{"lab":{"_id":"69ad52a3de79e566650fb1f1","accr_number":"AB 386","country":"PL","accr_body":"PCA","address":"ul. Rybaki 31/35, 87-100 Toruń","categories":["water","microbiology"],"city":"Toruń","imported_at":"2026-03-08T10:42:43.265Z","methods_count":49,"name":"TORUŃSKIE WODOCIĄGI Sp. z o.o.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_386.pdf"],"scope_summary":"","search_text":"toruńskie wodociągi sp. z o.o. ul. rybaki 31/35, 87-100 toruń water other pharma electronics materials food microbiology","status":"active","updated_at":"2026-03-08T14:51:13.090Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:13.090Z","location":{"type":"Point","coordinates":[18.5984,53.0138]},"email_confidence":"high","email_mx":true,"email_source":"http://torunskiewodociagi.bip.gov.pl/kontakt/kontakt.html","fields_of_testing":[{"codes":"C/28/P; C/29/P; C/30/P","pl":"Badania chemiczne i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków","en":"Chemical tests and sampling of water, drinking water, sewage"},{"codes":"K/28/P; K/29/P","pl":"Badania mikrobiologiczne i pobieranie próbek wody, wody do spożycia przez ludzi","en":"Microbiological tests and sampling of water, drinking water"},{"codes":"N/28/P; N/29/P; N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków","en":"Physical properties and sampling of water, drinking water, sewage"},{"codes":"Q/28/P; Q/29/P","pl":"Badania sensoryczne i pobieranie próbek wody, wody do spożycia przez ludzi","en":"Sensory tests and sampling of water, drinking water"}],"issue":{"no":"23","date":"23.01.2026"},"parse_date":"2026-07-20T07:09:35.709Z","parse_source":"script-pdfplumber","map_coord":[53.008069,18.587719],"map_geo":"nominatim-street","has_en":true,"category_counts":{"water":49,"microbiology":5,"materials":1,"petro":1},"category_scores":{"water":42.88,"microbiology":0.45,"materials":0.02,"petro":0.02},"has_zh":true},"methods":[{"_id":"6a5dc9aff1c10c8ce825b3b7","lab_id":"69ad52a3de79e566650fb1f1","country":"PL","accr_number":"AB 386","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Pobieranie próbek do badań chemicznych i fizycznych (w tym sensorycznych)","methodology_en":"Sampling for chemical and physical testing (including sensory testing)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych (w tym sensorycznych)","reference":"PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.2, 7.3, 7.5, 7.6 i 8.2 | PN-ISO 5667-5:2017-10","norm_bases":["PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.2, 7.3, 7.5, 7.6 i 8.2","PN-ISO 5667-5:2017-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych (w tym sensorycznych) PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.2, 7.3, 7.5, 7.6 i 8.2 | PN-ISO 5667-5:2017-10 Woda Pobieranie probek do badan chemicznych i fizycznych (w tym sensorycznych) PN-EN ISO 5667-6:2016-12 z wylaczeniem pkt. 7.2, 7.3, 7.5, 7.6 i 8.2 | PN-ISO 5667-5:2017-10","categories":["water"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Sampling for chemical and physical testing (including sensory testing) PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.2, 7.3, 7.5, 7.6 i 8.2 | PN-ISO 5667-5:2017-10","search_zh":"水 化学和物理检测采样（含感官检测） PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.2, 7.3, 7.5, 7.6 i 8.2 | PN-ISO 5667-5:2017-10","test_object_zh":"水","methodology_zh":"化学和物理检测采样（含感官检测）"},{"_id":"6a5dc9aff1c10c8ce825b3b8","lab_id":"69ad52a3de79e566650fb1f1","country":"PL","accr_number":"AB 386","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"4,0 - 10,0"}],"parameters_en":[{"name":"Range","range":"4,0 - 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 4,0 - 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda pH\nZakres 4,0 - 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda pH\nZakres 4,0 - 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 - 10,0"}],"search_zh":"水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水"},{"_id":"6a5dc9aff1c10c8ce825b3b9","lab_id":"69ad52a3de79e566650fb1f1","country":"PL","accr_number":"AB 386","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Barwa","methodology_en":"Colour","parameters":[{"name":"Zakres","range":"(5 - 50) mg/dm3 Pt"}],"parameters_en":[{"name":"Range","range":"(5 - 50) mg/dm3 Pt"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"technique_en":"Visual method","computed":[],"computed_en":[],"activity":"Barwa\nZakres (5 - 50) mg/dm3 Pt\nMetoda wizualna","reference":"PN-EN ISO 7887:2012 + Ap1:2015-06 metoda D","norm_bases":["PN-EN ISO 7887:2012 + Ap1:2015-06 metoda D"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Barwa\nZakres (5 - 50) mg/dm3 Pt\nMetoda wizualna PN-EN ISO 7887:2012 + Ap1:2015-06 metoda D Woda Barwa\nZakres (5 - 50) mg/dm3 Pt\nMetoda wizualna PN-EN ISO 7887:2012 + Ap1:2015-06 metoda D","categories":["water"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Colour Visual method Range PN-EN ISO 7887:2012 + Ap1:2015-06 metoda D","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(5 - 50) mg/dm3 Pt"}],"search_zh":"水 色度 目视法 范围 PN-EN ISO 7887:2012 + Ap1:2015-06 metoda D","technique_zh":"目视法","test_object_zh":"水"},{"_id":"6a5dc9aff1c10c8ce825b3ba","lab_id":"69ad52a3de79e566650fb1f1","country":"PL","accr_number":"AB 386","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Mętność","methodology_en":"Turbidity","parameters":[{"name":"Zakres","range":"(0,20 - 400) NTU"}],"parameters_en":[{"name":"Range","range":"(0,20 - 400) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"technique_en":"Nephelometric method","computed":[],"computed_en":[],"activity":"Mętność\nZakres (0,20 - 400) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Mętność\nZakres (0,20 - 400) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda Metnosc\nZakres (0,20 - 400) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,20 - 400) NTU"}],"search_zh":"水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"水"},{"_id":"6a5dc9aff1c10c8ce825b3bb","lab_id":"69ad52a3de79e566650fb1f1","country":"PL","accr_number":"AB 386","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Przewodność elektryczna właściwa","methodology_en":"Electrical conductivity","parameters":[{"name":"Zakres","range":"(5 - 2500) μS/cm"}],"parameters_en":[{"name":"Range","range":"(5 - 2500) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"technique_en":"Conductometric method","computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa\nZakres (5 - 2500) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Przewodność elektryczna właściwa\nZakres (5 - 2500) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda Przewodnosc elektryczna wlasciwa\nZakres (5 - 2500) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Electrical conductivity Conductometric method Range PN-EN 27888:1999","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(5 - 2500) μS/cm"}],"search_zh":"水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水"},{"_id":"6a5dc9aff1c10c8ce825b3bc","lab_id":"69ad52a3de79e566650fb1f1","country":"PL","accr_number":"AB 386","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Zasadowość ogólna","methodology_en":"Total alkalinity","parameters":[{"name":"Zakres","range":"(0,4 - 20) mmol/dm3"}],"parameters_en":[{"name":"Range","range":"(0,4 - 20) mmol/dm3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Zasadowość ogólna\nZakres (0,4 - 20) mmol/dm3\nMetoda miareczkowa","reference":"PN-EN ISO 9963-1:2001+Ap1:2004","norm_bases":["PN-EN ISO 9963-1:2001+Ap1:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Zasadowość ogólna\nZakres (0,4 - 20) mmol/dm3\nMetoda miareczkowa PN-EN ISO 9963-1:2001+Ap1:2004 Woda Zasadowosc ogolna\nZakres (0,4 - 20) mmol/dm3\nMetoda miareczkowa PN-EN ISO 9963-1:2001+Ap1:2004","categories":["water"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Total alkalinity Titrimetric method Range PN-EN ISO 9963-1:2001+Ap1:2004","parameters_zh":[{"name":"范围","range":"(0,4 - 20) mmol/dm3"}],"search_zh":"水 总碱度 滴定法 范围 PN-EN ISO 9963-1:2001+Ap1:2004","technique_zh":"滴定法","test_object_zh":"水","methodology_zh":"总碱度"},{"_id":"6a5dc9aff1c10c8ce825b3bd","lab_id":"69ad52a3de79e566650fb1f1","country":"PL","accr_number":"AB 386","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)","methodology_en":"Total content of calcium and magnesium (total hardness)","parameters":[{"name":"Zakres","range":"(5 - 500) mg/dm3 CaCO3"}],"parameters_en":[{"name":"Range","range":"(5 - 500) mg/dm3 CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (5 - 500) mg/dm3 CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (5 - 500) mg/dm3 CaCO3\nMetoda miareczkowa PN-ISO 6059:1999 Woda Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna)\nZakres (5 - 500) mg/dm3 CaCO3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Total content of calcium and magnesium (total hardness) Titrimetric method Range PN-ISO 6059:1999","methodology_zh":"钙与镁总量（总硬度）","parameters_zh":[{"name":"范围","range":"(5 - 500) mg/dm3 CaCO3"}],"search_zh":"水 钙与镁总量（总硬度） 滴定法 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"水"},{"_id":"6a5dc9aff1c10c8ce825b3be","lab_id":"69ad52a3de79e566650fb1f1","country":"PL","accr_number":"AB 386","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie azotu azotynowego","methodology_en":"Nitrite nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,001 - 0,25) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,001 - 0,25) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu azotynowego\nZakres (0,001 - 0,25) mg/dm3\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie azotu azotynowego\nZakres (0,001 - 0,25) mg/dm3\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda Stezenie azotu azotynowego\nZakres (0,001 - 0,25) mg/dm3\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Nitrite nitrogen concentration Spectrophotometric method Range PN-EN 26777:1999","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,001 - 0,25) mg/dm3"}],"search_zh":"水 亚硝态氮浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水"},{"_id":"6a5dc9aff1c10c8ce825b3bf","lab_id":"69ad52a3de79e566650fb1f1","country":"PL","accr_number":"AB 386","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie wapnia","methodology_en":"Calcium concentration","parameters":[{"name":"Zakres","range":"(2 - 100) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(2 - 100) mg/dm3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie wapnia\nZakres (2 - 100) mg/dm3\nMetoda miareczkowa","reference":"PN-ISO 6058:1999","norm_bases":["PN-ISO 6058:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie wapnia\nZakres (2 - 100) mg/dm3\nMetoda miareczkowa PN-ISO 6058:1999 Woda Stezenie wapnia\nZakres (2 - 100) mg/dm3\nMetoda miareczkowa PN-ISO 6058:1999","categories":["water"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Calcium concentration Titrimetric method Range PN-ISO 6058:1999","parameters_zh":[{"name":"范围","range":"(2 - 100) mg/dm3"}],"search_zh":"水 钙浓度 滴定法 范围 PN-ISO 6058:1999","technique_zh":"滴定法","test_object_zh":"水","methodology_zh":"钙浓度"},{"_id":"6a5dc9aff1c10c8ce825b3c0","lab_id":"69ad52a3de79e566650fb1f1","country":"PL","accr_number":"AB 386","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie magnezu (z obliczeń)","methodology_en":"Magnesium concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie magnezu (z obliczeń)","reference":"PN-ISO 6059:1999 | PN-ISO 6058:1999","norm_bases":["PN-ISO 6059:1999","PN-ISO 6058:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie magnezu (z obliczeń) PN-ISO 6059:1999 | PN-ISO 6058:1999 Woda Stezenie magnezu (z obliczen) PN-ISO 6059:1999 | PN-ISO 6058:1999","categories":["water"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Magnesium concentration (calculated) PN-ISO 6059:1999 | PN-ISO 6058:1999","search_zh":"水 镁浓度（计算值） PN-ISO 6059:1999 | PN-ISO 6058:1999","test_object_zh":"水","methodology_zh":"镁浓度（计算值）"},{"_id":"6a5dc9aff1c10c8ce825b3c1","lab_id":"69ad52a3de79e566650fb1f1","country":"PL","accr_number":"AB 386","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie ortofosforanów","methodology_en":"Orthophosphate concentration","parameters":[{"name":"Zakres","range":"(0,030 - 2,45) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,030 - 2,45) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie ortofosforanów\nZakres (0,030 - 2,45) mg/dm3\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 pkt 4 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 pkt 4 +Ap1:2010+Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie ortofosforanów\nZakres (0,030 - 2,45) mg/dm3\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt 4 +Ap1:2010+Ap2:2010 Woda Stezenie ortofosforanow\nZakres (0,030 - 2,45) mg/dm3\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt 4 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Orthophosphate concentration Spectrophotometric method Range PN-EN ISO 6878:2006 pkt 4 +Ap1:2010+Ap2:2010","parameters_zh":[{"name":"范围","range":"(0,030 - 2,45) mg/dm3"}],"search_zh":"水 正磷酸盐浓度 分光光度法 范围 PN-EN ISO 6878:2006 pkt 4 +Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水","methodology_zh":"正磷酸盐浓度"},{"_id":"6a5dc9aff1c10c8ce825b3c2","lab_id":"69ad52a3de79e566650fb1f1","country":"PL","accr_number":"AB 386","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie chlorków","methodology_en":"Chloride concentration","parameters":[{"name":"Zakres","range":"(5 - 400) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(5 - 400) mg/dm3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie chlorków\nZakres (5 - 400) mg/dm3\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie chlorków\nZakres (5 - 400) mg/dm3\nMetoda miareczkowa PN-ISO 9297:1994 Woda Stezenie chlorkow\nZakres (5 - 400) mg/dm3\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Chloride concentration Titrimetric method Range PN-ISO 9297:1994","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5 - 400) mg/dm3"}],"search_zh":"水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水"},{"_id":"6a5dc9aff1c10c8ce825b3c3","lab_id":"69ad52a3de79e566650fb1f1","country":"PL","accr_number":"AB 386","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Liczba progowa zapachu TON","methodology_en":"Odour threshold number TON","parameters":[{"name":"Zakres","range":"(1 – 4)"}],"parameters_en":[{"name":"Range","range":"(1 – 4)"}],"technique":"Metoda uproszczona, parzysta, wybór niewymuszony","techniques":["Metoda uproszczona, parzysta, wybór niewymuszony"],"technique_en":"Simplified method, paired, non-forced choice","computed":[],"computed_en":[],"activity":"Liczba progowa zapachu TON\nZakres (1 – 4)\nMetoda uproszczona, parzysta, wybór niewymuszony","reference":"PN-EN 1622:2006","norm_bases":["PN-EN 1622:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Liczba progowa zapachu TON\nZakres (1 – 4)\nMetoda uproszczona, parzysta, wybór niewymuszony PN-EN 1622:2006 Woda Liczba progowa zapachu TON\nZakres (1 – 4)\nMetoda uproszczona, parzysta, wybor niewymuszony PN-EN 1622:2006","categories":["water"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Odour threshold number TON Simplified method, paired, non-forced choice Range PN-EN 1622:2006","parameters_zh":[{"name":"范围","range":"(1 – 4)"}],"search_zh":"水 嗅阈值 TON 简化法，成对，非强制选择 范围 PN-EN 1622:2006","test_object_zh":"水","technique_zh":"简化法，成对，非强制选择","methodology_zh":"嗅阈值 TON"},{"_id":"6a5dc9aff1c10c8ce825b3c4","lab_id":"69ad52a3de79e566650fb1f1","country":"PL","accr_number":"AB 386","accr_body":"PCA","test_object":"Woda do spożycia","test_object_en":"Drinking water","methodology":"Liczba progowa smaku TFN","methodology_en":"Taste threshold number TFN","parameters":[{"name":"Zakres","range":"(1 – 2)"}],"parameters_en":[{"name":"Range","range":"(1 – 2)"}],"technique":"Metoda uproszczona, parzysta, wybór niewymuszony","techniques":["Metoda uproszczona, parzysta, wybór niewymuszony"],"technique_en":"Simplified method, paired, non-forced choice","computed":[],"computed_en":[],"activity":"Liczba progowa smaku TFN\nZakres (1 – 2)\nMetoda uproszczona, parzysta, wybór niewymuszony","reference":"PN-EN 1622:2006","norm_bases":["PN-EN 1622:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia Liczba progowa smaku TFN\nZakres (1 – 2)\nMetoda uproszczona, parzysta, wybór niewymuszony PN-EN 1622:2006 Woda do spozycia Liczba progowa smaku TFN\nZakres (1 – 2)\nMetoda uproszczona, parzysta, wybor niewymuszony PN-EN 1622:2006","categories":["water"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Drinking water Taste threshold number TFN Simplified method, paired, non-forced choice Range PN-EN 1622:2006","parameters_zh":[{"name":"范围","range":"(1 – 2)"}],"search_zh":"饮用水 味阈值 TFN 简化法，成对，非强制选择 范围 PN-EN 1622:2006","technique_zh":"简化法，成对，非强制选择","methodology_zh":"味阈值 TFN","test_object_zh":"饮用水"},{"_id":"6a5dc9aff1c10c8ce825b3c5","lab_id":"69ad52a3de79e566650fb1f1","country":"PL","accr_number":"AB 386","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie chlorowcowych pochodnych węglowodorów","methodology_en":"Concentration of halogenated hydrocarbon derivatives","parameters":[{"name":"Chloroform (1,0-100) μg/dm3"},{"name":"Bromodichlorometan (1,0-100) μg/dm3"},{"name":"Dibromochlorometan (1,0-100) μg/dm3"},{"name":"Bromoform (1,0-100) μg/dm3"},{"name":"Tetrachlorometan (1,0-100) μg/dm3"},{"name":"Trichloroeten (1,0-100) μg/dm3"},{"name":"Tetrachloroeten (1,0-100) μg/dm3 1,2 dichloroetan (0,9-100) μg/dm3"},{"name":"Suma THM (z obliczeń) Suma trichloroetenu i tetrachloroetenu (z obliczeń)"}],"parameters_en":[{"name":"Chloroform (1,0-100) μg/dm3"},{"name":"Bromodichloromethane (1,0-100) μg/dm3"},{"name":"Dibromochloromethane (1,0-100) μg/dm3"},{"name":"Bromoform (1,0-100) μg/dm3"},{"name":"Tetrachloromethane (1,0-100) μg/dm3"},{"name":"Trichloroethene (1,0-100) μg/dm3"},{"name":"Tetrachloroethene (1,0-100) μg/dm3 1,2 dichloroethane (0,9-100) μg/dm3"},{"name":"Sum of THM (calculated) Sum of trichloroethene and tetrachloroethene (calculated)"}],"technique":"Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej z detekcją wychwytu elektronów (HS-GC-ECD)","techniques":["Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej z detekcją wychwytu elektronów (HS-GC-ECD)"],"technique_en":"Headspace gas chromatography with electron capture detection (HS-GC-ECD)","computed":[],"computed_en":[],"activity":"Stężenie chlorowcowych pochodnych węglowodorów\nZakres:\nChloroform (1,0-100) μg/dm3\nBromodichlorometan (1,0-100) μg/dm3\nDibromochlorometan (1,0-100) μg/dm3\nBromoform (1,0-100) μg/dm3\nTetrachlorometan (1,0-100) μg/dm3\nTrichloroeten (1,0-100) μg/dm3\nTetrachloroeten (1,0-100) μg/dm3 1,2 dichloroetan (0,9-100) μg/dm3\nSuma THM (z obliczeń) Suma trichloroetenu i tetrachloroetenu (z obliczeń)\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej z detekcją wychwytu elektronów (HS-GC-ECD)","reference":"PN-EN ISO 10301:2002","norm_bases":["PN-EN ISO 10301:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie chlorowcowych pochodnych węglowodorów\nZakres:\nChloroform (1,0-100) μg/dm3\nBromodichlorometan (1,0-100) μg/dm3\nDibromochlorometan (1,0-100) μg/dm3\nBromoform (1,0-100) μg/dm3\nTetrachlorometan (1,0-100) μg/dm3\nTrichloroeten (1,0-100) μg/dm3\nTetrachloroeten (1,0-100) μg/dm3 1,2 dichloroetan (0,9-100) μg/dm3\nSuma THM (z obliczeń) Suma trichloroetenu i tetrachloroetenu (z obliczeń)\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej z detekcją wychwytu elektronów (HS-GC-ECD) PN-EN ISO 10301:2002 Woda Stezenie chlorowcowych pochodnych weglowodorow\nZakres:\nChloroform (1,0-100) μg/dm3\nBromodichlorometan (1,0-100) μg/dm3\nDibromochlorometan (1,0-100) μg/dm3\nBromoform (1,0-100) μg/dm3\nTetrachlorometan (1,0-100) μg/dm3\nTrichloroeten (1,0-100) μg/dm3\nTetrachloroeten (1,0-100) μg/dm3 1,2 dichloroetan (0,9-100) μg/dm3\nSuma THM (z obliczen) Suma trichloroetenu i tetrachloroetenu (z obliczen)\nMetoda chromatografii gazowej z analiza fazy nadpowierzchniowej z detekcja wychwytu elektronow (HS-GC-ECD) PN-EN ISO 10301:2002","categories":["water"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Concentration of halogenated hydrocarbon derivatives Headspace gas chromatography with electron capture detection (HS-GC-ECD) Chloroform (1,0-100) μg/dm3 Bromodichloromethane (1,0-100) μg/dm3 Dibromochloromethane (1,0-100) μg/dm3 Bromoform (1,0-100) μg/dm3 Tetrachloromethane (1,0-100) μg/dm3 Trichloroethene (1,0-100) μg/dm3 Tetrachloroethene (1,0-100) μg/dm3 1,2 dichloroethane (0,9-100) μg/dm3 Sum of THM (calculated) Sum of trichloroethene and tetrachloroethene (calculated) PN-EN ISO 10301:2002","search_zh":"水 卤代烃浓度 PN-EN ISO 10301:2002","test_object_zh":"水","methodology_zh":"卤代烃浓度"},{"_id":"6a5dc9aff1c10c8ce825b3c6","lab_id":"69ad52a3de79e566650fb1f1","country":"PL","accr_number":"AB 386","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie pierwiastków","methodology_en":"Element concentration","parameters":[{"name":"Mangan","range":"(5,0 – 2000) μg/dm3"},{"name":"Sód","range":"(1,00 – 200) mg/dm3"},{"name":"Potas","range":"(0,50 – 100) mg/dm3"},{"name":"Bor","range":"(0,200 – 2,0) mg/dm3"},{"name":"Srebro","range":"(0,0030 – 0,100) mg/dm3"}],"parameters_en":[{"name":"Manganese","range":"(5,0 – 2000) μg/dm3"},{"name":"Sodium","range":"(1,00 – 200) mg/dm3"},{"name":"Potassium","range":"(0,50 – 100) mg/dm3"},{"name":"Boron","range":"(0,200 – 2,0) mg/dm3"},{"name":"Silver","range":"(0,0030 – 0,100) mg/dm3"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","computed":[],"computed_en":[],"activity":"Stężenie pierwiastków\nZakres:\nMangan (5,0 – 2000) μg/dm3\nSód (1,00 – 200) mg/dm3\nPotas (0,50 – 100) mg/dm3\nBor (0,200 – 2,0) mg/dm3\nSrebro (0,0030 – 0,100) mg/dm3\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie pierwiastków\nZakres:\nMangan (5,0 – 2000) μg/dm3\nSód (1,00 – 200) mg/dm3\nPotas (0,50 – 100) mg/dm3\nBor (0,200 – 2,0) mg/dm3\nSrebro (0,0030 – 0,100) mg/dm3\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Woda Stezenie pierwiastkow\nZakres:\nMangan (5,0 – 2000) μg/dm3\nSod (1,00 – 200) mg/dm3\nPotas (0,50 – 100) mg/dm3\nBor (0,200 – 2,0) mg/dm3\nSrebro (0,0030 – 0,100) mg/dm3\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["water"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Element concentration Inductively coupled plasma optical emission spectrometry (ICP-OES) Manganese Sodium Potassium Boron Silver PN-EN ISO 11885:2009","methodology_zh":"元素浓度","search_zh":"水 元素浓度 电感耦合等离子体原子发射光谱法（ICP-OES） 锰 钠 钾 硼 银 PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"水","parameters_zh":[{"name":"锰","range":"(5,0 – 2000) μg/dm3"},{"name":"钠","range":"(1,00 – 200) mg/dm3"},{"name":"钾","range":"(0,50 – 100) mg/dm3"},{"name":"硼","range":"(0,200 – 2,0) mg/dm3"},{"name":"银","range":"(0,0030 – 0,100) mg/dm3"}]},{"_id":"6a5dc9aff1c10c8ce825b3c7","lab_id":"69ad52a3de79e566650fb1f1","country":"PL","accr_number":"AB 386","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie pierwiastków","methodology_en":"Element concentration","parameters":[{"name":"Antymon","range":"(1,5 – 50,0) μg/dm3"},{"name":"Arsen","range":"(3,0 – 50,0) μg/dm3"},{"name":"Selen","range":"(3,0 – 50,0) μg/dm3"}],"parameters_en":[{"name":"Antimony","range":"(1,5 – 50,0) μg/dm3"},{"name":"Arsenic","range":"(3,0 – 50,0) μg/dm3"},{"name":"Selenium","range":"(3,0 – 50,0) μg/dm3"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES)"],"technique_en":"Hydride generation inductively coupled plasma optical emission spectrometry (HG-ICP-OES)","computed":[],"computed_en":[],"activity":"Stężenie pierwiastków\nZakres:\nAntymon (1,5 – 50,0) μg/dm3\nArsen (3,0 – 50,0) μg/dm3\nSelen (3,0 – 50,0) μg/dm3\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie pierwiastków\nZakres:\nAntymon (1,5 – 50,0) μg/dm3\nArsen (3,0 – 50,0) μg/dm3\nSelen (3,0 – 50,0) μg/dm3\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES) PN-EN ISO 11885:2009 Woda Stezenie pierwiastkow\nZakres:\nAntymon (1,5 – 50,0) μg/dm3\nArsen (3,0 – 50,0) μg/dm3\nSelen (3,0 – 50,0) μg/dm3\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej z generowaniem wodorkow (HG-ICP-OES) PN-EN ISO 11885:2009","categories":["water"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Element concentration Hydride generation inductively coupled plasma optical emission spectrometry (HG-ICP-OES) Antimony Arsenic Selenium PN-EN ISO 11885:2009","methodology_zh":"元素浓度","search_zh":"水 元素浓度 氢化物发生电感耦合等离子体发射光谱法（HG-ICP-OES） 锑 砷 硒 PN-EN ISO 11885:2009","test_object_zh":"水","parameters_zh":[{"name":"锑","range":"(1,5 – 50,0) μg/dm3"},{"name":"砷","range":"(3,0 – 50,0) μg/dm3"},{"name":"硒","range":"(3,0 – 50,0) μg/dm3"}],"technique_zh":"氢化物发生电感耦合等离子体发射光谱法（HG-ICP-OES）"},{"_id":"6a5dc9aff1c10c8ce825b3c8","lab_id":"69ad52a3de79e566650fb1f1","country":"PL","accr_number":"AB 386","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie rtęci","methodology_en":"Mercury concentration","parameters":[{"name":"Zakres","range":"(0,3 – 3,0) μg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,3 – 3,0) μg/dm3"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem zimnych par (CV-ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem zimnych par (CV-ICP-OES)"],"technique_en":"Inductively coupled plasma atomic emission spectrometry with cold vapour generation (CV-ICP-OES)","computed":[],"computed_en":[],"activity":"Stężenie rtęci\nZakres (0,3 – 3,0) μg/dm3\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem zimnych par (CV-ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie rtęci\nZakres (0,3 – 3,0) μg/dm3\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem zimnych par (CV-ICP-OES) PN-EN ISO 11885:2009 Woda Stezenie rteci\nZakres (0,3 – 3,0) μg/dm3\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej z generowaniem zimnych par (CV-ICP-OES) PN-EN ISO 11885:2009","categories":["water"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Mercury concentration Inductively coupled plasma atomic emission spectrometry with cold vapour generation (CV-ICP-OES) Range PN-EN ISO 11885:2009","methodology_zh":"汞浓度","parameters_zh":[{"name":"范围","range":"(0,3 – 3,0) μg/dm3"}],"search_zh":"水 汞浓度 范围 PN-EN ISO 11885:2009","test_object_zh":"水"},{"_id":"6a5dc9aff1c10c8ce825b3c9","lab_id":"69ad52a3de79e566650fb1f1","country":"PL","accr_number":"AB 386","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie kationów","methodology_en":"Cation concentrations","parameters":[{"name":"amonowy","range":"(0,025 - 1,0) mg/dm3"},{"name":"wapnia","range":"(2,0 - 100) mg/dm3"},{"name":"magnezu","range":"(1,2 - 150) mg/dm3"},{"name":"Twardość ogólna (z obliczeń)"}],"parameters_en":[{"name":"ammonium","range":"(0,025 - 1,0) mg/dm3"},{"name":"calcium","range":"(2,0 - 100) mg/dm3"},{"name":"magnesium","range":"(1,2 - 150) mg/dm3"},{"name":"Total hardness (calculated)"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"technique_en":"Ion chromatography with conductometric detection (IC-CD)","computed":[],"computed_en":[],"activity":"Stężenie kationów\nZakres:\namonowy (0,025 - 1,0) mg/dm3\nwapnia (2,0 - 100) mg/dm3\nmagnezu (1,2 - 150) mg/dm3\nTwardość ogólna (z obliczeń)\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 14911:2002","norm_bases":["PN-EN ISO 14911:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie kationów\nZakres:\namonowy (0,025 - 1,0) mg/dm3\nwapnia (2,0 - 100) mg/dm3\nmagnezu (1,2 - 150) mg/dm3\nTwardość ogólna (z obliczeń)\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 14911:2002 Woda Stezenie kationow\nZakres:\namonowy (0,025 - 1,0) mg/dm3\nwapnia (2,0 - 100) mg/dm3\nmagnezu (1,2 - 150) mg/dm3\nTwardosc ogolna (z obliczen)\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 14911:2002","categories":["water"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Cation concentrations Ion chromatography with conductometric detection (IC-CD) ammonium calcium magnesium Total hardness (calculated) PN-EN ISO 14911:2002","search_zh":"水 阳离子浓度 离子色谱-电导检测法（IC-CD） 铵态 总硬度（由计算得出） PN-EN ISO 14911:2002","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水","parameters_zh":[{"name":"铵态","range":"(0,025 - 1,0) mg/dm3"},{"name":"wapnia","range":"(2,0 - 100) mg/dm3"},{"name":"magnezu","range":"(1,2 - 150) mg/dm3"},{"name":"总硬度（由计算得出）"}],"methodology_zh":"阳离子浓度"},{"_id":"6a5dc9aff1c10c8ce825b3ca","lab_id":"69ad52a3de79e566650fb1f1","country":"PL","accr_number":"AB 386","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie anionów","methodology_en":"Anion concentrations","parameters":[{"name":"fluorki","range":"(0,10 – 5,0) mg/dm3"},{"name":"siarczany","range":"(5,0 - 250) mg/dm3"},{"name":"bromki","range":"(0,02 - 2,0) mg/dm3"},{"name":"azotany","range":"(0,50 - 50) mg/dm3"},{"name":"chlorki","range":"(5,0 - 250) mg/dm3"},{"name":"fosforany","range":"(0,03 - 2,5) mg/dm3"},{"name":"azotyny","range":"(0,003 – 1,0) mg/dm3"}],"parameters_en":[{"name":"fluorides","range":"(0,10 – 5,0) mg/dm3"},{"name":"sulfates","range":"(5,0 - 250) mg/dm3"},{"name":"bromides","range":"(0,02 - 2,0) mg/dm3"},{"name":"nitrates","range":"(0,50 - 50) mg/dm3"},{"name":"chlorides","range":"(5,0 - 250) mg/dm3"},{"name":"phosphates","range":"(0,03 - 2,5) mg/dm3"},{"name":"nitrites","range":"(0,003 – 1,0) mg/dm3"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"technique_en":"Ion chromatography with conductometric detection (IC-CD)","computed":[],"computed_en":[],"activity":"Stężenie anionów\nZakres:\nfluorki (0,10 – 5,0) mg/dm3\nsiarczany (5,0 - 250) mg/dm3\nbromki (0,02 - 2,0) mg/dm3\nazotany (0,50 - 50) mg/dm3\nchlorki (5,0 - 250) mg/dm3\nfosforany (0,03 - 2,5) mg/dm3\nazotyny (0,003 – 1,0) mg/dm3\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie anionów\nZakres:\nfluorki (0,10 – 5,0) mg/dm3\nsiarczany (5,0 - 250) mg/dm3\nbromki (0,02 - 2,0) mg/dm3\nazotany (0,50 - 50) mg/dm3\nchlorki (5,0 - 250) mg/dm3\nfosforany (0,03 - 2,5) mg/dm3\nazotyny (0,003 – 1,0) mg/dm3\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Woda Stezenie anionow\nZakres:\nfluorki (0,10 – 5,0) mg/dm3\nsiarczany (5,0 - 250) mg/dm3\nbromki (0,02 - 2,0) mg/dm3\nazotany (0,50 - 50) mg/dm3\nchlorki (5,0 - 250) mg/dm3\nfosforany (0,03 - 2,5) mg/dm3\nazotyny (0,003 – 1,0) mg/dm3\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Anion concentrations Ion chromatography with conductometric detection (IC-CD) fluorides sulfates bromides nitrates chlorides phosphates nitrites PN-EN ISO 10304-1:2009+AC:2012","methodology_zh":"阴离子浓度","search_zh":"水 阴离子浓度 离子色谱-电导检测法（IC-CD） 氟化物 硫酸盐 溴化物 硝酸盐 氯化物 磷酸盐 亚硝酸盐 PN-EN ISO 10304-1:2009+AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水","parameters_zh":[{"name":"氟化物","range":"(0,10 – 5,0) mg/dm3"},{"name":"硫酸盐","range":"(5,0 - 250) mg/dm3"},{"name":"溴化物","range":"(0,02 - 2,0) mg/dm3"},{"name":"硝酸盐","range":"(0,50 - 50) mg/dm3"},{"name":"氯化物","range":"(5,0 - 250) mg/dm3"},{"name":"磷酸盐","range":"(0,03 - 2,5) mg/dm3"},{"name":"亚硝酸盐","range":"(0,003 – 1,0) mg/dm3"}]},{"_id":"6a5dc9aff1c10c8ce825b3cb","lab_id":"69ad52a3de79e566650fb1f1","country":"PL","accr_number":"AB 386","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie anionów","methodology_en":"Anion concentrations","parameters":[{"name":"chloryny","range":"(0,01 - 1,0) mg/dm3"},{"name":"chlorany","range":"(0,01 - 1,0) mg/dm3"},{"name":"Suma chlorynów i chloranów (z obliczeń)"}],"parameters_en":[{"name":"chlorites","range":"(0,01 - 1,0) mg/dm3"},{"name":"chlorates","range":"(0,01 - 1,0) mg/dm3"},{"name":"Sum of chlorites and chlorates (calculated)"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"technique_en":"Ion chromatography with conductometric detection (IC-CD)","computed":[],"computed_en":[],"activity":"Stężenie anionów\nZakres:\nchloryny (0,01 - 1,0) mg/dm3\nchlorany (0,01 - 1,0) mg/dm3\nSuma chlorynów i chloranów (z obliczeń)\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-4:2022-08","norm_bases":["PN-EN ISO 10304-4:2022-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie anionów\nZakres:\nchloryny (0,01 - 1,0) mg/dm3\nchlorany (0,01 - 1,0) mg/dm3\nSuma chlorynów i chloranów (z obliczeń)\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-4:2022-08 Woda Stezenie anionow\nZakres:\nchloryny (0,01 - 1,0) mg/dm3\nchlorany (0,01 - 1,0) mg/dm3\nSuma chlorynow i chloranow (z obliczen)\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-4:2022-08","categories":["water"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Anion concentrations Ion chromatography with conductometric detection (IC-CD) chlorites chlorates Sum of chlorites and chlorates (calculated) PN-EN ISO 10304-4:2022-08","methodology_zh":"阴离子浓度","search_zh":"水 阴离子浓度 离子色谱-电导检测法（IC-CD） 亚氯酸盐 氯酸盐 亚氯酸盐与氯酸盐总量（由计算得出） PN-EN ISO 10304-4:2022-08","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水","parameters_zh":[{"name":"亚氯酸盐","range":"(0,01 - 1,0) mg/dm3"},{"name":"氯酸盐","range":"(0,01 - 1,0) mg/dm3"},{"name":"亚氯酸盐与氯酸盐总量（由计算得出）"}]},{"_id":"6a5dc9aff1c10c8ce825b3cc","lab_id":"69ad52a3de79e566650fb1f1","country":"PL","accr_number":"AB 386","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie bromianów","methodology_en":"Bromate concentration","parameters":[{"name":"Zakres","range":"(0,001 - 0,05) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,001 - 0,05) mg/dm3"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"technique_en":"Ion chromatography with conductometric detection (IC-CD)","computed":[],"computed_en":[],"activity":"Stężenie bromianów\nZakres (0,001 - 0,05) mg/dm3\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 15061:2003","norm_bases":["PN-EN ISO 15061:2003"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie bromianów\nZakres (0,001 - 0,05) mg/dm3\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 15061:2003 Woda Stezenie bromianow\nZakres (0,001 - 0,05) mg/dm3\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 15061:2003","categories":["water"],"row_index":21,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Bromate concentration Ion chromatography with conductometric detection (IC-CD) Range PN-EN ISO 15061:2003","parameters_zh":[{"name":"范围","range":"(0,001 - 0,05) mg/dm3"}],"search_zh":"水 溴酸盐浓度 离子色谱-电导检测法（IC-CD） 范围 PN-EN ISO 15061:2003","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水","methodology_zh":"溴酸盐浓度"},{"_id":"6a5dc9aff1c10c8ce825b3cd","lab_id":"69ad52a3de79e566650fb1f1","country":"PL","accr_number":"AB 386","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie pierwiastków","methodology_en":"Element concentration","parameters":[{"name":"Miedź","range":"(3,0 – 5000) μg/dm3"},{"name":"Chrom","range":"(3,0 – 5000) μg/dm3"},{"name":"Nikiel","range":"(3,0 – 5000) μg/dm3"},{"name":"Ołów","range":"(3,0 – 100) μg/dm3"},{"name":"Kadm","range":"(1,0 – 100) μg/dm3"},{"name":"Cynk","range":"(50,0 – 5000) μg/dm3"},{"name":"Glin","range":"(20,0 – 200) μg/dm3"},{"name":"Żelazo","range":"(20,0 – 20000) μg/dm3"}],"parameters_en":[{"name":"Copper","range":"(3,0 – 5000) μg/dm3"},{"name":"Chromium","range":"(3,0 – 5000) μg/dm3"},{"name":"Nickel","range":"(3,0 – 5000) μg/dm3"},{"name":"Lead","range":"(3,0 – 100) μg/dm3"},{"name":"Cadmium","range":"(1,0 – 100) μg/dm3"},{"name":"Zinc","range":"(50,0 – 5000) μg/dm3"},{"name":"Aluminium","range":"(20,0 – 200) μg/dm3"},{"name":"Iron","range":"(20,0 – 20000) μg/dm3"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","computed":[],"computed_en":[],"activity":"Stężenie pierwiastków\nZakres:\nMiedź (3,0 – 5000) μg/dm3\nChrom (3,0 – 5000) μg/dm3\nNikiel (3,0 – 5000) μg/dm3\nOłów (3,0 – 100) μg/dm3\nKadm (1,0 – 100) μg/dm3\nCynk (50,0 – 5000) μg/dm3\nGlin (20,0 – 200) μg/dm3\nŻelazo (20,0 – 20000) μg/dm3\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie pierwiastków\nZakres:\nMiedź (3,0 – 5000) μg/dm3\nChrom (3,0 – 5000) μg/dm3\nNikiel (3,0 – 5000) μg/dm3\nOłów (3,0 – 100) μg/dm3\nKadm (1,0 – 100) μg/dm3\nCynk (50,0 – 5000) μg/dm3\nGlin (20,0 – 200) μg/dm3\nŻelazo (20,0 – 20000) μg/dm3\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Woda, scieki Stezenie pierwiastkow\nZakres:\nMiedz (3,0 – 5000) μg/dm3\nChrom (3,0 – 5000) μg/dm3\nNikiel (3,0 – 5000) μg/dm3\nOlow (3,0 – 100) μg/dm3\nKadm (1,0 – 100) μg/dm3\nCynk (50,0 – 5000) μg/dm3\nGlin (20,0 – 200) μg/dm3\nZelazo (20,0 – 20000) μg/dm3\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["water","materials"],"row_index":22,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Element concentration Inductively coupled plasma optical emission spectrometry (ICP-OES) Copper Chromium Nickel Lead Cadmium Zinc Aluminium Iron PN-EN ISO 11885:2009","methodology_zh":"元素浓度","parameters_zh":[{"name":"铜","range":"(3,0 – 5000) μg/dm3"},{"name":"铬","range":"(3,0 – 5000) μg/dm3"},{"name":"镍","range":"(3,0 – 5000) μg/dm3"},{"name":"铅","range":"(3,0 – 100) μg/dm3"},{"name":"镉","range":"(1,0 – 100) μg/dm3"},{"name":"锌","range":"(50,0 – 5000) μg/dm3"},{"name":"铝","range":"(20,0 – 200) μg/dm3"},{"name":"铁","range":"(20,0 – 20000) μg/dm3"}],"search_zh":"水、废水 元素浓度 电感耦合等离子体原子发射光谱法（ICP-OES） 铜 铬 镍 铅 镉 锌 铝 铁 PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"水、废水"},{"_id":"6a5dc9aff1c10c8ce825b3ce","lab_id":"69ad52a3de79e566650fb1f1","country":"PL","accr_number":"AB 386","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie żelaza","methodology_en":"Iron concentration","parameters":[{"name":"Zakres","range":"(50 - 10000) μg/dm3"}],"parameters_en":[{"name":"Range","range":"(50 - 10000) μg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie żelaza\nZakres (50 - 10000) μg/dm3\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001+Ap1:2016-06","norm_bases":["PN-ISO 6332:2001+Ap1:2016-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie żelaza\nZakres (50 - 10000) μg/dm3\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06 Woda, scieki Stezenie zelaza\nZakres (50 - 10000) μg/dm3\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06","categories":["water"],"row_index":23,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Iron concentration Spectrophotometric method Range PN-ISO 6332:2001+Ap1:2016-06","methodology_zh":"铁浓度","parameters_zh":[{"name":"范围","range":"(50 - 10000) μg/dm3"}],"search_zh":"水、废水 铁浓度 分光光度法 范围 PN-ISO 6332:2001+Ap1:2016-06","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a5dc9aff1c10c8ce825b3cf","lab_id":"69ad52a3de79e566650fb1f1","country":"PL","accr_number":"AB 386","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie ogólnego węgla organicznego","methodology_en":"Total organic carbon concentration","parameters":[{"name":"Zakres","range":"(1,0 - 100) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(1,0 - 100) mg/dm3"}],"technique":"Metoda spektrometrii w zakresie podczerwieni IR","techniques":["Metoda spektrometrii w zakresie podczerwieni IR"],"technique_en":"Spectrometry method in the infrared range IR","computed":[],"computed_en":[],"activity":"Stężenie ogólnego węgla organicznego\nZakres (1,0 - 100) mg/dm3\nMetoda spektrometrii w zakresie podczerwieni IR","reference":"PN-EN 1484:1999","norm_bases":["PN-EN 1484:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie ogólnego węgla organicznego\nZakres (1,0 - 100) mg/dm3\nMetoda spektrometrii w zakresie podczerwieni IR PN-EN 1484:1999 Woda, scieki Stezenie ogolnego wegla organicznego\nZakres (1,0 - 100) mg/dm3\nMetoda spektrometrii w zakresie podczerwieni IR PN-EN 1484:1999","categories":["water"],"row_index":24,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Total organic carbon concentration Spectrometry method in the infrared range IR Range PN-EN 1484:1999","parameters_zh":[{"name":"范围","range":"(1,0 - 100) mg/dm3"}],"search_zh":"水、废水 总有机碳浓度 红外光谱法 IR 范围 PN-EN 1484:1999","test_object_zh":"水、废水","technique_zh":"红外光谱法 IR","methodology_zh":"总有机碳浓度"},{"_id":"6a5dc9aff1c10c8ce825b3d0","lab_id":"69ad52a3de79e566650fb1f1","country":"PL","accr_number":"AB 386","accr_body":"PCA","test_object":"Ścieki, w tym wody roztopowe i opadowe","test_object_en":"Wastewater, including snowmelt and rainwater","methodology":"Indeks oleju mineralnego","methodology_en":"Mineral oil index","parameters":[{"name":"Zakres","range":"(6,0 - 20) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(6,0 - 20) mg/dm3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Indeks oleju mineralnego\nZakres (6,0 - 20) mg/dm3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN ISO 9377-2:2003","norm_bases":["PN-EN ISO 9377-2:2003"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, w tym wody roztopowe i opadowe Indeks oleju mineralnego\nZakres (6,0 - 20) mg/dm3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN ISO 9377-2:2003 Scieki, w tym wody roztopowe i opadowe Indeks oleju mineralnego\nZakres (6,0 - 20) mg/dm3\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN ISO 9377-2:2003","categories":["water","petro"],"row_index":25,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, including snowmelt and rainwater Mineral oil index Gas chromatography with flame ionization detection (GC-FID) Range PN-EN ISO 9377-2:2003","parameters_zh":[{"name":"范围","range":"(6,0 - 20) mg/dm3"}],"search_zh":"矿物油指数 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-EN ISO 9377-2:2003","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","methodology_zh":"矿物油指数"},{"_id":"6a5dc9aff1c10c8ce825b3d1","lab_id":"69ad52a3de79e566650fb1f1","country":"PL","accr_number":"AB 386","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Pobieranie próbek do badań mikrobiologicznych","methodology_en":"Sampling for microbiological testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.2, 4.4.3, 4.4.5, 4.4.6","norm_bases":["PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.2, 4.4.3, 4.4.5, 4.4.6"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.2, 4.4.3, 4.4.5, 4.4.6 Woda Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007 z wylaczeniem pkt. 4.4.2, 4.4.3, 4.4.5, 4.4.6","categories":["water","microbiology"],"row_index":26,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Sampling for microbiological testing PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.2, 4.4.3, 4.4.5, 4.4.6","methodology_zh":"微生物检测用样品采集","search_zh":"水 微生物检测用样品采集 PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.2, 4.4.3, 4.4.5, 4.4.6","test_object_zh":"水"},{"_id":"6a5dc9aff1c10c8ce825b3d2","lab_id":"69ad52a3de79e566650fb1f1","country":"PL","accr_number":"AB 386","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Ogólna liczba mikroorganizmów w 220C","methodology_en":"Total microorganism count at 220C","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa, posiew wgłębny","techniques":["Metoda płytkowa, posiew wgłębny"],"technique_en":"Plate method, pour plate","computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w 220C\nMetoda płytkowa, posiew wgłębny","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ogólna liczba mikroorganizmów w 220C\nMetoda płytkowa, posiew wgłębny PN-EN ISO 6222:2004 Woda Ogolna liczba mikroorganizmow w 220C\nMetoda plytkowa, posiew wglebny PN-EN ISO 6222:2004","categories":["water"],"row_index":27,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Total microorganism count at 220C Plate method, pour plate PN-EN ISO 6222:2004","search_zh":"水 22°C 微生物总数 平板法，倾注平板 PN-EN ISO 6222:2004","test_object_zh":"水","technique_zh":"平板法，倾注平板","methodology_zh":"22°C 微生物总数"},{"_id":"6a5dc9aff1c10c8ce825b3d3","lab_id":"69ad52a3de79e566650fb1f1","country":"PL","accr_number":"AB 386","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Ogólna liczba mikroorganizmów w 360C","methodology_en":"Total microorganism count at 360C","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa, posiew wgłębny","techniques":["Metoda płytkowa, posiew wgłębny"],"technique_en":"Plate method, pour plate","computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w 360C\nMetoda płytkowa, posiew wgłębny","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ogólna liczba mikroorganizmów w 360C\nMetoda płytkowa, posiew wgłębny PN-EN ISO 6222:2004 Woda Ogolna liczba mikroorganizmow w 360C\nMetoda plytkowa, posiew wglebny PN-EN ISO 6222:2004","categories":["water"],"row_index":28,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Total microorganism count at 360C Plate method, pour plate PN-EN ISO 6222:2004","search_zh":"水 36°C 微生物总数 平板法，倾注平板 PN-EN ISO 6222:2004","test_object_zh":"水","technique_zh":"平板法，倾注平板","methodology_zh":"36°C 微生物总数"},{"_id":"6a5dc9aff1c10c8ce825b3d4","lab_id":"69ad52a3de79e566650fb1f1","country":"PL","accr_number":"AB 386","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Liczba bakterii grupy coli","methodology_en":"Coliform bacteria count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":29,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04","methodology_zh":"大肠菌群计数","search_zh":"水 大肠菌群计数 膜过滤法 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水"},{"_id":"6a5dc9aff1c10c8ce825b3d5","lab_id":"69ad52a3de79e566650fb1f1","country":"PL","accr_number":"AB 386","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Liczba bakterii Escherichia coli","methodology_en":"Escherichia coli count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba bakterii Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Liczba bakterii Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda Liczba bakterii Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["microbiology","water"],"row_index":30,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水"},{"_id":"6a5dc9aff1c10c8ce825b3d6","lab_id":"69ad52a3de79e566650fb1f1","country":"PL","accr_number":"AB 386","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Liczba Enterokoków kałowych","methodology_en":"Intestinal enterococci count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Enterokoków kałowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Liczba Enterokoków kałowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda Liczba Enterokokow kalowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":31,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004","search_zh":"水 粪肠球菌数 膜过滤法 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"水","methodology_zh":"粪肠球菌数"},{"_id":"6a5dc9aff1c10c8ce825b3d7","lab_id":"69ad52a3de79e566650fb1f1","country":"PL","accr_number":"AB 386","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Najbardziej prawdopodobna liczba bakterii grupy coli","methodology_en":"Most probable number of coliform bacteria","parameters":[],"parameters_en":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"technique_en":"MPN method","computed":[],"computed_en":[],"activity":"Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL PN-EN ISO 9308-2:2014-06 Woda Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL PN-EN ISO 9308-2:2014-06","categories":["water","microbiology"],"row_index":32,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Most probable number of coliform bacteria MPN method PN-EN ISO 9308-2:2014-06","methodology_zh":"大肠菌群最可能数（MPN）","search_zh":"水 大肠菌群最可能数（MPN） 最可能数法（MPN） PN-EN ISO 9308-2:2014-06","technique_zh":"最可能数法（MPN）","test_object_zh":"水"},{"_id":"6a5dc9aff1c10c8ce825b3d8","lab_id":"69ad52a3de79e566650fb1f1","country":"PL","accr_number":"AB 386","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Najbardziej prawdopodobna liczba, Escherichia coli","methodology_en":"Most probable number, Escherichia coli","parameters":[],"parameters_en":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"technique_en":"MPN method","computed":[],"computed_en":[],"activity":"Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda NPL","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda NPL PN-EN ISO 9308-2:2014-06 Woda Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda NPL PN-EN ISO 9308-2:2014-06","categories":["water","microbiology"],"row_index":33,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Most probable number, Escherichia coli MPN method PN-EN ISO 9308-2:2014-06","methodology_zh":"大肠埃希氏菌（Escherichia coli）最可能数（MPN）","search_zh":"水 大肠埃希氏菌（Escherichia coli）最可能数（MPN） 最可能数法（MPN） PN-EN ISO 9308-2:2014-06","technique_zh":"最可能数法（MPN）","test_object_zh":"水"},{"_id":"6a5dc9aff1c10c8ce825b3d9","lab_id":"69ad52a3de79e566650fb1f1","country":"PL","accr_number":"AB 386","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":"Metoda automatyczna","techniques":["Metoda automatyczna"],"technique_en":"Automatic method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda automatyczna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nMetoda automatyczna PN-ISO 5667-10:2021-11 Scieki Pobieranie probek do badan chemicznych i fizycznych\nMetoda automatyczna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":34,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Sampling for chemical and physical testing Automatic method PN-ISO 5667-10:2021-11","methodology_zh":"化学与物理检测用样品采集","search_zh":"污水 化学与物理检测用样品采集 自动法 PN-ISO 5667-10:2021-11","test_object_zh":"污水","technique_zh":"自动法"},{"_id":"6a5dc9aff1c10c8ce825b3da","lab_id":"69ad52a3de79e566650fb1f1","country":"PL","accr_number":"AB 386","accr_body":"PCA","test_object":"Ścieki, w tym wody roztopowe i opadowe","test_object_en":"Wastewater, including snowmelt and rainwater","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":"Metoda manualna","techniques":["Metoda manualna"],"technique_en":"Manual method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, w tym wody roztopowe i opadowe Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna PN-ISO 5667-10:2021-11 Scieki, w tym wody roztopowe i opadowe Pobieranie probek do badan chemicznych i fizycznych\nMetoda manualna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":35,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, including snowmelt and rainwater Sampling for chemical and physical testing Manual method PN-ISO 5667-10:2021-11","methodology_zh":"化学与物理检测用样品采集","search_zh":"化学与物理检测用样品采集 手工法 PN-ISO 5667-10:2021-11","technique_zh":"手工法"},{"_id":"6a5dc9aff1c10c8ce825b3db","lab_id":"69ad52a3de79e566650fb1f1","country":"PL","accr_number":"AB 386","accr_body":"PCA","test_object":"Ścieki, w tym wody roztopowe i opadowe","test_object_en":"Wastewater, including snowmelt and rainwater","methodology":"Zawiesiny ogólne","methodology_en":"Total suspended solids (TSS)","parameters":[{"name":"Zakres","range":"(2,0 - 2000) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(2,0 - 2000) mg/dm3"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawiesiny ogólne\nZakres (2,0 - 2000) mg/dm3\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, w tym wody roztopowe i opadowe Zawiesiny ogólne\nZakres (2,0 - 2000) mg/dm3\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Scieki, w tym wody roztopowe i opadowe Zawiesiny ogolne\nZakres (2,0 - 2000) mg/dm3\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":36,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, including snowmelt and rainwater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 - 2000) mg/dm3"}],"search_zh":"总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法"},{"_id":"6a5dc9aff1c10c8ce825b3dc","lab_id":"69ad52a3de79e566650fb1f1","country":"PL","accr_number":"AB 386","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"2,0 - 12,0"}],"parameters_en":[{"name":"Range","range":"2,0 - 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 2,0 - 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki pH\nZakres 2,0 - 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Scieki pH\nZakres 2,0 - 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":37,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 - 12,0"}],"search_zh":"污水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"污水"},{"_id":"6a5dc9aff1c10c8ce825b3dd","lab_id":"69ad52a3de79e566650fb1f1","country":"PL","accr_number":"AB 386","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie siarczanów","methodology_en":"Sulfate concentration","parameters":[{"name":"Zakres","range":"(10 - 200) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(10 - 200) mg/dm3"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie siarczanów\nZakres (10 - 200) mg/dm3\nMetoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie siarczanów\nZakres (10 - 200) mg/dm3\nMetoda wagowa PN-ISO 9280:2002 Scieki Stezenie siarczanow\nZakres (10 - 200) mg/dm3\nMetoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":38,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Sulfate concentration Gravimetric method Range PN-ISO 9280:2002","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(10 - 200) mg/dm3"}],"search_zh":"污水 硫酸盐浓度 重量法 范围 PN-ISO 9280:2002","technique_zh":"重量法","test_object_zh":"污水"},{"_id":"6a5dc9aff1c10c8ce825b3de","lab_id":"69ad52a3de79e566650fb1f1","country":"PL","accr_number":"AB 386","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie fosforu ogólnego","methodology_en":"Total phosphorus concentration","parameters":[{"name":"Zakres","range":"(0,05 - 200) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,05 - 200) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,05 - 200) mg/dm3\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 pkt 7 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 pkt 7 +Ap1:2010+Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie fosforu ogólnego\nZakres (0,05 - 200) mg/dm3\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt 7 +Ap1:2010+Ap2:2010 Scieki Stezenie fosforu ogolnego\nZakres (0,05 - 200) mg/dm3\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt 7 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":39,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Total phosphorus concentration Spectrophotometric method Range PN-EN ISO 6878:2006 pkt 7 +Ap1:2010+Ap2:2010","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,05 - 200) mg/dm3"}],"search_zh":"污水 总磷浓度 分光光度法 范围 PN-EN ISO 6878:2006 pkt 7 +Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a5dc9aff1c10c8ce825b3df","lab_id":"69ad52a3de79e566650fb1f1","country":"PL","accr_number":"AB 386","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie chlorków","methodology_en":"Chloride concentration","parameters":[{"name":"Zakres","range":"(5 - 2000) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(5 - 2000) mg/dm3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie chlorków\nZakres (5 - 2000) mg/dm3\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie chlorków\nZakres (5 - 2000) mg/dm3\nMetoda miareczkowa PN-ISO 9297:1994 Scieki Stezenie chlorkow\nZakres (5 - 2000) mg/dm3\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":40,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Chloride concentration Titrimetric method Range PN-ISO 9297:1994","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5 - 2000) mg/dm3"}],"search_zh":"污水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"污水"},{"_id":"6a5dc9aff1c10c8ce825b3e0","lab_id":"69ad52a3de79e566650fb1f1","country":"PL","accr_number":"AB 386","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Chemiczne zapotrzebowanie tlenu ChZT-Cr","methodology_en":"Chemical oxygen demand COD-Cr","parameters":[{"name":"Zakres","range":"(4 - 3000) mg/dm3 O2"}],"parameters_en":[{"name":"Range","range":"(4 - 3000) mg/dm3 O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu ChZT-Cr\nZakres (4 - 3000) mg/dm3 O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Chemiczne zapotrzebowanie tlenu ChZT-Cr\nZakres (4 - 3000) mg/dm3 O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Scieki Chemiczne zapotrzebowanie tlenu ChZT-Cr\nZakres (4 - 3000) mg/dm3 O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":41,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Chemical oxygen demand COD-Cr Spectrophotometric method Range PN-ISO 15705:2005","parameters_zh":[{"name":"范围","range":"(4 - 3000) mg/dm3 O2"}],"search_zh":"污水 化学需氧量 COD-Cr 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"污水","methodology_zh":"化学需氧量 COD-Cr"},{"_id":"6a5dc9aff1c10c8ce825b3e1","lab_id":"69ad52a3de79e566650fb1f1","country":"PL","accr_number":"AB 386","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu azotynowego","methodology_en":"Nitrite nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,02 - 3,0) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,02 - 3,0) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu azotynowego\nZakres (0,02 - 3,0) mg/dm3\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu azotynowego\nZakres (0,02 - 3,0) mg/dm3\nMetoda spektrofotometryczna PN-EN 26777:1999 Scieki Stezenie azotu azotynowego\nZakres (0,02 - 3,0) mg/dm3\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":42,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Nitrite nitrogen concentration Spectrophotometric method Range PN-EN 26777:1999","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,02 - 3,0) mg/dm3"}],"search_zh":"污水 亚硝态氮浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a5dc9aff1c10c8ce825b3e2","lab_id":"69ad52a3de79e566650fb1f1","country":"PL","accr_number":"AB 386","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu azotanowego","methodology_en":"Nitrate nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,1 - 15) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,1 - 15) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu azotanowego\nZakres (0,1 - 15) mg/dm3\nMetoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu azotanowego\nZakres (0,1 - 15) mg/dm3\nMetoda spektrofotometryczna PN-82/C-04576/08 Scieki Stezenie azotu azotanowego\nZakres (0,1 - 15) mg/dm3\nMetoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":43,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Nitrate nitrogen concentration Spectrophotometric method Range PN-82/C-04576/08","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,1 - 15) mg/dm3"}],"search_zh":"污水 硝态氮浓度 分光光度法 范围 PN-82/C-04576/08","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a5dc9aff1c10c8ce825b3e3","lab_id":"69ad52a3de79e566650fb1f1","country":"PL","accr_number":"AB 386","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu Kjeldahla","methodology_en":"Kjeldahl nitrogen concentration","parameters":[{"name":"Zakres","range":"(2,0 - 250) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(2,0 - 250) mg/dm3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie azotu Kjeldahla\nZakres (2,0 - 250) mg/dm3\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu Kjeldahla\nZakres (2,0 - 250) mg/dm3\nMetoda miareczkowa PN-EN 25663:2001 Scieki Stezenie azotu Kjeldahla\nZakres (2,0 - 250) mg/dm3\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":44,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Kjeldahl nitrogen concentration Titrimetric method Range PN-EN 25663:2001","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(2,0 - 250) mg/dm3"}],"search_zh":"污水 凯氏氮浓度 滴定法 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"污水"},{"_id":"6a5dc9aff1c10c8ce825b3e4","lab_id":"69ad52a3de79e566650fb1f1","country":"PL","accr_number":"AB 386","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu ogólnego (z obliczeń)","methodology_en":"Total nitrogen concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"Procedura PB-02 Wydanie 2 z dnia 09.11.2017","norm_bases":["Procedura PB-02 Wydanie 2 z dnia 09.11.2017"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu ogólnego (z obliczeń) Procedura PB-02 Wydanie 2 z dnia 09.11.2017 Scieki Stezenie azotu ogolnego (z obliczen) Procedura PB-02 Wydanie 2 z dnia 09.11.2017","categories":["water"],"row_index":45,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Total nitrogen concentration (calculated) Procedura PB-02 Wydanie 2 z dnia 09.11.2017","methodology_zh":"总氮浓度（计算值）","search_zh":"污水 总氮浓度（计算值） Procedura PB-02 Wydanie 2 z dnia 09.11.2017","test_object_zh":"污水"},{"_id":"6a5dc9aff1c10c8ce825b3e5","lab_id":"69ad52a3de79e566650fb1f1","country":"PL","accr_number":"AB 386","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu BZT5, BZT2+5","methodology_en":"Biochemical oxygen demand BOD5, BOD2+5","parameters":[{"name":"Zakres","range":"(1 - 6000) mg/dm3 O2"}],"parameters_en":[{"name":"Range","range":"(1 - 6000) mg/dm3 O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu BZT5, BZT2+5\nZakres (1 - 6000) mg/dm3 O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu BZT5, BZT2+5\nZakres (1 - 6000) mg/dm3 O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Woda, scieki Biochemiczne zapotrzebowanie tlenu BZT5, BZT2+5\nZakres (1 - 6000) mg/dm3 O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":46,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Biochemical oxygen demand BOD5, BOD2+5 Electrochemical method Range PN-EN ISO 5815-1:2019-12","parameters_zh":[{"name":"范围","range":"(1 - 6000) mg/dm3 O2"}],"search_zh":"水、废水 电化学法 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"水、废水"},{"_id":"6a5dc9aff1c10c8ce825b3e6","lab_id":"69ad52a3de79e566650fb1f1","country":"PL","accr_number":"AB 386","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Chemiczne zapotrzebowanie tlenu ChZT-Cr","methodology_en":"Chemical oxygen demand COD-Cr","parameters":[{"name":"Zakres","range":"(4 - 40) mg/dm3 O2"}],"parameters_en":[{"name":"Range","range":"(4 - 40) mg/dm3 O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu ChZT-Cr\nZakres (4 - 40) mg/dm3 O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Chemiczne zapotrzebowanie tlenu ChZT-Cr\nZakres (4 - 40) mg/dm3 O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda Chemiczne zapotrzebowanie tlenu ChZT-Cr\nZakres (4 - 40) mg/dm3 O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":47,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Chemical oxygen demand COD-Cr Spectrophotometric method Range PN-ISO 15705:2005","parameters_zh":[{"name":"范围","range":"(4 - 40) mg/dm3 O2"}],"search_zh":"水 化学需氧量 COD-Cr 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水","methodology_zh":"化学需氧量 COD-Cr"},{"_id":"6a5dc9aff1c10c8ce825b3e7","lab_id":"69ad52a3de79e566650fb1f1","country":"PL","accr_number":"AB 386","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie cyjanków ogólnych","methodology_en":"Total cyanide concentration","parameters":[{"name":"Zakres","range":"(2,0 – 200) μg/dm3"}],"parameters_en":[{"name":"Range","range":"(2,0 – 200) μg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie cyjanków ogólnych\nZakres (2,0 – 200) μg/dm3\nMetoda spektrofotometryczna","reference":"Procedura PB-01 Wydanie 1 z dnia 08.01.2025 | na podstawie testu Merck nr 1.09701.0001","norm_bases":["Procedura PB-01 Wydanie 1 z dnia 08.01.2025","na podstawie testu Merck nr 1.09701.0001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie cyjanków ogólnych\nZakres (2,0 – 200) μg/dm3\nMetoda spektrofotometryczna Procedura PB-01 Wydanie 1 z dnia 08.01.2025 | na podstawie testu Merck nr 1.09701.0001 Woda Stezenie cyjankow ogolnych\nZakres (2,0 – 200) μg/dm3\nMetoda spektrofotometryczna Procedura PB-01 Wydanie 1 z dnia 08.01.2025 | na podstawie testu Merck nr 1.09701.0001","categories":["water"],"row_index":48,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Total cyanide concentration Spectrophotometric method Range Procedura PB-01 Wydanie 1 z dnia 08.01.2025 | na podstawie testu Merck nr 1.09701.0001","parameters_zh":[{"name":"范围","range":"(2,0 – 200) μg/dm3"}],"search_zh":"水 总氰化物浓度 分光光度法 范围 Procedura PB-01 Wydanie 1 z dnia 08.01.2025 | na podstawie testu Merck nr 1.09701.0001","technique_zh":"分光光度法","test_object_zh":"水","methodology_zh":"总氰化物浓度"}],"has_pdf":true}