{"lab":{"_id":"69ad52a3de79e566650fb1a7","accr_number":"AB 298","country":"PL","accr_body":"PCA","address":"im. STANISŁAWA STASZICA w KRAKOWIE, WYDZIAŁ INŻYNIERII LĄDOWEJ I GOSPODARKI ZASOBAMI, KATEDRA GEOMECHANIKI, BUDOWNICTWA I GEOTECHNIKI, LABORATORIUM BADANIA WŁASNOŚCI SKAŁ","categories":["petro"],"city":"Kraków","imported_at":"2026-03-08T10:42:43.265Z","methods_count":39,"name":"AKADEMIA GÓRNICZO-HUTNICZA","parse_status":"parsed","parse_version":3,"pdf_files":["AB_298.pdf"],"scope_summary":"","search_text":"akademia górniczo-hutnicza im. stanisława staszica w krakowie, wydział inżynierii lądowej i gospodarki zasobami, katedra geomechaniki, budownictwa i geotechniki, laboratorium badania własności skał other petro environment water","status":"active","updated_at":"2026-03-08T14:51:08.258Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-13T08:05:18.383Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20298,podmiot.html","fields_of_testing":[{"codes":"J/5","pl":"Badania mechaniczne wyrobów budowlanych, materiałów budowlanych","en":"mechanical tests of building products, building materials"},{"codes":"N/5","pl":"Badania właściwości fizycznych wyrobów budowlanych, materiałów budowlanych","en":"Tests of physical properties of building products, building materials, building items"}],"issue":{"no":"21","date":"01.07.2026"},"parse_date":"2026-08-13T08:05:18.383Z","parse_source":"agent-claude-code","map_coord":[50.061947,19.936856],"map_geo":"nominatim-city","lab_locations":[{"name":"LABORATORIUM BADANIA WŁASNOŚCI SKAŁ","address":"Al. Mickiewicza 30","city":null,"postal":null},{"name":"Laboratorium Badania Własności Skał i Wyrobów Kamieniarskich","address":"Al. Mickiewicza 30, 30-059 Kraków","city":"Kraków","postal":"30-059"},{"name":"Laboratorium Badania Własności Skał i Wyrobów Kamieniarskich; Al. Mickiewicza 30, 30-059 Kraków","address":null,"city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/13/a1ad83ff520ec9a09dda23500a8f465d/AB%20298.pdf","has_en":true,"category_counts":{"other":36,"petro":2,"water":1},"category_scores":{"other":33.23,"petro":0.1,"water":0.03},"has_zh":true,"lab_locations_zh":[{"name":"LABORATORIUM BADANIA WŁASNOŚCI SKAŁ","address":"Al. Mickiewicza 30","city":null,"postal":null},{"name":"Laboratorium Badania Własności Skał i Wyrobów Kamieniarskich","address":"Al. Mickiewicza 30, 30-059 Kraków","city":"Kraków","postal":"30-059"},{"name":"岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków","address":null,"city":null,"postal":null}]},"methods":[{"_id":"6a7d7abe0636ba417e41b8b0","lab_id":"69ad52a3de79e566650fb1a7","country":"PL","accr_number":"AB 298","accr_body":"PCA","test_object":"Skały zwięzłe, Elementy kamienne","methodology":"Gęstość","parameters":[],"technique":"Metoda: w kolbie Le Chateliera","techniques":["Metoda: w kolbie Le Chateliera"],"computed":[],"activity":"Gęstość\nMetoda: w kolbie Le Chateliera","reference":"PN-EN 1936:2010","norm_bases":["PN-EN 1936:2010"],"lab_section":"Laboratorium Badania Własności Skał i Wyrobów Kamieniarskich; Al. Mickiewicza 30, 30-059 Kraków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Skały zwięzłe, Elementy kamienne Gęstość\nMetoda: w kolbie Le Chateliera PN-EN 1936:2010 Skaly zwiezle, Elementy kamienne Gestosc\nMetoda: w kolbie Le Chateliera PN-EN 1936:2010","categories":["other"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków","methodology_en":"Density","search_en":"Consolidated rocks, Stone elements Density Method: in the Le Chatelier flask Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków PN-EN 1936:2010","technique_en":"Method: in the Le Chatelier flask","test_object_en":"Consolidated rocks, Stone elements","methodology_zh":"密度","search_zh":"致密岩石、石材构件 密度 岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków PN-EN 1936:2010","lab_section_zh":"岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków","test_object_zh":"致密岩石、石材构件"},{"_id":"6a7d7abe0636ba417e41b8b1","lab_id":"69ad52a3de79e566650fb1a7","country":"PL","accr_number":"AB 298","accr_body":"PCA","test_object":"Skały zwięzłe, Elementy kamienne","methodology":"Gęstość objętościowa","parameters":[],"technique":"Metoda: bezpośrednia","techniques":["Metoda: bezpośrednia"],"computed":[],"activity":"Gęstość objętościowa\nMetoda: bezpośrednia","reference":"PN-EN 1936:2010","norm_bases":["PN-EN 1936:2010"],"lab_section":"Laboratorium Badania Własności Skał i Wyrobów Kamieniarskich; Al. Mickiewicza 30, 30-059 Kraków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Skały zwięzłe, Elementy kamienne Gęstość objętościowa\nMetoda: bezpośrednia PN-EN 1936:2010 Skaly zwiezle, Elementy kamienne Gestosc objetosciowa\nMetoda: bezposrednia PN-EN 1936:2010","categories":["other"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków","methodology_en":"Bulk density","search_en":"Consolidated rocks, Stone elements Bulk density Method: direct Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków PN-EN 1936:2010","technique_en":"Method: direct","test_object_en":"Consolidated rocks, Stone elements","lab_section_zh":"岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków","methodology_zh":"堆积密度","search_zh":"致密岩石、石材构件 堆积密度 方法：直接法 岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków PN-EN 1936:2010","test_object_zh":"致密岩石、石材构件","technique_zh":"方法：直接法"},{"_id":"6a7d7abe0636ba417e41b8b2","lab_id":"69ad52a3de79e566650fb1a7","country":"PL","accr_number":"AB 298","accr_body":"PCA","test_object":"Skały zwięzłe, Elementy kamienne","methodology":"Nasiąkliwość przy ciśnieniu atmosferycznym","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Nasiąkliwość przy ciśnieniu atmosferycznym","reference":"PN-EN 13755:2008","norm_bases":["PN-EN 13755:2008"],"lab_section":"Laboratorium Badania Własności Skał i Wyrobów Kamieniarskich; Al. Mickiewicza 30, 30-059 Kraków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Skały zwięzłe, Elementy kamienne Nasiąkliwość przy ciśnieniu atmosferycznym PN-EN 13755:2008 Skaly zwiezle, Elementy kamienne Nasiakliwosc przy cisnieniu atmosferycznym PN-EN 13755:2008","categories":["other"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków","methodology_en":"Water absorption at atmospheric pressure","search_en":"Consolidated rocks, Stone elements Water absorption at atmospheric pressure Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków PN-EN 13755:2008","test_object_en":"Consolidated rocks, Stone elements","lab_section_zh":"岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków","search_zh":"致密岩石、石材构件 岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków PN-EN 13755:2008","test_object_zh":"致密岩石、石材构件"},{"_id":"6a7d7abe0636ba417e41b8b3","lab_id":"69ad52a3de79e566650fb1a7","country":"PL","accr_number":"AB 298","accr_body":"PCA","test_object":"Skały zwięzłe, Elementy kamienne","methodology":"Wytrzymałość na ściskanie","parameters":[{"name":"zakres siły","range":"(4 – 3000) kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na ściskanie\nzakres siły (4 – 3000) kN","reference":"PN-EN 1926:2007 | PN-G-04303:1997","norm_bases":["PN-EN 1926:2007","PN-G-04303:1997"],"lab_section":"Laboratorium Badania Własności Skał i Wyrobów Kamieniarskich; Al. Mickiewicza 30, 30-059 Kraków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Skały zwięzłe, Elementy kamienne Wytrzymałość na ściskanie\nzakres siły (4 – 3000) kN PN-EN 1926:2007 | PN-G-04303:1997 Skaly zwiezle, Elementy kamienne Wytrzymalosc na sciskanie\nzakres sily (4 – 3000) kN PN-EN 1926:2007 | PN-G-04303:1997","categories":["other"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków","methodology_en":"Compressive strength","parameters_en":[{"name":"force range","range":"(4 – 3000) kN"}],"search_en":"Consolidated rocks, Stone elements Compressive strength Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków force range PN-EN 1926:2007 | PN-G-04303:1997","test_object_en":"Consolidated rocks, Stone elements","methodology_zh":"抗压强度","search_zh":"致密岩石、石材构件 抗压强度 岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków PN-EN 1926:2007 | PN-G-04303:1997","lab_section_zh":"岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków","test_object_zh":"致密岩石、石材构件"},{"_id":"6a7d7abe0636ba417e41b8b4","lab_id":"69ad52a3de79e566650fb1a7","country":"PL","accr_number":"AB 298","accr_body":"PCA","test_object":"Skały zwięzłe, Elementy kamienne","methodology":"Wytrzymałość na zginanie","parameters":[{"name":"zakres siły","range":"(1 – 25) kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na zginanie\nzakres siły (1 – 25) kN","reference":"PN-EN 12372:2022-08 | PN-G-04305:1997 | PN-EN 13161:2008","norm_bases":["PN-EN 12372:2022-08","PN-G-04305:1997","PN-EN 13161:2008"],"lab_section":"Laboratorium Badania Własności Skał i Wyrobów Kamieniarskich; Al. Mickiewicza 30, 30-059 Kraków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Skały zwięzłe, Elementy kamienne Wytrzymałość na zginanie\nzakres siły (1 – 25) kN PN-EN 12372:2022-08 | PN-G-04305:1997 | PN-EN 13161:2008 Skaly zwiezle, Elementy kamienne Wytrzymalosc na zginanie\nzakres sily (1 – 25) kN PN-EN 12372:2022-08 | PN-G-04305:1997 | PN-EN 13161:2008","categories":["other"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków","methodology_en":"Flexural strength","parameters_en":[{"name":"force range","range":"(1 – 25) kN"}],"search_en":"Consolidated rocks, Stone elements Flexural strength Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków force range PN-EN 12372:2022-08 | PN-G-04305:1997 | PN-EN 13161:2008","test_object_en":"Consolidated rocks, Stone elements","methodology_zh":"抗弯强度","search_zh":"致密岩石、石材构件 抗弯强度 岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków PN-EN 12372:2022-08 | PN-G-04305:1997 | PN-EN 13161:2008","lab_section_zh":"岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków","test_object_zh":"致密岩石、石材构件"},{"_id":"6a7d7abe0636ba417e41b8b5","lab_id":"69ad52a3de79e566650fb1a7","country":"PL","accr_number":"AB 298","accr_body":"PCA","test_object":"Skały zwięzłe, Elementy kamienne","methodology":"Ścieralność na tarczy Boehmego","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ścieralność na tarczy Boehmego","reference":"PN-84/B-04111","norm_bases":["PN-84/B-04111"],"lab_section":"Laboratorium Badania Własności Skał i Wyrobów Kamieniarskich; Al. Mickiewicza 30, 30-059 Kraków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Skały zwięzłe, Elementy kamienne Ścieralność na tarczy Boehmego PN-84/B-04111 Skaly zwiezle, Elementy kamienne Scieralnosc na tarczy Boehmego PN-84/B-04111","categories":["other"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków","methodology_en":"Abrasion resistance on the Böhme disc","search_en":"Consolidated rocks, Stone elements Abrasion resistance on the Böhme disc Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków PN-84/B-04111","test_object_en":"Consolidated rocks, Stone elements","lab_section_zh":"岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków","search_zh":"致密岩石、石材构件 岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków PN-84/B-04111","test_object_zh":"致密岩石、石材构件"},{"_id":"6a7d7abe0636ba417e41b8b6","lab_id":"69ad52a3de79e566650fb1a7","country":"PL","accr_number":"AB 298","accr_body":"PCA","test_object":"Skały zwięzłe, Elementy kamienne","methodology":"Wytrzymałość na rozciąganie","parameters":[{"name":"Zakres siły","range":"(1 – 25) kN"}],"technique":"Metoda: poprzecznego ściskania","techniques":["Metoda: poprzecznego ściskania"],"computed":[],"activity":"Wytrzymałość na rozciąganie\nZakres siły (1 – 25) kN\nMetoda: poprzecznego ściskania","reference":"PN-G-04302:1997","norm_bases":["PN-G-04302:1997"],"lab_section":"Laboratorium Badania Własności Skał i Wyrobów Kamieniarskich; Al. Mickiewicza 30, 30-059 Kraków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Skały zwięzłe, Elementy kamienne Wytrzymałość na rozciąganie\nZakres siły (1 – 25) kN\nMetoda: poprzecznego ściskania PN-G-04302:1997 Skaly zwiezle, Elementy kamienne Wytrzymalosc na rozciaganie\nZakres sily (1 – 25) kN\nMetoda: poprzecznego sciskania PN-G-04302:1997","categories":["other"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków","methodology_en":"Tensile strength","parameters_en":[{"name":"Force range","range":"(1 – 25) kN"}],"search_en":"Consolidated rocks, Stone elements Tensile strength Method: transverse compression Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków Force range PN-G-04302:1997","technique_en":"Method: transverse compression","test_object_en":"Consolidated rocks, Stone elements","parameters_zh":[{"name":"力值范围","range":"(1 – 25) kN"}],"search_zh":"致密岩石、石材构件 抗拉强度 岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków 力值范围 PN-G-04302:1997","lab_section_zh":"岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków","methodology_zh":"抗拉强度","test_object_zh":"致密岩石、石材构件"},{"_id":"6a7d7abe0636ba417e41b8b7","lab_id":"69ad52a3de79e566650fb1a7","country":"PL","accr_number":"AB 298","accr_body":"PCA","test_object":"Skały zwięzłe, Elementy kamienne","methodology":"Obciążenie niszczące przy otworze na kołek","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Obciążenie niszczące przy otworze na kołek","reference":"PN-EN 13364:2002","norm_bases":["PN-EN 13364:2002"],"lab_section":"Laboratorium Badania Własności Skał i Wyrobów Kamieniarskich; Al. Mickiewicza 30, 30-059 Kraków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Skały zwięzłe, Elementy kamienne Obciążenie niszczące przy otworze na kołek PN-EN 13364:2002 Skaly zwiezle, Elementy kamienne Obciazenie niszczace przy otworze na kolek PN-EN 13364:2002","categories":["other"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków","methodology_en":"Failure load at the dowel hole","search_en":"Consolidated rocks, Stone elements Failure load at the dowel hole Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków PN-EN 13364:2002","test_object_en":"Consolidated rocks, Stone elements","lab_section_zh":"岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków","search_zh":"致密岩石、石材构件 岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków PN-EN 13364:2002","test_object_zh":"致密岩石、石材构件"},{"_id":"6a7d7abe0636ba417e41b8b8","lab_id":"69ad52a3de79e566650fb1a7","country":"PL","accr_number":"AB 298","accr_body":"PCA","test_object":"Skały zwięzłe, Elementy kamienne","methodology":"Mrozoodporność","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Mrozoodporność","reference":"PN-EN 12371:2010 | PN-85/B-04102","norm_bases":["PN-EN 12371:2010","PN-85/B-04102"],"lab_section":"Laboratorium Badania Własności Skał i Wyrobów Kamieniarskich; Al. Mickiewicza 30, 30-059 Kraków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Skały zwięzłe, Elementy kamienne Mrozoodporność PN-EN 12371:2010 | PN-85/B-04102 Skaly zwiezle, Elementy kamienne Mrozoodpornosc PN-EN 12371:2010 | PN-85/B-04102","categories":["other"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków","methodology_en":"Frost resistance","search_en":"Consolidated rocks, Stone elements Frost resistance Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków PN-EN 12371:2010 | PN-85/B-04102","test_object_en":"Consolidated rocks, Stone elements","lab_section_zh":"岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków","search_zh":"致密岩石、石材构件 抗冻性 岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków PN-EN 12371:2010 | PN-85/B-04102","methodology_zh":"抗冻性","test_object_zh":"致密岩石、石材构件"},{"_id":"6a7d7abe0636ba417e41b8b9","lab_id":"69ad52a3de79e566650fb1a7","country":"PL","accr_number":"AB 298","accr_body":"PCA","test_object":"Skały zwięzłe, Elementy kamienne","methodology":"Badania petrograficzne","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Badania petrograficzne","reference":"PN-EN 12407:2019-07","norm_bases":["PN-EN 12407:2019-07"],"lab_section":"Laboratorium Badania Własności Skał i Wyrobów Kamieniarskich; Al. Mickiewicza 30, 30-059 Kraków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Skały zwięzłe, Elementy kamienne Badania petrograficzne PN-EN 12407:2019-07 Skaly zwiezle, Elementy kamienne Badania petrograficzne PN-EN 12407:2019-07","categories":["petro"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków","methodology_en":"Petrographic examination","search_en":"Consolidated rocks, Stone elements Petrographic examination Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków PN-EN 12407:2019-07","test_object_en":"Consolidated rocks, Stone elements","lab_section_zh":"岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków","search_zh":"致密岩石、石材构件 岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków PN-EN 12407:2019-07","test_object_zh":"致密岩石、石材构件"},{"_id":"6a7d7abe0636ba417e41b8ba","lab_id":"69ad52a3de79e566650fb1a7","country":"PL","accr_number":"AB 298","accr_body":"PCA","test_object":"Skały zwięzłe, Elementy kamienne","methodology":"Moduł odkształcalności podłużnej","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Moduł odkształcalności podłużnej","reference":"Procedura I/2000 wyd. 1 z dn. 22.02.2000","norm_bases":["Procedura I/2000 wyd. 1 z dn. 22.02.2000"],"lab_section":"Laboratorium Badania Własności Skał i Wyrobów Kamieniarskich; Al. Mickiewicza 30, 30-059 Kraków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Skały zwięzłe, Elementy kamienne Moduł odkształcalności podłużnej Procedura I/2000 wyd. 1 z dn. 22.02.2000 Skaly zwiezle, Elementy kamienne Modul odksztalcalnosci podluznej Procedura I/2000 wyd. 1 z dn. 22.02.2000","categories":["other"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków","methodology_en":"Modulus of longitudinal deformability","search_en":"Consolidated rocks, Stone elements Modulus of longitudinal deformability Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków Procedura I/2000 wyd. 1 z dn. 22.02.2000","test_object_en":"Consolidated rocks, Stone elements","lab_section_zh":"岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków","search_zh":"致密岩石、石材构件 岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków Procedura I/2000 wyd. 1 z dn. 22.02.2000","test_object_zh":"致密岩石、石材构件"},{"_id":"6a7d7abe0636ba417e41b8bb","lab_id":"69ad52a3de79e566650fb1a7","country":"PL","accr_number":"AB 298","accr_body":"PCA","test_object":"Skały zwięzłe, Elementy kamienne","methodology":"Współczynnik odkształcalności poprzecznej","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Współczynnik odkształcalności poprzecznej","reference":"Procedura II/2000 wyd. 1 z dn. 22.02.2000","norm_bases":["Procedura II/2000 wyd. 1 z dn. 22.02.2000"],"lab_section":"Laboratorium Badania Własności Skał i Wyrobów Kamieniarskich; Al. Mickiewicza 30, 30-059 Kraków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Skały zwięzłe, Elementy kamienne Współczynnik odkształcalności poprzecznej Procedura II/2000 wyd. 1 z dn. 22.02.2000 Skaly zwiezle, Elementy kamienne Wspolczynnik odksztalcalnosci poprzecznej Procedura II/2000 wyd. 1 z dn. 22.02.2000","categories":["other"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków","methodology_en":"Coefficient of transverse deformation","search_en":"Consolidated rocks, Stone elements Coefficient of transverse deformation Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków Procedura II/2000 wyd. 1 z dn. 22.02.2000","test_object_en":"Consolidated rocks, Stone elements","lab_section_zh":"岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków","search_zh":"致密岩石、石材构件 岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków Procedura II/2000 wyd. 1 z dn. 22.02.2000","test_object_zh":"致密岩石、石材构件"},{"_id":"6a7d7abe0636ba417e41b8bc","lab_id":"69ad52a3de79e566650fb1a7","country":"PL","accr_number":"AB 298","accr_body":"PCA","test_object":"Skały zwięzłe, Elementy kamienne","methodology":"Gęstość objętościowa i porowatość otwarta metodą hydrostatyczną","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Gęstość objętościowa i porowatość otwarta metodą hydrostatyczną","reference":"Procedura III/2015 wyd. 1 z dn. 22.02.2015","norm_bases":["Procedura III/2015 wyd. 1 z dn. 22.02.2015"],"lab_section":"Laboratorium Badania Własności Skał i Wyrobów Kamieniarskich; Al. Mickiewicza 30, 30-059 Kraków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Skały zwięzłe, Elementy kamienne Gęstość objętościowa i porowatość otwarta metodą hydrostatyczną Procedura III/2015 wyd. 1 z dn. 22.02.2015 Skaly zwiezle, Elementy kamienne Gestosc objetosciowa i porowatosc otwarta metoda hydrostatyczna Procedura III/2015 wyd. 1 z dn. 22.02.2015","categories":["other"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków","methodology_en":"Bulk density and open porosity by the hydrostatic method","search_en":"Consolidated rocks, Stone elements Bulk density and open porosity by the hydrostatic method Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków Procedura III/2015 wyd. 1 z dn. 22.02.2015","test_object_en":"Consolidated rocks, Stone elements","lab_section_zh":"岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków","search_zh":"致密岩石、石材构件 岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków Procedura III/2015 wyd. 1 z dn. 22.02.2015","test_object_zh":"致密岩石、石材构件"},{"_id":"6a7d7abe0636ba417e41b8bd","lab_id":"69ad52a3de79e566650fb1a7","country":"PL","accr_number":"AB 298","accr_body":"PCA","test_object":"Skały zwięzłe, Elementy kamienne","methodology":"Nasiąkliwość kapilarna","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Nasiąkliwość kapilarna","reference":"PN-EN 1925:2001","norm_bases":["PN-EN 1925:2001"],"lab_section":"Laboratorium Badania Własności Skał i Wyrobów Kamieniarskich; Al. Mickiewicza 30, 30-059 Kraków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Skały zwięzłe, Elementy kamienne Nasiąkliwość kapilarna PN-EN 1925:2001 Skaly zwiezle, Elementy kamienne Nasiakliwosc kapilarna PN-EN 1925:2001","categories":["other"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków","methodology_en":"Capillary water absorption","search_en":"Consolidated rocks, Stone elements Capillary water absorption Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków PN-EN 1925:2001","test_object_en":"Consolidated rocks, Stone elements","lab_section_zh":"岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków","search_zh":"致密岩石、石材构件 岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków PN-EN 1925:2001","test_object_zh":"致密岩石、石材构件"},{"_id":"6a7d7abe0636ba417e41b8be","lab_id":"69ad52a3de79e566650fb1a7","country":"PL","accr_number":"AB 298","accr_body":"PCA","test_object":"Kruszywa","methodology":"Skład ziarnowy","parameters":[{"name":"Zakres","range":"(0 – 63) mm"}],"technique":"Metoda przesiewania","techniques":["Metoda przesiewania"],"computed":[],"activity":"Skład ziarnowy\nZakres (0 – 63) mm\nMetoda przesiewania","reference":"PN-EN 933-1:2012","norm_bases":["PN-EN 933-1:2012"],"lab_section":"Laboratorium Badania Własności Skał i Wyrobów Kamieniarskich; Al. Mickiewicza 30, 30-059 Kraków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Skład ziarnowy\nZakres (0 – 63) mm\nMetoda przesiewania PN-EN 933-1:2012 Kruszywa Sklad ziarnowy\nZakres (0 – 63) mm\nMetoda przesiewania PN-EN 933-1:2012","categories":["other"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków","methodology_en":"Particle size distribution","parameters_en":[{"name":"Range","range":"(0 – 63) mm"}],"search_en":"Aggregates Particle size distribution Sieving method Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków Range PN-EN 933-1:2012","technique_en":"Sieving method","test_object_en":"Aggregates","parameters_zh":[{"name":"范围","range":"(0 – 63) mm"}],"search_zh":"骨料 粒度分布 筛分法 岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków 范围 PN-EN 933-1:2012","test_object_zh":"骨料","methodology_zh":"粒度分布","lab_section_zh":"岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków","technique_zh":"筛分法"},{"_id":"6a7d7abe0636ba417e41b8bf","lab_id":"69ad52a3de79e566650fb1a7","country":"PL","accr_number":"AB 298","accr_body":"PCA","test_object":"Kruszywa","methodology":"Wskaźnik płaskości","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik płaskości","reference":"PN-EN 933-3:2012","norm_bases":["PN-EN 933-3:2012"],"lab_section":"Laboratorium Badania Własności Skał i Wyrobów Kamieniarskich; Al. Mickiewicza 30, 30-059 Kraków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Wskaźnik płaskości PN-EN 933-3:2012 Kruszywa Wskaznik plaskosci PN-EN 933-3:2012","categories":["other"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków","methodology_en":"Flakiness index","search_en":"Aggregates Flakiness index Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków PN-EN 933-3:2012","test_object_en":"Aggregates","search_zh":"骨料 片状指数 岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków PN-EN 933-3:2012","test_object_zh":"骨料","lab_section_zh":"岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków","methodology_zh":"片状指数"},{"_id":"6a7d7abe0636ba417e41b8c0","lab_id":"69ad52a3de79e566650fb1a7","country":"PL","accr_number":"AB 298","accr_body":"PCA","test_object":"Kruszywa","methodology":"Wskaźnik kształtu","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik kształtu","reference":"PN-EN 933-4:2008","norm_bases":["PN-EN 933-4:2008"],"lab_section":"Laboratorium Badania Własności Skał i Wyrobów Kamieniarskich; Al. Mickiewicza 30, 30-059 Kraków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Wskaźnik kształtu PN-EN 933-4:2008 Kruszywa Wskaznik ksztaltu PN-EN 933-4:2008","categories":["other"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków","methodology_en":"Shape index","search_en":"Aggregates Shape index Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków PN-EN 933-4:2008","test_object_en":"Aggregates","search_zh":"骨料 形状指数 岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków PN-EN 933-4:2008","test_object_zh":"骨料","lab_section_zh":"岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków","methodology_zh":"形状指数"},{"_id":"6a7d7abe0636ba417e41b8c1","lab_id":"69ad52a3de79e566650fb1a7","country":"PL","accr_number":"AB 298","accr_body":"PCA","test_object":"Kruszywa","methodology":"Kształt ziarn","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Kształt ziarn","reference":"PN-EN 13383-2:2019-07","norm_bases":["PN-EN 13383-2:2019-07"],"lab_section":"Laboratorium Badania Własności Skał i Wyrobów Kamieniarskich; Al. Mickiewicza 30, 30-059 Kraków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Kształt ziarn PN-EN 13383-2:2019-07 Kruszywa Ksztalt ziarn PN-EN 13383-2:2019-07","categories":["other"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków","methodology_en":"Particle shape","search_en":"Aggregates Particle shape Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków PN-EN 13383-2:2019-07","test_object_en":"Aggregates","search_zh":"骨料 岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków PN-EN 13383-2:2019-07","test_object_zh":"骨料","lab_section_zh":"岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków"},{"_id":"6a7d7abe0636ba417e41b8c2","lab_id":"69ad52a3de79e566650fb1a7","country":"PL","accr_number":"AB 298","accr_body":"PCA","test_object":"Kruszywa","methodology":"Uproszczony opis petrograficzny","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Uproszczony opis petrograficzny","reference":"PN-EN 932-3:2022-12","norm_bases":["PN-EN 932-3:2022-12"],"lab_section":"Laboratorium Badania Własności Skał i Wyrobów Kamieniarskich; Al. Mickiewicza 30, 30-059 Kraków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Uproszczony opis petrograficzny PN-EN 932-3:2022-12 Kruszywa Uproszczony opis petrograficzny PN-EN 932-3:2022-12","categories":["petro"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków","methodology_en":"Simplified petrographic description","search_en":"Aggregates Simplified petrographic description Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków PN-EN 932-3:2022-12","test_object_en":"Aggregates","search_zh":"骨料 简化岩相描述 岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków PN-EN 932-3:2022-12","test_object_zh":"骨料","lab_section_zh":"岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków","methodology_zh":"简化岩相描述"},{"_id":"6a7d7abe0636ba417e41b8c3","lab_id":"69ad52a3de79e566650fb1a7","country":"PL","accr_number":"AB 298","accr_body":"PCA","test_object":"Kruszywa","methodology":"Wskaźnik piaskowy","parameters":[{"name":"Zakres","range":"(0-2) mm"}],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik piaskowy\nZakres (0-2) mm","reference":"PN-EN 933-8+A1:2015-07","norm_bases":["PN-EN 933-8+A1:2015-07"],"lab_section":"Laboratorium Badania Własności Skał i Wyrobów Kamieniarskich; Al. Mickiewicza 30, 30-059 Kraków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Wskaźnik piaskowy\nZakres (0-2) mm PN-EN 933-8+A1:2015-07 Kruszywa Wskaznik piaskowy\nZakres (0-2) mm PN-EN 933-8+A1:2015-07","categories":["other"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków","methodology_en":"Sand equivalent value","parameters_en":[{"name":"Range","range":"(0-2) mm"}],"search_en":"Aggregates Sand equivalent value Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków Range PN-EN 933-8+A1:2015-07","test_object_en":"Aggregates","parameters_zh":[{"name":"范围","range":"(0-2) mm"}],"search_zh":"骨料 砂当量 岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków 范围 PN-EN 933-8+A1:2015-07","test_object_zh":"骨料","lab_section_zh":"岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków","methodology_zh":"砂当量"},{"_id":"6a7d7abe0636ba417e41b8c4","lab_id":"69ad52a3de79e566650fb1a7","country":"PL","accr_number":"AB 298","accr_body":"PCA","test_object":"Kruszywa","methodology":"Gęstość ziarn i nasiąkliwość","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Gęstość ziarn i nasiąkliwość","reference":"PN-EN 1097-6:2022-07","norm_bases":["PN-EN 1097-6:2022-07"],"lab_section":"Laboratorium Badania Własności Skał i Wyrobów Kamieniarskich; Al. Mickiewicza 30, 30-059 Kraków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Gęstość ziarn i nasiąkliwość PN-EN 1097-6:2022-07 Kruszywa Gestosc ziarn i nasiakliwosc PN-EN 1097-6:2022-07","categories":["other"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków","methodology_en":"Particle density and water absorption","search_en":"Aggregates Particle density and water absorption Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków PN-EN 1097-6:2022-07","test_object_en":"Aggregates","search_zh":"骨料 颗粒密度与吸水率 岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków PN-EN 1097-6:2022-07","test_object_zh":"骨料","lab_section_zh":"岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków","methodology_zh":"颗粒密度与吸水率"},{"_id":"6a7d7abe0636ba417e41b8c5","lab_id":"69ad52a3de79e566650fb1a7","country":"PL","accr_number":"AB 298","accr_body":"PCA","test_object":"Kruszywa","methodology":"Gęstość ziarn i nasiąkliwość","parameters":[],"technique":"Metoda: kosza","techniques":["Metoda: kosza"],"computed":[],"activity":"Gęstość ziarn i nasiąkliwość\nMetoda: kosza","reference":"PN-EN 13383-2:2019-07","norm_bases":["PN-EN 13383-2:2019-07"],"lab_section":"Laboratorium Badania Własności Skał i Wyrobów Kamieniarskich; Al. Mickiewicza 30, 30-059 Kraków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Gęstość ziarn i nasiąkliwość\nMetoda: kosza PN-EN 13383-2:2019-07 Kruszywa Gestosc ziarn i nasiakliwosc\nMetoda: kosza PN-EN 13383-2:2019-07","categories":["other"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków","methodology_en":"Particle density and water absorption","search_en":"Aggregates Particle density and water absorption Method: basket Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków PN-EN 13383-2:2019-07","technique_en":"Method: basket","test_object_en":"Aggregates","search_zh":"骨料 颗粒密度与吸水率 岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków PN-EN 13383-2:2019-07","test_object_zh":"骨料","lab_section_zh":"岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków","methodology_zh":"颗粒密度与吸水率"},{"_id":"6a7d7abe0636ba417e41b8c6","lab_id":"69ad52a3de79e566650fb1a7","country":"PL","accr_number":"AB 298","accr_body":"PCA","test_object":"Kruszywa","methodology":"Gęstość nasypowa i jamistość","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Gęstość nasypowa i jamistość","reference":"PN-EN 1097-3:2000 z wyłączeniem Załącznika A","norm_bases":["PN-EN 1097-3:2000 z wyłączeniem Załącznika A"],"lab_section":"Laboratorium Badania Własności Skał i Wyrobów Kamieniarskich; Al. Mickiewicza 30, 30-059 Kraków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Gęstość nasypowa i jamistość PN-EN 1097-3:2000 z wyłączeniem Załącznika A Kruszywa Gestosc nasypowa i jamistosc PN-EN 1097-3:2000 z wylaczeniem Zalacznika A","categories":["other"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków","methodology_en":"Bulk density and voids","search_en":"Aggregates Bulk density and voids Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków PN-EN 1097-3:2000 z wyłączeniem Załącznika A","test_object_en":"Aggregates","search_zh":"骨料 堆积密度与空隙率 岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków PN-EN 1097-3:2000 z wyłączeniem Załącznika A","test_object_zh":"骨料","lab_section_zh":"岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków","methodology_zh":"堆积密度与空隙率"},{"_id":"6a7d7abe0636ba417e41b8c7","lab_id":"69ad52a3de79e566650fb1a7","country":"PL","accr_number":"AB 298","accr_body":"PCA","test_object":"Kruszywa","methodology":"Mrozoodporność","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Mrozoodporność","reference":"PN-EN 1367-1:2007","norm_bases":["PN-EN 1367-1:2007"],"lab_section":"Laboratorium Badania Własności Skał i Wyrobów Kamieniarskich; Al. Mickiewicza 30, 30-059 Kraków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Mrozoodporność PN-EN 1367-1:2007 Kruszywa Mrozoodpornosc PN-EN 1367-1:2007","categories":["other"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków","methodology_en":"Frost resistance","search_en":"Aggregates Frost resistance Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków PN-EN 1367-1:2007","test_object_en":"Aggregates","search_zh":"骨料 抗冻性 岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków PN-EN 1367-1:2007","test_object_zh":"骨料","lab_section_zh":"岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków","methodology_zh":"抗冻性"},{"_id":"6a7d7abe0636ba417e41b8c8","lab_id":"69ad52a3de79e566650fb1a7","country":"PL","accr_number":"AB 298","accr_body":"PCA","test_object":"Kruszywa","methodology":"Mrozoodporność w obecności soli","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Mrozoodporność w obecności soli","reference":"PN-EN 1367-6:2008","norm_bases":["PN-EN 1367-6:2008"],"lab_section":"Laboratorium Badania Własności Skał i Wyrobów Kamieniarskich; Al. Mickiewicza 30, 30-059 Kraków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Mrozoodporność w obecności soli PN-EN 1367-6:2008 Kruszywa Mrozoodpornosc w obecnosci soli PN-EN 1367-6:2008","categories":["other"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków","methodology_en":"Frost resistance in the presence of salt","search_en":"Aggregates Frost resistance in the presence of salt Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków PN-EN 1367-6:2008","test_object_en":"Aggregates","search_zh":"骨料 盐冻抗冻性 岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków PN-EN 1367-6:2008","test_object_zh":"骨料","lab_section_zh":"岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków","methodology_zh":"盐冻抗冻性"},{"_id":"6a7d7abe0636ba417e41b8c9","lab_id":"69ad52a3de79e566650fb1a7","country":"PL","accr_number":"AB 298","accr_body":"PCA","test_object":"Kruszywa","methodology":"Mrozoodporność","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Mrozoodporność","reference":"PN-EN 13383-2:2019-07","norm_bases":["PN-EN 13383-2:2019-07"],"lab_section":"Laboratorium Badania Własności Skał i Wyrobów Kamieniarskich; Al. Mickiewicza 30, 30-059 Kraków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Mrozoodporność PN-EN 13383-2:2019-07 Kruszywa Mrozoodpornosc PN-EN 13383-2:2019-07","categories":["other"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków","methodology_en":"Frost resistance","search_en":"Aggregates Frost resistance Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków PN-EN 13383-2:2019-07","test_object_en":"Aggregates","search_zh":"骨料 抗冻性 岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków PN-EN 13383-2:2019-07","test_object_zh":"骨料","lab_section_zh":"岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków","methodology_zh":"抗冻性"},{"_id":"6a7d7abe0636ba417e41b8ca","lab_id":"69ad52a3de79e566650fb1a7","country":"PL","accr_number":"AB 298","accr_body":"PCA","test_object":"Kruszywa","methodology":"Odporność na ścieranie","parameters":[],"technique":"Metoda: mikro-Deval","techniques":["Metoda: mikro-Deval"],"computed":[],"activity":"Odporność na ścieranie\nMetoda: mikro-Deval","reference":"PN-EN 1097-1:2024-05","norm_bases":["PN-EN 1097-1:2024-05"],"lab_section":"Laboratorium Badania Własności Skał i Wyrobów Kamieniarskich; Al. Mickiewicza 30, 30-059 Kraków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Odporność na ścieranie\nMetoda: mikro-Deval PN-EN 1097-1:2024-05 Kruszywa Odpornosc na scieranie\nMetoda: mikro-Deval PN-EN 1097-1:2024-05","categories":["other"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków","methodology_en":"Abrasion resistance","search_en":"Aggregates Abrasion resistance Method: micro-Deval Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków PN-EN 1097-1:2024-05","technique_en":"Method: micro-Deval","test_object_en":"Aggregates","search_zh":"骨料 耐磨性 岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków PN-EN 1097-1:2024-05","test_object_zh":"骨料","lab_section_zh":"岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków","methodology_zh":"耐磨性"},{"_id":"6a7d7abe0636ba417e41b8cb","lab_id":"69ad52a3de79e566650fb1a7","country":"PL","accr_number":"AB 298","accr_body":"PCA","test_object":"Kruszywa","methodology":"Odporność na rozdrabnianie","parameters":[],"technique":"Metoda: Los Angeles","techniques":["Metoda: Los Angeles"],"computed":[],"activity":"Odporność na rozdrabnianie\nMetoda: Los Angeles","reference":"PN-EN 1097-2:2020-09","norm_bases":["PN-EN 1097-2:2020-09"],"lab_section":"Laboratorium Badania Własności Skał i Wyrobów Kamieniarskich; Al. Mickiewicza 30, 30-059 Kraków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Odporność na rozdrabnianie\nMetoda: Los Angeles PN-EN 1097-2:2020-09 Kruszywa Odpornosc na rozdrabnianie\nMetoda: Los Angeles PN-EN 1097-2:2020-09","categories":["other"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków","methodology_en":"Resistance to fragmentation","search_en":"Aggregates Resistance to fragmentation Method: Los Angeles Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków PN-EN 1097-2:2020-09","technique_en":"Method: Los Angeles","test_object_en":"Aggregates","search_zh":"骨料 抗破碎性 方法：洛杉矶法 岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków PN-EN 1097-2:2020-09","test_object_zh":"骨料","lab_section_zh":"岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków","methodology_zh":"抗破碎性","technique_zh":"方法：洛杉矶法"},{"_id":"6a7d7abe0636ba417e41b8cc","lab_id":"69ad52a3de79e566650fb1a7","country":"PL","accr_number":"AB 298","accr_body":"PCA","test_object":"Kruszywa","methodology":"Wytrzymałość na miażdżenie","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na miażdżenie","reference":"PN-78/B-06714/40","norm_bases":["PN-78/B-06714/40"],"lab_section":"Laboratorium Badania Własności Skał i Wyrobów Kamieniarskich; Al. Mickiewicza 30, 30-059 Kraków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Wytrzymałość na miażdżenie PN-78/B-06714/40 Kruszywa Wytrzymalosc na miazdzenie PN-78/B-06714/40","categories":["other"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków","methodology_en":"Crushing strength","search_en":"Aggregates Crushing strength Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków PN-78/B-06714/40","test_object_en":"Aggregates","search_zh":"骨料 岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków PN-78/B-06714/40","test_object_zh":"骨料","lab_section_zh":"岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków"},{"_id":"6a7d7abe0636ba417e41b8cd","lab_id":"69ad52a3de79e566650fb1a7","country":"PL","accr_number":"AB 298","accr_body":"PCA","test_object":"Kruszywa","methodology":"Zawartość zanieczyszczeń obcych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość zanieczyszczeń obcych","reference":"PN-76/B-06714/12","norm_bases":["PN-76/B-06714/12"],"lab_section":"Laboratorium Badania Własności Skał i Wyrobów Kamieniarskich; Al. Mickiewicza 30, 30-059 Kraków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Zawartość zanieczyszczeń obcych PN-76/B-06714/12 Kruszywa Zawartosc zanieczyszczen obcych PN-76/B-06714/12","categories":["other"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków","methodology_en":"Foreign matter content","search_en":"Aggregates Foreign matter content Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków PN-76/B-06714/12","test_object_en":"Aggregates","search_zh":"骨料 岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków PN-76/B-06714/12","test_object_zh":"骨料","lab_section_zh":"岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków"},{"_id":"6a7d7abe0636ba417e41b8ce","lab_id":"69ad52a3de79e566650fb1a7","country":"PL","accr_number":"AB 298","accr_body":"PCA","test_object":"Kruszywa","methodology":"Długość ziarna","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Długość ziarna","reference":"PN-EN 13450:2004 | PN-EN 13450:2004/AC:2004","norm_bases":["PN-EN 13450:2004","PN-EN 13450:2004/AC:2004"],"lab_section":"Laboratorium Badania Własności Skał i Wyrobów Kamieniarskich; Al. Mickiewicza 30, 30-059 Kraków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Długość ziarna PN-EN 13450:2004 | PN-EN 13450:2004/AC:2004 Kruszywa Dlugosc ziarna PN-EN 13450:2004 | PN-EN 13450:2004/AC:2004","categories":["other"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków","methodology_en":"Grain length","search_en":"Aggregates Grain length Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków PN-EN 13450:2004 | PN-EN 13450:2004/AC:2004","test_object_en":"Aggregates","search_zh":"骨料 颗粒长度 岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków PN-EN 13450:2004 | PN-EN 13450:2004/AC:2004","test_object_zh":"骨料","lab_section_zh":"岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków","methodology_zh":"颗粒长度"},{"_id":"6a7d7abe0636ba417e41b8cf","lab_id":"69ad52a3de79e566650fb1a7","country":"PL","accr_number":"AB 298","accr_body":"PCA","test_object":"Kruszywa","methodology":"Zawartość ziarn przekruszonych w kruszywie grubym i o ciągłym uziarnieniu","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość ziarn przekruszonych w kruszywie grubym i o ciągłym uziarnieniu","reference":"PN-EN 933-5:2023-05","norm_bases":["PN-EN 933-5:2023-05"],"lab_section":"Laboratorium Badania Własności Skał i Wyrobów Kamieniarskich; Al. Mickiewicza 30, 30-059 Kraków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Zawartość ziarn przekruszonych w kruszywie grubym i o ciągłym uziarnieniu PN-EN 933-5:2023-05 Kruszywa Zawartosc ziarn przekruszonych w kruszywie grubym i o ciaglym uziarnieniu PN-EN 933-5:2023-05","categories":["other"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków","methodology_en":"Content of crushed particles in coarse and all-in aggregate","search_en":"Aggregates Content of crushed particles in coarse and all-in aggregate Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków PN-EN 933-5:2023-05","test_object_en":"Aggregates","search_zh":"骨料 岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków PN-EN 933-5:2023-05","test_object_zh":"骨料","lab_section_zh":"岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków"},{"_id":"6a7d7abe0636ba417e41b8d0","lab_id":"69ad52a3de79e566650fb1a7","country":"PL","accr_number":"AB 298","accr_body":"PCA","test_object":"Kruszywa","methodology":"Zawartość wody","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość wody","reference":"PN-EN 1097-5:2008","norm_bases":["PN-EN 1097-5:2008"],"lab_section":"Laboratorium Badania Własności Skał i Wyrobów Kamieniarskich; Al. Mickiewicza 30, 30-059 Kraków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Zawartość wody PN-EN 1097-5:2008 Kruszywa Zawartosc wody PN-EN 1097-5:2008","categories":["water"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków","methodology_en":"Water content","search_en":"Aggregates Water content Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków PN-EN 1097-5:2008","test_object_en":"Aggregates","methodology_zh":"水分含量","search_zh":"骨料 水分含量 岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków PN-EN 1097-5:2008","test_object_zh":"骨料","lab_section_zh":"岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków"},{"_id":"6a7d7abe0636ba417e41b8d1","lab_id":"69ad52a3de79e566650fb1a7","country":"PL","accr_number":"AB 298","accr_body":"PCA","test_object":"Kruszywa","methodology":"Reaktywność alkaliczna","parameters":[],"technique":"Metoda: szybka","techniques":["Metoda: szybka"],"computed":[],"activity":"Reaktywność alkaliczna\nMetoda: szybka","reference":"PN-92/B-06714/46","norm_bases":["PN-92/B-06714/46"],"lab_section":"Laboratorium Badania Własności Skał i Wyrobów Kamieniarskich; Al. Mickiewicza 30, 30-059 Kraków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Reaktywność alkaliczna\nMetoda: szybka PN-92/B-06714/46 Kruszywa Reaktywnosc alkaliczna\nMetoda: szybka PN-92/B-06714/46","categories":["other"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków","methodology_en":"Alkali reactivity","search_en":"Aggregates Alkali reactivity Method: rapid Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków PN-92/B-06714/46","technique_en":"Method: rapid","test_object_en":"Aggregates","search_zh":"骨料 碱活性 岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków PN-92/B-06714/46","test_object_zh":"骨料","lab_section_zh":"岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków","methodology_zh":"碱活性"},{"_id":"6a7d7abe0636ba417e41b8d2","lab_id":"69ad52a3de79e566650fb1a7","country":"PL","accr_number":"AB 298","accr_body":"PCA","test_object":"Kruszywa","methodology":"Obecność humusu","parameters":[],"technique":"Metoda: wizualna","techniques":["Metoda: wizualna"],"computed":[],"activity":"Obecność humusu\nMetoda: wizualna","reference":"PN-EN 1744-1+A1:2013-05","norm_bases":["PN-EN 1744-1+A1:2013-05"],"lab_section":"Laboratorium Badania Własności Skał i Wyrobów Kamieniarskich; Al. Mickiewicza 30, 30-059 Kraków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Obecność humusu\nMetoda: wizualna PN-EN 1744-1+A1:2013-05 Kruszywa Obecnosc humusu\nMetoda: wizualna PN-EN 1744-1+A1:2013-05","categories":["other"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków","methodology_en":"Presence of humus","search_en":"Aggregates Presence of humus Method: visual Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków PN-EN 1744-1+A1:2013-05","technique_en":"Method: visual","test_object_en":"Aggregates","search_zh":"骨料 腐殖质的检出 方法：目视法 岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków PN-EN 1744-1+A1:2013-05","test_object_zh":"骨料","lab_section_zh":"岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków","methodology_zh":"腐殖质的检出","technique_zh":"方法：目视法"},{"_id":"6a7d7abe0636ba417e41b8d3","lab_id":"69ad52a3de79e566650fb1a7","country":"PL","accr_number":"AB 298","accr_body":"PCA","test_object":"Grunty/kruszywa","methodology":"Wilgotność optymalna, Maksymalna gęstość objętościowa szkieletu gruntowego","parameters":[],"technique":"Metoda Proctora","techniques":["Metoda Proctora"],"computed":[],"activity":"Wilgotność optymalna, Maksymalna gęstość objętościowa szkieletu gruntowego\nMetoda Proctora","reference":"PN-B-04481:1988","norm_bases":["PN-B-04481:1988"],"lab_section":"Laboratorium Badania Własności Skał i Wyrobów Kamieniarskich; Al. Mickiewicza 30, 30-059 Kraków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty/kruszywa Wilgotność optymalna, Maksymalna gęstość objętościowa szkieletu gruntowego\nMetoda Proctora PN-B-04481:1988 Grunty/kruszywa Wilgotnosc optymalna, Maksymalna gestosc objetosciowa szkieletu gruntowego\nMetoda Proctora PN-B-04481:1988","categories":["other"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków","methodology_en":"Optimum moisture content, Maximum dry density of the soil skeleton","search_en":"Soils/aggregates Optimum moisture content, Maximum dry density of the soil skeleton Proctor method Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków PN-B-04481:1988","technique_en":"Proctor method","test_object_en":"Soils/aggregates","lab_section_zh":"岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków","search_zh":"最佳含水率、土骨架最大干密度 普氏击实法 岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków PN-B-04481:1988","technique_zh":"普氏击实法","methodology_zh":"最佳含水率、土骨架最大干密度"},{"_id":"6a7d7abe0636ba417e41b8d4","lab_id":"69ad52a3de79e566650fb1a7","country":"PL","accr_number":"AB 298","accr_body":"PCA","test_object":"Grunty/kruszywa","methodology":"Wytrzymałość na ścinanie, Spójność i kąt tarcia wewnętrznego, W aparacie bezpośredniego ścinania","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na ścinanie, Spójność i kąt tarcia wewnętrznego, W aparacie bezpośredniego ścinania","reference":"PN-B-04481:1988 | PN-EN ISO 17892-10:2019-01","norm_bases":["PN-B-04481:1988","PN-EN ISO 17892-10:2019-01"],"lab_section":"Laboratorium Badania Własności Skał i Wyrobów Kamieniarskich; Al. Mickiewicza 30, 30-059 Kraków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty/kruszywa Wytrzymałość na ścinanie, Spójność i kąt tarcia wewnętrznego, W aparacie bezpośredniego ścinania PN-B-04481:1988 | PN-EN ISO 17892-10:2019-01 Grunty/kruszywa Wytrzymalosc na scinanie, Spojnosc i kat tarcia wewnetrznego, W aparacie bezposredniego scinania PN-B-04481:1988 | PN-EN ISO 17892-10:2019-01","categories":["other"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków","methodology_en":"Shear strength, Cohesion and angle of internal friction, In a direct shear apparatus","search_en":"Soils/aggregates Shear strength, Cohesion and angle of internal friction, In a direct shear apparatus Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków PN-B-04481:1988 | PN-EN ISO 17892-10:2019-01","test_object_en":"Soils/aggregates","lab_section_zh":"岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków","search_zh":"岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków PN-B-04481:1988 | PN-EN ISO 17892-10:2019-01"},{"_id":"6a7d7abe0636ba417e41b8d5","lab_id":"69ad52a3de79e566650fb1a7","country":"PL","accr_number":"AB 298","accr_body":"PCA","test_object":"Mieszanki niezwiązane i związane spoiwem hydraulicznym","methodology":"Kalifornijski wskaźnik nośności CBR","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Kalifornijski wskaźnik nośności CBR","reference":"PN-EN 13286-47:2022-04","norm_bases":["PN-EN 13286-47:2022-04"],"lab_section":"Laboratorium Badania Własności Skał i Wyrobów Kamieniarskich; Al. Mickiewicza 30, 30-059 Kraków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszanki niezwiązane i związane spoiwem hydraulicznym Kalifornijski wskaźnik nośności CBR PN-EN 13286-47:2022-04 Mieszanki niezwiazane i zwiazane spoiwem hydraulicznym Kalifornijski wskaznik nosnosci CBR PN-EN 13286-47:2022-04","categories":["other"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków","methodology_en":"California Bearing Ratio CBR","search_en":"Unbound and hydraulically bound mixtures California Bearing Ratio CBR Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków PN-EN 13286-47:2022-04","test_object_en":"Unbound and hydraulically bound mixtures","lab_section_zh":"岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków","search_zh":"未结合与水硬性胶结料结合的混合料 加州承载比 CBR 岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków PN-EN 13286-47:2022-04","test_object_zh":"未结合与水硬性胶结料结合的混合料","methodology_zh":"加州承载比 CBR"},{"_id":"6a7d7abe0636ba417e41b8d6","lab_id":"69ad52a3de79e566650fb1a7","country":"PL","accr_number":"AB 298","accr_body":"PCA","test_object":"Mieszanki niezwiązane i związane spoiwem hydraulicznym","methodology":"Wskaźnik nośności Wnoś (CBR)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik nośności Wnoś (CBR)","reference":"PN-S-06102:1997 załącznik A","norm_bases":["PN-S-06102:1997 załącznik A"],"lab_section":"Laboratorium Badania Własności Skał i Wyrobów Kamieniarskich; Al. Mickiewicza 30, 30-059 Kraków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszanki niezwiązane i związane spoiwem hydraulicznym Wskaźnik nośności Wnoś (CBR) PN-S-06102:1997 załącznik A Mieszanki niezwiazane i zwiazane spoiwem hydraulicznym Wskaznik nosnosci Wnos (CBR) PN-S-06102:1997 zalacznik A","categories":["other"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków","methodology_en":"Bearing ratio Wnoś (CBR)","search_en":"Unbound and hydraulically bound mixtures Bearing ratio Wnoś (CBR) Laboratory for Testing Properties of Rocks and Stone Products; Al. Mickiewicza 30, 30-059 Kraków PN-S-06102:1997 załącznik A","test_object_en":"Unbound and hydraulically bound mixtures","lab_section_zh":"岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków","search_zh":"未结合与水硬性胶结料结合的混合料 岩石与石材制品性能检测实验室；Al. Mickiewicza 30, 30-059 Kraków PN-S-06102:1997 załącznik A","test_object_zh":"未结合与水硬性胶结料结合的混合料"}],"has_pdf":true}