{"lab":{"_id":"69ad52a3de79e566650fb1ed","accr_number":"AB 381","country":"PL","accr_body":"PCA","address":"ul. Oszczepników 4, 02-633 Warszawa, LABORATORIUM BADAWCZE, Helenów 6A","categories":["food","water","microbiology","environment","metrology","petro"],"city":"Warszawa","imported_at":"2026-03-08T10:42:43.265Z","methods_count":146,"name":"INTERTEK POLAND Sp. z o.o.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_381.pdf"],"scope_summary":"","search_text":"intertek poland sp. z o.o. ul. oszczepników 4, 02-633 warszawa, laboratorium badawcze, helenów 6a other food microbiology environment water automotive materials metrology pharma electronics","status":"active","updated_at":"2026-03-08T14:51:12.910Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-17T20:07:48.599Z","location":{"type":"Point","coordinates":[21.0122,52.2297]},"email_confidence":"high","email_mx":true,"email_source":"https://www.pca.gov.pl/akredytowane-podmioty/akredytacje-aktywne/laboratoria-badawcze/AB%20381,podmiot.html","fields_of_testing":[{"codes":"B/22, B/55; B/57","pl":"Badania biologiczne i biochemiczne żywności, pasz dla zwierząt, obiektów z obszaru produkcji żywności","en":"Biological and biochemical tests of food, animal feedstuffs"},{"codes":"C/1; C/22; C/55","pl":"Badania chemiczne produktów rolnych, żywności, pasz dla zwierząt","en":"Chemical tests of agricultural products, food, animal feedstuffs"},{"codes":"C/28","pl":"Badania chemiczne wody","en":"Chemical tests of water"},{"codes":"C/29/P","pl":"Badania chemiczne i pobieranie próbek wody do spożycia przez ludzi","en":"Chemical tests and sampling of drinking water"},{"codes":"K/22; K/55; K/57","pl":"Badania mikrobiologiczne żywności, pasz dla zwierząt, obiektów z obszaru produkcji żywności","en":"Microbiological tests of food, animal feedstuffs, objects from food production area"},{"codes":"K/3/P; K/9/P; K/28/P; K/29/P; K/57/P","pl":"Badania mikrobiologiczne i pobieranie próbek obiektów i materiałów biologicznych przeznaczonych do badań, powietrza, wody, wody do spożycia przez ludzi, obiektów z obszaru produkcji żywności","en":"Microbiological tests and sampling of biological items and materials for testing, air, drinking water, water, objects from food production area"},{"codes":"N/1; N/22; N/55","pl":"Badania właściwości fizycznych produktów rolnych, żywności, pasz dla zwierząt","en":"Tests of physical properties of agricultural products, food, animal feedstuffs"},{"codes":"N/28","pl":"Badania własności fizycznych wody","en":"Tests of physical properties of water"},{"codes":"N/29/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody do spożycia przez ludzi","en":"Chemical tests and sampling of drinking water"},{"codes":"Q/22; Q/29","pl":"Badania sensoryczne żywności, wody do spożycia przez ludzi","en":"Sensory tests of food, drinking water"}],"issue":{"no":"29","date":"10.06.2026"},"parse_date":"2026-08-17T20:07:48.599Z","parse_source":"agent-claude-code","map_coord":[52.197028,20.996873],"map_geo":"nominatim-street","lab_locations":[{"name":"LABORATORIUM BADAWCZE","address":"AB 381 09-500 Gostynin","city":"Gostynin","postal":"09-500"},{"name":"Pracownia Analiz Mikrobiologicznych","address":"Helenów 6A, 09-500 Gostynin","city":"Gostynin","postal":"09-500"},{"name":"Pracownia Analiz Chemicznych","address":"Helenów 6A, 09-500 Gostynin","city":"Gostynin","postal":"09-500"},{"name":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","address":null,"city":null,"postal":null},{"name":"Pracownia Analiz Mikrobiologicznych; Helenów 6A, 09-500 Gostynin","address":null,"city":null,"postal":null}],"scope_format":"PCA::pracownie+elastyczny+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/36799aae3a7180c072a68f42755ad130/AB%20381.pdf","has_en":true,"category_counts":{"food":87,"other":32,"water":23,"microbiology":21,"environment":16,"metrology":11,"petro":10,"materials":1},"category_scores":{"food":37.66,"other":5.09,"water":2.63,"microbiology":2.19,"environment":1.27,"metrology":0.6,"petro":0.5,"materials":0},"has_zh":true,"lab_locations_zh":[{"name":"检测实验室","address":"AB 381 09-500 Gostynin","city":"Gostynin","postal":"09-500"},{"name":"Pracownia Analiz Mikrobiologicznych","address":"Helenów 6A, 09-500 Gostynin","city":"Gostynin","postal":"09-500"},{"name":"Pracownia Analiz Chemicznych","address":"Helenów 6A, 09-500 Gostynin","city":"Gostynin","postal":"09-500"},{"name":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","address":null,"city":null,"postal":null},{"name":"Pracownia Analiz Mikrobiologicznych; Helenów 6A, 09-500 Gostynin","address":null,"city":null,"postal":null}]},"methods":[{"_id":"6a836a14af14b9c0e7b1de93","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Produkty żywnościowe i pasze","methodology":"Liczba przypuszczalnych Escherichia coli","parameters":[],"technique":"Metoda hodowlana z potwierdzeniami biochemicznymi","techniques":["Metoda hodowlana z potwierdzeniami biochemicznymi"],"computed":[],"activity":"Liczba przypuszczalnych Escherichia coli\nMetoda hodowlana z potwierdzeniami biochemicznymi","reference":"PN-ISO 7251:2006","norm_bases":["PN-ISO 7251:2006"],"lab_section":"Pracownia Analiz Mikrobiologicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Produkty żywnościowe i pasze Liczba przypuszczalnych Escherichia coli\nMetoda hodowlana z potwierdzeniami biochemicznymi PN-ISO 7251:2006 Produkty zywnosciowe i pasze Liczba przypuszczalnych Escherichia coli\nMetoda hodowlana z potwierdzeniami biochemicznymi PN-ISO 7251:2006","categories":["food","microbiology"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Foods and feed Culture method with biochemical confirmations PN-ISO 7251:2006","technique_en":"Culture method with biochemical confirmations","test_object_en":"Foods and feed"},{"_id":"6a836a14af14b9c0e7b1de94","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Próbki środowiskowe z obszarów produkcji i obrotu żywnością - wymaz z powierzchni ograniczonej szablonem, - wymaz z powierzchni nieograniczonej szablonem, w tym z rąk, - odcisk z powierzchni","methodology":"Pobieranie próbek z powierzchni do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek z powierzchni do badań mikrobiologicznych","reference":"PN-ISO 18593:2018-08","norm_bases":["PN-ISO 18593:2018-08"],"lab_section":"Pracownia Analiz Mikrobiologicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Próbki środowiskowe z obszarów produkcji i obrotu żywnością - wymaz z powierzchni ograniczonej szablonem, - wymaz z powierzchni nieograniczonej szablonem, w tym z rąk, - odcisk z powierzchni Pobieranie próbek z powierzchni do badań mikrobiologicznych PN-ISO 18593:2018-08 Probki srodowiskowe z obszarow produkcji i obrotu zywnoscia - wymaz z powierzchni ograniczonej szablonem, - wymaz z powierzchni nieograniczonej szablonem, w tym z rak, - odcisk z powierzchni Pobieranie probek z powierzchni do badan mikrobiologicznych PN-ISO 18593:2018-08","categories":["food","environment","microbiology"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Surface sampling for microbiological testing","search_en":"Environmental samples from food production and distribution areas - swab from an area delimited by a template, - swab from an area not delimited by a template, including from hands, - surface imprint Surface sampling for microbiological testing PN-ISO 18593:2018-08","test_object_en":"Environmental samples from food production and distribution areas - swab from an area delimited by a template, - swab from an area not delimited by a template, including from hands, - surface imprint","methodology_zh":"微生物检测用表面样品采集","search_zh":"微生物检测用表面样品采集 PN-ISO 18593:2018-08"},{"_id":"6a836a14af14b9c0e7b1de95","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Kał zwierząt","methodology":"Obecność pałeczek Salmonella spp.","parameters":[],"technique":"Metoda hodowlana z potwierdzeniami biochemicznymi i serologicznymi","techniques":["Metoda hodowlana z potwierdzeniami biochemicznymi i serologicznymi"],"computed":[],"activity":"Obecność pałeczek Salmonella spp.\nMetoda hodowlana z potwierdzeniami biochemicznymi i serologicznymi","reference":"PN-EN ISO 6579-1:2017-04+A1:2020-09","norm_bases":["PN-EN ISO 6579-1:2017-04+A1:2020-09"],"lab_section":"Pracownia Analiz Mikrobiologicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kał zwierząt Obecność pałeczek Salmonella spp.\nMetoda hodowlana z potwierdzeniami biochemicznymi i serologicznymi PN-EN ISO 6579-1:2017-04+A1:2020-09 Kal zwierzat Obecnosc paleczek Salmonella spp.\nMetoda hodowlana z potwierdzeniami biochemicznymi i serologicznymi PN-EN ISO 6579-1:2017-04+A1:2020-09","categories":["microbiology"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of Salmonella spp. rods","search_en":"Animal faeces Presence of Salmonella spp. rods Culture method with biochemical and serological confirmations PN-EN ISO 6579-1:2017-04+A1:2020-09","technique_en":"Culture method with biochemical and serological confirmations","test_object_en":"Animal faeces","methodology_zh":"沙门氏菌属（Salmonella spp.）的检出","search_zh":"沙门氏菌属（Salmonella spp.）的检出 培养法（附生化与血清学确证） PN-EN ISO 6579-1:2017-04+A1:2020-09","technique_zh":"培养法（附生化与血清学确证）"},{"_id":"6a836a14af14b9c0e7b1de96","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do analiz mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do analiz mikrobiologicznych","reference":"PN EN ISO 19458:2007","norm_bases":["PN EN ISO 19458:2007"],"lab_section":"Pracownia Analiz Mikrobiologicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do analiz mikrobiologicznych PN EN ISO 19458:2007 Woda do spozycia przez ludzi Pobieranie probek do analiz mikrobiologicznych PN EN ISO 19458:2007","categories":["water","microbiology"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for microbiological analyses","search_en":"Water intended for human consumption Sampling for microbiological analyses PN EN ISO 19458:2007","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 用于微生物分析的采样 PN EN ISO 19458:2007","test_object_zh":"生活饮用水","methodology_zh":"用于微生物分析的采样"},{"_id":"6a836a14af14b9c0e7b1de97","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Tusze zwierząt rzeźnych: - wycinki - wymaz","methodology":"Pobieranie próbek z tusz do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek z tusz do badań mikrobiologicznych","reference":"PN-EN ISO 17604:2015-10","norm_bases":["PN-EN ISO 17604:2015-10"],"lab_section":"Pracownia Analiz Mikrobiologicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Tusze zwierząt rzeźnych: - wycinki - wymaz Pobieranie próbek z tusz do badań mikrobiologicznych PN-EN ISO 17604:2015-10 Tusze zwierzat rzeznych: - wycinki - wymaz Pobieranie probek z tusz do badan mikrobiologicznych PN-EN ISO 17604:2015-10","categories":["microbiology"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling from carcasses for microbiological testing","search_en":"Carcasses of slaughter animals: - excised samples - swab Sampling from carcasses for microbiological testing PN-EN ISO 17604:2015-10","test_object_en":"Carcasses of slaughter animals: - excised samples - swab","methodology_zh":"用于微生物检验的胴体采样","search_zh":"用于微生物检验的胴体采样 PN-EN ISO 17604:2015-10"},{"_id":"6a836a14af14b9c0e7b1de98","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Tkanka mięśniowa","methodology":"Obecność pozostałości antybiotyków i innych substancji hamujących","parameters":[],"technique":"Metoda mikrobiologiczna skriningowa (Premi®Test)","techniques":["Metoda mikrobiologiczna skriningowa (Premi®Test)"],"computed":[],"activity":"Obecność pozostałości antybiotyków i innych substancji hamujących\nMetoda mikrobiologiczna skriningowa (Premi®Test)","reference":"PB/PAM/28 Wydanie 1 z dnia 25.01.2017 | na podstawie testu r-biofarm Nr R3925","norm_bases":["PB/PAM/28 Wydanie 1 z dnia 25.01.2017","na podstawie testu r-biofarm Nr R3925"],"lab_section":"Pracownia Analiz Mikrobiologicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Tkanka mięśniowa Obecność pozostałości antybiotyków i innych substancji hamujących\nMetoda mikrobiologiczna skriningowa (Premi®Test) PB/PAM/28 Wydanie 1 z dnia 25.01.2017 | na podstawie testu r-biofarm Nr R3925 Tkanka miesniowa Obecnosc pozostalosci antybiotykow i innych substancji hamujacych\nMetoda mikrobiologiczna skriningowa (Premi®Test) PB/PAM/28 Wydanie 1 z dnia 25.01.2017 | na podstawie testu r-biofarm Nr R3925","categories":["microbiology"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of antibiotic residues and other inhibitory substances","search_en":"Muscle tissue Presence of antibiotic residues and other inhibitory substances PB/PAM/28 Wydanie 1 z dnia 25.01.2017 | na podstawie testu r-biofarm Nr R3925","test_object_en":"Muscle tissue"},{"_id":"6a836a14af14b9c0e7b1de99","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Powietrze","methodology":"Pobieranie próbek powietrza do analiz mikrobiologicznych","parameters":[],"technique":"metoda zderzeniowa","techniques":["metoda zderzeniowa"],"computed":[],"activity":"Pobieranie próbek powietrza do analiz mikrobiologicznych\nmetoda zderzeniowa","reference":"PB/PAM/30 wydanie 1 z dnia 29.11.2019","norm_bases":["PB/PAM/30 wydanie 1 z dnia 29.11.2019"],"lab_section":"Pracownia Analiz Mikrobiologicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Powietrze Pobieranie próbek powietrza do analiz mikrobiologicznych\nmetoda zderzeniowa PB/PAM/30 wydanie 1 z dnia 29.11.2019 Powietrze Pobieranie probek powietrza do analiz mikrobiologicznych\nmetoda zderzeniowa PB/PAM/30 wydanie 1 z dnia 29.11.2019","categories":["environment","microbiology"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air sampling for microbiological analyses","search_en":"Air Air sampling for microbiological analyses PB/PAM/30 wydanie 1 z dnia 29.11.2019","test_object_en":"Air","search_zh":"空气 PB/PAM/30 wydanie 1 z dnia 29.11.2019","test_object_zh":"空气"},{"_id":"6a836a14af14b9c0e7b1de9a","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Powietrze","methodology":"Ogólna liczba pleśni","parameters":[],"technique":"Metoda płytkowa","techniques":["Metoda płytkowa"],"computed":[],"activity":"Ogólna liczba pleśni\nMetoda płytkowa","reference":"PB/PAM/30 wydanie 1 z dnia 29.11.2019","norm_bases":["PB/PAM/30 wydanie 1 z dnia 29.11.2019"],"lab_section":"Pracownia Analiz Mikrobiologicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Powietrze Ogólna liczba pleśni\nMetoda płytkowa PB/PAM/30 wydanie 1 z dnia 29.11.2019 Powietrze Ogolna liczba plesni\nMetoda plytkowa PB/PAM/30 wydanie 1 z dnia 29.11.2019","categories":["environment"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total mould count","search_en":"Air Total mould count Plate method PB/PAM/30 wydanie 1 z dnia 29.11.2019","technique_en":"Plate method","test_object_en":"Air","search_zh":"空气 平板法 PB/PAM/30 wydanie 1 z dnia 29.11.2019","technique_zh":"平板法","test_object_zh":"空气"},{"_id":"6a836a14af14b9c0e7b1de9b","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Powietrze","methodology":"Ogólna liczba drożdży","parameters":[],"technique":"Metoda płytkowa","techniques":["Metoda płytkowa"],"computed":[],"activity":"Ogólna liczba drożdży\nMetoda płytkowa","reference":"PB/PAM/30 wydanie 1 z dnia 29.11.2019","norm_bases":["PB/PAM/30 wydanie 1 z dnia 29.11.2019"],"lab_section":"Pracownia Analiz Mikrobiologicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Powietrze Ogólna liczba drożdży\nMetoda płytkowa PB/PAM/30 wydanie 1 z dnia 29.11.2019 Powietrze Ogolna liczba drozdzy\nMetoda plytkowa PB/PAM/30 wydanie 1 z dnia 29.11.2019","categories":["environment"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total yeast count","search_en":"Air Total yeast count Plate method PB/PAM/30 wydanie 1 z dnia 29.11.2019","technique_en":"Plate method","test_object_en":"Air","search_zh":"空气 平板法 PB/PAM/30 wydanie 1 z dnia 29.11.2019","technique_zh":"平板法","test_object_zh":"空气"},{"_id":"6a836a14af14b9c0e7b1de9c","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Powietrze","methodology":"Ogólna liczba bakterii","parameters":[],"technique":"Metoda płytkowa","techniques":["Metoda płytkowa"],"computed":[],"activity":"Ogólna liczba bakterii\nMetoda płytkowa","reference":"PB/PAM/30 wydanie 1 z dnia 29.11.2019","norm_bases":["PB/PAM/30 wydanie 1 z dnia 29.11.2019"],"lab_section":"Pracownia Analiz Mikrobiologicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Powietrze Ogólna liczba bakterii\nMetoda płytkowa PB/PAM/30 wydanie 1 z dnia 29.11.2019 Powietrze Ogolna liczba bakterii\nMetoda plytkowa PB/PAM/30 wydanie 1 z dnia 29.11.2019","categories":["environment","microbiology"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total bacterial count","search_en":"Air Total bacterial count Plate method PB/PAM/30 wydanie 1 z dnia 29.11.2019","technique_en":"Plate method","test_object_en":"Air","search_zh":"空气 细菌总数 平板法 PB/PAM/30 wydanie 1 z dnia 29.11.2019","technique_zh":"平板法","test_object_zh":"空气","methodology_zh":"细菌总数"},{"_id":"6a836a14af14b9c0e7b1de9d","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Żywność E, Pasze, Próbki środowiskowe E, Woda do spożycia przez ludzi","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny)","reference":"Normy, procedury badawcze","norm_bases":["Normy, procedury badawcze"],"lab_section":"Pracownia Analiz Mikrobiologicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze, Próbki środowiskowe E, Woda do spożycia przez ludzi Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny) Normy, procedury badawcze Zywnosc E, Pasze, Probki srodowiskowe E, Woda do spozycia przez ludzi Liczba drobnoustrojow\nMetoda plytkowa (posiew wglebny) Normy, procedury badawcze","categories":["food","water","environment","microbiology"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Microorganism count","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Microorganism count Plate method (pour plate) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy, procedury badawcze","technique_en":"Plate method (pour plate)","methodology_zh":"菌落总数","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"菌落总数 平板法（倾注培养） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy, procedury badawcze","technique_zh":"平板法（倾注培养）"},{"_id":"6a836a14af14b9c0e7b1de9e","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Żywność E, Pasze, Próbki środowiskowe E","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda płytkowa (posiew powierzchniowy)"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda płytkowa (posiew powierzchniowy)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Pracownia Analiz Mikrobiologicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze, Próbki środowiskowe E Liczba drobnoustrojów\nMetoda płytkowa (posiew powierzchniowy) Normy Zywnosc E, Pasze, Probki srodowiskowe E Liczba drobnoustrojow\nMetoda plytkowa (posiew powierzchniowy) Normy","categories":["food","environment","microbiology"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Microorganism count","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Microorganism count Plate method (spread plate) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy","technique_en":"Plate method (spread plate)","methodology_zh":"菌落总数","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"菌落总数 平板法（表面涂布） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy","technique_zh":"平板法（表面涂布）"},{"_id":"6a836a14af14b9c0e7b1de9f","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Żywność E, Pasze, Próbki środowiskowe E","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym","reference":"Normy","norm_bases":["Normy"],"lab_section":"Pracownia Analiz Mikrobiologicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze, Próbki środowiskowe E Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym Normy Zywnosc E, Pasze, Probki srodowiskowe E Obecnosc drobnoustrojow\nMetoda hodowlana z potwierdzeniem biochemicznym Normy","categories":["food","environment","microbiology"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of microorganisms","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Presence of microorganisms Culture method with biochemical confirmation E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy","technique_en":"Culture method with biochemical confirmation","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"微生物的检出 培养法结合生化确认 E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy","technique_zh":"培养法结合生化确认","methodology_zh":"微生物的检出"},{"_id":"6a836a14af14b9c0e7b1dea0","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Żywność E, Pasze, Próbki środowiskowe E","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"Normy","norm_bases":["Normy"],"lab_section":"Pracownia Analiz Mikrobiologicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze, Próbki środowiskowe E Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym Normy Zywnosc E, Pasze, Probki srodowiskowe E Obecnosc drobnoustrojow\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym Normy","categories":["food","environment","microbiology"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of microorganisms","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Presence of microorganisms Culture method with biochemical and serological confirmation E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy","technique_en":"Culture method with biochemical and serological confirmation","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"微生物的检出 培养法结合生化与血清学确认 E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy","technique_zh":"培养法结合生化与血清学确认","methodology_zh":"微生物的检出"},{"_id":"6a836a14af14b9c0e7b1dea1","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Żywność E, Próbki środowiskowe E","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i mikroskopowym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i mikroskopowym"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym i mikroskopowym","reference":"Normy","norm_bases":["Normy"],"lab_section":"Pracownia Analiz Mikrobiologicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Próbki środowiskowe E Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym i mikroskopowym Normy Zywnosc E, Probki srodowiskowe E Obecnosc drobnoustrojow\nMetoda hodowlana z potwierdzeniem biochemicznym i mikroskopowym Normy","categories":["food","environment","microbiology"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of microorganisms","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Presence of microorganisms Culture method with biochemical and microscopic confirmation E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy","technique_en":"Culture method with biochemical and microscopic confirmation","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"微生物的检出 培养法（附生化与显微确证） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy","methodology_zh":"微生物的检出","technique_zh":"培养法（附生化与显微确证）"},{"_id":"6a836a14af14b9c0e7b1dea2","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Żywność E","methodology":"Obecność werotoksycznych Escherichia coli (STEC) oraz serotypowanie O157, O111, O26, O103, O145","parameters":[],"technique":"Metoda real-time PCR","techniques":["Metoda real-time PCR"],"computed":[],"activity":"Obecność werotoksycznych Escherichia coli (STEC) oraz serotypowanie O157, O111, O26, O103, O145\nMetoda real-time PCR","reference":"Normy","norm_bases":["Normy"],"lab_section":"Pracownia Analiz Mikrobiologicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Obecność werotoksycznych Escherichia coli (STEC) oraz serotypowanie O157, O111, O26, O103, O145\nMetoda real-time PCR Normy Zywnosc E Obecnosc werotoksycznych Escherichia coli (STEC) oraz serotypowanie O157, O111, O26, O103, O145\nMetoda real-time PCR Normy","categories":["food","microbiology"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Food E Real-time PCR method E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy","technique_en":"Real-time PCR method","test_object_en":"Food E","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"食品 E 实时荧光 PCR 法 E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy","test_object_zh":"食品 E","technique_zh":"实时荧光 PCR 法"},{"_id":"6a836a14af14b9c0e7b1dea3","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Żywność E","methodology":"Obecność werotoksycznych Escherichia coli (STEC) oraz serotypowanie O104, O45, O121","parameters":[],"technique":"Metoda real-time PCR","techniques":["Metoda real-time PCR"],"computed":[],"activity":"Obecność werotoksycznych Escherichia coli (STEC) oraz serotypowanie O104, O45, O121\nMetoda real-time PCR","reference":"Normy | Instrukcja Producenta","norm_bases":["Normy","Instrukcja Producenta"],"lab_section":"Pracownia Analiz Mikrobiologicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Obecność werotoksycznych Escherichia coli (STEC) oraz serotypowanie O104, O45, O121\nMetoda real-time PCR Normy | Instrukcja Producenta Zywnosc E Obecnosc werotoksycznych Escherichia coli (STEC) oraz serotypowanie O104, O45, O121\nMetoda real-time PCR Normy | Instrukcja Producenta","categories":["food","microbiology"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Food E Real-time PCR method E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy | Instrukcja Producenta","technique_en":"Real-time PCR method","test_object_en":"Food E","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"食品 E 实时荧光 PCR 法 E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy | Instrukcja Producenta","test_object_zh":"食品 E","technique_zh":"实时荧光 PCR 法"},{"_id":"6a836a14af14b9c0e7b1dea4","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Woda powierzchniowa, Woda do spożycia przez ludzi, Woda użytkowa ciepła i zimna, Woda chłodnicza, Woda mineralna, Woda źródlana, Woda stołowa, Żywność E","methodology":"Liczba drobnoustrojów w określonej objętości próbki","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba drobnoustrojów w określonej objętości próbki\nMetoda filtracji membranowej","reference":"Normy","norm_bases":["Normy"],"lab_section":"Pracownia Analiz Mikrobiologicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Woda powierzchniowa, Woda do spożycia przez ludzi, Woda użytkowa ciepła i zimna, Woda chłodnicza, Woda mineralna, Woda źródlana, Woda stołowa, Żywność E Liczba drobnoustrojów w określonej objętości próbki\nMetoda filtracji membranowej Normy Woda powierzchniowa, Woda do spozycia przez ludzi, Woda uzytkowa ciepla i zimna, Woda chlodnicza, Woda mineralna, Woda zrodlana, Woda stolowa, Zywnosc E Liczba drobnoustrojow w okreslonej objetosci probki\nMetoda filtracji membranowej Normy","categories":["water","food","microbiology"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Membrane filtration method E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy","technique_en":"Membrane filtration method","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"膜过滤法 E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy","technique_zh":"膜过滤法"},{"_id":"6a836a14af14b9c0e7b1dea5","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Żywność E, Pasze, Próbki środowiskowe E","methodology":"Obecność specyficznego DNA wykrywanego drobnoustroju","parameters":[],"technique":"Metoda PCR, system Bax","techniques":["Metoda PCR, system Bax"],"computed":[],"activity":"Obecność specyficznego DNA wykrywanego drobnoustroju\nMetoda PCR, system Bax","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Analiz Mikrobiologicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze, Próbki środowiskowe E Obecność specyficznego DNA wykrywanego drobnoustroju\nMetoda PCR, system Bax Procedury badawcze Zywnosc E, Pasze, Probki srodowiskowe E Obecnosc specyficznego DNA wykrywanego drobnoustroju\nMetoda PCR, system Bax Procedury badawcze","categories":["food","environment","microbiology"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"PCR method, Bax system E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Procedury badawcze","technique_en":"PCR method, Bax system","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Procedury badawcze"},{"_id":"6a836a14af14b9c0e7b1dea6","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Żywność E, Pasze, Próbki środowiskowe E","methodology":"Obecność drobnoustroju","parameters":[],"technique":"Metoda immunoenzymatyczna(ELISA)","techniques":["Metoda immunoenzymatyczna(ELISA)"],"computed":[],"activity":"Obecność drobnoustroju\nMetoda immunoenzymatyczna(ELISA)","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Analiz Mikrobiologicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze, Próbki środowiskowe E Obecność drobnoustroju\nMetoda immunoenzymatyczna(ELISA) Procedury badawcze Zywnosc E, Pasze, Probki srodowiskowe E Obecnosc drobnoustroju\nMetoda immunoenzymatyczna(ELISA) Procedury badawcze","categories":["food","environment","microbiology"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Enzyme immunoassay method (ELISA) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Procedury badawcze","technique_en":"Enzyme immunoassay method (ELISA)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Procedury badawcze"},{"_id":"6a836a14af14b9c0e7b1dea7","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Żywność w opakowaniach hermetycznych E","methodology":"Trwałość","parameters":[],"technique":"Metoda próby termostatowej","techniques":["Metoda próby termostatowej"],"computed":[],"activity":"Trwałość\nMetoda próby termostatowej","reference":"Normy","norm_bases":["Normy"],"lab_section":"Pracownia Analiz Mikrobiologicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność w opakowaniach hermetycznych E Trwałość\nMetoda próby termostatowej Normy Zywnosc w opakowaniach hermetycznych E Trwalosc\nMetoda proby termostatowej Normy","categories":["food"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Durability","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Durability Thermostatic test method E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy","technique_en":"Thermostatic test method","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"耐久性 恒温试验法 E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy","methodology_zh":"耐久性","technique_zh":"恒温试验法"},{"_id":"6a836a14af14b9c0e7b1dea8","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Żywność E, Próbki środowiskowe E, Powierzchnie tusz zwierząt rzeźnych, Próbki z produkcji pierwotnej","methodology":"Obecność DNA wykrywanego drobnoustroju","parameters":[],"technique":"Metoda LAMP, system MDS (izotermiczna reakcja łańcuchowej polimerazy isoPCR)","techniques":["Metoda LAMP, system MDS (izotermiczna reakcja łańcuchowej polimerazy isoPCR)"],"computed":[],"activity":"Obecność DNA wykrywanego drobnoustroju\nMetoda LAMP, system MDS (izotermiczna reakcja łańcuchowej polimerazy isoPCR)","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Analiz Mikrobiologicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Próbki środowiskowe E, Powierzchnie tusz zwierząt rzeźnych, Próbki z produkcji pierwotnej Obecność DNA wykrywanego drobnoustroju\nMetoda LAMP, system MDS (izotermiczna reakcja łańcuchowej polimerazy isoPCR) Procedury badawcze Zywnosc E, Probki srodowiskowe E, Powierzchnie tusz zwierzat rzeznych, Probki z produkcji pierwotnej Obecnosc DNA wykrywanego drobnoustroju\nMetoda LAMP, system MDS (izotermiczna reakcja lancuchowej polimerazy isoPCR) Procedury badawcze","categories":["food","materials","environment","microbiology"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Procedury badawcze","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Procedury badawcze"},{"_id":"6a836a14af14b9c0e7b1dea9","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Żywność E, Próbki środowiskowe E, Powierzchnie tusz zwierząt rzeźnych, Pasze","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda Petrifilm","techniques":["Metoda Petrifilm"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda Petrifilm","reference":"Instrukcje producenta testu NEOGEN Petrifilm","norm_bases":["Instrukcje producenta testu NEOGEN Petrifilm"],"lab_section":"Pracownia Analiz Mikrobiologicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Próbki środowiskowe E, Powierzchnie tusz zwierząt rzeźnych, Pasze Liczba drobnoustrojów\nMetoda Petrifilm Instrukcje producenta testu NEOGEN Petrifilm Zywnosc E, Probki srodowiskowe E, Powierzchnie tusz zwierzat rzeznych, Pasze Liczba drobnoustrojow\nMetoda Petrifilm Instrukcje producenta testu NEOGEN Petrifilm","categories":["food","environment","microbiology"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Microorganism count","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Microorganism count Petrifilm method E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Instrukcje producenta testu NEOGEN Petrifilm","technique_en":"Petrifilm method","methodology_zh":"菌落总数","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"菌落总数 Petrifilm 测试片法 E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Instrukcje producenta testu NEOGEN Petrifilm","technique_zh":"Petrifilm 测试片法"},{"_id":"6a836a14af14b9c0e7b1deaa","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Mięso i przetwory mięsne","methodology":"Zawartość soli kuchennej","parameters":[{"name":"Zakres","range":"(0,05 − 9,0) %"}],"technique":"Metoda miareczkowa (Mohra)","techniques":["Metoda miareczkowa (Mohra)"],"computed":[],"activity":"Zawartość soli kuchennej\nZakres (0,05 − 9,0) %\nMetoda miareczkowa (Mohra)","reference":"PN-73/A-82112+Az1:2002","norm_bases":["PN-73/A-82112+Az1:2002"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i przetwory mięsne Zawartość soli kuchennej\nZakres (0,05 − 9,0) %\nMetoda miareczkowa (Mohra) PN-73/A-82112+Az1:2002 Mieso i przetwory miesne Zawartosc soli kuchennej\nZakres (0,05 − 9,0) %\nMetoda miareczkowa (Mohra) PN-73/A-82112+Az1:2002","categories":["food"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Table salt content","parameters_en":[{"name":"Range","range":"(0,05 − 9,0) %"}],"search_en":"Meat and meat products Table salt content Titrimetric method (Mohr) Range PN-73/A-82112+Az1:2002","technique_en":"Titrimetric method (Mohr)","test_object_en":"Meat and meat products","parameters_zh":[{"name":"范围","range":"(0,05 − 9,0) %"}],"search_zh":"肉与肉制品 食盐含量 滴定法（莫尔法） 范围 PN-73/A-82112+Az1:2002","test_object_zh":"肉与肉制品","methodology_zh":"食盐含量","technique_zh":"滴定法（莫尔法）"},{"_id":"6a836a14af14b9c0e7b1deab","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Mięso i przetwory mięsne","methodology":"Zawartość tłuszczu","parameters":[{"name":"Zakres","range":"(0,5 – 90) %"}],"technique":"Metoda butyrometryczna (Gerbera)","techniques":["Metoda butyrometryczna (Gerbera)"],"computed":[],"activity":"Zawartość tłuszczu\nZakres (0,5 – 90) %\nMetoda butyrometryczna (Gerbera)","reference":"PN-85/A-82100 pkt 2.3.1","norm_bases":["PN-85/A-82100 pkt 2.3.1"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i przetwory mięsne Zawartość tłuszczu\nZakres (0,5 – 90) %\nMetoda butyrometryczna (Gerbera) PN-85/A-82100 pkt 2.3.1 Mieso i przetwory miesne Zawartosc tluszczu\nZakres (0,5 – 90) %\nMetoda butyrometryczna (Gerbera) PN-85/A-82100 pkt 2.3.1","categories":["food"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fat content","parameters_en":[{"name":"Range","range":"(0,5 – 90) %"}],"search_en":"Meat and meat products Fat content Butyrometric method (Gerber) Range PN-85/A-82100 pkt 2.3.1","technique_en":"Butyrometric method (Gerber)","test_object_en":"Meat and meat products","methodology_zh":"脂肪含量","parameters_zh":[{"name":"范围","range":"(0,5 – 90) %"}],"search_zh":"肉与肉制品 脂肪含量 范围 PN-85/A-82100 pkt 2.3.1","test_object_zh":"肉与肉制品"},{"_id":"6a836a14af14b9c0e7b1deac","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Mięso i przetwory mięsne","methodology":"Zawartość fosforu całkowitego w przeliczeniu na P2O5","parameters":[{"name":"Zakres","range":"(1,000 – 15) g/kg"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość fosforu całkowitego w przeliczeniu na P2O5\nZakres (1,000 – 15) g/kg\nMetoda spektrofotometryczna","reference":"PN-ISO 13730:1999+Ap1:2004","norm_bases":["PN-ISO 13730:1999+Ap1:2004"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i przetwory mięsne Zawartość fosforu całkowitego w przeliczeniu na P2O5\nZakres (1,000 – 15) g/kg\nMetoda spektrofotometryczna PN-ISO 13730:1999+Ap1:2004 Mieso i przetwory miesne Zawartosc fosforu calkowitego w przeliczeniu na P2O5\nZakres (1,000 – 15) g/kg\nMetoda spektrofotometryczna PN-ISO 13730:1999+Ap1:2004","categories":["food"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total phosphorus content calculated as P2O5","parameters_en":[{"name":"Range","range":"(1,000 – 15) g/kg"}],"search_en":"Meat and meat products Total phosphorus content calculated as P2O5 Spectrophotometric method Range PN-ISO 13730:1999+Ap1:2004","technique_en":"Spectrophotometric method","test_object_en":"Meat and meat products","parameters_zh":[{"name":"范围","range":"(1,000 – 15) g/kg"}],"search_zh":"肉与肉制品 分光光度法 范围 PN-ISO 13730:1999+Ap1:2004","technique_zh":"分光光度法","test_object_zh":"肉与肉制品"},{"_id":"6a836a14af14b9c0e7b1dead","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Mięso i przetwory mięsne","methodology":"Zawartość fosforu dodanego w przeliczeniu na P2O5 / Zawartość wielofosforanów dodanych w przeliczeniu na P2O5 (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość fosforu dodanego w przeliczeniu na P2O5 / Zawartość wielofosforanów dodanych w przeliczeniu na P2O5 (z obliczeń)","reference":"PN-A-82060:1999","norm_bases":["PN-A-82060:1999"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i przetwory mięsne Zawartość fosforu dodanego w przeliczeniu na P2O5 / Zawartość wielofosforanów dodanych w przeliczeniu na P2O5 (z obliczeń) PN-A-82060:1999 Mieso i przetwory miesne Zawartosc fosforu dodanego w przeliczeniu na P2O5 / Zawartosc wielofosforanow dodanych w przeliczeniu na P2O5 (z obliczen) PN-A-82060:1999","categories":["food"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Meat and meat products PN-A-82060:1999","test_object_en":"Meat and meat products","search_zh":"肉与肉制品 PN-A-82060:1999","test_object_zh":"肉与肉制品"},{"_id":"6a836a14af14b9c0e7b1deae","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Mięso i przetwory mięsne","methodology":"Zawartość hydroksyproliny","parameters":[{"name":"Zakres","range":"(0,08 − 0,50) %"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość hydroksyproliny\nZakres (0,08 − 0,50) %\nMetoda spektrofotometryczna","reference":"PN-ISO 3496:2000","norm_bases":["PN-ISO 3496:2000"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i przetwory mięsne Zawartość hydroksyproliny\nZakres (0,08 − 0,50) %\nMetoda spektrofotometryczna PN-ISO 3496:2000 Mieso i przetwory miesne Zawartosc hydroksyproliny\nZakres (0,08 − 0,50) %\nMetoda spektrofotometryczna PN-ISO 3496:2000","categories":["food"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydroxyproline content","parameters_en":[{"name":"Range","range":"(0,08 − 0,50) %"}],"search_en":"Meat and meat products Hydroxyproline content Spectrophotometric method Range PN-ISO 3496:2000","technique_en":"Spectrophotometric method","test_object_en":"Meat and meat products","parameters_zh":[{"name":"范围","range":"(0,08 − 0,50) %"}],"search_zh":"肉与肉制品 羟脯氨酸含量 分光光度法 范围 PN-ISO 3496:2000","technique_zh":"分光光度法","test_object_zh":"肉与肉制品","methodology_zh":"羟脯氨酸含量"},{"_id":"6a836a14af14b9c0e7b1deaf","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Mięso i przetwory mięsne","methodology":"Zawartość kolagenu, Zawartość tkanki łącznej / stosunek zawartości kolagenu do białka całkowitego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość kolagenu, Zawartość tkanki łącznej / stosunek zawartości kolagenu do białka całkowitego (z obliczeń)","reference":"Rozporządzenie Parlamentu Europejskiego i Rady (UE) Nr 1169/2011 z dnia 25.10.2011 r. Załącznik VII część B pkt. 17","norm_bases":["Rozporządzenie Parlamentu Europejskiego i Rady (UE) Nr 1169/2011 z dnia 25.10.2011 r. Załącznik VII część B pkt. 17"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i przetwory mięsne Zawartość kolagenu, Zawartość tkanki łącznej / stosunek zawartości kolagenu do białka całkowitego (z obliczeń) Rozporządzenie Parlamentu Europejskiego i Rady (UE) Nr 1169/2011 z dnia 25.10.2011 r. Załącznik VII część B pkt. 17 Mieso i przetwory miesne Zawartosc kolagenu, Zawartosc tkanki lacznej / stosunek zawartosci kolagenu do bialka calkowitego (z obliczen) Rozporzadzenie Parlamentu Europejskiego i Rady (UE) Nr 1169/2011 z dnia 25.10.2011 r. Zalacznik VII czesc B pkt. 17","categories":["food"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Collagen content, Connective tissue content / ratio of collagen content to total protein (calculated)","search_en":"Meat and meat products Collagen content, Connective tissue content / ratio of collagen content to total protein (calculated) Rozporządzenie Parlamentu Europejskiego i Rady (UE) Nr 1169/2011 z dnia 25.10.2011 r. Załącznik VII część B pkt. 17","test_object_en":"Meat and meat products","search_zh":"肉与肉制品 Rozporządzenie Parlamentu Europejskiego i Rady (UE) Nr 1169/2011 z dnia 25.10.2011 r. Załącznik VII część B pkt. 17","test_object_zh":"肉与肉制品"},{"_id":"6a836a14af14b9c0e7b1deb0","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Mięso i przetwory mięsne","methodology":"Zawartość skrobi","parameters":[{"name":"Zakres","range":"(0,02 − 18) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość skrobi\nZakres (0,02 − 18) %\nMetoda miareczkowa","reference":"PB/PACH/02 wydanie 2 z dnia 05.01.2021 r.","norm_bases":["PB/PACH/02 wydanie 2 z dnia 05.01.2021 r."],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i przetwory mięsne Zawartość skrobi\nZakres (0,02 − 18) %\nMetoda miareczkowa PB/PACH/02 wydanie 2 z dnia 05.01.2021 r. Mieso i przetwory miesne Zawartosc skrobi\nZakres (0,02 − 18) %\nMetoda miareczkowa PB/PACH/02 wydanie 2 z dnia 05.01.2021 r.","categories":["food"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Starch content","parameters_en":[{"name":"Range","range":"(0,02 − 18) %"}],"search_en":"Meat and meat products Starch content Titrimetric method Range PB/PACH/02 wydanie 2 z dnia 05.01.2021 r.","technique_en":"Titrimetric method","test_object_en":"Meat and meat products","parameters_zh":[{"name":"范围","range":"(0,02 − 18) %"}],"search_zh":"肉与肉制品 淀粉含量 滴定法 范围 PB/PACH/02 wydanie 2 z dnia 05.01.2021 r.","technique_zh":"滴定法","test_object_zh":"肉与肉制品","methodology_zh":"淀粉含量"},{"_id":"6a836a14af14b9c0e7b1deb1","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Mięso i przetwory mięsne","methodology":"Zawartość cukrów","parameters":[{"name":"Zakres","range":"(0,05 - 50,00)%"}],"technique":"Metoda miareczkowa (Luffa-Schoorla)","techniques":["Metoda miareczkowa (Luffa-Schoorla)"],"computed":[],"activity":"Zawartość cukrów\nZakres (0,05 - 50,00)%\nMetoda miareczkowa (Luffa-Schoorla)","reference":"PN-85/A-82100 pkt 2.5","norm_bases":["PN-85/A-82100 pkt 2.5"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i przetwory mięsne Zawartość cukrów\nZakres (0,05 - 50,00)%\nMetoda miareczkowa (Luffa-Schoorla) PN-85/A-82100 pkt 2.5 Mieso i przetwory miesne Zawartosc cukrow\nZakres (0,05 - 50,00)%\nMetoda miareczkowa (Luffa-Schoorla) PN-85/A-82100 pkt 2.5","categories":["food"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sugar content","parameters_en":[{"name":"Range","range":"(0,05 - 50,00)%"}],"search_en":"Meat and meat products Sugar content Titrimetric method (Luff-Schoorl) Range PN-85/A-82100 pkt 2.5","technique_en":"Titrimetric method (Luff-Schoorl)","test_object_en":"Meat and meat products","parameters_zh":[{"name":"范围","range":"(0,05 - 50,00)%"}],"search_zh":"肉与肉制品 糖含量 滴定法（Luff-Schoorl 法） 范围 PN-85/A-82100 pkt 2.5","test_object_zh":"肉与肉制品","methodology_zh":"糖含量","technique_zh":"滴定法（Luff-Schoorl 法）"},{"_id":"6a836a14af14b9c0e7b1deb2","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Mięso i przetwory mięsne","methodology":"Zawartość azotanów i azotynów","parameters":[{"name":"Azotany V","range":"(4 – 313) mg NO3-/kg"},{"name":"Azotany III","range":"(10 – 313) mg NO2-/kg"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)"],"computed":[],"activity":"Zawartość azotanów i azotynów\nZakres:\nAzotany V (4 – 313) mg NO3-/kg\nAzotany III (10 – 313) mg NO2-/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","reference":"PN-EN 12014-2:2018-01","norm_bases":["PN-EN 12014-2:2018-01"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i przetwory mięsne Zawartość azotanów i azotynów\nZakres:\nAzotany V (4 – 313) mg NO3-/kg\nAzotany III (10 – 313) mg NO2-/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV) PN-EN 12014-2:2018-01 Mieso i przetwory miesne Zawartosc azotanow i azotynow\nZakres:\nAzotany V (4 – 313) mg NO3-/kg\nAzotany III (10 – 313) mg NO2-/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC-UV) PN-EN 12014-2:2018-01","categories":["food"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate and nitrite content","parameters_en":[{"name":"Nitrates V","range":"(4 – 313) mg NO3-/kg"},{"name":"Nitrates III","range":"(10 – 313) mg NO2-/kg"}],"search_en":"Meat and meat products Nitrate and nitrite content High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) Nitrates V Nitrates III PN-EN 12014-2:2018-01","technique_en":"High-performance liquid chromatography with spectrophotometric detection (HPLC-UV)","test_object_en":"Meat and meat products","search_zh":"肉与肉制品 硝酸盐与亚硝酸盐含量 高效液相色谱-分光光度检测法（HPLC-UV） PN-EN 12014-2:2018-01","technique_zh":"高效液相色谱-分光光度检测法（HPLC-UV）","test_object_zh":"肉与肉制品","methodology_zh":"硝酸盐与亚硝酸盐含量"},{"_id":"6a836a14af14b9c0e7b1deb3","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Mięso i przetwory mięsne","methodology":"Zawartość jako azotyn sodu i azotan sodu, azotyn potasu i azotan potasu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość jako azotyn sodu i azotan sodu, azotyn potasu i azotan potasu (z obliczeń)","reference":"PB/PACH/72 wydanie 1 z dnia 26.03.2025 r.","norm_bases":["PB/PACH/72 wydanie 1 z dnia 26.03.2025 r."],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i przetwory mięsne Zawartość jako azotyn sodu i azotan sodu, azotyn potasu i azotan potasu (z obliczeń) PB/PACH/72 wydanie 1 z dnia 26.03.2025 r. Mieso i przetwory miesne Zawartosc jako azotyn sodu i azotan sodu, azotyn potasu i azotan potasu (z obliczen) PB/PACH/72 wydanie 1 z dnia 26.03.2025 r.","categories":["food"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content as sodium nitrite and sodium nitrate, potassium nitrite and potassium nitrate (calculated)","search_en":"Meat and meat products Content as sodium nitrite and sodium nitrate, potassium nitrite and potassium nitrate (calculated) PB/PACH/72 wydanie 1 z dnia 26.03.2025 r.","test_object_en":"Meat and meat products","search_zh":"肉与肉制品 PB/PACH/72 wydanie 1 z dnia 26.03.2025 r.","test_object_zh":"肉与肉制品"},{"_id":"6a836a14af14b9c0e7b1deb4","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Mięso i przetwory mięsne","methodology":"Zawartość tłuszczu","parameters":[{"name":"Zakres","range":"(0,30 – 46,70)%"}],"technique":"Analiza wagowa za pomocą hydrolizy i ekstrakcji wspomaganej mikrofalami (MAHE)","techniques":["Analiza wagowa za pomocą hydrolizy i ekstrakcji wspomaganej mikrofalami (MAHE)"],"computed":[],"activity":"Zawartość tłuszczu\nZakres (0,30 – 46,70)%\nAnaliza wagowa za pomocą hydrolizy i ekstrakcji wspomaganej mikrofalami (MAHE)","reference":"UNI 11949:2024","norm_bases":["UNI 11949:2024"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i przetwory mięsne Zawartość tłuszczu\nZakres (0,30 – 46,70)%\nAnaliza wagowa za pomocą hydrolizy i ekstrakcji wspomaganej mikrofalami (MAHE) UNI 11949:2024 Mieso i przetwory miesne Zawartosc tluszczu\nZakres (0,30 – 46,70)%\nAnaliza wagowa za pomoca hydrolizy i ekstrakcji wspomaganej mikrofalami (MAHE) UNI 11949:2024","categories":["food"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fat content","parameters_en":[{"name":"Range","range":"(0,30 – 46,70)%"}],"search_en":"Meat and meat products Fat content Gravimetric analysis by microwave-assisted hydrolysis and extraction (MAHE) Range UNI 11949:2024","technique_en":"Gravimetric analysis by microwave-assisted hydrolysis and extraction (MAHE)","test_object_en":"Meat and meat products","methodology_zh":"脂肪含量","parameters_zh":[{"name":"范围","range":"(0,30 – 46,70)%"}],"search_zh":"肉与肉制品 脂肪含量 范围 UNI 11949:2024","test_object_zh":"肉与肉制品"},{"_id":"6a836a14af14b9c0e7b1deb5","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Mięso i przetwory mięsne","methodology":"Zawartość białka","parameters":[{"name":"Zakres","range":"(5,2 - 48,9) %"}],"technique":"Metoda spektrometrii transmisyjnej w bliskiej podczerwieni (NIT) z wykorzystaniem kalibracji na sztucznych sieciach neuronowych (ANN)","techniques":["Metoda spektrometrii transmisyjnej w bliskiej podczerwieni (NIT) z wykorzystaniem kalibracji na sztucznych sieciach neuronowych (ANN)"],"computed":[],"activity":"Zawartość białka\nZakres (5,2 - 48,9) %\nMetoda spektrometrii transmisyjnej w bliskiej podczerwieni (NIT) z wykorzystaniem kalibracji na sztucznych sieciach neuronowych (ANN)","reference":"PN-A-82109:2010","norm_bases":["PN-A-82109:2010"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i przetwory mięsne Zawartość białka\nZakres (5,2 - 48,9) %\nMetoda spektrometrii transmisyjnej w bliskiej podczerwieni (NIT) z wykorzystaniem kalibracji na sztucznych sieciach neuronowych (ANN) PN-A-82109:2010 Mieso i przetwory miesne Zawartosc bialka\nZakres (5,2 - 48,9) %\nMetoda spektrometrii transmisyjnej w bliskiej podczerwieni (NIT) z wykorzystaniem kalibracji na sztucznych sieciach neuronowych (ANN) PN-A-82109:2010","categories":["food","metrology"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Protein content","parameters_en":[{"name":"Range","range":"(5,2 - 48,9) %"}],"search_en":"Meat and meat products Protein content Near-infrared transmission spectrometry (NIT) with artificial neural network (ANN) calibration Range PN-A-82109:2010","technique_en":"Near-infrared transmission spectrometry (NIT) with artificial neural network (ANN) calibration","test_object_en":"Meat and meat products","methodology_zh":"蛋白质含量","parameters_zh":[{"name":"范围","range":"(5,2 - 48,9) %"}],"search_zh":"肉与肉制品 蛋白质含量 近红外透射光谱法（NIT），采用人工神经网络（ANN）校准 范围 PN-A-82109:2010","test_object_zh":"肉与肉制品","technique_zh":"近红外透射光谱法（NIT），采用人工神经网络（ANN）校准"},{"_id":"6a836a14af14b9c0e7b1deb6","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Mięso i przetwory mięsne","methodology":"Zawartość tłuszczu","parameters":[{"name":"Zakres","range":"(0,9 - 65,9) %"}],"technique":"Metoda spektrometrii transmisyjnej w bliskiej podczerwieni (NIT) z wykorzystaniem kalibracji na sztucznych sieciach neuronowych (ANN)","techniques":["Metoda spektrometrii transmisyjnej w bliskiej podczerwieni (NIT) z wykorzystaniem kalibracji na sztucznych sieciach neuronowych (ANN)"],"computed":[],"activity":"Zawartość tłuszczu\nZakres (0,9 - 65,9) %\nMetoda spektrometrii transmisyjnej w bliskiej podczerwieni (NIT) z wykorzystaniem kalibracji na sztucznych sieciach neuronowych (ANN)","reference":"PN-A-82109:2010","norm_bases":["PN-A-82109:2010"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i przetwory mięsne Zawartość tłuszczu\nZakres (0,9 - 65,9) %\nMetoda spektrometrii transmisyjnej w bliskiej podczerwieni (NIT) z wykorzystaniem kalibracji na sztucznych sieciach neuronowych (ANN) PN-A-82109:2010 Mieso i przetwory miesne Zawartosc tluszczu\nZakres (0,9 - 65,9) %\nMetoda spektrometrii transmisyjnej w bliskiej podczerwieni (NIT) z wykorzystaniem kalibracji na sztucznych sieciach neuronowych (ANN) PN-A-82109:2010","categories":["food","metrology"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fat content","parameters_en":[{"name":"Range","range":"(0,9 - 65,9) %"}],"search_en":"Meat and meat products Fat content Near-infrared transmission spectrometry (NIT) with artificial neural network (ANN) calibration Range PN-A-82109:2010","technique_en":"Near-infrared transmission spectrometry (NIT) with artificial neural network (ANN) calibration","test_object_en":"Meat and meat products","methodology_zh":"脂肪含量","parameters_zh":[{"name":"范围","range":"(0,9 - 65,9) %"}],"search_zh":"肉与肉制品 脂肪含量 近红外透射光谱法（NIT），采用人工神经网络（ANN）校准 范围 PN-A-82109:2010","test_object_zh":"肉与肉制品","technique_zh":"近红外透射光谱法（NIT），采用人工神经网络（ANN）校准"},{"_id":"6a836a14af14b9c0e7b1deb7","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Mięso i przetwory mięsne","methodology":"Zawartość kwasów tłuszczowych nasyconych","parameters":[{"name":"Zakres","range":"(0,1 – 20,7) %"}],"technique":"Metoda spektrometrii transmisyjnej w bliskiej podczerwieni (NIT) z wykorzystaniem kalibracji na sztucznych sieciach neuronowych (ANN)","techniques":["Metoda spektrometrii transmisyjnej w bliskiej podczerwieni (NIT) z wykorzystaniem kalibracji na sztucznych sieciach neuronowych (ANN)"],"computed":[],"activity":"Zawartość kwasów tłuszczowych nasyconych\nZakres (0,1 – 20,7) %\nMetoda spektrometrii transmisyjnej w bliskiej podczerwieni (NIT) z wykorzystaniem kalibracji na sztucznych sieciach neuronowych (ANN)","reference":"PN-A-82109:2010","norm_bases":["PN-A-82109:2010"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i przetwory mięsne Zawartość kwasów tłuszczowych nasyconych\nZakres (0,1 – 20,7) %\nMetoda spektrometrii transmisyjnej w bliskiej podczerwieni (NIT) z wykorzystaniem kalibracji na sztucznych sieciach neuronowych (ANN) PN-A-82109:2010 Mieso i przetwory miesne Zawartosc kwasow tluszczowych nasyconych\nZakres (0,1 – 20,7) %\nMetoda spektrometrii transmisyjnej w bliskiej podczerwieni (NIT) z wykorzystaniem kalibracji na sztucznych sieciach neuronowych (ANN) PN-A-82109:2010","categories":["food","metrology"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Saturated fatty acid content","parameters_en":[{"name":"Range","range":"(0,1 – 20,7) %"}],"search_en":"Meat and meat products Saturated fatty acid content Near-infrared transmission spectrometry (NIT) with artificial neural network (ANN) calibration Range PN-A-82109:2010","technique_en":"Near-infrared transmission spectrometry (NIT) with artificial neural network (ANN) calibration","test_object_en":"Meat and meat products","parameters_zh":[{"name":"范围","range":"(0,1 – 20,7) %"}],"search_zh":"肉与肉制品 近红外透射光谱法（NIT），采用人工神经网络（ANN）校准 范围 PN-A-82109:2010","test_object_zh":"肉与肉制品","technique_zh":"近红外透射光谱法（NIT），采用人工神经网络（ANN）校准"},{"_id":"6a836a14af14b9c0e7b1deb8","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Mięso i przetwory mięsne","methodology":"Zawartość wody","parameters":[{"name":"Zakres","range":"(28,1 – 81,3) %"}],"technique":"Metoda spektrometrii transmisyjnej w bliskiej podczerwieni (NIT) z wykorzystaniem kalibracji na sztucznych sieciach neuronowych (ANN)","techniques":["Metoda spektrometrii transmisyjnej w bliskiej podczerwieni (NIT) z wykorzystaniem kalibracji na sztucznych sieciach neuronowych (ANN)"],"computed":[],"activity":"Zawartość wody\nZakres (28,1 – 81,3) %\nMetoda spektrometrii transmisyjnej w bliskiej podczerwieni (NIT) z wykorzystaniem kalibracji na sztucznych sieciach neuronowych (ANN)","reference":"PN-A-82109:2010","norm_bases":["PN-A-82109:2010"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i przetwory mięsne Zawartość wody\nZakres (28,1 – 81,3) %\nMetoda spektrometrii transmisyjnej w bliskiej podczerwieni (NIT) z wykorzystaniem kalibracji na sztucznych sieciach neuronowych (ANN) PN-A-82109:2010 Mieso i przetwory miesne Zawartosc wody\nZakres (28,1 – 81,3) %\nMetoda spektrometrii transmisyjnej w bliskiej podczerwieni (NIT) z wykorzystaniem kalibracji na sztucznych sieciach neuronowych (ANN) PN-A-82109:2010","categories":["water","food","metrology"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water content","parameters_en":[{"name":"Range","range":"(28,1 – 81,3) %"}],"search_en":"Meat and meat products Water content Near-infrared transmission spectrometry (NIT) with artificial neural network (ANN) calibration Range PN-A-82109:2010","technique_en":"Near-infrared transmission spectrometry (NIT) with artificial neural network (ANN) calibration","test_object_en":"Meat and meat products","methodology_zh":"水分含量","parameters_zh":[{"name":"范围","range":"(28,1 – 81,3) %"}],"search_zh":"肉与肉制品 水分含量 近红外透射光谱法（NIT），采用人工神经网络（ANN）校准 范围 PN-A-82109:2010","test_object_zh":"肉与肉制品","technique_zh":"近红外透射光谱法（NIT），采用人工神经网络（ANN）校准"},{"_id":"6a836a14af14b9c0e7b1deb9","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Mięso i przetwory mięsne","methodology":"Zawartość popiołu","parameters":[{"name":"Zakres","range":"(0,2 – 6,5) %"}],"technique":"Metoda spektrometrii transmisyjnej w bliskiej podczerwieni (NIT) z wykorzystaniem kalibracji na sztucznych sieciach neuronowych (ANN)","techniques":["Metoda spektrometrii transmisyjnej w bliskiej podczerwieni (NIT) z wykorzystaniem kalibracji na sztucznych sieciach neuronowych (ANN)"],"computed":[],"activity":"Zawartość popiołu\nZakres (0,2 – 6,5) %\nMetoda spektrometrii transmisyjnej w bliskiej podczerwieni (NIT) z wykorzystaniem kalibracji na sztucznych sieciach neuronowych (ANN)","reference":"PN-A-82109:2010","norm_bases":["PN-A-82109:2010"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i przetwory mięsne Zawartość popiołu\nZakres (0,2 – 6,5) %\nMetoda spektrometrii transmisyjnej w bliskiej podczerwieni (NIT) z wykorzystaniem kalibracji na sztucznych sieciach neuronowych (ANN) PN-A-82109:2010 Mieso i przetwory miesne Zawartosc popiolu\nZakres (0,2 – 6,5) %\nMetoda spektrometrii transmisyjnej w bliskiej podczerwieni (NIT) z wykorzystaniem kalibracji na sztucznych sieciach neuronowych (ANN) PN-A-82109:2010","categories":["food","metrology"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ash content","parameters_en":[{"name":"Range","range":"(0,2 – 6,5) %"}],"search_en":"Meat and meat products Ash content Near-infrared transmission spectrometry (NIT) with artificial neural network (ANN) calibration Range PN-A-82109:2010","technique_en":"Near-infrared transmission spectrometry (NIT) with artificial neural network (ANN) calibration","test_object_en":"Meat and meat products","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(0,2 – 6,5) %"}],"search_zh":"肉与肉制品 灰分含量 近红外透射光谱法（NIT），采用人工神经网络（ANN）校准 范围 PN-A-82109:2010","test_object_zh":"肉与肉制品","technique_zh":"近红外透射光谱法（NIT），采用人工神经网络（ANN）校准"},{"_id":"6a836a14af14b9c0e7b1deba","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Mięso i przetwory mięsne","methodology":"Zawartość cukrów","parameters":[{"name":"Zakres","range":"(0,1 – 4,1) %"}],"technique":"Metoda spektrometrii transmisyjnej w bliskiej podczerwieni (NIT) z wykorzystaniem kalibracji na sztucznych sieciach neuronowych (ANN)","techniques":["Metoda spektrometrii transmisyjnej w bliskiej podczerwieni (NIT) z wykorzystaniem kalibracji na sztucznych sieciach neuronowych (ANN)"],"computed":[],"activity":"Zawartość cukrów\nZakres (0,1 – 4,1) %\nMetoda spektrometrii transmisyjnej w bliskiej podczerwieni (NIT) z wykorzystaniem kalibracji na sztucznych sieciach neuronowych (ANN)","reference":"PN-A-82109:2010","norm_bases":["PN-A-82109:2010"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i przetwory mięsne Zawartość cukrów\nZakres (0,1 – 4,1) %\nMetoda spektrometrii transmisyjnej w bliskiej podczerwieni (NIT) z wykorzystaniem kalibracji na sztucznych sieciach neuronowych (ANN) PN-A-82109:2010 Mieso i przetwory miesne Zawartosc cukrow\nZakres (0,1 – 4,1) %\nMetoda spektrometrii transmisyjnej w bliskiej podczerwieni (NIT) z wykorzystaniem kalibracji na sztucznych sieciach neuronowych (ANN) PN-A-82109:2010","categories":["food","metrology"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sugar content","parameters_en":[{"name":"Range","range":"(0,1 – 4,1) %"}],"search_en":"Meat and meat products Sugar content Near-infrared transmission spectrometry (NIT) with artificial neural network (ANN) calibration Range PN-A-82109:2010","technique_en":"Near-infrared transmission spectrometry (NIT) with artificial neural network (ANN) calibration","test_object_en":"Meat and meat products","parameters_zh":[{"name":"范围","range":"(0,1 – 4,1) %"}],"search_zh":"肉与肉制品 糖含量 近红外透射光谱法（NIT），采用人工神经网络（ANN）校准 范围 PN-A-82109:2010","test_object_zh":"肉与肉制品","methodology_zh":"糖含量","technique_zh":"近红外透射光谱法（NIT），采用人工神经网络（ANN）校准"},{"_id":"6a836a14af14b9c0e7b1debb","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Mięso i przetwory mięsne","methodology":"Zawartość kolagenu","parameters":[{"name":"Zakres","range":"(0,1 – 7,2) %"}],"technique":"Metoda spektrometrii transmisyjnej w bliskiej podczerwieni (NIT) z wykorzystaniem kalibracji na sztucznych sieciach neuronowych (ANN)","techniques":["Metoda spektrometrii transmisyjnej w bliskiej podczerwieni (NIT) z wykorzystaniem kalibracji na sztucznych sieciach neuronowych (ANN)"],"computed":[],"activity":"Zawartość kolagenu\nZakres (0,1 – 7,2) %\nMetoda spektrometrii transmisyjnej w bliskiej podczerwieni (NIT) z wykorzystaniem kalibracji na sztucznych sieciach neuronowych (ANN)","reference":"PN-A-82109:2010","norm_bases":["PN-A-82109:2010"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i przetwory mięsne Zawartość kolagenu\nZakres (0,1 – 7,2) %\nMetoda spektrometrii transmisyjnej w bliskiej podczerwieni (NIT) z wykorzystaniem kalibracji na sztucznych sieciach neuronowych (ANN) PN-A-82109:2010 Mieso i przetwory miesne Zawartosc kolagenu\nZakres (0,1 – 7,2) %\nMetoda spektrometrii transmisyjnej w bliskiej podczerwieni (NIT) z wykorzystaniem kalibracji na sztucznych sieciach neuronowych (ANN) PN-A-82109:2010","categories":["food","metrology"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Collagen content","parameters_en":[{"name":"Range","range":"(0,1 – 7,2) %"}],"search_en":"Meat and meat products Collagen content Near-infrared transmission spectrometry (NIT) with artificial neural network (ANN) calibration Range PN-A-82109:2010","technique_en":"Near-infrared transmission spectrometry (NIT) with artificial neural network (ANN) calibration","test_object_en":"Meat and meat products","parameters_zh":[{"name":"范围","range":"(0,1 – 7,2) %"}],"search_zh":"肉与肉制品 胶原蛋白含量 近红外透射光谱法（NIT），采用人工神经网络（ANN）校准 范围 PN-A-82109:2010","test_object_zh":"肉与肉制品","technique_zh":"近红外透射光谱法（NIT），采用人工神经网络（ANN）校准","methodology_zh":"胶原蛋白含量"},{"_id":"6a836a14af14b9c0e7b1debc","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Mięso i przetwory mięsne","methodology":"Zawartość skrobi","parameters":[{"name":"Zakres","range":"(0,1 –11,0) %"}],"technique":"Metoda spektrometrii transmisyjnej w bliskiej podczerwieni (NIT) z wykorzystaniem kalibracji na sztucznych sieciach neuronowych (ANN)","techniques":["Metoda spektrometrii transmisyjnej w bliskiej podczerwieni (NIT) z wykorzystaniem kalibracji na sztucznych sieciach neuronowych (ANN)"],"computed":[],"activity":"Zawartość skrobi\nZakres (0,1 –11,0) %\nMetoda spektrometrii transmisyjnej w bliskiej podczerwieni (NIT) z wykorzystaniem kalibracji na sztucznych sieciach neuronowych (ANN)","reference":"PN-A-82109:2010","norm_bases":["PN-A-82109:2010"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i przetwory mięsne Zawartość skrobi\nZakres (0,1 –11,0) %\nMetoda spektrometrii transmisyjnej w bliskiej podczerwieni (NIT) z wykorzystaniem kalibracji na sztucznych sieciach neuronowych (ANN) PN-A-82109:2010 Mieso i przetwory miesne Zawartosc skrobi\nZakres (0,1 –11,0) %\nMetoda spektrometrii transmisyjnej w bliskiej podczerwieni (NIT) z wykorzystaniem kalibracji na sztucznych sieciach neuronowych (ANN) PN-A-82109:2010","categories":["food","metrology"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Starch content","parameters_en":[{"name":"Range","range":"(0,1 –11,0) %"}],"search_en":"Meat and meat products Starch content Near-infrared transmission spectrometry (NIT) with artificial neural network (ANN) calibration Range PN-A-82109:2010","technique_en":"Near-infrared transmission spectrometry (NIT) with artificial neural network (ANN) calibration","test_object_en":"Meat and meat products","parameters_zh":[{"name":"范围","range":"(0,1 –11,0) %"}],"search_zh":"肉与肉制品 淀粉含量 近红外透射光谱法（NIT），采用人工神经网络（ANN）校准 范围 PN-A-82109:2010","test_object_zh":"肉与肉制品","methodology_zh":"淀粉含量","technique_zh":"近红外透射光谱法（NIT），采用人工神经网络（ANN）校准"},{"_id":"6a836a14af14b9c0e7b1debd","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Mięso i przetwory mięsne","methodology":"Zawartość białka","parameters":[{"name":"Zakres","range":"(5,2 - 48,9) %"}],"technique":"Metoda spektrometrii transmisyjnej w bliskiej podczerwieni (NIT) z wykorzystaniem kalibracji na sztucznych sieciach neuronowych (ANN)","techniques":["Metoda spektrometrii transmisyjnej w bliskiej podczerwieni (NIT) z wykorzystaniem kalibracji na sztucznych sieciach neuronowych (ANN)"],"computed":[],"activity":"Zawartość białka\nZakres (5,2 - 48,9) %\nMetoda spektrometrii transmisyjnej w bliskiej podczerwieni (NIT) z wykorzystaniem kalibracji na sztucznych sieciach neuronowych (ANN)","reference":"PN-A-82109:2010","norm_bases":["PN-A-82109:2010"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i przetwory mięsne Zawartość białka\nZakres (5,2 - 48,9) %\nMetoda spektrometrii transmisyjnej w bliskiej podczerwieni (NIT) z wykorzystaniem kalibracji na sztucznych sieciach neuronowych (ANN) PN-A-82109:2010 Mieso i przetwory miesne Zawartosc bialka\nZakres (5,2 - 48,9) %\nMetoda spektrometrii transmisyjnej w bliskiej podczerwieni (NIT) z wykorzystaniem kalibracji na sztucznych sieciach neuronowych (ANN) PN-A-82109:2010","categories":["food","metrology"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Protein content","parameters_en":[{"name":"Range","range":"(5,2 - 48,9) %"}],"search_en":"Meat and meat products Protein content Near-infrared transmission spectrometry (NIT) with artificial neural network (ANN) calibration Range PN-A-82109:2010","technique_en":"Near-infrared transmission spectrometry (NIT) with artificial neural network (ANN) calibration","test_object_en":"Meat and meat products","methodology_zh":"蛋白质含量","parameters_zh":[{"name":"范围","range":"(5,2 - 48,9) %"}],"search_zh":"肉与肉制品 蛋白质含量 近红外透射光谱法（NIT），采用人工神经网络（ANN）校准 范围 PN-A-82109:2010","test_object_zh":"肉与肉制品","technique_zh":"近红外透射光谱法（NIT），采用人工神经网络（ANN）校准"},{"_id":"6a836a14af14b9c0e7b1debe","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Mięso i przetwory mięsne","methodology":"Zawartość sodu","parameters":[{"name":"Zakres","range":"(0,2 – 3,7) %"}],"technique":"Metoda spektrometrii transmisyjnej w bliskiej podczerwieni (NIT) z wykorzystaniem kalibracji na sztucznych sieciach neuronowych (ANN)","techniques":["Metoda spektrometrii transmisyjnej w bliskiej podczerwieni (NIT) z wykorzystaniem kalibracji na sztucznych sieciach neuronowych (ANN)"],"computed":[],"activity":"Zawartość sodu\nZakres (0,2 – 3,7) %\nMetoda spektrometrii transmisyjnej w bliskiej podczerwieni (NIT) z wykorzystaniem kalibracji na sztucznych sieciach neuronowych (ANN)","reference":"PN-A-82109:2010","norm_bases":["PN-A-82109:2010"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i przetwory mięsne Zawartość sodu\nZakres (0,2 – 3,7) %\nMetoda spektrometrii transmisyjnej w bliskiej podczerwieni (NIT) z wykorzystaniem kalibracji na sztucznych sieciach neuronowych (ANN) PN-A-82109:2010 Mieso i przetwory miesne Zawartosc sodu\nZakres (0,2 – 3,7) %\nMetoda spektrometrii transmisyjnej w bliskiej podczerwieni (NIT) z wykorzystaniem kalibracji na sztucznych sieciach neuronowych (ANN) PN-A-82109:2010","categories":["food","metrology"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sodium content","parameters_en":[{"name":"Range","range":"(0,2 – 3,7) %"}],"search_en":"Meat and meat products Sodium content Near-infrared transmission spectrometry (NIT) with artificial neural network (ANN) calibration Range PN-A-82109:2010","technique_en":"Near-infrared transmission spectrometry (NIT) with artificial neural network (ANN) calibration","test_object_en":"Meat and meat products","parameters_zh":[{"name":"范围","range":"(0,2 – 3,7) %"}],"search_zh":"肉与肉制品 钠含量 近红外透射光谱法（NIT），采用人工神经网络（ANN）校准 范围 PN-A-82109:2010","test_object_zh":"肉与肉制品","methodology_zh":"钠含量","technique_zh":"近红外透射光谱法（NIT），采用人工神经网络（ANN）校准"},{"_id":"6a836a14af14b9c0e7b1debf","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Mięso i przetwory mięsne","methodology":"Zawartość błonnika pokarmowego","parameters":[{"name":"Zakres","range":"(0,1 – 1,6) %"}],"technique":"Metoda spektrometrii transmisyjnej w bliskiej podczerwieni (NIT) z wykorzystaniem kalibracji na sztucznych sieciach neuronowych (ANN)","techniques":["Metoda spektrometrii transmisyjnej w bliskiej podczerwieni (NIT) z wykorzystaniem kalibracji na sztucznych sieciach neuronowych (ANN)"],"computed":[],"activity":"Zawartość błonnika pokarmowego\nZakres (0,1 – 1,6) %\nMetoda spektrometrii transmisyjnej w bliskiej podczerwieni (NIT) z wykorzystaniem kalibracji na sztucznych sieciach neuronowych (ANN)","reference":"PN-A-82109:2010","norm_bases":["PN-A-82109:2010"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i przetwory mięsne Zawartość błonnika pokarmowego\nZakres (0,1 – 1,6) %\nMetoda spektrometrii transmisyjnej w bliskiej podczerwieni (NIT) z wykorzystaniem kalibracji na sztucznych sieciach neuronowych (ANN) PN-A-82109:2010 Mieso i przetwory miesne Zawartosc blonnika pokarmowego\nZakres (0,1 – 1,6) %\nMetoda spektrometrii transmisyjnej w bliskiej podczerwieni (NIT) z wykorzystaniem kalibracji na sztucznych sieciach neuronowych (ANN) PN-A-82109:2010","categories":["food","metrology"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dietary fibre content","parameters_en":[{"name":"Range","range":"(0,1 – 1,6) %"}],"search_en":"Meat and meat products Dietary fibre content Near-infrared transmission spectrometry (NIT) with artificial neural network (ANN) calibration Range PN-A-82109:2010","technique_en":"Near-infrared transmission spectrometry (NIT) with artificial neural network (ANN) calibration","test_object_en":"Meat and meat products","parameters_zh":[{"name":"范围","range":"(0,1 – 1,6) %"}],"search_zh":"肉与肉制品 膳食纤维含量 近红外透射光谱法（NIT），采用人工神经网络（ANN）校准 范围 PN-A-82109:2010","test_object_zh":"肉与肉制品","methodology_zh":"膳食纤维含量","technique_zh":"近红外透射光谱法（NIT），采用人工神经网络（ANN）校准"},{"_id":"6a836a14af14b9c0e7b1dec0","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Oleje i tłuszcze roślinne i zwierzęce","methodology":"Liczba kwasowa","parameters":[{"name":"Zakres","range":"(0,06 – 75,0) mgKOH/g"},{"name":"Kwasowość /zawartość wolnych kwasów tłuszczowych w przeliczeniu na odpowiedni kwas"},{"name":"Zakres","range":"(0,03 – 37) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Liczba kwasowa\nZakres:\nZakres (0,06 – 75,0) mgKOH/g\nKwasowość /zawartość wolnych kwasów tłuszczowych w przeliczeniu na odpowiedni kwas\nZakres (0,03 – 37) %\nMetoda miareczkowa","reference":"PN-EN ISO 660:2021-03","norm_bases":["PN-EN ISO 660:2021-03"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Oleje i tłuszcze roślinne i zwierzęce Liczba kwasowa\nZakres:\nZakres (0,06 – 75,0) mgKOH/g\nKwasowość /zawartość wolnych kwasów tłuszczowych w przeliczeniu na odpowiedni kwas\nZakres (0,03 – 37) %\nMetoda miareczkowa PN-EN ISO 660:2021-03 Oleje i tluszcze roslinne i zwierzece Liczba kwasowa\nZakres:\nZakres (0,06 – 75,0) mgKOH/g\nKwasowosc /zawartosc wolnych kwasow tluszczowych w przeliczeniu na odpowiedni kwas\nZakres (0,03 – 37) %\nMetoda miareczkowa PN-EN ISO 660:2021-03","categories":["food","petro"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Acid value","parameters_en":[{"name":"Range","range":"(0,06 – 75,0) mgKOH/g"},{"name":"Acidity /free fatty acid content expressed as the corresponding acid"},{"name":"Range","range":"(0,03 – 37) %"}],"search_en":"Vegetable and animal oils and fats Acid value Titrimetric method Range Acidity /free fatty acid content expressed as the corresponding acid Range PN-EN ISO 660:2021-03","technique_en":"Titrimetric method","test_object_en":"Vegetable and animal oils and fats","parameters_zh":[{"name":"范围","range":"(0,06 – 75,0) mgKOH/g"},{"name":"Kwasowość /zawartość wolnych kwasów tłuszczowych w przeliczeniu na odpowiedni kwas"},{"name":"范围","range":"(0,03 – 37) %"}],"search_zh":"植物油脂与动物油脂 酸值 滴定法 范围 范围 PN-EN ISO 660:2021-03","technique_zh":"滴定法","methodology_zh":"酸值","test_object_zh":"植物油脂与动物油脂"},{"_id":"6a836a14af14b9c0e7b1dec1","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Oleje i tłuszcze roślinne i zwierzęce","methodology":"Liczba nadtlenkowa","parameters":[{"name":"Zakres","range":"(0,1 –30) meqO2/kg"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Liczba nadtlenkowa\nZakres (0,1 –30) meqO2/kg\nMetoda miareczkowa","reference":"PN-EN ISO 3960:2017-03","norm_bases":["PN-EN ISO 3960:2017-03"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Oleje i tłuszcze roślinne i zwierzęce Liczba nadtlenkowa\nZakres (0,1 –30) meqO2/kg\nMetoda miareczkowa PN-EN ISO 3960:2017-03 Oleje i tluszcze roslinne i zwierzece Liczba nadtlenkowa\nZakres (0,1 –30) meqO2/kg\nMetoda miareczkowa PN-EN ISO 3960:2017-03","categories":["food","petro"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Peroxide value","parameters_en":[{"name":"Range","range":"(0,1 –30) meqO2/kg"}],"search_en":"Vegetable and animal oils and fats Peroxide value Titrimetric method Range PN-EN ISO 3960:2017-03","technique_en":"Titrimetric method","test_object_en":"Vegetable and animal oils and fats","parameters_zh":[{"name":"范围","range":"(0,1 –30) meqO2/kg"}],"search_zh":"植物油脂与动物油脂 过氧化值 滴定法 范围 PN-EN ISO 3960:2017-03","technique_zh":"滴定法","test_object_zh":"植物油脂与动物油脂","methodology_zh":"过氧化值"},{"_id":"6a836a14af14b9c0e7b1dec2","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Oleje i tłuszcze roślinne i zwierzęce","methodology":"Liczba jodowa","parameters":[{"name":"Zakres","range":"(1 – 200) g/100g"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Liczba jodowa\nZakres (1 – 200) g/100g\nMetoda miareczkowa","reference":"PN-EN ISO 3961:2025-07","norm_bases":["PN-EN ISO 3961:2025-07"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Oleje i tłuszcze roślinne i zwierzęce Liczba jodowa\nZakres (1 – 200) g/100g\nMetoda miareczkowa PN-EN ISO 3961:2025-07 Oleje i tluszcze roslinne i zwierzece Liczba jodowa\nZakres (1 – 200) g/100g\nMetoda miareczkowa PN-EN ISO 3961:2025-07","categories":["food","petro"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Iodine value","parameters_en":[{"name":"Range","range":"(1 – 200) g/100g"}],"search_en":"Vegetable and animal oils and fats Iodine value Titrimetric method Range PN-EN ISO 3961:2025-07","technique_en":"Titrimetric method","test_object_en":"Vegetable and animal oils and fats","parameters_zh":[{"name":"范围","range":"(1 – 200) g/100g"}],"search_zh":"植物油脂与动物油脂 碘值 滴定法 范围 PN-EN ISO 3961:2025-07","technique_zh":"滴定法","test_object_zh":"植物油脂与动物油脂","methodology_zh":"碘值"},{"_id":"6a836a14af14b9c0e7b1dec3","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Koncentraty spożywcze, Mięso i produkty mięsne, Mleko i produkty mleczne, Napoje bezalkoholowe (gazowane, niegazowane, soki, syropy, nektary), Owoce i warzywa, przetwory owocowe i warzywne oraz warzywno-mięsne, Ryby i przetwory rybne, Słodycze i wyroby cukiernicze, Oleje i tłuszcze roślinne i zwierzęce, Zboża i przetwory zbożowe, Środki specjalnego przeznaczenia żywieniowego, Pasze","methodology":"Udział procentowy kwasów tłuszczowych, w tym izomerów trans","parameters":[{"name":"C4:0 kwas masłowy"},{"name":"C6:0 kwas kapronowy"},{"name":"C8:0 kwas kaprylowy"},{"name":"C10:0 kwas kaprynowy"},{"name":"C11:0 kwas undekanowy"},{"name":"C12:0 kwas laurynowy"},{"name":"C13:0 kwas tridekanowy"},{"name":"C14:0 kwas mirystynowy"},{"name":"C14:1 kwas mirystooleinowy"},{"name":"C15:0 kwas pentadekanowy"},{"name":"C15:1 kwas cis-10-pentadekenowy"},{"name":"C16:0 kwas palmitynowy"},{"name":"C16:1 kwas palmitooleinowy"},{"name":"C17:0 kwas heptadekanowy"},{"name":"C17:1 kwas cis-10-heptadekenowy"},{"name":"C18:0 kwasstearynowy"},{"name":"C18:1n9c kwas oleinowy"},{"name":"C18:1n9t kwas elaidynowy"},{"name":"C18:2n6c kwas linolowy"},{"name":"C18:2n6t kwas kwaslinoleadowy"},{"name":"C18:3n6 kwas γ-linolenowy"},{"name":"C18:3n3 kwas α-linolenowy"},{"name":"C20:0 kwas arachidowy"},{"name":"C20:1 kwas cis-11-gadoleinowy"},{"name":"C20:2 kwas cis-11,14-ikozadienowy"},{"name":"C20:3n6 kwas cis-8,11,14-ikozatrienowy"},{"name":"C20:3n3 kwas cis-11,14,17-ikozatrienowy"},{"name":"C20:4n6 kwas arachidonowy"},{"name":"C20:5n3 kwas cis-5,8,11,14,17-ikozapentaenowy"},{"name":"C21:0 kwas heneikozanowyheneikosanowy"},{"name":"C22:0 kwas behenowy"},{"name":"C22:1n9 kwas erukowy"},{"name":"C22:2 kwas cis-13,16-dokozadienowy"},{"name":"C22:6n3 kwas cis-4,7,10,13,16,19 dokozaheksaenowy"},{"name":"C23:0 kwas trikozanowy"},{"name":"C24:0 kwas lignocerynowy"},{"name":"C24:1 kwas nerwonowy"},{"name":"Zakres","range":"(0,10 -75) %, (m/m)"},{"name":"Zawartość /Suma kwasów tłuszczowych nasyconych Zawartość /suma kwasów tłuszczowych jednonienasyconych Zawartość/suma kwasów tłuszczowych wielonienasyconych Zawartość/suma kwasów tłuszczowych trans Zawartość /suma kwasów Omega 3 Zawartość /suma kwasów Omega 6 (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Udział procentowy kwasów tłuszczowych, w tym izomerów trans\nZakres:\nC4:0 kwas masłowy\nC6:0 kwas kapronowy\nC8:0 kwas kaprylowy\nC10:0 kwas kaprynowy\nC11:0 kwas undekanowy\nC12:0 kwas laurynowy\nC13:0 kwas tridekanowy\nC14:0 kwas mirystynowy\nC14:1 kwas mirystooleinowy\nC15:0 kwas pentadekanowy\nC15:1 kwas cis-10-pentadekenowy\nC16:0 kwas palmitynowy\nC16:1 kwas palmitooleinowy\nC17:0 kwas heptadekanowy\nC17:1 kwas cis-10-heptadekenowy\nC18:0 kwasstearynowy\nC18:1n9c kwas oleinowy\nC18:1n9t kwas elaidynowy\nC18:2n6c kwas linolowy\nC18:2n6t kwas kwaslinoleadowy\nC18:3n6 kwas γ-linolenowy\nC18:3n3 kwas α-linolenowy\nC20:0 kwas arachidowy\nC20:1 kwas cis-11-gadoleinowy\nC20:2 kwas cis-11,14-ikozadienowy\nC20:3n6 kwas cis-8,11,14-ikozatrienowy\nC20:3n3 kwas cis-11,14,17-ikozatrienowy\nC20:4n6 kwas arachidonowy\nC20:5n3 kwas cis-5,8,11,14,17-ikozapentaenowy\nC21:0 kwas heneikozanowyheneikosanowy\nC22:0 kwas behenowy\nC22:1n9 kwas erukowy\nC22:2 kwas cis-13,16-dokozadienowy\nC22:6n3 kwas cis-4,7,10,13,16,19 dokozaheksaenowy\nC23:0 kwas trikozanowy\nC24:0 kwas lignocerynowy\nC24:1 kwas nerwonowy\nZakres (0,10 -75) %, (m/m)\nZawartość /Suma kwasów tłuszczowych nasyconych Zawartość /suma kwasów tłuszczowych jednonienasyconych Zawartość/suma kwasów tłuszczowych wielonienasyconych Zawartość/suma kwasów tłuszczowych trans Zawartość /suma kwasów Omega 3 Zawartość /suma kwasów Omega 6 (z obliczeń)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PB/PACH/32 wydanie 2 z dnia 05.01.2021r.","norm_bases":["PB/PACH/32 wydanie 2 z dnia 05.01.2021r."],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Koncentraty spożywcze, Mięso i produkty mięsne, Mleko i produkty mleczne, Napoje bezalkoholowe (gazowane, niegazowane, soki, syropy, nektary), Owoce i warzywa, przetwory owocowe i warzywne oraz warzywno-mięsne, Ryby i przetwory rybne, Słodycze i wyroby cukiernicze, Oleje i tłuszcze roślinne i zwierzęce, Zboża i przetwory zbożowe, Środki specjalnego przeznaczenia żywieniowego, Pasze Udział procentowy kwasów tłuszczowych, w tym izomerów trans\nZakres:\nC4:0 kwas masłowy\nC6:0 kwas kapronowy\nC8:0 kwas kaprylowy\nC10:0 kwas kaprynowy\nC11:0 kwas undekanowy\nC12:0 kwas laurynowy\nC13:0 kwas tridekanowy\nC14:0 kwas mirystynowy\nC14:1 kwas mirystooleinowy\nC15:0 kwas pentadekanowy\nC15:1 kwas cis-10-pentadekenowy\nC16:0 kwas palmitynowy\nC16:1 kwas palmitooleinowy\nC17:0 kwas heptadekanowy\nC17:1 kwas cis-10-heptadekenowy\nC18:0 kwasstearynowy\nC18:1n9c kwas oleinowy\nC18:1n9t kwas elaidynowy\nC18:2n6c kwas linolowy\nC18:2n6t kwas kwaslinoleadowy\nC18:3n6 kwas γ-linolenowy\nC18:3n3 kwas α-linolenowy\nC20:0 kwas arachidowy\nC20:1 kwas cis-11-gadoleinowy\nC20:2 kwas cis-11,14-ikozadienowy\nC20:3n6 kwas cis-8,11,14-ikozatrienowy\nC20:3n3 kwas cis-11,14,17-ikozatrienowy\nC20:4n6 kwas arachidonowy\nC20:5n3 kwas cis-5,8,11,14,17-ikozapentaenowy\nC21:0 kwas heneikozanowyheneikosanowy\nC22:0 kwas behenowy\nC22:1n9 kwas erukowy\nC22:2 kwas cis-13,16-dokozadienowy\nC22:6n3 kwas cis-4,7,10,13,16,19 dokozaheksaenowy\nC23:0 kwas trikozanowy\nC24:0 kwas lignocerynowy\nC24:1 kwas nerwonowy\nZakres (0,10 -75) %, (m/m)\nZawartość /Suma kwasów tłuszczowych nasyconych Zawartość /suma kwasów tłuszczowych jednonienasyconych Zawartość/suma kwasów tłuszczowych wielonienasyconych Zawartość/suma kwasów tłuszczowych trans Zawartość /suma kwasów Omega 3 Zawartość /suma kwasów Omega 6 (z obliczeń)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PB/PACH/32 wydanie 2 z dnia 05.01.2021r. Koncentraty spozywcze, Mieso i produkty miesne, Mleko i produkty mleczne, Napoje bezalkoholowe (gazowane, niegazowane, soki, syropy, nektary), Owoce i warzywa, przetwory owocowe i warzywne oraz warzywno-miesne, Ryby i przetwory rybne, Slodycze i wyroby cukiernicze, Oleje i tluszcze roslinne i zwierzece, Zboza i przetwory zbozowe, Srodki specjalnego przeznaczenia zywieniowego, Pasze Udzial procentowy kwasow tluszczowych, w tym izomerow trans\nZakres:\nC4:0 kwas maslowy\nC6:0 kwas kapronowy\nC8:0 kwas kaprylowy\nC10:0 kwas kaprynowy\nC11:0 kwas undekanowy\nC12:0 kwas laurynowy\nC13:0 kwas tridekanowy\nC14:0 kwas mirystynowy\nC14:1 kwas mirystooleinowy\nC15:0 kwas pentadekanowy\nC15:1 kwas cis-10-pentadekenowy\nC16:0 kwas palmitynowy\nC16:1 kwas palmitooleinowy\nC17:0 kwas heptadekanowy\nC17:1 kwas cis-10-heptadekenowy\nC18:0 kwasstearynowy\nC18:1n9c kwas oleinowy\nC18:1n9t kwas elaidynowy\nC18:2n6c kwas linolowy\nC18:2n6t kwas kwaslinoleadowy\nC18:3n6 kwas γ-linolenowy\nC18:3n3 kwas α-linolenowy\nC20:0 kwas arachidowy\nC20:1 kwas cis-11-gadoleinowy\nC20:2 kwas cis-11,14-ikozadienowy\nC20:3n6 kwas cis-8,11,14-ikozatrienowy\nC20:3n3 kwas cis-11,14,17-ikozatrienowy\nC20:4n6 kwas arachidonowy\nC20:5n3 kwas cis-5,8,11,14,17-ikozapentaenowy\nC21:0 kwas heneikozanowyheneikosanowy\nC22:0 kwas behenowy\nC22:1n9 kwas erukowy\nC22:2 kwas cis-13,16-dokozadienowy\nC22:6n3 kwas cis-4,7,10,13,16,19 dokozaheksaenowy\nC23:0 kwas trikozanowy\nC24:0 kwas lignocerynowy\nC24:1 kwas nerwonowy\nZakres (0,10 -75) %, (m/m)\nZawartosc /Suma kwasow tluszczowych nasyconych Zawartosc /suma kwasow tluszczowych jednonienasyconych Zawartosc/suma kwasow tluszczowych wielonienasyconych Zawartosc/suma kwasow tluszczowych trans Zawartosc /suma kwasow Omega 3 Zawartosc /suma kwasow Omega 6 (z obliczen)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PB/PACH/32 wydanie 2 z dnia 05.01.2021r.","categories":["food","petro"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"C4:0 kwas masłowy"},{"name":"C6:0 kwas kapronowy"},{"name":"C8:0 kwas kaprylowy"},{"name":"C10:0 kwas kaprynowy"},{"name":"C11:0 kwas undekanowy"},{"name":"C12:0 kwas laurynowy"},{"name":"C13:0 kwas tridekanowy"},{"name":"C14:0 kwas mirystynowy"},{"name":"C14:1 kwas mirystooleinowy"},{"name":"C15:0 kwas pentadekanowy"},{"name":"C15:1 kwas cis-10-pentadekenowy"},{"name":"C16:0 kwas palmitynowy"},{"name":"C16:1 kwas palmitooleinowy"},{"name":"C17:0 kwas heptadekanowy"},{"name":"C17:1 kwas cis-10-heptadekenowy"},{"name":"C18:0 stearicacid"},{"name":"C18:1n9c kwas oleinowy"},{"name":"C18:1n9t kwas elaidynowy"},{"name":"C18:2n6c kwas linolowy"},{"name":"C18:2n6t kwas kwaslinoleadowy"},{"name":"C18:3n6 kwas γ-linolenowy"},{"name":"C18:3n3 kwas α-linolenowy"},{"name":"C20:0 arachidic acid"},{"name":"C20:1 kwas cis-11-gadoleinowy"},{"name":"C20:2 kwas cis-11,14-ikozadienowy"},{"name":"C20:3n6 kwas cis-8,11,14-ikozatrienowy"},{"name":"C20:3n3 kwas cis-11,14,17-ikozatrienowy"},{"name":"C20:4n6 kwas arachidonowy"},{"name":"C20:5n3 kwas cis-5,8,11,14,17-ikozapentaenowy"},{"name":"C21:0 kwas heneikozanowyheneikosanowy"},{"name":"C22:0 behenic acid"},{"name":"C22:1n9 kwas erukowy"},{"name":"C22:2 kwas cis-13,16-dokozadienowy"},{"name":"C22:6n3 kwas cis-4,7,10,13,16,19 dokozaheksaenowy"},{"name":"C23:0 tricosanoic acid"},{"name":"C24:0 lignoceric acid"},{"name":"C24:1 kwas nerwonowy"},{"name":"Range","range":"(0,10 -75) %, (m/m)"},{"name":"Content/Sum of saturated fatty acids Content/sum of monounsaturated fatty acids Content/sum of polyunsaturated fatty acids Content/sum of trans fatty acids Content/sum of Omega 3 acids Content/sum of Omega 6 acids (calculated)"}],"search_en":"Food concentrates, Meat and meat products, Milk and dairy products, Non-alcoholic beverages (carbonated, still, juices, syrups, nectars), Fruit and vegetables, fruit and vegetable products and vegetable-meat products, Fish and fish products, Sweets and confectionery, Vegetable and animal oils and fats, Cereals and cereal products, Foodstuffs for particular nutritional uses, Feed Gas chromatography with flame ionization detection (GC-FID) C18:0 stearicacid C20:0 arachidic acid C22:0 behenic acid C23:0 tricosanoic acid C24:0 lignoceric acid Range Content/Sum of saturated fatty acids Content/sum of monounsaturated fatty acids Content/sum of polyunsaturated fatty acids Content/sum of trans fatty acids Content/sum of Omega 3 acids Content/sum of Omega 6 acids (calculated) PB/PACH/32 wydanie 2 z dnia 05.01.2021r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Food concentrates, Meat and meat products, Milk and dairy products, Non-alcoholic beverages (carbonated, still, juices, syrups, nectars), Fruit and vegetables, fruit and vegetable products and vegetable-meat products, Fish and fish products, Sweets and confectionery, Vegetable and animal oils and fats, Cereals and cereal products, Foodstuffs for particular nutritional uses, Feed","parameters_zh":[{"name":"C4:0 kwas masłowy"},{"name":"C6:0 kwas kapronowy"},{"name":"C8:0 kwas kaprylowy"},{"name":"C10:0 kwas kaprynowy"},{"name":"C11:0 kwas undekanowy"},{"name":"C12:0 kwas laurynowy"},{"name":"C13:0 kwas tridekanowy"},{"name":"C14:0 kwas mirystynowy"},{"name":"C14:1 kwas mirystooleinowy"},{"name":"C15:0 kwas pentadekanowy"},{"name":"C15:1 kwas cis-10-pentadekenowy"},{"name":"C16:0 kwas palmitynowy"},{"name":"C16:1 kwas palmitooleinowy"},{"name":"C17:0 kwas heptadekanowy"},{"name":"C17:1 kwas cis-10-heptadekenowy"},{"name":"C18:0 kwasstearynowy"},{"name":"C18:1n9c kwas oleinowy"},{"name":"C18:1n9t kwas elaidynowy"},{"name":"C18:2n6c kwas linolowy"},{"name":"C18:2n6t kwas kwaslinoleadowy"},{"name":"C18:3n6 kwas γ-linolenowy"},{"name":"C18:3n3 kwas α-linolenowy"},{"name":"C20:0 kwas arachidowy"},{"name":"C20:1 kwas cis-11-gadoleinowy"},{"name":"C20:2 kwas cis-11,14-ikozadienowy"},{"name":"C20:3n6 kwas cis-8,11,14-ikozatrienowy"},{"name":"C20:3n3 kwas cis-11,14,17-ikozatrienowy"},{"name":"C20:4n6 kwas arachidonowy"},{"name":"C20:5n3 kwas cis-5,8,11,14,17-ikozapentaenowy"},{"name":"C21:0 kwas heneikozanowyheneikosanowy"},{"name":"C22:0 kwas behenowy"},{"name":"C22:1n9 kwas erukowy"},{"name":"C22:2 kwas cis-13,16-dokozadienowy"},{"name":"C22:6n3 kwas cis-4,7,10,13,16,19 dokozaheksaenowy"},{"name":"C23:0 kwas trikozanowy"},{"name":"C24:0 kwas lignocerynowy"},{"name":"C24:1 kwas nerwonowy"},{"name":"范围","range":"(0,10 -75) %, (m/m)"},{"name":"Zawartość /Suma kwasów tłuszczowych nasyconych Zawartość /suma kwasów tłuszczowych jednonienasyconych Zawartość/suma kwasów tłuszczowych wielonienasyconych Zawartość/suma kwasów tłuszczowych trans Zawartość /suma kwasów Omega 3 Zawartość /suma kwasów Omega 6 (z obliczeń)"}],"search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） 范围 PB/PACH/32 wydanie 2 z dnia 05.01.2021r.","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a836a14af14b9c0e7b1dec4","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Owoce i warzywa, Przetwory owocowe, warzywne warzywno-mięsne, Soki i nektary","methodology":"Zawartość chlorku sodu","parameters":[{"name":"Zakres","range":"(0,05 − 5,0) %"}],"technique":"Metoda miareczkowa (metoda Mohra)","techniques":["Metoda miareczkowa (metoda Mohra)"],"computed":[],"activity":"Zawartość chlorku sodu\nZakres (0,05 − 5,0) %\nMetoda miareczkowa (metoda Mohra)","reference":"PN-90/A-75101.10 +Az1:2002 pkt 2","norm_bases":["PN-90/A-75101.10 +Az1:2002 pkt 2"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Owoce i warzywa, Przetwory owocowe, warzywne warzywno-mięsne, Soki i nektary Zawartość chlorku sodu\nZakres (0,05 − 5,0) %\nMetoda miareczkowa (metoda Mohra) PN-90/A-75101.10 +Az1:2002 pkt 2 Owoce i warzywa, Przetwory owocowe, warzywne warzywno-miesne, Soki i nektary Zawartosc chlorku sodu\nZakres (0,05 − 5,0) %\nMetoda miareczkowa (metoda Mohra) PN-90/A-75101.10 +Az1:2002 pkt 2","categories":["other"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sodium chloride content","parameters_en":[{"name":"Range","range":"(0,05 − 5,0) %"}],"search_en":"Fruit and vegetables, Fruit, vegetable and vegetable-meat preserves, Juices and nectars Sodium chloride content Titrimetric method (Mohr method) Range PN-90/A-75101.10 +Az1:2002 pkt 2","technique_en":"Titrimetric method (Mohr method)","test_object_en":"Fruit and vegetables, Fruit, vegetable and vegetable-meat preserves, Juices and nectars","parameters_zh":[{"name":"范围","range":"(0,05 − 5,0) %"}],"search_zh":"水果与蔬菜，果蔬制品与蔬菜肉类制品，果汁与果蜜 氯化钠含量 范围 PN-90/A-75101.10 +Az1:2002 pkt 2","methodology_zh":"氯化钠含量","test_object_zh":"水果与蔬菜，果蔬制品与蔬菜肉类制品，果汁与果蜜"},{"_id":"6a836a14af14b9c0e7b1dec5","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Owoce i warzywa, Przetwory owocowe, warzywne warzywno-mięsne, Soki i nektary","methodology":"Kwasowość ogólna (w przeliczeniu na kwas stosowany)","parameters":[{"name":"Zakres","range":"(0,2 − 6,0) g/100 ml; g/100g"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Kwasowość ogólna (w przeliczeniu na kwas stosowany)\nZakres (0,2 − 6,0) g/100 ml; g/100g\nMetoda miareczkowa","reference":"PN-90/A-75101.04+Az1:2002 pkt 2 i pkt 3","norm_bases":["PN-90/A-75101.04+Az1:2002 pkt 2 i pkt 3"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Owoce i warzywa, Przetwory owocowe, warzywne warzywno-mięsne, Soki i nektary Kwasowość ogólna (w przeliczeniu na kwas stosowany)\nZakres (0,2 − 6,0) g/100 ml; g/100g\nMetoda miareczkowa PN-90/A-75101.04+Az1:2002 pkt 2 i pkt 3 Owoce i warzywa, Przetwory owocowe, warzywne warzywno-miesne, Soki i nektary Kwasowosc ogolna (w przeliczeniu na kwas stosowany)\nZakres (0,2 − 6,0) g/100 ml; g/100g\nMetoda miareczkowa PN-90/A-75101.04+Az1:2002 pkt 2 i pkt 3","categories":["other"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total acidity (expressed as the acid used)","parameters_en":[{"name":"Range","range":"(0,2 − 6,0) g/100 ml; g/100g"}],"search_en":"Fruit and vegetables, Fruit, vegetable and vegetable-meat preserves, Juices and nectars Total acidity (expressed as the acid used) Titrimetric method Range PN-90/A-75101.04+Az1:2002 pkt 2 i pkt 3","technique_en":"Titrimetric method","test_object_en":"Fruit and vegetables, Fruit, vegetable and vegetable-meat preserves, Juices and nectars","parameters_zh":[{"name":"范围","range":"(0,2 − 6,0) g/100 ml; g/100g"}],"search_zh":"水果与蔬菜，果蔬制品与蔬菜肉类制品，果汁与果蜜 滴定法 范围 PN-90/A-75101.04+Az1:2002 pkt 2 i pkt 3","technique_zh":"滴定法","test_object_zh":"水果与蔬菜，果蔬制品与蔬菜肉类制品，果汁与果蜜"},{"_id":"6a836a14af14b9c0e7b1dec6","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Owoce i warzywa, Przetwory owocowe, warzywne warzywno-mięsne, Soki i nektary","methodology":"Kwasowość lotna w przeliczeniu na kwas octowy","parameters":[{"name":"Zakres","range":"(0,001 – 5,0) %"}],"technique":"Metoda destylacyjno-miareczkowa","techniques":["Metoda destylacyjno-miareczkowa"],"computed":[],"activity":"Kwasowość lotna w przeliczeniu na kwas octowy\nZakres (0,001 – 5,0) %\nMetoda destylacyjno-miareczkowa","reference":"PN-90/A-75101.05 pkt 2","norm_bases":["PN-90/A-75101.05 pkt 2"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Owoce i warzywa, Przetwory owocowe, warzywne warzywno-mięsne, Soki i nektary Kwasowość lotna w przeliczeniu na kwas octowy\nZakres (0,001 – 5,0) %\nMetoda destylacyjno-miareczkowa PN-90/A-75101.05 pkt 2 Owoce i warzywa, Przetwory owocowe, warzywne warzywno-miesne, Soki i nektary Kwasowosc lotna w przeliczeniu na kwas octowy\nZakres (0,001 – 5,0) %\nMetoda destylacyjno-miareczkowa PN-90/A-75101.05 pkt 2","categories":["other"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Volatile acidity expressed as acetic acid","parameters_en":[{"name":"Range","range":"(0,001 – 5,0) %"}],"search_en":"Fruit and vegetables, Fruit, vegetable and vegetable-meat preserves, Juices and nectars Volatile acidity expressed as acetic acid Distillation-titrimetric method Range PN-90/A-75101.05 pkt 2","technique_en":"Distillation-titrimetric method","test_object_en":"Fruit and vegetables, Fruit, vegetable and vegetable-meat preserves, Juices and nectars","parameters_zh":[{"name":"范围","range":"(0,001 – 5,0) %"}],"search_zh":"水果与蔬菜，果蔬制品与蔬菜肉类制品，果汁与果蜜 蒸馏-滴定法 范围 PN-90/A-75101.05 pkt 2","technique_zh":"蒸馏-滴定法","test_object_zh":"水果与蔬菜，果蔬制品与蔬菜肉类制品，果汁与果蜜"},{"_id":"6a836a14af14b9c0e7b1dec7","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Owoce i warzywa, Przetwory owocowe, warzywne warzywno-mięsne, Soki i nektary","methodology":"Masa netto odciekniętych owoców / warzyw","parameters":[{"name":"Zakres","range":"(0,01 − 3000) g"},{"name":"Stosunek masy netto do masy odciekniętych owoców / warzyw (z obliczeń)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Masa netto odciekniętych owoców / warzyw\nZakres:\nZakres (0,01 − 3000) g\nStosunek masy netto do masy odciekniętych owoców / warzyw (z obliczeń)\nMetoda wagowa","reference":"PN-90/A-75101.15 pkt 3","norm_bases":["PN-90/A-75101.15 pkt 3"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Owoce i warzywa, Przetwory owocowe, warzywne warzywno-mięsne, Soki i nektary Masa netto odciekniętych owoców / warzyw\nZakres:\nZakres (0,01 − 3000) g\nStosunek masy netto do masy odciekniętych owoców / warzyw (z obliczeń)\nMetoda wagowa PN-90/A-75101.15 pkt 3 Owoce i warzywa, Przetwory owocowe, warzywne warzywno-miesne, Soki i nektary Masa netto odcieknietych owocow / warzyw\nZakres:\nZakres (0,01 − 3000) g\nStosunek masy netto do masy odcieknietych owocow / warzyw (z obliczen)\nMetoda wagowa PN-90/A-75101.15 pkt 3","categories":["other"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Net drained mass of fruit / vegetables","parameters_en":[{"name":"Range","range":"(0,01 − 3000) g"},{"name":"Ratio of net mass to drained mass of fruit / vegetables (calculated)"}],"search_en":"Fruit and vegetables, Fruit, vegetable and vegetable-meat preserves, Juices and nectars Net drained mass of fruit / vegetables Gravimetric method Range Ratio of net mass to drained mass of fruit / vegetables (calculated) PN-90/A-75101.15 pkt 3","technique_en":"Gravimetric method","test_object_en":"Fruit and vegetables, Fruit, vegetable and vegetable-meat preserves, Juices and nectars","parameters_zh":[{"name":"范围","range":"(0,01 − 3000) g"},{"name":"Stosunek masy netto do masy odciekniętych owoców / warzyw (z obliczeń)"}],"search_zh":"水果与蔬菜，果蔬制品与蔬菜肉类制品，果汁与果蜜 重量法 范围 PN-90/A-75101.15 pkt 3","technique_zh":"重量法","test_object_zh":"水果与蔬菜，果蔬制品与蔬菜肉类制品，果汁与果蜜"},{"_id":"6a836a14af14b9c0e7b1dec8","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Owoce i warzywa, Przetwory owocowe, warzywne warzywno-mięsne, Soki i nektary","methodology":"Zawartość ekstraktu bezcukrowego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość ekstraktu bezcukrowego (z obliczeń)","reference":"PN-90/A-75101.07 pkt 3","norm_bases":["PN-90/A-75101.07 pkt 3"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Owoce i warzywa, Przetwory owocowe, warzywne warzywno-mięsne, Soki i nektary Zawartość ekstraktu bezcukrowego (z obliczeń) PN-90/A-75101.07 pkt 3 Owoce i warzywa, Przetwory owocowe, warzywne warzywno-miesne, Soki i nektary Zawartosc ekstraktu bezcukrowego (z obliczen) PN-90/A-75101.07 pkt 3","categories":["other"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sugar-free extract content (calculated)","search_en":"Fruit and vegetables, Fruit, vegetable and vegetable-meat preserves, Juices and nectars Sugar-free extract content (calculated) PN-90/A-75101.07 pkt 3","test_object_en":"Fruit and vegetables, Fruit, vegetable and vegetable-meat preserves, Juices and nectars","methodology_zh":"无糖浸出物含量（由计算得出）","search_zh":"水果与蔬菜，果蔬制品与蔬菜肉类制品，果汁与果蜜 无糖浸出物含量（由计算得出） PN-90/A-75101.07 pkt 3","test_object_zh":"水果与蔬菜，果蔬制品与蔬菜肉类制品，果汁与果蜜"},{"_id":"6a836a14af14b9c0e7b1dec9","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Owoce i warzywa, Przetwory owocowe, warzywne warzywno-mięsne","methodology":"Zawartość ekstraktu ogólnego","parameters":[{"name":"Zakres","range":"(1,0 − 80) %"}],"technique":"Metoda refraktometryczna","techniques":["Metoda refraktometryczna"],"computed":[],"activity":"Zawartość ekstraktu ogólnego\nZakres (1,0 − 80) %\nMetoda refraktometryczna","reference":"PN-90/A-75101.02+Az1:2002 pkt 2","norm_bases":["PN-90/A-75101.02+Az1:2002 pkt 2"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Owoce i warzywa, Przetwory owocowe, warzywne warzywno-mięsne Zawartość ekstraktu ogólnego\nZakres (1,0 − 80) %\nMetoda refraktometryczna PN-90/A-75101.02+Az1:2002 pkt 2 Owoce i warzywa, Przetwory owocowe, warzywne warzywno-miesne Zawartosc ekstraktu ogolnego\nZakres (1,0 − 80) %\nMetoda refraktometryczna PN-90/A-75101.02+Az1:2002 pkt 2","categories":["other"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total extract content","parameters_en":[{"name":"Range","range":"(1,0 − 80) %"}],"search_en":"Fruit and vegetables, Fruit, vegetable and vegetable-meat products Total extract content Refractometric method Range PN-90/A-75101.02+Az1:2002 pkt 2","technique_en":"Refractometric method","test_object_en":"Fruit and vegetables, Fruit, vegetable and vegetable-meat products","parameters_zh":[{"name":"范围","range":"(1,0 − 80) %"}],"search_zh":"总浸出物含量 折射法 范围 PN-90/A-75101.02+Az1:2002 pkt 2","technique_zh":"折射法","methodology_zh":"总浸出物含量"},{"_id":"6a836a14af14b9c0e7b1deca","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Żywność pochodzenia roślinnego (warzywa i przetwory warzywne, owocowo-warzywne, owoce)","methodology":"Zawartość azotanów i azotynów","parameters":[{"name":"Azotany V","range":"(3 – 12481) mg NO3-/kg"},{"name":"Azotany III","range":"(3 – 6518) mg NO2-/kg"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)"],"computed":[],"activity":"Zawartość azotanów i azotynów\nZakres:\nAzotany V (3 – 12481) mg NO3-/kg\nAzotany III (3 – 6518) mg NO2-/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","reference":"PN-EN 12014-2:2018-01","norm_bases":["PN-EN 12014-2:2018-01"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Żywność pochodzenia roślinnego (warzywa i przetwory warzywne, owocowo-warzywne, owoce) Zawartość azotanów i azotynów\nZakres:\nAzotany V (3 – 12481) mg NO3-/kg\nAzotany III (3 – 6518) mg NO2-/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV) PN-EN 12014-2:2018-01 Zywnosc pochodzenia roslinnego (warzywa i przetwory warzywne, owocowo-warzywne, owoce) Zawartosc azotanow i azotynow\nZakres:\nAzotany V (3 – 12481) mg NO3-/kg\nAzotany III (3 – 6518) mg NO2-/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC-UV) PN-EN 12014-2:2018-01","categories":["food"],"row_index":55,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate and nitrite content","parameters_en":[{"name":"Nitrates V","range":"(3 – 12481) mg NO3-/kg"},{"name":"Nitrates III","range":"(3 – 6518) mg NO2-/kg"}],"search_en":"Food of plant origin (vegetables and vegetable preserves, fruit-vegetable preserves, fruits) Nitrate and nitrite content High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) Nitrates V Nitrates III PN-EN 12014-2:2018-01","technique_en":"High-performance liquid chromatography with spectrophotometric detection (HPLC-UV)","test_object_en":"Food of plant origin (vegetables and vegetable preserves, fruit-vegetable preserves, fruits)","search_zh":"硝酸盐与亚硝酸盐含量 高效液相色谱-分光光度检测法（HPLC-UV） PN-EN 12014-2:2018-01","technique_zh":"高效液相色谱-分光光度检测法（HPLC-UV）","methodology_zh":"硝酸盐与亚硝酸盐含量"},{"_id":"6a836a14af14b9c0e7b1decb","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Przetwory owocowe i warzywne, Suszone owoce i warzywa, Wiórki kokosowe, Grzyby marynowane, Żelatyna, skrobia, Mąka ziemniaczana","methodology":"Zawartość całkowitego dwutlenku siarki","parameters":[{"name":"Zakres","range":"(5,0 - 4000) mg/kg"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość całkowitego dwutlenku siarki\nZakres (5,0 - 4000) mg/kg\nMetoda miareczkowa","reference":"PN-90/A-75101/23 pkt 3+Az2:2002","norm_bases":["PN-90/A-75101/23 pkt 3+Az2:2002"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przetwory owocowe i warzywne, Suszone owoce i warzywa, Wiórki kokosowe, Grzyby marynowane, Żelatyna, skrobia, Mąka ziemniaczana Zawartość całkowitego dwutlenku siarki\nZakres (5,0 - 4000) mg/kg\nMetoda miareczkowa PN-90/A-75101/23 pkt 3+Az2:2002 Przetwory owocowe i warzywne, Suszone owoce i warzywa, Wiorki kokosowe, Grzyby marynowane, Zelatyna, skrobia, Maka ziemniaczana Zawartosc calkowitego dwutlenku siarki\nZakres (5,0 - 4000) mg/kg\nMetoda miareczkowa PN-90/A-75101/23 pkt 3+Az2:2002","categories":["microbiology"],"row_index":56,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total sulphur dioxide content","parameters_en":[{"name":"Range","range":"(5,0 - 4000) mg/kg"}],"search_en":"Fruit and vegetable products, Dried fruit and vegetables, Desiccated coconut, Marinated mushrooms, Gelatine, starch, Potato flour Total sulphur dioxide content Titrimetric method Range PN-90/A-75101/23 pkt 3+Az2:2002","technique_en":"Titrimetric method","test_object_en":"Fruit and vegetable products, Dried fruit and vegetables, Desiccated coconut, Marinated mushrooms, Gelatine, starch, Potato flour","parameters_zh":[{"name":"范围","range":"(5,0 - 4000) mg/kg"}],"search_zh":"滴定法 范围 PN-90/A-75101/23 pkt 3+Az2:2002","technique_zh":"滴定法"},{"_id":"6a836a14af14b9c0e7b1decc","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Soki owocowe i warzywne, Napoje, Octy, Wina","methodology":"Zawartość całkowitego dwutlenku siarki","parameters":[{"name":"Zakres","range":"(5,0 - 3000 ) mg/kg; mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość całkowitego dwutlenku siarki\nZakres (5,0 - 3000 ) mg/kg; mg/l\nMetoda miareczkowa","reference":"PN-EN 13196:2002","norm_bases":["PN-EN 13196:2002"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Soki owocowe i warzywne, Napoje, Octy, Wina Zawartość całkowitego dwutlenku siarki\nZakres (5,0 - 3000 ) mg/kg; mg/l\nMetoda miareczkowa PN-EN 13196:2002 Soki owocowe i warzywne, Napoje, Octy, Wina Zawartosc calkowitego dwutlenku siarki\nZakres (5,0 - 3000 ) mg/kg; mg/l\nMetoda miareczkowa PN-EN 13196:2002","categories":["food"],"row_index":57,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total sulphur dioxide content","parameters_en":[{"name":"Range","range":"(5,0 - 3000 ) mg/kg; mg/l"}],"search_en":"Fruit and vegetable juices, Beverages, Vinegars, Wines Total sulphur dioxide content Titrimetric method Range PN-EN 13196:2002","technique_en":"Titrimetric method","test_object_en":"Fruit and vegetable juices, Beverages, Vinegars, Wines","parameters_zh":[{"name":"范围","range":"(5,0 - 3000 ) mg/kg; mg/l"}],"search_zh":"滴定法 范围 PN-EN 13196:2002","technique_zh":"滴定法"},{"_id":"6a836a14af14b9c0e7b1decd","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Soki owocowe, Soki owocowo-warzywne, Nektary, Napoje gazowane, Napoje niegazowane","methodology":"Zawartość alkoholu etylowego","parameters":[{"name":"Zakres","range":"(0,01 – 3,00) g/l"}],"technique":"Metoda enzymatyczno-spektrofotometryczna","techniques":["Metoda enzymatyczno-spektrofotometryczna"],"computed":[],"activity":"Zawartość alkoholu etylowego\nZakres (0,01 – 3,00) g/l\nMetoda enzymatyczno-spektrofotometryczna","reference":"AOAC Method 2019.08","norm_bases":["AOAC Method 2019.08"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Soki owocowe, Soki owocowo-warzywne, Nektary, Napoje gazowane, Napoje niegazowane Zawartość alkoholu etylowego\nZakres (0,01 – 3,00) g/l\nMetoda enzymatyczno-spektrofotometryczna AOAC Method 2019.08 Soki owocowe, Soki owocowo-warzywne, Nektary, Napoje gazowane, Napoje niegazowane Zawartosc alkoholu etylowego\nZakres (0,01 – 3,00) g/l\nMetoda enzymatyczno-spektrofotometryczna AOAC Method 2019.08","categories":["food"],"row_index":58,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ethyl alcohol content","parameters_en":[{"name":"Range","range":"(0,01 – 3,00) g/l"}],"search_en":"Fruit juices, Fruit-vegetable juices, Nectars, Carbonated beverages, Still beverages Ethyl alcohol content Range AOAC Method 2019.08","test_object_en":"Fruit juices, Fruit-vegetable juices, Nectars, Carbonated beverages, Still beverages","parameters_zh":[{"name":"范围","range":"(0,01 – 3,00) g/l"}],"search_zh":"乙醇含量 范围 AOAC Method 2019.08","methodology_zh":"乙醇含量"},{"_id":"6a836a14af14b9c0e7b1dece","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Piwo","methodology":"Zawartość alkoholu etylowego","parameters":[{"name":"Zakres","range":"(0,02 – 6,5) %(V/V)"}],"technique":"Metoda enzymatyczno-spektrofotometryczna","techniques":["Metoda enzymatyczno-spektrofotometryczna"],"computed":[],"activity":"Zawartość alkoholu etylowego\nZakres (0,02 – 6,5) %(V/V)\nMetoda enzymatyczno-spektrofotometryczna","reference":"AOAC Method 2019.08","norm_bases":["AOAC Method 2019.08"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Piwo Zawartość alkoholu etylowego\nZakres (0,02 – 6,5) %(V/V)\nMetoda enzymatyczno-spektrofotometryczna AOAC Method 2019.08 Piwo Zawartosc alkoholu etylowego\nZakres (0,02 – 6,5) %(V/V)\nMetoda enzymatyczno-spektrofotometryczna AOAC Method 2019.08","categories":["other"],"row_index":59,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ethyl alcohol content","parameters_en":[{"name":"Range","range":"(0,02 – 6,5) %(V/V)"}],"search_en":"Beer Ethyl alcohol content Range AOAC Method 2019.08","test_object_en":"Beer","parameters_zh":[{"name":"范围","range":"(0,02 – 6,5) %(V/V)"}],"search_zh":"啤酒 乙醇含量 范围 AOAC Method 2019.08","test_object_zh":"啤酒","methodology_zh":"乙醇含量"},{"_id":"6a836a14af14b9c0e7b1decf","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Wina","methodology":"Zawartość alkoholu etylowego","parameters":[{"name":"Zakres","range":"(0,02 – 20,0) %(V/V)"}],"technique":"Metoda enzymatyczno-spektrofotometryczna","techniques":["Metoda enzymatyczno-spektrofotometryczna"],"computed":[],"activity":"Zawartość alkoholu etylowego\nZakres (0,02 – 20,0) %(V/V)\nMetoda enzymatyczno-spektrofotometryczna","reference":"AOAC Method 2019.08","norm_bases":["AOAC Method 2019.08"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wina Zawartość alkoholu etylowego\nZakres (0,02 – 20,0) %(V/V)\nMetoda enzymatyczno-spektrofotometryczna AOAC Method 2019.08 Wina Zawartosc alkoholu etylowego\nZakres (0,02 – 20,0) %(V/V)\nMetoda enzymatyczno-spektrofotometryczna AOAC Method 2019.08","categories":["other"],"row_index":60,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ethyl alcohol content","parameters_en":[{"name":"Range","range":"(0,02 – 20,0) %(V/V)"}],"search_en":"Wines Ethyl alcohol content Range AOAC Method 2019.08","test_object_en":"Wines","parameters_zh":[{"name":"范围","range":"(0,02 – 20,0) %(V/V)"}],"search_zh":"葡萄酒 乙醇含量 范围 AOAC Method 2019.08","methodology_zh":"乙醇含量","test_object_zh":"葡萄酒"},{"_id":"6a836a14af14b9c0e7b1ded0","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Napoje spirytusowe","methodology":"Zawartość alkoholu etylowego","parameters":[{"name":"Zakres","range":"(30,0 – 95,0) %(V/V)"}],"technique":"Metoda enzymatyczno-spektrofotometryczna","techniques":["Metoda enzymatyczno-spektrofotometryczna"],"computed":[],"activity":"Zawartość alkoholu etylowego\nZakres (30,0 – 95,0) %(V/V)\nMetoda enzymatyczno-spektrofotometryczna","reference":"AOAC Method 2019.08","norm_bases":["AOAC Method 2019.08"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Napoje spirytusowe Zawartość alkoholu etylowego\nZakres (30,0 – 95,0) %(V/V)\nMetoda enzymatyczno-spektrofotometryczna AOAC Method 2019.08 Napoje spirytusowe Zawartosc alkoholu etylowego\nZakres (30,0 – 95,0) %(V/V)\nMetoda enzymatyczno-spektrofotometryczna AOAC Method 2019.08","categories":["food"],"row_index":61,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ethyl alcohol content","parameters_en":[{"name":"Range","range":"(30,0 – 95,0) %(V/V)"}],"search_en":"Spirit drinks Ethyl alcohol content Range AOAC Method 2019.08","test_object_en":"Spirit drinks","parameters_zh":[{"name":"范围","range":"(30,0 – 95,0) %(V/V)"}],"search_zh":"烈性酒 乙醇含量 范围 AOAC Method 2019.08","methodology_zh":"乙醇含量","test_object_zh":"烈性酒"},{"_id":"6a836a14af14b9c0e7b1ded1","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Soki i nektary","methodology":"Kwasowość w przeliczeniu na kwas stosowany","parameters":[{"name":"Zakres","range":"(0,2 − 6,0) g/100 ml"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Kwasowość w przeliczeniu na kwas stosowany\nZakres (0,2 − 6,0) g/100 ml\nMetoda miareczkowa","reference":"PN-EN-12147:2000","norm_bases":["PN-EN-12147:2000"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Soki i nektary Kwasowość w przeliczeniu na kwas stosowany\nZakres (0,2 − 6,0) g/100 ml\nMetoda miareczkowa PN-EN-12147:2000 Soki i nektary Kwasowosc w przeliczeniu na kwas stosowany\nZakres (0,2 − 6,0) g/100 ml\nMetoda miareczkowa PN-EN-12147:2000","categories":["other"],"row_index":62,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Acidity expressed as the acid used","parameters_en":[{"name":"Range","range":"(0,2 − 6,0) g/100 ml"}],"search_en":"Juices and nectars Acidity expressed as the acid used Titrimetric method Range PN-EN-12147:2000","technique_en":"Titrimetric method","test_object_en":"Juices and nectars","parameters_zh":[{"name":"范围","range":"(0,2 − 6,0) g/100 ml"}],"search_zh":"滴定法 范围 PN-EN-12147:2000","technique_zh":"滴定法"},{"_id":"6a836a14af14b9c0e7b1ded2","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Soki i nektary","methodology":"Zawartość ekstraktu ogólnego","parameters":[{"name":"Zakres","range":"(2,0 − 70,0)%"}],"technique":"Metoda refraktometryczna","techniques":["Metoda refraktometryczna"],"computed":[],"activity":"Zawartość ekstraktu ogólnego\nZakres (2,0 − 70,0)%\nMetoda refraktometryczna","reference":"PN-EN 12143:2000","norm_bases":["PN-EN 12143:2000"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Soki i nektary Zawartość ekstraktu ogólnego\nZakres (2,0 − 70,0)%\nMetoda refraktometryczna PN-EN 12143:2000 Soki i nektary Zawartosc ekstraktu ogolnego\nZakres (2,0 − 70,0)%\nMetoda refraktometryczna PN-EN 12143:2000","categories":["other"],"row_index":63,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total extract content","parameters_en":[{"name":"Range","range":"(2,0 − 70,0)%"}],"search_en":"Juices and nectars Total extract content Refractometric method Range PN-EN 12143:2000","technique_en":"Refractometric method","test_object_en":"Juices and nectars","parameters_zh":[{"name":"范围","range":"(2,0 − 70,0)%"}],"search_zh":"总浸出物含量 折射法 范围 PN-EN 12143:2000","technique_zh":"折射法","methodology_zh":"总浸出物含量"},{"_id":"6a836a14af14b9c0e7b1ded3","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Koncentraty spożywcze","methodology":"Zawartość chlorku sodu","parameters":[{"name":"Zakres","range":"(0,25 − 60) %"}],"technique":"Metoda miareczkowa (Mohra)","techniques":["Metoda miareczkowa (Mohra)"],"computed":[],"activity":"Zawartość chlorku sodu\nZakres (0,25 − 60) %\nMetoda miareczkowa (Mohra)","reference":"PN-A-79011-7:1998","norm_bases":["PN-A-79011-7:1998"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Koncentraty spożywcze Zawartość chlorku sodu\nZakres (0,25 − 60) %\nMetoda miareczkowa (Mohra) PN-A-79011-7:1998 Koncentraty spozywcze Zawartosc chlorku sodu\nZakres (0,25 − 60) %\nMetoda miareczkowa (Mohra) PN-A-79011-7:1998","categories":["other"],"row_index":64,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sodium chloride content","parameters_en":[{"name":"Range","range":"(0,25 − 60) %"}],"search_en":"Food concentrates Sodium chloride content Titrimetric method (Mohr) Range PN-A-79011-7:1998","technique_en":"Titrimetric method (Mohr)","test_object_en":"Food concentrates","parameters_zh":[{"name":"范围","range":"(0,25 − 60) %"}],"search_zh":"食品浓缩制品 氯化钠含量 滴定法（莫尔法） 范围 PN-A-79011-7:1998","test_object_zh":"食品浓缩制品","methodology_zh":"氯化钠含量","technique_zh":"滴定法（莫尔法）"},{"_id":"6a836a14af14b9c0e7b1ded4","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Koncentraty spożywcze","methodology":"Obecność zanieczyszczeń mechanicznych","parameters":[],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Obecność zanieczyszczeń mechanicznych\nMetoda wizualna","reference":"PN-A-79011-2:1998 pkt 2.4","norm_bases":["PN-A-79011-2:1998 pkt 2.4"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Koncentraty spożywcze Obecność zanieczyszczeń mechanicznych\nMetoda wizualna PN-A-79011-2:1998 pkt 2.4 Koncentraty spozywcze Obecnosc zanieczyszczen mechanicznych\nMetoda wizualna PN-A-79011-2:1998 pkt 2.4","categories":["other"],"row_index":65,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of mechanical impurities","search_en":"Food concentrates Presence of mechanical impurities Visual method PN-A-79011-2:1998 pkt 2.4","technique_en":"Visual method","test_object_en":"Food concentrates","search_zh":"食品浓缩制品 目视法 PN-A-79011-2:1998 pkt 2.4","technique_zh":"目视法","test_object_zh":"食品浓缩制品"},{"_id":"6a836a14af14b9c0e7b1ded5","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Koncentraty spożywcze","methodology":"Obecność szkodników żywnościowych i ich pozostałości","parameters":[],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Obecność szkodników żywnościowych i ich pozostałości\nMetoda wizualna","reference":"PN-A-79011-2:1998 pkt 2.5","norm_bases":["PN-A-79011-2:1998 pkt 2.5"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Koncentraty spożywcze Obecność szkodników żywnościowych i ich pozostałości\nMetoda wizualna PN-A-79011-2:1998 pkt 2.5 Koncentraty spozywcze Obecnosc szkodnikow zywnosciowych i ich pozostalosci\nMetoda wizualna PN-A-79011-2:1998 pkt 2.5","categories":["food"],"row_index":66,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of food pests and their residues","search_en":"Food concentrates Presence of food pests and their residues Visual method PN-A-79011-2:1998 pkt 2.5","technique_en":"Visual method","test_object_en":"Food concentrates","search_zh":"食品浓缩制品 目视法 PN-A-79011-2:1998 pkt 2.5","technique_zh":"目视法","test_object_zh":"食品浓缩制品"},{"_id":"6a836a14af14b9c0e7b1ded6","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Wyroby i półprodukty cukiernicze","methodology":"Kwasowość","parameters":[{"name":"Zakres","range":"(0,2 - 8,0) stopnie normalne"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Kwasowość\nZakres (0,2 - 8,0) stopnie normalne\nMetoda miareczkowa","reference":"PN-79/A-88024 pkt 2.2, 2.3","norm_bases":["PN-79/A-88024 pkt 2.2, 2.3"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby i półprodukty cukiernicze Kwasowość\nZakres (0,2 - 8,0) stopnie normalne\nMetoda miareczkowa PN-79/A-88024 pkt 2.2, 2.3 Wyroby i polprodukty cukiernicze Kwasowosc\nZakres (0,2 - 8,0) stopnie normalne\nMetoda miareczkowa PN-79/A-88024 pkt 2.2, 2.3","categories":["food"],"row_index":67,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Acidity","parameters_en":[{"name":"Range","range":"(0,2 - 8,0) stopnie normalne"}],"search_en":"Confectionery products and semi-finished products Acidity Titrimetric method Range PN-79/A-88024 pkt 2.2, 2.3","technique_en":"Titrimetric method","test_object_en":"Confectionery products and semi-finished products","methodology_zh":"酸度","parameters_zh":[{"name":"范围","range":"(0,2 - 8,0) stopnie normalne"}],"search_zh":"糖果制品与半成品 酸度 滴定法 范围 PN-79/A-88024 pkt 2.2, 2.3","technique_zh":"滴定法","test_object_zh":"糖果制品与半成品"},{"_id":"6a836a14af14b9c0e7b1ded7","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Wyroby i półprodukty cukiernicze","methodology":"Liczba kwasowa wyekstrahowanego tłuszczu","parameters":[{"name":"Zakres","range":"(0,1 - 8,0) mgKOH/1g tł."}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Liczba kwasowa wyekstrahowanego tłuszczu\nZakres (0,1 - 8,0) mgKOH/1g tł.\nMetoda miareczkowa","reference":"PN-79/A-88024 pkt 2.5","norm_bases":["PN-79/A-88024 pkt 2.5"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby i półprodukty cukiernicze Liczba kwasowa wyekstrahowanego tłuszczu\nZakres (0,1 - 8,0) mgKOH/1g tł.\nMetoda miareczkowa PN-79/A-88024 pkt 2.5 Wyroby i polprodukty cukiernicze Liczba kwasowa wyekstrahowanego tluszczu\nZakres (0,1 - 8,0) mgKOH/1g tl.\nMetoda miareczkowa PN-79/A-88024 pkt 2.5","categories":["food"],"row_index":68,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Acid value of the extracted fat","parameters_en":[{"name":"Range","range":"(0,1 - 8,0) mgKOH/1g tł."}],"search_en":"Confectionery products and semi-finished products Acid value of the extracted fat Titrimetric method Range PN-79/A-88024 pkt 2.5","technique_en":"Titrimetric method","test_object_en":"Confectionery products and semi-finished products","parameters_zh":[{"name":"范围","range":"(0,1 - 8,0) mgKOH/1g tł."}],"search_zh":"糖果制品与半成品 滴定法 范围 PN-79/A-88024 pkt 2.5","technique_zh":"滴定法","test_object_zh":"糖果制品与半成品"},{"_id":"6a836a14af14b9c0e7b1ded8","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Wyroby i półprodukty cukiernicze","methodology":"Liczba nadtlenkowa wyekstrahowanego tłuszczu","parameters":[{"name":"Zakres","range":"( 0,1- 8,0) meqO2/kg"},{"name":"Zakres","range":"(0,05 – 4,0) mmolO2/kg"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Liczba nadtlenkowa wyekstrahowanego tłuszczu\nZakres:\nZakres ( 0,1- 8,0) meqO2/kg\nZakres (0,05 – 4,0) mmolO2/kg\nMetoda miareczkowa","reference":"PN-EN ISO 3960:2017-03","norm_bases":["PN-EN ISO 3960:2017-03"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby i półprodukty cukiernicze Liczba nadtlenkowa wyekstrahowanego tłuszczu\nZakres:\nZakres ( 0,1- 8,0) meqO2/kg\nZakres (0,05 – 4,0) mmolO2/kg\nMetoda miareczkowa PN-EN ISO 3960:2017-03 Wyroby i polprodukty cukiernicze Liczba nadtlenkowa wyekstrahowanego tluszczu\nZakres:\nZakres ( 0,1- 8,0) meqO2/kg\nZakres (0,05 – 4,0) mmolO2/kg\nMetoda miareczkowa PN-EN ISO 3960:2017-03","categories":["food"],"row_index":69,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Peroxide value of extracted fat","parameters_en":[{"name":"Range","range":"( 0,1- 8,0) meqO2/kg"},{"name":"Range","range":"(0,05 – 4,0) mmolO2/kg"}],"search_en":"Confectionery products and semi-finished products Peroxide value of extracted fat Titrimetric method Range Range PN-EN ISO 3960:2017-03","technique_en":"Titrimetric method","test_object_en":"Confectionery products and semi-finished products","parameters_zh":[{"name":"范围","range":"( 0,1- 8,0) meqO2/kg"},{"name":"范围","range":"(0,05 – 4,0) mmolO2/kg"}],"search_zh":"糖果制品与半成品 滴定法 范围 范围 PN-EN ISO 3960:2017-03","technique_zh":"滴定法","test_object_zh":"糖果制品与半成品"},{"_id":"6a836a14af14b9c0e7b1ded9","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Wyroby i półprodukty cukiernicze","methodology":"Zawartość tłuszczu/ Zawartość tłuszczu w przeliczeniu na suchą masę","parameters":[{"name":"Zakres","range":"(0,20 – 45,3)%"}],"technique":"Analiza wagowa za pomocą hydrolizy i ekstrakcji wspomaganej mikrofalami (MAHE)","techniques":["Analiza wagowa za pomocą hydrolizy i ekstrakcji wspomaganej mikrofalami (MAHE)"],"computed":[],"activity":"Zawartość tłuszczu/ Zawartość tłuszczu w przeliczeniu na suchą masę\nZakres (0,20 – 45,3)%\nAnaliza wagowa za pomocą hydrolizy i ekstrakcji wspomaganej mikrofalami (MAHE)","reference":"UNI 11949:2024","norm_bases":["UNI 11949:2024"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby i półprodukty cukiernicze Zawartość tłuszczu/ Zawartość tłuszczu w przeliczeniu na suchą masę\nZakres (0,20 – 45,3)%\nAnaliza wagowa za pomocą hydrolizy i ekstrakcji wspomaganej mikrofalami (MAHE) UNI 11949:2024 Wyroby i polprodukty cukiernicze Zawartosc tluszczu/ Zawartosc tluszczu w przeliczeniu na sucha mase\nZakres (0,20 – 45,3)%\nAnaliza wagowa za pomoca hydrolizy i ekstrakcji wspomaganej mikrofalami (MAHE) UNI 11949:2024","categories":["food"],"row_index":70,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fat content/ Fat content expressed on dry matter basis","parameters_en":[{"name":"Range","range":"(0,20 – 45,3)%"}],"search_en":"Confectionery products and semi-finished products Fat content/ Fat content expressed on dry matter basis Gravimetric analysis by microwave-assisted hydrolysis and extraction (MAHE) Range UNI 11949:2024","technique_en":"Gravimetric analysis by microwave-assisted hydrolysis and extraction (MAHE)","test_object_en":"Confectionery products and semi-finished products","parameters_zh":[{"name":"范围","range":"(0,20 – 45,3)%"}],"search_zh":"糖果制品与半成品 范围 UNI 11949:2024","test_object_zh":"糖果制品与半成品"},{"_id":"6a836a14af14b9c0e7b1deda","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Pieczywo i półprodukty piekarnicze","methodology":"Kwasowość","parameters":[{"name":"Zakres","range":"(0,2 – 7)°"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Kwasowość\nZakres (0,2 – 7)°\nMetoda miareczkowa","reference":"PN-A-74108:1996 pkt 3.4.4.","norm_bases":["PN-A-74108:1996 pkt 3.4.4."],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pieczywo i półprodukty piekarnicze Kwasowość\nZakres (0,2 – 7)°\nMetoda miareczkowa PN-A-74108:1996 pkt 3.4.4. Pieczywo i polprodukty piekarnicze Kwasowosc\nZakres (0,2 – 7)°\nMetoda miareczkowa PN-A-74108:1996 pkt 3.4.4.","categories":["other"],"row_index":71,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Acidity","parameters_en":[{"name":"Range","range":"(0,2 – 7)°"}],"search_en":"Bread and bakery semi-products Acidity Titrimetric method Range PN-A-74108:1996 pkt 3.4.4.","technique_en":"Titrimetric method","test_object_en":"Bread and bakery semi-products","methodology_zh":"酸度","parameters_zh":[{"name":"范围","range":"(0,2 – 7)°"}],"search_zh":"酸度 滴定法 范围 PN-A-74108:1996 pkt 3.4.4.","technique_zh":"滴定法"},{"_id":"6a836a14af14b9c0e7b1dedb","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Pieczywo","methodology":"Poziom jakości:","parameters":[{"name":"wygląd zewnętrzny"},{"name":"skórka (barwa, grubość, pozostałe cechy)"},{"name":"miękisz (elastyczność, porowatość pozostałe cechy)"},{"name":"zapach"},{"name":"smak"},{"name":"poziom jakości pieczywa","range":"(1- 4)"}],"technique":"Metoda punktowa","techniques":["Metoda punktowa"],"computed":[],"activity":"Poziom jakości:\nZakres:\nwygląd zewnętrzny\nskórka (barwa, grubość, pozostałe cechy)\nmiękisz (elastyczność, porowatość pozostałe cechy)\nzapach\nsmak\npoziom jakości pieczywa (1- 4)\nMetoda punktowa","reference":"PN-A-74108:1996 pkt. 4","norm_bases":["PN-A-74108:1996 pkt. 4"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pieczywo Poziom jakości:\nZakres:\nwygląd zewnętrzny\nskórka (barwa, grubość, pozostałe cechy)\nmiękisz (elastyczność, porowatość pozostałe cechy)\nzapach\nsmak\npoziom jakości pieczywa (1- 4)\nMetoda punktowa PN-A-74108:1996 pkt. 4 Pieczywo Poziom jakosci:\nZakres:\nwyglad zewnetrzny\nskorka (barwa, grubosc, pozostale cechy)\nmiekisz (elastycznosc, porowatosc pozostale cechy)\nzapach\nsmak\npoziom jakosci pieczywa (1- 4)\nMetoda punktowa PN-A-74108:1996 pkt. 4","categories":["other"],"row_index":72,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Quality level:","parameters_en":[{"name":"external appearance"},{"name":"skin (colour, thickness, other characteristics)"},{"name":"crumb (elasticity, porosity other characteristics)"},{"name":"odour"},{"name":"taste"},{"name":"bread quality level","range":"(1- 4)"}],"search_en":"Bread Quality level: Point method external appearance skin (colour, thickness, other characteristics) crumb (elasticity, porosity other characteristics) odour taste bread quality level PN-A-74108:1996 pkt. 4","technique_en":"Point method","test_object_en":"Bread","search_zh":"面包 点测法 PN-A-74108:1996 pkt. 4","technique_zh":"点测法","test_object_zh":"面包"},{"_id":"6a836a14af14b9c0e7b1dedc","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Smażone przekąski","methodology":"Zawartość chlorku sodu","parameters":[{"name":"Zakres","range":"(0,2- 5,0)%"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość chlorku sodu\nZakres (0,2- 5,0)%\nMetoda miareczkowa","reference":"PN-78/A-74702 pkt 2.14","norm_bases":["PN-78/A-74702 pkt 2.14"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Smażone przekąski Zawartość chlorku sodu\nZakres (0,2- 5,0)%\nMetoda miareczkowa PN-78/A-74702 pkt 2.14 Smazone przekaski Zawartosc chlorku sodu\nZakres (0,2- 5,0)%\nMetoda miareczkowa PN-78/A-74702 pkt 2.14","categories":["other"],"row_index":73,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sodium chloride content","parameters_en":[{"name":"Range","range":"(0,2- 5,0)%"}],"search_en":"Fried snacks Sodium chloride content Titrimetric method Range PN-78/A-74702 pkt 2.14","technique_en":"Titrimetric method","test_object_en":"Fried snacks","parameters_zh":[{"name":"范围","range":"(0,2- 5,0)%"}],"search_zh":"氯化钠含量 滴定法 范围 PN-78/A-74702 pkt 2.14","technique_zh":"滴定法","methodology_zh":"氯化钠含量"},{"_id":"6a836a14af14b9c0e7b1dedd","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Smażone przekąski","methodology":"Liczba kwasowa wyekstrahowanego tłuszczu","parameters":[{"name":"Zakres","range":"(0,03 – 5,00) mgKOH/1g tł."}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Liczba kwasowa wyekstrahowanego tłuszczu\nZakres (0,03 – 5,00) mgKOH/1g tł.\nMetoda miareczkowa","reference":"PN-A-74780:1996 pkt 5.3.6","norm_bases":["PN-A-74780:1996 pkt 5.3.6"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Smażone przekąski Liczba kwasowa wyekstrahowanego tłuszczu\nZakres (0,03 – 5,00) mgKOH/1g tł.\nMetoda miareczkowa PN-A-74780:1996 pkt 5.3.6 Smazone przekaski Liczba kwasowa wyekstrahowanego tluszczu\nZakres (0,03 – 5,00) mgKOH/1g tl.\nMetoda miareczkowa PN-A-74780:1996 pkt 5.3.6","categories":["other"],"row_index":74,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Acid value of the extracted fat","parameters_en":[{"name":"Range","range":"(0,03 – 5,00) mgKOH/1g tł."}],"search_en":"Fried snacks Acid value of the extracted fat Titrimetric method Range PN-A-74780:1996 pkt 5.3.6","technique_en":"Titrimetric method","test_object_en":"Fried snacks","parameters_zh":[{"name":"范围","range":"(0,03 – 5,00) mgKOH/1g tł."}],"search_zh":"滴定法 范围 PN-A-74780:1996 pkt 5.3.6","technique_zh":"滴定法"},{"_id":"6a836a14af14b9c0e7b1dede","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Smażone przekąski","methodology":"Liczba nadtlenkowa wyekstrahowanego tłuszczu / (Liczba Lea)","parameters":[{"name":"Zakres","range":"(0,05 – 15,0) mmolO2/kg"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Liczba nadtlenkowa wyekstrahowanego tłuszczu / (Liczba Lea)\nZakres (0,05 – 15,0) mmolO2/kg\nMetoda miareczkowa","reference":"PN-A-74780:1996 pkt 5.3.5","norm_bases":["PN-A-74780:1996 pkt 5.3.5"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Smażone przekąski Liczba nadtlenkowa wyekstrahowanego tłuszczu / (Liczba Lea)\nZakres (0,05 – 15,0) mmolO2/kg\nMetoda miareczkowa PN-A-74780:1996 pkt 5.3.5 Smazone przekaski Liczba nadtlenkowa wyekstrahowanego tluszczu / (Liczba Lea)\nZakres (0,05 – 15,0) mmolO2/kg\nMetoda miareczkowa PN-A-74780:1996 pkt 5.3.5","categories":["other"],"row_index":75,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Peroxide value of extracted fat / (Lea value)","parameters_en":[{"name":"Range","range":"(0,05 – 15,0) mmolO2/kg"}],"search_en":"Fried snacks Peroxide value of extracted fat / (Lea value) Titrimetric method Range PN-A-74780:1996 pkt 5.3.5","technique_en":"Titrimetric method","test_object_en":"Fried snacks","parameters_zh":[{"name":"范围","range":"(0,05 – 15,0) mmolO2/kg"}],"search_zh":"滴定法 范围 PN-A-74780:1996 pkt 5.3.5","technique_zh":"滴定法"},{"_id":"6a836a14af14b9c0e7b1dedf","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Ryby i przetwory rybne","methodology":"Zawartość soli kuchennej","parameters":[{"name":"Zakres","range":"(0,25 − 5,0) %"}],"technique":"Metoda miareczkowa (Mohra)","techniques":["Metoda miareczkowa (Mohra)"],"computed":[],"activity":"Zawartość soli kuchennej\nZakres (0,25 − 5,0) %\nMetoda miareczkowa (Mohra)","reference":"PN-74/A-86739","norm_bases":["PN-74/A-86739"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ryby i przetwory rybne Zawartość soli kuchennej\nZakres (0,25 − 5,0) %\nMetoda miareczkowa (Mohra) PN-74/A-86739 Ryby i przetwory rybne Zawartosc soli kuchennej\nZakres (0,25 − 5,0) %\nMetoda miareczkowa (Mohra) PN-74/A-86739","categories":["other"],"row_index":76,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Table salt content","parameters_en":[{"name":"Range","range":"(0,25 − 5,0) %"}],"search_en":"Fish and fish products Table salt content Titrimetric method (Mohr) Range PN-74/A-86739","technique_en":"Titrimetric method (Mohr)","test_object_en":"Fish and fish products","parameters_zh":[{"name":"范围","range":"(0,25 − 5,0) %"}],"search_zh":"鱼与鱼制品 食盐含量 滴定法（莫尔法） 范围 PN-74/A-86739","test_object_zh":"鱼与鱼制品","methodology_zh":"食盐含量","technique_zh":"滴定法（莫尔法）"},{"_id":"6a836a14af14b9c0e7b1dee0","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Ryby i przetwory rybne","methodology":"Kwasowość ogólna","parameters":[{"name":"Zakres","range":"(0,2 − 5,0) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Kwasowość ogólna\nZakres (0,2 − 5,0) %\nMetoda miareczkowa","reference":"PN-74/A-86746","norm_bases":["PN-74/A-86746"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ryby i przetwory rybne Kwasowość ogólna\nZakres (0,2 − 5,0) %\nMetoda miareczkowa PN-74/A-86746 Ryby i przetwory rybne Kwasowosc ogolna\nZakres (0,2 − 5,0) %\nMetoda miareczkowa PN-74/A-86746","categories":["other"],"row_index":77,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total acidity","parameters_en":[{"name":"Range","range":"(0,2 − 5,0) %"}],"search_en":"Fish and fish products Total acidity Titrimetric method Range PN-74/A-86746","technique_en":"Titrimetric method","test_object_en":"Fish and fish products","parameters_zh":[{"name":"范围","range":"(0,2 − 5,0) %"}],"search_zh":"鱼与鱼制品 总酸度 滴定法 范围 PN-74/A-86746","technique_zh":"滴定法","test_object_zh":"鱼与鱼制品","methodology_zh":"总酸度"},{"_id":"6a836a14af14b9c0e7b1dee1","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Sery","methodology":"Zawartość soli kuchennej","parameters":[{"name":"Zakres","range":"(0,25 − 5,0) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość soli kuchennej\nZakres (0,25 − 5,0) %\nMetoda miareczkowa","reference":"PN-73/A-86232 pkt 3.5","norm_bases":["PN-73/A-86232 pkt 3.5"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Sery Zawartość soli kuchennej\nZakres (0,25 − 5,0) %\nMetoda miareczkowa PN-73/A-86232 pkt 3.5 Sery Zawartosc soli kuchennej\nZakres (0,25 − 5,0) %\nMetoda miareczkowa PN-73/A-86232 pkt 3.5","categories":["other"],"row_index":78,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Table salt content","parameters_en":[{"name":"Range","range":"(0,25 − 5,0) %"}],"search_en":"Cheeses Table salt content Titrimetric method Range PN-73/A-86232 pkt 3.5","technique_en":"Titrimetric method","test_object_en":"Cheeses","parameters_zh":[{"name":"范围","range":"(0,25 − 5,0) %"}],"search_zh":"干酪 食盐含量 滴定法 范围 PN-73/A-86232 pkt 3.5","technique_zh":"滴定法","methodology_zh":"食盐含量","test_object_zh":"干酪"},{"_id":"6a836a14af14b9c0e7b1dee2","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Sery","methodology":"Kwasowość ogólna","parameters":[{"name":"Zakres","range":"(3,0 − 150,0) ºSH"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Kwasowość ogólna\nZakres (3,0 − 150,0) ºSH\nMetoda miareczkowa","reference":"PN-73/A-86232 pkt 3.6","norm_bases":["PN-73/A-86232 pkt 3.6"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Sery Kwasowość ogólna\nZakres (3,0 − 150,0) ºSH\nMetoda miareczkowa PN-73/A-86232 pkt 3.6 Sery Kwasowosc ogolna\nZakres (3,0 − 150,0) ºSH\nMetoda miareczkowa PN-73/A-86232 pkt 3.6","categories":["other"],"row_index":79,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total acidity","parameters_en":[{"name":"Range","range":"(3,0 − 150,0) ºSH"}],"search_en":"Cheeses Total acidity Titrimetric method Range PN-73/A-86232 pkt 3.6","technique_en":"Titrimetric method","test_object_en":"Cheeses","parameters_zh":[{"name":"范围","range":"(3,0 − 150,0) ºSH"}],"search_zh":"干酪 总酸度 滴定法 范围 PN-73/A-86232 pkt 3.6","technique_zh":"滴定法","methodology_zh":"总酸度","test_object_zh":"干酪"},{"_id":"6a836a14af14b9c0e7b1dee3","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Wyroby garmażeryjne","methodology":"Zawartość soli kuchennej","parameters":[{"name":"Zakres","range":"(0,05 − 7,0) %"}],"technique":"Metoda miareczkowa (Mohra)","techniques":["Metoda miareczkowa (Mohra)"],"computed":[],"activity":"Zawartość soli kuchennej\nZakres (0,05 − 7,0) %\nMetoda miareczkowa (Mohra)","reference":"PN-85/A-82100 pkt 2.7","norm_bases":["PN-85/A-82100 pkt 2.7"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby garmażeryjne Zawartość soli kuchennej\nZakres (0,05 − 7,0) %\nMetoda miareczkowa (Mohra) PN-85/A-82100 pkt 2.7 Wyroby garmazeryjne Zawartosc soli kuchennej\nZakres (0,05 − 7,0) %\nMetoda miareczkowa (Mohra) PN-85/A-82100 pkt 2.7","categories":["other"],"row_index":80,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Table salt content","parameters_en":[{"name":"Range","range":"(0,05 − 7,0) %"}],"search_en":"Delicatessen products Table salt content Titrimetric method (Mohr) Range PN-85/A-82100 pkt 2.7","technique_en":"Titrimetric method (Mohr)","test_object_en":"Delicatessen products","parameters_zh":[{"name":"范围","range":"(0,05 − 7,0) %"}],"search_zh":"熟食制品 食盐含量 滴定法（莫尔法） 范围 PN-85/A-82100 pkt 2.7","test_object_zh":"熟食制品","methodology_zh":"食盐含量","technique_zh":"滴定法（莫尔法）"},{"_id":"6a836a14af14b9c0e7b1dee4","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Wyroby garmażeryjne","methodology":"Zawartość całkowitego dwutlenku siarki","parameters":[{"name":"Zakres","range":"(5,0 - 500) mg/kg"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość całkowitego dwutlenku siarki\nZakres (5,0 - 500) mg/kg\nMetoda miareczkowa","reference":"PN-90/A-75101/23 pkt 3+Az2:2002","norm_bases":["PN-90/A-75101/23 pkt 3+Az2:2002"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby garmażeryjne Zawartość całkowitego dwutlenku siarki\nZakres (5,0 - 500) mg/kg\nMetoda miareczkowa PN-90/A-75101/23 pkt 3+Az2:2002 Wyroby garmazeryjne Zawartosc calkowitego dwutlenku siarki\nZakres (5,0 - 500) mg/kg\nMetoda miareczkowa PN-90/A-75101/23 pkt 3+Az2:2002","categories":["other"],"row_index":81,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total sulphur dioxide content","parameters_en":[{"name":"Range","range":"(5,0 - 500) mg/kg"}],"search_en":"Delicatessen products Total sulphur dioxide content Titrimetric method Range PN-90/A-75101/23 pkt 3+Az2:2002","technique_en":"Titrimetric method","test_object_en":"Delicatessen products","parameters_zh":[{"name":"范围","range":"(5,0 - 500) mg/kg"}],"search_zh":"熟食制品 滴定法 范围 PN-90/A-75101/23 pkt 3+Az2:2002","technique_zh":"滴定法","test_object_zh":"熟食制品"},{"_id":"6a836a14af14b9c0e7b1dee5","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Wyroby garmażeryjne","methodology":"Zawartość tłuszczu","parameters":[{"name":"Zakres","range":"(0,40 – 22,4)%"}],"technique":"Analiza wagowa za pomocą hydrolizy i ekstrakcji wspomaganej mikrofalami (MAHE)","techniques":["Analiza wagowa za pomocą hydrolizy i ekstrakcji wspomaganej mikrofalami (MAHE)"],"computed":[],"activity":"Zawartość tłuszczu\nZakres (0,40 – 22,4)%\nAnaliza wagowa za pomocą hydrolizy i ekstrakcji wspomaganej mikrofalami (MAHE)","reference":"UNI 11949:2024","norm_bases":["UNI 11949:2024"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby garmażeryjne Zawartość tłuszczu\nZakres (0,40 – 22,4)%\nAnaliza wagowa za pomocą hydrolizy i ekstrakcji wspomaganej mikrofalami (MAHE) UNI 11949:2024 Wyroby garmazeryjne Zawartosc tluszczu\nZakres (0,40 – 22,4)%\nAnaliza wagowa za pomoca hydrolizy i ekstrakcji wspomaganej mikrofalami (MAHE) UNI 11949:2024","categories":["other"],"row_index":82,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fat content","parameters_en":[{"name":"Range","range":"(0,40 – 22,4)%"}],"search_en":"Delicatessen products Fat content Gravimetric analysis by microwave-assisted hydrolysis and extraction (MAHE) Range UNI 11949:2024","technique_en":"Gravimetric analysis by microwave-assisted hydrolysis and extraction (MAHE)","test_object_en":"Delicatessen products","methodology_zh":"脂肪含量","parameters_zh":[{"name":"范围","range":"(0,40 – 22,4)%"}],"search_zh":"熟食制品 脂肪含量 范围 UNI 11949:2024","test_object_zh":"熟食制品"},{"_id":"6a836a14af14b9c0e7b1dee6","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Napoje bezalkoholowe","methodology":"Zawartość ekstraktu ogólnego","parameters":[{"name":"Zakres","range":"(0,10 − 17,0) %"}],"technique":"Metoda refraktometryczna","techniques":["Metoda refraktometryczna"],"computed":[],"activity":"Zawartość ekstraktu ogólnego\nZakres (0,10 − 17,0) %\nMetoda refraktometryczna","reference":"PN-85/A-79033 pkt 3.6.1","norm_bases":["PN-85/A-79033 pkt 3.6.1"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Napoje bezalkoholowe Zawartość ekstraktu ogólnego\nZakres (0,10 − 17,0) %\nMetoda refraktometryczna PN-85/A-79033 pkt 3.6.1 Napoje bezalkoholowe Zawartosc ekstraktu ogolnego\nZakres (0,10 − 17,0) %\nMetoda refraktometryczna PN-85/A-79033 pkt 3.6.1","categories":["food"],"row_index":83,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total extract content","parameters_en":[{"name":"Range","range":"(0,10 − 17,0) %"}],"search_en":"Non-alcoholic beverages Total extract content Refractometric method Range PN-85/A-79033 pkt 3.6.1","technique_en":"Refractometric method","test_object_en":"Non-alcoholic beverages","parameters_zh":[{"name":"范围","range":"(0,10 − 17,0) %"}],"search_zh":"无酒精饮料 总浸出物含量 折射法 范围 PN-85/A-79033 pkt 3.6.1","technique_zh":"折射法","test_object_zh":"无酒精饮料","methodology_zh":"总浸出物含量"},{"_id":"6a836a14af14b9c0e7b1dee7","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Napoje bezalkoholowe","methodology":"Kwasowość w przeliczeniu na kwas cytrynowy","parameters":[{"name":"Zakres","range":"(0,1 − 1,0) g/100 ml"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Kwasowość w przeliczeniu na kwas cytrynowy\nZakres (0,1 − 1,0) g/100 ml\nMetoda miareczkowa","reference":"PN-85/A-79033 pkt 3.8.1, 3.8.2","norm_bases":["PN-85/A-79033 pkt 3.8.1, 3.8.2"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Napoje bezalkoholowe Kwasowość w przeliczeniu na kwas cytrynowy\nZakres (0,1 − 1,0) g/100 ml\nMetoda miareczkowa PN-85/A-79033 pkt 3.8.1, 3.8.2 Napoje bezalkoholowe Kwasowosc w przeliczeniu na kwas cytrynowy\nZakres (0,1 − 1,0) g/100 ml\nMetoda miareczkowa PN-85/A-79033 pkt 3.8.1, 3.8.2","categories":["food"],"row_index":84,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Acidity expressed as citric acid","parameters_en":[{"name":"Range","range":"(0,1 − 1,0) g/100 ml"}],"search_en":"Non-alcoholic beverages Acidity expressed as citric acid Titrimetric method Range PN-85/A-79033 pkt 3.8.1, 3.8.2","technique_en":"Titrimetric method","test_object_en":"Non-alcoholic beverages","parameters_zh":[{"name":"范围","range":"(0,1 − 1,0) g/100 ml"}],"search_zh":"无酒精饮料 滴定法 范围 PN-85/A-79033 pkt 3.8.1, 3.8.2","technique_zh":"滴定法","test_object_zh":"无酒精饮料"},{"_id":"6a836a14af14b9c0e7b1dee8","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Napoje bezalkoholowe","methodology":"Zawartość kwasów lotnych w przeliczeniu na kwas octowy","parameters":[{"name":"Zakres","range":"(0,001 – 5) g/100 cm3"}],"technique":"Metoda destylacyjno-miareczkowa","techniques":["Metoda destylacyjno-miareczkowa"],"computed":[],"activity":"Zawartość kwasów lotnych w przeliczeniu na kwas octowy\nZakres (0,001 – 5) g/100 cm3\nMetoda destylacyjno-miareczkowa","reference":"PN-85/A-79033 pkt 3.9","norm_bases":["PN-85/A-79033 pkt 3.9"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Napoje bezalkoholowe Zawartość kwasów lotnych w przeliczeniu na kwas octowy\nZakres (0,001 – 5) g/100 cm3\nMetoda destylacyjno-miareczkowa PN-85/A-79033 pkt 3.9 Napoje bezalkoholowe Zawartosc kwasow lotnych w przeliczeniu na kwas octowy\nZakres (0,001 – 5) g/100 cm3\nMetoda destylacyjno-miareczkowa PN-85/A-79033 pkt 3.9","categories":["food"],"row_index":85,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Volatile acid content calculated as acetic acid","parameters_en":[{"name":"Range","range":"(0,001 – 5) g/100 cm3"}],"search_en":"Non-alcoholic beverages Volatile acid content calculated as acetic acid Distillation-titrimetric method Range PN-85/A-79033 pkt 3.9","technique_en":"Distillation-titrimetric method","test_object_en":"Non-alcoholic beverages","parameters_zh":[{"name":"范围","range":"(0,001 – 5) g/100 cm3"}],"search_zh":"无酒精饮料 蒸馏-滴定法 范围 PN-85/A-79033 pkt 3.9","test_object_zh":"无酒精饮料","technique_zh":"蒸馏-滴定法"},{"_id":"6a836a14af14b9c0e7b1dee9","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Koncentraty spożywcze, Mięso i produkty mięsne, Mleko i produkty mleczne, Ryby i przetwory rybne, Słodycze i wyroby cukiernicze, Pieczywo i półprodukty piekarnicze, Zboża i przetwory zbożowe, Żywność mrożona, Wyroby garmażeryjne, Napoje bezalkoholowe, (gazowane, niegazowane, soki, syropy, nektary), Owoce i warzywa, przetwory owocowe i warzywne oraz warzywno-mięsne, Oleje i tłuszcze roślinne i zwierzęce, Środki specjalnego przeznaczenia żywieniowego","methodology":"Wartość energetyczna kcal/100g lub kJ/100g (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wartość energetyczna kcal/100g lub kJ/100g (z obliczeń)","reference":"PN-A-82350:1996 pkt 3.6.8.4","norm_bases":["PN-A-82350:1996 pkt 3.6.8.4"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Koncentraty spożywcze, Mięso i produkty mięsne, Mleko i produkty mleczne, Ryby i przetwory rybne, Słodycze i wyroby cukiernicze, Pieczywo i półprodukty piekarnicze, Zboża i przetwory zbożowe, Żywność mrożona, Wyroby garmażeryjne, Napoje bezalkoholowe, (gazowane, niegazowane, soki, syropy, nektary), Owoce i warzywa, przetwory owocowe i warzywne oraz warzywno-mięsne, Oleje i tłuszcze roślinne i zwierzęce, Środki specjalnego przeznaczenia żywieniowego Wartość energetyczna kcal/100g lub kJ/100g (z obliczeń) PN-A-82350:1996 pkt 3.6.8.4 Koncentraty spozywcze, Mieso i produkty miesne, Mleko i produkty mleczne, Ryby i przetwory rybne, Slodycze i wyroby cukiernicze, Pieczywo i polprodukty piekarnicze, Zboza i przetwory zbozowe, Zywnosc mrozona, Wyroby garmazeryjne, Napoje bezalkoholowe, (gazowane, niegazowane, soki, syropy, nektary), Owoce i warzywa, przetwory owocowe i warzywne oraz warzywno-miesne, Oleje i tluszcze roslinne i zwierzece, Srodki specjalnego przeznaczenia zywieniowego Wartosc energetyczna kcal/100g lub kJ/100g (z obliczen) PN-A-82350:1996 pkt 3.6.8.4","categories":["food","petro"],"row_index":86,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Energy value kcal/100g or kJ/100g (calculated)","search_en":"Food concentrates, Meat and meat products, Milk and dairy products, Fish and fish products, Sweets and confectionery, Bread and bakery semi-finished products, Cereals and cereal products, Frozen food, Delicatessen products, Non-alcoholic beverages, (carbonated, still, juices, syrups, nectars), Fruit and vegetables, fruit, vegetable and vegetable-meat preserves, Vegetable and animal oils and fats, Foodstuffs for particular nutritional uses Energy value kcal/100g or kJ/100g (calculated) PN-A-82350:1996 pkt 3.6.8.4","test_object_en":"Food concentrates, Meat and meat products, Milk and dairy products, Fish and fish products, Sweets and confectionery, Bread and bakery semi-finished products, Cereals and cereal products, Frozen food, Delicatessen products, Non-alcoholic beverages, (carbonated, still, juices, syrups, nectars), Fruit and vegetables, fruit, vegetable and vegetable-meat preserves, Vegetable and animal oils and fats, Foodstuffs for particular nutritional uses","search_zh":"食品浓缩制品，肉与肉制品，乳与乳制品，鱼与鱼制品，甜食与糖果制品，面包与烘焙半成品，谷物与谷物制品，冷冻食品，熟食制品，无酒精饮料（含气、不含气、果汁、糖浆、果蜜），水果与蔬菜、果蔬制品及蔬菜肉类制品，动植物油脂 PN-A-82350:1996 pkt 3.6.8.4","test_object_zh":"食品浓缩制品，肉与肉制品，乳与乳制品，鱼与鱼制品，甜食与糖果制品，面包与烘焙半成品，谷物与谷物制品，冷冻食品，熟食制品，无酒精饮料（含气、不含气、果汁、糖浆、果蜜），水果与蔬菜、果蔬制品及蔬菜肉类制品，动植物油脂"},{"_id":"6a836a14af14b9c0e7b1deea","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Koncentraty spożywcze, Mięso i produkty mięsne, Mleko i produkty mleczne, Ryby i przetwory rybne, Słodycze i wyroby cukiernicze, Pieczywo i półprodukty piekarnicze, Zboża i przetwory zbożowe, Żywność mrożona, Wyroby garmażeryjne, Napoje bezalkoholowe, (gazowane, niegazowane, soki, syropy, nektary), Owoce i warzywa, przetwory owocowe i warzywne oraz warzywno-mięsne, Oleje i tłuszcze roślinne i zwierzęce, Środki specjalnego przeznaczenia żywieniowego","methodology":"Wartość energetyczna kcal/100g lub kJ/100g (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wartość energetyczna kcal/100g lub kJ/100g (z obliczeń)","reference":"PN-A-79011-6:1998+Az1:2008 pkt 3.4","norm_bases":["PN-A-79011-6:1998+Az1:2008 pkt 3.4"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Koncentraty spożywcze, Mięso i produkty mięsne, Mleko i produkty mleczne, Ryby i przetwory rybne, Słodycze i wyroby cukiernicze, Pieczywo i półprodukty piekarnicze, Zboża i przetwory zbożowe, Żywność mrożona, Wyroby garmażeryjne, Napoje bezalkoholowe, (gazowane, niegazowane, soki, syropy, nektary), Owoce i warzywa, przetwory owocowe i warzywne oraz warzywno-mięsne, Oleje i tłuszcze roślinne i zwierzęce, Środki specjalnego przeznaczenia żywieniowego Wartość energetyczna kcal/100g lub kJ/100g (z obliczeń) PN-A-79011-6:1998+Az1:2008 pkt 3.4 Koncentraty spozywcze, Mieso i produkty miesne, Mleko i produkty mleczne, Ryby i przetwory rybne, Slodycze i wyroby cukiernicze, Pieczywo i polprodukty piekarnicze, Zboza i przetwory zbozowe, Zywnosc mrozona, Wyroby garmazeryjne, Napoje bezalkoholowe, (gazowane, niegazowane, soki, syropy, nektary), Owoce i warzywa, przetwory owocowe i warzywne oraz warzywno-miesne, Oleje i tluszcze roslinne i zwierzece, Srodki specjalnego przeznaczenia zywieniowego Wartosc energetyczna kcal/100g lub kJ/100g (z obliczen) PN-A-79011-6:1998+Az1:2008 pkt 3.4","categories":["food","petro"],"row_index":87,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Energy value kcal/100g or kJ/100g (calculated)","search_en":"Food concentrates, Meat and meat products, Milk and dairy products, Fish and fish products, Sweets and confectionery, Bread and bakery semi-finished products, Cereals and cereal products, Frozen food, Delicatessen products, Non-alcoholic beverages, (carbonated, still, juices, syrups, nectars), Fruit and vegetables, fruit, vegetable and vegetable-meat preserves, Vegetable and animal oils and fats, Foodstuffs for particular nutritional uses Energy value kcal/100g or kJ/100g (calculated) PN-A-79011-6:1998+Az1:2008 pkt 3.4","test_object_en":"Food concentrates, Meat and meat products, Milk and dairy products, Fish and fish products, Sweets and confectionery, Bread and bakery semi-finished products, Cereals and cereal products, Frozen food, Delicatessen products, Non-alcoholic beverages, (carbonated, still, juices, syrups, nectars), Fruit and vegetables, fruit, vegetable and vegetable-meat preserves, Vegetable and animal oils and fats, Foodstuffs for particular nutritional uses","search_zh":"食品浓缩制品，肉与肉制品，乳与乳制品，鱼与鱼制品，甜食与糖果制品，面包与烘焙半成品，谷物与谷物制品，冷冻食品，熟食制品，无酒精饮料（含气、不含气、果汁、糖浆、果蜜），水果与蔬菜、果蔬制品及蔬菜肉类制品，动植物油脂 PN-A-79011-6:1998+Az1:2008 pkt 3.4","test_object_zh":"食品浓缩制品，肉与肉制品，乳与乳制品，鱼与鱼制品，甜食与糖果制品，面包与烘焙半成品，谷物与谷物制品，冷冻食品，熟食制品，无酒精饮料（含气、不含气、果汁、糖浆、果蜜），水果与蔬菜、果蔬制品及蔬菜肉类制品，动植物油脂"},{"_id":"6a836a14af14b9c0e7b1deeb","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Koncentraty spożywcze, Mięso i produkty mięsne, Mleko i produkty mleczne, Ryby i przetwory rybne, Słodycze i wyroby cukiernicze, Pieczywo i półprodukty piekarnicze, Zboża i przetwory zbożowe, Żywność mrożona, Wyroby garmażeryjne, Napoje bezalkoholowe, (gazowane, niegazowane, soki, syropy, nektary), Owoce i warzywa, przetwory owocowe i warzywne oraz warzywno-mięsne, Oleje i tłuszcze roślinne i zwierzęce, Środki specjalnego przeznaczenia żywieniowego","methodology":"Wartość energetyczna kcal/100g lub kJ/100g (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wartość energetyczna kcal/100g lub kJ/100g (z obliczeń)","reference":"Rozporządzenie Parlamentu Europejskiego i Rady (UE) Nr 1169/2011 z dnia 25.10.2011r. Załącznik XIV","norm_bases":["Rozporządzenie Parlamentu Europejskiego i Rady (UE) Nr 1169/2011 z dnia 25.10.2011r. Załącznik XIV"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Koncentraty spożywcze, Mięso i produkty mięsne, Mleko i produkty mleczne, Ryby i przetwory rybne, Słodycze i wyroby cukiernicze, Pieczywo i półprodukty piekarnicze, Zboża i przetwory zbożowe, Żywność mrożona, Wyroby garmażeryjne, Napoje bezalkoholowe, (gazowane, niegazowane, soki, syropy, nektary), Owoce i warzywa, przetwory owocowe i warzywne oraz warzywno-mięsne, Oleje i tłuszcze roślinne i zwierzęce, Środki specjalnego przeznaczenia żywieniowego Wartość energetyczna kcal/100g lub kJ/100g (z obliczeń) Rozporządzenie Parlamentu Europejskiego i Rady (UE) Nr 1169/2011 z dnia 25.10.2011r. Załącznik XIV Koncentraty spozywcze, Mieso i produkty miesne, Mleko i produkty mleczne, Ryby i przetwory rybne, Slodycze i wyroby cukiernicze, Pieczywo i polprodukty piekarnicze, Zboza i przetwory zbozowe, Zywnosc mrozona, Wyroby garmazeryjne, Napoje bezalkoholowe, (gazowane, niegazowane, soki, syropy, nektary), Owoce i warzywa, przetwory owocowe i warzywne oraz warzywno-miesne, Oleje i tluszcze roslinne i zwierzece, Srodki specjalnego przeznaczenia zywieniowego Wartosc energetyczna kcal/100g lub kJ/100g (z obliczen) Rozporzadzenie Parlamentu Europejskiego i Rady (UE) Nr 1169/2011 z dnia 25.10.2011r. Zalacznik XIV","categories":["food","petro"],"row_index":88,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Energy value kcal/100g or kJ/100g (calculated)","search_en":"Food concentrates, Meat and meat products, Milk and dairy products, Fish and fish products, Sweets and confectionery, Bread and bakery semi-finished products, Cereals and cereal products, Frozen food, Delicatessen products, Non-alcoholic beverages, (carbonated, still, juices, syrups, nectars), Fruit and vegetables, fruit, vegetable and vegetable-meat preserves, Vegetable and animal oils and fats, Foodstuffs for particular nutritional uses Energy value kcal/100g or kJ/100g (calculated) Rozporządzenie Parlamentu Europejskiego i Rady (UE) Nr 1169/2011 z dnia 25.10.2011r. Załącznik XIV","test_object_en":"Food concentrates, Meat and meat products, Milk and dairy products, Fish and fish products, Sweets and confectionery, Bread and bakery semi-finished products, Cereals and cereal products, Frozen food, Delicatessen products, Non-alcoholic beverages, (carbonated, still, juices, syrups, nectars), Fruit and vegetables, fruit, vegetable and vegetable-meat preserves, Vegetable and animal oils and fats, Foodstuffs for particular nutritional uses","search_zh":"食品浓缩制品，肉与肉制品，乳与乳制品，鱼与鱼制品，甜食与糖果制品，面包与烘焙半成品，谷物与谷物制品，冷冻食品，熟食制品，无酒精饮料（含气、不含气、果汁、糖浆、果蜜），水果与蔬菜、果蔬制品及蔬菜肉类制品，动植物油脂 Rozporządzenie Parlamentu Europejskiego i Rady (UE) Nr 1169/2011 z dnia 25.10.2011r. Załącznik XIV","test_object_zh":"食品浓缩制品，肉与肉制品，乳与乳制品，鱼与鱼制品，甜食与糖果制品，面包与烘焙半成品，谷物与谷物制品，冷冻食品，熟食制品，无酒精饮料（含气、不含气、果汁、糖浆、果蜜），水果与蔬菜、果蔬制品及蔬菜肉类制品，动植物油脂"},{"_id":"6a836a14af14b9c0e7b1deec","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Koncentraty spożywcze, Mięso i produkty mięsne, Mleko i produkty mleczne, Ryby i przetwory rybne, Słodycze i wyroby cukiernicze, Pieczywo i półprodukty piekarnicze, Zboża i przetwory zbożowe, Żywność mrożona, Wyroby garmażeryjne, Napoje bezalkoholowe, (gazowane, niegazowane, soki, syropy, nektary), Owoce i warzywa, przetwory owocowe i warzywne oraz warzywno-mięsne, Oleje i tłuszcze roślinne i zwierzęce, Środki specjalnego przeznaczenia żywieniowego","methodology":"Zawartość węglowodanów [g/100g] (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość węglowodanów [g/100g] (z obliczeń)","reference":"PN-A-82350:1996 pkt 3.6.8.3","norm_bases":["PN-A-82350:1996 pkt 3.6.8.3"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Koncentraty spożywcze, Mięso i produkty mięsne, Mleko i produkty mleczne, Ryby i przetwory rybne, Słodycze i wyroby cukiernicze, Pieczywo i półprodukty piekarnicze, Zboża i przetwory zbożowe, Żywność mrożona, Wyroby garmażeryjne, Napoje bezalkoholowe, (gazowane, niegazowane, soki, syropy, nektary), Owoce i warzywa, przetwory owocowe i warzywne oraz warzywno-mięsne, Oleje i tłuszcze roślinne i zwierzęce, Środki specjalnego przeznaczenia żywieniowego Zawartość węglowodanów [g/100g] (z obliczeń) PN-A-82350:1996 pkt 3.6.8.3 Koncentraty spozywcze, Mieso i produkty miesne, Mleko i produkty mleczne, Ryby i przetwory rybne, Slodycze i wyroby cukiernicze, Pieczywo i polprodukty piekarnicze, Zboza i przetwory zbozowe, Zywnosc mrozona, Wyroby garmazeryjne, Napoje bezalkoholowe, (gazowane, niegazowane, soki, syropy, nektary), Owoce i warzywa, przetwory owocowe i warzywne oraz warzywno-miesne, Oleje i tluszcze roslinne i zwierzece, Srodki specjalnego przeznaczenia zywieniowego Zawartosc weglowodanow [g/100g] (z obliczen) PN-A-82350:1996 pkt 3.6.8.3","categories":["food","petro"],"row_index":89,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Carbohydrate content [g/100g] (calculated)","search_en":"Food concentrates, Meat and meat products, Milk and dairy products, Fish and fish products, Sweets and confectionery, Bread and bakery semi-finished products, Cereals and cereal products, Frozen food, Delicatessen products, Non-alcoholic beverages, (carbonated, still, juices, syrups, nectars), Fruit and vegetables, fruit, vegetable and vegetable-meat preserves, Vegetable and animal oils and fats, Foodstuffs for particular nutritional uses Carbohydrate content [g/100g] (calculated) PN-A-82350:1996 pkt 3.6.8.3","test_object_en":"Food concentrates, Meat and meat products, Milk and dairy products, Fish and fish products, Sweets and confectionery, Bread and bakery semi-finished products, Cereals and cereal products, Frozen food, Delicatessen products, Non-alcoholic beverages, (carbonated, still, juices, syrups, nectars), Fruit and vegetables, fruit, vegetable and vegetable-meat preserves, Vegetable and animal oils and fats, Foodstuffs for particular nutritional uses","search_zh":"食品浓缩制品，肉与肉制品，乳与乳制品，鱼与鱼制品，甜食与糖果制品，面包与烘焙半成品，谷物与谷物制品，冷冻食品，熟食制品，无酒精饮料（含气、不含气、果汁、糖浆、果蜜），水果与蔬菜、果蔬制品及蔬菜肉类制品，动植物油脂 PN-A-82350:1996 pkt 3.6.8.3","test_object_zh":"食品浓缩制品，肉与肉制品，乳与乳制品，鱼与鱼制品，甜食与糖果制品，面包与烘焙半成品，谷物与谷物制品，冷冻食品，熟食制品，无酒精饮料（含气、不含气、果汁、糖浆、果蜜），水果与蔬菜、果蔬制品及蔬菜肉类制品，动植物油脂"},{"_id":"6a836a14af14b9c0e7b1deed","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Koncentraty spożywcze, Mięso i produkty mięsne, Mleko i produkty mleczne, Ryby i przetwory rybne, Słodycze i wyroby cukiernicze, Pieczywo i półprodukty piekarnicze, Zboża i przetwory zbożowe, Żywność mrożona, Wyroby garmażeryjne, Napoje bezalkoholowe, (gazowane, niegazowane, soki, syropy, nektary), Owoce i warzywa, przetwory owocowe i warzywne oraz warzywno-mięsne, Oleje i tłuszcze roślinne i zwierzęce, Środki specjalnego przeznaczenia żywieniowego","methodology":"Zawartość węglowodanów [g/100g] (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość węglowodanów [g/100g] (z obliczeń)","reference":"PN-A-79011-6:1998+Az1:2008 pkt 3.3.5","norm_bases":["PN-A-79011-6:1998+Az1:2008 pkt 3.3.5"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Koncentraty spożywcze, Mięso i produkty mięsne, Mleko i produkty mleczne, Ryby i przetwory rybne, Słodycze i wyroby cukiernicze, Pieczywo i półprodukty piekarnicze, Zboża i przetwory zbożowe, Żywność mrożona, Wyroby garmażeryjne, Napoje bezalkoholowe, (gazowane, niegazowane, soki, syropy, nektary), Owoce i warzywa, przetwory owocowe i warzywne oraz warzywno-mięsne, Oleje i tłuszcze roślinne i zwierzęce, Środki specjalnego przeznaczenia żywieniowego Zawartość węglowodanów [g/100g] (z obliczeń) PN-A-79011-6:1998+Az1:2008 pkt 3.3.5 Koncentraty spozywcze, Mieso i produkty miesne, Mleko i produkty mleczne, Ryby i przetwory rybne, Slodycze i wyroby cukiernicze, Pieczywo i polprodukty piekarnicze, Zboza i przetwory zbozowe, Zywnosc mrozona, Wyroby garmazeryjne, Napoje bezalkoholowe, (gazowane, niegazowane, soki, syropy, nektary), Owoce i warzywa, przetwory owocowe i warzywne oraz warzywno-miesne, Oleje i tluszcze roslinne i zwierzece, Srodki specjalnego przeznaczenia zywieniowego Zawartosc weglowodanow [g/100g] (z obliczen) PN-A-79011-6:1998+Az1:2008 pkt 3.3.5","categories":["food","petro"],"row_index":90,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Carbohydrate content [g/100g] (calculated)","search_en":"Food concentrates, Meat and meat products, Milk and dairy products, Fish and fish products, Sweets and confectionery, Bread and bakery semi-finished products, Cereals and cereal products, Frozen food, Delicatessen products, Non-alcoholic beverages, (carbonated, still, juices, syrups, nectars), Fruit and vegetables, fruit, vegetable and vegetable-meat preserves, Vegetable and animal oils and fats, Foodstuffs for particular nutritional uses Carbohydrate content [g/100g] (calculated) PN-A-79011-6:1998+Az1:2008 pkt 3.3.5","test_object_en":"Food concentrates, Meat and meat products, Milk and dairy products, Fish and fish products, Sweets and confectionery, Bread and bakery semi-finished products, Cereals and cereal products, Frozen food, Delicatessen products, Non-alcoholic beverages, (carbonated, still, juices, syrups, nectars), Fruit and vegetables, fruit, vegetable and vegetable-meat preserves, Vegetable and animal oils and fats, Foodstuffs for particular nutritional uses","search_zh":"食品浓缩制品，肉与肉制品，乳与乳制品，鱼与鱼制品，甜食与糖果制品，面包与烘焙半成品，谷物与谷物制品，冷冻食品，熟食制品，无酒精饮料（含气、不含气、果汁、糖浆、果蜜），水果与蔬菜、果蔬制品及蔬菜肉类制品，动植物油脂 PN-A-79011-6:1998+Az1:2008 pkt 3.3.5","test_object_zh":"食品浓缩制品，肉与肉制品，乳与乳制品，鱼与鱼制品，甜食与糖果制品，面包与烘焙半成品，谷物与谷物制品，冷冻食品，熟食制品，无酒精饮料（含气、不含气、果汁、糖浆、果蜜），水果与蔬菜、果蔬制品及蔬菜肉类制品，动植物油脂"},{"_id":"6a836a14af14b9c0e7b1deee","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Koncentraty spożywcze, Mięso i produkty mięsne, Mleko i produkty mleczne, Ryby i przetwory rybne, Słodycze i wyroby cukiernicze, Pieczywo i półprodukty piekarnicze, Zboża i przetwory zbożowe, Żywność mrożona, Wyroby garmażeryjne, Napoje bezalkoholowe, (gazowane, niegazowane, soki, syropy, nektary), Owoce i warzywa, przetwory owocowe i warzywne oraz warzywno-mięsne, Oleje i tłuszcze roślinne i zwierzęce, Środki specjalnego przeznaczenia żywieniowego","methodology":"Zawartość węglowodanów (ogółem i przyswajalnych) [g/100g] (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość węglowodanów (ogółem i przyswajalnych) [g/100g] (z obliczeń)","reference":"Rozporządzenie Parlamentu Europejskiego i Rady (UE) Nr 1169/2011 z dnia 25.10.2011r. Załącznik XIV","norm_bases":["Rozporządzenie Parlamentu Europejskiego i Rady (UE) Nr 1169/2011 z dnia 25.10.2011r. Załącznik XIV"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Koncentraty spożywcze, Mięso i produkty mięsne, Mleko i produkty mleczne, Ryby i przetwory rybne, Słodycze i wyroby cukiernicze, Pieczywo i półprodukty piekarnicze, Zboża i przetwory zbożowe, Żywność mrożona, Wyroby garmażeryjne, Napoje bezalkoholowe, (gazowane, niegazowane, soki, syropy, nektary), Owoce i warzywa, przetwory owocowe i warzywne oraz warzywno-mięsne, Oleje i tłuszcze roślinne i zwierzęce, Środki specjalnego przeznaczenia żywieniowego Zawartość węglowodanów (ogółem i przyswajalnych) [g/100g] (z obliczeń) Rozporządzenie Parlamentu Europejskiego i Rady (UE) Nr 1169/2011 z dnia 25.10.2011r. Załącznik XIV Koncentraty spozywcze, Mieso i produkty miesne, Mleko i produkty mleczne, Ryby i przetwory rybne, Slodycze i wyroby cukiernicze, Pieczywo i polprodukty piekarnicze, Zboza i przetwory zbozowe, Zywnosc mrozona, Wyroby garmazeryjne, Napoje bezalkoholowe, (gazowane, niegazowane, soki, syropy, nektary), Owoce i warzywa, przetwory owocowe i warzywne oraz warzywno-miesne, Oleje i tluszcze roslinne i zwierzece, Srodki specjalnego przeznaczenia zywieniowego Zawartosc weglowodanow (ogolem i przyswajalnych) [g/100g] (z obliczen) Rozporzadzenie Parlamentu Europejskiego i Rady (UE) Nr 1169/2011 z dnia 25.10.2011r. Zalacznik XIV","categories":["food","petro"],"row_index":91,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of carbohydrates (total and available) [g/100g] (calculated)","search_en":"Food concentrates, Meat and meat products, Milk and dairy products, Fish and fish products, Sweets and confectionery, Bread and bakery semi-finished products, Cereals and cereal products, Frozen food, Delicatessen products, Non-alcoholic beverages, (carbonated, still, juices, syrups, nectars), Fruit and vegetables, fruit, vegetable and vegetable-meat preserves, Vegetable and animal oils and fats, Foodstuffs for particular nutritional uses Content of carbohydrates (total and available) [g/100g] (calculated) Rozporządzenie Parlamentu Europejskiego i Rady (UE) Nr 1169/2011 z dnia 25.10.2011r. Załącznik XIV","test_object_en":"Food concentrates, Meat and meat products, Milk and dairy products, Fish and fish products, Sweets and confectionery, Bread and bakery semi-finished products, Cereals and cereal products, Frozen food, Delicatessen products, Non-alcoholic beverages, (carbonated, still, juices, syrups, nectars), Fruit and vegetables, fruit, vegetable and vegetable-meat preserves, Vegetable and animal oils and fats, Foodstuffs for particular nutritional uses","search_zh":"食品浓缩制品，肉与肉制品，乳与乳制品，鱼与鱼制品，甜食与糖果制品，面包与烘焙半成品，谷物与谷物制品，冷冻食品，熟食制品，无酒精饮料（含气、不含气、果汁、糖浆、果蜜），水果与蔬菜、果蔬制品及蔬菜肉类制品，动植物油脂 Rozporządzenie Parlamentu Europejskiego i Rady (UE) Nr 1169/2011 z dnia 25.10.2011r. Załącznik XIV","test_object_zh":"食品浓缩制品，肉与肉制品，乳与乳制品，鱼与鱼制品，甜食与糖果制品，面包与烘焙半成品，谷物与谷物制品，冷冻食品，熟食制品，无酒精饮料（含气、不含气、果汁、糖浆、果蜜），水果与蔬菜、果蔬制品及蔬菜肉类制品，动植物油脂"},{"_id":"6a836a14af14b9c0e7b1deef","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Napoje bezalkoholowe (gazowane, niegazowane, soki, syropy, nektary), Owoce i warzywa, przetwory owocowe i warzywne oraz warzywno-mięsne, Słodycze i wyroby cukiernicze, Ryby i przetwory rybne, Mięso i przetwory mięsne, Wyroby garmażeryjne, Zboża i przetwory zbożowe, Dodatki do żywności","methodology":"Zawartość kwasu sorbowego","parameters":[{"name":"Zakres","range":"(5 − 2000) mg/kg; mg/l"},{"name":"Zawartość sorbinianu potasu","range":"(7 − 2680) mg/kg; mg/l"}],"technique":"Metoda chromatografii cieczowej z detekcją spektrofotometryczną (HPLC – UV)","techniques":["Metoda chromatografii cieczowej z detekcją spektrofotometryczną (HPLC – UV)"],"computed":[],"activity":"Zawartość kwasu sorbowego\nZakres:\nZakres (5 − 2000) mg/kg; mg/l\nZawartość sorbinianu potasu (7 − 2680) mg/kg; mg/l\nMetoda chromatografii cieczowej z detekcją spektrofotometryczną (HPLC – UV)","reference":"PB/PACH/28 wydanie 4 z dnia 05.01.2021r.","norm_bases":["PB/PACH/28 wydanie 4 z dnia 05.01.2021r."],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Napoje bezalkoholowe (gazowane, niegazowane, soki, syropy, nektary), Owoce i warzywa, przetwory owocowe i warzywne oraz warzywno-mięsne, Słodycze i wyroby cukiernicze, Ryby i przetwory rybne, Mięso i przetwory mięsne, Wyroby garmażeryjne, Zboża i przetwory zbożowe, Dodatki do żywności Zawartość kwasu sorbowego\nZakres:\nZakres (5 − 2000) mg/kg; mg/l\nZawartość sorbinianu potasu (7 − 2680) mg/kg; mg/l\nMetoda chromatografii cieczowej z detekcją spektrofotometryczną (HPLC – UV) PB/PACH/28 wydanie 4 z dnia 05.01.2021r. Napoje bezalkoholowe (gazowane, niegazowane, soki, syropy, nektary), Owoce i warzywa, przetwory owocowe i warzywne oraz warzywno-miesne, Slodycze i wyroby cukiernicze, Ryby i przetwory rybne, Mieso i przetwory miesne, Wyroby garmazeryjne, Zboza i przetwory zbozowe, Dodatki do zywnosci Zawartosc kwasu sorbowego\nZakres:\nZakres (5 − 2000) mg/kg; mg/l\nZawartosc sorbinianu potasu (7 − 2680) mg/kg; mg/l\nMetoda chromatografii cieczowej z detekcja spektrofotometryczna (HPLC – UV) PB/PACH/28 wydanie 4 z dnia 05.01.2021r.","categories":["food"],"row_index":92,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sorbic acid content","parameters_en":[{"name":"Range","range":"(5 − 2000) mg/kg; mg/l"},{"name":"Potassium sorbate content","range":"(7 − 2680) mg/kg; mg/l"}],"search_en":"Non-alcoholic beverages (carbonated, still, juices, syrups, nectars), Fruit and vegetables, fruit and vegetable products and vegetable-meat products, Sweets and confectionery products, Fish and fish products, Meat and meat products, Delicatessen products, Cereals and cereal products, Food additives Sorbic acid content Liquid chromatography with spectrophotometric detection (HPLC – UV) Range Potassium sorbate content PB/PACH/28 wydanie 4 z dnia 05.01.2021r.","technique_en":"Liquid chromatography with spectrophotometric detection (HPLC – UV)","test_object_en":"Non-alcoholic beverages (carbonated, still, juices, syrups, nectars), Fruit and vegetables, fruit and vegetable products and vegetable-meat products, Sweets and confectionery products, Fish and fish products, Meat and meat products, Delicatessen products, Cereals and cereal products, Food additives","parameters_zh":[{"name":"范围","range":"(5 − 2000) mg/kg; mg/l"},{"name":"Zawartość sorbinianu potasu","range":"(7 − 2680) mg/kg; mg/l"}],"search_zh":"山梨酸含量 范围 PB/PACH/28 wydanie 4 z dnia 05.01.2021r.","methodology_zh":"山梨酸含量"},{"_id":"6a836a14af14b9c0e7b1def0","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Napoje bezalkoholowe (gazowane, niegazowane, soki, syropy, nektary), Owoce i warzywa, przetwory owocowe i warzywne oraz warzywno-mięsne, Słodycze i wyroby cukiernicze, Ryby i przetwory rybne, Mięso i przetwory mięsne, Wyroby garmażeryjne, Zboża i przetwory zbożowe, Dodatki do żywności","methodology":"Zawartość kwasu benzoesowego","parameters":[{"name":"Zakres","range":"(5 − 2000) mg/kg; mg/l"},{"name":"Zawartość benzoesanu sodu"},{"name":"Zakres","range":"(6 − 2360) mg/kg; mg/l"}],"technique":"Metoda chromatografii cieczowej z detekcją spektrofotometryczną (HPLC – UV)","techniques":["Metoda chromatografii cieczowej z detekcją spektrofotometryczną (HPLC – UV)"],"computed":[],"activity":"Zawartość kwasu benzoesowego\nZakres:\nZakres (5 − 2000) mg/kg; mg/l\nZawartość benzoesanu sodu\nZakres (6 − 2360) mg/kg; mg/l\nMetoda chromatografii cieczowej z detekcją spektrofotometryczną (HPLC – UV)","reference":"PB/PACH/28 wydanie 4 z dnia 05.01.2021r.","norm_bases":["PB/PACH/28 wydanie 4 z dnia 05.01.2021r."],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Napoje bezalkoholowe (gazowane, niegazowane, soki, syropy, nektary), Owoce i warzywa, przetwory owocowe i warzywne oraz warzywno-mięsne, Słodycze i wyroby cukiernicze, Ryby i przetwory rybne, Mięso i przetwory mięsne, Wyroby garmażeryjne, Zboża i przetwory zbożowe, Dodatki do żywności Zawartość kwasu benzoesowego\nZakres:\nZakres (5 − 2000) mg/kg; mg/l\nZawartość benzoesanu sodu\nZakres (6 − 2360) mg/kg; mg/l\nMetoda chromatografii cieczowej z detekcją spektrofotometryczną (HPLC – UV) PB/PACH/28 wydanie 4 z dnia 05.01.2021r. Napoje bezalkoholowe (gazowane, niegazowane, soki, syropy, nektary), Owoce i warzywa, przetwory owocowe i warzywne oraz warzywno-miesne, Slodycze i wyroby cukiernicze, Ryby i przetwory rybne, Mieso i przetwory miesne, Wyroby garmazeryjne, Zboza i przetwory zbozowe, Dodatki do zywnosci Zawartosc kwasu benzoesowego\nZakres:\nZakres (5 − 2000) mg/kg; mg/l\nZawartosc benzoesanu sodu\nZakres (6 − 2360) mg/kg; mg/l\nMetoda chromatografii cieczowej z detekcja spektrofotometryczna (HPLC – UV) PB/PACH/28 wydanie 4 z dnia 05.01.2021r.","categories":["food"],"row_index":93,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Benzoic acid content","parameters_en":[{"name":"Range","range":"(5 − 2000) mg/kg; mg/l"},{"name":"Sodium benzoate content"},{"name":"Range","range":"(6 − 2360) mg/kg; mg/l"}],"search_en":"Non-alcoholic beverages (carbonated, still, juices, syrups, nectars), Fruit and vegetables, fruit and vegetable products and vegetable-meat products, Sweets and confectionery products, Fish and fish products, Meat and meat products, Delicatessen products, Cereals and cereal products, Food additives Benzoic acid content Liquid chromatography with spectrophotometric detection (HPLC – UV) Range Sodium benzoate content Range PB/PACH/28 wydanie 4 z dnia 05.01.2021r.","technique_en":"Liquid chromatography with spectrophotometric detection (HPLC – UV)","test_object_en":"Non-alcoholic beverages (carbonated, still, juices, syrups, nectars), Fruit and vegetables, fruit and vegetable products and vegetable-meat products, Sweets and confectionery products, Fish and fish products, Meat and meat products, Delicatessen products, Cereals and cereal products, Food additives","parameters_zh":[{"name":"范围","range":"(5 − 2000) mg/kg; mg/l"},{"name":"Zawartość benzoesanu sodu"},{"name":"范围","range":"(6 − 2360) mg/kg; mg/l"}],"search_zh":"苯甲酸含量 范围 范围 PB/PACH/28 wydanie 4 z dnia 05.01.2021r.","methodology_zh":"苯甲酸含量"},{"_id":"6a836a14af14b9c0e7b1def1","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Koncentraty spożywcze, Napoje bezalkoholowe (gazowane, niegazowane, soki, syropy, nektary), Owoce i warzywa, przetwory owocowe i warzywne oraz warzywno-mięsne, Słodycze i wyroby cukiernicze, Środki specjalnego przeznaczenia żywieniowego","methodology":"Zawartość witaminy C","parameters":[{"name":"Zakres","range":"(5,0 − 500) mg/100ml, mg/100g"}],"technique":"Metoda chromatografii cieczowej z detekcją spektrofotometryczną (HPLC – UV)","techniques":["Metoda chromatografii cieczowej z detekcją spektrofotometryczną (HPLC – UV)"],"computed":[],"activity":"Zawartość witaminy C\nZakres (5,0 − 500) mg/100ml, mg/100g\nMetoda chromatografii cieczowej z detekcją spektrofotometryczną (HPLC – UV)","reference":"PN-EN 14130:2004","norm_bases":["PN-EN 14130:2004"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Koncentraty spożywcze, Napoje bezalkoholowe (gazowane, niegazowane, soki, syropy, nektary), Owoce i warzywa, przetwory owocowe i warzywne oraz warzywno-mięsne, Słodycze i wyroby cukiernicze, Środki specjalnego przeznaczenia żywieniowego Zawartość witaminy C\nZakres (5,0 − 500) mg/100ml, mg/100g\nMetoda chromatografii cieczowej z detekcją spektrofotometryczną (HPLC – UV) PN-EN 14130:2004 Koncentraty spozywcze, Napoje bezalkoholowe (gazowane, niegazowane, soki, syropy, nektary), Owoce i warzywa, przetwory owocowe i warzywne oraz warzywno-miesne, Slodycze i wyroby cukiernicze, Srodki specjalnego przeznaczenia zywieniowego Zawartosc witaminy C\nZakres (5,0 − 500) mg/100ml, mg/100g\nMetoda chromatografii cieczowej z detekcja spektrofotometryczna (HPLC – UV) PN-EN 14130:2004","categories":["food"],"row_index":94,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Vitamin C content","parameters_en":[{"name":"Range","range":"(5,0 − 500) mg/100ml, mg/100g"}],"search_en":"Food concentrates, Non-alcoholic beverages (carbonated, still, juices, syrups, nectars), Fruit and vegetables, fruit and vegetable products and vegetable-meat products, Sweets and confectionery, Foodstuffs for particular nutritional uses Vitamin C content Liquid chromatography with spectrophotometric detection (HPLC – UV) Range PN-EN 14130:2004","technique_en":"Liquid chromatography with spectrophotometric detection (HPLC – UV)","test_object_en":"Food concentrates, Non-alcoholic beverages (carbonated, still, juices, syrups, nectars), Fruit and vegetables, fruit and vegetable products and vegetable-meat products, Sweets and confectionery, Foodstuffs for particular nutritional uses","parameters_zh":[{"name":"范围","range":"(5,0 − 500) mg/100ml, mg/100g"}],"search_zh":"维生素C含量 范围 PN-EN 14130:2004","methodology_zh":"维生素C含量"},{"_id":"6a836a14af14b9c0e7b1def2","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Owoce i warzywa, przetwory owocowe i warzywne oraz warzywno-mięsne (orzechy, owoce suszone, kukurydza), Słodycze i wyroby cukiernicze, Surowce i przetwory zielarskie, przyprawy, Środki specjalnego przeznaczenia żywieniowego, Zboża i przetwory zbożowe, Ryż, Wyroby garmażeryjne, Pasze","methodology":"Zawartość aflatoksyny B1","parameters":[{"name":"Zakres","range":"(0,086 - 60) µg/kg"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją FLD fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją FLD fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Zawartość aflatoksyny B1\nZakres (0,086 - 60) µg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją FLD fluorescencyjną (HPLC-FLD)","reference":"PB/PACH/34 wydanie 4 z dnia 25.04.2022 r.","norm_bases":["PB/PACH/34 wydanie 4 z dnia 25.04.2022 r."],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Owoce i warzywa, przetwory owocowe i warzywne oraz warzywno-mięsne (orzechy, owoce suszone, kukurydza), Słodycze i wyroby cukiernicze, Surowce i przetwory zielarskie, przyprawy, Środki specjalnego przeznaczenia żywieniowego, Zboża i przetwory zbożowe, Ryż, Wyroby garmażeryjne, Pasze Zawartość aflatoksyny B1\nZakres (0,086 - 60) µg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją FLD fluorescencyjną (HPLC-FLD) PB/PACH/34 wydanie 4 z dnia 25.04.2022 r. Owoce i warzywa, przetwory owocowe i warzywne oraz warzywno-miesne (orzechy, owoce suszone, kukurydza), Slodycze i wyroby cukiernicze, Surowce i przetwory zielarskie, przyprawy, Srodki specjalnego przeznaczenia zywieniowego, Zboza i przetwory zbozowe, Ryz, Wyroby garmazeryjne, Pasze Zawartosc aflatoksyny B1\nZakres (0,086 - 60) µg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcja FLD fluorescencyjna (HPLC-FLD) PB/PACH/34 wydanie 4 z dnia 25.04.2022 r.","categories":["food"],"row_index":95,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Aflatoxin B1 content","parameters_en":[{"name":"Range","range":"(0,086 - 60) µg/kg"}],"search_en":"Fruit and vegetables, fruit, vegetable and vegetable-meat preserves (nuts, dried fruit, maize), Sweets and confectionery, Herbal raw materials and preparations, spices, Foodstuffs for particular nutritional uses, Cereals and cereal products, Rice, Delicatessen products, Feed Aflatoxin B1 content High-performance liquid chromatography with FLD fluorescence detection (HPLC-FLD) Range PB/PACH/34 wydanie 4 z dnia 25.04.2022 r.","technique_en":"High-performance liquid chromatography with FLD fluorescence detection (HPLC-FLD)","test_object_en":"Fruit and vegetables, fruit, vegetable and vegetable-meat preserves (nuts, dried fruit, maize), Sweets and confectionery, Herbal raw materials and preparations, spices, Foodstuffs for particular nutritional uses, Cereals and cereal products, Rice, Delicatessen products, Feed","parameters_zh":[{"name":"范围","range":"(0,086 - 60) µg/kg"}],"search_zh":"水果与蔬菜、果蔬制品及蔬菜肉类制品（坚果、干果、玉米），甜食与糖果制品，草药原料与制品、香辛料，特殊营养用途食品，谷物与谷物制品，大米，熟食制品，饲料 黄曲霉毒素 B1 含量 高效液相色谱-荧光检测法（HPLC-FLD） 范围 PB/PACH/34 wydanie 4 z dnia 25.04.2022 r.","methodology_zh":"黄曲霉毒素 B1 含量","technique_zh":"高效液相色谱-荧光检测法（HPLC-FLD）","test_object_zh":"水果与蔬菜、果蔬制品及蔬菜肉类制品（坚果、干果、玉米），甜食与糖果制品，草药原料与制品、香辛料，特殊营养用途食品，谷物与谷物制品，大米，熟食制品，饲料"},{"_id":"6a836a14af14b9c0e7b1def3","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Owoce i warzywa, przetwory owocowe i warzywne oraz warzywno-mięsne (orzechy, owoce suszone, kukurydza), Słodycze i wyroby cukiernicze, Surowce i przetwory zielarskie, przyprawy, Środki specjalnego przeznaczenia żywieniowego, Zboża i przetwory zbożowe, Ryż, Wyroby garmażeryjne, Pasze","methodology":"Zawartość aflatoksyny B2","parameters":[{"name":"Zakres","range":"(0,058-37) µg/kg"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją FLD fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją FLD fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Zawartość aflatoksyny B2\nZakres (0,058-37) µg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją FLD fluorescencyjną (HPLC-FLD)","reference":"PB/PACH/34 wydanie 4 z dnia 25.04.2022 r.","norm_bases":["PB/PACH/34 wydanie 4 z dnia 25.04.2022 r."],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Owoce i warzywa, przetwory owocowe i warzywne oraz warzywno-mięsne (orzechy, owoce suszone, kukurydza), Słodycze i wyroby cukiernicze, Surowce i przetwory zielarskie, przyprawy, Środki specjalnego przeznaczenia żywieniowego, Zboża i przetwory zbożowe, Ryż, Wyroby garmażeryjne, Pasze Zawartość aflatoksyny B2\nZakres (0,058-37) µg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją FLD fluorescencyjną (HPLC-FLD) PB/PACH/34 wydanie 4 z dnia 25.04.2022 r. Owoce i warzywa, przetwory owocowe i warzywne oraz warzywno-miesne (orzechy, owoce suszone, kukurydza), Slodycze i wyroby cukiernicze, Surowce i przetwory zielarskie, przyprawy, Srodki specjalnego przeznaczenia zywieniowego, Zboza i przetwory zbozowe, Ryz, Wyroby garmazeryjne, Pasze Zawartosc aflatoksyny B2\nZakres (0,058-37) µg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcja FLD fluorescencyjna (HPLC-FLD) PB/PACH/34 wydanie 4 z dnia 25.04.2022 r.","categories":["food"],"row_index":96,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Aflatoxin B2 content","parameters_en":[{"name":"Range","range":"(0,058-37) µg/kg"}],"search_en":"Fruit and vegetables, fruit, vegetable and vegetable-meat preserves (nuts, dried fruit, maize), Sweets and confectionery, Herbal raw materials and preparations, spices, Foodstuffs for particular nutritional uses, Cereals and cereal products, Rice, Delicatessen products, Feed Aflatoxin B2 content High-performance liquid chromatography with FLD fluorescence detection (HPLC-FLD) Range PB/PACH/34 wydanie 4 z dnia 25.04.2022 r.","technique_en":"High-performance liquid chromatography with FLD fluorescence detection (HPLC-FLD)","test_object_en":"Fruit and vegetables, fruit, vegetable and vegetable-meat preserves (nuts, dried fruit, maize), Sweets and confectionery, Herbal raw materials and preparations, spices, Foodstuffs for particular nutritional uses, Cereals and cereal products, Rice, Delicatessen products, Feed","parameters_zh":[{"name":"范围","range":"(0,058-37) µg/kg"}],"search_zh":"水果与蔬菜、果蔬制品及蔬菜肉类制品（坚果、干果、玉米），甜食与糖果制品，草药原料与制品、香辛料，特殊营养用途食品，谷物与谷物制品，大米，熟食制品，饲料 高效液相色谱-荧光检测法（HPLC-FLD） 范围 PB/PACH/34 wydanie 4 z dnia 25.04.2022 r.","technique_zh":"高效液相色谱-荧光检测法（HPLC-FLD）","test_object_zh":"水果与蔬菜、果蔬制品及蔬菜肉类制品（坚果、干果、玉米），甜食与糖果制品，草药原料与制品、香辛料，特殊营养用途食品，谷物与谷物制品，大米，熟食制品，饲料"},{"_id":"6a836a14af14b9c0e7b1def4","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Owoce i warzywa, przetwory owocowe i warzywne oraz warzywno-mięsne (orzechy, owoce suszone, kukurydza), Słodycze i wyroby cukiernicze, Surowce i przetwory zielarskie, przyprawy, Środki specjalnego przeznaczenia żywieniowego, Zboża i przetwory zbożowe, Ryż, Wyroby garmażeryjne, Pasze","methodology":"Zawartość aflatoksyny G1","parameters":[{"name":"Zakres","range":"(0,086 - 60) µg/kg"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją FLD fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją FLD fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Zawartość aflatoksyny G1\nZakres (0,086 - 60) µg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją FLD fluorescencyjną (HPLC-FLD)","reference":"PB/PACH/34 wydanie 4 z dnia 25.04.2022 r.","norm_bases":["PB/PACH/34 wydanie 4 z dnia 25.04.2022 r."],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Owoce i warzywa, przetwory owocowe i warzywne oraz warzywno-mięsne (orzechy, owoce suszone, kukurydza), Słodycze i wyroby cukiernicze, Surowce i przetwory zielarskie, przyprawy, Środki specjalnego przeznaczenia żywieniowego, Zboża i przetwory zbożowe, Ryż, Wyroby garmażeryjne, Pasze Zawartość aflatoksyny G1\nZakres (0,086 - 60) µg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją FLD fluorescencyjną (HPLC-FLD) PB/PACH/34 wydanie 4 z dnia 25.04.2022 r. Owoce i warzywa, przetwory owocowe i warzywne oraz warzywno-miesne (orzechy, owoce suszone, kukurydza), Slodycze i wyroby cukiernicze, Surowce i przetwory zielarskie, przyprawy, Srodki specjalnego przeznaczenia zywieniowego, Zboza i przetwory zbozowe, Ryz, Wyroby garmazeryjne, Pasze Zawartosc aflatoksyny G1\nZakres (0,086 - 60) µg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcja FLD fluorescencyjna (HPLC-FLD) PB/PACH/34 wydanie 4 z dnia 25.04.2022 r.","categories":["food"],"row_index":97,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Aflatoxin G1 content","parameters_en":[{"name":"Range","range":"(0,086 - 60) µg/kg"}],"search_en":"Fruit and vegetables, fruit, vegetable and vegetable-meat preserves (nuts, dried fruit, maize), Sweets and confectionery, Herbal raw materials and preparations, spices, Foodstuffs for particular nutritional uses, Cereals and cereal products, Rice, Delicatessen products, Feed Aflatoxin G1 content High-performance liquid chromatography with FLD fluorescence detection (HPLC-FLD) Range PB/PACH/34 wydanie 4 z dnia 25.04.2022 r.","technique_en":"High-performance liquid chromatography with FLD fluorescence detection (HPLC-FLD)","test_object_en":"Fruit and vegetables, fruit, vegetable and vegetable-meat preserves (nuts, dried fruit, maize), Sweets and confectionery, Herbal raw materials and preparations, spices, Foodstuffs for particular nutritional uses, Cereals and cereal products, Rice, Delicatessen products, Feed","parameters_zh":[{"name":"范围","range":"(0,086 - 60) µg/kg"}],"search_zh":"水果与蔬菜、果蔬制品及蔬菜肉类制品（坚果、干果、玉米），甜食与糖果制品，草药原料与制品、香辛料，特殊营养用途食品，谷物与谷物制品，大米，熟食制品，饲料 高效液相色谱-荧光检测法（HPLC-FLD） 范围 PB/PACH/34 wydanie 4 z dnia 25.04.2022 r.","technique_zh":"高效液相色谱-荧光检测法（HPLC-FLD）","test_object_zh":"水果与蔬菜、果蔬制品及蔬菜肉类制品（坚果、干果、玉米），甜食与糖果制品，草药原料与制品、香辛料，特殊营养用途食品，谷物与谷物制品，大米，熟食制品，饲料"},{"_id":"6a836a14af14b9c0e7b1def5","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Owoce i warzywa, przetwory owocowe i warzywne oraz warzywno-mięsne (orzechy, owoce suszone, kukurydza), Słodycze i wyroby cukiernicze, Surowce i przetwory zielarskie, przyprawy, Środki specjalnego przeznaczenia żywieniowego, Zboża i przetwory zbożowe, Ryż, Wyroby garmażeryjne, Pasze","methodology":"Zawartość aflatoksyny G2","parameters":[{"name":"Zakres","range":"(0,058-37) µg/kg"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją FLD fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją FLD fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Zawartość aflatoksyny G2\nZakres (0,058-37) µg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją FLD fluorescencyjną (HPLC-FLD)","reference":"PB/PACH/34 wydanie 4 z dnia 25.04.2022 r.","norm_bases":["PB/PACH/34 wydanie 4 z dnia 25.04.2022 r."],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Owoce i warzywa, przetwory owocowe i warzywne oraz warzywno-mięsne (orzechy, owoce suszone, kukurydza), Słodycze i wyroby cukiernicze, Surowce i przetwory zielarskie, przyprawy, Środki specjalnego przeznaczenia żywieniowego, Zboża i przetwory zbożowe, Ryż, Wyroby garmażeryjne, Pasze Zawartość aflatoksyny G2\nZakres (0,058-37) µg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją FLD fluorescencyjną (HPLC-FLD) PB/PACH/34 wydanie 4 z dnia 25.04.2022 r. Owoce i warzywa, przetwory owocowe i warzywne oraz warzywno-miesne (orzechy, owoce suszone, kukurydza), Slodycze i wyroby cukiernicze, Surowce i przetwory zielarskie, przyprawy, Srodki specjalnego przeznaczenia zywieniowego, Zboza i przetwory zbozowe, Ryz, Wyroby garmazeryjne, Pasze Zawartosc aflatoksyny G2\nZakres (0,058-37) µg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcja FLD fluorescencyjna (HPLC-FLD) PB/PACH/34 wydanie 4 z dnia 25.04.2022 r.","categories":["food"],"row_index":98,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Aflatoxin G2 content","parameters_en":[{"name":"Range","range":"(0,058-37) µg/kg"}],"search_en":"Fruit and vegetables, fruit, vegetable and vegetable-meat preserves (nuts, dried fruit, maize), Sweets and confectionery, Herbal raw materials and preparations, spices, Foodstuffs for particular nutritional uses, Cereals and cereal products, Rice, Delicatessen products, Feed Aflatoxin G2 content High-performance liquid chromatography with FLD fluorescence detection (HPLC-FLD) Range PB/PACH/34 wydanie 4 z dnia 25.04.2022 r.","technique_en":"High-performance liquid chromatography with FLD fluorescence detection (HPLC-FLD)","test_object_en":"Fruit and vegetables, fruit, vegetable and vegetable-meat preserves (nuts, dried fruit, maize), Sweets and confectionery, Herbal raw materials and preparations, spices, Foodstuffs for particular nutritional uses, Cereals and cereal products, Rice, Delicatessen products, Feed","parameters_zh":[{"name":"范围","range":"(0,058-37) µg/kg"}],"search_zh":"水果与蔬菜、果蔬制品及蔬菜肉类制品（坚果、干果、玉米），甜食与糖果制品，草药原料与制品、香辛料，特殊营养用途食品，谷物与谷物制品，大米，熟食制品，饲料 高效液相色谱-荧光检测法（HPLC-FLD） 范围 PB/PACH/34 wydanie 4 z dnia 25.04.2022 r.","technique_zh":"高效液相色谱-荧光检测法（HPLC-FLD）","test_object_zh":"水果与蔬菜、果蔬制品及蔬菜肉类制品（坚果、干果、玉米），甜食与糖果制品，草药原料与制品、香辛料，特殊营养用途食品，谷物与谷物制品，大米，熟食制品，饲料"},{"_id":"6a836a14af14b9c0e7b1def6","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Owoce i warzywa, przetwory owocowe i warzywne oraz warzywno-mięsne (orzechy, owoce suszone, kukurydza), Słodycze i wyroby cukiernicze, Surowce i przetwory zielarskie, przyprawy, Środki specjalnego przeznaczenia żywieniowego, Zboża i przetwory zbożowe, Ryż, Wyroby garmażeryjne, Pasze","methodology":"Suma aflatoksyn B1, B2, G1, G2 (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma aflatoksyn B1, B2, G1, G2 (z obliczeń)","reference":"PB/PACH/34 wydanie 4 z dnia 25.04.2022 r.","norm_bases":["PB/PACH/34 wydanie 4 z dnia 25.04.2022 r."],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Owoce i warzywa, przetwory owocowe i warzywne oraz warzywno-mięsne (orzechy, owoce suszone, kukurydza), Słodycze i wyroby cukiernicze, Surowce i przetwory zielarskie, przyprawy, Środki specjalnego przeznaczenia żywieniowego, Zboża i przetwory zbożowe, Ryż, Wyroby garmażeryjne, Pasze Suma aflatoksyn B1, B2, G1, G2 (z obliczeń) PB/PACH/34 wydanie 4 z dnia 25.04.2022 r. Owoce i warzywa, przetwory owocowe i warzywne oraz warzywno-miesne (orzechy, owoce suszone, kukurydza), Slodycze i wyroby cukiernicze, Surowce i przetwory zielarskie, przyprawy, Srodki specjalnego przeznaczenia zywieniowego, Zboza i przetwory zbozowe, Ryz, Wyroby garmazeryjne, Pasze Suma aflatoksyn B1, B2, G1, G2 (z obliczen) PB/PACH/34 wydanie 4 z dnia 25.04.2022 r.","categories":["food"],"row_index":99,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of aflatoxins B1, B2, G1, G2 (calculated)","search_en":"Fruit and vegetables, fruit, vegetable and vegetable-meat preserves (nuts, dried fruit, maize), Sweets and confectionery, Herbal raw materials and preparations, spices, Foodstuffs for particular nutritional uses, Cereals and cereal products, Rice, Delicatessen products, Feed Sum of aflatoxins B1, B2, G1, G2 (calculated) PB/PACH/34 wydanie 4 z dnia 25.04.2022 r.","test_object_en":"Fruit and vegetables, fruit, vegetable and vegetable-meat preserves (nuts, dried fruit, maize), Sweets and confectionery, Herbal raw materials and preparations, spices, Foodstuffs for particular nutritional uses, Cereals and cereal products, Rice, Delicatessen products, Feed","search_zh":"水果与蔬菜、果蔬制品及蔬菜肉类制品（坚果、干果、玉米），甜食与糖果制品，草药原料与制品、香辛料，特殊营养用途食品，谷物与谷物制品，大米，熟食制品，饲料 PB/PACH/34 wydanie 4 z dnia 25.04.2022 r.","test_object_zh":"水果与蔬菜、果蔬制品及蔬菜肉类制品（坚果、干果、玉米），甜食与糖果制品，草药原料与制品、香辛料，特殊营养用途食品，谷物与谷物制品，大米，熟食制品，饲料"},{"_id":"6a836a14af14b9c0e7b1def7","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Kawa mielona, Kawa ziarnista, Kawa rozpuszczalna","methodology":"Zawartość kofeiny","parameters":[{"name":"Zakres","range":"(30 – 45000) mg/kg"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC – UV/DAD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC – UV/DAD)"],"computed":[],"activity":"Zawartość kofeiny\nZakres (30 – 45000) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC – UV/DAD)","reference":"PN-ISO 10095:1997","norm_bases":["PN-ISO 10095:1997"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kawa mielona, Kawa ziarnista, Kawa rozpuszczalna Zawartość kofeiny\nZakres (30 – 45000) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC – UV/DAD) PN-ISO 10095:1997 Kawa mielona, Kawa ziarnista, Kawa rozpuszczalna Zawartosc kofeiny\nZakres (30 – 45000) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC – UV/DAD) PN-ISO 10095:1997","categories":["other"],"row_index":100,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Caffeine content","parameters_en":[{"name":"Range","range":"(30 – 45000) mg/kg"}],"search_en":"Ground coffee, Coffee beans, Instant coffee Caffeine content High-performance liquid chromatography with spectrophotometric detection (HPLC – UV/DAD) Range PN-ISO 10095:1997","technique_en":"High-performance liquid chromatography with spectrophotometric detection (HPLC – UV/DAD)","test_object_en":"Ground coffee, Coffee beans, Instant coffee","parameters_zh":[{"name":"范围","range":"(30 – 45000) mg/kg"}],"search_zh":"咖啡因含量 范围 PN-ISO 10095:1997","methodology_zh":"咖啡因含量"},{"_id":"6a836a14af14b9c0e7b1def8","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Kawa bezkofeinowa, Napoje kawowe","methodology":"Zawartość kofeiny","parameters":[{"name":"Zakres","range":"(30 – 3500) mg/kg;"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC – UV/DAD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC – UV/DAD)"],"computed":[],"activity":"Zawartość kofeiny\nZakres (30 – 3500) mg/kg;\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC – UV/DAD)","reference":"PN-ISO 10095:1997","norm_bases":["PN-ISO 10095:1997"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kawa bezkofeinowa, Napoje kawowe Zawartość kofeiny\nZakres (30 – 3500) mg/kg;\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC – UV/DAD) PN-ISO 10095:1997 Kawa bezkofeinowa, Napoje kawowe Zawartosc kofeiny\nZakres (30 – 3500) mg/kg;\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC – UV/DAD) PN-ISO 10095:1997","categories":["food"],"row_index":101,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Caffeine content","parameters_en":[{"name":"Range","range":"(30 – 3500) mg/kg;"}],"search_en":"Decaffeinated coffee, Coffee beverages Caffeine content High-performance liquid chromatography with spectrophotometric detection (HPLC – UV/DAD) Range PN-ISO 10095:1997","technique_en":"High-performance liquid chromatography with spectrophotometric detection (HPLC – UV/DAD)","test_object_en":"Decaffeinated coffee, Coffee beverages","parameters_zh":[{"name":"范围","range":"(30 – 3500) mg/kg;"}],"search_zh":"咖啡因含量 范围 PN-ISO 10095:1997","methodology_zh":"咖啡因含量"},{"_id":"6a836a14af14b9c0e7b1def9","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Napoje energetyczne","methodology":"Zawartość kofeiny","parameters":[{"name":"Zakres","range":"(0,5 – 400) mg/l;"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC – UV/DAD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC – UV/DAD)"],"computed":[],"activity":"Zawartość kofeiny\nZakres (0,5 – 400) mg/l;\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC – UV/DAD)","reference":"PN-ISO 10095:1997","norm_bases":["PN-ISO 10095:1997"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Napoje energetyczne Zawartość kofeiny\nZakres (0,5 – 400) mg/l;\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC – UV/DAD) PN-ISO 10095:1997 Napoje energetyczne Zawartosc kofeiny\nZakres (0,5 – 400) mg/l;\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC – UV/DAD) PN-ISO 10095:1997","categories":["food"],"row_index":102,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Caffeine content","parameters_en":[{"name":"Range","range":"(0,5 – 400) mg/l;"}],"search_en":"Energy drinks Caffeine content High-performance liquid chromatography with spectrophotometric detection (HPLC – UV/DAD) Range PN-ISO 10095:1997","technique_en":"High-performance liquid chromatography with spectrophotometric detection (HPLC – UV/DAD)","test_object_en":"Energy drinks","parameters_zh":[{"name":"范围","range":"(0,5 – 400) mg/l;"}],"search_zh":"咖啡因含量 范围 PN-ISO 10095:1997","methodology_zh":"咖啡因含量"},{"_id":"6a836a14af14b9c0e7b1defa","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Sok jabłkowy i przetwory z jabłek, w tym produkty dla niemowląt i małych dzieci","methodology":"Zawartość patuliny","parameters":[{"name":"Zakres","range":"(5,0 – 200,0) µg/kg"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV/DAD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV/DAD)"],"computed":[],"activity":"Zawartość patuliny\nZakres (5,0 – 200,0) µg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV/DAD)","reference":"Wydawnictwo Metodyczne PZH - 2005","norm_bases":["Wydawnictwo Metodyczne PZH - 2005"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Sok jabłkowy i przetwory z jabłek, w tym produkty dla niemowląt i małych dzieci Zawartość patuliny\nZakres (5,0 – 200,0) µg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV/DAD) Wydawnictwo Metodyczne PZH - 2005 Sok jablkowy i przetwory z jablek, w tym produkty dla niemowlat i malych dzieci Zawartosc patuliny\nZakres (5,0 – 200,0) µg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC-UV/DAD) Wydawnictwo Metodyczne PZH - 2005","categories":["other"],"row_index":103,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Patulin content","parameters_en":[{"name":"Range","range":"(5,0 – 200,0) µg/kg"}],"search_en":"Apple juice and apple products, including products for infants and young children Patulin content High-performance liquid chromatography with spectrophotometric detection (HPLC-UV/DAD) Range Wydawnictwo Metodyczne PZH - 2005","technique_en":"High-performance liquid chromatography with spectrophotometric detection (HPLC-UV/DAD)","test_object_en":"Apple juice and apple products, including products for infants and young children","parameters_zh":[{"name":"范围","range":"(5,0 – 200,0) µg/kg"}],"search_zh":"展青霉素含量 范围 Wydawnictwo Metodyczne PZH - 2005","methodology_zh":"展青霉素含量"},{"_id":"6a836a14af14b9c0e7b1defb","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-5:2017-10","norm_bases":["PN-ISO 5667-5:2017-10"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-5:2017-10 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-5:2017-10","categories":["water"],"row_index":104,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Water intended for human consumption Sampling for chemical and physical testing PN-ISO 5667-5:2017-10","test_object_en":"Water intended for human consumption","methodology_zh":"化学与物理检测用样品采集","search_zh":"生活饮用水 化学与物理检测用样品采集 PN-ISO 5667-5:2017-10","test_object_zh":"生活饮用水"},{"_id":"6a836a14af14b9c0e7b1defc","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(5 − 50) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Barwa\nZakres (5 − 50) mg/l Pt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012","norm_bases":["PN-EN ISO 7887:2012"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Barwa\nZakres (5 − 50) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 Woda do spozycia przez ludzi Barwa\nZakres (5 − 50) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012","categories":["water"],"row_index":105,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"(5 − 50) mg/l Pt"}],"search_en":"Water intended for human consumption Colour Spectrophotometric method Range PN-EN ISO 7887:2012","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(5 − 50) mg/l Pt"}],"search_zh":"生活饮用水 色度 分光光度法 范围 PN-EN ISO 7887:2012","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a836a14af14b9c0e7b1defd","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,10 − 100) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,10 − 100) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Mętność\nZakres (0,10 − 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda do spozycia przez ludzi Metnosc\nZakres (0,10 − 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":106,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,10 − 100) NTU"}],"search_en":"Water intended for human consumption Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09","technique_en":"Nephelometric method","test_object_en":"Water intended for human consumption","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,10 − 100) NTU"}],"search_zh":"生活饮用水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"生活饮用水"},{"_id":"6a836a14af14b9c0e7b1defe","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(1,0 − 3000) µS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (1,0 − 3000) µS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Przewodność elektryczna właściwa\nZakres (1,0 − 3000) µS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa\nZakres (1,0 − 3000) µS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":107,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(1,0 − 3000) µS/cm"}],"search_en":"Water intended for human consumption Electrical conductivity Conductometric method Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water intended for human consumption","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(1,0 − 3000) µS/cm"}],"search_zh":"生活饮用水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"生活饮用水"},{"_id":"6a836a14af14b9c0e7b1deff","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Indeks nadmanganianowy (Utlenialność)","parameters":[{"name":"Zakres","range":"(0,50 – 10,0) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Indeks nadmanganianowy (Utlenialność)\nZakres (0,50 – 10,0) mg/l\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Indeks nadmanganianowy (Utlenialność)\nZakres (0,50 – 10,0) mg/l\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda do spozycia przez ludzi Indeks nadmanganianowy (Utlenialnosc)\nZakres (0,50 – 10,0) mg/l\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":108,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Permanganate index (Oxidisability)","parameters_en":[{"name":"Range","range":"(0,50 – 10,0) mg/l"}],"search_en":"Water intended for human consumption Permanganate index (Oxidisability) Titrimetric method Range PN-EN ISO 8467:2001","technique_en":"Titrimetric method","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,50 – 10,0) mg/l"}],"search_zh":"生活饮用水 高锰酸盐指数（耗氧量） 滴定法 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"生活饮用水","methodology_zh":"高锰酸盐指数（耗氧量）"},{"_id":"6a836a14af14b9c0e7b1df00","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba progowa smaku TFN","parameters":[{"name":"Zakres","range":"(1 – 4)"}],"technique":"Metoda parzysta uproszczona i pełna wyboru niewymuszonego","techniques":["Metoda parzysta uproszczona i pełna wyboru niewymuszonego"],"computed":[],"activity":"Liczba progowa smaku TFN\nZakres (1 – 4)\nMetoda parzysta uproszczona i pełna wyboru niewymuszonego","reference":"PN-EN 1622:2006","norm_bases":["PN-EN 1622:2006"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba progowa smaku TFN\nZakres (1 – 4)\nMetoda parzysta uproszczona i pełna wyboru niewymuszonego PN-EN 1622:2006 Woda do spozycia przez ludzi Liczba progowa smaku TFN\nZakres (1 – 4)\nMetoda parzysta uproszczona i pelna wyboru niewymuszonego PN-EN 1622:2006","categories":["water"],"row_index":109,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Taste threshold number TFN","parameters_en":[{"name":"Range","range":"(1 – 4)"}],"search_en":"Water intended for human consumption Taste threshold number TFN Simplified and full paired method with non-forced choice Range PN-EN 1622:2006","technique_en":"Simplified and full paired method with non-forced choice","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(1 – 4)"}],"search_zh":"生活饮用水 味阈值 TFN 成对简化法与完全法，非强制选择 范围 PN-EN 1622:2006","test_object_zh":"生活饮用水","methodology_zh":"味阈值 TFN","technique_zh":"成对简化法与完全法，非强制选择"},{"_id":"6a836a14af14b9c0e7b1df01","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba progowa zapachu TON","parameters":[{"name":"Zakres","range":"(1 – 4)"}],"technique":"Metoda parzysta uproszczona i pełna wyboru niewymuszonego","techniques":["Metoda parzysta uproszczona i pełna wyboru niewymuszonego"],"computed":[],"activity":"Liczba progowa zapachu TON\nZakres (1 – 4)\nMetoda parzysta uproszczona i pełna wyboru niewymuszonego","reference":"PN-EN 1622:2006","norm_bases":["PN-EN 1622:2006"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba progowa zapachu TON\nZakres (1 – 4)\nMetoda parzysta uproszczona i pełna wyboru niewymuszonego PN-EN 1622:2006 Woda do spozycia przez ludzi Liczba progowa zapachu TON\nZakres (1 – 4)\nMetoda parzysta uproszczona i pelna wyboru niewymuszonego PN-EN 1622:2006","categories":["water"],"row_index":110,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Odour threshold number TON","parameters_en":[{"name":"Range","range":"(1 – 4)"}],"search_en":"Water intended for human consumption Odour threshold number TON Simplified and full paired method with non-forced choice Range PN-EN 1622:2006","technique_en":"Simplified and full paired method with non-forced choice","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(1 – 4)"}],"search_zh":"生活饮用水 嗅阈值 TON 成对简化法与完全法，非强制选择 范围 PN-EN 1622:2006","test_object_zh":"生活饮用水","methodology_zh":"嗅阈值 TON","technique_zh":"成对简化法与完全法，非强制选择"},{"_id":"6a836a14af14b9c0e7b1df02","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie kationów:","parameters":[{"name":"litowy","range":"(0,01 – 10) mg/l"},{"name":"sodowy","range":"(1,0 – 200) mg/l"},{"name":"amonowy","range":"(0,05 – 10) mg/l"},{"name":"magnezowy","range":"(1,0 – 100) mg/l"},{"name":"potasowy","range":"(0,2 – 50) mg/l"},{"name":"wapniowy","range":"(5,0 – 150) mg/l"},{"name":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna) mg/l (z obliczeń)"}],"technique":"Metoda chromatografii jonowej (IC)","techniques":["Metoda chromatografii jonowej (IC)"],"computed":[],"activity":"Stężenie kationów:\nZakres:\nlitowy (0,01 – 10) mg/l\nsodowy (1,0 – 200) mg/l\namonowy (0,05 – 10) mg/l\nmagnezowy (1,0 – 100) mg/l\npotasowy (0,2 – 50) mg/l\nwapniowy (5,0 – 150) mg/l\nSumaryczna zawartość wapnia i magnezu (twardość ogólna) mg/l (z obliczeń)\nMetoda chromatografii jonowej (IC)","reference":"PN-EN ISO 14911:2002","norm_bases":["PN-EN ISO 14911:2002"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie kationów:\nZakres:\nlitowy (0,01 – 10) mg/l\nsodowy (1,0 – 200) mg/l\namonowy (0,05 – 10) mg/l\nmagnezowy (1,0 – 100) mg/l\npotasowy (0,2 – 50) mg/l\nwapniowy (5,0 – 150) mg/l\nSumaryczna zawartość wapnia i magnezu (twardość ogólna) mg/l (z obliczeń)\nMetoda chromatografii jonowej (IC) PN-EN ISO 14911:2002 Woda Stezenie kationow:\nZakres:\nlitowy (0,01 – 10) mg/l\nsodowy (1,0 – 200) mg/l\namonowy (0,05 – 10) mg/l\nmagnezowy (1,0 – 100) mg/l\npotasowy (0,2 – 50) mg/l\nwapniowy (5,0 – 150) mg/l\nSumaryczna zawartosc wapnia i magnezu (twardosc ogolna) mg/l (z obliczen)\nMetoda chromatografii jonowej (IC) PN-EN ISO 14911:2002","categories":["water"],"row_index":111,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Cation concentrations:","parameters_en":[{"name":"lithium","range":"(0,01 – 10) mg/l"},{"name":"sodium","range":"(1,0 – 200) mg/l"},{"name":"ammonium","range":"(0,05 – 10) mg/l"},{"name":"magnesium","range":"(1,0 – 100) mg/l"},{"name":"potassium","range":"(0,2 – 50) mg/l"},{"name":"calcium","range":"(5,0 – 150) mg/l"},{"name":"Total content of calcium and magnesium (total hardness) mg/l (calculated)"}],"search_en":"Water Cation concentrations: Ion chromatography (IC) lithium sodium ammonium magnesium potassium calcium Total content of calcium and magnesium (total hardness) mg/l (calculated) PN-EN ISO 14911:2002","technique_en":"Ion chromatography (IC)","test_object_en":"Water","search_zh":"水 阳离子浓度： 离子色谱法（IC） 铵态 PN-EN ISO 14911:2002","test_object_zh":"水","technique_zh":"离子色谱法（IC）","methodology_zh":"阳离子浓度：","parameters_zh":[{"name":"litowy","range":"(0,01 – 10) mg/l"},{"name":"sodowy","range":"(1,0 – 200) mg/l"},{"name":"铵态","range":"(0,05 – 10) mg/l"},{"name":"magnezowy","range":"(1,0 – 100) mg/l"},{"name":"potasowy","range":"(0,2 – 50) mg/l"},{"name":"wapniowy","range":"(5,0 – 150) mg/l"},{"name":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna) mg/l (z obliczeń)"}]},{"_id":"6a836a14af14b9c0e7b1df03","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie anionów","parameters":[{"name":"azotynowy","range":"(0,05 – 10) mg/l"},{"name":"azotanowy","range":"(0,1 – 50) mg/l"},{"name":"siarczanowy","range":"(0,25 – 250) mg/l"},{"name":"chlorkowy","range":"(0,25 – 250) mg/l"},{"name":"bromkowy","range":"(0,1 – 10) mg/l"},{"name":"fluorkowy","range":"(0,05 – 5) mg/l"}],"technique":"Metoda chromatografii jonowej (IC)","techniques":["Metoda chromatografii jonowej (IC)"],"computed":[],"activity":"Stężenie anionów\nZakres:\nazotynowy (0,05 – 10) mg/l\nazotanowy (0,1 – 50) mg/l\nsiarczanowy (0,25 – 250) mg/l\nchlorkowy (0,25 – 250) mg/l\nbromkowy (0,1 – 10) mg/l\nfluorkowy (0,05 – 5) mg/l\nMetoda chromatografii jonowej (IC)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie anionów\nZakres:\nazotynowy (0,05 – 10) mg/l\nazotanowy (0,1 – 50) mg/l\nsiarczanowy (0,25 – 250) mg/l\nchlorkowy (0,25 – 250) mg/l\nbromkowy (0,1 – 10) mg/l\nfluorkowy (0,05 – 5) mg/l\nMetoda chromatografii jonowej (IC) PN-EN ISO 10304-1:2009+AC:2012 Woda Stezenie anionow\nZakres:\nazotynowy (0,05 – 10) mg/l\nazotanowy (0,1 – 50) mg/l\nsiarczanowy (0,25 – 250) mg/l\nchlorkowy (0,25 – 250) mg/l\nbromkowy (0,1 – 10) mg/l\nfluorkowy (0,05 – 5) mg/l\nMetoda chromatografii jonowej (IC) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":112,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Anion concentrations","parameters_en":[{"name":"nitrite","range":"(0,05 – 10) mg/l"},{"name":"nitrate","range":"(0,1 – 50) mg/l"},{"name":"sulfate","range":"(0,25 – 250) mg/l"},{"name":"chloride","range":"(0,25 – 250) mg/l"},{"name":"bromide","range":"(0,1 – 10) mg/l"},{"name":"fluoride","range":"(0,05 – 5) mg/l"}],"search_en":"Water Anion concentrations Ion chromatography (IC) nitrite nitrate sulfate chloride bromide fluoride PN-EN ISO 10304-1:2009+AC:2012","technique_en":"Ion chromatography (IC)","test_object_en":"Water","methodology_zh":"阴离子浓度","search_zh":"水 阴离子浓度 离子色谱法（IC） PN-EN ISO 10304-1:2009+AC:2012","test_object_zh":"水","technique_zh":"离子色谱法（IC）"},{"_id":"6a836a14af14b9c0e7b1df04","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Chlor wolny","parameters":[{"name":"Zakres","range":"(0,02 – 2,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chlor wolny\nZakres (0,02 – 2,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7393-2:2018-04","norm_bases":["PN-EN ISO 7393-2:2018-04"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Chlor wolny\nZakres (0,02 – 2,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 7393-2:2018-04 Woda do spozycia przez ludzi Chlor wolny\nZakres (0,02 – 2,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 7393-2:2018-04","categories":["water"],"row_index":113,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free chlorine","parameters_en":[{"name":"Range","range":"(0,02 – 2,0) mg/l"}],"search_en":"Water intended for human consumption Free chlorine Spectrophotometric method Range PN-EN ISO 7393-2:2018-04","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,02 – 2,0) mg/l"}],"search_zh":"生活饮用水 游离氯 分光光度法 范围 PN-EN ISO 7393-2:2018-04","technique_zh":"分光光度法","test_object_zh":"生活饮用水","methodology_zh":"游离氯"},{"_id":"6a836a14af14b9c0e7b1df05","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Chlor wolny","parameters":[{"name":"Zakres","range":"(0,05 – 2,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chlor wolny\nZakres (0,05 – 2,0) mg/l\nMetoda spektrofotometryczna","reference":"Metoda Hach nr 8021 wydanie 2 z dnia 07/06/2017","norm_bases":["Metoda Hach nr 8021 wydanie 2 z dnia 07/06/2017"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin; Badania realizowane poza siedzibą laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Chlor wolny\nZakres (0,05 – 2,0) mg/l\nMetoda spektrofotometryczna Metoda Hach nr 8021 wydanie 2 z dnia 07/06/2017 Woda do spozycia przez ludzi Chlor wolny\nZakres (0,05 – 2,0) mg/l\nMetoda spektrofotometryczna Metoda Hach nr 8021 wydanie 2 z dnia 07/06/2017","categories":["water"],"row_index":114,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free chlorine","parameters_en":[{"name":"Range","range":"(0,05 – 2,0) mg/l"}],"search_en":"Water intended for human consumption Free chlorine Spectrophotometric method Range Metoda Hach nr 8021 wydanie 2 z dnia 07/06/2017","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,05 – 2,0) mg/l"}],"search_zh":"生活饮用水 游离氯 分光光度法 范围 Metoda Hach nr 8021 wydanie 2 z dnia 07/06/2017","technique_zh":"分光光度法","test_object_zh":"生活饮用水","methodology_zh":"游离氯"},{"_id":"6a836a14af14b9c0e7b1df06","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Zboża i przetwory zbożowe, Kawa, Owoce suszone","methodology":"Zawartość ochratoksyny A","parameters":[{"name":"Zakres","range":"(2,0 − 25) µg/kg"}],"technique":"Metoda immunoenzymatyczna (ELISA)","techniques":["Metoda immunoenzymatyczna (ELISA)"],"computed":[],"activity":"Zawartość ochratoksyny A\nZakres (2,0 − 25) µg/kg\nMetoda immunoenzymatyczna (ELISA)","reference":"PB/PACH/22B wydanie 2 z dnia 05.01.2021r. | metoda opracowana na podstawie instrukcji producenta testu diagnostycznego","norm_bases":["PB/PACH/22B wydanie 2 z dnia 05.01.2021r.","metoda opracowana na podstawie instrukcji producenta testu diagnostycznego"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Zboża i przetwory zbożowe, Kawa, Owoce suszone Zawartość ochratoksyny A\nZakres (2,0 − 25) µg/kg\nMetoda immunoenzymatyczna (ELISA) PB/PACH/22B wydanie 2 z dnia 05.01.2021r. | metoda opracowana na podstawie instrukcji producenta testu diagnostycznego Zboza i przetwory zbozowe, Kawa, Owoce suszone Zawartosc ochratoksyny A\nZakres (2,0 − 25) µg/kg\nMetoda immunoenzymatyczna (ELISA) PB/PACH/22B wydanie 2 z dnia 05.01.2021r. | metoda opracowana na podstawie instrukcji producenta testu diagnostycznego","categories":["other"],"row_index":115,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ochratoxin A content","parameters_en":[{"name":"Range","range":"(2,0 − 25) µg/kg"}],"search_en":"Cereals and cereal products, Coffee, Dried fruits Ochratoxin A content Enzyme immunoassay method (ELISA) Range PB/PACH/22B wydanie 2 z dnia 05.01.2021r. | metoda opracowana na podstawie instrukcji producenta testu diagnostycznego","technique_en":"Enzyme immunoassay method (ELISA)","test_object_en":"Cereals and cereal products, Coffee, Dried fruits","parameters_zh":[{"name":"范围","range":"(2,0 − 25) µg/kg"}],"search_zh":"赭曲霉毒素 A 含量 酶联免疫吸附法（ELISA） 范围 PB/PACH/22B wydanie 2 z dnia 05.01.2021r. | metoda opracowana na podstawie instrukcji producenta testu diagnostycznego","technique_zh":"酶联免疫吸附法（ELISA）","methodology_zh":"赭曲霉毒素 A 含量"},{"_id":"6a836a14af14b9c0e7b1df07","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Zboża i przetwory zbożowe","methodology":"Obecność szkodników zbożowo-mącznych i ich pozostałości","parameters":[],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Obecność szkodników zbożowo-mącznych i ich pozostałości\nMetoda wizualna","reference":"PN-74/A-74016","norm_bases":["PN-74/A-74016"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Zboża i przetwory zbożowe Obecność szkodników zbożowo-mącznych i ich pozostałości\nMetoda wizualna PN-74/A-74016 Zboza i przetwory zbozowe Obecnosc szkodnikow zbozowo-macznych i ich pozostalosci\nMetoda wizualna PN-74/A-74016","categories":["other"],"row_index":116,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Cereals and cereal products Visual method PN-74/A-74016","technique_en":"Visual method","test_object_en":"Cereals and cereal products","search_zh":"谷物与谷物制品 目视法 PN-74/A-74016","technique_zh":"目视法","test_object_zh":"谷物与谷物制品"},{"_id":"6a836a14af14b9c0e7b1df08","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Zboża i przetwory zbożowe","methodology":"Obecność szkodników zbożowo-mącznych i ich pozostałości","parameters":[],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Obecność szkodników zbożowo-mącznych i ich pozostałości\nMetoda wizualna","reference":"PN-93/A-74130 pkt 3.8.1","norm_bases":["PN-93/A-74130 pkt 3.8.1"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Zboża i przetwory zbożowe Obecność szkodników zbożowo-mącznych i ich pozostałości\nMetoda wizualna PN-93/A-74130 pkt 3.8.1 Zboza i przetwory zbozowe Obecnosc szkodnikow zbozowo-macznych i ich pozostalosci\nMetoda wizualna PN-93/A-74130 pkt 3.8.1","categories":["other"],"row_index":117,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Cereals and cereal products Visual method PN-93/A-74130 pkt 3.8.1","technique_en":"Visual method","test_object_en":"Cereals and cereal products","search_zh":"谷物与谷物制品 目视法 PN-93/A-74130 pkt 3.8.1","technique_zh":"目视法","test_object_zh":"谷物与谷物制品"},{"_id":"6a836a14af14b9c0e7b1df09","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Artykuły rolno-spożywcze E, Pasze","methodology":"Zawartość azotu","parameters":[{"name":"w przeliczeniu na białko/ białko surowe (z obliczeń)"}],"technique":"Metoda destylacyjno-miareczkowa","techniques":["Metoda destylacyjno-miareczkowa"],"computed":[],"activity":"Zawartość azotu\nw przeliczeniu na białko/ białko surowe (z obliczeń)\nMetoda destylacyjno-miareczkowa","reference":"Normy | PB/PACH/29 | Rozporządzenie Komisji (WE) Nr 152/2009","norm_bases":["Normy","PB/PACH/29","Rozporządzenie Komisji (WE) Nr 152/2009"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Artykuły rolno-spożywcze E, Pasze Zawartość azotu\nw przeliczeniu na białko/ białko surowe (z obliczeń)\nMetoda destylacyjno-miareczkowa Normy | PB/PACH/29 | Rozporządzenie Komisji (WE) Nr 152/2009 Artykuly rolno-spozywcze E, Pasze Zawartosc azotu\nw przeliczeniu na bialko/ bialko surowe (z obliczen)\nMetoda destylacyjno-miareczkowa Normy | PB/PACH/29 | Rozporzadzenie Komisji (WE) Nr 152/2009","categories":["food"],"row_index":118,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrogen content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Nitrogen content Distillation-titrimetric method E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy | PB/PACH/29 | Rozporządzenie Komisji (WE) Nr 152/2009","technique_en":"Distillation-titrimetric method","methodology_zh":"氮含量","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"氮含量 蒸馏-滴定法 E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy | PB/PACH/29 | Rozporządzenie Komisji (WE) Nr 152/2009","technique_zh":"蒸馏-滴定法"},{"_id":"6a836a14af14b9c0e7b1df0a","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Artykuły rolno-spożywcze E, Pasze","methodology":"Zawartość tłuszczu/ Zawartość tłuszczu wolnego/ tłuszczu w przeliczeniu na suchą masę, Zawartość tłuszczu wolnego/ tłuszczu po hydrolizie / tłuszczu w przeliczeniu na suchą masę/ tłuszczu surowego","parameters":[],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość tłuszczu/ Zawartość tłuszczu wolnego/ tłuszczu w przeliczeniu na suchą masę, Zawartość tłuszczu wolnego/ tłuszczu po hydrolizie / tłuszczu w przeliczeniu na suchą masę/ tłuszczu surowego\nMetoda wagowa","reference":"Normy | PB/PACH/07 | Rozporządzenie Komisji (WE) Nr 152/2009","norm_bases":["Normy","PB/PACH/07","Rozporządzenie Komisji (WE) Nr 152/2009"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Artykuły rolno-spożywcze E, Pasze Zawartość tłuszczu/ Zawartość tłuszczu wolnego/ tłuszczu w przeliczeniu na suchą masę, Zawartość tłuszczu wolnego/ tłuszczu po hydrolizie / tłuszczu w przeliczeniu na suchą masę/ tłuszczu surowego\nMetoda wagowa Normy | PB/PACH/07 | Rozporządzenie Komisji (WE) Nr 152/2009 Artykuly rolno-spozywcze E, Pasze Zawartosc tluszczu/ Zawartosc tluszczu wolnego/ tluszczu w przeliczeniu na sucha mase, Zawartosc tluszczu wolnego/ tluszczu po hydrolizie / tluszczu w przeliczeniu na sucha mase/ tluszczu surowego\nMetoda wagowa Normy | PB/PACH/07 | Rozporzadzenie Komisji (WE) Nr 152/2009","categories":["food"],"row_index":119,"parse_version":4,"parse_source":"agent-claude-code","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Gravimetric method E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy | PB/PACH/07 | Rozporządzenie Komisji (WE) Nr 152/2009","technique_en":"Gravimetric method","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"重量法 E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy | PB/PACH/07 | Rozporządzenie Komisji (WE) Nr 152/2009","technique_zh":"重量法"},{"_id":"6a836a14af14b9c0e7b1df0b","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Artykuły rolno-spożywcze E, Pasze","methodology":"Zawartość wody / suchej masy/ strata masy po suszeniu/ zawartość wody i substancji lotnych/ suchej pozostałości/ wilgotność","parameters":[],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wody / suchej masy/ strata masy po suszeniu/ zawartość wody i substancji lotnych/ suchej pozostałości/ wilgotność\nMetoda wagowa","reference":"Normy | Rozporządzenie Komisji (WE) Nr 152/2009","norm_bases":["Normy","Rozporządzenie Komisji (WE) Nr 152/2009"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Artykuły rolno-spożywcze E, Pasze Zawartość wody / suchej masy/ strata masy po suszeniu/ zawartość wody i substancji lotnych/ suchej pozostałości/ wilgotność\nMetoda wagowa Normy | Rozporządzenie Komisji (WE) Nr 152/2009 Artykuly rolno-spozywcze E, Pasze Zawartosc wody / suchej masy/ strata masy po suszeniu/ zawartosc wody i substancji lotnych/ suchej pozostalosci/ wilgotnosc\nMetoda wagowa Normy | Rozporzadzenie Komisji (WE) Nr 152/2009","categories":["water","food"],"row_index":120,"parse_version":4,"parse_source":"agent-claude-code","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Gravimetric method E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy | Rozporządzenie Komisji (WE) Nr 152/2009","technique_en":"Gravimetric method","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"重量法 E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy | Rozporządzenie Komisji (WE) Nr 152/2009","technique_zh":"重量法"},{"_id":"6a836a14af14b9c0e7b1df0c","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Artykuły rolno-spożywcze E, Pasze","methodology":"Zawartość popiołu/ popiołu całkowitego/ popiołu surowego","parameters":[],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość popiołu/ popiołu całkowitego/ popiołu surowego\nMetoda wagowa","reference":"Normy | PB/PACH/24 | Rozporządzenie Komisji (WE) Nr 152/2009","norm_bases":["Normy","PB/PACH/24","Rozporządzenie Komisji (WE) Nr 152/2009"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Artykuły rolno-spożywcze E, Pasze Zawartość popiołu/ popiołu całkowitego/ popiołu surowego\nMetoda wagowa Normy | PB/PACH/24 | Rozporządzenie Komisji (WE) Nr 152/2009 Artykuly rolno-spozywcze E, Pasze Zawartosc popiolu/ popiolu calkowitego/ popiolu surowego\nMetoda wagowa Normy | PB/PACH/24 | Rozporzadzenie Komisji (WE) Nr 152/2009","categories":["food"],"row_index":121,"parse_version":4,"parse_source":"agent-claude-code","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Gravimetric method E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy | PB/PACH/24 | Rozporządzenie Komisji (WE) Nr 152/2009","technique_en":"Gravimetric method","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"重量法 E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy | PB/PACH/24 | Rozporządzenie Komisji (WE) Nr 152/2009","technique_zh":"重量法"},{"_id":"6a836a14af14b9c0e7b1df0d","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Artykuły rolno-spożywcze E","methodology":"Zawartość popiołu nierozpuszczalnego w kwasie / zawartość zanieczyszczeń mineralnych nierozpuszczalnych w kwasie","parameters":[],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość popiołu nierozpuszczalnego w kwasie / zawartość zanieczyszczeń mineralnych nierozpuszczalnych w kwasie\nMetoda wagowa","reference":"Normy","norm_bases":["Normy"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Artykuły rolno-spożywcze E Zawartość popiołu nierozpuszczalnego w kwasie / zawartość zanieczyszczeń mineralnych nierozpuszczalnych w kwasie\nMetoda wagowa Normy Artykuly rolno-spozywcze E Zawartosc popiolu nierozpuszczalnego w kwasie / zawartosc zanieczyszczen mineralnych nierozpuszczalnych w kwasie\nMetoda wagowa Normy","categories":["other"],"row_index":122,"parse_version":4,"parse_source":"agent-claude-code","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Gravimetric method E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy","technique_en":"Gravimetric method","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"重量法 E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy","technique_zh":"重量法"},{"_id":"6a836a14af14b9c0e7b1df0e","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Artykuły rolno-spożywcze E, Pasze","methodology":"Masa netto / zawartość w opakowaniu jednostkowym","parameters":[{"name":"Udział % składników (z obliczeń)"}],"technique":"Metoda wagowa; Metoda wolumetryczna","techniques":["Metoda wagowa","Metoda wolumetryczna"],"computed":[],"activity":"Masa netto / zawartość w opakowaniu jednostkowym\nUdział % składników (z obliczeń)\nMetoda wagowa; Metoda wolumetryczna","reference":"Normy | PB/PACH/03","norm_bases":["Normy","PB/PACH/03"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Artykuły rolno-spożywcze E, Pasze Masa netto / zawartość w opakowaniu jednostkowym\nUdział % składników (z obliczeń)\nMetoda wagowa; Metoda wolumetryczna Normy | PB/PACH/03 Artykuly rolno-spozywcze E, Pasze Masa netto / zawartosc w opakowaniu jednostkowym\nUdzial % skladnikow (z obliczen)\nMetoda wagowa; Metoda wolumetryczna Normy | PB/PACH/03","categories":["food"],"row_index":123,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"% share of components (calculated)"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Gravimetric method; Volumetric method E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. % share of components (calculated) Normy | PB/PACH/03","technique_en":"Gravimetric method; Volumetric method","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy | PB/PACH/03"},{"_id":"6a836a14af14b9c0e7b1df0f","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Woda","methodology":"Zawartość w opakowaniu jednostkowym","parameters":[],"technique":"Metoda wolumetryczna","techniques":["Metoda wolumetryczna"],"computed":[],"activity":"Zawartość w opakowaniu jednostkowym\nMetoda wolumetryczna","reference":"PB/PACH/03","norm_bases":["PB/PACH/03"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Zawartość w opakowaniu jednostkowym\nMetoda wolumetryczna PB/PACH/03 Woda Zawartosc w opakowaniu jednostkowym\nMetoda wolumetryczna PB/PACH/03","categories":["water"],"row_index":124,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Water Volumetric method PB/PACH/03","technique_en":"Volumetric method","test_object_en":"Water","search_zh":"水 PB/PACH/03","test_object_zh":"水"},{"_id":"6a836a14af14b9c0e7b1df10","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Artykuły rolno-spożywcze E, Pasze","methodology":"Aktywność wody","parameters":[],"technique":"Metoda pomiaru punktu rosy","techniques":["Metoda pomiaru punktu rosy"],"computed":[],"activity":"Aktywność wody\nMetoda pomiaru punktu rosy","reference":"PN-ISO 21807","norm_bases":["PN-ISO 21807"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Artykuły rolno-spożywcze E, Pasze Aktywność wody\nMetoda pomiaru punktu rosy PN-ISO 21807 Artykuly rolno-spozywcze E, Pasze Aktywnosc wody\nMetoda pomiaru punktu rosy PN-ISO 21807","categories":["water","food"],"row_index":125,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water activity","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Water activity Dew point measurement method E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. PN-ISO 21807","technique_en":"Dew point measurement method","methodology_zh":"水分活度","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"水分活度 E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 PN-ISO 21807"},{"_id":"6a836a14af14b9c0e7b1df11","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Artykuły rolno-spożywcze E","methodology":"pH wyrobu/ pH roztworu","parameters":[],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH wyrobu/ pH roztworu\nMetoda potencjometryczna","reference":"Normy","norm_bases":["Normy"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Artykuły rolno-spożywcze E pH wyrobu/ pH roztworu\nMetoda potencjometryczna Normy Artykuly rolno-spozywcze E pH wyrobu/ pH roztworu\nMetoda potencjometryczna Normy","categories":["other"],"row_index":126,"parse_version":4,"parse_source":"agent-claude-code","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Potentiometric method E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy","technique_en":"Potentiometric method","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"电位法 E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy","technique_zh":"电位法"},{"_id":"6a836a14af14b9c0e7b1df12","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"pH","parameters":[{"name":"Zakres","range":"3,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 3,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523","norm_bases":["PN-EN ISO 10523"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi pH\nZakres 3,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523 Woda, woda do spozycia przez ludzi pH\nZakres 3,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523","categories":["water"],"row_index":127,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"3,0 – 10,0"}],"search_en":"Water, water intended for human consumption pH Potentiometric method Range PN-EN ISO 10523","technique_en":"Potentiometric method","test_object_en":"Water, water intended for human consumption","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"3,0 – 10,0"}],"search_zh":"水、生活饮用水 pH 值 电位法 范围 PN-EN ISO 10523","technique_zh":"电位法","test_object_zh":"水、生活饮用水"},{"_id":"6a836a14af14b9c0e7b1df13","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Artykuły rolno-spożywcze E, Pasze","methodology":"Zawartość pierwiastków","parameters":[],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Zawartość pierwiastków\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PB/PACH/04","norm_bases":["PB/PACH/04"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Artykuły rolno-spożywcze E, Pasze Zawartość pierwiastków\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB/PACH/04 Artykuly rolno-spozywcze E, Pasze Zawartosc pierwiastkow\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB/PACH/04","categories":["food"],"row_index":128,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Element content Flame atomic absorption spectrometry (FAAS) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. PB/PACH/04","technique_en":"Flame atomic absorption spectrometry (FAAS)","methodology_zh":"元素含量","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"元素含量 火焰原子吸收光谱法（FAAS） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 PB/PACH/04","technique_zh":"火焰原子吸收光谱法（FAAS）"},{"_id":"6a836a14af14b9c0e7b1df14","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Artykuły rolno-spożywcze E","methodology":"Zawartość błonnika pokarmowego","parameters":[],"technique":"Metoda enzymatyczna","techniques":["Metoda enzymatyczna"],"computed":[],"activity":"Zawartość błonnika pokarmowego\nMetoda enzymatyczna","reference":"AOAC 991.43","norm_bases":["AOAC 991.43"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Artykuły rolno-spożywcze E Zawartość błonnika pokarmowego\nMetoda enzymatyczna AOAC 991.43 Artykuly rolno-spozywcze E Zawartosc blonnika pokarmowego\nMetoda enzymatyczna AOAC 991.43","categories":["other"],"row_index":129,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dietary fibre content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Dietary fibre content Enzymatic method E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. AOAC 991.43","technique_en":"Enzymatic method","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"膳食纤维含量 酶法 E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 AOAC 991.43","methodology_zh":"膳食纤维含量","technique_zh":"酶法"},{"_id":"6a836a14af14b9c0e7b1df15","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Żywność E","methodology":"Cechy sensoryczne","parameters":[],"technique":"Prosty test opisowy","techniques":["Prosty test opisowy"],"computed":[],"activity":"Cechy sensoryczne\nProsty test opisowy","reference":"Normy","norm_bases":["Normy"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Cechy sensoryczne\nProsty test opisowy Normy Zywnosc E Cechy sensoryczne\nProsty test opisowy Normy","categories":["food"],"row_index":130,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sensory characteristics","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Food E Sensory characteristics Simple descriptive test E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Normy","technique_en":"Simple descriptive test","test_object_en":"Food E","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"食品 E 感官特性 E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 Normy","test_object_zh":"食品 E","methodology_zh":"感官特性"},{"_id":"6a836a14af14b9c0e7b1df16","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie pierwiastków","parameters":[],"technique":"Metoda spektrometrii mas z plazmą indukcyjnie sprzężoną (ICP-MS)","techniques":["Metoda spektrometrii mas z plazmą indukcyjnie sprzężoną (ICP-MS)"],"computed":[],"activity":"Stężenie pierwiastków\nMetoda spektrometrii mas z plazmą indukcyjnie sprzężoną (ICP-MS)","reference":"PN-EN ISO 17294-2","norm_bases":["PN-EN ISO 17294-2"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie pierwiastków\nMetoda spektrometrii mas z plazmą indukcyjnie sprzężoną (ICP-MS) PN-EN ISO 17294-2 Woda Stezenie pierwiastkow\nMetoda spektrometrii mas z plazma indukcyjnie sprzezona (ICP-MS) PN-EN ISO 17294-2","categories":["water"],"row_index":131,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element concentration","search_en":"Water Element concentration Inductively coupled plasma mass spectrometry (ICP-MS) PN-EN ISO 17294-2","technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","test_object_en":"Water","methodology_zh":"元素浓度","search_zh":"水 元素浓度 PN-EN ISO 17294-2","test_object_zh":"水"},{"_id":"6a836a14af14b9c0e7b1df17","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość i stężenie pierwiastków","parameters":[],"technique":"Metoda spektrometrii mas z plazmą indukcyjnie sprzężoną (ICP-MS)","techniques":["Metoda spektrometrii mas z plazmą indukcyjnie sprzężoną (ICP-MS)"],"computed":[],"activity":"Zawartość i stężenie pierwiastków\nMetoda spektrometrii mas z plazmą indukcyjnie sprzężoną (ICP-MS)","reference":"PB/PACH/41 | PN-EN 15763","norm_bases":["PB/PACH/41","PN-EN 15763"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Zawartość i stężenie pierwiastków\nMetoda spektrometrii mas z plazmą indukcyjnie sprzężoną (ICP-MS) PB/PACH/41 | PN-EN 15763 Zywnosc E Zawartosc i stezenie pierwiastkow\nMetoda spektrometrii mas z plazma indukcyjnie sprzezona (ICP-MS) PB/PACH/41 | PN-EN 15763","categories":["food"],"row_index":132,"parse_version":4,"parse_source":"agent-claude-code","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Food E Inductively coupled plasma mass spectrometry (ICP-MS) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. PB/PACH/41 | PN-EN 15763","technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","test_object_en":"Food E","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"食品 E E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 PB/PACH/41 | PN-EN 15763","test_object_zh":"食品 E"},{"_id":"6a836a14af14b9c0e7b1df18","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Pasze","methodology":"Zawartość pierwiastków","parameters":[],"technique":"Metoda spektrometrii mas z plazmą indukcyjnie sprzężoną (ICP-MS)","techniques":["Metoda spektrometrii mas z plazmą indukcyjnie sprzężoną (ICP-MS)"],"computed":[],"activity":"Zawartość pierwiastków\nMetoda spektrometrii mas z plazmą indukcyjnie sprzężoną (ICP-MS)","reference":"PN-EN 17053","norm_bases":["PN-EN 17053"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pasze Zawartość pierwiastków\nMetoda spektrometrii mas z plazmą indukcyjnie sprzężoną (ICP-MS) PN-EN 17053 Pasze Zawartosc pierwiastkow\nMetoda spektrometrii mas z plazma indukcyjnie sprzezona (ICP-MS) PN-EN 17053","categories":["food"],"row_index":133,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element content","search_en":"Feed Element content Inductively coupled plasma mass spectrometry (ICP-MS) PN-EN 17053","technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","test_object_en":"Feed","methodology_zh":"元素含量","search_zh":"饲料 元素含量 PN-EN 17053","test_object_zh":"饲料"},{"_id":"6a836a14af14b9c0e7b1df19","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Żywność E, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością E","methodology":"Zawartość białek alergennych","parameters":[],"technique":"Metoda immunoenzymatyczna (ELISA)","techniques":["Metoda immunoenzymatyczna (ELISA)"],"computed":[],"activity":"Zawartość białek alergennych\nMetoda immunoenzymatyczna (ELISA)","reference":"PN-EN 15633-1 | PB/PACH/39 | Instrukcje Producenta","norm_bases":["PN-EN 15633-1","PB/PACH/39","Instrukcje Producenta"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością E Zawartość białek alergennych\nMetoda immunoenzymatyczna (ELISA) PN-EN 15633-1 | PB/PACH/39 | Instrukcje Producenta Zywnosc E, Probki srodowiskowe z obszarow produkcji zywnosci i obrotu zywnoscia E Zawartosc bialek alergennych\nMetoda immunoenzymatyczna (ELISA) PN-EN 15633-1 | PB/PACH/39 | Instrukcje Producenta","categories":["food","environment"],"row_index":134,"parse_version":4,"parse_source":"agent-claude-code","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Food E, Environmental samples from food production and food trade areas E Enzyme immunoassay method (ELISA) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. PN-EN 15633-1 | PB/PACH/39 | Instrukcje Producenta","technique_en":"Enzyme immunoassay method (ELISA)","test_object_en":"Food E, Environmental samples from food production and food trade areas E","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"食品 E、来自食品生产与流通场所的环境样品 E 酶联免疫吸附法（ELISA） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 PN-EN 15633-1 | PB/PACH/39 | Instrukcje Producenta","technique_zh":"酶联免疫吸附法（ELISA）","test_object_zh":"食品 E、来自食品生产与流通场所的环境样品 E"},{"_id":"6a836a14af14b9c0e7b1df1a","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Próbki środowiskowe z obszarów produkcji E","methodology":"Obecność alergenów","parameters":[],"technique":"Metoda immunoenzymatyczna (ELISA)","techniques":["Metoda immunoenzymatyczna (ELISA)"],"computed":[],"activity":"Obecność alergenów\nMetoda immunoenzymatyczna (ELISA)","reference":"PB/PACH/40","norm_bases":["PB/PACH/40"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Próbki środowiskowe z obszarów produkcji E Obecność alergenów\nMetoda immunoenzymatyczna (ELISA) PB/PACH/40 Probki srodowiskowe z obszarow produkcji E Obecnosc alergenow\nMetoda immunoenzymatyczna (ELISA) PB/PACH/40","categories":["environment"],"row_index":135,"parse_version":4,"parse_source":"agent-claude-code","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Enzyme immunoassay method (ELISA) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. PB/PACH/40","technique_en":"Enzyme immunoassay method (ELISA)","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"酶联免疫吸附法（ELISA） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 PB/PACH/40","technique_zh":"酶联免疫吸附法（ELISA）"},{"_id":"6a836a14af14b9c0e7b1df1b","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Żywność E, Produkty rolne E","methodology":"Zawartość pozostałości środków ochrony roślin","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas LC-MS/MS","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas LC-MS/MS"],"computed":[],"activity":"Zawartość pozostałości środków ochrony roślin\nMetoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas LC-MS/MS","reference":"PN-EN 15662","norm_bases":["PN-EN 15662"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Produkty rolne E Zawartość pozostałości środków ochrony roślin\nMetoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas LC-MS/MS PN-EN 15662 Zywnosc E, Produkty rolne E Zawartosc pozostalosci srodkow ochrony roslin\nMetoda wysokosprawnej chromatografii cieczowej z detekcja tandemowa spektrometria mas LC-MS/MS PN-EN 15662","categories":["food"],"row_index":136,"parse_version":4,"parse_source":"agent-claude-code","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Food E, Agricultural products E High-performance liquid chromatography with tandem mass spectrometry detection LC-MS/MS E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. PN-EN 15662","technique_en":"High-performance liquid chromatography with tandem mass spectrometry detection LC-MS/MS","test_object_en":"Food E, Agricultural products E","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"食品 E、农产品 E 高效液相色谱-串联质谱检测法 LC-MS/MS E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 PN-EN 15662","test_object_zh":"食品 E、农产品 E","technique_zh":"高效液相色谱-串联质谱检测法 LC-MS/MS"},{"_id":"6a836a14af14b9c0e7b1df1c","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Żywność E, Produkty rolne E","methodology":"Zawartość pozostałości środków ochrony roślin","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas GC-MS/MS","techniques":["Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas GC-MS/MS"],"computed":[],"activity":"Zawartość pozostałości środków ochrony roślin\nMetoda chromatografii gazowej z detekcją tandemową spektrometrią mas GC-MS/MS","reference":"PN-EN 15662","norm_bases":["PN-EN 15662"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Produkty rolne E Zawartość pozostałości środków ochrony roślin\nMetoda chromatografii gazowej z detekcją tandemową spektrometrią mas GC-MS/MS PN-EN 15662 Zywnosc E, Produkty rolne E Zawartosc pozostalosci srodkow ochrony roslin\nMetoda chromatografii gazowej z detekcja tandemowa spektrometria mas GC-MS/MS PN-EN 15662","categories":["food"],"row_index":137,"parse_version":4,"parse_source":"agent-claude-code","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Food E, Agricultural products E Gas chromatography with tandem mass spectrometry detection GC-MS/MS E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. PN-EN 15662","technique_en":"Gas chromatography with tandem mass spectrometry detection GC-MS/MS","test_object_en":"Food E, Agricultural products E","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"食品 E、农产品 E E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 PN-EN 15662","test_object_zh":"食品 E、农产品 E"},{"_id":"6a836a14af14b9c0e7b1df1d","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość pozostałości środków ochrony roślin","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas LC-MS/MS","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas LC-MS/MS"],"computed":[],"activity":"Zawartość pozostałości środków ochrony roślin\nMetoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas LC-MS/MS","reference":"PB/PACH/44","norm_bases":["PB/PACH/44"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Zawartość pozostałości środków ochrony roślin\nMetoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas LC-MS/MS PB/PACH/44 Zywnosc E Zawartosc pozostalosci srodkow ochrony roslin\nMetoda wysokosprawnej chromatografii cieczowej z detekcja tandemowa spektrometria mas LC-MS/MS PB/PACH/44","categories":["food"],"row_index":138,"parse_version":4,"parse_source":"agent-claude-code","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Food E High-performance liquid chromatography with tandem mass spectrometry detection LC-MS/MS E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. PB/PACH/44","technique_en":"High-performance liquid chromatography with tandem mass spectrometry detection LC-MS/MS","test_object_en":"Food E","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"食品 E 高效液相色谱-串联质谱检测法 LC-MS/MS E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 PB/PACH/44","test_object_zh":"食品 E","technique_zh":"高效液相色谱-串联质谱检测法 LC-MS/MS"},{"_id":"6a836a14af14b9c0e7b1df1e","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość pozostałości środków ochrony roślin","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas GC-MS/MS","techniques":["Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas GC-MS/MS"],"computed":[],"activity":"Zawartość pozostałości środków ochrony roślin\nMetoda chromatografii gazowej z detekcją tandemową spektrometrią mas GC-MS/MS","reference":"PB/PACH/44","norm_bases":["PB/PACH/44"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Zawartość pozostałości środków ochrony roślin\nMetoda chromatografii gazowej z detekcją tandemową spektrometrią mas GC-MS/MS PB/PACH/44 Zywnosc E Zawartosc pozostalosci srodkow ochrony roslin\nMetoda chromatografii gazowej z detekcja tandemowa spektrometria mas GC-MS/MS PB/PACH/44","categories":["food"],"row_index":139,"parse_version":4,"parse_source":"agent-claude-code","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Food E Gas chromatography with tandem mass spectrometry detection GC-MS/MS E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. PB/PACH/44","technique_en":"Gas chromatography with tandem mass spectrometry detection GC-MS/MS","test_object_en":"Food E","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"食品 E E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 PB/PACH/44","test_object_zh":"食品 E"},{"_id":"6a836a14af14b9c0e7b1df1f","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Produkty rolne o wysokiej zawartości wody E RE)","methodology":"Zawartość pozostałości środków ochrony roślin","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas LC-MS/MS","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas LC-MS/MS"],"computed":[],"activity":"Zawartość pozostałości środków ochrony roślin\nMetoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas LC-MS/MS","reference":"PN-EN 15662","norm_bases":["PN-EN 15662"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot. RE) - Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów rozporządzenia (UE) nr 625/2017 Parlamentu Europejskiego i Rady z dnia 15 marca 2017 r. w sprawie kontroli urzędowych i innych czynności urzędowych przeprowadzanych w celu zapewnienia stosowania prawa żywnościowego i paszowego oraz zasad dotyczących zdrowia i dobrostanu zwierząt, zdrowia roślin i środków ochrony roślin (Dz. U. UE L 95/1 z 07.04.2017, z późn. zm.), rozporządzenia Parlamentu Europejskiego i Rady (UE) 2018/848 z dnia 30 maja 2018 roku w sprawie produkcji ekologicznej i znakowania produktów ekologicznych i uchylającego rozporządzenie Rady (WE) 834/2007 oraz dokumentu SANTE/11312/2021v2026.","flexible":false,"search_text":"Produkty rolne o wysokiej zawartości wody E RE) Zawartość pozostałości środków ochrony roślin\nMetoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas LC-MS/MS PN-EN 15662 Produkty rolne o wysokiej zawartosci wody E RE) Zawartosc pozostalosci srodkow ochrony roslin\nMetoda wysokosprawnej chromatografii cieczowej z detekcja tandemowa spektrometria mas LC-MS/MS PN-EN 15662","categories":["water"],"row_index":140,"parse_version":4,"parse_source":"agent-claude-code","search_en":"High-performance liquid chromatography with tandem mass spectrometry detection LC-MS/MS PN-EN 15662","technique_en":"High-performance liquid chromatography with tandem mass spectrometry detection LC-MS/MS","search_zh":"高效液相色谱-串联质谱检测法 LC-MS/MS PN-EN 15662","technique_zh":"高效液相色谱-串联质谱检测法 LC-MS/MS"},{"_id":"6a836a14af14b9c0e7b1df20","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Produkty rolne o wysokiej zawartości wody E RE)","methodology":"Zawartość pozostałości środków ochrony roślin","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas GC-MS/MS","techniques":["Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas GC-MS/MS"],"computed":[],"activity":"Zawartość pozostałości środków ochrony roślin\nMetoda chromatografii gazowej z detekcją tandemową spektrometrią mas GC-MS/MS","reference":"PN-EN 15662","norm_bases":["PN-EN 15662"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot. RE) - Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów rozporządzenia (UE) nr 625/2017 Parlamentu Europejskiego i Rady z dnia 15 marca 2017 r. w sprawie kontroli urzędowych i innych czynności urzędowych przeprowadzanych w celu zapewnienia stosowania prawa żywnościowego i paszowego oraz zasad dotyczących zdrowia i dobrostanu zwierząt, zdrowia roślin i środków ochrony roślin (Dz. U. UE L 95/1 z 07.04.2017, z późn. zm.), rozporządzenia Parlamentu Europejskiego i Rady (UE) 2018/848 z dnia 30 maja 2018 roku w sprawie produkcji ekologicznej i znakowania produktów ekologicznych i uchylającego rozporządzenie Rady (WE) 834/2007 oraz dokumentu SANTE/11312/2021v2026.","flexible":false,"search_text":"Produkty rolne o wysokiej zawartości wody E RE) Zawartość pozostałości środków ochrony roślin\nMetoda chromatografii gazowej z detekcją tandemową spektrometrią mas GC-MS/MS PN-EN 15662 Produkty rolne o wysokiej zawartosci wody E RE) Zawartosc pozostalosci srodkow ochrony roslin\nMetoda chromatografii gazowej z detekcja tandemowa spektrometria mas GC-MS/MS PN-EN 15662","categories":["water"],"row_index":141,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Gas chromatography with tandem mass spectrometry detection GC-MS/MS PN-EN 15662","technique_en":"Gas chromatography with tandem mass spectrometry detection GC-MS/MS"},{"_id":"6a836a14af14b9c0e7b1df21","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Produkty rolne o wysokiej zawartości wody E RE)","methodology":"Zawartość pozostałości środków ochrony roślin","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas LC-MS/MS","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas LC-MS/MS"],"computed":[],"activity":"Zawartość pozostałości środków ochrony roślin\nMetoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas LC-MS/MS","reference":"EURL-SRM QuPPe-PO-Method EURL-SRM","norm_bases":["EURL-SRM QuPPe-PO-Method EURL-SRM"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot. RE) - Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów rozporządzenia (UE) nr 625/2017 Parlamentu Europejskiego i Rady z dnia 15 marca 2017 r. w sprawie kontroli urzędowych i innych czynności urzędowych przeprowadzanych w celu zapewnienia stosowania prawa żywnościowego i paszowego oraz zasad dotyczących zdrowia i dobrostanu zwierząt, zdrowia roślin i środków ochrony roślin (Dz. U. UE L 95/1 z 07.04.2017, z późn. zm.), rozporządzenia Parlamentu Europejskiego i Rady (UE) 2018/848 z dnia 30 maja 2018 roku w sprawie produkcji ekologicznej i znakowania produktów ekologicznych i uchylającego rozporządzenie Rady (WE) 834/2007 oraz dokumentu SANTE/11312/2021v2026.","flexible":false,"search_text":"Produkty rolne o wysokiej zawartości wody E RE) Zawartość pozostałości środków ochrony roślin\nMetoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas LC-MS/MS EURL-SRM QuPPe-PO-Method EURL-SRM Produkty rolne o wysokiej zawartosci wody E RE) Zawartosc pozostalosci srodkow ochrony roslin\nMetoda wysokosprawnej chromatografii cieczowej z detekcja tandemowa spektrometria mas LC-MS/MS EURL-SRM QuPPe-PO-Method EURL-SRM","categories":["water"],"row_index":142,"parse_version":4,"parse_source":"agent-claude-code","search_en":"High-performance liquid chromatography with tandem mass spectrometry detection LC-MS/MS EURL-SRM QuPPe-PO-Method EURL-SRM","technique_en":"High-performance liquid chromatography with tandem mass spectrometry detection LC-MS/MS","search_zh":"高效液相色谱-串联质谱检测法 LC-MS/MS EURL-SRM QuPPe-PO-Method EURL-SRM","technique_zh":"高效液相色谱-串联质谱检测法 LC-MS/MS"},{"_id":"6a836a14af14b9c0e7b1df22","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Żywność E, Produkty rolne E","methodology":"Zawartość pozostałości środków ochrony roślin","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas LC-MS/MS","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas LC-MS/MS"],"computed":[],"activity":"Zawartość pozostałości środków ochrony roślin\nMetoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas LC-MS/MS","reference":"EURL-SRM QuPPe-PO-Method EURL-SRM","norm_bases":["EURL-SRM QuPPe-PO-Method EURL-SRM"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Produkty rolne E Zawartość pozostałości środków ochrony roślin\nMetoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas LC-MS/MS EURL-SRM QuPPe-PO-Method EURL-SRM Zywnosc E, Produkty rolne E Zawartosc pozostalosci srodkow ochrony roslin\nMetoda wysokosprawnej chromatografii cieczowej z detekcja tandemowa spektrometria mas LC-MS/MS EURL-SRM QuPPe-PO-Method EURL-SRM","categories":["food"],"row_index":143,"parse_version":4,"parse_source":"agent-claude-code","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Food E, Agricultural products E High-performance liquid chromatography with tandem mass spectrometry detection LC-MS/MS E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. EURL-SRM QuPPe-PO-Method EURL-SRM","technique_en":"High-performance liquid chromatography with tandem mass spectrometry detection LC-MS/MS","test_object_en":"Food E, Agricultural products E","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"食品 E、农产品 E 高效液相色谱-串联质谱检测法 LC-MS/MS E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 EURL-SRM QuPPe-PO-Method EURL-SRM","test_object_zh":"食品 E、农产品 E","technique_zh":"高效液相色谱-串联质谱检测法 LC-MS/MS"},{"_id":"6a836a14af14b9c0e7b1df23","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Żywność E, Pasze E","methodology":"Zawartość azotu","parameters":[{"name":"Zawartość białka (z obliczeń)"}],"technique":"Metoda spalania i pomiaru przy zastosowaniu detektora przewodności cieplnej (Dumas)","techniques":["Metoda spalania i pomiaru przy zastosowaniu detektora przewodności cieplnej (Dumas)"],"computed":[],"activity":"Zawartość azotu\nZawartość białka (z obliczeń)\nMetoda spalania i pomiaru przy zastosowaniu detektora przewodności cieplnej (Dumas)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze E Zawartość azotu\nZawartość białka (z obliczeń)\nMetoda spalania i pomiaru przy zastosowaniu detektora przewodności cieplnej (Dumas) Normy Zywnosc E, Pasze E Zawartosc azotu\nZawartosc bialka (z obliczen)\nMetoda spalania i pomiaru przy zastosowaniu detektora przewodnosci cieplnej (Dumas) Normy","categories":["food"],"row_index":144,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrogen content","parameters_en":[{"name":"Protein content (calculated)"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Food E, Feed E Nitrogen content Combustion and measurement method using a thermal conductivity detector (Dumas) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. Protein content (calculated) Normy","technique_en":"Combustion and measurement method using a thermal conductivity detector (Dumas)","test_object_en":"Food E, Feed E","methodology_zh":"氮含量","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"食品 E、饲料 E 氮含量 E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 蛋白质含量（计算值） Normy","parameters_zh":[{"name":"蛋白质含量（计算值）"}],"test_object_zh":"食品 E、饲料 E"},{"_id":"6a836a14af14b9c0e7b1df24","lab_id":"69ad52a3de79e566650fb1ed","country":"PL","accr_number":"AB 381","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość D-fruktozy","parameters":[{"name":"Zawartość D-glukozy"},{"name":"Zawartość sacharozy"},{"name":"Zawartość maltozy"},{"name":"Zawartość laktozy"},{"name":"Suma cukrów (cukry ogółem) Suma cukrów prostych (F+G)(z obliczeń)"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją RID refraktometryczną (HPLC-RID)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją RID refraktometryczną (HPLC-RID)"],"computed":[],"activity":"Zawartość D-fruktozy\nZakres:\nZawartość D-glukozy\nZawartość sacharozy\nZawartość maltozy\nZawartość laktozy\nSuma cukrów (cukry ogółem) Suma cukrów prostych (F+G)(z obliczeń)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją RID refraktometryczną (HPLC-RID)","reference":"PB/PACH/33","norm_bases":["PB/PACH/33"],"lab_section":"Pracownia Analiz Chemicznych; Helenów 6A, 09-500 Gostynin","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Zawartość D-fruktozy\nZakres:\nZawartość D-glukozy\nZawartość sacharozy\nZawartość maltozy\nZawartość laktozy\nSuma cukrów (cukry ogółem) Suma cukrów prostych (F+G)(z obliczeń)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją RID refraktometryczną (HPLC-RID) PB/PACH/33 Zywnosc E Zawartosc D-fruktozy\nZakres:\nZawartosc D-glukozy\nZawartosc sacharozy\nZawartosc maltozy\nZawartosc laktozy\nSuma cukrow (cukry ogolem) Suma cukrow prostych (F+G)(z obliczen)\nMetoda wysokosprawnej chromatografii cieczowej z detekcja RID refraktometryczna (HPLC-RID) PB/PACH/33","categories":["food"],"row_index":145,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"D-fructose content","parameters_en":[{"name":"D-glucose content"},{"name":"Sucrose content"},{"name":"Maltose content"},{"name":"Lactose content"},{"name":"Sum of sugars (total sugars) Sum of simple sugars (F+G)(calculated)"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Food E D-fructose content High-performance liquid chromatography with RID refractive index detection (HPLC-RID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. D-glucose content Sucrose content Maltose content Lactose content Sum of sugars (total sugars) Sum of simple sugars (F+G)(calculated) PB/PACH/33","technique_en":"High-performance liquid chromatography with RID refractive index detection (HPLC-RID)","test_object_en":"Food E","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"食品 E E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 蔗糖含量 乳糖含量 PB/PACH/33","test_object_zh":"食品 E","parameters_zh":[{"name":"Zawartość D-glukozy"},{"name":"蔗糖含量"},{"name":"Zawartość maltozy"},{"name":"乳糖含量"},{"name":"Suma cukrów (cukry ogółem) Suma cukrów prostych (F+G)(z obliczeń)"}]}],"has_pdf":true}