{"lab":{"_id":"69ad52a3de79e566650fb1bb","accr_number":"AB 322","country":"PL","accr_body":"PCA","address":"ul. Chmielna 132/134, 00-805 Warszawa, CENTRALNE LABORATORIUM BADAWCZE, ODDZIAŁ W WARSZAWIE, ul. Bartycka 110 A","categories":["water","environment","materials"],"city":"Warszawa","imported_at":"2026-03-08T10:42:43.265Z","methods_count":169,"name":"GŁÓWNY INSPEKTORAT OCHRONY ŚRODOWISKA","parse_status":"parsed","parse_version":3,"pdf_files":["AB_322.pdf"],"scope_summary":"","search_text":"główny inspektorat ochrony środowiska ul. chmielna 132/134, 00-805 warszawa, centralne laboratorium badawcze, oddział w warszawie, ul. bartycka 110 a water other pharma electronics environment materials metrology food petro automotive","status":"active","updated_at":"2026-03-08T14:51:10.194Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:10.194Z","location":{"type":"Point","coordinates":[21.0122,52.2297]},"email_confidence":"high","email_mx":true,"email_source":"https://www.gov.pl/web/gios/centralne-laboratorium-badawcze","fields_of_testing":[{"codes":"B/28; B/30","pl":"Badania biologiczne próbek wody, ścieków","en":"Biological tests of water, sewage."},{"codes":"B/32/P","pl":"Badania biologiczne i pobieranie próbek osadów","en":"Biological and sampling of sediments"},{"codes":"C/28/P; C/30/P; C/31/P; C/32/P; C/36/P","pl":"Badania chemiczne i pobieranie próbek wody, ścieków, gleby, osadów, odpadów, gazów odlotowych","en":"Chemical tests and sampling of water, sewage, soil, sediments, waste, waste gases"},{"codes":"C/9/P","pl":"Badania chemiczne i pobieranie próbek – powietrze (czynniki szkodliwe pyłów)","en":"Chemical tests and sampling – air (harmful factors dust)"},{"codes":"G/34","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko ogólne (czynniki fizyczne – hałas, pole elektromagnetyczne)","en":"Tests concerning environmental engineering (environmental and climatic) – general environment (physical factors – noise, electromagnetic field)"},{"codes":"G/36","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – gazy odlotowe","en":"Tests concerning environmental engineering (environmental and climatic) – waste gases"},{"codes":"N/28/P; N/30/P; N/31/P; N/32/P; N/36/P","pl":"Badania właściwości fizycznych i pobieranie próbek: wody, ścieków, odpadów, gleby, osadów, gazów odlotowych","en":"Tests of physical properties and sampling of water, sewage, soil, sediments, waste gases"},{"codes":"P/36; P/28","pl":"Pobieranie próbek gazów odlotowych, wody","en":"Sampling of waste gases, water"}],"issue":{"no":"29","date":"17.11.2025"},"parse_date":"2026-07-20T07:09:33.572Z","parse_source":"script-pdfplumber","map_coord":[52.227738,20.992749],"map_geo":"nominatim-street","has_en":true,"category_counts":{"water":111,"environment":42,"other":19,"materials":6,"petro":4,"food":1},"category_scores":{"water":67.33,"environment":9.64,"other":1.97,"materials":0.2,"petro":0.09,"food":0.01},"has_zh":true},"methods":[{"_id":"6a5dc9adf1c10c8ce825ab91","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Pobieranie próbek do badań chemicznych, biologicznych i fizycznych Temperatura ścieków / pobranej próbki","methodology_en":"Sampling for chemical, biological and physical testing Temperature of wastewater / of the sample taken","parameters":[{"name":"ścieków"},{"name":"Zakres","range":"(1,0 – 50) oC"}],"parameters_en":[{"name":"wastewater"},{"name":"Range","range":"(1,0 – 50) oC"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych, biologicznych i fizycznych Temperatura ścieków / pobranej próbki\nZakres:\nścieków\nZakres (1,0 – 50) oC","reference":"PN-ISO 5667-10:2021-11 | PN-77/C-04584","norm_bases":["PN-ISO 5667-10:2021-11","PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Pobieranie próbek do badań chemicznych, biologicznych i fizycznych Temperatura ścieków / pobranej próbki\nZakres:\nścieków\nZakres (1,0 – 50) oC PN-ISO 5667-10:2021-11 | PN-77/C-04584 Scieki Pobieranie probek do badan chemicznych, biologicznych i fizycznych Temperatura sciekow / pobranej probki\nZakres:\nsciekow\nZakres (1,0 – 50) oC PN-ISO 5667-10:2021-11 | PN-77/C-04584","categories":["water"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Sampling for chemical, biological and physical testing Temperature of wastewater / of the sample taken wastewater Range PN-ISO 5667-10:2021-11 | PN-77/C-04584","parameters_zh":[{"name":"ścieków"},{"name":"范围","range":"(1,0 – 50) oC"}],"search_zh":"污水 范围 PN-ISO 5667-10:2021-11 | PN-77/C-04584","test_object_zh":"污水"},{"_id":"6a5dc9adf1c10c8ce825ab92","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda podziemna","test_object_en":"Groundwater","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura wody/pobranej próbki wody","methodology_en":"Sampling for chemical and physical testing Temperature of water/of the water sample taken","parameters":[{"name":"Zakres","range":"(1,0 – 50) oC"}],"parameters_en":[{"name":"Range","range":"(1,0 – 50) oC"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura wody/pobranej próbki wody\nZakres (1,0 – 50) oC","reference":"PN-ISO 5667-11:2017-10 | PN-77/C-04584","norm_bases":["PN-ISO 5667-11:2017-10","PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda podziemna Pobieranie próbek do badań chemicznych i fizycznych Temperatura wody/pobranej próbki wody\nZakres (1,0 – 50) oC PN-ISO 5667-11:2017-10 | PN-77/C-04584 Woda podziemna Pobieranie probek do badan chemicznych i fizycznych Temperatura wody/pobranej probki wody\nZakres (1,0 – 50) oC PN-ISO 5667-11:2017-10 | PN-77/C-04584","categories":["water"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Groundwater Sampling for chemical and physical testing Temperature of water/of the water sample taken Range PN-ISO 5667-11:2017-10 | PN-77/C-04584","parameters_zh":[{"name":"范围","range":"(1,0 – 50) oC"}],"search_zh":"地下水 用于化学与物理检验的采样 水/所采水样的温度 范围 PN-ISO 5667-11:2017-10 | PN-77/C-04584","test_object_zh":"地下水","methodology_zh":"用于化学与物理检验的采样 水/所采水样的温度"},{"_id":"6a5dc9adf1c10c8ce825ab93","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura wody / pobranej próbki wody","methodology_en":"Sampling for chemical and physical testing Temperature of water / of the water sample taken","parameters":[{"name":"Zakres","range":"(1,0 – 50) oC"}],"parameters_en":[{"name":"Range","range":"(1,0 – 50) oC"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura wody / pobranej próbki wody\nZakres (1,0 – 50) oC","reference":"PN-EN ISO 5667-6:2016-12 z wył. pkt 7.5, 7.6 | PN-77/C-04584","norm_bases":["PN-EN ISO 5667-6:2016-12 z wył. pkt 7.5, 7.6","PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych Temperatura wody / pobranej próbki wody\nZakres (1,0 – 50) oC PN-EN ISO 5667-6:2016-12 z wył. pkt 7.5, 7.6 | PN-77/C-04584 Woda Pobieranie probek do badan chemicznych i fizycznych Temperatura wody / pobranej probki wody\nZakres (1,0 – 50) oC PN-EN ISO 5667-6:2016-12 z wyl. pkt 7.5, 7.6 | PN-77/C-04584","categories":["water"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Sampling for chemical and physical testing Temperature of water / of the water sample taken Range PN-EN ISO 5667-6:2016-12 z wył. pkt 7.5, 7.6 | PN-77/C-04584","parameters_zh":[{"name":"范围","range":"(1,0 – 50) oC"}],"search_zh":"水 用于化学与物理检验的采样 水/所采水样的温度 范围 PN-EN ISO 5667-6:2016-12 z wył. pkt 7.5, 7.6 | PN-77/C-04584","test_object_zh":"水","methodology_zh":"用于化学与物理检验的采样 水/所采水样的温度"},{"_id":"6a5dc9adf1c10c8ce825ab94","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie tlenu rozpuszczonego","methodology_en":"Dissolved oxygen concentration","parameters":[{"name":"Zakres","range":"(0,5 – 15) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,5 – 15) mg/dm3"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Stężenie tlenu rozpuszczonego\nZakres (0,5 – 15) mg/dm3\nMetoda elektrochemiczna","reference":"PN-EN ISO 5814:2013","norm_bases":["PN-EN ISO 5814:2013"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie tlenu rozpuszczonego\nZakres (0,5 – 15) mg/dm3\nMetoda elektrochemiczna PN-EN ISO 5814:2013 Woda Stezenie tlenu rozpuszczonego\nZakres (0,5 – 15) mg/dm3\nMetoda elektrochemiczna PN-EN ISO 5814:2013","categories":["water"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Dissolved oxygen concentration Electrochemical method Range PN-EN ISO 5814:2013","parameters_zh":[{"name":"范围","range":"(0,5 – 15) mg/dm3"}],"search_zh":"水 溶解氧浓度 电化学法 范围 PN-EN ISO 5814:2013","technique_zh":"电化学法","test_object_zh":"水","methodology_zh":"溶解氧浓度"},{"_id":"6a5dc9adf1c10c8ce825ab95","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Przewodność elektryczna właściwa w 20 oC","methodology_en":"Electrical conductivity at 20 oC","parameters":[{"name":"Zakres","range":"(100 – 20000) μS/cm"}],"parameters_en":[{"name":"Range","range":"(100 – 20000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"technique_en":"Conductometric method","computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa w 20 oC\nZakres (100 – 20000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Przewodność elektryczna właściwa w 20 oC\nZakres (100 – 20000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda Przewodnosc elektryczna wlasciwa w 20 oC\nZakres (100 – 20000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Electrical conductivity at 20 oC Conductometric method Range PN-EN 27888:1999","parameters_zh":[{"name":"范围","range":"(100 – 20000) μS/cm"}],"search_zh":"水 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水"},{"_id":"6a5dc9adf1c10c8ce825ab96","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009","norm_bases":["PN-ISO 10381-4:2007","PN-ISO 10381-5:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009 Gleba Pobieranie probek do badan chemicznych i fizycznych PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009","categories":["environment"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Soil Sampling for chemical and physical testing PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009","methodology_zh":"化学与物理检测用样品采集","search_zh":"土壤 化学与物理检测用样品采集 PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009","test_object_zh":"土壤"},{"_id":"6a5dc9adf1c10c8ce825ab97","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, Scieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"水、污水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、污水"},{"_id":"6a5dc9adf1c10c8ce825ab98","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Odpady","test_object_en":"Waste","methodology":"Badania interwencyjne (wg. programu DAB-11)","methodology_en":"Intervention testing (according to programme DAB-11)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Badania interwencyjne (wg. programu DAB-11)","reference":"PB-11/CLB wydanie 1 z dnia 25.09.2023r.","norm_bases":["PB-11/CLB wydanie 1 z dnia 25.09.2023r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady Badania interwencyjne (wg. programu DAB-11) PB-11/CLB wydanie 1 z dnia 25.09.2023r. Odpady Badania interwencyjne (wg. programu DAB-11) PB-11/CLB wydanie 1 z dnia 25.09.2023r.","categories":["environment"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste Intervention testing (according to programme DAB-11) PB-11/CLB wydanie 1 z dnia 25.09.2023r.","search_zh":"废物 PB-11/CLB wydanie 1 z dnia 25.09.2023r.","test_object_zh":"废物"},{"_id":"6a5dc9adf1c10c8ce825ab99","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Pobieranie próbek do badań chemicznych, fizycznych i biologicznych","methodology_en":"Sampling for chemical, physical and biological testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych, fizycznych i biologicznych","reference":"PN-EN ISO 5667-13:2011","norm_bases":["PN-EN ISO 5667-13:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Pobieranie próbek do badań chemicznych, fizycznych i biologicznych PN-EN ISO 5667-13:2011 Osady sciekowe Pobieranie probek do badan chemicznych, fizycznych i biologicznych PN-EN ISO 5667-13:2011","categories":["water"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge Sampling for chemical, physical and biological testing PN-EN ISO 5667-13:2011","search_zh":"污泥 用于化学、物理与生物检验的采样 PN-EN ISO 5667-13:2011","test_object_zh":"污泥","methodology_zh":"用于化学、物理与生物检验的采样"},{"_id":"6a5dc9adf1c10c8ce825ab9a","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania frakcji pyłu","methodology_en":"Sampling for determination of the dust fraction","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania frakcji pyłu","reference":"PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02","norm_bases":["PN-Z-04030-7:1994","PN-EN 13284-1:2018-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania frakcji pyłu PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 Gazy odlotowe Pobieranie probek do oznaczania frakcji pylu PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02","categories":["other"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of the dust fraction PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02","search_zh":"废气 用于测定粉尘分级的采样 PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02","test_object_zh":"废气","methodology_zh":"用于测定粉尘分级的采样"},{"_id":"6a5dc9adf1c10c8ce825ab9b","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja frakcji pyłu ( z obliczeń)","methodology_en":"Emission of dust fractions ( calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja frakcji pyłu ( z obliczeń)","reference":"PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02","norm_bases":["PN-Z-04030-7:1994","PN-EN 13284-1:2018-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja frakcji pyłu ( z obliczeń) PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 Gazy odlotowe Emisja frakcji pylu ( z obliczen) PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02","categories":["environment"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Emission of dust fractions ( calculated) PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02","search_zh":"废气 PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02","test_object_zh":"废气"},{"_id":"6a5dc9adf1c10c8ce825ab9c","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek pyłu do oznaczania metali ciężkich w pyle","methodology_en":"Dust sampling for determination of heavy metals in dust","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek pyłu do oznaczania metali ciężkich w pyle","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek pyłu do oznaczania metali ciężkich w pyle PN-Z-04030-7:1994 Gazy odlotowe Pobieranie probek pylu do oznaczania metali ciezkich w pyle PN-Z-04030-7:1994","categories":["materials"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Dust sampling for determination of heavy metals in dust PN-Z-04030-7:1994","search_zh":"废气 PN-Z-04030-7:1994","test_object_zh":"废气"},{"_id":"6a5dc9adf1c10c8ce825ab9d","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja metali ciężkich w pyle (z obliczeń)","methodology_en":"Emission of heavy metals in dust (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja metali ciężkich w pyle (z obliczeń)","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja metali ciężkich w pyle (z obliczeń) PN-Z-04030-7:1994 Gazy odlotowe Emisja metali ciezkich w pyle (z obliczen) PN-Z-04030-7:1994","categories":["materials","environment"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Emission of heavy metals in dust (calculated) PN-Z-04030-7:1994","search_zh":"废气 PN-Z-04030-7:1994","test_object_zh":"废气"},{"_id":"6a5dc9adf1c10c8ce825ab9e","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Próbki pyłu","test_object_en":"Dust samples","methodology":"Udział frakcji pyłu (skład ziarnowy) w tym PM2,5 oraz PM10","methodology_en":"Share of dust fractions (particle size distribution) including PM2,5 and PM10","parameters":[{"name":"Zakres","range":"(0,1 – 100) μm"},{"name":"Zakres","range":"(0 – 100) %"}],"parameters_en":[{"name":"Range","range":"(0,1 – 100) μm"},{"name":"Range","range":"(0 – 100) %"}],"technique":"Metoda dyfrakcji laserowej z dyspersją w cieczy","techniques":["Metoda dyfrakcji laserowej z dyspersją w cieczy"],"technique_en":"Laser diffraction method with liquid dispersion","computed":[],"computed_en":[],"activity":"Udział frakcji pyłu (skład ziarnowy) w tym PM2,5 oraz PM10\nZakres:\nZakres (0,1 – 100) μm\nZakres (0 – 100) %\nMetoda dyfrakcji laserowej z dyspersją w cieczy","reference":"ISO 13320:2020","norm_bases":["ISO 13320:2020"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Próbki pyłu Udział frakcji pyłu (skład ziarnowy) w tym PM2,5 oraz PM10\nZakres:\nZakres (0,1 – 100) μm\nZakres (0 – 100) %\nMetoda dyfrakcji laserowej z dyspersją w cieczy ISO 13320:2020 Probki pylu Udzial frakcji pylu (sklad ziarnowy) w tym PM2,5 oraz PM10\nZakres:\nZakres (0,1 – 100) μm\nZakres (0 – 100) %\nMetoda dyfrakcji laserowej z dyspersja w cieczy ISO 13320:2020","categories":["other"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Dust samples Share of dust fractions (particle size distribution) including PM2,5 and PM10 Laser diffraction method with liquid dispersion Range Range ISO 13320:2020","parameters_zh":[{"name":"范围","range":"(0,1 – 100) μm"},{"name":"范围","range":"(0 – 100) %"}],"search_zh":"粉尘样品 液相分散激光衍射法 范围 范围 ISO 13320:2020","technique_zh":"液相分散激光衍射法","test_object_zh":"粉尘样品"},{"_id":"6a5dc9adf1c10c8ce825ab9f","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","test_object_en":"General environment – noise from installations, equipment and industrial plants","methodology":"Równoważny poziom dźwięku A","methodology_en":"A-weighted equivalent sound pressure level","parameters":[{"name":"Zakres","range":"(24 – 135) dB"}],"parameters_en":[{"name":"Range","range":"(24 – 135) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A\nZakres (24 – 135) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) z wyłączeniem punktu F","norm_bases":["Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) z wyłączeniem punktu F"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A\nZakres (24 – 135) dB\nMetoda pomiarowa bezpośrednia Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) z wyłączeniem punktu F Srodowisko ogolne – halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A\nZakres (24 – 135) dB\nMetoda pomiarowa bezposrednia Zalacznik nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) z wylaczeniem punktu F","categories":["environment"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level Direct measurement method Range Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) z wyłączeniem punktu F","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"范围","range":"(24 – 135) dB"}],"search_zh":"一般环境 – 来自设施、设备与工业企业的噪声 A 计权等效声级 直接测量法 范围 Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) z wyłączeniem punktu F","technique_zh":"直接测量法","test_object_zh":"一般环境 – 来自设施、设备与工业企业的噪声"},{"_id":"6a5dc9adf1c10c8ce825aba0","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","test_object_en":"General environment – noise from installations, equipment and industrial plants","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","methodology_en":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) z wyłączeniem punktu F","norm_bases":["Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) z wyłączeniem punktu F"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) z wyłączeniem punktu F Srodowisko ogolne – halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen) Zalacznik nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) z wylaczeniem punktu F","categories":["environment"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) z wyłączeniem punktu F","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境 – 来自设施、设备与工业企业的噪声 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值） Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) z wyłączeniem punktu F","test_object_zh":"一般环境 – 来自设施、设备与工业企业的噪声"},{"_id":"6a5dc9adf1c10c8ce825aba1","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Środowisko ogólne – hałas impulsowy pochodzący od instalacji, urządzeń i zakładów przemysłowych","test_object_en":"General environment – impulse noise from installations, equipment and industrial plants","methodology":"Równoważny poziom dźwięku A","methodology_en":"A-weighted equivalent sound pressure level","parameters":[{"name":"Zakres","range":"(24 – 135) dB"}],"parameters_en":[{"name":"Range","range":"(24 – 135) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A\nZakres (24 – 135) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706)","norm_bases":["Załącznik nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne – hałas impulsowy pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A\nZakres (24 – 135) dB\nMetoda pomiarowa bezpośrednia Załącznik nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) Srodowisko ogolne – halas impulsowy pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A\nZakres (24 – 135) dB\nMetoda pomiarowa bezposrednia Zalacznik nr 8 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706)","categories":["environment"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"General environment – impulse noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level Direct measurement method Range Załącznik nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706)","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"范围","range":"(24 – 135) dB"}],"search_zh":"一般环境 － 来自装置、设备与工业企业的脉冲噪声 A 计权等效声级 直接测量法 范围 Załącznik nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706)","technique_zh":"直接测量法","test_object_zh":"一般环境 － 来自装置、设备与工业企业的脉冲噪声"},{"_id":"6a5dc9adf1c10c8ce825aba2","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Środowisko ogólne – hałas impulsowy pochodzący od instalacji, urządzeń i zakładów przemysłowych","test_object_en":"General environment – impulse noise from installations, equipment and industrial plants","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","methodology_en":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"Załącznik nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706)","norm_bases":["Załącznik nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne – hałas impulsowy pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Załącznik nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) Srodowisko ogolne – halas impulsowy pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen) Zalacznik nr 8 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706)","categories":["environment"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"General environment – impulse noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706)","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境 － 来自装置、设备与工业企业的脉冲噪声 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值） Załącznik nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706)","test_object_zh":"一般环境 － 来自装置、设备与工业企业的脉冲噪声"},{"_id":"6a5dc9adf1c10c8ce825aba3","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od dróg, linii kolejowych, linii tramwajowych","test_object_en":"General environment – noise from roads, railway lines, tram lines","methodology":"Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A","methodology_en":"A-weighted equivalent sound level A-weighted sound exposure level","parameters":[{"name":"Zakres","range":"(24 – 135) dB"}],"parameters_en":[{"name":"Range","range":"(24 – 135) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A\nZakres (24 – 135) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. 2011 nr 140 poz. 824 i nr 288, poz. 1697) z wyłączeniem punktu H","norm_bases":["Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. 2011 nr 140 poz. 824 i nr 288, poz. 1697) z wyłączeniem punktu H"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne – hałas pochodzący od dróg, linii kolejowych, linii tramwajowych Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A\nZakres (24 – 135) dB\nMetoda pomiarowa bezpośrednia Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. 2011 nr 140 poz. 824 i nr 288, poz. 1697) z wyłączeniem punktu H Srodowisko ogolne – halas pochodzacy od drog, linii kolejowych, linii tramwajowych Rownowazny poziom dzwieku A Ekspozycyjny poziom dzwieku A\nZakres (24 – 135) dB\nMetoda pomiarowa bezposrednia Zalacznik nr 3 do Rozporzadzenia Ministra Srodowiska z dnia 16.06.2011 r. (Dz. U. 2011 nr 140 poz. 824 i nr 288, poz. 1697) z wylaczeniem punktu H","categories":["environment"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"General environment – noise from roads, railway lines, tram lines A-weighted equivalent sound level A-weighted sound exposure level Direct measurement method Range Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. 2011 nr 140 poz. 824 i nr 288, poz. 1697) z wyłączeniem punktu H","parameters_zh":[{"name":"范围","range":"(24 – 135) dB"}],"search_zh":"一般环境 — 来自道路、铁路线、有轨电车线的噪声 A 计权等效声级 A 计权声暴露级 直接测量法 范围 Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. 2011 nr 140 poz. 824 i nr 288, poz. 1697) z wyłączeniem punktu H","technique_zh":"直接测量法","test_object_zh":"一般环境 — 来自道路、铁路线、有轨电车线的噪声","methodology_zh":"A 计权等效声级 A 计权声暴露级"},{"_id":"6a5dc9adf1c10c8ce825aba4","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od dróg, linii kolejowych, linii tramwajowych","test_object_en":"General environment – noise from roads, railway lines, tram lines","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","methodology_en":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. 2011 nr 140 poz. 824 i nr 288, poz. 1697) z wyłączeniem punktu H","norm_bases":["Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. 2011 nr 140 poz. 824 i nr 288, poz. 1697) z wyłączeniem punktu H"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne – hałas pochodzący od dróg, linii kolejowych, linii tramwajowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. 2011 nr 140 poz. 824 i nr 288, poz. 1697) z wyłączeniem punktu H Srodowisko ogolne – halas pochodzacy od drog, linii kolejowych, linii tramwajowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen) Zalacznik nr 3 do Rozporzadzenia Ministra Srodowiska z dnia 16.06.2011 r. (Dz. U. 2011 nr 140 poz. 824 i nr 288, poz. 1697) z wylaczeniem punktu H","categories":["environment"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"General environment – noise from roads, railway lines, tram lines A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. 2011 nr 140 poz. 824 i nr 288, poz. 1697) z wyłączeniem punktu H","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境 — 来自道路、铁路线、有轨电车线的噪声 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值） Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. 2011 nr 140 poz. 824 i nr 288, poz. 1697) z wyłączeniem punktu H","test_object_zh":"一般环境 — 来自道路、铁路线、有轨电车线的噪声"},{"_id":"6a5dc9adf1c10c8ce825aba5","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od lotnisk","test_object_en":"General environment – noise from airports","methodology":"Ekspozycyjny poziom dźwięku A Równoważny poziom dźwięku A","methodology_en":"A-weighted sound exposure level A-weighted equivalent sound level","parameters":[{"name":"Zakres","range":"(24 – 130) dB"}],"parameters_en":[{"name":"Range","range":"(24 – 130) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Ekspozycyjny poziom dźwięku A Równoważny poziom dźwięku A\nZakres (24 – 130) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik nr 2 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. 2011 nr 140, poz.824) z wyłączeniem punktu H","norm_bases":["Załącznik nr 2 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. 2011 nr 140, poz.824) z wyłączeniem punktu H"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne – hałas pochodzący od lotnisk Ekspozycyjny poziom dźwięku A Równoważny poziom dźwięku A\nZakres (24 – 130) dB\nMetoda pomiarowa bezpośrednia Załącznik nr 2 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. 2011 nr 140, poz.824) z wyłączeniem punktu H Srodowisko ogolne – halas pochodzacy od lotnisk Ekspozycyjny poziom dzwieku A Rownowazny poziom dzwieku A\nZakres (24 – 130) dB\nMetoda pomiarowa bezposrednia Zalacznik nr 2 do Rozporzadzenia Ministra Srodowiska z dnia 16.06.2011 r. (Dz. U. 2011 nr 140, poz.824) z wylaczeniem punktu H","categories":["environment"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"General environment – noise from airports A-weighted sound exposure level A-weighted equivalent sound level Direct measurement method Range Załącznik nr 2 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. 2011 nr 140, poz.824) z wyłączeniem punktu H","parameters_zh":[{"name":"范围","range":"(24 – 130) dB"}],"search_zh":"一般环境 — 来自机场的噪声 直接测量法 范围 Załącznik nr 2 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. 2011 nr 140, poz.824) z wyłączeniem punktu H","technique_zh":"直接测量法","test_object_zh":"一般环境 — 来自机场的噪声"},{"_id":"6a5dc9adf1c10c8ce825aba6","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od lotnisk","test_object_en":"General environment – noise from airports","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","methodology_en":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"Załącznik nr 2 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. 2011 nr 140, poz.824) z wyłączeniem punktu H","norm_bases":["Załącznik nr 2 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. 2011 nr 140, poz.824) z wyłączeniem punktu H"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne – hałas pochodzący od lotnisk Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Załącznik nr 2 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. 2011 nr 140, poz.824) z wyłączeniem punktu H Srodowisko ogolne – halas pochodzacy od lotnisk Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen) Zalacznik nr 2 do Rozporzadzenia Ministra Srodowiska z dnia 16.06.2011 r. (Dz. U. 2011 nr 140, poz.824) z wylaczeniem punktu H","categories":["environment"],"row_index":21,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"General environment – noise from airports A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik nr 2 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. 2011 nr 140, poz.824) z wyłączeniem punktu H","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境 — 来自机场的噪声 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值） Załącznik nr 2 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. 2011 nr 140, poz.824) z wyłączeniem punktu H","test_object_zh":"一般环境 — 来自机场的噪声"},{"_id":"6a5dc9adf1c10c8ce825aba7","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych","test_object_en":"Environment – electromagnetic field in the vicinity of electric power substations and power lines","methodology":"Natężenie pola elektrycznego:","methodology_en":"Electric field strength:","parameters":[{"name":"w zakresie częstotliwości 50 Hz"},{"name":"Zakres","range":"(1,0 – 20000) V/m"}],"parameters_en":[{"name":"in the frequency range 50 Hz"},{"name":"Range","range":"(1,0 – 20000) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości 50 Hz\nZakres (1,0 – 20000) V/m\nMetoda pomiarowa bezpośrednia","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości 50 Hz\nZakres (1,0 – 20000) V/m\nMetoda pomiarowa bezpośrednia Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) Srodowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci 50 Hz\nZakres (1,0 – 20000) V/m\nMetoda pomiarowa bezposrednia Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","categories":["environment"],"row_index":22,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Environment – electromagnetic field in the vicinity of electric power substations and power lines Electric field strength: Direct measurement method in the frequency range 50 Hz Range Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","methodology_zh":"电场强度：","parameters_zh":[{"name":"频率范围 50 Hz"},{"name":"范围","range":"(1,0 – 20000) V/m"}],"search_zh":"环境 — 变电站与输电线路周围的电磁场 电场强度： 直接测量法 频率范围 50 Hz 范围 Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","technique_zh":"直接测量法","test_object_zh":"环境 — 变电站与输电线路周围的电磁场"},{"_id":"6a5dc9adf1c10c8ce825aba8","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych","test_object_en":"Environment – electromagnetic field in the vicinity of electric power substations and power lines","methodology":"Indukcja magnetyczna:","methodology_en":"Magnetic flux density:","parameters":[{"name":"w zakresie częstotliwości 50 Hz"},{"name":"Zakres","range":"1μT – 10 mT"}],"parameters_en":[{"name":"in the frequency range 50 Hz"},{"name":"Range","range":"1μT – 10 mT"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Indukcja magnetyczna:\nZakres:\nw zakresie częstotliwości 50 Hz\nZakres 1μT – 10 mT\nMetoda pomiarowa bezpośrednia","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Indukcja magnetyczna:\nZakres:\nw zakresie częstotliwości 50 Hz\nZakres 1μT – 10 mT\nMetoda pomiarowa bezpośrednia Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) Srodowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Indukcja magnetyczna:\nZakres:\nw zakresie czestotliwosci 50 Hz\nZakres 1μT – 10 mT\nMetoda pomiarowa bezposrednia Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","categories":["environment"],"row_index":23,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Environment – electromagnetic field in the vicinity of electric power substations and power lines Magnetic flux density: Direct measurement method in the frequency range 50 Hz Range Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","parameters_zh":[{"name":"频率范围 50 Hz"},{"name":"范围","range":"1μT – 10 mT"}],"search_zh":"环境 — 变电站与输电线路周围的电磁场 磁感应强度： 直接测量法 频率范围 50 Hz 范围 Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","technique_zh":"直接测量法","test_object_zh":"环境 — 变电站与输电线路周围的电磁场","methodology_zh":"磁感应强度："},{"_id":"6a5dc9adf1c10c8ce825aba9","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych","test_object_en":"Environment – electromagnetic field in the vicinity of electric power substations and power lines","methodology":"Natężenie pola magnetycznego:","methodology_en":"Magnetic field strength:","parameters":[{"name":"w zakresie częstotliwości 50 Hz (z obliczeń)"}],"parameters_en":[{"name":"in the frequency range 50 Hz (calculated)"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego:\nw zakresie częstotliwości 50 Hz (z obliczeń)","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Natężenie pola magnetycznego:\nw zakresie częstotliwości 50 Hz (z obliczeń) Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) Srodowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Natezenie pola magnetycznego:\nw zakresie czestotliwosci 50 Hz (z obliczen) Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","categories":["environment"],"row_index":24,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Environment – electromagnetic field in the vicinity of electric power substations and power lines Magnetic field strength: in the frequency range 50 Hz (calculated) Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","methodology_zh":"磁场强度：","search_zh":"环境 — 变电站与输电线路周围的电磁场 磁场强度： 频率 50 Hz 范围内（由计算得出） Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","test_object_zh":"环境 — 变电站与输电线路周围的电磁场","parameters_zh":[{"name":"频率 50 Hz 范围内（由计算得出）"}]},{"_id":"6a5dc9adf1c10c8ce825abaa","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe)","test_object_en":"Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements)","methodology":"Natężenie pola elektrycznego:","methodology_en":"Electric field strength:","parameters":[{"name":"w zakresie częstotliwości: od 10 MHz","range":"do 40 GHz"},{"name":"Zakres","range":"(0,8 – 300) V/m"}],"parameters_en":[{"name":"in the frequency range: from 10 MHz","range":"do 40 GHz"},{"name":"Range","range":"(0,8 – 300) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości: od 10 MHz do 40 GHz\nZakres (0,8 – 300) V/m\nMetoda pomiarowa bezpośrednia","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe) Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości: od 10 MHz do 40 GHz\nZakres (0,8 – 300) V/m\nMetoda pomiarowa bezpośrednia Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) Srodowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe) Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci: od 10 MHz do 40 GHz\nZakres (0,8 – 300) V/m\nMetoda pomiarowa bezposrednia Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","categories":["environment"],"row_index":25,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Electric field strength: Direct measurement method in the frequency range: from 10 MHz Range Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","methodology_zh":"电场强度：","parameters_zh":[{"name":"w zakresie częstotliwości: od 10 MHz","range":"do 40 GHz"},{"name":"范围","range":"(0,8 – 300) V/m"}],"search_zh":"环境 – 无线电通信设施周围的电磁场（宽带测量） 电场强度： 直接测量法 范围 Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","technique_zh":"直接测量法","test_object_zh":"环境 – 无线电通信设施周围的电磁场（宽带测量）"},{"_id":"6a5dc9adf1c10c8ce825abab","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe)","test_object_en":"Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements)","methodology":"Natężenie pola magnetycznego:","methodology_en":"Magnetic field strength:","parameters":[{"name":"w zakresie częstotliwości od 10 MHz","range":"do 40 GHz"},{"name":"(z obliczeń)"}],"parameters_en":[{"name":"in the frequency range from 10 MHz","range":"do 40 GHz"},{"name":"(calculated)"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 10 MHz do 40 GHz\n(z obliczeń)","reference":"Punkt 3 załącznika do Rozporządzenia Ministra Klimatu dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","norm_bases":["Punkt 3 załącznika do Rozporządzenia Ministra Klimatu dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe) Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 10 MHz do 40 GHz\n(z obliczeń) Punkt 3 załącznika do Rozporządzenia Ministra Klimatu dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) Srodowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe) Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 10 MHz do 40 GHz\n(z obliczen) Punkt 3 zalacznika do Rozporzadzenia Ministra Klimatu dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","categories":["environment"],"row_index":26,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Magnetic field strength: in the frequency range from 10 MHz (calculated) Punkt 3 załącznika do Rozporządzenia Ministra Klimatu dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围自 10 MHz 起","range":"do 40 GHz"},{"name":"（计算得出）"}],"search_zh":"环境 – 无线电通信设施周围的电磁场（宽带测量） 磁场强度： 频率范围自 10 MHz 起 （计算得出） Punkt 3 załącznika do Rozporządzenia Ministra Klimatu dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","test_object_zh":"环境 – 无线电通信设施周围的电磁场（宽带测量）"},{"_id":"6a5dc9adf1c10c8ce825abac","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Strumień objętości gazu dla ciśnień dynamicznych >10Pa","methodology_en":"Gas volume flow rate for dynamic pressures >10Pa","parameters":[{"name":"Prędkość gazu"},{"name":"Zakres","range":"(1,0 – 6) m/s"}],"parameters_en":[{"name":"Gas velocity"},{"name":"Range","range":"(1,0 – 6) m/s"}],"technique":"Metoda spiętrzania; Metoda anemometryczna","techniques":["Metoda spiętrzania","Metoda anemometryczna"],"technique_en":"Stagnation pressure method; Anemometric method","computed":[],"computed_en":[],"activity":"Strumień objętości gazu dla ciśnień dynamicznych >10Pa\nZakres:\nPrędkość gazu\nZakres (1,0 – 6) m/s\nMetoda spiętrzania; Metoda anemometryczna","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Strumień objętości gazu dla ciśnień dynamicznych >10Pa\nZakres:\nPrędkość gazu\nZakres (1,0 – 6) m/s\nMetoda spiętrzania; Metoda anemometryczna PN-Z-04030-7:1994 Gazy odlotowe Strumien objetosci gazu dla cisnien dynamicznych >10Pa\nZakres:\nPredkosc gazu\nZakres (1,0 – 6) m/s\nMetoda spietrzania; Metoda anemometryczna PN-Z-04030-7:1994","categories":["other"],"row_index":27,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Gas volume flow rate for dynamic pressures >10Pa Stagnation pressure method; Anemometric method Gas velocity Range PN-Z-04030-7:1994","parameters_zh":[{"name":"Prędkość gazu"},{"name":"范围","range":"(1,0 – 6) m/s"}],"search_zh":"废气 范围 PN-Z-04030-7:1994","test_object_zh":"废气"},{"_id":"6a5dc9adf1c10c8ce825abad","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia pyłu","methodology_en":"Sampling for determination of dust concentration","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia pyłu","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia pyłu PN-Z-04030-7:1994 Gazy odlotowe Pobieranie probek do oznaczania stezenia pylu PN-Z-04030-7:1994","categories":["other"],"row_index":28,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of dust concentration PN-Z-04030-7:1994","search_zh":"废气 粉尘浓度测定采样 PN-Z-04030-7:1994","test_object_zh":"废气","methodology_zh":"粉尘浓度测定采样"},{"_id":"6a5dc9adf1c10c8ce825abae","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie pyłu","methodology_en":"Dust concentration","parameters":[{"name":"Zakres","range":"(0,001 – 100) g/m3"}],"parameters_en":[{"name":"Range","range":"(0,001 – 100) g/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie pyłu\nZakres (0,001 – 100) g/m3\nMetoda grawimetryczna","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie pyłu\nZakres (0,001 – 100) g/m3\nMetoda grawimetryczna PN-Z-04030-7:1994 Gazy odlotowe Stezenie pylu\nZakres (0,001 – 100) g/m3\nMetoda grawimetryczna PN-Z-04030-7:1994","categories":["other"],"row_index":29,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Dust concentration Gravimetric method Range PN-Z-04030-7:1994","methodology_zh":"粉尘浓度","parameters_zh":[{"name":"范围","range":"(0,001 – 100) g/m3"}],"search_zh":"废气 粉尘浓度 重量法 范围 PN-Z-04030-7:1994","technique_zh":"重量法","test_object_zh":"废气"},{"_id":"6a5dc9adf1c10c8ce825abaf","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja pyłu (z obliczeń)","methodology_en":"Dust emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja pyłu (z obliczeń)","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja pyłu (z obliczeń) PN-Z-04030-7:1994 Gazy odlotowe Emisja pylu (z obliczen) PN-Z-04030-7:1994","categories":["environment"],"row_index":30,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Dust emission (calculated) PN-Z-04030-7:1994","search_zh":"废气 粉尘排放量（计算值） PN-Z-04030-7:1994","test_object_zh":"废气","methodology_zh":"粉尘排放量（计算值）"},{"_id":"6a5dc9adf1c10c8ce825abb0","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Prędkość i strumień objętości gazu dla ciśnień różnicowych >5 Pa Metoda pomiaru ciśnienia różnicowego","methodology_en":"Gas velocity and volume flow for differential pressures >5 Pa Differential pressure measurement method","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Prędkość i strumień objętości gazu dla ciśnień różnicowych >5 Pa Metoda pomiaru ciśnienia różnicowego","reference":"PN-EN ISO 16911-1:2013-07 CEN/TR 17078:2017-03","norm_bases":["PN-EN ISO 16911-1:2013-07 CEN/TR 17078:2017-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Prędkość i strumień objętości gazu dla ciśnień różnicowych >5 Pa Metoda pomiaru ciśnienia różnicowego PN-EN ISO 16911-1:2013-07 CEN/TR 17078:2017-03 Gazy odlotowe Predkosc i strumien objetosci gazu dla cisnien roznicowych >5 Pa Metoda pomiaru cisnienia roznicowego PN-EN ISO 16911-1:2013-07 CEN/TR 17078:2017-03","categories":["other"],"row_index":31,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Gas velocity and volume flow for differential pressures >5 Pa Differential pressure measurement method PN-EN ISO 16911-1:2013-07 CEN/TR 17078:2017-03","search_zh":"废气 PN-EN ISO 16911-1:2013-07 CEN/TR 17078:2017-03","test_object_zh":"废气"},{"_id":"6a5dc9adf1c10c8ce825abb1","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Prędkość gazu","methodology_en":"Gas velocity","parameters":[{"name":"Zakres","range":"(1,0 – 6) m/s"}],"parameters_en":[{"name":"Range","range":"(1,0 – 6) m/s"}],"technique":"Metoda anemometryczna","techniques":["Metoda anemometryczna"],"technique_en":"Anemometric method","computed":[],"computed_en":[],"activity":"Prędkość gazu\nZakres (1,0 – 6) m/s\nMetoda anemometryczna","reference":"PN-EN ISO 16911-1:2013-07 CEN/TR 17078:2017-03","norm_bases":["PN-EN ISO 16911-1:2013-07 CEN/TR 17078:2017-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Prędkość gazu\nZakres (1,0 – 6) m/s\nMetoda anemometryczna PN-EN ISO 16911-1:2013-07 CEN/TR 17078:2017-03 Gazy odlotowe Predkosc gazu\nZakres (1,0 – 6) m/s\nMetoda anemometryczna PN-EN ISO 16911-1:2013-07 CEN/TR 17078:2017-03","categories":["other"],"row_index":32,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Gas velocity Anemometric method Range PN-EN ISO 16911-1:2013-07 CEN/TR 17078:2017-03","parameters_zh":[{"name":"范围","range":"(1,0 – 6) m/s"}],"search_zh":"废气 风速仪法 范围 PN-EN ISO 16911-1:2013-07 CEN/TR 17078:2017-03","test_object_zh":"废气","technique_zh":"风速仪法"},{"_id":"6a5dc9adf1c10c8ce825abb2","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia pyłu","methodology_en":"Sampling for determination of dust concentration","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia pyłu","reference":"PN-EN 13284-1:2018-02","norm_bases":["PN-EN 13284-1:2018-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia pyłu PN-EN 13284-1:2018-02 Gazy odlotowe Pobieranie probek do oznaczania stezenia pylu PN-EN 13284-1:2018-02","categories":["other"],"row_index":33,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of dust concentration PN-EN 13284-1:2018-02","search_zh":"废气 粉尘浓度测定采样 PN-EN 13284-1:2018-02","test_object_zh":"废气","methodology_zh":"粉尘浓度测定采样"},{"_id":"6a5dc9adf1c10c8ce825abb3","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie pyłu","methodology_en":"Dust concentration","parameters":[{"name":"Zakres","range":"(1,0 – 50) mg/m3"}],"parameters_en":[{"name":"Range","range":"(1,0 – 50) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie pyłu\nZakres (1,0 – 50) mg/m3\nMetoda grawimetryczna","reference":"PN-EN 13284-1:2018-02","norm_bases":["PN-EN 13284-1:2018-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie pyłu\nZakres (1,0 – 50) mg/m3\nMetoda grawimetryczna PN-EN 13284-1:2018-02 Gazy odlotowe Stezenie pylu\nZakres (1,0 – 50) mg/m3\nMetoda grawimetryczna PN-EN 13284-1:2018-02","categories":["other"],"row_index":34,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Dust concentration Gravimetric method Range PN-EN 13284-1:2018-02","methodology_zh":"粉尘浓度","parameters_zh":[{"name":"范围","range":"(1,0 – 50) mg/m3"}],"search_zh":"废气 粉尘浓度 重量法 范围 PN-EN 13284-1:2018-02","technique_zh":"重量法","test_object_zh":"废气"},{"_id":"6a5dc9adf1c10c8ce825abb4","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja pyłu (z obliczeń)","methodology_en":"Dust emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja pyłu (z obliczeń)","reference":"PN-EN 13284-1:2018-02","norm_bases":["PN-EN 13284-1:2018-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja pyłu (z obliczeń) PN-EN 13284-1:2018-02 Gazy odlotowe Emisja pylu (z obliczen) PN-EN 13284-1:2018-02","categories":["environment"],"row_index":35,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Dust emission (calculated) PN-EN 13284-1:2018-02","search_zh":"废气 粉尘排放量（计算值） PN-EN 13284-1:2018-02","test_object_zh":"废气","methodology_zh":"粉尘排放量（计算值）"},{"_id":"6a5dc9adf1c10c8ce825abb5","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie tlenku węgla","methodology_en":"Carbon monoxide concentration","parameters":[{"name":"CO","range":"(5 – 2900) mg/m3"}],"parameters_en":[{"name":"CO","range":"(5 – 2900) mg/m3"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"technique_en":"Non-dispersive infrared spectrometry (NDIR)","computed":[],"computed_en":[],"activity":"Stężenie tlenku węgla\nCO (5 – 2900) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"PN-ISO 10396:2001 | PN-EN 15058:2017-04","norm_bases":["PN-ISO 10396:2001","PN-EN 15058:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie tlenku węgla\nCO (5 – 2900) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-ISO 10396:2001 | PN-EN 15058:2017-04 Gazy odlotowe Stezenie tlenku wegla\nCO (5 – 2900) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-ISO 10396:2001 | PN-EN 15058:2017-04","categories":["other"],"row_index":36,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Carbon monoxide concentration Non-dispersive infrared spectrometry (NDIR) CO PN-ISO 10396:2001 | PN-EN 15058:2017-04","search_zh":"废气 一氧化碳浓度 非分散红外光谱法（NDIR） CO PN-ISO 10396:2001 | PN-EN 15058:2017-04","test_object_zh":"废气","methodology_zh":"一氧化碳浓度","parameters_zh":[{"name":"CO","range":"(5 – 2900) mg/m3"}],"technique_zh":"非分散红外光谱法（NDIR）"},{"_id":"6a5dc9adf1c10c8ce825abb6","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja tlenku węgla (z obliczeń)","methodology_en":"Carbon monoxide emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja tlenku węgla (z obliczeń)","reference":"PN-ISO 10396:2001 | PN-EN 15058:2017-04","norm_bases":["PN-ISO 10396:2001","PN-EN 15058:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja tlenku węgla (z obliczeń) PN-ISO 10396:2001 | PN-EN 15058:2017-04 Gazy odlotowe Emisja tlenku wegla (z obliczen) PN-ISO 10396:2001 | PN-EN 15058:2017-04","categories":["environment"],"row_index":37,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Carbon monoxide emission (calculated) PN-ISO 10396:2001 | PN-EN 15058:2017-04","search_zh":"废气 一氧化碳排放（由计算得出） PN-ISO 10396:2001 | PN-EN 15058:2017-04","test_object_zh":"废气","methodology_zh":"一氧化碳排放（由计算得出）"},{"_id":"6a5dc9adf1c10c8ce825abb7","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie pary wodnej (H2O)","methodology_en":"Water vapour concentration (H2O)","parameters":[{"name":"Zakres","range":"(4,0 - 40,0) %"},{"name":"Zawartość pary wodnej"},{"name":"Zakres","range":"(29 -250 ) g/m3"}],"parameters_en":[{"name":"Range","range":"(4,0 - 40,0) %"},{"name":"Water vapour content"},{"name":"Range","range":"(29 -250 ) g/m3"}],"technique":"Metoda kondensacyjno-adsorpcyjna","techniques":["Metoda kondensacyjno-adsorpcyjna"],"technique_en":"Condensation-adsorption method","computed":[],"computed_en":[],"activity":"Stężenie pary wodnej (H2O)\nZakres:\nZakres (4,0 - 40,0) %\nZawartość pary wodnej\nZakres (29 -250 ) g/m3\nMetoda kondensacyjno-adsorpcyjna","reference":"PN-EN 14790:2017-04","norm_bases":["PN-EN 14790:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie pary wodnej (H2O)\nZakres:\nZakres (4,0 - 40,0) %\nZawartość pary wodnej\nZakres (29 -250 ) g/m3\nMetoda kondensacyjno-adsorpcyjna PN-EN 14790:2017-04 Gazy odlotowe Stezenie pary wodnej (H2O)\nZakres:\nZakres (4,0 - 40,0) %\nZawartosc pary wodnej\nZakres (29 -250 ) g/m3\nMetoda kondensacyjno-adsorpcyjna PN-EN 14790:2017-04","categories":["other"],"row_index":38,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Water vapour concentration (H2O) Condensation-adsorption method Range Water vapour content Range PN-EN 14790:2017-04","parameters_zh":[{"name":"范围","range":"(4,0 - 40,0) %"},{"name":"水蒸气含量"},{"name":"范围","range":"(29 -250 ) g/m3"}],"search_zh":"废气 水蒸气浓度（H2O） 冷凝-吸附法 范围 水蒸气含量 范围 PN-EN 14790:2017-04","test_object_zh":"废气","methodology_zh":"水蒸气浓度（H2O）","technique_zh":"冷凝-吸附法"},{"_id":"6a5dc9adf1c10c8ce825abb8","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie: dwutlenku siarki, dwutlenku węgla","methodology_en":"Concentration of: sulphur dioxide, carbon dioxide","parameters":[{"name":"SO2","range":"(9 – 3000) mg/m3"},{"name":"CO2","range":"(0,1 – 21) %"}],"parameters_en":[{"name":"SO2","range":"(9 – 3000) mg/m3"},{"name":"CO2","range":"(0,1 – 21) %"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"technique_en":"Non-dispersive infrared spectrometry (NDIR)","computed":[],"computed_en":[],"activity":"Stężenie: dwutlenku siarki, dwutlenku węgla\nZakres:\nSO2 (9 – 3000) mg/m3\nCO2 (0,1 – 21) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie: dwutlenku siarki, dwutlenku węgla\nZakres:\nSO2 (9 – 3000) mg/m3\nCO2 (0,1 – 21) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-ISO 10396:2001 Gazy odlotowe Stezenie: dwutlenku siarki, dwutlenku wegla\nZakres:\nSO2 (9 – 3000) mg/m3\nCO2 (0,1 – 21) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-ISO 10396:2001","categories":["other"],"row_index":39,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Concentration of: sulphur dioxide, carbon dioxide Non-dispersive infrared spectrometry (NDIR) SO2 CO2 PN-ISO 10396:2001","search_zh":"废气 非分散红外光谱法（NDIR） SO2 CO2 PN-ISO 10396:2001","test_object_zh":"废气","parameters_zh":[{"name":"SO2","range":"(9 – 3000) mg/m3"},{"name":"CO2","range":"(0,1 – 21) %"}],"technique_zh":"非分散红外光谱法（NDIR）"},{"_id":"6a5dc9adf1c10c8ce825abb9","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja: SO2, CO2 (z obliczeń)","methodology_en":"Emission: SO2, CO2 (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja: SO2, CO2 (z obliczeń)","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja: SO2, CO2 (z obliczeń) PN-ISO 10396:2001 Gazy odlotowe Emisja: SO2, CO2 (z obliczen) PN-ISO 10396:2001","categories":["environment"],"row_index":40,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Emission: SO2, CO2 (calculated) PN-ISO 10396:2001","search_zh":"废气 PN-ISO 10396:2001","test_object_zh":"废气"},{"_id":"6a5dc9adf1c10c8ce825abba","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie masowe ogólnego węgla organicznego (TVOC)","methodology_en":"Mass concentration of total organic carbon (TVOC)","parameters":[{"name":"Zakres","range":"(2 – 500) mg/m3"}],"parameters_en":[{"name":"Range","range":"(2 – 500) mg/m3"}],"technique":"Metoda ciągłego pomiaru z detekcją płomieniowo-jonizacyjną FID","techniques":["Metoda ciągłego pomiaru z detekcją płomieniowo-jonizacyjną FID"],"technique_en":"Continuous measurement method with flame ionization detection FID","computed":[],"computed_en":[],"activity":"Stężenie masowe ogólnego węgla organicznego (TVOC)\nZakres (2 – 500) mg/m3\nMetoda ciągłego pomiaru z detekcją płomieniowo-jonizacyjną FID","reference":"PN-EN 12619:2013","norm_bases":["PN-EN 12619:2013"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie masowe ogólnego węgla organicznego (TVOC)\nZakres (2 – 500) mg/m3\nMetoda ciągłego pomiaru z detekcją płomieniowo-jonizacyjną FID PN-EN 12619:2013 Gazy odlotowe Stezenie masowe ogolnego wegla organicznego (TVOC)\nZakres (2 – 500) mg/m3\nMetoda ciaglego pomiaru z detekcja plomieniowo-jonizacyjna FID PN-EN 12619:2013","categories":["other"],"row_index":41,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Mass concentration of total organic carbon (TVOC) Continuous measurement method with flame ionization detection FID Range PN-EN 12619:2013","parameters_zh":[{"name":"范围","range":"(2 – 500) mg/m3"}],"search_zh":"废气 范围 PN-EN 12619:2013","test_object_zh":"废气"},{"_id":"6a5dc9adf1c10c8ce825abbb","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja ogólnego węgla organicznego (TVOC) (z obliczeń)","methodology_en":"Emission of total organic carbon (TVOC) (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja ogólnego węgla organicznego (TVOC) (z obliczeń)","reference":"PN-EN 12619:2013","norm_bases":["PN-EN 12619:2013"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja ogólnego węgla organicznego (TVOC) (z obliczeń) PN-EN 12619:2013 Gazy odlotowe Emisja ogolnego wegla organicznego (TVOC) (z obliczen) PN-EN 12619:2013","categories":["environment"],"row_index":42,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Emission of total organic carbon (TVOC) (calculated) PN-EN 12619:2013","search_zh":"废气 PN-EN 12619:2013","test_object_zh":"废气"},{"_id":"6a5dc9adf1c10c8ce825abbc","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie tlenu","methodology_en":"Oxygen concentration","parameters":[{"name":"Zakres","range":"(0,1 – 21,0) %"}],"parameters_en":[{"name":"Range","range":"(0,1 – 21,0) %"}],"technique":"Metoda paramagnetyczna","techniques":["Metoda paramagnetyczna"],"technique_en":"Paramagnetic method","computed":[],"computed_en":[],"activity":"Stężenie tlenu\nZakres (0,1 – 21,0) %\nMetoda paramagnetyczna","reference":"PN-ISO 10396:2001 | PN-EN 14789:2017-04","norm_bases":["PN-ISO 10396:2001","PN-EN 14789:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie tlenu\nZakres (0,1 – 21,0) %\nMetoda paramagnetyczna PN-ISO 10396:2001 | PN-EN 14789:2017-04 Gazy odlotowe Stezenie tlenu\nZakres (0,1 – 21,0) %\nMetoda paramagnetyczna PN-ISO 10396:2001 | PN-EN 14789:2017-04","categories":["other"],"row_index":43,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Oxygen concentration Paramagnetic method Range PN-ISO 10396:2001 | PN-EN 14789:2017-04","parameters_zh":[{"name":"范围","range":"(0,1 – 21,0) %"}],"search_zh":"废气 氧浓度 顺磁法 范围 PN-ISO 10396:2001 | PN-EN 14789:2017-04","test_object_zh":"废气","methodology_zh":"氧浓度","technique_zh":"顺磁法"},{"_id":"6a5dc9adf1c10c8ce825abbd","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie tlenku azotu, tlenków azotu","methodology_en":"Concentration of nitrogen monoxide, nitrogen oxides","parameters":[{"name":"NO","range":"(2,0 – 1500) mg/m3"},{"name":"NOx","range":"(3,0 – 2100) mg/m3"}],"parameters_en":[{"name":"NO","range":"(2,0 – 1500) mg/m3"},{"name":"NOx","range":"(3,0 – 2100) mg/m3"}],"technique":"Metoda chemiluminescencyjna","techniques":["Metoda chemiluminescencyjna"],"technique_en":"Chemiluminescence method","computed":[],"computed_en":[],"activity":"Stężenie tlenku azotu, tlenków azotu\nZakres:\nNO (2,0 – 1500) mg/m3\nNOx (3,0 – 2100) mg/m3\nMetoda chemiluminescencyjna","reference":"PN-ISO 10396:2001 | PN-EN 14792:2017-04","norm_bases":["PN-ISO 10396:2001","PN-EN 14792:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie tlenku azotu, tlenków azotu\nZakres:\nNO (2,0 – 1500) mg/m3\nNOx (3,0 – 2100) mg/m3\nMetoda chemiluminescencyjna PN-ISO 10396:2001 | PN-EN 14792:2017-04 Gazy odlotowe Stezenie tlenku azotu, tlenkow azotu\nZakres:\nNO (2,0 – 1500) mg/m3\nNOx (3,0 – 2100) mg/m3\nMetoda chemiluminescencyjna PN-ISO 10396:2001 | PN-EN 14792:2017-04","categories":["other"],"row_index":44,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Concentration of nitrogen monoxide, nitrogen oxides Chemiluminescence method NO NOx PN-ISO 10396:2001 | PN-EN 14792:2017-04","search_zh":"废气 一氧化氮、氮氧化物浓度 化学发光法 NO NOx PN-ISO 10396:2001 | PN-EN 14792:2017-04","test_object_zh":"废气","parameters_zh":[{"name":"NO","range":"(2,0 – 1500) mg/m3"},{"name":"NOx","range":"(3,0 – 2100) mg/m3"}],"technique_zh":"化学发光法","methodology_zh":"一氧化氮、氮氧化物浓度"},{"_id":"6a5dc9adf1c10c8ce825abbe","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja: NO, NOx (NO i NO2 w przeliczeniu na NO2) (z obliczeń)","methodology_en":"Emission: NO, NOx (NO and NO2 calculated as NO2) (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja: NO, NOx (NO i NO2 w przeliczeniu na NO2) (z obliczeń)","reference":"PN-ISO 10396:2001 | PN-EN 14792:2017-04","norm_bases":["PN-ISO 10396:2001","PN-EN 14792:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja: NO, NOx (NO i NO2 w przeliczeniu na NO2) (z obliczeń) PN-ISO 10396:2001 | PN-EN 14792:2017-04 Gazy odlotowe Emisja: NO, NOx (NO i NO2 w przeliczeniu na NO2) (z obliczen) PN-ISO 10396:2001 | PN-EN 14792:2017-04","categories":["environment"],"row_index":45,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Emission: NO, NOx (NO and NO2 calculated as NO2) (calculated) PN-ISO 10396:2001 | PN-EN 14792:2017-04","search_zh":"废气 PN-ISO 10396:2001 | PN-EN 14792:2017-04","test_object_zh":"废气"},{"_id":"6a5dc9adf1c10c8ce825abbf","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężeń indywidualnych gazowych związków organicznych","methodology_en":"Sampling for the determination of concentrations of individual gaseous organic compounds","parameters":[],"parameters_en":[],"technique":"Metoda aspiracyjna z zastosowaniem węgla aktywnego","techniques":["Metoda aspiracyjna z zastosowaniem węgla aktywnego"],"technique_en":"Aspiration method using activated carbon","computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężeń indywidualnych gazowych związków organicznych\nMetoda aspiracyjna z zastosowaniem węgla aktywnego","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężeń indywidualnych gazowych związków organicznych\nMetoda aspiracyjna z zastosowaniem węgla aktywnego PN-EN 13649:2005 Gazy odlotowe Pobieranie probek do oznaczania stezen indywidualnych gazowych zwiazkow organicznych\nMetoda aspiracyjna z zastosowaniem wegla aktywnego PN-EN 13649:2005","categories":["other"],"row_index":46,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for the determination of concentrations of individual gaseous organic compounds Aspiration method using activated carbon PN-EN 13649:2005","search_zh":"废气 用于测定单个气态有机化合物浓度的采样 活性炭抽气采样法 PN-EN 13649:2005","test_object_zh":"废气","technique_zh":"活性炭抽气采样法","methodology_zh":"用于测定单个气态有机化合物浓度的采样"},{"_id":"6a5dc9adf1c10c8ce825abc0","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja indywidualnych gazowych związków organicznych (z obliczeń)","methodology_en":"Emission of individual gaseous organic compounds (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja indywidualnych gazowych związków organicznych (z obliczeń)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja indywidualnych gazowych związków organicznych (z obliczeń) PN-EN 13649:2005 Gazy odlotowe Emisja indywidualnych gazowych zwiazkow organicznych (z obliczen) PN-EN 13649:2005","categories":["environment"],"row_index":47,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Emission of individual gaseous organic compounds (calculated) PN-EN 13649:2005","search_zh":"废气 单项气态有机化合物排放量（计算值） PN-EN 13649:2005","test_object_zh":"废气","methodology_zh":"单项气态有机化合物排放量（计算值）"},{"_id":"6a5dc9adf1c10c8ce825abc1","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężeń związków organicznych","methodology_en":"Sampling for determination of concentrations of organic compounds","parameters":[],"parameters_en":[],"technique":"Metoda aspiracyjna z zastosowaniem węgla aktywnego i żelu krzemionkowego","techniques":["Metoda aspiracyjna z zastosowaniem węgla aktywnego i żelu krzemionkowego"],"technique_en":"Aspiration method using activated carbon and silica gel","computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężeń związków organicznych\nMetoda aspiracyjna z zastosowaniem węgla aktywnego i żelu krzemionkowego","reference":"PN-Z-04008-4:1999","norm_bases":["PN-Z-04008-4:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężeń związków organicznych\nMetoda aspiracyjna z zastosowaniem węgla aktywnego i żelu krzemionkowego PN-Z-04008-4:1999 Gazy odlotowe Pobieranie probek do oznaczania stezen zwiazkow organicznych\nMetoda aspiracyjna z zastosowaniem wegla aktywnego i zelu krzemionkowego PN-Z-04008-4:1999","categories":["other"],"row_index":48,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of concentrations of organic compounds Aspiration method using activated carbon and silica gel PN-Z-04008-4:1999","search_zh":"废气 有机化合物浓度测定采样 PN-Z-04008-4:1999","test_object_zh":"废气","methodology_zh":"有机化合物浓度测定采样"},{"_id":"6a5dc9adf1c10c8ce825abc2","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja związków organicznych (z obliczeń)","methodology_en":"Emission of organic compounds (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja związków organicznych (z obliczeń)","reference":"PN-Z-04008-4:1999","norm_bases":["PN-Z-04008-4:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja związków organicznych (z obliczeń) PN-Z-04008-4:1999 Gazy odlotowe Emisja zwiazkow organicznych (z obliczen) PN-Z-04008-4:1999","categories":["environment"],"row_index":49,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Emission of organic compounds (calculated) PN-Z-04008-4:1999","search_zh":"废气 有机化合物排放量（计算值） PN-Z-04008-4:1999","test_object_zh":"废气","methodology_zh":"有机化合物排放量（计算值）"},{"_id":"6a5dc9adf1c10c8ce825abc3","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Indeks nadmanganianowy","methodology_en":"Permanganate index","parameters":[{"name":"Zakres","range":"(0,5 – 50) mg/dm3 O2"}],"parameters_en":[{"name":"Range","range":"(0,5 – 50) mg/dm3 O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Indeks nadmanganianowy\nZakres (0,5 – 50) mg/dm3 O2\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Indeks nadmanganianowy\nZakres (0,5 – 50) mg/dm3 O2\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda, Scieki Indeks nadmanganianowy\nZakres (0,5 – 50) mg/dm3 O2\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":50,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Permanganate index Titrimetric method Range PN-EN ISO 8467:2001","methodology_zh":"高锰酸盐指数","parameters_zh":[{"name":"范围","range":"(0,5 – 50) mg/dm3 O2"}],"search_zh":"水、污水 高锰酸盐指数 滴定法 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"水、污水"},{"_id":"6a5dc9adf1c10c8ce825abc4","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Chemiczne zapotrzebowanie tlenu","methodology_en":"Chemical oxygen demand","parameters":[{"name":"ChZT-Cr"},{"name":"Zakres","range":"(10,0 – 4000) mg/dm3 O2"}],"parameters_en":[{"name":"COD-Cr"},{"name":"Range","range":"(10,0 – 4000) mg/dm3 O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (10,0 – 4000) mg/dm3 O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (10,0 – 4000) mg/dm3 O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda, Scieki Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (10,0 – 4000) mg/dm3 O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":51,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Chemical oxygen demand Spectrophotometric method COD-Cr Range PN-ISO 15705:2005","parameters_zh":[{"name":"化学需氧量（COD-Cr）"},{"name":"范围","range":"(10,0 – 4000) mg/dm3 O2"}],"search_zh":"水、污水 化学需氧量（COD） 分光光度法 化学需氧量（COD-Cr） 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水、污水","methodology_zh":"化学需氧量（COD）"},{"_id":"6a5dc9adf1c10c8ce825abc5","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu","methodology_en":"Biochemical oxygen demand","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(0,5 – 6,0) mg/dm3 O2"}],"parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(0,5 – 6,0) mg/dm3 O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,5 – 6,0) mg/dm3 O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,5 – 6,0) mg/dm3 O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Woda, Scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,5 – 6,0) mg/dm3 O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":52,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Biochemical oxygen demand Electrochemical method BOD5 Range PN-EN 1899-2:2002","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(0,5 – 6,0) mg/dm3 O2"}],"search_zh":"水、污水 生化需氧量 电化学法 BZT5（BOD5） 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"水、污水"},{"_id":"6a5dc9adf1c10c8ce825abc6","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu","methodology_en":"Biochemical oxygen demand","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(1,0 – 6000) mg/dm3 O2"}],"parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(1,0 – 6000) mg/dm3 O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1,0 – 6000) mg/dm3 O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1,0 – 6000) mg/dm3 O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Woda, Scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1,0 – 6000) mg/dm3 O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":53,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Biochemical oxygen demand Electrochemical method BOD5 Range PN-EN ISO 5815-1:2019-12","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(1,0 – 6000) mg/dm3 O2"}],"search_zh":"水、污水 生化需氧量 电化学法 BZT5（BOD5） 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"水、污水"},{"_id":"6a5dc9adf1c10c8ce825abc7","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie azotu amonowego","methodology_en":"Ammonium nitrogen concentration","parameters":[{"name":"Zakres","range":"(1,00 – 100) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(1,00 – 100) mg/dm3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego\nZakres (1,00 – 100) mg/dm3\nMetoda miareczkowa","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie azotu amonowego\nZakres (1,00 – 100) mg/dm3\nMetoda miareczkowa PN-ISO 5664:2002 Woda, Scieki Stezenie azotu amonowego\nZakres (1,00 – 100) mg/dm3\nMetoda miareczkowa PN-ISO 5664:2002","categories":["water"],"row_index":54,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Ammonium nitrogen concentration Titrimetric method Range PN-ISO 5664:2002","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(1,00 – 100) mg/dm3"}],"search_zh":"水、污水 氨氮浓度 滴定法 范围 PN-ISO 5664:2002","technique_zh":"滴定法","test_object_zh":"水、污水"},{"_id":"6a5dc9adf1c10c8ce825abc8","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie azotu azotynowego","methodology_en":"Nitrite nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,010 – 10) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,010 – 10) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu azotynowego\nZakres (0,010 – 10) mg/dm3\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie azotu azotynowego\nZakres (0,010 – 10) mg/dm3\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, Scieki Stezenie azotu azotynowego\nZakres (0,010 – 10) mg/dm3\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":55,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Nitrite nitrogen concentration Spectrophotometric method Range PN-EN 26777:1999","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,010 – 10) mg/dm3"}],"search_zh":"水、污水 亚硝态氮浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a5dc9adf1c10c8ce825abc9","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie azotu Kjeldahla","methodology_en":"Kjeldahl nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,50 – 500) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,50 – 500) mg/dm3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie azotu Kjeldahla\nZakres (0,50 – 500) mg/dm3\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie azotu Kjeldahla\nZakres (0,50 – 500) mg/dm3\nMetoda miareczkowa PN-EN 25663:2001 Woda, Scieki Stezenie azotu Kjeldahla\nZakres (0,50 – 500) mg/dm3\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":56,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Kjeldahl nitrogen concentration Titrimetric method Range PN-EN 25663:2001","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(0,50 – 500) mg/dm3"}],"search_zh":"水、污水 凯氏氮浓度 滴定法 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"水、污水"},{"_id":"6a5dc9adf1c10c8ce825abca","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie azotu ogólnego (z obliczeń)","methodology_en":"Total nitrogen concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PB-049/WA wydanie 3 z dnia 15.07.2019 r.","norm_bases":["PB-049/WA wydanie 3 z dnia 15.07.2019 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie azotu ogólnego (z obliczeń) PB-049/WA wydanie 3 z dnia 15.07.2019 r. Woda, Scieki Stezenie azotu ogolnego (z obliczen) PB-049/WA wydanie 3 z dnia 15.07.2019 r.","categories":["water"],"row_index":57,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Total nitrogen concentration (calculated) PB-049/WA wydanie 3 z dnia 15.07.2019 r.","methodology_zh":"总氮浓度（计算值）","search_zh":"水、污水 总氮浓度（计算值） PB-049/WA wydanie 3 z dnia 15.07.2019 r.","test_object_zh":"水、污水"},{"_id":"6a5dc9adf1c10c8ce825abcb","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Całkowite substancje rozpuszczone (TDS)","methodology_en":"Total dissolved solids (TDS)","parameters":[{"name":"Zakres","range":"(50,0 – 2000) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(50,0 – 2000) mg/dm3"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Całkowite substancje rozpuszczone (TDS)\nZakres (50,0 – 2000) mg/dm3\nMetoda wagowa","reference":"PN-EN 15216:2022-03","norm_bases":["PN-EN 15216:2022-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Całkowite substancje rozpuszczone (TDS)\nZakres (50,0 – 2000) mg/dm3\nMetoda wagowa PN-EN 15216:2022-03 Woda, Scieki Calkowite substancje rozpuszczone (TDS)\nZakres (50,0 – 2000) mg/dm3\nMetoda wagowa PN-EN 15216:2022-03","categories":["water"],"row_index":58,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Total dissolved solids (TDS) Gravimetric method Range PN-EN 15216:2022-03","parameters_zh":[{"name":"范围","range":"(50,0 – 2000) mg/dm3"}],"search_zh":"水、污水 溶解性总固体（TDS） 重量法 范围 PN-EN 15216:2022-03","technique_zh":"重量法","test_object_zh":"水、污水","methodology_zh":"溶解性总固体（TDS）"},{"_id":"6a5dc9adf1c10c8ce825abcc","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Zawiesiny ogólne","methodology_en":"Total suspended solids (TSS)","parameters":[{"name":"Zakres","range":"(2,0 – 2000) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(2,0 – 2000) mg/dm3"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 2000) mg/dm3\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Zawiesiny ogólne\nZakres (2,0 – 2000) mg/dm3\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, Scieki Zawiesiny ogolne\nZakres (2,0 – 2000) mg/dm3\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":59,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 2000) mg/dm3"}],"search_zh":"水、污水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"水、污水"},{"_id":"6a5dc9adf1c10c8ce825abcd","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Twardość ogólna (z obliczeń)","methodology_en":"Total hardness (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Twardość ogólna (z obliczeń)","reference":"PB-060/WA wydanie 2 z dnia 15.07.2019 r.","norm_bases":["PB-060/WA wydanie 2 z dnia 15.07.2019 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Twardość ogólna (z obliczeń) PB-060/WA wydanie 2 z dnia 15.07.2019 r. Woda, Scieki Twardosc ogolna (z obliczen) PB-060/WA wydanie 2 z dnia 15.07.2019 r.","categories":["water"],"row_index":60,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Total hardness (calculated) PB-060/WA wydanie 2 z dnia 15.07.2019 r.","search_zh":"水、污水 总硬度（由计算得出） PB-060/WA wydanie 2 z dnia 15.07.2019 r.","test_object_zh":"水、污水","methodology_zh":"总硬度（由计算得出）"},{"_id":"6a5dc9adf1c10c8ce825abce","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie fosforu ogólnego","methodology_en":"Total phosphorus concentration","parameters":[{"name":"Zakres","range":"(0,040 – 56,0) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,040 – 56,0) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,040 – 56,0) mg/dm3\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie fosforu ogólnego\nZakres (0,040 – 56,0) mg/dm3\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010 Woda, Scieki Stezenie fosforu ogolnego\nZakres (0,040 – 56,0) mg/dm3\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":61,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Total phosphorus concentration Spectrophotometric method Range PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,040 – 56,0) mg/dm3"}],"search_zh":"水、污水 总磷浓度 分光光度法 范围 PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a5dc9adf1c10c8ce825abcf","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie substancji ekstrahujących się eterem naftowym","methodology_en":"Concentration of substances extractable with petroleum ether","parameters":[{"name":"Zakres","range":"(0,5 – 2000) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,5 – 2000) mg/dm3"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie substancji ekstrahujących się eterem naftowym\nZakres (0,5 – 2000) mg/dm3\nMetoda wagowa","reference":"PN-86/C-04573.01","norm_bases":["PN-86/C-04573.01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie substancji ekstrahujących się eterem naftowym\nZakres (0,5 – 2000) mg/dm3\nMetoda wagowa PN-86/C-04573.01 Woda, Scieki Stezenie substancji ekstrahujacych sie eterem naftowym\nZakres (0,5 – 2000) mg/dm3\nMetoda wagowa PN-86/C-04573.01","categories":["water"],"row_index":62,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Concentration of substances extractable with petroleum ether Gravimetric method Range PN-86/C-04573.01","parameters_zh":[{"name":"范围","range":"(0,5 – 2000) mg/dm3"}],"search_zh":"水、污水 石油醚可萃取物浓度 重量法 范围 PN-86/C-04573.01","technique_zh":"重量法","test_object_zh":"水、污水","methodology_zh":"石油醚可萃取物浓度"},{"_id":"6a5dc9adf1c10c8ce825abd0","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie ogólnego węgla organicznego","methodology_en":"Total organic carbon concentration","parameters":[{"name":"Zakres","range":"(2,00 – 500) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(2,00 – 500) mg/dm3"}],"technique":"Metoda spektrometrii w zakresie podczerwieni (IR)","techniques":["Metoda spektrometrii w zakresie podczerwieni (IR)"],"technique_en":"Spectrometry method in the infrared range (IR)","computed":[],"computed_en":[],"activity":"Stężenie ogólnego węgla organicznego\nZakres (2,00 – 500) mg/dm3\nMetoda spektrometrii w zakresie podczerwieni (IR)","reference":"PN-EN 1484:1999","norm_bases":["PN-EN 1484:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie ogólnego węgla organicznego\nZakres (2,00 – 500) mg/dm3\nMetoda spektrometrii w zakresie podczerwieni (IR) PN-EN 1484:1999 Woda, Scieki Stezenie ogolnego wegla organicznego\nZakres (2,00 – 500) mg/dm3\nMetoda spektrometrii w zakresie podczerwieni (IR) PN-EN 1484:1999","categories":["water"],"row_index":63,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Total organic carbon concentration Spectrometry method in the infrared range (IR) Range PN-EN 1484:1999","parameters_zh":[{"name":"范围","range":"(2,00 – 500) mg/dm3"}],"search_zh":"水、污水 总有机碳浓度 红外光谱法（IR） 范围 PN-EN 1484:1999","test_object_zh":"水、污水","technique_zh":"红外光谱法（IR）","methodology_zh":"总有机碳浓度"},{"_id":"6a5dc9adf1c10c8ce825abd1","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Indeks oleju mineralnego","methodology_en":"Mineral oil index","parameters":[{"name":"Zakres","range":"(0,1 – 50) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,1 – 50) mg/dm3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Indeks oleju mineralnego\nZakres (0,1 – 50) mg/dm3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN ISO 9377-2:2003","norm_bases":["PN-EN ISO 9377-2:2003"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Indeks oleju mineralnego\nZakres (0,1 – 50) mg/dm3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN ISO 9377-2:2003 Woda, Scieki Indeks oleju mineralnego\nZakres (0,1 – 50) mg/dm3\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN ISO 9377-2:2003","categories":["water","petro"],"row_index":64,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Mineral oil index Gas chromatography with flame ionization detection (GC-FID) Range PN-EN ISO 9377-2:2003","parameters_zh":[{"name":"范围","range":"(0,1 – 50) mg/dm3"}],"search_zh":"水、污水 矿物油指数 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-EN ISO 9377-2:2003","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"水、污水","methodology_zh":"矿物油指数"},{"_id":"6a5dc9adf1c10c8ce825abd2","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie azotu amonowego","methodology_en":"Ammonium nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,05 – 5,0) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,05 – 5,0) mg/dm3"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego\nZakres (0,05 – 5,0) mg/dm3\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 11732:2007 z wyłączeniem punktu 3","norm_bases":["PN-EN ISO 11732:2007 z wyłączeniem punktu 3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie azotu amonowego\nZakres (0,05 – 5,0) mg/dm3\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 11732:2007 z wyłączeniem punktu 3 Woda, Scieki Stezenie azotu amonowego\nZakres (0,05 – 5,0) mg/dm3\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 11732:2007 z wylaczeniem punktu 3","categories":["water"],"row_index":65,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Ammonium nitrogen concentration Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN ISO 11732:2007 z wyłączeniem punktu 3","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,05 – 5,0) mg/dm3"}],"search_zh":"水、污水 氨氮浓度 连续流动分析（CFA）分光光度检测法 范围 PN-EN ISO 11732:2007 z wyłączeniem punktu 3","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"水、污水"},{"_id":"6a5dc9adf1c10c8ce825abd3","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie azotu azotanowego","methodology_en":"Nitrate nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,10 – 50) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,10 – 50) mg/dm3"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","computed":[],"computed_en":[],"activity":"Stężenie azotu azotanowego\nZakres (0,10 – 50) mg/dm3\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 13395:2001","norm_bases":["PN-EN ISO 13395:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie azotu azotanowego\nZakres (0,10 – 50) mg/dm3\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 13395:2001 Woda, Scieki Stezenie azotu azotanowego\nZakres (0,10 – 50) mg/dm3\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 13395:2001","categories":["water"],"row_index":66,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Nitrate nitrogen concentration Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN ISO 13395:2001","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,10 – 50) mg/dm3"}],"search_zh":"水、污水 硝态氮浓度 连续流动分析（CFA）分光光度检测法 范围 PN-EN ISO 13395:2001","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"水、污水"},{"_id":"6a5dc9adf1c10c8ce825abd4","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie azotu azotynowego","methodology_en":"Nitrite nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,003 – 1,0) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,003 – 1,0) mg/dm3"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","computed":[],"computed_en":[],"activity":"Stężenie azotu azotynowego\nZakres (0,003 – 1,0) mg/dm3\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 13395:2001","norm_bases":["PN-EN ISO 13395:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie azotu azotynowego\nZakres (0,003 – 1,0) mg/dm3\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 13395:2001 Woda, Scieki Stezenie azotu azotynowego\nZakres (0,003 – 1,0) mg/dm3\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 13395:2001","categories":["water"],"row_index":67,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Nitrite nitrogen concentration Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN ISO 13395:2001","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,003 – 1,0) mg/dm3"}],"search_zh":"水、污水 亚硝态氮浓度 连续流动分析（CFA）分光光度检测法 范围 PN-EN ISO 13395:2001","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"水、污水"},{"_id":"6a5dc9adf1c10c8ce825abd5","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie fosforu ogólnego","methodology_en":"Total phosphorus concentration","parameters":[{"name":"Zakres","range":"(0,050 – 50,0) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,050 – 50,0) mg/dm3"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,050 – 50,0) mg/dm3\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie fosforu ogólnego\nZakres (0,050 – 50,0) mg/dm3\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Woda, Scieki Stezenie fosforu ogolnego\nZakres (0,050 – 50,0) mg/dm3\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["water"],"row_index":68,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Total phosphorus concentration Inductively coupled plasma optical emission spectrometry (ICP-OES) Range PN-EN ISO 11885:2009","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,050 – 50,0) mg/dm3"}],"search_zh":"水、污水 总磷浓度 电感耦合等离子体原子发射光谱法（ICP-OES） 范围 PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"水、污水"},{"_id":"6a5dc9adf1c10c8ce825abd6","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie indeksu fenolowego/ fenole lotne","methodology_en":"Phenol index / volatile phenols concentration","parameters":[{"name":"Zakres","range":"(0,003 – 0,50) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,003 – 0,50) mg/dm3"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","computed":[],"computed_en":[],"activity":"Stężenie indeksu fenolowego/ fenole lotne\nZakres (0,003 – 0,50) mg/dm3\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 14402:2004 z wyłączeniem punktu 3","norm_bases":["PN-EN ISO 14402:2004 z wyłączeniem punktu 3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie indeksu fenolowego/ fenole lotne\nZakres (0,003 – 0,50) mg/dm3\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 14402:2004 z wyłączeniem punktu 3 Woda, Scieki Stezenie indeksu fenolowego/ fenole lotne\nZakres (0,003 – 0,50) mg/dm3\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 14402:2004 z wylaczeniem punktu 3","categories":["water"],"row_index":69,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Phenol index / volatile phenols concentration Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN ISO 14402:2004 z wyłączeniem punktu 3","parameters_zh":[{"name":"范围","range":"(0,003 – 0,50) mg/dm3"}],"search_zh":"水、污水 连续流动分析（CFA）分光光度检测法 范围 PN-EN ISO 14402:2004 z wyłączeniem punktu 3","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"水、污水"},{"_id":"6a5dc9adf1c10c8ce825abd7","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie cyjanków ogólnych i wolnych","methodology_en":"Total and free cyanide concentration","parameters":[{"name":"Zakres","range":"(0,005 – 5,0) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,005 – 5,0) mg/dm3"}],"technique":"Metoda wstrzykowej analizy przepływowej (FIA) z detekcją spektrofotometryczną","techniques":["Metoda wstrzykowej analizy przepływowej (FIA) z detekcją spektrofotometryczną"],"technique_en":"Flow injection analysis (FIA) with spectrophotometric detection","computed":[],"computed_en":[],"activity":"Stężenie cyjanków ogólnych i wolnych\nZakres (0,005 – 5,0) mg/dm3\nMetoda wstrzykowej analizy przepływowej (FIA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 14403-1:2012","norm_bases":["PN-EN ISO 14403-1:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie cyjanków ogólnych i wolnych\nZakres (0,005 – 5,0) mg/dm3\nMetoda wstrzykowej analizy przepływowej (FIA) z detekcją spektrofotometryczną PN-EN ISO 14403-1:2012 Woda, Scieki Stezenie cyjankow ogolnych i wolnych\nZakres (0,005 – 5,0) mg/dm3\nMetoda wstrzykowej analizy przeplywowej (FIA) z detekcja spektrofotometryczna PN-EN ISO 14403-1:2012","categories":["water"],"row_index":70,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Total and free cyanide concentration Flow injection analysis (FIA) with spectrophotometric detection Range PN-EN ISO 14403-1:2012","parameters_zh":[{"name":"范围","range":"(0,005 – 5,0) mg/dm3"}],"search_zh":"水、污水 总氰化物与游离氰化物浓度 流动注射分析（FIA）分光光度检测法 范围 PN-EN ISO 14403-1:2012","test_object_zh":"水、污水","technique_zh":"流动注射分析（FIA）分光光度检测法","methodology_zh":"总氰化物与游离氰化物浓度"},{"_id":"6a5dc9adf1c10c8ce825abd8","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie cyjanków związanych (z obliczeń)","methodology_en":"Combined cyanide concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie cyjanków związanych (z obliczeń)","reference":"PB-075/WA wydanie 1 z 01.06.2022r.","norm_bases":["PB-075/WA wydanie 1 z 01.06.2022r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie cyjanków związanych (z obliczeń) PB-075/WA wydanie 1 z 01.06.2022r. Woda, Scieki Stezenie cyjankow zwiazanych (z obliczen) PB-075/WA wydanie 1 z 01.06.2022r.","categories":["water"],"row_index":71,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Combined cyanide concentration (calculated) PB-075/WA wydanie 1 z 01.06.2022r.","search_zh":"水、污水 络合氰化物浓度（由计算得出） PB-075/WA wydanie 1 z 01.06.2022r.","test_object_zh":"水、污水","methodology_zh":"络合氰化物浓度（由计算得出）"},{"_id":"6a5dc9adf1c10c8ce825abd9","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie metali","methodology_en":"Metal concentrations","parameters":[{"name":"chrom","range":"(0,0010 – 1,00) mg/dm3"},{"name":"ołów","range":"(0,0010 – 1,00) mg/dm3"},{"name":"miedź","range":"(0,0010 – 1,00) mg/dm3"},{"name":"kadm","range":"(0,00010 – 1,00) mg/dm3"},{"name":"nikiel","range":"(0,0010 – 1,00) mg/dm3"},{"name":"bor","range":"(0,011 – 10,0) mg/dm3"},{"name":"bar","range":"(0,0030 – 1,00) mg/dm3"},{"name":"selen","range":"(0,0010 – 10,0) mg/dm3"},{"name":"sód","range":"(0,050 – 900,0) mg/dm3"},{"name":"molibden","range":"(0,0010 – 1,00) mg/dm3"},{"name":"wapń","range":"(0,10 – 450,0) mg/dm3"},{"name":"cynk","range":"(0,0020 – 10,0) mg/dm3"},{"name":"mangan","range":"(0,0030 – 1,00) mg/dm3"},{"name":"arsen","range":"(0,0010 – 10,0) mg/dm3"},{"name":"żelazo","range":"(0,020 – 10,0) mg/dm3"},{"name":"glin","range":"(0,0050 – 1,00) mg/dm3"},{"name":"magnez","range":"(0,10 – 90,0) mg/dm3"},{"name":"potas","range":"(0,20 – 90,0) mg/dm3"}],"parameters_en":[{"name":"chromium","range":"(0,0010 – 1,00) mg/dm3"},{"name":"lead","range":"(0,0010 – 1,00) mg/dm3"},{"name":"copper","range":"(0,0010 – 1,00) mg/dm3"},{"name":"cadmium","range":"(0,00010 – 1,00) mg/dm3"},{"name":"nickel","range":"(0,0010 – 1,00) mg/dm3"},{"name":"boron","range":"(0,011 – 10,0) mg/dm3"},{"name":"barium","range":"(0,0030 – 1,00) mg/dm3"},{"name":"selenium","range":"(0,0010 – 10,0) mg/dm3"},{"name":"sodium","range":"(0,050 – 900,0) mg/dm3"},{"name":"molybdenum","range":"(0,0010 – 1,00) mg/dm3"},{"name":"calcium","range":"(0,10 – 450,0) mg/dm3"},{"name":"zinc","range":"(0,0020 – 10,0) mg/dm3"},{"name":"manganese","range":"(0,0030 – 1,00) mg/dm3"},{"name":"arsenic","range":"(0,0010 – 10,0) mg/dm3"},{"name":"iron","range":"(0,020 – 10,0) mg/dm3"},{"name":"aluminium","range":"(0,0050 – 1,00) mg/dm3"},{"name":"magnesium","range":"(0,10 – 90,0) mg/dm3"},{"name":"potassium","range":"(0,20 – 90,0) mg/dm3"}],"technique":"Metoda spektometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","computed":[],"computed_en":[],"activity":"Stężenie metali\nZakres:\nchrom (0,0010 – 1,00) mg/dm3\nołów (0,0010 – 1,00) mg/dm3\nmiedź (0,0010 – 1,00) mg/dm3\nkadm (0,00010 – 1,00) mg/dm3\nnikiel (0,0010 – 1,00) mg/dm3\nbor (0,011 – 10,0) mg/dm3\nbar (0,0030 – 1,00) mg/dm3\nselen (0,0010 – 10,0) mg/dm3\nsód (0,050 – 900,0) mg/dm3\nmolibden (0,0010 – 1,00) mg/dm3\nwapń (0,10 – 450,0) mg/dm3\ncynk (0,0020 – 10,0) mg/dm3\nmangan (0,0030 – 1,00) mg/dm3\narsen (0,0010 – 10,0) mg/dm3\nżelazo (0,020 – 10,0) mg/dm3\nglin (0,0050 – 1,00) mg/dm3\nmagnez (0,10 – 90,0) mg/dm3\npotas (0,20 – 90,0) mg/dm3\nMetoda spektometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"PN-EN ISO 17294-2:2024-04","norm_bases":["PN-EN ISO 17294-2:2024-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie metali\nZakres:\nchrom (0,0010 – 1,00) mg/dm3\nołów (0,0010 – 1,00) mg/dm3\nmiedź (0,0010 – 1,00) mg/dm3\nkadm (0,00010 – 1,00) mg/dm3\nnikiel (0,0010 – 1,00) mg/dm3\nbor (0,011 – 10,0) mg/dm3\nbar (0,0030 – 1,00) mg/dm3\nselen (0,0010 – 10,0) mg/dm3\nsód (0,050 – 900,0) mg/dm3\nmolibden (0,0010 – 1,00) mg/dm3\nwapń (0,10 – 450,0) mg/dm3\ncynk (0,0020 – 10,0) mg/dm3\nmangan (0,0030 – 1,00) mg/dm3\narsen (0,0010 – 10,0) mg/dm3\nżelazo (0,020 – 10,0) mg/dm3\nglin (0,0050 – 1,00) mg/dm3\nmagnez (0,10 – 90,0) mg/dm3\npotas (0,20 – 90,0) mg/dm3\nMetoda spektometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) PN-EN ISO 17294-2:2024-04 Woda, Scieki Stezenie metali\nZakres:\nchrom (0,0010 – 1,00) mg/dm3\nolow (0,0010 – 1,00) mg/dm3\nmiedz (0,0010 – 1,00) mg/dm3\nkadm (0,00010 – 1,00) mg/dm3\nnikiel (0,0010 – 1,00) mg/dm3\nbor (0,011 – 10,0) mg/dm3\nbar (0,0030 – 1,00) mg/dm3\nselen (0,0010 – 10,0) mg/dm3\nsod (0,050 – 900,0) mg/dm3\nmolibden (0,0010 – 1,00) mg/dm3\nwapn (0,10 – 450,0) mg/dm3\ncynk (0,0020 – 10,0) mg/dm3\nmangan (0,0030 – 1,00) mg/dm3\narsen (0,0010 – 10,0) mg/dm3\nzelazo (0,020 – 10,0) mg/dm3\nglin (0,0050 – 1,00) mg/dm3\nmagnez (0,10 – 90,0) mg/dm3\npotas (0,20 – 90,0) mg/dm3\nMetoda spektometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) PN-EN ISO 17294-2:2024-04","categories":["materials","water"],"row_index":72,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Metal concentrations Inductively coupled plasma mass spectrometry (ICP-MS) chromium lead copper cadmium nickel boron barium selenium sodium molybdenum calcium zinc manganese arsenic iron aluminium magnesium potassium PN-EN ISO 17294-2:2024-04","methodology_zh":"金属浓度","parameters_zh":[{"name":"铬","range":"(0,0010 – 1,00) mg/dm3"},{"name":"铅","range":"(0,0010 – 1,00) mg/dm3"},{"name":"铜","range":"(0,0010 – 1,00) mg/dm3"},{"name":"镉","range":"(0,00010 – 1,00) mg/dm3"},{"name":"镍","range":"(0,0010 – 1,00) mg/dm3"},{"name":"硼","range":"(0,011 – 10,0) mg/dm3"},{"name":"钡","range":"(0,0030 – 1,00) mg/dm3"},{"name":"硒","range":"(0,0010 – 10,0) mg/dm3"},{"name":"钠","range":"(0,050 – 900,0) mg/dm3"},{"name":"钼","range":"(0,0010 – 1,00) mg/dm3"},{"name":"钙","range":"(0,10 – 450,0) mg/dm3"},{"name":"锌","range":"(0,0020 – 10,0) mg/dm3"},{"name":"锰","range":"(0,0030 – 1,00) mg/dm3"},{"name":"砷","range":"(0,0010 – 10,0) mg/dm3"},{"name":"铁","range":"(0,020 – 10,0) mg/dm3"},{"name":"铝","range":"(0,0050 – 1,00) mg/dm3"},{"name":"镁","range":"(0,10 – 90,0) mg/dm3"},{"name":"钾","range":"(0,20 – 90,0) mg/dm3"}],"search_zh":"水、污水 金属浓度 电感耦合等离子体电离质谱法（ICP-MS） 铬 铅 铜 镉 镍 硼 钡 硒 钠 钼 钙 锌 锰 砷 铁 铝 镁 钾 PN-EN ISO 17294-2:2024-04","test_object_zh":"水、污水","technique_zh":"电感耦合等离子体电离质谱法（ICP-MS）"},{"_id":"6a5dc9adf1c10c8ce825abda","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie anionów","methodology_en":"Anion concentrations","parameters":[{"name":"fluorki","range":"(0,10 – 14) mg/dm3"},{"name":"chlorki","range":"(0,50 – 400) mg/dm3"},{"name":"azotyny","range":"(0,50 – 12) mg/dm3"},{"name":"azotany","range":"(0,50 – 200) mg/dm3"},{"name":"siarczany","range":"(0,50 – 600) mg/dm3"}],"parameters_en":[{"name":"fluorides","range":"(0,10 – 14) mg/dm3"},{"name":"chlorides","range":"(0,50 – 400) mg/dm3"},{"name":"nitrites","range":"(0,50 – 12) mg/dm3"},{"name":"nitrates","range":"(0,50 – 200) mg/dm3"},{"name":"sulfates","range":"(0,50 – 600) mg/dm3"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"technique_en":"Ion chromatography with conductometric detection (IC-CD)","computed":[],"computed_en":[],"activity":"Stężenie anionów\nZakres:\nfluorki (0,10 – 14) mg/dm3\nchlorki (0,50 – 400) mg/dm3\nazotyny (0,50 – 12) mg/dm3\nazotany (0,50 – 200) mg/dm3\nsiarczany (0,50 – 600) mg/dm3\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie anionów\nZakres:\nfluorki (0,10 – 14) mg/dm3\nchlorki (0,50 – 400) mg/dm3\nazotyny (0,50 – 12) mg/dm3\nazotany (0,50 – 200) mg/dm3\nsiarczany (0,50 – 600) mg/dm3\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Woda, Scieki Stezenie anionow\nZakres:\nfluorki (0,10 – 14) mg/dm3\nchlorki (0,50 – 400) mg/dm3\nazotyny (0,50 – 12) mg/dm3\nazotany (0,50 – 200) mg/dm3\nsiarczany (0,50 – 600) mg/dm3\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":73,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Anion concentrations Ion chromatography with conductometric detection (IC-CD) fluorides chlorides nitrites nitrates sulfates PN-EN ISO 10304-1:2009+AC:2012","methodology_zh":"阴离子浓度","search_zh":"水、污水 阴离子浓度 离子色谱-电导检测法（IC-CD） 氟化物 氯化物 亚硝酸盐 硝酸盐 硫酸盐 PN-EN ISO 10304-1:2009+AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水、污水","parameters_zh":[{"name":"氟化物","range":"(0,10 – 14) mg/dm3"},{"name":"氯化物","range":"(0,50 – 400) mg/dm3"},{"name":"亚硝酸盐","range":"(0,50 – 12) mg/dm3"},{"name":"硝酸盐","range":"(0,50 – 200) mg/dm3"},{"name":"硫酸盐","range":"(0,50 – 600) mg/dm3"}]},{"_id":"6a5dc9adf1c10c8ce825abdb","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie surfaktantów niejonowych (substancji powierzchniowo czynnych niejonowych)","methodology_en":"Non-ionic surfactant concentration (non-ionic surface active agents)","parameters":[{"name":"Zakres","range":"(0,200 – 12,0) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,200 – 12,0) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie surfaktantów niejonowych (substancji powierzchniowo czynnych niejonowych)\nZakres (0,200 – 12,0) mg/dm3\nMetoda spektrofotometryczna","reference":"PB-058/WA wydanie 4 z dnia 15.07.2019 r.","norm_bases":["PB-058/WA wydanie 4 z dnia 15.07.2019 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie surfaktantów niejonowych (substancji powierzchniowo czynnych niejonowych)\nZakres (0,200 – 12,0) mg/dm3\nMetoda spektrofotometryczna PB-058/WA wydanie 4 z dnia 15.07.2019 r. Woda, Scieki Stezenie surfaktantow niejonowych (substancji powierzchniowo czynnych niejonowych)\nZakres (0,200 – 12,0) mg/dm3\nMetoda spektrofotometryczna PB-058/WA wydanie 4 z dnia 15.07.2019 r.","categories":["water"],"row_index":74,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Non-ionic surfactant concentration (non-ionic surface active agents) Spectrophotometric method Range PB-058/WA wydanie 4 z dnia 15.07.2019 r.","parameters_zh":[{"name":"范围","range":"(0,200 – 12,0) mg/dm3"}],"search_zh":"水、污水 分光光度法 范围 PB-058/WA wydanie 4 z dnia 15.07.2019 r.","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a5dc9adf1c10c8ce825abdc","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie lotnych związków organicznych","methodology_en":"Concentration of volatile organic compounds","parameters":[{"name":"dichlorometan","range":"(0,50 – 100) μg/dm3"},{"name":"trichlorometan","range":"(0,50 – 100) μg/dm3"},{"name":"tetrachlorometan","range":"(0,50 – 100) μg/dm3"},{"name":"Zakres","range":"1,2-dichloroetan (0,50 – 100) μg/dm3"},{"name":"trichloroetylen","range":"(0,50 – 100) μg/dm3"},{"name":"tetrachloroetylen","range":"(0,50 – 100) μg/dm3"},{"name":"heksachlorobutadien","range":"(0,010 – 100) μg/dm3"},{"name":"benzen","range":"(0,50 – 100) μg/dm3"},{"name":"toluen","range":"(0,50 – 100) μg/dm3"},{"name":"etylobenzen","range":"(0,50 – 100) μg/dm3"},{"name":"ksylen (suma izomerów)","range":"(1,0 – 100) μg/dm3"},{"name":"1,2,3-trichlorobenzen","range":"(0,010 – 100) μg/dm3"},{"name":"1,2,4-trichlorobenzen","range":"(0,010 – 100) μg/dm3"},{"name":"1,3,5-trichlorobenzen","range":"(0,010 – 100) μg/dm3"},{"name":"naftalen","range":"(0,10 – 100) μg/dm3"}],"parameters_en":[{"name":"dichloromethane","range":"(0,50 – 100) μg/dm3"},{"name":"trichloromethane","range":"(0,50 – 100) μg/dm3"},{"name":"tetrachloromethane","range":"(0,50 – 100) μg/dm3"},{"name":"Range","range":"1,2-dichloroetan (0,50 – 100) μg/dm3"},{"name":"trichloroethylene","range":"(0,50 – 100) μg/dm3"},{"name":"tetrachloroethylene","range":"(0,50 – 100) μg/dm3"},{"name":"hexachlorobutadiene","range":"(0,010 – 100) μg/dm3"},{"name":"benzene","range":"(0,50 – 100) μg/dm3"},{"name":"toluene","range":"(0,50 – 100) μg/dm3"},{"name":"ethylbenzene","range":"(0,50 – 100) μg/dm3"},{"name":"xylene (sum of isomers)","range":"(1,0 – 100) μg/dm3"},{"name":"1,2,3-trichlorobenzene","range":"(0,010 – 100) μg/dm3"},{"name":"1,2,4-trichlorobenzene","range":"(0,010 – 100) μg/dm3"},{"name":"1,3,5-trichlorobenzene","range":"(0,010 – 100) μg/dm3"},{"name":"naphthalene","range":"(0,10 – 100) μg/dm3"}],"technique":"Metoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją spektrometrią mas (P&T GC-MS)","techniques":["Metoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją spektrometrią mas (P&T GC-MS)"],"technique_en":"Gas chromatography with purge and trap technique (Purge&Trap) and mass spectrometry detection (P&T GC-MS)","computed":[],"computed_en":[],"activity":"Stężenie lotnych związków organicznych\nZakres:\ndichlorometan (0,50 – 100) μg/dm3\ntrichlorometan (0,50 – 100) μg/dm3\ntetrachlorometan (0,50 – 100) μg/dm3\nZakres 1,2-dichloroetan (0,50 – 100) μg/dm3\ntrichloroetylen (0,50 – 100) μg/dm3\ntetrachloroetylen (0,50 – 100) μg/dm3\nheksachlorobutadien (0,010 – 100) μg/dm3\nbenzen (0,50 – 100) μg/dm3\ntoluen (0,50 – 100) μg/dm3\netylobenzen (0,50 – 100) μg/dm3\nksylen (suma izomerów) (1,0 – 100) μg/dm3\n1,2,3-trichlorobenzen (0,010 – 100) μg/dm3\n1,2,4-trichlorobenzen (0,010 – 100) μg/dm3\n1,3,5-trichlorobenzen (0,010 – 100) μg/dm3\nnaftalen (0,10 – 100) μg/dm3\nMetoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją spektrometrią mas (P&T GC-MS)","reference":"PN-EN ISO 15680:2008","norm_bases":["PN-EN ISO 15680:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie lotnych związków organicznych\nZakres:\ndichlorometan (0,50 – 100) μg/dm3\ntrichlorometan (0,50 – 100) μg/dm3\ntetrachlorometan (0,50 – 100) μg/dm3\nZakres 1,2-dichloroetan (0,50 – 100) μg/dm3\ntrichloroetylen (0,50 – 100) μg/dm3\ntetrachloroetylen (0,50 – 100) μg/dm3\nheksachlorobutadien (0,010 – 100) μg/dm3\nbenzen (0,50 – 100) μg/dm3\ntoluen (0,50 – 100) μg/dm3\netylobenzen (0,50 – 100) μg/dm3\nksylen (suma izomerów) (1,0 – 100) μg/dm3\n1,2,3-trichlorobenzen (0,010 – 100) μg/dm3\n1,2,4-trichlorobenzen (0,010 – 100) μg/dm3\n1,3,5-trichlorobenzen (0,010 – 100) μg/dm3\nnaftalen (0,10 – 100) μg/dm3\nMetoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją spektrometrią mas (P&T GC-MS) PN-EN ISO 15680:2008 Woda, Scieki Stezenie lotnych zwiazkow organicznych\nZakres:\ndichlorometan (0,50 – 100) μg/dm3\ntrichlorometan (0,50 – 100) μg/dm3\ntetrachlorometan (0,50 – 100) μg/dm3\nZakres 1,2-dichloroetan (0,50 – 100) μg/dm3\ntrichloroetylen (0,50 – 100) μg/dm3\ntetrachloroetylen (0,50 – 100) μg/dm3\nheksachlorobutadien (0,010 – 100) μg/dm3\nbenzen (0,50 – 100) μg/dm3\ntoluen (0,50 – 100) μg/dm3\netylobenzen (0,50 – 100) μg/dm3\nksylen (suma izomerow) (1,0 – 100) μg/dm3\n1,2,3-trichlorobenzen (0,010 – 100) μg/dm3\n1,2,4-trichlorobenzen (0,010 – 100) μg/dm3\n1,3,5-trichlorobenzen (0,010 – 100) μg/dm3\nnaftalen (0,10 – 100) μg/dm3\nMetoda chromatografii gazowej z technika wylapywania i wyplukiwania (Purge&Trap) i detekcja spektrometria mas (P&T GC-MS) PN-EN ISO 15680:2008","categories":["water"],"row_index":75,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Concentration of volatile organic compounds Gas chromatography with purge and trap technique (Purge&Trap) and mass spectrometry detection (P&T GC-MS) dichloromethane trichloromethane tetrachloromethane Range trichloroethylene tetrachloroethylene hexachlorobutadiene benzene toluene ethylbenzene xylene (sum of isomers) 1,2,3-trichlorobenzene 1,2,4-trichlorobenzene 1,3,5-trichlorobenzene naphthalene PN-EN ISO 15680:2008","parameters_zh":[{"name":"二氯甲烷","range":"(0,50 – 100) μg/dm3"},{"name":"三氯甲烷","range":"(0,50 – 100) μg/dm3"},{"name":"四氯化碳","range":"(0,50 – 100) μg/dm3"},{"name":"范围","range":"1,2-dichloroetan (0,50 – 100) μg/dm3"},{"name":"三氯乙烯","range":"(0,50 – 100) μg/dm3"},{"name":"四氯乙烯","range":"(0,50 – 100) μg/dm3"},{"name":"六氯丁二烯","range":"(0,010 – 100) μg/dm3"},{"name":"苯","range":"(0,50 – 100) μg/dm3"},{"name":"甲苯","range":"(0,50 – 100) μg/dm3"},{"name":"乙苯","range":"(0,50 – 100) μg/dm3"},{"name":"ksylen (suma izomerów)","range":"(1,0 – 100) μg/dm3"},{"name":"1,2,3-三氯苯","range":"(0,010 – 100) μg/dm3"},{"name":"1,2,4-三氯苯","range":"(0,010 – 100) μg/dm3"},{"name":"1,3,5-三氯苯","range":"(0,010 – 100) μg/dm3"},{"name":"萘","range":"(0,10 – 100) μg/dm3"}],"search_zh":"水、污水 挥发性有机物浓度 吹扫捕集气相色谱-质谱法（P&T GC-MS） 二氯甲烷 三氯甲烷 四氯化碳 范围 三氯乙烯 四氯乙烯 六氯丁二烯 苯 甲苯 乙苯 1,2,3-三氯苯 1,2,4-三氯苯 1,3,5-三氯苯 萘 PN-EN ISO 15680:2008","test_object_zh":"水、污水","methodology_zh":"挥发性有机物浓度","technique_zh":"吹扫捕集气相色谱-质谱法（P&T GC-MS）"},{"_id":"6a5dc9adf1c10c8ce825abdd","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie polichlorowanych bifenyli (PCB)","methodology_en":"Polychlorinated biphenyls (PCB) concentration","parameters":[{"name":"PCB 28","range":"(0,010 – 0,050) μg/dm3"},{"name":"PCB 52","range":"(0,010 – 0,050) μg/dm3"},{"name":"PCB 101","range":"(0,010 – 0,050) μg/dm3"},{"name":"PCB 118","range":"(0,010 – 0,050) μg/dm3"},{"name":"PCB 138","range":"(0,010 – 0,050) μg/dm3"},{"name":"PCB 153","range":"(0,010 – 0,050) μg/dm3"},{"name":"PCB 180","range":"(0,010 – 0,050) μg/dm3"},{"name":"PCB 194","range":"(0,010 – 0,050) μg/dm3"}],"parameters_en":[{"name":"PCB 28","range":"(0,010 – 0,050) μg/dm3"},{"name":"PCB 52","range":"(0,010 – 0,050) μg/dm3"},{"name":"PCB 101","range":"(0,010 – 0,050) μg/dm3"},{"name":"PCB 118","range":"(0,010 – 0,050) μg/dm3"},{"name":"PCB 138","range":"(0,010 – 0,050) μg/dm3"},{"name":"PCB 153","range":"(0,010 – 0,050) μg/dm3"},{"name":"PCB 180","range":"(0,010 – 0,050) μg/dm3"},{"name":"PCB 194","range":"(0,010 – 0,050) μg/dm3"}],"technique":"Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","techniques":["Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)"],"technique_en":"Gas chromatography with electron capture detection (GC-ECD)","computed":[],"computed_en":[],"activity":"Stężenie polichlorowanych bifenyli (PCB)\nZakres:\nPCB 28 (0,010 – 0,050) μg/dm3\nPCB 52 (0,010 – 0,050) μg/dm3\nPCB 101 (0,010 – 0,050) μg/dm3\nPCB 118 (0,010 – 0,050) μg/dm3\nPCB 138 (0,010 – 0,050) μg/dm3\nPCB 153 (0,010 – 0,050) μg/dm3\nPCB 180 (0,010 – 0,050) μg/dm3\nPCB 194 (0,010 – 0,050) μg/dm3\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","reference":"PN-EN ISO 6468:2002","norm_bases":["PN-EN ISO 6468:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie polichlorowanych bifenyli (PCB)\nZakres:\nPCB 28 (0,010 – 0,050) μg/dm3\nPCB 52 (0,010 – 0,050) μg/dm3\nPCB 101 (0,010 – 0,050) μg/dm3\nPCB 118 (0,010 – 0,050) μg/dm3\nPCB 138 (0,010 – 0,050) μg/dm3\nPCB 153 (0,010 – 0,050) μg/dm3\nPCB 180 (0,010 – 0,050) μg/dm3\nPCB 194 (0,010 – 0,050) μg/dm3\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) PN-EN ISO 6468:2002 Woda, Scieki Stezenie polichlorowanych bifenyli (PCB)\nZakres:\nPCB 28 (0,010 – 0,050) μg/dm3\nPCB 52 (0,010 – 0,050) μg/dm3\nPCB 101 (0,010 – 0,050) μg/dm3\nPCB 118 (0,010 – 0,050) μg/dm3\nPCB 138 (0,010 – 0,050) μg/dm3\nPCB 153 (0,010 – 0,050) μg/dm3\nPCB 180 (0,010 – 0,050) μg/dm3\nPCB 194 (0,010 – 0,050) μg/dm3\nMetoda chromatografii gazowej z detekcja wychwytu elektronow (GC-ECD) PN-EN ISO 6468:2002","categories":["water"],"row_index":76,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Polychlorinated biphenyls (PCB) concentration Gas chromatography with electron capture detection (GC-ECD) PCB 28 PCB 52 PCB 101 PCB 118 PCB 138 PCB 153 PCB 180 PCB 194 PN-EN ISO 6468:2002","search_zh":"水、污水 多氯联苯（PCB）浓度 气相色谱-电子捕获检测法（GC-ECD） PCB 28 PCB 52 PCB 101 PCB 118 PCB 138 PCB 153 PCB 180 PN-EN ISO 6468:2002","technique_zh":"气相色谱-电子捕获检测法（GC-ECD）","test_object_zh":"水、污水","parameters_zh":[{"name":"PCB 28","range":"(0,010 – 0,050) μg/dm3"},{"name":"PCB 52","range":"(0,010 – 0,050) μg/dm3"},{"name":"PCB 101","range":"(0,010 – 0,050) μg/dm3"},{"name":"PCB 118","range":"(0,010 – 0,050) μg/dm3"},{"name":"PCB 138","range":"(0,010 – 0,050) μg/dm3"},{"name":"PCB 153","range":"(0,010 – 0,050) μg/dm3"},{"name":"PCB 180","range":"(0,010 – 0,050) μg/dm3"},{"name":"PCB 194","range":"(0,010 – 0,050) μg/dm3"}],"methodology_zh":"多氯联苯（PCB）浓度"},{"_id":"6a5dc9adf1c10c8ce825abde","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie chlorobenzenów","methodology_en":"Chlorobenzene concentration","parameters":[{"name":"Zakres","range":"1,2,3-trichlorobenzen"},{"name":"Zakres","range":"(0,002 – 0,100) μg/dm3"},{"name":"1,2,4-trichlorobenzen","range":"(0,002 – 0,100) μg/dm3"},{"name":"1,3,5-trichlorobenzen","range":"(0,002 – 0,100) μg/dm3"},{"name":"pentachlorobenzen","range":"(0,002 – 0,050) μg/dm3"},{"name":"heksachlorobenzen","range":"(0,002 – 0,050) μg/dm3"}],"parameters_en":[{"name":"Range","range":"1,2,3-trichlorobenzen"},{"name":"Range","range":"(0,002 – 0,100) μg/dm3"},{"name":"1,2,4-trichlorobenzene","range":"(0,002 – 0,100) μg/dm3"},{"name":"1,3,5-trichlorobenzene","range":"(0,002 – 0,100) μg/dm3"},{"name":"pentachlorobenzene","range":"(0,002 – 0,050) μg/dm3"},{"name":"hexachlorobenzene","range":"(0,002 – 0,050) μg/dm3"}],"technique":"Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","techniques":["Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)"],"technique_en":"Gas chromatography with electron capture detection (GC-ECD)","computed":[],"computed_en":[],"activity":"Stężenie chlorobenzenów\nZakres:\nZakres 1,2,3-trichlorobenzen\nZakres (0,002 – 0,100) μg/dm3\n1,2,4-trichlorobenzen (0,002 – 0,100) μg/dm3\n1,3,5-trichlorobenzen (0,002 – 0,100) μg/dm3\npentachlorobenzen (0,002 – 0,050) μg/dm3\nheksachlorobenzen (0,002 – 0,050) μg/dm3\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","reference":"PN-EN ISO 6468:2002","norm_bases":["PN-EN ISO 6468:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie chlorobenzenów\nZakres:\nZakres 1,2,3-trichlorobenzen\nZakres (0,002 – 0,100) μg/dm3\n1,2,4-trichlorobenzen (0,002 – 0,100) μg/dm3\n1,3,5-trichlorobenzen (0,002 – 0,100) μg/dm3\npentachlorobenzen (0,002 – 0,050) μg/dm3\nheksachlorobenzen (0,002 – 0,050) μg/dm3\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) PN-EN ISO 6468:2002 Woda, Scieki Stezenie chlorobenzenow\nZakres:\nZakres 1,2,3-trichlorobenzen\nZakres (0,002 – 0,100) μg/dm3\n1,2,4-trichlorobenzen (0,002 – 0,100) μg/dm3\n1,3,5-trichlorobenzen (0,002 – 0,100) μg/dm3\npentachlorobenzen (0,002 – 0,050) μg/dm3\nheksachlorobenzen (0,002 – 0,050) μg/dm3\nMetoda chromatografii gazowej z detekcja wychwytu elektronow (GC-ECD) PN-EN ISO 6468:2002","categories":["water"],"row_index":77,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Chlorobenzene concentration Gas chromatography with electron capture detection (GC-ECD) Range Range 1,2,4-trichlorobenzene 1,3,5-trichlorobenzene pentachlorobenzene hexachlorobenzene PN-EN ISO 6468:2002","parameters_zh":[{"name":"范围","range":"1,2,3-trichlorobenzen"},{"name":"范围","range":"(0,002 – 0,100) μg/dm3"},{"name":"1,2,4-三氯苯","range":"(0,002 – 0,100) μg/dm3"},{"name":"1,3,5-三氯苯","range":"(0,002 – 0,100) μg/dm3"},{"name":"五氯苯","range":"(0,002 – 0,050) μg/dm3"},{"name":"六氯苯","range":"(0,002 – 0,050) μg/dm3"}],"search_zh":"水、污水 氯苯类浓度 气相色谱-电子捕获检测法（GC-ECD） 范围 范围 1,2,4-三氯苯 1,3,5-三氯苯 五氯苯 六氯苯 PN-EN ISO 6468:2002","technique_zh":"气相色谱-电子捕获检测法（GC-ECD）","test_object_zh":"水、污水","methodology_zh":"氯苯类浓度"},{"_id":"6a5dc9adf1c10c8ce825abdf","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie pestycydów","methodology_en":"Pesticide concentration","parameters":[{"name":"heksachlorocykloheksan (suma izomerów α,β,γ,δ)"},{"name":"Zakres","range":"(0,002 – 0,050) μg/dm3"},{"name":"aldryna","range":"(0,002 – 0,050) μg/dm3"},{"name":"dieldryna","range":"(0,002 – 0,050) μg/dm3"},{"name":"endryna","range":"(0,002 – 0,050) μg/dm3"},{"name":"izodryna","range":"(0,002 – 0,050) μg/dm3"},{"name":"α-endosulfan","range":"(0,002 – 0,050) μg/dm3"},{"name":"β-endosulfan","range":"(0,002 – 0,050) μg/dm3"},{"name":"p,p-DDE","range":"(0,002 – 0,050) μg/dm3"},{"name":"p,p-DDD","range":"(0,002 – 0,050) μg/dm3"},{"name":"p,p-DDT","range":"(0,002 – 0,050) μg/dm3"},{"name":"o,p-DDT","range":"(0,002 – 0,050) μg/dm3"},{"name":"alachlor","range":"(0,005 – 0,050) μg/dm3"},{"name":"trifluralina","range":"(0,002 – 0,050) μg/dm3"},{"name":"chlorfenwinfos","range":"(0,005 – 0,050) μg/dm3"},{"name":"chlorpiryfos etylowy","range":"(0,002 – 0,050) μg/dm3"}],"parameters_en":[{"name":"hexachlorocyclohexane (sum of α,β,γ,δ isomers)"},{"name":"Range","range":"(0,002 – 0,050) μg/dm3"},{"name":"aldrin","range":"(0,002 – 0,050) μg/dm3"},{"name":"dieldrin","range":"(0,002 – 0,050) μg/dm3"},{"name":"endrin","range":"(0,002 – 0,050) μg/dm3"},{"name":"isodrin","range":"(0,002 – 0,050) μg/dm3"},{"name":"α-endosulfan","range":"(0,002 – 0,050) μg/dm3"},{"name":"β-endosulfan","range":"(0,002 – 0,050) μg/dm3"},{"name":"p,p-DDE","range":"(0,002 – 0,050) μg/dm3"},{"name":"p,p-DDD","range":"(0,002 – 0,050) μg/dm3"},{"name":"p,p-DDT","range":"(0,002 – 0,050) μg/dm3"},{"name":"o,p-DDT","range":"(0,002 – 0,050) μg/dm3"},{"name":"alachlor","range":"(0,005 – 0,050) μg/dm3"},{"name":"trifluralin","range":"(0,002 – 0,050) μg/dm3"},{"name":"chlorfenvinphos","range":"(0,005 – 0,050) μg/dm3"},{"name":"chlorpyrifos-ethyl","range":"(0,002 – 0,050) μg/dm3"}],"technique":"Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","techniques":["Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)"],"technique_en":"Gas chromatography with electron capture detection (GC-ECD)","computed":[],"computed_en":[],"activity":"Stężenie pestycydów\nZakres:\nheksachlorocykloheksan (suma izomerów α,β,γ,δ)\nZakres (0,002 – 0,050) μg/dm3\naldryna (0,002 – 0,050) μg/dm3\ndieldryna (0,002 – 0,050) μg/dm3\nendryna (0,002 – 0,050) μg/dm3\nizodryna (0,002 – 0,050) μg/dm3\nα-endosulfan (0,002 – 0,050) μg/dm3\nβ-endosulfan (0,002 – 0,050) μg/dm3\np,p-DDE (0,002 – 0,050) μg/dm3\np,p-DDD (0,002 – 0,050) μg/dm3\np,p-DDT (0,002 – 0,050) μg/dm3\no,p-DDT (0,002 – 0,050) μg/dm3\nalachlor (0,005 – 0,050) μg/dm3\ntrifluralina (0,002 – 0,050) μg/dm3\nchlorfenwinfos (0,005 – 0,050) μg/dm3\nchlorpiryfos etylowy (0,002 – 0,050) μg/dm3\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","reference":"PN-EN ISO 6468:2002","norm_bases":["PN-EN ISO 6468:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie pestycydów\nZakres:\nheksachlorocykloheksan (suma izomerów α,β,γ,δ)\nZakres (0,002 – 0,050) μg/dm3\naldryna (0,002 – 0,050) μg/dm3\ndieldryna (0,002 – 0,050) μg/dm3\nendryna (0,002 – 0,050) μg/dm3\nizodryna (0,002 – 0,050) μg/dm3\nα-endosulfan (0,002 – 0,050) μg/dm3\nβ-endosulfan (0,002 – 0,050) μg/dm3\np,p-DDE (0,002 – 0,050) μg/dm3\np,p-DDD (0,002 – 0,050) μg/dm3\np,p-DDT (0,002 – 0,050) μg/dm3\no,p-DDT (0,002 – 0,050) μg/dm3\nalachlor (0,005 – 0,050) μg/dm3\ntrifluralina (0,002 – 0,050) μg/dm3\nchlorfenwinfos (0,005 – 0,050) μg/dm3\nchlorpiryfos etylowy (0,002 – 0,050) μg/dm3\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) PN-EN ISO 6468:2002 Woda, Scieki Stezenie pestycydow\nZakres:\nheksachlorocykloheksan (suma izomerow α,β,γ,δ)\nZakres (0,002 – 0,050) μg/dm3\naldryna (0,002 – 0,050) μg/dm3\ndieldryna (0,002 – 0,050) μg/dm3\nendryna (0,002 – 0,050) μg/dm3\nizodryna (0,002 – 0,050) μg/dm3\nα-endosulfan (0,002 – 0,050) μg/dm3\nβ-endosulfan (0,002 – 0,050) μg/dm3\np,p-DDE (0,002 – 0,050) μg/dm3\np,p-DDD (0,002 – 0,050) μg/dm3\np,p-DDT (0,002 – 0,050) μg/dm3\no,p-DDT (0,002 – 0,050) μg/dm3\nalachlor (0,005 – 0,050) μg/dm3\ntrifluralina (0,002 – 0,050) μg/dm3\nchlorfenwinfos (0,005 – 0,050) μg/dm3\nchlorpiryfos etylowy (0,002 – 0,050) μg/dm3\nMetoda chromatografii gazowej z detekcja wychwytu elektronow (GC-ECD) PN-EN ISO 6468:2002","categories":["water"],"row_index":78,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Pesticide concentration Gas chromatography with electron capture detection (GC-ECD) hexachlorocyclohexane (sum of α,β,γ,δ isomers) Range aldrin dieldrin endrin isodrin α-endosulfan β-endosulfan p,p-DDE p,p-DDD p,p-DDT o,p-DDT alachlor trifluralin chlorfenvinphos chlorpyrifos-ethyl PN-EN ISO 6468:2002","methodology_zh":"农药浓度","parameters_zh":[{"name":"heksachlorocykloheksan (suma izomerów α,β,γ,δ)"},{"name":"范围","range":"(0,002 – 0,050) μg/dm3"},{"name":"艾氏剂","range":"(0,002 – 0,050) μg/dm3"},{"name":"狄氏剂","range":"(0,002 – 0,050) μg/dm3"},{"name":"异狄氏剂","range":"(0,002 – 0,050) μg/dm3"},{"name":"异艾氏剂","range":"(0,002 – 0,050) μg/dm3"},{"name":"α-endosulfan","range":"(0,002 – 0,050) μg/dm3"},{"name":"β-endosulfan","range":"(0,002 – 0,050) μg/dm3"},{"name":"p,p-滴滴伊","range":"(0,002 – 0,050) μg/dm3"},{"name":"p,p-滴滴滴","range":"(0,002 – 0,050) μg/dm3"},{"name":"p,p-滴滴涕","range":"(0,002 – 0,050) μg/dm3"},{"name":"o,p-滴滴涕","range":"(0,002 – 0,050) μg/dm3"},{"name":"alachlor","range":"(0,005 – 0,050) μg/dm3"},{"name":"氟乐灵","range":"(0,002 – 0,050) μg/dm3"},{"name":"毒虫畏","range":"(0,005 – 0,050) μg/dm3"},{"name":"chlorpiryfos etylowy","range":"(0,002 – 0,050) μg/dm3"}],"search_zh":"水、污水 农药浓度 气相色谱-电子捕获检测法（GC-ECD） 范围 艾氏剂 狄氏剂 异狄氏剂 异艾氏剂 p,p-滴滴伊 p,p-滴滴滴 p,p-滴滴涕 o,p-滴滴涕 氟乐灵 毒虫畏 PN-EN ISO 6468:2002","technique_zh":"气相色谱-电子捕获检测法（GC-ECD）","test_object_zh":"水、污水"},{"_id":"6a5dc9adf1c10c8ce825abe0","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie chlorków","methodology_en":"Chloride concentration","parameters":[{"name":"Zakres","range":"(5,00 – 1000) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(5,00 – 1000) mg/dm3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie chlorków\nZakres (5,00 – 1000) mg/dm3\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie chlorków\nZakres (5,00 – 1000) mg/dm3\nMetoda miareczkowa PN-ISO 9297:1994 Woda, Scieki Stezenie chlorkow\nZakres (5,00 – 1000) mg/dm3\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":79,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Chloride concentration Titrimetric method Range PN-ISO 9297:1994","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,00 – 1000) mg/dm3"}],"search_zh":"水、污水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水、污水"},{"_id":"6a5dc9adf1c10c8ce825abe1","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie rtęci","methodology_en":"Mercury concentration","parameters":[{"name":"Zakres","range":"(15,0 – 500) ng/dm3"}],"parameters_en":[{"name":"Range","range":"(15,0 – 500) ng/dm3"}],"technique":"Metoda atomowej spektrometrii fluorescencyjnej (AFS)","techniques":["Metoda atomowej spektrometrii fluorescencyjnej (AFS)"],"technique_en":"Atomic fluorescence spectrometry (AFS)","computed":[],"computed_en":[],"activity":"Stężenie rtęci\nZakres (15,0 – 500) ng/dm3\nMetoda atomowej spektrometrii fluorescencyjnej (AFS)","reference":"PN-EN ISO 17852:2009","norm_bases":["PN-EN ISO 17852:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie rtęci\nZakres (15,0 – 500) ng/dm3\nMetoda atomowej spektrometrii fluorescencyjnej (AFS) PN-EN ISO 17852:2009 Woda Stezenie rteci\nZakres (15,0 – 500) ng/dm3\nMetoda atomowej spektrometrii fluorescencyjnej (AFS) PN-EN ISO 17852:2009","categories":["water"],"row_index":80,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Mercury concentration Atomic fluorescence spectrometry (AFS) Range PN-EN ISO 17852:2009","methodology_zh":"汞浓度","parameters_zh":[{"name":"范围","range":"(15,0 – 500) ng/dm3"}],"search_zh":"水 汞浓度 原子荧光光谱法（AFS） 范围 PN-EN ISO 17852:2009","test_object_zh":"水","technique_zh":"原子荧光光谱法（AFS）"},{"_id":"6a5dc9adf1c10c8ce825abe2","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie chromu sześciowartościowego","methodology_en":"Hexavalent chromium concentration","parameters":[{"name":"Zakres","range":"(0,0050 – 1,00) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,0050 – 1,00) mg/dm3"}],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","computed":[],"computed_en":[],"activity":"Stężenie chromu sześciowartościowego\nZakres (0,0050 – 1,00) mg/dm3\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"PB-062/WA wydanie 2 z dnia 15.07.2019 r.","norm_bases":["PB-062/WA wydanie 2 z dnia 15.07.2019 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie chromu sześciowartościowego\nZakres (0,0050 – 1,00) mg/dm3\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) PB-062/WA wydanie 2 z dnia 15.07.2019 r. Woda Stezenie chromu szesciowartosciowego\nZakres (0,0050 – 1,00) mg/dm3\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) PB-062/WA wydanie 2 z dnia 15.07.2019 r.","categories":["water"],"row_index":81,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Hexavalent chromium concentration Inductively coupled plasma mass spectrometry (ICP-MS) Range PB-062/WA wydanie 2 z dnia 15.07.2019 r.","parameters_zh":[{"name":"范围","range":"(0,0050 – 1,00) mg/dm3"}],"search_zh":"水 六价铬浓度 电感耦合等离子体质谱法（ICP-MS） 范围 PB-062/WA wydanie 2 z dnia 15.07.2019 r.","technique_zh":"电感耦合等离子体质谱法（ICP-MS）","test_object_zh":"水","methodology_zh":"六价铬浓度"},{"_id":"6a5dc9adf1c10c8ce825abe3","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie fosforanów","methodology_en":"Phosphate concentration","parameters":[{"name":"Zakres","range":"(0,06 – 14,0) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,06 – 14,0) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie fosforanów\nZakres (0,06 – 14,0) mg/dm3\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie fosforanów\nZakres (0,06 – 14,0) mg/dm3\nMetoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010 Woda Stezenie fosforanow\nZakres (0,06 – 14,0) mg/dm3\nMetoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010","categories":["water"],"row_index":82,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Phosphate concentration Spectrophotometric method Range PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010","parameters_zh":[{"name":"范围","range":"(0,06 – 14,0) mg/dm3"}],"search_zh":"水 磷酸盐浓度 分光光度法 范围 PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水","methodology_zh":"磷酸盐浓度"},{"_id":"6a5dc9adf1c10c8ce825abe4","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie ortofosforanów","methodology_en":"Orthophosphate concentration","parameters":[{"name":"Zakres","range":"(0,10 – 14) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,10 – 14) mg/dm3"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"technique_en":"Ion chromatography with conductometric detection (IC-CD)","computed":[],"computed_en":[],"activity":"Stężenie ortofosforanów\nZakres (0,10 – 14) mg/dm3\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie ortofosforanów\nZakres (0,10 – 14) mg/dm3\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Woda Stezenie ortofosforanow\nZakres (0,10 – 14) mg/dm3\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":83,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Orthophosphate concentration Ion chromatography with conductometric detection (IC-CD) Range PN-EN ISO 10304-1:2009+AC:2012","parameters_zh":[{"name":"范围","range":"(0,10 – 14) mg/dm3"}],"search_zh":"水 正磷酸盐浓度 离子色谱-电导检测法（IC-CD） 范围 PN-EN ISO 10304-1:2009+AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水","methodology_zh":"正磷酸盐浓度"},{"_id":"6a5dc9adf1c10c8ce825abe5","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie rtęci","methodology_en":"Mercury concentration","parameters":[{"name":"Zakres","range":"(15,0 – 1000) ng/dm3"}],"parameters_en":[{"name":"Range","range":"(15,0 – 1000) ng/dm3"}],"technique":"Metoda atomowej spektrometrii fluorescencyjnej (AFS)","techniques":["Metoda atomowej spektrometrii fluorescencyjnej (AFS)"],"technique_en":"Atomic fluorescence spectrometry (AFS)","computed":[],"computed_en":[],"activity":"Stężenie rtęci\nZakres (15,0 – 1000) ng/dm3\nMetoda atomowej spektrometrii fluorescencyjnej (AFS)","reference":"PN-EN ISO 17852:2009","norm_bases":["PN-EN ISO 17852:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie rtęci\nZakres (15,0 – 1000) ng/dm3\nMetoda atomowej spektrometrii fluorescencyjnej (AFS) PN-EN ISO 17852:2009 Scieki Stezenie rteci\nZakres (15,0 – 1000) ng/dm3\nMetoda atomowej spektrometrii fluorescencyjnej (AFS) PN-EN ISO 17852:2009","categories":["water"],"row_index":84,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Mercury concentration Atomic fluorescence spectrometry (AFS) Range PN-EN ISO 17852:2009","methodology_zh":"汞浓度","parameters_zh":[{"name":"范围","range":"(15,0 – 1000) ng/dm3"}],"search_zh":"污水 汞浓度 原子荧光光谱法（AFS） 范围 PN-EN ISO 17852:2009","test_object_zh":"污水","technique_zh":"原子荧光光谱法（AFS）"},{"_id":"6a5dc9adf1c10c8ce825abe6","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Obecność i liczba żywych jaj pasożytów jelitowych Ascaris sp.,Toxocara sp., Trichuris sp.,","methodology_en":"Presence and count of viable eggs of intestinal parasites Ascaris sp.,Toxocara sp., Trichuris sp.,","parameters":[{"name":"Zakres","range":"od 20 jaj/kg"}],"parameters_en":[{"name":"Range","range":"od 20 jaj/kg"}],"technique":"Metoda flotacji, mikroskopowa","techniques":["Metoda flotacji, mikroskopowa"],"technique_en":"Flotation method, microscopic","computed":[],"computed_en":[],"activity":"Obecność i liczba żywych jaj pasożytów jelitowych Ascaris sp.,Toxocara sp., Trichuris sp.,\nZakres od 20 jaj/kg\nMetoda flotacji, mikroskopowa","reference":"PB-09/CLB wydanie 1 z dnia 30.05.2022r.","norm_bases":["PB-09/CLB wydanie 1 z dnia 30.05.2022r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Obecność i liczba żywych jaj pasożytów jelitowych Ascaris sp.,Toxocara sp., Trichuris sp.,\nZakres od 20 jaj/kg\nMetoda flotacji, mikroskopowa PB-09/CLB wydanie 1 z dnia 30.05.2022r. Osady sciekowe Obecnosc i liczba zywych jaj pasozytow jelitowych Ascaris sp.,Toxocara sp., Trichuris sp.,\nZakres od 20 jaj/kg\nMetoda flotacji, mikroskopowa PB-09/CLB wydanie 1 z dnia 30.05.2022r.","categories":["water"],"row_index":85,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge Presence and count of viable eggs of intestinal parasites Ascaris sp.,Toxocara sp., Trichuris sp., Flotation method, microscopic Range PB-09/CLB wydanie 1 z dnia 30.05.2022r.","parameters_zh":[{"name":"范围","range":"od 20 jaj/kg"}],"search_zh":"污泥 肠道寄生虫 Ascaris sp.、Toxocara sp.、Trichuris sp. 活卵的检出与计数 浮选显微镜法 范围 PB-09/CLB wydanie 1 z dnia 30.05.2022r.","test_object_zh":"污泥","technique_zh":"浮选显微镜法","methodology_zh":"肠道寄生虫 Ascaris sp.、Toxocara sp.、Trichuris sp. 活卵的检出与计数"},{"_id":"6a5dc9adf1c10c8ce825abe7","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Zawartość metali","methodology_en":"Metal content","parameters":[{"name":"chrom","range":"(1,5 – 600) mg/kg"},{"name":"ołów","range":"(0,90 – 1200) mg/kg"},{"name":"miedź","range":"(1,2 – 800) mg/kg"},{"name":"kadm","range":"(0,25 – 1000) mg/kg"},{"name":"nikiel","range":"(0,90 – 600) mg/kg"},{"name":"cynk","range":"(9,0 – 2200) mg/kg"},{"name":"magnez","range":"(20,0 – 23 000) mg/kg"},{"name":"wapń","range":"(150 – 110 000) mg/kg"}],"parameters_en":[{"name":"chromium","range":"(1,5 – 600) mg/kg"},{"name":"lead","range":"(0,90 – 1200) mg/kg"},{"name":"copper","range":"(1,2 – 800) mg/kg"},{"name":"cadmium","range":"(0,25 – 1000) mg/kg"},{"name":"nickel","range":"(0,90 – 600) mg/kg"},{"name":"zinc","range":"(9,0 – 2200) mg/kg"},{"name":"magnesium","range":"(20,0 – 23 000) mg/kg"},{"name":"calcium","range":"(150 – 110 000) mg/kg"}],"technique":"Metoda spektometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","computed":[],"computed_en":[],"activity":"Zawartość metali\nZakres:\nchrom (1,5 – 600) mg/kg\nołów (0,90 – 1200) mg/kg\nmiedź (1,2 – 800) mg/kg\nkadm (0,25 – 1000) mg/kg\nnikiel (0,90 – 600) mg/kg\ncynk (9,0 – 2200) mg/kg\nmagnez (20,0 – 23 000) mg/kg\nwapń (150 – 110 000) mg/kg\nMetoda spektometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"PN-EN 13346:2002","norm_bases":["PN-EN 13346:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Zawartość metali\nZakres:\nchrom (1,5 – 600) mg/kg\nołów (0,90 – 1200) mg/kg\nmiedź (1,2 – 800) mg/kg\nkadm (0,25 – 1000) mg/kg\nnikiel (0,90 – 600) mg/kg\ncynk (9,0 – 2200) mg/kg\nmagnez (20,0 – 23 000) mg/kg\nwapń (150 – 110 000) mg/kg\nMetoda spektometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) PN-EN 13346:2002 Osady sciekowe Zawartosc metali\nZakres:\nchrom (1,5 – 600) mg/kg\nolow (0,90 – 1200) mg/kg\nmiedz (1,2 – 800) mg/kg\nkadm (0,25 – 1000) mg/kg\nnikiel (0,90 – 600) mg/kg\ncynk (9,0 – 2200) mg/kg\nmagnez (20,0 – 23 000) mg/kg\nwapn (150 – 110 000) mg/kg\nMetoda spektometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) PN-EN 13346:2002","categories":["materials","water"],"row_index":86,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge Metal content Inductively coupled plasma mass spectrometry (ICP-MS) chromium lead copper cadmium nickel zinc magnesium calcium PN-EN 13346:2002","parameters_zh":[{"name":"铬","range":"(1,5 – 600) mg/kg"},{"name":"铅","range":"(0,90 – 1200) mg/kg"},{"name":"铜","range":"(1,2 – 800) mg/kg"},{"name":"镉","range":"(0,25 – 1000) mg/kg"},{"name":"镍","range":"(0,90 – 600) mg/kg"},{"name":"锌","range":"(9,0 – 2200) mg/kg"},{"name":"镁","range":"(20,0 – 23 000) mg/kg"},{"name":"钙","range":"(150 – 110 000) mg/kg"}],"search_zh":"污泥 金属含量 电感耦合等离子体电离质谱法（ICP-MS） 铬 铅 铜 镉 镍 锌 镁 钙 PN-EN 13346:2002","test_object_zh":"污泥","methodology_zh":"金属含量","technique_zh":"电感耦合等离子体电离质谱法（ICP-MS）"},{"_id":"6a5dc9adf1c10c8ce825abe8","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Zawartość azotu Kjeldahla","methodology_en":"Kjeldahl nitrogen content","parameters":[{"name":"Zakres","range":"(0,10 – 10,0) %"},{"name":"Zakres","range":"(1,0 – 100) g/kg"}],"parameters_en":[{"name":"Range","range":"(0,10 – 10,0) %"},{"name":"Range","range":"(1,0 – 100) g/kg"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Zawartość azotu Kjeldahla\nZakres:\nZakres (0,10 – 10,0) %\nZakres (1,0 – 100) g/kg\nMetoda miareczkowa","reference":"PN-EN 13342:2002","norm_bases":["PN-EN 13342:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Zawartość azotu Kjeldahla\nZakres:\nZakres (0,10 – 10,0) %\nZakres (1,0 – 100) g/kg\nMetoda miareczkowa PN-EN 13342:2002 Osady sciekowe Zawartosc azotu Kjeldahla\nZakres:\nZakres (0,10 – 10,0) %\nZakres (1,0 – 100) g/kg\nMetoda miareczkowa PN-EN 13342:2002","categories":["water"],"row_index":87,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge Kjeldahl nitrogen content Titrimetric method Range Range PN-EN 13342:2002","parameters_zh":[{"name":"范围","range":"(0,10 – 10,0) %"},{"name":"范围","range":"(1,0 – 100) g/kg"}],"search_zh":"污泥 凯氏氮含量 滴定法 范围 范围 PN-EN 13342:2002","technique_zh":"滴定法","test_object_zh":"污泥","methodology_zh":"凯氏氮含量"},{"_id":"6a5dc9adf1c10c8ce825abe9","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Zawartość azotu amonowego","methodology_en":"Ammonium nitrogen content","parameters":[{"name":"Zakres","range":"(0,10 – 5,00) %"},{"name":"Zakres","range":"(1,00 – 50,0) g/kg"}],"parameters_en":[{"name":"Range","range":"(0,10 – 5,00) %"},{"name":"Range","range":"(1,00 – 50,0) g/kg"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Zawartość azotu amonowego\nZakres:\nZakres (0,10 – 5,00) %\nZakres (1,00 – 50,0) g/kg\nMetoda miareczkowa","reference":"PB-068/WA wydanie 2 z dnia 15.07.2019 r.","norm_bases":["PB-068/WA wydanie 2 z dnia 15.07.2019 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Zawartość azotu amonowego\nZakres:\nZakres (0,10 – 5,00) %\nZakres (1,00 – 50,0) g/kg\nMetoda miareczkowa PB-068/WA wydanie 2 z dnia 15.07.2019 r. Osady sciekowe Zawartosc azotu amonowego\nZakres:\nZakres (0,10 – 5,00) %\nZakres (1,00 – 50,0) g/kg\nMetoda miareczkowa PB-068/WA wydanie 2 z dnia 15.07.2019 r.","categories":["water"],"row_index":88,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge Ammonium nitrogen content Titrimetric method Range Range PB-068/WA wydanie 2 z dnia 15.07.2019 r.","parameters_zh":[{"name":"范围","range":"(0,10 – 5,00) %"},{"name":"范围","range":"(1,00 – 50,0) g/kg"}],"search_zh":"污泥 氨氮含量 滴定法 范围 范围 PB-068/WA wydanie 2 z dnia 15.07.2019 r.","technique_zh":"滴定法","test_object_zh":"污泥","methodology_zh":"氨氮含量"},{"_id":"6a5dc9adf1c10c8ce825abea","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Sucha pozostałość / zawartość wody","methodology_en":"Dry residue / water content","parameters":[{"name":"Zakres","range":"(0,1 – 99,9) %"}],"parameters_en":[{"name":"Range","range":"(0,1 – 99,9) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Sucha pozostałość / zawartość wody\nZakres (0,1 – 99,9) %\nMetoda wagowa","reference":"PN-EN 12880:2004","norm_bases":["PN-EN 12880:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Sucha pozostałość / zawartość wody\nZakres (0,1 – 99,9) %\nMetoda wagowa PN-EN 12880:2004 Osady sciekowe Sucha pozostalosc / zawartosc wody\nZakres (0,1 – 99,9) %\nMetoda wagowa PN-EN 12880:2004","categories":["water"],"row_index":89,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge Dry residue / water content Gravimetric method Range PN-EN 12880:2004","parameters_zh":[{"name":"范围","range":"(0,1 – 99,9) %"}],"search_zh":"污泥 干残渣/水分含量 重量法 范围 PN-EN 12880:2004","technique_zh":"重量法","test_object_zh":"污泥","methodology_zh":"干残渣/水分含量"},{"_id":"6a5dc9adf1c10c8ce825abeb","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Zawartość fosforu ogólnego","methodology_en":"Total phosphorus content","parameters":[{"name":"Zakres","range":"(0,3 – 6,0) %"},{"name":"Zakres","range":"(3,0 – 60) g/kg"}],"parameters_en":[{"name":"Range","range":"(0,3 – 6,0) %"},{"name":"Range","range":"(3,0 – 60) g/kg"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Zawartość fosforu ogólnego\nZakres:\nZakres (0,3 – 6,0) %\nZakres (3,0 – 60) g/kg\nMetoda spektrofotometryczna","reference":"PN-EN 16174:2012 | PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010 pkt. 7","norm_bases":["PN-EN 16174:2012","PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010 pkt. 7"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Zawartość fosforu ogólnego\nZakres:\nZakres (0,3 – 6,0) %\nZakres (3,0 – 60) g/kg\nMetoda spektrofotometryczna PN-EN 16174:2012 | PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010 pkt. 7 Osady sciekowe Zawartosc fosforu ogolnego\nZakres:\nZakres (0,3 – 6,0) %\nZakres (3,0 – 60) g/kg\nMetoda spektrofotometryczna PN-EN 16174:2012 | PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010 pkt. 7","categories":["water"],"row_index":90,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge Total phosphorus content Spectrophotometric method Range Range PN-EN 16174:2012 | PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010 pkt. 7","parameters_zh":[{"name":"范围","range":"(0,3 – 6,0) %"},{"name":"范围","range":"(3,0 – 60) g/kg"}],"search_zh":"污泥 总磷含量 分光光度法 范围 范围 PN-EN 16174:2012 | PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010 pkt. 7","technique_zh":"分光光度法","test_object_zh":"污泥","methodology_zh":"总磷含量"},{"_id":"6a5dc9adf1c10c8ce825abec","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Zawartość fosforu ogólnego","methodology_en":"Total phosphorus content","parameters":[{"name":"Zakres","range":"(0,3 – 8,0) %"},{"name":"Zakres","range":"(3,0 – 80) g/kg"}],"parameters_en":[{"name":"Range","range":"(0,3 – 8,0) %"},{"name":"Range","range":"(3,0 – 80) g/kg"}],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","computed":[],"computed_en":[],"activity":"Zawartość fosforu ogólnego\nZakres:\nZakres (0,3 – 8,0) %\nZakres (3,0 – 80) g/kg\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"PN-EN 16171:2017-02","norm_bases":["PN-EN 16171:2017-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Zawartość fosforu ogólnego\nZakres:\nZakres (0,3 – 8,0) %\nZakres (3,0 – 80) g/kg\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) PN-EN 16171:2017-02 Osady sciekowe Zawartosc fosforu ogolnego\nZakres:\nZakres (0,3 – 8,0) %\nZakres (3,0 – 80) g/kg\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) PN-EN 16171:2017-02","categories":["water"],"row_index":91,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge Total phosphorus content Inductively coupled plasma mass spectrometry (ICP-MS) Range Range PN-EN 16171:2017-02","parameters_zh":[{"name":"范围","range":"(0,3 – 8,0) %"},{"name":"范围","range":"(3,0 – 80) g/kg"}],"search_zh":"污泥 总磷含量 电感耦合等离子体质谱法（ICP-MS） 范围 范围 PN-EN 16171:2017-02","technique_zh":"电感耦合等离子体质谱法（ICP-MS）","test_object_zh":"污泥","methodology_zh":"总磷含量"},{"_id":"6a5dc9adf1c10c8ce825abed","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Zawartość metali","methodology_en":"Metal content","parameters":[{"name":"arsen","range":"(2 – 4000) mg/kg"},{"name":"bar","range":"(3,0 – 400) mg/kg"},{"name":"chrom","range":"(1,5 – 400) mg/kg"},{"name":"cynk","range":"(9,0 – 4000) mg/kg"},{"name":"kadm","range":"(0,10 – 400) mg/kg"},{"name":"miedź","range":"(0,90 – 400) mg/kg"},{"name":"molibden","range":"(0,50 – 400) mg/kg"},{"name":"ołów","range":"(0,90 – 400) mg/kg"},{"name":"nikiel","range":"(0,90 – 400) mg/kg"},{"name":"kobalt","range":"(0,2 – 500 ) mg/kg"},{"name":"cyna","range":"(1,5 – 500 ) mg/kg"}],"parameters_en":[{"name":"arsenic","range":"(2 – 4000) mg/kg"},{"name":"barium","range":"(3,0 – 400) mg/kg"},{"name":"chromium","range":"(1,5 – 400) mg/kg"},{"name":"zinc","range":"(9,0 – 4000) mg/kg"},{"name":"cadmium","range":"(0,10 – 400) mg/kg"},{"name":"copper","range":"(0,90 – 400) mg/kg"},{"name":"molybdenum","range":"(0,50 – 400) mg/kg"},{"name":"lead","range":"(0,90 – 400) mg/kg"},{"name":"nickel","range":"(0,90 – 400) mg/kg"},{"name":"cobalt","range":"(0,2 – 500 ) mg/kg"},{"name":"tin","range":"(1,5 – 500 ) mg/kg"}],"technique":"Metoda spektometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","computed":[],"computed_en":[],"activity":"Zawartość metali\nZakres:\narsen (2 – 4000) mg/kg\nbar (3,0 – 400) mg/kg\nchrom (1,5 – 400) mg/kg\ncynk (9,0 – 4000) mg/kg\nkadm (0,10 – 400) mg/kg\nmiedź (0,90 – 400) mg/kg\nmolibden (0,50 – 400) mg/kg\nołów (0,90 – 400) mg/kg\nnikiel (0,90 – 400) mg/kg\nkobalt (0,2 – 500 ) mg/kg\ncyna (1,5 – 500 ) mg/kg\nMetoda spektometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"PB-059/WA wydanie 4 z dnia 15.07.2019 r.","norm_bases":["PB-059/WA wydanie 4 z dnia 15.07.2019 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Zawartość metali\nZakres:\narsen (2 – 4000) mg/kg\nbar (3,0 – 400) mg/kg\nchrom (1,5 – 400) mg/kg\ncynk (9,0 – 4000) mg/kg\nkadm (0,10 – 400) mg/kg\nmiedź (0,90 – 400) mg/kg\nmolibden (0,50 – 400) mg/kg\nołów (0,90 – 400) mg/kg\nnikiel (0,90 – 400) mg/kg\nkobalt (0,2 – 500 ) mg/kg\ncyna (1,5 – 500 ) mg/kg\nMetoda spektometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) PB-059/WA wydanie 4 z dnia 15.07.2019 r. Gleba Zawartosc metali\nZakres:\narsen (2 – 4000) mg/kg\nbar (3,0 – 400) mg/kg\nchrom (1,5 – 400) mg/kg\ncynk (9,0 – 4000) mg/kg\nkadm (0,10 – 400) mg/kg\nmiedz (0,90 – 400) mg/kg\nmolibden (0,50 – 400) mg/kg\nolow (0,90 – 400) mg/kg\nnikiel (0,90 – 400) mg/kg\nkobalt (0,2 – 500 ) mg/kg\ncyna (1,5 – 500 ) mg/kg\nMetoda spektometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) PB-059/WA wydanie 4 z dnia 15.07.2019 r.","categories":["materials","environment"],"row_index":92,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Soil Metal content Inductively coupled plasma mass spectrometry (ICP-MS) arsenic barium chromium zinc cadmium copper molybdenum lead nickel cobalt tin PB-059/WA wydanie 4 z dnia 15.07.2019 r.","parameters_zh":[{"name":"砷","range":"(2 – 4000) mg/kg"},{"name":"钡","range":"(3,0 – 400) mg/kg"},{"name":"铬","range":"(1,5 – 400) mg/kg"},{"name":"锌","range":"(9,0 – 4000) mg/kg"},{"name":"镉","range":"(0,10 – 400) mg/kg"},{"name":"铜","range":"(0,90 – 400) mg/kg"},{"name":"钼","range":"(0,50 – 400) mg/kg"},{"name":"铅","range":"(0,90 – 400) mg/kg"},{"name":"镍","range":"(0,90 – 400) mg/kg"},{"name":"钴","range":"(0,2 – 500 ) mg/kg"},{"name":"锡","range":"(1,5 – 500 ) mg/kg"}],"search_zh":"土壤 金属含量 电感耦合等离子体电离质谱法（ICP-MS） 砷 钡 铬 锌 镉 铜 钼 铅 镍 钴 锡 PB-059/WA wydanie 4 z dnia 15.07.2019 r.","test_object_zh":"土壤","methodology_zh":"金属含量","technique_zh":"电感耦合等离子体电离质谱法（ICP-MS）"},{"_id":"6a5dc9adf1c10c8ce825abee","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Zawartość ogólnego węgla organicznego (TOC)","methodology_en":"Total organic carbon (TOC) content","parameters":[{"name":"Zakres","range":"(4 000 – 400 000) mg/kg"},{"name":"Zakres","range":"(0,400 – 40,0) %"}],"parameters_en":[{"name":"Range","range":"(4 000 – 400 000) mg/kg"},{"name":"Range","range":"(0,400 – 40,0) %"}],"technique":"Metoda spektometrii w zakresie podczerwieni (IR)","techniques":["Metoda spektometrii w zakresie podczerwieni (IR)"],"technique_en":"Infrared spectrometry method (IR)","computed":[],"computed_en":[],"activity":"Zawartość ogólnego węgla organicznego (TOC)\nZakres:\nZakres (4 000 – 400 000) mg/kg\nZakres (0,400 – 40,0) %\nMetoda spektometrii w zakresie podczerwieni (IR)","reference":"PN-EN 10694:2002 z wyłączeniem punktu 8.2.1","norm_bases":["PN-EN 10694:2002 z wyłączeniem punktu 8.2.1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Zawartość ogólnego węgla organicznego (TOC)\nZakres:\nZakres (4 000 – 400 000) mg/kg\nZakres (0,400 – 40,0) %\nMetoda spektometrii w zakresie podczerwieni (IR) PN-EN 10694:2002 z wyłączeniem punktu 8.2.1 Gleba Zawartosc ogolnego wegla organicznego (TOC)\nZakres:\nZakres (4 000 – 400 000) mg/kg\nZakres (0,400 – 40,0) %\nMetoda spektometrii w zakresie podczerwieni (IR) PN-EN 10694:2002 z wylaczeniem punktu 8.2.1","categories":["environment"],"row_index":93,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Soil Total organic carbon (TOC) content Infrared spectrometry method (IR) Range Range PN-EN 10694:2002 z wyłączeniem punktu 8.2.1","parameters_zh":[{"name":"范围","range":"(4 000 – 400 000) mg/kg"},{"name":"范围","range":"(0,400 – 40,0) %"}],"search_zh":"土壤 总有机碳（TOC）含量 范围 范围 PN-EN 10694:2002 z wyłączeniem punktu 8.2.1","test_object_zh":"土壤","methodology_zh":"总有机碳（TOC）含量"},{"_id":"6a5dc9adf1c10c8ce825abef","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Zawartość benzyn (węglowodory C6-C12) / suma węglowodorów C6-C12, składników frakcji benzyn","methodology_en":"Petrol content (C6-C12 hydrocarbons) / sum of C6-C12 hydrocarbons, components of the petrol fraction","parameters":[{"name":"Zakres","range":"(1,0 – 500) mg/kg"}],"parameters_en":[{"name":"Range","range":"(1,0 – 500) mg/kg"}],"technique":"Metoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją spektrometrii mas (P&T GC-MS)","techniques":["Metoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją spektrometrii mas (P&T GC-MS)"],"technique_en":"Gas chromatography with purge and trap technique (Purge&Trap) and mass spectrometry detection (P&T GC-MS)","computed":[],"computed_en":[],"activity":"Zawartość benzyn (węglowodory C6-C12) / suma węglowodorów C6-C12, składników frakcji benzyn\nZakres (1,0 – 500) mg/kg\nMetoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją spektrometrii mas (P&T GC-MS)","reference":"PB-067/WA wydanie 3 z 01.07.2023","norm_bases":["PB-067/WA wydanie 3 z 01.07.2023"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Zawartość benzyn (węglowodory C6-C12) / suma węglowodorów C6-C12, składników frakcji benzyn\nZakres (1,0 – 500) mg/kg\nMetoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją spektrometrii mas (P&T GC-MS) PB-067/WA wydanie 3 z 01.07.2023 Gleba Zawartosc benzyn (weglowodory C6-C12) / suma weglowodorow C6-C12, skladnikow frakcji benzyn\nZakres (1,0 – 500) mg/kg\nMetoda chromatografii gazowej z technika wylapywania i wyplukiwania (Purge&Trap) i detekcja spektrometrii mas (P&T GC-MS) PB-067/WA wydanie 3 z 01.07.2023","categories":["environment"],"row_index":94,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Soil Petrol content (C6-C12 hydrocarbons) / sum of C6-C12 hydrocarbons, components of the petrol fraction Gas chromatography with purge and trap technique (Purge&Trap) and mass spectrometry detection (P&T GC-MS) Range PB-067/WA wydanie 3 z 01.07.2023","parameters_zh":[{"name":"范围","range":"(1,0 – 500) mg/kg"}],"search_zh":"土壤 范围 PB-067/WA wydanie 3 z 01.07.2023","test_object_zh":"土壤"},{"_id":"6a5dc9adf1c10c8ce825abf0","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Zawartość suchej masy / zawartość wody","methodology_en":"Dry matter content / water content","parameters":[{"name":"Zakres","range":"(0,1 – 99,9) %"}],"parameters_en":[{"name":"Range","range":"(0,1 – 99,9) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość suchej masy / zawartość wody\nZakres (0,1 – 99,9) %\nMetoda wagowa","reference":"PN-ISO 11465:1999","norm_bases":["PN-ISO 11465:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Zawartość suchej masy / zawartość wody\nZakres (0,1 – 99,9) %\nMetoda wagowa PN-ISO 11465:1999 Gleba Zawartosc suchej masy / zawartosc wody\nZakres (0,1 – 99,9) %\nMetoda wagowa PN-ISO 11465:1999","categories":["water","environment"],"row_index":95,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Soil Dry matter content / water content Gravimetric method Range PN-ISO 11465:1999","parameters_zh":[{"name":"范围","range":"(0,1 – 99,9) %"}],"search_zh":"土壤 干物质含量/水分含量 重量法 范围 PN-ISO 11465:1999","technique_zh":"重量法","test_object_zh":"土壤","methodology_zh":"干物质含量/水分含量"},{"_id":"6a5dc9adf1c10c8ce825abf1","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"pH - w H2O","methodology_en":"pH - in H2O","parameters":[{"name":"Zakres","range":"3,0 – 10,0"},{"name":"Zakres","range":"3,0 – 10,0"}],"parameters_en":[{"name":"Range","range":"3,0 – 10,0"},{"name":"Range","range":"3,0 – 10,0"}],"technique":"Metoda potencjometryczna pH - w KCl; Metoda potencjometryczna","techniques":["Metoda potencjometryczna pH - w KCl","Metoda potencjometryczna"],"technique_en":"Potentiometric method pH - in KCl; Potentiometric method","computed":[],"computed_en":[],"activity":"pH - w H2O\nZakres:\nZakres 3,0 – 10,0\nZakres 3,0 – 10,0\nMetoda potencjometryczna pH - w KCl; Metoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba pH - w H2O\nZakres:\nZakres 3,0 – 10,0\nZakres 3,0 – 10,0\nMetoda potencjometryczna pH - w KCl; Metoda potencjometryczna PN-EN ISO 10390:2022-09 Gleba pH - w H2O\nZakres:\nZakres 3,0 – 10,0\nZakres 3,0 – 10,0\nMetoda potencjometryczna pH - w KCl; Metoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["environment"],"row_index":96,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Soil pH - in H2O Potentiometric method pH - in KCl; Potentiometric method Range Range PN-EN ISO 10390:2022-09","parameters_zh":[{"name":"范围","range":"3,0 – 10,0"},{"name":"范围","range":"3,0 – 10,0"}],"search_zh":"土壤 pH - 于 H2O 中 范围 范围 PN-EN ISO 10390:2022-09","test_object_zh":"土壤","methodology_zh":"pH - 于 H2O 中"},{"_id":"6a5dc9adf1c10c8ce825abf2","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Gleba, Osady ściekowe","test_object_en":"Soil, Sewage sludge","methodology":"Zawartość rtęci","methodology_en":"Mercury content","parameters":[{"name":"Zakres","range":"(0,040 – 6,00) mg/kg"}],"parameters_en":[{"name":"Range","range":"(0,040 – 6,00) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","techniques":["Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji"],"technique_en":"Atomic absorption spectrometry with amalgamation technique","computed":[],"computed_en":[],"activity":"Zawartość rtęci\nZakres (0,040 – 6,00) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","reference":"PB-026/WA wydanie 7 z dnia 15.07.2019 r.","norm_bases":["PB-026/WA wydanie 7 z dnia 15.07.2019 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba, Osady ściekowe Zawartość rtęci\nZakres (0,040 – 6,00) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji PB-026/WA wydanie 7 z dnia 15.07.2019 r. Gleba, Osady sciekowe Zawartosc rteci\nZakres (0,040 – 6,00) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z technika amalgamacji PB-026/WA wydanie 7 z dnia 15.07.2019 r.","categories":["water","environment"],"row_index":97,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Soil, Sewage sludge Mercury content Atomic absorption spectrometry with amalgamation technique Range PB-026/WA wydanie 7 z dnia 15.07.2019 r.","methodology_zh":"汞含量","parameters_zh":[{"name":"范围","range":"(0,040 – 6,00) mg/kg"}],"search_zh":"土壤、污泥 汞含量 原子吸收光谱法（汞齐化技术） 范围 PB-026/WA wydanie 7 z dnia 15.07.2019 r.","technique_zh":"原子吸收光谱法（汞齐化技术）","test_object_zh":"土壤、污泥"},{"_id":"6a5dc9adf1c10c8ce825abf3","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Środowisko ogólne: - próbki gazów odlotowych","test_object_en":"General environment: - waste gas samples","methodology":"Zawartość metali w pyle","methodology_en":"Metal content in dust","parameters":[{"name":"arsen","range":"(0,10 – 140) μg/próbkę"},{"name":"kadm","range":"(0,10 – 130) μg/próbkę"},{"name":"chrom","range":"(0,60 – 250) μg/próbkę"},{"name":"kobalt","range":"(0,20 – 25) μg/próbkę"},{"name":"miedź","range":"(4,0 – 500) μg/próbkę"},{"name":"mangan","range":"(0,70 – 300) μg/próbkę"},{"name":"nikiel","range":"(1,2 – 70) μg/próbkę"},{"name":"ołów","range":"(0,15 – 2300) μg/próbkę"},{"name":"tal","range":"(0,10 – 14) μg/próbkę"},{"name":"wanad","range":"(0,10 – 25) μg/próbkę"},{"name":"żelazo","range":"(40 – 6000) μg/próbkę"},{"name":"cynk","range":"(17 – 8000) μg/próbkę"}],"parameters_en":[{"name":"arsenic","range":"(0,10 – 140) μg/próbkę"},{"name":"cadmium","range":"(0,10 – 130) μg/próbkę"},{"name":"chromium","range":"(0,60 – 250) μg/próbkę"},{"name":"cobalt","range":"(0,20 – 25) μg/próbkę"},{"name":"copper","range":"(4,0 – 500) μg/próbkę"},{"name":"manganese","range":"(0,70 – 300) μg/próbkę"},{"name":"nickel","range":"(1,2 – 70) μg/próbkę"},{"name":"lead","range":"(0,15 – 2300) μg/próbkę"},{"name":"thallium","range":"(0,10 – 14) μg/próbkę"},{"name":"vanadium","range":"(0,10 – 25) μg/próbkę"},{"name":"iron","range":"(40 – 6000) μg/próbkę"},{"name":"zinc","range":"(17 – 8000) μg/próbkę"}],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","computed":[],"computed_en":[],"activity":"Zawartość metali w pyle\nZakres:\narsen (0,10 – 140) μg/próbkę\nkadm (0,10 – 130) μg/próbkę\nchrom (0,60 – 250) μg/próbkę\nkobalt (0,20 – 25) μg/próbkę\nmiedź (4,0 – 500) μg/próbkę\nmangan (0,70 – 300) μg/próbkę\nnikiel (1,2 – 70) μg/próbkę\nołów (0,15 – 2300) μg/próbkę\ntal (0,10 – 14) μg/próbkę\nwanad (0,10 – 25) μg/próbkę\nżelazo (40 – 6000) μg/próbkę\ncynk (17 – 8000) μg/próbkę\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"PN-EN 14385:2005","norm_bases":["PN-EN 14385:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne: - próbki gazów odlotowych Zawartość metali w pyle\nZakres:\narsen (0,10 – 140) μg/próbkę\nkadm (0,10 – 130) μg/próbkę\nchrom (0,60 – 250) μg/próbkę\nkobalt (0,20 – 25) μg/próbkę\nmiedź (4,0 – 500) μg/próbkę\nmangan (0,70 – 300) μg/próbkę\nnikiel (1,2 – 70) μg/próbkę\nołów (0,15 – 2300) μg/próbkę\ntal (0,10 – 14) μg/próbkę\nwanad (0,10 – 25) μg/próbkę\nżelazo (40 – 6000) μg/próbkę\ncynk (17 – 8000) μg/próbkę\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) PN-EN 14385:2005 Srodowisko ogolne: - probki gazow odlotowych Zawartosc metali w pyle\nZakres:\narsen (0,10 – 140) μg/probke\nkadm (0,10 – 130) μg/probke\nchrom (0,60 – 250) μg/probke\nkobalt (0,20 – 25) μg/probke\nmiedz (4,0 – 500) μg/probke\nmangan (0,70 – 300) μg/probke\nnikiel (1,2 – 70) μg/probke\nolow (0,15 – 2300) μg/probke\ntal (0,10 – 14) μg/probke\nwanad (0,10 – 25) μg/probke\nzelazo (40 – 6000) μg/probke\ncynk (17 – 8000) μg/probke\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) PN-EN 14385:2005","categories":["materials","environment"],"row_index":98,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"General environment: - waste gas samples Metal content in dust Inductively coupled plasma mass spectrometry (ICP-MS) arsenic cadmium chromium cobalt copper manganese nickel lead thallium vanadium iron zinc PN-EN 14385:2005","parameters_zh":[{"name":"砷","range":"(0,10 – 140) μg/próbkę"},{"name":"镉","range":"(0,10 – 130) μg/próbkę"},{"name":"铬","range":"(0,60 – 250) μg/próbkę"},{"name":"钴","range":"(0,20 – 25) μg/próbkę"},{"name":"铜","range":"(4,0 – 500) μg/próbkę"},{"name":"锰","range":"(0,70 – 300) μg/próbkę"},{"name":"镍","range":"(1,2 – 70) μg/próbkę"},{"name":"铅","range":"(0,15 – 2300) μg/próbkę"},{"name":"铊","range":"(0,10 – 14) μg/próbkę"},{"name":"钒","range":"(0,10 – 25) μg/próbkę"},{"name":"铁","range":"(40 – 6000) μg/próbkę"},{"name":"锌","range":"(17 – 8000) μg/próbkę"}],"search_zh":"电感耦合等离子体质谱法（ICP-MS） 砷 镉 铬 钴 铜 锰 镍 铅 铊 钒 铁 锌 PN-EN 14385:2005","technique_zh":"电感耦合等离子体质谱法（ICP-MS）"},{"_id":"6a5dc9adf1c10c8ce825abf4","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda powierzchniowa","test_object_en":"Surface water","methodology":"Stężenie chlorofilu a","methodology_en":"Chlorophyll a concentration","parameters":[{"name":"Zakres","range":"(1,1 – 300) μg/dm3"}],"parameters_en":[{"name":"Range","range":"(1,1 – 300) μg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie chlorofilu a\nZakres (1,1 – 300) μg/dm3\nMetoda spektrofotometryczna","reference":"PN-ISO 10260:2002","norm_bases":["PN-ISO 10260:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda powierzchniowa Stężenie chlorofilu a\nZakres (1,1 – 300) μg/dm3\nMetoda spektrofotometryczna PN-ISO 10260:2002 Woda powierzchniowa Stezenie chlorofilu a\nZakres (1,1 – 300) μg/dm3\nMetoda spektrofotometryczna PN-ISO 10260:2002","categories":["water"],"row_index":99,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Surface water Chlorophyll a concentration Spectrophotometric method Range PN-ISO 10260:2002","parameters_zh":[{"name":"范围","range":"(1,1 – 300) μg/dm3"}],"search_zh":"地表水 分光光度法 范围 PN-ISO 10260:2002","technique_zh":"分光光度法","test_object_zh":"地表水"},{"_id":"6a5dc9adf1c10c8ce825abf5","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Indeks nadmanganianowy","methodology_en":"Permanganate index","parameters":[{"name":"Zakres","range":"(1,3 – 200) mg/dm3 O2"}],"parameters_en":[{"name":"Range","range":"(1,3 – 200) mg/dm3 O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Indeks nadmanganianowy\nZakres (1,3 – 200) mg/dm3 O2\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Indeks nadmanganianowy\nZakres (1,3 – 200) mg/dm3 O2\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda, Scieki Indeks nadmanganianowy\nZakres (1,3 – 200) mg/dm3 O2\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":100,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Permanganate index Titrimetric method Range PN-EN ISO 8467:2001","methodology_zh":"高锰酸盐指数","parameters_zh":[{"name":"范围","range":"(1,3 – 200) mg/dm3 O2"}],"search_zh":"水、污水 高锰酸盐指数 滴定法 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"水、污水"},{"_id":"6a5dc9adf1c10c8ce825abf6","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie chlorków","methodology_en":"Chloride concentration","parameters":[{"name":"Zakres","range":"(5,00 – 2000) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(5,00 – 2000) mg/dm3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie chlorków\nZakres (5,00 – 2000) mg/dm3\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie chlorków\nZakres (5,00 – 2000) mg/dm3\nMetoda miareczkowa PN-ISO 9297:1994 Woda, Scieki Stezenie chlorkow\nZakres (5,00 – 2000) mg/dm3\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":101,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Chloride concentration Titrimetric method Range PN-ISO 9297:1994","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,00 – 2000) mg/dm3"}],"search_zh":"水、污水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水、污水"},{"_id":"6a5dc9adf1c10c8ce825abf7","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie siarczanów","methodology_en":"Sulfate concentration","parameters":[{"name":"Zakres","range":"(10,0 – 5000) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(10,0 – 5000) mg/dm3"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie siarczanów\nZakres (10,0 – 5000) mg/dm3\nMetoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie siarczanów\nZakres (10,0 – 5000) mg/dm3\nMetoda wagowa PN-ISO 9280:2002 Woda, Scieki Stezenie siarczanow\nZakres (10,0 – 5000) mg/dm3\nMetoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":102,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Sulfate concentration Gravimetric method Range PN-ISO 9280:2002","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(10,0 – 5000) mg/dm3"}],"search_zh":"水、污水 硫酸盐浓度 重量法 范围 PN-ISO 9280:2002","technique_zh":"重量法","test_object_zh":"水、污水"},{"_id":"6a5dc9adf1c10c8ce825abf8","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie azotu amonowego","methodology_en":"Ammonium nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,05 – 100) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,05 – 100) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego\nZakres (0,05 – 100) mg/dm3\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie azotu amonowego\nZakres (0,05 – 100) mg/dm3\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, Scieki Stezenie azotu amonowego\nZakres (0,05 – 100) mg/dm3\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":103,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Ammonium nitrogen concentration Spectrophotometric method Range PN-ISO 7150-1:2002","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,05 – 100) mg/dm3"}],"search_zh":"水、污水 氨氮浓度 分光光度法 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a5dc9adf1c10c8ce825abf9","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie azotu azotanowego","methodology_en":"Nitrate nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,04 – 100) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,04 – 100) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu azotanowego\nZakres (0,04 – 100) mg/dm3\nMetoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie azotu azotanowego\nZakres (0,04 – 100) mg/dm3\nMetoda spektrofotometryczna PN-82/C-04576/08 Woda, Scieki Stezenie azotu azotanowego\nZakres (0,04 – 100) mg/dm3\nMetoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":104,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Nitrate nitrogen concentration Spectrophotometric method Range PN-82/C-04576/08","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,04 – 100) mg/dm3"}],"search_zh":"水、污水 硝态氮浓度 分光光度法 范围 PN-82/C-04576/08","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a5dc9adf1c10c8ce825abfa","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie azotu Kjeldahla","methodology_en":"Kjeldahl nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,50 – 300) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,50 – 300) mg/dm3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie azotu Kjeldahla\nZakres (0,50 – 300) mg/dm3\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie azotu Kjeldahla\nZakres (0,50 – 300) mg/dm3\nMetoda miareczkowa PN-EN 25663:2001 Woda, Scieki Stezenie azotu Kjeldahla\nZakres (0,50 – 300) mg/dm3\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":105,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Kjeldahl nitrogen concentration Titrimetric method Range PN-EN 25663:2001","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(0,50 – 300) mg/dm3"}],"search_zh":"水、污水 凯氏氮浓度 滴定法 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"水、污水"},{"_id":"6a5dc9adf1c10c8ce825abfb","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie azotu ogólnego (z obliczeń)","methodology_en":"Total nitrogen concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PB-049/WA wydanie 3 z dnia 15.07.2019 r.","norm_bases":["PB-049/WA wydanie 3 z dnia 15.07.2019 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie azotu ogólnego (z obliczeń) PB-049/WA wydanie 3 z dnia 15.07.2019 r. Woda, Scieki Stezenie azotu ogolnego (z obliczen) PB-049/WA wydanie 3 z dnia 15.07.2019 r.","categories":["water"],"row_index":106,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Total nitrogen concentration (calculated) PB-049/WA wydanie 3 z dnia 15.07.2019 r.","methodology_zh":"总氮浓度（计算值）","search_zh":"水、污水 总氮浓度（计算值） PB-049/WA wydanie 3 z dnia 15.07.2019 r.","test_object_zh":"水、污水"},{"_id":"6a5dc9adf1c10c8ce825abfc","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Całkowite substancje rozpuszczone (TDS)","methodology_en":"Total dissolved solids (TDS)","parameters":[{"name":"Zakres","range":"(20,0 – 2000) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(20,0 – 2000) mg/dm3"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Całkowite substancje rozpuszczone (TDS)\nZakres (20,0 – 2000) mg/dm3\nMetoda wagowa","reference":"PN-EN 15216:2022-03","norm_bases":["PN-EN 15216:2022-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Całkowite substancje rozpuszczone (TDS)\nZakres (20,0 – 2000) mg/dm3\nMetoda wagowa PN-EN 15216:2022-03 Woda, Scieki Calkowite substancje rozpuszczone (TDS)\nZakres (20,0 – 2000) mg/dm3\nMetoda wagowa PN-EN 15216:2022-03","categories":["water"],"row_index":107,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Total dissolved solids (TDS) Gravimetric method Range PN-EN 15216:2022-03","parameters_zh":[{"name":"范围","range":"(20,0 – 2000) mg/dm3"}],"search_zh":"水、污水 溶解性总固体（TDS） 重量法 范围 PN-EN 15216:2022-03","technique_zh":"重量法","test_object_zh":"水、污水","methodology_zh":"溶解性总固体（TDS）"},{"_id":"6a5dc9adf1c10c8ce825abfd","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Twardość ogólna (z obliczeń)","methodology_en":"Total hardness (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Twardość ogólna (z obliczeń)","reference":"PB-060/WA wydanie 2 z dnia 15.07.2019 r.","norm_bases":["PB-060/WA wydanie 2 z dnia 15.07.2019 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Twardość ogólna (z obliczeń) PB-060/WA wydanie 2 z dnia 15.07.2019 r. Woda, Scieki Twardosc ogolna (z obliczen) PB-060/WA wydanie 2 z dnia 15.07.2019 r.","categories":["water"],"row_index":108,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Total hardness (calculated) PB-060/WA wydanie 2 z dnia 15.07.2019 r.","search_zh":"水、污水 总硬度（由计算得出） PB-060/WA wydanie 2 z dnia 15.07.2019 r.","test_object_zh":"水、污水","methodology_zh":"总硬度（由计算得出）"},{"_id":"6a5dc9adf1c10c8ce825abfe","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu","methodology_en":"Biochemical oxygen demand","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(1,0 – 6000) mg/dm3 O2"}],"parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(1,0 – 6000) mg/dm3 O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1,0 – 6000) mg/dm3 O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1,0 – 6000) mg/dm3 O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Woda, Scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1,0 – 6000) mg/dm3 O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":109,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Biochemical oxygen demand Electrochemical method BOD5 Range PN-EN ISO 5815-1:2019-12","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(1,0 – 6000) mg/dm3 O2"}],"search_zh":"水、污水 生化需氧量 电化学法 BZT5（BOD5） 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"水、污水"},{"_id":"6a5dc9adf1c10c8ce825abff","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu","methodology_en":"Biochemical oxygen demand","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(0,8 – 6,0) mg/dm3 O2"}],"parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(0,8 – 6,0) mg/dm3 O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,8 – 6,0) mg/dm3 O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,8 – 6,0) mg/dm3 O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Woda, Scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,8 – 6,0) mg/dm3 O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":110,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Biochemical oxygen demand Electrochemical method BOD5 Range PN-EN 1899-2:2002","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(0,8 – 6,0) mg/dm3 O2"}],"search_zh":"水、污水 生化需氧量 电化学法 BZT5（BOD5） 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"水、污水"},{"_id":"6a5dc9adf1c10c8ce825ac00","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Zawiesiny ogólne","methodology_en":"Total suspended solids (TSS)","parameters":[{"name":"Zakres","range":"(5,0 – 5000) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(5,0 – 5000) mg/dm3"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawiesiny ogólne\nZakres (5,0 – 5000) mg/dm3\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Zawiesiny ogólne\nZakres (5,0 – 5000) mg/dm3\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, Scieki Zawiesiny ogolne\nZakres (5,0 – 5000) mg/dm3\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":111,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(5,0 – 5000) mg/dm3"}],"search_zh":"水、污水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"水、污水"},{"_id":"6a5dc9adf1c10c8ce825ac01","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie azotu azotynowego","methodology_en":"Nitrite nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,005 – 100) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,005 – 100) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu azotynowego\nZakres (0,005 – 100) mg/dm3\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie azotu azotynowego\nZakres (0,005 – 100) mg/dm3\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, Scieki Stezenie azotu azotynowego\nZakres (0,005 – 100) mg/dm3\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":112,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Nitrite nitrogen concentration Spectrophotometric method Range PN-EN 26777:1999","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,005 – 100) mg/dm3"}],"search_zh":"水、污水 亚硝态氮浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a5dc9adf1c10c8ce825ac02","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie ortofosforanów","methodology_en":"Orthophosphate concentration","parameters":[{"name":"Zakres","range":"(0,050 – 100) mg/dm3 P"}],"parameters_en":[{"name":"Range","range":"(0,050 – 100) mg/dm3 P"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie ortofosforanów\nZakres (0,050 – 100) mg/dm3 P\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010 pkt.4","norm_bases":["PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010 pkt.4"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie ortofosforanów\nZakres (0,050 – 100) mg/dm3 P\nMetoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010 pkt.4 Woda, Scieki Stezenie ortofosforanow\nZakres (0,050 – 100) mg/dm3 P\nMetoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010 pkt.4","categories":["water"],"row_index":113,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Orthophosphate concentration Spectrophotometric method Range PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010 pkt.4","parameters_zh":[{"name":"范围","range":"(0,050 – 100) mg/dm3 P"}],"search_zh":"水、污水 正磷酸盐浓度 分光光度法 范围 PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010 pkt.4","technique_zh":"分光光度法","test_object_zh":"水、污水","methodology_zh":"正磷酸盐浓度"},{"_id":"6a5dc9adf1c10c8ce825ac03","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie fosforu ogólnego","methodology_en":"Total phosphorus concentration","parameters":[{"name":"Zakres","range":"(0,050 – 100) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,050 – 100) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,050 – 100) mg/dm3\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010 pkt. 7","norm_bases":["PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010 pkt. 7"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie fosforu ogólnego\nZakres (0,050 – 100) mg/dm3\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010 pkt. 7 Woda, Scieki Stezenie fosforu ogolnego\nZakres (0,050 – 100) mg/dm3\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010 pkt. 7","categories":["water"],"row_index":114,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Total phosphorus concentration Spectrophotometric method Range PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010 pkt. 7","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,050 – 100) mg/dm3"}],"search_zh":"水、污水 总磷浓度 分光光度法 范围 PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010 pkt. 7","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a5dc9adf1c10c8ce825ac04","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie ogólnego węgla organicznego","methodology_en":"Total organic carbon concentration","parameters":[{"name":"Zakres","range":"(1,0 – 1000) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(1,0 – 1000) mg/dm3"}],"technique":"Metoda spektrometrii w zakresie podczerwieni (IR)","techniques":["Metoda spektrometrii w zakresie podczerwieni (IR)"],"technique_en":"Spectrometry method in the infrared range (IR)","computed":[],"computed_en":[],"activity":"Stężenie ogólnego węgla organicznego\nZakres (1,0 – 1000) mg/dm3\nMetoda spektrometrii w zakresie podczerwieni (IR)","reference":"PN-EN 1484:1999","norm_bases":["PN-EN 1484:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie ogólnego węgla organicznego\nZakres (1,0 – 1000) mg/dm3\nMetoda spektrometrii w zakresie podczerwieni (IR) PN-EN 1484:1999 Woda, Scieki Stezenie ogolnego wegla organicznego\nZakres (1,0 – 1000) mg/dm3\nMetoda spektrometrii w zakresie podczerwieni (IR) PN-EN 1484:1999","categories":["water"],"row_index":115,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Total organic carbon concentration Spectrometry method in the infrared range (IR) Range PN-EN 1484:1999","parameters_zh":[{"name":"范围","range":"(1,0 – 1000) mg/dm3"}],"search_zh":"水、污水 总有机碳浓度 红外光谱法（IR） 范围 PN-EN 1484:1999","test_object_zh":"水、污水","technique_zh":"红外光谱法（IR）","methodology_zh":"总有机碳浓度"},{"_id":"6a5dc9adf1c10c8ce825ac05","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Chemiczne zapotrzebowanie tlenu","methodology_en":"Chemical oxygen demand","parameters":[{"name":"ChZT-Cr"},{"name":"Zakres","range":"(10,0 – 1000) mg/dm3 O2"}],"parameters_en":[{"name":"COD-Cr"},{"name":"Range","range":"(10,0 – 1000) mg/dm3 O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (10,0 – 1000) mg/dm3 O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (10,0 – 1000) mg/dm3 O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda, Scieki Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (10,0 – 1000) mg/dm3 O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":116,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Chemical oxygen demand Spectrophotometric method COD-Cr Range PN-ISO 15705:2005","parameters_zh":[{"name":"化学需氧量（COD-Cr）"},{"name":"范围","range":"(10,0 – 1000) mg/dm3 O2"}],"search_zh":"水、污水 化学需氧量（COD） 分光光度法 化学需氧量（COD-Cr） 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水、污水","methodology_zh":"化学需氧量（COD）"},{"_id":"6a5dc9adf1c10c8ce825ac06","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie pestycydów","methodology_en":"Pesticide concentration","parameters":[{"name":"aldryna","range":"(0,003 – 0,03) μg/dm3"},{"name":"dieldryna","range":"(0,003 – 0,03) μg/dm3"},{"name":"endryna","range":"(0,003 – 0,03) μg/dm3"},{"name":"izodryna","range":"(0,003 – 0,03) μg/dm3"},{"name":"p,p’-DDE","range":"(0,003 – 0,03) μg/dm3"},{"name":"p,p’-DDD","range":"(0,003 – 0,03) μg/dm3"},{"name":"p,p’-DDT","range":"(0,003 – 0,03) μg/dm3"},{"name":"o,p’-DDT","range":"(0,003 – 0,03) μg/dm3"},{"name":"DDT - całkowity"},{"name":"Zakres","range":"(0,003 – 0,03) μg/dm3"},{"name":"1,2,3-trichlorobenzen","range":"(0,004 – 0,04) μg/dm3"},{"name":"1,2,4-trichlorobenzen","range":"(0,004 – 0,04) μg/dm3"},{"name":"1,3,5-trichlorobenzen","range":"(0,004 – 0,04) μg/dm3"},{"name":"TCB - suma","range":"(0,004 – 0,04) μg/dm3"},{"name":"pentachlorobenzen","range":"(0,002 – 0,02) μg/dm3"},{"name":"heksachlorobenzen","range":"(0,002 – 0,02) μg/dm3"},{"name":"α-HCH","range":"(0,003 – 0,03) μg/dm3"},{"name":"β-HCH","range":"(0,003 – 0,03) μg/dm3"},{"name":"γ-HCH","range":"(0,003 – 0,03) μg/dm3"},{"name":"δ-HCH","range":"(0,003 – 0,03) μg/dm3"},{"name":"HCH - suma","range":"(0,003 – 0,03) μg/dm3"},{"name":"α – endosulfan","range":"(0,0015 – 0,015) μg/dm3"},{"name":"β – endosulfan","range":"(0,0015 – 0,015) μg/dm3"},{"name":"endosulfan – suma","range":"(0,0015 – 0,015) μg/dm3"},{"name":"pestycydy - ogółem (DDT całkowity i γ-HCH)","range":"(0,003 – 0,03) μg/dm3"}],"parameters_en":[{"name":"aldrin","range":"(0,003 – 0,03) μg/dm3"},{"name":"dieldrin","range":"(0,003 – 0,03) μg/dm3"},{"name":"endrin","range":"(0,003 – 0,03) μg/dm3"},{"name":"isodrin","range":"(0,003 – 0,03) μg/dm3"},{"name":"p,p’-DDE","range":"(0,003 – 0,03) μg/dm3"},{"name":"p,p’-DDD","range":"(0,003 – 0,03) μg/dm3"},{"name":"p,p’-DDT","range":"(0,003 – 0,03) μg/dm3"},{"name":"o,p’-DDT","range":"(0,003 – 0,03) μg/dm3"},{"name":"DDT - total"},{"name":"Range","range":"(0,003 – 0,03) μg/dm3"},{"name":"1,2,3-trichlorobenzene","range":"(0,004 – 0,04) μg/dm3"},{"name":"1,2,4-trichlorobenzene","range":"(0,004 – 0,04) μg/dm3"},{"name":"1,3,5-trichlorobenzene","range":"(0,004 – 0,04) μg/dm3"},{"name":"TCB - sum","range":"(0,004 – 0,04) μg/dm3"},{"name":"pentachlorobenzene","range":"(0,002 – 0,02) μg/dm3"},{"name":"hexachlorobenzene","range":"(0,002 – 0,02) μg/dm3"},{"name":"α-HCH","range":"(0,003 – 0,03) μg/dm3"},{"name":"β-HCH","range":"(0,003 – 0,03) μg/dm3"},{"name":"γ-HCH","range":"(0,003 – 0,03) μg/dm3"},{"name":"δ-HCH","range":"(0,003 – 0,03) μg/dm3"},{"name":"HCH - sum","range":"(0,003 – 0,03) μg/dm3"},{"name":"α – endosulfan","range":"(0,0015 – 0,015) μg/dm3"},{"name":"β – endosulfan","range":"(0,0015 – 0,015) μg/dm3"},{"name":"endosulfan – sum","range":"(0,0015 – 0,015) μg/dm3"},{"name":"pesticides - total (total DDT and γ-HCH)","range":"(0,003 – 0,03) μg/dm3"}],"technique":"Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","techniques":["Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)"],"technique_en":"Gas chromatography with electron capture detection (GC-ECD)","computed":[],"computed_en":[],"activity":"Stężenie pestycydów\nZakres:\naldryna (0,003 – 0,03) μg/dm3\ndieldryna (0,003 – 0,03) μg/dm3\nendryna (0,003 – 0,03) μg/dm3\nizodryna (0,003 – 0,03) μg/dm3\np,p’-DDE (0,003 – 0,03) μg/dm3\np,p’-DDD (0,003 – 0,03) μg/dm3\np,p’-DDT (0,003 – 0,03) μg/dm3\no,p’-DDT (0,003 – 0,03) μg/dm3\nDDT - całkowity\nZakres (0,003 – 0,03) μg/dm3\n1,2,3-trichlorobenzen (0,004 – 0,04) μg/dm3\n1,2,4-trichlorobenzen (0,004 – 0,04) μg/dm3\n1,3,5-trichlorobenzen (0,004 – 0,04) μg/dm3\nTCB - suma (0,004 – 0,04) μg/dm3\npentachlorobenzen (0,002 – 0,02) μg/dm3\nheksachlorobenzen (0,002 – 0,02) μg/dm3\nα-HCH (0,003 – 0,03) μg/dm3\nβ-HCH (0,003 – 0,03) μg/dm3\nγ-HCH (0,003 – 0,03) μg/dm3\nδ-HCH (0,003 – 0,03) μg/dm3\nHCH - suma (0,003 – 0,03) μg/dm3\nα – endosulfan (0,0015 – 0,015) μg/dm3\nβ – endosulfan (0,0015 – 0,015) μg/dm3\nendosulfan – suma (0,0015 – 0,015) μg/dm3\npestycydy - ogółem (DDT całkowity i γ-HCH) (0,003 – 0,03) μg/dm3\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","reference":"PN-EN ISO 6468:2002","norm_bases":["PN-EN ISO 6468:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie pestycydów\nZakres:\naldryna (0,003 – 0,03) μg/dm3\ndieldryna (0,003 – 0,03) μg/dm3\nendryna (0,003 – 0,03) μg/dm3\nizodryna (0,003 – 0,03) μg/dm3\np,p’-DDE (0,003 – 0,03) μg/dm3\np,p’-DDD (0,003 – 0,03) μg/dm3\np,p’-DDT (0,003 – 0,03) μg/dm3\no,p’-DDT (0,003 – 0,03) μg/dm3\nDDT - całkowity\nZakres (0,003 – 0,03) μg/dm3\n1,2,3-trichlorobenzen (0,004 – 0,04) μg/dm3\n1,2,4-trichlorobenzen (0,004 – 0,04) μg/dm3\n1,3,5-trichlorobenzen (0,004 – 0,04) μg/dm3\nTCB - suma (0,004 – 0,04) μg/dm3\npentachlorobenzen (0,002 – 0,02) μg/dm3\nheksachlorobenzen (0,002 – 0,02) μg/dm3\nα-HCH (0,003 – 0,03) μg/dm3\nβ-HCH (0,003 – 0,03) μg/dm3\nγ-HCH (0,003 – 0,03) μg/dm3\nδ-HCH (0,003 – 0,03) μg/dm3\nHCH - suma (0,003 – 0,03) μg/dm3\nα – endosulfan (0,0015 – 0,015) μg/dm3\nβ – endosulfan (0,0015 – 0,015) μg/dm3\nendosulfan – suma (0,0015 – 0,015) μg/dm3\npestycydy - ogółem (DDT całkowity i γ-HCH) (0,003 – 0,03) μg/dm3\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) PN-EN ISO 6468:2002 Woda, Scieki Stezenie pestycydow\nZakres:\naldryna (0,003 – 0,03) μg/dm3\ndieldryna (0,003 – 0,03) μg/dm3\nendryna (0,003 – 0,03) μg/dm3\nizodryna (0,003 – 0,03) μg/dm3\np,p’-DDE (0,003 – 0,03) μg/dm3\np,p’-DDD (0,003 – 0,03) μg/dm3\np,p’-DDT (0,003 – 0,03) μg/dm3\no,p’-DDT (0,003 – 0,03) μg/dm3\nDDT - calkowity\nZakres (0,003 – 0,03) μg/dm3\n1,2,3-trichlorobenzen (0,004 – 0,04) μg/dm3\n1,2,4-trichlorobenzen (0,004 – 0,04) μg/dm3\n1,3,5-trichlorobenzen (0,004 – 0,04) μg/dm3\nTCB - suma (0,004 – 0,04) μg/dm3\npentachlorobenzen (0,002 – 0,02) μg/dm3\nheksachlorobenzen (0,002 – 0,02) μg/dm3\nα-HCH (0,003 – 0,03) μg/dm3\nβ-HCH (0,003 – 0,03) μg/dm3\nγ-HCH (0,003 – 0,03) μg/dm3\nδ-HCH (0,003 – 0,03) μg/dm3\nHCH - suma (0,003 – 0,03) μg/dm3\nα – endosulfan (0,0015 – 0,015) μg/dm3\nβ – endosulfan (0,0015 – 0,015) μg/dm3\nendosulfan – suma (0,0015 – 0,015) μg/dm3\npestycydy - ogolem (DDT calkowity i γ-HCH) (0,003 – 0,03) μg/dm3\nMetoda chromatografii gazowej z detekcja wychwytu elektronow (GC-ECD) PN-EN ISO 6468:2002","categories":["water"],"row_index":117,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Pesticide concentration Gas chromatography with electron capture detection (GC-ECD) aldrin dieldrin endrin isodrin p,p’-DDE p,p’-DDD p,p’-DDT o,p’-DDT DDT - total Range 1,2,3-trichlorobenzene 1,2,4-trichlorobenzene 1,3,5-trichlorobenzene TCB - sum pentachlorobenzene hexachlorobenzene α-HCH β-HCH γ-HCH δ-HCH HCH - sum α – endosulfan β – endosulfan endosulfan – sum pesticides - total (total DDT and γ-HCH) PN-EN ISO 6468:2002","methodology_zh":"农药浓度","parameters_zh":[{"name":"艾氏剂","range":"(0,003 – 0,03) μg/dm3"},{"name":"狄氏剂","range":"(0,003 – 0,03) μg/dm3"},{"name":"异狄氏剂","range":"(0,003 – 0,03) μg/dm3"},{"name":"异艾氏剂","range":"(0,003 – 0,03) μg/dm3"},{"name":"p,p'-滴滴伊（DDE）","range":"(0,003 – 0,03) μg/dm3"},{"name":"p,p'-滴滴滴（DDD）","range":"(0,003 – 0,03) μg/dm3"},{"name":"p,p'-滴滴涕（DDT）","range":"(0,003 – 0,03) μg/dm3"},{"name":"o,p’-DDT","range":"(0,003 – 0,03) μg/dm3"},{"name":"DDT - całkowity"},{"name":"范围","range":"(0,003 – 0,03) μg/dm3"},{"name":"1,2,3-三氯苯","range":"(0,004 – 0,04) μg/dm3"},{"name":"1,2,4-三氯苯","range":"(0,004 – 0,04) μg/dm3"},{"name":"1,3,5-三氯苯","range":"(0,004 – 0,04) μg/dm3"},{"name":"TCB - suma","range":"(0,004 – 0,04) μg/dm3"},{"name":"五氯苯","range":"(0,002 – 0,02) μg/dm3"},{"name":"六氯苯","range":"(0,002 – 0,02) μg/dm3"},{"name":"α-六六六","range":"(0,003 – 0,03) μg/dm3"},{"name":"β-六六六","range":"(0,003 – 0,03) μg/dm3"},{"name":"γ-六六六（林丹）","range":"(0,003 – 0,03) μg/dm3"},{"name":"δ-六六六","range":"(0,003 – 0,03) μg/dm3"},{"name":"HCH - suma","range":"(0,003 – 0,03) μg/dm3"},{"name":"α – endosulfan","range":"(0,0015 – 0,015) μg/dm3"},{"name":"β – endosulfan","range":"(0,0015 – 0,015) μg/dm3"},{"name":"endosulfan – suma","range":"(0,0015 – 0,015) μg/dm3"},{"name":"pestycydy - ogółem (DDT całkowity i γ-HCH)","range":"(0,003 – 0,03) μg/dm3"}],"search_zh":"水、污水 农药浓度 气相色谱-电子捕获检测法（GC-ECD） 艾氏剂 狄氏剂 异狄氏剂 异艾氏剂 p,p'-滴滴伊（DDE） p,p'-滴滴滴（DDD） p,p'-滴滴涕（DDT） 范围 1,2,3-三氯苯 1,2,4-三氯苯 1,3,5-三氯苯 五氯苯 六氯苯 α-六六六 β-六六六 γ-六六六（林丹） δ-六六六 PN-EN ISO 6468:2002","technique_zh":"气相色谱-电子捕获检测法（GC-ECD）","test_object_zh":"水、污水"},{"_id":"6a5dc9adf1c10c8ce825ac07","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie anionów","methodology_en":"Anion concentrations","parameters":[{"name":"chlorki","range":"(0,10 – 200) mg/dm3"},{"name":"azotyny","range":"(0,010 – 16 ) mg/dm3"},{"name":"azotany","range":"(0,10 – 86) mg/dm3"},{"name":"ortofosforany","range":"(0,061 – 5,0) mg/dm3"},{"name":"siarczany","range":"(0,10 – 200) mg/dm3"},{"name":"fluorki","range":"(0,010 – 0,50) mg/dm3"}],"parameters_en":[{"name":"chlorides","range":"(0,10 – 200) mg/dm3"},{"name":"nitrites","range":"(0,010 – 16 ) mg/dm3"},{"name":"nitrates","range":"(0,10 – 86) mg/dm3"},{"name":"orthophosphates","range":"(0,061 – 5,0) mg/dm3"},{"name":"sulfates","range":"(0,10 – 200) mg/dm3"},{"name":"fluorides","range":"(0,010 – 0,50) mg/dm3"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"technique_en":"Ion chromatography with conductometric detection (IC-CD)","computed":[],"computed_en":[],"activity":"Stężenie anionów\nZakres:\nchlorki (0,10 – 200) mg/dm3\nazotyny (0,010 – 16 ) mg/dm3\nazotany (0,10 – 86) mg/dm3\nortofosforany (0,061 – 5,0) mg/dm3\nsiarczany (0,10 – 200) mg/dm3\nfluorki (0,010 – 0,50) mg/dm3\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie anionów\nZakres:\nchlorki (0,10 – 200) mg/dm3\nazotyny (0,010 – 16 ) mg/dm3\nazotany (0,10 – 86) mg/dm3\nortofosforany (0,061 – 5,0) mg/dm3\nsiarczany (0,10 – 200) mg/dm3\nfluorki (0,010 – 0,50) mg/dm3\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Woda, Scieki Stezenie anionow\nZakres:\nchlorki (0,10 – 200) mg/dm3\nazotyny (0,010 – 16 ) mg/dm3\nazotany (0,10 – 86) mg/dm3\nortofosforany (0,061 – 5,0) mg/dm3\nsiarczany (0,10 – 200) mg/dm3\nfluorki (0,010 – 0,50) mg/dm3\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":118,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Anion concentrations Ion chromatography with conductometric detection (IC-CD) chlorides nitrites nitrates orthophosphates sulfates fluorides PN-EN ISO 10304-1:2009+AC:2012","methodology_zh":"阴离子浓度","search_zh":"水、污水 阴离子浓度 离子色谱-电导检测法（IC-CD） 氯化物 亚硝酸盐 硝酸盐 正磷酸盐 硫酸盐 氟化物 PN-EN ISO 10304-1:2009+AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水、污水","parameters_zh":[{"name":"氯化物","range":"(0,10 – 200) mg/dm3"},{"name":"亚硝酸盐","range":"(0,010 – 16 ) mg/dm3"},{"name":"硝酸盐","range":"(0,10 – 86) mg/dm3"},{"name":"正磷酸盐","range":"(0,061 – 5,0) mg/dm3"},{"name":"硫酸盐","range":"(0,10 – 200) mg/dm3"},{"name":"氟化物","range":"(0,010 – 0,50) mg/dm3"}]},{"_id":"6a5dc9adf1c10c8ce825ac08","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie substancji ekstrahujących się eterem naftowym","methodology_en":"Concentration of substances extractable with petroleum ether","parameters":[{"name":"Zakres","range":"(1,0 – 50) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(1,0 – 50) mg/dm3"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie substancji ekstrahujących się eterem naftowym\nZakres (1,0 – 50) mg/dm3\nMetoda wagowa","reference":"PN-86/C-04573/01","norm_bases":["PN-86/C-04573/01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie substancji ekstrahujących się eterem naftowym\nZakres (1,0 – 50) mg/dm3\nMetoda wagowa PN-86/C-04573/01 Woda, Scieki Stezenie substancji ekstrahujacych sie eterem naftowym\nZakres (1,0 – 50) mg/dm3\nMetoda wagowa PN-86/C-04573/01","categories":["water"],"row_index":119,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Concentration of substances extractable with petroleum ether Gravimetric method Range PN-86/C-04573/01","parameters_zh":[{"name":"范围","range":"(1,0 – 50) mg/dm3"}],"search_zh":"水、污水 石油醚可萃取物浓度 重量法 范围 PN-86/C-04573/01","technique_zh":"重量法","test_object_zh":"水、污水","methodology_zh":"石油醚可萃取物浓度"},{"_id":"6a5dc9adf1c10c8ce825ac09","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie kationów:","methodology_en":"Cation concentrations:","parameters":[{"name":"azot amonowy","range":"(0,050 – 3,0) mg/dm3"},{"name":"wapń","range":"(0,50 – 80) mg/dm3"},{"name":"magnez","range":"(0,50 – 40) mg/dm3"}],"parameters_en":[{"name":"ammonium nitrogen","range":"(0,050 – 3,0) mg/dm3"},{"name":"calcium","range":"(0,50 – 80) mg/dm3"},{"name":"magnesium","range":"(0,50 – 40) mg/dm3"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"technique_en":"Ion chromatography with conductometric detection (IC-CD)","computed":[],"computed_en":[],"activity":"Stężenie kationów:\nZakres:\nazot amonowy (0,050 – 3,0) mg/dm3\nwapń (0,50 – 80) mg/dm3\nmagnez (0,50 – 40) mg/dm3\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 14911:2002","norm_bases":["PN-EN ISO 14911:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie kationów:\nZakres:\nazot amonowy (0,050 – 3,0) mg/dm3\nwapń (0,50 – 80) mg/dm3\nmagnez (0,50 – 40) mg/dm3\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 14911:2002 Woda, Scieki Stezenie kationow:\nZakres:\nazot amonowy (0,050 – 3,0) mg/dm3\nwapn (0,50 – 80) mg/dm3\nmagnez (0,50 – 40) mg/dm3\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 14911:2002","categories":["water"],"row_index":120,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Cation concentrations: Ion chromatography with conductometric detection (IC-CD) ammonium nitrogen calcium magnesium PN-EN ISO 14911:2002","search_zh":"水、污水 阳离子浓度： 离子色谱-电导检测法（IC-CD） 铵态氮 钙 镁 PN-EN ISO 14911:2002","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水、污水","parameters_zh":[{"name":"铵态氮","range":"(0,050 – 3,0) mg/dm3"},{"name":"钙","range":"(0,50 – 80) mg/dm3"},{"name":"镁","range":"(0,50 – 40) mg/dm3"}],"methodology_zh":"阳离子浓度："},{"_id":"6a5dc9adf1c10c8ce825ac0a","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Indeks oleju mineralnego","methodology_en":"Mineral oil index","parameters":[{"name":"Zakres","range":"(0,06 – 600) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,06 – 600) mg/dm3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Indeks oleju mineralnego\nZakres (0,06 – 600) mg/dm3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN ISO 9377-2:2003","norm_bases":["PN-EN ISO 9377-2:2003"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Indeks oleju mineralnego\nZakres (0,06 – 600) mg/dm3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN ISO 9377-2:2003 Woda, Scieki Indeks oleju mineralnego\nZakres (0,06 – 600) mg/dm3\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN ISO 9377-2:2003","categories":["water","petro"],"row_index":121,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Mineral oil index Gas chromatography with flame ionization detection (GC-FID) Range PN-EN ISO 9377-2:2003","parameters_zh":[{"name":"范围","range":"(0,06 – 600) mg/dm3"}],"search_zh":"水、污水 矿物油指数 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-EN ISO 9377-2:2003","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"水、污水","methodology_zh":"矿物油指数"},{"_id":"6a5dc9adf1c10c8ce825ac0b","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Obecność i liczba żywych jaj pasożytów jelitowych Ascaris sp.,Toxocara sp., Trichuris sp.,","methodology_en":"Presence and count of viable eggs of intestinal parasites Ascaris sp.,Toxocara sp., Trichuris sp.,","parameters":[{"name":"Zakres","range":"od 20 jaj/kg"}],"parameters_en":[{"name":"Range","range":"od 20 jaj/kg"}],"technique":"Metoda flotacji, mikroskopowa","techniques":["Metoda flotacji, mikroskopowa"],"technique_en":"Flotation method, microscopic","computed":[],"computed_en":[],"activity":"Obecność i liczba żywych jaj pasożytów jelitowych Ascaris sp.,Toxocara sp., Trichuris sp.,\nZakres od 20 jaj/kg\nMetoda flotacji, mikroskopowa","reference":"PB-09/CLB wydanie 1 z dnia 30.05.2022r.","norm_bases":["PB-09/CLB wydanie 1 z dnia 30.05.2022r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Obecność i liczba żywych jaj pasożytów jelitowych Ascaris sp.,Toxocara sp., Trichuris sp.,\nZakres od 20 jaj/kg\nMetoda flotacji, mikroskopowa PB-09/CLB wydanie 1 z dnia 30.05.2022r. Osady sciekowe Obecnosc i liczba zywych jaj pasozytow jelitowych Ascaris sp.,Toxocara sp., Trichuris sp.,\nZakres od 20 jaj/kg\nMetoda flotacji, mikroskopowa PB-09/CLB wydanie 1 z dnia 30.05.2022r.","categories":["water"],"row_index":122,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge Presence and count of viable eggs of intestinal parasites Ascaris sp.,Toxocara sp., Trichuris sp., Flotation method, microscopic Range PB-09/CLB wydanie 1 z dnia 30.05.2022r.","parameters_zh":[{"name":"范围","range":"od 20 jaj/kg"}],"search_zh":"污泥 肠道寄生虫 Ascaris sp.、Toxocara sp.、Trichuris sp. 活卵的检出与计数 浮选显微镜法 范围 PB-09/CLB wydanie 1 z dnia 30.05.2022r.","test_object_zh":"污泥","technique_zh":"浮选显微镜法","methodology_zh":"肠道寄生虫 Ascaris sp.、Toxocara sp.、Trichuris sp. 活卵的检出与计数"},{"_id":"6a5dc9adf1c10c8ce825ac0c","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Sucha pozostałość / zawartość wody","methodology_en":"Dry residue / water content","parameters":[{"name":"Zakres","range":"(0,1 – 99,9) %"}],"parameters_en":[{"name":"Range","range":"(0,1 – 99,9) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Sucha pozostałość / zawartość wody\nZakres (0,1 – 99,9) %\nMetoda wagowa","reference":"PN-EN 12880:2004","norm_bases":["PN-EN 12880:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Sucha pozostałość / zawartość wody\nZakres (0,1 – 99,9) %\nMetoda wagowa PN-EN 12880:2004 Osady sciekowe Sucha pozostalosc / zawartosc wody\nZakres (0,1 – 99,9) %\nMetoda wagowa PN-EN 12880:2004","categories":["water"],"row_index":123,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge Dry residue / water content Gravimetric method Range PN-EN 12880:2004","parameters_zh":[{"name":"范围","range":"(0,1 – 99,9) %"}],"search_zh":"污泥 干残渣/水分含量 重量法 范围 PN-EN 12880:2004","technique_zh":"重量法","test_object_zh":"污泥","methodology_zh":"干残渣/水分含量"},{"_id":"6a5dc9adf1c10c8ce825ac0d","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Strata przy prażeniu / zawartość substancji organicznych","methodology_en":"Loss on ignition / organic matter content","parameters":[{"name":"Zakres","range":"(0,1 – 80,0) %"}],"parameters_en":[{"name":"Range","range":"(0,1 – 80,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Strata przy prażeniu / zawartość substancji organicznych\nZakres (0,1 – 80,0) %\nMetoda wagowa","reference":"PN-EN 15935:2022-01","norm_bases":["PN-EN 15935:2022-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Strata przy prażeniu / zawartość substancji organicznych\nZakres (0,1 – 80,0) %\nMetoda wagowa PN-EN 15935:2022-01 Osady sciekowe Strata przy prazeniu / zawartosc substancji organicznych\nZakres (0,1 – 80,0) %\nMetoda wagowa PN-EN 15935:2022-01","categories":["water"],"row_index":124,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge Loss on ignition / organic matter content Gravimetric method Range PN-EN 15935:2022-01","parameters_zh":[{"name":"范围","range":"(0,1 – 80,0) %"}],"search_zh":"污泥 重量法 范围 PN-EN 15935:2022-01","technique_zh":"重量法","test_object_zh":"污泥"},{"_id":"6a5dc9adf1c10c8ce825ac0e","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"pH - w H2O","methodology_en":"pH - in H2O","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH - w H2O\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe pH - w H2O\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 Osady sciekowe pH - w H2O\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["water"],"row_index":125,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge pH - in H2O Potentiometric method Range PN-EN ISO 10390:2022-09","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"污泥 pH - 于 H2O 中 电位法 范围 PN-EN ISO 10390:2022-09","technique_zh":"电位法","test_object_zh":"污泥","methodology_zh":"pH - 于 H2O 中"},{"_id":"6a5dc9adf1c10c8ce825ac0f","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Odpady kod: 20 03 03 19 13 03 17 05 03","test_object_en":"Waste code: 20 03 03 19 13 03 17 05 03","methodology":"Zawartość oleju mineralnego (węglowodory C10-C40)","methodology_en":"Mineral oil content (C10-C40 hydrocarbons)","parameters":[{"name":"Zakres","range":"(50 – 10 000) mg/kg"}],"parameters_en":[{"name":"Range","range":"(50 – 10 000) mg/kg"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Zawartość oleju mineralnego (węglowodory C10-C40)\nZakres (50 – 10 000) mg/kg\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 14039:2008","norm_bases":["PN-EN 14039:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady kod: 20 03 03 19 13 03 17 05 03 Zawartość oleju mineralnego (węglowodory C10-C40)\nZakres (50 – 10 000) mg/kg\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 14039:2008 Odpady kod: 20 03 03 19 13 03 17 05 03 Zawartosc oleju mineralnego (weglowodory C10-C40)\nZakres (50 – 10 000) mg/kg\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 14039:2008","categories":["environment","petro"],"row_index":126,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste code: 20 03 03 19 13 03 17 05 03 Mineral oil content (C10-C40 hydrocarbons) Gas chromatography with flame ionization detection (GC-FID) Range PN-EN 14039:2008","parameters_zh":[{"name":"范围","range":"(50 – 10 000) mg/kg"}],"search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-EN 14039:2008","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a5dc9adf1c10c8ce825ac10","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Zawartość oleju mineralnego (węglowodory C12-C35) / suma węglowodorów C12 – C35, składników frakcji oleju","methodology_en":"Mineral oil content (C12-C35 hydrocarbons) / sum of C12 – C35 hydrocarbons, components of the oil fraction","parameters":[{"name":"Zakres","range":"(50 – 10 000) mg/kg"}],"parameters_en":[{"name":"Range","range":"(50 – 10 000) mg/kg"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Zawartość oleju mineralnego (węglowodory C12-C35) / suma węglowodorów C12 – C35, składników frakcji oleju\nZakres (50 – 10 000) mg/kg\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN ISO 16703:2011","norm_bases":["PN-EN ISO 16703:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Zawartość oleju mineralnego (węglowodory C12-C35) / suma węglowodorów C12 – C35, składników frakcji oleju\nZakres (50 – 10 000) mg/kg\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN ISO 16703:2011 Gleba Zawartosc oleju mineralnego (weglowodory C12-C35) / suma weglowodorow C12 – C35, skladnikow frakcji oleju\nZakres (50 – 10 000) mg/kg\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN ISO 16703:2011","categories":["environment","petro"],"row_index":127,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Soil Mineral oil content (C12-C35 hydrocarbons) / sum of C12 – C35 hydrocarbons, components of the oil fraction Gas chromatography with flame ionization detection (GC-FID) Range PN-EN ISO 16703:2011","parameters_zh":[{"name":"范围","range":"(50 – 10 000) mg/kg"}],"search_zh":"土壤 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-EN ISO 16703:2011","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"土壤"},{"_id":"6a5dc9adf1c10c8ce825ac11","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Zawartość suchej masy / zawartość wody","methodology_en":"Dry matter content / water content","parameters":[{"name":"Zakres","range":"(0,1 – 99,9)%"}],"parameters_en":[{"name":"Range","range":"(0,1 – 99,9)%"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość suchej masy / zawartość wody\nZakres (0,1 – 99,9)%\nMetoda wagowa","reference":"PN-ISO 11465:1999","norm_bases":["PN-ISO 11465:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Zawartość suchej masy / zawartość wody\nZakres (0,1 – 99,9)%\nMetoda wagowa PN-ISO 11465:1999 Gleba Zawartosc suchej masy / zawartosc wody\nZakres (0,1 – 99,9)%\nMetoda wagowa PN-ISO 11465:1999","categories":["water","environment"],"row_index":128,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Soil Dry matter content / water content Gravimetric method Range PN-ISO 11465:1999","parameters_zh":[{"name":"范围","range":"(0,1 – 99,9)%"}],"search_zh":"土壤 干物质含量/水分含量 重量法 范围 PN-ISO 11465:1999","technique_zh":"重量法","test_object_zh":"土壤","methodology_zh":"干物质含量/水分含量"},{"_id":"6a5dc9adf1c10c8ce825ac12","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Zawartość pestycydów aldryna (0,2 – 120) μg/kg dieldryna (0,2 – 400) μg/kg endryna (0,2 – 400) μg/kg p,p’-DDE (0,2 – 120) μg/kg p,p’-DDD (0,2 – 120) μg/kg p,p’-DDT (0,2 – 250) μg/kg o,p’-DDT (0,2 – 250) μg/kg, DDT-całkowity (0,2 – 250) μg/kg α-HCH (0,2 – 400) μg/kg β-HCH (0,2 – 300) μg/kg γ-HCH (0,2 – 300) μg/kg","methodology_en":"Pesticides content aldrin (0,2 – 120) μg/kg dieldrin (0,2 – 400) μg/kg endrin (0,2 – 400) μg/kg p,p’-DDE (0,2 – 120) μg/kg p,p’-DDD (0,2 – 120) μg/kg p,p’-DDT (0,2 – 250) μg/kg o,p’-DDT (0,2 – 250) μg/kg, total DDT (0,2 – 250) μg/kg α-HCH (0,2 – 400) μg/kg β-HCH (0,2 – 300) μg/kg γ-HCH (0,2 – 300) μg/kg","parameters":[],"parameters_en":[],"technique":"Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","techniques":["Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)"],"technique_en":"Gas chromatography with electron capture detection (GC-ECD)","computed":[],"computed_en":[],"activity":"Zawartość pestycydów aldryna (0,2 – 120) μg/kg dieldryna (0,2 – 400) μg/kg endryna (0,2 – 400) μg/kg p,p’-DDE (0,2 – 120) μg/kg p,p’-DDD (0,2 – 120) μg/kg p,p’-DDT (0,2 – 250) μg/kg o,p’-DDT (0,2 – 250) μg/kg, DDT-całkowity (0,2 – 250) μg/kg α-HCH (0,2 – 400) μg/kg β-HCH (0,2 – 300) μg/kg γ-HCH (0,2 – 300) μg/kg\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","reference":"PN-ISO 10382:2007","norm_bases":["PN-ISO 10382:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Zawartość pestycydów aldryna (0,2 – 120) μg/kg dieldryna (0,2 – 400) μg/kg endryna (0,2 – 400) μg/kg p,p’-DDE (0,2 – 120) μg/kg p,p’-DDD (0,2 – 120) μg/kg p,p’-DDT (0,2 – 250) μg/kg o,p’-DDT (0,2 – 250) μg/kg, DDT-całkowity (0,2 – 250) μg/kg α-HCH (0,2 – 400) μg/kg β-HCH (0,2 – 300) μg/kg γ-HCH (0,2 – 300) μg/kg\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) PN-ISO 10382:2007 Gleba Zawartosc pestycydow aldryna (0,2 – 120) μg/kg dieldryna (0,2 – 400) μg/kg endryna (0,2 – 400) μg/kg p,p’-DDE (0,2 – 120) μg/kg p,p’-DDD (0,2 – 120) μg/kg p,p’-DDT (0,2 – 250) μg/kg o,p’-DDT (0,2 – 250) μg/kg, DDT-calkowity (0,2 – 250) μg/kg α-HCH (0,2 – 400) μg/kg β-HCH (0,2 – 300) μg/kg γ-HCH (0,2 – 300) μg/kg\nMetoda chromatografii gazowej z detekcja wychwytu elektronow (GC-ECD) PN-ISO 10382:2007","categories":["environment"],"row_index":129,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Soil Pesticides content aldrin (0,2 – 120) μg/kg dieldrin (0,2 – 400) μg/kg endrin (0,2 – 400) μg/kg p,p’-DDE (0,2 – 120) μg/kg p,p’-DDD (0,2 – 120) μg/kg p,p’-DDT (0,2 – 250) μg/kg o,p’-DDT (0,2 – 250) μg/kg, total DDT (0,2 – 250) μg/kg α-HCH (0,2 – 400) μg/kg β-HCH (0,2 – 300) μg/kg γ-HCH (0,2 – 300) μg/kg Gas chromatography with electron capture detection (GC-ECD) PN-ISO 10382:2007","search_zh":"土壤 气相色谱-电子捕获检测法（GC-ECD） PN-ISO 10382:2007","technique_zh":"气相色谱-电子捕获检测法（GC-ECD）","test_object_zh":"土壤"},{"_id":"6a5dc9adf1c10c8ce825ac13","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 Gleba pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["environment"],"row_index":130,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Soil pH Potentiometric method Range PN-EN ISO 10390:2022-09","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"土壤 pH 值 电位法 范围 PN-EN ISO 10390:2022-09","technique_zh":"电位法","test_object_zh":"土壤"},{"_id":"6a5dc9adf1c10c8ce825ac14","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Sumaryczna zawartość wapnia i magnezu ( twardość ogólna)","methodology_en":"Total calcium and magnesium content ( total hardness)","parameters":[{"name":"Zakres","range":"(5,0 – 1000) mg/dm3 CaCO3"}],"parameters_en":[{"name":"Range","range":"(5,0 – 1000) mg/dm3 CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Sumaryczna zawartość wapnia i magnezu ( twardość ogólna)\nZakres (5,0 – 1000) mg/dm3 CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Sumaryczna zawartość wapnia i magnezu ( twardość ogólna)\nZakres (5,0 – 1000) mg/dm3 CaCO3\nMetoda miareczkowa PN-ISO 6059:1999 Woda Sumaryczna zawartosc wapnia i magnezu ( twardosc ogolna)\nZakres (5,0 – 1000) mg/dm3 CaCO3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":131,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Total calcium and magnesium content ( total hardness) Titrimetric method Range PN-ISO 6059:1999","parameters_zh":[{"name":"范围","range":"(5,0 – 1000) mg/dm3 CaCO3"}],"search_zh":"水 滴定法 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"水"},{"_id":"6a5dc9adf1c10c8ce825ac15","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie ogólnego węgla organicznego","methodology_en":"Total organic carbon concentration","parameters":[{"name":"Zakres","range":"(0,50 – 1000) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,50 – 1000) mg/dm3"}],"technique":"Metoda spektrometrii w zakresie podczerwieni (IR)","techniques":["Metoda spektrometrii w zakresie podczerwieni (IR)"],"technique_en":"Spectrometry method in the infrared range (IR)","computed":[],"computed_en":[],"activity":"Stężenie ogólnego węgla organicznego\nZakres (0,50 – 1000) mg/dm3\nMetoda spektrometrii w zakresie podczerwieni (IR)","reference":"PN-EN 1484:1999","norm_bases":["PN-EN 1484:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie ogólnego węgla organicznego\nZakres (0,50 – 1000) mg/dm3\nMetoda spektrometrii w zakresie podczerwieni (IR) PN-EN 1484:1999 Woda Stezenie ogolnego wegla organicznego\nZakres (0,50 – 1000) mg/dm3\nMetoda spektrometrii w zakresie podczerwieni (IR) PN-EN 1484:1999","categories":["water"],"row_index":132,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Total organic carbon concentration Spectrometry method in the infrared range (IR) Range PN-EN 1484:1999","parameters_zh":[{"name":"范围","range":"(0,50 – 1000) mg/dm3"}],"search_zh":"水 总有机碳浓度 红外光谱法（IR） 范围 PN-EN 1484:1999","test_object_zh":"水","technique_zh":"红外光谱法（IR）","methodology_zh":"总有机碳浓度"},{"_id":"6a5dc9adf1c10c8ce825ac16","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie chlorofilu a","methodology_en":"Chlorophyll a concentration","parameters":[{"name":"Zakres","range":"(1,1 – 350) μg/dm3"}],"parameters_en":[{"name":"Range","range":"(1,1 – 350) μg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie chlorofilu a\nZakres (1,1 – 350) μg/dm3\nMetoda spektrofotometryczna","reference":"PN-ISO 10260:2002","norm_bases":["PN-ISO 10260:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie chlorofilu a\nZakres (1,1 – 350) μg/dm3\nMetoda spektrofotometryczna PN-ISO 10260:2002 Woda Stezenie chlorofilu a\nZakres (1,1 – 350) μg/dm3\nMetoda spektrofotometryczna PN-ISO 10260:2002","categories":["water"],"row_index":133,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Chlorophyll a concentration Spectrophotometric method Range PN-ISO 10260:2002","parameters_zh":[{"name":"范围","range":"(1,1 – 350) μg/dm3"}],"search_zh":"水 分光光度法 范围 PN-ISO 10260:2002","technique_zh":"分光光度法","test_object_zh":"水"},{"_id":"6a5dc9adf1c10c8ce825ac17","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie azotu amonowego","methodology_en":"Ammonium nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,05 – 200) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,05 – 200) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego\nZakres (0,05 – 200) mg/dm3\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie azotu amonowego\nZakres (0,05 – 200) mg/dm3\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, Scieki Stezenie azotu amonowego\nZakres (0,05 – 200) mg/dm3\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":134,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Ammonium nitrogen concentration Spectrophotometric method Range PN-ISO 7150-1:2002","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,05 – 200) mg/dm3"}],"search_zh":"水、污水 氨氮浓度 分光光度法 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a5dc9adf1c10c8ce825ac18","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie azotu azotanowego","methodology_en":"Nitrate nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,10 – 200) mg/dm3"},{"name":"Stężenie azotanów","range":"(0,44 – 886) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,10 – 200) mg/dm3"},{"name":"Nitrate concentration","range":"(0,44 – 886) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu azotanowego\nZakres:\nZakres (0,10 – 200) mg/dm3\nStężenie azotanów (0,44 – 886) mg/dm3\nMetoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie azotu azotanowego\nZakres:\nZakres (0,10 – 200) mg/dm3\nStężenie azotanów (0,44 – 886) mg/dm3\nMetoda spektrofotometryczna PN-82/C-04576/08 Woda, Scieki Stezenie azotu azotanowego\nZakres:\nZakres (0,10 – 200) mg/dm3\nStezenie azotanow (0,44 – 886) mg/dm3\nMetoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":135,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Nitrate nitrogen concentration Spectrophotometric method Range Nitrate concentration PN-82/C-04576/08","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,10 – 200) mg/dm3"},{"name":"硝酸盐浓度","range":"(0,44 – 886) mg/dm3"}],"search_zh":"水、污水 硝态氮浓度 分光光度法 范围 硝酸盐浓度 PN-82/C-04576/08","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a5dc9adf1c10c8ce825ac19","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie azotu azotynowego","methodology_en":"Nitrite nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,0024 – 10) mg/dm3"},{"name":"Stężenie azotynów","range":"(0,060 – 250) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,0024 – 10) mg/dm3"},{"name":"Nitrite concentration","range":"(0,060 – 250) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu azotynowego\nZakres:\nZakres (0,0024 – 10) mg/dm3\nStężenie azotynów (0,060 – 250) mg/dm3\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie azotu azotynowego\nZakres:\nZakres (0,0024 – 10) mg/dm3\nStężenie azotynów (0,060 – 250) mg/dm3\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, Scieki Stezenie azotu azotynowego\nZakres:\nZakres (0,0024 – 10) mg/dm3\nStezenie azotynow (0,060 – 250) mg/dm3\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":136,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Nitrite nitrogen concentration Spectrophotometric method Range Nitrite concentration PN-EN 26777:1999","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,0024 – 10) mg/dm3"},{"name":"亚硝酸盐浓度","range":"(0,060 – 250) mg/dm3"}],"search_zh":"水、污水 亚硝态氮浓度 分光光度法 范围 亚硝酸盐浓度 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a5dc9adf1c10c8ce825ac1a","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie azotu Kjeldahla","methodology_en":"Kjeldahl nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,20 – 1000) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,20 – 1000) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu Kjeldahla\nZakres (0,20 – 1000) mg/dm3\nMetoda spektrofotometryczna","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie azotu Kjeldahla\nZakres (0,20 – 1000) mg/dm3\nMetoda spektrofotometryczna PN-EN 25663:2001 Woda, Scieki Stezenie azotu Kjeldahla\nZakres (0,20 – 1000) mg/dm3\nMetoda spektrofotometryczna PN-EN 25663:2001","categories":["water"],"row_index":137,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Kjeldahl nitrogen concentration Spectrophotometric method Range PN-EN 25663:2001","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(0,20 – 1000) mg/dm3"}],"search_zh":"水、污水 凯氏氮浓度 分光光度法 范围 PN-EN 25663:2001","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a5dc9adf1c10c8ce825ac1b","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie azotu ogólnego (z obliczeń)","methodology_en":"Total nitrogen concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PB-049/WA wydanie 3 z dnia 15.07.2019 r.","norm_bases":["PB-049/WA wydanie 3 z dnia 15.07.2019 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie azotu ogólnego (z obliczeń) PB-049/WA wydanie 3 z dnia 15.07.2019 r. Woda, Scieki Stezenie azotu ogolnego (z obliczen) PB-049/WA wydanie 3 z dnia 15.07.2019 r.","categories":["water"],"row_index":138,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Total nitrogen concentration (calculated) PB-049/WA wydanie 3 z dnia 15.07.2019 r.","methodology_zh":"总氮浓度（计算值）","search_zh":"水、污水 总氮浓度（计算值） PB-049/WA wydanie 3 z dnia 15.07.2019 r.","test_object_zh":"水、污水"},{"_id":"6a5dc9adf1c10c8ce825ac1c","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie chlorków","methodology_en":"Chloride concentration","parameters":[{"name":"Zakres","range":"(5,0 – 2000) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(5,0 – 2000) mg/dm3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie chlorków\nZakres (5,0 – 2000) mg/dm3\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie chlorków\nZakres (5,0 – 2000) mg/dm3\nMetoda miareczkowa PN-ISO 9297:1994 Woda, Scieki Stezenie chlorkow\nZakres (5,0 – 2000) mg/dm3\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":139,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Chloride concentration Titrimetric method Range PN-ISO 9297:1994","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,0 – 2000) mg/dm3"}],"search_zh":"水、污水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水、污水"},{"_id":"6a5dc9adf1c10c8ce825ac1d","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Indeks nadmanganianowy","methodology_en":"Permanganate index","parameters":[{"name":"Zakres","range":"(0,85 – 200) mg/dm3 O2"}],"parameters_en":[{"name":"Range","range":"(0,85 – 200) mg/dm3 O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Indeks nadmanganianowy\nZakres (0,85 – 200) mg/dm3 O2\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Indeks nadmanganianowy\nZakres (0,85 – 200) mg/dm3 O2\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda, Scieki Indeks nadmanganianowy\nZakres (0,85 – 200) mg/dm3 O2\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":140,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Permanganate index Titrimetric method Range PN-EN ISO 8467:2001","methodology_zh":"高锰酸盐指数","parameters_zh":[{"name":"范围","range":"(0,85 – 200) mg/dm3 O2"}],"search_zh":"水、污水 高锰酸盐指数 滴定法 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"水、污水"},{"_id":"6a5dc9adf1c10c8ce825ac1e","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie fosforanów rozpuszczonych","methodology_en":"Dissolved phosphate concentration","parameters":[{"name":"Zakres","range":"(0,025 – 240) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,025 – 240) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie fosforanów rozpuszczonych\nZakres (0,025 – 240) mg/dm3\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006+Ap1:2010+ Ap2:2010 p. 4","norm_bases":["PN-EN ISO 6878:2006+Ap1:2010+ Ap2:2010 p. 4"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie fosforanów rozpuszczonych\nZakres (0,025 – 240) mg/dm3\nMetoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010+ Ap2:2010 p. 4 Woda, Scieki Stezenie fosforanow rozpuszczonych\nZakres (0,025 – 240) mg/dm3\nMetoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010+ Ap2:2010 p. 4","categories":["water"],"row_index":141,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Dissolved phosphate concentration Spectrophotometric method Range PN-EN ISO 6878:2006+Ap1:2010+ Ap2:2010 p. 4","parameters_zh":[{"name":"范围","range":"(0,025 – 240) mg/dm3"}],"search_zh":"水、污水 溶解性磷酸盐浓度 分光光度法 范围 PN-EN ISO 6878:2006+Ap1:2010+ Ap2:2010 p. 4","technique_zh":"分光光度法","test_object_zh":"水、污水","methodology_zh":"溶解性磷酸盐浓度"},{"_id":"6a5dc9adf1c10c8ce825ac1f","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie fosforu ogólnego","methodology_en":"Total phosphorus concentration","parameters":[{"name":"Zakres","range":"(0,010 – 80) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,010 – 80) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,010 – 80) mg/dm3\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006+Ap1:2010+ Ap2:2010 p. 4, p. 7, p. 8","norm_bases":["PN-EN ISO 6878:2006+Ap1:2010+ Ap2:2010 p. 4, p. 7, p. 8"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie fosforu ogólnego\nZakres (0,010 – 80) mg/dm3\nMetoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010+ Ap2:2010 p. 4, p. 7, p. 8 Woda, Scieki Stezenie fosforu ogolnego\nZakres (0,010 – 80) mg/dm3\nMetoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010+ Ap2:2010 p. 4, p. 7, p. 8","categories":["water"],"row_index":142,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Total phosphorus concentration Spectrophotometric method Range PN-EN ISO 6878:2006+Ap1:2010+ Ap2:2010 p. 4, p. 7, p. 8","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,010 – 80) mg/dm3"}],"search_zh":"水、污水 总磷浓度 分光光度法 范围 PN-EN ISO 6878:2006+Ap1:2010+ Ap2:2010 p. 4, p. 7, p. 8","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a5dc9adf1c10c8ce825ac20","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Całkowite substancje rozpuszczone (TDS)","methodology_en":"Total dissolved solids (TDS)","parameters":[{"name":"Zakres","range":"(50,0 – 10000) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(50,0 – 10000) mg/dm3"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Całkowite substancje rozpuszczone (TDS)\nZakres (50,0 – 10000) mg/dm3\nMetoda wagowa","reference":"PN-EN 15216:2022-03","norm_bases":["PN-EN 15216:2022-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Całkowite substancje rozpuszczone (TDS)\nZakres (50,0 – 10000) mg/dm3\nMetoda wagowa PN-EN 15216:2022-03 Woda, Scieki Calkowite substancje rozpuszczone (TDS)\nZakres (50,0 – 10000) mg/dm3\nMetoda wagowa PN-EN 15216:2022-03","categories":["water"],"row_index":143,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Total dissolved solids (TDS) Gravimetric method Range PN-EN 15216:2022-03","parameters_zh":[{"name":"范围","range":"(50,0 – 10000) mg/dm3"}],"search_zh":"水、污水 溶解性总固体（TDS） 重量法 范围 PN-EN 15216:2022-03","technique_zh":"重量法","test_object_zh":"水、污水","methodology_zh":"溶解性总固体（TDS）"},{"_id":"6a5dc9adf1c10c8ce825ac21","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Zawiesiny ogólne","methodology_en":"Total suspended solids (TSS)","parameters":[{"name":"Zakres","range":"(5,0 – 1000) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(5,0 – 1000) mg/dm3"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawiesiny ogólne\nZakres (5,0 – 1000) mg/dm3\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Zawiesiny ogólne\nZakres (5,0 – 1000) mg/dm3\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, Scieki Zawiesiny ogolne\nZakres (5,0 – 1000) mg/dm3\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":144,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(5,0 – 1000) mg/dm3"}],"search_zh":"水、污水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"水、污水"},{"_id":"6a5dc9adf1c10c8ce825ac22","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie siarczanów","methodology_en":"Sulfate concentration","parameters":[{"name":"Zakres","range":"(5,0 – 2000) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(5,0 – 2000) mg/dm3"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie siarczanów\nZakres (5,0 – 2000) mg/dm3\nMetoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie siarczanów\nZakres (5,0 – 2000) mg/dm3\nMetoda wagowa PN-ISO 9280:2002 Woda, Scieki Stezenie siarczanow\nZakres (5,0 – 2000) mg/dm3\nMetoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":145,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Sulfate concentration Gravimetric method Range PN-ISO 9280:2002","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(5,0 – 2000) mg/dm3"}],"search_zh":"水、污水 硫酸盐浓度 重量法 范围 PN-ISO 9280:2002","technique_zh":"重量法","test_object_zh":"水、污水"},{"_id":"6a5dc9adf1c10c8ce825ac23","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie chromu sześciowartościowego","methodology_en":"Hexavalent chromium concentration","parameters":[{"name":"Zakres","range":"(0,0080 – 100) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,0080 – 100) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie chromu sześciowartościowego\nZakres (0,0080 – 100) mg/dm3\nMetoda spektrofotometryczna","reference":"PN-77/C-04604.08","norm_bases":["PN-77/C-04604.08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie chromu sześciowartościowego\nZakres (0,0080 – 100) mg/dm3\nMetoda spektrofotometryczna PN-77/C-04604.08 Woda, Scieki Stezenie chromu szesciowartosciowego\nZakres (0,0080 – 100) mg/dm3\nMetoda spektrofotometryczna PN-77/C-04604.08","categories":["water"],"row_index":146,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Hexavalent chromium concentration Spectrophotometric method Range PN-77/C-04604.08","parameters_zh":[{"name":"范围","range":"(0,0080 – 100) mg/dm3"}],"search_zh":"水、污水 六价铬浓度 分光光度法 范围 PN-77/C-04604.08","technique_zh":"分光光度法","test_object_zh":"水、污水","methodology_zh":"六价铬浓度"},{"_id":"6a5dc9adf1c10c8ce825ac24","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu","methodology_en":"Biochemical oxygen demand","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(1,0 – 6,0) mg/dm3 O2"}],"parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(1,0 – 6,0) mg/dm3 O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1,0 – 6,0) mg/dm3 O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1,0 – 6,0) mg/dm3 O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Woda, Scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1,0 – 6,0) mg/dm3 O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":147,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Biochemical oxygen demand Electrochemical method BOD5 Range PN-EN 1899-2:2002","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(1,0 – 6,0) mg/dm3 O2"}],"search_zh":"水、污水 生化需氧量 电化学法 BZT5（BOD5） 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"水、污水"},{"_id":"6a5dc9adf1c10c8ce825ac25","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu","methodology_en":"Biochemical oxygen demand","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(1,0 – 6000) mg/dm3 O2"}],"parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(1,0 – 6000) mg/dm3 O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1,0 – 6000) mg/dm3 O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1,0 – 6000) mg/dm3 O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Woda, Scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1,0 – 6000) mg/dm3 O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":148,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Biochemical oxygen demand Electrochemical method BOD5 Range PN-EN ISO 5815-1:2019-12","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(1,0 – 6000) mg/dm3 O2"}],"search_zh":"水、污水 生化需氧量 电化学法 BZT5（BOD5） 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"水、污水"},{"_id":"6a5dc9adf1c10c8ce825ac26","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie surfaktantów anionowych","methodology_en":"Anionic surfactant concentration","parameters":[{"name":"Zakres","range":"(0,10 – 50) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,10 – 50) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie surfaktantów anionowych\nZakres (0,10 – 50) mg/dm3\nMetoda spektrofotometryczna","reference":"PN-EN 903:2002","norm_bases":["PN-EN 903:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie surfaktantów anionowych\nZakres (0,10 – 50) mg/dm3\nMetoda spektrofotometryczna PN-EN 903:2002 Woda, Scieki Stezenie surfaktantow anionowych\nZakres (0,10 – 50) mg/dm3\nMetoda spektrofotometryczna PN-EN 903:2002","categories":["water"],"row_index":149,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Anionic surfactant concentration Spectrophotometric method Range PN-EN 903:2002","parameters_zh":[{"name":"范围","range":"(0,10 – 50) mg/dm3"}],"search_zh":"水、污水 阴离子表面活性剂浓度 分光光度法 范围 PN-EN 903:2002","technique_zh":"分光光度法","test_object_zh":"水、污水","methodology_zh":"阴离子表面活性剂浓度"},{"_id":"6a5dc9adf1c10c8ce825ac27","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie substancji ekstrahujących się eterem naftowym","methodology_en":"Concentration of substances extractable with petroleum ether","parameters":[{"name":"Zakres","range":"(1,0 – 200) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(1,0 – 200) mg/dm3"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie substancji ekstrahujących się eterem naftowym\nZakres (1,0 – 200) mg/dm3\nMetoda wagowa","reference":"PN-86/C-04573.01","norm_bases":["PN-86/C-04573.01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie substancji ekstrahujących się eterem naftowym\nZakres (1,0 – 200) mg/dm3\nMetoda wagowa PN-86/C-04573.01 Woda, Scieki Stezenie substancji ekstrahujacych sie eterem naftowym\nZakres (1,0 – 200) mg/dm3\nMetoda wagowa PN-86/C-04573.01","categories":["water"],"row_index":150,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Concentration of substances extractable with petroleum ether Gravimetric method Range PN-86/C-04573.01","parameters_zh":[{"name":"范围","range":"(1,0 – 200) mg/dm3"}],"search_zh":"水、污水 石油醚可萃取物浓度 重量法 范围 PN-86/C-04573.01","technique_zh":"重量法","test_object_zh":"水、污水","methodology_zh":"石油醚可萃取物浓度"},{"_id":"6a5dc9adf1c10c8ce825ac28","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie anionów:","methodology_en":"Anion concentrations:","parameters":[{"name":"chlorki","range":"(0,50 – 70,0) mg/dm3"},{"name":"azotyny","range":"(0,50 – 50,0) mg/dm3"},{"name":"azotany","range":"(0,50 – 70,0) mg/dm3"},{"name":"ortofosforany","range":"(0,50 – 70,0) mg/dm3"},{"name":"siarczany","range":"(0,50 – 70,0) mg/dm3"},{"name":"fluorki","range":"(0,10 – 14) mg/dm3"}],"parameters_en":[{"name":"chlorides","range":"(0,50 – 70,0) mg/dm3"},{"name":"nitrites","range":"(0,50 – 50,0) mg/dm3"},{"name":"nitrates","range":"(0,50 – 70,0) mg/dm3"},{"name":"orthophosphates","range":"(0,50 – 70,0) mg/dm3"},{"name":"sulfates","range":"(0,50 – 70,0) mg/dm3"},{"name":"fluorides","range":"(0,10 – 14) mg/dm3"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"technique_en":"Ion chromatography with conductometric detection (IC-CD)","computed":[],"computed_en":[],"activity":"Stężenie anionów:\nZakres:\nchlorki (0,50 – 70,0) mg/dm3\nazotyny (0,50 – 50,0) mg/dm3\nazotany (0,50 – 70,0) mg/dm3\nortofosforany (0,50 – 70,0) mg/dm3\nsiarczany (0,50 – 70,0) mg/dm3\nfluorki (0,10 – 14) mg/dm3\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie anionów:\nZakres:\nchlorki (0,50 – 70,0) mg/dm3\nazotyny (0,50 – 50,0) mg/dm3\nazotany (0,50 – 70,0) mg/dm3\nortofosforany (0,50 – 70,0) mg/dm3\nsiarczany (0,50 – 70,0) mg/dm3\nfluorki (0,10 – 14) mg/dm3\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Woda, Scieki Stezenie anionow:\nZakres:\nchlorki (0,50 – 70,0) mg/dm3\nazotyny (0,50 – 50,0) mg/dm3\nazotany (0,50 – 70,0) mg/dm3\nortofosforany (0,50 – 70,0) mg/dm3\nsiarczany (0,50 – 70,0) mg/dm3\nfluorki (0,10 – 14) mg/dm3\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":151,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Anion concentrations: Ion chromatography with conductometric detection (IC-CD) chlorides nitrites nitrates orthophosphates sulfates fluorides PN-EN ISO 10304-1:2009+AC:2012","methodology_zh":"阴离子浓度：","search_zh":"水、污水 阴离子浓度： 离子色谱-电导检测法（IC-CD） 氯化物 亚硝酸盐 硝酸盐 正磷酸盐 硫酸盐 氟化物 PN-EN ISO 10304-1:2009+AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水、污水","parameters_zh":[{"name":"氯化物","range":"(0,50 – 70,0) mg/dm3"},{"name":"亚硝酸盐","range":"(0,50 – 50,0) mg/dm3"},{"name":"硝酸盐","range":"(0,50 – 70,0) mg/dm3"},{"name":"正磷酸盐","range":"(0,50 – 70,0) mg/dm3"},{"name":"硫酸盐","range":"(0,50 – 70,0) mg/dm3"},{"name":"氟化物","range":"(0,10 – 14) mg/dm3"}]},{"_id":"6a5dc9adf1c10c8ce825ac29","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie azotu amonowego","methodology_en":"Ammonium nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,080 – 4,0) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,080 – 4,0) mg/dm3"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"technique_en":"Ion chromatography with conductometric detection (IC-CD)","computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego\nZakres (0,080 – 4,0) mg/dm3\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 14911:2002","norm_bases":["PN-EN ISO 14911:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie azotu amonowego\nZakres (0,080 – 4,0) mg/dm3\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 14911:2002 Woda, Scieki Stezenie azotu amonowego\nZakres (0,080 – 4,0) mg/dm3\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 14911:2002","categories":["water"],"row_index":152,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Ammonium nitrogen concentration Ion chromatography with conductometric detection (IC-CD) Range PN-EN ISO 14911:2002","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,080 – 4,0) mg/dm3"}],"search_zh":"水、污水 氨氮浓度 离子色谱-电导检测法（IC-CD） 范围 PN-EN ISO 14911:2002","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水、污水"},{"_id":"6a5dc9adf1c10c8ce825ac2a","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Chemiczne zapotrzebowanie tlenu","methodology_en":"Chemical oxygen demand","parameters":[{"name":"ChZT-Cr"},{"name":"Zakres","range":"(10,0 – 5000) mg/dm3 O2"}],"parameters_en":[{"name":"COD-Cr"},{"name":"Range","range":"(10,0 – 5000) mg/dm3 O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (10,0 – 5000) mg/dm3 O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (10,0 – 5000) mg/dm3 O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda, Scieki Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (10,0 – 5000) mg/dm3 O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":153,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Chemical oxygen demand Spectrophotometric method COD-Cr Range PN-ISO 15705:2005","parameters_zh":[{"name":"化学需氧量（COD-Cr）"},{"name":"范围","range":"(10,0 – 5000) mg/dm3 O2"}],"search_zh":"水、污水 化学需氧量（COD） 分光光度法 化学需氧量（COD-Cr） 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水、污水","methodology_zh":"化学需氧量（COD）"},{"_id":"6a5dc9adf1c10c8ce825ac2b","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie wielopierścieniowych węglowodorów aromatycznych","methodology_en":"Concentration of polycyclic aromatic hydrocarbons","parameters":[{"name":"naftalen","range":"(0,0020 – 100) μg/dm3"},{"name":"antracen","range":"(0,0010 – 100) μg/dm3"},{"name":"fluoranten","range":"(0,0020 – 100) μg/dm3"},{"name":"benzo(b)fluoranten"},{"name":"Zakres","range":"(0,0010 – 100) μg/dm3"},{"name":"benzo(k)fluoranten","range":"(0,0005 – 50) μg/dm3"},{"name":"benzo(a)piren","range":"(0,0010 – 100) μg/dm3"},{"name":"dibenzo(ah)antracen","range":"(0,001 – 100) μg/dm3"},{"name":"benzo(ghi)perylen","range":"(0,0014 – 100) μg/dm3"},{"name":"indeno","range":"(1,2,3-cd)piren"},{"name":"(0,001 – 100) μg/dm3"}],"parameters_en":[{"name":"naphthalene","range":"(0,0020 – 100) μg/dm3"},{"name":"anthracene","range":"(0,0010 – 100) μg/dm3"},{"name":"fluoranthene","range":"(0,0020 – 100) μg/dm3"},{"name":"benzo(b)fluoranthene"},{"name":"Range","range":"(0,0010 – 100) μg/dm3"},{"name":"benzo(k)fluoranthene","range":"(0,0005 – 50) μg/dm3"},{"name":"benzo(a)pyrene","range":"(0,0010 – 100) μg/dm3"},{"name":"dibenzo(ah)anthracene","range":"(0,001 – 100) μg/dm3"},{"name":"benzo(ghi)perylene","range":"(0,0014 – 100) μg/dm3"},{"name":"indeno","range":"(1,2,3-cd)piren"},{"name":"(0,001 – 100) μg/dm3"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluoroscencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluoroscencyjną (HPLC-FLD)"],"technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD)","computed":[],"computed_en":[],"activity":"Stężenie wielopierścieniowych węglowodorów aromatycznych\nZakres:\nnaftalen (0,0020 – 100) μg/dm3\nantracen (0,0010 – 100) μg/dm3\nfluoranten (0,0020 – 100) μg/dm3\nbenzo(b)fluoranten\nZakres (0,0010 – 100) μg/dm3\nbenzo(k)fluoranten (0,0005 – 50) μg/dm3\nbenzo(a)piren (0,0010 – 100) μg/dm3\ndibenzo(ah)antracen (0,001 – 100) μg/dm3\nbenzo(ghi)perylen (0,0014 – 100) μg/dm3\nindeno (1,2,3-cd)piren\n(0,001 – 100) μg/dm3\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluoroscencyjną (HPLC-FLD)","reference":"PB-072/WA wydanie 1 z dnia 28.09.2020 r.","norm_bases":["PB-072/WA wydanie 1 z dnia 28.09.2020 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie wielopierścieniowych węglowodorów aromatycznych\nZakres:\nnaftalen (0,0020 – 100) μg/dm3\nantracen (0,0010 – 100) μg/dm3\nfluoranten (0,0020 – 100) μg/dm3\nbenzo(b)fluoranten\nZakres (0,0010 – 100) μg/dm3\nbenzo(k)fluoranten (0,0005 – 50) μg/dm3\nbenzo(a)piren (0,0010 – 100) μg/dm3\ndibenzo(ah)antracen (0,001 – 100) μg/dm3\nbenzo(ghi)perylen (0,0014 – 100) μg/dm3\nindeno (1,2,3-cd)piren\n(0,001 – 100) μg/dm3\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluoroscencyjną (HPLC-FLD) PB-072/WA wydanie 1 z dnia 28.09.2020 r. Woda, Scieki Stezenie wielopierscieniowych weglowodorow aromatycznych\nZakres:\nnaftalen (0,0020 – 100) μg/dm3\nantracen (0,0010 – 100) μg/dm3\nfluoranten (0,0020 – 100) μg/dm3\nbenzo(b)fluoranten\nZakres (0,0010 – 100) μg/dm3\nbenzo(k)fluoranten (0,0005 – 50) μg/dm3\nbenzo(a)piren (0,0010 – 100) μg/dm3\ndibenzo(ah)antracen (0,001 – 100) μg/dm3\nbenzo(ghi)perylen (0,0014 – 100) μg/dm3\nindeno (1,2,3-cd)piren\n(0,001 – 100) μg/dm3\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluoroscencyjna (HPLC-FLD) PB-072/WA wydanie 1 z dnia 28.09.2020 r.","categories":["water"],"row_index":154,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Concentration of polycyclic aromatic hydrocarbons High-performance liquid chromatography with fluorescence detection (HPLC-FLD) naphthalene anthracene fluoranthene benzo(b)fluoranthene Range benzo(k)fluoranthene benzo(a)pyrene dibenzo(ah)anthracene benzo(ghi)perylene indeno (0,001 – 100) μg/dm3 PB-072/WA wydanie 1 z dnia 28.09.2020 r.","parameters_zh":[{"name":"萘","range":"(0,0020 – 100) μg/dm3"},{"name":"蒽","range":"(0,0010 – 100) μg/dm3"},{"name":"荧蒽","range":"(0,0020 – 100) μg/dm3"},{"name":"苯并（b）荧蒽"},{"name":"范围","range":"(0,0010 – 100) μg/dm3"},{"name":"苯并（k）荧蒽","range":"(0,0005 – 50) μg/dm3"},{"name":"苯并（a）芘","range":"(0,0010 – 100) μg/dm3"},{"name":"二苯并(ah)蒽","range":"(0,001 – 100) μg/dm3"},{"name":"苯并（ghi）苝","range":"(0,0014 – 100) μg/dm3"},{"name":"茚","range":"(1,2,3-cd)piren"},{"name":"(0,001 – 100) μg/dm3"}],"search_zh":"水、污水 多环芳烃浓度 萘 蒽 荧蒽 苯并（b）荧蒽 范围 苯并（k）荧蒽 苯并（a）芘 二苯并(ah)蒽 苯并（ghi）苝 茚 PB-072/WA wydanie 1 z dnia 28.09.2020 r.","test_object_zh":"水、污水","methodology_zh":"多环芳烃浓度"},{"_id":"6a5dc9adf1c10c8ce825ac2c","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie węglowodorów aromatycznych (BTEX)","methodology_en":"Aromatic hydrocarbons (BTEX) concentration","parameters":[{"name":"benzen","range":"(1,5 – 10 000) μg/dm3"},{"name":"toluen","range":"(1,5 – 10 000) μg/dm3"},{"name":"etylobenzen","range":"(1,5 – 10 000) μg/dm3"},{"name":"mp-ksylen","range":"(1,5 – 10 000) μg/dm3"},{"name":"o-ksylen","range":"(1,5 – 10 000) μg/dm3"},{"name":"styren","range":"(1,5 – 10 000) μg/dm3"}],"parameters_en":[{"name":"benzene","range":"(1,5 – 10 000) μg/dm3"},{"name":"toluene","range":"(1,5 – 10 000) μg/dm3"},{"name":"ethylbenzene","range":"(1,5 – 10 000) μg/dm3"},{"name":"mp-xylene","range":"(1,5 – 10 000) μg/dm3"},{"name":"o-xylene","range":"(1,5 – 10 000) μg/dm3"},{"name":"styrene","range":"(1,5 – 10 000) μg/dm3"}],"technique":"Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID)","techniques":["Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID)"],"technique_en":"Headspace gas chromatography with flame ionization detection (HS-GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie węglowodorów aromatycznych (BTEX)\nZakres:\nbenzen (1,5 – 10 000) μg/dm3\ntoluen (1,5 – 10 000) μg/dm3\netylobenzen (1,5 – 10 000) μg/dm3\nmp-ksylen (1,5 – 10 000) μg/dm3\no-ksylen (1,5 – 10 000) μg/dm3\nstyren (1,5 – 10 000) μg/dm3\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID)","reference":"PN-ISO 11423-1:2002","norm_bases":["PN-ISO 11423-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie węglowodorów aromatycznych (BTEX)\nZakres:\nbenzen (1,5 – 10 000) μg/dm3\ntoluen (1,5 – 10 000) μg/dm3\netylobenzen (1,5 – 10 000) μg/dm3\nmp-ksylen (1,5 – 10 000) μg/dm3\no-ksylen (1,5 – 10 000) μg/dm3\nstyren (1,5 – 10 000) μg/dm3\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID) PN-ISO 11423-1:2002 Woda, Scieki Stezenie weglowodorow aromatycznych (BTEX)\nZakres:\nbenzen (1,5 – 10 000) μg/dm3\ntoluen (1,5 – 10 000) μg/dm3\netylobenzen (1,5 – 10 000) μg/dm3\nmp-ksylen (1,5 – 10 000) μg/dm3\no-ksylen (1,5 – 10 000) μg/dm3\nstyren (1,5 – 10 000) μg/dm3\nMetoda chromatografii gazowej z analiza fazy nadpowierzchniowej i detekcja plomieniowo-jonizacyjna (HS-GC-FID) PN-ISO 11423-1:2002","categories":["water"],"row_index":155,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Aromatic hydrocarbons (BTEX) concentration Headspace gas chromatography with flame ionization detection (HS-GC-FID) benzene toluene ethylbenzene mp-xylene o-xylene styrene PN-ISO 11423-1:2002","search_zh":"水、污水 芳香烃（BTEX）浓度 顶空气相色谱-火焰离子化检测法（HS-GC-FID） 苯 甲苯 乙苯 邻二甲苯 苯乙烯 PN-ISO 11423-1:2002","test_object_zh":"水、污水","parameters_zh":[{"name":"苯","range":"(1,5 – 10 000) μg/dm3"},{"name":"甲苯","range":"(1,5 – 10 000) μg/dm3"},{"name":"乙苯","range":"(1,5 – 10 000) μg/dm3"},{"name":"mp-ksylen","range":"(1,5 – 10 000) μg/dm3"},{"name":"邻二甲苯","range":"(1,5 – 10 000) μg/dm3"},{"name":"苯乙烯","range":"(1,5 – 10 000) μg/dm3"}],"technique_zh":"顶空气相色谱-火焰离子化检测法（HS-GC-FID）","methodology_zh":"芳香烃（BTEX）浓度"},{"_id":"6a5dc9adf1c10c8ce825ac2d","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Suma BTEX (z obliczeń)","methodology_en":"Sum of BTEX (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Suma BTEX (z obliczeń)","reference":"PN-ISO 11423-1:2002","norm_bases":["PN-ISO 11423-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Suma BTEX (z obliczeń) PN-ISO 11423-1:2002 Woda, Scieki Suma BTEX (z obliczen) PN-ISO 11423-1:2002","categories":["water"],"row_index":156,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Sum of BTEX (calculated) PN-ISO 11423-1:2002","search_zh":"水、污水 BTEX 总量（由计算得出） PN-ISO 11423-1:2002","test_object_zh":"水、污水","methodology_zh":"BTEX 总量（由计算得出）"},{"_id":"6a5dc9adf1c10c8ce825ac2e","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Stężenie węglowodorów aromatycznych (BTEX)","methodology_en":"Aromatic hydrocarbons (BTEX) concentration","parameters":[{"name":"benzen","range":"(0,075 – 200) mg/kg"},{"name":"toluen","range":"(0,075 – 200) mg/kg"},{"name":"etylobenzen","range":"(0,075 – 200) mg/kg"},{"name":"mp-ksylen","range":"(0,075 – 200) mg/kg"},{"name":"o-ksylen","range":"(0,075 – 200) mg/kg"},{"name":"styren","range":"(0,075 – 200) mg/kg"}],"parameters_en":[{"name":"benzene","range":"(0,075 – 200) mg/kg"},{"name":"toluene","range":"(0,075 – 200) mg/kg"},{"name":"ethylbenzene","range":"(0,075 – 200) mg/kg"},{"name":"mp-xylene","range":"(0,075 – 200) mg/kg"},{"name":"o-xylene","range":"(0,075 – 200) mg/kg"},{"name":"styrene","range":"(0,075 – 200) mg/kg"}],"technique":"Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID)","techniques":["Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID)"],"technique_en":"Headspace gas chromatography with flame ionization detection (HS-GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie węglowodorów aromatycznych (BTEX)\nZakres:\nbenzen (0,075 – 200) mg/kg\ntoluen (0,075 – 200) mg/kg\netylobenzen (0,075 – 200) mg/kg\nmp-ksylen (0,075 – 200) mg/kg\no-ksylen (0,075 – 200) mg/kg\nstyren (0,075 – 200) mg/kg\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID)","reference":"PN-EN ISO 22155:2016-07","norm_bases":["PN-EN ISO 22155:2016-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Stężenie węglowodorów aromatycznych (BTEX)\nZakres:\nbenzen (0,075 – 200) mg/kg\ntoluen (0,075 – 200) mg/kg\netylobenzen (0,075 – 200) mg/kg\nmp-ksylen (0,075 – 200) mg/kg\no-ksylen (0,075 – 200) mg/kg\nstyren (0,075 – 200) mg/kg\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID) PN-EN ISO 22155:2016-07 Gleba Stezenie weglowodorow aromatycznych (BTEX)\nZakres:\nbenzen (0,075 – 200) mg/kg\ntoluen (0,075 – 200) mg/kg\netylobenzen (0,075 – 200) mg/kg\nmp-ksylen (0,075 – 200) mg/kg\no-ksylen (0,075 – 200) mg/kg\nstyren (0,075 – 200) mg/kg\nMetoda chromatografii gazowej z analiza fazy nadpowierzchniowej i detekcja plomieniowo-jonizacyjna (HS-GC-FID) PN-EN ISO 22155:2016-07","categories":["environment"],"row_index":157,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Soil Aromatic hydrocarbons (BTEX) concentration Headspace gas chromatography with flame ionization detection (HS-GC-FID) benzene toluene ethylbenzene mp-xylene o-xylene styrene PN-EN ISO 22155:2016-07","search_zh":"土壤 芳香烃（BTEX）浓度 顶空气相色谱-火焰离子化检测法（HS-GC-FID） 苯 甲苯 乙苯 邻二甲苯 苯乙烯 PN-EN ISO 22155:2016-07","test_object_zh":"土壤","parameters_zh":[{"name":"苯","range":"(0,075 – 200) mg/kg"},{"name":"甲苯","range":"(0,075 – 200) mg/kg"},{"name":"乙苯","range":"(0,075 – 200) mg/kg"},{"name":"mp-ksylen","range":"(0,075 – 200) mg/kg"},{"name":"邻二甲苯","range":"(0,075 – 200) mg/kg"},{"name":"苯乙烯","range":"(0,075 – 200) mg/kg"}],"technique_zh":"顶空气相色谱-火焰离子化检测法（HS-GC-FID）","methodology_zh":"芳香烃（BTEX）浓度"},{"_id":"6a5dc9adf1c10c8ce825ac2f","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Suma BTEX (z obliczeń)","methodology_en":"Sum of BTEX (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Suma BTEX (z obliczeń)","reference":"PN-EN ISO 22155:2016-07","norm_bases":["PN-EN ISO 22155:2016-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Suma BTEX (z obliczeń) PN-EN ISO 22155:2016-07 Gleba Suma BTEX (z obliczen) PN-EN ISO 22155:2016-07","categories":["environment"],"row_index":158,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Soil Sum of BTEX (calculated) PN-EN ISO 22155:2016-07","search_zh":"土壤 BTEX 总量（由计算得出） PN-EN ISO 22155:2016-07","test_object_zh":"土壤","methodology_zh":"BTEX 总量（由计算得出）"},{"_id":"6a5dc9adf1c10c8ce825ac30","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Zawartość suchej masy / zawartość wody","methodology_en":"Dry matter content / water content","parameters":[{"name":"Zakres","range":"(0,1 – 99,9) %"}],"parameters_en":[{"name":"Range","range":"(0,1 – 99,9) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość suchej masy / zawartość wody\nZakres (0,1 – 99,9) %\nMetoda wagowa","reference":"PN-ISO 11465:1999","norm_bases":["PN-ISO 11465:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Zawartość suchej masy / zawartość wody\nZakres (0,1 – 99,9) %\nMetoda wagowa PN-ISO 11465:1999 Gleba Zawartosc suchej masy / zawartosc wody\nZakres (0,1 – 99,9) %\nMetoda wagowa PN-ISO 11465:1999","categories":["water","environment"],"row_index":159,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Soil Dry matter content / water content Gravimetric method Range PN-ISO 11465:1999","parameters_zh":[{"name":"范围","range":"(0,1 – 99,9) %"}],"search_zh":"土壤 干物质含量/水分含量 重量法 范围 PN-ISO 11465:1999","technique_zh":"重量法","test_object_zh":"土壤","methodology_zh":"干物质含量/水分含量"},{"_id":"6a5dc9adf1c10c8ce825ac31","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"3,0 – 11,0"}],"parameters_en":[{"name":"Range","range":"3,0 – 11,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 3,0 – 11,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba pH\nZakres 3,0 – 11,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 Gleba pH\nZakres 3,0 – 11,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["environment"],"row_index":160,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Soil pH Potentiometric method Range PN-EN ISO 10390:2022-09","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"3,0 – 11,0"}],"search_zh":"土壤 pH 值 电位法 范围 PN-EN ISO 10390:2022-09","technique_zh":"电位法","test_object_zh":"土壤"},{"_id":"6a5dc9adf1c10c8ce825ac32","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Stężenie wielopierścieniowych węglowodorów aromatycznych","methodology_en":"Concentration of polycyclic aromatic hydrocarbons","parameters":[{"name":"naftalen","range":"(0,0010 – 100) mg/kg"},{"name":"fenantren","range":"(0,0010 – 100) mg/kg"},{"name":"antracen","range":"(0,0010 – 100) mg/kg"},{"name":"fluoranten","range":"(0,0010 – 100) mg/kg"},{"name":"benzo(a)antracen"},{"name":"Zakres","range":"(0,0010 – 100) mg/kg"},{"name":"chryzen","range":"(0,0010 – 100) mg/kg"},{"name":"benzo(a)fluoranten","range":"(0,0010 – 100) mg/kg"},{"name":"benzo(a)piren","range":"(0,0010 – 100) mg/kg"},{"name":"benzo(ghi)perylen","range":"(0,0010 – 100) mg/kg"},{"name":"benzo(b)fluoranten","range":"(0,0010 – 25) mg/kg"},{"name":"benzo(k)fluoranten","range":"(0,00050 – 25) mg/kg"},{"name":"dibenzo(ah)antracen","range":"(0,0010 – 25) mg/kg"},{"name":"indeno","range":"(1,2,3-cd)piren"},{"name":"(0,0010 – 25) mg/kg"}],"parameters_en":[{"name":"naphthalene","range":"(0,0010 – 100) mg/kg"},{"name":"phenanthrene","range":"(0,0010 – 100) mg/kg"},{"name":"anthracene","range":"(0,0010 – 100) mg/kg"},{"name":"fluoranthene","range":"(0,0010 – 100) mg/kg"},{"name":"benzo(a)anthracene"},{"name":"Range","range":"(0,0010 – 100) mg/kg"},{"name":"chrysene","range":"(0,0010 – 100) mg/kg"},{"name":"benzo(a)fluoranthene","range":"(0,0010 – 100) mg/kg"},{"name":"benzo(a)pyrene","range":"(0,0010 – 100) mg/kg"},{"name":"benzo(ghi)perylene","range":"(0,0010 – 100) mg/kg"},{"name":"benzo(b)fluoranthene","range":"(0,0010 – 25) mg/kg"},{"name":"benzo(k)fluoranthene","range":"(0,00050 – 25) mg/kg"},{"name":"dibenzo(ah)anthracene","range":"(0,0010 – 25) mg/kg"},{"name":"indeno","range":"(1,2,3-cd)piren"},{"name":"(0,0010 – 25) mg/kg"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluoroscencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluoroscencyjną (HPLC-FLD)"],"technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD)","computed":[],"computed_en":[],"activity":"Stężenie wielopierścieniowych węglowodorów aromatycznych\nZakres:\nnaftalen (0,0010 – 100) mg/kg\nfenantren (0,0010 – 100) mg/kg\nantracen (0,0010 – 100) mg/kg\nfluoranten (0,0010 – 100) mg/kg\nbenzo(a)antracen\nZakres (0,0010 – 100) mg/kg\nchryzen (0,0010 – 100) mg/kg\nbenzo(a)fluoranten (0,0010 – 100) mg/kg\nbenzo(a)piren (0,0010 – 100) mg/kg\nbenzo(ghi)perylen (0,0010 – 100) mg/kg\nbenzo(b)fluoranten (0,0010 – 25) mg/kg\nbenzo(k)fluoranten (0,00050 – 25) mg/kg\ndibenzo(ah)antracen (0,0010 – 25) mg/kg\nindeno (1,2,3-cd)piren\n(0,0010 – 25) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluoroscencyjną (HPLC-FLD)","reference":"PB-072/WA wydanie 1 z dnia 28.09.2020 r.","norm_bases":["PB-072/WA wydanie 1 z dnia 28.09.2020 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Stężenie wielopierścieniowych węglowodorów aromatycznych\nZakres:\nnaftalen (0,0010 – 100) mg/kg\nfenantren (0,0010 – 100) mg/kg\nantracen (0,0010 – 100) mg/kg\nfluoranten (0,0010 – 100) mg/kg\nbenzo(a)antracen\nZakres (0,0010 – 100) mg/kg\nchryzen (0,0010 – 100) mg/kg\nbenzo(a)fluoranten (0,0010 – 100) mg/kg\nbenzo(a)piren (0,0010 – 100) mg/kg\nbenzo(ghi)perylen (0,0010 – 100) mg/kg\nbenzo(b)fluoranten (0,0010 – 25) mg/kg\nbenzo(k)fluoranten (0,00050 – 25) mg/kg\ndibenzo(ah)antracen (0,0010 – 25) mg/kg\nindeno (1,2,3-cd)piren\n(0,0010 – 25) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluoroscencyjną (HPLC-FLD) PB-072/WA wydanie 1 z dnia 28.09.2020 r. Gleba Stezenie wielopierscieniowych weglowodorow aromatycznych\nZakres:\nnaftalen (0,0010 – 100) mg/kg\nfenantren (0,0010 – 100) mg/kg\nantracen (0,0010 – 100) mg/kg\nfluoranten (0,0010 – 100) mg/kg\nbenzo(a)antracen\nZakres (0,0010 – 100) mg/kg\nchryzen (0,0010 – 100) mg/kg\nbenzo(a)fluoranten (0,0010 – 100) mg/kg\nbenzo(a)piren (0,0010 – 100) mg/kg\nbenzo(ghi)perylen (0,0010 – 100) mg/kg\nbenzo(b)fluoranten (0,0010 – 25) mg/kg\nbenzo(k)fluoranten (0,00050 – 25) mg/kg\ndibenzo(ah)antracen (0,0010 – 25) mg/kg\nindeno (1,2,3-cd)piren\n(0,0010 – 25) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluoroscencyjna (HPLC-FLD) PB-072/WA wydanie 1 z dnia 28.09.2020 r.","categories":["environment"],"row_index":161,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Soil Concentration of polycyclic aromatic hydrocarbons High-performance liquid chromatography with fluorescence detection (HPLC-FLD) naphthalene phenanthrene anthracene fluoranthene benzo(a)anthracene Range chrysene benzo(a)fluoranthene benzo(a)pyrene benzo(ghi)perylene benzo(b)fluoranthene benzo(k)fluoranthene dibenzo(ah)anthracene indeno (0,0010 – 25) mg/kg PB-072/WA wydanie 1 z dnia 28.09.2020 r.","parameters_zh":[{"name":"萘","range":"(0,0010 – 100) mg/kg"},{"name":"菲","range":"(0,0010 – 100) mg/kg"},{"name":"蒽","range":"(0,0010 – 100) mg/kg"},{"name":"荧蒽","range":"(0,0010 – 100) mg/kg"},{"name":"苯并（a）蒽"},{"name":"范围","range":"(0,0010 – 100) mg/kg"},{"name":"䓛","range":"(0,0010 – 100) mg/kg"},{"name":"苯并(a)荧蒽","range":"(0,0010 – 100) mg/kg"},{"name":"苯并（a）芘","range":"(0,0010 – 100) mg/kg"},{"name":"苯并（ghi）苝","range":"(0,0010 – 100) mg/kg"},{"name":"苯并（b）荧蒽","range":"(0,0010 – 25) mg/kg"},{"name":"苯并（k）荧蒽","range":"(0,00050 – 25) mg/kg"},{"name":"二苯并(ah)蒽","range":"(0,0010 – 25) mg/kg"},{"name":"茚","range":"(1,2,3-cd)piren"},{"name":"(0,0010 – 25) mg/kg"}],"search_zh":"土壤 多环芳烃浓度 萘 菲 蒽 荧蒽 苯并（a）蒽 范围 䓛 苯并(a)荧蒽 苯并（a）芘 苯并（ghi）苝 苯并（b）荧蒽 苯并（k）荧蒽 二苯并(ah)蒽 茚 PB-072/WA wydanie 1 z dnia 28.09.2020 r.","test_object_zh":"土壤","methodology_zh":"多环芳烃浓度"},{"_id":"6a5dc9adf1c10c8ce825ac33","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Obecność i liczba żywych jaj pasożytów jelitowych Ascaris sp.,Toxocara sp., Trichuris sp.,","methodology_en":"Presence and count of viable eggs of intestinal parasites Ascaris sp.,Toxocara sp., Trichuris sp.,","parameters":[{"name":"Zakres","range":"od 1 jaja/ dm3"}],"parameters_en":[{"name":"Range","range":"od 1 jaja/ dm3"}],"technique":"Metoda flotacji, mikroskopowa","techniques":["Metoda flotacji, mikroskopowa"],"technique_en":"Flotation method, microscopic","computed":[],"computed_en":[],"activity":"Obecność i liczba żywych jaj pasożytów jelitowych Ascaris sp.,Toxocara sp., Trichuris sp.,\nZakres od 1 jaja/ dm3\nMetoda flotacji, mikroskopowa","reference":"PB-073/WA wydanie 2 z dnia 30.05.2022r.","norm_bases":["PB-073/WA wydanie 2 z dnia 30.05.2022r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Obecność i liczba żywych jaj pasożytów jelitowych Ascaris sp.,Toxocara sp., Trichuris sp.,\nZakres od 1 jaja/ dm3\nMetoda flotacji, mikroskopowa PB-073/WA wydanie 2 z dnia 30.05.2022r. Scieki Obecnosc i liczba zywych jaj pasozytow jelitowych Ascaris sp.,Toxocara sp., Trichuris sp.,\nZakres od 1 jaja/ dm3\nMetoda flotacji, mikroskopowa PB-073/WA wydanie 2 z dnia 30.05.2022r.","categories":["water","food"],"row_index":162,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Presence and count of viable eggs of intestinal parasites Ascaris sp.,Toxocara sp., Trichuris sp., Flotation method, microscopic Range PB-073/WA wydanie 2 z dnia 30.05.2022r.","parameters_zh":[{"name":"范围","range":"od 1 jaja/ dm3"}],"search_zh":"污水 肠道寄生虫 Ascaris sp.、Toxocara sp.、Trichuris sp. 活卵的检出与计数 浮选显微镜法 范围 PB-073/WA wydanie 2 z dnia 30.05.2022r.","test_object_zh":"污水","technique_zh":"浮选显微镜法","methodology_zh":"肠道寄生虫 Ascaris sp.、Toxocara sp.、Trichuris sp. 活卵的检出与计数"},{"_id":"6a5dc9adf1c10c8ce825ac34","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Obecność i liczba żywych jaj pasożytów jelitowych Ascaris sp.,Toxocara sp., Trichuris sp.,","methodology_en":"Presence and count of viable eggs of intestinal parasites Ascaris sp.,Toxocara sp., Trichuris sp.,","parameters":[{"name":"Zakres","range":"od 20 jaj/ kg"}],"parameters_en":[{"name":"Range","range":"od 20 jaj/ kg"}],"technique":"Metoda flotacji, mikroskopowa","techniques":["Metoda flotacji, mikroskopowa"],"technique_en":"Flotation method, microscopic","computed":[],"computed_en":[],"activity":"Obecność i liczba żywych jaj pasożytów jelitowych Ascaris sp.,Toxocara sp., Trichuris sp.,\nZakres od 20 jaj/ kg\nMetoda flotacji, mikroskopowa","reference":"PB-09/CLB wydanie 1 z dnia 30.05.2022r.","norm_bases":["PB-09/CLB wydanie 1 z dnia 30.05.2022r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Obecność i liczba żywych jaj pasożytów jelitowych Ascaris sp.,Toxocara sp., Trichuris sp.,\nZakres od 20 jaj/ kg\nMetoda flotacji, mikroskopowa PB-09/CLB wydanie 1 z dnia 30.05.2022r. Osady sciekowe Obecnosc i liczba zywych jaj pasozytow jelitowych Ascaris sp.,Toxocara sp., Trichuris sp.,\nZakres od 20 jaj/ kg\nMetoda flotacji, mikroskopowa PB-09/CLB wydanie 1 z dnia 30.05.2022r.","categories":["water"],"row_index":163,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge Presence and count of viable eggs of intestinal parasites Ascaris sp.,Toxocara sp., Trichuris sp., Flotation method, microscopic Range PB-09/CLB wydanie 1 z dnia 30.05.2022r.","parameters_zh":[{"name":"范围","range":"od 20 jaj/ kg"}],"search_zh":"污泥 肠道寄生虫 Ascaris sp.、Toxocara sp.、Trichuris sp. 活卵的检出与计数 浮选显微镜法 范围 PB-09/CLB wydanie 1 z dnia 30.05.2022r.","test_object_zh":"污泥","technique_zh":"浮选显微镜法","methodology_zh":"肠道寄生虫 Ascaris sp.、Toxocara sp.、Trichuris sp. 活卵的检出与计数"},{"_id":"6a5dc9adf1c10c8ce825ac35","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Sucha pozostałość / zawartość wody/sucha masa","methodology_en":"Dry residue / water content/dry matter","parameters":[{"name":"Zakres","range":"(0,1 – 99,9) %"}],"parameters_en":[{"name":"Range","range":"(0,1 – 99,9) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Sucha pozostałość / zawartość wody/sucha masa\nZakres (0,1 – 99,9) %\nMetoda wagowa","reference":"PN-EN 12880:2004","norm_bases":["PN-EN 12880:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Sucha pozostałość / zawartość wody/sucha masa\nZakres (0,1 – 99,9) %\nMetoda wagowa PN-EN 12880:2004 Osady sciekowe Sucha pozostalosc / zawartosc wody/sucha masa\nZakres (0,1 – 99,9) %\nMetoda wagowa PN-EN 12880:2004","categories":["water"],"row_index":164,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge Dry residue / water content/dry matter Gravimetric method Range PN-EN 12880:2004","parameters_zh":[{"name":"范围","range":"(0,1 – 99,9) %"}],"search_zh":"污泥 重量法 范围 PN-EN 12880:2004","technique_zh":"重量法","test_object_zh":"污泥"},{"_id":"6a5dc9adf1c10c8ce825ac36","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"3,0 – 11,0"}],"parameters_en":[{"name":"Range","range":"3,0 – 11,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 3,0 – 11,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe pH\nZakres 3,0 – 11,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 Osady sciekowe pH\nZakres 3,0 – 11,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["water"],"row_index":165,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge pH Potentiometric method Range PN-EN ISO 10390:2022-09","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"3,0 – 11,0"}],"search_zh":"污泥 pH 值 电位法 范围 PN-EN ISO 10390:2022-09","technique_zh":"电位法","test_object_zh":"污泥"},{"_id":"6a5dc9adf1c10c8ce825ac37","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Strata przy prażeniu / substancje organiczne","methodology_en":"Loss on ignition / organic matter","parameters":[{"name":"Zakres","range":"(10 – 90) %"}],"parameters_en":[{"name":"Range","range":"(10 – 90) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Strata przy prażeniu / substancje organiczne\nZakres (10 – 90) %\nMetoda wagowa","reference":"PN-EN 15935:2022-01","norm_bases":["PN-EN 15935:2022-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Strata przy prażeniu / substancje organiczne\nZakres (10 – 90) %\nMetoda wagowa PN-EN 15935:2022-01 Osady sciekowe Strata przy prazeniu / substancje organiczne\nZakres (10 – 90) %\nMetoda wagowa PN-EN 15935:2022-01","categories":["water"],"row_index":166,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge Loss on ignition / organic matter Gravimetric method Range PN-EN 15935:2022-01","parameters_zh":[{"name":"范围","range":"(10 – 90) %"}],"search_zh":"污泥 重量法 范围 PN-EN 15935:2022-01","technique_zh":"重量法","test_object_zh":"污泥"},{"_id":"6a5dc9adf1c10c8ce825ac38","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie / zawartość węglowodorów aromatycznych","methodology_en":"Concentration / content of aromatic hydrocarbons","parameters":[{"name":"benzen (0,50 – 20000) μg w próbce"},{"name":"Zakres","range":"(0,0333 – 1333) mg/m3"},{"name":"toluen (0,50 – 20000) μg w próbce","range":"(0,0333 – 1333) mg/m3"},{"name":"etylobenzen (0,50 – 20000) μg w próbce","range":"(0,0333 – 1333) mg/m3"},{"name":"ksylen (0,50 – 20000) μg w próbce","range":"(0,0333 – 1333) mg/m3"},{"name":"octan etylu (1,0 – 20000) μg w próbce","range":"(0,0667 – 1333) mg/m3"},{"name":"octan butylu (1,0 – 20000) μg w próbce","range":"(0,0667 – 1333) mg/m3"},{"name":"styren (0,50 – 20000) μg w próbce","range":"(0,0333 – 1333) mg/m3"},{"name":"aceton (5,0 – 20000) μg w próbce","range":"(0,333 – 1333) mg/m3"}],"parameters_en":[{"name":"benzene (0,50 – 20000) μg in the sample"},{"name":"Range","range":"(0,0333 – 1333) mg/m3"},{"name":"toluene (0,50 – 20000) μg per sample","range":"(0,0333 – 1333) mg/m3"},{"name":"ethylbenzene (0,50 – 20000) μg in sample","range":"(0,0333 – 1333) mg/m3"},{"name":"xylene (0,50 – 20000) μg in sample","range":"(0,0333 – 1333) mg/m3"},{"name":"ethyl acetate (1,0 – 20000) μg in sample","range":"(0,0667 – 1333) mg/m3"},{"name":"butyl acetate (1,0 – 20000) μg in sample","range":"(0,0667 – 1333) mg/m3"},{"name":"styrene (0,50 – 20000) μg per sample","range":"(0,0333 – 1333) mg/m3"},{"name":"acetone (5,0 – 20000) μg in the sample","range":"(0,333 – 1333) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie / zawartość węglowodorów aromatycznych\nZakres:\nbenzen (0,50 – 20000) μg w próbce\nZakres (0,0333 – 1333) mg/m3\ntoluen (0,50 – 20000) μg w próbce (0,0333 – 1333) mg/m3\netylobenzen (0,50 – 20000) μg w próbce (0,0333 – 1333) mg/m3\nksylen (0,50 – 20000) μg w próbce (0,0333 – 1333) mg/m3\noctan etylu (1,0 – 20000) μg w próbce (0,0667 – 1333) mg/m3\noctan butylu (1,0 – 20000) μg w próbce (0,0667 – 1333) mg/m3\nstyren (0,50 – 20000) μg w próbce (0,0333 – 1333) mg/m3\naceton (5,0 – 20000) μg w próbce (0,333 – 1333) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie / zawartość węglowodorów aromatycznych\nZakres:\nbenzen (0,50 – 20000) μg w próbce\nZakres (0,0333 – 1333) mg/m3\ntoluen (0,50 – 20000) μg w próbce (0,0333 – 1333) mg/m3\netylobenzen (0,50 – 20000) μg w próbce (0,0333 – 1333) mg/m3\nksylen (0,50 – 20000) μg w próbce (0,0333 – 1333) mg/m3\noctan etylu (1,0 – 20000) μg w próbce (0,0667 – 1333) mg/m3\noctan butylu (1,0 – 20000) μg w próbce (0,0667 – 1333) mg/m3\nstyren (0,50 – 20000) μg w próbce (0,0333 – 1333) mg/m3\naceton (5,0 – 20000) μg w próbce (0,333 – 1333) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie / zawartosc weglowodorow aromatycznych\nZakres:\nbenzen (0,50 – 20000) μg w probce\nZakres (0,0333 – 1333) mg/m3\ntoluen (0,50 – 20000) μg w probce (0,0333 – 1333) mg/m3\netylobenzen (0,50 – 20000) μg w probce (0,0333 – 1333) mg/m3\nksylen (0,50 – 20000) μg w probce (0,0333 – 1333) mg/m3\noctan etylu (1,0 – 20000) μg w probce (0,0667 – 1333) mg/m3\noctan butylu (1,0 – 20000) μg w probce (0,0667 – 1333) mg/m3\nstyren (0,50 – 20000) μg w probce (0,0333 – 1333) mg/m3\naceton (5,0 – 20000) μg w probce (0,333 – 1333) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":167,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Concentration / content of aromatic hydrocarbons Gas chromatography with flame ionization detection (GC-FID) benzene (0,50 – 20000) μg in the sample Range toluene (0,50 – 20000) μg per sample ethylbenzene (0,50 – 20000) μg in sample xylene (0,50 – 20000) μg in sample ethyl acetate (1,0 – 20000) μg in sample butyl acetate (1,0 – 20000) μg in sample styrene (0,50 – 20000) μg per sample acetone (5,0 – 20000) μg in the sample PN-EN 13649:2005","parameters_zh":[{"name":"benzen (0,50 – 20000) μg w próbce"},{"name":"范围","range":"(0,0333 – 1333) mg/m3"},{"name":"toluen (0,50 – 20000) μg w próbce","range":"(0,0333 – 1333) mg/m3"},{"name":"etylobenzen (0,50 – 20000) μg w próbce","range":"(0,0333 – 1333) mg/m3"},{"name":"ksylen (0,50 – 20000) μg w próbce","range":"(0,0333 – 1333) mg/m3"},{"name":"octan etylu (1,0 – 20000) μg w próbce","range":"(0,0667 – 1333) mg/m3"},{"name":"octan butylu (1,0 – 20000) μg w próbce","range":"(0,0667 – 1333) mg/m3"},{"name":"styren (0,50 – 20000) μg w próbce","range":"(0,0333 – 1333) mg/m3"},{"name":"aceton (5,0 – 20000) μg w próbce","range":"(0,333 – 1333) mg/m3"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a5dc9adf1c10c8ce825ac39","lab_id":"69ad52a3de79e566650fb1bb","country":"PL","accr_number":"AB 322","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie / zawartość węglowodorów alifatycznych (C6-C14)","methodology_en":"Concentration / content of aliphatic hydrocarbons (C6-C14)","parameters":[{"name":"heksan (1,0 – 20000) μg w próbce"},{"name":"Zakres","range":"(0,0667 – 1333) mg/m3"},{"name":"heptan, oktan, nonan, dekan, undekan, dodekan, tridekan, tetradekan (0,50 – 20000) μg w próbce","range":"(0,0333 – 1333) mg/m3"}],"parameters_en":[{"name":"hexane (1,0 – 20000) μg in sample"},{"name":"Range","range":"(0,0667 – 1333) mg/m3"},{"name":"heptane, octane, nonane, decane, undecane, dodecane, tridecane, tetradecane (0,50 – 20000) μg in sample","range":"(0,0333 – 1333) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie / zawartość węglowodorów alifatycznych (C6-C14)\nZakres:\nheksan (1,0 – 20000) μg w próbce\nZakres (0,0667 – 1333) mg/m3\nheptan, oktan, nonan, dekan, undekan, dodekan, tridekan, tetradekan (0,50 – 20000) μg w próbce (0,0333 – 1333) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie / zawartość węglowodorów alifatycznych (C6-C14)\nZakres:\nheksan (1,0 – 20000) μg w próbce\nZakres (0,0667 – 1333) mg/m3\nheptan, oktan, nonan, dekan, undekan, dodekan, tridekan, tetradekan (0,50 – 20000) μg w próbce (0,0333 – 1333) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie / zawartosc weglowodorow alifatycznych (C6-C14)\nZakres:\nheksan (1,0 – 20000) μg w probce\nZakres (0,0667 – 1333) mg/m3\nheptan, oktan, nonan, dekan, undekan, dodekan, tridekan, tetradekan (0,50 – 20000) μg w probce (0,0333 – 1333) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":168,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Concentration / content of aliphatic hydrocarbons (C6-C14) Gas chromatography with flame ionization detection (GC-FID) hexane (1,0 – 20000) μg in sample Range heptane, octane, nonane, decane, undecane, dodecane, tridecane, tetradecane (0,50 – 20000) μg in sample PN-EN 13649:2005","parameters_zh":[{"name":"heksan (1,0 – 20000) μg w próbce"},{"name":"范围","range":"(0,0667 – 1333) mg/m3"},{"name":"heptan, oktan, nonan, dekan, undekan, dodekan, tridekan, tetradekan (0,50 – 20000) μg w próbce","range":"(0,0333 – 1333) mg/m3"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"}],"has_pdf":true}