{"lab":{"_id":"69ad52a3de79e566650fb205","accr_number":"AB 406","country":"PL","accr_body":"PCA","address":"LABORATORIUM CHEMICZNE, ul. Tytoniowa 16, 16-300 Augustów","categories":["water"],"city":"Augustów","imported_at":"2026-03-08T10:42:43.265Z","methods_count":7,"name":"BRITISH-AMERICAN TOBACCO POLSKA S. A.","parse_status":"parsed","parse_version":2,"pdf_files":["AB_406.pdf"],"scope_summary":"","search_text":"british-american tobacco polska s. a. laboratorium chemiczne, ul. tytoniowa 16, 16-300 augustów other water","status":"active","updated_at":"2026-03-08T14:51:14.216Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-09-11T00:31:50.211Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20406,podmiot.html","fields_of_testing":[{"codes":"C/24/P","pl":"Badania chemiczne i pobieranie próbek wyrobów tytoniowych","en":"Chemical tests and sampling of tobacco products"},{"codes":"N/24/P","pl":"Badanie własności fizycznych i pobieranie próbek wyrobów tytoniowych","en":"Tests of physical properties and sampling of tobacco products"}],"issue":{"no":"22","date":"09.09.2026"},"parse_date":"2026-09-11T00:31:50.211Z","parse_source":"agent-claude-code","map_coord":[53.85478,23.01545],"map_geo":"nominatim-street","has_en":true,"category_counts":{"other":6,"water":1},"category_scores":{"other":5.14,"water":0.14},"has_zh":true,"lab_locations":[{"code":null,"name":"BRITISH-AMERICAN TOBACCO POLSKA S. A.","street":"ul. Tytoniowa 16","postal_code":"16-300","city":"Augustów","is_hq":true,"address":"ul. Tytoniowa 16, 16-300 Augustów","site":"16-300|tytoniowa16"},{"code":null,"name":"LABORATORIUM CHEMICZNE","street":"ul. Tytoniowa 16","postal_code":"","city":"","is_hq":false,"address":"ul. Tytoniowa 16","site":"|tytoniowa16"}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/9/10/c4b852cd3a38d7a9ec92954d5d74e1e4/AB%20406.pdf"},"methods":[{"_id":"6aa34bf6576d0c1fdcb81cb2","lab_id":"69ad52a3de79e566650fb205","country":"PL","accr_number":"AB 406","accr_body":"PCA","test_object":"Papierosy","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"ISO 8243:2013","norm_bases":["ISO 8243:2013"],"lab_section":"Laboratorium Chemiczne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Papierosy Pobieranie próbek do badań chemicznych i fizycznych ISO 8243:2013 Papierosy Pobieranie probek do badan chemicznych i fizycznych ISO 8243:2013","categories":["other"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6aa34bf6576d0c1fdcb81cb3","lab_id":"69ad52a3de79e566650fb205","country":"PL","accr_number":"AB 406","accr_body":"PCA","test_object":"Papierosy","methodology":"Zawartość surowego kondensatu dymu na papieros","parameters":[{"name":"Zakres","range":"(1,00 – 20,00) mg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość surowego kondensatu dymu na papieros\nZakres (1,00 – 20,00) mg\nMetoda wagowa","reference":"ISO 4387:2019","norm_bases":["ISO 4387:2019"],"lab_section":"Laboratorium Chemiczne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Papierosy Zawartość surowego kondensatu dymu na papieros\nZakres (1,00 – 20,00) mg\nMetoda wagowa ISO 4387:2019 Papierosy Zawartosc surowego kondensatu dymu na papieros\nZakres (1,00 – 20,00) mg\nMetoda wagowa ISO 4387:2019","categories":["other"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6aa34bf6576d0c1fdcb81cb4","lab_id":"69ad52a3de79e566650fb205","country":"PL","accr_number":"AB 406","accr_body":"PCA","test_object":"Papierosy","methodology":"Zawartość tlenku węgla na papieros","parameters":[{"name":"Zakres","range":"(2,00 – 15,00) mg"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"computed":[],"activity":"Zawartość tlenku węgla na papieros\nZakres (2,00 – 15,00) mg\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"ISO 8454:2024","norm_bases":["ISO 8454:2024"],"lab_section":"Laboratorium Chemiczne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Papierosy Zawartość tlenku węgla na papieros\nZakres (2,00 – 15,00) mg\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) ISO 8454:2024 Papierosy Zawartosc tlenku wegla na papieros\nZakres (2,00 – 15,00) mg\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) ISO 8454:2024","categories":["other"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6aa34bf6576d0c1fdcb81cb5","lab_id":"69ad52a3de79e566650fb205","country":"PL","accr_number":"AB 406","accr_body":"PCA","test_object":"Papierosy","methodology":"Zawartość nikotyny na papieros","parameters":[{"name":"Zakres","range":"(0,100 – 2,000) mg"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość nikotyny na papieros\nZakres (0,100 – 2,000) mg\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"ISO 10315:2021","norm_bases":["ISO 10315:2021"],"lab_section":"Laboratorium Chemiczne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Papierosy Zawartość nikotyny na papieros\nZakres (0,100 – 2,000) mg\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) ISO 10315:2021 Papierosy Zawartosc nikotyny na papieros\nZakres (0,100 – 2,000) mg\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) ISO 10315:2021","categories":["other"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6aa34bf6576d0c1fdcb81cb6","lab_id":"69ad52a3de79e566650fb205","country":"PL","accr_number":"AB 406","accr_body":"PCA","test_object":"Papierosy","methodology":"Zawartość wody na papieros","parameters":[{"name":"Zakres","range":"(0,200 – 2,500) mg"}],"technique":"Metoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD)","techniques":["Metoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD)"],"computed":[],"activity":"Zawartość wody na papieros\nZakres (0,200 – 2,500) mg\nMetoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD)","reference":"ISO 10362-1:2019","norm_bases":["ISO 10362-1:2019"],"lab_section":"Laboratorium Chemiczne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Papierosy Zawartość wody na papieros\nZakres (0,200 – 2,500) mg\nMetoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD) ISO 10362-1:2019 Papierosy Zawartosc wody na papieros\nZakres (0,200 – 2,500) mg\nMetoda chromatografii gazowej z detekcja termokonduktometryczna (GC-TCD) ISO 10362-1:2019","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6aa34bf6576d0c1fdcb81cb7","lab_id":"69ad52a3de79e566650fb205","country":"PL","accr_number":"AB 406","accr_body":"PCA","test_object":"Papierosy","methodology":"Zawartość substancji smolistych (NFDPM) na papieros","parameters":[{"name":"Zakres","range":"(1,00 – 15,00) mg"},{"name":"(z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość substancji smolistych (NFDPM) na papieros\nZakres:\nZakres (1,00 – 15,00) mg\n(z obliczeń)","reference":"ISO 4387:2019","norm_bases":["ISO 4387:2019"],"lab_section":"Laboratorium Chemiczne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Papierosy Zawartość substancji smolistych (NFDPM) na papieros\nZakres:\nZakres (1,00 – 15,00) mg\n(z obliczeń) ISO 4387:2019 Papierosy Zawartosc substancji smolistych (NFDPM) na papieros\nZakres:\nZakres (1,00 – 15,00) mg\n(z obliczen) ISO 4387:2019","categories":["other"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6aa34bf6576d0c1fdcb81cb8","lab_id":"69ad52a3de79e566650fb205","country":"PL","accr_number":"AB 406","accr_body":"PCA","test_object":"Papierosy","methodology":"Zdolność zapłonu papierosów","parameters":[{"name":"Zakres","range":"(0 – 100) %FLB"}],"technique":"Metoda spalania w komorze testowej","techniques":["Metoda spalania w komorze testowej"],"computed":[],"activity":"Zdolność zapłonu papierosów\nZakres (0 – 100) %FLB\nMetoda spalania w komorze testowej","reference":"ASTM E 2187-2024 | ISO 12863:2022-04","norm_bases":["ASTM E 2187-2024","ISO 12863:2022-04"],"lab_section":"Laboratorium Chemiczne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Papierosy Zdolność zapłonu papierosów\nZakres (0 – 100) %FLB\nMetoda spalania w komorze testowej ASTM E 2187-2024 | ISO 12863:2022-04 Papierosy Zdolnosc zaplonu papierosow\nZakres (0 – 100) %FLB\nMetoda spalania w komorze testowej ASTM E 2187-2024 | ISO 12863:2022-04","categories":["other"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code"}],"has_pdf":true}