{"lab":{"_id":"69ad52a3de79e566650fb1fb","accr_number":"AB 394","country":"PL","accr_body":"PCA","address":"ul. Sowińskiego 5, 44-100 Gliwice, ODDZIAŁ W SKAWINIE, LABORATORIUM METALOZNAWSTWA I ANALIZ CHEMICZNYCH, ul. Piłsudskiego 19","categories":["materials"],"city":"Gliwice","imported_at":"2026-03-08T10:42:43.265Z","methods_count":15,"name":"SIEĆ BADAWCZA ŁUKASIEWICZ - INSTYTUT METALI NIEŻELAZNYCH","parse_status":"parsed","parse_version":3,"pdf_files":["AB_394.pdf"],"scope_summary":"","search_text":"sieć badawcza łukasiewicz - instytut metali nieżelaznych ul. sowińskiego 5, 44-100 gliwice, oddział w skawinie, laboratorium metaloznawstwa i analiz chemicznych, ul. piłsudskiego 19 materials other environment pharma electronics","status":"active","updated_at":"2026-03-08T14:51:13.593Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-17T20:06:35.790Z","location":{"type":"Point","coordinates":[18.6714,50.2945]},"email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20394,podmiot.html","fields_of_testing":[{"codes":"C/8","pl":"Badania chemiczne metali","en":"Chemical tests of metals"},{"codes":"J/8, J/12","pl":"Badania mechaniczne, badania metalograficzne wyrobów i materiałów konstrukcyjnych w tym metali, kompozytów i ceramiki","en":"Mechanical and metallographic tests of structural products and materials including metals, composites, ceramics"},{"codes":"N/8","pl":"Badania właściwości fizycznych wyrobów i materiałów konstrukcyjnych w tym metali i kompozytów","en":"Physical properties tests of structural products and materials including metals, composites"},{"codes":"L/8","pl":"Badania nieniszczące powłok na metalach i stopach metali","en":"Non-destructive tests of coatings on metals and metal alloys"}],"issue":{"no":"27","date":"23.07.2026"},"parse_date":"2026-08-17T20:06:35.790Z","parse_source":"agent-claude-code","map_coord":[50.295789,18.633954],"map_geo":"nominatim-street","lab_locations":[{"name":"ODDZIAŁ W SKAWINIE","address":"ul. Piłsudskiego 19","city":"Skawina","postal":"32-050"},{"name":"LABORATORIUM METALOZNAWSTWA I ANALIZ CHEMICZNYCH","address":"ul. Piłsudskiego 19","city":"Skawina","postal":"32-050"},{"name":"Sekcja Analiz Chemicznych","address":"ul. Piłsudskiego 19, 32-050 Skawina","city":"Skawina","postal":"32-050"},{"name":"Sekcja Metaloznawstwa","address":"ul. Piłsudskiego 19, 32-050 Skawina","city":"Skawina","postal":"32-050"}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/46be5c4f91a1e2e6b609fb1131f1dc5d/AB%20394.pdf","has_en":true,"category_counts":{"materials":14,"other":1},"category_scores":{"materials":13.07,"other":0.07},"has_zh":true},"methods":[{"_id":"6a8369cbaf14b9c0e7b1dc04","lab_id":"69ad52a3de79e566650fb1fb","country":"PL","accr_number":"AB 394","accr_body":"PCA","test_object":"Aluminium i stopy aluminium","methodology":"Zawartość pierwiastków","parameters":[{"name":"B","range":"(0,0001 - 0,025) % wag."},{"name":"Be","range":"(0,0001 - 0,05) % wag."},{"name":"Bi","range":"(0,0015 - 0,75) % wag."},{"name":"Ca","range":"(0,0003 - 0,025) % wag."},{"name":"Cr","range":"(0,005 - 0,5) % wag."},{"name":"Cu","range":"(0,0015 - 8,0) % wag."},{"name":"Fe","range":"(0,0025 - 2,0) % wag."},{"name":"Li","range":"(0,0001 - 0,03) % wag."},{"name":"Mg","range":"(0,0001 - 6,0) % wag."},{"name":"Mn","range":"(0,0005 - 2,0) % wag."},{"name":"Na","range":"(0,0001 - 0,015) % wag."},{"name":"Ni","range":"(0,001 - 2,0) % wag."},{"name":"P","range":"(0,001 - 0,02) % wag."},{"name":"Pb","range":"(0,001 - 0,75) % wag."},{"name":"Sb","range":"(0,001 - 0,066) % wag."},{"name":"Si","range":"(0,0005 - 20,0) % wag."},{"name":"Sn","range":"(0,0025 - 0,75) % wag."},{"name":"Sr","range":"(0,0001 - 0,015) % wag."},{"name":"Ti","range":"(0,0002 - 0,5) % wag."},{"name":"V","range":"(0,001 - 0,15) % wag."},{"name":"Zn","range":"(0,001 - 10,0) % wag."},{"name":"Zr","range":"(0,0002 - 0,5) % wag."}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem iskrowym","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem iskrowym"],"computed":[],"activity":"Zawartość pierwiastków\nZakres:\nB (0,0001 - 0,025) % wag.\nBe (0,0001 - 0,05) % wag.\nBi (0,0015 - 0,75) % wag.\nCa (0,0003 - 0,025) % wag.\nCr (0,005 - 0,5) % wag.\nCu (0,0015 - 8,0) % wag.\nFe (0,0025 - 2,0) % wag.\nLi (0,0001 - 0,03) % wag.\nMg (0,0001 - 6,0) % wag.\nMn (0,0005 - 2,0) % wag.\nNa (0,0001 - 0,015) % wag.\nNi (0,001 - 2,0) % wag.\nP (0,001 - 0,02) % wag.\nPb (0,001 - 0,75) % wag.\nSb (0,001 - 0,066) % wag.\nSi (0,0005 - 20,0) % wag.\nSn (0,0025 - 0,75) % wag.\nSr (0,0001 - 0,015) % wag.\nTi (0,0002 - 0,5) % wag.\nV (0,001 - 0,15) % wag.\nZn (0,001 - 10,0) % wag.\nZr (0,0002 - 0,5) % wag.\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem iskrowym","reference":"PB-7 Wydanie VII z 29.12.2025 r.","norm_bases":["PB-7 Wydanie VII z 29.12.2025 r."],"lab_section":"Sekcja Analiz Chemicznych","lab_address":null,"regulatory_area":"Badania, na podstawie wyników których laboratorium formułuje opinie i interpretacje oznaczone zostały symbolem *","flexible":false,"search_text":"Aluminium i stopy aluminium Zawartość pierwiastków\nZakres:\nB (0,0001 - 0,025) % wag.\nBe (0,0001 - 0,05) % wag.\nBi (0,0015 - 0,75) % wag.\nCa (0,0003 - 0,025) % wag.\nCr (0,005 - 0,5) % wag.\nCu (0,0015 - 8,0) % wag.\nFe (0,0025 - 2,0) % wag.\nLi (0,0001 - 0,03) % wag.\nMg (0,0001 - 6,0) % wag.\nMn (0,0005 - 2,0) % wag.\nNa (0,0001 - 0,015) % wag.\nNi (0,001 - 2,0) % wag.\nP (0,001 - 0,02) % wag.\nPb (0,001 - 0,75) % wag.\nSb (0,001 - 0,066) % wag.\nSi (0,0005 - 20,0) % wag.\nSn (0,0025 - 0,75) % wag.\nSr (0,0001 - 0,015) % wag.\nTi (0,0002 - 0,5) % wag.\nV (0,001 - 0,15) % wag.\nZn (0,001 - 10,0) % wag.\nZr (0,0002 - 0,5) % wag.\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem iskrowym PB-7 Wydanie VII z 29.12.2025 r. Aluminium i stopy aluminium Zawartosc pierwiastkow\nZakres:\nB (0,0001 - 0,025) % wag.\nBe (0,0001 - 0,05) % wag.\nBi (0,0015 - 0,75) % wag.\nCa (0,0003 - 0,025) % wag.\nCr (0,005 - 0,5) % wag.\nCu (0,0015 - 8,0) % wag.\nFe (0,0025 - 2,0) % wag.\nLi (0,0001 - 0,03) % wag.\nMg (0,0001 - 6,0) % wag.\nMn (0,0005 - 2,0) % wag.\nNa (0,0001 - 0,015) % wag.\nNi (0,001 - 2,0) % wag.\nP (0,001 - 0,02) % wag.\nPb (0,001 - 0,75) % wag.\nSb (0,001 - 0,066) % wag.\nSi (0,0005 - 20,0) % wag.\nSn (0,0025 - 0,75) % wag.\nSr (0,0001 - 0,015) % wag.\nTi (0,0002 - 0,5) % wag.\nV (0,001 - 0,15) % wag.\nZn (0,001 - 10,0) % wag.\nZr (0,0002 - 0,5) % wag.\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem iskrowym PB-7 Wydanie VII z 29.12.2025 r.","categories":["materials"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element content","parameters_en":[{"name":"B","range":"(0,0001 - 0,025) % wag."},{"name":"Be","range":"(0,0001 - 0,05) % wag."},{"name":"Bi","range":"(0,0015 - 0,75) % wag."},{"name":"Ca","range":"(0,0003 - 0,025) % wag."},{"name":"Cr","range":"(0,005 - 0,5) % wag."},{"name":"Cu","range":"(0,0015 - 8,0) % wag."},{"name":"Fe","range":"(0,0025 - 2,0) % wag."},{"name":"Li","range":"(0,0001 - 0,03) % wag."},{"name":"Mg","range":"(0,0001 - 6,0) % wag."},{"name":"Mn","range":"(0,0005 - 2,0) % wag."},{"name":"Na","range":"(0,0001 - 0,015) % wag."},{"name":"Ni","range":"(0,001 - 2,0) % wag."},{"name":"P","range":"(0,001 - 0,02) % wag."},{"name":"Pb","range":"(0,001 - 0,75) % wag."},{"name":"Sb","range":"(0,001 - 0,066) % wag."},{"name":"Si","range":"(0,0005 - 20,0) % wag."},{"name":"Sn","range":"(0,0025 - 0,75) % wag."},{"name":"Sr","range":"(0,0001 - 0,015) % wag."},{"name":"Ti","range":"(0,0002 - 0,5) % wag."},{"name":"V","range":"(0,001 - 0,15) % wag."},{"name":"Zn","range":"(0,001 - 10,0) % wag."},{"name":"Zr","range":"(0,0002 - 0,5) % wag."}],"regulatory_area_en":"Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol","search_en":"Aluminium and aluminium alloys Element content Spark excitation atomic emission spectrometry Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol B Be Bi Ca Cr Cu Fe Li Mg Mn Na Ni P Pb Sb Si Sn Sr Ti V Zn Zr PB-7 Wydanie VII z 29.12.2025 r.","technique_en":"Spark excitation atomic emission spectrometry","test_object_en":"Aluminium and aluminium alloys","methodology_zh":"元素含量","parameters_zh":[{"name":"B","range":"(0,0001 - 0,025) % wag."},{"name":"Be","range":"(0,0001 - 0,05) % wag."},{"name":"Bi","range":"(0,0015 - 0,75) % wag."},{"name":"Ca","range":"(0,0003 - 0,025) % wag."},{"name":"Cr","range":"(0,005 - 0,5) % wag."},{"name":"Cu","range":"(0,0015 - 8,0) % wag."},{"name":"Fe","range":"(0,0025 - 2,0) % wag."},{"name":"Li","range":"(0,0001 - 0,03) % wag."},{"name":"Mg","range":"(0,0001 - 6,0) % wag."},{"name":"Mn","range":"(0,0005 - 2,0) % wag."},{"name":"Na","range":"(0,0001 - 0,015) % wag."},{"name":"Ni","range":"(0,001 - 2,0) % wag."},{"name":"P","range":"(0,001 - 0,02) % wag."},{"name":"Pb","range":"(0,001 - 0,75) % wag."},{"name":"Sb","range":"(0,001 - 0,066) % wag."},{"name":"Si","range":"(0,0005 - 20,0) % wag."},{"name":"Sn","range":"(0,0025 - 0,75) % wag."},{"name":"Sr","range":"(0,0001 - 0,015) % wag."},{"name":"Ti","range":"(0,0002 - 0,5) % wag."},{"name":"V","range":"(0,001 - 0,15) % wag."},{"name":"Zn","range":"(0,001 - 10,0) % wag."},{"name":"Zr","range":"(0,0002 - 0,5) % wag."}],"search_zh":"铝与铝合金 元素含量 火花激发原子发射光谱法 实验室据以出具意见和解释的检测项目以 * 号标出 B Be Ca Cr Cu Fe Mg Mn Na Ni P Pb Sb Si Sn Sr Ti V Zn PB-7 Wydanie VII z 29.12.2025 r.","regulatory_area_zh":"实验室据以出具意见和解释的检测项目以 * 号标出","technique_zh":"火花激发原子发射光谱法","test_object_zh":"铝与铝合金"},{"_id":"6a8369cbaf14b9c0e7b1dc05","lab_id":"69ad52a3de79e566650fb1fb","country":"PL","accr_number":"AB 394","accr_body":"PCA","test_object":"Metale i stopy metali (Al, Fe, Ti)","methodology":"Zawartość wodoru","parameters":[{"name":"Zakres","range":"(0,001 - 400) ppm"}],"technique":"Metoda wysokotemperaturowej ekstrakcji z detekcją TC","techniques":["Metoda wysokotemperaturowej ekstrakcji z detekcją TC"],"computed":[],"activity":"Zawartość wodoru\nZakres (0,001 - 400) ppm\nMetoda wysokotemperaturowej ekstrakcji z detekcją TC","reference":"PB-5 Wydanie VI z 29.12.2025 r.","norm_bases":["PB-5 Wydanie VI z 29.12.2025 r."],"lab_section":"Sekcja Analiz Chemicznych","lab_address":null,"regulatory_area":"Badania, na podstawie wyników których laboratorium formułuje opinie i interpretacje oznaczone zostały symbolem *","flexible":false,"search_text":"Metale i stopy metali (Al, Fe, Ti) Zawartość wodoru\nZakres (0,001 - 400) ppm\nMetoda wysokotemperaturowej ekstrakcji z detekcją TC PB-5 Wydanie VI z 29.12.2025 r. Metale i stopy metali (Al, Fe, Ti) Zawartosc wodoru\nZakres (0,001 - 400) ppm\nMetoda wysokotemperaturowej ekstrakcji z detekcja TC PB-5 Wydanie VI z 29.12.2025 r.","categories":["materials"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrogen content","parameters_en":[{"name":"Range","range":"(0,001 - 400) ppm"}],"regulatory_area_en":"Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol","search_en":"Metals and metal alloys (Al, Fe, Ti) Hydrogen content High-temperature extraction with TC detection Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol Range PB-5 Wydanie VI z 29.12.2025 r.","technique_en":"High-temperature extraction with TC detection","test_object_en":"Metals and metal alloys (Al, Fe, Ti)","parameters_zh":[{"name":"范围","range":"(0,001 - 400) ppm"}],"search_zh":"氢含量 实验室据以出具意见和解释的检测项目以 * 号标出 范围 PB-5 Wydanie VI z 29.12.2025 r.","methodology_zh":"氢含量","regulatory_area_zh":"实验室据以出具意见和解释的检测项目以 * 号标出"},{"_id":"6a8369cbaf14b9c0e7b1dc06","lab_id":"69ad52a3de79e566650fb1fb","country":"PL","accr_number":"AB 394","accr_body":"PCA","test_object":"Powłoki na metalach i stopach metali","methodology":"Ścieralność aparatem Tabera","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ścieralność aparatem Tabera","reference":"ISO 10074:2021(E)","norm_bases":["ISO 10074:2021(E)"],"lab_section":"Sekcja Analiz Chemicznych","lab_address":null,"regulatory_area":"Badania, na podstawie wyników których laboratorium formułuje opinie i interpretacje oznaczone zostały symbolem *","flexible":false,"search_text":"Powłoki na metalach i stopach metali Ścieralność aparatem Tabera ISO 10074:2021(E) Powloki na metalach i stopach metali Scieralnosc aparatem Tabera ISO 10074:2021(E)","categories":["materials"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Abrasion resistance with the Taber abraser","regulatory_area_en":"Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol","search_en":"Coatings on metals and metal alloys Abrasion resistance with the Taber abraser Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol ISO 10074:2021(E)","test_object_en":"Coatings on metals and metal alloys","regulatory_area_zh":"实验室据以出具意见和解释的检测项目以 * 号标出","search_zh":"实验室据以出具意见和解释的检测项目以 * 号标出 ISO 10074:2021(E)"},{"_id":"6a8369cbaf14b9c0e7b1dc07","lab_id":"69ad52a3de79e566650fb1fb","country":"PL","accr_number":"AB 394","accr_body":"PCA","test_object":"Metale i ich stopy, powłoki na metalach i stopach metali","methodology":"Odporność na działanie obojętnej mgły solnej (NSS), Odporność na działanie kwaśnej mgły solnej (AASS), Odporność na działanie mgły solnej z kwasem octowym z dodatkiem chlorku miedzi (CASS)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na działanie obojętnej mgły solnej (NSS), Odporność na działanie kwaśnej mgły solnej (AASS), Odporność na działanie mgły solnej z kwasem octowym z dodatkiem chlorku miedzi (CASS)","reference":"PN-EN ISO 9227:2023-02","norm_bases":["PN-EN ISO 9227:2023-02"],"lab_section":"Sekcja Analiz Chemicznych","lab_address":null,"regulatory_area":"Badania, na podstawie wyników których laboratorium formułuje opinie i interpretacje oznaczone zostały symbolem *","flexible":false,"search_text":"Metale i ich stopy, powłoki na metalach i stopach metali Odporność na działanie obojętnej mgły solnej (NSS), Odporność na działanie kwaśnej mgły solnej (AASS), Odporność na działanie mgły solnej z kwasem octowym z dodatkiem chlorku miedzi (CASS) PN-EN ISO 9227:2023-02 Metale i ich stopy, powloki na metalach i stopach metali Odpornosc na dzialanie obojetnej mgly solnej (NSS), Odpornosc na dzialanie kwasnej mgly solnej (AASS), Odpornosc na dzialanie mgly solnej z kwasem octowym z dodatkiem chlorku miedzi (CASS) PN-EN ISO 9227:2023-02","categories":["materials"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Resistance to neutral salt spray (NSS), Resistance to acetic acid salt spray (AASS), Resistance to copper-accelerated acetic acid salt spray (CASS)","regulatory_area_en":"Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol","search_en":"Metals and their alloys, coatings on metals and metal alloys Resistance to neutral salt spray (NSS), Resistance to acetic acid salt spray (AASS), Resistance to copper-accelerated acetic acid salt spray (CASS) Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol PN-EN ISO 9227:2023-02","test_object_en":"Metals and their alloys, coatings on metals and metal alloys","regulatory_area_zh":"实验室据以出具意见和解释的检测项目以 * 号标出","search_zh":"实验室据以出具意见和解释的检测项目以 * 号标出 PN-EN ISO 9227:2023-02"},{"_id":"6a8369cbaf14b9c0e7b1dc08","lab_id":"69ad52a3de79e566650fb1fb","country":"PL","accr_number":"AB 394","accr_body":"PCA","test_object":"Powłoki na metalach i stopach metali","methodology":"Grubość powłok nieprzewodzących na podłożu niemagnetycznym przewodzącym elektryczność","parameters":[{"name":"Zakres","range":"(0 - 800) μm"}],"technique":"Metoda prądów wirowych","techniques":["Metoda prądów wirowych"],"computed":[],"activity":"Grubość powłok nieprzewodzących na podłożu niemagnetycznym przewodzącym elektryczność\nZakres (0 - 800) μm\nMetoda prądów wirowych","reference":"PN-EN ISO 2360:2017-10","norm_bases":["PN-EN ISO 2360:2017-10"],"lab_section":"Sekcja Analiz Chemicznych","lab_address":null,"regulatory_area":"Badania, na podstawie wyników których laboratorium formułuje opinie i interpretacje oznaczone zostały symbolem *","flexible":false,"search_text":"Powłoki na metalach i stopach metali Grubość powłok nieprzewodzących na podłożu niemagnetycznym przewodzącym elektryczność\nZakres (0 - 800) μm\nMetoda prądów wirowych PN-EN ISO 2360:2017-10 Powloki na metalach i stopach metali Grubosc powlok nieprzewodzacych na podlozu niemagnetycznym przewodzacym elektrycznosc\nZakres (0 - 800) μm\nMetoda pradow wirowych PN-EN ISO 2360:2017-10","categories":["materials"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0 - 800) μm"}],"regulatory_area_en":"Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol","search_en":"Coatings on metals and metal alloys Eddy current method Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol Range PN-EN ISO 2360:2017-10","technique_en":"Eddy current method","test_object_en":"Coatings on metals and metal alloys","parameters_zh":[{"name":"范围","range":"(0 - 800) μm"}],"search_zh":"涡流法 实验室据以出具意见和解释的检测项目以 * 号标出 范围 PN-EN ISO 2360:2017-10","regulatory_area_zh":"实验室据以出具意见和解释的检测项目以 * 号标出","technique_zh":"涡流法"},{"_id":"6a8369cbaf14b9c0e7b1dc09","lab_id":"69ad52a3de79e566650fb1fb","country":"PL","accr_number":"AB 394","accr_body":"PCA","test_object":"Metale, stopy metali i ceramika","methodology":"Twardość HV","parameters":[{"name":"Zakres","range":"HV0,2; HV0,3; HV0,5; HV1; HV5; HV10; HV30; HV50; HV100."}],"technique":"Metoda Vickersa","techniques":["Metoda Vickersa"],"computed":[],"activity":"Twardość HV\nZakres HV0,2; HV0,3; HV0,5; HV1; HV5; HV10; HV30; HV50; HV100.\nMetoda Vickersa","reference":"PN-EN ISO 6507-1:2024-04","norm_bases":["PN-EN ISO 6507-1:2024-04"],"lab_section":"Sekcja Metaloznawstwa","lab_address":null,"regulatory_area":"Badania, na podstawie wyników których laboratorium formułuje opinie i interpretacje oznaczone zostały symbolem *","flexible":false,"search_text":"Metale, stopy metali i ceramika Twardość HV\nZakres HV0,2; HV0,3; HV0,5; HV1; HV5; HV10; HV30; HV50; HV100.\nMetoda Vickersa PN-EN ISO 6507-1:2024-04 Metale, stopy metali i ceramika Twardosc HV\nZakres HV0,2; HV0,3; HV0,5; HV1; HV5; HV10; HV30; HV50; HV100.\nMetoda Vickersa PN-EN ISO 6507-1:2024-04","categories":["materials"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"HV hardness","parameters_en":[{"name":"Range","range":"HV0,2; HV0,3; HV0,5; HV1; HV5; HV10; HV30; HV50; HV100."}],"regulatory_area_en":"Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol","search_en":"Metals, metal alloys and ceramics HV hardness Vickers method Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol Range PN-EN ISO 6507-1:2024-04","technique_en":"Vickers method","test_object_en":"Metals, metal alloys and ceramics","parameters_zh":[{"name":"范围","range":"HV0,2; HV0,3; HV0,5; HV1; HV5; HV10; HV30; HV50; HV100."}],"search_zh":"维氏硬度 HV 维氏法 实验室据以出具意见和解释的检测项目以 * 号标出 范围 PN-EN ISO 6507-1:2024-04","regulatory_area_zh":"实验室据以出具意见和解释的检测项目以 * 号标出","methodology_zh":"维氏硬度 HV","technique_zh":"维氏法"},{"_id":"6a8369cbaf14b9c0e7b1dc0a","lab_id":"69ad52a3de79e566650fb1fb","country":"PL","accr_number":"AB 394","accr_body":"PCA","test_object":"Metale i stopy metali","methodology":"Twardość HBW","parameters":[{"name":"Zakres","range":"średnica kulki 2.5 i 5 mm"}],"technique":"Metoda Brinella","techniques":["Metoda Brinella"],"computed":[],"activity":"Twardość HBW\nZakres średnica kulki 2.5 i 5 mm\nMetoda Brinella","reference":"PN-EN ISO 6506-1:2014-12","norm_bases":["PN-EN ISO 6506-1:2014-12"],"lab_section":"Sekcja Metaloznawstwa","lab_address":null,"regulatory_area":"Badania, na podstawie wyników których laboratorium formułuje opinie i interpretacje oznaczone zostały symbolem *","flexible":false,"search_text":"Metale i stopy metali Twardość HBW\nZakres średnica kulki 2.5 i 5 mm\nMetoda Brinella PN-EN ISO 6506-1:2014-12 Metale i stopy metali Twardosc HBW\nZakres srednica kulki 2.5 i 5 mm\nMetoda Brinella PN-EN ISO 6506-1:2014-12","categories":["materials"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"HBW hardness","parameters_en":[{"name":"Range","range":"średnica kulki 2.5 i 5 mm"}],"regulatory_area_en":"Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol","search_en":"Metals and metal alloys HBW hardness Brinell method Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol Range PN-EN ISO 6506-1:2014-12","technique_en":"Brinell method","test_object_en":"Metals and metal alloys","parameters_zh":[{"name":"范围","range":"średnica kulki 2.5 i 5 mm"}],"search_zh":"金属与合金 布氏硬度 HBW 布氏法 实验室据以出具意见和解释的检测项目以 * 号标出 范围 PN-EN ISO 6506-1:2014-12","regulatory_area_zh":"实验室据以出具意见和解释的检测项目以 * 号标出","test_object_zh":"金属与合金","methodology_zh":"布氏硬度 HBW","technique_zh":"布氏法"},{"_id":"6a8369cbaf14b9c0e7b1dc0b","lab_id":"69ad52a3de79e566650fb1fb","country":"PL","accr_number":"AB 394","accr_body":"PCA","test_object":"Metale i stopy metali","methodology":"Własności mechaniczne","parameters":[{"name":"umowna granica plastyczności Rp"},{"name":"wyraźna granica plastyczności Re"},{"name":"wytrzymałość na rozciąganie Rm"},{"name":"wydłużenie A"},{"name":"przewężenie Z"},{"name":"Zakres: siła F","range":"do 100kN"}],"technique":"Próba rozciągania w temperaturze pokojowej","techniques":["Próba rozciągania w temperaturze pokojowej"],"computed":[],"activity":"Własności mechaniczne\nZakres:\numowna granica plastyczności Rp\nwyraźna granica plastyczności Re\nwytrzymałość na rozciąganie Rm\nwydłużenie A\nprzewężenie Z\nZakres: siła F do 100kN\nPróba rozciągania w temperaturze pokojowej","reference":"PN-EN ISO 6892-1:2020-05 Metoda A Metoda B","norm_bases":["PN-EN ISO 6892-1:2020-05 Metoda A Metoda B"],"lab_section":"Sekcja Metaloznawstwa","lab_address":null,"regulatory_area":"Badania, na podstawie wyników których laboratorium formułuje opinie i interpretacje oznaczone zostały symbolem *","flexible":false,"search_text":"Metale i stopy metali Własności mechaniczne\nZakres:\numowna granica plastyczności Rp\nwyraźna granica plastyczności Re\nwytrzymałość na rozciąganie Rm\nwydłużenie A\nprzewężenie Z\nZakres: siła F do 100kN\nPróba rozciągania w temperaturze pokojowej PN-EN ISO 6892-1:2020-05 Metoda A Metoda B Metale i stopy metali Wlasnosci mechaniczne\nZakres:\numowna granica plastycznosci Rp\nwyrazna granica plastycznosci Re\nwytrzymalosc na rozciaganie Rm\nwydluzenie A\nprzewezenie Z\nZakres: sila F do 100kN\nProba rozciagania w temperaturze pokojowej PN-EN ISO 6892-1:2020-05 Metoda A Metoda B","categories":["materials"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mechanical properties","parameters_en":[{"name":"proof strength, plastic extension Rp"},{"name":"distinct yield strength Re"},{"name":"tensile strength Rm"},{"name":"elongation A"},{"name":"reduction of area Z"},{"name":"Range: force F","range":"do 100kN"}],"regulatory_area_en":"Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol","search_en":"Metals and metal alloys Mechanical properties Tensile test at room temperature Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol proof strength, plastic extension Rp distinct yield strength Re tensile strength Rm elongation A reduction of area Z Range: force F PN-EN ISO 6892-1:2020-05 Metoda A Metoda B","technique_en":"Tensile test at room temperature","test_object_en":"Metals and metal alloys","regulatory_area_zh":"实验室据以出具意见和解释的检测项目以 * 号标出","search_zh":"金属与合金 力学性能 室温拉伸试验 实验室据以出具意见和解释的检测项目以 * 号标出 规定塑性延伸强度 Rp 明显屈服强度 Re 抗拉强度 Rm 伸长率 A 断面收缩率 Z 范围：力 F PN-EN ISO 6892-1:2020-05 Metoda A Metoda B","parameters_zh":[{"name":"规定塑性延伸强度 Rp"},{"name":"明显屈服强度 Re"},{"name":"抗拉强度 Rm"},{"name":"伸长率 A"},{"name":"断面收缩率 Z"},{"name":"范围：力 F","range":"do 100kN"}],"technique_zh":"室温拉伸试验","test_object_zh":"金属与合金","methodology_zh":"力学性能"},{"_id":"6a8369cbaf14b9c0e7b1dc0c","lab_id":"69ad52a3de79e566650fb1fb","country":"PL","accr_number":"AB 394","accr_body":"PCA","test_object":"Metale i stopy metali","methodology":"Makrostruktura","parameters":[],"technique":"Obserwacje wizualne","techniques":["Obserwacje wizualne"],"computed":[],"activity":"Makrostruktura\nObserwacje wizualne","reference":"PB-K Wydanie VII z 29.12.2025 r.","norm_bases":["PB-K Wydanie VII z 29.12.2025 r."],"lab_section":"Sekcja Metaloznawstwa","lab_address":null,"regulatory_area":"Badania, na podstawie wyników których laboratorium formułuje opinie i interpretacje oznaczone zostały symbolem *","flexible":false,"search_text":"Metale i stopy metali Makrostruktura\nObserwacje wizualne PB-K Wydanie VII z 29.12.2025 r. Metale i stopy metali Makrostruktura\nObserwacje wizualne PB-K Wydanie VII z 29.12.2025 r.","categories":["materials"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Macrostructure","regulatory_area_en":"Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol","search_en":"Metals and metal alloys Macrostructure Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol PB-K Wydanie VII z 29.12.2025 r.","test_object_en":"Metals and metal alloys","regulatory_area_zh":"实验室据以出具意见和解释的检测项目以 * 号标出","search_zh":"金属与合金 宏观组织 实验室据以出具意见和解释的检测项目以 * 号标出 PB-K Wydanie VII z 29.12.2025 r.","test_object_zh":"金属与合金","methodology_zh":"宏观组织"},{"_id":"6a8369cbaf14b9c0e7b1dc0d","lab_id":"69ad52a3de79e566650fb1fb","country":"PL","accr_number":"AB 394","accr_body":"PCA","test_object":"Metale i stopy metali","methodology":"Makrostruktura i mikrostruktura","parameters":[],"technique":"Ilościowa analiza elementów struktury","techniques":["Ilościowa analiza elementów struktury"],"computed":[],"activity":"Makrostruktura i mikrostruktura\nIlościowa analiza elementów struktury","reference":"PB-A Wydanie V z 29.12.2025 r.","norm_bases":["PB-A Wydanie V z 29.12.2025 r."],"lab_section":"Sekcja Metaloznawstwa","lab_address":null,"regulatory_area":"Badania, na podstawie wyników których laboratorium formułuje opinie i interpretacje oznaczone zostały symbolem *","flexible":false,"search_text":"Metale i stopy metali Makrostruktura i mikrostruktura\nIlościowa analiza elementów struktury PB-A Wydanie V z 29.12.2025 r. Metale i stopy metali Makrostruktura i mikrostruktura\nIlosciowa analiza elementow struktury PB-A Wydanie V z 29.12.2025 r.","categories":["materials"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","regulatory_area_en":"Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol","search_en":"Metals and metal alloys Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol PB-A Wydanie V z 29.12.2025 r.","test_object_en":"Metals and metal alloys","regulatory_area_zh":"实验室据以出具意见和解释的检测项目以 * 号标出","search_zh":"金属与合金 实验室据以出具意见和解释的检测项目以 * 号标出 PB-A Wydanie V z 29.12.2025 r.","test_object_zh":"金属与合金"},{"_id":"6a8369cbaf14b9c0e7b1dc0e","lab_id":"69ad52a3de79e566650fb1fb","country":"PL","accr_number":"AB 394","accr_body":"PCA","test_object":"Metale i stopy metali","methodology":"Mikrostruktura","parameters":[],"technique":"Metoda mikroskopii świetlnej","techniques":["Metoda mikroskopii świetlnej"],"computed":[],"activity":"Mikrostruktura\nMetoda mikroskopii świetlnej","reference":"PB-O Wydanie VIII z 29.12.2025 r.","norm_bases":["PB-O Wydanie VIII z 29.12.2025 r."],"lab_section":"Sekcja Metaloznawstwa","lab_address":null,"regulatory_area":"Badania, na podstawie wyników których laboratorium formułuje opinie i interpretacje oznaczone zostały symbolem *","flexible":false,"search_text":"Metale i stopy metali Mikrostruktura\nMetoda mikroskopii świetlnej PB-O Wydanie VIII z 29.12.2025 r. Metale i stopy metali Mikrostruktura\nMetoda mikroskopii swietlnej PB-O Wydanie VIII z 29.12.2025 r.","categories":["materials"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Microstructure","regulatory_area_en":"Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol","search_en":"Metals and metal alloys Microstructure Light microscopy method Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol PB-O Wydanie VIII z 29.12.2025 r.","technique_en":"Light microscopy method","test_object_en":"Metals and metal alloys","regulatory_area_zh":"实验室据以出具意见和解释的检测项目以 * 号标出","search_zh":"金属与合金 显微组织 实验室据以出具意见和解释的检测项目以 * 号标出 PB-O Wydanie VIII z 29.12.2025 r.","test_object_zh":"金属与合金","methodology_zh":"显微组织"},{"_id":"6a8369cbaf14b9c0e7b1dc0f","lab_id":"69ad52a3de79e566650fb1fb","country":"PL","accr_number":"AB 394","accr_body":"PCA","test_object":"Metale, stopy metali, Metale nieżelazne","methodology":"Mikrostruktura","parameters":[],"technique":"Metoda transmisyjnej mikroskopii elektronowej","techniques":["Metoda transmisyjnej mikroskopii elektronowej"],"computed":[],"activity":"Mikrostruktura\nMetoda transmisyjnej mikroskopii elektronowej","reference":"PB-E Wydanie VII z 29.12.2025 r.","norm_bases":["PB-E Wydanie VII z 29.12.2025 r."],"lab_section":"Sekcja Metaloznawstwa","lab_address":null,"regulatory_area":"Badania, na podstawie wyników których laboratorium formułuje opinie i interpretacje oznaczone zostały symbolem *","flexible":false,"search_text":"Metale, stopy metali, Metale nieżelazne Mikrostruktura\nMetoda transmisyjnej mikroskopii elektronowej PB-E Wydanie VII z 29.12.2025 r. Metale, stopy metali, Metale niezelazne Mikrostruktura\nMetoda transmisyjnej mikroskopii elektronowej PB-E Wydanie VII z 29.12.2025 r.","categories":["materials"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Microstructure","regulatory_area_en":"Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol","search_en":"Metals, metal alloys, Non-ferrous metals Microstructure Transmission electron microscopy method Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol PB-E Wydanie VII z 29.12.2025 r.","technique_en":"Transmission electron microscopy method","test_object_en":"Metals, metal alloys, Non-ferrous metals","regulatory_area_zh":"实验室据以出具意见和解释的检测项目以 * 号标出","search_zh":"显微组织 实验室据以出具意见和解释的检测项目以 * 号标出 PB-E Wydanie VII z 29.12.2025 r.","methodology_zh":"显微组织"},{"_id":"6a8369cbaf14b9c0e7b1dc10","lab_id":"69ad52a3de79e566650fb1fb","country":"PL","accr_number":"AB 394","accr_body":"PCA","test_object":"Metale, stopy metali, Materiały ceramiczne","methodology":"Fraktografia, Jakościowy skład chemiczny w mikroobszarach","parameters":[],"technique":"Metoda skaningowej mikroskopii elektronowej","techniques":["Metoda skaningowej mikroskopii elektronowej"],"computed":[],"activity":"Fraktografia, Jakościowy skład chemiczny w mikroobszarach\nMetoda skaningowej mikroskopii elektronowej","reference":"PB-SK Wydanie VI z 29.12.2025 r.","norm_bases":["PB-SK Wydanie VI z 29.12.2025 r."],"lab_section":"Sekcja Metaloznawstwa","lab_address":null,"regulatory_area":"Badania, na podstawie wyników których laboratorium formułuje opinie i interpretacje oznaczone zostały symbolem *","flexible":false,"search_text":"Metale, stopy metali, Materiały ceramiczne Fraktografia, Jakościowy skład chemiczny w mikroobszarach\nMetoda skaningowej mikroskopii elektronowej PB-SK Wydanie VI z 29.12.2025 r. Metale, stopy metali, Materialy ceramiczne Fraktografia, Jakosciowy sklad chemiczny w mikroobszarach\nMetoda skaningowej mikroskopii elektronowej PB-SK Wydanie VI z 29.12.2025 r.","categories":["materials"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fractography, Qualitative chemical composition in microareas","regulatory_area_en":"Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol","search_en":"Metals, metal alloys, Ceramic materials Fractography, Qualitative chemical composition in microareas Scanning electron microscopy method Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol PB-SK Wydanie VI z 29.12.2025 r.","technique_en":"Scanning electron microscopy method","test_object_en":"Metals, metal alloys, Ceramic materials","regulatory_area_zh":"实验室据以出具意见和解释的检测项目以 * 号标出","search_zh":"扫描电子显微镜法 实验室据以出具意见和解释的检测项目以 * 号标出 PB-SK Wydanie VI z 29.12.2025 r.","technique_zh":"扫描电子显微镜法"},{"_id":"6a8369cbaf14b9c0e7b1dc11","lab_id":"69ad52a3de79e566650fb1fb","country":"PL","accr_number":"AB 394","accr_body":"PCA","test_object":"Materiały krystaliczne","methodology":"Naprężenia własne","parameters":[],"technique":"Metoda dyfrakcji rentgenowskiej","techniques":["Metoda dyfrakcji rentgenowskiej"],"computed":[],"activity":"Naprężenia własne\nMetoda dyfrakcji rentgenowskiej","reference":"PB-N Wydanie VI z 29.12.2025 r.*","norm_bases":["PB-N Wydanie VI z 29.12.2025 r.*"],"lab_section":"Sekcja Metaloznawstwa","lab_address":null,"regulatory_area":"Badania, na podstawie wyników których laboratorium formułuje opinie i interpretacje oznaczone zostały symbolem *","flexible":false,"search_text":"Materiały krystaliczne Naprężenia własne\nMetoda dyfrakcji rentgenowskiej PB-N Wydanie VI z 29.12.2025 r.* Materialy krystaliczne Naprezenia wlasne\nMetoda dyfrakcji rentgenowskiej PB-N Wydanie VI z 29.12.2025 r.*","categories":["materials"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Residual stresses","regulatory_area_en":"Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol","search_en":"Crystalline materials Residual stresses X-ray diffraction method Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol PB-N Wydanie VI z 29.12.2025 r.*","technique_en":"X-ray diffraction method","test_object_en":"Crystalline materials","regulatory_area_zh":"实验室据以出具意见和解释的检测项目以 * 号标出","search_zh":"X射线衍射法 实验室据以出具意见和解释的检测项目以 * 号标出 PB-N Wydanie VI z 29.12.2025 r.*","technique_zh":"X射线衍射法"},{"_id":"6a8369cbaf14b9c0e7b1dc12","lab_id":"69ad52a3de79e566650fb1fb","country":"PL","accr_number":"AB 394","accr_body":"PCA","test_object":"Stale","methodology":"Zawartość austenitu szczątkowego","parameters":[],"technique":"Metoda dyfrakcji rentgenowskiej","techniques":["Metoda dyfrakcji rentgenowskiej"],"computed":[],"activity":"Zawartość austenitu szczątkowego\nMetoda dyfrakcji rentgenowskiej","reference":"PB-As Wydanie VI z 29.12.2025 r.","norm_bases":["PB-As Wydanie VI z 29.12.2025 r."],"lab_section":"Sekcja Metaloznawstwa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Stale Zawartość austenitu szczątkowego\nMetoda dyfrakcji rentgenowskiej PB-As Wydanie VI z 29.12.2025 r. Stale Zawartosc austenitu szczatkowego\nMetoda dyfrakcji rentgenowskiej PB-As Wydanie VI z 29.12.2025 r.","categories":["other"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Retained austenite content","search_en":"Steels Retained austenite content X-ray diffraction method PB-As Wydanie VI z 29.12.2025 r.","technique_en":"X-ray diffraction method","test_object_en":"Steels","search_zh":"钢 X射线衍射法 PB-As Wydanie VI z 29.12.2025 r.","technique_zh":"X射线衍射法","test_object_zh":"钢"}],"has_pdf":true}