 29.02.2024 r. zal. III, A p. 4.2.1 i 4.2.2","categories":["water","food"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry matter or water content","parameters_en":[{"name":"dry matter","range":"(1,0 – 99,0)%"},{"name":"water","range":"(1,0 – 99,0)%"}],"search_en":"Feed Dry matter or water content Gravimetric method dry matter water Rozporządzenie Wykonawcze Komisji (UE) 2024/771 z dnia 29.02.2024 r. zał. III, A p. 4.2.1 i 4.2.2","technique_en":"Gravimetric method","test_object_en":"Feed","search_zh":"饲料 重量法 干物质 水 Rozporządzenie Wykonawcze Komisji (UE) 2024/771 z dnia 29.02.2024 r. zał. III, A p. 4.2.1 i 4.2.2","technique_zh":"重量法","test_object_zh":"饲料","parameters_zh":[{"name":"干物质","range":"(1,0 – 99,0)%"},{"name":"水","range":"(1,0 – 99,0)%"}]},{"_id":"6a836c58af14b9c0e7b1e383","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Pasze","methodology":"Zawartość azotu","parameters":[{"name":"Zakres","range":"(0,06 - 15,00) %"},{"name":"Zawartość białka surowego (z obliczeń)"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu\nZakres:\nZakres (0,06 - 15,00) %\nZawartość białka surowego (z obliczeń)\nMetoda miareczkowa","reference":"Rozporządzenie Wykonawcze Komisji (UE) 2024/771 z dnia 29.02.2024 r. zał. III, C","norm_bases":["Rozporządzenie Wykonawcze Komisji (UE) 2024/771 z dnia 29.02.2024 r. zał. III, C"],"lab_section":"Pracownia Analiz Fizyko-chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pasze Zawartość azotu\nZakres:\nZakres (0,06 - 15,00) %\nZawartość białka surowego (z obliczeń)\nMetoda miareczkowa Rozporządzenie Wykonawcze Komisji (UE) 2024/771 z dnia 29.02.2024 r. zał. III, C Pasze Zawartosc azotu\nZakres:\nZakres (0,06 - 15,00) %\nZawartosc bialka surowego (z obliczen)\nMetoda miareczkowa Rozporzadzenie Wykonawcze Komisji (UE) 2024/771 z dnia 29.02.2024 r. zal. III, C","categories":["food"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrogen content","parameters_en":[{"name":"Range","range":"(0,06 - 15,00) %"},{"name":"Crude protein content (calculated)"}],"search_en":"Feed Nitrogen content Titrimetric method Range Crude protein content (calculated) Rozporządzenie Wykonawcze Komisji (UE) 2024/771 z dnia 29.02.2024 r. zał. III, C","technique_en":"Titrimetric method","test_object_en":"Feed","methodology_zh":"氮含量","parameters_zh":[{"name":"范围","range":"(0,06 - 15,00) %"},{"name":"粗蛋白含量（由计算得出）"}],"search_zh":"饲料 氮含量 滴定法 范围 粗蛋白含量（由计算得出） Rozporządzenie Wykonawcze Komisji (UE) 2024/771 z dnia 29.02.2024 r. zał. III, C","technique_zh":"滴定法","test_object_zh":"饲料"},{"_id":"6a836c58af14b9c0e7b1e384","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Pasze","methodology":"Zawartość tłuszczu surowego","parameters":[{"name":"Zakres","range":"(0,5 - 90,0) %"}],"technique":"Metoda ekstrakcyjno - wagowa","techniques":["Metoda ekstrakcyjno - wagowa"],"computed":[],"activity":"Zawartość tłuszczu surowego\nZakres (0,5 - 90,0) %\nMetoda ekstrakcyjno - wagowa","reference":"Rozporządzenie Wykonawcze Komisji (UE) 2024/771 z dnia 29.02.2024 r. zał. III, G p. 5.2","norm_bases":["Rozporządzenie Wykonawcze Komisji (UE) 2024/771 z dnia 29.02.2024 r. zał. III, G p. 5.2"],"lab_section":"Pracownia Analiz Fizyko-chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pasze Zawartość tłuszczu surowego\nZakres (0,5 - 90,0) %\nMetoda ekstrakcyjno - wagowa Rozporządzenie Wykonawcze Komisji (UE) 2024/771 z dnia 29.02.2024 r. zał. III, G p. 5.2 Pasze Zawartosc tluszczu surowego\nZakres (0,5 - 90,0) %\nMetoda ekstrakcyjno - wagowa Rozporzadzenie Wykonawcze Komisji (UE) 2024/771 z dnia 29.02.2024 r. zal. III, G p. 5.2","categories":["food"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Crude fat content","parameters_en":[{"name":"Range","range":"(0,5 - 90,0) %"}],"search_en":"Feed Crude fat content Extraction - gravimetric method Range Rozporządzenie Wykonawcze Komisji (UE) 2024/771 z dnia 29.02.2024 r. zał. III, G p. 5.2","technique_en":"Extraction - gravimetric method","test_object_en":"Feed","parameters_zh":[{"name":"范围","range":"(0,5 - 90,0) %"}],"search_zh":"饲料 粗脂肪含量 萃取-重量法 范围 Rozporządzenie Wykonawcze Komisji (UE) 2024/771 z dnia 29.02.2024 r. zał. III, G p. 5.2","test_object_zh":"饲料","methodology_zh":"粗脂肪含量","technique_zh":"萃取-重量法"},{"_id":"6a836c58af14b9c0e7b1e385","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Pasze","methodology":"Zawartość popiołu surowego","parameters":[{"name":"Zakres","range":"(0,10 - 80,00)%"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość popiołu surowego\nZakres (0,10 - 80,00)%\nMetoda wagowa","reference":"Rozporządzenie Wykonawcze Komisji (UE) 2024/771 z dnia 29.02.2024 r. zał. III, L","norm_bases":["Rozporządzenie Wykonawcze Komisji (UE) 2024/771 z dnia 29.02.2024 r. zał. III, L"],"lab_section":"Pracownia Analiz Fizyko-chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pasze Zawartość popiołu surowego\nZakres (0,10 - 80,00)%\nMetoda wagowa Rozporządzenie Wykonawcze Komisji (UE) 2024/771 z dnia 29.02.2024 r. zał. III, L Pasze Zawartosc popiolu surowego\nZakres (0,10 - 80,00)%\nMetoda wagowa Rozporzadzenie Wykonawcze Komisji (UE) 2024/771 z dnia 29.02.2024 r. zal. III, L","categories":["food"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Crude ash content","parameters_en":[{"name":"Range","range":"(0,10 - 80,00)%"}],"search_en":"Feed Crude ash content Gravimetric method Range Rozporządzenie Wykonawcze Komisji (UE) 2024/771 z dnia 29.02.2024 r. zał. III, L","technique_en":"Gravimetric method","test_object_en":"Feed","parameters_zh":[{"name":"范围","range":"(0,10 - 80,00)%"}],"search_zh":"饲料 粗灰分含量 重量法 范围 Rozporządzenie Wykonawcze Komisji (UE) 2024/771 z dnia 29.02.2024 r. zał. III, L","technique_zh":"重量法","test_object_zh":"饲料","methodology_zh":"粗灰分含量"},{"_id":"6a836c58af14b9c0e7b1e386","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Pasze","methodology":"Zawartość popiołu nierozpuszczalnego w 10% HCl","parameters":[{"name":"Zakres","range":"(0,02 - 5,00) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość popiołu nierozpuszczalnego w 10% HCl\nZakres (0,02 - 5,00) %\nMetoda wagowa","reference":"Rozporządzenie Wykonawcze Komisji (UE) 2024/771 z dnia 29.02.2024 r. zał. III, M, metoda A","norm_bases":["Rozporządzenie Wykonawcze Komisji (UE) 2024/771 z dnia 29.02.2024 r. zał. III, M, metoda A"],"lab_section":"Pracownia Analiz Fizyko-chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pasze Zawartość popiołu nierozpuszczalnego w 10% HCl\nZakres (0,02 - 5,00) %\nMetoda wagowa Rozporządzenie Wykonawcze Komisji (UE) 2024/771 z dnia 29.02.2024 r. zał. III, M, metoda A Pasze Zawartosc popiolu nierozpuszczalnego w 10% HCl\nZakres (0,02 - 5,00) %\nMetoda wagowa Rozporzadzenie Wykonawcze Komisji (UE) 2024/771 z dnia 29.02.2024 r. zal. III, M, metoda A","categories":["food"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of ash insoluble in 10% HCl","parameters_en":[{"name":"Range","range":"(0,02 - 5,00) %"}],"search_en":"Feed Content of ash insoluble in 10% HCl Gravimetric method Range Rozporządzenie Wykonawcze Komisji (UE) 2024/771 z dnia 29.02.2024 r. zał. III, M, metoda A","technique_en":"Gravimetric method","test_object_en":"Feed","parameters_zh":[{"name":"范围","range":"(0,02 - 5,00) %"}],"search_zh":"饲料 重量法 范围 Rozporządzenie Wykonawcze Komisji (UE) 2024/771 z dnia 29.02.2024 r. zał. III, M, metoda A","technique_zh":"重量法","test_object_zh":"饲料"},{"_id":"6a836c58af14b9c0e7b1e387","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Pasze","methodology":"Zawartość włókna surowego","parameters":[{"name":"Zakres","range":"(0,1 – 30,0)%"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość włókna surowego\nZakres (0,1 – 30,0)%\nMetoda wagowa","reference":"Rozporządzenie Wykonawcze Komisji (UE) 2024/771 z dnia 29.02.2024 r. zał. III, H","norm_bases":["Rozporządzenie Wykonawcze Komisji (UE) 2024/771 z dnia 29.02.2024 r. zał. III, H"],"lab_section":"Pracownia Analiz Fizyko-chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pasze Zawartość włókna surowego\nZakres (0,1 – 30,0)%\nMetoda wagowa Rozporządzenie Wykonawcze Komisji (UE) 2024/771 z dnia 29.02.2024 r. zał. III, H Pasze Zawartosc wlokna surowego\nZakres (0,1 – 30,0)%\nMetoda wagowa Rozporzadzenie Wykonawcze Komisji (UE) 2024/771 z dnia 29.02.2024 r. zal. III, H","categories":["food"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Crude fibre content","parameters_en":[{"name":"Range","range":"(0,1 – 30,0)%"}],"search_en":"Feed Crude fibre content Gravimetric method Range Rozporządzenie Wykonawcze Komisji (UE) 2024/771 z dnia 29.02.2024 r. zał. III, H","technique_en":"Gravimetric method","test_object_en":"Feed","parameters_zh":[{"name":"范围","range":"(0,1 – 30,0)%"}],"search_zh":"饲料 粗纤维含量 重量法 范围 Rozporządzenie Wykonawcze Komisji (UE) 2024/771 z dnia 29.02.2024 r. zał. III, H","technique_zh":"重量法","test_object_zh":"饲料","methodology_zh":"粗纤维含量"},{"_id":"6a836c58af14b9c0e7b1e388","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Pasze","methodology":"Zawartość skrobi","parameters":[{"name":"Zakres","range":"(1,0 -70,0)%"}],"technique":"Metoda polarymetryczna","techniques":["Metoda polarymetryczna"],"computed":[],"activity":"Zawartość skrobi\nZakres (1,0 -70,0)%\nMetoda polarymetryczna","reference":"Rozporządzenie Wykonawcze Komisji (UE) 2024/771 z dnia 29.02.2024 r. zał. III, K","norm_bases":["Rozporządzenie Wykonawcze Komisji (UE) 2024/771 z dnia 29.02.2024 r. zał. III, K"],"lab_section":"Pracownia Analiz Fizyko-chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pasze Zawartość skrobi\nZakres (1,0 -70,0)%\nMetoda polarymetryczna Rozporządzenie Wykonawcze Komisji (UE) 2024/771 z dnia 29.02.2024 r. zał. III, K Pasze Zawartosc skrobi\nZakres (1,0 -70,0)%\nMetoda polarymetryczna Rozporzadzenie Wykonawcze Komisji (UE) 2024/771 z dnia 29.02.2024 r. zal. III, K","categories":["food"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Starch content","parameters_en":[{"name":"Range","range":"(1,0 -70,0)%"}],"search_en":"Feed Starch content Polarimetric method Range Rozporządzenie Wykonawcze Komisji (UE) 2024/771 z dnia 29.02.2024 r. zał. III, K","technique_en":"Polarimetric method","test_object_en":"Feed","parameters_zh":[{"name":"范围","range":"(1,0 -70,0)%"}],"search_zh":"饲料 淀粉含量 旋光法 范围 Rozporządzenie Wykonawcze Komisji (UE) 2024/771 z dnia 29.02.2024 r. zał. III, K","test_object_zh":"饲料","methodology_zh":"淀粉含量","technique_zh":"旋光法"},{"_id":"6a836c58af14b9c0e7b1e389","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Pasze","methodology":"pH","parameters":[{"name":"Zakres","range":"2,00 – 8,00"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,00 – 8,00\nMetoda potencjometryczna","reference":"MP-03208-PL wersja 2 ważna od 12.02.2025","norm_bases":["MP-03208-PL wersja 2 ważna od 12.02.2025"],"lab_section":"Pracownia Analiz Fizyko-chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pasze pH\nZakres 2,00 – 8,00\nMetoda potencjometryczna MP-03208-PL wersja 2 ważna od 12.02.2025 Pasze pH\nZakres 2,00 – 8,00\nMetoda potencjometryczna MP-03208-PL wersja 2 wazna od 12.02.2025","categories":["food"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,00 – 8,00"}],"search_en":"Feed pH Potentiometric method Range MP-03208-PL wersja 2 ważna od 12.02.2025","technique_en":"Potentiometric method","test_object_en":"Feed","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,00 – 8,00"}],"search_zh":"饲料 pH 值 电位法 范围 MP-03208-PL wersja 2 ważna od 12.02.2025","technique_zh":"电位法","test_object_zh":"饲料"},{"_id":"6a836c58af14b9c0e7b1e38a","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Karmy dla zwierząt","methodology":"Wygląd, Barwa, Konsystencja, Zapach","parameters":[],"technique":"Prosty test opisowy","techniques":["Prosty test opisowy"],"computed":[],"activity":"Wygląd, Barwa, Konsystencja, Zapach\nProsty test opisowy","reference":"MP-03700-PL wersja 1 ważna od 17.01.2025","norm_bases":["MP-03700-PL wersja 1 ważna od 17.01.2025"],"lab_section":"Pracownia Analiz Fizyko-chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Karmy dla zwierząt Wygląd, Barwa, Konsystencja, Zapach\nProsty test opisowy MP-03700-PL wersja 1 ważna od 17.01.2025 Karmy dla zwierzat Wyglad, Barwa, Konsystencja, Zapach\nProsty test opisowy MP-03700-PL wersja 1 wazna od 17.01.2025","categories":["food"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Appearance, Colour, Consistency, Odour","search_en":"Animal feeds Appearance, Colour, Consistency, Odour Simple descriptive test MP-03700-PL wersja 1 ważna od 17.01.2025","technique_en":"Simple descriptive test","test_object_en":"Animal feeds"},{"_id":"6a836c58af14b9c0e7b1e38b","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość azotu","parameters":[{"name":"Zawartość białka (z obliczeń)"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu\nZawartość białka (z obliczeń)\nMetoda miareczkowa","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Analiz Fizyko-chemicznych","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Żywność E Zawartość azotu\nZawartość białka (z obliczeń)\nMetoda miareczkowa Procedury badawcze Zywnosc E Zawartosc azotu\nZawartosc bialka (z obliczen)\nMetoda miareczkowa Procedury badawcze","categories":["food"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrogen content","parameters_en":[{"name":"Protein content (calculated)"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Food E Nitrogen content Titrimetric method E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Protein content (calculated) Procedury badawcze","technique_en":"Titrimetric method","test_object_en":"Food E","methodology_zh":"氮含量","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"食品 E 氮含量 滴定法 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 蛋白质含量（计算值） Procedury badawcze","technique_zh":"滴定法","test_object_zh":"食品 E","parameters_zh":[{"name":"蛋白质含量（计算值）"}]},{"_id":"6a836c58af14b9c0e7b1e38c","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość błonnika","parameters":[],"technique":"Metoda enzymatyczno - wagowa","techniques":["Metoda enzymatyczno - wagowa"],"computed":[],"activity":"Zawartość błonnika\nMetoda enzymatyczno - wagowa","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Analiz Fizyko-chemicznych","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Żywność E Zawartość błonnika\nMetoda enzymatyczno - wagowa Procedury badawcze Zywnosc E Zawartosc blonnika\nMetoda enzymatyczno - wagowa Procedury badawcze","categories":["food"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fibre content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Food E Fibre content Enzymatic - gravimetric method E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Procedury badawcze","technique_en":"Enzymatic - gravimetric method","test_object_en":"Food E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"食品 E E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 Procedury badawcze","test_object_zh":"食品 E"},{"_id":"6a836c58af14b9c0e7b1e38d","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość tłuszczu","parameters":[],"technique":"Metoda ekstrakcyjno - wagowa","techniques":["Metoda ekstrakcyjno - wagowa"],"computed":[],"activity":"Zawartość tłuszczu\nMetoda ekstrakcyjno - wagowa","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Analiz Fizyko-chemicznych","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Żywność E Zawartość tłuszczu\nMetoda ekstrakcyjno - wagowa Procedury badawcze Zywnosc E Zawartosc tluszczu\nMetoda ekstrakcyjno - wagowa Procedury badawcze","categories":["food"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fat content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Food E Fat content Extraction - gravimetric method E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Procedury badawcze","technique_en":"Extraction - gravimetric method","test_object_en":"Food E","methodology_zh":"脂肪含量","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"食品 E 脂肪含量 萃取-重量法 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 Procedury badawcze","test_object_zh":"食品 E","technique_zh":"萃取-重量法"},{"_id":"6a836c58af14b9c0e7b1e38e","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość suchej masy lub wody","parameters":[],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość suchej masy lub wody\nMetoda wagowa","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Analiz Fizyko-chemicznych","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Żywność E Zawartość suchej masy lub wody\nMetoda wagowa Procedury badawcze Zywnosc E Zawartosc suchej masy lub wody\nMetoda wagowa Procedury badawcze","categories":["water","food"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry matter or water content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Food E Dry matter or water content Gravimetric method E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Procedury badawcze","technique_en":"Gravimetric method","test_object_en":"Food E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"食品 E 重量法 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 Procedury badawcze","technique_zh":"重量法","test_object_zh":"食品 E"},{"_id":"6a836c58af14b9c0e7b1e38f","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość popiołu ogółem","parameters":[],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość popiołu ogółem\nMetoda wagowa","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Analiz Fizyko-chemicznych","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Żywność E Zawartość popiołu ogółem\nMetoda wagowa Procedury badawcze Zywnosc E Zawartosc popiolu ogolem\nMetoda wagowa Procedury badawcze","categories":["food"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Overall ash content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Food E Overall ash content Gravimetric method E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Procedury badawcze","technique_en":"Gravimetric method","test_object_en":"Food E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"食品 E 重量法 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 Procedury badawcze","technique_zh":"重量法","test_object_zh":"食品 E"},{"_id":"6a836c58af14b9c0e7b1e390","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość popiołu nierozpuszczalnego w 10% HCl","parameters":[],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość popiołu nierozpuszczalnego w 10% HCl\nMetoda wagowa","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Analiz Fizyko-chemicznych","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Żywność E Zawartość popiołu nierozpuszczalnego w 10% HCl\nMetoda wagowa Procedury badawcze Zywnosc E Zawartosc popiolu nierozpuszczalnego w 10% HCl\nMetoda wagowa Procedury badawcze","categories":["food"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of ash insoluble in 10% HCl","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Food E Content of ash insoluble in 10% HCl Gravimetric method E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Procedury badawcze","technique_en":"Gravimetric method","test_object_en":"Food E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"食品 E 重量法 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 Procedury badawcze","technique_zh":"重量法","test_object_zh":"食品 E"},{"_id":"6a836c58af14b9c0e7b1e391","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Żywność E","methodology":"Węglowodany ogółem (%), Węglowodany przyswajalne (%), Wartość energetyczna (kJ/100g), Wartość kaloryczna (kcal/100g) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Węglowodany ogółem (%), Węglowodany przyswajalne (%), Wartość energetyczna (kJ/100g), Wartość kaloryczna (kcal/100g) (z obliczeń)","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Analiz Fizyko-chemicznych","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Żywność E Węglowodany ogółem (%), Węglowodany przyswajalne (%), Wartość energetyczna (kJ/100g), Wartość kaloryczna (kcal/100g) (z obliczeń) Procedury badawcze Zywnosc E Weglowodany ogolem (%), Weglowodany przyswajalne (%), Wartosc energetyczna (kJ/100g), Wartosc kaloryczna (kcal/100g) (z obliczen) Procedury badawcze","categories":["food"],"row_index":55,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total carbohydrates (%), Available carbohydrates (%), Energy value (kJ/100g), Caloric value (kcal/100g) (calculated)","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Food E Total carbohydrates (%), Available carbohydrates (%), Energy value (kJ/100g), Caloric value (kcal/100g) (calculated) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Procedury badawcze","test_object_en":"Food E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"食品 E E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 Procedury badawcze","test_object_zh":"食品 E"},{"_id":"6a836c58af14b9c0e7b1e392","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość soli kuchennej (NaCl)","parameters":[],"technique":"Metoda miareczkowania potencjometrycznego","techniques":["Metoda miareczkowania potencjometrycznego"],"computed":[],"activity":"Zawartość soli kuchennej (NaCl)\nMetoda miareczkowania potencjometrycznego","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Analiz Fizyko-chemicznych","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Żywność E Zawartość soli kuchennej (NaCl)\nMetoda miareczkowania potencjometrycznego Procedury badawcze Zywnosc E Zawartosc soli kuchennej (NaCl)\nMetoda miareczkowania potencjometrycznego Procedury badawcze","categories":["food"],"row_index":56,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Table salt content (NaCl)","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Food E Table salt content (NaCl) Potentiometric titration method E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Procedury badawcze","technique_en":"Potentiometric titration method","test_object_en":"Food E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"食品 E 电位滴定法 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 Procedury badawcze","technique_zh":"电位滴定法","test_object_zh":"食品 E"},{"_id":"6a836c58af14b9c0e7b1e393","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Żywność E","methodology":"Kwasowość","parameters":[],"technique":"Metoda miareczkowania potencjometrycznego","techniques":["Metoda miareczkowania potencjometrycznego"],"computed":[],"activity":"Kwasowość\nMetoda miareczkowania potencjometrycznego","reference":"Normy | Procedury badawcze","norm_bases":["Normy","Procedury badawcze"],"lab_section":"Pracownia Analiz Fizyko-chemicznych","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Żywność E Kwasowość\nMetoda miareczkowania potencjometrycznego Normy | Procedury badawcze Zywnosc E Kwasowosc\nMetoda miareczkowania potencjometrycznego Normy | Procedury badawcze","categories":["food"],"row_index":57,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Acidity","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Food E Acidity Potentiometric titration method E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Normy | Procedury badawcze","technique_en":"Potentiometric titration method","test_object_en":"Food E","methodology_zh":"酸度","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"食品 E 酸度 电位滴定法 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 Normy | Procedury badawcze","technique_zh":"电位滴定法","test_object_zh":"食品 E"},{"_id":"6a836c58af14b9c0e7b1e394","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Żywność E","methodology":"Objętość","parameters":[],"technique":"Metoda bezpośredniego pomiaru objętości","techniques":["Metoda bezpośredniego pomiaru objętości"],"computed":[],"activity":"Objętość\nMetoda bezpośredniego pomiaru objętości","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Analiz Fizyko-chemicznych","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Żywność E Objętość\nMetoda bezpośredniego pomiaru objętości Procedury badawcze Zywnosc E Objetosc\nMetoda bezposredniego pomiaru objetosci Procedury badawcze","categories":["food"],"row_index":58,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Volume","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Food E Volume Direct volume measurement method E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Procedury badawcze","technique_en":"Direct volume measurement method","test_object_en":"Food E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"食品 E 体积 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 Procedury badawcze","test_object_zh":"食品 E","methodology_zh":"体积"},{"_id":"6a836c58af14b9c0e7b1e395","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Żywność E","methodology":"Objętość (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Objętość (z obliczeń)","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Analiz Fizyko-chemicznych","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Żywność E Objętość (z obliczeń) Procedury badawcze Zywnosc E Objetosc (z obliczen) Procedury badawcze","categories":["food"],"row_index":59,"parse_version":4,"parse_source":"agent-claude-code","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Food E E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Procedury badawcze","test_object_en":"Food E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"食品 E E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 Procedury badawcze","test_object_zh":"食品 E"},{"_id":"6a836c58af14b9c0e7b1e396","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Żywność E, Kosmetyki E, Wyroby chemiczne E","methodology":"Gęstość","parameters":[],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"computed":[],"activity":"Gęstość\nMetoda oscylacyjna","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Analiz Fizyko-chemicznych","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Żywność E, Kosmetyki E, Wyroby chemiczne E Gęstość\nMetoda oscylacyjna Procedury badawcze Zywnosc E, Kosmetyki E, Wyroby chemiczne E Gestosc\nMetoda oscylacyjna Procedury badawcze","categories":["food","pharma"],"row_index":60,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Density","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Density Oscillation method E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Procedury badawcze","technique_en":"Oscillation method","methodology_zh":"密度","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"密度 振荡法 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 Procedury badawcze","technique_zh":"振荡法"},{"_id":"6a836c58af14b9c0e7b1e397","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Żywność E, Pasze E","methodology":"Aktywność wody","parameters":[],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Aktywność wody\nMetoda elektrochemiczna","reference":"PN-ISO 21807","norm_bases":["PN-ISO 21807"],"lab_section":"Pracownia Analiz Fizyko-chemicznych","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Żywność E, Pasze E Aktywność wody\nMetoda elektrochemiczna PN-ISO 21807 Zywnosc E, Pasze E Aktywnosc wody\nMetoda elektrochemiczna PN-ISO 21807","categories":["food","water"],"row_index":61,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water activity","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Food E, Feed E Water activity Electrochemical method E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-ISO 21807","technique_en":"Electrochemical method","test_object_en":"Food E, Feed E","methodology_zh":"水分活度","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"食品 E、饲料 E 水分活度 电化学法 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-ISO 21807","technique_zh":"电化学法","test_object_zh":"食品 E、饲料 E"},{"_id":"6a836c58af14b9c0e7b1e398","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Towary paczkowane E","methodology":"Masa netto","parameters":[],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Masa netto\nMetoda wagowa","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Analiz Fizyko-chemicznych","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Towary paczkowane E Masa netto\nMetoda wagowa Procedury badawcze Towary paczkowane E Masa netto\nMetoda wagowa Procedury badawcze","categories":["other"],"row_index":62,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Net weight","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Net weight Gravimetric method E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Procedury badawcze","technique_en":"Gravimetric method","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"净重 重量法 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 Procedury badawcze","technique_zh":"重量法","methodology_zh":"净重"},{"_id":"6a836c58af14b9c0e7b1e399","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Przyprawy i zioła E","methodology":"Zawartość olejków eterycznych","parameters":[],"technique":"Metoda pomiaru objętości","techniques":["Metoda pomiaru objętości"],"computed":[],"activity":"Zawartość olejków eterycznych\nMetoda pomiaru objętości","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Analiz Fizyko-chemicznych","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Przyprawy i zioła E Zawartość olejków eterycznych\nMetoda pomiaru objętości Procedury badawcze Przyprawy i ziola E Zawartosc olejkow eterycznych\nMetoda pomiaru objetosci Procedury badawcze","categories":["petro"],"row_index":63,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Essential oil content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Essential oil content Volume measurement method E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Procedury badawcze","technique_en":"Volume measurement method","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 Procedury badawcze"},{"_id":"6a836c58af14b9c0e7b1e39a","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Suszone zioła, Ryby i przetwory rybne, Mięso i przetwory mięsne, Herbaty, Kawy, Przyprawy, Wyroby czekoladowe i kakaowe, Wyroby cukiernicze, Słone przekąski, Oleje i tłuszcze, Wyroby garmażeryjne, Nasiona roślin oleistych","methodology":"Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA)","parameters":[{"name":"Benzo(a)piren","range":"(1,0-100,0)µg/kg"},{"name":"Benz(a)antracen","range":"(1,0-100,0)µg/kg"},{"name":"Benzo(b) fluoranten","range":"(1,0-100,0)µg/kg"},{"name":"Chryzen","range":"(1,0-100,0)µg/kg"},{"name":"Suma WWA (z obliczeń)"}],"technique":"Metoda chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA)\nZakres:\nBenzo(a)piren (1,0-100,0)µg/kg\nBenz(a)antracen (1,0-100,0)µg/kg\nBenzo(b) fluoranten (1,0-100,0)µg/kg\nChryzen (1,0-100,0)µg/kg\nSuma WWA (z obliczeń)\nMetoda chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"MP-03910-PL wersja 1 ważna od 11.02.2026","norm_bases":["MP-03910-PL wersja 1 ważna od 11.02.2026"],"lab_section":"Pracownia Analiz Instrumentalnych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Suszone zioła, Ryby i przetwory rybne, Mięso i przetwory mięsne, Herbaty, Kawy, Przyprawy, Wyroby czekoladowe i kakaowe, Wyroby cukiernicze, Słone przekąski, Oleje i tłuszcze, Wyroby garmażeryjne, Nasiona roślin oleistych Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA)\nZakres:\nBenzo(a)piren (1,0-100,0)µg/kg\nBenz(a)antracen (1,0-100,0)µg/kg\nBenzo(b) fluoranten (1,0-100,0)µg/kg\nChryzen (1,0-100,0)µg/kg\nSuma WWA (z obliczeń)\nMetoda chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) MP-03910-PL wersja 1 ważna od 11.02.2026 Suszone ziola, Ryby i przetwory rybne, Mieso i przetwory miesne, Herbaty, Kawy, Przyprawy, Wyroby czekoladowe i kakaowe, Wyroby cukiernicze, Slone przekaski, Oleje i tluszcze, Wyroby garmazeryjne, Nasiona roslin oleistych Zawartosc wielopierscieniowych weglowodorow aromatycznych (WWA)\nZakres:\nBenzo(a)piren (1,0-100,0)µg/kg\nBenz(a)antracen (1,0-100,0)µg/kg\nBenzo(b) fluoranten (1,0-100,0)µg/kg\nChryzen (1,0-100,0)µg/kg\nSuma WWA (z obliczen)\nMetoda chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) MP-03910-PL wersja 1 wazna od 11.02.2026","categories":["food","petro"],"row_index":64,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Instrumental Analysis Laboratory","methodology_en":"Polycyclic aromatic hydrocarbons (PAH) content","parameters_en":[{"name":"Benzo(a)pyrene","range":"(1,0-100,0)µg/kg"},{"name":"Benz(a)anthracene","range":"(1,0-100,0)µg/kg"},{"name":"Benzo(b) fluoranten","range":"(1,0-100,0)µg/kg"},{"name":"Chrysene","range":"(1,0-100,0)µg/kg"},{"name":"Sum of PAH (calculated)"}],"search_en":"Polycyclic aromatic hydrocarbons (PAH) content Liquid chromatography with fluorescence detection (HPLC-FLD) Instrumental Analysis Laboratory Benzo(a)pyrene Benz(a)anthracene Chrysene Sum of PAH (calculated) MP-03910-PL wersja 1 ważna od 11.02.2026","technique_en":"Liquid chromatography with fluorescence detection (HPLC-FLD)","methodology_zh":"多环芳烃（PAHs）含量","search_zh":"多环芳烃（PAHs）含量 液相色谱-荧光检测法（HPLC-FLD） 仪器分析检验室 苯并(a)芘 䓛 多环芳烃总量（计算值） MP-03910-PL wersja 1 ważna od 11.02.2026","parameters_zh":[{"name":"苯并(a)芘","range":"(1,0-100,0)µg/kg"},{"name":"Benz(a)antracen","range":"(1,0-100,0)µg/kg"},{"name":"Benzo(b) fluoranten","range":"(1,0-100,0)µg/kg"},{"name":"䓛","range":"(1,0-100,0)µg/kg"},{"name":"多环芳烃总量（计算值）"}],"lab_section_zh":"仪器分析检验室","technique_zh":"液相色谱-荧光检测法（HPLC-FLD）"},{"_id":"6a836c58af14b9c0e7b1e39b","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Owoce i warzywa, Zboża i produkty zbożowe","methodology":"Zawartość jonu bromkowego","parameters":[{"name":"Jon bromkowy","range":"(1,0 – 100) mg/kg"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Zawartość jonu bromkowego\nJon bromkowy (1,0 – 100) mg/kg\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"MP-03909-PL wersja 1 ważna od 11.02.2026","norm_bases":["MP-03909-PL wersja 1 ważna od 11.02.2026"],"lab_section":"Pracownia Analiz Instrumentalnych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Owoce i warzywa, Zboża i produkty zbożowe Zawartość jonu bromkowego\nJon bromkowy (1,0 – 100) mg/kg\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) MP-03909-PL wersja 1 ważna od 11.02.2026 Owoce i warzywa, Zboza i produkty zbozowe Zawartosc jonu bromkowego\nJon bromkowy (1,0 – 100) mg/kg\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) MP-03909-PL wersja 1 wazna od 11.02.2026","categories":["other"],"row_index":65,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Instrumental Analysis Laboratory","methodology_en":"Bromide ion content","search_en":"Bromide ion content Ion chromatography with conductometric detection (IC-CD) Instrumental Analysis Laboratory MP-03909-PL wersja 1 ważna od 11.02.2026","technique_en":"Ion chromatography with conductometric detection (IC-CD)","search_zh":"离子色谱-电导检测法（IC-CD） 仪器分析检验室 MP-03909-PL wersja 1 ważna od 11.02.2026","technique_zh":"离子色谱-电导检测法（IC-CD）","lab_section_zh":"仪器分析检验室"},{"_id":"6a836c58af14b9c0e7b1e39c","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Żywność E, Pasze E, Produkty rolne E","methodology":"Zawartość pozostałości pestycydów","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC- MS-MS)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC- MS-MS)"],"computed":[],"activity":"Zawartość pozostałości pestycydów\nMetoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC- MS-MS)","reference":"PN-EN 15662 | Procedury badawcze","norm_bases":["PN-EN 15662","Procedury badawcze"],"lab_section":"Pracownia Analiz Instrumentalnych","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Żywność E, Pasze E, Produkty rolne E Zawartość pozostałości pestycydów\nMetoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC- MS-MS) PN-EN 15662 | Procedury badawcze Zywnosc E, Pasze E, Produkty rolne E Zawartosc pozostalosci pestycydow\nMetoda wysokosprawnej chromatografii cieczowej z detekcja tandemowa spektrometria mas (LC- MS-MS) PN-EN 15662 | Procedury badawcze","categories":["food"],"row_index":66,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Instrumental Analysis Laboratory","methodology_en":"Pesticide residue content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Pesticide residue content High-performance liquid chromatography with tandem mass spectrometry detection (LC- MS-MS) Instrumental Analysis Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 15662 | Procedury badawcze","technique_en":"High-performance liquid chromatography with tandem mass spectrometry detection (LC- MS-MS)","methodology_zh":"农药残留含量","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"农药残留含量 仪器分析检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 15662 | Procedury badawcze","lab_section_zh":"仪器分析检验室"},{"_id":"6a836c58af14b9c0e7b1e39d","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Żywność E, Pasze E, Produkty rolne E","methodology":"Zawartość pozostałości pestycydów","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC- MS/MS)","techniques":["Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC- MS/MS)"],"computed":[],"activity":"Zawartość pozostałości pestycydów\nMetoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC- MS/MS)","reference":"PN-EN 15662","norm_bases":["PN-EN 15662"],"lab_section":"Pracownia Analiz Instrumentalnych","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Żywność E, Pasze E, Produkty rolne E Zawartość pozostałości pestycydów\nMetoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC- MS/MS) PN-EN 15662 Zywnosc E, Pasze E, Produkty rolne E Zawartosc pozostalosci pestycydow\nMetoda chromatografii gazowej z detekcja tandemowa spektrometria mas (GC- MS/MS) PN-EN 15662","categories":["food"],"row_index":67,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Instrumental Analysis Laboratory","methodology_en":"Pesticide residue content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Pesticide residue content Gas chromatography with tandem mass spectrometry detection (GC- MS/MS) Instrumental Analysis Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 15662","technique_en":"Gas chromatography with tandem mass spectrometry detection (GC- MS/MS)","methodology_zh":"农药残留含量","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"农药残留含量 仪器分析检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 15662","lab_section_zh":"仪器分析检验室"},{"_id":"6a836c58af14b9c0e7b1e39e","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Żywność E, Pasze E","methodology":"Zawartość pierwiastków","parameters":[],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"computed":[],"activity":"Zawartość pierwiastków\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"PN-EN 15763 | Procedury badawcze","norm_bases":["PN-EN 15763","Procedury badawcze"],"lab_section":"Pracownia Analiz Instrumentalnych","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Żywność E, Pasze E Zawartość pierwiastków\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) PN-EN 15763 | Procedury badawcze Zywnosc E, Pasze E Zawartosc pierwiastkow\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) PN-EN 15763 | Procedury badawcze","categories":["food"],"row_index":68,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Instrumental Analysis Laboratory","methodology_en":"Element content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Food E, Feed E Element content Inductively coupled plasma mass spectrometry (ICP-MS) Instrumental Analysis Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 15763 | Procedury badawcze","technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","test_object_en":"Food E, Feed E","methodology_zh":"元素含量","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"食品 E、饲料 E 元素含量 电感耦合等离子体质谱法（ICP-MS） 仪器分析检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 15763 | Procedury badawcze","technique_zh":"电感耦合等离子体质谱法（ICP-MS）","lab_section_zh":"仪器分析检验室","test_object_zh":"食品 E、饲料 E"},{"_id":"6a836c58af14b9c0e7b1e39f","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Żywność E, Pasze E","methodology":"Zawartość mykotoksyn","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)"],"computed":[],"activity":"Zawartość mykotoksyn\nMetoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Analiz Instrumentalnych","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Żywność E, Pasze E Zawartość mykotoksyn\nMetoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS) Procedury badawcze Zywnosc E, Pasze E Zawartosc mykotoksyn\nMetoda wysokosprawnej chromatografii cieczowej z detekcja tandemowa spektrometria mas (LC-MS-MS) Procedury badawcze","categories":["food"],"row_index":69,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Instrumental Analysis Laboratory","methodology_en":"Mycotoxin content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Food E, Feed E Mycotoxin content High-performance liquid chromatography with tandem mass spectrometry detection (LC-MS-MS) Instrumental Analysis Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Procedury badawcze","technique_en":"High-performance liquid chromatography with tandem mass spectrometry detection (LC-MS-MS)","test_object_en":"Food E, Feed E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"食品 E、饲料 E 霉菌毒素含量 高效液相色谱-串联质谱法（LC-MS-MS） 仪器分析检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 Procedury badawcze","methodology_zh":"霉菌毒素含量","lab_section_zh":"仪器分析检验室","technique_zh":"高效液相色谱-串联质谱法（LC-MS-MS）","test_object_zh":"食品 E、饲料 E"},{"_id":"6a836c58af14b9c0e7b1e3a0","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Żywność E, Pasze E","methodology":"Zawartość pierwiastków","parameters":[{"name":"Równoważnik soli w g/100g (z obliczeń)"},{"name":"Zawartość fosforu ogółem jako P2O5 (%), (g/kg) (z obliczeń)"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość pierwiastków\nZakres:\nRównoważnik soli w g/100g (z obliczeń)\nZawartość fosforu ogółem jako P2O5 (%), (g/kg) (z obliczeń)\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Analiz Instrumentalnych","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Żywność E, Pasze E Zawartość pierwiastków\nZakres:\nRównoważnik soli w g/100g (z obliczeń)\nZawartość fosforu ogółem jako P2O5 (%), (g/kg) (z obliczeń)\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) Procedury badawcze Zywnosc E, Pasze E Zawartosc pierwiastkow\nZakres:\nRownowaznik soli w g/100g (z obliczen)\nZawartosc fosforu ogolem jako P2O5 (%), (g/kg) (z obliczen)\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) Procedury badawcze","categories":["food"],"row_index":70,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Instrumental Analysis Laboratory","methodology_en":"Element content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Food E, Feed E Element content Inductively coupled plasma optical emission spectrometry (ICP-OES) Instrumental Analysis Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Procedury badawcze","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Food E, Feed E","methodology_zh":"元素含量","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"食品 E、饲料 E 元素含量 电感耦合等离子体原子发射光谱法（ICP-OES） 仪器分析检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 Procedury badawcze","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","lab_section_zh":"仪器分析检验室","test_object_zh":"食品 E、饲料 E"},{"_id":"6a836c58af14b9c0e7b1e3a1","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Żywność E, Pasze E","methodology":"Zawartość rtęci","parameters":[],"technique":"Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","techniques":["Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji"],"computed":[],"activity":"Zawartość rtęci\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Analiz Instrumentalnych","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Żywność E, Pasze E Zawartość rtęci\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji Procedury badawcze Zywnosc E, Pasze E Zawartosc rteci\nMetoda absorpcyjnej spektrometrii atomowej z technika amalgamacji Procedury badawcze","categories":["food"],"row_index":71,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Instrumental Analysis Laboratory","methodology_en":"Mercury content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Food E, Feed E Mercury content Atomic absorption spectrometry with amalgamation technique Instrumental Analysis Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Procedury badawcze","technique_en":"Atomic absorption spectrometry with amalgamation technique","test_object_en":"Food E, Feed E","methodology_zh":"汞含量","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"食品 E、饲料 E 汞含量 原子吸收光谱法（汞齐化技术） 仪器分析检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 Procedury badawcze","technique_zh":"原子吸收光谱法（汞齐化技术）","lab_section_zh":"仪器分析检验室","test_object_zh":"食品 E、饲料 E"},{"_id":"6a836c58af14b9c0e7b1e3a2","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość substancji konserwujących","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV/VIS)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV/VIS)"],"computed":[],"activity":"Zawartość substancji konserwujących\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV/VIS)","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Analiz Instrumentalnych","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Żywność E Zawartość substancji konserwujących\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV/VIS) Procedury badawcze Zywnosc E Zawartosc substancji konserwujacych\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC-UV/VIS) Procedury badawcze","categories":["food"],"row_index":72,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Instrumental Analysis Laboratory","methodology_en":"Preservative content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Food E Preservative content High-performance liquid chromatography with spectrophotometric detection (HPLC-UV/VIS) Instrumental Analysis Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Procedury badawcze","technique_en":"High-performance liquid chromatography with spectrophotometric detection (HPLC-UV/VIS)","test_object_en":"Food E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"食品 E 防腐剂含量 高效液相色谱-分光光度检测法（HPLC-UV/VIS） 仪器分析检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 Procedury badawcze","test_object_zh":"食品 E","technique_zh":"高效液相色谱-分光光度检测法（HPLC-UV/VIS）","lab_section_zh":"仪器分析检验室","methodology_zh":"防腐剂含量"},{"_id":"6a836c58af14b9c0e7b1e3a3","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość cukrów","parameters":[],"technique":"Metoda chromatografii cieczowej z detektorem laserowym światła rozproszonego (HPLC-ELSD)","techniques":["Metoda chromatografii cieczowej z detektorem laserowym światła rozproszonego (HPLC-ELSD)"],"computed":[],"activity":"Zawartość cukrów\nMetoda chromatografii cieczowej z detektorem laserowym światła rozproszonego (HPLC-ELSD)","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Analiz Instrumentalnych","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Żywność E Zawartość cukrów\nMetoda chromatografii cieczowej z detektorem laserowym światła rozproszonego (HPLC-ELSD) Procedury badawcze Zywnosc E Zawartosc cukrow\nMetoda chromatografii cieczowej z detektorem laserowym swiatla rozproszonego (HPLC-ELSD) Procedury badawcze","categories":["food"],"row_index":73,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Instrumental Analysis Laboratory","methodology_en":"Sugar content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Food E Sugar content Liquid chromatography with a laser light scattering detector (HPLC-ELSD) Instrumental Analysis Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Procedury badawcze","technique_en":"Liquid chromatography with a laser light scattering detector (HPLC-ELSD)","test_object_en":"Food E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"食品 E 糖含量 仪器分析检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 Procedury badawcze","test_object_zh":"食品 E","methodology_zh":"糖含量","lab_section_zh":"仪器分析检验室"},{"_id":"6a836c58af14b9c0e7b1e3a4","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Żywność E","methodology":"Skład kwasów tłuszczowych (procentowy udział kwasów tłuszczowych w sumie kwasów tłuszczowych), Zawartość kwasu masłowego","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC - FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC - FID)"],"computed":[],"activity":"Skład kwasów tłuszczowych (procentowy udział kwasów tłuszczowych w sumie kwasów tłuszczowych), Zawartość kwasu masłowego\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC - FID)","reference":"PN-EN ISO 12966-2 | PN-EN ISO 12966-4","norm_bases":["PN-EN ISO 12966-2","PN-EN ISO 12966-4"],"lab_section":"Pracownia Analiz Instrumentalnych","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Żywność E Skład kwasów tłuszczowych (procentowy udział kwasów tłuszczowych w sumie kwasów tłuszczowych), Zawartość kwasu masłowego\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC - FID) PN-EN ISO 12966-2 | PN-EN ISO 12966-4 Zywnosc E Sklad kwasow tluszczowych (procentowy udzial kwasow tluszczowych w sumie kwasow tluszczowych), Zawartosc kwasu maslowego\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC - FID) PN-EN ISO 12966-2 | PN-EN ISO 12966-4","categories":["food"],"row_index":74,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Instrumental Analysis Laboratory","methodology_en":"Fatty acid composition (percentage of fatty acids in total fatty acids), Butyric acid content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Food E Fatty acid composition (percentage of fatty acids in total fatty acids), Butyric acid content Gas chromatography with flame ionization detection (GC - FID) Instrumental Analysis Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN ISO 12966-2 | PN-EN ISO 12966-4","technique_en":"Gas chromatography with flame ionization detection (GC - FID)","test_object_en":"Food E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"食品 E 仪器分析检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN ISO 12966-2 | PN-EN ISO 12966-4","test_object_zh":"食品 E","lab_section_zh":"仪器分析检验室"},{"_id":"6a836c58af14b9c0e7b1e3a5","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Żywność E","methodology":"Stężenie acesulfamu-K, aspartamu, sacharyny i kofeiny","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV/VIS)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV/VIS)"],"computed":[],"activity":"Stężenie acesulfamu-K, aspartamu, sacharyny i kofeiny\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV/VIS)","reference":"PN-EN 12856","norm_bases":["PN-EN 12856"],"lab_section":"Pracownia Analiz Instrumentalnych","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Żywność E Stężenie acesulfamu-K, aspartamu, sacharyny i kofeiny\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV/VIS) PN-EN 12856 Zywnosc E Stezenie acesulfamu-K, aspartamu, sacharyny i kofeiny\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC-UV/VIS) PN-EN 12856","categories":["food"],"row_index":75,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Instrumental Analysis Laboratory","methodology_en":"Acesulfame-K, aspartame, saccharin and caffeine concentration","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Food E Acesulfame-K, aspartame, saccharin and caffeine concentration High-performance liquid chromatography with spectrophotometric detection (HPLC-UV/VIS) Instrumental Analysis Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 12856","technique_en":"High-performance liquid chromatography with spectrophotometric detection (HPLC-UV/VIS)","test_object_en":"Food E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"食品 E 高效液相色谱-分光光度检测法（HPLC-UV/VIS） 仪器分析检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 12856","test_object_zh":"食品 E","technique_zh":"高效液相色谱-分光光度检测法（HPLC-UV/VIS）","lab_section_zh":"仪器分析检验室"},{"_id":"6a836c58af14b9c0e7b1e3a6","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość pozostałości ditiokarbaminianów wyrażona jako disiarczek węgla","parameters":[],"technique":"Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej z detekcją spektrometrią mas (HS-GCMS)","techniques":["Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej z detekcją spektrometrią mas (HS-GCMS)"],"computed":[],"activity":"Zawartość pozostałości ditiokarbaminianów wyrażona jako disiarczek węgla\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej z detekcją spektrometrią mas (HS-GCMS)","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Analiz Instrumentalnych","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Żywność E Zawartość pozostałości ditiokarbaminianów wyrażona jako disiarczek węgla\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej z detekcją spektrometrią mas (HS-GCMS) Procedury badawcze Zywnosc E Zawartosc pozostalosci ditiokarbaminianow wyrazona jako disiarczek wegla\nMetoda chromatografii gazowej z analiza fazy nadpowierzchniowej z detekcja spektrometria mas (HS-GCMS) Procedury badawcze","categories":["food"],"row_index":76,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Instrumental Analysis Laboratory","methodology_en":"Content of dithiocarbamate residues expressed as carbon disulphide","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Food E Content of dithiocarbamate residues expressed as carbon disulphide Gas chromatography with headspace analysis with mass spectrometry detection (HS-GCMS) Instrumental Analysis Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Procedury badawcze","technique_en":"Gas chromatography with headspace analysis with mass spectrometry detection (HS-GCMS)","test_object_en":"Food E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"食品 E 仪器分析检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 Procedury badawcze","test_object_zh":"食品 E","lab_section_zh":"仪器分析检验室"},{"_id":"6a836c58af14b9c0e7b1e3a7","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość akryloamidu","parameters":[],"technique":"Metoda chromatografii cieczowej z detektorem tandemową spektrometrią mas (LC-MS/MS)","techniques":["Metoda chromatografii cieczowej z detektorem tandemową spektrometrią mas (LC-MS/MS)"],"computed":[],"activity":"Zawartość akryloamidu\nMetoda chromatografii cieczowej z detektorem tandemową spektrometrią mas (LC-MS/MS)","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Analiz Instrumentalnych","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Żywność E Zawartość akryloamidu\nMetoda chromatografii cieczowej z detektorem tandemową spektrometrią mas (LC-MS/MS) Procedury badawcze Zywnosc E Zawartosc akryloamidu\nMetoda chromatografii cieczowej z detektorem tandemowa spektrometria mas (LC-MS/MS) Procedury badawcze","categories":["food"],"row_index":77,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Instrumental Analysis Laboratory","methodology_en":"Acrylamide content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Food E Acrylamide content Liquid chromatography with a tandem mass spectrometry detector (LC-MS/MS) Instrumental Analysis Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Procedury badawcze","technique_en":"Liquid chromatography with a tandem mass spectrometry detector (LC-MS/MS)","test_object_en":"Food E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"食品 E 丙烯酰胺含量 仪器分析检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 Procedury badawcze","test_object_zh":"食品 E","lab_section_zh":"仪器分析检验室","methodology_zh":"丙烯酰胺含量"},{"_id":"6a836c58af14b9c0e7b1e3a8","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość chloropropanodioli oraz glicydolu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC- MS/MS)","techniques":["Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC- MS/MS)"],"computed":[],"activity":"Zawartość chloropropanodioli oraz glicydolu\nMetoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC- MS/MS)","reference":"PN-EN ISO 18363-3","norm_bases":["PN-EN ISO 18363-3"],"lab_section":"Pracownia Analiz Instrumentalnych","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Żywność E Zawartość chloropropanodioli oraz glicydolu\nMetoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC- MS/MS) PN-EN ISO 18363-3 Zywnosc E Zawartosc chloropropanodioli oraz glicydolu\nMetoda chromatografii gazowej z detekcja tandemowa spektrometria mas (GC- MS/MS) PN-EN ISO 18363-3","categories":["food"],"row_index":78,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Instrumental Analysis Laboratory","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Food E Gas chromatography with tandem mass spectrometry detection (GC- MS/MS) Instrumental Analysis Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN ISO 18363-3","technique_en":"Gas chromatography with tandem mass spectrometry detection (GC- MS/MS)","test_object_en":"Food E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"食品 E 仪器分析检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN ISO 18363-3","test_object_zh":"食品 E","lab_section_zh":"仪器分析检验室"},{"_id":"6a836c58af14b9c0e7b1e3a9","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość tłuszczu mlecznego w g/100g tłuszczu (z obliczeń), Zawartość procentowa tłuszczu mlecznego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość tłuszczu mlecznego w g/100g tłuszczu (z obliczeń), Zawartość procentowa tłuszczu mlecznego (z obliczeń)","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Analiz Instrumentalnych","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Żywność E Zawartość tłuszczu mlecznego w g/100g tłuszczu (z obliczeń), Zawartość procentowa tłuszczu mlecznego (z obliczeń) Procedury badawcze Zywnosc E Zawartosc tluszczu mlecznego w g/100g tluszczu (z obliczen), Zawartosc procentowa tluszczu mlecznego (z obliczen) Procedury badawcze","categories":["food"],"row_index":79,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Instrumental Analysis Laboratory","methodology_en":"Milk fat content in g/100g of fat (calculated), Percentage content of milk fat (calculated)","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Food E Milk fat content in g/100g of fat (calculated), Percentage content of milk fat (calculated) Instrumental Analysis Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Procedury badawcze","test_object_en":"Food E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"食品 E 仪器分析检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 Procedury badawcze","test_object_zh":"食品 E","lab_section_zh":"仪器分析检验室"},{"_id":"6a836c58af14b9c0e7b1e3aa","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Owoce, warzywa, przetwory owocowo - warzywne E","methodology":"Zawartość azotanów i azotynów","parameters":[],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Zawartość azotanów i azotynów\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN 12014-2","norm_bases":["PN-EN 12014-2"],"lab_section":"Pracownia Analiz Instrumentalnych","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Owoce, warzywa, przetwory owocowo - warzywne E Zawartość azotanów i azotynów\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN 12014-2 Owoce, warzywa, przetwory owocowo - warzywne E Zawartosc azotanow i azotynow\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN 12014-2","categories":["other"],"row_index":80,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Instrumental Analysis Laboratory","methodology_en":"Nitrate and nitrite content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Fruit, vegetables, fruit-vegetable products E Nitrate and nitrite content Ion chromatography with conductometric detection (IC-CD) Instrumental Analysis Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN 12014-2","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Fruit, vegetables, fruit-vegetable products E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"硝酸盐与亚硝酸盐含量 离子色谱-电导检测法（IC-CD） 仪器分析检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN 12014-2","technique_zh":"离子色谱-电导检测法（IC-CD）","lab_section_zh":"仪器分析检验室","methodology_zh":"硝酸盐与亚硝酸盐含量"},{"_id":"6a836c58af14b9c0e7b1e3ab","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi E","methodology":"Stężenie pierwiastków","parameters":[{"name":"Twardość wody w mgCaCO3/l (z obliczeń)"}],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"computed":[],"activity":"Stężenie pierwiastków\nTwardość wody w mgCaCO3/l (z obliczeń)\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"PN-EN ISO 17294-2","norm_bases":["PN-EN ISO 17294-2"],"lab_section":"Pracownia Analiz Instrumentalnych","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Woda do spożycia przez ludzi E Stężenie pierwiastków\nTwardość wody w mgCaCO3/l (z obliczeń)\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) PN-EN ISO 17294-2 Woda do spozycia przez ludzi E Stezenie pierwiastkow\nTwardosc wody w mgCaCO3/l (z obliczen)\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) PN-EN ISO 17294-2","categories":["water"],"row_index":81,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Instrumental Analysis Laboratory","methodology_en":"Element concentration","parameters_en":[{"name":"Water hardness in mgCaCO3/l (calculated)"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Water intended for human consumption E Element concentration Inductively coupled plasma mass spectrometry (ICP-MS) Instrumental Analysis Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Water hardness in mgCaCO3/l (calculated) PN-EN ISO 17294-2","technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","test_object_en":"Water intended for human consumption E","methodology_zh":"元素浓度","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"生活饮用水 E 元素浓度 电感耦合等离子体质谱法（ICP-MS） 仪器分析检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN ISO 17294-2","technique_zh":"电感耦合等离子体质谱法（ICP-MS）","lab_section_zh":"仪器分析检验室","test_object_zh":"生活饮用水 E"},{"_id":"6a836c58af14b9c0e7b1e3ac","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi E","methodology":"Oznaczanie anionów","parameters":[],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Oznaczanie anionów\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1","norm_bases":["PN-EN ISO 10304-1"],"lab_section":"Pracownia Analiz Instrumentalnych","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Woda do spożycia przez ludzi E Oznaczanie anionów\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1 Woda do spozycia przez ludzi E Oznaczanie anionow\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1","categories":["water"],"row_index":82,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Instrumental Analysis Laboratory","methodology_en":"Determination of anions","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Water intended for human consumption E Determination of anions Ion chromatography with conductometric detection (IC-CD) Instrumental Analysis Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN ISO 10304-1","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water intended for human consumption E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"生活饮用水 E 离子色谱-电导检测法（IC-CD） 仪器分析检验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN ISO 10304-1","technique_zh":"离子色谱-电导检测法（IC-CD）","lab_section_zh":"仪器分析检验室","test_object_zh":"生活饮用水 E"},{"_id":"6a836c58af14b9c0e7b1e3ad","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Pasze","methodology":"Ogólna liczba bakterii beztlenowych mezofilnych w temperaturze 30°C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba bakterii beztlenowych mezofilnych w temperaturze 30°C\nMetoda płytkowa (posiew wgłębny)","reference":"MP-03725-PL wersja 2 ważna od 16.05.2025","norm_bases":["MP-03725-PL wersja 2 ważna od 16.05.2025"],"lab_section":"Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pasze Ogólna liczba bakterii beztlenowych mezofilnych w temperaturze 30°C\nMetoda płytkowa (posiew wgłębny) MP-03725-PL wersja 2 ważna od 16.05.2025 Pasze Ogolna liczba bakterii beztlenowych mezofilnych w temperaturze 30°C\nMetoda plytkowa (posiew wglebny) MP-03725-PL wersja 2 wazna od 16.05.2025","categories":["food","microbiology"],"row_index":83,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total count of mesophilic anaerobic bacteria at 30°C","search_en":"Feed Total count of mesophilic anaerobic bacteria at 30°C Plate method (pour plate) MP-03725-PL wersja 2 ważna od 16.05.2025","technique_en":"Plate method (pour plate)","test_object_en":"Feed","search_zh":"饲料 平板法（倾注培养） MP-03725-PL wersja 2 ważna od 16.05.2025","technique_zh":"平板法（倾注培养）","test_object_zh":"饲料"},{"_id":"6a836c58af14b9c0e7b1e3ae","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Mięso i przetwory mięsne","methodology":"Trwałość konserw","parameters":[],"technique":"Metoda próby termostatowej","techniques":["Metoda próby termostatowej"],"computed":[],"activity":"Trwałość konserw\nMetoda próby termostatowej","reference":"PN-A-82055-5:1994","norm_bases":["PN-A-82055-5:1994"],"lab_section":"Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i przetwory mięsne Trwałość konserw\nMetoda próby termostatowej PN-A-82055-5:1994 Mieso i przetwory miesne Trwalosc konserw\nMetoda proby termostatowej PN-A-82055-5:1994","categories":["food"],"row_index":84,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Shelf stability of canned products","search_en":"Meat and meat products Shelf stability of canned products Thermostatic test method PN-A-82055-5:1994","technique_en":"Thermostatic test method","test_object_en":"Meat and meat products","search_zh":"肉与肉制品 罐头保存性 恒温试验法 PN-A-82055-5:1994","test_object_zh":"肉与肉制品","methodology_zh":"罐头保存性","technique_zh":"恒温试验法"},{"_id":"6a836c58af14b9c0e7b1e3af","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Mięso i przetwory mięsne","methodology":"Szczelność opakowań hermetycznie zamkniętych","parameters":[],"technique":"Metoda próżniowa","techniques":["Metoda próżniowa"],"computed":[],"activity":"Szczelność opakowań hermetycznie zamkniętych\nMetoda próżniowa","reference":"PN-A-82055-4:1997 + Az1:2002","norm_bases":["PN-A-82055-4:1997 + Az1:2002"],"lab_section":"Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i przetwory mięsne Szczelność opakowań hermetycznie zamkniętych\nMetoda próżniowa PN-A-82055-4:1997 + Az1:2002 Mieso i przetwory miesne Szczelnosc opakowan hermetycznie zamknietych\nMetoda prozniowa PN-A-82055-4:1997 + Az1:2002","categories":["food"],"row_index":85,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Leak tightness of hermetically sealed packaging","search_en":"Meat and meat products Leak tightness of hermetically sealed packaging Vacuum method PN-A-82055-4:1997 + Az1:2002","technique_en":"Vacuum method","test_object_en":"Meat and meat products","search_zh":"肉与肉制品 密闭包装的密封性 真空法 PN-A-82055-4:1997 + Az1:2002","test_object_zh":"肉与肉制品","technique_zh":"真空法","methodology_zh":"密闭包装的密封性"},{"_id":"6a836c58af14b9c0e7b1e3b0","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Przetwory owocowe, owocowo- warzywne i warzywno-mięsne","methodology":"Trwałość konserw","parameters":[],"technique":"Metoda próby termostatowej","techniques":["Metoda próby termostatowej"],"computed":[],"activity":"Trwałość konserw\nMetoda próby termostatowej","reference":"PN-90/A-75052/03","norm_bases":["PN-90/A-75052/03"],"lab_section":"Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przetwory owocowe, owocowo- warzywne i warzywno-mięsne Trwałość konserw\nMetoda próby termostatowej PN-90/A-75052/03 Przetwory owocowe, owocowo- warzywne i warzywno-miesne Trwalosc konserw\nMetoda proby termostatowej PN-90/A-75052/03","categories":["other"],"row_index":86,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Shelf stability of canned products","search_en":"Shelf stability of canned products Thermostatic test method PN-90/A-75052/03","technique_en":"Thermostatic test method","methodology_zh":"罐头保存性","search_zh":"罐头保存性 恒温试验法 PN-90/A-75052/03","technique_zh":"恒温试验法"},{"_id":"6a836c58af14b9c0e7b1e3b1","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Przetwory owocowe, owocowo- warzywne i warzywno-mięsne","methodology":"Szczelność opakowań hermetycznie zamkniętych","parameters":[],"technique":"Metoda próżniowa","techniques":["Metoda próżniowa"],"computed":[],"activity":"Szczelność opakowań hermetycznie zamkniętych\nMetoda próżniowa","reference":"PN-90/A-75052/02","norm_bases":["PN-90/A-75052/02"],"lab_section":"Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przetwory owocowe, owocowo- warzywne i warzywno-mięsne Szczelność opakowań hermetycznie zamkniętych\nMetoda próżniowa PN-90/A-75052/02 Przetwory owocowe, owocowo- warzywne i warzywno-miesne Szczelnosc opakowan hermetycznie zamknietych\nMetoda prozniowa PN-90/A-75052/02","categories":["other"],"row_index":87,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Leak tightness of hermetically sealed packaging","search_en":"Leak tightness of hermetically sealed packaging Vacuum method PN-90/A-75052/02","technique_en":"Vacuum method","search_zh":"密闭包装的密封性 真空法 PN-90/A-75052/02","technique_zh":"真空法","methodology_zh":"密闭包装的密封性"},{"_id":"6a836c58af14b9c0e7b1e3b2","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007","norm_bases":["PN-EN ISO 19458:2007"],"lab_section":"Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 Woda do spozycia przez ludzi Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007","categories":["water","microbiology"],"row_index":88,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for microbiological testing","search_en":"Water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007","test_object_en":"Water intended for human consumption","methodology_zh":"微生物检测用样品采集","search_zh":"生活饮用水 微生物检测用样品采集 PN-EN ISO 19458:2007","test_object_zh":"生活饮用水"},{"_id":"6a836c58af14b9c0e7b1e3b3","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Próbki środowiskowe z obszaru produkcji i obrotu żywnością: - wymaz z powierzchni ograniczonej szablonem - wymazy z powierzchni nieograniczonej szablonem -odcisk z powierzchni","methodology":"Pobieranie próbek z powierzchni do badań mikrobiologicznych.","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek z powierzchni do badań mikrobiologicznych.","reference":"PN-EN ISO 18593:2018-08","norm_bases":["PN-EN ISO 18593:2018-08"],"lab_section":"Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Próbki środowiskowe z obszaru produkcji i obrotu żywnością: - wymaz z powierzchni ograniczonej szablonem - wymazy z powierzchni nieograniczonej szablonem -odcisk z powierzchni Pobieranie próbek z powierzchni do badań mikrobiologicznych. PN-EN ISO 18593:2018-08 Probki srodowiskowe z obszaru produkcji i obrotu zywnoscia: - wymaz z powierzchni ograniczonej szablonem - wymazy z powierzchni nieograniczonej szablonem -odcisk z powierzchni Pobieranie probek z powierzchni do badan mikrobiologicznych. PN-EN ISO 18593:2018-08","categories":["food","environment","microbiology"],"row_index":89,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Surface sampling for microbiological testing.","search_en":"Environmental samples from the food production and distribution area: - swab from an area delimited by a template - swabs from an area not delimited by a template -surface imprint Surface sampling for microbiological testing. PN-EN ISO 18593:2018-08","test_object_en":"Environmental samples from the food production and distribution area: - swab from an area delimited by a template - swabs from an area not delimited by a template -surface imprint"},{"_id":"6a836c58af14b9c0e7b1e3b4","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Żywność, Pasze, Próbki środowiskowe z obszaru produkcji i obrotu żywnością - wymaz","methodology":"Obecność materiału genetycznego Listeria monocytogenes","parameters":[],"technique":"Metoda Real-time PCR","techniques":["Metoda Real-time PCR"],"computed":[],"activity":"Obecność materiału genetycznego Listeria monocytogenes\nMetoda Real-time PCR","reference":"MP-03877-PL wersja 2 ważna od 08.04.2026","norm_bases":["MP-03877-PL wersja 2 ważna od 08.04.2026"],"lab_section":"Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Żywność, Pasze, Próbki środowiskowe z obszaru produkcji i obrotu żywnością - wymaz Obecność materiału genetycznego Listeria monocytogenes\nMetoda Real-time PCR MP-03877-PL wersja 2 ważna od 08.04.2026 Zywnosc, Pasze, Probki srodowiskowe z obszaru produkcji i obrotu zywnoscia - wymaz Obecnosc materialu genetycznego Listeria monocytogenes\nMetoda Real-time PCR MP-03877-PL wersja 2 wazna od 08.04.2026","categories":["food","materials","environment","microbiology"],"row_index":90,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Real-time PCR method MP-03877-PL wersja 2 ważna od 08.04.2026","technique_en":"Real-time PCR method","search_zh":"实时荧光定量 PCR 法 MP-03877-PL wersja 2 ważna od 08.04.2026","technique_zh":"实时荧光定量 PCR 法"},{"_id":"6a836c58af14b9c0e7b1e3b5","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Żywność, Pasze, Próbki środowiskowe z obszaru produkcji i obrotu żywnością - wymaz","methodology":"Obecność materiału genetycznego Salmonella spp.","parameters":[],"technique":"Metoda Real-time PCR","techniques":["Metoda Real-time PCR"],"computed":[],"activity":"Obecność materiału genetycznego Salmonella spp.\nMetoda Real-time PCR","reference":"MP-03875-PL wersja 2 ważna od 08.04.2026","norm_bases":["MP-03875-PL wersja 2 ważna od 08.04.2026"],"lab_section":"Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Żywność, Pasze, Próbki środowiskowe z obszaru produkcji i obrotu żywnością - wymaz Obecność materiału genetycznego Salmonella spp.\nMetoda Real-time PCR MP-03875-PL wersja 2 ważna od 08.04.2026 Zywnosc, Pasze, Probki srodowiskowe z obszaru produkcji i obrotu zywnoscia - wymaz Obecnosc materialu genetycznego Salmonella spp.\nMetoda Real-time PCR MP-03875-PL wersja 2 wazna od 08.04.2026","categories":["food","microbiology","materials","environment"],"row_index":91,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Real-time PCR method MP-03875-PL wersja 2 ważna od 08.04.2026","technique_en":"Real-time PCR method","search_zh":"实时荧光定量 PCR 法 MP-03875-PL wersja 2 ważna od 08.04.2026","technique_zh":"实时荧光定量 PCR 法"},{"_id":"6a836c58af14b9c0e7b1e3b6","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Żywność, Pasze, Próbki środowiskowe z obszaru produkcji i obrotu żywnością - wymaz","methodology":"Liczba drożdży i pleśni","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba drożdży i pleśni\nMetoda płytkowa (posiew wgłębny)","reference":"MP-03914-PL wersja 2 ważna od 08.04.2026","norm_bases":["MP-03914-PL wersja 2 ważna od 08.04.2026"],"lab_section":"Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Żywność, Pasze, Próbki środowiskowe z obszaru produkcji i obrotu żywnością - wymaz Liczba drożdży i pleśni\nMetoda płytkowa (posiew wgłębny) MP-03914-PL wersja 2 ważna od 08.04.2026 Zywnosc, Pasze, Probki srodowiskowe z obszaru produkcji i obrotu zywnoscia - wymaz Liczba drozdzy i plesni\nMetoda plytkowa (posiew wglebny) MP-03914-PL wersja 2 wazna od 08.04.2026","categories":["food","environment"],"row_index":92,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Yeast and mould count","search_en":"Yeast and mould count Plate method (pour plate) MP-03914-PL wersja 2 ważna od 08.04.2026","technique_en":"Plate method (pour plate)","methodology_zh":"酵母菌与霉菌计数","search_zh":"酵母菌与霉菌计数 平板法（倾注培养） MP-03914-PL wersja 2 ważna od 08.04.2026","technique_zh":"平板法（倾注培养）"},{"_id":"6a836c58af14b9c0e7b1e3b7","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Zagęszczone soki owocowe, Soki owocowe, warzywne, Nektary, napoje, Surowce do produkcji napojów i soków","methodology":"Liczba termofilnych kwasolubnych bakterii przetrwalnikujących (Alicyclobacillus spp.)","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba termofilnych kwasolubnych bakterii przetrwalnikujących (Alicyclobacillus spp.)\nMetoda filtracji membranowej","reference":"IFU Method of Analysis No. 12 (2019) – procedura B","norm_bases":["IFU Method of Analysis No. 12 (2019) – procedura B"],"lab_section":"Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Zagęszczone soki owocowe, Soki owocowe, warzywne, Nektary, napoje, Surowce do produkcji napojów i soków Liczba termofilnych kwasolubnych bakterii przetrwalnikujących (Alicyclobacillus spp.)\nMetoda filtracji membranowej IFU Method of Analysis No. 12 (2019) – procedura B Zageszczone soki owocowe, Soki owocowe, warzywne, Nektary, napoje, Surowce do produkcji napojow i sokow Liczba termofilnych kwasolubnych bakterii przetrwalnikujacych (Alicyclobacillus spp.)\nMetoda filtracji membranowej IFU Method of Analysis No. 12 (2019) – procedura B","categories":["food","microbiology"],"row_index":93,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Count of thermophilic acidophilic spore-forming bacteria (Alicyclobacillus spp.)","search_en":"Fruit juice concentrates, Fruit and vegetable juices, Nectars, beverages, Raw materials for the production of beverages and juices Count of thermophilic acidophilic spore-forming bacteria (Alicyclobacillus spp.) Membrane filtration method IFU Method of Analysis No. 12 (2019) – procedura B","technique_en":"Membrane filtration method","test_object_en":"Fruit juice concentrates, Fruit and vegetable juices, Nectars, beverages, Raw materials for the production of beverages and juices","search_zh":"浓缩果汁、果汁与蔬菜汁、果蜜、饮料，饮料与果汁生产用原料 膜过滤法 IFU Method of Analysis No. 12 (2019) – procedura B","technique_zh":"膜过滤法","test_object_zh":"浓缩果汁、果汁与蔬菜汁、果蜜、饮料，饮料与果汁生产用原料"},{"_id":"6a836c58af14b9c0e7b1e3b8","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Zagęszczone soki owocowe, Soki owocowe, warzywne, Nektary, napoje, Surowce do produkcji napojów i soków","methodology":"Liczba termofilnych kwasolubnych bakterii przetrwalnikujących (Alicyclobacillus spp.)","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba termofilnych kwasolubnych bakterii przetrwalnikujących (Alicyclobacillus spp.)\nMetoda płytkowa (posiew wgłębny)","reference":"IFU Method of Analysis No. 12 (2019) – procedura A","norm_bases":["IFU Method of Analysis No. 12 (2019) – procedura A"],"lab_section":"Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Zagęszczone soki owocowe, Soki owocowe, warzywne, Nektary, napoje, Surowce do produkcji napojów i soków Liczba termofilnych kwasolubnych bakterii przetrwalnikujących (Alicyclobacillus spp.)\nMetoda płytkowa (posiew wgłębny) IFU Method of Analysis No. 12 (2019) – procedura A Zageszczone soki owocowe, Soki owocowe, warzywne, Nektary, napoje, Surowce do produkcji napojow i sokow Liczba termofilnych kwasolubnych bakterii przetrwalnikujacych (Alicyclobacillus spp.)\nMetoda plytkowa (posiew wglebny) IFU Method of Analysis No. 12 (2019) – procedura A","categories":["food","microbiology"],"row_index":94,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Count of thermophilic acidophilic spore-forming bacteria (Alicyclobacillus spp.)","search_en":"Fruit juice concentrates, Fruit and vegetable juices, Nectars, beverages, Raw materials for the production of beverages and juices Count of thermophilic acidophilic spore-forming bacteria (Alicyclobacillus spp.) Plate method (pour plate) IFU Method of Analysis No. 12 (2019) – procedura A","technique_en":"Plate method (pour plate)","test_object_en":"Fruit juice concentrates, Fruit and vegetable juices, Nectars, beverages, Raw materials for the production of beverages and juices","search_zh":"浓缩果汁、果汁与蔬菜汁、果蜜、饮料，饮料与果汁生产用原料 平板法（倾注培养） IFU Method of Analysis No. 12 (2019) – procedura A","technique_zh":"平板法（倾注培养）","test_object_zh":"浓缩果汁、果汁与蔬菜汁、果蜜、饮料，饮料与果汁生产用原料"},{"_id":"6a836c58af14b9c0e7b1e3b9","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Zagęszczone soki owocowe, Soki owocowe, warzywne, Nektary, napoje, Surowce do produkcji napojów i soków","methodology":"Obecność termofilnych kwasolubnych bakterii przetrwalnikujących (Alicyclobacillus spp.)","parameters":[],"technique":"Metoda hodowlana","techniques":["Metoda hodowlana"],"computed":[],"activity":"Obecność termofilnych kwasolubnych bakterii przetrwalnikujących (Alicyclobacillus spp.)\nMetoda hodowlana","reference":"IFU Method of Analysis No. 12 (2019) – procedura C","norm_bases":["IFU Method of Analysis No. 12 (2019) – procedura C"],"lab_section":"Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Zagęszczone soki owocowe, Soki owocowe, warzywne, Nektary, napoje, Surowce do produkcji napojów i soków Obecność termofilnych kwasolubnych bakterii przetrwalnikujących (Alicyclobacillus spp.)\nMetoda hodowlana IFU Method of Analysis No. 12 (2019) – procedura C Zageszczone soki owocowe, Soki owocowe, warzywne, Nektary, napoje, Surowce do produkcji napojow i sokow Obecnosc termofilnych kwasolubnych bakterii przetrwalnikujacych (Alicyclobacillus spp.)\nMetoda hodowlana IFU Method of Analysis No. 12 (2019) – procedura C","categories":["food","microbiology"],"row_index":95,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of thermophilic acidophilic spore-forming bacteria (Alicyclobacillus spp.)","search_en":"Fruit juice concentrates, Fruit and vegetable juices, Nectars, beverages, Raw materials for the production of beverages and juices Presence of thermophilic acidophilic spore-forming bacteria (Alicyclobacillus spp.) Culture method IFU Method of Analysis No. 12 (2019) – procedura C","technique_en":"Culture method","test_object_en":"Fruit juice concentrates, Fruit and vegetable juices, Nectars, beverages, Raw materials for the production of beverages and juices","search_zh":"浓缩果汁、果汁与蔬菜汁、果蜜、饮料，饮料与果汁生产用原料 培养法 IFU Method of Analysis No. 12 (2019) – procedura C","technique_zh":"培养法","test_object_zh":"浓缩果汁、果汁与蔬菜汁、果蜜、饮料，饮料与果汁生产用原料"},{"_id":"6a836c58af14b9c0e7b1e3ba","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Żywność E, Pasze E","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny)","reference":"Normy | Procedury badawcze","norm_bases":["Normy","Procedury badawcze"],"lab_section":"Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Żywność E, Pasze E Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny) Normy | Procedury badawcze Zywnosc E, Pasze E Liczba drobnoustrojow\nMetoda plytkowa (posiew wglebny) Normy | Procedury badawcze","categories":["food","microbiology"],"row_index":96,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Microorganism count","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Food E, Feed E Microorganism count Plate method (pour plate) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Normy | Procedury badawcze","technique_en":"Plate method (pour plate)","test_object_en":"Food E, Feed E","methodology_zh":"菌落总数","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"食品 E、饲料 E 菌落总数 平板法（倾注培养） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 Normy | Procedury badawcze","technique_zh":"平板法（倾注培养）","test_object_zh":"食品 E、饲料 E"},{"_id":"6a836c58af14b9c0e7b1e3bb","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Żywność E, Pasze E","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym","reference":"Normy | Procedury badawcze","norm_bases":["Normy","Procedury badawcze"],"lab_section":"Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Żywność E, Pasze E Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym Normy | Procedury badawcze Zywnosc E, Pasze E Obecnosc drobnoustrojow\nMetoda hodowlana z potwierdzeniem biochemicznym Normy | Procedury badawcze","categories":["food","microbiology"],"row_index":97,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of microorganisms","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Food E, Feed E Presence of microorganisms Culture method with biochemical confirmation E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Normy | Procedury badawcze","technique_en":"Culture method with biochemical confirmation","test_object_en":"Food E, Feed E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"食品 E、饲料 E 微生物的检出 培养法结合生化确认 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 Normy | Procedury badawcze","technique_zh":"培养法结合生化确认","methodology_zh":"微生物的检出","test_object_zh":"食品 E、饲料 E"},{"_id":"6a836c58af14b9c0e7b1e3bc","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Żywność E, Pasze E","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda płytkowa (posiew powierzchniowy)"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda płytkowa (posiew powierzchniowy)","reference":"Normy | Procedury badawcze","norm_bases":["Normy","Procedury badawcze"],"lab_section":"Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Żywność E, Pasze E Liczba drobnoustrojów\nMetoda płytkowa (posiew powierzchniowy) Normy | Procedury badawcze Zywnosc E, Pasze E Liczba drobnoustrojow\nMetoda plytkowa (posiew powierzchniowy) Normy | Procedury badawcze","categories":["food","microbiology"],"row_index":98,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Microorganism count","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Food E, Feed E Microorganism count Plate method (spread plate) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Normy | Procedury badawcze","technique_en":"Plate method (spread plate)","test_object_en":"Food E, Feed E","methodology_zh":"菌落总数","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"食品 E、饲料 E 菌落总数 平板法（表面涂布） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 Normy | Procedury badawcze","technique_zh":"平板法（表面涂布）","test_object_zh":"食品 E、饲料 E"},{"_id":"6a836c58af14b9c0e7b1e3bd","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Żywność E","methodology":"Najbardziej prawdopodobna liczba drobnoustrojów","parameters":[],"technique":"Metoda NPL probówkowa","techniques":["Metoda NPL probówkowa"],"computed":[],"activity":"Najbardziej prawdopodobna liczba drobnoustrojów\nMetoda NPL probówkowa","reference":"Normy","norm_bases":["Normy"],"lab_section":"Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Żywność E Najbardziej prawdopodobna liczba drobnoustrojów\nMetoda NPL probówkowa Normy Zywnosc E Najbardziej prawdopodobna liczba drobnoustrojow\nMetoda NPL probowkowa Normy","categories":["food","microbiology"],"row_index":99,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Most probable number of microorganisms","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Food E Most probable number of microorganisms MPN tube method E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Normy","technique_en":"MPN tube method","test_object_en":"Food E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"食品 E 微生物最可能数 试管 MPN 法 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 Normy","test_object_zh":"食品 E","methodology_zh":"微生物最可能数","technique_zh":"试管 MPN 法"},{"_id":"6a836c58af14b9c0e7b1e3be","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Żywność E","methodology":"Liczba przypuszczalnych Pseudomonas spp.","parameters":[],"technique":"Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda płytkowa (posiew powierzchniowy)"],"computed":[],"activity":"Liczba przypuszczalnych Pseudomonas spp.\nMetoda płytkowa (posiew powierzchniowy)","reference":"PN ISO 13720","norm_bases":["PN ISO 13720"],"lab_section":"Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Żywność E Liczba przypuszczalnych Pseudomonas spp.\nMetoda płytkowa (posiew powierzchniowy) PN ISO 13720 Zywnosc E Liczba przypuszczalnych Pseudomonas spp.\nMetoda plytkowa (posiew powierzchniowy) PN ISO 13720","categories":["food"],"row_index":100,"parse_version":4,"parse_source":"agent-claude-code","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Food E Plate method (spread plate) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN ISO 13720","technique_en":"Plate method (spread plate)","test_object_en":"Food E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"食品 E 平板法（表面涂布） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN ISO 13720","technique_zh":"平板法（表面涂布）","test_object_zh":"食品 E"},{"_id":"6a836c58af14b9c0e7b1e3bf","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Żywność E","methodology":"Liczba enterokoków","parameters":[],"technique":"Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda płytkowa (posiew powierzchniowy)"],"computed":[],"activity":"Liczba enterokoków\nMetoda płytkowa (posiew powierzchniowy)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Żywność E Liczba enterokoków\nMetoda płytkowa (posiew powierzchniowy) Normy Zywnosc E Liczba enterokokow\nMetoda plytkowa (posiew powierzchniowy) Normy","categories":["food"],"row_index":101,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Enterococci count","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Food E Enterococci count Plate method (spread plate) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Normy","technique_en":"Plate method (spread plate)","test_object_en":"Food E","methodology_zh":"肠球菌计数","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"食品 E 肠球菌计数 平板法（表面涂布） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 Normy","technique_zh":"平板法（表面涂布）","test_object_zh":"食品 E"},{"_id":"6a836c58af14b9c0e7b1e3c0","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Woda E","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Woda E Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny) Normy Woda E Liczba drobnoustrojow\nMetoda plytkowa (posiew wglebny) Normy","categories":["water","microbiology"],"row_index":102,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Microorganism count","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Water E Microorganism count Plate method (pour plate) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Normy","technique_en":"Plate method (pour plate)","test_object_en":"Water E","methodology_zh":"菌落总数","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"水 E 菌落总数 平板法（倾注培养） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 Normy","technique_zh":"平板法（倾注培养）","test_object_zh":"水 E"},{"_id":"6a836c58af14b9c0e7b1e3c1","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Woda E","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda filtracji membranowej","reference":"Normy","norm_bases":["Normy"],"lab_section":"Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Woda E Liczba drobnoustrojów\nMetoda filtracji membranowej Normy Woda E Liczba drobnoustrojow\nMetoda filtracji membranowej Normy","categories":["water","microbiology"],"row_index":103,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Microorganism count","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Water E Microorganism count Membrane filtration method E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Normy","technique_en":"Membrane filtration method","test_object_en":"Water E","methodology_zh":"菌落总数","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"水 E 菌落总数 膜过滤法 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 Normy","technique_zh":"膜过滤法","test_object_zh":"水 E"},{"_id":"6a836c58af14b9c0e7b1e3c2","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Kosmetyki E, Surowce i półprodukty do produkcji kosmetyków, Artykuły higieniczne","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym","reference":"Normy","norm_bases":["Normy"],"lab_section":"Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Kosmetyki E, Surowce i półprodukty do produkcji kosmetyków, Artykuły higieniczne Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym Normy Kosmetyki E, Surowce i polprodukty do produkcji kosmetykow, Artykuly higieniczne Obecnosc drobnoustrojow\nMetoda hodowlana z potwierdzeniem biochemicznym Normy","categories":["microbiology","pharma"],"row_index":104,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of microorganisms","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Presence of microorganisms Culture method with biochemical confirmation E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Normy","technique_en":"Culture method with biochemical confirmation","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"微生物的检出 培养法结合生化确认 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 Normy","technique_zh":"培养法结合生化确认","methodology_zh":"微生物的检出"},{"_id":"6a836c58af14b9c0e7b1e3c3","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Kosmetyki E, Surowce i półprodukty do produkcji kosmetyków, Artykuły higieniczne","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Kosmetyki E, Surowce i półprodukty do produkcji kosmetyków, Artykuły higieniczne Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny) Normy Kosmetyki E, Surowce i polprodukty do produkcji kosmetykow, Artykuly higieniczne Liczba drobnoustrojow\nMetoda plytkowa (posiew wglebny) Normy","categories":["microbiology","pharma"],"row_index":105,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Microorganism count","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Microorganism count Plate method (pour plate) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Normy","technique_en":"Plate method (pour plate)","methodology_zh":"菌落总数","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"菌落总数 平板法（倾注培养） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 Normy","technique_zh":"平板法（倾注培养）"},{"_id":"6a836c58af14b9c0e7b1e3c4","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Tusze zwierząt rzeźnych E -wymaz -wycinki","methodology":"Obecność Salmonella spp.","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność Salmonella spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PN-EN ISO 6579","norm_bases":["PN-EN ISO 6579"],"lab_section":"Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Tusze zwierząt rzeźnych E -wymaz -wycinki Obecność Salmonella spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579 Tusze zwierzat rzeznych E -wymaz -wycinki Obecnosc Salmonella spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579","categories":["microbiology"],"row_index":106,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of Salmonella spp.","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Presence of Salmonella spp. Culture method with biochemical and serological confirmation E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN ISO 6579","technique_en":"Culture method with biochemical and serological confirmation","methodology_zh":"沙门氏菌属（Salmonella spp.）的检出","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"沙门氏菌属（Salmonella spp.）的检出 培养法结合生化与血清学确认 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN ISO 6579","technique_zh":"培养法结合生化与血清学确认"},{"_id":"6a836c58af14b9c0e7b1e3c5","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Tusze zwierząt rzeźnych E -wymaz -wycinki","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Tusze zwierząt rzeźnych E -wymaz -wycinki Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny) Normy Tusze zwierzat rzeznych E -wymaz -wycinki Liczba drobnoustrojow\nMetoda plytkowa (posiew wglebny) Normy","categories":["microbiology"],"row_index":107,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Microorganism count","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Microorganism count Plate method (pour plate) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Normy","technique_en":"Plate method (pour plate)","methodology_zh":"菌落总数","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"菌落总数 平板法（倾注培养） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 Normy","technique_zh":"平板法（倾注培养）"},{"_id":"6a836c58af14b9c0e7b1e3c6","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Próbki środowiskowe z obszaru produkcji i obrotu żywnością E -wymaz","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Próbki środowiskowe z obszaru produkcji i obrotu żywnością E -wymaz Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny) Normy Probki srodowiskowe z obszaru produkcji i obrotu zywnoscia E -wymaz Liczba drobnoustrojow\nMetoda plytkowa (posiew wglebny) Normy","categories":["food","environment","microbiology"],"row_index":108,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Microorganism count","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Microorganism count Plate method (pour plate) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Normy","technique_en":"Plate method (pour plate)","methodology_zh":"菌落总数","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"菌落总数 平板法（倾注培养） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 Normy","technique_zh":"平板法（倾注培养）"},{"_id":"6a836c58af14b9c0e7b1e3c7","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Próbki środowiskowe z obszaru produkcji i obrotu żywnością E -wymaz","methodology":"Obecność Salmonella spp.","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność Salmonella spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PN-EN ISO 6579","norm_bases":["PN-EN ISO 6579"],"lab_section":"Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Próbki środowiskowe z obszaru produkcji i obrotu żywnością E -wymaz Obecność Salmonella spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579 Probki srodowiskowe z obszaru produkcji i obrotu zywnoscia E -wymaz Obecnosc Salmonella spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579","categories":["microbiology","food","environment"],"row_index":109,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of Salmonella spp.","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Presence of Salmonella spp. Culture method with biochemical and serological confirmation E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN ISO 6579","technique_en":"Culture method with biochemical and serological confirmation","methodology_zh":"沙门氏菌属（Salmonella spp.）的检出","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"沙门氏菌属（Salmonella spp.）的检出 培养法结合生化与血清学确认 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN ISO 6579","technique_zh":"培养法结合生化与血清学确认"},{"_id":"6a836c58af14b9c0e7b1e3c8","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Próbki środowiskowe z obszaru produkcji i obrotu żywnością E -wymaz","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym","reference":"Normy | Procedury badawcze","norm_bases":["Normy","Procedury badawcze"],"lab_section":"Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Próbki środowiskowe z obszaru produkcji i obrotu żywnością E -wymaz Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym Normy | Procedury badawcze Probki srodowiskowe z obszaru produkcji i obrotu zywnoscia E -wymaz Obecnosc drobnoustrojow\nMetoda hodowlana z potwierdzeniem biochemicznym Normy | Procedury badawcze","categories":["food","environment","microbiology"],"row_index":110,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of microorganisms","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Presence of microorganisms Culture method with biochemical confirmation E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Normy | Procedury badawcze","technique_en":"Culture method with biochemical confirmation","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"微生物的检出 培养法结合生化确认 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 Normy | Procedury badawcze","technique_zh":"培养法结合生化确认","methodology_zh":"微生物的检出"},{"_id":"6a836c58af14b9c0e7b1e3c9","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Próbki środowiskowe z obszaru produkcji i obrotu żywnościąE -odcisk z powierzchni","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda płytek kontaktowych","techniques":["Metoda płytek kontaktowych"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda płytek kontaktowych","reference":"PN-EN ISO 18593","norm_bases":["PN-EN ISO 18593"],"lab_section":"Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Próbki środowiskowe z obszaru produkcji i obrotu żywnościąE -odcisk z powierzchni Liczba drobnoustrojów\nMetoda płytek kontaktowych PN-EN ISO 18593 Probki srodowiskowe z obszaru produkcji i obrotu zywnosciaE -odcisk z powierzchni Liczba drobnoustrojow\nMetoda plytek kontaktowych PN-EN ISO 18593","categories":["food","environment","microbiology"],"row_index":111,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Microorganism count","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Microorganism count Contact plate method E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN ISO 18593","technique_en":"Contact plate method","methodology_zh":"菌落总数","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"菌落总数 接触平皿法 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN ISO 18593","technique_zh":"接触平皿法"},{"_id":"6a836c58af14b9c0e7b1e3ca","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Żywność E","methodology":"Obecność materiału genetycznego Norowirusów","parameters":[],"technique":"Metoda real-time RT-PCR","techniques":["Metoda real-time RT-PCR"],"computed":[],"activity":"Obecność materiału genetycznego Norowirusów\nMetoda real-time RT-PCR","reference":"PN-EN ISO 15216-1","norm_bases":["PN-EN ISO 15216-1"],"lab_section":"Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Żywność E Obecność materiału genetycznego Norowirusów\nMetoda real-time RT-PCR PN-EN ISO 15216-1 Zywnosc E Obecnosc materialu genetycznego Norowirusow\nMetoda real-time RT-PCR PN-EN ISO 15216-1","categories":["food","materials"],"row_index":112,"parse_version":4,"parse_source":"agent-claude-code","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Food E Real-time RT-PCR method E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN ISO 15216-1","technique_en":"Real-time RT-PCR method","test_object_en":"Food E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"食品 E 实时荧光定量 RT-PCR 法 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN ISO 15216-1","test_object_zh":"食品 E","technique_zh":"实时荧光定量 RT-PCR 法"},{"_id":"6a836c58af14b9c0e7b1e3cb","lab_id":"69ad52a3de79e566650fb239","country":"PL","accr_number":"AB 444","accr_body":"PCA","test_object":"Żywność E","methodology":"Obecność materiału genetycznego Hepatitis A","parameters":[],"technique":"Metoda real-time RT-PCR","techniques":["Metoda real-time RT-PCR"],"computed":[],"activity":"Obecność materiału genetycznego Hepatitis A\nMetoda real-time RT-PCR","reference":"PN-EN ISO 15216-1","norm_bases":["PN-EN ISO 15216-1"],"lab_section":"Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.","flexible":false,"search_text":"Żywność E Obecność materiału genetycznego Hepatitis A\nMetoda real-time RT-PCR PN-EN ISO 15216-1 Zywnosc E Obecnosc materialu genetycznego Hepatitis A\nMetoda real-time RT-PCR PN-EN ISO 15216-1","categories":["food","materials"],"row_index":113,"parse_version":4,"parse_source":"agent-claude-code","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.","search_en":"Food E Real-time RT-PCR method E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. PN-EN ISO 15216-1","technique_en":"Real-time RT-PCR method","test_object_en":"Food E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。","search_zh":"食品 E 实时荧光定量 RT-PCR 法 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。 PN-EN ISO 15216-1","test_object_zh":"食品 E","technique_zh":"实时荧光定量 RT-PCR 法"}],"has_pdf":true}