{"lab":{"_id":"69ad52a3de79e566650fb1cf","accr_number":"AB 340","country":"PL","accr_body":"PCA","address":"TRANSPORTOWO-HANDLOWO-USŁUGOWE „BIELASZKA”, CENTRALNE LABORATORIUM DS. BADAŃ ŚRODOWISKA PRACY, „STANISŁAW BIELASZKA”, ul. Pszczyńska 8","categories":["environment","automotive"],"city":"Jastrzębie Zdrój","imported_at":"2026-03-08T10:42:43.265Z","methods_count":110,"name":"STANISŁAW BIELASZKA PRZEDSIĘBIORSTWO","parse_status":"parsed","parse_version":3,"pdf_files":["AB_340.pdf"],"scope_summary":"","search_text":"stanisław bielaszka przedsiębiorstwo transportowo-handlowo-usługowe „bielaszka”, centralne laboratorium ds. badań środowiska pracy, „stanisław bielaszka”, ul. pszczyńska 8 environment metrology other pharma electronics materials automotive food petro construction","status":"active","updated_at":"2026-03-08T14:51:11.178Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-20T00:35:43.674Z","email_confidence":"high","email_mx":true,"email_source":"https://www.pca.gov.pl/akredytowane-podmioty/akredytacje-aktywne/laboratoria-badawcze/AB%20340,podmiot.html","fields_of_testing":[{"codes":"C/33/P","pl":"Badania chemiczne i pobieranie próbek – środowisko pracy (czynniki szkodliwe - powietrze)","en":"Chemical tests and sampling - working environment (harmful factors - air)"},{"codes":"G/33 – G/34 – N/33/P","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki szkodliwe i uciążliwe – hałas, drgania, nielaserowe promieniowanie optyczne, mikroklimat, pole elektromagnetyczne)","en":"Tests concerning environmental engineering (environmental and climatic) - working environment (harmful and nuisance factors noise, vibration, non-laser optical radiation, microclimate, electromagnetic field)"}],"issue":{"no":"32","date":"18.08.2026"},"parse_date":"2026-08-20T00:35:43.674Z","parse_source":"agent-claude-code","map_coord":[49.954891,18.576908],"map_geo":"nominatim-street","has_en":true,"lab_locations":[{"name":"Pracownia Zagrożeń Fizycznych","address":"ul. Pszczyńska 8, 44-330 Jastrzębie Zdrój","city":"Jastrzębie Zdrój","postal":"44-330"},{"name":"Pracownia Zagrożeń Chemicznych i Pyłowych","address":"ul. Pszczyńska 8, 44-330 Jastrzębie Zdrój","city":"Jastrzębie Zdrój","postal":"44-330"}],"scope_format":"PCA::pracownie+siatka5","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/19/e22f556bdfe3f5f1a95bb1e6e3f6da9b/AB%20340.pdf","category_counts":{"environment":110,"automotive":5,"electronics":4,"materials":4,"construction":2,"petro":1},"category_scores":{"environment":96.03,"automotive":0.2,"electronics":0.13,"materials":0.13,"construction":0.03,"petro":0.01},"has_zh":true},"methods":[{"_id":"6a864bdffbf98dd0af9b1e8f","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – hałas","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(22 – 135) dB"},{"name":"Szczytowy poziom dźwięku C"},{"name":"Zakres","range":"(35 – 138) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (22 – 135) dB\nSzczytowy poziom dźwięku C\nZakres (35 – 138) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 i strategię 3 - punkt 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 i strategię 3 - punkt 11"],"lab_section":"Pracownia Zagrożeń Fizycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (22 – 135) dB\nSzczytowy poziom dźwięku C\nZakres (35 – 138) dB\nMetoda pomiarowa bezpośrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 i strategię 3 - punkt 11 Srodowisko pracy – halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A\nZakres:\nZakres (22 – 135) dB\nSzczytowy poziom dzwieku C\nZakres (35 – 138) dB\nMetoda pomiarowa bezposrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie 2 - punkt 10 i strategie 3 - punkt 11","categories":["environment"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"A 计权等效声级 A 计权最大声级","parameters_zh":[{"name":"范围","range":"(22 – 135) dB"},{"name":"C 计权峰值声级"},{"name":"范围","range":"(35 – 138) dB"}],"search_zh":"工作场所环境 — 噪声 A 计权等效声级 A 计权最大声级 直接测量法 范围 C 计权峰值声级 范围 PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 i strategię 3 - punkt 11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a864bdffbf98dd0af9b1e90","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – hałas","methodology":"Poziom ekspozycji na hałas odniesiony do:","parameters":[{"name":"8-godz. dobowego wymiaru czasu pracy"},{"name":"przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 i strategię 3 - punkt 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 i strategię 3 - punkt 11"],"lab_section":"Pracownia Zagrożeń Fizycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – hałas Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 i strategię 3 - punkt 11 Srodowisko pracy – halas Poziom ekspozycji na halas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzecietnego tygodniowego wymiaru czasu pracy (z obliczen) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie 2 - punkt 10 i strategie 3 - punkt 11","categories":["environment"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"噪声暴露级，参照：","parameters_zh":[{"name":"8 小时日工作时间"},{"name":"平均每周工作时间（计算值）"}],"search_zh":"工作场所环境 — 噪声 噪声暴露级，参照： 8 小时日工作时间 平均每周工作时间（计算值） PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 i strategię 3 - punkt 11","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a864bdffbf98dd0af9b1e91","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A,","parameters":[{"name":"Zakres","range":"(22 – 135) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A,\nZakres (22 – 135) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F","norm_bases":["Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F"],"lab_section":"Pracownia Zagrożeń Fizycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A,\nZakres (22 – 135) dB\nMetoda pomiarowa bezpośrednia Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F Srodowisko ogolne – halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A,\nZakres (22 – 135) dB\nMetoda pomiarowa bezposrednia Zalacznik nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wylaczeniem punktu F","categories":["environment"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(22 – 135) dB"}],"search_zh":"一般环境 – 来自设施、设备与工业企业的噪声 A 计权等效声级， 直接测量法 范围 Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F","technique_zh":"直接测量法","test_object_zh":"一般环境 – 来自设施、设备与工业企业的噪声","methodology_zh":"A 计权等效声级，"},{"_id":"6a864bdffbf98dd0af9b1e92","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F","norm_bases":["Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F"],"lab_section":"Pracownia Zagrożeń Fizycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F Srodowisko ogolne – halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen) Zalacznik nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wylaczeniem punktu F","categories":["environment"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境 – 来自设施、设备与工业企业的噪声 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值） Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F","test_object_zh":"一般环境 – 来自设施、设备与工业企业的噪声"},{"_id":"6a864bdffbf98dd0af9b1e93","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","parameters":[{"name":"Zakres","range":"(0,01 – 50) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,01 – 50) m/s2\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-2:2004/A1:2015-11"],"lab_section":"Pracownia Zagrożeń Fizycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,01 – 50) m/s2\nMetoda pomiarowa bezpośrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 Srodowisko pracy – drgania dzialajace na organizm czlowieka przez konczyny gorne Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres (0,01 – 50) m/s2\nMetoda pomiarowa bezposrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","categories":["environment"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"频率计权振动加速度有效值","parameters_zh":[{"name":"范围","range":"(0,01 – 50) m/s2"}],"search_zh":"工作场所环境 — 手传振动 频率计权振动加速度有效值 直接测量法 范围 PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 手传振动"},{"_id":"6a864bdffbf98dd0af9b1e94","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-2:2004/A1:2015-11"],"lab_section":"Pracownia Zagrożeń Fizycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 Srodowisko pracy – drgania dzialajace na organizm czlowieka przez konczyny gorne Ekspozycja dzienna, wyrazona w postaci rownowaznej energetycznie dla 8-godzin dzialania sumy wektorowej skutecznych, skorygowanych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci sumy wektorowej skutecznych, wazonych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz) (z obliczen) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","categories":["environment"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","search_zh":"工作场所环境 — 手传振动 日暴露量，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值矢量和的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值的矢量和表示（计算值） PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","test_object_zh":"工作场所环境 — 手传振动","methodology_zh":"日暴露量，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值矢量和的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值的矢量和表示（计算值）"},{"_id":"6a864bdffbf98dd0af9b1e95","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","parameters":[{"name":"Zakres","range":"(0,01 – 50) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,01 – 50) m/s2\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":"Pracownia Zagrożeń Fizycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,01 – 50) m/s2\nMetoda pomiarowa bezpośrednia PN-EN 14253+A1:2011 Srodowisko pracy – drgania o ogolnym dzialaniu na organizm czlowieka Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres (0,01 – 50) m/s2\nMetoda pomiarowa bezposrednia PN-EN 14253+A1:2011","categories":["environment"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"频率计权振动加速度有效值","parameters_zh":[{"name":"范围","range":"(0,01 – 50) m/s2"}],"search_zh":"工作场所环境 — 全身振动 频率计权振动加速度有效值 直接测量法 范围 PN-EN 14253+A1:2011","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 全身振动"},{"_id":"6a864bdffbf98dd0af9b1e96","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń)","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":"Pracownia Zagrożeń Fizycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń) PN-EN 14253+A1:2011 Srodowisko pracy – drgania o ogolnym dzialaniu na organizm czlowieka Ekspozycja dzienna, wyrazona w postaci rownowaznego energetycznie dla 8-godzin dzialania skutecznego, skorygowanego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1.4awx, 1.4awy, awz), Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci skutecznego, wazonego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1.4awx, 1.4awy, awz) (z obliczen) PN-EN 14253+A1:2011","categories":["environment"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","search_zh":"工作场所环境 — 全身振动 日暴露量，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值表示（计算值） PN-EN 14253+A1:2011","test_object_zh":"工作场所环境 — 全身振动","methodology_zh":"日暴露量，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值表示（计算值）"},{"_id":"6a864bdffbf98dd0af9b1e97","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne od instalacji i urządzeń przemysłowych: - urządzenia do spawania łukowego - zgrzewarki rezystancyjne - przemysłowe magnetyzery i demagnetyzatory - instalacje elektrolityczne - urządzenia do grzania dielektrycznego - urządzenia do grzania indukcyjnego - przemysłowe piece, nagrzewnice i suszarki mikrofalowe - urządzenia do wytwarzania i przetwarzania tworzyw sztucznych - pojazdy elektryczne - urządzenia do lutowania - elektrodrążarki - piece oporowe i łukowe - generatory i silniki elektryczne - falowniki","methodology":"Natężenie pola elektrycznego w zakresie częstotliwości: od 5 Hz do 400 kHz","parameters":[{"name":"Zakres","range":"(1,05V/m – 49,45 kV/m)"},{"name":"od 0,1 MHz","range":"do 3 GHz"},{"name":"Zakres","range":"(0,5 – 989) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego w zakresie częstotliwości: od 5 Hz do 400 kHz\nZakres:\nZakres (1,05V/m – 49,45 kV/m)\nod 0,1 MHz do 3 GHz\nZakres (0,5 – 989) V/m\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB-PZF-PEM-1 wyd. 1 z dn. 14.05.2025","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","PB-PZF-PEM-1 wyd. 1 z dn. 14.05.2025"],"lab_section":"Pracownia Zagrożeń Fizycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne od instalacji i urządzeń przemysłowych: - urządzenia do spawania łukowego - zgrzewarki rezystancyjne - przemysłowe magnetyzery i demagnetyzatory - instalacje elektrolityczne - urządzenia do grzania dielektrycznego - urządzenia do grzania indukcyjnego - przemysłowe piece, nagrzewnice i suszarki mikrofalowe - urządzenia do wytwarzania i przetwarzania tworzyw sztucznych - pojazdy elektryczne - urządzenia do lutowania - elektrodrążarki - piece oporowe i łukowe - generatory i silniki elektryczne - falowniki Natężenie pola elektrycznego w zakresie częstotliwości: od 5 Hz do 400 kHz\nZakres:\nZakres (1,05V/m – 49,45 kV/m)\nod 0,1 MHz do 3 GHz\nZakres (0,5 – 989) V/m\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB-PZF-PEM-1 wyd. 1 z dn. 14.05.2025 Srodowisko pracy - pole elektromagnetyczne od instalacji i urzadzen przemyslowych: - urzadzenia do spawania lukowego - zgrzewarki rezystancyjne - przemyslowe magnetyzery i demagnetyzatory - instalacje elektrolityczne - urzadzenia do grzania dielektrycznego - urzadzenia do grzania indukcyjnego - przemyslowe piece, nagrzewnice i suszarki mikrofalowe - urzadzenia do wytwarzania i przetwarzania tworzyw sztucznych - pojazdy elektryczne - urzadzenia do lutowania - elektrodrazarki - piece oporowe i lukowe - generatory i silniki elektryczne - falowniki Natezenie pola elektrycznego w zakresie czestotliwosci: od 5 Hz do 400 kHz\nZakres:\nZakres (1,05V/m – 49,45 kV/m)\nod 0,1 MHz do 3 GHz\nZakres (0,5 – 989) V/m\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB-PZF-PEM-1 wyd. 1 z dn. 14.05.2025","categories":["environment","automotive"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(1,05V/m – 49,45 kV/m)"},{"name":"od 0,1 MHz","range":"do 3 GHz"},{"name":"范围","range":"(0,5 – 989) V/m"}],"search_zh":"工作环境 － 来自工业装置与设备的电磁场：－ 弧焊设备 － 电阻焊机 － 工业充磁与退磁装置 － 电解装置 － 介电加热设备 直接测量法 范围 范围 PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB-PZF-PEM-1 wyd. 1 z dn. 14.05.2025","technique_zh":"直接测量法","test_object_zh":"工作环境 － 来自工业装置与设备的电磁场：－ 弧焊设备 － 电阻焊机 － 工业充磁与退磁装置 － 电解装置 － 介电加热设备"},{"_id":"6a864bdffbf98dd0af9b1e98","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne od instalacji i urządzeń przemysłowych: - urządzenia do spawania łukowego - zgrzewarki rezystancyjne - przemysłowe magnetyzery i demagnetyzatory - instalacje elektrolityczne - urządzenia do grzania dielektrycznego - urządzenia do grzania indukcyjnego - przemysłowe piece, nagrzewnice i suszarki mikrofalowe - urządzenia do wytwarzania i przetwarzania tworzyw sztucznych - pojazdy elektryczne - urządzenia do lutowania - elektrodrążarki - piece oporowe i łukowe - generatory i silniki elektryczne - falowniki","methodology":"Natężenie pola magnetycznego w zakresie częstotliwości: od 0,3 MHz do 30 MHz","parameters":[{"name":"Zakres","range":"(0,012 – 16,14) A/m"},{"name":"od 27 MHz","range":"do 1 GHz"},{"name":"Zakres","range":"(0,01 – 10,88) A/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola magnetycznego w zakresie częstotliwości: od 0,3 MHz do 30 MHz\nZakres:\nZakres (0,012 – 16,14) A/m\nod 27 MHz do 1 GHz\nZakres (0,01 – 10,88) A/m\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB-PZF-PEM-1 wyd. 1 z dn. 14.05.2025","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","PB-PZF-PEM-1 wyd. 1 z dn. 14.05.2025"],"lab_section":"Pracownia Zagrożeń Fizycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne od instalacji i urządzeń przemysłowych: - urządzenia do spawania łukowego - zgrzewarki rezystancyjne - przemysłowe magnetyzery i demagnetyzatory - instalacje elektrolityczne - urządzenia do grzania dielektrycznego - urządzenia do grzania indukcyjnego - przemysłowe piece, nagrzewnice i suszarki mikrofalowe - urządzenia do wytwarzania i przetwarzania tworzyw sztucznych - pojazdy elektryczne - urządzenia do lutowania - elektrodrążarki - piece oporowe i łukowe - generatory i silniki elektryczne - falowniki Natężenie pola magnetycznego w zakresie częstotliwości: od 0,3 MHz do 30 MHz\nZakres:\nZakres (0,012 – 16,14) A/m\nod 27 MHz do 1 GHz\nZakres (0,01 – 10,88) A/m\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB-PZF-PEM-1 wyd. 1 z dn. 14.05.2025 Srodowisko pracy - pole elektromagnetyczne od instalacji i urzadzen przemyslowych: - urzadzenia do spawania lukowego - zgrzewarki rezystancyjne - przemyslowe magnetyzery i demagnetyzatory - instalacje elektrolityczne - urzadzenia do grzania dielektrycznego - urzadzenia do grzania indukcyjnego - przemyslowe piece, nagrzewnice i suszarki mikrofalowe - urzadzenia do wytwarzania i przetwarzania tworzyw sztucznych - pojazdy elektryczne - urzadzenia do lutowania - elektrodrazarki - piece oporowe i lukowe - generatory i silniki elektryczne - falowniki Natezenie pola magnetycznego w zakresie czestotliwosci: od 0,3 MHz do 30 MHz\nZakres:\nZakres (0,012 – 16,14) A/m\nod 27 MHz do 1 GHz\nZakres (0,01 – 10,88) A/m\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB-PZF-PEM-1 wyd. 1 z dn. 14.05.2025","categories":["environment","automotive"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,012 – 16,14) A/m"},{"name":"自 27 MHz 起","range":"do 1 GHz"},{"name":"范围","range":"(0,01 – 10,88) A/m"}],"search_zh":"工作环境 － 来自工业装置与设备的电磁场：－ 弧焊设备 － 电阻焊机 － 工业充磁与退磁装置 － 电解装置 － 介电加热设备 直接测量法 范围 自 27 MHz 起 范围 PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB-PZF-PEM-1 wyd. 1 z dn. 14.05.2025","technique_zh":"直接测量法","test_object_zh":"工作环境 － 来自工业装置与设备的电磁场：－ 弧焊设备 － 电阻焊机 － 工业充磁与退磁装置 － 电解装置 － 介电加热设备"},{"_id":"6a864bdffbf98dd0af9b1e99","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne od instalacji i urządzeń przemysłowych: - urządzenia do spawania łukowego - zgrzewarki rezystancyjne - przemysłowe magnetyzery i demagnetyzatory - instalacje elektrolityczne - urządzenia do grzania dielektrycznego - urządzenia do grzania indukcyjnego - przemysłowe piece, nagrzewnice i suszarki mikrofalowe - urządzenia do wytwarzania i przetwarzania tworzyw sztucznych - pojazdy elektryczne - urządzenia do lutowania - elektrodrążarki - piece oporowe i łukowe - generatory i silniki elektryczne - falowniki","methodology":"Indukcja magnetyczna w zakresie częstotliwości: 0 Hz","parameters":[{"name":"Zakres","range":"(0,20 – 1024) mT"},{"name":"od 5 Hz","range":"do 400 kHz"},{"name":"Zakres","range":"(0,019– 19,12 μT)"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Indukcja magnetyczna w zakresie częstotliwości: 0 Hz\nZakres:\nZakres (0,20 – 1024) mT\nod 5 Hz do 400 kHz\nZakres (0,019– 19,12 μT)\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB-PZF-PEM-1 wyd. 1 z dn. 14.05.2025","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","PB-PZF-PEM-1 wyd. 1 z dn. 14.05.2025"],"lab_section":"Pracownia Zagrożeń Fizycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne od instalacji i urządzeń przemysłowych: - urządzenia do spawania łukowego - zgrzewarki rezystancyjne - przemysłowe magnetyzery i demagnetyzatory - instalacje elektrolityczne - urządzenia do grzania dielektrycznego - urządzenia do grzania indukcyjnego - przemysłowe piece, nagrzewnice i suszarki mikrofalowe - urządzenia do wytwarzania i przetwarzania tworzyw sztucznych - pojazdy elektryczne - urządzenia do lutowania - elektrodrążarki - piece oporowe i łukowe - generatory i silniki elektryczne - falowniki Indukcja magnetyczna w zakresie częstotliwości: 0 Hz\nZakres:\nZakres (0,20 – 1024) mT\nod 5 Hz do 400 kHz\nZakres (0,019– 19,12 μT)\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB-PZF-PEM-1 wyd. 1 z dn. 14.05.2025 Srodowisko pracy - pole elektromagnetyczne od instalacji i urzadzen przemyslowych: - urzadzenia do spawania lukowego - zgrzewarki rezystancyjne - przemyslowe magnetyzery i demagnetyzatory - instalacje elektrolityczne - urzadzenia do grzania dielektrycznego - urzadzenia do grzania indukcyjnego - przemyslowe piece, nagrzewnice i suszarki mikrofalowe - urzadzenia do wytwarzania i przetwarzania tworzyw sztucznych - pojazdy elektryczne - urzadzenia do lutowania - elektrodrazarki - piece oporowe i lukowe - generatory i silniki elektryczne - falowniki Indukcja magnetyczna w zakresie czestotliwosci: 0 Hz\nZakres:\nZakres (0,20 – 1024) mT\nod 5 Hz do 400 kHz\nZakres (0,019– 19,12 μT)\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB-PZF-PEM-1 wyd. 1 z dn. 14.05.2025","categories":["environment","automotive"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,20 – 1024) mT"},{"name":"od 5 Hz","range":"do 400 kHz"},{"name":"范围","range":"(0,019– 19,12 μT)"}],"search_zh":"工作环境 － 来自工业装置与设备的电磁场：－ 弧焊设备 － 电阻焊机 － 工业充磁与退磁装置 － 电解装置 － 介电加热设备 直接测量法 范围 范围 PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB-PZF-PEM-1 wyd. 1 z dn. 14.05.2025","technique_zh":"直接测量法","test_object_zh":"工作环境 － 来自工业装置与设备的电磁场：－ 弧焊设备 － 电阻焊机 － 工业充磁与退磁装置 － 电解装置 － 介电加热设备"},{"_id":"6a864bdffbf98dd0af9b1e9a","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne od instalacji i urządzeń przemysłowych: - urządzenia do spawania łukowego - zgrzewarki rezystancyjne - przemysłowe magnetyzery i demagnetyzatory - instalacje elektrolityczne - urządzenia do grzania dielektrycznego - urządzenia do grzania indukcyjnego - przemysłowe piece, nagrzewnice i suszarki mikrofalowe - urządzenia do wytwarzania i przetwarzania tworzyw sztucznych - pojazdy elektryczne - urządzenia do lutowania - elektrodrążarki - piece oporowe i łukowe - generatory i silniki elektryczne - falowniki","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości: 0Hz od 5 Hz","range":"do 400 kHz"},{"name":"od 800 MHz","range":"do 3 GHz"},{"name":"(z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości: 0Hz od 5 Hz do 400 kHz\nod 800 MHz do 3 GHz\n(z obliczeń)","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB-PZF-PEM-1 wyd. 1 z dn. 14.05.2025","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","PB-PZF-PEM-1 wyd. 1 z dn. 14.05.2025"],"lab_section":"Pracownia Zagrożeń Fizycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne od instalacji i urządzeń przemysłowych: - urządzenia do spawania łukowego - zgrzewarki rezystancyjne - przemysłowe magnetyzery i demagnetyzatory - instalacje elektrolityczne - urządzenia do grzania dielektrycznego - urządzenia do grzania indukcyjnego - przemysłowe piece, nagrzewnice i suszarki mikrofalowe - urządzenia do wytwarzania i przetwarzania tworzyw sztucznych - pojazdy elektryczne - urządzenia do lutowania - elektrodrążarki - piece oporowe i łukowe - generatory i silniki elektryczne - falowniki Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości: 0Hz od 5 Hz do 400 kHz\nod 800 MHz do 3 GHz\n(z obliczeń) PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB-PZF-PEM-1 wyd. 1 z dn. 14.05.2025 Srodowisko pracy - pole elektromagnetyczne od instalacji i urzadzen przemyslowych: - urzadzenia do spawania lukowego - zgrzewarki rezystancyjne - przemyslowe magnetyzery i demagnetyzatory - instalacje elektrolityczne - urzadzenia do grzania dielektrycznego - urzadzenia do grzania indukcyjnego - przemyslowe piece, nagrzewnice i suszarki mikrofalowe - urzadzenia do wytwarzania i przetwarzania tworzyw sztucznych - pojazdy elektryczne - urzadzenia do lutowania - elektrodrazarki - piece oporowe i lukowe - generatory i silniki elektryczne - falowniki Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci: 0Hz od 5 Hz do 400 kHz\nod 800 MHz do 3 GHz\n(z obliczen) PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB-PZF-PEM-1 wyd. 1 z dn. 14.05.2025","categories":["environment","automotive"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"磁场强度：","parameters_zh":[{"name":"w zakresie częstotliwości: 0Hz od 5 Hz","range":"do 400 kHz"},{"name":"od 800 MHz","range":"do 3 GHz"},{"name":"（计算得出）"}],"search_zh":"工作环境 － 来自工业装置与设备的电磁场：－ 弧焊设备 － 电阻焊机 － 工业充磁与退磁装置 － 电解装置 － 介电加热设备 磁场强度： （计算得出） PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB-PZF-PEM-1 wyd. 1 z dn. 14.05.2025","test_object_zh":"工作环境 － 来自工业装置与设备的电磁场：－ 弧焊设备 － 电阻焊机 － 工业充磁与退磁装置 － 电解装置 － 介电加热设备"},{"_id":"6a864bdffbf98dd0af9b1e9b","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne pochodzące od systemów radiokomunikacyjnych i antykradzieżowych - radiotelefony doręczne, terminale i urządzenia bezprzewodowe krótkiego zasięgu, radiostacje (radiotelefony) nasobne i przewoźne - systemy antykradzieżowe oraz elektronicznej kontroli obiektów","methodology":"Natężenie pola elektrycznego w zakresie częstotliwości: od 5 Hz do 400 kHz","parameters":[{"name":"Zakres","range":"(1,05V/m – 49,45 kV/m)"},{"name":"od 0,1 MHz","range":"do 3 GHz"},{"name":"Zakres","range":"(0,5 – 989) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego w zakresie częstotliwości: od 5 Hz do 400 kHz\nZakres:\nZakres (1,05V/m – 49,45 kV/m)\nod 0,1 MHz do 3 GHz\nZakres (0,5 – 989) V/m\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB-PZF-PEM-3 wyd. 1 z dn. 14.05.2025","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","PB-PZF-PEM-3 wyd. 1 z dn. 14.05.2025"],"lab_section":"Pracownia Zagrożeń Fizycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne pochodzące od systemów radiokomunikacyjnych i antykradzieżowych - radiotelefony doręczne, terminale i urządzenia bezprzewodowe krótkiego zasięgu, radiostacje (radiotelefony) nasobne i przewoźne - systemy antykradzieżowe oraz elektronicznej kontroli obiektów Natężenie pola elektrycznego w zakresie częstotliwości: od 5 Hz do 400 kHz\nZakres:\nZakres (1,05V/m – 49,45 kV/m)\nod 0,1 MHz do 3 GHz\nZakres (0,5 – 989) V/m\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB-PZF-PEM-3 wyd. 1 z dn. 14.05.2025 Srodowisko pracy - pole elektromagnetyczne pochodzace od systemow radiokomunikacyjnych i antykradziezowych - radiotelefony doreczne, terminale i urzadzenia bezprzewodowe krotkiego zasiegu, radiostacje (radiotelefony) nasobne i przewozne - systemy antykradziezowe oraz elektronicznej kontroli obiektow Natezenie pola elektrycznego w zakresie czestotliwosci: od 5 Hz do 400 kHz\nZakres:\nZakres (1,05V/m – 49,45 kV/m)\nod 0,1 MHz do 3 GHz\nZakres (0,5 – 989) V/m\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB-PZF-PEM-3 wyd. 1 z dn. 14.05.2025","categories":["environment","electronics"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(1,05V/m – 49,45 kV/m)"},{"name":"od 0,1 MHz","range":"do 3 GHz"},{"name":"范围","range":"(0,5 – 989) V/m"}],"search_zh":"工作环境 － 无线电通信与防盗系统产生的电磁场 － 手持对讲机、终端与短距离无线设备、随身与车载电台（对讲机） － 防盗系统 直接测量法 范围 范围 PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB-PZF-PEM-3 wyd. 1 z dn. 14.05.2025","technique_zh":"直接测量法","test_object_zh":"工作环境 － 无线电通信与防盗系统产生的电磁场 － 手持对讲机、终端与短距离无线设备、随身与车载电台（对讲机） － 防盗系统"},{"_id":"6a864bdffbf98dd0af9b1e9c","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne pochodzące od systemów radiokomunikacyjnych i antykradzieżowych - radiotelefony doręczne, terminale i urządzenia bezprzewodowe krótkiego zasięgu, radiostacje (radiotelefony) nasobne i przewoźne - systemy antykradzieżowe oraz elektronicznej kontroli obiektów","methodology":"Natężenie pola magnetycznego w zakresie częstotliwości: od 0,3 MHz do 30 MHz","parameters":[{"name":"Zakres","range":"(0,012 – 16,14) A/m"},{"name":"od 27 MHz","range":"do 1 GHz"},{"name":"Zakres","range":"(0,01 – 10,88) A/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola magnetycznego w zakresie częstotliwości: od 0,3 MHz do 30 MHz\nZakres:\nZakres (0,012 – 16,14) A/m\nod 27 MHz do 1 GHz\nZakres (0,01 – 10,88) A/m\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB-PZF-PEM-3 wyd. 1 z dn. 14.05.2025","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","PB-PZF-PEM-3 wyd. 1 z dn. 14.05.2025"],"lab_section":"Pracownia Zagrożeń Fizycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne pochodzące od systemów radiokomunikacyjnych i antykradzieżowych - radiotelefony doręczne, terminale i urządzenia bezprzewodowe krótkiego zasięgu, radiostacje (radiotelefony) nasobne i przewoźne - systemy antykradzieżowe oraz elektronicznej kontroli obiektów Natężenie pola magnetycznego w zakresie częstotliwości: od 0,3 MHz do 30 MHz\nZakres:\nZakres (0,012 – 16,14) A/m\nod 27 MHz do 1 GHz\nZakres (0,01 – 10,88) A/m\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB-PZF-PEM-3 wyd. 1 z dn. 14.05.2025 Srodowisko pracy - pole elektromagnetyczne pochodzace od systemow radiokomunikacyjnych i antykradziezowych - radiotelefony doreczne, terminale i urzadzenia bezprzewodowe krotkiego zasiegu, radiostacje (radiotelefony) nasobne i przewozne - systemy antykradziezowe oraz elektronicznej kontroli obiektow Natezenie pola magnetycznego w zakresie czestotliwosci: od 0,3 MHz do 30 MHz\nZakres:\nZakres (0,012 – 16,14) A/m\nod 27 MHz do 1 GHz\nZakres (0,01 – 10,88) A/m\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB-PZF-PEM-3 wyd. 1 z dn. 14.05.2025","categories":["environment","electronics"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,012 – 16,14) A/m"},{"name":"自 27 MHz 起","range":"do 1 GHz"},{"name":"范围","range":"(0,01 – 10,88) A/m"}],"search_zh":"工作环境 － 无线电通信与防盗系统产生的电磁场 － 手持对讲机、终端与短距离无线设备、随身与车载电台（对讲机） － 防盗系统 直接测量法 范围 自 27 MHz 起 范围 PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB-PZF-PEM-3 wyd. 1 z dn. 14.05.2025","technique_zh":"直接测量法","test_object_zh":"工作环境 － 无线电通信与防盗系统产生的电磁场 － 手持对讲机、终端与短距离无线设备、随身与车载电台（对讲机） － 防盗系统"},{"_id":"6a864bdffbf98dd0af9b1e9d","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne pochodzące od systemów radiokomunikacyjnych i antykradzieżowych - radiotelefony doręczne, terminale i urządzenia bezprzewodowe krótkiego zasięgu, radiostacje (radiotelefony) nasobne i przewoźne - systemy antykradzieżowe oraz elektronicznej kontroli obiektów","methodology":"Indukcja magnetyczna w zakresie częstotliwości: od 5 Hz do 400 kHz","parameters":[{"name":"Zakres","range":"(0,019– 19,12 μT)"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Indukcja magnetyczna w zakresie częstotliwości: od 5 Hz do 400 kHz\nZakres (0,019– 19,12 μT)\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB-PZF-PEM-3 wyd. 1 z dn. 14.05.2025","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","PB-PZF-PEM-3 wyd. 1 z dn. 14.05.2025"],"lab_section":"Pracownia Zagrożeń Fizycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne pochodzące od systemów radiokomunikacyjnych i antykradzieżowych - radiotelefony doręczne, terminale i urządzenia bezprzewodowe krótkiego zasięgu, radiostacje (radiotelefony) nasobne i przewoźne - systemy antykradzieżowe oraz elektronicznej kontroli obiektów Indukcja magnetyczna w zakresie częstotliwości: od 5 Hz do 400 kHz\nZakres (0,019– 19,12 μT)\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB-PZF-PEM-3 wyd. 1 z dn. 14.05.2025 Srodowisko pracy - pole elektromagnetyczne pochodzace od systemow radiokomunikacyjnych i antykradziezowych - radiotelefony doreczne, terminale i urzadzenia bezprzewodowe krotkiego zasiegu, radiostacje (radiotelefony) nasobne i przewozne - systemy antykradziezowe oraz elektronicznej kontroli obiektow Indukcja magnetyczna w zakresie czestotliwosci: od 5 Hz do 400 kHz\nZakres (0,019– 19,12 μT)\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB-PZF-PEM-3 wyd. 1 z dn. 14.05.2025","categories":["environment","electronics"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,019– 19,12 μT)"}],"search_zh":"工作环境 － 无线电通信与防盗系统产生的电磁场 － 手持对讲机、终端与短距离无线设备、随身与车载电台（对讲机） － 防盗系统 直接测量法 范围 PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB-PZF-PEM-3 wyd. 1 z dn. 14.05.2025","technique_zh":"直接测量法","test_object_zh":"工作环境 － 无线电通信与防盗系统产生的电磁场 － 手持对讲机、终端与短距离无线设备、随身与车载电台（对讲机） － 防盗系统"},{"_id":"6a864bdffbf98dd0af9b1e9e","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne pochodzące od systemów radiokomunikacyjnych i antykradzieżowych - radiotelefony doręczne, terminale i urządzenia bezprzewodowe krótkiego zasięgu, radiostacje (radiotelefony) nasobne i przewoźne - systemy antykradzieżowe oraz elektronicznej kontroli obiektów","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości: od 5 Hz","range":"do 400 kHz"},{"name":"od 800 MHz","range":"do 3 GHz"},{"name":"(z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości: od 5 Hz do 400 kHz\nod 800 MHz do 3 GHz\n(z obliczeń)","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB-PZF-PEM-3 wyd. 1 z dn. 14.05.2025","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","PB-PZF-PEM-3 wyd. 1 z dn. 14.05.2025"],"lab_section":"Pracownia Zagrożeń Fizycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne pochodzące od systemów radiokomunikacyjnych i antykradzieżowych - radiotelefony doręczne, terminale i urządzenia bezprzewodowe krótkiego zasięgu, radiostacje (radiotelefony) nasobne i przewoźne - systemy antykradzieżowe oraz elektronicznej kontroli obiektów Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości: od 5 Hz do 400 kHz\nod 800 MHz do 3 GHz\n(z obliczeń) PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB-PZF-PEM-3 wyd. 1 z dn. 14.05.2025 Srodowisko pracy - pole elektromagnetyczne pochodzace od systemow radiokomunikacyjnych i antykradziezowych - radiotelefony doreczne, terminale i urzadzenia bezprzewodowe krotkiego zasiegu, radiostacje (radiotelefony) nasobne i przewozne - systemy antykradziezowe oraz elektronicznej kontroli obiektow Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci: od 5 Hz do 400 kHz\nod 800 MHz do 3 GHz\n(z obliczen) PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB-PZF-PEM-3 wyd. 1 z dn. 14.05.2025","categories":["environment","electronics"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"磁场强度：","parameters_zh":[{"name":"w zakresie częstotliwości: od 5 Hz","range":"do 400 kHz"},{"name":"od 800 MHz","range":"do 3 GHz"},{"name":"（计算得出）"}],"search_zh":"工作环境 － 无线电通信与防盗系统产生的电磁场 － 手持对讲机、终端与短距离无线设备、随身与车载电台（对讲机） － 防盗系统 磁场强度： （计算得出） PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB-PZF-PEM-3 wyd. 1 z dn. 14.05.2025","test_object_zh":"工作环境 － 无线电通信与防盗系统产生的电磁场 － 手持对讲机、终端与短距离无线设备、随身与车载电台（对讲机） － 防盗系统"},{"_id":"6a864bdffbf98dd0af9b1e9f","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne pochodzące od urządzeń stosowanych w technice medycznej - diatermie chirurgiczne - diatermie fizykoterapeutyczne skanery rezonansu magnetycznego","methodology":"Natężenie pola elektrycznego w zakresie częstotliwości: od 0,1 MHz do 3 GHz","parameters":[{"name":"Zakres","range":"(0,5 – 989) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego w zakresie częstotliwości: od 0,1 MHz do 3 GHz\nZakres (0,5 – 989) V/m\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB-PZF-PEM-2 wyd. 1 z dn. 14.05.2025","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","PB-PZF-PEM-2 wyd. 1 z dn. 14.05.2025"],"lab_section":"Pracownia Zagrożeń Fizycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne pochodzące od urządzeń stosowanych w technice medycznej - diatermie chirurgiczne - diatermie fizykoterapeutyczne skanery rezonansu magnetycznego Natężenie pola elektrycznego w zakresie częstotliwości: od 0,1 MHz do 3 GHz\nZakres (0,5 – 989) V/m\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB-PZF-PEM-2 wyd. 1 z dn. 14.05.2025 Srodowisko pracy - pole elektromagnetyczne pochodzace od urzadzen stosowanych w technice medycznej - diatermie chirurgiczne - diatermie fizykoterapeutyczne skanery rezonansu magnetycznego Natezenie pola elektrycznego w zakresie czestotliwosci: od 0,1 MHz do 3 GHz\nZakres (0,5 – 989) V/m\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB-PZF-PEM-2 wyd. 1 z dn. 14.05.2025","categories":["environment"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,5 – 989) V/m"}],"search_zh":"工作环境 － 医疗技术设备产生的电磁场 － 外科电刀 － 理疗透热治疗仪 － 磁共振扫描仪 直接测量法 范围 PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB-PZF-PEM-2 wyd. 1 z dn. 14.05.2025","technique_zh":"直接测量法","test_object_zh":"工作环境 － 医疗技术设备产生的电磁场 － 外科电刀 － 理疗透热治疗仪 － 磁共振扫描仪"},{"_id":"6a864bdffbf98dd0af9b1ea0","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne pochodzące od urządzeń stosowanych w technice medycznej - diatermie chirurgiczne - diatermie fizykoterapeutyczne skanery rezonansu magnetycznego","methodology":"Natężenie pola magnetycznego w zakresie częstotliwości: od 0,3 MHz do 30 MHz","parameters":[{"name":"Zakres","range":"(0,012 – 16,14) A/m"},{"name":"od 27 MHz","range":"do 1 GHz"},{"name":"Zakres","range":"(0,01 – 10,88) A/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola magnetycznego w zakresie częstotliwości: od 0,3 MHz do 30 MHz\nZakres:\nZakres (0,012 – 16,14) A/m\nod 27 MHz do 1 GHz\nZakres (0,01 – 10,88) A/m\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB-PZF-PEM-2 wyd. 1 z dn. 14.05.2025","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","PB-PZF-PEM-2 wyd. 1 z dn. 14.05.2025"],"lab_section":"Pracownia Zagrożeń Fizycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne pochodzące od urządzeń stosowanych w technice medycznej - diatermie chirurgiczne - diatermie fizykoterapeutyczne skanery rezonansu magnetycznego Natężenie pola magnetycznego w zakresie częstotliwości: od 0,3 MHz do 30 MHz\nZakres:\nZakres (0,012 – 16,14) A/m\nod 27 MHz do 1 GHz\nZakres (0,01 – 10,88) A/m\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB-PZF-PEM-2 wyd. 1 z dn. 14.05.2025 Srodowisko pracy - pole elektromagnetyczne pochodzace od urzadzen stosowanych w technice medycznej - diatermie chirurgiczne - diatermie fizykoterapeutyczne skanery rezonansu magnetycznego Natezenie pola magnetycznego w zakresie czestotliwosci: od 0,3 MHz do 30 MHz\nZakres:\nZakres (0,012 – 16,14) A/m\nod 27 MHz do 1 GHz\nZakres (0,01 – 10,88) A/m\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB-PZF-PEM-2 wyd. 1 z dn. 14.05.2025","categories":["environment"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,012 – 16,14) A/m"},{"name":"自 27 MHz 起","range":"do 1 GHz"},{"name":"范围","range":"(0,01 – 10,88) A/m"}],"search_zh":"工作环境 － 医疗技术设备产生的电磁场 － 外科电刀 － 理疗透热治疗仪 － 磁共振扫描仪 直接测量法 范围 自 27 MHz 起 范围 PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB-PZF-PEM-2 wyd. 1 z dn. 14.05.2025","technique_zh":"直接测量法","test_object_zh":"工作环境 － 医疗技术设备产生的电磁场 － 外科电刀 － 理疗透热治疗仪 － 磁共振扫描仪"},{"_id":"6a864bdffbf98dd0af9b1ea1","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne pochodzące od urządzeń stosowanych w technice medycznej - diatermie chirurgiczne - diatermie fizykoterapeutyczne skanery rezonansu magnetycznego","methodology":"Indukcja magnetyczna w zakresie częstotliwości: 0 Hz","parameters":[{"name":"Zakres","range":"(0,20 – 1024) mT"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Indukcja magnetyczna w zakresie częstotliwości: 0 Hz\nZakres (0,20 – 1024) mT\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB-PZF-PEM-2 wyd. 1 z dn. 14.05.2025","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","PB-PZF-PEM-2 wyd. 1 z dn. 14.05.2025"],"lab_section":"Pracownia Zagrożeń Fizycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne pochodzące od urządzeń stosowanych w technice medycznej - diatermie chirurgiczne - diatermie fizykoterapeutyczne skanery rezonansu magnetycznego Indukcja magnetyczna w zakresie częstotliwości: 0 Hz\nZakres (0,20 – 1024) mT\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB-PZF-PEM-2 wyd. 1 z dn. 14.05.2025 Srodowisko pracy - pole elektromagnetyczne pochodzace od urzadzen stosowanych w technice medycznej - diatermie chirurgiczne - diatermie fizykoterapeutyczne skanery rezonansu magnetycznego Indukcja magnetyczna w zakresie czestotliwosci: 0 Hz\nZakres (0,20 – 1024) mT\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB-PZF-PEM-2 wyd. 1 z dn. 14.05.2025","categories":["environment"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,20 – 1024) mT"}],"search_zh":"工作环境 － 医疗技术设备产生的电磁场 － 外科电刀 － 理疗透热治疗仪 － 磁共振扫描仪 直接测量法 范围 PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB-PZF-PEM-2 wyd. 1 z dn. 14.05.2025","technique_zh":"直接测量法","test_object_zh":"工作环境 － 医疗技术设备产生的电磁场 － 外科电刀 － 理疗透热治疗仪 － 磁共振扫描仪"},{"_id":"6a864bdffbf98dd0af9b1ea2","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne pochodzące od urządzeń stosowanych w technice medycznej - diatermie chirurgiczne - diatermie fizykoterapeutyczne skanery rezonansu magnetycznego","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości: 0Hz od 5 Hz","range":"do 400 kHz"},{"name":"od 800 MHz","range":"do 3 GHz"},{"name":"(z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości: 0Hz od 5 Hz do 400 kHz\nod 800 MHz do 3 GHz\n(z obliczeń)","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB-PZF-PEM-2 wyd. 1 z dn. 14.05.2025","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","PB-PZF-PEM-2 wyd. 1 z dn. 14.05.2025"],"lab_section":"Pracownia Zagrożeń Fizycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne pochodzące od urządzeń stosowanych w technice medycznej - diatermie chirurgiczne - diatermie fizykoterapeutyczne skanery rezonansu magnetycznego Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości: 0Hz od 5 Hz do 400 kHz\nod 800 MHz do 3 GHz\n(z obliczeń) PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB-PZF-PEM-2 wyd. 1 z dn. 14.05.2025 Srodowisko pracy - pole elektromagnetyczne pochodzace od urzadzen stosowanych w technice medycznej - diatermie chirurgiczne - diatermie fizykoterapeutyczne skanery rezonansu magnetycznego Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci: 0Hz od 5 Hz do 400 kHz\nod 800 MHz do 3 GHz\n(z obliczen) PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB-PZF-PEM-2 wyd. 1 z dn. 14.05.2025","categories":["environment"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"磁场强度：","parameters_zh":[{"name":"w zakresie częstotliwości: 0Hz od 5 Hz","range":"do 400 kHz"},{"name":"od 800 MHz","range":"do 3 GHz"},{"name":"（计算得出）"}],"search_zh":"工作环境 － 医疗技术设备产生的电磁场 － 外科电刀 － 理疗透热治疗仪 － 磁共振扫描仪 磁场强度： （计算得出） PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | PB-PZF-PEM-2 wyd. 1 z dn. 14.05.2025","test_object_zh":"工作环境 － 医疗技术设备产生的电磁场 － 外科电刀 － 理疗透热治疗仪 － 磁共振扫描仪"},{"_id":"6a864bdffbf98dd0af9b1ea3","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne pochodzące od systemów elektroenergetycznych i elektrycznych instalacji zasilających prądu przemiennego w energetyce","methodology":"Natężenie pola elektrycznego:","parameters":[{"name":"w zakresie częstotliwości od 45 Hz","range":"do 55 Hz"},{"name":"Zakres","range":"(0,001 – 49,9) kV/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 45 Hz do 55 Hz\nZakres (0,001 – 49,9) kV/m\nMetoda pomiarowa bezpośrednia","reference":"Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 - 150","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 - 150"],"lab_section":"Pracownia Zagrożeń Fizycznych","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego. Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (tj. Dz. U. z 2018 r. poz. 331)","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne pochodzące od systemów elektroenergetycznych i elektrycznych instalacji zasilających prądu przemiennego w energetyce Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 45 Hz do 55 Hz\nZakres (0,001 – 49,9) kV/m\nMetoda pomiarowa bezpośrednia Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 - 150 Srodowisko pracy - pole elektromagnetyczne pochodzace od systemow elektroenergetycznych i elektrycznych instalacji zasilajacych pradu przemiennego w energetyce Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 45 Hz do 55 Hz\nZakres (0,001 – 49,9) kV/m\nMetoda pomiarowa bezposrednia Podstawy i Metody Oceny Srodowiska Pracy 2016, nr 4 (90), s. 91 - 150","categories":["environment"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"电场强度：","parameters_zh":[{"name":"频率范围自 45 Hz 起","range":"do 55 Hz"},{"name":"范围","range":"(0,001 – 49,9) kV/m"}],"search_zh":"工作场所环境 — 来自电力系统与电力行业交流供电装置的电磁场 电场强度： 直接测量法 频率范围自 45 Hz 起 范围 Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 - 150","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 来自电力系统与电力行业交流供电装置的电磁场"},{"_id":"6a864bdffbf98dd0af9b1ea4","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne pochodzące od systemów elektroenergetycznych i elektrycznych instalacji zasilających prądu przemiennego w energetyce","methodology":"Natężenie pola magnetycznego w zakresie częstotliwości: od 45 Hz do 55 Hz (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego w zakresie częstotliwości: od 45 Hz do 55 Hz (z obliczeń)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 - 150","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 - 150"],"lab_section":"Pracownia Zagrożeń Fizycznych","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego. Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (tj. Dz. U. z 2018 r. poz. 331)","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne pochodzące od systemów elektroenergetycznych i elektrycznych instalacji zasilających prądu przemiennego w energetyce Natężenie pola magnetycznego w zakresie częstotliwości: od 45 Hz do 55 Hz (z obliczeń) Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 - 150 Srodowisko pracy - pole elektromagnetyczne pochodzace od systemow elektroenergetycznych i elektrycznych instalacji zasilajacych pradu przemiennego w energetyce Natezenie pola magnetycznego w zakresie czestotliwosci: od 45 Hz do 55 Hz (z obliczen) Podstawy i Metody Oceny Srodowiska Pracy 2016, nr 4 (90), s. 91 - 150","categories":["environment"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","search_zh":"工作场所环境 — 来自电力系统与电力行业交流供电装置的电磁场 Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 - 150","test_object_zh":"工作场所环境 — 来自电力系统与电力行业交流供电装置的电磁场"},{"_id":"6a864bdffbf98dd0af9b1ea5","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne pochodzące od systemów elektroenergetycznych i elektrycznych instalacji zasilających prądu przemiennego w energetyce","methodology":"Indukcja magnetyczna w zakresie częstotliwości: od 45 Hz do 55 Hz","parameters":[{"name":"Zakres","range":"0,017 μT – 19,5 mT"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Indukcja magnetyczna w zakresie częstotliwości: od 45 Hz do 55 Hz\nZakres 0,017 μT – 19,5 mT\nMetoda pomiarowa bezpośrednia","reference":"Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 - 150","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 - 150"],"lab_section":"Pracownia Zagrożeń Fizycznych","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego. Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (tj. Dz. U. z 2018 r. poz. 331)","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne pochodzące od systemów elektroenergetycznych i elektrycznych instalacji zasilających prądu przemiennego w energetyce Indukcja magnetyczna w zakresie częstotliwości: od 45 Hz do 55 Hz\nZakres 0,017 μT – 19,5 mT\nMetoda pomiarowa bezpośrednia Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 - 150 Srodowisko pracy - pole elektromagnetyczne pochodzace od systemow elektroenergetycznych i elektrycznych instalacji zasilajacych pradu przemiennego w energetyce Indukcja magnetyczna w zakresie czestotliwosci: od 45 Hz do 55 Hz\nZakres 0,017 μT – 19,5 mT\nMetoda pomiarowa bezposrednia Podstawy i Metody Oceny Srodowiska Pracy 2016, nr 4 (90), s. 91 - 150","categories":["environment"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"0,017 μT – 19,5 mT"}],"search_zh":"工作场所环境 — 来自电力系统与电力行业交流供电装置的电磁场 直接测量法 范围 Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 - 150","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 来自电力系统与电力行业交流供电装置的电磁场"},{"_id":"6a864bdffbf98dd0af9b1ea6","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń do magnetoterapii","methodology":"Natężenie pola elektrycznego:","parameters":[{"name":"w zakresie częstotliwości od 5 Hz","range":"do 1000 Hz"},{"name":"Zakres","range":"(0,001 – 49,9) kV/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 5 Hz do 1000 Hz\nZakres (0,001 – 49,9) kV/m\nMetoda pomiarowa bezpośrednia","reference":"Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180"],"lab_section":"Pracownia Zagrożeń Fizycznych","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego. Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (tj. Dz. U. z 2018 r. poz. 331)","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń do magnetoterapii Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 5 Hz do 1000 Hz\nZakres (0,001 – 49,9) kV/m\nMetoda pomiarowa bezpośrednia Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od urzadzen do magnetoterapii Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 5 Hz do 1000 Hz\nZakres (0,001 – 49,9) kV/m\nMetoda pomiarowa bezposrednia Podstawy i Metody Oceny Srodowiska Pracy 2016, nr 4 (90), s. 151 - 180","categories":["environment"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"电场强度：","parameters_zh":[{"name":"频率范围自 5 Hz 起","range":"do 1000 Hz"},{"name":"范围","range":"(0,001 – 49,9) kV/m"}],"search_zh":"工作场所环境 — 工作空间内来自磁疗设备的电磁场 电场强度： 直接测量法 频率范围自 5 Hz 起 范围 Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 工作空间内来自磁疗设备的电磁场"},{"_id":"6a864bdffbf98dd0af9b1ea7","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń do magnetoterapii","methodology":"Natężenie pola magnetycznego w zakresie częstotliwości: od 5 Hz do 1000 Hz (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego w zakresie częstotliwości: od 5 Hz do 1000 Hz (z obliczeń)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180"],"lab_section":"Pracownia Zagrożeń Fizycznych","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego. Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (tj. Dz. U. z 2018 r. poz. 331)","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń do magnetoterapii Natężenie pola magnetycznego w zakresie częstotliwości: od 5 Hz do 1000 Hz (z obliczeń) Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od urzadzen do magnetoterapii Natezenie pola magnetycznego w zakresie czestotliwosci: od 5 Hz do 1000 Hz (z obliczen) Podstawy i Metody Oceny Srodowiska Pracy 2016, nr 4 (90), s. 151 - 180","categories":["environment"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","search_zh":"工作场所环境 — 工作空间内来自磁疗设备的电磁场 Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180","test_object_zh":"工作场所环境 — 工作空间内来自磁疗设备的电磁场"},{"_id":"6a864bdffbf98dd0af9b1ea8","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń do magnetoterapii","methodology":"Indukcja magnetyczna w zakresie częstotliwości: od 5 Hz do 1000 kHz","parameters":[{"name":"Zakres","range":"0,017 μT – 19,5 mT"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Indukcja magnetyczna w zakresie częstotliwości: od 5 Hz do 1000 kHz\nZakres 0,017 μT – 19,5 mT\nMetoda pomiarowa bezpośrednia","reference":"Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180"],"lab_section":"Pracownia Zagrożeń Fizycznych","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego. Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (tj. Dz. U. z 2018 r. poz. 331)","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń do magnetoterapii Indukcja magnetyczna w zakresie częstotliwości: od 5 Hz do 1000 kHz\nZakres 0,017 μT – 19,5 mT\nMetoda pomiarowa bezpośrednia Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od urzadzen do magnetoterapii Indukcja magnetyczna w zakresie czestotliwosci: od 5 Hz do 1000 kHz\nZakres 0,017 μT – 19,5 mT\nMetoda pomiarowa bezposrednia Podstawy i Metody Oceny Srodowiska Pracy 2016, nr 4 (90), s. 151 - 180","categories":["environment"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"0,017 μT – 19,5 mT"}],"search_zh":"工作场所环境 — 工作空间内来自磁疗设备的电磁场 直接测量法 范围 Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 工作空间内来自磁疗设备的电磁场"},{"_id":"6a864bdffbf98dd0af9b1ea9","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń nadawczych systemów radiokomunikacyjnych","methodology":"Natężenie pola elektrycznego:","parameters":[{"name":"w zakresie częstotliwości od 0,1 MHz","range":"do 3 GHz"},{"name":"Zakres","range":"(0,45 – 991) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 0,1 MHz do 3 GHz\nZakres (0,45 – 991) V/m\nMetoda pomiarowa bezpośrednia","reference":"Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131"],"lab_section":"Pracownia Zagrożeń Fizycznych","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego. Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (tj. Dz. U. z 2018 r. poz. 331)","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń nadawczych systemów radiokomunikacyjnych Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 0,1 MHz do 3 GHz\nZakres (0,45 – 991) V/m\nMetoda pomiarowa bezpośrednia Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od urzadzen nadawczych systemow radiokomunikacyjnych Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 0,1 MHz do 3 GHz\nZakres (0,45 – 991) V/m\nMetoda pomiarowa bezposrednia Podstawy i Metody Oceny Srodowiska Pracy 2017, nr 2 (92), s. 89 - 131","categories":["environment"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"电场强度：","parameters_zh":[{"name":"频率范围自 0,1 MHz 起","range":"do 3 GHz"},{"name":"范围","range":"(0,45 – 991) V/m"}],"search_zh":"工作环境 － 作业空间内由无线电通信系统发射设备产生的电磁场 电场强度： 直接测量法 频率范围自 0,1 MHz 起 范围 Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131","technique_zh":"直接测量法","test_object_zh":"工作环境 － 作业空间内由无线电通信系统发射设备产生的电磁场"},{"_id":"6a864bdffbf98dd0af9b1eaa","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń nadawczych systemów radiokomunikacyjnych","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości od 0,3 MHz","range":"do 30 MHz"},{"name":"Zakres","range":"(0,01 – 15,8) A/m"},{"name":"od 20 MHz","range":"do 1 GHz"},{"name":"Zakres","range":"(0,016 – 10,5) A/m"}],"technique":"Metoda pomiarowa bezpośrednia od 100 kHz do 400 kHz (z obliczeń)","techniques":["Metoda pomiarowa bezpośrednia od 100 kHz do 400 kHz (z obliczeń)"],"computed":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 0,3 MHz do 30 MHz\nZakres (0,01 – 15,8) A/m\nod 20 MHz do 1 GHz\nZakres (0,016 – 10,5) A/m\nMetoda pomiarowa bezpośrednia od 100 kHz do 400 kHz (z obliczeń)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131"],"lab_section":"Pracownia Zagrożeń Fizycznych","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego. Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (tj. Dz. U. z 2018 r. poz. 331)","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń nadawczych systemów radiokomunikacyjnych Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 0,3 MHz do 30 MHz\nZakres (0,01 – 15,8) A/m\nod 20 MHz do 1 GHz\nZakres (0,016 – 10,5) A/m\nMetoda pomiarowa bezpośrednia od 100 kHz do 400 kHz (z obliczeń) Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od urzadzen nadawczych systemow radiokomunikacyjnych Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 0,3 MHz do 30 MHz\nZakres (0,01 – 15,8) A/m\nod 20 MHz do 1 GHz\nZakres (0,016 – 10,5) A/m\nMetoda pomiarowa bezposrednia od 100 kHz do 400 kHz (z obliczen) Podstawy i Metody Oceny Srodowiska Pracy 2017, nr 2 (92), s. 89 - 131","categories":["environment"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围自 0,3 MHz 起","range":"do 30 MHz"},{"name":"范围","range":"(0,01 – 15,8) A/m"},{"name":"od 20 MHz","range":"do 1 GHz"},{"name":"范围","range":"(0,016 – 10,5) A/m"}],"search_zh":"工作环境 － 作业空间内由无线电通信系统发射设备产生的电磁场 磁场强度： 频率范围自 0,3 MHz 起 范围 范围 Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131","test_object_zh":"工作环境 － 作业空间内由无线电通信系统发射设备产生的电磁场"},{"_id":"6a864bdffbf98dd0af9b1eab","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – nielaserowe promieniowanie optyczne","methodology":"Skuteczne natężenie napromienienia UVA, UVB i UVC w zakresie spektralnym (180 – 400) nm","parameters":[{"name":"Zakres","range":"(10-6 – 39,99) W/m2"}],"technique":"Metoda pomiarowa bezpośrednia (metoda A)","techniques":["Metoda pomiarowa bezpośrednia (metoda A)"],"computed":[],"activity":"Skuteczne natężenie napromienienia UVA, UVB i UVC w zakresie spektralnym (180 – 400) nm\nZakres (10-6 – 39,99) W/m2\nMetoda pomiarowa bezpośrednia (metoda A)","reference":"PN-EN 14255-1:2010","norm_bases":["PN-EN 14255-1:2010"],"lab_section":"Pracownia Zagrożeń Fizycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – nielaserowe promieniowanie optyczne Skuteczne natężenie napromienienia UVA, UVB i UVC w zakresie spektralnym (180 – 400) nm\nZakres (10-6 – 39,99) W/m2\nMetoda pomiarowa bezpośrednia (metoda A) PN-EN 14255-1:2010 Srodowisko pracy – nielaserowe promieniowanie optyczne Skuteczne natezenie napromienienia UVA, UVB i UVC w zakresie spektralnym (180 – 400) nm\nZakres (10-6 – 39,99) W/m2\nMetoda pomiarowa bezposrednia (metoda A) PN-EN 14255-1:2010","categories":["environment"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(10-6 – 39,99) W/m2"}],"search_zh":"工作场所环境 — 非激光光辐射 直接测量法（方法 A） 范围 PN-EN 14255-1:2010","test_object_zh":"工作场所环境 — 非激光光辐射","technique_zh":"直接测量法（方法 A）"},{"_id":"6a864bdffbf98dd0af9b1eac","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – nielaserowe promieniowanie optyczne","methodology":"Skuteczne napromienienie nadfioletem niebezpiecznym w zakresie spektralnym (180 – 400) nm ( z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Skuteczne napromienienie nadfioletem niebezpiecznym w zakresie spektralnym (180 – 400) nm ( z obliczeń)","reference":"PN-EN 14255-1:2010","norm_bases":["PN-EN 14255-1:2010"],"lab_section":"Pracownia Zagrożeń Fizycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – nielaserowe promieniowanie optyczne Skuteczne napromienienie nadfioletem niebezpiecznym w zakresie spektralnym (180 – 400) nm ( z obliczeń) PN-EN 14255-1:2010 Srodowisko pracy – nielaserowe promieniowanie optyczne Skuteczne napromienienie nadfioletem niebezpiecznym w zakresie spektralnym (180 – 400) nm ( z obliczen) PN-EN 14255-1:2010","categories":["environment"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","search_zh":"工作场所环境 — 非激光光辐射 PN-EN 14255-1:2010","test_object_zh":"工作场所环境 — 非激光光辐射"},{"_id":"6a864bdffbf98dd0af9b1ead","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – nielaserowe promieniowanie optyczne","methodology":"Natężenie napromienienia promieniowania UVA w zakresie spektralnym (315 – 400) nm","parameters":[{"name":"Zakres","range":"(10-3 – 3,999*103) W/m2"}],"technique":"Metoda pomiarowa bezpośrednia (metoda M)","techniques":["Metoda pomiarowa bezpośrednia (metoda M)"],"computed":[],"activity":"Natężenie napromienienia promieniowania UVA w zakresie spektralnym (315 – 400) nm\nZakres (10-3 – 3,999*103) W/m2\nMetoda pomiarowa bezpośrednia (metoda M)","reference":"PN-EN 14255-1:2010","norm_bases":["PN-EN 14255-1:2010"],"lab_section":"Pracownia Zagrożeń Fizycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – nielaserowe promieniowanie optyczne Natężenie napromienienia promieniowania UVA w zakresie spektralnym (315 – 400) nm\nZakres (10-3 – 3,999*103) W/m2\nMetoda pomiarowa bezpośrednia (metoda M) PN-EN 14255-1:2010 Srodowisko pracy – nielaserowe promieniowanie optyczne Natezenie napromienienia promieniowania UVA w zakresie spektralnym (315 – 400) nm\nZakres (10-3 – 3,999*103) W/m2\nMetoda pomiarowa bezposrednia (metoda M) PN-EN 14255-1:2010","categories":["environment"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(10-3 – 3,999*103) W/m2"}],"search_zh":"工作场所环境 — 非激光光辐射 直接测量法（方法 M） 范围 PN-EN 14255-1:2010","test_object_zh":"工作场所环境 — 非激光光辐射","technique_zh":"直接测量法（方法 M）"},{"_id":"6a864bdffbf98dd0af9b1eae","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – nielaserowe promieniowanie optyczne","methodology":"Napromienienie promieniowaniem UVA w zakresie spektralnym (315 – 400) nm ( z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Napromienienie promieniowaniem UVA w zakresie spektralnym (315 – 400) nm ( z obliczeń)","reference":"PN-EN 14255-1:2010","norm_bases":["PN-EN 14255-1:2010"],"lab_section":"Pracownia Zagrożeń Fizycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – nielaserowe promieniowanie optyczne Napromienienie promieniowaniem UVA w zakresie spektralnym (315 – 400) nm ( z obliczeń) PN-EN 14255-1:2010 Srodowisko pracy – nielaserowe promieniowanie optyczne Napromienienie promieniowaniem UVA w zakresie spektralnym (315 – 400) nm ( z obliczen) PN-EN 14255-1:2010","categories":["environment"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","search_zh":"工作场所环境 — 非激光光辐射 PN-EN 14255-1:2010","test_object_zh":"工作场所环境 — 非激光光辐射"},{"_id":"6a864bdffbf98dd0af9b1eaf","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – nielaserowe promieniowanie optyczne","methodology":"Skuteczne natężenie napromienienia VIS w zakresie spektralnym (300 – 700) nm","parameters":[{"name":"Zakres","range":"(10-6 – 399,9) W/m2"}],"technique":"Metoda pomiarowa bezpośrednia ( metoda O)","techniques":["Metoda pomiarowa bezpośrednia ( metoda O)"],"computed":[],"activity":"Skuteczne natężenie napromienienia VIS w zakresie spektralnym (300 – 700) nm\nZakres (10-6 – 399,9) W/m2\nMetoda pomiarowa bezpośrednia ( metoda O)","reference":"PN-EN 14255-2:2010","norm_bases":["PN-EN 14255-2:2010"],"lab_section":"Pracownia Zagrożeń Fizycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – nielaserowe promieniowanie optyczne Skuteczne natężenie napromienienia VIS w zakresie spektralnym (300 – 700) nm\nZakres (10-6 – 399,9) W/m2\nMetoda pomiarowa bezpośrednia ( metoda O) PN-EN 14255-2:2010 Srodowisko pracy – nielaserowe promieniowanie optyczne Skuteczne natezenie napromienienia VIS w zakresie spektralnym (300 – 700) nm\nZakres (10-6 – 399,9) W/m2\nMetoda pomiarowa bezposrednia ( metoda O) PN-EN 14255-2:2010","categories":["environment"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(10-6 – 399,9) W/m2"}],"search_zh":"工作场所环境 — 非激光光辐射 范围 PN-EN 14255-2:2010","test_object_zh":"工作场所环境 — 非激光光辐射"},{"_id":"6a864bdffbf98dd0af9b1eb0","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – nielaserowe promieniowanie optyczne","methodology":"Skuteczna luminancja energetyczna promieniowania VIS w zakresie spektralnym (300 – 700) nm ( z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Skuteczna luminancja energetyczna promieniowania VIS w zakresie spektralnym (300 – 700) nm ( z obliczeń)","reference":"PN-EN 14255-2:2010","norm_bases":["PN-EN 14255-2:2010"],"lab_section":"Pracownia Zagrożeń Fizycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – nielaserowe promieniowanie optyczne Skuteczna luminancja energetyczna promieniowania VIS w zakresie spektralnym (300 – 700) nm ( z obliczeń) PN-EN 14255-2:2010 Srodowisko pracy – nielaserowe promieniowanie optyczne Skuteczna luminancja energetyczna promieniowania VIS w zakresie spektralnym (300 – 700) nm ( z obliczen) PN-EN 14255-2:2010","categories":["environment"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","search_zh":"工作场所环境 — 非激光光辐射 PN-EN 14255-2:2010","test_object_zh":"工作场所环境 — 非激光光辐射"},{"_id":"6a864bdffbf98dd0af9b1eb1","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – nielaserowe promieniowanie optyczne","methodology":"Skuteczna luminancja energetyczna w zakresie spektralnym (300 – 1400) nm (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Skuteczna luminancja energetyczna w zakresie spektralnym (300 – 1400) nm (z obliczeń)","reference":"PN-EN 14255-2:2010","norm_bases":["PN-EN 14255-2:2010"],"lab_section":"Pracownia Zagrożeń Fizycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – nielaserowe promieniowanie optyczne Skuteczna luminancja energetyczna w zakresie spektralnym (300 – 1400) nm (z obliczeń) PN-EN 14255-2:2010 Srodowisko pracy – nielaserowe promieniowanie optyczne Skuteczna luminancja energetyczna w zakresie spektralnym (300 – 1400) nm (z obliczen) PN-EN 14255-2:2010","categories":["environment"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","search_zh":"工作场所环境 — 非激光光辐射 PN-EN 14255-2:2010","test_object_zh":"工作场所环境 — 非激光光辐射"},{"_id":"6a864bdffbf98dd0af9b1eb2","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – nielaserowe promieniowanie optyczne","methodology":"Natężenie napromienienia IRA i IRB w zakresie spektralnym (780 – 3000) nm","parameters":[{"name":"Zakres","range":"(100 – 3,999*103) W/m2"}],"technique":"Metoda pomiarowa bezpośrednia ( metoda R )","techniques":["Metoda pomiarowa bezpośrednia ( metoda R )"],"computed":[],"activity":"Natężenie napromienienia IRA i IRB w zakresie spektralnym (780 – 3000) nm\nZakres (100 – 3,999*103) W/m2\nMetoda pomiarowa bezpośrednia ( metoda R )","reference":"PN-EN 14255-2:2010","norm_bases":["PN-EN 14255-2:2010"],"lab_section":"Pracownia Zagrożeń Fizycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – nielaserowe promieniowanie optyczne Natężenie napromienienia IRA i IRB w zakresie spektralnym (780 – 3000) nm\nZakres (100 – 3,999*103) W/m2\nMetoda pomiarowa bezpośrednia ( metoda R ) PN-EN 14255-2:2010 Srodowisko pracy – nielaserowe promieniowanie optyczne Natezenie napromienienia IRA i IRB w zakresie spektralnym (780 – 3000) nm\nZakres (100 – 3,999*103) W/m2\nMetoda pomiarowa bezposrednia ( metoda R ) PN-EN 14255-2:2010","categories":["environment"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(100 – 3,999*103) W/m2"}],"search_zh":"工作场所环境 — 非激光光辐射 范围 PN-EN 14255-2:2010","test_object_zh":"工作场所环境 — 非激光光辐射"},{"_id":"6a864bdffbf98dd0af9b1eb3","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – nielaserowe promieniowanie optyczne","methodology":"Napromienienie IRA i IRB w zakresie spektralnym (780 – 3000) nm ( z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Napromienienie IRA i IRB w zakresie spektralnym (780 – 3000) nm ( z obliczeń)","reference":"PN-EN 14255-2:2010","norm_bases":["PN-EN 14255-2:2010"],"lab_section":"Pracownia Zagrożeń Fizycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – nielaserowe promieniowanie optyczne Napromienienie IRA i IRB w zakresie spektralnym (780 – 3000) nm ( z obliczeń) PN-EN 14255-2:2010 Srodowisko pracy – nielaserowe promieniowanie optyczne Napromienienie IRA i IRB w zakresie spektralnym (780 – 3000) nm ( z obliczen) PN-EN 14255-2:2010","categories":["environment"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","search_zh":"工作场所环境 — 非激光光辐射 PN-EN 14255-2:2010","test_object_zh":"工作场所环境 — 非激光光辐射"},{"_id":"6a864bdffbf98dd0af9b1eb4","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – nielaserowe promieniowanie optyczne","methodology":"Skuteczne natężenie napromienienia IRA w zakresie spektralnym (780 – 1400) nm","parameters":[{"name":"Zakres","range":"(10-3 – 3,999*103) W/m2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne natężenie napromienienia IRA w zakresie spektralnym (780 – 1400) nm\nZakres (10-3 – 3,999*103) W/m2\nMetoda pomiarowa bezpośrednia","reference":"PN-T-05687: 2002 p.2.5.4","norm_bases":["PN-T-05687: 2002 p.2.5.4"],"lab_section":"Pracownia Zagrożeń Fizycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – nielaserowe promieniowanie optyczne Skuteczne natężenie napromienienia IRA w zakresie spektralnym (780 – 1400) nm\nZakres (10-3 – 3,999*103) W/m2\nMetoda pomiarowa bezpośrednia PN-T-05687: 2002 p.2.5.4 Srodowisko pracy – nielaserowe promieniowanie optyczne Skuteczne natezenie napromienienia IRA w zakresie spektralnym (780 – 1400) nm\nZakres (10-3 – 3,999*103) W/m2\nMetoda pomiarowa bezposrednia PN-T-05687: 2002 p.2.5.4","categories":["environment"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(10-3 – 3,999*103) W/m2"}],"search_zh":"工作场所环境 — 非激光光辐射 直接测量法 范围 PN-T-05687: 2002 p.2.5.4","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 非激光光辐射"},{"_id":"6a864bdffbf98dd0af9b1eb5","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – nielaserowe promieniowanie optyczne","methodology":"Skuteczna luminancja energetyczna, IRA w zakresie spektralnym (780 – 1400) nm (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Skuteczna luminancja energetyczna, IRA w zakresie spektralnym (780 – 1400) nm (z obliczeń)","reference":"PN-T-05687: 2002 p.2.5.4","norm_bases":["PN-T-05687: 2002 p.2.5.4"],"lab_section":"Pracownia Zagrożeń Fizycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – nielaserowe promieniowanie optyczne Skuteczna luminancja energetyczna, IRA w zakresie spektralnym (780 – 1400) nm (z obliczeń) PN-T-05687: 2002 p.2.5.4 Srodowisko pracy – nielaserowe promieniowanie optyczne Skuteczna luminancja energetyczna, IRA w zakresie spektralnym (780 – 1400) nm (z obliczen) PN-T-05687: 2002 p.2.5.4","categories":["environment"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","search_zh":"工作场所环境 — 非激光光辐射 PN-T-05687: 2002 p.2.5.4","test_object_zh":"工作场所环境 — 非激光光辐射"},{"_id":"6a864bdffbf98dd0af9b1eb6","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – nielaserowe promieniowanie optyczne","methodology":"Natężenie napromienienia VIS, IRA, IRB w zakresie spektralnym (380 – 3000) nm","parameters":[{"name":"Zakres","range":"(100 – 3999*103) W/m2"}],"technique":"Metoda pomiarowa bezpośrednia (metoda X)","techniques":["Metoda pomiarowa bezpośrednia (metoda X)"],"computed":[],"activity":"Natężenie napromienienia VIS, IRA, IRB w zakresie spektralnym (380 – 3000) nm\nZakres (100 – 3999*103) W/m2\nMetoda pomiarowa bezpośrednia (metoda X)","reference":"PN-EN 14255-2:2010","norm_bases":["PN-EN 14255-2:2010"],"lab_section":"Pracownia Zagrożeń Fizycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – nielaserowe promieniowanie optyczne Natężenie napromienienia VIS, IRA, IRB w zakresie spektralnym (380 – 3000) nm\nZakres (100 – 3999*103) W/m2\nMetoda pomiarowa bezpośrednia (metoda X) PN-EN 14255-2:2010 Srodowisko pracy – nielaserowe promieniowanie optyczne Natezenie napromienienia VIS, IRA, IRB w zakresie spektralnym (380 – 3000) nm\nZakres (100 – 3999*103) W/m2\nMetoda pomiarowa bezposrednia (metoda X) PN-EN 14255-2:2010","categories":["environment"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(100 – 3999*103) W/m2"}],"search_zh":"工作场所环境 — 非激光光辐射 直接测量法（方法 X） 范围 PN-EN 14255-2:2010","test_object_zh":"工作场所环境 — 非激光光辐射","technique_zh":"直接测量法（方法 X）"},{"_id":"6a864bdffbf98dd0af9b1eb7","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – nielaserowe promieniowanie optyczne","methodology":"Napromienienie VIS, IRA i IRB w zakresie spektralnym (380 – 3000) nm (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Napromienienie VIS, IRA i IRB w zakresie spektralnym (380 – 3000) nm (z obliczeń)","reference":"PN-EN 14255-2:2010","norm_bases":["PN-EN 14255-2:2010"],"lab_section":"Pracownia Zagrożeń Fizycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – nielaserowe promieniowanie optyczne Napromienienie VIS, IRA i IRB w zakresie spektralnym (380 – 3000) nm (z obliczeń) PN-EN 14255-2:2010 Srodowisko pracy – nielaserowe promieniowanie optyczne Napromienienie VIS, IRA i IRB w zakresie spektralnym (380 – 3000) nm (z obliczen) PN-EN 14255-2:2010","categories":["environment"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","search_zh":"工作场所环境 — 非激光光辐射 PN-EN 14255-2:2010","test_object_zh":"工作场所环境 — 非激光光辐射"},{"_id":"6a864bdffbf98dd0af9b1eb8","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat zimny","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(-30 – 10) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(-30 – 20) °C"},{"name":"Wilgotność powietrza"},{"name":"Zakres","range":"(20 – 90) %"},{"name":"Prędkość powietrza"},{"name":"Zakres","range":"(0,15 – 5,0) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (-30 – 10) °C\nTemperatura poczernionej kuli\nZakres (-30 – 20) °C\nWilgotność powietrza\nZakres (20 – 90) %\nPrędkość powietrza\nZakres (0,15 – 5,0) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 11079:2008+Ap:2013-10","norm_bases":["PN-EN ISO 11079:2008+Ap:2013-10"],"lab_section":"Pracownia Zagrożeń Fizycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – mikroklimat zimny Temperatura powietrza\nZakres:\nZakres (-30 – 10) °C\nTemperatura poczernionej kuli\nZakres (-30 – 20) °C\nWilgotność powietrza\nZakres (20 – 90) %\nPrędkość powietrza\nZakres (0,15 – 5,0) m/s\nMetoda pomiarowa bezpośrednia PN-EN ISO 11079:2008+Ap:2013-10 Srodowisko pracy – mikroklimat zimny Temperatura powietrza\nZakres:\nZakres (-30 – 10) °C\nTemperatura poczernionej kuli\nZakres (-30 – 20) °C\nWilgotnosc powietrza\nZakres (20 – 90) %\nPredkosc powietrza\nZakres (0,15 – 5,0) m/s\nMetoda pomiarowa bezposrednia PN-EN ISO 11079:2008+Ap:2013-10","categories":["environment"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(-30 – 10) °C"},{"name":"黑球温度"},{"name":"范围","range":"(-30 – 20) °C"},{"name":"空气湿度"},{"name":"范围","range":"(20 – 90) %"},{"name":"空气流速"},{"name":"范围","range":"(0,15 – 5,0) m/s"}],"search_zh":"工作场所环境 — 低温微气候 空气温度 直接测量法 范围 黑球温度 范围 空气湿度 范围 空气流速 范围 PN-EN ISO 11079:2008+Ap:2013-10","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 低温微气候"},{"_id":"6a864bdffbf98dd0af9b1eb9","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat zimny","methodology":"Wskaźnik twc, Wskaźnik IREQmin, Wskaźnik IREQneutral, Dopuszczalny czas ekspozycji Dlim (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik twc, Wskaźnik IREQmin, Wskaźnik IREQneutral, Dopuszczalny czas ekspozycji Dlim (z obliczeń)","reference":"PN-EN ISO 11079:2008+Ap:2013-10","norm_bases":["PN-EN ISO 11079:2008+Ap:2013-10"],"lab_section":"Pracownia Zagrożeń Fizycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – mikroklimat zimny Wskaźnik twc, Wskaźnik IREQmin, Wskaźnik IREQneutral, Dopuszczalny czas ekspozycji Dlim (z obliczeń) PN-EN ISO 11079:2008+Ap:2013-10 Srodowisko pracy – mikroklimat zimny Wskaznik twc, Wskaznik IREQmin, Wskaznik IREQneutral, Dopuszczalny czas ekspozycji Dlim (z obliczen) PN-EN ISO 11079:2008+Ap:2013-10","categories":["environment"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","search_zh":"工作场所环境 — 低温微气候 PN-EN ISO 11079:2008+Ap:2013-10","test_object_zh":"工作场所环境 — 低温微气候"},{"_id":"6a864bdffbf98dd0af9b1eba","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat umiarkowany","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(10 – 30) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(10 – 60) °C"},{"name":"Wilgotność powietrza"},{"name":"Zakres","range":"(20 – 90) %"},{"name":"Prędkość powietrza"},{"name":"Zakres","range":"(0,15 – 1,0) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (10 – 30) °C\nTemperatura poczernionej kuli\nZakres (10 – 60) °C\nWilgotność powietrza\nZakres (20 – 90) %\nPrędkość powietrza\nZakres (0,15 – 1,0) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7730:2006+Ap2:2016-04","norm_bases":["PN-EN ISO 7730:2006+Ap2:2016-04"],"lab_section":"Pracownia Zagrożeń Fizycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – mikroklimat umiarkowany Temperatura powietrza\nZakres:\nZakres (10 – 30) °C\nTemperatura poczernionej kuli\nZakres (10 – 60) °C\nWilgotność powietrza\nZakres (20 – 90) %\nPrędkość powietrza\nZakres (0,15 – 1,0) m/s\nMetoda pomiarowa bezpośrednia PN-EN ISO 7730:2006+Ap2:2016-04 Srodowisko pracy – mikroklimat umiarkowany Temperatura powietrza\nZakres:\nZakres (10 – 30) °C\nTemperatura poczernionej kuli\nZakres (10 – 60) °C\nWilgotnosc powietrza\nZakres (20 – 90) %\nPredkosc powietrza\nZakres (0,15 – 1,0) m/s\nMetoda pomiarowa bezposrednia PN-EN ISO 7730:2006+Ap2:2016-04","categories":["environment"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(10 – 30) °C"},{"name":"黑球温度"},{"name":"范围","range":"(10 – 60) °C"},{"name":"空气湿度"},{"name":"范围","range":"(20 – 90) %"},{"name":"空气流速"},{"name":"范围","range":"(0,15 – 1,0) m/s"}],"search_zh":"工作场所环境 — 中等微气候 空气温度 直接测量法 范围 黑球温度 范围 空气湿度 范围 空气流速 范围 PN-EN ISO 7730:2006+Ap2:2016-04","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 中等微气候"},{"_id":"6a864bdffbf98dd0af9b1ebb","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat umiarkowany","methodology":"Wskaźnik PMV, Wskaźnik PPD (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik PMV, Wskaźnik PPD (z obliczeń)","reference":"PN-EN ISO 7730:2006+Ap2:2016-04","norm_bases":["PN-EN ISO 7730:2006+Ap2:2016-04"],"lab_section":"Pracownia Zagrożeń Fizycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – mikroklimat umiarkowany Wskaźnik PMV, Wskaźnik PPD (z obliczeń) PN-EN ISO 7730:2006+Ap2:2016-04 Srodowisko pracy – mikroklimat umiarkowany Wskaznik PMV, Wskaznik PPD (z obliczen) PN-EN ISO 7730:2006+Ap2:2016-04","categories":["environment"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"PMV 指数、PPD 指数（计算值）","search_zh":"工作场所环境 — 中等微气候 PMV 指数、PPD 指数（计算值） PN-EN ISO 7730:2006+Ap2:2016-04","test_object_zh":"工作场所环境 — 中等微气候"},{"_id":"6a864bdffbf98dd0af9b1ebc","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat gorący","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(15 – 60) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(15 – 60) °C"},{"name":"Temperatura wilgotna naturalna"},{"name":"Zakres","range":"(15 – 60) °C"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (15 – 60) °C\nTemperatura poczernionej kuli\nZakres (15 – 60) °C\nTemperatura wilgotna naturalna\nZakres (15 – 60) °C\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7243:2018-01","norm_bases":["PN-EN ISO 7243:2018-01"],"lab_section":"Pracownia Zagrożeń Fizycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – mikroklimat gorący Temperatura powietrza\nZakres:\nZakres (15 – 60) °C\nTemperatura poczernionej kuli\nZakres (15 – 60) °C\nTemperatura wilgotna naturalna\nZakres (15 – 60) °C\nMetoda pomiarowa bezpośrednia PN-EN ISO 7243:2018-01 Srodowisko pracy – mikroklimat goracy Temperatura powietrza\nZakres:\nZakres (15 – 60) °C\nTemperatura poczernionej kuli\nZakres (15 – 60) °C\nTemperatura wilgotna naturalna\nZakres (15 – 60) °C\nMetoda pomiarowa bezposrednia PN-EN ISO 7243:2018-01","categories":["environment"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(15 – 60) °C"},{"name":"黑球温度"},{"name":"范围","range":"(15 – 60) °C"},{"name":"自然湿球温度"},{"name":"范围","range":"(15 – 60) °C"}],"search_zh":"工作场所环境 — 高温微气候 空气温度 直接测量法 范围 黑球温度 范围 自然湿球温度 范围 PN-EN ISO 7243:2018-01","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 高温微气候"},{"_id":"6a864bdffbf98dd0af9b1ebd","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat gorący","methodology":"Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń)","reference":"PN-EN ISO 7243:2018-01","norm_bases":["PN-EN ISO 7243:2018-01"],"lab_section":"Pracownia Zagrożeń Fizycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – mikroklimat gorący Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń) PN-EN ISO 7243:2018-01 Srodowisko pracy – mikroklimat goracy Wskaznik WBGT, Wskaznik WBGTeff (z obliczen) PN-EN ISO 7243:2018-01","categories":["environment"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"WBGT 指数、WBGTeff 指数（计算值）","search_zh":"工作场所环境 — 高温微气候 WBGT 指数、WBGTeff 指数（计算值） PN-EN ISO 7243:2018-01","test_object_zh":"工作场所环境 — 高温微气候"},{"_id":"6a864bdffbf98dd0af9b1ebe","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie tlenków żelaza – w przeliczeniu na Fe Tlenek żelaza (III) Tlenek żelaza (II)","parameters":[{"name":"Tetratlenek triżelaza – frakcja wdychalna"},{"name":"Zakres","range":"(0,035 – 10,42) mg/m3"},{"name":"– frakcja respirabilna"},{"name":"Zakres","range":"(0,018 – 5,48) mg/m3"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie tlenków żelaza – w przeliczeniu na Fe Tlenek żelaza (III) Tlenek żelaza (II)\nZakres:\nTetratlenek triżelaza – frakcja wdychalna\nZakres (0,035 – 10,42) mg/m3\n– frakcja respirabilna\nZakres (0,018 – 5,48) mg/m3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04469:2025-02","norm_bases":["PN-Z-04469:2025-02"],"lab_section":"Pracownia Zagrożeń Chemicznych i Pyłowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie tlenków żelaza – w przeliczeniu na Fe Tlenek żelaza (III) Tlenek żelaza (II)\nZakres:\nTetratlenek triżelaza – frakcja wdychalna\nZakres (0,035 – 10,42) mg/m3\n– frakcja respirabilna\nZakres (0,018 – 5,48) mg/m3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04469:2025-02 Srodowisko pracy – powietrze Stezenie tlenkow zelaza – w przeliczeniu na Fe Tlenek zelaza (III) Tlenek zelaza (II)\nZakres:\nTetratlenek trizelaza – frakcja wdychalna\nZakres (0,035 – 10,42) mg/m3\n– frakcja respirabilna\nZakres (0,018 – 5,48) mg/m3\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04469:2025-02","categories":["environment"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"Tetratlenek triżelaza – frakcja wdychalna"},{"name":"范围","range":"(0,035 – 10,42) mg/m3"},{"name":"— 呼吸性组分"},{"name":"范围","range":"(0,018 – 5,48) mg/m3"}],"search_zh":"工作场所环境 — 空气 火焰原子吸收光谱法（FAAS） 范围 — 呼吸性组分 范围 PN-Z-04469:2025-02","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a864bdffbf98dd0af9b1ebf","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie manganu i jego związków nieorganicznych w przeliczeniu na Mn – frakcja wdychalna","parameters":[{"name":"Zakres","range":"(0,0056 – 1,11) mg/m3"},{"name":"– frakcja respirabilna"},{"name":"Zakres","range":"(0,0015 – 1,17) mg/m3"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie manganu i jego związków nieorganicznych w przeliczeniu na Mn – frakcja wdychalna\nZakres:\nZakres (0,0056 – 1,11) mg/m3\n– frakcja respirabilna\nZakres (0,0015 – 1,17) mg/m3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04472:2015-10/Ap1:2015-12","norm_bases":["PN-Z-04472:2015-10/Ap1:2015-12"],"lab_section":"Pracownia Zagrożeń Chemicznych i Pyłowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie manganu i jego związków nieorganicznych w przeliczeniu na Mn – frakcja wdychalna\nZakres:\nZakres (0,0056 – 1,11) mg/m3\n– frakcja respirabilna\nZakres (0,0015 – 1,17) mg/m3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04472:2015-10/Ap1:2015-12 Srodowisko pracy – powietrze Stezenie manganu i jego zwiazkow nieorganicznych w przeliczeniu na Mn – frakcja wdychalna\nZakres:\nZakres (0,0056 – 1,11) mg/m3\n– frakcja respirabilna\nZakres (0,0015 – 1,17) mg/m3\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04472:2015-10/Ap1:2015-12","categories":["environment"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,0056 – 1,11) mg/m3"},{"name":"— 呼吸性组分"},{"name":"范围","range":"(0,0015 – 1,17) mg/m3"}],"search_zh":"工作场所环境 — 空气 锰及其无机化合物浓度（以 Mn 计）－ 可吸入性粉尘 火焰原子吸收光谱法（FAAS） 范围 — 呼吸性组分 范围 PN-Z-04472:2015-10/Ap1:2015-12","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 — 空气","methodology_zh":"锰及其无机化合物浓度（以 Mn 计）－ 可吸入性粉尘"},{"_id":"6a864bdffbf98dd0af9b1ec0","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie tlenku cynku w przeliczeniu na Zn – frakcja wdychalna","parameters":[{"name":"Zakres","range":"(0,03 – 20,0) mg/m3"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie tlenku cynku w przeliczeniu na Zn – frakcja wdychalna\nZakres (0,03 – 20,0) mg/m3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-87/Z-04100.03","norm_bases":["PN-87/Z-04100.03"],"lab_section":"Pracownia Zagrożeń Chemicznych i Pyłowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie tlenku cynku w przeliczeniu na Zn – frakcja wdychalna\nZakres (0,03 – 20,0) mg/m3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-87/Z-04100.03 Srodowisko pracy – powietrze Stezenie tlenku cynku w przeliczeniu na Zn – frakcja wdychalna\nZakres (0,03 – 20,0) mg/m3\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-87/Z-04100.03","categories":["environment"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,03 – 20,0) mg/m3"}],"search_zh":"工作场所环境 — 空气 火焰原子吸收光谱法（FAAS） 范围 PN-87/Z-04100.03","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a864bdffbf98dd0af9b1ec1","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie ołowiu i jego związków nieorganicznych w przeliczeniu na Pb – frakcja wdychalna","parameters":[{"name":"Zakres","range":"(0,0035 – 0,14) mg/m3"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie ołowiu i jego związków nieorganicznych w przeliczeniu na Pb – frakcja wdychalna\nZakres (0,0035 – 0,14) mg/m3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04487:2017-10","norm_bases":["PN-Z-04487:2017-10"],"lab_section":"Pracownia Zagrożeń Chemicznych i Pyłowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie ołowiu i jego związków nieorganicznych w przeliczeniu na Pb – frakcja wdychalna\nZakres (0,0035 – 0,14) mg/m3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04487:2017-10 Srodowisko pracy – powietrze Stezenie olowiu i jego zwiazkow nieorganicznych w przeliczeniu na Pb – frakcja wdychalna\nZakres (0,0035 – 0,14) mg/m3\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04487:2017-10","categories":["environment"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,0035 – 0,14) mg/m3"}],"search_zh":"工作场所环境 — 空气 火焰原子吸收光谱法（FAAS） 范围 PN-Z-04487:2017-10","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a864bdffbf98dd0af9b1ec2","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie miedzi i jej związków nieorganicznych w przeliczeniu na Cu","parameters":[{"name":"Zakres","range":"(0,003 – 4,0) mg/m3"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie miedzi i jej związków nieorganicznych w przeliczeniu na Cu\nZakres (0,003 – 4,0) mg/m3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04106-3:2002 z wyłączeniem punktu 9.1 i 10.1","norm_bases":["PN-Z-04106-3:2002 z wyłączeniem punktu 9.1 i 10.1"],"lab_section":"Pracownia Zagrożeń Chemicznych i Pyłowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie miedzi i jej związków nieorganicznych w przeliczeniu na Cu\nZakres (0,003 – 4,0) mg/m3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04106-3:2002 z wyłączeniem punktu 9.1 i 10.1 Srodowisko pracy – powietrze Stezenie miedzi i jej zwiazkow nieorganicznych w przeliczeniu na Cu\nZakres (0,003 – 4,0) mg/m3\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04106-3:2002 z wylaczeniem punktu 9.1 i 10.1","categories":["environment"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,003 – 4,0) mg/m3"}],"search_zh":"工作场所环境 — 空气 铜及其无机化合物浓度（以 Cu 计） 火焰原子吸收光谱法（FAAS） 范围 PN-Z-04106-3:2002 z wyłączeniem punktu 9.1 i 10.1","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 — 空气","methodology_zh":"铜及其无机化合物浓度（以 Cu 计）"},{"_id":"6a864bdffbf98dd0af9b1ec3","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie wodorotlenku potasu","parameters":[{"name":"Zakres","range":"(0,014 – 3,45) mg/m3"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie wodorotlenku potasu\nZakres (0,014 – 3,45) mg/m3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04436:2011","norm_bases":["PN-Z-04436:2011"],"lab_section":"Pracownia Zagrożeń Chemicznych i Pyłowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie wodorotlenku potasu\nZakres (0,014 – 3,45) mg/m3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04436:2011 Srodowisko pracy – powietrze Stezenie wodorotlenku potasu\nZakres (0,014 – 3,45) mg/m3\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04436:2011","categories":["environment"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,014 – 3,45) mg/m3"}],"search_zh":"工作场所环境 — 空气 氢氧化钾浓度 火焰原子吸收光谱法（FAAS） 范围 PN-Z-04436:2011","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 — 空气","methodology_zh":"氢氧化钾浓度"},{"_id":"6a864bdffbf98dd0af9b1ec4","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie wodorotlenku sodu","parameters":[{"name":"Zakres","range":"(0,0069 – 3,45) mg/m3"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie wodorotlenku sodu\nZakres (0,0069 – 3,45) mg/m3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04435:2011","norm_bases":["PN-Z-04435:2011"],"lab_section":"Pracownia Zagrożeń Chemicznych i Pyłowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie wodorotlenku sodu\nZakres (0,0069 – 3,45) mg/m3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04435:2011 Srodowisko pracy – powietrze Stezenie wodorotlenku sodu\nZakres (0,0069 – 3,45) mg/m3\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04435:2011","categories":["environment"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,0069 – 3,45) mg/m3"}],"search_zh":"工作场所环境 — 空气 氢氧化钠浓度 火焰原子吸收光谱法（FAAS） 范围 PN-Z-04435:2011","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 — 空气","methodology_zh":"氢氧化钠浓度"},{"_id":"6a864bdffbf98dd0af9b1ec5","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie cyny i jej związków nieorganicznych z wyjątkiem stannanu w przeliczeniu na Sn – frakcja wdychalna","parameters":[{"name":"Zakres","range":"(0,174 – 10,42) mg/m3"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie cyny i jej związków nieorganicznych z wyjątkiem stannanu w przeliczeniu na Sn – frakcja wdychalna\nZakres (0,174 – 10,42) mg/m3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04488:2017-10","norm_bases":["PN-Z-04488:2017-10"],"lab_section":"Pracownia Zagrożeń Chemicznych i Pyłowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie cyny i jej związków nieorganicznych z wyjątkiem stannanu w przeliczeniu na Sn – frakcja wdychalna\nZakres (0,174 – 10,42) mg/m3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04488:2017-10 Srodowisko pracy – powietrze Stezenie cyny i jej zwiazkow nieorganicznych z wyjatkiem stannanu w przeliczeniu na Sn – frakcja wdychalna\nZakres (0,174 – 10,42) mg/m3\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04488:2017-10","categories":["environment"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,174 – 10,42) mg/m3"}],"search_zh":"工作场所环境 — 空气 火焰原子吸收光谱法（FAAS） 范围 PN-Z-04488:2017-10","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a864bdffbf98dd0af9b1ec6","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie chromu metalicznego, związków chromu: chrom (II), chrom (III), chrom (VI) – w przeliczeniu na Cr","parameters":[{"name":"Zakres","range":"(0,0174 – 2,78) mg/m3"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie chromu metalicznego, związków chromu: chrom (II), chrom (III), chrom (VI) – w przeliczeniu na Cr\nZakres (0,0174 – 2,78) mg/m3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04434:2011","norm_bases":["PN-Z-04434:2011"],"lab_section":"Pracownia Zagrożeń Chemicznych i Pyłowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie chromu metalicznego, związków chromu: chrom (II), chrom (III), chrom (VI) – w przeliczeniu na Cr\nZakres (0,0174 – 2,78) mg/m3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04434:2011 Srodowisko pracy – powietrze Stezenie chromu metalicznego, zwiazkow chromu: chrom (II), chrom (III), chrom (VI) – w przeliczeniu na Cr\nZakres (0,0174 – 2,78) mg/m3\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04434:2011","categories":["materials","environment"],"row_index":55,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,0174 – 2,78) mg/m3"}],"search_zh":"工作场所环境 — 空气 火焰原子吸收光谱法（FAAS） 范围 PN-Z-04434:2011","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a864bdffbf98dd0af9b1ec7","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie chromu metalicznego, związków chromu (II) – w przeliczeniu na Cr (II), związków chromu (III) – w przeliczeniu na Cr (III)","parameters":[],"technique":"Metoda z obliczeń","techniques":["Metoda z obliczeń"],"computed":[],"activity":"Stężenie chromu metalicznego, związków chromu (II) – w przeliczeniu na Cr (II), związków chromu (III) – w przeliczeniu na Cr (III)\nMetoda z obliczeń","reference":"Instrukcja do normy | PN-Z-04434:2011 Wyd. 1 z dnia 25.05.2022 r.","norm_bases":["Instrukcja do normy","PN-Z-04434:2011 Wyd. 1 z dnia 25.05.2022 r."],"lab_section":"Pracownia Zagrożeń Chemicznych i Pyłowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie chromu metalicznego, związków chromu (II) – w przeliczeniu na Cr (II), związków chromu (III) – w przeliczeniu na Cr (III)\nMetoda z obliczeń Instrukcja do normy | PN-Z-04434:2011 Wyd. 1 z dnia 25.05.2022 r. Srodowisko pracy – powietrze Stezenie chromu metalicznego, zwiazkow chromu (II) – w przeliczeniu na Cr (II), zwiazkow chromu (III) – w przeliczeniu na Cr (III)\nMetoda z obliczen Instrukcja do normy | PN-Z-04434:2011 Wyd. 1 z dnia 25.05.2022 r.","categories":["materials","environment"],"row_index":56,"parse_version":4,"parse_source":"agent-claude-code","search_zh":"工作场所环境 — 空气 计算法 Instrukcja do normy | PN-Z-04434:2011 Wyd. 1 z dnia 25.05.2022 r.","technique_zh":"计算法","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a864bdffbf98dd0af9b1ec8","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie kadmu i jego związków nieorganicznych w przeliczeniu na Cd","parameters":[{"name":"frakcja wdychalna"},{"name":"Zakres","range":"(0,00006 – 0,021) mg/m3"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie kadmu i jego związków nieorganicznych w przeliczeniu na Cd\nZakres:\nfrakcja wdychalna\nZakres (0,00006 – 0,021) mg/m3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04102-3:2013-10","norm_bases":["PN-Z-04102-3:2013-10"],"lab_section":"Pracownia Zagrożeń Chemicznych i Pyłowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie kadmu i jego związków nieorganicznych w przeliczeniu na Cd\nZakres:\nfrakcja wdychalna\nZakres (0,00006 – 0,021) mg/m3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04102-3:2013-10 Srodowisko pracy – powietrze Stezenie kadmu i jego zwiazkow nieorganicznych w przeliczeniu na Cd\nZakres:\nfrakcja wdychalna\nZakres (0,00006 – 0,021) mg/m3\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04102-3:2013-10","categories":["environment"],"row_index":57,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"可吸入组分"},{"name":"范围","range":"(0,00006 – 0,021) mg/m3"}],"search_zh":"工作场所环境 — 空气 火焰原子吸收光谱法（FAAS） 可吸入组分 范围 PN-Z-04102-3:2013-10","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a864bdffbf98dd0af9b1ec9","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie związków niklu w przeliczeniu na Ni","parameters":[{"name":"frakcja wdychalna"},{"name":"Zakres","range":"(0,0007 – 0,1042) mg/m3"},{"name":"frakcja respirabilna"},{"name":"Zakres","range":"(0,0007 – 0,1100) mg/m3"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie związków niklu w przeliczeniu na Ni\nZakres:\nfrakcja wdychalna\nZakres (0,0007 – 0,1042) mg/m3\nfrakcja respirabilna\nZakres (0,0007 – 0,1100) mg/m3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04502:2019-10","norm_bases":["PN-Z-04502:2019-10"],"lab_section":"Pracownia Zagrożeń Chemicznych i Pyłowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie związków niklu w przeliczeniu na Ni\nZakres:\nfrakcja wdychalna\nZakres (0,0007 – 0,1042) mg/m3\nfrakcja respirabilna\nZakres (0,0007 – 0,1100) mg/m3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04502:2019-10 Srodowisko pracy – powietrze Stezenie zwiazkow niklu w przeliczeniu na Ni\nZakres:\nfrakcja wdychalna\nZakres (0,0007 – 0,1042) mg/m3\nfrakcja respirabilna\nZakres (0,0007 – 0,1100) mg/m3\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04502:2019-10","categories":["environment"],"row_index":58,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"可吸入组分"},{"name":"范围","range":"(0,0007 – 0,1042) mg/m3"},{"name":"呼吸性组分"},{"name":"范围","range":"(0,0007 – 0,1100) mg/m3"}],"search_zh":"工作场所环境 — 空气 镍化合物浓度（以 Ni 计） 火焰原子吸收光谱法（FAAS） 可吸入组分 范围 呼吸性组分 范围 PN-Z-04502:2019-10","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 — 空气","methodology_zh":"镍化合物浓度（以 Ni 计）"},{"_id":"6a864bdffbf98dd0af9b1eca","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie niklu metalicznego","parameters":[{"name":"Zakres","range":"(0,021 – 1,04) mg/m3"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie niklu metalicznego\nZakres (0,021 – 1,04) mg/m3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04502:2019-10","norm_bases":["PN-Z-04502:2019-10"],"lab_section":"Pracownia Zagrożeń Chemicznych i Pyłowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie niklu metalicznego\nZakres (0,021 – 1,04) mg/m3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04502:2019-10 Srodowisko pracy – powietrze Stezenie niklu metalicznego\nZakres (0,021 – 1,04) mg/m3\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04502:2019-10","categories":["materials","environment"],"row_index":59,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,021 – 1,04) mg/m3"}],"search_zh":"工作场所环境 — 空气 金属镍浓度 火焰原子吸收光谱法（FAAS） 范围 PN-Z-04502:2019-10","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 — 空气","methodology_zh":"金属镍浓度"},{"_id":"6a864bdffbf98dd0af9b1ecb","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie kobaltu i jego związków nieorganicznych w przeliczeniu na Co","parameters":[{"name":"Zakres","range":"(0,0069 – 0,069) mg/m3"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie kobaltu i jego związków nieorganicznych w przeliczeniu na Co\nZakres (0,0069 – 0,069) mg/m3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04291:2003","norm_bases":["PN-Z-04291:2003"],"lab_section":"Pracownia Zagrożeń Chemicznych i Pyłowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie kobaltu i jego związków nieorganicznych w przeliczeniu na Co\nZakres (0,0069 – 0,069) mg/m3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04291:2003 Srodowisko pracy – powietrze Stezenie kobaltu i jego zwiazkow nieorganicznych w przeliczeniu na Co\nZakres (0,0069 – 0,069) mg/m3\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04291:2003","categories":["environment"],"row_index":60,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,0069 – 0,069) mg/m3"}],"search_zh":"工作场所环境 — 空气 火焰原子吸收光谱法（FAAS） 范围 PN-Z-04291:2003","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a864bdffbf98dd0af9b1ecc","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie amoniaku","parameters":[{"name":"Zakres","range":"(1,12 – 37,5) mg/m3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie amoniaku\nZakres (1,12 – 37,5) mg/m3\nMetoda spektrofotometryczna","reference":"PN-Z-04041:1971","norm_bases":["PN-Z-04041:1971"],"lab_section":"Pracownia Zagrożeń Chemicznych i Pyłowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie amoniaku\nZakres (1,12 – 37,5) mg/m3\nMetoda spektrofotometryczna PN-Z-04041:1971 Srodowisko pracy – powietrze Stezenie amoniaku\nZakres (1,12 – 37,5) mg/m3\nMetoda spektrofotometryczna PN-Z-04041:1971","categories":["environment"],"row_index":61,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(1,12 – 37,5) mg/m3"}],"search_zh":"工作场所环境 — 空气 氨浓度 分光光度法 范围 PN-Z-04041:1971","technique_zh":"分光光度法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"氨浓度"},{"_id":"6a864bdffbf98dd0af9b1ecd","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie formaldehydu","parameters":[{"name":"Zakres","range":"(0,04 – 6,4) mg/m3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie formaldehydu\nZakres (0,04 – 6,4) mg/m3\nMetoda spektrofotometryczna","reference":"PN-Z-04045-04:1976","norm_bases":["PN-Z-04045-04:1976"],"lab_section":"Pracownia Zagrożeń Chemicznych i Pyłowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie formaldehydu\nZakres (0,04 – 6,4) mg/m3\nMetoda spektrofotometryczna PN-Z-04045-04:1976 Srodowisko pracy – powietrze Stezenie formaldehydu\nZakres (0,04 – 6,4) mg/m3\nMetoda spektrofotometryczna PN-Z-04045-04:1976","categories":["environment"],"row_index":62,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,04 – 6,4) mg/m3"}],"search_zh":"工作场所环境 — 空气 甲醛浓度 分光光度法 范围 PN-Z-04045-04:1976","technique_zh":"分光光度法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"甲醛浓度"},{"_id":"6a864bdffbf98dd0af9b1ece","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie chlorowodoru","parameters":[{"name":"Zakres","range":"(0,5 – 10) mg/m3"}],"technique":"Metoda turbidymetryczna","techniques":["Metoda turbidymetryczna"],"computed":[],"activity":"Stężenie chlorowodoru\nZakres (0,5 – 10) mg/m3\nMetoda turbidymetryczna","reference":"PN-Z-04450:2014-08","norm_bases":["PN-Z-04450:2014-08"],"lab_section":"Pracownia Zagrożeń Chemicznych i Pyłowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie chlorowodoru\nZakres (0,5 – 10) mg/m3\nMetoda turbidymetryczna PN-Z-04450:2014-08 Srodowisko pracy – powietrze Stezenie chlorowodoru\nZakres (0,5 – 10) mg/m3\nMetoda turbidymetryczna PN-Z-04450:2014-08","categories":["environment"],"row_index":63,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,5 – 10) mg/m3"}],"search_zh":"工作场所环境 — 空气 氯化氢浓度 浊度法 范围 PN-Z-04450:2014-08","test_object_zh":"工作场所环境 — 空气","technique_zh":"浊度法","methodology_zh":"氯化氢浓度"},{"_id":"6a864bdffbf98dd0af9b1ecf","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie związków chromu (VI) w przeliczeniu na Cr (VI)","parameters":[{"name":"Zakres","range":"(0,0016 – 0,314) mg/m3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie związków chromu (VI) w przeliczeniu na Cr (VI)\nZakres (0,0016 – 0,314) mg/m3\nMetoda spektrofotometryczna","reference":"PN-87/Z-04126.02","norm_bases":["PN-87/Z-04126.02"],"lab_section":"Pracownia Zagrożeń Chemicznych i Pyłowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie związków chromu (VI) w przeliczeniu na Cr (VI)\nZakres (0,0016 – 0,314) mg/m3\nMetoda spektrofotometryczna PN-87/Z-04126.02 Srodowisko pracy – powietrze Stezenie zwiazkow chromu (VI) w przeliczeniu na Cr (VI)\nZakres (0,0016 – 0,314) mg/m3\nMetoda spektrofotometryczna PN-87/Z-04126.02","categories":["environment"],"row_index":64,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,0016 – 0,314) mg/m3"}],"search_zh":"工作场所环境 — 空气 分光光度法 范围 PN-87/Z-04126.02","technique_zh":"分光光度法","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a864bdffbf98dd0af9b1ed0","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie 4,4’-dwuizocyjanianodwufenylometanu w przeliczeniu na grupę NCO","parameters":[{"name":"Zakres","range":"(0,0014 – 0,056) mg/m3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie 4,4’-dwuizocyjanianodwufenylometanu w przeliczeniu na grupę NCO\nZakres (0,0014 – 0,056) mg/m3\nMetoda spektrofotometryczna","reference":"PN-81/Z-04131.02","norm_bases":["PN-81/Z-04131.02"],"lab_section":"Pracownia Zagrożeń Chemicznych i Pyłowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie 4,4’-dwuizocyjanianodwufenylometanu w przeliczeniu na grupę NCO\nZakres (0,0014 – 0,056) mg/m3\nMetoda spektrofotometryczna PN-81/Z-04131.02 Srodowisko pracy – powietrze Stezenie 4,4’-dwuizocyjanianodwufenylometanu w przeliczeniu na grupe NCO\nZakres (0,0014 – 0,056) mg/m3\nMetoda spektrofotometryczna PN-81/Z-04131.02","categories":["environment"],"row_index":65,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,0014 – 0,056) mg/m3"}],"search_zh":"工作场所环境 — 空气 分光光度法 范围 PN-81/Z-04131.02","technique_zh":"分光光度法","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a864bdffbf98dd0af9b1ed1","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie olejów mineralnych wysokorafinowanych z wyłączeniem cieczy obróbkowych","parameters":[{"name":"Zakres","range":"(0,3 – 24,2) mg/m3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie olejów mineralnych wysokorafinowanych z wyłączeniem cieczy obróbkowych\nZakres (0,3 – 24,2) mg/m3\nMetoda spektrofotometryczna","reference":"PN-Z-04108-6:2006","norm_bases":["PN-Z-04108-6:2006"],"lab_section":"Pracownia Zagrożeń Chemicznych i Pyłowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie olejów mineralnych wysokorafinowanych z wyłączeniem cieczy obróbkowych\nZakres (0,3 – 24,2) mg/m3\nMetoda spektrofotometryczna PN-Z-04108-6:2006 Srodowisko pracy – powietrze Stezenie olejow mineralnych wysokorafinowanych z wylaczeniem cieczy obrobkowych\nZakres (0,3 – 24,2) mg/m3\nMetoda spektrofotometryczna PN-Z-04108-6:2006","categories":["environment","petro"],"row_index":66,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,3 – 24,2) mg/m3"}],"search_zh":"工作场所环境 — 空气 分光光度法 范围 PN-Z-04108-6:2006","technique_zh":"分光光度法","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a864bdffbf98dd0af9b1ed2","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie ozonu","parameters":[{"name":"Zakres","range":"(0,025 – 0,5) mg/m3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie ozonu\nZakres (0,025 – 0,5) mg/m3\nMetoda spektrofotometryczna","reference":"PN-Z-04007-2:1994","norm_bases":["PN-Z-04007-2:1994"],"lab_section":"Pracownia Zagrożeń Chemicznych i Pyłowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie ozonu\nZakres (0,025 – 0,5) mg/m3\nMetoda spektrofotometryczna PN-Z-04007-2:1994 Srodowisko pracy – powietrze Stezenie ozonu\nZakres (0,025 – 0,5) mg/m3\nMetoda spektrofotometryczna PN-Z-04007-2:1994","categories":["environment"],"row_index":67,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,025 – 0,5) mg/m3"}],"search_zh":"工作场所环境 — 空气 臭氧浓度 分光光度法 范围 PN-Z-04007-2:1994","technique_zh":"分光光度法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"臭氧浓度"},{"_id":"6a864bdffbf98dd0af9b1ed3","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie chloru","parameters":[{"name":"Zakres","range":"(0,25 – 1,7) mg/m3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chloru\nZakres (0,25 – 1,7) mg/m3\nMetoda spektrofotometryczna","reference":"PN-Z-04037-03:1975","norm_bases":["PN-Z-04037-03:1975"],"lab_section":"Pracownia Zagrożeń Chemicznych i Pyłowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie chloru\nZakres (0,25 – 1,7) mg/m3\nMetoda spektrofotometryczna PN-Z-04037-03:1975 Srodowisko pracy – powietrze Stezenie chloru\nZakres (0,25 – 1,7) mg/m3\nMetoda spektrofotometryczna PN-Z-04037-03:1975","categories":["environment"],"row_index":68,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,25 – 1,7) mg/m3"}],"search_zh":"工作场所环境 — 空气 氯浓度 分光光度法 范围 PN-Z-04037-03:1975","technique_zh":"分光光度法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"氯浓度"},{"_id":"6a864bdffbf98dd0af9b1ed4","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie siarkowodoru","parameters":[{"name":"Zakres","range":"(0,13 – 16,67) mg/m3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie siarkowodoru\nZakres (0,13 – 16,67) mg/m3\nMetoda spektrofotometryczna","reference":"PN-Z-04015-13:1996","norm_bases":["PN-Z-04015-13:1996"],"lab_section":"Pracownia Zagrożeń Chemicznych i Pyłowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie siarkowodoru\nZakres (0,13 – 16,67) mg/m3\nMetoda spektrofotometryczna PN-Z-04015-13:1996 Srodowisko pracy – powietrze Stezenie siarkowodoru\nZakres (0,13 – 16,67) mg/m3\nMetoda spektrofotometryczna PN-Z-04015-13:1996","categories":["environment"],"row_index":69,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,13 – 16,67) mg/m3"}],"search_zh":"工作场所环境 — 空气 硫化氢浓度 分光光度法 范围 PN-Z-04015-13:1996","technique_zh":"分光光度法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"硫化氢浓度"},{"_id":"6a864bdffbf98dd0af9b1ed5","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie ditlenku siarki","parameters":[{"name":"Zakres","range":"(0,16 – 6,4) mg/m3"},{"name":"Zakres","range":"(0,060 – 2,41) ppm"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie ditlenku siarki\nZakres:\nZakres (0,16 – 6,4) mg/m3\nZakres (0,060 – 2,41) ppm\nMetoda spektrofotometryczna","reference":"PN-Z-04015-12:1996","norm_bases":["PN-Z-04015-12:1996"],"lab_section":"Pracownia Zagrożeń Chemicznych i Pyłowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie ditlenku siarki\nZakres:\nZakres (0,16 – 6,4) mg/m3\nZakres (0,060 – 2,41) ppm\nMetoda spektrofotometryczna PN-Z-04015-12:1996 Srodowisko pracy – powietrze Stezenie ditlenku siarki\nZakres:\nZakres (0,16 – 6,4) mg/m3\nZakres (0,060 – 2,41) ppm\nMetoda spektrofotometryczna PN-Z-04015-12:1996","categories":["environment"],"row_index":70,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,16 – 6,4) mg/m3"},{"name":"范围","range":"(0,060 – 2,41) ppm"}],"search_zh":"工作场所环境 — 空气 二氧化硫浓度 分光光度法 范围 范围 PN-Z-04015-12:1996","technique_zh":"分光光度法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"二氧化硫浓度"},{"_id":"6a864bdffbf98dd0af9b1ed6","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie dekatlenku tetrafosforu","parameters":[{"name":"Zakres","range":"(0,05 – 10,00) mg/m3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie dekatlenku tetrafosforu\nZakres (0,05 – 10,00) mg/m3\nMetoda spektrofotometryczna","reference":"PN-Z-04073-1:2014-08","norm_bases":["PN-Z-04073-1:2014-08"],"lab_section":"Pracownia Zagrożeń Chemicznych i Pyłowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie dekatlenku tetrafosforu\nZakres (0,05 – 10,00) mg/m3\nMetoda spektrofotometryczna PN-Z-04073-1:2014-08 Srodowisko pracy – powietrze Stezenie dekatlenku tetrafosforu\nZakres (0,05 – 10,00) mg/m3\nMetoda spektrofotometryczna PN-Z-04073-1:2014-08","categories":["environment"],"row_index":71,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,05 – 10,00) mg/m3"}],"search_zh":"工作场所环境 — 空气 分光光度法 范围 PN-Z-04073-1:2014-08","technique_zh":"分光光度法","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a864bdffbf98dd0af9b1ed7","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie kwasu fosforowego V","parameters":[{"name":"Zakres","range":"(0,069 – 13,8) mg/m3"}],"technique":"Metoda spektrofotometryczna (z obliczeń)","techniques":["Metoda spektrofotometryczna (z obliczeń)"],"computed":[],"activity":"Stężenie kwasu fosforowego V\nZakres (0,069 – 13,8) mg/m3\nMetoda spektrofotometryczna (z obliczeń)","reference":"PN-Z-04073-1:2014-08","norm_bases":["PN-Z-04073-1:2014-08"],"lab_section":"Pracownia Zagrożeń Chemicznych i Pyłowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie kwasu fosforowego V\nZakres (0,069 – 13,8) mg/m3\nMetoda spektrofotometryczna (z obliczeń) PN-Z-04073-1:2014-08 Srodowisko pracy – powietrze Stezenie kwasu fosforowego V\nZakres (0,069 – 13,8) mg/m3\nMetoda spektrofotometryczna (z obliczen) PN-Z-04073-1:2014-08","categories":["environment"],"row_index":72,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,069 – 13,8) mg/m3"}],"search_zh":"工作场所环境 — 空气 范围 PN-Z-04073-1:2014-08","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a864bdffbf98dd0af9b1ed8","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie dichlorometanu","parameters":[{"name":"Zakres","range":"(5,92 – 621,00) mg/m3"},{"name":"Zakres","range":"(1,67 – 176,2) ppm"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie dichlorometanu\nZakres:\nZakres (5,92 – 621,00) mg/m3\nZakres (1,67 – 176,2) ppm\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04437:2011","norm_bases":["PN-Z-04437:2011"],"lab_section":"Pracownia Zagrożeń Chemicznych i Pyłowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie dichlorometanu\nZakres:\nZakres (5,92 – 621,00) mg/m3\nZakres (1,67 – 176,2) ppm\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04437:2011 Srodowisko pracy – powietrze Stezenie dichlorometanu\nZakres:\nZakres (5,92 – 621,00) mg/m3\nZakres (1,67 – 176,2) ppm\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04437:2011","categories":["environment"],"row_index":73,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(5,92 – 621,00) mg/m3"},{"name":"范围","range":"(1,67 – 176,2) ppm"}],"search_zh":"工作场所环境 — 空气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04437:2011","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a864bdffbf98dd0af9b1ed9","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie etanolu","parameters":[{"name":"Zakres","range":"(5,44 – 7760,00) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie etanolu\nZakres (5,44 – 7760,00) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04140-02:1985","norm_bases":["PN-Z-04140-02:1985"],"lab_section":"Pracownia Zagrożeń Chemicznych i Pyłowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie etanolu\nZakres (5,44 – 7760,00) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04140-02:1985 Srodowisko pracy – powietrze Stezenie etanolu\nZakres (5,44 – 7760,00) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04140-02:1985","categories":["environment"],"row_index":74,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(5,44 – 7760,00) mg/m3"}],"search_zh":"工作场所环境 — 空气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-Z-04140-02:1985","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a864bdffbf98dd0af9b1eda","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie metanolu","parameters":[{"name":"Zakres","range":"(5,25 – 800,00) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie metanolu\nZakres (5,25 – 800,00) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04476:2016-10","norm_bases":["PN-Z-04476:2016-10"],"lab_section":"Pracownia Zagrożeń Chemicznych i Pyłowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie metanolu\nZakres (5,25 – 800,00) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04476:2016-10 Srodowisko pracy – powietrze Stezenie metanolu\nZakres (5,25 – 800,00) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04476:2016-10","categories":["environment"],"row_index":75,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(5,25 – 800,00) mg/m3"}],"search_zh":"工作场所环境 — 空气 甲醇浓度 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-Z-04476:2016-10","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气","methodology_zh":"甲醇浓度"},{"_id":"6a864bdffbf98dd0af9b1edb","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie cykloheksanu","parameters":[{"name":"Zakres","range":"(5,1 – 2000,00) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie cykloheksanu\nZakres (5,1 – 2000,00) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04151-02:1986","norm_bases":["PN-Z-04151-02:1986"],"lab_section":"Pracownia Zagrożeń Chemicznych i Pyłowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie cykloheksanu\nZakres (5,1 – 2000,00) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04151-02:1986 Srodowisko pracy – powietrze Stezenie cykloheksanu\nZakres (5,1 – 2000,00) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04151-02:1986","categories":["environment"],"row_index":76,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(5,1 – 2000,00) mg/m3"}],"search_zh":"工作场所环境 — 空气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-Z-04151-02:1986","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a864bdffbf98dd0af9b1edc","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie heptanu","parameters":[{"name":"Zakres","range":"(4,35 – 2000,00) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie heptanu\nZakres (4,35 – 2000,00) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04138-02:1984","norm_bases":["PN-Z-04138-02:1984"],"lab_section":"Pracownia Zagrożeń Chemicznych i Pyłowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie heptanu\nZakres (4,35 – 2000,00) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04138-02:1984 Srodowisko pracy – powietrze Stezenie heptanu\nZakres (4,35 – 2000,00) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04138-02:1984","categories":["environment"],"row_index":77,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(4,35 – 2000,00) mg/m3"}],"search_zh":"工作场所环境 — 空气 正庚烷浓度 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-Z-04138-02:1984","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气","methodology_zh":"正庚烷浓度"},{"_id":"6a864bdffbf98dd0af9b1edd","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie kumenu","parameters":[{"name":"Zakres","range":"(5,60 – 832,00) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie kumenu\nZakres (5,60 – 832,00) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04016-6:1998","norm_bases":["PN-Z-04016-6:1998"],"lab_section":"Pracownia Zagrożeń Chemicznych i Pyłowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie kumenu\nZakres (5,60 – 832,00) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04016-6:1998 Srodowisko pracy – powietrze Stezenie kumenu\nZakres (5,60 – 832,00) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04016-6:1998","categories":["environment"],"row_index":78,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(5,60 – 832,00) mg/m3"}],"search_zh":"工作场所环境 — 空气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-Z-04016-6:1998","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a864bdffbf98dd0af9b1ede","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie benzyny do lakierów","parameters":[{"name":"Zakres","range":"(10,67 – 2000,00) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie benzyny do lakierów\nZakres (10,67 – 2000,00) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04134-03:1981","norm_bases":["PN-Z-04134-03:1981"],"lab_section":"Pracownia Zagrożeń Chemicznych i Pyłowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie benzyny do lakierów\nZakres (10,67 – 2000,00) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04134-03:1981 Srodowisko pracy – powietrze Stezenie benzyny do lakierow\nZakres (10,67 – 2000,00) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04134-03:1981","categories":["environment","automotive"],"row_index":79,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(10,67 – 2000,00) mg/m3"}],"search_zh":"工作场所环境 — 空气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-Z-04134-03:1981","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a864bdffbf98dd0af9b1edf","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie benzenu","parameters":[{"name":"Zakres","range":"(0,063 – 13,5) mg/m3"},{"name":"Zakres","range":"(0,019 – 4,17) ppm"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie benzenu\nZakres:\nZakres (0,063 – 13,5) mg/m3\nZakres (0,019 – 4,17) ppm\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04016-10:2005","norm_bases":["PN-Z-04016-10:2005"],"lab_section":"Pracownia Zagrożeń Chemicznych i Pyłowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie benzenu\nZakres:\nZakres (0,063 – 13,5) mg/m3\nZakres (0,019 – 4,17) ppm\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04016-10:2005 Srodowisko pracy – powietrze Stezenie benzenu\nZakres:\nZakres (0,063 – 13,5) mg/m3\nZakres (0,019 – 4,17) ppm\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04016-10:2005","categories":["environment"],"row_index":80,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,063 – 13,5) mg/m3"},{"name":"范围","range":"(0,019 – 4,17) ppm"}],"search_zh":"工作场所环境 — 空气 苯浓度 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04016-10:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气","methodology_zh":"苯浓度"},{"_id":"6a864bdffbf98dd0af9b1ee0","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie toluenu","parameters":[{"name":"Zakres","range":"(0,83 – 1346,0) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie toluenu\nZakres (0,83 – 1346,0) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04115-01:1978","norm_bases":["PN-Z-04115-01:1978"],"lab_section":"Pracownia Zagrożeń Chemicznych i Pyłowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie toluenu\nZakres (0,83 – 1346,0) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04115-01:1978 Srodowisko pracy – powietrze Stezenie toluenu\nZakres (0,83 – 1346,0) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04115-01:1978","categories":["environment"],"row_index":81,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,83 – 1346,0) mg/m3"}],"search_zh":"工作场所环境 — 空气 甲苯浓度 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-Z-04115-01:1978","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气","methodology_zh":"甲苯浓度"},{"_id":"6a864bdffbf98dd0af9b1ee1","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie ksylenu (izomery)","parameters":[{"name":"Zakres","range":"(2,5 – 3986,0) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie ksylenu (izomery)\nZakres (2,5 – 3986,0) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04116-01:1978","norm_bases":["PN-Z-04116-01:1978"],"lab_section":"Pracownia Zagrożeń Chemicznych i Pyłowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie ksylenu (izomery)\nZakres (2,5 – 3986,0) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04116-01:1978 Srodowisko pracy – powietrze Stezenie ksylenu (izomery)\nZakres (2,5 – 3986,0) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04116-01:1978","categories":["environment"],"row_index":82,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(2,5 – 3986,0) mg/m3"}],"search_zh":"工作场所环境 — 空气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-Z-04116-01:1978","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a864bdffbf98dd0af9b1ee2","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie etylobenzenu","parameters":[{"name":"Zakres","range":"(0,87 – 1374,0) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie etylobenzenu\nZakres (0,87 – 1374,0) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04081-01:1979","norm_bases":["PN-Z-04081-01:1979"],"lab_section":"Pracownia Zagrożeń Chemicznych i Pyłowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie etylobenzenu\nZakres (0,87 – 1374,0) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04081-01:1979 Srodowisko pracy – powietrze Stezenie etylobenzenu\nZakres (0,87 – 1374,0) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04081-01:1979","categories":["environment"],"row_index":83,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,87 – 1374,0) mg/m3"}],"search_zh":"工作场所环境 — 空气 乙苯浓度 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-Z-04081-01:1979","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气","methodology_zh":"乙苯浓度"},{"_id":"6a864bdffbf98dd0af9b1ee3","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie trimetylobenzenu (izomery)","parameters":[{"name":"Zakres","range":"(2,93 – 4666,0) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie trimetylobenzenu (izomery)\nZakres (2,93 – 4666,0) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04016-4:1998","norm_bases":["PN-Z-04016-4:1998"],"lab_section":"Pracownia Zagrożeń Chemicznych i Pyłowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie trimetylobenzenu (izomery)\nZakres (2,93 – 4666,0) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04016-4:1998 Srodowisko pracy – powietrze Stezenie trimetylobenzenu (izomery)\nZakres (2,93 – 4666,0) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04016-4:1998","categories":["environment"],"row_index":84,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(2,93 – 4666,0) mg/m3"}],"search_zh":"工作场所环境 — 空气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-Z-04016-4:1998","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a864bdffbf98dd0af9b1ee4","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie octanu n-butylu","parameters":[{"name":"Zakres","range":"(0,97– 1574,0) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie octanu n-butylu\nZakres (0,97– 1574,0) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04119-01:1978","norm_bases":["PN-Z-04119-01:1978"],"lab_section":"Pracownia Zagrożeń Chemicznych i Pyłowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie octanu n-butylu\nZakres (0,97– 1574,0) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04119-01:1978 Srodowisko pracy – powietrze Stezenie octanu n-butylu\nZakres (0,97– 1574,0) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04119-01:1978","categories":["environment"],"row_index":85,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,97– 1574,0) mg/m3"}],"search_zh":"工作场所环境 — 空气 乙酸正丁酯浓度 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-Z-04119-01:1978","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气","methodology_zh":"乙酸正丁酯浓度"},{"_id":"6a864bdffbf98dd0af9b1ee5","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie octanu etylu","parameters":[{"name":"Zakres","range":"(0,97 – 1534,0) mg/m3"},{"name":"Zakres","range":"(0,265 – 419,60) ppm"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie octanu etylu\nZakres:\nZakres (0,97 – 1534,0) mg/m3\nZakres (0,265 – 419,60) ppm\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04119-01:1978","norm_bases":["PN-Z-04119-01:1978"],"lab_section":"Pracownia Zagrożeń Chemicznych i Pyłowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie octanu etylu\nZakres:\nZakres (0,97 – 1534,0) mg/m3\nZakres (0,265 – 419,60) ppm\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04119-01:1978 Srodowisko pracy – powietrze Stezenie octanu etylu\nZakres:\nZakres (0,97 – 1534,0) mg/m3\nZakres (0,265 – 419,60) ppm\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04119-01:1978","categories":["environment"],"row_index":86,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,97 – 1534,0) mg/m3"},{"name":"范围","range":"(0,265 – 419,60) ppm"}],"search_zh":"工作场所环境 — 空气 乙酸乙酯浓度 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04119-01:1978","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气","methodology_zh":"乙酸乙酯浓度"},{"_id":"6a864bdffbf98dd0af9b1ee6","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie butan-1-olu","parameters":[{"name":"Zakres","range":"(0,83 – 1306,0) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie butan-1-olu\nZakres (0,83 – 1306,0) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04155-3:1994","norm_bases":["PN-Z-04155-3:1994"],"lab_section":"Pracownia Zagrożeń Chemicznych i Pyłowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie butan-1-olu\nZakres (0,83 – 1306,0) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04155-3:1994 Srodowisko pracy – powietrze Stezenie butan-1-olu\nZakres (0,83 – 1306,0) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04155-3:1994","categories":["environment"],"row_index":87,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,83 – 1306,0) mg/m3"}],"search_zh":"工作场所环境 — 空气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-Z-04155-3:1994","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a864bdffbf98dd0af9b1ee7","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie propan-2-olu","parameters":[{"name":"Zakres","range":"(0,87 –1360,0) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie propan-2-olu\nZakres (0,87 –1360,0) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04224-02:1992","norm_bases":["PN-Z-04224-02:1992"],"lab_section":"Pracownia Zagrożeń Chemicznych i Pyłowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie propan-2-olu\nZakres (0,87 –1360,0) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04224-02:1992 Srodowisko pracy – powietrze Stezenie propan-2-olu\nZakres (0,87 –1360,0) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04224-02:1992","categories":["environment"],"row_index":88,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,87 –1360,0) mg/m3"}],"search_zh":"工作场所环境 — 空气 异丙醇浓度 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-Z-04224-02:1992","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气","methodology_zh":"异丙醇浓度"},{"_id":"6a864bdffbf98dd0af9b1ee8","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie acetonu","parameters":[{"name":"Zakres","range":"(0,80 –1240,0) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie acetonu\nZakres (0,80 –1240,0) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04057-01:1979","norm_bases":["PN-Z-04057-01:1979"],"lab_section":"Pracownia Zagrożeń Chemicznych i Pyłowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie acetonu\nZakres (0,80 –1240,0) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04057-01:1979 Srodowisko pracy – powietrze Stezenie acetonu\nZakres (0,80 –1240,0) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04057-01:1979","categories":["environment"],"row_index":89,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,80 –1240,0) mg/m3"}],"search_zh":"工作场所环境 — 空气 丙酮浓度 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-Z-04057-01:1979","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气","methodology_zh":"丙酮浓度"},{"_id":"6a864bdffbf98dd0af9b1ee9","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie butan-2-onu","parameters":[{"name":"Zakres","range":"(0,83 – 1346,0) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie butan-2-onu\nZakres (0,83 – 1346,0) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04107-02:1979","norm_bases":["PN-Z-04107-02:1979"],"lab_section":"Pracownia Zagrożeń Chemicznych i Pyłowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie butan-2-onu\nZakres (0,83 – 1346,0) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04107-02:1979 Srodowisko pracy – powietrze Stezenie butan-2-onu\nZakres (0,83 – 1346,0) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04107-02:1979","categories":["environment"],"row_index":90,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,83 – 1346,0) mg/m3"}],"search_zh":"工作场所环境 — 空气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-Z-04107-02:1979","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a864bdffbf98dd0af9b1eea","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie 4-metylopentan-2-onu","parameters":[{"name":"Zakres","range":"(0,90 – 1440,0) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie 4-metylopentan-2-onu\nZakres (0,90 – 1440,0) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04165-02:1986","norm_bases":["PN-Z-04165-02:1986"],"lab_section":"Pracownia Zagrożeń Chemicznych i Pyłowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie 4-metylopentan-2-onu\nZakres (0,90 – 1440,0) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04165-02:1986 Srodowisko pracy – powietrze Stezenie 4-metylopentan-2-onu\nZakres (0,90 – 1440,0) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04165-02:1986","categories":["environment"],"row_index":91,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,90 – 1440,0) mg/m3"}],"search_zh":"工作场所环境 — 空气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-Z-04165-02:1986","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a864bdffbf98dd0af9b1eeb","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie tetrachloroetenu","parameters":[{"name":"Zakres","range":"(1,03 – 1640,0) mg/m3"},{"name":"Zakres","range":"(0,150 – 238,35) ppm"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie tetrachloroetenu\nZakres:\nZakres (1,03 – 1640,0) mg/m3\nZakres (0,150 – 238,35) ppm\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04118-01:1978","norm_bases":["PN-Z-04118-01:1978"],"lab_section":"Pracownia Zagrożeń Chemicznych i Pyłowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie tetrachloroetenu\nZakres:\nZakres (1,03 – 1640,0) mg/m3\nZakres (0,150 – 238,35) ppm\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04118-01:1978 Srodowisko pracy – powietrze Stezenie tetrachloroetenu\nZakres:\nZakres (1,03 – 1640,0) mg/m3\nZakres (0,150 – 238,35) ppm\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04118-01:1978","categories":["environment"],"row_index":92,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(1,03 – 1640,0) mg/m3"},{"name":"范围","range":"(0,150 – 238,35) ppm"}],"search_zh":"工作场所环境 — 空气 四氯乙烯浓度 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04118-01:1978","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气","methodology_zh":"四氯乙烯浓度"},{"_id":"6a864bdffbf98dd0af9b1eec","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie trichloroetenu","parameters":[{"name":"Zakres","range":"(0,84 – 1500,0) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie trichloroetenu\nZakres (0,84 – 1500,0) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04047-02:1978","norm_bases":["PN-Z-04047-02:1978"],"lab_section":"Pracownia Zagrożeń Chemicznych i Pyłowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie trichloroetenu\nZakres (0,84 – 1500,0) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04047-02:1978 Srodowisko pracy – powietrze Stezenie trichloroetenu\nZakres (0,84 – 1500,0) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04047-02:1978","categories":["environment"],"row_index":93,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,84 – 1500,0) mg/m3"}],"search_zh":"工作场所环境 — 空气 三氯乙烯浓度 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-Z-04047-02:1978","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气","methodology_zh":"三氯乙烯浓度"},{"_id":"6a864bdffbf98dd0af9b1eed","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie benzyny ekstrakcyjnej","parameters":[{"name":"Zakres","range":"(1,67 – 1600,0) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie benzyny ekstrakcyjnej\nZakres (1,67 – 1600,0) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04134-02:1981","norm_bases":["PN-Z-04134-02:1981"],"lab_section":"Pracownia Zagrożeń Chemicznych i Pyłowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie benzyny ekstrakcyjnej\nZakres (1,67 – 1600,0) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04134-02:1981 Srodowisko pracy – powietrze Stezenie benzyny ekstrakcyjnej\nZakres (1,67 – 1600,0) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04134-02:1981","categories":["environment"],"row_index":94,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(1,67 – 1600,0) mg/m3"}],"search_zh":"工作场所环境 — 空气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-Z-04134-02:1981","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a864bdffbf98dd0af9b1eee","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie nafty","parameters":[{"name":"Zakres","range":"(1,67 – 1333,0) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie nafty\nZakres (1,67 – 1333,0) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04227-02:1992","norm_bases":["PN-Z-04227-02:1992"],"lab_section":"Pracownia Zagrożeń Chemicznych i Pyłowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie nafty\nZakres (1,67 – 1333,0) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04227-02:1992 Srodowisko pracy – powietrze Stezenie nafty\nZakres (1,67 – 1333,0) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04227-02:1992","categories":["environment"],"row_index":95,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(1,67 – 1333,0) mg/m3"}],"search_zh":"工作场所环境 — 空气 煤油浓度 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-Z-04227-02:1992","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气","methodology_zh":"煤油浓度"},{"_id":"6a864bdffbf98dd0af9b1eef","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie gazów:","parameters":[{"name":"CO","range":"(2,34 – 176,5) mg/m3"},{"name":"Zakres","range":"(2 – 152) ppm"},{"name":"NO","range":"(0,26 – 3,1) mg/m3"},{"name":"(0,2 – 2,5) ppm"},{"name":"NO2","range":"(0,19 – 2,88) mg/m3"},{"name":"(0,1 – 1,5) ppm"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Stężenie gazów:\nZakres:\nCO (2,34 – 176,5) mg/m3\nZakres (2 – 152) ppm\nNO (0,26 – 3,1) mg/m3\n(0,2 – 2,5) ppm\nNO2 (0,19 – 2,88) mg/m3\n(0,1 – 1,5) ppm\nMetoda elektrochemiczna","reference":"PB-05 wydanie 5 z dnia 13.05.2026 r.","norm_bases":["PB-05 wydanie 5 z dnia 13.05.2026 r."],"lab_section":"Pracownia Zagrożeń Chemicznych i Pyłowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie gazów:\nZakres:\nCO (2,34 – 176,5) mg/m3\nZakres (2 – 152) ppm\nNO (0,26 – 3,1) mg/m3\n(0,2 – 2,5) ppm\nNO2 (0,19 – 2,88) mg/m3\n(0,1 – 1,5) ppm\nMetoda elektrochemiczna PB-05 wydanie 5 z dnia 13.05.2026 r. Srodowisko pracy – powietrze Stezenie gazow:\nZakres:\nCO (2,34 – 176,5) mg/m3\nZakres (2 – 152) ppm\nNO (0,26 – 3,1) mg/m3\n(0,2 – 2,5) ppm\nNO2 (0,19 – 2,88) mg/m3\n(0,1 – 1,5) ppm\nMetoda elektrochemiczna PB-05 wydanie 5 z dnia 13.05.2026 r.","categories":["environment"],"row_index":96,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"CO","range":"(2,34 – 176,5) mg/m3"},{"name":"范围","range":"(2 – 152) ppm"},{"name":"NO","range":"(0,26 – 3,1) mg/m3"},{"name":"(0,2 – 2,5) ppm"},{"name":"NO2","range":"(0,19 – 2,88) mg/m3"},{"name":"(0,1 – 1,5) ppm"}],"search_zh":"工作场所环境 — 空气 气体浓度： 电化学法 CO 范围 NO NO2 PB-05 wydanie 5 z dnia 13.05.2026 r.","technique_zh":"电化学法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"气体浓度："},{"_id":"6a864bdffbf98dd0af9b1ef0","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Wskaźniki narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźniki narażenia (z obliczeń)","reference":"PB-05 wydanie 5 z dnia 13.05.2026 r.","norm_bases":["PB-05 wydanie 5 z dnia 13.05.2026 r."],"lab_section":"Pracownia Zagrożeń Chemicznych i Pyłowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Wskaźniki narażenia (z obliczeń) PB-05 wydanie 5 z dnia 13.05.2026 r. Srodowisko pracy – powietrze Wskazniki narazenia (z obliczen) PB-05 wydanie 5 z dnia 13.05.2026 r.","categories":["environment"],"row_index":97,"parse_version":4,"parse_source":"agent-claude-code","search_zh":"工作场所环境 — 空气 暴露指数（计算值） PB-05 wydanie 5 z dnia 13.05.2026 r.","test_object_zh":"工作场所环境 — 空气","methodology_zh":"暴露指数（计算值）"},{"_id":"6a864bdffbf98dd0af9b1ef1","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"","reference":"Wersja strony: A","norm_bases":["Wersja strony: A"],"lab_section":"Pracownia Zagrożeń Chemicznych i Pyłowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Wersja strony: A Srodowisko pracy – powietrze Wersja strony: A","categories":["environment"],"row_index":98,"parse_version":4,"parse_source":"agent-claude-code","search_zh":"工作场所环境 — 空气 Wersja strony: A","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a864bdffbf98dd0af9b1ef2","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna","parameters":[{"name":"Apatyty i fosforyty"},{"name":"Asfalt naftowy"},{"name":"Cement portlandzki"},{"name":"Ditlenek tytanu"},{"name":"Grafit naturalny"},{"name":"Grafit syntetyczny"},{"name":"Kaolin"},{"name":"Krzemionka bezpostaciowa i syntetyczna"},{"name":"Pyły drewna"},{"name":"Pyły mąki"},{"name":"Pyły niesklasyfikowane ze względu na toksyczność"},{"name":"Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Sadza techniczna"},{"name":"Siarczan wapnia (gips)"},{"name":"Talk"},{"name":"Węgiel (kamienny, brunatny)"},{"name":"Węglan magnezu wapnia (dolomit)"},{"name":"Węglik krzemu niewłóknisty"},{"name":"Zakres","range":"(0,18 – 43,0) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna\nZakres:\nApatyty i fosforyty\nAsfalt naftowy\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna\nPyły drewna\nPyły mąki\nPyły niesklasyfikowane ze względu na toksyczność\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nSadza techniczna\nSiarczan wapnia (gips)\nTalk\nWęgiel (kamienny, brunatny)\nWęglan magnezu wapnia (dolomit)\nWęglik krzemu niewłóknisty\nZakres (0,18 – 43,0) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04507:2022-05","PN-Z-04507:2022-05/Ap1:2022-08"],"lab_section":"Pracownia Zagrożeń Chemicznych i Pyłowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna\nZakres:\nApatyty i fosforyty\nAsfalt naftowy\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna\nPyły drewna\nPyły mąki\nPyły niesklasyfikowane ze względu na toksyczność\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nSadza techniczna\nSiarczan wapnia (gips)\nTalk\nWęgiel (kamienny, brunatny)\nWęglan magnezu wapnia (dolomit)\nWęglik krzemu niewłóknisty\nZakres (0,18 – 43,0) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08 Srodowisko pracy – powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia - frakcja wdychalna\nZakres:\nApatyty i fosforyty\nAsfalt naftowy\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna\nPyly drewna\nPyly maki\nPyly niesklasyfikowane ze wzgledu na toksycznosc\nPyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nSadza techniczna\nSiarczan wapnia (gips)\nTalk\nWegiel (kamienny, brunatny)\nWeglan magnezu wapnia (dolomit)\nWeglik krzemu niewloknisty\nZakres (0,18 – 43,0) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":99,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"磷灰石与磷块岩"},{"name":"石油沥青"},{"name":"硅酸盐水泥"},{"name":"二氧化钛"},{"name":"天然石墨"},{"name":"合成石墨"},{"name":"高岭土"},{"name":"无定形与合成二氧化硅"},{"name":"木粉尘"},{"name":"面粉粉尘"},{"name":"未按毒性分类的粉尘"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"炭黑"},{"name":"Siarczan wapnia (gips)"},{"name":"滑石"},{"name":"煤（烟煤、褐煤）"},{"name":"碳酸钙镁（白云石）"},{"name":"非纤维状碳化硅"},{"name":"范围","range":"(0,18 – 43,0) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害粉尘因素浓度 — 可吸入组分 重量法 磷灰石与磷块岩 石油沥青 硅酸盐水泥 二氧化钛 天然石墨 合成石墨 高岭土 无定形与合成二氧化硅 木粉尘 面粉粉尘 未按毒性分类的粉尘 动植物来源有机粉尘，木粉和面粉除外 炭黑 滑石 煤（烟煤、褐煤） 碳酸钙镁（白云石） 非纤维状碳化硅 范围 PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"有害粉尘因素浓度 — 可吸入组分"},{"_id":"6a864bdffbf98dd0af9b1ef3","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja respirabilna","parameters":[{"name":"Apatyty i fosforyty"},{"name":"Cement portlandzki"},{"name":"Grafit naturalny"},{"name":"Krzemionka bezpostaciowa i syntetyczna"},{"name":"Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Talk"},{"name":"Węgiel (kamienny, brunatny)"},{"name":"Zakres","range":"(0,10 – 94,2) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja respirabilna\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nTalk\nWęgiel (kamienny, brunatny)\nZakres (0,10 – 94,2) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04508:2022-05","PN-Z-04508:2022-05/Ap1:2022-08"],"lab_section":"Pracownia Zagrożeń Chemicznych i Pyłowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja respirabilna\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nTalk\nWęgiel (kamienny, brunatny)\nZakres (0,10 – 94,2) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08 Srodowisko pracy – powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia - frakcja respirabilna\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nTalk\nWegiel (kamienny, brunatny)\nZakres (0,10 – 94,2) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":100,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"磷灰石与磷块岩"},{"name":"硅酸盐水泥"},{"name":"天然石墨"},{"name":"无定形与合成二氧化硅"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"滑石"},{"name":"煤（烟煤、褐煤）"},{"name":"范围","range":"(0,10 – 94,2) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害粉尘因素浓度 — 呼吸性组分 重量法 磷灰石与磷块岩 硅酸盐水泥 天然石墨 无定形与合成二氧化硅 动植物来源有机粉尘，木粉和面粉除外 滑石 煤（烟煤、褐煤） 范围 PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"有害粉尘因素浓度 — 呼吸性组分"},{"_id":"6a864bdffbf98dd0af9b1ef4","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna","parameters":[{"name":"Węgiel (kamienny, brunatny)"},{"name":"Zakres","range":"(0,20 – 166,67) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna\nZakres:\nWęgiel (kamienny, brunatny)\nZakres (0,20 – 166,67) mg/m3\nMetoda grawimetryczna","reference":"PB-08 wyd. 4 z dnia 15.03.2023 r. | PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","norm_bases":["PB-08 wyd. 4 z dnia 15.03.2023 r.","PN-Z-04507:2022-05","PN-Z-04507:2022-05/Ap1:2022-08"],"lab_section":"Pracownia Zagrożeń Chemicznych i Pyłowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna\nZakres:\nWęgiel (kamienny, brunatny)\nZakres (0,20 – 166,67) mg/m3\nMetoda grawimetryczna PB-08 wyd. 4 z dnia 15.03.2023 r. | PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08 Srodowisko pracy – powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia - frakcja wdychalna\nZakres:\nWegiel (kamienny, brunatny)\nZakres (0,20 – 166,67) mg/m3\nMetoda grawimetryczna PB-08 wyd. 4 z dnia 15.03.2023 r. | PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","categories":["environment"],"row_index":101,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"煤（烟煤、褐煤）"},{"name":"范围","range":"(0,20 – 166,67) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害粉尘因素浓度 — 可吸入组分 重量法 煤（烟煤、褐煤） 范围 PB-08 wyd. 4 z dnia 15.03.2023 r. | PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"有害粉尘因素浓度 — 可吸入组分"},{"_id":"6a864bdffbf98dd0af9b1ef5","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna","parameters":[{"name":"Węgiel (kamienny, brunatny)"},{"name":"Zakres","range":"(0,20 – 166,67) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna\nZakres:\nWęgiel (kamienny, brunatny)\nZakres (0,20 – 166,67) mg/m3\nMetoda grawimetryczna","reference":"PB-08 wyd. 4 z dnia 15.03.2023 r. | PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","norm_bases":["PB-08 wyd. 4 z dnia 15.03.2023 r.","PN-Z-04508:2022-05","PN-Z-04508:2022-05/Ap1:2022-08"],"lab_section":"Pracownia Zagrożeń Chemicznych i Pyłowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna\nZakres:\nWęgiel (kamienny, brunatny)\nZakres (0,20 – 166,67) mg/m3\nMetoda grawimetryczna PB-08 wyd. 4 z dnia 15.03.2023 r. | PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08 Srodowisko pracy – powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia – frakcja respirabilna\nZakres:\nWegiel (kamienny, brunatny)\nZakres (0,20 – 166,67) mg/m3\nMetoda grawimetryczna PB-08 wyd. 4 z dnia 15.03.2023 r. | PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","categories":["environment"],"row_index":102,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"煤（烟煤、褐煤）"},{"name":"范围","range":"(0,20 – 166,67) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害粉尘因素浓度 — 呼吸性组分 重量法 煤（烟煤、褐煤） 范围 PB-08 wyd. 4 z dnia 15.03.2023 r. | PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"有害粉尘因素浓度 — 呼吸性组分"},{"_id":"6a864bdffbf98dd0af9b1ef6","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Pobieranie próbek do oceny narażenia zawodowego na:","parameters":[{"name":"czynniki pyłowe – frakcja wdychalna – frakcja respirabilna"},{"name":"substancje organiczne"},{"name":"substancje nieorganiczne, w tym – frakcja wdychalna – frakcja respirabilna – frakcja torakalna"},{"name":"metale i ich związki, w tym – frakcja wdychalna – frakcja respirabilna"},{"name":"azbest – włókna respirabilne"},{"name":"sztuczne włókna mineralne, z wyjątkiem ogniotrwałych włókien ceramicznych – włókna respirabilne"},{"name":"ogniotrwałe włókna ceramiczne"},{"name":"ogniotrwałe włókna ceramiczne w mieszaninie z innymi sztucznymi włóknami mineralnymi"}],"technique":"Metoda dozymetrii indywidualnej","techniques":["Metoda dozymetrii indywidualnej"],"computed":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe – frakcja wdychalna – frakcja respirabilna\nsubstancje organiczne\nsubstancje nieorganiczne, w tym – frakcja wdychalna – frakcja respirabilna – frakcja torakalna\nmetale i ich związki, w tym – frakcja wdychalna – frakcja respirabilna\nazbest – włókna respirabilne\nsztuczne włókna mineralne, z wyjątkiem ogniotrwałych włókien ceramicznych – włókna respirabilne\nogniotrwałe włókna ceramiczne\nogniotrwałe włókna ceramiczne w mieszaninie z innymi sztucznymi włóknami mineralnymi\nMetoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002+Az1:2004"],"lab_section":"Pracownia Zagrożeń Chemicznych i Pyłowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe – frakcja wdychalna – frakcja respirabilna\nsubstancje organiczne\nsubstancje nieorganiczne, w tym – frakcja wdychalna – frakcja respirabilna – frakcja torakalna\nmetale i ich związki, w tym – frakcja wdychalna – frakcja respirabilna\nazbest – włókna respirabilne\nsztuczne włókna mineralne, z wyjątkiem ogniotrwałych włókien ceramicznych – włókna respirabilne\nogniotrwałe włókna ceramiczne\nogniotrwałe włókna ceramiczne w mieszaninie z innymi sztucznymi włóknami mineralnymi\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy – powietrze Pobieranie probek do oceny narazenia zawodowego na:\nZakres:\nczynniki pylowe – frakcja wdychalna – frakcja respirabilna\nsubstancje organiczne\nsubstancje nieorganiczne, w tym – frakcja wdychalna – frakcja respirabilna – frakcja torakalna\nmetale i ich zwiazki, w tym – frakcja wdychalna – frakcja respirabilna\nazbest – wlokna respirabilne\nsztuczne wlokna mineralne, z wyjatkiem ogniotrwalych wlokien ceramicznych – wlokna respirabilne\nogniotrwale wlokna ceramiczne\nogniotrwale wlokna ceramiczne w mieszaninie z innymi sztucznymi wloknami mineralnymi\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002+Az1:2004","categories":["materials","environment"],"row_index":103,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"职业接触评估采样，针对：","search_zh":"工作场所环境 — 空气 职业接触评估采样，针对： 个体剂量测定法 粉尘因素 — 可吸入组分 — 呼吸性组分 有机物质 无机物质，其中包括 － 可吸入性粉尘 － 呼吸性粉尘 － 胸腔性粉尘 金属及其化合物，包括 — 可吸入组分 — 呼吸性组分 石棉 — 呼吸性纤维 人造矿物纤维，耐火陶瓷纤维除外 － 呼吸性纤维 耐火陶瓷纤维 与其他人造矿物纤维混合的耐火陶瓷纤维 PN-Z-04008-7:2002+Az1:2004","technique_zh":"个体剂量测定法","test_object_zh":"工作场所环境 — 空气","parameters_zh":[{"name":"粉尘因素 — 可吸入组分 — 呼吸性组分"},{"name":"有机物质"},{"name":"无机物质，其中包括 － 可吸入性粉尘 － 呼吸性粉尘 － 胸腔性粉尘"},{"name":"金属及其化合物，包括 — 可吸入组分 — 呼吸性组分"},{"name":"石棉 — 呼吸性纤维"},{"name":"人造矿物纤维，耐火陶瓷纤维除外 － 呼吸性纤维"},{"name":"耐火陶瓷纤维"},{"name":"与其他人造矿物纤维混合的耐火陶瓷纤维"}]},{"_id":"6a864bdffbf98dd0af9b1ef7","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Wskaźnik narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002+Az1:2004"],"lab_section":"Pracownia Zagrożeń Chemicznych i Pyłowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Wskaźnik narażenia (z obliczeń) PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy – powietrze Wskaznik narazenia (z obliczen) PN-Z-04008-7:2002+Az1:2004","categories":["environment"],"row_index":104,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"暴露指数（计算得出）","search_zh":"工作场所环境 — 空气 暴露指数（计算得出） PN-Z-04008-7:2002+Az1:2004","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a864bdffbf98dd0af9b1ef8","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Pobieranie próbek do oceny narażenia zawodowego na:","parameters":[{"name":"substancje organiczne"},{"name":"substancje nieorganiczne, w tym – frakcja wdychalna"}],"technique":"Metoda stacjonarna","techniques":["Metoda stacjonarna"],"computed":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nsubstancje organiczne\nsubstancje nieorganiczne, w tym – frakcja wdychalna\nMetoda stacjonarna","reference":"PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002+Az1:2004"],"lab_section":"Pracownia Zagrożeń Chemicznych i Pyłowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nsubstancje organiczne\nsubstancje nieorganiczne, w tym – frakcja wdychalna\nMetoda stacjonarna PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy – powietrze Pobieranie probek do oceny narazenia zawodowego na:\nZakres:\nsubstancje organiczne\nsubstancje nieorganiczne, w tym – frakcja wdychalna\nMetoda stacjonarna PN-Z-04008-7:2002+Az1:2004","categories":["environment"],"row_index":105,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"职业接触评估采样，针对：","search_zh":"工作场所环境 — 空气 职业接触评估采样，针对： 定点测定法 有机物质 PN-Z-04008-7:2002+Az1:2004","test_object_zh":"工作场所环境 — 空气","parameters_zh":[{"name":"有机物质"},{"name":"substancje nieorganiczne, w tym – frakcja wdychalna"}],"technique_zh":"定点测定法"},{"_id":"6a864bdffbf98dd0af9b1ef9","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Wskaźnik narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002+Az1:2004"],"lab_section":"Pracownia Zagrożeń Chemicznych i Pyłowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Wskaźnik narażenia (z obliczeń) PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy – powietrze Wskaznik narazenia (z obliczen) PN-Z-04008-7:2002+Az1:2004","categories":["environment"],"row_index":106,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"暴露指数（计算得出）","search_zh":"工作场所环境 — 空气 暴露指数（计算得出） PN-Z-04008-7:2002+Az1:2004","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a864bdffbf98dd0af9b1efa","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Pobieranie próbek w podziemnych zakładach górniczych do oceny narażenia zawodowego na:","parameters":[{"name":"czynniki pyłowe – frakcja wdychalna – frakcja respirabilna"}],"technique":"Metoda dozymetrii indywidualnej","techniques":["Metoda dozymetrii indywidualnej"],"computed":[],"activity":"Pobieranie próbek w podziemnych zakładach górniczych do oceny narażenia zawodowego na:\nczynniki pyłowe – frakcja wdychalna – frakcja respirabilna\nMetoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002+Az1:2004 | PN-G-04035:2002+Az1:2005","norm_bases":["PN-Z-04008-7:2002+Az1:2004","PN-G-04035:2002+Az1:2005"],"lab_section":"Pracownia Zagrożeń Chemicznych i Pyłowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Pobieranie próbek w podziemnych zakładach górniczych do oceny narażenia zawodowego na:\nczynniki pyłowe – frakcja wdychalna – frakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002+Az1:2004 | PN-G-04035:2002+Az1:2005 Srodowisko pracy – powietrze Pobieranie probek w podziemnych zakladach gorniczych do oceny narazenia zawodowego na:\nczynniki pylowe – frakcja wdychalna – frakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002+Az1:2004 | PN-G-04035:2002+Az1:2005","categories":["environment"],"row_index":107,"parse_version":4,"parse_source":"agent-claude-code","search_zh":"工作场所环境 — 空气 个体剂量测定法 粉尘因素 — 可吸入组分 — 呼吸性组分 PN-Z-04008-7:2002+Az1:2004 | PN-G-04035:2002+Az1:2005","technique_zh":"个体剂量测定法","test_object_zh":"工作场所环境 — 空气","parameters_zh":[{"name":"粉尘因素 — 可吸入组分 — 呼吸性组分"}]},{"_id":"6a864bdffbf98dd0af9b1efb","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Wskaźnik narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PN-Z-04008-7:2002+Az1:2004 | PN-G-04035:2002+Az1:2005","norm_bases":["PN-Z-04008-7:2002+Az1:2004","PN-G-04035:2002+Az1:2005"],"lab_section":"Pracownia Zagrożeń Chemicznych i Pyłowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Wskaźnik narażenia (z obliczeń) PN-Z-04008-7:2002+Az1:2004 | PN-G-04035:2002+Az1:2005 Srodowisko pracy – powietrze Wskaznik narazenia (z obliczen) PN-Z-04008-7:2002+Az1:2004 | PN-G-04035:2002+Az1:2005","categories":["environment"],"row_index":108,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"暴露指数（计算得出）","search_zh":"工作场所环境 — 空气 暴露指数（计算得出） PN-Z-04008-7:2002+Az1:2004 | PN-G-04035:2002+Az1:2005","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a864bdffbf98dd0af9b1efc","lab_id":"69ad52a3de79e566650fb1cf","country":"PL","accr_number":"AB 340","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie/zawartość krzemionki krystalicznej (kwarc)","parameters":[{"name":"frakcja respirabilna"},{"name":"Zakres","range":"(0,0075 – 5,76) mg/m3"},{"name":"Zakres","range":"(0,0051 – 0,788) mg w próbce"},{"name":"Stężenie/zawartość krzemionki krystalicznej (krystobalit)"},{"name":"frakcja respirabilna"},{"name":"Zakres","range":"(0,0076 – 5,54) mg/m3"},{"name":"Zakres","range":"(0,0052 – 0,758) mg w próbce"}],"technique":"Metoda spektrometrii w zakresie podczerwieni z transformacją Fouriera (FT-IR)","techniques":["Metoda spektrometrii w zakresie podczerwieni z transformacją Fouriera (FT-IR)"],"computed":[],"activity":"Stężenie/zawartość krzemionki krystalicznej (kwarc)\nZakres:\nfrakcja respirabilna\nZakres (0,0075 – 5,76) mg/m3\nZakres (0,0051 – 0,788) mg w próbce\nStężenie/zawartość krzemionki krystalicznej (krystobalit)\nfrakcja respirabilna\nZakres (0,0076 – 5,54) mg/m3\nZakres (0,0052 – 0,758) mg w próbce\nMetoda spektrometrii w zakresie podczerwieni z transformacją Fouriera (FT-IR)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2012, nr 4 (74), str. 117-130","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2012, nr 4 (74), str. 117-130"],"lab_section":"Pracownia Zagrożeń Chemicznych i Pyłowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie/zawartość krzemionki krystalicznej (kwarc)\nZakres:\nfrakcja respirabilna\nZakres (0,0075 – 5,76) mg/m3\nZakres (0,0051 – 0,788) mg w próbce\nStężenie/zawartość krzemionki krystalicznej (krystobalit)\nfrakcja respirabilna\nZakres (0,0076 – 5,54) mg/m3\nZakres (0,0052 – 0,758) mg w próbce\nMetoda spektrometrii w zakresie podczerwieni z transformacją Fouriera (FT-IR) Podstawy i Metody Oceny Środowiska Pracy 2012, nr 4 (74), str. 117-130 Srodowisko pracy – powietrze Stezenie/zawartosc krzemionki krystalicznej (kwarc)\nZakres:\nfrakcja respirabilna\nZakres (0,0075 – 5,76) mg/m3\nZakres (0,0051 – 0,788) mg w probce\nStezenie/zawartosc krzemionki krystalicznej (krystobalit)\nfrakcja respirabilna\nZakres (0,0076 – 5,54) mg/m3\nZakres (0,0052 – 0,758) mg w probce\nMetoda spektrometrii w zakresie podczerwieni z transformacja Fouriera (FT-IR) Podstawy i Metody Oceny Srodowiska Pracy 2012, nr 4 (74), str. 117-130","categories":["environment"],"row_index":109,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"呼吸性组分"},{"name":"范围","range":"(0,0075 – 5,76) mg/m3"},{"name":"范围","range":"(0,0051 – 0,788) mg w próbce"},{"name":"Stężenie/zawartość krzemionki krystalicznej (krystobalit)"},{"name":"呼吸性组分"},{"name":"范围","range":"(0,0076 – 5,54) mg/m3"},{"name":"范围","range":"(0,0052 – 0,758) mg w próbce"}],"search_zh":"工作场所环境 — 空气 傅里叶变换红外光谱法（FT-IR） 呼吸性组分 范围 范围 呼吸性组分 范围 范围 Podstawy i Metody Oceny Środowiska Pracy 2012, nr 4 (74), str. 117-130","test_object_zh":"工作场所环境 — 空气","technique_zh":"傅里叶变换红外光谱法（FT-IR）"}],"has_pdf":true}