{"lab":{"_id":"69ad52a3de79e566650fb1bd","accr_number":"AB 324","country":"PL","accr_body":"PCA","address":"ZAKŁAD WIELKICH MOCY, ul. Mory 8, 01-330 Warszawa, INSTITUTE OF POWER ENGINEERING – NATIONAL RESEARCH","categories":["construction","materials"],"city":"Warszawa","imported_at":"2026-03-08T10:42:43.265Z","methods_count":165,"name":"INSTYTUT ENERGETYKI – PAŃSTWOWY INSTYTUT BADAWCZY","parse_status":"parsed","parse_version":3,"pdf_files":["AB_324.pdf"],"scope_summary":"","search_text":"instytut energetyki – państwowy instytut badawczy zakład wielkich mocy, ul. mory 8, 01-330 warszawa, institute of power engineering – national research pharma electronics other metrology environment construction water materials food","status":"active","updated_at":"2026-03-08T14:51:10.440Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:10.440Z","location":{"type":"Point","coordinates":[21.0122,52.2297]},"email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20324,podmiot.html","fields_of_testing":[{"codes":"J/6","pl":"Badania mechaniczne wyrobów i wyposażenia elektrycznego","en":"Mechanical tests of electrical products and equipment"},{"codes":"E/6;E19","pl":"Badania elektryczne i elektroniczne wyrobów i wyposażenia elektrycznego, środków ochrony osobistej","en":"Electric and electronic tests of electrical products and equipment, personal protection equipment"}],"issue":{"no":"30","date":"13.02.2026"},"parse_date":"2026-07-20T07:09:33.746Z","parse_source":"script-pdfplumber","map_coord":[52.212121,20.876809],"map_geo":"nominatim-street","has_en":true,"category_counts":{"other":138,"construction":17,"materials":13},"category_scores":{"other":113.36,"construction":1.72,"materials":1.01},"has_zh":true},"methods":[{"_id":"6a5dc9adf1c10c8ce825ac3a","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Izolatory i łańcuchy izolatorów dla linii o Un = (1 - 400) kV","test_object_en":"Insulators and insulator strings for lines with Un = (1 - 400) kV","methodology":"Wytrzymałość elektryczna przy napięciu udarowym:","methodology_en":"Dielectric strength at impulse voltage:","parameters":[{"name":"piorunowym do Up = 4500 kV"},{"name":"łączeniowym do Up = 2800 kV"}],"parameters_en":[{"name":"lightning up to Up = 4500 kV"},{"name":"switching up to Up = 2800 kV"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość elektryczna przy napięciu udarowym:\nZakres:\npiorunowym do Up = 4500 kV\nłączeniowym do Up = 2800 kV","reference":"PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN IEC 60383-1:2024-04 | IEC 60383-1:2023 | PN-IEC 383-2:1997 | PN-IEC 383-2:1997/Ap1:2002 | IEC 60383-2:1993 | PN-EN 61109:2010 | IEC 61109:2025 | PN-EN 60137:2018-02 | PN-EN 60137:2018-02/AC:2018-10 | IEC 60137:2017 | IEC 60137:2017/COR1:2018 | PN-EN 60137:2018-02/AC:2018-10 | PN-EN 60168:1999 | PN-EN 60168:1999/A2:2002 | IEC 60168:1994+AMD1:1997 +AMD2:2000 CSV | PN-EN 60660:2002 | IEC 60660:1999 | PN-EN 50386:2010 | PN-EN 50386:2010/A1:2014 | PN-IEC 60720:2003 | IEC 60720:1981 | PN-EN IEC 60305:2021-10 | IEC 60305:2021 | PN-EN 61211:2005 | IEC 61211:2004 | PN-EN 61952:2010 | IEC 61952:2008 | PN-EN 62217:2013-06 | IEC 62217:2025 | PN-EN 62231:2008 | IEC 62231:2006","norm_bases":["PN-EN 60060-1:2011","IEC 60060-1:2025","PN-EN 60060-2:2011","IEC 60060-2:2025","PN-EN IEC 60383-1:2024-04","IEC 60383-1:2023","PN-IEC 383-2:1997","PN-IEC 383-2:1997/Ap1:2002","IEC 60383-2:1993","PN-EN 61109:2010","IEC 61109:2025","PN-EN 60137:2018-02","PN-EN 60137:2018-02/AC:2018-10","IEC 60137:2017","IEC 60137:2017/COR1:2018","PN-EN 60137:2018-02/AC:2018-10","PN-EN 60168:1999","PN-EN 60168:1999/A2:2002","IEC 60168:1994+AMD1:1997 +AMD2:2000 CSV","PN-EN 60660:2002","IEC 60660:1999","PN-EN 50386:2010","PN-EN 50386:2010/A1:2014","PN-IEC 60720:2003","IEC 60720:1981","PN-EN IEC 60305:2021-10","IEC 60305:2021","PN-EN 61211:2005","IEC 61211:2004","PN-EN 61952:2010","IEC 61952:2008","PN-EN 62217:2013-06","IEC 62217:2025","PN-EN 62231:2008","IEC 62231:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Izolatory i łańcuchy izolatorów dla linii o Un = (1 - 400) kV Wytrzymałość elektryczna przy napięciu udarowym:\nZakres:\npiorunowym do Up = 4500 kV\nłączeniowym do Up = 2800 kV PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN IEC 60383-1:2024-04 | IEC 60383-1:2023 | PN-IEC 383-2:1997 | PN-IEC 383-2:1997/Ap1:2002 | IEC 60383-2:1993 | PN-EN 61109:2010 | IEC 61109:2025 | PN-EN 60137:2018-02 | PN-EN 60137:2018-02/AC:2018-10 | IEC 60137:2017 | IEC 60137:2017/COR1:2018 | PN-EN 60137:2018-02/AC:2018-10 | PN-EN 60168:1999 | PN-EN 60168:1999/A2:2002 | IEC 60168:1994+AMD1:1997 +AMD2:2000 CSV | PN-EN 60660:2002 | IEC 60660:1999 | PN-EN 50386:2010 | PN-EN 50386:2010/A1:2014 | PN-IEC 60720:2003 | IEC 60720:1981 | PN-EN IEC 60305:2021-10 | IEC 60305:2021 | PN-EN 61211:2005 | IEC 61211:2004 | PN-EN 61952:2010 | IEC 61952:2008 | PN-EN 62217:2013-06 | IEC 62217:2025 | PN-EN 62231:2008 | IEC 62231:2006 Izolatory i lancuchy izolatorow dla linii o Un = (1 - 400) kV Wytrzymalosc elektryczna przy napieciu udarowym:\nZakres:\npiorunowym do Up = 4500 kV\nlaczeniowym do Up = 2800 kV PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN IEC 60383-1:2024-04 | IEC 60383-1:2023 | PN-IEC 383-2:1997 | PN-IEC 383-2:1997/Ap1:2002 | IEC 60383-2:1993 | PN-EN 61109:2010 | IEC 61109:2025 | PN-EN 60137:2018-02 | PN-EN 60137:2018-02/AC:2018-10 | IEC 60137:2017 | IEC 60137:2017/COR1:2018 | PN-EN 60137:2018-02/AC:2018-10 | PN-EN 60168:1999 | PN-EN 60168:1999/A2:2002 | IEC 60168:1994+AMD1:1997 +AMD2:2000 CSV | PN-EN 60660:2002 | IEC 60660:1999 | PN-EN 50386:2010 | PN-EN 50386:2010/A1:2014 | PN-IEC 60720:2003 | IEC 60720:1981 | PN-EN IEC 60305:2021-10 | IEC 60305:2021 | PN-EN 61211:2005 | IEC 61211:2004 | PN-EN 61952:2010 | IEC 61952:2008 | PN-EN 62217:2013-06 | IEC 62217:2025 | PN-EN 62231:2008 | IEC 62231:2006","categories":["other"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Insulators and insulator strings for lines with Un = (1 - 400) kV Dielectric strength at impulse voltage: lightning up to Up = 4500 kV switching up to Up = 2800 kV PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN IEC 60383-1:2024-04 | IEC 60383-1:2023 | PN-IEC 383-2:1997 | PN-IEC 383-2:1997/Ap1:2002 | IEC 60383-2:1993 | PN-EN 61109:2010 | IEC 61109:2025 | PN-EN 60137:2018-02 | PN-EN 60137:2018-02/AC:2018-10 | IEC 60137:2017 | IEC 60137:2017/COR1:2018 | PN-EN 60137:2018-02/AC:2018-10 | PN-EN 60168:1999 | PN-EN 60168:1999/A2:2002 | IEC 60168:1994+AMD1:1997 +AMD2:2000 CSV | PN-EN 60660:2002 | IEC 60660:1999 | PN-EN 50386:2010 | PN-EN 50386:2010/A1:2014 | PN-IEC 60720:2003 | IEC 60720:1981 | PN-EN IEC 60305:2021-10 | IEC 60305:2021 | PN-EN 61211:2005 | IEC 61211:2004 | PN-EN 61952:2010 | IEC 61952:2008 | PN-EN 62217:2013-06 | IEC 62217:2025 | PN-EN 62231:2008 | IEC 62231:2006","methodology_zh":"冲击电压下的介电强度：","parameters_zh":[{"name":"雷电冲击至 Up = 4500 kV"},{"name":"操作冲击至 Up = 2800 kV"}],"search_zh":"Un = (1 - 400) kV 线路用绝缘子与绝缘子串 冲击电压下的介电强度： 雷电冲击至 Up = 4500 kV 操作冲击至 Up = 2800 kV PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN IEC 60383-1:2024-04 | IEC 60383-1:2023 | PN-IEC 383-2:1997 | PN-IEC 383-2:1997/Ap1:2002 | IEC 60383-2:1993 | PN-EN 61109:2010 | IEC 61109:2025 | PN-EN 60137:2018-02 | PN-EN 60137:2018-02/AC:2018-10 | IEC 60137:2017 | IEC 60137:2017/COR1:2018 | PN-EN 60137:2018-02/AC:2018-10 | PN-EN 60168:1999 | PN-EN 60168:1999/A2:2002 | IEC 60168:1994+AMD1:1997 +AMD2:2000 CSV | PN-EN 60660:2002 | IEC 60660:1999 | PN-EN 50386:2010 | PN-EN 50386:2010/A1:2014 | PN-IEC 60720:2003 | IEC 60720:1981 | PN-EN IEC 60305:2021-10 | IEC 60305:2021 | PN-EN 61211:2005 | IEC 61211:2004 | PN-EN 61952:2010 | IEC 61952:2008 | PN-EN 62217:2013-06 | IEC 62217:2025 | PN-EN 62231:2008 | IEC 62231:2006","test_object_zh":"Un = (1 - 400) kV 线路用绝缘子与绝缘子串"},{"_id":"6a5dc9adf1c10c8ce825ac3b","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Izolatory i łańcuchy izolatorów dla linii o Un = (1 - 400) kV","test_object_en":"Insulators and insulator strings for lines with Un = (1 - 400) kV","methodology":"Wytrzymałość elektryczna przy napięciu przemiennym:","methodology_en":"Electric strength at alternating voltage:","parameters":[{"name":"50 Hz do Up = 1000 kV"},{"name":"Power frequency 50 Hz voltage"}],"parameters_en":[{"name":"50 Hz up to Up = 1000 kV"},{"name":"Power frequency 50 Hz voltage"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość elektryczna przy napięciu przemiennym:\nZakres:\n50 Hz do Up = 1000 kV\nPower frequency 50 Hz voltage","reference":"PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN IEC 60383-1:2024-04 | IEC 60383-1:2023 | PN-IEC 383-2:1997 | PN-IEC 383-2:1997/Ap1:2002 | IEC 60383-2:1993 | PN-EN 61109:2010 | IEC 61109:2025 | PN-EN 60137:2018-02 | PN-EN 60137:2018-02/AC:2018-10 | IEC 60137:2017 | IEC 60137:2017/COR1:2018 | PN-EN 60168:1999 | PN-EN 60168:1999/A2:2002 | IEC 60168:1994+AMD1:1997 +AMD2:2000 CSV | PN-EN 62155:2005 | IEC 62155:2003 | PN-EN 60660:2002 | IEC 60660:1999 | PN-EN 61952:2010 | IEC 61952:2008 | PN-IEC 60720:2003 | IEC 60720:1981 | PN-EN IEC 60305:2021-10 | IEC 60305:2021 | PN-EN 62217:2013-06 | IEC 62217:2025 | PN-EN 62231:2008 | IEC 62231:2006","norm_bases":["PN-EN 60060-1:2011","IEC 60060-1:2025","PN-EN 60060-2:2011","IEC 60060-2:2025","PN-EN IEC 60383-1:2024-04","IEC 60383-1:2023","PN-IEC 383-2:1997","PN-IEC 383-2:1997/Ap1:2002","IEC 60383-2:1993","PN-EN 61109:2010","IEC 61109:2025","PN-EN 60137:2018-02","PN-EN 60137:2018-02/AC:2018-10","IEC 60137:2017","IEC 60137:2017/COR1:2018","PN-EN 60168:1999","PN-EN 60168:1999/A2:2002","IEC 60168:1994+AMD1:1997 +AMD2:2000 CSV","PN-EN 62155:2005","IEC 62155:2003","PN-EN 60660:2002","IEC 60660:1999","PN-EN 61952:2010","IEC 61952:2008","PN-IEC 60720:2003","IEC 60720:1981","PN-EN IEC 60305:2021-10","IEC 60305:2021","PN-EN 62217:2013-06","IEC 62217:2025","PN-EN 62231:2008","IEC 62231:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Izolatory i łańcuchy izolatorów dla linii o Un = (1 - 400) kV Wytrzymałość elektryczna przy napięciu przemiennym:\nZakres:\n50 Hz do Up = 1000 kV\nPower frequency 50 Hz voltage PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN IEC 60383-1:2024-04 | IEC 60383-1:2023 | PN-IEC 383-2:1997 | PN-IEC 383-2:1997/Ap1:2002 | IEC 60383-2:1993 | PN-EN 61109:2010 | IEC 61109:2025 | PN-EN 60137:2018-02 | PN-EN 60137:2018-02/AC:2018-10 | IEC 60137:2017 | IEC 60137:2017/COR1:2018 | PN-EN 60168:1999 | PN-EN 60168:1999/A2:2002 | IEC 60168:1994+AMD1:1997 +AMD2:2000 CSV | PN-EN 62155:2005 | IEC 62155:2003 | PN-EN 60660:2002 | IEC 60660:1999 | PN-EN 61952:2010 | IEC 61952:2008 | PN-IEC 60720:2003 | IEC 60720:1981 | PN-EN IEC 60305:2021-10 | IEC 60305:2021 | PN-EN 62217:2013-06 | IEC 62217:2025 | PN-EN 62231:2008 | IEC 62231:2006 Izolatory i lancuchy izolatorow dla linii o Un = (1 - 400) kV Wytrzymalosc elektryczna przy napieciu przemiennym:\nZakres:\n50 Hz do Up = 1000 kV\nPower frequency 50 Hz voltage PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN IEC 60383-1:2024-04 | IEC 60383-1:2023 | PN-IEC 383-2:1997 | PN-IEC 383-2:1997/Ap1:2002 | IEC 60383-2:1993 | PN-EN 61109:2010 | IEC 61109:2025 | PN-EN 60137:2018-02 | PN-EN 60137:2018-02/AC:2018-10 | IEC 60137:2017 | IEC 60137:2017/COR1:2018 | PN-EN 60168:1999 | PN-EN 60168:1999/A2:2002 | IEC 60168:1994+AMD1:1997 +AMD2:2000 CSV | PN-EN 62155:2005 | IEC 62155:2003 | PN-EN 60660:2002 | IEC 60660:1999 | PN-EN 61952:2010 | IEC 61952:2008 | PN-IEC 60720:2003 | IEC 60720:1981 | PN-EN IEC 60305:2021-10 | IEC 60305:2021 | PN-EN 62217:2013-06 | IEC 62217:2025 | PN-EN 62231:2008 | IEC 62231:2006","categories":["other"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Insulators and insulator strings for lines with Un = (1 - 400) kV Electric strength at alternating voltage: 50 Hz up to Up = 1000 kV Power frequency 50 Hz voltage PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN IEC 60383-1:2024-04 | IEC 60383-1:2023 | PN-IEC 383-2:1997 | PN-IEC 383-2:1997/Ap1:2002 | IEC 60383-2:1993 | PN-EN 61109:2010 | IEC 61109:2025 | PN-EN 60137:2018-02 | PN-EN 60137:2018-02/AC:2018-10 | IEC 60137:2017 | IEC 60137:2017/COR1:2018 | PN-EN 60168:1999 | PN-EN 60168:1999/A2:2002 | IEC 60168:1994+AMD1:1997 +AMD2:2000 CSV | PN-EN 62155:2005 | IEC 62155:2003 | PN-EN 60660:2002 | IEC 60660:1999 | PN-EN 61952:2010 | IEC 61952:2008 | PN-IEC 60720:2003 | IEC 60720:1981 | PN-EN IEC 60305:2021-10 | IEC 60305:2021 | PN-EN 62217:2013-06 | IEC 62217:2025 | PN-EN 62231:2008 | IEC 62231:2006","search_zh":"Un = (1 - 400) kV 线路用绝缘子与绝缘子串 交流电压下的介电强度： PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN IEC 60383-1:2024-04 | IEC 60383-1:2023 | PN-IEC 383-2:1997 | PN-IEC 383-2:1997/Ap1:2002 | IEC 60383-2:1993 | PN-EN 61109:2010 | IEC 61109:2025 | PN-EN 60137:2018-02 | PN-EN 60137:2018-02/AC:2018-10 | IEC 60137:2017 | IEC 60137:2017/COR1:2018 | PN-EN 60168:1999 | PN-EN 60168:1999/A2:2002 | IEC 60168:1994+AMD1:1997 +AMD2:2000 CSV | PN-EN 62155:2005 | IEC 62155:2003 | PN-EN 60660:2002 | IEC 60660:1999 | PN-EN 61952:2010 | IEC 61952:2008 | PN-IEC 60720:2003 | IEC 60720:1981 | PN-EN IEC 60305:2021-10 | IEC 60305:2021 | PN-EN 62217:2013-06 | IEC 62217:2025 | PN-EN 62231:2008 | IEC 62231:2006","test_object_zh":"Un = (1 - 400) kV 线路用绝缘子与绝缘子串","methodology_zh":"交流电压下的介电强度："},{"_id":"6a5dc9adf1c10c8ce825ac3c","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Izolatory i łańcuchy izolatorów dla linii o Un = (1 - 400) kV","test_object_en":"Insulators and insulator strings for lines with Un = (1 - 400) kV","methodology":"Poziom zakłóceń radioelektrycznych (RIV) i poziom wyładowań niezupełnych (PD): do Up = 400 kV","methodology_en":"Radio interference voltage level (RIV) and partial discharge level (PD): up to Up = 400 kV","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Poziom zakłóceń radioelektrycznych (RIV) i poziom wyładowań niezupełnych (PD): do Up = 400 kV","reference":"PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 60137:2018-02 | PN-EN 60137:2018-02/AC:2018-10 | IEC 60137:2017 | IEC 60137:2017/COR1:2018 CISPR TR 18-2:2017 | PN-EN 60270:2003 | PN-EN 60270:2003/A1:2016-04 | IEC 60270:2000+AMD1:2015 CSV | PN-EN IEC 60437:2024-09 | IEC 60437:2023 | PN-EN 61952:2010 | IEC 61952:2008 | PN-EN IEC 60383-1:2024-04 | IEC 60383-1:2023","norm_bases":["PN-EN 60060-1:2011","IEC 60060-1:2025","PN-EN 60060-2:2011","IEC 60060-2:2025","PN-EN 60137:2018-02","PN-EN 60137:2018-02/AC:2018-10","IEC 60137:2017","IEC 60137:2017/COR1:2018 CISPR TR 18-2:2017","PN-EN 60270:2003","PN-EN 60270:2003/A1:2016-04","IEC 60270:2000+AMD1:2015 CSV","PN-EN IEC 60437:2024-09","IEC 60437:2023","PN-EN 61952:2010","IEC 61952:2008","PN-EN IEC 60383-1:2024-04","IEC 60383-1:2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Izolatory i łańcuchy izolatorów dla linii o Un = (1 - 400) kV Poziom zakłóceń radioelektrycznych (RIV) i poziom wyładowań niezupełnych (PD): do Up = 400 kV PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 60137:2018-02 | PN-EN 60137:2018-02/AC:2018-10 | IEC 60137:2017 | IEC 60137:2017/COR1:2018 CISPR TR 18-2:2017 | PN-EN 60270:2003 | PN-EN 60270:2003/A1:2016-04 | IEC 60270:2000+AMD1:2015 CSV | PN-EN IEC 60437:2024-09 | IEC 60437:2023 | PN-EN 61952:2010 | IEC 61952:2008 | PN-EN IEC 60383-1:2024-04 | IEC 60383-1:2023 Izolatory i lancuchy izolatorow dla linii o Un = (1 - 400) kV Poziom zaklocen radioelektrycznych (RIV) i poziom wyladowan niezupelnych (PD): do Up = 400 kV PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 60137:2018-02 | PN-EN 60137:2018-02/AC:2018-10 | IEC 60137:2017 | IEC 60137:2017/COR1:2018 CISPR TR 18-2:2017 | PN-EN 60270:2003 | PN-EN 60270:2003/A1:2016-04 | IEC 60270:2000+AMD1:2015 CSV | PN-EN IEC 60437:2024-09 | IEC 60437:2023 | PN-EN 61952:2010 | IEC 61952:2008 | PN-EN IEC 60383-1:2024-04 | IEC 60383-1:2023","categories":["other"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Insulators and insulator strings for lines with Un = (1 - 400) kV Radio interference voltage level (RIV) and partial discharge level (PD): up to Up = 400 kV PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 60137:2018-02 | PN-EN 60137:2018-02/AC:2018-10 | IEC 60137:2017 | IEC 60137:2017/COR1:2018 CISPR TR 18-2:2017 | PN-EN 60270:2003 | PN-EN 60270:2003/A1:2016-04 | IEC 60270:2000+AMD1:2015 CSV | PN-EN IEC 60437:2024-09 | IEC 60437:2023 | PN-EN 61952:2010 | IEC 61952:2008 | PN-EN IEC 60383-1:2024-04 | IEC 60383-1:2023","search_zh":"Un = (1 - 400) kV 线路用绝缘子与绝缘子串 PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 60137:2018-02 | PN-EN 60137:2018-02/AC:2018-10 | IEC 60137:2017 | IEC 60137:2017/COR1:2018 CISPR TR 18-2:2017 | PN-EN 60270:2003 | PN-EN 60270:2003/A1:2016-04 | IEC 60270:2000+AMD1:2015 CSV | PN-EN IEC 60437:2024-09 | IEC 60437:2023 | PN-EN 61952:2010 | IEC 61952:2008 | PN-EN IEC 60383-1:2024-04 | IEC 60383-1:2023","test_object_zh":"Un = (1 - 400) kV 线路用绝缘子与绝缘子串"},{"_id":"6a5dc9adf1c10c8ce825ac3d","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Izolatory i łańcuchy izolatorów dla linii o Un = (1 - 400) kV","test_object_en":"Insulators and insulator strings for lines with Un = (1 - 400) kV","methodology":"Odporność na wyładowania pełzne i erozję, próba w mgle solnej: do Up = 100 kV","methodology_en":"Resistance to tracking and erosion, salt fog test: up to Up = 100 kV","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na wyładowania pełzne i erozję, próba w mgle solnej: do Up = 100 kV","reference":"PN-EN 61109:2010 | IEC 61109:2025 | PN-EN 62217:2013-06 | IEC 62217:2025 | PN-EN IEC 61462:2024-06 | IEC 61462:2023 | PN-EN 61952:2010 | IEC 61952:2008","norm_bases":["PN-EN 61109:2010","IEC 61109:2025","PN-EN 62217:2013-06","IEC 62217:2025","PN-EN IEC 61462:2024-06","IEC 61462:2023","PN-EN 61952:2010","IEC 61952:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Izolatory i łańcuchy izolatorów dla linii o Un = (1 - 400) kV Odporność na wyładowania pełzne i erozję, próba w mgle solnej: do Up = 100 kV PN-EN 61109:2010 | IEC 61109:2025 | PN-EN 62217:2013-06 | IEC 62217:2025 | PN-EN IEC 61462:2024-06 | IEC 61462:2023 | PN-EN 61952:2010 | IEC 61952:2008 Izolatory i lancuchy izolatorow dla linii o Un = (1 - 400) kV Odpornosc na wyladowania pelzne i erozje, proba w mgle solnej: do Up = 100 kV PN-EN 61109:2010 | IEC 61109:2025 | PN-EN 62217:2013-06 | IEC 62217:2025 | PN-EN IEC 61462:2024-06 | IEC 61462:2023 | PN-EN 61952:2010 | IEC 61952:2008","categories":["other"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Insulators and insulator strings for lines with Un = (1 - 400) kV Resistance to tracking and erosion, salt fog test: up to Up = 100 kV PN-EN 61109:2010 | IEC 61109:2025 | PN-EN 62217:2013-06 | IEC 62217:2025 | PN-EN IEC 61462:2024-06 | IEC 61462:2023 | PN-EN 61952:2010 | IEC 61952:2008","search_zh":"Un = (1 - 400) kV 线路用绝缘子与绝缘子串 PN-EN 61109:2010 | IEC 61109:2025 | PN-EN 62217:2013-06 | IEC 62217:2025 | PN-EN IEC 61462:2024-06 | IEC 61462:2023 | PN-EN 61952:2010 | IEC 61952:2008","test_object_zh":"Un = (1 - 400) kV 线路用绝缘子与绝缘子串"},{"_id":"6a5dc9adf1c10c8ce825ac3e","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Izolatory i łańcuchy izolatorów dla linii o Un = (1 - 400) kV","test_object_en":"Insulators and insulator strings for lines with Un = (1 - 400) kV","methodology":"Wytrzymałość mechaniczna:","methodology_en":"Mechanical strength:","parameters":[{"name":"rozciąganie do długości","range":"(2500 mm / do siły 200 kN)"},{"name":"rozciąganie","range":"(do długości 1400 mm / do siły 1000 kN)"},{"name":"próba wytrzymałości mechanicznej"}],"parameters_en":[{"name":"tension up to a length","range":"(2500 mm / do siły 200 kN)"},{"name":"tension","range":"(do długości 1400 mm / do siły 1000 kN)"},{"name":"mechanical strength test"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość mechaniczna:\nZakres:\nrozciąganie do długości (2500 mm / do siły 200 kN)\nrozciąganie (do długości 1400 mm / do siły 1000 kN)\npróba wytrzymałości mechanicznej","reference":"PN-EN IEC 60383-1:2024-04, pkt. 19 | IEC 60383-1:2023, clause 19 | PN-EN 61109:2010, pkt.10.3.2. | IEC 61109:2008, clause 10.3.2. | IEC 61109:2025, clause 9.3.3 | PN-EN 61467:2012 | IEC 61467:2008","norm_bases":["PN-EN IEC 60383-1:2024-04, pkt. 19","IEC 60383-1:2023, clause 19","PN-EN 61109:2010, pkt.10.3.2.","IEC 61109:2008, clause 10.3.2.","IEC 61109:2025, clause 9.3.3","PN-EN 61467:2012","IEC 61467:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Izolatory i łańcuchy izolatorów dla linii o Un = (1 - 400) kV Wytrzymałość mechaniczna:\nZakres:\nrozciąganie do długości (2500 mm / do siły 200 kN)\nrozciąganie (do długości 1400 mm / do siły 1000 kN)\npróba wytrzymałości mechanicznej PN-EN IEC 60383-1:2024-04, pkt. 19 | IEC 60383-1:2023, clause 19 | PN-EN 61109:2010, pkt.10.3.2. | IEC 61109:2008, clause 10.3.2. | IEC 61109:2025, clause 9.3.3 | PN-EN 61467:2012 | IEC 61467:2008 Izolatory i lancuchy izolatorow dla linii o Un = (1 - 400) kV Wytrzymalosc mechaniczna:\nZakres:\nrozciaganie do dlugosci (2500 mm / do sily 200 kN)\nrozciaganie (do dlugosci 1400 mm / do sily 1000 kN)\nproba wytrzymalosci mechanicznej PN-EN IEC 60383-1:2024-04, pkt. 19 | IEC 60383-1:2023, clause 19 | PN-EN 61109:2010, pkt.10.3.2. | IEC 61109:2008, clause 10.3.2. | IEC 61109:2025, clause 9.3.3 | PN-EN 61467:2012 | IEC 61467:2008","categories":["other"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Insulators and insulator strings for lines with Un = (1 - 400) kV Mechanical strength: tension up to a length tension mechanical strength test PN-EN IEC 60383-1:2024-04, pkt. 19 | IEC 60383-1:2023, clause 19 | PN-EN 61109:2010, pkt.10.3.2. | IEC 61109:2008, clause 10.3.2. | IEC 61109:2025, clause 9.3.3 | PN-EN 61467:2012 | IEC 61467:2008","search_zh":"Un = (1 - 400) kV 线路用绝缘子与绝缘子串 PN-EN IEC 60383-1:2024-04, pkt. 19 | IEC 60383-1:2023, clause 19 | PN-EN 61109:2010, pkt.10.3.2. | IEC 61109:2008, clause 10.3.2. | IEC 61109:2025, clause 9.3.3 | PN-EN 61467:2012 | IEC 61467:2008","test_object_zh":"Un = (1 - 400) kV 线路用绝缘子与绝缘子串"},{"_id":"6a5dc9adf1c10c8ce825ac3f","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Izolatory i łańcuchy izolatorów dla linii o Un = (1 - 400) kV","test_object_en":"Insulators and insulator strings for lines with Un = (1 - 400) kV","methodology":"Wytrzymałość mechaniczna:","methodology_en":"Mechanical strength:","parameters":[{"name":"zginanie","range":"(do wysokości 500 mm / do siły 200 kN)"},{"name":"próba wytrzymałości mechanicznej"}],"parameters_en":[{"name":"bending","range":"(do wysokości 500 mm / do siły 200 kN)"},{"name":"mechanical strength test"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość mechaniczna:\nZakres:\nzginanie (do wysokości 500 mm / do siły 200 kN)\npróba wytrzymałości mechanicznej","reference":"PN-EN IEC 60383-1:2024-04, pkt. 19 | IEC 60383-1:2023, clause 19 | PN-EN 61952:2010, pkt. 10.3.1 | IEC 61952:2008, clause 10.3.1 | PN-EN 62231:2008, pkt. 8.2.4 | IEC 62231:2006, clause 8.2.4","norm_bases":["PN-EN IEC 60383-1:2024-04, pkt. 19","IEC 60383-1:2023, clause 19","PN-EN 61952:2010, pkt. 10.3.1","IEC 61952:2008, clause 10.3.1","PN-EN 62231:2008, pkt. 8.2.4","IEC 62231:2006, clause 8.2.4"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Izolatory i łańcuchy izolatorów dla linii o Un = (1 - 400) kV Wytrzymałość mechaniczna:\nZakres:\nzginanie (do wysokości 500 mm / do siły 200 kN)\npróba wytrzymałości mechanicznej PN-EN IEC 60383-1:2024-04, pkt. 19 | IEC 60383-1:2023, clause 19 | PN-EN 61952:2010, pkt. 10.3.1 | IEC 61952:2008, clause 10.3.1 | PN-EN 62231:2008, pkt. 8.2.4 | IEC 62231:2006, clause 8.2.4 Izolatory i lancuchy izolatorow dla linii o Un = (1 - 400) kV Wytrzymalosc mechaniczna:\nZakres:\nzginanie (do wysokosci 500 mm / do sily 200 kN)\nproba wytrzymalosci mechanicznej PN-EN IEC 60383-1:2024-04, pkt. 19 | IEC 60383-1:2023, clause 19 | PN-EN 61952:2010, pkt. 10.3.1 | IEC 61952:2008, clause 10.3.1 | PN-EN 62231:2008, pkt. 8.2.4 | IEC 62231:2006, clause 8.2.4","categories":["other"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Insulators and insulator strings for lines with Un = (1 - 400) kV Mechanical strength: bending mechanical strength test PN-EN IEC 60383-1:2024-04, pkt. 19 | IEC 60383-1:2023, clause 19 | PN-EN 61952:2010, pkt. 10.3.1 | IEC 61952:2008, clause 10.3.1 | PN-EN 62231:2008, pkt. 8.2.4 | IEC 62231:2006, clause 8.2.4","search_zh":"Un = (1 - 400) kV 线路用绝缘子与绝缘子串 PN-EN IEC 60383-1:2024-04, pkt. 19 | IEC 60383-1:2023, clause 19 | PN-EN 61952:2010, pkt. 10.3.1 | IEC 61952:2008, clause 10.3.1 | PN-EN 62231:2008, pkt. 8.2.4 | IEC 62231:2006, clause 8.2.4","test_object_zh":"Un = (1 - 400) kV 线路用绝缘子与绝缘子串"},{"_id":"6a5dc9adf1c10c8ce825ac40","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Izolatory i łańcuchy izolatorów dla linii o Un = (1 - 400) kV","test_object_en":"Insulators and insulator strings for lines with Un = (1 - 400) kV","methodology":"Wytrzymałość termomechaniczna:","methodology_en":"Thermomechanical strength:","parameters":[{"name":"rozciąganie","range":"(do długości 2500 mm / do siły 200 kN)"},{"name":"Zakres temperatury","range":"-60 °C ÷ 60 °C"},{"name":"próba termomechaniczna"}],"parameters_en":[{"name":"tension","range":"(do długości 2500 mm / do siły 200 kN)"},{"name":"Temperature range","range":"-60 °C ÷ 60 °C"},{"name":"thermomechanical test"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość termomechaniczna:\nZakres:\nrozciąganie (do długości 2500 mm / do siły 200 kN)\nZakres temperatury -60 °C ÷ 60 °C\npróba termomechaniczna","reference":"PN-EN IEC 60383-1:2024-04, pkt. 20 | IEC 60383-1:2023, clause 20 | PN-EN 61109:2010, pkt. 10.3.2. | IEC 61109:2008, clause 10.3.2. | IEC 61109:2025, clause 9.3.3","norm_bases":["PN-EN IEC 60383-1:2024-04, pkt. 20","IEC 60383-1:2023, clause 20","PN-EN 61109:2010, pkt. 10.3.2.","IEC 61109:2008, clause 10.3.2.","IEC 61109:2025, clause 9.3.3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Izolatory i łańcuchy izolatorów dla linii o Un = (1 - 400) kV Wytrzymałość termomechaniczna:\nZakres:\nrozciąganie (do długości 2500 mm / do siły 200 kN)\nZakres temperatury -60 °C ÷ 60 °C\npróba termomechaniczna PN-EN IEC 60383-1:2024-04, pkt. 20 | IEC 60383-1:2023, clause 20 | PN-EN 61109:2010, pkt. 10.3.2. | IEC 61109:2008, clause 10.3.2. | IEC 61109:2025, clause 9.3.3 Izolatory i lancuchy izolatorow dla linii o Un = (1 - 400) kV Wytrzymalosc termomechaniczna:\nZakres:\nrozciaganie (do dlugosci 2500 mm / do sily 200 kN)\nZakres temperatury -60 °C ÷ 60 °C\nproba termomechaniczna PN-EN IEC 60383-1:2024-04, pkt. 20 | IEC 60383-1:2023, clause 20 | PN-EN 61109:2010, pkt. 10.3.2. | IEC 61109:2008, clause 10.3.2. | IEC 61109:2025, clause 9.3.3","categories":["other"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Insulators and insulator strings for lines with Un = (1 - 400) kV Thermomechanical strength: tension Temperature range thermomechanical test PN-EN IEC 60383-1:2024-04, pkt. 20 | IEC 60383-1:2023, clause 20 | PN-EN 61109:2010, pkt. 10.3.2. | IEC 61109:2008, clause 10.3.2. | IEC 61109:2025, clause 9.3.3","parameters_zh":[{"name":"rozciąganie","range":"(do długości 2500 mm / do siły 200 kN)"},{"name":"温度范围","range":"-60 °C ÷ 60 °C"},{"name":"próba termomechaniczna"}],"search_zh":"Un = (1 - 400) kV 线路用绝缘子与绝缘子串 温度范围 PN-EN IEC 60383-1:2024-04, pkt. 20 | IEC 60383-1:2023, clause 20 | PN-EN 61109:2010, pkt. 10.3.2. | IEC 61109:2008, clause 10.3.2. | IEC 61109:2025, clause 9.3.3","test_object_zh":"Un = (1 - 400) kV 线路用绝缘子与绝缘子串"},{"_id":"6a5dc9adf1c10c8ce825ac41","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Izolatory i łańcuchy izolatorów dla linii o Un = (1 - 400) kV","test_object_en":"Insulators and insulator strings for lines with Un = (1 - 400) kV","methodology":"Wytrzymałość termomechaniczna:","methodology_en":"Thermomechanical strength:","parameters":[{"name":"zginanie","range":"(do wysokości 500 mm / do siły 200 kN)"},{"name":"Zakres temperatury","range":"-60 °C ÷ 60 °C"},{"name":"próba termomechaniczna"}],"parameters_en":[{"name":"bending","range":"(do wysokości 500 mm / do siły 200 kN)"},{"name":"Temperature range","range":"-60 °C ÷ 60 °C"},{"name":"thermomechanical test"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość termomechaniczna:\nZakres:\nzginanie (do wysokości 500 mm / do siły 200 kN)\nZakres temperatury -60 °C ÷ 60 °C\npróba termomechaniczna","reference":"PN-EN 61952:2010, pkt. 10.3.1 | IEC 61952:2008, clause 10.3.1 | PN-EN 62231:2008, pkt. 8.2.4 | IEC 62231:2006, clause 8.2.4","norm_bases":["PN-EN 61952:2010, pkt. 10.3.1","IEC 61952:2008, clause 10.3.1","PN-EN 62231:2008, pkt. 8.2.4","IEC 62231:2006, clause 8.2.4"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Izolatory i łańcuchy izolatorów dla linii o Un = (1 - 400) kV Wytrzymałość termomechaniczna:\nZakres:\nzginanie (do wysokości 500 mm / do siły 200 kN)\nZakres temperatury -60 °C ÷ 60 °C\npróba termomechaniczna PN-EN 61952:2010, pkt. 10.3.1 | IEC 61952:2008, clause 10.3.1 | PN-EN 62231:2008, pkt. 8.2.4 | IEC 62231:2006, clause 8.2.4 Izolatory i lancuchy izolatorow dla linii o Un = (1 - 400) kV Wytrzymalosc termomechaniczna:\nZakres:\nzginanie (do wysokosci 500 mm / do sily 200 kN)\nZakres temperatury -60 °C ÷ 60 °C\nproba termomechaniczna PN-EN 61952:2010, pkt. 10.3.1 | IEC 61952:2008, clause 10.3.1 | PN-EN 62231:2008, pkt. 8.2.4 | IEC 62231:2006, clause 8.2.4","categories":["other"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Insulators and insulator strings for lines with Un = (1 - 400) kV Thermomechanical strength: bending Temperature range thermomechanical test PN-EN 61952:2010, pkt. 10.3.1 | IEC 61952:2008, clause 10.3.1 | PN-EN 62231:2008, pkt. 8.2.4 | IEC 62231:2006, clause 8.2.4","parameters_zh":[{"name":"zginanie","range":"(do wysokości 500 mm / do siły 200 kN)"},{"name":"温度范围","range":"-60 °C ÷ 60 °C"},{"name":"próba termomechaniczna"}],"search_zh":"Un = (1 - 400) kV 线路用绝缘子与绝缘子串 温度范围 PN-EN 61952:2010, pkt. 10.3.1 | IEC 61952:2008, clause 10.3.1 | PN-EN 62231:2008, pkt. 8.2.4 | IEC 62231:2006, clause 8.2.4","test_object_zh":"Un = (1 - 400) kV 线路用绝缘子与绝缘子串"},{"_id":"6a5dc9adf1c10c8ce825ac42","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Izolatory i łańcuchy izolatorów dla linii o Un = (1 - 400) kV","test_object_en":"Insulators and insulator strings for lines with Un = (1 - 400) kV","methodology":"Próba mechanicznej wytrzymałości resztkowej, Residual strength test, Próba uderzeniowa","methodology_en":"Residual strength test, Impact test","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Próba mechanicznej wytrzymałości resztkowej, Residual strength test, Próba uderzeniowa","reference":"IEC TR 60797:1984 | PN-EN IEC 60383-1:2024-04 | IEC 60383-1:2023","norm_bases":["IEC TR 60797:1984","PN-EN IEC 60383-1:2024-04","IEC 60383-1:2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Izolatory i łańcuchy izolatorów dla linii o Un = (1 - 400) kV Próba mechanicznej wytrzymałości resztkowej, Residual strength test, Próba uderzeniowa IEC TR 60797:1984 | PN-EN IEC 60383-1:2024-04 | IEC 60383-1:2023 Izolatory i lancuchy izolatorow dla linii o Un = (1 - 400) kV Proba mechanicznej wytrzymalosci resztkowej, Residual strength test, Proba uderzeniowa IEC TR 60797:1984 | PN-EN IEC 60383-1:2024-04 | IEC 60383-1:2023","categories":["other"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Insulators and insulator strings for lines with Un = (1 - 400) kV Residual strength test, Impact test IEC TR 60797:1984 | PN-EN IEC 60383-1:2024-04 | IEC 60383-1:2023","search_zh":"Un = (1 - 400) kV 线路用绝缘子与绝缘子串 IEC TR 60797:1984 | PN-EN IEC 60383-1:2024-04 | IEC 60383-1:2023","test_object_zh":"Un = (1 - 400) kV 线路用绝缘子与绝缘子串"},{"_id":"6a5dc9adf1c10c8ce825ac43","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Stacje rozdzielcze o Un = (3,6 - 400) kV, Substations, switchgear","test_object_en":"Substations, switchgear with Un = (3,6 - 400) kV","methodology":"Wytrzymałość elektryczna przy napięciu udarowym:","methodology_en":"Dielectric strength at impulse voltage:","parameters":[{"name":"piorunowym do Up = 4500 kV"},{"name":"łączeniowym do Up = 2800 kV"}],"parameters_en":[{"name":"lightning up to Up = 4500 kV"},{"name":"switching up to Up = 2800 kV"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość elektryczna przy napięciu udarowym:\nZakres:\npiorunowym do Up = 4500 kV\nłączeniowym do Up = 2800 kV","reference":"PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 CSV | PN-EN IEC 62271-200:2022-02 | IEC 62271-200:2021 | PN-EN IEC 62271-202:2023-03 | IEC 62271-202:2022 | PN-EN 62271-203:2012 | IEC 62271-203:2022","norm_bases":["PN-EN 60060-1:2011","IEC 60060-1:2025","PN-EN 60060-2:2011","IEC 60060-2:2025","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-1:2017+AMD1:2021 CSV","PN-EN IEC 62271-200:2022-02","IEC 62271-200:2021","PN-EN IEC 62271-202:2023-03","IEC 62271-202:2022","PN-EN 62271-203:2012","IEC 62271-203:2022"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stacje rozdzielcze o Un = (3,6 - 400) kV, Substations, switchgear Wytrzymałość elektryczna przy napięciu udarowym:\nZakres:\npiorunowym do Up = 4500 kV\nłączeniowym do Up = 2800 kV PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 CSV | PN-EN IEC 62271-200:2022-02 | IEC 62271-200:2021 | PN-EN IEC 62271-202:2023-03 | IEC 62271-202:2022 | PN-EN 62271-203:2012 | IEC 62271-203:2022 Stacje rozdzielcze o Un = (3,6 - 400) kV, Substations, switchgear Wytrzymalosc elektryczna przy napieciu udarowym:\nZakres:\npiorunowym do Up = 4500 kV\nlaczeniowym do Up = 2800 kV PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 CSV | PN-EN IEC 62271-200:2022-02 | IEC 62271-200:2021 | PN-EN IEC 62271-202:2023-03 | IEC 62271-202:2022 | PN-EN 62271-203:2012 | IEC 62271-203:2022","categories":["other"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Substations, switchgear with Un = (3,6 - 400) kV Dielectric strength at impulse voltage: lightning up to Up = 4500 kV switching up to Up = 2800 kV PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 CSV | PN-EN IEC 62271-200:2022-02 | IEC 62271-200:2021 | PN-EN IEC 62271-202:2023-03 | IEC 62271-202:2022 | PN-EN 62271-203:2012 | IEC 62271-203:2022","methodology_zh":"冲击电压下的介电强度：","parameters_zh":[{"name":"雷电冲击至 Up = 4500 kV"},{"name":"操作冲击至 Up = 2800 kV"}],"search_zh":"冲击电压下的介电强度： 雷电冲击至 Up = 4500 kV 操作冲击至 Up = 2800 kV PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 CSV | PN-EN IEC 62271-200:2022-02 | IEC 62271-200:2021 | PN-EN IEC 62271-202:2023-03 | IEC 62271-202:2022 | PN-EN 62271-203:2012 | IEC 62271-203:2022"},{"_id":"6a5dc9adf1c10c8ce825ac44","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Stacje rozdzielcze o Un = (3,6 - 400) kV, Substations, switchgear","test_object_en":"Substations, switchgear with Un = (3,6 - 400) kV","methodology":"Wytrzymałość elektryczna przy napięciu przemiennym: 50 Hz do Up = 1000 kV","methodology_en":"Electric strength at alternating voltage: 50 Hz up to Up = 1000 kV","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość elektryczna przy napięciu przemiennym: 50 Hz do Up = 1000 kV","reference":"PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 CSV | PN-EN IEC 62271-200:2022-02 | IEC 62271-200:2021 | PN-EN IEC 62271-202:2023-03 | IEC 62271-202:2022 | PN-EN 62271-203:2012 | IEC 62271-203:2022","norm_bases":["PN-EN 60060-1:2011","IEC 60060-1:2025","PN-EN 60060-2:2011","IEC 60060-2:2025","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-1:2017+AMD1:2021 CSV","PN-EN IEC 62271-200:2022-02","IEC 62271-200:2021","PN-EN IEC 62271-202:2023-03","IEC 62271-202:2022","PN-EN 62271-203:2012","IEC 62271-203:2022"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stacje rozdzielcze o Un = (3,6 - 400) kV, Substations, switchgear Wytrzymałość elektryczna przy napięciu przemiennym: 50 Hz do Up = 1000 kV PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 CSV | PN-EN IEC 62271-200:2022-02 | IEC 62271-200:2021 | PN-EN IEC 62271-202:2023-03 | IEC 62271-202:2022 | PN-EN 62271-203:2012 | IEC 62271-203:2022 Stacje rozdzielcze o Un = (3,6 - 400) kV, Substations, switchgear Wytrzymalosc elektryczna przy napieciu przemiennym: 50 Hz do Up = 1000 kV PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 CSV | PN-EN IEC 62271-200:2022-02 | IEC 62271-200:2021 | PN-EN IEC 62271-202:2023-03 | IEC 62271-202:2022 | PN-EN 62271-203:2012 | IEC 62271-203:2022","categories":["other"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Substations, switchgear with Un = (3,6 - 400) kV Electric strength at alternating voltage: 50 Hz up to Up = 1000 kV PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 CSV | PN-EN IEC 62271-200:2022-02 | IEC 62271-200:2021 | PN-EN IEC 62271-202:2023-03 | IEC 62271-202:2022 | PN-EN 62271-203:2012 | IEC 62271-203:2022","methodology_zh":"交流电压下的介电强度：50 Hz 至 Up = 1000 kV","search_zh":"交流电压下的介电强度：50 Hz 至 Up = 1000 kV PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 CSV | PN-EN IEC 62271-200:2022-02 | IEC 62271-200:2021 | PN-EN IEC 62271-202:2023-03 | IEC 62271-202:2022 | PN-EN 62271-203:2012 | IEC 62271-203:2022"},{"_id":"6a5dc9adf1c10c8ce825ac45","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Stacje rozdzielcze o Un = (3,6 - 400) kV, Substations, switchgear","test_object_en":"Substations, switchgear with Un = (3,6 - 400) kV","methodology":"Poziom zakłóceń radioelektrycznych (RIV) i poziom wyładowań niezupełnych (PD): maksymalne Up = 400 kV","methodology_en":"Radio interference voltage level (RIV) and partial discharge level (PD): maximum Up = 400 kV","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Poziom zakłóceń radioelektrycznych (RIV) i poziom wyładowań niezupełnych (PD): maksymalne Up = 400 kV","reference":"PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 CISPR TR 18-2:2017 | PN-EN 60270:2003 | PN-EN 60270:2003/A1:2016-04 | IEC 60270:2000+AMD1:2015 CSV | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 CSV | PN-EN IEC 62271-200:2022-02 | IEC 62271-200:2021 | PN-EN 62271-201-2014-12 | IEC 62271-201:2014 | PN-EN 62271-203:2012 | IEC 62271-203:2022 | PN-EN 62271-205:2008 | IEC 62271-205:2008","norm_bases":["PN-EN 60060-1:2011","IEC 60060-1:2025","PN-EN 60060-2:2011","IEC 60060-2:2025 CISPR TR 18-2:2017","PN-EN 60270:2003","PN-EN 60270:2003/A1:2016-04","IEC 60270:2000+AMD1:2015 CSV","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-1:2017+AMD1:2021 CSV","PN-EN IEC 62271-200:2022-02","IEC 62271-200:2021","PN-EN 62271-201-2014-12","IEC 62271-201:2014","PN-EN 62271-203:2012","IEC 62271-203:2022","PN-EN 62271-205:2008","IEC 62271-205:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stacje rozdzielcze o Un = (3,6 - 400) kV, Substations, switchgear Poziom zakłóceń radioelektrycznych (RIV) i poziom wyładowań niezupełnych (PD): maksymalne Up = 400 kV PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 CISPR TR 18-2:2017 | PN-EN 60270:2003 | PN-EN 60270:2003/A1:2016-04 | IEC 60270:2000+AMD1:2015 CSV | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 CSV | PN-EN IEC 62271-200:2022-02 | IEC 62271-200:2021 | PN-EN 62271-201-2014-12 | IEC 62271-201:2014 | PN-EN 62271-203:2012 | IEC 62271-203:2022 | PN-EN 62271-205:2008 | IEC 62271-205:2008 Stacje rozdzielcze o Un = (3,6 - 400) kV, Substations, switchgear Poziom zaklocen radioelektrycznych (RIV) i poziom wyladowan niezupelnych (PD): maksymalne Up = 400 kV PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 CISPR TR 18-2:2017 | PN-EN 60270:2003 | PN-EN 60270:2003/A1:2016-04 | IEC 60270:2000+AMD1:2015 CSV | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 CSV | PN-EN IEC 62271-200:2022-02 | IEC 62271-200:2021 | PN-EN 62271-201-2014-12 | IEC 62271-201:2014 | PN-EN 62271-203:2012 | IEC 62271-203:2022 | PN-EN 62271-205:2008 | IEC 62271-205:2008","categories":["other"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Substations, switchgear with Un = (3,6 - 400) kV Radio interference voltage level (RIV) and partial discharge level (PD): maximum Up = 400 kV PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 CISPR TR 18-2:2017 | PN-EN 60270:2003 | PN-EN 60270:2003/A1:2016-04 | IEC 60270:2000+AMD1:2015 CSV | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 CSV | PN-EN IEC 62271-200:2022-02 | IEC 62271-200:2021 | PN-EN 62271-201-2014-12 | IEC 62271-201:2014 | PN-EN 62271-203:2012 | IEC 62271-203:2022 | PN-EN 62271-205:2008 | IEC 62271-205:2008","methodology_zh":"无线电干扰电压（RIV）与局部放电（PD）水平：最大 Up = 400 kV","search_zh":"无线电干扰电压（RIV）与局部放电（PD）水平：最大 Up = 400 kV PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 CISPR TR 18-2:2017 | PN-EN 60270:2003 | PN-EN 60270:2003/A1:2016-04 | IEC 60270:2000+AMD1:2015 CSV | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 CSV | PN-EN IEC 62271-200:2022-02 | IEC 62271-200:2021 | PN-EN 62271-201-2014-12 | IEC 62271-201:2014 | PN-EN 62271-203:2012 | IEC 62271-203:2022 | PN-EN 62271-205:2008 | IEC 62271-205:2008"},{"_id":"6a5dc9adf1c10c8ce825ac46","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Wyłączniki, rozłączniki i reklozery o Un = (3,6 - 400) kV, Circuit breakers, switches","test_object_en":"Circuit breakers, switch-disconnectors and reclosers with Un = (3,6 - 400) kV","methodology":"Wytrzymałość elektryczna przy napięciu udarowym:","methodology_en":"Dielectric strength at impulse voltage:","parameters":[{"name":"piorunowym do Up = 4500 kV"},{"name":"łączeniowym do Up = 2800 kV"}],"parameters_en":[{"name":"lightning up to Up = 4500 kV"},{"name":"switching up to Up = 2800 kV"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość elektryczna przy napięciu udarowym:\nZakres:\npiorunowym do Up = 4500 kV\nłączeniowym do Up = 2800 kV","reference":"PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 CSV | PN-EN IEC 62271-103:2024-04 | IEC 62271-103:2021 | PN-EN IEC 62271-100:2022-04 | PN-EN IEC 62271-100:2022-04/AC:2022-11 | PN-EN IEC 62271-100:2022-04/AC:2024-03 | IEC 62271-100:2021 | IEC 62271-100:2021/COR1:2021 | IEC 62271-100:2021/COR2:2022 | IEC 62271-100:2021/COR3:2024 | PN-EN IEC 62271-107:2020-01 | IEC 62271-107:2019 | IEC 62271-111:2019","norm_bases":["PN-EN 60060-1:2011","IEC 60060-1:2025","PN-EN 60060-2:2011","IEC 60060-2:2025","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-1:2017+AMD1:2021 CSV","PN-EN IEC 62271-103:2024-04","IEC 62271-103:2021","PN-EN IEC 62271-100:2022-04","PN-EN IEC 62271-100:2022-04/AC:2022-11","PN-EN IEC 62271-100:2022-04/AC:2024-03","IEC 62271-100:2021","IEC 62271-100:2021/COR1:2021","IEC 62271-100:2021/COR2:2022","IEC 62271-100:2021/COR3:2024","PN-EN IEC 62271-107:2020-01","IEC 62271-107:2019","IEC 62271-111:2019"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyłączniki, rozłączniki i reklozery o Un = (3,6 - 400) kV, Circuit breakers, switches Wytrzymałość elektryczna przy napięciu udarowym:\nZakres:\npiorunowym do Up = 4500 kV\nłączeniowym do Up = 2800 kV PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 CSV | PN-EN IEC 62271-103:2024-04 | IEC 62271-103:2021 | PN-EN IEC 62271-100:2022-04 | PN-EN IEC 62271-100:2022-04/AC:2022-11 | PN-EN IEC 62271-100:2022-04/AC:2024-03 | IEC 62271-100:2021 | IEC 62271-100:2021/COR1:2021 | IEC 62271-100:2021/COR2:2022 | IEC 62271-100:2021/COR3:2024 | PN-EN IEC 62271-107:2020-01 | IEC 62271-107:2019 | IEC 62271-111:2019 Wylaczniki, rozlaczniki i reklozery o Un = (3,6 - 400) kV, Circuit breakers, switches Wytrzymalosc elektryczna przy napieciu udarowym:\nZakres:\npiorunowym do Up = 4500 kV\nlaczeniowym do Up = 2800 kV PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 CSV | PN-EN IEC 62271-103:2024-04 | IEC 62271-103:2021 | PN-EN IEC 62271-100:2022-04 | PN-EN IEC 62271-100:2022-04/AC:2022-11 | PN-EN IEC 62271-100:2022-04/AC:2024-03 | IEC 62271-100:2021 | IEC 62271-100:2021/COR1:2021 | IEC 62271-100:2021/COR2:2022 | IEC 62271-100:2021/COR3:2024 | PN-EN IEC 62271-107:2020-01 | IEC 62271-107:2019 | IEC 62271-111:2019","categories":["other"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Circuit breakers, switch-disconnectors and reclosers with Un = (3,6 - 400) kV Dielectric strength at impulse voltage: lightning up to Up = 4500 kV switching up to Up = 2800 kV PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 CSV | PN-EN IEC 62271-103:2024-04 | IEC 62271-103:2021 | PN-EN IEC 62271-100:2022-04 | PN-EN IEC 62271-100:2022-04/AC:2022-11 | PN-EN IEC 62271-100:2022-04/AC:2024-03 | IEC 62271-100:2021 | IEC 62271-100:2021/COR1:2021 | IEC 62271-100:2021/COR2:2022 | IEC 62271-100:2021/COR3:2024 | PN-EN IEC 62271-107:2020-01 | IEC 62271-107:2019 | IEC 62271-111:2019","methodology_zh":"冲击电压下的介电强度：","parameters_zh":[{"name":"雷电冲击至 Up = 4500 kV"},{"name":"操作冲击至 Up = 2800 kV"}],"search_zh":"冲击电压下的介电强度： 雷电冲击至 Up = 4500 kV 操作冲击至 Up = 2800 kV PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 CSV | PN-EN IEC 62271-103:2024-04 | IEC 62271-103:2021 | PN-EN IEC 62271-100:2022-04 | PN-EN IEC 62271-100:2022-04/AC:2022-11 | PN-EN IEC 62271-100:2022-04/AC:2024-03 | IEC 62271-100:2021 | IEC 62271-100:2021/COR1:2021 | IEC 62271-100:2021/COR2:2022 | IEC 62271-100:2021/COR3:2024 | PN-EN IEC 62271-107:2020-01 | IEC 62271-107:2019 | IEC 62271-111:2019"},{"_id":"6a5dc9adf1c10c8ce825ac47","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Wyłączniki, rozłączniki i reklozery o Un = (3,6 - 400) kV, Circuit breakers, switches","test_object_en":"Circuit breakers, switch-disconnectors and reclosers with Un = (3,6 - 400) kV","methodology":"Wytrzymałość elektryczna przy napięciu przemiennym:","methodology_en":"Electric strength at alternating voltage:","parameters":[{"name":"50 Hz do Up = 1000 kV"},{"name":"Power frequency 50 Hz voltage"}],"parameters_en":[{"name":"50 Hz up to Up = 1000 kV"},{"name":"Power frequency 50 Hz voltage"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość elektryczna przy napięciu przemiennym:\nZakres:\n50 Hz do Up = 1000 kV\nPower frequency 50 Hz voltage","reference":"PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 CSV | PN-EN IEC 62271-103:2024-04 | IEC 62271-103:2021 | PN-EN IEC 62271-100:2022-04 | PN-EN IEC 62271-100:2022-04/AC:2022-11 | PN-EN IEC 62271-100:2022-04/AC:2024-03 | IEC 62271-100:2021 | IEC 62271-100:2021/COR1:2021 | IEC 62271-100:2021/COR2:2022 | IEC 62271-100:2021/COR3:2024 | PN-EN IEC 62271-107:2020-01 | IEC 62271-107:2019 | IEC 62271-111:2019","norm_bases":["PN-EN 60060-1:2011","IEC 60060-1:2025","PN-EN 60060-2:2011","IEC 60060-2:2025","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-1:2017+AMD1:2021 CSV","PN-EN IEC 62271-103:2024-04","IEC 62271-103:2021","PN-EN IEC 62271-100:2022-04","PN-EN IEC 62271-100:2022-04/AC:2022-11","PN-EN IEC 62271-100:2022-04/AC:2024-03","IEC 62271-100:2021","IEC 62271-100:2021/COR1:2021","IEC 62271-100:2021/COR2:2022","IEC 62271-100:2021/COR3:2024","PN-EN IEC 62271-107:2020-01","IEC 62271-107:2019","IEC 62271-111:2019"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyłączniki, rozłączniki i reklozery o Un = (3,6 - 400) kV, Circuit breakers, switches Wytrzymałość elektryczna przy napięciu przemiennym:\nZakres:\n50 Hz do Up = 1000 kV\nPower frequency 50 Hz voltage PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 CSV | PN-EN IEC 62271-103:2024-04 | IEC 62271-103:2021 | PN-EN IEC 62271-100:2022-04 | PN-EN IEC 62271-100:2022-04/AC:2022-11 | PN-EN IEC 62271-100:2022-04/AC:2024-03 | IEC 62271-100:2021 | IEC 62271-100:2021/COR1:2021 | IEC 62271-100:2021/COR2:2022 | IEC 62271-100:2021/COR3:2024 | PN-EN IEC 62271-107:2020-01 | IEC 62271-107:2019 | IEC 62271-111:2019 Wylaczniki, rozlaczniki i reklozery o Un = (3,6 - 400) kV, Circuit breakers, switches Wytrzymalosc elektryczna przy napieciu przemiennym:\nZakres:\n50 Hz do Up = 1000 kV\nPower frequency 50 Hz voltage PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 CSV | PN-EN IEC 62271-103:2024-04 | IEC 62271-103:2021 | PN-EN IEC 62271-100:2022-04 | PN-EN IEC 62271-100:2022-04/AC:2022-11 | PN-EN IEC 62271-100:2022-04/AC:2024-03 | IEC 62271-100:2021 | IEC 62271-100:2021/COR1:2021 | IEC 62271-100:2021/COR2:2022 | IEC 62271-100:2021/COR3:2024 | PN-EN IEC 62271-107:2020-01 | IEC 62271-107:2019 | IEC 62271-111:2019","categories":["other"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Circuit breakers, switch-disconnectors and reclosers with Un = (3,6 - 400) kV Electric strength at alternating voltage: 50 Hz up to Up = 1000 kV Power frequency 50 Hz voltage PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 CSV | PN-EN IEC 62271-103:2024-04 | IEC 62271-103:2021 | PN-EN IEC 62271-100:2022-04 | PN-EN IEC 62271-100:2022-04/AC:2022-11 | PN-EN IEC 62271-100:2022-04/AC:2024-03 | IEC 62271-100:2021 | IEC 62271-100:2021/COR1:2021 | IEC 62271-100:2021/COR2:2022 | IEC 62271-100:2021/COR3:2024 | PN-EN IEC 62271-107:2020-01 | IEC 62271-107:2019 | IEC 62271-111:2019","methodology_zh":"交流电压下的介电强度：","search_zh":"交流电压下的介电强度： PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 CSV | PN-EN IEC 62271-103:2024-04 | IEC 62271-103:2021 | PN-EN IEC 62271-100:2022-04 | PN-EN IEC 62271-100:2022-04/AC:2022-11 | PN-EN IEC 62271-100:2022-04/AC:2024-03 | IEC 62271-100:2021 | IEC 62271-100:2021/COR1:2021 | IEC 62271-100:2021/COR2:2022 | IEC 62271-100:2021/COR3:2024 | PN-EN IEC 62271-107:2020-01 | IEC 62271-107:2019 | IEC 62271-111:2019"},{"_id":"6a5dc9adf1c10c8ce825ac48","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Odłączniki o Un = (3,6 - 400) kV","test_object_en":"Disconnectors with Un = (3,6 - 400) kV","methodology":"Wytrzymałość elektryczna przy napięciu udarowym:","methodology_en":"Dielectric strength at impulse voltage:","parameters":[{"name":"piorunowym do Up = 4500 kV"},{"name":"łączeniowym do Up = 2800 kV"}],"parameters_en":[{"name":"lightning up to Up = 4500 kV"},{"name":"switching up to Up = 2800 kV"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość elektryczna przy napięciu udarowym:\nZakres:\npiorunowym do Up = 4500 kV\nłączeniowym do Up = 2800 kV","reference":"PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 CSV | PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | IEC 62271-102:2018+AMD1:2022 CSV","norm_bases":["PN-EN 60060-1:2011","IEC 60060-1:2025","PN-EN 60060-2:2011","IEC 60060-2:2025","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-1:2017+AMD1:2021 CSV","PN-EN IEC 62271-102:2018-10","PN-EN IEC 62271-102:2018-10/A1:2023-01","IEC 62271-102:2018+AMD1:2022 CSV"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odłączniki o Un = (3,6 - 400) kV Wytrzymałość elektryczna przy napięciu udarowym:\nZakres:\npiorunowym do Up = 4500 kV\nłączeniowym do Up = 2800 kV PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 CSV | PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | IEC 62271-102:2018+AMD1:2022 CSV Odlaczniki o Un = (3,6 - 400) kV Wytrzymalosc elektryczna przy napieciu udarowym:\nZakres:\npiorunowym do Up = 4500 kV\nlaczeniowym do Up = 2800 kV PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 CSV | PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | IEC 62271-102:2018+AMD1:2022 CSV","categories":["other"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Disconnectors with Un = (3,6 - 400) kV Dielectric strength at impulse voltage: lightning up to Up = 4500 kV switching up to Up = 2800 kV PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 CSV | PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | IEC 62271-102:2018+AMD1:2022 CSV","methodology_zh":"冲击电压下的介电强度：","parameters_zh":[{"name":"雷电冲击至 Up = 4500 kV"},{"name":"操作冲击至 Up = 2800 kV"}],"search_zh":"冲击电压下的介电强度： 雷电冲击至 Up = 4500 kV 操作冲击至 Up = 2800 kV PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 CSV | PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | IEC 62271-102:2018+AMD1:2022 CSV"},{"_id":"6a5dc9adf1c10c8ce825ac49","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Odłączniki o Un = (3,6 - 400) kV","test_object_en":"Disconnectors with Un = (3,6 - 400) kV","methodology":"Wytrzymałość elektryczna przy napięciu przemiennym:","methodology_en":"Electric strength at alternating voltage:","parameters":[{"name":"50 Hz do Up = 1000 kV"},{"name":"Power frequency 50 Hz voltage withstand"}],"parameters_en":[{"name":"50 Hz up to Up = 1000 kV"},{"name":"Power frequency 50 Hz voltage withstand"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość elektryczna przy napięciu przemiennym:\nZakres:\n50 Hz do Up = 1000 kV\nPower frequency 50 Hz voltage withstand","reference":"PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 CSV | PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | IEC 62271-102:2018+AMD1:2022 CSV","norm_bases":["PN-EN 60060-1:2011","IEC 60060-1:2025","PN-EN 60060-2:2011","IEC 60060-2:2025","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-1:2017+AMD1:2021 CSV","PN-EN IEC 62271-102:2018-10","PN-EN IEC 62271-102:2018-10/A1:2023-01","IEC 62271-102:2018+AMD1:2022 CSV"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odłączniki o Un = (3,6 - 400) kV Wytrzymałość elektryczna przy napięciu przemiennym:\nZakres:\n50 Hz do Up = 1000 kV\nPower frequency 50 Hz voltage withstand PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 CSV | PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | IEC 62271-102:2018+AMD1:2022 CSV Odlaczniki o Un = (3,6 - 400) kV Wytrzymalosc elektryczna przy napieciu przemiennym:\nZakres:\n50 Hz do Up = 1000 kV\nPower frequency 50 Hz voltage withstand PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 CSV | PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | IEC 62271-102:2018+AMD1:2022 CSV","categories":["other"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Disconnectors with Un = (3,6 - 400) kV Electric strength at alternating voltage: 50 Hz up to Up = 1000 kV Power frequency 50 Hz voltage withstand PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 CSV | PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | IEC 62271-102:2018+AMD1:2022 CSV","methodology_zh":"交流电压下的介电强度：","search_zh":"交流电压下的介电强度： PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 CSV | PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | IEC 62271-102:2018+AMD1:2022 CSV"},{"_id":"6a5dc9adf1c10c8ce825ac4a","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Odłączniki o Un = (3,6 - 400) kV","test_object_en":"Disconnectors with Un = (3,6 - 400) kV","methodology":"Poziom zakłóceń radioelektrycznych (RIV) i poziom wyładowań niezupełnych (PD): maksymalne Up = 400 kV","methodology_en":"Radio interference voltage level (RIV) and partial discharge level (PD): maximum Up = 400 kV","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Poziom zakłóceń radioelektrycznych (RIV) i poziom wyładowań niezupełnych (PD): maksymalne Up = 400 kV","reference":"PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 CISPR TR 18-2:2017 | PN-EN 60270:2003 | PN-EN 60270:2003/A1:2016-04 | IEC 60270:2025 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 CSV | PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | IEC 62271-102:2018+AMD1:2022 CSV","norm_bases":["PN-EN 60060-1:2011","IEC 60060-1:2025","PN-EN 60060-2:2011","IEC 60060-2:2025 CISPR TR 18-2:2017","PN-EN 60270:2003","PN-EN 60270:2003/A1:2016-04","IEC 60270:2025","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-1:2017+AMD1:2021 CSV","PN-EN IEC 62271-102:2018-10","PN-EN IEC 62271-102:2018-10/A1:2023-01","IEC 62271-102:2018+AMD1:2022 CSV"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odłączniki o Un = (3,6 - 400) kV Poziom zakłóceń radioelektrycznych (RIV) i poziom wyładowań niezupełnych (PD): maksymalne Up = 400 kV PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 CISPR TR 18-2:2017 | PN-EN 60270:2003 | PN-EN 60270:2003/A1:2016-04 | IEC 60270:2025 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 CSV | PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | IEC 62271-102:2018+AMD1:2022 CSV Odlaczniki o Un = (3,6 - 400) kV Poziom zaklocen radioelektrycznych (RIV) i poziom wyladowan niezupelnych (PD): maksymalne Up = 400 kV PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 CISPR TR 18-2:2017 | PN-EN 60270:2003 | PN-EN 60270:2003/A1:2016-04 | IEC 60270:2025 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 CSV | PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | IEC 62271-102:2018+AMD1:2022 CSV","categories":["other"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Disconnectors with Un = (3,6 - 400) kV Radio interference voltage level (RIV) and partial discharge level (PD): maximum Up = 400 kV PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 CISPR TR 18-2:2017 | PN-EN 60270:2003 | PN-EN 60270:2003/A1:2016-04 | IEC 60270:2025 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 CSV | PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | IEC 62271-102:2018+AMD1:2022 CSV","methodology_zh":"无线电干扰电压（RIV）与局部放电（PD）水平：最大 Up = 400 kV","search_zh":"无线电干扰电压（RIV）与局部放电（PD）水平：最大 Up = 400 kV PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 CISPR TR 18-2:2017 | PN-EN 60270:2003 | PN-EN 60270:2003/A1:2016-04 | IEC 60270:2025 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 CSV | PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | IEC 62271-102:2018+AMD1:2022 CSV"},{"_id":"6a5dc9adf1c10c8ce825ac4b","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Bezpieczniki topikowe wysokonapięciowe, High-voltage fuses","test_object_en":"High-voltage fuses","methodology":"Wytrzymałość elektryczna przy napięciu udarowym:","methodology_en":"Dielectric strength at impulse voltage:","parameters":[{"name":"piorunowym do Up = 4500 kV"}],"parameters_en":[{"name":"lightning up to Up = 4500 kV"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość elektryczna przy napięciu udarowym:\npiorunowym do Up = 4500 kV","reference":"PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN IEC 60282-1:2021-01 | IEC 60282-1:2020","norm_bases":["PN-EN 60060-1:2011","IEC 60060-1:2025","PN-EN 60060-2:2011","IEC 60060-2:2025","PN-EN IEC 60282-1:2021-01","IEC 60282-1:2020"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Bezpieczniki topikowe wysokonapięciowe, High-voltage fuses Wytrzymałość elektryczna przy napięciu udarowym:\npiorunowym do Up = 4500 kV PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN IEC 60282-1:2021-01 | IEC 60282-1:2020 Bezpieczniki topikowe wysokonapieciowe, High-voltage fuses Wytrzymalosc elektryczna przy napieciu udarowym:\npiorunowym do Up = 4500 kV PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN IEC 60282-1:2021-01 | IEC 60282-1:2020","categories":["other"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"High-voltage fuses Dielectric strength at impulse voltage: lightning up to Up = 4500 kV PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN IEC 60282-1:2021-01 | IEC 60282-1:2020","methodology_zh":"冲击电压下的介电强度：","parameters_zh":[{"name":"雷电冲击至 Up = 4500 kV"}],"search_zh":"冲击电压下的介电强度： 雷电冲击至 Up = 4500 kV PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN IEC 60282-1:2021-01 | IEC 60282-1:2020"},{"_id":"6a5dc9adf1c10c8ce825ac4c","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Bezpieczniki topikowe wysokonapięciowe, High-voltage fuses","test_object_en":"High-voltage fuses","methodology":"Próby napięciem przemiennym","methodology_en":"Alternating voltage tests","parameters":[{"name":"Zakres","range":"do 140 kV"}],"parameters_en":[{"name":"Range","range":"do 140 kV"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Próby napięciem przemiennym\nZakres do 140 kV","reference":"PN-EN 60269-1:2010 | PN-EN 60269-1:2010/A1:2012 | PN-EN 60269-1:2010/A2:2015-02 | IEC 60269-1:2024 | PN-EN IEC 60282-1:2021-01 | IEC 60282-1:2020","norm_bases":["PN-EN 60269-1:2010","PN-EN 60269-1:2010/A1:2012","PN-EN 60269-1:2010/A2:2015-02","IEC 60269-1:2024","PN-EN IEC 60282-1:2021-01","IEC 60282-1:2020"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Bezpieczniki topikowe wysokonapięciowe, High-voltage fuses Próby napięciem przemiennym\nZakres do 140 kV PN-EN 60269-1:2010 | PN-EN 60269-1:2010/A1:2012 | PN-EN 60269-1:2010/A2:2015-02 | IEC 60269-1:2024 | PN-EN IEC 60282-1:2021-01 | IEC 60282-1:2020 Bezpieczniki topikowe wysokonapieciowe, High-voltage fuses Proby napieciem przemiennym\nZakres do 140 kV PN-EN 60269-1:2010 | PN-EN 60269-1:2010/A1:2012 | PN-EN 60269-1:2010/A2:2015-02 | IEC 60269-1:2024 | PN-EN IEC 60282-1:2021-01 | IEC 60282-1:2020","categories":["other"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"High-voltage fuses Alternating voltage tests Range PN-EN 60269-1:2010 | PN-EN 60269-1:2010/A1:2012 | PN-EN 60269-1:2010/A2:2015-02 | IEC 60269-1:2024 | PN-EN IEC 60282-1:2021-01 | IEC 60282-1:2020","parameters_zh":[{"name":"范围","range":"do 140 kV"}],"search_zh":"范围 PN-EN 60269-1:2010 | PN-EN 60269-1:2010/A1:2012 | PN-EN 60269-1:2010/A2:2015-02 | IEC 60269-1:2024 | PN-EN IEC 60282-1:2021-01 | IEC 60282-1:2020"},{"_id":"6a5dc9adf1c10c8ce825ac4d","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Przekładniki prądowe, napięciowe i kombinowane o Un = (3,6 - 400) kV","test_object_en":"Current, voltage and combined instrument transformers with Un = (3,6 - 400) kV","methodology":"Wytrzymałość elektryczna przy napięciu udarowym:","methodology_en":"Dielectric strength at impulse voltage:","parameters":[{"name":"piorunowym do Up = 4500 kV"},{"name":"łączeniowym do Up = 2800 kV"}],"parameters_en":[{"name":"lightning up to Up = 4500 kV"},{"name":"switching up to Up = 2800 kV"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość elektryczna przy napięciu udarowym:\nZakres:\npiorunowym do Up = 4500 kV\nłączeniowym do Up = 2800 kV","reference":"PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 61869-2:2013-06 | IEC 61869-2:2012 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013 | IEC 61869-4:2013/COR1:2014 | PN-EN 61869-5:2011 | PN-EN 61869-5:2011/AC1:2016-03 | IEC 61869-5:2011 | IEC 61869-5:2011/COR1:2015 | PN-EN 61869-3:2011 | IEC 61869-3:2011","norm_bases":["PN-EN 60060-1:2011","IEC 60060-1:2025","PN-EN 60060-2:2011","IEC 60060-2:2025","PN-EN 61869-2:2013-06","IEC 61869-2:2012","PN-EN 61869-4:2014-09","IEC 61869-4:2013","IEC 61869-4:2013/COR1:2014","PN-EN 61869-5:2011","PN-EN 61869-5:2011/AC1:2016-03","IEC 61869-5:2011","IEC 61869-5:2011/COR1:2015","PN-EN 61869-3:2011","IEC 61869-3:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przekładniki prądowe, napięciowe i kombinowane o Un = (3,6 - 400) kV Wytrzymałość elektryczna przy napięciu udarowym:\nZakres:\npiorunowym do Up = 4500 kV\nłączeniowym do Up = 2800 kV PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 61869-2:2013-06 | IEC 61869-2:2012 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013 | IEC 61869-4:2013/COR1:2014 | PN-EN 61869-5:2011 | PN-EN 61869-5:2011/AC1:2016-03 | IEC 61869-5:2011 | IEC 61869-5:2011/COR1:2015 | PN-EN 61869-3:2011 | IEC 61869-3:2011 Przekladniki pradowe, napieciowe i kombinowane o Un = (3,6 - 400) kV Wytrzymalosc elektryczna przy napieciu udarowym:\nZakres:\npiorunowym do Up = 4500 kV\nlaczeniowym do Up = 2800 kV PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 61869-2:2013-06 | IEC 61869-2:2012 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013 | IEC 61869-4:2013/COR1:2014 | PN-EN 61869-5:2011 | PN-EN 61869-5:2011/AC1:2016-03 | IEC 61869-5:2011 | IEC 61869-5:2011/COR1:2015 | PN-EN 61869-3:2011 | IEC 61869-3:2011","categories":["other"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Current, voltage and combined instrument transformers with Un = (3,6 - 400) kV Dielectric strength at impulse voltage: lightning up to Up = 4500 kV switching up to Up = 2800 kV PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 61869-2:2013-06 | IEC 61869-2:2012 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013 | IEC 61869-4:2013/COR1:2014 | PN-EN 61869-5:2011 | PN-EN 61869-5:2011/AC1:2016-03 | IEC 61869-5:2011 | IEC 61869-5:2011/COR1:2015 | PN-EN 61869-3:2011 | IEC 61869-3:2011","methodology_zh":"冲击电压下的介电强度：","parameters_zh":[{"name":"雷电冲击至 Up = 4500 kV"},{"name":"操作冲击至 Up = 2800 kV"}],"search_zh":"Un = (3,6 - 400) kV 的电流、电压与组合式互感器 冲击电压下的介电强度： 雷电冲击至 Up = 4500 kV 操作冲击至 Up = 2800 kV PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 61869-2:2013-06 | IEC 61869-2:2012 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013 | IEC 61869-4:2013/COR1:2014 | PN-EN 61869-5:2011 | PN-EN 61869-5:2011/AC1:2016-03 | IEC 61869-5:2011 | IEC 61869-5:2011/COR1:2015 | PN-EN 61869-3:2011 | IEC 61869-3:2011","test_object_zh":"Un = (3,6 - 400) kV 的电流、电压与组合式互感器"},{"_id":"6a5dc9adf1c10c8ce825ac4e","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Przekładniki prądowe, napięciowe i kombinowane o Un = (3,6 - 400) kV","test_object_en":"Current, voltage and combined instrument transformers with Un = (3,6 - 400) kV","methodology":"Wytrzymałość elektryczna przy napięciu przemiennym: 50 Hz do Up = 1000 kV","methodology_en":"Electric strength at alternating voltage: 50 Hz up to Up = 1000 kV","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość elektryczna przy napięciu przemiennym: 50 Hz do Up = 1000 kV","reference":"PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 61869-2:2013-06 | IEC 61869-2:2012 | PN-EN 61869-5:2011 | PN-EN 61869-5:2011/AC1:2016-03 | IEC 61869-5:2011 | IEC 61869-5:2011/COR1:2015","norm_bases":["PN-EN 60060-1:2011","IEC 60060-1:2025","PN-EN 60060-2:2011","IEC 60060-2:2025","PN-EN 61869-2:2013-06","IEC 61869-2:2012","PN-EN 61869-5:2011","PN-EN 61869-5:2011/AC1:2016-03","IEC 61869-5:2011","IEC 61869-5:2011/COR1:2015"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przekładniki prądowe, napięciowe i kombinowane o Un = (3,6 - 400) kV Wytrzymałość elektryczna przy napięciu przemiennym: 50 Hz do Up = 1000 kV PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 61869-2:2013-06 | IEC 61869-2:2012 | PN-EN 61869-5:2011 | PN-EN 61869-5:2011/AC1:2016-03 | IEC 61869-5:2011 | IEC 61869-5:2011/COR1:2015 Przekladniki pradowe, napieciowe i kombinowane o Un = (3,6 - 400) kV Wytrzymalosc elektryczna przy napieciu przemiennym: 50 Hz do Up = 1000 kV PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 61869-2:2013-06 | IEC 61869-2:2012 | PN-EN 61869-5:2011 | PN-EN 61869-5:2011/AC1:2016-03 | IEC 61869-5:2011 | IEC 61869-5:2011/COR1:2015","categories":["other"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Current, voltage and combined instrument transformers with Un = (3,6 - 400) kV Electric strength at alternating voltage: 50 Hz up to Up = 1000 kV PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 61869-2:2013-06 | IEC 61869-2:2012 | PN-EN 61869-5:2011 | PN-EN 61869-5:2011/AC1:2016-03 | IEC 61869-5:2011 | IEC 61869-5:2011/COR1:2015","methodology_zh":"交流电压下的介电强度：50 Hz 至 Up = 1000 kV","search_zh":"Un = (3,6 - 400) kV 的电流、电压与组合式互感器 交流电压下的介电强度：50 Hz 至 Up = 1000 kV PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 61869-2:2013-06 | IEC 61869-2:2012 | PN-EN 61869-5:2011 | PN-EN 61869-5:2011/AC1:2016-03 | IEC 61869-5:2011 | IEC 61869-5:2011/COR1:2015","test_object_zh":"Un = (3,6 - 400) kV 的电流、电压与组合式互感器"},{"_id":"6a5dc9adf1c10c8ce825ac4f","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Przekładniki prądowe, napięciowe i kombinowane o Un = (3,6 - 400) kV","test_object_en":"Current, voltage and combined instrument transformers with Un = (3,6 - 400) kV","methodology":"Poziom zakłóceń radioelektrycznych (RIV) i poziom wyładowań niezupełnych (PD): maksymalne Up = 400 kV","methodology_en":"Radio interference voltage level (RIV) and partial discharge level (PD): maximum Up = 400 kV","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Poziom zakłóceń radioelektrycznych (RIV) i poziom wyładowań niezupełnych (PD): maksymalne Up = 400 kV","reference":"PN-EN IEC 61869-1:2025-10 | IEC 61869-1:2023 | PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 61869-2:2013-06 | IEC 61869-2:2012 | PN-EN 61869-3:2011 | IEC 61869-3:2011 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013 | IEC 61869-4:2013/COR1:2014 | PN-EN 61869-5:2011 | PN-EN 61869-5:2011/AC1:2016-03 | IEC 61869-5:2011 | IEC 61869-5:2011/COR1:2015 CISPR TR 18-2:2017 | PN-EN 60270:2003 | PN-EN 60270:2003/A1:2016-04 | IEC 60270:2025","norm_bases":["PN-EN IEC 61869-1:2025-10","IEC 61869-1:2023","PN-EN 60060-1:2011","IEC 60060-1:2025","PN-EN 60060-2:2011","IEC 60060-2:2025","PN-EN 61869-2:2013-06","IEC 61869-2:2012","PN-EN 61869-3:2011","IEC 61869-3:2011","PN-EN 61869-4:2014-09","IEC 61869-4:2013","IEC 61869-4:2013/COR1:2014","PN-EN 61869-5:2011","PN-EN 61869-5:2011/AC1:2016-03","IEC 61869-5:2011","IEC 61869-5:2011/COR1:2015 CISPR TR 18-2:2017","PN-EN 60270:2003","PN-EN 60270:2003/A1:2016-04","IEC 60270:2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przekładniki prądowe, napięciowe i kombinowane o Un = (3,6 - 400) kV Poziom zakłóceń radioelektrycznych (RIV) i poziom wyładowań niezupełnych (PD): maksymalne Up = 400 kV PN-EN IEC 61869-1:2025-10 | IEC 61869-1:2023 | PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 61869-2:2013-06 | IEC 61869-2:2012 | PN-EN 61869-3:2011 | IEC 61869-3:2011 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013 | IEC 61869-4:2013/COR1:2014 | PN-EN 61869-5:2011 | PN-EN 61869-5:2011/AC1:2016-03 | IEC 61869-5:2011 | IEC 61869-5:2011/COR1:2015 CISPR TR 18-2:2017 | PN-EN 60270:2003 | PN-EN 60270:2003/A1:2016-04 | IEC 60270:2025 Przekladniki pradowe, napieciowe i kombinowane o Un = (3,6 - 400) kV Poziom zaklocen radioelektrycznych (RIV) i poziom wyladowan niezupelnych (PD): maksymalne Up = 400 kV PN-EN IEC 61869-1:2025-10 | IEC 61869-1:2023 | PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 61869-2:2013-06 | IEC 61869-2:2012 | PN-EN 61869-3:2011 | IEC 61869-3:2011 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013 | IEC 61869-4:2013/COR1:2014 | PN-EN 61869-5:2011 | PN-EN 61869-5:2011/AC1:2016-03 | IEC 61869-5:2011 | IEC 61869-5:2011/COR1:2015 CISPR TR 18-2:2017 | PN-EN 60270:2003 | PN-EN 60270:2003/A1:2016-04 | IEC 60270:2025","categories":["other"],"row_index":21,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Current, voltage and combined instrument transformers with Un = (3,6 - 400) kV Radio interference voltage level (RIV) and partial discharge level (PD): maximum Up = 400 kV PN-EN IEC 61869-1:2025-10 | IEC 61869-1:2023 | PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 61869-2:2013-06 | IEC 61869-2:2012 | PN-EN 61869-3:2011 | IEC 61869-3:2011 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013 | IEC 61869-4:2013/COR1:2014 | PN-EN 61869-5:2011 | PN-EN 61869-5:2011/AC1:2016-03 | IEC 61869-5:2011 | IEC 61869-5:2011/COR1:2015 CISPR TR 18-2:2017 | PN-EN 60270:2003 | PN-EN 60270:2003/A1:2016-04 | IEC 60270:2025","methodology_zh":"无线电干扰电压（RIV）与局部放电（PD）水平：最大 Up = 400 kV","search_zh":"Un = (3,6 - 400) kV 的电流、电压与组合式互感器 无线电干扰电压（RIV）与局部放电（PD）水平：最大 Up = 400 kV PN-EN IEC 61869-1:2025-10 | IEC 61869-1:2023 | PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 61869-2:2013-06 | IEC 61869-2:2012 | PN-EN 61869-3:2011 | IEC 61869-3:2011 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013 | IEC 61869-4:2013/COR1:2014 | PN-EN 61869-5:2011 | PN-EN 61869-5:2011/AC1:2016-03 | IEC 61869-5:2011 | IEC 61869-5:2011/COR1:2015 CISPR TR 18-2:2017 | PN-EN 60270:2003 | PN-EN 60270:2003/A1:2016-04 | IEC 60270:2025","test_object_zh":"Un = (3,6 - 400) kV 的电流、电压与组合式互感器"},{"_id":"6a5dc9adf1c10c8ce825ac50","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Przekładniki prądowe, napięciowe i kombinowane o Un = (3,6 - 400) kV","test_object_en":"Current, voltage and combined instrument transformers with Un = (3,6 - 400) kV","methodology":"Błąd prądowy i kątowy przekładników","methodology_en":"Current error and phase displacement of instrument transformers","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Błąd prądowy i kątowy przekładników","reference":"PN-EN 61869-2:2013-06 | PN-EN IEC 61869-1:2025-10 | IEC 61869-2:2012 | IEC 61869-1:2023","norm_bases":["PN-EN 61869-2:2013-06","PN-EN IEC 61869-1:2025-10","IEC 61869-2:2012","IEC 61869-1:2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przekładniki prądowe, napięciowe i kombinowane o Un = (3,6 - 400) kV Błąd prądowy i kątowy przekładników PN-EN 61869-2:2013-06 | PN-EN IEC 61869-1:2025-10 | IEC 61869-2:2012 | IEC 61869-1:2023 Przekladniki pradowe, napieciowe i kombinowane o Un = (3,6 - 400) kV Blad pradowy i katowy przekladnikow PN-EN 61869-2:2013-06 | PN-EN IEC 61869-1:2025-10 | IEC 61869-2:2012 | IEC 61869-1:2023","categories":["other"],"row_index":22,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Current, voltage and combined instrument transformers with Un = (3,6 - 400) kV Current error and phase displacement of instrument transformers PN-EN 61869-2:2013-06 | PN-EN IEC 61869-1:2025-10 | IEC 61869-2:2012 | IEC 61869-1:2023","search_zh":"Un = (3,6 - 400) kV 的电流、电压与组合式互感器 PN-EN 61869-2:2013-06 | PN-EN IEC 61869-1:2025-10 | IEC 61869-2:2012 | IEC 61869-1:2023","test_object_zh":"Un = (3,6 - 400) kV 的电流、电压与组合式互感器"},{"_id":"6a5dc9adf1c10c8ce825ac51","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Transformatory i dławiki o Un = (3,6 - 420) kV","test_object_en":"Transformers and reactors with Un = (3,6 - 420) kV","methodology":"Wytrzymałość elektryczna przy napięciu udarowym:","methodology_en":"Dielectric strength at impulse voltage:","parameters":[{"name":"piorunowym do Up = 4500 kV"},{"name":"łączeniowym do Up = 2800 kV"}],"parameters_en":[{"name":"lightning up to Up = 4500 kV"},{"name":"switching up to Up = 2800 kV"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość elektryczna przy napięciu udarowym:\nZakres:\npiorunowym do Up = 4500 kV\nłączeniowym do Up = 2800 kV","reference":"PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 60076-1:2011 | IEC 60076-1:2011 | PN-EN 60076-3:2014 | PN-EN 60076-3:2014-02/A1:2018-09 | IEC 60076-3:2013 | IEC 60076-3:2013/AMD1:2018 | PN-EN 60076-4:2004 | IEC 60076-4:2002 | PN-EN IEC 60076-11:2019-01 SFS 2646:1987 | PN-EN 60076-6:2008 | IEC 60076-6:2007 | IEC 60076-11:2018","norm_bases":["PN-EN 60060-1:2011","IEC 60060-1:2025","PN-EN 60060-2:2011","IEC 60060-2:2025","PN-EN 60076-1:2011","IEC 60076-1:2011","PN-EN 60076-3:2014","PN-EN 60076-3:2014-02/A1:2018-09","IEC 60076-3:2013","IEC 60076-3:2013/AMD1:2018","PN-EN 60076-4:2004","IEC 60076-4:2002","PN-EN IEC 60076-11:2019-01 SFS 2646:1987","PN-EN 60076-6:2008","IEC 60076-6:2007","IEC 60076-11:2018"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Transformatory i dławiki o Un = (3,6 - 420) kV Wytrzymałość elektryczna przy napięciu udarowym:\nZakres:\npiorunowym do Up = 4500 kV\nłączeniowym do Up = 2800 kV PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 60076-1:2011 | IEC 60076-1:2011 | PN-EN 60076-3:2014 | PN-EN 60076-3:2014-02/A1:2018-09 | IEC 60076-3:2013 | IEC 60076-3:2013/AMD1:2018 | PN-EN 60076-4:2004 | IEC 60076-4:2002 | PN-EN IEC 60076-11:2019-01 SFS 2646:1987 | PN-EN 60076-6:2008 | IEC 60076-6:2007 | IEC 60076-11:2018 Transformatory i dlawiki o Un = (3,6 - 420) kV Wytrzymalosc elektryczna przy napieciu udarowym:\nZakres:\npiorunowym do Up = 4500 kV\nlaczeniowym do Up = 2800 kV PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 60076-1:2011 | IEC 60076-1:2011 | PN-EN 60076-3:2014 | PN-EN 60076-3:2014-02/A1:2018-09 | IEC 60076-3:2013 | IEC 60076-3:2013/AMD1:2018 | PN-EN 60076-4:2004 | IEC 60076-4:2002 | PN-EN IEC 60076-11:2019-01 SFS 2646:1987 | PN-EN 60076-6:2008 | IEC 60076-6:2007 | IEC 60076-11:2018","categories":["other"],"row_index":23,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Transformers and reactors with Un = (3,6 - 420) kV Dielectric strength at impulse voltage: lightning up to Up = 4500 kV switching up to Up = 2800 kV PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 60076-1:2011 | IEC 60076-1:2011 | PN-EN 60076-3:2014 | PN-EN 60076-3:2014-02/A1:2018-09 | IEC 60076-3:2013 | IEC 60076-3:2013/AMD1:2018 | PN-EN 60076-4:2004 | IEC 60076-4:2002 | PN-EN IEC 60076-11:2019-01 SFS 2646:1987 | PN-EN 60076-6:2008 | IEC 60076-6:2007 | IEC 60076-11:2018","methodology_zh":"冲击电压下的介电强度：","parameters_zh":[{"name":"雷电冲击至 Up = 4500 kV"},{"name":"操作冲击至 Up = 2800 kV"}],"search_zh":"冲击电压下的介电强度： 雷电冲击至 Up = 4500 kV 操作冲击至 Up = 2800 kV PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 60076-1:2011 | IEC 60076-1:2011 | PN-EN 60076-3:2014 | PN-EN 60076-3:2014-02/A1:2018-09 | IEC 60076-3:2013 | IEC 60076-3:2013/AMD1:2018 | PN-EN 60076-4:2004 | IEC 60076-4:2002 | PN-EN IEC 60076-11:2019-01 SFS 2646:1987 | PN-EN 60076-6:2008 | IEC 60076-6:2007 | IEC 60076-11:2018"},{"_id":"6a5dc9adf1c10c8ce825ac52","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Transformatory i dławiki o Un = (3,6 - 420) kV","test_object_en":"Transformers and reactors with Un = (3,6 - 420) kV","methodology":"Wytrzymałość elektryczna przy napięciu przemiennym: 50 Hz do Up = 1000 kV","methodology_en":"Electric strength at alternating voltage: 50 Hz up to Up = 1000 kV","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość elektryczna przy napięciu przemiennym: 50 Hz do Up = 1000 kV","reference":"PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 60076-1:2011 | IEC 60076-1:2011 | PN-EN 60076-3:2014 | PN-EN 60076-3:2014-02/A1:2018-09 | IEC 60076-3:2013 | IEC 60076-3:2013/AMD1:2018 | PN-EN 60076-6:2008 | IEC 60076-6:2007","norm_bases":["PN-EN 60060-1:2011","IEC 60060-1:2025","PN-EN 60060-2:2011","IEC 60060-2:2025","PN-EN 60076-1:2011","IEC 60076-1:2011","PN-EN 60076-3:2014","PN-EN 60076-3:2014-02/A1:2018-09","IEC 60076-3:2013","IEC 60076-3:2013/AMD1:2018","PN-EN 60076-6:2008","IEC 60076-6:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Transformatory i dławiki o Un = (3,6 - 420) kV Wytrzymałość elektryczna przy napięciu przemiennym: 50 Hz do Up = 1000 kV PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 60076-1:2011 | IEC 60076-1:2011 | PN-EN 60076-3:2014 | PN-EN 60076-3:2014-02/A1:2018-09 | IEC 60076-3:2013 | IEC 60076-3:2013/AMD1:2018 | PN-EN 60076-6:2008 | IEC 60076-6:2007 Transformatory i dlawiki o Un = (3,6 - 420) kV Wytrzymalosc elektryczna przy napieciu przemiennym: 50 Hz do Up = 1000 kV PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 60076-1:2011 | IEC 60076-1:2011 | PN-EN 60076-3:2014 | PN-EN 60076-3:2014-02/A1:2018-09 | IEC 60076-3:2013 | IEC 60076-3:2013/AMD1:2018 | PN-EN 60076-6:2008 | IEC 60076-6:2007","categories":["other"],"row_index":24,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Transformers and reactors with Un = (3,6 - 420) kV Electric strength at alternating voltage: 50 Hz up to Up = 1000 kV PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 60076-1:2011 | IEC 60076-1:2011 | PN-EN 60076-3:2014 | PN-EN 60076-3:2014-02/A1:2018-09 | IEC 60076-3:2013 | IEC 60076-3:2013/AMD1:2018 | PN-EN 60076-6:2008 | IEC 60076-6:2007","methodology_zh":"交流电压下的介电强度：50 Hz 至 Up = 1000 kV","search_zh":"交流电压下的介电强度：50 Hz 至 Up = 1000 kV PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 60076-1:2011 | IEC 60076-1:2011 | PN-EN 60076-3:2014 | PN-EN 60076-3:2014-02/A1:2018-09 | IEC 60076-3:2013 | IEC 60076-3:2013/AMD1:2018 | PN-EN 60076-6:2008 | IEC 60076-6:2007"},{"_id":"6a5dc9adf1c10c8ce825ac53","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Odgromniki i ograniczniki przepięć o Un = (3,6 - 400) kV","test_object_en":"Lightning arresters and surge arresters with Un = (3,6 - 400) kV","methodology":"Wytrzymałość elektryczna przy napięciu udarowym:","methodology_en":"Dielectric strength at impulse voltage:","parameters":[{"name":"piorunowym do Up = 4500 kV"},{"name":"łączeniowym do Up = 2800 kV"}],"parameters_en":[{"name":"lightning up to Up = 4500 kV"},{"name":"switching up to Up = 2800 kV"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość elektryczna przy napięciu udarowym:\nZakres:\npiorunowym do Up = 4500 kV\nłączeniowym do Up = 2800 kV","reference":"PN-EN 60060-1:2011 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 60099-4:2015-01 | IEC 60099-4:2014","norm_bases":["PN-EN 60060-1:2011","PN-EN 60060-2:2011","IEC 60060-2:2025","PN-EN 60099-4:2015-01","IEC 60099-4:2014"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odgromniki i ograniczniki przepięć o Un = (3,6 - 400) kV Wytrzymałość elektryczna przy napięciu udarowym:\nZakres:\npiorunowym do Up = 4500 kV\nłączeniowym do Up = 2800 kV PN-EN 60060-1:2011 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 60099-4:2015-01 | IEC 60099-4:2014 Odgromniki i ograniczniki przepiec o Un = (3,6 - 400) kV Wytrzymalosc elektryczna przy napieciu udarowym:\nZakres:\npiorunowym do Up = 4500 kV\nlaczeniowym do Up = 2800 kV PN-EN 60060-1:2011 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 60099-4:2015-01 | IEC 60099-4:2014","categories":["other"],"row_index":25,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Lightning arresters and surge arresters with Un = (3,6 - 400) kV Dielectric strength at impulse voltage: lightning up to Up = 4500 kV switching up to Up = 2800 kV PN-EN 60060-1:2011 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 60099-4:2015-01 | IEC 60099-4:2014","methodology_zh":"冲击电压下的介电强度：","parameters_zh":[{"name":"雷电冲击至 Up = 4500 kV"},{"name":"操作冲击至 Up = 2800 kV"}],"search_zh":"Un = (3,6 - 400) kV 的避雷器与电涌保护器 冲击电压下的介电强度： 雷电冲击至 Up = 4500 kV 操作冲击至 Up = 2800 kV PN-EN 60060-1:2011 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 60099-4:2015-01 | IEC 60099-4:2014","test_object_zh":"Un = (3,6 - 400) kV 的避雷器与电涌保护器"},{"_id":"6a5dc9adf1c10c8ce825ac54","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Odgromniki i ograniczniki przepięć o Un = (3,6 - 400) kV","test_object_en":"Lightning arresters and surge arresters with Un = (3,6 - 400) kV","methodology":"Wytrzymałość elektryczna przy napięciu przemiennym: 50 Hz do Up = 1000 kV","methodology_en":"Electric strength at alternating voltage: 50 Hz up to Up = 1000 kV","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość elektryczna przy napięciu przemiennym: 50 Hz do Up = 1000 kV","reference":"PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 60099-4:2015-01 | IEC 60099-4:2014","norm_bases":["PN-EN 60060-1:2011","IEC 60060-1:2025","PN-EN 60060-2:2011","IEC 60060-2:2025","PN-EN 60099-4:2015-01","IEC 60099-4:2014"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odgromniki i ograniczniki przepięć o Un = (3,6 - 400) kV Wytrzymałość elektryczna przy napięciu przemiennym: 50 Hz do Up = 1000 kV PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 60099-4:2015-01 | IEC 60099-4:2014 Odgromniki i ograniczniki przepiec o Un = (3,6 - 400) kV Wytrzymalosc elektryczna przy napieciu przemiennym: 50 Hz do Up = 1000 kV PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 60099-4:2015-01 | IEC 60099-4:2014","categories":["other"],"row_index":26,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Lightning arresters and surge arresters with Un = (3,6 - 400) kV Electric strength at alternating voltage: 50 Hz up to Up = 1000 kV PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 60099-4:2015-01 | IEC 60099-4:2014","methodology_zh":"交流电压下的介电强度：50 Hz 至 Up = 1000 kV","search_zh":"Un = (3,6 - 400) kV 的避雷器与电涌保护器 交流电压下的介电强度：50 Hz 至 Up = 1000 kV PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 60099-4:2015-01 | IEC 60099-4:2014","test_object_zh":"Un = (3,6 - 400) kV 的避雷器与电涌保护器"},{"_id":"6a5dc9adf1c10c8ce825ac55","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Odgromniki i ograniczniki przepięć o Un = (3,6 - 400) kV","test_object_en":"Lightning arresters and surge arresters with Un = (3,6 - 400) kV","methodology":"Poziom zakłóceń radioelektrycznych (RIV) i poziom wyładowań niezupełnych (PD): maksymalne Up = 400 kV","methodology_en":"Radio interference voltage level (RIV) and partial discharge level (PD): maximum Up = 400 kV","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Poziom zakłóceń radioelektrycznych (RIV) i poziom wyładowań niezupełnych (PD): maksymalne Up = 400 kV","reference":"PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 CISPR TR 18-2:2017 | PN-EN 60270:2003 | PN-EN 60270:2003/A1:2016-04 | IEC 60270:2025","norm_bases":["PN-EN 60060-1:2011","IEC 60060-1:2025","PN-EN 60060-2:2011","IEC 60060-2:2025 CISPR TR 18-2:2017","PN-EN 60270:2003","PN-EN 60270:2003/A1:2016-04","IEC 60270:2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odgromniki i ograniczniki przepięć o Un = (3,6 - 400) kV Poziom zakłóceń radioelektrycznych (RIV) i poziom wyładowań niezupełnych (PD): maksymalne Up = 400 kV PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 CISPR TR 18-2:2017 | PN-EN 60270:2003 | PN-EN 60270:2003/A1:2016-04 | IEC 60270:2025 Odgromniki i ograniczniki przepiec o Un = (3,6 - 400) kV Poziom zaklocen radioelektrycznych (RIV) i poziom wyladowan niezupelnych (PD): maksymalne Up = 400 kV PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 CISPR TR 18-2:2017 | PN-EN 60270:2003 | PN-EN 60270:2003/A1:2016-04 | IEC 60270:2025","categories":["other"],"row_index":27,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Lightning arresters and surge arresters with Un = (3,6 - 400) kV Radio interference voltage level (RIV) and partial discharge level (PD): maximum Up = 400 kV PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 CISPR TR 18-2:2017 | PN-EN 60270:2003 | PN-EN 60270:2003/A1:2016-04 | IEC 60270:2025","methodology_zh":"无线电干扰电压（RIV）与局部放电（PD）水平：最大 Up = 400 kV","search_zh":"Un = (3,6 - 400) kV 的避雷器与电涌保护器 无线电干扰电压（RIV）与局部放电（PD）水平：最大 Up = 400 kV PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 CISPR TR 18-2:2017 | PN-EN 60270:2003 | PN-EN 60270:2003/A1:2016-04 | IEC 60270:2025","test_object_zh":"Un = (3,6 - 400) kV 的避雷器与电涌保护器"},{"_id":"6a5dc9adf1c10c8ce825ac56","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Odgromniki i ograniczniki przepięć o Un = (3,6 - 400) kV","test_object_en":"Lightning arresters and surge arresters with Un = (3,6 - 400) kV","methodology":"Odporność na wyładowania pełzne i erozję, próba w mgle solnej: do Up = 100kV","methodology_en":"Resistance to tracking and erosion, salt fog test: up to Up = 100kV","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na wyładowania pełzne i erozję, próba w mgle solnej: do Up = 100kV","reference":"PN-EN 60099-4:2015-01 | IEC 60099-4:2014","norm_bases":["PN-EN 60099-4:2015-01","IEC 60099-4:2014"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odgromniki i ograniczniki przepięć o Un = (3,6 - 400) kV Odporność na wyładowania pełzne i erozję, próba w mgle solnej: do Up = 100kV PN-EN 60099-4:2015-01 | IEC 60099-4:2014 Odgromniki i ograniczniki przepiec o Un = (3,6 - 400) kV Odpornosc na wyladowania pelzne i erozje, proba w mgle solnej: do Up = 100kV PN-EN 60099-4:2015-01 | IEC 60099-4:2014","categories":["other"],"row_index":28,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Lightning arresters and surge arresters with Un = (3,6 - 400) kV Resistance to tracking and erosion, salt fog test: up to Up = 100kV PN-EN 60099-4:2015-01 | IEC 60099-4:2014","search_zh":"Un = (3,6 - 400) kV 的避雷器与电涌保护器 PN-EN 60099-4:2015-01 | IEC 60099-4:2014","test_object_zh":"Un = (3,6 - 400) kV 的避雷器与电涌保护器"},{"_id":"6a5dc9adf1c10c8ce825ac57","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Kable i osprzęt kablowy o Un = (3,6 - 245) kV","test_object_en":"Cables and cable accessories with Un = (3,6 - 245) kV","methodology":"Wytrzymałość elektryczna przy napięciu udarowym:","methodology_en":"Dielectric strength at impulse voltage:","parameters":[{"name":"piorunowym do Up = 4500 kV"},{"name":"łączeniowym do Up = 2800 kV"}],"parameters_en":[{"name":"lightning up to Up = 4500 kV"},{"name":"switching up to Up = 2800 kV"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość elektryczna przy napięciu udarowym:\nZakres:\npiorunowym do Up = 4500 kV\nłączeniowym do Up = 2800 kV","reference":"PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN IEC 60230:2018-06 | IEC 60230:2018+AMD1:2021 CSV | PN-EN 61442:2005 | PN-EN IEC 61442:2025-08 | IEC 61442:2023 | IEC 60055-1:1997+AMD1:2005 CSV | IEC 60502-1:2021 | IEC 60502-2:2014 | IEC 60502-2:2014/AMD1:2024 | IEC 60502-4:2023 | IEC 60840:2020 | IEC 60840:2020/COR1:2021 | IEC 60840:2020/AMD1:2023 | IEC 62067:2022 | PN-HD 621 S1:2003 | PN-HD 632 S3:2017-03 | PN-HD 629-1-S3:2019-10 | PN-HD 629.2 S2:2006 | PN-HD 629.2 S2:2006/A1:2008","norm_bases":["PN-EN 60060-1:2011","IEC 60060-1:2025","PN-EN 60060-2:2011","IEC 60060-2:2025","PN-EN IEC 60230:2018-06","IEC 60230:2018+AMD1:2021 CSV","PN-EN 61442:2005","PN-EN IEC 61442:2025-08","IEC 61442:2023","IEC 60055-1:1997+AMD1:2005 CSV","IEC 60502-1:2021","IEC 60502-2:2014","IEC 60502-2:2014/AMD1:2024","IEC 60502-4:2023","IEC 60840:2020","IEC 60840:2020/COR1:2021","IEC 60840:2020/AMD1:2023","IEC 62067:2022","PN-HD 621 S1:2003","PN-HD 632 S3:2017-03","PN-HD 629-1-S3:2019-10","PN-HD 629.2 S2:2006","PN-HD 629.2 S2:2006/A1:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable i osprzęt kablowy o Un = (3,6 - 245) kV Wytrzymałość elektryczna przy napięciu udarowym:\nZakres:\npiorunowym do Up = 4500 kV\nłączeniowym do Up = 2800 kV PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN IEC 60230:2018-06 | IEC 60230:2018+AMD1:2021 CSV | PN-EN 61442:2005 | PN-EN IEC 61442:2025-08 | IEC 61442:2023 | IEC 60055-1:1997+AMD1:2005 CSV | IEC 60502-1:2021 | IEC 60502-2:2014 | IEC 60502-2:2014/AMD1:2024 | IEC 60502-4:2023 | IEC 60840:2020 | IEC 60840:2020/COR1:2021 | IEC 60840:2020/AMD1:2023 | IEC 62067:2022 | PN-HD 621 S1:2003 | PN-HD 632 S3:2017-03 | PN-HD 629-1-S3:2019-10 | PN-HD 629.2 S2:2006 | PN-HD 629.2 S2:2006/A1:2008 Kable i osprzet kablowy o Un = (3,6 - 245) kV Wytrzymalosc elektryczna przy napieciu udarowym:\nZakres:\npiorunowym do Up = 4500 kV\nlaczeniowym do Up = 2800 kV PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN IEC 60230:2018-06 | IEC 60230:2018+AMD1:2021 CSV | PN-EN 61442:2005 | PN-EN IEC 61442:2025-08 | IEC 61442:2023 | IEC 60055-1:1997+AMD1:2005 CSV | IEC 60502-1:2021 | IEC 60502-2:2014 | IEC 60502-2:2014/AMD1:2024 | IEC 60502-4:2023 | IEC 60840:2020 | IEC 60840:2020/COR1:2021 | IEC 60840:2020/AMD1:2023 | IEC 62067:2022 | PN-HD 621 S1:2003 | PN-HD 632 S3:2017-03 | PN-HD 629-1-S3:2019-10 | PN-HD 629.2 S2:2006 | PN-HD 629.2 S2:2006/A1:2008","categories":["other"],"row_index":29,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables and cable accessories with Un = (3,6 - 245) kV Dielectric strength at impulse voltage: lightning up to Up = 4500 kV switching up to Up = 2800 kV PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN IEC 60230:2018-06 | IEC 60230:2018+AMD1:2021 CSV | PN-EN 61442:2005 | PN-EN IEC 61442:2025-08 | IEC 61442:2023 | IEC 60055-1:1997+AMD1:2005 CSV | IEC 60502-1:2021 | IEC 60502-2:2014 | IEC 60502-2:2014/AMD1:2024 | IEC 60502-4:2023 | IEC 60840:2020 | IEC 60840:2020/COR1:2021 | IEC 60840:2020/AMD1:2023 | IEC 62067:2022 | PN-HD 621 S1:2003 | PN-HD 632 S3:2017-03 | PN-HD 629-1-S3:2019-10 | PN-HD 629.2 S2:2006 | PN-HD 629.2 S2:2006/A1:2008","methodology_zh":"冲击电压下的介电强度：","parameters_zh":[{"name":"雷电冲击至 Up = 4500 kV"},{"name":"操作冲击至 Up = 2800 kV"}],"search_zh":"Un = (3,6 - 245) kV 的电缆与电缆附件 冲击电压下的介电强度： 雷电冲击至 Up = 4500 kV 操作冲击至 Up = 2800 kV PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN IEC 60230:2018-06 | IEC 60230:2018+AMD1:2021 CSV | PN-EN 61442:2005 | PN-EN IEC 61442:2025-08 | IEC 61442:2023 | IEC 60055-1:1997+AMD1:2005 CSV | IEC 60502-1:2021 | IEC 60502-2:2014 | IEC 60502-2:2014/AMD1:2024 | IEC 60502-4:2023 | IEC 60840:2020 | IEC 60840:2020/COR1:2021 | IEC 60840:2020/AMD1:2023 | IEC 62067:2022 | PN-HD 621 S1:2003 | PN-HD 632 S3:2017-03 | PN-HD 629-1-S3:2019-10 | PN-HD 629.2 S2:2006 | PN-HD 629.2 S2:2006/A1:2008","test_object_zh":"Un = (3,6 - 245) kV 的电缆与电缆附件"},{"_id":"6a5dc9adf1c10c8ce825ac58","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Kable i osprzęt kablowy o Un = (3,6 - 245) kV","test_object_en":"Cables and cable accessories with Un = (3,6 - 245) kV","methodology":"Wytrzymałość elektryczna przy napięciu przemiennym:","methodology_en":"Electric strength at alternating voltage:","parameters":[{"name":"50 Hz do Up = 1000 kV"},{"name":"Power frequency 50 Hz voltage"}],"parameters_en":[{"name":"50 Hz up to Up = 1000 kV"},{"name":"Power frequency 50 Hz voltage"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość elektryczna przy napięciu przemiennym:\nZakres:\n50 Hz do Up = 1000 kV\nPower frequency 50 Hz voltage","reference":"PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | IEC 60055-1:1997+AMD1:2005 CSV | IEC 60502-1:2021 | IEC 60502-2:2014 | IEC 60502-2:2014/AMD1:2024 | IEC 60502-4:2023 | IEC 60840:2020 | IEC 60840:2020/COR1:2021 | IEC 60840:2020/AMD1:2023 | IEC 62067:2022 | PN-HD 620 S3:2023-04 | PN-HD 629-1-S3:2019-10 | PN-HD 629.2:S2:2006 | PN-HD 629.2 S2:2006/A1:2008 | PN-EN 61442:2005 | PN-EN IEC 61442:2025-08 | PN-EN 50393:2015-03 | EN 50393:2015","norm_bases":["PN-EN 60060-1:2011","IEC 60060-1:2025","PN-EN 60060-2:2011","IEC 60060-2:2025","IEC 60055-1:1997+AMD1:2005 CSV","IEC 60502-1:2021","IEC 60502-2:2014","IEC 60502-2:2014/AMD1:2024","IEC 60502-4:2023","IEC 60840:2020","IEC 60840:2020/COR1:2021","IEC 60840:2020/AMD1:2023","IEC 62067:2022","PN-HD 620 S3:2023-04","PN-HD 629-1-S3:2019-10","PN-HD 629.2:S2:2006","PN-HD 629.2 S2:2006/A1:2008","PN-EN 61442:2005","PN-EN IEC 61442:2025-08","PN-EN 50393:2015-03","EN 50393:2015"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable i osprzęt kablowy o Un = (3,6 - 245) kV Wytrzymałość elektryczna przy napięciu przemiennym:\nZakres:\n50 Hz do Up = 1000 kV\nPower frequency 50 Hz voltage PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | IEC 60055-1:1997+AMD1:2005 CSV | IEC 60502-1:2021 | IEC 60502-2:2014 | IEC 60502-2:2014/AMD1:2024 | IEC 60502-4:2023 | IEC 60840:2020 | IEC 60840:2020/COR1:2021 | IEC 60840:2020/AMD1:2023 | IEC 62067:2022 | PN-HD 620 S3:2023-04 | PN-HD 629-1-S3:2019-10 | PN-HD 629.2:S2:2006 | PN-HD 629.2 S2:2006/A1:2008 | PN-EN 61442:2005 | PN-EN IEC 61442:2025-08 | PN-EN 50393:2015-03 | EN 50393:2015 Kable i osprzet kablowy o Un = (3,6 - 245) kV Wytrzymalosc elektryczna przy napieciu przemiennym:\nZakres:\n50 Hz do Up = 1000 kV\nPower frequency 50 Hz voltage PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | IEC 60055-1:1997+AMD1:2005 CSV | IEC 60502-1:2021 | IEC 60502-2:2014 | IEC 60502-2:2014/AMD1:2024 | IEC 60502-4:2023 | IEC 60840:2020 | IEC 60840:2020/COR1:2021 | IEC 60840:2020/AMD1:2023 | IEC 62067:2022 | PN-HD 620 S3:2023-04 | PN-HD 629-1-S3:2019-10 | PN-HD 629.2:S2:2006 | PN-HD 629.2 S2:2006/A1:2008 | PN-EN 61442:2005 | PN-EN IEC 61442:2025-08 | PN-EN 50393:2015-03 | EN 50393:2015","categories":["other"],"row_index":30,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables and cable accessories with Un = (3,6 - 245) kV Electric strength at alternating voltage: 50 Hz up to Up = 1000 kV Power frequency 50 Hz voltage PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | IEC 60055-1:1997+AMD1:2005 CSV | IEC 60502-1:2021 | IEC 60502-2:2014 | IEC 60502-2:2014/AMD1:2024 | IEC 60502-4:2023 | IEC 60840:2020 | IEC 60840:2020/COR1:2021 | IEC 60840:2020/AMD1:2023 | IEC 62067:2022 | PN-HD 620 S3:2023-04 | PN-HD 629-1-S3:2019-10 | PN-HD 629.2:S2:2006 | PN-HD 629.2 S2:2006/A1:2008 | PN-EN 61442:2005 | PN-EN IEC 61442:2025-08 | PN-EN 50393:2015-03 | EN 50393:2015","search_zh":"Un = (3,6 - 245) kV 的电缆与电缆附件 交流电压下的介电强度： PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | IEC 60055-1:1997+AMD1:2005 CSV | IEC 60502-1:2021 | IEC 60502-2:2014 | IEC 60502-2:2014/AMD1:2024 | IEC 60502-4:2023 | IEC 60840:2020 | IEC 60840:2020/COR1:2021 | IEC 60840:2020/AMD1:2023 | IEC 62067:2022 | PN-HD 620 S3:2023-04 | PN-HD 629-1-S3:2019-10 | PN-HD 629.2:S2:2006 | PN-HD 629.2 S2:2006/A1:2008 | PN-EN 61442:2005 | PN-EN IEC 61442:2025-08 | PN-EN 50393:2015-03 | EN 50393:2015","test_object_zh":"Un = (3,6 - 245) kV 的电缆与电缆附件","methodology_zh":"交流电压下的介电强度："},{"_id":"6a5dc9adf1c10c8ce825ac59","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Kable i osprzęt kablowy o Un = (3,6 - 245) kV","test_object_en":"Cables and cable accessories with Un = (3,6 - 245) kV","methodology":"Próba w mgle wodnej oraz solnej: do Up = 100kV","methodology_en":"Test in water and salt mist: up to Up = 100kV","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Próba w mgle wodnej oraz solnej: do Up = 100kV","reference":"PN-EN 61442:2005 | PN-EN IEC 61442:2025-08 | IEC 61442:2023 | PN-HD 629-1-S3:2019-10","norm_bases":["PN-EN 61442:2005","PN-EN IEC 61442:2025-08","IEC 61442:2023","PN-HD 629-1-S3:2019-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable i osprzęt kablowy o Un = (3,6 - 245) kV Próba w mgle wodnej oraz solnej: do Up = 100kV PN-EN 61442:2005 | PN-EN IEC 61442:2025-08 | IEC 61442:2023 | PN-HD 629-1-S3:2019-10 Kable i osprzet kablowy o Un = (3,6 - 245) kV Proba w mgle wodnej oraz solnej: do Up = 100kV PN-EN 61442:2005 | PN-EN IEC 61442:2025-08 | IEC 61442:2023 | PN-HD 629-1-S3:2019-10","categories":["other"],"row_index":31,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables and cable accessories with Un = (3,6 - 245) kV Test in water and salt mist: up to Up = 100kV PN-EN 61442:2005 | PN-EN IEC 61442:2025-08 | IEC 61442:2023 | PN-HD 629-1-S3:2019-10","search_zh":"Un = (3,6 - 245) kV 的电缆与电缆附件 PN-EN 61442:2005 | PN-EN IEC 61442:2025-08 | IEC 61442:2023 | PN-HD 629-1-S3:2019-10","test_object_zh":"Un = (3,6 - 245) kV 的电缆与电缆附件"},{"_id":"6a5dc9adf1c10c8ce825ac5a","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Kable i osprzęt kablowy o Un = (3,6 - 245) kV","test_object_en":"Cables and cable accessories with Un = (3,6 - 245) kV","methodology":"Graniczne przyrosty temperatury Próby nagrzewania cyklicznego","methodology_en":"Limiting temperature rises Cyclic heating tests","parameters":[{"name":"Zakres","range":"do 20 kA"}],"parameters_en":[{"name":"Range","range":"do 20 kA"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Graniczne przyrosty temperatury Próby nagrzewania cyklicznego\nZakres do 20 kA","reference":"PN-HD 620 S3:2023-04 | PN-HD 629-1-S3:2019-10 | PN-HD 629.2:S2:2006 | PN-HD 629.2 S2:2006/A1:2008 | PN-EN 61442:2005 | PN-EN IEC 61442:2025-08 | PN-EN 50393:2015-03 | EN 50393:2015 | PN-HD 632 S3:2017-03 | IEC 60502-2:2014 | IEC 60502-2:2014/AMD1:2024","norm_bases":["PN-HD 620 S3:2023-04","PN-HD 629-1-S3:2019-10","PN-HD 629.2:S2:2006","PN-HD 629.2 S2:2006/A1:2008","PN-EN 61442:2005","PN-EN IEC 61442:2025-08","PN-EN 50393:2015-03","EN 50393:2015","PN-HD 632 S3:2017-03","IEC 60502-2:2014","IEC 60502-2:2014/AMD1:2024"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable i osprzęt kablowy o Un = (3,6 - 245) kV Graniczne przyrosty temperatury Próby nagrzewania cyklicznego\nZakres do 20 kA PN-HD 620 S3:2023-04 | PN-HD 629-1-S3:2019-10 | PN-HD 629.2:S2:2006 | PN-HD 629.2 S2:2006/A1:2008 | PN-EN 61442:2005 | PN-EN IEC 61442:2025-08 | PN-EN 50393:2015-03 | EN 50393:2015 | PN-HD 632 S3:2017-03 | IEC 60502-2:2014 | IEC 60502-2:2014/AMD1:2024 Kable i osprzet kablowy o Un = (3,6 - 245) kV Graniczne przyrosty temperatury Proby nagrzewania cyklicznego\nZakres do 20 kA PN-HD 620 S3:2023-04 | PN-HD 629-1-S3:2019-10 | PN-HD 629.2:S2:2006 | PN-HD 629.2 S2:2006/A1:2008 | PN-EN 61442:2005 | PN-EN IEC 61442:2025-08 | PN-EN 50393:2015-03 | EN 50393:2015 | PN-HD 632 S3:2017-03 | IEC 60502-2:2014 | IEC 60502-2:2014/AMD1:2024","categories":["other"],"row_index":32,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables and cable accessories with Un = (3,6 - 245) kV Limiting temperature rises Cyclic heating tests Range PN-HD 620 S3:2023-04 | PN-HD 629-1-S3:2019-10 | PN-HD 629.2:S2:2006 | PN-HD 629.2 S2:2006/A1:2008 | PN-EN 61442:2005 | PN-EN IEC 61442:2025-08 | PN-EN 50393:2015-03 | EN 50393:2015 | PN-HD 632 S3:2017-03 | IEC 60502-2:2014 | IEC 60502-2:2014/AMD1:2024","parameters_zh":[{"name":"范围","range":"do 20 kA"}],"search_zh":"Un = (3,6 - 245) kV 的电缆与电缆附件 范围 PN-HD 620 S3:2023-04 | PN-HD 629-1-S3:2019-10 | PN-HD 629.2:S2:2006 | PN-HD 629.2 S2:2006/A1:2008 | PN-EN 61442:2005 | PN-EN IEC 61442:2025-08 | PN-EN 50393:2015-03 | EN 50393:2015 | PN-HD 632 S3:2017-03 | IEC 60502-2:2014 | IEC 60502-2:2014/AMD1:2024","test_object_zh":"Un = (3,6 - 245) kV 的电缆与电缆附件"},{"_id":"6a5dc9adf1c10c8ce825ac5b","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Kable i osprzęt kablowy o Un = (3,6 - 245) kV","test_object_en":"Cables and cable accessories with Un = (3,6 - 245) kV","methodology":"Rezystancja izolacji","methodology_en":"Insulation resistance","parameters":[{"name":"Zakres","range":"do 1 TΩ"},{"name":"Sprawdzenie rezystancji izolacji"}],"parameters_en":[{"name":"Range","range":"do 1 TΩ"},{"name":"Verification of insulation resistance"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Rezystancja izolacji\nZakres:\nZakres do 1 TΩ\nSprawdzenie rezystancji izolacji","reference":"PN-EN 50393:2015","norm_bases":["PN-EN 50393:2015"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable i osprzęt kablowy o Un = (3,6 - 245) kV Rezystancja izolacji\nZakres:\nZakres do 1 TΩ\nSprawdzenie rezystancji izolacji PN-EN 50393:2015 Kable i osprzet kablowy o Un = (3,6 - 245) kV Rezystancja izolacji\nZakres:\nZakres do 1 TΩ\nSprawdzenie rezystancji izolacji PN-EN 50393:2015","categories":["construction"],"row_index":33,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables and cable accessories with Un = (3,6 - 245) kV Insulation resistance Range Verification of insulation resistance PN-EN 50393:2015","parameters_zh":[{"name":"范围","range":"do 1 TΩ"},{"name":"Sprawdzenie rezystancji izolacji"}],"search_zh":"Un = (3,6 - 245) kV 的电缆与电缆附件 绝缘电阻 范围 PN-EN 50393:2015","methodology_zh":"绝缘电阻","test_object_zh":"Un = (3,6 - 245) kV 的电缆与电缆附件"},{"_id":"6a5dc9adf1c10c8ce825ac5c","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Kable i osprzęt kablowy o Un = (3,6 - 245) kV","test_object_en":"Cables and cable accessories with Un = (3,6 - 245) kV","methodology":"Pomiar intensywności wyładowań niezupełnych (ładunku pozornego) przy napięciu o wartości skutecznej do 150 kV","methodology_en":"Measurement of partial discharge intensity (apparent charge) at a voltage with an r.m.s. value up to 150 kV","parameters":[{"name":"Zakres","range":"od 2 pC"}],"parameters_en":[{"name":"Range","range":"od 2 pC"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pomiar intensywności wyładowań niezupełnych (ładunku pozornego) przy napięciu o wartości skutecznej do 150 kV\nZakres od 2 pC","reference":"PN-HD 620 S3:2023-04 | PN-HD 629-1-S3:2019-10 | PN-EN 61442:2005 | PN-EN 60270:2003 | PN-EN 60270:2003/A1:2016","norm_bases":["PN-HD 620 S3:2023-04","PN-HD 629-1-S3:2019-10","PN-EN 61442:2005","PN-EN 60270:2003","PN-EN 60270:2003/A1:2016"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable i osprzęt kablowy o Un = (3,6 - 245) kV Pomiar intensywności wyładowań niezupełnych (ładunku pozornego) przy napięciu o wartości skutecznej do 150 kV\nZakres od 2 pC PN-HD 620 S3:2023-04 | PN-HD 629-1-S3:2019-10 | PN-EN 61442:2005 | PN-EN 60270:2003 | PN-EN 60270:2003/A1:2016 Kable i osprzet kablowy o Un = (3,6 - 245) kV Pomiar intensywnosci wyladowan niezupelnych (ladunku pozornego) przy napieciu o wartosci skutecznej do 150 kV\nZakres od 2 pC PN-HD 620 S3:2023-04 | PN-HD 629-1-S3:2019-10 | PN-EN 61442:2005 | PN-EN 60270:2003 | PN-EN 60270:2003/A1:2016","categories":["other"],"row_index":34,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables and cable accessories with Un = (3,6 - 245) kV Measurement of partial discharge intensity (apparent charge) at a voltage with an r.m.s. value up to 150 kV Range PN-HD 620 S3:2023-04 | PN-HD 629-1-S3:2019-10 | PN-EN 61442:2005 | PN-EN 60270:2003 | PN-EN 60270:2003/A1:2016","parameters_zh":[{"name":"范围","range":"od 2 pC"}],"search_zh":"Un = (3,6 - 245) kV 的电缆与电缆附件 范围 PN-HD 620 S3:2023-04 | PN-HD 629-1-S3:2019-10 | PN-EN 61442:2005 | PN-EN 60270:2003 | PN-EN 60270:2003/A1:2016","test_object_zh":"Un = (3,6 - 245) kV 的电缆与电缆附件"},{"_id":"6a5dc9adf1c10c8ce825ac5d","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Osprzęt linii napowietrznych i stacji o Un = (110 - 400) kV","test_object_en":"Fittings for overhead lines and substations with Un = (110 - 400) kV","methodology":"Poziom zakłóceń radioelektrycznych (RIV) i poziom wyładowań niezupełnych (PD): maksymalne Up = 400 kV","methodology_en":"Radio interference voltage level (RIV) and partial discharge level (PD): maximum Up = 400 kV","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Poziom zakłóceń radioelektrycznych (RIV) i poziom wyładowań niezupełnych (PD): maksymalne Up = 400 kV","reference":"PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 CISPR 18-2:2010 | PN-EN 60270:2003 | PN-EN 60270:2003/A1:2016-04 | IEC 60270:2025 | PN-EN 61284:2002 | IEC 61284:1997 | IEC 61284:1997/COR1:1998","norm_bases":["PN-EN 60060-1:2011","IEC 60060-1:2025","PN-EN 60060-2:2011","IEC 60060-2:2025 CISPR 18-2:2010","PN-EN 60270:2003","PN-EN 60270:2003/A1:2016-04","IEC 60270:2025","PN-EN 61284:2002","IEC 61284:1997","IEC 61284:1997/COR1:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osprzęt linii napowietrznych i stacji o Un = (110 - 400) kV Poziom zakłóceń radioelektrycznych (RIV) i poziom wyładowań niezupełnych (PD): maksymalne Up = 400 kV PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 CISPR 18-2:2010 | PN-EN 60270:2003 | PN-EN 60270:2003/A1:2016-04 | IEC 60270:2025 | PN-EN 61284:2002 | IEC 61284:1997 | IEC 61284:1997/COR1:1998 Osprzet linii napowietrznych i stacji o Un = (110 - 400) kV Poziom zaklocen radioelektrycznych (RIV) i poziom wyladowan niezupelnych (PD): maksymalne Up = 400 kV PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 CISPR 18-2:2010 | PN-EN 60270:2003 | PN-EN 60270:2003/A1:2016-04 | IEC 60270:2025 | PN-EN 61284:2002 | IEC 61284:1997 | IEC 61284:1997/COR1:1998","categories":["other"],"row_index":35,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Fittings for overhead lines and substations with Un = (110 - 400) kV Radio interference voltage level (RIV) and partial discharge level (PD): maximum Up = 400 kV PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 CISPR 18-2:2010 | PN-EN 60270:2003 | PN-EN 60270:2003/A1:2016-04 | IEC 60270:2025 | PN-EN 61284:2002 | IEC 61284:1997 | IEC 61284:1997/COR1:1998","methodology_zh":"无线电干扰电压（RIV）与局部放电（PD）水平：最大 Up = 400 kV","search_zh":"无线电干扰电压（RIV）与局部放电（PD）水平：最大 Up = 400 kV PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 CISPR 18-2:2010 | PN-EN 60270:2003 | PN-EN 60270:2003/A1:2016-04 | IEC 60270:2025 | PN-EN 61284:2002 | IEC 61284:1997 | IEC 61284:1997/COR1:1998"},{"_id":"6a5dc9adf1c10c8ce825ac5e","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Sprzęt BHP o Un = (1 - 400) kV, Personal protective equipment","test_object_en":"Personal protective equipment with Un = (1 - 400) kV","methodology":"Wytrzymałość elektryczna przy napięciu przemiennym:","methodology_en":"Electric strength at alternating voltage:","parameters":[{"name":"50 Hz do Up = 1000 kV"},{"name":"Power frequency 50 Hz voltage withstand"}],"parameters_en":[{"name":"50 Hz up to Up = 1000 kV"},{"name":"Power frequency 50 Hz voltage withstand"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość elektryczna przy napięciu przemiennym:\nZakres:\n50 Hz do Up = 1000 kV\nPower frequency 50 Hz voltage withstand","reference":"PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 60832-1:2010 | IEC 60832-1:2010 | PN-EN 60832-2:2010 | IEC 60832-2:2010 | PN-EN 61243-3:2015-04 | PN-EN 61243-3:2015-04/AC1:2015-06 | IEC 61243-3:2014 | IEC 61243-3:2014/COR1:2015 | IEC 61243-3:2014/COR2:2015 | PN-EN IEC 61243-1:2022-01 | IEC 61243-1:2021 | PN-EN 61481-1:2015-04 | PN-EN 61481-1:2015-04/AC1:2018-12 | IEC 61481-1:2014 | IEC 61481-1:2014/COR1:2015 | PN-EN 61481-2:2015-04 | IEC 61481-2:2014 | PN-EN 60855-1:2017-04 | IEC 60855-1:2016 | PN-EN 61478:2005 | IEC 61478:2001 | IEC 61478:2001/AMD1:2003 | PN-EN IEC 60900:2018-10 | PN-EN IEC 60900:2018-10/AC:2020-09E | IEC 60900:2018 | IEC 60900:2018/COR1:2019 | IEC 60900:2018/COR2:2020 | PN-EN 60903:2006 | IEC 60903:2014 | PN-EN 61235:1999 | IEC 61235:1993 | IEC 61235:1993/COR1:1999 | IEC 61235:1993/COR2:2000 | PN-EN 61111:2009 | IEC 61111:2009 | PN-EN 3-7+A1:2008","norm_bases":["PN-EN 60060-1:2011","IEC 60060-1:2025","PN-EN 60060-2:2011","IEC 60060-2:2025","PN-EN 60832-1:2010","IEC 60832-1:2010","PN-EN 60832-2:2010","IEC 60832-2:2010","PN-EN 61243-3:2015-04","PN-EN 61243-3:2015-04/AC1:2015-06","IEC 61243-3:2014","IEC 61243-3:2014/COR1:2015","IEC 61243-3:2014/COR2:2015","PN-EN IEC 61243-1:2022-01","IEC 61243-1:2021","PN-EN 61481-1:2015-04","PN-EN 61481-1:2015-04/AC1:2018-12","IEC 61481-1:2014","IEC 61481-1:2014/COR1:2015","PN-EN 61481-2:2015-04","IEC 61481-2:2014","PN-EN 60855-1:2017-04","IEC 60855-1:2016","PN-EN 61478:2005","IEC 61478:2001","IEC 61478:2001/AMD1:2003","PN-EN IEC 60900:2018-10","PN-EN IEC 60900:2018-10/AC:2020-09E","IEC 60900:2018","IEC 60900:2018/COR1:2019","IEC 60900:2018/COR2:2020","PN-EN 60903:2006","IEC 60903:2014","PN-EN 61235:1999","IEC 61235:1993","IEC 61235:1993/COR1:1999","IEC 61235:1993/COR2:2000","PN-EN 61111:2009","IEC 61111:2009","PN-EN 3-7+A1:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Sprzęt BHP o Un = (1 - 400) kV, Personal protective equipment Wytrzymałość elektryczna przy napięciu przemiennym:\nZakres:\n50 Hz do Up = 1000 kV\nPower frequency 50 Hz voltage withstand PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 60832-1:2010 | IEC 60832-1:2010 | PN-EN 60832-2:2010 | IEC 60832-2:2010 | PN-EN 61243-3:2015-04 | PN-EN 61243-3:2015-04/AC1:2015-06 | IEC 61243-3:2014 | IEC 61243-3:2014/COR1:2015 | IEC 61243-3:2014/COR2:2015 | PN-EN IEC 61243-1:2022-01 | IEC 61243-1:2021 | PN-EN 61481-1:2015-04 | PN-EN 61481-1:2015-04/AC1:2018-12 | IEC 61481-1:2014 | IEC 61481-1:2014/COR1:2015 | PN-EN 61481-2:2015-04 | IEC 61481-2:2014 | PN-EN 60855-1:2017-04 | IEC 60855-1:2016 | PN-EN 61478:2005 | IEC 61478:2001 | IEC 61478:2001/AMD1:2003 | PN-EN IEC 60900:2018-10 | PN-EN IEC 60900:2018-10/AC:2020-09E | IEC 60900:2018 | IEC 60900:2018/COR1:2019 | IEC 60900:2018/COR2:2020 | PN-EN 60903:2006 | IEC 60903:2014 | PN-EN 61235:1999 | IEC 61235:1993 | IEC 61235:1993/COR1:1999 | IEC 61235:1993/COR2:2000 | PN-EN 61111:2009 | IEC 61111:2009 | PN-EN 3-7+A1:2008 Sprzet BHP o Un = (1 - 400) kV, Personal protective equipment Wytrzymalosc elektryczna przy napieciu przemiennym:\nZakres:\n50 Hz do Up = 1000 kV\nPower frequency 50 Hz voltage withstand PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 60832-1:2010 | IEC 60832-1:2010 | PN-EN 60832-2:2010 | IEC 60832-2:2010 | PN-EN 61243-3:2015-04 | PN-EN 61243-3:2015-04/AC1:2015-06 | IEC 61243-3:2014 | IEC 61243-3:2014/COR1:2015 | IEC 61243-3:2014/COR2:2015 | PN-EN IEC 61243-1:2022-01 | IEC 61243-1:2021 | PN-EN 61481-1:2015-04 | PN-EN 61481-1:2015-04/AC1:2018-12 | IEC 61481-1:2014 | IEC 61481-1:2014/COR1:2015 | PN-EN 61481-2:2015-04 | IEC 61481-2:2014 | PN-EN 60855-1:2017-04 | IEC 60855-1:2016 | PN-EN 61478:2005 | IEC 61478:2001 | IEC 61478:2001/AMD1:2003 | PN-EN IEC 60900:2018-10 | PN-EN IEC 60900:2018-10/AC:2020-09E | IEC 60900:2018 | IEC 60900:2018/COR1:2019 | IEC 60900:2018/COR2:2020 | PN-EN 60903:2006 | IEC 60903:2014 | PN-EN 61235:1999 | IEC 61235:1993 | IEC 61235:1993/COR1:1999 | IEC 61235:1993/COR2:2000 | PN-EN 61111:2009 | IEC 61111:2009 | PN-EN 3-7+A1:2008","categories":["other"],"row_index":36,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Personal protective equipment with Un = (1 - 400) kV Electric strength at alternating voltage: 50 Hz up to Up = 1000 kV Power frequency 50 Hz voltage withstand PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 60832-1:2010 | IEC 60832-1:2010 | PN-EN 60832-2:2010 | IEC 60832-2:2010 | PN-EN 61243-3:2015-04 | PN-EN 61243-3:2015-04/AC1:2015-06 | IEC 61243-3:2014 | IEC 61243-3:2014/COR1:2015 | IEC 61243-3:2014/COR2:2015 | PN-EN IEC 61243-1:2022-01 | IEC 61243-1:2021 | PN-EN 61481-1:2015-04 | PN-EN 61481-1:2015-04/AC1:2018-12 | IEC 61481-1:2014 | IEC 61481-1:2014/COR1:2015 | PN-EN 61481-2:2015-04 | IEC 61481-2:2014 | PN-EN 60855-1:2017-04 | IEC 60855-1:2016 | PN-EN 61478:2005 | IEC 61478:2001 | IEC 61478:2001/AMD1:2003 | PN-EN IEC 60900:2018-10 | PN-EN IEC 60900:2018-10/AC:2020-09E | IEC 60900:2018 | IEC 60900:2018/COR1:2019 | IEC 60900:2018/COR2:2020 | PN-EN 60903:2006 | IEC 60903:2014 | PN-EN 61235:1999 | IEC 61235:1993 | IEC 61235:1993/COR1:1999 | IEC 61235:1993/COR2:2000 | PN-EN 61111:2009 | IEC 61111:2009 | PN-EN 3-7+A1:2008","methodology_zh":"交流电压下的介电强度：","search_zh":"交流电压下的介电强度： PN-EN 60060-1:2011 | IEC 60060-1:2025 | PN-EN 60060-2:2011 | IEC 60060-2:2025 | PN-EN 60832-1:2010 | IEC 60832-1:2010 | PN-EN 60832-2:2010 | IEC 60832-2:2010 | PN-EN 61243-3:2015-04 | PN-EN 61243-3:2015-04/AC1:2015-06 | IEC 61243-3:2014 | IEC 61243-3:2014/COR1:2015 | IEC 61243-3:2014/COR2:2015 | PN-EN IEC 61243-1:2022-01 | IEC 61243-1:2021 | PN-EN 61481-1:2015-04 | PN-EN 61481-1:2015-04/AC1:2018-12 | IEC 61481-1:2014 | IEC 61481-1:2014/COR1:2015 | PN-EN 61481-2:2015-04 | IEC 61481-2:2014 | PN-EN 60855-1:2017-04 | IEC 60855-1:2016 | PN-EN 61478:2005 | IEC 61478:2001 | IEC 61478:2001/AMD1:2003 | PN-EN IEC 60900:2018-10 | PN-EN IEC 60900:2018-10/AC:2020-09E | IEC 60900:2018 | IEC 60900:2018/COR1:2019 | IEC 60900:2018/COR2:2020 | PN-EN 60903:2006 | IEC 60903:2014 | PN-EN 61235:1999 | IEC 61235:1993 | IEC 61235:1993/COR1:1999 | IEC 61235:1993/COR2:2000 | PN-EN 61111:2009 | IEC 61111:2009 | PN-EN 3-7+A1:2008"},{"_id":"6a5dc9adf1c10c8ce825ac5f","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Szynoprzewody i mosty szynowe WN, High-voltage busbars","test_object_en":"High-voltage busbars and busbar bridges","methodology":"Wytrzymałość elektryczna","methodology_en":"Electric strength","parameters":[{"name":"Zakres","range":"do 150 kV"},{"name":"Próby napięciem przemiennym Power frequency 50 Hz voltage"}],"parameters_en":[{"name":"Range","range":"do 150 kV"},{"name":"Alternating voltage tests Power frequency 50 Hz voltage"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość elektryczna\nZakres:\nZakres do 150 kV\nPróby napięciem przemiennym Power frequency 50 Hz voltage","reference":"PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 CSV ANSI/IEEE C37.23-2015","norm_bases":["PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-1:2017+AMD1:2021 CSV ANSI/IEEE C37.23-2015"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Szynoprzewody i mosty szynowe WN, High-voltage busbars Wytrzymałość elektryczna\nZakres:\nZakres do 150 kV\nPróby napięciem przemiennym Power frequency 50 Hz voltage PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 CSV ANSI/IEEE C37.23-2015 Szynoprzewody i mosty szynowe WN, High-voltage busbars Wytrzymalosc elektryczna\nZakres:\nZakres do 150 kV\nProby napieciem przemiennym Power frequency 50 Hz voltage PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 CSV ANSI/IEEE C37.23-2015","categories":["other"],"row_index":37,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"High-voltage busbars and busbar bridges Electric strength Range Alternating voltage tests Power frequency 50 Hz voltage PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 CSV ANSI/IEEE C37.23-2015","parameters_zh":[{"name":"范围","range":"do 150 kV"},{"name":"Próby napięciem przemiennym Power frequency 50 Hz voltage"}],"search_zh":"介电强度 范围 PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017+AMD1:2021 CSV ANSI/IEEE C37.23-2015","methodology_zh":"介电强度"},{"_id":"6a5dc9adf1c10c8ce825ac60","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Rozdzielnice i sterownice niskonapięciowe","test_object_en":"Low-voltage switchgear and controlgear assemblies","methodology":"Wytrzymałość elektryczna przy napięciu udarowym piorunowym, Zakres od: Up = 4,8 kV, Lightning impulse voltage","methodology_en":"Dielectric strength at lightning impulse voltage, Range from: Up = 4,8 kV, Lightning impulse voltage","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość elektryczna przy napięciu udarowym piorunowym, Zakres od: Up = 4,8 kV, Lightning impulse voltage","reference":"PN-EN IEC 61439-1:2021-10 | PN-EN IEC 61439-1:2021-10/AC:2022-03E | IEC 61439-1:2020 | IEC 61439-1:2020/COR1:2021 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | PN-EN 61439-4:2013-06/Ap1:2014-12E | IEC 61439-4:2023 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023","norm_bases":["PN-EN IEC 61439-1:2021-10","PN-EN IEC 61439-1:2021-10/AC:2022-03E","IEC 61439-1:2020","IEC 61439-1:2020/COR1:2021","PN-EN IEC 61439-2:2021-10","IEC 61439-2:2020","PN-EN IEC 61439-3:2025-09","IEC 61439-3:2024","PN-EN 61439-4:2013-06","PN-EN 61439-4:2013-06/Ap1:2014-12E","IEC 61439-4:2023","PN-EN IEC 61439-5:2024-04","IEC 61439-5:2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rozdzielnice i sterownice niskonapięciowe Wytrzymałość elektryczna przy napięciu udarowym piorunowym, Zakres od: Up = 4,8 kV, Lightning impulse voltage PN-EN IEC 61439-1:2021-10 | PN-EN IEC 61439-1:2021-10/AC:2022-03E | IEC 61439-1:2020 | IEC 61439-1:2020/COR1:2021 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | PN-EN 61439-4:2013-06/Ap1:2014-12E | IEC 61439-4:2023 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023 Rozdzielnice i sterownice niskonapieciowe Wytrzymalosc elektryczna przy napieciu udarowym piorunowym, Zakres od: Up = 4,8 kV, Lightning impulse voltage PN-EN IEC 61439-1:2021-10 | PN-EN IEC 61439-1:2021-10/AC:2022-03E | IEC 61439-1:2020 | IEC 61439-1:2020/COR1:2021 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | PN-EN 61439-4:2013-06/Ap1:2014-12E | IEC 61439-4:2023 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023","categories":["other"],"row_index":38,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Low-voltage switchgear and controlgear assemblies Dielectric strength at lightning impulse voltage, Range from: Up = 4,8 kV, Lightning impulse voltage PN-EN IEC 61439-1:2021-10 | PN-EN IEC 61439-1:2021-10/AC:2022-03E | IEC 61439-1:2020 | IEC 61439-1:2020/COR1:2021 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | PN-EN 61439-4:2013-06/Ap1:2014-12E | IEC 61439-4:2023 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023","search_zh":"低压成套开关设备与控制设备 PN-EN IEC 61439-1:2021-10 | PN-EN IEC 61439-1:2021-10/AC:2022-03E | IEC 61439-1:2020 | IEC 61439-1:2020/COR1:2021 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | PN-EN 61439-4:2013-06/Ap1:2014-12E | IEC 61439-4:2023 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023","test_object_zh":"低压成套开关设备与控制设备"},{"_id":"6a5dc9adf1c10c8ce825ac61","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Rozdzielnice i sterownice niskonapięciowe","test_object_en":"Low-voltage switchgear and controlgear assemblies","methodology":"Wytrzymałość elektryczna","methodology_en":"Electric strength","parameters":[{"name":"Zakres","range":"do 150 kV"},{"name":"Próby napięciem przemiennym"}],"parameters_en":[{"name":"Range","range":"do 150 kV"},{"name":"Alternating voltage tests"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość elektryczna\nZakres:\nZakres do 150 kV\nPróby napięciem przemiennym","reference":"PN-EN IEC 61439-1:2021-10 | PN-EN IEC 61439-1:2021-10/AC:2022-03E | IEC 61439-1:2020 | IEC 61439-1:2020/COR1:2021 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | PN-EN 61439-4:2013-06/Ap1:2014-12E | IEC 61439-4:2023 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023","norm_bases":["PN-EN IEC 61439-1:2021-10","PN-EN IEC 61439-1:2021-10/AC:2022-03E","IEC 61439-1:2020","IEC 61439-1:2020/COR1:2021","PN-EN IEC 61439-2:2021-10","IEC 61439-2:2020","PN-EN IEC 61439-3:2025-09","IEC 61439-3:2024","PN-EN 61439-4:2013-06","PN-EN 61439-4:2013-06/Ap1:2014-12E","IEC 61439-4:2023","PN-EN IEC 61439-5:2024-04","IEC 61439-5:2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rozdzielnice i sterownice niskonapięciowe Wytrzymałość elektryczna\nZakres:\nZakres do 150 kV\nPróby napięciem przemiennym PN-EN IEC 61439-1:2021-10 | PN-EN IEC 61439-1:2021-10/AC:2022-03E | IEC 61439-1:2020 | IEC 61439-1:2020/COR1:2021 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | PN-EN 61439-4:2013-06/Ap1:2014-12E | IEC 61439-4:2023 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023 Rozdzielnice i sterownice niskonapieciowe Wytrzymalosc elektryczna\nZakres:\nZakres do 150 kV\nProby napieciem przemiennym PN-EN IEC 61439-1:2021-10 | PN-EN IEC 61439-1:2021-10/AC:2022-03E | IEC 61439-1:2020 | IEC 61439-1:2020/COR1:2021 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | PN-EN 61439-4:2013-06/Ap1:2014-12E | IEC 61439-4:2023 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023","categories":["other"],"row_index":39,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Low-voltage switchgear and controlgear assemblies Electric strength Range Alternating voltage tests PN-EN IEC 61439-1:2021-10 | PN-EN IEC 61439-1:2021-10/AC:2022-03E | IEC 61439-1:2020 | IEC 61439-1:2020/COR1:2021 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | PN-EN 61439-4:2013-06/Ap1:2014-12E | IEC 61439-4:2023 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023","parameters_zh":[{"name":"范围","range":"do 150 kV"},{"name":"Próby napięciem przemiennym"}],"search_zh":"低压成套开关设备与控制设备 介电强度 范围 PN-EN IEC 61439-1:2021-10 | PN-EN IEC 61439-1:2021-10/AC:2022-03E | IEC 61439-1:2020 | IEC 61439-1:2020/COR1:2021 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | PN-EN 61439-4:2013-06/Ap1:2014-12E | IEC 61439-4:2023 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023","test_object_zh":"低压成套开关设备与控制设备","methodology_zh":"介电强度"},{"_id":"6a5dc9adf1c10c8ce825ac62","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Wyłączniki niskiego napięcia, Low-voltage circuit breakers","test_object_en":"Low-voltage circuit breakers","methodology":"Wytrzymałość elektryczna przy napięciu udarowym piorunowym, Zakres od: Up = 4,8 kV, Lightning impulse voltage","methodology_en":"Dielectric strength at lightning impulse voltage, Range from: Up = 4,8 kV, Lightning impulse voltage","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość elektryczna przy napięciu udarowym piorunowym, Zakres od: Up = 4,8 kV, Lightning impulse voltage","reference":"PN-EN IEC 60947-1:2021-07 | PN-EN IEC 60947-1:2021-07/Ap1:2022-12E | PN-EN IEC 60947-1:2021-07/AC:2023-03E | IEC 60947-1:2020 | IEC 60947-1:2020/COR1:2022 | PN-EN 60947-2:2018-01 | PN-EN 60947-2:2018-01/A1:2020-06 | IEC 60947-2:2024","norm_bases":["PN-EN IEC 60947-1:2021-07","PN-EN IEC 60947-1:2021-07/Ap1:2022-12E","PN-EN IEC 60947-1:2021-07/AC:2023-03E","IEC 60947-1:2020","IEC 60947-1:2020/COR1:2022","PN-EN 60947-2:2018-01","PN-EN 60947-2:2018-01/A1:2020-06","IEC 60947-2:2024"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyłączniki niskiego napięcia, Low-voltage circuit breakers Wytrzymałość elektryczna przy napięciu udarowym piorunowym, Zakres od: Up = 4,8 kV, Lightning impulse voltage PN-EN IEC 60947-1:2021-07 | PN-EN IEC 60947-1:2021-07/Ap1:2022-12E | PN-EN IEC 60947-1:2021-07/AC:2023-03E | IEC 60947-1:2020 | IEC 60947-1:2020/COR1:2022 | PN-EN 60947-2:2018-01 | PN-EN 60947-2:2018-01/A1:2020-06 | IEC 60947-2:2024 Wylaczniki niskiego napiecia, Low-voltage circuit breakers Wytrzymalosc elektryczna przy napieciu udarowym piorunowym, Zakres od: Up = 4,8 kV, Lightning impulse voltage PN-EN IEC 60947-1:2021-07 | PN-EN IEC 60947-1:2021-07/Ap1:2022-12E | PN-EN IEC 60947-1:2021-07/AC:2023-03E | IEC 60947-1:2020 | IEC 60947-1:2020/COR1:2022 | PN-EN 60947-2:2018-01 | PN-EN 60947-2:2018-01/A1:2020-06 | IEC 60947-2:2024","categories":["other"],"row_index":40,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Low-voltage circuit breakers Dielectric strength at lightning impulse voltage, Range from: Up = 4,8 kV, Lightning impulse voltage PN-EN IEC 60947-1:2021-07 | PN-EN IEC 60947-1:2021-07/Ap1:2022-12E | PN-EN IEC 60947-1:2021-07/AC:2023-03E | IEC 60947-1:2020 | IEC 60947-1:2020/COR1:2022 | PN-EN 60947-2:2018-01 | PN-EN 60947-2:2018-01/A1:2020-06 | IEC 60947-2:2024","search_zh":"低压断路器 Low-voltage circuit breakers PN-EN IEC 60947-1:2021-07 | PN-EN IEC 60947-1:2021-07/Ap1:2022-12E | PN-EN IEC 60947-1:2021-07/AC:2023-03E | IEC 60947-1:2020 | IEC 60947-1:2020/COR1:2022 | PN-EN 60947-2:2018-01 | PN-EN 60947-2:2018-01/A1:2020-06 | IEC 60947-2:2024","test_object_zh":"低压断路器 Low-voltage circuit breakers"},{"_id":"6a5dc9adf1c10c8ce825ac63","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Wyłączniki niskiego napięcia, Low-voltage circuit breakers","test_object_en":"Low-voltage circuit breakers","methodology":"Próby napięciem przemiennym 50 Hz do Up =150 KV","methodology_en":"Alternating voltage tests 50 Hz up to Up =150 KV","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Próby napięciem przemiennym 50 Hz do Up =150 KV","reference":"PN-EN IEC 60947-1:2021-07 | PN-EN IEC 60947-1:2021-07/Ap1:2022-12E | PN-EN IEC 60947-1:2021-07/AC:2023-03E | IEC 60947-1:2020 | IEC 60947-1:2020/COR1:2022 | PN-EN 60947-2:2018-01 | PN-EN 60947-2:2018-01/A1:2020-06 | IEC 60947-2:2024","norm_bases":["PN-EN IEC 60947-1:2021-07","PN-EN IEC 60947-1:2021-07/Ap1:2022-12E","PN-EN IEC 60947-1:2021-07/AC:2023-03E","IEC 60947-1:2020","IEC 60947-1:2020/COR1:2022","PN-EN 60947-2:2018-01","PN-EN 60947-2:2018-01/A1:2020-06","IEC 60947-2:2024"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyłączniki niskiego napięcia, Low-voltage circuit breakers Próby napięciem przemiennym 50 Hz do Up =150 KV PN-EN IEC 60947-1:2021-07 | PN-EN IEC 60947-1:2021-07/Ap1:2022-12E | PN-EN IEC 60947-1:2021-07/AC:2023-03E | IEC 60947-1:2020 | IEC 60947-1:2020/COR1:2022 | PN-EN 60947-2:2018-01 | PN-EN 60947-2:2018-01/A1:2020-06 | IEC 60947-2:2024 Wylaczniki niskiego napiecia, Low-voltage circuit breakers Proby napieciem przemiennym 50 Hz do Up =150 KV PN-EN IEC 60947-1:2021-07 | PN-EN IEC 60947-1:2021-07/Ap1:2022-12E | PN-EN IEC 60947-1:2021-07/AC:2023-03E | IEC 60947-1:2020 | IEC 60947-1:2020/COR1:2022 | PN-EN 60947-2:2018-01 | PN-EN 60947-2:2018-01/A1:2020-06 | IEC 60947-2:2024","categories":["other"],"row_index":41,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Low-voltage circuit breakers Alternating voltage tests 50 Hz up to Up =150 KV PN-EN IEC 60947-1:2021-07 | PN-EN IEC 60947-1:2021-07/Ap1:2022-12E | PN-EN IEC 60947-1:2021-07/AC:2023-03E | IEC 60947-1:2020 | IEC 60947-1:2020/COR1:2022 | PN-EN 60947-2:2018-01 | PN-EN 60947-2:2018-01/A1:2020-06 | IEC 60947-2:2024","search_zh":"低压断路器 Low-voltage circuit breakers PN-EN IEC 60947-1:2021-07 | PN-EN IEC 60947-1:2021-07/Ap1:2022-12E | PN-EN IEC 60947-1:2021-07/AC:2023-03E | IEC 60947-1:2020 | IEC 60947-1:2020/COR1:2022 | PN-EN 60947-2:2018-01 | PN-EN 60947-2:2018-01/A1:2020-06 | IEC 60947-2:2024","test_object_zh":"低压断路器 Low-voltage circuit breakers"},{"_id":"6a5dc9adf1c10c8ce825ac64","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Rozłączniki, odłączniki, rozłączniki izolacyjne i zestawy łączników z bezpiecznikami topikowymi, niskiego napięcia, Low-voltage switches, disconnectors, switch-","test_object_en":"Low-voltage switches, disconnectors, switch-disconnectors and fuse-combination units","methodology":"Wytrzymałość elektryczna przy napięciu udarowym piorunowym, Zakres od: Up = 4,8 kV, Lightning impulse voltage","methodology_en":"Dielectric strength at lightning impulse voltage, Range from: Up = 4,8 kV, Lightning impulse voltage","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość elektryczna przy napięciu udarowym piorunowym, Zakres od: Up = 4,8 kV, Lightning impulse voltage","reference":"PN-EN IEC 60947-1:2021-07 | PN-EN IEC 60947-1:2021-07/Ap1:2022-12E | PN-EN IEC 60947-1:2021-07/AC:2023-03E | IEC 60947-1:2020 | IEC 60947-1:2020/COR1:2022 | PN-EN IEC 60947-3:2021-07 | PN-EN IEC 60947-3:2021-07/AC:2022-01E | IEC 60947-3:2020 | IEC 60947-3:2020/COR1:2021 | IEC 60947-3:2020/AMD1:2025","norm_bases":["PN-EN IEC 60947-1:2021-07","PN-EN IEC 60947-1:2021-07/Ap1:2022-12E","PN-EN IEC 60947-1:2021-07/AC:2023-03E","IEC 60947-1:2020","IEC 60947-1:2020/COR1:2022","PN-EN IEC 60947-3:2021-07","PN-EN IEC 60947-3:2021-07/AC:2022-01E","IEC 60947-3:2020","IEC 60947-3:2020/COR1:2021","IEC 60947-3:2020/AMD1:2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rozłączniki, odłączniki, rozłączniki izolacyjne i zestawy łączników z bezpiecznikami topikowymi, niskiego napięcia, Low-voltage switches, disconnectors, switch- Wytrzymałość elektryczna przy napięciu udarowym piorunowym, Zakres od: Up = 4,8 kV, Lightning impulse voltage PN-EN IEC 60947-1:2021-07 | PN-EN IEC 60947-1:2021-07/Ap1:2022-12E | PN-EN IEC 60947-1:2021-07/AC:2023-03E | IEC 60947-1:2020 | IEC 60947-1:2020/COR1:2022 | PN-EN IEC 60947-3:2021-07 | PN-EN IEC 60947-3:2021-07/AC:2022-01E | IEC 60947-3:2020 | IEC 60947-3:2020/COR1:2021 | IEC 60947-3:2020/AMD1:2025 Rozlaczniki, odlaczniki, rozlaczniki izolacyjne i zestawy lacznikow z bezpiecznikami topikowymi, niskiego napiecia, Low-voltage switches, disconnectors, switch- Wytrzymalosc elektryczna przy napieciu udarowym piorunowym, Zakres od: Up = 4,8 kV, Lightning impulse voltage PN-EN IEC 60947-1:2021-07 | PN-EN IEC 60947-1:2021-07/Ap1:2022-12E | PN-EN IEC 60947-1:2021-07/AC:2023-03E | IEC 60947-1:2020 | IEC 60947-1:2020/COR1:2022 | PN-EN IEC 60947-3:2021-07 | PN-EN IEC 60947-3:2021-07/AC:2022-01E | IEC 60947-3:2020 | IEC 60947-3:2020/COR1:2021 | IEC 60947-3:2020/AMD1:2025","categories":["construction"],"row_index":42,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Low-voltage switches, disconnectors, switch-disconnectors and fuse-combination units Dielectric strength at lightning impulse voltage, Range from: Up = 4,8 kV, Lightning impulse voltage PN-EN IEC 60947-1:2021-07 | PN-EN IEC 60947-1:2021-07/Ap1:2022-12E | PN-EN IEC 60947-1:2021-07/AC:2023-03E | IEC 60947-1:2020 | IEC 60947-1:2020/COR1:2022 | PN-EN IEC 60947-3:2021-07 | PN-EN IEC 60947-3:2021-07/AC:2022-01E | IEC 60947-3:2020 | IEC 60947-3:2020/COR1:2021 | IEC 60947-3:2020/AMD1:2025","search_zh":"低压负荷开关、隔离开关、隔离用开关及开关熔断器组合电器 Low-voltage switches, disconnectors, switch- PN-EN IEC 60947-1:2021-07 | PN-EN IEC 60947-1:2021-07/Ap1:2022-12E | PN-EN IEC 60947-1:2021-07/AC:2023-03E | IEC 60947-1:2020 | IEC 60947-1:2020/COR1:2022 | PN-EN IEC 60947-3:2021-07 | PN-EN IEC 60947-3:2021-07/AC:2022-01E | IEC 60947-3:2020 | IEC 60947-3:2020/COR1:2021 | IEC 60947-3:2020/AMD1:2025","test_object_zh":"低压负荷开关、隔离开关、隔离用开关及开关熔断器组合电器 Low-voltage switches, disconnectors, switch-"},{"_id":"6a5dc9adf1c10c8ce825ac65","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Rozłączniki, odłączniki, rozłączniki izolacyjne i zestawy łączników z bezpiecznikami topikowymi, niskiego napięcia, Low-voltage switches, disconnectors, switch-","test_object_en":"Low-voltage switches, disconnectors, switch-disconnectors and fuse-combination units","methodology":"Próby napięciem przemiennym 50 Hz do Up =150, KV","methodology_en":"Alternating voltage tests 50 Hz up to Up =150, KV","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Próby napięciem przemiennym 50 Hz do Up =150, KV","reference":"PN-EN IEC 60947-1:2021-07 | PN-EN IEC 60947-1:2021-07/Ap1:2022-12E | PN-EN IEC 60947-1:2021-07/AC:2023-03E | IEC 60947-1:2020 | IEC 60947-1:2020/COR1:2022 | PN-EN IEC 60947-3:2021-07 | PN-EN IEC 60947-3:2021-07/AC:2022-01E | IEC 60947-3:2020 | IEC 60947-3:2020/COR1:2021 | IEC 60947-3:2020/AMD1:2025","norm_bases":["PN-EN IEC 60947-1:2021-07","PN-EN IEC 60947-1:2021-07/Ap1:2022-12E","PN-EN IEC 60947-1:2021-07/AC:2023-03E","IEC 60947-1:2020","IEC 60947-1:2020/COR1:2022","PN-EN IEC 60947-3:2021-07","PN-EN IEC 60947-3:2021-07/AC:2022-01E","IEC 60947-3:2020","IEC 60947-3:2020/COR1:2021","IEC 60947-3:2020/AMD1:2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rozłączniki, odłączniki, rozłączniki izolacyjne i zestawy łączników z bezpiecznikami topikowymi, niskiego napięcia, Low-voltage switches, disconnectors, switch- Próby napięciem przemiennym 50 Hz do Up =150, KV PN-EN IEC 60947-1:2021-07 | PN-EN IEC 60947-1:2021-07/Ap1:2022-12E | PN-EN IEC 60947-1:2021-07/AC:2023-03E | IEC 60947-1:2020 | IEC 60947-1:2020/COR1:2022 | PN-EN IEC 60947-3:2021-07 | PN-EN IEC 60947-3:2021-07/AC:2022-01E | IEC 60947-3:2020 | IEC 60947-3:2020/COR1:2021 | IEC 60947-3:2020/AMD1:2025 Rozlaczniki, odlaczniki, rozlaczniki izolacyjne i zestawy lacznikow z bezpiecznikami topikowymi, niskiego napiecia, Low-voltage switches, disconnectors, switch- Proby napieciem przemiennym 50 Hz do Up =150, KV PN-EN IEC 60947-1:2021-07 | PN-EN IEC 60947-1:2021-07/Ap1:2022-12E | PN-EN IEC 60947-1:2021-07/AC:2023-03E | IEC 60947-1:2020 | IEC 60947-1:2020/COR1:2022 | PN-EN IEC 60947-3:2021-07 | PN-EN IEC 60947-3:2021-07/AC:2022-01E | IEC 60947-3:2020 | IEC 60947-3:2020/COR1:2021 | IEC 60947-3:2020/AMD1:2025","categories":["construction"],"row_index":43,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Low-voltage switches, disconnectors, switch-disconnectors and fuse-combination units Alternating voltage tests 50 Hz up to Up =150, KV PN-EN IEC 60947-1:2021-07 | PN-EN IEC 60947-1:2021-07/Ap1:2022-12E | PN-EN IEC 60947-1:2021-07/AC:2023-03E | IEC 60947-1:2020 | IEC 60947-1:2020/COR1:2022 | PN-EN IEC 60947-3:2021-07 | PN-EN IEC 60947-3:2021-07/AC:2022-01E | IEC 60947-3:2020 | IEC 60947-3:2020/COR1:2021 | IEC 60947-3:2020/AMD1:2025","search_zh":"低压负荷开关、隔离开关、隔离用开关及开关熔断器组合电器 Low-voltage switches, disconnectors, switch- PN-EN IEC 60947-1:2021-07 | PN-EN IEC 60947-1:2021-07/Ap1:2022-12E | PN-EN IEC 60947-1:2021-07/AC:2023-03E | IEC 60947-1:2020 | IEC 60947-1:2020/COR1:2022 | PN-EN IEC 60947-3:2021-07 | PN-EN IEC 60947-3:2021-07/AC:2022-01E | IEC 60947-3:2020 | IEC 60947-3:2020/COR1:2021 | IEC 60947-3:2020/AMD1:2025","test_object_zh":"低压负荷开关、隔离开关、隔离用开关及开关熔断器组合电器 Low-voltage switches, disconnectors, switch-"},{"_id":"6a5dc9adf1c10c8ce825ac66","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Rozdzielnice prądu przemiennego w osłonach metalowych na napięcia znamionowe do 52 kV AC metal-enclosed","test_object_en":"AC metal-enclosed switchgear and controlgear for rated voltages up to 52 kV","methodology":"Wytrzymałość zwarciowa","methodology_en":"Short-circuit withstand strength","parameters":[{"name":"Zakres","range":"do 150 kA rms / 400 kA peak"}],"parameters_en":[{"name":"Range","range":"do 150 kA rms / 400 kA peak"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość zwarciowa\nZakres do 150 kA rms / 400 kA peak","reference":"PN-EN IEC 62271-200:2022-02/A1:2025-04 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | IEC 62271-200:2021 | IEC 62271-200:2021/AMD1:2024 | PN-EN IEC 62271-200:2022-02","norm_bases":["PN-EN IEC 62271-200:2022-02/A1:2025-04","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-1:2017","IEC 62271-1:2017/AMD1:2021","IEC 62271-200:2021","IEC 62271-200:2021/AMD1:2024","PN-EN IEC 62271-200:2022-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rozdzielnice prądu przemiennego w osłonach metalowych na napięcia znamionowe do 52 kV AC metal-enclosed Wytrzymałość zwarciowa\nZakres do 150 kA rms / 400 kA peak PN-EN IEC 62271-200:2022-02/A1:2025-04 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | IEC 62271-200:2021 | IEC 62271-200:2021/AMD1:2024 | PN-EN IEC 62271-200:2022-02 Rozdzielnice pradu przemiennego w oslonach metalowych na napiecia znamionowe do 52 kV AC metal-enclosed Wytrzymalosc zwarciowa\nZakres do 150 kA rms / 400 kA peak PN-EN IEC 62271-200:2022-02/A1:2025-04 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | IEC 62271-200:2021 | IEC 62271-200:2021/AMD1:2024 | PN-EN IEC 62271-200:2022-02","categories":["materials"],"row_index":44,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"AC metal-enclosed switchgear and controlgear for rated voltages up to 52 kV Short-circuit withstand strength Range PN-EN IEC 62271-200:2022-02/A1:2025-04 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | IEC 62271-200:2021 | IEC 62271-200:2021/AMD1:2024 | PN-EN IEC 62271-200:2022-02","parameters_zh":[{"name":"范围","range":"do 150 kA rms / 400 kA peak"}],"search_zh":"额定电压至 52 kV 的金属封闭交流成套开关设备 AC metal-enclosed 短路耐受强度 范围 PN-EN IEC 62271-200:2022-02/A1:2025-04 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | IEC 62271-200:2021 | IEC 62271-200:2021/AMD1:2024 | PN-EN IEC 62271-200:2022-02","methodology_zh":"短路耐受强度","test_object_zh":"额定电压至 52 kV 的金属封闭交流成套开关设备 AC metal-enclosed"},{"_id":"6a5dc9adf1c10c8ce825ac67","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Rozdzielnice prądu przemiennego w osłonach metalowych na napięcia znamionowe do 52 kV AC metal-enclosed","test_object_en":"AC metal-enclosed switchgear and controlgear for rated voltages up to 52 kV","methodology":"Zdolność łączenia","methodology_en":"Switching capability","parameters":[{"name":"Zakres","range":"do 36 kV"}],"parameters_en":[{"name":"Range","range":"do 36 kV"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Zdolność łączenia\nZakres do 36 kV","reference":"PN-EN IEC 62271-200:2022-02/A1:2025-04 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | IEC 62271-200:2021 | IEC 62271-200:2021/AMD1:2024 | PN-EN IEC 62271-200:2022-02","norm_bases":["PN-EN IEC 62271-200:2022-02/A1:2025-04","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-1:2017","IEC 62271-1:2017/AMD1:2021","IEC 62271-200:2021","IEC 62271-200:2021/AMD1:2024","PN-EN IEC 62271-200:2022-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rozdzielnice prądu przemiennego w osłonach metalowych na napięcia znamionowe do 52 kV AC metal-enclosed Zdolność łączenia\nZakres do 36 kV PN-EN IEC 62271-200:2022-02/A1:2025-04 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | IEC 62271-200:2021 | IEC 62271-200:2021/AMD1:2024 | PN-EN IEC 62271-200:2022-02 Rozdzielnice pradu przemiennego w oslonach metalowych na napiecia znamionowe do 52 kV AC metal-enclosed Zdolnosc laczenia\nZakres do 36 kV PN-EN IEC 62271-200:2022-02/A1:2025-04 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | IEC 62271-200:2021 | IEC 62271-200:2021/AMD1:2024 | PN-EN IEC 62271-200:2022-02","categories":["materials"],"row_index":45,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"AC metal-enclosed switchgear and controlgear for rated voltages up to 52 kV Switching capability Range PN-EN IEC 62271-200:2022-02/A1:2025-04 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | IEC 62271-200:2021 | IEC 62271-200:2021/AMD1:2024 | PN-EN IEC 62271-200:2022-02","parameters_zh":[{"name":"范围","range":"do 36 kV"}],"search_zh":"额定电压至 52 kV 的金属封闭交流成套开关设备 AC metal-enclosed 接通与分断能力 范围 PN-EN IEC 62271-200:2022-02/A1:2025-04 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | IEC 62271-200:2021 | IEC 62271-200:2021/AMD1:2024 | PN-EN IEC 62271-200:2022-02","methodology_zh":"接通与分断能力","test_object_zh":"额定电压至 52 kV 的金属封闭交流成套开关设备 AC metal-enclosed"},{"_id":"6a5dc9adf1c10c8ce825ac68","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Rozdzielnice prądu przemiennego w osłonach metalowych na napięcia znamionowe do 52 kV AC metal-enclosed","test_object_en":"AC metal-enclosed switchgear and controlgear for rated voltages up to 52 kV","methodology":"Odporność na działanie łuku elektrycznego","methodology_en":"Resistance to electric arc","parameters":[{"name":"Zakres","range":"do 31,5 kA"}],"parameters_en":[{"name":"Range","range":"do 31,5 kA"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na działanie łuku elektrycznego\nZakres do 31,5 kA","reference":"PN-EN IEC 62271-200:2022-02/A1:2025-04 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | IEC 62271-200:2021 | IEC 62271-200:2021/AMD1:2024 | PN-EN IEC 62271-200:2022-02","norm_bases":["PN-EN IEC 62271-200:2022-02/A1:2025-04","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-1:2017","IEC 62271-1:2017/AMD1:2021","IEC 62271-200:2021","IEC 62271-200:2021/AMD1:2024","PN-EN IEC 62271-200:2022-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rozdzielnice prądu przemiennego w osłonach metalowych na napięcia znamionowe do 52 kV AC metal-enclosed Odporność na działanie łuku elektrycznego\nZakres do 31,5 kA PN-EN IEC 62271-200:2022-02/A1:2025-04 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | IEC 62271-200:2021 | IEC 62271-200:2021/AMD1:2024 | PN-EN IEC 62271-200:2022-02 Rozdzielnice pradu przemiennego w oslonach metalowych na napiecia znamionowe do 52 kV AC metal-enclosed Odpornosc na dzialanie luku elektrycznego\nZakres do 31,5 kA PN-EN IEC 62271-200:2022-02/A1:2025-04 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | IEC 62271-200:2021 | IEC 62271-200:2021/AMD1:2024 | PN-EN IEC 62271-200:2022-02","categories":["materials"],"row_index":46,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"AC metal-enclosed switchgear and controlgear for rated voltages up to 52 kV Resistance to electric arc Range PN-EN IEC 62271-200:2022-02/A1:2025-04 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | IEC 62271-200:2021 | IEC 62271-200:2021/AMD1:2024 | PN-EN IEC 62271-200:2022-02","parameters_zh":[{"name":"范围","range":"do 31,5 kA"}],"search_zh":"额定电压至 52 kV 的金属封闭交流成套开关设备 AC metal-enclosed 耐电弧作用性 范围 PN-EN IEC 62271-200:2022-02/A1:2025-04 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | IEC 62271-200:2021 | IEC 62271-200:2021/AMD1:2024 | PN-EN IEC 62271-200:2022-02","methodology_zh":"耐电弧作用性","test_object_zh":"额定电压至 52 kV 的金属封闭交流成套开关设备 AC metal-enclosed"},{"_id":"6a5dc9adf1c10c8ce825ac69","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Rozdzielnice prądu przemiennego w osłonach metalowych na napięcia znamionowe do 52 kV AC metal-enclosed","test_object_en":"AC metal-enclosed switchgear and controlgear for rated voltages up to 52 kV","methodology":"Graniczne przyrosty temperatury","methodology_en":"Temperature-rise limits","parameters":[{"name":"Zakres","range":"do 20 kA"},{"name":"Próby nagrzewania prądem długotrwałym"}],"parameters_en":[{"name":"Range","range":"do 20 kA"},{"name":"Temperature-rise tests with continuous current"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Graniczne przyrosty temperatury\nZakres:\nZakres do 20 kA\nPróby nagrzewania prądem długotrwałym","reference":"PN-EN IEC 62271-200:2022-02/A1:2025-04 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | IEC 62271-200:2021 | IEC 62271-200:2021/AMD1:2024 | PN-EN IEC 62271-200:2022-02","norm_bases":["PN-EN IEC 62271-200:2022-02/A1:2025-04","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-1:2017","IEC 62271-1:2017/AMD1:2021","IEC 62271-200:2021","IEC 62271-200:2021/AMD1:2024","PN-EN IEC 62271-200:2022-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rozdzielnice prądu przemiennego w osłonach metalowych na napięcia znamionowe do 52 kV AC metal-enclosed Graniczne przyrosty temperatury\nZakres:\nZakres do 20 kA\nPróby nagrzewania prądem długotrwałym PN-EN IEC 62271-200:2022-02/A1:2025-04 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | IEC 62271-200:2021 | IEC 62271-200:2021/AMD1:2024 | PN-EN IEC 62271-200:2022-02 Rozdzielnice pradu przemiennego w oslonach metalowych na napiecia znamionowe do 52 kV AC metal-enclosed Graniczne przyrosty temperatury\nZakres:\nZakres do 20 kA\nProby nagrzewania pradem dlugotrwalym PN-EN IEC 62271-200:2022-02/A1:2025-04 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | IEC 62271-200:2021 | IEC 62271-200:2021/AMD1:2024 | PN-EN IEC 62271-200:2022-02","categories":["materials"],"row_index":47,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"AC metal-enclosed switchgear and controlgear for rated voltages up to 52 kV Temperature-rise limits Range Temperature-rise tests with continuous current PN-EN IEC 62271-200:2022-02/A1:2025-04 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | IEC 62271-200:2021 | IEC 62271-200:2021/AMD1:2024 | PN-EN IEC 62271-200:2022-02","parameters_zh":[{"name":"范围","range":"do 20 kA"},{"name":"长时间电流温升试验"}],"search_zh":"额定电压至 52 kV 的金属封闭交流成套开关设备 AC metal-enclosed 温升限值 范围 长时间电流温升试验 PN-EN IEC 62271-200:2022-02/A1:2025-04 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | IEC 62271-200:2021 | IEC 62271-200:2021/AMD1:2024 | PN-EN IEC 62271-200:2022-02","methodology_zh":"温升限值","test_object_zh":"额定电压至 52 kV 的金属封闭交流成套开关设备 AC metal-enclosed"},{"_id":"6a5dc9adf1c10c8ce825ac6a","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Rozdzielnice prądu przemiennego w osłonach metalowych na napięcia znamionowe do 52 kV AC metal-enclosed","test_object_en":"AC metal-enclosed switchgear and controlgear for rated voltages up to 52 kV","methodology":"Rezystancja","methodology_en":"Resistance","parameters":[{"name":"Zakres od 10-5 Ω"},{"name":"Prąd probierczy","range":"do 200 A"},{"name":"Rezystancja toru głównego"}],"parameters_en":[{"name":"Range from 10-5 Ω"},{"name":"Test current","range":"do 200 A"},{"name":"Resistance of the main circuit"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Rezystancja\nZakres:\nZakres od 10-5 Ω\nPrąd probierczy do 200 A\nRezystancja toru głównego","reference":"PN-EN IEC 62271-200:2022-02/A1:2025-04 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | IEC 62271-200:2021 | IEC 62271-200:2021/AMD1:2024 | PN-EN IEC 62271-200:2022-02","norm_bases":["PN-EN IEC 62271-200:2022-02/A1:2025-04","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-1:2017","IEC 62271-1:2017/AMD1:2021","IEC 62271-200:2021","IEC 62271-200:2021/AMD1:2024","PN-EN IEC 62271-200:2022-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rozdzielnice prądu przemiennego w osłonach metalowych na napięcia znamionowe do 52 kV AC metal-enclosed Rezystancja\nZakres:\nZakres od 10-5 Ω\nPrąd probierczy do 200 A\nRezystancja toru głównego PN-EN IEC 62271-200:2022-02/A1:2025-04 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | IEC 62271-200:2021 | IEC 62271-200:2021/AMD1:2024 | PN-EN IEC 62271-200:2022-02 Rozdzielnice pradu przemiennego w oslonach metalowych na napiecia znamionowe do 52 kV AC metal-enclosed Rezystancja\nZakres:\nZakres od 10-5 Ω\nPrad probierczy do 200 A\nRezystancja toru glownego PN-EN IEC 62271-200:2022-02/A1:2025-04 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | IEC 62271-200:2021 | IEC 62271-200:2021/AMD1:2024 | PN-EN IEC 62271-200:2022-02","categories":["materials"],"row_index":48,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"AC metal-enclosed switchgear and controlgear for rated voltages up to 52 kV Resistance Range from 10-5 Ω Test current Resistance of the main circuit PN-EN IEC 62271-200:2022-02/A1:2025-04 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | IEC 62271-200:2021 | IEC 62271-200:2021/AMD1:2024 | PN-EN IEC 62271-200:2022-02","methodology_zh":"电阻","search_zh":"额定电压至 52 kV 的金属封闭交流成套开关设备 AC metal-enclosed 电阻 范围自 10-5 Ω 起 试验电流 主回路电阻 PN-EN IEC 62271-200:2022-02/A1:2025-04 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | IEC 62271-200:2021 | IEC 62271-200:2021/AMD1:2024 | PN-EN IEC 62271-200:2022-02","parameters_zh":[{"name":"范围自 10-5 Ω 起"},{"name":"试验电流","range":"do 200 A"},{"name":"主回路电阻"}],"test_object_zh":"额定电压至 52 kV 的金属封闭交流成套开关设备 AC metal-enclosed"},{"_id":"6a5dc9adf1c10c8ce825ac6b","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Rozdzielnice prądu przemiennego w osłonach metalowych na napięcia znamionowe do 52 kV AC metal-enclosed","test_object_en":"AC metal-enclosed switchgear and controlgear for rated voltages up to 52 kV","methodology":"Działanie mechaniczne, Mechanical operation","methodology_en":"Mechanical operation","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Działanie mechaniczne, Mechanical operation","reference":"PN-EN IEC 62271-200:2022-02/A1:2025-04 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | IEC 62271-200:2021 | IEC 62271-200:2021/AMD1:2024 | PN-EN IEC 62271-200:2022-02","norm_bases":["PN-EN IEC 62271-200:2022-02/A1:2025-04","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-1:2017","IEC 62271-1:2017/AMD1:2021","IEC 62271-200:2021","IEC 62271-200:2021/AMD1:2024","PN-EN IEC 62271-200:2022-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rozdzielnice prądu przemiennego w osłonach metalowych na napięcia znamionowe do 52 kV AC metal-enclosed Działanie mechaniczne, Mechanical operation PN-EN IEC 62271-200:2022-02/A1:2025-04 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | IEC 62271-200:2021 | IEC 62271-200:2021/AMD1:2024 | PN-EN IEC 62271-200:2022-02 Rozdzielnice pradu przemiennego w oslonach metalowych na napiecia znamionowe do 52 kV AC metal-enclosed Dzialanie mechaniczne, Mechanical operation PN-EN IEC 62271-200:2022-02/A1:2025-04 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | IEC 62271-200:2021 | IEC 62271-200:2021/AMD1:2024 | PN-EN IEC 62271-200:2022-02","categories":["materials"],"row_index":49,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"AC metal-enclosed switchgear and controlgear for rated voltages up to 52 kV Mechanical operation PN-EN IEC 62271-200:2022-02/A1:2025-04 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | IEC 62271-200:2021 | IEC 62271-200:2021/AMD1:2024 | PN-EN IEC 62271-200:2022-02","search_zh":"额定电压至 52 kV 的金属封闭交流成套开关设备 AC metal-enclosed PN-EN IEC 62271-200:2022-02/A1:2025-04 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | IEC 62271-200:2021 | IEC 62271-200:2021/AMD1:2024 | PN-EN IEC 62271-200:2022-02","test_object_zh":"额定电压至 52 kV 的金属封闭交流成套开关设备 AC metal-enclosed"},{"_id":"6a5dc9adf1c10c8ce825ac6c","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Rozdzielnice prądu przemiennego w osłonach izolacyjnych na napięcia znamionowe do 52 kV AC insulation-enclosed","test_object_en":"AC insulation-enclosed switchgear and controlgear for rated voltages up to 52 kV","methodology":"Wytrzymałość zwarciowa","methodology_en":"Short-circuit withstand strength","parameters":[{"name":"Zakres","range":"do 150 kA rms / 400 kA peak"}],"parameters_en":[{"name":"Range","range":"do 150 kA rms / 400 kA peak"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość zwarciowa\nZakres do 150 kA rms / 400 kA peak","reference":"PN-EN 62271-201:2014 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-201:2014 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021","norm_bases":["PN-EN 62271-201:2014","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-201:2014","IEC 62271-1:2017","IEC 62271-1:2017/AMD1:2021"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rozdzielnice prądu przemiennego w osłonach izolacyjnych na napięcia znamionowe do 52 kV AC insulation-enclosed Wytrzymałość zwarciowa\nZakres do 150 kA rms / 400 kA peak PN-EN 62271-201:2014 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-201:2014 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 Rozdzielnice pradu przemiennego w oslonach izolacyjnych na napiecia znamionowe do 52 kV AC insulation-enclosed Wytrzymalosc zwarciowa\nZakres do 150 kA rms / 400 kA peak PN-EN 62271-201:2014 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-201:2014 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021","categories":["construction"],"row_index":50,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"AC insulation-enclosed switchgear and controlgear for rated voltages up to 52 kV Short-circuit withstand strength Range PN-EN 62271-201:2014 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-201:2014 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021","parameters_zh":[{"name":"范围","range":"do 150 kA rms / 400 kA peak"}],"search_zh":"额定电压至 52 kV 的绝缘封闭交流成套开关设备 AC insulation-enclosed 短路耐受强度 范围 PN-EN 62271-201:2014 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-201:2014 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021","methodology_zh":"短路耐受强度","test_object_zh":"额定电压至 52 kV 的绝缘封闭交流成套开关设备 AC insulation-enclosed"},{"_id":"6a5dc9adf1c10c8ce825ac6d","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Rozdzielnice prądu przemiennego w osłonach izolacyjnych na napięcia znamionowe do 52 kV AC insulation-enclosed","test_object_en":"AC insulation-enclosed switchgear and controlgear for rated voltages up to 52 kV","methodology":"Zdolność łączenia","methodology_en":"Switching capability","parameters":[{"name":"do","range":"do 36 kV"}],"parameters_en":[{"name":"to","range":"do 36 kV"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Zdolność łączenia\ndo do 36 kV","reference":"PN-EN 62271-201:2014 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-201:2014 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021","norm_bases":["PN-EN 62271-201:2014","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-201:2014","IEC 62271-1:2017","IEC 62271-1:2017/AMD1:2021"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rozdzielnice prądu przemiennego w osłonach izolacyjnych na napięcia znamionowe do 52 kV AC insulation-enclosed Zdolność łączenia\ndo do 36 kV PN-EN 62271-201:2014 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-201:2014 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 Rozdzielnice pradu przemiennego w oslonach izolacyjnych na napiecia znamionowe do 52 kV AC insulation-enclosed Zdolnosc laczenia\ndo do 36 kV PN-EN 62271-201:2014 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-201:2014 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021","categories":["construction"],"row_index":51,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"AC insulation-enclosed switchgear and controlgear for rated voltages up to 52 kV Switching capability to PN-EN 62271-201:2014 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-201:2014 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021","methodology_zh":"接通与分断能力","search_zh":"额定电压至 52 kV 的绝缘封闭交流成套开关设备 AC insulation-enclosed 接通与分断能力 PN-EN 62271-201:2014 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-201:2014 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021","test_object_zh":"额定电压至 52 kV 的绝缘封闭交流成套开关设备 AC insulation-enclosed"},{"_id":"6a5dc9adf1c10c8ce825ac6e","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Rozdzielnice prądu przemiennego w osłonach izolacyjnych na napięcia znamionowe do 52 kV AC insulation-enclosed","test_object_en":"AC insulation-enclosed switchgear and controlgear for rated voltages up to 52 kV","methodology":"Odporność na działanie łuku elektrycznego","methodology_en":"Resistance to electric arc","parameters":[{"name":"Zakres","range":"do 31,5 kA"}],"parameters_en":[{"name":"Range","range":"do 31,5 kA"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na działanie łuku elektrycznego\nZakres do 31,5 kA","reference":"PN-EN 62271-201:2014 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-201:2014 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021","norm_bases":["PN-EN 62271-201:2014","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-201:2014","IEC 62271-1:2017","IEC 62271-1:2017/AMD1:2021"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rozdzielnice prądu przemiennego w osłonach izolacyjnych na napięcia znamionowe do 52 kV AC insulation-enclosed Odporność na działanie łuku elektrycznego\nZakres do 31,5 kA PN-EN 62271-201:2014 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-201:2014 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 Rozdzielnice pradu przemiennego w oslonach izolacyjnych na napiecia znamionowe do 52 kV AC insulation-enclosed Odpornosc na dzialanie luku elektrycznego\nZakres do 31,5 kA PN-EN 62271-201:2014 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-201:2014 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021","categories":["construction"],"row_index":52,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"AC insulation-enclosed switchgear and controlgear for rated voltages up to 52 kV Resistance to electric arc Range PN-EN 62271-201:2014 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-201:2014 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021","parameters_zh":[{"name":"范围","range":"do 31,5 kA"}],"search_zh":"额定电压至 52 kV 的绝缘封闭交流成套开关设备 AC insulation-enclosed 耐电弧作用性 范围 PN-EN 62271-201:2014 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-201:2014 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021","methodology_zh":"耐电弧作用性","test_object_zh":"额定电压至 52 kV 的绝缘封闭交流成套开关设备 AC insulation-enclosed"},{"_id":"6a5dc9adf1c10c8ce825ac6f","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Rozdzielnice prądu przemiennego w osłonach izolacyjnych na napięcia znamionowe do 52 kV AC insulation-enclosed","test_object_en":"AC insulation-enclosed switchgear and controlgear for rated voltages up to 52 kV","methodology":"Graniczne przyrosty temperatury","methodology_en":"Temperature-rise limits","parameters":[{"name":"Zakres","range":"do 20 kA"},{"name":"Próby nagrzewania prądem długotrwałym"}],"parameters_en":[{"name":"Range","range":"do 20 kA"},{"name":"Temperature-rise tests with continuous current"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Graniczne przyrosty temperatury\nZakres:\nZakres do 20 kA\nPróby nagrzewania prądem długotrwałym","reference":"PN-EN 62271-201:2014 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-201:2014 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021","norm_bases":["PN-EN 62271-201:2014","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-201:2014","IEC 62271-1:2017","IEC 62271-1:2017/AMD1:2021"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rozdzielnice prądu przemiennego w osłonach izolacyjnych na napięcia znamionowe do 52 kV AC insulation-enclosed Graniczne przyrosty temperatury\nZakres:\nZakres do 20 kA\nPróby nagrzewania prądem długotrwałym PN-EN 62271-201:2014 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-201:2014 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 Rozdzielnice pradu przemiennego w oslonach izolacyjnych na napiecia znamionowe do 52 kV AC insulation-enclosed Graniczne przyrosty temperatury\nZakres:\nZakres do 20 kA\nProby nagrzewania pradem dlugotrwalym PN-EN 62271-201:2014 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-201:2014 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021","categories":["construction"],"row_index":53,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"AC insulation-enclosed switchgear and controlgear for rated voltages up to 52 kV Temperature-rise limits Range Temperature-rise tests with continuous current PN-EN 62271-201:2014 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-201:2014 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021","parameters_zh":[{"name":"范围","range":"do 20 kA"},{"name":"长时间电流温升试验"}],"search_zh":"额定电压至 52 kV 的绝缘封闭交流成套开关设备 AC insulation-enclosed 温升限值 范围 长时间电流温升试验 PN-EN 62271-201:2014 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-201:2014 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021","methodology_zh":"温升限值","test_object_zh":"额定电压至 52 kV 的绝缘封闭交流成套开关设备 AC insulation-enclosed"},{"_id":"6a5dc9adf1c10c8ce825ac70","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Rozdzielnice prądu przemiennego w osłonach izolacyjnych na napięcia znamionowe do 52 kV AC insulation-enclosed","test_object_en":"AC insulation-enclosed switchgear and controlgear for rated voltages up to 52 kV","methodology":"Rezystancja","methodology_en":"Resistance","parameters":[{"name":"Zakres od 10-5 Ω"},{"name":"Prąd probierczy","range":"do 200 A"},{"name":"Rezystancja toru głównego"}],"parameters_en":[{"name":"Range from 10-5 Ω"},{"name":"Test current","range":"do 200 A"},{"name":"Resistance of the main circuit"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Rezystancja\nZakres:\nZakres od 10-5 Ω\nPrąd probierczy do 200 A\nRezystancja toru głównego","reference":"PN-EN 62271-201:2014 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-201:2014 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021","norm_bases":["PN-EN 62271-201:2014","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-201:2014","IEC 62271-1:2017","IEC 62271-1:2017/AMD1:2021"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rozdzielnice prądu przemiennego w osłonach izolacyjnych na napięcia znamionowe do 52 kV AC insulation-enclosed Rezystancja\nZakres:\nZakres od 10-5 Ω\nPrąd probierczy do 200 A\nRezystancja toru głównego PN-EN 62271-201:2014 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-201:2014 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 Rozdzielnice pradu przemiennego w oslonach izolacyjnych na napiecia znamionowe do 52 kV AC insulation-enclosed Rezystancja\nZakres:\nZakres od 10-5 Ω\nPrad probierczy do 200 A\nRezystancja toru glownego PN-EN 62271-201:2014 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-201:2014 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021","categories":["construction"],"row_index":54,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"AC insulation-enclosed switchgear and controlgear for rated voltages up to 52 kV Resistance Range from 10-5 Ω Test current Resistance of the main circuit PN-EN 62271-201:2014 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-201:2014 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021","methodology_zh":"电阻","search_zh":"额定电压至 52 kV 的绝缘封闭交流成套开关设备 AC insulation-enclosed 电阻 范围自 10-5 Ω 起 试验电流 主回路电阻 PN-EN 62271-201:2014 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-201:2014 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021","parameters_zh":[{"name":"范围自 10-5 Ω 起"},{"name":"试验电流","range":"do 200 A"},{"name":"主回路电阻"}],"test_object_zh":"额定电压至 52 kV 的绝缘封闭交流成套开关设备 AC insulation-enclosed"},{"_id":"6a5dc9adf1c10c8ce825ac71","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Rozdzielnice prądu przemiennego w osłonach izolacyjnych na napięcia znamionowe do 52 kV AC insulation-enclosed","test_object_en":"AC insulation-enclosed switchgear and controlgear for rated voltages up to 52 kV","methodology":"Działanie mechaniczne, Mechanical operation","methodology_en":"Mechanical operation","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Działanie mechaniczne, Mechanical operation","reference":"PN-EN 62271-201:2014 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-201:2014 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021","norm_bases":["PN-EN 62271-201:2014","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-201:2014","IEC 62271-1:2017","IEC 62271-1:2017/AMD1:2021"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rozdzielnice prądu przemiennego w osłonach izolacyjnych na napięcia znamionowe do 52 kV AC insulation-enclosed Działanie mechaniczne, Mechanical operation PN-EN 62271-201:2014 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-201:2014 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 Rozdzielnice pradu przemiennego w oslonach izolacyjnych na napiecia znamionowe do 52 kV AC insulation-enclosed Dzialanie mechaniczne, Mechanical operation PN-EN 62271-201:2014 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-201:2014 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021","categories":["construction"],"row_index":55,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"AC insulation-enclosed switchgear and controlgear for rated voltages up to 52 kV Mechanical operation PN-EN 62271-201:2014 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-201:2014 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021","search_zh":"额定电压至 52 kV 的绝缘封闭交流成套开关设备 AC insulation-enclosed PN-EN 62271-201:2014 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-201:2014 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021","test_object_zh":"额定电压至 52 kV 的绝缘封闭交流成套开关设备 AC insulation-enclosed"},{"_id":"6a5dc9adf1c10c8ce825ac72","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Rozdzielnice z izolacją gazową w osłonach metalowych na napięcia znamionowe wyższe niż 52 kV, Gas-insulated metal-","test_object_en":"Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV","methodology":"Wytrzymałość zwarciowa","methodology_en":"Short-circuit withstand strength","parameters":[{"name":"Zakres","range":"do 150 kA rms / 400 kA peak"}],"parameters_en":[{"name":"Range","range":"do 150 kA rms / 400 kA peak"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość zwarciowa\nZakres do 150 kA rms / 400 kA peak","reference":"PN-EN IEC 62271-203:2023-02 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-203:2022 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021","norm_bases":["PN-EN IEC 62271-203:2023-02","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-203:2022","IEC 62271-1:2017","IEC 62271-1:2017/AMD1:2021"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rozdzielnice z izolacją gazową w osłonach metalowych na napięcia znamionowe wyższe niż 52 kV, Gas-insulated metal- Wytrzymałość zwarciowa\nZakres do 150 kA rms / 400 kA peak PN-EN IEC 62271-203:2023-02 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-203:2022 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 Rozdzielnice z izolacja gazowa w oslonach metalowych na napiecia znamionowe wyzsze niz 52 kV, Gas-insulated metal- Wytrzymalosc zwarciowa\nZakres do 150 kA rms / 400 kA peak PN-EN IEC 62271-203:2023-02 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-203:2022 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021","categories":["materials","construction"],"row_index":56,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV Short-circuit withstand strength Range PN-EN IEC 62271-203:2023-02 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-203:2022 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021","parameters_zh":[{"name":"范围","range":"do 150 kA rms / 400 kA peak"}],"search_zh":"短路耐受强度 范围 PN-EN IEC 62271-203:2023-02 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-203:2022 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021","methodology_zh":"短路耐受强度"},{"_id":"6a5dc9adf1c10c8ce825ac73","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Rozdzielnice z izolacją gazową w osłonach metalowych na napięcia znamionowe wyższe niż 52 kV, Gas-insulated metal-","test_object_en":"Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV","methodology":"Odporność na działanie łuku elektrycznego","methodology_en":"Resistance to electric arc","parameters":[{"name":"Zakres","range":"do 40 kA"}],"parameters_en":[{"name":"Range","range":"do 40 kA"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na działanie łuku elektrycznego\nZakres do 40 kA","reference":"PN-EN IEC 62271-203:2023-02 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-203:2022 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021","norm_bases":["PN-EN IEC 62271-203:2023-02","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-203:2022","IEC 62271-1:2017","IEC 62271-1:2017/AMD1:2021"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rozdzielnice z izolacją gazową w osłonach metalowych na napięcia znamionowe wyższe niż 52 kV, Gas-insulated metal- Odporność na działanie łuku elektrycznego\nZakres do 40 kA PN-EN IEC 62271-203:2023-02 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-203:2022 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 Rozdzielnice z izolacja gazowa w oslonach metalowych na napiecia znamionowe wyzsze niz 52 kV, Gas-insulated metal- Odpornosc na dzialanie luku elektrycznego\nZakres do 40 kA PN-EN IEC 62271-203:2023-02 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-203:2022 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021","categories":["materials","construction"],"row_index":57,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV Resistance to electric arc Range PN-EN IEC 62271-203:2023-02 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-203:2022 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021","parameters_zh":[{"name":"范围","range":"do 40 kA"}],"search_zh":"耐电弧作用性 范围 PN-EN IEC 62271-203:2023-02 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-203:2022 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021","methodology_zh":"耐电弧作用性"},{"_id":"6a5dc9adf1c10c8ce825ac74","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Prefabrykowane stacje napięcia przemiennego AC prefabricated substations","test_object_en":"AC prefabricated substations","methodology":"Wytrzymałość zwarciowa","methodology_en":"Short-circuit withstand strength","parameters":[{"name":"Zakres","range":"do 150 kA rms / 400 kA peak"},{"name":"Short-circuit tests Range: up and including to 150 kA rms / 400 kA peak Odporność na działanie łuku elektrycznego"},{"name":"Zakres","range":"do 31,5 kA"}],"parameters_en":[{"name":"Range","range":"do 150 kA rms / 400 kA peak"},{"name":"Short-circuit tests Range: up and including to 150 kA rms / 400 kA peak Resistance to electric arc"},{"name":"Range","range":"do 31,5 kA"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość zwarciowa\nZakres:\nZakres do 150 kA rms / 400 kA peak\nShort-circuit tests Range: up and including to 150 kA rms / 400 kA peak Odporność na działanie łuku elektrycznego\nZakres do 31,5 kA","reference":"PN-EN IEC 62271-202:2023-03 | PN-EN IEC 62271-202:2023-03/AC:2023-10E | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | PN-EN 62262:2003 | PN-EN 62262:2003/A1:2022-06 | IEC 62262:2002 | IEC 62262:2002/AMD1:2021 | PN-EN 60529:2003 | PN-EN 60529:2003/A2:2014-07 | IEC 60529:1989 | IEC 60529:1989/AMD1:1999 | IEC 60529:1989/AMD2:2013 | IEC 62271-202:2022","norm_bases":["PN-EN IEC 62271-202:2023-03","PN-EN IEC 62271-202:2023-03/AC:2023-10E","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-1:2017","IEC 62271-1:2017/AMD1:2021","PN-EN 62262:2003","PN-EN 62262:2003/A1:2022-06","IEC 62262:2002","IEC 62262:2002/AMD1:2021","PN-EN 60529:2003","PN-EN 60529:2003/A2:2014-07","IEC 60529:1989","IEC 60529:1989/AMD1:1999","IEC 60529:1989/AMD2:2013","IEC 62271-202:2022"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Prefabrykowane stacje napięcia przemiennego AC prefabricated substations Wytrzymałość zwarciowa\nZakres:\nZakres do 150 kA rms / 400 kA peak\nShort-circuit tests Range: up and including to 150 kA rms / 400 kA peak Odporność na działanie łuku elektrycznego\nZakres do 31,5 kA PN-EN IEC 62271-202:2023-03 | PN-EN IEC 62271-202:2023-03/AC:2023-10E | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | PN-EN 62262:2003 | PN-EN 62262:2003/A1:2022-06 | IEC 62262:2002 | IEC 62262:2002/AMD1:2021 | PN-EN 60529:2003 | PN-EN 60529:2003/A2:2014-07 | IEC 60529:1989 | IEC 60529:1989/AMD1:1999 | IEC 60529:1989/AMD2:2013 | IEC 62271-202:2022 Prefabrykowane stacje napiecia przemiennego AC prefabricated substations Wytrzymalosc zwarciowa\nZakres:\nZakres do 150 kA rms / 400 kA peak\nShort-circuit tests Range: up and including to 150 kA rms / 400 kA peak Odpornosc na dzialanie luku elektrycznego\nZakres do 31,5 kA PN-EN IEC 62271-202:2023-03 | PN-EN IEC 62271-202:2023-03/AC:2023-10E | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | PN-EN 62262:2003 | PN-EN 62262:2003/A1:2022-06 | IEC 62262:2002 | IEC 62262:2002/AMD1:2021 | PN-EN 60529:2003 | PN-EN 60529:2003/A2:2014-07 | IEC 60529:1989 | IEC 60529:1989/AMD1:1999 | IEC 60529:1989/AMD2:2013 | IEC 62271-202:2022","categories":["other"],"row_index":58,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"AC prefabricated substations Short-circuit withstand strength Range Short-circuit tests Range: up and including to 150 kA rms / 400 kA peak Resistance to electric arc Range PN-EN IEC 62271-202:2023-03 | PN-EN IEC 62271-202:2023-03/AC:2023-10E | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | PN-EN 62262:2003 | PN-EN 62262:2003/A1:2022-06 | IEC 62262:2002 | IEC 62262:2002/AMD1:2021 | PN-EN 60529:2003 | PN-EN 60529:2003/A2:2014-07 | IEC 60529:1989 | IEC 60529:1989/AMD1:1999 | IEC 60529:1989/AMD2:2013 | IEC 62271-202:2022","parameters_zh":[{"name":"范围","range":"do 150 kA rms / 400 kA peak"},{"name":"Short-circuit tests Range: up and including to 150 kA rms / 400 kA peak Odporność na działanie łuku elektrycznego"},{"name":"范围","range":"do 31,5 kA"}],"search_zh":"交流预装式变电站 AC prefabricated substations 短路耐受强度 范围 范围 PN-EN IEC 62271-202:2023-03 | PN-EN IEC 62271-202:2023-03/AC:2023-10E | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | PN-EN 62262:2003 | PN-EN 62262:2003/A1:2022-06 | IEC 62262:2002 | IEC 62262:2002/AMD1:2021 | PN-EN 60529:2003 | PN-EN 60529:2003/A2:2014-07 | IEC 60529:1989 | IEC 60529:1989/AMD1:1999 | IEC 60529:1989/AMD2:2013 | IEC 62271-202:2022","methodology_zh":"短路耐受强度","test_object_zh":"交流预装式变电站 AC prefabricated substations"},{"_id":"6a5dc9adf1c10c8ce825ac75","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Prefabrykowane stacje napięcia przemiennego AC prefabricated substations","test_object_en":"AC prefabricated substations","methodology":"Graniczne przyrosty temperatury","methodology_en":"Temperature-rise limits","parameters":[{"name":"Zakres","range":"do 4 kA (obwód z transformatorem)"},{"name":"Próby nagrzewania prądem długotrwałym"}],"parameters_en":[{"name":"Range","range":"do 4 kA (obwód z transformatorem)"},{"name":"Temperature-rise tests with continuous current"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Graniczne przyrosty temperatury\nZakres:\nZakres do 4 kA (obwód z transformatorem)\nPróby nagrzewania prądem długotrwałym","reference":"PN-EN IEC 62271-202:2023-03 | PN-EN IEC 62271-202:2023-03/AC:2023-10E | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | PN-EN 62262:2003 | PN-EN 62262:2003/A1:2022-06 | IEC 62262:2002 | IEC 62262:2002/AMD1:2021 | PN-EN 60529:2003 | PN-EN 60529:2003/A2:2014-07 | IEC 60529:1989 | IEC 60529:1989/AMD1:1999 | IEC 60529:1989/AMD2:2013 | IEC 62271-202:2022","norm_bases":["PN-EN IEC 62271-202:2023-03","PN-EN IEC 62271-202:2023-03/AC:2023-10E","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-1:2017","IEC 62271-1:2017/AMD1:2021","PN-EN 62262:2003","PN-EN 62262:2003/A1:2022-06","IEC 62262:2002","IEC 62262:2002/AMD1:2021","PN-EN 60529:2003","PN-EN 60529:2003/A2:2014-07","IEC 60529:1989","IEC 60529:1989/AMD1:1999","IEC 60529:1989/AMD2:2013","IEC 62271-202:2022"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Prefabrykowane stacje napięcia przemiennego AC prefabricated substations Graniczne przyrosty temperatury\nZakres:\nZakres do 4 kA (obwód z transformatorem)\nPróby nagrzewania prądem długotrwałym PN-EN IEC 62271-202:2023-03 | PN-EN IEC 62271-202:2023-03/AC:2023-10E | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | PN-EN 62262:2003 | PN-EN 62262:2003/A1:2022-06 | IEC 62262:2002 | IEC 62262:2002/AMD1:2021 | PN-EN 60529:2003 | PN-EN 60529:2003/A2:2014-07 | IEC 60529:1989 | IEC 60529:1989/AMD1:1999 | IEC 60529:1989/AMD2:2013 | IEC 62271-202:2022 Prefabrykowane stacje napiecia przemiennego AC prefabricated substations Graniczne przyrosty temperatury\nZakres:\nZakres do 4 kA (obwod z transformatorem)\nProby nagrzewania pradem dlugotrwalym PN-EN IEC 62271-202:2023-03 | PN-EN IEC 62271-202:2023-03/AC:2023-10E | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | PN-EN 62262:2003 | PN-EN 62262:2003/A1:2022-06 | IEC 62262:2002 | IEC 62262:2002/AMD1:2021 | PN-EN 60529:2003 | PN-EN 60529:2003/A2:2014-07 | IEC 60529:1989 | IEC 60529:1989/AMD1:1999 | IEC 60529:1989/AMD2:2013 | IEC 62271-202:2022","categories":["other"],"row_index":59,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"AC prefabricated substations Temperature-rise limits Range Temperature-rise tests with continuous current PN-EN IEC 62271-202:2023-03 | PN-EN IEC 62271-202:2023-03/AC:2023-10E | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | PN-EN 62262:2003 | PN-EN 62262:2003/A1:2022-06 | IEC 62262:2002 | IEC 62262:2002/AMD1:2021 | PN-EN 60529:2003 | PN-EN 60529:2003/A2:2014-07 | IEC 60529:1989 | IEC 60529:1989/AMD1:1999 | IEC 60529:1989/AMD2:2013 | IEC 62271-202:2022","parameters_zh":[{"name":"范围","range":"do 4 kA (obwód z transformatorem)"},{"name":"长时间电流温升试验"}],"search_zh":"交流预装式变电站 AC prefabricated substations 温升限值 范围 长时间电流温升试验 PN-EN IEC 62271-202:2023-03 | PN-EN IEC 62271-202:2023-03/AC:2023-10E | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | PN-EN 62262:2003 | PN-EN 62262:2003/A1:2022-06 | IEC 62262:2002 | IEC 62262:2002/AMD1:2021 | PN-EN 60529:2003 | PN-EN 60529:2003/A2:2014-07 | IEC 60529:1989 | IEC 60529:1989/AMD1:1999 | IEC 60529:1989/AMD2:2013 | IEC 62271-202:2022","methodology_zh":"温升限值","test_object_zh":"交流预装式变电站 AC prefabricated substations"},{"_id":"6a5dc9adf1c10c8ce825ac76","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Prefabrykowane stacje napięcia przemiennego AC prefabricated substations","test_object_en":"AC prefabricated substations","methodology":"Sprawdzenie kodu IK","methodology_en":"Verification of the IK code","parameters":[{"name":"Zakres","range":"IK07, IK09, IK10"}],"parameters_en":[{"name":"Range","range":"IK07, IK09, IK10"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Sprawdzenie kodu IK\nZakres IK07, IK09, IK10","reference":"PN-EN IEC 62271-202:2023-03 | PN-EN IEC 62271-202:2023-03/AC:2023-10E | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | PN-EN 62262:2003 | PN-EN 62262:2003/A1:2022-06 | IEC 62262:2002 | IEC 62262:2002/AMD1:2021 | PN-EN 60529:2003 | PN-EN 60529:2003/A2:2014-07 | IEC 60529:1989 | IEC 60529:1989/AMD1:1999 | IEC 60529:1989/AMD2:2013 | IEC 62271-202:2022","norm_bases":["PN-EN IEC 62271-202:2023-03","PN-EN IEC 62271-202:2023-03/AC:2023-10E","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-1:2017","IEC 62271-1:2017/AMD1:2021","PN-EN 62262:2003","PN-EN 62262:2003/A1:2022-06","IEC 62262:2002","IEC 62262:2002/AMD1:2021","PN-EN 60529:2003","PN-EN 60529:2003/A2:2014-07","IEC 60529:1989","IEC 60529:1989/AMD1:1999","IEC 60529:1989/AMD2:2013","IEC 62271-202:2022"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Prefabrykowane stacje napięcia przemiennego AC prefabricated substations Sprawdzenie kodu IK\nZakres IK07, IK09, IK10 PN-EN IEC 62271-202:2023-03 | PN-EN IEC 62271-202:2023-03/AC:2023-10E | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | PN-EN 62262:2003 | PN-EN 62262:2003/A1:2022-06 | IEC 62262:2002 | IEC 62262:2002/AMD1:2021 | PN-EN 60529:2003 | PN-EN 60529:2003/A2:2014-07 | IEC 60529:1989 | IEC 60529:1989/AMD1:1999 | IEC 60529:1989/AMD2:2013 | IEC 62271-202:2022 Prefabrykowane stacje napiecia przemiennego AC prefabricated substations Sprawdzenie kodu IK\nZakres IK07, IK09, IK10 PN-EN IEC 62271-202:2023-03 | PN-EN IEC 62271-202:2023-03/AC:2023-10E | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | PN-EN 62262:2003 | PN-EN 62262:2003/A1:2022-06 | IEC 62262:2002 | IEC 62262:2002/AMD1:2021 | PN-EN 60529:2003 | PN-EN 60529:2003/A2:2014-07 | IEC 60529:1989 | IEC 60529:1989/AMD1:1999 | IEC 60529:1989/AMD2:2013 | IEC 62271-202:2022","categories":["other"],"row_index":60,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"AC prefabricated substations Verification of the IK code Range PN-EN IEC 62271-202:2023-03 | PN-EN IEC 62271-202:2023-03/AC:2023-10E | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | PN-EN 62262:2003 | PN-EN 62262:2003/A1:2022-06 | IEC 62262:2002 | IEC 62262:2002/AMD1:2021 | PN-EN 60529:2003 | PN-EN 60529:2003/A2:2014-07 | IEC 60529:1989 | IEC 60529:1989/AMD1:1999 | IEC 60529:1989/AMD2:2013 | IEC 62271-202:2022","parameters_zh":[{"name":"范围","range":"IK07, IK09, IK10"}],"search_zh":"交流预装式变电站 AC prefabricated substations 范围 PN-EN IEC 62271-202:2023-03 | PN-EN IEC 62271-202:2023-03/AC:2023-10E | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | PN-EN 62262:2003 | PN-EN 62262:2003/A1:2022-06 | IEC 62262:2002 | IEC 62262:2002/AMD1:2021 | PN-EN 60529:2003 | PN-EN 60529:2003/A2:2014-07 | IEC 60529:1989 | IEC 60529:1989/AMD1:1999 | IEC 60529:1989/AMD2:2013 | IEC 62271-202:2022","test_object_zh":"交流预装式变电站 AC prefabricated substations"},{"_id":"6a5dc9adf1c10c8ce825ac77","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Prefabrykowane stacje napięcia przemiennego AC prefabricated substations","test_object_en":"AC prefabricated substations","methodology":"Stopień ochrony","methodology_en":"Degree of protection","parameters":[{"name":"Zakres","range":"do IP45"}],"parameters_en":[{"name":"Range","range":"do IP45"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stopień ochrony\nZakres do IP45","reference":"PN-EN IEC 62271-202:2023-03 | PN-EN IEC 62271-202:2023-03/AC:2023-10E | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | PN-EN 62262:2003 | PN-EN 62262:2003/A1:2022-06 | IEC 62262:2002 | IEC 62262:2002/AMD1:2021 | PN-EN 60529:2003 | PN-EN 60529:2003/A2:2014-07 | IEC 60529:1989 | IEC 60529:1989/AMD1:1999 | IEC 60529:1989/AMD2:2013 | IEC 62271-202:2022","norm_bases":["PN-EN IEC 62271-202:2023-03","PN-EN IEC 62271-202:2023-03/AC:2023-10E","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-1:2017","IEC 62271-1:2017/AMD1:2021","PN-EN 62262:2003","PN-EN 62262:2003/A1:2022-06","IEC 62262:2002","IEC 62262:2002/AMD1:2021","PN-EN 60529:2003","PN-EN 60529:2003/A2:2014-07","IEC 60529:1989","IEC 60529:1989/AMD1:1999","IEC 60529:1989/AMD2:2013","IEC 62271-202:2022"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Prefabrykowane stacje napięcia przemiennego AC prefabricated substations Stopień ochrony\nZakres do IP45 PN-EN IEC 62271-202:2023-03 | PN-EN IEC 62271-202:2023-03/AC:2023-10E | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | PN-EN 62262:2003 | PN-EN 62262:2003/A1:2022-06 | IEC 62262:2002 | IEC 62262:2002/AMD1:2021 | PN-EN 60529:2003 | PN-EN 60529:2003/A2:2014-07 | IEC 60529:1989 | IEC 60529:1989/AMD1:1999 | IEC 60529:1989/AMD2:2013 | IEC 62271-202:2022 Prefabrykowane stacje napiecia przemiennego AC prefabricated substations Stopien ochrony\nZakres do IP45 PN-EN IEC 62271-202:2023-03 | PN-EN IEC 62271-202:2023-03/AC:2023-10E | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | PN-EN 62262:2003 | PN-EN 62262:2003/A1:2022-06 | IEC 62262:2002 | IEC 62262:2002/AMD1:2021 | PN-EN 60529:2003 | PN-EN 60529:2003/A2:2014-07 | IEC 60529:1989 | IEC 60529:1989/AMD1:1999 | IEC 60529:1989/AMD2:2013 | IEC 62271-202:2022","categories":["other"],"row_index":61,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"AC prefabricated substations Degree of protection Range PN-EN IEC 62271-202:2023-03 | PN-EN IEC 62271-202:2023-03/AC:2023-10E | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | PN-EN 62262:2003 | PN-EN 62262:2003/A1:2022-06 | IEC 62262:2002 | IEC 62262:2002/AMD1:2021 | PN-EN 60529:2003 | PN-EN 60529:2003/A2:2014-07 | IEC 60529:1989 | IEC 60529:1989/AMD1:1999 | IEC 60529:1989/AMD2:2013 | IEC 62271-202:2022","parameters_zh":[{"name":"范围","range":"do IP45"}],"search_zh":"交流预装式变电站 AC prefabricated substations 范围 PN-EN IEC 62271-202:2023-03 | PN-EN IEC 62271-202:2023-03/AC:2023-10E | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | PN-EN 62262:2003 | PN-EN 62262:2003/A1:2022-06 | IEC 62262:2002 | IEC 62262:2002/AMD1:2021 | PN-EN 60529:2003 | PN-EN 60529:2003/A2:2014-07 | IEC 60529:1989 | IEC 60529:1989/AMD1:1999 | IEC 60529:1989/AMD2:2013 | IEC 62271-202:2022","test_object_zh":"交流预装式变电站 AC prefabricated substations"},{"_id":"6a5dc9adf1c10c8ce825ac78","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Aparatura rozdzielcza w osłonach metalowych instalowana na słupach na napięcia powyżej 1 kV do 52 kV włącznie, Metal-enclosed pole-","test_object_en":"Metal-enclosed switchgear mounted on poles for rated voltages above 1 kV up to and including 52 kV","methodology":"Odporność na działanie łuku elektrycznego","methodology_en":"Resistance to electric arc","parameters":[{"name":"Zakres","range":"do 31,5 kA"}],"parameters_en":[{"name":"Range","range":"do 31,5 kA"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na działanie łuku elektrycznego\nZakres do 31,5 kA","reference":"PN-EN IEC 62271-214:2025-01 | PN-EN IEC 62271-214:2025-01/AC:2025-06E | IEC 62271-214:2024 | IEC 62271-214:2024/COR1:2025","norm_bases":["PN-EN IEC 62271-214:2025-01","PN-EN IEC 62271-214:2025-01/AC:2025-06E","IEC 62271-214:2024","IEC 62271-214:2024/COR1:2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Aparatura rozdzielcza w osłonach metalowych instalowana na słupach na napięcia powyżej 1 kV do 52 kV włącznie, Metal-enclosed pole- Odporność na działanie łuku elektrycznego\nZakres do 31,5 kA PN-EN IEC 62271-214:2025-01 | PN-EN IEC 62271-214:2025-01/AC:2025-06E | IEC 62271-214:2024 | IEC 62271-214:2024/COR1:2025 Aparatura rozdzielcza w oslonach metalowych instalowana na slupach na napiecia powyzej 1 kV do 52 kV wlacznie, Metal-enclosed pole- Odpornosc na dzialanie luku elektrycznego\nZakres do 31,5 kA PN-EN IEC 62271-214:2025-01 | PN-EN IEC 62271-214:2025-01/AC:2025-06E | IEC 62271-214:2024 | IEC 62271-214:2024/COR1:2025","categories":["materials"],"row_index":62,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Metal-enclosed switchgear mounted on poles for rated voltages above 1 kV up to and including 52 kV Resistance to electric arc Range PN-EN IEC 62271-214:2025-01 | PN-EN IEC 62271-214:2025-01/AC:2025-06E | IEC 62271-214:2024 | IEC 62271-214:2024/COR1:2025","parameters_zh":[{"name":"范围","range":"do 31,5 kA"}],"search_zh":"耐电弧作用性 范围 PN-EN IEC 62271-214:2025-01 | PN-EN IEC 62271-214:2025-01/AC:2025-06E | IEC 62271-214:2024 | IEC 62271-214:2024/COR1:2025","methodology_zh":"耐电弧作用性"},{"_id":"6a5dc9adf1c10c8ce825ac79","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Transformatory energetyczne o napięciu GN do 36 kV i specjalne o napięciu GN do 120 kV","test_object_en":"Power transformers with HV voltage up to 36 kV and special transformers with HV voltage up to 120 kV","methodology":"Wytrzymałość dynamiczna","methodology_en":"Dynamic strength","parameters":[{"name":"Zakres","range":"do 50 kA"}],"parameters_en":[{"name":"Range","range":"do 50 kA"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość dynamiczna\nZakres do 50 kA","reference":"PN-EN 60076-5:2009 | PN-EN IEC 60076-11:2019-01 | IEC 60076-5:2006 | IEC 60076-11:2018 | PN-EN 60076-2:2011 | IEC 60076-2:2011","norm_bases":["PN-EN 60076-5:2009","PN-EN IEC 60076-11:2019-01","IEC 60076-5:2006","IEC 60076-11:2018","PN-EN 60076-2:2011","IEC 60076-2:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Transformatory energetyczne o napięciu GN do 36 kV i specjalne o napięciu GN do 120 kV Wytrzymałość dynamiczna\nZakres do 50 kA PN-EN 60076-5:2009 | PN-EN IEC 60076-11:2019-01 | IEC 60076-5:2006 | IEC 60076-11:2018 | PN-EN 60076-2:2011 | IEC 60076-2:2011 Transformatory energetyczne o napieciu GN do 36 kV i specjalne o napieciu GN do 120 kV Wytrzymalosc dynamiczna\nZakres do 50 kA PN-EN 60076-5:2009 | PN-EN IEC 60076-11:2019-01 | IEC 60076-5:2006 | IEC 60076-11:2018 | PN-EN 60076-2:2011 | IEC 60076-2:2011","categories":["other"],"row_index":63,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Power transformers with HV voltage up to 36 kV and special transformers with HV voltage up to 120 kV Dynamic strength Range PN-EN 60076-5:2009 | PN-EN IEC 60076-11:2019-01 | IEC 60076-5:2006 | IEC 60076-11:2018 | PN-EN 60076-2:2011 | IEC 60076-2:2011","parameters_zh":[{"name":"范围","range":"do 50 kA"}],"search_zh":"范围 PN-EN 60076-5:2009 | PN-EN IEC 60076-11:2019-01 | IEC 60076-5:2006 | IEC 60076-11:2018 | PN-EN 60076-2:2011 | IEC 60076-2:2011"},{"_id":"6a5dc9adf1c10c8ce825ac7a","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Transformatory energetyczne o napięciu GN do 36 kV i specjalne o napięciu GN do 120 kV","test_object_en":"Power transformers with HV voltage up to 36 kV and special transformers with HV voltage up to 120 kV","methodology":"Graniczne przyrosty temperatury","methodology_en":"Temperature-rise limits","parameters":[{"name":"Zakres","range":"do 4 kA"},{"name":"Próby nagrzewania prądem długotrwałym"}],"parameters_en":[{"name":"Range","range":"do 4 kA"},{"name":"Temperature-rise tests with continuous current"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Graniczne przyrosty temperatury\nZakres:\nZakres do 4 kA\nPróby nagrzewania prądem długotrwałym","reference":"PN-EN 60076-5:2009 | PN-EN IEC 60076-11:2019-01 | IEC 60076-5:2006 | IEC 60076-11:2018 | PN-EN 60076-2:2011 | IEC 60076-2:2011","norm_bases":["PN-EN 60076-5:2009","PN-EN IEC 60076-11:2019-01","IEC 60076-5:2006","IEC 60076-11:2018","PN-EN 60076-2:2011","IEC 60076-2:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Transformatory energetyczne o napięciu GN do 36 kV i specjalne o napięciu GN do 120 kV Graniczne przyrosty temperatury\nZakres:\nZakres do 4 kA\nPróby nagrzewania prądem długotrwałym PN-EN 60076-5:2009 | PN-EN IEC 60076-11:2019-01 | IEC 60076-5:2006 | IEC 60076-11:2018 | PN-EN 60076-2:2011 | IEC 60076-2:2011 Transformatory energetyczne o napieciu GN do 36 kV i specjalne o napieciu GN do 120 kV Graniczne przyrosty temperatury\nZakres:\nZakres do 4 kA\nProby nagrzewania pradem dlugotrwalym PN-EN 60076-5:2009 | PN-EN IEC 60076-11:2019-01 | IEC 60076-5:2006 | IEC 60076-11:2018 | PN-EN 60076-2:2011 | IEC 60076-2:2011","categories":["other"],"row_index":64,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Power transformers with HV voltage up to 36 kV and special transformers with HV voltage up to 120 kV Temperature-rise limits Range Temperature-rise tests with continuous current PN-EN 60076-5:2009 | PN-EN IEC 60076-11:2019-01 | IEC 60076-5:2006 | IEC 60076-11:2018 | PN-EN 60076-2:2011 | IEC 60076-2:2011","parameters_zh":[{"name":"范围","range":"do 4 kA"},{"name":"长时间电流温升试验"}],"search_zh":"温升限值 范围 长时间电流温升试验 PN-EN 60076-5:2009 | PN-EN IEC 60076-11:2019-01 | IEC 60076-5:2006 | IEC 60076-11:2018 | PN-EN 60076-2:2011 | IEC 60076-2:2011","methodology_zh":"温升限值"},{"_id":"6a5dc9adf1c10c8ce825ac7b","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Transformatory energetyczne o napięciu GN do 36 kV i specjalne o napięciu GN do 120 kV","test_object_en":"Power transformers with HV voltage up to 36 kV and special transformers with HV voltage up to 120 kV","methodology":"Rezystancja uzwojeń","methodology_en":"Resistance of windings","parameters":[{"name":"Zakres","range":"od 10-5Ω"}],"parameters_en":[{"name":"Range","range":"od 10-5Ω"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Rezystancja uzwojeń\nZakres od 10-5Ω","reference":"PN-EN 60076-5:2009 | PN-EN IEC 60076-11:2019-01 | IEC 60076-5:2006 | IEC 60076-11:2018 | PN-EN 60076-2:2011 | IEC 60076-2:2011","norm_bases":["PN-EN 60076-5:2009","PN-EN IEC 60076-11:2019-01","IEC 60076-5:2006","IEC 60076-11:2018","PN-EN 60076-2:2011","IEC 60076-2:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Transformatory energetyczne o napięciu GN do 36 kV i specjalne o napięciu GN do 120 kV Rezystancja uzwojeń\nZakres od 10-5Ω PN-EN 60076-5:2009 | PN-EN IEC 60076-11:2019-01 | IEC 60076-5:2006 | IEC 60076-11:2018 | PN-EN 60076-2:2011 | IEC 60076-2:2011 Transformatory energetyczne o napieciu GN do 36 kV i specjalne o napieciu GN do 120 kV Rezystancja uzwojen\nZakres od 10-5Ω PN-EN 60076-5:2009 | PN-EN IEC 60076-11:2019-01 | IEC 60076-5:2006 | IEC 60076-11:2018 | PN-EN 60076-2:2011 | IEC 60076-2:2011","categories":["other"],"row_index":65,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Power transformers with HV voltage up to 36 kV and special transformers with HV voltage up to 120 kV Resistance of windings Range PN-EN 60076-5:2009 | PN-EN IEC 60076-11:2019-01 | IEC 60076-5:2006 | IEC 60076-11:2018 | PN-EN 60076-2:2011 | IEC 60076-2:2011","parameters_zh":[{"name":"范围","range":"od 10-5Ω"}],"search_zh":"范围 PN-EN 60076-5:2009 | PN-EN IEC 60076-11:2019-01 | IEC 60076-5:2006 | IEC 60076-11:2018 | PN-EN 60076-2:2011 | IEC 60076-2:2011"},{"_id":"6a5dc9adf1c10c8ce825ac7c","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Ograniczniki przepięć do 123 kV","test_object_en":"Surge arresters up to 123 kV","methodology":"Wytrzymałość zwarciowa","methodology_en":"Short-circuit withstand strength","parameters":[{"name":"Zakres","range":"do 40 kA"}],"parameters_en":[{"name":"Range","range":"do 40 kA"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość zwarciowa\nZakres do 40 kA","reference":"PN-EN 60099-4:2015-01 | IEC 60099-4:2014","norm_bases":["PN-EN 60099-4:2015-01","IEC 60099-4:2014"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ograniczniki przepięć do 123 kV Wytrzymałość zwarciowa\nZakres do 40 kA PN-EN 60099-4:2015-01 | IEC 60099-4:2014 Ograniczniki przepiec do 123 kV Wytrzymalosc zwarciowa\nZakres do 40 kA PN-EN 60099-4:2015-01 | IEC 60099-4:2014","categories":["other"],"row_index":66,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Surge arresters up to 123 kV Short-circuit withstand strength Range PN-EN 60099-4:2015-01 | IEC 60099-4:2014","parameters_zh":[{"name":"范围","range":"do 40 kA"}],"search_zh":"短路耐受强度 范围 PN-EN 60099-4:2015-01 | IEC 60099-4:2014","methodology_zh":"短路耐受强度"},{"_id":"6a5dc9adf1c10c8ce825ac7d","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Wyłączniki wysokonapięciowe prądu przemiennego o napięciu znamionowym do 36 kV, Alternating-current circuit-breakers","test_object_en":"High-voltage alternating-current circuit-breakers with rated voltage up to 36 kV","methodology":"Wytrzymałość zwarciowa","methodology_en":"Short-circuit withstand strength","parameters":[{"name":"Zakres","range":"do 150 kA rms / 400 kA peak"}],"parameters_en":[{"name":"Range","range":"do 150 kA rms / 400 kA peak"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość zwarciowa\nZakres do 150 kA rms / 400 kA peak","reference":"PN-EN IEC 62271-100:2022-04/A1:2025-05 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | PN-EN IEC 62271-100:2022-04 | IEC 62271-100:2021 | IEC 62271-100:2021/AMD1:2024","norm_bases":["PN-EN IEC 62271-100:2022-04/A1:2025-05","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-1:2017","IEC 62271-1:2017/AMD1:2021","PN-EN IEC 62271-100:2022-04","IEC 62271-100:2021","IEC 62271-100:2021/AMD1:2024"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyłączniki wysokonapięciowe prądu przemiennego o napięciu znamionowym do 36 kV, Alternating-current circuit-breakers Wytrzymałość zwarciowa\nZakres do 150 kA rms / 400 kA peak PN-EN IEC 62271-100:2022-04/A1:2025-05 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | PN-EN IEC 62271-100:2022-04 | IEC 62271-100:2021 | IEC 62271-100:2021/AMD1:2024 Wylaczniki wysokonapieciowe pradu przemiennego o napieciu znamionowym do 36 kV, Alternating-current circuit-breakers Wytrzymalosc zwarciowa\nZakres do 150 kA rms / 400 kA peak PN-EN IEC 62271-100:2022-04/A1:2025-05 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | PN-EN IEC 62271-100:2022-04 | IEC 62271-100:2021 | IEC 62271-100:2021/AMD1:2024","categories":["other"],"row_index":67,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"High-voltage alternating-current circuit-breakers with rated voltage up to 36 kV Short-circuit withstand strength Range PN-EN IEC 62271-100:2022-04/A1:2025-05 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | PN-EN IEC 62271-100:2022-04 | IEC 62271-100:2021 | IEC 62271-100:2021/AMD1:2024","parameters_zh":[{"name":"范围","range":"do 150 kA rms / 400 kA peak"}],"search_zh":"额定电压至 36 kV 的高压交流断路器 Alternating-current circuit-breakers 短路耐受强度 范围 PN-EN IEC 62271-100:2022-04/A1:2025-05 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | PN-EN IEC 62271-100:2022-04 | IEC 62271-100:2021 | IEC 62271-100:2021/AMD1:2024","methodology_zh":"短路耐受强度","test_object_zh":"额定电压至 36 kV 的高压交流断路器 Alternating-current circuit-breakers"},{"_id":"6a5dc9adf1c10c8ce825ac7e","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Wyłączniki wysokonapięciowe prądu przemiennego o napięciu znamionowym do 36 kV, Alternating-current circuit-breakers","test_object_en":"High-voltage alternating-current circuit-breakers with rated voltage up to 36 kV","methodology":"Zdolność łączenia","methodology_en":"Switching capability","parameters":[{"name":"Zakres","range":"do 36 kV"}],"parameters_en":[{"name":"Range","range":"do 36 kV"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Zdolność łączenia\nZakres do 36 kV","reference":"PN-EN IEC 62271-100:2022-04/A1:2025-05 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | PN-EN IEC 62271-100:2022-04 | IEC 62271-100:2021 | IEC 62271-100:2021/AMD1:2024","norm_bases":["PN-EN IEC 62271-100:2022-04/A1:2025-05","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-1:2017","IEC 62271-1:2017/AMD1:2021","PN-EN IEC 62271-100:2022-04","IEC 62271-100:2021","IEC 62271-100:2021/AMD1:2024"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyłączniki wysokonapięciowe prądu przemiennego o napięciu znamionowym do 36 kV, Alternating-current circuit-breakers Zdolność łączenia\nZakres do 36 kV PN-EN IEC 62271-100:2022-04/A1:2025-05 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | PN-EN IEC 62271-100:2022-04 | IEC 62271-100:2021 | IEC 62271-100:2021/AMD1:2024 Wylaczniki wysokonapieciowe pradu przemiennego o napieciu znamionowym do 36 kV, Alternating-current circuit-breakers Zdolnosc laczenia\nZakres do 36 kV PN-EN IEC 62271-100:2022-04/A1:2025-05 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | PN-EN IEC 62271-100:2022-04 | IEC 62271-100:2021 | IEC 62271-100:2021/AMD1:2024","categories":["other"],"row_index":68,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"High-voltage alternating-current circuit-breakers with rated voltage up to 36 kV Switching capability Range PN-EN IEC 62271-100:2022-04/A1:2025-05 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | PN-EN IEC 62271-100:2022-04 | IEC 62271-100:2021 | IEC 62271-100:2021/AMD1:2024","parameters_zh":[{"name":"范围","range":"do 36 kV"}],"search_zh":"额定电压至 36 kV 的高压交流断路器 Alternating-current circuit-breakers 接通与分断能力 范围 PN-EN IEC 62271-100:2022-04/A1:2025-05 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | PN-EN IEC 62271-100:2022-04 | IEC 62271-100:2021 | IEC 62271-100:2021/AMD1:2024","methodology_zh":"接通与分断能力","test_object_zh":"额定电压至 36 kV 的高压交流断路器 Alternating-current circuit-breakers"},{"_id":"6a5dc9adf1c10c8ce825ac7f","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Wyłączniki wysokonapięciowe prądu przemiennego o napięciu znamionowym do 36 kV, Alternating-current circuit-breakers","test_object_en":"High-voltage alternating-current circuit-breakers with rated voltage up to 36 kV","methodology":"Działanie mechaniczne, trwałość mechaniczna, Mechanical operation, Mechanical endurance","methodology_en":"Mechanical operation, mechanical endurance, Mechanical operation, Mechanical endurance","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Działanie mechaniczne, trwałość mechaniczna, Mechanical operation, Mechanical endurance","reference":"PN-EN IEC 62271-100:2022-04/A1:2025-05 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | PN-EN IEC 62271-100:2022-04 | IEC 62271-100:2021 | IEC 62271-100:2021/AMD1:2024","norm_bases":["PN-EN IEC 62271-100:2022-04/A1:2025-05","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-1:2017","IEC 62271-1:2017/AMD1:2021","PN-EN IEC 62271-100:2022-04","IEC 62271-100:2021","IEC 62271-100:2021/AMD1:2024"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyłączniki wysokonapięciowe prądu przemiennego o napięciu znamionowym do 36 kV, Alternating-current circuit-breakers Działanie mechaniczne, trwałość mechaniczna, Mechanical operation, Mechanical endurance PN-EN IEC 62271-100:2022-04/A1:2025-05 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | PN-EN IEC 62271-100:2022-04 | IEC 62271-100:2021 | IEC 62271-100:2021/AMD1:2024 Wylaczniki wysokonapieciowe pradu przemiennego o napieciu znamionowym do 36 kV, Alternating-current circuit-breakers Dzialanie mechaniczne, trwalosc mechaniczna, Mechanical operation, Mechanical endurance PN-EN IEC 62271-100:2022-04/A1:2025-05 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | PN-EN IEC 62271-100:2022-04 | IEC 62271-100:2021 | IEC 62271-100:2021/AMD1:2024","categories":["other"],"row_index":69,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"High-voltage alternating-current circuit-breakers with rated voltage up to 36 kV Mechanical operation, mechanical endurance, Mechanical operation, Mechanical endurance PN-EN IEC 62271-100:2022-04/A1:2025-05 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | PN-EN IEC 62271-100:2022-04 | IEC 62271-100:2021 | IEC 62271-100:2021/AMD1:2024","search_zh":"额定电压至 36 kV 的高压交流断路器 Alternating-current circuit-breakers PN-EN IEC 62271-100:2022-04/A1:2025-05 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | PN-EN IEC 62271-100:2022-04 | IEC 62271-100:2021 | IEC 62271-100:2021/AMD1:2024","test_object_zh":"额定电压至 36 kV 的高压交流断路器 Alternating-current circuit-breakers"},{"_id":"6a5dc9adf1c10c8ce825ac80","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Wyłączniki wysokonapięciowe prądu przemiennego o napięciu znamionowym do 36 kV, Alternating-current circuit-breakers","test_object_en":"High-voltage alternating-current circuit-breakers with rated voltage up to 36 kV","methodology":"Graniczne przyrosty temperatury","methodology_en":"Temperature-rise limits","parameters":[{"name":"Zakres","range":"do 20 kA"},{"name":"Próby nagrzewania prądem długotrwałym"}],"parameters_en":[{"name":"Range","range":"do 20 kA"},{"name":"Temperature-rise tests with continuous current"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Graniczne przyrosty temperatury\nZakres:\nZakres do 20 kA\nPróby nagrzewania prądem długotrwałym","reference":"PN-EN IEC 62271-100:2022-04/A1:2025-05 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | PN-EN IEC 62271-100:2022-04 | IEC 62271-100:2021 | IEC 62271-100:2021/AMD1:2024","norm_bases":["PN-EN IEC 62271-100:2022-04/A1:2025-05","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-1:2017","IEC 62271-1:2017/AMD1:2021","PN-EN IEC 62271-100:2022-04","IEC 62271-100:2021","IEC 62271-100:2021/AMD1:2024"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyłączniki wysokonapięciowe prądu przemiennego o napięciu znamionowym do 36 kV, Alternating-current circuit-breakers Graniczne przyrosty temperatury\nZakres:\nZakres do 20 kA\nPróby nagrzewania prądem długotrwałym PN-EN IEC 62271-100:2022-04/A1:2025-05 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | PN-EN IEC 62271-100:2022-04 | IEC 62271-100:2021 | IEC 62271-100:2021/AMD1:2024 Wylaczniki wysokonapieciowe pradu przemiennego o napieciu znamionowym do 36 kV, Alternating-current circuit-breakers Graniczne przyrosty temperatury\nZakres:\nZakres do 20 kA\nProby nagrzewania pradem dlugotrwalym PN-EN IEC 62271-100:2022-04/A1:2025-05 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | PN-EN IEC 62271-100:2022-04 | IEC 62271-100:2021 | IEC 62271-100:2021/AMD1:2024","categories":["other"],"row_index":70,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"High-voltage alternating-current circuit-breakers with rated voltage up to 36 kV Temperature-rise limits Range Temperature-rise tests with continuous current PN-EN IEC 62271-100:2022-04/A1:2025-05 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | PN-EN IEC 62271-100:2022-04 | IEC 62271-100:2021 | IEC 62271-100:2021/AMD1:2024","parameters_zh":[{"name":"范围","range":"do 20 kA"},{"name":"长时间电流温升试验"}],"search_zh":"额定电压至 36 kV 的高压交流断路器 Alternating-current circuit-breakers 温升限值 范围 长时间电流温升试验 PN-EN IEC 62271-100:2022-04/A1:2025-05 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | PN-EN IEC 62271-100:2022-04 | IEC 62271-100:2021 | IEC 62271-100:2021/AMD1:2024","methodology_zh":"温升限值","test_object_zh":"额定电压至 36 kV 的高压交流断路器 Alternating-current circuit-breakers"},{"_id":"6a5dc9adf1c10c8ce825ac81","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Wyłączniki wysokonapięciowe prądu przemiennego o napięciu znamionowym do 36 kV, Alternating-current circuit-breakers","test_object_en":"High-voltage alternating-current circuit-breakers with rated voltage up to 36 kV","methodology":"Rezystancja","methodology_en":"Resistance","parameters":[{"name":"Zakres od 10-5 Ω"},{"name":"Prąd probierczy","range":"do 200 A"},{"name":"Rezystancja toru głównego"}],"parameters_en":[{"name":"Range from 10-5 Ω"},{"name":"Test current","range":"do 200 A"},{"name":"Resistance of the main circuit"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Rezystancja\nZakres:\nZakres od 10-5 Ω\nPrąd probierczy do 200 A\nRezystancja toru głównego","reference":"PN-EN IEC 62271-100:2022-04/A1:2025-05 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | PN-EN IEC 62271-100:2022-04 | IEC 62271-100:2021 | IEC 62271-100:2021/AMD1:2024","norm_bases":["PN-EN IEC 62271-100:2022-04/A1:2025-05","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-1:2017","IEC 62271-1:2017/AMD1:2021","PN-EN IEC 62271-100:2022-04","IEC 62271-100:2021","IEC 62271-100:2021/AMD1:2024"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyłączniki wysokonapięciowe prądu przemiennego o napięciu znamionowym do 36 kV, Alternating-current circuit-breakers Rezystancja\nZakres:\nZakres od 10-5 Ω\nPrąd probierczy do 200 A\nRezystancja toru głównego PN-EN IEC 62271-100:2022-04/A1:2025-05 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | PN-EN IEC 62271-100:2022-04 | IEC 62271-100:2021 | IEC 62271-100:2021/AMD1:2024 Wylaczniki wysokonapieciowe pradu przemiennego o napieciu znamionowym do 36 kV, Alternating-current circuit-breakers Rezystancja\nZakres:\nZakres od 10-5 Ω\nPrad probierczy do 200 A\nRezystancja toru glownego PN-EN IEC 62271-100:2022-04/A1:2025-05 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | PN-EN IEC 62271-100:2022-04 | IEC 62271-100:2021 | IEC 62271-100:2021/AMD1:2024","categories":["other"],"row_index":71,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"High-voltage alternating-current circuit-breakers with rated voltage up to 36 kV Resistance Range from 10-5 Ω Test current Resistance of the main circuit PN-EN IEC 62271-100:2022-04/A1:2025-05 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | PN-EN IEC 62271-100:2022-04 | IEC 62271-100:2021 | IEC 62271-100:2021/AMD1:2024","methodology_zh":"电阻","search_zh":"额定电压至 36 kV 的高压交流断路器 Alternating-current circuit-breakers 电阻 范围自 10-5 Ω 起 试验电流 主回路电阻 PN-EN IEC 62271-100:2022-04/A1:2025-05 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | PN-EN IEC 62271-100:2022-04 | IEC 62271-100:2021 | IEC 62271-100:2021/AMD1:2024","parameters_zh":[{"name":"范围自 10-5 Ω 起"},{"name":"试验电流","range":"do 200 A"},{"name":"主回路电阻"}],"test_object_zh":"额定电压至 36 kV 的高压交流断路器 Alternating-current circuit-breakers"},{"_id":"6a5dc9adf1c10c8ce825ac82","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Rozłączniki wysokonapięciowe o napięciu znamionowym do 36 kV","test_object_en":"High-voltage switch-disconnectors with rated voltage up to 36 kV","methodology":"Wytrzymałość zwarciowa","methodology_en":"Short-circuit withstand strength","parameters":[{"name":"Zakres","range":"do 150 kA rms / 400 kA peak"}],"parameters_en":[{"name":"Range","range":"do 150 kA rms / 400 kA peak"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość zwarciowa\nZakres do 150 kA rms / 400 kA peak","reference":"PN-EN IEC 62271-103:2024-04 | IEC 62271-103:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 IEEE Std. C37.20.4-2013","norm_bases":["PN-EN IEC 62271-103:2024-04","IEC 62271-103:2021","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-1:2017","IEC 62271-1:2017/AMD1:2021 IEEE Std. C37.20.4-2013"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rozłączniki wysokonapięciowe o napięciu znamionowym do 36 kV Wytrzymałość zwarciowa\nZakres do 150 kA rms / 400 kA peak PN-EN IEC 62271-103:2024-04 | IEC 62271-103:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 IEEE Std. C37.20.4-2013 Rozlaczniki wysokonapieciowe o napieciu znamionowym do 36 kV Wytrzymalosc zwarciowa\nZakres do 150 kA rms / 400 kA peak PN-EN IEC 62271-103:2024-04 | IEC 62271-103:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 IEEE Std. C37.20.4-2013","categories":["other"],"row_index":72,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"High-voltage switch-disconnectors with rated voltage up to 36 kV Short-circuit withstand strength Range PN-EN IEC 62271-103:2024-04 | IEC 62271-103:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 IEEE Std. C37.20.4-2013","parameters_zh":[{"name":"范围","range":"do 150 kA rms / 400 kA peak"}],"search_zh":"额定电压至 36 kV 的高压负荷开关 短路耐受强度 范围 PN-EN IEC 62271-103:2024-04 | IEC 62271-103:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 IEEE Std. C37.20.4-2013","methodology_zh":"短路耐受强度","test_object_zh":"额定电压至 36 kV 的高压负荷开关"},{"_id":"6a5dc9adf1c10c8ce825ac83","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Rozłączniki wysokonapięciowe o napięciu znamionowym do 36 kV","test_object_en":"High-voltage switch-disconnectors with rated voltage up to 36 kV","methodology":"Zdolność łączenia","methodology_en":"Switching capability","parameters":[{"name":"Zakres","range":"do 1600 A"},{"name":"Zdolność załączania na zwarcie"},{"name":"Zakres","range":"do 100 kA wartości szczytowej"}],"parameters_en":[{"name":"Range","range":"do 1600 A"},{"name":"Short-circuit making capacity"},{"name":"Range","range":"do 100 kA wartości szczytowej"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Zdolność łączenia\nZakres:\nZakres do 1600 A\nZdolność załączania na zwarcie\nZakres do 100 kA wartości szczytowej","reference":"PN-EN IEC 62271-103:2024-04 | IEC 62271-103:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 IEEE Std. C37.20.4-2013","norm_bases":["PN-EN IEC 62271-103:2024-04","IEC 62271-103:2021","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-1:2017","IEC 62271-1:2017/AMD1:2021 IEEE Std. C37.20.4-2013"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rozłączniki wysokonapięciowe o napięciu znamionowym do 36 kV Zdolność łączenia\nZakres:\nZakres do 1600 A\nZdolność załączania na zwarcie\nZakres do 100 kA wartości szczytowej PN-EN IEC 62271-103:2024-04 | IEC 62271-103:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 IEEE Std. C37.20.4-2013 Rozlaczniki wysokonapieciowe o napieciu znamionowym do 36 kV Zdolnosc laczenia\nZakres:\nZakres do 1600 A\nZdolnosc zalaczania na zwarcie\nZakres do 100 kA wartosci szczytowej PN-EN IEC 62271-103:2024-04 | IEC 62271-103:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 IEEE Std. C37.20.4-2013","categories":["other"],"row_index":73,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"High-voltage switch-disconnectors with rated voltage up to 36 kV Switching capability Range Short-circuit making capacity Range PN-EN IEC 62271-103:2024-04 | IEC 62271-103:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 IEEE Std. C37.20.4-2013","parameters_zh":[{"name":"范围","range":"do 1600 A"},{"name":"Zdolność załączania na zwarcie"},{"name":"范围","range":"do 100 kA wartości szczytowej"}],"search_zh":"额定电压至 36 kV 的高压负荷开关 接通与分断能力 范围 范围 PN-EN IEC 62271-103:2024-04 | IEC 62271-103:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 IEEE Std. C37.20.4-2013","methodology_zh":"接通与分断能力","test_object_zh":"额定电压至 36 kV 的高压负荷开关"},{"_id":"6a5dc9adf1c10c8ce825ac84","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Rozłączniki wysokonapięciowe o napięciu znamionowym do 36 kV","test_object_en":"High-voltage switch-disconnectors with rated voltage up to 36 kV","methodology":"Działanie mechaniczne, trwałość mechaniczna, Mechanical operation, Mechanical endurance","methodology_en":"Mechanical operation, mechanical endurance, Mechanical operation, Mechanical endurance","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Działanie mechaniczne, trwałość mechaniczna, Mechanical operation, Mechanical endurance","reference":"PN-EN IEC 62271-103:2024-04 | IEC 62271-103:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 IEEE Std. C37.20.4-2013","norm_bases":["PN-EN IEC 62271-103:2024-04","IEC 62271-103:2021","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-1:2017","IEC 62271-1:2017/AMD1:2021 IEEE Std. C37.20.4-2013"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rozłączniki wysokonapięciowe o napięciu znamionowym do 36 kV Działanie mechaniczne, trwałość mechaniczna, Mechanical operation, Mechanical endurance PN-EN IEC 62271-103:2024-04 | IEC 62271-103:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 IEEE Std. C37.20.4-2013 Rozlaczniki wysokonapieciowe o napieciu znamionowym do 36 kV Dzialanie mechaniczne, trwalosc mechaniczna, Mechanical operation, Mechanical endurance PN-EN IEC 62271-103:2024-04 | IEC 62271-103:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 IEEE Std. C37.20.4-2013","categories":["other"],"row_index":74,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"High-voltage switch-disconnectors with rated voltage up to 36 kV Mechanical operation, mechanical endurance, Mechanical operation, Mechanical endurance PN-EN IEC 62271-103:2024-04 | IEC 62271-103:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 IEEE Std. C37.20.4-2013","search_zh":"额定电压至 36 kV 的高压负荷开关 PN-EN IEC 62271-103:2024-04 | IEC 62271-103:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 IEEE Std. C37.20.4-2013","test_object_zh":"额定电压至 36 kV 的高压负荷开关"},{"_id":"6a5dc9adf1c10c8ce825ac85","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Rozłączniki wysokonapięciowe o napięciu znamionowym do 36 kV","test_object_en":"High-voltage switch-disconnectors with rated voltage up to 36 kV","methodology":"Graniczne przyrosty temperatury","methodology_en":"Temperature-rise limits","parameters":[{"name":"Zakres","range":"do 20 kA"},{"name":"Próby nagrzewania prądem długotrwałym"}],"parameters_en":[{"name":"Range","range":"do 20 kA"},{"name":"Temperature-rise tests with continuous current"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Graniczne przyrosty temperatury\nZakres:\nZakres do 20 kA\nPróby nagrzewania prądem długotrwałym","reference":"PN-EN IEC 62271-103:2024-04 | IEC 62271-103:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 IEEE Std. C37.20.4-2013","norm_bases":["PN-EN IEC 62271-103:2024-04","IEC 62271-103:2021","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-1:2017","IEC 62271-1:2017/AMD1:2021 IEEE Std. C37.20.4-2013"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rozłączniki wysokonapięciowe o napięciu znamionowym do 36 kV Graniczne przyrosty temperatury\nZakres:\nZakres do 20 kA\nPróby nagrzewania prądem długotrwałym PN-EN IEC 62271-103:2024-04 | IEC 62271-103:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 IEEE Std. C37.20.4-2013 Rozlaczniki wysokonapieciowe o napieciu znamionowym do 36 kV Graniczne przyrosty temperatury\nZakres:\nZakres do 20 kA\nProby nagrzewania pradem dlugotrwalym PN-EN IEC 62271-103:2024-04 | IEC 62271-103:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 IEEE Std. C37.20.4-2013","categories":["other"],"row_index":75,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"High-voltage switch-disconnectors with rated voltage up to 36 kV Temperature-rise limits Range Temperature-rise tests with continuous current PN-EN IEC 62271-103:2024-04 | IEC 62271-103:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 IEEE Std. C37.20.4-2013","parameters_zh":[{"name":"范围","range":"do 20 kA"},{"name":"长时间电流温升试验"}],"search_zh":"额定电压至 36 kV 的高压负荷开关 温升限值 范围 长时间电流温升试验 PN-EN IEC 62271-103:2024-04 | IEC 62271-103:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 IEEE Std. C37.20.4-2013","methodology_zh":"温升限值","test_object_zh":"额定电压至 36 kV 的高压负荷开关"},{"_id":"6a5dc9adf1c10c8ce825ac86","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Rozłączniki wysokonapięciowe o napięciu znamionowym do 36 kV","test_object_en":"High-voltage switch-disconnectors with rated voltage up to 36 kV","methodology":"Rezystancja","methodology_en":"Resistance","parameters":[{"name":"Zakres od 10-5 Ω"},{"name":"Prąd probierczy","range":"do 200 A"},{"name":"Rezystancja toru głównego"}],"parameters_en":[{"name":"Range from 10-5 Ω"},{"name":"Test current","range":"do 200 A"},{"name":"Resistance of the main circuit"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Rezystancja\nZakres:\nZakres od 10-5 Ω\nPrąd probierczy do 200 A\nRezystancja toru głównego","reference":"PN-EN IEC 62271-103:2024-04 | IEC 62271-103:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 IEEE Std. C37.20.4-2013","norm_bases":["PN-EN IEC 62271-103:2024-04","IEC 62271-103:2021","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-1:2017","IEC 62271-1:2017/AMD1:2021 IEEE Std. C37.20.4-2013"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rozłączniki wysokonapięciowe o napięciu znamionowym do 36 kV Rezystancja\nZakres:\nZakres od 10-5 Ω\nPrąd probierczy do 200 A\nRezystancja toru głównego PN-EN IEC 62271-103:2024-04 | IEC 62271-103:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 IEEE Std. C37.20.4-2013 Rozlaczniki wysokonapieciowe o napieciu znamionowym do 36 kV Rezystancja\nZakres:\nZakres od 10-5 Ω\nPrad probierczy do 200 A\nRezystancja toru glownego PN-EN IEC 62271-103:2024-04 | IEC 62271-103:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 IEEE Std. C37.20.4-2013","categories":["other"],"row_index":76,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"High-voltage switch-disconnectors with rated voltage up to 36 kV Resistance Range from 10-5 Ω Test current Resistance of the main circuit PN-EN IEC 62271-103:2024-04 | IEC 62271-103:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 IEEE Std. C37.20.4-2013","methodology_zh":"电阻","search_zh":"额定电压至 36 kV 的高压负荷开关 电阻 范围自 10-5 Ω 起 试验电流 主回路电阻 PN-EN IEC 62271-103:2024-04 | IEC 62271-103:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 IEEE Std. C37.20.4-2013","parameters_zh":[{"name":"范围自 10-5 Ω 起"},{"name":"试验电流","range":"do 200 A"},{"name":"主回路电阻"}],"test_object_zh":"额定电压至 36 kV 的高压负荷开关"},{"_id":"6a5dc9adf1c10c8ce825ac87","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Wysokonapięciowe zestawy rozłącznikowo-bezpiecznikowe prądu przemiennego o napięciu znamionowym do 36 kV, Alternating current switch-fuse","test_object_en":"High-voltage alternating current switch-fuse combinations with rated voltage up to 36 kV","methodology":"Zdolność łączenia","methodology_en":"Switching capability","parameters":[{"name":"Zakres","range":"do 1600 A"},{"name":"Zdolność załączania na zwarcie"},{"name":"Zakres","range":"do 100 kA wartości szczytowej"}],"parameters_en":[{"name":"Range","range":"do 1600 A"},{"name":"Short-circuit making capacity"},{"name":"Range","range":"do 100 kA wartości szczytowej"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Zdolność łączenia\nZakres:\nZakres do 1600 A\nZdolność załączania na zwarcie\nZakres do 100 kA wartości szczytowej","reference":"PN-EN IEC 62271-105:2024-04 | IEC 62271-105:2021","norm_bases":["PN-EN IEC 62271-105:2024-04","IEC 62271-105:2021"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wysokonapięciowe zestawy rozłącznikowo-bezpiecznikowe prądu przemiennego o napięciu znamionowym do 36 kV, Alternating current switch-fuse Zdolność łączenia\nZakres:\nZakres do 1600 A\nZdolność załączania na zwarcie\nZakres do 100 kA wartości szczytowej PN-EN IEC 62271-105:2024-04 | IEC 62271-105:2021 Wysokonapieciowe zestawy rozlacznikowo-bezpiecznikowe pradu przemiennego o napieciu znamionowym do 36 kV, Alternating current switch-fuse Zdolnosc laczenia\nZakres:\nZakres do 1600 A\nZdolnosc zalaczania na zwarcie\nZakres do 100 kA wartosci szczytowej PN-EN IEC 62271-105:2024-04 | IEC 62271-105:2021","categories":["other"],"row_index":77,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"High-voltage alternating current switch-fuse combinations with rated voltage up to 36 kV Switching capability Range Short-circuit making capacity Range PN-EN IEC 62271-105:2024-04 | IEC 62271-105:2021","parameters_zh":[{"name":"范围","range":"do 1600 A"},{"name":"Zdolność załączania na zwarcie"},{"name":"范围","range":"do 100 kA wartości szczytowej"}],"search_zh":"额定电压至 36 kV 的高压交流熔断器式负荷开关组合电器 Alternating current switch-fuse 接通与分断能力 范围 范围 PN-EN IEC 62271-105:2024-04 | IEC 62271-105:2021","methodology_zh":"接通与分断能力","test_object_zh":"额定电压至 36 kV 的高压交流熔断器式负荷开关组合电器 Alternating current switch-fuse"},{"_id":"6a5dc9adf1c10c8ce825ac88","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Wysokonapięciowe zestawy rozłącznikowo-bezpiecznikowe prądu przemiennego o napięciu znamionowym do 36 kV, Alternating current switch-fuse","test_object_en":"High-voltage alternating current switch-fuse combinations with rated voltage up to 36 kV","methodology":"Działanie mechanizmu, odporność bezpieczników na wstrząsy","methodology_en":"Operation of the mechanism, shock resistance of fuses","parameters":[{"name":"Zakres","range":"do 3 J"},{"name":"Mechanical operation"}],"parameters_en":[{"name":"Range","range":"do 3 J"},{"name":"Mechanical operation"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Działanie mechanizmu, odporność bezpieczników na wstrząsy\nZakres:\nZakres do 3 J\nMechanical operation","reference":"PN-EN IEC 62271-105:2024-04 | IEC 62271-105:2021","norm_bases":["PN-EN IEC 62271-105:2024-04","IEC 62271-105:2021"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wysokonapięciowe zestawy rozłącznikowo-bezpiecznikowe prądu przemiennego o napięciu znamionowym do 36 kV, Alternating current switch-fuse Działanie mechanizmu, odporność bezpieczników na wstrząsy\nZakres:\nZakres do 3 J\nMechanical operation PN-EN IEC 62271-105:2024-04 | IEC 62271-105:2021 Wysokonapieciowe zestawy rozlacznikowo-bezpiecznikowe pradu przemiennego o napieciu znamionowym do 36 kV, Alternating current switch-fuse Dzialanie mechanizmu, odpornosc bezpiecznikow na wstrzasy\nZakres:\nZakres do 3 J\nMechanical operation PN-EN IEC 62271-105:2024-04 | IEC 62271-105:2021","categories":["other"],"row_index":78,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"High-voltage alternating current switch-fuse combinations with rated voltage up to 36 kV Operation of the mechanism, shock resistance of fuses Range Mechanical operation PN-EN IEC 62271-105:2024-04 | IEC 62271-105:2021","parameters_zh":[{"name":"范围","range":"do 3 J"},{"name":"Mechanical operation"}],"search_zh":"额定电压至 36 kV 的高压交流熔断器式负荷开关组合电器 Alternating current switch-fuse 范围 PN-EN IEC 62271-105:2024-04 | IEC 62271-105:2021","test_object_zh":"额定电压至 36 kV 的高压交流熔断器式负荷开关组合电器 Alternating current switch-fuse"},{"_id":"6a5dc9adf1c10c8ce825ac89","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Wysokonapięciowe zestawy rozłącznikowo-bezpiecznikowe prądu przemiennego o napięciu znamionowym do 36 kV, Alternating current switch-fuse","test_object_en":"High-voltage alternating current switch-fuse combinations with rated voltage up to 36 kV","methodology":"Graniczne przyrosty temperatury","methodology_en":"Temperature-rise limits","parameters":[{"name":"Zakres","range":"do 20 kA"},{"name":"Próby nagrzewania prądem długotrwałym"}],"parameters_en":[{"name":"Range","range":"do 20 kA"},{"name":"Temperature-rise tests with continuous current"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Graniczne przyrosty temperatury\nZakres:\nZakres do 20 kA\nPróby nagrzewania prądem długotrwałym","reference":"PN-EN IEC 62271-105:2024-04 | IEC 62271-105:2021","norm_bases":["PN-EN IEC 62271-105:2024-04","IEC 62271-105:2021"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wysokonapięciowe zestawy rozłącznikowo-bezpiecznikowe prądu przemiennego o napięciu znamionowym do 36 kV, Alternating current switch-fuse Graniczne przyrosty temperatury\nZakres:\nZakres do 20 kA\nPróby nagrzewania prądem długotrwałym PN-EN IEC 62271-105:2024-04 | IEC 62271-105:2021 Wysokonapieciowe zestawy rozlacznikowo-bezpiecznikowe pradu przemiennego o napieciu znamionowym do 36 kV, Alternating current switch-fuse Graniczne przyrosty temperatury\nZakres:\nZakres do 20 kA\nProby nagrzewania pradem dlugotrwalym PN-EN IEC 62271-105:2024-04 | IEC 62271-105:2021","categories":["other"],"row_index":79,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"High-voltage alternating current switch-fuse combinations with rated voltage up to 36 kV Temperature-rise limits Range Temperature-rise tests with continuous current PN-EN IEC 62271-105:2024-04 | IEC 62271-105:2021","parameters_zh":[{"name":"范围","range":"do 20 kA"},{"name":"长时间电流温升试验"}],"search_zh":"额定电压至 36 kV 的高压交流熔断器式负荷开关组合电器 Alternating current switch-fuse 温升限值 范围 长时间电流温升试验 PN-EN IEC 62271-105:2024-04 | IEC 62271-105:2021","methodology_zh":"温升限值","test_object_zh":"额定电压至 36 kV 的高压交流熔断器式负荷开关组合电器 Alternating current switch-fuse"},{"_id":"6a5dc9adf1c10c8ce825ac8a","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Wysokonapięciowe zestawy rozłącznikowo-bezpiecznikowe prądu przemiennego o napięciu znamionowym do 36 kV, Alternating current switch-fuse","test_object_en":"High-voltage alternating current switch-fuse combinations with rated voltage up to 36 kV","methodology":"Rezystancja","methodology_en":"Resistance","parameters":[{"name":"Zakres od 10-5 Ω"},{"name":"Prąd probierczy","range":"do 200 A"},{"name":"Rezystancja toru głównego"}],"parameters_en":[{"name":"Range from 10-5 Ω"},{"name":"Test current","range":"do 200 A"},{"name":"Resistance of the main circuit"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Rezystancja\nZakres:\nZakres od 10-5 Ω\nPrąd probierczy do 200 A\nRezystancja toru głównego","reference":"PN-EN IEC 62271-105:2024-04 | IEC 62271-105:2021","norm_bases":["PN-EN IEC 62271-105:2024-04","IEC 62271-105:2021"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wysokonapięciowe zestawy rozłącznikowo-bezpiecznikowe prądu przemiennego o napięciu znamionowym do 36 kV, Alternating current switch-fuse Rezystancja\nZakres:\nZakres od 10-5 Ω\nPrąd probierczy do 200 A\nRezystancja toru głównego PN-EN IEC 62271-105:2024-04 | IEC 62271-105:2021 Wysokonapieciowe zestawy rozlacznikowo-bezpiecznikowe pradu przemiennego o napieciu znamionowym do 36 kV, Alternating current switch-fuse Rezystancja\nZakres:\nZakres od 10-5 Ω\nPrad probierczy do 200 A\nRezystancja toru glownego PN-EN IEC 62271-105:2024-04 | IEC 62271-105:2021","categories":["other"],"row_index":80,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"High-voltage alternating current switch-fuse combinations with rated voltage up to 36 kV Resistance Range from 10-5 Ω Test current Resistance of the main circuit PN-EN IEC 62271-105:2024-04 | IEC 62271-105:2021","methodology_zh":"电阻","search_zh":"额定电压至 36 kV 的高压交流熔断器式负荷开关组合电器 Alternating current switch-fuse 电阻 范围自 10-5 Ω 起 试验电流 主回路电阻 PN-EN IEC 62271-105:2024-04 | IEC 62271-105:2021","parameters_zh":[{"name":"范围自 10-5 Ω 起"},{"name":"试验电流","range":"do 200 A"},{"name":"主回路电阻"}],"test_object_zh":"额定电压至 36 kV 的高压交流熔断器式负荷开关组合电器 Alternating current switch-fuse"},{"_id":"6a5dc9adf1c10c8ce825ac8b","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Odłączniki i uziemniki wysokonapięciowe prądu przemiennego o napięciu znamionowym do 550 kV, Alternating current disconnectors","test_object_en":"Alternating current disconnectors and earthing switches with rated voltage up to 550 kV","methodology":"Wytrzymałość zwarciowa","methodology_en":"Short-circuit withstand strength","parameters":[{"name":"Zakres","range":"do 150 kA rms / 400 kA peak"}],"parameters_en":[{"name":"Range","range":"do 150 kA rms / 400 kA peak"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość zwarciowa\nZakres do 150 kA rms / 400 kA peak","reference":"PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-102:2018 | IEC 62271-102 :2018/AMD1 :2022 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 Scope of accreditation No. AB 324","norm_bases":["PN-EN IEC 62271-102:2018-10","PN-EN IEC 62271-102:2018-10/A1:2023-01","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-102:2018","IEC 62271-102 :2018/AMD1 :2022","IEC 62271-1:2017","IEC 62271-1:2017/AMD1:2021 Scope of accreditation No. AB 324"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odłączniki i uziemniki wysokonapięciowe prądu przemiennego o napięciu znamionowym do 550 kV, Alternating current disconnectors Wytrzymałość zwarciowa\nZakres do 150 kA rms / 400 kA peak PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-102:2018 | IEC 62271-102 :2018/AMD1 :2022 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 Scope of accreditation No. AB 324 Odlaczniki i uziemniki wysokonapieciowe pradu przemiennego o napieciu znamionowym do 550 kV, Alternating current disconnectors Wytrzymalosc zwarciowa\nZakres do 150 kA rms / 400 kA peak PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-102:2018 | IEC 62271-102 :2018/AMD1 :2022 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 Scope of accreditation No. AB 324","categories":["other"],"row_index":81,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Alternating current disconnectors and earthing switches with rated voltage up to 550 kV Short-circuit withstand strength Range PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-102:2018 | IEC 62271-102 :2018/AMD1 :2022 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 Scope of accreditation No. AB 324","parameters_zh":[{"name":"范围","range":"do 150 kA rms / 400 kA peak"}],"search_zh":"额定电压至 550 kV 的高压交流隔离开关与接地开关 Alternating current disconnectors 短路耐受强度 范围 PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-102:2018 | IEC 62271-102 :2018/AMD1 :2022 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 Scope of accreditation No. AB 324","methodology_zh":"短路耐受强度","test_object_zh":"额定电压至 550 kV 的高压交流隔离开关与接地开关 Alternating current disconnectors"},{"_id":"6a5dc9adf1c10c8ce825ac8c","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Odłączniki i uziemniki wysokonapięciowe prądu przemiennego o napięciu znamionowym do 550 kV, Alternating current disconnectors","test_object_en":"Alternating current disconnectors and earthing switches with rated voltage up to 550 kV","methodology":"Graniczne przyrosty temperatury","methodology_en":"Temperature-rise limits","parameters":[{"name":"Zakres","range":"do 20 kA"},{"name":"Próby nagrzewania prądem długotrwałym (odłączniki)"}],"parameters_en":[{"name":"Range","range":"do 20 kA"},{"name":"Temperature-rise tests with continuous current (disconnectors)"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Graniczne przyrosty temperatury\nZakres:\nZakres do 20 kA\nPróby nagrzewania prądem długotrwałym (odłączniki)","reference":"PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-102:2018 | IEC 62271-102 :2018/AMD1 :2022 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 Scope of accreditation No. AB 324","norm_bases":["PN-EN IEC 62271-102:2018-10","PN-EN IEC 62271-102:2018-10/A1:2023-01","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-102:2018","IEC 62271-102 :2018/AMD1 :2022","IEC 62271-1:2017","IEC 62271-1:2017/AMD1:2021 Scope of accreditation No. AB 324"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odłączniki i uziemniki wysokonapięciowe prądu przemiennego o napięciu znamionowym do 550 kV, Alternating current disconnectors Graniczne przyrosty temperatury\nZakres:\nZakres do 20 kA\nPróby nagrzewania prądem długotrwałym (odłączniki) PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-102:2018 | IEC 62271-102 :2018/AMD1 :2022 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 Scope of accreditation No. AB 324 Odlaczniki i uziemniki wysokonapieciowe pradu przemiennego o napieciu znamionowym do 550 kV, Alternating current disconnectors Graniczne przyrosty temperatury\nZakres:\nZakres do 20 kA\nProby nagrzewania pradem dlugotrwalym (odlaczniki) PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-102:2018 | IEC 62271-102 :2018/AMD1 :2022 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 Scope of accreditation No. AB 324","categories":["other"],"row_index":82,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Alternating current disconnectors and earthing switches with rated voltage up to 550 kV Temperature-rise limits Range Temperature-rise tests with continuous current (disconnectors) PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-102:2018 | IEC 62271-102 :2018/AMD1 :2022 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 Scope of accreditation No. AB 324","parameters_zh":[{"name":"范围","range":"do 20 kA"},{"name":"Próby nagrzewania prądem długotrwałym (odłączniki)"}],"search_zh":"额定电压至 550 kV 的高压交流隔离开关与接地开关 Alternating current disconnectors 温升限值 范围 PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-102:2018 | IEC 62271-102 :2018/AMD1 :2022 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 Scope of accreditation No. AB 324","methodology_zh":"温升限值","test_object_zh":"额定电压至 550 kV 的高压交流隔离开关与接地开关 Alternating current disconnectors"},{"_id":"6a5dc9adf1c10c8ce825ac8d","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Odłączniki i uziemniki wysokonapięciowe prądu przemiennego o napięciu znamionowym do 550 kV, Alternating current disconnectors","test_object_en":"Alternating current disconnectors and earthing switches with rated voltage up to 550 kV","methodology":"Rezystancja","methodology_en":"Resistance","parameters":[{"name":"Zakres od 10-5 Ω"},{"name":"Prąd probierczy","range":"do 200 A"},{"name":"Rezystancja toru głównego (odłączniki)"}],"parameters_en":[{"name":"Range from 10-5 Ω"},{"name":"Test current","range":"do 200 A"},{"name":"Resistance of the main circuit (disconnectors)"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Rezystancja\nZakres:\nZakres od 10-5 Ω\nPrąd probierczy do 200 A\nRezystancja toru głównego (odłączniki)","reference":"PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-102:2018 | IEC 62271-102 :2018/AMD1 :2022 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 Scope of accreditation No. AB 324","norm_bases":["PN-EN IEC 62271-102:2018-10","PN-EN IEC 62271-102:2018-10/A1:2023-01","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-102:2018","IEC 62271-102 :2018/AMD1 :2022","IEC 62271-1:2017","IEC 62271-1:2017/AMD1:2021 Scope of accreditation No. AB 324"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odłączniki i uziemniki wysokonapięciowe prądu przemiennego o napięciu znamionowym do 550 kV, Alternating current disconnectors Rezystancja\nZakres:\nZakres od 10-5 Ω\nPrąd probierczy do 200 A\nRezystancja toru głównego (odłączniki) PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-102:2018 | IEC 62271-102 :2018/AMD1 :2022 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 Scope of accreditation No. AB 324 Odlaczniki i uziemniki wysokonapieciowe pradu przemiennego o napieciu znamionowym do 550 kV, Alternating current disconnectors Rezystancja\nZakres:\nZakres od 10-5 Ω\nPrad probierczy do 200 A\nRezystancja toru glownego (odlaczniki) PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-102:2018 | IEC 62271-102 :2018/AMD1 :2022 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 Scope of accreditation No. AB 324","categories":["other"],"row_index":83,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Alternating current disconnectors and earthing switches with rated voltage up to 550 kV Resistance Range from 10-5 Ω Test current Resistance of the main circuit (disconnectors) PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-102:2018 | IEC 62271-102 :2018/AMD1 :2022 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 Scope of accreditation No. AB 324","methodology_zh":"电阻","search_zh":"额定电压至 550 kV 的高压交流隔离开关与接地开关 Alternating current disconnectors 电阻 范围自 10-5 Ω 起 试验电流 PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-102:2018 | IEC 62271-102 :2018/AMD1 :2022 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 Scope of accreditation No. AB 324","parameters_zh":[{"name":"范围自 10-5 Ω 起"},{"name":"试验电流","range":"do 200 A"},{"name":"Rezystancja toru głównego (odłączniki)"}],"test_object_zh":"额定电压至 550 kV 的高压交流隔离开关与接地开关 Alternating current disconnectors"},{"_id":"6a5dc9adf1c10c8ce825ac8e","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Odłączniki i uziemniki wysokonapięciowe prądu przemiennego o napięciu znamionowym do 550 kV, Alternating current disconnectors","test_object_en":"Alternating current disconnectors and earthing switches with rated voltage up to 550 kV","methodology":"Działanie mechaniczne, trwałość mechaniczna, Mechanical operation, Mechanical endurance","methodology_en":"Mechanical operation, mechanical endurance, Mechanical operation, Mechanical endurance","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Działanie mechaniczne, trwałość mechaniczna, Mechanical operation, Mechanical endurance","reference":"PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-102:2018 | IEC 62271-102 :2018/AMD1 :2022 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 Scope of accreditation No. AB 324","norm_bases":["PN-EN IEC 62271-102:2018-10","PN-EN IEC 62271-102:2018-10/A1:2023-01","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-102:2018","IEC 62271-102 :2018/AMD1 :2022","IEC 62271-1:2017","IEC 62271-1:2017/AMD1:2021 Scope of accreditation No. AB 324"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odłączniki i uziemniki wysokonapięciowe prądu przemiennego o napięciu znamionowym do 550 kV, Alternating current disconnectors Działanie mechaniczne, trwałość mechaniczna, Mechanical operation, Mechanical endurance PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-102:2018 | IEC 62271-102 :2018/AMD1 :2022 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 Scope of accreditation No. AB 324 Odlaczniki i uziemniki wysokonapieciowe pradu przemiennego o napieciu znamionowym do 550 kV, Alternating current disconnectors Dzialanie mechaniczne, trwalosc mechaniczna, Mechanical operation, Mechanical endurance PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-102:2018 | IEC 62271-102 :2018/AMD1 :2022 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 Scope of accreditation No. AB 324","categories":["other"],"row_index":84,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Alternating current disconnectors and earthing switches with rated voltage up to 550 kV Mechanical operation, mechanical endurance, Mechanical operation, Mechanical endurance PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-102:2018 | IEC 62271-102 :2018/AMD1 :2022 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 Scope of accreditation No. AB 324","search_zh":"额定电压至 550 kV 的高压交流隔离开关与接地开关 Alternating current disconnectors PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-102:2018 | IEC 62271-102 :2018/AMD1 :2022 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 Scope of accreditation No. AB 324","test_object_zh":"额定电压至 550 kV 的高压交流隔离开关与接地开关 Alternating current disconnectors"},{"_id":"6a5dc9adf1c10c8ce825ac8f","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Odłączniki i uziemniki wysokonapięciowe prądu przemiennego o napięciu znamionowym do 550 kV, Alternating current disconnectors","test_object_en":"Alternating current disconnectors and earthing switches with rated voltage up to 550 kV","methodology":"Zdolność łączenia","methodology_en":"Switching capability","parameters":[{"name":"Zakres","range":"do 4000 A"}],"parameters_en":[{"name":"Range","range":"do 4000 A"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Zdolność łączenia\nZakres do 4000 A","reference":"PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-102:2018 | IEC 62271-102 :2018/AMD1 :2022 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 Scope of accreditation No. AB 324","norm_bases":["PN-EN IEC 62271-102:2018-10","PN-EN IEC 62271-102:2018-10/A1:2023-01","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-102:2018","IEC 62271-102 :2018/AMD1 :2022","IEC 62271-1:2017","IEC 62271-1:2017/AMD1:2021 Scope of accreditation No. AB 324"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odłączniki i uziemniki wysokonapięciowe prądu przemiennego o napięciu znamionowym do 550 kV, Alternating current disconnectors Zdolność łączenia\nZakres do 4000 A PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-102:2018 | IEC 62271-102 :2018/AMD1 :2022 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 Scope of accreditation No. AB 324 Odlaczniki i uziemniki wysokonapieciowe pradu przemiennego o napieciu znamionowym do 550 kV, Alternating current disconnectors Zdolnosc laczenia\nZakres do 4000 A PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-102:2018 | IEC 62271-102 :2018/AMD1 :2022 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 Scope of accreditation No. AB 324","categories":["other"],"row_index":85,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Alternating current disconnectors and earthing switches with rated voltage up to 550 kV Switching capability Range PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-102:2018 | IEC 62271-102 :2018/AMD1 :2022 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 Scope of accreditation No. AB 324","parameters_zh":[{"name":"范围","range":"do 4000 A"}],"search_zh":"额定电压至 550 kV 的高压交流隔离开关与接地开关 Alternating current disconnectors 接通与分断能力 范围 PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-102:2018 | IEC 62271-102 :2018/AMD1 :2022 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 Scope of accreditation No. AB 324","methodology_zh":"接通与分断能力","test_object_zh":"额定电压至 550 kV 的高压交流隔离开关与接地开关 Alternating current disconnectors"},{"_id":"6a5dc9adf1c10c8ce825ac90","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Przekładniki prądowe do 145 kV, Current transformers","test_object_en":"Current transformers up to 145 kV","methodology":"Wytrzymałość mechaniczna","methodology_en":"Mechanical strength","parameters":[{"name":"Zakres","range":"do 5 kN"}],"parameters_en":[{"name":"Range","range":"do 5 kN"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość mechaniczna\nZakres do 5 kN","reference":"PN-EN 61869-1:2009 | PN-EN IEC 61869-1:2025-10 | IEC 61869-1:2007 | IEC 61869-1:2023 | PN-EN 61869-2:2013-06 | IEC 61869-2:2012","norm_bases":["PN-EN 61869-1:2009","PN-EN IEC 61869-1:2025-10","IEC 61869-1:2007","IEC 61869-1:2023","PN-EN 61869-2:2013-06","IEC 61869-2:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przekładniki prądowe do 145 kV, Current transformers Wytrzymałość mechaniczna\nZakres do 5 kN PN-EN 61869-1:2009 | PN-EN IEC 61869-1:2025-10 | IEC 61869-1:2007 | IEC 61869-1:2023 | PN-EN 61869-2:2013-06 | IEC 61869-2:2012 Przekladniki pradowe do 145 kV, Current transformers Wytrzymalosc mechaniczna\nZakres do 5 kN PN-EN 61869-1:2009 | PN-EN IEC 61869-1:2025-10 | IEC 61869-1:2007 | IEC 61869-1:2023 | PN-EN 61869-2:2013-06 | IEC 61869-2:2012","categories":["other"],"row_index":86,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Current transformers up to 145 kV Mechanical strength Range PN-EN 61869-1:2009 | PN-EN IEC 61869-1:2025-10 | IEC 61869-1:2007 | IEC 61869-1:2023 | PN-EN 61869-2:2013-06 | IEC 61869-2:2012","methodology_zh":"机械强度","parameters_zh":[{"name":"范围","range":"do 5 kN"}],"search_zh":"145 kV 及以下电流互感器 Current transformers 机械强度 范围 PN-EN 61869-1:2009 | PN-EN IEC 61869-1:2025-10 | IEC 61869-1:2007 | IEC 61869-1:2023 | PN-EN 61869-2:2013-06 | IEC 61869-2:2012","test_object_zh":"145 kV 及以下电流互感器 Current transformers"},{"_id":"6a5dc9adf1c10c8ce825ac91","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Przekładniki prądowe do 145 kV, Current transformers","test_object_en":"Current transformers up to 145 kV","methodology":"Wytrzymałość zwarciowa","methodology_en":"Short-circuit withstand strength","parameters":[{"name":"Zakres","range":"do 150 kA rms / 400 kA peak"}],"parameters_en":[{"name":"Range","range":"do 150 kA rms / 400 kA peak"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość zwarciowa\nZakres do 150 kA rms / 400 kA peak","reference":"PN-EN 61869-1:2009 | PN-EN IEC 61869-1:2025-10 | IEC 61869-1:2007 | IEC 61869-1:2023 | PN-EN 61869-2:2013-06 | IEC 61869-2:2012","norm_bases":["PN-EN 61869-1:2009","PN-EN IEC 61869-1:2025-10","IEC 61869-1:2007","IEC 61869-1:2023","PN-EN 61869-2:2013-06","IEC 61869-2:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przekładniki prądowe do 145 kV, Current transformers Wytrzymałość zwarciowa\nZakres do 150 kA rms / 400 kA peak PN-EN 61869-1:2009 | PN-EN IEC 61869-1:2025-10 | IEC 61869-1:2007 | IEC 61869-1:2023 | PN-EN 61869-2:2013-06 | IEC 61869-2:2012 Przekladniki pradowe do 145 kV, Current transformers Wytrzymalosc zwarciowa\nZakres do 150 kA rms / 400 kA peak PN-EN 61869-1:2009 | PN-EN IEC 61869-1:2025-10 | IEC 61869-1:2007 | IEC 61869-1:2023 | PN-EN 61869-2:2013-06 | IEC 61869-2:2012","categories":["other"],"row_index":87,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Current transformers up to 145 kV Short-circuit withstand strength Range PN-EN 61869-1:2009 | PN-EN IEC 61869-1:2025-10 | IEC 61869-1:2007 | IEC 61869-1:2023 | PN-EN 61869-2:2013-06 | IEC 61869-2:2012","parameters_zh":[{"name":"范围","range":"do 150 kA rms / 400 kA peak"}],"search_zh":"145 kV 及以下电流互感器 Current transformers 短路耐受强度 范围 PN-EN 61869-1:2009 | PN-EN IEC 61869-1:2025-10 | IEC 61869-1:2007 | IEC 61869-1:2023 | PN-EN 61869-2:2013-06 | IEC 61869-2:2012","methodology_zh":"短路耐受强度","test_object_zh":"145 kV 及以下电流互感器 Current transformers"},{"_id":"6a5dc9adf1c10c8ce825ac92","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Przekładniki prądowe do 145 kV, Current transformers","test_object_en":"Current transformers up to 145 kV","methodology":"Graniczne przyrosty temperatury","methodology_en":"Temperature-rise limits","parameters":[{"name":"Zakres","range":"do 20 kA"}],"parameters_en":[{"name":"Range","range":"do 20 kA"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Graniczne przyrosty temperatury\nZakres do 20 kA","reference":"PN-EN 61869-1:2009 | PN-EN IEC 61869-1:2025-10 | IEC 61869-1:2007 | IEC 61869-1:2023 | PN-EN 61869-2:2013-06 | IEC 61869-2:2012","norm_bases":["PN-EN 61869-1:2009","PN-EN IEC 61869-1:2025-10","IEC 61869-1:2007","IEC 61869-1:2023","PN-EN 61869-2:2013-06","IEC 61869-2:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przekładniki prądowe do 145 kV, Current transformers Graniczne przyrosty temperatury\nZakres do 20 kA PN-EN 61869-1:2009 | PN-EN IEC 61869-1:2025-10 | IEC 61869-1:2007 | IEC 61869-1:2023 | PN-EN 61869-2:2013-06 | IEC 61869-2:2012 Przekladniki pradowe do 145 kV, Current transformers Graniczne przyrosty temperatury\nZakres do 20 kA PN-EN 61869-1:2009 | PN-EN IEC 61869-1:2025-10 | IEC 61869-1:2007 | IEC 61869-1:2023 | PN-EN 61869-2:2013-06 | IEC 61869-2:2012","categories":["other"],"row_index":88,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Current transformers up to 145 kV Temperature-rise limits Range PN-EN 61869-1:2009 | PN-EN IEC 61869-1:2025-10 | IEC 61869-1:2007 | IEC 61869-1:2023 | PN-EN 61869-2:2013-06 | IEC 61869-2:2012","parameters_zh":[{"name":"范围","range":"do 20 kA"}],"search_zh":"145 kV 及以下电流互感器 Current transformers 温升限值 范围 PN-EN 61869-1:2009 | PN-EN IEC 61869-1:2025-10 | IEC 61869-1:2007 | IEC 61869-1:2023 | PN-EN 61869-2:2013-06 | IEC 61869-2:2012","methodology_zh":"温升限值","test_object_zh":"145 kV 及以下电流互感器 Current transformers"},{"_id":"6a5dc9adf1c10c8ce825ac93","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Przekładniki prądowe do 145 kV, Current transformers","test_object_en":"Current transformers up to 145 kV","methodology":"Sprawdzenie współczynnika bezpieczeństwa FS","methodology_en":"Verification of the safety factor FS","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Sprawdzenie współczynnika bezpieczeństwa FS","reference":"PN-EN 61869-1:2009 | PN-EN IEC 61869-1:2025-10 | IEC 61869-1:2007 | IEC 61869-1:2023 | PN-EN 61869-2:2013-06 | IEC 61869-2:2012","norm_bases":["PN-EN 61869-1:2009","PN-EN IEC 61869-1:2025-10","IEC 61869-1:2007","IEC 61869-1:2023","PN-EN 61869-2:2013-06","IEC 61869-2:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przekładniki prądowe do 145 kV, Current transformers Sprawdzenie współczynnika bezpieczeństwa FS PN-EN 61869-1:2009 | PN-EN IEC 61869-1:2025-10 | IEC 61869-1:2007 | IEC 61869-1:2023 | PN-EN 61869-2:2013-06 | IEC 61869-2:2012 Przekladniki pradowe do 145 kV, Current transformers Sprawdzenie wspolczynnika bezpieczenstwa FS PN-EN 61869-1:2009 | PN-EN IEC 61869-1:2025-10 | IEC 61869-1:2007 | IEC 61869-1:2023 | PN-EN 61869-2:2013-06 | IEC 61869-2:2012","categories":["other"],"row_index":89,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Current transformers up to 145 kV Verification of the safety factor FS PN-EN 61869-1:2009 | PN-EN IEC 61869-1:2025-10 | IEC 61869-1:2007 | IEC 61869-1:2023 | PN-EN 61869-2:2013-06 | IEC 61869-2:2012","search_zh":"145 kV 及以下电流互感器 Current transformers PN-EN 61869-1:2009 | PN-EN IEC 61869-1:2025-10 | IEC 61869-1:2007 | IEC 61869-1:2023 | PN-EN 61869-2:2013-06 | IEC 61869-2:2012","test_object_zh":"145 kV 及以下电流互感器 Current transformers"},{"_id":"6a5dc9adf1c10c8ce825ac94","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Przekładniki napięciowe do 145 kV, Inductive voltage transformers","test_object_en":"Inductive voltage transformers","methodology":"Wytrzymałość mechaniczna","methodology_en":"Mechanical strength","parameters":[{"name":"Zakres","range":"do 5 kN"}],"parameters_en":[{"name":"Range","range":"do 5 kN"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość mechaniczna\nZakres do 5 kN","reference":"PN-EN 61869-1:2009 | PN-EN IEC 61869-1:2025-10 | IEC 61869-1:2007 | IEC 61869-1:2023 | PN-EN 61869-3:2011 | IEC 61869-3:2011","norm_bases":["PN-EN 61869-1:2009","PN-EN IEC 61869-1:2025-10","IEC 61869-1:2007","IEC 61869-1:2023","PN-EN 61869-3:2011","IEC 61869-3:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przekładniki napięciowe do 145 kV, Inductive voltage transformers Wytrzymałość mechaniczna\nZakres do 5 kN PN-EN 61869-1:2009 | PN-EN IEC 61869-1:2025-10 | IEC 61869-1:2007 | IEC 61869-1:2023 | PN-EN 61869-3:2011 | IEC 61869-3:2011 Przekladniki napieciowe do 145 kV, Inductive voltage transformers Wytrzymalosc mechaniczna\nZakres do 5 kN PN-EN 61869-1:2009 | PN-EN IEC 61869-1:2025-10 | IEC 61869-1:2007 | IEC 61869-1:2023 | PN-EN 61869-3:2011 | IEC 61869-3:2011","categories":["other"],"row_index":90,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Inductive voltage transformers Mechanical strength Range PN-EN 61869-1:2009 | PN-EN IEC 61869-1:2025-10 | IEC 61869-1:2007 | IEC 61869-1:2023 | PN-EN 61869-3:2011 | IEC 61869-3:2011","methodology_zh":"机械强度","parameters_zh":[{"name":"范围","range":"do 5 kN"}],"search_zh":"机械强度 范围 PN-EN 61869-1:2009 | PN-EN IEC 61869-1:2025-10 | IEC 61869-1:2007 | IEC 61869-1:2023 | PN-EN 61869-3:2011 | IEC 61869-3:2011"},{"_id":"6a5dc9adf1c10c8ce825ac95","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Przekładniki napięciowe do 145 kV, Inductive voltage transformers","test_object_en":"Inductive voltage transformers","methodology":"Odporność na zwarcie","methodology_en":"Short-circuit withstand","parameters":[{"name":"Zakres","range":"do 145 kV"}],"parameters_en":[{"name":"Range","range":"do 145 kV"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na zwarcie\nZakres do 145 kV","reference":"PN-EN 61869-1:2009 | PN-EN IEC 61869-1:2025-10 | IEC 61869-1:2007 | IEC 61869-1:2023 | PN-EN 61869-3:2011 | IEC 61869-3:2011","norm_bases":["PN-EN 61869-1:2009","PN-EN IEC 61869-1:2025-10","IEC 61869-1:2007","IEC 61869-1:2023","PN-EN 61869-3:2011","IEC 61869-3:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przekładniki napięciowe do 145 kV, Inductive voltage transformers Odporność na zwarcie\nZakres do 145 kV PN-EN 61869-1:2009 | PN-EN IEC 61869-1:2025-10 | IEC 61869-1:2007 | IEC 61869-1:2023 | PN-EN 61869-3:2011 | IEC 61869-3:2011 Przekladniki napieciowe do 145 kV, Inductive voltage transformers Odpornosc na zwarcie\nZakres do 145 kV PN-EN 61869-1:2009 | PN-EN IEC 61869-1:2025-10 | IEC 61869-1:2007 | IEC 61869-1:2023 | PN-EN 61869-3:2011 | IEC 61869-3:2011","categories":["other"],"row_index":91,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Inductive voltage transformers Short-circuit withstand Range PN-EN 61869-1:2009 | PN-EN IEC 61869-1:2025-10 | IEC 61869-1:2007 | IEC 61869-1:2023 | PN-EN 61869-3:2011 | IEC 61869-3:2011","parameters_zh":[{"name":"范围","range":"do 145 kV"}],"search_zh":"范围 PN-EN 61869-1:2009 | PN-EN IEC 61869-1:2025-10 | IEC 61869-1:2007 | IEC 61869-1:2023 | PN-EN 61869-3:2011 | IEC 61869-3:2011"},{"_id":"6a5dc9adf1c10c8ce825ac96","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Przekładniki napięciowe do 145 kV, Inductive voltage transformers","test_object_en":"Inductive voltage transformers","methodology":"Graniczne przyrosty temperatury","methodology_en":"Temperature-rise limits","parameters":[{"name":"Zakres","range":"do 20 kA"}],"parameters_en":[{"name":"Range","range":"do 20 kA"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Graniczne przyrosty temperatury\nZakres do 20 kA","reference":"PN-EN 61869-1:2009 | PN-EN IEC 61869-1:2025-10 | IEC 61869-1:2007 | IEC 61869-1:2023 | PN-EN 61869-3:2011 | IEC 61869-3:2011","norm_bases":["PN-EN 61869-1:2009","PN-EN IEC 61869-1:2025-10","IEC 61869-1:2007","IEC 61869-1:2023","PN-EN 61869-3:2011","IEC 61869-3:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przekładniki napięciowe do 145 kV, Inductive voltage transformers Graniczne przyrosty temperatury\nZakres do 20 kA PN-EN 61869-1:2009 | PN-EN IEC 61869-1:2025-10 | IEC 61869-1:2007 | IEC 61869-1:2023 | PN-EN 61869-3:2011 | IEC 61869-3:2011 Przekladniki napieciowe do 145 kV, Inductive voltage transformers Graniczne przyrosty temperatury\nZakres do 20 kA PN-EN 61869-1:2009 | PN-EN IEC 61869-1:2025-10 | IEC 61869-1:2007 | IEC 61869-1:2023 | PN-EN 61869-3:2011 | IEC 61869-3:2011","categories":["other"],"row_index":92,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Inductive voltage transformers Temperature-rise limits Range PN-EN 61869-1:2009 | PN-EN IEC 61869-1:2025-10 | IEC 61869-1:2007 | IEC 61869-1:2023 | PN-EN 61869-3:2011 | IEC 61869-3:2011","parameters_zh":[{"name":"范围","range":"do 20 kA"}],"search_zh":"温升限值 范围 PN-EN 61869-1:2009 | PN-EN IEC 61869-1:2025-10 | IEC 61869-1:2007 | IEC 61869-1:2023 | PN-EN 61869-3:2011 | IEC 61869-3:2011","methodology_zh":"温升限值"},{"_id":"6a5dc9adf1c10c8ce825ac97","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Przekładniki kombinowane do 145 kV, Combined transformers","test_object_en":"Combined transformers up to 145 kV","methodology":"Wytrzymałość mechaniczna","methodology_en":"Mechanical strength","parameters":[{"name":"Zakres","range":"do 5 kN"}],"parameters_en":[{"name":"Range","range":"do 5 kN"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość mechaniczna\nZakres do 5 kN","reference":"PN-EN 61869-1:2009 | PN-EN IEC 61869-1:2025-10 | IEC 61869-1:2007 | IEC 61869-1:2023 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013","norm_bases":["PN-EN 61869-1:2009","PN-EN IEC 61869-1:2025-10","IEC 61869-1:2007","IEC 61869-1:2023","PN-EN 61869-4:2014-09","IEC 61869-4:2013"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przekładniki kombinowane do 145 kV, Combined transformers Wytrzymałość mechaniczna\nZakres do 5 kN PN-EN 61869-1:2009 | PN-EN IEC 61869-1:2025-10 | IEC 61869-1:2007 | IEC 61869-1:2023 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013 Przekladniki kombinowane do 145 kV, Combined transformers Wytrzymalosc mechaniczna\nZakres do 5 kN PN-EN 61869-1:2009 | PN-EN IEC 61869-1:2025-10 | IEC 61869-1:2007 | IEC 61869-1:2023 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013","categories":["other"],"row_index":93,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Combined transformers up to 145 kV Mechanical strength Range PN-EN 61869-1:2009 | PN-EN IEC 61869-1:2025-10 | IEC 61869-1:2007 | IEC 61869-1:2023 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013","methodology_zh":"机械强度","parameters_zh":[{"name":"范围","range":"do 5 kN"}],"search_zh":"145 kV 及以下组合式互感器 Combined transformers 机械强度 范围 PN-EN 61869-1:2009 | PN-EN IEC 61869-1:2025-10 | IEC 61869-1:2007 | IEC 61869-1:2023 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013","test_object_zh":"145 kV 及以下组合式互感器 Combined transformers"},{"_id":"6a5dc9adf1c10c8ce825ac98","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Przekładniki kombinowane do 145 kV, Combined transformers","test_object_en":"Combined transformers up to 145 kV","methodology":"Wytrzymałość zwarciowa","methodology_en":"Short-circuit withstand strength","parameters":[{"name":"Zakres","range":"do 150 kA rms / 400 kA peak"}],"parameters_en":[{"name":"Range","range":"do 150 kA rms / 400 kA peak"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość zwarciowa\nZakres do 150 kA rms / 400 kA peak","reference":"PN-EN 61869-2:2013 | IEC 61869-2:2012 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013 | PN-EN 61869-3:2011 | IEC 61869-3:2011 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013 Scope of accreditation No. AB 324","norm_bases":["PN-EN 61869-2:2013","IEC 61869-2:2012","PN-EN 61869-4:2014-09","IEC 61869-4:2013","PN-EN 61869-3:2011","IEC 61869-3:2011","PN-EN 61869-4:2014-09","IEC 61869-4:2013 Scope of accreditation No. AB 324"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przekładniki kombinowane do 145 kV, Combined transformers Wytrzymałość zwarciowa\nZakres do 150 kA rms / 400 kA peak PN-EN 61869-2:2013 | IEC 61869-2:2012 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013 | PN-EN 61869-3:2011 | IEC 61869-3:2011 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013 Scope of accreditation No. AB 324 Przekladniki kombinowane do 145 kV, Combined transformers Wytrzymalosc zwarciowa\nZakres do 150 kA rms / 400 kA peak PN-EN 61869-2:2013 | IEC 61869-2:2012 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013 | PN-EN 61869-3:2011 | IEC 61869-3:2011 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013 Scope of accreditation No. AB 324","categories":["other"],"row_index":94,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Combined transformers up to 145 kV Short-circuit withstand strength Range PN-EN 61869-2:2013 | IEC 61869-2:2012 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013 | PN-EN 61869-3:2011 | IEC 61869-3:2011 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013 Scope of accreditation No. AB 324","parameters_zh":[{"name":"范围","range":"do 150 kA rms / 400 kA peak"}],"search_zh":"145 kV 及以下组合式互感器 Combined transformers 短路耐受强度 范围 PN-EN 61869-2:2013 | IEC 61869-2:2012 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013 | PN-EN 61869-3:2011 | IEC 61869-3:2011 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013 Scope of accreditation No. AB 324","methodology_zh":"短路耐受强度","test_object_zh":"145 kV 及以下组合式互感器 Combined transformers"},{"_id":"6a5dc9adf1c10c8ce825ac99","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Przekładniki kombinowane do 145 kV, Combined transformers","test_object_en":"Combined transformers up to 145 kV","methodology":"Odporność na zwarcie","methodology_en":"Short-circuit withstand","parameters":[{"name":"Zakres","range":"do 145 kV"}],"parameters_en":[{"name":"Range","range":"do 145 kV"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na zwarcie\nZakres do 145 kV","reference":"PN-EN 61869-2:2013 | IEC 61869-2:2012 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013 | PN-EN 61869-3:2011 | IEC 61869-3:2011 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013 Scope of accreditation No. AB 324","norm_bases":["PN-EN 61869-2:2013","IEC 61869-2:2012","PN-EN 61869-4:2014-09","IEC 61869-4:2013","PN-EN 61869-3:2011","IEC 61869-3:2011","PN-EN 61869-4:2014-09","IEC 61869-4:2013 Scope of accreditation No. AB 324"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przekładniki kombinowane do 145 kV, Combined transformers Odporność na zwarcie\nZakres do 145 kV PN-EN 61869-2:2013 | IEC 61869-2:2012 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013 | PN-EN 61869-3:2011 | IEC 61869-3:2011 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013 Scope of accreditation No. AB 324 Przekladniki kombinowane do 145 kV, Combined transformers Odpornosc na zwarcie\nZakres do 145 kV PN-EN 61869-2:2013 | IEC 61869-2:2012 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013 | PN-EN 61869-3:2011 | IEC 61869-3:2011 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013 Scope of accreditation No. AB 324","categories":["other"],"row_index":95,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Combined transformers up to 145 kV Short-circuit withstand Range PN-EN 61869-2:2013 | IEC 61869-2:2012 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013 | PN-EN 61869-3:2011 | IEC 61869-3:2011 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013 Scope of accreditation No. AB 324","parameters_zh":[{"name":"范围","range":"do 145 kV"}],"search_zh":"145 kV 及以下组合式互感器 Combined transformers 范围 PN-EN 61869-2:2013 | IEC 61869-2:2012 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013 | PN-EN 61869-3:2011 | IEC 61869-3:2011 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013 Scope of accreditation No. AB 324","test_object_zh":"145 kV 及以下组合式互感器 Combined transformers"},{"_id":"6a5dc9adf1c10c8ce825ac9a","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Przekładniki kombinowane do 145 kV, Combined transformers","test_object_en":"Combined transformers up to 145 kV","methodology":"Graniczne przyrosty temperatury","methodology_en":"Temperature-rise limits","parameters":[{"name":"Zakres","range":"do 20 kA"}],"parameters_en":[{"name":"Range","range":"do 20 kA"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Graniczne przyrosty temperatury\nZakres do 20 kA","reference":"PN-EN 61869-2:2013 | IEC 61869-2:2012 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013 | PN-EN 61869-3:2011 | IEC 61869-3:2011 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013 Scope of accreditation No. AB 324","norm_bases":["PN-EN 61869-2:2013","IEC 61869-2:2012","PN-EN 61869-4:2014-09","IEC 61869-4:2013","PN-EN 61869-3:2011","IEC 61869-3:2011","PN-EN 61869-4:2014-09","IEC 61869-4:2013 Scope of accreditation No. AB 324"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przekładniki kombinowane do 145 kV, Combined transformers Graniczne przyrosty temperatury\nZakres do 20 kA PN-EN 61869-2:2013 | IEC 61869-2:2012 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013 | PN-EN 61869-3:2011 | IEC 61869-3:2011 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013 Scope of accreditation No. AB 324 Przekladniki kombinowane do 145 kV, Combined transformers Graniczne przyrosty temperatury\nZakres do 20 kA PN-EN 61869-2:2013 | IEC 61869-2:2012 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013 | PN-EN 61869-3:2011 | IEC 61869-3:2011 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013 Scope of accreditation No. AB 324","categories":["other"],"row_index":96,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Combined transformers up to 145 kV Temperature-rise limits Range PN-EN 61869-2:2013 | IEC 61869-2:2012 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013 | PN-EN 61869-3:2011 | IEC 61869-3:2011 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013 Scope of accreditation No. AB 324","parameters_zh":[{"name":"范围","range":"do 20 kA"}],"search_zh":"145 kV 及以下组合式互感器 Combined transformers 温升限值 范围 PN-EN 61869-2:2013 | IEC 61869-2:2012 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013 | PN-EN 61869-3:2011 | IEC 61869-3:2011 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013 Scope of accreditation No. AB 324","methodology_zh":"温升限值","test_object_zh":"145 kV 及以下组合式互感器 Combined transformers"},{"_id":"6a5dc9adf1c10c8ce825ac9b","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Przekładniki kombinowane do 145 kV, Combined transformers","test_object_en":"Combined transformers up to 145 kV","methodology":"Sprawdzenie współczynnika bezpieczeństwa FS","methodology_en":"Verification of the safety factor FS","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Sprawdzenie współczynnika bezpieczeństwa FS","reference":"PN-EN 61869-2:2013 | IEC 61869-2:2012 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013 | PN-EN 61869-3:2011 | IEC 61869-3:2011 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013 Scope of accreditation No. AB 324","norm_bases":["PN-EN 61869-2:2013","IEC 61869-2:2012","PN-EN 61869-4:2014-09","IEC 61869-4:2013","PN-EN 61869-3:2011","IEC 61869-3:2011","PN-EN 61869-4:2014-09","IEC 61869-4:2013 Scope of accreditation No. AB 324"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przekładniki kombinowane do 145 kV, Combined transformers Sprawdzenie współczynnika bezpieczeństwa FS PN-EN 61869-2:2013 | IEC 61869-2:2012 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013 | PN-EN 61869-3:2011 | IEC 61869-3:2011 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013 Scope of accreditation No. AB 324 Przekladniki kombinowane do 145 kV, Combined transformers Sprawdzenie wspolczynnika bezpieczenstwa FS PN-EN 61869-2:2013 | IEC 61869-2:2012 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013 | PN-EN 61869-3:2011 | IEC 61869-3:2011 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013 Scope of accreditation No. AB 324","categories":["other"],"row_index":97,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Combined transformers up to 145 kV Verification of the safety factor FS PN-EN 61869-2:2013 | IEC 61869-2:2012 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013 | PN-EN 61869-3:2011 | IEC 61869-3:2011 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013 Scope of accreditation No. AB 324","search_zh":"145 kV 及以下组合式互感器 Combined transformers PN-EN 61869-2:2013 | IEC 61869-2:2012 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013 | PN-EN 61869-3:2011 | IEC 61869-3:2011 | PN-EN 61869-4:2014-09 | IEC 61869-4:2013 Scope of accreditation No. AB 324","test_object_zh":"145 kV 及以下组合式互感器 Combined transformers"},{"_id":"6a5dc9adf1c10c8ce825ac9c","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Uziemniki wysokonapięciowe o napięciu znamionowym do 36 kV, Alternating current earthing","test_object_en":"High-voltage earthing switches with a rated voltage up to 36 kV","methodology":"Zdolność załączania na zwarcie","methodology_en":"Short-circuit making capacity","parameters":[{"name":"Zakres","range":"do 100 kA wartości szczytowej"},{"name":"Short-circuit making capacity"}],"parameters_en":[{"name":"Range","range":"do 100 kA wartości szczytowej"},{"name":"Short-circuit making capacity"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Zdolność załączania na zwarcie\nZakres:\nZakres do 100 kA wartości szczytowej\nShort-circuit making capacity","reference":"PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | IEC 62271-102:2018 | IEC 62271-102:2018/AMD1:2022","norm_bases":["PN-EN IEC 62271-102:2018-10","PN-EN IEC 62271-102:2018-10/A1:2023-01","IEC 62271-102:2018","IEC 62271-102:2018/AMD1:2022"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Uziemniki wysokonapięciowe o napięciu znamionowym do 36 kV, Alternating current earthing Zdolność załączania na zwarcie\nZakres:\nZakres do 100 kA wartości szczytowej\nShort-circuit making capacity PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | IEC 62271-102:2018 | IEC 62271-102:2018/AMD1:2022 Uziemniki wysokonapieciowe o napieciu znamionowym do 36 kV, Alternating current earthing Zdolnosc zalaczania na zwarcie\nZakres:\nZakres do 100 kA wartosci szczytowej\nShort-circuit making capacity PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | IEC 62271-102:2018 | IEC 62271-102:2018/AMD1:2022","categories":["other"],"row_index":98,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"High-voltage earthing switches with a rated voltage up to 36 kV Short-circuit making capacity Range Short-circuit making capacity PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | IEC 62271-102:2018 | IEC 62271-102:2018/AMD1:2022","parameters_zh":[{"name":"范围","range":"do 100 kA wartości szczytowej"},{"name":"Short-circuit making capacity"}],"search_zh":"范围 PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | IEC 62271-102:2018 | IEC 62271-102:2018/AMD1:2022"},{"_id":"6a5dc9adf1c10c8ce825ac9d","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Uziemniki wysokonapięciowe prądu przemiennego o napięciu znamionowym do 550 kV, Alternating current earthing","test_object_en":"High-voltage alternating current earthing switches with a rated voltage up to 550 kV","methodology":"Zdolność łączenia","methodology_en":"Switching capability","parameters":[{"name":"Zakres","range":"do 200 A"}],"parameters_en":[{"name":"Range","range":"do 200 A"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Zdolność łączenia\nZakres do 200 A","reference":"PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | IEC 62271-102:2018 | IEC 62271-102:2018/AMD1:2022","norm_bases":["PN-EN IEC 62271-102:2018-10","PN-EN IEC 62271-102:2018-10/A1:2023-01","IEC 62271-102:2018","IEC 62271-102:2018/AMD1:2022"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Uziemniki wysokonapięciowe prądu przemiennego o napięciu znamionowym do 550 kV, Alternating current earthing Zdolność łączenia\nZakres do 200 A PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | IEC 62271-102:2018 | IEC 62271-102:2018/AMD1:2022 Uziemniki wysokonapieciowe pradu przemiennego o napieciu znamionowym do 550 kV, Alternating current earthing Zdolnosc laczenia\nZakres do 200 A PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | IEC 62271-102:2018 | IEC 62271-102:2018/AMD1:2022","categories":["other"],"row_index":99,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"High-voltage alternating current earthing switches with a rated voltage up to 550 kV Switching capability Range PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | IEC 62271-102:2018 | IEC 62271-102:2018/AMD1:2022","parameters_zh":[{"name":"范围","range":"do 200 A"}],"search_zh":"接通与分断能力 范围 PN-EN IEC 62271-102:2018-10 | PN-EN IEC 62271-102:2018-10/A1:2023-01 | IEC 62271-102:2018 | IEC 62271-102:2018/AMD1:2022","methodology_zh":"接通与分断能力"},{"_id":"6a5dc9adf1c10c8ce825ac9e","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Bezpieczniki topikowe wysoko -napięciowe ograniczające prądu przemiennego o napięciu znamionowym do 36 kV","test_object_en":"High-voltage current-limiting fuses for alternating current with rated voltage up to 36 kV","methodology":"Zdolność łączenia","methodology_en":"Switching capability","parameters":[{"name":"Zakres","range":"do 63 kA"},{"name":"Breaking capacity"}],"parameters_en":[{"name":"Range","range":"do 63 kA"},{"name":"Breaking capacity"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Zdolność łączenia\nZakres:\nZakres do 63 kA\nBreaking capacity","reference":"PN-EN IEC 60282-1:2021-01 | IEC 60282-1:2020 IEEE Std C37.41-2016","norm_bases":["PN-EN IEC 60282-1:2021-01","IEC 60282-1:2020 IEEE Std C37.41-2016"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Bezpieczniki topikowe wysoko -napięciowe ograniczające prądu przemiennego o napięciu znamionowym do 36 kV Zdolność łączenia\nZakres:\nZakres do 63 kA\nBreaking capacity PN-EN IEC 60282-1:2021-01 | IEC 60282-1:2020 IEEE Std C37.41-2016 Bezpieczniki topikowe wysoko -napieciowe ograniczajace pradu przemiennego o napieciu znamionowym do 36 kV Zdolnosc laczenia\nZakres:\nZakres do 63 kA\nBreaking capacity PN-EN IEC 60282-1:2021-01 | IEC 60282-1:2020 IEEE Std C37.41-2016","categories":["other"],"row_index":100,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"High-voltage current-limiting fuses for alternating current with rated voltage up to 36 kV Switching capability Range Breaking capacity PN-EN IEC 60282-1:2021-01 | IEC 60282-1:2020 IEEE Std C37.41-2016","parameters_zh":[{"name":"范围","range":"do 63 kA"},{"name":"Breaking capacity"}],"search_zh":"接通与分断能力 范围 PN-EN IEC 60282-1:2021-01 | IEC 60282-1:2020 IEEE Std C37.41-2016","methodology_zh":"接通与分断能力"},{"_id":"6a5dc9adf1c10c8ce825ac9f","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Bezpieczniki topikowe wysoko -napięciowe ograniczające prądu przemiennego o napięciu znamionowym do 36 kV","test_object_en":"High-voltage current-limiting fuses for alternating current with rated voltage up to 36 kV","methodology":"Charakterystyki czasowo-prądowe","methodology_en":"Time-current characteristics","parameters":[{"name":"Zakres","range":"do 25 kA"},{"name":"Time-current characteristics"}],"parameters_en":[{"name":"Range","range":"do 25 kA"},{"name":"Time-current characteristics"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Charakterystyki czasowo-prądowe\nZakres:\nZakres do 25 kA\nTime-current characteristics","reference":"PN-EN IEC 60282-1:2021-01 | IEC 60282-1:2020 IEEE Std C37.41-2016","norm_bases":["PN-EN IEC 60282-1:2021-01","IEC 60282-1:2020 IEEE Std C37.41-2016"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Bezpieczniki topikowe wysoko -napięciowe ograniczające prądu przemiennego o napięciu znamionowym do 36 kV Charakterystyki czasowo-prądowe\nZakres:\nZakres do 25 kA\nTime-current characteristics PN-EN IEC 60282-1:2021-01 | IEC 60282-1:2020 IEEE Std C37.41-2016 Bezpieczniki topikowe wysoko -napieciowe ograniczajace pradu przemiennego o napieciu znamionowym do 36 kV Charakterystyki czasowo-pradowe\nZakres:\nZakres do 25 kA\nTime-current characteristics PN-EN IEC 60282-1:2021-01 | IEC 60282-1:2020 IEEE Std C37.41-2016","categories":["other"],"row_index":101,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"High-voltage current-limiting fuses for alternating current with rated voltage up to 36 kV Time-current characteristics Range Time-current characteristics PN-EN IEC 60282-1:2021-01 | IEC 60282-1:2020 IEEE Std C37.41-2016","parameters_zh":[{"name":"范围","range":"do 25 kA"},{"name":"Time-current characteristics"}],"search_zh":"范围 PN-EN IEC 60282-1:2021-01 | IEC 60282-1:2020 IEEE Std C37.41-2016"},{"_id":"6a5dc9adf1c10c8ce825aca0","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Bezpieczniki topikowe wysoko -napięciowe ograniczające prądu przemiennego o napięciu znamionowym do 36 kV","test_object_en":"High-voltage current-limiting fuses for alternating current with rated voltage up to 36 kV","methodology":"Graniczne przyrosty temperatury","methodology_en":"Temperature-rise limits","parameters":[{"name":"Zakres","range":"do 20 kA"},{"name":"Pomiar strat mocy"}],"parameters_en":[{"name":"Range","range":"do 20 kA"},{"name":"Measurement of power losses"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Graniczne przyrosty temperatury\nZakres:\nZakres do 20 kA\nPomiar strat mocy","reference":"PN-EN IEC 60282-1:2021-01 | IEC 60282-1:2020 IEEE Std C37.41-2016","norm_bases":["PN-EN IEC 60282-1:2021-01","IEC 60282-1:2020 IEEE Std C37.41-2016"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Bezpieczniki topikowe wysoko -napięciowe ograniczające prądu przemiennego o napięciu znamionowym do 36 kV Graniczne przyrosty temperatury\nZakres:\nZakres do 20 kA\nPomiar strat mocy PN-EN IEC 60282-1:2021-01 | IEC 60282-1:2020 IEEE Std C37.41-2016 Bezpieczniki topikowe wysoko -napieciowe ograniczajace pradu przemiennego o napieciu znamionowym do 36 kV Graniczne przyrosty temperatury\nZakres:\nZakres do 20 kA\nPomiar strat mocy PN-EN IEC 60282-1:2021-01 | IEC 60282-1:2020 IEEE Std C37.41-2016","categories":["other"],"row_index":102,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"High-voltage current-limiting fuses for alternating current with rated voltage up to 36 kV Temperature-rise limits Range Measurement of power losses PN-EN IEC 60282-1:2021-01 | IEC 60282-1:2020 IEEE Std C37.41-2016","parameters_zh":[{"name":"范围","range":"do 20 kA"},{"name":"Pomiar strat mocy"}],"search_zh":"温升限值 范围 PN-EN IEC 60282-1:2021-01 | IEC 60282-1:2020 IEEE Std C37.41-2016","methodology_zh":"温升限值"},{"_id":"6a5dc9adf1c10c8ce825aca1","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Bezpieczniki wydmuchowe o napięciu znamionowym do 36 kV","test_object_en":"Expulsion fuses with rated voltage up to 36 kV","methodology":"Zdolność łączenia","methodology_en":"Switching capability","parameters":[{"name":"Zakres","range":"do 63 kA"},{"name":"Breaking capacity"}],"parameters_en":[{"name":"Range","range":"do 63 kA"},{"name":"Breaking capacity"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Zdolność łączenia\nZakres:\nZakres do 63 kA\nBreaking capacity","reference":"IEC 60282-2:2008 Scope of accreditation No. AB 324","norm_bases":["IEC 60282-2:2008 Scope of accreditation No. AB 324"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Bezpieczniki wydmuchowe o napięciu znamionowym do 36 kV Zdolność łączenia\nZakres:\nZakres do 63 kA\nBreaking capacity IEC 60282-2:2008 Scope of accreditation No. AB 324 Bezpieczniki wydmuchowe o napieciu znamionowym do 36 kV Zdolnosc laczenia\nZakres:\nZakres do 63 kA\nBreaking capacity IEC 60282-2:2008 Scope of accreditation No. AB 324","categories":["other"],"row_index":103,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Expulsion fuses with rated voltage up to 36 kV Switching capability Range Breaking capacity IEC 60282-2:2008 Scope of accreditation No. AB 324","parameters_zh":[{"name":"范围","range":"do 63 kA"},{"name":"Breaking capacity"}],"search_zh":"接通与分断能力 范围 IEC 60282-2:2008 Scope of accreditation No. AB 324","methodology_zh":"接通与分断能力"},{"_id":"6a5dc9adf1c10c8ce825aca2","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Bezpieczniki wydmuchowe o napięciu znamionowym do 36 kV","test_object_en":"Expulsion fuses with rated voltage up to 36 kV","methodology":"Graniczne przyrosty temperatury","methodology_en":"Temperature-rise limits","parameters":[{"name":"Zakres","range":"do 20 kA"}],"parameters_en":[{"name":"Range","range":"do 20 kA"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Graniczne przyrosty temperatury\nZakres do 20 kA","reference":"IEC 60282-2:2008 Scope of accreditation No. AB 324","norm_bases":["IEC 60282-2:2008 Scope of accreditation No. AB 324"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Bezpieczniki wydmuchowe o napięciu znamionowym do 36 kV Graniczne przyrosty temperatury\nZakres do 20 kA IEC 60282-2:2008 Scope of accreditation No. AB 324 Bezpieczniki wydmuchowe o napieciu znamionowym do 36 kV Graniczne przyrosty temperatury\nZakres do 20 kA IEC 60282-2:2008 Scope of accreditation No. AB 324","categories":["other"],"row_index":104,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Expulsion fuses with rated voltage up to 36 kV Temperature-rise limits Range IEC 60282-2:2008 Scope of accreditation No. AB 324","parameters_zh":[{"name":"范围","range":"do 20 kA"}],"search_zh":"温升限值 范围 IEC 60282-2:2008 Scope of accreditation No. AB 324","methodology_zh":"温升限值"},{"_id":"6a5dc9adf1c10c8ce825aca3","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Bezpieczniki wydmuchowe o napięciu znamionowym do 36 kV","test_object_en":"Expulsion fuses with rated voltage up to 36 kV","methodology":"Prawidłowość działania mechanicznego","methodology_en":"Correctness of mechanical operation","parameters":[{"name":"Zakres","range":"do 15 kN"}],"parameters_en":[{"name":"Range","range":"do 15 kN"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Prawidłowość działania mechanicznego\nZakres do 15 kN","reference":"IEC 60282-2:2008 Scope of accreditation No. AB 324","norm_bases":["IEC 60282-2:2008 Scope of accreditation No. AB 324"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Bezpieczniki wydmuchowe o napięciu znamionowym do 36 kV Prawidłowość działania mechanicznego\nZakres do 15 kN IEC 60282-2:2008 Scope of accreditation No. AB 324 Bezpieczniki wydmuchowe o napieciu znamionowym do 36 kV Prawidlowosc dzialania mechanicznego\nZakres do 15 kN IEC 60282-2:2008 Scope of accreditation No. AB 324","categories":["other"],"row_index":105,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Expulsion fuses with rated voltage up to 36 kV Correctness of mechanical operation Range IEC 60282-2:2008 Scope of accreditation No. AB 324","parameters_zh":[{"name":"范围","range":"do 15 kN"}],"search_zh":"机械动作的正确性 范围 IEC 60282-2:2008 Scope of accreditation No. AB 324","methodology_zh":"机械动作的正确性"},{"_id":"6a5dc9adf1c10c8ce825aca4","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Łańcuchy izolatorów do 420 kV, Insulators strings","test_object_en":"Insulator strings up to 420 kV","methodology":"Odporność na działanie łuku elektrycznego","methodology_en":"Resistance to electric arc","parameters":[{"name":"Zakres","range":"do 40 kA"}],"parameters_en":[{"name":"Range","range":"do 40 kA"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na działanie łuku elektrycznego\nZakres do 40 kA","reference":"PN-EN 61467:2012 | IEC 61467:2008","norm_bases":["PN-EN 61467:2012","IEC 61467:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Łańcuchy izolatorów do 420 kV, Insulators strings Odporność na działanie łuku elektrycznego\nZakres do 40 kA PN-EN 61467:2012 | IEC 61467:2008 Lancuchy izolatorow do 420 kV, Insulators strings Odpornosc na dzialanie luku elektrycznego\nZakres do 40 kA PN-EN 61467:2012 | IEC 61467:2008","categories":["other"],"row_index":106,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Insulator strings up to 420 kV Resistance to electric arc Range PN-EN 61467:2012 | IEC 61467:2008","parameters_zh":[{"name":"范围","range":"do 40 kA"}],"search_zh":"耐电弧作用性 范围 PN-EN 61467:2012 | IEC 61467:2008","methodology_zh":"耐电弧作用性"},{"_id":"6a5dc9adf1c10c8ce825aca5","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Przenośny sprzęt do uziemiania lub uziemiania i zwierania","test_object_en":"Portable equipment for earthing or earthing and short-circuiting","methodology":"Wytrzymałość zwarciowa","methodology_en":"Short-circuit withstand strength","parameters":[{"name":"Zakres","range":"do 150 kA rms / 400 kA peak"}],"parameters_en":[{"name":"Range","range":"do 150 kA rms / 400 kA peak"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość zwarciowa\nZakres do 150 kA rms / 400 kA peak","reference":"PN-EN 61230:2011 | IEC 61230:2008","norm_bases":["PN-EN 61230:2011","IEC 61230:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przenośny sprzęt do uziemiania lub uziemiania i zwierania Wytrzymałość zwarciowa\nZakres do 150 kA rms / 400 kA peak PN-EN 61230:2011 | IEC 61230:2008 Przenosny sprzet do uziemiania lub uziemiania i zwierania Wytrzymalosc zwarciowa\nZakres do 150 kA rms / 400 kA peak PN-EN 61230:2011 | IEC 61230:2008","categories":["other"],"row_index":107,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Portable equipment for earthing or earthing and short-circuiting Short-circuit withstand strength Range PN-EN 61230:2011 | IEC 61230:2008","parameters_zh":[{"name":"范围","range":"do 150 kA rms / 400 kA peak"}],"search_zh":"便携式接地或接地短路装置 短路耐受强度 范围 PN-EN 61230:2011 | IEC 61230:2008","methodology_zh":"短路耐受强度","test_object_zh":"便携式接地或接地短路装置"},{"_id":"6a5dc9adf1c10c8ce825aca6","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Przenośny sprzęt do uziemiania lub uziemiania i zwierania","test_object_en":"Portable equipment for earthing or earthing and short-circuiting","methodology":"Wytrzymałość mechaniczna","methodology_en":"Mechanical strength","parameters":[{"name":"Zakres","range":"do 15 kN"},{"name":"Próby skręcania i zginania przewodu z końcówkami Próby rozciągania"}],"parameters_en":[{"name":"Range","range":"do 15 kN"},{"name":"Torsion and bending tests of the cable with terminations Tensile tests"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość mechaniczna\nZakres:\nZakres do 15 kN\nPróby skręcania i zginania przewodu z końcówkami Próby rozciągania","reference":"PN-EN 61230:2011 | IEC 61230:2008","norm_bases":["PN-EN 61230:2011","IEC 61230:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przenośny sprzęt do uziemiania lub uziemiania i zwierania Wytrzymałość mechaniczna\nZakres:\nZakres do 15 kN\nPróby skręcania i zginania przewodu z końcówkami Próby rozciągania PN-EN 61230:2011 | IEC 61230:2008 Przenosny sprzet do uziemiania lub uziemiania i zwierania Wytrzymalosc mechaniczna\nZakres:\nZakres do 15 kN\nProby skrecania i zginania przewodu z koncowkami Proby rozciagania PN-EN 61230:2011 | IEC 61230:2008","categories":["other"],"row_index":108,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Portable equipment for earthing or earthing and short-circuiting Mechanical strength Range Torsion and bending tests of the cable with terminations Tensile tests PN-EN 61230:2011 | IEC 61230:2008","methodology_zh":"机械强度","parameters_zh":[{"name":"范围","range":"do 15 kN"},{"name":"Próby skręcania i zginania przewodu z końcówkami Próby rozciągania"}],"search_zh":"便携式接地或接地短路装置 机械强度 范围 PN-EN 61230:2011 | IEC 61230:2008","test_object_zh":"便携式接地或接地短路装置"},{"_id":"6a5dc9adf1c10c8ce825aca7","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Przenośny sprzęt do uziemiania lub uziemiania i zwierania","test_object_en":"Portable equipment for earthing or earthing and short-circuiting","methodology":"Wytrzymałość na zmęczenie i penetrację wilgoci","methodology_en":"Resistance to fatigue and moisture penetration","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na zmęczenie i penetrację wilgoci","reference":"PN-EN 61230:2011 | IEC 61230:2008","norm_bases":["PN-EN 61230:2011","IEC 61230:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przenośny sprzęt do uziemiania lub uziemiania i zwierania Wytrzymałość na zmęczenie i penetrację wilgoci PN-EN 61230:2011 | IEC 61230:2008 Przenosny sprzet do uziemiania lub uziemiania i zwierania Wytrzymalosc na zmeczenie i penetracje wilgoci PN-EN 61230:2011 | IEC 61230:2008","categories":["other"],"row_index":109,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Portable equipment for earthing or earthing and short-circuiting Resistance to fatigue and moisture penetration PN-EN 61230:2011 | IEC 61230:2008","search_zh":"便携式接地或接地短路装置 PN-EN 61230:2011 | IEC 61230:2008","test_object_zh":"便携式接地或接地短路装置"},{"_id":"6a5dc9adf1c10c8ce825aca8","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Przenośny sprzęt do uziemiania lub uziemiania i zwierania","test_object_en":"Portable equipment for earthing or earthing and short-circuiting","methodology":"Trwałość znakowania","methodology_en":"Durability of marking","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Trwałość znakowania","reference":"PN-EN 61230:2011 | IEC 61230:2008","norm_bases":["PN-EN 61230:2011","IEC 61230:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przenośny sprzęt do uziemiania lub uziemiania i zwierania Trwałość znakowania PN-EN 61230:2011 | IEC 61230:2008 Przenosny sprzet do uziemiania lub uziemiania i zwierania Trwalosc znakowania PN-EN 61230:2011 | IEC 61230:2008","categories":["other"],"row_index":110,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Portable equipment for earthing or earthing and short-circuiting Durability of marking PN-EN 61230:2011 | IEC 61230:2008","methodology_zh":"标识耐久性","search_zh":"便携式接地或接地短路装置 标识耐久性 PN-EN 61230:2011 | IEC 61230:2008","test_object_zh":"便携式接地或接地短路装置"},{"_id":"6a5dc9adf1c10c8ce825aca9","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Reklozery do układów prądu przemiennego o napięciu do 38 kV","test_object_en":"Reclosers for alternating current systems with voltage up to 38 kV","methodology":"Wytrzymałość zwarciowa","methodology_en":"Short-circuit withstand strength","parameters":[{"name":"Zakres","range":"do 150 kA rms / 400 kA peak"}],"parameters_en":[{"name":"Range","range":"do 150 kA rms / 400 kA peak"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość zwarciowa\nZakres do 150 kA rms / 400 kA peak","reference":"IEC 62271-111:2019 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 Scope of accreditation No. AB 324","norm_bases":["IEC 62271-111:2019","IEC 62271-1:2017","IEC 62271-1:2017/AMD1:2021","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06 Scope of accreditation No. AB 324"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Reklozery do układów prądu przemiennego o napięciu do 38 kV Wytrzymałość zwarciowa\nZakres do 150 kA rms / 400 kA peak IEC 62271-111:2019 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 Scope of accreditation No. AB 324 Reklozery do ukladow pradu przemiennego o napieciu do 38 kV Wytrzymalosc zwarciowa\nZakres do 150 kA rms / 400 kA peak IEC 62271-111:2019 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 Scope of accreditation No. AB 324","categories":["other"],"row_index":111,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Reclosers for alternating current systems with voltage up to 38 kV Short-circuit withstand strength Range IEC 62271-111:2019 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 Scope of accreditation No. AB 324","parameters_zh":[{"name":"范围","range":"do 150 kA rms / 400 kA peak"}],"search_zh":"短路耐受强度 范围 IEC 62271-111:2019 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 Scope of accreditation No. AB 324","methodology_zh":"短路耐受强度"},{"_id":"6a5dc9adf1c10c8ce825acaa","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Reklozery do układów prądu przemiennego o napięciu do 38 kV","test_object_en":"Reclosers for alternating current systems with voltage up to 38 kV","methodology":"Graniczne przyrosty temperatury","methodology_en":"Temperature-rise limits","parameters":[{"name":"Zakres","range":"do 20 kA"},{"name":"Próby nagrzewania prądem długotrwałym"}],"parameters_en":[{"name":"Range","range":"do 20 kA"},{"name":"Temperature-rise tests with continuous current"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Graniczne przyrosty temperatury\nZakres:\nZakres do 20 kA\nPróby nagrzewania prądem długotrwałym","reference":"IEC 62271-111:2019 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 Scope of accreditation No. AB 324","norm_bases":["IEC 62271-111:2019","IEC 62271-1:2017","IEC 62271-1:2017/AMD1:2021","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06 Scope of accreditation No. AB 324"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Reklozery do układów prądu przemiennego o napięciu do 38 kV Graniczne przyrosty temperatury\nZakres:\nZakres do 20 kA\nPróby nagrzewania prądem długotrwałym IEC 62271-111:2019 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 Scope of accreditation No. AB 324 Reklozery do ukladow pradu przemiennego o napieciu do 38 kV Graniczne przyrosty temperatury\nZakres:\nZakres do 20 kA\nProby nagrzewania pradem dlugotrwalym IEC 62271-111:2019 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 Scope of accreditation No. AB 324","categories":["other"],"row_index":112,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Reclosers for alternating current systems with voltage up to 38 kV Temperature-rise limits Range Temperature-rise tests with continuous current IEC 62271-111:2019 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 Scope of accreditation No. AB 324","parameters_zh":[{"name":"范围","range":"do 20 kA"},{"name":"长时间电流温升试验"}],"search_zh":"温升限值 范围 长时间电流温升试验 IEC 62271-111:2019 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 Scope of accreditation No. AB 324","methodology_zh":"温升限值"},{"_id":"6a5dc9adf1c10c8ce825acab","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Reklozery do układów prądu przemiennego o napięciu do 38 kV","test_object_en":"Reclosers for alternating current systems with voltage up to 38 kV","methodology":"Rezystancja","methodology_en":"Resistance","parameters":[{"name":"Zakres od 10-5 Ω"},{"name":"Prąd probierczy","range":"do 200 A"}],"parameters_en":[{"name":"Range from 10-5 Ω"},{"name":"Test current","range":"do 200 A"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Rezystancja\nZakres:\nZakres od 10-5 Ω\nPrąd probierczy do 200 A","reference":"IEC 62271-111:2019 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 Scope of accreditation No. AB 324","norm_bases":["IEC 62271-111:2019","IEC 62271-1:2017","IEC 62271-1:2017/AMD1:2021","PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06 Scope of accreditation No. AB 324"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Reklozery do układów prądu przemiennego o napięciu do 38 kV Rezystancja\nZakres:\nZakres od 10-5 Ω\nPrąd probierczy do 200 A IEC 62271-111:2019 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 Scope of accreditation No. AB 324 Reklozery do ukladow pradu przemiennego o napieciu do 38 kV Rezystancja\nZakres:\nZakres od 10-5 Ω\nPrad probierczy do 200 A IEC 62271-111:2019 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 Scope of accreditation No. AB 324","categories":["other"],"row_index":113,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Reclosers for alternating current systems with voltage up to 38 kV Resistance Range from 10-5 Ω Test current IEC 62271-111:2019 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 Scope of accreditation No. AB 324","methodology_zh":"电阻","search_zh":"电阻 范围自 10-5 Ω 起 试验电流 IEC 62271-111:2019 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 | PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 Scope of accreditation No. AB 324","parameters_zh":[{"name":"范围自 10-5 Ω 起"},{"name":"试验电流","range":"do 200 A"}]},{"_id":"6a5dc9adf1c10c8ce825acac","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Dławiki i transformatory uziemiające","test_object_en":"Reactors and earthing transformers","methodology":"Wytrzymałość zwarciowa","methodology_en":"Short-circuit withstand strength","parameters":[{"name":"układ jednofazowy","range":"do 63 kA"},{"name":"układ trójfazowy","range":"do 31,5 kA"}],"parameters_en":[{"name":"single-phase system","range":"do 63 kA"},{"name":"three-phase system","range":"do 31,5 kA"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość zwarciowa\nZakres:\nukład jednofazowy do 63 kA\nukład trójfazowy do 31,5 kA","reference":"PN-EN 60076-6:2008 | IEC 60076-6:2007","norm_bases":["PN-EN 60076-6:2008","IEC 60076-6:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Dławiki i transformatory uziemiające Wytrzymałość zwarciowa\nZakres:\nukład jednofazowy do 63 kA\nukład trójfazowy do 31,5 kA PN-EN 60076-6:2008 | IEC 60076-6:2007 Dlawiki i transformatory uziemiajace Wytrzymalosc zwarciowa\nZakres:\nuklad jednofazowy do 63 kA\nuklad trojfazowy do 31,5 kA PN-EN 60076-6:2008 | IEC 60076-6:2007","categories":["other"],"row_index":114,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Reactors and earthing transformers Short-circuit withstand strength single-phase system three-phase system PN-EN 60076-6:2008 | IEC 60076-6:2007","methodology_zh":"短路耐受强度","search_zh":"短路耐受强度 PN-EN 60076-6:2008 | IEC 60076-6:2007"},{"_id":"6a5dc9adf1c10c8ce825acad","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Dławiki i transformatory uziemiające","test_object_en":"Reactors and earthing transformers","methodology":"Graniczne przyrosty temperatury Próby nagrzewania prądem długotrwałym","methodology_en":"Temperature-rise limits Heating tests with continuous current","parameters":[{"name":"Zakres AC","range":"do 20 kA"},{"name":"Zakres DC:","range":"do 4 kA"}],"parameters_en":[{"name":"AC range","range":"do 20 kA"},{"name":"DC range:","range":"do 4 kA"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Graniczne przyrosty temperatury Próby nagrzewania prądem długotrwałym\nZakres:\nZakres AC do 20 kA\nZakres DC: do 4 kA","reference":"PN-EN 60076-6:2008 | IEC 60076-6:2007","norm_bases":["PN-EN 60076-6:2008","IEC 60076-6:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Dławiki i transformatory uziemiające Graniczne przyrosty temperatury Próby nagrzewania prądem długotrwałym\nZakres:\nZakres AC do 20 kA\nZakres DC: do 4 kA PN-EN 60076-6:2008 | IEC 60076-6:2007 Dlawiki i transformatory uziemiajace Graniczne przyrosty temperatury Proby nagrzewania pradem dlugotrwalym\nZakres:\nZakres AC do 20 kA\nZakres DC: do 4 kA PN-EN 60076-6:2008 | IEC 60076-6:2007","categories":["other"],"row_index":115,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Reactors and earthing transformers Temperature-rise limits Heating tests with continuous current AC range DC range: PN-EN 60076-6:2008 | IEC 60076-6:2007"},{"_id":"6a5dc9adf1c10c8ce825acae","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Osprzęt do linii napowietrznych","test_object_en":"Overhead line fittings","methodology":"Wytrzymałość mechaniczna","methodology_en":"Mechanical strength","parameters":[{"name":"Zakres","range":"do15 kN"}],"parameters_en":[{"name":"Range","range":"do15 kN"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość mechaniczna\nZakres do15 kN","reference":"PN-EN 61284:2002 | IEC 61284:1997 | IEC 61284:1997/COR1:1998 | PN-EN 50483-1:2009 | PN-EN 50483-2:2009 | PN-EN 50483-3:2009 | PN-EN 50483-4:2009","norm_bases":["PN-EN 61284:2002","IEC 61284:1997","IEC 61284:1997/COR1:1998","PN-EN 50483-1:2009","PN-EN 50483-2:2009","PN-EN 50483-3:2009","PN-EN 50483-4:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osprzęt do linii napowietrznych Wytrzymałość mechaniczna\nZakres do15 kN PN-EN 61284:2002 | IEC 61284:1997 | IEC 61284:1997/COR1:1998 | PN-EN 50483-1:2009 | PN-EN 50483-2:2009 | PN-EN 50483-3:2009 | PN-EN 50483-4:2009 Osprzet do linii napowietrznych Wytrzymalosc mechaniczna\nZakres do15 kN PN-EN 61284:2002 | IEC 61284:1997 | IEC 61284:1997/COR1:1998 | PN-EN 50483-1:2009 | PN-EN 50483-2:2009 | PN-EN 50483-3:2009 | PN-EN 50483-4:2009","categories":["other"],"row_index":116,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Overhead line fittings Mechanical strength Range PN-EN 61284:2002 | IEC 61284:1997 | IEC 61284:1997/COR1:1998 | PN-EN 50483-1:2009 | PN-EN 50483-2:2009 | PN-EN 50483-3:2009 | PN-EN 50483-4:2009","methodology_zh":"机械强度","parameters_zh":[{"name":"范围","range":"do15 kN"}],"search_zh":"架空线路金具 机械强度 范围 PN-EN 61284:2002 | IEC 61284:1997 | IEC 61284:1997/COR1:1998 | PN-EN 50483-1:2009 | PN-EN 50483-2:2009 | PN-EN 50483-3:2009 | PN-EN 50483-4:2009","test_object_zh":"架空线路金具"},{"_id":"6a5dc9adf1c10c8ce825acaf","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Osprzęt do linii napowietrznych","test_object_en":"Overhead line fittings","methodology":"Graniczne przyrosty temperatury Próby nagrzewania cyklicznego","methodology_en":"Limiting temperature rises Cyclic heating tests","parameters":[{"name":"Zakres","range":"do 20 kA"}],"parameters_en":[{"name":"Range","range":"do 20 kA"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Graniczne przyrosty temperatury Próby nagrzewania cyklicznego\nZakres do 20 kA","reference":"PN-EN 61284:2002 | IEC 61284:1997 | PN-EN 50483-1:2009 | PN-EN 50483-5:2009","norm_bases":["PN-EN 61284:2002","IEC 61284:1997","PN-EN 50483-1:2009","PN-EN 50483-5:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osprzęt do linii napowietrznych Graniczne przyrosty temperatury Próby nagrzewania cyklicznego\nZakres do 20 kA PN-EN 61284:2002 | IEC 61284:1997 | PN-EN 50483-1:2009 | PN-EN 50483-5:2009 Osprzet do linii napowietrznych Graniczne przyrosty temperatury Proby nagrzewania cyklicznego\nZakres do 20 kA PN-EN 61284:2002 | IEC 61284:1997 | PN-EN 50483-1:2009 | PN-EN 50483-5:2009","categories":["other"],"row_index":117,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Overhead line fittings Limiting temperature rises Cyclic heating tests Range PN-EN 61284:2002 | IEC 61284:1997 | PN-EN 50483-1:2009 | PN-EN 50483-5:2009","parameters_zh":[{"name":"范围","range":"do 20 kA"}],"search_zh":"架空线路金具 范围 PN-EN 61284:2002 | IEC 61284:1997 | PN-EN 50483-1:2009 | PN-EN 50483-5:2009","test_object_zh":"架空线路金具"},{"_id":"6a5dc9adf1c10c8ce825acb0","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Osprzęt do linii napowietrznych","test_object_en":"Overhead line fittings","methodology":"Rezystancja","methodology_en":"Resistance","parameters":[{"name":"Zakres","range":"od 10-5 Ω"},{"name":"Prąd probierczy","range":"do 200 A"}],"parameters_en":[{"name":"Range","range":"od 10-5 Ω"},{"name":"Test current","range":"do 200 A"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Rezystancja\nZakres:\nZakres od 10-5 Ω\nPrąd probierczy do 200 A","reference":"PN-EN 61284:2002 | IEC 61284:1997 | PN-EN 50483-1:2009 | PN-EN 50483-5:2009","norm_bases":["PN-EN 61284:2002","IEC 61284:1997","PN-EN 50483-1:2009","PN-EN 50483-5:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osprzęt do linii napowietrznych Rezystancja\nZakres:\nZakres od 10-5 Ω\nPrąd probierczy do 200 A PN-EN 61284:2002 | IEC 61284:1997 | PN-EN 50483-1:2009 | PN-EN 50483-5:2009 Osprzet do linii napowietrznych Rezystancja\nZakres:\nZakres od 10-5 Ω\nPrad probierczy do 200 A PN-EN 61284:2002 | IEC 61284:1997 | PN-EN 50483-1:2009 | PN-EN 50483-5:2009","categories":["other"],"row_index":118,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Overhead line fittings Resistance Range Test current PN-EN 61284:2002 | IEC 61284:1997 | PN-EN 50483-1:2009 | PN-EN 50483-5:2009","parameters_zh":[{"name":"范围","range":"od 10-5 Ω"},{"name":"试验电流","range":"do 200 A"}],"search_zh":"架空线路金具 电阻 范围 试验电流 PN-EN 61284:2002 | IEC 61284:1997 | PN-EN 50483-1:2009 | PN-EN 50483-5:2009","methodology_zh":"电阻","test_object_zh":"架空线路金具"},{"_id":"6a5dc9adf1c10c8ce825acb1","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Osprzęt do linii napowietrznych","test_object_en":"Overhead line fittings","methodology":"Wytrzymałość zwarciowa","methodology_en":"Short-circuit withstand strength","parameters":[{"name":"Zakres","range":"do 150 kA rms / 400 kA peak"},{"name":"Próby wytrzymałości zwarciowej"}],"parameters_en":[{"name":"Range","range":"do 150 kA rms / 400 kA peak"},{"name":"Short-circuit withstand tests"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość zwarciowa\nZakres:\nZakres do 150 kA rms / 400 kA peak\nPróby wytrzymałości zwarciowej","reference":"PN-EN 61284:2002 | IEC 61284:1997 | PN-EN 50483-1:2009 | PN-EN 50483-5:2009 Scope of accreditation No. AB 324","norm_bases":["PN-EN 61284:2002","IEC 61284:1997","PN-EN 50483-1:2009","PN-EN 50483-5:2009 Scope of accreditation No. AB 324"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osprzęt do linii napowietrznych Wytrzymałość zwarciowa\nZakres:\nZakres do 150 kA rms / 400 kA peak\nPróby wytrzymałości zwarciowej PN-EN 61284:2002 | IEC 61284:1997 | PN-EN 50483-1:2009 | PN-EN 50483-5:2009 Scope of accreditation No. AB 324 Osprzet do linii napowietrznych Wytrzymalosc zwarciowa\nZakres:\nZakres do 150 kA rms / 400 kA peak\nProby wytrzymalosci zwarciowej PN-EN 61284:2002 | IEC 61284:1997 | PN-EN 50483-1:2009 | PN-EN 50483-5:2009 Scope of accreditation No. AB 324","categories":["other"],"row_index":119,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Overhead line fittings Short-circuit withstand strength Range Short-circuit withstand tests PN-EN 61284:2002 | IEC 61284:1997 | PN-EN 50483-1:2009 | PN-EN 50483-5:2009 Scope of accreditation No. AB 324","parameters_zh":[{"name":"范围","range":"do 150 kA rms / 400 kA peak"},{"name":"Próby wytrzymałości zwarciowej"}],"search_zh":"架空线路金具 短路耐受强度 范围 PN-EN 61284:2002 | IEC 61284:1997 | PN-EN 50483-1:2009 | PN-EN 50483-5:2009 Scope of accreditation No. AB 324","methodology_zh":"短路耐受强度","test_object_zh":"架空线路金具"},{"_id":"6a5dc9adf1c10c8ce825acb2","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Osprzęt do linii kablowych","test_object_en":"Cable line accessories","methodology":"Wytrzymałość mechaniczna","methodology_en":"Mechanical strength","parameters":[{"name":"Zakres","range":"do 15 kN"}],"parameters_en":[{"name":"Range","range":"do 15 kN"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość mechaniczna\nZakres do 15 kN","reference":"PN-HD 620 S2:2010 | PN-HD 620 S3:2023-04 | PN-HD 629-1-S3:2019-10 | PN-HD 629.2:S2:2006 | PN-HD 629.2 S2:2006/A1:2008 | PN-EN 61442:2005 | PN-EN IEC 61442:2025-08 | IEC 61442:2005 | IEC 61442:2023 | PN-EN IEC 61238-1-1:2020-06 | PN-EN IEC 61238-1-2:2020-06 | PN-EN IEC 61238-1-3:2020-01 | PN-EN IEC 61238-1-3:2020-01/A11:2020-06 | PN-EN 50393:2015-03 | PN-HD 632 S3:2017-03","norm_bases":["PN-HD 620 S2:2010","PN-HD 620 S3:2023-04","PN-HD 629-1-S3:2019-10","PN-HD 629.2:S2:2006","PN-HD 629.2 S2:2006/A1:2008","PN-EN 61442:2005","PN-EN IEC 61442:2025-08","IEC 61442:2005","IEC 61442:2023","PN-EN IEC 61238-1-1:2020-06","PN-EN IEC 61238-1-2:2020-06","PN-EN IEC 61238-1-3:2020-01","PN-EN IEC 61238-1-3:2020-01/A11:2020-06","PN-EN 50393:2015-03","PN-HD 632 S3:2017-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osprzęt do linii kablowych Wytrzymałość mechaniczna\nZakres do 15 kN PN-HD 620 S2:2010 | PN-HD 620 S3:2023-04 | PN-HD 629-1-S3:2019-10 | PN-HD 629.2:S2:2006 | PN-HD 629.2 S2:2006/A1:2008 | PN-EN 61442:2005 | PN-EN IEC 61442:2025-08 | IEC 61442:2005 | IEC 61442:2023 | PN-EN IEC 61238-1-1:2020-06 | PN-EN IEC 61238-1-2:2020-06 | PN-EN IEC 61238-1-3:2020-01 | PN-EN IEC 61238-1-3:2020-01/A11:2020-06 | PN-EN 50393:2015-03 | PN-HD 632 S3:2017-03 Osprzet do linii kablowych Wytrzymalosc mechaniczna\nZakres do 15 kN PN-HD 620 S2:2010 | PN-HD 620 S3:2023-04 | PN-HD 629-1-S3:2019-10 | PN-HD 629.2:S2:2006 | PN-HD 629.2 S2:2006/A1:2008 | PN-EN 61442:2005 | PN-EN IEC 61442:2025-08 | IEC 61442:2005 | IEC 61442:2023 | PN-EN IEC 61238-1-1:2020-06 | PN-EN IEC 61238-1-2:2020-06 | PN-EN IEC 61238-1-3:2020-01 | PN-EN IEC 61238-1-3:2020-01/A11:2020-06 | PN-EN 50393:2015-03 | PN-HD 632 S3:2017-03","categories":["other"],"row_index":120,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cable line accessories Mechanical strength Range PN-HD 620 S2:2010 | PN-HD 620 S3:2023-04 | PN-HD 629-1-S3:2019-10 | PN-HD 629.2:S2:2006 | PN-HD 629.2 S2:2006/A1:2008 | PN-EN 61442:2005 | PN-EN IEC 61442:2025-08 | IEC 61442:2005 | IEC 61442:2023 | PN-EN IEC 61238-1-1:2020-06 | PN-EN IEC 61238-1-2:2020-06 | PN-EN IEC 61238-1-3:2020-01 | PN-EN IEC 61238-1-3:2020-01/A11:2020-06 | PN-EN 50393:2015-03 | PN-HD 632 S3:2017-03","methodology_zh":"机械强度","parameters_zh":[{"name":"范围","range":"do 15 kN"}],"search_zh":"电缆线路附件 机械强度 范围 PN-HD 620 S2:2010 | PN-HD 620 S3:2023-04 | PN-HD 629-1-S3:2019-10 | PN-HD 629.2:S2:2006 | PN-HD 629.2 S2:2006/A1:2008 | PN-EN 61442:2005 | PN-EN IEC 61442:2025-08 | IEC 61442:2005 | IEC 61442:2023 | PN-EN IEC 61238-1-1:2020-06 | PN-EN IEC 61238-1-2:2020-06 | PN-EN IEC 61238-1-3:2020-01 | PN-EN IEC 61238-1-3:2020-01/A11:2020-06 | PN-EN 50393:2015-03 | PN-HD 632 S3:2017-03","test_object_zh":"电缆线路附件"},{"_id":"6a5dc9adf1c10c8ce825acb3","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Osprzęt do linii kablowych","test_object_en":"Cable line accessories","methodology":"Graniczne przyrosty temperatury Próby nagrzewania cyklicznego","methodology_en":"Limiting temperature rises Cyclic heating tests","parameters":[{"name":"Zakres","range":"do 20 kA"}],"parameters_en":[{"name":"Range","range":"do 20 kA"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Graniczne przyrosty temperatury Próby nagrzewania cyklicznego\nZakres do 20 kA","reference":"PN-EN IEC 61238-1-1:2020-06 | PN-EN IEC 61238-1-2:2020-06 | PN-EN IEC 61238-1-3:2020-01 | PN-EN IEC 61238-1-3:2020-01/A11:2020-06","norm_bases":["PN-EN IEC 61238-1-1:2020-06","PN-EN IEC 61238-1-2:2020-06","PN-EN IEC 61238-1-3:2020-01","PN-EN IEC 61238-1-3:2020-01/A11:2020-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osprzęt do linii kablowych Graniczne przyrosty temperatury Próby nagrzewania cyklicznego\nZakres do 20 kA PN-EN IEC 61238-1-1:2020-06 | PN-EN IEC 61238-1-2:2020-06 | PN-EN IEC 61238-1-3:2020-01 | PN-EN IEC 61238-1-3:2020-01/A11:2020-06 Osprzet do linii kablowych Graniczne przyrosty temperatury Proby nagrzewania cyklicznego\nZakres do 20 kA PN-EN IEC 61238-1-1:2020-06 | PN-EN IEC 61238-1-2:2020-06 | PN-EN IEC 61238-1-3:2020-01 | PN-EN IEC 61238-1-3:2020-01/A11:2020-06","categories":["other"],"row_index":121,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cable line accessories Limiting temperature rises Cyclic heating tests Range PN-EN IEC 61238-1-1:2020-06 | PN-EN IEC 61238-1-2:2020-06 | PN-EN IEC 61238-1-3:2020-01 | PN-EN IEC 61238-1-3:2020-01/A11:2020-06","parameters_zh":[{"name":"范围","range":"do 20 kA"}],"search_zh":"电缆线路附件 范围 PN-EN IEC 61238-1-1:2020-06 | PN-EN IEC 61238-1-2:2020-06 | PN-EN IEC 61238-1-3:2020-01 | PN-EN IEC 61238-1-3:2020-01/A11:2020-06","test_object_zh":"电缆线路附件"},{"_id":"6a5dc9adf1c10c8ce825acb4","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Osprzęt do linii kablowych","test_object_en":"Cable line accessories","methodology":"Wytrzymałość zwarciowa","methodology_en":"Short-circuit withstand strength","parameters":[{"name":"Zakres","range":"do 150 kA rms / 400 kA peak"}],"parameters_en":[{"name":"Range","range":"do 150 kA rms / 400 kA peak"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość zwarciowa\nZakres do 150 kA rms / 400 kA peak","reference":"PN-HD 620 S2:2010 | PN-HD 620 S3:2023-04 | PN-HD 629-1-S3:2019-10 | PN-HD 629.2:S2:2006 | PN-HD 629.2 S2:2006/A1:2008 | PN-EN 61442:2005 | PN-EN IEC 61442:2025-08 | IEC 61442:2005 | IEC 61442:2023 | PN-EN IEC 61238-1-1:2020-06 | PN-EN IEC 61238-1-2:2020-06 | PN-EN IEC 61238-1-3:2020-01 | PN-EN IEC 61238-1-3:2020-01/A11:2020-06 | PN-EN 50393:2015-03 | EN 50393:2015 | PN-HD 632 S2:2009 | PN-HD 632 S3:2017-03","norm_bases":["PN-HD 620 S2:2010","PN-HD 620 S3:2023-04","PN-HD 629-1-S3:2019-10","PN-HD 629.2:S2:2006","PN-HD 629.2 S2:2006/A1:2008","PN-EN 61442:2005","PN-EN IEC 61442:2025-08","IEC 61442:2005","IEC 61442:2023","PN-EN IEC 61238-1-1:2020-06","PN-EN IEC 61238-1-2:2020-06","PN-EN IEC 61238-1-3:2020-01","PN-EN IEC 61238-1-3:2020-01/A11:2020-06","PN-EN 50393:2015-03","EN 50393:2015","PN-HD 632 S2:2009","PN-HD 632 S3:2017-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osprzęt do linii kablowych Wytrzymałość zwarciowa\nZakres do 150 kA rms / 400 kA peak PN-HD 620 S2:2010 | PN-HD 620 S3:2023-04 | PN-HD 629-1-S3:2019-10 | PN-HD 629.2:S2:2006 | PN-HD 629.2 S2:2006/A1:2008 | PN-EN 61442:2005 | PN-EN IEC 61442:2025-08 | IEC 61442:2005 | IEC 61442:2023 | PN-EN IEC 61238-1-1:2020-06 | PN-EN IEC 61238-1-2:2020-06 | PN-EN IEC 61238-1-3:2020-01 | PN-EN IEC 61238-1-3:2020-01/A11:2020-06 | PN-EN 50393:2015-03 | EN 50393:2015 | PN-HD 632 S2:2009 | PN-HD 632 S3:2017-03 Osprzet do linii kablowych Wytrzymalosc zwarciowa\nZakres do 150 kA rms / 400 kA peak PN-HD 620 S2:2010 | PN-HD 620 S3:2023-04 | PN-HD 629-1-S3:2019-10 | PN-HD 629.2:S2:2006 | PN-HD 629.2 S2:2006/A1:2008 | PN-EN 61442:2005 | PN-EN IEC 61442:2025-08 | IEC 61442:2005 | IEC 61442:2023 | PN-EN IEC 61238-1-1:2020-06 | PN-EN IEC 61238-1-2:2020-06 | PN-EN IEC 61238-1-3:2020-01 | PN-EN IEC 61238-1-3:2020-01/A11:2020-06 | PN-EN 50393:2015-03 | EN 50393:2015 | PN-HD 632 S2:2009 | PN-HD 632 S3:2017-03","categories":["other"],"row_index":122,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cable line accessories Short-circuit withstand strength Range PN-HD 620 S2:2010 | PN-HD 620 S3:2023-04 | PN-HD 629-1-S3:2019-10 | PN-HD 629.2:S2:2006 | PN-HD 629.2 S2:2006/A1:2008 | PN-EN 61442:2005 | PN-EN IEC 61442:2025-08 | IEC 61442:2005 | IEC 61442:2023 | PN-EN IEC 61238-1-1:2020-06 | PN-EN IEC 61238-1-2:2020-06 | PN-EN IEC 61238-1-3:2020-01 | PN-EN IEC 61238-1-3:2020-01/A11:2020-06 | PN-EN 50393:2015-03 | EN 50393:2015 | PN-HD 632 S2:2009 | PN-HD 632 S3:2017-03","parameters_zh":[{"name":"范围","range":"do 150 kA rms / 400 kA peak"}],"search_zh":"电缆线路附件 短路耐受强度 范围 PN-HD 620 S2:2010 | PN-HD 620 S3:2023-04 | PN-HD 629-1-S3:2019-10 | PN-HD 629.2:S2:2006 | PN-HD 629.2 S2:2006/A1:2008 | PN-EN 61442:2005 | PN-EN IEC 61442:2025-08 | IEC 61442:2005 | IEC 61442:2023 | PN-EN IEC 61238-1-1:2020-06 | PN-EN IEC 61238-1-2:2020-06 | PN-EN IEC 61238-1-3:2020-01 | PN-EN IEC 61238-1-3:2020-01/A11:2020-06 | PN-EN 50393:2015-03 | EN 50393:2015 | PN-HD 632 S2:2009 | PN-HD 632 S3:2017-03","methodology_zh":"短路耐受强度","test_object_zh":"电缆线路附件"},{"_id":"6a5dc9adf1c10c8ce825acb5","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Osprzęt do linii kablowych","test_object_en":"Cable line accessories","methodology":"Rezystancja","methodology_en":"Resistance","parameters":[{"name":"Zakres","range":"od 10-5Ω"},{"name":"Prąd probierczy","range":"do 200 A"}],"parameters_en":[{"name":"Range","range":"od 10-5Ω"},{"name":"Test current","range":"do 200 A"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Rezystancja\nZakres:\nZakres od 10-5Ω\nPrąd probierczy do 200 A","reference":"PN-HD 620 S2:2010 | PN-HD 620 S3:2023-04 | PN-EN IEC 61238-1-1:2020-06 | PN-EN IEC 61238-1-2:2020-06 | PN-EN IEC 61238-1-3:2020-01 | PN-EN IEC 61238-1-3:2020-01/A11:2020-06 | PN-EN 61442:2005 | PN-EN IEC 61442:2025-08 | IEC 61442:2005 | IEC 61442:2023","norm_bases":["PN-HD 620 S2:2010","PN-HD 620 S3:2023-04","PN-EN IEC 61238-1-1:2020-06","PN-EN IEC 61238-1-2:2020-06","PN-EN IEC 61238-1-3:2020-01","PN-EN IEC 61238-1-3:2020-01/A11:2020-06","PN-EN 61442:2005","PN-EN IEC 61442:2025-08","IEC 61442:2005","IEC 61442:2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osprzęt do linii kablowych Rezystancja\nZakres:\nZakres od 10-5Ω\nPrąd probierczy do 200 A PN-HD 620 S2:2010 | PN-HD 620 S3:2023-04 | PN-EN IEC 61238-1-1:2020-06 | PN-EN IEC 61238-1-2:2020-06 | PN-EN IEC 61238-1-3:2020-01 | PN-EN IEC 61238-1-3:2020-01/A11:2020-06 | PN-EN 61442:2005 | PN-EN IEC 61442:2025-08 | IEC 61442:2005 | IEC 61442:2023 Osprzet do linii kablowych Rezystancja\nZakres:\nZakres od 10-5Ω\nPrad probierczy do 200 A PN-HD 620 S2:2010 | PN-HD 620 S3:2023-04 | PN-EN IEC 61238-1-1:2020-06 | PN-EN IEC 61238-1-2:2020-06 | PN-EN IEC 61238-1-3:2020-01 | PN-EN IEC 61238-1-3:2020-01/A11:2020-06 | PN-EN 61442:2005 | PN-EN IEC 61442:2025-08 | IEC 61442:2005 | IEC 61442:2023","categories":["other"],"row_index":123,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cable line accessories Resistance Range Test current PN-HD 620 S2:2010 | PN-HD 620 S3:2023-04 | PN-EN IEC 61238-1-1:2020-06 | PN-EN IEC 61238-1-2:2020-06 | PN-EN IEC 61238-1-3:2020-01 | PN-EN IEC 61238-1-3:2020-01/A11:2020-06 | PN-EN 61442:2005 | PN-EN IEC 61442:2025-08 | IEC 61442:2005 | IEC 61442:2023","parameters_zh":[{"name":"范围","range":"od 10-5Ω"},{"name":"试验电流","range":"do 200 A"}],"search_zh":"电缆线路附件 电阻 范围 试验电流 PN-HD 620 S2:2010 | PN-HD 620 S3:2023-04 | PN-EN IEC 61238-1-1:2020-06 | PN-EN IEC 61238-1-2:2020-06 | PN-EN IEC 61238-1-3:2020-01 | PN-EN IEC 61238-1-3:2020-01/A11:2020-06 | PN-EN 61442:2005 | PN-EN IEC 61442:2025-08 | IEC 61442:2005 | IEC 61442:2023","methodology_zh":"电阻","test_object_zh":"电缆线路附件"},{"_id":"6a5dc9adf1c10c8ce825acb6","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Osprzęt do linii kablowych","test_object_en":"Cable line accessories","methodology":"Rezystancja izolacji","methodology_en":"Insulation resistance","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Rezystancja izolacji","reference":"IEC 61442:2023","norm_bases":["IEC 61442:2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osprzęt do linii kablowych Rezystancja izolacji IEC 61442:2023 Osprzet do linii kablowych Rezystancja izolacji IEC 61442:2023","categories":["construction"],"row_index":124,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cable line accessories Insulation resistance IEC 61442:2023","methodology_zh":"绝缘电阻","search_zh":"电缆线路附件 绝缘电阻 IEC 61442:2023","test_object_zh":"电缆线路附件"},{"_id":"6a5dc9adf1c10c8ce825acb7","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Przewody do linii napowietrznych – przewody stalowo-aluminiowe ACSS","test_object_en":"Conductors for overhead lines – ACSS steel-aluminium conductors","methodology":"Rezystancja","methodology_en":"Resistance","parameters":[{"name":"Zakres","range":"od 10-5 Ω"},{"name":"Prąd probierczy","range":"do 200 A"}],"parameters_en":[{"name":"Range","range":"od 10-5 Ω"},{"name":"Test current","range":"do 200 A"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Rezystancja\nZakres:\nZakres od 10-5 Ω\nPrąd probierczy do 200 A","reference":"PN-EN 50540:2010 | EN 50540:2010","norm_bases":["PN-EN 50540:2010","EN 50540:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przewody do linii napowietrznych – przewody stalowo-aluminiowe ACSS Rezystancja\nZakres:\nZakres od 10-5 Ω\nPrąd probierczy do 200 A PN-EN 50540:2010 | EN 50540:2010 Przewody do linii napowietrznych – przewody stalowo-aluminiowe ACSS Rezystancja\nZakres:\nZakres od 10-5 Ω\nPrad probierczy do 200 A PN-EN 50540:2010 | EN 50540:2010","categories":["materials"],"row_index":125,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Conductors for overhead lines – ACSS steel-aluminium conductors Resistance Range Test current PN-EN 50540:2010 | EN 50540:2010","parameters_zh":[{"name":"范围","range":"od 10-5 Ω"},{"name":"试验电流","range":"do 200 A"}],"search_zh":"电阻 范围 试验电流 PN-EN 50540:2010 | EN 50540:2010","methodology_zh":"电阻"},{"_id":"6a5dc9adf1c10c8ce825acb8","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Szynoprzewody i mosty szynowe WN","test_object_en":"HV busbar trunking systems and busbar bridges","methodology":"Graniczne przyrosty temperatury","methodology_en":"Temperature-rise limits","parameters":[{"name":"Zakres","range":"do 20 kA"},{"name":"Próby nagrzewania prądem długotrwałym"}],"parameters_en":[{"name":"Range","range":"do 20 kA"},{"name":"Temperature-rise tests with continuous current"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Graniczne przyrosty temperatury\nZakres:\nZakres do 20 kA\nPróby nagrzewania prądem długotrwałym","reference":"PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 ANSI/IEEE C37.23-2015","norm_bases":["PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-1:2017","IEC 62271-1:2017/AMD1:2021 ANSI/IEEE C37.23-2015"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Szynoprzewody i mosty szynowe WN Graniczne przyrosty temperatury\nZakres:\nZakres do 20 kA\nPróby nagrzewania prądem długotrwałym PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 ANSI/IEEE C37.23-2015 Szynoprzewody i mosty szynowe WN Graniczne przyrosty temperatury\nZakres:\nZakres do 20 kA\nProby nagrzewania pradem dlugotrwalym PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 ANSI/IEEE C37.23-2015","categories":["other"],"row_index":126,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"HV busbar trunking systems and busbar bridges Temperature-rise limits Range Temperature-rise tests with continuous current PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 ANSI/IEEE C37.23-2015","parameters_zh":[{"name":"范围","range":"do 20 kA"},{"name":"长时间电流温升试验"}],"search_zh":"高压母线槽与母线桥 温升限值 范围 长时间电流温升试验 PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 ANSI/IEEE C37.23-2015","methodology_zh":"温升限值","test_object_zh":"高压母线槽与母线桥"},{"_id":"6a5dc9adf1c10c8ce825acb9","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Szynoprzewody i mosty szynowe WN","test_object_en":"HV busbar trunking systems and busbar bridges","methodology":"Trwałość znakowania","methodology_en":"Durability of marking","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Trwałość znakowania","reference":"PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 ANSI/IEEE C37.23-2015","norm_bases":["PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-1:2017","IEC 62271-1:2017/AMD1:2021 ANSI/IEEE C37.23-2015"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Szynoprzewody i mosty szynowe WN Trwałość znakowania PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 ANSI/IEEE C37.23-2015 Szynoprzewody i mosty szynowe WN Trwalosc znakowania PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 ANSI/IEEE C37.23-2015","categories":["other"],"row_index":127,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"HV busbar trunking systems and busbar bridges Durability of marking PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 ANSI/IEEE C37.23-2015","methodology_zh":"标识耐久性","search_zh":"高压母线槽与母线桥 标识耐久性 PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 ANSI/IEEE C37.23-2015","test_object_zh":"高压母线槽与母线桥"},{"_id":"6a5dc9adf1c10c8ce825acba","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Szynoprzewody i mosty szynowe WN","test_object_en":"HV busbar trunking systems and busbar bridges","methodology":"Rezystancja","methodology_en":"Resistance","parameters":[{"name":"Zakres od 10-5 Ω"},{"name":"Prąd probierczy","range":"do 200 A"}],"parameters_en":[{"name":"Range from 10-5 Ω"},{"name":"Test current","range":"do 200 A"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Rezystancja\nZakres:\nZakres od 10-5 Ω\nPrąd probierczy do 200 A","reference":"PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 ANSI/IEEE C37.23-2015","norm_bases":["PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-1:2017","IEC 62271-1:2017/AMD1:2021 ANSI/IEEE C37.23-2015"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Szynoprzewody i mosty szynowe WN Rezystancja\nZakres:\nZakres od 10-5 Ω\nPrąd probierczy do 200 A PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 ANSI/IEEE C37.23-2015 Szynoprzewody i mosty szynowe WN Rezystancja\nZakres:\nZakres od 10-5 Ω\nPrad probierczy do 200 A PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 ANSI/IEEE C37.23-2015","categories":["other"],"row_index":128,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"HV busbar trunking systems and busbar bridges Resistance Range from 10-5 Ω Test current PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 ANSI/IEEE C37.23-2015","methodology_zh":"电阻","search_zh":"高压母线槽与母线桥 电阻 范围自 10-5 Ω 起 试验电流 PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 ANSI/IEEE C37.23-2015","parameters_zh":[{"name":"范围自 10-5 Ω 起"},{"name":"试验电流","range":"do 200 A"}],"test_object_zh":"高压母线槽与母线桥"},{"_id":"6a5dc9adf1c10c8ce825acbb","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Szynoprzewody i mosty szynowe WN","test_object_en":"HV busbar trunking systems and busbar bridges","methodology":"Wytrzymałość zwarciowa, Zakres do 150 kA rms / 400 kA peak","methodology_en":"Short-circuit withstand strength, Range up to 150 kA rms / 400 kA peak","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość zwarciowa, Zakres do 150 kA rms / 400 kA peak","reference":"PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 ANSI/IEEE C37.23-2015","norm_bases":["PN-EN 62271-1:2018-02","PN-EN 62271-1:2018-02/A1:2022-06","IEC 62271-1:2017","IEC 62271-1:2017/AMD1:2021 ANSI/IEEE C37.23-2015"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Szynoprzewody i mosty szynowe WN Wytrzymałość zwarciowa, Zakres do 150 kA rms / 400 kA peak PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 ANSI/IEEE C37.23-2015 Szynoprzewody i mosty szynowe WN Wytrzymalosc zwarciowa, Zakres do 150 kA rms / 400 kA peak PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 ANSI/IEEE C37.23-2015","categories":["other"],"row_index":129,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"HV busbar trunking systems and busbar bridges Short-circuit withstand strength, Range up to 150 kA rms / 400 kA peak PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 ANSI/IEEE C37.23-2015","search_zh":"高压母线槽与母线桥 PN-EN 62271-1:2018-02 | PN-EN 62271-1:2018-02/A1:2022-06 | IEC 62271-1:2017 | IEC 62271-1:2017/AMD1:2021 ANSI/IEEE C37.23-2015","test_object_zh":"高压母线槽与母线桥"},{"_id":"6a5dc9adf1c10c8ce825acbc","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Szynoprzewody i mosty szynowe niskiego napięcia","test_object_en":"Low-voltage busbar trunking systems and busbar bridges","methodology":"Graniczne przyrosty temperatury","methodology_en":"Temperature-rise limits","parameters":[{"name":"Zakres","range":"do 20 kA"},{"name":"Próby nagrzewania prądem długotrwałym"}],"parameters_en":[{"name":"Range","range":"do 20 kA"},{"name":"Temperature-rise tests with continuous current"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Graniczne przyrosty temperatury\nZakres:\nZakres do 20 kA\nPróby nagrzewania prądem długotrwałym","reference":"PN-EN 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012 | PN-EN 61439-6:2013-03/Ap1:2014-12","norm_bases":["PN-EN 61439-1:2021-10","IEC 61439-1:2020","PN-EN 61439-6:2013-03","IEC 61439-6:2012","PN-EN 61439-6:2013-03/Ap1:2014-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Szynoprzewody i mosty szynowe niskiego napięcia Graniczne przyrosty temperatury\nZakres:\nZakres do 20 kA\nPróby nagrzewania prądem długotrwałym PN-EN 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012 | PN-EN 61439-6:2013-03/Ap1:2014-12 Szynoprzewody i mosty szynowe niskiego napiecia Graniczne przyrosty temperatury\nZakres:\nZakres do 20 kA\nProby nagrzewania pradem dlugotrwalym PN-EN 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012 | PN-EN 61439-6:2013-03/Ap1:2014-12","categories":["other"],"row_index":130,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Low-voltage busbar trunking systems and busbar bridges Temperature-rise limits Range Temperature-rise tests with continuous current PN-EN 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012 | PN-EN 61439-6:2013-03/Ap1:2014-12","parameters_zh":[{"name":"范围","range":"do 20 kA"},{"name":"长时间电流温升试验"}],"search_zh":"低压母线槽与母线桥 温升限值 范围 长时间电流温升试验 PN-EN 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012 | PN-EN 61439-6:2013-03/Ap1:2014-12","methodology_zh":"温升限值","test_object_zh":"低压母线槽与母线桥"},{"_id":"6a5dc9adf1c10c8ce825acbd","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Szynoprzewody i mosty szynowe niskiego napięcia","test_object_en":"Low-voltage busbar trunking systems and busbar bridges","methodology":"Graniczne przyrosty temperatury., Próba nagrzewania cyklicznego, Zakres do 20 kA","methodology_en":"Temperature-rise limits., Cyclic heating test, Range up to 20 kA","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Graniczne przyrosty temperatury., Próba nagrzewania cyklicznego, Zakres do 20 kA","reference":"PN-EN 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012 | PN-EN 61439-6:2013-03/Ap1:2014-12","norm_bases":["PN-EN 61439-1:2021-10","IEC 61439-1:2020","PN-EN 61439-6:2013-03","IEC 61439-6:2012","PN-EN 61439-6:2013-03/Ap1:2014-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Szynoprzewody i mosty szynowe niskiego napięcia Graniczne przyrosty temperatury., Próba nagrzewania cyklicznego, Zakres do 20 kA PN-EN 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012 | PN-EN 61439-6:2013-03/Ap1:2014-12 Szynoprzewody i mosty szynowe niskiego napiecia Graniczne przyrosty temperatury., Proba nagrzewania cyklicznego, Zakres do 20 kA PN-EN 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012 | PN-EN 61439-6:2013-03/Ap1:2014-12","categories":["other"],"row_index":131,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Low-voltage busbar trunking systems and busbar bridges Temperature-rise limits., Cyclic heating test, Range up to 20 kA PN-EN 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012 | PN-EN 61439-6:2013-03/Ap1:2014-12","search_zh":"低压母线槽与母线桥 PN-EN 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012 | PN-EN 61439-6:2013-03/Ap1:2014-12","test_object_zh":"低压母线槽与母线桥"},{"_id":"6a5dc9adf1c10c8ce825acbe","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Szynoprzewody i mosty szynowe niskiego napięcia","test_object_en":"Low-voltage busbar trunking systems and busbar bridges","methodology":"Wytrzymałość zwarciowa, Zakres do 150 kA rms / 400 kA peak","methodology_en":"Short-circuit withstand strength, Range up to 150 kA rms / 400 kA peak","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość zwarciowa, Zakres do 150 kA rms / 400 kA peak","reference":"PN-EN 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012 | PN-EN 61439-6:2013-03/Ap1:2014-12","norm_bases":["PN-EN 61439-1:2021-10","IEC 61439-1:2020","PN-EN 61439-6:2013-03","IEC 61439-6:2012","PN-EN 61439-6:2013-03/Ap1:2014-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Szynoprzewody i mosty szynowe niskiego napięcia Wytrzymałość zwarciowa, Zakres do 150 kA rms / 400 kA peak PN-EN 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012 | PN-EN 61439-6:2013-03/Ap1:2014-12 Szynoprzewody i mosty szynowe niskiego napiecia Wytrzymalosc zwarciowa, Zakres do 150 kA rms / 400 kA peak PN-EN 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012 | PN-EN 61439-6:2013-03/Ap1:2014-12","categories":["other"],"row_index":132,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Low-voltage busbar trunking systems and busbar bridges Short-circuit withstand strength, Range up to 150 kA rms / 400 kA peak PN-EN 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012 | PN-EN 61439-6:2013-03/Ap1:2014-12","search_zh":"低压母线槽与母线桥 PN-EN 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012 | PN-EN 61439-6:2013-03/Ap1:2014-12","test_object_zh":"低压母线槽与母线桥"},{"_id":"6a5dc9adf1c10c8ce825acbf","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Szynoprzewody i mosty szynowe niskiego napięcia","test_object_en":"Low-voltage busbar trunking systems and busbar bridges","methodology":"Wytrzymałość zwarciowa, Próby prądem stałym, Zakres do 40 kA (prąd krótkotrwały)","methodology_en":"Short-circuit withstand, Direct current tests, Range up to 40 kA (short-time current)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość zwarciowa, Próby prądem stałym, Zakres do 40 kA (prąd krótkotrwały)","reference":"PN-EN 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012 | PN-EN 61439-6:2013-03/Ap1:2014-12","norm_bases":["PN-EN 61439-1:2021-10","IEC 61439-1:2020","PN-EN 61439-6:2013-03","IEC 61439-6:2012","PN-EN 61439-6:2013-03/Ap1:2014-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Szynoprzewody i mosty szynowe niskiego napięcia Wytrzymałość zwarciowa, Próby prądem stałym, Zakres do 40 kA (prąd krótkotrwały) PN-EN 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012 | PN-EN 61439-6:2013-03/Ap1:2014-12 Szynoprzewody i mosty szynowe niskiego napiecia Wytrzymalosc zwarciowa, Proby pradem stalym, Zakres do 40 kA (prad krotkotrwaly) PN-EN 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012 | PN-EN 61439-6:2013-03/Ap1:2014-12","categories":["other"],"row_index":133,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Low-voltage busbar trunking systems and busbar bridges Short-circuit withstand, Direct current tests, Range up to 40 kA (short-time current) PN-EN 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012 | PN-EN 61439-6:2013-03/Ap1:2014-12","search_zh":"低压母线槽与母线桥 PN-EN 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012 | PN-EN 61439-6:2013-03/Ap1:2014-12","test_object_zh":"低压母线槽与母线桥"},{"_id":"6a5dc9adf1c10c8ce825acc0","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Szynoprzewody i mosty szynowe niskiego napięcia","test_object_en":"Low-voltage busbar trunking systems and busbar bridges","methodology":"Graniczne przyrosty temperatury, Próby nagrzewania prądem stałym do 4 kA","methodology_en":"Temperature-rise limits, Heating tests with direct current up to 4 kA","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Graniczne przyrosty temperatury, Próby nagrzewania prądem stałym do 4 kA","reference":"PN-EN 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012 | PN-EN 61439-6:2013-03/Ap1:2014-12","norm_bases":["PN-EN 61439-1:2021-10","IEC 61439-1:2020","PN-EN 61439-6:2013-03","IEC 61439-6:2012","PN-EN 61439-6:2013-03/Ap1:2014-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Szynoprzewody i mosty szynowe niskiego napięcia Graniczne przyrosty temperatury, Próby nagrzewania prądem stałym do 4 kA PN-EN 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012 | PN-EN 61439-6:2013-03/Ap1:2014-12 Szynoprzewody i mosty szynowe niskiego napiecia Graniczne przyrosty temperatury, Proby nagrzewania pradem stalym do 4 kA PN-EN 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012 | PN-EN 61439-6:2013-03/Ap1:2014-12","categories":["other"],"row_index":134,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Low-voltage busbar trunking systems and busbar bridges Temperature-rise limits, Heating tests with direct current up to 4 kA PN-EN 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012 | PN-EN 61439-6:2013-03/Ap1:2014-12","search_zh":"低压母线槽与母线桥 PN-EN 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012 | PN-EN 61439-6:2013-03/Ap1:2014-12","test_object_zh":"低压母线槽与母线桥"},{"_id":"6a5dc9adf1c10c8ce825acc1","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Szynoprzewody i mosty szynowe niskiego napięcia","test_object_en":"Low-voltage busbar trunking systems and busbar bridges","methodology":"Rezystancja","methodology_en":"Resistance","parameters":[{"name":"Zakres od 10-5 Ω"},{"name":"Prąd probierczy","range":"do 200 A"}],"parameters_en":[{"name":"Range from 10-5 Ω"},{"name":"Test current","range":"do 200 A"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Rezystancja\nZakres:\nZakres od 10-5 Ω\nPrąd probierczy do 200 A","reference":"PN-EN 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012 | PN-EN 61439-6:2013-03/Ap1:2014-12","norm_bases":["PN-EN 61439-1:2021-10","IEC 61439-1:2020","PN-EN 61439-6:2013-03","IEC 61439-6:2012","PN-EN 61439-6:2013-03/Ap1:2014-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Szynoprzewody i mosty szynowe niskiego napięcia Rezystancja\nZakres:\nZakres od 10-5 Ω\nPrąd probierczy do 200 A PN-EN 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012 | PN-EN 61439-6:2013-03/Ap1:2014-12 Szynoprzewody i mosty szynowe niskiego napiecia Rezystancja\nZakres:\nZakres od 10-5 Ω\nPrad probierczy do 200 A PN-EN 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012 | PN-EN 61439-6:2013-03/Ap1:2014-12","categories":["other"],"row_index":135,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Low-voltage busbar trunking systems and busbar bridges Resistance Range from 10-5 Ω Test current PN-EN 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012 | PN-EN 61439-6:2013-03/Ap1:2014-12","methodology_zh":"电阻","search_zh":"低压母线槽与母线桥 电阻 范围自 10-5 Ω 起 试验电流 PN-EN 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012 | PN-EN 61439-6:2013-03/Ap1:2014-12","parameters_zh":[{"name":"范围自 10-5 Ω 起"},{"name":"试验电流","range":"do 200 A"}],"test_object_zh":"低压母线槽与母线桥"},{"_id":"6a5dc9adf1c10c8ce825acc2","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Rozdzielnice i sterownice niskonapięciowe","test_object_en":"Low-voltage switchgear and controlgear assemblies","methodology":"Graniczne przyrosty temperatury","methodology_en":"Temperature-rise limits","parameters":[{"name":"Zakres","range":"do 20 kA"},{"name":"Próby nagrzewania prądem długotrwałym"}],"parameters_en":[{"name":"Range","range":"do 20 kA"},{"name":"Temperature-rise tests with continuous current"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Graniczne przyrosty temperatury\nZakres:\nZakres do 20 kA\nPróby nagrzewania prądem długotrwałym","reference":"PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | IEC 61439-4:2023 | PN-EN 61439-4:2013-06 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023","norm_bases":["PN-EN IEC 61439-1:2021-10","IEC 61439-1:2020","PN-EN IEC 61439-2:2021-10","IEC 61439-2:2020","PN-EN IEC 61439-3:2025-09","IEC 61439-3:2024","IEC 61439-4:2023","PN-EN 61439-4:2013-06","PN-EN IEC 61439-5:2024-04","IEC 61439-5:2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rozdzielnice i sterownice niskonapięciowe Graniczne przyrosty temperatury\nZakres:\nZakres do 20 kA\nPróby nagrzewania prądem długotrwałym PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | IEC 61439-4:2023 | PN-EN 61439-4:2013-06 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023 Rozdzielnice i sterownice niskonapieciowe Graniczne przyrosty temperatury\nZakres:\nZakres do 20 kA\nProby nagrzewania pradem dlugotrwalym PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | IEC 61439-4:2023 | PN-EN 61439-4:2013-06 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023","categories":["other"],"row_index":136,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Low-voltage switchgear and controlgear assemblies Temperature-rise limits Range Temperature-rise tests with continuous current PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | IEC 61439-4:2023 | PN-EN 61439-4:2013-06 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023","parameters_zh":[{"name":"范围","range":"do 20 kA"},{"name":"长时间电流温升试验"}],"search_zh":"低压成套开关设备与控制设备 温升限值 范围 长时间电流温升试验 PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | IEC 61439-4:2023 | PN-EN 61439-4:2013-06 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023","methodology_zh":"温升限值","test_object_zh":"低压成套开关设备与控制设备"},{"_id":"6a5dc9adf1c10c8ce825acc3","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Rozdzielnice i sterownice niskonapięciowe","test_object_en":"Low-voltage switchgear and controlgear assemblies","methodology":"Wytrzymałość zwarciowa","methodology_en":"Short-circuit withstand strength","parameters":[{"name":"Zakres","range":"do 150 kA rms / 400 kA peak"}],"parameters_en":[{"name":"Range","range":"do 150 kA rms / 400 kA peak"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość zwarciowa\nZakres do 150 kA rms / 400 kA peak","reference":"PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | IEC 61439-4:2023 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023","norm_bases":["PN-EN IEC 61439-1:2021-10","IEC 61439-1:2020","PN-EN IEC 61439-2:2021-10","IEC 61439-2:2020","PN-EN IEC 61439-3:2025-09","IEC 61439-3:2024","PN-EN 61439-4:2013-06","IEC 61439-4:2023","PN-EN IEC 61439-5:2024-04","IEC 61439-5:2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rozdzielnice i sterownice niskonapięciowe Wytrzymałość zwarciowa\nZakres do 150 kA rms / 400 kA peak PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | IEC 61439-4:2023 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023 Rozdzielnice i sterownice niskonapieciowe Wytrzymalosc zwarciowa\nZakres do 150 kA rms / 400 kA peak PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | IEC 61439-4:2023 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023","categories":["other"],"row_index":137,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Low-voltage switchgear and controlgear assemblies Short-circuit withstand strength Range PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | IEC 61439-4:2023 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023","parameters_zh":[{"name":"范围","range":"do 150 kA rms / 400 kA peak"}],"search_zh":"低压成套开关设备与控制设备 短路耐受强度 范围 PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | IEC 61439-4:2023 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023","methodology_zh":"短路耐受强度","test_object_zh":"低压成套开关设备与控制设备"},{"_id":"6a5dc9adf1c10c8ce825acc4","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Rozdzielnice i sterownice niskonapięciowe","test_object_en":"Low-voltage switchgear and controlgear assemblies","methodology":"Prawidłowość działania mechanicznego","methodology_en":"Correctness of mechanical operation","parameters":[{"name":"Zakres","range":"do 15 KN"}],"parameters_en":[{"name":"Range","range":"do 15 KN"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Prawidłowość działania mechanicznego\nZakres do 15 KN","reference":"PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | IEC 61439-4:2023 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023","norm_bases":["PN-EN IEC 61439-1:2021-10","IEC 61439-1:2020","PN-EN IEC 61439-2:2021-10","IEC 61439-2:2020","PN-EN IEC 61439-3:2025-09","IEC 61439-3:2024","PN-EN 61439-4:2013-06","IEC 61439-4:2023","PN-EN IEC 61439-5:2024-04","IEC 61439-5:2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rozdzielnice i sterownice niskonapięciowe Prawidłowość działania mechanicznego\nZakres do 15 KN PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | IEC 61439-4:2023 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023 Rozdzielnice i sterownice niskonapieciowe Prawidlowosc dzialania mechanicznego\nZakres do 15 KN PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | IEC 61439-4:2023 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023","categories":["other"],"row_index":138,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Low-voltage switchgear and controlgear assemblies Correctness of mechanical operation Range PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | IEC 61439-4:2023 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023","parameters_zh":[{"name":"范围","range":"do 15 KN"}],"search_zh":"低压成套开关设备与控制设备 机械动作的正确性 范围 PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | IEC 61439-4:2023 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023","test_object_zh":"低压成套开关设备与控制设备","methodology_zh":"机械动作的正确性"},{"_id":"6a5dc9adf1c10c8ce825acc5","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Rozdzielnice i sterownice niskonapięciowe","test_object_en":"Low-voltage switchgear and controlgear assemblies","methodology":"Podnoszenie, Lifting","methodology_en":"Lifting, Lifting","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Podnoszenie, Lifting","reference":"PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023","norm_bases":["PN-EN IEC 61439-1:2021-10","IEC 61439-1:2020","PN-EN IEC 61439-5:2024-04","IEC 61439-5:2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rozdzielnice i sterownice niskonapięciowe Podnoszenie, Lifting PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023 Rozdzielnice i sterownice niskonapieciowe Podnoszenie, Lifting PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023","categories":["other"],"row_index":139,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Low-voltage switchgear and controlgear assemblies Lifting, Lifting PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023","search_zh":"低压成套开关设备与控制设备 PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023","test_object_zh":"低压成套开关设备与控制设备"},{"_id":"6a5dc9adf1c10c8ce825acc6","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Rozdzielnice i sterownice niskonapięciowe","test_object_en":"Low-voltage switchgear and controlgear assemblies","methodology":"Poosiowe obciążenia metalowych zaprasek","methodology_en":"Axial loading of metal crimps","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Poosiowe obciążenia metalowych zaprasek","reference":"PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023","norm_bases":["PN-EN IEC 61439-1:2021-10","IEC 61439-1:2020","PN-EN IEC 61439-5:2024-04","IEC 61439-5:2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rozdzielnice i sterownice niskonapięciowe Poosiowe obciążenia metalowych zaprasek PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023 Rozdzielnice i sterownice niskonapieciowe Poosiowe obciazenia metalowych zaprasek PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023","categories":["materials"],"row_index":140,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Low-voltage switchgear and controlgear assemblies Axial loading of metal crimps PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023","search_zh":"低压成套开关设备与控制设备 PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023","test_object_zh":"低压成套开关设备与控制设备"},{"_id":"6a5dc9adf1c10c8ce825acc7","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Rozdzielnice i sterownice niskonapięciowe","test_object_en":"Low-voltage switchgear and controlgear assemblies","methodology":"Rezystancja","methodology_en":"Resistance","parameters":[{"name":"Zakres","range":"od 10-5 Ω"},{"name":"Prąd probierczy","range":"do 200 A"},{"name":"Próby głównych torów prądowych"}],"parameters_en":[{"name":"Range","range":"od 10-5 Ω"},{"name":"Test current","range":"do 200 A"},{"name":"Tests of main current paths"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Rezystancja\nZakres:\nZakres od 10-5 Ω\nPrąd probierczy do 200 A\nPróby głównych torów prądowych","reference":"PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | IEC 61439-4:2023 | IEC 61439-5:2014 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023","norm_bases":["PN-EN IEC 61439-1:2021-10","IEC 61439-1:2020","PN-EN IEC 61439-2:2021-10","IEC 61439-2:2020","PN-EN IEC 61439-3:2025-09","IEC 61439-3:2024","PN-EN 61439-4:2013-06","IEC 61439-4:2023","IEC 61439-5:2014","PN-EN IEC 61439-5:2024-04","IEC 61439-5:2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rozdzielnice i sterownice niskonapięciowe Rezystancja\nZakres:\nZakres od 10-5 Ω\nPrąd probierczy do 200 A\nPróby głównych torów prądowych PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | IEC 61439-4:2023 | IEC 61439-5:2014 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023 Rozdzielnice i sterownice niskonapieciowe Rezystancja\nZakres:\nZakres od 10-5 Ω\nPrad probierczy do 200 A\nProby glownych torow pradowych PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | IEC 61439-4:2023 | IEC 61439-5:2014 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023","categories":["other"],"row_index":141,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Low-voltage switchgear and controlgear assemblies Resistance Range Test current Tests of main current paths PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | IEC 61439-4:2023 | IEC 61439-5:2014 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023","parameters_zh":[{"name":"范围","range":"od 10-5 Ω"},{"name":"试验电流","range":"do 200 A"},{"name":"Próby głównych torów prądowych"}],"search_zh":"低压成套开关设备与控制设备 电阻 范围 试验电流 PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | IEC 61439-4:2023 | IEC 61439-5:2014 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023","methodology_zh":"电阻","test_object_zh":"低压成套开关设备与控制设备"},{"_id":"6a5dc9adf1c10c8ce825acc8","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Rozdzielnice i sterownice niskonapięciowe","test_object_en":"Low-voltage switchgear and controlgear assemblies","methodology":"Rezystancja izolacji","methodology_en":"Insulation resistance","parameters":[{"name":"Zakres","range":"od 1 MΩ do 1000 GΩ"}],"parameters_en":[{"name":"Range","range":"od 1 MΩ do 1000 GΩ"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Rezystancja izolacji\nZakres od 1 MΩ do 1000 GΩ","reference":"PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020","norm_bases":["PN-EN IEC 61439-1:2021-10","IEC 61439-1:2020"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rozdzielnice i sterownice niskonapięciowe Rezystancja izolacji\nZakres od 1 MΩ do 1000 GΩ PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 Rozdzielnice i sterownice niskonapieciowe Rezystancja izolacji\nZakres od 1 MΩ do 1000 GΩ PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020","categories":["construction"],"row_index":142,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Low-voltage switchgear and controlgear assemblies Insulation resistance Range PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020","parameters_zh":[{"name":"范围","range":"od 1 MΩ do 1000 GΩ"}],"search_zh":"低压成套开关设备与控制设备 绝缘电阻 范围 PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020","test_object_zh":"低压成套开关设备与控制设备","methodology_zh":"绝缘电阻"},{"_id":"6a5dc9adf1c10c8ce825acc9","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Rozdzielnice i sterownice niskonapięciowe","test_object_en":"Low-voltage switchgear and controlgear assemblies","methodology":"Wytrzymałość zwarciowa, Próby prądem stałym, Zakres do 40 kA","methodology_en":"Short-circuit withstand, Direct current tests, Range up to 40 kA","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość zwarciowa, Próby prądem stałym, Zakres do 40 kA","reference":"PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | IEC 61439-4:2023 | IEC 61439-4:2012 | IEC 61439-5:2014 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023","norm_bases":["PN-EN IEC 61439-1:2021-10","IEC 61439-1:2020","PN-EN IEC 61439-2:2021-10","IEC 61439-2:2020","PN-EN IEC 61439-3:2025-09","IEC 61439-3:2024","PN-EN 61439-4:2013-06","IEC 61439-4:2023","IEC 61439-4:2012","IEC 61439-5:2014","PN-EN IEC 61439-5:2024-04","IEC 61439-5:2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rozdzielnice i sterownice niskonapięciowe Wytrzymałość zwarciowa, Próby prądem stałym, Zakres do 40 kA PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | IEC 61439-4:2023 | IEC 61439-4:2012 | IEC 61439-5:2014 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023 Rozdzielnice i sterownice niskonapieciowe Wytrzymalosc zwarciowa, Proby pradem stalym, Zakres do 40 kA PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | IEC 61439-4:2023 | IEC 61439-4:2012 | IEC 61439-5:2014 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023","categories":["other"],"row_index":143,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Low-voltage switchgear and controlgear assemblies Short-circuit withstand, Direct current tests, Range up to 40 kA PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | IEC 61439-4:2023 | IEC 61439-4:2012 | IEC 61439-5:2014 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023","search_zh":"低压成套开关设备与控制设备 PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | IEC 61439-4:2023 | IEC 61439-4:2012 | IEC 61439-5:2014 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023","test_object_zh":"低压成套开关设备与控制设备"},{"_id":"6a5dc9adf1c10c8ce825acca","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Rozdzielnice i sterownice niskonapięciowe","test_object_en":"Low-voltage switchgear and controlgear assemblies","methodology":"Graniczne przyrosty temperatury, Próby nagrzewania prądem stałym Zakres: do 4 kA","methodology_en":"Temperature-rise limits, Heating tests with direct current Range: up to 4 kA","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Graniczne przyrosty temperatury, Próby nagrzewania prądem stałym Zakres: do 4 kA","reference":"PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | IEC 61439-4:2023 | IEC 61439-4: 2012 | IEC 61439-5:2014 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023 Scope of accreditation No. AB 324","norm_bases":["PN-EN IEC 61439-1:2021-10","IEC 61439-1:2020","PN-EN IEC 61439-2:2021-10","IEC 61439-2:2020","PN-EN IEC 61439-3:2025-09","IEC 61439-3:2024","PN-EN 61439-4:2013-06","IEC 61439-4:2023","IEC 61439-4: 2012","IEC 61439-5:2014","PN-EN IEC 61439-5:2024-04","IEC 61439-5:2023 Scope of accreditation No. AB 324"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rozdzielnice i sterownice niskonapięciowe Graniczne przyrosty temperatury, Próby nagrzewania prądem stałym Zakres: do 4 kA PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | IEC 61439-4:2023 | IEC 61439-4: 2012 | IEC 61439-5:2014 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023 Scope of accreditation No. AB 324 Rozdzielnice i sterownice niskonapieciowe Graniczne przyrosty temperatury, Proby nagrzewania pradem stalym Zakres: do 4 kA PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | IEC 61439-4:2023 | IEC 61439-4: 2012 | IEC 61439-5:2014 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023 Scope of accreditation No. AB 324","categories":["other"],"row_index":144,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Low-voltage switchgear and controlgear assemblies Temperature-rise limits, Heating tests with direct current Range: up to 4 kA PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | IEC 61439-4:2023 | IEC 61439-4: 2012 | IEC 61439-5:2014 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023 Scope of accreditation No. AB 324","search_zh":"低压成套开关设备与控制设备 PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | IEC 61439-4:2023 | IEC 61439-4: 2012 | IEC 61439-5:2014 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023 Scope of accreditation No. AB 324","test_object_zh":"低压成套开关设备与控制设备"},{"_id":"6a5dc9adf1c10c8ce825accb","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Rozdzielnice i sterownice niskonapięciowe, Low-voltage switchgear","test_object_en":"Low-voltage switchgear and controlgear assemblies","methodology":"Ochrona przed porażeniem prądem elektrycznym, Ochrona przed niezamierzonym dotykiem bezpośrednim części niebezpiecznych czynnych, Protection against electric shock, Protection against unintentional direct contact","methodology_en":"Protection against electric shock, Protection against unintentional direct contact with hazardous live parts","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Ochrona przed porażeniem prądem elektrycznym, Ochrona przed niezamierzonym dotykiem bezpośrednim części niebezpiecznych czynnych, Protection against electric shock, Protection against unintentional direct contact","reference":"PN-EN 50274:2004 | EN 50274:2002","norm_bases":["PN-EN 50274:2004","EN 50274:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rozdzielnice i sterownice niskonapięciowe, Low-voltage switchgear Ochrona przed porażeniem prądem elektrycznym, Ochrona przed niezamierzonym dotykiem bezpośrednim części niebezpiecznych czynnych, Protection against electric shock, Protection against unintentional direct contact PN-EN 50274:2004 | EN 50274:2002 Rozdzielnice i sterownice niskonapieciowe, Low-voltage switchgear Ochrona przed porazeniem pradem elektrycznym, Ochrona przed niezamierzonym dotykiem bezposrednim czesci niebezpiecznych czynnych, Protection against electric shock, Protection against unintentional direct contact PN-EN 50274:2004 | EN 50274:2002","categories":["other"],"row_index":145,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Low-voltage switchgear and controlgear assemblies Protection against electric shock, Protection against unintentional direct contact with hazardous live parts PN-EN 50274:2004 | EN 50274:2002"},{"_id":"6a5dc9adf1c10c8ce825accc","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Rozdzielnice i sterownice niskonapięciowe, Low-voltage switchgear","test_object_en":"Low-voltage switchgear and controlgear assemblies","methodology":"Odstępy izolacyjne powietrzne i powierzchniowe","methodology_en":"Clearances and creepage distances","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odstępy izolacyjne powietrzne i powierzchniowe","reference":"PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | IEC 61439-4:2023 | IEC 61439-5:2014 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012","norm_bases":["PN-EN IEC 61439-1:2021-10","IEC 61439-1:2020","PN-EN IEC 61439-2:2021-10","IEC 61439-2:2020","PN-EN IEC 61439-3:2025-09","IEC 61439-3:2024","PN-EN 61439-4:2013-06","IEC 61439-4:2023","IEC 61439-5:2014","PN-EN IEC 61439-5:2024-04","IEC 61439-5:2023","PN-EN 61439-6:2013-03","IEC 61439-6:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rozdzielnice i sterownice niskonapięciowe, Low-voltage switchgear Odstępy izolacyjne powietrzne i powierzchniowe PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | IEC 61439-4:2023 | IEC 61439-5:2014 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012 Rozdzielnice i sterownice niskonapieciowe, Low-voltage switchgear Odstepy izolacyjne powietrzne i powierzchniowe PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | IEC 61439-4:2023 | IEC 61439-5:2014 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012","categories":["construction"],"row_index":146,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Low-voltage switchgear and controlgear assemblies Clearances and creepage distances PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | IEC 61439-4:2023 | IEC 61439-5:2014 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012","methodology_zh":"电气间隙与爬电距离","search_zh":"电气间隙与爬电距离 PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | IEC 61439-4:2023 | IEC 61439-5:2014 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012"},{"_id":"6a5dc9adf1c10c8ce825accd","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Rozdzielnice i sterownice niskonapięciowe, Low-voltage switchgear","test_object_en":"Low-voltage switchgear and controlgear assemblies","methodology":"Trwałość znakowania","methodology_en":"Durability of marking","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Trwałość znakowania","reference":"PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | IEC 61439-4:2023 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012","norm_bases":["PN-EN IEC 61439-1:2021-10","IEC 61439-1:2020","PN-EN IEC 61439-2:2021-10","IEC 61439-2:2020","PN-EN IEC 61439-3:2025-09","IEC 61439-3:2024","PN-EN 61439-4:2013-06","IEC 61439-4:2023","PN-EN IEC 61439-5:2024-04","IEC 61439-5:2023","PN-EN 61439-6:2013-03","IEC 61439-6:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rozdzielnice i sterownice niskonapięciowe, Low-voltage switchgear Trwałość znakowania PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | IEC 61439-4:2023 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012 Rozdzielnice i sterownice niskonapieciowe, Low-voltage switchgear Trwalosc znakowania PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | IEC 61439-4:2023 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012","categories":["other"],"row_index":147,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Low-voltage switchgear and controlgear assemblies Durability of marking PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | IEC 61439-4:2023 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012","methodology_zh":"标识耐久性","search_zh":"标识耐久性 PN-EN IEC 61439-1:2021-10 | IEC 61439-1:2020 | PN-EN IEC 61439-2:2021-10 | IEC 61439-2:2020 | PN-EN IEC 61439-3:2025-09 | IEC 61439-3:2024 | PN-EN 61439-4:2013-06 | IEC 61439-4:2023 | PN-EN IEC 61439-5:2024-04 | IEC 61439-5:2023 | PN-EN 61439-6:2013-03 | IEC 61439-6:2012"},{"_id":"6a5dc9adf1c10c8ce825acce","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Wyłączniki niskiego napięcia, Low-voltage circuit breakers","test_object_en":"Low-voltage circuit breakers","methodology":"Wytrzymałość zwarciowa","methodology_en":"Short-circuit withstand strength","parameters":[{"name":"Zakres","range":"do 150 kA rms / 400 kA peak"}],"parameters_en":[{"name":"Range","range":"do 150 kA rms / 400 kA peak"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość zwarciowa\nZakres do 150 kA rms / 400 kA peak","reference":"PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020 | IEC 60947-2:2024 | PN-EN 60947-2:2018-01 | PN-EN 60947-2:2018-01/A1:2020-06 | IEC 60947-2:2024 Scope of accreditation No. AB 324","norm_bases":["PN-EN IEC 60947-1:2021-07","IEC 60947-1:2020","IEC 60947-2:2024","PN-EN 60947-2:2018-01","PN-EN 60947-2:2018-01/A1:2020-06","IEC 60947-2:2024 Scope of accreditation No. AB 324"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyłączniki niskiego napięcia, Low-voltage circuit breakers Wytrzymałość zwarciowa\nZakres do 150 kA rms / 400 kA peak PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020 | IEC 60947-2:2024 | PN-EN 60947-2:2018-01 | PN-EN 60947-2:2018-01/A1:2020-06 | IEC 60947-2:2024 Scope of accreditation No. AB 324 Wylaczniki niskiego napiecia, Low-voltage circuit breakers Wytrzymalosc zwarciowa\nZakres do 150 kA rms / 400 kA peak PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020 | IEC 60947-2:2024 | PN-EN 60947-2:2018-01 | PN-EN 60947-2:2018-01/A1:2020-06 | IEC 60947-2:2024 Scope of accreditation No. AB 324","categories":["other"],"row_index":148,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Low-voltage circuit breakers Short-circuit withstand strength Range PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020 | IEC 60947-2:2024 | PN-EN 60947-2:2018-01 | PN-EN 60947-2:2018-01/A1:2020-06 | IEC 60947-2:2024 Scope of accreditation No. AB 324","parameters_zh":[{"name":"范围","range":"do 150 kA rms / 400 kA peak"}],"search_zh":"低压断路器 Low-voltage circuit breakers 短路耐受强度 范围 PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020 | IEC 60947-2:2024 | PN-EN 60947-2:2018-01 | PN-EN 60947-2:2018-01/A1:2020-06 | IEC 60947-2:2024 Scope of accreditation No. AB 324","methodology_zh":"短路耐受强度","test_object_zh":"低压断路器 Low-voltage circuit breakers"},{"_id":"6a5dc9adf1c10c8ce825accf","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Wyłączniki niskiego napięcia, Low-voltage circuit breakers","test_object_en":"Low-voltage circuit breakers","methodology":"Graniczne przyrosty temperatury","methodology_en":"Temperature-rise limits","parameters":[{"name":"Zakres","range":"do 20 kA"},{"name":"Próby nagrzewania prądem długotrwałym"}],"parameters_en":[{"name":"Range","range":"do 20 kA"},{"name":"Temperature-rise tests with continuous current"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Graniczne przyrosty temperatury\nZakres:\nZakres do 20 kA\nPróby nagrzewania prądem długotrwałym","reference":"PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020 | IEC 60947-2:2024 | PN-EN 60947-2:2018-01 | PN-EN 60947-2:2018-01/A1:2020-06 | IEC 60947-2:2024 Scope of accreditation No. AB 324","norm_bases":["PN-EN IEC 60947-1:2021-07","IEC 60947-1:2020","IEC 60947-2:2024","PN-EN 60947-2:2018-01","PN-EN 60947-2:2018-01/A1:2020-06","IEC 60947-2:2024 Scope of accreditation No. AB 324"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyłączniki niskiego napięcia, Low-voltage circuit breakers Graniczne przyrosty temperatury\nZakres:\nZakres do 20 kA\nPróby nagrzewania prądem długotrwałym PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020 | IEC 60947-2:2024 | PN-EN 60947-2:2018-01 | PN-EN 60947-2:2018-01/A1:2020-06 | IEC 60947-2:2024 Scope of accreditation No. AB 324 Wylaczniki niskiego napiecia, Low-voltage circuit breakers Graniczne przyrosty temperatury\nZakres:\nZakres do 20 kA\nProby nagrzewania pradem dlugotrwalym PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020 | IEC 60947-2:2024 | PN-EN 60947-2:2018-01 | PN-EN 60947-2:2018-01/A1:2020-06 | IEC 60947-2:2024 Scope of accreditation No. AB 324","categories":["other"],"row_index":149,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Low-voltage circuit breakers Temperature-rise limits Range Temperature-rise tests with continuous current PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020 | IEC 60947-2:2024 | PN-EN 60947-2:2018-01 | PN-EN 60947-2:2018-01/A1:2020-06 | IEC 60947-2:2024 Scope of accreditation No. AB 324","parameters_zh":[{"name":"范围","range":"do 20 kA"},{"name":"长时间电流温升试验"}],"search_zh":"低压断路器 Low-voltage circuit breakers 温升限值 范围 长时间电流温升试验 PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020 | IEC 60947-2:2024 | PN-EN 60947-2:2018-01 | PN-EN 60947-2:2018-01/A1:2020-06 | IEC 60947-2:2024 Scope of accreditation No. AB 324","methodology_zh":"温升限值","test_object_zh":"低压断路器 Low-voltage circuit breakers"},{"_id":"6a5dc9adf1c10c8ce825acd0","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Rozłączniki, odłączniki, rozłączniki izolacyjne i zestawy łączników z bezpiecznikami topikowymi, niskiego napięcia, Low-voltage switches, disconnectors, switch-","test_object_en":"Low-voltage switches, disconnectors, switch-disconnectors and fuse-combination units","methodology":"Graniczne przyrosty temperatury","methodology_en":"Temperature-rise limits","parameters":[{"name":"Zakres","range":"do 20 kA"},{"name":"Próby nagrzewania prądem długotrwałym"}],"parameters_en":[{"name":"Range","range":"do 20 kA"},{"name":"Temperature-rise tests with continuous current"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Graniczne przyrosty temperatury\nZakres:\nZakres do 20 kA\nPróby nagrzewania prądem długotrwałym","reference":"PN-EN IEC 60947-1:2021-07 | PN-EN IEC 60947-3:2021-07/AC:2022-01 | IEC 60947-3:2020/AMD1:2025 | IEC 60947-1:2020 | PN-EN IEC 60947-3:2021-07 | IEC 60947-3:2020 | PN-EN 60269-1:2010 | IEC 60269-1:2024 | PN-EN 60269-1:2010/A1:2012 | PN-EN 60269-1:2010/A2:2015-02","norm_bases":["PN-EN IEC 60947-1:2021-07","PN-EN IEC 60947-3:2021-07/AC:2022-01","IEC 60947-3:2020/AMD1:2025","IEC 60947-1:2020","PN-EN IEC 60947-3:2021-07","IEC 60947-3:2020","PN-EN 60269-1:2010","IEC 60269-1:2024","PN-EN 60269-1:2010/A1:2012","PN-EN 60269-1:2010/A2:2015-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rozłączniki, odłączniki, rozłączniki izolacyjne i zestawy łączników z bezpiecznikami topikowymi, niskiego napięcia, Low-voltage switches, disconnectors, switch- Graniczne przyrosty temperatury\nZakres:\nZakres do 20 kA\nPróby nagrzewania prądem długotrwałym PN-EN IEC 60947-1:2021-07 | PN-EN IEC 60947-3:2021-07/AC:2022-01 | IEC 60947-3:2020/AMD1:2025 | IEC 60947-1:2020 | PN-EN IEC 60947-3:2021-07 | IEC 60947-3:2020 | PN-EN 60269-1:2010 | IEC 60269-1:2024 | PN-EN 60269-1:2010/A1:2012 | PN-EN 60269-1:2010/A2:2015-02 Rozlaczniki, odlaczniki, rozlaczniki izolacyjne i zestawy lacznikow z bezpiecznikami topikowymi, niskiego napiecia, Low-voltage switches, disconnectors, switch- Graniczne przyrosty temperatury\nZakres:\nZakres do 20 kA\nProby nagrzewania pradem dlugotrwalym PN-EN IEC 60947-1:2021-07 | PN-EN IEC 60947-3:2021-07/AC:2022-01 | IEC 60947-3:2020/AMD1:2025 | IEC 60947-1:2020 | PN-EN IEC 60947-3:2021-07 | IEC 60947-3:2020 | PN-EN 60269-1:2010 | IEC 60269-1:2024 | PN-EN 60269-1:2010/A1:2012 | PN-EN 60269-1:2010/A2:2015-02","categories":["construction"],"row_index":150,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Low-voltage switches, disconnectors, switch-disconnectors and fuse-combination units Temperature-rise limits Range Temperature-rise tests with continuous current PN-EN IEC 60947-1:2021-07 | PN-EN IEC 60947-3:2021-07/AC:2022-01 | IEC 60947-3:2020/AMD1:2025 | IEC 60947-1:2020 | PN-EN IEC 60947-3:2021-07 | IEC 60947-3:2020 | PN-EN 60269-1:2010 | IEC 60269-1:2024 | PN-EN 60269-1:2010/A1:2012 | PN-EN 60269-1:2010/A2:2015-02","parameters_zh":[{"name":"范围","range":"do 20 kA"},{"name":"长时间电流温升试验"}],"search_zh":"低压负荷开关、隔离开关、隔离用开关及开关熔断器组合电器 Low-voltage switches, disconnectors, switch- 温升限值 范围 长时间电流温升试验 PN-EN IEC 60947-1:2021-07 | PN-EN IEC 60947-3:2021-07/AC:2022-01 | IEC 60947-3:2020/AMD1:2025 | IEC 60947-1:2020 | PN-EN IEC 60947-3:2021-07 | IEC 60947-3:2020 | PN-EN 60269-1:2010 | IEC 60269-1:2024 | PN-EN 60269-1:2010/A1:2012 | PN-EN 60269-1:2010/A2:2015-02","methodology_zh":"温升限值","test_object_zh":"低压负荷开关、隔离开关、隔离用开关及开关熔断器组合电器 Low-voltage switches, disconnectors, switch-"},{"_id":"6a5dc9adf1c10c8ce825acd1","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Rozłączniki, odłączniki, rozłączniki izolacyjne i zestawy łączników z bezpiecznikami topikowymi, niskiego napięcia, Low-voltage switches, disconnectors, switch-","test_object_en":"Low-voltage switches, disconnectors, switch-disconnectors and fuse-combination units","methodology":"Wytrzymałość zwarciowa","methodology_en":"Short-circuit withstand strength","parameters":[{"name":"Zakres","range":"do 150 kA rms / 400 kA peak"}],"parameters_en":[{"name":"Range","range":"do 150 kA rms / 400 kA peak"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość zwarciowa\nZakres do 150 kA rms / 400 kA peak","reference":"PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020 | PN-EN 60269-1:2010 | PN-EN 60269-1:2010/A1:2012 | PN-EN 60269-1:2010/A2:2015-02 | IEC 60269-1:2024 | IEC 60269-2:2013/AMD2:2024","norm_bases":["PN-EN IEC 60947-1:2021-07","IEC 60947-1:2020","PN-EN 60269-1:2010","PN-EN 60269-1:2010/A1:2012","PN-EN 60269-1:2010/A2:2015-02","IEC 60269-1:2024","IEC 60269-2:2013/AMD2:2024"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rozłączniki, odłączniki, rozłączniki izolacyjne i zestawy łączników z bezpiecznikami topikowymi, niskiego napięcia, Low-voltage switches, disconnectors, switch- Wytrzymałość zwarciowa\nZakres do 150 kA rms / 400 kA peak PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020 | PN-EN 60269-1:2010 | PN-EN 60269-1:2010/A1:2012 | PN-EN 60269-1:2010/A2:2015-02 | IEC 60269-1:2024 | IEC 60269-2:2013/AMD2:2024 Rozlaczniki, odlaczniki, rozlaczniki izolacyjne i zestawy lacznikow z bezpiecznikami topikowymi, niskiego napiecia, Low-voltage switches, disconnectors, switch- Wytrzymalosc zwarciowa\nZakres do 150 kA rms / 400 kA peak PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020 | PN-EN 60269-1:2010 | PN-EN 60269-1:2010/A1:2012 | PN-EN 60269-1:2010/A2:2015-02 | IEC 60269-1:2024 | IEC 60269-2:2013/AMD2:2024","categories":["construction"],"row_index":151,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Low-voltage switches, disconnectors, switch-disconnectors and fuse-combination units Short-circuit withstand strength Range PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020 | PN-EN 60269-1:2010 | PN-EN 60269-1:2010/A1:2012 | PN-EN 60269-1:2010/A2:2015-02 | IEC 60269-1:2024 | IEC 60269-2:2013/AMD2:2024","parameters_zh":[{"name":"范围","range":"do 150 kA rms / 400 kA peak"}],"search_zh":"低压负荷开关、隔离开关、隔离用开关及开关熔断器组合电器 Low-voltage switches, disconnectors, switch- 短路耐受强度 范围 PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020 | PN-EN 60269-1:2010 | PN-EN 60269-1:2010/A1:2012 | PN-EN 60269-1:2010/A2:2015-02 | IEC 60269-1:2024 | IEC 60269-2:2013/AMD2:2024","methodology_zh":"短路耐受强度","test_object_zh":"低压负荷开关、隔离开关、隔离用开关及开关熔断器组合电器 Low-voltage switches, disconnectors, switch-"},{"_id":"6a5dc9adf1c10c8ce825acd2","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Osłonięte rozdzielnice niskiego napięcia, Enclosed low-voltage","test_object_en":"Enclosed low-voltage switchgear","methodology":"Odporność na działanie łuku elektrycznego","methodology_en":"Resistance to electric arc","parameters":[{"name":"Zakres","range":"do 150 kA rms / 400 kA peak"},{"name":"Próby w warunkach wewnętrznego zwarcia łukowego"}],"parameters_en":[{"name":"Range","range":"do 150 kA rms / 400 kA peak"},{"name":"Tests under internal arc fault conditions"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na działanie łuku elektrycznego\nZakres:\nZakres do 150 kA rms / 400 kA peak\nPróby w warunkach wewnętrznego zwarcia łukowego","reference":"PN-E-05163:2002 IEC/ TR 61641:2014","norm_bases":["PN-E-05163:2002 IEC/ TR 61641:2014"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osłonięte rozdzielnice niskiego napięcia, Enclosed low-voltage Odporność na działanie łuku elektrycznego\nZakres:\nZakres do 150 kA rms / 400 kA peak\nPróby w warunkach wewnętrznego zwarcia łukowego PN-E-05163:2002 IEC/ TR 61641:2014 Osloniete rozdzielnice niskiego napiecia, Enclosed low-voltage Odpornosc na dzialanie luku elektrycznego\nZakres:\nZakres do 150 kA rms / 400 kA peak\nProby w warunkach wewnetrznego zwarcia lukowego PN-E-05163:2002 IEC/ TR 61641:2014","categories":["other"],"row_index":152,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Enclosed low-voltage switchgear Resistance to electric arc Range Tests under internal arc fault conditions PN-E-05163:2002 IEC/ TR 61641:2014","parameters_zh":[{"name":"范围","range":"do 150 kA rms / 400 kA peak"},{"name":"Próby w warunkach wewnętrznego zwarcia łukowego"}],"search_zh":"耐电弧作用性 范围 PN-E-05163:2002 IEC/ TR 61641:2014","methodology_zh":"耐电弧作用性"},{"_id":"6a5dc9adf1c10c8ce825acd3","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Bezpieczniki topikowe niskonapięciowe na prąd znamionowy do 1250 A","test_object_en":"Low-voltage fuses for rated current up to 1250 A","methodology":"Graniczne przyrosty temperatury","methodology_en":"Temperature-rise limits","parameters":[{"name":"Zakres","range":"do 20 kA"},{"name":"Próby nagrzewania prądem długotrwałym, pomiar strat mocy"}],"parameters_en":[{"name":"Range","range":"do 20 kA"},{"name":"Temperature-rise tests with continuous current, measurement of power losses"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Graniczne przyrosty temperatury\nZakres:\nZakres do 20 kA\nPróby nagrzewania prądem długotrwałym, pomiar strat mocy","reference":"PN-EN 60269-1:2010 | PN-EN 60269-1:2010/A1:2012 | PN-EN 60269-1:2010/A2:2015-02 | IEC 60269-1:2024 | IEC 60269-2:2013/AMD2:2024 | PN-HD 60269-2:2014-06 | IEC 60269-2:2013 | IEC 60269-2:2013/AMD1:2016","norm_bases":["PN-EN 60269-1:2010","PN-EN 60269-1:2010/A1:2012","PN-EN 60269-1:2010/A2:2015-02","IEC 60269-1:2024","IEC 60269-2:2013/AMD2:2024","PN-HD 60269-2:2014-06","IEC 60269-2:2013","IEC 60269-2:2013/AMD1:2016"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Bezpieczniki topikowe niskonapięciowe na prąd znamionowy do 1250 A Graniczne przyrosty temperatury\nZakres:\nZakres do 20 kA\nPróby nagrzewania prądem długotrwałym, pomiar strat mocy PN-EN 60269-1:2010 | PN-EN 60269-1:2010/A1:2012 | PN-EN 60269-1:2010/A2:2015-02 | IEC 60269-1:2024 | IEC 60269-2:2013/AMD2:2024 | PN-HD 60269-2:2014-06 | IEC 60269-2:2013 | IEC 60269-2:2013/AMD1:2016 Bezpieczniki topikowe niskonapieciowe na prad znamionowy do 1250 A Graniczne przyrosty temperatury\nZakres:\nZakres do 20 kA\nProby nagrzewania pradem dlugotrwalym, pomiar strat mocy PN-EN 60269-1:2010 | PN-EN 60269-1:2010/A1:2012 | PN-EN 60269-1:2010/A2:2015-02 | IEC 60269-1:2024 | IEC 60269-2:2013/AMD2:2024 | PN-HD 60269-2:2014-06 | IEC 60269-2:2013 | IEC 60269-2:2013/AMD1:2016","categories":["other"],"row_index":153,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Low-voltage fuses for rated current up to 1250 A Temperature-rise limits Range Temperature-rise tests with continuous current, measurement of power losses PN-EN 60269-1:2010 | PN-EN 60269-1:2010/A1:2012 | PN-EN 60269-1:2010/A2:2015-02 | IEC 60269-1:2024 | IEC 60269-2:2013/AMD2:2024 | PN-HD 60269-2:2014-06 | IEC 60269-2:2013 | IEC 60269-2:2013/AMD1:2016","parameters_zh":[{"name":"范围","range":"do 20 kA"},{"name":"Próby nagrzewania prądem długotrwałym, pomiar strat mocy"}],"search_zh":"温升限值 范围 PN-EN 60269-1:2010 | PN-EN 60269-1:2010/A1:2012 | PN-EN 60269-1:2010/A2:2015-02 | IEC 60269-1:2024 | IEC 60269-2:2013/AMD2:2024 | PN-HD 60269-2:2014-06 | IEC 60269-2:2013 | IEC 60269-2:2013/AMD1:2016","methodology_zh":"温升限值"},{"_id":"6a5dc9adf1c10c8ce825acd4","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Bezpieczniki topikowe niskonapięciowe na prąd znamionowy do 1250 A","test_object_en":"Low-voltage fuses for rated current up to 1250 A","methodology":"Prądy zadziałania","methodology_en":"Operating currents","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Prądy zadziałania","reference":"PN-EN 60269-1:2010 | PN-EN 60269-1:2010/A1:2012 | PN-EN 60269-1:2010/A2:2015-02 | IEC 60269-1:2024","norm_bases":["PN-EN 60269-1:2010","PN-EN 60269-1:2010/A1:2012","PN-EN 60269-1:2010/A2:2015-02","IEC 60269-1:2024"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Bezpieczniki topikowe niskonapięciowe na prąd znamionowy do 1250 A Prądy zadziałania PN-EN 60269-1:2010 | PN-EN 60269-1:2010/A1:2012 | PN-EN 60269-1:2010/A2:2015-02 | IEC 60269-1:2024 Bezpieczniki topikowe niskonapieciowe na prad znamionowy do 1250 A Prady zadzialania PN-EN 60269-1:2010 | PN-EN 60269-1:2010/A1:2012 | PN-EN 60269-1:2010/A2:2015-02 | IEC 60269-1:2024","categories":["other"],"row_index":154,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Low-voltage fuses for rated current up to 1250 A Operating currents PN-EN 60269-1:2010 | PN-EN 60269-1:2010/A1:2012 | PN-EN 60269-1:2010/A2:2015-02 | IEC 60269-1:2024"},{"_id":"6a5dc9adf1c10c8ce825acd5","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Bezpieczniki topikowe niskonapięciowe na prąd znamionowy do 1250 A","test_object_en":"Low-voltage fuses for rated current up to 1250 A","methodology":"Trwałość styków","methodology_en":"Durability of contacts","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Trwałość styków","reference":"PN-EN 60269-1:2010 | PN-EN 60269-1:2010/A1:2012 | PN-EN 60269-1:2010/A2:2015-02 | IEC 60269-1:2024","norm_bases":["PN-EN 60269-1:2010","PN-EN 60269-1:2010/A1:2012","PN-EN 60269-1:2010/A2:2015-02","IEC 60269-1:2024"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Bezpieczniki topikowe niskonapięciowe na prąd znamionowy do 1250 A Trwałość styków PN-EN 60269-1:2010 | PN-EN 60269-1:2010/A1:2012 | PN-EN 60269-1:2010/A2:2015-02 | IEC 60269-1:2024 Bezpieczniki topikowe niskonapieciowe na prad znamionowy do 1250 A Trwalosc stykow PN-EN 60269-1:2010 | PN-EN 60269-1:2010/A1:2012 | PN-EN 60269-1:2010/A2:2015-02 | IEC 60269-1:2024","categories":["other"],"row_index":155,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Low-voltage fuses for rated current up to 1250 A Durability of contacts PN-EN 60269-1:2010 | PN-EN 60269-1:2010/A1:2012 | PN-EN 60269-1:2010/A2:2015-02 | IEC 60269-1:2024"},{"_id":"6a5dc9adf1c10c8ce825acd6","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Wkładki bezpiecznikowe wysokiego napięcia do zabezpieczania obwodów silników","test_object_en":"High-voltage fuse-links for motor circuit protection","methodology":"Odporność","methodology_en":"Resistance","parameters":[{"name":"Zakres","range":"do 20 kA"},{"name":"Wytrzymałość na cykliczne zmiany prądu impulsowego Withstand"}],"parameters_en":[{"name":"Range","range":"do 20 kA"},{"name":"Resistance to cyclic changes of impulse current Withstand"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność\nZakres:\nZakres do 20 kA\nWytrzymałość na cykliczne zmiany prądu impulsowego Withstand","reference":"PN-EN 60644:2010 | IEC 60644:2009 | IEC 60644:2009/AMD1:2019 Scope of accreditation No. AB 324","norm_bases":["PN-EN 60644:2010","IEC 60644:2009","IEC 60644:2009/AMD1:2019 Scope of accreditation No. AB 324"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wkładki bezpiecznikowe wysokiego napięcia do zabezpieczania obwodów silników Odporność\nZakres:\nZakres do 20 kA\nWytrzymałość na cykliczne zmiany prądu impulsowego Withstand PN-EN 60644:2010 | IEC 60644:2009 | IEC 60644:2009/AMD1:2019 Scope of accreditation No. AB 324 Wkladki bezpiecznikowe wysokiego napiecia do zabezpieczania obwodow silnikow Odpornosc\nZakres:\nZakres do 20 kA\nWytrzymalosc na cykliczne zmiany pradu impulsowego Withstand PN-EN 60644:2010 | IEC 60644:2009 | IEC 60644:2009/AMD1:2019 Scope of accreditation No. AB 324","categories":["other"],"row_index":156,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"High-voltage fuse-links for motor circuit protection Resistance Range Resistance to cyclic changes of impulse current Withstand PN-EN 60644:2010 | IEC 60644:2009 | IEC 60644:2009/AMD1:2019 Scope of accreditation No. AB 324","parameters_zh":[{"name":"范围","range":"do 20 kA"},{"name":"Wytrzymałość na cykliczne zmiany prądu impulsowego Withstand"}],"search_zh":"抗力 范围 PN-EN 60644:2010 | IEC 60644:2009 | IEC 60644:2009/AMD1:2019 Scope of accreditation No. AB 324","methodology_zh":"抗力"},{"_id":"6a5dc9adf1c10c8ce825acd7","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Puste obudowy do rozdzielnic i sterownic niskiego napięcia","test_object_en":"Empty enclosures for low-voltage switchgear and controlgear assemblies","methodology":"Trwałość znakowania","methodology_en":"Durability of marking","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Trwałość znakowania","reference":"PN-EN IEC 62208:2024-04 | IEC 62208:2023","norm_bases":["PN-EN IEC 62208:2024-04","IEC 62208:2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Puste obudowy do rozdzielnic i sterownic niskiego napięcia Trwałość znakowania PN-EN IEC 62208:2024-04 | IEC 62208:2023 Puste obudowy do rozdzielnic i sterownic niskiego napiecia Trwalosc znakowania PN-EN IEC 62208:2024-04 | IEC 62208:2023","categories":["other"],"row_index":157,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Empty enclosures for low-voltage switchgear and controlgear assemblies Durability of marking PN-EN IEC 62208:2024-04 | IEC 62208:2023","methodology_zh":"标识耐久性","search_zh":"低压成套开关设备与控制设备用空外壳 标识耐久性 PN-EN IEC 62208:2024-04 | IEC 62208:2023","test_object_zh":"低压成套开关设备与控制设备用空外壳"},{"_id":"6a5dc9adf1c10c8ce825acd8","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Puste obudowy do rozdzielnic i sterownic niskiego napięcia","test_object_en":"Empty enclosures for low-voltage switchgear and controlgear assemblies","methodology":"Obciążenie statyczne (z wyjątkiem obudów z materiałów izolacyjnych)","methodology_en":"Static load (except enclosures made of insulating materials)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Obciążenie statyczne (z wyjątkiem obudów z materiałów izolacyjnych)","reference":"PN-EN IEC 62208:2024-04 | IEC 62208:2023","norm_bases":["PN-EN IEC 62208:2024-04","IEC 62208:2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Puste obudowy do rozdzielnic i sterownic niskiego napięcia Obciążenie statyczne (z wyjątkiem obudów z materiałów izolacyjnych) PN-EN IEC 62208:2024-04 | IEC 62208:2023 Puste obudowy do rozdzielnic i sterownic niskiego napiecia Obciazenie statyczne (z wyjatkiem obudow z materialow izolacyjnych) PN-EN IEC 62208:2024-04 | IEC 62208:2023","categories":["materials","construction"],"row_index":158,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Empty enclosures for low-voltage switchgear and controlgear assemblies Static load (except enclosures made of insulating materials) PN-EN IEC 62208:2024-04 | IEC 62208:2023","search_zh":"低压成套开关设备与控制设备用空外壳 PN-EN IEC 62208:2024-04 | IEC 62208:2023","test_object_zh":"低压成套开关设备与控制设备用空外壳"},{"_id":"6a5dc9adf1c10c8ce825acd9","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Puste obudowy do rozdzielnic i sterownic niskiego napięcia","test_object_en":"Empty enclosures for low-voltage switchgear and controlgear assemblies","methodology":"Podnoszenie, Lifting","methodology_en":"Lifting, Lifting","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Podnoszenie, Lifting","reference":"PN-EN IEC 62208:2024-04 | IEC 62208:2023","norm_bases":["PN-EN IEC 62208:2024-04","IEC 62208:2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Puste obudowy do rozdzielnic i sterownic niskiego napięcia Podnoszenie, Lifting PN-EN IEC 62208:2024-04 | IEC 62208:2023 Puste obudowy do rozdzielnic i sterownic niskiego napiecia Podnoszenie, Lifting PN-EN IEC 62208:2024-04 | IEC 62208:2023","categories":["other"],"row_index":159,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Empty enclosures for low-voltage switchgear and controlgear assemblies Lifting, Lifting PN-EN IEC 62208:2024-04 | IEC 62208:2023","search_zh":"低压成套开关设备与控制设备用空外壳 PN-EN IEC 62208:2024-04 | IEC 62208:2023","test_object_zh":"低压成套开关设备与控制设备用空外壳"},{"_id":"6a5dc9adf1c10c8ce825acda","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Puste obudowy do rozdzielnic i sterownic niskiego napięcia","test_object_en":"Empty enclosures for low-voltage switchgear and controlgear assemblies","methodology":"Poosiowe obciążenie metalowych zaprasek","methodology_en":"Axial load of metal crimps","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Poosiowe obciążenie metalowych zaprasek","reference":"PN-EN IEC 62208:2024-04 | IEC 62208:2023","norm_bases":["PN-EN IEC 62208:2024-04","IEC 62208:2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Puste obudowy do rozdzielnic i sterownic niskiego napięcia Poosiowe obciążenie metalowych zaprasek PN-EN IEC 62208:2024-04 | IEC 62208:2023 Puste obudowy do rozdzielnic i sterownic niskiego napiecia Poosiowe obciazenie metalowych zaprasek PN-EN IEC 62208:2024-04 | IEC 62208:2023","categories":["materials"],"row_index":160,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Empty enclosures for low-voltage switchgear and controlgear assemblies Axial load of metal crimps PN-EN IEC 62208:2024-04 | IEC 62208:2023","search_zh":"低压成套开关设备与控制设备用空外壳 PN-EN IEC 62208:2024-04 | IEC 62208:2023","test_object_zh":"低压成套开关设备与控制设备用空外壳"},{"_id":"6a5dc9adf1c10c8ce825acdb","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Puste obudowy do rozdzielnic i sterownic niskiego napięcia","test_object_en":"Empty enclosures for low-voltage switchgear and controlgear assemblies","methodology":"Ciągłości obwodu ochronnego","methodology_en":"Continuity of the protective circuit","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Ciągłości obwodu ochronnego","reference":"PN-EN IEC 62208:2024-04 | IEC 62208:2023","norm_bases":["PN-EN IEC 62208:2024-04","IEC 62208:2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Puste obudowy do rozdzielnic i sterownic niskiego napięcia Ciągłości obwodu ochronnego PN-EN IEC 62208:2024-04 | IEC 62208:2023 Puste obudowy do rozdzielnic i sterownic niskiego napiecia Ciaglosci obwodu ochronnego PN-EN IEC 62208:2024-04 | IEC 62208:2023","categories":["other"],"row_index":161,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Empty enclosures for low-voltage switchgear and controlgear assemblies Continuity of the protective circuit PN-EN IEC 62208:2024-04 | IEC 62208:2023","search_zh":"低压成套开关设备与控制设备用空外壳 PN-EN IEC 62208:2024-04 | IEC 62208:2023","test_object_zh":"低压成套开关设备与控制设备用空外壳"},{"_id":"6a5dc9adf1c10c8ce825acdc","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Urządzenia elektryczne, Electrical equipment","test_object_en":"Electrical equipment","methodology":"Stopień ochrony, Zakres do IP45","methodology_en":"Degree of protection, Range up to IP45","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stopień ochrony, Zakres do IP45","reference":"PN-EN 60529:2003 | PN-EN 60529:2003/AC:2017-12 | PN-EN 60529:2003/A2:2014-07 | IEC 60529:1989/AMD1:1999/A2:2013 | IEC 60529:1989/AMD1:1999 | IEC 60529:1989/AMD2:2013","norm_bases":["PN-EN 60529:2003","PN-EN 60529:2003/AC:2017-12","PN-EN 60529:2003/A2:2014-07","IEC 60529:1989/AMD1:1999/A2:2013","IEC 60529:1989/AMD1:1999","IEC 60529:1989/AMD2:2013"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne, Electrical equipment Stopień ochrony, Zakres do IP45 PN-EN 60529:2003 | PN-EN 60529:2003/AC:2017-12 | PN-EN 60529:2003/A2:2014-07 | IEC 60529:1989/AMD1:1999/A2:2013 | IEC 60529:1989/AMD1:1999 | IEC 60529:1989/AMD2:2013 Urzadzenia elektryczne, Electrical equipment Stopien ochrony, Zakres do IP45 PN-EN 60529:2003 | PN-EN 60529:2003/AC:2017-12 | PN-EN 60529:2003/A2:2014-07 | IEC 60529:1989/AMD1:1999/A2:2013 | IEC 60529:1989/AMD1:1999 | IEC 60529:1989/AMD2:2013","categories":["other"],"row_index":162,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical equipment Degree of protection, Range up to IP45 PN-EN 60529:2003 | PN-EN 60529:2003/AC:2017-12 | PN-EN 60529:2003/A2:2014-07 | IEC 60529:1989/AMD1:1999/A2:2013 | IEC 60529:1989/AMD1:1999 | IEC 60529:1989/AMD2:2013"},{"_id":"6a5dc9adf1c10c8ce825acdd","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Urządzenia elektryczne, Electrical equipment","test_object_en":"Electrical equipment","methodology":"Stopień ochrony przed zewnętrznymi uderzeniami mechanicznymi","methodology_en":"Degree of protection against external mechanical impacts","parameters":[{"name":"Sprawdzenie kodu IK07, IK09 i IK10"}],"parameters_en":[{"name":"Verification of code IK07, IK09 and IK10"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stopień ochrony przed zewnętrznymi uderzeniami mechanicznymi\nSprawdzenie kodu IK07, IK09 i IK10","reference":"PN-EN 62262:2003 | PN-EN 62262:2003/A1:2022-06 | IEC 62262:2002 | IEC 62262:2002/AMD1:2021","norm_bases":["PN-EN 62262:2003","PN-EN 62262:2003/A1:2022-06","IEC 62262:2002","IEC 62262:2002/AMD1:2021"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia elektryczne, Electrical equipment Stopień ochrony przed zewnętrznymi uderzeniami mechanicznymi\nSprawdzenie kodu IK07, IK09 i IK10 PN-EN 62262:2003 | PN-EN 62262:2003/A1:2022-06 | IEC 62262:2002 | IEC 62262:2002/AMD1:2021 Urzadzenia elektryczne, Electrical equipment Stopien ochrony przed zewnetrznymi uderzeniami mechanicznymi\nSprawdzenie kodu IK07, IK09 i IK10 PN-EN 62262:2003 | PN-EN 62262:2003/A1:2022-06 | IEC 62262:2002 | IEC 62262:2002/AMD1:2021","categories":["other"],"row_index":163,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical equipment Degree of protection against external mechanical impacts Verification of code IK07, IK09 and IK10 PN-EN 62262:2003 | PN-EN 62262:2003/A1:2022-06 | IEC 62262:2002 | IEC 62262:2002/AMD1:2021"},{"_id":"6a5dc9adf1c10c8ce825acde","lab_id":"69ad52a3de79e566650fb1bd","country":"PL","accr_number":"AB 324","accr_body":"PCA","test_object":"Kable elektroenergetyczne","test_object_en":"Power cables","methodology":"Wytrzymałość zwarciowa do 150 kA rms","methodology_en":"Short-circuit withstand up to 150 kA rms","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość zwarciowa do 150 kA rms","reference":"PN-HD 605 S2:2008","norm_bases":["PN-HD 605 S2:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable elektroenergetyczne Wytrzymałość zwarciowa do 150 kA rms PN-HD 605 S2:2008 Kable elektroenergetyczne Wytrzymalosc zwarciowa do 150 kA rms PN-HD 605 S2:2008","categories":["other"],"row_index":164,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Power cables Short-circuit withstand up to 150 kA rms PN-HD 605 S2:2008"}],"has_pdf":true}