{"lab":{"_id":"69ad52a3de79e566650fb1d1","accr_number":"AB 342","country":"PL","accr_body":"PCA","address":"- WARSZAWSKI INSTYTUT TECHNOLOGICZNY, LABORATORIUM WŁAŚCIWOŚCI MECHANICZNYCH MATERIAŁÓW, ul. Duchnicka 3, 01-796 Warszawa","categories":["materials"],"city":"Warszawa","imported_at":"2026-03-08T10:42:43.265Z","methods_count":11,"name":"SIEĆ BADAWCZA ŁUKASIEWICZ","parse_status":"parsed","parse_version":3,"pdf_files":["AB_342.pdf"],"scope_summary":"","search_text":"sieć badawcza łukasiewicz - warszawski instytut technologiczny, laboratorium właściwości mechanicznych materiałów, ul. duchnicka 3, 01-796 warszawa materials other","status":"active","updated_at":"2026-03-08T14:51:11.223Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:11.223Z","location":{"type":"Point","coordinates":[21.0122,52.2297]},"email_confidence":"high","email_mx":true,"email_source":"https://wit.lukasiewicz.gov.pl/kontakt/","fields_of_testing":[{"codes":"J/8","pl":"Badania mechaniczne, badania metalograficzne wyrobów i materiałów konstrukcyjnych - w tym metali i kompozytów","en":"Mechanical tests, metallographic tests of construction products and materials – including metals and composite materials"}],"issue":{"no":"26","date":"04.09.2025"},"parse_date":"2026-07-20T07:09:34.421Z","parse_source":"script-pdfplumber","map_coord":[52.256758,20.968675],"map_geo":"nominatim-street","has_en":true,"category_counts":{"materials":9,"other":2},"category_scores":{"materials":7.36,"other":0.36},"has_zh":true},"methods":[{"_id":"6a5dc9aef1c10c8ce825ae68","lab_id":"69ad52a3de79e566650fb1d1","country":"PL","accr_number":"AB 342","accr_body":"PCA","test_object":"Stale, metale nieżelazne i ich stopy po różnych obróbkach, Śruby jednostronne i dwustronne","test_object_en":"Steels, non-ferrous metals and their alloys after various treatments, One-sided and double-ended bolts","methodology":"Własności mechaniczne:","methodology_en":"Mechanical properties:","parameters":[{"name":"Rp, Re, Rm, A, Z, F"},{"name":"Zakres obciążenia: max. 350 kN"},{"name":"Próba rozciągania w temperaturze pokojowej"}],"parameters_en":[{"name":"Rp, Re, Rm, A, Z, F"},{"name":"Load range: max. 350 kN"},{"name":"Tensile test at room temperature"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Własności mechaniczne:\nZakres:\nRp, Re, Rm, A, Z, F\nZakres obciążenia: max. 350 kN\nPróba rozciągania w temperaturze pokojowej","reference":"PN-EN ISO 6892-1:2020-05 metoda B * | PN-EN ISO 898-1:2013-06 | PN-EN ISO 3506-1:2020-10","norm_bases":["PN-EN ISO 6892-1:2020-05 metoda B *","PN-EN ISO 898-1:2013-06","PN-EN ISO 3506-1:2020-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stale, metale nieżelazne i ich stopy po różnych obróbkach, Śruby jednostronne i dwustronne Własności mechaniczne:\nZakres:\nRp, Re, Rm, A, Z, F\nZakres obciążenia: max. 350 kN\nPróba rozciągania w temperaturze pokojowej PN-EN ISO 6892-1:2020-05 metoda B * | PN-EN ISO 898-1:2013-06 | PN-EN ISO 3506-1:2020-10 Stale, metale niezelazne i ich stopy po roznych obrobkach, Sruby jednostronne i dwustronne Wlasnosci mechaniczne:\nZakres:\nRp, Re, Rm, A, Z, F\nZakres obciazenia: max. 350 kN\nProba rozciagania w temperaturze pokojowej PN-EN ISO 6892-1:2020-05 metoda B * | PN-EN ISO 898-1:2013-06 | PN-EN ISO 3506-1:2020-10","categories":["materials"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Steels, non-ferrous metals and their alloys after various treatments, One-sided and double-ended bolts Mechanical properties: Rp, Re, Rm, A, Z, F Load range: max. 350 kN Tensile test at room temperature PN-EN ISO 6892-1:2020-05 metoda B * | PN-EN ISO 898-1:2013-06 | PN-EN ISO 3506-1:2020-10","methodology_zh":"力学性能：","parameters_zh":[{"name":"Rp, Re, Rm, A, Z, F"},{"name":"Zakres obciążenia: max. 350 kN"},{"name":"室温拉伸试验"}],"search_zh":"力学性能： 室温拉伸试验 PN-EN ISO 6892-1:2020-05 metoda B * | PN-EN ISO 898-1:2013-06 | PN-EN ISO 3506-1:2020-10"},{"_id":"6a5dc9aef1c10c8ce825ae69","lab_id":"69ad52a3de79e566650fb1d1","country":"PL","accr_number":"AB 342","accr_body":"PCA","test_object":"Stale, metale nieżelazne i ich stopy po różnych obróbkach","test_object_en":"Steels, non-ferrous metals and their alloys after various treatments","methodology":"Podatność na odkształcenia plastyczne, Próba zginania","methodology_en":"Susceptibility to plastic deformation, Bend test","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Podatność na odkształcenia plastyczne, Próba zginania","reference":"PN-EN ISO 7438:2021-04 *","norm_bases":["PN-EN ISO 7438:2021-04 *"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stale, metale nieżelazne i ich stopy po różnych obróbkach Podatność na odkształcenia plastyczne, Próba zginania PN-EN ISO 7438:2021-04 * Stale, metale niezelazne i ich stopy po roznych obrobkach Podatnosc na odksztalcenia plastyczne, Proba zginania PN-EN ISO 7438:2021-04 *","categories":["materials"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Steels, non-ferrous metals and their alloys after various treatments Susceptibility to plastic deformation, Bend test PN-EN ISO 7438:2021-04 *","methodology_zh":"塑性变形敏感性，弯曲试验","search_zh":"塑性变形敏感性，弯曲试验 PN-EN ISO 7438:2021-04 *"},{"_id":"6a5dc9aef1c10c8ce825ae6a","lab_id":"69ad52a3de79e566650fb1d1","country":"PL","accr_number":"AB 342","accr_body":"PCA","test_object":"Stale, metale i ich stopy po różnych obróbkach oraz powłoki konwersyjne i galwaniczne","test_object_en":"Steels, metals and their alloys after various treatments and conversion and galvanic coatings","methodology":"Twardość HV","methodology_en":"HV hardness","parameters":[{"name":"Zakres","range":"HV 0,2, HV 0,5, HV1, HV5,"},{"name":"HV10, HV30"}],"parameters_en":[{"name":"Range","range":"HV 0,2, HV 0,5, HV1, HV5,"},{"name":"HV10, HV30"}],"technique":"Metoda Vickersa","techniques":["Metoda Vickersa"],"technique_en":"Vickers method","computed":[],"computed_en":[],"activity":"Twardość HV\nZakres:\nZakres HV 0,2, HV 0,5, HV1, HV5,\nHV10, HV30\nMetoda Vickersa","reference":"PN-EN ISO 6507-1:2024-04 *","norm_bases":["PN-EN ISO 6507-1:2024-04 *"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stale, metale i ich stopy po różnych obróbkach oraz powłoki konwersyjne i galwaniczne Twardość HV\nZakres:\nZakres HV 0,2, HV 0,5, HV1, HV5,\nHV10, HV30\nMetoda Vickersa PN-EN ISO 6507-1:2024-04 * Stale, metale i ich stopy po roznych obrobkach oraz powloki konwersyjne i galwaniczne Twardosc HV\nZakres:\nZakres HV 0,2, HV 0,5, HV1, HV5,\nHV10, HV30\nMetoda Vickersa PN-EN ISO 6507-1:2024-04 *","categories":["materials"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Steels, metals and their alloys after various treatments and conversion and galvanic coatings HV hardness Vickers method Range HV10, HV30 PN-EN ISO 6507-1:2024-04 *","parameters_zh":[{"name":"范围","range":"HV 0,2, HV 0,5, HV1, HV5,"},{"name":"HV10, HV30"}],"search_zh":"经各种处理的钢、金属及其合金以及转化膜与电镀涂层 维氏硬度 HV 维氏法 范围 PN-EN ISO 6507-1:2024-04 *","methodology_zh":"维氏硬度 HV","technique_zh":"维氏法","test_object_zh":"经各种处理的钢、金属及其合金以及转化膜与电镀涂层"},{"_id":"6a5dc9aef1c10c8ce825ae6b","lab_id":"69ad52a3de79e566650fb1d1","country":"PL","accr_number":"AB 342","accr_body":"PCA","test_object":"Stale, metale i ich stopy po różnych obróbkach oraz powłoki konwersyjne i galwaniczne","test_object_en":"Steels, metals and their alloys after various treatments and conversion and galvanic coatings","methodology":"Mikrotwardość μHV","methodology_en":"μHV microhardness","parameters":[{"name":"Zakres","range":"HV 0,05, HV 0,1"}],"parameters_en":[{"name":"Range","range":"HV 0,05, HV 0,1"}],"technique":"Metoda Vickersa","techniques":["Metoda Vickersa"],"technique_en":"Vickers method","computed":[],"computed_en":[],"activity":"Mikrotwardość μHV\nZakres HV 0,05, HV 0,1\nMetoda Vickersa","reference":"PN-EN ISO 6507-1:2024-04 *","norm_bases":["PN-EN ISO 6507-1:2024-04 *"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stale, metale i ich stopy po różnych obróbkach oraz powłoki konwersyjne i galwaniczne Mikrotwardość μHV\nZakres HV 0,05, HV 0,1\nMetoda Vickersa PN-EN ISO 6507-1:2024-04 * Stale, metale i ich stopy po roznych obrobkach oraz powloki konwersyjne i galwaniczne Mikrotwardosc μHV\nZakres HV 0,05, HV 0,1\nMetoda Vickersa PN-EN ISO 6507-1:2024-04 *","categories":["materials"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Steels, metals and their alloys after various treatments and conversion and galvanic coatings μHV microhardness Vickers method Range PN-EN ISO 6507-1:2024-04 *","parameters_zh":[{"name":"范围","range":"HV 0,05, HV 0,1"}],"search_zh":"经各种处理的钢、金属及其合金以及转化膜与电镀涂层 维氏法 范围 PN-EN ISO 6507-1:2024-04 *","technique_zh":"维氏法","test_object_zh":"经各种处理的钢、金属及其合金以及转化膜与电镀涂层"},{"_id":"6a5dc9aef1c10c8ce825ae6c","lab_id":"69ad52a3de79e566650fb1d1","country":"PL","accr_number":"AB 342","accr_body":"PCA","test_object":"Stale, metale i ich stopy po różnych obróbkach oraz powłoki konwersyjne i galwaniczne","test_object_en":"Steels, metals and their alloys after various treatments and conversion and galvanic coatings","methodology":"Twardość HRA, HRB, HRC","methodology_en":"Hardness HRA, HRB, HRC","parameters":[{"name":"Skala: A, B, C"}],"parameters_en":[{"name":"Scale: A, B, C"}],"technique":"Metoda Rockwella","techniques":["Metoda Rockwella"],"technique_en":"Rockwell method","computed":[],"computed_en":[],"activity":"Twardość HRA, HRB, HRC\nSkala: A, B, C\nMetoda Rockwella","reference":"PN-EN ISO 6508-1:2024-06 *","norm_bases":["PN-EN ISO 6508-1:2024-06 *"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stale, metale i ich stopy po różnych obróbkach oraz powłoki konwersyjne i galwaniczne Twardość HRA, HRB, HRC\nSkala: A, B, C\nMetoda Rockwella PN-EN ISO 6508-1:2024-06 * Stale, metale i ich stopy po roznych obrobkach oraz powloki konwersyjne i galwaniczne Twardosc HRA, HRB, HRC\nSkala: A, B, C\nMetoda Rockwella PN-EN ISO 6508-1:2024-06 *","categories":["materials"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Steels, metals and their alloys after various treatments and conversion and galvanic coatings Hardness HRA, HRB, HRC Rockwell method Scale: A, B, C PN-EN ISO 6508-1:2024-06 *","search_zh":"经各种处理的钢、金属及其合金以及转化膜与电镀涂层 洛氏法 PN-EN ISO 6508-1:2024-06 *","technique_zh":"洛氏法","test_object_zh":"经各种处理的钢、金属及其合金以及转化膜与电镀涂层"},{"_id":"6a5dc9aef1c10c8ce825ae6d","lab_id":"69ad52a3de79e566650fb1d1","country":"PL","accr_number":"AB 342","accr_body":"PCA","test_object":"Stale, metale i ich stopy po różnych obróbkach oraz powłoki konwersyjne i galwaniczne","test_object_en":"Steels, metals and their alloys after various treatments and conversion and galvanic coatings","methodology":"Twardość HBW","methodology_en":"HBW hardness","parameters":[{"name":"Zakres badania:"},{"name":"średnica kulek: 2,5 mm, 5 mm, 10 mm"}],"parameters_en":[{"name":"Test range:"},{"name":"ball diameter: 2,5 mm, 5 mm, 10 mm"}],"technique":"Metoda Brinella","techniques":["Metoda Brinella"],"technique_en":"Brinell method","computed":[],"computed_en":[],"activity":"Twardość HBW\nZakres:\nZakres badania:\nśrednica kulek: 2,5 mm, 5 mm, 10 mm\nMetoda Brinella","reference":"PN-EN ISO 6506-1:2014-12 *","norm_bases":["PN-EN ISO 6506-1:2014-12 *"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stale, metale i ich stopy po różnych obróbkach oraz powłoki konwersyjne i galwaniczne Twardość HBW\nZakres:\nZakres badania:\nśrednica kulek: 2,5 mm, 5 mm, 10 mm\nMetoda Brinella PN-EN ISO 6506-1:2014-12 * Stale, metale i ich stopy po roznych obrobkach oraz powloki konwersyjne i galwaniczne Twardosc HBW\nZakres:\nZakres badania:\nsrednica kulek: 2,5 mm, 5 mm, 10 mm\nMetoda Brinella PN-EN ISO 6506-1:2014-12 *","categories":["materials"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Steels, metals and their alloys after various treatments and conversion and galvanic coatings HBW hardness Brinell method Test range: ball diameter: 2,5 mm, 5 mm, 10 mm PN-EN ISO 6506-1:2014-12 *","methodology_zh":"布氏硬度 HBW","search_zh":"经各种处理的钢、金属及其合金以及转化膜与电镀涂层 布氏硬度 HBW 布氏法 PN-EN ISO 6506-1:2014-12 *","technique_zh":"布氏法","test_object_zh":"经各种处理的钢、金属及其合金以及转化膜与电镀涂层"},{"_id":"6a5dc9aef1c10c8ce825ae6e","lab_id":"69ad52a3de79e566650fb1d1","country":"PL","accr_number":"AB 342","accr_body":"PCA","test_object":"Wyroby hutnicze, bednarki, blachy","test_object_en":"Steel products, hoop steel, sheets","methodology":"Podatność na odkształcenia plastyczne","methodology_en":"Ability to undergo plastic deformation","parameters":[{"name":"grubości blachy:","range":"(0,2 ÷ 2) mm"},{"name":"Tłoczność metodą Erichsena"}],"parameters_en":[{"name":"sheet thickness:","range":"(0,2 ÷ 2) mm"},{"name":"Erichsen cupping test"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Podatność na odkształcenia plastyczne\nZakres:\ngrubości blachy: (0,2 ÷ 2) mm\nTłoczność metodą Erichsena","reference":"PN-EN ISO 20482:2014 *","norm_bases":["PN-EN ISO 20482:2014 *"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby hutnicze, bednarki, blachy Podatność na odkształcenia plastyczne\nZakres:\ngrubości blachy: (0,2 ÷ 2) mm\nTłoczność metodą Erichsena PN-EN ISO 20482:2014 * Wyroby hutnicze, bednarki, blachy Podatnosc na odksztalcenia plastyczne\nZakres:\ngrubosci blachy: (0,2 ÷ 2) mm\nTlocznosc metoda Erichsena PN-EN ISO 20482:2014 *","categories":["other"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Steel products, hoop steel, sheets Ability to undergo plastic deformation sheet thickness: Erichsen cupping test PN-EN ISO 20482:2014 *"},{"_id":"6a5dc9aef1c10c8ce825ae6f","lab_id":"69ad52a3de79e566650fb1d1","country":"PL","accr_number":"AB 342","accr_body":"PCA","test_object":"Metale, stopy metali, Warstwy dyfuzyjne, powłoki","test_object_en":"Metals, metal alloys, Diffusion layers, coatings","methodology":"Mikrostruktura, Jakościowa i ilościowa analiza składników struktury","methodology_en":"Microstructure, Qualitative and quantitative analysis of structural constituents","parameters":[],"parameters_en":[],"technique":"Metoda mikroskopii optycznej","techniques":["Metoda mikroskopii optycznej"],"technique_en":"Optical microscopy method","computed":[],"computed_en":[],"activity":"Mikrostruktura, Jakościowa i ilościowa analiza składników struktury\nMetoda mikroskopii optycznej","reference":"PB/1/AB342, edycja 10 z dn. 05.05.2025 r.","norm_bases":["PB/1/AB342, edycja 10 z dn. 05.05.2025 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Metale, stopy metali, Warstwy dyfuzyjne, powłoki Mikrostruktura, Jakościowa i ilościowa analiza składników struktury\nMetoda mikroskopii optycznej PB/1/AB342, edycja 10 z dn. 05.05.2025 r. Metale, stopy metali, Warstwy dyfuzyjne, powloki Mikrostruktura, Jakosciowa i ilosciowa analiza skladnikow struktury\nMetoda mikroskopii optycznej PB/1/AB342, edycja 10 z dn. 05.05.2025 r.","categories":["materials"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Metals, metal alloys, Diffusion layers, coatings Microstructure, Qualitative and quantitative analysis of structural constituents Optical microscopy method PB/1/AB342, edycja 10 z dn. 05.05.2025 r.","search_zh":"光学显微镜法 PB/1/AB342, edycja 10 z dn. 05.05.2025 r.","technique_zh":"光学显微镜法"},{"_id":"6a5dc9aef1c10c8ce825ae70","lab_id":"69ad52a3de79e566650fb1d1","country":"PL","accr_number":"AB 342","accr_body":"PCA","test_object":"Stale niestopowe i niskostopowe","test_object_en":"Non-alloy and low-alloy steels","methodology":"Głębokość odwęglenia","methodology_en":"Decarburisation depth","parameters":[],"parameters_en":[],"technique":"Metoda metalograficzna","techniques":["Metoda metalograficzna"],"technique_en":"Metallographic method","computed":[],"computed_en":[],"activity":"Głębokość odwęglenia\nMetoda metalograficzna","reference":"PN-EN ISO 3887:2024-04 *","norm_bases":["PN-EN ISO 3887:2024-04 *"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stale niestopowe i niskostopowe Głębokość odwęglenia\nMetoda metalograficzna PN-EN ISO 3887:2024-04 * Stale niestopowe i niskostopowe Glebokosc odweglenia\nMetoda metalograficzna PN-EN ISO 3887:2024-04 *","categories":["materials"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Non-alloy and low-alloy steels Decarburisation depth Metallographic method PN-EN ISO 3887:2024-04 *","search_zh":"脱碳层深度 金相法 PN-EN ISO 3887:2024-04 *","technique_zh":"金相法","methodology_zh":"脱碳层深度"},{"_id":"6a5dc9aef1c10c8ce825ae71","lab_id":"69ad52a3de79e566650fb1d1","country":"PL","accr_number":"AB 342","accr_body":"PCA","test_object":"Powłoki metalowe i tlenkowe","test_object_en":"Metallic and oxide coatings","methodology":"Grubość powłoki","methodology_en":"Coating thickness","parameters":[],"parameters_en":[],"technique":"Metoda mikroskopii optycznej","techniques":["Metoda mikroskopii optycznej"],"technique_en":"Optical microscopy method","computed":[],"computed_en":[],"activity":"Grubość powłoki\nMetoda mikroskopii optycznej","reference":"PN-EN ISO 1463:2021-10 *","norm_bases":["PN-EN ISO 1463:2021-10 *"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Powłoki metalowe i tlenkowe Grubość powłoki\nMetoda mikroskopii optycznej PN-EN ISO 1463:2021-10 * Powloki metalowe i tlenkowe Grubosc powloki\nMetoda mikroskopii optycznej PN-EN ISO 1463:2021-10 *","categories":["materials"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Metallic and oxide coatings Coating thickness Optical microscopy method PN-EN ISO 1463:2021-10 *","search_zh":"涂层厚度 光学显微镜法 PN-EN ISO 1463:2021-10 *","technique_zh":"光学显微镜法","methodology_zh":"涂层厚度"},{"_id":"6a5dc9aef1c10c8ce825ae72","lab_id":"69ad52a3de79e566650fb1d1","country":"PL","accr_number":"AB 342","accr_body":"PCA","test_object":"Warstwa utwardzona powierzchniowo","test_object_en":"Surface-hardened layer","methodology":"Grubość warstwy","methodology_en":"Layer thickness","parameters":[{"name":"Zakres","range":"HV 0,2; HV 0,5; HV 1"}],"parameters_en":[{"name":"Range","range":"HV 0,2; HV 0,5; HV 1"}],"technique":"Metoda Vickersa","techniques":["Metoda Vickersa"],"technique_en":"Vickers method","computed":[],"computed_en":[],"activity":"Grubość warstwy\nZakres HV 0,2; HV 0,5; HV 1\nMetoda Vickersa","reference":"PN-EN ISO 18203:2022-09 * | PN-EN ISO 6507-1:2024-04","norm_bases":["PN-EN ISO 18203:2022-09 *","PN-EN ISO 6507-1:2024-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Warstwa utwardzona powierzchniowo Grubość warstwy\nZakres HV 0,2; HV 0,5; HV 1\nMetoda Vickersa PN-EN ISO 18203:2022-09 * | PN-EN ISO 6507-1:2024-04 Warstwa utwardzona powierzchniowo Grubosc warstwy\nZakres HV 0,2; HV 0,5; HV 1\nMetoda Vickersa PN-EN ISO 18203:2022-09 * | PN-EN ISO 6507-1:2024-04","categories":["other"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Surface-hardened layer Layer thickness Vickers method Range PN-EN ISO 18203:2022-09 * | PN-EN ISO 6507-1:2024-04","parameters_zh":[{"name":"范围","range":"HV 0,2; HV 0,5; HV 1"}],"search_zh":"层厚 维氏法 范围 PN-EN ISO 18203:2022-09 * | PN-EN ISO 6507-1:2024-04","technique_zh":"维氏法","methodology_zh":"层厚"}],"has_pdf":true}