{"lab":{"_id":"69ad52a3de79e566650fb21b","accr_number":"AB 421","country":"PL","accr_body":"PCA","address":"LABORATORIUM GEOTECHNIKI I BADANIA PALI, ul. Instytutowa 1, 03-302 Warszawa","categories":["construction"],"city":"Warszawa","imported_at":"2026-03-08T10:42:43.265Z","methods_count":19,"name":"INSTYTUT BADAWCZY DRÓG I MOSTÓW","parse_status":"parsed","parse_version":2,"pdf_files":["AB_421.pdf"],"scope_summary":"","search_text":"instytut badawczy dróg i mostów laboratorium geotechniki i badania pali, ul. instytutowa 1, 03-302 warszawa other materials construction","status":"active","updated_at":"2026-03-08T14:51:15.896Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:15.896Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20421,podmiot.html","fields_of_testing":[{"codes":"J/5","pl":"Badania mechaniczne materiałów i obiektów budowlanych","en":"Mechanical tests of building materials, building items"},{"codes":"N/5","pl":"Badania właściwości fizycznych materiałów i obiektów budowlanych","en":"Tests of physical properties of building materials, building items"}],"issue":{"no":"22","date":"10.12.2025"},"parse_date":"2026-07-20T07:09:37.814Z","parse_source":"script-pdfplumber","map_coord":[52.267295,21.025067],"map_geo":"nominatim-street","has_en":true,"category_counts":{"other":15,"construction":4},"category_scores":{"other":11.84,"construction":0.84},"has_zh":true},"methods":[{"_id":"6a5dc9b1f1c10c8ce825bc17","lab_id":"69ad52a3de79e566650fb21b","country":"PL","accr_number":"AB 421","accr_body":"PCA","test_object":"Grunty","test_object_en":"Ground","methodology":"Uziarnienie","methodology_en":"Grading","parameters":[{"name":"Zakres","range":"(0- 0,063) mm"},{"name":"Zakres","range":"(0,063-40) mm"}],"parameters_en":[{"name":"Range","range":"(0- 0,063) mm"},{"name":"Range","range":"(0,063-40) mm"}],"technique":"Metoda: analiza areometryczna; Metoda: analiza sitowa","techniques":["Metoda: analiza areometryczna","Metoda: analiza sitowa"],"technique_en":"Method: hydrometer analysis; Method: sieve analysis","computed":[],"computed_en":[],"activity":"Uziarnienie\nZakres:\nZakres (0- 0,063) mm\nZakres (0,063-40) mm\nMetoda: analiza areometryczna; Metoda: analiza sitowa","reference":"PN-B-04481:1988","norm_bases":["PN-B-04481:1988"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Grunty Uziarnienie\nZakres:\nZakres (0- 0,063) mm\nZakres (0,063-40) mm\nMetoda: analiza areometryczna; Metoda: analiza sitowa PN-B-04481:1988 Grunty Uziarnienie\nZakres:\nZakres (0- 0,063) mm\nZakres (0,063-40) mm\nMetoda: analiza areometryczna; Metoda: analiza sitowa PN-B-04481:1988","categories":["other"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Ground Grading Method: hydrometer analysis; Method: sieve analysis Range Range PN-B-04481:1988","parameters_zh":[{"name":"范围","range":"(0- 0,063) mm"},{"name":"范围","range":"(0,063-40) mm"}],"search_zh":"土体 级配 范围 范围 PN-B-04481:1988","test_object_zh":"土体","methodology_zh":"级配"},{"_id":"6a5dc9b1f1c10c8ce825bc18","lab_id":"69ad52a3de79e566650fb21b","country":"PL","accr_number":"AB 421","accr_body":"PCA","test_object":"Grunty","test_object_en":"Ground","methodology":"Wilgotność optymalna Maksymalna gęstość objętościowa szkieletu gruntowego","methodology_en":"Optimum moisture content Maximum dry density of the soil skeleton","parameters":[{"name":"Zakres","range":"(0,70 – 3,50) g/cm3"}],"parameters_en":[{"name":"Range","range":"(0,70 – 3,50) g/cm3"}],"technique":"Metoda: Proctora","techniques":["Metoda: Proctora"],"technique_en":"Method: Proctor","computed":[],"computed_en":[],"activity":"Wilgotność optymalna Maksymalna gęstość objętościowa szkieletu gruntowego\nZakres (0,70 – 3,50) g/cm3\nMetoda: Proctora","reference":"PN-B-04481:1988","norm_bases":["PN-B-04481:1988"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Grunty Wilgotność optymalna Maksymalna gęstość objętościowa szkieletu gruntowego\nZakres (0,70 – 3,50) g/cm3\nMetoda: Proctora PN-B-04481:1988 Grunty Wilgotnosc optymalna Maksymalna gestosc objetosciowa szkieletu gruntowego\nZakres (0,70 – 3,50) g/cm3\nMetoda: Proctora PN-B-04481:1988","categories":["other"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Ground Optimum moisture content Maximum dry density of the soil skeleton Method: Proctor Range PN-B-04481:1988","parameters_zh":[{"name":"范围","range":"(0,70 – 3,50) g/cm3"}],"search_zh":"土体 范围 PN-B-04481:1988","test_object_zh":"土体"},{"_id":"6a5dc9b1f1c10c8ce825bc19","lab_id":"69ad52a3de79e566650fb21b","country":"PL","accr_number":"AB 421","accr_body":"PCA","test_object":"Grunty","test_object_en":"Ground","methodology":"Stopień zagęszczenia ID","methodology_en":"Density index ID","parameters":[{"name":"ID","range":"(0,1 - 1,0)"}],"parameters_en":[{"name":"ID","range":"(0,1 - 1,0)"}],"technique":"Metoda sondą dynamiczną DPL","techniques":["Metoda sondą dynamiczną DPL"],"technique_en":"Dynamic probe method DPL","computed":[],"computed_en":[],"activity":"Stopień zagęszczenia ID\nID (0,1 - 1,0)\nMetoda sondą dynamiczną DPL","reference":"PN-B-04452:2002","norm_bases":["PN-B-04452:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Grunty Stopień zagęszczenia ID\nID (0,1 - 1,0)\nMetoda sondą dynamiczną DPL PN-B-04452:2002 Grunty Stopien zageszczenia ID\nID (0,1 - 1,0)\nMetoda sonda dynamiczna DPL PN-B-04452:2002","categories":["other"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Ground Density index ID Dynamic probe method DPL ID PN-B-04452:2002","search_zh":"土体 PN-B-04452:2002","test_object_zh":"土体"},{"_id":"6a5dc9b1f1c10c8ce825bc1a","lab_id":"69ad52a3de79e566650fb21b","country":"PL","accr_number":"AB 421","accr_body":"PCA","test_object":"Grunty","test_object_en":"Ground","methodology":"Wskaźnik nośności","methodology_en":"Bearing ratio","parameters":[{"name":"Zakres","range":"(0 – 100) %"}],"parameters_en":[{"name":"Range","range":"(0 – 100) %"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik nośności\nZakres (0 – 100) %","reference":"PN-S-02205:1998 zał. A","norm_bases":["PN-S-02205:1998 zał. A"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Grunty Wskaźnik nośności\nZakres (0 – 100) % PN-S-02205:1998 zał. A Grunty Wskaznik nosnosci\nZakres (0 – 100) % PN-S-02205:1998 zal. A","categories":["other"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Ground Bearing ratio Range PN-S-02205:1998 zał. A","parameters_zh":[{"name":"范围","range":"(0 – 100) %"}],"search_zh":"土体 承载比 范围 PN-S-02205:1998 zał. A","test_object_zh":"土体","methodology_zh":"承载比"},{"_id":"6a5dc9b1f1c10c8ce825bc1b","lab_id":"69ad52a3de79e566650fb21b","country":"PL","accr_number":"AB 421","accr_body":"PCA","test_object":"Grunty","test_object_en":"Ground","methodology":"Wskaźnik piaskowy","methodology_en":"Sand equivalent value","parameters":[{"name":"Zakres","range":"(0 – 4) mm"}],"parameters_en":[{"name":"Range","range":"(0 – 4) mm"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik piaskowy\nZakres (0 – 4) mm","reference":"PN-EN 933-8:2015-07","norm_bases":["PN-EN 933-8:2015-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Grunty Wskaźnik piaskowy\nZakres (0 – 4) mm PN-EN 933-8:2015-07 Grunty Wskaznik piaskowy\nZakres (0 – 4) mm PN-EN 933-8:2015-07","categories":["other"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Ground Sand equivalent value Range PN-EN 933-8:2015-07","parameters_zh":[{"name":"范围","range":"(0 – 4) mm"}],"search_zh":"土体 砂当量 范围 PN-EN 933-8:2015-07","test_object_zh":"土体","methodology_zh":"砂当量"},{"_id":"6a5dc9b1f1c10c8ce825bc1c","lab_id":"69ad52a3de79e566650fb21b","country":"PL","accr_number":"AB 421","accr_body":"PCA","test_object":"Kruszywa","test_object_en":"Aggregates","methodology":"Mrozoodporność","methodology_en":"Frost resistance","parameters":[{"name":"Zakres","range":"(8 – 63) mm"}],"parameters_en":[{"name":"Range","range":"(8 – 63) mm"}],"technique":"Metoda: bezpośrednia","techniques":["Metoda: bezpośrednia"],"technique_en":"Method: direct","computed":[],"computed_en":[],"activity":"Mrozoodporność\nZakres (8 – 63) mm\nMetoda: bezpośrednia","reference":"PN-B-06714-19:1978","norm_bases":["PN-B-06714-19:1978"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywa Mrozoodporność\nZakres (8 – 63) mm\nMetoda: bezpośrednia PN-B-06714-19:1978 Kruszywa Mrozoodpornosc\nZakres (8 – 63) mm\nMetoda: bezposrednia PN-B-06714-19:1978","categories":["other"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Aggregates Frost resistance Method: direct Range PN-B-06714-19:1978","parameters_zh":[{"name":"范围","range":"(8 – 63) mm"}],"search_zh":"骨料 抗冻性 方法：直接法 范围 PN-B-06714-19:1978","test_object_zh":"骨料","methodology_zh":"抗冻性","technique_zh":"方法：直接法"},{"_id":"6a5dc9b1f1c10c8ce825bc1d","lab_id":"69ad52a3de79e566650fb21b","country":"PL","accr_number":"AB 421","accr_body":"PCA","test_object":"Kruszywa","test_object_en":"Aggregates","methodology":"Wskaźnik płaskości","methodology_en":"Flakiness index","parameters":[{"name":"Zakres","range":"(1 – 30) %"}],"parameters_en":[{"name":"Range","range":"(1 – 30) %"}],"technique":"Metoda: sit prętowych","techniques":["Metoda: sit prętowych"],"technique_en":"Method: bar sieves","computed":[],"computed_en":[],"activity":"Wskaźnik płaskości\nZakres (1 – 30) %\nMetoda: sit prętowych","reference":"PN-EN 933-3:2012","norm_bases":["PN-EN 933-3:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywa Wskaźnik płaskości\nZakres (1 – 30) %\nMetoda: sit prętowych PN-EN 933-3:2012 Kruszywa Wskaznik plaskosci\nZakres (1 – 30) %\nMetoda: sit pretowych PN-EN 933-3:2012","categories":["other"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Aggregates Flakiness index Method: bar sieves Range PN-EN 933-3:2012","parameters_zh":[{"name":"范围","range":"(1 – 30) %"}],"search_zh":"骨料 片状指数 范围 PN-EN 933-3:2012","test_object_zh":"骨料","methodology_zh":"片状指数"},{"_id":"6a5dc9b1f1c10c8ce825bc1e","lab_id":"69ad52a3de79e566650fb21b","country":"PL","accr_number":"AB 421","accr_body":"PCA","test_object":"Kruszywa","test_object_en":"Aggregates","methodology":"Wskaźnik kształtu","methodology_en":"Shape index","parameters":[{"name":"Zakres","range":"(4 – 80) mm"}],"parameters_en":[{"name":"Range","range":"(4 – 80) mm"}],"technique":"Metoda: suwmiarką Schulza","techniques":["Metoda: suwmiarką Schulza"],"technique_en":"Method: with the Schulz calliper","computed":[],"computed_en":[],"activity":"Wskaźnik kształtu\nZakres (4 – 80) mm\nMetoda: suwmiarką Schulza","reference":"PN-EN 933-4:2008","norm_bases":["PN-EN 933-4:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywa Wskaźnik kształtu\nZakres (4 – 80) mm\nMetoda: suwmiarką Schulza PN-EN 933-4:2008 Kruszywa Wskaznik ksztaltu\nZakres (4 – 80) mm\nMetoda: suwmiarka Schulza PN-EN 933-4:2008","categories":["other"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Aggregates Shape index Method: with the Schulz calliper Range PN-EN 933-4:2008","parameters_zh":[{"name":"范围","range":"(4 – 80) mm"}],"search_zh":"骨料 形状指数 范围 PN-EN 933-4:2008","test_object_zh":"骨料","methodology_zh":"形状指数"},{"_id":"6a5dc9b1f1c10c8ce825bc1f","lab_id":"69ad52a3de79e566650fb21b","country":"PL","accr_number":"AB 421","accr_body":"PCA","test_object":"Kruszywa","test_object_en":"Aggregates","methodology":"Odporność na rozdrabnianie","methodology_en":"Resistance to fragmentation","parameters":[{"name":"Zakres","range":"(4 – 50) mm"}],"parameters_en":[{"name":"Range","range":"(4 – 50) mm"}],"technique":"Metoda Los Angeles","techniques":["Metoda Los Angeles"],"technique_en":"Los Angeles method","computed":[],"computed_en":[],"activity":"Odporność na rozdrabnianie\nZakres (4 – 50) mm\nMetoda Los Angeles","reference":"PN-EN 1097-2:2020-09","norm_bases":["PN-EN 1097-2:2020-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywa Odporność na rozdrabnianie\nZakres (4 – 50) mm\nMetoda Los Angeles PN-EN 1097-2:2020-09 Kruszywa Odpornosc na rozdrabnianie\nZakres (4 – 50) mm\nMetoda Los Angeles PN-EN 1097-2:2020-09","categories":["other"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Aggregates Resistance to fragmentation Los Angeles method Range PN-EN 1097-2:2020-09","parameters_zh":[{"name":"范围","range":"(4 – 50) mm"}],"search_zh":"骨料 抗破碎性 洛杉矶法 范围 PN-EN 1097-2:2020-09","test_object_zh":"骨料","methodology_zh":"抗破碎性","technique_zh":"洛杉矶法"},{"_id":"6a5dc9b1f1c10c8ce825bc20","lab_id":"69ad52a3de79e566650fb21b","country":"PL","accr_number":"AB 421","accr_body":"PCA","test_object":"Kruszywa","test_object_en":"Aggregates","methodology":"Odporność na ścieranie","methodology_en":"Abrasion resistance","parameters":[],"parameters_en":[],"technique":"Metoda mikro Deval","techniques":["Metoda mikro Deval"],"technique_en":"Micro-Deval method","computed":[],"computed_en":[],"activity":"Odporność na ścieranie\nMetoda mikro Deval","reference":"PN-EN 1097-1:2011","norm_bases":["PN-EN 1097-1:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywa Odporność na ścieranie\nMetoda mikro Deval PN-EN 1097-1:2011 Kruszywa Odpornosc na scieranie\nMetoda mikro Deval PN-EN 1097-1:2011","categories":["other"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Aggregates Abrasion resistance Micro-Deval method PN-EN 1097-1:2011","search_zh":"骨料 耐磨性 PN-EN 1097-1:2011","test_object_zh":"骨料","methodology_zh":"耐磨性"},{"_id":"6a5dc9b1f1c10c8ce825bc21","lab_id":"69ad52a3de79e566650fb21b","country":"PL","accr_number":"AB 421","accr_body":"PCA","test_object":"Kruszywa","test_object_en":"Aggregates","methodology":"Skład ziarnowy","methodology_en":"Particle size distribution","parameters":[{"name":"Zakres","range":"(0-63) mm"}],"parameters_en":[{"name":"Range","range":"(0-63) mm"}],"technique":"Metoda przesiewania","techniques":["Metoda przesiewania"],"technique_en":"Sieving method","computed":[],"computed_en":[],"activity":"Skład ziarnowy\nZakres (0-63) mm\nMetoda przesiewania","reference":"PN-EN 933-1:2012","norm_bases":["PN-EN 933-1:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kruszywa Skład ziarnowy\nZakres (0-63) mm\nMetoda przesiewania PN-EN 933-1:2012 Kruszywa Sklad ziarnowy\nZakres (0-63) mm\nMetoda przesiewania PN-EN 933-1:2012","categories":["other"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Aggregates Particle size distribution Sieving method Range PN-EN 933-1:2012","parameters_zh":[{"name":"范围","range":"(0-63) mm"}],"search_zh":"骨料 粒度分布 筛分法 范围 PN-EN 933-1:2012","test_object_zh":"骨料","methodology_zh":"粒度分布","technique_zh":"筛分法"},{"_id":"6a5dc9b1f1c10c8ce825bc22","lab_id":"69ad52a3de79e566650fb21b","country":"PL","accr_number":"AB 421","accr_body":"PCA","test_object":"Warstwy konstrukcyjne nawierzchni","test_object_en":"Pavement structural layers","methodology":"Moduł odkształcenia","methodology_en":"Deformation modulus","parameters":[{"name":"Zakres obciążenia","range":"(0,02 – 0,45) MPa"}],"parameters_en":[{"name":"Load range","range":"(0,02 – 0,45) MPa"}],"technique":"Metoda obciążeń płytą VSS","techniques":["Metoda obciążeń płytą VSS"],"technique_en":"VSS plate loading method","computed":[],"computed_en":[],"activity":"Moduł odkształcenia\nZakres obciążenia (0,02 – 0,45) MPa\nMetoda obciążeń płytą VSS","reference":"Id-3:2009 zał. 2","norm_bases":["Id-3:2009 zał. 2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Warstwy konstrukcyjne nawierzchni Moduł odkształcenia\nZakres obciążenia (0,02 – 0,45) MPa\nMetoda obciążeń płytą VSS Id-3:2009 zał. 2 Warstwy konstrukcyjne nawierzchni Modul odksztalcenia\nZakres obciazenia (0,02 – 0,45) MPa\nMetoda obciazen plyta VSS Id-3:2009 zal. 2","categories":["other"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Pavement structural layers Deformation modulus VSS plate loading method Load range Id-3:2009 zał. 2","search_zh":"路面结构层 变形模量 VSS 平板荷载法 载荷范围 Id-3:2009 zał. 2","test_object_zh":"路面结构层","methodology_zh":"变形模量","technique_zh":"VSS 平板荷载法","parameters_zh":[{"name":"载荷范围","range":"(0,02 – 0,45) MPa"}]},{"_id":"6a5dc9b1f1c10c8ce825bc23","lab_id":"69ad52a3de79e566650fb21b","country":"PL","accr_number":"AB 421","accr_body":"PCA","test_object":"Podłoże","test_object_en":"Growing medium","methodology":"Moduł odkształcenia","methodology_en":"Deformation modulus","parameters":[{"name":"Zakres obciążenia","range":"(0,02 – 0,35) MPa"}],"parameters_en":[{"name":"Load range","range":"(0,02 – 0,35) MPa"}],"technique":"Metoda obciążeń płytą VSS","techniques":["Metoda obciążeń płytą VSS"],"technique_en":"VSS plate loading method","computed":[],"computed_en":[],"activity":"Moduł odkształcenia\nZakres obciążenia (0,02 – 0,35) MPa\nMetoda obciążeń płytą VSS","reference":"PN-S-02205:1998 zał. B","norm_bases":["PN-S-02205:1998 zał. B"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Podłoże Moduł odkształcenia\nZakres obciążenia (0,02 – 0,35) MPa\nMetoda obciążeń płytą VSS PN-S-02205:1998 zał. B Podloze Modul odksztalcenia\nZakres obciazenia (0,02 – 0,35) MPa\nMetoda obciazen plyta VSS PN-S-02205:1998 zal. B","categories":["other"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Growing medium Deformation modulus VSS plate loading method Load range PN-S-02205:1998 zał. B","search_zh":"栽培基质 变形模量 VSS 平板荷载法 载荷范围 PN-S-02205:1998 zał. B","test_object_zh":"栽培基质","methodology_zh":"变形模量","technique_zh":"VSS 平板荷载法","parameters_zh":[{"name":"载荷范围","range":"(0,02 – 0,35) MPa"}]},{"_id":"6a5dc9b1f1c10c8ce825bc24","lab_id":"69ad52a3de79e566650fb21b","country":"PL","accr_number":"AB 421","accr_body":"PCA","test_object":"Izolacje przeciwwodne","test_object_en":"Waterproofing","methodology":"Maksymalna siła rozciągająca","methodology_en":"Maximum tensile force","parameters":[{"name":"Zakres siły","range":"(0,1 – 10) kN"}],"parameters_en":[{"name":"Force range","range":"(0,1 – 10) kN"}],"technique":"Metoda: rozciągania bezpośredniego","techniques":["Metoda: rozciągania bezpośredniego"],"technique_en":"Method: direct tension","computed":[],"computed_en":[],"activity":"Maksymalna siła rozciągająca\nZakres siły (0,1 – 10) kN\nMetoda: rozciągania bezpośredniego","reference":"PN-EN 12311-1:2001","norm_bases":["PN-EN 12311-1:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Izolacje przeciwwodne Maksymalna siła rozciągająca\nZakres siły (0,1 – 10) kN\nMetoda: rozciągania bezpośredniego PN-EN 12311-1:2001 Izolacje przeciwwodne Maksymalna sila rozciagajaca\nZakres sily (0,1 – 10) kN\nMetoda: rozciagania bezposredniego PN-EN 12311-1:2001","categories":["construction"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waterproofing Maximum tensile force Method: direct tension Force range PN-EN 12311-1:2001","parameters_zh":[{"name":"力值范围","range":"(0,1 – 10) kN"}],"search_zh":"防水隔离层 方法：直接拉伸 力值范围 PN-EN 12311-1:2001","test_object_zh":"防水隔离层","technique_zh":"方法：直接拉伸"},{"_id":"6a5dc9b1f1c10c8ce825bc25","lab_id":"69ad52a3de79e566650fb21b","country":"PL","accr_number":"AB 421","accr_body":"PCA","test_object":"Izolacje przeciwwodne","test_object_en":"Waterproofing","methodology":"Wydłużenie przy maksymalnej sile rozciągającej","methodology_en":"Elongation at maximum tensile force","parameters":[{"name":"Zakres siły","range":"(0,1 – 10) kN"}],"parameters_en":[{"name":"Force range","range":"(0,1 – 10) kN"}],"technique":"Metoda: rozciągania bezpośredniego","techniques":["Metoda: rozciągania bezpośredniego"],"technique_en":"Method: direct tension","computed":[],"computed_en":[],"activity":"Wydłużenie przy maksymalnej sile rozciągającej\nZakres siły (0,1 – 10) kN\nMetoda: rozciągania bezpośredniego","reference":"PN-EN 12311-1:2001","norm_bases":["PN-EN 12311-1:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Izolacje przeciwwodne Wydłużenie przy maksymalnej sile rozciągającej\nZakres siły (0,1 – 10) kN\nMetoda: rozciągania bezpośredniego PN-EN 12311-1:2001 Izolacje przeciwwodne Wydluzenie przy maksymalnej sile rozciagajacej\nZakres sily (0,1 – 10) kN\nMetoda: rozciagania bezposredniego PN-EN 12311-1:2001","categories":["construction"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waterproofing Elongation at maximum tensile force Method: direct tension Force range PN-EN 12311-1:2001","parameters_zh":[{"name":"力值范围","range":"(0,1 – 10) kN"}],"search_zh":"防水隔离层 方法：直接拉伸 力值范围 PN-EN 12311-1:2001","test_object_zh":"防水隔离层","technique_zh":"方法：直接拉伸"},{"_id":"6a5dc9b1f1c10c8ce825bc26","lab_id":"69ad52a3de79e566650fb21b","country":"PL","accr_number":"AB 421","accr_body":"PCA","test_object":"Izolacje przeciwwodne","test_object_en":"Waterproofing","methodology":"Siła zrywająca przy rozdzieraniu","methodology_en":"Breaking force in tearing","parameters":[{"name":"Zakres siły","range":"(0,1 – 10) kN"}],"parameters_en":[{"name":"Force range","range":"(0,1 – 10) kN"}],"technique":"Metoda: rozciągania bezpośredniego","techniques":["Metoda: rozciągania bezpośredniego"],"technique_en":"Method: direct tension","computed":[],"computed_en":[],"activity":"Siła zrywająca przy rozdzieraniu\nZakres siły (0,1 – 10) kN\nMetoda: rozciągania bezpośredniego","reference":"PB/TM-1/4:2013 wyd. 4 z dnia 12.12.2013 r.","norm_bases":["PB/TM-1/4:2013 wyd. 4 z dnia 12.12.2013 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Izolacje przeciwwodne Siła zrywająca przy rozdzieraniu\nZakres siły (0,1 – 10) kN\nMetoda: rozciągania bezpośredniego PB/TM-1/4:2013 wyd. 4 z dnia 12.12.2013 r. Izolacje przeciwwodne Sila zrywajaca przy rozdzieraniu\nZakres sily (0,1 – 10) kN\nMetoda: rozciagania bezposredniego PB/TM-1/4:2013 wyd. 4 z dnia 12.12.2013 r.","categories":["construction"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waterproofing Breaking force in tearing Method: direct tension Force range PB/TM-1/4:2013 wyd. 4 z dnia 12.12.2013 r.","parameters_zh":[{"name":"力值范围","range":"(0,1 – 10) kN"}],"search_zh":"防水隔离层 方法：直接拉伸 力值范围 PB/TM-1/4:2013 wyd. 4 z dnia 12.12.2013 r.","test_object_zh":"防水隔离层","technique_zh":"方法：直接拉伸"},{"_id":"6a5dc9b1f1c10c8ce825bc27","lab_id":"69ad52a3de79e566650fb21b","country":"PL","accr_number":"AB 421","accr_body":"PCA","test_object":"Izolacje przeciwwodne","test_object_en":"Waterproofing","methodology":"Wytrzymałość na ścinanie styków arkuszy papy","methodology_en":"Shear strength of joints of bituminous membrane sheets","parameters":[{"name":"Zakres siły","range":"(0,1 – 10) kN"}],"parameters_en":[{"name":"Force range","range":"(0,1 – 10) kN"}],"technique":"Metoda: rozciągania bezpośredniego","techniques":["Metoda: rozciągania bezpośredniego"],"technique_en":"Method: direct tension","computed":[],"computed_en":[],"activity":"Wytrzymałość na ścinanie styków arkuszy papy\nZakres siły (0,1 – 10) kN\nMetoda: rozciągania bezpośredniego","reference":"PB/TM-1/9:2013 wyd. 4 z dnia 12.12.2013 r.","norm_bases":["PB/TM-1/9:2013 wyd. 4 z dnia 12.12.2013 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Izolacje przeciwwodne Wytrzymałość na ścinanie styków arkuszy papy\nZakres siły (0,1 – 10) kN\nMetoda: rozciągania bezpośredniego PB/TM-1/9:2013 wyd. 4 z dnia 12.12.2013 r. Izolacje przeciwwodne Wytrzymalosc na scinanie stykow arkuszy papy\nZakres sily (0,1 – 10) kN\nMetoda: rozciagania bezposredniego PB/TM-1/9:2013 wyd. 4 z dnia 12.12.2013 r.","categories":["construction"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waterproofing Shear strength of joints of bituminous membrane sheets Method: direct tension Force range PB/TM-1/9:2013 wyd. 4 z dnia 12.12.2013 r.","parameters_zh":[{"name":"力值范围","range":"(0,1 – 10) kN"}],"search_zh":"防水隔离层 方法：直接拉伸 力值范围 PB/TM-1/9:2013 wyd. 4 z dnia 12.12.2013 r.","test_object_zh":"防水隔离层","technique_zh":"方法：直接拉伸"},{"_id":"6a5dc9b1f1c10c8ce825bc28","lab_id":"69ad52a3de79e566650fb21b","country":"PL","accr_number":"AB 421","accr_body":"PCA","test_object":"Pale","test_object_en":"Piles","methodology":"Nośność","methodology_en":"Load-bearing capacity","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Nośność","reference":"PB/TF-1/1 wydanie 7 z dnia 10.07.2017 r. | PN-83/B-02482","norm_bases":["PB/TF-1/1 wydanie 7 z dnia 10.07.2017 r.","PN-83/B-02482"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pale Nośność PB/TF-1/1 wydanie 7 z dnia 10.07.2017 r. | PN-83/B-02482 Pale Nosnosc PB/TF-1/1 wydanie 7 z dnia 10.07.2017 r. | PN-83/B-02482","categories":["other"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Piles Load-bearing capacity PB/TF-1/1 wydanie 7 z dnia 10.07.2017 r. | PN-83/B-02482","methodology_zh":"承载力","search_zh":"承载力 PB/TF-1/1 wydanie 7 z dnia 10.07.2017 r. | PN-83/B-02482"},{"_id":"6a5dc9b1f1c10c8ce825bc29","lab_id":"69ad52a3de79e566650fb21b","country":"PL","accr_number":"AB 421","accr_body":"PCA","test_object":"Pale żelbetowe","test_object_en":"Reinforced concrete piles","methodology":"Ciągłość trzonu","methodology_en":"Continuity of the shank","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Ciągłość trzonu","reference":"PB/TF-1/2 wydanie 5 z dnia 10.07.2017 r.","norm_bases":["PB/TF-1/2 wydanie 5 z dnia 10.07.2017 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pale żelbetowe Ciągłość trzonu PB/TF-1/2 wydanie 5 z dnia 10.07.2017 r. Pale zelbetowe Ciaglosc trzonu PB/TF-1/2 wydanie 5 z dnia 10.07.2017 r.","categories":["other"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Reinforced concrete piles Continuity of the shank PB/TF-1/2 wydanie 5 z dnia 10.07.2017 r."}],"has_pdf":true}