{"lab":{"_id":"69ad52a3de79e566650fb1c7","accr_number":"AB 336","country":"PL","accr_body":"PCA","address":"PAŃSTWOWY INSTYTUT BADAWCZY, ul. Słowicza 32, 02-170 Warszawa, LABORATORIUM FIZYKOCHEMICZNE, ul. ks. Zygmunta Trószyńskiego 9, 01-693 Warszawa","categories":["water","environment"],"city":"Warszawa","imported_at":"2026-03-08T10:42:43.265Z","methods_count":8,"name":"INSTYTUT OCHRONY ŚRODOWISKA –","parse_status":"parsed","parse_version":3,"pdf_files":["AB_336.pdf"],"scope_summary":"","search_text":"instytut ochrony środowiska – państwowy instytut badawczy, ul. słowicza 32, 02-170 warszawa, laboratorium fizykochemiczne, ul. ks. zygmunta trószyńskiego 9, 01-693 warszawa environment automotive water other pharma electronics","status":"active","updated_at":"2026-03-08T14:51:10.887Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-09-12T00:31:54.717Z","location":{"type":"Point","coordinates":[21.0122,52.2297]},"email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20336,podmiot.html","fields_of_testing":[{"codes":"C/9, C/28","pl":"Badania chemiczne powietrza, wody","en":"Chemical tests of air, water"},{"codes":"N/28","pl":"Badania właściwości fizycznych wody","en":"Tests of physical properties of water"}],"issue":{"no":"26","date":"10.09.2026"},"parse_date":"2026-09-12T00:31:54.717Z","parse_source":"agent-claude-code","map_coord":[52.188412,20.961555],"map_geo":"nominatim-street","has_en":true,"category_counts":{"water":5,"other":1,"environment":1},"category_scores":{"water":3.57,"other":0.14,"environment":0.14},"has_zh":true,"lab_locations":[{"code":null,"name":"INSTYTUT OCHRONY ŚRODOWISKA –","street":"ul. Słowicza 32","postal_code":"02-170","city":"Warszawa","is_hq":true,"address":"ul. Słowicza 32, 02-170 Warszawa","site":"02-170|słowicza32"},{"code":null,"name":"LABORATORIUM FIZYKOCHEMICZNE","street":"ul. ks. Zygmunta Trószyńskiego 9","postal_code":"01-693","city":"Warszawa","is_hq":false,"address":"ul. ks. Zygmunta Trószyńskiego 9, 01-693 Warszawa","site":"01-693|kszygmuntatrószyńskiego9"}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/9/11/674e965df4944c3df7b749ac30ee173e/AB%20336.pdf"},"methods":[{"_id":"6aa49d7a6bfbe5c0536296d8","lab_id":"69ad52a3de79e566650fb1c7","country":"PL","accr_number":"AB 336","accr_body":"PCA","test_object":"Środowisko ogólne – próbki powietrza atmosferycznego pobrane na filtry","methodology":"Zawartość azotu amonowego","parameters":[{"name":"Zakres","range":"(2,5 – 150) μg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość azotu amonowego\nZakres (2,5 – 150) μg w próbce\nMetoda spektrofotometryczna","reference":"Procedura badawcza BL-PB-21 wydanie 8 z dnia 20.04.2026 r.","norm_bases":["Procedura badawcza BL-PB-21 wydanie 8 z dnia 20.04.2026 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – próbki powietrza atmosferycznego pobrane na filtry Zawartość azotu amonowego\nZakres (2,5 – 150) μg w próbce\nMetoda spektrofotometryczna Procedura badawcza BL-PB-21 wydanie 8 z dnia 20.04.2026 r. Srodowisko ogolne – probki powietrza atmosferycznego pobrane na filtry Zawartosc azotu amonowego\nZakres (2,5 – 150) μg w probce\nMetoda spektrofotometryczna Procedura badawcza BL-PB-21 wydanie 8 z dnia 20.04.2026 r.","categories":["environment"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6aa49d7a6bfbe5c0536296d9","lab_id":"69ad52a3de79e566650fb1c7","country":"PL","accr_number":"AB 336","accr_body":"PCA","test_object":"Woda, opad atmosferyczny","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, opad atmosferyczny pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, opad atmosferyczny pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6aa49d7a6bfbe5c0536296da","lab_id":"69ad52a3de79e566650fb1c7","country":"PL","accr_number":"AB 336","accr_body":"PCA","test_object":"Woda, opad atmosferyczny","methodology":"Stężenie kationów","parameters":[{"name":"Ca2+","range":"(0,10 – 100) mg/l"},{"name":"K+","range":"(0,10 – 100) mg/l"},{"name":"Mg2+","range":"(0,10 – 100) mg/l"},{"name":"Na+","range":"(0,10 – 100) mg/l"},{"name":"NH4+","range":"(0,10 – 100) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie kationów\nZakres:\nCa2+ (0,10 – 100) mg/l\nK+ (0,10 – 100) mg/l\nMg2+ (0,10 – 100) mg/l\nNa+ (0,10 – 100) mg/l\nNH4+ (0,10 – 100) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 14911:2002","norm_bases":["PN-EN ISO 14911:2002"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, opad atmosferyczny Stężenie kationów\nZakres:\nCa2+ (0,10 – 100) mg/l\nK+ (0,10 – 100) mg/l\nMg2+ (0,10 – 100) mg/l\nNa+ (0,10 – 100) mg/l\nNH4+ (0,10 – 100) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 14911:2002 Woda, opad atmosferyczny Stezenie kationow\nZakres:\nCa2+ (0,10 – 100) mg/l\nK+ (0,10 – 100) mg/l\nMg2+ (0,10 – 100) mg/l\nNa+ (0,10 – 100) mg/l\nNH4+ (0,10 – 100) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 14911:2002","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6aa49d7a6bfbe5c0536296db","lab_id":"69ad52a3de79e566650fb1c7","country":"PL","accr_number":"AB 336","accr_body":"PCA","test_object":"Woda, opad atmosferyczny","methodology":"Stężenie anionów","parameters":[{"name":"Cl","range":"(0,10 – 100) mg/l"},{"name":"SO42","range":"(0,10 – 100) mg/l"},{"name":"NO3","range":"(0,10 – 100) mg/l"},{"name":"PO43","range":"(0,20 – 200) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie anionów\nZakres:\nCl (0,10 – 100) mg/l\nSO42 (0,10 – 100) mg/l\nNO3 (0,10 – 100) mg/l\nPO43 (0,20 – 200) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009","norm_bases":["PN-EN ISO 10304-1:2009"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, opad atmosferyczny Stężenie anionów\nZakres:\nCl (0,10 – 100) mg/l\nSO42 (0,10 – 100) mg/l\nNO3 (0,10 – 100) mg/l\nPO43 (0,20 – 200) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009 Woda, opad atmosferyczny Stezenie anionow\nZakres:\nCl (0,10 – 100) mg/l\nSO42 (0,10 – 100) mg/l\nNO3 (0,10 – 100) mg/l\nPO43 (0,20 – 200) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009","categories":["water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6aa49d7a6bfbe5c0536296dc","lab_id":"69ad52a3de79e566650fb1c7","country":"PL","accr_number":"AB 336","accr_body":"PCA","test_object":"Woda, opad atmosferyczny","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,05 – 15,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,05 – 15,0) mg/l\nMetoda spektrofotometryczna","reference":"Procedura badawcza BL-PB-21 wydanie 8 z dnia 20.04.2026 r.","norm_bases":["Procedura badawcza BL-PB-21 wydanie 8 z dnia 20.04.2026 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, opad atmosferyczny Stężenie azotu amonowego\nZakres (0,05 – 15,0) mg/l\nMetoda spektrofotometryczna Procedura badawcza BL-PB-21 wydanie 8 z dnia 20.04.2026 r. Woda, opad atmosferyczny Stezenie azotu amonowego\nZakres (0,05 – 15,0) mg/l\nMetoda spektrofotometryczna Procedura badawcza BL-PB-21 wydanie 8 z dnia 20.04.2026 r.","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6aa49d7a6bfbe5c0536296dd","lab_id":"69ad52a3de79e566650fb1c7","country":"PL","accr_number":"AB 336","accr_body":"PCA","test_object":"Woda, opad atmosferyczny","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(10 – 1410) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (10 – 1410) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, opad atmosferyczny Przewodność elektryczna właściwa\nZakres (10 – 1410) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, opad atmosferyczny Przewodnosc elektryczna wlasciwa\nZakres (10 – 1410) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6aa49d7a6bfbe5c0536296de","lab_id":"69ad52a3de79e566650fb1c7","country":"PL","accr_number":"AB 336","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie pierwiastków","parameters":[{"name":"Al","range":"(0,014 – 10) mg/l"},{"name":"Ca","range":"(2,25 – 250) mg/l"},{"name":"Fe","range":"(0,09 – 10) mg/l"},{"name":"K","range":"(0,27 – 30) mg/l"},{"name":"Mg","range":"(0,27 – 30) mg/l"},{"name":"Mn","range":"(0,018 – 2,0) mg/l"},{"name":"Na","range":"(0,36 – 40) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie pierwiastków\nZakres:\nAl (0,014 – 10) mg/l\nCa (2,25 – 250) mg/l\nFe (0,09 – 10) mg/l\nK (0,27 – 30) mg/l\nMg (0,27 – 30) mg/l\nMn (0,018 – 2,0) mg/l\nNa (0,36 – 40) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"Procedura badawcza BL-PB-10 wydanie 14 z dnia 04.07.2025 r.","norm_bases":["Procedura badawcza BL-PB-10 wydanie 14 z dnia 04.07.2025 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie pierwiastków\nZakres:\nAl (0,014 – 10) mg/l\nCa (2,25 – 250) mg/l\nFe (0,09 – 10) mg/l\nK (0,27 – 30) mg/l\nMg (0,27 – 30) mg/l\nMn (0,018 – 2,0) mg/l\nNa (0,36 – 40) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) Procedura badawcza BL-PB-10 wydanie 14 z dnia 04.07.2025 r. Woda Stezenie pierwiastkow\nZakres:\nAl (0,014 – 10) mg/l\nCa (2,25 – 250) mg/l\nFe (0,09 – 10) mg/l\nK (0,27 – 30) mg/l\nMg (0,27 – 30) mg/l\nMn (0,018 – 2,0) mg/l\nNa (0,36 – 40) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) Procedura badawcza BL-PB-10 wydanie 14 z dnia 04.07.2025 r.","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6aa49d7a6bfbe5c0536296df","lab_id":"69ad52a3de79e566650fb1c7","country":"PL","accr_number":"AB 336","accr_body":"PCA","test_object":"Opad atmosferyczny","methodology":"Stężenie pierwiastków","parameters":[{"name":"Al","range":"(0,014 – 1,5) mg/l"},{"name":"Ca","range":"(0,23 – 25) mg/l"},{"name":"Fe","range":"(0,023 – 2,0) mg/l"},{"name":"K","range":"(0,23 – 25) mg/l"},{"name":"Mg","range":"(0,054 – 6,0) mg/l"},{"name":"Mn","range":"(0,027 – 3,0) mg/l"},{"name":"Na","range":"(0,091 – 10) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie pierwiastków\nZakres:\nAl (0,014 – 1,5) mg/l\nCa (0,23 – 25) mg/l\nFe (0,023 – 2,0) mg/l\nK (0,23 – 25) mg/l\nMg (0,054 – 6,0) mg/l\nMn (0,027 – 3,0) mg/l\nNa (0,091 – 10) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"Procedura badawcza BL-PB-10 wydanie 14 z dnia 04.07.2025 r.","norm_bases":["Procedura badawcza BL-PB-10 wydanie 14 z dnia 04.07.2025 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Opad atmosferyczny Stężenie pierwiastków\nZakres:\nAl (0,014 – 1,5) mg/l\nCa (0,23 – 25) mg/l\nFe (0,023 – 2,0) mg/l\nK (0,23 – 25) mg/l\nMg (0,054 – 6,0) mg/l\nMn (0,027 – 3,0) mg/l\nNa (0,091 – 10) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) Procedura badawcza BL-PB-10 wydanie 14 z dnia 04.07.2025 r. Opad atmosferyczny Stezenie pierwiastkow\nZakres:\nAl (0,014 – 1,5) mg/l\nCa (0,23 – 25) mg/l\nFe (0,023 – 2,0) mg/l\nK (0,23 – 25) mg/l\nMg (0,054 – 6,0) mg/l\nMn (0,027 – 3,0) mg/l\nNa (0,091 – 10) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) Procedura badawcza BL-PB-10 wydanie 14 z dnia 04.07.2025 r.","categories":["other"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code"}],"has_pdf":true}