{"lab":{"_id":"69ad52a3de79e566650fb1b5","accr_number":"AB 313","country":"PL","accr_body":"PCA","address":"Al. Jerozolimskie 146A, 02-305 Warszawa, LABORATORIUM SGS POLSKA, ul. Cieszyńska 52 A","categories":["water","environment","food","petro","microbiology","materials","pharma"],"city":"Warszawa","imported_at":"2026-03-08T10:42:43.265Z","methods_count":610,"name":"SGS POLSKA Sp. z o.o.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_313.pdf"],"scope_summary":"","search_text":"sgs polska sp. z o.o. al. jerozolimskie 146a, 02-305 warszawa, laboratorium sgs polska, ul. cieszyńska 52 a materials petro other pharma automotive environment water food microbiology metrology electronics construction","status":"active","updated_at":"2026-03-08T14:51:09.916Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-17T20:07:08.510Z","location":{"type":"Point","coordinates":[21.0122,52.2297]},"email_confidence":"high","email_mx":true,"email_source":"https://www.pca.gov.pl/akredytowane-podmioty/akredytacje-aktywne/laboratoria-badawcze/AB%20313,podmiot.html","fields_of_testing":[{"codes":"B/31/P, B/32/P, B/44/P","pl":"Badania biologiczne i biochemiczne i pobieranie próbek: gleby, odpadów, osadów, środków wspomagających uprawę roślin","en":"Biological and biochemical tests and sampling of soil, waste, sediments, plant conditioners"},{"codes":"B/22, B/43, B/55, B/57","pl":"Badania biologiczne i biochemiczne: żywności, nawozów, pasz dla zwierząt, obiektów z obszaru produkcji żywności","en":"Biological and biochemical tests food, fertilizers, animal feedstuffs, objects from food production area,"},{"codes":"C/33/P","pl":"Badania chemiczne i pobieranie próbek – środowisko pracy (czynniki szkodliwe - powietrze)","en":"Chemical tests and sampling - working environment (harmful factors - air)"},{"codes":"C/1, C/4, C/10, C/22, C/33, C/36, C/43, C/47, C49, C/55,","pl":"Badania chemiczne: produktów rolnych, wyrobów chemicznych, paliw ciekłych, paliw stałych, żywności, próbek powietrza, gazów składowiskowych, nawozów, ropy naftowej, materiały opakowaniowe, pasz dla zwierząt,","en":"Chemical tests of agricultural products chemical products, liquid fuels, solid fuels, food, air samples, landfill gases, fertilizers, crude oil, packaging materials, animal feedstuffs"},{"codes":"C/28/P, C/29/P, C/30/P, C/31/P, C/32/P, C/44/P","pl":"Badania chemiczne i pobieranie próbek wody do spożycia przez ludzi, wody, ścieków, gleby, odpadów, osadów, środków wspomagających uprawę roślin","en":"Chemical tests and sampling of drinking water, water, sewage, soil, waste, sediments, plant conditioners"},{"codes":"G/33, G/34","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki szkodliwe i uciążliwe – hałas, oświetlenie, mikroklimat, wydatek energetyczny, drgania), środowisko ogólne (czynniki fizyczne – hałas)","en":"Tests concerning environmental engineering (environmental and climatic) – working environment (harmful and nuisance factors – noise, lighting, microclimate, energy expenditure, vibration), general environment (physical factors – noise)"},{"codes":"N/4, N/10, N/22, N/36, N/42, N/43, N/46, N/47, N/49; N/55","pl":"Badania właściwości fizycznych: wyrobów chemicznych, paliw stałych, paliw ciekłych, żywności, gazów składowiskowych, kosmetyków, nawozów, materiałów smarnych, ropy naftowej, materiałów opakowaniowych, pasz dla zwierząt","en":"Tests of physical properties of agricultural products, chemical products, liquid fuels, solid fuels, food, landfill gases, cosmetics, fertilizers, lubricants, crude oil, packaging materials, animal feedstuffs"},{"codes":"N/33/P","pl":"Badania właściwości fizycznych i pobieranie próbek – środowisko pracy (czynniki szkodliwe - powietrze)","en":"Tests of physical properties and sampling - working environment (harmful factors - air)"},{"codes":"N/28/P, N/29/P, N/30/P, N/31/P, N/32P, N/44/P","pl":"Badania właściwości fizycznych i pobieranie próbek: wody do spożycia przez ludzi, wody, ścieków, gleby, osadów, odpadów, środków wspomagających uprawę roślin","en":"Tests of physical properties and sampling of drinking water, water, sewage, soil, sediments, waste, plant conditioners"},{"codes":"K/4, K/22, K/30, K/42, K/43, K/55","pl":"Badania mikrobiologiczne: wyrobów chemicznych, żywności, ścieków, kosmetyków, nawozów, pasz dla zwierząt","en":"Microbiological tests of chemical products, food sawage, cosmetics, fertilizers, animal feedstuffs"},{"codes":"K/9/P, K/17/P; K/28/P, K/29/P, K/31/P, K/32/P, K/44/P, K/57/P","pl":"Badania mikrobiologiczne i pobieranie próbek powietrza, wyrobów innych, żywności, wody, wody do spożycia przez ludzi, gleby, osadów, odpadów, środków wspomagających uprawę roślin, obiektów z obszarów produkcji żywności","en":"Microbiological tests and sampling of air, other produkts, water, drinking water, soil, sediments, waste, plant conditioners, objects from food production area"},{"codes":"Q/22, Q49, Q55","pl":"Badania sensoryczne żywności , materiały opakowaniowe, pasze dla zwierząt","en":"Sensory tests of food, packaging materials, animal feedstuffs"},{"codes":"Q/28/P, Q/29/P","pl":"Badania sensoryczne i pobieranie próbek wody, wody do spożycia przez ludzi","en":"Sensory tests and sampling of water, drinking water"},{"codes":"L/8","pl":"Badania nieniszczące wyrobów i materiałów konstrukcyjnych","en":"Non-destructive tests of construction products and materials"},{"codes":"","pl":"Przedmiot badań/wyrób | Rodzaj działalności/badane cechy/metoda | Dokumenty odniesienia","en":"Material/product tested | Type of activity/parameter/characteristic tested | Reference documents"}],"issue":{"no":"43","date":"08.07.2026"},"parse_date":"2026-08-17T20:07:08.510Z","parse_source":"agent-claude-code","flexible_scope":true,"format_family":"section-inline","lab_locations":[{"name":"LABORATORIUM SGS POLSKA","address":"ul. Cieszyńska 52 A","city":null,"postal":null},{"name":"Pracownia Paliw Stałych","address":"ul. Cieszyńska 52 A, 43-200 Pszczyna","city":"Pszczyna","postal":"43-200"},{"name":"Pracownia Produktów Naftowych","address":"ul. Kujawska 6, 80-550 Gdańsk","city":"Gdańsk","postal":"80-550"},{"name":"Pracownia Badań Żywności, Dział Mikrobiologii","address":"ul. Poznańska 305 B, 05-850 Ołtarzew","city":"Ołtarzew","postal":"05-850"},{"name":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","address":"ul. Poznańska 305 B, 05-850 Ołtarzew","city":"Ołtarzew","postal":"05-850"},{"name":"Pracownia Badań Nieniszczących","address":"ul. Jeleniogórska 26, 60-179 Poznań","city":"Poznań","postal":"60-179"},{"name":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","address":"ul. Cieszyńska 52A, 43-200 Pszczyna","city":"Pszczyna","postal":"43-200"},{"name":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii","address":"ul. Cieszyńska 52A, 43-200 Pszczyna","city":"Pszczyna","postal":"43-200"},{"name":"Pracownia Środowiskowa, Dział Analiz Organicznych","address":"ul. Cieszyńska 52A, 43-200 Pszczyna","city":"Pszczyna","postal":"43-200"},{"name":"Pracownia Środowiskowa, Dział Pobierania Próbek","address":"ul. Cieszyńska 52A, 43-200 Pszczyna","city":"Pszczyna","postal":"43-200"},{"name":"Pracownia Środowiskowa, Dział Pomiarów Jakości Środowiska - Stanowiska Pracy","address":"ul. Cieszyńska 52A, 43-200 Pszczyna","city":"Pszczyna","postal":"43-200"},{"name":"Pracownia Badań Żywności, Dział Mikrobiologii","address":null,"city":null,"postal":null},{"name":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","address":null,"city":null,"postal":null},{"name":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii","address":null,"city":null,"postal":null},{"name":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii; Wierzawice 874, 37-300 Leżajsk","address":null,"city":null,"postal":null}],"locations_extracted_at":"2026-07-24T05:06:31.454Z","map_coord":[52.213578,20.953711],"map_geo":"nominatim-street","scope_format":"PCA::pracownie+siatka5","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/a2996986abb02881048c32794a1fb927/AB%20313.pdf","has_en":true,"category_counts":{"water":220,"environment":136,"food":134,"petro":134,"microbiology":89,"other":42,"materials":42,"pharma":37,"construction":2,"metrology":2},"category_scores":{"water":57.76,"environment":22.07,"food":21.43,"petro":21.43,"microbiology":9.45,"other":2.11,"materials":2.11,"pharma":1.63,"construction":0,"metrology":0},"has_zh":true},"methods":[{"_id":"6a8369ecaf14b9c0e7b1dc22","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny, Solid fuels: hard coal","methodology":"Zawartość wilgoci pierwszego stopnia (wilgoci przemijającej)","parameters":[{"name":"Zakres","range":"(0,2 - 30,0) %"},{"name":"First - stage moisture content (transient moisture)"},{"name":"Range","range":"(0,2 - 30,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa","Gravimetric method"],"computed":[],"activity":"Zawartość wilgoci pierwszego stopnia (wilgoci przemijającej)\nZakres:\nZakres (0,2 - 30,0) %\nFirst - stage moisture content (transient moisture)\nRange (0,2 - 30,0) %\nMetoda wagowa","reference":"PN-G-04611:2020-06 | PN-ISO 589:2006 | ISO 589:2008 | ASTM D 3302/D 3302M-17","norm_bases":["PN-G-04611:2020-06","PN-ISO 589:2006","ISO 589:2008","ASTM D 3302/D 3302M-17"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny, Solid fuels: hard coal Zawartość wilgoci pierwszego stopnia (wilgoci przemijającej)\nZakres:\nZakres (0,2 - 30,0) %\nFirst - stage moisture content (transient moisture)\nRange (0,2 - 30,0) %\nMetoda wagowa PN-G-04611:2020-06 | PN-ISO 589:2006 | ISO 589:2008 | ASTM D 3302/D 3302M-17 Paliwa stale: wegiel kamienny, Solid fuels: hard coal Zawartosc wilgoci pierwszego stopnia (wilgoci przemijajacej)\nZakres:\nZakres (0,2 - 30,0) %\nFirst - stage moisture content (transient moisture)\nRange (0,2 - 30,0) %\nMetoda wagowa PN-G-04611:2020-06 | PN-ISO 589:2006 | ISO 589:2008 | ASTM D 3302/D 3302M-17","categories":["petro"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"First-stage moisture content (free moisture)","parameters_en":[{"name":"Range","range":"(0,2 - 30,0) %"},{"name":"First - stage moisture content (transient moisture)"},{"name":"Range","range":"(0,2 - 30,0) %"}],"search_en":"First-stage moisture content (free moisture) Gravimetric method Range Range PN-G-04611:2020-06 | PN-ISO 589:2006 | ISO 589:2008 | ASTM D 3302/D 3302M-17","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(0,2 - 30,0) %"},{"name":"First - stage moisture content (transient moisture)"},{"name":"范围","range":"(0,2 - 30,0) %"}],"search_zh":"第一阶段水分（外在水分）含量 重量法 范围 范围 PN-G-04611:2020-06 | PN-ISO 589:2006 | ISO 589:2008 | ASTM D 3302/D 3302M-17","technique_zh":"重量法","methodology_zh":"第一阶段水分（外在水分）含量"},{"_id":"6a8369ecaf14b9c0e7b1dc23","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny, Solid fuels: hard coal","methodology":"Zawartość wilgoci drugiego stopnia (wilgoci pozostałej w próbce)","parameters":[{"name":"Zakres","range":"(0,4 - 13,0) %"},{"name":"Second - stage moisture content (residual moisture)"},{"name":"Range","range":"(0,4 - 13,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa","Gravimetric method"],"computed":[],"activity":"Zawartość wilgoci drugiego stopnia (wilgoci pozostałej w próbce)\nZakres:\nZakres (0,4 - 13,0) %\nSecond - stage moisture content (residual moisture)\nRange (0,4 - 13,0) %\nMetoda wagowa","reference":"PN-ISO 589:2006 metoda A1 | ISO 589:2008 metoda A1 | PN-ISO 589:2006 A1 method | ISO 589:2008 A1 method","norm_bases":["PN-ISO 589:2006 metoda A1","ISO 589:2008 metoda A1","PN-ISO 589:2006 A1 method","ISO 589:2008 A1 method"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny, Solid fuels: hard coal Zawartość wilgoci drugiego stopnia (wilgoci pozostałej w próbce)\nZakres:\nZakres (0,4 - 13,0) %\nSecond - stage moisture content (residual moisture)\nRange (0,4 - 13,0) %\nMetoda wagowa PN-ISO 589:2006 metoda A1 | ISO 589:2008 metoda A1 | PN-ISO 589:2006 A1 method | ISO 589:2008 A1 method Paliwa stale: wegiel kamienny, Solid fuels: hard coal Zawartosc wilgoci drugiego stopnia (wilgoci pozostalej w probce)\nZakres:\nZakres (0,4 - 13,0) %\nSecond - stage moisture content (residual moisture)\nRange (0,4 - 13,0) %\nMetoda wagowa PN-ISO 589:2006 metoda A1 | ISO 589:2008 metoda A1 | PN-ISO 589:2006 A1 method | ISO 589:2008 A1 method","categories":["petro"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Second-stage moisture content (moisture remaining in the sample)","parameters_en":[{"name":"Range","range":"(0,4 - 13,0) %"},{"name":"Second - stage moisture content (residual moisture)"},{"name":"Range","range":"(0,4 - 13,0) %"}],"search_en":"Second-stage moisture content (moisture remaining in the sample) Gravimetric method Range Range PN-ISO 589:2006 metoda A1 | ISO 589:2008 metoda A1 | PN-ISO 589:2006 A1 method | ISO 589:2008 A1 method","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(0,4 - 13,0) %"},{"name":"Second - stage moisture content (residual moisture)"},{"name":"范围","range":"(0,4 - 13,0) %"}],"search_zh":"第二阶段水分（样品残余水分）含量 重量法 范围 范围 PN-ISO 589:2006 metoda A1 | ISO 589:2008 metoda A1 | PN-ISO 589:2006 A1 method | ISO 589:2008 A1 method","technique_zh":"重量法","methodology_zh":"第二阶段水分（样品残余水分）含量"},{"_id":"6a8369ecaf14b9c0e7b1dc24","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny, Solid fuels: hard coal","methodology":"Zawartość wilgoci całkowitej","parameters":[{"name":"Zakres","range":"(1,0 - 39,0) %"},{"name":"Total moisture content"},{"name":"Range","range":"(1,0 - 39,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa","Gravimetric method"],"computed":[],"activity":"Zawartość wilgoci całkowitej\nZakres:\nZakres (1,0 - 39,0) %\nTotal moisture content\nRange (1,0 - 39,0) %\nMetoda wagowa","reference":"PN-G-04611:2020-06","norm_bases":["PN-G-04611:2020-06"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny, Solid fuels: hard coal Zawartość wilgoci całkowitej\nZakres:\nZakres (1,0 - 39,0) %\nTotal moisture content\nRange (1,0 - 39,0) %\nMetoda wagowa PN-G-04611:2020-06 Paliwa stale: wegiel kamienny, Solid fuels: hard coal Zawartosc wilgoci calkowitej\nZakres:\nZakres (1,0 - 39,0) %\nTotal moisture content\nRange (1,0 - 39,0) %\nMetoda wagowa PN-G-04611:2020-06","categories":["petro"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total moisture content","parameters_en":[{"name":"Range","range":"(1,0 - 39,0) %"},{"name":"Total moisture content"},{"name":"Range","range":"(1,0 - 39,0) %"}],"search_en":"Total moisture content Gravimetric method Range Range PN-G-04611:2020-06","technique_en":"Gravimetric method","methodology_zh":"全水分含量","parameters_zh":[{"name":"范围","range":"(1,0 - 39,0) %"},{"name":"Total moisture content"},{"name":"范围","range":"(1,0 - 39,0) %"}],"search_zh":"全水分含量 重量法 范围 范围 PN-G-04611:2020-06","technique_zh":"重量法"},{"_id":"6a8369ecaf14b9c0e7b1dc25","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny, Solid fuels: hard coal","methodology":"Zawartość wilgoci całkowitej (z obliczeń), Total moisture content","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość wilgoci całkowitej (z obliczeń), Total moisture content","reference":"ASTM D 3302/D3302M-17 | PN-ISO 589:2006 metoda A1 | ISO 589:2008 metoda A1 | PN-G-04611:2020-06 | ASTM D 3302/D3302M-17 | PN-ISO 589:2006 A1 method | ISO 589:2008 A1 method | PN-G-04611:2020-06","norm_bases":["ASTM D 3302/D3302M-17","PN-ISO 589:2006 metoda A1","ISO 589:2008 metoda A1","PN-G-04611:2020-06","ASTM D 3302/D3302M-17","PN-ISO 589:2006 A1 method","ISO 589:2008 A1 method","PN-G-04611:2020-06"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny, Solid fuels: hard coal Zawartość wilgoci całkowitej (z obliczeń), Total moisture content ASTM D 3302/D3302M-17 | PN-ISO 589:2006 metoda A1 | ISO 589:2008 metoda A1 | PN-G-04611:2020-06 | ASTM D 3302/D3302M-17 | PN-ISO 589:2006 A1 method | ISO 589:2008 A1 method | PN-G-04611:2020-06 Paliwa stale: wegiel kamienny, Solid fuels: hard coal Zawartosc wilgoci calkowitej (z obliczen), Total moisture content ASTM D 3302/D3302M-17 | PN-ISO 589:2006 metoda A1 | ISO 589:2008 metoda A1 | PN-G-04611:2020-06 | ASTM D 3302/D3302M-17 | PN-ISO 589:2006 A1 method | ISO 589:2008 A1 method | PN-G-04611:2020-06","categories":["petro"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a8369ecaf14b9c0e7b1dc26","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny, Solid fuels: hard coal","methodology":"Zawartość wilgoci w próbce analitycznej","parameters":[{"name":"Zakres","range":"(0,2 - 16,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa","Gravimetric method"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (0,2 - 16,0) %\nMetoda wagowa","reference":"PN-G-04611:2020-06 | PN-ISO 11722:2009 | ISO 11722:2013 | ASTM D 3173-17a","norm_bases":["PN-G-04611:2020-06","PN-ISO 11722:2009","ISO 11722:2013","ASTM D 3173-17a"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny, Solid fuels: hard coal Zawartość wilgoci w próbce analitycznej\nZakres (0,2 - 16,0) %\nMetoda wagowa PN-G-04611:2020-06 | PN-ISO 11722:2009 | ISO 11722:2013 | ASTM D 3173-17a Paliwa stale: wegiel kamienny, Solid fuels: hard coal Zawartosc wilgoci w probce analitycznej\nZakres (0,2 - 16,0) %\nMetoda wagowa PN-G-04611:2020-06 | PN-ISO 11722:2009 | ISO 11722:2013 | ASTM D 3173-17a","categories":["petro"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Moisture content in the analytical sample","parameters_en":[{"name":"Range","range":"(0,2 - 16,0) %"}],"search_en":"Moisture content in the analytical sample Gravimetric method Range PN-G-04611:2020-06 | PN-ISO 11722:2009 | ISO 11722:2013 | ASTM D 3173-17a","technique_en":"Gravimetric method","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(0,2 - 16,0) %"}],"search_zh":"分析样品水分含量 重量法 范围 PN-G-04611:2020-06 | PN-ISO 11722:2009 | ISO 11722:2013 | ASTM D 3173-17a","technique_zh":"重量法"},{"_id":"6a8369ecaf14b9c0e7b1dc27","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny, Solid fuels: hard coal","methodology":"Zawartość wilgoci analitycznej","parameters":[{"name":"Zakres","range":"(0,1 - 15,0) %"},{"name":"Analytical moisture content"},{"name":"Range","range":"(0,1 - 15,0) %"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)","Thermogravimetric method (TGA)"],"computed":[],"activity":"Zawartość wilgoci analitycznej\nZakres:\nZakres (0,1 - 15,0) %\nAnalytical moisture content\nRange (0,1 - 15,0) %\nMetoda termograwimetryczna (TGA)","reference":"PN-ISO 11722:2009 | ISO 11722:2013","norm_bases":["PN-ISO 11722:2009","ISO 11722:2013"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny, Solid fuels: hard coal Zawartość wilgoci analitycznej\nZakres:\nZakres (0,1 - 15,0) %\nAnalytical moisture content\nRange (0,1 - 15,0) %\nMetoda termograwimetryczna (TGA) PN-ISO 11722:2009 | ISO 11722:2013 Paliwa stale: wegiel kamienny, Solid fuels: hard coal Zawartosc wilgoci analitycznej\nZakres:\nZakres (0,1 - 15,0) %\nAnalytical moisture content\nRange (0,1 - 15,0) %\nMetoda termograwimetryczna (TGA) PN-ISO 11722:2009 | ISO 11722:2013","categories":["petro"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Analytical moisture content","parameters_en":[{"name":"Range","range":"(0,1 - 15,0) %"},{"name":"Analytical moisture content"},{"name":"Range","range":"(0,1 - 15,0) %"}],"search_en":"Analytical moisture content Thermogravimetric method (TGA) Range Range PN-ISO 11722:2009 | ISO 11722:2013","technique_en":"Thermogravimetric method (TGA)","parameters_zh":[{"name":"范围","range":"(0,1 - 15,0) %"},{"name":"Analytical moisture content"},{"name":"范围","range":"(0,1 - 15,0) %"}],"search_zh":"分析水分含量 热重法（TGA） 范围 范围 PN-ISO 11722:2009 | ISO 11722:2013","technique_zh":"热重法（TGA）","methodology_zh":"分析水分含量"},{"_id":"6a8369ecaf14b9c0e7b1dc28","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny, Solid fuels: hard coal","methodology":"Zawartość wilgoci w próbce analitycznej","parameters":[{"name":"Zakres","range":"(0,20 - 16,00) %"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)","Thermogravimetric method (TGA)"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (0,20 - 16,00) %\nMetoda termograwimetryczna (TGA)","reference":"PN-G-04560:1998","norm_bases":["PN-G-04560:1998"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny, Solid fuels: hard coal Zawartość wilgoci w próbce analitycznej\nZakres (0,20 - 16,00) %\nMetoda termograwimetryczna (TGA) PN-G-04560:1998 Paliwa stale: wegiel kamienny, Solid fuels: hard coal Zawartosc wilgoci w probce analitycznej\nZakres (0,20 - 16,00) %\nMetoda termograwimetryczna (TGA) PN-G-04560:1998","categories":["petro"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Moisture content in the analytical sample","parameters_en":[{"name":"Range","range":"(0,20 - 16,00) %"}],"search_en":"Moisture content in the analytical sample Thermogravimetric method (TGA) Range PN-G-04560:1998","technique_en":"Thermogravimetric method (TGA)","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(0,20 - 16,00) %"}],"search_zh":"分析样品水分含量 热重法（TGA） 范围 PN-G-04560:1998","technique_zh":"热重法（TGA）"},{"_id":"6a8369ecaf14b9c0e7b1dc29","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny, Solid fuels: hard coal","methodology":"Zawartość popiołu","parameters":[{"name":"Zakres","range":"(0,70 - 69,10) %"},{"name":"Ash content"},{"name":"Range","range":"(0,70 - 69,10) %"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)","Thermogravimetric method (TGA)"],"computed":[],"activity":"Zawartość popiołu\nZakres:\nZakres (0,70 - 69,10) %\nAsh content\nRange (0,70 - 69,10) %\nMetoda termograwimetryczna (TGA)","reference":"PN-G-04560:1998","norm_bases":["PN-G-04560:1998"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny, Solid fuels: hard coal Zawartość popiołu\nZakres:\nZakres (0,70 - 69,10) %\nAsh content\nRange (0,70 - 69,10) %\nMetoda termograwimetryczna (TGA) PN-G-04560:1998 Paliwa stale: wegiel kamienny, Solid fuels: hard coal Zawartosc popiolu\nZakres:\nZakres (0,70 - 69,10) %\nAsh content\nRange (0,70 - 69,10) %\nMetoda termograwimetryczna (TGA) PN-G-04560:1998","categories":["petro"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ash content","parameters_en":[{"name":"Range","range":"(0,70 - 69,10) %"},{"name":"Ash content"},{"name":"Range","range":"(0,70 - 69,10) %"}],"search_en":"Ash content Thermogravimetric method (TGA) Range Ash content Range PN-G-04560:1998","technique_en":"Thermogravimetric method (TGA)","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(0,70 - 69,10) %"},{"name":"Ash content"},{"name":"范围","range":"(0,70 - 69,10) %"}],"search_zh":"灰分含量 热重法（TGA） 范围 范围 PN-G-04560:1998","technique_zh":"热重法（TGA）"},{"_id":"6a8369ecaf14b9c0e7b1dc2a","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny, Solid fuels: hard coal","methodology":"Zawartość popiołu","parameters":[{"name":"Zakres","range":"(0,7 - 69,1) %"},{"name":"Ash content"},{"name":"Range","range":"(0,7 - 69,1) %"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)","Thermogravimetric method (TGA)"],"computed":[],"activity":"Zawartość popiołu\nZakres:\nZakres (0,7 - 69,1) %\nAsh content\nRange (0,7 - 69,1) %\nMetoda termograwimetryczna (TGA)","reference":"PN-ISO 1171:2002 | ISO 1171:2024","norm_bases":["PN-ISO 1171:2002","ISO 1171:2024"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny, Solid fuels: hard coal Zawartość popiołu\nZakres:\nZakres (0,7 - 69,1) %\nAsh content\nRange (0,7 - 69,1) %\nMetoda termograwimetryczna (TGA) PN-ISO 1171:2002 | ISO 1171:2024 Paliwa stale: wegiel kamienny, Solid fuels: hard coal Zawartosc popiolu\nZakres:\nZakres (0,7 - 69,1) %\nAsh content\nRange (0,7 - 69,1) %\nMetoda termograwimetryczna (TGA) PN-ISO 1171:2002 | ISO 1171:2024","categories":["petro"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ash content","parameters_en":[{"name":"Range","range":"(0,7 - 69,1) %"},{"name":"Ash content"},{"name":"Range","range":"(0,7 - 69,1) %"}],"search_en":"Ash content Thermogravimetric method (TGA) Range Ash content Range PN-ISO 1171:2002 | ISO 1171:2024","technique_en":"Thermogravimetric method (TGA)","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(0,7 - 69,1) %"},{"name":"Ash content"},{"name":"范围","range":"(0,7 - 69,1) %"}],"search_zh":"灰分含量 热重法（TGA） 范围 范围 PN-ISO 1171:2002 | ISO 1171:2024","technique_zh":"热重法（TGA）"},{"_id":"6a8369ecaf14b9c0e7b1dc2b","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny, Solid fuels: hard coal","methodology":"Zawartość popiołu","parameters":[{"name":"Zakres","range":"(0,7 - 69,1) %"},{"name":"Ash content"},{"name":"Range","range":"(0,7 - 69,1) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa","Gravimetric method"],"computed":[],"activity":"Zawartość popiołu\nZakres:\nZakres (0,7 - 69,1) %\nAsh content\nRange (0,7 - 69,1) %\nMetoda wagowa","reference":"PN-80/G-04512+AZ1:2002 | PN-ISO 1171:2002 | ISO 1171:2024 | ASTM D 3174-12","norm_bases":["PN-80/G-04512+AZ1:2002","PN-ISO 1171:2002","ISO 1171:2024","ASTM D 3174-12"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny, Solid fuels: hard coal Zawartość popiołu\nZakres:\nZakres (0,7 - 69,1) %\nAsh content\nRange (0,7 - 69,1) %\nMetoda wagowa PN-80/G-04512+AZ1:2002 | PN-ISO 1171:2002 | ISO 1171:2024 | ASTM D 3174-12 Paliwa stale: wegiel kamienny, Solid fuels: hard coal Zawartosc popiolu\nZakres:\nZakres (0,7 - 69,1) %\nAsh content\nRange (0,7 - 69,1) %\nMetoda wagowa PN-80/G-04512+AZ1:2002 | PN-ISO 1171:2002 | ISO 1171:2024 | ASTM D 3174-12","categories":["petro"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ash content","parameters_en":[{"name":"Range","range":"(0,7 - 69,1) %"},{"name":"Ash content"},{"name":"Range","range":"(0,7 - 69,1) %"}],"search_en":"Ash content Gravimetric method Range Ash content Range PN-80/G-04512+AZ1:2002 | PN-ISO 1171:2002 | ISO 1171:2024 | ASTM D 3174-12","technique_en":"Gravimetric method","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(0,7 - 69,1) %"},{"name":"Ash content"},{"name":"范围","range":"(0,7 - 69,1) %"}],"search_zh":"灰分含量 重量法 范围 范围 PN-80/G-04512+AZ1:2002 | PN-ISO 1171:2002 | ISO 1171:2024 | ASTM D 3174-12","technique_zh":"重量法"},{"_id":"6a8369ecaf14b9c0e7b1dc2c","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny, Solid fuels: hard coal","methodology":"Zawartość części lotnych","parameters":[{"name":"Zakres","range":"(1,00 - 43,0) %"},{"name":"Volatile matter content"},{"name":"Range","range":"(1,00 - 43,00) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa","Gravimetric method"],"computed":[],"activity":"Zawartość części lotnych\nZakres:\nZakres (1,00 - 43,0) %\nVolatile matter content\nRange (1,00 - 43,00) %\nMetoda wagowa","reference":"PN-G-04516:1998 | ISO 562:2024 | ASTM D 3175-18","norm_bases":["PN-G-04516:1998","ISO 562:2024","ASTM D 3175-18"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny, Solid fuels: hard coal Zawartość części lotnych\nZakres:\nZakres (1,00 - 43,0) %\nVolatile matter content\nRange (1,00 - 43,00) %\nMetoda wagowa PN-G-04516:1998 | ISO 562:2024 | ASTM D 3175-18 Paliwa stale: wegiel kamienny, Solid fuels: hard coal Zawartosc czesci lotnych\nZakres:\nZakres (1,00 - 43,0) %\nVolatile matter content\nRange (1,00 - 43,00) %\nMetoda wagowa PN-G-04516:1998 | ISO 562:2024 | ASTM D 3175-18","categories":["petro"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Volatile matter content","parameters_en":[{"name":"Range","range":"(1,00 - 43,0) %"},{"name":"Volatile matter content"},{"name":"Range","range":"(1,00 - 43,00) %"}],"search_en":"Volatile matter content Gravimetric method Range Range PN-G-04516:1998 | ISO 562:2024 | ASTM D 3175-18","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(1,00 - 43,0) %"},{"name":"Volatile matter content"},{"name":"范围","range":"(1,00 - 43,00) %"}],"search_zh":"挥发分含量 重量法 范围 范围 PN-G-04516:1998 | ISO 562:2024 | ASTM D 3175-18","technique_zh":"重量法","methodology_zh":"挥发分含量"},{"_id":"6a8369ecaf14b9c0e7b1dc2d","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny, Solid fuels: hard coal","methodology":"Ciepło spalania","parameters":[{"name":"Zakres","range":"(7000 - 34600) kJ/kg"},{"name":"Wartość opałowa (z obliczeń) Gross calorific value"},{"name":"Range","range":"(7000 - 34600) kJ/kg"}],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna","Calorimetric method"],"computed":[],"activity":"Ciepło spalania\nZakres:\nZakres (7000 - 34600) kJ/kg\nWartość opałowa (z obliczeń) Gross calorific value\nRange (7000 - 34600) kJ/kg\nMetoda kalorymetryczna","reference":"PN-81/G-04513 | PN-ISO 1928:2020-05 | ISO 1928:2025 | ASTM D 5865-13","norm_bases":["PN-81/G-04513","PN-ISO 1928:2020-05","ISO 1928:2025","ASTM D 5865-13"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny, Solid fuels: hard coal Ciepło spalania\nZakres:\nZakres (7000 - 34600) kJ/kg\nWartość opałowa (z obliczeń) Gross calorific value\nRange (7000 - 34600) kJ/kg\nMetoda kalorymetryczna PN-81/G-04513 | PN-ISO 1928:2020-05 | ISO 1928:2025 | ASTM D 5865-13 Paliwa stale: wegiel kamienny, Solid fuels: hard coal Cieplo spalania\nZakres:\nZakres (7000 - 34600) kJ/kg\nWartosc opalowa (z obliczen) Gross calorific value\nRange (7000 - 34600) kJ/kg\nMetoda kalorymetryczna PN-81/G-04513 | PN-ISO 1928:2020-05 | ISO 1928:2025 | ASTM D 5865-13","categories":["petro"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gross calorific value","parameters_en":[{"name":"Range","range":"(7000 - 34600) kJ/kg"},{"name":"Wartość opałowa (z obliczeń) Gross calorific value"},{"name":"Range","range":"(7000 - 34600) kJ/kg"}],"search_en":"Gross calorific value Calorimetric method Range Range PN-81/G-04513 | PN-ISO 1928:2020-05 | ISO 1928:2025 | ASTM D 5865-13","technique_en":"Calorimetric method","methodology_zh":"高位发热量","parameters_zh":[{"name":"范围","range":"(7000 - 34600) kJ/kg"},{"name":"Wartość opałowa (z obliczeń) Gross calorific value"},{"name":"范围","range":"(7000 - 34600) kJ/kg"}],"search_zh":"高位发热量 量热法 范围 范围 PN-81/G-04513 | PN-ISO 1928:2020-05 | ISO 1928:2025 | ASTM D 5865-13","technique_zh":"量热法"},{"_id":"6a8369ecaf14b9c0e7b1dc2e","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny, Solid fuels: hard coal","methodology":"Zawartość siarki całkowitej","parameters":[{"name":"Zakres","range":"(0,10 - 4,35) %"},{"name":"Total sulphur content"},{"name":"Range","range":"(0,10 - 4,35) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR","High-temperature combustion method with IR detection"],"computed":[],"activity":"Zawartość siarki całkowitej\nZakres:\nZakres (0,10 - 4,35) %\nTotal sulphur content\nRange (0,10 - 4,35) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04584:2001 | ASTM D 4239-14e2 | ISO 19579:2006","norm_bases":["PN-G-04584:2001","ASTM D 4239-14e2","ISO 19579:2006"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny, Solid fuels: hard coal Zawartość siarki całkowitej\nZakres:\nZakres (0,10 - 4,35) %\nTotal sulphur content\nRange (0,10 - 4,35) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04584:2001 | ASTM D 4239-14e2 | ISO 19579:2006 Paliwa stale: wegiel kamienny, Solid fuels: hard coal Zawartosc siarki calkowitej\nZakres:\nZakres (0,10 - 4,35) %\nTotal sulphur content\nRange (0,10 - 4,35) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04584:2001 | ASTM D 4239-14e2 | ISO 19579:2006","categories":["petro"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total sulfur content","parameters_en":[{"name":"Range","range":"(0,10 - 4,35) %"},{"name":"Total sulphur content"},{"name":"Range","range":"(0,10 - 4,35) %"}],"search_en":"Total sulfur content High-temperature combustion with IR detection Range Range PN-G-04584:2001 | ASTM D 4239-14e2 | ISO 19579:2006","technique_en":"High-temperature combustion with IR detection","methodology_zh":"全硫含量","parameters_zh":[{"name":"范围","range":"(0,10 - 4,35) %"},{"name":"Total sulphur content"},{"name":"范围","range":"(0,10 - 4,35) %"}],"search_zh":"全硫含量 高温燃烧红外检测法 范围 范围 PN-G-04584:2001 | ASTM D 4239-14e2 | ISO 19579:2006","technique_zh":"高温燃烧红外检测法"},{"_id":"6a8369ecaf14b9c0e7b1dc2f","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny, Solid fuels: hard coal","methodology":"Zawartość azotu","parameters":[{"name":"Zakres","range":"(0,03 - 2,20) %"},{"name":"Nitrogen content"},{"name":"Range","range":"(0,03 - 2,20) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją TC","techniques":["Metoda wysokotemperaturowego spalania z detekcją TC","High-temperature combustion method with TC detection"],"computed":[],"activity":"Zawartość azotu\nZakres:\nZakres (0,03 - 2,20) %\nNitrogen content\nRange (0,03 - 2,20) %\nMetoda wysokotemperaturowego spalania z detekcją TC","reference":"PN-G-04571:1998 | ISO 29541:2025","norm_bases":["PN-G-04571:1998","ISO 29541:2025"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny, Solid fuels: hard coal Zawartość azotu\nZakres:\nZakres (0,03 - 2,20) %\nNitrogen content\nRange (0,03 - 2,20) %\nMetoda wysokotemperaturowego spalania z detekcją TC PN-G-04571:1998 | ISO 29541:2025 Paliwa stale: wegiel kamienny, Solid fuels: hard coal Zawartosc azotu\nZakres:\nZakres (0,03 - 2,20) %\nNitrogen content\nRange (0,03 - 2,20) %\nMetoda wysokotemperaturowego spalania z detekcja TC PN-G-04571:1998 | ISO 29541:2025","categories":["petro"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrogen content","parameters_en":[{"name":"Range","range":"(0,03 - 2,20) %"},{"name":"Nitrogen content"},{"name":"Range","range":"(0,03 - 2,20) %"}],"search_en":"Nitrogen content High-temperature combustion with TC detection Range Range PN-G-04571:1998 | ISO 29541:2025","technique_en":"High-temperature combustion with TC detection","methodology_zh":"氮含量","parameters_zh":[{"name":"范围","range":"(0,03 - 2,20) %"},{"name":"Nitrogen content"},{"name":"范围","range":"(0,03 - 2,20) %"}],"search_zh":"氮含量 高温燃烧总碳检测法 范围 范围 PN-G-04571:1998 | ISO 29541:2025","technique_zh":"高温燃烧总碳检测法"},{"_id":"6a8369ecaf14b9c0e7b1dc30","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny, Solid fuels: hard coal","methodology":"Zawartość chloru","parameters":[{"name":"Zakres","range":"(0,003 - 0,740) %"},{"name":"Chlorine content"},{"name":"Range","range":"(0,003 - 0,740) %"}],"technique":"Metoda miareczkowania potencjometrycznego","techniques":["Metoda miareczkowania potencjometrycznego","Potentiometric titration method"],"computed":[],"activity":"Zawartość chloru\nZakres:\nZakres (0,003 - 0,740) %\nChlorine content\nRange (0,003 - 0,740) %\nMetoda miareczkowania potencjometrycznego","reference":"PN-ISO 587:2000 IPPS-24 wersja 02 z dnia 30.05.2022 r. | PN-ISO 587:2000 IPPS-24 version 02 of 30.05.2022","norm_bases":["PN-ISO 587:2000 IPPS-24 wersja 02 z dnia 30.05.2022 r.","PN-ISO 587:2000 IPPS-24 version 02 of 30.05.2022"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny, Solid fuels: hard coal Zawartość chloru\nZakres:\nZakres (0,003 - 0,740) %\nChlorine content\nRange (0,003 - 0,740) %\nMetoda miareczkowania potencjometrycznego PN-ISO 587:2000 IPPS-24 wersja 02 z dnia 30.05.2022 r. | PN-ISO 587:2000 IPPS-24 version 02 of 30.05.2022 Paliwa stale: wegiel kamienny, Solid fuels: hard coal Zawartosc chloru\nZakres:\nZakres (0,003 - 0,740) %\nChlorine content\nRange (0,003 - 0,740) %\nMetoda miareczkowania potencjometrycznego PN-ISO 587:2000 IPPS-24 wersja 02 z dnia 30.05.2022 r. | PN-ISO 587:2000 IPPS-24 version 02 of 30.05.2022","categories":["petro"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chlorine content","parameters_en":[{"name":"Range","range":"(0,003 - 0,740) %"},{"name":"Chlorine content"},{"name":"Range","range":"(0,003 - 0,740) %"}],"search_en":"Chlorine content Potentiometric titration method Range Range PN-ISO 587:2000 IPPS-24 wersja 02 z dnia 30.05.2022 r. | PN-ISO 587:2000 IPPS-24 version 02 of 30.05.2022","technique_en":"Potentiometric titration method","parameters_zh":[{"name":"范围","range":"(0,003 - 0,740) %"},{"name":"Chlorine content"},{"name":"范围","range":"(0,003 - 0,740) %"}],"search_zh":"氯含量 电位滴定法 范围 范围 PN-ISO 587:2000 IPPS-24 wersja 02 z dnia 30.05.2022 r. | PN-ISO 587:2000 IPPS-24 version 02 of 30.05.2022","technique_zh":"电位滴定法","methodology_zh":"氯含量"},{"_id":"6a8369ecaf14b9c0e7b1dc31","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny, Solid fuels: hard coal","methodology":"Zawartość fluoru","parameters":[{"name":"Zakres","range":"(46 - 1496) μg/g"},{"name":"Fluorine content"},{"name":"Range","range":"(46 - 1496) μg/g"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna","Potentiometric method"],"computed":[],"activity":"Zawartość fluoru\nZakres:\nZakres (46 - 1496) μg/g\nFluorine content\nRange (46 - 1496) μg/g\nMetoda potencjometryczna","reference":"PN-ISO 11724:2008 p. 7.5.3 IPPS-23 wersja 02 z dnia 30.05.2022 r. | PN-ISO 11724:2008 p. 7.5.3 IPPS-23 version 02 of 30.05.2022","norm_bases":["PN-ISO 11724:2008 p. 7.5.3 IPPS-23 wersja 02 z dnia 30.05.2022 r.","PN-ISO 11724:2008 p. 7.5.3 IPPS-23 version 02 of 30.05.2022"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny, Solid fuels: hard coal Zawartość fluoru\nZakres:\nZakres (46 - 1496) μg/g\nFluorine content\nRange (46 - 1496) μg/g\nMetoda potencjometryczna PN-ISO 11724:2008 p. 7.5.3 IPPS-23 wersja 02 z dnia 30.05.2022 r. | PN-ISO 11724:2008 p. 7.5.3 IPPS-23 version 02 of 30.05.2022 Paliwa stale: wegiel kamienny, Solid fuels: hard coal Zawartosc fluoru\nZakres:\nZakres (46 - 1496) μg/g\nFluorine content\nRange (46 - 1496) μg/g\nMetoda potencjometryczna PN-ISO 11724:2008 p. 7.5.3 IPPS-23 wersja 02 z dnia 30.05.2022 r. | PN-ISO 11724:2008 p. 7.5.3 IPPS-23 version 02 of 30.05.2022","categories":["petro"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fluorine content","parameters_en":[{"name":"Range","range":"(46 - 1496) μg/g"},{"name":"Fluorine content"},{"name":"Range","range":"(46 - 1496) μg/g"}],"search_en":"Fluorine content Potentiometric method Range Range PN-ISO 11724:2008 p. 7.5.3 IPPS-23 wersja 02 z dnia 30.05.2022 r. | PN-ISO 11724:2008 p. 7.5.3 IPPS-23 version 02 of 30.05.2022","technique_en":"Potentiometric method","parameters_zh":[{"name":"范围","range":"(46 - 1496) μg/g"},{"name":"Fluorine content"},{"name":"范围","range":"(46 - 1496) μg/g"}],"search_zh":"氟含量 电位法 范围 范围 PN-ISO 11724:2008 p. 7.5.3 IPPS-23 wersja 02 z dnia 30.05.2022 r. | PN-ISO 11724:2008 p. 7.5.3 IPPS-23 version 02 of 30.05.2022","technique_zh":"电位法","methodology_zh":"氟含量"},{"_id":"6a8369ecaf14b9c0e7b1dc32","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny, Solid fuels: hard coal","methodology":"Wskaźnik wolnego wydymania","parameters":[{"name":"Zakres","range":"0 - 9"},{"name":"Crucible swelling number"},{"name":"Range","range":"0 - 9"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna","Visual method"],"computed":[],"activity":"Wskaźnik wolnego wydymania\nZakres:\nZakres 0 - 9\nCrucible swelling number\nRange 0 - 9\nMetoda wizualna","reference":"PN-ISO 501:2007 | ISO 501:2025","norm_bases":["PN-ISO 501:2007","ISO 501:2025"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny, Solid fuels: hard coal Wskaźnik wolnego wydymania\nZakres:\nZakres 0 - 9\nCrucible swelling number\nRange 0 - 9\nMetoda wizualna PN-ISO 501:2007 | ISO 501:2025 Paliwa stale: wegiel kamienny, Solid fuels: hard coal Wskaznik wolnego wydymania\nZakres:\nZakres 0 - 9\nCrucible swelling number\nRange 0 - 9\nMetoda wizualna PN-ISO 501:2007 | ISO 501:2025","categories":["petro"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free swelling index","parameters_en":[{"name":"Range","range":"0 - 9"},{"name":"Crucible swelling number"},{"name":"Range","range":"0 - 9"}],"search_en":"Free swelling index Visual method Range Range PN-ISO 501:2007 | ISO 501:2025","technique_en":"Visual method","parameters_zh":[{"name":"范围","range":"0 - 9"},{"name":"Crucible swelling number"},{"name":"范围","range":"0 - 9"}],"search_zh":"目视法 范围 范围 PN-ISO 501:2007 | ISO 501:2025","technique_zh":"目视法"},{"_id":"6a8369ecaf14b9c0e7b1dc33","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny, Solid fuels: hard coal","methodology":"Zdolność spiekania","parameters":[{"name":"Zakres","range":"0 - 90"},{"name":"Caking power"},{"name":"Range","range":"0 - 90"}],"technique":"Metoda Rogi","techniques":["Metoda Rogi","Roga method"],"computed":[],"activity":"Zdolność spiekania\nZakres:\nZakres 0 - 90\nCaking power\nRange 0 - 90\nMetoda Rogi","reference":"PN-G-04508:2020-05","norm_bases":["PN-G-04508:2020-05"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny, Solid fuels: hard coal Zdolność spiekania\nZakres:\nZakres 0 - 90\nCaking power\nRange 0 - 90\nMetoda Rogi PN-G-04508:2020-05 Paliwa stale: wegiel kamienny, Solid fuels: hard coal Zdolnosc spiekania\nZakres:\nZakres 0 - 90\nCaking power\nRange 0 - 90\nMetoda Rogi PN-G-04508:2020-05","categories":["petro"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Caking ability","parameters_en":[{"name":"Range","range":"0 - 90"},{"name":"Caking power"},{"name":"Range","range":"0 - 90"}],"search_en":"Caking ability Roga method Range Range PN-G-04508:2020-05","technique_en":"Roga method","parameters_zh":[{"name":"范围","range":"0 - 90"},{"name":"Caking power"},{"name":"范围","range":"0 - 90"}],"search_zh":"黏结性 罗加法（Roga） 范围 范围 PN-G-04508:2020-05","methodology_zh":"黏结性","technique_zh":"罗加法（Roga）"},{"_id":"6a8369ecaf14b9c0e7b1dc34","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny, Solid fuels: hard coal","methodology":"Wskaźnik fixed carbon (z obliczeń), Fixed carbon indices","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik fixed carbon (z obliczeń), Fixed carbon indices","reference":"PN-G-04516:1998 | ISO 17246:2024","norm_bases":["PN-G-04516:1998","ISO 17246:2024"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny, Solid fuels: hard coal Wskaźnik fixed carbon (z obliczeń), Fixed carbon indices PN-G-04516:1998 | ISO 17246:2024 Paliwa stale: wegiel kamienny, Solid fuels: hard coal Wskaznik fixed carbon (z obliczen), Fixed carbon indices PN-G-04516:1998 | ISO 17246:2024","categories":["petro"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a8369ecaf14b9c0e7b1dc35","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny, Solid fuels: hard coal","methodology":"Wskaźnik podatności przemiałowej","parameters":[{"name":"Zakres","range":"33 - 109"},{"name":"Hardgrove grindability index"}],"technique":"Metoda Hardgrove’a","techniques":["Metoda Hardgrove’a","Hardgrove method"],"computed":[],"activity":"Wskaźnik podatności przemiałowej\nZakres:\nZakres 33 - 109\nHardgrove grindability index\nMetoda Hardgrove’a","reference":"PN-ISO 5074:2002","norm_bases":["PN-ISO 5074:2002"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny, Solid fuels: hard coal Wskaźnik podatności przemiałowej\nZakres:\nZakres 33 - 109\nHardgrove grindability index\nMetoda Hardgrove’a PN-ISO 5074:2002 Paliwa stale: wegiel kamienny, Solid fuels: hard coal Wskaznik podatnosci przemialowej\nZakres:\nZakres 33 - 109\nHardgrove grindability index\nMetoda Hardgrove’a PN-ISO 5074:2002","categories":["petro"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Grindability index","parameters_en":[{"name":"Range","range":"33 - 109"},{"name":"Hardgrove grindability index"}],"search_en":"Grindability index Hardgrove method Range PN-ISO 5074:2002","technique_en":"Hardgrove method","parameters_zh":[{"name":"范围","range":"33 - 109"},{"name":"Hardgrove grindability index"}],"search_zh":"范围 PN-ISO 5074:2002"},{"_id":"6a8369ecaf14b9c0e7b1dc36","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: koks z węgla kamiennego, Solid fuels:","methodology":"Zawartość wilgoci całkowitej","parameters":[{"name":"Zakres","range":"(0,1 - 18,5) %"},{"name":"Total moisture content"},{"name":"Range","range":"(0,1 - 18,5) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa","Gravimetric method"],"computed":[],"activity":"Zawartość wilgoci całkowitej\nZakres:\nZakres (0,1 - 18,5) %\nTotal moisture content\nRange (0,1 - 18,5) %\nMetoda wagowa","reference":"PN-G-04611:2020-06 | PN-ISO 579:2002 | ISO 579:2013","norm_bases":["PN-G-04611:2020-06","PN-ISO 579:2002","ISO 579:2013"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: koks z węgla kamiennego, Solid fuels: Zawartość wilgoci całkowitej\nZakres:\nZakres (0,1 - 18,5) %\nTotal moisture content\nRange (0,1 - 18,5) %\nMetoda wagowa PN-G-04611:2020-06 | PN-ISO 579:2002 | ISO 579:2013 Paliwa stale: koks z wegla kamiennego, Solid fuels: Zawartosc wilgoci calkowitej\nZakres:\nZakres (0,1 - 18,5) %\nTotal moisture content\nRange (0,1 - 18,5) %\nMetoda wagowa PN-G-04611:2020-06 | PN-ISO 579:2002 | ISO 579:2013","categories":["petro"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total moisture content","parameters_en":[{"name":"Range","range":"(0,1 - 18,5) %"},{"name":"Total moisture content"},{"name":"Range","range":"(0,1 - 18,5) %"}],"search_en":"Total moisture content Gravimetric method Range Range PN-G-04611:2020-06 | PN-ISO 579:2002 | ISO 579:2013","technique_en":"Gravimetric method","methodology_zh":"全水分含量","parameters_zh":[{"name":"范围","range":"(0,1 - 18,5) %"},{"name":"Total moisture content"},{"name":"范围","range":"(0,1 - 18,5) %"}],"search_zh":"全水分含量 重量法 范围 范围 PN-G-04611:2020-06 | PN-ISO 579:2002 | ISO 579:2013","technique_zh":"重量法"},{"_id":"6a8369ecaf14b9c0e7b1dc37","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: koks z węgla kamiennego, Solid fuels:","methodology":"Zawartość wilgoci w próbce analitycznej","parameters":[{"name":"Zakres","range":"(0,1 - 2,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa","Gravimetric method"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (0,1 - 2,0) %\nMetoda wagowa","reference":"PN-G-04611:2020-06 | PN-ISO 687:2005 | ISO 687:2024 | ASTM D 3173-17a","norm_bases":["PN-G-04611:2020-06","PN-ISO 687:2005","ISO 687:2024","ASTM D 3173-17a"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: koks z węgla kamiennego, Solid fuels: Zawartość wilgoci w próbce analitycznej\nZakres (0,1 - 2,0) %\nMetoda wagowa PN-G-04611:2020-06 | PN-ISO 687:2005 | ISO 687:2024 | ASTM D 3173-17a Paliwa stale: koks z wegla kamiennego, Solid fuels: Zawartosc wilgoci w probce analitycznej\nZakres (0,1 - 2,0) %\nMetoda wagowa PN-G-04611:2020-06 | PN-ISO 687:2005 | ISO 687:2024 | ASTM D 3173-17a","categories":["petro"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Moisture content in the analytical sample","parameters_en":[{"name":"Range","range":"(0,1 - 2,0) %"}],"search_en":"Moisture content in the analytical sample Gravimetric method Range PN-G-04611:2020-06 | PN-ISO 687:2005 | ISO 687:2024 | ASTM D 3173-17a","technique_en":"Gravimetric method","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(0,1 - 2,0) %"}],"search_zh":"分析样品水分含量 重量法 范围 PN-G-04611:2020-06 | PN-ISO 687:2005 | ISO 687:2024 | ASTM D 3173-17a","technique_zh":"重量法"},{"_id":"6a8369ecaf14b9c0e7b1dc38","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: koks z węgla kamiennego, Solid fuels:","methodology":"Zawartość popiołu","parameters":[{"name":"Zakres","range":"(1,4 - 18,0) %"},{"name":"Ash content"},{"name":"Range","range":"(1,4 - 18,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa","Gravimetric method"],"computed":[],"activity":"Zawartość popiołu\nZakres:\nZakres (1,4 - 18,0) %\nAsh content\nRange (1,4 - 18,0) %\nMetoda wagowa","reference":"PN-80/G-04512+AZ1:2002 | PN-ISO 1171:2002 | ISO 1171:2024 | ASTM D 3174-12","norm_bases":["PN-80/G-04512+AZ1:2002","PN-ISO 1171:2002","ISO 1171:2024","ASTM D 3174-12"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: koks z węgla kamiennego, Solid fuels: Zawartość popiołu\nZakres:\nZakres (1,4 - 18,0) %\nAsh content\nRange (1,4 - 18,0) %\nMetoda wagowa PN-80/G-04512+AZ1:2002 | PN-ISO 1171:2002 | ISO 1171:2024 | ASTM D 3174-12 Paliwa stale: koks z wegla kamiennego, Solid fuels: Zawartosc popiolu\nZakres:\nZakres (1,4 - 18,0) %\nAsh content\nRange (1,4 - 18,0) %\nMetoda wagowa PN-80/G-04512+AZ1:2002 | PN-ISO 1171:2002 | ISO 1171:2024 | ASTM D 3174-12","categories":["petro"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ash content","parameters_en":[{"name":"Range","range":"(1,4 - 18,0) %"},{"name":"Ash content"},{"name":"Range","range":"(1,4 - 18,0) %"}],"search_en":"Ash content Gravimetric method Range Ash content Range PN-80/G-04512+AZ1:2002 | PN-ISO 1171:2002 | ISO 1171:2024 | ASTM D 3174-12","technique_en":"Gravimetric method","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(1,4 - 18,0) %"},{"name":"Ash content"},{"name":"范围","range":"(1,4 - 18,0) %"}],"search_zh":"灰分含量 重量法 范围 范围 PN-80/G-04512+AZ1:2002 | PN-ISO 1171:2002 | ISO 1171:2024 | ASTM D 3174-12","technique_zh":"重量法"},{"_id":"6a8369ecaf14b9c0e7b1dc39","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: koks z węgla kamiennego, Solid fuels:","methodology":"Zawartość części lotnych","parameters":[{"name":"Zakres","range":"(0,10 – 5,20) %"},{"name":"Volatile matter content"},{"name":"Range","range":"(0,10 - 5,20) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa","Gravimetric method"],"computed":[],"activity":"Zawartość części lotnych\nZakres:\nZakres (0,10 – 5,20) %\nVolatile matter content\nRange (0,10 - 5,20) %\nMetoda wagowa","reference":"PN-G-04516:1998 | ISO 562:2024 | ASTM D 3175-18","norm_bases":["PN-G-04516:1998","ISO 562:2024","ASTM D 3175-18"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: koks z węgla kamiennego, Solid fuels: Zawartość części lotnych\nZakres:\nZakres (0,10 – 5,20) %\nVolatile matter content\nRange (0,10 - 5,20) %\nMetoda wagowa PN-G-04516:1998 | ISO 562:2024 | ASTM D 3175-18 Paliwa stale: koks z wegla kamiennego, Solid fuels: Zawartosc czesci lotnych\nZakres:\nZakres (0,10 – 5,20) %\nVolatile matter content\nRange (0,10 - 5,20) %\nMetoda wagowa PN-G-04516:1998 | ISO 562:2024 | ASTM D 3175-18","categories":["petro"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Volatile matter content","parameters_en":[{"name":"Range","range":"(0,10 – 5,20) %"},{"name":"Volatile matter content"},{"name":"Range","range":"(0,10 - 5,20) %"}],"search_en":"Volatile matter content Gravimetric method Range Range PN-G-04516:1998 | ISO 562:2024 | ASTM D 3175-18","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(0,10 – 5,20) %"},{"name":"Volatile matter content"},{"name":"范围","range":"(0,10 - 5,20) %"}],"search_zh":"挥发分含量 重量法 范围 范围 PN-G-04516:1998 | ISO 562:2024 | ASTM D 3175-18","technique_zh":"重量法","methodology_zh":"挥发分含量"},{"_id":"6a8369ecaf14b9c0e7b1dc3a","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: koks z węgla kamiennego, Solid fuels:","methodology":"Ciepło spalania","parameters":[{"name":"Zakres","range":"(22000 - 34650) kJ/kg"},{"name":"Wartość opałowa (z obliczeń) Gross calorific value"},{"name":"Range","range":"(22000 - 34650) kJ/kg"}],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna","Calorimetric method"],"computed":[],"activity":"Ciepło spalania\nZakres:\nZakres (22000 - 34650) kJ/kg\nWartość opałowa (z obliczeń) Gross calorific value\nRange (22000 - 34650) kJ/kg\nMetoda kalorymetryczna","reference":"PN-81/G-04513 | PN-ISO 1928:2020-05 | ISO 1928:2025 | ASTM D 5865-13","norm_bases":["PN-81/G-04513","PN-ISO 1928:2020-05","ISO 1928:2025","ASTM D 5865-13"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: koks z węgla kamiennego, Solid fuels: Ciepło spalania\nZakres:\nZakres (22000 - 34650) kJ/kg\nWartość opałowa (z obliczeń) Gross calorific value\nRange (22000 - 34650) kJ/kg\nMetoda kalorymetryczna PN-81/G-04513 | PN-ISO 1928:2020-05 | ISO 1928:2025 | ASTM D 5865-13 Paliwa stale: koks z wegla kamiennego, Solid fuels: Cieplo spalania\nZakres:\nZakres (22000 - 34650) kJ/kg\nWartosc opalowa (z obliczen) Gross calorific value\nRange (22000 - 34650) kJ/kg\nMetoda kalorymetryczna PN-81/G-04513 | PN-ISO 1928:2020-05 | ISO 1928:2025 | ASTM D 5865-13","categories":["petro"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gross calorific value","parameters_en":[{"name":"Range","range":"(22000 - 34650) kJ/kg"},{"name":"Wartość opałowa (z obliczeń) Gross calorific value"},{"name":"Range","range":"(22000 - 34650) kJ/kg"}],"search_en":"Gross calorific value Calorimetric method Range Range PN-81/G-04513 | PN-ISO 1928:2020-05 | ISO 1928:2025 | ASTM D 5865-13","technique_en":"Calorimetric method","methodology_zh":"高位发热量","parameters_zh":[{"name":"范围","range":"(22000 - 34650) kJ/kg"},{"name":"Wartość opałowa (z obliczeń) Gross calorific value"},{"name":"范围","range":"(22000 - 34650) kJ/kg"}],"search_zh":"高位发热量 量热法 范围 范围 PN-81/G-04513 | PN-ISO 1928:2020-05 | ISO 1928:2025 | ASTM D 5865-13","technique_zh":"量热法"},{"_id":"6a8369ecaf14b9c0e7b1dc3b","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: koks z węgla kamiennego, Solid fuels:","methodology":"Zawartość siarki całkowitej","parameters":[{"name":"Zakres","range":"(0,20 - 1,24) %"},{"name":"Total sulphur content"},{"name":"Range","range":"(0,20 - 1,24) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR","High-temperature combustion method with IR detection"],"computed":[],"activity":"Zawartość siarki całkowitej\nZakres:\nZakres (0,20 - 1,24) %\nTotal sulphur content\nRange (0,20 - 1,24) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04584:2001 | ASTM D 4239-14e2 | ISO 19579:2006","norm_bases":["PN-G-04584:2001","ASTM D 4239-14e2","ISO 19579:2006"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: koks z węgla kamiennego, Solid fuels: Zawartość siarki całkowitej\nZakres:\nZakres (0,20 - 1,24) %\nTotal sulphur content\nRange (0,20 - 1,24) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04584:2001 | ASTM D 4239-14e2 | ISO 19579:2006 Paliwa stale: koks z wegla kamiennego, Solid fuels: Zawartosc siarki calkowitej\nZakres:\nZakres (0,20 - 1,24) %\nTotal sulphur content\nRange (0,20 - 1,24) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04584:2001 | ASTM D 4239-14e2 | ISO 19579:2006","categories":["petro"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total sulfur content","parameters_en":[{"name":"Range","range":"(0,20 - 1,24) %"},{"name":"Total sulphur content"},{"name":"Range","range":"(0,20 - 1,24) %"}],"search_en":"Total sulfur content High-temperature combustion with IR detection Range Range PN-G-04584:2001 | ASTM D 4239-14e2 | ISO 19579:2006","technique_en":"High-temperature combustion with IR detection","methodology_zh":"全硫含量","parameters_zh":[{"name":"范围","range":"(0,20 - 1,24) %"},{"name":"Total sulphur content"},{"name":"范围","range":"(0,20 - 1,24) %"}],"search_zh":"全硫含量 高温燃烧红外检测法 范围 范围 PN-G-04584:2001 | ASTM D 4239-14e2 | ISO 19579:2006","technique_zh":"高温燃烧红外检测法"},{"_id":"6a8369ecaf14b9c0e7b1dc3c","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: koks z węgla kamiennego, Solid fuels:","methodology":"Zawartość azotu","parameters":[{"name":"Zakres","range":"(0,20 - 2,00) %"},{"name":"Nitrogen content"},{"name":"Range","range":"(0,20 - 2,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją TC","techniques":["Metoda wysokotemperaturowego spalania z detekcją TC","High-temperature combustion method with TC detection"],"computed":[],"activity":"Zawartość azotu\nZakres:\nZakres (0,20 - 2,00) %\nNitrogen content\nRange (0,20 - 2,00) %\nMetoda wysokotemperaturowego spalania z detekcją TC","reference":"PN-G-04571:1998 | ISO 29541:2025","norm_bases":["PN-G-04571:1998","ISO 29541:2025"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: koks z węgla kamiennego, Solid fuels: Zawartość azotu\nZakres:\nZakres (0,20 - 2,00) %\nNitrogen content\nRange (0,20 - 2,00) %\nMetoda wysokotemperaturowego spalania z detekcją TC PN-G-04571:1998 | ISO 29541:2025 Paliwa stale: koks z wegla kamiennego, Solid fuels: Zawartosc azotu\nZakres:\nZakres (0,20 - 2,00) %\nNitrogen content\nRange (0,20 - 2,00) %\nMetoda wysokotemperaturowego spalania z detekcja TC PN-G-04571:1998 | ISO 29541:2025","categories":["petro"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrogen content","parameters_en":[{"name":"Range","range":"(0,20 - 2,00) %"},{"name":"Nitrogen content"},{"name":"Range","range":"(0,20 - 2,00) %"}],"search_en":"Nitrogen content High-temperature combustion with TC detection Range Range PN-G-04571:1998 | ISO 29541:2025","technique_en":"High-temperature combustion with TC detection","methodology_zh":"氮含量","parameters_zh":[{"name":"范围","range":"(0,20 - 2,00) %"},{"name":"Nitrogen content"},{"name":"范围","range":"(0,20 - 2,00) %"}],"search_zh":"氮含量 高温燃烧总碳检测法 范围 范围 PN-G-04571:1998 | ISO 29541:2025","technique_zh":"高温燃烧总碳检测法"},{"_id":"6a8369ecaf14b9c0e7b1dc3d","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: koks z węgla kamiennego, Solid fuels:","methodology":"Zawartość chloru","parameters":[{"name":"Zakres","range":"(0,003 - 0,163) %"},{"name":"Chlorine content"},{"name":"Range","range":"(0,003 - 0,163) %"}],"technique":"Metoda miareczkowania potencjometrycznego","techniques":["Metoda miareczkowania potencjometrycznego","Potentiometric titration method"],"computed":[],"activity":"Zawartość chloru\nZakres:\nZakres (0,003 - 0,163) %\nChlorine content\nRange (0,003 - 0,163) %\nMetoda miareczkowania potencjometrycznego","reference":"PN-ISO 587:2000 IPPS-24 wersja 02 z dnia 30.05.2022 r. | PN-ISO 587:2000 IPPS-24 version 02 of 30.05.2022","norm_bases":["PN-ISO 587:2000 IPPS-24 wersja 02 z dnia 30.05.2022 r.","PN-ISO 587:2000 IPPS-24 version 02 of 30.05.2022"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: koks z węgla kamiennego, Solid fuels: Zawartość chloru\nZakres:\nZakres (0,003 - 0,163) %\nChlorine content\nRange (0,003 - 0,163) %\nMetoda miareczkowania potencjometrycznego PN-ISO 587:2000 IPPS-24 wersja 02 z dnia 30.05.2022 r. | PN-ISO 587:2000 IPPS-24 version 02 of 30.05.2022 Paliwa stale: koks z wegla kamiennego, Solid fuels: Zawartosc chloru\nZakres:\nZakres (0,003 - 0,163) %\nChlorine content\nRange (0,003 - 0,163) %\nMetoda miareczkowania potencjometrycznego PN-ISO 587:2000 IPPS-24 wersja 02 z dnia 30.05.2022 r. | PN-ISO 587:2000 IPPS-24 version 02 of 30.05.2022","categories":["petro"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chlorine content","parameters_en":[{"name":"Range","range":"(0,003 - 0,163) %"},{"name":"Chlorine content"},{"name":"Range","range":"(0,003 - 0,163) %"}],"search_en":"Chlorine content Potentiometric titration method Range Range PN-ISO 587:2000 IPPS-24 wersja 02 z dnia 30.05.2022 r. | PN-ISO 587:2000 IPPS-24 version 02 of 30.05.2022","technique_en":"Potentiometric titration method","parameters_zh":[{"name":"范围","range":"(0,003 - 0,163) %"},{"name":"Chlorine content"},{"name":"范围","range":"(0,003 - 0,163) %"}],"search_zh":"氯含量 电位滴定法 范围 范围 PN-ISO 587:2000 IPPS-24 wersja 02 z dnia 30.05.2022 r. | PN-ISO 587:2000 IPPS-24 version 02 of 30.05.2022","technique_zh":"电位滴定法","methodology_zh":"氯含量"},{"_id":"6a8369ecaf14b9c0e7b1dc3e","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: koks z węgla kamiennego, Solid fuels:","methodology":"Wskaźnik fixed carbon (z obliczeń), Fixed carbon indices","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik fixed carbon (z obliczeń), Fixed carbon indices","reference":"PN-G-04516:1998 | ISO 17246:2024","norm_bases":["PN-G-04516:1998","ISO 17246:2024"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: koks z węgla kamiennego, Solid fuels: Wskaźnik fixed carbon (z obliczeń), Fixed carbon indices PN-G-04516:1998 | ISO 17246:2024 Paliwa stale: koks z wegla kamiennego, Solid fuels: Wskaznik fixed carbon (z obliczen), Fixed carbon indices PN-G-04516:1998 | ISO 17246:2024","categories":["petro"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a8369ecaf14b9c0e7b1dc3f","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny, koks z węgla kamiennego, Solid fuels: hard coal","methodology":"Zawartość siarki popiołowej","parameters":[{"name":"Zakres","range":"(0,10 - 4,55) %"},{"name":"Ash sulphur content"},{"name":"Range","range":"(0,10 - 4,55) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR","High-temperature combustion method with IR detection"],"computed":[],"activity":"Zawartość siarki popiołowej\nZakres:\nZakres (0,10 - 4,55) %\nAsh sulphur content\nRange (0,10 - 4,55) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04584:2001","norm_bases":["PN-G-04584:2001"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny, koks z węgla kamiennego, Solid fuels: hard coal Zawartość siarki popiołowej\nZakres:\nZakres (0,10 - 4,55) %\nAsh sulphur content\nRange (0,10 - 4,55) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04584:2001 Paliwa stale: wegiel kamienny, koks z wegla kamiennego, Solid fuels: hard coal Zawartosc siarki popiolowej\nZakres:\nZakres (0,10 - 4,55) %\nAsh sulphur content\nRange (0,10 - 4,55) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04584:2001","categories":["petro"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ash sulfur content","parameters_en":[{"name":"Range","range":"(0,10 - 4,55) %"},{"name":"Ash sulphur content"},{"name":"Range","range":"(0,10 - 4,55) %"}],"search_en":"Ash sulfur content High-temperature combustion with IR detection Range Range PN-G-04584:2001","technique_en":"High-temperature combustion with IR detection","parameters_zh":[{"name":"范围","range":"(0,10 - 4,55) %"},{"name":"Ash sulphur content"},{"name":"范围","range":"(0,10 - 4,55) %"}],"search_zh":"灰分硫含量 高温燃烧红外检测法 范围 范围 PN-G-04584:2001","technique_zh":"高温燃烧红外检测法","methodology_zh":"灰分硫含量"},{"_id":"6a8369ecaf14b9c0e7b1dc40","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny, koks z węgla kamiennego, Solid fuels: hard coal","methodology":"Zawartość siarki palnej (z obliczeń), Combustible sulphur content","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość siarki palnej (z obliczeń), Combustible sulphur content","reference":"PN-G-04584:2001","norm_bases":["PN-G-04584:2001"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny, koks z węgla kamiennego, Solid fuels: hard coal Zawartość siarki palnej (z obliczeń), Combustible sulphur content PN-G-04584:2001 Paliwa stale: wegiel kamienny, koks z wegla kamiennego, Solid fuels: hard coal Zawartosc siarki palnej (z obliczen), Combustible sulphur content PN-G-04584:2001","categories":["petro"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a8369ecaf14b9c0e7b1dc41","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny, koks z węgla kamiennego, Solid fuels: hard coal","methodology":"Zawartość chloru","parameters":[{"name":"Zakres","range":"(0,006 - 0,712) %"},{"name":"Chlorine content"},{"name":"Range","range":"(0,006 - 0,712) %"}],"technique":"Metoda miareczkowania potencjometrycznego","techniques":["Metoda miareczkowania potencjometrycznego","Potentiometric titration method"],"computed":[],"activity":"Zawartość chloru\nZakres:\nZakres (0,006 - 0,712) %\nChlorine content\nRange (0,006 - 0,712) %\nMetoda miareczkowania potencjometrycznego","reference":"PN-G-04534:2024-01","norm_bases":["PN-G-04534:2024-01"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny, koks z węgla kamiennego, Solid fuels: hard coal Zawartość chloru\nZakres:\nZakres (0,006 - 0,712) %\nChlorine content\nRange (0,006 - 0,712) %\nMetoda miareczkowania potencjometrycznego PN-G-04534:2024-01 Paliwa stale: wegiel kamienny, koks z wegla kamiennego, Solid fuels: hard coal Zawartosc chloru\nZakres:\nZakres (0,006 - 0,712) %\nChlorine content\nRange (0,006 - 0,712) %\nMetoda miareczkowania potencjometrycznego PN-G-04534:2024-01","categories":["petro"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chlorine content","parameters_en":[{"name":"Range","range":"(0,006 - 0,712) %"},{"name":"Chlorine content"},{"name":"Range","range":"(0,006 - 0,712) %"}],"search_en":"Chlorine content Potentiometric titration method Range Range PN-G-04534:2024-01","technique_en":"Potentiometric titration method","parameters_zh":[{"name":"范围","range":"(0,006 - 0,712) %"},{"name":"Chlorine content"},{"name":"范围","range":"(0,006 - 0,712) %"}],"search_zh":"氯含量 电位滴定法 范围 范围 PN-G-04534:2024-01","technique_zh":"电位滴定法","methodology_zh":"氯含量"},{"_id":"6a8369ecaf14b9c0e7b1dc42","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny, koks z węgla kamiennego, Solid fuels: hard coal","methodology":"Zawartość wodoru","parameters":[{"name":"Zakres","range":"(0,10 - 6,00) %"},{"name":"Hydrogen content"},{"name":"Range","range":"(0,10 - 6,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR","High-temperature combustion method with IR detection"],"computed":[],"activity":"Zawartość wodoru\nZakres:\nZakres (0,10 - 6,00) %\nHydrogen content\nRange (0,10 - 6,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04571:1998 | ISO 29541:2025","norm_bases":["PN-G-04571:1998","ISO 29541:2025"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny, koks z węgla kamiennego, Solid fuels: hard coal Zawartość wodoru\nZakres:\nZakres (0,10 - 6,00) %\nHydrogen content\nRange (0,10 - 6,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04571:1998 | ISO 29541:2025 Paliwa stale: wegiel kamienny, koks z wegla kamiennego, Solid fuels: hard coal Zawartosc wodoru\nZakres:\nZakres (0,10 - 6,00) %\nHydrogen content\nRange (0,10 - 6,00) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04571:1998 | ISO 29541:2025","categories":["petro"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrogen content","parameters_en":[{"name":"Range","range":"(0,10 - 6,00) %"},{"name":"Hydrogen content"},{"name":"Range","range":"(0,10 - 6,00) %"}],"search_en":"Hydrogen content High-temperature combustion with IR detection Range Range PN-G-04571:1998 | ISO 29541:2025","technique_en":"High-temperature combustion with IR detection","parameters_zh":[{"name":"范围","range":"(0,10 - 6,00) %"},{"name":"Hydrogen content"},{"name":"范围","range":"(0,10 - 6,00) %"}],"search_zh":"氢含量 高温燃烧红外检测法 范围 范围 PN-G-04571:1998 | ISO 29541:2025","technique_zh":"高温燃烧红外检测法","methodology_zh":"氢含量"},{"_id":"6a8369ecaf14b9c0e7b1dc43","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny, koks z węgla kamiennego, Solid fuels: hard coal","methodology":"Zawartość węgla całkowitego","parameters":[{"name":"Zakres","range":"(17,3 - 96,0) %"},{"name":"Total carbon content"},{"name":"Range","range":"(17,3 - 96,0) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR","High-temperature combustion method with IR detection"],"computed":[],"activity":"Zawartość węgla całkowitego\nZakres:\nZakres (17,3 - 96,0) %\nTotal carbon content\nRange (17,3 - 96,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"ISO 29541:2025 | PN-G-04571:1998","norm_bases":["ISO 29541:2025","PN-G-04571:1998"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny, koks z węgla kamiennego, Solid fuels: hard coal Zawartość węgla całkowitego\nZakres:\nZakres (17,3 - 96,0) %\nTotal carbon content\nRange (17,3 - 96,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR ISO 29541:2025 | PN-G-04571:1998 Paliwa stale: wegiel kamienny, koks z wegla kamiennego, Solid fuels: hard coal Zawartosc wegla calkowitego\nZakres:\nZakres (17,3 - 96,0) %\nTotal carbon content\nRange (17,3 - 96,0) %\nMetoda wysokotemperaturowego spalania z detekcja IR ISO 29541:2025 | PN-G-04571:1998","categories":["petro"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total carbon content","parameters_en":[{"name":"Range","range":"(17,3 - 96,0) %"},{"name":"Total carbon content"},{"name":"Range","range":"(17,3 - 96,0) %"}],"search_en":"Total carbon content High-temperature combustion with IR detection Range Range ISO 29541:2025 | PN-G-04571:1998","technique_en":"High-temperature combustion with IR detection","methodology_zh":"总碳含量","parameters_zh":[{"name":"范围","range":"(17,3 - 96,0) %"},{"name":"Total carbon content"},{"name":"范围","range":"(17,3 - 96,0) %"}],"search_zh":"总碳含量 高温燃烧红外检测法 范围 范围 ISO 29541:2025 | PN-G-04571:1998","technique_zh":"高温燃烧红外检测法"},{"_id":"6a8369ecaf14b9c0e7b1dc44","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny, koks z węgla kamiennego, Solid fuels: hard coal","methodology":"Wskaźnik emisji (z obliczeń), Emission factor","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik emisji (z obliczeń), Emission factor","reference":"PB-PPS-01 wersja 01 z dnia 05.08.2020 r. | PB-PPS-01 version 01 of 05.08.2020","norm_bases":["PB-PPS-01 wersja 01 z dnia 05.08.2020 r.","PB-PPS-01 version 01 of 05.08.2020"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny, koks z węgla kamiennego, Solid fuels: hard coal Wskaźnik emisji (z obliczeń), Emission factor PB-PPS-01 wersja 01 z dnia 05.08.2020 r. | PB-PPS-01 version 01 of 05.08.2020 Paliwa stale: wegiel kamienny, koks z wegla kamiennego, Solid fuels: hard coal Wskaznik emisji (z obliczen), Emission factor PB-PPS-01 wersja 01 z dnia 05.08.2020 r. | PB-PPS-01 version 01 of 05.08.2020","categories":["environment","petro"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a8369ecaf14b9c0e7b1dc45","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny, koks z węgla kamiennego, Solid fuels: hard coal","methodology":"Zawartość tlenu (z obliczeń), Oxygen content","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość tlenu (z obliczeń), Oxygen content","reference":"PN-ISO 1928:2020-05","norm_bases":["PN-ISO 1928:2020-05"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny, koks z węgla kamiennego, Solid fuels: hard coal Zawartość tlenu (z obliczeń), Oxygen content PN-ISO 1928:2020-05 Paliwa stale: wegiel kamienny, koks z wegla kamiennego, Solid fuels: hard coal Zawartosc tlenu (z obliczen), Oxygen content PN-ISO 1928:2020-05","categories":["petro"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a8369ecaf14b9c0e7b1dc46","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: koks naftowy, Solid fuels: petroleum coke","methodology":"Wskaźnik podatności przemiałowej","parameters":[{"name":"Zakres","range":"24 - 106"},{"name":"Hardgrove grindability index"}],"technique":"Metoda Hardgrove’a","techniques":["Metoda Hardgrove’a","Hardgrove method"],"computed":[],"activity":"Wskaźnik podatności przemiałowej\nZakres:\nZakres 24 - 106\nHardgrove grindability index\nMetoda Hardgrove’a","reference":"PN-ISO 5074:2002","norm_bases":["PN-ISO 5074:2002"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: koks naftowy, Solid fuels: petroleum coke Wskaźnik podatności przemiałowej\nZakres:\nZakres 24 - 106\nHardgrove grindability index\nMetoda Hardgrove’a PN-ISO 5074:2002 Paliwa stale: koks naftowy, Solid fuels: petroleum coke Wskaznik podatnosci przemialowej\nZakres:\nZakres 24 - 106\nHardgrove grindability index\nMetoda Hardgrove’a PN-ISO 5074:2002","categories":["petro"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Grindability index","parameters_en":[{"name":"Range","range":"24 - 106"},{"name":"Hardgrove grindability index"}],"search_en":"Grindability index Hardgrove method Range PN-ISO 5074:2002","technique_en":"Hardgrove method","parameters_zh":[{"name":"范围","range":"24 - 106"},{"name":"Hardgrove grindability index"}],"search_zh":"范围 PN-ISO 5074:2002"},{"_id":"6a8369ecaf14b9c0e7b1dc47","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: koks naftowy, Solid fuels: petroleum coke","methodology":"Zawartość wilgoci całkowitej","parameters":[{"name":"Zakres","range":"(0,1 - 12,8) %"},{"name":"Total moisture content"},{"name":"Range","range":"(0,1 - 12,8) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa","Gravimetric method"],"computed":[],"activity":"Zawartość wilgoci całkowitej\nZakres:\nZakres (0,1 - 12,8) %\nTotal moisture content\nRange (0,1 - 12,8) %\nMetoda wagowa","reference":"PN-ISO 579:2002 | ISO 579:2013","norm_bases":["PN-ISO 579:2002","ISO 579:2013"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: koks naftowy, Solid fuels: petroleum coke Zawartość wilgoci całkowitej\nZakres:\nZakres (0,1 - 12,8) %\nTotal moisture content\nRange (0,1 - 12,8) %\nMetoda wagowa PN-ISO 579:2002 | ISO 579:2013 Paliwa stale: koks naftowy, Solid fuels: petroleum coke Zawartosc wilgoci calkowitej\nZakres:\nZakres (0,1 - 12,8) %\nTotal moisture content\nRange (0,1 - 12,8) %\nMetoda wagowa PN-ISO 579:2002 | ISO 579:2013","categories":["petro"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total moisture content","parameters_en":[{"name":"Range","range":"(0,1 - 12,8) %"},{"name":"Total moisture content"},{"name":"Range","range":"(0,1 - 12,8) %"}],"search_en":"Total moisture content Gravimetric method Range Range PN-ISO 579:2002 | ISO 579:2013","technique_en":"Gravimetric method","methodology_zh":"全水分含量","parameters_zh":[{"name":"范围","range":"(0,1 - 12,8) %"},{"name":"Total moisture content"},{"name":"范围","range":"(0,1 - 12,8) %"}],"search_zh":"全水分含量 重量法 范围 范围 PN-ISO 579:2002 | ISO 579:2013","technique_zh":"重量法"},{"_id":"6a8369ecaf14b9c0e7b1dc48","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: koks naftowy, Solid fuels: petroleum coke","methodology":"Zawartość wilgoci w próbce analitycznej","parameters":[{"name":"Zakres","range":"(0,1 - 2,4) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa","Gravimetric method"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (0,1 - 2,4) %\nMetoda wagowa","reference":"PN-ISO 687:2005 | ISO 687:2024","norm_bases":["PN-ISO 687:2005","ISO 687:2024"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: koks naftowy, Solid fuels: petroleum coke Zawartość wilgoci w próbce analitycznej\nZakres (0,1 - 2,4) %\nMetoda wagowa PN-ISO 687:2005 | ISO 687:2024 Paliwa stale: koks naftowy, Solid fuels: petroleum coke Zawartosc wilgoci w probce analitycznej\nZakres (0,1 - 2,4) %\nMetoda wagowa PN-ISO 687:2005 | ISO 687:2024","categories":["petro"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Moisture content in the analytical sample","parameters_en":[{"name":"Range","range":"(0,1 - 2,4) %"}],"search_en":"Moisture content in the analytical sample Gravimetric method Range PN-ISO 687:2005 | ISO 687:2024","technique_en":"Gravimetric method","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(0,1 - 2,4) %"}],"search_zh":"分析样品水分含量 重量法 范围 PN-ISO 687:2005 | ISO 687:2024","technique_zh":"重量法"},{"_id":"6a8369ecaf14b9c0e7b1dc49","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: koks naftowy, Solid fuels: petroleum coke","methodology":"Zawartość popiołu","parameters":[{"name":"Zakres","range":"(0,1 - 4,3) %"},{"name":"Ash content"},{"name":"Range","range":"(0,1 - 4,3) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa","Gravimetric method"],"computed":[],"activity":"Zawartość popiołu\nZakres:\nZakres (0,1 - 4,3) %\nAsh content\nRange (0,1 - 4,3) %\nMetoda wagowa","reference":"PN-ISO 1171:2002 | ISO 1171:2024","norm_bases":["PN-ISO 1171:2002","ISO 1171:2024"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: koks naftowy, Solid fuels: petroleum coke Zawartość popiołu\nZakres:\nZakres (0,1 - 4,3) %\nAsh content\nRange (0,1 - 4,3) %\nMetoda wagowa PN-ISO 1171:2002 | ISO 1171:2024 Paliwa stale: koks naftowy, Solid fuels: petroleum coke Zawartosc popiolu\nZakres:\nZakres (0,1 - 4,3) %\nAsh content\nRange (0,1 - 4,3) %\nMetoda wagowa PN-ISO 1171:2002 | ISO 1171:2024","categories":["petro"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ash content","parameters_en":[{"name":"Range","range":"(0,1 - 4,3) %"},{"name":"Ash content"},{"name":"Range","range":"(0,1 - 4,3) %"}],"search_en":"Ash content Gravimetric method Range Ash content Range PN-ISO 1171:2002 | ISO 1171:2024","technique_en":"Gravimetric method","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(0,1 - 4,3) %"},{"name":"Ash content"},{"name":"范围","range":"(0,1 - 4,3) %"}],"search_zh":"灰分含量 重量法 范围 范围 PN-ISO 1171:2002 | ISO 1171:2024","technique_zh":"重量法"},{"_id":"6a8369ecaf14b9c0e7b1dc4a","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: koks naftowy, Solid fuels: petroleum coke","methodology":"Zawartość części lotnych","parameters":[{"name":"Zakres","range":"(0,3 - 22,5) %"},{"name":"Volatile matter content"},{"name":"Range","range":"(0,3 - 22,5) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa","Gravimetric method"],"computed":[],"activity":"Zawartość części lotnych\nZakres:\nZakres (0,3 - 22,5) %\nVolatile matter content\nRange (0,3 - 22,5) %\nMetoda wagowa","reference":"ISO 562:2024","norm_bases":["ISO 562:2024"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: koks naftowy, Solid fuels: petroleum coke Zawartość części lotnych\nZakres:\nZakres (0,3 - 22,5) %\nVolatile matter content\nRange (0,3 - 22,5) %\nMetoda wagowa ISO 562:2024 Paliwa stale: koks naftowy, Solid fuels: petroleum coke Zawartosc czesci lotnych\nZakres:\nZakres (0,3 - 22,5) %\nVolatile matter content\nRange (0,3 - 22,5) %\nMetoda wagowa ISO 562:2024","categories":["petro"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Volatile matter content","parameters_en":[{"name":"Range","range":"(0,3 - 22,5) %"},{"name":"Volatile matter content"},{"name":"Range","range":"(0,3 - 22,5) %"}],"search_en":"Volatile matter content Gravimetric method Range Range ISO 562:2024","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(0,3 - 22,5) %"},{"name":"Volatile matter content"},{"name":"范围","range":"(0,3 - 22,5) %"}],"search_zh":"挥发分含量 重量法 范围 范围 ISO 562:2024","technique_zh":"重量法","methodology_zh":"挥发分含量"},{"_id":"6a8369ecaf14b9c0e7b1dc4b","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: koks naftowy, Solid fuels: petroleum coke","methodology":"Zawartość siarki całkowitej","parameters":[{"name":"Zakres","range":"(0,07 - 6,77) %"},{"name":"Total sulphur content"},{"name":"Range","range":"(0,07 - 6,77) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR","High-temperature combustion method with IR detection"],"computed":[],"activity":"Zawartość siarki całkowitej\nZakres:\nZakres (0,07 - 6,77) %\nTotal sulphur content\nRange (0,07 - 6,77) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"ISO 19579:2006","norm_bases":["ISO 19579:2006"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: koks naftowy, Solid fuels: petroleum coke Zawartość siarki całkowitej\nZakres:\nZakres (0,07 - 6,77) %\nTotal sulphur content\nRange (0,07 - 6,77) %\nMetoda wysokotemperaturowego spalania z detekcją IR ISO 19579:2006 Paliwa stale: koks naftowy, Solid fuels: petroleum coke Zawartosc siarki calkowitej\nZakres:\nZakres (0,07 - 6,77) %\nTotal sulphur content\nRange (0,07 - 6,77) %\nMetoda wysokotemperaturowego spalania z detekcja IR ISO 19579:2006","categories":["petro"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total sulfur content","parameters_en":[{"name":"Range","range":"(0,07 - 6,77) %"},{"name":"Total sulphur content"},{"name":"Range","range":"(0,07 - 6,77) %"}],"search_en":"Total sulfur content High-temperature combustion with IR detection Range Range ISO 19579:2006","technique_en":"High-temperature combustion with IR detection","methodology_zh":"全硫含量","parameters_zh":[{"name":"范围","range":"(0,07 - 6,77) %"},{"name":"Total sulphur content"},{"name":"范围","range":"(0,07 - 6,77) %"}],"search_zh":"全硫含量 高温燃烧红外检测法 范围 范围 ISO 19579:2006","technique_zh":"高温燃烧红外检测法"},{"_id":"6a8369ecaf14b9c0e7b1dc4c","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: koks naftowy, Solid fuels: petroleum coke","methodology":"Ciepło spalania","parameters":[{"name":"Zakres","range":"(30550 - 36545) kJ/kg"},{"name":"Wartość opałowa (z obliczeń) Gross calorific value"},{"name":"Range","range":"(30550 - 36545) kJ/kg"}],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna","Calorimetric method"],"computed":[],"activity":"Ciepło spalania\nZakres:\nZakres (30550 - 36545) kJ/kg\nWartość opałowa (z obliczeń) Gross calorific value\nRange (30550 - 36545) kJ/kg\nMetoda kalorymetryczna","reference":"PN-ISO 1928:2020-05 | ISO 1928:2025","norm_bases":["PN-ISO 1928:2020-05","ISO 1928:2025"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: koks naftowy, Solid fuels: petroleum coke Ciepło spalania\nZakres:\nZakres (30550 - 36545) kJ/kg\nWartość opałowa (z obliczeń) Gross calorific value\nRange (30550 - 36545) kJ/kg\nMetoda kalorymetryczna PN-ISO 1928:2020-05 | ISO 1928:2025 Paliwa stale: koks naftowy, Solid fuels: petroleum coke Cieplo spalania\nZakres:\nZakres (30550 - 36545) kJ/kg\nWartosc opalowa (z obliczen) Gross calorific value\nRange (30550 - 36545) kJ/kg\nMetoda kalorymetryczna PN-ISO 1928:2020-05 | ISO 1928:2025","categories":["petro"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gross calorific value","parameters_en":[{"name":"Range","range":"(30550 - 36545) kJ/kg"},{"name":"Wartość opałowa (z obliczeń) Gross calorific value"},{"name":"Range","range":"(30550 - 36545) kJ/kg"}],"search_en":"Gross calorific value Calorimetric method Range Range PN-ISO 1928:2020-05 | ISO 1928:2025","technique_en":"Calorimetric method","methodology_zh":"高位发热量","parameters_zh":[{"name":"范围","range":"(30550 - 36545) kJ/kg"},{"name":"Wartość opałowa (z obliczeń) Gross calorific value"},{"name":"范围","range":"(30550 - 36545) kJ/kg"}],"search_zh":"高位发热量 量热法 范围 范围 PN-ISO 1928:2020-05 | ISO 1928:2025","technique_zh":"量热法"},{"_id":"6a8369ecaf14b9c0e7b1dc4d","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: koks naftowy, Solid fuels: petroleum coke","methodology":"Zawartość wodoru całkowitego","parameters":[{"name":"Zakres","range":"(0,10 - 4,85) %"},{"name":"Hydrogen content"},{"name":"Range","range":"(0,10 - 4,85) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR","High-temperature combustion method with IR detection"],"computed":[],"activity":"Zawartość wodoru całkowitego\nZakres:\nZakres (0,10 - 4,85) %\nHydrogen content\nRange (0,10 - 4,85) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"ISO 29541:2025","norm_bases":["ISO 29541:2025"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: koks naftowy, Solid fuels: petroleum coke Zawartość wodoru całkowitego\nZakres:\nZakres (0,10 - 4,85) %\nHydrogen content\nRange (0,10 - 4,85) %\nMetoda wysokotemperaturowego spalania z detekcją IR ISO 29541:2025 Paliwa stale: koks naftowy, Solid fuels: petroleum coke Zawartosc wodoru calkowitego\nZakres:\nZakres (0,10 - 4,85) %\nHydrogen content\nRange (0,10 - 4,85) %\nMetoda wysokotemperaturowego spalania z detekcja IR ISO 29541:2025","categories":["petro"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total hydrogen content","parameters_en":[{"name":"Range","range":"(0,10 - 4,85) %"},{"name":"Hydrogen content"},{"name":"Range","range":"(0,10 - 4,85) %"}],"search_en":"Total hydrogen content High-temperature combustion with IR detection Range Range ISO 29541:2025","technique_en":"High-temperature combustion with IR detection","parameters_zh":[{"name":"范围","range":"(0,10 - 4,85) %"},{"name":"Hydrogen content"},{"name":"范围","range":"(0,10 - 4,85) %"}],"search_zh":"全氢含量 高温燃烧红外检测法 范围 范围 ISO 29541:2025","technique_zh":"高温燃烧红外检测法","methodology_zh":"全氢含量"},{"_id":"6a8369ecaf14b9c0e7b1dc4e","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: koks naftowy, Solid fuels: petroleum coke","methodology":"Zawartość węgla całkowitego","parameters":[{"name":"Zakres","range":"(83,9 - 99,2) %"},{"name":"Total carbon content"},{"name":"Range","range":"(83,9 - 99,2) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR","High-temperature combustion method with IR detection"],"computed":[],"activity":"Zawartość węgla całkowitego\nZakres:\nZakres (83,9 - 99,2) %\nTotal carbon content\nRange (83,9 - 99,2) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"ISO 29541:2025","norm_bases":["ISO 29541:2025"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: koks naftowy, Solid fuels: petroleum coke Zawartość węgla całkowitego\nZakres:\nZakres (83,9 - 99,2) %\nTotal carbon content\nRange (83,9 - 99,2) %\nMetoda wysokotemperaturowego spalania z detekcją IR ISO 29541:2025 Paliwa stale: koks naftowy, Solid fuels: petroleum coke Zawartosc wegla calkowitego\nZakres:\nZakres (83,9 - 99,2) %\nTotal carbon content\nRange (83,9 - 99,2) %\nMetoda wysokotemperaturowego spalania z detekcja IR ISO 29541:2025","categories":["petro"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total carbon content","parameters_en":[{"name":"Range","range":"(83,9 - 99,2) %"},{"name":"Total carbon content"},{"name":"Range","range":"(83,9 - 99,2) %"}],"search_en":"Total carbon content High-temperature combustion with IR detection Range Range ISO 29541:2025","technique_en":"High-temperature combustion with IR detection","methodology_zh":"总碳含量","parameters_zh":[{"name":"范围","range":"(83,9 - 99,2) %"},{"name":"Total carbon content"},{"name":"范围","range":"(83,9 - 99,2) %"}],"search_zh":"总碳含量 高温燃烧红外检测法 范围 范围 ISO 29541:2025","technique_zh":"高温燃烧红外检测法"},{"_id":"6a8369ecaf14b9c0e7b1dc4f","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: koks naftowy, Solid fuels: petroleum coke","methodology":"Zawartość azotu","parameters":[{"name":"Zakres","range":"(0,03 - 2,01) %"},{"name":"Nitrogen content"},{"name":"Range","range":"(0,03 - 2,01) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją TC","techniques":["Metoda wysokotemperaturowego spalania z detekcją TC","High-temperature combustion method with TC detection"],"computed":[],"activity":"Zawartość azotu\nZakres:\nZakres (0,03 - 2,01) %\nNitrogen content\nRange (0,03 - 2,01) %\nMetoda wysokotemperaturowego spalania z detekcją TC","reference":"ISO 29541:2025","norm_bases":["ISO 29541:2025"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: koks naftowy, Solid fuels: petroleum coke Zawartość azotu\nZakres:\nZakres (0,03 - 2,01) %\nNitrogen content\nRange (0,03 - 2,01) %\nMetoda wysokotemperaturowego spalania z detekcją TC ISO 29541:2025 Paliwa stale: koks naftowy, Solid fuels: petroleum coke Zawartosc azotu\nZakres:\nZakres (0,03 - 2,01) %\nNitrogen content\nRange (0,03 - 2,01) %\nMetoda wysokotemperaturowego spalania z detekcja TC ISO 29541:2025","categories":["petro"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrogen content","parameters_en":[{"name":"Range","range":"(0,03 - 2,01) %"},{"name":"Nitrogen content"},{"name":"Range","range":"(0,03 - 2,01) %"}],"search_en":"Nitrogen content High-temperature combustion with TC detection Range Range ISO 29541:2025","technique_en":"High-temperature combustion with TC detection","methodology_zh":"氮含量","parameters_zh":[{"name":"范围","range":"(0,03 - 2,01) %"},{"name":"Nitrogen content"},{"name":"范围","range":"(0,03 - 2,01) %"}],"search_zh":"氮含量 高温燃烧总碳检测法 范围 范围 ISO 29541:2025","technique_zh":"高温燃烧总碳检测法"},{"_id":"6a8369ecaf14b9c0e7b1dc50","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: koks naftowy, Solid fuels: petroleum coke","methodology":"Wskaźnik emisji (z obliczeń), Emission factor","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik emisji (z obliczeń), Emission factor","reference":"PB-PPS-01 wersja 01 z dnia 05.08.2020 r. | PB-PPS-01 version 01 of 05.08.2020","norm_bases":["PB-PPS-01 wersja 01 z dnia 05.08.2020 r.","PB-PPS-01 version 01 of 05.08.2020"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: koks naftowy, Solid fuels: petroleum coke Wskaźnik emisji (z obliczeń), Emission factor PB-PPS-01 wersja 01 z dnia 05.08.2020 r. | PB-PPS-01 version 01 of 05.08.2020 Paliwa stale: koks naftowy, Solid fuels: petroleum coke Wskaznik emisji (z obliczen), Emission factor PB-PPS-01 wersja 01 z dnia 05.08.2020 r. | PB-PPS-01 version 01 of 05.08.2020","categories":["petro","environment"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a8369ecaf14b9c0e7b1dc51","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: koks naftowy, Solid fuels: petroleum coke","methodology":"Wskaźnik fixed carbon (z obliczeń), Fixed carbon indices","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik fixed carbon (z obliczeń), Fixed carbon indices","reference":"ISO 17246:2024","norm_bases":["ISO 17246:2024"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: koks naftowy, Solid fuels: petroleum coke Wskaźnik fixed carbon (z obliczeń), Fixed carbon indices ISO 17246:2024 Paliwa stale: koks naftowy, Solid fuels: petroleum coke Wskaznik fixed carbon (z obliczen), Fixed carbon indices ISO 17246:2024","categories":["petro"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a8369ecaf14b9c0e7b1dc52","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: koks naftowy, Solid fuels: petroleum coke","methodology":"Zawartość tlenu (z obliczeń), Oxygen content","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość tlenu (z obliczeń), Oxygen content","reference":"PN-ISO 1928:2020-05","norm_bases":["PN-ISO 1928:2020-05"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: koks naftowy, Solid fuels: petroleum coke Zawartość tlenu (z obliczeń), Oxygen content PN-ISO 1928:2020-05 Paliwa stale: koks naftowy, Solid fuels: petroleum coke Zawartosc tlenu (z obliczen), Oxygen content PN-ISO 1928:2020-05","categories":["petro"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a8369ecaf14b9c0e7b1dc53","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: koks naftowy, Solid fuels: petroleum coke","methodology":"Zawartość chloru","parameters":[{"name":"Zakres","range":"(0,012 - 0,212) %"},{"name":"Chlorine content"},{"name":"Range","range":"(0,012 - 0,212) %"}],"technique":"Metoda miareczkowania potencjometrycznego","techniques":["Metoda miareczkowania potencjometrycznego","Potentiometric titration method"],"computed":[],"activity":"Zawartość chloru\nZakres:\nZakres (0,012 - 0,212) %\nChlorine content\nRange (0,012 - 0,212) %\nMetoda miareczkowania potencjometrycznego","reference":"PN-G-04534:2024-01","norm_bases":["PN-G-04534:2024-01"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: koks naftowy, Solid fuels: petroleum coke Zawartość chloru\nZakres:\nZakres (0,012 - 0,212) %\nChlorine content\nRange (0,012 - 0,212) %\nMetoda miareczkowania potencjometrycznego PN-G-04534:2024-01 Paliwa stale: koks naftowy, Solid fuels: petroleum coke Zawartosc chloru\nZakres:\nZakres (0,012 - 0,212) %\nChlorine content\nRange (0,012 - 0,212) %\nMetoda miareczkowania potencjometrycznego PN-G-04534:2024-01","categories":["petro"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chlorine content","parameters_en":[{"name":"Range","range":"(0,012 - 0,212) %"},{"name":"Chlorine content"},{"name":"Range","range":"(0,012 - 0,212) %"}],"search_en":"Chlorine content Potentiometric titration method Range Range PN-G-04534:2024-01","technique_en":"Potentiometric titration method","parameters_zh":[{"name":"范围","range":"(0,012 - 0,212) %"},{"name":"Chlorine content"},{"name":"范围","range":"(0,012 - 0,212) %"}],"search_zh":"氯含量 电位滴定法 范围 范围 PN-G-04534:2024-01","technique_zh":"电位滴定法","methodology_zh":"氯含量"},{"_id":"6a8369ecaf14b9c0e7b1dc54","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: koks naftowy, Solid fuels: petroleum coke","methodology":"Zawartość chloru","parameters":[{"name":"Zakres","range":"(0,006 - 0,205) %"},{"name":"Chlorine content"},{"name":"Range","range":"(0,006 - 0,205) %"}],"technique":"Metoda miareczkowania potencjometrycznego","techniques":["Metoda miareczkowania potencjometrycznego","Potentiometric titration method"],"computed":[],"activity":"Zawartość chloru\nZakres:\nZakres (0,006 - 0,205) %\nChlorine content\nRange (0,006 - 0,205) %\nMetoda miareczkowania potencjometrycznego","reference":"PN-ISO 587:2000 IPPS-27 wersja 01 z dnia 18.02.2026 r. | PN-ISO 587:2000 IPPS-27 version 01 of 18.02.2026","norm_bases":["PN-ISO 587:2000 IPPS-27 wersja 01 z dnia 18.02.2026 r.","PN-ISO 587:2000 IPPS-27 version 01 of 18.02.2026"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":"Kody odpadów podane według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów | Waste codes given according to the Regulation of the Minister of Climate on the waste catalogue","flexible":false,"search_text":"Paliwa stałe: koks naftowy, Solid fuels: petroleum coke Zawartość chloru\nZakres:\nZakres (0,006 - 0,205) %\nChlorine content\nRange (0,006 - 0,205) %\nMetoda miareczkowania potencjometrycznego PN-ISO 587:2000 IPPS-27 wersja 01 z dnia 18.02.2026 r. | PN-ISO 587:2000 IPPS-27 version 01 of 18.02.2026 Paliwa stale: koks naftowy, Solid fuels: petroleum coke Zawartosc chloru\nZakres:\nZakres (0,006 - 0,205) %\nChlorine content\nRange (0,006 - 0,205) %\nMetoda miareczkowania potencjometrycznego PN-ISO 587:2000 IPPS-27 wersja 01 z dnia 18.02.2026 r. | PN-ISO 587:2000 IPPS-27 version 01 of 18.02.2026","categories":["petro"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chlorine content","parameters_en":[{"name":"Range","range":"(0,006 - 0,205) %"},{"name":"Chlorine content"},{"name":"Range","range":"(0,006 - 0,205) %"}],"search_en":"Chlorine content Potentiometric titration method Range Range PN-ISO 587:2000 IPPS-27 wersja 01 z dnia 18.02.2026 r. | PN-ISO 587:2000 IPPS-27 version 01 of 18.02.2026","technique_en":"Potentiometric titration method","parameters_zh":[{"name":"范围","range":"(0,006 - 0,205) %"},{"name":"Chlorine content"},{"name":"范围","range":"(0,006 - 0,205) %"}],"search_zh":"氯含量 电位滴定法 范围 范围 PN-ISO 587:2000 IPPS-27 wersja 01 z dnia 18.02.2026 r. | PN-ISO 587:2000 IPPS-27 version 01 of 18.02.2026","technique_zh":"电位滴定法","methodology_zh":"氯含量"},{"_id":"6a8369ecaf14b9c0e7b1dc55","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Odpady kod: 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, Wastes O) code: 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80","methodology":"Zawartość węgla całkowitego","parameters":[{"name":"Zakres","range":"(1,0 - 30,5) %"},{"name":"Total carbon content"},{"name":"Range","range":"(1,0 - 30,5) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR","High-temperature combustion method with IR detection"],"computed":[],"activity":"Zawartość węgla całkowitego\nZakres:\nZakres (1,0 - 30,5) %\nTotal carbon content\nRange (1,0 - 30,5) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04571:1998","norm_bases":["PN-G-04571:1998"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":"Kody odpadów podane według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów | Waste codes given according to the Regulation of the Minister of Climate on the waste catalogue","flexible":false,"search_text":"Odpady kod: 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, Wastes O) code: 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80 Zawartość węgla całkowitego\nZakres:\nZakres (1,0 - 30,5) %\nTotal carbon content\nRange (1,0 - 30,5) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04571:1998 Odpady kod: 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, Wastes O) code: 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80 Zawartosc wegla calkowitego\nZakres:\nZakres (1,0 - 30,5) %\nTotal carbon content\nRange (1,0 - 30,5) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04571:1998","categories":["environment"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total carbon content","parameters_en":[{"name":"Range","range":"(1,0 - 30,5) %"},{"name":"Total carbon content"},{"name":"Range","range":"(1,0 - 30,5) %"}],"search_en":"Total carbon content High-temperature combustion with IR detection Range Range PN-G-04571:1998","technique_en":"High-temperature combustion with IR detection","methodology_zh":"总碳含量","parameters_zh":[{"name":"范围","range":"(1,0 - 30,5) %"},{"name":"Total carbon content"},{"name":"范围","range":"(1,0 - 30,5) %"}],"search_zh":"总碳含量 高温燃烧红外检测法 范围 范围 PN-G-04571:1998","technique_zh":"高温燃烧红外检测法"},{"_id":"6a8369ecaf14b9c0e7b1dc56","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała - biopaliwo stałe, Solid fuels: Solid biomass - solid biofuel","methodology":"Zawartość wilgoci całkowitej","parameters":[{"name":"Zakres","range":"(1,5 - 75,5) %"},{"name":"Total moisture content"},{"name":"Range","range":"(1,5 - 75,5) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa","Gravimetric method"],"computed":[],"activity":"Zawartość wilgoci całkowitej\nZakres:\nZakres (1,5 - 75,5) %\nTotal moisture content\nRange (1,5 - 75,5) %\nMetoda wagowa","reference":"PN-EN ISO 18134-1:2023-02","norm_bases":["PN-EN ISO 18134-1:2023-02"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":"Kody odpadów podane według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów | Waste codes given according to the Regulation of the Minister of Climate on the waste catalogue","flexible":false,"search_text":"Paliwa stałe: biomasa stała - biopaliwo stałe, Solid fuels: Solid biomass - solid biofuel Zawartość wilgoci całkowitej\nZakres:\nZakres (1,5 - 75,5) %\nTotal moisture content\nRange (1,5 - 75,5) %\nMetoda wagowa PN-EN ISO 18134-1:2023-02 Paliwa stale: biomasa stala - biopaliwo stale, Solid fuels: Solid biomass - solid biofuel Zawartosc wilgoci calkowitej\nZakres:\nZakres (1,5 - 75,5) %\nTotal moisture content\nRange (1,5 - 75,5) %\nMetoda wagowa PN-EN ISO 18134-1:2023-02","categories":["petro"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total moisture content","parameters_en":[{"name":"Range","range":"(1,5 - 75,5) %"},{"name":"Total moisture content"},{"name":"Range","range":"(1,5 - 75,5) %"}],"search_en":"Total moisture content Gravimetric method Range Range PN-EN ISO 18134-1:2023-02","technique_en":"Gravimetric method","methodology_zh":"全水分含量","parameters_zh":[{"name":"范围","range":"(1,5 - 75,5) %"},{"name":"Total moisture content"},{"name":"范围","range":"(1,5 - 75,5) %"}],"search_zh":"全水分含量 重量法 范围 范围 PN-EN ISO 18134-1:2023-02","technique_zh":"重量法"},{"_id":"6a8369ecaf14b9c0e7b1dc57","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała - biopaliwo stałe, Solid fuels: Solid biomass - solid biofuel","methodology":"Zawartość wilgoci w próbce analitycznej","parameters":[{"name":"Zakres","range":"(1,5 - 16,2) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa","Gravimetric method"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (1,5 - 16,2) %\nMetoda wagowa","reference":"PN-EN ISO 18134-3:2023-12","norm_bases":["PN-EN ISO 18134-3:2023-12"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":"Kody odpadów podane według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów | Waste codes given according to the Regulation of the Minister of Climate on the waste catalogue","flexible":false,"search_text":"Paliwa stałe: biomasa stała - biopaliwo stałe, Solid fuels: Solid biomass - solid biofuel Zawartość wilgoci w próbce analitycznej\nZakres (1,5 - 16,2) %\nMetoda wagowa PN-EN ISO 18134-3:2023-12 Paliwa stale: biomasa stala - biopaliwo stale, Solid fuels: Solid biomass - solid biofuel Zawartosc wilgoci w probce analitycznej\nZakres (1,5 - 16,2) %\nMetoda wagowa PN-EN ISO 18134-3:2023-12","categories":["petro"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Moisture content in the analytical sample","parameters_en":[{"name":"Range","range":"(1,5 - 16,2) %"}],"search_en":"Moisture content in the analytical sample Gravimetric method Range PN-EN ISO 18134-3:2023-12","technique_en":"Gravimetric method","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(1,5 - 16,2) %"}],"search_zh":"分析样品水分含量 重量法 范围 PN-EN ISO 18134-3:2023-12","technique_zh":"重量法"},{"_id":"6a8369ecaf14b9c0e7b1dc58","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała - biopaliwo stałe, Solid fuels: Solid biomass - solid biofuel","methodology":"Zawartość wilgoci w próbce analitycznej","parameters":[{"name":"Zakres","range":"(1,5 - 10,0) %"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)","Thermogravimetric method (TGA)"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (1,5 - 10,0) %\nMetoda termograwimetryczna (TGA)","reference":"PN-EN ISO 18134-3:2023-12","norm_bases":["PN-EN ISO 18134-3:2023-12"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":"Kody odpadów podane według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów | Waste codes given according to the Regulation of the Minister of Climate on the waste catalogue","flexible":false,"search_text":"Paliwa stałe: biomasa stała - biopaliwo stałe, Solid fuels: Solid biomass - solid biofuel Zawartość wilgoci w próbce analitycznej\nZakres (1,5 - 10,0) %\nMetoda termograwimetryczna (TGA) PN-EN ISO 18134-3:2023-12 Paliwa stale: biomasa stala - biopaliwo stale, Solid fuels: Solid biomass - solid biofuel Zawartosc wilgoci w probce analitycznej\nZakres (1,5 - 10,0) %\nMetoda termograwimetryczna (TGA) PN-EN ISO 18134-3:2023-12","categories":["petro"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Moisture content in the analytical sample","parameters_en":[{"name":"Range","range":"(1,5 - 10,0) %"}],"search_en":"Moisture content in the analytical sample Thermogravimetric method (TGA) Range PN-EN ISO 18134-3:2023-12","technique_en":"Thermogravimetric method (TGA)","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(1,5 - 10,0) %"}],"search_zh":"分析样品水分含量 热重法（TGA） 范围 PN-EN ISO 18134-3:2023-12","technique_zh":"热重法（TGA）"},{"_id":"6a8369ecaf14b9c0e7b1dc59","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała - biopaliwo stałe, Solid fuels: Solid biomass - solid biofuel","methodology":"Zawartość popiołu","parameters":[{"name":"Zakres","range":"(0,2 - 67,8) %"},{"name":"Ash content"},{"name":"Range","range":"(0,2 - 67,8) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa","Gravimetric method"],"computed":[],"activity":"Zawartość popiołu\nZakres:\nZakres (0,2 - 67,8) %\nAsh content\nRange (0,2 - 67,8) %\nMetoda wagowa","reference":"PN-EN ISO 18122:2023-05","norm_bases":["PN-EN ISO 18122:2023-05"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":"Kody odpadów podane według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów | Waste codes given according to the Regulation of the Minister of Climate on the waste catalogue","flexible":false,"search_text":"Paliwa stałe: biomasa stała - biopaliwo stałe, Solid fuels: Solid biomass - solid biofuel Zawartość popiołu\nZakres:\nZakres (0,2 - 67,8) %\nAsh content\nRange (0,2 - 67,8) %\nMetoda wagowa PN-EN ISO 18122:2023-05 Paliwa stale: biomasa stala - biopaliwo stale, Solid fuels: Solid biomass - solid biofuel Zawartosc popiolu\nZakres:\nZakres (0,2 - 67,8) %\nAsh content\nRange (0,2 - 67,8) %\nMetoda wagowa PN-EN ISO 18122:2023-05","categories":["petro"],"row_index":55,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ash content","parameters_en":[{"name":"Range","range":"(0,2 - 67,8) %"},{"name":"Ash content"},{"name":"Range","range":"(0,2 - 67,8) %"}],"search_en":"Ash content Gravimetric method Range Ash content Range PN-EN ISO 18122:2023-05","technique_en":"Gravimetric method","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(0,2 - 67,8) %"},{"name":"Ash content"},{"name":"范围","range":"(0,2 - 67,8) %"}],"search_zh":"灰分含量 重量法 范围 范围 PN-EN ISO 18122:2023-05","technique_zh":"重量法"},{"_id":"6a8369ecaf14b9c0e7b1dc5a","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała - biopaliwo stałe, Solid fuels: Solid biomass - solid biofuel","methodology":"Zawartość popiołu","parameters":[{"name":"Zakres","range":"(0,2 - 68,5) %"},{"name":"Ash content"},{"name":"Range","range":"(0,2 - 68,5) %"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)","Thermogravimetric method (TGA)"],"computed":[],"activity":"Zawartość popiołu\nZakres:\nZakres (0,2 - 68,5) %\nAsh content\nRange (0,2 - 68,5) %\nMetoda termograwimetryczna (TGA)","reference":"PN-EN ISO 18122:2023-05","norm_bases":["PN-EN ISO 18122:2023-05"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":"Kody odpadów podane według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów | Waste codes given according to the Regulation of the Minister of Climate on the waste catalogue","flexible":false,"search_text":"Paliwa stałe: biomasa stała - biopaliwo stałe, Solid fuels: Solid biomass - solid biofuel Zawartość popiołu\nZakres:\nZakres (0,2 - 68,5) %\nAsh content\nRange (0,2 - 68,5) %\nMetoda termograwimetryczna (TGA) PN-EN ISO 18122:2023-05 Paliwa stale: biomasa stala - biopaliwo stale, Solid fuels: Solid biomass - solid biofuel Zawartosc popiolu\nZakres:\nZakres (0,2 - 68,5) %\nAsh content\nRange (0,2 - 68,5) %\nMetoda termograwimetryczna (TGA) PN-EN ISO 18122:2023-05","categories":["petro"],"row_index":56,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ash content","parameters_en":[{"name":"Range","range":"(0,2 - 68,5) %"},{"name":"Ash content"},{"name":"Range","range":"(0,2 - 68,5) %"}],"search_en":"Ash content Thermogravimetric method (TGA) Range Ash content Range PN-EN ISO 18122:2023-05","technique_en":"Thermogravimetric method (TGA)","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(0,2 - 68,5) %"},{"name":"Ash content"},{"name":"范围","range":"(0,2 - 68,5) %"}],"search_zh":"灰分含量 热重法（TGA） 范围 范围 PN-EN ISO 18122:2023-05","technique_zh":"热重法（TGA）"},{"_id":"6a8369ecaf14b9c0e7b1dc5b","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała - biopaliwo stałe, Solid fuels: Solid biomass - solid biofuel","methodology":"Części lotne","parameters":[{"name":"Zakres","range":"(45,1 - 88,3) %"},{"name":"Volatile matter content"},{"name":"Range","range":"(45,1 - 88,3) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa","Gravimetric method"],"computed":[],"activity":"Części lotne\nZakres:\nZakres (45,1 - 88,3) %\nVolatile matter content\nRange (45,1 - 88,3) %\nMetoda wagowa","reference":"PN-EN ISO 18123:2023-10","norm_bases":["PN-EN ISO 18123:2023-10"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":"Kody odpadów podane według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów | Waste codes given according to the Regulation of the Minister of Climate on the waste catalogue","flexible":false,"search_text":"Paliwa stałe: biomasa stała - biopaliwo stałe, Solid fuels: Solid biomass - solid biofuel Części lotne\nZakres:\nZakres (45,1 - 88,3) %\nVolatile matter content\nRange (45,1 - 88,3) %\nMetoda wagowa PN-EN ISO 18123:2023-10 Paliwa stale: biomasa stala - biopaliwo stale, Solid fuels: Solid biomass - solid biofuel Czesci lotne\nZakres:\nZakres (45,1 - 88,3) %\nVolatile matter content\nRange (45,1 - 88,3) %\nMetoda wagowa PN-EN ISO 18123:2023-10","categories":["petro"],"row_index":57,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Volatile matter","parameters_en":[{"name":"Range","range":"(45,1 - 88,3) %"},{"name":"Volatile matter content"},{"name":"Range","range":"(45,1 - 88,3) %"}],"search_en":"Volatile matter Gravimetric method Range Range PN-EN ISO 18123:2023-10","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(45,1 - 88,3) %"},{"name":"Volatile matter content"},{"name":"范围","range":"(45,1 - 88,3) %"}],"search_zh":"重量法 范围 范围 PN-EN ISO 18123:2023-10","technique_zh":"重量法"},{"_id":"6a8369ecaf14b9c0e7b1dc5c","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała - biopaliwo stałe, Solid fuels: Solid biomass - solid biofuel","methodology":"Zawartość siarki całkowitej","parameters":[{"name":"Zakres","range":"(0,01 - 1,00) %"},{"name":"Total sulphur content"},{"name":"Range","range":"(0,01 - 1,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR","High-temperature combustion method with IR detection"],"computed":[],"activity":"Zawartość siarki całkowitej\nZakres:\nZakres (0,01 - 1,00) %\nTotal sulphur content\nRange (0,01 - 1,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN ISO 16994:2016-10","norm_bases":["PN-EN ISO 16994:2016-10"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała - biopaliwo stałe, Solid fuels: Solid biomass - solid biofuel Zawartość siarki całkowitej\nZakres:\nZakres (0,01 - 1,00) %\nTotal sulphur content\nRange (0,01 - 1,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN ISO 16994:2016-10 Paliwa stale: biomasa stala - biopaliwo stale, Solid fuels: Solid biomass - solid biofuel Zawartosc siarki calkowitej\nZakres:\nZakres (0,01 - 1,00) %\nTotal sulphur content\nRange (0,01 - 1,00) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN ISO 16994:2016-10","categories":["petro"],"row_index":58,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total sulfur content","parameters_en":[{"name":"Range","range":"(0,01 - 1,00) %"},{"name":"Total sulphur content"},{"name":"Range","range":"(0,01 - 1,00) %"}],"search_en":"Total sulfur content High-temperature combustion with IR detection Range Range PN-EN ISO 16994:2016-10","technique_en":"High-temperature combustion with IR detection","methodology_zh":"全硫含量","parameters_zh":[{"name":"范围","range":"(0,01 - 1,00) %"},{"name":"Total sulphur content"},{"name":"范围","range":"(0,01 - 1,00) %"}],"search_zh":"全硫含量 高温燃烧红外检测法 范围 范围 PN-EN ISO 16994:2016-10","technique_zh":"高温燃烧红外检测法"},{"_id":"6a8369ecaf14b9c0e7b1dc5d","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała - biopaliwo stałe, Solid fuels: Solid biomass - solid biofuel","methodology":"Zawartość węgla całkowitego","parameters":[{"name":"Zakres","range":"(38,0 - 70,0) %"},{"name":"Total carbon content"},{"name":"Range","range":"(38,0 - 70,0) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR","High-temperature combustion method with IR detection"],"computed":[],"activity":"Zawartość węgla całkowitego\nZakres:\nZakres (38,0 - 70,0) %\nTotal carbon content\nRange (38,0 - 70,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN ISO 16948:2015-07","norm_bases":["PN-EN ISO 16948:2015-07"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała - biopaliwo stałe, Solid fuels: Solid biomass - solid biofuel Zawartość węgla całkowitego\nZakres:\nZakres (38,0 - 70,0) %\nTotal carbon content\nRange (38,0 - 70,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN ISO 16948:2015-07 Paliwa stale: biomasa stala - biopaliwo stale, Solid fuels: Solid biomass - solid biofuel Zawartosc wegla calkowitego\nZakres:\nZakres (38,0 - 70,0) %\nTotal carbon content\nRange (38,0 - 70,0) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN ISO 16948:2015-07","categories":["petro"],"row_index":59,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total carbon content","parameters_en":[{"name":"Range","range":"(38,0 - 70,0) %"},{"name":"Total carbon content"},{"name":"Range","range":"(38,0 - 70,0) %"}],"search_en":"Total carbon content High-temperature combustion with IR detection Range Range PN-EN ISO 16948:2015-07","technique_en":"High-temperature combustion with IR detection","methodology_zh":"总碳含量","parameters_zh":[{"name":"范围","range":"(38,0 - 70,0) %"},{"name":"Total carbon content"},{"name":"范围","range":"(38,0 - 70,0) %"}],"search_zh":"总碳含量 高温燃烧红外检测法 范围 范围 PN-EN ISO 16948:2015-07","technique_zh":"高温燃烧红外检测法"},{"_id":"6a8369ecaf14b9c0e7b1dc5e","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała - biopaliwo stałe, Solid fuels: Solid biomass - solid biofuel","methodology":"Zawartość wodoru","parameters":[{"name":"Zakres","range":"(3,15 - 7,54) %"},{"name":"Hydrogen content"},{"name":"Range","range":"(3,15 - 7,54) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR","High-temperature combustion method with IR detection"],"computed":[],"activity":"Zawartość wodoru\nZakres:\nZakres (3,15 - 7,54) %\nHydrogen content\nRange (3,15 - 7,54) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN ISO 16948:2015-07","norm_bases":["PN-EN ISO 16948:2015-07"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała - biopaliwo stałe, Solid fuels: Solid biomass - solid biofuel Zawartość wodoru\nZakres:\nZakres (3,15 - 7,54) %\nHydrogen content\nRange (3,15 - 7,54) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN ISO 16948:2015-07 Paliwa stale: biomasa stala - biopaliwo stale, Solid fuels: Solid biomass - solid biofuel Zawartosc wodoru\nZakres:\nZakres (3,15 - 7,54) %\nHydrogen content\nRange (3,15 - 7,54) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN ISO 16948:2015-07","categories":["petro"],"row_index":60,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrogen content","parameters_en":[{"name":"Range","range":"(3,15 - 7,54) %"},{"name":"Hydrogen content"},{"name":"Range","range":"(3,15 - 7,54) %"}],"search_en":"Hydrogen content High-temperature combustion with IR detection Range Range PN-EN ISO 16948:2015-07","technique_en":"High-temperature combustion with IR detection","parameters_zh":[{"name":"范围","range":"(3,15 - 7,54) %"},{"name":"Hydrogen content"},{"name":"范围","range":"(3,15 - 7,54) %"}],"search_zh":"氢含量 高温燃烧红外检测法 范围 范围 PN-EN ISO 16948:2015-07","technique_zh":"高温燃烧红外检测法","methodology_zh":"氢含量"},{"_id":"6a8369ecaf14b9c0e7b1dc5f","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała - biopaliwo stałe, Solid fuels: Solid biomass - solid biofuel","methodology":"Zawartość azotu","parameters":[{"name":"Zakres","range":"(0,06 - 4,40) %"},{"name":"Nitrogen content"},{"name":"Range","range":"(0,06 - 4,40) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją TC","techniques":["Metoda wysokotemperaturowego spalania z detekcją TC","High-temperature combustion method with TC detection"],"computed":[],"activity":"Zawartość azotu\nZakres:\nZakres (0,06 - 4,40) %\nNitrogen content\nRange (0,06 - 4,40) %\nMetoda wysokotemperaturowego spalania z detekcją TC","reference":"PN-EN ISO 16948:2015-07","norm_bases":["PN-EN ISO 16948:2015-07"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała - biopaliwo stałe, Solid fuels: Solid biomass - solid biofuel Zawartość azotu\nZakres:\nZakres (0,06 - 4,40) %\nNitrogen content\nRange (0,06 - 4,40) %\nMetoda wysokotemperaturowego spalania z detekcją TC PN-EN ISO 16948:2015-07 Paliwa stale: biomasa stala - biopaliwo stale, Solid fuels: Solid biomass - solid biofuel Zawartosc azotu\nZakres:\nZakres (0,06 - 4,40) %\nNitrogen content\nRange (0,06 - 4,40) %\nMetoda wysokotemperaturowego spalania z detekcja TC PN-EN ISO 16948:2015-07","categories":["petro"],"row_index":61,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrogen content","parameters_en":[{"name":"Range","range":"(0,06 - 4,40) %"},{"name":"Nitrogen content"},{"name":"Range","range":"(0,06 - 4,40) %"}],"search_en":"Nitrogen content High-temperature combustion with TC detection Range Range PN-EN ISO 16948:2015-07","technique_en":"High-temperature combustion with TC detection","methodology_zh":"氮含量","parameters_zh":[{"name":"范围","range":"(0,06 - 4,40) %"},{"name":"Nitrogen content"},{"name":"范围","range":"(0,06 - 4,40) %"}],"search_zh":"氮含量 高温燃烧总碳检测法 范围 范围 PN-EN ISO 16948:2015-07","technique_zh":"高温燃烧总碳检测法"},{"_id":"6a8369ecaf14b9c0e7b1dc60","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała - biopaliwo stałe, Solid fuels: Solid biomass - solid biofuel","methodology":"Ciepło spalania","parameters":[{"name":"Zakres","range":"(8600 - 28140) kJ/kg"},{"name":"Wartość opałowa (z obliczeń) Gross calorific value"},{"name":"Range","range":"(8600 - 28140) kJ/kg"}],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna","Calorimetric method"],"computed":[],"activity":"Ciepło spalania\nZakres:\nZakres (8600 - 28140) kJ/kg\nWartość opałowa (z obliczeń) Gross calorific value\nRange (8600 - 28140) kJ/kg\nMetoda kalorymetryczna","reference":"PN-EN ISO 18125:2017-07","norm_bases":["PN-EN ISO 18125:2017-07"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała - biopaliwo stałe, Solid fuels: Solid biomass - solid biofuel Ciepło spalania\nZakres:\nZakres (8600 - 28140) kJ/kg\nWartość opałowa (z obliczeń) Gross calorific value\nRange (8600 - 28140) kJ/kg\nMetoda kalorymetryczna PN-EN ISO 18125:2017-07 Paliwa stale: biomasa stala - biopaliwo stale, Solid fuels: Solid biomass - solid biofuel Cieplo spalania\nZakres:\nZakres (8600 - 28140) kJ/kg\nWartosc opalowa (z obliczen) Gross calorific value\nRange (8600 - 28140) kJ/kg\nMetoda kalorymetryczna PN-EN ISO 18125:2017-07","categories":["petro"],"row_index":62,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gross calorific value","parameters_en":[{"name":"Range","range":"(8600 - 28140) kJ/kg"},{"name":"Wartość opałowa (z obliczeń) Gross calorific value"},{"name":"Range","range":"(8600 - 28140) kJ/kg"}],"search_en":"Gross calorific value Calorimetric method Range Range PN-EN ISO 18125:2017-07","technique_en":"Calorimetric method","methodology_zh":"高位发热量","parameters_zh":[{"name":"范围","range":"(8600 - 28140) kJ/kg"},{"name":"Wartość opałowa (z obliczeń) Gross calorific value"},{"name":"范围","range":"(8600 - 28140) kJ/kg"}],"search_zh":"高位发热量 量热法 范围 范围 PN-EN ISO 18125:2017-07","technique_zh":"量热法"},{"_id":"6a8369ecaf14b9c0e7b1dc61","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała - biopaliwo stałe, Solid fuels: Solid biomass - solid biofuel","methodology":"Gęstość nasypowa","parameters":[{"name":"Zakres","range":"(160 - 770) kg/m3"},{"name":"Bulk density"},{"name":"Range","range":"(160 - 770) kg/m3"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa","Gravimetric method"],"computed":[],"activity":"Gęstość nasypowa\nZakres:\nZakres (160 - 770) kg/m3\nBulk density\nRange (160 - 770) kg/m3\nMetoda wagowa","reference":"PN-EN ISO 17828:2025-09 z wyłączeniem pkt. 7.3.2 | PN-EN ISO 17828:2025-09 excluding p. 7.3.2","norm_bases":["PN-EN ISO 17828:2025-09 z wyłączeniem pkt. 7.3.2","PN-EN ISO 17828:2025-09 excluding p. 7.3.2"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała - biopaliwo stałe, Solid fuels: Solid biomass - solid biofuel Gęstość nasypowa\nZakres:\nZakres (160 - 770) kg/m3\nBulk density\nRange (160 - 770) kg/m3\nMetoda wagowa PN-EN ISO 17828:2025-09 z wyłączeniem pkt. 7.3.2 | PN-EN ISO 17828:2025-09 excluding p. 7.3.2 Paliwa stale: biomasa stala - biopaliwo stale, Solid fuels: Solid biomass - solid biofuel Gestosc nasypowa\nZakres:\nZakres (160 - 770) kg/m3\nBulk density\nRange (160 - 770) kg/m3\nMetoda wagowa PN-EN ISO 17828:2025-09 z wylaczeniem pkt. 7.3.2 | PN-EN ISO 17828:2025-09 excluding p. 7.3.2","categories":["petro"],"row_index":63,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Bulk density","parameters_en":[{"name":"Range","range":"(160 - 770) kg/m3"},{"name":"Bulk density"},{"name":"Range","range":"(160 - 770) kg/m3"}],"search_en":"Bulk density Gravimetric method Range Bulk density Range PN-EN ISO 17828:2025-09 z wyłączeniem pkt. 7.3.2 | PN-EN ISO 17828:2025-09 excluding p. 7.3.2","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(160 - 770) kg/m3"},{"name":"Bulk density"},{"name":"范围","range":"(160 - 770) kg/m3"}],"search_zh":"堆积密度 重量法 范围 范围 PN-EN ISO 17828:2025-09 z wyłączeniem pkt. 7.3.2 | PN-EN ISO 17828:2025-09 excluding p. 7.3.2","technique_zh":"重量法","methodology_zh":"堆积密度"},{"_id":"6a8369ecaf14b9c0e7b1dc62","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała - biopaliwo stałe, Solid fuels: Solid biomass - solid biofuel","methodology":"Wytrzymałość mechaniczna peletów","parameters":[{"name":"Zakres","range":"(85,8 - 99,5) %"},{"name":"Mechanical durability of pellets"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa","Gravimetric method"],"computed":[],"activity":"Wytrzymałość mechaniczna peletów\nZakres:\nZakres (85,8 - 99,5) %\nMechanical durability of pellets\nMetoda wagowa","reference":"PN-EN ISO 17831-1:2025-10","norm_bases":["PN-EN ISO 17831-1:2025-10"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała - biopaliwo stałe, Solid fuels: Solid biomass - solid biofuel Wytrzymałość mechaniczna peletów\nZakres:\nZakres (85,8 - 99,5) %\nMechanical durability of pellets\nMetoda wagowa PN-EN ISO 17831-1:2025-10 Paliwa stale: biomasa stala - biopaliwo stale, Solid fuels: Solid biomass - solid biofuel Wytrzymalosc mechaniczna peletow\nZakres:\nZakres (85,8 - 99,5) %\nMechanical durability of pellets\nMetoda wagowa PN-EN ISO 17831-1:2025-10","categories":["petro"],"row_index":64,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mechanical durability of pellets","parameters_en":[{"name":"Range","range":"(85,8 - 99,5) %"},{"name":"Mechanical durability of pellets"}],"search_en":"Mechanical durability of pellets Gravimetric method Range PN-EN ISO 17831-1:2025-10","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(85,8 - 99,5) %"},{"name":"Mechanical durability of pellets"}],"search_zh":"颗粒燃料机械耐久性 重量法 范围 PN-EN ISO 17831-1:2025-10","technique_zh":"重量法","methodology_zh":"颗粒燃料机械耐久性"},{"_id":"6a8369ecaf14b9c0e7b1dc63","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała - biopaliwo stałe, Solid fuels: Solid biomass - solid biofuel","methodology":"Długość peletów","parameters":[{"name":"Zakres","range":"(3,0 - 66,0) mm"},{"name":"Średnica peletów"},{"name":"Zakres","range":"(5,5 - 13,5) mm"}],"technique":"Metoda pomiaru liniowego","techniques":["Metoda pomiaru liniowego","Linear measurement method"],"computed":[],"activity":"Długość peletów\nZakres:\nZakres (3,0 - 66,0) mm\nŚrednica peletów\nZakres (5,5 - 13,5) mm\nMetoda pomiaru liniowego","reference":"PN-EN ISO 17829:2016-02","norm_bases":["PN-EN ISO 17829:2016-02"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała - biopaliwo stałe, Solid fuels: Solid biomass - solid biofuel Długość peletów\nZakres:\nZakres (3,0 - 66,0) mm\nŚrednica peletów\nZakres (5,5 - 13,5) mm\nMetoda pomiaru liniowego PN-EN ISO 17829:2016-02 Paliwa stale: biomasa stala - biopaliwo stale, Solid fuels: Solid biomass - solid biofuel Dlugosc peletow\nZakres:\nZakres (3,0 - 66,0) mm\nSrednica peletow\nZakres (5,5 - 13,5) mm\nMetoda pomiaru liniowego PN-EN ISO 17829:2016-02","categories":["petro"],"row_index":65,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Length of pellets","parameters_en":[{"name":"Range","range":"(3,0 - 66,0) mm"},{"name":"Pellet diameter"},{"name":"Range","range":"(5,5 - 13,5) mm"}],"search_en":"Length of pellets Linear measurement method Range Pellet diameter Range PN-EN ISO 17829:2016-02","technique_en":"Linear measurement method","parameters_zh":[{"name":"范围","range":"(3,0 - 66,0) mm"},{"name":"Średnica peletów"},{"name":"范围","range":"(5,5 - 13,5) mm"}],"search_zh":"线性测量法 范围 范围 PN-EN ISO 17829:2016-02","technique_zh":"线性测量法"},{"_id":"6a8369ecaf14b9c0e7b1dc64","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała - biopaliwo stałe, Solid fuels: Solid biomass - solid biofuel","methodology":"Zawartość podziarna < 3,15 mm w peletach","parameters":[{"name":"Zakres","range":"(0,1 - 29,5) %"},{"name":"Zawartość frakcji gruboziarnistej 3,15 mm ≤ CPF < 5,6 mm"},{"name":"Zakres","range":"(0,1 - 26,0) %"},{"name":"Fines content <3,15mm in pellets"},{"name":"Range","range":"(0,1 - 29,5) %"},{"name":"Coarse pellet fines 3,15 mm ≤ CPF < 5,6 mm"},{"name":"Range","range":"(0,1 - 26,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa","Gravimetric method"],"computed":[],"activity":"Zawartość podziarna < 3,15 mm w peletach\nZakres:\nZakres (0,1 - 29,5) %\nZawartość frakcji gruboziarnistej 3,15 mm ≤ CPF < 5,6 mm\nZakres (0,1 - 26,0) %\nFines content <3,15mm in pellets\nRange (0,1 - 29,5) %\nCoarse pellet fines 3,15 mm ≤ CPF < 5,6 mm\nRange (0,1 - 26,0) %\nMetoda wagowa","reference":"PN-EN ISO 5370:2023-08","norm_bases":["PN-EN ISO 5370:2023-08"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała - biopaliwo stałe, Solid fuels: Solid biomass - solid biofuel Zawartość podziarna < 3,15 mm w peletach\nZakres:\nZakres (0,1 - 29,5) %\nZawartość frakcji gruboziarnistej 3,15 mm ≤ CPF < 5,6 mm\nZakres (0,1 - 26,0) %\nFines content <3,15mm in pellets\nRange (0,1 - 29,5) %\nCoarse pellet fines 3,15 mm ≤ CPF < 5,6 mm\nRange (0,1 - 26,0) %\nMetoda wagowa PN-EN ISO 5370:2023-08 Paliwa stale: biomasa stala - biopaliwo stale, Solid fuels: Solid biomass - solid biofuel Zawartosc podziarna < 3,15 mm w peletach\nZakres:\nZakres (0,1 - 29,5) %\nZawartosc frakcji gruboziarnistej 3,15 mm ≤ CPF < 5,6 mm\nZakres (0,1 - 26,0) %\nFines content <3,15mm in pellets\nRange (0,1 - 29,5) %\nCoarse pellet fines 3,15 mm ≤ CPF < 5,6 mm\nRange (0,1 - 26,0) %\nMetoda wagowa PN-EN ISO 5370:2023-08","categories":["petro"],"row_index":66,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Undersize content < 3,15 mm in pellets","parameters_en":[{"name":"Range","range":"(0,1 - 29,5) %"},{"name":"Content of the coarse fraction 3,15 mm ≤ CPF < 5,6 mm"},{"name":"Range","range":"(0,1 - 26,0) %"},{"name":"Fines content <3,15mm in pellets"},{"name":"Range","range":"(0,1 - 29,5) %"},{"name":"Coarse pellet fines 3,15 mm ≤ CPF < 5,6 mm"},{"name":"Range","range":"(0,1 - 26,0) %"}],"search_en":"Undersize content < 3,15 mm in pellets Gravimetric method Range Content of the coarse fraction 3,15 mm ≤ CPF < 5,6 mm Range Range Range PN-EN ISO 5370:2023-08","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(0,1 - 29,5) %"},{"name":"Zawartość frakcji gruboziarnistej 3,15 mm ≤ CPF < 5,6 mm"},{"name":"范围","range":"(0,1 - 26,0) %"},{"name":"Fines content <3,15mm in pellets"},{"name":"范围","range":"(0,1 - 29,5) %"},{"name":"Coarse pellet fines 3,15 mm ≤ CPF < 5,6 mm"},{"name":"范围","range":"(0,1 - 26,0) %"}],"search_zh":"重量法 范围 范围 范围 范围 PN-EN ISO 5370:2023-08","technique_zh":"重量法"},{"_id":"6a8369ecaf14b9c0e7b1dc65","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała - biopaliwo stałe, Solid fuels: Solid biomass - solid biofuel","methodology":"Zawartość chloru","parameters":[{"name":"Zakres","range":"(0,006 - 0,520) %"},{"name":"Chlorine content"},{"name":"Range","range":"(0,006 - 0,520) %"}],"technique":"Metoda miareczkowania potencjometrycznego","techniques":["Metoda miareczkowania potencjometrycznego","Potentiometric titration method"],"computed":[],"activity":"Zawartość chloru\nZakres:\nZakres (0,006 - 0,520) %\nChlorine content\nRange (0,006 - 0,520) %\nMetoda miareczkowania potencjometrycznego","reference":"PN-EN ISO 16994:2016-10","norm_bases":["PN-EN ISO 16994:2016-10"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała - biopaliwo stałe, Solid fuels: Solid biomass - solid biofuel Zawartość chloru\nZakres:\nZakres (0,006 - 0,520) %\nChlorine content\nRange (0,006 - 0,520) %\nMetoda miareczkowania potencjometrycznego PN-EN ISO 16994:2016-10 Paliwa stale: biomasa stala - biopaliwo stale, Solid fuels: Solid biomass - solid biofuel Zawartosc chloru\nZakres:\nZakres (0,006 - 0,520) %\nChlorine content\nRange (0,006 - 0,520) %\nMetoda miareczkowania potencjometrycznego PN-EN ISO 16994:2016-10","categories":["petro"],"row_index":67,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chlorine content","parameters_en":[{"name":"Range","range":"(0,006 - 0,520) %"},{"name":"Chlorine content"},{"name":"Range","range":"(0,006 - 0,520) %"}],"search_en":"Chlorine content Potentiometric titration method Range Range PN-EN ISO 16994:2016-10","technique_en":"Potentiometric titration method","parameters_zh":[{"name":"范围","range":"(0,006 - 0,520) %"},{"name":"Chlorine content"},{"name":"范围","range":"(0,006 - 0,520) %"}],"search_zh":"氯含量 电位滴定法 范围 范围 PN-EN ISO 16994:2016-10","technique_zh":"电位滴定法","methodology_zh":"氯含量"},{"_id":"6a8369ecaf14b9c0e7b1dc66","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała - biopaliwo stałe, Solid fuels: Solid biomass - solid biofuel","methodology":"Zawartość tlenu (z obliczeń), Oxygen content","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość tlenu (z obliczeń), Oxygen content","reference":"PN-EN ISO 18125:2017-07","norm_bases":["PN-EN ISO 18125:2017-07"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała - biopaliwo stałe, Solid fuels: Solid biomass - solid biofuel Zawartość tlenu (z obliczeń), Oxygen content PN-EN ISO 18125:2017-07 Paliwa stale: biomasa stala - biopaliwo stale, Solid fuels: Solid biomass - solid biofuel Zawartosc tlenu (z obliczen), Oxygen content PN-EN ISO 18125:2017-07","categories":["petro"],"row_index":68,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a8369ecaf14b9c0e7b1dc67","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwa wtórne, Solid fuels: solid recovered fuels","methodology":"Zawartość wilgoci w próbce analitycznej","parameters":[{"name":"Zakres","range":"(1,0 - 10,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa","Gravimetric method"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (1,0 - 10,0) %\nMetoda wagowa","reference":"PN-EN ISO 21660-3:2021-08","norm_bases":["PN-EN ISO 21660-3:2021-08"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: stałe paliwa wtórne, Solid fuels: solid recovered fuels Zawartość wilgoci w próbce analitycznej\nZakres (1,0 - 10,0) %\nMetoda wagowa PN-EN ISO 21660-3:2021-08 Paliwa stale: stale paliwa wtorne, Solid fuels: solid recovered fuels Zawartosc wilgoci w probce analitycznej\nZakres (1,0 - 10,0) %\nMetoda wagowa PN-EN ISO 21660-3:2021-08","categories":["petro"],"row_index":69,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Moisture content in the analytical sample","parameters_en":[{"name":"Range","range":"(1,0 - 10,0) %"}],"search_en":"Moisture content in the analytical sample Gravimetric method Range PN-EN ISO 21660-3:2021-08","technique_en":"Gravimetric method","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(1,0 - 10,0) %"}],"search_zh":"分析样品水分含量 重量法 范围 PN-EN ISO 21660-3:2021-08","technique_zh":"重量法"},{"_id":"6a8369ecaf14b9c0e7b1dc68","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwa wtórne, Solid fuels: solid recovered fuels","methodology":"Zawartość popiołu","parameters":[{"name":"Zakres","range":"(1,5 - 90,0) %"},{"name":"Ash content"},{"name":"Range","range":"(1,5 - 90,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa","Gravimetric method"],"computed":[],"activity":"Zawartość popiołu\nZakres:\nZakres (1,5 - 90,0) %\nAsh content\nRange (1,5 - 90,0) %\nMetoda wagowa","reference":"PN-EN ISO 21656:2021-08","norm_bases":["PN-EN ISO 21656:2021-08"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: stałe paliwa wtórne, Solid fuels: solid recovered fuels Zawartość popiołu\nZakres:\nZakres (1,5 - 90,0) %\nAsh content\nRange (1,5 - 90,0) %\nMetoda wagowa PN-EN ISO 21656:2021-08 Paliwa stale: stale paliwa wtorne, Solid fuels: solid recovered fuels Zawartosc popiolu\nZakres:\nZakres (1,5 - 90,0) %\nAsh content\nRange (1,5 - 90,0) %\nMetoda wagowa PN-EN ISO 21656:2021-08","categories":["petro"],"row_index":70,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ash content","parameters_en":[{"name":"Range","range":"(1,5 - 90,0) %"},{"name":"Ash content"},{"name":"Range","range":"(1,5 - 90,0) %"}],"search_en":"Ash content Gravimetric method Range Ash content Range PN-EN ISO 21656:2021-08","technique_en":"Gravimetric method","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(1,5 - 90,0) %"},{"name":"Ash content"},{"name":"范围","range":"(1,5 - 90,0) %"}],"search_zh":"灰分含量 重量法 范围 范围 PN-EN ISO 21656:2021-08","technique_zh":"重量法"},{"_id":"6a8369ecaf14b9c0e7b1dc69","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwa wtórne, Solid fuels: solid recovered fuels","methodology":"Zawartość części lotnych","parameters":[{"name":"Zakres","range":"(12,0 - 90,0) %"},{"name":"Volatile matter content"},{"name":"Range","range":"(12,0 - 90,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa","Gravimetric method"],"computed":[],"activity":"Zawartość części lotnych\nZakres:\nZakres (12,0 - 90,0) %\nVolatile matter content\nRange (12,0 - 90,0) %\nMetoda wagowa","reference":"PN-EN ISO 22167:2021-08","norm_bases":["PN-EN ISO 22167:2021-08"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: stałe paliwa wtórne, Solid fuels: solid recovered fuels Zawartość części lotnych\nZakres:\nZakres (12,0 - 90,0) %\nVolatile matter content\nRange (12,0 - 90,0) %\nMetoda wagowa PN-EN ISO 22167:2021-08 Paliwa stale: stale paliwa wtorne, Solid fuels: solid recovered fuels Zawartosc czesci lotnych\nZakres:\nZakres (12,0 - 90,0) %\nVolatile matter content\nRange (12,0 - 90,0) %\nMetoda wagowa PN-EN ISO 22167:2021-08","categories":["petro"],"row_index":71,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Volatile matter content","parameters_en":[{"name":"Range","range":"(12,0 - 90,0) %"},{"name":"Volatile matter content"},{"name":"Range","range":"(12,0 - 90,0) %"}],"search_en":"Volatile matter content Gravimetric method Range Range PN-EN ISO 22167:2021-08","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(12,0 - 90,0) %"},{"name":"Volatile matter content"},{"name":"范围","range":"(12,0 - 90,0) %"}],"search_zh":"挥发分含量 重量法 范围 范围 PN-EN ISO 22167:2021-08","technique_zh":"重量法","methodology_zh":"挥发分含量"},{"_id":"6a8369ecaf14b9c0e7b1dc6a","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwa wtórne, Solid fuels: solid recovered fuels","methodology":"Zawartość siarki całkowitej","parameters":[{"name":"Zakres","range":"(0,18 - 2,40) %"},{"name":"Total sulphur content"},{"name":"Range","range":"(0,18 - 2,40) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR","High-temperature combustion method with IR detection"],"computed":[],"activity":"Zawartość siarki całkowitej\nZakres:\nZakres (0,18 - 2,40) %\nTotal sulphur content\nRange (0,18 - 2,40) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04584:2001 | ISO 19579:2006","norm_bases":["PN-G-04584:2001","ISO 19579:2006"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: stałe paliwa wtórne, Solid fuels: solid recovered fuels Zawartość siarki całkowitej\nZakres:\nZakres (0,18 - 2,40) %\nTotal sulphur content\nRange (0,18 - 2,40) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04584:2001 | ISO 19579:2006 Paliwa stale: stale paliwa wtorne, Solid fuels: solid recovered fuels Zawartosc siarki calkowitej\nZakres:\nZakres (0,18 - 2,40) %\nTotal sulphur content\nRange (0,18 - 2,40) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04584:2001 | ISO 19579:2006","categories":["petro"],"row_index":72,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total sulfur content","parameters_en":[{"name":"Range","range":"(0,18 - 2,40) %"},{"name":"Total sulphur content"},{"name":"Range","range":"(0,18 - 2,40) %"}],"search_en":"Total sulfur content High-temperature combustion with IR detection Range Range PN-G-04584:2001 | ISO 19579:2006","technique_en":"High-temperature combustion with IR detection","methodology_zh":"全硫含量","parameters_zh":[{"name":"范围","range":"(0,18 - 2,40) %"},{"name":"Total sulphur content"},{"name":"范围","range":"(0,18 - 2,40) %"}],"search_zh":"全硫含量 高温燃烧红外检测法 范围 范围 PN-G-04584:2001 | ISO 19579:2006","technique_zh":"高温燃烧红外检测法"},{"_id":"6a8369ecaf14b9c0e7b1dc6b","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwa wtórne, Solid fuels: solid recovered fuels","methodology":"Ciepło spalania","parameters":[{"name":"Zakres","range":"(2500 - 32000) kJ/kg"},{"name":"Wartość opałowa (z obliczeń) Gross calorific value"},{"name":"Range","range":"(2500 - 32000) kJ/kg"}],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna","Calorimetric method"],"computed":[],"activity":"Ciepło spalania\nZakres:\nZakres (2500 - 32000) kJ/kg\nWartość opałowa (z obliczeń) Gross calorific value\nRange (2500 - 32000) kJ/kg\nMetoda kalorymetryczna","reference":"PN-EN ISO 21654:2021-12","norm_bases":["PN-EN ISO 21654:2021-12"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: stałe paliwa wtórne, Solid fuels: solid recovered fuels Ciepło spalania\nZakres:\nZakres (2500 - 32000) kJ/kg\nWartość opałowa (z obliczeń) Gross calorific value\nRange (2500 - 32000) kJ/kg\nMetoda kalorymetryczna PN-EN ISO 21654:2021-12 Paliwa stale: stale paliwa wtorne, Solid fuels: solid recovered fuels Cieplo spalania\nZakres:\nZakres (2500 - 32000) kJ/kg\nWartosc opalowa (z obliczen) Gross calorific value\nRange (2500 - 32000) kJ/kg\nMetoda kalorymetryczna PN-EN ISO 21654:2021-12","categories":["petro"],"row_index":73,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gross calorific value","parameters_en":[{"name":"Range","range":"(2500 - 32000) kJ/kg"},{"name":"Wartość opałowa (z obliczeń) Gross calorific value"},{"name":"Range","range":"(2500 - 32000) kJ/kg"}],"search_en":"Gross calorific value Calorimetric method Range Range PN-EN ISO 21654:2021-12","technique_en":"Calorimetric method","methodology_zh":"高位发热量","parameters_zh":[{"name":"范围","range":"(2500 - 32000) kJ/kg"},{"name":"Wartość opałowa (z obliczeń) Gross calorific value"},{"name":"范围","range":"(2500 - 32000) kJ/kg"}],"search_zh":"高位发热量 量热法 范围 范围 PN-EN ISO 21654:2021-12","technique_zh":"量热法"},{"_id":"6a8369ecaf14b9c0e7b1dc6c","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwa wtórne, Solid fuels: solid recovered fuels","methodology":"Zawartość węgla całkowitego","parameters":[{"name":"Zakres","range":"(7,5 - 70,0) %"},{"name":"Total carbon content"},{"name":"Range","range":"(7,5 - 70,0) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR","High-temperature combustion method with IR detection"],"computed":[],"activity":"Zawartość węgla całkowitego\nZakres:\nZakres (7,5 - 70,0) %\nTotal carbon content\nRange (7,5 - 70,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN ISO 21663:2021-06","norm_bases":["PN-EN ISO 21663:2021-06"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: stałe paliwa wtórne, Solid fuels: solid recovered fuels Zawartość węgla całkowitego\nZakres:\nZakres (7,5 - 70,0) %\nTotal carbon content\nRange (7,5 - 70,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN ISO 21663:2021-06 Paliwa stale: stale paliwa wtorne, Solid fuels: solid recovered fuels Zawartosc wegla calkowitego\nZakres:\nZakres (7,5 - 70,0) %\nTotal carbon content\nRange (7,5 - 70,0) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN ISO 21663:2021-06","categories":["petro"],"row_index":74,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total carbon content","parameters_en":[{"name":"Range","range":"(7,5 - 70,0) %"},{"name":"Total carbon content"},{"name":"Range","range":"(7,5 - 70,0) %"}],"search_en":"Total carbon content High-temperature combustion with IR detection Range Range PN-EN ISO 21663:2021-06","technique_en":"High-temperature combustion with IR detection","methodology_zh":"总碳含量","parameters_zh":[{"name":"范围","range":"(7,5 - 70,0) %"},{"name":"Total carbon content"},{"name":"范围","range":"(7,5 - 70,0) %"}],"search_zh":"总碳含量 高温燃烧红外检测法 范围 范围 PN-EN ISO 21663:2021-06","technique_zh":"高温燃烧红外检测法"},{"_id":"6a8369ecaf14b9c0e7b1dc6d","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwa wtórne, Solid fuels: solid recovered fuels","methodology":"Zawartość wodoru","parameters":[{"name":"Zakres","range":"(0,90 - 9,80) %"},{"name":"Hydrogen content"},{"name":"Range","range":"(0,90 - 9,80) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR","High-temperature combustion method with IR detection"],"computed":[],"activity":"Zawartość wodoru\nZakres:\nZakres (0,90 - 9,80) %\nHydrogen content\nRange (0,90 - 9,80) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN ISO 21663:2021-06","norm_bases":["PN-EN ISO 21663:2021-06"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: stałe paliwa wtórne, Solid fuels: solid recovered fuels Zawartość wodoru\nZakres:\nZakres (0,90 - 9,80) %\nHydrogen content\nRange (0,90 - 9,80) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN ISO 21663:2021-06 Paliwa stale: stale paliwa wtorne, Solid fuels: solid recovered fuels Zawartosc wodoru\nZakres:\nZakres (0,90 - 9,80) %\nHydrogen content\nRange (0,90 - 9,80) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN ISO 21663:2021-06","categories":["petro"],"row_index":75,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrogen content","parameters_en":[{"name":"Range","range":"(0,90 - 9,80) %"},{"name":"Hydrogen content"},{"name":"Range","range":"(0,90 - 9,80) %"}],"search_en":"Hydrogen content High-temperature combustion with IR detection Range Range PN-EN ISO 21663:2021-06","technique_en":"High-temperature combustion with IR detection","parameters_zh":[{"name":"范围","range":"(0,90 - 9,80) %"},{"name":"Hydrogen content"},{"name":"范围","range":"(0,90 - 9,80) %"}],"search_zh":"氢含量 高温燃烧红外检测法 范围 范围 PN-EN ISO 21663:2021-06","technique_zh":"高温燃烧红外检测法","methodology_zh":"氢含量"},{"_id":"6a8369ecaf14b9c0e7b1dc6e","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Odpady kod: 19 01 11, 19 01 12, 19 05 03, 19 05 99, 19 06 04, 19 08 01, 19 08 02, 19 08 05, 19 09 01, 19 09 02, 19 12 09, 19 12 10, 19 12 11*, 19 12 12, 20 01 99, 20 02 03, 20 03 03, 20 03 06, 20 03 07, 20 03 99","methodology":"Zawartość wilgoci w próbce analitycznej","parameters":[{"name":"Zakres","range":"(0,1 - 4,9) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (0,1 - 4,9) %\nMetoda wagowa","reference":"PN-EN ISO 21660-3:2021-08","norm_bases":["PN-EN ISO 21660-3:2021-08"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":"Kody odpadów podane według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 19 01 11, 19 01 12, 19 05 03, 19 05 99, 19 06 04, 19 08 01, 19 08 02, 19 08 05, 19 09 01, 19 09 02, 19 12 09, 19 12 10, 19 12 11*, 19 12 12, 20 01 99, 20 02 03, 20 03 03, 20 03 06, 20 03 07, 20 03 99 Zawartość wilgoci w próbce analitycznej\nZakres (0,1 - 4,9) %\nMetoda wagowa PN-EN ISO 21660-3:2021-08 Odpady kod: 19 01 11, 19 01 12, 19 05 03, 19 05 99, 19 06 04, 19 08 01, 19 08 02, 19 08 05, 19 09 01, 19 09 02, 19 12 09, 19 12 10, 19 12 11*, 19 12 12, 20 01 99, 20 02 03, 20 03 03, 20 03 06, 20 03 07, 20 03 99 Zawartosc wilgoci w probce analitycznej\nZakres (0,1 - 4,9) %\nMetoda wagowa PN-EN ISO 21660-3:2021-08","categories":["environment"],"row_index":76,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Moisture content in the analytical sample","parameters_en":[{"name":"Range","range":"(0,1 - 4,9) %"}],"search_en":"Waste code: 19 01 11, 19 01 12, 19 05 03, 19 05 99, 19 06 04, 19 08 01, 19 08 02, 19 08 05, 19 09 01, 19 09 02, 19 12 09, 19 12 10, 19 12 11*, 19 12 12, 20 01 99, 20 02 03, 20 03 03, 20 03 06, 20 03 07, 20 03 99 Moisture content in the analytical sample Gravimetric method Range PN-EN ISO 21660-3:2021-08","technique_en":"Gravimetric method","test_object_en":"Waste code: 19 01 11, 19 01 12, 19 05 03, 19 05 99, 19 06 04, 19 08 01, 19 08 02, 19 08 05, 19 09 01, 19 09 02, 19 12 09, 19 12 10, 19 12 11*, 19 12 12, 20 01 99, 20 02 03, 20 03 03, 20 03 06, 20 03 07, 20 03 99","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(0,1 - 4,9) %"}],"search_zh":"废物代码：19 01 11、19 01 12、19 05 03、19 05 99、19 06 04、19 08 01、19 08 02、19 08 05、19 09 01、19 09 02、19 12 09、19 12 10、19 12 11*、19 12 12、20 01 99、20 02 03、20 03 03、20 03 06、20 03 07、20 03 99 分析样品水分含量 重量法 范围 PN-EN ISO 21660-3:2021-08","technique_zh":"重量法","test_object_zh":"废物代码：19 01 11、19 01 12、19 05 03、19 05 99、19 06 04、19 08 01、19 08 02、19 08 05、19 09 01、19 09 02、19 12 09、19 12 10、19 12 11*、19 12 12、20 01 99、20 02 03、20 03 03、20 03 06、20 03 07、20 03 99"},{"_id":"6a8369ecaf14b9c0e7b1dc6f","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Odpady kod: 19 01 11, 19 01 12, 19 05 03, 19 05 99, 19 06 04, 19 08 01, 19 08 02, 19 08 05, 19 09 01, 19 09 02, 19 12 09, 19 12 10, 19 12 11*, 19 12 12, 20 01 99, 20 02 03, 20 03 03, 20 03 06, 20 03 07, 20 03 99","methodology":"Zawartość siarki całkowitej","parameters":[{"name":"Zakres","range":"(0,01 - 1,27) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość siarki całkowitej\nZakres (0,01 - 1,27) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04584:2001","norm_bases":["PN-G-04584:2001"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":"Kody odpadów podane według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 19 01 11, 19 01 12, 19 05 03, 19 05 99, 19 06 04, 19 08 01, 19 08 02, 19 08 05, 19 09 01, 19 09 02, 19 12 09, 19 12 10, 19 12 11*, 19 12 12, 20 01 99, 20 02 03, 20 03 03, 20 03 06, 20 03 07, 20 03 99 Zawartość siarki całkowitej\nZakres (0,01 - 1,27) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04584:2001 Odpady kod: 19 01 11, 19 01 12, 19 05 03, 19 05 99, 19 06 04, 19 08 01, 19 08 02, 19 08 05, 19 09 01, 19 09 02, 19 12 09, 19 12 10, 19 12 11*, 19 12 12, 20 01 99, 20 02 03, 20 03 03, 20 03 06, 20 03 07, 20 03 99 Zawartosc siarki calkowitej\nZakres (0,01 - 1,27) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04584:2001","categories":["environment"],"row_index":77,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total sulfur content","parameters_en":[{"name":"Range","range":"(0,01 - 1,27) %"}],"search_en":"Waste code: 19 01 11, 19 01 12, 19 05 03, 19 05 99, 19 06 04, 19 08 01, 19 08 02, 19 08 05, 19 09 01, 19 09 02, 19 12 09, 19 12 10, 19 12 11*, 19 12 12, 20 01 99, 20 02 03, 20 03 03, 20 03 06, 20 03 07, 20 03 99 Total sulfur content High-temperature combustion with IR detection Range PN-G-04584:2001","technique_en":"High-temperature combustion with IR detection","test_object_en":"Waste code: 19 01 11, 19 01 12, 19 05 03, 19 05 99, 19 06 04, 19 08 01, 19 08 02, 19 08 05, 19 09 01, 19 09 02, 19 12 09, 19 12 10, 19 12 11*, 19 12 12, 20 01 99, 20 02 03, 20 03 03, 20 03 06, 20 03 07, 20 03 99","methodology_zh":"全硫含量","parameters_zh":[{"name":"范围","range":"(0,01 - 1,27) %"}],"search_zh":"废物代码：19 01 11、19 01 12、19 05 03、19 05 99、19 06 04、19 08 01、19 08 02、19 08 05、19 09 01、19 09 02、19 12 09、19 12 10、19 12 11*、19 12 12、20 01 99、20 02 03、20 03 03、20 03 06、20 03 07、20 03 99 全硫含量 高温燃烧红外检测法 范围 PN-G-04584:2001","technique_zh":"高温燃烧红外检测法","test_object_zh":"废物代码：19 01 11、19 01 12、19 05 03、19 05 99、19 06 04、19 08 01、19 08 02、19 08 05、19 09 01、19 09 02、19 12 09、19 12 10、19 12 11*、19 12 12、20 01 99、20 02 03、20 03 03、20 03 06、20 03 07、20 03 99"},{"_id":"6a8369ecaf14b9c0e7b1dc70","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Odpady kod: 19 01 11, 19 01 12, 19 05 03, 19 05 99, 19 06 04, 19 08 01, 19 08 02, 19 08 05, 19 09 01, 19 09 02, 19 12 09, 19 12 10, 19 12 11*, 19 12 12, 20 01 99, 20 02 03, 20 03 03, 20 03 06, 20 03 07, 20 03 99","methodology":"Zawartość azotu","parameters":[{"name":"Zakres","range":"(0,02 - 7,52) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją TC","techniques":["Metoda wysokotemperaturowego spalania z detekcją TC"],"computed":[],"activity":"Zawartość azotu\nZakres (0,02 - 7,52) %\nMetoda wysokotemperaturowego spalania z detekcją TC","reference":"PN-EN ISO 21663:2021-06","norm_bases":["PN-EN ISO 21663:2021-06"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":"Kody odpadów podane według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 19 01 11, 19 01 12, 19 05 03, 19 05 99, 19 06 04, 19 08 01, 19 08 02, 19 08 05, 19 09 01, 19 09 02, 19 12 09, 19 12 10, 19 12 11*, 19 12 12, 20 01 99, 20 02 03, 20 03 03, 20 03 06, 20 03 07, 20 03 99 Zawartość azotu\nZakres (0,02 - 7,52) %\nMetoda wysokotemperaturowego spalania z detekcją TC PN-EN ISO 21663:2021-06 Odpady kod: 19 01 11, 19 01 12, 19 05 03, 19 05 99, 19 06 04, 19 08 01, 19 08 02, 19 08 05, 19 09 01, 19 09 02, 19 12 09, 19 12 10, 19 12 11*, 19 12 12, 20 01 99, 20 02 03, 20 03 03, 20 03 06, 20 03 07, 20 03 99 Zawartosc azotu\nZakres (0,02 - 7,52) %\nMetoda wysokotemperaturowego spalania z detekcja TC PN-EN ISO 21663:2021-06","categories":["environment"],"row_index":78,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrogen content","parameters_en":[{"name":"Range","range":"(0,02 - 7,52) %"}],"search_en":"Waste code: 19 01 11, 19 01 12, 19 05 03, 19 05 99, 19 06 04, 19 08 01, 19 08 02, 19 08 05, 19 09 01, 19 09 02, 19 12 09, 19 12 10, 19 12 11*, 19 12 12, 20 01 99, 20 02 03, 20 03 03, 20 03 06, 20 03 07, 20 03 99 Nitrogen content High-temperature combustion with TC detection Range PN-EN ISO 21663:2021-06","technique_en":"High-temperature combustion with TC detection","test_object_en":"Waste code: 19 01 11, 19 01 12, 19 05 03, 19 05 99, 19 06 04, 19 08 01, 19 08 02, 19 08 05, 19 09 01, 19 09 02, 19 12 09, 19 12 10, 19 12 11*, 19 12 12, 20 01 99, 20 02 03, 20 03 03, 20 03 06, 20 03 07, 20 03 99","methodology_zh":"氮含量","parameters_zh":[{"name":"范围","range":"(0,02 - 7,52) %"}],"search_zh":"废物代码：19 01 11、19 01 12、19 05 03、19 05 99、19 06 04、19 08 01、19 08 02、19 08 05、19 09 01、19 09 02、19 12 09、19 12 10、19 12 11*、19 12 12、20 01 99、20 02 03、20 03 03、20 03 06、20 03 07、20 03 99 氮含量 高温燃烧总碳检测法 范围 PN-EN ISO 21663:2021-06","technique_zh":"高温燃烧总碳检测法","test_object_zh":"废物代码：19 01 11、19 01 12、19 05 03、19 05 99、19 06 04、19 08 01、19 08 02、19 08 05、19 09 01、19 09 02、19 12 09、19 12 10、19 12 11*、19 12 12、20 01 99、20 02 03、20 03 03、20 03 06、20 03 07、20 03 99"},{"_id":"6a8369ecaf14b9c0e7b1dc71","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Odpady kod: 19 01 11, 19 01 12, 19 05 03, 19 05 99, 19 06 04, 19 08 01, 19 08 02, 19 08 05, 19 09 01, 19 09 02, 19 12 09, 19 12 10, 19 12 11*, 19 12 12, 20 01 99, 20 02 03, 20 03 03, 20 03 06, 20 03 07, 20 03 99","methodology":"Ciepło spalania","parameters":[{"name":"Zakres","range":"(81 - 23668) kJ/kg"}],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna"],"computed":[],"activity":"Ciepło spalania\nZakres (81 - 23668) kJ/kg\nMetoda kalorymetryczna","reference":"PN-EN ISO 21654:2021-12","norm_bases":["PN-EN ISO 21654:2021-12"],"lab_section":"Pracownia Paliw Stałych","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 roku w sprawie w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. z 2015, poz. 1277) - Rozporządzeniem Ministra Środowiska z dnia 28 grudnia 2011 roku w sprawie w sprawie podziemnych składowisk odpadów (Dz. U. z 2011 nr 298, poz. 1771) | Kody odpadów podane według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 19 01 11, 19 01 12, 19 05 03, 19 05 99, 19 06 04, 19 08 01, 19 08 02, 19 08 05, 19 09 01, 19 09 02, 19 12 09, 19 12 10, 19 12 11*, 19 12 12, 20 01 99, 20 02 03, 20 03 03, 20 03 06, 20 03 07, 20 03 99 Ciepło spalania\nZakres (81 - 23668) kJ/kg\nMetoda kalorymetryczna PN-EN ISO 21654:2021-12 Odpady kod: 19 01 11, 19 01 12, 19 05 03, 19 05 99, 19 06 04, 19 08 01, 19 08 02, 19 08 05, 19 09 01, 19 09 02, 19 12 09, 19 12 10, 19 12 11*, 19 12 12, 20 01 99, 20 02 03, 20 03 03, 20 03 06, 20 03 07, 20 03 99 Cieplo spalania\nZakres (81 - 23668) kJ/kg\nMetoda kalorymetryczna PN-EN ISO 21654:2021-12","categories":["environment"],"row_index":79,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gross calorific value","parameters_en":[{"name":"Range","range":"(81 - 23668) kJ/kg"}],"search_en":"Waste code: 19 01 11, 19 01 12, 19 05 03, 19 05 99, 19 06 04, 19 08 01, 19 08 02, 19 08 05, 19 09 01, 19 09 02, 19 12 09, 19 12 10, 19 12 11*, 19 12 12, 20 01 99, 20 02 03, 20 03 03, 20 03 06, 20 03 07, 20 03 99 Gross calorific value Calorimetric method Range PN-EN ISO 21654:2021-12","technique_en":"Calorimetric method","test_object_en":"Waste code: 19 01 11, 19 01 12, 19 05 03, 19 05 99, 19 06 04, 19 08 01, 19 08 02, 19 08 05, 19 09 01, 19 09 02, 19 12 09, 19 12 10, 19 12 11*, 19 12 12, 20 01 99, 20 02 03, 20 03 03, 20 03 06, 20 03 07, 20 03 99","methodology_zh":"高位发热量","parameters_zh":[{"name":"范围","range":"(81 - 23668) kJ/kg"}],"search_zh":"废物代码：19 01 11、19 01 12、19 05 03、19 05 99、19 06 04、19 08 01、19 08 02、19 08 05、19 09 01、19 09 02、19 12 09、19 12 10、19 12 11*、19 12 12、20 01 99、20 02 03、20 03 03、20 03 06、20 03 07、20 03 99 高位发热量 量热法 范围 PN-EN ISO 21654:2021-12","technique_zh":"量热法","test_object_zh":"废物代码：19 01 11、19 01 12、19 05 03、19 05 99、19 06 04、19 08 01、19 08 02、19 08 05、19 09 01、19 09 02、19 12 09、19 12 10、19 12 11*、19 12 12、20 01 99、20 02 03、20 03 03、20 03 06、20 03 07、20 03 99"},{"_id":"6a8369ecaf14b9c0e7b1dc72","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Ropa naftowa","methodology":"Gęstość w temp. 15 oC i 20 oC","parameters":[{"name":"Zakres","range":"(0,7900 - 0,8900) g/cm3"}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"computed":[],"activity":"Gęstość w temp. 15 oC i 20 oC\nZakres (0,7900 - 0,8900) g/cm3\nMetoda oscylacyjna","reference":"ASTM D 5002-22 | PN-EN ISO 12185:2024-08","norm_bases":["ASTM D 5002-22","PN-EN ISO 12185:2024-08"],"lab_section":"Pracownia Produktów Naftowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ropa naftowa Gęstość w temp. 15 oC i 20 oC\nZakres (0,7900 - 0,8900) g/cm3\nMetoda oscylacyjna ASTM D 5002-22 | PN-EN ISO 12185:2024-08 Ropa naftowa Gestosc w temp. 15 oC i 20 oC\nZakres (0,7900 - 0,8900) g/cm3\nMetoda oscylacyjna ASTM D 5002-22 | PN-EN ISO 12185:2024-08","categories":["petro"],"row_index":80,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Density at temp. 15 oC and 20 oC","parameters_en":[{"name":"Range","range":"(0,7900 - 0,8900) g/cm3"}],"search_en":"Crude oil Density at temp. 15 oC and 20 oC Oscillation method Range ASTM D 5002-22 | PN-EN ISO 12185:2024-08","technique_en":"Oscillation method","test_object_en":"Crude oil","parameters_zh":[{"name":"范围","range":"(0,7900 - 0,8900) g/cm3"}],"search_zh":"原油 振荡法 范围 ASTM D 5002-22 | PN-EN ISO 12185:2024-08","technique_zh":"振荡法","test_object_zh":"原油"},{"_id":"6a8369ecaf14b9c0e7b1dc73","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Ropa naftowa","methodology":"Zawartość wody","parameters":[{"name":"Zakres","range":"(0,020 – 1,000) % (m/m)"}],"technique":"Metoda miareczkowania potencjometrycznego","techniques":["Metoda miareczkowania potencjometrycznego"],"computed":[],"activity":"Zawartość wody\nZakres (0,020 – 1,000) % (m/m)\nMetoda miareczkowania potencjometrycznego","reference":"ASTM D 4377-00 (2011)","norm_bases":["ASTM D 4377-00 (2011)"],"lab_section":"Pracownia Produktów Naftowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ropa naftowa Zawartość wody\nZakres (0,020 – 1,000) % (m/m)\nMetoda miareczkowania potencjometrycznego ASTM D 4377-00 (2011) Ropa naftowa Zawartosc wody\nZakres (0,020 – 1,000) % (m/m)\nMetoda miareczkowania potencjometrycznego ASTM D 4377-00 (2011)","categories":["water","petro"],"row_index":81,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water content","parameters_en":[{"name":"Range","range":"(0,020 – 1,000) % (m/m)"}],"search_en":"Crude oil Water content Potentiometric titration method Range ASTM D 4377-00 (2011)","technique_en":"Potentiometric titration method","test_object_en":"Crude oil","methodology_zh":"水分含量","parameters_zh":[{"name":"范围","range":"(0,020 – 1,000) % (m/m)"}],"search_zh":"原油 水分含量 电位滴定法 范围 ASTM D 4377-00 (2011)","technique_zh":"电位滴定法","test_object_zh":"原油"},{"_id":"6a8369ecaf14b9c0e7b1dc74","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Ropa naftowa","methodology":"Zawartość wody","parameters":[{"name":"Zakres","range":"(0,02 – 1,20) % (m/m)"}],"technique":"Metoda miareczkowania kulometrycznego","techniques":["Metoda miareczkowania kulometrycznego"],"computed":[],"activity":"Zawartość wody\nZakres (0,02 – 1,20) % (m/m)\nMetoda miareczkowania kulometrycznego","reference":"ASTM D 4928-24 Metoda A","norm_bases":["ASTM D 4928-24 Metoda A"],"lab_section":"Pracownia Produktów Naftowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ropa naftowa Zawartość wody\nZakres (0,02 – 1,20) % (m/m)\nMetoda miareczkowania kulometrycznego ASTM D 4928-24 Metoda A Ropa naftowa Zawartosc wody\nZakres (0,02 – 1,20) % (m/m)\nMetoda miareczkowania kulometrycznego ASTM D 4928-24 Metoda A","categories":["water","petro"],"row_index":82,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water content","parameters_en":[{"name":"Range","range":"(0,02 – 1,20) % (m/m)"}],"search_en":"Crude oil Water content Coulometric titration method Range ASTM D 4928-24 Metoda A","technique_en":"Coulometric titration method","test_object_en":"Crude oil","methodology_zh":"水分含量","parameters_zh":[{"name":"范围","range":"(0,02 – 1,20) % (m/m)"}],"search_zh":"原油 水分含量 库仑滴定法 范围 ASTM D 4928-24 Metoda A","technique_zh":"库仑滴定法","test_object_zh":"原油"},{"_id":"6a8369ecaf14b9c0e7b1dc75","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Ropa naftowa","methodology":"Zawartość osadów","parameters":[{"name":"Zakres","range":"(0,01 - 0,03) % (m/m)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość osadów\nZakres (0,01 - 0,03) % (m/m)\nMetoda wagowa","reference":"ASTM D 473-22 | PN-EN ISO 3735:2001","norm_bases":["ASTM D 473-22","PN-EN ISO 3735:2001"],"lab_section":"Pracownia Produktów Naftowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ropa naftowa Zawartość osadów\nZakres (0,01 - 0,03) % (m/m)\nMetoda wagowa ASTM D 473-22 | PN-EN ISO 3735:2001 Ropa naftowa Zawartosc osadow\nZakres (0,01 - 0,03) % (m/m)\nMetoda wagowa ASTM D 473-22 | PN-EN ISO 3735:2001","categories":["water","petro"],"row_index":83,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sediment content","parameters_en":[{"name":"Range","range":"(0,01 - 0,03) % (m/m)"}],"search_en":"Crude oil Sediment content Gravimetric method Range ASTM D 473-22 | PN-EN ISO 3735:2001","technique_en":"Gravimetric method","test_object_en":"Crude oil","parameters_zh":[{"name":"范围","range":"(0,01 - 0,03) % (m/m)"}],"search_zh":"原油 重量法 范围 ASTM D 473-22 | PN-EN ISO 3735:2001","technique_zh":"重量法","test_object_zh":"原油"},{"_id":"6a8369ecaf14b9c0e7b1dc76","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Ropa naftowa","methodology":"Zawartość siarki","parameters":[{"name":"Zakres","range":"(0,100 - 2,50) % (m/m)"}],"technique":"Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii","techniques":["Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii"],"computed":[],"activity":"Zawartość siarki\nZakres (0,100 - 2,50) % (m/m)\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii","reference":"ASTM D 4294-24","norm_bases":["ASTM D 4294-24"],"lab_section":"Pracownia Produktów Naftowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ropa naftowa Zawartość siarki\nZakres (0,100 - 2,50) % (m/m)\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii ASTM D 4294-24 Ropa naftowa Zawartosc siarki\nZakres (0,100 - 2,50) % (m/m)\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersja energii ASTM D 4294-24","categories":["petro"],"row_index":84,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfur content","parameters_en":[{"name":"Range","range":"(0,100 - 2,50) % (m/m)"}],"search_en":"Crude oil Sulfur content Energy-dispersive X-ray fluorescence spectrometry Range ASTM D 4294-24","technique_en":"Energy-dispersive X-ray fluorescence spectrometry","test_object_en":"Crude oil","parameters_zh":[{"name":"范围","range":"(0,100 - 2,50) % (m/m)"}],"search_zh":"原油 硫含量 能量色散X射线荧光光谱法 范围 ASTM D 4294-24","methodology_zh":"硫含量","test_object_zh":"原油","technique_zh":"能量色散X射线荧光光谱法"},{"_id":"6a8369ecaf14b9c0e7b1dc77","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Ropa naftowa","methodology":"Zawartość siarki","parameters":[{"name":"Zakres","range":"(0,10 - 2,50) % (m/m)"}],"technique":"Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii","techniques":["Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii"],"computed":[],"activity":"Zawartość siarki\nZakres (0,10 - 2,50) % (m/m)\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii","reference":"PN-EN ISO 8754:2026-02","norm_bases":["PN-EN ISO 8754:2026-02"],"lab_section":"Pracownia Produktów Naftowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ropa naftowa Zawartość siarki\nZakres (0,10 - 2,50) % (m/m)\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii PN-EN ISO 8754:2026-02 Ropa naftowa Zawartosc siarki\nZakres (0,10 - 2,50) % (m/m)\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersja energii PN-EN ISO 8754:2026-02","categories":["petro"],"row_index":85,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfur content","parameters_en":[{"name":"Range","range":"(0,10 - 2,50) % (m/m)"}],"search_en":"Crude oil Sulfur content Energy-dispersive X-ray fluorescence spectrometry Range PN-EN ISO 8754:2026-02","technique_en":"Energy-dispersive X-ray fluorescence spectrometry","test_object_en":"Crude oil","parameters_zh":[{"name":"范围","range":"(0,10 - 2,50) % (m/m)"}],"search_zh":"原油 硫含量 能量色散X射线荧光光谱法 范围 PN-EN ISO 8754:2026-02","methodology_zh":"硫含量","test_object_zh":"原油","technique_zh":"能量色散X射线荧光光谱法"},{"_id":"6a8369ecaf14b9c0e7b1dc78","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Ropa naftowa","methodology":"Zawartość wody","parameters":[{"name":"Zakres","range":"(0,025 - 1,00) % (m/m)"}],"technique":"Metoda destylacyjna","techniques":["Metoda destylacyjna"],"computed":[],"activity":"Zawartość wody\nZakres (0,025 - 1,00) % (m/m)\nMetoda destylacyjna","reference":"ASTM D 4006-22","norm_bases":["ASTM D 4006-22"],"lab_section":"Pracownia Produktów Naftowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ropa naftowa Zawartość wody\nZakres (0,025 - 1,00) % (m/m)\nMetoda destylacyjna ASTM D 4006-22 Ropa naftowa Zawartosc wody\nZakres (0,025 - 1,00) % (m/m)\nMetoda destylacyjna ASTM D 4006-22","categories":["water","petro"],"row_index":86,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water content","parameters_en":[{"name":"Range","range":"(0,025 - 1,00) % (m/m)"}],"search_en":"Crude oil Water content Distillation method Range ASTM D 4006-22","technique_en":"Distillation method","test_object_en":"Crude oil","methodology_zh":"水分含量","parameters_zh":[{"name":"范围","range":"(0,025 - 1,00) % (m/m)"}],"search_zh":"原油 水分含量 蒸馏法 范围 ASTM D 4006-22","technique_zh":"蒸馏法","test_object_zh":"原油"},{"_id":"6a8369ecaf14b9c0e7b1dc79","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa ciekłe: paliwo żeglugowe","methodology":"Zawartość siarki","parameters":[{"name":"Zakres","range":"(0,030 - 2,50) % (m/m)"}],"technique":"Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii","techniques":["Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii"],"computed":[],"activity":"Zawartość siarki\nZakres (0,030 - 2,50) % (m/m)\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii","reference":"PN-EN ISO 8754:2026-02","norm_bases":["PN-EN ISO 8754:2026-02"],"lab_section":"Pracownia Produktów Naftowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: paliwo żeglugowe Zawartość siarki\nZakres (0,030 - 2,50) % (m/m)\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii PN-EN ISO 8754:2026-02 Paliwa ciekle: paliwo zeglugowe Zawartosc siarki\nZakres (0,030 - 2,50) % (m/m)\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersja energii PN-EN ISO 8754:2026-02","categories":["petro"],"row_index":87,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfur content","parameters_en":[{"name":"Range","range":"(0,030 - 2,50) % (m/m)"}],"search_en":"Liquid fuels: marine fuel Sulfur content Energy-dispersive X-ray fluorescence spectrometry Range PN-EN ISO 8754:2026-02","technique_en":"Energy-dispersive X-ray fluorescence spectrometry","test_object_en":"Liquid fuels: marine fuel","parameters_zh":[{"name":"范围","range":"(0,030 - 2,50) % (m/m)"}],"search_zh":"硫含量 能量色散X射线荧光光谱法 范围 PN-EN ISO 8754:2026-02","methodology_zh":"硫含量","technique_zh":"能量色散X射线荧光光谱法"},{"_id":"6a8369ecaf14b9c0e7b1dc7a","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, paliwo do turbinowych silników lotniczych","methodology":"Gęstość w temp. 15 oC","parameters":[{"name":"Zakres","range":"(0,7200 - 0,8600) g/cm3"}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"computed":[],"activity":"Gęstość w temp. 15 oC\nZakres (0,7200 - 0,8600) g/cm3\nMetoda oscylacyjna","reference":"ASTM D 4052-22 | PN-EN ISO 12185:2024-08","norm_bases":["ASTM D 4052-22","PN-EN ISO 12185:2024-08"],"lab_section":"Pracownia Produktów Naftowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, benzyna bezołowiowa, paliwo do turbinowych silników lotniczych Gęstość w temp. 15 oC\nZakres (0,7200 - 0,8600) g/cm3\nMetoda oscylacyjna ASTM D 4052-22 | PN-EN ISO 12185:2024-08 Paliwa ciekle: olej napedowy, benzyna bezolowiowa, paliwo do turbinowych silnikow lotniczych Gestosc w temp. 15 oC\nZakres (0,7200 - 0,8600) g/cm3\nMetoda oscylacyjna ASTM D 4052-22 | PN-EN ISO 12185:2024-08","categories":["petro"],"row_index":88,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Density at 15 oC","parameters_en":[{"name":"Range","range":"(0,7200 - 0,8600) g/cm3"}],"search_en":"Liquid fuels: diesel fuel, unleaded petrol, aviation turbine fuel Density at 15 oC Oscillation method Range ASTM D 4052-22 | PN-EN ISO 12185:2024-08","technique_en":"Oscillation method","test_object_en":"Liquid fuels: diesel fuel, unleaded petrol, aviation turbine fuel","parameters_zh":[{"name":"范围","range":"(0,7200 - 0,8600) g/cm3"}],"search_zh":"振荡法 范围 ASTM D 4052-22 | PN-EN ISO 12185:2024-08","technique_zh":"振荡法"},{"_id":"6a8369ecaf14b9c0e7b1dc7b","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy","methodology":"Zawartość wody","parameters":[{"name":"Zakres","range":"(0,003 - 0,100) % (m/m)"}],"technique":"Metoda miareczkowania kulometrycznego","techniques":["Metoda miareczkowania kulometrycznego"],"computed":[],"activity":"Zawartość wody\nZakres (0,003 - 0,100) % (m/m)\nMetoda miareczkowania kulometrycznego","reference":"PN-EN ISO 12937:2005+Ap1:2021-11 | ASTM D 6304-25","norm_bases":["PN-EN ISO 12937:2005+Ap1:2021-11","ASTM D 6304-25"],"lab_section":"Pracownia Produktów Naftowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy Zawartość wody\nZakres (0,003 - 0,100) % (m/m)\nMetoda miareczkowania kulometrycznego PN-EN ISO 12937:2005+Ap1:2021-11 | ASTM D 6304-25 Paliwa ciekle: olej napedowy Zawartosc wody\nZakres (0,003 - 0,100) % (m/m)\nMetoda miareczkowania kulometrycznego PN-EN ISO 12937:2005+Ap1:2021-11 | ASTM D 6304-25","categories":["petro","water"],"row_index":89,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water content","parameters_en":[{"name":"Range","range":"(0,003 - 0,100) % (m/m)"}],"search_en":"Liquid fuels: diesel fuel Water content Coulometric titration method Range PN-EN ISO 12937:2005+Ap1:2021-11 | ASTM D 6304-25","technique_en":"Coulometric titration method","test_object_en":"Liquid fuels: diesel fuel","methodology_zh":"水分含量","parameters_zh":[{"name":"范围","range":"(0,003 - 0,100) % (m/m)"}],"search_zh":"液体燃料：柴油 水分含量 库仑滴定法 范围 PN-EN ISO 12937:2005+Ap1:2021-11 | ASTM D 6304-25","technique_zh":"库仑滴定法","test_object_zh":"液体燃料：柴油"},{"_id":"6a8369ecaf14b9c0e7b1dc7c","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy","methodology":"Skład frakcyjny","parameters":[{"name":"Zakres","range":"(150,0 - 370,0) °C"}],"technique":"Metoda destylacyjna","techniques":["Metoda destylacyjna"],"computed":[],"activity":"Skład frakcyjny\nZakres (150,0 - 370,0) °C\nMetoda destylacyjna","reference":"ASTM D 86-23ae2 | PN-EN ISO 3405:2019-05","norm_bases":["ASTM D 86-23ae2","PN-EN ISO 3405:2019-05"],"lab_section":"Pracownia Produktów Naftowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy Skład frakcyjny\nZakres (150,0 - 370,0) °C\nMetoda destylacyjna ASTM D 86-23ae2 | PN-EN ISO 3405:2019-05 Paliwa ciekle: olej napedowy Sklad frakcyjny\nZakres (150,0 - 370,0) °C\nMetoda destylacyjna ASTM D 86-23ae2 | PN-EN ISO 3405:2019-05","categories":["petro"],"row_index":90,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fractional composition","parameters_en":[{"name":"Range","range":"(150,0 - 370,0) °C"}],"search_en":"Liquid fuels: diesel fuel Fractional composition Distillation method Range ASTM D 86-23ae2 | PN-EN ISO 3405:2019-05","technique_en":"Distillation method","test_object_en":"Liquid fuels: diesel fuel","parameters_zh":[{"name":"范围","range":"(150,0 - 370,0) °C"}],"search_zh":"液体燃料：柴油 馏程组成 蒸馏法 范围 ASTM D 86-23ae2 | PN-EN ISO 3405:2019-05","technique_zh":"蒸馏法","test_object_zh":"液体燃料：柴油","methodology_zh":"馏程组成"},{"_id":"6a8369ecaf14b9c0e7b1dc7d","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy","methodology":"Temperatura zapłonu","parameters":[{"name":"Zakres","range":"(40,0 - 108,0) °C"}],"technique":"Metoda Pensky’ego-Martensa","techniques":["Metoda Pensky’ego-Martensa"],"computed":[],"activity":"Temperatura zapłonu\nZakres (40,0 - 108,0) °C\nMetoda Pensky’ego-Martensa","reference":"ASTM D 93-25 Metoda A | PN-EN ISO 2719:2016-08 +A1:2021-06 Metoda A","norm_bases":["ASTM D 93-25 Metoda A","PN-EN ISO 2719:2016-08 +A1:2021-06 Metoda A"],"lab_section":"Pracownia Produktów Naftowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy Temperatura zapłonu\nZakres (40,0 - 108,0) °C\nMetoda Pensky’ego-Martensa ASTM D 93-25 Metoda A | PN-EN ISO 2719:2016-08 +A1:2021-06 Metoda A Paliwa ciekle: olej napedowy Temperatura zaplonu\nZakres (40,0 - 108,0) °C\nMetoda Pensky’ego-Martensa ASTM D 93-25 Metoda A | PN-EN ISO 2719:2016-08 +A1:2021-06 Metoda A","categories":["petro"],"row_index":91,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Flash point","parameters_en":[{"name":"Range","range":"(40,0 - 108,0) °C"}],"search_en":"Liquid fuels: diesel fuel Flash point Pensky-Martens method Range ASTM D 93-25 Metoda A | PN-EN ISO 2719:2016-08 +A1:2021-06 Metoda A","technique_en":"Pensky-Martens method","test_object_en":"Liquid fuels: diesel fuel","parameters_zh":[{"name":"范围","range":"(40,0 - 108,0) °C"}],"search_zh":"液体燃料：柴油 闪点 范围 ASTM D 93-25 Metoda A | PN-EN ISO 2719:2016-08 +A1:2021-06 Metoda A","methodology_zh":"闪点","test_object_zh":"液体燃料：柴油"},{"_id":"6a8369ecaf14b9c0e7b1dc7e","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy","methodology":"Indeks cetanowy (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Indeks cetanowy (z obliczeń)","reference":"PN-EN ISO 4264:2018-08 | ASTM D 4737-21","norm_bases":["PN-EN ISO 4264:2018-08","ASTM D 4737-21"],"lab_section":"Pracownia Produktów Naftowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy Indeks cetanowy (z obliczeń) PN-EN ISO 4264:2018-08 | ASTM D 4737-21 Paliwa ciekle: olej napedowy Indeks cetanowy (z obliczen) PN-EN ISO 4264:2018-08 | ASTM D 4737-21","categories":["petro"],"row_index":92,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Cetane index (calculated)","search_en":"Liquid fuels: diesel fuel Cetane index (calculated) PN-EN ISO 4264:2018-08 | ASTM D 4737-21","test_object_en":"Liquid fuels: diesel fuel","search_zh":"液体燃料：柴油 十六烷指数（计算值） PN-EN ISO 4264:2018-08 | ASTM D 4737-21","test_object_zh":"液体燃料：柴油","methodology_zh":"十六烷指数（计算值）"},{"_id":"6a8369ecaf14b9c0e7b1dc7f","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy","methodology":"Zawartość siarki","parameters":[{"name":"Zakres","range":"(3,0 - 50,0) mg/kg"}],"technique":"Metoda fluorescencji w nadfiolecie","techniques":["Metoda fluorescencji w nadfiolecie"],"computed":[],"activity":"Zawartość siarki\nZakres (3,0 - 50,0) mg/kg\nMetoda fluorescencji w nadfiolecie","reference":"PN-EN ISO 20846:2020-03","norm_bases":["PN-EN ISO 20846:2020-03"],"lab_section":"Pracownia Produktów Naftowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy Zawartość siarki\nZakres (3,0 - 50,0) mg/kg\nMetoda fluorescencji w nadfiolecie PN-EN ISO 20846:2020-03 Paliwa ciekle: olej napedowy Zawartosc siarki\nZakres (3,0 - 50,0) mg/kg\nMetoda fluorescencji w nadfiolecie PN-EN ISO 20846:2020-03","categories":["petro"],"row_index":93,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfur content","parameters_en":[{"name":"Range","range":"(3,0 - 50,0) mg/kg"}],"search_en":"Liquid fuels: diesel fuel Sulfur content Ultraviolet fluorescence method Range PN-EN ISO 20846:2020-03","technique_en":"Ultraviolet fluorescence method","test_object_en":"Liquid fuels: diesel fuel","parameters_zh":[{"name":"范围","range":"(3,0 - 50,0) mg/kg"}],"search_zh":"液体燃料：柴油 硫含量 紫外荧光法 范围 PN-EN ISO 20846:2020-03","methodology_zh":"硫含量","test_object_zh":"液体燃料：柴油","technique_zh":"紫外荧光法"},{"_id":"6a8369ecaf14b9c0e7b1dc80","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Skład frakcyjny","parameters":[{"name":"Zakres","range":"(25,0 - 190,0) °C"}],"technique":"Metoda destylacyjna","techniques":["Metoda destylacyjna"],"computed":[],"activity":"Skład frakcyjny\nZakres (25,0 - 190,0) °C\nMetoda destylacyjna","reference":"ASTM D 86-23ae2 | PN-EN ISO 3405:2019-05","norm_bases":["ASTM D 86-23ae2","PN-EN ISO 3405:2019-05"],"lab_section":"Pracownia Produktów Naftowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Skład frakcyjny\nZakres (25,0 - 190,0) °C\nMetoda destylacyjna ASTM D 86-23ae2 | PN-EN ISO 3405:2019-05 Paliwa ciekle: benzyna bezolowiowa Sklad frakcyjny\nZakres (25,0 - 190,0) °C\nMetoda destylacyjna ASTM D 86-23ae2 | PN-EN ISO 3405:2019-05","categories":["petro"],"row_index":94,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fractional composition","parameters_en":[{"name":"Range","range":"(25,0 - 190,0) °C"}],"search_en":"Liquid fuels: unleaded petrol Fractional composition Distillation method Range ASTM D 86-23ae2 | PN-EN ISO 3405:2019-05","technique_en":"Distillation method","test_object_en":"Liquid fuels: unleaded petrol","parameters_zh":[{"name":"范围","range":"(25,0 - 190,0) °C"}],"search_zh":"液体燃料：无铅汽油 馏程组成 蒸馏法 范围 ASTM D 86-23ae2 | PN-EN ISO 3405:2019-05","technique_zh":"蒸馏法","methodology_zh":"馏程组成","test_object_zh":"液体燃料：无铅汽油"},{"_id":"6a8369ecaf14b9c0e7b1dc81","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Prężność par (DVPE)","parameters":[{"name":"Zakres","range":"(55,0 - 105,0) kPa"}],"technique":"Metoda mini Reid","techniques":["Metoda mini Reid"],"computed":[],"activity":"Prężność par (DVPE)\nZakres (55,0 - 105,0) kPa\nMetoda mini Reid","reference":"PN-EN 13016-1:2024-11 | ASTM D 5191-22","norm_bases":["PN-EN 13016-1:2024-11","ASTM D 5191-22"],"lab_section":"Pracownia Produktów Naftowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Prężność par (DVPE)\nZakres (55,0 - 105,0) kPa\nMetoda mini Reid PN-EN 13016-1:2024-11 | ASTM D 5191-22 Paliwa ciekle: benzyna bezolowiowa Preznosc par (DVPE)\nZakres (55,0 - 105,0) kPa\nMetoda mini Reid PN-EN 13016-1:2024-11 | ASTM D 5191-22","categories":["petro"],"row_index":95,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Vapour pressure (DVPE)","parameters_en":[{"name":"Range","range":"(55,0 - 105,0) kPa"}],"search_en":"Liquid fuels: unleaded petrol Vapour pressure (DVPE) Mini Reid method Range PN-EN 13016-1:2024-11 | ASTM D 5191-22","technique_en":"Mini Reid method","test_object_en":"Liquid fuels: unleaded petrol","parameters_zh":[{"name":"范围","range":"(55,0 - 105,0) kPa"}],"search_zh":"液体燃料：无铅汽油 迷你雷德法 范围 PN-EN 13016-1:2024-11 | ASTM D 5191-22","test_object_zh":"液体燃料：无铅汽油","technique_zh":"迷你雷德法"},{"_id":"6a8369ecaf14b9c0e7b1dc82","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Indeks lotności (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Indeks lotności (z obliczeń)","reference":"PN-EN 228:2026-01+Ap1:2026-02 Tablica 3 i 4","norm_bases":["PN-EN 228:2026-01+Ap1:2026-02 Tablica 3 i 4"],"lab_section":"Pracownia Produktów Naftowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Indeks lotności (z obliczeń) PN-EN 228:2026-01+Ap1:2026-02 Tablica 3 i 4 Paliwa ciekle: benzyna bezolowiowa Indeks lotnosci (z obliczen) PN-EN 228:2026-01+Ap1:2026-02 Tablica 3 i 4","categories":["petro"],"row_index":96,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Volatility index (calculated)","search_en":"Liquid fuels: unleaded petrol Volatility index (calculated) PN-EN 228:2026-01+Ap1:2026-02 Tablica 3 i 4","test_object_en":"Liquid fuels: unleaded petrol","search_zh":"液体燃料：无铅汽油 挥发性指数（计算值） PN-EN 228:2026-01+Ap1:2026-02 Tablica 3 i 4","test_object_zh":"液体燃料：无铅汽油","methodology_zh":"挥发性指数（计算值）"},{"_id":"6a8369ecaf14b9c0e7b1dc83","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa ciekłe: benzyna bezołowiowa","methodology":"Zawartość siarki","parameters":[{"name":"Zakres","range":"(3,0 - 50,0) mg/kg"}],"technique":"Metoda fluorescencji w nadfiolecie","techniques":["Metoda fluorescencji w nadfiolecie"],"computed":[],"activity":"Zawartość siarki\nZakres (3,0 - 50,0) mg/kg\nMetoda fluorescencji w nadfiolecie","reference":"PN -EN ISO 20846:2020-03","norm_bases":["PN -EN ISO 20846:2020-03"],"lab_section":"Pracownia Produktów Naftowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: benzyna bezołowiowa Zawartość siarki\nZakres (3,0 - 50,0) mg/kg\nMetoda fluorescencji w nadfiolecie PN -EN ISO 20846:2020-03 Paliwa ciekle: benzyna bezolowiowa Zawartosc siarki\nZakres (3,0 - 50,0) mg/kg\nMetoda fluorescencji w nadfiolecie PN -EN ISO 20846:2020-03","categories":["petro"],"row_index":97,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfur content","parameters_en":[{"name":"Range","range":"(3,0 - 50,0) mg/kg"}],"search_en":"Liquid fuels: unleaded petrol Sulfur content Ultraviolet fluorescence method Range PN -EN ISO 20846:2020-03","technique_en":"Ultraviolet fluorescence method","test_object_en":"Liquid fuels: unleaded petrol","parameters_zh":[{"name":"范围","range":"(3,0 - 50,0) mg/kg"}],"search_zh":"液体燃料：无铅汽油 硫含量 紫外荧光法 范围 PN -EN ISO 20846:2020-03","methodology_zh":"硫含量","technique_zh":"紫外荧光法","test_object_zh":"液体燃料：无铅汽油"},{"_id":"6a8369ecaf14b9c0e7b1dc84","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych","methodology":"Temperatura zapłonu","parameters":[{"name":"Zakres","range":"(38,0 - 65,0) °C"}],"technique":"Metoda zamkniętego tygla TAG","techniques":["Metoda zamkniętego tygla TAG"],"computed":[],"activity":"Temperatura zapłonu\nZakres (38,0 - 65,0) °C\nMetoda zamkniętego tygla TAG","reference":"ASTM D 56-22","norm_bases":["ASTM D 56-22"],"lab_section":"Pracownia Produktów Naftowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych Temperatura zapłonu\nZakres (38,0 - 65,0) °C\nMetoda zamkniętego tygla TAG ASTM D 56-22 Paliwa ciekle: paliwo do turbinowych silnikow lotniczych Temperatura zaplonu\nZakres (38,0 - 65,0) °C\nMetoda zamknietego tygla TAG ASTM D 56-22","categories":["petro"],"row_index":98,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Flash point","parameters_en":[{"name":"Range","range":"(38,0 - 65,0) °C"}],"search_en":"Liquid fuels: aviation turbine fuel Flash point TAG closed cup method Range ASTM D 56-22","technique_en":"TAG closed cup method","test_object_en":"Liquid fuels: aviation turbine fuel","parameters_zh":[{"name":"范围","range":"(38,0 - 65,0) °C"}],"search_zh":"液体燃料：航空涡轮发动机燃料 闪点 范围 ASTM D 56-22","methodology_zh":"闪点","test_object_zh":"液体燃料：航空涡轮发动机燃料"},{"_id":"6a8369ecaf14b9c0e7b1dc85","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych","methodology":"Skład frakcyjny","parameters":[{"name":"Zakres","range":"(140,0 - 300,0) °C"}],"technique":"Metoda destylacyjna","techniques":["Metoda destylacyjna"],"computed":[],"activity":"Skład frakcyjny\nZakres (140,0 - 300,0) °C\nMetoda destylacyjna","reference":"ASTM D 86-23ae2","norm_bases":["ASTM D 86-23ae2"],"lab_section":"Pracownia Produktów Naftowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych Skład frakcyjny\nZakres (140,0 - 300,0) °C\nMetoda destylacyjna ASTM D 86-23ae2 Paliwa ciekle: paliwo do turbinowych silnikow lotniczych Sklad frakcyjny\nZakres (140,0 - 300,0) °C\nMetoda destylacyjna ASTM D 86-23ae2","categories":["petro"],"row_index":99,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fractional composition","parameters_en":[{"name":"Range","range":"(140,0 - 300,0) °C"}],"search_en":"Liquid fuels: aviation turbine fuel Fractional composition Distillation method Range ASTM D 86-23ae2","technique_en":"Distillation method","test_object_en":"Liquid fuels: aviation turbine fuel","parameters_zh":[{"name":"范围","range":"(140,0 - 300,0) °C"}],"search_zh":"液体燃料：航空涡轮发动机燃料 馏程组成 蒸馏法 范围 ASTM D 86-23ae2","technique_zh":"蒸馏法","methodology_zh":"馏程组成","test_object_zh":"液体燃料：航空涡轮发动机燃料"},{"_id":"6a8369ecaf14b9c0e7b1dc86","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych","methodology":"Zawartość siarki","parameters":[{"name":"Zakres","range":"(0,05 - 0,3) % (m/m)"}],"technique":"Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii","techniques":["Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii"],"computed":[],"activity":"Zawartość siarki\nZakres (0,05 - 0,3) % (m/m)\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii","reference":"ASTM D 4294-24","norm_bases":["ASTM D 4294-24"],"lab_section":"Pracownia Produktów Naftowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: paliwo do turbinowych silników lotniczych Zawartość siarki\nZakres (0,05 - 0,3) % (m/m)\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii ASTM D 4294-24 Paliwa ciekle: paliwo do turbinowych silnikow lotniczych Zawartosc siarki\nZakres (0,05 - 0,3) % (m/m)\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersja energii ASTM D 4294-24","categories":["petro"],"row_index":100,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfur content","parameters_en":[{"name":"Range","range":"(0,05 - 0,3) % (m/m)"}],"search_en":"Liquid fuels: aviation turbine fuel Sulfur content Energy-dispersive X-ray fluorescence spectrometry Range ASTM D 4294-24","technique_en":"Energy-dispersive X-ray fluorescence spectrometry","test_object_en":"Liquid fuels: aviation turbine fuel","parameters_zh":[{"name":"范围","range":"(0,05 - 0,3) % (m/m)"}],"search_zh":"液体燃料：航空涡轮发动机燃料 硫含量 能量色散X射线荧光光谱法 范围 ASTM D 4294-24","methodology_zh":"硫含量","test_object_zh":"液体燃料：航空涡轮发动机燃料","technique_zh":"能量色散X射线荧光光谱法"},{"_id":"6a8369ecaf14b9c0e7b1dc87","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Materiały smarne: olej bazowy","methodology":"Gęstość w temp. 15 oC","parameters":[{"name":"Zakres","range":"(0,7500 - 0,9100) g/cm3"}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"computed":[],"activity":"Gęstość w temp. 15 oC\nZakres (0,7500 - 0,9100) g/cm3\nMetoda oscylacyjna","reference":"ASTM D 4052-22 | PN-EN ISO 12185:2024-08","norm_bases":["ASTM D 4052-22","PN-EN ISO 12185:2024-08"],"lab_section":"Pracownia Produktów Naftowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały smarne: olej bazowy Gęstość w temp. 15 oC\nZakres (0,7500 - 0,9100) g/cm3\nMetoda oscylacyjna ASTM D 4052-22 | PN-EN ISO 12185:2024-08 Materialy smarne: olej bazowy Gestosc w temp. 15 oC\nZakres (0,7500 - 0,9100) g/cm3\nMetoda oscylacyjna ASTM D 4052-22 | PN-EN ISO 12185:2024-08","categories":["materials","petro"],"row_index":101,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Density at 15 oC","parameters_en":[{"name":"Range","range":"(0,7500 - 0,9100) g/cm3"}],"search_en":"Lubricants: base oil Density at 15 oC Oscillation method Range ASTM D 4052-22 | PN-EN ISO 12185:2024-08","technique_en":"Oscillation method","test_object_en":"Lubricants: base oil","parameters_zh":[{"name":"范围","range":"(0,7500 - 0,9100) g/cm3"}],"search_zh":"振荡法 范围 ASTM D 4052-22 | PN-EN ISO 12185:2024-08","technique_zh":"振荡法"},{"_id":"6a8369ecaf14b9c0e7b1dc88","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Materiały smarne: olej bazowy","methodology":"Zawartość wody","parameters":[{"name":"Zakres","range":"(0,003 - 0,100) % (m/m)"}],"technique":"Metoda miareczkowania kulometrycznego","techniques":["Metoda miareczkowania kulometrycznego"],"computed":[],"activity":"Zawartość wody\nZakres (0,003 - 0,100) % (m/m)\nMetoda miareczkowania kulometrycznego","reference":"PN-EN ISO 12937:2005 | ASTM D 6304-25","norm_bases":["PN-EN ISO 12937:2005","ASTM D 6304-25"],"lab_section":"Pracownia Produktów Naftowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały smarne: olej bazowy Zawartość wody\nZakres (0,003 - 0,100) % (m/m)\nMetoda miareczkowania kulometrycznego PN-EN ISO 12937:2005 | ASTM D 6304-25 Materialy smarne: olej bazowy Zawartosc wody\nZakres (0,003 - 0,100) % (m/m)\nMetoda miareczkowania kulometrycznego PN-EN ISO 12937:2005 | ASTM D 6304-25","categories":["materials","petro","water"],"row_index":102,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water content","parameters_en":[{"name":"Range","range":"(0,003 - 0,100) % (m/m)"}],"search_en":"Lubricants: base oil Water content Coulometric titration method Range PN-EN ISO 12937:2005 | ASTM D 6304-25","technique_en":"Coulometric titration method","test_object_en":"Lubricants: base oil","methodology_zh":"水分含量","parameters_zh":[{"name":"范围","range":"(0,003 - 0,100) % (m/m)"}],"search_zh":"水分含量 库仑滴定法 范围 PN-EN ISO 12937:2005 | ASTM D 6304-25","technique_zh":"库仑滴定法"},{"_id":"6a8369ecaf14b9c0e7b1dc89","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Pasze, Kawa i herbata, przyprawy, oleje, tłuszcze zwierzęce i roślinne, zboża i przetwory zbożowe, żywność mrożona, wyroby garmażeryjne, koncentraty spożywcze, mięso i produkty mięsne, mleko i produkty mleczne, napoje bezalkoholowe (gazowane, niegazowane, soki, syropy), napoje alkoholowe i wyroby spirytusowe, owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-mięsne, ryby i przetwory rybne, słodycze i wyroby cukiernicze, suplementy diety, jaja i produkty jajeczne, Pieczywo i wyroby piekarnicze oraz wyroby i półprodukty ciastkarskie, Dodatki do żywności","methodology":"Liczba drobnoustrojów w temp. 30 °C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba drobnoustrojów w temp. 30 °C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 4833-1:2013-12+ A1:2022-06","norm_bases":["PN-EN ISO 4833-1:2013-12+ A1:2022-06"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pasze, Kawa i herbata, przyprawy, oleje, tłuszcze zwierzęce i roślinne, zboża i przetwory zbożowe, żywność mrożona, wyroby garmażeryjne, koncentraty spożywcze, mięso i produkty mięsne, mleko i produkty mleczne, napoje bezalkoholowe (gazowane, niegazowane, soki, syropy), napoje alkoholowe i wyroby spirytusowe, owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-mięsne, ryby i przetwory rybne, słodycze i wyroby cukiernicze, suplementy diety, jaja i produkty jajeczne, Pieczywo i wyroby piekarnicze oraz wyroby i półprodukty ciastkarskie, Dodatki do żywności Liczba drobnoustrojów w temp. 30 °C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 4833-1:2013-12+ A1:2022-06 Pasze, Kawa i herbata, przyprawy, oleje, tluszcze zwierzece i roslinne, zboza i przetwory zbozowe, zywnosc mrozona, wyroby garmazeryjne, koncentraty spozywcze, mieso i produkty miesne, mleko i produkty mleczne, napoje bezalkoholowe (gazowane, niegazowane, soki, syropy), napoje alkoholowe i wyroby spirytusowe, owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-miesne, ryby i przetwory rybne, slodycze i wyroby cukiernicze, suplementy diety, jaja i produkty jajeczne, Pieczywo i wyroby piekarnicze oraz wyroby i polprodukty ciastkarskie, Dodatki do zywnosci Liczba drobnoustrojow w temp. 30 °C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 4833-1:2013-12+ A1:2022-06","categories":["food","petro","microbiology","pharma"],"row_index":103,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Microorganism count at 30 °C","search_en":"Feed, Coffee and tea, spices, oils, animal and vegetable fats, cereals and cereal products, frozen food, delicatessen products, food concentrates, meat and meat products, milk and dairy products, non-alcoholic beverages (carbonated, still, juices, syrups), alcoholic beverages and spirit drinks, fruit and vegetables and fruit, vegetable and vegetable-meat products, fish and fish products, sweets and confectionery, food supplements, eggs and egg products, Bread and bakery products and pastry products and semi-finished pastry products, Food additives Microorganism count at 30 °C Plate method (pour plate) PN-EN ISO 4833-1:2013-12+ A1:2022-06","technique_en":"Plate method (pour plate)","test_object_en":"Feed, Coffee and tea, spices, oils, animal and vegetable fats, cereals and cereal products, frozen food, delicatessen products, food concentrates, meat and meat products, milk and dairy products, non-alcoholic beverages (carbonated, still, juices, syrups), alcoholic beverages and spirit drinks, fruit and vegetables and fruit, vegetable and vegetable-meat products, fish and fish products, sweets and confectionery, food supplements, eggs and egg products, Bread and bakery products and pastry products and semi-finished pastry products, Food additives","search_zh":"30 °C 微生物数 平板法（倾注培养） PN-EN ISO 4833-1:2013-12+ A1:2022-06","technique_zh":"平板法（倾注培养）","methodology_zh":"30 °C 微生物数"},{"_id":"6a8369ecaf14b9c0e7b1dc8a","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Pasze, Kawa i herbata, przyprawy, oleje, tłuszcze zwierzęce i roślinne, zboża i przetwory zbożowe, żywność mrożona, wyroby garmażeryjne, koncentraty spożywcze, mięso i produkty mięsne, mleko i produkty mleczne, napoje bezalkoholowe (gazowane, niegazowane, soki, syropy), napoje alkoholowe i wyroby spirytusowe, owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-mięsne, ryby i przetwory rybne, słodycze i wyroby cukiernicze, suplementy diety, jaja i produkty jajeczne, Pieczywo i wyroby piekarnicze oraz wyroby i półprodukty ciastkarskie","methodology":"Liczba β-glukuronidazo-dodatnich, Escherichia coli","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba β-glukuronidazo-dodatnich, Escherichia coli\nMetoda płytkowa (posiew wgłębny)","reference":"PN-ISO 16649-2:2004","norm_bases":["PN-ISO 16649-2:2004"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pasze, Kawa i herbata, przyprawy, oleje, tłuszcze zwierzęce i roślinne, zboża i przetwory zbożowe, żywność mrożona, wyroby garmażeryjne, koncentraty spożywcze, mięso i produkty mięsne, mleko i produkty mleczne, napoje bezalkoholowe (gazowane, niegazowane, soki, syropy), napoje alkoholowe i wyroby spirytusowe, owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-mięsne, ryby i przetwory rybne, słodycze i wyroby cukiernicze, suplementy diety, jaja i produkty jajeczne, Pieczywo i wyroby piekarnicze oraz wyroby i półprodukty ciastkarskie Liczba β-glukuronidazo-dodatnich, Escherichia coli\nMetoda płytkowa (posiew wgłębny) PN-ISO 16649-2:2004 Pasze, Kawa i herbata, przyprawy, oleje, tluszcze zwierzece i roslinne, zboza i przetwory zbozowe, zywnosc mrozona, wyroby garmazeryjne, koncentraty spozywcze, mieso i produkty miesne, mleko i produkty mleczne, napoje bezalkoholowe (gazowane, niegazowane, soki, syropy), napoje alkoholowe i wyroby spirytusowe, owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-miesne, ryby i przetwory rybne, slodycze i wyroby cukiernicze, suplementy diety, jaja i produkty jajeczne, Pieczywo i wyroby piekarnicze oraz wyroby i polprodukty ciastkarskie Liczba β-glukuronidazo-dodatnich, Escherichia coli\nMetoda plytkowa (posiew wglebny) PN-ISO 16649-2:2004","categories":["food","petro","microbiology","pharma"],"row_index":104,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Count of β-glucuronidase-positive, Escherichia coli","search_en":"Feed, Coffee and tea, spices, oils, animal and vegetable fats, cereals and cereal products, frozen food, delicatessen products, food concentrates, meat and meat products, milk and milk products, non-alcoholic beverages (carbonated, still, juices, syrups), alcoholic beverages and spirit drinks, fruit and vegetables and fruit and vegetable preserves and vegetable-meat preserves, fish and fish products, sweets and confectionery, food supplements, eggs and egg products, Bread and bakery products and confectionery products and semi-finished products Count of β-glucuronidase-positive, Escherichia coli Plate method (pour plate) PN-ISO 16649-2:2004","technique_en":"Plate method (pour plate)","test_object_en":"Feed, Coffee and tea, spices, oils, animal and vegetable fats, cereals and cereal products, frozen food, delicatessen products, food concentrates, meat and meat products, milk and milk products, non-alcoholic beverages (carbonated, still, juices, syrups), alcoholic beverages and spirit drinks, fruit and vegetables and fruit and vegetable preserves and vegetable-meat preserves, fish and fish products, sweets and confectionery, food supplements, eggs and egg products, Bread and bakery products and confectionery products and semi-finished products","search_zh":"β-葡萄糖醛酸酶阳性大肠埃希氏菌计数 平板法（倾注培养） PN-ISO 16649-2:2004","technique_zh":"平板法（倾注培养）","methodology_zh":"β-葡萄糖醛酸酶阳性大肠埃希氏菌计数"},{"_id":"6a8369ecaf14b9c0e7b1dc8b","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Pasze, Kawa i herbata, przyprawy, oleje, tłuszcze zwierzęce i roślinne, zboża i przetwory zbożowe, żywność mrożona, wyroby garmażeryjne, koncentraty spożywcze, mięso i produkty mięsne, mleko i produkty mleczne, napoje bezalkoholowe (gazowane, niegazowane, soki, syropy), napoje alkoholowe i wyroby spirytusowe, owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-mięsne, ryby i przetwory rybne, słodycze i wyroby cukiernicze, suplementy diety, jaja i produkty jajeczne, Pieczywo i wyroby piekarnicze oraz wyroby i półprodukty ciastkarskie","methodology":"Liczba gronkowców koagulazo-dodatnich (Staphylococcus aureus i innych gatunków)","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba gronkowców koagulazo-dodatnich (Staphylococcus aureus i innych gatunków)\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6888-2:2022-03 +A1:2024-02","norm_bases":["PN-EN ISO 6888-2:2022-03 +A1:2024-02"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pasze, Kawa i herbata, przyprawy, oleje, tłuszcze zwierzęce i roślinne, zboża i przetwory zbożowe, żywność mrożona, wyroby garmażeryjne, koncentraty spożywcze, mięso i produkty mięsne, mleko i produkty mleczne, napoje bezalkoholowe (gazowane, niegazowane, soki, syropy), napoje alkoholowe i wyroby spirytusowe, owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-mięsne, ryby i przetwory rybne, słodycze i wyroby cukiernicze, suplementy diety, jaja i produkty jajeczne, Pieczywo i wyroby piekarnicze oraz wyroby i półprodukty ciastkarskie Liczba gronkowców koagulazo-dodatnich (Staphylococcus aureus i innych gatunków)\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6888-2:2022-03 +A1:2024-02 Pasze, Kawa i herbata, przyprawy, oleje, tluszcze zwierzece i roslinne, zboza i przetwory zbozowe, zywnosc mrozona, wyroby garmazeryjne, koncentraty spozywcze, mieso i produkty miesne, mleko i produkty mleczne, napoje bezalkoholowe (gazowane, niegazowane, soki, syropy), napoje alkoholowe i wyroby spirytusowe, owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-miesne, ryby i przetwory rybne, slodycze i wyroby cukiernicze, suplementy diety, jaja i produkty jajeczne, Pieczywo i wyroby piekarnicze oraz wyroby i polprodukty ciastkarskie Liczba gronkowcow koagulazo-dodatnich (Staphylococcus aureus i innych gatunkow)\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6888-2:2022-03 +A1:2024-02","categories":["food","petro","pharma"],"row_index":105,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Coagulase-positive staphylococci count (Staphylococcus aureus and other species)","search_en":"Feed, Coffee and tea, spices, oils, animal and vegetable fats, cereals and cereal products, frozen food, delicatessen products, food concentrates, meat and meat products, milk and milk products, non-alcoholic beverages (carbonated, still, juices, syrups), alcoholic beverages and spirit drinks, fruit and vegetables and fruit and vegetable preserves and vegetable-meat preserves, fish and fish products, sweets and confectionery, food supplements, eggs and egg products, Bread and bakery products and confectionery products and semi-finished products Coagulase-positive staphylococci count (Staphylococcus aureus and other species) Plate method (pour plate) PN-EN ISO 6888-2:2022-03 +A1:2024-02","technique_en":"Plate method (pour plate)","test_object_en":"Feed, Coffee and tea, spices, oils, animal and vegetable fats, cereals and cereal products, frozen food, delicatessen products, food concentrates, meat and meat products, milk and milk products, non-alcoholic beverages (carbonated, still, juices, syrups), alcoholic beverages and spirit drinks, fruit and vegetables and fruit and vegetable preserves and vegetable-meat preserves, fish and fish products, sweets and confectionery, food supplements, eggs and egg products, Bread and bakery products and confectionery products and semi-finished products","search_zh":"凝固酶阳性葡萄球菌数（金黄色葡萄球菌及其他菌种） 平板法（倾注培养） PN-EN ISO 6888-2:2022-03 +A1:2024-02","technique_zh":"平板法（倾注培养）","methodology_zh":"凝固酶阳性葡萄球菌数（金黄色葡萄球菌及其他菌种）"},{"_id":"6a8369ecaf14b9c0e7b1dc8c","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Pasze, Kawa i herbata, przyprawy, oleje, tłuszcze zwierzęce i roślinne, zboża i przetwory zbożowe, żywność mrożona, wyroby garmażeryjne, koncentraty spożywcze, mięso i produkty mięsne, mleko i produkty mleczne, napoje bezalkoholowe (gazowane, niegazowane, soki, syropy), napoje alkoholowe i wyroby spirytusowe, owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-mięsne, ryby i przetwory rybne, słodycze i wyroby cukiernicze, suplementy diety, jaja i produkty jajeczne, Pieczywo i wyroby piekarnicze oraz wyroby i półprodukty ciastkarskie","methodology":"Liczba bakterii z grupy coli","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba bakterii z grupy coli\nMetoda płytkowa (posiew wgłębny)","reference":"PN-ISO 4832:2007","norm_bases":["PN-ISO 4832:2007"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pasze, Kawa i herbata, przyprawy, oleje, tłuszcze zwierzęce i roślinne, zboża i przetwory zbożowe, żywność mrożona, wyroby garmażeryjne, koncentraty spożywcze, mięso i produkty mięsne, mleko i produkty mleczne, napoje bezalkoholowe (gazowane, niegazowane, soki, syropy), napoje alkoholowe i wyroby spirytusowe, owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-mięsne, ryby i przetwory rybne, słodycze i wyroby cukiernicze, suplementy diety, jaja i produkty jajeczne, Pieczywo i wyroby piekarnicze oraz wyroby i półprodukty ciastkarskie Liczba bakterii z grupy coli\nMetoda płytkowa (posiew wgłębny) PN-ISO 4832:2007 Pasze, Kawa i herbata, przyprawy, oleje, tluszcze zwierzece i roslinne, zboza i przetwory zbozowe, zywnosc mrozona, wyroby garmazeryjne, koncentraty spozywcze, mieso i produkty miesne, mleko i produkty mleczne, napoje bezalkoholowe (gazowane, niegazowane, soki, syropy), napoje alkoholowe i wyroby spirytusowe, owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-miesne, ryby i przetwory rybne, slodycze i wyroby cukiernicze, suplementy diety, jaja i produkty jajeczne, Pieczywo i wyroby piekarnicze oraz wyroby i polprodukty ciastkarskie Liczba bakterii z grupy coli\nMetoda plytkowa (posiew wglebny) PN-ISO 4832:2007","categories":["food","petro","microbiology","pharma"],"row_index":106,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Coliform bacteria count","search_en":"Feed, Coffee and tea, spices, oils, animal and vegetable fats, cereals and cereal products, frozen food, delicatessen products, food concentrates, meat and meat products, milk and milk products, non-alcoholic beverages (carbonated, still, juices, syrups), alcoholic beverages and spirit drinks, fruit and vegetables and fruit and vegetable preserves and vegetable-meat preserves, fish and fish products, sweets and confectionery, food supplements, eggs and egg products, Bread and bakery products and confectionery products and semi-finished products Coliform bacteria count Plate method (pour plate) PN-ISO 4832:2007","technique_en":"Plate method (pour plate)","test_object_en":"Feed, Coffee and tea, spices, oils, animal and vegetable fats, cereals and cereal products, frozen food, delicatessen products, food concentrates, meat and meat products, milk and milk products, non-alcoholic beverages (carbonated, still, juices, syrups), alcoholic beverages and spirit drinks, fruit and vegetables and fruit and vegetable preserves and vegetable-meat preserves, fish and fish products, sweets and confectionery, food supplements, eggs and egg products, Bread and bakery products and confectionery products and semi-finished products","search_zh":"大肠菌群计数 平板法（倾注培养） PN-ISO 4832:2007","technique_zh":"平板法（倾注培养）","methodology_zh":"大肠菌群计数"},{"_id":"6a8369ecaf14b9c0e7b1dc8d","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Konserwy warzywno-mięsne, warzywne, owocowe, konserwy rybne, konserwy mięsne","methodology":"Trwałość konserw","parameters":[],"technique":"Metoda termostatowa","techniques":["Metoda termostatowa"],"computed":[],"activity":"Trwałość konserw\nMetoda termostatowa","reference":"PB-PAZ/M-03 wersja 01 z dnia 01.03.2021 r.","norm_bases":["PB-PAZ/M-03 wersja 01 z dnia 01.03.2021 r."],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Konserwy warzywno-mięsne, warzywne, owocowe, konserwy rybne, konserwy mięsne Trwałość konserw\nMetoda termostatowa PB-PAZ/M-03 wersja 01 z dnia 01.03.2021 r. Konserwy warzywno-miesne, warzywne, owocowe, konserwy rybne, konserwy miesne Trwalosc konserw\nMetoda termostatowa PB-PAZ/M-03 wersja 01 z dnia 01.03.2021 r.","categories":["other"],"row_index":107,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Shelf stability of canned products","search_en":"Canned vegetable-meat, vegetable and fruit products, canned fish, canned meat Shelf stability of canned products Thermostatic method PB-PAZ/M-03 wersja 01 z dnia 01.03.2021 r.","technique_en":"Thermostatic method","test_object_en":"Canned vegetable-meat, vegetable and fruit products, canned fish, canned meat","methodology_zh":"罐头保存性","search_zh":"罐头保存性 恒温培养法 PB-PAZ/M-03 wersja 01 z dnia 01.03.2021 r.","technique_zh":"恒温培养法"},{"_id":"6a8369ecaf14b9c0e7b1dc8e","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Opakowania hermetycznie zamknięte: pasze dla zwierząt, mleko i produkty mleczne","methodology":"Trwałość opakowań hermetycznie zamkniętych","parameters":[],"technique":"Metoda termostatowa","techniques":["Metoda termostatowa"],"computed":[],"activity":"Trwałość opakowań hermetycznie zamkniętych\nMetoda termostatowa","reference":"PB-PAZ/M-03 wersja 01 z dnia 01.03.2021 r.","norm_bases":["PB-PAZ/M-03 wersja 01 z dnia 01.03.2021 r."],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Opakowania hermetycznie zamknięte: pasze dla zwierząt, mleko i produkty mleczne Trwałość opakowań hermetycznie zamkniętych\nMetoda termostatowa PB-PAZ/M-03 wersja 01 z dnia 01.03.2021 r. Opakowania hermetycznie zamkniete: pasze dla zwierzat, mleko i produkty mleczne Trwalosc opakowan hermetycznie zamknietych\nMetoda termostatowa PB-PAZ/M-03 wersja 01 z dnia 01.03.2021 r.","categories":["food"],"row_index":108,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Integrity of hermetically sealed packaging","search_en":"Hermetically sealed packaging: animal feed, milk and dairy products Integrity of hermetically sealed packaging Thermostatic method PB-PAZ/M-03 wersja 01 z dnia 01.03.2021 r.","technique_en":"Thermostatic method","test_object_en":"Hermetically sealed packaging: animal feed, milk and dairy products","search_zh":"恒温培养法 PB-PAZ/M-03 wersja 01 z dnia 01.03.2021 r.","technique_zh":"恒温培养法"},{"_id":"6a8369ecaf14b9c0e7b1dc8f","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Pasze, kawa i herbata, przyprawy, oleje, tłuszcze zwierzęce i roślinne, zboża i przetwory zbożowe, żywność mrożona, wyroby garmażeryjne, koncentraty spożywcze, mięso i produkty mięsne, mleko i produkty mleczne, napoje bezalkoholowe (gazowane, niegazowane, soki, syropy), napoje alkoholowe i wyroby spirytusowe, owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-mięsne, ryby i przetwory rybne, słodycze i wyroby cukiernicze, suplementy diety, jaja i produkty jajeczne, dodatki do żywności, żywność dla dzieci, suplementy diety, cukier, pieczywo i wyroby piekarnicze, wyroby i półprodukty ciastkarskie","methodology":"Liczba Listeria monocytogenes","parameters":[],"technique":"Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda płytkowa (posiew powierzchniowy)"],"computed":[],"activity":"Liczba Listeria monocytogenes\nMetoda płytkowa (posiew powierzchniowy)","reference":"PN-EN ISO 11290-2:2017-07","norm_bases":["PN-EN ISO 11290-2:2017-07"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pasze, kawa i herbata, przyprawy, oleje, tłuszcze zwierzęce i roślinne, zboża i przetwory zbożowe, żywność mrożona, wyroby garmażeryjne, koncentraty spożywcze, mięso i produkty mięsne, mleko i produkty mleczne, napoje bezalkoholowe (gazowane, niegazowane, soki, syropy), napoje alkoholowe i wyroby spirytusowe, owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-mięsne, ryby i przetwory rybne, słodycze i wyroby cukiernicze, suplementy diety, jaja i produkty jajeczne, dodatki do żywności, żywność dla dzieci, suplementy diety, cukier, pieczywo i wyroby piekarnicze, wyroby i półprodukty ciastkarskie Liczba Listeria monocytogenes\nMetoda płytkowa (posiew powierzchniowy) PN-EN ISO 11290-2:2017-07 Pasze, kawa i herbata, przyprawy, oleje, tluszcze zwierzece i roslinne, zboza i przetwory zbozowe, zywnosc mrozona, wyroby garmazeryjne, koncentraty spozywcze, mieso i produkty miesne, mleko i produkty mleczne, napoje bezalkoholowe (gazowane, niegazowane, soki, syropy), napoje alkoholowe i wyroby spirytusowe, owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-miesne, ryby i przetwory rybne, slodycze i wyroby cukiernicze, suplementy diety, jaja i produkty jajeczne, dodatki do zywnosci, zywnosc dla dzieci, suplementy diety, cukier, pieczywo i wyroby piekarnicze, wyroby i polprodukty ciastkarskie Liczba Listeria monocytogenes\nMetoda plytkowa (posiew powierzchniowy) PN-EN ISO 11290-2:2017-07","categories":["food","petro","microbiology","pharma"],"row_index":109,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Listeria monocytogenes count","search_en":"Feed, coffee and tea, spices, oils, animal and vegetable fats, cereals and cereal products, frozen food, delicatessen products, food concentrates, meat and meat products, milk and milk products, non-alcoholic beverages (carbonated, still, juices, syrups), alcoholic beverages and spirit drinks, fruit and vegetables and fruit and vegetable preserves and vegetable-meat preserves, fish and fish products, sweets and confectionery, food supplements, eggs and egg products, food additives, food for children, food supplements, sugar, bread and bakery products, confectionery products and semi-finished products Listeria monocytogenes count Plate method (spread plate) PN-EN ISO 11290-2:2017-07","technique_en":"Plate method (spread plate)","test_object_en":"Feed, coffee and tea, spices, oils, animal and vegetable fats, cereals and cereal products, frozen food, delicatessen products, food concentrates, meat and meat products, milk and milk products, non-alcoholic beverages (carbonated, still, juices, syrups), alcoholic beverages and spirit drinks, fruit and vegetables and fruit and vegetable preserves and vegetable-meat preserves, fish and fish products, sweets and confectionery, food supplements, eggs and egg products, food additives, food for children, food supplements, sugar, bread and bakery products, confectionery products and semi-finished products","search_zh":"单核细胞增生李斯特氏菌计数 平板法（表面涂布） PN-EN ISO 11290-2:2017-07","technique_zh":"平板法（表面涂布）","methodology_zh":"单核细胞增生李斯特氏菌计数"},{"_id":"6a8369ecaf14b9c0e7b1dc90","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Pasze, kawa i herbata, przyprawy, oleje, tłuszcze zwierzęce i roślinne, zboża i przetwory zbożowe, żywność mrożona, wyroby garmażeryjne, koncentraty spożywcze, mięso i produkty mięsne, mleko i produkty mleczne, napoje bezalkoholowe (gazowane, niegazowane, soki, syropy), napoje alkoholowe i wyroby spirytusowe, owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-mięsne, ryby i przetwory rybne, słodycze i wyroby cukiernicze, suplementy diety, jaja i produkty jajeczne, dodatki do żywności, żywność dla dzieci, suplementy diety, cukier, pieczywo i wyroby piekarnicze, wyroby i półprodukty ciastkarskie","methodology":"Obecność Enterobacteriaceae","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność Enterobacteriaceae\nMetoda hodowlana z potwierdzeniem biochemicznym","reference":"PN-EN ISO 21528-1:2017-08","norm_bases":["PN-EN ISO 21528-1:2017-08"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pasze, kawa i herbata, przyprawy, oleje, tłuszcze zwierzęce i roślinne, zboża i przetwory zbożowe, żywność mrożona, wyroby garmażeryjne, koncentraty spożywcze, mięso i produkty mięsne, mleko i produkty mleczne, napoje bezalkoholowe (gazowane, niegazowane, soki, syropy), napoje alkoholowe i wyroby spirytusowe, owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-mięsne, ryby i przetwory rybne, słodycze i wyroby cukiernicze, suplementy diety, jaja i produkty jajeczne, dodatki do żywności, żywność dla dzieci, suplementy diety, cukier, pieczywo i wyroby piekarnicze, wyroby i półprodukty ciastkarskie Obecność Enterobacteriaceae\nMetoda hodowlana z potwierdzeniem biochemicznym PN-EN ISO 21528-1:2017-08 Pasze, kawa i herbata, przyprawy, oleje, tluszcze zwierzece i roslinne, zboza i przetwory zbozowe, zywnosc mrozona, wyroby garmazeryjne, koncentraty spozywcze, mieso i produkty miesne, mleko i produkty mleczne, napoje bezalkoholowe (gazowane, niegazowane, soki, syropy), napoje alkoholowe i wyroby spirytusowe, owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-miesne, ryby i przetwory rybne, slodycze i wyroby cukiernicze, suplementy diety, jaja i produkty jajeczne, dodatki do zywnosci, zywnosc dla dzieci, suplementy diety, cukier, pieczywo i wyroby piekarnicze, wyroby i polprodukty ciastkarskie Obecnosc Enterobacteriaceae\nMetoda hodowlana z potwierdzeniem biochemicznym PN-EN ISO 21528-1:2017-08","categories":["food","petro","pharma"],"row_index":110,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of Enterobacteriaceae","search_en":"Feed, coffee and tea, spices, oils, animal and vegetable fats, cereals and cereal products, frozen food, delicatessen products, food concentrates, meat and meat products, milk and milk products, non-alcoholic beverages (carbonated, still, juices, syrups), alcoholic beverages and spirit drinks, fruit and vegetables and fruit and vegetable preserves and vegetable-meat preserves, fish and fish products, sweets and confectionery, food supplements, eggs and egg products, food additives, food for children, food supplements, sugar, bread and bakery products, confectionery products and semi-finished products Presence of Enterobacteriaceae Culture method with biochemical confirmation PN-EN ISO 21528-1:2017-08","technique_en":"Culture method with biochemical confirmation","test_object_en":"Feed, coffee and tea, spices, oils, animal and vegetable fats, cereals and cereal products, frozen food, delicatessen products, food concentrates, meat and meat products, milk and milk products, non-alcoholic beverages (carbonated, still, juices, syrups), alcoholic beverages and spirit drinks, fruit and vegetables and fruit and vegetable preserves and vegetable-meat preserves, fish and fish products, sweets and confectionery, food supplements, eggs and egg products, food additives, food for children, food supplements, sugar, bread and bakery products, confectionery products and semi-finished products","search_zh":"肠杆菌科的检出 培养法结合生化确认 PN-EN ISO 21528-1:2017-08","technique_zh":"培养法结合生化确认","methodology_zh":"肠杆菌科的检出"},{"_id":"6a8369ecaf14b9c0e7b1dc91","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Pasze, kawa i herbata, przyprawy, oleje, tłuszcze zwierzęce i roślinne, zboża i przetwory zbożowe, żywność mrożona, wyroby garmażeryjne, koncentraty spożywcze, mięso i produkty mięsne, mleko i produkty mleczne, napoje bezalkoholowe (gazowane, niegazowane, soki, syropy), napoje alkoholowe i wyroby spirytusowe, owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-mięsne, ryby i przetwory rybne, słodycze i wyroby cukiernicze, suplementy diety, jaja i produkty jajeczne, dodatki do żywności, żywność dla dzieci, suplementy diety, cukier, pieczywo i wyroby piekarnicze, wyroby i półprodukty ciastkarskie","methodology":"Liczba Enterobacteriaceae","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba Enterobacteriaceae\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 21528-2:2017-08","norm_bases":["PN-EN ISO 21528-2:2017-08"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pasze, kawa i herbata, przyprawy, oleje, tłuszcze zwierzęce i roślinne, zboża i przetwory zbożowe, żywność mrożona, wyroby garmażeryjne, koncentraty spożywcze, mięso i produkty mięsne, mleko i produkty mleczne, napoje bezalkoholowe (gazowane, niegazowane, soki, syropy), napoje alkoholowe i wyroby spirytusowe, owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-mięsne, ryby i przetwory rybne, słodycze i wyroby cukiernicze, suplementy diety, jaja i produkty jajeczne, dodatki do żywności, żywność dla dzieci, suplementy diety, cukier, pieczywo i wyroby piekarnicze, wyroby i półprodukty ciastkarskie Liczba Enterobacteriaceae\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 21528-2:2017-08 Pasze, kawa i herbata, przyprawy, oleje, tluszcze zwierzece i roslinne, zboza i przetwory zbozowe, zywnosc mrozona, wyroby garmazeryjne, koncentraty spozywcze, mieso i produkty miesne, mleko i produkty mleczne, napoje bezalkoholowe (gazowane, niegazowane, soki, syropy), napoje alkoholowe i wyroby spirytusowe, owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-miesne, ryby i przetwory rybne, slodycze i wyroby cukiernicze, suplementy diety, jaja i produkty jajeczne, dodatki do zywnosci, zywnosc dla dzieci, suplementy diety, cukier, pieczywo i wyroby piekarnicze, wyroby i polprodukty ciastkarskie Liczba Enterobacteriaceae\nMetoda plytkowa (posiew wglebny) PN-EN ISO 21528-2:2017-08","categories":["food","petro","pharma"],"row_index":111,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Enterobacteriaceae count","search_en":"Feed, coffee and tea, spices, oils, animal and vegetable fats, cereals and cereal products, frozen food, delicatessen products, food concentrates, meat and meat products, milk and milk products, non-alcoholic beverages (carbonated, still, juices, syrups), alcoholic beverages and spirit drinks, fruit and vegetables and fruit and vegetable preserves and vegetable-meat preserves, fish and fish products, sweets and confectionery, food supplements, eggs and egg products, food additives, food for children, food supplements, sugar, bread and bakery products, confectionery products and semi-finished products Enterobacteriaceae count Plate method (pour plate) PN-EN ISO 21528-2:2017-08","technique_en":"Plate method (pour plate)","test_object_en":"Feed, coffee and tea, spices, oils, animal and vegetable fats, cereals and cereal products, frozen food, delicatessen products, food concentrates, meat and meat products, milk and milk products, non-alcoholic beverages (carbonated, still, juices, syrups), alcoholic beverages and spirit drinks, fruit and vegetables and fruit and vegetable preserves and vegetable-meat preserves, fish and fish products, sweets and confectionery, food supplements, eggs and egg products, food additives, food for children, food supplements, sugar, bread and bakery products, confectionery products and semi-finished products","methodology_zh":"肠杆菌科（Enterobacteriaceae）计数","search_zh":"肠杆菌科（Enterobacteriaceae）计数 平板法（倾注培养） PN-EN ISO 21528-2:2017-08","technique_zh":"平板法（倾注培养）"},{"_id":"6a8369ecaf14b9c0e7b1dc92","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Pasze, kawa i herbata, przyprawy, oleje, tłuszcze zwierzęce i roślinne, zboża i przetwory zbożowe, żywność mrożona, wyroby garmażeryjne, koncentraty spożywcze, mięso i produkty mięsne, mleko i produkty mleczne, napoje bezalkoholowe (gazowane, niegazowane, soki, syropy), napoje alkoholowe i wyroby spirytusowe, owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-mięsne, ryby i przetwory rybne, słodycze i wyroby cukiernicze, suplementy diety, jaja i produkty jajeczne, pieczywo i wyroby piekarnicze, wyroby i półprodukty ciastkarskie","methodology":"Obecność bakterii z grupy coli","parameters":[],"technique":"Metoda hodowlana, probówkowa","techniques":["Metoda hodowlana, probówkowa"],"computed":[],"activity":"Obecność bakterii z grupy coli\nMetoda hodowlana, probówkowa","reference":"PN-ISO 4831:2007","norm_bases":["PN-ISO 4831:2007"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pasze, kawa i herbata, przyprawy, oleje, tłuszcze zwierzęce i roślinne, zboża i przetwory zbożowe, żywność mrożona, wyroby garmażeryjne, koncentraty spożywcze, mięso i produkty mięsne, mleko i produkty mleczne, napoje bezalkoholowe (gazowane, niegazowane, soki, syropy), napoje alkoholowe i wyroby spirytusowe, owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-mięsne, ryby i przetwory rybne, słodycze i wyroby cukiernicze, suplementy diety, jaja i produkty jajeczne, pieczywo i wyroby piekarnicze, wyroby i półprodukty ciastkarskie Obecność bakterii z grupy coli\nMetoda hodowlana, probówkowa PN-ISO 4831:2007 Pasze, kawa i herbata, przyprawy, oleje, tluszcze zwierzece i roslinne, zboza i przetwory zbozowe, zywnosc mrozona, wyroby garmazeryjne, koncentraty spozywcze, mieso i produkty miesne, mleko i produkty mleczne, napoje bezalkoholowe (gazowane, niegazowane, soki, syropy), napoje alkoholowe i wyroby spirytusowe, owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-miesne, ryby i przetwory rybne, slodycze i wyroby cukiernicze, suplementy diety, jaja i produkty jajeczne, pieczywo i wyroby piekarnicze, wyroby i polprodukty ciastkarskie Obecnosc bakterii z grupy coli\nMetoda hodowlana, probowkowa PN-ISO 4831:2007","categories":["food","petro","microbiology","pharma"],"row_index":112,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of coliform bacteria","search_en":"Feed, coffee and tea, spices, oils, animal and vegetable fats, cereals and cereal products, frozen food, delicatessen products, food concentrates, meat and meat products, milk and milk products, non-alcoholic beverages (carbonated, still, juices, syrups), alcoholic beverages and spirit products, fruit and vegetables and fruit and vegetable products and vegetable-meat products, fish and fish products, sweets and confectionery products, food supplements, eggs and egg products, bread and bakery products, pastry products and semi-products Presence of coliform bacteria Culture method, tube PN-ISO 4831:2007","technique_en":"Culture method, tube","test_object_en":"Feed, coffee and tea, spices, oils, animal and vegetable fats, cereals and cereal products, frozen food, delicatessen products, food concentrates, meat and meat products, milk and milk products, non-alcoholic beverages (carbonated, still, juices, syrups), alcoholic beverages and spirit products, fruit and vegetables and fruit and vegetable products and vegetable-meat products, fish and fish products, sweets and confectionery products, food supplements, eggs and egg products, bread and bakery products, pastry products and semi-products","methodology_zh":"大肠菌群的检出","search_zh":"大肠菌群的检出 试管培养法 PN-ISO 4831:2007","technique_zh":"试管培养法"},{"_id":"6a8369ecaf14b9c0e7b1dc93","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Pasze, kawa i herbata, przyprawy, oleje, tłuszcze zwierzęce i roślinne, zboża i przetwory zbożowe, żywność mrożona, wyroby garmażeryjne, koncentraty spożywcze, mięso i produkty mięsne, mleko i produkty mleczne, napoje bezalkoholowe (gazowane, niegazowane, soki, syropy), napoje alkoholowe i wyroby spirytusowe, owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-mięsne, ryby i przetwory rybne, słodycze i wyroby cukiernicze, suplementy diety, jaja i produkty jajeczne, pieczywo i wyroby piekarnicze, wyroby i półprodukty ciastkarskie","methodology":"Liczba przypuszczalnych Bacillus cereus","parameters":[],"technique":"Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda płytkowa (posiew powierzchniowy)"],"computed":[],"activity":"Liczba przypuszczalnych Bacillus cereus\nMetoda płytkowa (posiew powierzchniowy)","reference":"PN-EN ISO 7932:2005+A1:2020-09 z wyłączeniem pkt. 9.5","norm_bases":["PN-EN ISO 7932:2005+A1:2020-09 z wyłączeniem pkt. 9.5"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pasze, kawa i herbata, przyprawy, oleje, tłuszcze zwierzęce i roślinne, zboża i przetwory zbożowe, żywność mrożona, wyroby garmażeryjne, koncentraty spożywcze, mięso i produkty mięsne, mleko i produkty mleczne, napoje bezalkoholowe (gazowane, niegazowane, soki, syropy), napoje alkoholowe i wyroby spirytusowe, owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-mięsne, ryby i przetwory rybne, słodycze i wyroby cukiernicze, suplementy diety, jaja i produkty jajeczne, pieczywo i wyroby piekarnicze, wyroby i półprodukty ciastkarskie Liczba przypuszczalnych Bacillus cereus\nMetoda płytkowa (posiew powierzchniowy) PN-EN ISO 7932:2005+A1:2020-09 z wyłączeniem pkt. 9.5 Pasze, kawa i herbata, przyprawy, oleje, tluszcze zwierzece i roslinne, zboza i przetwory zbozowe, zywnosc mrozona, wyroby garmazeryjne, koncentraty spozywcze, mieso i produkty miesne, mleko i produkty mleczne, napoje bezalkoholowe (gazowane, niegazowane, soki, syropy), napoje alkoholowe i wyroby spirytusowe, owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-miesne, ryby i przetwory rybne, slodycze i wyroby cukiernicze, suplementy diety, jaja i produkty jajeczne, pieczywo i wyroby piekarnicze, wyroby i polprodukty ciastkarskie Liczba przypuszczalnych Bacillus cereus\nMetoda plytkowa (posiew powierzchniowy) PN-EN ISO 7932:2005+A1:2020-09 z wylaczeniem pkt. 9.5","categories":["food","petro","pharma"],"row_index":113,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presumptive Bacillus cereus count","search_en":"Feed, coffee and tea, spices, oils, animal and vegetable fats, cereals and cereal products, frozen food, delicatessen products, food concentrates, meat and meat products, milk and milk products, non-alcoholic beverages (carbonated, still, juices, syrups), alcoholic beverages and spirit products, fruit and vegetables and fruit and vegetable products and vegetable-meat products, fish and fish products, sweets and confectionery products, food supplements, eggs and egg products, bread and bakery products, pastry products and semi-products Presumptive Bacillus cereus count Plate method (spread plate) PN-EN ISO 7932:2005+A1:2020-09 z wyłączeniem pkt. 9.5","technique_en":"Plate method (spread plate)","test_object_en":"Feed, coffee and tea, spices, oils, animal and vegetable fats, cereals and cereal products, frozen food, delicatessen products, food concentrates, meat and meat products, milk and milk products, non-alcoholic beverages (carbonated, still, juices, syrups), alcoholic beverages and spirit products, fruit and vegetables and fruit and vegetable products and vegetable-meat products, fish and fish products, sweets and confectionery products, food supplements, eggs and egg products, bread and bakery products, pastry products and semi-products","search_zh":"蜡样芽孢杆菌推定计数 平板法（表面涂布） PN-EN ISO 7932:2005+A1:2020-09 z wyłączeniem pkt. 9.5","technique_zh":"平板法（表面涂布）","methodology_zh":"蜡样芽孢杆菌推定计数"},{"_id":"6a8369ecaf14b9c0e7b1dc94","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Pasze, kawa i herbata, zboża i przetwory zbożowe, żywność mrożona, wyroby garmażeryjne, mięso i produkty mięsne, mleko i produkty mleczne, napoje bezalkoholowe (gazowane, niegazowane, soki, syropy), owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-mięsne, ryby i przetwory rybne, słodycze i wyroby cukiernicze","methodology":"Obecność beztlenowych bakterii przetrwalnikujących i/lub beztlenowych bakterii przetrwalnikujących redukujących siarczany (IV)","parameters":[],"technique":"Metoda hodowlana, probówkowa","techniques":["Metoda hodowlana, probówkowa"],"computed":[],"activity":"Obecność beztlenowych bakterii przetrwalnikujących i/lub beztlenowych bakterii przetrwalnikujących redukujących siarczany (IV)\nMetoda hodowlana, probówkowa","reference":"PB-PAZ/M-10 wersja 01 z dnia 01.03.2021 r.","norm_bases":["PB-PAZ/M-10 wersja 01 z dnia 01.03.2021 r."],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pasze, kawa i herbata, zboża i przetwory zbożowe, żywność mrożona, wyroby garmażeryjne, mięso i produkty mięsne, mleko i produkty mleczne, napoje bezalkoholowe (gazowane, niegazowane, soki, syropy), owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-mięsne, ryby i przetwory rybne, słodycze i wyroby cukiernicze Obecność beztlenowych bakterii przetrwalnikujących i/lub beztlenowych bakterii przetrwalnikujących redukujących siarczany (IV)\nMetoda hodowlana, probówkowa PB-PAZ/M-10 wersja 01 z dnia 01.03.2021 r. Pasze, kawa i herbata, zboza i przetwory zbozowe, zywnosc mrozona, wyroby garmazeryjne, mieso i produkty miesne, mleko i produkty mleczne, napoje bezalkoholowe (gazowane, niegazowane, soki, syropy), owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-miesne, ryby i przetwory rybne, slodycze i wyroby cukiernicze Obecnosc beztlenowych bakterii przetrwalnikujacych i/lub beztlenowych bakterii przetrwalnikujacych redukujacych siarczany (IV)\nMetoda hodowlana, probowkowa PB-PAZ/M-10 wersja 01 z dnia 01.03.2021 r.","categories":["food","microbiology"],"row_index":114,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of anaerobic spore-forming bacteria and/or sulphite (IV)-reducing anaerobic spore-forming bacteria","search_en":"Feed, coffee and tea, cereals and cereal products, frozen food, delicatessen products, meat and meat products, milk and dairy products, non-alcoholic beverages (carbonated, still, juices, syrups), fruit and vegetables and fruit, vegetable and vegetable-meat products, fish and fish products, sweets and confectionery Presence of anaerobic spore-forming bacteria and/or sulphite (IV)-reducing anaerobic spore-forming bacteria Culture method, tube PB-PAZ/M-10 wersja 01 z dnia 01.03.2021 r.","technique_en":"Culture method, tube","test_object_en":"Feed, coffee and tea, cereals and cereal products, frozen food, delicatessen products, meat and meat products, milk and dairy products, non-alcoholic beverages (carbonated, still, juices, syrups), fruit and vegetables and fruit, vegetable and vegetable-meat products, fish and fish products, sweets and confectionery","search_zh":"试管培养法 PB-PAZ/M-10 wersja 01 z dnia 01.03.2021 r.","technique_zh":"试管培养法"},{"_id":"6a8369ecaf14b9c0e7b1dc95","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Pasze oleje, tłuszcze zwierzęce i roślinne, żywność mrożona, wyroby garmażeryjne, mięso i produkty mięsne, mleko i produkty mleczne, owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-mięsne, ryby i przetwory rybne, słodycze i wyroby cukiernicze, jaja i produkty jajeczne","methodology":"Obecność Clostridium perfringens","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Obecność Clostridium perfringens\nMetoda płytkowa (posiew wgłębny)","reference":"PB-PAZ/M-07 wersja 01 z dnia 01.03.2021 r.","norm_bases":["PB-PAZ/M-07 wersja 01 z dnia 01.03.2021 r."],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pasze oleje, tłuszcze zwierzęce i roślinne, żywność mrożona, wyroby garmażeryjne, mięso i produkty mięsne, mleko i produkty mleczne, owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-mięsne, ryby i przetwory rybne, słodycze i wyroby cukiernicze, jaja i produkty jajeczne Obecność Clostridium perfringens\nMetoda płytkowa (posiew wgłębny) PB-PAZ/M-07 wersja 01 z dnia 01.03.2021 r. Pasze oleje, tluszcze zwierzece i roslinne, zywnosc mrozona, wyroby garmazeryjne, mieso i produkty miesne, mleko i produkty mleczne, owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-miesne, ryby i przetwory rybne, slodycze i wyroby cukiernicze, jaja i produkty jajeczne Obecnosc Clostridium perfringens\nMetoda plytkowa (posiew wglebny) PB-PAZ/M-07 wersja 01 z dnia 01.03.2021 r.","categories":["food","petro"],"row_index":115,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of Clostridium perfringens","search_en":"Feed oils, animal and vegetable fats, frozen food, delicatessen products, meat and meat products, milk and dairy products, fruit and vegetables and fruit, vegetable and vegetable-meat products, fish and fish products, sweets and confectionery, eggs and egg products Presence of Clostridium perfringens Plate method (pour plate) PB-PAZ/M-07 wersja 01 z dnia 01.03.2021 r.","technique_en":"Plate method (pour plate)","test_object_en":"Feed oils, animal and vegetable fats, frozen food, delicatessen products, meat and meat products, milk and dairy products, fruit and vegetables and fruit, vegetable and vegetable-meat products, fish and fish products, sweets and confectionery, eggs and egg products","search_zh":"产气荚膜梭菌的检出 平板法（倾注培养） PB-PAZ/M-07 wersja 01 z dnia 01.03.2021 r.","technique_zh":"平板法（倾注培养）","methodology_zh":"产气荚膜梭菌的检出"},{"_id":"6a8369ecaf14b9c0e7b1dc96","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Pasze, zboża i przetwory zbożowe, wyroby garmażeryjne, mięso i produkty mięsne, mleko i produkty mleczne, owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-mięsne","methodology":"Liczba bakterii tlenowych przetrwalnikujących mezofilnych","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba bakterii tlenowych przetrwalnikujących mezofilnych\nMetoda płytkowa (posiew wgłębny)","reference":"PB-PAZ/M-06 wersja 01 z dnia 01.03.2021 r.","norm_bases":["PB-PAZ/M-06 wersja 01 z dnia 01.03.2021 r."],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pasze, zboża i przetwory zbożowe, wyroby garmażeryjne, mięso i produkty mięsne, mleko i produkty mleczne, owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-mięsne Liczba bakterii tlenowych przetrwalnikujących mezofilnych\nMetoda płytkowa (posiew wgłębny) PB-PAZ/M-06 wersja 01 z dnia 01.03.2021 r. Pasze, zboza i przetwory zbozowe, wyroby garmazeryjne, mieso i produkty miesne, mleko i produkty mleczne, owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-miesne Liczba bakterii tlenowych przetrwalnikujacych mezofilnych\nMetoda plytkowa (posiew wglebny) PB-PAZ/M-06 wersja 01 z dnia 01.03.2021 r.","categories":["food","microbiology"],"row_index":116,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Count of mesophilic aerobic spore-forming bacteria","search_en":"Feed, cereals and cereal products, delicatessen products, meat and meat products, milk and dairy products, fruit and vegetables and fruit, vegetable and vegetable-meat products Count of mesophilic aerobic spore-forming bacteria Plate method (pour plate) PB-PAZ/M-06 wersja 01 z dnia 01.03.2021 r.","technique_en":"Plate method (pour plate)","test_object_en":"Feed, cereals and cereal products, delicatessen products, meat and meat products, milk and dairy products, fruit and vegetables and fruit, vegetable and vegetable-meat products","search_zh":"平板法（倾注培养） PB-PAZ/M-06 wersja 01 z dnia 01.03.2021 r.","technique_zh":"平板法（倾注培养）"},{"_id":"6a8369ecaf14b9c0e7b1dc97","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Pasze, wyroby garmażeryjne, mięso i produkty mięsne, mleko i produkty mleczne, napoje bezalkoholowe (gazowane, niegazowane, soki, syropy), owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-mięsne, ryby i przetwory rybne","methodology":"Szczelność opakowania","parameters":[],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Szczelność opakowania\nMetoda wizualna","reference":"PB-PAZ/M-05 wersja 01 z dnia 01.03.2021 r.","norm_bases":["PB-PAZ/M-05 wersja 01 z dnia 01.03.2021 r."],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pasze, wyroby garmażeryjne, mięso i produkty mięsne, mleko i produkty mleczne, napoje bezalkoholowe (gazowane, niegazowane, soki, syropy), owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-mięsne, ryby i przetwory rybne Szczelność opakowania\nMetoda wizualna PB-PAZ/M-05 wersja 01 z dnia 01.03.2021 r. Pasze, wyroby garmazeryjne, mieso i produkty miesne, mleko i produkty mleczne, napoje bezalkoholowe (gazowane, niegazowane, soki, syropy), owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-miesne, ryby i przetwory rybne Szczelnosc opakowania\nMetoda wizualna PB-PAZ/M-05 wersja 01 z dnia 01.03.2021 r.","categories":["food"],"row_index":117,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Package tightness","search_en":"Feed, delicatessen products, meat and meat products, milk and dairy products, non-alcoholic beverages (carbonated, still, juices, syrups), fruit and vegetables and fruit, vegetable and vegetable-meat products, fish and fish products Package tightness Visual method PB-PAZ/M-05 wersja 01 z dnia 01.03.2021 r.","technique_en":"Visual method","test_object_en":"Feed, delicatessen products, meat and meat products, milk and dairy products, non-alcoholic beverages (carbonated, still, juices, syrups), fruit and vegetables and fruit, vegetable and vegetable-meat products, fish and fish products","search_zh":"包装密封性 目视法 PB-PAZ/M-05 wersja 01 z dnia 01.03.2021 r.","technique_zh":"目视法","methodology_zh":"包装密封性"},{"_id":"6a8369ecaf14b9c0e7b1dc98","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Pasze, przyprawy, zboża i przetwory zbożowe, wyroby garmażeryjne, mięso i produkty mięsne, mleko i produkty mleczne, owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-mięsne, słodycze i wyroby cukiernicze, suplementy diety, jaja i produkty jajeczne","methodology":"Obecność Salmonella spp","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność Salmonella spp\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PB-PAZ/M-09 wersja 01 z dnia 01.03.2021 r.","norm_bases":["PB-PAZ/M-09 wersja 01 z dnia 01.03.2021 r."],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pasze, przyprawy, zboża i przetwory zbożowe, wyroby garmażeryjne, mięso i produkty mięsne, mleko i produkty mleczne, owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-mięsne, słodycze i wyroby cukiernicze, suplementy diety, jaja i produkty jajeczne Obecność Salmonella spp\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB-PAZ/M-09 wersja 01 z dnia 01.03.2021 r. Pasze, przyprawy, zboza i przetwory zbozowe, wyroby garmazeryjne, mieso i produkty miesne, mleko i produkty mleczne, owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-miesne, slodycze i wyroby cukiernicze, suplementy diety, jaja i produkty jajeczne Obecnosc Salmonella spp\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB-PAZ/M-09 wersja 01 z dnia 01.03.2021 r.","categories":["food","microbiology","pharma"],"row_index":118,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of Salmonella spp","search_en":"Feed, spices, cereals and cereal products, delicatessen products, meat and meat products, milk and dairy products, fruit and vegetables and fruit, vegetable and vegetable-meat products, sweets and confectionery, food supplements, eggs and egg products Presence of Salmonella spp Culture method with biochemical and serological confirmation PB-PAZ/M-09 wersja 01 z dnia 01.03.2021 r.","technique_en":"Culture method with biochemical and serological confirmation","test_object_en":"Feed, spices, cereals and cereal products, delicatessen products, meat and meat products, milk and dairy products, fruit and vegetables and fruit, vegetable and vegetable-meat products, sweets and confectionery, food supplements, eggs and egg products","search_zh":"沙门氏菌属（Salmonella spp）的检出 培养法结合生化与血清学确认 PB-PAZ/M-09 wersja 01 z dnia 01.03.2021 r.","technique_zh":"培养法结合生化与血清学确认","methodology_zh":"沙门氏菌属（Salmonella spp）的检出"},{"_id":"6a8369ecaf14b9c0e7b1dc99","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Mleko i produkty mleczne poddane obróbce termicznej, surowe mięso i produkty mięsne ready-to-cook RTC (z wyjątkiem mięsa drobiowego), produkty mięsne ready-to-eat RTE i ready-to-reheat RTRH (z wyjątkiem produktów z mięsa drobiowego), surowe mięso drobiowe i produkty drobiowe ready-to-cook RTC, produkty z mięsa drobiowego ready-to-eat RTE i ready-to-reheat RTRH, jaja i produkty jajeczne, surowe ryby i owoce morza, ryby i owoce morza ready-to-cook RTC (nieprzetworzone); produkty rybne i owoce morza ready-to-eat RTE i ready-to-reheat RTRH, świeże produkty roślinne (w tym owoce, warzywa, świeże przyprawy), przetworzone owoce i warzywa, suszone zboża, owoce, orzechy, nasiona zioła i warzywa; bakalie, grzyby, preparaty do początkowego żywienia niemowląt i płatki zbożowe dla niemowląt, czekolada, wyroby piekarnicze i cukiernicze, żywność złożona (wieloskładnikowa) lub składniki posiłków, dania gotowe, karma dla zwierząt domowych i pasze, kawa i herbata, oleje, tłuszcze zwierzęce i roślinne, napoje alkoholowe i wyroby spirytusowe, suplementy diety","methodology":"Liczba Clostridium spp. redukujących siarczany (IV)","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba Clostridium spp. redukujących siarczany (IV)\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 15213-1:2023-08 +Ap1:2024-02","norm_bases":["PN-EN ISO 15213-1:2023-08 +Ap1:2024-02"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mleko i produkty mleczne poddane obróbce termicznej, surowe mięso i produkty mięsne ready-to-cook RTC (z wyjątkiem mięsa drobiowego), produkty mięsne ready-to-eat RTE i ready-to-reheat RTRH (z wyjątkiem produktów z mięsa drobiowego), surowe mięso drobiowe i produkty drobiowe ready-to-cook RTC, produkty z mięsa drobiowego ready-to-eat RTE i ready-to-reheat RTRH, jaja i produkty jajeczne, surowe ryby i owoce morza, ryby i owoce morza ready-to-cook RTC (nieprzetworzone); produkty rybne i owoce morza ready-to-eat RTE i ready-to-reheat RTRH, świeże produkty roślinne (w tym owoce, warzywa, świeże przyprawy), przetworzone owoce i warzywa, suszone zboża, owoce, orzechy, nasiona zioła i warzywa; bakalie, grzyby, preparaty do początkowego żywienia niemowląt i płatki zbożowe dla niemowląt, czekolada, wyroby piekarnicze i cukiernicze, żywność złożona (wieloskładnikowa) lub składniki posiłków, dania gotowe, karma dla zwierząt domowych i pasze, kawa i herbata, oleje, tłuszcze zwierzęce i roślinne, napoje alkoholowe i wyroby spirytusowe, suplementy diety Liczba Clostridium spp. redukujących siarczany (IV)\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 15213-1:2023-08 +Ap1:2024-02 Mleko i produkty mleczne poddane obrobce termicznej, surowe mieso i produkty miesne ready-to-cook RTC (z wyjatkiem miesa drobiowego), produkty miesne ready-to-eat RTE i ready-to-reheat RTRH (z wyjatkiem produktow z miesa drobiowego), surowe mieso drobiowe i produkty drobiowe ready-to-cook RTC, produkty z miesa drobiowego ready-to-eat RTE i ready-to-reheat RTRH, jaja i produkty jajeczne, surowe ryby i owoce morza, ryby i owoce morza ready-to-cook RTC (nieprzetworzone); produkty rybne i owoce morza ready-to-eat RTE i ready-to-reheat RTRH, swieze produkty roslinne (w tym owoce, warzywa, swieze przyprawy), przetworzone owoce i warzywa, suszone zboza, owoce, orzechy, nasiona ziola i warzywa; bakalie, grzyby, preparaty do poczatkowego zywienia niemowlat i platki zbozowe dla niemowlat, czekolada, wyroby piekarnicze i cukiernicze, zywnosc zlozona (wieloskladnikowa) lub skladniki posilkow, dania gotowe, karma dla zwierzat domowych i pasze, kawa i herbata, oleje, tluszcze zwierzece i roslinne, napoje alkoholowe i wyroby spirytusowe, suplementy diety Liczba Clostridium spp. redukujacych siarczany (IV)\nMetoda plytkowa (posiew wglebny) PN-EN ISO 15213-1:2023-08 +Ap1:2024-02","categories":["food","petro","microbiology","pharma"],"row_index":119,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Count of sulphate (IV) reducing Clostridium spp.","search_en":"Count of sulphate (IV) reducing Clostridium spp. Plate method (pour plate) PN-EN ISO 15213-1:2023-08 +Ap1:2024-02","technique_en":"Plate method (pour plate)","search_zh":"硫酸盐(IV)还原梭菌属（Clostridium spp.）计数 平板法（倾注培养） PN-EN ISO 15213-1:2023-08 +Ap1:2024-02","technique_zh":"平板法（倾注培养）","methodology_zh":"硫酸盐(IV)还原梭菌属（Clostridium spp.）计数"},{"_id":"6a8369ecaf14b9c0e7b1dc9a","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Mleko i produkty mleczne poddane obróbce termicznej, surowe mięso i produkty mięsne ready-to-cook RTC (z wyjątkiem mięsa drobiowego), produkty mięsne ready-to-eat RTE i ready-to-reheat RTRH (z wyjątkiem produktów z mięsa drobiowego), surowe mięso drobiowe i produkty drobiowe ready-to-cook RTC, produkty z mięsa drobiowego ready-to-eat RTE i ready-to-reheat RTRH, jaja i produkty jajeczne; surowe ryby i owoce morza, ryby i owoce morza ready-to-cook RTC (nieprzetworzone), produkty rybne i owoce morza ready-to-eat RTE i ready-to-reheat RTRH, świeże produkty roślinne (w tym owoce, warzywa, świeże przyprawy), przetworzone owoce i warzywa, suszone zboża, owoce, orzechy, nasiona i warzywa, preparaty do początkowego żywienia niemowląt i płatki zbożowe dla niemowląt, czekolada, wyroby piekarnicze i cukiernicze, żywność złożona (wieloskładnikowa) lub składniki posiłków, dania gotowe, karma dla zwierząt domowych i pasze, kawa i herbata, oleje, tłuszcze zwierzęce i roślinne, napoje alkoholowe i wyroby spirytusowe, suplementy diety","methodology":"Liczba Clostridium perfringens","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba Clostridium perfringens\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 15213-2:2024-05","norm_bases":["PN-EN ISO 15213-2:2024-05"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mleko i produkty mleczne poddane obróbce termicznej, surowe mięso i produkty mięsne ready-to-cook RTC (z wyjątkiem mięsa drobiowego), produkty mięsne ready-to-eat RTE i ready-to-reheat RTRH (z wyjątkiem produktów z mięsa drobiowego), surowe mięso drobiowe i produkty drobiowe ready-to-cook RTC, produkty z mięsa drobiowego ready-to-eat RTE i ready-to-reheat RTRH, jaja i produkty jajeczne; surowe ryby i owoce morza, ryby i owoce morza ready-to-cook RTC (nieprzetworzone), produkty rybne i owoce morza ready-to-eat RTE i ready-to-reheat RTRH, świeże produkty roślinne (w tym owoce, warzywa, świeże przyprawy), przetworzone owoce i warzywa, suszone zboża, owoce, orzechy, nasiona i warzywa, preparaty do początkowego żywienia niemowląt i płatki zbożowe dla niemowląt, czekolada, wyroby piekarnicze i cukiernicze, żywność złożona (wieloskładnikowa) lub składniki posiłków, dania gotowe, karma dla zwierząt domowych i pasze, kawa i herbata, oleje, tłuszcze zwierzęce i roślinne, napoje alkoholowe i wyroby spirytusowe, suplementy diety Liczba Clostridium perfringens\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 15213-2:2024-05 Mleko i produkty mleczne poddane obrobce termicznej, surowe mieso i produkty miesne ready-to-cook RTC (z wyjatkiem miesa drobiowego), produkty miesne ready-to-eat RTE i ready-to-reheat RTRH (z wyjatkiem produktow z miesa drobiowego), surowe mieso drobiowe i produkty drobiowe ready-to-cook RTC, produkty z miesa drobiowego ready-to-eat RTE i ready-to-reheat RTRH, jaja i produkty jajeczne; surowe ryby i owoce morza, ryby i owoce morza ready-to-cook RTC (nieprzetworzone), produkty rybne i owoce morza ready-to-eat RTE i ready-to-reheat RTRH, swieze produkty roslinne (w tym owoce, warzywa, swieze przyprawy), przetworzone owoce i warzywa, suszone zboza, owoce, orzechy, nasiona i warzywa, preparaty do poczatkowego zywienia niemowlat i platki zbozowe dla niemowlat, czekolada, wyroby piekarnicze i cukiernicze, zywnosc zlozona (wieloskladnikowa) lub skladniki posilkow, dania gotowe, karma dla zwierzat domowych i pasze, kawa i herbata, oleje, tluszcze zwierzece i roslinne, napoje alkoholowe i wyroby spirytusowe, suplementy diety Liczba Clostridium perfringens\nMetoda plytkowa (posiew wglebny) PN-EN ISO 15213-2:2024-05","categories":["food","petro","pharma"],"row_index":120,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Clostridium perfringens count","search_en":"Clostridium perfringens count Plate method (pour plate) PN-EN ISO 15213-2:2024-05","technique_en":"Plate method (pour plate)","search_zh":"产气荚膜梭菌计数 平板法（倾注培养） PN-EN ISO 15213-2:2024-05","technique_zh":"平板法（倾注培养）","methodology_zh":"产气荚膜梭菌计数"},{"_id":"6a8369ecaf14b9c0e7b1dc9b","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Pasze, kawa i herbata, przyprawy, oleje, tłuszcze zwierzęce i roślinne, zboża i przetwory zbożowe, żywność mrożona, wyroby garmażeryjne, koncentraty spożywcze, mięso i produkty mięsne, mleko i produkty mleczne, napoje bezalkoholowe (gazowane, niegazowane, soki, syropy), napoje alkoholowe i wyroby spirytusowe, owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-mięsne, ryby i przetwory rybne, słodycze i wyroby cukiernicze, suplementy diety, jaja i produkty jajeczne","methodology":"Liczba bakterii fermentacji mlekowej","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba bakterii fermentacji mlekowej\nMetoda płytkowa (posiew wgłębny)","reference":"PN-ISO 15214:2002","norm_bases":["PN-ISO 15214:2002"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pasze, kawa i herbata, przyprawy, oleje, tłuszcze zwierzęce i roślinne, zboża i przetwory zbożowe, żywność mrożona, wyroby garmażeryjne, koncentraty spożywcze, mięso i produkty mięsne, mleko i produkty mleczne, napoje bezalkoholowe (gazowane, niegazowane, soki, syropy), napoje alkoholowe i wyroby spirytusowe, owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-mięsne, ryby i przetwory rybne, słodycze i wyroby cukiernicze, suplementy diety, jaja i produkty jajeczne Liczba bakterii fermentacji mlekowej\nMetoda płytkowa (posiew wgłębny) PN-ISO 15214:2002 Pasze, kawa i herbata, przyprawy, oleje, tluszcze zwierzece i roslinne, zboza i przetwory zbozowe, zywnosc mrozona, wyroby garmazeryjne, koncentraty spozywcze, mieso i produkty miesne, mleko i produkty mleczne, napoje bezalkoholowe (gazowane, niegazowane, soki, syropy), napoje alkoholowe i wyroby spirytusowe, owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-miesne, ryby i przetwory rybne, slodycze i wyroby cukiernicze, suplementy diety, jaja i produkty jajeczne Liczba bakterii fermentacji mlekowej\nMetoda plytkowa (posiew wglebny) PN-ISO 15214:2002","categories":["food","petro","microbiology","pharma"],"row_index":121,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Lactic acid bacteria count","search_en":"Feed, coffee and tea, spices, oils, animal and vegetable fats, cereals and cereal products, frozen food, delicatessen products, food concentrates, meat and meat products, milk and milk products, non-alcoholic beverages (carbonated, still, juices, syrups), alcoholic beverages and spirit products, fruit and vegetables and fruit and vegetable products and vegetable-meat products, fish and fish products, sweets and confectionery products, food supplements, eggs and egg products Lactic acid bacteria count Plate method (pour plate) PN-ISO 15214:2002","technique_en":"Plate method (pour plate)","test_object_en":"Feed, coffee and tea, spices, oils, animal and vegetable fats, cereals and cereal products, frozen food, delicatessen products, food concentrates, meat and meat products, milk and milk products, non-alcoholic beverages (carbonated, still, juices, syrups), alcoholic beverages and spirit products, fruit and vegetables and fruit and vegetable products and vegetable-meat products, fish and fish products, sweets and confectionery products, food supplements, eggs and egg products","search_zh":"乳酸发酵菌数 平板法（倾注培养） PN-ISO 15214:2002","technique_zh":"平板法（倾注培养）","methodology_zh":"乳酸发酵菌数"},{"_id":"6a8369ecaf14b9c0e7b1dc9c","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Mięso i produkty mięsne","methodology":"Liczba Pseudomonas spp.","parameters":[],"technique":"Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda płytkowa (posiew powierzchniowy)"],"computed":[],"activity":"Liczba Pseudomonas spp.\nMetoda płytkowa (posiew powierzchniowy)","reference":"PN-ISO 13720:2010","norm_bases":["PN-ISO 13720:2010"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i produkty mięsne Liczba Pseudomonas spp.\nMetoda płytkowa (posiew powierzchniowy) PN-ISO 13720:2010 Mieso i produkty miesne Liczba Pseudomonas spp.\nMetoda plytkowa (posiew powierzchniowy) PN-ISO 13720:2010","categories":["food"],"row_index":122,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Count of Pseudomonas spp.","search_en":"Meat and meat products Count of Pseudomonas spp. Plate method (spread plate) PN-ISO 13720:2010","technique_en":"Plate method (spread plate)","test_object_en":"Meat and meat products","search_zh":"肉与肉制品 平板法（表面涂布） PN-ISO 13720:2010","technique_zh":"平板法（表面涂布）","test_object_zh":"肉与肉制品"},{"_id":"6a8369ecaf14b9c0e7b1dc9d","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Świeże mięso drobiowe, Tusze drobiowe","methodology":"Obecność i identyfikacja Salmonella, Typhimurium i Salmonella, Enteritidis","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność i identyfikacja Salmonella, Typhimurium i Salmonella, Enteritidis\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PN-EN ISO 6579-1:2017-04 +A1:2020-09 ISO/TR 6579-3:2014","norm_bases":["PN-EN ISO 6579-1:2017-04 +A1:2020-09 ISO/TR 6579-3:2014"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Świeże mięso drobiowe, Tusze drobiowe Obecność i identyfikacja Salmonella, Typhimurium i Salmonella, Enteritidis\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579-1:2017-04 +A1:2020-09 ISO/TR 6579-3:2014 Swieze mieso drobiowe, Tusze drobiowe Obecnosc i identyfikacja Salmonella, Typhimurium i Salmonella, Enteritidis\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579-1:2017-04 +A1:2020-09 ISO/TR 6579-3:2014","categories":["microbiology","food"],"row_index":123,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Fresh poultry meat, Poultry carcasses Culture method with biochemical and serological confirmation PN-EN ISO 6579-1:2017-04 +A1:2020-09 ISO/TR 6579-3:2014","technique_en":"Culture method with biochemical and serological confirmation","test_object_en":"Fresh poultry meat, Poultry carcasses","search_zh":"培养法结合生化与血清学确认 PN-EN ISO 6579-1:2017-04 +A1:2020-09 ISO/TR 6579-3:2014","technique_zh":"培养法结合生化与血清学确认"},{"_id":"6a8369ecaf14b9c0e7b1dc9e","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Napoje bezalkoholowe (gazowane, niegazowane, soki, syropy)","methodology":"Liczba bakterii w 22 oC","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba bakterii w 22 oC\nMetoda płytkowa (posiew wgłębny)","reference":"PN-85/A-79033","norm_bases":["PN-85/A-79033"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Napoje bezalkoholowe (gazowane, niegazowane, soki, syropy) Liczba bakterii w 22 oC\nMetoda płytkowa (posiew wgłębny) PN-85/A-79033 Napoje bezalkoholowe (gazowane, niegazowane, soki, syropy) Liczba bakterii w 22 oC\nMetoda plytkowa (posiew wglebny) PN-85/A-79033","categories":["food","microbiology"],"row_index":124,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Bacteria count at 22 oC","search_en":"Non-alcoholic beverages (carbonated, still, juices, syrups) Bacteria count at 22 oC Plate method (pour plate) PN-85/A-79033","technique_en":"Plate method (pour plate)","test_object_en":"Non-alcoholic beverages (carbonated, still, juices, syrups)","search_zh":"平板法（倾注培养） PN-85/A-79033","technique_zh":"平板法（倾注培养）"},{"_id":"6a8369ecaf14b9c0e7b1dc9f","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Napoje bezalkoholowe (gazowane, niegazowane, soki, syropy)","methodology":"Liczba bakterii w 37 oC","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba bakterii w 37 oC\nMetoda płytkowa (posiew wgłębny)","reference":"PN-85/A-79033","norm_bases":["PN-85/A-79033"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Napoje bezalkoholowe (gazowane, niegazowane, soki, syropy) Liczba bakterii w 37 oC\nMetoda płytkowa (posiew wgłębny) PN-85/A-79033 Napoje bezalkoholowe (gazowane, niegazowane, soki, syropy) Liczba bakterii w 37 oC\nMetoda plytkowa (posiew wglebny) PN-85/A-79033","categories":["food","microbiology"],"row_index":125,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Bacteria count at 37 oC","search_en":"Non-alcoholic beverages (carbonated, still, juices, syrups) Bacteria count at 37 oC Plate method (pour plate) PN-85/A-79033","technique_en":"Plate method (pour plate)","test_object_en":"Non-alcoholic beverages (carbonated, still, juices, syrups)","search_zh":"平板法（倾注培养） PN-85/A-79033","technique_zh":"平板法（倾注培养）"},{"_id":"6a8369ecaf14b9c0e7b1dca0","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-mięsne, napoje bezalkoholowe (gazowane, niegazowane, syropy, soki), zboża i przetwory zbożowe, wyroby garmażeryjne, żywność mrożona","methodology":"Liczba pleśni termoopornych","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba pleśni termoopornych\nMetoda płytkowa (posiew wgłębny)","reference":"PB-PAZ/M-12 wersja 01 z dnia 01.03.2021 r. na podstawie IFU Method No 4, April 1996","norm_bases":["PB-PAZ/M-12 wersja 01 z dnia 01.03.2021 r. na podstawie IFU Method No 4, April 1996"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-mięsne, napoje bezalkoholowe (gazowane, niegazowane, syropy, soki), zboża i przetwory zbożowe, wyroby garmażeryjne, żywność mrożona Liczba pleśni termoopornych\nMetoda płytkowa (posiew wgłębny) PB-PAZ/M-12 wersja 01 z dnia 01.03.2021 r. na podstawie IFU Method No 4, April 1996 Owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-miesne, napoje bezalkoholowe (gazowane, niegazowane, syropy, soki), zboza i przetwory zbozowe, wyroby garmazeryjne, zywnosc mrozona Liczba plesni termoopornych\nMetoda plytkowa (posiew wglebny) PB-PAZ/M-12 wersja 01 z dnia 01.03.2021 r. na podstawie IFU Method No 4, April 1996","categories":["food"],"row_index":126,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Count of heat-resistant moulds","search_en":"Fruit and vegetables and fruit, vegetable and vegetable-meat products, non-alcoholic beverages (carbonated, still, syrups, juices), cereals and cereal products, delicatessen products, frozen food Count of heat-resistant moulds Plate method (pour plate) PB-PAZ/M-12 wersja 01 z dnia 01.03.2021 r. na podstawie IFU Method No 4, April 1996","technique_en":"Plate method (pour plate)","test_object_en":"Fruit and vegetables and fruit, vegetable and vegetable-meat products, non-alcoholic beverages (carbonated, still, syrups, juices), cereals and cereal products, delicatessen products, frozen food","search_zh":"平板法（倾注培养） PB-PAZ/M-12 wersja 01 z dnia 01.03.2021 r. na podstawie IFU Method No 4, April 1996","technique_zh":"平板法（倾注培养）"},{"_id":"6a8369ecaf14b9c0e7b1dca1","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Wyroby garmażeryjne, Drób i przetwory drobiarskie, mleko i produkty mleczne, przetwory warzywno-mięsne, jaja i produkty jajeczne","methodology":"Liczba Campylobacter spp.","parameters":[],"technique":"Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda płytkowa (posiew powierzchniowy)"],"computed":[],"activity":"Liczba Campylobacter spp.\nMetoda płytkowa (posiew powierzchniowy)","reference":"PN-EN ISO 10272-2:2017-10 +A1:2023-08","norm_bases":["PN-EN ISO 10272-2:2017-10 +A1:2023-08"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby garmażeryjne, Drób i przetwory drobiarskie, mleko i produkty mleczne, przetwory warzywno-mięsne, jaja i produkty jajeczne Liczba Campylobacter spp.\nMetoda płytkowa (posiew powierzchniowy) PN-EN ISO 10272-2:2017-10 +A1:2023-08 Wyroby garmazeryjne, Drob i przetwory drobiarskie, mleko i produkty mleczne, przetwory warzywno-miesne, jaja i produkty jajeczne Liczba Campylobacter spp.\nMetoda plytkowa (posiew powierzchniowy) PN-EN ISO 10272-2:2017-10 +A1:2023-08","categories":["food"],"row_index":127,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Campylobacter spp. count","search_en":"Delicatessen products, Poultry and poultry products, milk and milk products, vegetable-meat preserves, eggs and egg products Campylobacter spp. count Plate method (spread plate) PN-EN ISO 10272-2:2017-10 +A1:2023-08","technique_en":"Plate method (spread plate)","test_object_en":"Delicatessen products, Poultry and poultry products, milk and milk products, vegetable-meat preserves, eggs and egg products","search_zh":"弯曲杆菌属计数 平板法（表面涂布） PN-EN ISO 10272-2:2017-10 +A1:2023-08","technique_zh":"平板法（表面涂布）","methodology_zh":"弯曲杆菌属计数"},{"_id":"6a8369ecaf14b9c0e7b1dca2","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Pasze, kawa i herbata, przyprawy, oleje, tłuszcze zwierzęce i roślinne, zboża i przetwory zbożowe, żywność mrożona, wyroby garmażeryjne, koncentraty spożywcze, mięso i produkty mięsne, produkty mleczne, napoje bezalkoholowe (gazowane, niegazowane, soki, syropy), napoje alkoholowe owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-mięsne, ryby i przetwory rybne, słodycze i wyroby cukiernicze, suplementy diety, pieczywo i wyroby piekarnicze oraz wyroby i półprodukty ciastkarskie","methodology":"Liczba drożdży i pleśni","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba drożdży i pleśni\nMetoda płytkowa (posiew wgłębny)","reference":"PN-ISO 7954:1999","norm_bases":["PN-ISO 7954:1999"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pasze, kawa i herbata, przyprawy, oleje, tłuszcze zwierzęce i roślinne, zboża i przetwory zbożowe, żywność mrożona, wyroby garmażeryjne, koncentraty spożywcze, mięso i produkty mięsne, produkty mleczne, napoje bezalkoholowe (gazowane, niegazowane, soki, syropy), napoje alkoholowe owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-mięsne, ryby i przetwory rybne, słodycze i wyroby cukiernicze, suplementy diety, pieczywo i wyroby piekarnicze oraz wyroby i półprodukty ciastkarskie Liczba drożdży i pleśni\nMetoda płytkowa (posiew wgłębny) PN-ISO 7954:1999 Pasze, kawa i herbata, przyprawy, oleje, tluszcze zwierzece i roslinne, zboza i przetwory zbozowe, zywnosc mrozona, wyroby garmazeryjne, koncentraty spozywcze, mieso i produkty miesne, produkty mleczne, napoje bezalkoholowe (gazowane, niegazowane, soki, syropy), napoje alkoholowe owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-miesne, ryby i przetwory rybne, slodycze i wyroby cukiernicze, suplementy diety, pieczywo i wyroby piekarnicze oraz wyroby i polprodukty ciastkarskie Liczba drozdzy i plesni\nMetoda plytkowa (posiew wglebny) PN-ISO 7954:1999","categories":["food","petro","pharma"],"row_index":128,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Yeast and mould count","search_en":"Feed, coffee and tea, spices, oils, animal and vegetable fats, cereals and cereal products, frozen food, delicatessen products, food concentrates, meat and meat products, dairy products, non-alcoholic beverages (carbonated, still, juices, syrups), alcoholic beverages fruit and vegetables and fruit, vegetable and vegetable-meat products, fish and fish products, sweets and confectionery, food supplements, bread and bakery products and pastry products and semi-finished pastry products Yeast and mould count Plate method (pour plate) PN-ISO 7954:1999","technique_en":"Plate method (pour plate)","test_object_en":"Feed, coffee and tea, spices, oils, animal and vegetable fats, cereals and cereal products, frozen food, delicatessen products, food concentrates, meat and meat products, dairy products, non-alcoholic beverages (carbonated, still, juices, syrups), alcoholic beverages fruit and vegetables and fruit, vegetable and vegetable-meat products, fish and fish products, sweets and confectionery, food supplements, bread and bakery products and pastry products and semi-finished pastry products","methodology_zh":"酵母菌与霉菌计数","search_zh":"酵母菌与霉菌计数 平板法（倾注培养） PN-ISO 7954:1999","technique_zh":"平板法（倾注培养）"},{"_id":"6a8369ecaf14b9c0e7b1dca3","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Mięso i produkty mięsne, Pasze","methodology":"Obecność DNA dla gatunków mięsa:","parameters":[{"name":"wieprzowina"},{"name":"wołowina"},{"name":"konina"},{"name":"pochodzące od przeżuwaczy"}],"technique":"Metoda real – time PCR","techniques":["Metoda real – time PCR"],"computed":[],"activity":"Obecność DNA dla gatunków mięsa:\nZakres:\nwieprzowina\nwołowina\nkonina\npochodzące od przeżuwaczy\nMetoda real – time PCR","reference":"PB-PAZ/M-15 wersja 01 z dnia 01.03.2021 r. na podstawie instrukcji producenta GEN-IAL","norm_bases":["PB-PAZ/M-15 wersja 01 z dnia 01.03.2021 r. na podstawie instrukcji producenta GEN-IAL"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i produkty mięsne, Pasze Obecność DNA dla gatunków mięsa:\nZakres:\nwieprzowina\nwołowina\nkonina\npochodzące od przeżuwaczy\nMetoda real – time PCR PB-PAZ/M-15 wersja 01 z dnia 01.03.2021 r. na podstawie instrukcji producenta GEN-IAL Mieso i produkty miesne, Pasze Obecnosc DNA dla gatunkow miesa:\nZakres:\nwieprzowina\nwolowina\nkonina\npochodzace od przezuwaczy\nMetoda real – time PCR PB-PAZ/M-15 wersja 01 z dnia 01.03.2021 r. na podstawie instrukcji producenta GEN-IAL","categories":["food"],"row_index":129,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of DNA for meat species:","parameters_en":[{"name":"pork"},{"name":"beef"},{"name":"horse meat"},{"name":"originating from ruminants"}],"search_en":"Meat and meat products, Feed Presence of DNA for meat species: Real – time PCR method pork beef horse meat originating from ruminants PB-PAZ/M-15 wersja 01 z dnia 01.03.2021 r. na podstawie instrukcji producenta GEN-IAL","technique_en":"Real – time PCR method","test_object_en":"Meat and meat products, Feed","search_zh":"实时荧光定量 PCR 法 PB-PAZ/M-15 wersja 01 z dnia 01.03.2021 r. na podstawie instrukcji producenta GEN-IAL","technique_zh":"实时荧光定量 PCR 法"},{"_id":"6a8369ecaf14b9c0e7b1dca4","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Kawa i herbata, przyprawy, oleje, tłuszcze zwierzęce i roślinne, zboża i przetwory zbożowe, żywność mrożona, wyroby garmażeryjne, koncentraty spożywcze, mięso i produkty mięsne, mleko i produkty mleczne, napoje bezalkoholowe (gazowane, niegazowane, soki, syropy), owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-mięsne, ryby i przetwory rybne, słodycze i wyroby cukiernicze, suplementy diety, jaja i produkty jajeczne, grzyby","methodology":"Obecność DNA Listeria monocytogenes","parameters":[],"technique":"Metoda real – time PCR","techniques":["Metoda real – time PCR"],"computed":[],"activity":"Obecność DNA Listeria monocytogenes\nMetoda real – time PCR","reference":"PB-PAZ/M-13 wersja 01 z dnia 01.03.2021 r. na podstawie instrukcji producenta Bio-Rad","norm_bases":["PB-PAZ/M-13 wersja 01 z dnia 01.03.2021 r. na podstawie instrukcji producenta Bio-Rad"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kawa i herbata, przyprawy, oleje, tłuszcze zwierzęce i roślinne, zboża i przetwory zbożowe, żywność mrożona, wyroby garmażeryjne, koncentraty spożywcze, mięso i produkty mięsne, mleko i produkty mleczne, napoje bezalkoholowe (gazowane, niegazowane, soki, syropy), owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-mięsne, ryby i przetwory rybne, słodycze i wyroby cukiernicze, suplementy diety, jaja i produkty jajeczne, grzyby Obecność DNA Listeria monocytogenes\nMetoda real – time PCR PB-PAZ/M-13 wersja 01 z dnia 01.03.2021 r. na podstawie instrukcji producenta Bio-Rad Kawa i herbata, przyprawy, oleje, tluszcze zwierzece i roslinne, zboza i przetwory zbozowe, zywnosc mrozona, wyroby garmazeryjne, koncentraty spozywcze, mieso i produkty miesne, mleko i produkty mleczne, napoje bezalkoholowe (gazowane, niegazowane, soki, syropy), owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-miesne, ryby i przetwory rybne, slodycze i wyroby cukiernicze, suplementy diety, jaja i produkty jajeczne, grzyby Obecnosc DNA Listeria monocytogenes\nMetoda real – time PCR PB-PAZ/M-13 wersja 01 z dnia 01.03.2021 r. na podstawie instrukcji producenta Bio-Rad","categories":["food","microbiology","petro","pharma"],"row_index":130,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of Listeria monocytogenes DNA","search_en":"Coffee and tea, spices, oils, animal and vegetable fats, cereals and cereal products, frozen food, delicatessen products, food concentrates, meat and meat products, milk and dairy products, non-alcoholic beverages (carbonated, still, juices, syrups), fruit and vegetables and fruit and vegetable products and vegetable-meat products, fish and fish products, sweets and confectionery, dietary supplements, eggs and egg products, mushrooms Presence of Listeria monocytogenes DNA Real – time PCR method PB-PAZ/M-13 wersja 01 z dnia 01.03.2021 r. na podstawie instrukcji producenta Bio-Rad","technique_en":"Real – time PCR method","test_object_en":"Coffee and tea, spices, oils, animal and vegetable fats, cereals and cereal products, frozen food, delicatessen products, food concentrates, meat and meat products, milk and dairy products, non-alcoholic beverages (carbonated, still, juices, syrups), fruit and vegetables and fruit and vegetable products and vegetable-meat products, fish and fish products, sweets and confectionery, dietary supplements, eggs and egg products, mushrooms","methodology_zh":"单核细胞增生李斯特氏菌 DNA 的检出","search_zh":"单核细胞增生李斯特氏菌 DNA 的检出 实时荧光定量 PCR 法 PB-PAZ/M-13 wersja 01 z dnia 01.03.2021 r. na podstawie instrukcji producenta Bio-Rad","technique_zh":"实时荧光定量 PCR 法"},{"_id":"6a8369ecaf14b9c0e7b1dca5","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Pasze, Kawa rozpuszczalna i herbata, przyprawy, oleje, tłuszcze roślinne i zwierzęce, nasiona roślin oleistych, nasiona roślin strączkowych, zboża i przetwory zbożowe, wyroby garmażeryjne, koncentraty spożywcze, mięso i przetwory mięsne, mleko i przetwory mleczne, owoce i warzywa, przetwory owocowo - warzywne, konserwy, ryby, owoce morza i ich przetwory, wyroby i półprodukty ciastkarskie, pieczywo i wyroby piekarnicze, produkty ziemniaczane i zbożowe, jaja i ich produkty, suplementy diety, dodatki do żywności, majonez, słodycze i wyroby cukiernicze, cukier, bakalie i orzechy, grzyby, przetwory i półprzetwory grzybowe, napoje bezalkoholowe, wino i wyroby winiarskie, piwo, sosy i dresingi, żywność dla niemowląt, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością: - wymaz - popłuczyny","methodology":"Obecność DNA Salmonella spp","parameters":[],"technique":"Metoda real - time PCR","techniques":["Metoda real - time PCR"],"computed":[],"activity":"Obecność DNA Salmonella spp\nMetoda real - time PCR","reference":"PB-PAZ/M-02 wersja 02 z dnia 01.10.2022 r. na podstawie instrukcji producenta Biotecon","norm_bases":["PB-PAZ/M-02 wersja 02 z dnia 01.10.2022 r. na podstawie instrukcji producenta Biotecon"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pasze, Kawa rozpuszczalna i herbata, przyprawy, oleje, tłuszcze roślinne i zwierzęce, nasiona roślin oleistych, nasiona roślin strączkowych, zboża i przetwory zbożowe, wyroby garmażeryjne, koncentraty spożywcze, mięso i przetwory mięsne, mleko i przetwory mleczne, owoce i warzywa, przetwory owocowo - warzywne, konserwy, ryby, owoce morza i ich przetwory, wyroby i półprodukty ciastkarskie, pieczywo i wyroby piekarnicze, produkty ziemniaczane i zbożowe, jaja i ich produkty, suplementy diety, dodatki do żywności, majonez, słodycze i wyroby cukiernicze, cukier, bakalie i orzechy, grzyby, przetwory i półprzetwory grzybowe, napoje bezalkoholowe, wino i wyroby winiarskie, piwo, sosy i dresingi, żywność dla niemowląt, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością: - wymaz - popłuczyny Obecność DNA Salmonella spp\nMetoda real - time PCR PB-PAZ/M-02 wersja 02 z dnia 01.10.2022 r. na podstawie instrukcji producenta Biotecon Pasze, Kawa rozpuszczalna i herbata, przyprawy, oleje, tluszcze roslinne i zwierzece, nasiona roslin oleistych, nasiona roslin straczkowych, zboza i przetwory zbozowe, wyroby garmazeryjne, koncentraty spozywcze, mieso i przetwory miesne, mleko i przetwory mleczne, owoce i warzywa, przetwory owocowo - warzywne, konserwy, ryby, owoce morza i ich przetwory, wyroby i polprodukty ciastkarskie, pieczywo i wyroby piekarnicze, produkty ziemniaczane i zbozowe, jaja i ich produkty, suplementy diety, dodatki do zywnosci, majonez, slodycze i wyroby cukiernicze, cukier, bakalie i orzechy, grzyby, przetwory i polprzetwory grzybowe, napoje bezalkoholowe, wino i wyroby winiarskie, piwo, sosy i dresingi, zywnosc dla niemowlat, Probki srodowiskowe z obszarow produkcji zywnosci i obrotu zywnoscia: - wymaz - popluczyny Obecnosc DNA Salmonella spp\nMetoda real - time PCR PB-PAZ/M-02 wersja 02 z dnia 01.10.2022 r. na podstawie instrukcji producenta Biotecon","categories":["food","microbiology","environment","petro","pharma"],"row_index":131,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of Salmonella spp DNA","search_en":"Feed, Instant coffee and tea, spices, oils, vegetable and animal fats, oilseeds, legume seeds, cereals and cereal products, delicatessen products, food concentrates, meat and meat products, milk and dairy products, fruit and vegetables, fruit-vegetable products, canned products, fish, seafood and their products, pastry products and semi-finished pastry products, bread and bakery products, potato and cereal products, eggs and egg products, food supplements, food additives, mayonnaise, sweets and confectionery, sugar, dried fruit and nuts, mushrooms, mushroom products and semi-products, non-alcoholic beverages, wine and wine products, beer, sauces and dressings, infant food, Environmental samples from food production and food trade areas: - swab - rinse waters Presence of Salmonella spp DNA Real - time PCR method PB-PAZ/M-02 wersja 02 z dnia 01.10.2022 r. na podstawie instrukcji producenta Biotecon","technique_en":"Real - time PCR method","test_object_en":"Feed, Instant coffee and tea, spices, oils, vegetable and animal fats, oilseeds, legume seeds, cereals and cereal products, delicatessen products, food concentrates, meat and meat products, milk and dairy products, fruit and vegetables, fruit-vegetable products, canned products, fish, seafood and their products, pastry products and semi-finished pastry products, bread and bakery products, potato and cereal products, eggs and egg products, food supplements, food additives, mayonnaise, sweets and confectionery, sugar, dried fruit and nuts, mushrooms, mushroom products and semi-products, non-alcoholic beverages, wine and wine products, beer, sauces and dressings, infant food, Environmental samples from food production and food trade areas: - swab - rinse waters","search_zh":"实时荧光定量 PCR 法 PB-PAZ/M-02 wersja 02 z dnia 01.10.2022 r. na podstawie instrukcji producenta Biotecon","technique_zh":"实时荧光定量 PCR 法"},{"_id":"6a8369ecaf14b9c0e7b1dca6","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Koncentraty spożywcze, przyprawy, kawa rozpuszczalna, zboża i przetwory zbożowe, pieczywo i wyroby piekarnicze, wyroby i półprodukty ciastkarskie, produkty ziemniaczane i zbożowe, słodycze i wyroby cukiernicze, mięso i przetwory mięsne, wyroby garmażeryjne, konserwy, napoje alkoholowe, piwo, napoje bezalkoholowe, mleko i przetwory mleczne, przetwory owocowo-warzywne, sosy i dresingi, majonez, musztarda, suplementy diety, Próbki środowiskowe z obszarów produkcji żywności: – popłuczyny","methodology":"Obecność alergennych białek glutenu (gliadyn)","parameters":[],"technique":"Metoda immunoenzymatyczna (ELISA)","techniques":["Metoda immunoenzymatyczna (ELISA)"],"computed":[],"activity":"Obecność alergennych białek glutenu (gliadyn)\nMetoda immunoenzymatyczna (ELISA)","reference":"PB-PAZ/M-16 wersja 01 z dnia 01.03.2021 na podstawie instrukcji producenta Riopharm","norm_bases":["PB-PAZ/M-16 wersja 01 z dnia 01.03.2021 na podstawie instrukcji producenta Riopharm"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Koncentraty spożywcze, przyprawy, kawa rozpuszczalna, zboża i przetwory zbożowe, pieczywo i wyroby piekarnicze, wyroby i półprodukty ciastkarskie, produkty ziemniaczane i zbożowe, słodycze i wyroby cukiernicze, mięso i przetwory mięsne, wyroby garmażeryjne, konserwy, napoje alkoholowe, piwo, napoje bezalkoholowe, mleko i przetwory mleczne, przetwory owocowo-warzywne, sosy i dresingi, majonez, musztarda, suplementy diety, Próbki środowiskowe z obszarów produkcji żywności: – popłuczyny Obecność alergennych białek glutenu (gliadyn)\nMetoda immunoenzymatyczna (ELISA) PB-PAZ/M-16 wersja 01 z dnia 01.03.2021 na podstawie instrukcji producenta Riopharm Koncentraty spozywcze, przyprawy, kawa rozpuszczalna, zboza i przetwory zbozowe, pieczywo i wyroby piekarnicze, wyroby i polprodukty ciastkarskie, produkty ziemniaczane i zbozowe, slodycze i wyroby cukiernicze, mieso i przetwory miesne, wyroby garmazeryjne, konserwy, napoje alkoholowe, piwo, napoje bezalkoholowe, mleko i przetwory mleczne, przetwory owocowo-warzywne, sosy i dresingi, majonez, musztarda, suplementy diety, Probki srodowiskowe z obszarow produkcji zywnosci: – popluczyny Obecnosc alergennych bialek glutenu (gliadyn)\nMetoda immunoenzymatyczna (ELISA) PB-PAZ/M-16 wersja 01 z dnia 01.03.2021 na podstawie instrukcji producenta Riopharm","categories":["food","environment","pharma"],"row_index":132,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of allergenic gluten proteins (gliadins)","search_en":"Food concentrates, spices, instant coffee, cereals and cereal products, bread and bakery products, confectionery products and semi-finished products, potato and cereal products, sweets and confectionery, meat and meat products, delicatessen products, canned products, alcoholic beverages, beer, non-alcoholic beverages, milk and milk products, fruit-vegetable preserves, sauces and dressings, mayonnaise, mustard, food supplements, Environmental samples from food production areas: – rinse water Presence of allergenic gluten proteins (gliadins) Enzyme immunoassay method (ELISA) PB-PAZ/M-16 wersja 01 z dnia 01.03.2021 na podstawie instrukcji producenta Riopharm","technique_en":"Enzyme immunoassay method (ELISA)","test_object_en":"Food concentrates, spices, instant coffee, cereals and cereal products, bread and bakery products, confectionery products and semi-finished products, potato and cereal products, sweets and confectionery, meat and meat products, delicatessen products, canned products, alcoholic beverages, beer, non-alcoholic beverages, milk and milk products, fruit-vegetable preserves, sauces and dressings, mayonnaise, mustard, food supplements, Environmental samples from food production areas: – rinse water","search_zh":"酶联免疫吸附法（ELISA） PB-PAZ/M-16 wersja 01 z dnia 01.03.2021 na podstawie instrukcji producenta Riopharm","technique_zh":"酶联免疫吸附法（ELISA）"},{"_id":"6a8369ecaf14b9c0e7b1dca7","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Koncentraty spożywcze, przyprawy, kawa rozpuszczalna, zboża i przetwory zbożowe, pieczywo i wyroby piekarnicze, wyroby i półprodukty ciastkarskie, produkty ziemniaczane i zbożowe, słodycze i wyroby cukiernicze, mięso i przetwory mięsne, wyroby garmażeryjne, konserwy, napoje alkoholowe, piwo, napoje bezalkoholowe, mleko i przetwory mleczne, przetwory owocowo-warzywne, sosy i dresingi, majonez, musztarda, suplementy diety, Próbki środowiskowe z obszarów produkcji żywności: – popłuczyny","methodology":"Zawartość alergennych białek glutenu (gliadyn)","parameters":[{"name":"Zakres","range":"(4 - 80) mg/kg (ppm)"}],"technique":"Metoda immunoenzymatyczna (ELISA)","techniques":["Metoda immunoenzymatyczna (ELISA)"],"computed":[],"activity":"Zawartość alergennych białek glutenu (gliadyn)\nZakres (4 - 80) mg/kg (ppm)\nMetoda immunoenzymatyczna (ELISA)","reference":"PB-PAZ/M-16 wersja 01 z dnia 01.03.2021 na podstawie instrukcji producenta Riopharm","norm_bases":["PB-PAZ/M-16 wersja 01 z dnia 01.03.2021 na podstawie instrukcji producenta Riopharm"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Koncentraty spożywcze, przyprawy, kawa rozpuszczalna, zboża i przetwory zbożowe, pieczywo i wyroby piekarnicze, wyroby i półprodukty ciastkarskie, produkty ziemniaczane i zbożowe, słodycze i wyroby cukiernicze, mięso i przetwory mięsne, wyroby garmażeryjne, konserwy, napoje alkoholowe, piwo, napoje bezalkoholowe, mleko i przetwory mleczne, przetwory owocowo-warzywne, sosy i dresingi, majonez, musztarda, suplementy diety, Próbki środowiskowe z obszarów produkcji żywności: – popłuczyny Zawartość alergennych białek glutenu (gliadyn)\nZakres (4 - 80) mg/kg (ppm)\nMetoda immunoenzymatyczna (ELISA) PB-PAZ/M-16 wersja 01 z dnia 01.03.2021 na podstawie instrukcji producenta Riopharm Koncentraty spozywcze, przyprawy, kawa rozpuszczalna, zboza i przetwory zbozowe, pieczywo i wyroby piekarnicze, wyroby i polprodukty ciastkarskie, produkty ziemniaczane i zbozowe, slodycze i wyroby cukiernicze, mieso i przetwory miesne, wyroby garmazeryjne, konserwy, napoje alkoholowe, piwo, napoje bezalkoholowe, mleko i przetwory mleczne, przetwory owocowo-warzywne, sosy i dresingi, majonez, musztarda, suplementy diety, Probki srodowiskowe z obszarow produkcji zywnosci: – popluczyny Zawartosc alergennych bialek glutenu (gliadyn)\nZakres (4 - 80) mg/kg (ppm)\nMetoda immunoenzymatyczna (ELISA) PB-PAZ/M-16 wersja 01 z dnia 01.03.2021 na podstawie instrukcji producenta Riopharm","categories":["food","environment","pharma"],"row_index":133,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Allergenic gluten protein (gliadin) content","parameters_en":[{"name":"Range","range":"(4 - 80) mg/kg (ppm)"}],"search_en":"Food concentrates, spices, instant coffee, cereals and cereal products, bread and bakery products, confectionery products and semi-finished products, potato and cereal products, sweets and confectionery, meat and meat products, delicatessen products, canned products, alcoholic beverages, beer, non-alcoholic beverages, milk and milk products, fruit-vegetable preserves, sauces and dressings, mayonnaise, mustard, food supplements, Environmental samples from food production areas: – rinse water Allergenic gluten protein (gliadin) content Enzyme immunoassay method (ELISA) Range PB-PAZ/M-16 wersja 01 z dnia 01.03.2021 na podstawie instrukcji producenta Riopharm","technique_en":"Enzyme immunoassay method (ELISA)","test_object_en":"Food concentrates, spices, instant coffee, cereals and cereal products, bread and bakery products, confectionery products and semi-finished products, potato and cereal products, sweets and confectionery, meat and meat products, delicatessen products, canned products, alcoholic beverages, beer, non-alcoholic beverages, milk and milk products, fruit-vegetable preserves, sauces and dressings, mayonnaise, mustard, food supplements, Environmental samples from food production areas: – rinse water","parameters_zh":[{"name":"范围","range":"(4 - 80) mg/kg (ppm)"}],"search_zh":"酶联免疫吸附法（ELISA） 范围 PB-PAZ/M-16 wersja 01 z dnia 01.03.2021 na podstawie instrukcji producenta Riopharm","technique_zh":"酶联免疫吸附法（ELISA）"},{"_id":"6a8369ecaf14b9c0e7b1dca8","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Pasze, Zboża i przetwory zbożowe, żywność mrożona, wyroby garmażeryjne, koncentraty spożywcze, mięso i produkty mięsne, mleko i produkty mleczne, owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-mięsne, ryby i przetwory rybne, jaja i produkty jajeczne, dodatki do żywności, żywność dla dzieci, suplementy diety, cukier, kawa i herbata, przyprawy, oleje, tłuszcze zwierzęce i roślinne, majonez, napoje bezalkoholowe, napoje alkoholowe, słodycze i wyroby cukiernicze, pieczywo i wyroby piekarnicze, wyroby i półprodukty ciastkarskie, zioła, orzechy i bakalie, nasiona roślin oleistych, nasiona roślin strączkowych, grzyby, przetwory i półprzetwory grzybowe, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością: - wymaz","methodology":"Obecność Listeria spp","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność Listeria spp\nMetoda hodowlana z potwierdzeniem biochemicznym","reference":"PN-EN ISO 11290-1:2017-07","norm_bases":["PN-EN ISO 11290-1:2017-07"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pasze, Zboża i przetwory zbożowe, żywność mrożona, wyroby garmażeryjne, koncentraty spożywcze, mięso i produkty mięsne, mleko i produkty mleczne, owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-mięsne, ryby i przetwory rybne, jaja i produkty jajeczne, dodatki do żywności, żywność dla dzieci, suplementy diety, cukier, kawa i herbata, przyprawy, oleje, tłuszcze zwierzęce i roślinne, majonez, napoje bezalkoholowe, napoje alkoholowe, słodycze i wyroby cukiernicze, pieczywo i wyroby piekarnicze, wyroby i półprodukty ciastkarskie, zioła, orzechy i bakalie, nasiona roślin oleistych, nasiona roślin strączkowych, grzyby, przetwory i półprzetwory grzybowe, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością: - wymaz Obecność Listeria spp\nMetoda hodowlana z potwierdzeniem biochemicznym PN-EN ISO 11290-1:2017-07 Pasze, Zboza i przetwory zbozowe, zywnosc mrozona, wyroby garmazeryjne, koncentraty spozywcze, mieso i produkty miesne, mleko i produkty mleczne, owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-miesne, ryby i przetwory rybne, jaja i produkty jajeczne, dodatki do zywnosci, zywnosc dla dzieci, suplementy diety, cukier, kawa i herbata, przyprawy, oleje, tluszcze zwierzece i roslinne, majonez, napoje bezalkoholowe, napoje alkoholowe, slodycze i wyroby cukiernicze, pieczywo i wyroby piekarnicze, wyroby i polprodukty ciastkarskie, ziola, orzechy i bakalie, nasiona roslin oleistych, nasiona roslin straczkowych, grzyby, przetwory i polprzetwory grzybowe, Probki srodowiskowe z obszarow produkcji zywnosci i obrotu zywnoscia: - wymaz Obecnosc Listeria spp\nMetoda hodowlana z potwierdzeniem biochemicznym PN-EN ISO 11290-1:2017-07","categories":["food","microbiology","environment","petro","pharma"],"row_index":134,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of Listeria spp","search_en":"Feed, Cereals and cereal products, frozen food, delicatessen products, food concentrates, meat and meat products, milk and dairy products, fruit and vegetables and fruit, vegetable and vegetable-meat products, fish and fish products, eggs and egg products, food additives, food for children, food supplements, sugar, coffee and tea, spices, oils, animal and vegetable fats, mayonnaise, non-alcoholic beverages, alcoholic beverages, sweets and confectionery, bread and bakery products, pastry products and semi-finished pastry products, herbs, nuts and dried fruit, oilseeds, legume seeds, mushrooms, mushroom products and semi-products, Environmental samples from food production and food trade areas: - swab Presence of Listeria spp Culture method with biochemical confirmation PN-EN ISO 11290-1:2017-07","technique_en":"Culture method with biochemical confirmation","test_object_en":"Feed, Cereals and cereal products, frozen food, delicatessen products, food concentrates, meat and meat products, milk and dairy products, fruit and vegetables and fruit, vegetable and vegetable-meat products, fish and fish products, eggs and egg products, food additives, food for children, food supplements, sugar, coffee and tea, spices, oils, animal and vegetable fats, mayonnaise, non-alcoholic beverages, alcoholic beverages, sweets and confectionery, bread and bakery products, pastry products and semi-finished pastry products, herbs, nuts and dried fruit, oilseeds, legume seeds, mushrooms, mushroom products and semi-products, Environmental samples from food production and food trade areas: - swab","search_zh":"培养法结合生化确认 PN-EN ISO 11290-1:2017-07","technique_zh":"培养法结合生化确认"},{"_id":"6a8369ecaf14b9c0e7b1dca9","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Orzechy i bakalie, nasiona roślin oleistych, nasiona roślin strączkowych, grzyby, zioła","methodology":"Liczba drobnoustrojów w temp. 30 °C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba drobnoustrojów w temp. 30 °C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 4833-1:2013-12+ A1:2022-06","norm_bases":["PN-EN ISO 4833-1:2013-12+ A1:2022-06"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Orzechy i bakalie, nasiona roślin oleistych, nasiona roślin strączkowych, grzyby, zioła Liczba drobnoustrojów w temp. 30 °C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 4833-1:2013-12+ A1:2022-06 Orzechy i bakalie, nasiona roslin oleistych, nasiona roslin straczkowych, grzyby, ziola Liczba drobnoustrojow w temp. 30 °C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 4833-1:2013-12+ A1:2022-06","categories":["microbiology"],"row_index":135,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Microorganism count at 30 °C","search_en":"Nuts and dried fruits, oilseeds, pulses, mushrooms, herbs Microorganism count at 30 °C Plate method (pour plate) PN-EN ISO 4833-1:2013-12+ A1:2022-06","technique_en":"Plate method (pour plate)","test_object_en":"Nuts and dried fruits, oilseeds, pulses, mushrooms, herbs","search_zh":"坚果与果干、油料作物籽实、豆类种子、蕈菌、草药 30 °C 微生物数 平板法（倾注培养） PN-EN ISO 4833-1:2013-12+ A1:2022-06","technique_zh":"平板法（倾注培养）","test_object_zh":"坚果与果干、油料作物籽实、豆类种子、蕈菌、草药","methodology_zh":"30 °C 微生物数"},{"_id":"6a8369ecaf14b9c0e7b1dcaa","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Orzechy i bakalie, nasiona roślin oleistych, nasiona roślin strączkowych, grzyby, zioła","methodology":"Liczba Enterobacteriaceae","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba Enterobacteriaceae\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 21528-2:2017-08","norm_bases":["PN-EN ISO 21528-2:2017-08"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Orzechy i bakalie, nasiona roślin oleistych, nasiona roślin strączkowych, grzyby, zioła Liczba Enterobacteriaceae\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 21528-2:2017-08 Orzechy i bakalie, nasiona roslin oleistych, nasiona roslin straczkowych, grzyby, ziola Liczba Enterobacteriaceae\nMetoda plytkowa (posiew wglebny) PN-EN ISO 21528-2:2017-08","categories":["microbiology"],"row_index":136,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Enterobacteriaceae count","search_en":"Nuts and dried fruits, oilseeds, pulses, mushrooms, herbs Enterobacteriaceae count Plate method (pour plate) PN-EN ISO 21528-2:2017-08","technique_en":"Plate method (pour plate)","test_object_en":"Nuts and dried fruits, oilseeds, pulses, mushrooms, herbs","methodology_zh":"肠杆菌科（Enterobacteriaceae）计数","search_zh":"坚果与果干、油料作物籽实、豆类种子、蕈菌、草药 肠杆菌科（Enterobacteriaceae）计数 平板法（倾注培养） PN-EN ISO 21528-2:2017-08","technique_zh":"平板法（倾注培养）","test_object_zh":"坚果与果干、油料作物籽实、豆类种子、蕈菌、草药"},{"_id":"6a8369ecaf14b9c0e7b1dcab","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Orzechy i bakalie, nasiona roślin oleistych, nasiona roślin strączkowych, grzyby, zioła","methodology":"Liczba β-glukuronidazo-dodatnich, Escherichia coli","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba β-glukuronidazo-dodatnich, Escherichia coli\nMetoda płytkowa (posiew wgłębny)","reference":"PN-ISO 16649-2:2004","norm_bases":["PN-ISO 16649-2:2004"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Orzechy i bakalie, nasiona roślin oleistych, nasiona roślin strączkowych, grzyby, zioła Liczba β-glukuronidazo-dodatnich, Escherichia coli\nMetoda płytkowa (posiew wgłębny) PN-ISO 16649-2:2004 Orzechy i bakalie, nasiona roslin oleistych, nasiona roslin straczkowych, grzyby, ziola Liczba β-glukuronidazo-dodatnich, Escherichia coli\nMetoda plytkowa (posiew wglebny) PN-ISO 16649-2:2004","categories":["microbiology"],"row_index":137,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Count of β-glucuronidase-positive, Escherichia coli","search_en":"Nuts and dried fruits, oilseeds, pulses, mushrooms, herbs Count of β-glucuronidase-positive, Escherichia coli Plate method (pour plate) PN-ISO 16649-2:2004","technique_en":"Plate method (pour plate)","test_object_en":"Nuts and dried fruits, oilseeds, pulses, mushrooms, herbs","search_zh":"坚果与果干、油料作物籽实、豆类种子、蕈菌、草药 β-葡萄糖醛酸酶阳性大肠埃希氏菌计数 平板法（倾注培养） PN-ISO 16649-2:2004","technique_zh":"平板法（倾注培养）","methodology_zh":"β-葡萄糖醛酸酶阳性大肠埃希氏菌计数","test_object_zh":"坚果与果干、油料作物籽实、豆类种子、蕈菌、草药"},{"_id":"6a8369ecaf14b9c0e7b1dcac","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Orzechy i bakalie, nasiona roślin oleistych, nasiona roślin strączkowych, grzyby, zioła","methodology":"Liczba bakterii z grupy coli","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba bakterii z grupy coli\nMetoda płytkowa (posiew wgłębny)","reference":"PN-ISO 4832:2007","norm_bases":["PN-ISO 4832:2007"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Orzechy i bakalie, nasiona roślin oleistych, nasiona roślin strączkowych, grzyby, zioła Liczba bakterii z grupy coli\nMetoda płytkowa (posiew wgłębny) PN-ISO 4832:2007 Orzechy i bakalie, nasiona roslin oleistych, nasiona roslin straczkowych, grzyby, ziola Liczba bakterii z grupy coli\nMetoda plytkowa (posiew wglebny) PN-ISO 4832:2007","categories":["microbiology"],"row_index":138,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Coliform bacteria count","search_en":"Nuts and dried fruits, oilseeds, pulses, mushrooms, herbs Coliform bacteria count Plate method (pour plate) PN-ISO 4832:2007","technique_en":"Plate method (pour plate)","test_object_en":"Nuts and dried fruits, oilseeds, pulses, mushrooms, herbs","search_zh":"坚果与果干、油料作物籽实、豆类种子、蕈菌、草药 大肠菌群计数 平板法（倾注培养） PN-ISO 4832:2007","technique_zh":"平板法（倾注培养）","methodology_zh":"大肠菌群计数","test_object_zh":"坚果与果干、油料作物籽实、豆类种子、蕈菌、草药"},{"_id":"6a8369ecaf14b9c0e7b1dcad","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Orzechy i bakalie, nasiona roślin oleistych, nasiona roślin strączkowych, grzyby, zioła","methodology":"Liczba przypuszczalnych Bacillus cereus","parameters":[],"technique":"Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda płytkowa (posiew powierzchniowy)"],"computed":[],"activity":"Liczba przypuszczalnych Bacillus cereus\nMetoda płytkowa (posiew powierzchniowy)","reference":"PN-EN ISO 7932:2005+A1:2020-09 z wyłączeniem pkt. 9.5","norm_bases":["PN-EN ISO 7932:2005+A1:2020-09 z wyłączeniem pkt. 9.5"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Orzechy i bakalie, nasiona roślin oleistych, nasiona roślin strączkowych, grzyby, zioła Liczba przypuszczalnych Bacillus cereus\nMetoda płytkowa (posiew powierzchniowy) PN-EN ISO 7932:2005+A1:2020-09 z wyłączeniem pkt. 9.5 Orzechy i bakalie, nasiona roslin oleistych, nasiona roslin straczkowych, grzyby, ziola Liczba przypuszczalnych Bacillus cereus\nMetoda plytkowa (posiew powierzchniowy) PN-EN ISO 7932:2005+A1:2020-09 z wylaczeniem pkt. 9.5","categories":["microbiology"],"row_index":139,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presumptive Bacillus cereus count","search_en":"Nuts and dried fruits, oilseeds, pulses, mushrooms, herbs Presumptive Bacillus cereus count Plate method (spread plate) PN-EN ISO 7932:2005+A1:2020-09 z wyłączeniem pkt. 9.5","technique_en":"Plate method (spread plate)","test_object_en":"Nuts and dried fruits, oilseeds, pulses, mushrooms, herbs","search_zh":"坚果与果干、油料作物籽实、豆类种子、蕈菌、草药 蜡样芽孢杆菌推定计数 平板法（表面涂布） PN-EN ISO 7932:2005+A1:2020-09 z wyłączeniem pkt. 9.5","technique_zh":"平板法（表面涂布）","methodology_zh":"蜡样芽孢杆菌推定计数","test_object_zh":"坚果与果干、油料作物籽实、豆类种子、蕈菌、草药"},{"_id":"6a8369ecaf14b9c0e7b1dcae","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Dodatki do żywności","methodology":"Liczba β-glukuronidazo-dodatnich, Escherichia coli","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba β-glukuronidazo-dodatnich, Escherichia coli\nMetoda płytkowa (posiew wgłębny)","reference":"PN-ISO 16649-2:2004","norm_bases":["PN-ISO 16649-2:2004"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Dodatki do żywności Liczba β-glukuronidazo-dodatnich, Escherichia coli\nMetoda płytkowa (posiew wgłębny) PN-ISO 16649-2:2004 Dodatki do zywnosci Liczba β-glukuronidazo-dodatnich, Escherichia coli\nMetoda plytkowa (posiew wglebny) PN-ISO 16649-2:2004","categories":["food","microbiology"],"row_index":140,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Count of β-glucuronidase-positive, Escherichia coli","search_en":"Food additives Count of β-glucuronidase-positive, Escherichia coli Plate method (pour plate) PN-ISO 16649-2:2004","technique_en":"Plate method (pour plate)","test_object_en":"Food additives","search_zh":"食品添加剂 β-葡萄糖醛酸酶阳性大肠埃希氏菌计数 平板法（倾注培养） PN-ISO 16649-2:2004","technique_zh":"平板法（倾注培养）","methodology_zh":"β-葡萄糖醛酸酶阳性大肠埃希氏菌计数","test_object_zh":"食品添加剂"},{"_id":"6a8369ecaf14b9c0e7b1dcaf","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Dodatki do żywności","methodology":"Liczba bakterii z grupy coli","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba bakterii z grupy coli\nMetoda płytkowa (posiew wgłębny)","reference":"PN-ISO 4832:2007","norm_bases":["PN-ISO 4832:2007"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Dodatki do żywności Liczba bakterii z grupy coli\nMetoda płytkowa (posiew wgłębny) PN-ISO 4832:2007 Dodatki do zywnosci Liczba bakterii z grupy coli\nMetoda plytkowa (posiew wglebny) PN-ISO 4832:2007","categories":["food","microbiology"],"row_index":141,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Coliform bacteria count","search_en":"Food additives Coliform bacteria count Plate method (pour plate) PN-ISO 4832:2007","technique_en":"Plate method (pour plate)","test_object_en":"Food additives","search_zh":"食品添加剂 大肠菌群计数 平板法（倾注培养） PN-ISO 4832:2007","technique_zh":"平板法（倾注培养）","methodology_zh":"大肠菌群计数","test_object_zh":"食品添加剂"},{"_id":"6a8369ecaf14b9c0e7b1dcb0","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Dodatki do żywności","methodology":"Liczba drożdży i pleśni","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba drożdży i pleśni\nMetoda płytkowa (posiew wgłębny)","reference":"PN-ISO 7954:1999","norm_bases":["PN-ISO 7954:1999"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Dodatki do żywności Liczba drożdży i pleśni\nMetoda płytkowa (posiew wgłębny) PN-ISO 7954:1999 Dodatki do zywnosci Liczba drozdzy i plesni\nMetoda plytkowa (posiew wglebny) PN-ISO 7954:1999","categories":["food"],"row_index":142,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Yeast and mould count","search_en":"Food additives Yeast and mould count Plate method (pour plate) PN-ISO 7954:1999","technique_en":"Plate method (pour plate)","test_object_en":"Food additives","methodology_zh":"酵母菌与霉菌计数","search_zh":"食品添加剂 酵母菌与霉菌计数 平板法（倾注培养） PN-ISO 7954:1999","technique_zh":"平板法（倾注培养）","test_object_zh":"食品添加剂"},{"_id":"6a8369ecaf14b9c0e7b1dcb1","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Dodatki do żywności","methodology":"Obecność Salmonella spp","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność Salmonella spp\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PN-EN ISO 6579-1:2017-04 +A1:2020-09","norm_bases":["PN-EN ISO 6579-1:2017-04 +A1:2020-09"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Dodatki do żywności Obecność Salmonella spp\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579-1:2017-04 +A1:2020-09 Dodatki do zywnosci Obecnosc Salmonella spp\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579-1:2017-04 +A1:2020-09","categories":["microbiology","food"],"row_index":143,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of Salmonella spp","search_en":"Food additives Presence of Salmonella spp Culture method with biochemical and serological confirmation PN-EN ISO 6579-1:2017-04 +A1:2020-09","technique_en":"Culture method with biochemical and serological confirmation","test_object_en":"Food additives","search_zh":"食品添加剂 沙门氏菌属（Salmonella spp）的检出 培养法结合生化与血清学确认 PN-EN ISO 6579-1:2017-04 +A1:2020-09","technique_zh":"培养法结合生化与血清学确认","test_object_zh":"食品添加剂","methodology_zh":"沙门氏菌属（Salmonella spp）的检出"},{"_id":"6a8369ecaf14b9c0e7b1dcb2","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Liczba gronkowców koagulazo-dodatnich","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba gronkowców koagulazo-dodatnich\nMetoda filtracji membranowej","reference":"PB-PAZ/M-01 wersja 02 z dnia. 28.07.2020 według wytycznych PZH ZHK:2007","norm_bases":["PB-PAZ/M-01 wersja 02 z dnia. 28.07.2020 według wytycznych PZH ZHK:2007"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Liczba gronkowców koagulazo-dodatnich\nMetoda filtracji membranowej PB-PAZ/M-01 wersja 02 z dnia. 28.07.2020 według wytycznych PZH ZHK:2007 Woda na plywalniach Liczba gronkowcow koagulazo-dodatnich\nMetoda filtracji membranowej PB-PAZ/M-01 wersja 02 z dnia. 28.07.2020 wedlug wytycznych PZH ZHK:2007","categories":["water"],"row_index":144,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Coagulase-positive staphylococci count","search_en":"Swimming pool water Coagulase-positive staphylococci count Membrane filtration method PB-PAZ/M-01 wersja 02 z dnia. 28.07.2020 według wytycznych PZH ZHK:2007","technique_en":"Membrane filtration method","test_object_en":"Swimming pool water","search_zh":"游泳池水 凝固酶阳性葡萄球菌计数 膜过滤法 PB-PAZ/M-01 wersja 02 z dnia. 28.07.2020 według wytycznych PZH ZHK:2007","technique_zh":"膜过滤法","test_object_zh":"游泳池水","methodology_zh":"凝固酶阳性葡萄球菌计数"},{"_id":"6a8369ecaf14b9c0e7b1dcb3","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach)","methodology":"Ogólna liczba mikroorganizmów w 36 °C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w 36 °C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach) Ogólna liczba mikroorganizmów w 36 °C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda (w tym woda na plywalniach) Ogolna liczba mikroorganizmow w 36 °C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":145,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total viable count at 36 °C","search_en":"Water (including swimming pool water) Total viable count at 36 °C Plate method (pour plate) PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water (including swimming pool water)","methodology_zh":"36 °C 微生物总数","search_zh":"水（含游泳池水） 36 °C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水（含游泳池水）"},{"_id":"6a8369ecaf14b9c0e7b1dcb4","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach)","methodology":"Liczba Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach) Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda (w tym woda na plywalniach) Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":146,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Escherichia coli count","search_en":"Water (including swimming pool water) Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water (including swimming pool water)","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"水（含游泳池水） 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水（含游泳池水）"},{"_id":"6a8369ecaf14b9c0e7b1dcb5","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach)","methodology":"Liczba bakterii grupy coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach) Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda (w tym woda na plywalniach) Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":147,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Coliform bacteria count","search_en":"Water (including swimming pool water) Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water (including swimming pool water)","methodology_zh":"大肠菌群计数","search_zh":"水（含游泳池水） 大肠菌群计数 膜过滤法 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水（含游泳池水）"},{"_id":"6a8369ecaf14b9c0e7b1dcb6","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach)","methodology":"Liczba Pseudomonas aeruginosa","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach) Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009 Woda (w tym woda na plywalniach) Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water"],"row_index":148,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Pseudomonas aeruginosa count","search_en":"Water (including swimming pool water) Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009","technique_en":"Membrane filtration method","test_object_en":"Water (including swimming pool water)","methodology_zh":"铜绿假单胞菌计数","search_zh":"水（含游泳池水） 铜绿假单胞菌计数 膜过滤法 PN-EN ISO 16266:2009","technique_zh":"膜过滤法","test_object_zh":"水（含游泳池水）"},{"_id":"6a8369ecaf14b9c0e7b1dcb7","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach)","methodology":"Liczba Legionella sp., Matryca A, Procedura 5 (pożywka A-BCYE), Procedura 7 (pożywka C-GVPC)","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Legionella sp., Matryca A, Procedura 5 (pożywka A-BCYE), Procedura 7 (pożywka C-GVPC)\nMetoda filtracji membranowej","reference":"PN-EN ISO 11731:2017-08+ Ap1:2019-12","norm_bases":["PN-EN ISO 11731:2017-08+ Ap1:2019-12"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach) Liczba Legionella sp., Matryca A, Procedura 5 (pożywka A-BCYE), Procedura 7 (pożywka C-GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08+ Ap1:2019-12 Woda (w tym woda na plywalniach) Liczba Legionella sp., Matryca A, Procedura 5 (pozywka A-BCYE), Procedura 7 (pozywka C-GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08+ Ap1:2019-12","categories":["microbiology","water"],"row_index":149,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Legionella sp. count, Matrix A, Procedure 5 (medium A-BCYE), Procedure 7 (medium C-GVPC)","search_en":"Water (including swimming pool water) Legionella sp. count, Matrix A, Procedure 5 (medium A-BCYE), Procedure 7 (medium C-GVPC) Membrane filtration method PN-EN ISO 11731:2017-08+ Ap1:2019-12","technique_en":"Membrane filtration method","test_object_en":"Water (including swimming pool water)","search_zh":"水（含游泳池水） 膜过滤法 PN-EN ISO 11731:2017-08+ Ap1:2019-12","technique_zh":"膜过滤法","test_object_zh":"水（含游泳池水）"},{"_id":"6a8369ecaf14b9c0e7b1dcb8","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda","methodology":"Ogólna liczba mikroorganizmów w 22 °C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w 22 °C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Ogólna liczba mikroorganizmów w 22 °C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda Ogolna liczba mikroorganizmow w 22 °C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":150,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total viable count at 22 °C","search_en":"Water Total viable count at 22 °C Plate method (pour plate) PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water","methodology_zh":"22 °C 微生物总数","search_zh":"水 22 °C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水"},{"_id":"6a8369ecaf14b9c0e7b1dcb9","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda","methodology":"Liczba enterokoków kałowych","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba enterokoków kałowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Liczba enterokoków kałowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda Liczba enterokokow kalowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":151,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Intestinal enterococci count","search_en":"Water Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004","technique_en":"Membrane filtration method","test_object_en":"Water","methodology_zh":"粪肠球菌计数","search_zh":"水 粪肠球菌计数 膜过滤法 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"水"},{"_id":"6a8369ecaf14b9c0e7b1dcba","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda","methodology":"Liczba Clostridium perfringens (łącznie ze sporami)","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Clostridium perfringens (łącznie ze sporami)\nMetoda filtracji membranowej","reference":"PN-EN ISO 14189:2016-10","norm_bases":["PN-EN ISO 14189:2016-10"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Liczba Clostridium perfringens (łącznie ze sporami)\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10 Woda Liczba Clostridium perfringens (lacznie ze sporami)\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10","categories":["water"],"row_index":152,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Clostridium perfringens count (including spores)","search_en":"Water Clostridium perfringens count (including spores) Membrane filtration method PN-EN ISO 14189:2016-10","technique_en":"Membrane filtration method","test_object_en":"Water","search_zh":"水 产气荚膜梭菌计数（含芽孢） 膜过滤法 PN-EN ISO 14189:2016-10","technique_zh":"膜过滤法","test_object_zh":"水","methodology_zh":"产气荚膜梭菌计数（含芽孢）"},{"_id":"6a8369ecaf14b9c0e7b1dcbb","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda","methodology":"Liczba przetrwalników beztlenowców redukujących siarczyny (clostridia)","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba przetrwalników beztlenowców redukujących siarczyny (clostridia)\nMetoda filtracji membranowej","reference":"PN-EN 26461-2:2001","norm_bases":["PN-EN 26461-2:2001"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Liczba przetrwalników beztlenowców redukujących siarczyny (clostridia)\nMetoda filtracji membranowej PN-EN 26461-2:2001 Woda Liczba przetrwalnikow beztlenowcow redukujacych siarczyny (clostridia)\nMetoda filtracji membranowej PN-EN 26461-2:2001","categories":["water"],"row_index":153,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Count of spores of sulphite-reducing anaerobes (clostridia)","search_en":"Water Count of spores of sulphite-reducing anaerobes (clostridia) Membrane filtration method PN-EN 26461-2:2001","technique_en":"Membrane filtration method","test_object_en":"Water","search_zh":"水 亚硫酸盐还原厌氧菌（梭菌）芽孢计数 膜过滤法 PN-EN 26461-2:2001","technique_zh":"膜过滤法","test_object_zh":"水","methodology_zh":"亚硫酸盐还原厌氧菌（梭菌）芽孢计数"},{"_id":"6a8369ecaf14b9c0e7b1dcbc","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Tusze zwierząt rzeźnych wymaz","methodology":"Obecność Salmonella spp","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność Salmonella spp\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PN-EN ISO 6579-1:2017-04 +A1:2020-09","norm_bases":["PN-EN ISO 6579-1:2017-04 +A1:2020-09"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Tusze zwierząt rzeźnych wymaz Obecność Salmonella spp\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579-1:2017-04 +A1:2020-09 Tusze zwierzat rzeznych wymaz Obecnosc Salmonella spp\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579-1:2017-04 +A1:2020-09","categories":["microbiology"],"row_index":154,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of Salmonella spp","search_en":"Carcasses of slaughter animals swab Presence of Salmonella spp Culture method with biochemical and serological confirmation PN-EN ISO 6579-1:2017-04 +A1:2020-09","technique_en":"Culture method with biochemical and serological confirmation","test_object_en":"Carcasses of slaughter animals swab","search_zh":"沙门氏菌属（Salmonella spp）的检出 培养法结合生化与血清学确认 PN-EN ISO 6579-1:2017-04 +A1:2020-09","technique_zh":"培养法结合生化与血清学确认","methodology_zh":"沙门氏菌属（Salmonella spp）的检出"},{"_id":"6a8369ecaf14b9c0e7b1dcbd","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Tusze zwierząt rzeźnych - wymaz - wycinki","methodology":"Liczba drobnoustrojów w temp. 30 °C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba drobnoustrojów w temp. 30 °C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 4833-1:2013-12 +A1:2022-06","norm_bases":["PN-EN ISO 4833-1:2013-12 +A1:2022-06"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Tusze zwierząt rzeźnych - wymaz - wycinki Liczba drobnoustrojów w temp. 30 °C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 4833-1:2013-12 +A1:2022-06 Tusze zwierzat rzeznych - wymaz - wycinki Liczba drobnoustrojow w temp. 30 °C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 4833-1:2013-12 +A1:2022-06","categories":["microbiology"],"row_index":155,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Microorganism count at 30 °C","search_en":"Slaughter animal carcasses - swab - excised samples Microorganism count at 30 °C Plate method (pour plate) PN-EN ISO 4833-1:2013-12 +A1:2022-06","technique_en":"Plate method (pour plate)","test_object_en":"Slaughter animal carcasses - swab - excised samples","search_zh":"30 °C 微生物数 平板法（倾注培养） PN-EN ISO 4833-1:2013-12 +A1:2022-06","technique_zh":"平板法（倾注培养）","methodology_zh":"30 °C 微生物数"},{"_id":"6a8369ecaf14b9c0e7b1dcbe","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Tusze zwierząt rzeźnych - wymaz - wycinki","methodology":"Liczba Enterobacteriaceae","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba Enterobacteriaceae\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 21528-2:2017-08","norm_bases":["PN-EN ISO 21528-2:2017-08"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Tusze zwierząt rzeźnych - wymaz - wycinki Liczba Enterobacteriaceae\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 21528-2:2017-08 Tusze zwierzat rzeznych - wymaz - wycinki Liczba Enterobacteriaceae\nMetoda plytkowa (posiew wglebny) PN-EN ISO 21528-2:2017-08","categories":["other"],"row_index":156,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Enterobacteriaceae count","search_en":"Slaughter animal carcasses - swab - excised samples Enterobacteriaceae count Plate method (pour plate) PN-EN ISO 21528-2:2017-08","technique_en":"Plate method (pour plate)","test_object_en":"Slaughter animal carcasses - swab - excised samples","methodology_zh":"肠杆菌科（Enterobacteriaceae）计数","search_zh":"肠杆菌科（Enterobacteriaceae）计数 平板法（倾注培养） PN-EN ISO 21528-2:2017-08","technique_zh":"平板法（倾注培养）"},{"_id":"6a8369ecaf14b9c0e7b1dcbf","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Kosmetyki","methodology":"Badanie skuteczność konserwacji – test konserwacji","parameters":[],"technique":"Metoda płytkowa","techniques":["Metoda płytkowa"],"computed":[],"activity":"Badanie skuteczność konserwacji – test konserwacji\nMetoda płytkowa","reference":"PN-EN ISO 11930:2019-03 +A1:2023-02","norm_bases":["PN-EN ISO 11930:2019-03 +A1:2023-02"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kosmetyki Badanie skuteczność konserwacji – test konserwacji\nMetoda płytkowa PN-EN ISO 11930:2019-03 +A1:2023-02 Kosmetyki Badanie skutecznosc konserwacji – test konserwacji\nMetoda plytkowa PN-EN ISO 11930:2019-03 +A1:2023-02","categories":["pharma"],"row_index":157,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Preservation efficacy testing – preservative challenge test","search_en":"Cosmetics Preservation efficacy testing – preservative challenge test Plate method PN-EN ISO 11930:2019-03 +A1:2023-02","technique_en":"Plate method","test_object_en":"Cosmetics","search_zh":"化妆品 平板法 PN-EN ISO 11930:2019-03 +A1:2023-02","technique_zh":"平板法","test_object_zh":"化妆品"},{"_id":"6a8369ecaf14b9c0e7b1dcc0","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Kosmetyki i surowce kosmetyczne, chemia gospodarcza","methodology":"Obecność Pseudomonas aeruginosa","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność Pseudomonas aeruginosa\nMetoda hodowlana z potwierdzeniem biochemicznym","reference":"PN-EN ISO 22717:2016-01 +A1:2023-03","norm_bases":["PN-EN ISO 22717:2016-01 +A1:2023-03"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kosmetyki i surowce kosmetyczne, chemia gospodarcza Obecność Pseudomonas aeruginosa\nMetoda hodowlana z potwierdzeniem biochemicznym PN-EN ISO 22717:2016-01 +A1:2023-03 Kosmetyki i surowce kosmetyczne, chemia gospodarcza Obecnosc Pseudomonas aeruginosa\nMetoda hodowlana z potwierdzeniem biochemicznym PN-EN ISO 22717:2016-01 +A1:2023-03","categories":["pharma"],"row_index":158,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of Pseudomonas aeruginosa","search_en":"Cosmetics and cosmetic raw materials, household chemicals Presence of Pseudomonas aeruginosa Culture method with biochemical confirmation PN-EN ISO 22717:2016-01 +A1:2023-03","technique_en":"Culture method with biochemical confirmation","test_object_en":"Cosmetics and cosmetic raw materials, household chemicals","methodology_zh":"铜绿假单胞菌（Pseudomonas aeruginosa）检出","search_zh":"化妆品与化妆品原料、家用化学品 铜绿假单胞菌（Pseudomonas aeruginosa）检出 培养法结合生化确认 PN-EN ISO 22717:2016-01 +A1:2023-03","technique_zh":"培养法结合生化确认","test_object_zh":"化妆品与化妆品原料、家用化学品"},{"_id":"6a8369ecaf14b9c0e7b1dcc1","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Kosmetyki i surowce kosmetyczne, chemia gospodarcza","methodology":"Obecność Staphylococcus aureus","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność Staphylococcus aureus\nMetoda hodowlana z potwierdzeniem biochemicznym","reference":"PN-EN ISO 22718:2016-01 +A1:2023-01","norm_bases":["PN-EN ISO 22718:2016-01 +A1:2023-01"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kosmetyki i surowce kosmetyczne, chemia gospodarcza Obecność Staphylococcus aureus\nMetoda hodowlana z potwierdzeniem biochemicznym PN-EN ISO 22718:2016-01 +A1:2023-01 Kosmetyki i surowce kosmetyczne, chemia gospodarcza Obecnosc Staphylococcus aureus\nMetoda hodowlana z potwierdzeniem biochemicznym PN-EN ISO 22718:2016-01 +A1:2023-01","categories":["pharma"],"row_index":159,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of Staphylococcus aureus","search_en":"Cosmetics and cosmetic raw materials, household chemicals Presence of Staphylococcus aureus Culture method with biochemical confirmation PN-EN ISO 22718:2016-01 +A1:2023-01","technique_en":"Culture method with biochemical confirmation","test_object_en":"Cosmetics and cosmetic raw materials, household chemicals","methodology_zh":"金黄色葡萄球菌（Staphylococcus aureus）检出","search_zh":"化妆品与化妆品原料、家用化学品 金黄色葡萄球菌（Staphylococcus aureus）检出 培养法结合生化确认 PN-EN ISO 22718:2016-01 +A1:2023-01","technique_zh":"培养法结合生化确认","test_object_zh":"化妆品与化妆品原料、家用化学品"},{"_id":"6a8369ecaf14b9c0e7b1dcc2","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Kosmetyki i surowce kosmetyczne, chemia gospodarcza","methodology":"Obecność Escherichia coli","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność Escherichia coli\nMetoda hodowlana z potwierdzeniem biochemicznym","reference":"PN-EN ISO 21150:2016-01 +A1:2023-03","norm_bases":["PN-EN ISO 21150:2016-01 +A1:2023-03"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kosmetyki i surowce kosmetyczne, chemia gospodarcza Obecność Escherichia coli\nMetoda hodowlana z potwierdzeniem biochemicznym PN-EN ISO 21150:2016-01 +A1:2023-03 Kosmetyki i surowce kosmetyczne, chemia gospodarcza Obecnosc Escherichia coli\nMetoda hodowlana z potwierdzeniem biochemicznym PN-EN ISO 21150:2016-01 +A1:2023-03","categories":["microbiology","pharma"],"row_index":160,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of Escherichia coli","search_en":"Cosmetics and cosmetic raw materials, household chemicals Presence of Escherichia coli Culture method with biochemical confirmation PN-EN ISO 21150:2016-01 +A1:2023-03","technique_en":"Culture method with biochemical confirmation","test_object_en":"Cosmetics and cosmetic raw materials, household chemicals","methodology_zh":"大肠埃希氏菌（Escherichia coli）检出","search_zh":"化妆品与化妆品原料、家用化学品 大肠埃希氏菌（Escherichia coli）检出 培养法结合生化确认 PN-EN ISO 21150:2016-01 +A1:2023-03","technique_zh":"培养法结合生化确认","test_object_zh":"化妆品与化妆品原料、家用化学品"},{"_id":"6a8369ecaf14b9c0e7b1dcc3","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Kosmetyki i surowce kosmetyczne, chemia gospodarcza","methodology":"Liczba tlenowych bakterii mezofilnych","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba tlenowych bakterii mezofilnych\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 21149:2017 07 +A1:2023-01","norm_bases":["PN-EN ISO 21149:2017 07 +A1:2023-01"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kosmetyki i surowce kosmetyczne, chemia gospodarcza Liczba tlenowych bakterii mezofilnych\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 21149:2017 07 +A1:2023-01 Kosmetyki i surowce kosmetyczne, chemia gospodarcza Liczba tlenowych bakterii mezofilnych\nMetoda plytkowa (posiew wglebny) PN-EN ISO 21149:2017 07 +A1:2023-01","categories":["microbiology","pharma"],"row_index":161,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Count of aerobic mesophilic bacteria","search_en":"Cosmetics and cosmetic raw materials, household chemicals Count of aerobic mesophilic bacteria Plate method (pour plate) PN-EN ISO 21149:2017 07 +A1:2023-01","technique_en":"Plate method (pour plate)","test_object_en":"Cosmetics and cosmetic raw materials, household chemicals","search_zh":"化妆品与化妆品原料、家用化学品 平板法（倾注培养） PN-EN ISO 21149:2017 07 +A1:2023-01","technique_zh":"平板法（倾注培养）","test_object_zh":"化妆品与化妆品原料、家用化学品"},{"_id":"6a8369ecaf14b9c0e7b1dcc4","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Kosmetyki i surowce kosmetyczne, chemia gospodarcza","methodology":"Liczba drożdży i pleśni","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba drożdży i pleśni\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 16212:2017-08 +A1:2023-01","norm_bases":["PN-EN ISO 16212:2017-08 +A1:2023-01"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kosmetyki i surowce kosmetyczne, chemia gospodarcza Liczba drożdży i pleśni\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 16212:2017-08 +A1:2023-01 Kosmetyki i surowce kosmetyczne, chemia gospodarcza Liczba drozdzy i plesni\nMetoda plytkowa (posiew wglebny) PN-EN ISO 16212:2017-08 +A1:2023-01","categories":["pharma"],"row_index":162,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Yeast and mould count","search_en":"Cosmetics and cosmetic raw materials, household chemicals Yeast and mould count Plate method (pour plate) PN-EN ISO 16212:2017-08 +A1:2023-01","technique_en":"Plate method (pour plate)","test_object_en":"Cosmetics and cosmetic raw materials, household chemicals","methodology_zh":"酵母菌与霉菌计数","search_zh":"化妆品与化妆品原料、家用化学品 酵母菌与霉菌计数 平板法（倾注培养） PN-EN ISO 16212:2017-08 +A1:2023-01","technique_zh":"平板法（倾注培养）","test_object_zh":"化妆品与化妆品原料、家用化学品"},{"_id":"6a8369ecaf14b9c0e7b1dcc5","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Kosmetyki i surowce kosmetyczne, chemia gospodarcza","methodology":"Ogólna liczba drobnoustrojów (Liczba tlenowych bakterii mezofilnych, liczba drożdży i pleśni)","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba drobnoustrojów (Liczba tlenowych bakterii mezofilnych, liczba drożdży i pleśni)\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 21149:2017 07 +A1:2023-01 | PN-EN ISO 16212:2017-08","norm_bases":["PN-EN ISO 21149:2017 07 +A1:2023-01","PN-EN ISO 16212:2017-08"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kosmetyki i surowce kosmetyczne, chemia gospodarcza Ogólna liczba drobnoustrojów (Liczba tlenowych bakterii mezofilnych, liczba drożdży i pleśni)\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 21149:2017 07 +A1:2023-01 | PN-EN ISO 16212:2017-08 Kosmetyki i surowce kosmetyczne, chemia gospodarcza Ogolna liczba drobnoustrojow (Liczba tlenowych bakterii mezofilnych, liczba drozdzy i plesni)\nMetoda plytkowa (posiew wglebny) PN-EN ISO 21149:2017 07 +A1:2023-01 | PN-EN ISO 16212:2017-08","categories":["microbiology","pharma"],"row_index":163,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total viable count (Count of aerobic mesophilic bacteria, count of yeasts and moulds)","search_en":"Cosmetics and cosmetic raw materials, household chemicals Total viable count (Count of aerobic mesophilic bacteria, count of yeasts and moulds) Plate method (pour plate) PN-EN ISO 21149:2017 07 +A1:2023-01 | PN-EN ISO 16212:2017-08","technique_en":"Plate method (pour plate)","test_object_en":"Cosmetics and cosmetic raw materials, household chemicals","search_zh":"化妆品与化妆品原料、家用化学品 平板法（倾注培养） PN-EN ISO 21149:2017 07 +A1:2023-01 | PN-EN ISO 16212:2017-08","technique_zh":"平板法（倾注培养）","test_object_zh":"化妆品与化妆品原料、家用化学品"},{"_id":"6a8369ecaf14b9c0e7b1dcc6","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Kosmetyki i surowce kosmetyczne, chemia gospodarcza","methodology":"Obecność Candida albicans","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność Candida albicans\nMetoda hodowlana z potwierdzeniem biochemicznym","reference":"PN-EN ISO 18416:2016-01 +A1:2023-03","norm_bases":["PN-EN ISO 18416:2016-01 +A1:2023-03"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kosmetyki i surowce kosmetyczne, chemia gospodarcza Obecność Candida albicans\nMetoda hodowlana z potwierdzeniem biochemicznym PN-EN ISO 18416:2016-01 +A1:2023-03 Kosmetyki i surowce kosmetyczne, chemia gospodarcza Obecnosc Candida albicans\nMetoda hodowlana z potwierdzeniem biochemicznym PN-EN ISO 18416:2016-01 +A1:2023-03","categories":["pharma"],"row_index":164,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of Candida albicans","search_en":"Cosmetics and cosmetic raw materials, household chemicals Presence of Candida albicans Culture method with biochemical confirmation PN-EN ISO 18416:2016-01 +A1:2023-03","technique_en":"Culture method with biochemical confirmation","test_object_en":"Cosmetics and cosmetic raw materials, household chemicals","methodology_zh":"白色念珠菌（Candida albicans）检出","search_zh":"化妆品与化妆品原料、家用化学品 白色念珠菌（Candida albicans）检出 培养法结合生化确认 PN-EN ISO 18416:2016-01 +A1:2023-03","technique_zh":"培养法结合生化确认","test_object_zh":"化妆品与化妆品原料、家用化学品"},{"_id":"6a8369ecaf14b9c0e7b1dcc7","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Próbki środowiskowe z powierzchni z obszaru produkcji i obrotu żywnością: - odciski z powierzchni","methodology":"Liczba drobnoustrojów tlenowych","parameters":[],"technique":"Metoda płytek kontaktowych","techniques":["Metoda płytek kontaktowych"],"computed":[],"activity":"Liczba drobnoustrojów tlenowych\nMetoda płytek kontaktowych","reference":"PB-PAZ/M-11 wersja 01 z dnia 01.03.2021 r.","norm_bases":["PB-PAZ/M-11 wersja 01 z dnia 01.03.2021 r."],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Próbki środowiskowe z powierzchni z obszaru produkcji i obrotu żywnością: - odciski z powierzchni Liczba drobnoustrojów tlenowych\nMetoda płytek kontaktowych PB-PAZ/M-11 wersja 01 z dnia 01.03.2021 r. Probki srodowiskowe z powierzchni z obszaru produkcji i obrotu zywnoscia: - odciski z powierzchni Liczba drobnoustrojow tlenowych\nMetoda plytek kontaktowych PB-PAZ/M-11 wersja 01 z dnia 01.03.2021 r.","categories":["food","environment","microbiology"],"row_index":165,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Aerobic microorganism count","search_en":"Environmental surface samples from the food production and trade area: - surface imprints Aerobic microorganism count Contact plate method PB-PAZ/M-11 wersja 01 z dnia 01.03.2021 r.","technique_en":"Contact plate method","test_object_en":"Environmental surface samples from the food production and trade area: - surface imprints","search_zh":"需氧菌数 接触平皿法 PB-PAZ/M-11 wersja 01 z dnia 01.03.2021 r.","technique_zh":"接触平皿法","methodology_zh":"需氧菌数"},{"_id":"6a8369ecaf14b9c0e7b1dcc8","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Próbki środowiskowe z powierzchni z obszaru produkcji i obrotu żywnością: - odciski z powierzchni","methodology":"Liczba drożdży i pleśni","parameters":[],"technique":"Metoda płytek kontaktowych","techniques":["Metoda płytek kontaktowych"],"computed":[],"activity":"Liczba drożdży i pleśni\nMetoda płytek kontaktowych","reference":"PB-PAZ/M-11 wersja 01 z dnia 01.03.2021 r.","norm_bases":["PB-PAZ/M-11 wersja 01 z dnia 01.03.2021 r."],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Próbki środowiskowe z powierzchni z obszaru produkcji i obrotu żywnością: - odciski z powierzchni Liczba drożdży i pleśni\nMetoda płytek kontaktowych PB-PAZ/M-11 wersja 01 z dnia 01.03.2021 r. Probki srodowiskowe z powierzchni z obszaru produkcji i obrotu zywnoscia: - odciski z powierzchni Liczba drozdzy i plesni\nMetoda plytek kontaktowych PB-PAZ/M-11 wersja 01 z dnia 01.03.2021 r.","categories":["food","environment"],"row_index":166,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Yeast and mould count","search_en":"Environmental surface samples from the food production and trade area: - surface imprints Yeast and mould count Contact plate method PB-PAZ/M-11 wersja 01 z dnia 01.03.2021 r.","technique_en":"Contact plate method","test_object_en":"Environmental surface samples from the food production and trade area: - surface imprints","methodology_zh":"酵母菌与霉菌计数","search_zh":"酵母菌与霉菌计数 接触平皿法 PB-PAZ/M-11 wersja 01 z dnia 01.03.2021 r.","technique_zh":"接触平皿法"},{"_id":"6a8369ecaf14b9c0e7b1dcc9","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Próbki środowiskowe z powierzchni z obszaru produkcji i obrotu żywnością: - odciski z powierzchni","methodology":"Liczba Enterobacteriaceae","parameters":[],"technique":"Metoda płytek kontaktowych","techniques":["Metoda płytek kontaktowych"],"computed":[],"activity":"Liczba Enterobacteriaceae\nMetoda płytek kontaktowych","reference":"PB-PAZ/M-11 wersja 01 z dnia 01.03.2021 r.","norm_bases":["PB-PAZ/M-11 wersja 01 z dnia 01.03.2021 r."],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Próbki środowiskowe z powierzchni z obszaru produkcji i obrotu żywnością: - odciski z powierzchni Liczba Enterobacteriaceae\nMetoda płytek kontaktowych PB-PAZ/M-11 wersja 01 z dnia 01.03.2021 r. Probki srodowiskowe z powierzchni z obszaru produkcji i obrotu zywnoscia: - odciski z powierzchni Liczba Enterobacteriaceae\nMetoda plytek kontaktowych PB-PAZ/M-11 wersja 01 z dnia 01.03.2021 r.","categories":["food","environment"],"row_index":167,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Enterobacteriaceae count","search_en":"Environmental surface samples from the food production and trade area: - surface imprints Enterobacteriaceae count Contact plate method PB-PAZ/M-11 wersja 01 z dnia 01.03.2021 r.","technique_en":"Contact plate method","test_object_en":"Environmental surface samples from the food production and trade area: - surface imprints","methodology_zh":"肠杆菌科（Enterobacteriaceae）计数","search_zh":"肠杆菌科（Enterobacteriaceae）计数 接触平皿法 PB-PAZ/M-11 wersja 01 z dnia 01.03.2021 r.","technique_zh":"接触平皿法"},{"_id":"6a8369ecaf14b9c0e7b1dcca","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością: - wymaz","methodology":"Liczba Enterobacteriaceae","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba Enterobacteriaceae\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 21528-2:2017-08","norm_bases":["PN-EN ISO 21528-2:2017-08"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością: - wymaz Liczba Enterobacteriaceae\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 21528-2:2017-08 Probki srodowiskowe z obszarow produkcji zywnosci i obrotu zywnoscia: - wymaz Liczba Enterobacteriaceae\nMetoda plytkowa (posiew wglebny) PN-EN ISO 21528-2:2017-08","categories":["food","environment"],"row_index":168,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Enterobacteriaceae count","search_en":"Environmental samples from food production and food trade areas: - swab Enterobacteriaceae count Plate method (pour plate) PN-EN ISO 21528-2:2017-08","technique_en":"Plate method (pour plate)","test_object_en":"Environmental samples from food production and food trade areas: - swab","methodology_zh":"肠杆菌科（Enterobacteriaceae）计数","search_zh":"食品生产与流通场所的环境样品： — 拭子 肠杆菌科（Enterobacteriaceae）计数 平板法（倾注培养） PN-EN ISO 21528-2:2017-08","technique_zh":"平板法（倾注培养）","test_object_zh":"食品生产与流通场所的环境样品： — 拭子"},{"_id":"6a8369ecaf14b9c0e7b1dccb","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością: - wymaz","methodology":"Obecność Listeria monocytogenes","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznymi","techniques":["Metoda hodowlana z potwierdzeniem biochemicznymi"],"computed":[],"activity":"Obecność Listeria monocytogenes\nMetoda hodowlana z potwierdzeniem biochemicznymi","reference":"PN-EN ISO 11290-1:2017-07","norm_bases":["PN-EN ISO 11290-1:2017-07"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością: - wymaz Obecność Listeria monocytogenes\nMetoda hodowlana z potwierdzeniem biochemicznymi PN-EN ISO 11290-1:2017-07 Probki srodowiskowe z obszarow produkcji zywnosci i obrotu zywnoscia: - wymaz Obecnosc Listeria monocytogenes\nMetoda hodowlana z potwierdzeniem biochemicznymi PN-EN ISO 11290-1:2017-07","categories":["food","environment","microbiology"],"row_index":169,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of Listeria monocytogenes","search_en":"Environmental samples from food production and food trade areas: - swab Presence of Listeria monocytogenes Culture method with biochemical confirmation PN-EN ISO 11290-1:2017-07","technique_en":"Culture method with biochemical confirmation","test_object_en":"Environmental samples from food production and food trade areas: - swab","methodology_zh":"单核细胞增生李斯特氏菌的检出","search_zh":"食品生产与流通场所的环境样品： — 拭子 单核细胞增生李斯特氏菌的检出 PN-EN ISO 11290-1:2017-07","test_object_zh":"食品生产与流通场所的环境样品： — 拭子"},{"_id":"6a8369ecaf14b9c0e7b1dccc","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością: - wymaz","methodology":"Liczba drobnoustrojów w temp. 30 °C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba drobnoustrojów w temp. 30 °C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 4833-1:2013-12 +A1:2022-06","norm_bases":["PN-EN ISO 4833-1:2013-12 +A1:2022-06"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością: - wymaz Liczba drobnoustrojów w temp. 30 °C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 4833-1:2013-12 +A1:2022-06 Probki srodowiskowe z obszarow produkcji zywnosci i obrotu zywnoscia: - wymaz Liczba drobnoustrojow w temp. 30 °C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 4833-1:2013-12 +A1:2022-06","categories":["food","environment","microbiology"],"row_index":170,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Microorganism count at 30 °C","search_en":"Environmental samples from food production and food trade areas: - swab Microorganism count at 30 °C Plate method (pour plate) PN-EN ISO 4833-1:2013-12 +A1:2022-06","technique_en":"Plate method (pour plate)","test_object_en":"Environmental samples from food production and food trade areas: - swab","search_zh":"食品生产与流通场所的环境样品： — 拭子 30 °C 微生物数 平板法（倾注培养） PN-EN ISO 4833-1:2013-12 +A1:2022-06","technique_zh":"平板法（倾注培养）","test_object_zh":"食品生产与流通场所的环境样品： — 拭子","methodology_zh":"30 °C 微生物数"},{"_id":"6a8369ecaf14b9c0e7b1dccd","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością: - wymaz","methodology":"Obecność Salmonella spp","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność Salmonella spp\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PN-EN ISO 6579-1:2017-04 +A1:2020-09","norm_bases":["PN-EN ISO 6579-1:2017-04 +A1:2020-09"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością: - wymaz Obecność Salmonella spp\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579-1:2017-04 +A1:2020-09 Probki srodowiskowe z obszarow produkcji zywnosci i obrotu zywnoscia: - wymaz Obecnosc Salmonella spp\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579-1:2017-04 +A1:2020-09","categories":["microbiology","food","environment"],"row_index":171,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of Salmonella spp","search_en":"Environmental samples from food production and food trade areas: - swab Presence of Salmonella spp Culture method with biochemical and serological confirmation PN-EN ISO 6579-1:2017-04 +A1:2020-09","technique_en":"Culture method with biochemical and serological confirmation","test_object_en":"Environmental samples from food production and food trade areas: - swab","search_zh":"食品生产与流通场所的环境样品： — 拭子 沙门氏菌属（Salmonella spp）的检出 培养法结合生化与血清学确认 PN-EN ISO 6579-1:2017-04 +A1:2020-09","technique_zh":"培养法结合生化与血清学确认","test_object_zh":"食品生产与流通场所的环境样品： — 拭子","methodology_zh":"沙门氏菌属（Salmonella spp）的检出"},{"_id":"6a8369ecaf14b9c0e7b1dcce","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością: - wymaz","methodology":"Obecność beztlenowych bakterii przetrwalnikujących i beztlenowych bakterii przetrwalnikujących redukujących siarczany (IV)","parameters":[],"technique":"Metoda hodowlana, probówkowa","techniques":["Metoda hodowlana, probówkowa"],"computed":[],"activity":"Obecność beztlenowych bakterii przetrwalnikujących i beztlenowych bakterii przetrwalnikujących redukujących siarczany (IV)\nMetoda hodowlana, probówkowa","reference":"PB-PAZ/M-10 wersja 01 z dnia 01.03.2021 r.","norm_bases":["PB-PAZ/M-10 wersja 01 z dnia 01.03.2021 r."],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością: - wymaz Obecność beztlenowych bakterii przetrwalnikujących i beztlenowych bakterii przetrwalnikujących redukujących siarczany (IV)\nMetoda hodowlana, probówkowa PB-PAZ/M-10 wersja 01 z dnia 01.03.2021 r. Probki srodowiskowe z obszarow produkcji zywnosci i obrotu zywnoscia: - wymaz Obecnosc beztlenowych bakterii przetrwalnikujacych i beztlenowych bakterii przetrwalnikujacych redukujacych siarczany (IV)\nMetoda hodowlana, probowkowa PB-PAZ/M-10 wersja 01 z dnia 01.03.2021 r.","categories":["food","environment","microbiology"],"row_index":172,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of anaerobic spore-forming bacteria and anaerobic sulfite (IV)-reducing spore-forming bacteria","search_en":"Environmental samples from food production and food trade areas: - swab Presence of anaerobic spore-forming bacteria and anaerobic sulfite (IV)-reducing spore-forming bacteria Culture method, tube PB-PAZ/M-10 wersja 01 z dnia 01.03.2021 r.","technique_en":"Culture method, tube","test_object_en":"Environmental samples from food production and food trade areas: - swab","search_zh":"食品生产与流通场所的环境样品： — 拭子 厌氧芽孢菌与硫酸盐(IV)还原厌氧芽孢菌的检出 试管培养法 PB-PAZ/M-10 wersja 01 z dnia 01.03.2021 r.","test_object_zh":"食品生产与流通场所的环境样品： — 拭子","technique_zh":"试管培养法","methodology_zh":"厌氧芽孢菌与硫酸盐(IV)还原厌氧芽孢菌的检出"},{"_id":"6a8369ecaf14b9c0e7b1dccf","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością: - wymaz","methodology":"Liczba β-glukuronidazo-dodatnich, Escherichia coli","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba β-glukuronidazo-dodatnich, Escherichia coli\nMetoda płytkowa (posiew wgłębny)","reference":"PN-ISO 16649-2:2004","norm_bases":["PN-ISO 16649-2:2004"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością: - wymaz Liczba β-glukuronidazo-dodatnich, Escherichia coli\nMetoda płytkowa (posiew wgłębny) PN-ISO 16649-2:2004 Probki srodowiskowe z obszarow produkcji zywnosci i obrotu zywnoscia: - wymaz Liczba β-glukuronidazo-dodatnich, Escherichia coli\nMetoda plytkowa (posiew wglebny) PN-ISO 16649-2:2004","categories":["food","environment","microbiology"],"row_index":173,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Count of β-glucuronidase-positive, Escherichia coli","search_en":"Environmental samples from food production and food trade areas: - swab Count of β-glucuronidase-positive, Escherichia coli Plate method (pour plate) PN-ISO 16649-2:2004","technique_en":"Plate method (pour plate)","test_object_en":"Environmental samples from food production and food trade areas: - swab","search_zh":"食品生产与流通场所的环境样品： — 拭子 β-葡萄糖醛酸酶阳性大肠埃希氏菌计数 平板法（倾注培养） PN-ISO 16649-2:2004","technique_zh":"平板法（倾注培养）","methodology_zh":"β-葡萄糖醛酸酶阳性大肠埃希氏菌计数","test_object_zh":"食品生产与流通场所的环境样品： — 拭子"},{"_id":"6a8369ecaf14b9c0e7b1dcd0","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością: - wymaz","methodology":"Liczba bakterii z grupy coli","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba bakterii z grupy coli\nMetoda płytkowa (posiew wgłębny)","reference":"PN-ISO 4832:2007","norm_bases":["PN-ISO 4832:2007"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością: - wymaz Liczba bakterii z grupy coli\nMetoda płytkowa (posiew wgłębny) PN-ISO 4832:2007 Probki srodowiskowe z obszarow produkcji zywnosci i obrotu zywnoscia: - wymaz Liczba bakterii z grupy coli\nMetoda plytkowa (posiew wglebny) PN-ISO 4832:2007","categories":["food","environment","microbiology"],"row_index":174,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Coliform bacteria count","search_en":"Environmental samples from food production and food trade areas: - swab Coliform bacteria count Plate method (pour plate) PN-ISO 4832:2007","technique_en":"Plate method (pour plate)","test_object_en":"Environmental samples from food production and food trade areas: - swab","search_zh":"食品生产与流通场所的环境样品： — 拭子 大肠菌群计数 平板法（倾注培养） PN-ISO 4832:2007","technique_zh":"平板法（倾注培养）","methodology_zh":"大肠菌群计数","test_object_zh":"食品生产与流通场所的环境样品： — 拭子"},{"_id":"6a8369ecaf14b9c0e7b1dcd1","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością: - wymaz","methodology":"Liczba gronkowców koagulazo-dodatnich (Staphylococcus aureus i innych gatunków)","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba gronkowców koagulazo-dodatnich (Staphylococcus aureus i innych gatunków)\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6888-2:2022-03 +A1:2024-02","norm_bases":["PN-EN ISO 6888-2:2022-03 +A1:2024-02"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością: - wymaz Liczba gronkowców koagulazo-dodatnich (Staphylococcus aureus i innych gatunków)\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6888-2:2022-03 +A1:2024-02 Probki srodowiskowe z obszarow produkcji zywnosci i obrotu zywnoscia: - wymaz Liczba gronkowcow koagulazo-dodatnich (Staphylococcus aureus i innych gatunkow)\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6888-2:2022-03 +A1:2024-02","categories":["food","environment"],"row_index":175,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Coagulase-positive staphylococci count (Staphylococcus aureus and other species)","search_en":"Environmental samples from food production and food trade areas: - swab Coagulase-positive staphylococci count (Staphylococcus aureus and other species) Plate method (pour plate) PN-EN ISO 6888-2:2022-03 +A1:2024-02","technique_en":"Plate method (pour plate)","test_object_en":"Environmental samples from food production and food trade areas: - swab","search_zh":"食品生产与流通场所的环境样品： — 拭子 凝固酶阳性葡萄球菌数（金黄色葡萄球菌及其他菌种） 平板法（倾注培养） PN-EN ISO 6888-2:2022-03 +A1:2024-02","technique_zh":"平板法（倾注培养）","test_object_zh":"食品生产与流通场所的环境样品： — 拭子","methodology_zh":"凝固酶阳性葡萄球菌数（金黄色葡萄球菌及其他菌种）"},{"_id":"6a8369ecaf14b9c0e7b1dcd2","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością: - wymaz","methodology":"Liczba drożdży i pleśni","parameters":[],"technique":"Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda płytkowa (posiew powierzchniowy)"],"computed":[],"activity":"Liczba drożdży i pleśni\nMetoda płytkowa (posiew powierzchniowy)","reference":"PN-ISO 21527-1:2009","norm_bases":["PN-ISO 21527-1:2009"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością: - wymaz Liczba drożdży i pleśni\nMetoda płytkowa (posiew powierzchniowy) PN-ISO 21527-1:2009 Probki srodowiskowe z obszarow produkcji zywnosci i obrotu zywnoscia: - wymaz Liczba drozdzy i plesni\nMetoda plytkowa (posiew powierzchniowy) PN-ISO 21527-1:2009","categories":["food","environment"],"row_index":176,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Yeast and mould count","search_en":"Environmental samples from food production and food trade areas: - swab Yeast and mould count Plate method (spread plate) PN-ISO 21527-1:2009","technique_en":"Plate method (spread plate)","test_object_en":"Environmental samples from food production and food trade areas: - swab","methodology_zh":"酵母菌与霉菌计数","search_zh":"食品生产与流通场所的环境样品： — 拭子 酵母菌与霉菌计数 平板法（表面涂布） PN-ISO 21527-1:2009","technique_zh":"平板法（表面涂布）","test_object_zh":"食品生产与流通场所的环境样品： — 拭子"},{"_id":"6a8369ecaf14b9c0e7b1dcd3","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Powietrze","methodology":"Liczba drobnoustrojów tlenowych","parameters":[],"technique":"Metoda płytkowa","techniques":["Metoda płytkowa"],"computed":[],"activity":"Liczba drobnoustrojów tlenowych\nMetoda płytkowa","reference":"P B-PAZ/M-14 wersja 01 z dnia 01.03.2021 r.","norm_bases":["P B-PAZ/M-14 wersja 01 z dnia 01.03.2021 r."],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Powietrze Liczba drobnoustrojów tlenowych\nMetoda płytkowa P B-PAZ/M-14 wersja 01 z dnia 01.03.2021 r. Powietrze Liczba drobnoustrojow tlenowych\nMetoda plytkowa P B-PAZ/M-14 wersja 01 z dnia 01.03.2021 r.","categories":["environment","microbiology"],"row_index":177,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Aerobic microorganism count","search_en":"Air Aerobic microorganism count Plate method P B-PAZ/M-14 wersja 01 z dnia 01.03.2021 r.","technique_en":"Plate method","test_object_en":"Air","search_zh":"空气 需氧菌数 平板法 P B-PAZ/M-14 wersja 01 z dnia 01.03.2021 r.","technique_zh":"平板法","test_object_zh":"空气","methodology_zh":"需氧菌数"},{"_id":"6a8369ecaf14b9c0e7b1dcd4","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Powietrze","methodology":"Liczba drożdży i pleśni","parameters":[],"technique":"Metoda płytkowa","techniques":["Metoda płytkowa"],"computed":[],"activity":"Liczba drożdży i pleśni\nMetoda płytkowa","reference":"P B-PAZ/M-14 wersja 01 z dnia 01.03.2021 r.","norm_bases":["P B-PAZ/M-14 wersja 01 z dnia 01.03.2021 r."],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Powietrze Liczba drożdży i pleśni\nMetoda płytkowa P B-PAZ/M-14 wersja 01 z dnia 01.03.2021 r. Powietrze Liczba drozdzy i plesni\nMetoda plytkowa P B-PAZ/M-14 wersja 01 z dnia 01.03.2021 r.","categories":["environment"],"row_index":178,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Yeast and mould count","search_en":"Air Yeast and mould count Plate method P B-PAZ/M-14 wersja 01 z dnia 01.03.2021 r.","technique_en":"Plate method","test_object_en":"Air","methodology_zh":"酵母菌与霉菌计数","search_zh":"空气 酵母菌与霉菌计数 平板法 P B-PAZ/M-14 wersja 01 z dnia 01.03.2021 r.","technique_zh":"平板法","test_object_zh":"空气"},{"_id":"6a8369ecaf14b9c0e7b1dcd5","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Pasze, Kawa i herbata, przyprawy, oleje, tłuszcze zwierzęce i roślinne, zboża i przetwory zbożowe, żywność mrożona, wyroby garmażeryjne, koncentraty spożywcze, mięso i produkty mięsne, mleko i produkty mleczne, napoje (gazowane, niegazowane, soki, syropy), napoje alkoholowe i wyroby spirytusowe, owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-mięsne, ryby i przetwory rybne, słodycze i wyroby cukiernicze, suplementy diety, jaja i produkty jajeczne, owoce morza, wino, wyroby winiarskie, nasiona roślin strączkowych, konserwy, nasiona roślin oleistych, majonez, musztarda, produkty ziemniaczane i zbożowe, sosy i dresingi, bakalie i orzechy, piwo, cukier, pieczywo i wyroby piekarnicze, wyroby i półprodukty ciastkarskie, grzyby, przetwory i półprzetwory grzybowe, zioła, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością: - wymazy","methodology":"Liczba drożdży i pleśni","parameters":[],"technique":"Metoda Petrifilm","techniques":["Metoda Petrifilm"],"computed":[],"activity":"Liczba drożdży i pleśni\nMetoda Petrifilm","reference":"PB-PAZ/M-20 wersja 01 z dnia 1.04.2025 opracowana na podstawie instrukcji producenta płytek 3M Petrifilm RYM","norm_bases":["PB-PAZ/M-20 wersja 01 z dnia 1.04.2025 opracowana na podstawie instrukcji producenta płytek 3M Petrifilm RYM"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pasze, Kawa i herbata, przyprawy, oleje, tłuszcze zwierzęce i roślinne, zboża i przetwory zbożowe, żywność mrożona, wyroby garmażeryjne, koncentraty spożywcze, mięso i produkty mięsne, mleko i produkty mleczne, napoje (gazowane, niegazowane, soki, syropy), napoje alkoholowe i wyroby spirytusowe, owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-mięsne, ryby i przetwory rybne, słodycze i wyroby cukiernicze, suplementy diety, jaja i produkty jajeczne, owoce morza, wino, wyroby winiarskie, nasiona roślin strączkowych, konserwy, nasiona roślin oleistych, majonez, musztarda, produkty ziemniaczane i zbożowe, sosy i dresingi, bakalie i orzechy, piwo, cukier, pieczywo i wyroby piekarnicze, wyroby i półprodukty ciastkarskie, grzyby, przetwory i półprzetwory grzybowe, zioła, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością: - wymazy Liczba drożdży i pleśni\nMetoda Petrifilm PB-PAZ/M-20 wersja 01 z dnia 1.04.2025 opracowana na podstawie instrukcji producenta płytek 3M Petrifilm RYM Pasze, Kawa i herbata, przyprawy, oleje, tluszcze zwierzece i roslinne, zboza i przetwory zbozowe, zywnosc mrozona, wyroby garmazeryjne, koncentraty spozywcze, mieso i produkty miesne, mleko i produkty mleczne, napoje (gazowane, niegazowane, soki, syropy), napoje alkoholowe i wyroby spirytusowe, owoce i warzywa i przetwory owocowe i warzywne oraz warzywno-miesne, ryby i przetwory rybne, slodycze i wyroby cukiernicze, suplementy diety, jaja i produkty jajeczne, owoce morza, wino, wyroby winiarskie, nasiona roslin straczkowych, konserwy, nasiona roslin oleistych, majonez, musztarda, produkty ziemniaczane i zbozowe, sosy i dresingi, bakalie i orzechy, piwo, cukier, pieczywo i wyroby piekarnicze, wyroby i polprodukty ciastkarskie, grzyby, przetwory i polprzetwory grzybowe, ziola, Probki srodowiskowe z obszarow produkcji zywnosci i obrotu zywnoscia: - wymazy Liczba drozdzy i plesni\nMetoda Petrifilm PB-PAZ/M-20 wersja 01 z dnia 1.04.2025 opracowana na podstawie instrukcji producenta plytek 3M Petrifilm RYM","categories":["food","environment","petro","microbiology","pharma"],"row_index":179,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Yeast and mould count","search_en":"Feed, Coffee and tea, spices, oils, animal and vegetable fats, cereals and cereal products, frozen food, delicatessen products, food concentrates, meat and meat products, milk and dairy products, beverages (carbonated, still, juices, syrups), alcoholic beverages and spirit drinks, fruit and vegetables and fruit, vegetable and vegetable-meat products, fish and fish products, sweets and confectionery, food supplements, eggs and egg products, seafood, wine, wine products, legume seeds, canned products, oilseeds, mayonnaise, mustard, potato and cereal products, sauces and dressings, dried fruit and nuts, beer, sugar, bread and bakery products, pastry products and semi-finished pastry products, mushrooms, mushroom products and semi-products, herbs, Environmental samples from food production and food trade areas: - swabs Yeast and mould count Petrifilm method PB-PAZ/M-20 wersja 01 z dnia 1.04.2025 opracowana na podstawie instrukcji producenta płytek 3M Petrifilm RYM","technique_en":"Petrifilm method","test_object_en":"Feed, Coffee and tea, spices, oils, animal and vegetable fats, cereals and cereal products, frozen food, delicatessen products, food concentrates, meat and meat products, milk and dairy products, beverages (carbonated, still, juices, syrups), alcoholic beverages and spirit drinks, fruit and vegetables and fruit, vegetable and vegetable-meat products, fish and fish products, sweets and confectionery, food supplements, eggs and egg products, seafood, wine, wine products, legume seeds, canned products, oilseeds, mayonnaise, mustard, potato and cereal products, sauces and dressings, dried fruit and nuts, beer, sugar, bread and bakery products, pastry products and semi-finished pastry products, mushrooms, mushroom products and semi-products, herbs, Environmental samples from food production and food trade areas: - swabs","methodology_zh":"酵母菌与霉菌计数","search_zh":"酵母菌与霉菌计数 Petrifilm 测试片法 PB-PAZ/M-20 wersja 01 z dnia 1.04.2025 opracowana na podstawie instrukcji producenta płytek 3M Petrifilm RYM","technique_zh":"Petrifilm 测试片法"},{"_id":"6a8369ecaf14b9c0e7b1dcd6","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Mleko i produkty mleczne poddane obróbce termicznej, surowe mięso i produkty mięsne ready-to-cook RTC (z wyjątkiem mięsa drobiowego), produkty mięsne ready-to-eat RTE i ready-to-reheat RTRH (z wyjątkiem produktów z mięsa drobiowego), Surowe mięso drobiowe i produkty, Produkty z mięsa drobiowego ready-, Jaja i produkty jajeczne, Surowe ryby i owoce morza, ryby i (nieprzetworzone), Produkty rybne i owoce morza ready-, Świeże produkty roślinne (w tym owoce, warzywa, świeże przyprawy);, Przetworzone owoce i warzywa, Suszone zboża, owoce, orzechy, nasiona i warzywa, Preparaty do początkowego żywienia niemowląt i płatki zbożowe dla niemowląt, Czekolada, wyroby piekarnicze i cukiernicze, Żywność złożona (wieloskładnikowa) lub składniki posiłków, dania gotowe","methodology":"Liczba gronkowców koagulazo-dodatnich (Staphylococcus aureus i innych gatunków)","parameters":[],"technique":"Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda płytkowa (posiew powierzchniowy)"],"computed":[],"activity":"Liczba gronkowców koagulazo-dodatnich (Staphylococcus aureus i innych gatunków)\nMetoda płytkowa (posiew powierzchniowy)","reference":"PN-EN ISO 6888-1:2022-03 +A1:2024-02","norm_bases":["PN-EN ISO 6888-1:2022-03 +A1:2024-02"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mleko i produkty mleczne poddane obróbce termicznej, surowe mięso i produkty mięsne ready-to-cook RTC (z wyjątkiem mięsa drobiowego), produkty mięsne ready-to-eat RTE i ready-to-reheat RTRH (z wyjątkiem produktów z mięsa drobiowego), Surowe mięso drobiowe i produkty, Produkty z mięsa drobiowego ready-, Jaja i produkty jajeczne, Surowe ryby i owoce morza, ryby i (nieprzetworzone), Produkty rybne i owoce morza ready-, Świeże produkty roślinne (w tym owoce, warzywa, świeże przyprawy);, Przetworzone owoce i warzywa, Suszone zboża, owoce, orzechy, nasiona i warzywa, Preparaty do początkowego żywienia niemowląt i płatki zbożowe dla niemowląt, Czekolada, wyroby piekarnicze i cukiernicze, Żywność złożona (wieloskładnikowa) lub składniki posiłków, dania gotowe Liczba gronkowców koagulazo-dodatnich (Staphylococcus aureus i innych gatunków)\nMetoda płytkowa (posiew powierzchniowy) PN-EN ISO 6888-1:2022-03 +A1:2024-02 Mleko i produkty mleczne poddane obrobce termicznej, surowe mieso i produkty miesne ready-to-cook RTC (z wyjatkiem miesa drobiowego), produkty miesne ready-to-eat RTE i ready-to-reheat RTRH (z wyjatkiem produktow z miesa drobiowego), Surowe mieso drobiowe i produkty, Produkty z miesa drobiowego ready-, Jaja i produkty jajeczne, Surowe ryby i owoce morza, ryby i (nieprzetworzone), Produkty rybne i owoce morza ready-, Swieze produkty roslinne (w tym owoce, warzywa, swieze przyprawy);, Przetworzone owoce i warzywa, Suszone zboza, owoce, orzechy, nasiona i warzywa, Preparaty do poczatkowego zywienia niemowlat i platki zbozowe dla niemowlat, Czekolada, wyroby piekarnicze i cukiernicze, Zywnosc zlozona (wieloskladnikowa) lub skladniki posilkow, dania gotowe Liczba gronkowcow koagulazo-dodatnich (Staphylococcus aureus i innych gatunkow)\nMetoda plytkowa (posiew powierzchniowy) PN-EN ISO 6888-1:2022-03 +A1:2024-02","categories":["food"],"row_index":180,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Coagulase-positive staphylococci count (Staphylococcus aureus and other species)","search_en":"Coagulase-positive staphylococci count (Staphylococcus aureus and other species) Plate method (spread plate) PN-EN ISO 6888-1:2022-03 +A1:2024-02","technique_en":"Plate method (spread plate)","search_zh":"凝固酶阳性葡萄球菌数（金黄色葡萄球菌及其他菌种） 平板法（表面涂布） PN-EN ISO 6888-1:2022-03 +A1:2024-02","technique_zh":"平板法（表面涂布）","methodology_zh":"凝固酶阳性葡萄球菌数（金黄色葡萄球菌及其他菌种）"},{"_id":"6a8369ecaf14b9c0e7b1dcd7","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Żywność E, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością: - wymazy E","methodology":"Obecność przypuszczalnych, Escherichia coli","parameters":[],"technique":"Metoda hodowlana, probówkowa","techniques":["Metoda hodowlana, probówkowa"],"computed":[],"activity":"Obecność przypuszczalnych, Escherichia coli\nMetoda hodowlana, probówkowa","reference":"PN-ISO 7251","norm_bases":["PN-ISO 7251"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością: - wymazy E Obecność przypuszczalnych, Escherichia coli\nMetoda hodowlana, probówkowa PN-ISO 7251 Zywnosc E, Probki srodowiskowe z obszarow produkcji zywnosci i obrotu zywnoscia: - wymazy E Obecnosc przypuszczalnych, Escherichia coli\nMetoda hodowlana, probowkowa PN-ISO 7251","categories":["food","environment","microbiology"],"row_index":181,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of presumptive, Escherichia coli","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Presence of presumptive, Escherichia coli Culture method, tube E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PN-ISO 7251","technique_en":"Culture method, tube","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"疑似大肠埃希氏菌的检出 试管培养法 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PN-ISO 7251","methodology_zh":"疑似大肠埃希氏菌的检出","technique_zh":"试管培养法"},{"_id":"6a8369ecaf14b9c0e7b1dcd8","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Żywność E, Pasze E","methodology":"Liczba drożdży i pleśni","parameters":[],"technique":"Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda płytkowa (posiew powierzchniowy)"],"computed":[],"activity":"Liczba drożdży i pleśni\nMetoda płytkowa (posiew powierzchniowy)","reference":"PN-ISO 21527-1","norm_bases":["PN-ISO 21527-1"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze E Liczba drożdży i pleśni\nMetoda płytkowa (posiew powierzchniowy) PN-ISO 21527-1 Zywnosc E, Pasze E Liczba drozdzy i plesni\nMetoda plytkowa (posiew powierzchniowy) PN-ISO 21527-1","categories":["food"],"row_index":182,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Yeast and mould count","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Food E, Feed E Yeast and mould count Plate method (spread plate) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PN-ISO 21527-1","technique_en":"Plate method (spread plate)","test_object_en":"Food E, Feed E","methodology_zh":"酵母菌与霉菌计数","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"食品 E、饲料 E 酵母菌与霉菌计数 平板法（表面涂布） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PN-ISO 21527-1","technique_zh":"平板法（表面涂布）","test_object_zh":"食品 E、饲料 E"},{"_id":"6a8369ecaf14b9c0e7b1dcd9","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Żywność E, Pasze E","methodology":"Liczba drożdży i pleśni","parameters":[],"technique":"Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda płytkowa (posiew powierzchniowy)"],"computed":[],"activity":"Liczba drożdży i pleśni\nMetoda płytkowa (posiew powierzchniowy)","reference":"PN-ISO 21527-2","norm_bases":["PN-ISO 21527-2"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze E Liczba drożdży i pleśni\nMetoda płytkowa (posiew powierzchniowy) PN-ISO 21527-2 Zywnosc E, Pasze E Liczba drozdzy i plesni\nMetoda plytkowa (posiew powierzchniowy) PN-ISO 21527-2","categories":["food"],"row_index":183,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Yeast and mould count","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Food E, Feed E Yeast and mould count Plate method (spread plate) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PN-ISO 21527-2","technique_en":"Plate method (spread plate)","test_object_en":"Food E, Feed E","methodology_zh":"酵母菌与霉菌计数","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"食品 E、饲料 E 酵母菌与霉菌计数 平板法（表面涂布） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PN-ISO 21527-2","technique_zh":"平板法（表面涂布）","test_object_zh":"食品 E、饲料 E"},{"_id":"6a8369ecaf14b9c0e7b1dcda","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Żywność E, Pasze E","methodology":"Liczba enterokoków kałowych","parameters":[],"technique":"Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda płytkowa (posiew powierzchniowy)"],"computed":[],"activity":"Liczba enterokoków kałowych\nMetoda płytkowa (posiew powierzchniowy)","reference":"PB-PAZ/M-04","norm_bases":["PB-PAZ/M-04"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze E Liczba enterokoków kałowych\nMetoda płytkowa (posiew powierzchniowy) PB-PAZ/M-04 Zywnosc E, Pasze E Liczba enterokokow kalowych\nMetoda plytkowa (posiew powierzchniowy) PB-PAZ/M-04","categories":["food"],"row_index":184,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Intestinal enterococci count","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Food E, Feed E Intestinal enterococci count Plate method (spread plate) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PB-PAZ/M-04","technique_en":"Plate method (spread plate)","test_object_en":"Food E, Feed E","methodology_zh":"粪肠球菌计数","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"食品 E、饲料 E 粪肠球菌计数 平板法（表面涂布） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PB-PAZ/M-04","technique_zh":"平板法（表面涂布）","test_object_zh":"食品 E、饲料 E"},{"_id":"6a8369ecaf14b9c0e7b1dcdb","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Żywność E, Pasze E","methodology":"Obecność gronkowców koagulazo-dodatnich (Staphylococcus aureus i innych gatunków)","parameters":[],"technique":"Metoda hodowlana, probówkowa","techniques":["Metoda hodowlana, probówkowa"],"computed":[],"activity":"Obecność gronkowców koagulazo-dodatnich (Staphylococcus aureus i innych gatunków)\nMetoda hodowlana, probówkowa","reference":"PN-EN ISO 6888-3","norm_bases":["PN-EN ISO 6888-3"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze E Obecność gronkowców koagulazo-dodatnich (Staphylococcus aureus i innych gatunków)\nMetoda hodowlana, probówkowa PN-EN ISO 6888-3 Zywnosc E, Pasze E Obecnosc gronkowcow koagulazo-dodatnich (Staphylococcus aureus i innych gatunkow)\nMetoda hodowlana, probowkowa PN-EN ISO 6888-3","categories":["food"],"row_index":185,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of coagulase-positive staphylococci (Staphylococcus aureus and other species)","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Food E, Feed E Presence of coagulase-positive staphylococci (Staphylococcus aureus and other species) Culture method, tube E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PN-EN ISO 6888-3","technique_en":"Culture method, tube","test_object_en":"Food E, Feed E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"食品 E、饲料 E 凝固酶阳性葡萄球菌（金黄色葡萄球菌及其他菌种）的检出 试管培养法 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PN-EN ISO 6888-3","technique_zh":"试管培养法","test_object_zh":"食品 E、饲料 E","methodology_zh":"凝固酶阳性葡萄球菌（金黄色葡萄球菌及其他菌种）的检出"},{"_id":"6a8369ecaf14b9c0e7b1dcdc","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Żywność E, Pasze E","methodology":"Obecność Salmonella spp","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność Salmonella spp\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PN-EN ISO 6579-1","norm_bases":["PN-EN ISO 6579-1"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze E Obecność Salmonella spp\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579-1 Zywnosc E, Pasze E Obecnosc Salmonella spp\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579-1","categories":["food","microbiology"],"row_index":186,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of Salmonella spp","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Food E, Feed E Presence of Salmonella spp Culture method with biochemical and serological confirmation E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PN-EN ISO 6579-1","technique_en":"Culture method with biochemical and serological confirmation","test_object_en":"Food E, Feed E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"食品 E、饲料 E 沙门氏菌属（Salmonella spp）的检出 培养法结合生化与血清学确认 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PN-EN ISO 6579-1","technique_zh":"培养法结合生化与血清学确认","methodology_zh":"沙门氏菌属（Salmonella spp）的检出","test_object_zh":"食品 E、饲料 E"},{"_id":"6a8369ecaf14b9c0e7b1dcdd","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Żywność E, Pasze E","methodology":"Obecność Listeria monocytogenes","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność Listeria monocytogenes\nMetoda hodowlana z potwierdzeniem biochemicznym","reference":"PN-EN ISO 11290-1","norm_bases":["PN-EN ISO 11290-1"],"lab_section":"Pracownia Badań Żywności, Dział Mikrobiologii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze E Obecność Listeria monocytogenes\nMetoda hodowlana z potwierdzeniem biochemicznym PN-EN ISO 11290-1 Zywnosc E, Pasze E Obecnosc Listeria monocytogenes\nMetoda hodowlana z potwierdzeniem biochemicznym PN-EN ISO 11290-1","categories":["food","microbiology"],"row_index":187,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of Listeria monocytogenes","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Food E, Feed E Presence of Listeria monocytogenes Culture method with biochemical confirmation E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PN-EN ISO 11290-1","technique_en":"Culture method with biochemical confirmation","test_object_en":"Food E, Feed E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"食品 E、饲料 E 单核细胞增生李斯特氏菌的检出 培养法结合生化确认 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PN-EN ISO 11290-1","technique_zh":"培养法结合生化确认","methodology_zh":"单核细胞增生李斯特氏菌的检出","test_object_zh":"食品 E、饲料 E"},{"_id":"6a8369ecaf14b9c0e7b1dcde","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością","methodology":"Zapach, smak przekazywany przy bezpośrednim kontakcie","parameters":[{"name":"Zakres","range":"0 – 4"}],"technique":"Metoda multiporównawcza","techniques":["Metoda multiporównawcza"],"computed":[],"activity":"Zapach, smak przekazywany przy bezpośrednim kontakcie\nZakres 0 – 4\nMetoda multiporównawcza","reference":"DIN 10955:2024-01","norm_bases":["DIN 10955:2024-01"],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością Zapach, smak przekazywany przy bezpośrednim kontakcie\nZakres 0 – 4\nMetoda multiporównawcza DIN 10955:2024-01 Materialy i wyroby z tworzyw sztucznych przeznaczone do kontaktu z zywnoscia Zapach, smak przekazywany przy bezposrednim kontakcie\nZakres 0 – 4\nMetoda multiporownawcza DIN 10955:2024-01","categories":["materials","food"],"row_index":188,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Odour, taste imparted on direct contact","parameters_en":[{"name":"Range","range":"0 – 4"}],"search_en":"Plastic materials and articles intended to come into contact with food Odour, taste imparted on direct contact Multi-comparative method Range DIN 10955:2024-01","technique_en":"Multi-comparative method","test_object_en":"Plastic materials and articles intended to come into contact with food","parameters_zh":[{"name":"范围","range":"0 – 4"}],"search_zh":"拟与食品接触的塑料材料及制品 多重比较法 范围 DIN 10955:2024-01","test_object_zh":"拟与食品接触的塑料材料及制品","technique_zh":"多重比较法"},{"_id":"6a8369ecaf14b9c0e7b1dcdf","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Wyroby cukiernicze, Wyroby ciastkarskie","methodology":"Zawartość kuwertury","parameters":[{"name":"Zakres","range":"(5 - 40) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość kuwertury\nZakres (5 - 40) %\nMetoda wagowa","reference":"PB-PAZ/FS-21 wersja 01 z dnia 22.02.2021 r.","norm_bases":["PB-PAZ/FS-21 wersja 01 z dnia 22.02.2021 r."],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby cukiernicze, Wyroby ciastkarskie Zawartość kuwertury\nZakres (5 - 40) %\nMetoda wagowa PB-PAZ/FS-21 wersja 01 z dnia 22.02.2021 r. Wyroby cukiernicze, Wyroby ciastkarskie Zawartosc kuwertury\nZakres (5 - 40) %\nMetoda wagowa PB-PAZ/FS-21 wersja 01 z dnia 22.02.2021 r.","categories":["food"],"row_index":189,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Couverture content","parameters_en":[{"name":"Range","range":"(5 - 40) %"}],"search_en":"Confectionery products, Pastry products Couverture content Gravimetric method Range PB-PAZ/FS-21 wersja 01 z dnia 22.02.2021 r.","technique_en":"Gravimetric method","test_object_en":"Confectionery products, Pastry products","parameters_zh":[{"name":"范围","range":"(5 - 40) %"}],"search_zh":"重量法 范围 PB-PAZ/FS-21 wersja 01 z dnia 22.02.2021 r.","technique_zh":"重量法"},{"_id":"6a8369ecaf14b9c0e7b1dce0","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Wyroby ciastkarskie, Wyroby garmażeryjne","methodology":"Zawartość nadzienia","parameters":[{"name":"Zakres","range":"(10 - 60) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość nadzienia\nZakres (10 - 60) %\nMetoda wagowa","reference":"PB-PAZ/FS-21 wersja 01 z dnia 22.02.2021 r.","norm_bases":["PB-PAZ/FS-21 wersja 01 z dnia 22.02.2021 r."],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby ciastkarskie, Wyroby garmażeryjne Zawartość nadzienia\nZakres (10 - 60) %\nMetoda wagowa PB-PAZ/FS-21 wersja 01 z dnia 22.02.2021 r. Wyroby ciastkarskie, Wyroby garmazeryjne Zawartosc nadzienia\nZakres (10 - 60) %\nMetoda wagowa PB-PAZ/FS-21 wersja 01 z dnia 22.02.2021 r.","categories":["other"],"row_index":190,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Filling content","parameters_en":[{"name":"Range","range":"(10 - 60) %"}],"search_en":"Pastry products, Delicatessen products Filling content Gravimetric method Range PB-PAZ/FS-21 wersja 01 z dnia 22.02.2021 r.","technique_en":"Gravimetric method","test_object_en":"Pastry products, Delicatessen products","parameters_zh":[{"name":"范围","range":"(10 - 60) %"}],"search_zh":"重量法 范围 PB-PAZ/FS-21 wersja 01 z dnia 22.02.2021 r.","technique_zh":"重量法"},{"_id":"6a8369ecaf14b9c0e7b1dce1","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Pasze","methodology":"Zawartość cukrów ogółem","parameters":[{"name":"Zakres","range":"(0,5 - 40) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość cukrów ogółem\nZakres (0,5 - 40) %\nMetoda miareczkowa","reference":"Rozporządzenie Komisji (WE) nr 152/2009 z dn. 27.01.2009 r. (Dz. U. UE L 54/1 z 26.02.2009)","norm_bases":["Rozporządzenie Komisji (WE) nr 152/2009 z dn. 27.01.2009 r. (Dz. U. UE L 54/1 z 26.02.2009)"],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pasze Zawartość cukrów ogółem\nZakres (0,5 - 40) %\nMetoda miareczkowa Rozporządzenie Komisji (WE) nr 152/2009 z dn. 27.01.2009 r. (Dz. U. UE L 54/1 z 26.02.2009) Pasze Zawartosc cukrow ogolem\nZakres (0,5 - 40) %\nMetoda miareczkowa Rozporzadzenie Komisji (WE) nr 152/2009 z dn. 27.01.2009 r. (Dz. U. UE L 54/1 z 26.02.2009)","categories":["food"],"row_index":191,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total sugar content","parameters_en":[{"name":"Range","range":"(0,5 - 40) %"}],"search_en":"Feed Total sugar content Titrimetric method Range Rozporządzenie Komisji (WE) nr 152/2009 z dn. 27.01.2009 r. (Dz. U. UE L 54/1 z 26.02.2009)","technique_en":"Titrimetric method","test_object_en":"Feed","parameters_zh":[{"name":"范围","range":"(0,5 - 40) %"}],"search_zh":"饲料 总糖含量 滴定法 范围 Rozporządzenie Komisji (WE) nr 152/2009 z dn. 27.01.2009 r. (Dz. U. UE L 54/1 z 26.02.2009)","technique_zh":"滴定法","test_object_zh":"饲料","methodology_zh":"总糖含量"},{"_id":"6a8369ecaf14b9c0e7b1dce2","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Mięso i produkty mięsne, Ryby i przetwory rybne i owoce morza, Słodycze, wyroby cukiernicze, Wyroby ciastkarskie, mleko i produkty mleczne, Owoce i warzywa, przetwory owocowe, warzywne, owocowo-warzywne, Wyroby garmażeryjne, Koncentraty spożywcze, Zboża i przetwory zbożowe, Nasiona oleiste, Zioła i przyprawy, Oleje, tłuszcze zwierzęce i roślinne (z dodatkami), Herbata, Nasiona roślin strączkowych, Jaja i ich produkty, Napoje bezalkoholowe, napoje alkoholowe, Majonez, musztarda, sosy i dresingi, Pieczywo, półprodukty i wyroby piekarnicze, Bakalie i orzechy, Produkty ziemniaczane i zbożowe, Suplementy diety (z wyłączeniem płynnych na bazie olejów), produkty roślinne przetworzone","methodology":"Zawartość cukrów","parameters":[{"name":"glukoza","range":"(0,1 - 90,0) %"},{"name":"fruktoza","range":"(0,1 - 90,0) %"},{"name":"maltoza","range":"(0,1 - 90,0) %"},{"name":"laktoza","range":"(0,1 - 90,0) %"},{"name":"sacharoza","range":"(0,1 - 90,0) %"},{"name":"Suma cukrów (z obliczeń)"}],"technique":"Metoda chromatografii cieczowej z detekcją refraktometryczną (HPLC-RID)","techniques":["Metoda chromatografii cieczowej z detekcją refraktometryczną (HPLC-RID)"],"computed":[],"activity":"Zawartość cukrów\nZakres:\nglukoza (0,1 - 90,0) %\nfruktoza (0,1 - 90,0) %\nmaltoza (0,1 - 90,0) %\nlaktoza (0,1 - 90,0) %\nsacharoza (0,1 - 90,0) %\nSuma cukrów (z obliczeń)\nMetoda chromatografii cieczowej z detekcją refraktometryczną (HPLC-RID)","reference":"PB-PAZ/FS-43 wersja 02 z dnia 26.09.2025 r.","norm_bases":["PB-PAZ/FS-43 wersja 02 z dnia 26.09.2025 r."],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i produkty mięsne, Ryby i przetwory rybne i owoce morza, Słodycze, wyroby cukiernicze, Wyroby ciastkarskie, mleko i produkty mleczne, Owoce i warzywa, przetwory owocowe, warzywne, owocowo-warzywne, Wyroby garmażeryjne, Koncentraty spożywcze, Zboża i przetwory zbożowe, Nasiona oleiste, Zioła i przyprawy, Oleje, tłuszcze zwierzęce i roślinne (z dodatkami), Herbata, Nasiona roślin strączkowych, Jaja i ich produkty, Napoje bezalkoholowe, napoje alkoholowe, Majonez, musztarda, sosy i dresingi, Pieczywo, półprodukty i wyroby piekarnicze, Bakalie i orzechy, Produkty ziemniaczane i zbożowe, Suplementy diety (z wyłączeniem płynnych na bazie olejów), produkty roślinne przetworzone Zawartość cukrów\nZakres:\nglukoza (0,1 - 90,0) %\nfruktoza (0,1 - 90,0) %\nmaltoza (0,1 - 90,0) %\nlaktoza (0,1 - 90,0) %\nsacharoza (0,1 - 90,0) %\nSuma cukrów (z obliczeń)\nMetoda chromatografii cieczowej z detekcją refraktometryczną (HPLC-RID) PB-PAZ/FS-43 wersja 02 z dnia 26.09.2025 r. Mieso i produkty miesne, Ryby i przetwory rybne i owoce morza, Slodycze, wyroby cukiernicze, Wyroby ciastkarskie, mleko i produkty mleczne, Owoce i warzywa, przetwory owocowe, warzywne, owocowo-warzywne, Wyroby garmazeryjne, Koncentraty spozywcze, Zboza i przetwory zbozowe, Nasiona oleiste, Ziola i przyprawy, Oleje, tluszcze zwierzece i roslinne (z dodatkami), Herbata, Nasiona roslin straczkowych, Jaja i ich produkty, Napoje bezalkoholowe, napoje alkoholowe, Majonez, musztarda, sosy i dresingi, Pieczywo, polprodukty i wyroby piekarnicze, Bakalie i orzechy, Produkty ziemniaczane i zbozowe, Suplementy diety (z wylaczeniem plynnych na bazie olejow), produkty roslinne przetworzone Zawartosc cukrow\nZakres:\nglukoza (0,1 - 90,0) %\nfruktoza (0,1 - 90,0) %\nmaltoza (0,1 - 90,0) %\nlaktoza (0,1 - 90,0) %\nsacharoza (0,1 - 90,0) %\nSuma cukrow (z obliczen)\nMetoda chromatografii cieczowej z detekcja refraktometryczna (HPLC-RID) PB-PAZ/FS-43 wersja 02 z dnia 26.09.2025 r.","categories":["food","petro","pharma"],"row_index":192,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sugar content","parameters_en":[{"name":"glucose","range":"(0,1 - 90,0) %"},{"name":"fructose","range":"(0,1 - 90,0) %"},{"name":"maltose","range":"(0,1 - 90,0) %"},{"name":"lactose","range":"(0,1 - 90,0) %"},{"name":"sucrose","range":"(0,1 - 90,0) %"},{"name":"Sum of sugars (calculated)"}],"search_en":"Sugar content Liquid chromatography with refractive index detection (HPLC-RID) glucose fructose maltose lactose sucrose Sum of sugars (calculated) PB-PAZ/FS-43 wersja 02 z dnia 26.09.2025 r.","technique_en":"Liquid chromatography with refractive index detection (HPLC-RID)","methodology_zh":"糖含量","search_zh":"糖含量 液相色谱-示差折光检测法（HPLC-RID） 葡萄糖 果糖 蔗糖 PB-PAZ/FS-43 wersja 02 z dnia 26.09.2025 r.","parameters_zh":[{"name":"葡萄糖","range":"(0,1 - 90,0) %"},{"name":"果糖","range":"(0,1 - 90,0) %"},{"name":"maltoza","range":"(0,1 - 90,0) %"},{"name":"laktoza","range":"(0,1 - 90,0) %"},{"name":"蔗糖","range":"(0,1 - 90,0) %"},{"name":"Suma cukrów (z obliczeń)"}],"technique_zh":"液相色谱-示差折光检测法（HPLC-RID）"},{"_id":"6a8369ecaf14b9c0e7b1dce3","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Pasze","methodology":"Zawartość cukrów","parameters":[{"name":"glukoza","range":"(0,1 - 50,0) %"},{"name":"fruktoza","range":"(0,1 - 50,0) %"},{"name":"maltoza","range":"(0,1 - 50,0) %"},{"name":"laktoza","range":"(0,1 - 50,0) %"},{"name":"sacharoza","range":"(0,1 - 50,0) %"},{"name":"Suma cukrów (z obliczeń)"}],"technique":"Metoda chromatografii cieczowej z detekcją refraktometryczną (HPLC-RID)","techniques":["Metoda chromatografii cieczowej z detekcją refraktometryczną (HPLC-RID)"],"computed":[],"activity":"Zawartość cukrów\nZakres:\nglukoza (0,1 - 50,0) %\nfruktoza (0,1 - 50,0) %\nmaltoza (0,1 - 50,0) %\nlaktoza (0,1 - 50,0) %\nsacharoza (0,1 - 50,0) %\nSuma cukrów (z obliczeń)\nMetoda chromatografii cieczowej z detekcją refraktometryczną (HPLC-RID)","reference":"PB-PAZ/FS-43 wersja 02 z dnia 26.09.2025 r.","norm_bases":["PB-PAZ/FS-43 wersja 02 z dnia 26.09.2025 r."],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pasze Zawartość cukrów\nZakres:\nglukoza (0,1 - 50,0) %\nfruktoza (0,1 - 50,0) %\nmaltoza (0,1 - 50,0) %\nlaktoza (0,1 - 50,0) %\nsacharoza (0,1 - 50,0) %\nSuma cukrów (z obliczeń)\nMetoda chromatografii cieczowej z detekcją refraktometryczną (HPLC-RID) PB-PAZ/FS-43 wersja 02 z dnia 26.09.2025 r. Pasze Zawartosc cukrow\nZakres:\nglukoza (0,1 - 50,0) %\nfruktoza (0,1 - 50,0) %\nmaltoza (0,1 - 50,0) %\nlaktoza (0,1 - 50,0) %\nsacharoza (0,1 - 50,0) %\nSuma cukrow (z obliczen)\nMetoda chromatografii cieczowej z detekcja refraktometryczna (HPLC-RID) PB-PAZ/FS-43 wersja 02 z dnia 26.09.2025 r.","categories":["food"],"row_index":193,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sugar content","parameters_en":[{"name":"glucose","range":"(0,1 - 50,0) %"},{"name":"fructose","range":"(0,1 - 50,0) %"},{"name":"maltose","range":"(0,1 - 50,0) %"},{"name":"lactose","range":"(0,1 - 50,0) %"},{"name":"sucrose","range":"(0,1 - 50,0) %"},{"name":"Sum of sugars (calculated)"}],"search_en":"Feed Sugar content Liquid chromatography with refractive index detection (HPLC-RID) glucose fructose maltose lactose sucrose Sum of sugars (calculated) PB-PAZ/FS-43 wersja 02 z dnia 26.09.2025 r.","technique_en":"Liquid chromatography with refractive index detection (HPLC-RID)","test_object_en":"Feed","search_zh":"饲料 糖含量 液相色谱-示差折光检测法（HPLC-RID） 葡萄糖 果糖 蔗糖 PB-PAZ/FS-43 wersja 02 z dnia 26.09.2025 r.","test_object_zh":"饲料","methodology_zh":"糖含量","parameters_zh":[{"name":"葡萄糖","range":"(0,1 - 50,0) %"},{"name":"果糖","range":"(0,1 - 50,0) %"},{"name":"maltoza","range":"(0,1 - 50,0) %"},{"name":"laktoza","range":"(0,1 - 50,0) %"},{"name":"蔗糖","range":"(0,1 - 50,0) %"},{"name":"Suma cukrów (z obliczeń)"}],"technique_zh":"液相色谱-示差折光检测法（HPLC-RID）"},{"_id":"6a8369ecaf14b9c0e7b1dce4","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Przetwory owocowe, warzywne, owocowo-warzywne, mleko i produkty mleczne, koncentraty spożywcze, syropy, zaprawy, oleje, tłuszcze roślinne, napoje alkoholowe i bezalkoholowe, suplementy diety, sosy, majonezy, dresingi, żywność specjalnego przeznaczenia żywieniowego, miód, Płynne i półpłynne produkty do mycia, prania, czyszczenia, artykuły biurowe: korektor","methodology":"Objętość","parameters":[{"name":"Zakres","range":"(10 - 2000) ml"}],"technique":"Metoda objętościowa","techniques":["Metoda objętościowa"],"computed":[],"activity":"Objętość\nZakres (10 - 2000) ml\nMetoda objętościowa","reference":"PB-PAZ/FS-21 wersja 01 z dnia 22.02.2021 r.","norm_bases":["PB-PAZ/FS-21 wersja 01 z dnia 22.02.2021 r."],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Przetwory owocowe, warzywne, owocowo-warzywne, mleko i produkty mleczne, koncentraty spożywcze, syropy, zaprawy, oleje, tłuszcze roślinne, napoje alkoholowe i bezalkoholowe, suplementy diety, sosy, majonezy, dresingi, żywność specjalnego przeznaczenia żywieniowego, miód, Płynne i półpłynne produkty do mycia, prania, czyszczenia, artykuły biurowe: korektor Objętość\nZakres (10 - 2000) ml\nMetoda objętościowa PB-PAZ/FS-21 wersja 01 z dnia 22.02.2021 r. Woda do spozycia przez ludzi, Przetwory owocowe, warzywne, owocowo-warzywne, mleko i produkty mleczne, koncentraty spozywcze, syropy, zaprawy, oleje, tluszcze roslinne, napoje alkoholowe i bezalkoholowe, suplementy diety, sosy, majonezy, dresingi, zywnosc specjalnego przeznaczenia zywieniowego, miod, Plynne i polplynne produkty do mycia, prania, czyszczenia, artykuly biurowe: korektor Objetosc\nZakres (10 - 2000) ml\nMetoda objetosciowa PB-PAZ/FS-21 wersja 01 z dnia 22.02.2021 r.","categories":["food","water","petro","pharma"],"row_index":194,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Volume","parameters_en":[{"name":"Range","range":"(10 - 2000) ml"}],"search_en":"Water intended for human consumption, Fruit, vegetable and fruit-vegetable preserves, milk and milk products, food concentrates, syrups, fruit cordials, oils, vegetable fats, alcoholic and non-alcoholic beverages, dietary supplements, sauces, mayonnaises, dressings, foodstuffs for particular nutritional uses, honey, Liquid and semi-liquid products for washing, laundering and cleaning, office supplies: correction fluid Volume Volumetric method Range PB-PAZ/FS-21 wersja 01 z dnia 22.02.2021 r.","technique_en":"Volumetric method","test_object_en":"Water intended for human consumption, Fruit, vegetable and fruit-vegetable preserves, milk and milk products, food concentrates, syrups, fruit cordials, oils, vegetable fats, alcoholic and non-alcoholic beverages, dietary supplements, sauces, mayonnaises, dressings, foodstuffs for particular nutritional uses, honey, Liquid and semi-liquid products for washing, laundering and cleaning, office supplies: correction fluid","parameters_zh":[{"name":"范围","range":"(10 - 2000) ml"}],"search_zh":"体积 容量法 范围 PB-PAZ/FS-21 wersja 01 z dnia 22.02.2021 r.","technique_zh":"容量法","methodology_zh":"体积"},{"_id":"6a8369ecaf14b9c0e7b1dce5","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Oleje oraz tłuszcze roślinne i zwierzęce, mięso i przetwory mięsne, ryby, przetwory rybne i owoce morza, wyroby garmażeryjne, koncentraty spożywcze, zboża i produkty zbożowe, słodycze, wyroby cukiernicze i ciastkarskie, pieczywo, wyroby piekarnicze, napoje, owoce i warzywa, przetwory warzywno-owocowe, jaja i produkty jajeczne, mleko i przetwory mleczne, nasiona oleiste, bakalie i orzechy, nasiona roślin strączkowych, majonez, musztarda, sosy, dresingi, herbata, produkty ziemniaczane, suplementy diety, przyprawy, zioła, napoje alkoholowe, grzyby i produkty grzybowe, Pasze","methodology":"Udział % kwasów tłuszczowych:","parameters":[{"name":"(C17:0) kwas heptadekanowy (margarynowy)"},{"name":"(C17:1) kwas cis-10-heptadekenowy"},{"name":"(C18:0) kwas oktadekanowy (stearynowy)"},{"name":"(C18:1w9t) kwas oktadecenowy trans (elaidynowy)"},{"name":"(C18:1w9c) kwas oktadecenowy cis (oleinowy)"},{"name":"(C18:1w7) kwas cis-11 wakcenowy"},{"name":"(C18:2w6t) kwas linolelaidynowy trans (linoeladynowy)"},{"name":"(C18:2 trans – ct) kwas cis-9, trans-12 oktadekadienowy"},{"name":"(C18:2 trans – tc) kwas trans-9, cis-12 oktadekadienowy"},{"name":"(C18:2w6) kwas linolowy cis (LA)"},{"name":"(C20:0) kwas eikozanowy (arachidowy)"},{"name":"(C18:3w6) kwas gamma-linolenowy (GLA)"},{"name":"(C20:1w9) kwas cis-11-eikozenowy"},{"name":"(C18:3w3) kwas alfa-linolenowy (ALA)"},{"name":"(C21:0) kwas heneikozanowy"},{"name":"(C20:2) kwas cis-11,14-eikozadienowy"},{"name":"(C22:0) kwas dokozanowy (behenowy)"},{"name":"(C20:3w6) kwas cis-8,11,14-eikozatrienowy (DGLA)"},{"name":"(C22:1w9) kwas dokozenowy (erukowy)"},{"name":"(C20:3w3) kwas cis-11,14,17-eikozatrienowy (ETE)"},{"name":"(C23:0) kwas trikozanowy"},{"name":"(C20:4w6) kwas eikozatetraenowy (arachidonowy) (ARA)"},{"name":"(C22:2) kwas cis-13,16-dokosadienowy"},{"name":"(C24:0) kwas tetrakozanowy (lignocerynowy)"},{"name":"Zakres","range":"(0,05 - 95) %"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Udział % kwasów tłuszczowych:\nZakres:\n(C17:0) kwas heptadekanowy (margarynowy)\n(C17:1) kwas cis-10-heptadekenowy\n(C18:0) kwas oktadekanowy (stearynowy)\n(C18:1w9t) kwas oktadecenowy trans (elaidynowy)\n(C18:1w9c) kwas oktadecenowy cis (oleinowy)\n(C18:1w7) kwas cis-11 wakcenowy\n(C18:2w6t) kwas linolelaidynowy trans (linoeladynowy)\n(C18:2 trans – ct) kwas cis-9, trans-12 oktadekadienowy\n(C18:2 trans – tc) kwas trans-9, cis-12 oktadekadienowy\n(C18:2w6) kwas linolowy cis (LA)\n(C20:0) kwas eikozanowy (arachidowy)\n(C18:3w6) kwas gamma-linolenowy (GLA)\n(C20:1w9) kwas cis-11-eikozenowy\n(C18:3w3) kwas alfa-linolenowy (ALA)\n(C21:0) kwas heneikozanowy\n(C20:2) kwas cis-11,14-eikozadienowy\n(C22:0) kwas dokozanowy (behenowy)\n(C20:3w6) kwas cis-8,11,14-eikozatrienowy (DGLA)\n(C22:1w9) kwas dokozenowy (erukowy)\n(C20:3w3) kwas cis-11,14,17-eikozatrienowy (ETE)\n(C23:0) kwas trikozanowy\n(C20:4w6) kwas eikozatetraenowy (arachidonowy) (ARA)\n(C22:2) kwas cis-13,16-dokosadienowy\n(C24:0) kwas tetrakozanowy (lignocerynowy)\nZakres (0,05 - 95) %\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PB-PAZ/FS-34 wersja 04 z dnia 12.01.2024 r. z wyłączeniem pkt. 3.2","norm_bases":["PB-PAZ/FS-34 wersja 04 z dnia 12.01.2024 r. z wyłączeniem pkt. 3.2"],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Oleje oraz tłuszcze roślinne i zwierzęce, mięso i przetwory mięsne, ryby, przetwory rybne i owoce morza, wyroby garmażeryjne, koncentraty spożywcze, zboża i produkty zbożowe, słodycze, wyroby cukiernicze i ciastkarskie, pieczywo, wyroby piekarnicze, napoje, owoce i warzywa, przetwory warzywno-owocowe, jaja i produkty jajeczne, mleko i przetwory mleczne, nasiona oleiste, bakalie i orzechy, nasiona roślin strączkowych, majonez, musztarda, sosy, dresingi, herbata, produkty ziemniaczane, suplementy diety, przyprawy, zioła, napoje alkoholowe, grzyby i produkty grzybowe, Pasze Udział % kwasów tłuszczowych:\nZakres:\n(C17:0) kwas heptadekanowy (margarynowy)\n(C17:1) kwas cis-10-heptadekenowy\n(C18:0) kwas oktadekanowy (stearynowy)\n(C18:1w9t) kwas oktadecenowy trans (elaidynowy)\n(C18:1w9c) kwas oktadecenowy cis (oleinowy)\n(C18:1w7) kwas cis-11 wakcenowy\n(C18:2w6t) kwas linolelaidynowy trans (linoeladynowy)\n(C18:2 trans – ct) kwas cis-9, trans-12 oktadekadienowy\n(C18:2 trans – tc) kwas trans-9, cis-12 oktadekadienowy\n(C18:2w6) kwas linolowy cis (LA)\n(C20:0) kwas eikozanowy (arachidowy)\n(C18:3w6) kwas gamma-linolenowy (GLA)\n(C20:1w9) kwas cis-11-eikozenowy\n(C18:3w3) kwas alfa-linolenowy (ALA)\n(C21:0) kwas heneikozanowy\n(C20:2) kwas cis-11,14-eikozadienowy\n(C22:0) kwas dokozanowy (behenowy)\n(C20:3w6) kwas cis-8,11,14-eikozatrienowy (DGLA)\n(C22:1w9) kwas dokozenowy (erukowy)\n(C20:3w3) kwas cis-11,14,17-eikozatrienowy (ETE)\n(C23:0) kwas trikozanowy\n(C20:4w6) kwas eikozatetraenowy (arachidonowy) (ARA)\n(C22:2) kwas cis-13,16-dokosadienowy\n(C24:0) kwas tetrakozanowy (lignocerynowy)\nZakres (0,05 - 95) %\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PB-PAZ/FS-34 wersja 04 z dnia 12.01.2024 r. z wyłączeniem pkt. 3.2 Oleje oraz tluszcze roslinne i zwierzece, mieso i przetwory miesne, ryby, przetwory rybne i owoce morza, wyroby garmazeryjne, koncentraty spozywcze, zboza i produkty zbozowe, slodycze, wyroby cukiernicze i ciastkarskie, pieczywo, wyroby piekarnicze, napoje, owoce i warzywa, przetwory warzywno-owocowe, jaja i produkty jajeczne, mleko i przetwory mleczne, nasiona oleiste, bakalie i orzechy, nasiona roslin straczkowych, majonez, musztarda, sosy, dresingi, herbata, produkty ziemniaczane, suplementy diety, przyprawy, ziola, napoje alkoholowe, grzyby i produkty grzybowe, Pasze Udzial % kwasow tluszczowych:\nZakres:\n(C17:0) kwas heptadekanowy (margarynowy)\n(C17:1) kwas cis-10-heptadekenowy\n(C18:0) kwas oktadekanowy (stearynowy)\n(C18:1w9t) kwas oktadecenowy trans (elaidynowy)\n(C18:1w9c) kwas oktadecenowy cis (oleinowy)\n(C18:1w7) kwas cis-11 wakcenowy\n(C18:2w6t) kwas linolelaidynowy trans (linoeladynowy)\n(C18:2 trans – ct) kwas cis-9, trans-12 oktadekadienowy\n(C18:2 trans – tc) kwas trans-9, cis-12 oktadekadienowy\n(C18:2w6) kwas linolowy cis (LA)\n(C20:0) kwas eikozanowy (arachidowy)\n(C18:3w6) kwas gamma-linolenowy (GLA)\n(C20:1w9) kwas cis-11-eikozenowy\n(C18:3w3) kwas alfa-linolenowy (ALA)\n(C21:0) kwas heneikozanowy\n(C20:2) kwas cis-11,14-eikozadienowy\n(C22:0) kwas dokozanowy (behenowy)\n(C20:3w6) kwas cis-8,11,14-eikozatrienowy (DGLA)\n(C22:1w9) kwas dokozenowy (erukowy)\n(C20:3w3) kwas cis-11,14,17-eikozatrienowy (ETE)\n(C23:0) kwas trikozanowy\n(C20:4w6) kwas eikozatetraenowy (arachidonowy) (ARA)\n(C22:2) kwas cis-13,16-dokosadienowy\n(C24:0) kwas tetrakozanowy (lignocerynowy)\nZakres (0,05 - 95) %\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PB-PAZ/FS-34 wersja 04 z dnia 12.01.2024 r. z wylaczeniem pkt. 3.2","categories":["food","petro","microbiology","pharma"],"row_index":195,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"% share of fatty acids:","parameters_en":[{"name":"(C17:0) heptadecanoic (margaric) acid"},{"name":"(C17:1) cis-10-heptadecenoic acid"},{"name":"(C18:0) octadecanoic (stearic) acid"},{"name":"(C18:1w9t) trans octadecenoic (elaidic) acid"},{"name":"(C18:1w9c) cis octadecenoic (oleic) acid"},{"name":"(C18:1w7) cis-11 vaccenic acid"},{"name":"(C18:2w6t) trans linolelaidic acid (linolelaidic)"},{"name":"(C18:2 trans – ct) cis-9, trans-12 octadecadienoic acid"},{"name":"(C18:2 trans – tc) trans-9, cis-12 octadecadienoic acid"},{"name":"(C18:2w6) cis linoleic acid (LA)"},{"name":"(C20:0) eicosanoic (arachidic) acid"},{"name":"(C18:3w6) gamma-linolenic acid (GLA)"},{"name":"(C20:1w9) cis-11-eicosenoic acid"},{"name":"(C18:3w3) alpha-linolenic acid (ALA)"},{"name":"(C21:0) heneicosanoic acid"},{"name":"(C20:2) cis-11,14-eicosadienoic acid"},{"name":"(C22:0) docosanoic (behenic) acid"},{"name":"(C20:3w6) cis-8,11,14-eicosatrienoic acid (DGLA)"},{"name":"(C22:1w9) docosenoic (erucic) acid"},{"name":"(C20:3w3) cis-11,14,17-eicosatrienoic acid (ETE)"},{"name":"(C23:0) tricosanoic acid"},{"name":"(C20:4w6) eicosatetraenoic (arachidonic) acid (ARA)"},{"name":"(C22:2) cis-13,16-docosadienoic acid"},{"name":"(C24:0) tetracosanoic (lignoceric) acid"},{"name":"Range","range":"(0,05 - 95) %"}],"search_en":"Vegetable and animal oils and fats, meat and meat products, fish, fish products and seafood, delicatessen products, food concentrates, cereals and cereal products, sweets, confectionery and pastry products, bread, bakery products, beverages, fruit and vegetables, fruit-vegetable products, eggs and egg products, milk and milk products, oilseeds, dried fruit and nuts, legume seeds, mayonnaise, mustard, sauces, dressings, tea, potato products, food supplements, spices, herbs, alcoholic beverages, mushrooms and mushroom products, Feed % share of fatty acids: Gas chromatography with flame ionization detection (GC-FID) (C17:0) heptadecanoic (margaric) acid (C17:1) cis-10-heptadecenoic acid (C18:0) octadecanoic (stearic) acid (C18:1w9t) trans octadecenoic (elaidic) acid (C18:1w9c) cis octadecenoic (oleic) acid (C18:1w7) cis-11 vaccenic acid (C18:2w6t) trans linolelaidic acid (linolelaidic) (C18:2 trans – ct) cis-9, trans-12 octadecadienoic acid (C18:2 trans – tc) trans-9, cis-12 octadecadienoic acid (C18:2w6) cis linoleic acid (LA) (C20:0) eicosanoic (arachidic) acid (C18:3w6) gamma-linolenic acid (GLA) (C20:1w9) cis-11-eicosenoic acid (C18:3w3) alpha-linolenic acid (ALA) (C21:0) heneicosanoic acid (C20:2) cis-11,14-eicosadienoic acid (C22:0) docosanoic (behenic) acid (C20:3w6) cis-8,11,14-eicosatrienoic acid (DGLA) (C22:1w9) docosenoic (erucic) acid (C20:3w3) cis-11,14,17-eicosatrienoic acid (ETE) (C23:0) tricosanoic acid (C20:4w6) eicosatetraenoic (arachidonic) acid (ARA) (C22:2) cis-13,16-docosadienoic acid (C24:0) tetracosanoic (lignoceric) acid Range PB-PAZ/FS-34 wersja 04 z dnia 12.01.2024 r. z wyłączeniem pkt. 3.2","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Vegetable and animal oils and fats, meat and meat products, fish, fish products and seafood, delicatessen products, food concentrates, cereals and cereal products, sweets, confectionery and pastry products, bread, bakery products, beverages, fruit and vegetables, fruit-vegetable products, eggs and egg products, milk and milk products, oilseeds, dried fruit and nuts, legume seeds, mayonnaise, mustard, sauces, dressings, tea, potato products, food supplements, spices, herbs, alcoholic beverages, mushrooms and mushroom products, Feed","parameters_zh":[{"name":"(C17:0) kwas heptadekanowy (margarynowy)"},{"name":"(C17:1) kwas cis-10-heptadekenowy"},{"name":"(C18:0) kwas oktadekanowy (stearynowy)"},{"name":"(C18:1w9t) kwas oktadecenowy trans (elaidynowy)"},{"name":"(C18:1w9c) kwas oktadecenowy cis (oleinowy)"},{"name":"(C18:1w7) kwas cis-11 wakcenowy"},{"name":"(C18:2w6t) kwas linolelaidynowy trans (linoeladynowy)"},{"name":"(C18:2 trans – ct) kwas cis-9, trans-12 oktadekadienowy"},{"name":"(C18:2 trans – tc) kwas trans-9, cis-12 oktadekadienowy"},{"name":"(C18:2w6) kwas linolowy cis (LA)"},{"name":"(C20:0) kwas eikozanowy (arachidowy)"},{"name":"(C18:3w6) kwas gamma-linolenowy (GLA)"},{"name":"(C20:1w9) kwas cis-11-eikozenowy"},{"name":"(C18:3w3) kwas alfa-linolenowy (ALA)"},{"name":"(C21:0) kwas heneikozanowy"},{"name":"(C20:2) kwas cis-11,14-eikozadienowy"},{"name":"(C22:0) kwas dokozanowy (behenowy)"},{"name":"(C20:3w6) kwas cis-8,11,14-eikozatrienowy (DGLA)"},{"name":"(C22:1w9) kwas dokozenowy (erukowy)"},{"name":"(C20:3w3) kwas cis-11,14,17-eikozatrienowy (ETE)"},{"name":"(C23:0) kwas trikozanowy"},{"name":"(C20:4w6) kwas eikozatetraenowy (arachidonowy) (ARA)"},{"name":"(C22:2) kwas cis-13,16-dokosadienowy"},{"name":"(C24:0) kwas tetrakozanowy (lignocerynowy)"},{"name":"范围","range":"(0,05 - 95) %"}],"search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） 范围 PB-PAZ/FS-34 wersja 04 z dnia 12.01.2024 r. z wyłączeniem pkt. 3.2","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a8369ecaf14b9c0e7b1dce6","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Oleje oraz tłuszcze roślinne i zwierzęce, mięso i przetwory mięsne, ryby, przetwory rybne i owoce morza, wyroby garmażeryjne, koncentraty spożywcze, zboża i produkty zbożowe, słodycze, wyroby cukiernicze i ciastkarskie, pieczywo, wyroby piekarnicze, napoje, owoce i warzywa, przetwory warzywno-owocowe, jaja i produkty jajeczne, mleko i przetwory mleczne, nasiona oleiste, bakalie i orzechy, nasiona roślin strączkowych, majonez, musztarda, sosy, dresingi, herbata, produkty ziemniaczane, suplementy diety, przyprawy, zioła, napoje alkoholowe, grzyby i produkty grzybowe, Pasze","methodology":"Udział % kwasów tłuszczowych:","parameters":[{"name":"(C4:0) kwas butanowy (masłowy)"},{"name":"(C6:0) kwas heksanowy (kapronowy)"},{"name":"(C8:0) kwas oktanowy (kaprylowy)"},{"name":"(C10:0) kwas dekanowy (kaprynowy)"},{"name":"(C11:0) kwas undekanowy"},{"name":"(C12:0) kwas dodekanowy (laurynowy)"},{"name":"(C13:0) kwas tridekanowy (tridecylowy)"},{"name":"(C14:0) kwas tetradekanowy (mirystynowy)"},{"name":"(C14:1) kwas tetradekanowy (mirystyleinowy)"},{"name":"(C15:0) kwas pentadekanowy (pentadecylowy)"},{"name":"(C15:1) kwas cis-10-pentadekenowy"},{"name":"(C16:0) kwas heksadekanowy (palmitynowy)"},{"name":"(C16:1) kwas heksadecenowy (palmitoleinowy)"},{"name":"(C20:5w3) kwas cis-"},{"name":"5,8,11,14,17eikozapentaenowy (EPA)"},{"name":"(C24:1w9) kwas tetraeikozaenowy (nerwonowy)"},{"name":"(C22:5w3) kwas cis – 7,10,13,16,19 dokozapentaenowy (DPA)"},{"name":"(C22:6w3) kwas cis-4,7,10,13,16,19 dokozaheksaenowy (DHA)"},{"name":"Zakres","range":"(0,05 - 95) %"},{"name":"Suma kwasów tłuszczowych: nasyconych jednonienasyconych wielonienasyconych ( z o b li c z e ń ) S u m a k w a s ó w tłuszczowych trans"},{"name":"(C18","range":"1; C18:2)"},{"name":"(z obliczeń) Suma kwasów omega 3 i omega 6 (LA, GLA, ALA, EPA, ARA, DHA, DGLA, ETE, DPA) Suma kwasów omega 3: ALA, EPA, DHA, ETE, DPA Suma kwasów omega 6: LA, GLA, ARA, DGLA (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Udział % kwasów tłuszczowych:\nZakres:\n(C4:0) kwas butanowy (masłowy)\n(C6:0) kwas heksanowy (kapronowy)\n(C8:0) kwas oktanowy (kaprylowy)\n(C10:0) kwas dekanowy (kaprynowy)\n(C11:0) kwas undekanowy\n(C12:0) kwas dodekanowy (laurynowy)\n(C13:0) kwas tridekanowy (tridecylowy)\n(C14:0) kwas tetradekanowy (mirystynowy)\n(C14:1) kwas tetradekanowy (mirystyleinowy)\n(C15:0) kwas pentadekanowy (pentadecylowy)\n(C15:1) kwas cis-10-pentadekenowy\n(C16:0) kwas heksadekanowy (palmitynowy)\n(C16:1) kwas heksadecenowy (palmitoleinowy)\n(C20:5w3) kwas cis-\n5,8,11,14,17eikozapentaenowy (EPA)\n(C24:1w9) kwas tetraeikozaenowy (nerwonowy)\n(C22:5w3) kwas cis – 7,10,13,16,19 dokozapentaenowy (DPA)\n(C22:6w3) kwas cis-4,7,10,13,16,19 dokozaheksaenowy (DHA)\nZakres (0,05 - 95) %\nSuma kwasów tłuszczowych: nasyconych jednonienasyconych wielonienasyconych ( z o b li c z e ń ) S u m a k w a s ó w tłuszczowych trans\n(C18 1; C18:2)\n(z obliczeń) Suma kwasów omega 3 i omega 6 (LA, GLA, ALA, EPA, ARA, DHA, DGLA, ETE, DPA) Suma kwasów omega 3: ALA, EPA, DHA, ETE, DPA Suma kwasów omega 6: LA, GLA, ARA, DGLA (z obliczeń)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PB-PAZ/FS-34 wersja 04 z dnia 12.01.2024 r. z wyłączeniem pkt. 3.2","norm_bases":["PB-PAZ/FS-34 wersja 04 z dnia 12.01.2024 r. z wyłączeniem pkt. 3.2"],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Oleje oraz tłuszcze roślinne i zwierzęce, mięso i przetwory mięsne, ryby, przetwory rybne i owoce morza, wyroby garmażeryjne, koncentraty spożywcze, zboża i produkty zbożowe, słodycze, wyroby cukiernicze i ciastkarskie, pieczywo, wyroby piekarnicze, napoje, owoce i warzywa, przetwory warzywno-owocowe, jaja i produkty jajeczne, mleko i przetwory mleczne, nasiona oleiste, bakalie i orzechy, nasiona roślin strączkowych, majonez, musztarda, sosy, dresingi, herbata, produkty ziemniaczane, suplementy diety, przyprawy, zioła, napoje alkoholowe, grzyby i produkty grzybowe, Pasze Udział % kwasów tłuszczowych:\nZakres:\n(C4:0) kwas butanowy (masłowy)\n(C6:0) kwas heksanowy (kapronowy)\n(C8:0) kwas oktanowy (kaprylowy)\n(C10:0) kwas dekanowy (kaprynowy)\n(C11:0) kwas undekanowy\n(C12:0) kwas dodekanowy (laurynowy)\n(C13:0) kwas tridekanowy (tridecylowy)\n(C14:0) kwas tetradekanowy (mirystynowy)\n(C14:1) kwas tetradekanowy (mirystyleinowy)\n(C15:0) kwas pentadekanowy (pentadecylowy)\n(C15:1) kwas cis-10-pentadekenowy\n(C16:0) kwas heksadekanowy (palmitynowy)\n(C16:1) kwas heksadecenowy (palmitoleinowy)\n(C20:5w3) kwas cis-\n5,8,11,14,17eikozapentaenowy (EPA)\n(C24:1w9) kwas tetraeikozaenowy (nerwonowy)\n(C22:5w3) kwas cis – 7,10,13,16,19 dokozapentaenowy (DPA)\n(C22:6w3) kwas cis-4,7,10,13,16,19 dokozaheksaenowy (DHA)\nZakres (0,05 - 95) %\nSuma kwasów tłuszczowych: nasyconych jednonienasyconych wielonienasyconych ( z o b li c z e ń ) S u m a k w a s ó w tłuszczowych trans\n(C18 1; C18:2)\n(z obliczeń) Suma kwasów omega 3 i omega 6 (LA, GLA, ALA, EPA, ARA, DHA, DGLA, ETE, DPA) Suma kwasów omega 3: ALA, EPA, DHA, ETE, DPA Suma kwasów omega 6: LA, GLA, ARA, DGLA (z obliczeń)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PB-PAZ/FS-34 wersja 04 z dnia 12.01.2024 r. z wyłączeniem pkt. 3.2 Oleje oraz tluszcze roslinne i zwierzece, mieso i przetwory miesne, ryby, przetwory rybne i owoce morza, wyroby garmazeryjne, koncentraty spozywcze, zboza i produkty zbozowe, slodycze, wyroby cukiernicze i ciastkarskie, pieczywo, wyroby piekarnicze, napoje, owoce i warzywa, przetwory warzywno-owocowe, jaja i produkty jajeczne, mleko i przetwory mleczne, nasiona oleiste, bakalie i orzechy, nasiona roslin straczkowych, majonez, musztarda, sosy, dresingi, herbata, produkty ziemniaczane, suplementy diety, przyprawy, ziola, napoje alkoholowe, grzyby i produkty grzybowe, Pasze Udzial % kwasow tluszczowych:\nZakres:\n(C4:0) kwas butanowy (maslowy)\n(C6:0) kwas heksanowy (kapronowy)\n(C8:0) kwas oktanowy (kaprylowy)\n(C10:0) kwas dekanowy (kaprynowy)\n(C11:0) kwas undekanowy\n(C12:0) kwas dodekanowy (laurynowy)\n(C13:0) kwas tridekanowy (tridecylowy)\n(C14:0) kwas tetradekanowy (mirystynowy)\n(C14:1) kwas tetradekanowy (mirystyleinowy)\n(C15:0) kwas pentadekanowy (pentadecylowy)\n(C15:1) kwas cis-10-pentadekenowy\n(C16:0) kwas heksadekanowy (palmitynowy)\n(C16:1) kwas heksadecenowy (palmitoleinowy)\n(C20:5w3) kwas cis-\n5,8,11,14,17eikozapentaenowy (EPA)\n(C24:1w9) kwas tetraeikozaenowy (nerwonowy)\n(C22:5w3) kwas cis – 7,10,13,16,19 dokozapentaenowy (DPA)\n(C22:6w3) kwas cis-4,7,10,13,16,19 dokozaheksaenowy (DHA)\nZakres (0,05 - 95) %\nSuma kwasow tluszczowych: nasyconych jednonienasyconych wielonienasyconych ( z o b li c z e n ) S u m a k w a s o w tluszczowych trans\n(C18 1; C18:2)\n(z obliczen) Suma kwasow omega 3 i omega 6 (LA, GLA, ALA, EPA, ARA, DHA, DGLA, ETE, DPA) Suma kwasow omega 3: ALA, EPA, DHA, ETE, DPA Suma kwasow omega 6: LA, GLA, ARA, DGLA (z obliczen)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PB-PAZ/FS-34 wersja 04 z dnia 12.01.2024 r. z wylaczeniem pkt. 3.2","categories":["food","petro","microbiology","pharma"],"row_index":196,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"% share of fatty acids:","parameters_en":[{"name":"(C4:0) butanoic (butyric) acid"},{"name":"(C6:0) hexanoic (caproic) acid"},{"name":"(C8:0) octanoic (caprylic) acid"},{"name":"(C10:0) decanoic (capric) acid"},{"name":"(C11:0) undecanoic acid"},{"name":"(C12:0) dodecanoic (lauric) acid"},{"name":"(C13:0) tridecanoic (tridecylic) acid"},{"name":"(C14:0) tetradecanoic (myristic) acid"},{"name":"(C14:1) tetradecanoic (myristoleic) acid"},{"name":"(C15:0) pentadecanoic (pentadecylic) acid"},{"name":"(C15:1) cis-10-pentadecenoic acid"},{"name":"(C16:0) hexadecanoic (palmitic) acid"},{"name":"(C16:1) hexadecenoic (palmitoleic) acid"},{"name":"(C20:5w3) cis-"},{"name":"5,8,11,14,17eicosapentaenoic (EPA)"},{"name":"(C24:1w9) tetracosenoic (nervonic) acid"},{"name":"(C22:5w3) cis – 7,10,13,16,19 docosapentaenoic acid (DPA)"},{"name":"(C22:6w3) cis-4,7,10,13,16,19 docosahexaenoic acid (DHA)"},{"name":"Range","range":"(0,05 - 95) %"},{"name":"Sum of fatty acids: saturated monounsaturated polyunsaturated (calculated) Sum of trans fatty acids"},{"name":"(C18","range":"1; C18:2)"},{"name":"(calculated) Sum of omega 3 and omega 6 acids (LA, GLA, ALA, EPA, ARA, DHA, DGLA, ETE, DPA) Sum of omega 3 acids: ALA, EPA, DHA, ETE, DPA Sum of omega 6 acids: LA, GLA, ARA, DGLA (calculated)"}],"search_en":"Vegetable and animal oils and fats, meat and meat products, fish, fish products and seafood, delicatessen products, food concentrates, cereals and cereal products, sweets, confectionery and pastry products, bread, bakery products, beverages, fruit and vegetables, fruit-vegetable products, eggs and egg products, milk and milk products, oilseeds, dried fruit and nuts, legume seeds, mayonnaise, mustard, sauces, dressings, tea, potato products, food supplements, spices, herbs, alcoholic beverages, mushrooms and mushroom products, Feed % share of fatty acids: Gas chromatography with flame ionization detection (GC-FID) (C4:0) butanoic (butyric) acid (C6:0) hexanoic (caproic) acid (C8:0) octanoic (caprylic) acid (C10:0) decanoic (capric) acid (C11:0) undecanoic acid (C12:0) dodecanoic (lauric) acid (C13:0) tridecanoic (tridecylic) acid (C14:0) tetradecanoic (myristic) acid (C14:1) tetradecanoic (myristoleic) acid (C15:0) pentadecanoic (pentadecylic) acid (C15:1) cis-10-pentadecenoic acid (C16:0) hexadecanoic (palmitic) acid (C16:1) hexadecenoic (palmitoleic) acid (C20:5w3) cis- 5,8,11,14,17eicosapentaenoic (EPA) (C24:1w9) tetracosenoic (nervonic) acid (C22:5w3) cis – 7,10,13,16,19 docosapentaenoic acid (DPA) (C22:6w3) cis-4,7,10,13,16,19 docosahexaenoic acid (DHA) Range Sum of fatty acids: saturated monounsaturated polyunsaturated (calculated) Sum of trans fatty acids (C18 (calculated) Sum of omega 3 and omega 6 acids (LA, GLA, ALA, EPA, ARA, DHA, DGLA, ETE, DPA) Sum of omega 3 acids: ALA, EPA, DHA, ETE, DPA Sum of omega 6 acids: LA, GLA, ARA, DGLA (calculated) PB-PAZ/FS-34 wersja 04 z dnia 12.01.2024 r. z wyłączeniem pkt. 3.2","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Vegetable and animal oils and fats, meat and meat products, fish, fish products and seafood, delicatessen products, food concentrates, cereals and cereal products, sweets, confectionery and pastry products, bread, bakery products, beverages, fruit and vegetables, fruit-vegetable products, eggs and egg products, milk and milk products, oilseeds, dried fruit and nuts, legume seeds, mayonnaise, mustard, sauces, dressings, tea, potato products, food supplements, spices, herbs, alcoholic beverages, mushrooms and mushroom products, Feed","parameters_zh":[{"name":"(C4:0) kwas butanowy (masłowy)"},{"name":"(C6:0) kwas heksanowy (kapronowy)"},{"name":"(C8:0) kwas oktanowy (kaprylowy)"},{"name":"(C10:0) kwas dekanowy (kaprynowy)"},{"name":"(C11:0) kwas undekanowy"},{"name":"(C12:0) kwas dodekanowy (laurynowy)"},{"name":"(C13:0) kwas tridekanowy (tridecylowy)"},{"name":"(C14:0) kwas tetradekanowy (mirystynowy)"},{"name":"(C14:1) kwas tetradekanowy (mirystyleinowy)"},{"name":"(C15:0) kwas pentadekanowy (pentadecylowy)"},{"name":"(C15:1) kwas cis-10-pentadekenowy"},{"name":"(C16:0) kwas heksadekanowy (palmitynowy)"},{"name":"(C16:1) kwas heksadecenowy (palmitoleinowy)"},{"name":"(C20:5w3) kwas cis-"},{"name":"5,8,11,14,17eikozapentaenowy (EPA)"},{"name":"(C24:1w9) kwas tetraeikozaenowy (nerwonowy)"},{"name":"(C22:5w3) kwas cis – 7,10,13,16,19 dokozapentaenowy (DPA)"},{"name":"(C22:6w3) kwas cis-4,7,10,13,16,19 dokozaheksaenowy (DHA)"},{"name":"范围","range":"(0,05 - 95) %"},{"name":"Suma kwasów tłuszczowych: nasyconych jednonienasyconych wielonienasyconych ( z o b li c z e ń ) S u m a k w a s ó w tłuszczowych trans"},{"name":"(C18","range":"1; C18:2)"},{"name":"(z obliczeń) Suma kwasów omega 3 i omega 6 (LA, GLA, ALA, EPA, ARA, DHA, DGLA, ETE, DPA) Suma kwasów omega 3: ALA, EPA, DHA, ETE, DPA Suma kwasów omega 6: LA, GLA, ARA, DGLA (z obliczeń)"}],"search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） 范围 PB-PAZ/FS-34 wersja 04 z dnia 12.01.2024 r. z wyłączeniem pkt. 3.2","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a8369ecaf14b9c0e7b1dce7","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Mięso i produkty mięsne, produkty zbożowe, przyprawy, słodycze i wyroby cukiernicze, mleko i produkty mleczne, owoce suszone i bakalie","methodology":"Aktywność wody","parameters":[{"name":"Zakres","range":"(0,250 - 0.999)"}],"technique":"Metoda pomiaru punktu rosy","techniques":["Metoda pomiaru punktu rosy"],"computed":[],"activity":"Aktywność wody\nZakres (0,250 - 0.999)\nMetoda pomiaru punktu rosy","reference":"PN-ISO 21807:2005","norm_bases":["PN-ISO 21807:2005"],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i produkty mięsne, produkty zbożowe, przyprawy, słodycze i wyroby cukiernicze, mleko i produkty mleczne, owoce suszone i bakalie Aktywność wody\nZakres (0,250 - 0.999)\nMetoda pomiaru punktu rosy PN-ISO 21807:2005 Mieso i produkty miesne, produkty zbozowe, przyprawy, slodycze i wyroby cukiernicze, mleko i produkty mleczne, owoce suszone i bakalie Aktywnosc wody\nZakres (0,250 - 0.999)\nMetoda pomiaru punktu rosy PN-ISO 21807:2005","categories":["food","water"],"row_index":197,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water activity","parameters_en":[{"name":"Range","range":"(0,250 - 0.999)"}],"search_en":"Meat and meat products, cereal products, spices, sweets and confectionery, milk and dairy products, dried fruit and nuts Water activity Dew point measurement method Range PN-ISO 21807:2005","technique_en":"Dew point measurement method","test_object_en":"Meat and meat products, cereal products, spices, sweets and confectionery, milk and dairy products, dried fruit and nuts","methodology_zh":"水分活度","parameters_zh":[{"name":"范围","range":"(0,250 - 0.999)"}],"search_zh":"水分活度 范围 PN-ISO 21807:2005"},{"_id":"6a8369ecaf14b9c0e7b1dce8","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Pasze, Wyroby chemii gospodarczej i kosmetyki","methodology":"pH","parameters":[{"name":"Zakres","range":"2,00 - 12,00"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,00 - 12,00\nMetoda potencjometryczna","reference":"PB-PAZ/FS-06 wersja 01 z dnia 22.02.2021 r.","norm_bases":["PB-PAZ/FS-06 wersja 01 z dnia 22.02.2021 r."],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pasze, Wyroby chemii gospodarczej i kosmetyki pH\nZakres 2,00 - 12,00\nMetoda potencjometryczna PB-PAZ/FS-06 wersja 01 z dnia 22.02.2021 r. Pasze, Wyroby chemii gospodarczej i kosmetyki pH\nZakres 2,00 - 12,00\nMetoda potencjometryczna PB-PAZ/FS-06 wersja 01 z dnia 22.02.2021 r.","categories":["food","pharma"],"row_index":198,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,00 - 12,00"}],"search_en":"Feed, Household chemical products and cosmetics pH Potentiometric method Range PB-PAZ/FS-06 wersja 01 z dnia 22.02.2021 r.","technique_en":"Potentiometric method","test_object_en":"Feed, Household chemical products and cosmetics","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,00 - 12,00"}],"search_zh":"pH 值 电位法 范围 PB-PAZ/FS-06 wersja 01 z dnia 22.02.2021 r.","technique_zh":"电位法"},{"_id":"6a8369ecaf14b9c0e7b1dce9","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Stałe produkty do mycia, prania, czyszczenia","methodology":"Masa netto Masa brutto","parameters":[{"name":"Zakres","range":"(1 - 2000) g"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Masa netto Masa brutto\nZakres (1 - 2000) g\nMetoda wagowa","reference":"PB-PAZ/FS-21 wersja 01 z dnia 22.02.2021 r.","norm_bases":["PB-PAZ/FS-21 wersja 01 z dnia 22.02.2021 r."],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Stałe produkty do mycia, prania, czyszczenia Masa netto Masa brutto\nZakres (1 - 2000) g\nMetoda wagowa PB-PAZ/FS-21 wersja 01 z dnia 22.02.2021 r. Stale produkty do mycia, prania, czyszczenia Masa netto Masa brutto\nZakres (1 - 2000) g\nMetoda wagowa PB-PAZ/FS-21 wersja 01 z dnia 22.02.2021 r.","categories":["other"],"row_index":199,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Net mass Gross mass","parameters_en":[{"name":"Range","range":"(1 - 2000) g"}],"search_en":"Solid washing, laundry and cleaning products Net mass Gross mass Gravimetric method Range PB-PAZ/FS-21 wersja 01 z dnia 22.02.2021 r.","technique_en":"Gravimetric method","test_object_en":"Solid washing, laundry and cleaning products","parameters_zh":[{"name":"范围","range":"(1 - 2000) g"}],"search_zh":"重量法 范围 PB-PAZ/FS-21 wersja 01 z dnia 22.02.2021 r.","technique_zh":"重量法"},{"_id":"6a8369ecaf14b9c0e7b1dcea","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Pasze","methodology":"Zawartość aflatoksyn B1, B2, G1, G2","parameters":[{"name":"aflatoksyna B1","range":"(2,5 - 50,0) μg/kg"},{"name":"aflatoksyna B2","range":"(2,5 - 50,0) μg/kg"},{"name":"aflatoksyna G1","range":"(2,5 - 50,0) μg/kg"},{"name":"aflatoksyna G2","range":"(2,5 - 50,0) μg/kg"},{"name":"Suma aflatoksyn (z obliczeń)"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Zawartość aflatoksyn B1, B2, G1, G2\nZakres:\naflatoksyna B1 (2,5 - 50,0) μg/kg\naflatoksyna B2 (2,5 - 50,0) μg/kg\naflatoksyna G1 (2,5 - 50,0) μg/kg\naflatoksyna G2 (2,5 - 50,0) μg/kg\nSuma aflatoksyn (z obliczeń)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"PB-PAZ/FS-01 wersja 03 z dnia 10.03.2022 r.","norm_bases":["PB-PAZ/FS-01 wersja 03 z dnia 10.03.2022 r."],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pasze Zawartość aflatoksyn B1, B2, G1, G2\nZakres:\naflatoksyna B1 (2,5 - 50,0) μg/kg\naflatoksyna B2 (2,5 - 50,0) μg/kg\naflatoksyna G1 (2,5 - 50,0) μg/kg\naflatoksyna G2 (2,5 - 50,0) μg/kg\nSuma aflatoksyn (z obliczeń)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) PB-PAZ/FS-01 wersja 03 z dnia 10.03.2022 r. Pasze Zawartosc aflatoksyn B1, B2, G1, G2\nZakres:\naflatoksyna B1 (2,5 - 50,0) μg/kg\naflatoksyna B2 (2,5 - 50,0) μg/kg\naflatoksyna G1 (2,5 - 50,0) μg/kg\naflatoksyna G2 (2,5 - 50,0) μg/kg\nSuma aflatoksyn (z obliczen)\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) PB-PAZ/FS-01 wersja 03 z dnia 10.03.2022 r.","categories":["food"],"row_index":200,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Aflatoxin B1, B2, G1, G2 content","parameters_en":[{"name":"aflatoxin B1","range":"(2,5 - 50,0) μg/kg"},{"name":"aflatoxin B2","range":"(2,5 - 50,0) μg/kg"},{"name":"aflatoxin G1","range":"(2,5 - 50,0) μg/kg"},{"name":"aflatoxin G2","range":"(2,5 - 50,0) μg/kg"},{"name":"Sum of aflatoxins (calculated)"}],"search_en":"Feed Aflatoxin B1, B2, G1, G2 content High-performance liquid chromatography with fluorescence detection (HPLC-FLD) aflatoxin B1 aflatoxin B2 aflatoxin G1 aflatoxin G2 Sum of aflatoxins (calculated) PB-PAZ/FS-01 wersja 03 z dnia 10.03.2022 r.","technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD)","test_object_en":"Feed","search_zh":"饲料 黄曲霉毒素 B1、B2、G1、G2 含量 高效液相色谱-荧光检测法（HPLC-FLD） PB-PAZ/FS-01 wersja 03 z dnia 10.03.2022 r.","technique_zh":"高效液相色谱-荧光检测法（HPLC-FLD）","test_object_zh":"饲料","methodology_zh":"黄曲霉毒素 B1、B2、G1、G2 含量"},{"_id":"6a8369ecaf14b9c0e7b1dceb","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Pasze","methodology":"Zawartość ochratoksyny A","parameters":[{"name":"Zakres","range":"(5,0 - 50,0) μg/kg"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Zawartość ochratoksyny A\nZakres (5,0 - 50,0) μg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"PB-PAZ/FS-02 wersja 02 z dnia 01.02.2021 r.","norm_bases":["PB-PAZ/FS-02 wersja 02 z dnia 01.02.2021 r."],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pasze Zawartość ochratoksyny A\nZakres (5,0 - 50,0) μg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) PB-PAZ/FS-02 wersja 02 z dnia 01.02.2021 r. Pasze Zawartosc ochratoksyny A\nZakres (5,0 - 50,0) μg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) PB-PAZ/FS-02 wersja 02 z dnia 01.02.2021 r.","categories":["food"],"row_index":201,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ochratoxin A content","parameters_en":[{"name":"Range","range":"(5,0 - 50,0) μg/kg"}],"search_en":"Feed Ochratoxin A content High-performance liquid chromatography with fluorescence detection (HPLC-FLD) Range PB-PAZ/FS-02 wersja 02 z dnia 01.02.2021 r.","technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD)","test_object_en":"Feed","parameters_zh":[{"name":"范围","range":"(5,0 - 50,0) μg/kg"}],"search_zh":"饲料 赭曲霉毒素 A 含量 高效液相色谱-荧光检测法（HPLC-FLD） 范围 PB-PAZ/FS-02 wersja 02 z dnia 01.02.2021 r.","technique_zh":"高效液相色谱-荧光检测法（HPLC-FLD）","test_object_zh":"饲料","methodology_zh":"赭曲霉毒素 A 含量"},{"_id":"6a8369ecaf14b9c0e7b1dcec","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Bakalie, orzechy, herbata, przetwory owocowe, warzywne, owocowo-warzywne, słodycze i wyroby cukiernicze, wyroby garmażeryjne, zboża i przetwory zbożowe, przyprawy i zioła, pieczywo i produkty piekarnicze","methodology":"Zawartość aflatoksyn B1, B2, G1, G2","parameters":[{"name":"aflatoksyna B1","range":"(0,4 - 10,0) μg/kg"},{"name":"aflatoksyna B2","range":"(0,4 - 10,0) μg/kg"},{"name":"aflatoksyna G1","range":"(0,4 - 10,0) μg/kg"},{"name":"aflatoksyna G2","range":"(0,4 - 10,0) μg/kg"},{"name":"Suma aflatoksyn (z obliczeń)"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Zawartość aflatoksyn B1, B2, G1, G2\nZakres:\naflatoksyna B1 (0,4 - 10,0) μg/kg\naflatoksyna B2 (0,4 - 10,0) μg/kg\naflatoksyna G1 (0,4 - 10,0) μg/kg\naflatoksyna G2 (0,4 - 10,0) μg/kg\nSuma aflatoksyn (z obliczeń)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"PB-PAZ/FS-01 wersja 03 z dnia 10.03.2022 r.","norm_bases":["PB-PAZ/FS-01 wersja 03 z dnia 10.03.2022 r."],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Bakalie, orzechy, herbata, przetwory owocowe, warzywne, owocowo-warzywne, słodycze i wyroby cukiernicze, wyroby garmażeryjne, zboża i przetwory zbożowe, przyprawy i zioła, pieczywo i produkty piekarnicze Zawartość aflatoksyn B1, B2, G1, G2\nZakres:\naflatoksyna B1 (0,4 - 10,0) μg/kg\naflatoksyna B2 (0,4 - 10,0) μg/kg\naflatoksyna G1 (0,4 - 10,0) μg/kg\naflatoksyna G2 (0,4 - 10,0) μg/kg\nSuma aflatoksyn (z obliczeń)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) PB-PAZ/FS-01 wersja 03 z dnia 10.03.2022 r. Bakalie, orzechy, herbata, przetwory owocowe, warzywne, owocowo-warzywne, slodycze i wyroby cukiernicze, wyroby garmazeryjne, zboza i przetwory zbozowe, przyprawy i ziola, pieczywo i produkty piekarnicze Zawartosc aflatoksyn B1, B2, G1, G2\nZakres:\naflatoksyna B1 (0,4 - 10,0) μg/kg\naflatoksyna B2 (0,4 - 10,0) μg/kg\naflatoksyna G1 (0,4 - 10,0) μg/kg\naflatoksyna G2 (0,4 - 10,0) μg/kg\nSuma aflatoksyn (z obliczen)\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) PB-PAZ/FS-01 wersja 03 z dnia 10.03.2022 r.","categories":["food"],"row_index":202,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Aflatoxin B1, B2, G1, G2 content","parameters_en":[{"name":"aflatoxin B1","range":"(0,4 - 10,0) μg/kg"},{"name":"aflatoxin B2","range":"(0,4 - 10,0) μg/kg"},{"name":"aflatoxin G1","range":"(0,4 - 10,0) μg/kg"},{"name":"aflatoxin G2","range":"(0,4 - 10,0) μg/kg"},{"name":"Sum of aflatoxins (calculated)"}],"search_en":"Dried fruits, nuts, tea, fruit, vegetable and fruit-vegetable preserves, sweets and confectionery, delicatessen products, cereals and cereal products, spices and herbs, bread and bakery products Aflatoxin B1, B2, G1, G2 content High-performance liquid chromatography with fluorescence detection (HPLC-FLD) aflatoxin B1 aflatoxin B2 aflatoxin G1 aflatoxin G2 Sum of aflatoxins (calculated) PB-PAZ/FS-01 wersja 03 z dnia 10.03.2022 r.","technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD)","test_object_en":"Dried fruits, nuts, tea, fruit, vegetable and fruit-vegetable preserves, sweets and confectionery, delicatessen products, cereals and cereal products, spices and herbs, bread and bakery products","search_zh":"黄曲霉毒素 B1、B2、G1、G2 含量 高效液相色谱-荧光检测法（HPLC-FLD） PB-PAZ/FS-01 wersja 03 z dnia 10.03.2022 r.","technique_zh":"高效液相色谱-荧光检测法（HPLC-FLD）","methodology_zh":"黄曲霉毒素 B1、B2、G1、G2 含量"},{"_id":"6a8369ecaf14b9c0e7b1dced","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Bakalie, orzechy, przetwory owocowe, warzywne, owocowo- warzywne, słodycze i wyroby cukiernicze, zboża i przetwory zbożowe, przyprawy i zioła, kawa, wino, piwo","methodology":"Zawartość ochratoksyny A","parameters":[{"name":"Zakres","range":"(0,5 - 20,0) μg/kg"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Zawartość ochratoksyny A\nZakres (0,5 - 20,0) μg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"PB-PAZ/FS-02 wersja 02 z dnia 01.02.2021 r","norm_bases":["PB-PAZ/FS-02 wersja 02 z dnia 01.02.2021 r"],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Bakalie, orzechy, przetwory owocowe, warzywne, owocowo- warzywne, słodycze i wyroby cukiernicze, zboża i przetwory zbożowe, przyprawy i zioła, kawa, wino, piwo Zawartość ochratoksyny A\nZakres (0,5 - 20,0) μg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) PB-PAZ/FS-02 wersja 02 z dnia 01.02.2021 r Bakalie, orzechy, przetwory owocowe, warzywne, owocowo- warzywne, slodycze i wyroby cukiernicze, zboza i przetwory zbozowe, przyprawy i ziola, kawa, wino, piwo Zawartosc ochratoksyny A\nZakres (0,5 - 20,0) μg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) PB-PAZ/FS-02 wersja 02 z dnia 01.02.2021 r","categories":["food"],"row_index":203,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ochratoxin A content","parameters_en":[{"name":"Range","range":"(0,5 - 20,0) μg/kg"}],"search_en":"Dried fruits, nuts, fruit, vegetable and fruit-vegetable preserves, sweets and confectionery, cereals and cereal products, spices and herbs, coffee, wine, beer Ochratoxin A content High-performance liquid chromatography with fluorescence detection (HPLC-FLD) Range PB-PAZ/FS-02 wersja 02 z dnia 01.02.2021 r","technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD)","test_object_en":"Dried fruits, nuts, fruit, vegetable and fruit-vegetable preserves, sweets and confectionery, cereals and cereal products, spices and herbs, coffee, wine, beer","parameters_zh":[{"name":"范围","range":"(0,5 - 20,0) μg/kg"}],"search_zh":"赭曲霉毒素 A 含量 高效液相色谱-荧光检测法（HPLC-FLD） 范围 PB-PAZ/FS-02 wersja 02 z dnia 01.02.2021 r","technique_zh":"高效液相色谱-荧光检测法（HPLC-FLD）","methodology_zh":"赭曲霉毒素 A 含量"},{"_id":"6a8369ecaf14b9c0e7b1dcee","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Przetwory owocowe i warzywne, Mleko i produkty mleczne, Mięso i produkty mięsne, Ryby i przetwory rybne, Słodycze i wyroby cukiernicze, Napoje bezalkoholowe, Przetwory zbożowe, Koncentraty spożywcze, Wyroby garmażeryjne","methodology":"Zawartość substancji konserwujących","parameters":[{"name":"kwas benzoesowy i jego sole"},{"name":"Zakres","range":"(1,0 – 8000) mg/kg lub mg/l"},{"name":"kwas sorbowy i jego sole (1,0 – 8000) mg/kg lub mg/l"}],"technique":"Metoda chromatografii cieczowej z detekcją diodową (HPLC-DAD)","techniques":["Metoda chromatografii cieczowej z detekcją diodową (HPLC-DAD)"],"computed":[],"activity":"Zawartość substancji konserwujących\nZakres:\nkwas benzoesowy i jego sole\nZakres (1,0 – 8000) mg/kg lub mg/l\nkwas sorbowy i jego sole (1,0 – 8000) mg/kg lub mg/l\nMetoda chromatografii cieczowej z detekcją diodową (HPLC-DAD)","reference":"PB-PAZ/FS-46 wersja 01 z dnia 16.01.2026","norm_bases":["PB-PAZ/FS-46 wersja 01 z dnia 16.01.2026"],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przetwory owocowe i warzywne, Mleko i produkty mleczne, Mięso i produkty mięsne, Ryby i przetwory rybne, Słodycze i wyroby cukiernicze, Napoje bezalkoholowe, Przetwory zbożowe, Koncentraty spożywcze, Wyroby garmażeryjne Zawartość substancji konserwujących\nZakres:\nkwas benzoesowy i jego sole\nZakres (1,0 – 8000) mg/kg lub mg/l\nkwas sorbowy i jego sole (1,0 – 8000) mg/kg lub mg/l\nMetoda chromatografii cieczowej z detekcją diodową (HPLC-DAD) PB-PAZ/FS-46 wersja 01 z dnia 16.01.2026 Przetwory owocowe i warzywne, Mleko i produkty mleczne, Mieso i produkty miesne, Ryby i przetwory rybne, Slodycze i wyroby cukiernicze, Napoje bezalkoholowe, Przetwory zbozowe, Koncentraty spozywcze, Wyroby garmazeryjne Zawartosc substancji konserwujacych\nZakres:\nkwas benzoesowy i jego sole\nZakres (1,0 – 8000) mg/kg lub mg/l\nkwas sorbowy i jego sole (1,0 – 8000) mg/kg lub mg/l\nMetoda chromatografii cieczowej z detekcja diodowa (HPLC-DAD) PB-PAZ/FS-46 wersja 01 z dnia 16.01.2026","categories":["food"],"row_index":204,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Preservative content","parameters_en":[{"name":"benzoic acid and its salts"},{"name":"Range","range":"(1,0 – 8000) mg/kg lub mg/l"},{"name":"kwas sorbowy i jego sole (1,0 – 8000) mg/kg lub mg/l"}],"search_en":"Preservative content Liquid chromatography with diode array detection (HPLC-DAD) benzoic acid and its salts Range PB-PAZ/FS-46 wersja 01 z dnia 16.01.2026","technique_en":"Liquid chromatography with diode array detection (HPLC-DAD)","parameters_zh":[{"name":"kwas benzoesowy i jego sole"},{"name":"范围","range":"(1,0 – 8000) mg/kg lub mg/l"},{"name":"kwas sorbowy i jego sole (1,0 – 8000) mg/kg lub mg/l"}],"search_zh":"防腐剂含量 范围 PB-PAZ/FS-46 wersja 01 z dnia 16.01.2026","methodology_zh":"防腐剂含量"},{"_id":"6a8369ecaf14b9c0e7b1dcef","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Przetwory owocowe i przetwory warzywne, Mleko i produkty mleczne, Słodycze i wyroby cukiernicze, Napoje bezalkoholowe, Przetwory zbożowe, Koncentraty spożywcze, Wyroby garmażeryjne, Suplementy diety","methodology":"Zawartość substancji słodzących","parameters":[{"name":"aspartam"},{"name":"Zakres","range":"(1,0 – 4000) mg/kg lub mg/l"},{"name":"acesulfam-K (1,0 – 4000) mg/kg lub mg/l sacharyna i jej sole (1,0 – 4000) mg/kg lub mg/l"}],"technique":"Metoda chromatografii cieczowej z detekcją diodową (HPLC-DAD)","techniques":["Metoda chromatografii cieczowej z detekcją diodową (HPLC-DAD)"],"computed":[],"activity":"Zawartość substancji słodzących\nZakres:\naspartam\nZakres (1,0 – 4000) mg/kg lub mg/l\nacesulfam-K (1,0 – 4000) mg/kg lub mg/l sacharyna i jej sole (1,0 – 4000) mg/kg lub mg/l\nMetoda chromatografii cieczowej z detekcją diodową (HPLC-DAD)","reference":"PB-PAZ/FS-46 wersja 01 z dnia 16.01.2026","norm_bases":["PB-PAZ/FS-46 wersja 01 z dnia 16.01.2026"],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przetwory owocowe i przetwory warzywne, Mleko i produkty mleczne, Słodycze i wyroby cukiernicze, Napoje bezalkoholowe, Przetwory zbożowe, Koncentraty spożywcze, Wyroby garmażeryjne, Suplementy diety Zawartość substancji słodzących\nZakres:\naspartam\nZakres (1,0 – 4000) mg/kg lub mg/l\nacesulfam-K (1,0 – 4000) mg/kg lub mg/l sacharyna i jej sole (1,0 – 4000) mg/kg lub mg/l\nMetoda chromatografii cieczowej z detekcją diodową (HPLC-DAD) PB-PAZ/FS-46 wersja 01 z dnia 16.01.2026 Przetwory owocowe i przetwory warzywne, Mleko i produkty mleczne, Slodycze i wyroby cukiernicze, Napoje bezalkoholowe, Przetwory zbozowe, Koncentraty spozywcze, Wyroby garmazeryjne, Suplementy diety Zawartosc substancji slodzacych\nZakres:\naspartam\nZakres (1,0 – 4000) mg/kg lub mg/l\nacesulfam-K (1,0 – 4000) mg/kg lub mg/l sacharyna i jej sole (1,0 – 4000) mg/kg lub mg/l\nMetoda chromatografii cieczowej z detekcja diodowa (HPLC-DAD) PB-PAZ/FS-46 wersja 01 z dnia 16.01.2026","categories":["food","pharma"],"row_index":205,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sweetener content","parameters_en":[{"name":"aspartame"},{"name":"Range","range":"(1,0 – 4000) mg/kg lub mg/l"},{"name":"acesulfam-K (1,0 – 4000) mg/kg lub mg/l sacharyna i jej sole (1,0 – 4000) mg/kg lub mg/l"}],"search_en":"Sweetener content Liquid chromatography with diode array detection (HPLC-DAD) aspartame Range PB-PAZ/FS-46 wersja 01 z dnia 16.01.2026","technique_en":"Liquid chromatography with diode array detection (HPLC-DAD)","parameters_zh":[{"name":"阿斯巴甜"},{"name":"范围","range":"(1,0 – 4000) mg/kg lub mg/l"},{"name":"acesulfam-K (1,0 – 4000) mg/kg lub mg/l sacharyna i jej sole (1,0 – 4000) mg/kg lub mg/l"}],"search_zh":"甜味剂含量 阿斯巴甜 范围 PB-PAZ/FS-46 wersja 01 z dnia 16.01.2026","methodology_zh":"甜味剂含量"},{"_id":"6a8369ecaf14b9c0e7b1dcf0","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Mięso i przetwory mięsne, Ryby i przetwory rybne, Owoce morza i przetwory, Wyroby garmażeryjne, Koncentraty spożywcze, Zboża i produkty zbożowe, Słodycze i wyroby cukiernicze, Wyroby ciastkarskie, Pieczywo, półprodukty i wyroby piekarnicze, Napoje bezalkoholowe, Napoje alkoholowe, Przetwory warzywno-owocowe, Jaja i produkty jajeczne, Mleko i przetwory mleczne, Nasiona oleiste, Bakalie i orzechy, Owoce i warzywa, Nasiona roślin strączkowych, Herbata, Kawa, Majonez, Musztarda, Sosy i dresingi, Produkty ziemniaczane i zbożowe, Suplementy diety i odżywki, Zioła i przyprawy, Grzyby i ich przetwory, Dodatki do żywności, Pasze","methodology":"Oznaczanie zawartości azotu","parameters":[{"name":"Zakres","range":"(0,02 - 14,8) %"},{"name":"Zawartość białka (z obliczeń)"}],"technique":"Metoda Duma","techniques":["Metoda Duma"],"computed":[],"activity":"Oznaczanie zawartości azotu\nZakres:\nZakres (0,02 - 14,8) %\nZawartość białka (z obliczeń)\nMetoda Duma","reference":"PB-PAZ/FS-36 wersja 02 z dnia 02.05.2022 r.","norm_bases":["PB-PAZ/FS-36 wersja 02 z dnia 02.05.2022 r."],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i przetwory mięsne, Ryby i przetwory rybne, Owoce morza i przetwory, Wyroby garmażeryjne, Koncentraty spożywcze, Zboża i produkty zbożowe, Słodycze i wyroby cukiernicze, Wyroby ciastkarskie, Pieczywo, półprodukty i wyroby piekarnicze, Napoje bezalkoholowe, Napoje alkoholowe, Przetwory warzywno-owocowe, Jaja i produkty jajeczne, Mleko i przetwory mleczne, Nasiona oleiste, Bakalie i orzechy, Owoce i warzywa, Nasiona roślin strączkowych, Herbata, Kawa, Majonez, Musztarda, Sosy i dresingi, Produkty ziemniaczane i zbożowe, Suplementy diety i odżywki, Zioła i przyprawy, Grzyby i ich przetwory, Dodatki do żywności, Pasze Oznaczanie zawartości azotu\nZakres:\nZakres (0,02 - 14,8) %\nZawartość białka (z obliczeń)\nMetoda Duma PB-PAZ/FS-36 wersja 02 z dnia 02.05.2022 r. Mieso i przetwory miesne, Ryby i przetwory rybne, Owoce morza i przetwory, Wyroby garmazeryjne, Koncentraty spozywcze, Zboza i produkty zbozowe, Slodycze i wyroby cukiernicze, Wyroby ciastkarskie, Pieczywo, polprodukty i wyroby piekarnicze, Napoje bezalkoholowe, Napoje alkoholowe, Przetwory warzywno-owocowe, Jaja i produkty jajeczne, Mleko i przetwory mleczne, Nasiona oleiste, Bakalie i orzechy, Owoce i warzywa, Nasiona roslin straczkowych, Herbata, Kawa, Majonez, Musztarda, Sosy i dresingi, Produkty ziemniaczane i zbozowe, Suplementy diety i odzywki, Ziola i przyprawy, Grzyby i ich przetwory, Dodatki do zywnosci, Pasze Oznaczanie zawartosci azotu\nZakres:\nZakres (0,02 - 14,8) %\nZawartosc bialka (z obliczen)\nMetoda Duma PB-PAZ/FS-36 wersja 02 z dnia 02.05.2022 r.","categories":["food","microbiology","pharma"],"row_index":206,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Determination of nitrogen content","parameters_en":[{"name":"Range","range":"(0,02 - 14,8) %"},{"name":"Protein content (calculated)"}],"search_en":"Meat and meat products, Fish and fish products, Seafood and seafood products, Delicatessen products, Food concentrates, Cereals and cereal products, Sweets and confectionery, Pastry products, Bread, semi-finished and bakery products, Non-alcoholic beverages, Alcoholic beverages, Vegetable and fruit products, Eggs and egg products, Milk and dairy products, Oilseeds, Dried fruit and nuts, Fruit and vegetables, Legume seeds, Tea, Coffee, Mayonnaise, Mustard, Sauces and dressings, Potato and cereal products, Food supplements and nutritional preparations, Herbs and spices, Mushrooms and their products, Food additives, Feed Determination of nitrogen content Dumas method Range Protein content (calculated) PB-PAZ/FS-36 wersja 02 z dnia 02.05.2022 r.","technique_en":"Dumas method","test_object_en":"Meat and meat products, Fish and fish products, Seafood and seafood products, Delicatessen products, Food concentrates, Cereals and cereal products, Sweets and confectionery, Pastry products, Bread, semi-finished and bakery products, Non-alcoholic beverages, Alcoholic beverages, Vegetable and fruit products, Eggs and egg products, Milk and dairy products, Oilseeds, Dried fruit and nuts, Fruit and vegetables, Legume seeds, Tea, Coffee, Mayonnaise, Mustard, Sauces and dressings, Potato and cereal products, Food supplements and nutritional preparations, Herbs and spices, Mushrooms and their products, Food additives, Feed","parameters_zh":[{"name":"范围","range":"(0,02 - 14,8) %"},{"name":"蛋白质含量（计算值）"}],"search_zh":"范围 蛋白质含量（计算值） PB-PAZ/FS-36 wersja 02 z dnia 02.05.2022 r."},{"_id":"6a8369ecaf14b9c0e7b1dcf1","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Zboża i przetwory zbożowe, koncentraty spożywcze przetwory owocowe, warzywne, owocowo-warzywne, zioła","methodology":"Zawartości zanieczyszczeń nieorganicznych, organicznych,","parameters":[{"name":"Zakres","range":"(0,15 - 5) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartości zanieczyszczeń nieorganicznych, organicznych,\nZakres (0,15 - 5) %\nMetoda wagowa","reference":"PB-PAZ/FS-20 wersja 01 z dnia 22.02.2021 r.","norm_bases":["PB-PAZ/FS-20 wersja 01 z dnia 22.02.2021 r."],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Zboża i przetwory zbożowe, koncentraty spożywcze przetwory owocowe, warzywne, owocowo-warzywne, zioła Zawartości zanieczyszczeń nieorganicznych, organicznych,\nZakres (0,15 - 5) %\nMetoda wagowa PB-PAZ/FS-20 wersja 01 z dnia 22.02.2021 r. Zboza i przetwory zbozowe, koncentraty spozywcze przetwory owocowe, warzywne, owocowo-warzywne, ziola Zawartosci zanieczyszczen nieorganicznych, organicznych,\nZakres (0,15 - 5) %\nMetoda wagowa PB-PAZ/FS-20 wersja 01 z dnia 22.02.2021 r.","categories":["other"],"row_index":207,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Contents of inorganic and organic impurities,","parameters_en":[{"name":"Range","range":"(0,15 - 5) %"}],"search_en":"Cereals and cereal products, food concentrates fruit, vegetable and fruit-vegetable preserves, herbs Contents of inorganic and organic impurities, Gravimetric method Range PB-PAZ/FS-20 wersja 01 z dnia 22.02.2021 r.","technique_en":"Gravimetric method","test_object_en":"Cereals and cereal products, food concentrates fruit, vegetable and fruit-vegetable preserves, herbs","parameters_zh":[{"name":"范围","range":"(0,15 - 5) %"}],"search_zh":"重量法 范围 PB-PAZ/FS-20 wersja 01 z dnia 22.02.2021 r.","technique_zh":"重量法"},{"_id":"6a8369ecaf14b9c0e7b1dcf2","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Zboża i przetwory zbożowe, koncentraty spożywcze, przetwory owocowe, warzywne, owocowo-warzywne, wyroby cukiernicze, przyprawy, zioła, bakalie, herbata, pasze","methodology":"Obecność szkodników i ich pozostałości","parameters":[],"technique":"Metoda odsiewania i ręcznego wybierania","techniques":["Metoda odsiewania i ręcznego wybierania"],"computed":[],"activity":"Obecność szkodników i ich pozostałości\nMetoda odsiewania i ręcznego wybierania","reference":"PB-PAZ/FS-20 wersja 01 z dnia 22.02.2021 r.","norm_bases":["PB-PAZ/FS-20 wersja 01 z dnia 22.02.2021 r."],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Zboża i przetwory zbożowe, koncentraty spożywcze, przetwory owocowe, warzywne, owocowo-warzywne, wyroby cukiernicze, przyprawy, zioła, bakalie, herbata, pasze Obecność szkodników i ich pozostałości\nMetoda odsiewania i ręcznego wybierania PB-PAZ/FS-20 wersja 01 z dnia 22.02.2021 r. Zboza i przetwory zbozowe, koncentraty spozywcze, przetwory owocowe, warzywne, owocowo-warzywne, wyroby cukiernicze, przyprawy, ziola, bakalie, herbata, pasze Obecnosc szkodnikow i ich pozostalosci\nMetoda odsiewania i recznego wybierania PB-PAZ/FS-20 wersja 01 z dnia 22.02.2021 r.","categories":["food"],"row_index":208,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of pests and their residues","search_en":"Cereals and cereal products, food concentrates, fruit, vegetable and fruit-vegetable preserves, confectionery products, spices, herbs, dried fruits and nuts, tea, feed Presence of pests and their residues Sieving and manual picking method PB-PAZ/FS-20 wersja 01 z dnia 22.02.2021 r.","technique_en":"Sieving and manual picking method","test_object_en":"Cereals and cereal products, food concentrates, fruit, vegetable and fruit-vegetable preserves, confectionery products, spices, herbs, dried fruits and nuts, tea, feed","methodology_zh":"虫害及其残留物的检出","search_zh":"虫害及其残留物的检出 PB-PAZ/FS-20 wersja 01 z dnia 22.02.2021 r."},{"_id":"6a8369ecaf14b9c0e7b1dcf3","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Oleje i tłuszcze roślinne i zwierzęce, tłuszcze paszowe, tłuszcze techniczne i tłuszcze surowe","methodology":"Zawartość zanieczyszczeń nierozpuszczalnych","parameters":[{"name":"Zakres","range":"(0,004 - 2,5) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość zanieczyszczeń nierozpuszczalnych\nZakres (0,004 - 2,5) %\nMetoda wagowa","reference":"PN-EN ISO 663:2017-03","norm_bases":["PN-EN ISO 663:2017-03"],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Oleje i tłuszcze roślinne i zwierzęce, tłuszcze paszowe, tłuszcze techniczne i tłuszcze surowe Zawartość zanieczyszczeń nierozpuszczalnych\nZakres (0,004 - 2,5) %\nMetoda wagowa PN-EN ISO 663:2017-03 Oleje i tluszcze roslinne i zwierzece, tluszcze paszowe, tluszcze techniczne i tluszcze surowe Zawartosc zanieczyszczen nierozpuszczalnych\nZakres (0,004 - 2,5) %\nMetoda wagowa PN-EN ISO 663:2017-03","categories":["food","petro"],"row_index":209,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Insoluble impurity content","parameters_en":[{"name":"Range","range":"(0,004 - 2,5) %"}],"search_en":"Vegetable and animal oils and fats, feed fats, technical fats and crude fats Insoluble impurity content Gravimetric method Range PN-EN ISO 663:2017-03","technique_en":"Gravimetric method","test_object_en":"Vegetable and animal oils and fats, feed fats, technical fats and crude fats","parameters_zh":[{"name":"范围","range":"(0,004 - 2,5) %"}],"search_zh":"不溶性杂质含量 重量法 范围 PN-EN ISO 663:2017-03","technique_zh":"重量法","methodology_zh":"不溶性杂质含量"},{"_id":"6a8369ecaf14b9c0e7b1dcf4","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Mleko i produkty mleczne","methodology":"Kwasowość ogólna","parameters":[{"name":"Zakres","range":"(1,15 - 86,00) °SH"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Kwasowość ogólna\nZakres (1,15 - 86,00) °SH\nMetoda miareczkowa","reference":"PB-PAZ/FS-07 wersja 01 z dnia 22.02.2021 r.","norm_bases":["PB-PAZ/FS-07 wersja 01 z dnia 22.02.2021 r."],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mleko i produkty mleczne Kwasowość ogólna\nZakres (1,15 - 86,00) °SH\nMetoda miareczkowa PB-PAZ/FS-07 wersja 01 z dnia 22.02.2021 r. Mleko i produkty mleczne Kwasowosc ogolna\nZakres (1,15 - 86,00) °SH\nMetoda miareczkowa PB-PAZ/FS-07 wersja 01 z dnia 22.02.2021 r.","categories":["food"],"row_index":210,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total acidity","parameters_en":[{"name":"Range","range":"(1,15 - 86,00) °SH"}],"search_en":"Milk and milk products Total acidity Titrimetric method Range PB-PAZ/FS-07 wersja 01 z dnia 22.02.2021 r.","technique_en":"Titrimetric method","test_object_en":"Milk and milk products","parameters_zh":[{"name":"范围","range":"(1,15 - 86,00) °SH"}],"search_zh":"乳与乳制品 总酸度 滴定法 范围 PB-PAZ/FS-07 wersja 01 z dnia 22.02.2021 r.","technique_zh":"滴定法","methodology_zh":"总酸度","test_object_zh":"乳与乳制品"},{"_id":"6a8369ecaf14b9c0e7b1dcf5","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Przetwory owocowe, warzywne, owocowo-warzywne, soki, nektary, napoje bezalkoholowe, syropy","methodology":"Ekstrakt ogólny","parameters":[{"name":"Zakres","range":"(0,2 - 64) °Bx (%)"}],"technique":"Metoda refraktometryczna","techniques":["Metoda refraktometryczna"],"computed":[],"activity":"Ekstrakt ogólny\nZakres (0,2 - 64) °Bx (%)\nMetoda refraktometryczna","reference":"PB-PAZ/FS-13 wersja 01 z dnia 22.02.2021 r.","norm_bases":["PB-PAZ/FS-13 wersja 01 z dnia 22.02.2021 r."],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przetwory owocowe, warzywne, owocowo-warzywne, soki, nektary, napoje bezalkoholowe, syropy Ekstrakt ogólny\nZakres (0,2 - 64) °Bx (%)\nMetoda refraktometryczna PB-PAZ/FS-13 wersja 01 z dnia 22.02.2021 r. Przetwory owocowe, warzywne, owocowo-warzywne, soki, nektary, napoje bezalkoholowe, syropy Ekstrakt ogolny\nZakres (0,2 - 64) °Bx (%)\nMetoda refraktometryczna PB-PAZ/FS-13 wersja 01 z dnia 22.02.2021 r.","categories":["food"],"row_index":211,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total extract","parameters_en":[{"name":"Range","range":"(0,2 - 64) °Bx (%)"}],"search_en":"Fruit, vegetable and fruit-vegetable preserves, juices, nectars, non-alcoholic beverages, syrups Total extract Refractometric method Range PB-PAZ/FS-13 wersja 01 z dnia 22.02.2021 r.","technique_en":"Refractometric method","test_object_en":"Fruit, vegetable and fruit-vegetable preserves, juices, nectars, non-alcoholic beverages, syrups","parameters_zh":[{"name":"范围","range":"(0,2 - 64) °Bx (%)"}],"search_zh":"总浸出物 折射法 范围 PB-PAZ/FS-13 wersja 01 z dnia 22.02.2021 r.","technique_zh":"折射法","methodology_zh":"总浸出物"},{"_id":"6a8369ecaf14b9c0e7b1dcf6","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Przetwory owocowe, warzywne, owocowo-warzywne, soki, nektary, napoje bezalkoholowe, syropy","methodology":"Zawartość cukrów redukujących","parameters":[{"name":"Zakres","range":"(0,5 - 60,0) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość cukrów redukujących\nZakres (0,5 - 60,0) %\nMetoda miareczkowa","reference":"PN-A-75101-07:1990","norm_bases":["PN-A-75101-07:1990"],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przetwory owocowe, warzywne, owocowo-warzywne, soki, nektary, napoje bezalkoholowe, syropy Zawartość cukrów redukujących\nZakres (0,5 - 60,0) %\nMetoda miareczkowa PN-A-75101-07:1990 Przetwory owocowe, warzywne, owocowo-warzywne, soki, nektary, napoje bezalkoholowe, syropy Zawartosc cukrow redukujacych\nZakres (0,5 - 60,0) %\nMetoda miareczkowa PN-A-75101-07:1990","categories":["food"],"row_index":212,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Reducing sugar content","parameters_en":[{"name":"Range","range":"(0,5 - 60,0) %"}],"search_en":"Fruit, vegetable and fruit-vegetable preserves, juices, nectars, non-alcoholic beverages, syrups Reducing sugar content Titrimetric method Range PN-A-75101-07:1990","technique_en":"Titrimetric method","test_object_en":"Fruit, vegetable and fruit-vegetable preserves, juices, nectars, non-alcoholic beverages, syrups","parameters_zh":[{"name":"范围","range":"(0,5 - 60,0) %"}],"search_zh":"还原糖含量 滴定法 范围 PN-A-75101-07:1990","technique_zh":"滴定法","methodology_zh":"还原糖含量"},{"_id":"6a8369ecaf14b9c0e7b1dcf7","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Wyroby cukiernicze","methodology":"Zawartość cukrów redukujących","parameters":[{"name":"Zakres","range":"(0,5 - 60,0) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość cukrów redukujących\nZakres (0,5 - 60,0) %\nMetoda miareczkowa","reference":"PN-A-88023:1961","norm_bases":["PN-A-88023:1961"],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby cukiernicze Zawartość cukrów redukujących\nZakres (0,5 - 60,0) %\nMetoda miareczkowa PN-A-88023:1961 Wyroby cukiernicze Zawartosc cukrow redukujacych\nZakres (0,5 - 60,0) %\nMetoda miareczkowa PN-A-88023:1961","categories":["food"],"row_index":213,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Reducing sugar content","parameters_en":[{"name":"Range","range":"(0,5 - 60,0) %"}],"search_en":"Confectionery products Reducing sugar content Titrimetric method Range PN-A-88023:1961","technique_en":"Titrimetric method","test_object_en":"Confectionery products","parameters_zh":[{"name":"范围","range":"(0,5 - 60,0) %"}],"search_zh":"糖果制品 还原糖含量 滴定法 范围 PN-A-88023:1961","technique_zh":"滴定法","test_object_zh":"糖果制品","methodology_zh":"还原糖含量"},{"_id":"6a8369ecaf14b9c0e7b1dcf8","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Smażone przekąski ziemniaczane, mrożone wyroby kulinarne, półprodukty ziemniaczane podsmażane, masło, margaryny i mixy","methodology":"Liczba nadtlenkowa wyekstrahowanego tłuszczu - liczba Lea","parameters":[{"name":"Zakres","range":"(0,5 - 10,5) liczba Lea"},{"name":"M e t o da miareczkowa"}],"technique":null,"techniques":[],"computed":[],"activity":"Liczba nadtlenkowa wyekstrahowanego tłuszczu - liczba Lea\nZakres:\nZakres (0,5 - 10,5) liczba Lea\nM e t o da miareczkowa","reference":"PB-PAZ/FS-17 wersja 01 z dnia 22.02.2021 r.","norm_bases":["PB-PAZ/FS-17 wersja 01 z dnia 22.02.2021 r."],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Smażone przekąski ziemniaczane, mrożone wyroby kulinarne, półprodukty ziemniaczane podsmażane, masło, margaryny i mixy Liczba nadtlenkowa wyekstrahowanego tłuszczu - liczba Lea\nZakres:\nZakres (0,5 - 10,5) liczba Lea\nM e t o da miareczkowa PB-PAZ/FS-17 wersja 01 z dnia 22.02.2021 r. Smazone przekaski ziemniaczane, mrozone wyroby kulinarne, polprodukty ziemniaczane podsmazane, maslo, margaryny i mixy Liczba nadtlenkowa wyekstrahowanego tluszczu - liczba Lea\nZakres:\nZakres (0,5 - 10,5) liczba Lea\nM e t o da miareczkowa PB-PAZ/FS-17 wersja 01 z dnia 22.02.2021 r.","categories":["other"],"row_index":214,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Peroxide value of extracted fat - Lea value","parameters_en":[{"name":"Range","range":"(0,5 - 10,5) liczba Lea"},{"name":"Titrimetric method"}],"search_en":"Fried potato snacks, frozen culinary products, par-fried potato semi-products, butter, margarines and blends Peroxide value of extracted fat - Lea value Range Titrimetric method PB-PAZ/FS-17 wersja 01 z dnia 22.02.2021 r.","test_object_en":"Fried potato snacks, frozen culinary products, par-fried potato semi-products, butter, margarines and blends","parameters_zh":[{"name":"范围","range":"(0,5 - 10,5) liczba Lea"},{"name":"M e t o da miareczkowa"}],"search_zh":"范围 PB-PAZ/FS-17 wersja 01 z dnia 22.02.2021 r."},{"_id":"6a8369ecaf14b9c0e7b1dcf9","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Mięso i produkty mięsne wyroby garmażeryjne owoce, warzywa, przetwory owocowe, warzywne owocowo- warzywne i warzywno-mięsne, żywność specjalnego przeznaczenia żywieniowego, mleko i produkty mleczne","methodology":"Zawartość azotanów i azotynów","parameters":[{"name":"azotyny","range":"(0,4 - 160) mg/kg"},{"name":"azotany","range":"(2,0 - 400) mg/kg"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość azotanów i azotynów\nZakres:\nazotyny (0,4 - 160) mg/kg\nazotany (2,0 - 400) mg/kg\nMetoda spektrofotometryczna","reference":"PB-PAZ/FS-22 wersja 01 z dnia 22.02.2021 r.","norm_bases":["PB-PAZ/FS-22 wersja 01 z dnia 22.02.2021 r."],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i produkty mięsne wyroby garmażeryjne owoce, warzywa, przetwory owocowe, warzywne owocowo- warzywne i warzywno-mięsne, żywność specjalnego przeznaczenia żywieniowego, mleko i produkty mleczne Zawartość azotanów i azotynów\nZakres:\nazotyny (0,4 - 160) mg/kg\nazotany (2,0 - 400) mg/kg\nMetoda spektrofotometryczna PB-PAZ/FS-22 wersja 01 z dnia 22.02.2021 r. Mieso i produkty miesne wyroby garmazeryjne owoce, warzywa, przetwory owocowe, warzywne owocowo- warzywne i warzywno-miesne, zywnosc specjalnego przeznaczenia zywieniowego, mleko i produkty mleczne Zawartosc azotanow i azotynow\nZakres:\nazotyny (0,4 - 160) mg/kg\nazotany (2,0 - 400) mg/kg\nMetoda spektrofotometryczna PB-PAZ/FS-22 wersja 01 z dnia 22.02.2021 r.","categories":["food"],"row_index":215,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate and nitrite content","parameters_en":[{"name":"nitrites","range":"(0,4 - 160) mg/kg"},{"name":"nitrates","range":"(2,0 - 400) mg/kg"}],"search_en":"Meat and meat products delicatessen products fruit, vegetables, fruit, vegetable, fruit- vegetable and vegetable-meat products, foodstuffs for particular nutritional uses, milk and dairy products Nitrate and nitrite content Spectrophotometric method nitrites nitrates PB-PAZ/FS-22 wersja 01 z dnia 22.02.2021 r.","technique_en":"Spectrophotometric method","test_object_en":"Meat and meat products delicatessen products fruit, vegetables, fruit, vegetable, fruit- vegetable and vegetable-meat products, foodstuffs for particular nutritional uses, milk and dairy products","search_zh":"硝酸盐与亚硝酸盐含量 分光光度法 亚硝酸盐 硝酸盐 PB-PAZ/FS-22 wersja 01 z dnia 22.02.2021 r.","technique_zh":"分光光度法","parameters_zh":[{"name":"亚硝酸盐","range":"(0,4 - 160) mg/kg"},{"name":"硝酸盐","range":"(2,0 - 400) mg/kg"}],"methodology_zh":"硝酸盐与亚硝酸盐含量"},{"_id":"6a8369ecaf14b9c0e7b1dcfa","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Mleko i produkty mleczne, przetwory owocowe, warzywne owocowo-warzywne i warzywno- mięsne, mięso i produkty mięsne zboża i przetwory zbożowe, słodycze, wyroby cukiernicze i ciastkarskie, tłuszcze roślinne i zwierzęce, wyroby garmażeryjne, ryby, przetwory rybne oraz owoce morza, Pasze","methodology":"Tłuszcz całkowity","parameters":[{"name":"Zakres","range":"(0,5 - 85) %"}],"technique":"Metoda ekstrakcyjno-wagowa","techniques":["Metoda ekstrakcyjno-wagowa"],"computed":[],"activity":"Tłuszcz całkowity\nZakres (0,5 - 85) %\nMetoda ekstrakcyjno-wagowa","reference":"PB-PAZ/FS-26 wersja 01 z dnia 22.02.2021 r.","norm_bases":["PB-PAZ/FS-26 wersja 01 z dnia 22.02.2021 r."],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mleko i produkty mleczne, przetwory owocowe, warzywne owocowo-warzywne i warzywno- mięsne, mięso i produkty mięsne zboża i przetwory zbożowe, słodycze, wyroby cukiernicze i ciastkarskie, tłuszcze roślinne i zwierzęce, wyroby garmażeryjne, ryby, przetwory rybne oraz owoce morza, Pasze Tłuszcz całkowity\nZakres (0,5 - 85) %\nMetoda ekstrakcyjno-wagowa PB-PAZ/FS-26 wersja 01 z dnia 22.02.2021 r. Mleko i produkty mleczne, przetwory owocowe, warzywne owocowo-warzywne i warzywno- miesne, mieso i produkty miesne zboza i przetwory zbozowe, slodycze, wyroby cukiernicze i ciastkarskie, tluszcze roslinne i zwierzece, wyroby garmazeryjne, ryby, przetwory rybne oraz owoce morza, Pasze Tluszcz calkowity\nZakres (0,5 - 85) %\nMetoda ekstrakcyjno-wagowa PB-PAZ/FS-26 wersja 01 z dnia 22.02.2021 r.","categories":["food"],"row_index":216,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total fat","parameters_en":[{"name":"Range","range":"(0,5 - 85) %"}],"search_en":"Milk and dairy products, fruit, vegetable, fruit-vegetable and vegetable-meat products, meat and meat products cereals and cereal products, sweets, confectionery and pastry products, vegetable and animal fats, delicatessen products, fish, fish products and seafood, Feed Total fat Extraction-gravimetric method Range PB-PAZ/FS-26 wersja 01 z dnia 22.02.2021 r.","technique_en":"Extraction-gravimetric method","test_object_en":"Milk and dairy products, fruit, vegetable, fruit-vegetable and vegetable-meat products, meat and meat products cereals and cereal products, sweets, confectionery and pastry products, vegetable and animal fats, delicatessen products, fish, fish products and seafood, Feed","parameters_zh":[{"name":"范围","range":"(0,5 - 85) %"}],"search_zh":"萃取-重量法 范围 PB-PAZ/FS-26 wersja 01 z dnia 22.02.2021 r.","technique_zh":"萃取-重量法"},{"_id":"6a8369ecaf14b9c0e7b1dcfb","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Pasze","methodology":"Zawartość azotu nierozpuszczalnego po traktowaniu pepsyną w rozcieńczonym HCl","parameters":[{"name":"Zakres","range":"(6,4 - 32,0) g/kg"},{"name":"Zawartość nierozpuszczalnego białka ogółem (z obliczeń)"}],"technique":"Metoda enzymatyczno-miareczkowa","techniques":["Metoda enzymatyczno-miareczkowa"],"computed":[],"activity":"Zawartość azotu nierozpuszczalnego po traktowaniu pepsyną w rozcieńczonym HCl\nZakres:\nZakres (6,4 - 32,0) g/kg\nZawartość nierozpuszczalnego białka ogółem (z obliczeń)\nMetoda enzymatyczno-miareczkowa","reference":"PN-ISO 6655:2000 pkt 8.4 z wył. pkt. 8.4.2 | PB-PAZ/FS-14 wersja 01 z dnia 22.02.2021 r.","norm_bases":["PN-ISO 6655:2000 pkt 8.4 z wył. pkt. 8.4.2","PB-PAZ/FS-14 wersja 01 z dnia 22.02.2021 r."],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pasze Zawartość azotu nierozpuszczalnego po traktowaniu pepsyną w rozcieńczonym HCl\nZakres:\nZakres (6,4 - 32,0) g/kg\nZawartość nierozpuszczalnego białka ogółem (z obliczeń)\nMetoda enzymatyczno-miareczkowa PN-ISO 6655:2000 pkt 8.4 z wył. pkt. 8.4.2 | PB-PAZ/FS-14 wersja 01 z dnia 22.02.2021 r. Pasze Zawartosc azotu nierozpuszczalnego po traktowaniu pepsyna w rozcienczonym HCl\nZakres:\nZakres (6,4 - 32,0) g/kg\nZawartosc nierozpuszczalnego bialka ogolem (z obliczen)\nMetoda enzymatyczno-miareczkowa PN-ISO 6655:2000 pkt 8.4 z wyl. pkt. 8.4.2 | PB-PAZ/FS-14 wersja 01 z dnia 22.02.2021 r.","categories":["food"],"row_index":217,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of nitrogen insoluble after pepsin treatment in dilute HCl","parameters_en":[{"name":"Range","range":"(6,4 - 32,0) g/kg"},{"name":"Content of total insoluble protein (calculated)"}],"search_en":"Feed Content of nitrogen insoluble after pepsin treatment in dilute HCl Enzymatic-titrimetric method Range Content of total insoluble protein (calculated) PN-ISO 6655:2000 pkt 8.4 z wył. pkt. 8.4.2 | PB-PAZ/FS-14 wersja 01 z dnia 22.02.2021 r.","technique_en":"Enzymatic-titrimetric method","test_object_en":"Feed","parameters_zh":[{"name":"范围","range":"(6,4 - 32,0) g/kg"},{"name":"Zawartość nierozpuszczalnego białka ogółem (z obliczeń)"}],"search_zh":"饲料 范围 PN-ISO 6655:2000 pkt 8.4 z wył. pkt. 8.4.2 | PB-PAZ/FS-14 wersja 01 z dnia 22.02.2021 r.","test_object_zh":"饲料"},{"_id":"6a8369ecaf14b9c0e7b1dcfc","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Pasze","methodology":"Zawartość rozpuszczalnego białka ogółem (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość rozpuszczalnego białka ogółem (z obliczeń)","reference":"PB-PAZ/FS-30 wersja 01 z dnia 04.03.2021 r.","norm_bases":["PB-PAZ/FS-30 wersja 01 z dnia 04.03.2021 r."],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pasze Zawartość rozpuszczalnego białka ogółem (z obliczeń) PB-PAZ/FS-30 wersja 01 z dnia 04.03.2021 r. Pasze Zawartosc rozpuszczalnego bialka ogolem (z obliczen) PB-PAZ/FS-30 wersja 01 z dnia 04.03.2021 r.","categories":["food"],"row_index":218,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of total soluble protein (calculated)","search_en":"Feed Content of total soluble protein (calculated) PB-PAZ/FS-30 wersja 01 z dnia 04.03.2021 r.","test_object_en":"Feed","search_zh":"饲料 PB-PAZ/FS-30 wersja 01 z dnia 04.03.2021 r.","test_object_zh":"饲料"},{"_id":"6a8369ecaf14b9c0e7b1dcfd","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Pasze","methodology":"Strawność białka (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Strawność białka (z obliczeń)","reference":"PB-PAZ/FS-30 wersja 01 z dnia 04.03.2021 r.","norm_bases":["PB-PAZ/FS-30 wersja 01 z dnia 04.03.2021 r."],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pasze Strawność białka (z obliczeń) PB-PAZ/FS-30 wersja 01 z dnia 04.03.2021 r. Pasze Strawnosc bialka (z obliczen) PB-PAZ/FS-30 wersja 01 z dnia 04.03.2021 r.","categories":["food"],"row_index":219,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Protein digestibility (calculated)","search_en":"Feed Protein digestibility (calculated) PB-PAZ/FS-30 wersja 01 z dnia 04.03.2021 r.","test_object_en":"Feed","search_zh":"饲料 PB-PAZ/FS-30 wersja 01 z dnia 04.03.2021 r.","test_object_zh":"饲料"},{"_id":"6a8369ecaf14b9c0e7b1dcfe","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Pasze","methodology":"Zawartość tłuszczu całkowitego (surowego)","parameters":[{"name":"Zakres","range":"(2 - 99,6) %"}],"technique":"Metoda ekstrakcyjno-wagowa (Soxhleta)","techniques":["Metoda ekstrakcyjno-wagowa (Soxhleta)"],"computed":[],"activity":"Zawartość tłuszczu całkowitego (surowego)\nZakres (2 - 99,6) %\nMetoda ekstrakcyjno-wagowa (Soxhleta)","reference":"PB-PAZ/FS-05 wersja 01 z dnia 22.02.2021 r.","norm_bases":["PB-PAZ/FS-05 wersja 01 z dnia 22.02.2021 r."],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pasze Zawartość tłuszczu całkowitego (surowego)\nZakres (2 - 99,6) %\nMetoda ekstrakcyjno-wagowa (Soxhleta) PB-PAZ/FS-05 wersja 01 z dnia 22.02.2021 r. Pasze Zawartosc tluszczu calkowitego (surowego)\nZakres (2 - 99,6) %\nMetoda ekstrakcyjno-wagowa (Soxhleta) PB-PAZ/FS-05 wersja 01 z dnia 22.02.2021 r.","categories":["food"],"row_index":220,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total (crude) fat content","parameters_en":[{"name":"Range","range":"(2 - 99,6) %"}],"search_en":"Feed Total (crude) fat content Extraction-gravimetric method (Soxhlet) Range PB-PAZ/FS-05 wersja 01 z dnia 22.02.2021 r.","technique_en":"Extraction-gravimetric method (Soxhlet)","test_object_en":"Feed","parameters_zh":[{"name":"范围","range":"(2 - 99,6) %"}],"search_zh":"饲料 萃取-重量法（索氏抽提） 范围 PB-PAZ/FS-05 wersja 01 z dnia 22.02.2021 r.","test_object_zh":"饲料","technique_zh":"萃取-重量法（索氏抽提）"},{"_id":"6a8369ecaf14b9c0e7b1dcff","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Pasze","methodology":"Zawartość chlorku sodu (NaCl)","parameters":[{"name":"Zakres","range":"(0,1 - 25) %"}],"technique":"Metoda miareczkowa (Volharda i Mohra)","techniques":["Metoda miareczkowa (Volharda i Mohra)"],"computed":[],"activity":"Zawartość chlorku sodu (NaCl)\nZakres (0,1 - 25) %\nMetoda miareczkowa (Volharda i Mohra)","reference":"PB-PAZ/FS-09 wersja 01 Z dnia 22.02.2021 r.","norm_bases":["PB-PAZ/FS-09 wersja 01 Z dnia 22.02.2021 r."],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pasze Zawartość chlorku sodu (NaCl)\nZakres (0,1 - 25) %\nMetoda miareczkowa (Volharda i Mohra) PB-PAZ/FS-09 wersja 01 Z dnia 22.02.2021 r. Pasze Zawartosc chlorku sodu (NaCl)\nZakres (0,1 - 25) %\nMetoda miareczkowa (Volharda i Mohra) PB-PAZ/FS-09 wersja 01 Z dnia 22.02.2021 r.","categories":["food"],"row_index":221,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sodium chloride content (NaCl)","parameters_en":[{"name":"Range","range":"(0,1 - 25) %"}],"search_en":"Feed Sodium chloride content (NaCl) Titrimetric method (Volhard and Mohr) Range PB-PAZ/FS-09 wersja 01 Z dnia 22.02.2021 r.","technique_en":"Titrimetric method (Volhard and Mohr)","test_object_en":"Feed","parameters_zh":[{"name":"范围","range":"(0,1 - 25) %"}],"search_zh":"饲料 范围 PB-PAZ/FS-09 wersja 01 Z dnia 22.02.2021 r.","test_object_zh":"饲料"},{"_id":"6a8369ecaf14b9c0e7b1dd00","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Pasze","methodology":"Oznaczanie zawartości butylohydroksyanizolu (BHA)","parameters":[{"name":"Zakres","range":"(5,00 - 400,00) mg/kg"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV/VIS)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV/VIS)"],"computed":[],"activity":"Oznaczanie zawartości butylohydroksyanizolu (BHA)\nZakres (5,00 - 400,00) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV/VIS)","reference":"PB-PAZ/FS-38 wersja 01 z dnia 03.11.2022 r.","norm_bases":["PB-PAZ/FS-38 wersja 01 z dnia 03.11.2022 r."],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pasze Oznaczanie zawartości butylohydroksyanizolu (BHA)\nZakres (5,00 - 400,00) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV/VIS) PB-PAZ/FS-38 wersja 01 z dnia 03.11.2022 r. Pasze Oznaczanie zawartosci butylohydroksyanizolu (BHA)\nZakres (5,00 - 400,00) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC-UV/VIS) PB-PAZ/FS-38 wersja 01 z dnia 03.11.2022 r.","categories":["food"],"row_index":222,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Determination of butylated hydroxyanisole (BHA) content","parameters_en":[{"name":"Range","range":"(5,00 - 400,00) mg/kg"}],"search_en":"Feed Determination of butylated hydroxyanisole (BHA) content High-performance liquid chromatography with spectrophotometric detection (HPLC-UV/VIS) Range PB-PAZ/FS-38 wersja 01 z dnia 03.11.2022 r.","technique_en":"High-performance liquid chromatography with spectrophotometric detection (HPLC-UV/VIS)","test_object_en":"Feed","parameters_zh":[{"name":"范围","range":"(5,00 - 400,00) mg/kg"}],"search_zh":"饲料 高效液相色谱-分光光度检测法（HPLC-UV/VIS） 范围 PB-PAZ/FS-38 wersja 01 z dnia 03.11.2022 r.","test_object_zh":"饲料","technique_zh":"高效液相色谱-分光光度检测法（HPLC-UV/VIS）"},{"_id":"6a8369ecaf14b9c0e7b1dd01","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Pasze","methodology":"Oznaczanie zawartości butylohydroksytoluenu (BHT)","parameters":[{"name":"Zakres","range":"(5,00 - 400,00) mg/kg"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV/VIS)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV/VIS)"],"computed":[],"activity":"Oznaczanie zawartości butylohydroksytoluenu (BHT)\nZakres (5,00 - 400,00) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV/VIS)","reference":"PB-PAZ/FS-38 wersja 01 z dnia 03.11.2022 r.","norm_bases":["PB-PAZ/FS-38 wersja 01 z dnia 03.11.2022 r."],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pasze Oznaczanie zawartości butylohydroksytoluenu (BHT)\nZakres (5,00 - 400,00) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV/VIS) PB-PAZ/FS-38 wersja 01 z dnia 03.11.2022 r. Pasze Oznaczanie zawartosci butylohydroksytoluenu (BHT)\nZakres (5,00 - 400,00) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC-UV/VIS) PB-PAZ/FS-38 wersja 01 z dnia 03.11.2022 r.","categories":["food"],"row_index":223,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Determination of butylated hydroxytoluene (BHT) content","parameters_en":[{"name":"Range","range":"(5,00 - 400,00) mg/kg"}],"search_en":"Feed Determination of butylated hydroxytoluene (BHT) content High-performance liquid chromatography with spectrophotometric detection (HPLC-UV/VIS) Range PB-PAZ/FS-38 wersja 01 z dnia 03.11.2022 r.","technique_en":"High-performance liquid chromatography with spectrophotometric detection (HPLC-UV/VIS)","test_object_en":"Feed","parameters_zh":[{"name":"范围","range":"(5,00 - 400,00) mg/kg"}],"search_zh":"饲料 高效液相色谱-分光光度检测法（HPLC-UV/VIS） 范围 PB-PAZ/FS-38 wersja 01 z dnia 03.11.2022 r.","test_object_zh":"饲料","technique_zh":"高效液相色谱-分光光度检测法（HPLC-UV/VIS）"},{"_id":"6a8369ecaf14b9c0e7b1dd02","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Wyroby garmażeryjne, ryby i przetwory rybne, owoce morza i ich przetwory, mleko i produkty mleczne, mięso i produkty mięsne, jaja i produkty jajeczne, nasiona roślin strączkowych, przetwory zbożowe","methodology":"Zawartość cukrów ogółem","parameters":[{"name":"Zakres","range":"(0,2 - 55) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość cukrów ogółem\nZakres (0,2 - 55) %\nMetoda miareczkowa","reference":"PB-PAZ/FS-29 wersja 01 z dnia 22.02.2021 r.","norm_bases":["PB-PAZ/FS-29 wersja 01 z dnia 22.02.2021 r."],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby garmażeryjne, ryby i przetwory rybne, owoce morza i ich przetwory, mleko i produkty mleczne, mięso i produkty mięsne, jaja i produkty jajeczne, nasiona roślin strączkowych, przetwory zbożowe Zawartość cukrów ogółem\nZakres (0,2 - 55) %\nMetoda miareczkowa PB-PAZ/FS-29 wersja 01 z dnia 22.02.2021 r. Wyroby garmazeryjne, ryby i przetwory rybne, owoce morza i ich przetwory, mleko i produkty mleczne, mieso i produkty miesne, jaja i produkty jajeczne, nasiona roslin straczkowych, przetwory zbozowe Zawartosc cukrow ogolem\nZakres (0,2 - 55) %\nMetoda miareczkowa PB-PAZ/FS-29 wersja 01 z dnia 22.02.2021 r.","categories":["food"],"row_index":224,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total sugar content","parameters_en":[{"name":"Range","range":"(0,2 - 55) %"}],"search_en":"Delicatessen products, fish and fish products, seafood and their products, milk and milk products, meat and meat products, eggs and egg products, legume seeds, cereal products Total sugar content Titrimetric method Range PB-PAZ/FS-29 wersja 01 z dnia 22.02.2021 r.","technique_en":"Titrimetric method","test_object_en":"Delicatessen products, fish and fish products, seafood and their products, milk and milk products, meat and meat products, eggs and egg products, legume seeds, cereal products","parameters_zh":[{"name":"范围","range":"(0,2 - 55) %"}],"search_zh":"总糖含量 滴定法 范围 PB-PAZ/FS-29 wersja 01 z dnia 22.02.2021 r.","technique_zh":"滴定法","methodology_zh":"总糖含量"},{"_id":"6a8369ecaf14b9c0e7b1dd03","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Wyroby garmażeryjne","methodology":"Zawartość cukrów ogółem","parameters":[{"name":"Zakres","range":"(0,5 - 20) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość cukrów ogółem\nZakres (0,5 - 20) %\nMetoda miareczkowa","reference":"PN-A-82100:1985","norm_bases":["PN-A-82100:1985"],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby garmażeryjne Zawartość cukrów ogółem\nZakres (0,5 - 20) %\nMetoda miareczkowa PN-A-82100:1985 Wyroby garmazeryjne Zawartosc cukrow ogolem\nZakres (0,5 - 20) %\nMetoda miareczkowa PN-A-82100:1985","categories":["other"],"row_index":225,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total sugar content","parameters_en":[{"name":"Range","range":"(0,5 - 20) %"}],"search_en":"Delicatessen products Total sugar content Titrimetric method Range PN-A-82100:1985","technique_en":"Titrimetric method","test_object_en":"Delicatessen products","parameters_zh":[{"name":"范围","range":"(0,5 - 20) %"}],"search_zh":"熟食制品 总糖含量 滴定法 范围 PN-A-82100:1985","technique_zh":"滴定法","test_object_zh":"熟食制品","methodology_zh":"总糖含量"},{"_id":"6a8369ecaf14b9c0e7b1dd04","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Przetwory owocowe, warzywne, owocowo-warzywne, soki, nektary, napoje bezalkoholowe, syropy","methodology":"Zawartość cukrów ogółem","parameters":[{"name":"Zakres","range":"(0,5 - 85) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość cukrów ogółem\nZakres (0,5 - 85) %\nMetoda miareczkowa","reference":"PN-A-75101-07:1990","norm_bases":["PN-A-75101-07:1990"],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przetwory owocowe, warzywne, owocowo-warzywne, soki, nektary, napoje bezalkoholowe, syropy Zawartość cukrów ogółem\nZakres (0,5 - 85) %\nMetoda miareczkowa PN-A-75101-07:1990 Przetwory owocowe, warzywne, owocowo-warzywne, soki, nektary, napoje bezalkoholowe, syropy Zawartosc cukrow ogolem\nZakres (0,5 - 85) %\nMetoda miareczkowa PN-A-75101-07:1990","categories":["food"],"row_index":226,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total sugar content","parameters_en":[{"name":"Range","range":"(0,5 - 85) %"}],"search_en":"Fruit, vegetable and fruit-vegetable preserves, juices, nectars, non-alcoholic beverages, syrups Total sugar content Titrimetric method Range PN-A-75101-07:1990","technique_en":"Titrimetric method","test_object_en":"Fruit, vegetable and fruit-vegetable preserves, juices, nectars, non-alcoholic beverages, syrups","parameters_zh":[{"name":"范围","range":"(0,5 - 85) %"}],"search_zh":"总糖含量 滴定法 范围 PN-A-75101-07:1990","technique_zh":"滴定法","methodology_zh":"总糖含量"},{"_id":"6a8369ecaf14b9c0e7b1dd05","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Wyroby i półprodukty ciastkarskie","methodology":"Zawartość cukrów ogółem","parameters":[{"name":"Zakres","range":"(0,5 - 85) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość cukrów ogółem\nZakres (0,5 - 85) %\nMetoda miareczkowa","reference":"PN-A-74252:1998","norm_bases":["PN-A-74252:1998"],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby i półprodukty ciastkarskie Zawartość cukrów ogółem\nZakres (0,5 - 85) %\nMetoda miareczkowa PN-A-74252:1998 Wyroby i polprodukty ciastkarskie Zawartosc cukrow ogolem\nZakres (0,5 - 85) %\nMetoda miareczkowa PN-A-74252:1998","categories":["other"],"row_index":227,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total sugar content","parameters_en":[{"name":"Range","range":"(0,5 - 85) %"}],"search_en":"Pastry products and semi-products Total sugar content Titrimetric method Range PN-A-74252:1998","technique_en":"Titrimetric method","test_object_en":"Pastry products and semi-products","parameters_zh":[{"name":"范围","range":"(0,5 - 85) %"}],"search_zh":"糕点制品与半成品 总糖含量 滴定法 范围 PN-A-74252:1998","technique_zh":"滴定法","methodology_zh":"总糖含量","test_object_zh":"糕点制品与半成品"},{"_id":"6a8369ecaf14b9c0e7b1dd06","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Wyroby cukiernicze","methodology":"Zawartość cukrów ogółem","parameters":[{"name":"Zakres","range":"(0,5 - 85) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość cukrów ogółem\nZakres (0,5 - 85) %\nMetoda miareczkowa","reference":"PN-A-88023:1961","norm_bases":["PN-A-88023:1961"],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby cukiernicze Zawartość cukrów ogółem\nZakres (0,5 - 85) %\nMetoda miareczkowa PN-A-88023:1961 Wyroby cukiernicze Zawartosc cukrow ogolem\nZakres (0,5 - 85) %\nMetoda miareczkowa PN-A-88023:1961","categories":["food"],"row_index":228,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total sugar content","parameters_en":[{"name":"Range","range":"(0,5 - 85) %"}],"search_en":"Confectionery products Total sugar content Titrimetric method Range PN-A-88023:1961","technique_en":"Titrimetric method","test_object_en":"Confectionery products","parameters_zh":[{"name":"范围","range":"(0,5 - 85) %"}],"search_zh":"糖果制品 总糖含量 滴定法 范围 PN-A-88023:1961","technique_zh":"滴定法","test_object_zh":"糖果制品","methodology_zh":"总糖含量"},{"_id":"6a8369ecaf14b9c0e7b1dd07","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Pieczywo i półprodukty piekarnicze, pieczywo słodkie","methodology":"Zawartość cukrów ogółem w przeliczeniu na suchą masę","parameters":[{"name":"Zakres","range":"(1 - 15) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość cukrów ogółem w przeliczeniu na suchą masę\nZakres (1 - 15) %\nMetoda miareczkowa","reference":"PN-A-74108:1996","norm_bases":["PN-A-74108:1996"],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pieczywo i półprodukty piekarnicze, pieczywo słodkie Zawartość cukrów ogółem w przeliczeniu na suchą masę\nZakres (1 - 15) %\nMetoda miareczkowa PN-A-74108:1996 Pieczywo i polprodukty piekarnicze, pieczywo slodkie Zawartosc cukrow ogolem w przeliczeniu na sucha mase\nZakres (1 - 15) %\nMetoda miareczkowa PN-A-74108:1996","categories":["other"],"row_index":229,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total sugar content calculated on dry matter","parameters_en":[{"name":"Range","range":"(1 - 15) %"}],"search_en":"Bread and bakery semi-products, sweet bread Total sugar content calculated on dry matter Titrimetric method Range PN-A-74108:1996","technique_en":"Titrimetric method","test_object_en":"Bread and bakery semi-products, sweet bread","parameters_zh":[{"name":"范围","range":"(1 - 15) %"}],"search_zh":"滴定法 范围 PN-A-74108:1996","technique_zh":"滴定法"},{"_id":"6a8369ecaf14b9c0e7b1dd08","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Pieczywo i półprodukty piekarnicze, pieczywo słodkie","methodology":"Zawartość cukrów ogółem (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość cukrów ogółem (z obliczeń)","reference":"PN-A-74108:1996","norm_bases":["PN-A-74108:1996"],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pieczywo i półprodukty piekarnicze, pieczywo słodkie Zawartość cukrów ogółem (z obliczeń) PN-A-74108:1996 Pieczywo i polprodukty piekarnicze, pieczywo slodkie Zawartosc cukrow ogolem (z obliczen) PN-A-74108:1996","categories":["other"],"row_index":230,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total sugar content (calculated)","search_en":"Bread and bakery semi-products, sweet bread Total sugar content (calculated) PN-A-74108:1996","test_object_en":"Bread and bakery semi-products, sweet bread"},{"_id":"6a8369ecaf14b9c0e7b1dd09","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Koncentraty spożywcze","methodology":"Zawartość cukrów ogółem w przeliczeniu na sacharozę","parameters":[{"name":"Zakres","range":"(0,5 - 85) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość cukrów ogółem w przeliczeniu na sacharozę\nZakres (0,5 - 85) %\nMetoda miareczkowa","reference":"PN-A-79011-5:1998","norm_bases":["PN-A-79011-5:1998"],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Koncentraty spożywcze Zawartość cukrów ogółem w przeliczeniu na sacharozę\nZakres (0,5 - 85) %\nMetoda miareczkowa PN-A-79011-5:1998 Koncentraty spozywcze Zawartosc cukrow ogolem w przeliczeniu na sacharoze\nZakres (0,5 - 85) %\nMetoda miareczkowa PN-A-79011-5:1998","categories":["other"],"row_index":231,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total sugar content calculated as sucrose","parameters_en":[{"name":"Range","range":"(0,5 - 85) %"}],"search_en":"Food concentrates Total sugar content calculated as sucrose Titrimetric method Range PN-A-79011-5:1998","technique_en":"Titrimetric method","test_object_en":"Food concentrates","parameters_zh":[{"name":"范围","range":"(0,5 - 85) %"}],"search_zh":"食品浓缩制品 滴定法 范围 PN-A-79011-5:1998","technique_zh":"滴定法","test_object_zh":"食品浓缩制品"},{"_id":"6a8369ecaf14b9c0e7b1dd0a","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Koncentraty spożywcze","methodology":"Zawartość cukrów ogółem (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość cukrów ogółem (z obliczeń)","reference":"PN-A-79011-5:1998","norm_bases":["PN-A-79011-5:1998"],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Koncentraty spożywcze Zawartość cukrów ogółem (z obliczeń) PN-A-79011-5:1998 Koncentraty spozywcze Zawartosc cukrow ogolem (z obliczen) PN-A-79011-5:1998","categories":["other"],"row_index":232,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total sugar content (calculated)","search_en":"Food concentrates Total sugar content (calculated) PN-A-79011-5:1998","test_object_en":"Food concentrates","search_zh":"食品浓缩制品 PN-A-79011-5:1998","test_object_zh":"食品浓缩制品"},{"_id":"6a8369ecaf14b9c0e7b1dd0b","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Nasiona oleiste","methodology":"Zawartość oleju","parameters":[{"name":"Zakres","range":"(38 - 66) %"}],"technique":"Metoda ekstrakcyjno-wagowa (Soxhlet)","techniques":["Metoda ekstrakcyjno-wagowa (Soxhlet)"],"computed":[],"activity":"Zawartość oleju\nZakres (38 - 66) %\nMetoda ekstrakcyjno-wagowa (Soxhlet)","reference":"PB-PAZ/FS-05 wersja 01 z dnia 22.02.2021 r.","norm_bases":["PB-PAZ/FS-05 wersja 01 z dnia 22.02.2021 r."],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Nasiona oleiste Zawartość oleju\nZakres (38 - 66) %\nMetoda ekstrakcyjno-wagowa (Soxhlet) PB-PAZ/FS-05 wersja 01 z dnia 22.02.2021 r. Nasiona oleiste Zawartosc oleju\nZakres (38 - 66) %\nMetoda ekstrakcyjno-wagowa (Soxhlet) PB-PAZ/FS-05 wersja 01 z dnia 22.02.2021 r.","categories":["petro"],"row_index":233,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Oil content","parameters_en":[{"name":"Range","range":"(38 - 66) %"}],"search_en":"Oilseeds Oil content Extraction-gravimetric method (Soxhlet) Range PB-PAZ/FS-05 wersja 01 z dnia 22.02.2021 r.","technique_en":"Extraction-gravimetric method (Soxhlet)","test_object_en":"Oilseeds","parameters_zh":[{"name":"范围","range":"(38 - 66) %"}],"search_zh":"油料种子 含油量 范围 PB-PAZ/FS-05 wersja 01 z dnia 22.02.2021 r.","test_object_zh":"油料种子","methodology_zh":"含油量"},{"_id":"6a8369ecaf14b9c0e7b1dd0c","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Napoje bezalkoholowe","methodology":"Zawartość alkoholu etylowego","parameters":[{"name":"Zakres","range":"(0,05 - 2,0) %"}],"technique":"Metoda destylacyjno-oscylacyjna","techniques":["Metoda destylacyjno-oscylacyjna"],"computed":[],"activity":"Zawartość alkoholu etylowego\nZakres (0,05 - 2,0) %\nMetoda destylacyjno-oscylacyjna","reference":"PN-A-79033:1985 p. 3.14 | PB-PAZ/FS-32 wersja 01 z dnia 22.02.2021 r.","norm_bases":["PN-A-79033:1985 p. 3.14","PB-PAZ/FS-32 wersja 01 z dnia 22.02.2021 r."],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Napoje bezalkoholowe Zawartość alkoholu etylowego\nZakres (0,05 - 2,0) %\nMetoda destylacyjno-oscylacyjna PN-A-79033:1985 p. 3.14 | PB-PAZ/FS-32 wersja 01 z dnia 22.02.2021 r. Napoje bezalkoholowe Zawartosc alkoholu etylowego\nZakres (0,05 - 2,0) %\nMetoda destylacyjno-oscylacyjna PN-A-79033:1985 p. 3.14 | PB-PAZ/FS-32 wersja 01 z dnia 22.02.2021 r.","categories":["food"],"row_index":234,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ethyl alcohol content","parameters_en":[{"name":"Range","range":"(0,05 - 2,0) %"}],"search_en":"Non-alcoholic beverages Ethyl alcohol content Distillation-oscillation method Range PN-A-79033:1985 p. 3.14 | PB-PAZ/FS-32 wersja 01 z dnia 22.02.2021 r.","technique_en":"Distillation-oscillation method","test_object_en":"Non-alcoholic beverages","parameters_zh":[{"name":"范围","range":"(0,05 - 2,0) %"}],"search_zh":"无酒精饮料 乙醇含量 蒸馏-振荡法 范围 PN-A-79033:1985 p. 3.14 | PB-PAZ/FS-32 wersja 01 z dnia 22.02.2021 r.","test_object_zh":"无酒精饮料","methodology_zh":"乙醇含量","technique_zh":"蒸馏-振荡法"},{"_id":"6a8369ecaf14b9c0e7b1dd0d","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Napoje bezalkoholowe","methodology":"Kwasowość lotna","parameters":[{"name":"Zakres","range":"(0,04 - 0,30) %"}],"technique":"Metoda destylacyjno-miareczkowa","techniques":["Metoda destylacyjno-miareczkowa"],"computed":[],"activity":"Kwasowość lotna\nZakres (0,04 - 0,30) %\nMetoda destylacyjno-miareczkowa","reference":"PN-A-79033:1985 p. 3.9","norm_bases":["PN-A-79033:1985 p. 3.9"],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Napoje bezalkoholowe Kwasowość lotna\nZakres (0,04 - 0,30) %\nMetoda destylacyjno-miareczkowa PN-A-79033:1985 p. 3.9 Napoje bezalkoholowe Kwasowosc lotna\nZakres (0,04 - 0,30) %\nMetoda destylacyjno-miareczkowa PN-A-79033:1985 p. 3.9","categories":["food"],"row_index":235,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Volatile acidity","parameters_en":[{"name":"Range","range":"(0,04 - 0,30) %"}],"search_en":"Non-alcoholic beverages Volatile acidity Distillation-titrimetric method Range PN-A-79033:1985 p. 3.9","technique_en":"Distillation-titrimetric method","test_object_en":"Non-alcoholic beverages","parameters_zh":[{"name":"范围","range":"(0,04 - 0,30) %"}],"search_zh":"无酒精饮料 挥发酸 蒸馏-滴定法 范围 PN-A-79033:1985 p. 3.9","test_object_zh":"无酒精饮料","methodology_zh":"挥发酸","technique_zh":"蒸馏-滴定法"},{"_id":"6a8369ecaf14b9c0e7b1dd0e","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Przetwory owocowe, warzywne, owocowo-warzywne, soki, nektary, syropy, zaprawy","methodology":"Kwasowość lotna","parameters":[{"name":"Zakres","range":"(0,04 - 0,30) %"}],"technique":"Metoda destylacyjno-miareczkowa","techniques":["Metoda destylacyjno-miareczkowa"],"computed":[],"activity":"Kwasowość lotna\nZakres (0,04 - 0,30) %\nMetoda destylacyjno-miareczkowa","reference":"PN-A-75101-05:1990","norm_bases":["PN-A-75101-05:1990"],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przetwory owocowe, warzywne, owocowo-warzywne, soki, nektary, syropy, zaprawy Kwasowość lotna\nZakres (0,04 - 0,30) %\nMetoda destylacyjno-miareczkowa PN-A-75101-05:1990 Przetwory owocowe, warzywne, owocowo-warzywne, soki, nektary, syropy, zaprawy Kwasowosc lotna\nZakres (0,04 - 0,30) %\nMetoda destylacyjno-miareczkowa PN-A-75101-05:1990","categories":["other"],"row_index":236,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Volatile acidity","parameters_en":[{"name":"Range","range":"(0,04 - 0,30) %"}],"search_en":"Fruit, vegetable and fruit-vegetable products, juices, nectars, syrups, beverage bases Volatile acidity Distillation-titrimetric method Range PN-A-75101-05:1990","technique_en":"Distillation-titrimetric method","test_object_en":"Fruit, vegetable and fruit-vegetable products, juices, nectars, syrups, beverage bases","parameters_zh":[{"name":"范围","range":"(0,04 - 0,30) %"}],"search_zh":"挥发酸 蒸馏-滴定法 范围 PN-A-75101-05:1990","methodology_zh":"挥发酸","technique_zh":"蒸馏-滴定法"},{"_id":"6a8369ecaf14b9c0e7b1dd0f","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Przetwory owocowe, warzywne, owocowo-warzywne, soki, nektary, syropy, zaprawy","methodology":"Zawartość alkoholu etylowego","parameters":[{"name":"Zakres","range":"(0,05 - 3,5) %"}],"technique":"Metoda destylacyjno-oscylacyjna","techniques":["Metoda destylacyjno-oscylacyjna"],"computed":[],"activity":"Zawartość alkoholu etylowego\nZakres (0,05 - 3,5) %\nMetoda destylacyjno-oscylacyjna","reference":"PN-A-75101-09:1990 | PB-PAZ/FS-32 wersja 01 z dnia 22.02.2021 r.","norm_bases":["PN-A-75101-09:1990","PB-PAZ/FS-32 wersja 01 z dnia 22.02.2021 r."],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przetwory owocowe, warzywne, owocowo-warzywne, soki, nektary, syropy, zaprawy Zawartość alkoholu etylowego\nZakres (0,05 - 3,5) %\nMetoda destylacyjno-oscylacyjna PN-A-75101-09:1990 | PB-PAZ/FS-32 wersja 01 z dnia 22.02.2021 r. Przetwory owocowe, warzywne, owocowo-warzywne, soki, nektary, syropy, zaprawy Zawartosc alkoholu etylowego\nZakres (0,05 - 3,5) %\nMetoda destylacyjno-oscylacyjna PN-A-75101-09:1990 | PB-PAZ/FS-32 wersja 01 z dnia 22.02.2021 r.","categories":["other"],"row_index":237,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ethyl alcohol content","parameters_en":[{"name":"Range","range":"(0,05 - 3,5) %"}],"search_en":"Fruit, vegetable and fruit-vegetable products, juices, nectars, syrups, beverage bases Ethyl alcohol content Distillation-oscillation method Range PN-A-75101-09:1990 | PB-PAZ/FS-32 wersja 01 z dnia 22.02.2021 r.","technique_en":"Distillation-oscillation method","test_object_en":"Fruit, vegetable and fruit-vegetable products, juices, nectars, syrups, beverage bases","parameters_zh":[{"name":"范围","range":"(0,05 - 3,5) %"}],"search_zh":"乙醇含量 蒸馏-振荡法 范围 PN-A-75101-09:1990 | PB-PAZ/FS-32 wersja 01 z dnia 22.02.2021 r.","methodology_zh":"乙醇含量","technique_zh":"蒸馏-振荡法"},{"_id":"6a8369ecaf14b9c0e7b1dd10","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Soki","methodology":"Liczba formolowa","parameters":[{"name":"Zakres","range":"(2 - 30) ml 0,1 mol/l NaOH/100 ml"}],"technique":"Metoda miareczkowania potencjometrycznego","techniques":["Metoda miareczkowania potencjometrycznego"],"computed":[],"activity":"Liczba formolowa\nZakres (2 - 30) ml 0,1 mol/l NaOH/100 ml\nMetoda miareczkowania potencjometrycznego","reference":"PN-EN 1133:1999","norm_bases":["PN-EN 1133:1999"],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Soki Liczba formolowa\nZakres (2 - 30) ml 0,1 mol/l NaOH/100 ml\nMetoda miareczkowania potencjometrycznego PN-EN 1133:1999 Soki Liczba formolowa\nZakres (2 - 30) ml 0,1 mol/l NaOH/100 ml\nMetoda miareczkowania potencjometrycznego PN-EN 1133:1999","categories":["other"],"row_index":238,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Formol number","parameters_en":[{"name":"Range","range":"(2 - 30) ml 0,1 mol/l NaOH/100 ml"}],"search_en":"Juices Formol number Potentiometric titration method Range PN-EN 1133:1999","technique_en":"Potentiometric titration method","test_object_en":"Juices","parameters_zh":[{"name":"范围","range":"(2 - 30) ml 0,1 mol/l NaOH/100 ml"}],"search_zh":"果汁 甲醛值 电位滴定法 范围 PN-EN 1133:1999","technique_zh":"电位滴定法","test_object_zh":"果汁","methodology_zh":"甲醛值"},{"_id":"6a8369ecaf14b9c0e7b1dd11","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Ryby i przetwory rybne, Owoce morza","methodology":"Zawartość glazury","parameters":[{"name":"Zakres","range":"(5 - 45) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość glazury\nZakres (5 - 45) %\nMetoda wagowa","reference":"PB-PAZ/FS-21 wersja 01 z dnia 22.02.2021 r.","norm_bases":["PB-PAZ/FS-21 wersja 01 z dnia 22.02.2021 r."],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ryby i przetwory rybne, Owoce morza Zawartość glazury\nZakres (5 - 45) %\nMetoda wagowa PB-PAZ/FS-21 wersja 01 z dnia 22.02.2021 r. Ryby i przetwory rybne, Owoce morza Zawartosc glazury\nZakres (5 - 45) %\nMetoda wagowa PB-PAZ/FS-21 wersja 01 z dnia 22.02.2021 r.","categories":["other"],"row_index":239,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Glaze content","parameters_en":[{"name":"Range","range":"(5 - 45) %"}],"search_en":"Fish and fish products, Seafood Glaze content Gravimetric method Range PB-PAZ/FS-21 wersja 01 z dnia 22.02.2021 r.","technique_en":"Gravimetric method","test_object_en":"Fish and fish products, Seafood","parameters_zh":[{"name":"范围","range":"(5 - 45) %"}],"search_zh":"冰衣含量 重量法 范围 PB-PAZ/FS-21 wersja 01 z dnia 22.02.2021 r.","technique_zh":"重量法","methodology_zh":"冰衣含量"},{"_id":"6a8369ecaf14b9c0e7b1dd12","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Zboża i przetwory zbożowe, słodycze, wyroby cukiernicze i ciastkarskie, mleko i produkty mleczne, tłuszcze zwierzęce, przetwory owocowe, warzywne, owocowo- warzywne i warzywno-mięsne, mięso i produkty mięsne, ryby i przetwory rybne oraz owoce morza, wyroby garmażeryjne, koncentraty spożywcze, przyprawy, nasiona roślin strączkowych, jaja i ich przetwory, warzywa, owoce, zioła, nasiona oleiste, oleje, tłuszcze roślinne i zwierzęce, herbata, napoje bezalkoholowe, majonez, musztarda, sosy i dresingi, pieczywo, półprodukty i wyroby piekarnicze, bakalie i orzechy, produkty ziemniaczane i zbożowe, suplementy diety, Pasze","methodology":"Oznaczanie zawartości tłuszczu","parameters":[{"name":"Zakres","range":"(0,20 – 100,00) %"}],"technique":"Metoda spektrometrii magnetycznego rezonansu jądrowego (NMR)","techniques":["Metoda spektrometrii magnetycznego rezonansu jądrowego (NMR)"],"computed":[],"activity":"Oznaczanie zawartości tłuszczu\nZakres (0,20 – 100,00) %\nMetoda spektrometrii magnetycznego rezonansu jądrowego (NMR)","reference":"PB-PAZ/FS-40 wersja 01 z dnia 24.02.2023 r.","norm_bases":["PB-PAZ/FS-40 wersja 01 z dnia 24.02.2023 r."],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Zboża i przetwory zbożowe, słodycze, wyroby cukiernicze i ciastkarskie, mleko i produkty mleczne, tłuszcze zwierzęce, przetwory owocowe, warzywne, owocowo- warzywne i warzywno-mięsne, mięso i produkty mięsne, ryby i przetwory rybne oraz owoce morza, wyroby garmażeryjne, koncentraty spożywcze, przyprawy, nasiona roślin strączkowych, jaja i ich przetwory, warzywa, owoce, zioła, nasiona oleiste, oleje, tłuszcze roślinne i zwierzęce, herbata, napoje bezalkoholowe, majonez, musztarda, sosy i dresingi, pieczywo, półprodukty i wyroby piekarnicze, bakalie i orzechy, produkty ziemniaczane i zbożowe, suplementy diety, Pasze Oznaczanie zawartości tłuszczu\nZakres (0,20 – 100,00) %\nMetoda spektrometrii magnetycznego rezonansu jądrowego (NMR) PB-PAZ/FS-40 wersja 01 z dnia 24.02.2023 r. Zboza i przetwory zbozowe, slodycze, wyroby cukiernicze i ciastkarskie, mleko i produkty mleczne, tluszcze zwierzece, przetwory owocowe, warzywne, owocowo- warzywne i warzywno-miesne, mieso i produkty miesne, ryby i przetwory rybne oraz owoce morza, wyroby garmazeryjne, koncentraty spozywcze, przyprawy, nasiona roslin straczkowych, jaja i ich przetwory, warzywa, owoce, ziola, nasiona oleiste, oleje, tluszcze roslinne i zwierzece, herbata, napoje bezalkoholowe, majonez, musztarda, sosy i dresingi, pieczywo, polprodukty i wyroby piekarnicze, bakalie i orzechy, produkty ziemniaczane i zbozowe, suplementy diety, Pasze Oznaczanie zawartosci tluszczu\nZakres (0,20 – 100,00) %\nMetoda spektrometrii magnetycznego rezonansu jadrowego (NMR) PB-PAZ/FS-40 wersja 01 z dnia 24.02.2023 r.","categories":["food","petro","pharma"],"row_index":240,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Determination of fat content","parameters_en":[{"name":"Range","range":"(0,20 – 100,00) %"}],"search_en":"Cereals and cereal products, sweets, confectionery and pastry products, milk and milk products, animal fats, fruit, vegetable, fruit-vegetable and vegetable-meat preserves, meat and meat products, fish and fish products and seafood, delicatessen products, food concentrates, spices, legume seeds, eggs and egg products, vegetables, fruits, herbs, oilseeds, oils, vegetable and animal fats, tea, non-alcoholic beverages, mayonnaise, mustard, sauces and dressings, bread, semi-finished and bakery products, dried fruits and nuts, potato and cereal products, dietary supplements, Feed Determination of fat content Nuclear magnetic resonance spectrometry method (NMR) Range PB-PAZ/FS-40 wersja 01 z dnia 24.02.2023 r.","technique_en":"Nuclear magnetic resonance spectrometry method (NMR)","test_object_en":"Cereals and cereal products, sweets, confectionery and pastry products, milk and milk products, animal fats, fruit, vegetable, fruit-vegetable and vegetable-meat preserves, meat and meat products, fish and fish products and seafood, delicatessen products, food concentrates, spices, legume seeds, eggs and egg products, vegetables, fruits, herbs, oilseeds, oils, vegetable and animal fats, tea, non-alcoholic beverages, mayonnaise, mustard, sauces and dressings, bread, semi-finished and bakery products, dried fruits and nuts, potato and cereal products, dietary supplements, Feed","parameters_zh":[{"name":"范围","range":"(0,20 – 100,00) %"}],"search_zh":"范围 PB-PAZ/FS-40 wersja 01 z dnia 24.02.2023 r."},{"_id":"6a8369ecaf14b9c0e7b1dd13","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Przetwory owocowe, warzywne, owocowo-warzywne (płynne i półpłynne), napoje bezalkoholowe, syropy, zaprawy, mleko i produkty mleczne (płynne i półpłynne), oleje i tłuszcze, napoje alkoholowe, majonez, Wyroby chemiczne i kosmetyczne (płynne i półpłynne)","methodology":"Gęstość","parameters":[{"name":"Zakres","range":"(0,92 - 1,5) g/cm3"}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"computed":[],"activity":"Gęstość\nZakres (0,92 - 1,5) g/cm3\nMetoda oscylacyjna","reference":"PB-PAZ/FS-16 wersja 02 z dnia 10.03.2022 r.","norm_bases":["PB-PAZ/FS-16 wersja 02 z dnia 10.03.2022 r."],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przetwory owocowe, warzywne, owocowo-warzywne (płynne i półpłynne), napoje bezalkoholowe, syropy, zaprawy, mleko i produkty mleczne (płynne i półpłynne), oleje i tłuszcze, napoje alkoholowe, majonez, Wyroby chemiczne i kosmetyczne (płynne i półpłynne) Gęstość\nZakres (0,92 - 1,5) g/cm3\nMetoda oscylacyjna PB-PAZ/FS-16 wersja 02 z dnia 10.03.2022 r. Przetwory owocowe, warzywne, owocowo-warzywne (plynne i polplynne), napoje bezalkoholowe, syropy, zaprawy, mleko i produkty mleczne (plynne i polplynne), oleje i tluszcze, napoje alkoholowe, majonez, Wyroby chemiczne i kosmetyczne (plynne i polplynne) Gestosc\nZakres (0,92 - 1,5) g/cm3\nMetoda oscylacyjna PB-PAZ/FS-16 wersja 02 z dnia 10.03.2022 r.","categories":["food","petro"],"row_index":241,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Density","parameters_en":[{"name":"Range","range":"(0,92 - 1,5) g/cm3"}],"search_en":"Fruit, vegetable and fruit-vegetable products (liquid and semi-liquid), non-alcoholic beverages, syrups, cordials, milk and milk products (liquid and semi-liquid), oils and fats, alcoholic beverages, mayonnaise, Chemical and cosmetic products (liquid and semi-liquid) Density Oscillation method Range PB-PAZ/FS-16 wersja 02 z dnia 10.03.2022 r.","technique_en":"Oscillation method","test_object_en":"Fruit, vegetable and fruit-vegetable products (liquid and semi-liquid), non-alcoholic beverages, syrups, cordials, milk and milk products (liquid and semi-liquid), oils and fats, alcoholic beverages, mayonnaise, Chemical and cosmetic products (liquid and semi-liquid)","methodology_zh":"密度","parameters_zh":[{"name":"范围","range":"(0,92 - 1,5) g/cm3"}],"search_zh":"密度 振荡法 范围 PB-PAZ/FS-16 wersja 02 z dnia 10.03.2022 r.","technique_zh":"振荡法"},{"_id":"6a8369ecaf14b9c0e7b1dd14","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Napoje alkoholowe, napoje bezalkoholowe (soki, nektary, zaprawy), owoce, przetwory warzywne, owocowo-warzywne, owocowe, bakalie, koncentraty spożywcze, ocet, grzyby i przetwory, wyroby garmażeryjne","methodology":"Zawartość całkowitego SO2","parameters":[{"name":"Zakres","range":"(10 - 1000) mg/kg"},{"name":"Zakres","range":"(10 - 1000) mg/l"}],"technique":"Metoda destylacyjno-miareczkowa","techniques":["Metoda destylacyjno-miareczkowa"],"computed":[],"activity":"Zawartość całkowitego SO2\nZakres:\nZakres (10 - 1000) mg/kg\nZakres (10 - 1000) mg/l\nMetoda destylacyjno-miareczkowa","reference":"PB-PAZ/FS-27 wersja 01 z dnia 22.02.2021 r.","norm_bases":["PB-PAZ/FS-27 wersja 01 z dnia 22.02.2021 r."],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Napoje alkoholowe, napoje bezalkoholowe (soki, nektary, zaprawy), owoce, przetwory warzywne, owocowo-warzywne, owocowe, bakalie, koncentraty spożywcze, ocet, grzyby i przetwory, wyroby garmażeryjne Zawartość całkowitego SO2\nZakres:\nZakres (10 - 1000) mg/kg\nZakres (10 - 1000) mg/l\nMetoda destylacyjno-miareczkowa PB-PAZ/FS-27 wersja 01 z dnia 22.02.2021 r. Napoje alkoholowe, napoje bezalkoholowe (soki, nektary, zaprawy), owoce, przetwory warzywne, owocowo-warzywne, owocowe, bakalie, koncentraty spozywcze, ocet, grzyby i przetwory, wyroby garmazeryjne Zawartosc calkowitego SO2\nZakres:\nZakres (10 - 1000) mg/kg\nZakres (10 - 1000) mg/l\nMetoda destylacyjno-miareczkowa PB-PAZ/FS-27 wersja 01 z dnia 22.02.2021 r.","categories":["food","microbiology"],"row_index":242,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total SO2 content","parameters_en":[{"name":"Range","range":"(10 - 1000) mg/kg"},{"name":"Range","range":"(10 - 1000) mg/l"}],"search_en":"Alcoholic beverages, non-alcoholic beverages (juices, nectars, beverage bases), fruit, vegetable, fruit-vegetable and fruit products, dried fruit and nuts, food concentrates, vinegar, mushrooms and mushroom products, delicatessen products Total SO2 content Distillation-titrimetric method Range Range PB-PAZ/FS-27 wersja 01 z dnia 22.02.2021 r.","technique_en":"Distillation-titrimetric method","test_object_en":"Alcoholic beverages, non-alcoholic beverages (juices, nectars, beverage bases), fruit, vegetable, fruit-vegetable and fruit products, dried fruit and nuts, food concentrates, vinegar, mushrooms and mushroom products, delicatessen products","parameters_zh":[{"name":"范围","range":"(10 - 1000) mg/kg"},{"name":"范围","range":"(10 - 1000) mg/l"}],"search_zh":"蒸馏-滴定法 范围 范围 PB-PAZ/FS-27 wersja 01 z dnia 22.02.2021 r.","technique_zh":"蒸馏-滴定法"},{"_id":"6a8369ecaf14b9c0e7b1dd15","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Napoje alkoholowe - wyroby spirytusowe - drinki alkoholowe","methodology":"Zawartość alkoholu etylowego (moc)","parameters":[{"name":"Zakres","range":"(4 - 96) % obj."}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"computed":[],"activity":"Zawartość alkoholu etylowego (moc)\nZakres (4 - 96) % obj.\nMetoda oscylacyjna","reference":"Rozporządzenie Komisji (WE) Nr 2870/2000, załącznik nr I (Dz. U. L 333 z 29.12.2000 r.)","norm_bases":["Rozporządzenie Komisji (WE) Nr 2870/2000, załącznik nr I (Dz. U. L 333 z 29.12.2000 r.)"],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Napoje alkoholowe - wyroby spirytusowe - drinki alkoholowe Zawartość alkoholu etylowego (moc)\nZakres (4 - 96) % obj.\nMetoda oscylacyjna Rozporządzenie Komisji (WE) Nr 2870/2000, załącznik nr I (Dz. U. L 333 z 29.12.2000 r.) Napoje alkoholowe - wyroby spirytusowe - drinki alkoholowe Zawartosc alkoholu etylowego (moc)\nZakres (4 - 96) % obj.\nMetoda oscylacyjna Rozporzadzenie Komisji (WE) Nr 2870/2000, zalacznik nr I (Dz. U. L 333 z 29.12.2000 r.)","categories":["food"],"row_index":243,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ethyl alcohol content (strength)","parameters_en":[{"name":"Range","range":"(4 - 96) % obj."}],"search_en":"Alcoholic beverages - spirit drinks - alcoholic mixed drinks Ethyl alcohol content (strength) Oscillation method Range Rozporządzenie Komisji (WE) Nr 2870/2000, załącznik nr I (Dz. U. L 333 z 29.12.2000 r.)","technique_en":"Oscillation method","test_object_en":"Alcoholic beverages - spirit drinks - alcoholic mixed drinks","parameters_zh":[{"name":"范围","range":"(4 - 96) % obj."}],"search_zh":"振荡法 范围 Rozporządzenie Komisji (WE) Nr 2870/2000, załącznik nr I (Dz. U. L 333 z 29.12.2000 r.)","technique_zh":"振荡法"},{"_id":"6a8369ecaf14b9c0e7b1dd16","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Wina i wyroby winiarskie","methodology":"Zawartość alkoholu etylowego","parameters":[{"name":"Zakres","range":"(4 - 14) % obj."}],"technique":"Metoda destylacyjno-oscylacyjna","techniques":["Metoda destylacyjno-oscylacyjna"],"computed":[],"activity":"Zawartość alkoholu etylowego\nZakres (4 - 14) % obj.\nMetoda destylacyjno-oscylacyjna","reference":"PB-PAZ/FS-37 wersja 01 z dnia 10.03.2022 r.","norm_bases":["PB-PAZ/FS-37 wersja 01 z dnia 10.03.2022 r."],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wina i wyroby winiarskie Zawartość alkoholu etylowego\nZakres (4 - 14) % obj.\nMetoda destylacyjno-oscylacyjna PB-PAZ/FS-37 wersja 01 z dnia 10.03.2022 r. Wina i wyroby winiarskie Zawartosc alkoholu etylowego\nZakres (4 - 14) % obj.\nMetoda destylacyjno-oscylacyjna PB-PAZ/FS-37 wersja 01 z dnia 10.03.2022 r.","categories":["other"],"row_index":244,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ethyl alcohol content","parameters_en":[{"name":"Range","range":"(4 - 14) % obj."}],"search_en":"Wines and wine products Ethyl alcohol content Distillation-oscillation method Range PB-PAZ/FS-37 wersja 01 z dnia 10.03.2022 r.","technique_en":"Distillation-oscillation method","test_object_en":"Wines and wine products","parameters_zh":[{"name":"范围","range":"(4 - 14) % obj."}],"search_zh":"乙醇含量 蒸馏-振荡法 范围 PB-PAZ/FS-37 wersja 01 z dnia 10.03.2022 r.","methodology_zh":"乙醇含量","technique_zh":"蒸馏-振荡法"},{"_id":"6a8369ecaf14b9c0e7b1dd17","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Piwo","methodology":"Zawartość alkoholu etylowego","parameters":[{"name":"Zakres","range":"(0,5 - 10) % (v/v)"}],"technique":"Metoda destylacyjno-oscylacyjna","techniques":["Metoda destylacyjno-oscylacyjna"],"computed":[],"activity":"Zawartość alkoholu etylowego\nZakres (0,5 - 10) % (v/v)\nMetoda destylacyjno-oscylacyjna","reference":"PN-A-79093-2:2000+Ap1:2002 z wyłączeniem pkt. 2.1.3.2 i pkt. 2.2 | PB-PAZ/FS-31 wersja 01 z dnia 22.02.2021 r.","norm_bases":["PN-A-79093-2:2000+Ap1:2002 z wyłączeniem pkt. 2.1.3.2 i pkt. 2.2","PB-PAZ/FS-31 wersja 01 z dnia 22.02.2021 r."],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Piwo Zawartość alkoholu etylowego\nZakres (0,5 - 10) % (v/v)\nMetoda destylacyjno-oscylacyjna PN-A-79093-2:2000+Ap1:2002 z wyłączeniem pkt. 2.1.3.2 i pkt. 2.2 | PB-PAZ/FS-31 wersja 01 z dnia 22.02.2021 r. Piwo Zawartosc alkoholu etylowego\nZakres (0,5 - 10) % (v/v)\nMetoda destylacyjno-oscylacyjna PN-A-79093-2:2000+Ap1:2002 z wylaczeniem pkt. 2.1.3.2 i pkt. 2.2 | PB-PAZ/FS-31 wersja 01 z dnia 22.02.2021 r.","categories":["other"],"row_index":245,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ethyl alcohol content","parameters_en":[{"name":"Range","range":"(0,5 - 10) % (v/v)"}],"search_en":"Beer Ethyl alcohol content Distillation-oscillation method Range PN-A-79093-2:2000+Ap1:2002 z wyłączeniem pkt. 2.1.3.2 i pkt. 2.2 | PB-PAZ/FS-31 wersja 01 z dnia 22.02.2021 r.","technique_en":"Distillation-oscillation method","test_object_en":"Beer","parameters_zh":[{"name":"范围","range":"(0,5 - 10) % (v/v)"}],"search_zh":"啤酒 乙醇含量 蒸馏-振荡法 范围 PN-A-79093-2:2000+Ap1:2002 z wyłączeniem pkt. 2.1.3.2 i pkt. 2.2 | PB-PAZ/FS-31 wersja 01 z dnia 22.02.2021 r.","test_object_zh":"啤酒","methodology_zh":"乙醇含量","technique_zh":"蒸馏-振荡法"},{"_id":"6a8369ecaf14b9c0e7b1dd18","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Mięso i przetwory mięsne","methodology":"Stosunek kolagenu do białka (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stosunek kolagenu do białka (z obliczeń)","reference":"Rozporządzenie Parlamentu Europejskiego i Rady (UE) Nr 1169/2011 z dnia 25 października 2011 r., (Dz. U. L 304 z 22.11.2011)","norm_bases":["Rozporządzenie Parlamentu Europejskiego i Rady (UE) Nr 1169/2011 z dnia 25 października 2011 r., (Dz. U. L 304 z 22.11.2011)"],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i przetwory mięsne Stosunek kolagenu do białka (z obliczeń) Rozporządzenie Parlamentu Europejskiego i Rady (UE) Nr 1169/2011 z dnia 25 października 2011 r., (Dz. U. L 304 z 22.11.2011) Mieso i przetwory miesne Stosunek kolagenu do bialka (z obliczen) Rozporzadzenie Parlamentu Europejskiego i Rady (UE) Nr 1169/2011 z dnia 25 pazdziernika 2011 r., (Dz. U. L 304 z 22.11.2011)","categories":["food"],"row_index":246,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Collagen to protein ratio (calculated)","search_en":"Meat and meat products Collagen to protein ratio (calculated) Rozporządzenie Parlamentu Europejskiego i Rady (UE) Nr 1169/2011 z dnia 25 października 2011 r., (Dz. U. L 304 z 22.11.2011)","test_object_en":"Meat and meat products","search_zh":"肉与肉制品 Rozporządzenie Parlamentu Europejskiego i Rady (UE) Nr 1169/2011 z dnia 25 października 2011 r., (Dz. U. L 304 z 22.11.2011)","test_object_zh":"肉与肉制品"},{"_id":"6a8369ecaf14b9c0e7b1dd19","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Mięso i przetwory mięsne","methodology":"Zawartość fosforu całkowitego","parameters":[{"name":"Zakres","range":"(0,07 - 5,5) % P2O5"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość fosforu całkowitego\nZakres (0,07 - 5,5) % P2O5\nMetoda wagowa","reference":"PN-A-82060:1999","norm_bases":["PN-A-82060:1999"],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i przetwory mięsne Zawartość fosforu całkowitego\nZakres (0,07 - 5,5) % P2O5\nMetoda wagowa PN-A-82060:1999 Mieso i przetwory miesne Zawartosc fosforu calkowitego\nZakres (0,07 - 5,5) % P2O5\nMetoda wagowa PN-A-82060:1999","categories":["food"],"row_index":247,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total phosphorus content","parameters_en":[{"name":"Range","range":"(0,07 - 5,5) % P2O5"}],"search_en":"Meat and meat products Total phosphorus content Gravimetric method Range PN-A-82060:1999","technique_en":"Gravimetric method","test_object_en":"Meat and meat products","parameters_zh":[{"name":"范围","range":"(0,07 - 5,5) % P2O5"}],"search_zh":"肉与肉制品 总磷含量 重量法 范围 PN-A-82060:1999","technique_zh":"重量法","test_object_zh":"肉与肉制品","methodology_zh":"总磷含量"},{"_id":"6a8369ecaf14b9c0e7b1dd1a","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Mięso i przetwory mięsne","methodology":"Zawartość fosforu dodanego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość fosforu dodanego (z obliczeń)","reference":"PN-A-82060:1999","norm_bases":["PN-A-82060:1999"],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i przetwory mięsne Zawartość fosforu dodanego (z obliczeń) PN-A-82060:1999 Mieso i przetwory miesne Zawartosc fosforu dodanego (z obliczen) PN-A-82060:1999","categories":["food"],"row_index":248,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Added phosphorus content (calculated)","search_en":"Meat and meat products Added phosphorus content (calculated) PN-A-82060:1999","test_object_en":"Meat and meat products","search_zh":"肉与肉制品 添加磷含量（由计算得出） PN-A-82060:1999","test_object_zh":"肉与肉制品","methodology_zh":"添加磷含量（由计算得出）"},{"_id":"6a8369ecaf14b9c0e7b1dd1b","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Oleje i tłuszcze roślinne i zwierzęce","methodology":"Kwasowość tłuszczu","parameters":[{"name":"Zakres","range":"(0,1 - 40,0) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Kwasowość tłuszczu\nZakres (0,1 - 40,0) %\nMetoda miareczkowa","reference":"PB-PAZ/FS-25 wersja 01 z dnia 22.02.2021 r.","norm_bases":["PB-PAZ/FS-25 wersja 01 z dnia 22.02.2021 r."],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Oleje i tłuszcze roślinne i zwierzęce Kwasowość tłuszczu\nZakres (0,1 - 40,0) %\nMetoda miareczkowa PB-PAZ/FS-25 wersja 01 z dnia 22.02.2021 r. Oleje i tluszcze roslinne i zwierzece Kwasowosc tluszczu\nZakres (0,1 - 40,0) %\nMetoda miareczkowa PB-PAZ/FS-25 wersja 01 z dnia 22.02.2021 r.","categories":["food","petro"],"row_index":249,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Acidity of fat","parameters_en":[{"name":"Range","range":"(0,1 - 40,0) %"}],"search_en":"Vegetable and animal oils and fats Acidity of fat Titrimetric method Range PB-PAZ/FS-25 wersja 01 z dnia 22.02.2021 r.","technique_en":"Titrimetric method","test_object_en":"Vegetable and animal oils and fats","parameters_zh":[{"name":"范围","range":"(0,1 - 40,0) %"}],"search_zh":"植物油脂与动物油脂 脂肪酸度 滴定法 范围 PB-PAZ/FS-25 wersja 01 z dnia 22.02.2021 r.","technique_zh":"滴定法","test_object_zh":"植物油脂与动物油脂","methodology_zh":"脂肪酸度"},{"_id":"6a8369ecaf14b9c0e7b1dd1c","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Oleje i tłuszcze roślinne i zwierzęce, sosy, bakalie, produkty i półprodukty ziemniaczane, pszenne i kukurydziane, wyroby kulinarne, pasze, wyroby cukiernicze","methodology":"Kwasowość (Wolne kwasy tłuszczowe)","parameters":[{"name":"Zakres","range":"(0,1 - 60) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Kwasowość (Wolne kwasy tłuszczowe)\nZakres (0,1 - 60) %\nMetoda miareczkowa","reference":"PB-PAZ/FS-25 wersja 01 z dnia 22.02.2021 r.","norm_bases":["PB-PAZ/FS-25 wersja 01 z dnia 22.02.2021 r."],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Oleje i tłuszcze roślinne i zwierzęce, sosy, bakalie, produkty i półprodukty ziemniaczane, pszenne i kukurydziane, wyroby kulinarne, pasze, wyroby cukiernicze Kwasowość (Wolne kwasy tłuszczowe)\nZakres (0,1 - 60) %\nMetoda miareczkowa PB-PAZ/FS-25 wersja 01 z dnia 22.02.2021 r. Oleje i tluszcze roslinne i zwierzece, sosy, bakalie, produkty i polprodukty ziemniaczane, pszenne i kukurydziane, wyroby kulinarne, pasze, wyroby cukiernicze Kwasowosc (Wolne kwasy tluszczowe)\nZakres (0,1 - 60) %\nMetoda miareczkowa PB-PAZ/FS-25 wersja 01 z dnia 22.02.2021 r.","categories":["food","petro"],"row_index":250,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Acidity (Free fatty acids)","parameters_en":[{"name":"Range","range":"(0,1 - 60) %"}],"search_en":"Vegetable and animal oils and fats, sauces, dried fruit and nuts, potato, wheat and maize products and semi-finished products, culinary products, feed, confectionery products Acidity (Free fatty acids) Titrimetric method Range PB-PAZ/FS-25 wersja 01 z dnia 22.02.2021 r.","technique_en":"Titrimetric method","test_object_en":"Vegetable and animal oils and fats, sauces, dried fruit and nuts, potato, wheat and maize products and semi-finished products, culinary products, feed, confectionery products","parameters_zh":[{"name":"范围","range":"(0,1 - 60) %"}],"search_zh":"滴定法 范围 PB-PAZ/FS-25 wersja 01 z dnia 22.02.2021 r.","technique_zh":"滴定法"},{"_id":"6a8369ecaf14b9c0e7b1dd1d","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Pieczywo i półprodukty piekarnicze, przetwory zbożowe","methodology":"Kwasowość","parameters":[{"name":"Zakres","range":"(1 - 20) °"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Kwasowość\nZakres (1 - 20) °\nMetoda miareczkowa","reference":"PB-PAZ/FS-28 wersja 01 z dnia 22.02.2021 r.","norm_bases":["PB-PAZ/FS-28 wersja 01 z dnia 22.02.2021 r."],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pieczywo i półprodukty piekarnicze, przetwory zbożowe Kwasowość\nZakres (1 - 20) °\nMetoda miareczkowa PB-PAZ/FS-28 wersja 01 z dnia 22.02.2021 r. Pieczywo i polprodukty piekarnicze, przetwory zbozowe Kwasowosc\nZakres (1 - 20) °\nMetoda miareczkowa PB-PAZ/FS-28 wersja 01 z dnia 22.02.2021 r.","categories":["other"],"row_index":251,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Acidity","parameters_en":[{"name":"Range","range":"(1 - 20) °"}],"search_en":"Bread and bakery semi-products, cereal products Acidity Titrimetric method Range PB-PAZ/FS-28 wersja 01 z dnia 22.02.2021 r.","technique_en":"Titrimetric method","test_object_en":"Bread and bakery semi-products, cereal products","methodology_zh":"酸度","parameters_zh":[{"name":"范围","range":"(1 - 20) °"}],"search_zh":"酸度 滴定法 范围 PB-PAZ/FS-28 wersja 01 z dnia 22.02.2021 r.","technique_zh":"滴定法"},{"_id":"6a8369ecaf14b9c0e7b1dd1e","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Wyroby i półprodukty cukiernicze","methodology":"Kwasowość ogólna","parameters":[{"name":"Zakres","range":"(0,2 - 45) °N"},{"name":"Kwasowość w przeliczeniu na procenty jednowodnego kwasu cytrynowego (z obliczeń)"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Kwasowość ogólna\nZakres:\nZakres (0,2 - 45) °N\nKwasowość w przeliczeniu na procenty jednowodnego kwasu cytrynowego (z obliczeń)\nMetoda miareczkowa","reference":"PB-PAZ/FS-28 wersja 01 z dnia 22.02.2021 r.","norm_bases":["PB-PAZ/FS-28 wersja 01 z dnia 22.02.2021 r."],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby i półprodukty cukiernicze Kwasowość ogólna\nZakres:\nZakres (0,2 - 45) °N\nKwasowość w przeliczeniu na procenty jednowodnego kwasu cytrynowego (z obliczeń)\nMetoda miareczkowa PB-PAZ/FS-28 wersja 01 z dnia 22.02.2021 r. Wyroby i polprodukty cukiernicze Kwasowosc ogolna\nZakres:\nZakres (0,2 - 45) °N\nKwasowosc w przeliczeniu na procenty jednowodnego kwasu cytrynowego (z obliczen)\nMetoda miareczkowa PB-PAZ/FS-28 wersja 01 z dnia 22.02.2021 r.","categories":["food"],"row_index":252,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total acidity","parameters_en":[{"name":"Range","range":"(0,2 - 45) °N"},{"name":"Acidity expressed as percentage of citric acid monohydrate (calculated)"}],"search_en":"Confectionery products and semi-finished products Total acidity Titrimetric method Range Acidity expressed as percentage of citric acid monohydrate (calculated) PB-PAZ/FS-28 wersja 01 z dnia 22.02.2021 r.","technique_en":"Titrimetric method","test_object_en":"Confectionery products and semi-finished products","parameters_zh":[{"name":"范围","range":"(0,2 - 45) °N"},{"name":"Kwasowość w przeliczeniu na procenty jednowodnego kwasu cytrynowego (z obliczeń)"}],"search_zh":"糖果制品与半成品 总酸度 滴定法 范围 PB-PAZ/FS-28 wersja 01 z dnia 22.02.2021 r.","technique_zh":"滴定法","methodology_zh":"总酸度","test_object_zh":"糖果制品与半成品"},{"_id":"6a8369ecaf14b9c0e7b1dd1f","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Oleje i tłuszcze roślinne i zwierzęce, suplementy diety (na bazie oleju)","methodology":"Liczba anizydynowa","parameters":[{"name":"Zakres","range":"0,1 - 280"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Liczba anizydynowa\nZakres 0,1 - 280\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6885:2016-04","norm_bases":["PN-EN ISO 6885:2016-04"],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Oleje i tłuszcze roślinne i zwierzęce, suplementy diety (na bazie oleju) Liczba anizydynowa\nZakres 0,1 - 280\nMetoda spektrofotometryczna PN-EN ISO 6885:2016-04 Oleje i tluszcze roslinne i zwierzece, suplementy diety (na bazie oleju) Liczba anizydynowa\nZakres 0,1 - 280\nMetoda spektrofotometryczna PN-EN ISO 6885:2016-04","categories":["food","petro","pharma"],"row_index":253,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Anisidine value","parameters_en":[{"name":"Range","range":"0,1 - 280"}],"search_en":"Vegetable and animal oils and fats, food supplements (oil-based) Anisidine value Spectrophotometric method Range PN-EN ISO 6885:2016-04","technique_en":"Spectrophotometric method","test_object_en":"Vegetable and animal oils and fats, food supplements (oil-based)","parameters_zh":[{"name":"范围","range":"0,1 - 280"}],"search_zh":"茴香胺值 分光光度法 范围 PN-EN ISO 6885:2016-04","technique_zh":"分光光度法","methodology_zh":"茴香胺值"},{"_id":"6a8369ecaf14b9c0e7b1dd20","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Oleje i tłuszcze roślinne i zwierzęce","methodology":"Liczba zmydlenia","parameters":[{"name":"Zakres","range":"(160 - 240) mg KOH/g"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Liczba zmydlenia\nZakres (160 - 240) mg KOH/g\nMetoda miareczkowa","reference":"PN-EN ISO 3657:2024-01","norm_bases":["PN-EN ISO 3657:2024-01"],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Oleje i tłuszcze roślinne i zwierzęce Liczba zmydlenia\nZakres (160 - 240) mg KOH/g\nMetoda miareczkowa PN-EN ISO 3657:2024-01 Oleje i tluszcze roslinne i zwierzece Liczba zmydlenia\nZakres (160 - 240) mg KOH/g\nMetoda miareczkowa PN-EN ISO 3657:2024-01","categories":["food","petro"],"row_index":254,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Saponification value","parameters_en":[{"name":"Range","range":"(160 - 240) mg KOH/g"}],"search_en":"Vegetable and animal oils and fats Saponification value Titrimetric method Range PN-EN ISO 3657:2024-01","technique_en":"Titrimetric method","test_object_en":"Vegetable and animal oils and fats","parameters_zh":[{"name":"范围","range":"(160 - 240) mg KOH/g"}],"search_zh":"植物油脂与动物油脂 皂化值 滴定法 范围 PN-EN ISO 3657:2024-01","technique_zh":"滴定法","test_object_zh":"植物油脂与动物油脂","methodology_zh":"皂化值"},{"_id":"6a8369ecaf14b9c0e7b1dd21","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Oleje i tłuszcze roślinne i zwierzęce","methodology":"Liczba jodowa","parameters":[{"name":"Zakres","range":"(6 - 180) g/100g"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Liczba jodowa\nZakres (6 - 180) g/100g\nMetoda miareczkowa","reference":"PN-EN ISO 3961:2018-09","norm_bases":["PN-EN ISO 3961:2018-09"],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Oleje i tłuszcze roślinne i zwierzęce Liczba jodowa\nZakres (6 - 180) g/100g\nMetoda miareczkowa PN-EN ISO 3961:2018-09 Oleje i tluszcze roslinne i zwierzece Liczba jodowa\nZakres (6 - 180) g/100g\nMetoda miareczkowa PN-EN ISO 3961:2018-09","categories":["food","petro"],"row_index":255,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Iodine value","parameters_en":[{"name":"Range","range":"(6 - 180) g/100g"}],"search_en":"Vegetable and animal oils and fats Iodine value Titrimetric method Range PN-EN ISO 3961:2018-09","technique_en":"Titrimetric method","test_object_en":"Vegetable and animal oils and fats","parameters_zh":[{"name":"范围","range":"(6 - 180) g/100g"}],"search_zh":"植物油脂与动物油脂 碘值 滴定法 范围 PN-EN ISO 3961:2018-09","technique_zh":"滴定法","test_object_zh":"植物油脂与动物油脂","methodology_zh":"碘值"},{"_id":"6a8369ecaf14b9c0e7b1dd22","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością","methodology":"Migracja specyficzna pierwiastków do 3 % kwasu octowego: − metoda przez całkowite zanurzenie − metoda z zastosowaniem torebki – metoda przez napełnienie wyrobu","parameters":[{"name":"Al","range":"(0,2 - 10,0) mg/kg"},{"name":"Sb","range":"(0,01 - 0,50) mg/kg"},{"name":"As","range":"(0,002 - 0,500) mg/kg"},{"name":"Ba","range":"(0,2 - 10,0) mg/kg"},{"name":"Cd","range":"(0,0004 - 0,5000) mg/kg"},{"name":"Ca","range":"(10 - 500) mg/kg"},{"name":"Cr","range":"(0,002 - 0,500) mg/kg"},{"name":"Co","range":"(0,01 - 0,50) mg/kg"},{"name":"Cu","range":"(0,5 - 25,0) mg/kg"},{"name":"Eu","range":"(0,01 - 0,50) mg/kg"},{"name":"Gd","range":"(0,01 - 0,50) mg/kg"},{"name":"Fe","range":"(0,5 - 100,0) mg/kg"},{"name":"La","range":"(0,01 - 0,50) mg/kg"},{"name":"Pb","range":"(0,002 - 0,500) mg/kg"},{"name":"Li","range":"(0,1 - 5,0) mg/kg"},{"name":"Mg","range":"(10 - 500) mg/kg"},{"name":"Mn","range":"(0,1 - 5,0) mg/kg"},{"name":"Hg","range":"(0,002 - 0,500) mg/kg"},{"name":"Ni","range":"(0,004 - 0,500) mg/kg"},{"name":"K","range":"(10 - 500) mg/kg"},{"name":"Na","range":"(10 - 500) mg/kg"},{"name":"Tb","range":"(0,01 - 0,50) mg/kg"},{"name":"Zn","range":"(0,5 - 25,0) mg/kg"}],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"computed":[],"activity":"Migracja specyficzna pierwiastków do 3 % kwasu octowego: − metoda przez całkowite zanurzenie − metoda z zastosowaniem torebki – metoda przez napełnienie wyrobu\nZakres:\nAl (0,2 - 10,0) mg/kg\nSb (0,01 - 0,50) mg/kg\nAs (0,002 - 0,500) mg/kg\nBa (0,2 - 10,0) mg/kg\nCd (0,0004 - 0,5000) mg/kg\nCa (10 - 500) mg/kg\nCr (0,002 - 0,500) mg/kg\nCo (0,01 - 0,50) mg/kg\nCu (0,5 - 25,0) mg/kg\nEu (0,01 - 0,50) mg/kg\nGd (0,01 - 0,50) mg/kg\nFe (0,5 - 100,0) mg/kg\nLa (0,01 - 0,50) mg/kg\nPb (0,002 - 0,500) mg/kg\nLi (0,1 - 5,0) mg/kg\nMg (10 - 500) mg/kg\nMn (0,1 - 5,0) mg/kg\nHg (0,002 - 0,500) mg/kg\nNi (0,004 - 0,500) mg/kg\nK (10 - 500) mg/kg\nNa (10 - 500) mg/kg\nTb (0,01 - 0,50) mg/kg\nZn (0,5 - 25,0) mg/kg\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"PB-PAZ/FS-45 wersja 02 z dnia 26.02.2026 r.","norm_bases":["PB-PAZ/FS-45 wersja 02 z dnia 26.02.2026 r."],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością Migracja specyficzna pierwiastków do 3 % kwasu octowego: − metoda przez całkowite zanurzenie − metoda z zastosowaniem torebki – metoda przez napełnienie wyrobu\nZakres:\nAl (0,2 - 10,0) mg/kg\nSb (0,01 - 0,50) mg/kg\nAs (0,002 - 0,500) mg/kg\nBa (0,2 - 10,0) mg/kg\nCd (0,0004 - 0,5000) mg/kg\nCa (10 - 500) mg/kg\nCr (0,002 - 0,500) mg/kg\nCo (0,01 - 0,50) mg/kg\nCu (0,5 - 25,0) mg/kg\nEu (0,01 - 0,50) mg/kg\nGd (0,01 - 0,50) mg/kg\nFe (0,5 - 100,0) mg/kg\nLa (0,01 - 0,50) mg/kg\nPb (0,002 - 0,500) mg/kg\nLi (0,1 - 5,0) mg/kg\nMg (10 - 500) mg/kg\nMn (0,1 - 5,0) mg/kg\nHg (0,002 - 0,500) mg/kg\nNi (0,004 - 0,500) mg/kg\nK (10 - 500) mg/kg\nNa (10 - 500) mg/kg\nTb (0,01 - 0,50) mg/kg\nZn (0,5 - 25,0) mg/kg\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) PB-PAZ/FS-45 wersja 02 z dnia 26.02.2026 r. Materialy i wyroby z tworzyw sztucznych przeznaczone do kontaktu z zywnoscia Migracja specyficzna pierwiastkow do 3 % kwasu octowego: − metoda przez calkowite zanurzenie − metoda z zastosowaniem torebki – metoda przez napelnienie wyrobu\nZakres:\nAl (0,2 - 10,0) mg/kg\nSb (0,01 - 0,50) mg/kg\nAs (0,002 - 0,500) mg/kg\nBa (0,2 - 10,0) mg/kg\nCd (0,0004 - 0,5000) mg/kg\nCa (10 - 500) mg/kg\nCr (0,002 - 0,500) mg/kg\nCo (0,01 - 0,50) mg/kg\nCu (0,5 - 25,0) mg/kg\nEu (0,01 - 0,50) mg/kg\nGd (0,01 - 0,50) mg/kg\nFe (0,5 - 100,0) mg/kg\nLa (0,01 - 0,50) mg/kg\nPb (0,002 - 0,500) mg/kg\nLi (0,1 - 5,0) mg/kg\nMg (10 - 500) mg/kg\nMn (0,1 - 5,0) mg/kg\nHg (0,002 - 0,500) mg/kg\nNi (0,004 - 0,500) mg/kg\nK (10 - 500) mg/kg\nNa (10 - 500) mg/kg\nTb (0,01 - 0,50) mg/kg\nZn (0,5 - 25,0) mg/kg\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) PB-PAZ/FS-45 wersja 02 z dnia 26.02.2026 r.","categories":["materials","food"],"row_index":256,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Specific migration of elements into 3 % acetic acid: − total immersion method − method using a pouch – article filling method","parameters_en":[{"name":"Al","range":"(0,2 - 10,0) mg/kg"},{"name":"Sb","range":"(0,01 - 0,50) mg/kg"},{"name":"As","range":"(0,002 - 0,500) mg/kg"},{"name":"Ba","range":"(0,2 - 10,0) mg/kg"},{"name":"Cd","range":"(0,0004 - 0,5000) mg/kg"},{"name":"Ca","range":"(10 - 500) mg/kg"},{"name":"Cr","range":"(0,002 - 0,500) mg/kg"},{"name":"Co","range":"(0,01 - 0,50) mg/kg"},{"name":"Cu","range":"(0,5 - 25,0) mg/kg"},{"name":"Eu","range":"(0,01 - 0,50) mg/kg"},{"name":"Gd","range":"(0,01 - 0,50) mg/kg"},{"name":"Fe","range":"(0,5 - 100,0) mg/kg"},{"name":"La","range":"(0,01 - 0,50) mg/kg"},{"name":"Pb","range":"(0,002 - 0,500) mg/kg"},{"name":"Li","range":"(0,1 - 5,0) mg/kg"},{"name":"Mg","range":"(10 - 500) mg/kg"},{"name":"Mn","range":"(0,1 - 5,0) mg/kg"},{"name":"Hg","range":"(0,002 - 0,500) mg/kg"},{"name":"Ni","range":"(0,004 - 0,500) mg/kg"},{"name":"K","range":"(10 - 500) mg/kg"},{"name":"Na","range":"(10 - 500) mg/kg"},{"name":"Tb","range":"(0,01 - 0,50) mg/kg"},{"name":"Zn","range":"(0,5 - 25,0) mg/kg"}],"search_en":"Plastic materials and articles intended to come into contact with food Specific migration of elements into 3 % acetic acid: − total immersion method − method using a pouch – article filling method Inductively coupled plasma mass spectrometry (ICP-MS) Al Sb As Ba Cd Ca Cr Co Cu Eu Gd Fe La Pb Li Mg Mn Hg Ni K Na Tb Zn PB-PAZ/FS-45 wersja 02 z dnia 26.02.2026 r.","technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","test_object_en":"Plastic materials and articles intended to come into contact with food","parameters_zh":[{"name":"Al","range":"(0,2 - 10,0) mg/kg"},{"name":"Sb","range":"(0,01 - 0,50) mg/kg"},{"name":"As","range":"(0,002 - 0,500) mg/kg"},{"name":"Ba","range":"(0,2 - 10,0) mg/kg"},{"name":"Cd","range":"(0,0004 - 0,5000) mg/kg"},{"name":"Ca","range":"(10 - 500) mg/kg"},{"name":"Cr","range":"(0,002 - 0,500) mg/kg"},{"name":"Co","range":"(0,01 - 0,50) mg/kg"},{"name":"Cu","range":"(0,5 - 25,0) mg/kg"},{"name":"Eu","range":"(0,01 - 0,50) mg/kg"},{"name":"Gd","range":"(0,01 - 0,50) mg/kg"},{"name":"Fe","range":"(0,5 - 100,0) mg/kg"},{"name":"La","range":"(0,01 - 0,50) mg/kg"},{"name":"Pb","range":"(0,002 - 0,500) mg/kg"},{"name":"Li","range":"(0,1 - 5,0) mg/kg"},{"name":"Mg","range":"(10 - 500) mg/kg"},{"name":"Mn","range":"(0,1 - 5,0) mg/kg"},{"name":"Hg","range":"(0,002 - 0,500) mg/kg"},{"name":"Ni","range":"(0,004 - 0,500) mg/kg"},{"name":"K","range":"(10 - 500) mg/kg"},{"name":"Na","range":"(10 - 500) mg/kg"},{"name":"Tb","range":"(0,01 - 0,50) mg/kg"},{"name":"Zn","range":"(0,5 - 25,0) mg/kg"}],"search_zh":"拟与食品接触的塑料材料及制品 电感耦合等离子体质谱法（ICP-MS） Al Sb As Ba Cd Ca Cr Co Cu Fe Pb Mg Mn Ni K Na Zn PB-PAZ/FS-45 wersja 02 z dnia 26.02.2026 r.","technique_zh":"电感耦合等离子体质谱法（ICP-MS）","test_object_zh":"拟与食品接触的塑料材料及制品"},{"_id":"6a8369ecaf14b9c0e7b1dd23","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością","methodology":"Migracja globalna płynów","parameters":[{"name":"modelowych − metoda przez całkowite zanurzenie − metoda z zastosowaniem torebki – metoda przez napełnienie wyrobu"},{"name":"Płyny modelowe: woda kwas octowy 3 % etanol 10 % etanol 20 % etanol 50 %"},{"name":"Zakres","range":"(0,5 - 30,0) mg/dm2"},{"name":"Zakres","range":"(3,0 - 180) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Migracja globalna płynów\nZakres:\nmodelowych − metoda przez całkowite zanurzenie − metoda z zastosowaniem torebki – metoda przez napełnienie wyrobu\nPłyny modelowe: woda kwas octowy 3 % etanol 10 % etanol 20 % etanol 50 %\nZakres (0,5 - 30,0) mg/dm2\nZakres (3,0 - 180) mg/kg\nMetoda wagowa","reference":"PN-EN 1186-3:2023-01 | Rozporządzenie Komisji (WE) Nr 10/2011 z dn. 14 Stycznia 2011 r. (Dz. U. L 12 z 15.1.2011 z późn.zm. zał. III i zał. V)","norm_bases":["PN-EN 1186-3:2023-01","Rozporządzenie Komisji (WE) Nr 10/2011 z dn. 14 Stycznia 2011 r. (Dz. U. L 12 z 15.1.2011 z późn.zm. zał. III i zał. V)"],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością Migracja globalna płynów\nZakres:\nmodelowych − metoda przez całkowite zanurzenie − metoda z zastosowaniem torebki – metoda przez napełnienie wyrobu\nPłyny modelowe: woda kwas octowy 3 % etanol 10 % etanol 20 % etanol 50 %\nZakres (0,5 - 30,0) mg/dm2\nZakres (3,0 - 180) mg/kg\nMetoda wagowa PN-EN 1186-3:2023-01 | Rozporządzenie Komisji (WE) Nr 10/2011 z dn. 14 Stycznia 2011 r. (Dz. U. L 12 z 15.1.2011 z późn.zm. zał. III i zał. V) Materialy i wyroby z tworzyw sztucznych przeznaczone do kontaktu z zywnoscia Migracja globalna plynow\nZakres:\nmodelowych − metoda przez calkowite zanurzenie − metoda z zastosowaniem torebki – metoda przez napelnienie wyrobu\nPlyny modelowe: woda kwas octowy 3 % etanol 10 % etanol 20 % etanol 50 %\nZakres (0,5 - 30,0) mg/dm2\nZakres (3,0 - 180) mg/kg\nMetoda wagowa PN-EN 1186-3:2023-01 | Rozporzadzenie Komisji (WE) Nr 10/2011 z dn. 14 Stycznia 2011 r. (Dz. U. L 12 z 15.1.2011 z pozn.zm. zal. III i zal. V)","categories":["materials","water","food"],"row_index":257,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Overall migration of simulants","parameters_en":[{"name":"simulants − total immersion method − pouch method – article filling method"},{"name":"Simulants: water acetic acid 3 % ethanol 10 % ethanol 20 % ethanol 50 %"},{"name":"Range","range":"(0,5 - 30,0) mg/dm2"},{"name":"Range","range":"(3,0 - 180) mg/kg"}],"search_en":"Plastic materials and articles intended to come into contact with food Overall migration of simulants Gravimetric method simulants − total immersion method − pouch method – article filling method Simulants: water acetic acid 3 % ethanol 10 % ethanol 20 % ethanol 50 % Range Range PN-EN 1186-3:2023-01 | Rozporządzenie Komisji (WE) Nr 10/2011 z dn. 14 Stycznia 2011 r. (Dz. U. L 12 z 15.1.2011 z późn.zm. zał. III i zał. V)","technique_en":"Gravimetric method","test_object_en":"Plastic materials and articles intended to come into contact with food","parameters_zh":[{"name":"modelowych − metoda przez całkowite zanurzenie − metoda z zastosowaniem torebki – metoda przez napełnienie wyrobu"},{"name":"Płyny modelowe: woda kwas octowy 3 % etanol 10 % etanol 20 % etanol 50 %"},{"name":"范围","range":"(0,5 - 30,0) mg/dm2"},{"name":"范围","range":"(3,0 - 180) mg/kg"}],"search_zh":"拟与食品接触的塑料材料及制品 重量法 范围 范围 PN-EN 1186-3:2023-01 | Rozporządzenie Komisji (WE) Nr 10/2011 z dn. 14 Stycznia 2011 r. (Dz. U. L 12 z 15.1.2011 z późn.zm. zał. III i zał. V)","technique_zh":"重量法","test_object_zh":"拟与食品接触的塑料材料及制品"},{"_id":"6a8369ecaf14b9c0e7b1dd24","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością","methodology":"Migracja globalna do mediów substytucyjnych","parameters":[{"name":"izooktan"},{"name":"etanol 95 %"},{"name":"Zakres","range":"(0,5 - 30,0) mg/dm2"},{"name":"Zakres","range":"(3,0 - 180) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Migracja globalna do mediów substytucyjnych\nZakres:\nizooktan\netanol 95 %\nZakres (0,5 - 30,0) mg/dm2\nZakres (3,0 - 180) mg/kg\nMetoda wagowa","reference":"PN-EN 1186-3:2023-01 | Rozporządzenie Komisji (WE) Nr 10/2011 z dn. 14 Stycznia 2011 r. (Dz. U. L 12 z 15.1.2011 z późn.zm. zał. III i zał. V)","norm_bases":["PN-EN 1186-3:2023-01","Rozporządzenie Komisji (WE) Nr 10/2011 z dn. 14 Stycznia 2011 r. (Dz. U. L 12 z 15.1.2011 z późn.zm. zał. III i zał. V)"],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością Migracja globalna do mediów substytucyjnych\nZakres:\nizooktan\netanol 95 %\nZakres (0,5 - 30,0) mg/dm2\nZakres (3,0 - 180) mg/kg\nMetoda wagowa PN-EN 1186-3:2023-01 | Rozporządzenie Komisji (WE) Nr 10/2011 z dn. 14 Stycznia 2011 r. (Dz. U. L 12 z 15.1.2011 z późn.zm. zał. III i zał. V) Materialy i wyroby z tworzyw sztucznych przeznaczone do kontaktu z zywnoscia Migracja globalna do mediow substytucyjnych\nZakres:\nizooktan\netanol 95 %\nZakres (0,5 - 30,0) mg/dm2\nZakres (3,0 - 180) mg/kg\nMetoda wagowa PN-EN 1186-3:2023-01 | Rozporzadzenie Komisji (WE) Nr 10/2011 z dn. 14 Stycznia 2011 r. (Dz. U. L 12 z 15.1.2011 z pozn.zm. zal. III i zal. V)","categories":["materials","food"],"row_index":258,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Overall migration into substitute media","parameters_en":[{"name":"isooctane"},{"name":"ethanol 95 %"},{"name":"Range","range":"(0,5 - 30,0) mg/dm2"},{"name":"Range","range":"(3,0 - 180) mg/kg"}],"search_en":"Plastic materials and articles intended to come into contact with food Overall migration into substitute media Gravimetric method isooctane ethanol 95 % Range Range PN-EN 1186-3:2023-01 | Rozporządzenie Komisji (WE) Nr 10/2011 z dn. 14 Stycznia 2011 r. (Dz. U. L 12 z 15.1.2011 z późn.zm. zał. III i zał. V)","technique_en":"Gravimetric method","test_object_en":"Plastic materials and articles intended to come into contact with food","parameters_zh":[{"name":"异辛烷"},{"name":"etanol 95 %"},{"name":"范围","range":"(0,5 - 30,0) mg/dm2"},{"name":"范围","range":"(3,0 - 180) mg/kg"}],"search_zh":"拟与食品接触的塑料材料及制品 向替代介质的总迁移量 重量法 异辛烷 范围 范围 PN-EN 1186-3:2023-01 | Rozporządzenie Komisji (WE) Nr 10/2011 z dn. 14 Stycznia 2011 r. (Dz. U. L 12 z 15.1.2011 z późn.zm. zał. III i zał. V)","technique_zh":"重量法","test_object_zh":"拟与食品接触的塑料材料及制品","methodology_zh":"向替代介质的总迁移量"},{"_id":"6a8369ecaf14b9c0e7b1dd25","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Żywność E","methodology":"Udział procentowy składników stałych","parameters":[],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Udział procentowy składników stałych\nMetoda wagowa","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Żywność E Udział procentowy składników stałych\nMetoda wagowa Procedury badawcze Zywnosc E Udzial procentowy skladnikow stalych\nMetoda wagowa Procedury badawcze","categories":["food"],"row_index":259,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Percentage share of solid components","search_en":"Food E Percentage share of solid components Gravimetric method Procedury badawcze","technique_en":"Gravimetric method","test_object_en":"Food E","search_zh":"食品 E 重量法 Procedury badawcze","technique_zh":"重量法","test_object_zh":"食品 E"},{"_id":"6a8369ecaf14b9c0e7b1dd26","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość węglowodanów ogółem (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość węglowodanów ogółem (z obliczeń)","reference":"PB-PAZ/FS-19","norm_bases":["PB-PAZ/FS-19"],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Żywność E Zawartość węglowodanów ogółem (z obliczeń) PB-PAZ/FS-19 Zywnosc E Zawartosc weglowodanow ogolem (z obliczen) PB-PAZ/FS-19","categories":["food"],"row_index":260,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total carbohydrate content (calculated)","search_en":"Food E Total carbohydrate content (calculated) PB-PAZ/FS-19","test_object_en":"Food E","search_zh":"食品 E 总碳水化合物含量（由计算得出） PB-PAZ/FS-19","test_object_zh":"食品 E","methodology_zh":"总碳水化合物含量（由计算得出）"},{"_id":"6a8369ecaf14b9c0e7b1dd27","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość węglowodanów przyswajalnych (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość węglowodanów przyswajalnych (z obliczeń)","reference":"PB-PAZ/FS-19","norm_bases":["PB-PAZ/FS-19"],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Żywność E Zawartość węglowodanów przyswajalnych (z obliczeń) PB-PAZ/FS-19 Zywnosc E Zawartosc weglowodanow przyswajalnych (z obliczen) PB-PAZ/FS-19","categories":["food"],"row_index":261,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Available carbohydrate content (calculated)","search_en":"Food E Available carbohydrate content (calculated) PB-PAZ/FS-19","test_object_en":"Food E","search_zh":"食品 E PB-PAZ/FS-19","test_object_zh":"食品 E"},{"_id":"6a8369ecaf14b9c0e7b1dd28","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość błonnika pokarmowego","parameters":[],"technique":"Metoda enzymatyczno-wagowa","techniques":["Metoda enzymatyczno-wagowa"],"computed":[],"activity":"Zawartość błonnika pokarmowego\nMetoda enzymatyczno-wagowa","reference":"PB-PAZ/FS-15","norm_bases":["PB-PAZ/FS-15"],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Żywność E Zawartość błonnika pokarmowego\nMetoda enzymatyczno-wagowa PB-PAZ/FS-15 Zywnosc E Zawartosc blonnika pokarmowego\nMetoda enzymatyczno-wagowa PB-PAZ/FS-15","categories":["food"],"row_index":262,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dietary fibre content","search_en":"Food E Dietary fibre content Enzymatic-gravimetric method PB-PAZ/FS-15","technique_en":"Enzymatic-gravimetric method","test_object_en":"Food E","search_zh":"食品 E 膳食纤维含量 酶-重量法 PB-PAZ/FS-15","test_object_zh":"食品 E","methodology_zh":"膳食纤维含量","technique_zh":"酶-重量法"},{"_id":"6a8369ecaf14b9c0e7b1dd29","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Żywność E","methodology":"pH","parameters":[],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nMetoda potencjometryczna","reference":"PB-PAZ/FS-06","norm_bases":["PB-PAZ/FS-06"],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Żywność E pH\nMetoda potencjometryczna PB-PAZ/FS-06 Zywnosc E pH\nMetoda potencjometryczna PB-PAZ/FS-06","categories":["food"],"row_index":263,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","search_en":"Food E pH Potentiometric method PB-PAZ/FS-06","technique_en":"Potentiometric method","test_object_en":"Food E","methodology_zh":"pH 值","search_zh":"食品 E pH 值 电位法 PB-PAZ/FS-06","technique_zh":"电位法","test_object_zh":"食品 E"},{"_id":"6a8369ecaf14b9c0e7b1dd2a","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość chlorku sodu (NaCl)","parameters":[],"technique":"Metoda miareczkowa (Volharda i Mohra)","techniques":["Metoda miareczkowa (Volharda i Mohra)"],"computed":[],"activity":"Zawartość chlorku sodu (NaCl)\nMetoda miareczkowa (Volharda i Mohra)","reference":"PB-PAZ/FS-09","norm_bases":["PB-PAZ/FS-09"],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Żywność E Zawartość chlorku sodu (NaCl)\nMetoda miareczkowa (Volharda i Mohra) PB-PAZ/FS-09 Zywnosc E Zawartosc chlorku sodu (NaCl)\nMetoda miareczkowa (Volharda i Mohra) PB-PAZ/FS-09","categories":["food"],"row_index":264,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sodium chloride content (NaCl)","search_en":"Food E Sodium chloride content (NaCl) Titrimetric method (Volhard and Mohr) PB-PAZ/FS-09","technique_en":"Titrimetric method (Volhard and Mohr)","test_object_en":"Food E","search_zh":"食品 E PB-PAZ/FS-09","test_object_zh":"食品 E"},{"_id":"6a8369ecaf14b9c0e7b1dd2b","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Żywność E","methodology":"Obecność zanieczyszczeń nieorganicznych (mineralnych, ferromagnetycznych) i organicznych","parameters":[],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Obecność zanieczyszczeń nieorganicznych (mineralnych, ferromagnetycznych) i organicznych\nMetoda wizualna","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Żywność E Obecność zanieczyszczeń nieorganicznych (mineralnych, ferromagnetycznych) i organicznych\nMetoda wizualna Procedury badawcze Zywnosc E Obecnosc zanieczyszczen nieorganicznych (mineralnych, ferromagnetycznych) i organicznych\nMetoda wizualna Procedury badawcze","categories":["food"],"row_index":265,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of inorganic (mineral, ferromagnetic) and organic impurities","search_en":"Food E Presence of inorganic (mineral, ferromagnetic) and organic impurities Visual method Procedury badawcze","technique_en":"Visual method","test_object_en":"Food E","search_zh":"食品 E 目视法 Procedury badawcze","technique_zh":"目视法","test_object_zh":"食品 E"},{"_id":"6a8369ecaf14b9c0e7b1dd2c","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Żywność E","methodology":"Kwasowość ogólna","parameters":[],"technique":"Metoda miareczkowania potencjometrycznego","techniques":["Metoda miareczkowania potencjometrycznego"],"computed":[],"activity":"Kwasowość ogólna\nMetoda miareczkowania potencjometrycznego","reference":"PB-PAZ/FS-08","norm_bases":["PB-PAZ/FS-08"],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Żywność E Kwasowość ogólna\nMetoda miareczkowania potencjometrycznego PB-PAZ/FS-08 Zywnosc E Kwasowosc ogolna\nMetoda miareczkowania potencjometrycznego PB-PAZ/FS-08","categories":["food"],"row_index":266,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total acidity","search_en":"Food E Total acidity Potentiometric titration method PB-PAZ/FS-08","technique_en":"Potentiometric titration method","test_object_en":"Food E","search_zh":"食品 E 总酸度 电位滴定法 PB-PAZ/FS-08","technique_zh":"电位滴定法","test_object_zh":"食品 E","methodology_zh":"总酸度"},{"_id":"6a8369ecaf14b9c0e7b1dd2d","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość tłuszczu całkowitego","parameters":[],"technique":"Metoda ekstrakcyjno-wagowa (Soxhleta)","techniques":["Metoda ekstrakcyjno-wagowa (Soxhleta)"],"computed":[],"activity":"Zawartość tłuszczu całkowitego\nMetoda ekstrakcyjno-wagowa (Soxhleta)","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Żywność E Zawartość tłuszczu całkowitego\nMetoda ekstrakcyjno-wagowa (Soxhleta) Procedury badawcze Zywnosc E Zawartosc tluszczu calkowitego\nMetoda ekstrakcyjno-wagowa (Soxhleta) Procedury badawcze","categories":["food"],"row_index":267,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total fat content","search_en":"Food E Total fat content Extraction-gravimetric method (Soxhlet) Procedury badawcze","technique_en":"Extraction-gravimetric method (Soxhlet)","test_object_en":"Food E","search_zh":"食品 E 总脂肪含量 萃取-重量法（索氏抽提） Procedury badawcze","test_object_zh":"食品 E","methodology_zh":"总脂肪含量","technique_zh":"萃取-重量法（索氏抽提）"},{"_id":"6a8369ecaf14b9c0e7b1dd2e","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość produktu z wadami 2)","parameters":[],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość produktu z wadami 2)\nMetoda wagowa","reference":"PB-PAZ/FS-21","norm_bases":["PB-PAZ/FS-21"],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Żywność E Zawartość produktu z wadami 2)\nMetoda wagowa PB-PAZ/FS-21 Zywnosc E Zawartosc produktu z wadami 2)\nMetoda wagowa PB-PAZ/FS-21","categories":["food"],"row_index":268,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of product with defects 2)","search_en":"Food E Content of product with defects 2) Gravimetric method PB-PAZ/FS-21","technique_en":"Gravimetric method","test_object_en":"Food E","search_zh":"食品 E 重量法 PB-PAZ/FS-21","technique_zh":"重量法","test_object_zh":"食品 E"},{"_id":"6a8369ecaf14b9c0e7b1dd2f","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Żywność E","methodology":"Wartość energetyczna (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wartość energetyczna (z obliczeń)","reference":"Rozporządzanie Parlamentu Europejskiego i Rady (UE) nr 1169/2011 4)","norm_bases":["Rozporządzanie Parlamentu Europejskiego i Rady (UE) nr 1169/2011 4)"],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Żywność E Wartość energetyczna (z obliczeń) Rozporządzanie Parlamentu Europejskiego i Rady (UE) nr 1169/2011 4) Zywnosc E Wartosc energetyczna (z obliczen) Rozporzadzanie Parlamentu Europejskiego i Rady (UE) nr 1169/2011 4)","categories":["food"],"row_index":269,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Energy value (calculated)","search_en":"Food E Energy value (calculated) Rozporządzanie Parlamentu Europejskiego i Rady (UE) nr 1169/2011 4)","test_object_en":"Food E","search_zh":"食品 E 能量值（由计算得出） Rozporządzanie Parlamentu Europejskiego i Rady (UE) nr 1169/2011 4)","test_object_zh":"食品 E","methodology_zh":"能量值（由计算得出）"},{"_id":"6a8369ecaf14b9c0e7b1dd30","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Żywność E","methodology":"Cechy sensoryczne","parameters":[],"technique":"Prosty test opisowy","techniques":["Prosty test opisowy"],"computed":[],"activity":"Cechy sensoryczne\nProsty test opisowy","reference":"PB-PAZ/FS-33","norm_bases":["PB-PAZ/FS-33"],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Żywność E Cechy sensoryczne\nProsty test opisowy PB-PAZ/FS-33 Zywnosc E Cechy sensoryczne\nProsty test opisowy PB-PAZ/FS-33","categories":["food"],"row_index":270,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sensory characteristics","search_en":"Food E Sensory characteristics Simple descriptive test PB-PAZ/FS-33","technique_en":"Simple descriptive test","test_object_en":"Food E","search_zh":"食品 E 感官特性 PB-PAZ/FS-33","test_object_zh":"食品 E","methodology_zh":"感官特性"},{"_id":"6a8369ecaf14b9c0e7b1dd31","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Pasze E, Karmy dla zwierząt E","methodology":"Cechy sensoryczne","parameters":[],"technique":"Prosty test opisowy","techniques":["Prosty test opisowy"],"computed":[],"activity":"Cechy sensoryczne\nProsty test opisowy","reference":"PB-PAZ/FS-33","norm_bases":["PB-PAZ/FS-33"],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pasze E, Karmy dla zwierząt E Cechy sensoryczne\nProsty test opisowy PB-PAZ/FS-33 Pasze E, Karmy dla zwierzat E Cechy sensoryczne\nProsty test opisowy PB-PAZ/FS-33","categories":["food"],"row_index":271,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sensory characteristics","search_en":"Sensory characteristics Simple descriptive test PB-PAZ/FS-33","technique_en":"Simple descriptive test","methodology_zh":"感官特性","search_zh":"感官特性 PB-PAZ/FS-33"},{"_id":"6a8369ecaf14b9c0e7b1dd32","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Żywność E, Pasze E","methodology":"Zawartość popiołu, Nierozpuszczalnego","parameters":[],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość popiołu, Nierozpuszczalnego\nMetoda wagowa","reference":"PB-PAZ/FS-12","norm_bases":["PB-PAZ/FS-12"],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Żywność E, Pasze E Zawartość popiołu, Nierozpuszczalnego\nMetoda wagowa PB-PAZ/FS-12 Zywnosc E, Pasze E Zawartosc popiolu, Nierozpuszczalnego\nMetoda wagowa PB-PAZ/FS-12","categories":["food"],"row_index":272,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ash content, Insoluble","search_en":"Food E, Feed E Ash content, Insoluble Gravimetric method PB-PAZ/FS-12","technique_en":"Gravimetric method","test_object_en":"Food E, Feed E","search_zh":"食品 E、饲料 E 重量法 PB-PAZ/FS-12","technique_zh":"重量法","test_object_zh":"食品 E、饲料 E"},{"_id":"6a8369ecaf14b9c0e7b1dd33","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Żywność E, Pasze E","methodology":"Zawartość azotu Kjeldahla","parameters":[{"name":"Zawartość białka (z obliczeń)"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu Kjeldahla\nZawartość białka (z obliczeń)\nMetoda miareczkowa","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Żywność E, Pasze E Zawartość azotu Kjeldahla\nZawartość białka (z obliczeń)\nMetoda miareczkowa Procedury badawcze Zywnosc E, Pasze E Zawartosc azotu Kjeldahla\nZawartosc bialka (z obliczen)\nMetoda miareczkowa Procedury badawcze","categories":["food"],"row_index":273,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen content","parameters_en":[{"name":"Protein content (calculated)"}],"search_en":"Food E, Feed E Kjeldahl nitrogen content Titrimetric method Protein content (calculated) Procedury badawcze","technique_en":"Titrimetric method","test_object_en":"Food E, Feed E","search_zh":"食品 E、饲料 E 凯氏氮含量 滴定法 蛋白质含量（计算值） Procedury badawcze","technique_zh":"滴定法","methodology_zh":"凯氏氮含量","parameters_zh":[{"name":"蛋白质含量（计算值）"}],"test_object_zh":"食品 E、饲料 E"},{"_id":"6a8369ecaf14b9c0e7b1dd34","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Żywność E, Pasze E","methodology":"Zawartość popiołu ogólnego","parameters":[],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość popiołu ogólnego\nMetoda wagowa","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Żywność E, Pasze E Zawartość popiołu ogólnego\nMetoda wagowa Procedury badawcze Zywnosc E, Pasze E Zawartosc popiolu ogolnego\nMetoda wagowa Procedury badawcze","categories":["food"],"row_index":274,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total ash content","search_en":"Food E, Feed E Total ash content Gravimetric method Procedury badawcze","technique_en":"Gravimetric method","test_object_en":"Food E, Feed E","search_zh":"食品 E、饲料 E 总灰分含量 重量法 Procedury badawcze","technique_zh":"重量法","methodology_zh":"总灰分含量","test_object_zh":"食品 E、饲料 E"},{"_id":"6a8369ecaf14b9c0e7b1dd35","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Żywność E, Pasze E","methodology":"Zawartość suchej masy","parameters":[],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość suchej masy\nMetoda wagowa","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Żywność E, Pasze E Zawartość suchej masy\nMetoda wagowa Procedury badawcze Zywnosc E, Pasze E Zawartosc suchej masy\nMetoda wagowa Procedury badawcze","categories":["food"],"row_index":275,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry matter content","search_en":"Food E, Feed E Dry matter content Gravimetric method Procedury badawcze","technique_en":"Gravimetric method","test_object_en":"Food E, Feed E","search_zh":"食品 E、饲料 E 干物质含量 重量法 Procedury badawcze","technique_zh":"重量法","methodology_zh":"干物质含量","test_object_zh":"食品 E、饲料 E"},{"_id":"6a8369ecaf14b9c0e7b1dd36","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Żywność E, Pasze E","methodology":"Zawartość wody","parameters":[],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wody\nMetoda wagowa","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Żywność E, Pasze E Zawartość wody\nMetoda wagowa Procedury badawcze Zywnosc E, Pasze E Zawartosc wody\nMetoda wagowa Procedury badawcze","categories":["food","water"],"row_index":276,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water content","search_en":"Food E, Feed E Water content Gravimetric method Procedury badawcze","technique_en":"Gravimetric method","test_object_en":"Food E, Feed E","methodology_zh":"水分含量","search_zh":"食品 E、饲料 E 水分含量 重量法 Procedury badawcze","technique_zh":"重量法","test_object_zh":"食品 E、饲料 E"},{"_id":"6a8369ecaf14b9c0e7b1dd37","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Żywność E, Pasze E","methodology":"Zawartość tłuszczu wolnego","parameters":[],"technique":"Metoda ekstrakcyjno-wagowa (Soxhleta)","techniques":["Metoda ekstrakcyjno-wagowa (Soxhleta)"],"computed":[],"activity":"Zawartość tłuszczu wolnego\nMetoda ekstrakcyjno-wagowa (Soxhleta)","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Żywność E, Pasze E Zawartość tłuszczu wolnego\nMetoda ekstrakcyjno-wagowa (Soxhleta) Procedury badawcze Zywnosc E, Pasze E Zawartosc tluszczu wolnego\nMetoda ekstrakcyjno-wagowa (Soxhleta) Procedury badawcze","categories":["food"],"row_index":277,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free fat content","search_en":"Food E, Feed E Free fat content Extraction-gravimetric method (Soxhlet) Procedury badawcze","technique_en":"Extraction-gravimetric method (Soxhlet)","test_object_en":"Food E, Feed E","methodology_zh":"游离脂肪含量","search_zh":"食品 E、饲料 E 游离脂肪含量 萃取-重量法（索氏抽提） Procedury badawcze","test_object_zh":"食品 E、饲料 E","technique_zh":"萃取-重量法（索氏抽提）"},{"_id":"6a8369ecaf14b9c0e7b1dd38","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Żywność E, Pasze E","methodology":"Masa netto, Masa brutto","parameters":[],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Masa netto, Masa brutto\nMetoda wagowa","reference":"PB-PAZ/FS-21","norm_bases":["PB-PAZ/FS-21"],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Żywność E, Pasze E Masa netto, Masa brutto\nMetoda wagowa PB-PAZ/FS-21 Zywnosc E, Pasze E Masa netto, Masa brutto\nMetoda wagowa PB-PAZ/FS-21","categories":["food"],"row_index":278,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Net mass, Gross mass","search_en":"Food E, Feed E Net mass, Gross mass Gravimetric method PB-PAZ/FS-21","technique_en":"Gravimetric method","test_object_en":"Food E, Feed E","search_zh":"食品 E、饲料 E 重量法 PB-PAZ/FS-21","technique_zh":"重量法","test_object_zh":"食品 E、饲料 E"},{"_id":"6a8369ecaf14b9c0e7b1dd39","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Żywność E, Pasze E","methodology":"Liczba kwasowa","parameters":[],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Liczba kwasowa\nMetoda miareczkowa","reference":"PB-PAZ/FS-24","norm_bases":["PB-PAZ/FS-24"],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Żywność E, Pasze E Liczba kwasowa\nMetoda miareczkowa PB-PAZ/FS-24 Zywnosc E, Pasze E Liczba kwasowa\nMetoda miareczkowa PB-PAZ/FS-24","categories":["food"],"row_index":279,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Acid value","search_en":"Food E, Feed E Acid value Titrimetric method PB-PAZ/FS-24","technique_en":"Titrimetric method","test_object_en":"Food E, Feed E","search_zh":"食品 E、饲料 E 酸值 滴定法 PB-PAZ/FS-24","technique_zh":"滴定法","methodology_zh":"酸值","test_object_zh":"食品 E、饲料 E"},{"_id":"6a8369ecaf14b9c0e7b1dd3a","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Żywność E, Pasze E","methodology":"Liczba nadtlenkowa","parameters":[],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Liczba nadtlenkowa\nMetoda miareczkowa","reference":"PB-PAZ/FS-17","norm_bases":["PB-PAZ/FS-17"],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Żywność E, Pasze E Liczba nadtlenkowa\nMetoda miareczkowa PB-PAZ/FS-17 Zywnosc E, Pasze E Liczba nadtlenkowa\nMetoda miareczkowa PB-PAZ/FS-17","categories":["food"],"row_index":280,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Peroxide value","search_en":"Food E, Feed E Peroxide value Titrimetric method PB-PAZ/FS-17","technique_en":"Titrimetric method","test_object_en":"Food E, Feed E","search_zh":"食品 E、饲料 E 过氧化值 滴定法 PB-PAZ/FS-17","technique_zh":"滴定法","methodology_zh":"过氧化值","test_object_zh":"食品 E、饲料 E"},{"_id":"6a8369ecaf14b9c0e7b1dd3b","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Żywność E, Pasze E","methodology":"Zawartość rtęci","parameters":[],"technique":"Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","techniques":["Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji"],"computed":[],"activity":"Zawartość rtęci\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","reference":"PB-PAZ/FS-42","norm_bases":["PB-PAZ/FS-42"],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze E Zawartość rtęci\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji PB-PAZ/FS-42 Zywnosc E, Pasze E Zawartosc rteci\nMetoda absorpcyjnej spektrometrii atomowej z technika amalgamacji PB-PAZ/FS-42","categories":["food"],"row_index":281,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Food E, Feed E Mercury content Atomic absorption spectrometry with amalgamation technique E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PB-PAZ/FS-42","technique_en":"Atomic absorption spectrometry with amalgamation technique","test_object_en":"Food E, Feed E","methodology_zh":"汞含量","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"食品 E、饲料 E 汞含量 原子吸收光谱法（汞齐化技术） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PB-PAZ/FS-42","technique_zh":"原子吸收光谱法（汞齐化技术）","test_object_zh":"食品 E、饲料 E"},{"_id":"6a8369ecaf14b9c0e7b1dd3c","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Żywność E, Pasze E","methodology":"Zawartość pierwiastków","parameters":[],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"computed":[],"activity":"Zawartość pierwiastków\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"PB-PAZ/FS-41","norm_bases":["PB-PAZ/FS-41"],"lab_section":"Pracownia Badań Żywności, Dział Fizykochemii i Sensoryki","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Pasze E Zawartość pierwiastków\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) PB-PAZ/FS-41 Zywnosc E, Pasze E Zawartosc pierwiastkow\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) PB-PAZ/FS-41","categories":["food"],"row_index":282,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Food E, Feed E Element content Inductively coupled plasma mass spectrometry (ICP-MS) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PB-PAZ/FS-41","technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","test_object_en":"Food E, Feed E","methodology_zh":"元素含量","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"食品 E、饲料 E 元素含量 电感耦合等离子体质谱法（ICP-MS） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PB-PAZ/FS-41","technique_zh":"电感耦合等离子体质谱法（ICP-MS）","test_object_zh":"食品 E、饲料 E"},{"_id":"6a8369ecaf14b9c0e7b1dd3d","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Wyroby i materiały metalowe","methodology":"Niedoskonałości kształtu oraz nieciągłości powierzchniowe","parameters":[],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Niedoskonałości kształtu oraz nieciągłości powierzchniowe\nMetoda wizualna","reference":"PN-EN 13018:2016-04","norm_bases":["PN-EN 13018:2016-04"],"lab_section":"Pracownia Badań Nieniszczących","lab_address":null,"regulatory_area":"Potwierdzono kompetencje personelu do formułowania opinii i interpretacji na podstawie wyników badań wykonywanych w ww. Pracowni.","flexible":false,"search_text":"Wyroby i materiały metalowe Niedoskonałości kształtu oraz nieciągłości powierzchniowe\nMetoda wizualna PN-EN 13018:2016-04 Wyroby i materialy metalowe Niedoskonalosci ksztaltu oraz nieciaglosci powierzchniowe\nMetoda wizualna PN-EN 13018:2016-04","categories":["materials"],"row_index":283,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Shape imperfections and surface discontinuities","search_en":"Metal products and materials Shape imperfections and surface discontinuities Visual method PN-EN 13018:2016-04","technique_en":"Visual method","test_object_en":"Metal products and materials","search_zh":"金属制品与材料 形状缺陷与表面不连续性 目视法 PN-EN 13018:2016-04","technique_zh":"目视法","test_object_zh":"金属制品与材料","methodology_zh":"形状缺陷与表面不连续性"},{"_id":"6a8369ecaf14b9c0e7b1dd3e","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Złącza spawane materiałów","methodology":"Niedoskonałości kształtu oraz nieciągłości powierzchniowe","parameters":[],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Niedoskonałości kształtu oraz nieciągłości powierzchniowe\nMetoda wizualna","reference":"PN-EN ISO 17637:2017-02","norm_bases":["PN-EN ISO 17637:2017-02"],"lab_section":"Pracownia Badań Nieniszczących","lab_address":null,"regulatory_area":"Potwierdzono kompetencje personelu do formułowania opinii i interpretacji na podstawie wyników badań wykonywanych w ww. Pracowni.","flexible":false,"search_text":"Złącza spawane materiałów Niedoskonałości kształtu oraz nieciągłości powierzchniowe\nMetoda wizualna PN-EN ISO 17637:2017-02 Zlacza spawane materialow Niedoskonalosci ksztaltu oraz nieciaglosci powierzchniowe\nMetoda wizualna PN-EN ISO 17637:2017-02","categories":["materials"],"row_index":284,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Shape imperfections and surface discontinuities","search_en":"Shape imperfections and surface discontinuities Visual method PN-EN ISO 17637:2017-02","technique_en":"Visual method","search_zh":"形状缺陷与表面不连续性 目视法 PN-EN ISO 17637:2017-02","technique_zh":"目视法","methodology_zh":"形状缺陷与表面不连续性"},{"_id":"6a8369ecaf14b9c0e7b1dd3f","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Wyroby i materiały","methodology":"Nieciągłości powierzchniowe i podpowierzchniowe leżące na głębokości nie większej niż 2 mm","parameters":[],"technique":"Metoda magnetyczno-proszkowa","techniques":["Metoda magnetyczno-proszkowa"],"computed":[],"activity":"Nieciągłości powierzchniowe i podpowierzchniowe leżące na głębokości nie większej niż 2 mm\nMetoda magnetyczno-proszkowa","reference":"PN-EN ISO 9934-1:2017-02","norm_bases":["PN-EN ISO 9934-1:2017-02"],"lab_section":"Pracownia Badań Nieniszczących","lab_address":null,"regulatory_area":"Potwierdzono kompetencje personelu do formułowania opinii i interpretacji na podstawie wyników badań wykonywanych w ww. Pracowni.","flexible":false,"search_text":"Wyroby i materiały Nieciągłości powierzchniowe i podpowierzchniowe leżące na głębokości nie większej niż 2 mm\nMetoda magnetyczno-proszkowa PN-EN ISO 9934-1:2017-02 Wyroby i materialy Nieciaglosci powierzchniowe i podpowierzchniowe lezace na glebokosci nie wiekszej niz 2 mm\nMetoda magnetyczno-proszkowa PN-EN ISO 9934-1:2017-02","categories":["materials"],"row_index":285,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Surface and subsurface discontinuities lying at a depth of no more than 2 mm","search_en":"Surface and subsurface discontinuities lying at a depth of no more than 2 mm Magnetic particle method PN-EN ISO 9934-1:2017-02","technique_en":"Magnetic particle method","search_zh":"深度不超过 2 mm 的表面与近表面不连续性 磁粉检测法 PN-EN ISO 9934-1:2017-02","technique_zh":"磁粉检测法","methodology_zh":"深度不超过 2 mm 的表面与近表面不连续性"},{"_id":"6a8369ecaf14b9c0e7b1dd40","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Złącza spawane materiałów","methodology":"Nieciągłości powierzchniowe i podpowierzchniowe leżące na głębokości nie większej niż 2 mm","parameters":[],"technique":"Metoda magnetyczno-proszkowa","techniques":["Metoda magnetyczno-proszkowa"],"computed":[],"activity":"Nieciągłości powierzchniowe i podpowierzchniowe leżące na głębokości nie większej niż 2 mm\nMetoda magnetyczno-proszkowa","reference":"PN-EN ISO 17638:2017-01","norm_bases":["PN-EN ISO 17638:2017-01"],"lab_section":"Pracownia Badań Nieniszczących","lab_address":null,"regulatory_area":"Potwierdzono kompetencje personelu do formułowania opinii i interpretacji na podstawie wyników badań wykonywanych w ww. Pracowni.","flexible":false,"search_text":"Złącza spawane materiałów Nieciągłości powierzchniowe i podpowierzchniowe leżące na głębokości nie większej niż 2 mm\nMetoda magnetyczno-proszkowa PN-EN ISO 17638:2017-01 Zlacza spawane materialow Nieciaglosci powierzchniowe i podpowierzchniowe lezace na glebokosci nie wiekszej niz 2 mm\nMetoda magnetyczno-proszkowa PN-EN ISO 17638:2017-01","categories":["materials"],"row_index":286,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Surface and subsurface discontinuities lying at a depth of no more than 2 mm","search_en":"Surface and subsurface discontinuities lying at a depth of no more than 2 mm Magnetic particle method PN-EN ISO 17638:2017-01","technique_en":"Magnetic particle method","search_zh":"深度不超过 2 mm 的表面与近表面不连续性 磁粉检测法 PN-EN ISO 17638:2017-01","technique_zh":"磁粉检测法","methodology_zh":"深度不超过 2 mm 的表面与近表面不连续性"},{"_id":"6a8369ecaf14b9c0e7b1dd41","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Odlewy z ferromagnetycznego żeliwa i staliwa","methodology":"Nieciągłości powierzchniowe i podpowierzchniowe leżące na głębokości nie większej niż 2 mm","parameters":[],"technique":"Metoda magnetyczno-proszkowa","techniques":["Metoda magnetyczno-proszkowa"],"computed":[],"activity":"Nieciągłości powierzchniowe i podpowierzchniowe leżące na głębokości nie większej niż 2 mm\nMetoda magnetyczno-proszkowa","reference":"PN-EN 1369:2013-04","norm_bases":["PN-EN 1369:2013-04"],"lab_section":"Pracownia Badań Nieniszczących","lab_address":null,"regulatory_area":"Potwierdzono kompetencje personelu do formułowania opinii i interpretacji na podstawie wyników badań wykonywanych w ww. Pracowni.","flexible":false,"search_text":"Odlewy z ferromagnetycznego żeliwa i staliwa Nieciągłości powierzchniowe i podpowierzchniowe leżące na głębokości nie większej niż 2 mm\nMetoda magnetyczno-proszkowa PN-EN 1369:2013-04 Odlewy z ferromagnetycznego zeliwa i staliwa Nieciaglosci powierzchniowe i podpowierzchniowe lezace na glebokosci nie wiekszej niz 2 mm\nMetoda magnetyczno-proszkowa PN-EN 1369:2013-04","categories":["other"],"row_index":287,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Surface and subsurface discontinuities lying at a depth of no more than 2 mm","search_en":"Castings of ferromagnetic cast iron and cast steel Surface and subsurface discontinuities lying at a depth of no more than 2 mm Magnetic particle method PN-EN 1369:2013-04","technique_en":"Magnetic particle method","test_object_en":"Castings of ferromagnetic cast iron and cast steel","search_zh":"深度不超过 2 mm 的表面与近表面不连续性 磁粉检测法 PN-EN 1369:2013-04","technique_zh":"磁粉检测法","methodology_zh":"深度不超过 2 mm 的表面与近表面不连续性"},{"_id":"6a8369ecaf14b9c0e7b1dd42","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Odkuwki stalowe","methodology":"Nieciągłości powierzchniowe i podpowierzchniowe leżące na głębokości nie większej niż 2 mm","parameters":[],"technique":"Metoda magnetyczno-proszkowa","techniques":["Metoda magnetyczno-proszkowa"],"computed":[],"activity":"Nieciągłości powierzchniowe i podpowierzchniowe leżące na głębokości nie większej niż 2 mm\nMetoda magnetyczno-proszkowa","reference":"PN-EN 10228-1:2016-07","norm_bases":["PN-EN 10228-1:2016-07"],"lab_section":"Pracownia Badań Nieniszczących","lab_address":null,"regulatory_area":"Potwierdzono kompetencje personelu do formułowania opinii i interpretacji na podstawie wyników badań wykonywanych w ww. Pracowni.","flexible":false,"search_text":"Odkuwki stalowe Nieciągłości powierzchniowe i podpowierzchniowe leżące na głębokości nie większej niż 2 mm\nMetoda magnetyczno-proszkowa PN-EN 10228-1:2016-07 Odkuwki stalowe Nieciaglosci powierzchniowe i podpowierzchniowe lezace na glebokosci nie wiekszej niz 2 mm\nMetoda magnetyczno-proszkowa PN-EN 10228-1:2016-07","categories":["materials"],"row_index":288,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Surface and subsurface discontinuities lying at a depth of no more than 2 mm","search_en":"Steel forgings Surface and subsurface discontinuities lying at a depth of no more than 2 mm Magnetic particle method PN-EN 10228-1:2016-07","technique_en":"Magnetic particle method","test_object_en":"Steel forgings","search_zh":"钢锻件 深度不超过 2 mm 的表面与近表面不连续性 磁粉检测法 PN-EN 10228-1:2016-07","technique_zh":"磁粉检测法","test_object_zh":"钢锻件","methodology_zh":"深度不超过 2 mm 的表面与近表面不连续性"},{"_id":"6a8369ecaf14b9c0e7b1dd43","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Rury stalowe ferromagnetyczne","methodology":"Nieciągłości powierzchniowe i podpowierzchniowe leżące na głębokości nie większej niż 2 mm","parameters":[],"technique":"Metoda magnetyczno-proszkowa","techniques":["Metoda magnetyczno-proszkowa"],"computed":[],"activity":"Nieciągłości powierzchniowe i podpowierzchniowe leżące na głębokości nie większej niż 2 mm\nMetoda magnetyczno-proszkowa","reference":"PN-EN ISO 10893-5:2011","norm_bases":["PN-EN ISO 10893-5:2011"],"lab_section":"Pracownia Badań Nieniszczących","lab_address":null,"regulatory_area":"Potwierdzono kompetencje personelu do formułowania opinii i interpretacji na podstawie wyników badań wykonywanych w ww. Pracowni.","flexible":false,"search_text":"Rury stalowe ferromagnetyczne Nieciągłości powierzchniowe i podpowierzchniowe leżące na głębokości nie większej niż 2 mm\nMetoda magnetyczno-proszkowa PN-EN ISO 10893-5:2011 Rury stalowe ferromagnetyczne Nieciaglosci powierzchniowe i podpowierzchniowe lezace na glebokosci nie wiekszej niz 2 mm\nMetoda magnetyczno-proszkowa PN-EN ISO 10893-5:2011","categories":["materials"],"row_index":289,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Surface and subsurface discontinuities lying at a depth of no more than 2 mm","search_en":"Ferromagnetic steel pipes Surface and subsurface discontinuities lying at a depth of no more than 2 mm Magnetic particle method PN-EN ISO 10893-5:2011","technique_en":"Magnetic particle method","test_object_en":"Ferromagnetic steel pipes","search_zh":"铁磁性钢管 深度不超过 2 mm 的表面与近表面不连续性 磁粉检测法 PN-EN ISO 10893-5:2011","technique_zh":"磁粉检测法","test_object_zh":"铁磁性钢管","methodology_zh":"深度不超过 2 mm 的表面与近表面不连续性"},{"_id":"6a8369ecaf14b9c0e7b1dd44","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Wyroby i materiały metalowe","methodology":"Nieciągłości otwarte na badaną powierzchnię","parameters":[],"technique":"Metoda penetracyjna","techniques":["Metoda penetracyjna"],"computed":[],"activity":"Nieciągłości otwarte na badaną powierzchnię\nMetoda penetracyjna","reference":"PN-EN ISO 3452-1:2021-12","norm_bases":["PN-EN ISO 3452-1:2021-12"],"lab_section":"Pracownia Badań Nieniszczących","lab_address":null,"regulatory_area":"Potwierdzono kompetencje personelu do formułowania opinii i interpretacji na podstawie wyników badań wykonywanych w ww. Pracowni.","flexible":false,"search_text":"Wyroby i materiały metalowe Nieciągłości otwarte na badaną powierzchnię\nMetoda penetracyjna PN-EN ISO 3452-1:2021-12 Wyroby i materialy metalowe Nieciaglosci otwarte na badana powierzchnie\nMetoda penetracyjna PN-EN ISO 3452-1:2021-12","categories":["materials"],"row_index":290,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Discontinuities open to the tested surface","search_en":"Metal products and materials Discontinuities open to the tested surface Penetrant testing method PN-EN ISO 3452-1:2021-12","technique_en":"Penetrant testing method","test_object_en":"Metal products and materials","search_zh":"金属制品与材料 向受检表面开口的不连续性 渗透检测法 PN-EN ISO 3452-1:2021-12","test_object_zh":"金属制品与材料","technique_zh":"渗透检测法","methodology_zh":"向受检表面开口的不连续性"},{"_id":"6a8369ecaf14b9c0e7b1dd45","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Odlewy metalowe","methodology":"Nieciągłości otwarte na badaną powierzchnię","parameters":[],"technique":"Metoda penetracyjna","techniques":["Metoda penetracyjna"],"computed":[],"activity":"Nieciągłości otwarte na badaną powierzchnię\nMetoda penetracyjna","reference":"PN-EN 1371-1:2012 | PN-EN 1371-2:2015-03","norm_bases":["PN-EN 1371-1:2012","PN-EN 1371-2:2015-03"],"lab_section":"Pracownia Badań Nieniszczących","lab_address":null,"regulatory_area":"Potwierdzono kompetencje personelu do formułowania opinii i interpretacji na podstawie wyników badań wykonywanych w ww. Pracowni.","flexible":false,"search_text":"Odlewy metalowe Nieciągłości otwarte na badaną powierzchnię\nMetoda penetracyjna PN-EN 1371-1:2012 | PN-EN 1371-2:2015-03 Odlewy metalowe Nieciaglosci otwarte na badana powierzchnie\nMetoda penetracyjna PN-EN 1371-1:2012 | PN-EN 1371-2:2015-03","categories":["materials"],"row_index":291,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Discontinuities open to the tested surface","search_en":"Metal castings Discontinuities open to the tested surface Penetrant testing method PN-EN 1371-1:2012 | PN-EN 1371-2:2015-03","technique_en":"Penetrant testing method","test_object_en":"Metal castings","search_zh":"向受检表面开口的不连续性 渗透检测法 PN-EN 1371-1:2012 | PN-EN 1371-2:2015-03","technique_zh":"渗透检测法","methodology_zh":"向受检表面开口的不连续性"},{"_id":"6a8369ecaf14b9c0e7b1dd46","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Odkuwki stalowe","methodology":"Nieciągłości otwarte na badaną powierzchnię","parameters":[],"technique":"Metoda penetracyjna","techniques":["Metoda penetracyjna"],"computed":[],"activity":"Nieciągłości otwarte na badaną powierzchnię\nMetoda penetracyjna","reference":"PN-EN 10228-2:2016-07","norm_bases":["PN-EN 10228-2:2016-07"],"lab_section":"Pracownia Badań Nieniszczących","lab_address":null,"regulatory_area":"Potwierdzono kompetencje personelu do formułowania opinii i interpretacji na podstawie wyników badań wykonywanych w ww. Pracowni.","flexible":false,"search_text":"Odkuwki stalowe Nieciągłości otwarte na badaną powierzchnię\nMetoda penetracyjna PN-EN 10228-2:2016-07 Odkuwki stalowe Nieciaglosci otwarte na badana powierzchnie\nMetoda penetracyjna PN-EN 10228-2:2016-07","categories":["materials"],"row_index":292,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Discontinuities open to the tested surface","search_en":"Steel forgings Discontinuities open to the tested surface Penetrant testing method PN-EN 10228-2:2016-07","technique_en":"Penetrant testing method","test_object_en":"Steel forgings","search_zh":"钢锻件 向受检表面开口的不连续性 渗透检测法 PN-EN 10228-2:2016-07","technique_zh":"渗透检测法","test_object_zh":"钢锻件","methodology_zh":"向受检表面开口的不连续性"},{"_id":"6a8369ecaf14b9c0e7b1dd47","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Rury stalowe","methodology":"Nieciągłości otwarte na badaną powierzchnię","parameters":[],"technique":"Metoda penetracyjna","techniques":["Metoda penetracyjna"],"computed":[],"activity":"Nieciągłości otwarte na badaną powierzchnię\nMetoda penetracyjna","reference":"PN-EN ISO 10893-4:2011","norm_bases":["PN-EN ISO 10893-4:2011"],"lab_section":"Pracownia Badań Nieniszczących","lab_address":null,"regulatory_area":"Potwierdzono kompetencje personelu do formułowania opinii i interpretacji na podstawie wyników badań wykonywanych w ww. Pracowni.","flexible":false,"search_text":"Rury stalowe Nieciągłości otwarte na badaną powierzchnię\nMetoda penetracyjna PN-EN ISO 10893-4:2011 Rury stalowe Nieciaglosci otwarte na badana powierzchnie\nMetoda penetracyjna PN-EN ISO 10893-4:2011","categories":["materials"],"row_index":293,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Discontinuities open to the tested surface","search_en":"Steel pipes Discontinuities open to the tested surface Penetrant testing method PN-EN ISO 10893-4:2011","technique_en":"Penetrant testing method","test_object_en":"Steel pipes","search_zh":"钢管 向受检表面开口的不连续性 渗透检测法 PN-EN ISO 10893-4:2011","technique_zh":"渗透检测法","test_object_zh":"钢管","methodology_zh":"向受检表面开口的不连续性"},{"_id":"6a8369ecaf14b9c0e7b1dd48","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Wyroby i materiały metalowe","methodology":"Nieciągłości","parameters":[],"technique":"Metoda radiograficzna","techniques":["Metoda radiograficzna"],"computed":[],"activity":"Nieciągłości\nMetoda radiograficzna","reference":"PN-EN ISO 5579:2014-02","norm_bases":["PN-EN ISO 5579:2014-02"],"lab_section":"Pracownia Badań Nieniszczących","lab_address":null,"regulatory_area":"Potwierdzono kompetencje personelu do formułowania opinii i interpretacji na podstawie wyników badań wykonywanych w ww. Pracowni.","flexible":false,"search_text":"Wyroby i materiały metalowe Nieciągłości\nMetoda radiograficzna PN-EN ISO 5579:2014-02 Wyroby i materialy metalowe Nieciaglosci\nMetoda radiograficzna PN-EN ISO 5579:2014-02","categories":["materials"],"row_index":294,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Discontinuities","search_en":"Metal products and materials Discontinuities Radiographic method PN-EN ISO 5579:2014-02","technique_en":"Radiographic method","test_object_en":"Metal products and materials","search_zh":"金属制品与材料 不连续性 射线检测法 PN-EN ISO 5579:2014-02","test_object_zh":"金属制品与材料","methodology_zh":"不连续性","technique_zh":"射线检测法"},{"_id":"6a8369ecaf14b9c0e7b1dd49","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Złącza spawane wyrobów","methodology":"Nieciągłości","parameters":[],"technique":"Metoda radiograficzna","techniques":["Metoda radiograficzna"],"computed":[],"activity":"Nieciągłości\nMetoda radiograficzna","reference":"PN-EN ISO 17636-1:2023-02","norm_bases":["PN-EN ISO 17636-1:2023-02"],"lab_section":"Pracownia Badań Nieniszczących","lab_address":null,"regulatory_area":"Potwierdzono kompetencje personelu do formułowania opinii i interpretacji na podstawie wyników badań wykonywanych w ww. Pracowni.","flexible":false,"search_text":"Złącza spawane wyrobów Nieciągłości\nMetoda radiograficzna PN-EN ISO 17636-1:2023-02 Zlacza spawane wyrobow Nieciaglosci\nMetoda radiograficzna PN-EN ISO 17636-1:2023-02","categories":["other"],"row_index":295,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Discontinuities","search_en":"Discontinuities Radiographic method PN-EN ISO 17636-1:2023-02","technique_en":"Radiographic method","methodology_zh":"不连续性","search_zh":"不连续性 射线检测法 PN-EN ISO 17636-1:2023-02","technique_zh":"射线检测法"},{"_id":"6a8369ecaf14b9c0e7b1dd4a","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Rury stalowe","methodology":"Nieciągłości","parameters":[],"technique":"Metoda radiograficzna","techniques":["Metoda radiograficzna"],"computed":[],"activity":"Nieciągłości\nMetoda radiograficzna","reference":"PN-EN ISO 10893-6:2019-04","norm_bases":["PN-EN ISO 10893-6:2019-04"],"lab_section":"Pracownia Badań Nieniszczących","lab_address":null,"regulatory_area":"Potwierdzono kompetencje personelu do formułowania opinii i interpretacji na podstawie wyników badań wykonywanych w ww. Pracowni.","flexible":false,"search_text":"Rury stalowe Nieciągłości\nMetoda radiograficzna PN-EN ISO 10893-6:2019-04 Rury stalowe Nieciaglosci\nMetoda radiograficzna PN-EN ISO 10893-6:2019-04","categories":["materials"],"row_index":296,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Discontinuities","search_en":"Steel pipes Discontinuities Radiographic method PN-EN ISO 10893-6:2019-04","technique_en":"Radiographic method","test_object_en":"Steel pipes","methodology_zh":"不连续性","search_zh":"钢管 不连续性 射线检测法 PN-EN ISO 10893-6:2019-04","technique_zh":"射线检测法","test_object_zh":"钢管"},{"_id":"6a8369ecaf14b9c0e7b1dd4b","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Odlewy","methodology":"Nieciągłości","parameters":[],"technique":"Metoda radiograficzna","techniques":["Metoda radiograficzna"],"computed":[],"activity":"Nieciągłości\nMetoda radiograficzna","reference":"PN-EN 12681:2018-01","norm_bases":["PN-EN 12681:2018-01"],"lab_section":"Pracownia Badań Nieniszczących","lab_address":null,"regulatory_area":"Potwierdzono kompetencje personelu do formułowania opinii i interpretacji na podstawie wyników badań wykonywanych w ww. Pracowni.","flexible":false,"search_text":"Odlewy Nieciągłości\nMetoda radiograficzna PN-EN 12681:2018-01 Odlewy Nieciaglosci\nMetoda radiograficzna PN-EN 12681:2018-01","categories":["other"],"row_index":297,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Discontinuities","search_en":"Castings Discontinuities Radiographic method PN-EN 12681:2018-01","technique_en":"Radiographic method","test_object_en":"Castings","methodology_zh":"不连续性","search_zh":"铸件 不连续性 射线检测法 PN-EN 12681:2018-01","technique_zh":"射线检测法","test_object_zh":"铸件"},{"_id":"6a8369ecaf14b9c0e7b1dd4c","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Złącza spawane wyrobów","methodology":"Nieciągłości","parameters":[],"technique":"Metoda radiograficzna z użyciem detektorów cyfrowych","techniques":["Metoda radiograficzna z użyciem detektorów cyfrowych"],"computed":[],"activity":"Nieciągłości\nMetoda radiograficzna z użyciem detektorów cyfrowych","reference":"PN-EN ISO 17636-2:2023-04","norm_bases":["PN-EN ISO 17636-2:2023-04"],"lab_section":"Pracownia Badań Nieniszczących","lab_address":null,"regulatory_area":"Potwierdzono kompetencje personelu do formułowania opinii i interpretacji na podstawie wyników badań wykonywanych w ww. Pracowni.","flexible":false,"search_text":"Złącza spawane wyrobów Nieciągłości\nMetoda radiograficzna z użyciem detektorów cyfrowych PN-EN ISO 17636-2:2023-04 Zlacza spawane wyrobow Nieciaglosci\nMetoda radiograficzna z uzyciem detektorow cyfrowych PN-EN ISO 17636-2:2023-04","categories":["other"],"row_index":298,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Discontinuities","search_en":"Discontinuities Radiographic method using digital detectors PN-EN ISO 17636-2:2023-04","technique_en":"Radiographic method using digital detectors","methodology_zh":"不连续性","search_zh":"不连续性 使用数字探测器的射线照相法 PN-EN ISO 17636-2:2023-04","technique_zh":"使用数字探测器的射线照相法"},{"_id":"6a8369ecaf14b9c0e7b1dd4d","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Odlewy","methodology":"Nieciągłości","parameters":[],"technique":"Metoda radiograficzna z użyciem detektorów cyfrowych","techniques":["Metoda radiograficzna z użyciem detektorów cyfrowych"],"computed":[],"activity":"Nieciągłości\nMetoda radiograficzna z użyciem detektorów cyfrowych","reference":"PN-EN 12681-2:2017-12","norm_bases":["PN-EN 12681-2:2017-12"],"lab_section":"Pracownia Badań Nieniszczących","lab_address":null,"regulatory_area":"Potwierdzono kompetencje personelu do formułowania opinii i interpretacji na podstawie wyników badań wykonywanych w ww. Pracowni.","flexible":false,"search_text":"Odlewy Nieciągłości\nMetoda radiograficzna z użyciem detektorów cyfrowych PN-EN 12681-2:2017-12 Odlewy Nieciaglosci\nMetoda radiograficzna z uzyciem detektorow cyfrowych PN-EN 12681-2:2017-12","categories":["other"],"row_index":299,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Discontinuities","search_en":"Castings Discontinuities Radiographic method using digital detectors PN-EN 12681-2:2017-12","technique_en":"Radiographic method using digital detectors","test_object_en":"Castings","methodology_zh":"不连续性","search_zh":"铸件 不连续性 使用数字探测器的射线照相法 PN-EN 12681-2:2017-12","test_object_zh":"铸件","technique_zh":"使用数字探测器的射线照相法"},{"_id":"6a8369ecaf14b9c0e7b1dd4e","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Wyroby i materiały metalowe","methodology":"Nieciągłości","parameters":[],"technique":"Metoda ultradźwiękowa","techniques":["Metoda ultradźwiękowa"],"computed":[],"activity":"Nieciągłości\nMetoda ultradźwiękowa","reference":"PN-EN ISO 16810:2025-04","norm_bases":["PN-EN ISO 16810:2025-04"],"lab_section":"Pracownia Badań Nieniszczących","lab_address":null,"regulatory_area":"Potwierdzono kompetencje personelu do formułowania opinii i interpretacji na podstawie wyników badań wykonywanych w ww. Pracowni.","flexible":false,"search_text":"Wyroby i materiały metalowe Nieciągłości\nMetoda ultradźwiękowa PN-EN ISO 16810:2025-04 Wyroby i materialy metalowe Nieciaglosci\nMetoda ultradzwiekowa PN-EN ISO 16810:2025-04","categories":["materials"],"row_index":300,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Discontinuities","search_en":"Metal products and materials Discontinuities Ultrasonic method PN-EN ISO 16810:2025-04","technique_en":"Ultrasonic method","test_object_en":"Metal products and materials","search_zh":"金属制品与材料 不连续性 超声法 PN-EN ISO 16810:2025-04","technique_zh":"超声法","test_object_zh":"金属制品与材料","methodology_zh":"不连续性"},{"_id":"6a8369ecaf14b9c0e7b1dd4f","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Wyroby stalowe płaskie","methodology":"Nieciągłości","parameters":[],"technique":"Metoda ultradźwiękowa","techniques":["Metoda ultradźwiękowa"],"computed":[],"activity":"Nieciągłości\nMetoda ultradźwiękowa","reference":"PN-EN 10160:2001","norm_bases":["PN-EN 10160:2001"],"lab_section":"Pracownia Badań Nieniszczących","lab_address":null,"regulatory_area":"Potwierdzono kompetencje personelu do formułowania opinii i interpretacji na podstawie wyników badań wykonywanych w ww. Pracowni.","flexible":false,"search_text":"Wyroby stalowe płaskie Nieciągłości\nMetoda ultradźwiękowa PN-EN 10160:2001 Wyroby stalowe plaskie Nieciaglosci\nMetoda ultradzwiekowa PN-EN 10160:2001","categories":["materials"],"row_index":301,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Discontinuities","search_en":"Flat steel products Discontinuities Ultrasonic method PN-EN 10160:2001","technique_en":"Ultrasonic method","test_object_en":"Flat steel products","search_zh":"扁平钢材 不连续性 超声法 PN-EN 10160:2001","technique_zh":"超声法","methodology_zh":"不连续性","test_object_zh":"扁平钢材"},{"_id":"6a8369ecaf14b9c0e7b1dd50","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Odkuwki","methodology":"Nieciągłości","parameters":[],"technique":"Metoda ultradźwiękowa","techniques":["Metoda ultradźwiękowa"],"computed":[],"activity":"Nieciągłości\nMetoda ultradźwiękowa","reference":"PN-EN 10228-3:2016-07","norm_bases":["PN-EN 10228-3:2016-07"],"lab_section":"Pracownia Badań Nieniszczących","lab_address":null,"regulatory_area":"Potwierdzono kompetencje personelu do formułowania opinii i interpretacji na podstawie wyników badań wykonywanych w ww. Pracowni.","flexible":false,"search_text":"Odkuwki Nieciągłości\nMetoda ultradźwiękowa PN-EN 10228-3:2016-07 Odkuwki Nieciaglosci\nMetoda ultradzwiekowa PN-EN 10228-3:2016-07","categories":["other"],"row_index":302,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Discontinuities","search_en":"Forgings Discontinuities Ultrasonic method PN-EN 10228-3:2016-07","technique_en":"Ultrasonic method","test_object_en":"Forgings","search_zh":"锻件 不连续性 超声法 PN-EN 10228-3:2016-07","technique_zh":"超声法","methodology_zh":"不连续性","test_object_zh":"锻件"},{"_id":"6a8369ecaf14b9c0e7b1dd51","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Odkuwki","methodology":"Nieciągłości","parameters":[],"technique":"Metoda ultradźwiękowa","techniques":["Metoda ultradźwiękowa"],"computed":[],"activity":"Nieciągłości\nMetoda ultradźwiękowa","reference":"PN-EN 10228-4:2016-07","norm_bases":["PN-EN 10228-4:2016-07"],"lab_section":"Pracownia Badań Nieniszczących","lab_address":null,"regulatory_area":"Potwierdzono kompetencje personelu do formułowania opinii i interpretacji na podstawie wyników badań wykonywanych w ww. Pracowni.","flexible":false,"search_text":"Odkuwki Nieciągłości\nMetoda ultradźwiękowa PN-EN 10228-4:2016-07 Odkuwki Nieciaglosci\nMetoda ultradzwiekowa PN-EN 10228-4:2016-07","categories":["other"],"row_index":303,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Discontinuities","search_en":"Forgings Discontinuities Ultrasonic method PN-EN 10228-4:2016-07","technique_en":"Ultrasonic method","test_object_en":"Forgings","search_zh":"锻件 不连续性 超声法 PN-EN 10228-4:2016-07","technique_zh":"超声法","methodology_zh":"不连续性","test_object_zh":"锻件"},{"_id":"6a8369ecaf14b9c0e7b1dd52","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Złącza spawane materiałów metalowych, Złącza spawane materiałów","methodology":"Nieciągłości","parameters":[],"technique":"Metoda ultradźwiękowa","techniques":["Metoda ultradźwiękowa"],"computed":[],"activity":"Nieciągłości\nMetoda ultradźwiękowa","reference":"PN-EN ISO 17640:2019-01","norm_bases":["PN-EN ISO 17640:2019-01"],"lab_section":"Pracownia Badań Nieniszczących","lab_address":null,"regulatory_area":"Potwierdzono kompetencje personelu do formułowania opinii i interpretacji na podstawie wyników badań wykonywanych w ww. Pracowni.","flexible":false,"search_text":"Złącza spawane materiałów metalowych, Złącza spawane materiałów Nieciągłości\nMetoda ultradźwiękowa PN-EN ISO 17640:2019-01 Zlacza spawane materialow metalowych, Zlacza spawane materialow Nieciaglosci\nMetoda ultradzwiekowa PN-EN ISO 17640:2019-01","categories":["materials"],"row_index":304,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Discontinuities","search_en":"Discontinuities Ultrasonic method PN-EN ISO 17640:2019-01","technique_en":"Ultrasonic method","search_zh":"不连续性 超声法 PN-EN ISO 17640:2019-01","technique_zh":"超声法","methodology_zh":"不连续性"},{"_id":"6a8369ecaf14b9c0e7b1dd53","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"metalowych","methodology":"Nieciągłości","parameters":[],"technique":"Metoda ultradźwiękowa","techniques":["Metoda ultradźwiękowa"],"computed":[],"activity":"Nieciągłości\nMetoda ultradźwiękowa","reference":"PN-EN ISO 16826:2014-06","norm_bases":["PN-EN ISO 16826:2014-06"],"lab_section":"Pracownia Badań Nieniszczących","lab_address":null,"regulatory_area":"Potwierdzono kompetencje personelu do formułowania opinii i interpretacji na podstawie wyników badań wykonywanych w ww. Pracowni.","flexible":false,"search_text":"metalowych Nieciągłości\nMetoda ultradźwiękowa PN-EN ISO 16826:2014-06 metalowych Nieciaglosci\nMetoda ultradzwiekowa PN-EN ISO 16826:2014-06","categories":["materials"],"row_index":305,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Discontinuities","search_en":"Discontinuities Ultrasonic method PN-EN ISO 16826:2014-06","technique_en":"Ultrasonic method","search_zh":"不连续性 超声法 PN-EN ISO 16826:2014-06","technique_zh":"超声法","methodology_zh":"不连续性"},{"_id":"6a8369ecaf14b9c0e7b1dd54","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"metalowych","methodology":"Nieciągłości","parameters":[],"technique":"Metoda ultradźwiękowa","techniques":["Metoda ultradźwiękowa"],"computed":[],"activity":"Nieciągłości\nMetoda ultradźwiękowa","reference":"PN-EN ISO 16826:2025-09","norm_bases":["PN-EN ISO 16826:2025-09"],"lab_section":"Pracownia Badań Nieniszczących","lab_address":null,"regulatory_area":"Potwierdzono kompetencje personelu do formułowania opinii i interpretacji na podstawie wyników badań wykonywanych w ww. Pracowni.","flexible":false,"search_text":"metalowych Nieciągłości\nMetoda ultradźwiękowa PN-EN ISO 16826:2025-09 metalowych Nieciaglosci\nMetoda ultradzwiekowa PN-EN ISO 16826:2025-09","categories":["materials"],"row_index":306,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Discontinuities","search_en":"Discontinuities Ultrasonic method PN-EN ISO 16826:2025-09","technique_en":"Ultrasonic method","search_zh":"不连续性 超声法 PN-EN ISO 16826:2025-09","technique_zh":"超声法","methodology_zh":"不连续性"},{"_id":"6a8369ecaf14b9c0e7b1dd55","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"metalowych","methodology":"Nieciągłości","parameters":[],"technique":"Metoda ultradźwiękowa","techniques":["Metoda ultradźwiękowa"],"computed":[],"activity":"Nieciągłości\nMetoda ultradźwiękowa","reference":"PN-EN ISO 16828:2014-06 | PN-EN ISO 16828:2026-01 | PN-EN ISO 10863:2011 | PN-EN ISO 10863:2020-12 | PN-EN ISO 13588:2019-04 | PN-EN ISO 13588:2013-04","norm_bases":["PN-EN ISO 16828:2014-06","PN-EN ISO 16828:2026-01","PN-EN ISO 10863:2011","PN-EN ISO 10863:2020-12","PN-EN ISO 13588:2019-04","PN-EN ISO 13588:2013-04"],"lab_section":"Pracownia Badań Nieniszczących","lab_address":null,"regulatory_area":"Potwierdzono kompetencje personelu do formułowania opinii i interpretacji na podstawie wyników badań wykonywanych w ww. Pracowni.","flexible":false,"search_text":"metalowych Nieciągłości\nMetoda ultradźwiękowa PN-EN ISO 16828:2014-06 | PN-EN ISO 16828:2026-01 | PN-EN ISO 10863:2011 | PN-EN ISO 10863:2020-12 | PN-EN ISO 13588:2019-04 | PN-EN ISO 13588:2013-04 metalowych Nieciaglosci\nMetoda ultradzwiekowa PN-EN ISO 16828:2014-06 | PN-EN ISO 16828:2026-01 | PN-EN ISO 10863:2011 | PN-EN ISO 10863:2020-12 | PN-EN ISO 13588:2019-04 | PN-EN ISO 13588:2013-04","categories":["materials"],"row_index":307,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Discontinuities","search_en":"Discontinuities Ultrasonic method PN-EN ISO 16828:2014-06 | PN-EN ISO 16828:2026-01 | PN-EN ISO 10863:2011 | PN-EN ISO 10863:2020-12 | PN-EN ISO 13588:2019-04 | PN-EN ISO 13588:2013-04","technique_en":"Ultrasonic method","search_zh":"不连续性 超声法 PN-EN ISO 16828:2014-06 | PN-EN ISO 16828:2026-01 | PN-EN ISO 10863:2011 | PN-EN ISO 10863:2020-12 | PN-EN ISO 13588:2019-04 | PN-EN ISO 13588:2013-04","technique_zh":"超声法","methodology_zh":"不连续性"},{"_id":"6a8369ecaf14b9c0e7b1dd56","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Złącza spawane materiałów","methodology":"Nieciągłości","parameters":[],"technique":"Metoda ultradźwiękowa","techniques":["Metoda ultradźwiękowa"],"computed":[],"activity":"Nieciągłości\nMetoda ultradźwiękowa","reference":"PB-PBN-01 wersja 01 z dnia 16.03.2021 r. | PB-PBN-01 wersja 01 z dnia","norm_bases":["PB-PBN-01 wersja 01 z dnia 16.03.2021 r.","PB-PBN-01 wersja 01 z dnia"],"lab_section":"Pracownia Badań Nieniszczących","lab_address":null,"regulatory_area":"Potwierdzono kompetencje personelu do formułowania opinii i interpretacji na podstawie wyników badań wykonywanych w ww. Pracowni.","flexible":false,"search_text":"Złącza spawane materiałów Nieciągłości\nMetoda ultradźwiękowa PB-PBN-01 wersja 01 z dnia 16.03.2021 r. | PB-PBN-01 wersja 01 z dnia Zlacza spawane materialow Nieciaglosci\nMetoda ultradzwiekowa PB-PBN-01 wersja 01 z dnia 16.03.2021 r. | PB-PBN-01 wersja 01 z dnia","categories":["materials"],"row_index":308,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Discontinuities","search_en":"Discontinuities Ultrasonic method PB-PBN-01 wersja 01 z dnia 16.03.2021 r. | PB-PBN-01 wersja 01 z dnia","technique_en":"Ultrasonic method","search_zh":"不连续性 超声法 PB-PBN-01 wersja 01 z dnia 16.03.2021 r. | PB-PBN-01 wersja 01 z dnia","technique_zh":"超声法","methodology_zh":"不连续性"},{"_id":"6a8369ecaf14b9c0e7b1dd57","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"metalowych o grubości od 3 mm","methodology":"Nieciągłości","parameters":[],"technique":"Metoda ultradźwiękowa","techniques":["Metoda ultradźwiękowa"],"computed":[],"activity":"Nieciągłości\nMetoda ultradźwiękowa","reference":"16.03.2021 r.","norm_bases":["16.03.2021 r."],"lab_section":"Pracownia Badań Nieniszczących","lab_address":null,"regulatory_area":"Potwierdzono kompetencje personelu do formułowania opinii i interpretacji na podstawie wyników badań wykonywanych w ww. Pracowni.","flexible":false,"search_text":"metalowych o grubości od 3 mm Nieciągłości\nMetoda ultradźwiękowa 16.03.2021 r. metalowych o grubosci od 3 mm Nieciaglosci\nMetoda ultradzwiekowa 16.03.2021 r.","categories":["materials"],"row_index":309,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Discontinuities","search_en":"Discontinuities Ultrasonic method 16.03.2021 r.","technique_en":"Ultrasonic method","search_zh":"不连续性 超声法 16.03.2021 r.","technique_zh":"超声法","methodology_zh":"不连续性"},{"_id":"6a8369ecaf14b9c0e7b1dd58","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Rury stalowe","methodology":"Nieciągłości","parameters":[],"technique":"Metoda ultradźwiękowa","techniques":["Metoda ultradźwiękowa"],"computed":[],"activity":"Nieciągłości\nMetoda ultradźwiękowa","reference":"PN-EN ISO 10893-8:2011","norm_bases":["PN-EN ISO 10893-8:2011"],"lab_section":"Pracownia Badań Nieniszczących","lab_address":null,"regulatory_area":"Potwierdzono kompetencje personelu do formułowania opinii i interpretacji na podstawie wyników badań wykonywanych w ww. Pracowni.","flexible":false,"search_text":"Rury stalowe Nieciągłości\nMetoda ultradźwiękowa PN-EN ISO 10893-8:2011 Rury stalowe Nieciaglosci\nMetoda ultradzwiekowa PN-EN ISO 10893-8:2011","categories":["materials"],"row_index":310,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Discontinuities","search_en":"Steel pipes Discontinuities Ultrasonic method PN-EN ISO 10893-8:2011","technique_en":"Ultrasonic method","test_object_en":"Steel pipes","search_zh":"钢管 不连续性 超声法 PN-EN ISO 10893-8:2011","technique_zh":"超声法","methodology_zh":"不连续性","test_object_zh":"钢管"},{"_id":"6a8369ecaf14b9c0e7b1dd59","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Odlewy staliwne o grubości do","methodology":"Nieciągłości","parameters":[],"technique":"Metoda ultradźwiękowa","techniques":["Metoda ultradźwiękowa"],"computed":[],"activity":"Nieciągłości\nMetoda ultradźwiękowa","reference":"PN-EN 12680-1:2005","norm_bases":["PN-EN 12680-1:2005"],"lab_section":"Pracownia Badań Nieniszczących","lab_address":null,"regulatory_area":"Potwierdzono kompetencje personelu do formułowania opinii i interpretacji na podstawie wyników badań wykonywanych w ww. Pracowni.","flexible":false,"search_text":"Odlewy staliwne o grubości do Nieciągłości\nMetoda ultradźwiękowa PN-EN 12680-1:2005 Odlewy staliwne o grubosci do Nieciaglosci\nMetoda ultradzwiekowa PN-EN 12680-1:2005","categories":["other"],"row_index":311,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Discontinuities","search_en":"Discontinuities Ultrasonic method PN-EN 12680-1:2005","technique_en":"Ultrasonic method","search_zh":"不连续性 超声法 PN-EN 12680-1:2005","technique_zh":"超声法","methodology_zh":"不连续性"},{"_id":"6a8369ecaf14b9c0e7b1dd5a","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"600 mm","methodology":"Nieciągłości","parameters":[],"technique":"Metoda ultradźwiękowa","techniques":["Metoda ultradźwiękowa"],"computed":[],"activity":"Nieciągłości\nMetoda ultradźwiękowa","reference":"PN-EN 12680-2:2005","norm_bases":["PN-EN 12680-2:2005"],"lab_section":"Pracownia Badań Nieniszczących","lab_address":null,"regulatory_area":"Potwierdzono kompetencje personelu do formułowania opinii i interpretacji na podstawie wyników badań wykonywanych w ww. Pracowni.","flexible":false,"search_text":"600 mm Nieciągłości\nMetoda ultradźwiękowa PN-EN 12680-2:2005 600 mm Nieciaglosci\nMetoda ultradzwiekowa PN-EN 12680-2:2005","categories":["other"],"row_index":312,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Discontinuities","search_en":"Discontinuities Ultrasonic method PN-EN 12680-2:2005","technique_en":"Ultrasonic method","search_zh":"不连续性 超声法 PN-EN 12680-2:2005","technique_zh":"超声法","methodology_zh":"不连续性"},{"_id":"6a8369ecaf14b9c0e7b1dd5b","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Wyroby z materiałów metalowych","methodology":"Grubość","parameters":[],"technique":"Metoda ultradźwiękowa","techniques":["Metoda ultradźwiękowa"],"computed":[],"activity":"Grubość\nMetoda ultradźwiękowa","reference":"PN-EN ISO 16809:2025-12","norm_bases":["PN-EN ISO 16809:2025-12"],"lab_section":"Pracownia Badań Nieniszczących","lab_address":null,"regulatory_area":"Potwierdzono kompetencje personelu do formułowania opinii i interpretacji na podstawie wyników badań wykonywanych w ww. Pracowni.","flexible":false,"search_text":"Wyroby z materiałów metalowych Grubość\nMetoda ultradźwiękowa PN-EN ISO 16809:2025-12 Wyroby z materialow metalowych Grubosc\nMetoda ultradzwiekowa PN-EN ISO 16809:2025-12","categories":["materials"],"row_index":313,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Thickness","search_en":"Products made of metallic materials Thickness Ultrasonic method PN-EN ISO 16809:2025-12","technique_en":"Ultrasonic method","test_object_en":"Products made of metallic materials","search_zh":"厚度 超声法 PN-EN ISO 16809:2025-12","technique_zh":"超声法","methodology_zh":"厚度"},{"_id":"6a8369ecaf14b9c0e7b1dd5c","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Wyroby i materiały metalowe","methodology":"Twardość","parameters":[],"technique":"Metoda Leeba","techniques":["Metoda Leeba"],"computed":[],"activity":"Twardość\nMetoda Leeba","reference":"PN-EN ISO 16859-1:2015-12","norm_bases":["PN-EN ISO 16859-1:2015-12"],"lab_section":"Pracownia Badań Nieniszczących","lab_address":null,"regulatory_area":"Potwierdzono kompetencje personelu do formułowania opinii i interpretacji na podstawie wyników badań wykonywanych w ww. Pracowni.","flexible":false,"search_text":"Wyroby i materiały metalowe Twardość\nMetoda Leeba PN-EN ISO 16859-1:2015-12 Wyroby i materialy metalowe Twardosc\nMetoda Leeba PN-EN ISO 16859-1:2015-12","categories":["materials"],"row_index":314,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hardness","search_en":"Metal products and materials Hardness Leeb method PN-EN ISO 16859-1:2015-12","technique_en":"Leeb method","test_object_en":"Metal products and materials","search_zh":"金属制品与材料 硬度 里氏法 PN-EN ISO 16859-1:2015-12","test_object_zh":"金属制品与材料","methodology_zh":"硬度","technique_zh":"里氏法"},{"_id":"6a8369ecaf14b9c0e7b1dd5d","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda (w tym, woda na pływalniach), Ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 - 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 - 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym, woda na pływalniach), Ścieki pH\nZakres 4,0 - 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda (w tym, woda na plywalniach), Scieki pH\nZakres 4,0 - 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":315,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 - 10,0"}],"search_en":"Water (including, swimming pool water), Wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water (including, swimming pool water), Wastewater","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 - 10,0"}],"search_zh":"水（含游泳池水）、废水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水（含游泳池水）、废水"},{"_id":"6a8369ecaf14b9c0e7b1dd5e","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda (w tym, woda na pływalniach), Ścieki","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,10 - 1000) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,10 - 1000) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym, woda na pływalniach), Ścieki Mętność\nZakres (0,10 - 1000) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda (w tym, woda na plywalniach), Scieki Metnosc\nZakres (0,10 - 1000) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":316,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,10 - 1000) NTU"}],"search_en":"Water (including, swimming pool water), Wastewater Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09","technique_en":"Nephelometric method","test_object_en":"Water (including, swimming pool water), Wastewater","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,10 - 1000) NTU"}],"search_zh":"水（含游泳池水）、废水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"水（含游泳池水）、废水"},{"_id":"6a8369ecaf14b9c0e7b1dd5f","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda (w tym, woda na pływalniach), Ścieki","methodology":"Indeks nadmanganianowy","parameters":[{"name":"Zakres","range":"(0,50 - 200) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Indeks nadmanganianowy\nZakres (0,50 - 200) mg/l O2\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym, woda na pływalniach), Ścieki Indeks nadmanganianowy\nZakres (0,50 - 200) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda (w tym, woda na plywalniach), Scieki Indeks nadmanganianowy\nZakres (0,50 - 200) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":317,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Permanganate index","parameters_en":[{"name":"Range","range":"(0,50 - 200) mg/l O2"}],"search_en":"Water (including, swimming pool water), Wastewater Permanganate index Titrimetric method Range PN-EN ISO 8467:2001","technique_en":"Titrimetric method","test_object_en":"Water (including, swimming pool water), Wastewater","methodology_zh":"高锰酸盐指数","parameters_zh":[{"name":"范围","range":"(0,50 - 200) mg/l O2"}],"search_zh":"水（含游泳池水）、废水 高锰酸盐指数 滴定法 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"水（含游泳池水）、废水"},{"_id":"6a8369ecaf14b9c0e7b1dd60","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda (w tym, woda na pływalniach), Ścieki","methodology":"Stężenie azotu azotanowego","parameters":[{"name":"Zakres","range":"(0,10 - 1000) mg/l"},{"name":"Stężenie azotanów"},{"name":"Zakres","range":"(0,45 - 4000) mg/l"}],"technique":"Metoda spektrofotometryczna; Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna","Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotanowego\nZakres:\nZakres (0,10 - 1000) mg/l\nStężenie azotanów\nZakres (0,45 - 4000) mg/l\nMetoda spektrofotometryczna; Metoda spektrofotometryczna","reference":"PN-EN ISO 15923-1:2025-02","norm_bases":["PN-EN ISO 15923-1:2025-02"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym, woda na pływalniach), Ścieki Stężenie azotu azotanowego\nZakres:\nZakres (0,10 - 1000) mg/l\nStężenie azotanów\nZakres (0,45 - 4000) mg/l\nMetoda spektrofotometryczna; Metoda spektrofotometryczna PN-EN ISO 15923-1:2025-02 Woda (w tym, woda na plywalniach), Scieki Stezenie azotu azotanowego\nZakres:\nZakres (0,10 - 1000) mg/l\nStezenie azotanow\nZakres (0,45 - 4000) mg/l\nMetoda spektrofotometryczna; Metoda spektrofotometryczna PN-EN ISO 15923-1:2025-02","categories":["water"],"row_index":318,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,10 - 1000) mg/l"},{"name":"Nitrate concentration"},{"name":"Range","range":"(0,45 - 4000) mg/l"}],"search_en":"Water (including, swimming pool water), Wastewater Nitrate nitrogen concentration Spectrophotometric method; Spectrophotometric method Range Nitrate concentration Range PN-EN ISO 15923-1:2025-02","technique_en":"Spectrophotometric method; Spectrophotometric method","test_object_en":"Water (including, swimming pool water), Wastewater","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,10 - 1000) mg/l"},{"name":"硝酸盐浓度"},{"name":"范围","range":"(0,45 - 4000) mg/l"}],"search_zh":"水（含游泳池水）、废水 硝态氮浓度 分光光度法；分光光度法 范围 硝酸盐浓度 范围 PN-EN ISO 15923-1:2025-02","technique_zh":"分光光度法；分光光度法","test_object_zh":"水（含游泳池水）、废水"},{"_id":"6a8369ecaf14b9c0e7b1dd61","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(50,0 - 50000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (50,0 - 50000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Przewodność elektryczna właściwa\nZakres (50,0 - 50000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, Scieki Przewodnosc elektryczna wlasciwa\nZakres (50,0 - 50000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":319,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(50,0 - 50000) μS/cm"}],"search_en":"Water, Wastewater Electrical conductivity Conductometric method Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water, Wastewater","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(50,0 - 50000) μS/cm"}],"search_zh":"水、污水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、污水"},{"_id":"6a8369ecaf14b9c0e7b1dd62","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Zasadowość, wodorowęglany","parameters":[{"name":"zasadowość","range":"(0,40 - 100) mmol/l"},{"name":"wodorowęglany","range":"(25 - 6000) mg/l"}],"technique":"Metoda miareczkowania potencjometrycznego","techniques":["Metoda miareczkowania potencjometrycznego"],"computed":[],"activity":"Zasadowość, wodorowęglany\nZakres:\nzasadowość (0,40 - 100) mmol/l\nwodorowęglany (25 - 6000) mg/l\nMetoda miareczkowania potencjometrycznego","reference":"PN-EN ISO 9963-1:2001+Ap1:2004","norm_bases":["PN-EN ISO 9963-1:2001+Ap1:2004"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Zasadowość, wodorowęglany\nZakres:\nzasadowość (0,40 - 100) mmol/l\nwodorowęglany (25 - 6000) mg/l\nMetoda miareczkowania potencjometrycznego PN-EN ISO 9963-1:2001+Ap1:2004 Woda, Scieki Zasadowosc, wodoroweglany\nZakres:\nzasadowosc (0,40 - 100) mmol/l\nwodoroweglany (25 - 6000) mg/l\nMetoda miareczkowania potencjometrycznego PN-EN ISO 9963-1:2001+Ap1:2004","categories":["water"],"row_index":320,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Alkalinity, hydrogen carbonates","parameters_en":[{"name":"alkalinity","range":"(0,40 - 100) mmol/l"},{"name":"bicarbonates","range":"(25 - 6000) mg/l"}],"search_en":"Water, Wastewater Alkalinity, hydrogen carbonates Potentiometric titration method alkalinity bicarbonates PN-EN ISO 9963-1:2001+Ap1:2004","technique_en":"Potentiometric titration method","test_object_en":"Water, Wastewater","search_zh":"水、污水 电位滴定法 PN-EN ISO 9963-1:2001+Ap1:2004","technique_zh":"电位滴定法","test_object_zh":"水、污水"},{"_id":"6a8369ecaf14b9c0e7b1dd63","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Twardość ogólna","parameters":[{"name":"Zakres","range":"(5,00 - 5000) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Twardość ogólna\nZakres (5,00 - 5000) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Twardość ogólna\nZakres (5,00 - 5000) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999 Woda, Scieki Twardosc ogolna\nZakres (5,00 - 5000) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":321,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total hardness","parameters_en":[{"name":"Range","range":"(5,00 - 5000) mg/l CaCO3"}],"search_en":"Water, Wastewater Total hardness Titrimetric method Range PN-ISO 6059:1999","technique_en":"Titrimetric method","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(5,00 - 5000) mg/l CaCO3"}],"search_zh":"水、污水 总硬度 滴定法 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"水、污水","methodology_zh":"总硬度"},{"_id":"6a8369ecaf14b9c0e7b1dd64","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Indeks fenolowy","parameters":[{"name":"Zakres","range":"(0,002 - 10,0) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Indeks fenolowy\nZakres (0,002 - 10,0) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 14402:2004","norm_bases":["PN-EN ISO 14402:2004"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Indeks fenolowy\nZakres (0,002 - 10,0) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 14402:2004 Woda, Scieki Indeks fenolowy\nZakres (0,002 - 10,0) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 14402:2004","categories":["water"],"row_index":322,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phenol index","parameters_en":[{"name":"Range","range":"(0,002 - 10,0) mg/l"}],"search_en":"Water, Wastewater Phenol index Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN ISO 14402:2004","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(0,002 - 10,0) mg/l"}],"search_zh":"水、污水 酚指数 连续流动分析（CFA）分光光度检测法 范围 PN-EN ISO 14402:2004","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"水、污水","methodology_zh":"酚指数"},{"_id":"6a8369ecaf14b9c0e7b1dd65","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie cyjanków ogólnych, cyjanków wolnych","parameters":[{"name":"Zakres","range":"(15,0 - 10000) μg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie cyjanków ogólnych, cyjanków wolnych\nZakres (15,0 - 10000) μg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 14403-2:2012","norm_bases":["PN-EN ISO 14403-2:2012"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie cyjanków ogólnych, cyjanków wolnych\nZakres (15,0 - 10000) μg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 14403-2:2012 Woda, Scieki Stezenie cyjankow ogolnych, cyjankow wolnych\nZakres (15,0 - 10000) μg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 14403-2:2012","categories":["water"],"row_index":323,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total cyanide, free cyanide concentration","parameters_en":[{"name":"Range","range":"(15,0 - 10000) μg/l"}],"search_en":"Water, Wastewater Total cyanide, free cyanide concentration Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN ISO 14403-2:2012","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(15,0 - 10000) μg/l"}],"search_zh":"水、污水 连续流动分析（CFA）分光光度检测法 范围 PN-EN ISO 14403-2:2012","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"水、污水"},{"_id":"6a8369ecaf14b9c0e7b1dd66","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie cyjanków związanych (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie cyjanków związanych (z obliczeń)","reference":"PN-EN ISO 14403-2:2012","norm_bases":["PN-EN ISO 14403-2:2012"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie cyjanków związanych (z obliczeń) PN-EN ISO 14403-2:2012 Woda, Scieki Stezenie cyjankow zwiazanych (z obliczen) PN-EN ISO 14403-2:2012","categories":["water"],"row_index":324,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Combined cyanide concentration (calculated)","search_en":"Water, Wastewater Combined cyanide concentration (calculated) PN-EN ISO 14403-2:2012","test_object_en":"Water, Wastewater","search_zh":"水、污水 络合氰化物浓度（由计算得出） PN-EN ISO 14403-2:2012","test_object_zh":"水、污水","methodology_zh":"络合氰化物浓度（由计算得出）"},{"_id":"6a8369ecaf14b9c0e7b1dd67","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie azotu ogólnego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PB-DAN-17 wersja 01 z dnia 16.02.2021 r.","norm_bases":["PB-DAN-17 wersja 01 z dnia 16.02.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie azotu ogólnego (z obliczeń) PB-DAN-17 wersja 01 z dnia 16.02.2021 r. Woda, Scieki Stezenie azotu ogolnego (z obliczen) PB-DAN-17 wersja 01 z dnia 16.02.2021 r.","categories":["water"],"row_index":325,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total nitrogen concentration (calculated)","search_en":"Water, Wastewater Total nitrogen concentration (calculated) PB-DAN-17 wersja 01 z dnia 16.02.2021 r.","test_object_en":"Water, Wastewater","methodology_zh":"总氮浓度（计算值）","search_zh":"水、污水 总氮浓度（计算值） PB-DAN-17 wersja 01 z dnia 16.02.2021 r.","test_object_zh":"水、污水"},{"_id":"6a8369ecaf14b9c0e7b1dd68","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie azotu ogólnego","parameters":[{"name":"Zakres","range":"(0,50 - 600) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie azotu ogólnego\nZakres (0,50 - 600) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 11905-1:2001","norm_bases":["PN-EN ISO 11905-1:2001"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie azotu ogólnego\nZakres (0,50 - 600) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 11905-1:2001 Woda, Scieki Stezenie azotu ogolnego\nZakres (0,50 - 600) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 11905-1:2001","categories":["water"],"row_index":326,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,50 - 600) mg/l"}],"search_en":"Water, Wastewater Total nitrogen concentration Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN ISO 11905-1:2001","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Water, Wastewater","methodology_zh":"总氮浓度","parameters_zh":[{"name":"范围","range":"(0,50 - 600) mg/l"}],"search_zh":"水、污水 总氮浓度 连续流动分析（CFA）分光光度检测法 范围 PN-EN ISO 11905-1:2001","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"水、污水"},{"_id":"6a8369ecaf14b9c0e7b1dd69","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie azotu ogólnego","parameters":[{"name":"Zakres","range":"(0,5 - 3000) mg/l"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją chemiluminescencyjną","techniques":["Metoda wysokotemperaturowego spalania z detekcją chemiluminescencyjną"],"computed":[],"activity":"Stężenie azotu ogólnego\nZakres (0,5 - 3000) mg/l\nMetoda wysokotemperaturowego spalania z detekcją chemiluminescencyjną","reference":"PN-EN ISO 20236:2025-05","norm_bases":["PN-EN ISO 20236:2025-05"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie azotu ogólnego\nZakres (0,5 - 3000) mg/l\nMetoda wysokotemperaturowego spalania z detekcją chemiluminescencyjną PN-EN ISO 20236:2025-05 Woda, Scieki Stezenie azotu ogolnego\nZakres (0,5 - 3000) mg/l\nMetoda wysokotemperaturowego spalania z detekcja chemiluminescencyjna PN-EN ISO 20236:2025-05","categories":["water"],"row_index":327,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,5 - 3000) mg/l"}],"search_en":"Water, Wastewater Total nitrogen concentration High-temperature combustion with chemiluminescence detection Range PN-EN ISO 20236:2025-05","technique_en":"High-temperature combustion with chemiluminescence detection","test_object_en":"Water, Wastewater","methodology_zh":"总氮浓度","parameters_zh":[{"name":"范围","range":"(0,5 - 3000) mg/l"}],"search_zh":"水、污水 总氮浓度 高温燃烧-化学发光检测法 范围 PN-EN ISO 20236:2025-05","test_object_zh":"水、污水","technique_zh":"高温燃烧-化学发光检测法"},{"_id":"6a8369ecaf14b9c0e7b1dd6a","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie azotu Kjeldahla (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu Kjeldahla (z obliczeń)","reference":"PN-EN ISO 20236:2025-05","norm_bases":["PN-EN ISO 20236:2025-05"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie azotu Kjeldahla (z obliczeń) PN-EN ISO 20236:2025-05 Woda, Scieki Stezenie azotu Kjeldahla (z obliczen) PN-EN ISO 20236:2025-05","categories":["water"],"row_index":328,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen concentration (calculated)","search_en":"Water, Wastewater Kjeldahl nitrogen concentration (calculated) PN-EN ISO 20236:2025-05","test_object_en":"Water, Wastewater","search_zh":"水、污水 PN-EN ISO 20236:2025-05","test_object_zh":"水、污水"},{"_id":"6a8369ecaf14b9c0e7b1dd6b","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie azotu organicznego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu organicznego (z obliczeń)","reference":"PB-DAN-15 wersja 01 z dnia 16 02.2021 r.","norm_bases":["PB-DAN-15 wersja 01 z dnia 16 02.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie azotu organicznego (z obliczeń) PB-DAN-15 wersja 01 z dnia 16 02.2021 r. Woda, Scieki Stezenie azotu organicznego (z obliczen) PB-DAN-15 wersja 01 z dnia 16 02.2021 r.","categories":["water"],"row_index":329,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Organic nitrogen concentration (calculated)","search_en":"Water, Wastewater Organic nitrogen concentration (calculated) PB-DAN-15 wersja 01 z dnia 16 02.2021 r.","test_object_en":"Water, Wastewater","search_zh":"水、污水 有机氮浓度（由计算得出） PB-DAN-15 wersja 01 z dnia 16 02.2021 r.","test_object_zh":"水、污水","methodology_zh":"有机氮浓度（由计算得出）"},{"_id":"6a8369ecaf14b9c0e7b1dd6c","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Substancje powierzchniowo czynne (SPC) niejonowe","parameters":[{"name":"Zakres","range":"(0,2 - 100) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Substancje powierzchniowo czynne (SPC) niejonowe\nZakres (0,2 - 100) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PB-DAN-18 wersja 01 z dnia 16.02.2021 r.","norm_bases":["PB-DAN-18 wersja 01 z dnia 16.02.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Substancje powierzchniowo czynne (SPC) niejonowe\nZakres (0,2 - 100) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PB-DAN-18 wersja 01 z dnia 16.02.2021 r. Woda, Scieki Substancje powierzchniowo czynne (SPC) niejonowe\nZakres (0,2 - 100) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PB-DAN-18 wersja 01 z dnia 16.02.2021 r.","categories":["water"],"row_index":330,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Non-ionic surface-active substances (SPC)","parameters_en":[{"name":"Range","range":"(0,2 - 100) mg/l"}],"search_en":"Water, Wastewater Non-ionic surface-active substances (SPC) Continuous flow analysis (CFA) with spectrophotometric detection Range PB-DAN-18 wersja 01 z dnia 16.02.2021 r.","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(0,2 - 100) mg/l"}],"search_zh":"水、污水 连续流动分析（CFA）分光光度检测法 范围 PB-DAN-18 wersja 01 z dnia 16.02.2021 r.","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"水、污水"},{"_id":"6a8369ecaf14b9c0e7b1dd6d","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Substancje powierzchniowo czynne (SPC) anionowe","parameters":[{"name":"Zakres","range":"(0,05 - 50) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Substancje powierzchniowo czynne (SPC) anionowe\nZakres (0,05 - 50) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 16265:2012","norm_bases":["PN-EN ISO 16265:2012"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Substancje powierzchniowo czynne (SPC) anionowe\nZakres (0,05 - 50) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 16265:2012 Woda, Scieki Substancje powierzchniowo czynne (SPC) anionowe\nZakres (0,05 - 50) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 16265:2012","categories":["water"],"row_index":331,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Anionic surface-active substances (SPC)","parameters_en":[{"name":"Range","range":"(0,05 - 50) mg/l"}],"search_en":"Water, Wastewater Anionic surface-active substances (SPC) Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN ISO 16265:2012","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(0,05 - 50) mg/l"}],"search_zh":"水、污水 连续流动分析（CFA）分光光度检测法 范围 PN-EN ISO 16265:2012","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"水、污水"},{"_id":"6a8369ecaf14b9c0e7b1dd6e","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie ortofosforanów","parameters":[{"name":"Zakres","range":"(0,40 - 400) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie ortofosforanów\nZakres (0,40 - 400) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 15681-2:2019-02","norm_bases":["PN-EN ISO 15681-2:2019-02"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie ortofosforanów\nZakres (0,40 - 400) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 15681-2:2019-02 Woda, Scieki Stezenie ortofosforanow\nZakres (0,40 - 400) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 15681-2:2019-02","categories":["water"],"row_index":332,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Orthophosphate concentration","parameters_en":[{"name":"Range","range":"(0,40 - 400) mg/l"}],"search_en":"Water, Wastewater Orthophosphate concentration Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN ISO 15681-2:2019-02","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(0,40 - 400) mg/l"}],"search_zh":"水、污水 正磷酸盐浓度 连续流动分析（CFA）分光光度检测法 范围 PN-EN ISO 15681-2:2019-02","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"水、污水","methodology_zh":"正磷酸盐浓度"},{"_id":"6a8369ecaf14b9c0e7b1dd6f","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,10 - 100) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,10 - 100) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 15681-2:2019-02","norm_bases":["PN-EN ISO 15681-2:2019-02"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie fosforu ogólnego\nZakres (0,10 - 100) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 15681-2:2019-02 Woda, Scieki Stezenie fosforu ogolnego\nZakres (0,10 - 100) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 15681-2:2019-02","categories":["water"],"row_index":333,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,10 - 100) mg/l"}],"search_en":"Water, Wastewater Total phosphorus concentration Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN ISO 15681-2:2019-02","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Water, Wastewater","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,10 - 100) mg/l"}],"search_zh":"水、污水 总磷浓度 连续流动分析（CFA）分光光度检测法 范围 PN-EN ISO 15681-2:2019-02","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"水、污水"},{"_id":"6a8369ecaf14b9c0e7b1dd70","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie chromu Cr (III) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie chromu Cr (III) (z obliczeń)","reference":"PB-DAN-20 wersja 01 z dnia 16.02.2021 r.","norm_bases":["PB-DAN-20 wersja 01 z dnia 16.02.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie chromu Cr (III) (z obliczeń) PB-DAN-20 wersja 01 z dnia 16.02.2021 r. Woda, Scieki Stezenie chromu Cr (III) (z obliczen) PB-DAN-20 wersja 01 z dnia 16.02.2021 r.","categories":["water"],"row_index":334,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chromium Cr (III) concentration (calculated)","search_en":"Water, Wastewater Chromium Cr (III) concentration (calculated) PB-DAN-20 wersja 01 z dnia 16.02.2021 r.","test_object_en":"Water, Wastewater","search_zh":"水、污水 PB-DAN-20 wersja 01 z dnia 16.02.2021 r.","test_object_zh":"水、污水"},{"_id":"6a8369ecaf14b9c0e7b1dd71","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie chromu Cr (VI)","parameters":[{"name":"Zakres","range":"(0,010 - 10) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie chromu Cr (VI)\nZakres (0,010 - 10) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 23913:2009","norm_bases":["PN-EN ISO 23913:2009"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie chromu Cr (VI)\nZakres (0,010 - 10) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 23913:2009 Woda, Scieki Stezenie chromu Cr (VI)\nZakres (0,010 - 10) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 23913:2009","categories":["water"],"row_index":335,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chromium Cr (VI) concentration","parameters_en":[{"name":"Range","range":"(0,010 - 10) mg/l"}],"search_en":"Water, Wastewater Chromium Cr (VI) concentration Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN ISO 23913:2009","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(0,010 - 10) mg/l"}],"search_zh":"水、污水 连续流动分析（CFA）分光光度检测法 范围 PN-EN ISO 23913:2009","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"水、污水"},{"_id":"6a8369ecaf14b9c0e7b1dd72","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Chemiczne zapotrzebowanie tlenu – ChZT-Cr","parameters":[{"name":"Zakres","range":"(5,0 - 50000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu – ChZT-Cr\nZakres (5,0 - 50000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Chemiczne zapotrzebowanie tlenu – ChZT-Cr\nZakres (5,0 - 50000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda, Scieki Chemiczne zapotrzebowanie tlenu – ChZT-Cr\nZakres (5,0 - 50000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":336,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand – COD-Cr","parameters_en":[{"name":"Range","range":"(5,0 - 50000) mg/l O2"}],"search_en":"Water, Wastewater Chemical oxygen demand – COD-Cr Spectrophotometric method Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(5,0 - 50000) mg/l O2"}],"search_zh":"水、污水 化学需氧量（COD-Cr） 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水、污水","methodology_zh":"化学需氧量（COD-Cr）"},{"_id":"6a8369ecaf14b9c0e7b1dd73","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0 - 5000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0 - 5000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Zawiesiny ogólne\nZakres (2,0 - 5000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, Scieki Zawiesiny ogolne\nZakres (2,0 - 5000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":337,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2,0 - 5000) mg/l"}],"search_en":"Water, Wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Water, Wastewater","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 - 5000) mg/l"}],"search_zh":"水、污水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"水、污水"},{"_id":"6a8369ecaf14b9c0e7b1dd74","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie ogólnego węgla","parameters":[{"name":"organicznego (OWO), rozpuszczonego węgla organicznego (RWO)"},{"name":"Zakres","range":"(1,0 - 5000) mg/l C"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Stężenie ogólnego węgla\nZakres:\norganicznego (OWO), rozpuszczonego węgla organicznego (RWO)\nZakres (1,0 - 5000) mg/l C\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN 1484:1999","norm_bases":["PN-EN 1484:1999"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie ogólnego węgla\nZakres:\norganicznego (OWO), rozpuszczonego węgla organicznego (RWO)\nZakres (1,0 - 5000) mg/l C\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN 1484:1999 Woda, Scieki Stezenie ogolnego wegla\nZakres:\norganicznego (OWO), rozpuszczonego wegla organicznego (RWO)\nZakres (1,0 - 5000) mg/l C\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN 1484:1999","categories":["water"],"row_index":338,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total carbon concentration","parameters_en":[{"name":"organic (TOC), dissolved organic carbon (DOC)"},{"name":"Range","range":"(1,0 - 5000) mg/l C"}],"search_en":"Water, Wastewater Total carbon concentration High-temperature combustion with IR detection organic (TOC), dissolved organic carbon (DOC) Range PN-EN 1484:1999","technique_en":"High-temperature combustion with IR detection","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"organicznego (OWO), rozpuszczonego węgla organicznego (RWO)"},{"name":"范围","range":"(1,0 - 5000) mg/l C"}],"search_zh":"水、污水 总碳浓度 高温燃烧红外检测法 范围 PN-EN 1484:1999","technique_zh":"高温燃烧红外检测法","test_object_zh":"水、污水","methodology_zh":"总碳浓度"},{"_id":"6a8369ecaf14b9c0e7b1dd75","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu – BZT5","parameters":[{"name":"Zakres","range":"(3,0 - 6000) mg/l O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (3,0 - 6000) mg/l O2\nMetoda optyczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (3,0 - 6000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12 Woda, Scieki Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (3,0 - 6000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":339,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand – BOD5","parameters_en":[{"name":"Range","range":"(3,0 - 6000) mg/l O2"}],"search_en":"Water, Wastewater Biochemical oxygen demand – BOD5 Optical method Range PN-EN ISO 5815-1:2019-12","technique_en":"Optical method","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(3,0 - 6000) mg/l O2"}],"search_zh":"水、污水 五日生化需氧量（BOD5） 光学法 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"光学法","test_object_zh":"水、污水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a8369ecaf14b9c0e7b1dd76","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu – BZT5","parameters":[{"name":"Zakres","range":"(0,50 - 6,0) mg/l O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (0,50 - 6,0) mg/l O2\nMetoda optyczna","reference":"PN-EN 1899-2:2002 z wyłączeniem p. 7.2 | PB-DAN-12 wersja 01 z dnia 16.02.2021 r.","norm_bases":["PN-EN 1899-2:2002 z wyłączeniem p. 7.2","PB-DAN-12 wersja 01 z dnia 16.02.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (0,50 - 6,0) mg/l O2\nMetoda optyczna PN-EN 1899-2:2002 z wyłączeniem p. 7.2 | PB-DAN-12 wersja 01 z dnia 16.02.2021 r. Woda, Scieki Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (0,50 - 6,0) mg/l O2\nMetoda optyczna PN-EN 1899-2:2002 z wylaczeniem p. 7.2 | PB-DAN-12 wersja 01 z dnia 16.02.2021 r.","categories":["water"],"row_index":340,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand – BOD5","parameters_en":[{"name":"Range","range":"(0,50 - 6,0) mg/l O2"}],"search_en":"Water, Wastewater Biochemical oxygen demand – BOD5 Optical method Range PN-EN 1899-2:2002 z wyłączeniem p. 7.2 | PB-DAN-12 wersja 01 z dnia 16.02.2021 r.","technique_en":"Optical method","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(0,50 - 6,0) mg/l O2"}],"search_zh":"水、污水 五日生化需氧量（BOD5） 光学法 范围 PN-EN 1899-2:2002 z wyłączeniem p. 7.2 | PB-DAN-12 wersja 01 z dnia 16.02.2021 r.","technique_zh":"光学法","test_object_zh":"水、污水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a8369ecaf14b9c0e7b1dd77","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Substancje rozpuszczone","parameters":[{"name":"Zakres","range":"(3,00 - 100000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Substancje rozpuszczone\nZakres (3,00 - 100000) mg/l\nMetoda wagowa","reference":"APHA Standard Metod 2540 C:1999","norm_bases":["APHA Standard Metod 2540 C:1999"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Substancje rozpuszczone\nZakres (3,00 - 100000) mg/l\nMetoda wagowa APHA Standard Metod 2540 C:1999 Woda, Scieki Substancje rozpuszczone\nZakres (3,00 - 100000) mg/l\nMetoda wagowa APHA Standard Metod 2540 C:1999","categories":["water"],"row_index":341,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissolved solids","parameters_en":[{"name":"Range","range":"(3,00 - 100000) mg/l"}],"search_en":"Water, Wastewater Dissolved solids Gravimetric method Range APHA Standard Metod 2540 C:1999","technique_en":"Gravimetric method","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(3,00 - 100000) mg/l"}],"search_zh":"水、污水 溶解性固体 重量法 范围 APHA Standard Metod 2540 C:1999","technique_zh":"重量法","test_object_zh":"水、污水","methodology_zh":"溶解性固体"},{"_id":"6a8369ecaf14b9c0e7b1dd78","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Substancje organiczne ekstrahujące się eterem naftowym","parameters":[{"name":"Zakres","range":"(0,50 - 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Substancje organiczne ekstrahujące się eterem naftowym\nZakres (0,50 - 1000) mg/l\nMetoda wagowa","reference":"PB-DAN-23 wersja 01 Z dnia 16.02.2021 r.","norm_bases":["PB-DAN-23 wersja 01 Z dnia 16.02.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Substancje organiczne ekstrahujące się eterem naftowym\nZakres (0,50 - 1000) mg/l\nMetoda wagowa PB-DAN-23 wersja 01 Z dnia 16.02.2021 r. Woda, Scieki Substancje organiczne ekstrahujace sie eterem naftowym\nZakres (0,50 - 1000) mg/l\nMetoda wagowa PB-DAN-23 wersja 01 Z dnia 16.02.2021 r.","categories":["water"],"row_index":342,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Organic substances extractable with petroleum ether","parameters_en":[{"name":"Range","range":"(0,50 - 1000) mg/l"}],"search_en":"Water, Wastewater Organic substances extractable with petroleum ether Gravimetric method Range PB-DAN-23 wersja 01 Z dnia 16.02.2021 r.","technique_en":"Gravimetric method","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(0,50 - 1000) mg/l"}],"search_zh":"水、污水 石油醚可萃取有机物质 重量法 范围 PB-DAN-23 wersja 01 Z dnia 16.02.2021 r.","technique_zh":"重量法","test_object_zh":"水、污水","methodology_zh":"石油醚可萃取有机物质"},{"_id":"6a8369ecaf14b9c0e7b1dd79","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Sucha pozostałość","parameters":[{"name":"Zakres","range":"(3,00 - 50000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha pozostałość\nZakres (3,00 - 50000) mg/l\nMetoda wagowa","reference":"PB-DAN-14 wersja 01 z dnia 16.02.2021 r.","norm_bases":["PB-DAN-14 wersja 01 z dnia 16.02.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Sucha pozostałość\nZakres (3,00 - 50000) mg/l\nMetoda wagowa PB-DAN-14 wersja 01 z dnia 16.02.2021 r. Woda, Scieki Sucha pozostalosc\nZakres (3,00 - 50000) mg/l\nMetoda wagowa PB-DAN-14 wersja 01 z dnia 16.02.2021 r.","categories":["water"],"row_index":343,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry residue","parameters_en":[{"name":"Range","range":"(3,00 - 50000) mg/l"}],"search_en":"Water, Wastewater Dry residue Gravimetric method Range PB-DAN-14 wersja 01 z dnia 16.02.2021 r.","technique_en":"Gravimetric method","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(3,00 - 50000) mg/l"}],"search_zh":"水、污水 干残渣 重量法 范围 PB-DAN-14 wersja 01 z dnia 16.02.2021 r.","technique_zh":"重量法","test_object_zh":"水、污水","methodology_zh":"干残渣"},{"_id":"6a8369ecaf14b9c0e7b1dd7a","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie krzemionki","parameters":[{"name":"Zakres","range":"(2,00 - 200) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie krzemionki\nZakres (2,00 - 200) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 15923-1:2025-02","norm_bases":["PN-EN ISO 15923-1:2025-02"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie krzemionki\nZakres (2,00 - 200) mg/l\nMetoda spektrofotometryczna PN-EN ISO 15923-1:2025-02 Woda, Scieki Stezenie krzemionki\nZakres (2,00 - 200) mg/l\nMetoda spektrofotometryczna PN-EN ISO 15923-1:2025-02","categories":["water"],"row_index":344,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Silica concentration","parameters_en":[{"name":"Range","range":"(2,00 - 200) mg/l"}],"search_en":"Water, Wastewater Silica concentration Spectrophotometric method Range PN-EN ISO 15923-1:2025-02","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(2,00 - 200) mg/l"}],"search_zh":"水、污水 二氧化硅浓度 分光光度法 范围 PN-EN ISO 15923-1:2025-02","technique_zh":"分光光度法","test_object_zh":"水、污水","methodology_zh":"二氧化硅浓度"},{"_id":"6a8369ecaf14b9c0e7b1dd7b","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Zawiesina łatwo opadająca","parameters":[{"name":"Zakres","range":"(0,1 - 100) ml/l"}],"technique":"Metoda objętościowa","techniques":["Metoda objętościowa"],"computed":[],"activity":"Zawiesina łatwo opadająca\nZakres (0,1 - 100) ml/l\nMetoda objętościowa","reference":"PB-DAN-16 wersja 01 z dnia 16.02.2021 r.","norm_bases":["PB-DAN-16 wersja 01 z dnia 16.02.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Zawiesina łatwo opadająca\nZakres (0,1 - 100) ml/l\nMetoda objętościowa PB-DAN-16 wersja 01 z dnia 16.02.2021 r. Woda, Scieki Zawiesina latwo opadajaca\nZakres (0,1 - 100) ml/l\nMetoda objetosciowa PB-DAN-16 wersja 01 z dnia 16.02.2021 r.","categories":["water"],"row_index":345,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Settleable solids","parameters_en":[{"name":"Range","range":"(0,1 - 100) ml/l"}],"search_en":"Water, Wastewater Settleable solids Volumetric method Range PB-DAN-16 wersja 01 z dnia 16.02.2021 r.","technique_en":"Volumetric method","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(0,1 - 100) ml/l"}],"search_zh":"水、污水 容量法 范围 PB-DAN-16 wersja 01 z dnia 16.02.2021 r.","test_object_zh":"水、污水","technique_zh":"容量法"},{"_id":"6a8369ecaf14b9c0e7b1dd7c","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Kwasowość","parameters":[{"name":"zakres","range":"(0,10 - 100) mmol/l"}],"technique":"Metoda miareczkowania potencjometrycznego","techniques":["Metoda miareczkowania potencjometrycznego"],"computed":[],"activity":"Kwasowość\nzakres (0,10 - 100) mmol/l\nMetoda miareczkowania potencjometrycznego","reference":"PN-90/C-04540/02+Az:2003","norm_bases":["PN-90/C-04540/02+Az:2003"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Kwasowość\nzakres (0,10 - 100) mmol/l\nMetoda miareczkowania potencjometrycznego PN-90/C-04540/02+Az:2003 Woda, Scieki Kwasowosc\nzakres (0,10 - 100) mmol/l\nMetoda miareczkowania potencjometrycznego PN-90/C-04540/02+Az:2003","categories":["water"],"row_index":346,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Acidity","parameters_en":[{"name":"range","range":"(0,10 - 100) mmol/l"}],"search_en":"Water, Wastewater Acidity Potentiometric titration method range PN-90/C-04540/02+Az:2003","technique_en":"Potentiometric titration method","test_object_en":"Water, Wastewater","methodology_zh":"酸度","search_zh":"水、污水 酸度 电位滴定法 范围 PN-90/C-04540/02+Az:2003","technique_zh":"电位滴定法","test_object_zh":"水、污水","parameters_zh":[{"name":"范围","range":"(0,10 - 100) mmol/l"}]},{"_id":"6a8369ecaf14b9c0e7b1dd7d","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie dwutlenku węgla wolnego","parameters":[{"name":"Zakres","range":"(2,2 - 220) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie dwutlenku węgla wolnego\nZakres (2,2 - 220) mg/l\nMetoda miareczkowa","reference":"PN-74/C-04547/01 | PN-74/C-04547/03","norm_bases":["PN-74/C-04547/01","PN-74/C-04547/03"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie dwutlenku węgla wolnego\nZakres (2,2 - 220) mg/l\nMetoda miareczkowa PN-74/C-04547/01 | PN-74/C-04547/03 Woda, Scieki Stezenie dwutlenku wegla wolnego\nZakres (2,2 - 220) mg/l\nMetoda miareczkowa PN-74/C-04547/01 | PN-74/C-04547/03","categories":["water"],"row_index":347,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free carbon dioxide concentration","parameters_en":[{"name":"Range","range":"(2,2 - 220) mg/l"}],"search_en":"Water, Wastewater Free carbon dioxide concentration Titrimetric method Range PN-74/C-04547/01 | PN-74/C-04547/03","technique_en":"Titrimetric method","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(2,2 - 220) mg/l"}],"search_zh":"水、污水 滴定法 范围 PN-74/C-04547/01 | PN-74/C-04547/03","technique_zh":"滴定法","test_object_zh":"水、污水"},{"_id":"6a8369ecaf14b9c0e7b1dd7e","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie dwutlenku węgla agresywnego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie dwutlenku węgla agresywnego (z obliczeń)","reference":"PN-74/C-04547/01 | PN-74/C-04547/03","norm_bases":["PN-74/C-04547/01","PN-74/C-04547/03"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie dwutlenku węgla agresywnego (z obliczeń) PN-74/C-04547/01 | PN-74/C-04547/03 Woda, Scieki Stezenie dwutlenku wegla agresywnego (z obliczen) PN-74/C-04547/01 | PN-74/C-04547/03","categories":["water"],"row_index":348,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Aggressive carbon dioxide concentration (calculated)","search_en":"Water, Wastewater Aggressive carbon dioxide concentration (calculated) PN-74/C-04547/01 | PN-74/C-04547/03","test_object_en":"Water, Wastewater","search_zh":"水、污水 PN-74/C-04547/01 | PN-74/C-04547/03","test_object_zh":"水、污水"},{"_id":"6a8369ecaf14b9c0e7b1dd7f","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(2,50 - 6000) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie chlorków\nZakres (2,50 - 6000) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 15682:2004","norm_bases":["PN-EN ISO 15682:2004"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie chlorków\nZakres (2,50 - 6000) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 15682:2004 Woda, Scieki Stezenie chlorkow\nZakres (2,50 - 6000) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 15682:2004","categories":["water"],"row_index":349,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(2,50 - 6000) mg/l"}],"search_en":"Water, Wastewater Chloride concentration Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN ISO 15682:2004","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Water, Wastewater","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(2,50 - 6000) mg/l"}],"search_zh":"水、污水 氯化物浓度 连续流动分析（CFA）分光光度检测法 范围 PN-EN ISO 15682:2004","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"水、污水"},{"_id":"6a8369ecaf14b9c0e7b1dd80","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie fluorków","parameters":[{"name":"Zakres","range":"(0,50 - 500) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie fluorków\nZakres (0,50 - 500) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PB-DAN-22 wersja 01 z dnia 16.02.2021 r.","norm_bases":["PB-DAN-22 wersja 01 z dnia 16.02.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie fluorków\nZakres (0,50 - 500) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PB-DAN-22 wersja 01 z dnia 16.02.2021 r. Woda, Scieki Stezenie fluorkow\nZakres (0,50 - 500) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PB-DAN-22 wersja 01 z dnia 16.02.2021 r.","categories":["water"],"row_index":350,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fluoride concentration","parameters_en":[{"name":"Range","range":"(0,50 - 500) mg/l"}],"search_en":"Water, Wastewater Fluoride concentration Continuous flow analysis (CFA) with spectrophotometric detection Range PB-DAN-22 wersja 01 z dnia 16.02.2021 r.","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(0,50 - 500) mg/l"}],"search_zh":"水、污水 氟化物浓度 连续流动分析（CFA）分光光度检测法 范围 PB-DAN-22 wersja 01 z dnia 16.02.2021 r.","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"水、污水","methodology_zh":"氟化物浓度"},{"_id":"6a8369ecaf14b9c0e7b1dd81","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(5,00 - 10000) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie siarczanów\nZakres (5,00 - 10000) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"ISO 22743:2006","norm_bases":["ISO 22743:2006"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie siarczanów\nZakres (5,00 - 10000) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną ISO 22743:2006 Woda, Scieki Stezenie siarczanow\nZakres (5,00 - 10000) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna ISO 22743:2006","categories":["water"],"row_index":351,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Range","range":"(5,00 - 10000) mg/l"}],"search_en":"Water, Wastewater Sulfate concentration Continuous flow analysis (CFA) with spectrophotometric detection Range ISO 22743:2006","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Water, Wastewater","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(5,00 - 10000) mg/l"}],"search_zh":"水、污水 硫酸盐浓度 连续流动分析（CFA）分光光度检测法 范围 ISO 22743:2006","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"水、污水"},{"_id":"6a8369ecaf14b9c0e7b1dd82","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(2,00 - 2000) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chlorków\nZakres (2,00 - 2000) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 15923-1:2025-02","norm_bases":["PN-EN ISO 15923-1:2025-02"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie chlorków\nZakres (2,00 - 2000) mg/l\nMetoda spektrofotometryczna PN-EN ISO 15923-1:2025-02 Woda, Scieki Stezenie chlorkow\nZakres (2,00 - 2000) mg/l\nMetoda spektrofotometryczna PN-EN ISO 15923-1:2025-02","categories":["water"],"row_index":352,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(2,00 - 2000) mg/l"}],"search_en":"Water, Wastewater Chloride concentration Spectrophotometric method Range PN-EN ISO 15923-1:2025-02","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(2,00 - 2000) mg/l"}],"search_zh":"水、污水 氯化物浓度 分光光度法 范围 PN-EN ISO 15923-1:2025-02","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a8369ecaf14b9c0e7b1dd83","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(2,00 - 2000) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie siarczanów\nZakres (2,00 - 2000) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 15923-1:2025-02","norm_bases":["PN-EN ISO 15923-1:2025-02"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie siarczanów\nZakres (2,00 - 2000) mg/l\nMetoda spektrofotometryczna PN-EN ISO 15923-1:2025-02 Woda, Scieki Stezenie siarczanow\nZakres (2,00 - 2000) mg/l\nMetoda spektrofotometryczna PN-EN ISO 15923-1:2025-02","categories":["water"],"row_index":353,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Range","range":"(2,00 - 2000) mg/l"}],"search_en":"Water, Wastewater Sulfate concentration Spectrophotometric method Range PN-EN ISO 15923-1:2025-02","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(2,00 - 2000) mg/l"}],"search_zh":"水、污水 硫酸盐浓度 分光光度法 范围 PN-EN ISO 15923-1:2025-02","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a8369ecaf14b9c0e7b1dd84","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,04 - 1000) mg/l"},{"name":"Stężenie jonu amonowego"},{"name":"Zakres","range":"(0,05 – 1200) mg/l"}],"technique":"Metoda spektrofotometryczna; Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna","Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres:\nZakres (0,04 - 1000) mg/l\nStężenie jonu amonowego\nZakres (0,05 – 1200) mg/l\nMetoda spektrofotometryczna; Metoda spektrofotometryczna","reference":"PN-EN ISO 15923-1:2025-02","norm_bases":["PN-EN ISO 15923-1:2025-02"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie azotu amonowego\nZakres:\nZakres (0,04 - 1000) mg/l\nStężenie jonu amonowego\nZakres (0,05 – 1200) mg/l\nMetoda spektrofotometryczna; Metoda spektrofotometryczna PN-EN ISO 15923-1:2025-02 Woda, Scieki Stezenie azotu amonowego\nZakres:\nZakres (0,04 - 1000) mg/l\nStezenie jonu amonowego\nZakres (0,05 – 1200) mg/l\nMetoda spektrofotometryczna; Metoda spektrofotometryczna PN-EN ISO 15923-1:2025-02","categories":["water"],"row_index":354,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,04 - 1000) mg/l"},{"name":"Ammonium ion concentration"},{"name":"Range","range":"(0,05 – 1200) mg/l"}],"search_en":"Water, Wastewater Ammonium nitrogen concentration Spectrophotometric method; Spectrophotometric method Range Ammonium ion concentration Range PN-EN ISO 15923-1:2025-02","technique_en":"Spectrophotometric method; Spectrophotometric method","test_object_en":"Water, Wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,04 - 1000) mg/l"},{"name":"铵离子浓度"},{"name":"范围","range":"(0,05 – 1200) mg/l"}],"search_zh":"水、污水 氨氮浓度 分光光度法；分光光度法 范围 铵离子浓度 范围 PN-EN ISO 15923-1:2025-02","test_object_zh":"水、污水","technique_zh":"分光光度法；分光光度法"},{"_id":"6a8369ecaf14b9c0e7b1dd85","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,01 - 50) mg/l"},{"name":"Stężenie azotynów"},{"name":"Zakres","range":"(0,03 – 150) mg/l"}],"technique":"Metoda spektrofotometryczna; Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna","Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres:\nZakres (0,01 - 50) mg/l\nStężenie azotynów\nZakres (0,03 – 150) mg/l\nMetoda spektrofotometryczna; Metoda spektrofotometryczna","reference":"PN-EN ISO 15923-1:2025-02","norm_bases":["PN-EN ISO 15923-1:2025-02"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie azotu azotynowego\nZakres:\nZakres (0,01 - 50) mg/l\nStężenie azotynów\nZakres (0,03 – 150) mg/l\nMetoda spektrofotometryczna; Metoda spektrofotometryczna PN-EN ISO 15923-1:2025-02 Woda, Scieki Stezenie azotu azotynowego\nZakres:\nZakres (0,01 - 50) mg/l\nStezenie azotynow\nZakres (0,03 – 150) mg/l\nMetoda spektrofotometryczna; Metoda spektrofotometryczna PN-EN ISO 15923-1:2025-02","categories":["water"],"row_index":355,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,01 - 50) mg/l"},{"name":"Nitrite concentration"},{"name":"Range","range":"(0,03 – 150) mg/l"}],"search_en":"Water, Wastewater Nitrite nitrogen concentration Spectrophotometric method; Spectrophotometric method Range Nitrite concentration Range PN-EN ISO 15923-1:2025-02","technique_en":"Spectrophotometric method; Spectrophotometric method","test_object_en":"Water, Wastewater","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,01 - 50) mg/l"},{"name":"亚硝酸盐浓度"},{"name":"范围","range":"(0,03 – 150) mg/l"}],"search_zh":"水、污水 亚硝态氮浓度 分光光度法；分光光度法 范围 亚硝酸盐浓度 范围 PN-EN ISO 15923-1:2025-02","test_object_zh":"水、污水","technique_zh":"分光光度法；分光光度法"},{"_id":"6a8369ecaf14b9c0e7b1dd86","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie fluorków","parameters":[{"name":"Zakres","range":"(0,10 - 100) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fluorków\nZakres (0,10 - 100) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 15923-1:2025-02","norm_bases":["PN-EN ISO 15923-1:2025-02"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie fluorków\nZakres (0,10 - 100) mg/l\nMetoda spektrofotometryczna PN-EN ISO 15923-1:2025-02 Woda, Scieki Stezenie fluorkow\nZakres (0,10 - 100) mg/l\nMetoda spektrofotometryczna PN-EN ISO 15923-1:2025-02","categories":["water"],"row_index":356,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fluoride concentration","parameters_en":[{"name":"Range","range":"(0,10 - 100) mg/l"}],"search_en":"Water, Wastewater Fluoride concentration Spectrophotometric method Range PN-EN ISO 15923-1:2025-02","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(0,10 - 100) mg/l"}],"search_zh":"水、污水 氟化物浓度 分光光度法 范围 PN-EN ISO 15923-1:2025-02","technique_zh":"分光光度法","test_object_zh":"水、污水","methodology_zh":"氟化物浓度"},{"_id":"6a8369ecaf14b9c0e7b1dd87","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie ortofosforanów","parameters":[{"name":"Zakres","range":"(0,40 - 400) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie ortofosforanów\nZakres (0,40 - 400) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 15923-1:2025-02","norm_bases":["PN-EN ISO 15923-1:2025-02"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie ortofosforanów\nZakres (0,40 - 400) mg/l\nMetoda spektrofotometryczna PN-EN ISO 15923-1:2025-02 Woda, Scieki Stezenie ortofosforanow\nZakres (0,40 - 400) mg/l\nMetoda spektrofotometryczna PN-EN ISO 15923-1:2025-02","categories":["water"],"row_index":357,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Orthophosphate concentration","parameters_en":[{"name":"Range","range":"(0,40 - 400) mg/l"}],"search_en":"Water, Wastewater Orthophosphate concentration Spectrophotometric method Range PN-EN ISO 15923-1:2025-02","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(0,40 - 400) mg/l"}],"search_zh":"水、污水 正磷酸盐浓度 分光光度法 范围 PN-EN ISO 15923-1:2025-02","technique_zh":"分光光度法","test_object_zh":"水、污水","methodology_zh":"正磷酸盐浓度"},{"_id":"6a8369ecaf14b9c0e7b1dd88","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie formaldehydu","parameters":[{"name":"Zakres","range":"(0,10 - 150) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie formaldehydu\nZakres (0,10 - 150) mg/l\nMetoda spektrofotometryczna","reference":"PB-DAN-08 wersja 02 z dnia 28.02.2025 r. na podstawie testu kuwetowego Merck nr 1.14678.0001","norm_bases":["PB-DAN-08 wersja 02 z dnia 28.02.2025 r. na podstawie testu kuwetowego Merck nr 1.14678.0001"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie formaldehydu\nZakres (0,10 - 150) mg/l\nMetoda spektrofotometryczna PB-DAN-08 wersja 02 z dnia 28.02.2025 r. na podstawie testu kuwetowego Merck nr 1.14678.0001 Woda, Scieki Stezenie formaldehydu\nZakres (0,10 - 150) mg/l\nMetoda spektrofotometryczna PB-DAN-08 wersja 02 z dnia 28.02.2025 r. na podstawie testu kuwetowego Merck nr 1.14678.0001","categories":["water"],"row_index":358,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Formaldehyde concentration","parameters_en":[{"name":"Range","range":"(0,10 - 150) mg/l"}],"search_en":"Water, Wastewater Formaldehyde concentration Spectrophotometric method Range PB-DAN-08 wersja 02 z dnia 28.02.2025 r. na podstawie testu kuwetowego Merck nr 1.14678.0001","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(0,10 - 150) mg/l"}],"search_zh":"水、污水 甲醛浓度 分光光度法 范围 PB-DAN-08 wersja 02 z dnia 28.02.2025 r. na podstawie testu kuwetowego Merck nr 1.14678.0001","technique_zh":"分光光度法","test_object_zh":"水、污水","methodology_zh":"甲醛浓度"},{"_id":"6a8369ecaf14b9c0e7b1dd89","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie siarczków","parameters":[{"name":"Zakres","range":"(0,10 - 50,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie siarczków\nZakres (0,10 - 50,0) mg/l\nMetoda spektrofotometryczna","reference":"PB-DAN-07 wersja 01 z dnia 30.03.2020 r. na podstawie testu kuwetowego Merck nr 1.14779.0001","norm_bases":["PB-DAN-07 wersja 01 z dnia 30.03.2020 r. na podstawie testu kuwetowego Merck nr 1.14779.0001"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie siarczków\nZakres (0,10 - 50,0) mg/l\nMetoda spektrofotometryczna PB-DAN-07 wersja 01 z dnia 30.03.2020 r. na podstawie testu kuwetowego Merck nr 1.14779.0001 Woda, Scieki Stezenie siarczkow\nZakres (0,10 - 50,0) mg/l\nMetoda spektrofotometryczna PB-DAN-07 wersja 01 z dnia 30.03.2020 r. na podstawie testu kuwetowego Merck nr 1.14779.0001","categories":["water"],"row_index":359,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfide concentration","parameters_en":[{"name":"Range","range":"(0,10 - 50,0) mg/l"}],"search_en":"Water, Wastewater Sulfide concentration Spectrophotometric method Range PB-DAN-07 wersja 01 z dnia 30.03.2020 r. na podstawie testu kuwetowego Merck nr 1.14779.0001","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(0,10 - 50,0) mg/l"}],"search_zh":"水、污水 硫化物浓度 分光光度法 范围 PB-DAN-07 wersja 01 z dnia 30.03.2020 r. na podstawie testu kuwetowego Merck nr 1.14779.0001","technique_zh":"分光光度法","test_object_zh":"水、污水","methodology_zh":"硫化物浓度"},{"_id":"6a8369ecaf14b9c0e7b1dd8a","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie siarkowodoru (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie siarkowodoru (z obliczeń)","reference":"PB-DAN-07 wersja 01 z dnia 30.03.2020 r. na podstawie testu kuwetowego Merck nr 1.14779.0001","norm_bases":["PB-DAN-07 wersja 01 z dnia 30.03.2020 r. na podstawie testu kuwetowego Merck nr 1.14779.0001"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie siarkowodoru (z obliczeń) PB-DAN-07 wersja 01 z dnia 30.03.2020 r. na podstawie testu kuwetowego Merck nr 1.14779.0001 Woda, Scieki Stezenie siarkowodoru (z obliczen) PB-DAN-07 wersja 01 z dnia 30.03.2020 r. na podstawie testu kuwetowego Merck nr 1.14779.0001","categories":["water"],"row_index":360,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrogen sulphide concentration (calculated)","search_en":"Water, Wastewater Hydrogen sulphide concentration (calculated) PB-DAN-07 wersja 01 z dnia 30.03.2020 r. na podstawie testu kuwetowego Merck nr 1.14779.0001","test_object_en":"Water, Wastewater","search_zh":"水、污水 PB-DAN-07 wersja 01 z dnia 30.03.2020 r. na podstawie testu kuwetowego Merck nr 1.14779.0001","test_object_zh":"水、污水"},{"_id":"6a8369ecaf14b9c0e7b1dd8b","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Ścieki oczyszczone","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(5 - 500) mg/l Pt"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Barwa\nZakres (5 - 500) mg/l Pt\nMetoda wizualna","reference":"PN-EN ISO 7887:2012 +Ap1:2015-06","norm_bases":["PN-EN ISO 7887:2012 +Ap1:2015-06"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki oczyszczone Barwa\nZakres (5 - 500) mg/l Pt\nMetoda wizualna PN-EN ISO 7887:2012 +Ap1:2015-06 Scieki oczyszczone Barwa\nZakres (5 - 500) mg/l Pt\nMetoda wizualna PN-EN ISO 7887:2012 +Ap1:2015-06","categories":["water"],"row_index":361,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"(5 - 500) mg/l Pt"}],"search_en":"Treated wastewater Colour Visual method Range PN-EN ISO 7887:2012 +Ap1:2015-06","technique_en":"Visual method","test_object_en":"Treated wastewater","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(5 - 500) mg/l Pt"}],"search_zh":"处理后废水 色度 目视法 范围 PN-EN ISO 7887:2012 +Ap1:2015-06","technique_zh":"目视法","test_object_zh":"处理后废水"},{"_id":"6a8369ecaf14b9c0e7b1dd8c","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,50 - 2000) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,50 - 2000) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 11732:2007","norm_bases":["PN-EN ISO 11732:2007"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu amonowego\nZakres (0,50 - 2000) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 11732:2007 Scieki Stezenie azotu amonowego\nZakres (0,50 - 2000) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 11732:2007","categories":["water"],"row_index":362,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,50 - 2000) mg/l"}],"search_en":"Wastewater Ammonium nitrogen concentration Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN ISO 11732:2007","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,50 - 2000) mg/l"}],"search_zh":"污水 氨氮浓度 连续流动分析（CFA）分光光度检测法 范围 PN-EN ISO 11732:2007","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"污水"},{"_id":"6a8369ecaf14b9c0e7b1dd8d","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie jonu amonowego","parameters":[{"name":"Zakres","range":"(0,60 – 2400) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie jonu amonowego\nZakres (0,60 – 2400) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 11732:2007","norm_bases":["PN-EN ISO 11732:2007"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie jonu amonowego\nZakres (0,60 – 2400) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 11732:2007 Scieki Stezenie jonu amonowego\nZakres (0,60 – 2400) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 11732:2007","categories":["water"],"row_index":363,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium ion concentration","parameters_en":[{"name":"Range","range":"(0,60 – 2400) mg/l"}],"search_en":"Wastewater Ammonium ion concentration Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN ISO 11732:2007","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Wastewater","methodology_zh":"铵离子浓度","parameters_zh":[{"name":"范围","range":"(0,60 – 2400) mg/l"}],"search_zh":"污水 铵离子浓度 连续流动分析（CFA）分光光度检测法 范围 PN-EN ISO 11732:2007","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"污水"},{"_id":"6a8369ecaf14b9c0e7b1dd8e","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,10 - 50) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres (0,10 - 50) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 13395:2001","norm_bases":["PN-EN ISO 13395:2001"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu azotynowego\nZakres (0,10 - 50) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 13395:2001 Scieki Stezenie azotu azotynowego\nZakres (0,10 - 50) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 13395:2001","categories":["water"],"row_index":364,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,10 - 50) mg/l"}],"search_en":"Wastewater Nitrite nitrogen concentration Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN ISO 13395:2001","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Wastewater","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,10 - 50) mg/l"}],"search_zh":"污水 亚硝态氮浓度 连续流动分析（CFA）分光光度检测法 范围 PN-EN ISO 13395:2001","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"污水"},{"_id":"6a8369ecaf14b9c0e7b1dd8f","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotynów","parameters":[{"name":"Zakres","range":"(0,30 - 150) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie azotynów\nZakres (0,30 - 150) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 13395:2001","norm_bases":["PN-EN ISO 13395:2001"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotynów\nZakres (0,30 - 150) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 13395:2001 Scieki Stezenie azotynow\nZakres (0,30 - 150) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 13395:2001","categories":["water"],"row_index":365,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite concentration","parameters_en":[{"name":"Range","range":"(0,30 - 150) mg/l"}],"search_en":"Wastewater Nitrite concentration Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN ISO 13395:2001","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Wastewater","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,30 - 150) mg/l"}],"search_zh":"污水 亚硝酸盐浓度 连续流动分析（CFA）分光光度检测法 范围 PN-EN ISO 13395:2001","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"污水"},{"_id":"6a8369ecaf14b9c0e7b1dd90","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu azotanowego","parameters":[{"name":"Zakres","range":"(1,00 - 1000) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie azotu azotanowego\nZakres (1,00 - 1000) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 13395:2001","norm_bases":["PN-EN ISO 13395:2001"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu azotanowego\nZakres (1,00 - 1000) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 13395:2001 Scieki Stezenie azotu azotanowego\nZakres (1,00 - 1000) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 13395:2001","categories":["water"],"row_index":366,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate nitrogen concentration","parameters_en":[{"name":"Range","range":"(1,00 - 1000) mg/l"}],"search_en":"Wastewater Nitrate nitrogen concentration Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN ISO 13395:2001","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Wastewater","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(1,00 - 1000) mg/l"}],"search_zh":"污水 硝态氮浓度 连续流动分析（CFA）分光光度检测法 范围 PN-EN ISO 13395:2001","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"污水"},{"_id":"6a8369ecaf14b9c0e7b1dd91","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotanów","parameters":[{"name":"Zakres","range":"(4,50 - 4000) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie azotanów\nZakres (4,50 - 4000) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 13395:2001","norm_bases":["PN-EN ISO 13395:2001"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotanów\nZakres (4,50 - 4000) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 13395:2001 Scieki Stezenie azotanow\nZakres (4,50 - 4000) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 13395:2001","categories":["water"],"row_index":367,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate concentration","parameters_en":[{"name":"Range","range":"(4,50 - 4000) mg/l"}],"search_en":"Wastewater Nitrate concentration Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN ISO 13395:2001","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Wastewater","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(4,50 - 4000) mg/l"}],"search_zh":"污水 硝酸盐浓度 连续流动分析（CFA）分光光度检测法 范围 PN-EN ISO 13395:2001","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"污水"},{"_id":"6a8369ecaf14b9c0e7b1dd92","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie chloru całkowitego","parameters":[{"name":"Zakres","range":"(0,0004 - 0,07) mmol/l"},{"name":"Zakres","range":"(0,03 - 5,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chloru całkowitego\nZakres:\nZakres (0,0004 - 0,07) mmol/l\nZakres (0,03 - 5,00) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7393-2:2018-04","norm_bases":["PN-EN ISO 7393-2:2018-04"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie chloru całkowitego\nZakres:\nZakres (0,0004 - 0,07) mmol/l\nZakres (0,03 - 5,00) mg/l\nMetoda spektrofotometryczna PN-EN ISO 7393-2:2018-04 Scieki Stezenie chloru calkowitego\nZakres:\nZakres (0,0004 - 0,07) mmol/l\nZakres (0,03 - 5,00) mg/l\nMetoda spektrofotometryczna PN-EN ISO 7393-2:2018-04","categories":["water"],"row_index":368,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total chlorine concentration","parameters_en":[{"name":"Range","range":"(0,0004 - 0,07) mmol/l"},{"name":"Range","range":"(0,03 - 5,00) mg/l"}],"search_en":"Wastewater Total chlorine concentration Spectrophotometric method Range Range PN-EN ISO 7393-2:2018-04","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(0,0004 - 0,07) mmol/l"},{"name":"范围","range":"(0,03 - 5,00) mg/l"}],"search_zh":"污水 总氯浓度 分光光度法 范围 范围 PN-EN ISO 7393-2:2018-04","technique_zh":"分光光度法","test_object_zh":"污水","methodology_zh":"总氯浓度"},{"_id":"6a8369ecaf14b9c0e7b1dd93","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie chloru całkowitego","parameters":[{"name":"Zakres","range":"(0,05 - 6,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chloru całkowitego\nZakres (0,05 - 6,00) mg/l\nMetoda spektrofotometryczna","reference":"PB-DAN-06 wersja 01 z dnia 20.04.2020 r. na podstawie testu kuwetowego Merck nr 1.00599.0001","norm_bases":["PB-DAN-06 wersja 01 z dnia 20.04.2020 r. na podstawie testu kuwetowego Merck nr 1.00599.0001"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie chloru całkowitego\nZakres (0,05 - 6,00) mg/l\nMetoda spektrofotometryczna PB-DAN-06 wersja 01 z dnia 20.04.2020 r. na podstawie testu kuwetowego Merck nr 1.00599.0001 Scieki Stezenie chloru calkowitego\nZakres (0,05 - 6,00) mg/l\nMetoda spektrofotometryczna PB-DAN-06 wersja 01 z dnia 20.04.2020 r. na podstawie testu kuwetowego Merck nr 1.00599.0001","categories":["water"],"row_index":369,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total chlorine concentration","parameters_en":[{"name":"Range","range":"(0,05 - 6,00) mg/l"}],"search_en":"Wastewater Total chlorine concentration Spectrophotometric method Range PB-DAN-06 wersja 01 z dnia 20.04.2020 r. na podstawie testu kuwetowego Merck nr 1.00599.0001","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(0,05 - 6,00) mg/l"}],"search_zh":"污水 总氯浓度 分光光度法 范围 PB-DAN-06 wersja 01 z dnia 20.04.2020 r. na podstawie testu kuwetowego Merck nr 1.00599.0001","technique_zh":"分光光度法","test_object_zh":"污水","methodology_zh":"总氯浓度"},{"_id":"6a8369ecaf14b9c0e7b1dd94","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie rtęci","parameters":[{"name":"Zakres","range":"(0,0005 - 0,2) mg/l"}],"technique":"Metoda atomowej spektrometrii fluorescencyjnej (AFS)","techniques":["Metoda atomowej spektrometrii fluorescencyjnej (AFS)"],"computed":[],"activity":"Stężenie rtęci\nZakres (0,0005 - 0,2) mg/l\nMetoda atomowej spektrometrii fluorescencyjnej (AFS)","reference":"PN-EN ISO 17852:2009","norm_bases":["PN-EN ISO 17852:2009"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie rtęci\nZakres (0,0005 - 0,2) mg/l\nMetoda atomowej spektrometrii fluorescencyjnej (AFS) PN-EN ISO 17852:2009 Scieki Stezenie rteci\nZakres (0,0005 - 0,2) mg/l\nMetoda atomowej spektrometrii fluorescencyjnej (AFS) PN-EN ISO 17852:2009","categories":["water"],"row_index":370,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury concentration","parameters_en":[{"name":"Range","range":"(0,0005 - 0,2) mg/l"}],"search_en":"Wastewater Mercury concentration Atomic fluorescence spectrometry (AFS) Range PN-EN ISO 17852:2009","technique_en":"Atomic fluorescence spectrometry (AFS)","test_object_en":"Wastewater","methodology_zh":"汞浓度","parameters_zh":[{"name":"范围","range":"(0,0005 - 0,2) mg/l"}],"search_zh":"污水 汞浓度 原子荧光光谱法（AFS） 范围 PN-EN ISO 17852:2009","test_object_zh":"污水","technique_zh":"原子荧光光谱法（AFS）"},{"_id":"6a8369ecaf14b9c0e7b1dd95","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Ścieki, Odcieki","methodology":"Stężenie rtęci","parameters":[{"name":"Zakres","range":"(0,0005 - 0,30) mg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","techniques":["Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji"],"computed":[],"activity":"Stężenie rtęci\nZakres (0,0005 - 0,30) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","reference":"PB-DAN-24 wersja 01 z dnia 16.02.2021 r.","norm_bases":["PB-DAN-24 wersja 01 z dnia 16.02.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, Odcieki Stężenie rtęci\nZakres (0,0005 - 0,30) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji PB-DAN-24 wersja 01 z dnia 16.02.2021 r. Scieki, Odcieki Stezenie rteci\nZakres (0,0005 - 0,30) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z technika amalgamacji PB-DAN-24 wersja 01 z dnia 16.02.2021 r.","categories":["water"],"row_index":371,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury concentration","parameters_en":[{"name":"Range","range":"(0,0005 - 0,30) mg/l"}],"search_en":"Wastewater, Leachates Mercury concentration Atomic absorption spectrometry with amalgamation technique Range PB-DAN-24 wersja 01 z dnia 16.02.2021 r.","technique_en":"Atomic absorption spectrometry with amalgamation technique","test_object_en":"Wastewater, Leachates","methodology_zh":"汞浓度","parameters_zh":[{"name":"范围","range":"(0,0005 - 0,30) mg/l"}],"search_zh":"汞浓度 原子吸收光谱法（汞齐化技术） 范围 PB-DAN-24 wersja 01 z dnia 16.02.2021 r.","technique_zh":"原子吸收光谱法（汞齐化技术）"},{"_id":"6a8369ecaf14b9c0e7b1dd96","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda (w tym, woda na pływalniach)","methodology":"Stężenie azotu azotanowego","parameters":[{"name":"Zakres","range":"(1,00 - 1000) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie azotu azotanowego\nZakres (1,00 - 1000) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 13395:2001","norm_bases":["PN-EN ISO 13395:2001"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym, woda na pływalniach) Stężenie azotu azotanowego\nZakres (1,00 - 1000) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 13395:2001 Woda (w tym, woda na plywalniach) Stezenie azotu azotanowego\nZakres (1,00 - 1000) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 13395:2001","categories":["water"],"row_index":372,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate nitrogen concentration","parameters_en":[{"name":"Range","range":"(1,00 - 1000) mg/l"}],"search_en":"Water (including, swimming pool water) Nitrate nitrogen concentration Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN ISO 13395:2001","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Water (including, swimming pool water)","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(1,00 - 1000) mg/l"}],"search_zh":"水（含游泳池水） 硝态氮浓度 连续流动分析（CFA）分光光度检测法 范围 PN-EN ISO 13395:2001","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"水（含游泳池水）"},{"_id":"6a8369ecaf14b9c0e7b1dd97","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda (w tym, woda na pływalniach)","methodology":"Stężenie azotanów","parameters":[{"name":"Zakres","range":"(4,50 - 4000) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie azotanów\nZakres (4,50 - 4000) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 13395:2001","norm_bases":["PN-EN ISO 13395:2001"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym, woda na pływalniach) Stężenie azotanów\nZakres (4,50 - 4000) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 13395:2001 Woda (w tym, woda na plywalniach) Stezenie azotanow\nZakres (4,50 - 4000) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 13395:2001","categories":["water"],"row_index":373,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate concentration","parameters_en":[{"name":"Range","range":"(4,50 - 4000) mg/l"}],"search_en":"Water (including, swimming pool water) Nitrate concentration Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN ISO 13395:2001","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Water (including, swimming pool water)","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(4,50 - 4000) mg/l"}],"search_zh":"水（含游泳池水） 硝酸盐浓度 连续流动分析（CFA）分光光度检测法 范围 PN-EN ISO 13395:2001","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"水（含游泳池水）"},{"_id":"6a8369ecaf14b9c0e7b1dd98","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Stężenie kwasu izocyjanurowego","parameters":[{"name":"Zakres","range":"(3 - 160) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie kwasu izocyjanurowego\nZakres (3 - 160) mg/l\nMetoda spektrofotometryczna","reference":"PB-DAN-09 wersja 01 z dnia 30.03.2020 r. na podstawie testu kuwetowego Merck nr 1.19253.0001","norm_bases":["PB-DAN-09 wersja 01 z dnia 30.03.2020 r. na podstawie testu kuwetowego Merck nr 1.19253.0001"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Stężenie kwasu izocyjanurowego\nZakres (3 - 160) mg/l\nMetoda spektrofotometryczna PB-DAN-09 wersja 01 z dnia 30.03.2020 r. na podstawie testu kuwetowego Merck nr 1.19253.0001 Woda na plywalniach Stezenie kwasu izocyjanurowego\nZakres (3 - 160) mg/l\nMetoda spektrofotometryczna PB-DAN-09 wersja 01 z dnia 30.03.2020 r. na podstawie testu kuwetowego Merck nr 1.19253.0001","categories":["water"],"row_index":374,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Isocyanuric acid concentration","parameters_en":[{"name":"Range","range":"(3 - 160) mg/l"}],"search_en":"Swimming pool water Isocyanuric acid concentration Spectrophotometric method Range PB-DAN-09 wersja 01 z dnia 30.03.2020 r. na podstawie testu kuwetowego Merck nr 1.19253.0001","technique_en":"Spectrophotometric method","test_object_en":"Swimming pool water","parameters_zh":[{"name":"范围","range":"(3 - 160) mg/l"}],"search_zh":"游泳池水 异氰尿酸浓度 分光光度法 范围 PB-DAN-09 wersja 01 z dnia 30.03.2020 r. na podstawie testu kuwetowego Merck nr 1.19253.0001","technique_zh":"分光光度法","test_object_zh":"游泳池水","methodology_zh":"异氰尿酸浓度"},{"_id":"6a8369ecaf14b9c0e7b1dd99","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda","methodology":"Liczba progowa smaku (TFN)","parameters":[{"name":"Zakres","range":"(1 - 4)"}],"technique":"Metoda uproszczona, parzysta, wybór niewymuszony","techniques":["Metoda uproszczona, parzysta, wybór niewymuszony"],"computed":[],"activity":"Liczba progowa smaku (TFN)\nZakres (1 - 4)\nMetoda uproszczona, parzysta, wybór niewymuszony","reference":"PN-EN 1622:2006","norm_bases":["PN-EN 1622:2006"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Liczba progowa smaku (TFN)\nZakres (1 - 4)\nMetoda uproszczona, parzysta, wybór niewymuszony PN-EN 1622:2006 Woda Liczba progowa smaku (TFN)\nZakres (1 - 4)\nMetoda uproszczona, parzysta, wybor niewymuszony PN-EN 1622:2006","categories":["water"],"row_index":375,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Taste threshold number (TFN)","parameters_en":[{"name":"Range","range":"(1 - 4)"}],"search_en":"Water Taste threshold number (TFN) Simplified method, paired, non-forced choice Range PN-EN 1622:2006","technique_en":"Simplified method, paired, non-forced choice","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(1 - 4)"}],"search_zh":"水 味阈值（TFN） 简化法，成对，非强制选择 范围 PN-EN 1622:2006","test_object_zh":"水","technique_zh":"简化法，成对，非强制选择","methodology_zh":"味阈值（TFN）"},{"_id":"6a8369ecaf14b9c0e7b1dd9a","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda","methodology":"Liczba progowa zapachu (TON)","parameters":[{"name":"Zakres","range":"(1 - 4)"}],"technique":"Metoda uproszczona, parzysta, wybór niewymuszony","techniques":["Metoda uproszczona, parzysta, wybór niewymuszony"],"computed":[],"activity":"Liczba progowa zapachu (TON)\nZakres (1 - 4)\nMetoda uproszczona, parzysta, wybór niewymuszony","reference":"PN-EN 1622:2006","norm_bases":["PN-EN 1622:2006"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Liczba progowa zapachu (TON)\nZakres (1 - 4)\nMetoda uproszczona, parzysta, wybór niewymuszony PN-EN 1622:2006 Woda Liczba progowa zapachu (TON)\nZakres (1 - 4)\nMetoda uproszczona, parzysta, wybor niewymuszony PN-EN 1622:2006","categories":["water"],"row_index":376,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Odour threshold number (TON)","parameters_en":[{"name":"Range","range":"(1 - 4)"}],"search_en":"Water Odour threshold number (TON) Simplified method, paired, non-forced choice Range PN-EN 1622:2006","technique_en":"Simplified method, paired, non-forced choice","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(1 - 4)"}],"search_zh":"水 嗅阈值（TON） 简化法，成对，非强制选择 范围 PN-EN 1622:2006","test_object_zh":"水","technique_zh":"简化法，成对，非强制选择","methodology_zh":"嗅阈值（TON）"},{"_id":"6a8369ecaf14b9c0e7b1dd9b","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(5 - 500) mg/l Pt"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Barwa\nZakres (5 - 500) mg/l Pt\nMetoda wizualna","reference":"PN-EN ISO 7887:2012 +Ap1:2015-06","norm_bases":["PN-EN ISO 7887:2012 +Ap1:2015-06"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Barwa\nZakres (5 - 500) mg/l Pt\nMetoda wizualna PN-EN ISO 7887:2012 +Ap1:2015-06 Woda Barwa\nZakres (5 - 500) mg/l Pt\nMetoda wizualna PN-EN ISO 7887:2012 +Ap1:2015-06","categories":["water"],"row_index":377,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"(5 - 500) mg/l Pt"}],"search_en":"Water Colour Visual method Range PN-EN ISO 7887:2012 +Ap1:2015-06","technique_en":"Visual method","test_object_en":"Water","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(5 - 500) mg/l Pt"}],"search_zh":"水 色度 目视法 范围 PN-EN ISO 7887:2012 +Ap1:2015-06","technique_zh":"目视法","test_object_zh":"水"},{"_id":"6a8369ecaf14b9c0e7b1dd9c","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,01 - 50) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres (0,01 - 50) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 13395:2001","norm_bases":["PN-EN ISO 13395:2001"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie azotu azotynowego\nZakres (0,01 - 50) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 13395:2001 Woda Stezenie azotu azotynowego\nZakres (0,01 - 50) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 13395:2001","categories":["water"],"row_index":378,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,01 - 50) mg/l"}],"search_en":"Water Nitrite nitrogen concentration Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN ISO 13395:2001","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Water","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,01 - 50) mg/l"}],"search_zh":"水 亚硝态氮浓度 连续流动分析（CFA）分光光度检测法 范围 PN-EN ISO 13395:2001","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"水"},{"_id":"6a8369ecaf14b9c0e7b1dd9d","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie azotynów","parameters":[{"name":"Zakres","range":"(0,03 - 150) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie azotynów\nZakres (0,03 - 150) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 13395:2001","norm_bases":["PN-EN ISO 13395:2001"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie azotynów\nZakres (0,03 - 150) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 13395:2001 Woda Stezenie azotynow\nZakres (0,03 - 150) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 13395:2001","categories":["water"],"row_index":379,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite concentration","parameters_en":[{"name":"Range","range":"(0,03 - 150) mg/l"}],"search_en":"Water Nitrite concentration Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN ISO 13395:2001","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Water","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,03 - 150) mg/l"}],"search_zh":"水 亚硝酸盐浓度 连续流动分析（CFA）分光光度检测法 范围 PN-EN ISO 13395:2001","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"水"},{"_id":"6a8369ecaf14b9c0e7b1dd9e","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,04 - 1000) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,04 - 1000) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 11732:2007","norm_bases":["PN-EN ISO 11732:2007"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie azotu amonowego\nZakres (0,04 - 1000) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 11732:2007 Woda Stezenie azotu amonowego\nZakres (0,04 - 1000) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 11732:2007","categories":["water"],"row_index":380,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,04 - 1000) mg/l"}],"search_en":"Water Ammonium nitrogen concentration Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN ISO 11732:2007","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Water","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,04 - 1000) mg/l"}],"search_zh":"水 氨氮浓度 连续流动分析（CFA）分光光度检测法 范围 PN-EN ISO 11732:2007","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"水"},{"_id":"6a8369ecaf14b9c0e7b1dd9f","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie jonu amonowego","parameters":[{"name":"Zakres","range":"(0,05 - 1200) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie jonu amonowego\nZakres (0,05 - 1200) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 11732:2007","norm_bases":["PN-EN ISO 11732:2007"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie jonu amonowego\nZakres (0,05 - 1200) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 11732:2007 Woda Stezenie jonu amonowego\nZakres (0,05 - 1200) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 11732:2007","categories":["water"],"row_index":381,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium ion concentration","parameters_en":[{"name":"Range","range":"(0,05 - 1200) mg/l"}],"search_en":"Water Ammonium ion concentration Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN ISO 11732:2007","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Water","methodology_zh":"铵离子浓度","parameters_zh":[{"name":"范围","range":"(0,05 - 1200) mg/l"}],"search_zh":"水 铵离子浓度 连续流动分析（CFA）分光光度检测法 范围 PN-EN ISO 11732:2007","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"水"},{"_id":"6a8369ecaf14b9c0e7b1dda0","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie chlorków, azotanów, siarczanów, fluorków, bromków","parameters":[{"name":"Cl","range":"(2,50 - 2500) mg/l"},{"name":"NO3","range":"(0,50 - 8000) mg/l"},{"name":"SO42","range":"(2,50 - 1000) mg/l"},{"name":"F","range":"(0,10 - 50) mg/l"},{"name":"Br","range":"(0,05 - 300) mg/l"},{"name":"Suma chlorków i siarczanów (z obliczeń)"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie chlorków, azotanów, siarczanów, fluorków, bromków\nZakres:\nCl (2,50 - 2500) mg/l\nNO3 (0,50 - 8000) mg/l\nSO42 (2,50 - 1000) mg/l\nF (0,10 - 50) mg/l\nBr (0,05 - 300) mg/l\nSuma chlorków i siarczanów (z obliczeń)\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC 2012","norm_bases":["PN-EN ISO 10304-1:2009+AC 2012"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie chlorków, azotanów, siarczanów, fluorków, bromków\nZakres:\nCl (2,50 - 2500) mg/l\nNO3 (0,50 - 8000) mg/l\nSO42 (2,50 - 1000) mg/l\nF (0,10 - 50) mg/l\nBr (0,05 - 300) mg/l\nSuma chlorków i siarczanów (z obliczeń)\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC 2012 Woda Stezenie chlorkow, azotanow, siarczanow, fluorkow, bromkow\nZakres:\nCl (2,50 - 2500) mg/l\nNO3 (0,50 - 8000) mg/l\nSO42 (2,50 - 1000) mg/l\nF (0,10 - 50) mg/l\nBr (0,05 - 300) mg/l\nSuma chlorkow i siarczanow (z obliczen)\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC 2012","categories":["water"],"row_index":382,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of chlorides, nitrates, sulphates, fluorides, bromides","parameters_en":[{"name":"Cl","range":"(2,50 - 2500) mg/l"},{"name":"NO3","range":"(0,50 - 8000) mg/l"},{"name":"SO42","range":"(2,50 - 1000) mg/l"},{"name":"F","range":"(0,10 - 50) mg/l"},{"name":"Br","range":"(0,05 - 300) mg/l"},{"name":"Sum of chlorides and sulphates (calculated)"}],"search_en":"Water Concentration of chlorides, nitrates, sulphates, fluorides, bromides Ion chromatography with conductometric detection (IC-CD) Cl NO3 SO42 F Br Sum of chlorides and sulphates (calculated) PN-EN ISO 10304-1:2009+AC 2012","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water","search_zh":"水 离子色谱-电导检测法（IC-CD） 氯化物与硫酸盐总量（由计算得出） PN-EN ISO 10304-1:2009+AC 2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水","parameters_zh":[{"name":"Cl","range":"(2,50 - 2500) mg/l"},{"name":"NO3","range":"(0,50 - 8000) mg/l"},{"name":"SO42","range":"(2,50 - 1000) mg/l"},{"name":"F","range":"(0,10 - 50) mg/l"},{"name":"Br","range":"(0,05 - 300) mg/l"},{"name":"氯化物与硫酸盐总量（由计算得出）"}]},{"_id":"6a8369ecaf14b9c0e7b1dda1","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie bromianów rozpuszczonych","parameters":[{"name":"Zakres","range":"(5,00 - 250) μg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie bromianów rozpuszczonych\nZakres (5,00 - 250) μg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 15061:2003","norm_bases":["PN-EN ISO 15061:2003"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie bromianów rozpuszczonych\nZakres (5,00 - 250) μg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 15061:2003 Woda Stezenie bromianow rozpuszczonych\nZakres (5,00 - 250) μg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 15061:2003","categories":["water"],"row_index":383,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissolved bromate concentration","parameters_en":[{"name":"Range","range":"(5,00 - 250) μg/l"}],"search_en":"Water Dissolved bromate concentration Ion chromatography with conductometric detection (IC-CD) Range PN-EN ISO 15061:2003","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(5,00 - 250) μg/l"}],"search_zh":"水 离子色谱-电导检测法（IC-CD） 范围 PN-EN ISO 15061:2003","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水"},{"_id":"6a8369ecaf14b9c0e7b1dda2","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie chloranów, chlorynów","parameters":[{"name":"Zakres","range":"(0,10 - 100) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie chloranów, chlorynów\nZakres (0,10 - 100) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-4:2022-08","norm_bases":["PN-EN ISO 10304-4:2022-08"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie chloranów, chlorynów\nZakres (0,10 - 100) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-4:2022-08 Woda Stezenie chloranow, chlorynow\nZakres (0,10 - 100) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-4:2022-08","categories":["water"],"row_index":384,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chlorate, chlorite concentration","parameters_en":[{"name":"Range","range":"(0,10 - 100) mg/l"}],"search_en":"Water Chlorate, chlorite concentration Ion chromatography with conductometric detection (IC-CD) Range PN-EN ISO 10304-4:2022-08","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,10 - 100) mg/l"}],"search_zh":"水 氯酸盐、亚氯酸盐浓度 离子色谱-电导检测法（IC-CD） 范围 PN-EN ISO 10304-4:2022-08","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水","methodology_zh":"氯酸盐、亚氯酸盐浓度"},{"_id":"6a8369ecaf14b9c0e7b1dda3","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie rtęci","parameters":[{"name":"Zakres","range":"(0,000050 - 0,010) mg/l"}],"technique":"Metoda atomowej spektrometrii fluorescencyjnej (AFS)","techniques":["Metoda atomowej spektrometrii fluorescencyjnej (AFS)"],"computed":[],"activity":"Stężenie rtęci\nZakres (0,000050 - 0,010) mg/l\nMetoda atomowej spektrometrii fluorescencyjnej (AFS)","reference":"PN-EN ISO 17852:2009","norm_bases":["PN-EN ISO 17852:2009"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie rtęci\nZakres (0,000050 - 0,010) mg/l\nMetoda atomowej spektrometrii fluorescencyjnej (AFS) PN-EN ISO 17852:2009 Woda Stezenie rteci\nZakres (0,000050 - 0,010) mg/l\nMetoda atomowej spektrometrii fluorescencyjnej (AFS) PN-EN ISO 17852:2009","categories":["water"],"row_index":385,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury concentration","parameters_en":[{"name":"Range","range":"(0,000050 - 0,010) mg/l"}],"search_en":"Water Mercury concentration Atomic fluorescence spectrometry (AFS) Range PN-EN ISO 17852:2009","technique_en":"Atomic fluorescence spectrometry (AFS)","test_object_en":"Water","methodology_zh":"汞浓度","parameters_zh":[{"name":"范围","range":"(0,000050 - 0,010) mg/l"}],"search_zh":"水 汞浓度 原子荧光光谱法（AFS） 范围 PN-EN ISO 17852:2009","test_object_zh":"水","technique_zh":"原子荧光光谱法（AFS）"},{"_id":"6a8369ecaf14b9c0e7b1dda4","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda","methodology":"Zasadowość","parameters":[{"name":"Zakres","range":"(0,40 - 100) mmol/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zasadowość\nZakres (0,40 - 100) mmol/l\nMetoda spektrofotometryczna","reference":"ISO/TS 15923-2:2017-10","norm_bases":["ISO/TS 15923-2:2017-10"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Zasadowość\nZakres (0,40 - 100) mmol/l\nMetoda spektrofotometryczna ISO/TS 15923-2:2017-10 Woda Zasadowosc\nZakres (0,40 - 100) mmol/l\nMetoda spektrofotometryczna ISO/TS 15923-2:2017-10","categories":["water"],"row_index":386,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Alkalinity","parameters_en":[{"name":"Range","range":"(0,40 - 100) mmol/l"}],"search_en":"Water Alkalinity Spectrophotometric method Range ISO/TS 15923-2:2017-10","technique_en":"Spectrophotometric method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,40 - 100) mmol/l"}],"search_zh":"水 碱度 分光光度法 范围 ISO/TS 15923-2:2017-10","technique_zh":"分光光度法","test_object_zh":"水","methodology_zh":"碱度"},{"_id":"6a8369ecaf14b9c0e7b1dda5","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie wodorowęglanów","parameters":[{"name":"Zakres","range":"(25 - 6000) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie wodorowęglanów\nZakres (25 - 6000) mg/l\nMetoda spektrofotometryczna","reference":"ISO/TS 15923-2:2017-10","norm_bases":["ISO/TS 15923-2:2017-10"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie wodorowęglanów\nZakres (25 - 6000) mg/l\nMetoda spektrofotometryczna ISO/TS 15923-2:2017-10 Woda Stezenie wodoroweglanow\nZakres (25 - 6000) mg/l\nMetoda spektrofotometryczna ISO/TS 15923-2:2017-10","categories":["water"],"row_index":387,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Bicarbonate concentration","parameters_en":[{"name":"Range","range":"(25 - 6000) mg/l"}],"search_en":"Water Bicarbonate concentration Spectrophotometric method Range ISO/TS 15923-2:2017-10","technique_en":"Spectrophotometric method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(25 - 6000) mg/l"}],"search_zh":"水 分光光度法 范围 ISO/TS 15923-2:2017-10","technique_zh":"分光光度法","test_object_zh":"水"},{"_id":"6a8369ecaf14b9c0e7b1dda6","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda","methodology":"Twardość ogólna","parameters":[{"name":"Zakres","range":"(20,0 - 2000) mg/l CaCO3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Twardość ogólna\nZakres (20,0 - 2000) mg/l CaCO3\nMetoda spektrofotometryczna","reference":"ISO/TS 15923-2:2017-10","norm_bases":["ISO/TS 15923-2:2017-10"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Twardość ogólna\nZakres (20,0 - 2000) mg/l CaCO3\nMetoda spektrofotometryczna ISO/TS 15923-2:2017-10 Woda Twardosc ogolna\nZakres (20,0 - 2000) mg/l CaCO3\nMetoda spektrofotometryczna ISO/TS 15923-2:2017-10","categories":["water"],"row_index":388,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total hardness","parameters_en":[{"name":"Range","range":"(20,0 - 2000) mg/l CaCO3"}],"search_en":"Water Total hardness Spectrophotometric method Range ISO/TS 15923-2:2017-10","technique_en":"Spectrophotometric method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(20,0 - 2000) mg/l CaCO3"}],"search_zh":"水 总硬度 分光光度法 范围 ISO/TS 15923-2:2017-10","technique_zh":"分光光度法","test_object_zh":"水","methodology_zh":"总硬度"},{"_id":"6a8369ecaf14b9c0e7b1dda7","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"pH - w H2O","parameters":[{"name":"Zakres","range":"2,0 - 13,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH - w H2O\nZakres 2,0 - 13,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe pH - w H2O\nZakres 2,0 - 13,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 Osady sciekowe pH - w H2O\nZakres 2,0 - 13,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["water"],"row_index":389,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH - in H2O","parameters_en":[{"name":"Range","range":"2,0 - 13,0"}],"search_en":"Sewage sludge pH - in H2O Potentiometric method Range PN-EN ISO 10390:2022-09","technique_en":"Potentiometric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"2,0 - 13,0"}],"search_zh":"污泥 pH - 于 H2O 中 电位法 范围 PN-EN ISO 10390:2022-09","technique_zh":"电位法","test_object_zh":"污泥","methodology_zh":"pH - 于 H2O 中"},{"_id":"6a8369ecaf14b9c0e7b1dda8","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Zawartość ogólnego węgla organicznego (TOC)","parameters":[{"name":"Zakres","range":"(1 - 500) g/kg"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość ogólnego węgla organicznego (TOC)\nZakres (1 - 500) g/kg\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN 15936:2022-07","norm_bases":["PN-EN 15936:2022-07"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Zawartość ogólnego węgla organicznego (TOC)\nZakres (1 - 500) g/kg\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN 15936:2022-07 Osady sciekowe Zawartosc ogolnego wegla organicznego (TOC)\nZakres (1 - 500) g/kg\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN 15936:2022-07","categories":["water"],"row_index":390,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total organic carbon (TOC) content","parameters_en":[{"name":"Range","range":"(1 - 500) g/kg"}],"search_en":"Sewage sludge Total organic carbon (TOC) content High-temperature combustion with IR detection Range PN-EN 15936:2022-07","technique_en":"High-temperature combustion with IR detection","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(1 - 500) g/kg"}],"search_zh":"污泥 总有机碳（TOC）含量 高温燃烧红外检测法 范围 PN-EN 15936:2022-07","technique_zh":"高温燃烧红外检测法","test_object_zh":"污泥","methodology_zh":"总有机碳（TOC）含量"},{"_id":"6a8369ecaf14b9c0e7b1dda9","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Sucha masa / zawartość wody","parameters":[{"name":"Zakres","range":"(0,1 - 99,5) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha masa / zawartość wody\nZakres (0,1 - 99,5) %\nMetoda wagowa","reference":"PN-EN 15934:2013-02 z wył. p. 7, metoda B","norm_bases":["PN-EN 15934:2013-02 z wył. p. 7, metoda B"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Sucha masa / zawartość wody\nZakres (0,1 - 99,5) %\nMetoda wagowa PN-EN 15934:2013-02 z wył. p. 7, metoda B Osady sciekowe Sucha masa / zawartosc wody\nZakres (0,1 - 99,5) %\nMetoda wagowa PN-EN 15934:2013-02 z wyl. p. 7, metoda B","categories":["water"],"row_index":391,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry matter / water content","parameters_en":[{"name":"Range","range":"(0,1 - 99,5) %"}],"search_en":"Sewage sludge Dry matter / water content Gravimetric method Range PN-EN 15934:2013-02 z wył. p. 7, metoda B","technique_en":"Gravimetric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(0,1 - 99,5) %"}],"search_zh":"污泥 干物质 / 水分含量 重量法 范围 PN-EN 15934:2013-02 z wył. p. 7, metoda B","technique_zh":"重量法","test_object_zh":"污泥","methodology_zh":"干物质 / 水分含量"},{"_id":"6a8369ecaf14b9c0e7b1ddaa","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Osady czynne","methodology":"Zawiesina łatwoopadająca","parameters":[{"name":"Zakres","range":"(0,1 - 1000) ml/l"}],"technique":"Metoda objętościowa","techniques":["Metoda objętościowa"],"computed":[],"activity":"Zawiesina łatwoopadająca\nZakres (0,1 - 1000) ml/l\nMetoda objętościowa","reference":"PB-DAN-16 wersja 01 z dnia 16.02.2021 r.","norm_bases":["PB-DAN-16 wersja 01 z dnia 16.02.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady czynne Zawiesina łatwoopadająca\nZakres (0,1 - 1000) ml/l\nMetoda objętościowa PB-DAN-16 wersja 01 z dnia 16.02.2021 r. Osady czynne Zawiesina latwoopadajaca\nZakres (0,1 - 1000) ml/l\nMetoda objetosciowa PB-DAN-16 wersja 01 z dnia 16.02.2021 r.","categories":["water"],"row_index":392,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Settleable solids","parameters_en":[{"name":"Range","range":"(0,1 - 1000) ml/l"}],"search_en":"Activated sludge Settleable solids Volumetric method Range PB-DAN-16 wersja 01 z dnia 16.02.2021 r.","technique_en":"Volumetric method","test_object_en":"Activated sludge","parameters_zh":[{"name":"范围","range":"(0,1 - 1000) ml/l"}],"search_zh":"活性污泥 容量法 范围 PB-DAN-16 wersja 01 z dnia 16.02.2021 r.","technique_zh":"容量法","test_object_zh":"活性污泥"},{"_id":"6a8369ecaf14b9c0e7b1ddab","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Osady czynne","methodology":"Indeks objętości osadu","parameters":[{"name":"Zakres","range":"(10 - 500) ml/g"}],"technique":"Metoda objętościowo-wagowa","techniques":["Metoda objętościowo-wagowa"],"computed":[],"activity":"Indeks objętości osadu\nZakres (10 - 500) ml/g\nMetoda objętościowo-wagowa","reference":"PN-EN 14702-1:2008","norm_bases":["PN-EN 14702-1:2008"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady czynne Indeks objętości osadu\nZakres (10 - 500) ml/g\nMetoda objętościowo-wagowa PN-EN 14702-1:2008 Osady czynne Indeks objetosci osadu\nZakres (10 - 500) ml/g\nMetoda objetosciowo-wagowa PN-EN 14702-1:2008","categories":["water"],"row_index":393,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sludge volume index","parameters_en":[{"name":"Range","range":"(10 - 500) ml/g"}],"search_en":"Activated sludge Sludge volume index Volumetric-gravimetric method Range PN-EN 14702-1:2008","technique_en":"Volumetric-gravimetric method","test_object_en":"Activated sludge","parameters_zh":[{"name":"范围","range":"(10 - 500) ml/g"}],"search_zh":"活性污泥 容量-重量法 范围 PN-EN 14702-1:2008","technique_zh":"容量-重量法","test_object_zh":"活性污泥"},{"_id":"6a8369ecaf14b9c0e7b1ddac","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Stałe paliwa wtórne","methodology":"Zawartość wody (wilgoci)","parameters":[{"name":"Zakres","range":"(1,0 - 99,5) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wody (wilgoci)\nZakres (1,0 - 99,5) %\nMetoda wagowa","reference":"PN-EN 15934:2013-02 z wył. p. 7, metoda B","norm_bases":["PN-EN 15934:2013-02 z wył. p. 7, metoda B"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Stałe paliwa wtórne Zawartość wody (wilgoci)\nZakres (1,0 - 99,5) %\nMetoda wagowa PN-EN 15934:2013-02 z wył. p. 7, metoda B Stale paliwa wtorne Zawartosc wody (wilgoci)\nZakres (1,0 - 99,5) %\nMetoda wagowa PN-EN 15934:2013-02 z wyl. p. 7, metoda B","categories":["water","petro"],"row_index":394,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water (moisture) content","parameters_en":[{"name":"Range","range":"(1,0 - 99,5) %"}],"search_en":"Solid recovered fuels Water (moisture) content Gravimetric method Range PN-EN 15934:2013-02 z wył. p. 7, metoda B","technique_en":"Gravimetric method","test_object_en":"Solid recovered fuels","parameters_zh":[{"name":"范围","range":"(1,0 - 99,5) %"}],"search_zh":"重量法 范围 PN-EN 15934:2013-02 z wył. p. 7, metoda B","technique_zh":"重量法"},{"_id":"6a8369ecaf14b9c0e7b1ddad","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Gleba, Paliwa stałe: biomasa stała – biopaliwo stałe","methodology":"Aktywność oddechowa AT4","parameters":[{"name":"Zakres","range":"(1,00 - 30,0) mg/g O2"}],"technique":"Metoda manometryczna","techniques":["Metoda manometryczna"],"computed":[],"activity":"Aktywność oddechowa AT4\nZakres (1,00 - 30,0) mg/g O2\nMetoda manometryczna","reference":"PB-DAN-19 wersja 01 z dnia 16.02.2021 r.","norm_bases":["PB-DAN-19 wersja 01 z dnia 16.02.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, Paliwa stałe: biomasa stała – biopaliwo stałe Aktywność oddechowa AT4\nZakres (1,00 - 30,0) mg/g O2\nMetoda manometryczna PB-DAN-19 wersja 01 z dnia 16.02.2021 r. Gleba, Paliwa stale: biomasa stala – biopaliwo stale Aktywnosc oddechowa AT4\nZakres (1,00 - 30,0) mg/g O2\nMetoda manometryczna PB-DAN-19 wersja 01 z dnia 16.02.2021 r.","categories":["petro","environment","metrology"],"row_index":395,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Respiration activity AT4","parameters_en":[{"name":"Range","range":"(1,00 - 30,0) mg/g O2"}],"search_en":"Soil, Solid fuels: solid biomass – solid biofuel Respiration activity AT4 Manometric method Range PB-DAN-19 wersja 01 z dnia 16.02.2021 r.","technique_en":"Manometric method","test_object_en":"Soil, Solid fuels: solid biomass – solid biofuel","parameters_zh":[{"name":"范围","range":"(1,00 - 30,0) mg/g O2"}],"search_zh":"呼吸活性 AT4 压力计法 范围 PB-DAN-19 wersja 01 z dnia 16.02.2021 r.","technique_zh":"压力计法","methodology_zh":"呼吸活性 AT4"},{"_id":"6a8369ecaf14b9c0e7b1ddae","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Gleba","methodology":"pH – w H2O, pH – w KCl","parameters":[{"name":"Zakres","range":"2,0 - 13,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH – w H2O, pH – w KCl\nZakres 2,0 - 13,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba pH – w H2O, pH – w KCl\nZakres 2,0 - 13,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 Gleba pH – w H2O, pH – w KCl\nZakres 2,0 - 13,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["environment"],"row_index":396,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH – in H2O, pH – in KCl","parameters_en":[{"name":"Range","range":"2,0 - 13,0"}],"search_en":"Soil pH – in H2O, pH – in KCl Potentiometric method Range PN-EN ISO 10390:2022-09","technique_en":"Potentiometric method","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"2,0 - 13,0"}],"search_zh":"土壤 pH － 于 H2O 中，pH － 于 KCl 中 电位法 范围 PN-EN ISO 10390:2022-09","technique_zh":"电位法","test_object_zh":"土壤","methodology_zh":"pH － 于 H2O 中，pH － 于 KCl 中"},{"_id":"6a8369ecaf14b9c0e7b1ddaf","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość fosforu przyswajalnego w przeliczeniu na P2O5","parameters":[{"name":"Zakres","range":"(1,00 - 150) mg/100g"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość fosforu przyswajalnego w przeliczeniu na P2O5\nZakres (1,00 - 150) mg/100g\nMetoda spektrofotometryczna","reference":"PN-R-04023:1996","norm_bases":["PN-R-04023:1996"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość fosforu przyswajalnego w przeliczeniu na P2O5\nZakres (1,00 - 150) mg/100g\nMetoda spektrofotometryczna PN-R-04023:1996 Gleba Zawartosc fosforu przyswajalnego w przeliczeniu na P2O5\nZakres (1,00 - 150) mg/100g\nMetoda spektrofotometryczna PN-R-04023:1996","categories":["environment"],"row_index":397,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Available phosphorus content calculated as P2O5","parameters_en":[{"name":"Range","range":"(1,00 - 150) mg/100g"}],"search_en":"Soil Available phosphorus content calculated as P2O5 Spectrophotometric method Range PN-R-04023:1996","technique_en":"Spectrophotometric method","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"(1,00 - 150) mg/100g"}],"search_zh":"土壤 分光光度法 范围 PN-R-04023:1996","technique_zh":"分光光度法","test_object_zh":"土壤"},{"_id":"6a8369ecaf14b9c0e7b1ddb0","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,10 - 50,0) mg/kg"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Zawartość azotu azotynowego\nZakres (0,10 - 50,0) mg/kg\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-ISO 14256-2:2010","norm_bases":["PN-ISO 14256-2:2010"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość azotu azotynowego\nZakres (0,10 - 50,0) mg/kg\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-ISO 14256-2:2010 Gleba Zawartosc azotu azotynowego\nZakres (0,10 - 50,0) mg/kg\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-ISO 14256-2:2010","categories":["environment"],"row_index":398,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite nitrogen content","parameters_en":[{"name":"Range","range":"(0,10 - 50,0) mg/kg"}],"search_en":"Soil Nitrite nitrogen content Continuous flow analysis (CFA) with spectrophotometric detection Range PN-ISO 14256-2:2010","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"(0,10 - 50,0) mg/kg"}],"search_zh":"土壤 亚硝酸盐氮含量 连续流动分析（CFA）分光光度检测法 范围 PN-ISO 14256-2:2010","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"土壤","methodology_zh":"亚硝酸盐氮含量"},{"_id":"6a8369ecaf14b9c0e7b1ddb1","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość azotu amonowego","parameters":[{"name":"Zakres","range":"(15,0 - 500) mg/kg"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Zawartość azotu amonowego\nZakres (15,0 - 500) mg/kg\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-ISO 14256-2:2010","norm_bases":["PN-ISO 14256-2:2010"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość azotu amonowego\nZakres (15,0 - 500) mg/kg\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-ISO 14256-2:2010 Gleba Zawartosc azotu amonowego\nZakres (15,0 - 500) mg/kg\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-ISO 14256-2:2010","categories":["environment"],"row_index":399,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen content","parameters_en":[{"name":"Range","range":"(15,0 - 500) mg/kg"}],"search_en":"Soil Ammonium nitrogen content Continuous flow analysis (CFA) with spectrophotometric detection Range PN-ISO 14256-2:2010","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"(15,0 - 500) mg/kg"}],"search_zh":"土壤 氨氮含量 连续流动分析（CFA）分光光度检测法 范围 PN-ISO 14256-2:2010","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"土壤","methodology_zh":"氨氮含量"},{"_id":"6a8369ecaf14b9c0e7b1ddb2","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość azotu azotanowego","parameters":[{"name":"Zakres","range":"(5,0 - 500) mg/kg"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Zawartość azotu azotanowego\nZakres (5,0 - 500) mg/kg\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-ISO 14256-2:2010","norm_bases":["PN-ISO 14256-2:2010"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość azotu azotanowego\nZakres (5,0 - 500) mg/kg\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-ISO 14256-2:2010 Gleba Zawartosc azotu azotanowego\nZakres (5,0 - 500) mg/kg\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-ISO 14256-2:2010","categories":["environment"],"row_index":400,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate nitrogen content","parameters_en":[{"name":"Range","range":"(5,0 - 500) mg/kg"}],"search_en":"Soil Nitrate nitrogen content Continuous flow analysis (CFA) with spectrophotometric detection Range PN-ISO 14256-2:2010","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"(5,0 - 500) mg/kg"}],"search_zh":"土壤 硝酸盐氮含量 连续流动分析（CFA）分光光度检测法 范围 PN-ISO 14256-2:2010","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"土壤","methodology_zh":"硝酸盐氮含量"},{"_id":"6a8369ecaf14b9c0e7b1ddb3","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość azotu mineralnego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość azotu mineralnego (z obliczeń)","reference":"PB-DAN-21 wersja 01 z dnia 16.02.2021 r.","norm_bases":["PB-DAN-21 wersja 01 z dnia 16.02.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość azotu mineralnego (z obliczeń) PB-DAN-21 wersja 01 z dnia 16.02.2021 r. Gleba Zawartosc azotu mineralnego (z obliczen) PB-DAN-21 wersja 01 z dnia 16.02.2021 r.","categories":["environment"],"row_index":401,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mineral nitrogen content (calculated)","search_en":"Soil Mineral nitrogen content (calculated) PB-DAN-21 wersja 01 z dnia 16.02.2021 r.","test_object_en":"Soil","search_zh":"土壤 矿质氮含量（由计算得出） PB-DAN-21 wersja 01 z dnia 16.02.2021 r.","test_object_zh":"土壤","methodology_zh":"矿质氮含量（由计算得出）"},{"_id":"6a8369ecaf14b9c0e7b1ddb4","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość cyjanków wolnych i związanych","parameters":[{"name":"Zakres","range":"(0,50 - 100) mg/kg"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Zawartość cyjanków wolnych i związanych\nZakres (0,50 - 100) mg/kg\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 17380:2013","norm_bases":["PN-EN ISO 17380:2013"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość cyjanków wolnych i związanych\nZakres (0,50 - 100) mg/kg\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 17380:2013 Gleba Zawartosc cyjankow wolnych i zwiazanych\nZakres (0,50 - 100) mg/kg\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 17380:2013","categories":["environment"],"row_index":402,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free and bound cyanide content","parameters_en":[{"name":"Range","range":"(0,50 - 100) mg/kg"}],"search_en":"Soil Free and bound cyanide content Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN ISO 17380:2013","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"(0,50 - 100) mg/kg"}],"search_zh":"土壤 连续流动分析（CFA）分光光度检测法 范围 PN-EN ISO 17380:2013","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"土壤"},{"_id":"6a8369ecaf14b9c0e7b1ddb5","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Gleba","methodology":"Sucha masa / zawartość wody","parameters":[{"name":"Zakres","range":"(0,5 - 99,5) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha masa / zawartość wody\nZakres (0,5 - 99,5) %\nMetoda wagowa","reference":"PN ISO 11465:1999","norm_bases":["PN ISO 11465:1999"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Sucha masa / zawartość wody\nZakres (0,5 - 99,5) %\nMetoda wagowa PN ISO 11465:1999 Gleba Sucha masa / zawartosc wody\nZakres (0,5 - 99,5) %\nMetoda wagowa PN ISO 11465:1999","categories":["water","environment"],"row_index":403,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry matter / water content","parameters_en":[{"name":"Range","range":"(0,5 - 99,5) %"}],"search_en":"Soil Dry matter / water content Gravimetric method Range PN ISO 11465:1999","technique_en":"Gravimetric method","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"(0,5 - 99,5) %"}],"search_zh":"土壤 干物质 / 水分含量 重量法 范围 PN ISO 11465:1999","technique_zh":"重量法","test_object_zh":"土壤","methodology_zh":"干物质 / 水分含量"},{"_id":"6a8369ecaf14b9c0e7b1ddb6","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość ogólnego węgla organicznego (OWO)","parameters":[{"name":"Zakres","range":"(5,0 - 500) g/kg"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość ogólnego węgla organicznego (OWO)\nZakres (5,0 - 500) g/kg\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN 10694:2002 | PN-EN 15936:2022-07","norm_bases":["PN-EN 10694:2002","PN-EN 15936:2022-07"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość ogólnego węgla organicznego (OWO)\nZakres (5,0 - 500) g/kg\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN 10694:2002 | PN-EN 15936:2022-07 Gleba Zawartosc ogolnego wegla organicznego (OWO)\nZakres (5,0 - 500) g/kg\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN 10694:2002 | PN-EN 15936:2022-07","categories":["environment"],"row_index":404,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total organic carbon (TOC) content","parameters_en":[{"name":"Range","range":"(5,0 - 500) g/kg"}],"search_en":"Soil Total organic carbon (TOC) content High-temperature combustion with IR detection Range PN-EN 10694:2002 | PN-EN 15936:2022-07","technique_en":"High-temperature combustion with IR detection","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"(5,0 - 500) g/kg"}],"search_zh":"土壤 总有机碳（TOC）含量 高温燃烧红外检测法 范围 PN-EN 10694:2002 | PN-EN 15936:2022-07","technique_zh":"高温燃烧红外检测法","test_object_zh":"土壤","methodology_zh":"总有机碳（TOC）含量"},{"_id":"6a8369ecaf14b9c0e7b1ddb7","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"Skład granulometryczny w zakresie wielkości cząstek (0,020 – 20,0) mm z podziałem na frakcje","parameters":[{"name":"Zakres","range":"(0,5 - 99,5) %"}],"technique":"Metoda sitowa","techniques":["Metoda sitowa"],"computed":[],"activity":"Skład granulometryczny w zakresie wielkości cząstek (0,020 – 20,0) mm z podziałem na frakcje\nZakres (0,5 - 99,5) %\nMetoda sitowa","reference":"PN-R-04032:1998 pkt. 3.3 | PN-EN ISO 17892-4:2017-01","norm_bases":["PN-R-04032:1998 pkt. 3.3","PN-EN ISO 17892-4:2017-01"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty Skład granulometryczny w zakresie wielkości cząstek (0,020 – 20,0) mm z podziałem na frakcje\nZakres (0,5 - 99,5) %\nMetoda sitowa PN-R-04032:1998 pkt. 3.3 | PN-EN ISO 17892-4:2017-01 Gleba, grunty Sklad granulometryczny w zakresie wielkosci czastek (0,020 – 20,0) mm z podzialem na frakcje\nZakres (0,5 - 99,5) %\nMetoda sitowa PN-R-04032:1998 pkt. 3.3 | PN-EN ISO 17892-4:2017-01","categories":["environment"],"row_index":405,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Particle size distribution in the particle size range (0,020 – 20,0) mm divided into fractions","parameters_en":[{"name":"Range","range":"(0,5 - 99,5) %"}],"search_en":"Soil, ground Particle size distribution in the particle size range (0,020 – 20,0) mm divided into fractions Sieve method Range PN-R-04032:1998 pkt. 3.3 | PN-EN ISO 17892-4:2017-01","technique_en":"Sieve method","test_object_en":"Soil, ground","parameters_zh":[{"name":"范围","range":"(0,5 - 99,5) %"}],"search_zh":"土壤、土体 筛析法 范围 PN-R-04032:1998 pkt. 3.3 | PN-EN ISO 17892-4:2017-01","test_object_zh":"土壤、土体","technique_zh":"筛析法"},{"_id":"6a8369ecaf14b9c0e7b1ddb8","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"Wodoprzepuszczalność - współczynnik filtracji","parameters":[{"name":"Zakres","range":"(1,0·10-10 - 1,0·10-5) m/s"}],"technique":"Metoda spadków hydraulicznych","techniques":["Metoda spadków hydraulicznych"],"computed":[],"activity":"Wodoprzepuszczalność - współczynnik filtracji\nZakres (1,0·10-10 - 1,0·10-5) m/s\nMetoda spadków hydraulicznych","reference":"PN-CEN ISO/TS 17892-11:2009 | PN-EN ISO 17892-11:2019-05","norm_bases":["PN-CEN ISO/TS 17892-11:2009","PN-EN ISO 17892-11:2019-05"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty Wodoprzepuszczalność - współczynnik filtracji\nZakres (1,0·10-10 - 1,0·10-5) m/s\nMetoda spadków hydraulicznych PN-CEN ISO/TS 17892-11:2009 | PN-EN ISO 17892-11:2019-05 Gleba, grunty Wodoprzepuszczalnosc - wspolczynnik filtracji\nZakres (1,0·10-10 - 1,0·10-5) m/s\nMetoda spadkow hydraulicznych PN-CEN ISO/TS 17892-11:2009 | PN-EN ISO 17892-11:2019-05","categories":["environment"],"row_index":406,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water permeability - coefficient of permeability","parameters_en":[{"name":"Range","range":"(1,0·10-10 - 1,0·10-5) m/s"}],"search_en":"Soil, ground Water permeability - coefficient of permeability Hydraulic gradient method Range PN-CEN ISO/TS 17892-11:2009 | PN-EN ISO 17892-11:2019-05","technique_en":"Hydraulic gradient method","test_object_en":"Soil, ground","parameters_zh":[{"name":"范围","range":"(1,0·10-10 - 1,0·10-5) m/s"}],"search_zh":"土壤、土体 透水性 － 渗透系数 水力坡降法 范围 PN-CEN ISO/TS 17892-11:2009 | PN-EN ISO 17892-11:2019-05","test_object_zh":"土壤、土体","technique_zh":"水力坡降法","methodology_zh":"透水性 － 渗透系数"},{"_id":"6a8369ecaf14b9c0e7b1ddb9","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"Wodoprzepuszczalność - współczynnik filtracji","parameters":[{"name":"Zakres","range":"(1,0·10-5 - 1,0·10-2) m/s"},{"name":"(z obliczeń na podstawie krzywej uziarnienia – wzór USBSC)"}],"technique":null,"techniques":[],"computed":[],"activity":"Wodoprzepuszczalność - współczynnik filtracji\nZakres:\nZakres (1,0·10-5 - 1,0·10-2) m/s\n(z obliczeń na podstawie krzywej uziarnienia – wzór USBSC)","reference":"PB-DAN-38 wersja 1 z dnia 11.08.2022 r.","norm_bases":["PB-DAN-38 wersja 1 z dnia 11.08.2022 r."],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty Wodoprzepuszczalność - współczynnik filtracji\nZakres:\nZakres (1,0·10-5 - 1,0·10-2) m/s\n(z obliczeń na podstawie krzywej uziarnienia – wzór USBSC) PB-DAN-38 wersja 1 z dnia 11.08.2022 r. Gleba, grunty Wodoprzepuszczalnosc - wspolczynnik filtracji\nZakres:\nZakres (1,0·10-5 - 1,0·10-2) m/s\n(z obliczen na podstawie krzywej uziarnienia – wzor USBSC) PB-DAN-38 wersja 1 z dnia 11.08.2022 r.","categories":["environment"],"row_index":407,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water permeability - coefficient of permeability","parameters_en":[{"name":"Range","range":"(1,0·10-5 - 1,0·10-2) m/s"},{"name":"(calculated from the particle size distribution curve – USBSC formula)"}],"search_en":"Soil, ground Water permeability - coefficient of permeability Range (calculated from the particle size distribution curve – USBSC formula) PB-DAN-38 wersja 1 z dnia 11.08.2022 r.","test_object_en":"Soil, ground","parameters_zh":[{"name":"范围","range":"(1,0·10-5 - 1,0·10-2) m/s"},{"name":"（依据颗粒级配曲线计算得出 － USBSC 公式）"}],"search_zh":"土壤、土体 透水性 － 渗透系数 范围 （依据颗粒级配曲线计算得出 － USBSC 公式） PB-DAN-38 wersja 1 z dnia 11.08.2022 r.","test_object_zh":"土壤、土体","methodology_zh":"透水性 － 渗透系数"},{"_id":"6a8369ecaf14b9c0e7b1ddba","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Gleba, Osady ściekowe","methodology":"Zawartość substancji organicznych","parameters":[{"name":"Zakres","range":"(0,1 - 99,5) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość substancji organicznych\nZakres (0,1 - 99,5) %\nMetoda wagowa","reference":"PN-EN 15935:2022-01","norm_bases":["PN-EN 15935:2022-01"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, Osady ściekowe Zawartość substancji organicznych\nZakres (0,1 - 99,5) %\nMetoda wagowa PN-EN 15935:2022-01 Gleba, Osady sciekowe Zawartosc substancji organicznych\nZakres (0,1 - 99,5) %\nMetoda wagowa PN-EN 15935:2022-01","categories":["water","environment"],"row_index":408,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of organic substances","parameters_en":[{"name":"Range","range":"(0,1 - 99,5) %"}],"search_en":"Soil, Sewage sludge Content of organic substances Gravimetric method Range PN-EN 15935:2022-01","technique_en":"Gravimetric method","test_object_en":"Soil, Sewage sludge","parameters_zh":[{"name":"范围","range":"(0,1 - 99,5) %"}],"search_zh":"土壤、污泥 有机物质含量 重量法 范围 PN-EN 15935:2022-01","technique_zh":"重量法","test_object_zh":"土壤、污泥","methodology_zh":"有机物质含量"},{"_id":"6a8369ecaf14b9c0e7b1ddbb","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Gleba, Osady ściekowe","methodology":"Zawartość substancji mineralnych (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość substancji mineralnych (z obliczeń)","reference":"PN-EN 15935:2022-01","norm_bases":["PN-EN 15935:2022-01"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, Osady ściekowe Zawartość substancji mineralnych (z obliczeń) PN-EN 15935:2022-01 Gleba, Osady sciekowe Zawartosc substancji mineralnych (z obliczen) PN-EN 15935:2022-01","categories":["water","environment"],"row_index":409,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mineral substance content (calculated)","search_en":"Soil, Sewage sludge Mineral substance content (calculated) PN-EN 15935:2022-01","test_object_en":"Soil, Sewage sludge","search_zh":"土壤、污泥 PN-EN 15935:2022-01","test_object_zh":"土壤、污泥"},{"_id":"6a8369ecaf14b9c0e7b1ddbc","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Gleba, Osady ściekowe","methodology":"Zawartość azotu amonowego","parameters":[{"name":"Zakres","range":"(0,10 - 10) %"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Zawartość azotu amonowego\nZakres (0,10 - 10) %\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN 14671:2007 | PN-EN ISO 11732:2007","norm_bases":["PN-EN 14671:2007","PN-EN ISO 11732:2007"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, Osady ściekowe Zawartość azotu amonowego\nZakres (0,10 - 10) %\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN 14671:2007 | PN-EN ISO 11732:2007 Gleba, Osady sciekowe Zawartosc azotu amonowego\nZakres (0,10 - 10) %\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN 14671:2007 | PN-EN ISO 11732:2007","categories":["water","environment"],"row_index":410,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen content","parameters_en":[{"name":"Range","range":"(0,10 - 10) %"}],"search_en":"Soil, Sewage sludge Ammonium nitrogen content Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN 14671:2007 | PN-EN ISO 11732:2007","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Soil, Sewage sludge","parameters_zh":[{"name":"范围","range":"(0,10 - 10) %"}],"search_zh":"土壤、污泥 氨氮含量 连续流动分析（CFA）分光光度检测法 范围 PN-EN 14671:2007 | PN-EN ISO 11732:2007","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"土壤、污泥","methodology_zh":"氨氮含量"},{"_id":"6a8369ecaf14b9c0e7b1ddbd","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Gleba, Osady ściekowe","methodology":"Zawartość azotu ogólnego","parameters":[{"name":"Zakres","range":"(1,00 - 20,0) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją TC","techniques":["Metoda wysokotemperaturowego spalania z detekcją TC"],"computed":[],"activity":"Zawartość azotu ogólnego\nZakres (1,00 - 20,0) %\nMetoda wysokotemperaturowego spalania z detekcją TC","reference":"PN-EN 16168:2012","norm_bases":["PN-EN 16168:2012"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, Osady ściekowe Zawartość azotu ogólnego\nZakres (1,00 - 20,0) %\nMetoda wysokotemperaturowego spalania z detekcją TC PN-EN 16168:2012 Gleba, Osady sciekowe Zawartosc azotu ogolnego\nZakres (1,00 - 20,0) %\nMetoda wysokotemperaturowego spalania z detekcja TC PN-EN 16168:2012","categories":["water","environment"],"row_index":411,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total nitrogen content","parameters_en":[{"name":"Range","range":"(1,00 - 20,0) %"}],"search_en":"Soil, Sewage sludge Total nitrogen content High-temperature combustion with TC detection Range PN-EN 16168:2012","technique_en":"High-temperature combustion with TC detection","test_object_en":"Soil, Sewage sludge","parameters_zh":[{"name":"范围","range":"(1,00 - 20,0) %"}],"search_zh":"土壤、污泥 总氮含量 高温燃烧总碳检测法 范围 PN-EN 16168:2012","test_object_zh":"土壤、污泥","technique_zh":"高温燃烧总碳检测法","methodology_zh":"总氮含量"},{"_id":"6a8369ecaf14b9c0e7b1ddbe","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Gleba, Osady ściekowe","methodology":"Zawartość rtęci","parameters":[{"name":"Zakres","range":"(0,005 - 10,00) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","techniques":["Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji"],"computed":[],"activity":"Zawartość rtęci\nZakres (0,005 - 10,00) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","reference":"PB-DAN-25 wersja 01 z dnia 16.02.2021 r.","norm_bases":["PB-DAN-25 wersja 01 z dnia 16.02.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, Osady ściekowe Zawartość rtęci\nZakres (0,005 - 10,00) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji PB-DAN-25 wersja 01 z dnia 16.02.2021 r. Gleba, Osady sciekowe Zawartosc rteci\nZakres (0,005 - 10,00) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z technika amalgamacji PB-DAN-25 wersja 01 z dnia 16.02.2021 r.","categories":["water","environment"],"row_index":412,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury content","parameters_en":[{"name":"Range","range":"(0,005 - 10,00) mg/kg"}],"search_en":"Soil, Sewage sludge Mercury content Atomic absorption spectrometry with amalgamation technique Range PB-DAN-25 wersja 01 z dnia 16.02.2021 r.","technique_en":"Atomic absorption spectrometry with amalgamation technique","test_object_en":"Soil, Sewage sludge","methodology_zh":"汞含量","parameters_zh":[{"name":"范围","range":"(0,005 - 10,00) mg/kg"}],"search_zh":"土壤、污泥 汞含量 原子吸收光谱法（汞齐化技术） 范围 PB-DAN-25 wersja 01 z dnia 16.02.2021 r.","technique_zh":"原子吸收光谱法（汞齐化技术）","test_object_zh":"土壤、污泥"},{"_id":"6a8369ecaf14b9c0e7b1ddbf","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Nawozy: - naturalne, - mineralne, - organiczne w tym kompost, - organiczno-mineralne, Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby, - stymulatory wzrostu, - podłoża do upraw","methodology":"pH - w H2O","parameters":[{"name":"Zakres","range":"2,0 - 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH - w H2O\nZakres 2,0 - 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Nawozy: - naturalne, - mineralne, - organiczne w tym kompost, - organiczno-mineralne, Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby, - stymulatory wzrostu, - podłoża do upraw pH - w H2O\nZakres 2,0 - 12,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 Nawozy: - naturalne, - mineralne, - organiczne w tym kompost, - organiczno-mineralne, Srodki wspomagajace uprawe roslin: - srodki poprawiajace wlasciwosci gleby, - stymulatory wzrostu, - podloza do upraw pH - w H2O\nZakres 2,0 - 12,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["other"],"row_index":413,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH - in H2O","parameters_en":[{"name":"Range","range":"2,0 - 12,0"}],"search_en":"Fertilisers: - natural, - mineral, - organic including compost, - organic-mineral, Plant cultivation aids: - soil improvers, - growth stimulants, - growing media pH - in H2O Potentiometric method Range PN-EN ISO 10390:2022-09","technique_en":"Potentiometric method","test_object_en":"Fertilisers: - natural, - mineral, - organic including compost, - organic-mineral, Plant cultivation aids: - soil improvers, - growth stimulants, - growing media","parameters_zh":[{"name":"范围","range":"2,0 - 12,0"}],"search_zh":"肥料：－ 农家肥，－ 矿物肥，－ 有机肥（含堆肥），－ 有机-矿物肥；植物栽培辅助制剂：－ 土壤改良剂，－ 生长调节剂，－ 栽培基质 pH - 于 H2O 中 电位法 范围 PN-EN ISO 10390:2022-09","technique_zh":"电位法","methodology_zh":"pH - 于 H2O 中","test_object_zh":"肥料：－ 农家肥，－ 矿物肥，－ 有机肥（含堆肥），－ 有机-矿物肥；植物栽培辅助制剂：－ 土壤改良剂，－ 生长调节剂，－ 栽培基质"},{"_id":"6a8369ecaf14b9c0e7b1ddc0","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Nawozy: - naturalne, - mineralne, - organiczne w tym kompost, - organiczno-mineralne, Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby, - stymulatory wzrostu, - podłoża do upraw","methodology":"Sucha masa / zawartość wody","parameters":[{"name":"Zakres","range":"(0,1 - 99,5) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha masa / zawartość wody\nZakres (0,1 - 99,5) %\nMetoda wagowa","reference":"PN-EN 15934:2013-02 z wył. p. 7, Metoda B","norm_bases":["PN-EN 15934:2013-02 z wył. p. 7, Metoda B"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Nawozy: - naturalne, - mineralne, - organiczne w tym kompost, - organiczno-mineralne, Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby, - stymulatory wzrostu, - podłoża do upraw Sucha masa / zawartość wody\nZakres (0,1 - 99,5) %\nMetoda wagowa PN-EN 15934:2013-02 z wył. p. 7, Metoda B Nawozy: - naturalne, - mineralne, - organiczne w tym kompost, - organiczno-mineralne, Srodki wspomagajace uprawe roslin: - srodki poprawiajace wlasciwosci gleby, - stymulatory wzrostu, - podloza do upraw Sucha masa / zawartosc wody\nZakres (0,1 - 99,5) %\nMetoda wagowa PN-EN 15934:2013-02 z wyl. p. 7, Metoda B","categories":["water"],"row_index":414,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry matter / water content","parameters_en":[{"name":"Range","range":"(0,1 - 99,5) %"}],"search_en":"Fertilisers: - natural, - mineral, - organic including compost, - organic-mineral, Plant cultivation aids: - soil improvers, - growth stimulants, - growing media Dry matter / water content Gravimetric method Range PN-EN 15934:2013-02 z wył. p. 7, Metoda B","technique_en":"Gravimetric method","test_object_en":"Fertilisers: - natural, - mineral, - organic including compost, - organic-mineral, Plant cultivation aids: - soil improvers, - growth stimulants, - growing media","parameters_zh":[{"name":"范围","range":"(0,1 - 99,5) %"}],"search_zh":"肥料：－ 农家肥，－ 矿物肥，－ 有机肥（含堆肥），－ 有机-矿物肥；植物栽培辅助制剂：－ 土壤改良剂，－ 生长调节剂，－ 栽培基质 干物质 / 水分含量 重量法 范围 PN-EN 15934:2013-02 z wył. p. 7, Metoda B","technique_zh":"重量法","methodology_zh":"干物质 / 水分含量","test_object_zh":"肥料：－ 农家肥，－ 矿物肥，－ 有机肥（含堆肥），－ 有机-矿物肥；植物栽培辅助制剂：－ 土壤改良剂，－ 生长调节剂，－ 栽培基质"},{"_id":"6a8369ecaf14b9c0e7b1ddc1","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Nawozy: - naturalne, - mineralne, - organiczne w tym kompost, - organiczno-mineralne, Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby, - stymulatory wzrostu, - podłoża do upraw","methodology":"Zawartość substancji organicznych","parameters":[{"name":"Zakres","range":"(0,1 - 99,5) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość substancji organicznych\nZakres (0,1 - 99,5) %\nMetoda wagowa","reference":"PN-EN 15935:2022-01","norm_bases":["PN-EN 15935:2022-01"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Nawozy: - naturalne, - mineralne, - organiczne w tym kompost, - organiczno-mineralne, Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby, - stymulatory wzrostu, - podłoża do upraw Zawartość substancji organicznych\nZakres (0,1 - 99,5) %\nMetoda wagowa PN-EN 15935:2022-01 Nawozy: - naturalne, - mineralne, - organiczne w tym kompost, - organiczno-mineralne, Srodki wspomagajace uprawe roslin: - srodki poprawiajace wlasciwosci gleby, - stymulatory wzrostu, - podloza do upraw Zawartosc substancji organicznych\nZakres (0,1 - 99,5) %\nMetoda wagowa PN-EN 15935:2022-01","categories":["other"],"row_index":415,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of organic substances","parameters_en":[{"name":"Range","range":"(0,1 - 99,5) %"}],"search_en":"Fertilisers: - natural, - mineral, - organic including compost, - organic-mineral, Plant cultivation aids: - soil improvers, - growth stimulants, - growing media Content of organic substances Gravimetric method Range PN-EN 15935:2022-01","technique_en":"Gravimetric method","test_object_en":"Fertilisers: - natural, - mineral, - organic including compost, - organic-mineral, Plant cultivation aids: - soil improvers, - growth stimulants, - growing media","parameters_zh":[{"name":"范围","range":"(0,1 - 99,5) %"}],"search_zh":"肥料：－ 农家肥，－ 矿物肥，－ 有机肥（含堆肥），－ 有机-矿物肥；植物栽培辅助制剂：－ 土壤改良剂，－ 生长调节剂，－ 栽培基质 有机物质含量 重量法 范围 PN-EN 15935:2022-01","technique_zh":"重量法","methodology_zh":"有机物质含量","test_object_zh":"肥料：－ 农家肥，－ 矿物肥，－ 有机肥（含堆肥），－ 有机-矿物肥；植物栽培辅助制剂：－ 土壤改良剂，－ 生长调节剂，－ 栽培基质"},{"_id":"6a8369ecaf14b9c0e7b1ddc2","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Nawozy: - naturalne, - mineralne, - organiczne w tym kompost, - organiczno-mineralne, Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby, - stymulatory wzrostu, - podłoża do upraw","methodology":"Zawartość substancji mineralnych (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość substancji mineralnych (z obliczeń)","reference":"PN-EN 15935:2022-01","norm_bases":["PN-EN 15935:2022-01"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Nawozy: - naturalne, - mineralne, - organiczne w tym kompost, - organiczno-mineralne, Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby, - stymulatory wzrostu, - podłoża do upraw Zawartość substancji mineralnych (z obliczeń) PN-EN 15935:2022-01 Nawozy: - naturalne, - mineralne, - organiczne w tym kompost, - organiczno-mineralne, Srodki wspomagajace uprawe roslin: - srodki poprawiajace wlasciwosci gleby, - stymulatory wzrostu, - podloza do upraw Zawartosc substancji mineralnych (z obliczen) PN-EN 15935:2022-01","categories":["other"],"row_index":416,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mineral substance content (calculated)","search_en":"Fertilisers: - natural, - mineral, - organic including compost, - organic-mineral, Plant cultivation aids: - soil improvers, - growth stimulants, - growing media Mineral substance content (calculated) PN-EN 15935:2022-01","test_object_en":"Fertilisers: - natural, - mineral, - organic including compost, - organic-mineral, Plant cultivation aids: - soil improvers, - growth stimulants, - growing media","search_zh":"肥料：－ 农家肥，－ 矿物肥，－ 有机肥（含堆肥），－ 有机-矿物肥；植物栽培辅助制剂：－ 土壤改良剂，－ 生长调节剂，－ 栽培基质 PN-EN 15935:2022-01","test_object_zh":"肥料：－ 农家肥，－ 矿物肥，－ 有机肥（含堆肥），－ 有机-矿物肥；植物栽培辅助制剂：－ 土壤改良剂，－ 生长调节剂，－ 栽培基质"},{"_id":"6a8369ecaf14b9c0e7b1ddc3","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Nawozy: - naturalne, - mineralne, - organiczne w tym kompost, - organiczno-mineralne, Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby, - stymulatory wzrostu, - podłoża do upraw","methodology":"Zawartość rtęci","parameters":[{"name":"Zakres","range":"(0,005 - 9,00) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","techniques":["Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji"],"computed":[],"activity":"Zawartość rtęci\nZakres (0,005 - 9,00) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","reference":"PB-DAN-25 wersja 01 z dnia 16.02.2021 r.","norm_bases":["PB-DAN-25 wersja 01 z dnia 16.02.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Nawozy: - naturalne, - mineralne, - organiczne w tym kompost, - organiczno-mineralne, Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby, - stymulatory wzrostu, - podłoża do upraw Zawartość rtęci\nZakres (0,005 - 9,00) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji PB-DAN-25 wersja 01 z dnia 16.02.2021 r. Nawozy: - naturalne, - mineralne, - organiczne w tym kompost, - organiczno-mineralne, Srodki wspomagajace uprawe roslin: - srodki poprawiajace wlasciwosci gleby, - stymulatory wzrostu, - podloza do upraw Zawartosc rteci\nZakres (0,005 - 9,00) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z technika amalgamacji PB-DAN-25 wersja 01 z dnia 16.02.2021 r.","categories":["other"],"row_index":417,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury content","parameters_en":[{"name":"Range","range":"(0,005 - 9,00) mg/kg"}],"search_en":"Fertilisers: - natural, - mineral, - organic including compost, - organic-mineral, Plant cultivation aids: - soil improvers, - growth stimulants, - growing media Mercury content Atomic absorption spectrometry with amalgamation technique Range PB-DAN-25 wersja 01 z dnia 16.02.2021 r.","technique_en":"Atomic absorption spectrometry with amalgamation technique","test_object_en":"Fertilisers: - natural, - mineral, - organic including compost, - organic-mineral, Plant cultivation aids: - soil improvers, - growth stimulants, - growing media","methodology_zh":"汞含量","parameters_zh":[{"name":"范围","range":"(0,005 - 9,00) mg/kg"}],"search_zh":"肥料：－ 农家肥，－ 矿物肥，－ 有机肥（含堆肥），－ 有机-矿物肥；植物栽培辅助制剂：－ 土壤改良剂，－ 生长调节剂，－ 栽培基质 汞含量 原子吸收光谱法（汞齐化技术） 范围 PB-DAN-25 wersja 01 z dnia 16.02.2021 r.","technique_zh":"原子吸收光谱法（汞齐化技术）","test_object_zh":"肥料：－ 农家肥，－ 矿物肥，－ 有机肥（含堆肥），－ 有机-矿物肥；植物栽培辅助制剂：－ 土壤改良剂，－ 生长调节剂，－ 栽培基质"},{"_id":"6a8369ecaf14b9c0e7b1ddc4","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Nawozy: - naturalne, - mineralne, - organiczne w tym kompost, - organiczno-mineralne, Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby, - stymulatory wzrostu, - podłoża do upraw","methodology":"Zawartość azotu ogólnego","parameters":[{"name":"Zakres","range":"(1,00 - 20,0) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją TC","techniques":["Metoda wysokotemperaturowego spalania z detekcją TC"],"computed":[],"activity":"Zawartość azotu ogólnego\nZakres (1,00 - 20,0) %\nMetoda wysokotemperaturowego spalania z detekcją TC","reference":"PN-EN 16168:2012","norm_bases":["PN-EN 16168:2012"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Nawozy: - naturalne, - mineralne, - organiczne w tym kompost, - organiczno-mineralne, Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby, - stymulatory wzrostu, - podłoża do upraw Zawartość azotu ogólnego\nZakres (1,00 - 20,0) %\nMetoda wysokotemperaturowego spalania z detekcją TC PN-EN 16168:2012 Nawozy: - naturalne, - mineralne, - organiczne w tym kompost, - organiczno-mineralne, Srodki wspomagajace uprawe roslin: - srodki poprawiajace wlasciwosci gleby, - stymulatory wzrostu, - podloza do upraw Zawartosc azotu ogolnego\nZakres (1,00 - 20,0) %\nMetoda wysokotemperaturowego spalania z detekcja TC PN-EN 16168:2012","categories":["other"],"row_index":418,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total nitrogen content","parameters_en":[{"name":"Range","range":"(1,00 - 20,0) %"}],"search_en":"Fertilisers: - natural, - mineral, - organic including compost, - organic-mineral, Plant cultivation aids: - soil improvers, - growth stimulants, - growing media Total nitrogen content High-temperature combustion with TC detection Range PN-EN 16168:2012","technique_en":"High-temperature combustion with TC detection","test_object_en":"Fertilisers: - natural, - mineral, - organic including compost, - organic-mineral, Plant cultivation aids: - soil improvers, - growth stimulants, - growing media","parameters_zh":[{"name":"范围","range":"(1,00 - 20,0) %"}],"search_zh":"肥料：－ 农家肥，－ 矿物肥，－ 有机肥（含堆肥），－ 有机-矿物肥；植物栽培辅助制剂：－ 土壤改良剂，－ 生长调节剂，－ 栽培基质 总氮含量 高温燃烧总碳检测法 范围 PN-EN 16168:2012","technique_zh":"高温燃烧总碳检测法","methodology_zh":"总氮含量","test_object_zh":"肥料：－ 农家肥，－ 矿物肥，－ 有机肥（含堆肥），－ 有机-矿物肥；植物栽培辅助制剂：－ 土壤改良剂，－ 生长调节剂，－ 栽培基质"},{"_id":"6a8369ecaf14b9c0e7b1ddc5","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Nawozy: - naturalne, - mineralne, - organiczne w tym kompost, - organiczno-mineralne, Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby, - stymulatory wzrostu, - podłoża do upraw","methodology":"Zawartość azotu amonowego","parameters":[{"name":"Zakres","range":"(0,10 - 10) %"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Zawartość azotu amonowego\nZakres (0,10 - 10) %\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN 14671:2007 | PN-EN ISO 11732:2007","norm_bases":["PN-EN 14671:2007","PN-EN ISO 11732:2007"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Nawozy: - naturalne, - mineralne, - organiczne w tym kompost, - organiczno-mineralne, Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby, - stymulatory wzrostu, - podłoża do upraw Zawartość azotu amonowego\nZakres (0,10 - 10) %\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN 14671:2007 | PN-EN ISO 11732:2007 Nawozy: - naturalne, - mineralne, - organiczne w tym kompost, - organiczno-mineralne, Srodki wspomagajace uprawe roslin: - srodki poprawiajace wlasciwosci gleby, - stymulatory wzrostu, - podloza do upraw Zawartosc azotu amonowego\nZakres (0,10 - 10) %\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN 14671:2007 | PN-EN ISO 11732:2007","categories":["other"],"row_index":419,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen content","parameters_en":[{"name":"Range","range":"(0,10 - 10) %"}],"search_en":"Fertilisers: - natural, - mineral, - organic including compost, - organic-mineral, Plant cultivation aids: - soil improvers, - growth stimulants, - growing media Ammonium nitrogen content Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN 14671:2007 | PN-EN ISO 11732:2007","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Fertilisers: - natural, - mineral, - organic including compost, - organic-mineral, Plant cultivation aids: - soil improvers, - growth stimulants, - growing media","parameters_zh":[{"name":"范围","range":"(0,10 - 10) %"}],"search_zh":"肥料：－ 农家肥，－ 矿物肥，－ 有机肥（含堆肥），－ 有机-矿物肥；植物栽培辅助制剂：－ 土壤改良剂，－ 生长调节剂，－ 栽培基质 氨氮含量 连续流动分析（CFA）分光光度检测法 范围 PN-EN 14671:2007 | PN-EN ISO 11732:2007","technique_zh":"连续流动分析（CFA）分光光度检测法","methodology_zh":"氨氮含量","test_object_zh":"肥料：－ 农家肥，－ 矿物肥，－ 有机肥（含堆肥），－ 有机-矿物肥；植物栽培辅助制剂：－ 土壤改良剂，－ 生长调节剂，－ 栽培基质"},{"_id":"6a8369ecaf14b9c0e7b1ddc6","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Środowisko pracy – próbki powietrza pobrane na filtry","methodology":"Zawartość pierwiastków","parameters":[{"name":"Glin metaliczny, glin proszek, Tritlenek glinu – w przeliczeniu na Al Wodorotlenek glinu w przeliczeniu na Al (0,010 - 5,00) mg w próbce Chrom metaliczny"},{"name":"Zakres","range":"(0,0050 - 1,00) mg w próbce"},{"name":"Mangan i jego związki nieorganiczne – w przeliczeniu na Mn (0,0025 - 0,40) mg w próbce Tlenki żelaza – w przeliczeniu na Fe (0,020 - 10,0) mg w próbce Kobalt i jego związki nieorganiczne"},{"name":"w przeliczeniu na Co (0,0010 - 0,50) mg w próbce Związki niklu w przeliczeniu na Ni (0,0005 - 0,50) mg w próbce Nikiel metaliczny (0,0005 - 0,50) mg w próbce Miedź i jej związki nieorganiczne - w przeliczeniu na Cu (0,0050 - 1,00) mg w próbce Tlenek cynku - w przeliczeniu na Zn (0,010 - 10,0) mg w próbce Arsen i jego związki nieorganiczne"},{"name":"w przeliczeniu na As (0,0005 - 0,50) mg w próbce Selen i jego związki, z wyjątkiem selanu - w przeliczeniu na Se (0,0050 - 0,50) mg w próbce Molibden i jego związki - w przeliczeniu na Mo (0,020 - 6,00 mg w próbce Srebro (0,0005 - 0,10) mg w próbce Kadm i jego związki nieorganiczne – w przeliczeniu na Cd (0,0001 - 0,050) mg w próbce Cyna i jej związki nieorganiczne, z wyjątkiem stannanu - w przeliczeniu na Sn (0,010 - 3,00) mg w próbce Bar i jego związki rozpuszczalne - w przeliczeniu na Ba (0,010 - 1,00) mg w próbce Tal i jego związki - w przeliczeniu na Tl (0,0050 - 0,25) mg w próbce Ołów i jego związki nieorganiczne - w przeliczeniu na Pb (0,0025 - 0,10) mg w próbce"}],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"computed":[],"activity":"Zawartość pierwiastków\nZakres:\nGlin metaliczny, glin proszek, Tritlenek glinu – w przeliczeniu na Al Wodorotlenek glinu w przeliczeniu na Al (0,010 - 5,00) mg w próbce Chrom metaliczny\nZakres (0,0050 - 1,00) mg w próbce\nMangan i jego związki nieorganiczne – w przeliczeniu na Mn (0,0025 - 0,40) mg w próbce Tlenki żelaza – w przeliczeniu na Fe (0,020 - 10,0) mg w próbce Kobalt i jego związki nieorganiczne\nw przeliczeniu na Co (0,0010 - 0,50) mg w próbce Związki niklu w przeliczeniu na Ni (0,0005 - 0,50) mg w próbce Nikiel metaliczny (0,0005 - 0,50) mg w próbce Miedź i jej związki nieorganiczne - w przeliczeniu na Cu (0,0050 - 1,00) mg w próbce Tlenek cynku - w przeliczeniu na Zn (0,010 - 10,0) mg w próbce Arsen i jego związki nieorganiczne\nw przeliczeniu na As (0,0005 - 0,50) mg w próbce Selen i jego związki, z wyjątkiem selanu - w przeliczeniu na Se (0,0050 - 0,50) mg w próbce Molibden i jego związki - w przeliczeniu na Mo (0,020 - 6,00 mg w próbce Srebro (0,0005 - 0,10) mg w próbce Kadm i jego związki nieorganiczne – w przeliczeniu na Cd (0,0001 - 0,050) mg w próbce Cyna i jej związki nieorganiczne, z wyjątkiem stannanu - w przeliczeniu na Sn (0,010 - 3,00) mg w próbce Bar i jego związki rozpuszczalne - w przeliczeniu na Ba (0,010 - 1,00) mg w próbce Tal i jego związki - w przeliczeniu na Tl (0,0050 - 0,25) mg w próbce Ołów i jego związki nieorganiczne - w przeliczeniu na Pb (0,0025 - 0,10) mg w próbce\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"ISO 15202-2:2020-05 | ISO 30011:2010","norm_bases":["ISO 15202-2:2020-05","ISO 30011:2010"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – próbki powietrza pobrane na filtry Zawartość pierwiastków\nZakres:\nGlin metaliczny, glin proszek, Tritlenek glinu – w przeliczeniu na Al Wodorotlenek glinu w przeliczeniu na Al (0,010 - 5,00) mg w próbce Chrom metaliczny\nZakres (0,0050 - 1,00) mg w próbce\nMangan i jego związki nieorganiczne – w przeliczeniu na Mn (0,0025 - 0,40) mg w próbce Tlenki żelaza – w przeliczeniu na Fe (0,020 - 10,0) mg w próbce Kobalt i jego związki nieorganiczne\nw przeliczeniu na Co (0,0010 - 0,50) mg w próbce Związki niklu w przeliczeniu na Ni (0,0005 - 0,50) mg w próbce Nikiel metaliczny (0,0005 - 0,50) mg w próbce Miedź i jej związki nieorganiczne - w przeliczeniu na Cu (0,0050 - 1,00) mg w próbce Tlenek cynku - w przeliczeniu na Zn (0,010 - 10,0) mg w próbce Arsen i jego związki nieorganiczne\nw przeliczeniu na As (0,0005 - 0,50) mg w próbce Selen i jego związki, z wyjątkiem selanu - w przeliczeniu na Se (0,0050 - 0,50) mg w próbce Molibden i jego związki - w przeliczeniu na Mo (0,020 - 6,00 mg w próbce Srebro (0,0005 - 0,10) mg w próbce Kadm i jego związki nieorganiczne – w przeliczeniu na Cd (0,0001 - 0,050) mg w próbce Cyna i jej związki nieorganiczne, z wyjątkiem stannanu - w przeliczeniu na Sn (0,010 - 3,00) mg w próbce Bar i jego związki rozpuszczalne - w przeliczeniu na Ba (0,010 - 1,00) mg w próbce Tal i jego związki - w przeliczeniu na Tl (0,0050 - 0,25) mg w próbce Ołów i jego związki nieorganiczne - w przeliczeniu na Pb (0,0025 - 0,10) mg w próbce\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) ISO 15202-2:2020-05 | ISO 30011:2010 Srodowisko pracy – probki powietrza pobrane na filtry Zawartosc pierwiastkow\nZakres:\nGlin metaliczny, glin proszek, Tritlenek glinu – w przeliczeniu na Al Wodorotlenek glinu w przeliczeniu na Al (0,010 - 5,00) mg w probce Chrom metaliczny\nZakres (0,0050 - 1,00) mg w probce\nMangan i jego zwiazki nieorganiczne – w przeliczeniu na Mn (0,0025 - 0,40) mg w probce Tlenki zelaza – w przeliczeniu na Fe (0,020 - 10,0) mg w probce Kobalt i jego zwiazki nieorganiczne\nw przeliczeniu na Co (0,0010 - 0,50) mg w probce Zwiazki niklu w przeliczeniu na Ni (0,0005 - 0,50) mg w probce Nikiel metaliczny (0,0005 - 0,50) mg w probce Miedz i jej zwiazki nieorganiczne - w przeliczeniu na Cu (0,0050 - 1,00) mg w probce Tlenek cynku - w przeliczeniu na Zn (0,010 - 10,0) mg w probce Arsen i jego zwiazki nieorganiczne\nw przeliczeniu na As (0,0005 - 0,50) mg w probce Selen i jego zwiazki, z wyjatkiem selanu - w przeliczeniu na Se (0,0050 - 0,50) mg w probce Molibden i jego zwiazki - w przeliczeniu na Mo (0,020 - 6,00 mg w probce Srebro (0,0005 - 0,10) mg w probce Kadm i jego zwiazki nieorganiczne – w przeliczeniu na Cd (0,0001 - 0,050) mg w probce Cyna i jej zwiazki nieorganiczne, z wyjatkiem stannanu - w przeliczeniu na Sn (0,010 - 3,00) mg w probce Bar i jego zwiazki rozpuszczalne - w przeliczeniu na Ba (0,010 - 1,00) mg w probce Tal i jego zwiazki - w przeliczeniu na Tl (0,0050 - 0,25) mg w probce Olow i jego zwiazki nieorganiczne - w przeliczeniu na Pb (0,0025 - 0,10) mg w probce\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) ISO 15202-2:2020-05 | ISO 30011:2010","categories":["materials","environment"],"row_index":420,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element content","parameters_en":[{"name":"Metallic aluminium, aluminium powder, Aluminium trioxide – expressed as Al Aluminium hydroxide expressed as Al (0,010 - 5,00) mg in sample Metallic chromium"},{"name":"Range","range":"(0,0050 - 1,00) mg w próbce"},{"name":"Manganese and its inorganic compounds – expressed as Mn (0,0025 - 0,40) mg in sample Iron oxides – expressed as Fe (0,020 - 10,0) mg in sample Cobalt and its inorganic compounds"},{"name":"calculated as Co (0,0010 - 0,50) mg per sample Nickel compounds calculated as Ni (0,0005 - 0,50) mg per sample Metallic nickel (0,0005 - 0,50) mg per sample Copper and its inorganic compounds - calculated as Cu (0,0050 - 1,00) mg per sample Zinc oxide - calculated as Zn (0,010 - 10,0) mg per sample Arsenic and its inorganic compounds"},{"name":"calculated as As (0,0005 - 0,50) mg per sample Selenium and its compounds, excluding selane - calculated as Se (0,0050 - 0,50) mg per sample Molybdenum and its compounds - calculated as Mo (0,020 - 6,00 mg per sample Silver (0,0005 - 0,10) mg per sample Cadmium and its inorganic compounds – calculated as Cd (0,0001 - 0,050) mg per sample Tin and its inorganic compounds, excluding stannane - calculated as Sn (0,010 - 3,00) mg per sample Barium and its soluble compounds - calculated as Ba (0,010 - 1,00) mg per sample Thallium and its compounds - calculated as Tl (0,0050 - 0,25) mg per sample Lead and its inorganic compounds - calculated as Pb (0,0025 - 0,10) mg per sample"}],"search_en":"Workplace environment – air samples collected on filters Element content Inductively coupled plasma mass spectrometry (ICP-MS) Metallic aluminium, aluminium powder, Aluminium trioxide – expressed as Al Aluminium hydroxide expressed as Al (0,010 - 5,00) mg in sample Metallic chromium Range Manganese and its inorganic compounds – expressed as Mn (0,0025 - 0,40) mg in sample Iron oxides – expressed as Fe (0,020 - 10,0) mg in sample Cobalt and its inorganic compounds calculated as Co (0,0010 - 0,50) mg per sample Nickel compounds calculated as Ni (0,0005 - 0,50) mg per sample Metallic nickel (0,0005 - 0,50) mg per sample Copper and its inorganic compounds - calculated as Cu (0,0050 - 1,00) mg per sample Zinc oxide - calculated as Zn (0,010 - 10,0) mg per sample Arsenic and its inorganic compounds calculated as As (0,0005 - 0,50) mg per sample Selenium and its compounds, excluding selane - calculated as Se (0,0050 - 0,50) mg per sample Molybdenum and its compounds - calculated as Mo (0,020 - 6,00 mg per sample Silver (0,0005 - 0,10) mg per sample Cadmium and its inorganic compounds – calculated as Cd (0,0001 - 0,050) mg per sample Tin and its inorganic compounds, excluding stannane - calculated as Sn (0,010 - 3,00) mg per sample Barium and its soluble compounds - calculated as Ba (0,010 - 1,00) mg per sample Thallium and its compounds - calculated as Tl (0,0050 - 0,25) mg per sample Lead and its inorganic compounds - calculated as Pb (0,0025 - 0,10) mg per sample ISO 15202-2:2020-05 | ISO 30011:2010","technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","test_object_en":"Workplace environment – air samples collected on filters","methodology_zh":"元素含量","parameters_zh":[{"name":"Glin metaliczny, glin proszek, Tritlenek glinu – w przeliczeniu na Al Wodorotlenek glinu w przeliczeniu na Al (0,010 - 5,00) mg w próbce Chrom metaliczny"},{"name":"范围","range":"(0,0050 - 1,00) mg w próbce"},{"name":"Mangan i jego związki nieorganiczne – w przeliczeniu na Mn (0,0025 - 0,40) mg w próbce Tlenki żelaza – w przeliczeniu na Fe (0,020 - 10,0) mg w próbce Kobalt i jego związki nieorganiczne"},{"name":"w przeliczeniu na Co (0,0010 - 0,50) mg w próbce Związki niklu w przeliczeniu na Ni (0,0005 - 0,50) mg w próbce Nikiel metaliczny (0,0005 - 0,50) mg w próbce Miedź i jej związki nieorganiczne - w przeliczeniu na Cu (0,0050 - 1,00) mg w próbce Tlenek cynku - w przeliczeniu na Zn (0,010 - 10,0) mg w próbce Arsen i jego związki nieorganiczne"},{"name":"w przeliczeniu na As (0,0005 - 0,50) mg w próbce Selen i jego związki, z wyjątkiem selanu - w przeliczeniu na Se (0,0050 - 0,50) mg w próbce Molibden i jego związki - w przeliczeniu na Mo (0,020 - 6,00 mg w próbce Srebro (0,0005 - 0,10) mg w próbce Kadm i jego związki nieorganiczne – w przeliczeniu na Cd (0,0001 - 0,050) mg w próbce Cyna i jej związki nieorganiczne, z wyjątkiem stannanu - w przeliczeniu na Sn (0,010 - 3,00) mg w próbce Bar i jego związki rozpuszczalne - w przeliczeniu na Ba (0,010 - 1,00) mg w próbce Tal i jego związki - w przeliczeniu na Tl (0,0050 - 0,25) mg w próbce Ołów i jego związki nieorganiczne - w przeliczeniu na Pb (0,0025 - 0,10) mg w próbce"}],"search_zh":"工作场所环境 — 用滤膜采集的空气样品 元素含量 电感耦合等离子体质谱法（ICP-MS） 范围 ISO 15202-2:2020-05 | ISO 30011:2010","technique_zh":"电感耦合等离子体质谱法（ICP-MS）","test_object_zh":"工作场所环境 — 用滤膜采集的空气样品"},{"_id":"6a8369ecaf14b9c0e7b1ddc7","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Środowisko pracy – próbki powietrza pobrane na filtry","methodology":"Zawartość pierwiastków i ich związków","parameters":[{"name":"Sód (0,010 - 0,50) mg w próbce Wodorotlenek sodu"},{"name":"Zakres","range":"(0,018 - 0,86) mg w próbce"},{"name":"Potas (0,010 - 1,00) mg w próbce Wodorotlenek potasu (0,015 - 1,43) mg w próbce Magnez (0,010 - 10,0) mg w próbce Tlenek magnezu (0,017 - 16,5) mg w próbce Wanad (0,0010 - 0,10) mg w próbce Pentatlenek wanadu (0,0018 - 0,17) mg w próbce Wapń (0,025 – 3,00) mg w próbce Tlenek wapnia (0,035 - 4,19) mg w próbce Wodorotlenek wapnia (0,065 - 7,76) mg w próbce"}],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"computed":[],"activity":"Zawartość pierwiastków i ich związków\nZakres:\nSód (0,010 - 0,50) mg w próbce Wodorotlenek sodu\nZakres (0,018 - 0,86) mg w próbce\nPotas (0,010 - 1,00) mg w próbce Wodorotlenek potasu (0,015 - 1,43) mg w próbce Magnez (0,010 - 10,0) mg w próbce Tlenek magnezu (0,017 - 16,5) mg w próbce Wanad (0,0010 - 0,10) mg w próbce Pentatlenek wanadu (0,0018 - 0,17) mg w próbce Wapń (0,025 – 3,00) mg w próbce Tlenek wapnia (0,035 - 4,19) mg w próbce Wodorotlenek wapnia (0,065 - 7,76) mg w próbce\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"ISO 15202-2:2020-05 | ISO 30011:2010","norm_bases":["ISO 15202-2:2020-05","ISO 30011:2010"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – próbki powietrza pobrane na filtry Zawartość pierwiastków i ich związków\nZakres:\nSód (0,010 - 0,50) mg w próbce Wodorotlenek sodu\nZakres (0,018 - 0,86) mg w próbce\nPotas (0,010 - 1,00) mg w próbce Wodorotlenek potasu (0,015 - 1,43) mg w próbce Magnez (0,010 - 10,0) mg w próbce Tlenek magnezu (0,017 - 16,5) mg w próbce Wanad (0,0010 - 0,10) mg w próbce Pentatlenek wanadu (0,0018 - 0,17) mg w próbce Wapń (0,025 – 3,00) mg w próbce Tlenek wapnia (0,035 - 4,19) mg w próbce Wodorotlenek wapnia (0,065 - 7,76) mg w próbce\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) ISO 15202-2:2020-05 | ISO 30011:2010 Srodowisko pracy – probki powietrza pobrane na filtry Zawartosc pierwiastkow i ich zwiazkow\nZakres:\nSod (0,010 - 0,50) mg w probce Wodorotlenek sodu\nZakres (0,018 - 0,86) mg w probce\nPotas (0,010 - 1,00) mg w probce Wodorotlenek potasu (0,015 - 1,43) mg w probce Magnez (0,010 - 10,0) mg w probce Tlenek magnezu (0,017 - 16,5) mg w probce Wanad (0,0010 - 0,10) mg w probce Pentatlenek wanadu (0,0018 - 0,17) mg w probce Wapn (0,025 – 3,00) mg w probce Tlenek wapnia (0,035 - 4,19) mg w probce Wodorotlenek wapnia (0,065 - 7,76) mg w probce\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) ISO 15202-2:2020-05 | ISO 30011:2010","categories":["environment"],"row_index":421,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of elements and their compounds","parameters_en":[{"name":"Sodium (0,010 - 0,50) mg per sample Sodium hydroxide"},{"name":"Range","range":"(0,018 - 0,86) mg w próbce"},{"name":"Potassium (0,010 - 1,00) mg in sample Potassium hydroxide (0,015 - 1,43) mg in sample Magnesium (0,010 - 10,0) mg in sample Magnesium oxide (0,017 - 16,5) mg in sample Vanadium (0,0010 - 0,10) mg in sample Vanadium pentoxide (0,0018 - 0,17) mg in sample Calcium (0,025 – 3,00) mg in sample Calcium oxide (0,035 - 4,19) mg in sample Calcium hydroxide (0,065 - 7,76) mg in sample"}],"search_en":"Workplace environment – air samples collected on filters Content of elements and their compounds Inductively coupled plasma mass spectrometry (ICP-MS) Sodium (0,010 - 0,50) mg per sample Sodium hydroxide Range Potassium (0,010 - 1,00) mg in sample Potassium hydroxide (0,015 - 1,43) mg in sample Magnesium (0,010 - 10,0) mg in sample Magnesium oxide (0,017 - 16,5) mg in sample Vanadium (0,0010 - 0,10) mg in sample Vanadium pentoxide (0,0018 - 0,17) mg in sample Calcium (0,025 – 3,00) mg in sample Calcium oxide (0,035 - 4,19) mg in sample Calcium hydroxide (0,065 - 7,76) mg in sample ISO 15202-2:2020-05 | ISO 30011:2010","technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","test_object_en":"Workplace environment – air samples collected on filters","parameters_zh":[{"name":"Sód (0,010 - 0,50) mg w próbce Wodorotlenek sodu"},{"name":"范围","range":"(0,018 - 0,86) mg w próbce"},{"name":"Potas (0,010 - 1,00) mg w próbce Wodorotlenek potasu (0,015 - 1,43) mg w próbce Magnez (0,010 - 10,0) mg w próbce Tlenek magnezu (0,017 - 16,5) mg w próbce Wanad (0,0010 - 0,10) mg w próbce Pentatlenek wanadu (0,0018 - 0,17) mg w próbce Wapń (0,025 – 3,00) mg w próbce Tlenek wapnia (0,035 - 4,19) mg w próbce Wodorotlenek wapnia (0,065 - 7,76) mg w próbce"}],"search_zh":"工作场所环境 — 用滤膜采集的空气样品 电感耦合等离子体质谱法（ICP-MS） 范围 ISO 15202-2:2020-05 | ISO 30011:2010","technique_zh":"电感耦合等离子体质谱法（ICP-MS）","test_object_zh":"工作场所环境 — 用滤膜采集的空气样品"},{"_id":"6a8369ecaf14b9c0e7b1ddc8","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Środowisko pracy – próbki powietrza pobrane do roztworu pochłaniającego","methodology":"Zawartość chloru","parameters":[{"name":"Zakres","range":"(0,5 - 4,0) μg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość chloru\nZakres (0,5 - 4,0) μg w próbce\nMetoda spektrofotometryczna","reference":"PN-75/Z-04037/03","norm_bases":["PN-75/Z-04037/03"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – próbki powietrza pobrane do roztworu pochłaniającego Zawartość chloru\nZakres (0,5 - 4,0) μg w próbce\nMetoda spektrofotometryczna PN-75/Z-04037/03 Srodowisko pracy – probki powietrza pobrane do roztworu pochlaniajacego Zawartosc chloru\nZakres (0,5 - 4,0) μg w probce\nMetoda spektrofotometryczna PN-75/Z-04037/03","categories":["environment"],"row_index":422,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chlorine content","parameters_en":[{"name":"Range","range":"(0,5 - 4,0) μg w próbce"}],"search_en":"Workplace environment – air samples collected into an absorbing solution Chlorine content Spectrophotometric method Range PN-75/Z-04037/03","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment – air samples collected into an absorbing solution","parameters_zh":[{"name":"范围","range":"(0,5 - 4,0) μg w próbce"}],"search_zh":"氯含量 分光光度法 范围 PN-75/Z-04037/03","technique_zh":"分光光度法","methodology_zh":"氯含量"},{"_id":"6a8369ecaf14b9c0e7b1ddc9","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Środowisko pracy – próbki powietrza pobrane na filtry","methodology":"Zawartość krystalicznej krzemionki (kwarc, krystobalit) – frakcja respirabilna","parameters":[{"name":"Zakres","range":"(0,005 - 0,40) mg w próbce"},{"name":"Metoda spektrofotometrii w zakresie podczerwieni z transformacją Fouriera (FT-IR)"}],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość krystalicznej krzemionki (kwarc, krystobalit) – frakcja respirabilna\nZakres:\nZakres (0,005 - 0,40) mg w próbce\nMetoda spektrofotometrii w zakresie podczerwieni z transformacją Fouriera (FT-IR)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2012, nr 4(74) s. 117-130 | PB-DAN-03 wersja 01 z dnia 31.01.2020 r.","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2012, nr 4(74) s. 117-130","PB-DAN-03 wersja 01 z dnia 31.01.2020 r."],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – próbki powietrza pobrane na filtry Zawartość krystalicznej krzemionki (kwarc, krystobalit) – frakcja respirabilna\nZakres:\nZakres (0,005 - 0,40) mg w próbce\nMetoda spektrofotometrii w zakresie podczerwieni z transformacją Fouriera (FT-IR) Podstawy i Metody Oceny Środowiska Pracy 2012, nr 4(74) s. 117-130 | PB-DAN-03 wersja 01 z dnia 31.01.2020 r. Srodowisko pracy – probki powietrza pobrane na filtry Zawartosc krystalicznej krzemionki (kwarc, krystobalit) – frakcja respirabilna\nZakres:\nZakres (0,005 - 0,40) mg w probce\nMetoda spektrofotometrii w zakresie podczerwieni z transformacja Fouriera (FT-IR) Podstawy i Metody Oceny Srodowiska Pracy 2012, nr 4(74) s. 117-130 | PB-DAN-03 wersja 01 z dnia 31.01.2020 r.","categories":["environment"],"row_index":423,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Crystalline silica content (quartz, cristobalite) – respirable fraction","parameters_en":[{"name":"Range","range":"(0,005 - 0,40) mg w próbce"},{"name":"Metoda spektrofotometrii w zakresie podczerwieni z transformacją Fouriera (FT-IR)"}],"search_en":"Workplace environment – air samples collected on filters Crystalline silica content (quartz, cristobalite) – respirable fraction Range Podstawy i Metody Oceny Środowiska Pracy 2012, nr 4(74) s. 117-130 | PB-DAN-03 wersja 01 z dnia 31.01.2020 r.","test_object_en":"Workplace environment – air samples collected on filters","parameters_zh":[{"name":"范围","range":"(0,005 - 0,40) mg w próbce"},{"name":"Metoda spektrofotometrii w zakresie podczerwieni z transformacją Fouriera (FT-IR)"}],"search_zh":"工作场所环境 — 用滤膜采集的空气样品 范围 Podstawy i Metody Oceny Środowiska Pracy 2012, nr 4(74) s. 117-130 | PB-DAN-03 wersja 01 z dnia 31.01.2020 r.","test_object_zh":"工作场所环境 — 用滤膜采集的空气样品"},{"_id":"6a8369ecaf14b9c0e7b1ddca","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach) E, Woda do spożycia przez ludzi E, Ścieki E","methodology":"Stężenie /zawartość pierwiastków","parameters":[],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"computed":[],"activity":"Stężenie /zawartość pierwiastków\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"PN-EN ISO 17294 | PB-DAN-26","norm_bases":["PN-EN ISO 17294","PB-DAN-26"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Woda (w tym woda na pływalniach) E, Woda do spożycia przez ludzi E, Ścieki E Stężenie /zawartość pierwiastków\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) PN-EN ISO 17294 | PB-DAN-26 Woda (w tym woda na plywalniach) E, Woda do spozycia przez ludzi E, Scieki E Stezenie /zawartosc pierwiastkow\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) PN-EN ISO 17294 | PB-DAN-26","categories":["water"],"row_index":424,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of elements","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Concentration / content of elements Inductively coupled plasma mass spectrometry (ICP-MS) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PN-EN ISO 17294 | PB-DAN-26","technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"电感耦合等离子体质谱法（ICP-MS） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PN-EN ISO 17294 | PB-DAN-26","technique_zh":"电感耦合等离子体质谱法（ICP-MS）"},{"_id":"6a8369ecaf14b9c0e7b1ddcb","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Osady E, Komposty E, Środki wspomagające uprawę roślin E, Nawozy E, Gleba, grunty E","methodology":"Zawartość pierwiastków","parameters":[],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"computed":[],"activity":"Zawartość pierwiastków\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"PN-EN ISO 16965","norm_bases":["PN-EN ISO 16965"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Osady E, Komposty E, Środki wspomagające uprawę roślin E, Nawozy E, Gleba, grunty E Zawartość pierwiastków\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) PN-EN ISO 16965 Osady E, Komposty E, Srodki wspomagajace uprawe roslin E, Nawozy E, Gleba, grunty E Zawartosc pierwiastkow\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) PN-EN ISO 16965","categories":["water","environment"],"row_index":425,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Element content Inductively coupled plasma mass spectrometry (ICP-MS) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PN-EN ISO 16965","technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","methodology_zh":"元素含量","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"元素含量 电感耦合等离子体质谱法（ICP-MS） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PN-EN ISO 16965","technique_zh":"电感耦合等离子体质谱法（ICP-MS）"},{"_id":"6a8369ecaf14b9c0e7b1ddcc","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Odpady kod: 02 01 03, 02 03 01, 02 03 80, 10 01 01, 17 01 07, 17 01 80, 17 01 81, 17 01 82, 17 03 02, 17 03 80, 17 06 04, 17 09 04, 19 01 12, 19 06 04, 19 08 02, 19 09 01, 19 09 02, 19 12 09, 20 03 06, Odpady DAB-11: - Odpady z przetwarzania odpadów (VI) - Osady ściekowe (IX) - Tworzywa sztuczne (XXV) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII)","methodology":"pH 1,4,5","parameters":[{"name":"Zakres","range":"2,0 - 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH 1,4,5\nZakres 2,0 - 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012 | PN-EN 12457-4:2006","norm_bases":["PN-EN ISO 10523:2012","PN-EN 12457-4:2006"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: 1 - Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 roku w sprawie w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. z 2015, poz. 1277) 2 - Rozporządzeniem Ministra Środowiska z dnia 28 grudnia 2011 roku w sprawie w sprawie podziemnych składowisk odpadów (Dz. U. z 2011 nr 298, poz. 1771) 3 - Rozporządzenie Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (DZ. U. z 2017, poz. 2490) 4 - Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2023. poz. 23) 5 - Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 roku w sprawie procesu R10 (Dz. U. z 2015, poz. 132) | Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. | Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11","flexible":false,"search_text":"Odpady kod: 02 01 03, 02 03 01, 02 03 80, 10 01 01, 17 01 07, 17 01 80, 17 01 81, 17 01 82, 17 03 02, 17 03 80, 17 06 04, 17 09 04, 19 01 12, 19 06 04, 19 08 02, 19 09 01, 19 09 02, 19 12 09, 20 03 06, Odpady DAB-11: - Odpady z przetwarzania odpadów (VI) - Osady ściekowe (IX) - Tworzywa sztuczne (XXV) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII) pH 1,4,5\nZakres 2,0 - 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 | PN-EN 12457-4:2006 Odpady kod: 02 01 03, 02 03 01, 02 03 80, 10 01 01, 17 01 07, 17 01 80, 17 01 81, 17 01 82, 17 03 02, 17 03 80, 17 06 04, 17 09 04, 19 01 12, 19 06 04, 19 08 02, 19 09 01, 19 09 02, 19 12 09, 20 03 06, Odpady DAB-11: - Odpady z przetwarzania odpadow (VI) - Osady sciekowe (IX) - Tworzywa sztuczne (XXV) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII) pH 1,4,5\nZakres 2,0 - 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 | PN-EN 12457-4:2006","categories":["water","environment","materials"],"row_index":426,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH 1,4,5","parameters_en":[{"name":"Range","range":"2,0 - 12,0"}],"search_en":"pH 1,4,5 Potentiometric method Range PN-EN ISO 10523:2012 | PN-EN 12457-4:2006","technique_en":"Potentiometric method","parameters_zh":[{"name":"范围","range":"2,0 - 12,0"}],"search_zh":"电位法 范围 PN-EN ISO 10523:2012 | PN-EN 12457-4:2006","technique_zh":"电位法"},{"_id":"6a8369ecaf14b9c0e7b1ddcd","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Odpady kod: 02 01 03, 02 03 01, 02 03 80, 10 01 01, 17 01 07, 17 01 80, 17 01 81, 17 01 82, 17 03 02, 17 03 80, 17 06 04, 17 09 04, 19 01 12, 19 06 04, 19 08 02, 19 09 01, 19 09 02, 19 12 09, 20 03 06, Odpady DAB-11: - Odpady z przetwarzania odpadów (VI) - Osady ściekowe (IX) - Tworzywa sztuczne (XXV) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII)","methodology":"Indeks fenolowy (wskaźnik fenolowy) 1,2","parameters":[{"name":"Zakres","range":"(0,002 - 10,0) mg/l"},{"name":"Zakres","range":"(0,02 - 100) mg/kg"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Indeks fenolowy (wskaźnik fenolowy) 1,2\nZakres:\nZakres (0,002 - 10,0) mg/l\nZakres (0,02 - 100) mg/kg\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"P N - EN ISO 14402:2004 | PN-EN 12457-4:2006","norm_bases":["P N - EN ISO 14402:2004","PN-EN 12457-4:2006"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: 1 - Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 roku w sprawie w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. z 2015, poz. 1277) 2 - Rozporządzeniem Ministra Środowiska z dnia 28 grudnia 2011 roku w sprawie w sprawie podziemnych składowisk odpadów (Dz. U. z 2011 nr 298, poz. 1771) 3 - Rozporządzenie Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (DZ. U. z 2017, poz. 2490) 4 - Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2023. poz. 23) 5 - Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 roku w sprawie procesu R10 (Dz. U. z 2015, poz. 132) | Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. | Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11","flexible":false,"search_text":"Odpady kod: 02 01 03, 02 03 01, 02 03 80, 10 01 01, 17 01 07, 17 01 80, 17 01 81, 17 01 82, 17 03 02, 17 03 80, 17 06 04, 17 09 04, 19 01 12, 19 06 04, 19 08 02, 19 09 01, 19 09 02, 19 12 09, 20 03 06, Odpady DAB-11: - Odpady z przetwarzania odpadów (VI) - Osady ściekowe (IX) - Tworzywa sztuczne (XXV) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII) Indeks fenolowy (wskaźnik fenolowy) 1,2\nZakres:\nZakres (0,002 - 10,0) mg/l\nZakres (0,02 - 100) mg/kg\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną P N - EN ISO 14402:2004 | PN-EN 12457-4:2006 Odpady kod: 02 01 03, 02 03 01, 02 03 80, 10 01 01, 17 01 07, 17 01 80, 17 01 81, 17 01 82, 17 03 02, 17 03 80, 17 06 04, 17 09 04, 19 01 12, 19 06 04, 19 08 02, 19 09 01, 19 09 02, 19 12 09, 20 03 06, Odpady DAB-11: - Odpady z przetwarzania odpadow (VI) - Osady sciekowe (IX) - Tworzywa sztuczne (XXV) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII) Indeks fenolowy (wskaznik fenolowy) 1,2\nZakres:\nZakres (0,002 - 10,0) mg/l\nZakres (0,02 - 100) mg/kg\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna P N - EN ISO 14402:2004 | PN-EN 12457-4:2006","categories":["water","environment","materials"],"row_index":427,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,002 - 10,0) mg/l"},{"name":"Range","range":"(0,02 - 100) mg/kg"}],"search_en":"Continuous flow analysis (CFA) with spectrophotometric detection Range Range P N - EN ISO 14402:2004 | PN-EN 12457-4:2006","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","parameters_zh":[{"name":"范围","range":"(0,002 - 10,0) mg/l"},{"name":"范围","range":"(0,02 - 100) mg/kg"}],"search_zh":"连续流动分析（CFA）分光光度检测法 范围 范围 P N - EN ISO 14402:2004 | PN-EN 12457-4:2006","technique_zh":"连续流动分析（CFA）分光光度检测法"},{"_id":"6a8369ecaf14b9c0e7b1ddce","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Odpady kod: 02 01 03, 02 03 01, 02 03 80, 10 01 01, 17 01 07, 17 01 80, 17 01 81, 17 01 82, 17 03 02, 17 03 80, 17 06 04, 17 09 04, 19 01 12, 19 06 04, 19 08 02, 19 09 01, 19 09 02, 19 12 09, 20 03 06, Odpady DAB-11: - Odpady z przetwarzania odpadów (VI) - Osady ściekowe (IX) - Tworzywa sztuczne (XXV) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII)","methodology":"Zawartość ogólnego węgla 1,2 organicznego (OWO; TOC), rozpuszczonego węgla organicznego (RWO; DOC)","parameters":[{"name":"Zakres","range":"(1,0 - 5000) mg/l C"},{"name":"Zakres","range":"(10 - 50000) mg/kg"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość ogólnego węgla 1,2 organicznego (OWO; TOC), rozpuszczonego węgla organicznego (RWO; DOC)\nZakres:\nZakres (1,0 - 5000) mg/l C\nZakres (10 - 50000) mg/kg\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN 1484:1999 | PN-EN 12457-4:2006","norm_bases":["PN-EN 1484:1999","PN-EN 12457-4:2006"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: 1 - Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 roku w sprawie w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. z 2015, poz. 1277) 2 - Rozporządzeniem Ministra Środowiska z dnia 28 grudnia 2011 roku w sprawie w sprawie podziemnych składowisk odpadów (Dz. U. z 2011 nr 298, poz. 1771) 3 - Rozporządzenie Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (DZ. U. z 2017, poz. 2490) 4 - Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2023. poz. 23) 5 - Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 roku w sprawie procesu R10 (Dz. U. z 2015, poz. 132) | Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. | Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11","flexible":false,"search_text":"Odpady kod: 02 01 03, 02 03 01, 02 03 80, 10 01 01, 17 01 07, 17 01 80, 17 01 81, 17 01 82, 17 03 02, 17 03 80, 17 06 04, 17 09 04, 19 01 12, 19 06 04, 19 08 02, 19 09 01, 19 09 02, 19 12 09, 20 03 06, Odpady DAB-11: - Odpady z przetwarzania odpadów (VI) - Osady ściekowe (IX) - Tworzywa sztuczne (XXV) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII) Zawartość ogólnego węgla 1,2 organicznego (OWO; TOC), rozpuszczonego węgla organicznego (RWO; DOC)\nZakres:\nZakres (1,0 - 5000) mg/l C\nZakres (10 - 50000) mg/kg\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN 1484:1999 | PN-EN 12457-4:2006 Odpady kod: 02 01 03, 02 03 01, 02 03 80, 10 01 01, 17 01 07, 17 01 80, 17 01 81, 17 01 82, 17 03 02, 17 03 80, 17 06 04, 17 09 04, 19 01 12, 19 06 04, 19 08 02, 19 09 01, 19 09 02, 19 12 09, 20 03 06, Odpady DAB-11: - Odpady z przetwarzania odpadow (VI) - Osady sciekowe (IX) - Tworzywa sztuczne (XXV) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII) Zawartosc ogolnego wegla 1,2 organicznego (OWO; TOC), rozpuszczonego wegla organicznego (RWO; DOC)\nZakres:\nZakres (1,0 - 5000) mg/l C\nZakres (10 - 50000) mg/kg\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN 1484:1999 | PN-EN 12457-4:2006","categories":["water","environment","materials"],"row_index":428,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(1,0 - 5000) mg/l C"},{"name":"Range","range":"(10 - 50000) mg/kg"}],"search_en":"High-temperature combustion with IR detection Range Range PN-EN 1484:1999 | PN-EN 12457-4:2006","technique_en":"High-temperature combustion with IR detection","parameters_zh":[{"name":"范围","range":"(1,0 - 5000) mg/l C"},{"name":"范围","range":"(10 - 50000) mg/kg"}],"search_zh":"高温燃烧红外检测法 范围 范围 PN-EN 1484:1999 | PN-EN 12457-4:2006","technique_zh":"高温燃烧红外检测法"},{"_id":"6a8369ecaf14b9c0e7b1ddcf","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Odpady kod: 02 01 03, 02 03 01, 02 03 80, 10 01 01, 17 01 07, 17 01 80, 17 01 81, 17 01 82, 17 03 02, 17 03 80, 17 06 04, 17 09 04, 19 01 12, 19 06 04, 19 08 02, 19 09 01, 19 09 02, 19 12 09, 20 03 06, Odpady DAB-11: - Odpady z przetwarzania odpadów (VI) - Osady ściekowe (IX) - Tworzywa sztuczne (XXV) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII)","methodology":"Substancje rozpuszczone (TDS) 1,2","parameters":[{"name":"Zakres","range":"(3,00 - 100000) mg/l"},{"name":"Zakres","range":"(30,0 - 100000) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Substancje rozpuszczone (TDS) 1,2\nZakres:\nZakres (3,00 - 100000) mg/l\nZakres (30,0 - 100000) mg/kg\nMetoda wagowa","reference":"APHA Standard Metod 2540 C:1999 | PN-EN 12457-4:2006","norm_bases":["APHA Standard Metod 2540 C:1999","PN-EN 12457-4:2006"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: 1 - Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 roku w sprawie w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. z 2015, poz. 1277) 2 - Rozporządzeniem Ministra Środowiska z dnia 28 grudnia 2011 roku w sprawie w sprawie podziemnych składowisk odpadów (Dz. U. z 2011 nr 298, poz. 1771) 3 - Rozporządzenie Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (DZ. U. z 2017, poz. 2490) 4 - Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2023. poz. 23) 5 - Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 roku w sprawie procesu R10 (Dz. U. z 2015, poz. 132) | Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. | Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11","flexible":false,"search_text":"Odpady kod: 02 01 03, 02 03 01, 02 03 80, 10 01 01, 17 01 07, 17 01 80, 17 01 81, 17 01 82, 17 03 02, 17 03 80, 17 06 04, 17 09 04, 19 01 12, 19 06 04, 19 08 02, 19 09 01, 19 09 02, 19 12 09, 20 03 06, Odpady DAB-11: - Odpady z przetwarzania odpadów (VI) - Osady ściekowe (IX) - Tworzywa sztuczne (XXV) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII) Substancje rozpuszczone (TDS) 1,2\nZakres:\nZakres (3,00 - 100000) mg/l\nZakres (30,0 - 100000) mg/kg\nMetoda wagowa APHA Standard Metod 2540 C:1999 | PN-EN 12457-4:2006 Odpady kod: 02 01 03, 02 03 01, 02 03 80, 10 01 01, 17 01 07, 17 01 80, 17 01 81, 17 01 82, 17 03 02, 17 03 80, 17 06 04, 17 09 04, 19 01 12, 19 06 04, 19 08 02, 19 09 01, 19 09 02, 19 12 09, 20 03 06, Odpady DAB-11: - Odpady z przetwarzania odpadow (VI) - Osady sciekowe (IX) - Tworzywa sztuczne (XXV) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII) Substancje rozpuszczone (TDS) 1,2\nZakres:\nZakres (3,00 - 100000) mg/l\nZakres (30,0 - 100000) mg/kg\nMetoda wagowa APHA Standard Metod 2540 C:1999 | PN-EN 12457-4:2006","categories":["water","environment","materials"],"row_index":429,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissolved solids (TDS) 1,2","parameters_en":[{"name":"Range","range":"(3,00 - 100000) mg/l"},{"name":"Range","range":"(30,0 - 100000) mg/kg"}],"search_en":"Dissolved solids (TDS) 1,2 Gravimetric method Range Range APHA Standard Metod 2540 C:1999 | PN-EN 12457-4:2006","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(3,00 - 100000) mg/l"},{"name":"范围","range":"(30,0 - 100000) mg/kg"}],"search_zh":"重量法 范围 范围 APHA Standard Metod 2540 C:1999 | PN-EN 12457-4:2006","technique_zh":"重量法"},{"_id":"6a8369ecaf14b9c0e7b1ddd0","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Odpady kod: 02 01 03, 02 03 01, 02 03 80, 10 01 01, 17 01 07, 17 01 80, 17 01 81, 17 01 82, 17 03 02, 17 03 80, 17 06 04, 17 09 04, 19 01 12, 19 06 04, 19 08 02, 19 09 01, 19 09 02, 19 12 09, 20 03 06, Odpady DAB-11: - Odpady z przetwarzania odpadów (VI) - Osady ściekowe (IX) - Tworzywa sztuczne (XXV) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII)","methodology":"Całkowite substancje 1,2 rozpuszczone (TDS)","parameters":[{"name":"Zakres","range":"(3,00 - 100000) mg/l"},{"name":"Zakres","range":"(30 - 100000) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Całkowite substancje 1,2 rozpuszczone (TDS)\nZakres:\nZakres (3,00 - 100000) mg/l\nZakres (30 - 100000) mg/kg\nMetoda wagowa","reference":"PN-EN 15216:2010 | PN-EN 12457-4:2006","norm_bases":["PN-EN 15216:2010","PN-EN 12457-4:2006"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: 1 - Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 roku w sprawie w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. z 2015, poz. 1277) 2 - Rozporządzeniem Ministra Środowiska z dnia 28 grudnia 2011 roku w sprawie w sprawie podziemnych składowisk odpadów (Dz. U. z 2011 nr 298, poz. 1771) 3 - Rozporządzenie Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (DZ. U. z 2017, poz. 2490) 4 - Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2023. poz. 23) 5 - Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 roku w sprawie procesu R10 (Dz. U. z 2015, poz. 132) | Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. | Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11","flexible":false,"search_text":"Odpady kod: 02 01 03, 02 03 01, 02 03 80, 10 01 01, 17 01 07, 17 01 80, 17 01 81, 17 01 82, 17 03 02, 17 03 80, 17 06 04, 17 09 04, 19 01 12, 19 06 04, 19 08 02, 19 09 01, 19 09 02, 19 12 09, 20 03 06, Odpady DAB-11: - Odpady z przetwarzania odpadów (VI) - Osady ściekowe (IX) - Tworzywa sztuczne (XXV) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII) Całkowite substancje 1,2 rozpuszczone (TDS)\nZakres:\nZakres (3,00 - 100000) mg/l\nZakres (30 - 100000) mg/kg\nMetoda wagowa PN-EN 15216:2010 | PN-EN 12457-4:2006 Odpady kod: 02 01 03, 02 03 01, 02 03 80, 10 01 01, 17 01 07, 17 01 80, 17 01 81, 17 01 82, 17 03 02, 17 03 80, 17 06 04, 17 09 04, 19 01 12, 19 06 04, 19 08 02, 19 09 01, 19 09 02, 19 12 09, 20 03 06, Odpady DAB-11: - Odpady z przetwarzania odpadow (VI) - Osady sciekowe (IX) - Tworzywa sztuczne (XXV) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII) Calkowite substancje 1,2 rozpuszczone (TDS)\nZakres:\nZakres (3,00 - 100000) mg/l\nZakres (30 - 100000) mg/kg\nMetoda wagowa PN-EN 15216:2010 | PN-EN 12457-4:2006","categories":["water","environment","materials"],"row_index":430,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total dissolved solids 1,2 (TDS)","parameters_en":[{"name":"Range","range":"(3,00 - 100000) mg/l"},{"name":"Range","range":"(30 - 100000) mg/kg"}],"search_en":"Total dissolved solids 1,2 (TDS) Gravimetric method Range Range PN-EN 15216:2010 | PN-EN 12457-4:2006","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(3,00 - 100000) mg/l"},{"name":"范围","range":"(30 - 100000) mg/kg"}],"search_zh":"重量法 范围 范围 PN-EN 15216:2010 | PN-EN 12457-4:2006","technique_zh":"重量法"},{"_id":"6a8369ecaf14b9c0e7b1ddd1","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Odpady kod: 02 01 03, 02 03 01, 02 03 80, 10 01 01, 17 01 07, 17 01 80, 17 01 81, 17 01 82, 17 03 02, 17 03 80, 17 06 04, 17 09 04, 19 01 12, 19 06 04, 19 08 02, 19 09 01, 19 09 02, 19 12 09, 20 03 06, Odpady DAB-11: - Odpady z przetwarzania odpadów (VI) - Osady ściekowe (IX) - Tworzywa sztuczne (XXV) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII)","methodology":"Stężenie i zawartość rtęci 1,2","parameters":[{"name":"Zakres","range":"(0,0005 - 0,30) mg/l"},{"name":"Zakres","range":"(0,005 - 3,0) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","techniques":["Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji"],"computed":[],"activity":"Stężenie i zawartość rtęci 1,2\nZakres:\nZakres (0,0005 - 0,30) mg/l\nZakres (0,005 - 3,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","reference":"PN-EN 12457-4:2006 | PB-DAN-24 wersja 01 z dnia 16.02.2021 r.","norm_bases":["PN-EN 12457-4:2006","PB-DAN-24 wersja 01 z dnia 16.02.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: 1 - Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 roku w sprawie w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. z 2015, poz. 1277) 2 - Rozporządzeniem Ministra Środowiska z dnia 28 grudnia 2011 roku w sprawie w sprawie podziemnych składowisk odpadów (Dz. U. z 2011 nr 298, poz. 1771) 3 - Rozporządzenie Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (DZ. U. z 2017, poz. 2490) 4 - Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2023. poz. 23) 5 - Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 roku w sprawie procesu R10 (Dz. U. z 2015, poz. 132) | Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. | Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11","flexible":false,"search_text":"Odpady kod: 02 01 03, 02 03 01, 02 03 80, 10 01 01, 17 01 07, 17 01 80, 17 01 81, 17 01 82, 17 03 02, 17 03 80, 17 06 04, 17 09 04, 19 01 12, 19 06 04, 19 08 02, 19 09 01, 19 09 02, 19 12 09, 20 03 06, Odpady DAB-11: - Odpady z przetwarzania odpadów (VI) - Osady ściekowe (IX) - Tworzywa sztuczne (XXV) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII) Stężenie i zawartość rtęci 1,2\nZakres:\nZakres (0,0005 - 0,30) mg/l\nZakres (0,005 - 3,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji PN-EN 12457-4:2006 | PB-DAN-24 wersja 01 z dnia 16.02.2021 r. Odpady kod: 02 01 03, 02 03 01, 02 03 80, 10 01 01, 17 01 07, 17 01 80, 17 01 81, 17 01 82, 17 03 02, 17 03 80, 17 06 04, 17 09 04, 19 01 12, 19 06 04, 19 08 02, 19 09 01, 19 09 02, 19 12 09, 20 03 06, Odpady DAB-11: - Odpady z przetwarzania odpadow (VI) - Osady sciekowe (IX) - Tworzywa sztuczne (XXV) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII) Stezenie i zawartosc rteci 1,2\nZakres:\nZakres (0,0005 - 0,30) mg/l\nZakres (0,005 - 3,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z technika amalgamacji PN-EN 12457-4:2006 | PB-DAN-24 wersja 01 z dnia 16.02.2021 r.","categories":["water","environment","materials"],"row_index":431,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury concentration and content 1,2","parameters_en":[{"name":"Range","range":"(0,0005 - 0,30) mg/l"},{"name":"Range","range":"(0,005 - 3,0) mg/kg"}],"search_en":"Mercury concentration and content 1,2 Atomic absorption spectrometry with amalgamation technique Range Range PN-EN 12457-4:2006 | PB-DAN-24 wersja 01 z dnia 16.02.2021 r.","technique_en":"Atomic absorption spectrometry with amalgamation technique","parameters_zh":[{"name":"范围","range":"(0,0005 - 0,30) mg/l"},{"name":"范围","range":"(0,005 - 3,0) mg/kg"}],"search_zh":"原子吸收光谱法（汞齐化技术） 范围 范围 PN-EN 12457-4:2006 | PB-DAN-24 wersja 01 z dnia 16.02.2021 r.","technique_zh":"原子吸收光谱法（汞齐化技术）"},{"_id":"6a8369ecaf14b9c0e7b1ddd2","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Odpady kod: 02 01 03, 02 03 01, 02 03 80, 10 01 01, 17 01 07, 17 01 80, 17 01 81, 17 01 82, 17 03 02, 17 03 80, 17 06 04, 17 09 04, 19 01 12, 19 06 04, 19 08 02, 19 09 01, 19 09 02, 19 12 09, 20 03 06, Odpady DAB-11: - Odpady z przetwarzania odpadów (VI) - Osady ściekowe (IX) - Tworzywa sztuczne (XXV) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII)","methodology":"Stężenie chlorków 1,2","parameters":[{"name":"Zakres","range":"(2,50 - 6000) mg/l"},{"name":"Zakres","range":"(25,0 - 60000) mg/kg"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie chlorków 1,2\nZakres:\nZakres (2,50 - 6000) mg/l\nZakres (25,0 - 60000) mg/kg\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 15682:2004 | PN-EN 12457-4:2006","norm_bases":["PN-EN ISO 15682:2004","PN-EN 12457-4:2006"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: 1 - Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 roku w sprawie w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. z 2015, poz. 1277) 2 - Rozporządzeniem Ministra Środowiska z dnia 28 grudnia 2011 roku w sprawie w sprawie podziemnych składowisk odpadów (Dz. U. z 2011 nr 298, poz. 1771) 3 - Rozporządzenie Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (DZ. U. z 2017, poz. 2490) 4 - Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2023. poz. 23) 5 - Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 roku w sprawie procesu R10 (Dz. U. z 2015, poz. 132) | Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. | Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11","flexible":false,"search_text":"Odpady kod: 02 01 03, 02 03 01, 02 03 80, 10 01 01, 17 01 07, 17 01 80, 17 01 81, 17 01 82, 17 03 02, 17 03 80, 17 06 04, 17 09 04, 19 01 12, 19 06 04, 19 08 02, 19 09 01, 19 09 02, 19 12 09, 20 03 06, Odpady DAB-11: - Odpady z przetwarzania odpadów (VI) - Osady ściekowe (IX) - Tworzywa sztuczne (XXV) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII) Stężenie chlorków 1,2\nZakres:\nZakres (2,50 - 6000) mg/l\nZakres (25,0 - 60000) mg/kg\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 15682:2004 | PN-EN 12457-4:2006 Odpady kod: 02 01 03, 02 03 01, 02 03 80, 10 01 01, 17 01 07, 17 01 80, 17 01 81, 17 01 82, 17 03 02, 17 03 80, 17 06 04, 17 09 04, 19 01 12, 19 06 04, 19 08 02, 19 09 01, 19 09 02, 19 12 09, 20 03 06, Odpady DAB-11: - Odpady z przetwarzania odpadow (VI) - Osady sciekowe (IX) - Tworzywa sztuczne (XXV) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII) Stezenie chlorkow 1,2\nZakres:\nZakres (2,50 - 6000) mg/l\nZakres (25,0 - 60000) mg/kg\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 15682:2004 | PN-EN 12457-4:2006","categories":["water","environment","materials"],"row_index":432,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride concentration 1,2","parameters_en":[{"name":"Range","range":"(2,50 - 6000) mg/l"},{"name":"Range","range":"(25,0 - 60000) mg/kg"}],"search_en":"Chloride concentration 1,2 Continuous flow analysis (CFA) with spectrophotometric detection Range Range PN-EN ISO 15682:2004 | PN-EN 12457-4:2006","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","parameters_zh":[{"name":"范围","range":"(2,50 - 6000) mg/l"},{"name":"范围","range":"(25,0 - 60000) mg/kg"}],"search_zh":"连续流动分析（CFA）分光光度检测法 范围 范围 PN-EN ISO 15682:2004 | PN-EN 12457-4:2006","technique_zh":"连续流动分析（CFA）分光光度检测法"},{"_id":"6a8369ecaf14b9c0e7b1ddd3","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Odpady kod: 02 01 03, 02 03 01, 02 03 80, 10 01 01, 17 01 07, 17 01 80, 17 01 81, 17 01 82, 17 03 02, 17 03 80, 17 06 04, 17 09 04, 19 01 12, 19 06 04, 19 08 02, 19 09 01, 19 09 02, 19 12 09, 20 03 06, Odpady DAB-11: - Odpady z przetwarzania odpadów (VI) - Osady ściekowe (IX) - Tworzywa sztuczne (XXV) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII)","methodology":"Stężenie fluorków 1,2","parameters":[{"name":"Zakres","range":"(0,50 - 500) mg/l"},{"name":"Zakres","range":"(5,00 - 5000) mg/kg"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie fluorków 1,2\nZakres:\nZakres (0,50 - 500) mg/l\nZakres (5,00 - 5000) mg/kg\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PB-DAN-22 wersja 01 z dnia 16.02.2021 r. | PN-EN 12457-4:2006","norm_bases":["PB-DAN-22 wersja 01 z dnia 16.02.2021 r.","PN-EN 12457-4:2006"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: 1 - Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 roku w sprawie w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. z 2015, poz. 1277) 2 - Rozporządzeniem Ministra Środowiska z dnia 28 grudnia 2011 roku w sprawie w sprawie podziemnych składowisk odpadów (Dz. U. z 2011 nr 298, poz. 1771) 3 - Rozporządzenie Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (DZ. U. z 2017, poz. 2490) 4 - Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2023. poz. 23) 5 - Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 roku w sprawie procesu R10 (Dz. U. z 2015, poz. 132) | Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. | Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11","flexible":false,"search_text":"Odpady kod: 02 01 03, 02 03 01, 02 03 80, 10 01 01, 17 01 07, 17 01 80, 17 01 81, 17 01 82, 17 03 02, 17 03 80, 17 06 04, 17 09 04, 19 01 12, 19 06 04, 19 08 02, 19 09 01, 19 09 02, 19 12 09, 20 03 06, Odpady DAB-11: - Odpady z przetwarzania odpadów (VI) - Osady ściekowe (IX) - Tworzywa sztuczne (XXV) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII) Stężenie fluorków 1,2\nZakres:\nZakres (0,50 - 500) mg/l\nZakres (5,00 - 5000) mg/kg\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PB-DAN-22 wersja 01 z dnia 16.02.2021 r. | PN-EN 12457-4:2006 Odpady kod: 02 01 03, 02 03 01, 02 03 80, 10 01 01, 17 01 07, 17 01 80, 17 01 81, 17 01 82, 17 03 02, 17 03 80, 17 06 04, 17 09 04, 19 01 12, 19 06 04, 19 08 02, 19 09 01, 19 09 02, 19 12 09, 20 03 06, Odpady DAB-11: - Odpady z przetwarzania odpadow (VI) - Osady sciekowe (IX) - Tworzywa sztuczne (XXV) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII) Stezenie fluorkow 1,2\nZakres:\nZakres (0,50 - 500) mg/l\nZakres (5,00 - 5000) mg/kg\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PB-DAN-22 wersja 01 z dnia 16.02.2021 r. | PN-EN 12457-4:2006","categories":["water","environment","materials"],"row_index":433,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fluoride concentration 1,2","parameters_en":[{"name":"Range","range":"(0,50 - 500) mg/l"},{"name":"Range","range":"(5,00 - 5000) mg/kg"}],"search_en":"Fluoride concentration 1,2 Continuous flow analysis (CFA) with spectrophotometric detection Range Range PB-DAN-22 wersja 01 z dnia 16.02.2021 r. | PN-EN 12457-4:2006","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","parameters_zh":[{"name":"范围","range":"(0,50 - 500) mg/l"},{"name":"范围","range":"(5,00 - 5000) mg/kg"}],"search_zh":"连续流动分析（CFA）分光光度检测法 范围 范围 PB-DAN-22 wersja 01 z dnia 16.02.2021 r. | PN-EN 12457-4:2006","technique_zh":"连续流动分析（CFA）分光光度检测法"},{"_id":"6a8369ecaf14b9c0e7b1ddd4","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Odpady kod: 02 01 03, 02 03 01, 02 03 80, 10 01 01, 17 01 07, 17 01 80, 17 01 81, 17 01 82, 17 03 02, 17 03 80, 17 06 04, 17 09 04, 19 01 12, 19 06 04, 19 08 02, 19 09 01, 19 09 02, 19 12 09, 20 03 06, Odpady DAB-11: - Odpady z przetwarzania odpadów (VI) - Osady ściekowe (IX) - Tworzywa sztuczne (XXV) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII)","methodology":"Stężenie siarczanów 1,2","parameters":[{"name":"Zakres","range":"(5,00 - 10000) mg/l"},{"name":"Zakres","range":"(50,0 - 100000) mg/kg"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie siarczanów 1,2\nZakres:\nZakres (5,00 - 10000) mg/l\nZakres (50,0 - 100000) mg/kg\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"ISO 22743:2006 | PN-EN 12457-4:2006","norm_bases":["ISO 22743:2006","PN-EN 12457-4:2006"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: 1 - Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 roku w sprawie w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. z 2015, poz. 1277) 2 - Rozporządzeniem Ministra Środowiska z dnia 28 grudnia 2011 roku w sprawie w sprawie podziemnych składowisk odpadów (Dz. U. z 2011 nr 298, poz. 1771) 3 - Rozporządzenie Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (DZ. U. z 2017, poz. 2490) 4 - Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2023. poz. 23) 5 - Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 roku w sprawie procesu R10 (Dz. U. z 2015, poz. 132) | Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. | Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11","flexible":false,"search_text":"Odpady kod: 02 01 03, 02 03 01, 02 03 80, 10 01 01, 17 01 07, 17 01 80, 17 01 81, 17 01 82, 17 03 02, 17 03 80, 17 06 04, 17 09 04, 19 01 12, 19 06 04, 19 08 02, 19 09 01, 19 09 02, 19 12 09, 20 03 06, Odpady DAB-11: - Odpady z przetwarzania odpadów (VI) - Osady ściekowe (IX) - Tworzywa sztuczne (XXV) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII) Stężenie siarczanów 1,2\nZakres:\nZakres (5,00 - 10000) mg/l\nZakres (50,0 - 100000) mg/kg\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną ISO 22743:2006 | PN-EN 12457-4:2006 Odpady kod: 02 01 03, 02 03 01, 02 03 80, 10 01 01, 17 01 07, 17 01 80, 17 01 81, 17 01 82, 17 03 02, 17 03 80, 17 06 04, 17 09 04, 19 01 12, 19 06 04, 19 08 02, 19 09 01, 19 09 02, 19 12 09, 20 03 06, Odpady DAB-11: - Odpady z przetwarzania odpadow (VI) - Osady sciekowe (IX) - Tworzywa sztuczne (XXV) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII) Stezenie siarczanow 1,2\nZakres:\nZakres (5,00 - 10000) mg/l\nZakres (50,0 - 100000) mg/kg\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna ISO 22743:2006 | PN-EN 12457-4:2006","categories":["water","environment","materials"],"row_index":434,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulphate concentration 1,2","parameters_en":[{"name":"Range","range":"(5,00 - 10000) mg/l"},{"name":"Range","range":"(50,0 - 100000) mg/kg"}],"search_en":"Sulphate concentration 1,2 Continuous flow analysis (CFA) with spectrophotometric detection Range Range ISO 22743:2006 | PN-EN 12457-4:2006","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","parameters_zh":[{"name":"范围","range":"(5,00 - 10000) mg/l"},{"name":"范围","range":"(50,0 - 100000) mg/kg"}],"search_zh":"连续流动分析（CFA）分光光度检测法 范围 范围 ISO 22743:2006 | PN-EN 12457-4:2006","technique_zh":"连续流动分析（CFA）分光光度检测法"},{"_id":"6a8369ecaf14b9c0e7b1ddd5","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Odpady kod: 02 01 03, 02 03 01, 02 03 80, 10 01 01, 17 01 07, 17 01 81, 17 03 02, 17 03 80, 17 06 04, 17 09 04, 19 01 12, 19 06 04, 19 08 02, 19 09 01, 19 09 02, 19 12 09, 20 03 06, 17 01 80, 17 01 82, Odpady DAB-11: - Odpady z przetwarzania odpadów (VI)","methodology":"Zawartość ogólnego węgla 1,2,3 organicznego (TOC)","parameters":[{"name":"Zakres","range":"(1 - 500) g/kg"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość ogólnego węgla 1,2,3 organicznego (TOC)\nZakres (1 - 500) g/kg\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN 15936:2022-07","norm_bases":["PN-EN 15936:2022-07"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":"Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. | Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.","flexible":false,"search_text":"Odpady kod: 02 01 03, 02 03 01, 02 03 80, 10 01 01, 17 01 07, 17 01 81, 17 03 02, 17 03 80, 17 06 04, 17 09 04, 19 01 12, 19 06 04, 19 08 02, 19 09 01, 19 09 02, 19 12 09, 20 03 06, 17 01 80, 17 01 82, Odpady DAB-11: - Odpady z przetwarzania odpadów (VI) Zawartość ogólnego węgla 1,2,3 organicznego (TOC)\nZakres (1 - 500) g/kg\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN 15936:2022-07 Odpady kod: 02 01 03, 02 03 01, 02 03 80, 10 01 01, 17 01 07, 17 01 81, 17 03 02, 17 03 80, 17 06 04, 17 09 04, 19 01 12, 19 06 04, 19 08 02, 19 09 01, 19 09 02, 19 12 09, 20 03 06, 17 01 80, 17 01 82, Odpady DAB-11: - Odpady z przetwarzania odpadow (VI) Zawartosc ogolnego wegla 1,2,3 organicznego (TOC)\nZakres (1 - 500) g/kg\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN 15936:2022-07","categories":["environment"],"row_index":435,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total organic carbon content 1,2,3 (TOC)","parameters_en":[{"name":"Range","range":"(1 - 500) g/kg"}],"search_en":"Total organic carbon content 1,2,3 (TOC) High-temperature combustion with IR detection Range PN-EN 15936:2022-07","technique_en":"High-temperature combustion with IR detection","parameters_zh":[{"name":"范围","range":"(1 - 500) g/kg"}],"search_zh":"高温燃烧红外检测法 范围 PN-EN 15936:2022-07","technique_zh":"高温燃烧红外检测法"},{"_id":"6a8369ecaf14b9c0e7b1ddd6","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Odpady kod: 02 01 03, 02 03 01, 02 03 80, 10 01 01, 17 01 07, 17 01 81, 17 03 02, 17 03 80, 17 06 04, 17 09 04, 19 01 12, 19 06 04, 19 08 02, 19 09 01, 19 09 02, 19 12 09, 20 03 06, 17 01 80, 17 01 82, Odpady DAB-11: - Odpady z przetwarzania odpadów (VI)","methodology":"Straty przy prażeniu suchej masy(LOI) / Pozostałość po prażeniu 1,2,3,4,5","parameters":[{"name":"Zakres","range":"(0,1 - 99,5) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Straty przy prażeniu suchej masy(LOI) / Pozostałość po prażeniu 1,2,3,4,5\nZakres (0,1 - 99,5) %\nMetoda wagowa","reference":"PN-EN 15935:2022-01","norm_bases":["PN-EN 15935:2022-01"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":"Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. | Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.","flexible":false,"search_text":"Odpady kod: 02 01 03, 02 03 01, 02 03 80, 10 01 01, 17 01 07, 17 01 81, 17 03 02, 17 03 80, 17 06 04, 17 09 04, 19 01 12, 19 06 04, 19 08 02, 19 09 01, 19 09 02, 19 12 09, 20 03 06, 17 01 80, 17 01 82, Odpady DAB-11: - Odpady z przetwarzania odpadów (VI) Straty przy prażeniu suchej masy(LOI) / Pozostałość po prażeniu 1,2,3,4,5\nZakres (0,1 - 99,5) %\nMetoda wagowa PN-EN 15935:2022-01 Odpady kod: 02 01 03, 02 03 01, 02 03 80, 10 01 01, 17 01 07, 17 01 81, 17 03 02, 17 03 80, 17 06 04, 17 09 04, 19 01 12, 19 06 04, 19 08 02, 19 09 01, 19 09 02, 19 12 09, 20 03 06, 17 01 80, 17 01 82, Odpady DAB-11: - Odpady z przetwarzania odpadow (VI) Straty przy prazeniu suchej masy(LOI) / Pozostalosc po prazeniu 1,2,3,4,5\nZakres (0,1 - 99,5) %\nMetoda wagowa PN-EN 15935:2022-01","categories":["environment"],"row_index":436,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,1 - 99,5) %"}],"search_en":"Gravimetric method Range PN-EN 15935:2022-01","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(0,1 - 99,5) %"}],"search_zh":"重量法 范围 PN-EN 15935:2022-01","technique_zh":"重量法"},{"_id":"6a8369ecaf14b9c0e7b1ddd7","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Odpady kod: 02 01 03, 02 03 01, 02 03 80, 10 01 01, 17 01 07, 17 01 81, 17 03 02, 17 03 80, 17 06 04, 17 09 04, 19 01 12, 19 06 04, 19 08 02, 19 09 01, 19 09 02, 19 12 09, 20 03 06, 17 01 80, 17 01 82, Odpady DAB-11: - Odpady z przetwarzania odpadów (VI)","methodology":"Zawartość substancji mineralnych (z obliczeń) 1,2,3,4,5","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość substancji mineralnych (z obliczeń) 1,2,3,4,5","reference":"PN-EN 15935:2022-01","norm_bases":["PN-EN 15935:2022-01"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":"Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. | Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.","flexible":false,"search_text":"Odpady kod: 02 01 03, 02 03 01, 02 03 80, 10 01 01, 17 01 07, 17 01 81, 17 03 02, 17 03 80, 17 06 04, 17 09 04, 19 01 12, 19 06 04, 19 08 02, 19 09 01, 19 09 02, 19 12 09, 20 03 06, 17 01 80, 17 01 82, Odpady DAB-11: - Odpady z przetwarzania odpadów (VI) Zawartość substancji mineralnych (z obliczeń) 1,2,3,4,5 PN-EN 15935:2022-01 Odpady kod: 02 01 03, 02 03 01, 02 03 80, 10 01 01, 17 01 07, 17 01 81, 17 03 02, 17 03 80, 17 06 04, 17 09 04, 19 01 12, 19 06 04, 19 08 02, 19 09 01, 19 09 02, 19 12 09, 20 03 06, 17 01 80, 17 01 82, Odpady DAB-11: - Odpady z przetwarzania odpadow (VI) Zawartosc substancji mineralnych (z obliczen) 1,2,3,4,5 PN-EN 15935:2022-01","categories":["environment"],"row_index":437,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of mineral substances (calculated) 1,2,3,4,5","search_en":"Content of mineral substances (calculated) 1,2,3,4,5 PN-EN 15935:2022-01"},{"_id":"6a8369ecaf14b9c0e7b1ddd8","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"- Osady ściekowe (IX)","methodology":"Sucha masa /zawartość wody 1,3,4,5","parameters":[{"name":"Zakres","range":"(0,10 - 99,5) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha masa /zawartość wody 1,3,4,5\nZakres (0,10 - 99,5) %\nMetoda wagowa","reference":"PN-EN 15934:2013-02 z wyłączeniem punktu 7 Metoda B","norm_bases":["PN-EN 15934:2013-02 z wyłączeniem punktu 7 Metoda B"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":"Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. | Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.","flexible":false,"search_text":"- Osady ściekowe (IX) Sucha masa /zawartość wody 1,3,4,5\nZakres (0,10 - 99,5) %\nMetoda wagowa PN-EN 15934:2013-02 z wyłączeniem punktu 7 Metoda B - Osady sciekowe (IX) Sucha masa /zawartosc wody 1,3,4,5\nZakres (0,10 - 99,5) %\nMetoda wagowa PN-EN 15934:2013-02 z wylaczeniem punktu 7 Metoda B","categories":["water"],"row_index":438,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,10 - 99,5) %"}],"search_en":"- Sewage sludge (IX) Gravimetric method Range PN-EN 15934:2013-02 z wyłączeniem punktu 7 Metoda B","technique_en":"Gravimetric method","test_object_en":"- Sewage sludge (IX)","parameters_zh":[{"name":"范围","range":"(0,10 - 99,5) %"}],"search_zh":"重量法 范围 PN-EN 15934:2013-02 z wyłączeniem punktu 7 Metoda B","technique_zh":"重量法"},{"_id":"6a8369ecaf14b9c0e7b1ddd9","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Odpady kod: 19 06 04, 19 08 02, 19 09 01, 19 09 02, 19 12 09, 20 02 03, 20 03 06, Odpady DAB-11: - Odpady z przetwarzania odpadów (VI)","methodology":"Aktywność oddechowa AT4 3","parameters":[{"name":"Zakres","range":"(1,00 - 30,0) mg/g O2"}],"technique":"Metoda manometryczna","techniques":["Metoda manometryczna"],"computed":[],"activity":"Aktywność oddechowa AT4 3\nZakres (1,00 - 30,0) mg/g O2\nMetoda manometryczna","reference":"PB-DAN-19 wersja 01 z dnia 16.02.2021 r.","norm_bases":["PB-DAN-19 wersja 01 z dnia 16.02.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":"Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. | Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.","flexible":false,"search_text":"Odpady kod: 19 06 04, 19 08 02, 19 09 01, 19 09 02, 19 12 09, 20 02 03, 20 03 06, Odpady DAB-11: - Odpady z przetwarzania odpadów (VI) Aktywność oddechowa AT4 3\nZakres (1,00 - 30,0) mg/g O2\nMetoda manometryczna PB-DAN-19 wersja 01 z dnia 16.02.2021 r. Odpady kod: 19 06 04, 19 08 02, 19 09 01, 19 09 02, 19 12 09, 20 02 03, 20 03 06, Odpady DAB-11: - Odpady z przetwarzania odpadow (VI) Aktywnosc oddechowa AT4 3\nZakres (1,00 - 30,0) mg/g O2\nMetoda manometryczna PB-DAN-19 wersja 01 z dnia 16.02.2021 r.","categories":["environment","metrology"],"row_index":439,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Respiration activity AT4 3","parameters_en":[{"name":"Range","range":"(1,00 - 30,0) mg/g O2"}],"search_en":"Respiration activity AT4 3 Manometric method Range PB-DAN-19 wersja 01 z dnia 16.02.2021 r.","technique_en":"Manometric method","parameters_zh":[{"name":"范围","range":"(1,00 - 30,0) mg/g O2"}],"search_zh":"压力计法 范围 PB-DAN-19 wersja 01 z dnia 16.02.2021 r.","technique_zh":"压力计法"},{"_id":"6a8369ecaf14b9c0e7b1ddda","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Odpady DAB-11: - Osady ściekowe (IX)","methodology":"Zawartość rtęci 4,5","parameters":[{"name":"Zakres","range":"(0,005 - 10,00) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","techniques":["Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji"],"computed":[],"activity":"Zawartość rtęci 4,5\nZakres (0,005 - 10,00) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","reference":"PB-DAN-25 wersja 01 z dnia 16.02.2021 r.","norm_bases":["PB-DAN-25 wersja 01 z dnia 16.02.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":"Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. | Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.","flexible":false,"search_text":"Odpady DAB-11: - Osady ściekowe (IX) Zawartość rtęci 4,5\nZakres (0,005 - 10,00) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji PB-DAN-25 wersja 01 z dnia 16.02.2021 r. Odpady DAB-11: - Osady sciekowe (IX) Zawartosc rteci 4,5\nZakres (0,005 - 10,00) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z technika amalgamacji PB-DAN-25 wersja 01 z dnia 16.02.2021 r.","categories":["water","environment"],"row_index":440,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury content 4,5","parameters_en":[{"name":"Range","range":"(0,005 - 10,00) mg/kg"}],"search_en":"Mercury content 4,5 Atomic absorption spectrometry with amalgamation technique Range PB-DAN-25 wersja 01 z dnia 16.02.2021 r.","technique_en":"Atomic absorption spectrometry with amalgamation technique","parameters_zh":[{"name":"范围","range":"(0,005 - 10,00) mg/kg"}],"search_zh":"原子吸收光谱法（汞齐化技术） 范围 PB-DAN-25 wersja 01 z dnia 16.02.2021 r.","technique_zh":"原子吸收光谱法（汞齐化技术）"},{"_id":"6a8369ecaf14b9c0e7b1dddb","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Odpady DAB-11: - Osady ściekowe (IX)","methodology":"Zawartość azotu amonowego 4,5","parameters":[{"name":"Zakres","range":"(0,10 - 10) %"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Zawartość azotu amonowego 4,5\nZakres (0,10 - 10) %\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN 14671:2007 | PN-EN ISO 11732:2007","norm_bases":["PN-EN 14671:2007","PN-EN ISO 11732:2007"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":"Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. | Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.","flexible":false,"search_text":"Odpady DAB-11: - Osady ściekowe (IX) Zawartość azotu amonowego 4,5\nZakres (0,10 - 10) %\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN 14671:2007 | PN-EN ISO 11732:2007 Odpady DAB-11: - Osady sciekowe (IX) Zawartosc azotu amonowego 4,5\nZakres (0,10 - 10) %\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN 14671:2007 | PN-EN ISO 11732:2007","categories":["water","environment"],"row_index":441,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen content 4,5","parameters_en":[{"name":"Range","range":"(0,10 - 10) %"}],"search_en":"Ammonium nitrogen content 4,5 Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN 14671:2007 | PN-EN ISO 11732:2007","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","parameters_zh":[{"name":"范围","range":"(0,10 - 10) %"}],"search_zh":"连续流动分析（CFA）分光光度检测法 范围 PN-EN 14671:2007 | PN-EN ISO 11732:2007","technique_zh":"连续流动分析（CFA）分光光度检测法"},{"_id":"6a8369ecaf14b9c0e7b1dddc","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Odpady DAB-11: - Osady ściekowe (IX)","methodology":"Zawartość azotu ogólnego 4,5","parameters":[{"name":"Zakres","range":"(1,00 - 20,0) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją TC","techniques":["Metoda wysokotemperaturowego spalania z detekcją TC"],"computed":[],"activity":"Zawartość azotu ogólnego 4,5\nZakres (1,00 - 20,0) %\nMetoda wysokotemperaturowego spalania z detekcją TC","reference":"PN-EN 16168:2012","norm_bases":["PN-EN 16168:2012"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":"Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. | Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.","flexible":false,"search_text":"Odpady DAB-11: - Osady ściekowe (IX) Zawartość azotu ogólnego 4,5\nZakres (1,00 - 20,0) %\nMetoda wysokotemperaturowego spalania z detekcją TC PN-EN 16168:2012 Odpady DAB-11: - Osady sciekowe (IX) Zawartosc azotu ogolnego 4,5\nZakres (1,00 - 20,0) %\nMetoda wysokotemperaturowego spalania z detekcja TC PN-EN 16168:2012","categories":["water","environment"],"row_index":442,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total nitrogen content 4,5","parameters_en":[{"name":"Range","range":"(1,00 - 20,0) %"}],"search_en":"Total nitrogen content 4,5 High-temperature combustion with TC detection Range PN-EN 16168:2012","technique_en":"High-temperature combustion with TC detection","parameters_zh":[{"name":"范围","range":"(1,00 - 20,0) %"}],"search_zh":"高温燃烧总碳检测法 范围 PN-EN 16168:2012","technique_zh":"高温燃烧总碳检测法"},{"_id":"6a8369ecaf14b9c0e7b1dddd","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Odpady DAB-11: - Osady ściekowe (IX)","methodology":"pH - w H2O 4,5","parameters":[{"name":"Zakres","range":"2,0 - 13,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH - w H2O 4,5\nZakres 2,0 - 13,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":"Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. | Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.","flexible":false,"search_text":"Odpady DAB-11: - Osady ściekowe (IX) pH - w H2O 4,5\nZakres 2,0 - 13,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 Odpady DAB-11: - Osady sciekowe (IX) pH - w H2O 4,5\nZakres 2,0 - 13,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["water","environment"],"row_index":443,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH - in H2O 4,5","parameters_en":[{"name":"Range","range":"2,0 - 13,0"}],"search_en":"pH - in H2O 4,5 Potentiometric method Range PN-EN ISO 10390:2022-09","technique_en":"Potentiometric method","parameters_zh":[{"name":"范围","range":"2,0 - 13,0"}],"search_zh":"电位法 范围 PN-EN ISO 10390:2022-09","technique_zh":"电位法"},{"_id":"6a8369ecaf14b9c0e7b1ddde","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Odpady kod E: 02 01 03, 02 03 01, 02 03 80, 10 01 01, 17 01 07, 17 01 80, 17 01 81, 17 01 82, 17 03 02, 17 03 80, 17 06 04, 17 09 04, 19 01 12, 19 06 04, 19 08 02, 19 09 01, 19 09 02, 19 12 09, 20 03 06, Odpady DAB-11: E - Odpady z przetwarzania odpadów (VI) - Osady ściekowe (IX) - Tworzywa sztuczne (XXV) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII)","methodology":"Stężenie/zawartość pierwiastków","parameters":[],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) 1,2,3,4","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) 1,2,3,4"],"computed":[],"activity":"Stężenie/zawartość pierwiastków\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) 1,2,3,4","reference":"PN-EN ISO 17294 | PB-DAN-26","norm_bases":["PN-EN ISO 17294","PB-DAN-26"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: 1 - Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 roku w sprawie w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. z 2015, poz. 1277) 2 - Rozporządzeniem Ministra Środowiska z dnia 28 grudnia 2011 roku w sprawie w sprawie podziemnych składowisk odpadów (Dz. U. z 2011 nr 298, poz. 1771) 3 - Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2023. poz. 23) 4 - Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 roku w sprawie procesu R10 (Dz. U. z 2015, poz. 132) | Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. | Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11. | E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Odpady kod E: 02 01 03, 02 03 01, 02 03 80, 10 01 01, 17 01 07, 17 01 80, 17 01 81, 17 01 82, 17 03 02, 17 03 80, 17 06 04, 17 09 04, 19 01 12, 19 06 04, 19 08 02, 19 09 01, 19 09 02, 19 12 09, 20 03 06, Odpady DAB-11: E - Odpady z przetwarzania odpadów (VI) - Osady ściekowe (IX) - Tworzywa sztuczne (XXV) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII) Stężenie/zawartość pierwiastków\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) 1,2,3,4 PN-EN ISO 17294 | PB-DAN-26 Odpady kod E: 02 01 03, 02 03 01, 02 03 80, 10 01 01, 17 01 07, 17 01 80, 17 01 81, 17 01 82, 17 03 02, 17 03 80, 17 06 04, 17 09 04, 19 01 12, 19 06 04, 19 08 02, 19 09 01, 19 09 02, 19 12 09, 20 03 06, Odpady DAB-11: E - Odpady z przetwarzania odpadow (VI) - Osady sciekowe (IX) - Tworzywa sztuczne (XXV) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII) Stezenie/zawartosc pierwiastkow\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) 1,2,3,4 PN-EN ISO 17294 | PB-DAN-26","categories":["water","environment","materials"],"row_index":444,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element concentration/content","search_en":"Element concentration/content Inductively coupled plasma mass spectrometry method (ICP-MS) 1,2,3,4 PN-EN ISO 17294 | PB-DAN-26","technique_en":"Inductively coupled plasma mass spectrometry method (ICP-MS) 1,2,3,4","methodology_zh":"元素的浓度/含量","search_zh":"元素的浓度/含量 PN-EN ISO 17294 | PB-DAN-26"},{"_id":"6a8369ecaf14b9c0e7b1dddf","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Odpady DAB-11: E - Osady ściekowe (IX)","methodology":"Zawartość pierwiastków 1,2","parameters":[],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"computed":[],"activity":"Zawartość pierwiastków 1,2\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"P N -EN ISO 16965","norm_bases":["P N -EN ISO 16965"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: 1 - Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 roku w sprawie w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. z 2015, poz. 1277) 2 - Rozporządzeniem Ministra Środowiska z dnia 28 grudnia 2011 roku w sprawie w sprawie podziemnych składowisk odpadów (Dz. U. z 2011 nr 298, poz. 1771) 3 - Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2023. poz. 23) 4 - Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 roku w sprawie procesu R10 (Dz. U. z 2015, poz. 132) | Badania wykonywane dla celów obszaru regulowanego objętego: 1 - Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2023r. poz. 23) 2 - Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 roku w sprawie procesu R10 (Dz. U. z 2015, poz. 132) | Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. | Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11. | E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Odpady DAB-11: E - Osady ściekowe (IX) Zawartość pierwiastków 1,2\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) P N -EN ISO 16965 Odpady DAB-11: E - Osady sciekowe (IX) Zawartosc pierwiastkow 1,2\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) P N -EN ISO 16965","categories":["water","environment"],"row_index":445,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Waste DAB-11: E - Sewage sludge (IX) Inductively coupled plasma mass spectrometry (ICP-MS) P N -EN ISO 16965","technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","test_object_en":"Waste DAB-11: E - Sewage sludge (IX)","search_zh":"电感耦合等离子体质谱法（ICP-MS） P N -EN ISO 16965","technique_zh":"电感耦合等离子体质谱法（ICP-MS）"},{"_id":"6a8369ecaf14b9c0e7b1dde0","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 - 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 - 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki pH\nZakres 4,0 - 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, Scieki pH\nZakres 4,0 - 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":446,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 - 10,0"}],"search_en":"Water, Wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water, Wastewater","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 - 10,0"}],"search_zh":"水、污水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、污水"},{"_id":"6a8369ecaf14b9c0e7b1dde1","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(10 - 15000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (10 - 15000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Nieorganicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Przewodność elektryczna właściwa\nZakres (10 - 15000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, Scieki Przewodnosc elektryczna wlasciwa\nZakres (10 - 15000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":447,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(10 - 15000) μS/cm"}],"search_en":"Water, Wastewater Electrical conductivity Conductometric method Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water, Wastewater","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(10 - 15000) μS/cm"}],"search_zh":"水、污水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、污水"},{"_id":"6a8369ecaf14b9c0e7b1dde2","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda (w tym, woda na pływalniach), Woda do spożycia przez ludzi, Ścieki","methodology":"Ogólna liczba mikroorganizmów w 22 °C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w 22 °C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym, woda na pływalniach), Woda do spożycia przez ludzi, Ścieki Ogólna liczba mikroorganizmów w 22 °C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda (w tym, woda na plywalniach), Woda do spozycia przez ludzi, Scieki Ogolna liczba mikroorganizmow w 22 °C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":448,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total viable count at 22 °C","search_en":"Water (including swimming pool water), Water intended for human consumption, Wastewater Total viable count at 22 °C Plate method (pour plate) PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water (including swimming pool water), Water intended for human consumption, Wastewater","methodology_zh":"22 °C 微生物总数","search_zh":"水（含游泳池水）、生活饮用水、废水 22 °C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水（含游泳池水）、生活饮用水、废水"},{"_id":"6a8369ecaf14b9c0e7b1dde3","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda (w tym, woda na pływalniach), Woda do spożycia przez ludzi, Ścieki","methodology":"Ogólna liczba mikroorganizmów w 36 °C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w 36 °C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym, woda na pływalniach), Woda do spożycia przez ludzi, Ścieki Ogólna liczba mikroorganizmów w 36 °C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda (w tym, woda na plywalniach), Woda do spozycia przez ludzi, Scieki Ogolna liczba mikroorganizmow w 36 °C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":449,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total viable count at 36 °C","search_en":"Water (including swimming pool water), Water intended for human consumption, Wastewater Total viable count at 36 °C Plate method (pour plate) PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water (including swimming pool water), Water intended for human consumption, Wastewater","methodology_zh":"36 °C 微生物总数","search_zh":"水（含游泳池水）、生活饮用水、废水 36 °C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水（含游泳池水）、生活饮用水、废水"},{"_id":"6a8369ecaf14b9c0e7b1dde4","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda (w tym, woda na pływalniach), Woda do spożycia przez ludzi, Ścieki","methodology":"Najbardziej prawdopodobna liczba bakterii grupy coli, Escherichia coli","parameters":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"computed":[],"activity":"Najbardziej prawdopodobna liczba bakterii grupy coli, Escherichia coli\nMetoda NPL","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym, woda na pływalniach), Woda do spożycia przez ludzi, Ścieki Najbardziej prawdopodobna liczba bakterii grupy coli, Escherichia coli\nMetoda NPL PN-EN ISO 9308-2:2014-06 Woda (w tym, woda na plywalniach), Woda do spozycia przez ludzi, Scieki Najbardziej prawdopodobna liczba bakterii grupy coli, Escherichia coli\nMetoda NPL PN-EN ISO 9308-2:2014-06","categories":["water","microbiology"],"row_index":450,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Most probable number of coliform bacteria, Escherichia coli","search_en":"Water (including swimming pool water), Water intended for human consumption, Wastewater Most probable number of coliform bacteria, Escherichia coli MPN method PN-EN ISO 9308-2:2014-06","technique_en":"MPN method","test_object_en":"Water (including swimming pool water), Water intended for human consumption, Wastewater","search_zh":"水（含游泳池水）、生活饮用水、废水 大肠菌群、大肠埃希氏菌最可能数 最可能数法（MPN） PN-EN ISO 9308-2:2014-06","technique_zh":"最可能数法（MPN）","test_object_zh":"水（含游泳池水）、生活饮用水、废水","methodology_zh":"大肠菌群、大肠埃希氏菌最可能数"},{"_id":"6a8369ecaf14b9c0e7b1dde5","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda (w tym, woda na pływalniach), Woda do spożycia przez ludzi, Ścieki","methodology":"Najbardziej prawdopodobna liczba enterokoków kałowych","parameters":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"computed":[],"activity":"Najbardziej prawdopodobna liczba enterokoków kałowych\nMetoda NPL","reference":"PN-EN ISO 7899-3:2025-11","norm_bases":["PN-EN ISO 7899-3:2025-11"],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym, woda na pływalniach), Woda do spożycia przez ludzi, Ścieki Najbardziej prawdopodobna liczba enterokoków kałowych\nMetoda NPL PN-EN ISO 7899-3:2025-11 Woda (w tym, woda na plywalniach), Woda do spozycia przez ludzi, Scieki Najbardziej prawdopodobna liczba enterokokow kalowych\nMetoda NPL PN-EN ISO 7899-3:2025-11","categories":["water"],"row_index":451,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Most probable number of intestinal enterococci","search_en":"Water (including swimming pool water), Water intended for human consumption, Wastewater Most probable number of intestinal enterococci MPN method PN-EN ISO 7899-3:2025-11","technique_en":"MPN method","test_object_en":"Water (including swimming pool water), Water intended for human consumption, Wastewater","search_zh":"水（含游泳池水）、生活饮用水、废水 粪肠球菌最可能数 最可能数法（MPN） PN-EN ISO 7899-3:2025-11","technique_zh":"最可能数法（MPN）","methodology_zh":"粪肠球菌最可能数","test_object_zh":"水（含游泳池水）、生活饮用水、废水"},{"_id":"6a8369ecaf14b9c0e7b1dde6","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda (w tym, woda na pływalniach), Woda do spożycia przez ludzi, Ścieki","methodology":"Obecność Salmonella spp.","parameters":[],"technique":"Metoda filtracji membranowej z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda filtracji membranowej z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność Salmonella spp.\nMetoda filtracji membranowej z potwierdzeniem biochemicznym i serologicznym","reference":"PN-EN ISO 19250:2013-07","norm_bases":["PN-EN ISO 19250:2013-07"],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym, woda na pływalniach), Woda do spożycia przez ludzi, Ścieki Obecność Salmonella spp.\nMetoda filtracji membranowej z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 19250:2013-07 Woda (w tym, woda na plywalniach), Woda do spozycia przez ludzi, Scieki Obecnosc Salmonella spp.\nMetoda filtracji membranowej z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 19250:2013-07","categories":["water","microbiology"],"row_index":452,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of Salmonella spp.","search_en":"Water (including swimming pool water), Water intended for human consumption, Wastewater Presence of Salmonella spp. Membrane filtration method with biochemical and serological confirmation PN-EN ISO 19250:2013-07","technique_en":"Membrane filtration method with biochemical and serological confirmation","test_object_en":"Water (including swimming pool water), Water intended for human consumption, Wastewater","methodology_zh":"沙门氏菌属（Salmonella spp.）的检出","search_zh":"水（含游泳池水）、生活饮用水、废水 沙门氏菌属（Salmonella spp.）的检出 PN-EN ISO 19250:2013-07","test_object_zh":"水（含游泳池水）、生活饮用水、废水"},{"_id":"6a8369ecaf14b9c0e7b1dde7","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda (w tym, woda na pływalniach), Woda do spożycia przez ludzi, Ścieki","methodology":"Najbardziej prawdopodobna liczba bakterii grupy coli typ fekalny","parameters":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"computed":[],"activity":"Najbardziej prawdopodobna liczba bakterii grupy coli typ fekalny\nMetoda NPL","reference":"PB-DMP-64-2 wersja 01 z dnia 25.02.2021 r.","norm_bases":["PB-DMP-64-2 wersja 01 z dnia 25.02.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym, woda na pływalniach), Woda do spożycia przez ludzi, Ścieki Najbardziej prawdopodobna liczba bakterii grupy coli typ fekalny\nMetoda NPL PB-DMP-64-2 wersja 01 z dnia 25.02.2021 r. Woda (w tym, woda na plywalniach), Woda do spozycia przez ludzi, Scieki Najbardziej prawdopodobna liczba bakterii grupy coli typ fekalny\nMetoda NPL PB-DMP-64-2 wersja 01 z dnia 25.02.2021 r.","categories":["water","microbiology"],"row_index":453,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Water (including swimming pool water), Water intended for human consumption, Wastewater MPN method PB-DMP-64-2 wersja 01 z dnia 25.02.2021 r.","technique_en":"MPN method","test_object_en":"Water (including swimming pool water), Water intended for human consumption, Wastewater","search_zh":"水（含游泳池水）、生活饮用水、废水 最可能数法（MPN） PB-DMP-64-2 wersja 01 z dnia 25.02.2021 r.","technique_zh":"最可能数法（MPN）","test_object_zh":"水（含游泳池水）、生活饮用水、废水"},{"_id":"6a8369ecaf14b9c0e7b1dde8","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda (w tym, woda na pływalniach), Woda do spożycia przez ludzi, Ścieki","methodology":"Ogólna liczba mikroorganizmów w 36 °C po 24 h","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w 36 °C po 24 h\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym, woda na pływalniach), Woda do spożycia przez ludzi, Ścieki Ogólna liczba mikroorganizmów w 36 °C po 24 h\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda (w tym, woda na plywalniach), Woda do spozycia przez ludzi, Scieki Ogolna liczba mikroorganizmow w 36 °C po 24 h\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":454,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Water (including swimming pool water), Water intended for human consumption, Wastewater Plate method (pour plate) PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water (including swimming pool water), Water intended for human consumption, Wastewater","search_zh":"水（含游泳池水）、生活饮用水、废水 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水（含游泳池水）、生活饮用水、废水"},{"_id":"6a8369ecaf14b9c0e7b1dde9","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda (w tym, woda na pływalniach), Woda do spożycia przez ludzi, Ścieki","methodology":"Liczba bakterii grupy coli, Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii grupy coli, Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2004+Ap1:2005 +AC:2009 | PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2004+Ap1:2005 +AC:2009","PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym, woda na pływalniach), Woda do spożycia przez ludzi, Ścieki Liczba bakterii grupy coli, Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2004+Ap1:2005 +AC:2009 | PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda (w tym, woda na plywalniach), Woda do spozycia przez ludzi, Scieki Liczba bakterii grupy coli, Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2004+Ap1:2005 +AC:2009 | PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":455,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Coliform bacteria count, Escherichia coli","search_en":"Water (including swimming pool water), Water intended for human consumption, Wastewater Coliform bacteria count, Escherichia coli Membrane filtration method PN-EN ISO 9308-1:2004+Ap1:2005 +AC:2009 | PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water (including swimming pool water), Water intended for human consumption, Wastewater","search_zh":"水（含游泳池水）、生活饮用水、废水 大肠菌群数、大肠埃希氏菌数 膜过滤法 PN-EN ISO 9308-1:2004+Ap1:2005 +AC:2009 | PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","methodology_zh":"大肠菌群数、大肠埃希氏菌数","test_object_zh":"水（含游泳池水）、生活饮用水、废水"},{"_id":"6a8369ecaf14b9c0e7b1ddea","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda z kąpielisk","methodology":"Najbardziej prawdopodobna liczba, Escherichia coli","parameters":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"computed":[],"activity":"Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda NPL","reference":"PN-EN-ISO 9308-3:2002","norm_bases":["PN-EN-ISO 9308-3:2002"],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda z kąpielisk Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda NPL PN-EN-ISO 9308-3:2002 Woda z kapielisk Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda NPL PN-EN-ISO 9308-3:2002","categories":["water","microbiology"],"row_index":456,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Most probable number, Escherichia coli","search_en":"Bathing water Most probable number, Escherichia coli MPN method PN-EN-ISO 9308-3:2002","technique_en":"MPN method","test_object_en":"Bathing water","methodology_zh":"大肠埃希氏菌（Escherichia coli）最可能数（MPN）","search_zh":"浴场水 大肠埃希氏菌（Escherichia coli）最可能数（MPN） 最可能数法（MPN） PN-EN-ISO 9308-3:2002","technique_zh":"最可能数法（MPN）","test_object_zh":"浴场水"},{"_id":"6a8369ecaf14b9c0e7b1ddeb","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda z kąpielisk","methodology":"Najbardziej prawdopodobna liczba enterokoków kałowych","parameters":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"computed":[],"activity":"Najbardziej prawdopodobna liczba enterokoków kałowych\nMetoda NPL","reference":"PN-EN-ISO 7899-1:2002","norm_bases":["PN-EN-ISO 7899-1:2002"],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda z kąpielisk Najbardziej prawdopodobna liczba enterokoków kałowych\nMetoda NPL PN-EN-ISO 7899-1:2002 Woda z kapielisk Najbardziej prawdopodobna liczba enterokokow kalowych\nMetoda NPL PN-EN-ISO 7899-1:2002","categories":["water"],"row_index":457,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Most probable number of intestinal enterococci","search_en":"Bathing water Most probable number of intestinal enterococci MPN method PN-EN-ISO 7899-1:2002","technique_en":"MPN method","test_object_en":"Bathing water","search_zh":"浴场水 粪肠球菌最可能数 最可能数法（MPN） PN-EN-ISO 7899-1:2002","technique_zh":"最可能数法（MPN）","methodology_zh":"粪肠球菌最可能数","test_object_zh":"浴场水"},{"_id":"6a8369ecaf14b9c0e7b1ddec","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Ścieki","methodology":"Obecność Salmonella spp.","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność Salmonella spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PN-EN ISO 6579-1:2017-04+ A1:2020-09","norm_bases":["PN-EN ISO 6579-1:2017-04+ A1:2020-09"],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Obecność Salmonella spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579-1:2017-04+ A1:2020-09 Scieki Obecnosc Salmonella spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579-1:2017-04+ A1:2020-09","categories":["microbiology","water"],"row_index":458,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of Salmonella spp.","search_en":"Wastewater Presence of Salmonella spp. Culture method with biochemical and serological confirmation PN-EN ISO 6579-1:2017-04+ A1:2020-09","technique_en":"Culture method with biochemical and serological confirmation","test_object_en":"Wastewater","methodology_zh":"沙门氏菌属（Salmonella spp.）的检出","search_zh":"污水 沙门氏菌属（Salmonella spp.）的检出 培养法结合生化与血清学确认 PN-EN ISO 6579-1:2017-04+ A1:2020-09","technique_zh":"培养法结合生化与血清学确认","test_object_zh":"污水"},{"_id":"6a8369ecaf14b9c0e7b1dded","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda (w tym, woda na pływalniach), Woda do spożycia przez ludzi","methodology":"Liczba Legionella sp.","parameters":[{"name":"Matryca B Procedura 8,9,10 (pożywka C – GVPC)"}],"technique":"Metoda filtracji membranowej z wymywaniem","techniques":["Metoda filtracji membranowej z wymywaniem"],"computed":[],"activity":"Liczba Legionella sp.\nMatryca B Procedura 8,9,10 (pożywka C – GVPC)\nMetoda filtracji membranowej z wymywaniem","reference":"PN-EN ISO 11731:2017-08","norm_bases":["PN-EN ISO 11731:2017-08"],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym, woda na pływalniach), Woda do spożycia przez ludzi Liczba Legionella sp.\nMatryca B Procedura 8,9,10 (pożywka C – GVPC)\nMetoda filtracji membranowej z wymywaniem PN-EN ISO 11731:2017-08 Woda (w tym, woda na plywalniach), Woda do spozycia przez ludzi Liczba Legionella sp.\nMatryca B Procedura 8,9,10 (pozywka C – GVPC)\nMetoda filtracji membranowej z wymywaniem PN-EN ISO 11731:2017-08","categories":["microbiology","water"],"row_index":459,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Legionella sp. count","parameters_en":[{"name":"Matrix B Procedure 8,9,10 (medium C – GVPC)"}],"search_en":"Water (including swimming pool water), Water intended for human consumption Legionella sp. count Membrane filtration method with elution Matrix B Procedure 8,9,10 (medium C – GVPC) PN-EN ISO 11731:2017-08","technique_en":"Membrane filtration method with elution","test_object_en":"Water (including swimming pool water), Water intended for human consumption","methodology_zh":"军团菌属计数","search_zh":"水（含游泳池水）、生活饮用水 军团菌属计数 膜过滤-洗脱法 PN-EN ISO 11731:2017-08","test_object_zh":"水（含游泳池水）、生活饮用水","technique_zh":"膜过滤-洗脱法"},{"_id":"6a8369ecaf14b9c0e7b1ddee","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda (w tym, woda na pływalniach), Woda do spożycia przez ludzi","methodology":"Liczba Legionella sp., Matryca A, Procedura 5, 7 (pożywka A – BCYE, pożywka C – GVPC)","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Legionella sp., Matryca A, Procedura 5, 7 (pożywka A – BCYE, pożywka C – GVPC)\nMetoda filtracji membranowej","reference":"PN-EN ISO 11731:2017-08","norm_bases":["PN-EN ISO 11731:2017-08"],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym, woda na pływalniach), Woda do spożycia przez ludzi Liczba Legionella sp., Matryca A, Procedura 5, 7 (pożywka A – BCYE, pożywka C – GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 Woda (w tym, woda na plywalniach), Woda do spozycia przez ludzi Liczba Legionella sp., Matryca A, Procedura 5, 7 (pozywka A – BCYE, pozywka C – GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08","categories":["microbiology","water"],"row_index":460,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Legionella sp. count, Matrix A, Procedure 5, 7 (medium A – BCYE, medium C – GVPC)","search_en":"Water (including swimming pool water), Water intended for human consumption Legionella sp. count, Matrix A, Procedure 5, 7 (medium A – BCYE, medium C – GVPC) Membrane filtration method PN-EN ISO 11731:2017-08","technique_en":"Membrane filtration method","test_object_en":"Water (including swimming pool water), Water intended for human consumption","search_zh":"水（含游泳池水）、生活饮用水 膜过滤法 PN-EN ISO 11731:2017-08","technique_zh":"膜过滤法","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a8369ecaf14b9c0e7b1ddef","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda (w tym, woda na pływalniach), Woda do spożycia przez ludzi","methodology":"Liczba enterokoków kałowych","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba enterokoków kałowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym, woda na pływalniach), Woda do spożycia przez ludzi Liczba enterokoków kałowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda (w tym, woda na plywalniach), Woda do spozycia przez ludzi Liczba enterokokow kalowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":461,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Intestinal enterococci count","search_en":"Water (including swimming pool water), Water intended for human consumption Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004","technique_en":"Membrane filtration method","test_object_en":"Water (including swimming pool water), Water intended for human consumption","methodology_zh":"粪肠球菌计数","search_zh":"水（含游泳池水）、生活饮用水 粪肠球菌计数 膜过滤法 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a8369ecaf14b9c0e7b1ddf0","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda (w tym, woda na pływalniach), Woda do spożycia przez ludzi","methodology":"Liczba Clostridium perfringens (łącznie ze sporami)","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Clostridium perfringens (łącznie ze sporami)\nMetoda filtracji membranowej","reference":"PN-EN ISO 14189:2016-10","norm_bases":["PN-EN ISO 14189:2016-10"],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym, woda na pływalniach), Woda do spożycia przez ludzi Liczba Clostridium perfringens (łącznie ze sporami)\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10 Woda (w tym, woda na plywalniach), Woda do spozycia przez ludzi Liczba Clostridium perfringens (lacznie ze sporami)\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10","categories":["water"],"row_index":462,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Clostridium perfringens count (including spores)","search_en":"Water (including swimming pool water), Water intended for human consumption Clostridium perfringens count (including spores) Membrane filtration method PN-EN ISO 14189:2016-10","technique_en":"Membrane filtration method","test_object_en":"Water (including swimming pool water), Water intended for human consumption","search_zh":"水（含游泳池水）、生活饮用水 产气荚膜梭菌计数（含芽孢） 膜过滤法 PN-EN ISO 14189:2016-10","technique_zh":"膜过滤法","methodology_zh":"产气荚膜梭菌计数（含芽孢）","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a8369ecaf14b9c0e7b1ddf1","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda (w tym, woda na pływalniach), Woda do spożycia przez ludzi","methodology":"Liczba przetrwalników beztlenowców redukujących siarczyny (clostridia)","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba przetrwalników beztlenowców redukujących siarczyny (clostridia)\nMetoda filtracji membranowej","reference":"PN-EN 26461-2:2001","norm_bases":["PN-EN 26461-2:2001"],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym, woda na pływalniach), Woda do spożycia przez ludzi Liczba przetrwalników beztlenowców redukujących siarczyny (clostridia)\nMetoda filtracji membranowej PN-EN 26461-2:2001 Woda (w tym, woda na plywalniach), Woda do spozycia przez ludzi Liczba przetrwalnikow beztlenowcow redukujacych siarczyny (clostridia)\nMetoda filtracji membranowej PN-EN 26461-2:2001","categories":["water"],"row_index":463,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Count of spores of sulphite-reducing anaerobes (clostridia)","search_en":"Water (including swimming pool water), Water intended for human consumption Count of spores of sulphite-reducing anaerobes (clostridia) Membrane filtration method PN-EN 26461-2:2001","technique_en":"Membrane filtration method","test_object_en":"Water (including swimming pool water), Water intended for human consumption","search_zh":"水（含游泳池水）、生活饮用水 亚硫酸盐还原厌氧菌（梭菌）芽孢计数 膜过滤法 PN-EN 26461-2:2001","technique_zh":"膜过滤法","methodology_zh":"亚硫酸盐还原厌氧菌（梭菌）芽孢计数","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a8369ecaf14b9c0e7b1ddf2","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda (w tym, woda na pływalniach), Woda do spożycia przez ludzi","methodology":"Liczba gronkowców koagulazo-dodatnich","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba gronkowców koagulazo-dodatnich\nMetoda filtracji membranowej","reference":"PB-DMP-75 wersja 01 z dnia 25.02.2021 r.","norm_bases":["PB-DMP-75 wersja 01 z dnia 25.02.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym, woda na pływalniach), Woda do spożycia przez ludzi Liczba gronkowców koagulazo-dodatnich\nMetoda filtracji membranowej PB-DMP-75 wersja 01 z dnia 25.02.2021 r. Woda (w tym, woda na plywalniach), Woda do spozycia przez ludzi Liczba gronkowcow koagulazo-dodatnich\nMetoda filtracji membranowej PB-DMP-75 wersja 01 z dnia 25.02.2021 r.","categories":["water"],"row_index":464,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Coagulase-positive staphylococci count","search_en":"Water (including swimming pool water), Water intended for human consumption Coagulase-positive staphylococci count Membrane filtration method PB-DMP-75 wersja 01 z dnia 25.02.2021 r.","technique_en":"Membrane filtration method","test_object_en":"Water (including swimming pool water), Water intended for human consumption","search_zh":"水（含游泳池水）、生活饮用水 凝固酶阳性葡萄球菌计数 膜过滤法 PB-DMP-75 wersja 01 z dnia 25.02.2021 r.","technique_zh":"膜过滤法","methodology_zh":"凝固酶阳性葡萄球菌计数","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a8369ecaf14b9c0e7b1ddf3","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda (w tym, woda na pływalniach), Woda do spożycia przez ludzi","methodology":"Liczba Pseudomonas aeruginosa","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii","lab_address":null,"regulatory_area":"Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Woda (w tym, woda na pływalniach), Woda do spożycia przez ludzi Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009 Woda (w tym, woda na plywalniach), Woda do spozycia przez ludzi Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water"],"row_index":465,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Pseudomonas aeruginosa count","search_en":"Water (including swimming pool water), Water intended for human consumption Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009","technique_en":"Membrane filtration method","test_object_en":"Water (including swimming pool water), Water intended for human consumption","methodology_zh":"铜绿假单胞菌计数","search_zh":"水（含游泳池水）、生活饮用水 铜绿假单胞菌计数 膜过滤法 PN-EN ISO 16266:2009","technique_zh":"膜过滤法","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a8369ecaf14b9c0e7b1ddf4","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda (w tym, woda na pływalniach), Woda do spożycia przez ludzi","methodology":"Liczba Pseudomonas aeruginosa","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PB-DMP-79 wersja 01 z dnia 25.02.2021 r.","norm_bases":["PB-DMP-79 wersja 01 z dnia 25.02.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii","lab_address":null,"regulatory_area":"Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Woda (w tym, woda na pływalniach), Woda do spożycia przez ludzi Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PB-DMP-79 wersja 01 z dnia 25.02.2021 r. Woda (w tym, woda na plywalniach), Woda do spozycia przez ludzi Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PB-DMP-79 wersja 01 z dnia 25.02.2021 r.","categories":["water"],"row_index":466,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Pseudomonas aeruginosa count","search_en":"Water (including swimming pool water), Water intended for human consumption Pseudomonas aeruginosa count Membrane filtration method PB-DMP-79 wersja 01 z dnia 25.02.2021 r.","technique_en":"Membrane filtration method","test_object_en":"Water (including swimming pool water), Water intended for human consumption","methodology_zh":"铜绿假单胞菌计数","search_zh":"水（含游泳池水）、生活饮用水 铜绿假单胞菌计数 膜过滤法 PB-DMP-79 wersja 01 z dnia 25.02.2021 r.","technique_zh":"膜过滤法","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a8369ecaf14b9c0e7b1ddf5","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda (w tym, woda na pływalniach), Woda do spożycia przez ludzi","methodology":"Liczba bakterii grupy coli typ fekalny","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii grupy coli typ fekalny\nMetoda filtracji membranowej","reference":"PB-DMP-81 wersja 01 z dnia 25.02.2021 r.","norm_bases":["PB-DMP-81 wersja 01 z dnia 25.02.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii","lab_address":null,"regulatory_area":"Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Woda (w tym, woda na pływalniach), Woda do spożycia przez ludzi Liczba bakterii grupy coli typ fekalny\nMetoda filtracji membranowej PB-DMP-81 wersja 01 z dnia 25.02.2021 r. Woda (w tym, woda na plywalniach), Woda do spozycia przez ludzi Liczba bakterii grupy coli typ fekalny\nMetoda filtracji membranowej PB-DMP-81 wersja 01 z dnia 25.02.2021 r.","categories":["water","microbiology"],"row_index":467,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Faecal-type coliform bacteria count","search_en":"Water (including swimming pool water), Water intended for human consumption Faecal-type coliform bacteria count Membrane filtration method PB-DMP-81 wersja 01 z dnia 25.02.2021 r.","technique_en":"Membrane filtration method","test_object_en":"Water (including swimming pool water), Water intended for human consumption","search_zh":"水（含游泳池水）、生活饮用水 膜过滤法 PB-DMP-81 wersja 01 z dnia 25.02.2021 r.","technique_zh":"膜过滤法","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a8369ecaf14b9c0e7b1ddf6","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Gleba, Osady ściekowe","methodology":"Liczba bakterii grupy coli","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba bakterii grupy coli\nMetoda płytkowa (posiew wgłębny)","reference":"PN-ISO 4832:2007","norm_bases":["PN-ISO 4832:2007"],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii","lab_address":null,"regulatory_area":"Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Gleba, Osady ściekowe Liczba bakterii grupy coli\nMetoda płytkowa (posiew wgłębny) PN-ISO 4832:2007 Gleba, Osady sciekowe Liczba bakterii grupy coli\nMetoda plytkowa (posiew wglebny) PN-ISO 4832:2007","categories":["water","environment","microbiology"],"row_index":468,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Coliform bacteria count","search_en":"Soil, Sewage sludge Coliform bacteria count Plate method (pour plate) PN-ISO 4832:2007","technique_en":"Plate method (pour plate)","test_object_en":"Soil, Sewage sludge","methodology_zh":"大肠菌群计数","search_zh":"土壤、污泥 大肠菌群计数 平板法（倾注培养） PN-ISO 4832:2007","technique_zh":"平板法（倾注培养）","test_object_zh":"土壤、污泥"},{"_id":"6a8369ecaf14b9c0e7b1ddf7","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Gleba, Osady ściekowe","methodology":"Liczba Enterobacteriaceae","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba Enterobacteriaceae\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 21528-2:2017-08","norm_bases":["PN-EN ISO 21528-2:2017-08"],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii","lab_address":null,"regulatory_area":"Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Gleba, Osady ściekowe Liczba Enterobacteriaceae\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 21528-2:2017-08 Gleba, Osady sciekowe Liczba Enterobacteriaceae\nMetoda plytkowa (posiew wglebny) PN-EN ISO 21528-2:2017-08","categories":["water","environment"],"row_index":469,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Enterobacteriaceae count","search_en":"Soil, Sewage sludge Enterobacteriaceae count Plate method (pour plate) PN-EN ISO 21528-2:2017-08","technique_en":"Plate method (pour plate)","test_object_en":"Soil, Sewage sludge","methodology_zh":"肠杆菌科（Enterobacteriaceae）计数","search_zh":"土壤、污泥 肠杆菌科（Enterobacteriaceae）计数 平板法（倾注培养） PN-EN ISO 21528-2:2017-08","technique_zh":"平板法（倾注培养）","test_object_zh":"土壤、污泥"},{"_id":"6a8369ecaf14b9c0e7b1ddf8","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Gleba, Osady ściekowe","methodology":"Liczba bakterii grupy coli typ fekalny","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba bakterii grupy coli typ fekalny\nMetoda płytkowa (posiew wgłębny)","reference":"PB-DMP-73 wersja 01 z dnia 25.02.2021 r.","norm_bases":["PB-DMP-73 wersja 01 z dnia 25.02.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii","lab_address":null,"regulatory_area":"Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Gleba, Osady ściekowe Liczba bakterii grupy coli typ fekalny\nMetoda płytkowa (posiew wgłębny) PB-DMP-73 wersja 01 z dnia 25.02.2021 r. Gleba, Osady sciekowe Liczba bakterii grupy coli typ fekalny\nMetoda plytkowa (posiew wglebny) PB-DMP-73 wersja 01 z dnia 25.02.2021 r.","categories":["water","environment","microbiology"],"row_index":470,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Faecal-type coliform bacteria count","search_en":"Soil, Sewage sludge Faecal-type coliform bacteria count Plate method (pour plate) PB-DMP-73 wersja 01 z dnia 25.02.2021 r.","technique_en":"Plate method (pour plate)","test_object_en":"Soil, Sewage sludge","search_zh":"土壤、污泥 平板法（倾注培养） PB-DMP-73 wersja 01 z dnia 25.02.2021 r.","technique_zh":"平板法（倾注培养）","test_object_zh":"土壤、污泥"},{"_id":"6a8369ecaf14b9c0e7b1ddf9","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Gleba, Osady ściekowe","methodology":"Liczba Escherichia coli","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba Escherichia coli\nMetoda płytkowa (posiew wgłębny)","reference":"PN-ISO 16649-2:2004","norm_bases":["PN-ISO 16649-2:2004"],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii","lab_address":null,"regulatory_area":"Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Gleba, Osady ściekowe Liczba Escherichia coli\nMetoda płytkowa (posiew wgłębny) PN-ISO 16649-2:2004 Gleba, Osady sciekowe Liczba Escherichia coli\nMetoda plytkowa (posiew wglebny) PN-ISO 16649-2:2004","categories":["water","environment","microbiology"],"row_index":471,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Escherichia coli count","search_en":"Soil, Sewage sludge Escherichia coli count Plate method (pour plate) PN-ISO 16649-2:2004","technique_en":"Plate method (pour plate)","test_object_en":"Soil, Sewage sludge","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"土壤、污泥 大肠埃希氏菌（Escherichia coli）计数 平板法（倾注培养） PN-ISO 16649-2:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"土壤、污泥"},{"_id":"6a8369ecaf14b9c0e7b1ddfa","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Gleba, Osady ściekowe, Odpady kod: 02 01 01, 02 01 03, 02 01 06, 02 01 07, 02 01 83, 02 02 04, 02 03 05, 02 05 02 02 06 03, 02 07 05, 02 04 03, 17 05 04, 17 05 06, 19 03 05, 19 05 01, 19 05 02, 19 05 03, 19 08 01, 19 08 02, 19 08 05, 19 08 12, 19 09 01, 19 13 04, 19 13 06, 20 02 01, 20 02 02, 20 03 04, 20 03 06","methodology":"Obecność Salmonella spp.","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność Salmonella spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PN-EN ISO 6579-1:2017-04 +A1:2020-09","norm_bases":["PN-EN ISO 6579-1:2017-04 +A1:2020-09"],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii","lab_address":null,"regulatory_area":"Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Gleba, Osady ściekowe, Odpady kod: 02 01 01, 02 01 03, 02 01 06, 02 01 07, 02 01 83, 02 02 04, 02 03 05, 02 05 02 02 06 03, 02 07 05, 02 04 03, 17 05 04, 17 05 06, 19 03 05, 19 05 01, 19 05 02, 19 05 03, 19 08 01, 19 08 02, 19 08 05, 19 08 12, 19 09 01, 19 13 04, 19 13 06, 20 02 01, 20 02 02, 20 03 04, 20 03 06 Obecność Salmonella spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579-1:2017-04 +A1:2020-09 Gleba, Osady sciekowe, Odpady kod: 02 01 01, 02 01 03, 02 01 06, 02 01 07, 02 01 83, 02 02 04, 02 03 05, 02 05 02 02 06 03, 02 07 05, 02 04 03, 17 05 04, 17 05 06, 19 03 05, 19 05 01, 19 05 02, 19 05 03, 19 08 01, 19 08 02, 19 08 05, 19 08 12, 19 09 01, 19 13 04, 19 13 06, 20 02 01, 20 02 02, 20 03 04, 20 03 06 Obecnosc Salmonella spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579-1:2017-04 +A1:2020-09","categories":["environment","water","microbiology"],"row_index":472,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of Salmonella spp.","search_en":"Soil, Sewage sludge, Waste code: 02 01 01, 02 01 03, 02 01 06, 02 01 07, 02 01 83, 02 02 04, 02 03 05, 02 05 02 02 06 03, 02 07 05, 02 04 03, 17 05 04, 17 05 06, 19 03 05, 19 05 01, 19 05 02, 19 05 03, 19 08 01, 19 08 02, 19 08 05, 19 08 12, 19 09 01, 19 13 04, 19 13 06, 20 02 01, 20 02 02, 20 03 04, 20 03 06 Presence of Salmonella spp. Culture method with biochemical and serological confirmation PN-EN ISO 6579-1:2017-04 +A1:2020-09","technique_en":"Culture method with biochemical and serological confirmation","test_object_en":"Soil, Sewage sludge, Waste code: 02 01 01, 02 01 03, 02 01 06, 02 01 07, 02 01 83, 02 02 04, 02 03 05, 02 05 02 02 06 03, 02 07 05, 02 04 03, 17 05 04, 17 05 06, 19 03 05, 19 05 01, 19 05 02, 19 05 03, 19 08 01, 19 08 02, 19 08 05, 19 08 12, 19 09 01, 19 13 04, 19 13 06, 20 02 01, 20 02 02, 20 03 04, 20 03 06","methodology_zh":"沙门氏菌属（Salmonella spp.）的检出","search_zh":"沙门氏菌属（Salmonella spp.）的检出 培养法结合生化与血清学确认 PN-EN ISO 6579-1:2017-04 +A1:2020-09","technique_zh":"培养法结合生化与血清学确认"},{"_id":"6a8369ecaf14b9c0e7b1ddfb","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Gleba, Osady ściekowe, Odpady kod: 19 08 05, 02 02 04, 02 03 05, 02 05 02, 02 06 03, 02 07 05, 02 04 03","methodology":"Obecność specyficznego DNA, Salmonella spp.","parameters":[],"technique":"Metoda Real-time PCR","techniques":["Metoda Real-time PCR"],"computed":[],"activity":"Obecność specyficznego DNA, Salmonella spp.\nMetoda Real-time PCR","reference":"PB-DMP-78 wersja 01 z dnia 25.02.2021 r.","norm_bases":["PB-DMP-78 wersja 01 z dnia 25.02.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii","lab_address":null,"regulatory_area":"Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Gleba, Osady ściekowe, Odpady kod: 19 08 05, 02 02 04, 02 03 05, 02 05 02, 02 06 03, 02 07 05, 02 04 03 Obecność specyficznego DNA, Salmonella spp.\nMetoda Real-time PCR PB-DMP-78 wersja 01 z dnia 25.02.2021 r. Gleba, Osady sciekowe, Odpady kod: 19 08 05, 02 02 04, 02 03 05, 02 05 02, 02 06 03, 02 07 05, 02 04 03 Obecnosc specyficznego DNA, Salmonella spp.\nMetoda Real-time PCR PB-DMP-78 wersja 01 z dnia 25.02.2021 r.","categories":["environment","water","microbiology"],"row_index":473,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of specific DNA, Salmonella spp.","search_en":"Soil, Sewage sludge, Waste code: 19 08 05, 02 02 04, 02 03 05, 02 05 02, 02 06 03, 02 07 05, 02 04 03 Presence of specific DNA, Salmonella spp. Real-time PCR method PB-DMP-78 wersja 01 z dnia 25.02.2021 r.","technique_en":"Real-time PCR method","test_object_en":"Soil, Sewage sludge, Waste code: 19 08 05, 02 02 04, 02 03 05, 02 05 02, 02 06 03, 02 07 05, 02 04 03","search_zh":"特定 DNA 的检出，沙门氏菌属（Salmonella spp.） 实时荧光定量 PCR 法 PB-DMP-78 wersja 01 z dnia 25.02.2021 r.","technique_zh":"实时荧光定量 PCR 法","methodology_zh":"特定 DNA 的检出，沙门氏菌属（Salmonella spp.）"},{"_id":"6a8369ecaf14b9c0e7b1ddfc","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Gleba, Osady ściekowe, Odpady kod: 19 08 05, 02 02 04, 02 03 05, 02 05 02, 02 06 03, 02 07 05","methodology":"Liczba żywych jaj pasożytów jelitowych Ascaris sp., Trichuris sp., Toxocara sp.","parameters":[{"name":"Zakres","range":"od 1 szt./100 g"},{"name":"Obecność żywych jaj pasożytów jelitowych Ascaris sp., Trichuris sp., Toxocara sp. w 100 g"}],"technique":"Metoda mikroskopowa","techniques":["Metoda mikroskopowa"],"computed":[],"activity":"Liczba żywych jaj pasożytów jelitowych Ascaris sp., Trichuris sp., Toxocara sp.\nZakres:\nZakres od 1 szt./100 g\nObecność żywych jaj pasożytów jelitowych Ascaris sp., Trichuris sp., Toxocara sp. w 100 g\nMetoda mikroskopowa","reference":"PB-DMP-77 wersja 01 z dnia 25.02.2021 r.","norm_bases":["PB-DMP-77 wersja 01 z dnia 25.02.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii","lab_address":null,"regulatory_area":"Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Gleba, Osady ściekowe, Odpady kod: 19 08 05, 02 02 04, 02 03 05, 02 05 02, 02 06 03, 02 07 05 Liczba żywych jaj pasożytów jelitowych Ascaris sp., Trichuris sp., Toxocara sp.\nZakres:\nZakres od 1 szt./100 g\nObecność żywych jaj pasożytów jelitowych Ascaris sp., Trichuris sp., Toxocara sp. w 100 g\nMetoda mikroskopowa PB-DMP-77 wersja 01 z dnia 25.02.2021 r. Gleba, Osady sciekowe, Odpady kod: 19 08 05, 02 02 04, 02 03 05, 02 05 02, 02 06 03, 02 07 05 Liczba zywych jaj pasozytow jelitowych Ascaris sp., Trichuris sp., Toxocara sp.\nZakres:\nZakres od 1 szt./100 g\nObecnosc zywych jaj pasozytow jelitowych Ascaris sp., Trichuris sp., Toxocara sp. w 100 g\nMetoda mikroskopowa PB-DMP-77 wersja 01 z dnia 25.02.2021 r.","categories":["environment","water"],"row_index":474,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Count of viable eggs of intestinal parasites Ascaris sp., Trichuris sp., Toxocara sp.","parameters_en":[{"name":"Range","range":"od 1 szt./100 g"},{"name":"Presence of live eggs of intestinal parasites Ascaris sp., Trichuris sp., Toxocara sp. in 100 g"}],"search_en":"Soil, Sewage sludge, Waste code: 19 08 05, 02 02 04, 02 03 05, 02 05 02, 02 06 03, 02 07 05 Count of viable eggs of intestinal parasites Ascaris sp., Trichuris sp., Toxocara sp. Microscopic method Range Presence of live eggs of intestinal parasites Ascaris sp., Trichuris sp., Toxocara sp. in 100 g PB-DMP-77 wersja 01 z dnia 25.02.2021 r.","technique_en":"Microscopic method","test_object_en":"Soil, Sewage sludge, Waste code: 19 08 05, 02 02 04, 02 03 05, 02 05 02, 02 06 03, 02 07 05","parameters_zh":[{"name":"范围","range":"od 1 szt./100 g"},{"name":"Obecność żywych jaj pasożytów jelitowych Ascaris sp., Trichuris sp., Toxocara sp. w 100 g"}],"search_zh":"显微镜法 范围 PB-DMP-77 wersja 01 z dnia 25.02.2021 r.","technique_zh":"显微镜法"},{"_id":"6a8369ecaf14b9c0e7b1ddfd","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Nawozy: - naturalne, - organiczne, w tym kompost, organiczno-mineralne, Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby, - stymulatory wzrostu, - podłoża do upraw","methodology":"Obecność Salmonella spp.","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność Salmonella spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PN-EN ISO 6579-1:2017-04 +A1:2020-09","norm_bases":["PN-EN ISO 6579-1:2017-04 +A1:2020-09"],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii","lab_address":null,"regulatory_area":"Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Nawozy: - naturalne, - organiczne, w tym kompost, organiczno-mineralne, Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby, - stymulatory wzrostu, - podłoża do upraw Obecność Salmonella spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579-1:2017-04 +A1:2020-09 Nawozy: - naturalne, - organiczne, w tym kompost, organiczno-mineralne, Srodki wspomagajace uprawe roslin: - srodki poprawiajace wlasciwosci gleby, - stymulatory wzrostu, - podloza do upraw Obecnosc Salmonella spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579-1:2017-04 +A1:2020-09","categories":["microbiology"],"row_index":475,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of Salmonella spp.","search_en":"Fertilisers: - natural, - organic, including compost, organic-mineral, Plant cultivation aids: - soil improvers, - growth stimulants, - growing media Presence of Salmonella spp. Culture method with biochemical and serological confirmation PN-EN ISO 6579-1:2017-04 +A1:2020-09","technique_en":"Culture method with biochemical and serological confirmation","test_object_en":"Fertilisers: - natural, - organic, including compost, organic-mineral, Plant cultivation aids: - soil improvers, - growth stimulants, - growing media","methodology_zh":"沙门氏菌属（Salmonella spp.）的检出","search_zh":"沙门氏菌属（Salmonella spp.）的检出 培养法结合生化与血清学确认 PN-EN ISO 6579-1:2017-04 +A1:2020-09","technique_zh":"培养法结合生化与血清学确认"},{"_id":"6a8369ecaf14b9c0e7b1ddfe","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Nawozy: - naturalne, - organiczne, w tym kompost, organiczno-mineralne, Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby, - stymulatory wzrostu, - podłoża do upraw","methodology":"Obecność żywych jaj pasożytów jelitowych Ascaris sp., Trichuris sp., Toxocara sp. w 100 g","parameters":[],"technique":"Metoda mikroskopowa","techniques":["Metoda mikroskopowa"],"computed":[],"activity":"Obecność żywych jaj pasożytów jelitowych Ascaris sp., Trichuris sp., Toxocara sp. w 100 g\nMetoda mikroskopowa","reference":"PB-DMP-77 wersja 01 z dnia 25.02.2021 r.","norm_bases":["PB-DMP-77 wersja 01 z dnia 25.02.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii","lab_address":null,"regulatory_area":"Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Nawozy: - naturalne, - organiczne, w tym kompost, organiczno-mineralne, Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby, - stymulatory wzrostu, - podłoża do upraw Obecność żywych jaj pasożytów jelitowych Ascaris sp., Trichuris sp., Toxocara sp. w 100 g\nMetoda mikroskopowa PB-DMP-77 wersja 01 z dnia 25.02.2021 r. Nawozy: - naturalne, - organiczne, w tym kompost, organiczno-mineralne, Srodki wspomagajace uprawe roslin: - srodki poprawiajace wlasciwosci gleby, - stymulatory wzrostu, - podloza do upraw Obecnosc zywych jaj pasozytow jelitowych Ascaris sp., Trichuris sp., Toxocara sp. w 100 g\nMetoda mikroskopowa PB-DMP-77 wersja 01 z dnia 25.02.2021 r.","categories":["other"],"row_index":476,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of live eggs of intestinal parasites Ascaris sp., Trichuris sp., Toxocara sp. in 100 g","search_en":"Fertilisers: - natural, - organic, including compost, organic-mineral, Plant cultivation aids: - soil improvers, - growth stimulants, - growing media Presence of live eggs of intestinal parasites Ascaris sp., Trichuris sp., Toxocara sp. in 100 g Microscopic method PB-DMP-77 wersja 01 z dnia 25.02.2021 r.","technique_en":"Microscopic method","test_object_en":"Fertilisers: - natural, - organic, including compost, organic-mineral, Plant cultivation aids: - soil improvers, - growth stimulants, - growing media","search_zh":"显微镜法 PB-DMP-77 wersja 01 z dnia 25.02.2021 r.","technique_zh":"显微镜法"},{"_id":"6a8369ecaf14b9c0e7b1ddff","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Próbki z systemów wentylacyjnych - wymaz","methodology":"Liczba drobnoustrojów w 30 °C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba drobnoustrojów w 30 °C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 4833-1: 2013-12+Ap1:2016-11","norm_bases":["PN-EN ISO 4833-1: 2013-12+Ap1:2016-11"],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii","lab_address":null,"regulatory_area":"Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Próbki z systemów wentylacyjnych - wymaz Liczba drobnoustrojów w 30 °C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 4833-1: 2013-12+Ap1:2016-11 Probki z systemow wentylacyjnych - wymaz Liczba drobnoustrojow w 30 °C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 4833-1: 2013-12+Ap1:2016-11","categories":["microbiology"],"row_index":477,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Count of microorganisms at 30 °C","search_en":"Samples from ventilation systems - swab Count of microorganisms at 30 °C Plate method (pour plate) PN-EN ISO 4833-1: 2013-12+Ap1:2016-11","technique_en":"Plate method (pour plate)","test_object_en":"Samples from ventilation systems - swab","search_zh":"平板法（倾注培养） PN-EN ISO 4833-1: 2013-12+Ap1:2016-11","technique_zh":"平板法（倾注培养）"},{"_id":"6a8369ecaf14b9c0e7b1de00","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Próbki z systemów wentylacyjnych - wymaz","methodology":"Liczba drożdży i pleśni","parameters":[],"technique":"Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda płytkowa (posiew powierzchniowy)"],"computed":[],"activity":"Liczba drożdży i pleśni\nMetoda płytkowa (posiew powierzchniowy)","reference":"PB-DMP-80 wersja 01 z dnia 25.02.2021 r.","norm_bases":["PB-DMP-80 wersja 01 z dnia 25.02.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii","lab_address":null,"regulatory_area":"Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Próbki z systemów wentylacyjnych - wymaz Liczba drożdży i pleśni\nMetoda płytkowa (posiew powierzchniowy) PB-DMP-80 wersja 01 z dnia 25.02.2021 r. Probki z systemow wentylacyjnych - wymaz Liczba drozdzy i plesni\nMetoda plytkowa (posiew powierzchniowy) PB-DMP-80 wersja 01 z dnia 25.02.2021 r.","categories":["other"],"row_index":478,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Yeast and mould count","search_en":"Samples from ventilation systems - swab Yeast and mould count Plate method (spread plate) PB-DMP-80 wersja 01 z dnia 25.02.2021 r.","technique_en":"Plate method (spread plate)","test_object_en":"Samples from ventilation systems - swab","methodology_zh":"酵母菌与霉菌计数","search_zh":"酵母菌与霉菌计数 平板法（表面涂布） PB-DMP-80 wersja 01 z dnia 25.02.2021 r.","technique_zh":"平板法（表面涂布）"},{"_id":"6a8369ecaf14b9c0e7b1de01","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Próbki z systemów wentylacyjnych - odcisk z powierzchni","methodology":"Liczba drobnoustrojów w 30 °C","parameters":[],"technique":"Metoda płytek kontaktowych","techniques":["Metoda płytek kontaktowych"],"computed":[],"activity":"Liczba drobnoustrojów w 30 °C\nMetoda płytek kontaktowych","reference":"PB-DMP-74 wersja 01 z dnia 25.02.2021 r.","norm_bases":["PB-DMP-74 wersja 01 z dnia 25.02.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Próbki z systemów wentylacyjnych - odcisk z powierzchni Liczba drobnoustrojów w 30 °C\nMetoda płytek kontaktowych PB-DMP-74 wersja 01 z dnia 25.02.2021 r. Probki z systemow wentylacyjnych - odcisk z powierzchni Liczba drobnoustrojow w 30 °C\nMetoda plytek kontaktowych PB-DMP-74 wersja 01 z dnia 25.02.2021 r.","categories":["microbiology"],"row_index":479,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Count of microorganisms at 30 °C","search_en":"Samples from ventilation systems - surface imprint Count of microorganisms at 30 °C Contact plate method PB-DMP-74 wersja 01 z dnia 25.02.2021 r.","technique_en":"Contact plate method","test_object_en":"Samples from ventilation systems - surface imprint","search_zh":"接触平皿法 PB-DMP-74 wersja 01 z dnia 25.02.2021 r.","technique_zh":"接触平皿法"},{"_id":"6a8369ecaf14b9c0e7b1de02","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Próbki z systemów wentylacyjnych - odcisk z powierzchni","methodology":"Liczba drożdży i pleśni","parameters":[],"technique":"Metoda płytek kontaktowych","techniques":["Metoda płytek kontaktowych"],"computed":[],"activity":"Liczba drożdży i pleśni\nMetoda płytek kontaktowych","reference":"PB-DMP-80 wersja 01 z dnia 25.02.2021 r.","norm_bases":["PB-DMP-80 wersja 01 z dnia 25.02.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Próbki z systemów wentylacyjnych - odcisk z powierzchni Liczba drożdży i pleśni\nMetoda płytek kontaktowych PB-DMP-80 wersja 01 z dnia 25.02.2021 r. Probki z systemow wentylacyjnych - odcisk z powierzchni Liczba drozdzy i plesni\nMetoda plytek kontaktowych PB-DMP-80 wersja 01 z dnia 25.02.2021 r.","categories":["other"],"row_index":480,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Yeast and mould count","search_en":"Samples from ventilation systems - surface imprint Yeast and mould count Contact plate method PB-DMP-80 wersja 01 z dnia 25.02.2021 r.","technique_en":"Contact plate method","test_object_en":"Samples from ventilation systems - surface imprint","methodology_zh":"酵母菌与霉菌计数","search_zh":"酵母菌与霉菌计数 接触平皿法 PB-DMP-80 wersja 01 z dnia 25.02.2021 r.","technique_zh":"接触平皿法"},{"_id":"6a8369ecaf14b9c0e7b1de03","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Powietrze","methodology":"Liczba bakterii w 30 °C","parameters":[],"technique":"Metoda płytkowa dla próbek pobranych metodą impakcji","techniques":["Metoda płytkowa dla próbek pobranych metodą impakcji"],"computed":[],"activity":"Liczba bakterii w 30 °C\nMetoda płytkowa dla próbek pobranych metodą impakcji","reference":"PN-EN 13098:2020-01 | PB-DMP-71 wersja 01 z dnia 25.02.2021 r.","norm_bases":["PN-EN 13098:2020-01","PB-DMP-71 wersja 01 z dnia 25.02.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Powietrze Liczba bakterii w 30 °C\nMetoda płytkowa dla próbek pobranych metodą impakcji PN-EN 13098:2020-01 | PB-DMP-71 wersja 01 z dnia 25.02.2021 r. Powietrze Liczba bakterii w 30 °C\nMetoda plytkowa dla probek pobranych metoda impakcji PN-EN 13098:2020-01 | PB-DMP-71 wersja 01 z dnia 25.02.2021 r.","categories":["environment","microbiology"],"row_index":481,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Bacteria count at 30 °C","search_en":"Air Bacteria count at 30 °C Plate method for samples collected by impaction PN-EN 13098:2020-01 | PB-DMP-71 wersja 01 z dnia 25.02.2021 r.","technique_en":"Plate method for samples collected by impaction","test_object_en":"Air","search_zh":"空气 PN-EN 13098:2020-01 | PB-DMP-71 wersja 01 z dnia 25.02.2021 r.","test_object_zh":"空气"},{"_id":"6a8369ecaf14b9c0e7b1de04","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Powietrze","methodology":"Liczba bakterii w 30 °C","parameters":[],"technique":"Metoda płytkowa dla próbek pobranych metodą filtracji","techniques":["Metoda płytkowa dla próbek pobranych metodą filtracji"],"computed":[],"activity":"Liczba bakterii w 30 °C\nMetoda płytkowa dla próbek pobranych metodą filtracji","reference":"PN-EN 13098:2020-01 | PB-DMP-71 wersja 01 z dnia 25.02.2021 r.","norm_bases":["PN-EN 13098:2020-01","PB-DMP-71 wersja 01 z dnia 25.02.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Powietrze Liczba bakterii w 30 °C\nMetoda płytkowa dla próbek pobranych metodą filtracji PN-EN 13098:2020-01 | PB-DMP-71 wersja 01 z dnia 25.02.2021 r. Powietrze Liczba bakterii w 30 °C\nMetoda plytkowa dla probek pobranych metoda filtracji PN-EN 13098:2020-01 | PB-DMP-71 wersja 01 z dnia 25.02.2021 r.","categories":["environment","microbiology"],"row_index":482,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Bacteria count at 30 °C","search_en":"Air Bacteria count at 30 °C Plate method for samples collected by filtration PN-EN 13098:2020-01 | PB-DMP-71 wersja 01 z dnia 25.02.2021 r.","technique_en":"Plate method for samples collected by filtration","test_object_en":"Air","search_zh":"空气 PN-EN 13098:2020-01 | PB-DMP-71 wersja 01 z dnia 25.02.2021 r.","test_object_zh":"空气"},{"_id":"6a8369ecaf14b9c0e7b1de05","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Powietrze","methodology":"Liczba grzybów, Ogólna liczba pleśni, Ogólna liczba drożdży","parameters":[],"technique":"Metoda płytkowa dla próbek pobranych metodą impakcji","techniques":["Metoda płytkowa dla próbek pobranych metodą impakcji"],"computed":[],"activity":"Liczba grzybów, Ogólna liczba pleśni, Ogólna liczba drożdży\nMetoda płytkowa dla próbek pobranych metodą impakcji","reference":"PN-EN 13098:2020-01 | PB-DMP-72 wersja 01 z dnia 25.02.2021 r.","norm_bases":["PN-EN 13098:2020-01","PB-DMP-72 wersja 01 z dnia 25.02.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Powietrze Liczba grzybów, Ogólna liczba pleśni, Ogólna liczba drożdży\nMetoda płytkowa dla próbek pobranych metodą impakcji PN-EN 13098:2020-01 | PB-DMP-72 wersja 01 z dnia 25.02.2021 r. Powietrze Liczba grzybow, Ogolna liczba plesni, Ogolna liczba drozdzy\nMetoda plytkowa dla probek pobranych metoda impakcji PN-EN 13098:2020-01 | PB-DMP-72 wersja 01 z dnia 25.02.2021 r.","categories":["environment","microbiology"],"row_index":483,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fungal count, Total mould count, Total yeast count","search_en":"Air Fungal count, Total mould count, Total yeast count Plate method for samples collected by impaction PN-EN 13098:2020-01 | PB-DMP-72 wersja 01 z dnia 25.02.2021 r.","technique_en":"Plate method for samples collected by impaction","test_object_en":"Air","search_zh":"空气 PN-EN 13098:2020-01 | PB-DMP-72 wersja 01 z dnia 25.02.2021 r.","test_object_zh":"空气"},{"_id":"6a8369ecaf14b9c0e7b1de06","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Powietrze","methodology":"Liczba grzybów","parameters":[],"technique":"Metoda płytkowa dla próbek pobranych metodą filtracji","techniques":["Metoda płytkowa dla próbek pobranych metodą filtracji"],"computed":[],"activity":"Liczba grzybów\nMetoda płytkowa dla próbek pobranych metodą filtracji","reference":"PN-EN 13098:2020-01 | PB-DMP-72 wersja 01 z dnia 25.02.2021 r.","norm_bases":["PN-EN 13098:2020-01","PB-DMP-72 wersja 01 z dnia 25.02.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Powietrze Liczba grzybów\nMetoda płytkowa dla próbek pobranych metodą filtracji PN-EN 13098:2020-01 | PB-DMP-72 wersja 01 z dnia 25.02.2021 r. Powietrze Liczba grzybow\nMetoda plytkowa dla probek pobranych metoda filtracji PN-EN 13098:2020-01 | PB-DMP-72 wersja 01 z dnia 25.02.2021 r.","categories":["environment","microbiology"],"row_index":484,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fungal count","search_en":"Air Fungal count Plate method for samples collected by filtration PN-EN 13098:2020-01 | PB-DMP-72 wersja 01 z dnia 25.02.2021 r.","technique_en":"Plate method for samples collected by filtration","test_object_en":"Air","search_zh":"空气 霉菌数 PN-EN 13098:2020-01 | PB-DMP-72 wersja 01 z dnia 25.02.2021 r.","test_object_zh":"空气","methodology_zh":"霉菌数"},{"_id":"6a8369ecaf14b9c0e7b1de07","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Szczep bakteryjny wyizolowany z: wody, gleby, powietrza, produktów przemysłowych oraz próbek środowiskowych","methodology":"Obecność i identyfikacja ziarniaków z rodzaju, Staphylococcus, Streptococcus, Micrococcus i Enterococcus","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność i identyfikacja ziarniaków z rodzaju, Staphylococcus, Streptococcus, Micrococcus i Enterococcus\nMetoda hodowlana z potwierdzeniem biochemicznym","reference":"PB-DMP-71-1 wersja 01 z dnia 25.02.2021 r.","norm_bases":["PB-DMP-71-1 wersja 01 z dnia 25.02.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Szczep bakteryjny wyizolowany z: wody, gleby, powietrza, produktów przemysłowych oraz próbek środowiskowych Obecność i identyfikacja ziarniaków z rodzaju, Staphylococcus, Streptococcus, Micrococcus i Enterococcus\nMetoda hodowlana z potwierdzeniem biochemicznym PB-DMP-71-1 wersja 01 z dnia 25.02.2021 r. Szczep bakteryjny wyizolowany z: wody, gleby, powietrza, produktow przemyslowych oraz probek srodowiskowych Obecnosc i identyfikacja ziarniakow z rodzaju, Staphylococcus, Streptococcus, Micrococcus i Enterococcus\nMetoda hodowlana z potwierdzeniem biochemicznym PB-DMP-71-1 wersja 01 z dnia 25.02.2021 r.","categories":["water","environment"],"row_index":485,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence and identification of cocci of the genus, Staphylococcus, Streptococcus, Micrococcus and Enterococcus","search_en":"Bacterial strain isolated from: water, soil, air, industrial products and environmental samples Presence and identification of cocci of the genus, Staphylococcus, Streptococcus, Micrococcus and Enterococcus Culture method with biochemical confirmation PB-DMP-71-1 wersja 01 z dnia 25.02.2021 r.","technique_en":"Culture method with biochemical confirmation","test_object_en":"Bacterial strain isolated from: water, soil, air, industrial products and environmental samples","search_zh":"培养法结合生化确认 PB-DMP-71-1 wersja 01 z dnia 25.02.2021 r.","technique_zh":"培养法结合生化确认"},{"_id":"6a8369ecaf14b9c0e7b1de08","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Szczep bakteryjny wyizolowany z: wody, gleby, powietrza, produktów przemysłowych oraz próbek środowiskowych","methodology":"Obecność i identyfikacja bakterii z rodzaju Bacillus","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność i identyfikacja bakterii z rodzaju Bacillus\nMetoda hodowlana z potwierdzeniem biochemicznym","reference":"PB-DMP-71-2 wersja 01 z dnia 25.02.2021 r.","norm_bases":["PB-DMP-71-2 wersja 01 z dnia 25.02.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Szczep bakteryjny wyizolowany z: wody, gleby, powietrza, produktów przemysłowych oraz próbek środowiskowych Obecność i identyfikacja bakterii z rodzaju Bacillus\nMetoda hodowlana z potwierdzeniem biochemicznym PB-DMP-71-2 wersja 01 z dnia 25.02.2021 r. Szczep bakteryjny wyizolowany z: wody, gleby, powietrza, produktow przemyslowych oraz probek srodowiskowych Obecnosc i identyfikacja bakterii z rodzaju Bacillus\nMetoda hodowlana z potwierdzeniem biochemicznym PB-DMP-71-2 wersja 01 z dnia 25.02.2021 r.","categories":["water","environment","microbiology"],"row_index":486,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence and identification of bacteria of the genus Bacillus","search_en":"Bacterial strain isolated from: water, soil, air, industrial products and environmental samples Presence and identification of bacteria of the genus Bacillus Culture method with biochemical confirmation PB-DMP-71-2 wersja 01 z dnia 25.02.2021 r.","technique_en":"Culture method with biochemical confirmation","test_object_en":"Bacterial strain isolated from: water, soil, air, industrial products and environmental samples","search_zh":"培养法结合生化确认 PB-DMP-71-2 wersja 01 z dnia 25.02.2021 r.","technique_zh":"培养法结合生化确认"},{"_id":"6a8369ecaf14b9c0e7b1de09","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Szczep bakteryjny wyizolowany z: wody, gleby, powietrza, produktów przemysłowych oraz próbek środowiskowych","methodology":"Obecność i identyfikacja kolonii bakterii z rodziny Enterobacteriaceae i pałeczek niefermentujących glukozy","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność i identyfikacja kolonii bakterii z rodziny Enterobacteriaceae i pałeczek niefermentujących glukozy\nMetoda hodowlana z potwierdzeniem biochemicznym","reference":"PB-DMP-71-3 wersja 01 z dnia 25.02.2021 r.","norm_bases":["PB-DMP-71-3 wersja 01 z dnia 25.02.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Szczep bakteryjny wyizolowany z: wody, gleby, powietrza, produktów przemysłowych oraz próbek środowiskowych Obecność i identyfikacja kolonii bakterii z rodziny Enterobacteriaceae i pałeczek niefermentujących glukozy\nMetoda hodowlana z potwierdzeniem biochemicznym PB-DMP-71-3 wersja 01 z dnia 25.02.2021 r. Szczep bakteryjny wyizolowany z: wody, gleby, powietrza, produktow przemyslowych oraz probek srodowiskowych Obecnosc i identyfikacja kolonii bakterii z rodziny Enterobacteriaceae i paleczek niefermentujacych glukozy\nMetoda hodowlana z potwierdzeniem biochemicznym PB-DMP-71-3 wersja 01 z dnia 25.02.2021 r.","categories":["water","environment","microbiology"],"row_index":487,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence and identification of colonies of bacteria of the family Enterobacteriaceae and of non-glucose-fermenting rods","search_en":"Bacterial strain isolated from: water, soil, air, industrial products and environmental samples Presence and identification of colonies of bacteria of the family Enterobacteriaceae and of non-glucose-fermenting rods Culture method with biochemical confirmation PB-DMP-71-3 wersja 01 z dnia 25.02.2021 r.","technique_en":"Culture method with biochemical confirmation","test_object_en":"Bacterial strain isolated from: water, soil, air, industrial products and environmental samples","search_zh":"培养法结合生化确认 PB-DMP-71-3 wersja 01 z dnia 25.02.2021 r.","technique_zh":"培养法结合生化确认"},{"_id":"6a8369ecaf14b9c0e7b1de0a","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w 22 °C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w 22 °C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 22 °C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda (w tym, woda na plywalniach), woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 22 °C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":488,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total viable count at 22 °C","search_en":"Water (including swimming pool water), water intended for human consumption Total viable count at 22 °C Plate method (pour plate) PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water (including swimming pool water), water intended for human consumption","methodology_zh":"22 °C 微生物总数","search_zh":"水（含游泳池水）、生活饮用水 22 °C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a8369ecaf14b9c0e7b1de0b","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w 36 °C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w 36 °C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 36 °C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda (w tym, woda na plywalniach), woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 36 °C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":489,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total viable count at 36 °C","search_en":"Water (including swimming pool water), water intended for human consumption Total viable count at 36 °C Plate method (pour plate) PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water (including swimming pool water), water intended for human consumption","methodology_zh":"36 °C 微生物总数","search_zh":"水（含游泳池水）、生活饮用水 36 °C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a8369ecaf14b9c0e7b1de0c","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi","methodology":"Liczba bakterii grupy coli, Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii grupy coli, Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi Liczba bakterii grupy coli, Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda (w tym, woda na plywalniach), woda do spozycia przez ludzi Liczba bakterii grupy coli, Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["microbiology","water"],"row_index":490,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Coliform bacteria count, Escherichia coli","search_en":"Water (including swimming pool water), water intended for human consumption Coliform bacteria count, Escherichia coli Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water (including swimming pool water), water intended for human consumption","search_zh":"水（含游泳池水）、生活饮用水 大肠菌群数、大肠埃希氏菌数 膜过滤法 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水（含游泳池水）、生活饮用水","methodology_zh":"大肠菌群数、大肠埃希氏菌数"},{"_id":"6a8369ecaf14b9c0e7b1de0d","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi","methodology":"Liczba enterokoków","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba enterokoków\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi Liczba enterokoków\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda (w tym, woda na plywalniach), woda do spozycia przez ludzi Liczba enterokokow\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":491,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Enterococci count","search_en":"Water (including swimming pool water), water intended for human consumption Enterococci count Membrane filtration method PN-EN ISO 7899-2:2004","technique_en":"Membrane filtration method","test_object_en":"Water (including swimming pool water), water intended for human consumption","methodology_zh":"肠球菌计数","search_zh":"水（含游泳池水）、生活饮用水 肠球菌计数 膜过滤法 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a8369ecaf14b9c0e7b1de0e","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi","methodology":"Liczba Pseudomonas aeruginosa","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009 Woda (w tym, woda na plywalniach), woda do spozycia przez ludzi Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water"],"row_index":492,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Pseudomonas aeruginosa count","search_en":"Water (including swimming pool water), water intended for human consumption Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009","technique_en":"Membrane filtration method","test_object_en":"Water (including swimming pool water), water intended for human consumption","methodology_zh":"铜绿假单胞菌计数","search_zh":"水（含游泳池水）、生活饮用水 铜绿假单胞菌计数 膜过滤法 PN-EN ISO 16266:2009","technique_zh":"膜过滤法","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a8369ecaf14b9c0e7b1de0f","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi","methodology":"Liczba Legionella sp.","parameters":[{"name":"Matryca A Procedura 5, 7 (pożywka A – BCYE, pożywka C – GVPC)"}],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Legionella sp.\nMatryca A Procedura 5, 7 (pożywka A – BCYE, pożywka C – GVPC)\nMetoda filtracji membranowej","reference":"PN-EN ISO 11731:2017-08","norm_bases":["PN-EN ISO 11731:2017-08"],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi Liczba Legionella sp.\nMatryca A Procedura 5, 7 (pożywka A – BCYE, pożywka C – GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 Woda (w tym, woda na plywalniach), woda do spozycia przez ludzi Liczba Legionella sp.\nMatryca A Procedura 5, 7 (pozywka A – BCYE, pozywka C – GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08","categories":["microbiology","water"],"row_index":493,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Legionella sp. count","parameters_en":[{"name":"Matrix A Procedure 5, 7 (medium A – BCYE, medium C – GVPC)"}],"search_en":"Water (including swimming pool water), water intended for human consumption Legionella sp. count Membrane filtration method Matrix A Procedure 5, 7 (medium A – BCYE, medium C – GVPC) PN-EN ISO 11731:2017-08","technique_en":"Membrane filtration method","test_object_en":"Water (including swimming pool water), water intended for human consumption","search_zh":"水（含游泳池水）、生活饮用水 军团菌属计数 膜过滤法 PN-EN ISO 11731:2017-08","technique_zh":"膜过滤法","test_object_zh":"水（含游泳池水）、生活饮用水","methodology_zh":"军团菌属计数"},{"_id":"6a8369ecaf14b9c0e7b1de10","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi","methodology":"Liczba Clostridium perfringens (łącznie ze sporami)","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Clostridium perfringens (łącznie ze sporami)\nMetoda filtracji membranowej","reference":"PN-EN ISO 14189:2016-10","norm_bases":["PN-EN ISO 14189:2016-10"],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi Liczba Clostridium perfringens (łącznie ze sporami)\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10 Woda (w tym, woda na plywalniach), woda do spozycia przez ludzi Liczba Clostridium perfringens (lacznie ze sporami)\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10","categories":["water"],"row_index":494,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Clostridium perfringens count (including spores)","search_en":"Water (including swimming pool water), water intended for human consumption Clostridium perfringens count (including spores) Membrane filtration method PN-EN ISO 14189:2016-10","technique_en":"Membrane filtration method","test_object_en":"Water (including swimming pool water), water intended for human consumption","search_zh":"水（含游泳池水）、生活饮用水 产气荚膜梭菌计数（含芽孢） 膜过滤法 PN-EN ISO 14189:2016-10","technique_zh":"膜过滤法","methodology_zh":"产气荚膜梭菌计数（含芽孢）","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a8369ecaf14b9c0e7b1de11","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi","methodology":"Liczba gronkowców koagulazo-dodatnich","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba gronkowców koagulazo-dodatnich\nMetoda filtracji membranowej","reference":"PB-DMP-75 wersja 01 z dnia 25.02.2021 r.","norm_bases":["PB-DMP-75 wersja 01 z dnia 25.02.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi Liczba gronkowców koagulazo-dodatnich\nMetoda filtracji membranowej PB-DMP-75 wersja 01 z dnia 25.02.2021 r. Woda (w tym, woda na plywalniach), woda do spozycia przez ludzi Liczba gronkowcow koagulazo-dodatnich\nMetoda filtracji membranowej PB-DMP-75 wersja 01 z dnia 25.02.2021 r.","categories":["water"],"row_index":495,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Coagulase-positive staphylococci count","search_en":"Water (including swimming pool water), water intended for human consumption Coagulase-positive staphylococci count Membrane filtration method PB-DMP-75 wersja 01 z dnia 25.02.2021 r.","technique_en":"Membrane filtration method","test_object_en":"Water (including swimming pool water), water intended for human consumption","search_zh":"水（含游泳池水）、生活饮用水 凝固酶阳性葡萄球菌计数 膜过滤法 PB-DMP-75 wersja 01 z dnia 25.02.2021 r.","technique_zh":"膜过滤法","methodology_zh":"凝固酶阳性葡萄球菌计数","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a8369ecaf14b9c0e7b1de12","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi","methodology":"Liczba Pseudomonas aeruginosa","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PB-DMP-79 wersja 01 z dnia 25.02.2021 r.","norm_bases":["PB-DMP-79 wersja 01 z dnia 25.02.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PB-DMP-79 wersja 01 z dnia 25.02.2021 r. Woda (w tym, woda na plywalniach), woda do spozycia przez ludzi Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PB-DMP-79 wersja 01 z dnia 25.02.2021 r.","categories":["water"],"row_index":496,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Pseudomonas aeruginosa count","search_en":"Water (including swimming pool water), water intended for human consumption Pseudomonas aeruginosa count Membrane filtration method PB-DMP-79 wersja 01 z dnia 25.02.2021 r.","technique_en":"Membrane filtration method","test_object_en":"Water (including swimming pool water), water intended for human consumption","methodology_zh":"铜绿假单胞菌计数","search_zh":"水（含游泳池水）、生活饮用水 铜绿假单胞菌计数 膜过滤法 PB-DMP-79 wersja 01 z dnia 25.02.2021 r.","technique_zh":"膜过滤法","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a8369ecaf14b9c0e7b1de13","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda","methodology":"Najbardziej prawdopodobna liczba bakterii grupy coli, Escherichia coli","parameters":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"computed":[],"activity":"Najbardziej prawdopodobna liczba bakterii grupy coli, Escherichia coli\nMetoda NPL","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Najbardziej prawdopodobna liczba bakterii grupy coli, Escherichia coli\nMetoda NPL PN-EN ISO 9308-2:2014-06 Woda Najbardziej prawdopodobna liczba bakterii grupy coli, Escherichia coli\nMetoda NPL PN-EN ISO 9308-2:2014-06","categories":["microbiology","water"],"row_index":497,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Most probable number of coliform bacteria, Escherichia coli","search_en":"Water Most probable number of coliform bacteria, Escherichia coli MPN method PN-EN ISO 9308-2:2014-06","technique_en":"MPN method","test_object_en":"Water","search_zh":"水 大肠菌群、大肠埃希氏菌最可能数 最可能数法（MPN） PN-EN ISO 9308-2:2014-06","technique_zh":"最可能数法（MPN）","test_object_zh":"水","methodology_zh":"大肠菌群、大肠埃希氏菌最可能数"},{"_id":"6a8369ecaf14b9c0e7b1de14","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda","methodology":"Najbardziej prawdopodobna liczba enterokoków","parameters":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"computed":[],"activity":"Najbardziej prawdopodobna liczba enterokoków\nMetoda NPL","reference":"PN-EN ISO 7899-3:2025-11","norm_bases":["PN-EN ISO 7899-3:2025-11"],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Najbardziej prawdopodobna liczba enterokoków\nMetoda NPL PN-EN ISO 7899-3:2025-11 Woda Najbardziej prawdopodobna liczba enterokokow\nMetoda NPL PN-EN ISO 7899-3:2025-11","categories":["water"],"row_index":498,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Most probable number of enterococci","search_en":"Water Most probable number of enterococci MPN method PN-EN ISO 7899-3:2025-11","technique_en":"MPN method","test_object_en":"Water","search_zh":"水 肠球菌最可能数 最可能数法（MPN） PN-EN ISO 7899-3:2025-11","technique_zh":"最可能数法（MPN）","test_object_zh":"水","methodology_zh":"肠球菌最可能数"},{"_id":"6a8369ecaf14b9c0e7b1de15","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w 36 °C po 24 h","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w 36 °C po 24 h\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 36 °C po 24 h\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda, Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 36 °C po 24 h\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":499,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Water, Water intended for human consumption Plate method (pour plate) PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water, Water intended for human consumption","search_zh":"水、生活饮用水 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水、生活饮用水"},{"_id":"6a8369ecaf14b9c0e7b1de16","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w 22 °C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w 22 °C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 22 °C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda (w tym, woda na plywalniach), woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 22 °C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":500,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total viable count at 22 °C","search_en":"Water (including swimming pool water), water intended for human consumption Total viable count at 22 °C Plate method (pour plate) PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water (including swimming pool water), water intended for human consumption","methodology_zh":"22 °C 微生物总数","search_zh":"水（含游泳池水）、生活饮用水 22 °C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a8369ecaf14b9c0e7b1de17","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w 36 °C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w 36 °C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 36 °C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda (w tym, woda na plywalniach), woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 36 °C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":501,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total viable count at 36 °C","search_en":"Water (including swimming pool water), water intended for human consumption Total viable count at 36 °C Plate method (pour plate) PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water (including swimming pool water), water intended for human consumption","methodology_zh":"36 °C 微生物总数","search_zh":"水（含游泳池水）、生活饮用水 36 °C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a8369ecaf14b9c0e7b1de18","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi","methodology":"Liczba bakterii grupy coli, Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii grupy coli, Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi Liczba bakterii grupy coli, Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda (w tym, woda na plywalniach), woda do spozycia przez ludzi Liczba bakterii grupy coli, Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["microbiology","water"],"row_index":502,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Coliform bacteria count, Escherichia coli","search_en":"Water (including swimming pool water), water intended for human consumption Coliform bacteria count, Escherichia coli Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water (including swimming pool water), water intended for human consumption","search_zh":"水（含游泳池水）、生活饮用水 大肠菌群数、大肠埃希氏菌数 膜过滤法 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水（含游泳池水）、生活饮用水","methodology_zh":"大肠菌群数、大肠埃希氏菌数"},{"_id":"6a8369ecaf14b9c0e7b1de19","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi","methodology":"Liczba enterokoków","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba enterokoków\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi Liczba enterokoków\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda (w tym, woda na plywalniach), woda do spozycia przez ludzi Liczba enterokokow\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":503,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Enterococci count","search_en":"Water (including swimming pool water), water intended for human consumption Enterococci count Membrane filtration method PN-EN ISO 7899-2:2004","technique_en":"Membrane filtration method","test_object_en":"Water (including swimming pool water), water intended for human consumption","methodology_zh":"肠球菌计数","search_zh":"水（含游泳池水）、生活饮用水 肠球菌计数 膜过滤法 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a8369ecaf14b9c0e7b1de1a","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi","methodology":"Liczba Pseudomonas aeruginosa","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009 Woda (w tym, woda na plywalniach), woda do spozycia przez ludzi Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water"],"row_index":504,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Pseudomonas aeruginosa count","search_en":"Water (including swimming pool water), water intended for human consumption Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009","technique_en":"Membrane filtration method","test_object_en":"Water (including swimming pool water), water intended for human consumption","methodology_zh":"铜绿假单胞菌计数","search_zh":"水（含游泳池水）、生活饮用水 铜绿假单胞菌计数 膜过滤法 PN-EN ISO 16266:2009","technique_zh":"膜过滤法","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a8369ecaf14b9c0e7b1de1b","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi","methodology":"Liczba Legionella sp.","parameters":[{"name":"Matryca A Procedura 5, 7 (pożywka A – BCYE, pożywka C – GVPC)"}],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Legionella sp.\nMatryca A Procedura 5, 7 (pożywka A – BCYE, pożywka C – GVPC)\nMetoda filtracji membranowej","reference":"PN-EN ISO 11731:2017-08","norm_bases":["PN-EN ISO 11731:2017-08"],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi Liczba Legionella sp.\nMatryca A Procedura 5, 7 (pożywka A – BCYE, pożywka C – GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 Woda (w tym, woda na plywalniach), woda do spozycia przez ludzi Liczba Legionella sp.\nMatryca A Procedura 5, 7 (pozywka A – BCYE, pozywka C – GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08","categories":["microbiology","water"],"row_index":505,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Legionella sp. count","parameters_en":[{"name":"Matrix A Procedure 5, 7 (medium A – BCYE, medium C – GVPC)"}],"search_en":"Water (including swimming pool water), water intended for human consumption Legionella sp. count Membrane filtration method Matrix A Procedure 5, 7 (medium A – BCYE, medium C – GVPC) PN-EN ISO 11731:2017-08","technique_en":"Membrane filtration method","test_object_en":"Water (including swimming pool water), water intended for human consumption","search_zh":"水（含游泳池水）、生活饮用水 军团菌属计数 膜过滤法 PN-EN ISO 11731:2017-08","technique_zh":"膜过滤法","test_object_zh":"水（含游泳池水）、生活饮用水","methodology_zh":"军团菌属计数"},{"_id":"6a8369ecaf14b9c0e7b1de1c","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi","methodology":"Liczba Clostridium perfringens (łącznie ze sporami)","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Clostridium perfringens (łącznie ze sporami)\nMetoda filtracji membranowej","reference":"PN-EN ISO 14189:2016-10","norm_bases":["PN-EN ISO 14189:2016-10"],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi Liczba Clostridium perfringens (łącznie ze sporami)\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10 Woda (w tym, woda na plywalniach), woda do spozycia przez ludzi Liczba Clostridium perfringens (lacznie ze sporami)\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10","categories":["water"],"row_index":506,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Clostridium perfringens count (including spores)","search_en":"Water (including swimming pool water), water intended for human consumption Clostridium perfringens count (including spores) Membrane filtration method PN-EN ISO 14189:2016-10","technique_en":"Membrane filtration method","test_object_en":"Water (including swimming pool water), water intended for human consumption","search_zh":"水（含游泳池水）、生活饮用水 产气荚膜梭菌计数（含芽孢） 膜过滤法 PN-EN ISO 14189:2016-10","technique_zh":"膜过滤法","methodology_zh":"产气荚膜梭菌计数（含芽孢）","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a8369ecaf14b9c0e7b1de1d","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi","methodology":"Liczba przetrwalników beztlenowców redukujących siarczyny (clostridia)","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba przetrwalników beztlenowców redukujących siarczyny (clostridia)\nMetoda filtracji membranowej","reference":"PN-EN 26461-2:2001","norm_bases":["PN-EN 26461-2:2001"],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi Liczba przetrwalników beztlenowców redukujących siarczyny (clostridia)\nMetoda filtracji membranowej PN-EN 26461-2:2001 Woda (w tym, woda na plywalniach), woda do spozycia przez ludzi Liczba przetrwalnikow beztlenowcow redukujacych siarczyny (clostridia)\nMetoda filtracji membranowej PN-EN 26461-2:2001","categories":["water"],"row_index":507,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Count of spores of sulphite-reducing anaerobes (clostridia)","search_en":"Water (including swimming pool water), water intended for human consumption Count of spores of sulphite-reducing anaerobes (clostridia) Membrane filtration method PN-EN 26461-2:2001","technique_en":"Membrane filtration method","test_object_en":"Water (including swimming pool water), water intended for human consumption","search_zh":"水（含游泳池水）、生活饮用水 亚硫酸盐还原厌氧菌（梭菌）芽孢计数 膜过滤法 PN-EN 26461-2:2001","technique_zh":"膜过滤法","test_object_zh":"水（含游泳池水）、生活饮用水","methodology_zh":"亚硫酸盐还原厌氧菌（梭菌）芽孢计数"},{"_id":"6a8369ecaf14b9c0e7b1de1e","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi","methodology":"Liczba gronkowców koagulazo-dodatnich","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba gronkowców koagulazo-dodatnich\nMetoda filtracji membranowej","reference":"PB-DMP-75 wersja 01 z dnia 25.02.2021 r.","norm_bases":["PB-DMP-75 wersja 01 z dnia 25.02.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi Liczba gronkowców koagulazo-dodatnich\nMetoda filtracji membranowej PB-DMP-75 wersja 01 z dnia 25.02.2021 r. Woda (w tym, woda na plywalniach), woda do spozycia przez ludzi Liczba gronkowcow koagulazo-dodatnich\nMetoda filtracji membranowej PB-DMP-75 wersja 01 z dnia 25.02.2021 r.","categories":["water"],"row_index":508,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Coagulase-positive staphylococci count","search_en":"Water (including swimming pool water), water intended for human consumption Coagulase-positive staphylococci count Membrane filtration method PB-DMP-75 wersja 01 z dnia 25.02.2021 r.","technique_en":"Membrane filtration method","test_object_en":"Water (including swimming pool water), water intended for human consumption","search_zh":"水（含游泳池水）、生活饮用水 凝固酶阳性葡萄球菌计数 膜过滤法 PB-DMP-75 wersja 01 z dnia 25.02.2021 r.","technique_zh":"膜过滤法","methodology_zh":"凝固酶阳性葡萄球菌计数","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a8369ecaf14b9c0e7b1de1f","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi","methodology":"Liczba Pseudomonas aeruginosa","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PB-DMP-79 wersja 01 z dnia 25.02.2021 r.","norm_bases":["PB-DMP-79 wersja 01 z dnia 25.02.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PB-DMP-79 wersja 01 z dnia 25.02.2021 r. Woda (w tym, woda na plywalniach), woda do spozycia przez ludzi Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PB-DMP-79 wersja 01 z dnia 25.02.2021 r.","categories":["water"],"row_index":509,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Pseudomonas aeruginosa count","search_en":"Water (including swimming pool water), water intended for human consumption Pseudomonas aeruginosa count Membrane filtration method PB-DMP-79 wersja 01 z dnia 25.02.2021 r.","technique_en":"Membrane filtration method","test_object_en":"Water (including swimming pool water), water intended for human consumption","methodology_zh":"铜绿假单胞菌计数","search_zh":"水（含游泳池水）、生活饮用水 铜绿假单胞菌计数 膜过滤法 PB-DMP-79 wersja 01 z dnia 25.02.2021 r.","technique_zh":"膜过滤法","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a8369ecaf14b9c0e7b1de20","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w 22 °C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w 22 °C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii; Wierzawice 874, 37-300 Leżajsk","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 22 °C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda (w tym, woda na plywalniach), woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 22 °C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":510,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total viable count at 22 °C","search_en":"Water (including swimming pool water), water intended for human consumption Total viable count at 22 °C Plate method (pour plate) PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water (including swimming pool water), water intended for human consumption","methodology_zh":"22 °C 微生物总数","search_zh":"水（含游泳池水）、生活饮用水 22 °C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a8369ecaf14b9c0e7b1de21","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w 36 °C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w 36 °C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii; Wierzawice 874, 37-300 Leżajsk","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 36 °C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda (w tym, woda na plywalniach), woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 36 °C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":511,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total viable count at 36 °C","search_en":"Water (including swimming pool water), water intended for human consumption Total viable count at 36 °C Plate method (pour plate) PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water (including swimming pool water), water intended for human consumption","methodology_zh":"36 °C 微生物总数","search_zh":"水（含游泳池水）、生活饮用水 36 °C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a8369ecaf14b9c0e7b1de22","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w 36 °C po 24 h","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w 36 °C po 24 h\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii; Wierzawice 874, 37-300 Leżajsk","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 36 °C po 24 h\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda (w tym, woda na plywalniach), woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 36 °C po 24 h\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":512,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Water (including swimming pool water), water intended for human consumption Plate method (pour plate) PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water (including swimming pool water), water intended for human consumption","search_zh":"水（含游泳池水）、生活饮用水 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a8369ecaf14b9c0e7b1de23","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi","methodology":"Liczba bakterii grupy coli, Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii grupy coli, Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii; Wierzawice 874, 37-300 Leżajsk","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi Liczba bakterii grupy coli, Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda (w tym, woda na plywalniach), woda do spozycia przez ludzi Liczba bakterii grupy coli, Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["microbiology","water"],"row_index":513,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Coliform bacteria count, Escherichia coli","search_en":"Water (including swimming pool water), water intended for human consumption Coliform bacteria count, Escherichia coli Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water (including swimming pool water), water intended for human consumption","search_zh":"水（含游泳池水）、生活饮用水 大肠菌群数、大肠埃希氏菌数 膜过滤法 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水（含游泳池水）、生活饮用水","methodology_zh":"大肠菌群数、大肠埃希氏菌数"},{"_id":"6a8369ecaf14b9c0e7b1de24","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi","methodology":"Liczba enterokoków kałowych","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba enterokoków kałowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii; Wierzawice 874, 37-300 Leżajsk","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi Liczba enterokoków kałowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda (w tym, woda na plywalniach), woda do spozycia przez ludzi Liczba enterokokow kalowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":514,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Intestinal enterococci count","search_en":"Water (including swimming pool water), water intended for human consumption Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004","technique_en":"Membrane filtration method","test_object_en":"Water (including swimming pool water), water intended for human consumption","methodology_zh":"粪肠球菌计数","search_zh":"水（含游泳池水）、生活饮用水 粪肠球菌计数 膜过滤法 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a8369ecaf14b9c0e7b1de25","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi","methodology":"Liczba Pseudomonas aeruginosa","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii; Wierzawice 874, 37-300 Leżajsk","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009 Woda (w tym, woda na plywalniach), woda do spozycia przez ludzi Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water"],"row_index":515,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Pseudomonas aeruginosa count","search_en":"Water (including swimming pool water), water intended for human consumption Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009","technique_en":"Membrane filtration method","test_object_en":"Water (including swimming pool water), water intended for human consumption","methodology_zh":"铜绿假单胞菌计数","search_zh":"水（含游泳池水）、生活饮用水 铜绿假单胞菌计数 膜过滤法 PN-EN ISO 16266:2009","technique_zh":"膜过滤法","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a8369ecaf14b9c0e7b1de26","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi","methodology":"Liczba Legionella sp., Matryca A, Procedura 5, 7 (pożywka A – BYCE, pożywka C – GVPC)","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Legionella sp., Matryca A, Procedura 5, 7 (pożywka A – BYCE, pożywka C – GVPC)\nMetoda filtracji membranowej","reference":"PN-EN ISO 11731:2017-08","norm_bases":["PN-EN ISO 11731:2017-08"],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii; Wierzawice 874, 37-300 Leżajsk","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi Liczba Legionella sp., Matryca A, Procedura 5, 7 (pożywka A – BYCE, pożywka C – GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 Woda (w tym, woda na plywalniach), woda do spozycia przez ludzi Liczba Legionella sp., Matryca A, Procedura 5, 7 (pozywka A – BYCE, pozywka C – GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08","categories":["microbiology","water"],"row_index":516,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Legionella sp. count, Matrix A, Procedure 5, 7 (medium A – BYCE, medium C – GVPC)","search_en":"Water (including swimming pool water), water intended for human consumption Legionella sp. count, Matrix A, Procedure 5, 7 (medium A – BYCE, medium C – GVPC) Membrane filtration method PN-EN ISO 11731:2017-08","technique_en":"Membrane filtration method","test_object_en":"Water (including swimming pool water), water intended for human consumption","search_zh":"水（含游泳池水）、生活饮用水 膜过滤法 PN-EN ISO 11731:2017-08","technique_zh":"膜过滤法","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a8369ecaf14b9c0e7b1de27","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi","methodology":"Liczba Clostridium perfringens (łącznie ze sporami)","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Clostridium perfringens (łącznie ze sporami)\nMetoda filtracji membranowej","reference":"PN-EN ISO 14189:2016-10","norm_bases":["PN-EN ISO 14189:2016-10"],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii; Wierzawice 874, 37-300 Leżajsk","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi Liczba Clostridium perfringens (łącznie ze sporami)\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10 Woda (w tym, woda na plywalniach), woda do spozycia przez ludzi Liczba Clostridium perfringens (lacznie ze sporami)\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10","categories":["water"],"row_index":517,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Clostridium perfringens count (including spores)","search_en":"Water (including swimming pool water), water intended for human consumption Clostridium perfringens count (including spores) Membrane filtration method PN-EN ISO 14189:2016-10","technique_en":"Membrane filtration method","test_object_en":"Water (including swimming pool water), water intended for human consumption","search_zh":"水（含游泳池水）、生活饮用水 产气荚膜梭菌计数（含芽孢） 膜过滤法 PN-EN ISO 14189:2016-10","technique_zh":"膜过滤法","methodology_zh":"产气荚膜梭菌计数（含芽孢）","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a8369ecaf14b9c0e7b1de28","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi","methodology":"Liczba gronkowców koagulazo-dodatnich","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba gronkowców koagulazo-dodatnich\nMetoda filtracji membranowej","reference":"PB-DMP-75 wersja 01 z dnia 25.02.2021 r.","norm_bases":["PB-DMP-75 wersja 01 z dnia 25.02.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii; Wierzawice 874, 37-300 Leżajsk","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi Liczba gronkowców koagulazo-dodatnich\nMetoda filtracji membranowej PB-DMP-75 wersja 01 z dnia 25.02.2021 r. Woda (w tym, woda na plywalniach), woda do spozycia przez ludzi Liczba gronkowcow koagulazo-dodatnich\nMetoda filtracji membranowej PB-DMP-75 wersja 01 z dnia 25.02.2021 r.","categories":["water"],"row_index":518,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Coagulase-positive staphylococci count","search_en":"Water (including swimming pool water), water intended for human consumption Coagulase-positive staphylococci count Membrane filtration method PB-DMP-75 wersja 01 z dnia 25.02.2021 r.","technique_en":"Membrane filtration method","test_object_en":"Water (including swimming pool water), water intended for human consumption","search_zh":"水（含游泳池水）、生活饮用水 凝固酶阳性葡萄球菌计数 膜过滤法 PB-DMP-75 wersja 01 z dnia 25.02.2021 r.","technique_zh":"膜过滤法","methodology_zh":"凝固酶阳性葡萄球菌计数","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a8369ecaf14b9c0e7b1de29","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi","methodology":"Liczba Pseudomonas aeruginosa","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PB-DMP-79 wersja 01 z dnia 25.02.2021 r.","norm_bases":["PB-DMP-79 wersja 01 z dnia 25.02.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Mikrobiologii i Parazytologii; Wierzawice 874, 37-300 Leżajsk","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym, woda na pływalniach), woda do spożycia przez ludzi Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PB-DMP-79 wersja 01 z dnia 25.02.2021 r. Woda (w tym, woda na plywalniach), woda do spozycia przez ludzi Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PB-DMP-79 wersja 01 z dnia 25.02.2021 r.","categories":["water"],"row_index":519,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Pseudomonas aeruginosa count","search_en":"Water (including swimming pool water), water intended for human consumption Pseudomonas aeruginosa count Membrane filtration method PB-DMP-79 wersja 01 z dnia 25.02.2021 r.","technique_en":"Membrane filtration method","test_object_en":"Water (including swimming pool water), water intended for human consumption","methodology_zh":"铜绿假单胞菌计数","search_zh":"水（含游泳池水）、生活饮用水 铜绿假单胞菌计数 膜过滤法 PB-DMP-79 wersja 01 z dnia 25.02.2021 r.","technique_zh":"膜过滤法","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a8369ecaf14b9c0e7b1de2a","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie pestycydów chloroorganicznych","parameters":[{"name":"alfa-HCH","range":"(0,020 - 5,00) μg/l"},{"name":"beta-HCH","range":"(0,020 5,00) μg/l"},{"name":"gamma-HCH","range":"(0,020 - 5,00) μg/l"},{"name":"delta-HCH","range":"(0,020 - 5,00) μg/l"},{"name":"Zakres","range":"2,4'-DDD (0,020 - 5,00) μg/l"},{"name":"2,4'-DDE","range":"(0,020 - 5,00) μg/l"},{"name":"2,4‘-DDT","range":"(0,020 - 5,00) μg/l"},{"name":"4,4‘-DDD","range":"(0,020 - 5,00) μg/l"},{"name":"4,4'-DDE","range":"(0,020 - 5,00) μg/l"},{"name":"4,4'-DDT","range":"(0,020 - 5,00) μg/l"},{"name":"aldryna","range":"(0,020 - 5,00) μg/l"},{"name":"dieldryna","range":"(0,020 - 5,00) μg/l"},{"name":"endryna","range":"(0,020 - 5,00) μg/l"},{"name":"aldehyd endryny","range":"(0,020 - 5,00) μg/l"},{"name":"izodryna","range":"(0,020 - 5,00) μg/l"},{"name":"heptachlor","range":"(0,020 - 5,00) μg/l"},{"name":"epoksyd heptachloru","range":"(0,020 - 5,00) μg/l"},{"name":"cis-chlordan","range":"(0,020 - 5,00) μg/l"},{"name":"trans-chlordan","range":"(0,020 - 5,00) μg/l"},{"name":"metoksychlor","range":"(0,020 - 5,00) μg/l"},{"name":"endosulfan I","range":"(0,020 - 5,00) μg/l"},{"name":"endosulfan II","range":"(0,020 - 5,00) μg/l"},{"name":"siarczan endosulfanu","range":"(0,020 - 5,00) μg/l"},{"name":"1,2,3-trichlorobenzen","range":"(0,20 - 200) μg/l"},{"name":"1,2,4-trichlorobenzen","range":"(0,20 - 200) μg/l"},{"name":"1,3,5-trchlorobenzen","range":"(0,20 - 200) μg/l"},{"name":"1,2,3,4-tetrachlorobenzen","range":"(0,020 - 5,00) μg/l"},{"name":"(1,2,3,5+1,2,4,5)-tetrachlorobenzen","range":"(0,040 - 10,00) μg/l"},{"name":"pentachlorobenzen","range":"(0,020 - 5,00) μg/l"},{"name":"heksachlorobenzen","range":"(0,020 - 5,00) μg/l"}],"technique":"Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","techniques":["Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)"],"computed":[],"activity":"Stężenie pestycydów chloroorganicznych\nZakres:\nalfa-HCH (0,020 - 5,00) μg/l\nbeta-HCH (0,020 5,00) μg/l\ngamma-HCH (0,020 - 5,00) μg/l\ndelta-HCH (0,020 - 5,00) μg/l\nZakres 2,4'-DDD (0,020 - 5,00) μg/l\n2,4'-DDE (0,020 - 5,00) μg/l\n2,4‘-DDT (0,020 - 5,00) μg/l\n4,4‘-DDD (0,020 - 5,00) μg/l\n4,4'-DDE (0,020 - 5,00) μg/l\n4,4'-DDT (0,020 - 5,00) μg/l\naldryna (0,020 - 5,00) μg/l\ndieldryna (0,020 - 5,00) μg/l\nendryna (0,020 - 5,00) μg/l\naldehyd endryny (0,020 - 5,00) μg/l\nizodryna (0,020 - 5,00) μg/l\nheptachlor (0,020 - 5,00) μg/l\nepoksyd heptachloru (0,020 - 5,00) μg/l\ncis-chlordan (0,020 - 5,00) μg/l\ntrans-chlordan (0,020 - 5,00) μg/l\nmetoksychlor (0,020 - 5,00) μg/l\nendosulfan I (0,020 - 5,00) μg/l\nendosulfan II (0,020 - 5,00) μg/l\nsiarczan endosulfanu (0,020 - 5,00) μg/l\n1,2,3-trichlorobenzen (0,20 - 200) μg/l\n1,2,4-trichlorobenzen (0,20 - 200) μg/l\n1,3,5-trchlorobenzen (0,20 - 200) μg/l\n1,2,3,4-tetrachlorobenzen (0,020 - 5,00) μg/l\n(1,2,3,5+1,2,4,5)-tetrachlorobenzen (0,040 - 10,00) μg/l\npentachlorobenzen (0,020 - 5,00) μg/l\nheksachlorobenzen (0,020 - 5,00) μg/l\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","reference":"PN-EN ISO 6468:2002","norm_bases":["PN-EN ISO 6468:2002"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Organicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie pestycydów chloroorganicznych\nZakres:\nalfa-HCH (0,020 - 5,00) μg/l\nbeta-HCH (0,020 5,00) μg/l\ngamma-HCH (0,020 - 5,00) μg/l\ndelta-HCH (0,020 - 5,00) μg/l\nZakres 2,4'-DDD (0,020 - 5,00) μg/l\n2,4'-DDE (0,020 - 5,00) μg/l\n2,4‘-DDT (0,020 - 5,00) μg/l\n4,4‘-DDD (0,020 - 5,00) μg/l\n4,4'-DDE (0,020 - 5,00) μg/l\n4,4'-DDT (0,020 - 5,00) μg/l\naldryna (0,020 - 5,00) μg/l\ndieldryna (0,020 - 5,00) μg/l\nendryna (0,020 - 5,00) μg/l\naldehyd endryny (0,020 - 5,00) μg/l\nizodryna (0,020 - 5,00) μg/l\nheptachlor (0,020 - 5,00) μg/l\nepoksyd heptachloru (0,020 - 5,00) μg/l\ncis-chlordan (0,020 - 5,00) μg/l\ntrans-chlordan (0,020 - 5,00) μg/l\nmetoksychlor (0,020 - 5,00) μg/l\nendosulfan I (0,020 - 5,00) μg/l\nendosulfan II (0,020 - 5,00) μg/l\nsiarczan endosulfanu (0,020 - 5,00) μg/l\n1,2,3-trichlorobenzen (0,20 - 200) μg/l\n1,2,4-trichlorobenzen (0,20 - 200) μg/l\n1,3,5-trchlorobenzen (0,20 - 200) μg/l\n1,2,3,4-tetrachlorobenzen (0,020 - 5,00) μg/l\n(1,2,3,5+1,2,4,5)-tetrachlorobenzen (0,040 - 10,00) μg/l\npentachlorobenzen (0,020 - 5,00) μg/l\nheksachlorobenzen (0,020 - 5,00) μg/l\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) PN-EN ISO 6468:2002 Woda, Scieki Stezenie pestycydow chloroorganicznych\nZakres:\nalfa-HCH (0,020 - 5,00) μg/l\nbeta-HCH (0,020 5,00) μg/l\ngamma-HCH (0,020 - 5,00) μg/l\ndelta-HCH (0,020 - 5,00) μg/l\nZakres 2,4'-DDD (0,020 - 5,00) μg/l\n2,4'-DDE (0,020 - 5,00) μg/l\n2,4‘-DDT (0,020 - 5,00) μg/l\n4,4‘-DDD (0,020 - 5,00) μg/l\n4,4'-DDE (0,020 - 5,00) μg/l\n4,4'-DDT (0,020 - 5,00) μg/l\naldryna (0,020 - 5,00) μg/l\ndieldryna (0,020 - 5,00) μg/l\nendryna (0,020 - 5,00) μg/l\naldehyd endryny (0,020 - 5,00) μg/l\nizodryna (0,020 - 5,00) μg/l\nheptachlor (0,020 - 5,00) μg/l\nepoksyd heptachloru (0,020 - 5,00) μg/l\ncis-chlordan (0,020 - 5,00) μg/l\ntrans-chlordan (0,020 - 5,00) μg/l\nmetoksychlor (0,020 - 5,00) μg/l\nendosulfan I (0,020 - 5,00) μg/l\nendosulfan II (0,020 - 5,00) μg/l\nsiarczan endosulfanu (0,020 - 5,00) μg/l\n1,2,3-trichlorobenzen (0,20 - 200) μg/l\n1,2,4-trichlorobenzen (0,20 - 200) μg/l\n1,3,5-trchlorobenzen (0,20 - 200) μg/l\n1,2,3,4-tetrachlorobenzen (0,020 - 5,00) μg/l\n(1,2,3,5+1,2,4,5)-tetrachlorobenzen (0,040 - 10,00) μg/l\npentachlorobenzen (0,020 - 5,00) μg/l\nheksachlorobenzen (0,020 - 5,00) μg/l\nMetoda chromatografii gazowej z detekcja wychwytu elektronow (GC-ECD) PN-EN ISO 6468:2002","categories":["water"],"row_index":520,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Organochlorine pesticide concentration","parameters_en":[{"name":"alpha-HCH","range":"(0,020 - 5,00) μg/l"},{"name":"beta-HCH","range":"(0,020 5,00) μg/l"},{"name":"gamma-HCH","range":"(0,020 - 5,00) μg/l"},{"name":"delta-HCH","range":"(0,020 - 5,00) μg/l"},{"name":"Range","range":"2,4'-DDD (0,020 - 5,00) μg/l"},{"name":"2,4'-DDE","range":"(0,020 - 5,00) μg/l"},{"name":"2,4‘-DDT","range":"(0,020 - 5,00) μg/l"},{"name":"4,4‘-DDD","range":"(0,020 - 5,00) μg/l"},{"name":"4,4'-DDE","range":"(0,020 - 5,00) μg/l"},{"name":"4,4'-DDT","range":"(0,020 - 5,00) μg/l"},{"name":"aldrin","range":"(0,020 - 5,00) μg/l"},{"name":"dieldrin","range":"(0,020 - 5,00) μg/l"},{"name":"endrin","range":"(0,020 - 5,00) μg/l"},{"name":"endrin aldehyde","range":"(0,020 - 5,00) μg/l"},{"name":"isodrin","range":"(0,020 - 5,00) μg/l"},{"name":"heptachlor","range":"(0,020 - 5,00) μg/l"},{"name":"heptachlor epoxide","range":"(0,020 - 5,00) μg/l"},{"name":"cis-chlordane","range":"(0,020 - 5,00) μg/l"},{"name":"trans-chlordane","range":"(0,020 - 5,00) μg/l"},{"name":"methoxychlor","range":"(0,020 - 5,00) μg/l"},{"name":"endosulfan I","range":"(0,020 - 5,00) μg/l"},{"name":"endosulfan II","range":"(0,020 - 5,00) μg/l"},{"name":"endosulfan sulfate","range":"(0,020 - 5,00) μg/l"},{"name":"1,2,3-trichlorobenzene","range":"(0,20 - 200) μg/l"},{"name":"1,2,4-trichlorobenzene","range":"(0,20 - 200) μg/l"},{"name":"1,3,5-trchlorobenzene","range":"(0,20 - 200) μg/l"},{"name":"1,2,3,4-tetrachlorobenzene","range":"(0,020 - 5,00) μg/l"},{"name":"(1,2,3,5+1,2,4,5)-tetrachlorobenzene","range":"(0,040 - 10,00) μg/l"},{"name":"pentachlorobenzene","range":"(0,020 - 5,00) μg/l"},{"name":"hexachlorobenzene","range":"(0,020 - 5,00) μg/l"}],"search_en":"Water, Wastewater Organochlorine pesticide concentration Gas chromatography with electron capture detection (GC-ECD) alpha-HCH beta-HCH gamma-HCH delta-HCH Range 2,4'-DDE 2,4‘-DDT 4,4‘-DDD 4,4'-DDE 4,4'-DDT aldrin dieldrin endrin endrin aldehyde isodrin heptachlor heptachlor epoxide cis-chlordane trans-chlordane methoxychlor endosulfan I endosulfan II endosulfan sulfate 1,2,3-trichlorobenzene 1,2,4-trichlorobenzene 1,3,5-trchlorobenzene 1,2,3,4-tetrachlorobenzene (1,2,3,5+1,2,4,5)-tetrachlorobenzene pentachlorobenzene hexachlorobenzene PN-EN ISO 6468:2002","technique_en":"Gas chromatography with electron capture detection (GC-ECD)","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"α-六六六","range":"(0,020 - 5,00) μg/l"},{"name":"β-六六六","range":"(0,020 5,00) μg/l"},{"name":"gamma-HCH","range":"(0,020 - 5,00) μg/l"},{"name":"δ-六六六","range":"(0,020 - 5,00) μg/l"},{"name":"范围","range":"2,4'-DDD (0,020 - 5,00) μg/l"},{"name":"2,4'-DDE","range":"(0,020 - 5,00) μg/l"},{"name":"2,4‘-DDT","range":"(0,020 - 5,00) μg/l"},{"name":"4,4‘-DDD","range":"(0,020 - 5,00) μg/l"},{"name":"4,4'-DDE","range":"(0,020 - 5,00) μg/l"},{"name":"4,4'-DDT","range":"(0,020 - 5,00) μg/l"},{"name":"艾氏剂","range":"(0,020 - 5,00) μg/l"},{"name":"狄氏剂","range":"(0,020 - 5,00) μg/l"},{"name":"异狄氏剂","range":"(0,020 - 5,00) μg/l"},{"name":"异狄氏剂醛","range":"(0,020 - 5,00) μg/l"},{"name":"异艾氏剂","range":"(0,020 - 5,00) μg/l"},{"name":"七氯","range":"(0,020 - 5,00) μg/l"},{"name":"环氧七氯","range":"(0,020 - 5,00) μg/l"},{"name":"cis-chlordan","range":"(0,020 - 5,00) μg/l"},{"name":"trans-chlordan","range":"(0,020 - 5,00) μg/l"},{"name":"甲氧滴滴涕","range":"(0,020 - 5,00) μg/l"},{"name":"硫丹 I","range":"(0,020 - 5,00) μg/l"},{"name":"硫丹 II","range":"(0,020 - 5,00) μg/l"},{"name":"siarczan endosulfanu","range":"(0,020 - 5,00) μg/l"},{"name":"1,2,3-三氯苯","range":"(0,20 - 200) μg/l"},{"name":"1,2,4-三氯苯","range":"(0,20 - 200) μg/l"},{"name":"1,3,5-trchlorobenzen","range":"(0,20 - 200) μg/l"},{"name":"1,2,3,4-四氯苯","range":"(0,020 - 5,00) μg/l"},{"name":"(1,2,3,5+1,2,4,5)-tetrachlorobenzen","range":"(0,040 - 10,00) μg/l"},{"name":"五氯苯","range":"(0,020 - 5,00) μg/l"},{"name":"六氯苯","range":"(0,020 - 5,00) μg/l"}],"search_zh":"水、污水 有机氯农药浓度 气相色谱-电子捕获检测法（GC-ECD） α-六六六 β-六六六 δ-六六六 范围 艾氏剂 狄氏剂 异狄氏剂 异狄氏剂醛 异艾氏剂 七氯 环氧七氯 甲氧滴滴涕 硫丹 I 硫丹 II 1,2,3-三氯苯 1,2,4-三氯苯 1,2,3,4-四氯苯 五氯苯 六氯苯 PN-EN ISO 6468:2002","technique_zh":"气相色谱-电子捕获检测法（GC-ECD）","test_object_zh":"水、污水","methodology_zh":"有机氯农药浓度"},{"_id":"6a8369ecaf14b9c0e7b1de2b","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie chlorofenoli","parameters":[{"name":"Zakres","range":"2,4,6-trichlorofenol (0,4 - 100) μg/l"},{"name":"pentachlorofenol","range":"(0,4 – 100) μg/l"}],"technique":"Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","techniques":["Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)"],"computed":[],"activity":"Stężenie chlorofenoli\nZakres:\nZakres 2,4,6-trichlorofenol (0,4 - 100) μg/l\npentachlorofenol (0,4 – 100) μg/l\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","reference":"PN-EN 12673:2004","norm_bases":["PN-EN 12673:2004"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Organicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie chlorofenoli\nZakres:\nZakres 2,4,6-trichlorofenol (0,4 - 100) μg/l\npentachlorofenol (0,4 – 100) μg/l\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) PN-EN 12673:2004 Woda, Scieki Stezenie chlorofenoli\nZakres:\nZakres 2,4,6-trichlorofenol (0,4 - 100) μg/l\npentachlorofenol (0,4 – 100) μg/l\nMetoda chromatografii gazowej z detekcja wychwytu elektronow (GC-ECD) PN-EN 12673:2004","categories":["water"],"row_index":521,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chlorophenol concentration","parameters_en":[{"name":"Range","range":"2,4,6-trichlorofenol (0,4 - 100) μg/l"},{"name":"pentachlorophenol","range":"(0,4 – 100) μg/l"}],"search_en":"Water, Wastewater Chlorophenol concentration Gas chromatography with electron capture detection (GC-ECD) Range pentachlorophenol PN-EN 12673:2004","technique_en":"Gas chromatography with electron capture detection (GC-ECD)","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"2,4,6-trichlorofenol (0,4 - 100) μg/l"},{"name":"pentachlorofenol","range":"(0,4 – 100) μg/l"}],"search_zh":"水、污水 气相色谱-电子捕获检测法（GC-ECD） 范围 PN-EN 12673:2004","technique_zh":"气相色谱-电子捕获检测法（GC-ECD）","test_object_zh":"水、污水"},{"_id":"6a8369ecaf14b9c0e7b1de2c","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie polichlorowanych bifenyli (PCB)","parameters":[{"name":"PCB 28","range":"(0,050 - 2,0) μg/l"},{"name":"PCB 52","range":"(0,050 - 2,0) μg/l"},{"name":"PCB 101","range":"(0,050 - 2,0) μg/l"},{"name":"PCB 118","range":"(0,050 - 2,0) μg/l"},{"name":"PCB 138","range":"(0,050 - 2,0) μg/l"},{"name":"PCB 153","range":"(0,050 - 2,0) μg/l"},{"name":"PCB 180","range":"(0,050 - 2,0) μg/l"}],"technique":"Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","techniques":["Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)"],"computed":[],"activity":"Stężenie polichlorowanych bifenyli (PCB)\nZakres:\nPCB 28 (0,050 - 2,0) μg/l\nPCB 52 (0,050 - 2,0) μg/l\nPCB 101 (0,050 - 2,0) μg/l\nPCB 118 (0,050 - 2,0) μg/l\nPCB 138 (0,050 - 2,0) μg/l\nPCB 153 (0,050 - 2,0) μg/l\nPCB 180 (0,050 - 2,0) μg/l\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","reference":"PN-EN ISO 6468:2002","norm_bases":["PN-EN ISO 6468:2002"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Organicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie polichlorowanych bifenyli (PCB)\nZakres:\nPCB 28 (0,050 - 2,0) μg/l\nPCB 52 (0,050 - 2,0) μg/l\nPCB 101 (0,050 - 2,0) μg/l\nPCB 118 (0,050 - 2,0) μg/l\nPCB 138 (0,050 - 2,0) μg/l\nPCB 153 (0,050 - 2,0) μg/l\nPCB 180 (0,050 - 2,0) μg/l\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) PN-EN ISO 6468:2002 Woda, Scieki Stezenie polichlorowanych bifenyli (PCB)\nZakres:\nPCB 28 (0,050 - 2,0) μg/l\nPCB 52 (0,050 - 2,0) μg/l\nPCB 101 (0,050 - 2,0) μg/l\nPCB 118 (0,050 - 2,0) μg/l\nPCB 138 (0,050 - 2,0) μg/l\nPCB 153 (0,050 - 2,0) μg/l\nPCB 180 (0,050 - 2,0) μg/l\nMetoda chromatografii gazowej z detekcja wychwytu elektronow (GC-ECD) PN-EN ISO 6468:2002","categories":["water"],"row_index":522,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Polychlorinated biphenyls (PCB) concentration","parameters_en":[{"name":"PCB 28","range":"(0,050 - 2,0) μg/l"},{"name":"PCB 52","range":"(0,050 - 2,0) μg/l"},{"name":"PCB 101","range":"(0,050 - 2,0) μg/l"},{"name":"PCB 118","range":"(0,050 - 2,0) μg/l"},{"name":"PCB 138","range":"(0,050 - 2,0) μg/l"},{"name":"PCB 153","range":"(0,050 - 2,0) μg/l"},{"name":"PCB 180","range":"(0,050 - 2,0) μg/l"}],"search_en":"Water, Wastewater Polychlorinated biphenyls (PCB) concentration Gas chromatography with electron capture detection (GC-ECD) PCB 28 PCB 52 PCB 101 PCB 118 PCB 138 PCB 153 PCB 180 PN-EN ISO 6468:2002","technique_en":"Gas chromatography with electron capture detection (GC-ECD)","test_object_en":"Water, Wastewater","search_zh":"水、污水 多氯联苯（PCB）浓度 气相色谱-电子捕获检测法（GC-ECD） PCB 28 PCB 52 PCB 101 PCB 118 PCB 138 PCB 153 PCB 180 PN-EN ISO 6468:2002","technique_zh":"气相色谱-电子捕获检测法（GC-ECD）","test_object_zh":"水、污水","parameters_zh":[{"name":"PCB 28","range":"(0,050 - 2,0) μg/l"},{"name":"PCB 52","range":"(0,050 - 2,0) μg/l"},{"name":"PCB 101","range":"(0,050 - 2,0) μg/l"},{"name":"PCB 118","range":"(0,050 - 2,0) μg/l"},{"name":"PCB 138","range":"(0,050 - 2,0) μg/l"},{"name":"PCB 153","range":"(0,050 - 2,0) μg/l"},{"name":"PCB 180","range":"(0,050 - 2,0) μg/l"}],"methodology_zh":"多氯联苯（PCB）浓度"},{"_id":"6a8369ecaf14b9c0e7b1de2d","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)","parameters":[{"name":"benzo(a)piren","range":"(0,006 - 2,00) μg/l"},{"name":"benzo(b)fluoranten","range":"(0,006 - 2,00) μg/l"},{"name":"benzo(ghi)perylen","range":"(0,006 - 2,00) μg/l"},{"name":"benzo(k)fluoranten","range":"(0,006 - 2,00) μg/l"},{"name":"dibenzo(ah)antracen","range":"(0,006 - 2,00) μg/l"},{"name":"indeno(1,2,3-cd)piren","range":"(0,006 - 2,00) μg/l"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)\nZakres:\nbenzo(a)piren (0,006 - 2,00) μg/l\nbenzo(b)fluoranten (0,006 - 2,00) μg/l\nbenzo(ghi)perylen (0,006 - 2,00) μg/l\nbenzo(k)fluoranten (0,006 - 2,00) μg/l\ndibenzo(ah)antracen (0,006 - 2,00) μg/l\nindeno(1,2,3-cd)piren (0,006 - 2,00) μg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"PB-DAO-13 wersja 01 z dnia 23.02.2021 r.","norm_bases":["PB-DAO-13 wersja 01 z dnia 23.02.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Analiz Organicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)\nZakres:\nbenzo(a)piren (0,006 - 2,00) μg/l\nbenzo(b)fluoranten (0,006 - 2,00) μg/l\nbenzo(ghi)perylen (0,006 - 2,00) μg/l\nbenzo(k)fluoranten (0,006 - 2,00) μg/l\ndibenzo(ah)antracen (0,006 - 2,00) μg/l\nindeno(1,2,3-cd)piren (0,006 - 2,00) μg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) PB-DAO-13 wersja 01 z dnia 23.02.2021 r. Woda, Scieki Stezenie wielopierscieniowych weglowodorow aromatycznych (WWA)\nZakres:\nbenzo(a)piren (0,006 - 2,00) μg/l\nbenzo(b)fluoranten (0,006 - 2,00) μg/l\nbenzo(ghi)perylen (0,006 - 2,00) μg/l\nbenzo(k)fluoranten (0,006 - 2,00) μg/l\ndibenzo(ah)antracen (0,006 - 2,00) μg/l\nindeno(1,2,3-cd)piren (0,006 - 2,00) μg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) PB-DAO-13 wersja 01 z dnia 23.02.2021 r.","categories":["water"],"row_index":523,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of polycyclic aromatic hydrocarbons (PAH)","parameters_en":[{"name":"benzo(a)pyrene","range":"(0,006 - 2,00) μg/l"},{"name":"benzo(b)fluoranthene","range":"(0,006 - 2,00) μg/l"},{"name":"benzo(ghi)perylene","range":"(0,006 - 2,00) μg/l"},{"name":"benzo(k)fluoranthene","range":"(0,006 - 2,00) μg/l"},{"name":"dibenzo(ah)anthracene","range":"(0,006 - 2,00) μg/l"},{"name":"indeno(1,2,3-cd)pyrene","range":"(0,006 - 2,00) μg/l"}],"search_en":"Water, Wastewater Concentration of polycyclic aromatic hydrocarbons (PAH) High-performance liquid chromatography with fluorescence detection (HPLC-FLD) benzo(a)pyrene benzo(b)fluoranthene benzo(ghi)perylene benzo(k)fluoranthene dibenzo(ah)anthracene indeno(1,2,3-cd)pyrene PB-DAO-13 wersja 01 z dnia 23.02.2021 r.","technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD)","test_object_en":"Water, Wastewater","search_zh":"水、污水 多环芳烃（PAHs）浓度 高效液相色谱-荧光检测法（HPLC-FLD） 苯并（a）芘 苯并（b）荧蒽 苯并（ghi）苝 苯并（k）荧蒽 二苯并(ah)蒽 茚并(1,2,3-cd)芘 PB-DAO-13 wersja 01 z dnia 23.02.2021 r.","technique_zh":"高效液相色谱-荧光检测法（HPLC-FLD）","test_object_zh":"水、污水","parameters_zh":[{"name":"苯并（a）芘","range":"(0,006 - 2,00) μg/l"},{"name":"苯并（b）荧蒽","range":"(0,006 - 2,00) μg/l"},{"name":"苯并（ghi）苝","range":"(0,006 - 2,00) μg/l"},{"name":"苯并（k）荧蒽","range":"(0,006 - 2,00) μg/l"},{"name":"二苯并(ah)蒽","range":"(0,006 - 2,00) μg/l"},{"name":"茚并(1,2,3-cd)芘","range":"(0,006 - 2,00) μg/l"}],"methodology_zh":"多环芳烃（PAHs）浓度"},{"_id":"6a8369ecaf14b9c0e7b1de2e","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)","parameters":[{"name":"naftalen","range":"(0,100 - 10,0) μg/l"},{"name":"acenaften","range":"(0,010 - 10,0) μg/l"},{"name":"acenaftylen","range":"(0,010 - 10,0) μg/l"},{"name":"fluoren","range":"(0,030 - 10,0) μg/l"},{"name":"fenantren","range":"(0,060 - 10,0) μg/l"},{"name":"antracen","range":"(0,010 - 10,0) μg/l"},{"name":"fluoranten","range":"(0,030 - 10,0) μg/l"},{"name":"piren","range":"(0,030 - 10,0) μg/l"},{"name":"benzo(a)antracen","range":"(0,010 - 10,0) μg/l"},{"name":"chryzen","range":"(0,010 - 10,0) μg/l"},{"name":"benzo(b)fluoranten","range":"(0,010 - 10,0) μg/l"},{"name":"benzo(k)fluoranten","range":"(0,010 - 10,0) μg/l"},{"name":"benzo(a)piren","range":"(0,010 - 10,0) μg/l"},{"name":"benzo(ghi)perylen","range":"(0,010 - 10,0) μg/l"},{"name":"dibenzo(ah)antracen","range":"(0,010 - 10,0) μg/l"},{"name":"indeno(1,2,3-cd)piren","range":"(0,010 - 10,0) μg/l"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)\nZakres:\nnaftalen (0,100 - 10,0) μg/l\nacenaften (0,010 - 10,0) μg/l\nacenaftylen (0,010 - 10,0) μg/l\nfluoren (0,030 - 10,0) μg/l\nfenantren (0,060 - 10,0) μg/l\nantracen (0,010 - 10,0) μg/l\nfluoranten (0,030 - 10,0) μg/l\npiren (0,030 - 10,0) μg/l\nbenzo(a)antracen (0,010 - 10,0) μg/l\nchryzen (0,010 - 10,0) μg/l\nbenzo(b)fluoranten (0,010 - 10,0) μg/l\nbenzo(k)fluoranten (0,010 - 10,0) μg/l\nbenzo(a)piren (0,010 - 10,0) μg/l\nbenzo(ghi)perylen (0,010 - 10,0) μg/l\ndibenzo(ah)antracen (0,010 - 10,0) μg/l\nindeno(1,2,3-cd)piren (0,010 - 10,0) μg/l\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"PB-DAO-11 wersja 01 z dnia 23.02.2021 r.","norm_bases":["PB-DAO-11 wersja 01 z dnia 23.02.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Analiz Organicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)\nZakres:\nnaftalen (0,100 - 10,0) μg/l\nacenaften (0,010 - 10,0) μg/l\nacenaftylen (0,010 - 10,0) μg/l\nfluoren (0,030 - 10,0) μg/l\nfenantren (0,060 - 10,0) μg/l\nantracen (0,010 - 10,0) μg/l\nfluoranten (0,030 - 10,0) μg/l\npiren (0,030 - 10,0) μg/l\nbenzo(a)antracen (0,010 - 10,0) μg/l\nchryzen (0,010 - 10,0) μg/l\nbenzo(b)fluoranten (0,010 - 10,0) μg/l\nbenzo(k)fluoranten (0,010 - 10,0) μg/l\nbenzo(a)piren (0,010 - 10,0) μg/l\nbenzo(ghi)perylen (0,010 - 10,0) μg/l\ndibenzo(ah)antracen (0,010 - 10,0) μg/l\nindeno(1,2,3-cd)piren (0,010 - 10,0) μg/l\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) PB-DAO-11 wersja 01 z dnia 23.02.2021 r. Woda, Scieki Stezenie wielopierscieniowych weglowodorow aromatycznych (WWA)\nZakres:\nnaftalen (0,100 - 10,0) μg/l\nacenaften (0,010 - 10,0) μg/l\nacenaftylen (0,010 - 10,0) μg/l\nfluoren (0,030 - 10,0) μg/l\nfenantren (0,060 - 10,0) μg/l\nantracen (0,010 - 10,0) μg/l\nfluoranten (0,030 - 10,0) μg/l\npiren (0,030 - 10,0) μg/l\nbenzo(a)antracen (0,010 - 10,0) μg/l\nchryzen (0,010 - 10,0) μg/l\nbenzo(b)fluoranten (0,010 - 10,0) μg/l\nbenzo(k)fluoranten (0,010 - 10,0) μg/l\nbenzo(a)piren (0,010 - 10,0) μg/l\nbenzo(ghi)perylen (0,010 - 10,0) μg/l\ndibenzo(ah)antracen (0,010 - 10,0) μg/l\nindeno(1,2,3-cd)piren (0,010 - 10,0) μg/l\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) PB-DAO-11 wersja 01 z dnia 23.02.2021 r.","categories":["water"],"row_index":524,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of polycyclic aromatic hydrocarbons (PAH)","parameters_en":[{"name":"naphthalene","range":"(0,100 - 10,0) μg/l"},{"name":"acenaphthene","range":"(0,010 - 10,0) μg/l"},{"name":"acenaphthylene","range":"(0,010 - 10,0) μg/l"},{"name":"fluorene","range":"(0,030 - 10,0) μg/l"},{"name":"phenanthrene","range":"(0,060 - 10,0) μg/l"},{"name":"anthracene","range":"(0,010 - 10,0) μg/l"},{"name":"fluoranthene","range":"(0,030 - 10,0) μg/l"},{"name":"pyrene","range":"(0,030 - 10,0) μg/l"},{"name":"benzo(a)anthracene","range":"(0,010 - 10,0) μg/l"},{"name":"chrysene","range":"(0,010 - 10,0) μg/l"},{"name":"benzo(b)fluoranthene","range":"(0,010 - 10,0) μg/l"},{"name":"benzo(k)fluoranthene","range":"(0,010 - 10,0) μg/l"},{"name":"benzo(a)pyrene","range":"(0,010 - 10,0) μg/l"},{"name":"benzo(ghi)perylene","range":"(0,010 - 10,0) μg/l"},{"name":"dibenzo(ah)anthracene","range":"(0,010 - 10,0) μg/l"},{"name":"indeno(1,2,3-cd)pyrene","range":"(0,010 - 10,0) μg/l"}],"search_en":"Water, Wastewater Concentration of polycyclic aromatic hydrocarbons (PAH) Gas chromatography with mass spectrometry detection (GC-MS) naphthalene acenaphthene acenaphthylene fluorene phenanthrene anthracene fluoranthene pyrene benzo(a)anthracene chrysene benzo(b)fluoranthene benzo(k)fluoranthene benzo(a)pyrene benzo(ghi)perylene dibenzo(ah)anthracene indeno(1,2,3-cd)pyrene PB-DAO-11 wersja 01 z dnia 23.02.2021 r.","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","test_object_en":"Water, Wastewater","search_zh":"水、污水 多环芳烃（PAHs）浓度 气相色谱-质谱法（GC-MS） 萘 苊 苊烯 芴 菲 蒽 荧蒽 芘 苯并（a）蒽 䓛 苯并（b）荧蒽 苯并（k）荧蒽 苯并（a）芘 苯并（ghi）苝 二苯并(ah)蒽 茚并(1,2,3-cd)芘 PB-DAO-11 wersja 01 z dnia 23.02.2021 r.","technique_zh":"气相色谱-质谱法（GC-MS）","test_object_zh":"水、污水","parameters_zh":[{"name":"萘","range":"(0,100 - 10,0) μg/l"},{"name":"苊","range":"(0,010 - 10,0) μg/l"},{"name":"苊烯","range":"(0,010 - 10,0) μg/l"},{"name":"芴","range":"(0,030 - 10,0) μg/l"},{"name":"菲","range":"(0,060 - 10,0) μg/l"},{"name":"蒽","range":"(0,010 - 10,0) μg/l"},{"name":"荧蒽","range":"(0,030 - 10,0) μg/l"},{"name":"芘","range":"(0,030 - 10,0) μg/l"},{"name":"苯并（a）蒽","range":"(0,010 - 10,0) μg/l"},{"name":"䓛","range":"(0,010 - 10,0) μg/l"},{"name":"苯并（b）荧蒽","range":"(0,010 - 10,0) μg/l"},{"name":"苯并（k）荧蒽","range":"(0,010 - 10,0) μg/l"},{"name":"苯并（a）芘","range":"(0,010 - 10,0) μg/l"},{"name":"苯并（ghi）苝","range":"(0,010 - 10,0) μg/l"},{"name":"二苯并(ah)蒽","range":"(0,010 - 10,0) μg/l"},{"name":"茚并(1,2,3-cd)芘","range":"(0,010 - 10,0) μg/l"}],"methodology_zh":"多环芳烃（PAHs）浓度"},{"_id":"6a8369ecaf14b9c0e7b1de2f","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie lotnych węglowodorów aromatycznych i alifatycznych","parameters":[{"name":"benzen","range":"(0,30 - 5000) μg/l"},{"name":"toluen","range":"(0,4 - 5000) μg/l"},{"name":"etylobenzen","range":"(0,8 - 5000) μg/l"},{"name":"o-ksylen","range":"(0,8 - 5000) μg/l"},{"name":"(m+p)-ksylen","range":"(0,8 - 10000) μg/l"},{"name":"styren","range":"(1,0 - 5000) μg/l"},{"name":"naftalen 1,0 - 5000) μg/l"},{"name":"Zakres","range":"1,2,4-trimetylobenzen (1,0 - 2500) μg/l"},{"name":"3-metylopentan","range":"(1,0 - 2500) μg/l"},{"name":"2,2,4-trimetylopentan","range":"(1,0 - 2500) μg/l"},{"name":"Suma benzyn (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)","techniques":["Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)"],"computed":[],"activity":"Stężenie lotnych węglowodorów aromatycznych i alifatycznych\nZakres:\nbenzen (0,30 - 5000) μg/l\ntoluen (0,4 - 5000) μg/l\netylobenzen (0,8 - 5000) μg/l\no-ksylen (0,8 - 5000) μg/l\n(m+p)-ksylen (0,8 - 10000) μg/l\nstyren (1,0 - 5000) μg/l\nnaftalen 1,0 - 5000) μg/l\nZakres 1,2,4-trimetylobenzen (1,0 - 2500) μg/l\n3-metylopentan (1,0 - 2500) μg/l\n2,2,4-trimetylopentan (1,0 - 2500) μg/l\nSuma benzyn (z obliczeń)\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)","reference":"PN-ISO 11423-1:2002","norm_bases":["PN-ISO 11423-1:2002"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Organicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie lotnych węglowodorów aromatycznych i alifatycznych\nZakres:\nbenzen (0,30 - 5000) μg/l\ntoluen (0,4 - 5000) μg/l\netylobenzen (0,8 - 5000) μg/l\no-ksylen (0,8 - 5000) μg/l\n(m+p)-ksylen (0,8 - 10000) μg/l\nstyren (1,0 - 5000) μg/l\nnaftalen 1,0 - 5000) μg/l\nZakres 1,2,4-trimetylobenzen (1,0 - 2500) μg/l\n3-metylopentan (1,0 - 2500) μg/l\n2,2,4-trimetylopentan (1,0 - 2500) μg/l\nSuma benzyn (z obliczeń)\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS) PN-ISO 11423-1:2002 Woda, Scieki Stezenie lotnych weglowodorow aromatycznych i alifatycznych\nZakres:\nbenzen (0,30 - 5000) μg/l\ntoluen (0,4 - 5000) μg/l\netylobenzen (0,8 - 5000) μg/l\no-ksylen (0,8 - 5000) μg/l\n(m+p)-ksylen (0,8 - 10000) μg/l\nstyren (1,0 - 5000) μg/l\nnaftalen 1,0 - 5000) μg/l\nZakres 1,2,4-trimetylobenzen (1,0 - 2500) μg/l\n3-metylopentan (1,0 - 2500) μg/l\n2,2,4-trimetylopentan (1,0 - 2500) μg/l\nSuma benzyn (z obliczen)\nMetoda chromatografii gazowej z analiza fazy nadpowierzchniowej i detekcja spektrometria mas (HS-GC-MS) PN-ISO 11423-1:2002","categories":["water"],"row_index":525,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of volatile aromatic and aliphatic hydrocarbons","parameters_en":[{"name":"benzene","range":"(0,30 - 5000) μg/l"},{"name":"toluene","range":"(0,4 - 5000) μg/l"},{"name":"ethylbenzene","range":"(0,8 - 5000) μg/l"},{"name":"o-xylene","range":"(0,8 - 5000) μg/l"},{"name":"(m+p)-xylene","range":"(0,8 - 10000) μg/l"},{"name":"styrene","range":"(1,0 - 5000) μg/l"},{"name":"naphthalene 1,0 - 5000) μg/l"},{"name":"Range","range":"1,2,4-trimetylobenzen (1,0 - 2500) μg/l"},{"name":"3-methylpentane","range":"(1,0 - 2500) μg/l"},{"name":"2,2,4-trimethylpentane","range":"(1,0 - 2500) μg/l"},{"name":"Sum of gasolines (calculated)"}],"search_en":"Water, Wastewater Concentration of volatile aromatic and aliphatic hydrocarbons Headspace gas chromatography with mass spectrometry detection (HS-GC-MS) benzene toluene ethylbenzene o-xylene (m+p)-xylene styrene naphthalene 1,0 - 5000) μg/l Range 3-methylpentane 2,2,4-trimethylpentane Sum of gasolines (calculated) PN-ISO 11423-1:2002","technique_en":"Headspace gas chromatography with mass spectrometry detection (HS-GC-MS)","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"苯","range":"(0,30 - 5000) μg/l"},{"name":"甲苯","range":"(0,4 - 5000) μg/l"},{"name":"乙苯","range":"(0,8 - 5000) μg/l"},{"name":"邻二甲苯","range":"(0,8 - 5000) μg/l"},{"name":"(间+对)-二甲苯","range":"(0,8 - 10000) μg/l"},{"name":"苯乙烯","range":"(1,0 - 5000) μg/l"},{"name":"naftalen 1,0 - 5000) μg/l"},{"name":"范围","range":"1,2,4-trimetylobenzen (1,0 - 2500) μg/l"},{"name":"3-甲基戊烷","range":"(1,0 - 2500) μg/l"},{"name":"2,2,4-trimetylopentan","range":"(1,0 - 2500) μg/l"},{"name":"Suma benzyn (z obliczeń)"}],"search_zh":"水、污水 顶空气相色谱-质谱法（HS-GC-MS） 苯 甲苯 乙苯 邻二甲苯 (间+对)-二甲苯 苯乙烯 范围 3-甲基戊烷 PN-ISO 11423-1:2002","test_object_zh":"水、污水","technique_zh":"顶空气相色谱-质谱法（HS-GC-MS）"},{"_id":"6a8369ecaf14b9c0e7b1de30","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie lotnych węglowodorów aromatycznych, chlorowcopochodnych i innych","parameters":[{"name":"dichlorometan","range":"(3,0 - 5000) μg/l"},{"name":"dibromometan","range":"(3,0 - 5000) μg/l"},{"name":"trichlorometan","range":"(1,0 - 5000) μg/l"},{"name":"tribromometan","range":"(1,0 - 2500) μg/l"},{"name":"dibromochlorometan","range":"(1,0 - 5000) μg/l"},{"name":"bromodichlorometan","range":"(1,0 - 5000) μg/l"},{"name":"tetrachlorometan","range":"(1,0 - 5000) μg/l"},{"name":"Zakres","range":"1,1-dichloroetan (1,0 - 5000) μg/l"},{"name":"1,2-dichloroetan","range":"(0,80 - 5000) μg/l"},{"name":"bromochlorometan","range":"(1,0 - 5000) μg/l"},{"name":"1,2-dibromoetan","range":"(1,0 - 5000) μg/l"},{"name":"cis-1,2-dichloroeten","range":"(1,0 - 5000) μg/l"},{"name":"trans-1,2-dichloroeten","range":"(1,0 - 5000) μg/l"},{"name":"1,1-dichloroeten","range":"(3,0 - 5000) μg/l"},{"name":"1,1,1-trichloroetan","range":"(1,0 - 5000) μg/l"},{"name":"1,1,2-trichloroetan","range":"(1,0 - 5000) μg/l"},{"name":"trichloroeten","range":"(1,0 - 5000) μg/l"},{"name":"tetrachloroeten","range":"(1,0 - 5000) μg/l"},{"name":"1,1,1,2-tetrachloroetan","range":"(1,0 - 5000) μg/l"},{"name":"1,1,2,2-tetrachloroetan","range":"(1,0 - 5000) μg/l"},{"name":"1,2-dichloropropan","range":"(1,0 - 5000) μg/l"},{"name":"1,3-dichloropropan","range":"(1,0 - 5000) μg/l"},{"name":"2,2-dichloropropan","range":"(1,0 - 5000) μg/l"},{"name":"1,2,3-trichloropropan","range":"(3,0 - 2500) μg/l"},{"name":"1,2-dibromo-3-chloropropan","range":"(3,0 - 2500) μg/l"},{"name":"1,1-dichloropropen","range":"(1,0 - 5000) μg/l"},{"name":"cis-1,3-dichloropropen","range":"(3,0 - 5000) μg/l"},{"name":"trans-1,3-dichloropropen","range":"(3,0 - 5000) μg/l"},{"name":"heksachlorobutadien","range":"(1,0 - 2500) μg/l"},{"name":"chlorek winylu","range":"(0,15 - 500) μg/l"},{"name":"chlorobenzen","range":"(1,0 - 5000) μg/l"},{"name":"bromobenzen","range":"(1,0 - 5000) μg/l"},{"name":"1,2-dichlorobenzen","range":"(1,0 - 5000) μg/l"},{"name":"1,3-dichlorobenzen","range":"(1,0 - 5000) μg/l"},{"name":"1,4-dichlorobenzen","range":"(1,0 - 5000) μg/l"},{"name":"1,2,3-trichlorobenzen","range":"(1,0 - 2500) μg/l"},{"name":"1,2,4-trichlorobenzen","range":"(1,0 - 2500) μg/l"},{"name":"1,3,5-trichlorobenzen","range":"(1,0 - 2500) μg/l"},{"name":"n-butylobenzen","range":"(1,0 - 2500) μg/l"},{"name":"sec-butylobenzen","range":"(1,0 - 2500) μg/l"},{"name":"tert-butylobenzen","range":"(1,0 - 2500) μg/l"},{"name":"izopropylobenzen","range":"(1,0 - 2500) μg/l"},{"name":"n-propylobenzen","range":"(1,0 - 2500) μg/l"},{"name":"2-chlorotoluen","range":"(1,0 - 2500) μg/l"},{"name":"4-chlorotoluen","range":"(1,0 - 2500) μg/l"},{"name":"4-izopropylotoluen","range":"(1,0 - 2500) μg/l"},{"name":"1,3,5-trimetylobenzen","range":"(1,0 - 2500) μg/l"}],"technique":"Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)","techniques":["Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)"],"computed":[],"activity":"Stężenie lotnych węglowodorów aromatycznych, chlorowcopochodnych i innych\nZakres:\ndichlorometan (3,0 - 5000) μg/l\ndibromometan (3,0 - 5000) μg/l\ntrichlorometan (1,0 - 5000) μg/l\ntribromometan (1,0 - 2500) μg/l\ndibromochlorometan (1,0 - 5000) μg/l\nbromodichlorometan (1,0 - 5000) μg/l\ntetrachlorometan (1,0 - 5000) μg/l\nZakres 1,1-dichloroetan (1,0 - 5000) μg/l\n1,2-dichloroetan (0,80 - 5000) μg/l\nbromochlorometan (1,0 - 5000) μg/l\n1,2-dibromoetan (1,0 - 5000) μg/l\ncis-1,2-dichloroeten (1,0 - 5000) μg/l\ntrans-1,2-dichloroeten (1,0 - 5000) μg/l\n1,1-dichloroeten (3,0 - 5000) μg/l\n1,1,1-trichloroetan (1,0 - 5000) μg/l\n1,1,2-trichloroetan (1,0 - 5000) μg/l\ntrichloroeten (1,0 - 5000) μg/l\ntetrachloroeten (1,0 - 5000) μg/l\n1,1,1,2-tetrachloroetan (1,0 - 5000) μg/l\n1,1,2,2-tetrachloroetan (1,0 - 5000) μg/l\n1,2-dichloropropan (1,0 - 5000) μg/l\n1,3-dichloropropan (1,0 - 5000) μg/l\n2,2-dichloropropan (1,0 - 5000) μg/l\n1,2,3-trichloropropan (3,0 - 2500) μg/l\n1,2-dibromo-3-chloropropan (3,0 - 2500) μg/l\n1,1-dichloropropen (1,0 - 5000) μg/l\ncis-1,3-dichloropropen (3,0 - 5000) μg/l\ntrans-1,3-dichloropropen (3,0 - 5000) μg/l\nheksachlorobutadien (1,0 - 2500) μg/l\nchlorek winylu (0,15 - 500) μg/l\nchlorobenzen (1,0 - 5000) μg/l\nbromobenzen (1,0 - 5000) μg/l\n1,2-dichlorobenzen (1,0 - 5000) μg/l\n1,3-dichlorobenzen (1,0 - 5000) μg/l\n1,4-dichlorobenzen (1,0 - 5000) μg/l\n1,2,3-trichlorobenzen (1,0 - 2500) μg/l\n1,2,4-trichlorobenzen (1,0 - 2500) μg/l\n1,3,5-trichlorobenzen (1,0 - 2500) μg/l\nn-butylobenzen (1,0 - 2500) μg/l\nsec-butylobenzen (1,0 - 2500) μg/l\ntert-butylobenzen (1,0 - 2500) μg/l\nizopropylobenzen (1,0 - 2500) μg/l\nn-propylobenzen (1,0 - 2500) μg/l\n2-chlorotoluen (1,0 - 2500) μg/l\n4-chlorotoluen (1,0 - 2500) μg/l\n4-izopropylotoluen (1,0 - 2500) μg/l\n1,3,5-trimetylobenzen (1,0 - 2500) μg/l\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)","reference":"PN-EN ISO 10301:2002","norm_bases":["PN-EN ISO 10301:2002"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Organicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie lotnych węglowodorów aromatycznych, chlorowcopochodnych i innych\nZakres:\ndichlorometan (3,0 - 5000) μg/l\ndibromometan (3,0 - 5000) μg/l\ntrichlorometan (1,0 - 5000) μg/l\ntribromometan (1,0 - 2500) μg/l\ndibromochlorometan (1,0 - 5000) μg/l\nbromodichlorometan (1,0 - 5000) μg/l\ntetrachlorometan (1,0 - 5000) μg/l\nZakres 1,1-dichloroetan (1,0 - 5000) μg/l\n1,2-dichloroetan (0,80 - 5000) μg/l\nbromochlorometan (1,0 - 5000) μg/l\n1,2-dibromoetan (1,0 - 5000) μg/l\ncis-1,2-dichloroeten (1,0 - 5000) μg/l\ntrans-1,2-dichloroeten (1,0 - 5000) μg/l\n1,1-dichloroeten (3,0 - 5000) μg/l\n1,1,1-trichloroetan (1,0 - 5000) μg/l\n1,1,2-trichloroetan (1,0 - 5000) μg/l\ntrichloroeten (1,0 - 5000) μg/l\ntetrachloroeten (1,0 - 5000) μg/l\n1,1,1,2-tetrachloroetan (1,0 - 5000) μg/l\n1,1,2,2-tetrachloroetan (1,0 - 5000) μg/l\n1,2-dichloropropan (1,0 - 5000) μg/l\n1,3-dichloropropan (1,0 - 5000) μg/l\n2,2-dichloropropan (1,0 - 5000) μg/l\n1,2,3-trichloropropan (3,0 - 2500) μg/l\n1,2-dibromo-3-chloropropan (3,0 - 2500) μg/l\n1,1-dichloropropen (1,0 - 5000) μg/l\ncis-1,3-dichloropropen (3,0 - 5000) μg/l\ntrans-1,3-dichloropropen (3,0 - 5000) μg/l\nheksachlorobutadien (1,0 - 2500) μg/l\nchlorek winylu (0,15 - 500) μg/l\nchlorobenzen (1,0 - 5000) μg/l\nbromobenzen (1,0 - 5000) μg/l\n1,2-dichlorobenzen (1,0 - 5000) μg/l\n1,3-dichlorobenzen (1,0 - 5000) μg/l\n1,4-dichlorobenzen (1,0 - 5000) μg/l\n1,2,3-trichlorobenzen (1,0 - 2500) μg/l\n1,2,4-trichlorobenzen (1,0 - 2500) μg/l\n1,3,5-trichlorobenzen (1,0 - 2500) μg/l\nn-butylobenzen (1,0 - 2500) μg/l\nsec-butylobenzen (1,0 - 2500) μg/l\ntert-butylobenzen (1,0 - 2500) μg/l\nizopropylobenzen (1,0 - 2500) μg/l\nn-propylobenzen (1,0 - 2500) μg/l\n2-chlorotoluen (1,0 - 2500) μg/l\n4-chlorotoluen (1,0 - 2500) μg/l\n4-izopropylotoluen (1,0 - 2500) μg/l\n1,3,5-trimetylobenzen (1,0 - 2500) μg/l\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS) PN-EN ISO 10301:2002 Woda, Scieki Stezenie lotnych weglowodorow aromatycznych, chlorowcopochodnych i innych\nZakres:\ndichlorometan (3,0 - 5000) μg/l\ndibromometan (3,0 - 5000) μg/l\ntrichlorometan (1,0 - 5000) μg/l\ntribromometan (1,0 - 2500) μg/l\ndibromochlorometan (1,0 - 5000) μg/l\nbromodichlorometan (1,0 - 5000) μg/l\ntetrachlorometan (1,0 - 5000) μg/l\nZakres 1,1-dichloroetan (1,0 - 5000) μg/l\n1,2-dichloroetan (0,80 - 5000) μg/l\nbromochlorometan (1,0 - 5000) μg/l\n1,2-dibromoetan (1,0 - 5000) μg/l\ncis-1,2-dichloroeten (1,0 - 5000) μg/l\ntrans-1,2-dichloroeten (1,0 - 5000) μg/l\n1,1-dichloroeten (3,0 - 5000) μg/l\n1,1,1-trichloroetan (1,0 - 5000) μg/l\n1,1,2-trichloroetan (1,0 - 5000) μg/l\ntrichloroeten (1,0 - 5000) μg/l\ntetrachloroeten (1,0 - 5000) μg/l\n1,1,1,2-tetrachloroetan (1,0 - 5000) μg/l\n1,1,2,2-tetrachloroetan (1,0 - 5000) μg/l\n1,2-dichloropropan (1,0 - 5000) μg/l\n1,3-dichloropropan (1,0 - 5000) μg/l\n2,2-dichloropropan (1,0 - 5000) μg/l\n1,2,3-trichloropropan (3,0 - 2500) μg/l\n1,2-dibromo-3-chloropropan (3,0 - 2500) μg/l\n1,1-dichloropropen (1,0 - 5000) μg/l\ncis-1,3-dichloropropen (3,0 - 5000) μg/l\ntrans-1,3-dichloropropen (3,0 - 5000) μg/l\nheksachlorobutadien (1,0 - 2500) μg/l\nchlorek winylu (0,15 - 500) μg/l\nchlorobenzen (1,0 - 5000) μg/l\nbromobenzen (1,0 - 5000) μg/l\n1,2-dichlorobenzen (1,0 - 5000) μg/l\n1,3-dichlorobenzen (1,0 - 5000) μg/l\n1,4-dichlorobenzen (1,0 - 5000) μg/l\n1,2,3-trichlorobenzen (1,0 - 2500) μg/l\n1,2,4-trichlorobenzen (1,0 - 2500) μg/l\n1,3,5-trichlorobenzen (1,0 - 2500) μg/l\nn-butylobenzen (1,0 - 2500) μg/l\nsec-butylobenzen (1,0 - 2500) μg/l\ntert-butylobenzen (1,0 - 2500) μg/l\nizopropylobenzen (1,0 - 2500) μg/l\nn-propylobenzen (1,0 - 2500) μg/l\n2-chlorotoluen (1,0 - 2500) μg/l\n4-chlorotoluen (1,0 - 2500) μg/l\n4-izopropylotoluen (1,0 - 2500) μg/l\n1,3,5-trimetylobenzen (1,0 - 2500) μg/l\nMetoda chromatografii gazowej z analiza fazy nadpowierzchniowej i detekcja spektrometria mas (HS-GC-MS) PN-EN ISO 10301:2002","categories":["water"],"row_index":526,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of volatile aromatic hydrocarbons, halogenated derivatives and others","parameters_en":[{"name":"dichloromethane","range":"(3,0 - 5000) μg/l"},{"name":"dibromomethane","range":"(3,0 - 5000) μg/l"},{"name":"trichloromethane","range":"(1,0 - 5000) μg/l"},{"name":"tribromomethane","range":"(1,0 - 2500) μg/l"},{"name":"dibromochloromethane","range":"(1,0 - 5000) μg/l"},{"name":"bromodichloromethane","range":"(1,0 - 5000) μg/l"},{"name":"tetrachloromethane","range":"(1,0 - 5000) μg/l"},{"name":"Range","range":"1,1-dichloroetan (1,0 - 5000) μg/l"},{"name":"1,2-dichloroethane","range":"(0,80 - 5000) μg/l"},{"name":"bromochloromethane","range":"(1,0 - 5000) μg/l"},{"name":"1,2-dibromoethane","range":"(1,0 - 5000) μg/l"},{"name":"cis-1,2-dichloroethene","range":"(1,0 - 5000) μg/l"},{"name":"trans-1,2-dichloroethene","range":"(1,0 - 5000) μg/l"},{"name":"1,1-dichloroethene","range":"(3,0 - 5000) μg/l"},{"name":"1,1,1-trichloroethane","range":"(1,0 - 5000) μg/l"},{"name":"1,1,2-trichloroethane","range":"(1,0 - 5000) μg/l"},{"name":"trichloroethene","range":"(1,0 - 5000) μg/l"},{"name":"tetrachloroethene","range":"(1,0 - 5000) μg/l"},{"name":"1,1,1,2-tetrachloroethane","range":"(1,0 - 5000) μg/l"},{"name":"1,1,2,2-tetrachloroethane","range":"(1,0 - 5000) μg/l"},{"name":"1,2-dichloropropane","range":"(1,0 - 5000) μg/l"},{"name":"1,3-dichloropropane","range":"(1,0 - 5000) μg/l"},{"name":"2,2-dichloropropane","range":"(1,0 - 5000) μg/l"},{"name":"1,2,3-trichloropropane","range":"(3,0 - 2500) μg/l"},{"name":"1,2-dibromo-3-chloropropane","range":"(3,0 - 2500) μg/l"},{"name":"1,1-dichloropropene","range":"(1,0 - 5000) μg/l"},{"name":"cis-1,3-dichloropropene","range":"(3,0 - 5000) μg/l"},{"name":"trans-1,3-dichloropropene","range":"(3,0 - 5000) μg/l"},{"name":"hexachlorobutadiene","range":"(1,0 - 2500) μg/l"},{"name":"vinyl chloride","range":"(0,15 - 500) μg/l"},{"name":"chlorobenzene","range":"(1,0 - 5000) μg/l"},{"name":"bromobenzene","range":"(1,0 - 5000) μg/l"},{"name":"1,2-dichlorobenzene","range":"(1,0 - 5000) μg/l"},{"name":"1,3-dichlorobenzene","range":"(1,0 - 5000) μg/l"},{"name":"1,4-dichlorobenzene","range":"(1,0 - 5000) μg/l"},{"name":"1,2,3-trichlorobenzene","range":"(1,0 - 2500) μg/l"},{"name":"1,2,4-trichlorobenzene","range":"(1,0 - 2500) μg/l"},{"name":"1,3,5-trichlorobenzene","range":"(1,0 - 2500) μg/l"},{"name":"n-butylbenzene","range":"(1,0 - 2500) μg/l"},{"name":"sec-butylbenzene","range":"(1,0 - 2500) μg/l"},{"name":"tert-butylbenzene","range":"(1,0 - 2500) μg/l"},{"name":"isopropylbenzene","range":"(1,0 - 2500) μg/l"},{"name":"n-propylbenzene","range":"(1,0 - 2500) μg/l"},{"name":"2-chlorotoluene","range":"(1,0 - 2500) μg/l"},{"name":"4-chlorotoluene","range":"(1,0 - 2500) μg/l"},{"name":"4-isopropyltoluene","range":"(1,0 - 2500) μg/l"},{"name":"1,3,5-trimethylbenzene","range":"(1,0 - 2500) μg/l"}],"search_en":"Water, Wastewater Concentration of volatile aromatic hydrocarbons, halogenated derivatives and others Headspace gas chromatography with mass spectrometry detection (HS-GC-MS) dichloromethane dibromomethane trichloromethane tribromomethane dibromochloromethane bromodichloromethane tetrachloromethane Range 1,2-dichloroethane bromochloromethane 1,2-dibromoethane cis-1,2-dichloroethene trans-1,2-dichloroethene 1,1-dichloroethene 1,1,1-trichloroethane 1,1,2-trichloroethane trichloroethene tetrachloroethene 1,1,1,2-tetrachloroethane 1,1,2,2-tetrachloroethane 1,2-dichloropropane 1,3-dichloropropane 2,2-dichloropropane 1,2,3-trichloropropane 1,2-dibromo-3-chloropropane 1,1-dichloropropene cis-1,3-dichloropropene trans-1,3-dichloropropene hexachlorobutadiene vinyl chloride chlorobenzene bromobenzene 1,2-dichlorobenzene 1,3-dichlorobenzene 1,4-dichlorobenzene 1,2,3-trichlorobenzene 1,2,4-trichlorobenzene 1,3,5-trichlorobenzene n-butylbenzene sec-butylbenzene tert-butylbenzene isopropylbenzene n-propylbenzene 2-chlorotoluene 4-chlorotoluene 4-isopropyltoluene 1,3,5-trimethylbenzene PN-EN ISO 10301:2002","technique_en":"Headspace gas chromatography with mass spectrometry detection (HS-GC-MS)","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"二氯甲烷","range":"(3,0 - 5000) μg/l"},{"name":"二溴甲烷","range":"(3,0 - 5000) μg/l"},{"name":"三氯甲烷","range":"(1,0 - 5000) μg/l"},{"name":"三溴甲烷","range":"(1,0 - 2500) μg/l"},{"name":"二溴一氯甲烷","range":"(1,0 - 5000) μg/l"},{"name":"一溴二氯甲烷","range":"(1,0 - 5000) μg/l"},{"name":"四氯化碳","range":"(1,0 - 5000) μg/l"},{"name":"范围","range":"1,1-dichloroetan (1,0 - 5000) μg/l"},{"name":"1,2-二氯乙烷","range":"(0,80 - 5000) μg/l"},{"name":"溴氯甲烷","range":"(1,0 - 5000) μg/l"},{"name":"1,2-二溴乙烷","range":"(1,0 - 5000) μg/l"},{"name":"顺式-1,2-二氯乙烯","range":"(1,0 - 5000) μg/l"},{"name":"反式-1,2-二氯乙烯","range":"(1,0 - 5000) μg/l"},{"name":"1,1-二氯乙烯","range":"(3,0 - 5000) μg/l"},{"name":"1,1,1-三氯乙烷","range":"(1,0 - 5000) μg/l"},{"name":"1,1,2-三氯乙烷","range":"(1,0 - 5000) μg/l"},{"name":"三氯乙烯","range":"(1,0 - 5000) μg/l"},{"name":"四氯乙烯","range":"(1,0 - 5000) μg/l"},{"name":"1,1,1,2-四氯乙烷","range":"(1,0 - 5000) μg/l"},{"name":"1,1,2,2-四氯乙烷","range":"(1,0 - 5000) μg/l"},{"name":"1,2-二氯丙烷","range":"(1,0 - 5000) μg/l"},{"name":"1,3-二氯丙烷","range":"(1,0 - 5000) μg/l"},{"name":"2,2-二氯丙烷","range":"(1,0 - 5000) μg/l"},{"name":"1,2,3-三氯丙烷","range":"(3,0 - 2500) μg/l"},{"name":"1,2-二溴-3-氯丙烷","range":"(3,0 - 2500) μg/l"},{"name":"1,1-二氯丙烯","range":"(1,0 - 5000) μg/l"},{"name":"顺式-1,3-二氯丙烯","range":"(3,0 - 5000) μg/l"},{"name":"反式-1,3-二氯丙烯","range":"(3,0 - 5000) μg/l"},{"name":"六氯丁二烯","range":"(1,0 - 2500) μg/l"},{"name":"氯乙烯","range":"(0,15 - 500) μg/l"},{"name":"氯苯","range":"(1,0 - 5000) μg/l"},{"name":"溴苯","range":"(1,0 - 5000) μg/l"},{"name":"1,2-二氯苯","range":"(1,0 - 5000) μg/l"},{"name":"1,3-二氯苯","range":"(1,0 - 5000) μg/l"},{"name":"1,4-二氯苯","range":"(1,0 - 5000) μg/l"},{"name":"1,2,3-三氯苯","range":"(1,0 - 2500) μg/l"},{"name":"1,2,4-三氯苯","range":"(1,0 - 2500) μg/l"},{"name":"1,3,5-三氯苯","range":"(1,0 - 2500) μg/l"},{"name":"正丁苯","range":"(1,0 - 2500) μg/l"},{"name":"仲丁苯","range":"(1,0 - 2500) μg/l"},{"name":"tert-butylobenzen","range":"(1,0 - 2500) μg/l"},{"name":"异丙苯","range":"(1,0 - 2500) μg/l"},{"name":"正丙苯","range":"(1,0 - 2500) μg/l"},{"name":"2-chlorotoluen","range":"(1,0 - 2500) μg/l"},{"name":"4-chlorotoluen","range":"(1,0 - 2500) μg/l"},{"name":"4-izopropylotoluen","range":"(1,0 - 2500) μg/l"},{"name":"1,3,5-三甲苯","range":"(1,0 - 2500) μg/l"}],"search_zh":"水、污水 顶空气相色谱-质谱法（HS-GC-MS） 二氯甲烷 二溴甲烷 三氯甲烷 三溴甲烷 二溴一氯甲烷 一溴二氯甲烷 四氯化碳 范围 1,2-二氯乙烷 溴氯甲烷 1,2-二溴乙烷 顺式-1,2-二氯乙烯 反式-1,2-二氯乙烯 1,1-二氯乙烯 1,1,1-三氯乙烷 1,1,2-三氯乙烷 三氯乙烯 四氯乙烯 1,1,1,2-四氯乙烷 1,1,2,2-四氯乙烷 1,2-二氯丙烷 1,3-二氯丙烷 2,2-二氯丙烷 1,2,3-三氯丙烷 1,2-二溴-3-氯丙烷 1,1-二氯丙烯 顺式-1,3-二氯丙烯 反式-1,3-二氯丙烯 六氯丁二烯 氯乙烯 氯苯 溴苯 1,2-二氯苯 1,3-二氯苯 1,4-二氯苯 1,2,3-三氯苯 1,2,4-三氯苯 1,3,5-三氯苯 正丁苯 仲丁苯 异丙苯 正丙苯 1,3,5-三甲苯 PN-EN ISO 10301:2002","test_object_zh":"水、污水","technique_zh":"顶空气相色谱-质谱法（HS-GC-MS）"},{"_id":"6a8369ecaf14b9c0e7b1de31","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie lotnych węglowodorów aromatycznych, chlorowcopochodnych i innych","parameters":[{"name":"eter metylowo-tert-butylowy (MTBE)"},{"name":"Zakres","range":"(3,0 - 2500) μg/l"},{"name":"eter metylowo-tert-amylowy (TAME)","range":"(3,0 - 2500) μg/l"},{"name":"eter etylowo-tert-amylowy (TAEE)","range":"(3,0 - 2500) μg/l"},{"name":"eter etylowo-tert-butylowy (ETBE)","range":"(3,0 - 2500) μg/l"}],"technique":"Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)","techniques":["Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)"],"computed":[],"activity":"Stężenie lotnych węglowodorów aromatycznych, chlorowcopochodnych i innych\nZakres:\neter metylowo-tert-butylowy (MTBE)\nZakres (3,0 - 2500) μg/l\neter metylowo-tert-amylowy (TAME) (3,0 - 2500) μg/l\neter etylowo-tert-amylowy (TAEE) (3,0 - 2500) μg/l\neter etylowo-tert-butylowy (ETBE) (3,0 - 2500) μg/l\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)","reference":"PN-EN ISO 10301:2002","norm_bases":["PN-EN ISO 10301:2002"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Organicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie lotnych węglowodorów aromatycznych, chlorowcopochodnych i innych\nZakres:\neter metylowo-tert-butylowy (MTBE)\nZakres (3,0 - 2500) μg/l\neter metylowo-tert-amylowy (TAME) (3,0 - 2500) μg/l\neter etylowo-tert-amylowy (TAEE) (3,0 - 2500) μg/l\neter etylowo-tert-butylowy (ETBE) (3,0 - 2500) μg/l\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS) PN-EN ISO 10301:2002 Woda, Scieki Stezenie lotnych weglowodorow aromatycznych, chlorowcopochodnych i innych\nZakres:\neter metylowo-tert-butylowy (MTBE)\nZakres (3,0 - 2500) μg/l\neter metylowo-tert-amylowy (TAME) (3,0 - 2500) μg/l\neter etylowo-tert-amylowy (TAEE) (3,0 - 2500) μg/l\neter etylowo-tert-butylowy (ETBE) (3,0 - 2500) μg/l\nMetoda chromatografii gazowej z analiza fazy nadpowierzchniowej i detekcja spektrometria mas (HS-GC-MS) PN-EN ISO 10301:2002","categories":["water"],"row_index":527,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of volatile aromatic hydrocarbons, halogenated derivatives and others","parameters_en":[{"name":"methyl tert-butyl ether (MTBE)"},{"name":"Range","range":"(3,0 - 2500) μg/l"},{"name":"tert-amyl methyl ether (TAME)","range":"(3,0 - 2500) μg/l"},{"name":"tert-amyl ethyl ether (TAEE)","range":"(3,0 - 2500) μg/l"},{"name":"ethyl tert-butyl ether (ETBE)","range":"(3,0 - 2500) μg/l"}],"search_en":"Water, Wastewater Concentration of volatile aromatic hydrocarbons, halogenated derivatives and others Headspace gas chromatography with mass spectrometry detection (HS-GC-MS) methyl tert-butyl ether (MTBE) Range tert-amyl methyl ether (TAME) tert-amyl ethyl ether (TAEE) ethyl tert-butyl ether (ETBE) PN-EN ISO 10301:2002","technique_en":"Headspace gas chromatography with mass spectrometry detection (HS-GC-MS)","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"eter metylowo-tert-butylowy (MTBE)"},{"name":"范围","range":"(3,0 - 2500) μg/l"},{"name":"eter metylowo-tert-amylowy (TAME)","range":"(3,0 - 2500) μg/l"},{"name":"eter etylowo-tert-amylowy (TAEE)","range":"(3,0 - 2500) μg/l"},{"name":"eter etylowo-tert-butylowy (ETBE)","range":"(3,0 - 2500) μg/l"}],"search_zh":"水、污水 顶空气相色谱-质谱法（HS-GC-MS） 范围 PN-EN ISO 10301:2002","test_object_zh":"水、污水","technique_zh":"顶空气相色谱-质谱法（HS-GC-MS）"},{"_id":"6a8369ecaf14b9c0e7b1de32","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda, Ścieki (opadowe i oczyszczone)","methodology":"Stężenie węglowodorów C10 - C40 (olej mineralny C10 - C40, indeks oleju mineralnego)","parameters":[{"name":"Zakres","range":"(0,10 - 100) mg/l"},{"name":"Stężenie frakcji: węglowodorów C10 - C12 węglowodorów C12 - C35 węglowodorów C35 - C40 węglowodorów C12 - C16 węglowodorów C16 - C35 węglowodorów C10 - C21 węglowodorów C22 - C40 węglowodorów C10 - C28 (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie węglowodorów C10 - C40 (olej mineralny C10 - C40, indeks oleju mineralnego)\nZakres:\nZakres (0,10 - 100) mg/l\nStężenie frakcji: węglowodorów C10 - C12 węglowodorów C12 - C35 węglowodorów C35 - C40 węglowodorów C12 - C16 węglowodorów C16 - C35 węglowodorów C10 - C21 węglowodorów C22 - C40 węglowodorów C10 - C28 (z obliczeń)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN ISO 9377-2:2003 | PB-DAO-09 wersja 01 z dnia 23.02.2021 r.","norm_bases":["PN-EN ISO 9377-2:2003","PB-DAO-09 wersja 01 z dnia 23.02.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Analiz Organicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki (opadowe i oczyszczone) Stężenie węglowodorów C10 - C40 (olej mineralny C10 - C40, indeks oleju mineralnego)\nZakres:\nZakres (0,10 - 100) mg/l\nStężenie frakcji: węglowodorów C10 - C12 węglowodorów C12 - C35 węglowodorów C35 - C40 węglowodorów C12 - C16 węglowodorów C16 - C35 węglowodorów C10 - C21 węglowodorów C22 - C40 węglowodorów C10 - C28 (z obliczeń)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN ISO 9377-2:2003 | PB-DAO-09 wersja 01 z dnia 23.02.2021 r. Woda, Scieki (opadowe i oczyszczone) Stezenie weglowodorow C10 - C40 (olej mineralny C10 - C40, indeks oleju mineralnego)\nZakres:\nZakres (0,10 - 100) mg/l\nStezenie frakcji: weglowodorow C10 - C12 weglowodorow C12 - C35 weglowodorow C35 - C40 weglowodorow C12 - C16 weglowodorow C16 - C35 weglowodorow C10 - C21 weglowodorow C22 - C40 weglowodorow C10 - C28 (z obliczen)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN ISO 9377-2:2003 | PB-DAO-09 wersja 01 z dnia 23.02.2021 r.","categories":["water","petro"],"row_index":528,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of C10 - C40 hydrocarbons (mineral oil C10 - C40, mineral oil index)","parameters_en":[{"name":"Range","range":"(0,10 - 100) mg/l"},{"name":"Concentration of fractions: hydrocarbons C10 - C12 hydrocarbons C12 - C35 hydrocarbons C35 - C40 hydrocarbons C12 - C16 hydrocarbons C16 - C35 hydrocarbons C10 - C21 hydrocarbons C22 - C40 hydrocarbons C10 - C28 (calculated)"}],"search_en":"Water, Wastewater (rainwater and treated) Concentration of C10 - C40 hydrocarbons (mineral oil C10 - C40, mineral oil index) Gas chromatography with flame ionization detection (GC-FID) Range Concentration of fractions: hydrocarbons C10 - C12 hydrocarbons C12 - C35 hydrocarbons C35 - C40 hydrocarbons C12 - C16 hydrocarbons C16 - C35 hydrocarbons C10 - C21 hydrocarbons C22 - C40 hydrocarbons C10 - C28 (calculated) PN-EN ISO 9377-2:2003 | PB-DAO-09 wersja 01 z dnia 23.02.2021 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Water, Wastewater (rainwater and treated)","parameters_zh":[{"name":"范围","range":"(0,10 - 100) mg/l"},{"name":"Stężenie frakcji: węglowodorów C10 - C12 węglowodorów C12 - C35 węglowodorów C35 - C40 węglowodorów C12 - C16 węglowodorów C16 - C35 węglowodorów C10 - C21 węglowodorów C22 - C40 węglowodorów C10 - C28 (z obliczeń)"}],"search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-EN ISO 9377-2:2003 | PB-DAO-09 wersja 01 z dnia 23.02.2021 r.","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a8369ecaf14b9c0e7b1de33","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Stężenie lotnych chlorowcopochodnych węglowodorów (THM)","parameters":[{"name":"dibromochlorometan","range":"(4,00 - 500) μg/l"},{"name":"bromodichlorometan","range":"(4,00 - 500) μg/l"},{"name":"trichlorometan","range":"(4,00 - 500) μg/l"},{"name":"tribromometan","range":"(4,00 - 500) μg/l"}],"technique":"Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)","techniques":["Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)"],"computed":[],"activity":"Stężenie lotnych chlorowcopochodnych węglowodorów (THM)\nZakres:\ndibromochlorometan (4,00 - 500) μg/l\nbromodichlorometan (4,00 - 500) μg/l\ntrichlorometan (4,00 - 500) μg/l\ntribromometan (4,00 - 500) μg/l\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)","reference":"PN-EN ISO 10301:2002","norm_bases":["PN-EN ISO 10301:2002"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Organicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Stężenie lotnych chlorowcopochodnych węglowodorów (THM)\nZakres:\ndibromochlorometan (4,00 - 500) μg/l\nbromodichlorometan (4,00 - 500) μg/l\ntrichlorometan (4,00 - 500) μg/l\ntribromometan (4,00 - 500) μg/l\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS) PN-EN ISO 10301:2002 Woda na plywalniach Stezenie lotnych chlorowcopochodnych weglowodorow (THM)\nZakres:\ndibromochlorometan (4,00 - 500) μg/l\nbromodichlorometan (4,00 - 500) μg/l\ntrichlorometan (4,00 - 500) μg/l\ntribromometan (4,00 - 500) μg/l\nMetoda chromatografii gazowej z analiza fazy nadpowierzchniowej i detekcja spektrometria mas (HS-GC-MS) PN-EN ISO 10301:2002","categories":["water"],"row_index":529,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of volatile halogenated hydrocarbons (THM)","parameters_en":[{"name":"dibromochloromethane","range":"(4,00 - 500) μg/l"},{"name":"bromodichloromethane","range":"(4,00 - 500) μg/l"},{"name":"trichloromethane","range":"(4,00 - 500) μg/l"},{"name":"tribromomethane","range":"(4,00 - 500) μg/l"}],"search_en":"Swimming pool water Concentration of volatile halogenated hydrocarbons (THM) Headspace gas chromatography with mass spectrometry detection (HS-GC-MS) dibromochloromethane bromodichloromethane trichloromethane tribromomethane PN-EN ISO 10301:2002","technique_en":"Headspace gas chromatography with mass spectrometry detection (HS-GC-MS)","test_object_en":"Swimming pool water","search_zh":"游泳池水 顶空气相色谱-质谱法（HS-GC-MS） 二溴一氯甲烷 一溴二氯甲烷 三氯甲烷 三溴甲烷 PN-EN ISO 10301:2002","test_object_zh":"游泳池水","parameters_zh":[{"name":"二溴一氯甲烷","range":"(4,00 - 500) μg/l"},{"name":"一溴二氯甲烷","range":"(4,00 - 500) μg/l"},{"name":"三氯甲烷","range":"(4,00 - 500) μg/l"},{"name":"三溴甲烷","range":"(4,00 - 500) μg/l"}],"technique_zh":"顶空气相色谱-质谱法（HS-GC-MS）"},{"_id":"6a8369ecaf14b9c0e7b1de34","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)","parameters":[{"name":"benzo(a)piren","range":"(0,003 - 2,00) μg/l"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)\nbenzo(a)piren (0,003 - 2,00) μg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"PB-DAO-13 wersja 01 z dnia 23.02.2021 r.","norm_bases":["PB-DAO-13 wersja 01 z dnia 23.02.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Analiz Organicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)\nbenzo(a)piren (0,003 - 2,00) μg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) PB-DAO-13 wersja 01 z dnia 23.02.2021 r. Woda do spozycia przez ludzi Stezenie wielopierscieniowych weglowodorow aromatycznych (WWA)\nbenzo(a)piren (0,003 - 2,00) μg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) PB-DAO-13 wersja 01 z dnia 23.02.2021 r.","categories":["water"],"row_index":530,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of polycyclic aromatic hydrocarbons (PAH)","parameters_en":[{"name":"benzo(a)pyrene","range":"(0,003 - 2,00) μg/l"}],"search_en":"Water intended for human consumption Concentration of polycyclic aromatic hydrocarbons (PAH) High-performance liquid chromatography with fluorescence detection (HPLC-FLD) benzo(a)pyrene PB-DAO-13 wersja 01 z dnia 23.02.2021 r.","technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD)","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 多环芳烃（PAHs）浓度 高效液相色谱-荧光检测法（HPLC-FLD） 苯并（a）芘 PB-DAO-13 wersja 01 z dnia 23.02.2021 r.","technique_zh":"高效液相色谱-荧光检测法（HPLC-FLD）","test_object_zh":"生活饮用水","parameters_zh":[{"name":"苯并（a）芘","range":"(0,003 - 2,00) μg/l"}],"methodology_zh":"多环芳烃（PAHs）浓度"},{"_id":"6a8369ecaf14b9c0e7b1de35","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie pestycydów – pochodnych fenylomocznika","parameters":[{"name":"diuron","range":"(0,030 - 1,00) μg/l"},{"name":"linuron","range":"(0,030 - 1,00) μg/l"},{"name":"isoproturon","range":"(0,030 - 1,00) μg/l"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV/Vis)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV/Vis)"],"computed":[],"activity":"Stężenie pestycydów – pochodnych fenylomocznika\nZakres:\ndiuron (0,030 - 1,00) μg/l\nlinuron (0,030 - 1,00) μg/l\nisoproturon (0,030 - 1,00) μg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV/Vis)","reference":"PB-DAO-12 wersja 02 z dnia 23.02.2023 r.","norm_bases":["PB-DAO-12 wersja 02 z dnia 23.02.2023 r."],"lab_section":"Pracownia Środowiskowa, Dział Analiz Organicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie pestycydów – pochodnych fenylomocznika\nZakres:\ndiuron (0,030 - 1,00) μg/l\nlinuron (0,030 - 1,00) μg/l\nisoproturon (0,030 - 1,00) μg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV/Vis) PB-DAO-12 wersja 02 z dnia 23.02.2023 r. Woda Stezenie pestycydow – pochodnych fenylomocznika\nZakres:\ndiuron (0,030 - 1,00) μg/l\nlinuron (0,030 - 1,00) μg/l\nisoproturon (0,030 - 1,00) μg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC-UV/Vis) PB-DAO-12 wersja 02 z dnia 23.02.2023 r.","categories":["water"],"row_index":531,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of pesticides – phenylurea derivatives","parameters_en":[{"name":"diuron","range":"(0,030 - 1,00) μg/l"},{"name":"linuron","range":"(0,030 - 1,00) μg/l"},{"name":"isoproturon","range":"(0,030 - 1,00) μg/l"}],"search_en":"Water Concentration of pesticides – phenylurea derivatives High-performance liquid chromatography with spectrophotometric detection (HPLC-UV/Vis) diuron linuron isoproturon PB-DAO-12 wersja 02 z dnia 23.02.2023 r.","technique_en":"High-performance liquid chromatography with spectrophotometric detection (HPLC-UV/Vis)","test_object_en":"Water","search_zh":"水 高效液相色谱-分光光度检测法（HPLC-UV/Vis） 敌草隆 利谷隆 PB-DAO-12 wersja 02 z dnia 23.02.2023 r.","test_object_zh":"水","technique_zh":"高效液相色谱-分光光度检测法（HPLC-UV/Vis）","parameters_zh":[{"name":"敌草隆","range":"(0,030 - 1,00) μg/l"},{"name":"利谷隆","range":"(0,030 - 1,00) μg/l"},{"name":"isoproturon","range":"(0,030 - 1,00) μg/l"}]},{"_id":"6a8369ecaf14b9c0e7b1de36","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie akryloamidu","parameters":[{"name":"Zakres","range":"(0,075 - 1,0) μg/l"}],"technique":"Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","techniques":["Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)"],"computed":[],"activity":"Stężenie akryloamidu\nZakres (0,075 - 1,0) μg/l\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","reference":"PB-DAO-14 wersja 01 z dnia 23.02.2021 r.","norm_bases":["PB-DAO-14 wersja 01 z dnia 23.02.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Analiz Organicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie akryloamidu\nZakres (0,075 - 1,0) μg/l\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) PB-DAO-14 wersja 01 z dnia 23.02.2021 r. Woda Stezenie akryloamidu\nZakres (0,075 - 1,0) μg/l\nMetoda chromatografii gazowej z detekcja wychwytu elektronow (GC-ECD) PB-DAO-14 wersja 01 z dnia 23.02.2021 r.","categories":["water"],"row_index":532,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Acrylamide concentration","parameters_en":[{"name":"Range","range":"(0,075 - 1,0) μg/l"}],"search_en":"Water Acrylamide concentration Gas chromatography with electron capture detection (GC-ECD) Range PB-DAO-14 wersja 01 z dnia 23.02.2021 r.","technique_en":"Gas chromatography with electron capture detection (GC-ECD)","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,075 - 1,0) μg/l"}],"search_zh":"水 丙烯酰胺浓度 气相色谱-电子捕获检测法（GC-ECD） 范围 PB-DAO-14 wersja 01 z dnia 23.02.2021 r.","technique_zh":"气相色谱-电子捕获检测法（GC-ECD）","test_object_zh":"水","methodology_zh":"丙烯酰胺浓度"},{"_id":"6a8369ecaf14b9c0e7b1de37","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie epichlorohydryny","parameters":[{"name":"Zakres","range":"(0,030 - 1,00) μg/l"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Stężenie epichlorohydryny\nZakres (0,030 - 1,00) μg/l\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"PN-EN 14207:2005","norm_bases":["PN-EN 14207:2005"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Organicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie epichlorohydryny\nZakres (0,030 - 1,00) μg/l\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) PN-EN 14207:2005 Woda Stezenie epichlorohydryny\nZakres (0,030 - 1,00) μg/l\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) PN-EN 14207:2005","categories":["water"],"row_index":533,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Epichlorohydrin concentration","parameters_en":[{"name":"Range","range":"(0,030 - 1,00) μg/l"}],"search_en":"Water Epichlorohydrin concentration Gas chromatography with mass spectrometry detection (GC-MS) Range PN-EN 14207:2005","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,030 - 1,00) μg/l"}],"search_zh":"水 环氧氯丙烷浓度 气相色谱-质谱法（GC-MS） 范围 PN-EN 14207:2005","technique_zh":"气相色谱-质谱法（GC-MS）","test_object_zh":"水","methodology_zh":"环氧氯丙烷浓度"},{"_id":"6a8369ecaf14b9c0e7b1de38","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie węglowodorów C10 - C40 (olej mineralny C10-C40, indeks oleju mineralnego)","parameters":[{"name":"Zakres","range":"(1,00 - 100) mg/l"},{"name":"Stężenie frakcji: węglowodorów C10 - C12 węglowodorów C12 - C35 węglowodorów C35 - C40 węglowodorów C12 - C16 węglowodorów C16 - C35 węglowodorów C10 - C21 węglowodorów C22 - C40 węglowodorów C10 - C28 (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie węglowodorów C10 - C40 (olej mineralny C10-C40, indeks oleju mineralnego)\nZakres:\nZakres (1,00 - 100) mg/l\nStężenie frakcji: węglowodorów C10 - C12 węglowodorów C12 - C35 węglowodorów C35 - C40 węglowodorów C12 - C16 węglowodorów C16 - C35 węglowodorów C10 - C21 węglowodorów C22 - C40 węglowodorów C10 - C28 (z obliczeń)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN ISO 9377-2:2003 | PB-DAO-09 wersja 01 z dnia 23.02.2021 r.","norm_bases":["PN-EN ISO 9377-2:2003","PB-DAO-09 wersja 01 z dnia 23.02.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Analiz Organicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie węglowodorów C10 - C40 (olej mineralny C10-C40, indeks oleju mineralnego)\nZakres:\nZakres (1,00 - 100) mg/l\nStężenie frakcji: węglowodorów C10 - C12 węglowodorów C12 - C35 węglowodorów C35 - C40 węglowodorów C12 - C16 węglowodorów C16 - C35 węglowodorów C10 - C21 węglowodorów C22 - C40 węglowodorów C10 - C28 (z obliczeń)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN ISO 9377-2:2003 | PB-DAO-09 wersja 01 z dnia 23.02.2021 r. Scieki Stezenie weglowodorow C10 - C40 (olej mineralny C10-C40, indeks oleju mineralnego)\nZakres:\nZakres (1,00 - 100) mg/l\nStezenie frakcji: weglowodorow C10 - C12 weglowodorow C12 - C35 weglowodorow C35 - C40 weglowodorow C12 - C16 weglowodorow C16 - C35 weglowodorow C10 - C21 weglowodorow C22 - C40 weglowodorow C10 - C28 (z obliczen)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN ISO 9377-2:2003 | PB-DAO-09 wersja 01 z dnia 23.02.2021 r.","categories":["water","petro"],"row_index":534,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of C10 - C40 hydrocarbons (mineral oil C10-C40, mineral oil index)","parameters_en":[{"name":"Range","range":"(1,00 - 100) mg/l"},{"name":"Concentration of fractions: hydrocarbons C10 - C12 hydrocarbons C12 - C35 hydrocarbons C35 - C40 hydrocarbons C12 - C16 hydrocarbons C16 - C35 hydrocarbons C10 - C21 hydrocarbons C22 - C40 hydrocarbons C10 - C28 (calculated)"}],"search_en":"Wastewater Concentration of C10 - C40 hydrocarbons (mineral oil C10-C40, mineral oil index) Gas chromatography with flame ionization detection (GC-FID) Range Concentration of fractions: hydrocarbons C10 - C12 hydrocarbons C12 - C35 hydrocarbons C35 - C40 hydrocarbons C12 - C16 hydrocarbons C16 - C35 hydrocarbons C10 - C21 hydrocarbons C22 - C40 hydrocarbons C10 - C28 (calculated) PN-EN ISO 9377-2:2003 | PB-DAO-09 wersja 01 z dnia 23.02.2021 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(1,00 - 100) mg/l"},{"name":"Stężenie frakcji: węglowodorów C10 - C12 węglowodorów C12 - C35 węglowodorów C35 - C40 węglowodorów C12 - C16 węglowodorów C16 - C35 węglowodorów C10 - C21 węglowodorów C22 - C40 węglowodorów C10 - C28 (z obliczeń)"}],"search_zh":"污水 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-EN ISO 9377-2:2003 | PB-DAO-09 wersja 01 z dnia 23.02.2021 r.","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"污水"},{"_id":"6a8369ecaf14b9c0e7b1de39","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA)","parameters":[{"name":"naftalen","range":"(0,050 - 100) mg/kg"},{"name":"acenaftylen","range":"(0,050 - 100) mg/kg"},{"name":"acenaften","range":"(0,050 - 100) mg/kg"},{"name":"fluoren","range":"(0,050 - 100) mg/kg"},{"name":"fenantren","range":"(0,050 - 100) mg/kg"},{"name":"antracen","range":"(0,050 - 100) mg/kg"},{"name":"fluoranten","range":"(0,050 - 100) mg/kg"},{"name":"piren","range":"(0,050 - 100) mg/kg"},{"name":"benzo(a)antracen","range":"(0,050 - 100) mg/kg"},{"name":"chryzen","range":"(0,050 - 100) mg/kg"},{"name":"benzo(b)fluoranten","range":"(0,050 - 100) mg/kg"},{"name":"benzo(k)fluoranten","range":"(0,050 - 100) mg/kg"},{"name":"benzo(a)piren","range":"(0,050 - 100) mg/kg"},{"name":"dibenzo(ah)antracen","range":"(0,050 - 100) mg/kg"},{"name":"benzo(ghi)perylen","range":"(0,050 - 100) mg/kg"},{"name":"indeno","range":"(1,2,3-cd)piren"},{"name":"Zakres","range":"(0,050 - 100) mg/kg"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA)\nZakres:\nnaftalen (0,050 - 100) mg/kg\nacenaftylen (0,050 - 100) mg/kg\nacenaften (0,050 - 100) mg/kg\nfluoren (0,050 - 100) mg/kg\nfenantren (0,050 - 100) mg/kg\nantracen (0,050 - 100) mg/kg\nfluoranten (0,050 - 100) mg/kg\npiren (0,050 - 100) mg/kg\nbenzo(a)antracen (0,050 - 100) mg/kg\nchryzen (0,050 - 100) mg/kg\nbenzo(b)fluoranten (0,050 - 100) mg/kg\nbenzo(k)fluoranten (0,050 - 100) mg/kg\nbenzo(a)piren (0,050 - 100) mg/kg\ndibenzo(ah)antracen (0,050 - 100) mg/kg\nbenzo(ghi)perylen (0,050 - 100) mg/kg\nindeno (1,2,3-cd)piren\nZakres (0,050 - 100) mg/kg\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"PN-ISO 18287:2008","norm_bases":["PN-ISO 18287:2008"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Organicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA)\nZakres:\nnaftalen (0,050 - 100) mg/kg\nacenaftylen (0,050 - 100) mg/kg\nacenaften (0,050 - 100) mg/kg\nfluoren (0,050 - 100) mg/kg\nfenantren (0,050 - 100) mg/kg\nantracen (0,050 - 100) mg/kg\nfluoranten (0,050 - 100) mg/kg\npiren (0,050 - 100) mg/kg\nbenzo(a)antracen (0,050 - 100) mg/kg\nchryzen (0,050 - 100) mg/kg\nbenzo(b)fluoranten (0,050 - 100) mg/kg\nbenzo(k)fluoranten (0,050 - 100) mg/kg\nbenzo(a)piren (0,050 - 100) mg/kg\ndibenzo(ah)antracen (0,050 - 100) mg/kg\nbenzo(ghi)perylen (0,050 - 100) mg/kg\nindeno (1,2,3-cd)piren\nZakres (0,050 - 100) mg/kg\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) PN-ISO 18287:2008 Gleba Zawartosc wielopierscieniowych weglowodorow aromatycznych (WWA)\nZakres:\nnaftalen (0,050 - 100) mg/kg\nacenaftylen (0,050 - 100) mg/kg\nacenaften (0,050 - 100) mg/kg\nfluoren (0,050 - 100) mg/kg\nfenantren (0,050 - 100) mg/kg\nantracen (0,050 - 100) mg/kg\nfluoranten (0,050 - 100) mg/kg\npiren (0,050 - 100) mg/kg\nbenzo(a)antracen (0,050 - 100) mg/kg\nchryzen (0,050 - 100) mg/kg\nbenzo(b)fluoranten (0,050 - 100) mg/kg\nbenzo(k)fluoranten (0,050 - 100) mg/kg\nbenzo(a)piren (0,050 - 100) mg/kg\ndibenzo(ah)antracen (0,050 - 100) mg/kg\nbenzo(ghi)perylen (0,050 - 100) mg/kg\nindeno (1,2,3-cd)piren\nZakres (0,050 - 100) mg/kg\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) PN-ISO 18287:2008","categories":["environment"],"row_index":535,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Polycyclic aromatic hydrocarbons (PAH) content","parameters_en":[{"name":"naphthalene","range":"(0,050 - 100) mg/kg"},{"name":"acenaphthylene","range":"(0,050 - 100) mg/kg"},{"name":"acenaphthene","range":"(0,050 - 100) mg/kg"},{"name":"fluorene","range":"(0,050 - 100) mg/kg"},{"name":"phenanthrene","range":"(0,050 - 100) mg/kg"},{"name":"anthracene","range":"(0,050 - 100) mg/kg"},{"name":"fluoranthene","range":"(0,050 - 100) mg/kg"},{"name":"pyrene","range":"(0,050 - 100) mg/kg"},{"name":"benzo(a)anthracene","range":"(0,050 - 100) mg/kg"},{"name":"chrysene","range":"(0,050 - 100) mg/kg"},{"name":"benzo(b)fluoranthene","range":"(0,050 - 100) mg/kg"},{"name":"benzo(k)fluoranthene","range":"(0,050 - 100) mg/kg"},{"name":"benzo(a)pyrene","range":"(0,050 - 100) mg/kg"},{"name":"dibenzo(ah)anthracene","range":"(0,050 - 100) mg/kg"},{"name":"benzo(ghi)perylene","range":"(0,050 - 100) mg/kg"},{"name":"indeno","range":"(1,2,3-cd)piren"},{"name":"Range","range":"(0,050 - 100) mg/kg"}],"search_en":"Soil Polycyclic aromatic hydrocarbons (PAH) content Gas chromatography with mass spectrometry detection (GC-MS) naphthalene acenaphthylene acenaphthene fluorene phenanthrene anthracene fluoranthene pyrene benzo(a)anthracene chrysene benzo(b)fluoranthene benzo(k)fluoranthene benzo(a)pyrene dibenzo(ah)anthracene benzo(ghi)perylene indeno Range PN-ISO 18287:2008","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","test_object_en":"Soil","parameters_zh":[{"name":"萘","range":"(0,050 - 100) mg/kg"},{"name":"苊烯","range":"(0,050 - 100) mg/kg"},{"name":"苊","range":"(0,050 - 100) mg/kg"},{"name":"芴","range":"(0,050 - 100) mg/kg"},{"name":"菲","range":"(0,050 - 100) mg/kg"},{"name":"蒽","range":"(0,050 - 100) mg/kg"},{"name":"荧蒽","range":"(0,050 - 100) mg/kg"},{"name":"芘","range":"(0,050 - 100) mg/kg"},{"name":"苯并（a）蒽","range":"(0,050 - 100) mg/kg"},{"name":"䓛","range":"(0,050 - 100) mg/kg"},{"name":"苯并（b）荧蒽","range":"(0,050 - 100) mg/kg"},{"name":"苯并（k）荧蒽","range":"(0,050 - 100) mg/kg"},{"name":"苯并（a）芘","range":"(0,050 - 100) mg/kg"},{"name":"二苯并(ah)蒽","range":"(0,050 - 100) mg/kg"},{"name":"苯并（ghi）苝","range":"(0,050 - 100) mg/kg"},{"name":"茚","range":"(1,2,3-cd)piren"},{"name":"范围","range":"(0,050 - 100) mg/kg"}],"search_zh":"土壤 多环芳烃（PAHs）含量 气相色谱-质谱法（GC-MS） 萘 苊烯 苊 芴 菲 蒽 荧蒽 芘 苯并（a）蒽 䓛 苯并（b）荧蒽 苯并（k）荧蒽 苯并（a）芘 二苯并(ah)蒽 苯并（ghi）苝 茚 范围 PN-ISO 18287:2008","technique_zh":"气相色谱-质谱法（GC-MS）","test_object_zh":"土壤","methodology_zh":"多环芳烃（PAHs）含量"},{"_id":"6a8369ecaf14b9c0e7b1de3a","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość oleju mineralnego (węglowodory C10-C40, C12-C35, C10-C28, C10-C12, C12-C16, C16-C21, C21-C35, C35-C40)","parameters":[{"name":"Zakres","range":"(20,0 - 4000) mg/kg"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość oleju mineralnego (węglowodory C10-C40, C12-C35, C10-C28, C10-C12, C12-C16, C16-C21, C21-C35, C35-C40)\nZakres (20,0 - 4000) mg/kg\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN ISO 16703:2011 | PB-DAO-23 wersja 01 z dnia 23.02.2024 r.","norm_bases":["PN-EN ISO 16703:2011","PB-DAO-23 wersja 01 z dnia 23.02.2024 r."],"lab_section":"Pracownia Środowiskowa, Dział Analiz Organicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość oleju mineralnego (węglowodory C10-C40, C12-C35, C10-C28, C10-C12, C12-C16, C16-C21, C21-C35, C35-C40)\nZakres (20,0 - 4000) mg/kg\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN ISO 16703:2011 | PB-DAO-23 wersja 01 z dnia 23.02.2024 r. Gleba Zawartosc oleju mineralnego (weglowodory C10-C40, C12-C35, C10-C28, C10-C12, C12-C16, C16-C21, C21-C35, C35-C40)\nZakres (20,0 - 4000) mg/kg\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN ISO 16703:2011 | PB-DAO-23 wersja 01 z dnia 23.02.2024 r.","categories":["environment","petro"],"row_index":536,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mineral oil content (C10-C40, C12-C35, C10-C28, C10-C12, C12-C16, C16-C21, C21-C35, C35-C40 hydrocarbons)","parameters_en":[{"name":"Range","range":"(20,0 - 4000) mg/kg"}],"search_en":"Soil Mineral oil content (C10-C40, C12-C35, C10-C28, C10-C12, C12-C16, C16-C21, C21-C35, C35-C40 hydrocarbons) Gas chromatography with flame ionization detection (GC-FID) Range PN-EN ISO 16703:2011 | PB-DAO-23 wersja 01 z dnia 23.02.2024 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"(20,0 - 4000) mg/kg"}],"search_zh":"土壤 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-EN ISO 16703:2011 | PB-DAO-23 wersja 01 z dnia 23.02.2024 r.","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"土壤"},{"_id":"6a8369ecaf14b9c0e7b1de3b","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość polichlorowanych bifenyli","parameters":[{"name":"PCB 28","range":"(0,002 - 5,0) mg/kg"},{"name":"PCB 52","range":"(0,002 - 5,0) mg/kg"},{"name":"PCB 101","range":"(0,002 - 5,0) mg/kg"},{"name":"PCB 118","range":"(0,002 - 5,0) mg/kg"},{"name":"PCB 138","range":"(0,002 - 5,0) mg/kg"},{"name":"PCB 153","range":"(0,002 - 5,0) mg/kg"},{"name":"PCB 180","range":"(0,002 - 5,0) mg/kg"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Zawartość polichlorowanych bifenyli\nZakres:\nPCB 28 (0,002 - 5,0) mg/kg\nPCB 52 (0,002 - 5,0) mg/kg\nPCB 101 (0,002 - 5,0) mg/kg\nPCB 118 (0,002 - 5,0) mg/kg\nPCB 138 (0,002 - 5,0) mg/kg\nPCB 153 (0,002 - 5,0) mg/kg\nPCB 180 (0,002 - 5,0) mg/kg\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"PB-DAO-03 wersja 01 z dnia 23.02.2021 r.","norm_bases":["PB-DAO-03 wersja 01 z dnia 23.02.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Analiz Organicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość polichlorowanych bifenyli\nZakres:\nPCB 28 (0,002 - 5,0) mg/kg\nPCB 52 (0,002 - 5,0) mg/kg\nPCB 101 (0,002 - 5,0) mg/kg\nPCB 118 (0,002 - 5,0) mg/kg\nPCB 138 (0,002 - 5,0) mg/kg\nPCB 153 (0,002 - 5,0) mg/kg\nPCB 180 (0,002 - 5,0) mg/kg\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) PB-DAO-03 wersja 01 z dnia 23.02.2021 r. Gleba Zawartosc polichlorowanych bifenyli\nZakres:\nPCB 28 (0,002 - 5,0) mg/kg\nPCB 52 (0,002 - 5,0) mg/kg\nPCB 101 (0,002 - 5,0) mg/kg\nPCB 118 (0,002 - 5,0) mg/kg\nPCB 138 (0,002 - 5,0) mg/kg\nPCB 153 (0,002 - 5,0) mg/kg\nPCB 180 (0,002 - 5,0) mg/kg\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) PB-DAO-03 wersja 01 z dnia 23.02.2021 r.","categories":["environment"],"row_index":537,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Polychlorinated biphenyl content","parameters_en":[{"name":"PCB 28","range":"(0,002 - 5,0) mg/kg"},{"name":"PCB 52","range":"(0,002 - 5,0) mg/kg"},{"name":"PCB 101","range":"(0,002 - 5,0) mg/kg"},{"name":"PCB 118","range":"(0,002 - 5,0) mg/kg"},{"name":"PCB 138","range":"(0,002 - 5,0) mg/kg"},{"name":"PCB 153","range":"(0,002 - 5,0) mg/kg"},{"name":"PCB 180","range":"(0,002 - 5,0) mg/kg"}],"search_en":"Soil Polychlorinated biphenyl content Gas chromatography with mass spectrometry detection (GC-MS) PCB 28 PCB 52 PCB 101 PCB 118 PCB 138 PCB 153 PCB 180 PB-DAO-03 wersja 01 z dnia 23.02.2021 r.","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","test_object_en":"Soil","search_zh":"土壤 多氯联苯含量 气相色谱-质谱法（GC-MS） PCB 28 PCB 52 PCB 101 PCB 118 PCB 138 PCB 153 PCB 180 PB-DAO-03 wersja 01 z dnia 23.02.2021 r.","technique_zh":"气相色谱-质谱法（GC-MS）","test_object_zh":"土壤","parameters_zh":[{"name":"PCB 28","range":"(0,002 - 5,0) mg/kg"},{"name":"PCB 52","range":"(0,002 - 5,0) mg/kg"},{"name":"PCB 101","range":"(0,002 - 5,0) mg/kg"},{"name":"PCB 118","range":"(0,002 - 5,0) mg/kg"},{"name":"PCB 138","range":"(0,002 - 5,0) mg/kg"},{"name":"PCB 153","range":"(0,002 - 5,0) mg/kg"},{"name":"PCB 180","range":"(0,002 - 5,0) mg/kg"}],"methodology_zh":"多氯联苯含量"},{"_id":"6a8369ecaf14b9c0e7b1de3c","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość ftalanów i chloronaftalenów","parameters":[{"name":"ftalan dimetylu","range":"(0,050 - 100) mg/kg"},{"name":"ftalan dietylu","range":"(0,050 - 100) mg/kg"},{"name":"ftalan dibutylu","range":"(0,050 - 100) mg/kg"},{"name":"ftalan benzylu butylu"},{"name":"Zakres","range":"(0,050 - 100) mg/kg"},{"name":"ftalan di-izo-butylu","range":"(0,050 - 100) mg/kg"},{"name":"ftalan bis","range":"(2-etyloheksylu)"},{"name":"(0,050 - 100) mg/kg"},{"name":"ftalan dioktylu","range":"(0,050 - 100) mg/kg"},{"name":"(1+2)-chloronaftalen"},{"name":"(0,010 - 20,0) mg/kg"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Zawartość ftalanów i chloronaftalenów\nZakres:\nftalan dimetylu (0,050 - 100) mg/kg\nftalan dietylu (0,050 - 100) mg/kg\nftalan dibutylu (0,050 - 100) mg/kg\nftalan benzylu butylu\nZakres (0,050 - 100) mg/kg\nftalan di-izo-butylu (0,050 - 100) mg/kg\nftalan bis (2-etyloheksylu)\n(0,050 - 100) mg/kg\nftalan dioktylu (0,050 - 100) mg/kg\n(1+2)-chloronaftalen\n(0,010 - 20,0) mg/kg\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"PB-DAO-01 wersja 01 Z dnia 23.02.2021 r.","norm_bases":["PB-DAO-01 wersja 01 Z dnia 23.02.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Analiz Organicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość ftalanów i chloronaftalenów\nZakres:\nftalan dimetylu (0,050 - 100) mg/kg\nftalan dietylu (0,050 - 100) mg/kg\nftalan dibutylu (0,050 - 100) mg/kg\nftalan benzylu butylu\nZakres (0,050 - 100) mg/kg\nftalan di-izo-butylu (0,050 - 100) mg/kg\nftalan bis (2-etyloheksylu)\n(0,050 - 100) mg/kg\nftalan dioktylu (0,050 - 100) mg/kg\n(1+2)-chloronaftalen\n(0,010 - 20,0) mg/kg\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) PB-DAO-01 wersja 01 Z dnia 23.02.2021 r. Gleba Zawartosc ftalanow i chloronaftalenow\nZakres:\nftalan dimetylu (0,050 - 100) mg/kg\nftalan dietylu (0,050 - 100) mg/kg\nftalan dibutylu (0,050 - 100) mg/kg\nftalan benzylu butylu\nZakres (0,050 - 100) mg/kg\nftalan di-izo-butylu (0,050 - 100) mg/kg\nftalan bis (2-etyloheksylu)\n(0,050 - 100) mg/kg\nftalan dioktylu (0,050 - 100) mg/kg\n(1+2)-chloronaftalen\n(0,010 - 20,0) mg/kg\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) PB-DAO-01 wersja 01 Z dnia 23.02.2021 r.","categories":["environment"],"row_index":538,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phthalate and chloronaphthalene content","parameters_en":[{"name":"dimethyl phthalate","range":"(0,050 - 100) mg/kg"},{"name":"diethyl phthalate","range":"(0,050 - 100) mg/kg"},{"name":"dibutyl phthalate","range":"(0,050 - 100) mg/kg"},{"name":"benzyl butyl phthalate"},{"name":"Range","range":"(0,050 - 100) mg/kg"},{"name":"di-iso-butyl phthalate","range":"(0,050 - 100) mg/kg"},{"name":"bis phthalate","range":"(2-etyloheksylu)"},{"name":"(0,050 - 100) mg/kg"},{"name":"dioctyl phthalate","range":"(0,050 - 100) mg/kg"},{"name":"(1+2)-chloronaphthalene"},{"name":"(0,010 - 20,0) mg/kg"}],"search_en":"Soil Phthalate and chloronaphthalene content Gas chromatography with mass spectrometry detection (GC-MS) dimethyl phthalate diethyl phthalate dibutyl phthalate benzyl butyl phthalate Range di-iso-butyl phthalate bis phthalate (0,050 - 100) mg/kg dioctyl phthalate (1+2)-chloronaphthalene (0,010 - 20,0) mg/kg PB-DAO-01 wersja 01 Z dnia 23.02.2021 r.","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","test_object_en":"Soil","parameters_zh":[{"name":"邻苯二甲酸二甲酯","range":"(0,050 - 100) mg/kg"},{"name":"邻苯二甲酸二乙酯","range":"(0,050 - 100) mg/kg"},{"name":"邻苯二甲酸二丁酯","range":"(0,050 - 100) mg/kg"},{"name":"邻苯二甲酸丁苄酯"},{"name":"范围","range":"(0,050 - 100) mg/kg"},{"name":"ftalan di-izo-butylu","range":"(0,050 - 100) mg/kg"},{"name":"邻苯二甲酸二酯","range":"(2-etyloheksylu)"},{"name":"(0,050 - 100) mg/kg"},{"name":"ftalan dioktylu","range":"(0,050 - 100) mg/kg"},{"name":"(1+2)-chloronaftalen"},{"name":"(0,010 - 20,0) mg/kg"}],"search_zh":"土壤 气相色谱-质谱法（GC-MS） 邻苯二甲酸二甲酯 邻苯二甲酸二乙酯 邻苯二甲酸二丁酯 邻苯二甲酸丁苄酯 范围 邻苯二甲酸二酯 PB-DAO-01 wersja 01 Z dnia 23.02.2021 r.","technique_zh":"气相色谱-质谱法（GC-MS）","test_object_zh":"土壤"},{"_id":"6a8369ecaf14b9c0e7b1de3d","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość chlorobenzenów","parameters":[{"name":"Zakres","range":"1,2,3,4-tetrachlorobenzen"},{"name":"Zakres","range":"(0,005 - 20,0) mg/kg"},{"name":"Pentachlorobenzen","range":"(0,005 - 20,0) mg/kg"},{"name":"heksachlorobenzen","range":"(0,005 - 20,0) mg/kg"},{"name":"1,2,3,5+1,2,4,5-tetrachlorobenzen","range":"(0,010 - 40,0) mg/kg"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Zawartość chlorobenzenów\nZakres:\nZakres 1,2,3,4-tetrachlorobenzen\nZakres (0,005 - 20,0) mg/kg\nPentachlorobenzen (0,005 - 20,0) mg/kg\nheksachlorobenzen (0,005 - 20,0) mg/kg\n1,2,3,5+1,2,4,5-tetrachlorobenzen (0,010 - 40,0) mg/kg\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"PB-DAO-03 wersja 01 z dnia 23.02.2021 r.","norm_bases":["PB-DAO-03 wersja 01 z dnia 23.02.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Analiz Organicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość chlorobenzenów\nZakres:\nZakres 1,2,3,4-tetrachlorobenzen\nZakres (0,005 - 20,0) mg/kg\nPentachlorobenzen (0,005 - 20,0) mg/kg\nheksachlorobenzen (0,005 - 20,0) mg/kg\n1,2,3,5+1,2,4,5-tetrachlorobenzen (0,010 - 40,0) mg/kg\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) PB-DAO-03 wersja 01 z dnia 23.02.2021 r. Gleba Zawartosc chlorobenzenow\nZakres:\nZakres 1,2,3,4-tetrachlorobenzen\nZakres (0,005 - 20,0) mg/kg\nPentachlorobenzen (0,005 - 20,0) mg/kg\nheksachlorobenzen (0,005 - 20,0) mg/kg\n1,2,3,5+1,2,4,5-tetrachlorobenzen (0,010 - 40,0) mg/kg\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) PB-DAO-03 wersja 01 z dnia 23.02.2021 r.","categories":["environment"],"row_index":539,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chlorobenzene content","parameters_en":[{"name":"Range","range":"1,2,3,4-tetrachlorobenzen"},{"name":"Range","range":"(0,005 - 20,0) mg/kg"},{"name":"Pentachlorobenzene","range":"(0,005 - 20,0) mg/kg"},{"name":"hexachlorobenzene","range":"(0,005 - 20,0) mg/kg"},{"name":"1,2,3,5+1,2,4,5-tetrachlorobenzene","range":"(0,010 - 40,0) mg/kg"}],"search_en":"Soil Chlorobenzene content Gas chromatography with mass spectrometry detection (GC-MS) Range Range Pentachlorobenzene hexachlorobenzene 1,2,3,5+1,2,4,5-tetrachlorobenzene PB-DAO-03 wersja 01 z dnia 23.02.2021 r.","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"1,2,3,4-tetrachlorobenzen"},{"name":"范围","range":"(0,005 - 20,0) mg/kg"},{"name":"五氯苯","range":"(0,005 - 20,0) mg/kg"},{"name":"六氯苯","range":"(0,005 - 20,0) mg/kg"},{"name":"1,2,3,5+1,2,4,5-tetrachlorobenzen","range":"(0,010 - 40,0) mg/kg"}],"search_zh":"土壤 氯苯类含量 气相色谱-质谱法（GC-MS） 范围 范围 五氯苯 六氯苯 PB-DAO-03 wersja 01 z dnia 23.02.2021 r.","technique_zh":"气相色谱-质谱法（GC-MS）","test_object_zh":"土壤","methodology_zh":"氯苯类含量"},{"_id":"6a8369ecaf14b9c0e7b1de3e","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość związków lotnych","parameters":[{"name":"benzen","range":"(0,020 - 250) mg/kg"},{"name":"toluen","range":"(0,020 - 250) mg/kg"},{"name":"etylobenzen","range":"(0,020 - 250) mg/kg"},{"name":"o-ksylen","range":"(0,020 - 250) mg/kg"},{"name":"(m+p)-ksylen","range":"(0,040 - 500) mg/kg"},{"name":"styren","range":"(0,020 - 250) mg/kg"},{"name":"naftalen","range":"(0,040 - 10,0) mg/kg"},{"name":"dichlorometan","range":"(0,010 - 20,0) mg/kg"},{"name":"dibromometan","range":"(0,020 - 10,0) mg/kg"},{"name":"trichlorometan","range":"(0,010 - 20,0) mg/kg"},{"name":"tribromometan","range":"(0,020 - 10,0) mg/kg"},{"name":"dibromochlorometan","range":"(0,020 - 10,0) mg/kg"},{"name":"bromodichlorometan","range":"(0,020 - 10,0) mg/kg"},{"name":"tetrachlorometan","range":"(0,010 - 20,0) mg/kg"},{"name":"Zakres","range":"1,1-dichloroetan (0,020 - 10,0) mg/kg"},{"name":"1,2-dichloroetan","range":"(0,010 - 20,0) mg/kg"},{"name":"bromochlorometan","range":"(0,020 - 10,0) mg/kg"},{"name":"1,2-dibromoetan","range":"(0,020 - 10,0) mg/kg"},{"name":"cis-1,2-dichloroeten","range":"(0,010 - 10,0) mg/kg"},{"name":"trans-1,2-dichloroeten","range":"(0,010 - 10,0) mg/kg"},{"name":"1,1-dichloroeten","range":"(0,010 - 10,0) mg/kg"},{"name":"1,1,1-trichloroetan","range":"(0,020 - 10,0) mg/kg"},{"name":"1,1,2-trichloroetan","range":"(0,010 - 20,0) mg/kg"},{"name":"trichloroeten","range":"(0,010 - 10,0) mg/kg"},{"name":"tetrachloroeten","range":"(0,010 - 10,0) mg/kg"},{"name":"1,1,1,2-tetrachloroetan","range":"(0,020 - 10,0) mg/kg"},{"name":"1,1,2,2-tetrachloroetan","range":"(0,010 - 20,0) mg/kg"},{"name":"1,2-dichloropropan","range":"(0,040 - 10,0) mg/kg"},{"name":"1,3-dichloropropan","range":"(0,040 - 10,0) mg/kg"},{"name":"2,2-dichloropropan","range":"(0,040 - 10,0) mg/kg"},{"name":"1,2,3-trichloropropan","range":"(0,040 - 10,0) mg/kg"},{"name":"1,2-dibromo-3-chloropropan","range":"(0,040 - 10,0) mg/kg"},{"name":"1,1-dichloropropen","range":"(0,040 - 10,0) mg/kg"},{"name":"cis-1,3-dichloropropen","range":"(0,040 - 10,0) mg/kg"},{"name":"trans-1,3-dichloropropen","range":"(0,040 - 10,0) mg/kg"},{"name":"heksachlorobutadien","range":"(0,020 - 10,0) mg/kg"},{"name":"chlorek winylu","range":"(0,010 - 20,0) mg/kg"},{"name":"chloroetan","range":"(0,010 - 20,0) mg/kg"},{"name":"chlorobenzen","range":"(0,010 - 20,0) mg/kg"},{"name":"bromobenzen","range":"(0,020 - 10,0) mg/kg"},{"name":"1,2-dichlorobenzen","range":"(0,010 - 20,0) mg/kg"},{"name":"1,3-dichlorobenzen","range":"(0,010 - 20,0) mg/kg"},{"name":"1,4-dichlorobenzen","range":"(0,010 - 20,0) mg/kg"},{"name":"1,2,3-trichlorobenzen","range":"(0,010 - 20,0) mg/kg"},{"name":"1,2,4-Trichlorobenzen","range":"(0,010 - 20,0) mg/kg"}],"technique":"Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)","techniques":["Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)"],"computed":[],"activity":"Zawartość związków lotnych\nZakres:\nbenzen (0,020 - 250) mg/kg\ntoluen (0,020 - 250) mg/kg\netylobenzen (0,020 - 250) mg/kg\no-ksylen (0,020 - 250) mg/kg\n(m+p)-ksylen (0,040 - 500) mg/kg\nstyren (0,020 - 250) mg/kg\nnaftalen (0,040 - 10,0) mg/kg\ndichlorometan (0,010 - 20,0) mg/kg\ndibromometan (0,020 - 10,0) mg/kg\ntrichlorometan (0,010 - 20,0) mg/kg\ntribromometan (0,020 - 10,0) mg/kg\ndibromochlorometan (0,020 - 10,0) mg/kg\nbromodichlorometan (0,020 - 10,0) mg/kg\ntetrachlorometan (0,010 - 20,0) mg/kg\nZakres 1,1-dichloroetan (0,020 - 10,0) mg/kg\n1,2-dichloroetan (0,010 - 20,0) mg/kg\nbromochlorometan (0,020 - 10,0) mg/kg\n1,2-dibromoetan (0,020 - 10,0) mg/kg\ncis-1,2-dichloroeten (0,010 - 10,0) mg/kg\ntrans-1,2-dichloroeten (0,010 - 10,0) mg/kg\n1,1-dichloroeten (0,010 - 10,0) mg/kg\n1,1,1-trichloroetan (0,020 - 10,0) mg/kg\n1,1,2-trichloroetan (0,010 - 20,0) mg/kg\ntrichloroeten (0,010 - 10,0) mg/kg\ntetrachloroeten (0,010 - 10,0) mg/kg\n1,1,1,2-tetrachloroetan (0,020 - 10,0) mg/kg\n1,1,2,2-tetrachloroetan (0,010 - 20,0) mg/kg\n1,2-dichloropropan (0,040 - 10,0) mg/kg\n1,3-dichloropropan (0,040 - 10,0) mg/kg\n2,2-dichloropropan (0,040 - 10,0) mg/kg\n1,2,3-trichloropropan (0,040 - 10,0) mg/kg\n1,2-dibromo-3-chloropropan (0,040 - 10,0) mg/kg\n1,1-dichloropropen (0,040 - 10,0) mg/kg\ncis-1,3-dichloropropen (0,040 - 10,0) mg/kg\ntrans-1,3-dichloropropen (0,040 - 10,0) mg/kg\nheksachlorobutadien (0,020 - 10,0) mg/kg\nchlorek winylu (0,010 - 20,0) mg/kg\nchloroetan (0,010 - 20,0) mg/kg\nchlorobenzen (0,010 - 20,0) mg/kg\nbromobenzen (0,020 - 10,0) mg/kg\n1,2-dichlorobenzen (0,010 - 20,0) mg/kg\n1,3-dichlorobenzen (0,010 - 20,0) mg/kg\n1,4-dichlorobenzen (0,010 - 20,0) mg/kg\n1,2,3-trichlorobenzen (0,010 - 20,0) mg/kg\n1,2,4-Trichlorobenzen (0,010 - 20,0) mg/kg\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)","reference":"PN-EN ISO 22155:2016-07","norm_bases":["PN-EN ISO 22155:2016-07"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Organicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość związków lotnych\nZakres:\nbenzen (0,020 - 250) mg/kg\ntoluen (0,020 - 250) mg/kg\netylobenzen (0,020 - 250) mg/kg\no-ksylen (0,020 - 250) mg/kg\n(m+p)-ksylen (0,040 - 500) mg/kg\nstyren (0,020 - 250) mg/kg\nnaftalen (0,040 - 10,0) mg/kg\ndichlorometan (0,010 - 20,0) mg/kg\ndibromometan (0,020 - 10,0) mg/kg\ntrichlorometan (0,010 - 20,0) mg/kg\ntribromometan (0,020 - 10,0) mg/kg\ndibromochlorometan (0,020 - 10,0) mg/kg\nbromodichlorometan (0,020 - 10,0) mg/kg\ntetrachlorometan (0,010 - 20,0) mg/kg\nZakres 1,1-dichloroetan (0,020 - 10,0) mg/kg\n1,2-dichloroetan (0,010 - 20,0) mg/kg\nbromochlorometan (0,020 - 10,0) mg/kg\n1,2-dibromoetan (0,020 - 10,0) mg/kg\ncis-1,2-dichloroeten (0,010 - 10,0) mg/kg\ntrans-1,2-dichloroeten (0,010 - 10,0) mg/kg\n1,1-dichloroeten (0,010 - 10,0) mg/kg\n1,1,1-trichloroetan (0,020 - 10,0) mg/kg\n1,1,2-trichloroetan (0,010 - 20,0) mg/kg\ntrichloroeten (0,010 - 10,0) mg/kg\ntetrachloroeten (0,010 - 10,0) mg/kg\n1,1,1,2-tetrachloroetan (0,020 - 10,0) mg/kg\n1,1,2,2-tetrachloroetan (0,010 - 20,0) mg/kg\n1,2-dichloropropan (0,040 - 10,0) mg/kg\n1,3-dichloropropan (0,040 - 10,0) mg/kg\n2,2-dichloropropan (0,040 - 10,0) mg/kg\n1,2,3-trichloropropan (0,040 - 10,0) mg/kg\n1,2-dibromo-3-chloropropan (0,040 - 10,0) mg/kg\n1,1-dichloropropen (0,040 - 10,0) mg/kg\ncis-1,3-dichloropropen (0,040 - 10,0) mg/kg\ntrans-1,3-dichloropropen (0,040 - 10,0) mg/kg\nheksachlorobutadien (0,020 - 10,0) mg/kg\nchlorek winylu (0,010 - 20,0) mg/kg\nchloroetan (0,010 - 20,0) mg/kg\nchlorobenzen (0,010 - 20,0) mg/kg\nbromobenzen (0,020 - 10,0) mg/kg\n1,2-dichlorobenzen (0,010 - 20,0) mg/kg\n1,3-dichlorobenzen (0,010 - 20,0) mg/kg\n1,4-dichlorobenzen (0,010 - 20,0) mg/kg\n1,2,3-trichlorobenzen (0,010 - 20,0) mg/kg\n1,2,4-Trichlorobenzen (0,010 - 20,0) mg/kg\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS) PN-EN ISO 22155:2016-07 Gleba Zawartosc zwiazkow lotnych\nZakres:\nbenzen (0,020 - 250) mg/kg\ntoluen (0,020 - 250) mg/kg\netylobenzen (0,020 - 250) mg/kg\no-ksylen (0,020 - 250) mg/kg\n(m+p)-ksylen (0,040 - 500) mg/kg\nstyren (0,020 - 250) mg/kg\nnaftalen (0,040 - 10,0) mg/kg\ndichlorometan (0,010 - 20,0) mg/kg\ndibromometan (0,020 - 10,0) mg/kg\ntrichlorometan (0,010 - 20,0) mg/kg\ntribromometan (0,020 - 10,0) mg/kg\ndibromochlorometan (0,020 - 10,0) mg/kg\nbromodichlorometan (0,020 - 10,0) mg/kg\ntetrachlorometan (0,010 - 20,0) mg/kg\nZakres 1,1-dichloroetan (0,020 - 10,0) mg/kg\n1,2-dichloroetan (0,010 - 20,0) mg/kg\nbromochlorometan (0,020 - 10,0) mg/kg\n1,2-dibromoetan (0,020 - 10,0) mg/kg\ncis-1,2-dichloroeten (0,010 - 10,0) mg/kg\ntrans-1,2-dichloroeten (0,010 - 10,0) mg/kg\n1,1-dichloroeten (0,010 - 10,0) mg/kg\n1,1,1-trichloroetan (0,020 - 10,0) mg/kg\n1,1,2-trichloroetan (0,010 - 20,0) mg/kg\ntrichloroeten (0,010 - 10,0) mg/kg\ntetrachloroeten (0,010 - 10,0) mg/kg\n1,1,1,2-tetrachloroetan (0,020 - 10,0) mg/kg\n1,1,2,2-tetrachloroetan (0,010 - 20,0) mg/kg\n1,2-dichloropropan (0,040 - 10,0) mg/kg\n1,3-dichloropropan (0,040 - 10,0) mg/kg\n2,2-dichloropropan (0,040 - 10,0) mg/kg\n1,2,3-trichloropropan (0,040 - 10,0) mg/kg\n1,2-dibromo-3-chloropropan (0,040 - 10,0) mg/kg\n1,1-dichloropropen (0,040 - 10,0) mg/kg\ncis-1,3-dichloropropen (0,040 - 10,0) mg/kg\ntrans-1,3-dichloropropen (0,040 - 10,0) mg/kg\nheksachlorobutadien (0,020 - 10,0) mg/kg\nchlorek winylu (0,010 - 20,0) mg/kg\nchloroetan (0,010 - 20,0) mg/kg\nchlorobenzen (0,010 - 20,0) mg/kg\nbromobenzen (0,020 - 10,0) mg/kg\n1,2-dichlorobenzen (0,010 - 20,0) mg/kg\n1,3-dichlorobenzen (0,010 - 20,0) mg/kg\n1,4-dichlorobenzen (0,010 - 20,0) mg/kg\n1,2,3-trichlorobenzen (0,010 - 20,0) mg/kg\n1,2,4-Trichlorobenzen (0,010 - 20,0) mg/kg\nMetoda chromatografii gazowej z analiza fazy nadpowierzchniowej i detekcja spektrometria mas (HS-GC-MS) PN-EN ISO 22155:2016-07","categories":["environment"],"row_index":540,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Volatile compound content","parameters_en":[{"name":"benzene","range":"(0,020 - 250) mg/kg"},{"name":"toluene","range":"(0,020 - 250) mg/kg"},{"name":"ethylbenzene","range":"(0,020 - 250) mg/kg"},{"name":"o-xylene","range":"(0,020 - 250) mg/kg"},{"name":"(m+p)-xylene","range":"(0,040 - 500) mg/kg"},{"name":"styrene","range":"(0,020 - 250) mg/kg"},{"name":"naphthalene","range":"(0,040 - 10,0) mg/kg"},{"name":"dichloromethane","range":"(0,010 - 20,0) mg/kg"},{"name":"dibromomethane","range":"(0,020 - 10,0) mg/kg"},{"name":"trichloromethane","range":"(0,010 - 20,0) mg/kg"},{"name":"tribromomethane","range":"(0,020 - 10,0) mg/kg"},{"name":"dibromochloromethane","range":"(0,020 - 10,0) mg/kg"},{"name":"bromodichloromethane","range":"(0,020 - 10,0) mg/kg"},{"name":"tetrachloromethane","range":"(0,010 - 20,0) mg/kg"},{"name":"Range","range":"1,1-dichloroetan (0,020 - 10,0) mg/kg"},{"name":"1,2-dichloroethane","range":"(0,010 - 20,0) mg/kg"},{"name":"bromochloromethane","range":"(0,020 - 10,0) mg/kg"},{"name":"1,2-dibromoethane","range":"(0,020 - 10,0) mg/kg"},{"name":"cis-1,2-dichloroethene","range":"(0,010 - 10,0) mg/kg"},{"name":"trans-1,2-dichloroethene","range":"(0,010 - 10,0) mg/kg"},{"name":"1,1-dichloroethene","range":"(0,010 - 10,0) mg/kg"},{"name":"1,1,1-trichloroethane","range":"(0,020 - 10,0) mg/kg"},{"name":"1,1,2-trichloroethane","range":"(0,010 - 20,0) mg/kg"},{"name":"trichloroethene","range":"(0,010 - 10,0) mg/kg"},{"name":"tetrachloroethene","range":"(0,010 - 10,0) mg/kg"},{"name":"1,1,1,2-tetrachloroethane","range":"(0,020 - 10,0) mg/kg"},{"name":"1,1,2,2-tetrachloroethane","range":"(0,010 - 20,0) mg/kg"},{"name":"1,2-dichloropropane","range":"(0,040 - 10,0) mg/kg"},{"name":"1,3-dichloropropane","range":"(0,040 - 10,0) mg/kg"},{"name":"2,2-dichloropropane","range":"(0,040 - 10,0) mg/kg"},{"name":"1,2,3-trichloropropane","range":"(0,040 - 10,0) mg/kg"},{"name":"1,2-dibromo-3-chloropropane","range":"(0,040 - 10,0) mg/kg"},{"name":"1,1-dichloropropene","range":"(0,040 - 10,0) mg/kg"},{"name":"cis-1,3-dichloropropene","range":"(0,040 - 10,0) mg/kg"},{"name":"trans-1,3-dichloropropene","range":"(0,040 - 10,0) mg/kg"},{"name":"hexachlorobutadiene","range":"(0,020 - 10,0) mg/kg"},{"name":"vinyl chloride","range":"(0,010 - 20,0) mg/kg"},{"name":"chloroethane","range":"(0,010 - 20,0) mg/kg"},{"name":"chlorobenzene","range":"(0,010 - 20,0) mg/kg"},{"name":"bromobenzene","range":"(0,020 - 10,0) mg/kg"},{"name":"1,2-dichlorobenzene","range":"(0,010 - 20,0) mg/kg"},{"name":"1,3-dichlorobenzene","range":"(0,010 - 20,0) mg/kg"},{"name":"1,4-dichlorobenzene","range":"(0,010 - 20,0) mg/kg"},{"name":"1,2,3-trichlorobenzene","range":"(0,010 - 20,0) mg/kg"},{"name":"1,2,4-Trichlorobenzene","range":"(0,010 - 20,0) mg/kg"}],"search_en":"Soil Volatile compound content Headspace gas chromatography with mass spectrometry detection (HS-GC-MS) benzene toluene ethylbenzene o-xylene (m+p)-xylene styrene naphthalene dichloromethane dibromomethane trichloromethane tribromomethane dibromochloromethane bromodichloromethane tetrachloromethane Range 1,2-dichloroethane bromochloromethane 1,2-dibromoethane cis-1,2-dichloroethene trans-1,2-dichloroethene 1,1-dichloroethene 1,1,1-trichloroethane 1,1,2-trichloroethane trichloroethene tetrachloroethene 1,1,1,2-tetrachloroethane 1,1,2,2-tetrachloroethane 1,2-dichloropropane 1,3-dichloropropane 2,2-dichloropropane 1,2,3-trichloropropane 1,2-dibromo-3-chloropropane 1,1-dichloropropene cis-1,3-dichloropropene trans-1,3-dichloropropene hexachlorobutadiene vinyl chloride chloroethane chlorobenzene bromobenzene 1,2-dichlorobenzene 1,3-dichlorobenzene 1,4-dichlorobenzene 1,2,3-trichlorobenzene 1,2,4-Trichlorobenzene PN-EN ISO 22155:2016-07","technique_en":"Headspace gas chromatography with mass spectrometry detection (HS-GC-MS)","test_object_en":"Soil","parameters_zh":[{"name":"苯","range":"(0,020 - 250) mg/kg"},{"name":"甲苯","range":"(0,020 - 250) mg/kg"},{"name":"乙苯","range":"(0,020 - 250) mg/kg"},{"name":"邻二甲苯","range":"(0,020 - 250) mg/kg"},{"name":"(间+对)-二甲苯","range":"(0,040 - 500) mg/kg"},{"name":"苯乙烯","range":"(0,020 - 250) mg/kg"},{"name":"萘","range":"(0,040 - 10,0) mg/kg"},{"name":"二氯甲烷","range":"(0,010 - 20,0) mg/kg"},{"name":"二溴甲烷","range":"(0,020 - 10,0) mg/kg"},{"name":"三氯甲烷","range":"(0,010 - 20,0) mg/kg"},{"name":"三溴甲烷","range":"(0,020 - 10,0) mg/kg"},{"name":"二溴一氯甲烷","range":"(0,020 - 10,0) mg/kg"},{"name":"一溴二氯甲烷","range":"(0,020 - 10,0) mg/kg"},{"name":"四氯化碳","range":"(0,010 - 20,0) mg/kg"},{"name":"范围","range":"1,1-dichloroetan (0,020 - 10,0) mg/kg"},{"name":"1,2-二氯乙烷","range":"(0,010 - 20,0) mg/kg"},{"name":"溴氯甲烷","range":"(0,020 - 10,0) mg/kg"},{"name":"1,2-二溴乙烷","range":"(0,020 - 10,0) mg/kg"},{"name":"顺式-1,2-二氯乙烯","range":"(0,010 - 10,0) mg/kg"},{"name":"反式-1,2-二氯乙烯","range":"(0,010 - 10,0) mg/kg"},{"name":"1,1-二氯乙烯","range":"(0,010 - 10,0) mg/kg"},{"name":"1,1,1-三氯乙烷","range":"(0,020 - 10,0) mg/kg"},{"name":"1,1,2-三氯乙烷","range":"(0,010 - 20,0) mg/kg"},{"name":"三氯乙烯","range":"(0,010 - 10,0) mg/kg"},{"name":"四氯乙烯","range":"(0,010 - 10,0) mg/kg"},{"name":"1,1,1,2-四氯乙烷","range":"(0,020 - 10,0) mg/kg"},{"name":"1,1,2,2-四氯乙烷","range":"(0,010 - 20,0) mg/kg"},{"name":"1,2-二氯丙烷","range":"(0,040 - 10,0) mg/kg"},{"name":"1,3-二氯丙烷","range":"(0,040 - 10,0) mg/kg"},{"name":"2,2-二氯丙烷","range":"(0,040 - 10,0) mg/kg"},{"name":"1,2,3-三氯丙烷","range":"(0,040 - 10,0) mg/kg"},{"name":"1,2-二溴-3-氯丙烷","range":"(0,040 - 10,0) mg/kg"},{"name":"1,1-二氯丙烯","range":"(0,040 - 10,0) mg/kg"},{"name":"顺式-1,3-二氯丙烯","range":"(0,040 - 10,0) mg/kg"},{"name":"反式-1,3-二氯丙烯","range":"(0,040 - 10,0) mg/kg"},{"name":"六氯丁二烯","range":"(0,020 - 10,0) mg/kg"},{"name":"氯乙烯","range":"(0,010 - 20,0) mg/kg"},{"name":"氯乙烷","range":"(0,010 - 20,0) mg/kg"},{"name":"氯苯","range":"(0,010 - 20,0) mg/kg"},{"name":"溴苯","range":"(0,020 - 10,0) mg/kg"},{"name":"1,2-二氯苯","range":"(0,010 - 20,0) mg/kg"},{"name":"1,3-二氯苯","range":"(0,010 - 20,0) mg/kg"},{"name":"1,4-二氯苯","range":"(0,010 - 20,0) mg/kg"},{"name":"1,2,3-三氯苯","range":"(0,010 - 20,0) mg/kg"},{"name":"1,2,4-三氯苯","range":"(0,010 - 20,0) mg/kg"}],"search_zh":"土壤 顶空气相色谱-质谱法（HS-GC-MS） 苯 甲苯 乙苯 邻二甲苯 (间+对)-二甲苯 苯乙烯 萘 二氯甲烷 二溴甲烷 三氯甲烷 三溴甲烷 二溴一氯甲烷 一溴二氯甲烷 四氯化碳 范围 1,2-二氯乙烷 溴氯甲烷 1,2-二溴乙烷 顺式-1,2-二氯乙烯 反式-1,2-二氯乙烯 1,1-二氯乙烯 1,1,1-三氯乙烷 1,1,2-三氯乙烷 三氯乙烯 四氯乙烯 1,1,1,2-四氯乙烷 1,1,2,2-四氯乙烷 1,2-二氯丙烷 1,3-二氯丙烷 2,2-二氯丙烷 1,2,3-三氯丙烷 1,2-二溴-3-氯丙烷 1,1-二氯丙烯 顺式-1,3-二氯丙烯 反式-1,3-二氯丙烯 六氯丁二烯 氯乙烯 氯乙烷 氯苯 溴苯 1,2-二氯苯 1,3-二氯苯 1,4-二氯苯 1,2,3-三氯苯 1,2,4-三氯苯 PN-EN ISO 22155:2016-07","test_object_zh":"土壤","technique_zh":"顶空气相色谱-质谱法（HS-GC-MS）"},{"_id":"6a8369ecaf14b9c0e7b1de3f","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość związków lotnych","parameters":[{"name":"Zakres","range":"1,3,5-Trichlorobenzen (0,010 - 20,0) mg/kg"},{"name":"n-Butylobenzen","range":"(0,020 - 10,0) mg/kg"},{"name":"sec-Butylobenzen","range":"(0,020 - 10,0) mg/kg"},{"name":"tert-Butylobenzen","range":"(0,020 - 10,0) mg/kg"},{"name":"Izopropylobenzen","range":"(0,020 - 10,0) mg/kg"},{"name":"n-Propylobenzen","range":"(0,020 - 10,0) mg/kg"},{"name":"2-Chlorotoluen","range":"(0,020 - 10,0) mg/kg"},{"name":"4-Chlorotoluen","range":"(0,020 - 10,0) mg/kg"},{"name":"4-Izopropylotoluen","range":"(0,020 - 10,0) mg/kg"},{"name":"1,3,5-Trimetylobenzen","range":"(0,020 - 10) mg/kg"},{"name":"3-Metylopentan","range":"(0,040 - 10,0) mg/kg"},{"name":"2,2,4-Trimetylopentan","range":"(0,020 - 250) g/kg"},{"name":"1,2,4-Trimetylobenzen","range":"(0,020 - 250) mg/kg"},{"name":"eter metylowo-tert-butylowy (MTBE)","range":"(0,040 - 10,0) mg/kg"},{"name":"eter metylowo-tert-amylowy (TAME)","range":"(0,040 - 10,0) mg/kg"},{"name":"eter etylowo-tert-amylowy (TAEE)","range":"(0,040 - 10,0) mg/kg"},{"name":"eter etylowo-tert-butylowy (ETBE)","range":"(0,040 - 10,0) mg/kg"},{"name":"n-heksan","range":"(0,040 - 250) mg/kg"},{"name":"n-heptan","range":"(0,040 - 250) mg/kg"},{"name":"n-oktan","range":"(0,040 - 250) mg/kg"},{"name":"n-nonan","range":"(0,040 - 250) mg/kg"},{"name":"n-dekan","range":"(0,040 - 250) mg/kg"},{"name":"n-undekan","range":"(0,040 - 250) mg/kg"},{"name":"n-dodekan","range":"(0,040 - 250) mg/kg"},{"name":"Suma benzyn (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)","techniques":["Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)"],"computed":[],"activity":"Zawartość związków lotnych\nZakres:\nZakres 1,3,5-Trichlorobenzen (0,010 - 20,0) mg/kg\nn-Butylobenzen (0,020 - 10,0) mg/kg\nsec-Butylobenzen (0,020 - 10,0) mg/kg\ntert-Butylobenzen (0,020 - 10,0) mg/kg\nIzopropylobenzen (0,020 - 10,0) mg/kg\nn-Propylobenzen (0,020 - 10,0) mg/kg\n2-Chlorotoluen (0,020 - 10,0) mg/kg\n4-Chlorotoluen (0,020 - 10,0) mg/kg\n4-Izopropylotoluen (0,020 - 10,0) mg/kg\n1,3,5-Trimetylobenzen (0,020 - 10) mg/kg\n3-Metylopentan (0,040 - 10,0) mg/kg\n2,2,4-Trimetylopentan (0,020 - 250) g/kg\n1,2,4-Trimetylobenzen (0,020 - 250) mg/kg\neter metylowo-tert-butylowy (MTBE) (0,040 - 10,0) mg/kg\neter metylowo-tert-amylowy (TAME) (0,040 - 10,0) mg/kg\neter etylowo-tert-amylowy (TAEE) (0,040 - 10,0) mg/kg\neter etylowo-tert-butylowy (ETBE) (0,040 - 10,0) mg/kg\nn-heksan (0,040 - 250) mg/kg\nn-heptan (0,040 - 250) mg/kg\nn-oktan (0,040 - 250) mg/kg\nn-nonan (0,040 - 250) mg/kg\nn-dekan (0,040 - 250) mg/kg\nn-undekan (0,040 - 250) mg/kg\nn-dodekan (0,040 - 250) mg/kg\nSuma benzyn (z obliczeń)\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)","reference":"PN-EN ISO 22155:2016-07","norm_bases":["PN-EN ISO 22155:2016-07"],"lab_section":"Pracownia Środowiskowa, Dział Analiz Organicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość związków lotnych\nZakres:\nZakres 1,3,5-Trichlorobenzen (0,010 - 20,0) mg/kg\nn-Butylobenzen (0,020 - 10,0) mg/kg\nsec-Butylobenzen (0,020 - 10,0) mg/kg\ntert-Butylobenzen (0,020 - 10,0) mg/kg\nIzopropylobenzen (0,020 - 10,0) mg/kg\nn-Propylobenzen (0,020 - 10,0) mg/kg\n2-Chlorotoluen (0,020 - 10,0) mg/kg\n4-Chlorotoluen (0,020 - 10,0) mg/kg\n4-Izopropylotoluen (0,020 - 10,0) mg/kg\n1,3,5-Trimetylobenzen (0,020 - 10) mg/kg\n3-Metylopentan (0,040 - 10,0) mg/kg\n2,2,4-Trimetylopentan (0,020 - 250) g/kg\n1,2,4-Trimetylobenzen (0,020 - 250) mg/kg\neter metylowo-tert-butylowy (MTBE) (0,040 - 10,0) mg/kg\neter metylowo-tert-amylowy (TAME) (0,040 - 10,0) mg/kg\neter etylowo-tert-amylowy (TAEE) (0,040 - 10,0) mg/kg\neter etylowo-tert-butylowy (ETBE) (0,040 - 10,0) mg/kg\nn-heksan (0,040 - 250) mg/kg\nn-heptan (0,040 - 250) mg/kg\nn-oktan (0,040 - 250) mg/kg\nn-nonan (0,040 - 250) mg/kg\nn-dekan (0,040 - 250) mg/kg\nn-undekan (0,040 - 250) mg/kg\nn-dodekan (0,040 - 250) mg/kg\nSuma benzyn (z obliczeń)\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS) PN-EN ISO 22155:2016-07 Gleba Zawartosc zwiazkow lotnych\nZakres:\nZakres 1,3,5-Trichlorobenzen (0,010 - 20,0) mg/kg\nn-Butylobenzen (0,020 - 10,0) mg/kg\nsec-Butylobenzen (0,020 - 10,0) mg/kg\ntert-Butylobenzen (0,020 - 10,0) mg/kg\nIzopropylobenzen (0,020 - 10,0) mg/kg\nn-Propylobenzen (0,020 - 10,0) mg/kg\n2-Chlorotoluen (0,020 - 10,0) mg/kg\n4-Chlorotoluen (0,020 - 10,0) mg/kg\n4-Izopropylotoluen (0,020 - 10,0) mg/kg\n1,3,5-Trimetylobenzen (0,020 - 10) mg/kg\n3-Metylopentan (0,040 - 10,0) mg/kg\n2,2,4-Trimetylopentan (0,020 - 250) g/kg\n1,2,4-Trimetylobenzen (0,020 - 250) mg/kg\neter metylowo-tert-butylowy (MTBE) (0,040 - 10,0) mg/kg\neter metylowo-tert-amylowy (TAME) (0,040 - 10,0) mg/kg\neter etylowo-tert-amylowy (TAEE) (0,040 - 10,0) mg/kg\neter etylowo-tert-butylowy (ETBE) (0,040 - 10,0) mg/kg\nn-heksan (0,040 - 250) mg/kg\nn-heptan (0,040 - 250) mg/kg\nn-oktan (0,040 - 250) mg/kg\nn-nonan (0,040 - 250) mg/kg\nn-dekan (0,040 - 250) mg/kg\nn-undekan (0,040 - 250) mg/kg\nn-dodekan (0,040 - 250) mg/kg\nSuma benzyn (z obliczen)\nMetoda chromatografii gazowej z analiza fazy nadpowierzchniowej i detekcja spektrometria mas (HS-GC-MS) PN-EN ISO 22155:2016-07","categories":["environment"],"row_index":541,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Volatile compound content","parameters_en":[{"name":"Range","range":"1,3,5-Trichlorobenzen (0,010 - 20,0) mg/kg"},{"name":"n-Butylbenzene","range":"(0,020 - 10,0) mg/kg"},{"name":"sec-Butylbenzene","range":"(0,020 - 10,0) mg/kg"},{"name":"tert-Butylbenzene","range":"(0,020 - 10,0) mg/kg"},{"name":"Isopropylbenzene","range":"(0,020 - 10,0) mg/kg"},{"name":"n-Propylbenzene","range":"(0,020 - 10,0) mg/kg"},{"name":"2-Chlorotoluene","range":"(0,020 - 10,0) mg/kg"},{"name":"4-Chlorotoluene","range":"(0,020 - 10,0) mg/kg"},{"name":"4-Isopropyltoluene","range":"(0,020 - 10,0) mg/kg"},{"name":"1,3,5-Trimethylbenzene","range":"(0,020 - 10) mg/kg"},{"name":"3-Methylpentane","range":"(0,040 - 10,0) mg/kg"},{"name":"2,2,4-Trimethylpentane","range":"(0,020 - 250) g/kg"},{"name":"1,2,4-Trimethylbenzene","range":"(0,020 - 250) mg/kg"},{"name":"methyl tert-butyl ether (MTBE)","range":"(0,040 - 10,0) mg/kg"},{"name":"tert-amyl methyl ether (TAME)","range":"(0,040 - 10,0) mg/kg"},{"name":"tert-amyl ethyl ether (TAEE)","range":"(0,040 - 10,0) mg/kg"},{"name":"ethyl tert-butyl ether (ETBE)","range":"(0,040 - 10,0) mg/kg"},{"name":"n-hexane","range":"(0,040 - 250) mg/kg"},{"name":"n-heptane","range":"(0,040 - 250) mg/kg"},{"name":"n-octane","range":"(0,040 - 250) mg/kg"},{"name":"n-nonane","range":"(0,040 - 250) mg/kg"},{"name":"n-decane","range":"(0,040 - 250) mg/kg"},{"name":"n-undecane","range":"(0,040 - 250) mg/kg"},{"name":"n-dodecane","range":"(0,040 - 250) mg/kg"},{"name":"Sum of gasolines (calculated)"}],"search_en":"Soil Volatile compound content Headspace gas chromatography with mass spectrometry detection (HS-GC-MS) Range n-Butylbenzene sec-Butylbenzene tert-Butylbenzene Isopropylbenzene n-Propylbenzene 2-Chlorotoluene 4-Chlorotoluene 4-Isopropyltoluene 1,3,5-Trimethylbenzene 3-Methylpentane 2,2,4-Trimethylpentane 1,2,4-Trimethylbenzene methyl tert-butyl ether (MTBE) tert-amyl methyl ether (TAME) tert-amyl ethyl ether (TAEE) ethyl tert-butyl ether (ETBE) n-hexane n-heptane n-octane n-nonane n-decane n-undecane n-dodecane Sum of gasolines (calculated) PN-EN ISO 22155:2016-07","technique_en":"Headspace gas chromatography with mass spectrometry detection (HS-GC-MS)","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"1,3,5-Trichlorobenzen (0,010 - 20,0) mg/kg"},{"name":"n-Butylobenzen","range":"(0,020 - 10,0) mg/kg"},{"name":"sec-Butylobenzen","range":"(0,020 - 10,0) mg/kg"},{"name":"tert-Butylobenzen","range":"(0,020 - 10,0) mg/kg"},{"name":"Izopropylobenzen","range":"(0,020 - 10,0) mg/kg"},{"name":"n-Propylobenzen","range":"(0,020 - 10,0) mg/kg"},{"name":"2-Chlorotoluen","range":"(0,020 - 10,0) mg/kg"},{"name":"4-Chlorotoluen","range":"(0,020 - 10,0) mg/kg"},{"name":"4-Izopropylotoluen","range":"(0,020 - 10,0) mg/kg"},{"name":"1,3,5-Trimetylobenzen","range":"(0,020 - 10) mg/kg"},{"name":"3-Metylopentan","range":"(0,040 - 10,0) mg/kg"},{"name":"2,2,4-Trimetylopentan","range":"(0,020 - 250) g/kg"},{"name":"1,2,4-Trimetylobenzen","range":"(0,020 - 250) mg/kg"},{"name":"eter metylowo-tert-butylowy (MTBE)","range":"(0,040 - 10,0) mg/kg"},{"name":"eter metylowo-tert-amylowy (TAME)","range":"(0,040 - 10,0) mg/kg"},{"name":"eter etylowo-tert-amylowy (TAEE)","range":"(0,040 - 10,0) mg/kg"},{"name":"eter etylowo-tert-butylowy (ETBE)","range":"(0,040 - 10,0) mg/kg"},{"name":"正己烷","range":"(0,040 - 250) mg/kg"},{"name":"n-heptan","range":"(0,040 - 250) mg/kg"},{"name":"n-oktan","range":"(0,040 - 250) mg/kg"},{"name":"n-nonan","range":"(0,040 - 250) mg/kg"},{"name":"n-dekan","range":"(0,040 - 250) mg/kg"},{"name":"n-undekan","range":"(0,040 - 250) mg/kg"},{"name":"n-dodekan","range":"(0,040 - 250) mg/kg"},{"name":"Suma benzyn (z obliczeń)"}],"search_zh":"土壤 顶空气相色谱-质谱法（HS-GC-MS） 范围 正己烷 PN-EN ISO 22155:2016-07","test_object_zh":"土壤","technique_zh":"顶空气相色谱-质谱法（HS-GC-MS）"},{"_id":"6a8369ecaf14b9c0e7b1de40","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość fenolu i krezoli","parameters":[{"name":"fenol","range":"(0,050 - 100,0) mg/kg"},{"name":"o-krezol","range":"(0,050 - 100,0) mg/kg"},{"name":"m-krezol","range":"(0,050 - 100,0) mg/kg"},{"name":"p-krezol","range":"(0,050 - 100,0) mg/kg"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Zawartość fenolu i krezoli\nZakres:\nfenol (0,050 - 100,0) mg/kg\no-krezol (0,050 - 100,0) mg/kg\nm-krezol (0,050 - 100,0) mg/kg\np-krezol (0,050 - 100,0) mg/kg\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"PB-DAO-22 wersja 01 z dnia 23.02.2021 r.","norm_bases":["PB-DAO-22 wersja 01 z dnia 23.02.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Analiz Organicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość fenolu i krezoli\nZakres:\nfenol (0,050 - 100,0) mg/kg\no-krezol (0,050 - 100,0) mg/kg\nm-krezol (0,050 - 100,0) mg/kg\np-krezol (0,050 - 100,0) mg/kg\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) PB-DAO-22 wersja 01 z dnia 23.02.2021 r. Gleba Zawartosc fenolu i krezoli\nZakres:\nfenol (0,050 - 100,0) mg/kg\no-krezol (0,050 - 100,0) mg/kg\nm-krezol (0,050 - 100,0) mg/kg\np-krezol (0,050 - 100,0) mg/kg\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) PB-DAO-22 wersja 01 z dnia 23.02.2021 r.","categories":["environment"],"row_index":542,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phenol and cresol content","parameters_en":[{"name":"phenol","range":"(0,050 - 100,0) mg/kg"},{"name":"o-cresol","range":"(0,050 - 100,0) mg/kg"},{"name":"m-cresol","range":"(0,050 - 100,0) mg/kg"},{"name":"p-cresol","range":"(0,050 - 100,0) mg/kg"}],"search_en":"Soil Phenol and cresol content Gas chromatography with mass spectrometry detection (GC-MS) phenol o-cresol m-cresol p-cresol PB-DAO-22 wersja 01 z dnia 23.02.2021 r.","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","test_object_en":"Soil","search_zh":"土壤 气相色谱-质谱法（GC-MS） 苯酚 邻甲酚 PB-DAO-22 wersja 01 z dnia 23.02.2021 r.","technique_zh":"气相色谱-质谱法（GC-MS）","test_object_zh":"土壤","parameters_zh":[{"name":"苯酚","range":"(0,050 - 100,0) mg/kg"},{"name":"邻甲酚","range":"(0,050 - 100,0) mg/kg"},{"name":"m-krezol","range":"(0,050 - 100,0) mg/kg"},{"name":"p-krezol","range":"(0,050 - 100,0) mg/kg"}]},{"_id":"6a8369ecaf14b9c0e7b1de41","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Środowisko pracy – próbki powietrza pobrane na rurki z sorbentem","methodology":"Zawartość formaldehydu","parameters":[{"name":"Zakres","range":"(0,0005 - 0,100) mg w próbce"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)"],"computed":[],"activity":"Zawartość formaldehydu\nZakres (0,0005 - 0,100) mg w próbce\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","reference":"PB-DAO-02 wersja 01 z dnia 23.02.2021 r.","norm_bases":["PB-DAO-02 wersja 01 z dnia 23.02.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Analiz Organicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – próbki powietrza pobrane na rurki z sorbentem Zawartość formaldehydu\nZakres (0,0005 - 0,100) mg w próbce\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV) PB-DAO-02 wersja 01 z dnia 23.02.2021 r. Srodowisko pracy – probki powietrza pobrane na rurki z sorbentem Zawartosc formaldehydu\nZakres (0,0005 - 0,100) mg w probce\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC-UV) PB-DAO-02 wersja 01 z dnia 23.02.2021 r.","categories":["environment"],"row_index":543,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Formaldehyde content","parameters_en":[{"name":"Range","range":"(0,0005 - 0,100) mg w próbce"}],"search_en":"Workplace environment – air samples collected on sorbent tubes Formaldehyde content High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) Range PB-DAO-02 wersja 01 z dnia 23.02.2021 r.","technique_en":"High-performance liquid chromatography with spectrophotometric detection (HPLC-UV)","test_object_en":"Workplace environment – air samples collected on sorbent tubes","parameters_zh":[{"name":"范围","range":"(0,0005 - 0,100) mg w próbce"}],"search_zh":"工作环境 － 用吸附管采集的空气样品 甲醛含量 高效液相色谱-分光光度检测法（HPLC-UV） 范围 PB-DAO-02 wersja 01 z dnia 23.02.2021 r.","technique_zh":"高效液相色谱-分光光度检测法（HPLC-UV）","methodology_zh":"甲醛含量","test_object_zh":"工作环境 － 用吸附管采集的空气样品"},{"_id":"6a8369ecaf14b9c0e7b1de42","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody /wody","parameters":[{"name":"Zakres","range":"(4,0 - 80,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody /wody\nZakres (4,0 - 80,0) °C","reference":"PB-DPP-20 wersja 01 z dnia 21.01.2021 r. | PB-DPP-43 wersja 02 z dnia 01.03.2024 r.","norm_bases":["PB-DPP-20 wersja 01 z dnia 21.01.2021 r.","PB-DPP-43 wersja 02 z dnia 01.03.2024 r."],"lab_section":"Pracownia Środowiskowa, Dział Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody /wody\nZakres (4,0 - 80,0) °C PB-DPP-20 wersja 01 z dnia 21.01.2021 r. | PB-DPP-43 wersja 02 z dnia 01.03.2024 r. Woda na plywalniach Pobieranie probek do badan chemicznych i fizycznych Temperatura pobranej probki wody /wody\nZakres (4,0 - 80,0) °C PB-DPP-20 wersja 01 z dnia 21.01.2021 r. | PB-DPP-43 wersja 02 z dnia 01.03.2024 r.","categories":["water"],"row_index":544,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing Temperature of the collected water sample /water","parameters_en":[{"name":"Range","range":"(4,0 - 80,0) °C"}],"search_en":"Swimming pool water Sampling for chemical and physical testing Temperature of the collected water sample /water Range PB-DPP-20 wersja 01 z dnia 21.01.2021 r. | PB-DPP-43 wersja 02 z dnia 01.03.2024 r.","test_object_en":"Swimming pool water","parameters_zh":[{"name":"范围","range":"(4,0 - 80,0) °C"}],"search_zh":"游泳池水 范围 PB-DPP-20 wersja 01 z dnia 21.01.2021 r. | PB-DPP-43 wersja 02 z dnia 01.03.2024 r.","test_object_zh":"游泳池水"},{"_id":"6a8369ecaf14b9c0e7b1de43","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody /wody","parameters":[{"name":"Zakres","range":"(4,0 - 80,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody /wody\nZakres (4,0 - 80,0) °C","reference":"PN-ISO 5667-5:2017-10 z wyłączeniem p. 10.3 | PN-ISO 5667-4:2017-10 z wyłączeniem p.15,16 | PB-DPP-43 wersja 02 z dnia 01.03.2024 r.","norm_bases":["PN-ISO 5667-5:2017-10 z wyłączeniem p. 10.3","PN-ISO 5667-4:2017-10 z wyłączeniem p.15,16","PB-DPP-43 wersja 02 z dnia 01.03.2024 r."],"lab_section":"Pracownia Środowiskowa, Dział Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody /wody\nZakres (4,0 - 80,0) °C PN-ISO 5667-5:2017-10 z wyłączeniem p. 10.3 | PN-ISO 5667-4:2017-10 z wyłączeniem p.15,16 | PB-DPP-43 wersja 02 z dnia 01.03.2024 r. Woda Pobieranie probek do badan chemicznych i fizycznych Temperatura pobranej probki wody /wody\nZakres (4,0 - 80,0) °C PN-ISO 5667-5:2017-10 z wylaczeniem p. 10.3 | PN-ISO 5667-4:2017-10 z wylaczeniem p.15,16 | PB-DPP-43 wersja 02 z dnia 01.03.2024 r.","categories":["water"],"row_index":545,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing Temperature of the collected water sample /water","parameters_en":[{"name":"Range","range":"(4,0 - 80,0) °C"}],"search_en":"Water Sampling for chemical and physical testing Temperature of the collected water sample /water Range PN-ISO 5667-5:2017-10 z wyłączeniem p. 10.3 | PN-ISO 5667-4:2017-10 z wyłączeniem p.15,16 | PB-DPP-43 wersja 02 z dnia 01.03.2024 r.","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(4,0 - 80,0) °C"}],"search_zh":"水 范围 PN-ISO 5667-5:2017-10 z wyłączeniem p. 10.3 | PN-ISO 5667-4:2017-10 z wyłączeniem p.15,16 | PB-DPP-43 wersja 02 z dnia 01.03.2024 r.","test_object_zh":"水"},{"_id":"6a8369ecaf14b9c0e7b1de44","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody /wody","parameters":[{"name":"Zakres","range":"(4,0 - 80,0) °C"},{"name":"Wielkość przepływu"},{"name":"Zakres","range":"(0,01 - 2,00) m3/s"}],"technique":"Metoda pływakowa","techniques":["Metoda pływakowa"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody /wody\nZakres:\nZakres (4,0 - 80,0) °C\nWielkość przepływu\nZakres (0,01 - 2,00) m3/s\nMetoda pływakowa","reference":"PN-EN ISO 5667-6:2016-12 | PB-DPP-43 wersja 02 z dnia 01.03.2024 r. | PB-DPP-04 wersja 01 z dnia 21.01.2021 r.","norm_bases":["PN-EN ISO 5667-6:2016-12","PB-DPP-43 wersja 02 z dnia 01.03.2024 r.","PB-DPP-04 wersja 01 z dnia 21.01.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody /wody\nZakres:\nZakres (4,0 - 80,0) °C\nWielkość przepływu\nZakres (0,01 - 2,00) m3/s\nMetoda pływakowa PN-EN ISO 5667-6:2016-12 | PB-DPP-43 wersja 02 z dnia 01.03.2024 r. | PB-DPP-04 wersja 01 z dnia 21.01.2021 r. Woda Pobieranie probek do badan chemicznych i fizycznych Temperatura pobranej probki wody /wody\nZakres:\nZakres (4,0 - 80,0) °C\nWielkosc przeplywu\nZakres (0,01 - 2,00) m3/s\nMetoda plywakowa PN-EN ISO 5667-6:2016-12 | PB-DPP-43 wersja 02 z dnia 01.03.2024 r. | PB-DPP-04 wersja 01 z dnia 21.01.2021 r.","categories":["water"],"row_index":546,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing Temperature of the collected water sample /water","parameters_en":[{"name":"Range","range":"(4,0 - 80,0) °C"},{"name":"Flow rate"},{"name":"Range","range":"(0,01 - 2,00) m3/s"}],"search_en":"Water Sampling for chemical and physical testing Temperature of the collected water sample /water Float method Range Flow rate Range PN-EN ISO 5667-6:2016-12 | PB-DPP-43 wersja 02 z dnia 01.03.2024 r. | PB-DPP-04 wersja 01 z dnia 21.01.2021 r.","technique_en":"Float method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(4,0 - 80,0) °C"},{"name":"Wielkość przepływu"},{"name":"范围","range":"(0,01 - 2,00) m3/s"}],"search_zh":"水 范围 范围 PN-EN ISO 5667-6:2016-12 | PB-DPP-43 wersja 02 z dnia 01.03.2024 r. | PB-DPP-04 wersja 01 z dnia 21.01.2021 r.","test_object_zh":"水"},{"_id":"6a8369ecaf14b9c0e7b1de45","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda","methodology":"Pobieranie próbek do badań chemicznych, fizycznych Temperatura pobranej próbki wody /wody","parameters":[{"name":"Zakres","range":"(4,0 - 80,0) °C"},{"name":"Poziom zwierciadła wody"},{"name":"Zakres","range":"(0 - 50) m"}],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych, fizycznych Temperatura pobranej próbki wody /wody\nZakres:\nZakres (4,0 - 80,0) °C\nPoziom zwierciadła wody\nZakres (0 - 50) m","reference":"PN-ISO 5667-11:2017-10 z wyłączeniem p. 5.2, 6.1.2, 6.2, 6.3 | PB-DPP-43 wersja 02 z dnia 01.03.2024 r. | PB-DPP-02 wersja 01 z dnia 21.01.2021 r.","norm_bases":["PN-ISO 5667-11:2017-10 z wyłączeniem p. 5.2, 6.1.2, 6.2, 6.3","PB-DPP-43 wersja 02 z dnia 01.03.2024 r.","PB-DPP-02 wersja 01 z dnia 21.01.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Pobieranie próbek do badań chemicznych, fizycznych Temperatura pobranej próbki wody /wody\nZakres:\nZakres (4,0 - 80,0) °C\nPoziom zwierciadła wody\nZakres (0 - 50) m PN-ISO 5667-11:2017-10 z wyłączeniem p. 5.2, 6.1.2, 6.2, 6.3 | PB-DPP-43 wersja 02 z dnia 01.03.2024 r. | PB-DPP-02 wersja 01 z dnia 21.01.2021 r. Woda Pobieranie probek do badan chemicznych, fizycznych Temperatura pobranej probki wody /wody\nZakres:\nZakres (4,0 - 80,0) °C\nPoziom zwierciadla wody\nZakres (0 - 50) m PN-ISO 5667-11:2017-10 z wylaczeniem p. 5.2, 6.1.2, 6.2, 6.3 | PB-DPP-43 wersja 02 z dnia 01.03.2024 r. | PB-DPP-02 wersja 01 z dnia 21.01.2021 r.","categories":["water"],"row_index":547,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical, physical testing Temperature of the water sample taken /of water","parameters_en":[{"name":"Range","range":"(4,0 - 80,0) °C"},{"name":"Poziom zwierciadła wody"},{"name":"Range","range":"(0 - 50) m"}],"search_en":"Water Sampling for chemical, physical testing Temperature of the water sample taken /of water Range Range PN-ISO 5667-11:2017-10 z wyłączeniem p. 5.2, 6.1.2, 6.2, 6.3 | PB-DPP-43 wersja 02 z dnia 01.03.2024 r. | PB-DPP-02 wersja 01 z dnia 21.01.2021 r.","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(4,0 - 80,0) °C"},{"name":"Poziom zwierciadła wody"},{"name":"范围","range":"(0 - 50) m"}],"search_zh":"水 范围 范围 PN-ISO 5667-11:2017-10 z wyłączeniem p. 5.2, 6.1.2, 6.2, 6.3 | PB-DPP-43 wersja 02 z dnia 01.03.2024 r. | PB-DPP-02 wersja 01 z dnia 21.01.2021 r.","test_object_zh":"水"},{"_id":"6a8369ecaf14b9c0e7b1de46","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007","norm_bases":["PN-EN ISO 19458:2007"],"lab_section":"Pracownia Środowiskowa, Dział Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 Woda (w tym woda na plywalniach), Woda do spozycia przez ludzi Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007","categories":["water","microbiology"],"row_index":548,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for microbiological testing","search_en":"Water (including swimming pool water), Water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007","test_object_en":"Water (including swimming pool water), Water intended for human consumption","methodology_zh":"微生物检测用样品采集","search_zh":"水（含游泳池水）、生活饮用水 微生物检测用样品采集 PN-EN ISO 19458:2007","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a8369ecaf14b9c0e7b1de47","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Gleba użytkowana rolniczo","methodology":"Pobieranie próbek do badań chemicznych, fizycznych i mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych, fizycznych i mikrobiologicznych","reference":"PN-R-04031:1997 | PN-ISO 10381-4:2007","norm_bases":["PN-R-04031:1997","PN-ISO 10381-4:2007"],"lab_section":"Pracownia Środowiskowa, Dział Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba użytkowana rolniczo Pobieranie próbek do badań chemicznych, fizycznych i mikrobiologicznych PN-R-04031:1997 | PN-ISO 10381-4:2007 Gleba uzytkowana rolniczo Pobieranie probek do badan chemicznych, fizycznych i mikrobiologicznych PN-R-04031:1997 | PN-ISO 10381-4:2007","categories":["environment","microbiology"],"row_index":549,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical, physical and microbiological testing","search_en":"Agriculturally used soil Sampling for chemical, physical and microbiological testing PN-R-04031:1997 | PN-ISO 10381-4:2007","test_object_en":"Agriculturally used soil","methodology_zh":"用于化学、物理与微生物检验的采样","search_zh":"用于化学、物理与微生物检验的采样 PN-R-04031:1997 | PN-ISO 10381-4:2007"},{"_id":"6a8369ecaf14b9c0e7b1de48","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Gleba","methodology":"Pobieranie próbek do badań chemicznych, fizycznych i badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych, fizycznych i badań mikrobiologicznych","reference":"PN-ISO 10381-5:2009","norm_bases":["PN-ISO 10381-5:2009"],"lab_section":"Pracownia Środowiskowa, Dział Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Pobieranie próbek do badań chemicznych, fizycznych i badań mikrobiologicznych PN-ISO 10381-5:2009 Gleba Pobieranie probek do badan chemicznych, fizycznych i badan mikrobiologicznych PN-ISO 10381-5:2009","categories":["environment","microbiology"],"row_index":550,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical, physical and microbiological testing","search_en":"Soil Sampling for chemical, physical and microbiological testing PN-ISO 10381-5:2009","test_object_en":"Soil","search_zh":"土壤 PN-ISO 10381-5:2009","test_object_zh":"土壤"},{"_id":"6a8369ecaf14b9c0e7b1de49","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[{"name":"Temperatura pobranej próbki ścieków / ścieków"},{"name":"Zakres","range":"(4,0 - 80,0) °C"}],"technique":"Metoda manualna; Metoda automatyczna","techniques":["Metoda manualna","Metoda automatyczna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura pobranej próbki ścieków / ścieków\nZakres (4,0 - 80,0) °C\nMetoda manualna; Metoda automatyczna","reference":"PN-ISO 5667-10:2021-11 | PB-DPP-43 wersja 02 z dnia 01.03.2024 r.","norm_bases":["PN-ISO 5667-10:2021-11","PB-DPP-43 wersja 02 z dnia 01.03.2024 r."],"lab_section":"Pracownia Środowiskowa, Dział Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura pobranej próbki ścieków / ścieków\nZakres (4,0 - 80,0) °C\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 | PB-DPP-43 wersja 02 z dnia 01.03.2024 r. Scieki Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nTemperatura pobranej probki sciekow / sciekow\nZakres (4,0 - 80,0) °C\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 | PB-DPP-43 wersja 02 z dnia 01.03.2024 r.","categories":["water"],"row_index":551,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","parameters_en":[{"name":"Temperature of the collected wastewater sample / wastewater"},{"name":"Range","range":"(4,0 - 80,0) °C"}],"search_en":"Wastewater Sampling for chemical and physical testing Manual method; Automatic method Temperature of the collected wastewater sample / wastewater Range PN-ISO 5667-10:2021-11 | PB-DPP-43 wersja 02 z dnia 01.03.2024 r.","technique_en":"Manual method; Automatic method","test_object_en":"Wastewater","methodology_zh":"化学与物理检测用样品采集","parameters_zh":[{"name":"Temperatura pobranej próbki ścieków / ścieków"},{"name":"范围","range":"(4,0 - 80,0) °C"}],"search_zh":"污水 化学与物理检测用样品采集 手动法；自动法 范围 PN-ISO 5667-10:2021-11 | PB-DPP-43 wersja 02 z dnia 01.03.2024 r.","technique_zh":"手动法；自动法","test_object_zh":"污水"},{"_id":"6a8369ecaf14b9c0e7b1de4a","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Kompost, Biomasa","methodology":"Pobieranie próbek do badań chemicznych, fizycznych i badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych, fizycznych i badań mikrobiologicznych","reference":"PB-DPP-05 wersja 01 Z dnia 21.01.2021 r.","norm_bases":["PB-DPP-05 wersja 01 Z dnia 21.01.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kompost, Biomasa Pobieranie próbek do badań chemicznych, fizycznych i badań mikrobiologicznych PB-DPP-05 wersja 01 Z dnia 21.01.2021 r. Kompost, Biomasa Pobieranie probek do badan chemicznych, fizycznych i badan mikrobiologicznych PB-DPP-05 wersja 01 Z dnia 21.01.2021 r.","categories":["microbiology"],"row_index":552,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical, physical and microbiological testing","search_en":"Compost, Biomass Sampling for chemical, physical and microbiological testing PB-DPP-05 wersja 01 Z dnia 21.01.2021 r.","test_object_en":"Compost, Biomass"},{"_id":"6a8369ecaf14b9c0e7b1de4b","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Stabilizat","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-Z-15011-1:1998","norm_bases":["PN-Z-15011-1:1998"],"lab_section":"Pracownia Środowiskowa, Dział Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Stabilizat Pobieranie próbek do badań chemicznych i fizycznych PN-Z-15011-1:1998 Stabilizat Pobieranie probek do badan chemicznych i fizycznych PN-Z-15011-1:1998","categories":["other"],"row_index":553,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Stabilised waste Sampling for chemical and physical testing PN-Z-15011-1:1998","test_object_en":"Stabilised waste","methodology_zh":"化学与物理检测用样品采集","search_zh":"稳定化产物 化学与物理检测用样品采集 PN-Z-15011-1:1998","test_object_zh":"稳定化产物"},{"_id":"6a8369ecaf14b9c0e7b1de4c","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Powierzchnie systemów wentylacyjnych","methodology":"Pobieranie próbek z powierzchni","parameters":[],"technique":"Metoda wymazów; Metoda płytek kontaktowych","techniques":["Metoda wymazów","Metoda płytek kontaktowych"],"computed":[],"activity":"Pobieranie próbek z powierzchni\nMetoda wymazów; Metoda płytek kontaktowych","reference":"PN-EN ISO 18593:2018-08","norm_bases":["PN-EN ISO 18593:2018-08"],"lab_section":"Pracownia Środowiskowa, Dział Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Powierzchnie systemów wentylacyjnych Pobieranie próbek z powierzchni\nMetoda wymazów; Metoda płytek kontaktowych PN-EN ISO 18593:2018-08 Powierzchnie systemow wentylacyjnych Pobieranie probek z powierzchni\nMetoda wymazow; Metoda plytek kontaktowych PN-EN ISO 18593:2018-08","categories":["other"],"row_index":554,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Surface sampling","search_en":"Surfaces of ventilation systems Surface sampling Swab method; Contact plate method PN-EN ISO 18593:2018-08","technique_en":"Swab method; Contact plate method","test_object_en":"Surfaces of ventilation systems"},{"_id":"6a8369ecaf14b9c0e7b1de4d","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością: - wymaz - odcisk z powierzchni","methodology":"Pobieranie próbek z powierzchni do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek z powierzchni do badań mikrobiologicznych","reference":"PN-EN ISO 18593:2018-08","norm_bases":["PN-EN ISO 18593:2018-08"],"lab_section":"Pracownia Środowiskowa, Dział Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Próbki środowiskowe z obszarów produkcji żywności i obrotu żywnością: - wymaz - odcisk z powierzchni Pobieranie próbek z powierzchni do badań mikrobiologicznych PN-EN ISO 18593:2018-08 Probki srodowiskowe z obszarow produkcji zywnosci i obrotu zywnoscia: - wymaz - odcisk z powierzchni Pobieranie probek z powierzchni do badan mikrobiologicznych PN-EN ISO 18593:2018-08","categories":["food","environment","microbiology"],"row_index":555,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Surface sampling for microbiological testing","search_en":"Environmental samples from food production and distribution areas: - swab - surface imprint Surface sampling for microbiological testing PN-EN ISO 18593:2018-08","test_object_en":"Environmental samples from food production and distribution areas: - swab - surface imprint","methodology_zh":"微生物检测用表面样品采集","search_zh":"微生物检测用表面样品采集 PN-EN ISO 18593:2018-08"},{"_id":"6a8369ecaf14b9c0e7b1de4e","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby, - stymulatory wzrostu, - podłoża do upraw","methodology":"Pobieranie próbek do badań chemicznych, fizycznych, mikrobiologicznych i parazytologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych, fizycznych, mikrobiologicznych i parazytologicznych","reference":"PN-EN 12579:2013-12","norm_bases":["PN-EN 12579:2013-12"],"lab_section":"Pracownia Środowiskowa, Dział Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby, - stymulatory wzrostu, - podłoża do upraw Pobieranie próbek do badań chemicznych, fizycznych, mikrobiologicznych i parazytologicznych PN-EN 12579:2013-12 Srodki wspomagajace uprawe roslin: - srodki poprawiajace wlasciwosci gleby, - stymulatory wzrostu, - podloza do upraw Pobieranie probek do badan chemicznych, fizycznych, mikrobiologicznych i parazytologicznych PN-EN 12579:2013-12","categories":["microbiology"],"row_index":556,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical, physical, microbiological and parasitological testing","search_en":"Plant cultivation aids: - soil improvers, - growth stimulants, - growing media Sampling for chemical, physical, microbiological and parasitological testing PN-EN 12579:2013-12","test_object_en":"Plant cultivation aids: - soil improvers, - growth stimulants, - growing media","methodology_zh":"用于化学、物理、微生物与寄生虫学检验的采样","search_zh":"用于化学、物理、微生物与寄生虫学检验的采样 PN-EN 12579:2013-12"},{"_id":"6a8369ecaf14b9c0e7b1de4f","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda (w tym, woda na pływalniach), Ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 - 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 - 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Pracownia Środowiskowa, Dział Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym, woda na pływalniach), Ścieki pH\nZakres 4,0 - 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda (w tym, woda na plywalniach), Scieki pH\nZakres 4,0 - 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":557,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 - 10,0"}],"search_en":"Water (including, swimming pool water), Wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water (including, swimming pool water), Wastewater","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 - 10,0"}],"search_zh":"水（含游泳池水）、废水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水（含游泳池水）、废水"},{"_id":"6a8369ecaf14b9c0e7b1de50","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(100 - 25000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (100 - 25000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Pracownia Środowiskowa, Dział Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Przewodność elektryczna właściwa\nZakres (100 - 25000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, Scieki Przewodnosc elektryczna wlasciwa\nZakres (100 - 25000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":558,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(100 - 25000) μS/cm"}],"search_en":"Water, Wastewater Electrical conductivity Conductometric method Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water, Wastewater","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(100 - 25000) μS/cm"}],"search_zh":"水、污水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、污水"},{"_id":"6a8369ecaf14b9c0e7b1de51","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie tlenu rozpuszczonego","parameters":[{"name":"Zakres","range":"0,5 - 15,0 mg/l O2"},{"name":"5,0 - 140 % nasycenia O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Stężenie tlenu rozpuszczonego\nZakres:\nZakres 0,5 - 15,0 mg/l O2\n5,0 - 140 % nasycenia O2\nMetoda optyczna","reference":"PB-DPP-42 wersja 01 z dnia 21.01.2021 r.","norm_bases":["PB-DPP-42 wersja 01 z dnia 21.01.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie tlenu rozpuszczonego\nZakres:\nZakres 0,5 - 15,0 mg/l O2\n5,0 - 140 % nasycenia O2\nMetoda optyczna PB-DPP-42 wersja 01 z dnia 21.01.2021 r. Woda, Scieki Stezenie tlenu rozpuszczonego\nZakres:\nZakres 0,5 - 15,0 mg/l O2\n5,0 - 140 % nasycenia O2\nMetoda optyczna PB-DPP-42 wersja 01 z dnia 21.01.2021 r.","categories":["water"],"row_index":559,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissolved oxygen concentration","parameters_en":[{"name":"Range","range":"0,5 - 15,0 mg/l O2"},{"name":"5,0 - 140 % O2 saturation"}],"search_en":"Water, Wastewater Dissolved oxygen concentration Optical method Range 5,0 - 140 % O2 saturation PB-DPP-42 wersja 01 z dnia 21.01.2021 r.","technique_en":"Optical method","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"0,5 - 15,0 mg/l O2"},{"name":"5,0 - 140 % nasycenia O2"}],"search_zh":"水、污水 溶解氧浓度 光学法 范围 PB-DPP-42 wersja 01 z dnia 21.01.2021 r.","technique_zh":"光学法","test_object_zh":"水、污水","methodology_zh":"溶解氧浓度"},{"_id":"6a8369ecaf14b9c0e7b1de52","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie chloru wolnego","parameters":[{"name":"Zakres","range":"(0,05 - 2,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chloru wolnego\nZakres (0,05 - 2,00) mg/l\nMetoda spektrofotometryczna","reference":"PB-DPP-27 wersja 01 z dnia 21.01.2021 r.","norm_bases":["PB-DPP-27 wersja 01 z dnia 21.01.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie chloru wolnego\nZakres (0,05 - 2,00) mg/l\nMetoda spektrofotometryczna PB-DPP-27 wersja 01 z dnia 21.01.2021 r. Scieki Stezenie chloru wolnego\nZakres (0,05 - 2,00) mg/l\nMetoda spektrofotometryczna PB-DPP-27 wersja 01 z dnia 21.01.2021 r.","categories":["water"],"row_index":560,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free chlorine concentration","parameters_en":[{"name":"Range","range":"(0,05 - 2,00) mg/l"}],"search_en":"Wastewater Free chlorine concentration Spectrophotometric method Range PB-DPP-27 wersja 01 z dnia 21.01.2021 r.","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"游离氯浓度","parameters_zh":[{"name":"范围","range":"(0,05 - 2,00) mg/l"}],"search_zh":"污水 游离氯浓度 分光光度法 范围 PB-DPP-27 wersja 01 z dnia 21.01.2021 r.","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a8369ecaf14b9c0e7b1de53","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda (w tym, woda na pływalniach)","methodology":"Stężenie ozonu","parameters":[{"name":"Zakres","range":"(0,01 - 0,75) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie ozonu\nZakres (0,01 - 0,75) mg/l\nMetoda spektrofotometryczna","reference":"PB-DPP-53 wersja 01 z dnia 21.01.2021 r.","norm_bases":["PB-DPP-53 wersja 01 z dnia 21.01.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym, woda na pływalniach) Stężenie ozonu\nZakres (0,01 - 0,75) mg/l\nMetoda spektrofotometryczna PB-DPP-53 wersja 01 z dnia 21.01.2021 r. Woda (w tym, woda na plywalniach) Stezenie ozonu\nZakres (0,01 - 0,75) mg/l\nMetoda spektrofotometryczna PB-DPP-53 wersja 01 z dnia 21.01.2021 r.","categories":["water"],"row_index":561,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ozone concentration","parameters_en":[{"name":"Range","range":"(0,01 - 0,75) mg/l"}],"search_en":"Water (including, swimming pool water) Ozone concentration Spectrophotometric method Range PB-DPP-53 wersja 01 z dnia 21.01.2021 r.","technique_en":"Spectrophotometric method","test_object_en":"Water (including, swimming pool water)","parameters_zh":[{"name":"范围","range":"(0,01 - 0,75) mg/l"}],"search_zh":"水（含游泳池水） 臭氧浓度 分光光度法 范围 PB-DPP-53 wersja 01 z dnia 21.01.2021 r.","technique_zh":"分光光度法","methodology_zh":"臭氧浓度","test_object_zh":"水（含游泳池水）"},{"_id":"6a8369ecaf14b9c0e7b1de54","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda (w tym, woda na pływalniach)","methodology":"Potencjał utleniająco-redukujący (redox) wzgl. Ag/AgCl 3,5 mol/l KCl","parameters":[{"name":"Zakres","range":"(-500 - 1000) mV"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"Potencjał utleniająco-redukujący (redox) wzgl. Ag/AgCl 3,5 mol/l KCl\nZakres (-500 - 1000) mV\nMetoda potencjometryczna","reference":"PB-DPP-49 wersja 01 z dnia 21.01.2021 r.","norm_bases":["PB-DPP-49 wersja 01 z dnia 21.01.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym, woda na pływalniach) Potencjał utleniająco-redukujący (redox) wzgl. Ag/AgCl 3,5 mol/l KCl\nZakres (-500 - 1000) mV\nMetoda potencjometryczna PB-DPP-49 wersja 01 z dnia 21.01.2021 r. Woda (w tym, woda na plywalniach) Potencjal utleniajaco-redukujacy (redox) wzgl. Ag/AgCl 3,5 mol/l KCl\nZakres (-500 - 1000) mV\nMetoda potencjometryczna PB-DPP-49 wersja 01 z dnia 21.01.2021 r.","categories":["water"],"row_index":562,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Oxidation-reduction potential (redox) vs. Ag/AgCl 3,5 mol/l KCl","parameters_en":[{"name":"Range","range":"(-500 - 1000) mV"}],"search_en":"Water (including, swimming pool water) Oxidation-reduction potential (redox) vs. Ag/AgCl 3,5 mol/l KCl Potentiometric method Range PB-DPP-49 wersja 01 z dnia 21.01.2021 r.","technique_en":"Potentiometric method","test_object_en":"Water (including, swimming pool water)","parameters_zh":[{"name":"范围","range":"(-500 - 1000) mV"}],"search_zh":"水（含游泳池水） 氧化还原电位（redox），相对于 Ag/AgCl 3,5 mol/l KCl 电位法 范围 PB-DPP-49 wersja 01 z dnia 21.01.2021 r.","technique_zh":"电位法","test_object_zh":"水（含游泳池水）","methodology_zh":"氧化还原电位（redox），相对于 Ag/AgCl 3,5 mol/l KCl"},{"_id":"6a8369ecaf14b9c0e7b1de55","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda (w tym, woda na pływalniach)","methodology":"Stężenie chloru ogólnego (całkowitego)","parameters":[{"name":"Zakres","range":"(0,05 - 2,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chloru ogólnego (całkowitego)\nZakres (0,05 - 2,00) mg/l\nMetoda spektrofotometryczna","reference":"PB-DPP-27 wersja 01 z dnia 21.01.2021 r.","norm_bases":["PB-DPP-27 wersja 01 z dnia 21.01.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym, woda na pływalniach) Stężenie chloru ogólnego (całkowitego)\nZakres (0,05 - 2,00) mg/l\nMetoda spektrofotometryczna PB-DPP-27 wersja 01 z dnia 21.01.2021 r. Woda (w tym, woda na plywalniach) Stezenie chloru ogolnego (calkowitego)\nZakres (0,05 - 2,00) mg/l\nMetoda spektrofotometryczna PB-DPP-27 wersja 01 z dnia 21.01.2021 r.","categories":["water"],"row_index":563,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total chlorine concentration","parameters_en":[{"name":"Range","range":"(0,05 - 2,00) mg/l"}],"search_en":"Water (including, swimming pool water) Total chlorine concentration Spectrophotometric method Range PB-DPP-27 wersja 01 z dnia 21.01.2021 r.","technique_en":"Spectrophotometric method","test_object_en":"Water (including, swimming pool water)","parameters_zh":[{"name":"范围","range":"(0,05 - 2,00) mg/l"}],"search_zh":"水（含游泳池水） 总氯浓度 分光光度法 范围 PB-DPP-27 wersja 01 z dnia 21.01.2021 r.","technique_zh":"分光光度法","test_object_zh":"水（含游泳池水）","methodology_zh":"总氯浓度"},{"_id":"6a8369ecaf14b9c0e7b1de56","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda (w tym, woda na pływalniach)","methodology":"Stężenie chloru związanego / chloramin (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie chloru związanego / chloramin (z obliczeń)","reference":"PB-DPP-27 wersja 01 z dnia 21.01.2021 r.","norm_bases":["PB-DPP-27 wersja 01 z dnia 21.01.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym, woda na pływalniach) Stężenie chloru związanego / chloramin (z obliczeń) PB-DPP-27 wersja 01 z dnia 21.01.2021 r. Woda (w tym, woda na plywalniach) Stezenie chloru zwiazanego / chloramin (z obliczen) PB-DPP-27 wersja 01 z dnia 21.01.2021 r.","categories":["water"],"row_index":564,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Combined chlorine / chloramine concentration (calculated)","search_en":"Water (including, swimming pool water) Combined chlorine / chloramine concentration (calculated) PB-DPP-27 wersja 01 z dnia 21.01.2021 r.","test_object_en":"Water (including, swimming pool water)","search_zh":"水（含游泳池水） PB-DPP-27 wersja 01 z dnia 21.01.2021 r.","test_object_zh":"水（含游泳池水）"},{"_id":"6a8369ecaf14b9c0e7b1de57","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Woda (w tym, woda na pływalniach)","methodology":"Stężenie chloru wolnego","parameters":[{"name":"Zakres","range":"(0,05 - 2,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chloru wolnego\nZakres (0,05 - 2,00) mg/l\nMetoda spektrofotometryczna","reference":"PB-DPP-27 wersja 01 z dnia 21.01.2021 r.","norm_bases":["PB-DPP-27 wersja 01 z dnia 21.01.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym, woda na pływalniach) Stężenie chloru wolnego\nZakres (0,05 - 2,00) mg/l\nMetoda spektrofotometryczna PB-DPP-27 wersja 01 z dnia 21.01.2021 r. Woda (w tym, woda na plywalniach) Stezenie chloru wolnego\nZakres (0,05 - 2,00) mg/l\nMetoda spektrofotometryczna PB-DPP-27 wersja 01 z dnia 21.01.2021 r.","categories":["water"],"row_index":565,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free chlorine concentration","parameters_en":[{"name":"Range","range":"(0,05 - 2,00) mg/l"}],"search_en":"Water (including, swimming pool water) Free chlorine concentration Spectrophotometric method Range PB-DPP-27 wersja 01 z dnia 21.01.2021 r.","technique_en":"Spectrophotometric method","test_object_en":"Water (including, swimming pool water)","methodology_zh":"游离氯浓度","parameters_zh":[{"name":"范围","range":"(0,05 - 2,00) mg/l"}],"search_zh":"水（含游泳池水） 游离氯浓度 分光光度法 范围 PB-DPP-27 wersja 01 z dnia 21.01.2021 r.","technique_zh":"分光光度法","test_object_zh":"水（含游泳池水）"},{"_id":"6a8369ecaf14b9c0e7b1de58","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Gazy składowiskowe","methodology":"Stężenie: dwutlenku węgla (CO2), metanu (CH4)","parameters":[{"name":"CO2","range":"(0,6 - 50) %"},{"name":"CH4","range":"(0,5 - 80) %"}],"technique":"Metoda absorpcji promieniowania IR","techniques":["Metoda absorpcji promieniowania IR"],"computed":[],"activity":"Stężenie: dwutlenku węgla (CO2), metanu (CH4)\nZakres:\nCO2 (0,6 - 50) %\nCH4 (0,5 - 80) %\nMetoda absorpcji promieniowania IR","reference":"PB-DPP-12 wersja 01 z dnia 21.01.2021 r.","norm_bases":["PB-DPP-12 wersja 01 z dnia 21.01.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy składowiskowe Stężenie: dwutlenku węgla (CO2), metanu (CH4)\nZakres:\nCO2 (0,6 - 50) %\nCH4 (0,5 - 80) %\nMetoda absorpcji promieniowania IR PB-DPP-12 wersja 01 z dnia 21.01.2021 r. Gazy skladowiskowe Stezenie: dwutlenku wegla (CO2), metanu (CH4)\nZakres:\nCO2 (0,6 - 50) %\nCH4 (0,5 - 80) %\nMetoda absorpcji promieniowania IR PB-DPP-12 wersja 01 z dnia 21.01.2021 r.","categories":["other"],"row_index":566,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of: carbon dioxide (CO2), methane (CH4)","parameters_en":[{"name":"CO2","range":"(0,6 - 50) %"},{"name":"CH4","range":"(0,5 - 80) %"}],"search_en":"Landfill gases Concentration of: carbon dioxide (CO2), methane (CH4) IR radiation absorption method CO2 CH4 PB-DPP-12 wersja 01 z dnia 21.01.2021 r.","technique_en":"IR radiation absorption method","test_object_en":"Landfill gases","parameters_zh":[{"name":"CO2","range":"(0,6 - 50) %"},{"name":"CH4","range":"(0,5 - 80) %"}],"search_zh":"填埋场气体 CO2 PB-DPP-12 wersja 01 z dnia 21.01.2021 r.","test_object_zh":"填埋场气体"},{"_id":"6a8369ecaf14b9c0e7b1de59","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Gazy składowiskowe","methodology":"Stężenie tlenu (O2)","parameters":[{"name":"Zakres","range":"(0,3 - 21) %"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Stężenie tlenu (O2)\nZakres (0,3 - 21) %\nMetoda elektrochemiczna","reference":"PB-DPP-12 wersja 01 z dnia 21.01.2021 r.","norm_bases":["PB-DPP-12 wersja 01 z dnia 21.01.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy składowiskowe Stężenie tlenu (O2)\nZakres (0,3 - 21) %\nMetoda elektrochemiczna PB-DPP-12 wersja 01 z dnia 21.01.2021 r. Gazy skladowiskowe Stezenie tlenu (O2)\nZakres (0,3 - 21) %\nMetoda elektrochemiczna PB-DPP-12 wersja 01 z dnia 21.01.2021 r.","categories":["other"],"row_index":567,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Oxygen (O2) concentration","parameters_en":[{"name":"Range","range":"(0,3 - 21) %"}],"search_en":"Landfill gases Oxygen (O2) concentration Electrochemical method Range PB-DPP-12 wersja 01 z dnia 21.01.2021 r.","technique_en":"Electrochemical method","test_object_en":"Landfill gases","parameters_zh":[{"name":"范围","range":"(0,3 - 21) %"}],"search_zh":"填埋场气体 电化学法 范围 PB-DPP-12 wersja 01 z dnia 21.01.2021 r.","technique_zh":"电化学法","test_object_zh":"填埋场气体"},{"_id":"6a8369ecaf14b9c0e7b1de5a","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Gazy składowiskowe","methodology":"Emisja dwutlenku węgla (CO2), metanu (CH4) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja dwutlenku węgla (CO2), metanu (CH4) (z obliczeń)","reference":"PB-DPP-12 wersja 01 z dnia 21.01.2021 r.","norm_bases":["PB-DPP-12 wersja 01 z dnia 21.01.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy składowiskowe Emisja dwutlenku węgla (CO2), metanu (CH4) (z obliczeń) PB-DPP-12 wersja 01 z dnia 21.01.2021 r. Gazy skladowiskowe Emisja dwutlenku wegla (CO2), metanu (CH4) (z obliczen) PB-DPP-12 wersja 01 z dnia 21.01.2021 r.","categories":["environment"],"row_index":568,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Landfill gases PB-DPP-12 wersja 01 z dnia 21.01.2021 r.","test_object_en":"Landfill gases","search_zh":"填埋场气体 PB-DPP-12 wersja 01 z dnia 21.01.2021 r.","test_object_zh":"填埋场气体"},{"_id":"6a8369ecaf14b9c0e7b1de5b","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Gazy składowiskowe","methodology":"Prędkość przepływu","parameters":[{"name":"Zakres","range":"(0,15 - 20) m/s"}],"technique":"Metoda termoanemometryczna","techniques":["Metoda termoanemometryczna"],"computed":[],"activity":"Prędkość przepływu\nZakres (0,15 - 20) m/s\nMetoda termoanemometryczna","reference":"PB-DPP-12 wersja 01 z dnia 21.01.2021 r.","norm_bases":["PB-DPP-12 wersja 01 z dnia 21.01.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy składowiskowe Prędkość przepływu\nZakres (0,15 - 20) m/s\nMetoda termoanemometryczna PB-DPP-12 wersja 01 z dnia 21.01.2021 r. Gazy skladowiskowe Predkosc przeplywu\nZakres (0,15 - 20) m/s\nMetoda termoanemometryczna PB-DPP-12 wersja 01 z dnia 21.01.2021 r.","categories":["other"],"row_index":569,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Flow velocity","parameters_en":[{"name":"Range","range":"(0,15 - 20) m/s"}],"search_en":"Landfill gases Flow velocity Thermoanemometric method Range PB-DPP-12 wersja 01 z dnia 21.01.2021 r.","technique_en":"Thermoanemometric method","test_object_en":"Landfill gases","parameters_zh":[{"name":"范围","range":"(0,15 - 20) m/s"}],"search_zh":"填埋场气体 流速 热线风速仪法 范围 PB-DPP-12 wersja 01 z dnia 21.01.2021 r.","test_object_zh":"填埋场气体","methodology_zh":"流速","technique_zh":"热线风速仪法"},{"_id":"6a8369ecaf14b9c0e7b1de5c","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Powietrze","methodology":"Pobieranie próbek do badań mikrobiologicznych","parameters":[],"technique":"Metoda impakcji (zderzeniowa)","techniques":["Metoda impakcji (zderzeniowa)"],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych\nMetoda impakcji (zderzeniowa)","reference":"ISO 8573-7:2003 | PN-EN 13098:2020-01","norm_bases":["ISO 8573-7:2003","PN-EN 13098:2020-01"],"lab_section":"Pracownia Środowiskowa, Dział Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Powietrze Pobieranie próbek do badań mikrobiologicznych\nMetoda impakcji (zderzeniowa) ISO 8573-7:2003 | PN-EN 13098:2020-01 Powietrze Pobieranie probek do badan mikrobiologicznych\nMetoda impakcji (zderzeniowa) ISO 8573-7:2003 | PN-EN 13098:2020-01","categories":["environment","microbiology"],"row_index":570,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for microbiological testing","search_en":"Air Sampling for microbiological testing Impaction method (impingement) ISO 8573-7:2003 | PN-EN 13098:2020-01","technique_en":"Impaction method (impingement)","test_object_en":"Air","methodology_zh":"微生物检测用样品采集","search_zh":"空气 微生物检测用样品采集 ISO 8573-7:2003 | PN-EN 13098:2020-01","test_object_zh":"空气"},{"_id":"6a8369ecaf14b9c0e7b1de5d","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Powietrze","methodology":"Pobieranie próbek do badań mikrobiologicznych","parameters":[],"technique":"Metoda filtracji","techniques":["Metoda filtracji"],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych\nMetoda filtracji","reference":"PN-EN 13098:2020-01","norm_bases":["PN-EN 13098:2020-01"],"lab_section":"Pracownia Środowiskowa, Dział Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Powietrze Pobieranie próbek do badań mikrobiologicznych\nMetoda filtracji PN-EN 13098:2020-01 Powietrze Pobieranie probek do badan mikrobiologicznych\nMetoda filtracji PN-EN 13098:2020-01","categories":["environment","microbiology"],"row_index":571,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for microbiological testing","search_en":"Air Sampling for microbiological testing Filtration method PN-EN 13098:2020-01","technique_en":"Filtration method","test_object_en":"Air","methodology_zh":"微生物检测用样品采集","search_zh":"空气 微生物检测用样品采集 PN-EN 13098:2020-01","test_object_zh":"空气"},{"_id":"6a8369ecaf14b9c0e7b1de5e","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Powietrze","methodology":"Pobieranie próbek do badań mikrobiologicznych","parameters":[],"technique":"Metoda sedymentacyjna","techniques":["Metoda sedymentacyjna"],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych\nMetoda sedymentacyjna","reference":"PB-DPP-21 wydanie 02 z dnia 01.03.2023","norm_bases":["PB-DPP-21 wydanie 02 z dnia 01.03.2023"],"lab_section":"Pracownia Środowiskowa, Dział Pobierania Próbek","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Powietrze Pobieranie próbek do badań mikrobiologicznych\nMetoda sedymentacyjna PB-DPP-21 wydanie 02 z dnia 01.03.2023 Powietrze Pobieranie probek do badan mikrobiologicznych\nMetoda sedymentacyjna PB-DPP-21 wydanie 02 z dnia 01.03.2023","categories":["environment","microbiology"],"row_index":572,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for microbiological testing","search_en":"Air Sampling for microbiological testing Sedimentation method PB-DPP-21 wydanie 02 z dnia 01.03.2023","technique_en":"Sedimentation method","test_object_en":"Air","methodology_zh":"微生物检测用样品采集","search_zh":"空气 微生物检测用样品采集 PB-DPP-21 wydanie 02 z dnia 01.03.2023","test_object_zh":"空气"},{"_id":"6a8369ecaf14b9c0e7b1de5f","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Odpady kod: 20 03 01, 20 03 99, 19 12 12","methodology":"Pobieranie próbek odpadów w celu oznaczania składu morfologicznego i sitowego","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek odpadów w celu oznaczania składu morfologicznego i sitowego","reference":"PB-DPP-46 wersja 01 z dnia 21.01.2021 r.","norm_bases":["PB-DPP-46 wersja 01 z dnia 21.01.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Pobierania Próbek","lab_address":null,"regulatory_area":"Badania i pobieranie wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Środowiska z dnia 15 grudnia 2017 roku w sprawie poziomów ograniczenia składowania masy odpadów komunalnych ulegających biodegradacji (Dz. U. z 2017, poz. 2412) - Rozporządzeniem Ministra Środowiska z dnia 14 grudnia 2016 roku w sprawie poziomów recyklingu, przygotowania do ponownego użycia i odzysku innymi metodami niektórych frakcji odpadów komunalnych (Dz. U. z 2016 r., poz 2167). | Pobieranie wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 roku w sprawie w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. z 2015, poz. 1277) - Rozporządzeniem Ministra Środowiska z dnia 28 grudnia 2011 roku w sprawie w sprawie podziemnych składowisk odpadów (Dz. U. z 2011 nr 298, poz. 1771) - Rozporządzenie Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (DZ. U. z 2017, poz. 2490) - Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2023. poz. 23) - Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 roku w sprawie procesu R10 (Dz. U. z 2015, poz. 132) | Pobieranie wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 roku w sprawie w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. z 2015, poz. 1277) - Rozporządzeniem Ministra Środowiska z dnia 28 grudnia 2011 roku w sprawie w sprawie podziemnych składowisk odpadów (Dz. U. z 2011 nr 298, poz. 1771) - Rozporządzenie Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (DZ. U. z 2017, poz. 2490) | Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 20 03 01, 20 03 99, 19 12 12 Pobieranie próbek odpadów w celu oznaczania składu morfologicznego i sitowego PB-DPP-46 wersja 01 z dnia 21.01.2021 r. Odpady kod: 20 03 01, 20 03 99, 19 12 12 Pobieranie probek odpadow w celu oznaczania skladu morfologicznego i sitowego PB-DPP-46 wersja 01 z dnia 21.01.2021 r.","categories":["environment"],"row_index":573,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Waste sampling for determination of the morphological and sieve composition","search_en":"Waste code: 20 03 01, 20 03 99, 19 12 12 Waste sampling for determination of the morphological and sieve composition PB-DPP-46 wersja 01 z dnia 21.01.2021 r.","test_object_en":"Waste code: 20 03 01, 20 03 99, 19 12 12"},{"_id":"6a8369ecaf14b9c0e7b1de60","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Odpady kod: 20 03 01, 20 03 99, 19 12 12","methodology":"Oznaczanie składu morfologicznego i sitowego","parameters":[{"name":"Zakres","range":"(0,1 - 99,9) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Oznaczanie składu morfologicznego i sitowego\nZakres (0,1 - 99,9) %\nMetoda wagowa","reference":"PB-DPP-47 wersja 01 z dnia 21.01.2021 r.","norm_bases":["PB-DPP-47 wersja 01 z dnia 21.01.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Pobierania Próbek","lab_address":null,"regulatory_area":"Badania i pobieranie wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Środowiska z dnia 15 grudnia 2017 roku w sprawie poziomów ograniczenia składowania masy odpadów komunalnych ulegających biodegradacji (Dz. U. z 2017, poz. 2412) - Rozporządzeniem Ministra Środowiska z dnia 14 grudnia 2016 roku w sprawie poziomów recyklingu, przygotowania do ponownego użycia i odzysku innymi metodami niektórych frakcji odpadów komunalnych (Dz. U. z 2016 r., poz 2167). | Pobieranie wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 roku w sprawie w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. z 2015, poz. 1277) - Rozporządzeniem Ministra Środowiska z dnia 28 grudnia 2011 roku w sprawie w sprawie podziemnych składowisk odpadów (Dz. U. z 2011 nr 298, poz. 1771) - Rozporządzenie Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (DZ. U. z 2017, poz. 2490) - Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2023. poz. 23) - Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 roku w sprawie procesu R10 (Dz. U. z 2015, poz. 132) | Pobieranie wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 roku w sprawie w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. z 2015, poz. 1277) - Rozporządzeniem Ministra Środowiska z dnia 28 grudnia 2011 roku w sprawie w sprawie podziemnych składowisk odpadów (Dz. U. z 2011 nr 298, poz. 1771) - Rozporządzenie Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (DZ. U. z 2017, poz. 2490) | Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 20 03 01, 20 03 99, 19 12 12 Oznaczanie składu morfologicznego i sitowego\nZakres (0,1 - 99,9) %\nMetoda wagowa PB-DPP-47 wersja 01 z dnia 21.01.2021 r. Odpady kod: 20 03 01, 20 03 99, 19 12 12 Oznaczanie skladu morfologicznego i sitowego\nZakres (0,1 - 99,9) %\nMetoda wagowa PB-DPP-47 wersja 01 z dnia 21.01.2021 r.","categories":["environment"],"row_index":574,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Determination of morphological and sieve composition","parameters_en":[{"name":"Range","range":"(0,1 - 99,9) %"}],"search_en":"Waste code: 20 03 01, 20 03 99, 19 12 12 Determination of morphological and sieve composition Gravimetric method Range PB-DPP-47 wersja 01 z dnia 21.01.2021 r.","technique_en":"Gravimetric method","test_object_en":"Waste code: 20 03 01, 20 03 99, 19 12 12","parameters_zh":[{"name":"范围","range":"(0,1 - 99,9) %"}],"search_zh":"重量法 范围 PB-DPP-47 wersja 01 z dnia 21.01.2021 r.","technique_zh":"重量法"},{"_id":"6a8369ecaf14b9c0e7b1de61","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Odpady kod: 02 02 04, 02 03 01, 02 03 05, 02 03 80, 02 05 02, 02 06 03, 02 07 05, 19 08 05, 19 09 01, 19 09 02, Osady ściekowe","methodology":"Pobieranie próbek do badań chemicznych, fizycznych, badań mikrobiologicznych oraz parazytologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych, fizycznych, badań mikrobiologicznych oraz parazytologicznych","reference":"PN-EN ISO 5667-13:2011","norm_bases":["PN-EN ISO 5667-13:2011"],"lab_section":"Pracownia Środowiskowa, Dział Pobierania Próbek","lab_address":null,"regulatory_area":"Badania i pobieranie wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Środowiska z dnia 15 grudnia 2017 roku w sprawie poziomów ograniczenia składowania masy odpadów komunalnych ulegających biodegradacji (Dz. U. z 2017, poz. 2412) - Rozporządzeniem Ministra Środowiska z dnia 14 grudnia 2016 roku w sprawie poziomów recyklingu, przygotowania do ponownego użycia i odzysku innymi metodami niektórych frakcji odpadów komunalnych (Dz. U. z 2016 r., poz 2167). | Pobieranie wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 roku w sprawie w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. z 2015, poz. 1277) - Rozporządzeniem Ministra Środowiska z dnia 28 grudnia 2011 roku w sprawie w sprawie podziemnych składowisk odpadów (Dz. U. z 2011 nr 298, poz. 1771) - Rozporządzenie Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (DZ. U. z 2017, poz. 2490) - Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2023. poz. 23) - Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 roku w sprawie procesu R10 (Dz. U. z 2015, poz. 132) | Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 02 02 04, 02 03 01, 02 03 05, 02 03 80, 02 05 02, 02 06 03, 02 07 05, 19 08 05, 19 09 01, 19 09 02, Osady ściekowe Pobieranie próbek do badań chemicznych, fizycznych, badań mikrobiologicznych oraz parazytologicznych PN-EN ISO 5667-13:2011 Odpady kod: 02 02 04, 02 03 01, 02 03 05, 02 03 80, 02 05 02, 02 06 03, 02 07 05, 19 08 05, 19 09 01, 19 09 02, Osady sciekowe Pobieranie probek do badan chemicznych, fizycznych, badan mikrobiologicznych oraz parazytologicznych PN-EN ISO 5667-13:2011","categories":["water","environment","microbiology"],"row_index":575,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical, physical, microbiological and parasitological testing","search_en":"Waste code: 02 02 04, 02 03 01, 02 03 05, 02 03 80, 02 05 02, 02 06 03, 02 07 05, 19 08 05, 19 09 01, 19 09 02, Sewage sludge Sampling for chemical, physical, microbiological and parasitological testing PN-EN ISO 5667-13:2011","test_object_en":"Waste code: 02 02 04, 02 03 01, 02 03 05, 02 03 80, 02 05 02, 02 06 03, 02 07 05, 19 08 05, 19 09 01, 19 09 02, Sewage sludge"},{"_id":"6a8369ecaf14b9c0e7b1de62","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Odpady kod: 02 01 03, 19 05 03, 19 05 99, 19 06 04","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-Z-15011-1:1998","norm_bases":["PN-Z-15011-1:1998"],"lab_section":"Pracownia Środowiskowa, Dział Pobierania Próbek","lab_address":null,"regulatory_area":"Badania i pobieranie wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Środowiska z dnia 15 grudnia 2017 roku w sprawie poziomów ograniczenia składowania masy odpadów komunalnych ulegających biodegradacji (Dz. U. z 2017, poz. 2412) - Rozporządzeniem Ministra Środowiska z dnia 14 grudnia 2016 roku w sprawie poziomów recyklingu, przygotowania do ponownego użycia i odzysku innymi metodami niektórych frakcji odpadów komunalnych (Dz. U. z 2016 r., poz 2167). | Pobieranie wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 roku w sprawie w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. z 2015, poz. 1277) - Rozporządzeniem Ministra Środowiska z dnia 28 grudnia 2011 roku w sprawie w sprawie podziemnych składowisk odpadów (Dz. U. z 2011 nr 298, poz. 1771) - Rozporządzenie Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (DZ. U. z 2017, poz. 2490) - Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2023. poz. 23) - Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 roku w sprawie procesu R10 (Dz. U. z 2015, poz. 132) | Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 02 01 03, 19 05 03, 19 05 99, 19 06 04 Pobieranie próbek do badań chemicznych i fizycznych PN-Z-15011-1:1998 Odpady kod: 02 01 03, 19 05 03, 19 05 99, 19 06 04 Pobieranie probek do badan chemicznych i fizycznych PN-Z-15011-1:1998","categories":["environment"],"row_index":576,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Waste code: 02 01 03, 19 05 03, 19 05 99, 19 06 04 Sampling for chemical and physical testing PN-Z-15011-1:1998","test_object_en":"Waste code: 02 01 03, 19 05 03, 19 05 99, 19 06 04","methodology_zh":"化学与物理检测用样品采集","search_zh":"化学与物理检测用样品采集 PN-Z-15011-1:1998"},{"_id":"6a8369ecaf14b9c0e7b1de63","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Odpady kod: 03 01 05, 10 01 01, 17 01 07, 17 01 81, 17 03 02, 17 03 80, 17 06 04, 17 09 04, 19 01 12, 19 05 99, 19 08 01, 19 08 02, 19 09 01, 19 09 02, 19 12 09, 19 12 10, 19 12 11*, 19 12 12, 19 05 01, 20 01 99, 20 02 03, 20 03 01, 20 03 03, 20 03 06, 20 03 07, 20 03 99","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PB-DPP-11 wersja 02 z dnia 01.03.2024 r.","norm_bases":["PB-DPP-11 wersja 02 z dnia 01.03.2024 r."],"lab_section":"Pracownia Środowiskowa, Dział Pobierania Próbek","lab_address":null,"regulatory_area":"Badania i pobieranie wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Środowiska z dnia 15 grudnia 2017 roku w sprawie poziomów ograniczenia składowania masy odpadów komunalnych ulegających biodegradacji (Dz. U. z 2017, poz. 2412) - Rozporządzeniem Ministra Środowiska z dnia 14 grudnia 2016 roku w sprawie poziomów recyklingu, przygotowania do ponownego użycia i odzysku innymi metodami niektórych frakcji odpadów komunalnych (Dz. U. z 2016 r., poz 2167). | Pobieranie wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 roku w sprawie w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. z 2015, poz. 1277) - Rozporządzeniem Ministra Środowiska z dnia 28 grudnia 2011 roku w sprawie w sprawie podziemnych składowisk odpadów (Dz. U. z 2011 nr 298, poz. 1771) - Rozporządzenie Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (DZ. U. z 2017, poz. 2490) - Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2023. poz. 23) - Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 roku w sprawie procesu R10 (Dz. U. z 2015, poz. 132) | Pobieranie wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 roku w sprawie w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. z 2015, poz. 1277) - Rozporządzeniem Ministra Środowiska z dnia 28 grudnia 2011 roku w sprawie w sprawie podziemnych składowisk odpadów (Dz. U. z 2011 nr 298, poz. 1771) - Rozporządzenie Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (DZ. U. z 2017, poz. 2490) | Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 03 01 05, 10 01 01, 17 01 07, 17 01 81, 17 03 02, 17 03 80, 17 06 04, 17 09 04, 19 01 12, 19 05 99, 19 08 01, 19 08 02, 19 09 01, 19 09 02, 19 12 09, 19 12 10, 19 12 11*, 19 12 12, 19 05 01, 20 01 99, 20 02 03, 20 03 01, 20 03 03, 20 03 06, 20 03 07, 20 03 99 Pobieranie próbek do badań chemicznych i fizycznych PB-DPP-11 wersja 02 z dnia 01.03.2024 r. Odpady kod: 03 01 05, 10 01 01, 17 01 07, 17 01 81, 17 03 02, 17 03 80, 17 06 04, 17 09 04, 19 01 12, 19 05 99, 19 08 01, 19 08 02, 19 09 01, 19 09 02, 19 12 09, 19 12 10, 19 12 11*, 19 12 12, 19 05 01, 20 01 99, 20 02 03, 20 03 01, 20 03 03, 20 03 06, 20 03 07, 20 03 99 Pobieranie probek do badan chemicznych i fizycznych PB-DPP-11 wersja 02 z dnia 01.03.2024 r.","categories":["environment"],"row_index":577,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Waste code: 03 01 05, 10 01 01, 17 01 07, 17 01 81, 17 03 02, 17 03 80, 17 06 04, 17 09 04, 19 01 12, 19 05 99, 19 08 01, 19 08 02, 19 09 01, 19 09 02, 19 12 09, 19 12 10, 19 12 11*, 19 12 12, 19 05 01, 20 01 99, 20 02 03, 20 03 01, 20 03 03, 20 03 06, 20 03 07, 20 03 99 Sampling for chemical and physical testing PB-DPP-11 wersja 02 z dnia 01.03.2024 r.","test_object_en":"Waste code: 03 01 05, 10 01 01, 17 01 07, 17 01 81, 17 03 02, 17 03 80, 17 06 04, 17 09 04, 19 01 12, 19 05 99, 19 08 01, 19 08 02, 19 09 01, 19 09 02, 19 12 09, 19 12 10, 19 12 11*, 19 12 12, 19 05 01, 20 01 99, 20 02 03, 20 03 01, 20 03 03, 20 03 06, 20 03 07, 20 03 99","methodology_zh":"化学与物理检测用样品采集","search_zh":"化学与物理检测用样品采集 PB-DPP-11 wersja 02 z dnia 01.03.2024 r."},{"_id":"6a8369ecaf14b9c0e7b1de64","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Odpady kod: 02 04 03, 03 01 82, 03 03 11, 04 01 06, 04 01 07, 06 05 02*, 06 05 03, 07 01 12, 07 02 11*, 07 02 12, 07 03 12, 07 04 12, 07 05 12, 07 06 12, 07 07 12, 10 01 20*, 10 01 21, 19 06 05, 19 08 12, 19 08 14, 19 09 03, 20 03 04","methodology":"Pobieranie próbek do badań chemicznych, fizycznych, badań mikrobiologicznych oraz parazytologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych, fizycznych, badań mikrobiologicznych oraz parazytologicznych","reference":"PN-EN ISO 5667-13:2011","norm_bases":["PN-EN ISO 5667-13:2011"],"lab_section":"Pracownia Środowiskowa, Dział Pobierania Próbek","lab_address":null,"regulatory_area":"Badania i pobieranie wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Środowiska z dnia 15 grudnia 2017 roku w sprawie poziomów ograniczenia składowania masy odpadów komunalnych ulegających biodegradacji (Dz. U. z 2017, poz. 2412) - Rozporządzeniem Ministra Środowiska z dnia 14 grudnia 2016 roku w sprawie poziomów recyklingu, przygotowania do ponownego użycia i odzysku innymi metodami niektórych frakcji odpadów komunalnych (Dz. U. z 2016 r., poz 2167). | Pobieranie wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 roku w sprawie w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. z 2015, poz. 1277) - Rozporządzeniem Ministra Środowiska z dnia 28 grudnia 2011 roku w sprawie w sprawie podziemnych składowisk odpadów (Dz. U. z 2011 nr 298, poz. 1771) - Rozporządzenie Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (DZ. U. z 2017, poz. 2490) - Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2023. poz. 23) - Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 roku w sprawie procesu R10 (Dz. U. z 2015, poz. 132) | Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 02 04 03, 03 01 82, 03 03 11, 04 01 06, 04 01 07, 06 05 02*, 06 05 03, 07 01 12, 07 02 11*, 07 02 12, 07 03 12, 07 04 12, 07 05 12, 07 06 12, 07 07 12, 10 01 20*, 10 01 21, 19 06 05, 19 08 12, 19 08 14, 19 09 03, 20 03 04 Pobieranie próbek do badań chemicznych, fizycznych, badań mikrobiologicznych oraz parazytologicznych PN-EN ISO 5667-13:2011 Odpady kod: 02 04 03, 03 01 82, 03 03 11, 04 01 06, 04 01 07, 06 05 02*, 06 05 03, 07 01 12, 07 02 11*, 07 02 12, 07 03 12, 07 04 12, 07 05 12, 07 06 12, 07 07 12, 10 01 20*, 10 01 21, 19 06 05, 19 08 12, 19 08 14, 19 09 03, 20 03 04 Pobieranie probek do badan chemicznych, fizycznych, badan mikrobiologicznych oraz parazytologicznych PN-EN ISO 5667-13:2011","categories":["environment","microbiology"],"row_index":578,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical, physical, microbiological and parasitological testing","search_en":"Waste code: 02 04 03, 03 01 82, 03 03 11, 04 01 06, 04 01 07, 06 05 02*, 06 05 03, 07 01 12, 07 02 11*, 07 02 12, 07 03 12, 07 04 12, 07 05 12, 07 06 12, 07 07 12, 10 01 20*, 10 01 21, 19 06 05, 19 08 12, 19 08 14, 19 09 03, 20 03 04 Sampling for chemical, physical, microbiological and parasitological testing PN-EN ISO 5667-13:2011","test_object_en":"Waste code: 02 04 03, 03 01 82, 03 03 11, 04 01 06, 04 01 07, 06 05 02*, 06 05 03, 07 01 12, 07 02 11*, 07 02 12, 07 03 12, 07 04 12, 07 05 12, 07 06 12, 07 07 12, 10 01 20*, 10 01 21, 19 06 05, 19 08 12, 19 08 14, 19 09 03, 20 03 04"},{"_id":"6a8369ecaf14b9c0e7b1de65","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Odpady kod: 19 05 02, 20 01 08, 20 02 01, 20 03 02","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-Z-15011-1:1998","norm_bases":["PN-Z-15011-1:1998"],"lab_section":"Pracownia Środowiskowa, Dział Pobierania Próbek","lab_address":null,"regulatory_area":"Badania i pobieranie wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Środowiska z dnia 15 grudnia 2017 roku w sprawie poziomów ograniczenia składowania masy odpadów komunalnych ulegających biodegradacji (Dz. U. z 2017, poz. 2412) - Rozporządzeniem Ministra Środowiska z dnia 14 grudnia 2016 roku w sprawie poziomów recyklingu, przygotowania do ponownego użycia i odzysku innymi metodami niektórych frakcji odpadów komunalnych (Dz. U. z 2016 r., poz 2167). | Pobieranie wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 roku w sprawie w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. z 2015, poz. 1277) - Rozporządzeniem Ministra Środowiska z dnia 28 grudnia 2011 roku w sprawie w sprawie podziemnych składowisk odpadów (Dz. U. z 2011 nr 298, poz. 1771) - Rozporządzenie Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (DZ. U. z 2017, poz. 2490) - Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2023. poz. 23) - Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 roku w sprawie procesu R10 (Dz. U. z 2015, poz. 132) | Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 19 05 02, 20 01 08, 20 02 01, 20 03 02 Pobieranie próbek do badań chemicznych i fizycznych PN-Z-15011-1:1998 Odpady kod: 19 05 02, 20 01 08, 20 02 01, 20 03 02 Pobieranie probek do badan chemicznych i fizycznych PN-Z-15011-1:1998","categories":["environment"],"row_index":579,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Waste code: 19 05 02, 20 01 08, 20 02 01, 20 03 02 Sampling for chemical and physical testing PN-Z-15011-1:1998","test_object_en":"Waste code: 19 05 02, 20 01 08, 20 02 01, 20 03 02","methodology_zh":"化学与物理检测用样品采集","search_zh":"化学与物理检测用样品采集 PN-Z-15011-1:1998"},{"_id":"6a8369ecaf14b9c0e7b1de66","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Odpady kod: 02 01 04, 03 01 05, 07 02 13, 10 01 14*, 10 01 15, 10 01 16*, 10 01 17, 10 01 18*, 10 01 19, 15 01 01,15 01 02, 15 01 03, 15 01 05, 15 01 06, 15 01 07, 15 01 09, 15 02 03, 17 01 01, 17 01 02, 17 01 03, 17 01 06*, 17 01 80, 17 01 82, 17 02 01, 17 02 02, 17 02 03, 17 05 03*, 17 05 04, 17 05 05*, 17 05 06, 17 05 07*, 17 05 08, 19 01 07*, 19 01 11*, 19 12 01, 19 12 04, 19 12 05, 19 12 06*, 19 12 07, 19 12 08, 20 01 01, 20 01 02, 20 01 10, 20 01 11, 20 01 38, 20 01 39, 20 02 02","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PB-DPP-11 wersja 02 z dnia 01.03.2024 r.","norm_bases":["PB-DPP-11 wersja 02 z dnia 01.03.2024 r."],"lab_section":"Pracownia Środowiskowa, Dział Pobierania Próbek","lab_address":null,"regulatory_area":"Badania i pobieranie wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Środowiska z dnia 15 grudnia 2017 roku w sprawie poziomów ograniczenia składowania masy odpadów komunalnych ulegających biodegradacji (Dz. U. z 2017, poz. 2412) - Rozporządzeniem Ministra Środowiska z dnia 14 grudnia 2016 roku w sprawie poziomów recyklingu, przygotowania do ponownego użycia i odzysku innymi metodami niektórych frakcji odpadów komunalnych (Dz. U. z 2016 r., poz 2167). | Pobieranie wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 roku w sprawie w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. z 2015, poz. 1277) - Rozporządzeniem Ministra Środowiska z dnia 28 grudnia 2011 roku w sprawie w sprawie podziemnych składowisk odpadów (Dz. U. z 2011 nr 298, poz. 1771) - Rozporządzenie Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (DZ. U. z 2017, poz. 2490) - Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2023. poz. 23) - Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 roku w sprawie procesu R10 (Dz. U. z 2015, poz. 132) | Pobieranie wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 roku w sprawie w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. z 2015, poz. 1277) - Rozporządzeniem Ministra Środowiska z dnia 28 grudnia 2011 roku w sprawie w sprawie podziemnych składowisk odpadów (Dz. U. z 2011 nr 298, poz. 1771) - Rozporządzenie Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (DZ. U. z 2017, poz. 2490) | Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 02 01 04, 03 01 05, 07 02 13, 10 01 14*, 10 01 15, 10 01 16*, 10 01 17, 10 01 18*, 10 01 19, 15 01 01,15 01 02, 15 01 03, 15 01 05, 15 01 06, 15 01 07, 15 01 09, 15 02 03, 17 01 01, 17 01 02, 17 01 03, 17 01 06*, 17 01 80, 17 01 82, 17 02 01, 17 02 02, 17 02 03, 17 05 03*, 17 05 04, 17 05 05*, 17 05 06, 17 05 07*, 17 05 08, 19 01 07*, 19 01 11*, 19 12 01, 19 12 04, 19 12 05, 19 12 06*, 19 12 07, 19 12 08, 20 01 01, 20 01 02, 20 01 10, 20 01 11, 20 01 38, 20 01 39, 20 02 02 Pobieranie próbek do badań chemicznych i fizycznych PB-DPP-11 wersja 02 z dnia 01.03.2024 r. Odpady kod: 02 01 04, 03 01 05, 07 02 13, 10 01 14*, 10 01 15, 10 01 16*, 10 01 17, 10 01 18*, 10 01 19, 15 01 01,15 01 02, 15 01 03, 15 01 05, 15 01 06, 15 01 07, 15 01 09, 15 02 03, 17 01 01, 17 01 02, 17 01 03, 17 01 06*, 17 01 80, 17 01 82, 17 02 01, 17 02 02, 17 02 03, 17 05 03*, 17 05 04, 17 05 05*, 17 05 06, 17 05 07*, 17 05 08, 19 01 07*, 19 01 11*, 19 12 01, 19 12 04, 19 12 05, 19 12 06*, 19 12 07, 19 12 08, 20 01 01, 20 01 02, 20 01 10, 20 01 11, 20 01 38, 20 01 39, 20 02 02 Pobieranie probek do badan chemicznych i fizycznych PB-DPP-11 wersja 02 z dnia 01.03.2024 r.","categories":["environment"],"row_index":580,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Waste code: 02 01 04, 03 01 05, 07 02 13, 10 01 14*, 10 01 15, 10 01 16*, 10 01 17, 10 01 18*, 10 01 19, 15 01 01,15 01 02, 15 01 03, 15 01 05, 15 01 06, 15 01 07, 15 01 09, 15 02 03, 17 01 01, 17 01 02, 17 01 03, 17 01 06*, 17 01 80, 17 01 82, 17 02 01, 17 02 02, 17 02 03, 17 05 03*, 17 05 04, 17 05 05*, 17 05 06, 17 05 07*, 17 05 08, 19 01 07*, 19 01 11*, 19 12 01, 19 12 04, 19 12 05, 19 12 06*, 19 12 07, 19 12 08, 20 01 01, 20 01 02, 20 01 10, 20 01 11, 20 01 38, 20 01 39, 20 02 02 Sampling for chemical and physical testing PB-DPP-11 wersja 02 z dnia 01.03.2024 r.","test_object_en":"Waste code: 02 01 04, 03 01 05, 07 02 13, 10 01 14*, 10 01 15, 10 01 16*, 10 01 17, 10 01 18*, 10 01 19, 15 01 01,15 01 02, 15 01 03, 15 01 05, 15 01 06, 15 01 07, 15 01 09, 15 02 03, 17 01 01, 17 01 02, 17 01 03, 17 01 06*, 17 01 80, 17 01 82, 17 02 01, 17 02 02, 17 02 03, 17 05 03*, 17 05 04, 17 05 05*, 17 05 06, 17 05 07*, 17 05 08, 19 01 07*, 19 01 11*, 19 12 01, 19 12 04, 19 12 05, 19 12 06*, 19 12 07, 19 12 08, 20 01 01, 20 01 02, 20 01 10, 20 01 11, 20 01 38, 20 01 39, 20 02 02","methodology_zh":"化学与物理检测用样品采集","search_zh":"化学与物理检测用样品采集 PB-DPP-11 wersja 02 z dnia 01.03.2024 r."},{"_id":"6a8369ecaf14b9c0e7b1de67","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Odpady kod: 17 03 02","methodology":"Pobieranie „ex situ” próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie „ex situ” próbek do badań chemicznych i fizycznych","reference":"PB-DPP-11 wersja 02 z dnia 01.03.2024 r.","norm_bases":["PB-DPP-11 wersja 02 z dnia 01.03.2024 r."],"lab_section":"Pracownia Środowiskowa, Dział Pobierania Próbek","lab_address":null,"regulatory_area":"Pobieranie wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 roku w sprawie w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. z 2015, poz. 1277) - Rozporządzeniem Ministra Środowiska z dnia 28 grudnia 2011 roku w sprawie w sprawie podziemnych składowisk odpadów (Dz. U. z 2011 nr 298, poz. 1771) - Rozporządzenie Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (DZ. U. z 2017, poz. 2490) - Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2023, poz. 23) - Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 roku w sprawie procesu R10 (Dz. U. z 2015, poz. | Pobieranie wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Klimatu i Środowiska z dnia 23 grudnia 2021 roku w sprawie szczegółowych warunków utraty statusu odpadów dla odpadów destruktu asfaltowego (Dz. U. z 2021, poz. 2468), Ust.2 | Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady kod: 17 03 02 Pobieranie „ex situ” próbek do badań chemicznych i fizycznych PB-DPP-11 wersja 02 z dnia 01.03.2024 r. Odpady kod: 17 03 02 Pobieranie „ex situ” probek do badan chemicznych i fizycznych PB-DPP-11 wersja 02 z dnia 01.03.2024 r.","categories":["environment"],"row_index":581,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"„Ex situ” sampling for chemical and physical testing","search_en":"Waste code: 17 03 02 „Ex situ” sampling for chemical and physical testing PB-DPP-11 wersja 02 z dnia 01.03.2024 r.","test_object_en":"Waste code: 17 03 02"},{"_id":"6a8369ecaf14b9c0e7b1de68","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Pobieranie próbek w celu oceny narażenia zawodowego na:","parameters":[{"name":"czynniki pyłowe – frakcja wdychalna – frakcja respirabilna"}],"technique":"Metoda dozymetrii indywidualnej","techniques":["Metoda dozymetrii indywidualnej"],"computed":[],"activity":"Pobieranie próbek w celu oceny narażenia zawodowego na:\nczynniki pyłowe – frakcja wdychalna – frakcja respirabilna\nMetoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002 + Az1:2004","norm_bases":["PN-Z-04008-7:2002 + Az1:2004"],"lab_section":"Pracownia Środowiskowa, Dział Pomiarów Jakości Środowiska - Stanowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Pobieranie próbek w celu oceny narażenia zawodowego na:\nczynniki pyłowe – frakcja wdychalna – frakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002 + Az1:2004 Srodowisko pracy – powietrze Pobieranie probek w celu oceny narazenia zawodowego na:\nczynniki pylowe – frakcja wdychalna – frakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002 + Az1:2004","categories":["environment"],"row_index":582,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for the assessment of occupational exposure to:","parameters_en":[{"name":"dust agents – inhalable fraction – respirable fraction"}],"search_en":"Workplace environment – air Sampling for the assessment of occupational exposure to: Personal dosimetry method dust agents – inhalable fraction – respirable fraction PN-Z-04008-7:2002 + Az1:2004","technique_en":"Personal dosimetry method","test_object_en":"Workplace environment – air","search_zh":"工作场所环境 — 空气 职业接触评估采样，针对： 个体剂量测定法 粉尘因素 — 可吸入组分 — 呼吸性组分 PN-Z-04008-7:2002 + Az1:2004","technique_zh":"个体剂量测定法","test_object_zh":"工作场所环境 — 空气","parameters_zh":[{"name":"粉尘因素 — 可吸入组分 — 呼吸性组分"}],"methodology_zh":"职业接触评估采样，针对："},{"_id":"6a8369ecaf14b9c0e7b1de69","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Pobieranie próbek w celu oceny narażenia zawodowego na:","parameters":[{"name":"azbest – włókna respirabilne"},{"name":"ogniotrwałe włókna ceramiczne"},{"name":"ogniotrwałe włókna ceramiczne w mieszaninie z innymi sztucznymi włóknami mineralnymi"},{"name":"sztuczne włókna mineralne, z wyjątkiem ogniotrwałych włókien ceramicznych – włókna respirabilne"},{"name":"substancje organiczne, w tym – frakcja wdychalna"},{"name":"substancje nieorganiczne, w tym – frakcja wdychalna – frakcja respirabilna – frakcja torakalna"},{"name":"metale i ich związki, w tym – frakcja wdychalna – frakcja respirabilna"}],"technique":"Metoda dozymetrii indywidualnej","techniques":["Metoda dozymetrii indywidualnej"],"computed":[],"activity":"Pobieranie próbek w celu oceny narażenia zawodowego na:\nZakres:\nazbest – włókna respirabilne\nogniotrwałe włókna ceramiczne\nogniotrwałe włókna ceramiczne w mieszaninie z innymi sztucznymi włóknami mineralnymi\nsztuczne włókna mineralne, z wyjątkiem ogniotrwałych włókien ceramicznych – włókna respirabilne\nsubstancje organiczne, w tym – frakcja wdychalna\nsubstancje nieorganiczne, w tym – frakcja wdychalna – frakcja respirabilna – frakcja torakalna\nmetale i ich związki, w tym – frakcja wdychalna – frakcja respirabilna\nMetoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002 + Az1:2004","norm_bases":["PN-Z-04008-7:2002 + Az1:2004"],"lab_section":"Pracownia Środowiskowa, Dział Pomiarów Jakości Środowiska - Stanowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Pobieranie próbek w celu oceny narażenia zawodowego na:\nZakres:\nazbest – włókna respirabilne\nogniotrwałe włókna ceramiczne\nogniotrwałe włókna ceramiczne w mieszaninie z innymi sztucznymi włóknami mineralnymi\nsztuczne włókna mineralne, z wyjątkiem ogniotrwałych włókien ceramicznych – włókna respirabilne\nsubstancje organiczne, w tym – frakcja wdychalna\nsubstancje nieorganiczne, w tym – frakcja wdychalna – frakcja respirabilna – frakcja torakalna\nmetale i ich związki, w tym – frakcja wdychalna – frakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002 + Az1:2004 Srodowisko pracy – powietrze Pobieranie probek w celu oceny narazenia zawodowego na:\nZakres:\nazbest – wlokna respirabilne\nogniotrwale wlokna ceramiczne\nogniotrwale wlokna ceramiczne w mieszaninie z innymi sztucznymi wloknami mineralnymi\nsztuczne wlokna mineralne, z wyjatkiem ogniotrwalych wlokien ceramicznych – wlokna respirabilne\nsubstancje organiczne, w tym – frakcja wdychalna\nsubstancje nieorganiczne, w tym – frakcja wdychalna – frakcja respirabilna – frakcja torakalna\nmetale i ich zwiazki, w tym – frakcja wdychalna – frakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002 + Az1:2004","categories":["materials","environment"],"row_index":583,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for the assessment of occupational exposure to:","parameters_en":[{"name":"asbestos – respirable fibres"},{"name":"refractory ceramic fibres"},{"name":"refractory ceramic fibres mixed with other man-made mineral fibres"},{"name":"man-made mineral fibres, excluding refractory ceramic fibres – respirable fibres"},{"name":"organic substances, including – inhalable fraction"},{"name":"inorganic substances, including – inhalable fraction – respirable fraction – thoracic fraction"},{"name":"metals and their compounds, including – inhalable fraction – respirable fraction"}],"search_en":"Workplace environment – air Sampling for the assessment of occupational exposure to: Personal dosimetry method asbestos – respirable fibres refractory ceramic fibres refractory ceramic fibres mixed with other man-made mineral fibres man-made mineral fibres, excluding refractory ceramic fibres – respirable fibres organic substances, including – inhalable fraction inorganic substances, including – inhalable fraction – respirable fraction – thoracic fraction metals and their compounds, including – inhalable fraction – respirable fraction PN-Z-04008-7:2002 + Az1:2004","technique_en":"Personal dosimetry method","test_object_en":"Workplace environment – air","search_zh":"工作场所环境 — 空气 职业接触评估采样，针对： 个体剂量测定法 石棉 — 呼吸性纤维 耐火陶瓷纤维 与其他人造矿物纤维混合的耐火陶瓷纤维 人造矿物纤维，耐火陶瓷纤维除外 － 呼吸性纤维 有机物质，包括 — 可吸入组分 无机物质，其中包括 － 可吸入性粉尘 － 呼吸性粉尘 － 胸腔性粉尘 金属及其化合物，包括 — 可吸入组分 — 呼吸性组分 PN-Z-04008-7:2002 + Az1:2004","technique_zh":"个体剂量测定法","test_object_zh":"工作场所环境 — 空气","parameters_zh":[{"name":"石棉 — 呼吸性纤维"},{"name":"耐火陶瓷纤维"},{"name":"与其他人造矿物纤维混合的耐火陶瓷纤维"},{"name":"人造矿物纤维，耐火陶瓷纤维除外 － 呼吸性纤维"},{"name":"有机物质，包括 — 可吸入组分"},{"name":"无机物质，其中包括 － 可吸入性粉尘 － 呼吸性粉尘 － 胸腔性粉尘"},{"name":"金属及其化合物，包括 — 可吸入组分 — 呼吸性组分"}],"methodology_zh":"职业接触评估采样，针对："},{"_id":"6a8369ecaf14b9c0e7b1de6a","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Pobieranie próbek w celu oceny narażenia zawodowego na:","parameters":[{"name":"substancje nieorganiczne"}],"technique":"Metoda stacjonarna","techniques":["Metoda stacjonarna"],"computed":[],"activity":"Pobieranie próbek w celu oceny narażenia zawodowego na:\nsubstancje nieorganiczne\nMetoda stacjonarna","reference":"PN-Z-04008-7:2002 + Az1:2004","norm_bases":["PN-Z-04008-7:2002 + Az1:2004"],"lab_section":"Pracownia Środowiskowa, Dział Pomiarów Jakości Środowiska - Stanowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Pobieranie próbek w celu oceny narażenia zawodowego na:\nsubstancje nieorganiczne\nMetoda stacjonarna PN-Z-04008-7:2002 + Az1:2004 Srodowisko pracy – powietrze Pobieranie probek w celu oceny narazenia zawodowego na:\nsubstancje nieorganiczne\nMetoda stacjonarna PN-Z-04008-7:2002 + Az1:2004","categories":["environment"],"row_index":584,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for the assessment of occupational exposure to:","parameters_en":[{"name":"inorganic substances"}],"search_en":"Workplace environment – air Sampling for the assessment of occupational exposure to: Stationary method inorganic substances PN-Z-04008-7:2002 + Az1:2004","technique_en":"Stationary method","test_object_en":"Workplace environment – air","search_zh":"工作场所环境 — 空气 职业接触评估采样，针对： 定点测定法 无机物质 PN-Z-04008-7:2002 + Az1:2004","test_object_zh":"工作场所环境 — 空气","parameters_zh":[{"name":"无机物质"}],"methodology_zh":"职业接触评估采样，针对：","technique_zh":"定点测定法"},{"_id":"6a8369ecaf14b9c0e7b1de6b","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Wskaźnik narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PN-Z-04008-7:2002 + Az1:2004","norm_bases":["PN-Z-04008-7:2002 + Az1:2004"],"lab_section":"Pracownia Środowiskowa, Dział Pomiarów Jakości Środowiska - Stanowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Wskaźnik narażenia (z obliczeń) PN-Z-04008-7:2002 + Az1:2004 Srodowisko pracy – powietrze Wskaznik narazenia (z obliczen) PN-Z-04008-7:2002 + Az1:2004","categories":["environment"],"row_index":585,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Exposure index (calculated)","search_en":"Workplace environment – air Exposure index (calculated) PN-Z-04008-7:2002 + Az1:2004","test_object_en":"Workplace environment – air","methodology_zh":"暴露指数（计算得出）","search_zh":"工作场所环境 — 空气 暴露指数（计算得出） PN-Z-04008-7:2002 + Az1:2004","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a8369ecaf14b9c0e7b1de6c","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna","parameters":[{"name":"Apatyty i fosforyty"},{"name":"Cement portlandzki"},{"name":"Grafit naturalny"},{"name":"Krzemionka bezpostaciowa i syntetyczna"},{"name":"Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Talk"},{"name":"Węgiel (kamienny, brunatny)"},{"name":"Zakres","range":"(0,15 - 17,4) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nTalk\nWęgiel (kamienny, brunatny)\nZakres (0,15 - 17,4) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04508:2022-05","PN-Z-04508:2022-05/Ap1:2022-08"],"lab_section":"Pracownia Środowiskowa, Dział Pomiarów Jakości Środowiska - Stanowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nTalk\nWęgiel (kamienny, brunatny)\nZakres (0,15 - 17,4) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08 Srodowisko pracy – powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia – frakcja respirabilna\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nTalk\nWegiel (kamienny, brunatny)\nZakres (0,15 - 17,4) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":586,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of harmful dust agents – respirable fraction","parameters_en":[{"name":"Apatites and phosphorites"},{"name":"Portland cement"},{"name":"Natural graphite"},{"name":"Amorphous and synthetic silica"},{"name":"Organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"Talc"},{"name":"Coal (hard, brown)"},{"name":"Range","range":"(0,15 - 17,4) mg/m3"}],"search_en":"Workplace environment – air Concentration of harmful dust agents – respirable fraction Gravimetric method Apatites and phosphorites Portland cement Natural graphite Amorphous and synthetic silica Organic dusts of animal and plant origin, excluding wood and flour dusts Talc Coal (hard, brown) Range PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment – air","parameters_zh":[{"name":"磷灰石与磷块岩"},{"name":"硅酸盐水泥"},{"name":"天然石墨"},{"name":"无定形与合成二氧化硅"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"滑石"},{"name":"煤（烟煤、褐煤）"},{"name":"范围","range":"(0,15 - 17,4) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害粉尘因素浓度 — 呼吸性组分 重量法 磷灰石与磷块岩 硅酸盐水泥 天然石墨 无定形与合成二氧化硅 动植物来源有机粉尘，木粉和面粉除外 滑石 煤（烟煤、褐煤） 范围 PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"有害粉尘因素浓度 — 呼吸性组分"},{"_id":"6a8369ecaf14b9c0e7b1de6d","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna","parameters":[{"name":"Apatyty i fosforyty"},{"name":"Cement portlandzki"},{"name":"Ditlenek tytanu"},{"name":"Grafit naturalny"},{"name":"Grafit syntetyczny"},{"name":"Kaolin"},{"name":"Krzemionka bezpostaciowa i syntetyczna"},{"name":"Pyły drewna"},{"name":"Pyły mąki"},{"name":"Pyły niesklasyfikowane ze względu na toksyczność"},{"name":"Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Siarczan (VI) wapnia (gips)"},{"name":"Sadza techniczna"},{"name":"Sztuczne włókna mineralne z wyjątkiem ogniotrwałych włókien ceramicznych"},{"name":"Talk"},{"name":"Węgiel (kamienny, brunatny)"},{"name":"Węglan magnezu wapnia (dolomit)"},{"name":"Węglik krzemu, niewłóknisty"},{"name":"Zakres","range":"(0,17 - 20,4) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna\nZakres:\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna\nPyły drewna\nPyły mąki\nPyły niesklasyfikowane ze względu na toksyczność\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nSztuczne włókna mineralne z wyjątkiem ogniotrwałych włókien ceramicznych\nTalk\nWęgiel (kamienny, brunatny)\nWęglan magnezu wapnia (dolomit)\nWęglik krzemu, niewłóknisty\nZakres (0,17 - 20,4) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04507:2022-05","PN-Z-04507:2022-05/Ap1:2022-08"],"lab_section":"Pracownia Środowiskowa, Dział Pomiarów Jakości Środowiska - Stanowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna\nZakres:\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna\nPyły drewna\nPyły mąki\nPyły niesklasyfikowane ze względu na toksyczność\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nSztuczne włókna mineralne z wyjątkiem ogniotrwałych włókien ceramicznych\nTalk\nWęgiel (kamienny, brunatny)\nWęglan magnezu wapnia (dolomit)\nWęglik krzemu, niewłóknisty\nZakres (0,17 - 20,4) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08 Srodowisko pracy – powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia – frakcja wdychalna\nZakres:\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna\nPyly drewna\nPyly maki\nPyly niesklasyfikowane ze wzgledu na toksycznosc\nPyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nSztuczne wlokna mineralne z wyjatkiem ogniotrwalych wlokien ceramicznych\nTalk\nWegiel (kamienny, brunatny)\nWeglan magnezu wapnia (dolomit)\nWeglik krzemu, niewloknisty\nZakres (0,17 - 20,4) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":587,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of harmful dust agents – inhalable fraction","parameters_en":[{"name":"Apatites and phosphorites"},{"name":"Portland cement"},{"name":"Titanium dioxide"},{"name":"Natural graphite"},{"name":"Synthetic graphite"},{"name":"Kaolin"},{"name":"Amorphous and synthetic silica"},{"name":"Wood dusts"},{"name":"Flour dusts"},{"name":"Dusts not classified according to toxicity"},{"name":"Organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"Calcium sulfate (VI) (gypsum)"},{"name":"Carbon black"},{"name":"Man-made mineral fibres excluding refractory ceramic fibres"},{"name":"Talc"},{"name":"Coal (hard, brown)"},{"name":"Calcium magnesium carbonate (dolomite)"},{"name":"Silicon carbide, non-fibrous"},{"name":"Range","range":"(0,17 - 20,4) mg/m3"}],"search_en":"Workplace environment – air Concentration of harmful dust agents – inhalable fraction Gravimetric method Apatites and phosphorites Portland cement Titanium dioxide Natural graphite Synthetic graphite Kaolin Amorphous and synthetic silica Wood dusts Flour dusts Dusts not classified according to toxicity Organic dusts of animal and plant origin, excluding wood and flour dusts Calcium sulfate (VI) (gypsum) Carbon black Man-made mineral fibres excluding refractory ceramic fibres Talc Coal (hard, brown) Calcium magnesium carbonate (dolomite) Silicon carbide, non-fibrous Range PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment – air","parameters_zh":[{"name":"磷灰石与磷块岩"},{"name":"硅酸盐水泥"},{"name":"二氧化钛"},{"name":"天然石墨"},{"name":"合成石墨"},{"name":"高岭土"},{"name":"无定形与合成二氧化硅"},{"name":"木粉尘"},{"name":"面粉粉尘"},{"name":"未按毒性分类的粉尘"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"硫酸钙（VI）（石膏）"},{"name":"炭黑"},{"name":"人造矿物纤维，耐火陶瓷纤维除外"},{"name":"滑石"},{"name":"煤（烟煤、褐煤）"},{"name":"碳酸钙镁（白云石）"},{"name":"碳化硅，非纤维状"},{"name":"范围","range":"(0,17 - 20,4) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害粉尘因素浓度 — 可吸入组分 重量法 磷灰石与磷块岩 硅酸盐水泥 二氧化钛 天然石墨 合成石墨 高岭土 无定形与合成二氧化硅 木粉尘 面粉粉尘 未按毒性分类的粉尘 动植物来源有机粉尘，木粉和面粉除外 硫酸钙（VI）（石膏） 炭黑 人造矿物纤维，耐火陶瓷纤维除外 滑石 煤（烟煤、褐煤） 碳酸钙镁（白云石） 碳化硅，非纤维状 范围 PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"有害粉尘因素浓度 — 可吸入组分"},{"_id":"6a8369ecaf14b9c0e7b1de6e","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie chloru","parameters":[{"name":"Zakres","range":"(0,07 - 1,4) mg/m3"},{"name":"(z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie chloru\nZakres:\nZakres (0,07 - 1,4) mg/m3\n(z obliczeń)","reference":"PB-SP-01 wersja 03 z dnia 03.02.2025 r. | PN-75/Z-04037-03","norm_bases":["PB-SP-01 wersja 03 z dnia 03.02.2025 r.","PN-75/Z-04037-03"],"lab_section":"Pracownia Środowiskowa, Dział Pomiarów Jakości Środowiska - Stanowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie chloru\nZakres:\nZakres (0,07 - 1,4) mg/m3\n(z obliczeń) PB-SP-01 wersja 03 z dnia 03.02.2025 r. | PN-75/Z-04037-03 Srodowisko pracy – powietrze Stezenie chloru\nZakres:\nZakres (0,07 - 1,4) mg/m3\n(z obliczen) PB-SP-01 wersja 03 z dnia 03.02.2025 r. | PN-75/Z-04037-03","categories":["environment"],"row_index":588,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chlorine concentration","parameters_en":[{"name":"Range","range":"(0,07 - 1,4) mg/m3"},{"name":"(calculated)"}],"search_en":"Workplace environment – air Chlorine concentration Range (calculated) PB-SP-01 wersja 03 z dnia 03.02.2025 r. | PN-75/Z-04037-03","test_object_en":"Workplace environment – air","parameters_zh":[{"name":"范围","range":"(0,07 - 1,4) mg/m3"},{"name":"（计算得出）"}],"search_zh":"工作场所环境 — 空气 氯浓度 范围 （计算得出） PB-SP-01 wersja 03 z dnia 03.02.2025 r. | PN-75/Z-04037-03","test_object_zh":"工作场所环境 — 空气","methodology_zh":"氯浓度"},{"_id":"6a8369ecaf14b9c0e7b1de6f","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie gazów","parameters":[{"name":"CO","range":"(2,3 - 230) mg/m3"},{"name":"NO","range":"(0,26 - 12,4) mg/m3"},{"name":"NO2","range":"(0,20 - 3,8) mg/m3"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Stężenie gazów\nZakres:\nCO (2,3 - 230) mg/m3\nNO (0,26 - 12,4) mg/m3\nNO2 (0,20 - 3,8) mg/m3\nMetoda elektrochemiczna","reference":"PB-SP-02 wersja 01 z dnia 22.02.2021 r.","norm_bases":["PB-SP-02 wersja 01 z dnia 22.02.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Pomiarów Jakości Środowiska - Stanowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie gazów\nZakres:\nCO (2,3 - 230) mg/m3\nNO (0,26 - 12,4) mg/m3\nNO2 (0,20 - 3,8) mg/m3\nMetoda elektrochemiczna PB-SP-02 wersja 01 z dnia 22.02.2021 r. Srodowisko pracy – powietrze Stezenie gazow\nZakres:\nCO (2,3 - 230) mg/m3\nNO (0,26 - 12,4) mg/m3\nNO2 (0,20 - 3,8) mg/m3\nMetoda elektrochemiczna PB-SP-02 wersja 01 z dnia 22.02.2021 r.","categories":["environment"],"row_index":589,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gas concentrations","parameters_en":[{"name":"CO","range":"(2,3 - 230) mg/m3"},{"name":"NO","range":"(0,26 - 12,4) mg/m3"},{"name":"NO2","range":"(0,20 - 3,8) mg/m3"}],"search_en":"Workplace environment – air Gas concentrations Electrochemical method CO NO NO2 PB-SP-02 wersja 01 z dnia 22.02.2021 r.","technique_en":"Electrochemical method","test_object_en":"Workplace environment – air","search_zh":"工作场所环境 — 空气 气体浓度 电化学法 CO NO NO2 PB-SP-02 wersja 01 z dnia 22.02.2021 r.","technique_zh":"电化学法","test_object_zh":"工作场所环境 — 空气","parameters_zh":[{"name":"CO","range":"(2,3 - 230) mg/m3"},{"name":"NO","range":"(0,26 - 12,4) mg/m3"},{"name":"NO2","range":"(0,20 - 3,8) mg/m3"}],"methodology_zh":"气体浓度"},{"_id":"6a8369ecaf14b9c0e7b1de70","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Wskaźniki narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźniki narażenia (z obliczeń)","reference":"PB-SP-02 wersja 01 z dnia 22.02.2021 r.","norm_bases":["PB-SP-02 wersja 01 z dnia 22.02.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Pomiarów Jakości Środowiska - Stanowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Wskaźniki narażenia (z obliczeń) PB-SP-02 wersja 01 z dnia 22.02.2021 r. Srodowisko pracy – powietrze Wskazniki narazenia (z obliczen) PB-SP-02 wersja 01 z dnia 22.02.2021 r.","categories":["environment"],"row_index":590,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Exposure indices (calculated)","search_en":"Workplace environment – air Exposure indices (calculated) PB-SP-02 wersja 01 z dnia 22.02.2021 r.","test_object_en":"Workplace environment – air","search_zh":"工作场所环境 — 空气 暴露指数（计算值） PB-SP-02 wersja 01 z dnia 22.02.2021 r.","test_object_zh":"工作场所环境 — 空气","methodology_zh":"暴露指数（计算值）"},{"_id":"6a8369ecaf14b9c0e7b1de71","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie formaldehydu","parameters":[{"name":"Zakres","range":"(0,028 - 5,55) mg/m3"},{"name":"(z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie formaldehydu\nZakres:\nZakres (0,028 - 5,55) mg/m3\n(z obliczeń)","reference":"PB-SP-01 wersja 03 z dnia 03.02.2025 r. | PB-DAO-02 wersja 01 z dnia 23.02.2021 r.","norm_bases":["PB-SP-01 wersja 03 z dnia 03.02.2025 r.","PB-DAO-02 wersja 01 z dnia 23.02.2021 r."],"lab_section":"Pracownia Środowiskowa, Dział Pomiarów Jakości Środowiska - Stanowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie formaldehydu\nZakres:\nZakres (0,028 - 5,55) mg/m3\n(z obliczeń) PB-SP-01 wersja 03 z dnia 03.02.2025 r. | PB-DAO-02 wersja 01 z dnia 23.02.2021 r. Srodowisko pracy – powietrze Stezenie formaldehydu\nZakres:\nZakres (0,028 - 5,55) mg/m3\n(z obliczen) PB-SP-01 wersja 03 z dnia 03.02.2025 r. | PB-DAO-02 wersja 01 z dnia 23.02.2021 r.","categories":["environment"],"row_index":591,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Formaldehyde concentration","parameters_en":[{"name":"Range","range":"(0,028 - 5,55) mg/m3"},{"name":"(calculated)"}],"search_en":"Workplace environment – air Formaldehyde concentration Range (calculated) PB-SP-01 wersja 03 z dnia 03.02.2025 r. | PB-DAO-02 wersja 01 z dnia 23.02.2021 r.","test_object_en":"Workplace environment – air","parameters_zh":[{"name":"范围","range":"(0,028 - 5,55) mg/m3"},{"name":"（计算得出）"}],"search_zh":"工作场所环境 — 空气 甲醛浓度 范围 （计算得出） PB-SP-01 wersja 03 z dnia 03.02.2025 r. | PB-DAO-02 wersja 01 z dnia 23.02.2021 r.","test_object_zh":"工作场所环境 — 空气","methodology_zh":"甲醛浓度"},{"_id":"6a8369ecaf14b9c0e7b1de72","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie krystalicznej krzemionki (kwarc, krystobalit) – frakcja respirabilna","parameters":[{"name":"Zakres","range":"(0,006 - 0,50) mg/m3"},{"name":"(z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie krystalicznej krzemionki (kwarc, krystobalit) – frakcja respirabilna\nZakres:\nZakres (0,006 - 0,50) mg/m3\n(z obliczeń)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2012, nr 4(74) s. 117-130 | PB-DAN-03 wersja 01 z dnia 31.01.2020 r. | PB-SP-01 wersja 03 z dnia 03.02.2025 r.","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2012, nr 4(74) s. 117-130","PB-DAN-03 wersja 01 z dnia 31.01.2020 r.","PB-SP-01 wersja 03 z dnia 03.02.2025 r."],"lab_section":"Pracownia Środowiskowa, Dział Pomiarów Jakości Środowiska - Stanowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie krystalicznej krzemionki (kwarc, krystobalit) – frakcja respirabilna\nZakres:\nZakres (0,006 - 0,50) mg/m3\n(z obliczeń) Podstawy i Metody Oceny Środowiska Pracy 2012, nr 4(74) s. 117-130 | PB-DAN-03 wersja 01 z dnia 31.01.2020 r. | PB-SP-01 wersja 03 z dnia 03.02.2025 r. Srodowisko pracy – powietrze Stezenie krystalicznej krzemionki (kwarc, krystobalit) – frakcja respirabilna\nZakres:\nZakres (0,006 - 0,50) mg/m3\n(z obliczen) Podstawy i Metody Oceny Srodowiska Pracy 2012, nr 4(74) s. 117-130 | PB-DAN-03 wersja 01 z dnia 31.01.2020 r. | PB-SP-01 wersja 03 z dnia 03.02.2025 r.","categories":["environment"],"row_index":592,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Crystalline silica (quartz, cristobalite) concentration – respirable fraction","parameters_en":[{"name":"Range","range":"(0,006 - 0,50) mg/m3"},{"name":"(calculated)"}],"search_en":"Workplace environment – air Crystalline silica (quartz, cristobalite) concentration – respirable fraction Range (calculated) Podstawy i Metody Oceny Środowiska Pracy 2012, nr 4(74) s. 117-130 | PB-DAN-03 wersja 01 z dnia 31.01.2020 r. | PB-SP-01 wersja 03 z dnia 03.02.2025 r.","test_object_en":"Workplace environment – air","parameters_zh":[{"name":"范围","range":"(0,006 - 0,50) mg/m3"},{"name":"（计算得出）"}],"search_zh":"工作场所环境 — 空气 结晶二氧化硅（石英、方石英）浓度 － 呼吸性粉尘 范围 （计算得出） Podstawy i Metody Oceny Środowiska Pracy 2012, nr 4(74) s. 117-130 | PB-DAN-03 wersja 01 z dnia 31.01.2020 r. | PB-SP-01 wersja 03 z dnia 03.02.2025 r.","test_object_zh":"工作场所环境 — 空气","methodology_zh":"结晶二氧化硅（石英、方石英）浓度 － 呼吸性粉尘"},{"_id":"6a8369ecaf14b9c0e7b1de73","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie pierwiastków i ich związków","parameters":[{"name":"Glin metaliczny, glin proszek (niestabilizowany), Tritlenek glinu w przeliczeniu na Al Wodorotlenek glinu w przeliczeniu na Al – frakcja wdychalna"},{"name":"Zakres","range":"(0,014 - 6,94) mg/m3"},{"name":"frakcja respirabilna","range":"(0,013 - 6,25) mg/m3"},{"name":"Chrom metaliczny Związki chromu (II) – w przeliczeniu na Cr(II) Związki chromu (III) – w przeliczeniu na Cr(III)","range":"(0,007 - 1,38) mg/m3"},{"name":"Mangan i jego związki nieorganiczne – w przeliczeniu na Mn – frakcja wdychalna","range":"(0,0035 - 0,55) mg/m3"},{"name":"frakcja respirabilna","range":"(0,0032 - 0,58) mg/m3"},{"name":"Tlenki żelaza – w przeliczeniu na Fe Tlenek żelaza(III), Tlenek żelaza(II), Tetratlenek triżelaza – frakcja wdychalna","range":"(0,028 - 13,8) mg/m3"},{"name":"frakcja respirabilna","range":"(0,025 - 12,5) mg/m3"},{"name":"Kobalt i jego związki nieorganiczne"},{"name":"w przeliczeniu na Co","range":"(0,0014 - 0,069) mg/m3"},{"name":"Nikiel metaliczny","range":"(0,0008 - 0,69) mg/m3"},{"name":"Związki niklu – w przeliczeniu na Ni – frakcja wdychalna","range":"(0,0008 - 0,69) mg/m3"},{"name":"frakcja respirabilna","range":"(0,0008 - 0,69) mg/m3"},{"name":"Miedź i jej związki nieorganiczne - w przeliczeniu na Cu","range":"(0,007 – 1,38) mg/m3"},{"name":"Tlenek cynku - w przeliczeniu na Zn – frakcja wdychalna","range":"(0,014 - 13,8) mg/m3"},{"name":"Arsen i jego związki nieorganiczne"},{"name":"w przeliczeniu na As – frakcja wdychalna","range":"(0,00069 - 0,69) mg/m3"},{"name":"Selen i jego związki, z wyjątkiem selanu - w przeliczeniu na Se","range":"(0,0069 - 0,69) mg/m3"},{"name":"Molibden i jego związki - w przeliczeniu na Mo","range":"(0,028 - 8,33) mg/m3"},{"name":"(z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie pierwiastków i ich związków\nZakres:\nGlin metaliczny, glin proszek (niestabilizowany), Tritlenek glinu w przeliczeniu na Al Wodorotlenek glinu w przeliczeniu na Al – frakcja wdychalna\nZakres (0,014 - 6,94) mg/m3\nfrakcja respirabilna (0,013 - 6,25) mg/m3\nChrom metaliczny Związki chromu (II) – w przeliczeniu na Cr(II) Związki chromu (III) – w przeliczeniu na Cr(III) (0,007 - 1,38) mg/m3\nMangan i jego związki nieorganiczne – w przeliczeniu na Mn – frakcja wdychalna (0,0035 - 0,55) mg/m3\nfrakcja respirabilna (0,0032 - 0,58) mg/m3\nTlenki żelaza – w przeliczeniu na Fe Tlenek żelaza(III), Tlenek żelaza(II), Tetratlenek triżelaza – frakcja wdychalna (0,028 - 13,8) mg/m3\nfrakcja respirabilna (0,025 - 12,5) mg/m3\nKobalt i jego związki nieorganiczne\nw przeliczeniu na Co (0,0014 - 0,069) mg/m3\nNikiel metaliczny (0,0008 - 0,69) mg/m3\nZwiązki niklu – w przeliczeniu na Ni – frakcja wdychalna (0,0008 - 0,69) mg/m3\nfrakcja respirabilna (0,0008 - 0,69) mg/m3\nMiedź i jej związki nieorganiczne - w przeliczeniu na Cu (0,007 – 1,38) mg/m3\nTlenek cynku - w przeliczeniu na Zn – frakcja wdychalna (0,014 - 13,8) mg/m3\nArsen i jego związki nieorganiczne\nw przeliczeniu na As – frakcja wdychalna (0,00069 - 0,69) mg/m3\nSelen i jego związki, z wyjątkiem selanu - w przeliczeniu na Se (0,0069 - 0,69) mg/m3\nMolibden i jego związki - w przeliczeniu na Mo (0,028 - 8,33) mg/m3\n(z obliczeń)","reference":"ISO 15202-2:2020-05 | ISO 30011:2010 | PB-SP-01 wersja 03 z dnia 03.02.2025 r.","norm_bases":["ISO 15202-2:2020-05","ISO 30011:2010","PB-SP-01 wersja 03 z dnia 03.02.2025 r."],"lab_section":"Pracownia Środowiskowa, Dział Pomiarów Jakości Środowiska - Stanowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie pierwiastków i ich związków\nZakres:\nGlin metaliczny, glin proszek (niestabilizowany), Tritlenek glinu w przeliczeniu na Al Wodorotlenek glinu w przeliczeniu na Al – frakcja wdychalna\nZakres (0,014 - 6,94) mg/m3\nfrakcja respirabilna (0,013 - 6,25) mg/m3\nChrom metaliczny Związki chromu (II) – w przeliczeniu na Cr(II) Związki chromu (III) – w przeliczeniu na Cr(III) (0,007 - 1,38) mg/m3\nMangan i jego związki nieorganiczne – w przeliczeniu na Mn – frakcja wdychalna (0,0035 - 0,55) mg/m3\nfrakcja respirabilna (0,0032 - 0,58) mg/m3\nTlenki żelaza – w przeliczeniu na Fe Tlenek żelaza(III), Tlenek żelaza(II), Tetratlenek triżelaza – frakcja wdychalna (0,028 - 13,8) mg/m3\nfrakcja respirabilna (0,025 - 12,5) mg/m3\nKobalt i jego związki nieorganiczne\nw przeliczeniu na Co (0,0014 - 0,069) mg/m3\nNikiel metaliczny (0,0008 - 0,69) mg/m3\nZwiązki niklu – w przeliczeniu na Ni – frakcja wdychalna (0,0008 - 0,69) mg/m3\nfrakcja respirabilna (0,0008 - 0,69) mg/m3\nMiedź i jej związki nieorganiczne - w przeliczeniu na Cu (0,007 – 1,38) mg/m3\nTlenek cynku - w przeliczeniu na Zn – frakcja wdychalna (0,014 - 13,8) mg/m3\nArsen i jego związki nieorganiczne\nw przeliczeniu na As – frakcja wdychalna (0,00069 - 0,69) mg/m3\nSelen i jego związki, z wyjątkiem selanu - w przeliczeniu na Se (0,0069 - 0,69) mg/m3\nMolibden i jego związki - w przeliczeniu na Mo (0,028 - 8,33) mg/m3\n(z obliczeń) ISO 15202-2:2020-05 | ISO 30011:2010 | PB-SP-01 wersja 03 z dnia 03.02.2025 r. Srodowisko pracy – powietrze Stezenie pierwiastkow i ich zwiazkow\nZakres:\nGlin metaliczny, glin proszek (niestabilizowany), Tritlenek glinu w przeliczeniu na Al Wodorotlenek glinu w przeliczeniu na Al – frakcja wdychalna\nZakres (0,014 - 6,94) mg/m3\nfrakcja respirabilna (0,013 - 6,25) mg/m3\nChrom metaliczny Zwiazki chromu (II) – w przeliczeniu na Cr(II) Zwiazki chromu (III) – w przeliczeniu na Cr(III) (0,007 - 1,38) mg/m3\nMangan i jego zwiazki nieorganiczne – w przeliczeniu na Mn – frakcja wdychalna (0,0035 - 0,55) mg/m3\nfrakcja respirabilna (0,0032 - 0,58) mg/m3\nTlenki zelaza – w przeliczeniu na Fe Tlenek zelaza(III), Tlenek zelaza(II), Tetratlenek trizelaza – frakcja wdychalna (0,028 - 13,8) mg/m3\nfrakcja respirabilna (0,025 - 12,5) mg/m3\nKobalt i jego zwiazki nieorganiczne\nw przeliczeniu na Co (0,0014 - 0,069) mg/m3\nNikiel metaliczny (0,0008 - 0,69) mg/m3\nZwiazki niklu – w przeliczeniu na Ni – frakcja wdychalna (0,0008 - 0,69) mg/m3\nfrakcja respirabilna (0,0008 - 0,69) mg/m3\nMiedz i jej zwiazki nieorganiczne - w przeliczeniu na Cu (0,007 – 1,38) mg/m3\nTlenek cynku - w przeliczeniu na Zn – frakcja wdychalna (0,014 - 13,8) mg/m3\nArsen i jego zwiazki nieorganiczne\nw przeliczeniu na As – frakcja wdychalna (0,00069 - 0,69) mg/m3\nSelen i jego zwiazki, z wyjatkiem selanu - w przeliczeniu na Se (0,0069 - 0,69) mg/m3\nMolibden i jego zwiazki - w przeliczeniu na Mo (0,028 - 8,33) mg/m3\n(z obliczen) ISO 15202-2:2020-05 | ISO 30011:2010 | PB-SP-01 wersja 03 z dnia 03.02.2025 r.","categories":["materials","environment"],"row_index":593,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of elements and their compounds","parameters_en":[{"name":"Metallic aluminium, aluminium powder (non-stabilised), Aluminium trioxide expressed as Al Aluminium hydroxide expressed as Al – inhalable fraction"},{"name":"Range","range":"(0,014 - 6,94) mg/m3"},{"name":"respirable fraction","range":"(0,013 - 6,25) mg/m3"},{"name":"Metallic chromium Chromium (II) compounds – expressed as Cr(II) Chromium (III) compounds – expressed as Cr(III)","range":"(0,007 - 1,38) mg/m3"},{"name":"Manganese and its inorganic compounds – expressed as Mn – inhalable fraction","range":"(0,0035 - 0,55) mg/m3"},{"name":"respirable fraction","range":"(0,0032 - 0,58) mg/m3"},{"name":"Iron oxides – calculated as Fe Iron(III) oxide, Iron(II) oxide, Triiron tetraoxide – inhalable fraction","range":"(0,028 - 13,8) mg/m3"},{"name":"respirable fraction","range":"(0,025 - 12,5) mg/m3"},{"name":"Cobalt and its inorganic compounds"},{"name":"expressed as Co","range":"(0,0014 - 0,069) mg/m3"},{"name":"Metallic nickel","range":"(0,0008 - 0,69) mg/m3"},{"name":"Nickel compounds – calculated as Ni – inhalable fraction","range":"(0,0008 - 0,69) mg/m3"},{"name":"respirable fraction","range":"(0,0008 - 0,69) mg/m3"},{"name":"Copper and its inorganic compounds - expressed as Cu","range":"(0,007 – 1,38) mg/m3"},{"name":"Zinc oxide - calculated as Zn – inhalable fraction","range":"(0,014 - 13,8) mg/m3"},{"name":"Arsenic and its inorganic compounds"},{"name":"calculated as As – inhalable fraction","range":"(0,00069 - 0,69) mg/m3"},{"name":"Selenium and its compounds, excluding selane - calculated as Se","range":"(0,0069 - 0,69) mg/m3"},{"name":"Molybdenum and its compounds - expressed as Mo","range":"(0,028 - 8,33) mg/m3"},{"name":"(calculated)"}],"search_en":"Workplace environment – air Concentration of elements and their compounds Metallic aluminium, aluminium powder (non-stabilised), Aluminium trioxide expressed as Al Aluminium hydroxide expressed as Al – inhalable fraction Range respirable fraction Metallic chromium Chromium (II) compounds – expressed as Cr(II) Chromium (III) compounds – expressed as Cr(III) Manganese and its inorganic compounds – expressed as Mn – inhalable fraction respirable fraction Iron oxides – calculated as Fe Iron(III) oxide, Iron(II) oxide, Triiron tetraoxide – inhalable fraction respirable fraction Cobalt and its inorganic compounds expressed as Co Metallic nickel Nickel compounds – calculated as Ni – inhalable fraction respirable fraction Copper and its inorganic compounds - expressed as Cu Zinc oxide - calculated as Zn – inhalable fraction Arsenic and its inorganic compounds calculated as As – inhalable fraction Selenium and its compounds, excluding selane - calculated as Se Molybdenum and its compounds - expressed as Mo (calculated) ISO 15202-2:2020-05 | ISO 30011:2010 | PB-SP-01 wersja 03 z dnia 03.02.2025 r.","test_object_en":"Workplace environment – air","parameters_zh":[{"name":"Glin metaliczny, glin proszek (niestabilizowany), Tritlenek glinu w przeliczeniu na Al Wodorotlenek glinu w przeliczeniu na Al – frakcja wdychalna"},{"name":"范围","range":"(0,014 - 6,94) mg/m3"},{"name":"呼吸性组分","range":"(0,013 - 6,25) mg/m3"},{"name":"Chrom metaliczny Związki chromu (II) – w przeliczeniu na Cr(II) Związki chromu (III) – w przeliczeniu na Cr(III)","range":"(0,007 - 1,38) mg/m3"},{"name":"Mangan i jego związki nieorganiczne – w przeliczeniu na Mn – frakcja wdychalna","range":"(0,0035 - 0,55) mg/m3"},{"name":"呼吸性组分","range":"(0,0032 - 0,58) mg/m3"},{"name":"Tlenki żelaza – w przeliczeniu na Fe Tlenek żelaza(III), Tlenek żelaza(II), Tetratlenek triżelaza – frakcja wdychalna","range":"(0,028 - 13,8) mg/m3"},{"name":"呼吸性组分","range":"(0,025 - 12,5) mg/m3"},{"name":"Kobalt i jego związki nieorganiczne"},{"name":"w przeliczeniu na Co","range":"(0,0014 - 0,069) mg/m3"},{"name":"Nikiel metaliczny","range":"(0,0008 - 0,69) mg/m3"},{"name":"Związki niklu – w przeliczeniu na Ni – frakcja wdychalna","range":"(0,0008 - 0,69) mg/m3"},{"name":"呼吸性组分","range":"(0,0008 - 0,69) mg/m3"},{"name":"Miedź i jej związki nieorganiczne - w przeliczeniu na Cu","range":"(0,007 – 1,38) mg/m3"},{"name":"Tlenek cynku - w przeliczeniu na Zn – frakcja wdychalna","range":"(0,014 - 13,8) mg/m3"},{"name":"Arsen i jego związki nieorganiczne"},{"name":"w przeliczeniu na As – frakcja wdychalna","range":"(0,00069 - 0,69) mg/m3"},{"name":"Selen i jego związki, z wyjątkiem selanu - w przeliczeniu na Se","range":"(0,0069 - 0,69) mg/m3"},{"name":"Molibden i jego związki - w przeliczeniu na Mo","range":"(0,028 - 8,33) mg/m3"},{"name":"（计算得出）"}],"search_zh":"工作场所环境 — 空气 范围 呼吸性组分 呼吸性组分 呼吸性组分 呼吸性组分 （计算得出） ISO 15202-2:2020-05 | ISO 30011:2010 | PB-SP-01 wersja 03 z dnia 03.02.2025 r.","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a8369ecaf14b9c0e7b1de74","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie pierwiastków i ich związków","parameters":[{"name":"Srebro – frakcja wdychalna"},{"name":"Zakres","range":"(0,0007 - 0,13) mg/m3"},{"name":"Kadm i jego związki nieorganiczne – w przeliczeniu na Cd – frakcja wdychalna","range":"(0,00014 - 0,069) mg/m3"},{"name":"frakcja respirabilna","range":"(0,00013 - 0,063) mg/m3"},{"name":"Cyna i jej związki nieorganiczne, z wyjątkiem stannanu - w przeliczeniu na Sn – frakcja wdychalna","range":"(0,014 - 4,16) mg/m3"},{"name":"Bar i jego związki rozpuszczalne - w przeliczeniu na Ba","range":"(0,014 - 1,38) mg/m3"},{"name":"Tal i jego związki - w przeliczeniu na Tl","range":"(0,007 - 0,34) mg/m3"},{"name":"Ołów i jego związki nieorganiczne - w przeliczeniu na Pb – frakcja wdychalna","range":"(0,0035 - 0,13) mg/m3"},{"name":"Wodorotlenek sodu","range":"(0,025 - 1,20) mg/m3"},{"name":"Wodorotlenek potasu","range":"(0,020 - 1,99) mg/m3"},{"name":"Tlenek magnezu – frakcja wdychlna","range":"(0,024 - 23,0) mg/m3"},{"name":"Pentatlenek wanadu – frakcja wdychalna","range":"(0,0025 - 0,24) mg/m3"},{"name":"Tlenek wapnia – frakcja wdychalna","range":"(0,049 - 5,82) mg/m3"},{"name":"frakcja respisabilna","range":"(0,044 - 5,24) mg/m3"},{"name":"Wodorotlenek wapnia – frakcja wdychalna","range":"(0,090 - 10,7) mg/m3"},{"name":"frakcja respirabilna","range":"(0,081 - 9,70) mg/m3"},{"name":"(z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie pierwiastków i ich związków\nZakres:\nSrebro – frakcja wdychalna\nZakres (0,0007 - 0,13) mg/m3\nKadm i jego związki nieorganiczne – w przeliczeniu na Cd – frakcja wdychalna (0,00014 - 0,069) mg/m3\nfrakcja respirabilna (0,00013 - 0,063) mg/m3\nCyna i jej związki nieorganiczne, z wyjątkiem stannanu - w przeliczeniu na Sn – frakcja wdychalna (0,014 - 4,16) mg/m3\nBar i jego związki rozpuszczalne - w przeliczeniu na Ba (0,014 - 1,38) mg/m3\nTal i jego związki - w przeliczeniu na Tl (0,007 - 0,34) mg/m3\nOłów i jego związki nieorganiczne - w przeliczeniu na Pb – frakcja wdychalna (0,0035 - 0,13) mg/m3\nWodorotlenek sodu (0,025 - 1,20) mg/m3\nWodorotlenek potasu (0,020 - 1,99) mg/m3\nTlenek magnezu – frakcja wdychlna (0,024 - 23,0) mg/m3\nPentatlenek wanadu – frakcja wdychalna (0,0025 - 0,24) mg/m3\nTlenek wapnia – frakcja wdychalna (0,049 - 5,82) mg/m3\nfrakcja respisabilna (0,044 - 5,24) mg/m3\nWodorotlenek wapnia – frakcja wdychalna (0,090 - 10,7) mg/m3\nfrakcja respirabilna (0,081 - 9,70) mg/m3\n(z obliczeń)","reference":"ISO 15202-2:2020-05 | ISO 30011:2010 | PB-SP-01 wersja 03 z dnia 03.02.2025 r.","norm_bases":["ISO 15202-2:2020-05","ISO 30011:2010","PB-SP-01 wersja 03 z dnia 03.02.2025 r."],"lab_section":"Pracownia Środowiskowa, Dział Pomiarów Jakości Środowiska - Stanowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie pierwiastków i ich związków\nZakres:\nSrebro – frakcja wdychalna\nZakres (0,0007 - 0,13) mg/m3\nKadm i jego związki nieorganiczne – w przeliczeniu na Cd – frakcja wdychalna (0,00014 - 0,069) mg/m3\nfrakcja respirabilna (0,00013 - 0,063) mg/m3\nCyna i jej związki nieorganiczne, z wyjątkiem stannanu - w przeliczeniu na Sn – frakcja wdychalna (0,014 - 4,16) mg/m3\nBar i jego związki rozpuszczalne - w przeliczeniu na Ba (0,014 - 1,38) mg/m3\nTal i jego związki - w przeliczeniu na Tl (0,007 - 0,34) mg/m3\nOłów i jego związki nieorganiczne - w przeliczeniu na Pb – frakcja wdychalna (0,0035 - 0,13) mg/m3\nWodorotlenek sodu (0,025 - 1,20) mg/m3\nWodorotlenek potasu (0,020 - 1,99) mg/m3\nTlenek magnezu – frakcja wdychlna (0,024 - 23,0) mg/m3\nPentatlenek wanadu – frakcja wdychalna (0,0025 - 0,24) mg/m3\nTlenek wapnia – frakcja wdychalna (0,049 - 5,82) mg/m3\nfrakcja respisabilna (0,044 - 5,24) mg/m3\nWodorotlenek wapnia – frakcja wdychalna (0,090 - 10,7) mg/m3\nfrakcja respirabilna (0,081 - 9,70) mg/m3\n(z obliczeń) ISO 15202-2:2020-05 | ISO 30011:2010 | PB-SP-01 wersja 03 z dnia 03.02.2025 r. Srodowisko pracy – powietrze Stezenie pierwiastkow i ich zwiazkow\nZakres:\nSrebro – frakcja wdychalna\nZakres (0,0007 - 0,13) mg/m3\nKadm i jego zwiazki nieorganiczne – w przeliczeniu na Cd – frakcja wdychalna (0,00014 - 0,069) mg/m3\nfrakcja respirabilna (0,00013 - 0,063) mg/m3\nCyna i jej zwiazki nieorganiczne, z wyjatkiem stannanu - w przeliczeniu na Sn – frakcja wdychalna (0,014 - 4,16) mg/m3\nBar i jego zwiazki rozpuszczalne - w przeliczeniu na Ba (0,014 - 1,38) mg/m3\nTal i jego zwiazki - w przeliczeniu na Tl (0,007 - 0,34) mg/m3\nOlow i jego zwiazki nieorganiczne - w przeliczeniu na Pb – frakcja wdychalna (0,0035 - 0,13) mg/m3\nWodorotlenek sodu (0,025 - 1,20) mg/m3\nWodorotlenek potasu (0,020 - 1,99) mg/m3\nTlenek magnezu – frakcja wdychlna (0,024 - 23,0) mg/m3\nPentatlenek wanadu – frakcja wdychalna (0,0025 - 0,24) mg/m3\nTlenek wapnia – frakcja wdychalna (0,049 - 5,82) mg/m3\nfrakcja respisabilna (0,044 - 5,24) mg/m3\nWodorotlenek wapnia – frakcja wdychalna (0,090 - 10,7) mg/m3\nfrakcja respirabilna (0,081 - 9,70) mg/m3\n(z obliczen) ISO 15202-2:2020-05 | ISO 30011:2010 | PB-SP-01 wersja 03 z dnia 03.02.2025 r.","categories":["environment"],"row_index":594,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of elements and their compounds","parameters_en":[{"name":"Silver – inhalable fraction"},{"name":"Range","range":"(0,0007 - 0,13) mg/m3"},{"name":"Cadmium and its inorganic compounds – expressed as Cd – inhalable fraction","range":"(0,00014 - 0,069) mg/m3"},{"name":"respirable fraction","range":"(0,00013 - 0,063) mg/m3"},{"name":"Tin and its inorganic compounds, excluding stannane - expressed as Sn – inhalable fraction","range":"(0,014 - 4,16) mg/m3"},{"name":"Barium and its soluble compounds - expressed as Ba","range":"(0,014 - 1,38) mg/m3"},{"name":"Thallium and its compounds - calculated as Tl","range":"(0,007 - 0,34) mg/m3"},{"name":"Lead and its inorganic compounds - expressed as Pb – inhalable fraction","range":"(0,0035 - 0,13) mg/m3"},{"name":"Sodium hydroxide","range":"(0,025 - 1,20) mg/m3"},{"name":"Potassium hydroxide","range":"(0,020 - 1,99) mg/m3"},{"name":"Magnesium oxide – inhalable fraction","range":"(0,024 - 23,0) mg/m3"},{"name":"Vanadium pentoxide – inhalable fraction","range":"(0,0025 - 0,24) mg/m3"},{"name":"Calcium oxide – inhalable fraction","range":"(0,049 - 5,82) mg/m3"},{"name":"respirable fraction","range":"(0,044 - 5,24) mg/m3"},{"name":"Calcium hydroxide – inhalable fraction","range":"(0,090 - 10,7) mg/m3"},{"name":"respirable fraction","range":"(0,081 - 9,70) mg/m3"},{"name":"(calculated)"}],"search_en":"Workplace environment – air Concentration of elements and their compounds Silver – inhalable fraction Range Cadmium and its inorganic compounds – expressed as Cd – inhalable fraction respirable fraction Tin and its inorganic compounds, excluding stannane - expressed as Sn – inhalable fraction Barium and its soluble compounds - expressed as Ba Thallium and its compounds - calculated as Tl Lead and its inorganic compounds - expressed as Pb – inhalable fraction Sodium hydroxide Potassium hydroxide Magnesium oxide – inhalable fraction Vanadium pentoxide – inhalable fraction Calcium oxide – inhalable fraction respirable fraction Calcium hydroxide – inhalable fraction respirable fraction (calculated) ISO 15202-2:2020-05 | ISO 30011:2010 | PB-SP-01 wersja 03 z dnia 03.02.2025 r.","test_object_en":"Workplace environment – air","parameters_zh":[{"name":"Srebro – frakcja wdychalna"},{"name":"范围","range":"(0,0007 - 0,13) mg/m3"},{"name":"Kadm i jego związki nieorganiczne – w przeliczeniu na Cd – frakcja wdychalna","range":"(0,00014 - 0,069) mg/m3"},{"name":"呼吸性组分","range":"(0,00013 - 0,063) mg/m3"},{"name":"Cyna i jej związki nieorganiczne, z wyjątkiem stannanu - w przeliczeniu na Sn – frakcja wdychalna","range":"(0,014 - 4,16) mg/m3"},{"name":"Bar i jego związki rozpuszczalne - w przeliczeniu na Ba","range":"(0,014 - 1,38) mg/m3"},{"name":"Tal i jego związki - w przeliczeniu na Tl","range":"(0,007 - 0,34) mg/m3"},{"name":"Ołów i jego związki nieorganiczne - w przeliczeniu na Pb – frakcja wdychalna","range":"(0,0035 - 0,13) mg/m3"},{"name":"Wodorotlenek sodu","range":"(0,025 - 1,20) mg/m3"},{"name":"Wodorotlenek potasu","range":"(0,020 - 1,99) mg/m3"},{"name":"Tlenek magnezu – frakcja wdychlna","range":"(0,024 - 23,0) mg/m3"},{"name":"Pentatlenek wanadu – frakcja wdychalna","range":"(0,0025 - 0,24) mg/m3"},{"name":"Tlenek wapnia – frakcja wdychalna","range":"(0,049 - 5,82) mg/m3"},{"name":"frakcja respisabilna","range":"(0,044 - 5,24) mg/m3"},{"name":"Wodorotlenek wapnia – frakcja wdychalna","range":"(0,090 - 10,7) mg/m3"},{"name":"呼吸性组分","range":"(0,081 - 9,70) mg/m3"},{"name":"（计算得出）"}],"search_zh":"工作场所环境 — 空气 范围 呼吸性组分 呼吸性组分 （计算得出） ISO 15202-2:2020-05 | ISO 30011:2010 | PB-SP-01 wersja 03 z dnia 03.02.2025 r.","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a8369ecaf14b9c0e7b1de75","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Środowisko pracy – oświetlenie elektryczne we wnętrzach","methodology":"Natężenie oświetlenia","parameters":[{"name":"Zakres","range":"(0,5 - 10000) lx"},{"name":"Równomierność oświetlenia (z obliczeń)"}],"technique":"Metoda bezpośredniego pomiaru","techniques":["Metoda bezpośredniego pomiaru"],"computed":[],"activity":"Natężenie oświetlenia\nZakres:\nZakres (0,5 - 10000) lx\nRównomierność oświetlenia (z obliczeń)\nMetoda bezpośredniego pomiaru","reference":"PB-SP-03 wersja 02 z dnia 04.03.2024 r.","norm_bases":["PB-SP-03 wersja 02 z dnia 04.03.2024 r."],"lab_section":"Pracownia Środowiskowa, Dział Pomiarów Jakości Środowiska - Stanowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – oświetlenie elektryczne we wnętrzach Natężenie oświetlenia\nZakres:\nZakres (0,5 - 10000) lx\nRównomierność oświetlenia (z obliczeń)\nMetoda bezpośredniego pomiaru PB-SP-03 wersja 02 z dnia 04.03.2024 r. Srodowisko pracy – oswietlenie elektryczne we wnetrzach Natezenie oswietlenia\nZakres:\nZakres (0,5 - 10000) lx\nRownomiernosc oswietlenia (z obliczen)\nMetoda bezposredniego pomiaru PB-SP-03 wersja 02 z dnia 04.03.2024 r.","categories":["environment"],"row_index":595,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance","parameters_en":[{"name":"Range","range":"(0,5 - 10000) lx"},{"name":"Illuminance uniformity (calculated)"}],"search_en":"Workplace environment – indoor electric lighting Illuminance Direct measurement method Range Illuminance uniformity (calculated) PB-SP-03 wersja 02 z dnia 04.03.2024 r.","technique_en":"Direct measurement method","test_object_en":"Workplace environment – indoor electric lighting","methodology_zh":"照度","parameters_zh":[{"name":"范围","range":"(0,5 - 10000) lx"},{"name":"照度均匀度（计算值）"}],"search_zh":"工作场所环境 — 室内电气照明 照度 直接测量法 范围 照度均匀度（计算值） PB-SP-03 wersja 02 z dnia 04.03.2024 r.","test_object_zh":"工作场所环境 — 室内电气照明","technique_zh":"直接测量法"},{"_id":"6a8369ecaf14b9c0e7b1de76","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat umiarkowany","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(10 - 30) °C"},{"name":"Wilgotność powietrza"},{"name":"Zakres","range":"(20 - 90) %"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(10 - 40) °C"},{"name":"Prędkość powietrza"},{"name":"Zakres","range":"(0,15 - 1) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (10 - 30) °C\nWilgotność powietrza\nZakres (20 - 90) %\nTemperatura poczernionej kuli\nZakres (10 - 40) °C\nPrędkość powietrza\nZakres (0,15 - 1) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7730:2006","norm_bases":["PN-EN ISO 7730:2006"],"lab_section":"Pracownia Środowiskowa, Dział Pomiarów Jakości Środowiska - Stanowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – mikroklimat umiarkowany Temperatura powietrza\nZakres:\nZakres (10 - 30) °C\nWilgotność powietrza\nZakres (20 - 90) %\nTemperatura poczernionej kuli\nZakres (10 - 40) °C\nPrędkość powietrza\nZakres (0,15 - 1) m/s\nMetoda pomiarowa bezpośrednia PN-EN ISO 7730:2006 Srodowisko pracy – mikroklimat umiarkowany Temperatura powietrza\nZakres:\nZakres (10 - 30) °C\nWilgotnosc powietrza\nZakres (20 - 90) %\nTemperatura poczernionej kuli\nZakres (10 - 40) °C\nPredkosc powietrza\nZakres (0,15 - 1) m/s\nMetoda pomiarowa bezposrednia PN-EN ISO 7730:2006","categories":["environment"],"row_index":596,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(10 - 30) °C"},{"name":"Air humidity"},{"name":"Range","range":"(20 - 90) %"},{"name":"Black globe temperature"},{"name":"Range","range":"(10 - 40) °C"},{"name":"Air velocity"},{"name":"Range","range":"(0,15 - 1) m/s"}],"search_en":"Workplace environment – moderate microclimate Air temperature Direct measurement method Range Air humidity Range Black globe temperature Range Air velocity Range PN-EN ISO 7730:2006","technique_en":"Direct measurement method","test_object_en":"Workplace environment – moderate microclimate","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(10 - 30) °C"},{"name":"空气湿度"},{"name":"范围","range":"(20 - 90) %"},{"name":"黑球温度"},{"name":"范围","range":"(10 - 40) °C"},{"name":"空气流速"},{"name":"范围","range":"(0,15 - 1) m/s"}],"search_zh":"工作场所环境 — 中等微气候 空气温度 直接测量法 范围 空气湿度 范围 黑球温度 范围 空气流速 范围 PN-EN ISO 7730:2006","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 中等微气候"},{"_id":"6a8369ecaf14b9c0e7b1de77","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat umiarkowany","methodology":"Wskaźnik PMV, Wskaźnik PPD (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik PMV, Wskaźnik PPD (z obliczeń)","reference":"PN-EN ISO 7730:2006","norm_bases":["PN-EN ISO 7730:2006"],"lab_section":"Pracownia Środowiskowa, Dział Pomiarów Jakości Środowiska - Stanowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – mikroklimat umiarkowany Wskaźnik PMV, Wskaźnik PPD (z obliczeń) PN-EN ISO 7730:2006 Srodowisko pracy – mikroklimat umiarkowany Wskaznik PMV, Wskaznik PPD (z obliczen) PN-EN ISO 7730:2006","categories":["environment"],"row_index":597,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"PMV index, PPD index (calculated)","search_en":"Workplace environment – moderate microclimate PMV index, PPD index (calculated) PN-EN ISO 7730:2006","test_object_en":"Workplace environment – moderate microclimate","methodology_zh":"PMV 指数、PPD 指数（计算值）","search_zh":"工作场所环境 — 中等微气候 PMV 指数、PPD 指数（计算值） PN-EN ISO 7730:2006","test_object_zh":"工作场所环境 — 中等微气候"},{"_id":"6a8369ecaf14b9c0e7b1de78","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat gorący","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(10 - 70) °C"},{"name":"Temperatura wilgotna naturalna"},{"name":"Zakres","range":"(10 - 60) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(10 - 70) °C"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (10 - 70) °C\nTemperatura wilgotna naturalna\nZakres (10 - 60) °C\nTemperatura poczernionej kuli\nZakres (10 - 70) °C\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7243:2018-01","norm_bases":["PN-EN ISO 7243:2018-01"],"lab_section":"Pracownia Środowiskowa, Dział Pomiarów Jakości Środowiska - Stanowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – mikroklimat gorący Temperatura powietrza\nZakres:\nZakres (10 - 70) °C\nTemperatura wilgotna naturalna\nZakres (10 - 60) °C\nTemperatura poczernionej kuli\nZakres (10 - 70) °C\nMetoda pomiarowa bezpośrednia PN-EN ISO 7243:2018-01 Srodowisko pracy – mikroklimat goracy Temperatura powietrza\nZakres:\nZakres (10 - 70) °C\nTemperatura wilgotna naturalna\nZakres (10 - 60) °C\nTemperatura poczernionej kuli\nZakres (10 - 70) °C\nMetoda pomiarowa bezposrednia PN-EN ISO 7243:2018-01","categories":["environment"],"row_index":598,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(10 - 70) °C"},{"name":"Natural wet bulb temperature"},{"name":"Range","range":"(10 - 60) °C"},{"name":"Black globe temperature"},{"name":"Range","range":"(10 - 70) °C"}],"search_en":"Workplace environment – hot microclimate Air temperature Direct measurement method Range Natural wet bulb temperature Range Black globe temperature Range PN-EN ISO 7243:2018-01","technique_en":"Direct measurement method","test_object_en":"Workplace environment – hot microclimate","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(10 - 70) °C"},{"name":"自然湿球温度"},{"name":"范围","range":"(10 - 60) °C"},{"name":"黑球温度"},{"name":"范围","range":"(10 - 70) °C"}],"search_zh":"工作场所环境 — 高温微气候 空气温度 直接测量法 范围 自然湿球温度 范围 黑球温度 范围 PN-EN ISO 7243:2018-01","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 高温微气候"},{"_id":"6a8369ecaf14b9c0e7b1de79","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat gorący","methodology":"Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń)","reference":"PN-EN ISO 7243:2018-01","norm_bases":["PN-EN ISO 7243:2018-01"],"lab_section":"Pracownia Środowiskowa, Dział Pomiarów Jakości Środowiska - Stanowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – mikroklimat gorący Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń) PN-EN ISO 7243:2018-01 Srodowisko pracy – mikroklimat goracy Wskaznik WBGT, Wskaznik WBGTeff (z obliczen) PN-EN ISO 7243:2018-01","categories":["environment"],"row_index":599,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"WBGT index, WBGTeff index (calculated)","search_en":"Workplace environment – hot microclimate WBGT index, WBGTeff index (calculated) PN-EN ISO 7243:2018-01","test_object_en":"Workplace environment – hot microclimate","methodology_zh":"WBGT 指数、WBGTeff 指数（计算值）","search_zh":"工作场所环境 — 高温微气候 WBGT 指数、WBGTeff 指数（计算值） PN-EN ISO 7243:2018-01","test_object_zh":"工作场所环境 — 高温微气候"},{"_id":"6a8369ecaf14b9c0e7b1de7a","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Środowisko pracy - wydatek energetyczny","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(0 - 40) °C"},{"name":"Przepływ powietrza"},{"name":"Zakres","range":"(10,1 - 60,2) dm3/min"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (0 - 40) °C\nPrzepływ powietrza\nZakres (10,1 - 60,2) dm3/min\nMetoda pomiarowa bezpośrednia","reference":"PB-SP-04 wersja 02 z dnia 05.06.2024 r.","norm_bases":["PB-SP-04 wersja 02 z dnia 05.06.2024 r."],"lab_section":"Pracownia Środowiskowa, Dział Pomiarów Jakości Środowiska - Stanowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - wydatek energetyczny Temperatura powietrza\nZakres:\nZakres (0 - 40) °C\nPrzepływ powietrza\nZakres (10,1 - 60,2) dm3/min\nMetoda pomiarowa bezpośrednia PB-SP-04 wersja 02 z dnia 05.06.2024 r. Srodowisko pracy - wydatek energetyczny Temperatura powietrza\nZakres:\nZakres (0 - 40) °C\nPrzeplyw powietrza\nZakres (10,1 - 60,2) dm3/min\nMetoda pomiarowa bezposrednia PB-SP-04 wersja 02 z dnia 05.06.2024 r.","categories":["environment"],"row_index":600,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(0 - 40) °C"},{"name":"Air flow"},{"name":"Range","range":"(10,1 - 60,2) dm3/min"}],"search_en":"Workplace environment - energy expenditure Air temperature Direct measurement method Range Air flow Range PB-SP-04 wersja 02 z dnia 05.06.2024 r.","technique_en":"Direct measurement method","test_object_en":"Workplace environment - energy expenditure","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(0 - 40) °C"},{"name":"空气流量"},{"name":"范围","range":"(10,1 - 60,2) dm3/min"}],"search_zh":"工作场所环境 — 能量消耗 空气温度 直接测量法 范围 空气流量 范围 PB-SP-04 wersja 02 z dnia 05.06.2024 r.","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 能量消耗"},{"_id":"6a8369ecaf14b9c0e7b1de7b","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Środowisko pracy - wydatek energetyczny","methodology":"Wydatek energetyczny (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wydatek energetyczny (z obliczeń)","reference":"PB-SP-04 wersja 02 z dnia 05.06.2024 r.","norm_bases":["PB-SP-04 wersja 02 z dnia 05.06.2024 r."],"lab_section":"Pracownia Środowiskowa, Dział Pomiarów Jakości Środowiska - Stanowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - wydatek energetyczny Wydatek energetyczny (z obliczeń) PB-SP-04 wersja 02 z dnia 05.06.2024 r. Srodowisko pracy - wydatek energetyczny Wydatek energetyczny (z obliczen) PB-SP-04 wersja 02 z dnia 05.06.2024 r.","categories":["environment"],"row_index":601,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Energy expenditure (calculated)","search_en":"Workplace environment - energy expenditure Energy expenditure (calculated) PB-SP-04 wersja 02 z dnia 05.06.2024 r.","test_object_en":"Workplace environment - energy expenditure","methodology_zh":"能量消耗（计算值）","search_zh":"工作场所环境 — 能量消耗 能量消耗（计算值） PB-SP-04 wersja 02 z dnia 05.06.2024 r.","test_object_zh":"工作场所环境 — 能量消耗"},{"_id":"6a8369ecaf14b9c0e7b1de7c","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Środowisko pracy – drgania przenoszone na organizm człowieka przez kończyny górne","methodology":"Skuteczne ważone","parameters":[{"name":"częstotliwościowo"},{"name":"przyspieszenie drgań"},{"name":"Zakres","range":"(0,2 - 100) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne ważone\nZakres:\nczęstotliwościowo\nprzyspieszenie drgań\nZakres (0,2 - 100) m/s2\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004+A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004+A1:2015-11"],"lab_section":"Pracownia Środowiskowa, Dział Pomiarów Jakości Środowiska - Stanowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania przenoszone na organizm człowieka przez kończyny górne Skuteczne ważone\nZakres:\nczęstotliwościowo\nprzyspieszenie drgań\nZakres (0,2 - 100) m/s2\nMetoda pomiarowa bezpośrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004+A1:2015-11 Srodowisko pracy – drgania przenoszone na organizm czlowieka przez konczyny gorne Skuteczne wazone\nZakres:\nczestotliwosciowo\nprzyspieszenie drgan\nZakres (0,2 - 100) m/s2\nMetoda pomiarowa bezposrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004+A1:2015-11","categories":["environment"],"row_index":602,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"R.m.s. weighted","parameters_en":[{"name":"frequency-weighted"},{"name":"vibration acceleration"},{"name":"Range","range":"(0,2 - 100) m/s2"}],"search_en":"Workplace environment – hand-arm vibration transmitted to the human body R.m.s. weighted Direct measurement method frequency-weighted vibration acceleration Range PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004+A1:2015-11","technique_en":"Direct measurement method","test_object_en":"Workplace environment – hand-arm vibration transmitted to the human body","parameters_zh":[{"name":"频率计权"},{"name":"振动加速度"},{"name":"范围","range":"(0,2 - 100) m/s2"}],"search_zh":"工作环境 － 经上肢传递至人体的振动 有效计权 直接测量法 频率计权 振动加速度 范围 PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004+A1:2015-11","technique_zh":"直接测量法","methodology_zh":"有效计权","test_object_zh":"工作环境 － 经上肢传递至人体的振动"},{"_id":"6a8369ecaf14b9c0e7b1de7d","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Środowisko pracy – drgania przenoszone na organizm człowieka przez kończyny górne","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004+A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004+A1:2015-11"],"lab_section":"Pracownia Środowiskowa, Dział Pomiarów Jakości Środowiska - Stanowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania przenoszone na organizm człowieka przez kończyny górne Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004+A1:2015-11 Srodowisko pracy – drgania przenoszone na organizm czlowieka przez konczyny gorne Ekspozycja dzienna, wyrazona w postaci rownowaznej energetycznie dla 8-godzin dzialania sumy wektorowej skutecznych, skorygowanych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci sumy wektorowej skutecznych, wazonych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz) (z obliczen) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004+A1:2015-11","categories":["environment"],"row_index":603,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated)","search_en":"Workplace environment – hand-arm vibration transmitted to the human body Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004+A1:2015-11","test_object_en":"Workplace environment – hand-arm vibration transmitted to the human body","methodology_zh":"日暴露量，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值矢量和的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值的矢量和表示（计算值）","search_zh":"工作环境 － 经上肢传递至人体的振动 日暴露量，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值矢量和的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值的矢量和表示（计算值） PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004+A1:2015-11","test_object_zh":"工作环境 － 经上肢传递至人体的振动"},{"_id":"6a8369ecaf14b9c0e7b1de7e","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka","methodology":"Skuteczne ważone","parameters":[{"name":"częstotliwościowo"},{"name":"przyspieszenie drgań"},{"name":"Zakres","range":"(0,04 - 120) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne ważone\nZakres:\nczęstotliwościowo\nprzyspieszenie drgań\nZakres (0,04 - 120) m/s2\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":"Pracownia Środowiskowa, Dział Pomiarów Jakości Środowiska - Stanowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka Skuteczne ważone\nZakres:\nczęstotliwościowo\nprzyspieszenie drgań\nZakres (0,04 - 120) m/s2\nMetoda pomiarowa bezpośrednia PN-EN 14253+A1:2011 Srodowisko pracy – drgania o ogolnym dzialaniu na organizm czlowieka Skuteczne wazone\nZakres:\nczestotliwosciowo\nprzyspieszenie drgan\nZakres (0,04 - 120) m/s2\nMetoda pomiarowa bezposrednia PN-EN 14253+A1:2011","categories":["environment"],"row_index":604,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"R.m.s. weighted","parameters_en":[{"name":"frequency-weighted"},{"name":"vibration acceleration"},{"name":"Range","range":"(0,04 - 120) m/s2"}],"search_en":"Workplace environment – whole-body vibration R.m.s. weighted Direct measurement method frequency-weighted vibration acceleration Range PN-EN 14253+A1:2011","technique_en":"Direct measurement method","test_object_en":"Workplace environment – whole-body vibration","parameters_zh":[{"name":"频率计权"},{"name":"振动加速度"},{"name":"范围","range":"(0,04 - 120) m/s2"}],"search_zh":"工作场所环境 — 全身振动 有效计权 直接测量法 频率计权 振动加速度 范围 PN-EN 14253+A1:2011","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 全身振动","methodology_zh":"有效计权"},{"_id":"6a8369ecaf14b9c0e7b1de7f","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń)","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":"Pracownia Środowiskowa, Dział Pomiarów Jakości Środowiska - Stanowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń) PN-EN 14253+A1:2011 Srodowisko pracy – drgania o ogolnym dzialaniu na organizm czlowieka Ekspozycja dzienna, wyrazona w postaci rownowaznego energetycznie dla 8-godzin dzialania skutecznego, skorygowanego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1.4awx, 1.4awy, awz), Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci skutecznego, wazonego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1.4awx, 1.4awy, awz) (z obliczen) PN-EN 14253+A1:2011","categories":["environment"],"row_index":605,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz), Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz) (calculated)","search_en":"Workplace environment – whole-body vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz), Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz) (calculated) PN-EN 14253+A1:2011","test_object_en":"Workplace environment – whole-body vibration","search_zh":"工作场所环境 — 全身振动 日暴露量，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值表示（计算值） PN-EN 14253+A1:2011","test_object_zh":"工作场所环境 — 全身振动","methodology_zh":"日暴露量，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值表示（计算值）"},{"_id":"6a8369ecaf14b9c0e7b1de80","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Środowisko pracy – hałas","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(40 - 136) dB"},{"name":"Szczytowy poziom dźwięku C"},{"name":"Zakres","range":"(40 - 141) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (40 - 136) dB\nSzczytowy poziom dźwięku C\nZakres (40 - 141) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 – pkt. 10 i Strategię 3 – pkt. 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 – pkt. 10 i Strategię 3 – pkt. 11"],"lab_section":"Pracownia Środowiskowa, Dział Pomiarów Jakości Środowiska - Stanowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (40 - 136) dB\nSzczytowy poziom dźwięku C\nZakres (40 - 141) dB\nMetoda pomiarowa bezpośrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 – pkt. 10 i Strategię 3 – pkt. 11 Srodowisko pracy – halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A\nZakres:\nZakres (40 - 136) dB\nSzczytowy poziom dzwieku C\nZakres (40 - 141) dB\nMetoda pomiarowa bezposrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej Strategie 2 – pkt. 10 i Strategie 3 – pkt. 11","categories":["environment"],"row_index":606,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound level Maximum A-weighted sound level","parameters_en":[{"name":"Range","range":"(40 - 136) dB"},{"name":"C-weighted peak sound pressure level"},{"name":"Range","range":"(40 - 141) dB"}],"search_en":"Workplace environment – noise A-weighted equivalent sound level Maximum A-weighted sound level Direct measurement method Range C-weighted peak sound pressure level Range PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 – pkt. 10 i Strategię 3 – pkt. 11","technique_en":"Direct measurement method","test_object_en":"Workplace environment – noise","methodology_zh":"A 计权等效声级 A 计权最大声级","parameters_zh":[{"name":"范围","range":"(40 - 136) dB"},{"name":"C 计权峰值声级"},{"name":"范围","range":"(40 - 141) dB"}],"search_zh":"工作场所环境 — 噪声 A 计权等效声级 A 计权最大声级 直接测量法 范围 C 计权峰值声级 范围 PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 – pkt. 10 i Strategię 3 – pkt. 11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a8369ecaf14b9c0e7b1de81","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Środowisko pracy – hałas","methodology":"Poziom ekspozycji na hałas odniesiony do:","parameters":[{"name":"8-godz. dobowego wymiaru czasu pracy"},{"name":"przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 – pkt. 10 i Strategię 3 – pkt. 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 – pkt. 10 i Strategię 3 – pkt. 11"],"lab_section":"Pracownia Środowiskowa, Dział Pomiarów Jakości Środowiska - Stanowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – hałas Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 – pkt. 10 i Strategię 3 – pkt. 11 Srodowisko pracy – halas Poziom ekspozycji na halas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzecietnego tygodniowego wymiaru czasu pracy (z obliczen) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej Strategie 2 – pkt. 10 i Strategie 3 – pkt. 11","categories":["environment"],"row_index":607,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Noise exposure level referred to:","parameters_en":[{"name":"an 8-hour daily working time"},{"name":"the average weekly working time (calculated)"}],"search_en":"Workplace environment – noise Noise exposure level referred to: an 8-hour daily working time the average weekly working time (calculated) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 – pkt. 10 i Strategię 3 – pkt. 11","test_object_en":"Workplace environment – noise","methodology_zh":"噪声暴露级，参照：","parameters_zh":[{"name":"8 小时日工作时间"},{"name":"平均每周工作时间（计算值）"}],"search_zh":"工作场所环境 — 噪声 噪声暴露级，参照： 8 小时日工作时间 平均每周工作时间（计算值） PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 – pkt. 10 i Strategię 3 – pkt. 11","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a8369ecaf14b9c0e7b1de82","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(25 - 136) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A\nZakres (25 - 136) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) wyłączeniem punktu F","norm_bases":["Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) wyłączeniem punktu F"],"lab_section":"Pracownia Środowiskowa, Dział Pomiarów Jakości Środowiska - Stanowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A\nZakres (25 - 136) dB\nMetoda pomiarowa bezpośrednia Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) wyłączeniem punktu F Srodowisko ogolne – halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A\nZakres (25 - 136) dB\nMetoda pomiarowa bezposrednia Zalacznik nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) wylaczeniem punktu F","categories":["environment"],"row_index":608,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound pressure level","parameters_en":[{"name":"Range","range":"(25 - 136) dB"}],"search_en":"General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level Direct measurement method Range Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) wyłączeniem punktu F","technique_en":"Direct measurement method","test_object_en":"General environment – noise from installations, equipment and industrial plants","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"范围","range":"(25 - 136) dB"}],"search_zh":"一般环境 – 来自设施、设备与工业企业的噪声 A 计权等效声级 直接测量法 范围 Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) wyłączeniem punktu F","technique_zh":"直接测量法","test_object_zh":"一般环境 – 来自设施、设备与工业企业的噪声"},{"_id":"6a8369ecaf14b9c0e7b1de83","lab_id":"69ad52a3de79e566650fb1b5","country":"PL","accr_number":"AB 313","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN","reference":"Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) wyłączeniem punktu F","norm_bases":["Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) wyłączeniem punktu F"],"lab_section":"Pracownia Środowiskowa, Dział Pomiarów Jakości Środowiska - Stanowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) wyłączeniem punktu F Srodowisko ogolne – halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN Zalacznik nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) wylaczeniem punktu F","categories":["environment"],"row_index":609,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Equivalent A-weighted sound level for the reference time T expressed by the indicators LAeqD and LAeqN","search_en":"General environment – noise from installations, equipment and industrial plants Equivalent A-weighted sound level for the reference time T expressed by the indicators LAeqD and LAeqN Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) wyłączeniem punktu F","test_object_en":"General environment – noise from installations, equipment and industrial plants","search_zh":"一般环境 – 来自设施、设备与工业企业的噪声 以 LAeqD 与 LAeqN 指标表示的参考时段 T 内的 A 计权等效声级 Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) wyłączeniem punktu F","test_object_zh":"一般环境 – 来自设施、设备与工业企业的噪声","methodology_zh":"以 LAeqD 与 LAeqN 指标表示的参考时段 T 内的 A 计权等效声级"}],"has_pdf":true}