{"lab":{"_id":"69ad52a3de79e566650fb1bf","accr_number":"AB 325","country":"PL","accr_body":"PCA","address":"CENTRALNE LABORATORIUM, ul. Kossutha 6, 40-844 Katowice","categories":["environment","water","petro","materials"],"city":"Katowice","imported_at":"2026-03-08T10:42:43.265Z","methods_count":60,"name":"INSTYTUT EKOLOGII TERENÓW UPRZEMYSŁOWIONYCH","parse_status":"parsed","parse_version":3,"pdf_files":["AB_325.pdf"],"scope_summary":"","search_text":"instytut ekologii terenów uprzemysłowionych centralne laboratorium, ul. kossutha 6, 40-844 katowice water other pharma electronics materials environment food petro metrology","status":"active","updated_at":"2026-03-08T14:51:10.539Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:10.539Z","location":{"type":"Point","coordinates":[19.0238,50.2649]},"email_confidence":"high","email_mx":true,"email_source":"https://bip.ietu.pl/","fields_of_testing":[{"codes":"C/28/P, C/30/P, C/31/P, C/32","pl":"Badania chemiczne i pobieranie próbek wody, gleby, odpadów, ścieków","en":"Chemical tests and sampling od water, soil, waste, sewage"},{"codes":"C/10","pl":"Badania chemiczne paliw stałych","en":"Chemical tests of solid fuels"},{"codes":"G/34","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko ogólne (czynniki fizyczne – hałas","en":"Tests concerning environmental engineering (environmental and climatic) –general environment (physical factors – noise),"},{"codes":"N/28/P, N/30/P, N/31/P, N/32/P","pl":"Badania właściwości fizycznych i pobierania próbek wody, gleby, odpadów, ścieków","en":"Tests of physical properties and sampling of water, soil, waste, sewage"},{"codes":"N/10","pl":"Badania właściwości fizycznych paliw stałych","en":"Tests of physical properties of solid fuels"}],"issue":{"no":"25","date":"13.02.2026"},"parse_date":"2026-07-20T07:09:33.947Z","parse_source":"script-pdfplumber","map_coord":[50.264703,18.975605],"map_geo":"nominatim-street","has_en":true,"category_counts":{"environment":31,"water":22,"petro":9,"materials":6,"metrology":1},"category_scores":{"environment":13.93,"water":7.01,"petro":1.17,"materials":0.52,"metrology":0.01},"has_zh":true},"methods":[{"_id":"6a5dc9adf1c10c8ce825acdf","lab_id":"69ad52a3de79e566650fb1bf","country":"PL","accr_number":"AB 325","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-4:2017-10 | PN-EN ISO 5667-6:2016-12 | PN-ISO 5667-11:2017-10","norm_bases":["PN-ISO 5667-4:2017-10","PN-EN ISO 5667-6:2016-12","PN-ISO 5667-11:2017-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-4:2017-10 | PN-EN ISO 5667-6:2016-12 | PN-ISO 5667-11:2017-10 Woda Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-4:2017-10 | PN-EN ISO 5667-6:2016-12 | PN-ISO 5667-11:2017-10","categories":["water"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Sampling for chemical and physical testing PN-ISO 5667-4:2017-10 | PN-EN ISO 5667-6:2016-12 | PN-ISO 5667-11:2017-10","methodology_zh":"化学与物理检测用样品采集","search_zh":"水 化学与物理检测用样品采集 PN-ISO 5667-4:2017-10 | PN-EN ISO 5667-6:2016-12 | PN-ISO 5667-11:2017-10","test_object_zh":"水"},{"_id":"6a5dc9adf1c10c8ce825ace0","lab_id":"69ad52a3de79e566650fb1bf","country":"PL","accr_number":"AB 325","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Całkowite substancje rozpuszczone (TDS)","methodology_en":"Total dissolved solids (TDS)","parameters":[{"name":"Zakres","range":"(10 – 100 000) mg/l"}],"parameters_en":[{"name":"Range","range":"(10 – 100 000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Całkowite substancje rozpuszczone (TDS)\nZakres (10 – 100 000) mg/l\nMetoda wagowa","reference":"PN-EN 15216:2022-03","norm_bases":["PN-EN 15216:2022-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Całkowite substancje rozpuszczone (TDS)\nZakres (10 – 100 000) mg/l\nMetoda wagowa PN-EN 15216:2022-03 Woda Calkowite substancje rozpuszczone (TDS)\nZakres (10 – 100 000) mg/l\nMetoda wagowa PN-EN 15216:2022-03","categories":["water"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Total dissolved solids (TDS) Gravimetric method Range PN-EN 15216:2022-03","parameters_zh":[{"name":"范围","range":"(10 – 100 000) mg/l"}],"search_zh":"水 溶解性总固体（TDS） 重量法 范围 PN-EN 15216:2022-03","technique_zh":"重量法","test_object_zh":"水","methodology_zh":"溶解性总固体（TDS）"},{"_id":"6a5dc9adf1c10c8ce825ace1","lab_id":"69ad52a3de79e566650fb1bf","country":"PL","accr_number":"AB 325","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":"Metoda manualna","techniques":["Metoda manualna"],"technique_en":"Manual method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna PN-ISO 5667-10:2021-11 Scieki Pobieranie probek do badan chemicznych i fizycznych\nMetoda manualna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Sampling for chemical and physical testing Manual method PN-ISO 5667-10:2021-11","methodology_zh":"化学与物理检测用样品采集","search_zh":"污水 化学与物理检测用样品采集 手工法 PN-ISO 5667-10:2021-11","test_object_zh":"污水","technique_zh":"手工法"},{"_id":"6a5dc9adf1c10c8ce825ace2","lab_id":"69ad52a3de79e566650fb1bf","country":"PL","accr_number":"AB 325","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)","methodology_en":"Total content of calcium and magnesium (total hardness)","parameters":[{"name":"Zakres","range":"(0,05 – 50) mmol/l"},{"name":"Zakres","range":"(5,0 – 5000) mg /l CaCO3"}],"parameters_en":[{"name":"Range","range":"(0,05 – 50) mmol/l"},{"name":"Range","range":"(5,0 – 5000) mg /l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres:\nZakres (0,05 – 50) mmol/l\nZakres (5,0 – 5000) mg /l CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres:\nZakres (0,05 – 50) mmol/l\nZakres (5,0 – 5000) mg /l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999 Woda, Scieki Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna)\nZakres:\nZakres (0,05 – 50) mmol/l\nZakres (5,0 – 5000) mg /l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Total content of calcium and magnesium (total hardness) Titrimetric method Range Range PN-ISO 6059:1999","methodology_zh":"钙与镁总量（总硬度）","parameters_zh":[{"name":"范围","range":"(0,05 – 50) mmol/l"},{"name":"范围","range":"(5,0 – 5000) mg /l CaCO3"}],"search_zh":"水、污水 钙与镁总量（总硬度） 滴定法 范围 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"水、污水"},{"_id":"6a5dc9adf1c10c8ce825ace3","lab_id":"69ad52a3de79e566650fb1bf","country":"PL","accr_number":"AB 325","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, Scieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"水、污水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、污水"},{"_id":"6a5dc9adf1c10c8ce825ace4","lab_id":"69ad52a3de79e566650fb1bf","country":"PL","accr_number":"AB 325","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Przewodność elektryczna właściwa","methodology_en":"Electrical conductivity","parameters":[{"name":"Zakres","range":"(10 – 25000) μS/cm"}],"parameters_en":[{"name":"Range","range":"(10 – 25000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"technique_en":"Conductometric method","computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa\nZakres (10 – 25000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Przewodność elektryczna właściwa\nZakres (10 – 25000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, Scieki Przewodnosc elektryczna wlasciwa\nZakres (10 – 25000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Electrical conductivity Conductometric method Range PN-EN 27888:1999","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(10 – 25000) μS/cm"}],"search_zh":"水、污水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、污水"},{"_id":"6a5dc9adf1c10c8ce825ace5","lab_id":"69ad52a3de79e566650fb1bf","country":"PL","accr_number":"AB 325","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Chemiczne zapotrzebowania tlenu -ChZT- Cr","methodology_en":"Chemical oxygen demand -COD- Cr","parameters":[{"name":"Zakres","range":"(15,0 – 1500) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(15,0 – 1500) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowania tlenu -ChZT- Cr\nZakres (15,0 – 1500) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Chemiczne zapotrzebowania tlenu -ChZT- Cr\nZakres (15,0 – 1500) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda, Scieki Chemiczne zapotrzebowania tlenu -ChZT- Cr\nZakres (15,0 – 1500) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Chemical oxygen demand -COD- Cr Spectrophotometric method Range PN-ISO 15705:2005","parameters_zh":[{"name":"范围","range":"(15,0 – 1500) mg/l O2"}],"search_zh":"水、污水 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a5dc9adf1c10c8ce825ace6","lab_id":"69ad52a3de79e566650fb1bf","country":"PL","accr_number":"AB 325","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie chlorków","methodology_en":"Chloride concentration","parameters":[{"name":"Zakres","range":"(5,0 – 10 000) mg/l"}],"parameters_en":[{"name":"Range","range":"(5,0 – 10 000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie chlorków\nZakres (5,0 – 10 000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie chlorków\nZakres (5,0 – 10 000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda, Scieki Stezenie chlorkow\nZakres (5,0 – 10 000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Chloride concentration Titrimetric method Range PN-ISO 9297:1994","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,0 – 10 000) mg/l"}],"search_zh":"水、污水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水、污水"},{"_id":"6a5dc9adf1c10c8ce825ace7","lab_id":"69ad52a3de79e566650fb1bf","country":"PL","accr_number":"AB 325","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie siarczanów (VI)","methodology_en":"Sulphate (VI) concentration","parameters":[{"name":"Zakres","range":"(10,0 – 10 000) mg/l"}],"parameters_en":[{"name":"Range","range":"(10,0 – 10 000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie siarczanów (VI)\nZakres (10,0 – 10 000) mg/l\nMetoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie siarczanów (VI)\nZakres (10,0 – 10 000) mg/l\nMetoda wagowa PN-ISO 9280:2002 Woda, Scieki Stezenie siarczanow (VI)\nZakres (10,0 – 10 000) mg/l\nMetoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Sulphate (VI) concentration Gravimetric method Range PN-ISO 9280:2002","parameters_zh":[{"name":"范围","range":"(10,0 – 10 000) mg/l"}],"search_zh":"水、污水 硫酸盐(VI)浓度 重量法 范围 PN-ISO 9280:2002","technique_zh":"重量法","test_object_zh":"水、污水","methodology_zh":"硫酸盐(VI)浓度"},{"_id":"6a5dc9adf1c10c8ce825ace8","lab_id":"69ad52a3de79e566650fb1bf","country":"PL","accr_number":"AB 325","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie ortofosforanów","methodology_en":"Orthophosphate concentration","parameters":[{"name":"Zakres","range":"(0,050 – 100)mg/l"}],"parameters_en":[{"name":"Range","range":"(0,050 – 100)mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie ortofosforanów\nZakres (0,050 – 100)mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 p.4 +Ap1:2010 +Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 p.4 +Ap1:2010 +Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie ortofosforanów\nZakres (0,050 – 100)mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 p.4 +Ap1:2010 +Ap2:2010 Woda, Scieki Stezenie ortofosforanow\nZakres (0,050 – 100)mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 p.4 +Ap1:2010 +Ap2:2010","categories":["water"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Orthophosphate concentration Spectrophotometric method Range PN-EN ISO 6878:2006 p.4 +Ap1:2010 +Ap2:2010","parameters_zh":[{"name":"范围","range":"(0,050 – 100)mg/l"}],"search_zh":"水、污水 正磷酸盐浓度 分光光度法 范围 PN-EN ISO 6878:2006 p.4 +Ap1:2010 +Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水、污水","methodology_zh":"正磷酸盐浓度"},{"_id":"6a5dc9adf1c10c8ce825ace9","lab_id":"69ad52a3de79e566650fb1bf","country":"PL","accr_number":"AB 325","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie azotu azotanowego","methodology_en":"Nitrate nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,05 – 50) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,05 – 50) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu azotanowego\nZakres (0,05 – 50) mg/l\nMetoda spektrofotometryczna","reference":"PB-15, wydanie 4 z dnia 30.05.2018 r.","norm_bases":["PB-15, wydanie 4 z dnia 30.05.2018 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie azotu azotanowego\nZakres (0,05 – 50) mg/l\nMetoda spektrofotometryczna PB-15, wydanie 4 z dnia 30.05.2018 r. Woda, Scieki Stezenie azotu azotanowego\nZakres (0,05 – 50) mg/l\nMetoda spektrofotometryczna PB-15, wydanie 4 z dnia 30.05.2018 r.","categories":["water"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Nitrate nitrogen concentration Spectrophotometric method Range PB-15, wydanie 4 z dnia 30.05.2018 r.","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,05 – 50) mg/l"}],"search_zh":"水、污水 硝态氮浓度 分光光度法 范围 PB-15, wydanie 4 z dnia 30.05.2018 r.","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a5dc9adf1c10c8ce825acea","lab_id":"69ad52a3de79e566650fb1bf","country":"PL","accr_number":"AB 325","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie azotu azotynowego","methodology_en":"Nitrite nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,008 – 3,2) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,008 – 3,2) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu azotynowego\nZakres (0,008 – 3,2) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie azotu azotynowego\nZakres (0,008 – 3,2) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, Scieki Stezenie azotu azotynowego\nZakres (0,008 – 3,2) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Nitrite nitrogen concentration Spectrophotometric method Range PN-EN 26777:1999","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,008 – 3,2) mg/l"}],"search_zh":"水、污水 亚硝态氮浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a5dc9adf1c10c8ce825aceb","lab_id":"69ad52a3de79e566650fb1bf","country":"PL","accr_number":"AB 325","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie metali","methodology_en":"Metal concentrations","parameters":[{"name":"potas","range":"(0,10 – 2000) mg/l"}],"parameters_en":[{"name":"potassium","range":"(0,10 – 2000) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"technique_en":"Flame atomic absorption spectrometry (FAAS)","computed":[],"computed_en":[],"activity":"Stężenie metali\npotas (0,10 – 2000) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PB-05/1, wydanie 5 z dnia 30.08.2017 r.","norm_bases":["PB-05/1, wydanie 5 z dnia 30.08.2017 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie metali\npotas (0,10 – 2000) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB-05/1, wydanie 5 z dnia 30.08.2017 r. Woda, Scieki Stezenie metali\npotas (0,10 – 2000) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB-05/1, wydanie 5 z dnia 30.08.2017 r.","categories":["water","materials"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Metal concentrations Flame atomic absorption spectrometry (FAAS) potassium PB-05/1, wydanie 5 z dnia 30.08.2017 r.","methodology_zh":"金属浓度","search_zh":"水、污水 金属浓度 火焰原子吸收光谱法（FAAS） 钾 PB-05/1, wydanie 5 z dnia 30.08.2017 r.","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"水、污水","parameters_zh":[{"name":"钾","range":"(0,10 – 2000) mg/l"}]},{"_id":"6a5dc9adf1c10c8ce825acec","lab_id":"69ad52a3de79e566650fb1bf","country":"PL","accr_number":"AB 325","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie rtęci","methodology_en":"Mercury concentration","parameters":[{"name":"Zakres","range":"(0,015 – 20 ) μg/l"}],"parameters_en":[{"name":"Range","range":"(0,015 – 20 ) μg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)"],"technique_en":"Cold vapour atomic absorption spectrometry (CVAAS)","computed":[],"computed_en":[],"activity":"Stężenie rtęci\nZakres (0,015 – 20 ) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"PN-EN ISO 12846:2012/Ap1:2016-07","norm_bases":["PN-EN ISO 12846:2012/Ap1:2016-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie rtęci\nZakres (0,015 – 20 ) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN ISO 12846:2012/Ap1:2016-07 Woda, Scieki Stezenie rteci\nZakres (0,015 – 20 ) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN ISO 12846:2012/Ap1:2016-07","categories":["water"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Mercury concentration Cold vapour atomic absorption spectrometry (CVAAS) Range PN-EN ISO 12846:2012/Ap1:2016-07","methodology_zh":"汞浓度","parameters_zh":[{"name":"范围","range":"(0,015 – 20 ) μg/l"}],"search_zh":"水、污水 汞浓度 冷蒸气原子吸收光谱法（CVAAS） 范围 PN-EN ISO 12846:2012/Ap1:2016-07","technique_zh":"冷蒸气原子吸收光谱法（CVAAS）","test_object_zh":"水、污水"},{"_id":"6a5dc9adf1c10c8ce825aced","lab_id":"69ad52a3de79e566650fb1bf","country":"PL","accr_number":"AB 325","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie arsenu","methodology_en":"Arsenic concentration","parameters":[{"name":"Zakres","range":"(0,5 – 40) μg/l"}],"parameters_en":[{"name":"Range","range":"(0,5 – 40) μg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem wodorków (HGAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem wodorków (HGAAS)"],"technique_en":"Hydride generation atomic absorption spectrometry (HGAAS)","computed":[],"computed_en":[],"activity":"Stężenie arsenu\nZakres (0,5 – 40) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem wodorków (HGAAS)","reference":"PB-05/4, wydanie 5 z dnia 30.08.2017 r.","norm_bases":["PB-05/4, wydanie 5 z dnia 30.08.2017 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie arsenu\nZakres (0,5 – 40) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem wodorków (HGAAS) PB-05/4, wydanie 5 z dnia 30.08.2017 r. Woda, Scieki Stezenie arsenu\nZakres (0,5 – 40) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem wodorkow (HGAAS) PB-05/4, wydanie 5 z dnia 30.08.2017 r.","categories":["water"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Arsenic concentration Hydride generation atomic absorption spectrometry (HGAAS) Range PB-05/4, wydanie 5 z dnia 30.08.2017 r.","parameters_zh":[{"name":"范围","range":"(0,5 – 40) μg/l"}],"search_zh":"水、污水 砷浓度 氢化物发生原子吸收光谱法（HGAAS） 范围 PB-05/4, wydanie 5 z dnia 30.08.2017 r.","test_object_zh":"水、污水","technique_zh":"氢化物发生原子吸收光谱法（HGAAS）","methodology_zh":"砷浓度"},{"_id":"6a5dc9adf1c10c8ce825acee","lab_id":"69ad52a3de79e566650fb1bf","country":"PL","accr_number":"AB 325","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie metali","methodology_en":"Metal concentrations","parameters":[{"name":"kadm","range":"(0,20 – 40) μg/l"},{"name":"ołów","range":"(2,0 – 200) μg/l"},{"name":"arsen","range":"(5,0 – 20) μg/l"},{"name":"selen","range":"(5,0 – 25) μg/l"},{"name":"antymon","range":"(5,0 – 25) μg/l"}],"parameters_en":[{"name":"cadmium","range":"(0,20 – 40) μg/l"},{"name":"lead","range":"(2,0 – 200) μg/l"},{"name":"arsenic","range":"(5,0 – 20) μg/l"},{"name":"selenium","range":"(5,0 – 25) μg/l"},{"name":"antimony","range":"(5,0 – 25) μg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)"],"technique_en":"Electrothermal atomization atomic absorption spectrometry (ETAAS)","computed":[],"computed_en":[],"activity":"Stężenie metali\nZakres:\nkadm (0,20 – 40) μg/l\nołów (2,0 – 200) μg/l\narsen (5,0 – 20) μg/l\nselen (5,0 – 25) μg/l\nantymon (5,0 – 25) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","reference":"PB-05/5, wydanie 3 z dnia 30.08.2017 r.","norm_bases":["PB-05/5, wydanie 3 z dnia 30.08.2017 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie metali\nZakres:\nkadm (0,20 – 40) μg/l\nołów (2,0 – 200) μg/l\narsen (5,0 – 20) μg/l\nselen (5,0 – 25) μg/l\nantymon (5,0 – 25) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS) PB-05/5, wydanie 3 z dnia 30.08.2017 r. Woda, Scieki Stezenie metali\nZakres:\nkadm (0,20 – 40) μg/l\nolow (2,0 – 200) μg/l\narsen (5,0 – 20) μg/l\nselen (5,0 – 25) μg/l\nantymon (5,0 – 25) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacja elektrotermiczna (ETAAS) PB-05/5, wydanie 3 z dnia 30.08.2017 r.","categories":["water","materials"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Metal concentrations Electrothermal atomization atomic absorption spectrometry (ETAAS) cadmium lead arsenic selenium antimony PB-05/5, wydanie 3 z dnia 30.08.2017 r.","methodology_zh":"金属浓度","parameters_zh":[{"name":"镉","range":"(0,20 – 40) μg/l"},{"name":"铅","range":"(2,0 – 200) μg/l"},{"name":"砷","range":"(5,0 – 20) μg/l"},{"name":"硒","range":"(5,0 – 25) μg/l"},{"name":"锑","range":"(5,0 – 25) μg/l"}],"search_zh":"水、污水 金属浓度 电热原子化原子吸收光谱法（ETAAS） 镉 铅 砷 硒 锑 PB-05/5, wydanie 3 z dnia 30.08.2017 r.","technique_zh":"电热原子化原子吸收光谱法（ETAAS）","test_object_zh":"水、污水"},{"_id":"6a5dc9adf1c10c8ce825acef","lab_id":"69ad52a3de79e566650fb1bf","country":"PL","accr_number":"AB 325","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie ogólnego węgla organicznego (OWO)","methodology_en":"Total organic carbon concentration (TOC)","parameters":[{"name":"Zakres","range":"(1,0 – 1000) mg/l"}],"parameters_en":[{"name":"Range","range":"(1,0 – 1000) mg/l"}],"technique":"Metoda spektrometrii w podczerwieni (IR)","techniques":["Metoda spektrometrii w podczerwieni (IR)"],"technique_en":"Infrared spectrometry method (IR)","computed":[],"computed_en":[],"activity":"Stężenie ogólnego węgla organicznego (OWO)\nZakres (1,0 – 1000) mg/l\nMetoda spektrometrii w podczerwieni (IR)","reference":"PN-EN 1484:1999","norm_bases":["PN-EN 1484:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie ogólnego węgla organicznego (OWO)\nZakres (1,0 – 1000) mg/l\nMetoda spektrometrii w podczerwieni (IR) PN-EN 1484:1999 Woda, Scieki Stezenie ogolnego wegla organicznego (OWO)\nZakres (1,0 – 1000) mg/l\nMetoda spektrometrii w podczerwieni (IR) PN-EN 1484:1999","categories":["water"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Total organic carbon concentration (TOC) Infrared spectrometry method (IR) Range PN-EN 1484:1999","parameters_zh":[{"name":"范围","range":"(1,0 – 1000) mg/l"}],"search_zh":"水、污水 总有机碳浓度（TOC） 红外光谱法（IR） 范围 PN-EN 1484:1999","test_object_zh":"水、污水","methodology_zh":"总有机碳浓度（TOC）","technique_zh":"红外光谱法（IR）"},{"_id":"6a5dc9adf1c10c8ce825acf0","lab_id":"69ad52a3de79e566650fb1bf","country":"PL","accr_number":"AB 325","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie azotu amonowego","methodology_en":"Ammonium nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,25 – 50) mg /l"}],"parameters_en":[{"name":"Range","range":"(0,25 – 50) mg /l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego\nZakres (0,25 – 50) mg /l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie azotu amonowego\nZakres (0,25 – 50) mg /l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, Scieki Stezenie azotu amonowego\nZakres (0,25 – 50) mg /l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Ammonium nitrogen concentration Spectrophotometric method Range PN-ISO 7150-1:2002","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,25 – 50) mg /l"}],"search_zh":"水、污水 氨氮浓度 分光光度法 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a5dc9adf1c10c8ce825acf1","lab_id":"69ad52a3de79e566650fb1bf","country":"PL","accr_number":"AB 325","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie pierwiastków","methodology_en":"Element concentration","parameters":[{"name":"wapń","range":"(0,500 – 5000) mg/l"},{"name":"magnez","range":"(0,100 – 1000) mg/l"},{"name":"sód","range":"(1,00 – 2000) mg/l"},{"name":"żelazo","range":"(0,020 – 100) mg/l"},{"name":"mangan","range":"(0,010 – 100) mg/l"},{"name":"cynk","range":"(0,005 – 100) mg/l"},{"name":"kadm","range":"(0,003 – 0,50) mg/l"},{"name":"ołów","range":"(0,015 – 0,50) mg/l"},{"name":"chrom","range":"(0,010 – 10,0) mg/l"},{"name":"miedź","range":"(0,010 – 10,0) mg/l"},{"name":"nikiel","range":"(0,010 – 10,0) mg/l"},{"name":"kobalt","range":"(0,020 – 10,0) mg/l"},{"name":"bar","range":"(0,100 – 100) mg/l"},{"name":"bor","range":"(0,100 – 100) mg/l"},{"name":"stront","range":"(0,100 – 10) mg/l"},{"name":"molibden","range":"(0,100 – 10,0) mg/l"}],"parameters_en":[{"name":"calcium","range":"(0,500 – 5000) mg/l"},{"name":"magnesium","range":"(0,100 – 1000) mg/l"},{"name":"sodium","range":"(1,00 – 2000) mg/l"},{"name":"iron","range":"(0,020 – 100) mg/l"},{"name":"manganese","range":"(0,010 – 100) mg/l"},{"name":"zinc","range":"(0,005 – 100) mg/l"},{"name":"cadmium","range":"(0,003 – 0,50) mg/l"},{"name":"lead","range":"(0,015 – 0,50) mg/l"},{"name":"chromium","range":"(0,010 – 10,0) mg/l"},{"name":"copper","range":"(0,010 – 10,0) mg/l"},{"name":"nickel","range":"(0,010 – 10,0) mg/l"},{"name":"cobalt","range":"(0,020 – 10,0) mg/l"},{"name":"barium","range":"(0,100 – 100) mg/l"},{"name":"boron","range":"(0,100 – 100) mg/l"},{"name":"strontium","range":"(0,100 – 10) mg/l"},{"name":"molybdenum","range":"(0,100 – 10,0) mg/l"}],"technique":"Metoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","computed":[],"computed_en":[],"activity":"Stężenie pierwiastków\nZakres:\nwapń (0,500 – 5000) mg/l\nmagnez (0,100 – 1000) mg/l\nsód (1,00 – 2000) mg/l\nżelazo (0,020 – 100) mg/l\nmangan (0,010 – 100) mg/l\ncynk (0,005 – 100) mg/l\nkadm (0,003 – 0,50) mg/l\nołów (0,015 – 0,50) mg/l\nchrom (0,010 – 10,0) mg/l\nmiedź (0,010 – 10,0) mg/l\nnikiel (0,010 – 10,0) mg/l\nkobalt (0,020 – 10,0) mg/l\nbar (0,100 – 100) mg/l\nbor (0,100 – 100) mg/l\nstront (0,100 – 10) mg/l\nmolibden (0,100 – 10,0) mg/l\nMetoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie pierwiastków\nZakres:\nwapń (0,500 – 5000) mg/l\nmagnez (0,100 – 1000) mg/l\nsód (1,00 – 2000) mg/l\nżelazo (0,020 – 100) mg/l\nmangan (0,010 – 100) mg/l\ncynk (0,005 – 100) mg/l\nkadm (0,003 – 0,50) mg/l\nołów (0,015 – 0,50) mg/l\nchrom (0,010 – 10,0) mg/l\nmiedź (0,010 – 10,0) mg/l\nnikiel (0,010 – 10,0) mg/l\nkobalt (0,020 – 10,0) mg/l\nbar (0,100 – 100) mg/l\nbor (0,100 – 100) mg/l\nstront (0,100 – 10) mg/l\nmolibden (0,100 – 10,0) mg/l\nMetoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Woda, Scieki Stezenie pierwiastkow\nZakres:\nwapn (0,500 – 5000) mg/l\nmagnez (0,100 – 1000) mg/l\nsod (1,00 – 2000) mg/l\nzelazo (0,020 – 100) mg/l\nmangan (0,010 – 100) mg/l\ncynk (0,005 – 100) mg/l\nkadm (0,003 – 0,50) mg/l\nolow (0,015 – 0,50) mg/l\nchrom (0,010 – 10,0) mg/l\nmiedz (0,010 – 10,0) mg/l\nnikiel (0,010 – 10,0) mg/l\nkobalt (0,020 – 10,0) mg/l\nbar (0,100 – 100) mg/l\nbor (0,100 – 100) mg/l\nstront (0,100 – 10) mg/l\nmolibden (0,100 – 10,0) mg/l\nMetoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["water","materials"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Element concentration Inductively coupled plasma optical emission spectrometry (ICP-OES) calcium magnesium sodium iron manganese zinc cadmium lead chromium copper nickel cobalt barium boron strontium molybdenum PN-EN ISO 11885:2009","methodology_zh":"元素浓度","parameters_zh":[{"name":"钙","range":"(0,500 – 5000) mg/l"},{"name":"镁","range":"(0,100 – 1000) mg/l"},{"name":"钠","range":"(1,00 – 2000) mg/l"},{"name":"铁","range":"(0,020 – 100) mg/l"},{"name":"锰","range":"(0,010 – 100) mg/l"},{"name":"锌","range":"(0,005 – 100) mg/l"},{"name":"镉","range":"(0,003 – 0,50) mg/l"},{"name":"铅","range":"(0,015 – 0,50) mg/l"},{"name":"铬","range":"(0,010 – 10,0) mg/l"},{"name":"铜","range":"(0,010 – 10,0) mg/l"},{"name":"镍","range":"(0,010 – 10,0) mg/l"},{"name":"钴","range":"(0,020 – 10,0) mg/l"},{"name":"钡","range":"(0,100 – 100) mg/l"},{"name":"硼","range":"(0,100 – 100) mg/l"},{"name":"锶","range":"(0,100 – 10) mg/l"},{"name":"钼","range":"(0,100 – 10,0) mg/l"}],"search_zh":"水、污水 元素浓度 电感耦合等离子体发射光谱法（ICP-OES） 钙 镁 钠 铁 锰 锌 镉 铅 铬 铜 镍 钴 钡 硼 锶 钼 PN-EN ISO 11885:2009","test_object_zh":"水、污水","technique_zh":"电感耦合等离子体发射光谱法（ICP-OES）"},{"_id":"6a5dc9adf1c10c8ce825acf2","lab_id":"69ad52a3de79e566650fb1bf","country":"PL","accr_number":"AB 325","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Zawiesiny ogólne","methodology_en":"Total suspended solids (TSS)","parameters":[{"name":"Zakres","range":"(5,0 – 6000) mg/l"}],"parameters_en":[{"name":"Range","range":"(5,0 – 6000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawiesiny ogólne\nZakres (5,0 – 6000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap.1:2007","norm_bases":["PN-EN 872:2007+Ap.1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Zawiesiny ogólne\nZakres (5,0 – 6000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap.1:2007 Woda, Scieki Zawiesiny ogolne\nZakres (5,0 – 6000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap.1:2007","categories":["water"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap.1:2007","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(5,0 – 6000) mg/l"}],"search_zh":"水、污水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap.1:2007","technique_zh":"重量法","test_object_zh":"水、污水"},{"_id":"6a5dc9adf1c10c8ce825acf3","lab_id":"69ad52a3de79e566650fb1bf","country":"PL","accr_number":"AB 325","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 10381-5:2009","norm_bases":["PN-ISO 10381-5:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 10381-5:2009 Gleba Pobieranie probek do badan chemicznych i fizycznych PN-ISO 10381-5:2009","categories":["environment"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Soil Sampling for chemical and physical testing PN-ISO 10381-5:2009","methodology_zh":"化学与物理检测用样品采集","search_zh":"土壤 化学与物理检测用样品采集 PN-ISO 10381-5:2009","test_object_zh":"土壤"},{"_id":"6a5dc9adf1c10c8ce825acf4","lab_id":"69ad52a3de79e566650fb1bf","country":"PL","accr_number":"AB 325","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Zawartość rtęci","methodology_en":"Mercury content","parameters":[{"name":"Zakres","range":"(0,1 – 20) mg/kg"}],"parameters_en":[{"name":"Range","range":"(0,1 – 20) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)"],"technique_en":"Cold vapour atomic absorption spectrometry (CVAAS)","computed":[],"computed_en":[],"activity":"Zawartość rtęci\nZakres (0,1 – 20) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"PB-20, wydanie 2 z dnia 30.08.2017 r.","norm_bases":["PB-20, wydanie 2 z dnia 30.08.2017 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Zawartość rtęci\nZakres (0,1 – 20) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PB-20, wydanie 2 z dnia 30.08.2017 r. Gleba Zawartosc rteci\nZakres (0,1 – 20) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PB-20, wydanie 2 z dnia 30.08.2017 r.","categories":["environment"],"row_index":21,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Soil Mercury content Cold vapour atomic absorption spectrometry (CVAAS) Range PB-20, wydanie 2 z dnia 30.08.2017 r.","methodology_zh":"汞含量","parameters_zh":[{"name":"范围","range":"(0,1 – 20) mg/kg"}],"search_zh":"土壤 汞含量 冷蒸气原子吸收光谱法（CVAAS） 范围 PB-20, wydanie 2 z dnia 30.08.2017 r.","technique_zh":"冷蒸气原子吸收光谱法（CVAAS）","test_object_zh":"土壤"},{"_id":"6a5dc9adf1c10c8ce825acf5","lab_id":"69ad52a3de79e566650fb1bf","country":"PL","accr_number":"AB 325","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Zawartość arsenu","methodology_en":"Arsenic content","parameters":[{"name":"Zakres","range":"(0,40 – 400) mg/kg"}],"parameters_en":[{"name":"Range","range":"(0,40 – 400) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem wodorków (HGAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem wodorków (HGAAS)"],"technique_en":"Hydride generation atomic absorption spectrometry (HGAAS)","computed":[],"computed_en":[],"activity":"Zawartość arsenu\nZakres (0,40 – 400) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem wodorków (HGAAS)","reference":"PB-08/4, wydanie 5 z dnia 30.08.2017 r.","norm_bases":["PB-08/4, wydanie 5 z dnia 30.08.2017 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Zawartość arsenu\nZakres (0,40 – 400) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem wodorków (HGAAS) PB-08/4, wydanie 5 z dnia 30.08.2017 r. Gleba Zawartosc arsenu\nZakres (0,40 – 400) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem wodorkow (HGAAS) PB-08/4, wydanie 5 z dnia 30.08.2017 r.","categories":["environment"],"row_index":22,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Soil Arsenic content Hydride generation atomic absorption spectrometry (HGAAS) Range PB-08/4, wydanie 5 z dnia 30.08.2017 r.","parameters_zh":[{"name":"范围","range":"(0,40 – 400) mg/kg"}],"search_zh":"土壤 砷含量 氢化物发生原子吸收光谱法（HGAAS） 范围 PB-08/4, wydanie 5 z dnia 30.08.2017 r.","test_object_zh":"土壤","technique_zh":"氢化物发生原子吸收光谱法（HGAAS）","methodology_zh":"砷含量"},{"_id":"6a5dc9adf1c10c8ce825acf6","lab_id":"69ad52a3de79e566650fb1bf","country":"PL","accr_number":"AB 325","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Stężenie metali","methodology_en":"Metal concentrations","parameters":[{"name":"cynk","range":"(5,0 – 10000) mg/kg"},{"name":"kadm","range":"(2,0 – 1000) mg/kg"},{"name":"ołów","range":"(20 – 2000) mg/kg"},{"name":"chrom","range":"(3,0 – 1000) mg/kg"},{"name":"miedź","range":"(5,0 – 1000) mg/kg"},{"name":"nikiel","range":"(3,0 – 1000) mg/kg"},{"name":"kobalt","range":"(5,0 – 1000) mg/kg"},{"name":"bar","range":"(10 – 1000) mg/kg"},{"name":"molibden","range":"(10 – 1000) mg/kg"},{"name":"cyna","range":"(10 – 1000) mg/kg"}],"parameters_en":[{"name":"zinc","range":"(5,0 – 10000) mg/kg"},{"name":"cadmium","range":"(2,0 – 1000) mg/kg"},{"name":"lead","range":"(20 – 2000) mg/kg"},{"name":"chromium","range":"(3,0 – 1000) mg/kg"},{"name":"copper","range":"(5,0 – 1000) mg/kg"},{"name":"nickel","range":"(3,0 – 1000) mg/kg"},{"name":"cobalt","range":"(5,0 – 1000) mg/kg"},{"name":"barium","range":"(10 – 1000) mg/kg"},{"name":"molybdenum","range":"(10 – 1000) mg/kg"},{"name":"tin","range":"(10 – 1000) mg/kg"}],"technique":"Metoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","computed":[],"computed_en":[],"activity":"Stężenie metali\nZakres:\ncynk (5,0 – 10000) mg/kg\nkadm (2,0 – 1000) mg/kg\nołów (20 – 2000) mg/kg\nchrom (3,0 – 1000) mg/kg\nmiedź (5,0 – 1000) mg/kg\nnikiel (3,0 – 1000) mg/kg\nkobalt (5,0 – 1000) mg/kg\nbar (10 – 1000) mg/kg\nmolibden (10 – 1000) mg/kg\ncyna (10 – 1000) mg/kg\nMetoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PB-08/2, wydanie 6 z dnia 28.06.2019 r.","norm_bases":["PB-08/2, wydanie 6 z dnia 28.06.2019 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Stężenie metali\nZakres:\ncynk (5,0 – 10000) mg/kg\nkadm (2,0 – 1000) mg/kg\nołów (20 – 2000) mg/kg\nchrom (3,0 – 1000) mg/kg\nmiedź (5,0 – 1000) mg/kg\nnikiel (3,0 – 1000) mg/kg\nkobalt (5,0 – 1000) mg/kg\nbar (10 – 1000) mg/kg\nmolibden (10 – 1000) mg/kg\ncyna (10 – 1000) mg/kg\nMetoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PB-08/2, wydanie 6 z dnia 28.06.2019 r. Gleba Stezenie metali\nZakres:\ncynk (5,0 – 10000) mg/kg\nkadm (2,0 – 1000) mg/kg\nolow (20 – 2000) mg/kg\nchrom (3,0 – 1000) mg/kg\nmiedz (5,0 – 1000) mg/kg\nnikiel (3,0 – 1000) mg/kg\nkobalt (5,0 – 1000) mg/kg\nbar (10 – 1000) mg/kg\nmolibden (10 – 1000) mg/kg\ncyna (10 – 1000) mg/kg\nMetoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PB-08/2, wydanie 6 z dnia 28.06.2019 r.","categories":["materials","environment"],"row_index":23,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Soil Metal concentrations Inductively coupled plasma optical emission spectrometry (ICP-OES) zinc cadmium lead chromium copper nickel cobalt barium molybdenum tin PB-08/2, wydanie 6 z dnia 28.06.2019 r.","methodology_zh":"金属浓度","parameters_zh":[{"name":"锌","range":"(5,0 – 10000) mg/kg"},{"name":"镉","range":"(2,0 – 1000) mg/kg"},{"name":"铅","range":"(20 – 2000) mg/kg"},{"name":"铬","range":"(3,0 – 1000) mg/kg"},{"name":"铜","range":"(5,0 – 1000) mg/kg"},{"name":"镍","range":"(3,0 – 1000) mg/kg"},{"name":"钴","range":"(5,0 – 1000) mg/kg"},{"name":"钡","range":"(10 – 1000) mg/kg"},{"name":"钼","range":"(10 – 1000) mg/kg"},{"name":"锡","range":"(10 – 1000) mg/kg"}],"search_zh":"土壤 金属浓度 电感耦合等离子体发射光谱法（ICP-OES） 锌 镉 铅 铬 铜 镍 钴 钡 钼 锡 PB-08/2, wydanie 6 z dnia 28.06.2019 r.","test_object_zh":"土壤","technique_zh":"电感耦合等离子体发射光谱法（ICP-OES）"},{"_id":"6a5dc9adf1c10c8ce825acf7","lab_id":"69ad52a3de79e566650fb1bf","country":"PL","accr_number":"AB 325","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Zawartość suchej masy / zawartość wody","methodology_en":"Dry matter content / water content","parameters":[{"name":"Zakres","range":"(0,1 – 99,9) %"}],"parameters_en":[{"name":"Range","range":"(0,1 – 99,9) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość suchej masy / zawartość wody\nZakres (0,1 – 99,9) %\nMetoda wagowa","reference":"PN-ISO 11465:1999","norm_bases":["PN-ISO 11465:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Zawartość suchej masy / zawartość wody\nZakres (0,1 – 99,9) %\nMetoda wagowa PN-ISO 11465:1999 Gleba Zawartosc suchej masy / zawartosc wody\nZakres (0,1 – 99,9) %\nMetoda wagowa PN-ISO 11465:1999","categories":["water","environment"],"row_index":24,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Soil Dry matter content / water content Gravimetric method Range PN-ISO 11465:1999","parameters_zh":[{"name":"范围","range":"(0,1 – 99,9) %"}],"search_zh":"土壤 干物质含量/水分含量 重量法 范围 PN-ISO 11465:1999","technique_zh":"重量法","test_object_zh":"土壤","methodology_zh":"干物质含量/水分含量"},{"_id":"6a5dc9adf1c10c8ce825acf8","lab_id":"69ad52a3de79e566650fb1bf","country":"PL","accr_number":"AB 325","accr_body":"PCA","test_object":"Odpady: kod 20 03 01, 19 12 10, 19 12 12 19 05 99","test_object_en":"Waste: code 20 03 01, 19 12 10, 19 12 12 19 05 99","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-EN 14899:2006","norm_bases":["PN-EN 14899:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady: kod 20 03 01, 19 12 10, 19 12 12 19 05 99 Pobieranie próbek do badań chemicznych i fizycznych PN-EN 14899:2006 Odpady: kod 20 03 01, 19 12 10, 19 12 12 19 05 99 Pobieranie probek do badan chemicznych i fizycznych PN-EN 14899:2006","categories":["environment"],"row_index":25,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste: code 20 03 01, 19 12 10, 19 12 12 19 05 99 Sampling for chemical and physical testing PN-EN 14899:2006","methodology_zh":"化学与物理检测用样品采集","search_zh":"化学与物理检测用样品采集 PN-EN 14899:2006"},{"_id":"6a5dc9adf1c10c8ce825acf9","lab_id":"69ad52a3de79e566650fb1bf","country":"PL","accr_number":"AB 325","accr_body":"PCA","test_object":"Odpady: kod 02 07 99, 03 03 07, 10 01 82 10 01 02, 10 02 08, 12 01 15 16 07 99, 19 05 01, 19 05 03 19 05 99, 19 10 04, 19 12 09 19 12 10, 19 12 12, 20 03 01","test_object_en":"Waste: code 02 07 99, 03 03 07, 10 01 82 10 01 02, 10 02 08, 12 01 15 16 07 99, 19 05 01, 19 05 03 19 05 99, 19 10 04, 19 12 09 19 12 10, 19 12 12, 20 03 01","methodology":"Zawartość suchej masy / zawartość wody","methodology_en":"Dry matter content / water content","parameters":[{"name":"Zakres","range":"(0,1 – 99,9) %"}],"parameters_en":[{"name":"Range","range":"(0,1 – 99,9) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość suchej masy / zawartość wody\nZakres (0,1 – 99,9) %\nMetoda wagowa","reference":"PN-ISO 11465:1999","norm_bases":["PN-ISO 11465:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady: kod 02 07 99, 03 03 07, 10 01 82 10 01 02, 10 02 08, 12 01 15 16 07 99, 19 05 01, 19 05 03 19 05 99, 19 10 04, 19 12 09 19 12 10, 19 12 12, 20 03 01 Zawartość suchej masy / zawartość wody\nZakres (0,1 – 99,9) %\nMetoda wagowa PN-ISO 11465:1999 Odpady: kod 02 07 99, 03 03 07, 10 01 82 10 01 02, 10 02 08, 12 01 15 16 07 99, 19 05 01, 19 05 03 19 05 99, 19 10 04, 19 12 09 19 12 10, 19 12 12, 20 03 01 Zawartosc suchej masy / zawartosc wody\nZakres (0,1 – 99,9) %\nMetoda wagowa PN-ISO 11465:1999","categories":["environment","water"],"row_index":26,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste: code 02 07 99, 03 03 07, 10 01 82 10 01 02, 10 02 08, 12 01 15 16 07 99, 19 05 01, 19 05 03 19 05 99, 19 10 04, 19 12 09 19 12 10, 19 12 12, 20 03 01 Dry matter content / water content Gravimetric method Range PN-ISO 11465:1999","parameters_zh":[{"name":"范围","range":"(0,1 – 99,9) %"}],"search_zh":"干物质含量/水分含量 重量法 范围 PN-ISO 11465:1999","technique_zh":"重量法","methodology_zh":"干物质含量/水分含量"},{"_id":"6a5dc9adf1c10c8ce825acfa","lab_id":"69ad52a3de79e566650fb1bf","country":"PL","accr_number":"AB 325","accr_body":"PCA","test_object":"Odpady: kod 02 07 99, 03 03 07, 10 01 82 10 01 02, 10 02 08, 12 01 15 16 07 99, 19 05 01, 19 05 03 19 12 10, 19 12 12, 19 05 99 19 10 04, 19 12 09","test_object_en":"Waste: code 02 07 99, 03 03 07, 10 01 82 10 01 02, 10 02 08, 12 01 15 16 07 99, 19 05 01, 19 05 03 19 12 10, 19 12 12, 19 05 99 19 10 04, 19 12 09","methodology":"Stężenie i zawartość ogólnego węgla organicznego (OWO)","methodology_en":"Total organic carbon (TOC) concentration and content","parameters":[{"name":"Zakres","range":"(1,0 – 1000) mg/l"},{"name":"Zakres","range":"(10,0 – 10000) mg/kg"}],"parameters_en":[{"name":"Range","range":"(1,0 – 1000) mg/l"},{"name":"Range","range":"(10,0 – 10000) mg/kg"}],"technique":"Metoda spektrometrii w podczerwieni (IR)","techniques":["Metoda spektrometrii w podczerwieni (IR)"],"technique_en":"Infrared spectrometry method (IR)","computed":[],"computed_en":[],"activity":"Stężenie i zawartość ogólnego węgla organicznego (OWO)\nZakres:\nZakres (1,0 – 1000) mg/l\nZakres (10,0 – 10000) mg/kg\nMetoda spektrometrii w podczerwieni (IR)","reference":"PN-EN 1484:1999 | PN-EN 12457-2:2006","norm_bases":["PN-EN 1484:1999","PN-EN 12457-2:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady: kod 02 07 99, 03 03 07, 10 01 82 10 01 02, 10 02 08, 12 01 15 16 07 99, 19 05 01, 19 05 03 19 12 10, 19 12 12, 19 05 99 19 10 04, 19 12 09 Stężenie i zawartość ogólnego węgla organicznego (OWO)\nZakres:\nZakres (1,0 – 1000) mg/l\nZakres (10,0 – 10000) mg/kg\nMetoda spektrometrii w podczerwieni (IR) PN-EN 1484:1999 | PN-EN 12457-2:2006 Odpady: kod 02 07 99, 03 03 07, 10 01 82 10 01 02, 10 02 08, 12 01 15 16 07 99, 19 05 01, 19 05 03 19 12 10, 19 12 12, 19 05 99 19 10 04, 19 12 09 Stezenie i zawartosc ogolnego wegla organicznego (OWO)\nZakres:\nZakres (1,0 – 1000) mg/l\nZakres (10,0 – 10000) mg/kg\nMetoda spektrometrii w podczerwieni (IR) PN-EN 1484:1999 | PN-EN 12457-2:2006","categories":["environment"],"row_index":27,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste: code 02 07 99, 03 03 07, 10 01 82 10 01 02, 10 02 08, 12 01 15 16 07 99, 19 05 01, 19 05 03 19 12 10, 19 12 12, 19 05 99 19 10 04, 19 12 09 Total organic carbon (TOC) concentration and content Infrared spectrometry method (IR) Range Range PN-EN 1484:1999 | PN-EN 12457-2:2006","parameters_zh":[{"name":"范围","range":"(1,0 – 1000) mg/l"},{"name":"范围","range":"(10,0 – 10000) mg/kg"}],"search_zh":"废物：代码 02 07 99、03 03 07、10 01 82、10 01 02、10 02 08、12 01 15、16 07 99、19 05 01、19 05 03、19 12 10、19 12 12、19 05 99、19 10 04、19 12 09 红外光谱法（IR） 范围 范围 PN-EN 1484:1999 | PN-EN 12457-2:2006","technique_zh":"红外光谱法（IR）","test_object_zh":"废物：代码 02 07 99、03 03 07、10 01 82、10 01 02、10 02 08、12 01 15、16 07 99、19 05 01、19 05 03、19 12 10、19 12 12、19 05 99、19 10 04、19 12 09"},{"_id":"6a5dc9adf1c10c8ce825acfb","lab_id":"69ad52a3de79e566650fb1bf","country":"PL","accr_number":"AB 325","accr_body":"PCA","test_object":"Odpady: kod 02 07 99, 03 03 07, 10 01 82 10 01 02, 10 02 08, 12 01 15 16 07 99, 19 05 01, 19 05 03 19 12 10, 19 12 12, 19 05 99 19 10 04, 19 12 09","test_object_en":"Waste: code 02 07 99, 03 03 07, 10 01 82 10 01 02, 10 02 08, 12 01 15 16 07 99, 19 05 01, 19 05 03 19 12 10, 19 12 12, 19 05 99 19 10 04, 19 12 09","methodology":"Całkowite substancje rozpuszczone (TDS)","methodology_en":"Total dissolved solids (TDS)","parameters":[{"name":"Zakres","range":"(10 – 20 000) mg/l"},{"name":"Zakres","range":"(100 – 200 000) mg/kg"}],"parameters_en":[{"name":"Range","range":"(10 – 20 000) mg/l"},{"name":"Range","range":"(100 – 200 000) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Całkowite substancje rozpuszczone (TDS)\nZakres:\nZakres (10 – 20 000) mg/l\nZakres (100 – 200 000) mg/kg\nMetoda wagowa","reference":"PN-EN 15216:2022-03 | PN-EN 12457-2:2006","norm_bases":["PN-EN 15216:2022-03","PN-EN 12457-2:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady: kod 02 07 99, 03 03 07, 10 01 82 10 01 02, 10 02 08, 12 01 15 16 07 99, 19 05 01, 19 05 03 19 12 10, 19 12 12, 19 05 99 19 10 04, 19 12 09 Całkowite substancje rozpuszczone (TDS)\nZakres:\nZakres (10 – 20 000) mg/l\nZakres (100 – 200 000) mg/kg\nMetoda wagowa PN-EN 15216:2022-03 | PN-EN 12457-2:2006 Odpady: kod 02 07 99, 03 03 07, 10 01 82 10 01 02, 10 02 08, 12 01 15 16 07 99, 19 05 01, 19 05 03 19 12 10, 19 12 12, 19 05 99 19 10 04, 19 12 09 Calkowite substancje rozpuszczone (TDS)\nZakres:\nZakres (10 – 20 000) mg/l\nZakres (100 – 200 000) mg/kg\nMetoda wagowa PN-EN 15216:2022-03 | PN-EN 12457-2:2006","categories":["environment"],"row_index":28,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste: code 02 07 99, 03 03 07, 10 01 82 10 01 02, 10 02 08, 12 01 15 16 07 99, 19 05 01, 19 05 03 19 12 10, 19 12 12, 19 05 99 19 10 04, 19 12 09 Total dissolved solids (TDS) Gravimetric method Range Range PN-EN 15216:2022-03 | PN-EN 12457-2:2006","parameters_zh":[{"name":"范围","range":"(10 – 20 000) mg/l"},{"name":"范围","range":"(100 – 200 000) mg/kg"}],"search_zh":"废物：代码 02 07 99、03 03 07、10 01 82、10 01 02、10 02 08、12 01 15、16 07 99、19 05 01、19 05 03、19 12 10、19 12 12、19 05 99、19 10 04、19 12 09 溶解性总固体（TDS） 重量法 范围 范围 PN-EN 15216:2022-03 | PN-EN 12457-2:2006","technique_zh":"重量法","methodology_zh":"溶解性总固体（TDS）","test_object_zh":"废物：代码 02 07 99、03 03 07、10 01 82、10 01 02、10 02 08、12 01 15、16 07 99、19 05 01、19 05 03、19 12 10、19 12 12、19 05 99、19 10 04、19 12 09"},{"_id":"6a5dc9adf1c10c8ce825acfc","lab_id":"69ad52a3de79e566650fb1bf","country":"PL","accr_number":"AB 325","accr_body":"PCA","test_object":"Odpady: kod 02 07 99, 03 03 07, 10 01 82 10 01 02, 10 02 08, 12 01 15 16 07 99, 19 05 01, 19 05 03 19 12 10, 19 12 12, 19 05 99 19 10 04, 19 12 09","test_object_en":"Waste: code 02 07 99, 03 03 07, 10 01 82 10 01 02, 10 02 08, 12 01 15 16 07 99, 19 05 01, 19 05 03 19 12 10, 19 12 12, 19 05 99 19 10 04, 19 12 09","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"2,0 – 13,0"}],"parameters_en":[{"name":"Range","range":"2,0 – 13,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 2,0 – 13,0\nMetoda potencjometryczna","reference":"PB-18, wydanie 2 z dnia 30.08.2017 r. | PN-EN 12457-2:2006","norm_bases":["PB-18, wydanie 2 z dnia 30.08.2017 r.","PN-EN 12457-2:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady: kod 02 07 99, 03 03 07, 10 01 82 10 01 02, 10 02 08, 12 01 15 16 07 99, 19 05 01, 19 05 03 19 12 10, 19 12 12, 19 05 99 19 10 04, 19 12 09 pH\nZakres 2,0 – 13,0\nMetoda potencjometryczna PB-18, wydanie 2 z dnia 30.08.2017 r. | PN-EN 12457-2:2006 Odpady: kod 02 07 99, 03 03 07, 10 01 82 10 01 02, 10 02 08, 12 01 15 16 07 99, 19 05 01, 19 05 03 19 12 10, 19 12 12, 19 05 99 19 10 04, 19 12 09 pH\nZakres 2,0 – 13,0\nMetoda potencjometryczna PB-18, wydanie 2 z dnia 30.08.2017 r. | PN-EN 12457-2:2006","categories":["environment"],"row_index":29,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste: code 02 07 99, 03 03 07, 10 01 82 10 01 02, 10 02 08, 12 01 15 16 07 99, 19 05 01, 19 05 03 19 12 10, 19 12 12, 19 05 99 19 10 04, 19 12 09 pH Potentiometric method Range PB-18, wydanie 2 z dnia 30.08.2017 r. | PN-EN 12457-2:2006","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 13,0"}],"search_zh":"废物：代码 02 07 99、03 03 07、10 01 82、10 01 02、10 02 08、12 01 15、16 07 99、19 05 01、19 05 03、19 12 10、19 12 12、19 05 99、19 10 04、19 12 09 pH 值 电位法 范围 PB-18, wydanie 2 z dnia 30.08.2017 r. | PN-EN 12457-2:2006","technique_zh":"电位法","test_object_zh":"废物：代码 02 07 99、03 03 07、10 01 82、10 01 02、10 02 08、12 01 15、16 07 99、19 05 01、19 05 03、19 12 10、19 12 12、19 05 99、19 10 04、19 12 09"},{"_id":"6a5dc9adf1c10c8ce825acfd","lab_id":"69ad52a3de79e566650fb1bf","country":"PL","accr_number":"AB 325","accr_body":"PCA","test_object":"Odpady: kod 02 07 99, 03 03 07, 10 01 82 10 01 02, 10 02 08, 12 01 15 16 07 99, 19 05 01, 19 05 03 19 12 10, 19 12 12, 19 05 99 19 10 04, 19 12 09","test_object_en":"Waste: code 02 07 99, 03 03 07, 10 01 82 10 01 02, 10 02 08, 12 01 15 16 07 99, 19 05 01, 19 05 03 19 12 10, 19 12 12, 19 05 99 19 10 04, 19 12 09","methodology":"Przewodność elektryczna właściwa","methodology_en":"Electrical conductivity","parameters":[{"name":"Zakres","range":"(10 – 25000) μS/cm"}],"parameters_en":[{"name":"Range","range":"(10 – 25000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"technique_en":"Conductometric method","computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa\nZakres (10 – 25000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999 | PN-EN 12457-2:2006","norm_bases":["PN-EN 27888:1999","PN-EN 12457-2:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady: kod 02 07 99, 03 03 07, 10 01 82 10 01 02, 10 02 08, 12 01 15 16 07 99, 19 05 01, 19 05 03 19 12 10, 19 12 12, 19 05 99 19 10 04, 19 12 09 Przewodność elektryczna właściwa\nZakres (10 – 25000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 | PN-EN 12457-2:2006 Odpady: kod 02 07 99, 03 03 07, 10 01 82 10 01 02, 10 02 08, 12 01 15 16 07 99, 19 05 01, 19 05 03 19 12 10, 19 12 12, 19 05 99 19 10 04, 19 12 09 Przewodnosc elektryczna wlasciwa\nZakres (10 – 25000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 | PN-EN 12457-2:2006","categories":["environment"],"row_index":30,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste: code 02 07 99, 03 03 07, 10 01 82 10 01 02, 10 02 08, 12 01 15 16 07 99, 19 05 01, 19 05 03 19 12 10, 19 12 12, 19 05 99 19 10 04, 19 12 09 Electrical conductivity Conductometric method Range PN-EN 27888:1999 | PN-EN 12457-2:2006","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(10 – 25000) μS/cm"}],"search_zh":"废物：代码 02 07 99、03 03 07、10 01 82、10 01 02、10 02 08、12 01 15、16 07 99、19 05 01、19 05 03、19 12 10、19 12 12、19 05 99、19 10 04、19 12 09 电导率 电导法 范围 PN-EN 27888:1999 | PN-EN 12457-2:2006","technique_zh":"电导法","test_object_zh":"废物：代码 02 07 99、03 03 07、10 01 82、10 01 02、10 02 08、12 01 15、16 07 99、19 05 01、19 05 03、19 12 10、19 12 12、19 05 99、19 10 04、19 12 09"},{"_id":"6a5dc9adf1c10c8ce825acfe","lab_id":"69ad52a3de79e566650fb1bf","country":"PL","accr_number":"AB 325","accr_body":"PCA","test_object":"Odpady: kod 02 07 99, 03 03 07, 10 01 82 10 01 02, 10 02 08, 12 01 15 16 07 99, 19 05 01, 19 05 03 19 12 10, 19 12 12, 19 05 99 19 10 04, 19 12 09","test_object_en":"Waste: code 02 07 99, 03 03 07, 10 01 82 10 01 02, 10 02 08, 12 01 15 16 07 99, 19 05 01, 19 05 03 19 12 10, 19 12 12, 19 05 99 19 10 04, 19 12 09","methodology":"Stężenie i zawartość chlorków","methodology_en":"Chloride concentration and content","parameters":[{"name":"Zakres","range":"(5,0 – 400) mg/l"},{"name":"Zakres","range":"(50 – 4000) mg/kg"}],"parameters_en":[{"name":"Range","range":"(5,0 – 400) mg/l"},{"name":"Range","range":"(50 – 4000) mg/kg"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie i zawartość chlorków\nZakres:\nZakres (5,0 – 400) mg/l\nZakres (50 – 4000) mg/kg\nMetoda miareczkowa","reference":"PN-ISO 9297:1994 | PN-EN 12457-2:2006","norm_bases":["PN-ISO 9297:1994","PN-EN 12457-2:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady: kod 02 07 99, 03 03 07, 10 01 82 10 01 02, 10 02 08, 12 01 15 16 07 99, 19 05 01, 19 05 03 19 12 10, 19 12 12, 19 05 99 19 10 04, 19 12 09 Stężenie i zawartość chlorków\nZakres:\nZakres (5,0 – 400) mg/l\nZakres (50 – 4000) mg/kg\nMetoda miareczkowa PN-ISO 9297:1994 | PN-EN 12457-2:2006 Odpady: kod 02 07 99, 03 03 07, 10 01 82 10 01 02, 10 02 08, 12 01 15 16 07 99, 19 05 01, 19 05 03 19 12 10, 19 12 12, 19 05 99 19 10 04, 19 12 09 Stezenie i zawartosc chlorkow\nZakres:\nZakres (5,0 – 400) mg/l\nZakres (50 – 4000) mg/kg\nMetoda miareczkowa PN-ISO 9297:1994 | PN-EN 12457-2:2006","categories":["environment"],"row_index":31,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste: code 02 07 99, 03 03 07, 10 01 82 10 01 02, 10 02 08, 12 01 15 16 07 99, 19 05 01, 19 05 03 19 12 10, 19 12 12, 19 05 99 19 10 04, 19 12 09 Chloride concentration and content Titrimetric method Range Range PN-ISO 9297:1994 | PN-EN 12457-2:2006","parameters_zh":[{"name":"范围","range":"(5,0 – 400) mg/l"},{"name":"范围","range":"(50 – 4000) mg/kg"}],"search_zh":"废物：代码 02 07 99、03 03 07、10 01 82、10 01 02、10 02 08、12 01 15、16 07 99、19 05 01、19 05 03、19 12 10、19 12 12、19 05 99、19 10 04、19 12 09 氯化物的浓度与含量 滴定法 范围 范围 PN-ISO 9297:1994 | PN-EN 12457-2:2006","technique_zh":"滴定法","test_object_zh":"废物：代码 02 07 99、03 03 07、10 01 82、10 01 02、10 02 08、12 01 15、16 07 99、19 05 01、19 05 03、19 12 10、19 12 12、19 05 99、19 10 04、19 12 09","methodology_zh":"氯化物的浓度与含量"},{"_id":"6a5dc9adf1c10c8ce825acff","lab_id":"69ad52a3de79e566650fb1bf","country":"PL","accr_number":"AB 325","accr_body":"PCA","test_object":"Odpady: kod 02 07 99, 03 03 07, 10 01 82 10 01 02, 10 02 08, 12 01 15 16 07 99, 19 05 01, 19 05 03 19 12 10, 19 12 12, 19 05 99 19 10 04, 19 12 09","test_object_en":"Waste: code 02 07 99, 03 03 07, 10 01 82 10 01 02, 10 02 08, 12 01 15 16 07 99, 19 05 01, 19 05 03 19 12 10, 19 12 12, 19 05 99 19 10 04, 19 12 09","methodology":"Stężenie i zawartość siarczanów (VI)","methodology_en":"Sulphate (VI) concentration and content","parameters":[{"name":"Zakres","range":"(10 – 5000) mg/l"},{"name":"Zakres","range":"(100 – 50000) mg/kg"}],"parameters_en":[{"name":"Range","range":"(10 – 5000) mg/l"},{"name":"Range","range":"(100 – 50000) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie i zawartość siarczanów (VI)\nZakres:\nZakres (10 – 5000) mg/l\nZakres (100 – 50000) mg/kg\nMetoda wagowa","reference":"PN-ISO 9280:2002 | PN-EN 12457-2:2006","norm_bases":["PN-ISO 9280:2002","PN-EN 12457-2:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady: kod 02 07 99, 03 03 07, 10 01 82 10 01 02, 10 02 08, 12 01 15 16 07 99, 19 05 01, 19 05 03 19 12 10, 19 12 12, 19 05 99 19 10 04, 19 12 09 Stężenie i zawartość siarczanów (VI)\nZakres:\nZakres (10 – 5000) mg/l\nZakres (100 – 50000) mg/kg\nMetoda wagowa PN-ISO 9280:2002 | PN-EN 12457-2:2006 Odpady: kod 02 07 99, 03 03 07, 10 01 82 10 01 02, 10 02 08, 12 01 15 16 07 99, 19 05 01, 19 05 03 19 12 10, 19 12 12, 19 05 99 19 10 04, 19 12 09 Stezenie i zawartosc siarczanow (VI)\nZakres:\nZakres (10 – 5000) mg/l\nZakres (100 – 50000) mg/kg\nMetoda wagowa PN-ISO 9280:2002 | PN-EN 12457-2:2006","categories":["environment"],"row_index":32,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste: code 02 07 99, 03 03 07, 10 01 82 10 01 02, 10 02 08, 12 01 15 16 07 99, 19 05 01, 19 05 03 19 12 10, 19 12 12, 19 05 99 19 10 04, 19 12 09 Sulphate (VI) concentration and content Gravimetric method Range Range PN-ISO 9280:2002 | PN-EN 12457-2:2006","parameters_zh":[{"name":"范围","range":"(10 – 5000) mg/l"},{"name":"范围","range":"(100 – 50000) mg/kg"}],"search_zh":"废物：代码 02 07 99、03 03 07、10 01 82、10 01 02、10 02 08、12 01 15、16 07 99、19 05 01、19 05 03、19 12 10、19 12 12、19 05 99、19 10 04、19 12 09 重量法 范围 范围 PN-ISO 9280:2002 | PN-EN 12457-2:2006","technique_zh":"重量法","test_object_zh":"废物：代码 02 07 99、03 03 07、10 01 82、10 01 02、10 02 08、12 01 15、16 07 99、19 05 01、19 05 03、19 12 10、19 12 12、19 05 99、19 10 04、19 12 09"},{"_id":"6a5dc9adf1c10c8ce825ad00","lab_id":"69ad52a3de79e566650fb1bf","country":"PL","accr_number":"AB 325","accr_body":"PCA","test_object":"Odpady: kod 02 07 99, 03 03 07, 10 01 82 10 01 02, 10 02 08, 12 01 15 16 07 99, 19 05 01, 19 05 03 19 12 10, 19 12 12, 19 05 99 19 10 04, 19 12 09","test_object_en":"Waste: code 02 07 99, 03 03 07, 10 01 82 10 01 02, 10 02 08, 12 01 15 16 07 99, 19 05 01, 19 05 03 19 12 10, 19 12 12, 19 05 99 19 10 04, 19 12 09","methodology":"Stężenie i zawartość metali","methodology_en":"Concentration and content of metals","parameters":[{"name":"arsen","range":"(0,05 – 0,20 ) mg/kg"},{"name":"selen","range":"(0,05 – 0,25) mg/kg"},{"name":"antymon","range":"(0,07 – 0,25) mg/kg"}],"parameters_en":[{"name":"arsenic","range":"(0,05 – 0,20 ) mg/kg"},{"name":"selenium","range":"(0,05 – 0,25) mg/kg"},{"name":"antimony","range":"(0,07 – 0,25) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)"],"technique_en":"Electrothermal atomization atomic absorption spectrometry (ETAAS)","computed":[],"computed_en":[],"activity":"Stężenie i zawartość metali\nZakres:\narsen (0,05 – 0,20 ) mg/kg\nselen (0,05 – 0,25) mg/kg\nantymon (0,07 – 0,25) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","reference":"PB-05/5, wydanie 3 z dnia 30.08.2017 r. | PN-EN 12457-2:2006","norm_bases":["PB-05/5, wydanie 3 z dnia 30.08.2017 r.","PN-EN 12457-2:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady: kod 02 07 99, 03 03 07, 10 01 82 10 01 02, 10 02 08, 12 01 15 16 07 99, 19 05 01, 19 05 03 19 12 10, 19 12 12, 19 05 99 19 10 04, 19 12 09 Stężenie i zawartość metali\nZakres:\narsen (0,05 – 0,20 ) mg/kg\nselen (0,05 – 0,25) mg/kg\nantymon (0,07 – 0,25) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS) PB-05/5, wydanie 3 z dnia 30.08.2017 r. | PN-EN 12457-2:2006 Odpady: kod 02 07 99, 03 03 07, 10 01 82 10 01 02, 10 02 08, 12 01 15 16 07 99, 19 05 01, 19 05 03 19 12 10, 19 12 12, 19 05 99 19 10 04, 19 12 09 Stezenie i zawartosc metali\nZakres:\narsen (0,05 – 0,20 ) mg/kg\nselen (0,05 – 0,25) mg/kg\nantymon (0,07 – 0,25) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z atomizacja elektrotermiczna (ETAAS) PB-05/5, wydanie 3 z dnia 30.08.2017 r. | PN-EN 12457-2:2006","categories":["materials","environment"],"row_index":33,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste: code 02 07 99, 03 03 07, 10 01 82 10 01 02, 10 02 08, 12 01 15 16 07 99, 19 05 01, 19 05 03 19 12 10, 19 12 12, 19 05 99 19 10 04, 19 12 09 Concentration and content of metals Electrothermal atomization atomic absorption spectrometry (ETAAS) arsenic selenium antimony PB-05/5, wydanie 3 z dnia 30.08.2017 r. | PN-EN 12457-2:2006","search_zh":"废物：代码 02 07 99、03 03 07、10 01 82、10 01 02、10 02 08、12 01 15、16 07 99、19 05 01、19 05 03、19 12 10、19 12 12、19 05 99、19 10 04、19 12 09 电热原子化原子吸收光谱法（ETAAS） 砷 硒 锑 PB-05/5, wydanie 3 z dnia 30.08.2017 r. | PN-EN 12457-2:2006","technique_zh":"电热原子化原子吸收光谱法（ETAAS）","parameters_zh":[{"name":"砷","range":"(0,05 – 0,20 ) mg/kg"},{"name":"硒","range":"(0,05 – 0,25) mg/kg"},{"name":"锑","range":"(0,07 – 0,25) mg/kg"}],"test_object_zh":"废物：代码 02 07 99、03 03 07、10 01 82、10 01 02、10 02 08、12 01 15、16 07 99、19 05 01、19 05 03、19 12 10、19 12 12、19 05 99、19 10 04、19 12 09"},{"_id":"6a5dc9adf1c10c8ce825ad01","lab_id":"69ad52a3de79e566650fb1bf","country":"PL","accr_number":"AB 325","accr_body":"PCA","test_object":"Odpady: kod 20 03 01, 19 12 10, 19 12 12","test_object_en":"Waste: code 20 03 01, 19 12 10, 19 12 12","methodology":"Zawartość chloru","methodology_en":"Chlorine content","parameters":[{"name":"chlor","range":"(0,050 – 3,000) %"}],"parameters_en":[{"name":"chlorine","range":"(0,050 – 3,000) %"}],"technique":"Metoda turbidymetryczna","techniques":["Metoda turbidymetryczna"],"technique_en":"Turbidimetric method","computed":[],"computed_en":[],"activity":"Zawartość chloru\nchlor (0,050 – 3,000) %\nMetoda turbidymetryczna","reference":"PN-EN 14582:2017-02","norm_bases":["PN-EN 14582:2017-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady: kod 20 03 01, 19 12 10, 19 12 12 Zawartość chloru\nchlor (0,050 – 3,000) %\nMetoda turbidymetryczna PN-EN 14582:2017-02 Odpady: kod 20 03 01, 19 12 10, 19 12 12 Zawartosc chloru\nchlor (0,050 – 3,000) %\nMetoda turbidymetryczna PN-EN 14582:2017-02","categories":["environment"],"row_index":34,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste: code 20 03 01, 19 12 10, 19 12 12 Chlorine content Turbidimetric method chlorine PN-EN 14582:2017-02","methodology_zh":"氯含量","search_zh":"氯含量 浊度法 PN-EN 14582:2017-02","technique_zh":"浊度法"},{"_id":"6a5dc9adf1c10c8ce825ad02","lab_id":"69ad52a3de79e566650fb1bf","country":"PL","accr_number":"AB 325","accr_body":"PCA","test_object":"Odpady: kod 20 03 01, 19 12 10, 19 12 12, 19 05 99","test_object_en":"Waste: code 20 03 01, 19 12 10, 19 12 12, 19 05 99","methodology":"Straty przy prażeniu","methodology_en":"Loss on ignition","parameters":[{"name":"Zakres","range":"(5,0 – 99,9) %"}],"parameters_en":[{"name":"Range","range":"(5,0 – 99,9) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Straty przy prażeniu\nZakres (5,0 – 99,9) %\nMetoda wagowa","reference":"PN-EN 15935:2022-01","norm_bases":["PN-EN 15935:2022-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady: kod 20 03 01, 19 12 10, 19 12 12, 19 05 99 Straty przy prażeniu\nZakres (5,0 – 99,9) %\nMetoda wagowa PN-EN 15935:2022-01 Odpady: kod 20 03 01, 19 12 10, 19 12 12, 19 05 99 Straty przy prazeniu\nZakres (5,0 – 99,9) %\nMetoda wagowa PN-EN 15935:2022-01","categories":["environment"],"row_index":35,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste: code 20 03 01, 19 12 10, 19 12 12, 19 05 99 Loss on ignition Gravimetric method Range PN-EN 15935:2022-01","parameters_zh":[{"name":"范围","range":"(5,0 – 99,9) %"}],"search_zh":"废物：代码 20 03 01、19 12 10、19 12 12、19 05 99 烧失量 重量法 范围 PN-EN 15935:2022-01","technique_zh":"重量法","methodology_zh":"烧失量","test_object_zh":"废物：代码 20 03 01、19 12 10、19 12 12、19 05 99"},{"_id":"6a5dc9adf1c10c8ce825ad03","lab_id":"69ad52a3de79e566650fb1bf","country":"PL","accr_number":"AB 325","accr_body":"PCA","test_object":"Odpady: kod 20 03 01, 19 12 10, 19 12 12, 19 05 99","test_object_en":"Waste: code 20 03 01, 19 12 10, 19 12 12, 19 05 99","methodology":"Pozostałość po prażeniu","methodology_en":"Residue on ignition","parameters":[{"name":"Zakres","range":"(0,1 – 95,0) %"}],"parameters_en":[{"name":"Range","range":"(0,1 – 95,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Pozostałość po prażeniu\nZakres (0,1 – 95,0) %\nMetoda wagowa","reference":"PN-EN 15935:2022-01","norm_bases":["PN-EN 15935:2022-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady: kod 20 03 01, 19 12 10, 19 12 12, 19 05 99 Pozostałość po prażeniu\nZakres (0,1 – 95,0) %\nMetoda wagowa PN-EN 15935:2022-01 Odpady: kod 20 03 01, 19 12 10, 19 12 12, 19 05 99 Pozostalosc po prazeniu\nZakres (0,1 – 95,0) %\nMetoda wagowa PN-EN 15935:2022-01","categories":["environment"],"row_index":36,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste: code 20 03 01, 19 12 10, 19 12 12, 19 05 99 Residue on ignition Gravimetric method Range PN-EN 15935:2022-01","parameters_zh":[{"name":"范围","range":"(0,1 – 95,0) %"}],"search_zh":"废物：代码 20 03 01、19 12 10、19 12 12、19 05 99 灼烧残渣 重量法 范围 PN-EN 15935:2022-01","technique_zh":"重量法","methodology_zh":"灼烧残渣","test_object_zh":"废物：代码 20 03 01、19 12 10、19 12 12、19 05 99"},{"_id":"6a5dc9adf1c10c8ce825ad04","lab_id":"69ad52a3de79e566650fb1bf","country":"PL","accr_number":"AB 325","accr_body":"PCA","test_object":"Odpady: kod 20 03 01, 19 12 10, 19 12 12, 19 05 99","test_object_en":"Waste: code 20 03 01, 19 12 10, 19 12 12, 19 05 99","methodology":"Zawartość frakcji biodegradowalnej","methodology_en":"Biodegradable fraction content","parameters":[{"name":"udział masowy biomasy z zastosowaniem selektywnego rozpuszczania"},{"name":"Zakres","range":"(5,00 – 99,0) %"},{"name":"Zawartość frakcji niebiodegradowalnej"},{"name":"udział masowy niebiomasy (z obliczeń)"}],"parameters_en":[{"name":"mass fraction of biomass using selective dissolution"},{"name":"Range","range":"(5,00 – 99,0) %"},{"name":"Content of the non-biodegradable fraction"},{"name":"mass fraction of non-biomass (calculated)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość frakcji biodegradowalnej\nZakres:\nudział masowy biomasy z zastosowaniem selektywnego rozpuszczania\nZakres (5,00 – 99,0) %\nZawartość frakcji niebiodegradowalnej\nudział masowy niebiomasy (z obliczeń)\nMetoda wagowa","reference":"PN-EN ISO 21644:2021-07","norm_bases":["PN-EN ISO 21644:2021-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady: kod 20 03 01, 19 12 10, 19 12 12, 19 05 99 Zawartość frakcji biodegradowalnej\nZakres:\nudział masowy biomasy z zastosowaniem selektywnego rozpuszczania\nZakres (5,00 – 99,0) %\nZawartość frakcji niebiodegradowalnej\nudział masowy niebiomasy (z obliczeń)\nMetoda wagowa PN-EN ISO 21644:2021-07 Odpady: kod 20 03 01, 19 12 10, 19 12 12, 19 05 99 Zawartosc frakcji biodegradowalnej\nZakres:\nudzial masowy biomasy z zastosowaniem selektywnego rozpuszczania\nZakres (5,00 – 99,0) %\nZawartosc frakcji niebiodegradowalnej\nudzial masowy niebiomasy (z obliczen)\nMetoda wagowa PN-EN ISO 21644:2021-07","categories":["environment"],"row_index":37,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste: code 20 03 01, 19 12 10, 19 12 12, 19 05 99 Biodegradable fraction content Gravimetric method mass fraction of biomass using selective dissolution Range Content of the non-biodegradable fraction mass fraction of non-biomass (calculated) PN-EN ISO 21644:2021-07","parameters_zh":[{"name":"采用选择性溶解法测定的生物质质量分数"},{"name":"范围","range":"(5,00 – 99,0) %"},{"name":"不可生物降解组分含量"},{"name":"非生物质质量分数（由计算得出）"}],"search_zh":"废物：代码 20 03 01、19 12 10、19 12 12、19 05 99 可生物降解组分含量 重量法 采用选择性溶解法测定的生物质质量分数 范围 不可生物降解组分含量 非生物质质量分数（由计算得出） PN-EN ISO 21644:2021-07","technique_zh":"重量法","test_object_zh":"废物：代码 20 03 01、19 12 10、19 12 12、19 05 99","methodology_zh":"可生物降解组分含量"},{"_id":"6a5dc9adf1c10c8ce825ad05","lab_id":"69ad52a3de79e566650fb1bf","country":"PL","accr_number":"AB 325","accr_body":"PCA","test_object":"Odpady: kod 20 03 01, 19 12 10, 19 12 12, 19 05 99","test_object_en":"Waste: code 20 03 01, 19 12 10, 19 12 12, 19 05 99","methodology":"Zawartość wilgoci całkowitej","methodology_en":"Total moisture content","parameters":[{"name":"Zakres","range":"(1,0 – 80,0) %"}],"parameters_en":[{"name":"Range","range":"(1,0 – 80,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość wilgoci całkowitej\nZakres (1,0 – 80,0) %\nMetoda wagowa","reference":"SIST–TSCEN/TS 15414–1:2010","norm_bases":["SIST–TSCEN/TS 15414–1:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady: kod 20 03 01, 19 12 10, 19 12 12, 19 05 99 Zawartość wilgoci całkowitej\nZakres (1,0 – 80,0) %\nMetoda wagowa SIST–TSCEN/TS 15414–1:2010 Odpady: kod 20 03 01, 19 12 10, 19 12 12, 19 05 99 Zawartosc wilgoci calkowitej\nZakres (1,0 – 80,0) %\nMetoda wagowa SIST–TSCEN/TS 15414–1:2010","categories":["environment"],"row_index":38,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste: code 20 03 01, 19 12 10, 19 12 12, 19 05 99 Total moisture content Gravimetric method Range SIST–TSCEN/TS 15414–1:2010","methodology_zh":"全水分含量","parameters_zh":[{"name":"范围","range":"(1,0 – 80,0) %"}],"search_zh":"废物：代码 20 03 01、19 12 10、19 12 12、19 05 99 全水分含量 重量法 范围 SIST–TSCEN/TS 15414–1:2010","technique_zh":"重量法","test_object_zh":"废物：代码 20 03 01、19 12 10、19 12 12、19 05 99"},{"_id":"6a5dc9adf1c10c8ce825ad06","lab_id":"69ad52a3de79e566650fb1bf","country":"PL","accr_number":"AB 325","accr_body":"PCA","test_object":"Odpady: kod 20 03 01, 19 12 10, 19 12 12, 19 05 99","test_object_en":"Waste: code 20 03 01, 19 12 10, 19 12 12, 19 05 99","methodology":"Zawartość wilgoci w ogólnej próbce analitycznej","methodology_en":"Moisture content in the general analytical sample","parameters":[{"name":"Zakres","range":"(0,10 – 5,0) %"}],"parameters_en":[{"name":"Range","range":"(0,10 – 5,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość wilgoci w ogólnej próbce analitycznej\nZakres (0,10 – 5,0) %\nMetoda wagowa","reference":"PN-EN ISO 21660-3:2021-08","norm_bases":["PN-EN ISO 21660-3:2021-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady: kod 20 03 01, 19 12 10, 19 12 12, 19 05 99 Zawartość wilgoci w ogólnej próbce analitycznej\nZakres (0,10 – 5,0) %\nMetoda wagowa PN-EN ISO 21660-3:2021-08 Odpady: kod 20 03 01, 19 12 10, 19 12 12, 19 05 99 Zawartosc wilgoci w ogolnej probce analitycznej\nZakres (0,10 – 5,0) %\nMetoda wagowa PN-EN ISO 21660-3:2021-08","categories":["environment"],"row_index":39,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste: code 20 03 01, 19 12 10, 19 12 12, 19 05 99 Moisture content in the general analytical sample Gravimetric method Range PN-EN ISO 21660-3:2021-08","parameters_zh":[{"name":"范围","range":"(0,10 – 5,0) %"}],"search_zh":"废物：代码 20 03 01、19 12 10、19 12 12、19 05 99 总分析样品中的水分含量 重量法 范围 PN-EN ISO 21660-3:2021-08","technique_zh":"重量法","methodology_zh":"总分析样品中的水分含量","test_object_zh":"废物：代码 20 03 01、19 12 10、19 12 12、19 05 99"},{"_id":"6a5dc9adf1c10c8ce825ad07","lab_id":"69ad52a3de79e566650fb1bf","country":"PL","accr_number":"AB 325","accr_body":"PCA","test_object":"Odpady: kod 20 03 01, 19 12 10, 19 12 12, 19 05 99","test_object_en":"Waste: code 20 03 01, 19 12 10, 19 12 12, 19 05 99","methodology":"Zawartość popiołu","methodology_en":"Ash content","parameters":[{"name":"Zakres","range":"(0,90 – 83,0) %"}],"parameters_en":[{"name":"Range","range":"(0,90 – 83,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość popiołu\nZakres (0,90 – 83,0) %\nMetoda wagowa","reference":"PN-EN ISO 21656:2021-08","norm_bases":["PN-EN ISO 21656:2021-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady: kod 20 03 01, 19 12 10, 19 12 12, 19 05 99 Zawartość popiołu\nZakres (0,90 – 83,0) %\nMetoda wagowa PN-EN ISO 21656:2021-08 Odpady: kod 20 03 01, 19 12 10, 19 12 12, 19 05 99 Zawartosc popiolu\nZakres (0,90 – 83,0) %\nMetoda wagowa PN-EN ISO 21656:2021-08","categories":["environment"],"row_index":40,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste: code 20 03 01, 19 12 10, 19 12 12, 19 05 99 Ash content Gravimetric method Range PN-EN ISO 21656:2021-08","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(0,90 – 83,0) %"}],"search_zh":"废物：代码 20 03 01、19 12 10、19 12 12、19 05 99 灰分含量 重量法 范围 PN-EN ISO 21656:2021-08","technique_zh":"重量法","test_object_zh":"废物：代码 20 03 01、19 12 10、19 12 12、19 05 99"},{"_id":"6a5dc9adf1c10c8ce825ad08","lab_id":"69ad52a3de79e566650fb1bf","country":"PL","accr_number":"AB 325","accr_body":"PCA","test_object":"Odpady: kod 19 12 10","test_object_en":"Waste: code 19 12 10","methodology":"Zawartość rtęci","methodology_en":"Mercury content","parameters":[{"name":"Zakres","range":"(0,1 – 6,0) mg/kg"}],"parameters_en":[{"name":"Range","range":"(0,1 – 6,0) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","techniques":["Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji"],"technique_en":"Atomic absorption spectrometry with amalgamation technique","computed":[],"computed_en":[],"activity":"Zawartość rtęci\nZakres (0,1 – 6,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","reference":"PB-21, wydanie 3 z dnia 30.08.2017 r.","norm_bases":["PB-21, wydanie 3 z dnia 30.08.2017 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady: kod 19 12 10 Zawartość rtęci\nZakres (0,1 – 6,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji PB-21, wydanie 3 z dnia 30.08.2017 r. Odpady: kod 19 12 10 Zawartosc rteci\nZakres (0,1 – 6,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z technika amalgamacji PB-21, wydanie 3 z dnia 30.08.2017 r.","categories":["environment"],"row_index":41,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste: code 19 12 10 Mercury content Atomic absorption spectrometry with amalgamation technique Range PB-21, wydanie 3 z dnia 30.08.2017 r.","methodology_zh":"汞含量","parameters_zh":[{"name":"范围","range":"(0,1 – 6,0) mg/kg"}],"search_zh":"汞含量 原子吸收光谱法（汞齐化技术） 范围 PB-21, wydanie 3 z dnia 30.08.2017 r.","technique_zh":"原子吸收光谱法（汞齐化技术）"},{"_id":"6a5dc9adf1c10c8ce825ad09","lab_id":"69ad52a3de79e566650fb1bf","country":"PL","accr_number":"AB 325","accr_body":"PCA","test_object":"Odpady: kod 19 05 01, 19 05 03, 19 05 99","test_object_en":"Waste: code 19 05 01, 19 05 03, 19 05 99","methodology":"Aktywność oddechowa AT4","methodology_en":"Respiration activity AT4","parameters":[{"name":"Zakres","range":"(4,0 – 50,0) mg/g"}],"parameters_en":[{"name":"Range","range":"(4,0 – 50,0) mg/g"}],"technique":"Metoda manometryczna","techniques":["Metoda manometryczna"],"technique_en":"Manometric method","computed":[],"computed_en":[],"activity":"Aktywność oddechowa AT4\nZakres (4,0 – 50,0) mg/g\nMetoda manometryczna","reference":"ÖNORM S2027-4:2011","norm_bases":["ÖNORM S2027-4:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady: kod 19 05 01, 19 05 03, 19 05 99 Aktywność oddechowa AT4\nZakres (4,0 – 50,0) mg/g\nMetoda manometryczna ÖNORM S2027-4:2011 Odpady: kod 19 05 01, 19 05 03, 19 05 99 Aktywnosc oddechowa AT4\nZakres (4,0 – 50,0) mg/g\nMetoda manometryczna ONORM S2027-4:2011","categories":["environment","metrology"],"row_index":42,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste: code 19 05 01, 19 05 03, 19 05 99 Respiration activity AT4 Manometric method Range ÖNORM S2027-4:2011","parameters_zh":[{"name":"范围","range":"(4,0 – 50,0) mg/g"}],"search_zh":"呼吸活性 AT4 压力计法 范围 ÖNORM S2027-4:2011","technique_zh":"压力计法","methodology_zh":"呼吸活性 AT4"},{"_id":"6a5dc9adf1c10c8ce825ad0a","lab_id":"69ad52a3de79e566650fb1bf","country":"PL","accr_number":"AB 325","accr_body":"PCA","test_object":"Odpady: kod 19 12 10, 19 12 12, 20 03 01,","test_object_en":"Waste: code 19 12 10, 19 12 12, 20 03 01,","methodology":"Zawartość wodoru i węgla:","methodology_en":"Hydrogen and carbon content:","parameters":[{"name":"Wodór","range":"(4,00 – 11,00) %"},{"name":"Węgiel","range":"(35,0 – 70,0) %"}],"parameters_en":[{"name":"Hydrogen","range":"(4,00 – 11,00) %"},{"name":"Carbon","range":"(35,0 – 70,0) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"technique_en":"High-temperature combustion with IR detection","computed":[],"computed_en":[],"activity":"Zawartość wodoru i węgla:\nZakres:\nWodór (4,00 – 11,00) %\nWęgiel (35,0 – 70,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN ISO 21663:2021-06","norm_bases":["PN-EN ISO 21663:2021-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady: kod 19 12 10, 19 12 12, 20 03 01, Zawartość wodoru i węgla:\nZakres:\nWodór (4,00 – 11,00) %\nWęgiel (35,0 – 70,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN ISO 21663:2021-06 Odpady: kod 19 12 10, 19 12 12, 20 03 01, Zawartosc wodoru i wegla:\nZakres:\nWodor (4,00 – 11,00) %\nWegiel (35,0 – 70,0) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN ISO 21663:2021-06","categories":["environment"],"row_index":43,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste: code 19 12 10, 19 12 12, 20 03 01, Hydrogen and carbon content: High-temperature combustion with IR detection Hydrogen Carbon PN-EN ISO 21663:2021-06","search_zh":"高温燃烧红外检测法 氢 碳 PN-EN ISO 21663:2021-06","technique_zh":"高温燃烧红外检测法","parameters_zh":[{"name":"氢","range":"(4,00 – 11,00) %"},{"name":"碳","range":"(35,0 – 70,0) %"}]},{"_id":"6a5dc9adf1c10c8ce825ad0b","lab_id":"69ad52a3de79e566650fb1bf","country":"PL","accr_number":"AB 325","accr_body":"PCA","test_object":"Odpady: kod 19 12 10, 19 12 12, 20 03 01,","test_object_en":"Waste: code 19 12 10, 19 12 12, 20 03 01,","methodology":"Ciepło spalania","methodology_en":"Gross calorific value","parameters":[{"name":"Zakres","range":"(4000 – 33000) J/g"},{"name":"Wartość opałowa (z obliczeń)"}],"parameters_en":[{"name":"Range","range":"(4000 – 33000) J/g"},{"name":"Net calorific value (calculated)"}],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna"],"technique_en":"Calorimetric method","computed":[],"computed_en":[],"activity":"Ciepło spalania\nZakres:\nZakres (4000 – 33000) J/g\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna","reference":"PN-EN ISO 21654:2021-12","norm_bases":["PN-EN ISO 21654:2021-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady: kod 19 12 10, 19 12 12, 20 03 01, Ciepło spalania\nZakres:\nZakres (4000 – 33000) J/g\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna PN-EN ISO 21654:2021-12 Odpady: kod 19 12 10, 19 12 12, 20 03 01, Cieplo spalania\nZakres:\nZakres (4000 – 33000) J/g\nWartosc opalowa (z obliczen)\nMetoda kalorymetryczna PN-EN ISO 21654:2021-12","categories":["environment"],"row_index":44,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste: code 19 12 10, 19 12 12, 20 03 01, Gross calorific value Calorimetric method Range Net calorific value (calculated) PN-EN ISO 21654:2021-12","methodology_zh":"高位发热量","parameters_zh":[{"name":"范围","range":"(4000 – 33000) J/g"},{"name":"低位发热量（计算值）"}],"search_zh":"高位发热量 量热法 范围 低位发热量（计算值） PN-EN ISO 21654:2021-12","technique_zh":"量热法"},{"_id":"6a5dc9adf1c10c8ce825ad0c","lab_id":"69ad52a3de79e566650fb1bf","country":"PL","accr_number":"AB 325","accr_body":"PCA","test_object":"Odpady: kod 19 12 10, 19 12 12, 20 03 01,","test_object_en":"Waste: code 19 12 10, 19 12 12, 20 03 01,","methodology":"Zawartość siarki","methodology_en":"Sulfur content","parameters":[{"name":"Zakres","range":"(0,05 – 1,20) %"}],"parameters_en":[{"name":"Range","range":"(0,05 – 1,20) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"technique_en":"High-temperature combustion with IR detection","computed":[],"computed_en":[],"activity":"Zawartość siarki\nZakres (0,05 – 1,20) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN–EN 15408:2011","norm_bases":["PN–EN 15408:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady: kod 19 12 10, 19 12 12, 20 03 01, Zawartość siarki\nZakres (0,05 – 1,20) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN–EN 15408:2011 Odpady: kod 19 12 10, 19 12 12, 20 03 01, Zawartosc siarki\nZakres (0,05 – 1,20) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN–EN 15408:2011","categories":["environment"],"row_index":45,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste: code 19 12 10, 19 12 12, 20 03 01, Sulfur content High-temperature combustion with IR detection Range PN–EN 15408:2011","parameters_zh":[{"name":"范围","range":"(0,05 – 1,20) %"}],"search_zh":"硫含量 高温燃烧红外检测法 范围 PN–EN 15408:2011","technique_zh":"高温燃烧红外检测法","methodology_zh":"硫含量"},{"_id":"6a5dc9adf1c10c8ce825ad0d","lab_id":"69ad52a3de79e566650fb1bf","country":"PL","accr_number":"AB 325","accr_body":"PCA","test_object":"Odpady: kod 02 07 99, 03 03 07, 10 01 82 10 01 02, 10 02 08, 12 01 15 16 07 99, 19 05 01, 19 05 03 19 05 99, 19 10 04, 19 12 09","test_object_en":"Waste: code 02 07 99, 03 03 07, 10 01 82 10 01 02, 10 02 08, 12 01 15 16 07 99, 19 05 01, 19 05 03 19 05 99, 19 10 04, 19 12 09","methodology":"Stężenie i zawartość pierwiastków","methodology_en":"Element concentration and content","parameters":[{"name":"sód","range":"(1,00 – 2000) mg/l"},{"name":"Zakres","range":"(10,0 – 20000)mg/kg"},{"name":"cynk","range":"(0,005 – 100) mg/l"},{"name":"(0,050 – 1000) mg/kg"},{"name":"kadm","range":"(0,003 – 0,50) mg/l"},{"name":"(0,030 – 5,00) mg/kg"},{"name":"ołów","range":"(0,02 – 1,0) mg/l"},{"name":"(0,2 – 10) mg/kg"},{"name":"chrom","range":"(0,010 – 10,0) mg/l"},{"name":"(0,100 – 100) mg/kg"},{"name":"miedź","range":"(0,010 – 10,0) mg/l"},{"name":"(0,100 – 100) mg/kg"},{"name":"nikiel","range":"(0,010 – 10,0) mg/l"},{"name":"(0,100 – 100) mg/kg"},{"name":"bar","range":"(0,100 – 100) mg/l"},{"name":"(1,00 – 1000) mg/kg"},{"name":"molibden","range":"(0,100 – 10,0) mg/l"},{"name":"(1,00 – 100) mg/kg"}],"parameters_en":[{"name":"sodium","range":"(1,00 – 2000) mg/l"},{"name":"Range","range":"(10,0 – 20000)mg/kg"},{"name":"zinc","range":"(0,005 – 100) mg/l"},{"name":"(0,050 – 1000) mg/kg"},{"name":"cadmium","range":"(0,003 – 0,50) mg/l"},{"name":"(0,030 – 5,00) mg/kg"},{"name":"lead","range":"(0,02 – 1,0) mg/l"},{"name":"(0,2 – 10) mg/kg"},{"name":"chromium","range":"(0,010 – 10,0) mg/l"},{"name":"(0,100 – 100) mg/kg"},{"name":"copper","range":"(0,010 – 10,0) mg/l"},{"name":"(0,100 – 100) mg/kg"},{"name":"nickel","range":"(0,010 – 10,0) mg/l"},{"name":"(0,100 – 100) mg/kg"},{"name":"barium","range":"(0,100 – 100) mg/l"},{"name":"(1,00 – 1000) mg/kg"},{"name":"molybdenum","range":"(0,100 – 10,0) mg/l"},{"name":"(1,00 – 100) mg/kg"}],"technique":"Metoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","computed":[],"computed_en":[],"activity":"Stężenie i zawartość pierwiastków\nZakres:\nsód (1,00 – 2000) mg/l\nZakres (10,0 – 20000)mg/kg\ncynk (0,005 – 100) mg/l\n(0,050 – 1000) mg/kg\nkadm (0,003 – 0,50) mg/l\n(0,030 – 5,00) mg/kg\nołów (0,02 – 1,0) mg/l\n(0,2 – 10) mg/kg\nchrom (0,010 – 10,0) mg/l\n(0,100 – 100) mg/kg\nmiedź (0,010 – 10,0) mg/l\n(0,100 – 100) mg/kg\nnikiel (0,010 – 10,0) mg/l\n(0,100 – 100) mg/kg\nbar (0,100 – 100) mg/l\n(1,00 – 1000) mg/kg\nmolibden (0,100 – 10,0) mg/l\n(1,00 – 100) mg/kg\nMetoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009 | PN-EN 12457-2:2006","norm_bases":["PN-EN ISO 11885:2009","PN-EN 12457-2:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady: kod 02 07 99, 03 03 07, 10 01 82 10 01 02, 10 02 08, 12 01 15 16 07 99, 19 05 01, 19 05 03 19 05 99, 19 10 04, 19 12 09 Stężenie i zawartość pierwiastków\nZakres:\nsód (1,00 – 2000) mg/l\nZakres (10,0 – 20000)mg/kg\ncynk (0,005 – 100) mg/l\n(0,050 – 1000) mg/kg\nkadm (0,003 – 0,50) mg/l\n(0,030 – 5,00) mg/kg\nołów (0,02 – 1,0) mg/l\n(0,2 – 10) mg/kg\nchrom (0,010 – 10,0) mg/l\n(0,100 – 100) mg/kg\nmiedź (0,010 – 10,0) mg/l\n(0,100 – 100) mg/kg\nnikiel (0,010 – 10,0) mg/l\n(0,100 – 100) mg/kg\nbar (0,100 – 100) mg/l\n(1,00 – 1000) mg/kg\nmolibden (0,100 – 10,0) mg/l\n(1,00 – 100) mg/kg\nMetoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 | PN-EN 12457-2:2006 Odpady: kod 02 07 99, 03 03 07, 10 01 82 10 01 02, 10 02 08, 12 01 15 16 07 99, 19 05 01, 19 05 03 19 05 99, 19 10 04, 19 12 09 Stezenie i zawartosc pierwiastkow\nZakres:\nsod (1,00 – 2000) mg/l\nZakres (10,0 – 20000)mg/kg\ncynk (0,005 – 100) mg/l\n(0,050 – 1000) mg/kg\nkadm (0,003 – 0,50) mg/l\n(0,030 – 5,00) mg/kg\nolow (0,02 – 1,0) mg/l\n(0,2 – 10) mg/kg\nchrom (0,010 – 10,0) mg/l\n(0,100 – 100) mg/kg\nmiedz (0,010 – 10,0) mg/l\n(0,100 – 100) mg/kg\nnikiel (0,010 – 10,0) mg/l\n(0,100 – 100) mg/kg\nbar (0,100 – 100) mg/l\n(1,00 – 1000) mg/kg\nmolibden (0,100 – 10,0) mg/l\n(1,00 – 100) mg/kg\nMetoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009 | PN-EN 12457-2:2006","categories":["environment","materials"],"row_index":46,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste: code 02 07 99, 03 03 07, 10 01 82 10 01 02, 10 02 08, 12 01 15 16 07 99, 19 05 01, 19 05 03 19 05 99, 19 10 04, 19 12 09 Element concentration and content Inductively coupled plasma optical emission spectrometry (ICP-OES) sodium Range zinc (0,050 – 1000) mg/kg cadmium (0,030 – 5,00) mg/kg lead (0,2 – 10) mg/kg chromium (0,100 – 100) mg/kg copper (0,100 – 100) mg/kg nickel (0,100 – 100) mg/kg barium (1,00 – 1000) mg/kg molybdenum (1,00 – 100) mg/kg PN-EN ISO 11885:2009 | PN-EN 12457-2:2006","parameters_zh":[{"name":"钠","range":"(1,00 – 2000) mg/l"},{"name":"范围","range":"(10,0 – 20000)mg/kg"},{"name":"锌","range":"(0,005 – 100) mg/l"},{"name":"(0,050 – 1000) mg/kg"},{"name":"镉","range":"(0,003 – 0,50) mg/l"},{"name":"(0,030 – 5,00) mg/kg"},{"name":"铅","range":"(0,02 – 1,0) mg/l"},{"name":"(0,2 – 10) mg/kg"},{"name":"铬","range":"(0,010 – 10,0) mg/l"},{"name":"(0,100 – 100) mg/kg"},{"name":"铜","range":"(0,010 – 10,0) mg/l"},{"name":"(0,100 – 100) mg/kg"},{"name":"镍","range":"(0,010 – 10,0) mg/l"},{"name":"(0,100 – 100) mg/kg"},{"name":"钡","range":"(0,100 – 100) mg/l"},{"name":"(1,00 – 1000) mg/kg"},{"name":"钼","range":"(0,100 – 10,0) mg/l"},{"name":"(1,00 – 100) mg/kg"}],"search_zh":"元素的浓度与含量 电感耦合等离子体发射光谱法（ICP-OES） 钠 范围 锌 镉 铅 铬 铜 镍 钡 钼 PN-EN ISO 11885:2009 | PN-EN 12457-2:2006","technique_zh":"电感耦合等离子体发射光谱法（ICP-OES）","methodology_zh":"元素的浓度与含量"},{"_id":"6a5dc9adf1c10c8ce825ad0e","lab_id":"69ad52a3de79e566650fb1bf","country":"PL","accr_number":"AB 325","accr_body":"PCA","test_object":"Odpady: kod 02 07 99, 03 03 07, 10 01 82 10 01 02, 10 02 08, 12 01 15 16 07 99, 19 05 01, 19 05 03 19 05 99, 19 10 04, 19 12 09","test_object_en":"Waste: code 02 07 99, 03 03 07, 10 01 82 10 01 02, 10 02 08, 12 01 15 16 07 99, 19 05 01, 19 05 03 19 05 99, 19 10 04, 19 12 09","methodology":"Stężenie i zawartość rtęci","methodology_en":"Mercury concentration and content","parameters":[{"name":"Zakres","range":"(1,0 – 20) μg/l"},{"name":"Zakres","range":"(0,01 – 0,20) mg/kg"}],"parameters_en":[{"name":"Range","range":"(1,0 – 20) μg/l"},{"name":"Range","range":"(0,01 – 0,20) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)"],"technique_en":"Cold vapour atomic absorption spectrometry (CVAAS)","computed":[],"computed_en":[],"activity":"Stężenie i zawartość rtęci\nZakres:\nZakres (1,0 – 20) μg/l\nZakres (0,01 – 0,20) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"PB-19, wydanie 2 z dnia 30.08.2017 r. | PN-EN 12457-2:2006","norm_bases":["PB-19, wydanie 2 z dnia 30.08.2017 r.","PN-EN 12457-2:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady: kod 02 07 99, 03 03 07, 10 01 82 10 01 02, 10 02 08, 12 01 15 16 07 99, 19 05 01, 19 05 03 19 05 99, 19 10 04, 19 12 09 Stężenie i zawartość rtęci\nZakres:\nZakres (1,0 – 20) μg/l\nZakres (0,01 – 0,20) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PB-19, wydanie 2 z dnia 30.08.2017 r. | PN-EN 12457-2:2006 Odpady: kod 02 07 99, 03 03 07, 10 01 82 10 01 02, 10 02 08, 12 01 15 16 07 99, 19 05 01, 19 05 03 19 05 99, 19 10 04, 19 12 09 Stezenie i zawartosc rteci\nZakres:\nZakres (1,0 – 20) μg/l\nZakres (0,01 – 0,20) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PB-19, wydanie 2 z dnia 30.08.2017 r. | PN-EN 12457-2:2006","categories":["environment"],"row_index":47,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste: code 02 07 99, 03 03 07, 10 01 82 10 01 02, 10 02 08, 12 01 15 16 07 99, 19 05 01, 19 05 03 19 05 99, 19 10 04, 19 12 09 Mercury concentration and content Cold vapour atomic absorption spectrometry (CVAAS) Range Range PB-19, wydanie 2 z dnia 30.08.2017 r. | PN-EN 12457-2:2006","parameters_zh":[{"name":"范围","range":"(1,0 – 20) μg/l"},{"name":"范围","range":"(0,01 – 0,20) mg/kg"}],"search_zh":"汞的浓度与含量 冷蒸气原子吸收光谱法（CVAAS） 范围 范围 PB-19, wydanie 2 z dnia 30.08.2017 r. | PN-EN 12457-2:2006","technique_zh":"冷蒸气原子吸收光谱法（CVAAS）","methodology_zh":"汞的浓度与含量"},{"_id":"6a5dc9adf1c10c8ce825ad0f","lab_id":"69ad52a3de79e566650fb1bf","country":"PL","accr_number":"AB 325","accr_body":"PCA","test_object":"Odpady: kod 02 07 99, 03 03 07, 10 01 82 10 01 02, 10 02 08, 12 01 15 16 07 99, 19 05 01, 19 05 03 19 05 99, 19 10 04, 19 12 09","test_object_en":"Waste: code 02 07 99, 03 03 07, 10 01 82 10 01 02, 10 02 08, 12 01 15 16 07 99, 19 05 01, 19 05 03 19 05 99, 19 10 04, 19 12 09","methodology":"Stężenie i zawartość arsenu","methodology_en":"Arsenic concentration and content","parameters":[{"name":"Zakres","range":"(0,50 – 40) μg/l"},{"name":"Zakres","range":"(0,005 – 0,40) mg/kg"}],"parameters_en":[{"name":"Range","range":"(0,50 – 40) μg/l"},{"name":"Range","range":"(0,005 – 0,40) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem wodorków (HGAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem wodorków (HGAAS)"],"technique_en":"Hydride generation atomic absorption spectrometry (HGAAS)","computed":[],"computed_en":[],"activity":"Stężenie i zawartość arsenu\nZakres:\nZakres (0,50 – 40) μg/l\nZakres (0,005 – 0,40) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem wodorków (HGAAS)","reference":"PB-05/4, wydanie 5 z dnia 30.08.2017 r. | PN-EN 12457-2:2006","norm_bases":["PB-05/4, wydanie 5 z dnia 30.08.2017 r.","PN-EN 12457-2:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady: kod 02 07 99, 03 03 07, 10 01 82 10 01 02, 10 02 08, 12 01 15 16 07 99, 19 05 01, 19 05 03 19 05 99, 19 10 04, 19 12 09 Stężenie i zawartość arsenu\nZakres:\nZakres (0,50 – 40) μg/l\nZakres (0,005 – 0,40) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem wodorków (HGAAS) PB-05/4, wydanie 5 z dnia 30.08.2017 r. | PN-EN 12457-2:2006 Odpady: kod 02 07 99, 03 03 07, 10 01 82 10 01 02, 10 02 08, 12 01 15 16 07 99, 19 05 01, 19 05 03 19 05 99, 19 10 04, 19 12 09 Stezenie i zawartosc arsenu\nZakres:\nZakres (0,50 – 40) μg/l\nZakres (0,005 – 0,40) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem wodorkow (HGAAS) PB-05/4, wydanie 5 z dnia 30.08.2017 r. | PN-EN 12457-2:2006","categories":["environment"],"row_index":48,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste: code 02 07 99, 03 03 07, 10 01 82 10 01 02, 10 02 08, 12 01 15 16 07 99, 19 05 01, 19 05 03 19 05 99, 19 10 04, 19 12 09 Arsenic concentration and content Hydride generation atomic absorption spectrometry (HGAAS) Range Range PB-05/4, wydanie 5 z dnia 30.08.2017 r. | PN-EN 12457-2:2006","parameters_zh":[{"name":"范围","range":"(0,50 – 40) μg/l"},{"name":"范围","range":"(0,005 – 0,40) mg/kg"}],"search_zh":"氢化物发生原子吸收光谱法（HGAAS） 范围 范围 PB-05/4, wydanie 5 z dnia 30.08.2017 r. | PN-EN 12457-2:2006","technique_zh":"氢化物发生原子吸收光谱法（HGAAS）"},{"_id":"6a5dc9adf1c10c8ce825ad10","lab_id":"69ad52a3de79e566650fb1bf","country":"PL","accr_number":"AB 325","accr_body":"PCA","test_object":"Paliwa stałe: Stałe paliwa wtórne","test_object_en":"Solid fuels: Solid recovered fuels","methodology":"Zawartość chloru","methodology_en":"Chlorine content","parameters":[{"name":"chlor","range":"(0,050 – 3,000) %"}],"parameters_en":[{"name":"chlorine","range":"(0,050 – 3,000) %"}],"technique":"Metoda turbidymetryczna","techniques":["Metoda turbidymetryczna"],"technique_en":"Turbidimetric method","computed":[],"computed_en":[],"activity":"Zawartość chloru\nchlor (0,050 – 3,000) %\nMetoda turbidymetryczna","reference":"PN-EN 14582:2017-02","norm_bases":["PN-EN 14582:2017-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: Stałe paliwa wtórne Zawartość chloru\nchlor (0,050 – 3,000) %\nMetoda turbidymetryczna PN-EN 14582:2017-02 Paliwa stale: Stale paliwa wtorne Zawartosc chloru\nchlor (0,050 – 3,000) %\nMetoda turbidymetryczna PN-EN 14582:2017-02","categories":["petro"],"row_index":49,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: Solid recovered fuels Chlorine content Turbidimetric method chlorine PN-EN 14582:2017-02","methodology_zh":"氯含量","search_zh":"固体燃料：固体再生燃料 氯含量 浊度法 PN-EN 14582:2017-02","technique_zh":"浊度法","test_object_zh":"固体燃料：固体再生燃料"},{"_id":"6a5dc9adf1c10c8ce825ad11","lab_id":"69ad52a3de79e566650fb1bf","country":"PL","accr_number":"AB 325","accr_body":"PCA","test_object":"Paliwa stałe: Stałe paliwa wtórne","test_object_en":"Solid fuels: Solid recovered fuels","methodology":"Zawartość frakcji biodegradowalnej","methodology_en":"Biodegradable fraction content","parameters":[{"name":"udział masowy biomasy z zastosowaniem selektywnego rozpuszczania"},{"name":"Zakres","range":"(5,00 – 99,0) %"},{"name":"Zawartość frakcji niebiodegradowalnej"},{"name":"udział masowy niebiomasy (z obliczeń)"}],"parameters_en":[{"name":"mass fraction of biomass using selective dissolution"},{"name":"Range","range":"(5,00 – 99,0) %"},{"name":"Content of the non-biodegradable fraction"},{"name":"mass fraction of non-biomass (calculated)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość frakcji biodegradowalnej\nZakres:\nudział masowy biomasy z zastosowaniem selektywnego rozpuszczania\nZakres (5,00 – 99,0) %\nZawartość frakcji niebiodegradowalnej\nudział masowy niebiomasy (z obliczeń)\nMetoda wagowa","reference":"PN-EN ISO 21644:2021-07","norm_bases":["PN-EN ISO 21644:2021-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: Stałe paliwa wtórne Zawartość frakcji biodegradowalnej\nZakres:\nudział masowy biomasy z zastosowaniem selektywnego rozpuszczania\nZakres (5,00 – 99,0) %\nZawartość frakcji niebiodegradowalnej\nudział masowy niebiomasy (z obliczeń)\nMetoda wagowa PN-EN ISO 21644:2021-07 Paliwa stale: Stale paliwa wtorne Zawartosc frakcji biodegradowalnej\nZakres:\nudzial masowy biomasy z zastosowaniem selektywnego rozpuszczania\nZakres (5,00 – 99,0) %\nZawartosc frakcji niebiodegradowalnej\nudzial masowy niebiomasy (z obliczen)\nMetoda wagowa PN-EN ISO 21644:2021-07","categories":["petro"],"row_index":50,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: Solid recovered fuels Biodegradable fraction content Gravimetric method mass fraction of biomass using selective dissolution Range Content of the non-biodegradable fraction mass fraction of non-biomass (calculated) PN-EN ISO 21644:2021-07","parameters_zh":[{"name":"采用选择性溶解法测定的生物质质量分数"},{"name":"范围","range":"(5,00 – 99,0) %"},{"name":"不可生物降解组分含量"},{"name":"非生物质质量分数（由计算得出）"}],"search_zh":"固体燃料：固体再生燃料 可生物降解组分含量 重量法 采用选择性溶解法测定的生物质质量分数 范围 不可生物降解组分含量 非生物质质量分数（由计算得出） PN-EN ISO 21644:2021-07","technique_zh":"重量法","test_object_zh":"固体燃料：固体再生燃料","methodology_zh":"可生物降解组分含量"},{"_id":"6a5dc9adf1c10c8ce825ad12","lab_id":"69ad52a3de79e566650fb1bf","country":"PL","accr_number":"AB 325","accr_body":"PCA","test_object":"Paliwa stałe: Stałe paliwa wtórne","test_object_en":"Solid fuels: Solid recovered fuels","methodology":"Zawartość wilgoci całkowitej","methodology_en":"Total moisture content","parameters":[{"name":"Zakres","range":"(1,0 – 80,0) %"}],"parameters_en":[{"name":"Range","range":"(1,0 – 80,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość wilgoci całkowitej\nZakres (1,0 – 80,0) %\nMetoda wagowa","reference":"SIST–TSCEN/TS 15414–1:2010","norm_bases":["SIST–TSCEN/TS 15414–1:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: Stałe paliwa wtórne Zawartość wilgoci całkowitej\nZakres (1,0 – 80,0) %\nMetoda wagowa SIST–TSCEN/TS 15414–1:2010 Paliwa stale: Stale paliwa wtorne Zawartosc wilgoci calkowitej\nZakres (1,0 – 80,0) %\nMetoda wagowa SIST–TSCEN/TS 15414–1:2010","categories":["petro"],"row_index":51,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: Solid recovered fuels Total moisture content Gravimetric method Range SIST–TSCEN/TS 15414–1:2010","methodology_zh":"全水分含量","parameters_zh":[{"name":"范围","range":"(1,0 – 80,0) %"}],"search_zh":"固体燃料：固体再生燃料 全水分含量 重量法 范围 SIST–TSCEN/TS 15414–1:2010","technique_zh":"重量法","test_object_zh":"固体燃料：固体再生燃料"},{"_id":"6a5dc9adf1c10c8ce825ad13","lab_id":"69ad52a3de79e566650fb1bf","country":"PL","accr_number":"AB 325","accr_body":"PCA","test_object":"Paliwa stałe: Stałe paliwa wtórne","test_object_en":"Solid fuels: Solid recovered fuels","methodology":"Zawartość wilgoci w ogólnej próbce analitycznej","methodology_en":"Moisture content in the general analytical sample","parameters":[{"name":"Zakres","range":"(0,10 – 5,0) %"}],"parameters_en":[{"name":"Range","range":"(0,10 – 5,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość wilgoci w ogólnej próbce analitycznej\nZakres (0,10 – 5,0) %\nMetoda wagowa","reference":"PN-EN ISO 21660-3:2021-08","norm_bases":["PN-EN ISO 21660-3:2021-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: Stałe paliwa wtórne Zawartość wilgoci w ogólnej próbce analitycznej\nZakres (0,10 – 5,0) %\nMetoda wagowa PN-EN ISO 21660-3:2021-08 Paliwa stale: Stale paliwa wtorne Zawartosc wilgoci w ogolnej probce analitycznej\nZakres (0,10 – 5,0) %\nMetoda wagowa PN-EN ISO 21660-3:2021-08","categories":["petro"],"row_index":52,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: Solid recovered fuels Moisture content in the general analytical sample Gravimetric method Range PN-EN ISO 21660-3:2021-08","parameters_zh":[{"name":"范围","range":"(0,10 – 5,0) %"}],"search_zh":"固体燃料：固体再生燃料 总分析样品中的水分含量 重量法 范围 PN-EN ISO 21660-3:2021-08","technique_zh":"重量法","test_object_zh":"固体燃料：固体再生燃料","methodology_zh":"总分析样品中的水分含量"},{"_id":"6a5dc9adf1c10c8ce825ad14","lab_id":"69ad52a3de79e566650fb1bf","country":"PL","accr_number":"AB 325","accr_body":"PCA","test_object":"Paliwa stałe: Stałe paliwa wtórne","test_object_en":"Solid fuels: Solid recovered fuels","methodology":"Zawartość popiołu","methodology_en":"Ash content","parameters":[{"name":"Zakres","range":"(0,90 – 83,0) %"}],"parameters_en":[{"name":"Range","range":"(0,90 – 83,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość popiołu\nZakres (0,90 – 83,0) %\nMetoda wagowa","reference":"PN-EN ISO 21656:2021-08","norm_bases":["PN-EN ISO 21656:2021-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: Stałe paliwa wtórne Zawartość popiołu\nZakres (0,90 – 83,0) %\nMetoda wagowa PN-EN ISO 21656:2021-08 Paliwa stale: Stale paliwa wtorne Zawartosc popiolu\nZakres (0,90 – 83,0) %\nMetoda wagowa PN-EN ISO 21656:2021-08","categories":["petro"],"row_index":53,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: Solid recovered fuels Ash content Gravimetric method Range PN-EN ISO 21656:2021-08","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(0,90 – 83,0) %"}],"search_zh":"固体燃料：固体再生燃料 灰分含量 重量法 范围 PN-EN ISO 21656:2021-08","technique_zh":"重量法","test_object_zh":"固体燃料：固体再生燃料"},{"_id":"6a5dc9adf1c10c8ce825ad15","lab_id":"69ad52a3de79e566650fb1bf","country":"PL","accr_number":"AB 325","accr_body":"PCA","test_object":"Paliwa stałe: Stałe paliwa wtórne","test_object_en":"Solid fuels: Solid recovered fuels","methodology":"Zawartość rtęci","methodology_en":"Mercury content","parameters":[{"name":"Zakres","range":"(0,1 – 6,0) mg/kg"}],"parameters_en":[{"name":"Range","range":"(0,1 – 6,0) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","techniques":["Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji"],"technique_en":"Atomic absorption spectrometry with amalgamation technique","computed":[],"computed_en":[],"activity":"Zawartość rtęci\nZakres (0,1 – 6,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","reference":"PB-21, wydanie 3 z dnia 30.08.2017 r.","norm_bases":["PB-21, wydanie 3 z dnia 30.08.2017 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: Stałe paliwa wtórne Zawartość rtęci\nZakres (0,1 – 6,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji PB-21, wydanie 3 z dnia 30.08.2017 r. Paliwa stale: Stale paliwa wtorne Zawartosc rteci\nZakres (0,1 – 6,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z technika amalgamacji PB-21, wydanie 3 z dnia 30.08.2017 r.","categories":["petro"],"row_index":54,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: Solid recovered fuels Mercury content Atomic absorption spectrometry with amalgamation technique Range PB-21, wydanie 3 z dnia 30.08.2017 r.","methodology_zh":"汞含量","parameters_zh":[{"name":"范围","range":"(0,1 – 6,0) mg/kg"}],"search_zh":"固体燃料：固体再生燃料 汞含量 原子吸收光谱法（汞齐化技术） 范围 PB-21, wydanie 3 z dnia 30.08.2017 r.","technique_zh":"原子吸收光谱法（汞齐化技术）","test_object_zh":"固体燃料：固体再生燃料"},{"_id":"6a5dc9adf1c10c8ce825ad16","lab_id":"69ad52a3de79e566650fb1bf","country":"PL","accr_number":"AB 325","accr_body":"PCA","test_object":"Paliwa stałe: Stałe paliwa wtórne","test_object_en":"Solid fuels: Solid recovered fuels","methodology":"Zawartość wodoru i węgla:","methodology_en":"Hydrogen and carbon content:","parameters":[{"name":"Wodór","range":"(4,00 – 11,00) %"},{"name":"Węgiel","range":"(35,0 – 70,0) %"}],"parameters_en":[{"name":"Hydrogen","range":"(4,00 – 11,00) %"},{"name":"Carbon","range":"(35,0 – 70,0) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"technique_en":"High-temperature combustion with IR detection","computed":[],"computed_en":[],"activity":"Zawartość wodoru i węgla:\nZakres:\nWodór (4,00 – 11,00) %\nWęgiel (35,0 – 70,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN ISO 21663:2021-06","norm_bases":["PN-EN ISO 21663:2021-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: Stałe paliwa wtórne Zawartość wodoru i węgla:\nZakres:\nWodór (4,00 – 11,00) %\nWęgiel (35,0 – 70,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN ISO 21663:2021-06 Paliwa stale: Stale paliwa wtorne Zawartosc wodoru i wegla:\nZakres:\nWodor (4,00 – 11,00) %\nWegiel (35,0 – 70,0) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN ISO 21663:2021-06","categories":["petro"],"row_index":55,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: Solid recovered fuels Hydrogen and carbon content: High-temperature combustion with IR detection Hydrogen Carbon PN-EN ISO 21663:2021-06","search_zh":"固体燃料：固体再生燃料 高温燃烧红外检测法 氢 碳 PN-EN ISO 21663:2021-06","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：固体再生燃料","parameters_zh":[{"name":"氢","range":"(4,00 – 11,00) %"},{"name":"碳","range":"(35,0 – 70,0) %"}]},{"_id":"6a5dc9adf1c10c8ce825ad17","lab_id":"69ad52a3de79e566650fb1bf","country":"PL","accr_number":"AB 325","accr_body":"PCA","test_object":"Paliwa stałe: Stałe paliwa wtórne","test_object_en":"Solid fuels: Solid recovered fuels","methodology":"Ciepło spalania","methodology_en":"Gross calorific value","parameters":[{"name":"Zakres","range":"(4000 – 33000) J/g"},{"name":"Wartość opałowa (z obliczeń)"}],"parameters_en":[{"name":"Range","range":"(4000 – 33000) J/g"},{"name":"Net calorific value (calculated)"}],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna"],"technique_en":"Calorimetric method","computed":[],"computed_en":[],"activity":"Ciepło spalania\nZakres:\nZakres (4000 – 33000) J/g\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna","reference":"PN-EN ISO 21654:2021-12","norm_bases":["PN-EN ISO 21654:2021-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: Stałe paliwa wtórne Ciepło spalania\nZakres:\nZakres (4000 – 33000) J/g\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna PN-EN ISO 21654:2021-12 Paliwa stale: Stale paliwa wtorne Cieplo spalania\nZakres:\nZakres (4000 – 33000) J/g\nWartosc opalowa (z obliczen)\nMetoda kalorymetryczna PN-EN ISO 21654:2021-12","categories":["petro"],"row_index":56,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: Solid recovered fuels Gross calorific value Calorimetric method Range Net calorific value (calculated) PN-EN ISO 21654:2021-12","methodology_zh":"高位发热量","parameters_zh":[{"name":"范围","range":"(4000 – 33000) J/g"},{"name":"低位发热量（计算值）"}],"search_zh":"固体燃料：固体再生燃料 高位发热量 量热法 范围 低位发热量（计算值） PN-EN ISO 21654:2021-12","technique_zh":"量热法","test_object_zh":"固体燃料：固体再生燃料"},{"_id":"6a5dc9adf1c10c8ce825ad18","lab_id":"69ad52a3de79e566650fb1bf","country":"PL","accr_number":"AB 325","accr_body":"PCA","test_object":"Paliwa stałe: Stałe paliwa wtórne","test_object_en":"Solid fuels: Solid recovered fuels","methodology":"Zawartość siarki","methodology_en":"Sulfur content","parameters":[{"name":"Zakres","range":"(0,05 – 1,20) %"}],"parameters_en":[{"name":"Range","range":"(0,05 – 1,20) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"technique_en":"High-temperature combustion with IR detection","computed":[],"computed_en":[],"activity":"Zawartość siarki\nZakres (0,05 – 1,20) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN 15408:2011","norm_bases":["PN-EN 15408:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: Stałe paliwa wtórne Zawartość siarki\nZakres (0,05 – 1,20) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN 15408:2011 Paliwa stale: Stale paliwa wtorne Zawartosc siarki\nZakres (0,05 – 1,20) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN 15408:2011","categories":["petro"],"row_index":57,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: Solid recovered fuels Sulfur content High-temperature combustion with IR detection Range PN-EN 15408:2011","parameters_zh":[{"name":"范围","range":"(0,05 – 1,20) %"}],"search_zh":"固体燃料：固体再生燃料 硫含量 高温燃烧红外检测法 范围 PN-EN 15408:2011","technique_zh":"高温燃烧红外检测法","methodology_zh":"硫含量","test_object_zh":"固体燃料：固体再生燃料"},{"_id":"6a5dc9adf1c10c8ce825ad19","lab_id":"69ad52a3de79e566650fb1bf","country":"PL","accr_number":"AB 325","accr_body":"PCA","test_object":"Środowisko ogólne - hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych.","test_object_en":"General environment - noise from installations, equipment and industrial plants.","methodology":"Równoważny poziom dźwięku A","methodology_en":"A-weighted equivalent sound pressure level","parameters":[{"name":"Zakres","range":"(22 - 136) dB"}],"parameters_en":[{"name":"Range","range":"(22 - 136) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A\nZakres (22 - 136) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz.U. 2023 poz. 1706) z wyłączeniem punktu F","norm_bases":["Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz.U. 2023 poz. 1706) z wyłączeniem punktu F"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne - hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych. Równoważny poziom dźwięku A\nZakres (22 - 136) dB\nMetoda pomiarowa bezpośrednia Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz.U. 2023 poz. 1706) z wyłączeniem punktu F Srodowisko ogolne - halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych. Rownowazny poziom dzwieku A\nZakres (22 - 136) dB\nMetoda pomiarowa bezposrednia Zalacznik Nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (tj. Dz.U. 2023 poz. 1706) z wylaczeniem punktu F","categories":["environment"],"row_index":58,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"General environment - noise from installations, equipment and industrial plants. A-weighted equivalent sound pressure level Direct measurement method Range Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz.U. 2023 poz. 1706) z wyłączeniem punktu F","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"范围","range":"(22 - 136) dB"}],"search_zh":"A 计权等效声级 直接测量法 范围 Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz.U. 2023 poz. 1706) z wyłączeniem punktu F","technique_zh":"直接测量法"},{"_id":"6a5dc9adf1c10c8ce825ad1a","lab_id":"69ad52a3de79e566650fb1bf","country":"PL","accr_number":"AB 325","accr_body":"PCA","test_object":"Środowisko ogólne - hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych.","test_object_en":"General environment - noise from installations, equipment and industrial plants.","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami, LAeqD i LAeqN (z obliczeń)","methodology_en":"A-weighted equivalent sound level over the reference time T expressed by the indicators, LAeqD and LAeqN (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami, LAeqD i LAeqN (z obliczeń)","reference":"Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz.U. 2023 poz. 1706) z wyłączeniem punktu F","norm_bases":["Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz.U. 2023 poz. 1706) z wyłączeniem punktu F"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne - hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych. Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami, LAeqD i LAeqN (z obliczeń) Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz.U. 2023 poz. 1706) z wyłączeniem punktu F Srodowisko ogolne - halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych. Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami, LAeqD i LAeqN (z obliczen) Zalacznik Nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (tj. Dz.U. 2023 poz. 1706) z wylaczeniem punktu F","categories":["environment"],"row_index":59,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"General environment - noise from installations, equipment and industrial plants. A-weighted equivalent sound level over the reference time T expressed by the indicators, LAeqD and LAeqN (calculated) Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz.U. 2023 poz. 1706) z wyłączeniem punktu F"}],"has_pdf":true}