{"lab":{"_id":"69ad52a3de79e566650fb213","accr_number":"AB 415","country":"PL","accr_body":"PCA","address":"ul. Młynowa 52/1, 15-404 Białystok","categories":["water","microbiology"],"city":"Białystok","imported_at":"2026-03-08T10:42:43.265Z","methods_count":80,"name":"WODOCIĄGI BIAŁOSTOCKIE Sp. z o. o.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_415.pdf"],"scope_summary":"","search_text":"wodociągi białostockie sp. z o. o. ul. młynowa 52/1, 15-404 białystok water other pharma electronics microbiology materials automotive","status":"active","updated_at":"2026-03-08T14:51:15.084Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:15.084Z","location":{"type":"Point","coordinates":[23.1688,53.1325]},"email_confidence":"high","email_mx":true,"email_source":"https://bip.wobi.pl/artykul/41/26/dane-podstawowe","fields_of_testing":[{"codes":"C/28/P; C/29/P; C/30/P; C/32/P","pl":"Badania chemiczne i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków, osadów ściekowych","en":"Chemical tests and sampling of water, drinking water, sewage, sediments"},{"codes":"B/32/P","pl":"Badania biologiczne i pobieranie próbek osadów ściekowych","en":"Biological tests and sampling of sewage"},{"codes":"K/29/P; K/32/P","pl":"Badania mikrobiologiczne i pobieranie próbek wody do spożycia przez ludzi, osadów ściekowych","en":"Microbiological tests and sampling of drinking water, sediments"},{"codes":"N/28/P; N/29/P; N/30/P; N/32/P","pl":"Badanie właściwości fizycznych i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków, osadów ściekowych","en":"Tests of physical properties and sampling of water, drinking water, sewage, sediments"},{"codes":"Q/29/P","pl":"Badania sensoryczne i pobieranie próbek wody do spożycia przez ludzi","en":"Sensory tests and sampling of drinking water"}],"issue":{"no":"21","date":"27.11.2025"},"parse_date":"2026-07-20T07:09:37.723Z","parse_source":"script-pdfplumber","map_coord":[53.128202,23.146883],"map_geo":"nominatim-street","has_en":true,"category_counts":{"water":80,"microbiology":7,"materials":4},"category_scores":{"water":70.33,"microbiology":0.54,"materials":0.18},"has_zh":true},"methods":[{"_id":"6a5dc9b1f1c10c8ce825bbb6","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Pobieranie próbek wody do badań chemicznych i fizycznych (w tym sensorycznych)","methodology_en":"Water sampling for chemical and physical testing (including sensory)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek wody do badań chemicznych i fizycznych (w tym sensorycznych)","reference":"PN-ISO 5667-5:2017-10","norm_bases":["PN-ISO 5667-5:2017-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek wody do badań chemicznych i fizycznych (w tym sensorycznych) PN-ISO 5667-5:2017-10 Woda do spozycia przez ludzi Pobieranie probek wody do badan chemicznych i fizycznych (w tym sensorycznych) PN-ISO 5667-5:2017-10","categories":["water"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Water sampling for chemical and physical testing (including sensory) PN-ISO 5667-5:2017-10","search_zh":"生活饮用水 PN-ISO 5667-5:2017-10","test_object_zh":"生活饮用水"},{"_id":"6a5dc9b1f1c10c8ce825bbb7","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Pobieranie próbek wody do badań mikrobiologicznych","methodology_en":"Water sampling for microbiological testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek wody do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007 z wył. pkt. 4.4.3, 4.4.4, 4.4.5, 4.4.6","norm_bases":["PN-EN ISO 19458:2007 z wył. pkt. 4.4.3, 4.4.4, 4.4.5, 4.4.6"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek wody do badań mikrobiologicznych PN-EN ISO 19458:2007 z wył. pkt. 4.4.3, 4.4.4, 4.4.5, 4.4.6 Woda do spozycia przez ludzi Pobieranie probek wody do badan mikrobiologicznych PN-EN ISO 19458:2007 z wyl. pkt. 4.4.3, 4.4.4, 4.4.5, 4.4.6","categories":["water","microbiology"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Water sampling for microbiological testing PN-EN ISO 19458:2007 z wył. pkt. 4.4.3, 4.4.4, 4.4.5, 4.4.6","search_zh":"生活饮用水 用于微生物检验的水样采集 PN-EN ISO 19458:2007 z wył. pkt. 4.4.3, 4.4.4, 4.4.5, 4.4.6","test_object_zh":"生活饮用水","methodology_zh":"用于微生物检验的水样采集"},{"_id":"6a5dc9b1f1c10c8ce825bbb8","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie chloru wolnego ☑","methodology_en":"Free chlorine concentration ☑","parameters":[{"name":"Zakres","range":"(0,08 – 2,00) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,08 – 2,00) mg/l"}],"technique":"Metoda fotometryczna","techniques":["Metoda fotometryczna"],"technique_en":"Photometric method","computed":[],"computed_en":[],"activity":"Stężenie chloru wolnego ☑\nZakres (0,08 – 2,00) mg/l\nMetoda fotometryczna","reference":"HACH Metoda 8021","norm_bases":["HACH Metoda 8021"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie chloru wolnego ☑\nZakres (0,08 – 2,00) mg/l\nMetoda fotometryczna HACH Metoda 8021 Woda do spozycia przez ludzi Stezenie chloru wolnego ☑\nZakres (0,08 – 2,00) mg/l\nMetoda fotometryczna HACH Metoda 8021","categories":["water"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Free chlorine concentration ☑ Photometric method Range HACH Metoda 8021","parameters_zh":[{"name":"范围","range":"(0,08 – 2,00) mg/l"}],"search_zh":"生活饮用水 游离氯浓度 ☑ 光度法 范围 HACH Metoda 8021","test_object_zh":"生活饮用水","technique_zh":"光度法","methodology_zh":"游离氯浓度 ☑"},{"_id":"6a5dc9b1f1c10c8ce825bbb9","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie azotanów","methodology_en":"Nitrate concentration","parameters":[{"name":"Zakres","range":"(1,2 – 200,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(1,2 – 200,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotanów\nZakres (1,2 – 200,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie azotanów\nZakres (1,2 – 200,0) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08 Woda do spozycia przez ludzi Stezenie azotanow\nZakres (1,2 – 200,0) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Nitrate concentration Spectrophotometric method Range PN-82/C-04576/08","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(1,2 – 200,0) mg/l"}],"search_zh":"生活饮用水 硝酸盐浓度 分光光度法 范围 PN-82/C-04576/08","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9b1f1c10c8ce825bbba","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie azotynów","methodology_en":"Nitrite concentration","parameters":[{"name":"Zakres","range":"(0,03 – 2,00) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,03 – 2,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotynów\nZakres (0,03 – 2,00) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie azotynów\nZakres (0,03 – 2,00) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda do spozycia przez ludzi Stezenie azotynow\nZakres (0,03 – 2,00) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Nitrite concentration Spectrophotometric method Range PN-EN 26777:1999","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,03 – 2,00) mg/l"}],"search_zh":"生活饮用水 亚硝酸盐浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9b1f1c10c8ce825bbbb","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Barwa","methodology_en":"Colour","parameters":[{"name":"Zakres","range":"(5 – 350) mg/l Pt"}],"parameters_en":[{"name":"Range","range":"(5 – 350) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Barwa\nZakres (5 – 350) mg/l Pt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012 Metoda C","norm_bases":["PN-EN ISO 7887:2012 Metoda C"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Barwa\nZakres (5 – 350) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 Metoda C Woda do spozycia przez ludzi Barwa\nZakres (5 – 350) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 Metoda C","categories":["water"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Colour Spectrophotometric method Range PN-EN ISO 7887:2012 Metoda C","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(5 – 350) mg/l Pt"}],"search_zh":"生活饮用水 色度 分光光度法 范围 PN-EN ISO 7887:2012 Metoda C","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9b1f1c10c8ce825bbbc","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie boru","methodology_en":"Boron concentration","parameters":[{"name":"Zakres","range":"(0,2 – 1,5) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,2 – 1,5) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie boru\nZakres (0,2 – 1,5) mg/l\nMetoda spektrofotometryczna","reference":"Merck Test nr 1.00826.0001","norm_bases":["Merck Test nr 1.00826.0001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie boru\nZakres (0,2 – 1,5) mg/l\nMetoda spektrofotometryczna Merck Test nr 1.00826.0001 Woda do spozycia przez ludzi Stezenie boru\nZakres (0,2 – 1,5) mg/l\nMetoda spektrofotometryczna Merck Test nr 1.00826.0001","categories":["water"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Boron concentration Spectrophotometric method Range Merck Test nr 1.00826.0001","parameters_zh":[{"name":"范围","range":"(0,2 – 1,5) mg/l"}],"search_zh":"生活饮用水 硼浓度 分光光度法 范围 Merck Test nr 1.00826.0001","technique_zh":"分光光度法","test_object_zh":"生活饮用水","methodology_zh":"硼浓度"},{"_id":"6a5dc9b1f1c10c8ce825bbbd","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie bromianów","methodology_en":"Bromate concentration","parameters":[{"name":"Zakres","range":"(2 – 200) μg/l"}],"parameters_en":[{"name":"Range","range":"(2 – 200) μg/l"}],"technique":"Metoda chromatografii jonowej (IC)","techniques":["Metoda chromatografii jonowej (IC)"],"technique_en":"Ion chromatography (IC)","computed":[],"computed_en":[],"activity":"Stężenie bromianów\nZakres (2 – 200) μg/l\nMetoda chromatografii jonowej (IC)","reference":"PN-EN ISO 15061:2003","norm_bases":["PN-EN ISO 15061:2003"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie bromianów\nZakres (2 – 200) μg/l\nMetoda chromatografii jonowej (IC) PN-EN ISO 15061:2003 Woda do spozycia przez ludzi Stezenie bromianow\nZakres (2 – 200) μg/l\nMetoda chromatografii jonowej (IC) PN-EN ISO 15061:2003","categories":["water"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Bromate concentration Ion chromatography (IC) Range PN-EN ISO 15061:2003","parameters_zh":[{"name":"范围","range":"(2 – 200) μg/l"}],"search_zh":"生活饮用水 溴酸盐浓度 离子色谱法（IC） 范围 PN-EN ISO 15061:2003","test_object_zh":"生活饮用水","technique_zh":"离子色谱法（IC）","methodology_zh":"溴酸盐浓度"},{"_id":"6a5dc9b1f1c10c8ce825bbbe","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie chlorków","methodology_en":"Chloride concentration","parameters":[{"name":"Zakres","range":"(5,00 – 400) mg/l"}],"parameters_en":[{"name":"Range","range":"(5,00 – 400) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie chlorków\nZakres (5,00 – 400) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie chlorków\nZakres (5,00 – 400) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda do spozycia przez ludzi Stezenie chlorkow\nZakres (5,00 – 400) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Chloride concentration Titrimetric method Range PN-ISO 9297:1994","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,00 – 400) mg/l"}],"search_zh":"生活饮用水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9b1f1c10c8ce825bbbf","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie cyjanków","methodology_en":"Cyanide concentration","parameters":[{"name":"Zakres","range":"(10 – 60) μg/l"}],"parameters_en":[{"name":"Range","range":"(10 – 60) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie cyjanków\nZakres (10 – 60) μg/l\nMetoda spektrofotometryczna","reference":"Merck Test nr 1.09701.0001","norm_bases":["Merck Test nr 1.09701.0001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie cyjanków\nZakres (10 – 60) μg/l\nMetoda spektrofotometryczna Merck Test nr 1.09701.0001 Woda do spozycia przez ludzi Stezenie cyjankow\nZakres (10 – 60) μg/l\nMetoda spektrofotometryczna Merck Test nr 1.09701.0001","categories":["water"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Cyanide concentration Spectrophotometric method Range Merck Test nr 1.09701.0001","parameters_zh":[{"name":"范围","range":"(10 – 60) μg/l"}],"search_zh":"生活饮用水 氰化物浓度 分光光度法 范围 Merck Test nr 1.09701.0001","technique_zh":"分光光度法","test_object_zh":"生活饮用水","methodology_zh":"氰化物浓度"},{"_id":"6a5dc9b1f1c10c8ce825bbc0","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie glinu","methodology_en":"Aluminium concentration","parameters":[{"name":"Zakres","range":"(40 – 400) μg/l"}],"parameters_en":[{"name":"Range","range":"(40 – 400) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie glinu\nZakres (40 – 400) μg/l\nMetoda spektrofotometryczna","reference":"PN-92/C-04605/02","norm_bases":["PN-92/C-04605/02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie glinu\nZakres (40 – 400) μg/l\nMetoda spektrofotometryczna PN-92/C-04605/02 Woda do spozycia przez ludzi Stezenie glinu\nZakres (40 – 400) μg/l\nMetoda spektrofotometryczna PN-92/C-04605/02","categories":["water"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Aluminium concentration Spectrophotometric method Range PN-92/C-04605/02","parameters_zh":[{"name":"范围","range":"(40 – 400) μg/l"}],"search_zh":"生活饮用水 铝浓度 分光光度法 范围 PN-92/C-04605/02","technique_zh":"分光光度法","test_object_zh":"生活饮用水","methodology_zh":"铝浓度"},{"_id":"6a5dc9b1f1c10c8ce825bbc1","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie azotu amonowego (jonu amonu)","methodology_en":"Ammonium nitrogen (ammonium ion) concentration","parameters":[{"name":"Zakres","range":"(0,10 – 10) mg/l NH4"}],"parameters_en":[{"name":"Range","range":"(0,10 – 10) mg/l NH4"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego (jonu amonu)\nZakres (0,10 – 10) mg/l NH4\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie azotu amonowego (jonu amonu)\nZakres (0,10 – 10) mg/l NH4\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda do spozycia przez ludzi Stezenie azotu amonowego (jonu amonu)\nZakres (0,10 – 10) mg/l NH4\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Ammonium nitrogen (ammonium ion) concentration Spectrophotometric method Range PN-ISO 7150-1:2002","parameters_zh":[{"name":"范围","range":"(0,10 – 10) mg/l NH4"}],"search_zh":"生活饮用水 分光光度法 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9b1f1c10c8ce825bbc2","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie magnezu","methodology_en":"Magnesium concentration","parameters":[{"name":"Zakres","range":"(0,050 – 25) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,050 – 25) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"technique_en":"Flame atomic absorption spectrometry (FAAS)","computed":[],"computed_en":[],"activity":"Stężenie magnezu\nZakres (0,050 – 25) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-EN ISO 7980:2002 (tylko dla próbek o zawartości siarczanów < 250 mg/l)","norm_bases":["PN-EN ISO 7980:2002 (tylko dla próbek o zawartości siarczanów < 250 mg/l)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie magnezu\nZakres (0,050 – 25) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN ISO 7980:2002 (tylko dla próbek o zawartości siarczanów < 250 mg/l) Woda do spozycia przez ludzi Stezenie magnezu\nZakres (0,050 – 25) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN ISO 7980:2002 (tylko dla probek o zawartosci siarczanow < 250 mg/l)","categories":["water"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Magnesium concentration Flame atomic absorption spectrometry (FAAS) Range PN-EN ISO 7980:2002 (tylko dla próbek o zawartości siarczanów < 250 mg/l)","parameters_zh":[{"name":"范围","range":"(0,050 – 25) mg/l"}],"search_zh":"生活饮用水 镁浓度 火焰原子吸收光谱法（FAAS） 范围 PN-EN ISO 7980:2002 (tylko dla próbek o zawartości siarczanów < 250 mg/l)","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"生活饮用水","methodology_zh":"镁浓度"},{"_id":"6a5dc9b1f1c10c8ce825bbc3","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie manganu","methodology_en":"Manganese concentration","parameters":[{"name":"Zakres","range":"(15 – 600) μg/l"}],"parameters_en":[{"name":"Range","range":"(15 – 600) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie manganu\nZakres (15 – 600) μg/l\nMetoda spektrofotometryczna","reference":"PN-92/C-04590/03 tylko dla próbek o zawartości żelaza ogólnego < 500 μg/L","norm_bases":["PN-92/C-04590/03 tylko dla próbek o zawartości żelaza ogólnego < 500 μg/L"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie manganu\nZakres (15 – 600) μg/l\nMetoda spektrofotometryczna PN-92/C-04590/03 tylko dla próbek o zawartości żelaza ogólnego < 500 μg/L Woda do spozycia przez ludzi Stezenie manganu\nZakres (15 – 600) μg/l\nMetoda spektrofotometryczna PN-92/C-04590/03 tylko dla probek o zawartosci zelaza ogolnego < 500 μg/L","categories":["water"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Manganese concentration Spectrophotometric method Range PN-92/C-04590/03 tylko dla próbek o zawartości żelaza ogólnego < 500 μg/L","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(15 – 600) μg/l"}],"search_zh":"生活饮用水 锰浓度 分光光度法 范围 PN-92/C-04590/03 tylko dla próbek o zawartości żelaza ogólnego < 500 μg/L","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9b1f1c10c8ce825bbc4","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Mętność","methodology_en":"Turbidity","parameters":[{"name":"Zakres","range":"(0,20-100) NTU"}],"parameters_en":[{"name":"Range","range":"(0,20-100) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"technique_en":"Nephelometric method","computed":[],"computed_en":[],"activity":"Mętność\nZakres (0,20-100) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09 z wyłączeniem pkt 5.4","norm_bases":["PN-EN ISO 7027-1:2016-09 z wyłączeniem pkt 5.4"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Mętność\nZakres (0,20-100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 z wyłączeniem pkt 5.4 Woda do spozycia przez ludzi Metnosc\nZakres (0,20-100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 z wylaczeniem pkt 5.4","categories":["water"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09 z wyłączeniem pkt 5.4","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,20-100) NTU"}],"search_zh":"生活饮用水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09 z wyłączeniem pkt 5.4","technique_zh":"浊度法（散射法）","test_object_zh":"生活饮用水"},{"_id":"6a5dc9b1f1c10c8ce825bbc5","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie miedzi","methodology_en":"Copper concentration","parameters":[{"name":"Zakres","range":"(0,10 – 5,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,10 – 5,0) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"technique_en":"Flame atomic absorption spectrometry (FAAS)","computed":[],"computed_en":[],"activity":"Stężenie miedzi\nZakres (0,10 – 5,0) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-EN ISO 8288:2002 Metoda A","norm_bases":["PN-EN ISO 8288:2002 Metoda A"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie miedzi\nZakres (0,10 – 5,0) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN ISO 8288:2002 Metoda A Woda do spozycia przez ludzi Stezenie miedzi\nZakres (0,10 – 5,0) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN ISO 8288:2002 Metoda A","categories":["water"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Copper concentration Flame atomic absorption spectrometry (FAAS) Range PN-EN ISO 8288:2002 Metoda A","parameters_zh":[{"name":"范围","range":"(0,10 – 5,0) mg/l"}],"search_zh":"生活饮用水 铜浓度 火焰原子吸收光谱法（FAAS） 范围 PN-EN ISO 8288:2002 Metoda A","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"生活饮用水","methodology_zh":"铜浓度"},{"_id":"6a5dc9b1f1c10c8ce825bbc6","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie ogólnego węgla organicznego (OWO)","methodology_en":"Total organic carbon concentration (TOC)","parameters":[{"name":"Zakres","range":"(1,0 – 20) mg/l"}],"parameters_en":[{"name":"Range","range":"(1,0 – 20) mg/l"}],"technique":"Metoda spektrometrii w zakresie podczerwieni IR","techniques":["Metoda spektrometrii w zakresie podczerwieni IR"],"technique_en":"Spectrometry method in the infrared range IR","computed":[],"computed_en":[],"activity":"Stężenie ogólnego węgla organicznego (OWO)\nZakres (1,0 – 20) mg/l\nMetoda spektrometrii w zakresie podczerwieni IR","reference":"PN-EN 1484:1999","norm_bases":["PN-EN 1484:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie ogólnego węgla organicznego (OWO)\nZakres (1,0 – 20) mg/l\nMetoda spektrometrii w zakresie podczerwieni IR PN-EN 1484:1999 Woda do spozycia przez ludzi Stezenie ogolnego wegla organicznego (OWO)\nZakres (1,0 – 20) mg/l\nMetoda spektrometrii w zakresie podczerwieni IR PN-EN 1484:1999","categories":["water"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Total organic carbon concentration (TOC) Spectrometry method in the infrared range IR Range PN-EN 1484:1999","parameters_zh":[{"name":"范围","range":"(1,0 – 20) mg/l"}],"search_zh":"生活饮用水 总有机碳浓度（TOC） 红外光谱法 IR 范围 PN-EN 1484:1999","test_object_zh":"生活饮用水","methodology_zh":"总有机碳浓度（TOC）","technique_zh":"红外光谱法 IR"},{"_id":"6a5dc9b1f1c10c8ce825bbc7","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Przewodność elektryczna","methodology_en":"Electrical conductivity","parameters":[{"name":"Zakres","range":"(100-3000) μS/cm"}],"parameters_en":[{"name":"Range","range":"(100-3000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"technique_en":"Conductometric method","computed":[],"computed_en":[],"activity":"Przewodność elektryczna\nZakres (100-3000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Przewodność elektryczna\nZakres (100-3000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda do spozycia przez ludzi Przewodnosc elektryczna\nZakres (100-3000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Electrical conductivity Conductometric method Range PN-EN 27888:1999","parameters_zh":[{"name":"范围","range":"(100-3000) μS/cm"}],"search_zh":"生活饮用水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"生活饮用水","methodology_zh":"电导率"},{"_id":"6a5dc9b1f1c10c8ce825bbc8","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie sodu","methodology_en":"Sodium concentration","parameters":[{"name":"Zakres","range":"(0,1 – 200,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,1 – 200,0) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"technique_en":"Flame atomic absorption spectrometry (FAAS)","computed":[],"computed_en":[],"activity":"Stężenie sodu\nZakres (0,1 – 200,0) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 9964-1:1994+Ap1:2009","norm_bases":["PN-ISO 9964-1:1994+Ap1:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie sodu\nZakres (0,1 – 200,0) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 9964-1:1994+Ap1:2009 Woda do spozycia przez ludzi Stezenie sodu\nZakres (0,1 – 200,0) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 9964-1:1994+Ap1:2009","categories":["water"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Sodium concentration Flame atomic absorption spectrometry (FAAS) Range PN-ISO 9964-1:1994+Ap1:2009","parameters_zh":[{"name":"范围","range":"(0,1 – 200,0) mg/l"}],"search_zh":"生活饮用水 钠浓度 火焰原子吸收光谱法（FAAS） 范围 PN-ISO 9964-1:1994+Ap1:2009","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"生活饮用水","methodology_zh":"钠浓度"},{"_id":"6a5dc9b1f1c10c8ce825bbc9","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"pH","methodology_en":"pH","parameters":[{"name":"zakres","range":"4,0 – 10,0"}],"parameters_en":[{"name":"range","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nzakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi pH\nzakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda do spozycia przez ludzi pH\nzakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption pH Potentiometric method range PN-EN ISO 10523:2012","methodology_zh":"pH 值","search_zh":"生活饮用水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"生活饮用水","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}]},{"_id":"6a5dc9b1f1c10c8ce825bbca","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)","methodology_en":"Total content of calcium and magnesium (total hardness)","parameters":[{"name":"Zakres","range":"(15 – 700) mg/l CaCO3"}],"parameters_en":[{"name":"Range","range":"(15 – 700) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (15 – 700) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (15 – 700) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999 Woda do spozycia przez ludzi Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna)\nZakres (15 – 700) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Total content of calcium and magnesium (total hardness) Titrimetric method Range PN-ISO 6059:1999","methodology_zh":"钙与镁总量（总硬度）","parameters_zh":[{"name":"范围","range":"(15 – 700) mg/l CaCO3"}],"search_zh":"生活饮用水 钙与镁总量（总硬度） 滴定法 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9b1f1c10c8ce825bbcb","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Indeks nadmanganianowy (utlenialność z KMnO4)","methodology_en":"Permanganate index (oxidisability with KMnO4)","parameters":[{"name":"Zakres","range":"(0,50 – 80) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(0,50 – 80) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Indeks nadmanganianowy (utlenialność z KMnO4)\nZakres (0,50 – 80) mg/l O2\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Indeks nadmanganianowy (utlenialność z KMnO4)\nZakres (0,50 – 80) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda do spozycia przez ludzi Indeks nadmanganianowy (utlenialnosc z KMnO4)\nZakres (0,50 – 80) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":21,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Permanganate index (oxidisability with KMnO4) Titrimetric method Range PN-EN ISO 8467:2001","parameters_zh":[{"name":"范围","range":"(0,50 – 80) mg/l O2"}],"search_zh":"生活饮用水 高锰酸盐指数（KMnO4 耗氧量） 滴定法 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"生活饮用水","methodology_zh":"高锰酸盐指数（KMnO4 耗氧量）"},{"_id":"6a5dc9b1f1c10c8ce825bbcc","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie żelaza","methodology_en":"Iron concentration","parameters":[{"name":"Zakres","range":"(20 – 25000) μg/l"}],"parameters_en":[{"name":"Range","range":"(20 – 25000) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie żelaza\nZakres (20 – 25000) μg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001+Ap1:2016-06","norm_bases":["PN-ISO 6332:2001+Ap1:2016-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie żelaza\nZakres (20 – 25000) μg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06 Woda do spozycia przez ludzi Stezenie zelaza\nZakres (20 – 25000) μg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06","categories":["water"],"row_index":22,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Iron concentration Spectrophotometric method Range PN-ISO 6332:2001+Ap1:2016-06","methodology_zh":"铁浓度","parameters_zh":[{"name":"范围","range":"(20 – 25000) μg/l"}],"search_zh":"生活饮用水 铁浓度 分光光度法 范围 PN-ISO 6332:2001+Ap1:2016-06","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9b1f1c10c8ce825bbcd","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie żelaza","methodology_en":"Iron concentration","parameters":[{"name":"Zakres","range":"(60 – 5000) μg/l"}],"parameters_en":[{"name":"Range","range":"(60 – 5000) μg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"technique_en":"Flame atomic absorption spectrometry (FAAS)","computed":[],"computed_en":[],"activity":"Stężenie żelaza\nZakres (60 – 5000) μg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-92/C-04570/01","norm_bases":["PN-92/C-04570/01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie żelaza\nZakres (60 – 5000) μg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-92/C-04570/01 Woda do spozycia przez ludzi Stezenie zelaza\nZakres (60 – 5000) μg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-92/C-04570/01","categories":["water"],"row_index":23,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Iron concentration Flame atomic absorption spectrometry (FAAS) Range PN-92/C-04570/01","methodology_zh":"铁浓度","parameters_zh":[{"name":"范围","range":"(60 – 5000) μg/l"}],"search_zh":"生活饮用水 铁浓度 火焰原子吸收光谱法（FAAS） 范围 PN-92/C-04570/01","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"生活饮用水"},{"_id":"6a5dc9b1f1c10c8ce825bbce","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie anionów:","methodology_en":"Anion concentrations:","parameters":[{"name":"Azotany","range":"(5,0 – 200) mg/l"},{"name":"Azotyny","range":"(0,050 – 2,0) mg/l"},{"name":"Chlorki","range":"(5,0 – 400) mg/l"},{"name":"Fluorki","range":"(0,15 – 3,0) mg/l"},{"name":"Siarczany","range":"(5,0 – 300) mg/l"}],"parameters_en":[{"name":"Nitrates","range":"(5,0 – 200) mg/l"},{"name":"Nitrites","range":"(0,050 – 2,0) mg/l"},{"name":"Chlorides","range":"(5,0 – 400) mg/l"},{"name":"Fluorides","range":"(0,15 – 3,0) mg/l"},{"name":"Sulfates","range":"(5,0 – 300) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CP)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CP)"],"technique_en":"Ion chromatography with conductometric detection (IC-CP)","computed":[],"computed_en":[],"activity":"Stężenie anionów:\nZakres:\nAzotany (5,0 – 200) mg/l\nAzotyny (0,050 – 2,0) mg/l\nChlorki (5,0 – 400) mg/l\nFluorki (0,15 – 3,0) mg/l\nSiarczany (5,0 – 300) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CP)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie anionów:\nZakres:\nAzotany (5,0 – 200) mg/l\nAzotyny (0,050 – 2,0) mg/l\nChlorki (5,0 – 400) mg/l\nFluorki (0,15 – 3,0) mg/l\nSiarczany (5,0 – 300) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CP) PN-EN ISO 10304-1:2009+AC:2012 Woda do spozycia przez ludzi Stezenie anionow:\nZakres:\nAzotany (5,0 – 200) mg/l\nAzotyny (0,050 – 2,0) mg/l\nChlorki (5,0 – 400) mg/l\nFluorki (0,15 – 3,0) mg/l\nSiarczany (5,0 – 300) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CP) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":24,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Anion concentrations: Ion chromatography with conductometric detection (IC-CP) Nitrates Nitrites Chlorides Fluorides Sulfates PN-EN ISO 10304-1:2009+AC:2012","methodology_zh":"阴离子浓度：","parameters_zh":[{"name":"硝酸盐","range":"(5,0 – 200) mg/l"},{"name":"亚硝酸盐","range":"(0,050 – 2,0) mg/l"},{"name":"氯化物","range":"(5,0 – 400) mg/l"},{"name":"氟化物","range":"(0,15 – 3,0) mg/l"},{"name":"硫酸盐","range":"(5,0 – 300) mg/l"}],"search_zh":"生活饮用水 阴离子浓度： 硝酸盐 亚硝酸盐 氯化物 氟化物 硫酸盐 PN-EN ISO 10304-1:2009+AC:2012","test_object_zh":"生活饮用水"},{"_id":"6a5dc9b1f1c10c8ce825bbcf","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie pierwiastków:","methodology_en":"Element concentrations:","parameters":[{"name":"Antymon","range":"(1,5 – 12) μg/l"},{"name":"Arsen","range":"(2 – 100) μg/l"},{"name":"Chrom","range":"(5 – 100) μg/l"},{"name":"Glin","range":"(20 – 300) μg/l"},{"name":"Kadm","range":"(0,5 – 10) μg/l"},{"name":"Mangan","range":"(10 – 600) μg/l"},{"name":"Nikiel","range":"(6 – 250) μg/l"},{"name":"Ołów","range":"(3 – 50) μg/l"},{"name":"Selen","range":"(3 – 15) μg/l"}],"parameters_en":[{"name":"Antimony","range":"(1,5 – 12) μg/l"},{"name":"Arsenic","range":"(2 – 100) μg/l"},{"name":"Chromium","range":"(5 – 100) μg/l"},{"name":"Aluminium","range":"(20 – 300) μg/l"},{"name":"Cadmium","range":"(0,5 – 10) μg/l"},{"name":"Manganese","range":"(10 – 600) μg/l"},{"name":"Nickel","range":"(6 – 250) μg/l"},{"name":"Lead","range":"(3 – 50) μg/l"},{"name":"Selenium","range":"(3 – 15) μg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)"],"technique_en":"Electrothermal atomization atomic absorption spectrometry (ETAAS)","computed":[],"computed_en":[],"activity":"Stężenie pierwiastków:\nZakres:\nAntymon (1,5 – 12) μg/l\nArsen (2 – 100) μg/l\nChrom (5 – 100) μg/l\nGlin (20 – 300) μg/l\nKadm (0,5 – 10) μg/l\nMangan (10 – 600) μg/l\nNikiel (6 – 250) μg/l\nOłów (3 – 50) μg/l\nSelen (3 – 15) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","reference":"PN-EN ISO 15586:2005","norm_bases":["PN-EN ISO 15586:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie pierwiastków:\nZakres:\nAntymon (1,5 – 12) μg/l\nArsen (2 – 100) μg/l\nChrom (5 – 100) μg/l\nGlin (20 – 300) μg/l\nKadm (0,5 – 10) μg/l\nMangan (10 – 600) μg/l\nNikiel (6 – 250) μg/l\nOłów (3 – 50) μg/l\nSelen (3 – 15) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS) PN-EN ISO 15586:2005 Woda do spozycia przez ludzi Stezenie pierwiastkow:\nZakres:\nAntymon (1,5 – 12) μg/l\nArsen (2 – 100) μg/l\nChrom (5 – 100) μg/l\nGlin (20 – 300) μg/l\nKadm (0,5 – 10) μg/l\nMangan (10 – 600) μg/l\nNikiel (6 – 250) μg/l\nOlow (3 – 50) μg/l\nSelen (3 – 15) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacja elektrotermiczna (ETAAS) PN-EN ISO 15586:2005","categories":["water"],"row_index":25,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Element concentrations: Electrothermal atomization atomic absorption spectrometry (ETAAS) Antimony Arsenic Chromium Aluminium Cadmium Manganese Nickel Lead Selenium PN-EN ISO 15586:2005","methodology_zh":"元素浓度：","parameters_zh":[{"name":"锑","range":"(1,5 – 12) μg/l"},{"name":"砷","range":"(2 – 100) μg/l"},{"name":"铬","range":"(5 – 100) μg/l"},{"name":"铝","range":"(20 – 300) μg/l"},{"name":"镉","range":"(0,5 – 10) μg/l"},{"name":"锰","range":"(10 – 600) μg/l"},{"name":"镍","range":"(6 – 250) μg/l"},{"name":"铅","range":"(3 – 50) μg/l"},{"name":"硒","range":"(3 – 15) μg/l"}],"search_zh":"生活饮用水 元素浓度： 电热原子化原子吸收光谱法（ETAAS） 锑 砷 铬 铝 镉 锰 镍 铅 硒 PN-EN ISO 15586:2005","technique_zh":"电热原子化原子吸收光谱法（ETAAS）","test_object_zh":"生活饮用水"},{"_id":"6a5dc9b1f1c10c8ce825bbd0","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie związków lotnych:","methodology_en":"Concentration of volatile compounds:","parameters":[{"name":"Benzen","range":"(0,3 – 5) μg/l"},{"name":"Bromodichlorometan","range":"(5 – 100) μg/l"},{"name":"Tetrachloroeten","range":"(1,5 – 20) μg/l"},{"name":"Trichloroeten","range":"(1,5 – 20) μg/l"},{"name":"Σ trichloroetenu i tetrachloroetenu z obliczeń"},{"name":"Trichlorometan (chloroform)","range":"(5 – 100) μg/l"},{"name":"Suma THM (Trichlorometan, Bromodichlorometan, Dibromochlorometan Tribromometan) z obliczeń"},{"name":"1,2-dichloroetan","range":"(0,4 – 5) μg/l"}],"parameters_en":[{"name":"Benzene","range":"(0,3 – 5) μg/l"},{"name":"Bromodichloromethane","range":"(5 – 100) μg/l"},{"name":"Tetrachloroethene","range":"(1,5 – 20) μg/l"},{"name":"Trichloroethene","range":"(1,5 – 20) μg/l"},{"name":"Σ trichloroethene and tetrachloroethene calculated"},{"name":"Trichloromethane (chloroform)","range":"(5 – 100) μg/l"},{"name":"Sum of THM (Trichloromethane, Bromodichloromethane, Dibromochloromethane Tribromomethane) calculated"},{"name":"1,2-dichloroethane","range":"(0,4 – 5) μg/l"}],"technique":"Metoda chromatografii gazowej z zastosowaniem techniki wyłapywania i wypłukiwania (Purge&Trap) z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z zastosowaniem techniki wyłapywania i wypłukiwania (Purge&Trap) z detekcją spektrometrią mas (GC-MS)"],"technique_en":"Gas chromatography using the purge and trap technique (Purge&Trap) with mass spectrometry detection (GC-MS)","computed":[],"computed_en":[],"activity":"Stężenie związków lotnych:\nZakres:\nBenzen (0,3 – 5) μg/l\nBromodichlorometan (5 – 100) μg/l\nTetrachloroeten (1,5 – 20) μg/l\nTrichloroeten (1,5 – 20) μg/l\nΣ trichloroetenu i tetrachloroetenu z obliczeń\nTrichlorometan (chloroform) (5 – 100) μg/l\nSuma THM (Trichlorometan, Bromodichlorometan, Dibromochlorometan Tribromometan) z obliczeń\n1,2-dichloroetan (0,4 – 5) μg/l\nMetoda chromatografii gazowej z zastosowaniem techniki wyłapywania i wypłukiwania (Purge&Trap) z detekcją spektrometrią mas (GC-MS)","reference":"PN-EN ISO 15680:2008","norm_bases":["PN-EN ISO 15680:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie związków lotnych:\nZakres:\nBenzen (0,3 – 5) μg/l\nBromodichlorometan (5 – 100) μg/l\nTetrachloroeten (1,5 – 20) μg/l\nTrichloroeten (1,5 – 20) μg/l\nΣ trichloroetenu i tetrachloroetenu z obliczeń\nTrichlorometan (chloroform) (5 – 100) μg/l\nSuma THM (Trichlorometan, Bromodichlorometan, Dibromochlorometan Tribromometan) z obliczeń\n1,2-dichloroetan (0,4 – 5) μg/l\nMetoda chromatografii gazowej z zastosowaniem techniki wyłapywania i wypłukiwania (Purge&Trap) z detekcją spektrometrią mas (GC-MS) PN-EN ISO 15680:2008 Woda do spozycia przez ludzi Stezenie zwiazkow lotnych:\nZakres:\nBenzen (0,3 – 5) μg/l\nBromodichlorometan (5 – 100) μg/l\nTetrachloroeten (1,5 – 20) μg/l\nTrichloroeten (1,5 – 20) μg/l\nΣ trichloroetenu i tetrachloroetenu z obliczen\nTrichlorometan (chloroform) (5 – 100) μg/l\nSuma THM (Trichlorometan, Bromodichlorometan, Dibromochlorometan Tribromometan) z obliczen\n1,2-dichloroetan (0,4 – 5) μg/l\nMetoda chromatografii gazowej z zastosowaniem techniki wylapywania i wyplukiwania (Purge&Trap) z detekcja spektrometria mas (GC-MS) PN-EN ISO 15680:2008","categories":["water"],"row_index":26,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Concentration of volatile compounds: Gas chromatography using the purge and trap technique (Purge&Trap) with mass spectrometry detection (GC-MS) Benzene Bromodichloromethane Tetrachloroethene Trichloroethene Σ trichloroethene and tetrachloroethene calculated Trichloromethane (chloroform) Sum of THM (Trichloromethane, Bromodichloromethane, Dibromochloromethane Tribromomethane) calculated 1,2-dichloroethane PN-EN ISO 15680:2008","search_zh":"生活饮用水 吹扫捕集气相色谱-质谱检测法（GC-MS） 苯 一溴二氯甲烷 四氯乙烯 三氯乙烯 1,2-二氯乙烷 PN-EN ISO 15680:2008","test_object_zh":"生活饮用水","parameters_zh":[{"name":"苯","range":"(0,3 – 5) μg/l"},{"name":"一溴二氯甲烷","range":"(5 – 100) μg/l"},{"name":"四氯乙烯","range":"(1,5 – 20) μg/l"},{"name":"三氯乙烯","range":"(1,5 – 20) μg/l"},{"name":"Σ trichloroetenu i tetrachloroetenu z obliczeń"},{"name":"Trichlorometan (chloroform)","range":"(5 – 100) μg/l"},{"name":"Suma THM (Trichlorometan, Bromodichlorometan, Dibromochlorometan Tribromometan) z obliczeń"},{"name":"1,2-二氯乙烷","range":"(0,4 – 5) μg/l"}],"technique_zh":"吹扫捕集气相色谱-质谱检测法（GC-MS）"},{"_id":"6a5dc9b1f1c10c8ce825bbd1","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Liczba progowa smaku","methodology_en":"Taste threshold number","parameters":[{"name":"Zakres","range":"(1 – 8) TFN"}],"parameters_en":[{"name":"Range","range":"(1 – 8) TFN"}],"technique":"Metoda uproszczona; Metoda pełna, parzysta, wybór niewymuszony","techniques":["Metoda uproszczona","Metoda pełna, parzysta, wybór niewymuszony"],"technique_en":"Simplified method; Full paired method, non-forced choice","computed":[],"computed_en":[],"activity":"Liczba progowa smaku\nZakres (1 – 8) TFN\nMetoda uproszczona; Metoda pełna, parzysta, wybór niewymuszony","reference":"PN-EN 1622:2006","norm_bases":["PN-EN 1622:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Liczba progowa smaku\nZakres (1 – 8) TFN\nMetoda uproszczona; Metoda pełna, parzysta, wybór niewymuszony PN-EN 1622:2006 Woda do spozycia przez ludzi Liczba progowa smaku\nZakres (1 – 8) TFN\nMetoda uproszczona; Metoda pelna, parzysta, wybor niewymuszony PN-EN 1622:2006","categories":["water"],"row_index":27,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Taste threshold number Simplified method; Full paired method, non-forced choice Range PN-EN 1622:2006","parameters_zh":[{"name":"范围","range":"(1 – 8) TFN"}],"search_zh":"生活饮用水 范围 PN-EN 1622:2006","test_object_zh":"生活饮用水"},{"_id":"6a5dc9b1f1c10c8ce825bbd2","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Liczba progowa zapachu","methodology_en":"Odour threshold number","parameters":[{"name":"Zakres","range":"(1 – 8) TON"}],"parameters_en":[{"name":"Range","range":"(1 – 8) TON"}],"technique":"Metoda uproszczona; Metoda pełna, parzysta, wybór niewymuszony","techniques":["Metoda uproszczona","Metoda pełna, parzysta, wybór niewymuszony"],"technique_en":"Simplified method; Full paired method, non-forced choice","computed":[],"computed_en":[],"activity":"Liczba progowa zapachu\nZakres (1 – 8) TON\nMetoda uproszczona; Metoda pełna, parzysta, wybór niewymuszony","reference":"PN-EN 1622:2006","norm_bases":["PN-EN 1622:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Liczba progowa zapachu\nZakres (1 – 8) TON\nMetoda uproszczona; Metoda pełna, parzysta, wybór niewymuszony PN-EN 1622:2006 Woda do spozycia przez ludzi Liczba progowa zapachu\nZakres (1 – 8) TON\nMetoda uproszczona; Metoda pelna, parzysta, wybor niewymuszony PN-EN 1622:2006","categories":["water"],"row_index":28,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Odour threshold number Simplified method; Full paired method, non-forced choice Range PN-EN 1622:2006","parameters_zh":[{"name":"范围","range":"(1 – 8) TON"}],"search_zh":"生活饮用水 范围 PN-EN 1622:2006","test_object_zh":"生活饮用水"},{"_id":"6a5dc9b1f1c10c8ce825bbd3","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie pierwiastków","methodology_en":"Element concentration","parameters":[{"name":"Chrom","range":"(10,0 - 60) μg/l"},{"name":"Kadm","range":"(1,00 – 10,0) μg/l"},{"name":"Nikiel","range":"(1,00 – 40,0) μg/l"},{"name":"Ołów","range":"(1,00 – 20,0) μg/l"}],"parameters_en":[{"name":"Chromium","range":"(10,0 - 60) μg/l"},{"name":"Cadmium","range":"(1,00 – 10,0) μg/l"},{"name":"Nickel","range":"(1,00 – 40,0) μg/l"},{"name":"Lead","range":"(1,00 – 20,0) μg/l"}],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","computed":[],"computed_en":[],"activity":"Stężenie pierwiastków\nZakres:\nChrom (10,0 - 60) μg/l\nKadm (1,00 – 10,0) μg/l\nNikiel (1,00 – 40,0) μg/l\nOłów (1,00 – 20,0) μg/l\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"PN-EN ISO 17294-2:2024-04","norm_bases":["PN-EN ISO 17294-2:2024-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie pierwiastków\nZakres:\nChrom (10,0 - 60) μg/l\nKadm (1,00 – 10,0) μg/l\nNikiel (1,00 – 40,0) μg/l\nOłów (1,00 – 20,0) μg/l\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) PN-EN ISO 17294-2:2024-04 Woda do spozycia przez ludzi Stezenie pierwiastkow\nZakres:\nChrom (10,0 - 60) μg/l\nKadm (1,00 – 10,0) μg/l\nNikiel (1,00 – 40,0) μg/l\nOlow (1,00 – 20,0) μg/l\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) PN-EN ISO 17294-2:2024-04","categories":["water"],"row_index":29,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Element concentration Inductively coupled plasma mass spectrometry (ICP-MS) Chromium Cadmium Nickel Lead PN-EN ISO 17294-2:2024-04","methodology_zh":"元素浓度","parameters_zh":[{"name":"铬","range":"(10,0 - 60) μg/l"},{"name":"镉","range":"(1,00 – 10,0) μg/l"},{"name":"镍","range":"(1,00 – 40,0) μg/l"},{"name":"铅","range":"(1,00 – 20,0) μg/l"}],"search_zh":"生活饮用水 元素浓度 电感耦合等离子体质谱法（ICP-MS） 铬 镉 镍 铅 PN-EN ISO 17294-2:2024-04","technique_zh":"电感耦合等离子体质谱法（ICP-MS）","test_object_zh":"生活饮用水"},{"_id":"6a5dc9b1f1c10c8ce825bbd4","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Ogólna liczba mikroorganizmów w temperaturze 36 oC","methodology_en":"Total count of microorganisms at 36 oC","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"technique_en":"Plate method (pour plate)","computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w temperaturze 36 oC\nMetoda płytkowa (posiew wgłębny)","reference":"PN- EN ISO 6222:2004","norm_bases":["PN- EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w temperaturze 36 oC\nMetoda płytkowa (posiew wgłębny) PN- EN ISO 6222:2004 Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w temperaturze 36 oC\nMetoda plytkowa (posiew wglebny) PN- EN ISO 6222:2004","categories":["water"],"row_index":30,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Total count of microorganisms at 36 oC Plate method (pour plate) PN- EN ISO 6222:2004","search_zh":"生活饮用水 平板法（倾注培养） PN- EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"生活饮用水"},{"_id":"6a5dc9b1f1c10c8ce825bbd5","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Ogólna liczba mikroorganizmów w temperaturze 22 oC","methodology_en":"Total count of microorganisms at 22 oC","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"technique_en":"Plate method (pour plate)","computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w temperaturze 22 oC\nMetoda płytkowa (posiew wgłębny)","reference":"PN- EN ISO 6222:2004","norm_bases":["PN- EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w temperaturze 22 oC\nMetoda płytkowa (posiew wgłębny) PN- EN ISO 6222:2004 Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w temperaturze 22 oC\nMetoda plytkowa (posiew wglebny) PN- EN ISO 6222:2004","categories":["water"],"row_index":31,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Total count of microorganisms at 22 oC Plate method (pour plate) PN- EN ISO 6222:2004","search_zh":"生活饮用水 平板法（倾注培养） PN- EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"生活饮用水"},{"_id":"6a5dc9b1f1c10c8ce825bbd6","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Liczba enterokoków kałowych","methodology_en":"Intestinal enterococci count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba enterokoków kałowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Liczba enterokoków kałowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda do spozycia przez ludzi Liczba enterokokow kalowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":32,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004","methodology_zh":"粪肠球菌计数","search_zh":"生活饮用水 粪肠球菌计数 膜过滤法 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9b1f1c10c8ce825bbd7","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Liczba Clostridium perfringens (łącznie z przetrwalnikami)","methodology_en":"Clostridium perfringens count (including spores)","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Clostridium perfringens (łącznie z przetrwalnikami)\nMetoda filtracji membranowej","reference":"PN-EN ISO 14189:2016-10","norm_bases":["PN-EN ISO 14189:2016-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Liczba Clostridium perfringens (łącznie z przetrwalnikami)\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10 Woda do spozycia przez ludzi Liczba Clostridium perfringens (lacznie z przetrwalnikami)\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10","categories":["water"],"row_index":33,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Clostridium perfringens count (including spores) Membrane filtration method PN-EN ISO 14189:2016-10","search_zh":"生活饮用水 产气荚膜梭菌数（含芽孢） 膜过滤法 PN-EN ISO 14189:2016-10","technique_zh":"膜过滤法","test_object_zh":"生活饮用水","methodology_zh":"产气荚膜梭菌数（含芽孢）"},{"_id":"6a5dc9b1f1c10c8ce825bbd8","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Najbardziej prawdopodobna liczba bakterii z grupy coli","methodology_en":"Most probable number of coliform bacteria","parameters":[],"parameters_en":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"technique_en":"MPN method","computed":[],"computed_en":[],"activity":"Najbardziej prawdopodobna liczba bakterii z grupy coli\nMetoda NPL","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Najbardziej prawdopodobna liczba bakterii z grupy coli\nMetoda NPL PN-EN ISO 9308-2:2014-06 Woda do spozycia przez ludzi Najbardziej prawdopodobna liczba bakterii z grupy coli\nMetoda NPL PN-EN ISO 9308-2:2014-06","categories":["water","microbiology"],"row_index":34,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Most probable number of coliform bacteria MPN method PN-EN ISO 9308-2:2014-06","search_zh":"生活饮用水 大肠菌群最可能数 最可能数法（MPN） PN-EN ISO 9308-2:2014-06","technique_zh":"最可能数法（MPN）","test_object_zh":"生活饮用水","methodology_zh":"大肠菌群最可能数"},{"_id":"6a5dc9b1f1c10c8ce825bbd9","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Najbardziej prawdopodobna liczba, Escherichia coli","methodology_en":"Most probable number, Escherichia coli","parameters":[],"parameters_en":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"technique_en":"MPN method","computed":[],"computed_en":[],"activity":"Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda NPL","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda NPL PN-EN ISO 9308-2:2014-06 Woda do spozycia przez ludzi Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda NPL PN-EN ISO 9308-2:2014-06","categories":["water","microbiology"],"row_index":35,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Most probable number, Escherichia coli MPN method PN-EN ISO 9308-2:2014-06","methodology_zh":"大肠埃希氏菌（Escherichia coli）最可能数（MPN）","search_zh":"生活饮用水 大肠埃希氏菌（Escherichia coli）最可能数（MPN） 最可能数法（MPN） PN-EN ISO 9308-2:2014-06","technique_zh":"最可能数法（MPN）","test_object_zh":"生活饮用水"},{"_id":"6a5dc9b1f1c10c8ce825bbda","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Liczba bakterii grupy coli","methodology_en":"Coliform bacteria count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda do spozycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":36,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04","methodology_zh":"大肠菌群计数","search_zh":"生活饮用水 大肠菌群计数 膜过滤法 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9b1f1c10c8ce825bbdb","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Liczba Escherichia coli","methodology_en":"Escherichia coli count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014–12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014–12 +A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014–12 +A1:2017-04 Woda do spozycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014–12 +A1:2017-04","categories":["water","microbiology"],"row_index":37,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014–12 +A1:2017-04","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"生活饮用水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PN-EN ISO 9308-1:2014–12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9b1f1c10c8ce825bbdc","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Pobieranie próbek do badań chemicznych i do badań właściwości fizycznych","methodology_en":"Sampling for chemical testing and for testing of physical properties","parameters":[{"name":"Temperatura ścieków / pobranej próbki ścieków"},{"name":"Zakres","range":"(2,0 – 50,0) oC"}],"parameters_en":[{"name":"Temperature of wastewater / collected wastewater sample"},{"name":"Range","range":"(2,0 – 50,0) oC"}],"technique":"Metoda manualna; Metoda automatyczna","techniques":["Metoda manualna","Metoda automatyczna"],"technique_en":"Manual method; Automatic method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i do badań właściwości fizycznych\nZakres:\nTemperatura ścieków / pobranej próbki ścieków\nZakres (2,0 – 50,0) oC\nMetoda manualna; Metoda automatyczna","reference":"PN-ISO 5667-10:2021-11 | PN-C-04584:1977","norm_bases":["PN-ISO 5667-10:2021-11","PN-C-04584:1977"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i do badań właściwości fizycznych\nZakres:\nTemperatura ścieków / pobranej próbki ścieków\nZakres (2,0 – 50,0) oC\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 | PN-C-04584:1977 Scieki Pobieranie probek do badan chemicznych i do badan wlasciwosci fizycznych\nZakres:\nTemperatura sciekow / pobranej probki sciekow\nZakres (2,0 – 50,0) oC\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 | PN-C-04584:1977","categories":["water"],"row_index":38,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Sampling for chemical testing and for testing of physical properties Manual method; Automatic method Temperature of wastewater / collected wastewater sample Range PN-ISO 5667-10:2021-11 | PN-C-04584:1977","parameters_zh":[{"name":"废水/所采废水样品的温度"},{"name":"范围","range":"(2,0 – 50,0) oC"}],"search_zh":"污水 手动法；自动法 废水/所采废水样品的温度 范围 PN-ISO 5667-10:2021-11 | PN-C-04584:1977","technique_zh":"手动法；自动法","test_object_zh":"污水"},{"_id":"6a5dc9b1f1c10c8ce825bbdd","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Scieki pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":39,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"污水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"污水"},{"_id":"6a5dc9b1f1c10c8ce825bbde","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Pobieranie próbek do badań chemicznych i do badań właściwości fizycznych","methodology_en":"Sampling for chemical testing and for testing of physical properties","parameters":[{"name":"Temperatura pobranej próbki wody"},{"name":"Zakres","range":"(2,0 – 50,0) oC"}],"parameters_en":[{"name":"Temperature of the collected water sample"},{"name":"Range","range":"(2,0 – 50,0) oC"}],"technique":"Metoda manualna","techniques":["Metoda manualna"],"technique_en":"Manual method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i do badań właściwości fizycznych\nZakres:\nTemperatura pobranej próbki wody\nZakres (2,0 – 50,0) oC\nMetoda manualna","reference":"PN-EN ISO 5667-6:2016-12 z wyłączeniem 7.3, 7.5, 7.6, 8.2, 9.4. | PN-C-04584:1977","norm_bases":["PN-EN ISO 5667-6:2016-12 z wyłączeniem 7.3, 7.5, 7.6, 8.2, 9.4.","PN-C-04584:1977"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Pobieranie próbek do badań chemicznych i do badań właściwości fizycznych\nZakres:\nTemperatura pobranej próbki wody\nZakres (2,0 – 50,0) oC\nMetoda manualna PN-EN ISO 5667-6:2016-12 z wyłączeniem 7.3, 7.5, 7.6, 8.2, 9.4. | PN-C-04584:1977 Woda Pobieranie probek do badan chemicznych i do badan wlasciwosci fizycznych\nZakres:\nTemperatura pobranej probki wody\nZakres (2,0 – 50,0) oC\nMetoda manualna PN-EN ISO 5667-6:2016-12 z wylaczeniem 7.3, 7.5, 7.6, 8.2, 9.4. | PN-C-04584:1977","categories":["water"],"row_index":40,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Sampling for chemical testing and for testing of physical properties Manual method Temperature of the collected water sample Range PN-EN ISO 5667-6:2016-12 z wyłączeniem 7.3, 7.5, 7.6, 8.2, 9.4. | PN-C-04584:1977","parameters_zh":[{"name":"所采水样的温度"},{"name":"范围","range":"(2,0 – 50,0) oC"}],"search_zh":"水 手工法 所采水样的温度 范围 PN-EN ISO 5667-6:2016-12 z wyłączeniem 7.3, 7.5, 7.6, 8.2, 9.4. | PN-C-04584:1977","test_object_zh":"水","technique_zh":"手工法"},{"_id":"6a5dc9b1f1c10c8ce825bbdf","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Pobieranie próbek do badań chemicznych, biologicznych, mikrobiologicznych i do badań właściwości fizycznych","methodology_en":"Sampling for chemical, biological, microbiological testing and for testing of physical properties","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych, biologicznych, mikrobiologicznych i do badań właściwości fizycznych","reference":"PN-EN ISO 5667-13:2011","norm_bases":["PN-EN ISO 5667-13:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Pobieranie próbek do badań chemicznych, biologicznych, mikrobiologicznych i do badań właściwości fizycznych PN-EN ISO 5667-13:2011 Osady sciekowe Pobieranie probek do badan chemicznych, biologicznych, mikrobiologicznych i do badan wlasciwosci fizycznych PN-EN ISO 5667-13:2011","categories":["water","microbiology"],"row_index":41,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge Sampling for chemical, biological, microbiological testing and for testing of physical properties PN-EN ISO 5667-13:2011","search_zh":"污泥 PN-EN ISO 5667-13:2011","test_object_zh":"污泥"},{"_id":"6a5dc9b1f1c10c8ce825bbe0","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, Scieki pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":42,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"水、污水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、污水"},{"_id":"6a5dc9b1f1c10c8ce825bbe1","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr","methodology_en":"Chemical oxygen demand - COD-Cr","parameters":[{"name":"Zakres","range":"(15 – 60000) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(15 – 60000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (15 – 60000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (15 – 60000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda, Scieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (15 – 60000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":43,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Chemical oxygen demand - COD-Cr Spectrophotometric method Range PN-ISO 15705:2005","parameters_zh":[{"name":"范围","range":"(15 – 60000) mg/l O2"}],"search_zh":"水、污水 化学需氧量（COD-Cr） 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水、污水","methodology_zh":"化学需氧量（COD-Cr）"},{"_id":"6a5dc9b1f1c10c8ce825bbe2","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5","methodology_en":"Biochemical oxygen demand - BOD5","parameters":[{"name":"Zakres","range":"(1,0 – 6000) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(1,0 – 6000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (1,0 – 6000) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (1,0 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Woda, Scieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (1,0 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":44,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Biochemical oxygen demand - BOD5 Electrochemical method Range PN-EN ISO 5815-1:2019-12","parameters_zh":[{"name":"范围","range":"(1,0 – 6000) mg/l O2"}],"search_zh":"水、污水 五日生化需氧量（BOD5） 电化学法 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"水、污水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a5dc9b1f1c10c8ce825bbe3","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5","methodology_en":"Biochemical oxygen demand - BOD5","parameters":[{"name":"Zakres","range":"(1,0 – 6000) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(1,0 – 6000) mg/l O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"technique_en":"Optical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (1,0 – 6000) mg/l O2\nMetoda optyczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (1,0 – 6000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12 Woda, Scieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (1,0 – 6000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":45,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Biochemical oxygen demand - BOD5 Optical method Range PN-EN ISO 5815-1:2019-12","parameters_zh":[{"name":"范围","range":"(1,0 – 6000) mg/l O2"}],"search_zh":"水、污水 五日生化需氧量（BOD5） 光学法 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"光学法","test_object_zh":"水、污水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a5dc9b1f1c10c8ce825bbe4","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5","methodology_en":"Biochemical oxygen demand - BOD5","parameters":[{"name":"Zakres","range":"(0,5 – 6,0) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(0,5 – 6,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (0,5 – 6,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (0,5 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Woda, Scieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (0,5 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":46,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Biochemical oxygen demand - BOD5 Electrochemical method Range PN-EN 1899-2:2002","parameters_zh":[{"name":"范围","range":"(0,5 – 6,0) mg/l O2"}],"search_zh":"水、污水 五日生化需氧量（BOD5） 电化学法 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"水、污水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a5dc9b1f1c10c8ce825bbe5","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie tlenu rozpuszczonego","methodology_en":"Dissolved oxygen concentration","parameters":[{"name":"Zakres","range":"(0,5 – 15,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,5 – 15,0) mg/l"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Stężenie tlenu rozpuszczonego\nZakres (0,5 – 15,0) mg/l\nMetoda elektrochemiczna","reference":"PN-EN ISO 5814:2013","norm_bases":["PN-EN ISO 5814:2013"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie tlenu rozpuszczonego\nZakres (0,5 – 15,0) mg/l\nMetoda elektrochemiczna PN-EN ISO 5814:2013 Woda, Scieki Stezenie tlenu rozpuszczonego\nZakres (0,5 – 15,0) mg/l\nMetoda elektrochemiczna PN-EN ISO 5814:2013","categories":["water"],"row_index":47,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Dissolved oxygen concentration Electrochemical method Range PN-EN ISO 5814:2013","parameters_zh":[{"name":"范围","range":"(0,5 – 15,0) mg/l"}],"search_zh":"水、污水 溶解氧浓度 电化学法 范围 PN-EN ISO 5814:2013","technique_zh":"电化学法","test_object_zh":"水、污水","methodology_zh":"溶解氧浓度"},{"_id":"6a5dc9b1f1c10c8ce825bbe6","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Zawiesiny ogólne","methodology_en":"Total suspended solids (TSS)","parameters":[{"name":"Zakres","range":"(2,0 – 20000) mg/l"}],"parameters_en":[{"name":"Range","range":"(2,0 – 20000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 20000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Zawiesiny ogólne\nZakres (2,0 – 20000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, Scieki Zawiesiny ogolne\nZakres (2,0 – 20000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":48,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 20000) mg/l"}],"search_zh":"水、污水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"水、污水"},{"_id":"6a5dc9b1f1c10c8ce825bbe7","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie fosforu ogólnego","methodology_en":"Total phosphorus concentration","parameters":[{"name":"Zakres","range":"(0,200 – 300) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,200 – 300) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,200 – 300) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 punkt 8 + A p1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 punkt 8 + A p1:2010+Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie fosforu ogólnego\nZakres (0,200 – 300) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 punkt 8 + A p1:2010+Ap2:2010 Woda, Scieki Stezenie fosforu ogolnego\nZakres (0,200 – 300) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 punkt 8 + A p1:2010+Ap2:2010","categories":["water"],"row_index":49,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Total phosphorus concentration Spectrophotometric method Range PN-EN ISO 6878:2006 punkt 8 + A p1:2010+Ap2:2010","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,200 – 300) mg/l"}],"search_zh":"水、污水 总磷浓度 分光光度法 范围 PN-EN ISO 6878:2006 punkt 8 + A p1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a5dc9b1f1c10c8ce825bbe8","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie ortofosforanów","methodology_en":"Orthophosphate concentration","parameters":[{"name":"Zakres","range":"(0,100 – 25,0) mg/l PO4"},{"name":"Zakres","range":"(0,033 – 8,15) mg/l P-PO4"}],"parameters_en":[{"name":"Range","range":"(0,100 – 25,0) mg/l PO4"},{"name":"Range","range":"(0,033 – 8,15) mg/l P-PO4"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie ortofosforanów\nZakres:\nZakres (0,100 – 25,0) mg/l PO4\nZakres (0,033 – 8,15) mg/l P-PO4\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 punkt 4 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 punkt 4 +Ap1:2010+Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie ortofosforanów\nZakres:\nZakres (0,100 – 25,0) mg/l PO4\nZakres (0,033 – 8,15) mg/l P-PO4\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 punkt 4 +Ap1:2010+Ap2:2010 Woda, Scieki Stezenie ortofosforanow\nZakres:\nZakres (0,100 – 25,0) mg/l PO4\nZakres (0,033 – 8,15) mg/l P-PO4\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 punkt 4 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":50,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Orthophosphate concentration Spectrophotometric method Range Range PN-EN ISO 6878:2006 punkt 4 +Ap1:2010+Ap2:2010","parameters_zh":[{"name":"范围","range":"(0,100 – 25,0) mg/l PO4"},{"name":"范围","range":"(0,033 – 8,15) mg/l P-PO4"}],"search_zh":"水、污水 正磷酸盐浓度 分光光度法 范围 范围 PN-EN ISO 6878:2006 punkt 4 +Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水、污水","methodology_zh":"正磷酸盐浓度"},{"_id":"6a5dc9b1f1c10c8ce825bbe9","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie azotu amonowego","methodology_en":"Ammonium nitrogen concentration","parameters":[{"name":"Zakres","range":"(1,00 – 2000) mg/l"}],"parameters_en":[{"name":"Range","range":"(1,00 – 2000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego\nZakres (1,00 – 2000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie azotu amonowego\nZakres (1,00 – 2000) mg/l\nMetoda miareczkowa PN-ISO 5664:2002 Woda, Scieki Stezenie azotu amonowego\nZakres (1,00 – 2000) mg/l\nMetoda miareczkowa PN-ISO 5664:2002","categories":["water"],"row_index":51,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Ammonium nitrogen concentration Titrimetric method Range PN-ISO 5664:2002","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(1,00 – 2000) mg/l"}],"search_zh":"水、污水 氨氮浓度 滴定法 范围 PN-ISO 5664:2002","technique_zh":"滴定法","test_object_zh":"水、污水"},{"_id":"6a5dc9b1f1c10c8ce825bbea","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Ścieki, Woda","test_object_en":"Wastewater, Water","methodology":"Stężenie azotu Kjeldahla","methodology_en":"Kjeldahl nitrogen concentration","parameters":[{"name":"Zakres","range":"(1,00 – 1000) mg/l"}],"parameters_en":[{"name":"Range","range":"(1,00 – 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie azotu Kjeldahla\nZakres (1,00 – 1000) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, Woda Stężenie azotu Kjeldahla\nZakres (1,00 – 1000) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Scieki, Woda Stezenie azotu Kjeldahla\nZakres (1,00 – 1000) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":52,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, Water Kjeldahl nitrogen concentration Titrimetric method Range PN-EN 25663:2001","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(1,00 – 1000) mg/l"}],"search_zh":"废水、水 凯氏氮浓度 滴定法 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"废水、水"},{"_id":"6a5dc9b1f1c10c8ce825bbeb","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Ścieki, Woda","test_object_en":"Wastewater, Water","methodology":"Stężenie azotu azotanowego","methodology_en":"Nitrate nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,100 – 50,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,100 – 50,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu azotanowego\nZakres (0,100 – 50,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, Woda Stężenie azotu azotanowego\nZakres (0,100 – 50,0) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08 Scieki, Woda Stezenie azotu azotanowego\nZakres (0,100 – 50,0) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":53,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, Water Nitrate nitrogen concentration Spectrophotometric method Range PN-82/C-04576/08","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,100 – 50,0) mg/l"}],"search_zh":"废水、水 硝态氮浓度 分光光度法 范围 PN-82/C-04576/08","technique_zh":"分光光度法","test_object_zh":"废水、水"},{"_id":"6a5dc9b1f1c10c8ce825bbec","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Ścieki, Woda","test_object_en":"Wastewater, Water","methodology":"Stężenie azotu azotynowego","methodology_en":"Nitrite nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,020 – 10,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,020 – 10,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu azotynowego\nZakres (0,020 – 10,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, Woda Stężenie azotu azotynowego\nZakres (0,020 – 10,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Scieki, Woda Stezenie azotu azotynowego\nZakres (0,020 – 10,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":54,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, Water Nitrite nitrogen concentration Spectrophotometric method Range PN-EN 26777:1999","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,020 – 10,0) mg/l"}],"search_zh":"废水、水 亚硝态氮浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"废水、水"},{"_id":"6a5dc9b1f1c10c8ce825bbed","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Ścieki, Woda","test_object_en":"Wastewater, Water","methodology":"Stężenie azotu ogólnego (z obliczeń)","methodology_en":"Total nitrogen concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PN-C-04576-14:1973","norm_bases":["PN-C-04576-14:1973"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, Woda Stężenie azotu ogólnego (z obliczeń) PN-C-04576-14:1973 Scieki, Woda Stezenie azotu ogolnego (z obliczen) PN-C-04576-14:1973","categories":["water"],"row_index":55,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, Water Total nitrogen concentration (calculated) PN-C-04576-14:1973","methodology_zh":"总氮浓度（计算值）","search_zh":"废水、水 总氮浓度（计算值） PN-C-04576-14:1973","test_object_zh":"废水、水"},{"_id":"6a5dc9b1f1c10c8ce825bbee","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Ścieki, Woda","test_object_en":"Wastewater, Water","methodology":"Substancje ekstrahujące się eterem naftowym","methodology_en":"Substances extractable with petroleum ether","parameters":[{"name":"Zakres","range":"(8,0 – 10000) mg/l"}],"parameters_en":[{"name":"Range","range":"(8,0 – 10000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Substancje ekstrahujące się eterem naftowym\nZakres (8,0 – 10000) mg/l\nMetoda wagowa","reference":"PB-26 wyd. 2 z dnia 01.09.2011","norm_bases":["PB-26 wyd. 2 z dnia 01.09.2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, Woda Substancje ekstrahujące się eterem naftowym\nZakres (8,0 – 10000) mg/l\nMetoda wagowa PB-26 wyd. 2 z dnia 01.09.2011 Scieki, Woda Substancje ekstrahujace sie eterem naftowym\nZakres (8,0 – 10000) mg/l\nMetoda wagowa PB-26 wyd. 2 z dnia 01.09.2011","categories":["water"],"row_index":56,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, Water Substances extractable with petroleum ether Gravimetric method Range PB-26 wyd. 2 z dnia 01.09.2011","parameters_zh":[{"name":"范围","range":"(8,0 – 10000) mg/l"}],"search_zh":"废水、水 石油醚可萃取物 重量法 范围 PB-26 wyd. 2 z dnia 01.09.2011","technique_zh":"重量法","test_object_zh":"废水、水","methodology_zh":"石油醚可萃取物"},{"_id":"6a5dc9b1f1c10c8ce825bbef","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Ścieki, Woda","test_object_en":"Wastewater, Water","methodology":"Stężenie chlorków","methodology_en":"Chloride concentration","parameters":[{"name":"Zakres","range":"(5,0 – 50000) mg/l"}],"parameters_en":[{"name":"Range","range":"(5,0 – 50000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie chlorków\nZakres (5,0 – 50000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, Woda Stężenie chlorków\nZakres (5,0 – 50000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Scieki, Woda Stezenie chlorkow\nZakres (5,0 – 50000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":57,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, Water Chloride concentration Titrimetric method Range PN-ISO 9297:1994","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,0 – 50000) mg/l"}],"search_zh":"废水、水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"废水、水"},{"_id":"6a5dc9b1f1c10c8ce825bbf0","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Ścieki, Woda","test_object_en":"Wastewater, Water","methodology":"Stężenie siarczanów","methodology_en":"Sulfate concentration","parameters":[{"name":"Zakres","range":"(10,0 – 2000) mg/l"}],"parameters_en":[{"name":"Range","range":"(10,0 – 2000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie siarczanów\nZakres (10,0 – 2000) mg/l\nMetoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, Woda Stężenie siarczanów\nZakres (10,0 – 2000) mg/l\nMetoda wagowa PN-ISO 9280:2002 Scieki, Woda Stezenie siarczanow\nZakres (10,0 – 2000) mg/l\nMetoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":58,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, Water Sulfate concentration Gravimetric method Range PN-ISO 9280:2002","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(10,0 – 2000) mg/l"}],"search_zh":"废水、水 硫酸盐浓度 重量法 范围 PN-ISO 9280:2002","technique_zh":"重量法","test_object_zh":"废水、水"},{"_id":"6a5dc9b1f1c10c8ce825bbf1","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Ścieki, Woda","test_object_en":"Wastewater, Water","methodology":"Przewodność elektryczna właściwa","methodology_en":"Electrical conductivity","parameters":[{"name":"Zakres","range":"(0,200 – 18,00) mS/cm"}],"parameters_en":[{"name":"Range","range":"(0,200 – 18,00) mS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"technique_en":"Conductometric method","computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa\nZakres (0,200 – 18,00) mS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, Woda Przewodność elektryczna właściwa\nZakres (0,200 – 18,00) mS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Scieki, Woda Przewodnosc elektryczna wlasciwa\nZakres (0,200 – 18,00) mS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":59,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, Water Electrical conductivity Conductometric method Range PN-EN 27888:1999","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(0,200 – 18,00) mS/cm"}],"search_zh":"废水、水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"废水、水"},{"_id":"6a5dc9b1f1c10c8ce825bbf2","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Ścieki, Woda","test_object_en":"Wastewater, Water","methodology":"Indeks fenolowy","methodology_en":"Phenol index","parameters":[{"name":"Zakres","range":"(0,002 – 10,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,002 – 10,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Indeks fenolowy\nZakres (0,002 – 10,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6439:1994","norm_bases":["PN-ISO 6439:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, Woda Indeks fenolowy\nZakres (0,002 – 10,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6439:1994 Scieki, Woda Indeks fenolowy\nZakres (0,002 – 10,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6439:1994","categories":["water"],"row_index":60,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, Water Phenol index Spectrophotometric method Range PN-ISO 6439:1994","parameters_zh":[{"name":"范围","range":"(0,002 – 10,0) mg/l"}],"search_zh":"废水、水 酚指数 分光光度法 范围 PN-ISO 6439:1994","technique_zh":"分光光度法","methodology_zh":"酚指数","test_object_zh":"废水、水"},{"_id":"6a5dc9b1f1c10c8ce825bbf3","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Ścieki, Woda","test_object_en":"Wastewater, Water","methodology":"Stężenie pierwiastków:","methodology_en":"Element concentrations:","parameters":[{"name":"cynk","range":"(0,05 – 50,0) mg/l"},{"name":"miedź","range":"(0,05 – 10,0) mg/l"},{"name":"nikiel","range":"(0,20 – 3,20) mg/l"},{"name":"ołów","range":"(0,20 – 3,20) mg/l"},{"name":"kadm","range":"(0,025 – 0,400) mg/l"}],"parameters_en":[{"name":"zinc","range":"(0,05 – 50,0) mg/l"},{"name":"copper","range":"(0,05 – 10,0) mg/l"},{"name":"nickel","range":"(0,20 – 3,20) mg/l"},{"name":"lead","range":"(0,20 – 3,20) mg/l"},{"name":"cadmium","range":"(0,025 – 0,400) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"technique_en":"Flame atomic absorption spectrometry (FAAS)","computed":[],"computed_en":[],"activity":"Stężenie pierwiastków:\nZakres:\ncynk (0,05 – 50,0) mg/l\nmiedź (0,05 – 10,0) mg/l\nnikiel (0,20 – 3,20) mg/l\nołów (0,20 – 3,20) mg/l\nkadm (0,025 – 0,400) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 8288:2002 metoda A","norm_bases":["PN-ISO 8288:2002 metoda A"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, Woda Stężenie pierwiastków:\nZakres:\ncynk (0,05 – 50,0) mg/l\nmiedź (0,05 – 10,0) mg/l\nnikiel (0,20 – 3,20) mg/l\nołów (0,20 – 3,20) mg/l\nkadm (0,025 – 0,400) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 metoda A Scieki, Woda Stezenie pierwiastkow:\nZakres:\ncynk (0,05 – 50,0) mg/l\nmiedz (0,05 – 10,0) mg/l\nnikiel (0,20 – 3,20) mg/l\nolow (0,20 – 3,20) mg/l\nkadm (0,025 – 0,400) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 metoda A","categories":["water","materials"],"row_index":61,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, Water Element concentrations: Flame atomic absorption spectrometry (FAAS) zinc copper nickel lead cadmium PN-ISO 8288:2002 metoda A","methodology_zh":"元素浓度：","parameters_zh":[{"name":"锌","range":"(0,05 – 50,0) mg/l"},{"name":"铜","range":"(0,05 – 10,0) mg/l"},{"name":"镍","range":"(0,20 – 3,20) mg/l"},{"name":"铅","range":"(0,20 – 3,20) mg/l"},{"name":"镉","range":"(0,025 – 0,400) mg/l"}],"search_zh":"废水、水 元素浓度： 火焰原子吸收光谱法（FAAS） 锌 铜 镍 铅 镉 PN-ISO 8288:2002 metoda A","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"废水、水"},{"_id":"6a5dc9b1f1c10c8ce825bbf4","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Ścieki, Woda","test_object_en":"Wastewater, Water","methodology":"Stężenie chromu ogólnego","methodology_en":"Total chromium concentration","parameters":[{"name":"Zakres","range":"(0,05 – 100) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,05 – 100) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"technique_en":"Flame atomic absorption spectrometry (FAAS)","computed":[],"computed_en":[],"activity":"Stężenie chromu ogólnego\nZakres (0,05 – 100) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-EN 1233:2000 punkt 3","norm_bases":["PN-EN 1233:2000 punkt 3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, Woda Stężenie chromu ogólnego\nZakres (0,05 – 100) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN 1233:2000 punkt 3 Scieki, Woda Stezenie chromu ogolnego\nZakres (0,05 – 100) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN 1233:2000 punkt 3","categories":["water"],"row_index":62,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, Water Total chromium concentration Flame atomic absorption spectrometry (FAAS) Range PN-EN 1233:2000 punkt 3","parameters_zh":[{"name":"范围","range":"(0,05 – 100) mg/l"}],"search_zh":"废水、水 总铬浓度 火焰原子吸收光谱法（FAAS） 范围 PN-EN 1233:2000 punkt 3","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"废水、水","methodology_zh":"总铬浓度"},{"_id":"6a5dc9b1f1c10c8ce825bbf5","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Ścieki, Woda","test_object_en":"Wastewater, Water","methodology":"Stężenie pierwiastków:","methodology_en":"Element concentrations:","parameters":[{"name":"srebro","range":"(0,002 – 0,200) mg/l"},{"name":"arsen","range":"(0,010 – 0,200) mg/l"},{"name":"kadm","range":"(0,0005 – 0,400) mg/l"},{"name":"chrom ogólny","range":"(0,002 – 100) mg/l"},{"name":"miedź","range":"(0,010 – 50,0) mg/l"},{"name":"żelazo","range":"(0,040 – 100) mg/l"},{"name":"nikiel","range":"(0,010 – 5,00) mg/l"},{"name":"ołów","range":"(0,010 – 5,00) mg/l"},{"name":"wanad","range":"(0,010 – 4,00) mg/l"},{"name":"cynk","range":"(0,020 – 100) mg/l"}],"parameters_en":[{"name":"silver","range":"(0,002 – 0,200) mg/l"},{"name":"arsenic","range":"(0,010 – 0,200) mg/l"},{"name":"cadmium","range":"(0,0005 – 0,400) mg/l"},{"name":"total chromium","range":"(0,002 – 100) mg/l"},{"name":"copper","range":"(0,010 – 50,0) mg/l"},{"name":"iron","range":"(0,040 – 100) mg/l"},{"name":"nickel","range":"(0,010 – 5,00) mg/l"},{"name":"lead","range":"(0,010 – 5,00) mg/l"},{"name":"vanadium","range":"(0,010 – 4,00) mg/l"},{"name":"zinc","range":"(0,020 – 100) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","computed":[],"computed_en":[],"activity":"Stężenie pierwiastków:\nZakres:\nsrebro (0,002 – 0,200) mg/l\narsen (0,010 – 0,200) mg/l\nkadm (0,0005 – 0,400) mg/l\nchrom ogólny (0,002 – 100) mg/l\nmiedź (0,010 – 50,0) mg/l\nżelazo (0,040 – 100) mg/l\nnikiel (0,010 – 5,00) mg/l\nołów (0,010 – 5,00) mg/l\nwanad (0,010 – 4,00) mg/l\ncynk (0,020 – 100) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, Woda Stężenie pierwiastków:\nZakres:\nsrebro (0,002 – 0,200) mg/l\narsen (0,010 – 0,200) mg/l\nkadm (0,0005 – 0,400) mg/l\nchrom ogólny (0,002 – 100) mg/l\nmiedź (0,010 – 50,0) mg/l\nżelazo (0,040 – 100) mg/l\nnikiel (0,010 – 5,00) mg/l\nołów (0,010 – 5,00) mg/l\nwanad (0,010 – 4,00) mg/l\ncynk (0,020 – 100) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Scieki, Woda Stezenie pierwiastkow:\nZakres:\nsrebro (0,002 – 0,200) mg/l\narsen (0,010 – 0,200) mg/l\nkadm (0,0005 – 0,400) mg/l\nchrom ogolny (0,002 – 100) mg/l\nmiedz (0,010 – 50,0) mg/l\nzelazo (0,040 – 100) mg/l\nnikiel (0,010 – 5,00) mg/l\nolow (0,010 – 5,00) mg/l\nwanad (0,010 – 4,00) mg/l\ncynk (0,020 – 100) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["water","materials"],"row_index":63,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, Water Element concentrations: Inductively coupled plasma optical emission spectrometry (ICP-OES) silver arsenic cadmium total chromium copper iron nickel lead vanadium zinc PN-EN ISO 11885:2009","methodology_zh":"元素浓度：","parameters_zh":[{"name":"银","range":"(0,002 – 0,200) mg/l"},{"name":"砷","range":"(0,010 – 0,200) mg/l"},{"name":"镉","range":"(0,0005 – 0,400) mg/l"},{"name":"总铬","range":"(0,002 – 100) mg/l"},{"name":"铜","range":"(0,010 – 50,0) mg/l"},{"name":"铁","range":"(0,040 – 100) mg/l"},{"name":"镍","range":"(0,010 – 5,00) mg/l"},{"name":"铅","range":"(0,010 – 5,00) mg/l"},{"name":"钒","range":"(0,010 – 4,00) mg/l"},{"name":"锌","range":"(0,020 – 100) mg/l"}],"search_zh":"废水、水 元素浓度： 电感耦合等离子体原子发射光谱法（ICP-OES） 银 砷 镉 总铬 铜 铁 镍 铅 钒 锌 PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"废水、水"},{"_id":"6a5dc9b1f1c10c8ce825bbf6","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Ścieki, Woda","test_object_en":"Wastewater, Water","methodology":"Stężenie rtęci","methodology_en":"Mercury concentration","parameters":[{"name":"Zakres","range":"(0,0005 – 0,100) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,0005 – 0,100) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej techniką zimnych par (CV-ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej techniką zimnych par (CV-ICP-OES)"],"technique_en":"Inductively coupled plasma atomic emission spectrometry with the cold vapour technique (CV-ICP-OES)","computed":[],"computed_en":[],"activity":"Stężenie rtęci\nZakres (0,0005 – 0,100) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej techniką zimnych par (CV-ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, Woda Stężenie rtęci\nZakres (0,0005 – 0,100) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej techniką zimnych par (CV-ICP-OES) PN-EN ISO 11885:2009 Scieki, Woda Stezenie rteci\nZakres (0,0005 – 0,100) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej technika zimnych par (CV-ICP-OES) PN-EN ISO 11885:2009","categories":["water"],"row_index":64,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, Water Mercury concentration Inductively coupled plasma atomic emission spectrometry with the cold vapour technique (CV-ICP-OES) Range PN-EN ISO 11885:2009","methodology_zh":"汞浓度","parameters_zh":[{"name":"范围","range":"(0,0005 – 0,100) mg/l"}],"search_zh":"废水、水 汞浓度 范围 PN-EN ISO 11885:2009","test_object_zh":"废水、水"},{"_id":"6a5dc9b1f1c10c8ce825bbf7","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Ścieki, Woda","test_object_en":"Wastewater, Water","methodology":"Stężenie rtęci","methodology_en":"Mercury concentration","parameters":[{"name":"Zakres","range":"(0,0005 – 0,100) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,0005 – 0,100) mg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej techniką zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej techniką zimnych par (CVAAS)"],"technique_en":"Cold vapour atomic absorption spectrometry (CVAAS)","computed":[],"computed_en":[],"activity":"Stężenie rtęci\nZakres (0,0005 – 0,100) mg/l\nMetoda absorpcyjnej spektrometrii atomowej techniką zimnych par (CVAAS)","reference":"PN-EN ISO 12846:2012 punkt 7 +Ap1:2016-07","norm_bases":["PN-EN ISO 12846:2012 punkt 7 +Ap1:2016-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, Woda Stężenie rtęci\nZakres (0,0005 – 0,100) mg/l\nMetoda absorpcyjnej spektrometrii atomowej techniką zimnych par (CVAAS) PN-EN ISO 12846:2012 punkt 7 +Ap1:2016-07 Scieki, Woda Stezenie rteci\nZakres (0,0005 – 0,100) mg/l\nMetoda absorpcyjnej spektrometrii atomowej technika zimnych par (CVAAS) PN-EN ISO 12846:2012 punkt 7 +Ap1:2016-07","categories":["water"],"row_index":65,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, Water Mercury concentration Cold vapour atomic absorption spectrometry (CVAAS) Range PN-EN ISO 12846:2012 punkt 7 +Ap1:2016-07","methodology_zh":"汞浓度","parameters_zh":[{"name":"范围","range":"(0,0005 – 0,100) mg/l"}],"search_zh":"废水、水 汞浓度 范围 PN-EN ISO 12846:2012 punkt 7 +Ap1:2016-07","test_object_zh":"废水、水"},{"_id":"6a5dc9b1f1c10c8ce825bbf8","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"pH w H2O","methodology_en":"pH in H2O","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH w H2O\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe pH w H2O\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 Osady sciekowe pH w H2O\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["water"],"row_index":66,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge pH in H2O Potentiometric method Range PN-EN ISO 10390:2022-09","methodology_zh":"水中 pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"污泥 水中 pH 值 电位法 范围 PN-EN ISO 10390:2022-09","technique_zh":"电位法","test_object_zh":"污泥"},{"_id":"6a5dc9b1f1c10c8ce825bbf9","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Zawartość suchej pozostałości/wody","methodology_en":"Dry residue/water content","parameters":[{"name":"Zakres","range":"(1,0 – 98,0) %"},{"name":"Zakres","range":"(2,0 – 99,0) %"}],"parameters_en":[{"name":"Range","range":"(1,0 – 98,0) %"},{"name":"Range","range":"(2,0 – 99,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość suchej pozostałości/wody\nZakres:\nZakres (1,0 – 98,0) %\nZakres (2,0 – 99,0) %\nMetoda wagowa","reference":"PN-EN 15934:2013-02","norm_bases":["PN-EN 15934:2013-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Zawartość suchej pozostałości/wody\nZakres:\nZakres (1,0 – 98,0) %\nZakres (2,0 – 99,0) %\nMetoda wagowa PN-EN 15934:2013-02 Osady sciekowe Zawartosc suchej pozostalosci/wody\nZakres:\nZakres (1,0 – 98,0) %\nZakres (2,0 – 99,0) %\nMetoda wagowa PN-EN 15934:2013-02","categories":["water"],"row_index":67,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge Dry residue/water content Gravimetric method Range Range PN-EN 15934:2013-02","parameters_zh":[{"name":"范围","range":"(1,0 – 98,0) %"},{"name":"范围","range":"(2,0 – 99,0) %"}],"search_zh":"污泥 重量法 范围 范围 PN-EN 15934:2013-02","technique_zh":"重量法","test_object_zh":"污泥"},{"_id":"6a5dc9b1f1c10c8ce825bbfa","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Zawartość związków organicznych (straty przy prażeniu)","methodology_en":"Content of organic compounds (loss on ignition)","parameters":[{"name":"Zakres","range":"(10,0 – 80,0) %"}],"parameters_en":[{"name":"Range","range":"(10,0 – 80,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość związków organicznych (straty przy prażeniu)\nZakres (10,0 – 80,0) %\nMetoda wagowa","reference":"PN-EN 15935:2022-01 z wył. pkt 7.4, 8.2","norm_bases":["PN-EN 15935:2022-01 z wył. pkt 7.4, 8.2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Zawartość związków organicznych (straty przy prażeniu)\nZakres (10,0 – 80,0) %\nMetoda wagowa PN-EN 15935:2022-01 z wył. pkt 7.4, 8.2 Osady sciekowe Zawartosc zwiazkow organicznych (straty przy prazeniu)\nZakres (10,0 – 80,0) %\nMetoda wagowa PN-EN 15935:2022-01 z wyl. pkt 7.4, 8.2","categories":["water"],"row_index":68,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge Content of organic compounds (loss on ignition) Gravimetric method Range PN-EN 15935:2022-01 z wył. pkt 7.4, 8.2","parameters_zh":[{"name":"范围","range":"(10,0 – 80,0) %"}],"search_zh":"污泥 重量法 范围 PN-EN 15935:2022-01 z wył. pkt 7.4, 8.2","technique_zh":"重量法","test_object_zh":"污泥"},{"_id":"6a5dc9b1f1c10c8ce825bbfb","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Zawartość azotu Kjeldahla","methodology_en":"Kjeldahl nitrogen content","parameters":[{"name":"Zakres","range":"(0,50 – 10,0) %"}],"parameters_en":[{"name":"Range","range":"(0,50 – 10,0) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Zawartość azotu Kjeldahla\nZakres (0,50 – 10,0) %\nMetoda miareczkowa","reference":"PN-EN 13342:2002","norm_bases":["PN-EN 13342:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Zawartość azotu Kjeldahla\nZakres (0,50 – 10,0) %\nMetoda miareczkowa PN-EN 13342:2002 Osady sciekowe Zawartosc azotu Kjeldahla\nZakres (0,50 – 10,0) %\nMetoda miareczkowa PN-EN 13342:2002","categories":["water"],"row_index":69,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge Kjeldahl nitrogen content Titrimetric method Range PN-EN 13342:2002","parameters_zh":[{"name":"范围","range":"(0,50 – 10,0) %"}],"search_zh":"污泥 凯氏氮含量 滴定法 范围 PN-EN 13342:2002","technique_zh":"滴定法","test_object_zh":"污泥","methodology_zh":"凯氏氮含量"},{"_id":"6a5dc9b1f1c10c8ce825bbfc","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Suma zawartości azotu amonowego i aminowego (azot Kjeldahla)","methodology_en":"Sum of ammonium and amino nitrogen content (Kjeldahl nitrogen)","parameters":[{"name":"Zakres","range":"(0,50 – 10,0) %"}],"parameters_en":[{"name":"Range","range":"(0,50 – 10,0) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Suma zawartości azotu amonowego i aminowego (azot Kjeldahla)\nZakres (0,50 – 10,0) %\nMetoda miareczkowa","reference":"PN-EN 16169:2012","norm_bases":["PN-EN 16169:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Suma zawartości azotu amonowego i aminowego (azot Kjeldahla)\nZakres (0,50 – 10,0) %\nMetoda miareczkowa PN-EN 16169:2012 Osady sciekowe Suma zawartosci azotu amonowego i aminowego (azot Kjeldahla)\nZakres (0,50 – 10,0) %\nMetoda miareczkowa PN-EN 16169:2012","categories":["water"],"row_index":70,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge Sum of ammonium and amino nitrogen content (Kjeldahl nitrogen) Titrimetric method Range PN-EN 16169:2012","parameters_zh":[{"name":"范围","range":"(0,50 – 10,0) %"}],"search_zh":"污泥 滴定法 范围 PN-EN 16169:2012","technique_zh":"滴定法","test_object_zh":"污泥"},{"_id":"6a5dc9b1f1c10c8ce825bbfd","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Zawartość azotu amonowego","methodology_en":"Ammonium nitrogen content","parameters":[{"name":"Zakres","range":"(0,02 – 10,0) %"}],"parameters_en":[{"name":"Range","range":"(0,02 – 10,0) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Zawartość azotu amonowego\nZakres (0,02 – 10,0) %\nMetoda miareczkowa","reference":"PN-EN 14671:2007","norm_bases":["PN-EN 14671:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Zawartość azotu amonowego\nZakres (0,02 – 10,0) %\nMetoda miareczkowa PN-EN 14671:2007 Osady sciekowe Zawartosc azotu amonowego\nZakres (0,02 – 10,0) %\nMetoda miareczkowa PN-EN 14671:2007","categories":["water"],"row_index":71,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge Ammonium nitrogen content Titrimetric method Range PN-EN 14671:2007","parameters_zh":[{"name":"范围","range":"(0,02 – 10,0) %"}],"search_zh":"污泥 氨氮含量 滴定法 范围 PN-EN 14671:2007","technique_zh":"滴定法","test_object_zh":"污泥","methodology_zh":"氨氮含量"},{"_id":"6a5dc9b1f1c10c8ce825bbfe","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Zawartość fosforu ogólnego","methodology_en":"Total phosphorus content","parameters":[{"name":"Zakres","range":"(0,060 - 5,00) %"}],"parameters_en":[{"name":"Range","range":"(0,060 - 5,00) %"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Zawartość fosforu ogólnego\nZakres (0,060 - 5,00) %\nMetoda spektrofotometryczna","reference":"PB-04 wyd. 3 z dnia 22.08.2011","norm_bases":["PB-04 wyd. 3 z dnia 22.08.2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Zawartość fosforu ogólnego\nZakres (0,060 - 5,00) %\nMetoda spektrofotometryczna PB-04 wyd. 3 z dnia 22.08.2011 Osady sciekowe Zawartosc fosforu ogolnego\nZakres (0,060 - 5,00) %\nMetoda spektrofotometryczna PB-04 wyd. 3 z dnia 22.08.2011","categories":["water"],"row_index":72,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge Total phosphorus content Spectrophotometric method Range PB-04 wyd. 3 z dnia 22.08.2011","parameters_zh":[{"name":"范围","range":"(0,060 - 5,00) %"}],"search_zh":"污泥 总磷含量 分光光度法 范围 PB-04 wyd. 3 z dnia 22.08.2011","technique_zh":"分光光度法","test_object_zh":"污泥","methodology_zh":"总磷含量"},{"_id":"6a5dc9b1f1c10c8ce825bbff","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Zawartość pierwiastków:","methodology_en":"Element content:","parameters":[{"name":"magnez","range":"(0,12 - 1,25) %"},{"name":"wapń","range":"(1,25 - 12,5) %"}],"parameters_en":[{"name":"magnesium","range":"(0,12 - 1,25) %"},{"name":"calcium","range":"(1,25 - 12,5) %"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"technique_en":"Flame atomic absorption spectrometry (FAAS)","computed":[],"computed_en":[],"activity":"Zawartość pierwiastków:\nZakres:\nmagnez (0,12 - 1,25) %\nwapń (1,25 - 12,5) %\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PB-20 wyd. 2 z dnia 25.08.2011","norm_bases":["PB-20 wyd. 2 z dnia 25.08.2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Zawartość pierwiastków:\nZakres:\nmagnez (0,12 - 1,25) %\nwapń (1,25 - 12,5) %\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB-20 wyd. 2 z dnia 25.08.2011 Osady sciekowe Zawartosc pierwiastkow:\nZakres:\nmagnez (0,12 - 1,25) %\nwapn (1,25 - 12,5) %\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB-20 wyd. 2 z dnia 25.08.2011","categories":["water"],"row_index":73,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge Element content: Flame atomic absorption spectrometry (FAAS) magnesium calcium PB-20 wyd. 2 z dnia 25.08.2011","methodology_zh":"元素含量：","search_zh":"污泥 元素含量： 火焰原子吸收光谱法（FAAS） 镁 钙 PB-20 wyd. 2 z dnia 25.08.2011","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"污泥","parameters_zh":[{"name":"镁","range":"(0,12 - 1,25) %"},{"name":"钙","range":"(1,25 - 12,5) %"}]},{"_id":"6a5dc9b1f1c10c8ce825bc00","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Zawartość pierwiastków:","methodology_en":"Element content:","parameters":[{"name":"cynk","range":"(250 - 4000) mg/kg"},{"name":"kadm","range":"(1,25 - 20,0) mg/kg"},{"name":"miedź","range":"(50 - 600) mg/kg"},{"name":"nikiel","range":"(5,00 - 80,0) mg/kg"},{"name":"ołów","range":"(12,5 - 200) mg/kg"},{"name":"chrom ogólny","range":"(25,0 - 400) mg/kg"}],"parameters_en":[{"name":"zinc","range":"(250 - 4000) mg/kg"},{"name":"cadmium","range":"(1,25 - 20,0) mg/kg"},{"name":"copper","range":"(50 - 600) mg/kg"},{"name":"nickel","range":"(5,00 - 80,0) mg/kg"},{"name":"lead","range":"(12,5 - 200) mg/kg"},{"name":"total chromium","range":"(25,0 - 400) mg/kg"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"technique_en":"Flame atomic absorption spectrometry (FAAS)","computed":[],"computed_en":[],"activity":"Zawartość pierwiastków:\nZakres:\ncynk (250 - 4000) mg/kg\nkadm (1,25 - 20,0) mg/kg\nmiedź (50 - 600) mg/kg\nnikiel (5,00 - 80,0) mg/kg\nołów (12,5 - 200) mg/kg\nchrom ogólny (25,0 - 400) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PB-16 wyd. 3 z dnia 25.08.2011","norm_bases":["PB-16 wyd. 3 z dnia 25.08.2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Zawartość pierwiastków:\nZakres:\ncynk (250 - 4000) mg/kg\nkadm (1,25 - 20,0) mg/kg\nmiedź (50 - 600) mg/kg\nnikiel (5,00 - 80,0) mg/kg\nołów (12,5 - 200) mg/kg\nchrom ogólny (25,0 - 400) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB-16 wyd. 3 z dnia 25.08.2011 Osady sciekowe Zawartosc pierwiastkow:\nZakres:\ncynk (250 - 4000) mg/kg\nkadm (1,25 - 20,0) mg/kg\nmiedz (50 - 600) mg/kg\nnikiel (5,00 - 80,0) mg/kg\nolow (12,5 - 200) mg/kg\nchrom ogolny (25,0 - 400) mg/kg\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB-16 wyd. 3 z dnia 25.08.2011","categories":["water","materials"],"row_index":74,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge Element content: Flame atomic absorption spectrometry (FAAS) zinc cadmium copper nickel lead total chromium PB-16 wyd. 3 z dnia 25.08.2011","methodology_zh":"元素含量：","parameters_zh":[{"name":"锌","range":"(250 - 4000) mg/kg"},{"name":"镉","range":"(1,25 - 20,0) mg/kg"},{"name":"铜","range":"(50 - 600) mg/kg"},{"name":"镍","range":"(5,00 - 80,0) mg/kg"},{"name":"铅","range":"(12,5 - 200) mg/kg"},{"name":"总铬","range":"(25,0 - 400) mg/kg"}],"search_zh":"污泥 元素含量： 火焰原子吸收光谱法（FAAS） 锌 镉 铜 镍 铅 总铬 PB-16 wyd. 3 z dnia 25.08.2011","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"污泥"},{"_id":"6a5dc9b1f1c10c8ce825bc01","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Zawartość pierwiastków:","methodology_en":"Element content:","parameters":[{"name":"kadm","range":"(1,25 - 50,0) mg/kg"},{"name":"chrom ogólny","range":"(25,0 - 2500) mg/kg"},{"name":"miedź","range":"(50 - 2000) mg/kg"},{"name":"nikiel","range":"(5,00 - 500) mg/kg"},{"name":"ołów","range":"(12,5 - 1500) mg/kg"},{"name":"cynk","range":"(250 - 5000) mg/kg"},{"name":"wapń","range":"(1,25 - 12,5) %"},{"name":"magnez","range":"(0,12 - 1,25) %"},{"name":"fosfor ogólny","range":"(0,060 - 5,00) %"},{"name":"rtęć","range":"(0,80 – 25,0) mg/kg"}],"parameters_en":[{"name":"cadmium","range":"(1,25 - 50,0) mg/kg"},{"name":"total chromium","range":"(25,0 - 2500) mg/kg"},{"name":"copper","range":"(50 - 2000) mg/kg"},{"name":"nickel","range":"(5,00 - 500) mg/kg"},{"name":"lead","range":"(12,5 - 1500) mg/kg"},{"name":"zinc","range":"(250 - 5000) mg/kg"},{"name":"calcium","range":"(1,25 - 12,5) %"},{"name":"magnesium","range":"(0,12 - 1,25) %"},{"name":"total phosphorus","range":"(0,060 - 5,00) %"},{"name":"mercury","range":"(0,80 – 25,0) mg/kg"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","computed":[],"computed_en":[],"activity":"Zawartość pierwiastków:\nZakres:\nkadm (1,25 - 50,0) mg/kg\nchrom ogólny (25,0 - 2500) mg/kg\nmiedź (50 - 2000) mg/kg\nnikiel (5,00 - 500) mg/kg\nołów (12,5 - 1500) mg/kg\ncynk (250 - 5000) mg/kg\nwapń (1,25 - 12,5) %\nmagnez (0,12 - 1,25) %\nfosfor ogólny (0,060 - 5,00) %\nrtęć (0,80 – 25,0) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 22036:2024-07","norm_bases":["PN-EN ISO 22036:2024-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Zawartość pierwiastków:\nZakres:\nkadm (1,25 - 50,0) mg/kg\nchrom ogólny (25,0 - 2500) mg/kg\nmiedź (50 - 2000) mg/kg\nnikiel (5,00 - 500) mg/kg\nołów (12,5 - 1500) mg/kg\ncynk (250 - 5000) mg/kg\nwapń (1,25 - 12,5) %\nmagnez (0,12 - 1,25) %\nfosfor ogólny (0,060 - 5,00) %\nrtęć (0,80 – 25,0) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 22036:2024-07 Osady sciekowe Zawartosc pierwiastkow:\nZakres:\nkadm (1,25 - 50,0) mg/kg\nchrom ogolny (25,0 - 2500) mg/kg\nmiedz (50 - 2000) mg/kg\nnikiel (5,00 - 500) mg/kg\nolow (12,5 - 1500) mg/kg\ncynk (250 - 5000) mg/kg\nwapn (1,25 - 12,5) %\nmagnez (0,12 - 1,25) %\nfosfor ogolny (0,060 - 5,00) %\nrtec (0,80 – 25,0) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 22036:2024-07","categories":["water","materials"],"row_index":75,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge Element content: Inductively coupled plasma optical emission spectrometry (ICP-OES) cadmium total chromium copper nickel lead zinc calcium magnesium total phosphorus mercury PN-EN ISO 22036:2024-07","methodology_zh":"元素含量：","parameters_zh":[{"name":"镉","range":"(1,25 - 50,0) mg/kg"},{"name":"总铬","range":"(25,0 - 2500) mg/kg"},{"name":"铜","range":"(50 - 2000) mg/kg"},{"name":"镍","range":"(5,00 - 500) mg/kg"},{"name":"铅","range":"(12,5 - 1500) mg/kg"},{"name":"锌","range":"(250 - 5000) mg/kg"},{"name":"钙","range":"(1,25 - 12,5) %"},{"name":"镁","range":"(0,12 - 1,25) %"},{"name":"总磷","range":"(0,060 - 5,00) %"},{"name":"汞","range":"(0,80 – 25,0) mg/kg"}],"search_zh":"污泥 元素含量： 电感耦合等离子体原子发射光谱法（ICP-OES） 镉 总铬 铜 镍 铅 锌 钙 镁 总磷 汞 PN-EN ISO 22036:2024-07","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"污泥"},{"_id":"6a5dc9b1f1c10c8ce825bc02","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Zawartość rtęci","methodology_en":"Mercury content","parameters":[{"name":"Zakres","range":"(0,80 - 8,0) mg/kg"}],"parameters_en":[{"name":"Range","range":"(0,80 - 8,0) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej techniką zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej techniką zimnych par (CVAAS)"],"technique_en":"Cold vapour atomic absorption spectrometry (CVAAS)","computed":[],"computed_en":[],"activity":"Zawartość rtęci\nZakres (0,80 - 8,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej techniką zimnych par (CVAAS)","reference":"PB-17 wyd. 3 z dnia 25.08.2011","norm_bases":["PB-17 wyd. 3 z dnia 25.08.2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Zawartość rtęci\nZakres (0,80 - 8,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej techniką zimnych par (CVAAS) PB-17 wyd. 3 z dnia 25.08.2011 Osady sciekowe Zawartosc rteci\nZakres (0,80 - 8,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej technika zimnych par (CVAAS) PB-17 wyd. 3 z dnia 25.08.2011","categories":["water"],"row_index":76,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge Mercury content Cold vapour atomic absorption spectrometry (CVAAS) Range PB-17 wyd. 3 z dnia 25.08.2011","methodology_zh":"汞含量","parameters_zh":[{"name":"范围","range":"(0,80 - 8,0) mg/kg"}],"search_zh":"污泥 汞含量 范围 PB-17 wyd. 3 z dnia 25.08.2011","test_object_zh":"污泥"},{"_id":"6a5dc9b1f1c10c8ce825bc03","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Obecność bakterii z rodzaju, Salmonella w 100 g osadu","methodology_en":"Presence of bacteria of the genus, Salmonella in 100 g of sludge","parameters":[],"parameters_en":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"technique_en":"Culture method with biochemical and serological confirmation","computed":[],"computed_en":[],"activity":"Obecność bakterii z rodzaju, Salmonella w 100 g osadu\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PB-18 wyd. 3 z dnia 03.02.2025","norm_bases":["PB-18 wyd. 3 z dnia 03.02.2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Obecność bakterii z rodzaju, Salmonella w 100 g osadu\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB-18 wyd. 3 z dnia 03.02.2025 Osady sciekowe Obecnosc bakterii z rodzaju, Salmonella w 100 g osadu\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB-18 wyd. 3 z dnia 03.02.2025","categories":["microbiology","water"],"row_index":77,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge Presence of bacteria of the genus, Salmonella in 100 g of sludge Culture method with biochemical and serological confirmation PB-18 wyd. 3 z dnia 03.02.2025","search_zh":"污泥 培养法结合生化与血清学确认 PB-18 wyd. 3 z dnia 03.02.2025","technique_zh":"培养法结合生化与血清学确认","test_object_zh":"污泥"},{"_id":"6a5dc9b1f1c10c8ce825bc04","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Obecność żywych jaj pasożytów jelitowych Ascaris sp., Toxocara sp., Trichuris sp.","methodology_en":"Presence of live eggs of intestinal parasites Ascaris sp., Toxocara sp., Trichuris sp.","parameters":[],"parameters_en":[],"technique":"Metoda flotacji, mikroskopowa","techniques":["Metoda flotacji, mikroskopowa"],"technique_en":"Flotation method, microscopic","computed":[],"computed_en":[],"activity":"Obecność żywych jaj pasożytów jelitowych Ascaris sp., Toxocara sp., Trichuris sp.\nMetoda flotacji, mikroskopowa","reference":"PN-Z-19005:2018-10","norm_bases":["PN-Z-19005:2018-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Obecność żywych jaj pasożytów jelitowych Ascaris sp., Toxocara sp., Trichuris sp.\nMetoda flotacji, mikroskopowa PN-Z-19005:2018-10 Osady sciekowe Obecnosc zywych jaj pasozytow jelitowych Ascaris sp., Toxocara sp., Trichuris sp.\nMetoda flotacji, mikroskopowa PN-Z-19005:2018-10","categories":["water"],"row_index":78,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge Presence of live eggs of intestinal parasites Ascaris sp., Toxocara sp., Trichuris sp. Flotation method, microscopic PN-Z-19005:2018-10","search_zh":"污泥 浮选显微镜法 PN-Z-19005:2018-10","test_object_zh":"污泥","technique_zh":"浮选显微镜法"},{"_id":"6a5dc9b1f1c10c8ce825bc05","lab_id":"69ad52a3de79e566650fb213","country":"PL","accr_number":"AB 415","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Liczba żywych jaj pasożytów jelitowych Ascaris sp., Toxocara sp., Trichuris sp.","methodology_en":"Count of viable eggs of intestinal parasites Ascaris sp., Toxocara sp., Trichuris sp.","parameters":[],"parameters_en":[],"technique":"Metoda flotacji, mikroskopowa","techniques":["Metoda flotacji, mikroskopowa"],"technique_en":"Flotation method, microscopic","computed":[],"computed_en":[],"activity":"Liczba żywych jaj pasożytów jelitowych Ascaris sp., Toxocara sp., Trichuris sp.\nMetoda flotacji, mikroskopowa","reference":"PN-Z-19005:2018-10","norm_bases":["PN-Z-19005:2018-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Liczba żywych jaj pasożytów jelitowych Ascaris sp., Toxocara sp., Trichuris sp.\nMetoda flotacji, mikroskopowa PN-Z-19005:2018-10 Osady sciekowe Liczba zywych jaj pasozytow jelitowych Ascaris sp., Toxocara sp., Trichuris sp.\nMetoda flotacji, mikroskopowa PN-Z-19005:2018-10","categories":["water"],"row_index":79,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge Count of viable eggs of intestinal parasites Ascaris sp., Toxocara sp., Trichuris sp. Flotation method, microscopic PN-Z-19005:2018-10","search_zh":"污泥 浮选显微镜法 PN-Z-19005:2018-10","test_object_zh":"污泥","technique_zh":"浮选显微镜法"}],"has_pdf":true}