{"lab":{"_id":"69ad52a3de79e566650fb185","accr_number":"AB 251","country":"PL","accr_body":"PCA","address":"Spółka z o.o., ul. Generała Sosnkowskiego 59, 14-100 Ostróda","categories":["construction","materials","environment","water"],"city":"Ostróda","imported_at":"2026-03-08T10:42:43.265Z","methods_count":36,"name":"LABORATORIUM BADAWCZE MATERIAŁÓW BUDOWLANYCH","parse_status":"parsed","parse_version":3,"pdf_files":["AB_251.pdf"],"scope_summary":"","search_text":"laboratorium badawcze materiałów budowlanych spółka z o.o., ul. generała sosnkowskiego 59, 14-100 ostróda other water construction pharma materials","status":"active","updated_at":"2026-03-08T14:51:06.734Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-18T09:01:47.630Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20251,podmiot.html","fields_of_testing":[{"codes":"J/5, J/12","pl":"Badania mechaniczne wyrobów budowlanych, szkła i ceramiki","en":"Mechanical tests of building materials, glass and ceramics"},{"codes":"N/5, N/12","pl":"Badania właściwości fizycznych wyrobów budowlanych, szkła i ceramiki","en":"Tests of physical properties of building materials, glass and ceramics"},{"codes":"O/5, O/32","pl":"Badania radiochemiczne i promieniowania – w tym nuklearne wyrobów budowlanych, materiałów budowlanych i odpadów","en":"Radiochemical tests and tests of radiation – including nuclear radiation of building products, building materials and waste"}],"issue":{"no":"25","date":"13.08.2026"},"parse_date":"2026-08-18T09:01:47.630Z","parse_source":"agent-claude-code","map_coord":[53.716697,19.991852],"map_geo":"nominatim-street","lab_locations":[{"name":"LABORATORIUM BADAWCZE MATERIAŁÓW BUDOWLANYCH","address":"ul. Generała Sosnkowskiego 59","city":null,"postal":null},{"name":"Laboratorium Badawcze Materiałów Budowlanych Spółka z o.o.","address":"ul. Generała Sosnkowskiego 59; 14-100 Ostróda","city":"Ostróda","postal":"14-100"}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/18/8dccabe71567d79e1bf0672fe39c2ae5/AB%20251.pdf","has_en":true,"category_counts":{"other":23,"construction":8,"materials":6,"environment":6,"water":5},"category_scores":{"other":11.02,"construction":1.33,"materials":0.75,"environment":0.75,"water":0.52},"has_zh":true},"methods":[{"_id":"6a841f7baf14b9c0e7b214ba","lab_id":"69ad52a3de79e566650fb185","country":"PL","accr_number":"AB 251","accr_body":"PCA","test_object":"Pustaki silikatowe wentylacyjne","methodology":"Wytrzymałość na ściskanie","parameters":[{"name":"Zakres siły","range":"(150 - 2500) kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na ściskanie\nZakres siły (150 - 2500) kN","reference":"PN-EN 772-1+A1:2015-10","norm_bases":["PN-EN 772-1+A1:2015-10"],"lab_section":"Laboratorium Badawcze Materiałów Budowlanych Spółka z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pustaki silikatowe wentylacyjne Wytrzymałość na ściskanie\nZakres siły (150 - 2500) kN PN-EN 772-1+A1:2015-10 Pustaki silikatowe wentylacyjne Wytrzymalosc na sciskanie\nZakres sily (150 - 2500) kN PN-EN 772-1+A1:2015-10","categories":["other"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Compressive strength","parameters_en":[{"name":"Force range","range":"(150 - 2500) kN"}],"search_en":"Calcium silicate ventilation blocks Compressive strength Force range PN-EN 772-1+A1:2015-10","test_object_en":"Calcium silicate ventilation blocks","methodology_zh":"抗压强度","parameters_zh":[{"name":"力值范围","range":"(150 - 2500) kN"}],"search_zh":"硅酸盐通风空心砖 抗压强度 力值范围 PN-EN 772-1+A1:2015-10","test_object_zh":"硅酸盐通风空心砖"},{"_id":"6a841f7baf14b9c0e7b214bb","lab_id":"69ad52a3de79e566650fb185","country":"PL","accr_number":"AB 251","accr_body":"PCA","test_object":"Pustaki silikatowe wentylacyjne","methodology":"Objętość drążeń, Objętość netto, Udział procentowy drążeń","parameters":[],"technique":"Metoda: napełnianie piaskiem","techniques":["Metoda: napełnianie piaskiem"],"computed":[],"activity":"Objętość drążeń, Objętość netto, Udział procentowy drążeń\nMetoda: napełnianie piaskiem","reference":"PN-EN 772-9:2006","norm_bases":["PN-EN 772-9:2006"],"lab_section":"Laboratorium Badawcze Materiałów Budowlanych Spółka z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pustaki silikatowe wentylacyjne Objętość drążeń, Objętość netto, Udział procentowy drążeń\nMetoda: napełnianie piaskiem PN-EN 772-9:2006 Pustaki silikatowe wentylacyjne Objetosc drazen, Objetosc netto, Udzial procentowy drazen\nMetoda: napelnianie piaskiem PN-EN 772-9:2006","categories":["other"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Volume of perforations, Net volume, Percentage of perforations","search_en":"Calcium silicate ventilation blocks Volume of perforations, Net volume, Percentage of perforations Method: sand filling PN-EN 772-9:2006","technique_en":"Method: sand filling","test_object_en":"Calcium silicate ventilation blocks","search_zh":"硅酸盐通风空心砖 方法：填砂法 PN-EN 772-9:2006","test_object_zh":"硅酸盐通风空心砖","technique_zh":"方法：填砂法"},{"_id":"6a841f7baf14b9c0e7b214bc","lab_id":"69ad52a3de79e566650fb185","country":"PL","accr_number":"AB 251","accr_body":"PCA","test_object":"Pustaki silikatowe wentylacyjne","methodology":"Gęstość netto w stanie suchym","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Gęstość netto w stanie suchym","reference":"PN-EN 772-13:2001","norm_bases":["PN-EN 772-13:2001"],"lab_section":"Laboratorium Badawcze Materiałów Budowlanych Spółka z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pustaki silikatowe wentylacyjne Gęstość netto w stanie suchym PN-EN 772-13:2001 Pustaki silikatowe wentylacyjne Gestosc netto w stanie suchym PN-EN 772-13:2001","categories":["other"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Net dry density","search_en":"Calcium silicate ventilation blocks Net dry density PN-EN 772-13:2001","test_object_en":"Calcium silicate ventilation blocks","search_zh":"硅酸盐通风空心砖 干态净密度 PN-EN 772-13:2001","test_object_zh":"硅酸盐通风空心砖","methodology_zh":"干态净密度"},{"_id":"6a841f7baf14b9c0e7b214bd","lab_id":"69ad52a3de79e566650fb185","country":"PL","accr_number":"AB 251","accr_body":"PCA","test_object":"Pustaki silikatowe wentylacyjne","methodology":"Masa w stanie suchym","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Masa w stanie suchym","reference":"PN-EN 772-13:2001","norm_bases":["PN-EN 772-13:2001"],"lab_section":"Laboratorium Badawcze Materiałów Budowlanych Spółka z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pustaki silikatowe wentylacyjne Masa w stanie suchym PN-EN 772-13:2001 Pustaki silikatowe wentylacyjne Masa w stanie suchym PN-EN 772-13:2001","categories":["other"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry mass","search_en":"Calcium silicate ventilation blocks Dry mass PN-EN 772-13:2001","test_object_en":"Calcium silicate ventilation blocks","search_zh":"硅酸盐通风空心砖 PN-EN 772-13:2001","test_object_zh":"硅酸盐通风空心砖"},{"_id":"6a841f7baf14b9c0e7b214be","lab_id":"69ad52a3de79e566650fb185","country":"PL","accr_number":"AB 251","accr_body":"PCA","test_object":"Pustaki silikatowe wentylacyjne","methodology":"Wymiary","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wymiary","reference":"PN-EN 772-16:2011 | PN-B-12013:2024-05 p. 5.1, p. 5.2, p. 5.3","norm_bases":["PN-EN 772-16:2011","PN-B-12013:2024-05 p. 5.1, p. 5.2, p. 5.3"],"lab_section":"Laboratorium Badawcze Materiałów Budowlanych Spółka z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pustaki silikatowe wentylacyjne Wymiary PN-EN 772-16:2011 | PN-B-12013:2024-05 p. 5.1, p. 5.2, p. 5.3 Pustaki silikatowe wentylacyjne Wymiary PN-EN 772-16:2011 | PN-B-12013:2024-05 p. 5.1, p. 5.2, p. 5.3","categories":["other"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dimensions","search_en":"Calcium silicate ventilation blocks Dimensions PN-EN 772-16:2011 | PN-B-12013:2024-05 p. 5.1, p. 5.2, p. 5.3","test_object_en":"Calcium silicate ventilation blocks","methodology_zh":"尺寸","search_zh":"硅酸盐通风空心砖 尺寸 PN-EN 772-16:2011 | PN-B-12013:2024-05 p. 5.1, p. 5.2, p. 5.3","test_object_zh":"硅酸盐通风空心砖"},{"_id":"6a841f7baf14b9c0e7b214bf","lab_id":"69ad52a3de79e566650fb185","country":"PL","accr_number":"AB 251","accr_body":"PCA","test_object":"Pustaki silikatowe wentylacyjne","methodology":"Absorpcja zimnej wody","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Absorpcja zimnej wody","reference":"PN-EN 772-21:2011","norm_bases":["PN-EN 772-21:2011"],"lab_section":"Laboratorium Badawcze Materiałów Budowlanych Spółka z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pustaki silikatowe wentylacyjne Absorpcja zimnej wody PN-EN 772-21:2011 Pustaki silikatowe wentylacyjne Absorpcja zimnej wody PN-EN 772-21:2011","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Cold water absorption","search_en":"Calcium silicate ventilation blocks Cold water absorption PN-EN 772-21:2011","test_object_en":"Calcium silicate ventilation blocks","methodology_zh":"冷水吸水率","search_zh":"硅酸盐通风空心砖 冷水吸水率 PN-EN 772-21:2011","test_object_zh":"硅酸盐通风空心砖"},{"_id":"6a841f7baf14b9c0e7b214c0","lab_id":"69ad52a3de79e566650fb185","country":"PL","accr_number":"AB 251","accr_body":"PCA","test_object":"Pustaki ceramiczne wentylacyjne","methodology":"Wytrzymałość na ściskanie","parameters":[{"name":"Zakres siły","range":"(150 - 2500) kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na ściskanie\nZakres siły (150 - 2500) kN","reference":"PN-EN 772-1+A1:2015-10","norm_bases":["PN-EN 772-1+A1:2015-10"],"lab_section":"Laboratorium Badawcze Materiałów Budowlanych Spółka z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pustaki ceramiczne wentylacyjne Wytrzymałość na ściskanie\nZakres siły (150 - 2500) kN PN-EN 772-1+A1:2015-10 Pustaki ceramiczne wentylacyjne Wytrzymalosc na sciskanie\nZakres sily (150 - 2500) kN PN-EN 772-1+A1:2015-10","categories":["other"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Compressive strength","parameters_en":[{"name":"Force range","range":"(150 - 2500) kN"}],"search_en":"Ceramic ventilation blocks Compressive strength Force range PN-EN 772-1+A1:2015-10","test_object_en":"Ceramic ventilation blocks","methodology_zh":"抗压强度","parameters_zh":[{"name":"力值范围","range":"(150 - 2500) kN"}],"search_zh":"陶瓷通风空心砖 抗压强度 力值范围 PN-EN 772-1+A1:2015-10","test_object_zh":"陶瓷通风空心砖"},{"_id":"6a841f7baf14b9c0e7b214c1","lab_id":"69ad52a3de79e566650fb185","country":"PL","accr_number":"AB 251","accr_body":"PCA","test_object":"Pustaki ceramiczne wentylacyjne","methodology":"Objętość drążeń, Objętość netto, Udział procentowy drążeń","parameters":[],"technique":"Metoda: objętość netto: ważenie hydrostatyczne","techniques":["Metoda: objętość netto: ważenie hydrostatyczne"],"computed":[],"activity":"Objętość drążeń, Objętość netto, Udział procentowy drążeń\nMetoda: objętość netto: ważenie hydrostatyczne","reference":"PN-EN 772-3:2000","norm_bases":["PN-EN 772-3:2000"],"lab_section":"Laboratorium Badawcze Materiałów Budowlanych Spółka z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pustaki ceramiczne wentylacyjne Objętość drążeń, Objętość netto, Udział procentowy drążeń\nMetoda: objętość netto: ważenie hydrostatyczne PN-EN 772-3:2000 Pustaki ceramiczne wentylacyjne Objetosc drazen, Objetosc netto, Udzial procentowy drazen\nMetoda: objetosc netto: wazenie hydrostatyczne PN-EN 772-3:2000","categories":["other"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Volume of perforations, Net volume, Percentage of perforations","search_en":"Ceramic ventilation blocks Volume of perforations, Net volume, Percentage of perforations Method: net volume: hydrostatic weighing PN-EN 772-3:2000","technique_en":"Method: net volume: hydrostatic weighing","test_object_en":"Ceramic ventilation blocks","search_zh":"陶瓷通风空心砖 PN-EN 772-3:2000","test_object_zh":"陶瓷通风空心砖"},{"_id":"6a841f7baf14b9c0e7b214c2","lab_id":"69ad52a3de79e566650fb185","country":"PL","accr_number":"AB 251","accr_body":"PCA","test_object":"Pustaki ceramiczne wentylacyjne","methodology":"Gęstość netto w stanie suchym","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Gęstość netto w stanie suchym","reference":"PN-EN 772-13:2001","norm_bases":["PN-EN 772-13:2001"],"lab_section":"Laboratorium Badawcze Materiałów Budowlanych Spółka z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pustaki ceramiczne wentylacyjne Gęstość netto w stanie suchym PN-EN 772-13:2001 Pustaki ceramiczne wentylacyjne Gestosc netto w stanie suchym PN-EN 772-13:2001","categories":["other"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Net dry density","search_en":"Ceramic ventilation blocks Net dry density PN-EN 772-13:2001","test_object_en":"Ceramic ventilation blocks","search_zh":"陶瓷通风空心砖 干态净密度 PN-EN 772-13:2001","test_object_zh":"陶瓷通风空心砖","methodology_zh":"干态净密度"},{"_id":"6a841f7baf14b9c0e7b214c3","lab_id":"69ad52a3de79e566650fb185","country":"PL","accr_number":"AB 251","accr_body":"PCA","test_object":"Pustaki ceramiczne wentylacyjne","methodology":"Masa w stanie suchym","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Masa w stanie suchym","reference":"PN-EN 772-13:2001","norm_bases":["PN-EN 772-13:2001"],"lab_section":"Laboratorium Badawcze Materiałów Budowlanych Spółka z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pustaki ceramiczne wentylacyjne Masa w stanie suchym PN-EN 772-13:2001 Pustaki ceramiczne wentylacyjne Masa w stanie suchym PN-EN 772-13:2001","categories":["other"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry mass","search_en":"Ceramic ventilation blocks Dry mass PN-EN 772-13:2001","test_object_en":"Ceramic ventilation blocks","search_zh":"陶瓷通风空心砖 PN-EN 772-13:2001","test_object_zh":"陶瓷通风空心砖"},{"_id":"6a841f7baf14b9c0e7b214c4","lab_id":"69ad52a3de79e566650fb185","country":"PL","accr_number":"AB 251","accr_body":"PCA","test_object":"Pustaki ceramiczne wentylacyjne","methodology":"Wymiary","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wymiary","reference":"PN-EN 772-16:2011 | PN-B 12014:2023-07 p. 5.1, p. 5.2, p. 5.3","norm_bases":["PN-EN 772-16:2011","PN-B 12014:2023-07 p. 5.1, p. 5.2, p. 5.3"],"lab_section":"Laboratorium Badawcze Materiałów Budowlanych Spółka z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pustaki ceramiczne wentylacyjne Wymiary PN-EN 772-16:2011 | PN-B 12014:2023-07 p. 5.1, p. 5.2, p. 5.3 Pustaki ceramiczne wentylacyjne Wymiary PN-EN 772-16:2011 | PN-B 12014:2023-07 p. 5.1, p. 5.2, p. 5.3","categories":["other"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dimensions","search_en":"Ceramic ventilation blocks Dimensions PN-EN 772-16:2011 | PN-B 12014:2023-07 p. 5.1, p. 5.2, p. 5.3","test_object_en":"Ceramic ventilation blocks","methodology_zh":"尺寸","search_zh":"陶瓷通风空心砖 尺寸 PN-EN 772-16:2011 | PN-B 12014:2023-07 p. 5.1, p. 5.2, p. 5.3","test_object_zh":"陶瓷通风空心砖"},{"_id":"6a841f7baf14b9c0e7b214c5","lab_id":"69ad52a3de79e566650fb185","country":"PL","accr_number":"AB 251","accr_body":"PCA","test_object":"Pustaki ceramiczne wentylacyjne","methodology":"Absorpcja zimnej wody","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Absorpcja zimnej wody","reference":"PN-EN 772-21:2011","norm_bases":["PN-EN 772-21:2011"],"lab_section":"Laboratorium Badawcze Materiałów Budowlanych Spółka z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pustaki ceramiczne wentylacyjne Absorpcja zimnej wody PN-EN 772-21:2011 Pustaki ceramiczne wentylacyjne Absorpcja zimnej wody PN-EN 772-21:2011","categories":["water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Cold water absorption","search_en":"Ceramic ventilation blocks Cold water absorption PN-EN 772-21:2011","test_object_en":"Ceramic ventilation blocks","search_zh":"陶瓷通风空心砖 冷水吸水率 PN-EN 772-21:2011","test_object_zh":"陶瓷通风空心砖","methodology_zh":"冷水吸水率"},{"_id":"6a841f7baf14b9c0e7b214c6","lab_id":"69ad52a3de79e566650fb185","country":"PL","accr_number":"AB 251","accr_body":"PCA","test_object":"Elementy murowe z betonu kruszywowego / z kruszywami zwykłymi i lekkimi /","methodology":"Wytrzymałość na ściskanie","parameters":[{"name":"Zakres siły","range":"(150 - 2500) kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na ściskanie\nZakres siły (150 - 2500) kN","reference":"PN-EN 772-1+A1:2015-10","norm_bases":["PN-EN 772-1+A1:2015-10"],"lab_section":"Laboratorium Badawcze Materiałów Budowlanych Spółka z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elementy murowe z betonu kruszywowego / z kruszywami zwykłymi i lekkimi / Wytrzymałość na ściskanie\nZakres siły (150 - 2500) kN PN-EN 772-1+A1:2015-10 Elementy murowe z betonu kruszywowego / z kruszywami zwyklymi i lekkimi / Wytrzymalosc na sciskanie\nZakres sily (150 - 2500) kN PN-EN 772-1+A1:2015-10","categories":["construction"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Compressive strength","parameters_en":[{"name":"Force range","range":"(150 - 2500) kN"}],"search_en":"Aggregate concrete masonry units / with dense and lightweight aggregates / Compressive strength Force range PN-EN 772-1+A1:2015-10","test_object_en":"Aggregate concrete masonry units / with dense and lightweight aggregates /","methodology_zh":"抗压强度","parameters_zh":[{"name":"力值范围","range":"(150 - 2500) kN"}],"search_zh":"抗压强度 力值范围 PN-EN 772-1+A1:2015-10"},{"_id":"6a841f7baf14b9c0e7b214c7","lab_id":"69ad52a3de79e566650fb185","country":"PL","accr_number":"AB 251","accr_body":"PCA","test_object":"Elementy murowe z betonu kruszywowego / z kruszywami zwykłymi i lekkimi /","methodology":"Wymiary","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wymiary","reference":"PN-EN 772-16:2011","norm_bases":["PN-EN 772-16:2011"],"lab_section":"Laboratorium Badawcze Materiałów Budowlanych Spółka z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elementy murowe z betonu kruszywowego / z kruszywami zwykłymi i lekkimi / Wymiary PN-EN 772-16:2011 Elementy murowe z betonu kruszywowego / z kruszywami zwyklymi i lekkimi / Wymiary PN-EN 772-16:2011","categories":["construction"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dimensions","search_en":"Aggregate concrete masonry units / with dense and lightweight aggregates / Dimensions PN-EN 772-16:2011","test_object_en":"Aggregate concrete masonry units / with dense and lightweight aggregates /","methodology_zh":"尺寸","search_zh":"尺寸 PN-EN 772-16:2011"},{"_id":"6a841f7baf14b9c0e7b214c8","lab_id":"69ad52a3de79e566650fb185","country":"PL","accr_number":"AB 251","accr_body":"PCA","test_object":"Elementy murowe silikatowe","methodology":"Wytrzymałość na ściskanie","parameters":[{"name":"Zakres siły","range":"(150 - 2500) kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na ściskanie\nZakres siły (150 - 2500) kN","reference":"PN-EN 772-1+A1:2015-10","norm_bases":["PN-EN 772-1+A1:2015-10"],"lab_section":"Laboratorium Badawcze Materiałów Budowlanych Spółka z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elementy murowe silikatowe Wytrzymałość na ściskanie\nZakres siły (150 - 2500) kN PN-EN 772-1+A1:2015-10 Elementy murowe silikatowe Wytrzymalosc na sciskanie\nZakres sily (150 - 2500) kN PN-EN 772-1+A1:2015-10","categories":["other"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Compressive strength","parameters_en":[{"name":"Force range","range":"(150 - 2500) kN"}],"search_en":"Calcium silicate masonry units Compressive strength Force range PN-EN 772-1+A1:2015-10","test_object_en":"Calcium silicate masonry units","methodology_zh":"抗压强度","parameters_zh":[{"name":"力值范围","range":"(150 - 2500) kN"}],"search_zh":"硅酸盐砌块 抗压强度 力值范围 PN-EN 772-1+A1:2015-10","test_object_zh":"硅酸盐砌块"},{"_id":"6a841f7baf14b9c0e7b214c9","lab_id":"69ad52a3de79e566650fb185","country":"PL","accr_number":"AB 251","accr_body":"PCA","test_object":"Elementy murowe silikatowe","methodology":"Objętość brutto, Objętość drążeń, Objętość netto, Udział procentowy drążeń","parameters":[],"technique":"Metoda: napełnianie piaskiem","techniques":["Metoda: napełnianie piaskiem"],"computed":[],"activity":"Objętość brutto, Objętość drążeń, Objętość netto, Udział procentowy drążeń\nMetoda: napełnianie piaskiem","reference":"PN-EN 772-9:2006","norm_bases":["PN-EN 772-9:2006"],"lab_section":"Laboratorium Badawcze Materiałów Budowlanych Spółka z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elementy murowe silikatowe Objętość brutto, Objętość drążeń, Objętość netto, Udział procentowy drążeń\nMetoda: napełnianie piaskiem PN-EN 772-9:2006 Elementy murowe silikatowe Objetosc brutto, Objetosc drazen, Objetosc netto, Udzial procentowy drazen\nMetoda: napelnianie piaskiem PN-EN 772-9:2006","categories":["other"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gross volume, Volume of voids, Net volume, Percentage of voids","search_en":"Calcium silicate masonry units Gross volume, Volume of voids, Net volume, Percentage of voids Method: sand filling PN-EN 772-9:2006","technique_en":"Method: sand filling","test_object_en":"Calcium silicate masonry units","search_zh":"硅酸盐砌块 毛体积、孔洞体积、净体积、孔洞百分率 方法：填砂法 PN-EN 772-9:2006","test_object_zh":"硅酸盐砌块","methodology_zh":"毛体积、孔洞体积、净体积、孔洞百分率","technique_zh":"方法：填砂法"},{"_id":"6a841f7baf14b9c0e7b214ca","lab_id":"69ad52a3de79e566650fb185","country":"PL","accr_number":"AB 251","accr_body":"PCA","test_object":"Elementy murowe silikatowe","methodology":"Gęstość netto w stanie suchym, Gęstość brutto w stanie suchym","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Gęstość netto w stanie suchym, Gęstość brutto w stanie suchym","reference":"PN-EN 772-13:2001","norm_bases":["PN-EN 772-13:2001"],"lab_section":"Laboratorium Badawcze Materiałów Budowlanych Spółka z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elementy murowe silikatowe Gęstość netto w stanie suchym, Gęstość brutto w stanie suchym PN-EN 772-13:2001 Elementy murowe silikatowe Gestosc netto w stanie suchym, Gestosc brutto w stanie suchym PN-EN 772-13:2001","categories":["other"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Net dry density, Gross dry density","search_en":"Calcium silicate masonry units Net dry density, Gross dry density PN-EN 772-13:2001","test_object_en":"Calcium silicate masonry units","search_zh":"硅酸盐砌块 PN-EN 772-13:2001","test_object_zh":"硅酸盐砌块"},{"_id":"6a841f7baf14b9c0e7b214cb","lab_id":"69ad52a3de79e566650fb185","country":"PL","accr_number":"AB 251","accr_body":"PCA","test_object":"Elementy murowe silikatowe","methodology":"Wymiary","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wymiary","reference":"PN-EN 772-16:2011","norm_bases":["PN-EN 772-16:2011"],"lab_section":"Laboratorium Badawcze Materiałów Budowlanych Spółka z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elementy murowe silikatowe Wymiary PN-EN 772-16:2011 Elementy murowe silikatowe Wymiary PN-EN 772-16:2011","categories":["other"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dimensions","search_en":"Calcium silicate masonry units Dimensions PN-EN 772-16:2011","test_object_en":"Calcium silicate masonry units","methodology_zh":"尺寸","search_zh":"硅酸盐砌块 尺寸 PN-EN 772-16:2011","test_object_zh":"硅酸盐砌块"},{"_id":"6a841f7baf14b9c0e7b214cc","lab_id":"69ad52a3de79e566650fb185","country":"PL","accr_number":"AB 251","accr_body":"PCA","test_object":"Elementy murowe silikatowe","methodology":"Odporność na zamrażanie – odmrażanie","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na zamrażanie – odmrażanie","reference":"PN-EN 772-18:2011","norm_bases":["PN-EN 772-18:2011"],"lab_section":"Laboratorium Badawcze Materiałów Budowlanych Spółka z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elementy murowe silikatowe Odporność na zamrażanie – odmrażanie PN-EN 772-18:2011 Elementy murowe silikatowe Odpornosc na zamrazanie – odmrazanie PN-EN 772-18:2011","categories":["other"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Freeze-thaw resistance","search_en":"Calcium silicate masonry units Freeze-thaw resistance PN-EN 772-18:2011","test_object_en":"Calcium silicate masonry units","search_zh":"硅酸盐砌块 PN-EN 772-18:2011","test_object_zh":"硅酸盐砌块"},{"_id":"6a841f7baf14b9c0e7b214cd","lab_id":"69ad52a3de79e566650fb185","country":"PL","accr_number":"AB 251","accr_body":"PCA","test_object":"Elementy murowe silikatowe","methodology":"Absorpcja zimnej wody","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Absorpcja zimnej wody","reference":"PN-EN 772-21:2011","norm_bases":["PN-EN 772-21:2011"],"lab_section":"Laboratorium Badawcze Materiałów Budowlanych Spółka z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elementy murowe silikatowe Absorpcja zimnej wody PN-EN 772-21:2011 Elementy murowe silikatowe Absorpcja zimnej wody PN-EN 772-21:2011","categories":["water"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Cold water absorption","search_en":"Calcium silicate masonry units Cold water absorption PN-EN 772-21:2011","test_object_en":"Calcium silicate masonry units","search_zh":"硅酸盐砌块 冷水吸水率 PN-EN 772-21:2011","test_object_zh":"硅酸盐砌块","methodology_zh":"冷水吸水率"},{"_id":"6a841f7baf14b9c0e7b214ce","lab_id":"69ad52a3de79e566650fb185","country":"PL","accr_number":"AB 251","accr_body":"PCA","test_object":"Elementy murowe silikatowe","methodology":"Płaskość powierzchni","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Płaskość powierzchni","reference":"PN-EN 772-20:2002 | PN-EN 772-20:2002/A1:2005","norm_bases":["PN-EN 772-20:2002","PN-EN 772-20:2002/A1:2005"],"lab_section":"Laboratorium Badawcze Materiałów Budowlanych Spółka z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elementy murowe silikatowe Płaskość powierzchni PN-EN 772-20:2002 | PN-EN 772-20:2002/A1:2005 Elementy murowe silikatowe Plaskosc powierzchni PN-EN 772-20:2002 | PN-EN 772-20:2002/A1:2005","categories":["other"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Surface flatness","search_en":"Calcium silicate masonry units Surface flatness PN-EN 772-20:2002 | PN-EN 772-20:2002/A1:2005","test_object_en":"Calcium silicate masonry units","search_zh":"硅酸盐砌块 表面平整度 PN-EN 772-20:2002 | PN-EN 772-20:2002/A1:2005","test_object_zh":"硅酸盐砌块","methodology_zh":"表面平整度"},{"_id":"6a841f7baf14b9c0e7b214cf","lab_id":"69ad52a3de79e566650fb185","country":"PL","accr_number":"AB 251","accr_body":"PCA","test_object":"Elementy murowe ceramiczne","methodology":"Wytrzymałość na ściskanie","parameters":[{"name":"Zakres siły","range":"(150 - 2500) kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na ściskanie\nZakres siły (150 - 2500) kN","reference":"PN-EN 772-1+A1:2015-10","norm_bases":["PN-EN 772-1+A1:2015-10"],"lab_section":"Laboratorium Badawcze Materiałów Budowlanych Spółka z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elementy murowe ceramiczne Wytrzymałość na ściskanie\nZakres siły (150 - 2500) kN PN-EN 772-1+A1:2015-10 Elementy murowe ceramiczne Wytrzymalosc na sciskanie\nZakres sily (150 - 2500) kN PN-EN 772-1+A1:2015-10","categories":["other"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Compressive strength","parameters_en":[{"name":"Force range","range":"(150 - 2500) kN"}],"search_en":"Clay masonry units Compressive strength Force range PN-EN 772-1+A1:2015-10","test_object_en":"Clay masonry units","methodology_zh":"抗压强度","parameters_zh":[{"name":"力值范围","range":"(150 - 2500) kN"}],"search_zh":"烧结黏土砌块 抗压强度 力值范围 PN-EN 772-1+A1:2015-10","test_object_zh":"烧结黏土砌块"},{"_id":"6a841f7baf14b9c0e7b214d0","lab_id":"69ad52a3de79e566650fb185","country":"PL","accr_number":"AB 251","accr_body":"PCA","test_object":"Elementy murowe ceramiczne","methodology":"Objętość brutto, Objętość drążeń, Objętość netto, Udział procentowy drążeń","parameters":[],"technique":"Metoda: objętość netto: ważenie hydrostatyczne","techniques":["Metoda: objętość netto: ważenie hydrostatyczne"],"computed":[],"activity":"Objętość brutto, Objętość drążeń, Objętość netto, Udział procentowy drążeń\nMetoda: objętość netto: ważenie hydrostatyczne","reference":"PN-EN 772-3:2000","norm_bases":["PN-EN 772-3:2000"],"lab_section":"Laboratorium Badawcze Materiałów Budowlanych Spółka z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elementy murowe ceramiczne Objętość brutto, Objętość drążeń, Objętość netto, Udział procentowy drążeń\nMetoda: objętość netto: ważenie hydrostatyczne PN-EN 772-3:2000 Elementy murowe ceramiczne Objetosc brutto, Objetosc drazen, Objetosc netto, Udzial procentowy drazen\nMetoda: objetosc netto: wazenie hydrostatyczne PN-EN 772-3:2000","categories":["other"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gross volume, Volume of voids, Net volume, Percentage of voids","search_en":"Clay masonry units Gross volume, Volume of voids, Net volume, Percentage of voids Method: net volume: hydrostatic weighing PN-EN 772-3:2000","technique_en":"Method: net volume: hydrostatic weighing","test_object_en":"Clay masonry units","search_zh":"烧结黏土砌块 毛体积、孔洞体积、净体积、孔洞百分率 PN-EN 772-3:2000","test_object_zh":"烧结黏土砌块","methodology_zh":"毛体积、孔洞体积、净体积、孔洞百分率"},{"_id":"6a841f7baf14b9c0e7b214d1","lab_id":"69ad52a3de79e566650fb185","country":"PL","accr_number":"AB 251","accr_body":"PCA","test_object":"Elementy murowe ceramiczne","methodology":"Absorpcja zimnej wody","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Absorpcja zimnej wody","reference":"PN-EN 772-21:2011","norm_bases":["PN-EN 772-21:2011"],"lab_section":"Laboratorium Badawcze Materiałów Budowlanych Spółka z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elementy murowe ceramiczne Absorpcja zimnej wody PN-EN 772-21:2011 Elementy murowe ceramiczne Absorpcja zimnej wody PN-EN 772-21:2011","categories":["water"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Cold water absorption","search_en":"Clay masonry units Cold water absorption PN-EN 772-21:2011","test_object_en":"Clay masonry units","search_zh":"烧结黏土砌块 冷水吸水率 PN-EN 772-21:2011","test_object_zh":"烧结黏土砌块","methodology_zh":"冷水吸水率"},{"_id":"6a841f7baf14b9c0e7b214d2","lab_id":"69ad52a3de79e566650fb185","country":"PL","accr_number":"AB 251","accr_body":"PCA","test_object":"Elementy murowe ceramiczne","methodology":"Początkowa absorpcja wody","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Początkowa absorpcja wody","reference":"PN-EN 772-11:2011","norm_bases":["PN-EN 772-11:2011"],"lab_section":"Laboratorium Badawcze Materiałów Budowlanych Spółka z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elementy murowe ceramiczne Początkowa absorpcja wody PN-EN 772-11:2011 Elementy murowe ceramiczne Poczatkowa absorpcja wody PN-EN 772-11:2011","categories":["water"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Initial water absorption","search_en":"Clay masonry units Initial water absorption PN-EN 772-11:2011","test_object_en":"Clay masonry units","search_zh":"烧结黏土砌块 初始吸水率 PN-EN 772-11:2011","test_object_zh":"烧结黏土砌块","methodology_zh":"初始吸水率"},{"_id":"6a841f7baf14b9c0e7b214d3","lab_id":"69ad52a3de79e566650fb185","country":"PL","accr_number":"AB 251","accr_body":"PCA","test_object":"Elementy murowe ceramiczne","methodology":"Gęstość netto w stanie suchym, Gęstość brutto w stanie suchym","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Gęstość netto w stanie suchym, Gęstość brutto w stanie suchym","reference":"PN-EN 772-13:2001","norm_bases":["PN-EN 772-13:2001"],"lab_section":"Laboratorium Badawcze Materiałów Budowlanych Spółka z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elementy murowe ceramiczne Gęstość netto w stanie suchym, Gęstość brutto w stanie suchym PN-EN 772-13:2001 Elementy murowe ceramiczne Gestosc netto w stanie suchym, Gestosc brutto w stanie suchym PN-EN 772-13:2001","categories":["other"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Net dry density, Gross dry density","search_en":"Clay masonry units Net dry density, Gross dry density PN-EN 772-13:2001","test_object_en":"Clay masonry units","search_zh":"烧结黏土砌块 PN-EN 772-13:2001","test_object_zh":"烧结黏土砌块"},{"_id":"6a841f7baf14b9c0e7b214d4","lab_id":"69ad52a3de79e566650fb185","country":"PL","accr_number":"AB 251","accr_body":"PCA","test_object":"Elementy murowe ceramiczne","methodology":"Wymiary","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wymiary","reference":"PN-EN 772-16:2011","norm_bases":["PN-EN 772-16:2011"],"lab_section":"Laboratorium Badawcze Materiałów Budowlanych Spółka z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elementy murowe ceramiczne Wymiary PN-EN 772-16:2011 Elementy murowe ceramiczne Wymiary PN-EN 772-16:2011","categories":["other"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dimensions","search_en":"Clay masonry units Dimensions PN-EN 772-16:2011","test_object_en":"Clay masonry units","methodology_zh":"尺寸","search_zh":"烧结黏土砌块 尺寸 PN-EN 772-16:2011","test_object_zh":"烧结黏土砌块"},{"_id":"6a841f7baf14b9c0e7b214d5","lab_id":"69ad52a3de79e566650fb185","country":"PL","accr_number":"AB 251","accr_body":"PCA","test_object":"Elementy murowe ceramiczne","methodology":"Płaskość powierzchni","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Płaskość powierzchni","reference":"PN-EN 772-20:2002 | PN-EN 772-20:2002/A1:2005","norm_bases":["PN-EN 772-20:2002","PN-EN 772-20:2002/A1:2005"],"lab_section":"Laboratorium Badawcze Materiałów Budowlanych Spółka z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elementy murowe ceramiczne Płaskość powierzchni PN-EN 772-20:2002 | PN-EN 772-20:2002/A1:2005 Elementy murowe ceramiczne Plaskosc powierzchni PN-EN 772-20:2002 | PN-EN 772-20:2002/A1:2005","categories":["other"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Surface flatness","search_en":"Clay masonry units Surface flatness PN-EN 772-20:2002 | PN-EN 772-20:2002/A1:2005","test_object_en":"Clay masonry units","search_zh":"烧结黏土砌块 表面平整度 PN-EN 772-20:2002 | PN-EN 772-20:2002/A1:2005","test_object_zh":"烧结黏土砌块","methodology_zh":"表面平整度"},{"_id":"6a841f7baf14b9c0e7b214d6","lab_id":"69ad52a3de79e566650fb185","country":"PL","accr_number":"AB 251","accr_body":"PCA","test_object":"Elementy murowe ceramiczne","methodology":"Objętość brutto, Objętość drążeń, Objętość netto, Udział procentowy drążeń","parameters":[],"technique":"Metoda: napełnianie piaskiem","techniques":["Metoda: napełnianie piaskiem"],"computed":[],"activity":"Objętość brutto, Objętość drążeń, Objętość netto, Udział procentowy drążeń\nMetoda: napełnianie piaskiem","reference":"PN-EN 772-9:2006","norm_bases":["PN-EN 772-9:2006"],"lab_section":"Laboratorium Badawcze Materiałów Budowlanych Spółka z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elementy murowe ceramiczne Objętość brutto, Objętość drążeń, Objętość netto, Udział procentowy drążeń\nMetoda: napełnianie piaskiem PN-EN 772-9:2006 Elementy murowe ceramiczne Objetosc brutto, Objetosc drazen, Objetosc netto, Udzial procentowy drazen\nMetoda: napelnianie piaskiem PN-EN 772-9:2006","categories":["other"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gross volume, Volume of voids, Net volume, Percentage of voids","search_en":"Clay masonry units Gross volume, Volume of voids, Net volume, Percentage of voids Method: sand filling PN-EN 772-9:2006","technique_en":"Method: sand filling","test_object_en":"Clay masonry units","search_zh":"烧结黏土砌块 毛体积、孔洞体积、净体积、孔洞百分率 方法：填砂法 PN-EN 772-9:2006","test_object_zh":"烧结黏土砌块","methodology_zh":"毛体积、孔洞体积、净体积、孔洞百分率","technique_zh":"方法：填砂法"},{"_id":"6a841f7baf14b9c0e7b214d7","lab_id":"69ad52a3de79e566650fb185","country":"PL","accr_number":"AB 251","accr_body":"PCA","test_object":"Elementy murowe ceramiczne","methodology":"Odporność na zamrażanie - odmrażanie","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na zamrażanie - odmrażanie","reference":"PN-B-12012:2022-07 | PN-EN 772-22:2019-01","norm_bases":["PN-B-12012:2022-07","PN-EN 772-22:2019-01"],"lab_section":"Laboratorium Badawcze Materiałów Budowlanych Spółka z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elementy murowe ceramiczne Odporność na zamrażanie - odmrażanie PN-B-12012:2022-07 | PN-EN 772-22:2019-01 Elementy murowe ceramiczne Odpornosc na zamrazanie - odmrazanie PN-B-12012:2022-07 | PN-EN 772-22:2019-01","categories":["other"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Freeze-thaw resistance","search_en":"Clay masonry units Freeze-thaw resistance PN-B-12012:2022-07 | PN-EN 772-22:2019-01","test_object_en":"Clay masonry units","search_zh":"烧结黏土砌块 抗冻融性 PN-B-12012:2022-07 | PN-EN 772-22:2019-01","test_object_zh":"烧结黏土砌块","methodology_zh":"抗冻融性"},{"_id":"6a841f7baf14b9c0e7b214d8","lab_id":"69ad52a3de79e566650fb185","country":"PL","accr_number":"AB 251","accr_body":"PCA","test_object":"Materiały i surowce budowlane, Odpady O) kod: 10 01 01, 10 01 02","methodology":"Stężenie aktywności radionuklidu: 40K","parameters":[{"name":"Zakres","range":"(50 – 9000) Bq/kg"}],"technique":"Metoda spektrometrii promieniowania gamma","techniques":["Metoda spektrometrii promieniowania gamma"],"computed":[],"activity":"Stężenie aktywności radionuklidu: 40K\nZakres (50 – 9000) Bq/kg\nMetoda spektrometrii promieniowania gamma","reference":"Poradnik ITB nr 455/2010 | PB-01 edycja 1 z dnia 24.02.2021","norm_bases":["Poradnik ITB nr 455/2010","PB-01 edycja 1 z dnia 24.02.2021"],"lab_section":"Laboratorium Badawcze Materiałów Budowlanych Spółka z o.o.","lab_address":null,"regulatory_area":"Kod odpadów podany według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Materiały i surowce budowlane, Odpady O) kod: 10 01 01, 10 01 02 Stężenie aktywności radionuklidu: 40K\nZakres (50 – 9000) Bq/kg\nMetoda spektrometrii promieniowania gamma Poradnik ITB nr 455/2010 | PB-01 edycja 1 z dnia 24.02.2021 Materialy i surowce budowlane, Odpady O) kod: 10 01 01, 10 01 02 Stezenie aktywnosci radionuklidu: 40K\nZakres (50 – 9000) Bq/kg\nMetoda spektrometrii promieniowania gamma Poradnik ITB nr 455/2010 | PB-01 edycja 1 z dnia 24.02.2021","categories":["materials","environment","construction"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Activity concentration of the radionuclide: 40K","parameters_en":[{"name":"Range","range":"(50 – 9000) Bq/kg"}],"search_en":"Activity concentration of the radionuclide: 40K Gamma-ray spectrometry method Range Poradnik ITB nr 455/2010 | PB-01 edycja 1 z dnia 24.02.2021","technique_en":"Gamma-ray spectrometry method","parameters_zh":[{"name":"范围","range":"(50 – 9000) Bq/kg"}],"search_zh":"γ 能谱法 范围 Poradnik ITB nr 455/2010 | PB-01 edycja 1 z dnia 24.02.2021","technique_zh":"γ 能谱法"},{"_id":"6a841f7baf14b9c0e7b214d9","lab_id":"69ad52a3de79e566650fb185","country":"PL","accr_number":"AB 251","accr_body":"PCA","test_object":"Materiały i surowce budowlane, Odpady O) kod: 10 01 01, 10 01 02","methodology":"Stężenie aktywności radionuklidu: 214 Bi","parameters":[{"name":"Zakres","range":"(15 – 5000) Bq/kg"}],"technique":"Metoda spektrometrii promieniowania gamma","techniques":["Metoda spektrometrii promieniowania gamma"],"computed":[],"activity":"Stężenie aktywności radionuklidu: 214 Bi\nZakres (15 – 5000) Bq/kg\nMetoda spektrometrii promieniowania gamma","reference":"Poradnik ITB nr 455/2010 | PB-01 edycja 1 z dnia 24.02.2021","norm_bases":["Poradnik ITB nr 455/2010","PB-01 edycja 1 z dnia 24.02.2021"],"lab_section":"Laboratorium Badawcze Materiałów Budowlanych Spółka z o.o.","lab_address":null,"regulatory_area":"Kod odpadów podany według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Materiały i surowce budowlane, Odpady O) kod: 10 01 01, 10 01 02 Stężenie aktywności radionuklidu: 214 Bi\nZakres (15 – 5000) Bq/kg\nMetoda spektrometrii promieniowania gamma Poradnik ITB nr 455/2010 | PB-01 edycja 1 z dnia 24.02.2021 Materialy i surowce budowlane, Odpady O) kod: 10 01 01, 10 01 02 Stezenie aktywnosci radionuklidu: 214 Bi\nZakres (15 – 5000) Bq/kg\nMetoda spektrometrii promieniowania gamma Poradnik ITB nr 455/2010 | PB-01 edycja 1 z dnia 24.02.2021","categories":["materials","environment","construction"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(15 – 5000) Bq/kg"}],"search_en":"Gamma-ray spectrometry method Range Poradnik ITB nr 455/2010 | PB-01 edycja 1 z dnia 24.02.2021","technique_en":"Gamma-ray spectrometry method","parameters_zh":[{"name":"范围","range":"(15 – 5000) Bq/kg"}],"search_zh":"γ 能谱法 范围 Poradnik ITB nr 455/2010 | PB-01 edycja 1 z dnia 24.02.2021","technique_zh":"γ 能谱法"},{"_id":"6a841f7baf14b9c0e7b214da","lab_id":"69ad52a3de79e566650fb185","country":"PL","accr_number":"AB 251","accr_body":"PCA","test_object":"Materiały i surowce budowlane, Odpady O) kod: 10 01 01, 10 01 02","methodology":"Stężenie aktywności radionuklidu: 208 Tl","parameters":[{"name":"Zakres","range":"(10 – 5000) Bq/kg"}],"technique":"Metoda spektrometrii promieniowania gamma","techniques":["Metoda spektrometrii promieniowania gamma"],"computed":[],"activity":"Stężenie aktywności radionuklidu: 208 Tl\nZakres (10 – 5000) Bq/kg\nMetoda spektrometrii promieniowania gamma","reference":"Poradnik ITB nr 455/2010 | PB-01 edycja 1 z dnia 24.02.2021","norm_bases":["Poradnik ITB nr 455/2010","PB-01 edycja 1 z dnia 24.02.2021"],"lab_section":"Laboratorium Badawcze Materiałów Budowlanych Spółka z o.o.","lab_address":null,"regulatory_area":"Kod odpadów podany według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Materiały i surowce budowlane, Odpady O) kod: 10 01 01, 10 01 02 Stężenie aktywności radionuklidu: 208 Tl\nZakres (10 – 5000) Bq/kg\nMetoda spektrometrii promieniowania gamma Poradnik ITB nr 455/2010 | PB-01 edycja 1 z dnia 24.02.2021 Materialy i surowce budowlane, Odpady O) kod: 10 01 01, 10 01 02 Stezenie aktywnosci radionuklidu: 208 Tl\nZakres (10 – 5000) Bq/kg\nMetoda spektrometrii promieniowania gamma Poradnik ITB nr 455/2010 | PB-01 edycja 1 z dnia 24.02.2021","categories":["materials","environment","construction"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(10 – 5000) Bq/kg"}],"search_en":"Gamma-ray spectrometry method Range Poradnik ITB nr 455/2010 | PB-01 edycja 1 z dnia 24.02.2021","technique_en":"Gamma-ray spectrometry method","parameters_zh":[{"name":"范围","range":"(10 – 5000) Bq/kg"}],"search_zh":"γ 能谱法 范围 Poradnik ITB nr 455/2010 | PB-01 edycja 1 z dnia 24.02.2021","technique_zh":"γ 能谱法"},{"_id":"6a841f7baf14b9c0e7b214db","lab_id":"69ad52a3de79e566650fb185","country":"PL","accr_number":"AB 251","accr_body":"PCA","test_object":"Materiały i surowce budowlane, Odpady O) kod: 10 01 01, 10 01 02","methodology":"Stężenie aktywności radionuklidu: 226 Ra (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie aktywności radionuklidu: 226 Ra (z obliczeń)","reference":"Poradnik ITB nr 455/2010 | PB-01 edycja 1 z dnia 24.02.2021","norm_bases":["Poradnik ITB nr 455/2010","PB-01 edycja 1 z dnia 24.02.2021"],"lab_section":"Laboratorium Badawcze Materiałów Budowlanych Spółka z o.o.","lab_address":null,"regulatory_area":"Kod odpadów podany według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Materiały i surowce budowlane, Odpady O) kod: 10 01 01, 10 01 02 Stężenie aktywności radionuklidu: 226 Ra (z obliczeń) Poradnik ITB nr 455/2010 | PB-01 edycja 1 z dnia 24.02.2021 Materialy i surowce budowlane, Odpady O) kod: 10 01 01, 10 01 02 Stezenie aktywnosci radionuklidu: 226 Ra (z obliczen) Poradnik ITB nr 455/2010 | PB-01 edycja 1 z dnia 24.02.2021","categories":["materials","environment","construction"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a841f7baf14b9c0e7b214dc","lab_id":"69ad52a3de79e566650fb185","country":"PL","accr_number":"AB 251","accr_body":"PCA","test_object":"Materiały i surowce budowlane, Odpady O) kod: 10 01 01, 10 01 02","methodology":"Stężenie aktywności radionuklidu: 232 Th (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie aktywności radionuklidu: 232 Th (z obliczeń)","reference":"Poradnik ITB nr 455/2010 | PB-01 edycja 1 z dnia 24.02.2021","norm_bases":["Poradnik ITB nr 455/2010","PB-01 edycja 1 z dnia 24.02.2021"],"lab_section":"Laboratorium Badawcze Materiałów Budowlanych Spółka z o.o.","lab_address":null,"regulatory_area":"Kod odpadów podany według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Materiały i surowce budowlane, Odpady O) kod: 10 01 01, 10 01 02 Stężenie aktywności radionuklidu: 232 Th (z obliczeń) Poradnik ITB nr 455/2010 | PB-01 edycja 1 z dnia 24.02.2021 Materialy i surowce budowlane, Odpady O) kod: 10 01 01, 10 01 02 Stezenie aktywnosci radionuklidu: 232 Th (z obliczen) Poradnik ITB nr 455/2010 | PB-01 edycja 1 z dnia 24.02.2021","categories":["materials","environment","construction"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a841f7baf14b9c0e7b214dd","lab_id":"69ad52a3de79e566650fb185","country":"PL","accr_number":"AB 251","accr_body":"PCA","test_object":"Materiały i surowce budowlane, Odpady O) kod: 10 01 01, 10 01 02","methodology":"Wskaźnik stężenia promieniotwórczego I (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik stężenia promieniotwórczego I (z obliczeń)","reference":"Poradnik ITB nr 455/2010 | PB-01 edycja 1 z dnia 24.02.2021","norm_bases":["Poradnik ITB nr 455/2010","PB-01 edycja 1 z dnia 24.02.2021"],"lab_section":"Laboratorium Badawcze Materiałów Budowlanych Spółka z o.o.","lab_address":null,"regulatory_area":"Kod odpadów podany według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Materiały i surowce budowlane, Odpady O) kod: 10 01 01, 10 01 02 Wskaźnik stężenia promieniotwórczego I (z obliczeń) Poradnik ITB nr 455/2010 | PB-01 edycja 1 z dnia 24.02.2021 Materialy i surowce budowlane, Odpady O) kod: 10 01 01, 10 01 02 Wskaznik stezenia promieniotworczego I (z obliczen) Poradnik ITB nr 455/2010 | PB-01 edycja 1 z dnia 24.02.2021","categories":["materials","environment","construction"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Activity concentration index I (calculated)","search_en":"Activity concentration index I (calculated) Poradnik ITB nr 455/2010 | PB-01 edycja 1 z dnia 24.02.2021","methodology_zh":"放射性浓度指数 I（计算得出）","search_zh":"放射性浓度指数 I（计算得出） Poradnik ITB nr 455/2010 | PB-01 edycja 1 z dnia 24.02.2021"}],"has_pdf":true}